Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Kodiak1_raw_data
SDR 4.28.3 -----Logger Information----- Model # Serial # 7309 Hardware Rev. 009-009-000 -----Site Information----- Site # 7309 Site Desc Kodiak 1 Project Code Project Desc 100' NRG Tall Tower, tubular tilt-up, Pillar Mtn Site Location www.akenergyauthority.org Site Elevation 300 Latitude N 057° 47.008' Longitude W 152° 27.464' Time offset (hrs) -----Sensor Information----- Channel # 1 Type 1 Description NRG #40 Anem. m/s Details boom orientation: east Serial Number SN: Height 30 m Scale Factor 0.765 Offset 0.35 Units m/s Channel # 2 Type 1 Description NRG #40 Anem. m/s Details boom orientation: south Serial Number SN: Height 30 m Scale Factor 0.765 Offset 0.35 Units m/s Channel # 3 Type 1 Description NRG #40 Anem. m/s Details boom orientation: southeast Serial Number SN: Height 20 m Scale Factor 0.765 Offset 0.35 Units m/s Channel # 4 Type 0 Description No SCM Installed Details Serial Number -------- Height ------ Scale Factor 0 Offset 0 Units ----- Channel # 5 Type 0 Description No SCM Installed Details Serial Number -------- Height ------ Scale Factor 0 Offset 0 Units ----- Channel # 6 Type 0 Description No SCM Installed Details Serial Number -------- Height ------ Scale Factor 0 Offset 0 Units ----- Channel # 7 Type 3 Description #200P Wind Vane Details boom orientation: NNW Serial Number SN: Height 30 m Scale Factor 0.351 Offset 165 Units deg Channel # 8 Type 0 Description No Sensor Details Serial Number SN: Height 0 Scale Factor 0 Offset 0 Units Channel # 9 Type 4 Description NRG #110S Temp C Details Serial Number SN: Height 2 m Scale Factor 0.138 Offset -86.383 Units C Channel # 10 Type 0 Description No SCM Installed Details Serial Number -------- Height ------ Scale Factor 0 Offset 0 Units ----- Channel # 11 Type 0 Description No SCM Installed Details Serial Number -------- Height ------ Scale Factor 0 Offset 0 Units ----- Channel # 12 Type 0 Description No SCM Installed Details Serial Number -------- Height ------ Scale Factor 0 Offset 0 Units ----- Date & Time Stamp CH1Avg CH1SD CH1Max CH1Min CH2Avg CH2SD CH2Max CH2Min CH3Avg CH3SD CH3Max CH3Min CH4Avg CH4SD CH4Max CH4Min CH5Avg CH5SD CH5Max CH5Min CH6Avg CH6SD CH6Max CH6Min CH7Avg CH7SD CH7Max CH7Min CH8Avg CH8SD CH8Max CH8Min CH9Avg CH9SD CH9Max CH9Min CH10Avg CH10SD CH10Max CH10Min CH11Avg CH11SD CH11Max CH11Min CH12Avg CH12SD CH12Max CH12Min 11/02/2005 13:30:00 2.6 4.9 14.9 0.4 0.4 0.1 2.6 0.4 9 6.1 16.4 0.4 165 0 165 165 -86.4 0 -86.4 -86.4 11/02/2005 13:40:00 13.9 1.5 17.2 9.5 12.8 3.8 16.8 0.4 13.4 1.6 16.8 9.1 264 76 320 165 -86.4 0 -86.4 -86.4 11/02/2005 13:50:00 14.4 1.3 17.6 11.1 14.2 1.3 17.2 11.1 13.9 1.5 17.2 9.5 322 7 312 165 -8.3 36.9 54.9 -86.4 11/02/2005 14:00:00 13.8 1.5 17.2 9.5 13.7 1.5 16.8 9.9 13.2 1.7 17.2 9.1 319 6 316 165 4.1 0.1 4.5 3.5 11/02/2005 14:10:00 13.1 1.2 16.1 10.3 13 1.2 15.6 9.9 12.3 1.2 14.9 9.1 320 9 315 165 4.2 0 4.5 3.8 11/02/2005 14:20:00 13.7 1.5 17.6 10.3 13.6 1.5 17.2 10.3 13.4 1.6 18.3 9.5 322 7 324 165 4.1 0.1 4.5 3.8 11/02/2005 14:30:00 14.6 1.2 17.6 10.7 14.5 1.2 17.2 11.1 14 1.6 17.9 9.1 320 7 319 165 4.1 0.1 4.3 3.8 11/02/2005 14:40:00 13.9 1.2 17.6 9.9 13.8 1.2 17.2 10.3 13.7 1.3 17.9 9.9 324 6 325 165 4.2 0 4.5 3.8 11/02/2005 14:50:00 13.9 1.5 17.2 10.3 13.8 1.5 16.8 10.3 13.4 1.7 17.6 9.1 323 9 310 165 4.1 0.1 4.5 3.8 11/02/2005 15:00:00 13.7 1.2 17.6 10.3 13.6 1.2 17.6 9.9 13.3 1.4 16.4 9.5 321 7 317 165 4.1 0.2 4.5 3.5 11/02/2005 15:10:00 13.5 1.2 17.6 10.3 13.4 1.2 17.2 9.9 13 1.3 17.6 8.8 319 8 295 165 4 0.1 4.3 3.5 11/02/2005 15:20:00 12.5 1.5 15.3 8 12.5 1.5 15.6 8.4 11.8 1.7 16.1 5.7 315 8 314 165 3.9 0 4.3 3.3 11/02/2005 15:30:00 10.7 1.3 14.9 6.8 10.6 1.3 14.9 7.2 10.1 1.3 14.5 6.5 319 9 323 165 3.9 0.1 4.3 3.3 11/02/2005 15:40:00 10.4 1 13.3 8 10.3 1 13.3 8 9.9 1 13 6.8 323 10 310 165 3.7 0.3 4.3 2.8 11/02/2005 15:50:00 10.4 1.4 16.1 7.6 10.3 1.4 15.6 7.2 9.8 1.4 15.3 6.8 325 11 313 165 3.2 0.2 3.5 2.6 11/02/2005 16:00:00 11 1 13.7 8.4 10.9 1.1 14.1 8.4 10.1 1.1 13.3 7.2 315 8 307 165 3 0.2 3.3 2.3 11/02/2005 16:10:00 9.9 1 13 7.2 9.8 1 13 6.8 9.2 1 13 6.5 322 10 316 165 2.8 0 3 2.1 11/02/2005 16:20:00 10.3 1.1 13.3 7.2 10.2 1.2 13.3 7.2 9.8 1.3 14.1 6.8 325 11 325 165 2.8 0 2.8 2.1 11/02/2005 16:30:00 9.4 1.2 13.7 6.5 9.3 1.1 13 6.5 8.8 1.2 12.6 6.1 323 11 335 165 2.7 0.1 3 2.6 11/02/2005 16:40:00 9.9 1.3 13.7 6.5 9.8 1.4 13.7 6.8 9.4 1.4 13.7 5.7 333 12 339 165 2.6 0 2.8 2.1 11/02/2005 16:50:00 9.9 1.3 13 6.1 9.3 1.6 13 6.1 9.7 1.3 13.7 4.9 342 12 342 165 2.6 0 2.8 2.6 11/02/2005 17:00:00 10.3 1.2 14.5 6.8 10.3 1.2 13.7 6.8 10.1 1.3 13.7 6.8 327 12 325 165 2.7 0 2.8 2.6 11/02/2005 17:10:00 11.3 1.4 15.3 7.6 11.3 1.5 15.3 7.6 10.8 1.7 15.3 6.5 324 12 325 165 2.8 0 3 2.6 11/02/2005 17:20:00 12.1 1.5 16.8 8 12 1.5 16.4 8.4 11.7 1.6 16.1 7.6 322 9 317 165 2.7 0 2.8 2.6 11/02/2005 17:30:00 12 1.5 16.1 7.2 11.9 1.5 15.6 7.2 11.6 1.5 15.6 7.2 320 8 318 165 2.6 0 2.8 2.6 11/02/2005 17:40:00 13 1.3 17.9 10.3 12.9 1.3 17.9 9.9 12.3 1.5 17.9 8.8 318 9 307 165 2.7 0 3 2.3 11/02/2005 17:50:00 12.4 1.7 16.8 8.4 12.4 1.7 17.6 8 12.1 1.8 17.2 7.6 321 9 325 165 2.8 0 3 2.6 11/02/2005 18:00:00 13.1 2 19.9 7.2 13 2 19.5 7.6 12.8 2 19.5 7.6 323 9 316 165 2.8 0 3 2.6 11/02/2005 18:10:00 13.1 1.6 17.6 9.1 13.1 1.6 17.6 9.1 11.8 1.9 16.4 8 313 9 299 165 2.9 0.1 3 2.6 11/02/2005 18:20:00 11.6 1.4 16.1 7.6 11.5 1.5 16.1 6.8 10.8 1.5 15.3 5.7 317 9 309 165 2.9 0 3 2.3 11/02/2005 18:30:00 11.9 1.7 16.4 7.2 11.9 1.7 16.1 8 11.2 1.8 15.3 6.8 316 10 304 165 2.9 0.1 3.3 2.3 11/02/2005 18:40:00 11.6 1 16.1 9.1 11.6 1.1 16.1 9.1 10.7 1.2 14.9 7.2 317 10 316 165 2.9 0.1 3 2.3 11/02/2005 18:50:00 12.5 1.7 17.6 8 12.5 1.7 17.2 8 12.2 1.9 17.6 8.4 323 9 330 165 2.8 0 3 2.3 11/02/2005 19:00:00 10.5 1.2 14.1 8 10.4 1.2 14.1 7.6 10.1 1.2 14.1 6.5 324 9 331 165 2.7 0.1 2.8 2.1 11/02/2005 19:10:00 10.7 1.1 14.5 8 10.7 1.1 14.1 8 9.8 1.3 13 7.2 313 7 312 165 2.6 0 2.8 2.3 11/02/2005 19:20:00 11.1 1.2 13.7 6.8 11.1 1.2 13.7 7.2 10.6 1.2 14.9 7.2 317 9 313 165 2.5 0.1 2.8 2.3 11/02/2005 19:30:00 11.2 1.2 13.7 8 11.1 1.2 13.7 8 10.7 1.2 14.5 6.8 321 9 325 165 2.4 0 2.6 2.3 11/02/2005 19:40:00 12.7 1.5 16.8 9.1 12.6 1.5 16.8 8.8 12.4 1.6 16.4 8.4 322 9 307 165 2.5 0 2.8 2.3 11/02/2005 19:50:00 12.4 1.1 15.6 9.1 12.3 1.1 15.6 9.5 12 1.1 15.6 8.4 326 10 315 165 2.4 0 2.6 2.3 11/02/2005 20:00:00 12.8 1.9 17.2 8.8 12.7 1.9 17.2 8.8 12.2 1.8 16.8 7.6 326 13 323 165 2.4 0.1 2.8 2.3 11/02/2005 20:10:00 12.4 1.3 16.1 9.5 12.4 1.3 16.1 8.8 12.3 1.3 16.1 9.1 323 9 314 165 2.4 0 2.6 2.3 11/02/2005 20:20:00 11.2 1.5 15.6 7.6 11.2 1.5 15.3 6.1 10.8 1.6 14.9 7.2 325 11 317 165 2.4 0 2.6 2.3 11/02/2005 20:30:00 10.3 1.3 13.7 5.7 10.2 1.4 13.3 6.1 10 1.5 14.5 6.5 323 9 339 165 2.2 0 2.6 1.8 11/02/2005 20:40:00 11 1.3 14.9 8.4 10.9 1.3 14.9 8.4 10.7 1.5 14.5 6.8 323 10 330 165 2.3 0 2.6 2.1 11/02/2005 20:50:00 11.3 1.2 14.9 7.2 11.3 1.2 14.5 7.2 10.7 1.3 14.5 6.5 319 11 317 165 2.3 0 2.6 2.1 11/02/2005 21:00:00 12.3 1.5 17.2 8.8 12.2 1.5 16.8 8.4 11.8 1.7 16.8 6.5 318 8 316 165 2.4 0 2.6 2.3 11/02/2005 21:10:00 11.9 1.3 15.3 8.8 11.8 1.3 15.3 8.8 11.6 1.3 15.6 8.4 323 8 313 165 2.4 0 2.6 2.1 11/02/2005 21:20:00 11.6 1.2 15.6 9.5 11.5 1.2 15.3 9.1 11.4 1.4 16.1 8.4 324 10 330 165 2.1 0 2.3 1.6 11/02/2005 21:30:00 11.8 1.1 14.9 8.8 11.7 1.1 14.5 8.8 11.6 1.1 14.9 8.4 322 8 326 165 2.3 0 2.6 1.8 11/02/2005 21:40:00 10.7 1.1 13.3 7.6 10.6 1.1 13.7 7.2 10.3 1.1 13.7 7.6 322 9 322 165 2.1 0 2.6 1.6 11/02/2005 21:50:00 10.1 1 12.6 7.2 10 1 13 7.2 9.9 1.1 13.3 6.5 328 9 327 165 2 0.2 2.3 1.4 11/02/2005 22:00:00 9.5 1.1 13 7.2 9.4 1.1 13 7.2 9 1.2 13 6.1 323 10 319 165 1.9 0.1 2.1 1.4 11/02/2005 22:10:00 10 1.1 12.6 6.8 9.9 1.1 12.6 6.5 9.6 1.2 13 6.5 322 10 322 165 2 0.1 2.3 1.4 11/02/2005 22:20:00 12.1 1.5 17.2 8.4 12 1.4 16.8 8.4 11.3 1.5 16.8 7.6 320 10 323 165 2.2 0.2 2.6 1.8 11/02/2005 22:30:00 11.5 1.2 15.3 8.4 11.4 1.2 15.3 8.4 11.1 1.3 15.3 7.2 318 8 313 165 2.4 0 2.8 2.3 11/02/2005 22:40:00 11.1 1.3 14.5 7.6 10.9 1.3 14.5 7.2 10.3 1.6 14.5 6.1 316 10 331 165 2.4 0 2.8 2.3 11/02/2005 22:50:00 10.8 1.4 16.1 7.6 10.7 1.4 15.6 7.6 10.6 1.2 14.1 8 328 8 305 165 2.4 0 2.6 2.3 11/02/2005 23:00:00 11.6 1.5 17.6 8.8 11.5 1.5 16.8 8.8 11.2 1.6 16.1 7.2 326 9 315 165 2.4 0 2.6 2.3 11/02/2005 23:10:00 10.6 1.2 14.1 8 10.5 1.2 14.1 8 10.3 1.3 13.7 7.2 322 8 325 165 2.5 0 2.6 2.3 11/02/2005 23:20:00 9.7 1.1 14.5 6.8 9.6 1.1 14.5 6.8 9.3 1.3 13.7 6.5 320 9 318 165 2.4 0 2.6 2.3 11/02/2005 23:30:00 9.2 1.1 12.2 6.5 9.1 1.1 12.2 6.5 8.8 1.1 11.5 6.1 320 9 315 165 2.4 0 2.6 2.3 11/02/2005 23:40:00 9.1 0.9 11.5 6.1 9 0.9 11.5 6.5 8.9 1 12.2 6.5 323 11 302 165 2.3 0 2.6 2.3 11/02/2005 23:50:00 9.5 0.8 11.8 6.8 9.4 0.8 11.8 6.5 8.9 1 11.8 6.5 318 8 310 165 2.3 0 2.3 1.8 11/03/2005 00:00:00 9.7 1 14.5 7.2 9.7 1 14.5 6.5 9.1 1.2 12.6 6.5 319 11 300 165 2.3 0 2.6 2.1 11/03/2005 00:10:00 10.2 1.2 13 7.6 10.1 1.2 13 7.2 9.7 1.3 13 6.5 321 9 312 165 2.3 0 2.3 1.8 11/03/2005 00:20:00 10.2 1.3 13.3 6.5 10.1 1.3 13.7 6.1 9.7 1.3 13 6.5 320 8 318 165 2.2 0 2.3 2.1 11/03/2005 00:30:00 11.4 1.5 16.1 8 11.3 1.5 16.4 7.2 10.7 1.4 14.9 6.8 321 12 308 165 2.3 0 2.6 2.1 11/03/2005 00:40:00 11 1.1 14.1 8.8 10.9 1.2 14.9 8.4 10.3 1.4 15.3 6.5 318 10 308 165 2.4 0 2.6 2.1 11/03/2005 00:50:00 10.1 1.1 12.6 6.5 10 1.1 12.2 6.8 9.5 1 12.2 6.8 318 7 314 165 2.3 0 2.6 2.1 11/03/2005 01:00:00 10.4 1.5 14.1 6.5 10.4 1.5 14.1 6.1 10.1 1.4 15.6 6.5 320 10 320 165 2.3 0 2.6 2.1 11/03/2005 01:10:00 10.7 1.3 14.1 6.8 10.7 1.3 14.1 6.5 10.3 1.5 14.1 6.8 320 10 308 165 2.4 0 2.6 2.3 11/03/2005 01:20:00 10.4 1.2 14.1 7.6 10.3 1.2 14.5 8 9.8 1.3 13.7 6.5 318 8 316 165 2.4 0 2.6 2.1 11/03/2005 01:30:00 9 1.2 12.2 5.7 8.9 1.1 12.6 5.7 8.4 1.3 11.8 4.6 318 12 317 165 2.3 0 2.6 2.3 11/03/2005 01:40:00 7.9 1.1 11.5 5.3 7.9 1.1 11.8 5.7 7.5 1.1 10.7 5.3 321 8 307 165 2.1 0 2.3 2.1 11/03/2005 01:50:00 8.7 1.5 13 5.7 8.6 1.5 12.6 5.7 7.9 1.3 11.8 4.9 318 12 297 165 2.1 0 2.6 1.8 11/03/2005 02:00:00 9 1.2 12.2 6.1 8.9 1.2 12.6 5.7 8.3 1 12.6 5.3 318 10 320 165 2.3 0 2.8 2.1 11/03/2005 02:10:00 9.3 1.7 14.1 5.3 9.2 1.7 14.5 5.3 8.5 1.6 12.6 4.6 318 11 312 165 2.3 0.1 2.6 1.8 11/03/2005 02:20:00 9.8 1.4 12.6 6.5 9.7 1.5 13 6.1 9.3 1.7 12.6 5.7 321 13 301 165 2.3 0 2.6 2.1 11/03/2005 02:30:00 8 0.8 9.9 6.1 8 0.8 9.9 6.1 7.6 0.8 9.9 5.3 317 9 319 165 2.1 0 2.3 1.8 11/03/2005 02:40:00 7.8 1.3 12.2 4.9 7.5 1.3 11.8 3.8 7.5 1.2 11.8 4.9 337 13 5 165 1.9 0 2.6 1.8 11/03/2005 02:50:00 8.9 1.3 13.3 6.5 8.7 1.4 13 5.7 8.5 1.4 12.6 5.7 325 13 312 165 1.9 0 2.3 1.8 11/03/2005 03:00:00 9.4 1.2 12.6 6.8 9.3 1.2 11.8 6.8 8.9 1.2 12.2 6.1 319 8 315 165 1.8 0 1.8 1.6 11/03/2005 03:10:00 10.6 1.4 14.5 6.8 10.6 1.4 14.9 6.5 10.4 1.4 13.7 6.5 323 9 315 165 1.8 0 2.1 1.6 11/03/2005 03:20:00 9.9 1.2 13 7.2 9.8 1.2 13 6.8 9.4 1.1 13 6.1 322 9 309 165 1.7 0 2.1 1.6 11/03/2005 03:30:00 8.8 1.3 12.6 5.7 8.7 1.3 12.2 5.3 8.4 1.3 12.2 5.7 328 12 333 165 1.4 0.1 1.8 1.4 11/03/2005 03:40:00 9.3 1.3 12.6 6.5 9.1 1.5 13 4.9 8.7 1.2 12.6 5.7 330 17 343 165 1.4 0 1.6 1.4 11/03/2005 03:50:00 11.8 1.5 16.4 5.7 11.8 1.5 16.1 5.7 11.1 1.7 14.9 5.7 320 11 312 165 1.5 0 1.8 1.4 11/03/2005 04:00:00 13.2 2.1 21.4 8.8 13.1 2.1 21 8.4 12.1 2.1 19.9 8 318 12 306 165 1.8 0 1.8 1.4 11/03/2005 04:10:00 11.1 1.9 17.2 6.8 11.1 1.9 16.8 6.5 10.5 1.7 16.1 6.5 322 10 312 165 1.7 0 1.8 1.4 11/03/2005 04:20:00 13 1.5 18.3 9.1 12.9 1.6 17.9 8.8 12.5 1.7 18.7 8 322 8 327 165 1.6 0 1.8 1.4 11/03/2005 04:30:00 12 1.3 14.5 8 11.9 1.2 14.5 8.4 11.8 1.2 14.5 8.4 323 7 326 165 1.4 0.1 1.8 1.4 11/03/2005 04:40:00 11.6 1.1 14.9 8.4 11.5 1.2 14.9 8.4 10.9 1 14.9 8 317 8 311 165 1.2 0 1.4 1.1 11/03/2005 04:50:00 11.3 1.3 14.9 8 11.2 1.2 14.9 7.6 10.7 1.3 14.5 7.6 320 9 311 165 1.2 0 1.4 0.9 11/03/2005 05:00:00 11.1 1.2 14.1 6.5 11 1.2 14.1 6.8 10.6 1.2 14.1 6.1 318 6 315 165 1 0.1 1.4 0.9 11/03/2005 05:10:00 11.6 1 14.1 8.8 11.5 1 14.1 8 11 1.3 14.1 6.8 317 6 305 165 0.9 0 1.1 0.7 11/03/2005 05:20:00 11.7 1 14.1 9.1 11.6 1 14.1 9.1 11 1.1 13.3 7.6 316 6 311 165 0.9 0 1.1 0.7 11/03/2005 05:30:00 12.4 0.8 14.9 10.3 12.4 0.8 14.9 10.3 11.9 1 14.1 8 318 6 315 165 0.9 0 1.1 0.9 11/03/2005 05:40:00 12.6 1 15.3 9.9 12.5 1 14.9 9.5 12.1 1.1 14.9 9.1 317 5 328 165 1 0 1.1 0.9 11/03/2005 05:50:00 11.8 1 14.9 9.1 11.7 1.1 14.5 9.1 10.9 1.3 14.5 6.8 314 7 312 165 0.9 0.1 1.4 0.9 11/03/2005 06:00:00 11.6 1 14.5 9.1 11.5 1 14.1 9.5 10.8 1.3 14.5 7.6 318 8 318 165 0.9 0 1.1 0.7 11/03/2005 06:10:00 11 1 13.7 8 10.9 1 13.7 8.4 10.8 1 14.5 8.4 320 7 317 165 1 0 1.4 0.9 11/03/2005 06:20:00 11.7 1.2 14.9 8.4 11.5 1.2 14.9 8 10.4 1.1 14.1 6.8 312 8 302 165 1.1 0 1.4 0.9 11/03/2005 06:30:00 12.7 1.2 15.3 9.1 12.6 1.2 15.3 9.1 11.8 1.2 14.5 8.4 315 7 308 165 1.3 0.1 1.4 0.9 11/03/2005 06:40:00 12.6 1.4 17.2 9.5 12.5 1.4 16.8 9.5 11.6 1.4 14.9 8 314 6 310 165 1.2 0 1.4 1.1 11/03/2005 06:50:00 13.1 1.5 16.8 8.8 13.1 1.4 16.8 9.1 12.2 1.5 17.2 8.4 316 8 319 165 1.3 0 1.4 1.4 11/03/2005 07:00:00 11.9 1.2 15.3 8 11.8 1.2 15.6 8.8 11.5 1.3 15.6 8.4 319 7 318 165 1.2 0 1.4 0.9 11/03/2005 07:10:00 12 1.7 16.8 8.4 11.9 1.6 16.8 8.4 11.7 1.5 15.6 8.4 326 9 330 165 1.2 0 1.4 0.9 11/03/2005 07:20:00 12.5 1.4 17.2 8.8 12.4 1.4 16.8 8.8 12.2 1.5 17.2 7.6 327 10 323 165 1.3 0 1.4 0.9 11/03/2005 07:30:00 12.4 1.4 16.1 8 12.4 1.4 16.4 8 12.1 1.6 17.9 7.2 323 9 313 165 1.4 0 1.6 1.1 11/03/2005 07:40:00 12.1 2.2 17.9 6.5 12.1 2.2 17.6 7.2 11.5 2.3 17.2 6.1 321 12 318 165 1.4 0 1.6 1.4 11/03/2005 07:50:00 11.7 1.4 17.9 8 11.7 1.4 17.6 7.6 10.9 1.5 16.4 6.8 317 10 321 165 1.4 0 1.4 1.4 11/03/2005 08:00:00 12.5 1.5 17.6 9.5 12.4 1.5 17.2 7.6 12 1.5 16.1 8 321 12 316 165 1.4 0 1.6 1.1 11/03/2005 08:10:00 15.4 2.1 20.2 10.3 15.3 2.1 20.2 9.9 14.9 2.3 20.6 9.5 320 9 314 165 1.5 0 1.6 1.4 11/03/2005 08:20:00 12.4 1.7 16.4 7.6 12.3 1.7 16.1 7.2 11.9 1.8 17.2 8 324 11 328 165 1.3 0 1.6 1.1 11/03/2005 08:30:00 11.3 1.2 14.9 8.4 11.3 1.2 14.9 8.4 11 1.1 14.9 8.8 322 11 330 165 1 0.1 1.6 0.9 11/03/2005 08:40:00 12.3 1.2 15.6 9.9 12.2 1.2 16.1 9.5 11.4 1.3 16.4 8.4 315 9 320 165 1.1 0 1.4 0.9 11/03/2005 08:50:00 11.9 1.6 17.2 7.2 11.8 1.6 16.8 7.6 10.9 1.9 16.8 6.5 313 7 333 165 1.4 0 1.6 1.1 11/03/2005 09:00:00 13.2 1.6 17.6 8.8 13.2 1.6 17.6 9.1 12.2 1.7 17.6 6.8 317 11 310 165 1.5 0 1.8 1.4 11/03/2005 09:10:00 12.2 2.3 17.9 6.8 12.1 2.4 17.9 6.5 11.6 2.2 16.8 6.5 324 13 313 165 1.7 0 1.8 1.6 11/03/2005 09:20:00 13.7 1.7 18.7 7.6 13.6 1.7 18.3 8 13.1 1.9 16.8 8.4 323 13 302 165 1.8 0 1.8 1.6 11/03/2005 09:30:00 13.6 1.9 20.2 9.1 13.4 2 20.6 8.4 13.5 1.7 20.2 10.3 329 12 340 165 1.7 0.1 1.8 1.6 11/03/2005 09:40:00 12.3 1.5 17.2 6.5 12.2 1.5 17.2 6.8 11.7 1.7 17.6 6.5 320 11 323 165 1.7 0 1.8 1.6 11/03/2005 09:50:00 10.8 1.3 13.7 5.7 10.7 1.4 13.7 5.3 9.7 1.3 13 6.1 323 20 300 165 1.4 0 1.6 1.1 11/03/2005 10:00:00 11.9 1.5 16.1 8 11.8 1.5 16.1 7.6 11.3 1.6 14.9 7.2 322 11 317 165 1.5 0.1 1.8 0.9 11/03/2005 10:10:00 12.7 2.6 22.9 7.6 12.6 2.6 22.6 7.6 12 2.5 20.2 7.6 322 11 306 165 1.3 0 1.4 1.1 11/03/2005 10:20:00 15.1 2.6 23.3 8.8 15 2.7 23.3 8.4 14.3 2.3 22.9 8 321 13 325 165 1.1 0 1.4 0.9 11/03/2005 10:30:00 15.2 1.5 20.6 12.2 15.1 1.6 20.2 11.8 14.7 1.8 21.8 10.7 325 11 341 165 1.1 0 1.4 0.9 11/03/2005 10:40:00 16.3 2.4 22.6 10.7 16.1 2.5 22.6 9.9 15.6 2.5 25.2 10.3 325 11 316 165 1.1 0.1 1.4 0.9 11/03/2005 10:50:00 15.8 2.2 22.9 10.7 15.7 2.2 22.9 10.7 15 2.2 22.1 8.8 319 9 297 165 1.3 0 1.6 1.1 11/03/2005 11:00:00 14.1 1.7 20.2 10.3 13.8 1.7 19.9 9.9 13.3 2 19.1 8.8 326 15 346 165 1.2 0 1.6 1.1 11/03/2005 11:10:00 13.6 1.7 19.1 8.4 13.5 1.7 18.7 8.4 12.9 2 17.9 8 320 11 307 165 1.4 0 1.6 1.4 11/03/2005 11:20:00 16.9 2 22.6 12.6 16.8 2 22.1 12.6 16.2 2.2 21.8 11.5 318 8 316 165 1.2 0 1.4 1.1 11/03/2005 11:30:00 16.9 1.6 21 12.6 16.8 1.6 20.6 12.6 16.4 1.7 21.4 11.8 320 8 309 165 1.1 0 1.4 0.9 11/03/2005 11:40:00 16.3 2.5 22.6 11.8 16.2 2.5 22.1 11.5 15.1 1.7 19.5 10.7 318 11 305 165 1.2 0.1 1.4 0.9 11/03/2005 11:50:00 16.9 1.7 22.9 12.6 16.9 1.7 22.6 12.6 16.2 1.7 20.2 11.1 317 9 310 165 0.9 0 1.4 0.7 11/03/2005 12:00:00 16.6 1.7 22.1 12.6 16.5 1.7 21.4 12.6 15.5 2.2 20.6 10.7 316 9 326 165 1.1 0 1.4 0.9 11/03/2005 12:10:00 16.1 1.4 19.5 12.2 16.1 1.4 19.5 11.5 15 1.5 18.7 10.7 315 7 310 165 1.1 0 1.4 0.9 11/03/2005 12:20:00 17.3 1.6 20.6 13.3 17.2 1.5 20.6 13.7 15.1 1.7 19.9 10.7 310 6 302 165 1.1 0 1.4 0.9 11/03/2005 12:30:00 18.9 2 24 13.3 18.8 2 23.7 13 17.7 2.1 23.3 11.8 315 6 304 165 1.1 0 1.4 0.9 11/03/2005 12:40:00 21 1.7 24.8 16.4 20.8 1.7 24.4 16.1 20.4 1.9 25.2 15.3 318 6 313 165 1.1 0 1.4 0.9 11/03/2005 12:50:00 18.3 1.6 22.9 13.3 18.2 1.6 22.6 13 17.7 1.9 26 13 318 7 318 165 1.1 0 1.4 0.9 11/03/2005 13:00:00 17.9 2.3 23.3 11.5 17.7 2.5 23.7 11.5 16.6 2.4 23.3 11.5 320 15 311 165 1.4 0 1.6 1.1 11/03/2005 13:10:00 17.1 2.1 23.3 11.8 16.9 2.1 22.9 12.2 15.5 2.5 24 9.5 311 10 323 165 1.3 0 1.4 0.9 11/03/2005 13:20:00 18 2 24 11.1 17.9 2 23.3 11.5 17.4 2.3 22.6 9.9 323 12 335 165 1.4 0 1.6 1.1 11/03/2005 13:30:00 17.8 2.2 23.7 11.1 17.8 2.2 23.3 11.5 17 2.3 24 11.5 319 9 307 165 1.4 0 1.4 1.4 11/03/2005 13:40:00 18.3 2.6 24 11.1 18.1 2.6 24 11.5 17.5 2.5 24 9.9 321 9 312 165 1.3 0 1.6 1.1 11/03/2005 13:50:00 18.8 2.5 26 12.6 18.7 2.5 25.6 13.3 18 2.6 25.2 11.8 319 8 322 165 1.1 0 1.4 0.9 11/03/2005 14:00:00 22.2 2.6 27.9 12.6 22 2.5 27.5 13 22 2.6 26.8 15.3 320 7 317 165 0.8 0 0.9 0.7 11/03/2005 14:10:00 20 1.9 24.8 14.5 19.9 1.9 24.8 14.5 19 2 23.7 13.3 318 10 305 165 0.7 0 0.9 0.2 11/03/2005 14:20:00 18.6 1.9 23.3 13.3 18.5 1.9 23.3 13 17.9 2.3 22.6 11.1 317 8 321 165 0.4 0 0.7 0.2 11/03/2005 14:30:00 15.7 1.9 22.9 9.9 15.6 1.8 22.1 10.3 14.5 1.9 21.8 9.9 316 11 306 165 0.3 0 0.7 0.2 11/03/2005 14:40:00 14.4 2.1 19.5 9.1 14.3 2 19.9 9.5 12.9 1.8 17.6 7.6 313 13 283 165 0.4 0.1 0.7 0.2 11/03/2005 14:50:00 14.3 2.5 20.2 9.1 14.2 2.5 20.6 8.8 13.1 1.9 19.1 8.8 316 11 307 165 0.3 0 0.7 0.2 11/03/2005 15:00:00 15.5 2.1 20.6 10.7 15.5 2 20.6 10.3 14.5 2.2 19.9 9.1 317 10 305 165 0.2 0.1 0.7 -0.1 11/03/2005 15:10:00 15.5 1.7 20.2 10.7 15.4 1.7 19.9 10.7 14.1 1.9 19.1 7.6 314 9 296 165 -0.1 0 0.2 -0.3 11/03/2005 15:20:00 14.4 2 20.6 8.4 14.3 1.9 21 9.1 13.2 1.9 18.3 8.8 313 11 301 165 -0.2 0 -0.1 -0.5 11/03/2005 15:30:00 15.2 1.9 21.4 11.1 15 1.9 21.4 11.1 14.2 1.9 19.5 9.9 317 11 313 165 -0.3 0 -0.1 -0.5 11/03/2005 15:40:00 16.6 2 23.7 11.8 16.5 2 23.3 11.5 15.3 2.1 22.1 10.3 314 9 297 165 -0.6 0 -0.5 -0.8 11/03/2005 15:50:00 18.1 2.2 24.4 13 18 2.2 24 12.6 16.9 2.2 22.9 11.1 315 9 304 165 -0.8 0 -0.5 -1 11/03/2005 16:00:00 20.1 2.2 26.8 14.5 20 2.2 26.3 14.5 19.3 2.3 25.2 13.7 317 8 298 165 -0.9 0 -0.8 -1 11/03/2005 16:10:00 21.2 1.7 25.2 14.5 21 1.6 24.8 15.3 20.4 2 25.2 13.7 319 6 319 165 -0.9 0 -0.8 -1.2 11/03/2005 16:20:00 20.4 2.3 27.5 14.9 20.2 2.3 27.5 14.9 19.8 2.6 26.8 12.6 321 8 310 165 -1.1 0 -0.8 -1.2 11/03/2005 16:30:00 20.5 1.8 26.3 15.6 20.3 1.8 25.6 15.3 19.8 2.1 24.8 13.7 321 9 316 165 -1.4 0 -1.2 -1.4 11/03/2005 16:40:00 18.7 2.3 24.4 13.3 18.6 2.3 24 13.3 18.1 2.2 22.9 12.2 323 10 310 165 -1.6 0 -1.4 -1.7 11/03/2005 16:50:00 19.4 2.6 26 14.1 19.2 2.6 26 13.7 18.8 2.6 25.2 13 321 9 308 165 -1.8 0 -1.4 -1.9 11/03/2005 17:00:00 20.2 1.7 25.2 15.3 20 1.7 25.2 15.3 19.6 2.1 25.2 13.7 320 7 317 165 -2 0 -1.9 -2.1 11/03/2005 17:10:00 20.3 2.4 28.3 12.2 20.1 2.4 27.9 12.6 19.5 2.4 25.2 12.2 319 8 307 165 -2.4 0.1 -2.1 -2.6 11/03/2005 17:20:00 23.8 2.2 29.4 16.8 23.6 2.2 29.1 17.2 23.6 2.4 28.7 15.6 322 7 316 165 -2.6 0 -2.1 -2.8 11/03/2005 17:30:00 20.4 2.3 26.3 14.1 20.3 2.3 27.5 15.3 19.8 2.5 25.6 13 318 8 307 165 -3 0.1 -2.6 -3.3 11/03/2005 17:40:00 17.5 2.3 24.4 9.9 17.4 2.3 24 9.1 16.4 2.2 22.1 10.3 319 11 302 165 -3.3 0 -3 -3.5 11/03/2005 17:50:00 17.6 2.3 25.2 13 17.5 2.3 25.2 13 16.5 2.6 25.2 11.5 318 11 312 165 -3.3 0.1 -2.8 -3.5 11/03/2005 18:00:00 15.5 3.2 23.7 7.6 15.4 3.2 23.3 7.2 14.2 2.9 21.4 6.5 320 14 302 165 -3.1 0 -2.8 -3.3 11/03/2005 18:10:00 13.6 2 19.9 9.1 13.5 2 19.9 9.1 12.6 2 18.7 6.8 320 10 306 165 -3.2 0 -3 -3.5 11/03/2005 18:20:00 12.5 2.2 18.3 7.2 12.4 2.2 17.9 6.8 11.3 2.1 17.2 6.8 316 15 334 165 -3.5 0 -3.3 -3.5 11/03/2005 18:30:00 13.9 2.4 22.1 8.8 13.9 2.4 22.1 8 12.5 2.2 20.2 7.6 316 12 326 165 -3.5 0.1 -3.3 -3.7 11/03/2005 18:40:00 11.2 1.8 18.3 7.2 11.1 1.8 18.3 7.2 10.5 2.1 17.9 6.8 324 15 341 165 -3.9 0 -3.5 -4.2 11/03/2005 18:50:00 10.2 1.9 15.6 6.5 9.6 1.9 15.6 5.7 9.9 2.3 15.6 4.6 340 13 349 165 -4.5 0.1 -4.2 -4.6 11/03/2005 19:00:00 10.3 2 15.6 5.3 9.6 2.1 16.4 5.7 9.7 2.1 15.6 4.9 337 21 338 165 -4.6 0 -4.4 -4.6 11/03/2005 19:10:00 6.1 1.7 10.7 2.6 6 1.7 10.7 2.3 5.5 1.8 10.7 1.5 318 19 327 165 -4.7 0.1 -4.4 -5 11/03/2005 19:20:00 6.4 2.3 11.8 0.4 5.7 1.8 11.5 0.7 5.2 2.3 11.8 0.7 336 38 10 165 -5 0.1 -4.6 -5.3 11/03/2005 19:30:00 7 1.6 11.8 3.4 6.8 1.4 10.7 3 6.5 1.6 11.5 3.4 329 24 354 165 -4.4 0.2 -4.2 -5 11/03/2005 19:40:00 11.3 2.3 19.1 4.2 11.2 2.3 19.1 4.2 9.3 2.4 16.8 3.8 305 10 306 165 -4.4 0 -4.2 -4.6 11/03/2005 19:50:00 9.9 1.5 13.7 6.5 9.4 1.4 13 5.7 9.5 1.3 13.3 5.7 336 13 3 165 -4.3 0 -3.9 -4.6 11/03/2005 20:00:00 11.9 2.5 18.7 6.8 11.5 2.7 18.7 5.7 10.5 2.1 16.4 6.5 324 21 302 165 -4 0.1 -3.7 -4.6 11/03/2005 20:10:00 16.5 1.7 20.6 12.6 16.4 1.7 20.6 12.6 13.2 1.9 18.7 8.8 305 7 289 165 -4.3 0 -3.9 -4.6 11/03/2005 20:20:00 16.8 1.5 22.1 12.2 16.7 1.5 21.8 12.6 14.7 1.7 19.1 10.7 309 6 309 165 -4.4 0 -4.4 -4.6 11/03/2005 20:30:00 16.4 1.4 22.1 13 16.3 1.3 21.8 13.3 14.8 1.6 19.9 10.7 312 7 302 165 -4.4 0.1 -3.9 -4.6 11/03/2005 20:40:00 18 1.5 21.4 14.1 17.9 1.5 21 14.5 16.3 1.2 19.9 13.3 312 5 304 165 -4.3 0.1 -3.9 -4.6 11/03/2005 20:50:00 20.2 1.7 24 16.4 20.2 1.7 23.7 16.4 18.7 1.7 22.9 14.5 310 4 306 165 -4.5 0 -4.4 -4.6 11/03/2005 21:00:00 21.9 1.1 24.4 18.7 21.9 1.1 24.8 18.7 20.6 1.5 23.3 16.4 312 4 309 165 -4.7 0 -4.4 -4.6 11/03/2005 21:10:00 22.5 1.2 24.8 19.5 22.5 1.2 24.8 18.7 21.7 1.4 24.8 16.8 314 4 311 165 -4.6 0 -4.4 -4.8 11/03/2005 21:20:00 22.8 1.1 26 20.6 22.7 1.1 25.6 20.2 22.4 1.4 26.3 17.9 315 4 314 165 -4.4 0 -4.4 -4.6 11/03/2005 21:30:00 21.5 1.3 24 17.6 21.4 1.3 24 17.6 20.5 1.5 24.4 15.6 312 4 310 165 -4.6 0 -4.4 -4.6 11/03/2005 21:40:00 22 1.3 25.2 18.7 22 1.3 24.8 18.7 21.3 1.5 24.4 16.8 313 4 308 165 -4.7 0 -4.4 -4.6 11/03/2005 21:50:00 22.5 1.2 25.6 19.1 22.4 1.2 25.2 18.7 21.8 1.5 26 16.8 313 4 313 165 -4.4 0.3 -3.7 -4.8 11/03/2005 22:00:00 20.5 1.5 24.4 17.2 20.5 1.6 24.4 16.8 18.9 2.2 24.4 13.3 309 5 306 165 -4.2 0.3 -3.7 -4.6 11/03/2005 22:10:00 20 1.5 23.7 16.4 19.9 1.5 23.7 16.4 17.9 1.7 22.6 12.6 310 4 307 165 -4.7 0 -4.4 -4.6 11/03/2005 22:20:00 20.2 1.3 22.9 16.1 20.1 1.3 22.9 16.1 17.7 1.7 21.8 13.3 309 4 305 165 -4.7 0 -4.4 -5 11/03/2005 22:30:00 18.4 1.9 22.1 13.7 18.3 1.9 22.1 13.7 17 1.8 21 11.8 312 5 309 165 -4.7 0 -4.4 -4.8 11/03/2005 22:40:00 17.6 1.4 21.4 13.7 17.5 1.4 21.4 13.7 16.5 1.8 21 10.7 313 6 310 165 -4.8 0 -4.6 -4.8 11/03/2005 22:50:00 20.5 1.7 23.3 14.9 20.5 1.7 23.3 14.5 19.4 1.7 22.6 15.3 311 5 305 165 -4.7 0.1 -4.6 -5 11/03/2005 23:00:00 22.6 1 26 19.5 22.6 1 26 19.5 21.3 1.4 24.4 16.1 310 4 307 165 -4.7 0 -4.6 -4.8 11/03/2005 23:10:00 24 1.7 27.1 18.7 23.9 1.7 26.8 17.9 22.3 1.7 26 17.6 309 4 315 165 -4.5 0 -4.4 -4.6 11/03/2005 23:20:00 23 1.3 26.8 19.5 22.9 1.3 27.1 19.5 20.6 2.1 24.4 14.5 307 4 313 165 -4.5 0 -4.4 -4.6 11/03/2005 23:30:00 21.2 1.5 24 16.1 21.1 1.6 24 15.3 20 1.8 23.3 12.6 310 4 304 165 -4.5 0 -4.4 -4.6 11/03/2005 23:40:00 20.3 1.5 24.4 16.4 20.3 1.5 24.4 16.1 19.5 2 24.8 14.1 312 5 316 165 -4.4 0 -4.4 -4.6 11/03/2005 23:50:00 22.2 1.6 26.8 17.9 22.1 1.7 26.3 17.9 20.8 1.7 25.2 16.1 310 5 305 165 -4.2 0 -3.9 -4.6 11/04/2005 00:00:00 23.2 1.5 26 18.3 23.1 1.5 26 18.7 21.9 1.9 26 15.3 310 5 306 165 -4.4 0 -4.2 -4.6 11/04/2005 00:10:00 23 1.3 26 18.7 22.9 1.3 26 18.3 22.1 1.7 26.3 16.4 311 4 312 165 -4.7 0 -4.4 -4.6 11/04/2005 00:20:00 22.4 1.3 25.6 19.1 22.4 1.3 26 19.1 22 1.5 25.2 16.8 314 5 313 165 -4.7 0 -4.6 -5 11/04/2005 00:30:00 23.6 2.1 27.9 18.3 23.6 2.2 28.3 17.9 22.8 2.4 27.9 16.4 313 5 310 165 -4.7 0 -4.4 -4.8 11/04/2005 00:40:00 24.4 1.9 29.4 19.5 24.3 2 29.1 19.1 24.1 1.9 29.1 18.7 316 6 312 165 -4.3 0 -4.2 -4.6 11/04/2005 00:50:00 23.6 1.7 28.3 19.1 23.5 1.7 27.9 18.7 23.5 2 29.8 18.3 321 6 310 165 -4.3 0 -4.2 -4.6 11/04/2005 01:00:00 23.3 1.3 27.5 20.2 23.1 1.3 27.1 19.5 23 1.5 26.3 17.9 320 5 328 165 -4.5 0.1 -4.4 -4.8 11/04/2005 01:10:00 23.6 1.1 27.1 20.2 23.4 1.1 26.3 20.6 23.6 1.4 27.5 19.5 322 5 325 165 -4.7 0 -4.6 -4.8 11/04/2005 01:20:00 21.7 1.5 25.6 16.4 21.5 1.5 25.6 16.4 21.5 1.6 25.6 17.2 322 6 321 165 -4.7 0 -4.6 -4.8 11/04/2005 01:30:00 19.7 2.1 24 13.7 19.5 2.1 24 14.1 19.4 2.1 23.3 14.1 322 6 312 165 -4.7 0 -4.6 -5 11/04/2005 01:40:00 17.2 1.4 20.6 13 17 1.4 20.2 12.6 16.7 1.6 20.2 12.2 319 6 312 165 -4.9 0 -4.6 -5 11/04/2005 01:50:00 16.5 1.5 20.6 12.2 16.4 1.5 20.2 12.2 15.8 1.7 21 10.3 318 8 325 165 -4.8 0.1 -4.6 -5.3 11/04/2005 02:00:00 16.7 1.7 22.6 12.2 16.6 1.7 21.8 12.2 16.5 1.9 20.6 11.5 325 8 328 165 -4.4 0 -4.4 -4.6 11/04/2005 02:10:00 16 1.9 22.6 12.2 15.9 2 22.1 11.8 15.7 1.9 21.8 11.1 325 10 310 165 -4.2 0 -3.9 -4.4 11/04/2005 02:20:00 18.1 1.5 23.7 13.7 18 1.5 23.3 14.1 17.7 1.7 23.3 13.3 319 7 316 165 -4.2 0 -3.9 -4.4 11/04/2005 02:30:00 19 2.4 25.6 14.1 18.9 2.4 25.6 14.1 18 2.3 24.4 12.2 320 10 310 165 -4.2 0.1 -3.9 -4.6 11/04/2005 02:40:00 19.3 2.7 26.3 12.6 19.2 2.7 26.3 13 18.5 2.4 26.8 11.8 321 12 312 165 -3.8 0.1 -3.3 -3.9 11/04/2005 02:50:00 21 2.6 26.3 13 20.8 2.5 26.3 13 20.1 2.7 27.1 13.7 319 9 309 165 -3.1 0.1 -2.8 -3.5 11/04/2005 03:00:00 19.4 2.3 24.4 12.6 19.2 2.3 24.4 12.2 18.7 2.6 24.4 12.6 319 7 318 165 -3.3 0 -3 -3.5 11/04/2005 03:10:00 18 2.6 27.1 9.5 17.8 2.6 26.8 9.5 17.5 2.7 25.2 9.1 323 9 299 165 -3.3 0 -3 -3.5 11/04/2005 03:20:00 18.1 2.2 24.4 12.2 18 2.2 24 12.2 17.2 2.5 24 11.5 318 8 323 165 -3.3 0.1 -3 -3.5 11/04/2005 03:30:00 16.6 2.6 22.6 9.9 16.4 2.6 22.6 9.9 15.8 2.6 22.1 9.5 320 8 310 165 -3 0 -2.8 -3.5 11/04/2005 03:40:00 15.5 2.4 23.7 8.8 15.3 2.5 23.7 9.1 14.6 2.3 20.2 9.1 317 8 300 165 -3 0 -2.8 -3.3 11/04/2005 03:50:00 15.8 2.3 22.9 9.5 15.7 2.2 22.6 9.5 14.7 2.2 21.8 9.1 316 9 302 165 -2.8 0 -2.6 -3 11/04/2005 04:00:00 15.8 2.1 20.2 9.5 15.7 2.1 19.9 9.9 15 2.6 22.1 9.1 319 10 316 165 -2.8 0.1 -2.6 -3 11/04/2005 04:10:00 17.4 2.3 23.7 13 17.3 2.3 23.7 12.6 16.5 2 23.7 11.8 320 9 307 165 -3 0 -2.8 -3.3 11/04/2005 04:20:00 18.7 2.4 23.3 11.8 18.6 2.4 23.7 11.8 17.9 2.5 23.7 11.5 318 8 312 165 -3.3 0 -3 -3.5 11/04/2005 04:30:00 17 2.2 25.2 11.1 16.9 2.1 24.4 11.1 14.6 2.2 21 9.5 308 6 311 165 -3.7 0.1 -3.3 -3.9 11/04/2005 04:40:00 13.7 1.7 18.7 9.1 13.6 1.7 17.9 9.1 12 1.8 17.6 8 309 9 307 165 -4 0.1 -3.7 -4.2 11/04/2005 04:50:00 13.9 1.7 17.2 9.5 13.8 1.7 17.2 9.5 10.8 1.3 16.1 7.2 302 7 302 165 -4.2 0.1 -3.9 -4.4 11/04/2005 05:00:00 13.7 1.3 17.9 10.7 13.6 1.3 17.9 10.7 10.2 1.5 15.6 7.2 300 6 295 165 -4.2 0 -4.2 -4.4 11/04/2005 05:10:00 15.3 1.5 19.9 11.5 15.3 1.5 19.5 11.5 12.3 1.8 19.5 8.8 303 8 289 165 -4.2 0 -3.9 -4.4 11/04/2005 05:20:00 12.9 1.5 16.1 9.5 12.8 1.5 16.1 8.8 11.1 1.6 15.3 7.6 308 7 310 165 -4.3 0 -4.2 -4.4 11/04/2005 05:30:00 11.3 1.7 15.3 6.5 10.8 1.8 14.9 6.1 10.5 1.9 15.6 5.7 335 15 338 165 -4.4 0 -4.2 -4.6 11/04/2005 05:40:00 9.3 1.4 12.6 5.7 9.2 1.3 13 6.1 8.5 1.6 13.3 4.9 318 17 347 165 -4.3 0 -4.2 -4.4 11/04/2005 05:50:00 11.1 1.7 15.3 6.8 11.1 1.7 14.9 6.8 9 1.5 14.5 5.3 302 9 297 165 -4 0 -3.9 -4.4 11/04/2005 06:00:00 10.8 1.9 16.4 6.5 10.7 1.8 15.6 6.8 9 1.6 14.1 5.3 306 8 290 165 -4 0 -3.9 -4.2 11/04/2005 06:10:00 13.2 2.1 17.9 8.8 13.1 2 17.9 9.1 11.5 1.8 16.8 7.2 310 8 306 165 -4.1 0 -3.9 -4.4 11/04/2005 06:20:00 13.7 1.5 17.9 9.9 13.6 1.4 17.6 9.5 12.1 1.6 16.1 7.6 312 9 301 165 -4.2 0 -3.9 -4.4 11/04/2005 06:30:00 12.6 1.5 16.8 8.8 12.5 1.5 17.2 8.4 11.4 1.4 16.1 8 314 8 309 165 -4.3 0 -4.2 -4.4 11/04/2005 06:40:00 12.8 1.3 17.6 9.1 12.7 1.3 17.6 9.1 11.9 1.7 16.8 8 313 8 302 165 -4.3 0 -4.2 -4.6 11/04/2005 06:50:00 14.1 1.7 19.5 9.5 14 1.7 19.5 9.5 13.6 1.7 18.3 8.4 321 11 309 165 -4.3 0 -4.2 -4.6 11/04/2005 07:00:00 14.4 1.3 17.9 10.7 14.3 1.3 17.9 11.1 14 1.7 18.3 9.5 322 10 335 165 -4.3 0 -4.2 -4.6 11/04/2005 07:10:00 14.4 1.6 19.1 11.1 14.3 1.6 18.7 11.1 14.1 1.6 19.1 11.1 323 9 325 165 -4.3 0 -4.2 -4.6 11/04/2005 07:20:00 16.5 1.6 20.2 12.6 16.4 1.6 20.2 12.6 15.1 1.7 19.9 11.1 314 8 307 165 -4.4 0 -4.4 -4.6 11/04/2005 07:30:00 16.2 1.4 20.2 12.2 16.1 1.5 19.9 12.6 15.2 1.5 18.7 11.1 315 7 312 165 -4.5 0 -4.4 -4.6 11/04/2005 07:40:00 17 1.9 21.4 11.8 16.8 1.9 21 11.5 16.1 2 20.6 10.3 317 7 331 165 -4.5 0 -4.4 -4.6 11/04/2005 07:50:00 16.1 1.6 21.4 12.2 16 1.6 21 12.6 15.2 1.7 18.7 10.3 314 6 311 165 -4.4 0 -4.4 -4.6 11/04/2005 08:00:00 16.9 2 22.1 11.1 16.7 2 21.4 11.1 15.2 2 19.5 9.1 312 8 296 165 -4.5 0 -4.4 -4.6 11/04/2005 08:10:00 17.3 1.3 20.6 13.3 17.2 1.3 21 13.3 16.3 1.5 20.6 11.8 316 8 321 165 -4.5 0 -4.4 -4.6 11/04/2005 08:20:00 18.1 1.6 22.1 12.6 18 1.6 22.1 13 18 1.7 22.1 13.3 321 7 313 165 -4.6 0 -4.4 -4.8 11/04/2005 08:30:00 17.7 1.7 22.1 12.6 17.5 1.7 21.8 12.2 16.7 2 21.4 10.3 317 7 321 165 -4.7 0 -4.6 -4.8 11/04/2005 08:40:00 15.8 1.6 20.2 9.1 15.6 1.5 20.2 9.5 14.8 1.8 18.7 9.5 321 8 310 165 -4.7 0 -4.6 -4.8 11/04/2005 08:50:00 13.6 1.8 20.2 9.5 13.4 1.8 20.6 9.5 12.7 2 19.5 6.8 325 10 307 165 -4.5 0 -4.4 -4.6 11/04/2005 09:00:00 13.7 1.6 18.3 9.1 13.6 1.6 17.9 9.5 12.9 1.7 16.8 7.6 323 11 308 165 -4.3 0 -4.2 -4.6 11/04/2005 09:10:00 15.1 1.5 18.7 11.5 15 1.5 19.1 11.1 13.6 2 19.5 9.1 314 7 323 165 -4.2 0 -4.2 -4.4 11/04/2005 09:20:00 14.2 1.8 20.6 10.3 14.2 1.8 20.6 10.3 11.9 2 18.3 6.8 311 8 301 165 -4 0 -3.7 -4.4 11/04/2005 09:30:00 12.7 2.1 18.3 8.4 12.6 2.1 18.7 8.8 11.3 1.6 17.2 7.6 319 13 310 165 -3.7 0 -3.5 -4.2 11/04/2005 09:40:00 13.8 2.1 18.7 8.4 13.5 2.1 18.7 8.4 12.8 2 18.3 8.4 324 17 325 165 -3.6 0 -3.3 -3.7 11/04/2005 09:50:00 13.7 1.7 18.7 8.4 13.6 1.7 18.3 8 12.2 1.7 18.3 6.5 313 9 306 165 -3.7 0.1 -3.5 -3.9 11/04/2005 10:00:00 14.6 1.8 20.6 11.1 14.5 1.8 21 10.7 13.8 1.8 19.9 9.1 316 8 317 165 -3.7 0 -3.5 -3.9 11/04/2005 10:10:00 15 1.7 19.1 11.1 14.9 1.7 18.7 10.7 13.9 2 19.1 7.6 315 8 325 165 -3.7 0 -3.5 -3.9 11/04/2005 10:20:00 13.9 1.5 17.9 9.5 13.8 1.5 17.9 9.1 12.3 1.7 18.3 8 312 9 318 165 -3.7 0 -3.5 -3.9 11/04/2005 10:30:00 14.5 1.6 18.7 10.3 14.4 1.6 18.3 10.3 11.8 1.6 17.9 8.8 305 6 296 165 -3.8 0.1 -3.5 -3.9 11/04/2005 10:40:00 13.6 1.8 17.9 9.1 13.5 1.8 17.9 9.1 11.4 1.9 17.9 7.6 308 7 323 165 -3.7 0 -3.5 -3.7 11/04/2005 10:50:00 12.9 1.5 17.2 9.1 12.8 1.5 17.2 9.1 11.3 1.7 16.1 8 313 11 301 165 -3.5 0 -3.3 -3.5 11/04/2005 11:00:00 11.1 2.4 17.2 5.7 10.9 2.5 17.2 4.9 10.7 2.4 17.6 5.3 330 15 323 165 -3.3 0.2 -3 -3.7 11/04/2005 11:10:00 10.1 1.8 16.4 5.7 10 1.9 15.6 4.9 9.3 1.9 15.3 4.9 320 16 334 165 -3 0 -2.6 -3.3 11/04/2005 11:20:00 9 1.5 13.7 5.7 9 1.6 13.3 5.3 8.5 1.8 13.3 4.6 322 15 314 165 -2.6 0 -2.6 -2.8 11/04/2005 11:30:00 9.5 1.5 13.3 5.7 9.3 1.5 13.3 5.7 8.4 1.5 15.3 5.3 315 12 317 165 -2.5 0 -2.4 -2.8 11/04/2005 11:40:00 14.4 2.6 21 8.4 14.3 2.6 21 8.4 13.4 2.6 20.2 7.2 318 11 312 165 -2.7 0 -2.6 -2.8 11/04/2005 11:50:00 15.7 1.5 20.2 11.8 15.6 1.4 19.9 12.2 14.7 1.6 19.5 10.3 316 9 326 165 -3 0.1 -2.8 -3.3 11/04/2005 12:00:00 14.8 2.4 19.5 8.8 14.6 2.3 19.5 9.5 13.7 2.4 19.1 8.4 317 10 314 165 -3 0 -2.8 -3.3 11/04/2005 12:10:00 13.9 2 19.9 7.6 13.8 2 19.9 6.8 12.4 1.7 18.3 7.6 313 12 290 165 -3 0.1 -2.8 -3.3 11/04/2005 12:20:00 14.9 2.4 22.1 8.8 14.6 2.4 21.8 8 14.2 2.4 22.1 9.5 322 12 329 165 -2.8 0 -2.6 -3 11/04/2005 12:30:00 16.7 2.1 21.4 10.7 16.5 2.1 21.4 11.1 16.4 2.3 21.8 10.7 324 10 314 165 -2.8 0 -2.6 -3 11/04/2005 12:40:00 17 2.1 23.7 13 16.9 2.1 23.7 12.6 16.3 2.1 23.3 11.1 320 9 311 165 -2.9 0 -2.6 -3 11/04/2005 12:50:00 16 1.9 21.8 10.7 15.9 1.9 21.8 10.3 14.9 2.3 21 8.8 316 11 323 165 -2.8 0 -2.6 -2.8 11/04/2005 13:00:00 13.7 1.7 18.3 9.1 13.6 1.7 17.9 9.1 12.6 1.9 18.7 7.6 317 11 321 165 -2.7 0.1 -2.6 -3 11/04/2005 13:10:00 13.3 1.7 17.6 7.6 13.1 1.7 16.8 7.6 11.8 1.6 15.6 7.2 313 12 305 165 -2.6 0 -2.6 -2.8 11/04/2005 13:20:00 12.3 1.7 17.6 7.6 12.1 1.6 16.8 8 11.7 1.5 16.1 8.4 326 17 350 165 -2.5 0 -2.6 -2.8 11/04/2005 13:30:00 13 1.5 17.2 8.8 13 1.5 17.2 8.8 12 1.5 15.6 7.6 316 10 310 165 -2.6 0 -2.6 -2.8 11/04/2005 13:40:00 14.2 1.3 17.6 10.3 14.1 1.3 17.9 9.9 12.8 1.6 16.8 8.4 312 10 298 165 -2.8 0 -2.6 -3 11/04/2005 13:50:00 16.4 1.7 21 12.6 16.3 1.7 21 13 14.7 2 19.9 9.1 313 11 313 165 -2.9 0 -2.8 -3 11/04/2005 14:00:00 18.5 2 22.9 13.3 18.4 2 22.9 12.6 17 1.7 22.1 13 313 9 308 165 -2.9 0.2 -2.4 -3 11/04/2005 14:10:00 17.3 1.8 21.8 12.2 17.1 1.8 22.1 11.8 16.4 2 21.4 11.1 316 9 311 165 -2.9 0 -2.8 -3.3 11/04/2005 14:20:00 16.9 1.8 21.4 11.5 16.7 1.8 21.8 11.8 16 2 21.8 9.9 317 8 316 165 -2.9 0 -2.6 -3.3 11/04/2005 14:30:00 16.9 1.7 21 10.7 16.8 1.8 21 10.7 15.6 1.8 21.8 10.3 314 9 310 165 -2.9 0 -2.6 -3 11/04/2005 14:40:00 17.1 1.7 22.1 12.6 17 1.7 21.4 12.6 15.3 1.8 20.6 10.7 311 8 304 165 -3 0 -2.8 -3 11/04/2005 14:50:00 15.8 1.5 20.2 12.2 15.6 1.5 20.2 12.2 14.4 1.7 19.5 9.9 313 10 322 165 -2.9 0 -2.8 -3.3 11/04/2005 15:00:00 17.5 1.5 22.1 13 17.4 1.5 21.8 13 15.8 1.7 21.4 10.7 311 8 296 165 -3 0 -2.8 -3.3 11/04/2005 15:10:00 18.2 1.9 23.7 12.2 18.1 1.8 22.9 11.8 16.5 1.6 21.8 11.8 311 8 292 165 -3.1 0 -2.8 -3.5 11/04/2005 15:20:00 20 2.5 26 12.6 19.9 2.5 26 13 18.8 2.4 26 11.8 315 9 304 165 -3.2 0 -3 -3.3 11/04/2005 15:30:00 20.5 2 26 14.5 20.4 1.9 25.6 14.5 18.6 2.1 24.4 13 310 6 304 165 -3.3 0 -3.3 -3.5 11/04/2005 15:40:00 21.6 1.9 27.1 16.4 21.5 1.9 27.1 16.1 20.3 2.1 26 15.3 313 7 303 165 -3.4 0 -3.3 -3.5 11/04/2005 15:50:00 21.8 1.5 25.6 16.8 21.7 1.6 25.2 16.1 20.5 1.7 24.8 16.1 312 5 303 165 -3.5 0 -3.3 -3.5 11/04/2005 16:00:00 20.1 1.7 23.7 15.3 19.9 1.7 23.7 14.9 19.3 1.7 22.9 14.1 318 8 320 165 -3.5 0 -3.5 -3.7 11/04/2005 16:10:00 18.1 2.1 25.2 13.3 18 2.1 25.6 13 17.2 2.2 25.6 10.3 317 8 315 165 -3.6 0 -3.5 -3.7 11/04/2005 16:20:00 20.2 2 24.8 14.1 20 2.1 24.4 14.1 19.5 2.2 24 13 317 7 313 165 -3.7 0 -3.5 -3.9 11/04/2005 16:30:00 21.2 1.8 25.6 16.4 21.1 1.8 25.2 16.4 19.9 2 23.7 15.3 313 6 307 165 -3.9 0 -3.7 -3.9 11/04/2005 16:40:00 22.6 2.1 27.1 16.1 22.5 2.1 26.8 17.2 21.6 2.2 27.5 16.1 314 6 302 165 -3.9 0 -3.9 -4.2 11/04/2005 16:50:00 22.6 2 28.3 16.8 22.5 2.1 27.9 16.4 21.8 2.2 26.8 15.6 317 8 315 165 -4.2 0.1 -3.9 -4.2 11/04/2005 17:00:00 21.1 2 26.8 15.6 21 2 26.3 15.6 20.4 1.9 24.4 15.3 316 7 299 165 -4.2 0 -3.9 -4.4 11/04/2005 17:10:00 21.5 1.9 26 16.1 21.4 1.9 25.6 16.4 20.9 2.1 26.8 15.6 318 7 331 165 -4.2 0 -3.9 -4.4 11/04/2005 17:20:00 21.6 1.8 25.2 16.1 21.5 1.9 25.6 15.6 20.8 2.1 25.6 16.4 316 8 319 165 -4.3 0 -4.2 -4.4 11/04/2005 17:30:00 20.9 1.9 25.6 15.6 20.8 1.9 26 16.1 20.3 1.9 26 15.3 318 8 318 165 -4.3 0 -4.2 -4.4 11/04/2005 17:40:00 20.1 2 26.3 14.9 20 2 26 14.9 19.1 2 25.6 13 314 7 310 165 -4.3 0 -4.2 -4.4 11/04/2005 17:50:00 18.7 1.6 22.1 14.1 18.6 1.6 21.8 14.1 17.3 1.9 22.1 10.7 312 7 312 165 -4.3 0 -4.2 -4.4 11/04/2005 18:00:00 16.2 1.8 21 11.5 16.1 1.9 21 11.5 15.5 1.6 19.9 10.3 315 7 305 165 -4.3 0 -4.2 -4.6 11/04/2005 18:10:00 15.7 2.2 20.6 8.8 15.5 2.2 20.6 9.1 14.3 2.2 19.9 8.4 314 9 309 165 -4.2 0 -4.2 -4.6 11/04/2005 18:20:00 16.3 1.5 21.4 12.2 16.2 1.5 21 11.8 14.8 1.7 19.1 9.9 312 6 310 165 -4.3 0 -4.2 -4.4 11/04/2005 18:30:00 17.1 1.7 23.3 12.6 17 1.7 22.9 12.6 15.7 2 21.4 10.3 313 8 319 165 -4.3 0 -3.9 -4.6 11/04/2005 18:40:00 17 1.7 21.8 11.8 16.8 1.7 21.4 11.5 16.3 2 21.4 11.1 317 7 322 165 -4.2 0 -3.9 -4.4 11/04/2005 18:50:00 17.8 1.7 21.8 13 17.7 1.7 21.8 13.3 16.8 1.9 21.4 12.2 314 7 302 165 -4.1 0 -3.9 -4.4 11/04/2005 19:00:00 19.2 1.6 23.3 14.5 19.1 1.6 22.9 14.5 17.8 1.6 21.8 13.7 310 6 311 165 -4 0 -3.9 -4.4 11/04/2005 19:10:00 19.6 1.8 24.8 13.3 19.5 1.7 24.4 13.3 17.6 2.2 22.6 11.5 309 7 301 165 -4.2 0 -3.9 -4.4 11/04/2005 19:20:00 16.9 1.9 22.6 11.5 16.8 1.8 22.6 11.5 14.9 1.7 19.9 10.7 309 8 298 165 -4.1 0 -3.9 -4.4 11/04/2005 19:30:00 17.6 1.5 22.1 13.3 17.5 1.5 21.8 13 14.9 1.7 19.9 9.1 308 6 307 165 -4.2 0 -3.9 -4.4 11/04/2005 19:40:00 17.8 1.4 22.1 14.5 17.7 1.4 22.1 14.5 16.1 1.7 20.6 11.8 312 7 302 165 -4.2 0 -3.9 -4.4 11/04/2005 19:50:00 18.4 1.4 21.4 13.7 18.3 1.4 21.4 13.7 17.5 1.5 21.4 12.6 314 6 310 165 -4.2 0 -3.9 -4.4 11/04/2005 20:00:00 19 1.8 24.8 14.9 18.9 1.9 24.8 14.5 18.4 1.9 24 13.7 316 6 305 165 -4.3 0 -4.2 -4.6 11/04/2005 20:10:00 17.8 1.5 21.8 13 17.7 1.5 21.4 13 17.3 1.6 22.1 13.3 320 6 325 165 -4.3 0 -3.9 -4.6 11/04/2005 20:20:00 17.7 1.7 23.7 12.6 17.6 1.7 23.3 13.3 17.1 1.9 23.7 11.8 320 10 321 165 -4 0 -3.9 -4.4 11/04/2005 20:30:00 16.5 2 22.9 11.1 16.5 2.1 22.9 10.7 15.5 2.2 21.8 9.5 322 11 338 165 -4.2 0 -3.9 -4.4 11/04/2005 20:40:00 14.9 2.4 22.1 9.9 14.7 2.4 22.1 9.9 14.1 2.3 22.1 9.9 326 14 318 165 -4.2 0 -3.9 -4.4 11/04/2005 20:50:00 16.1 1.7 19.9 11.5 16 1.7 20.2 10.3 15.6 1.9 21.4 10.3 321 9 321 165 -4 0 -3.9 -4.4 11/04/2005 21:00:00 15.7 1.7 20.6 10.3 15.7 1.7 20.6 11.1 15.1 2 20.6 9.5 319 9 327 165 -4.2 0 -3.9 -4.4 11/04/2005 21:10:00 15.1 1.5 19.1 11.1 15 1.5 19.1 11.1 15 1.5 19.5 11.1 328 11 317 165 -4 0.1 -3.7 -4.4 11/04/2005 21:20:00 16.1 2.1 22.6 10.7 16 2.2 22.1 10.7 16 2.3 22.6 9.9 328 9 325 165 -4.1 0 -3.9 -4.4 11/04/2005 21:30:00 14.7 1.1 17.6 11.5 14.6 1.1 17.6 11.5 14.5 1.2 17.6 11.1 324 8 311 165 -4.3 0 -4.2 -4.6 11/04/2005 21:40:00 16.4 1.7 21 11.5 16.2 1.7 21 9.9 16 1.7 19.9 11.1 327 10 320 165 -4.3 0 -4.2 -4.6 11/04/2005 21:50:00 16.4 2.2 22.1 11.8 16.4 2.3 22.1 11.5 15.9 2.3 22.6 11.5 322 11 312 165 -4.1 0.1 -3.9 -4.6 11/04/2005 22:00:00 13.6 2.3 19.9 8 13.4 2.4 20.6 8 12.8 2.4 20.6 7.6 327 15 347 165 -4 0 -3.9 -4.4 11/04/2005 22:10:00 11.7 1.3 17.2 6.1 11.6 1.3 16.8 7.2 10.8 1.4 15.6 6.8 321 12 315 165 -4.2 0 -3.9 -4.4 11/04/2005 22:20:00 11.5 1.7 16.1 7.2 10.6 1.9 16.1 6.1 11.1 1.6 15.6 7.2 341 17 347 165 -3.9 0 -3.7 -4.2 11/04/2005 22:30:00 12.3 2.2 18.7 7.6 10.9 2.2 17.6 5.3 11.4 2.4 18.7 5.7 345 17 348 165 -3.9 0 -3.7 -4.2 11/04/2005 22:40:00 11.1 2.7 18.7 6.5 10.6 2.7 18.7 6.1 10.7 2.8 17.9 6.1 335 15 345 165 -4 0 -3.9 -4.4 11/04/2005 22:50:00 11.7 2.7 19.5 6.5 11.6 2.7 19.5 4.6 11.5 2.7 18.3 6.1 333 12 347 165 -3.9 0 -3.7 -4.2 11/04/2005 23:00:00 10.1 2.3 17.6 5.7 9.5 2 16.1 4.9 9.8 2.4 16.8 4.9 335 15 3 165 -3.8 0 -3.5 -3.9 11/04/2005 23:10:00 9.5 1.7 15.3 5.3 9.4 1.7 15.6 5.7 8.7 1.7 13.7 3.8 320 19 293 165 -3.8 0 -3.5 -3.9 11/04/2005 23:20:00 9.7 1.4 13.3 6.8 9.6 1.4 13 6.5 7.8 1.3 11.5 4.9 300 8 300 165 -4 0.1 -3.5 -4.2 11/04/2005 23:30:00 8 1.3 11.5 3.8 8 1.3 11.5 4.2 6.7 1.1 9.5 3.8 308 10 302 165 -4.2 0 -3.9 -4.4 11/04/2005 23:40:00 9.3 1.2 12.6 6.8 9.2 1.3 13.3 6.5 8.2 1.2 12.2 4.9 310 7 314 165 -4.2 0 -3.9 -4.4 11/04/2005 23:50:00 9.6 1.1 12.2 6.8 9.2 1.4 12.6 5.3 9 1.2 12.2 6.1 332 17 312 165 -4.5 0.1 -4.4 -4.6 11/05/2005 00:00:00 8.6 2 14.1 4.6 8.5 2.1 14.1 3.8 8.4 2.2 14.5 4.2 332 11 341 165 -4.4 0.2 -4.2 -4.6 11/05/2005 00:10:00 5.5 1 8 2.3 5.4 1 8.4 2.3 4.7 1 8 1.9 316 22 8 165 -4.5 0.1 -4.4 -4.6 11/05/2005 00:20:00 3.9 1.5 8.4 1.5 3.9 1.5 8.4 1.5 3.7 1.5 7.6 1.1 299 30 301 165 -4.4 0 -4.4 -4.8 11/05/2005 00:30:00 3.6 1.4 7.6 0.4 3.5 1.4 7.6 0.4 3.5 1.3 7.6 0.7 319 27 336 165 -4.3 0 -4.2 -4.6 11/05/2005 00:40:00 7 1.7 13.7 2.6 6.4 1.8 13.3 3 6.6 1.5 14.1 3.8 351 20 25 165 -4.3 0 -4.4 -4.6 11/05/2005 00:50:00 7.7 1.8 14.1 4.9 7.4 1.8 13.7 3.4 7.2 1.8 13 4.2 326 19 322 165 -4.5 0.1 -4.4 -4.8 11/05/2005 01:00:00 10.5 1 14.1 8 10.4 1 14.1 7.6 9.7 1.5 13.7 6.5 316 10 317 165 -4.3 0.1 -4.2 -4.6 11/05/2005 01:10:00 11.9 1.6 17.2 7.6 11.8 1.6 17.2 7.6 10.3 1.7 15.6 6.8 311 9 307 165 -4.2 0.1 -3.9 -4.4 11/05/2005 01:20:00 13.4 2 17.6 8.4 13.3 2 17.9 8.4 11.7 2.1 17.6 7.2 309 8 303 165 -4.1 0 -3.9 -4.4 11/05/2005 01:30:00 14.3 2.4 22.1 9.5 14.3 2.4 21.8 9.5 12.8 2.6 21.8 7.6 312 12 310 165 -3.9 0.1 -3.5 -4.2 11/05/2005 01:40:00 13 2.3 19.9 6.1 12.6 2.4 19.5 6.1 12.4 2.3 19.5 7.2 332 16 310 165 -3.7 0.1 -3.5 -3.9 11/05/2005 01:50:00 13.5 2.7 21.8 7.2 12.5 2.6 19.9 6.5 12.8 2.5 19.5 6.8 344 14 347 165 -3.8 0 -3.5 -3.9 11/05/2005 02:00:00 11.8 2.3 20.2 7.2 11.4 2.3 18.7 6.8 10.6 2.2 17.2 5.7 333 20 354 165 -4 0.1 -3.7 -4.2 11/05/2005 02:10:00 12.1 2.3 17.6 7.2 10.9 2.3 17.2 6.1 11.3 2.3 16.4 6.1 343 16 349 165 -4.1 0 -3.9 -4.4 11/05/2005 02:20:00 16.2 2.8 26.3 9.5 15.2 2.9 26 8 15.2 3.1 24.4 8.4 344 14 338 165 -4 0 -3.9 -4.4 11/05/2005 02:30:00 17.4 2.9 26 11.1 16.3 2.8 26 10.3 16.7 3.1 24.8 9.9 344 12 353 165 -3.9 0 -3.7 -4.2 11/05/2005 02:40:00 18.2 2.1 24 13 17 2.7 24.4 8.8 17.6 2.3 26 11.1 346 9 340 165 -4.1 0 -3.9 -4.2 11/05/2005 02:50:00 16.2 2.3 22.9 11.1 15.1 2.4 20.6 9.5 15.2 2.4 23.7 10.3 346 12 357 165 -4.2 0 -3.9 -4.4 11/05/2005 03:00:00 14.8 1.7 19.5 9.9 14.4 1.9 19.9 8.8 14.3 1.7 19.1 10.3 340 12 350 165 -4.3 0 -4.2 -4.4 11/05/2005 03:10:00 13.9 1.8 20.2 10.3 13.6 2 19.9 7.6 13.4 2 19.1 9.5 330 12 316 165 -4.3 0 -4.2 -4.6 11/05/2005 03:20:00 15 2.2 20.6 9.9 14.8 2.3 20.2 9.9 14.7 2.3 19.5 9.5 327 14 310 165 -4.2 0 -4.2 -4.6 11/05/2005 03:30:00 15 2.3 20.6 9.1 14.7 2.5 21 9.1 14.4 2.4 20.6 8.8 330 15 345 165 -4.3 0 -4.2 -4.4 11/05/2005 03:40:00 13.7 1.7 17.6 8.4 13.5 1.7 17.6 8 13.1 1.7 17.2 8.4 328 13 321 165 -4.5 0 -4.4 -4.6 11/05/2005 03:50:00 12.4 1.3 16.1 9.1 12.2 1.4 16.1 8.8 11.9 1.5 16.1 8 334 12 325 165 -4.6 0.1 -4.4 -4.6 11/05/2005 04:00:00 12.2 1.4 16.1 8.4 11.8 1.8 16.4 6.8 12 1.5 16.1 8.4 340 11 331 165 -4.7 0 -4.6 -4.8 11/05/2005 04:10:00 15.8 2.1 23.7 9.9 15.6 2.2 23.7 9.9 15.4 2 20.6 10.3 327 12 308 165 -4.6 0 -4.4 -5 11/05/2005 04:20:00 16.1 1.7 21.8 11.1 14.9 2.6 19.9 8 15.6 2 20.2 9.5 344 13 0 165 -4.5 0.2 -4.4 -4.6 11/05/2005 04:30:00 16.7 2.3 25.2 11.1 15.9 2.6 23.3 9.5 16.6 2.4 24 11.8 343 10 355 165 -4.7 0 -4.6 -4.8 11/05/2005 04:40:00 16 2.4 21 9.5 14.3 2.4 21.4 8 15.4 2.5 21.8 9.5 348 11 351 165 -4.7 0 -4.6 -4.6 11/05/2005 04:50:00 16.1 2.2 23.3 11.1 15 2.2 23.7 8.8 15.9 2.3 22.9 11.1 347 9 348 165 -4.7 0.1 -4.4 -4.8 11/05/2005 05:00:00 19.5 1.8 24.8 14.5 18.6 3.1 24 11.1 19.2 2.1 24 13.3 346 7 355 165 -4.7 0 -4.6 -4.8 11/05/2005 05:10:00 19.7 2.6 28.7 11.5 18.9 3.2 30.2 9.5 19.4 2.6 27.5 9.9 343 11 348 165 -4.7 0 -4.4 -4.8 11/05/2005 05:20:00 17.9 3.3 26 9.5 17.1 3.6 27.1 8 17.7 3.3 26 9.9 339 13 349 165 -4.7 0 -4.6 -4.8 11/05/2005 05:30:00 18.5 2.6 26 11.5 17.3 3.2 27.1 7.2 18 2.7 26 10.7 346 8 347 165 -4.7 0 -4.6 -5 11/05/2005 05:40:00 18.2 3.5 26 8.4 17.8 3.8 26 7.2 17.6 3.5 24.4 8.8 343 9 354 165 -4.7 0 -4.6 -4.6 11/05/2005 05:50:00 15.7 2.8 21.8 9.5 14.6 2.7 20.6 8 15.6 2.8 22.1 8.8 346 9 354 165 -4.6 0 -4.4 -4.8 11/05/2005 06:00:00 11.9 1.6 16.1 6.8 11.8 1.5 16.1 7.2 11.3 1.5 15.3 7.6 326 13 350 165 -4.8 0 -4.6 -5 11/05/2005 06:10:00 13.3 1.7 19.9 9.1 13.2 1.7 19.1 9.5 12.5 1.7 18.3 9.1 318 9 316 165 -4.8 0 -4.6 -5 11/05/2005 06:20:00 15.9 1.9 22.1 11.8 15.9 1.9 22.1 11.5 15.2 2.2 21.4 9.9 317 9 314 165 -4.7 0 -4.6 -5 11/05/2005 06:30:00 14.9 1.7 20.2 10.7 14.9 1.8 19.9 9.9 13.6 2.1 19.9 8 314 9 300 165 -4.7 0.1 -4.4 -4.8 11/05/2005 06:40:00 15.1 2 19.9 9.9 15 2.1 19.9 9.5 14.3 2.1 21.4 9.1 322 12 305 165 -4.7 0 -4.6 -4.8 11/05/2005 06:50:00 13.3 1.8 19.1 9.1 13.2 1.7 18.7 9.1 12.3 1.8 17.2 7.6 316 10 302 165 -4.8 0 -4.6 -5 11/05/2005 07:00:00 14 2.1 20.2 8 13.9 2.1 20.2 8 13.2 2.3 19.5 7.2 323 11 314 165 -4.8 0 -4.6 -5 11/05/2005 07:10:00 14.9 1.9 19.9 10.3 14.9 1.9 19.9 9.9 14 1.8 19.5 9.1 320 10 313 165 -4.7 0 -4.6 -4.8 11/05/2005 07:20:00 13.7 1.6 19.1 9.5 13.5 1.6 18.7 8.4 12.8 1.5 17.2 8.8 320 12 307 165 -4.7 0 -4.4 -5 11/05/2005 07:30:00 13.8 2 20.2 8.4 13.7 2.1 20.6 8.8 13 2.2 19.5 6.5 321 12 310 165 -4.8 0 -4.4 -5 11/05/2005 07:40:00 11.7 1.6 16.4 7.6 11.5 1.7 16.4 7.2 11.1 1.6 15.6 7.2 329 15 358 165 -4.7 0 -4.6 -4.8 11/05/2005 07:50:00 12.5 2.3 18.7 7.2 12.3 2.2 18.3 6.5 12 2.4 19.9 6.5 327 13 327 165 -4.6 0 -4.4 -4.8 11/05/2005 08:00:00 12.3 2.4 20.6 7.2 11.7 2 20.6 8 11.9 2.3 18.7 7.6 337 15 351 165 -4.7 0 -4.4 -4.8 11/05/2005 08:10:00 12.1 1.9 19.5 7.2 11.8 1.7 18.7 7.2 11.7 1.9 17.6 7.2 333 14 345 165 -4.7 0 -4.4 -4.8 11/05/2005 08:20:00 13.2 2.2 19.1 8.8 12.7 2 19.1 8.4 12.6 2.1 19.1 8.8 330 20 18 165 -4.5 0 -4.4 -4.8 11/05/2005 08:30:00 12.7 2.4 20.6 8.4 12.3 2.3 19.9 7.2 12.6 2.6 23.3 7.2 335 15 354 165 -4.7 0 -4.4 -4.6 11/05/2005 08:40:00 10.8 1.7 15.6 6.8 10.3 1.7 14.9 6.1 10.1 1.7 14.5 6.1 327 19 309 165 -4.5 0.1 -4.4 -4.6 11/05/2005 08:50:00 11 2.5 18.7 4.9 11 2.5 18.3 4.6 9.4 2.2 18.3 5.3 308 15 302 165 -4.2 0.1 -3.9 -4.6 11/05/2005 09:00:00 10.8 1.8 16.1 6.8 10.7 1.7 15.6 6.8 9 1.9 15.3 4.2 304 12 289 165 -3.9 0 -3.9 -4.2 11/05/2005 09:10:00 11.2 2.8 21 6.1 11 2.7 21 6.5 10.4 2.9 20.6 5.3 325 16 333 165 -3.6 0.1 -3.3 -4.2 11/05/2005 09:20:00 15.3 2.6 24 9.5 14.3 2.4 21 9.1 14.3 2.7 23.3 6.8 335 22 349 165 -3.5 0 -3.3 -3.7 11/05/2005 09:30:00 15.3 2.2 21 9.9 15 2.2 21 9.9 14.6 2.4 21.8 9.5 327 15 319 165 -3.5 0 -3.3 -3.9 11/05/2005 09:40:00 15.1 2 21.4 10.3 15.1 1.9 21 10.7 14.2 2 19.9 8.8 323 14 295 165 -3.4 0 -3.3 -3.5 11/05/2005 09:50:00 13.8 2.1 20.2 9.1 13.5 2.1 19.9 9.1 13 1.9 19.1 9.1 329 15 296 165 -3.3 0 -3.3 -3.5 11/05/2005 10:00:00 13.3 2.9 22.9 7.6 13.2 2.9 22.1 6.8 12.4 2.8 22.6 7.2 321 16 300 165 -3.2 0 -3 -3.5 11/05/2005 10:10:00 15.7 2.8 24 8.8 14.5 2.7 20.6 7.6 14.5 2.8 23.3 8.8 338 21 350 165 -3 0.1 -2.8 -3.3 11/05/2005 10:20:00 13.8 2.2 20.6 6.8 13.7 2.3 20.2 6.1 13.2 2.3 19.9 7.2 325 15 339 165 -3 0 -2.8 -3.3 11/05/2005 10:30:00 12 2.2 18.7 6.1 11.6 2.3 18.7 6.1 11.2 2.2 17.9 4.9 333 17 326 165 -3 0 -2.8 -3.3 11/05/2005 10:40:00 9.7 1.9 14.9 5.3 9.3 2 15.3 4.9 9.1 2 15.6 4.2 337 16 328 165 -2.8 0.1 -2.6 -3 11/05/2005 10:50:00 8.2 1.7 12.2 4.2 8 1.7 12.2 3.4 7.3 1.6 12.2 3.8 325 19 327 165 -2.5 0 -2.1 -2.6 11/05/2005 11:00:00 10.7 2.6 17.6 5.3 10.3 2.5 16.8 4.9 9.8 2.5 15.3 3.8 330 21 352 165 -2.3 0.2 -1.9 -2.6 11/05/2005 11:10:00 11.6 2.5 17.6 4.6 10.8 2.4 16.8 4.2 10.7 2.7 17.2 4.6 335 21 356 165 -2.5 0 -2.1 -2.8 11/05/2005 11:20:00 10.3 2.3 17.6 5.3 9.5 2.2 16.8 4.6 9.3 2.3 16.8 3.4 347 20 9 165 -2.1 0.2 -1.9 -2.6 11/05/2005 11:30:00 8.8 2.4 14.9 3.8 7.9 2.2 13.3 3 7.7 2.5 14.9 2.3 344 19 353 165 -1.8 0.2 -1.4 -2.1 11/05/2005 11:40:00 7.5 1.7 13 3.4 7 1.6 12.2 3 7.1 1.7 11.8 3 341 19 354 165 -1.7 0 -1.4 -1.9 11/05/2005 11:50:00 10.2 2.3 17.9 4.6 9.3 2.5 17.2 4.2 9.6 2.3 16.4 3.8 344 17 330 165 -1.7 0.1 -1.4 -1.9 11/05/2005 12:00:00 9.6 1.8 14.1 5.3 9.2 1.7 14.1 5.3 8.9 1.7 13.3 5.3 327 22 1 165 -1.7 0 -1.4 -1.9 11/05/2005 12:10:00 12.3 2.3 18.7 6.8 12.1 2.2 18.3 6.5 10.4 2.3 18.7 5.7 312 16 353 165 -1.8 0.1 -1.7 -2.1 11/05/2005 12:20:00 12 2 17.6 7.2 11.9 2 17.2 6.8 10.5 1.7 15.3 5.7 312 13 298 165 -1.8 0 -1.4 -2.1 11/05/2005 12:30:00 11.7 2.4 19.1 5.7 11.6 2.4 17.9 6.1 9.8 1.8 16.1 5.7 313 15 297 165 -1.7 0 -1.4 -1.9 11/05/2005 12:40:00 11.9 1.9 16.8 7.6 11.9 1.9 16.8 6.8 10.3 1.8 16.1 5.3 310 13 302 165 -1.5 0 -1.2 -1.9 11/05/2005 12:50:00 9.9 1.8 14.1 5.3 9.8 1.9 14.1 4.6 8.6 1.7 12.6 4.9 314 15 297 165 -1.4 0.1 -1 -1.9 11/05/2005 13:00:00 8 1.9 14.5 4.6 7.4 1.6 12.6 4.6 7.8 2.2 13.3 3.8 334 21 3 165 -1.2 0.1 -1 -1.4 11/05/2005 13:10:00 7 1.9 11.5 2.3 6.9 1.8 11.5 2.3 5.9 1.7 10.3 1.5 313 16 298 165 -1.1 0.2 -0.8 -1.4 11/05/2005 13:20:00 7.7 1.5 11.8 3.4 7.3 1.5 11.5 3.8 6.7 1.5 11.8 3.4 338 21 3 165 -0.6 0 -0.3 -1 11/05/2005 13:30:00 7.8 1.9 14.9 2.6 7.1 1.7 11.5 3 7.2 1.8 14.1 3.8 346 19 352 165 -0.5 0.1 -0.3 -0.8 11/05/2005 13:40:00 7.5 1.5 12.6 4.2 7.3 1.7 12.6 3.8 6.8 1.3 11.1 2.6 324 26 306 165 -0.5 0 -0.3 -0.5 11/05/2005 13:50:00 10.2 2.6 18.3 4.6 10.1 2.6 17.9 4.6 8.4 2.3 16.1 2.6 312 19 291 165 -0.7 0.1 -0.3 -0.8 11/05/2005 14:00:00 12.3 2.7 18.7 6.1 12.3 2.7 18.7 6.5 10.7 2.5 17.6 4.9 316 18 325 165 -0.9 0 -0.8 -1.2 11/05/2005 14:10:00 12.5 2.4 18.3 7.2 12.5 2.4 18.7 7.6 10.9 2.2 17.6 4.2 315 16 304 165 -1 0 -0.8 -1.2 11/05/2005 14:20:00 13.8 2.8 23.7 6.5 13.8 2.8 23.3 7.6 12.9 2.9 20.6 4.6 322 14 297 165 -0.8 0 -0.5 -1.2 11/05/2005 14:30:00 13.3 2.3 21.4 8.8 13.1 2.3 21.8 8 12.1 2.1 18.3 8 322 15 310 165 -0.8 0 -0.5 -1 11/05/2005 14:40:00 13.3 2.4 19.9 8 13.3 2.4 20.2 7.6 11.9 2.4 17.9 6.5 315 13 315 165 -0.6 0 -0.5 -0.8 11/05/2005 14:50:00 15.1 2.7 21 7.6 15 2.7 21 7.6 13.6 2.9 21.4 6.5 318 13 315 165 -0.5 0 -0.3 -0.8 11/05/2005 15:00:00 18.2 2.4 24.4 12.2 18.1 2.4 24 12.2 17.5 2.5 23.7 11.5 325 10 311 165 -0.7 0 -0.5 -0.8 11/05/2005 15:10:00 18 2.5 25.2 9.9 18 2.3 24.8 11.1 16.8 2.7 26.3 9.5 319 10 329 165 -0.4 0 -0.3 -0.8 11/05/2005 15:20:00 23 3.2 30.9 14.5 22.8 3.2 30.6 14.5 22.3 3.3 30.9 13.7 326 10 328 165 -0.5 0 -0.3 -0.8 11/05/2005 15:30:00 23.5 2.6 30.2 18.3 23.3 2.6 29.8 17.9 23 2.9 30.9 16.1 326 9 333 165 -0.5 0.1 -0.3 -0.8 11/05/2005 15:40:00 22.9 2.1 29.1 17.2 22.7 2.1 28.3 17.6 21.7 2.3 28.7 16.1 316 8 307 165 -0.8 0.2 -0.5 -1.2 11/05/2005 15:50:00 25.3 2.2 30.9 20.6 25.1 2.2 30.9 20.2 24.5 2.3 30.9 17.9 319 8 312 165 -1.1 0 -1 -1.2 11/05/2005 16:00:00 26 2.1 30.9 18.7 25.9 2.1 30.6 19.1 25.4 2.2 32.1 17.2 318 7 310 165 -1 0 -1 -1.2 11/05/2005 16:10:00 26.4 1.7 31.3 19.5 26.3 1.7 31.3 19.5 26.1 1.8 31.3 19.1 318 5 312 165 -1.2 0 -1 -1.4 11/05/2005 16:20:00 26.2 1.6 30.2 21.4 26 1.7 30.2 21 26 1.8 29.8 19.9 320 6 314 165 -1.3 0 -1.2 -1.4 11/05/2005 16:30:00 27.3 1.7 31.3 21 27.2 1.7 31.3 21.4 27.2 2 31.8 21.4 321 6 321 165 -1.4 0 -1.2 -1.4 11/05/2005 16:40:00 26.8 1.7 31.3 21.4 26.7 1.7 31.3 21 26.7 2 32.1 20.2 322 6 316 165 -1.6 0 -1.4 -1.7 11/05/2005 16:50:00 26.3 2.1 30.6 19.9 26.2 2.2 30.6 20.6 25.9 2.3 31.3 19.5 319 7 319 165 -1.8 0 -1.7 -1.9 11/05/2005 17:00:00 25.9 2 30.2 18.7 25.8 2.1 30.9 18.7 25.5 2.5 30.9 17.2 320 6 307 165 -1.9 0 -1.7 -2.1 11/05/2005 17:10:00 26 2 30.6 19.5 25.9 2 30.6 19.9 25.7 2.4 31.3 17.6 319 7 318 165 -1.8 0 -1.7 -2.1 11/05/2005 17:20:00 26 2.4 30.6 19.5 25.7 2.3 30.2 19.1 25 2.6 30.9 17.9 322 6 314 165 -2.1 0 -1.9 -2.1 11/05/2005 17:30:00 27.2 2.4 33.6 21.4 26.9 2.3 33.2 21.8 26.5 2.6 32.1 19.5 321 6 318 165 -2 0 -1.9 -2.1 11/05/2005 17:40:00 28.2 1.5 32.1 24 27.9 1.5 31.3 23.7 27.6 1.9 32.1 21.8 321 6 325 165 -2 0 -1.9 -2.1 11/05/2005 17:50:00 28.7 1.9 34 21.4 28.4 1.9 33.6 21.4 28.5 2.2 33.6 20.6 322 5 309 165 -2.1 0 -1.9 -2.1 11/05/2005 18:00:00 28.2 1.9 33.6 22.1 28 1.9 33.2 21.4 27.9 2.2 33.6 21.8 320 6 315 165 -2.1 0 -1.9 -2.1 11/05/2005 18:10:00 29.4 1.7 34.4 24 29.2 1.8 34.4 24.4 29.3 2.1 34.8 23.3 320 5 324 165 -2.1 0 -1.9 -2.4 11/05/2005 18:20:00 30.1 1.7 34 25.2 30 1.7 34 25.2 29.9 2.1 34.8 25.2 317 5 319 165 -2 0 -1.9 -2.1 11/05/2005 18:30:00 31.1 1.7 35.2 25.6 31.1 1.7 34.8 25.6 31.3 1.8 36.3 24.4 316 4 311 165 -1.9 0 -1.7 -2.1 11/05/2005 18:40:00 29.2 2.1 33.2 23.3 29.1 2.1 33.2 23.3 29 2.2 35.2 22.9 315 5 315 165 -1.8 0 -1.7 -1.9 11/05/2005 18:50:00 26.3 1.9 31.8 20.2 26.2 1.9 32.1 21.4 26.2 2.3 32.1 19.9 319 6 311 165 -1.8 0.1 -1.7 -2.1 11/05/2005 19:00:00 25.2 1.7 29.8 19.5 25.1 1.7 30.2 19.9 24.9 2 30.6 18.7 317 6 322 165 -2 0 -1.9 -2.1 11/05/2005 19:10:00 23.8 1.8 27.9 19.1 23.8 1.8 27.9 19.1 23.2 2 27.9 16.1 313 5 312 165 -2 0 -1.9 -2.1 11/05/2005 19:20:00 23.3 1.5 26.3 18.3 23.3 1.5 26 18.3 22.2 1.5 25.6 17.9 311 4 309 165 -1.9 0 -1.9 -2.1 11/05/2005 19:30:00 22 1.2 25.2 18.3 22 1.2 25.2 18.3 21.5 1.4 25.2 17.6 313 4 317 165 -2 0 -1.9 -2.1 11/05/2005 19:40:00 22.1 1.2 24.8 18.7 22.1 1.2 24.8 18.7 21.8 1.3 25.6 17.9 314 5 314 165 -2 0 -1.9 -2.1 11/05/2005 19:50:00 21.7 1.2 24.8 17.6 21.7 1.2 24.4 17.9 21 1.4 24.8 16.4 313 4 314 165 -2 0 -1.9 -2.1 11/05/2005 20:00:00 21.2 1.3 24.4 17.6 21.2 1.3 24 17.6 21 1.3 23.7 16.8 317 6 308 165 -2 0 -1.9 -2.1 11/05/2005 20:10:00 20.1 1.5 24 16.1 20.1 1.5 24 16.4 20 1.7 24.4 16.1 320 6 316 165 -2 0 -1.9 -2.1 11/05/2005 20:20:00 20.4 1.5 24 17.2 20.3 1.5 23.7 16.4 20 1.9 24.4 14.5 316 6 317 165 -1.8 0.1 -1.7 -2.1 11/05/2005 20:30:00 21.9 1.4 26.3 17.6 21.8 1.5 26.3 17.2 21.6 1.7 26.3 15.3 314 4 319 165 -1.8 0 -1.7 -1.9 11/05/2005 20:40:00 22.9 1.5 26.3 17.2 22.9 1.5 26.3 17.2 22.8 1.7 27.1 17.9 315 4 310 165 -1.7 0 -1.7 -1.9 11/05/2005 20:50:00 22 1.6 26 17.2 21.9 1.6 26 17.6 22 1.7 27.1 17.6 318 6 317 165 -1.7 0 -1.7 -2.1 11/05/2005 21:00:00 21.7 1.5 26.3 17.9 21.6 1.5 26.3 17.9 21.3 1.7 27.5 16.4 317 7 322 165 -1.7 0 -1.4 -1.9 11/05/2005 21:10:00 23.4 2.4 28.3 16.8 23.3 2.4 28.3 16.8 23.1 2.8 29.4 16.8 320 6 319 165 -1.6 0 -1.4 -1.9 11/05/2005 21:20:00 26.7 1.6 30.9 22.1 26.7 1.7 30.6 22.1 26.6 1.9 30.6 20.6 318 4 324 165 -1.3 0 -1.2 -1.7 11/05/2005 21:30:00 26.5 1.8 32.4 20.6 26.5 1.8 32.4 20.2 26.5 1.9 31.3 20.6 318 5 317 165 -1.2 0 -1.2 -1.4 11/05/2005 21:40:00 28.1 1.6 31.3 20.6 28.1 1.6 31.3 21 28.1 1.7 31.8 21.4 317 4 313 165 -1 0 -0.8 -1.4 11/05/2005 21:50:00 26.9 1.9 30.9 19.9 26.8 1.9 30.9 20.2 26.7 2.2 31.8 20.6 316 5 315 165 -0.9 0 -0.8 -1.2 11/05/2005 22:00:00 27.1 1.7 32.1 21.8 27 1.7 31.3 21.4 26.7 1.8 31.8 21 315 5 320 165 -0.7 0.1 -0.5 -1 11/05/2005 22:10:00 27.5 1.7 32.1 22.1 27.4 1.6 31.8 22.6 27.3 1.7 31.3 22.1 315 5 307 165 -0.5 0 -0.5 -0.8 11/05/2005 22:20:00 26.9 2 31.8 20.2 26.8 2.1 31.8 20.2 26.4 2.3 30.9 19.5 317 6 313 165 -0.1 0.3 0.7 -0.8 11/05/2005 22:30:00 27.2 1.7 33.2 23.3 27 1.7 32.4 23.3 26.6 1.9 33.2 21.4 318 5 316 165 0.2 0.1 0.7 -0.3 11/05/2005 22:40:00 26.4 1.6 32.1 19.9 26.2 1.6 32.1 20.2 26.1 1.9 30.9 19.1 319 5 323 165 -0.1 0 0.2 -0.3 11/05/2005 22:50:00 26 2.1 31.3 20.2 25.9 2.2 30.9 20.2 25.7 2.4 31.8 17.9 320 5 321 165 0 0 0.2 -0.5 11/05/2005 23:00:00 26.1 1.9 30.9 21 25.9 1.9 30.6 21 25.6 2.1 30.6 18.7 320 7 307 165 0.4 0 0.7 0.2 11/05/2005 23:10:00 25.2 2.4 31.8 16.4 25 2.4 31.8 16.4 24.6 2.5 31.3 16.8 320 8 313 165 0.8 0.1 0.9 0.7 11/05/2005 23:20:00 23.7 2 29.4 17.6 23.6 2 29.8 17.2 23.1 2 29.1 17.2 318 7 316 165 0.5 0 0.7 0.2 11/05/2005 23:30:00 22.2 2.6 28.3 14.5 22.1 2.6 28.3 14.9 21.4 2.8 27.5 13 317 7 312 165 0.4 0.1 0.7 0.2 11/05/2005 23:40:00 21.1 1.8 25.2 16.1 21 1.8 25.2 15.6 19.7 2.1 24.8 14.1 313 7 311 165 0 0 0.2 -0.3 11/05/2005 23:50:00 20.5 1.5 23.7 16.4 20.4 1.5 23.7 16.4 19.4 1.7 23.7 13.7 314 6 311 165 -0.3 0 -0.1 -0.5 11/06/2005 00:00:00 19.3 2.2 25.2 13 19.2 2.2 25.2 12.6 18.4 2.5 25.2 12.6 313 6 313 165 -0.3 0 -0.1 -0.3 11/06/2005 00:10:00 17.2 1.3 20.6 13.7 17.1 1.3 20.6 13.3 16.3 1.5 19.5 11.1 316 6 314 165 -0.3 0 -0.1 -0.5 11/06/2005 00:20:00 15.9 1.3 19.9 12.2 15.8 1.3 19.5 12.2 15 1.5 19.5 11.1 315 6 317 165 -0.3 0 -0.3 -0.5 11/06/2005 00:30:00 16.9 1 19.9 14.1 16.8 1.1 19.9 13.7 15.6 1.5 19.1 11.5 313 5 312 165 -0.3 0 -0.1 -0.5 11/06/2005 00:40:00 13.9 1.6 18.3 10.3 13.8 1.6 17.9 10.3 12.8 1.7 17.2 8.4 312 5 316 165 -0.3 0 -0.1 -0.3 11/06/2005 00:50:00 11.3 1.2 14.1 7.6 11.3 1.2 14.5 8 10.4 1.5 13.7 6.5 313 6 307 165 -0.3 0 -0.1 -0.5 11/06/2005 01:00:00 12.5 1.5 16.4 9.1 12.4 1.5 16.4 9.1 11.1 1.3 14.9 6.5 310 6 307 165 -0.3 0 -0.1 -0.8 11/06/2005 01:10:00 13.6 1.1 16.4 10.3 13.5 1.1 16.1 10.3 12.1 1.4 15.6 8 310 5 309 165 0.1 0.2 0.2 -0.5 11/06/2005 01:20:00 15.3 1.2 17.9 12.2 15.2 1.2 17.6 11.5 12.9 1.4 16.8 9.1 309 5 304 165 0.2 0 0.7 -0.1 11/06/2005 01:30:00 14.1 1.2 17.2 10.3 14 1.2 17.2 10.7 12.1 1.3 15.6 8 309 4 313 165 0.5 0 0.7 0.2 11/06/2005 01:40:00 11.6 1.4 15.6 8.8 11.6 1.4 16.1 8.8 9.9 1.2 13 6.5 308 5 308 165 0.6 0 0.7 0.7 11/06/2005 01:50:00 9.6 1 12.2 6.5 9.5 1 11.8 6.5 8.2 1.1 11.5 5.7 307 6 312 165 0.6 0 0.7 0.7 11/06/2005 02:00:00 8 1 10.3 5.7 8 1 9.9 5.3 7 0.9 9.1 3.8 310 8 307 165 0.4 0.1 0.7 0.2 11/06/2005 02:10:00 6.6 1.1 9.5 3.4 6.6 1.1 9.5 3.8 5.2 1.1 8 2.3 301 8 292 165 0.5 0 0.7 0.2 11/06/2005 02:20:00 4.6 1.1 9.5 2.3 4.9 1.1 9.5 2.6 4.2 1 8.8 1.9 283 15 276 165 0.7 0.1 0.9 0.2 11/06/2005 02:30:00 6.7 1.5 10.7 3.8 6.7 1.5 10.3 3.4 5.7 1.7 10.3 2.6 294 12 279 165 0.8 0 0.9 0.7 11/06/2005 02:40:00 6.7 1 9.1 4.2 6.9 1.1 9.5 3.8 6.1 1.2 8.8 3.4 284 10 277 165 0.8 0.2 1.4 0.7 11/06/2005 02:50:00 7.7 1 9.9 4.9 7.8 0.9 10.3 5.7 7.2 1 9.9 4.6 282 7 286 165 1.3 0.1 1.6 0.9 11/06/2005 03:00:00 6 1.1 8.8 3 6.2 1 8.8 4.2 6 1.1 9.5 3.8 275 9 283 165 1.7 0 1.8 1.4 11/06/2005 03:10:00 2.8 1.1 5.7 0.4 3.3 1.4 6.5 0.4 3 1.2 6.8 0.4 241 26 243 165 1.3 0.3 1.8 0.9 11/06/2005 03:20:00 4 0.7 5.7 2.6 4.2 0.7 6.1 2.6 3.9 0.6 6.1 2.6 253 21 271 165 1.3 0.2 1.8 0.9 11/06/2005 03:30:00 3.1 0.7 4.6 1.5 3 0.8 4.6 1.5 3.1 0.8 4.6 1.5 208 19 204 165 1.3 0.1 1.4 0.9 11/06/2005 03:40:00 4 0.9 7.2 1.9 4.4 1 7.6 1.9 4.2 1 8 1.9 252 14 276 165 2.1 0.3 2.6 1.4 11/06/2005 03:50:00 5.6 1.4 8.4 1.9 6.2 1.3 8.8 2.6 5.8 1.3 9.1 0.7 268 15 276 165 2.6 0 2.8 2.3 11/06/2005 04:00:00 8.9 2.9 16.8 4.2 9.1 2.8 16.8 4.6 8.2 2.6 16.4 2.6 284 12 300 165 2.9 0 3.3 2.6 11/06/2005 04:10:00 10.4 1.9 16.8 6.5 10.5 1.9 16.4 6.8 9.6 2.1 15.3 4.9 285 11 284 165 3.2 0 3.3 2.8 11/06/2005 04:20:00 11.3 3.1 18.7 3.8 11.5 3.1 19.1 4.6 9.9 2.9 19.5 4.9 287 15 282 165 3.4 0.2 3.5 2.8 11/06/2005 04:30:00 12 2.2 16.4 6.8 12 2.2 17.2 6.5 10.6 2.3 17.2 5.7 290 9 279 165 3.6 0 3.8 3.3 11/06/2005 04:40:00 12.1 2.7 18.7 6.1 12.2 2.7 18.7 6.1 11 2.9 19.1 6.1 287 9 278 165 3.7 0 3.8 3.5 11/06/2005 04:50:00 10.7 2.1 16.1 6.5 10.6 2.1 16.4 6.1 9.4 2.4 16.4 5.3 295 12 277 165 3.9 0 4 3.5 11/06/2005 05:00:00 11.8 2.2 16.8 6.8 11.7 2.2 16.8 6.1 9.9 2.2 15.3 5.3 302 12 313 165 3.8 0 3.8 3.5 11/06/2005 05:10:00 11.6 2.3 17.2 6.5 11.4 2.3 17.6 6.5 9.9 2.3 17.6 5.7 308 11 326 165 3.7 0 4.3 3.5 11/06/2005 05:20:00 14.8 2.6 23.3 8.4 14.9 2.6 22.9 8 13 2.9 23.3 4.9 289 9 283 165 4.1 0 4.5 3.8 11/06/2005 05:30:00 16.4 2.7 22.9 7.2 16.4 2.7 22.9 9.1 13.8 2.9 22.1 8 291 9 282 165 4.2 0 4.5 4 11/06/2005 05:40:00 15.7 2.2 20.6 8.8 15.6 2.2 20.2 9.1 12.9 2.1 18.7 8.8 293 8 293 165 4.3 0.1 4.5 4.3 11/06/2005 05:50:00 15.5 2.4 22.1 9.9 15.4 2.4 22.6 9.9 13.1 2.4 18.7 7.2 293 9 293 165 4.4 0 4.8 4.3 11/06/2005 06:00:00 17.3 3.6 25.6 10.3 17.2 3.8 25.6 9.5 15.1 3.6 26.3 8.4 297 12 299 165 4.6 0 5 4.5 11/06/2005 06:10:00 19.9 2.4 26.8 14.9 19.9 2.5 27.5 14.5 17.1 2.8 27.1 11.1 292 9 285 165 4.9 0 5 4.8 11/06/2005 06:20:00 16.5 2.5 24.4 10.3 16.5 2.6 24.4 10.3 14 2.9 22.1 8.4 295 10 307 165 5 0 5.2 4.8 11/06/2005 06:30:00 16.2 1.7 19.9 10.7 16.2 1.7 20.2 10.7 13.6 2.1 19.1 8.8 294 9 292 165 5 0 5.2 4.8 11/06/2005 06:40:00 17.3 2.7 23.3 11.5 17.3 2.7 23.3 11.5 14 3.3 22.9 7.6 293 6 284 165 4.9 0 5 4.8 11/06/2005 06:50:00 16.2 1.9 21.8 12.2 16.1 1.9 21.8 12.2 13.2 2.4 22.6 8 300 9 292 165 4.9 0 5 4.8 11/06/2005 07:00:00 18.5 2.7 24.8 11.1 18.3 2.7 24.4 11.1 16.2 3.2 25.6 8.4 305 9 305 165 4.9 0 5.2 4.8 11/06/2005 07:10:00 18.2 2.1 23.3 12.2 18.2 2.1 23.7 12.2 16.2 2.4 22.1 9.1 307 7 309 165 4.9 0.1 5.2 4.5 11/06/2005 07:20:00 16.4 2.3 23.7 12.2 16.3 2.4 23.3 11.8 14 2.6 21.4 8.8 302 9 296 165 4.5 0 4.8 4.5 11/06/2005 07:30:00 18.7 2.8 27.1 13 18.6 2.8 26.8 12.2 16.2 2.7 26 9.9 299 11 290 165 4.6 0 4.8 4.5 11/06/2005 07:40:00 19.1 2.3 25.2 13 19 2.4 25.2 12.6 16.1 2.6 24.4 10.3 300 9 290 165 4.8 0 5 4.5 11/06/2005 07:50:00 18.6 2.2 23.7 13.3 18.5 2.3 24 12.6 15.8 2.6 23.7 9.9 301 11 301 165 5.1 0.2 5.5 4.5 11/06/2005 08:00:00 21.3 3.2 28.3 13 21.2 3.2 28.7 13.3 19.3 3.6 28.3 12.2 306 10 300 165 5.6 0 5.7 5.2 11/06/2005 08:10:00 24.4 2.8 31.3 17.6 24.2 2.8 31.3 17.9 21.6 3.3 29.8 13.3 305 9 310 165 5.8 0 6 5.5 11/06/2005 08:20:00 22.4 2.7 30.9 14.1 22.3 2.7 30.9 14.5 20 3.5 29.8 10.3 306 8 302 165 5.9 0 6 5.7 11/06/2005 08:30:00 21.6 2.7 29.8 14.1 21.5 2.7 29.8 14.5 18.9 3.6 28.7 10.7 303 10 298 165 6.1 0 6.2 5.7 11/06/2005 08:40:00 17.9 2.9 27.1 11.8 17.8 3.1 27.1 11.8 15.3 2.7 26 9.9 301 10 289 165 5.9 0.1 6.2 5.7 11/06/2005 08:50:00 17.9 2.7 26.3 10.3 18 2.8 26.8 9.9 16.6 3.5 24.4 8.8 295 13 290 165 5.7 0.3 6.2 5.2 11/06/2005 09:00:00 17.7 2.7 25.6 9.9 17.6 2.7 24.8 10.3 16 2.9 23.3 8.4 297 10 315 165 5.4 0.2 6 5 11/06/2005 09:10:00 18.3 3.2 26.3 11.5 18.2 3.2 26.8 11.8 16.3 3.5 24.8 9.1 299 11 294 165 5.8 0.1 6 5.7 11/06/2005 09:20:00 15.5 2.5 21.8 10.3 15.4 2.5 21.8 10.7 14 2.8 21.4 8.8 291 9 284 165 5.5 0.1 5.7 5.2 11/06/2005 09:30:00 15.3 1.8 19.5 9.9 15.3 1.8 19.5 9.5 13.6 2.5 19.5 8 292 8 298 165 5.3 0 5.7 5 11/06/2005 09:40:00 13 1.9 17.9 8 13 2 18.3 8.4 11.3 2.1 16.8 6.5 296 12 299 165 5.6 0 5.7 5.5 11/06/2005 09:50:00 14.9 2.4 21.8 8.8 14.9 2.4 22.1 8.8 13.1 2.8 21.4 6.8 298 13 282 165 5.9 0 6 5.5 11/06/2005 10:00:00 17.8 3.1 24.8 9.1 17.7 3.1 24 9.1 16.3 3.5 23.3 8.4 309 9 312 165 6.3 0.1 6.5 5.7 11/06/2005 10:10:00 17.3 2.6 23.3 11.1 17.2 2.6 23.3 11.5 15 2.9 22.9 8.8 307 9 308 165 6.4 0 6.5 6.2 11/06/2005 10:20:00 18.1 2.7 25.2 10.3 18 2.7 24.8 10.7 15.8 2.9 22.9 7.6 306 8 308 165 6.4 0 6.7 6.2 11/06/2005 10:30:00 17.6 3.1 25.2 10.7 17.5 3.1 24.8 10.7 15 3.2 24.8 8.4 300 12 288 165 6.5 0 6.7 6.2 11/06/2005 10:40:00 17.2 2.6 24.4 10.3 17.1 2.6 24.4 10.3 15 3.1 22.1 8.8 304 10 304 165 6.6 0 6.7 6.5 11/06/2005 10:50:00 17.1 2.7 23.7 11.5 17 2.7 23.7 11.1 14.8 3.1 23.3 8.4 301 12 298 165 6.6 0 6.7 6.2 11/06/2005 11:00:00 18.2 3.2 29.1 8.8 18 3.1 28.7 9.1 15.6 3.2 25.6 9.1 304 11 300 165 6.5 0 7 6.2 11/06/2005 11:10:00 19 3.1 26.8 11.5 18.9 3.1 27.1 11.5 16.5 3.5 25.6 9.5 304 11 304 165 6.5 0 6.7 6.2 11/06/2005 11:20:00 23.1 3.8 33.2 13 22.9 3.8 32.9 12.6 21 4.1 31.8 11.8 307 8 309 165 6.6 0 6.7 6.2 11/06/2005 11:30:00 21.5 3.5 29.4 14.5 21.4 3.5 29.8 14.5 19.5 4 30.6 11.1 307 8 309 165 6.5 0 6.7 6.2 11/06/2005 11:40:00 21.2 4 31.3 13.3 21.1 4 31.3 13.3 19.2 4.3 31.3 9.5 308 9 290 165 6.3 0 6.7 6.2 11/06/2005 11:50:00 18.6 3.2 27.5 12.2 18.5 3.2 27.9 12.2 16.2 3.5 28.7 8.8 301 12 280 165 6.2 0 6.2 6 11/06/2005 12:00:00 19.7 4.3 34.4 11.8 19.6 4.3 33.6 11.8 17.8 4.5 32.4 9.5 309 9 310 165 6.2 0.1 6.2 5.7 11/06/2005 12:10:00 24.6 3.3 35.9 16.1 24.5 3.3 35.2 16.8 21.6 4 30.6 12.6 307 8 304 165 6.2 0 6.2 5.7 11/06/2005 12:20:00 25.6 3.6 34.4 16.4 25.5 3.6 33.6 16.1 22 4 32.9 11.5 301 8 312 165 6.1 0 6.2 5.5 11/06/2005 12:30:00 24 3.1 32.1 15.6 23.8 3.1 31.8 16.1 21.6 3.2 31.8 13 309 9 305 165 5.9 0.1 6 5.2 11/06/2005 12:40:00 22.9 3.6 29.8 15.3 22.8 3.8 29.8 14.9 19.6 3.6 29.8 11.1 304 8 310 165 5.7 0 6.2 5.2 11/06/2005 12:50:00 20.8 3.1 29.4 14.5 20.6 3.1 29.4 14.1 18.8 2.9 24.8 12.2 310 10 291 165 5.5 0 5.7 5.2 11/06/2005 13:00:00 18.4 2.5 25.6 12.2 18.3 2.5 25.6 12.2 16.1 2.6 24.4 11.1 306 11 310 165 5.4 0 5.5 5.2 11/06/2005 13:10:00 19.3 3.2 26.8 11.1 19.2 3.2 26.8 10.3 17.8 3.3 26.3 10.3 313 9 298 165 5.2 0 5.5 5 11/06/2005 13:20:00 21.6 3.1 28.3 13.3 21.4 3.1 28.3 13.3 19.8 3.3 27.9 11.5 310 7 291 165 4.9 0 5.2 4.8 11/06/2005 13:30:00 22.8 2.9 30.2 14.5 22.7 3.1 29.8 14.1 20.5 3.3 30.6 13 308 7 306 165 4.4 0.1 4.8 4.3 11/06/2005 13:40:00 21.3 2.6 29.8 16.1 21.2 2.5 29.4 16.1 20 2.5 27.9 11.5 310 8 303 165 3.6 0.4 4.3 2.8 11/06/2005 13:50:00 16.5 2.1 21.8 11.1 16.4 2.1 21.8 10.7 16.1 2.1 21 10.3 319 8 310 165 2.1 0.3 2.8 1.6 11/06/2005 14:00:00 18.5 2 24 11.5 18.4 2 23.3 11.1 17.9 2.2 22.6 10.7 318 9 319 165 1.5 0.1 1.8 1.4 11/06/2005 14:10:00 17.6 2.3 24.8 12.2 17.6 2.3 24.8 11.8 17.5 2.4 24.4 11.1 318 8 313 165 1.4 0 1.4 1.1 11/06/2005 14:20:00 14.9 2.2 21.4 10.7 14.6 2.3 21 8.8 14.2 2.1 19.9 9.9 329 13 326 165 1.3 0 1.4 1.1 11/06/2005 14:30:00 15.3 2.3 25.6 10.3 15.1 2.5 25.6 9.1 14.7 2.2 22.9 10.7 331 16 300 165 1.1 0 1.4 0.9 11/06/2005 14:40:00 16.7 2.9 24 10.3 16.1 2.8 23.7 9.5 16 2.8 23.7 10.3 338 14 351 165 0.7 0 1.1 0.4 11/06/2005 14:50:00 17.3 2.5 24.4 11.1 16.7 2.8 25.2 9.5 16.9 2.7 25.2 10.7 339 15 340 165 0.2 0.1 0.7 0.2 11/06/2005 15:00:00 18.7 2.8 24.8 11.1 18.6 2.9 25.2 11.1 18.2 2.8 24.8 11.1 333 11 344 165 0 0 0.4 -0.1 11/06/2005 15:10:00 16.6 1.8 22.9 12.6 16.3 2 22.9 10.3 15.9 1.9 22.1 11.8 325 14 325 165 -0.2 0 -0.1 -0.3 11/06/2005 15:20:00 17.5 1.8 22.1 11.1 17.3 1.9 22.1 10.7 16.8 1.7 21.4 11.8 326 12 326 165 -0.3 0 -0.1 -0.5 11/06/2005 15:30:00 17.7 2.3 24.4 11.5 17.6 2.2 24.4 11.8 16.9 2.6 25.2 11.1 318 10 313 165 -0.4 0 -0.3 -0.5 11/06/2005 15:40:00 17.4 2.6 27.9 11.1 17.3 2.6 27.9 11.1 16.2 2.4 23.3 9.9 317 12 305 165 -0.5 0 -0.3 -0.8 11/06/2005 15:50:00 14.9 2 22.1 10.7 14.9 2 22.9 11.1 14.1 2.1 21.4 9.9 318 11 302 165 -0.7 0 -0.5 -0.8 11/06/2005 16:00:00 12.7 1.8 18.7 9.5 12.6 1.9 19.5 9.1 12.1 1.8 17.6 7.6 326 12 317 165 -0.9 0 -0.8 -1 11/06/2005 16:10:00 12.5 1.5 16.4 8.4 12.3 1.7 16.4 4.9 12 1.5 16.1 8.4 330 13 322 165 -1.1 0 -0.5 -1.2 11/06/2005 16:20:00 14.3 2.1 22.6 8.4 14.1 2.4 23.3 7.6 13.7 2.2 19.9 7.2 329 15 293 165 -1.4 0.1 -1.2 -1.4 11/06/2005 16:30:00 16.8 2.4 22.1 10.7 16.8 2.4 22.6 10.7 16.7 2.6 22.6 11.1 322 10 316 165 -1.4 0 -1.2 -1.7 11/06/2005 16:40:00 16 1.9 20.6 11.5 15.5 2 20.6 9.1 15.4 2 21.4 10.3 330 15 308 165 -1.6 0 -1.4 -1.9 11/06/2005 16:50:00 17.8 2.4 23.7 10.3 17.2 2.7 23.3 10.3 17 2.5 23.7 9.9 329 18 2 165 -1.7 0 -1.7 -1.9 11/06/2005 17:00:00 16.9 1.5 20.2 11.8 16.8 1.5 20.2 13 16.5 1.6 19.9 12.2 323 10 325 165 -1.9 0.1 -1.7 -2.1 11/06/2005 17:10:00 15.3 1.5 20.2 10.7 15.2 1.5 20.2 10.7 15.1 1.5 18.7 10.3 323 9 313 165 -2 0 -1.9 -2.1 11/06/2005 17:20:00 16 2.4 24.8 10.3 15.9 2.4 24.8 10.7 15.4 2.6 24.4 10.3 322 9 310 165 -2.2 0 -2.1 -2.4 11/06/2005 17:30:00 19.2 1.7 23.3 14.1 19.1 1.7 23.3 13.3 18.8 1.7 23.3 14.1 320 6 319 165 -2.2 0 -1.9 -2.4 11/06/2005 17:40:00 21.9 2.1 26 15.3 21.8 2.1 25.6 14.5 21.6 2.3 25.6 13.7 319 6 316 165 -2.2 0 -2.1 -2.4 11/06/2005 17:50:00 21.3 2.3 27.1 14.5 21.1 2.2 26.8 15.3 21 2.4 27.1 14.5 326 6 326 165 -2.3 0 -2.1 -2.6 11/06/2005 18:00:00 21.8 2.1 26.8 16.8 21.6 2.2 26.8 16.4 21.7 2.1 26.8 15.3 324 7 339 165 -2.1 0 -1.9 -2.4 11/06/2005 18:10:00 22 2.1 27.5 17.2 21.9 2.1 26.8 17.2 21.8 2.3 27.5 15.3 322 6 323 165 -2 0 -1.9 -2.1 11/06/2005 18:20:00 21.4 1.8 26.3 15.3 21.2 1.8 26 14.9 21.1 2.1 27.5 14.5 319 7 315 165 -2.1 0 -1.9 -2.4 11/06/2005 18:30:00 22.5 1.7 26.8 18.7 22.5 1.7 26 18.3 21.5 1.5 25.2 16.8 313 6 300 165 -2.2 0 -2.1 -2.6 11/06/2005 18:40:00 20.4 1.9 24.8 15.6 20.2 1.9 24.8 15.6 19.9 1.9 25.6 14.5 320 8 315 165 -2.3 0 -2.1 -2.6 11/06/2005 18:50:00 20.9 1.5 25.2 15.6 20.8 1.5 24.8 16.1 20.1 1.7 23.7 15.3 315 7 313 165 -2.3 0 -2.1 -2.6 11/06/2005 19:00:00 20.7 1.7 26.3 15.6 20.5 1.7 26.3 15.3 20 2.2 26.8 14.5 317 8 325 165 -2.3 0 -2.1 -2.6 11/06/2005 19:10:00 22.3 2 29.1 17.2 22.1 2 27.5 17.6 21.8 2.5 27.1 14.1 319 7 319 165 -2.3 0 -2.1 -2.6 11/06/2005 19:20:00 19.8 2 26 15.3 19.7 2 25.6 14.9 18.9 2.1 24.4 13.3 315 8 305 165 -2.4 0 -2.1 -2.6 11/06/2005 19:30:00 20.5 1.8 24.8 15.6 20.2 1.7 24 14.9 20 2.1 24 14.1 323 6 333 165 -2.3 0 -2.1 -2.6 11/06/2005 19:40:00 19.6 1.6 23.7 15.3 19.5 1.6 23.7 15.3 19 1.9 23.3 13.3 319 6 311 165 -2.4 0 -2.1 -2.6 11/06/2005 19:50:00 13.9 1.6 18.3 9.5 13.8 1.6 17.9 9.5 13 1.7 17.9 8 318 9 318 165 -2.4 0.1 -2.1 -2.6 11/06/2005 20:00:00 10.8 1.7 15.3 7.2 10.7 1.7 14.9 6.1 10.1 1.8 15.6 6.1 320 10 316 165 -2.6 0 -2.6 -2.8 11/06/2005 20:10:00 10.3 1.6 16.1 6.1 10.2 1.6 15.6 6.5 9 1.5 13.7 5.3 314 11 325 165 -2.5 0 -2.4 -2.8 11/06/2005 20:20:00 9.4 1.2 12.6 6.5 9.2 1.2 12.2 6.5 8.6 1.3 11.5 5.3 311 6 310 165 -2.5 0 -2.4 -2.6 11/06/2005 20:30:00 8.1 1 11.5 5.7 8 1 11.1 5.3 6.8 1.3 10.3 3.8 300 11 310 165 -2.5 0 -2.6 -2.8 11/06/2005 20:40:00 9.8 1.2 13.3 6.1 9.7 1.2 13 6.5 8.8 1.2 11.5 5.3 311 10 313 165 -2.5 0 -2.4 -2.8 11/06/2005 20:50:00 10.2 1.3 14.1 6.8 10.1 1.3 14.1 6.8 9.3 1.3 12.6 6.5 312 7 304 165 -2.4 0 -2.1 -2.6 11/06/2005 21:00:00 11.4 1.2 14.1 8.4 11.3 1.2 14.1 8.4 10.6 1.3 13.7 6.5 313 6 319 165 -2.4 0 -2.1 -2.6 11/06/2005 21:10:00 11.2 1.2 14.5 8 11 1.2 14.1 8.4 10.1 1.4 14.1 6.5 313 8 299 165 -2.6 0 -2.4 -2.8 11/06/2005 21:20:00 10.9 1.3 14.5 8 10.8 1.3 14.5 7.6 10.3 1.5 14.5 6.8 317 7 310 165 -2.5 0 -2.6 -2.8 11/06/2005 21:30:00 12.9 1.2 16.4 9.1 12.7 1.2 16.4 9.1 11.3 1.2 15.6 8.4 310 7 302 165 -2.6 0 -2.4 -2.8 11/06/2005 21:40:00 12 1.2 15.6 9.1 11.9 1.3 16.1 8.4 10.3 1.3 13.3 6.1 309 7 302 165 -2.5 0 -2.4 -2.6 11/06/2005 21:50:00 10.7 1.7 15.3 7.6 10.6 1.7 15.3 7.6 8.4 1.2 13.7 5.3 302 7 305 165 -2.4 0 -2.1 -2.6 11/06/2005 22:00:00 9.1 1.1 11.8 6.8 9.1 1.1 11.5 6.5 7.4 1.2 10.7 5.3 304 7 301 165 -2.5 0 -2.4 -2.8 11/06/2005 22:10:00 8.5 1.1 11.8 6.5 8.4 1.1 11.5 6.1 7.1 1 10.3 4.6 306 7 297 165 -2.5 0 -2.4 -2.8 11/06/2005 22:20:00 10.9 1.5 14.5 7.6 10.9 1.5 14.5 7.6 8.7 1.6 13.7 5.3 295 7 287 165 -2.3 0 -2.1 -2.8 11/06/2005 22:30:00 11.1 1.9 15.6 6.8 11.1 2 15.6 6.5 9.1 1.8 15.3 4.9 299 8 300 165 -2.3 0 -2.1 -2.6 11/06/2005 22:40:00 11.6 1.7 15.3 7.2 11.5 1.7 15.3 7.2 9.2 1.7 14.5 5.7 301 8 300 165 -2.2 0 -2.1 -2.4 11/06/2005 22:50:00 9.9 1.8 14.9 6.5 9.8 1.8 14.5 6.1 8 1.5 12.2 4.6 299 8 296 165 -2.4 0 -2.1 -2.6 11/06/2005 23:00:00 11 1.5 16.1 8 10.9 1.6 16.4 7.6 9 1.3 14.1 5.7 304 8 305 165 -2.2 0 -2.1 -2.6 11/06/2005 23:10:00 11.4 1.5 15.6 7.6 11.3 1.5 15.3 7.2 9.3 1.5 13 5.3 306 7 305 165 -2.4 0 -2.1 -2.6 11/06/2005 23:20:00 13.7 1.5 17.2 10.3 13.5 1.5 17.2 10.3 10.8 1.7 15.3 6.8 303 8 298 165 -2.2 0 -2.1 -2.6 11/06/2005 23:30:00 12.8 1.5 16.4 9.9 12.7 1.5 16.4 9.9 10.1 1.3 14.9 7.2 304 7 306 165 -2.4 0.1 -2.1 -2.6 11/06/2005 23:40:00 12.3 1.3 14.9 9.1 12.2 1.3 15.3 8.8 10.1 1.5 14.1 6.8 306 7 311 165 -2.5 0 -2.4 -2.6 11/06/2005 23:50:00 10.6 1.5 14.5 6.8 10.5 1.5 14.5 6.8 9.3 1.9 14.1 5.3 307 8 310 165 -2.4 0 -2.1 -2.6 11/07/2005 00:00:00 12 1.2 14.9 9.1 11.9 1.2 15.3 8.4 10.9 1.6 14.9 6.8 310 9 323 165 -2.3 0 -2.1 -2.6 11/07/2005 00:10:00 12.1 1.7 16.1 7.6 12 1.7 16.1 7.2 10.2 2.1 16.1 5.7 305 8 305 165 -2.2 0 -2.1 -2.6 11/07/2005 00:20:00 9.6 1.6 14.1 5.3 9.5 1.6 14.1 5.3 8.5 1.5 13 4.9 308 10 308 165 -2.3 0 -2.1 -2.6 11/07/2005 00:30:00 9.5 1.7 14.9 6.1 9.3 1.7 14.5 5.7 8.1 1.5 12.6 4.9 308 13 293 165 -2.5 0 -2.1 -2.6 11/07/2005 00:40:00 10.2 1.3 13.3 7.2 10.1 1.2 13.3 6.8 9 1.7 13.3 4.9 309 8 319 165 -2.4 0 -2.1 -2.6 11/07/2005 00:50:00 11.3 1.5 15.6 7.6 11.2 1.5 15.3 7.2 9.8 1.5 14.1 6.1 304 11 305 165 -2.4 0 -2.1 -2.8 11/07/2005 01:00:00 11.3 1.5 14.9 7.2 11.2 1.5 14.9 7.2 9.7 1.7 13.7 5.3 307 8 297 165 -2.3 0 -2.1 -2.6 11/07/2005 01:10:00 12 2 16.1 7.2 11.9 2 16.4 7.2 9.9 1.7 15.3 6.1 298 10 281 165 -2.2 0 -2.1 -2.6 11/07/2005 01:20:00 12.5 1.3 15.3 8.8 12.4 1.3 15.6 8.4 10.7 1.6 16.1 6.5 305 9 317 165 -2.3 0 -2.1 -2.6 11/07/2005 01:30:00 12.7 1.3 16.1 9.5 12.6 1.3 16.4 8.8 10.3 1.5 14.9 6.8 302 8 301 165 -2.4 0 -2.1 -2.6 11/07/2005 01:40:00 13.1 1.6 17.2 7.2 13 1.6 16.8 8 10.4 1.8 15.3 6.1 302 8 315 165 -2.2 0 -2.1 -2.6 11/07/2005 01:50:00 12.6 1.7 17.2 8.4 12.5 1.8 16.8 8.4 10.3 1.7 14.5 6.8 303 8 299 165 -2.2 0 -2.1 -2.6 11/07/2005 02:00:00 11.7 1.9 16.8 7.2 11.6 1.8 16.4 7.2 9.4 1.7 15.3 6.1 301 9 300 165 -2.3 0 -2.1 -2.6 11/07/2005 02:10:00 11.4 1.8 15.3 6.5 11.2 1.7 15.3 6.5 9.3 1.7 13.7 6.1 303 9 302 165 -2.4 0 -2.1 -2.8 11/07/2005 02:20:00 9.3 1.7 14.1 5.3 9.2 1.7 14.1 5.7 8 1.6 12.6 4.6 309 10 309 165 -2.4 0 -2.1 -2.6 11/07/2005 02:30:00 9.4 1.5 13 6.1 9.3 1.5 13 6.1 8.5 1.5 12.2 5.3 314 9 312 165 -2.5 0 -2.1 -2.6 11/07/2005 02:40:00 10.2 1.2 13 7.6 10.1 1.2 13 7.2 9.7 1.3 13.3 6.8 317 9 315 165 -2.5 0 -2.6 -2.6 11/07/2005 02:50:00 9.4 1.2 12.6 6.1 9.3 1.2 12.6 6.1 8.4 1.3 12.2 5.3 312 9 314 165 -2.5 0 -2.1 -2.8 11/07/2005 03:00:00 9.5 1.9 14.1 4.9 9.4 1.9 14.1 4.6 8.5 1.6 13.3 5.3 313 11 307 165 -2.5 0 -2.4 -2.6 11/07/2005 03:10:00 9.7 1.8 14.5 4.9 9.6 1.8 14.1 5.3 8.7 1.9 13.7 3.8 312 9 306 165 -2.5 0 -2.4 -2.8 11/07/2005 03:20:00 9.8 1.1 12.2 6.1 9.7 1.1 11.8 6.5 8.9 1.2 11.8 5.3 312 10 300 165 -2.5 0 -2.4 -2.8 11/07/2005 03:30:00 8.5 1.2 11.8 5.7 8.4 1.2 11.8 5.3 7.1 1.3 10.3 3.8 303 8 295 165 -2.5 0 -2.4 -2.8 11/07/2005 03:40:00 7.8 1.5 11.8 4.2 7.7 1.6 11.8 4.2 6.7 1.3 11.1 4.2 303 10 287 165 -2.4 0 -2.1 -2.6 11/07/2005 03:50:00 7.5 1 10.7 5.3 7.4 1 11.1 5.3 7 1 10.7 4.6 314 8 297 165 -2.4 0 -2.1 -2.6 11/07/2005 04:00:00 7.7 1.5 11.8 4.6 7.6 1.4 11.8 3.8 6.9 1.3 10.3 3.8 310 10 301 165 -2.5 0 -2.4 -2.8 11/07/2005 04:10:00 5.9 1.2 10.3 3.4 5.8 1.2 9.9 3.4 5.1 1.1 8.4 3 304 12 286 165 -2.4 0 -2.1 -2.6 11/07/2005 04:20:00 5 0.9 7.6 3.4 5 0.9 7.6 3 4.4 0.9 7.2 2.6 301 17 322 165 -2.4 0 -2.1 -2.6 11/07/2005 04:30:00 5.9 0.9 8.4 3.4 5.7 0.9 7.6 3.4 5.6 1.1 8.8 3 319 10 323 165 -2.3 0 -2.1 -2.6 11/07/2005 04:40:00 7.1 1.4 10.7 3.4 6.9 1.4 10.7 3.4 7 1.4 11.1 4.6 322 9 324 165 -2.3 0 -2.1 -2.6 11/07/2005 04:50:00 7.5 0.8 9.5 5.7 7.4 0.8 9.5 5.7 7.1 1.1 9.9 4.2 315 8 314 165 -2.2 0 -2.1 -2.6 11/07/2005 05:00:00 8.5 0.8 10.3 6.5 8.4 0.8 9.9 6.1 7.9 1 9.9 4.9 317 8 318 165 -2.4 0.1 -2.1 -2.6 11/07/2005 05:10:00 8.1 0.7 9.5 5.7 7.9 0.7 9.5 5.7 7.2 1 9.5 4.6 307 9 319 165 -2.4 0 -2.1 -2.8 11/07/2005 05:20:00 11.6 1.1 13.7 8.4 11.5 1 13.7 8.4 9.8 1.7 13 6.1 308 6 306 165 -2.5 0 -2.1 -2.6 11/07/2005 05:30:00 10.3 1 12.6 8 10.1 0.9 12.2 8 9.1 1 11.5 6.1 309 6 308 165 -2.5 0 -2.4 -2.8 11/07/2005 05:40:00 11 1.2 13.3 6.5 10.8 1.2 13.3 6.8 10.4 1.5 12.6 6.5 322 6 324 165 -2.8 0 -2.6 -3 11/07/2005 05:50:00 9.5 1.1 11.8 7.2 9.3 1.1 11.8 7.2 8.6 1 11.8 5.7 316 8 322 165 -2.9 0 -2.8 -3 11/07/2005 06:00:00 9.3 1.5 13 6.1 9.2 1.4 13 6.1 8.4 1.7 12.6 4.6 317 7 321 165 -3 0.1 -2.8 -3.3 11/07/2005 06:10:00 6.4 1.5 11.1 2.6 6.3 1.5 11.1 2.6 5.4 1.6 9.5 1.5 317 12 312 165 -3 0 -2.8 -3.3 11/07/2005 06:20:00 7.5 1 9.9 4.2 7.5 1 9.5 4.6 5.9 1.3 8.8 1.9 307 9 297 165 -3.1 0 -3 -3.3 11/07/2005 06:30:00 4.5 1.7 9.1 0.4 4.4 1.8 9.1 0.4 3.4 1.5 8.4 0.4 313 22 307 165 -3 0 -2.8 -3.3 11/07/2005 06:40:00 4.2 1.2 6.8 1.5 4 1.2 6.8 0.7 3.3 1.3 6.8 0.4 324 24 340 165 -3 0 -2.8 -3.3 11/07/2005 06:50:00 4.4 1.5 7.6 1.1 4.2 1.5 7.6 0.7 4 1.6 6.8 0.4 323 19 315 165 -3.1 0 -3 -3.3 11/07/2005 07:00:00 1.5 1.1 4.9 0.4 1.2 1.1 4.6 0.4 1.5 0.9 4.2 0.4 307 38 321 165 -3 0 -2.8 -3.5 11/07/2005 07:10:00 1.3 1.1 4.2 0.4 1.2 1.2 4.6 0.4 1.5 1.4 4.9 0.4 294 28 253 165 -3 0.1 -2.8 -3.3 11/07/2005 07:20:00 1.4 0.6 3 0.4 1 0.6 2.6 0.4 1.3 0.6 2.6 0.4 7 29 40 165 -3.2 0 -3 -3.5 11/07/2005 07:30:00 1 0.7 3 0.4 0.8 0.6 2.6 0.4 1.1 0.6 3 0.4 349 90 64 165 -3.3 0 -3.3 -3.5 11/07/2005 07:40:00 1.6 0.6 2.6 0.4 1.2 0.6 2.6 0.4 1.9 0.5 3 0.7 44 23 26 165 -3.4 0 -3.3 -3.5 11/07/2005 07:50:00 2.2 0.2 2.6 1.5 2 0.3 2.6 1.1 2.5 0.3 3.4 1.9 38 7 39 165 -3.6 0 -3.5 -3.7 11/07/2005 08:00:00 2.6 0.3 3.4 1.5 1.8 0.7 3 0.4 2.9 0.4 3.8 1.9 11 15 36 165 -3.7 0 -3.5 -3.9 11/07/2005 08:10:00 2.8 0.3 3.8 2.3 1.3 0.5 3 0.4 3 0.3 4.2 2.3 0 5 3 165 -3.8 0 -3.7 -3.9 11/07/2005 08:20:00 2.8 0.4 3.4 1.9 2.4 0.6 3.8 0.7 2.8 0.4 3.4 1.9 340 6 355 165 -3.9 0 -3.7 -4.2 11/07/2005 08:30:00 2.5 0.4 3.4 1.5 1.6 0.8 3.8 0.4 2.6 0.4 3.4 1.9 350 3 344 165 -3.9 0 -3.7 -4.2 11/07/2005 08:40:00 2.8 0.6 3.8 1.9 1.2 0.4 2.3 0.4 3 0.7 4.2 1.9 0 3 0 165 -3.9 0 -3.7 -4.2 11/07/2005 08:50:00 3.7 0.4 4.6 3 2.3 0.7 4.2 1.1 4 0.3 4.9 3.4 7 4 5 165 -3.7 0.1 -3.5 -3.9 11/07/2005 09:00:00 3.7 0.2 4.2 3.4 2.6 0.6 3.8 1.5 4 0.2 4.6 3.4 10 5 9 165 -3.6 0 -3.5 -3.7 11/07/2005 09:10:00 3.6 0.4 4.6 2.6 3.6 0.4 4.6 2.6 3.9 0.4 4.9 3 30 3 28 165 -3.5 0 -3.3 -3.5 11/07/2005 09:20:00 2.1 0.6 3.4 0.7 1.8 0.7 3 0.4 2.3 0.7 3.4 1.1 25 4 22 165 -3.3 0 -3.3 -3.5 11/07/2005 09:30:00 2 0.3 2.3 1.5 1.3 0.4 2.3 0.4 2.1 0.2 2.6 1.5 16 5 14 165 -3.3 0 -3.3 -3.5 11/07/2005 09:40:00 2.5 0.2 3 1.9 2.4 0.3 3 1.5 2.6 0.4 3.4 1.9 37 6 41 165 -3.2 0 -3 -3.5 11/07/2005 09:50:00 2.5 0.2 3 1.9 2.3 0.3 2.6 1.5 2.6 0.3 3 1.9 31 2 35 165 -3.1 0 -3 -3.3 11/07/2005 10:00:00 2 0.5 3 0.7 1.7 0.6 3 0.4 2.2 0.5 3 1.1 37 3 35 165 -3 0 -3 -3.3 11/07/2005 10:10:00 1 0.4 1.9 0.4 0.7 0.4 1.5 0.4 1.3 0.5 2.3 0.4 73 22 54 165 -3 0 -2.8 -3.3 11/07/2005 10:20:00 0.5 0.3 1.9 0.4 0.4 0.1 1.1 0.4 0.6 0.3 1.9 0.4 84 8 66 165 -2.8 0 -2.6 -3 11/07/2005 10:30:00 1.5 0.5 2.6 0.4 1.2 0.6 2.3 0.4 1.6 0.5 2.6 0.4 62 14 49 165 -2.7 0 -2.6 -2.8 11/07/2005 10:40:00 1.7 0.4 2.6 0.4 1.4 0.5 2.6 0.4 1.7 0.4 3 0.7 57 12 40 165 -2.8 0 -2.6 -2.8 11/07/2005 10:50:00 2 0.4 2.6 0.7 1.7 0.5 2.6 0.4 1.9 0.4 3 1.1 38 11 39 165 -2.6 0 -2.6 -2.8 11/07/2005 11:00:00 2 0.3 2.6 1.1 1.8 0.4 2.6 0.4 2.1 0.4 2.6 1.1 39 10 27 165 -2.6 0 -2.6 -2.8 11/07/2005 11:10:00 1.8 0.3 2.3 1.1 1.6 0.4 2.3 0.7 1.8 0.4 2.6 1.1 66 5 57 165 -2.6 0 -2.6 -2.8 11/07/2005 11:20:00 1.5 0.4 2.3 0.4 1.2 0.5 2.3 0.4 1.5 0.4 2.3 0.7 58 11 48 165 -2.5 0 -2.4 -2.8 11/07/2005 11:30:00 1.2 0.6 2.3 0.4 0.9 0.6 2.3 0.4 1.3 0.6 2.3 0.4 77 28 98 165 -2.5 0 -2.4 -2.6 11/07/2005 11:40:00 2.5 0.6 3.8 1.1 2.3 0.7 3.8 0.7 2.6 0.7 3.8 0.4 37 8 41 165 -2.5 0 -2.4 -2.6 11/07/2005 11:50:00 3.4 0.4 4.2 2.3 3.3 0.5 4.2 1.9 3.5 0.4 4.2 2.3 37 5 43 165 -2.5 0 -2.6 -2.6 11/07/2005 12:00:00 3.9 0.4 4.9 2.6 3.9 0.5 4.9 2.6 3.8 0.5 4.9 2.6 40 7 34 165 -2.6 0 -2.6 -2.8 11/07/2005 12:10:00 5.1 0.8 6.5 3 5 0.9 6.8 3 5.2 0.8 7.2 3 35 9 45 165 -2.7 0.1 -2.6 -3 11/07/2005 12:20:00 5.5 0.5 6.8 3.8 5.5 0.6 6.8 3.8 5.6 0.6 7.6 4.2 37 6 46 165 -3 0 -2.8 -3.3 11/07/2005 12:30:00 5.3 0.7 6.5 3.4 5.2 0.7 6.8 3.4 5.4 0.8 6.8 3.4 32 8 41 165 -3 0 -2.8 -3.3 11/07/2005 12:40:00 5.8 0.5 7.2 4.2 5.8 0.6 7.2 4.2 6 0.7 8 4.2 34 6 18 165 -3 0 -2.8 -3.3 11/07/2005 12:50:00 6.4 0.8 8 4.2 6.4 0.8 8 4.2 6.4 0.9 8.4 3.8 31 6 29 165 -3.2 0 -3 -3.3 11/07/2005 13:00:00 6 0.9 7.6 3.8 5.9 1 7.6 3.4 6 1 8 3.4 29 7 34 165 -3.3 0 -3.3 -3.5 11/07/2005 13:10:00 6.7 0.5 8.4 4.9 6.6 0.6 8 4.6 6.6 0.6 8.4 4.9 30 5 31 165 -3.5 0.1 -3.3 -3.5 11/07/2005 13:20:00 6.1 0.8 8.4 3.8 6 0.9 8.4 3.4 6.1 0.8 7.6 3.4 26 8 20 165 -3.6 0 -3.5 -3.7 11/07/2005 13:30:00 6.9 0.5 8.4 5.3 6.7 0.6 8.4 4.9 6.9 0.6 8.4 4.9 25 6 13 165 -3.6 0 -3.5 -3.5 11/07/2005 13:40:00 6.4 0.9 8.4 4.2 6.3 1 8.4 3.4 6.4 1 8.4 3.8 29 7 23 165 -3.7 0 -3.5 -3.7 11/07/2005 13:50:00 6.2 0.9 8.8 4.2 6 1 8.4 3.4 6 1 8.4 4.2 24 7 17 165 -3.7 0 -3.5 -3.9 11/07/2005 14:00:00 6.5 0.6 7.6 4.6 6.4 0.6 7.6 4.2 6.4 0.6 8 4.6 29 5 36 165 -3.7 0 -3.5 -3.9 11/07/2005 14:10:00 6.4 0.5 7.6 4.2 6.2 0.6 7.6 4.2 6.4 0.6 7.6 4.6 26 5 31 165 -3.8 0 -3.5 -3.9 11/07/2005 14:20:00 6.5 0.7 8.4 4.2 6.1 0.8 7.6 3.4 6.5 0.7 8 4.6 19 6 12 165 -3.7 0 -3.5 -3.9 11/07/2005 14:30:00 6.3 0.7 8 4.2 6.1 0.8 8 3.8 6.2 0.6 7.6 4.6 26 6 31 165 -3.8 0 -3.7 -3.9 11/07/2005 14:40:00 6.1 0.5 7.2 4.6 5.7 0.6 7.2 3.8 6 0.6 7.6 4.2 21 7 28 165 -3.9 0 -3.7 -4.2 11/07/2005 14:50:00 6.1 0.6 7.2 4.6 5.6 0.8 7.2 2.6 6 0.6 7.6 4.2 18 6 14 165 -4 0 -3.9 -4.2 11/07/2005 15:00:00 6.4 0.5 7.2 4.9 5.9 0.6 7.2 3.8 6.3 0.6 7.6 4.6 18 5 21 165 -4.2 0 -3.9 -4.4 11/07/2005 15:10:00 6.1 0.5 7.6 4.9 5.3 0.8 6.8 2.6 6.2 0.6 8 4.2 14 5 15 165 -4.3 0 -4.2 -4.4 11/07/2005 15:20:00 6.5 0.6 7.6 4.6 5.5 1 7.2 3 6.5 0.5 7.6 4.9 12 6 17 165 -4.3 0 -4.2 -4.6 11/07/2005 15:30:00 6.9 0.4 7.6 5.7 6.2 0.6 7.2 4.2 6.8 0.5 8 5.3 14 3 17 165 -4.2 0 -4.2 -4.6 11/07/2005 15:40:00 7.3 0.6 8.8 5.3 6.4 0.9 8 3.4 7.2 0.7 8.4 5.3 13 4 14 165 -4.2 0 -3.9 -4.4 11/07/2005 15:50:00 6.9 0.5 8 5.3 5.8 0.9 7.6 3 6.8 0.6 8.4 5.3 12 4 5 165 -4.2 0 -3.9 -4.4 11/07/2005 16:00:00 7.2 0.7 8.8 4.9 6.1 1 8 3.4 7.2 0.7 8.8 5.3 12 5 14 165 -4.2 0 -3.9 -4.4 11/07/2005 16:10:00 7.5 0.6 9.1 6.1 6 1.1 8.4 3 7.4 0.7 9.1 5.7 10 4 4 165 -4.2 0 -4.2 -4.4 11/07/2005 16:20:00 8.1 0.6 9.5 6.8 6.6 1.1 8.8 4.2 8 0.6 9.5 6.1 11 3 12 165 -4.3 0 -4.2 -4.4 11/07/2005 16:30:00 7.5 0.5 8.8 5.7 5.7 1 8 3.4 7.4 0.5 8.8 6.1 9 5 11 165 -4.3 0 -4.2 -4.6 11/07/2005 16:40:00 7.6 0.7 9.5 5.7 5.6 1.1 8.8 3 7.6 0.7 9.9 5.7 8 4 12 165 -4.3 0 -4.2 -4.4 11/07/2005 16:50:00 7 0.7 8.8 5.3 5.3 1.1 8.4 3 7 0.8 9.1 4.9 8 6 12 165 -4.2 0 -4.2 -4.4 11/07/2005 17:00:00 6.6 0.7 8.4 4.9 5.6 0.9 8 2.6 6.3 0.8 8.8 3.8 14 8 12 165 -4.2 0 -3.9 -4.4 11/07/2005 17:10:00 6.4 0.8 8.4 4.6 6.2 0.9 8.4 4.2 6.2 0.9 8.4 3.8 22 7 16 165 -4.1 0 -3.9 -4.4 11/07/2005 17:20:00 5.3 0.8 7.6 3.8 5 1 7.6 2.6 5.1 0.7 7.2 3.4 26 10 40 165 -3.9 0 -3.7 -4.4 11/07/2005 17:30:00 6.1 0.9 8.4 3.8 5.9 0.9 8 3.4 6 0.9 8 3.8 32 8 46 165 -3.9 0 -3.7 -4.2 11/07/2005 17:40:00 6.9 1.1 9.1 3.4 6.8 1.2 9.5 2.6 6.7 1.2 9.9 3.8 31 8 31 165 -3.8 0 -3.7 -4.2 11/07/2005 17:50:00 6.7 0.9 8.8 4.6 6.5 1 8.8 3.4 6.4 1 8.8 3.8 28 8 34 165 -3.8 0 -3.5 -3.9 11/07/2005 18:00:00 7.5 0.8 9.1 5.3 7.4 0.8 9.1 4.9 7.1 0.9 9.1 4.9 34 7 31 165 -4 0.1 -3.9 -4.2 11/07/2005 18:10:00 7.7 0.7 9.1 5.3 7.6 0.8 9.1 4.9 7.3 0.8 9.5 4.9 34 6 28 165 -4.1 0 -3.9 -4.4 11/07/2005 18:20:00 6.4 1 8.4 4.2 6.2 1 8.4 4.2 6.2 1 8.4 4.2 31 8 36 165 -4 0 -3.9 -4.4 11/07/2005 18:30:00 6.7 1 8.8 3.8 6.4 1.1 8.8 3.8 6.5 1 8.8 4.2 26 9 41 165 -4.2 0 -3.9 -4.4 11/07/2005 18:40:00 7.2 0.8 9.1 4.9 6.1 1 8.4 3.4 7 0.9 9.1 4.6 13 8 10 165 -4.3 0 -4.2 -4.4 11/07/2005 18:50:00 5.1 1 7.6 3 4.8 1 6.8 2.6 4.9 0.9 7.2 3 21 8 5 165 -4.3 0 -4.2 -4.6 11/07/2005 19:00:00 5.8 1.1 8.4 3.4 5.2 1 8 2.6 5.5 1 8.4 3.4 17 9 357 165 -4.3 0 -4.2 -4.4 11/07/2005 19:10:00 7 1.2 9.9 4.2 6.2 1.2 8.8 3.4 6.7 1.2 9.1 4.2 16 7 15 165 -4.3 0 -4.2 -4.6 11/07/2005 19:20:00 7.4 0.8 9.1 4.9 6.7 1 9.1 3.8 7 0.9 9.1 4.9 18 7 11 165 -4.5 0 -4.4 -4.6 11/07/2005 19:30:00 7.8 1 10.7 5.3 6.7 1.2 10.3 3.4 7.6 0.9 10.3 5.3 14 6 18 165 -4.6 0 -4.4 -4.8 11/07/2005 19:40:00 8 1 10.3 5.7 6.7 1.2 9.9 3.8 7.8 1.1 10.3 4.9 12 7 6 165 -4.7 0 -4.6 -4.8 11/07/2005 19:50:00 8 0.9 9.9 5.3 7.1 1.1 9.1 3.8 7.8 1 9.9 4.9 14 6 16 165 -4.7 0 -4.6 -4.8 11/07/2005 20:00:00 7.7 1 9.9 5.3 6.3 1.4 9.5 3 7.5 0.9 10.7 4.9 11 8 18 165 -4.7 0 -4.6 -4.8 11/07/2005 20:10:00 7.6 0.8 9.5 5.7 5.9 1 8.4 3.8 7.4 0.9 9.5 5.3 10 6 9 165 -4.7 0 -4.6 -4.8 11/07/2005 20:20:00 7.2 0.8 9.1 5.3 5.7 1.3 8.4 2.6 7 0.9 9.1 4.9 11 6 19 165 -4.7 0 -4.6 -5 11/07/2005 20:30:00 6.8 0.9 8.8 4.6 5.7 1 8.4 3 6.6 1 8.8 4.2 12 7 10 165 -4.7 0 -4.6 -5 11/07/2005 20:40:00 7.1 0.7 8.8 5.3 5.4 1 8 3 6.9 0.7 8.4 5.3 8 6 15 165 -4.7 0 -4.6 -4.8 11/07/2005 20:50:00 7 0.8 9.1 4.9 5 1 7.6 2.6 6.9 0.9 9.1 4.9 8 5 9 165 -4.7 0 -4.6 -4.8 11/07/2005 21:00:00 6.1 0.7 8 4.2 4.7 0.8 6.8 2.6 6 0.8 8 4.6 9 5 6 165 -4.7 0 -4.6 -5 11/07/2005 21:10:00 6.1 0.7 8 4.9 4.4 1 6.8 2.3 6 0.8 8 4.2 7 6 7 165 -4.7 0 -4.6 -4.8 11/07/2005 21:20:00 6.3 1 8.4 4.2 4.9 1.2 7.6 2.3 6.1 1.1 8.8 3.8 10 7 9 165 -4.8 0 -4.6 -5 11/07/2005 21:30:00 7.1 1 9.9 4.6 5.9 1.3 9.5 3.4 7 1.1 9.9 4.6 12 7 19 165 -4.8 0 -4.6 -5 11/07/2005 21:40:00 6.8 0.7 8.4 4.9 5.7 1 8 3.4 6.6 0.8 8.4 4.2 12 6 12 165 -4.7 0 -4.6 -4.8 11/07/2005 21:50:00 7.2 0.7 8.8 4.9 6.1 1 8 3.4 7 0.8 9.1 4.9 13 6 7 165 -4.7 0 -4.6 -4.8 11/07/2005 22:00:00 7.5 0.9 9.1 4.6 5.7 1.2 8.8 2.6 7.4 0.9 9.1 4.6 9 6 11 165 -4.7 0 -4.6 -4.8 11/07/2005 22:10:00 7.6 0.7 9.5 6.1 5.2 1.2 8.4 3 7.7 0.8 9.5 5.7 6 5 11 165 -4.7 0 -4.6 -4.8 11/07/2005 22:20:00 6.7 0.6 8 5.3 4.2 0.9 6.8 2.6 6.7 0.6 8 4.9 1 6 0 165 -4.8 0 -4.6 -5 11/07/2005 22:30:00 6.4 0.7 8 3.4 4.3 0.9 6.5 2.6 6.2 0.7 8.4 4.6 359 8 3 165 -4.9 0 -4.6 -5 11/07/2005 22:40:00 7.4 0.7 8.8 4.9 4.5 1 7.6 2.6 7.3 0.8 8.8 4.9 2 6 8 165 -4.8 0 -4.6 -5 11/07/2005 22:50:00 7.3 0.6 8.8 6.1 4.7 0.9 8 3 7.2 0.6 9.5 5.7 1 6 357 165 -4.7 0 -4.6 -4.8 11/07/2005 23:00:00 6.9 0.6 8.8 5.7 5.5 1 7.6 3 6.8 0.6 8.4 4.9 352 4 357 165 -4.6 0 -4.4 -4.8 11/07/2005 23:10:00 6.6 0.8 8.8 4.6 5 1.2 8.4 2.6 6.2 0.8 8.4 4.2 353 8 352 165 -4.6 0 -4.4 -4.8 11/07/2005 23:20:00 6.4 1.1 9.9 4.2 4.2 1.1 7.6 2.3 6.3 1 9.1 4.6 0 6 356 165 -4.6 0 -4.4 -4.8 11/07/2005 23:30:00 5.7 0.5 7.2 4.2 4.1 1 6.8 2.6 5.5 0.6 6.8 3.8 357 9 353 165 -4.5 0 -4.4 -4.6 11/07/2005 23:40:00 6.2 0.6 8 4.6 4.5 1.2 8 2.3 6 0.7 8.4 3.8 354 7 357 165 -4.5 0 -4.4 -4.8 11/07/2005 23:50:00 5.5 0.5 6.8 4.2 4.2 1 6.5 1.9 5.4 0.6 6.8 3.8 353 7 356 165 -4.5 0 -4.4 -4.8 11/08/2005 00:00:00 4.7 0.8 7.2 2.6 4 1.1 7.2 1.5 4.4 0.7 6.8 2.6 348 9 347 165 -4.5 0 -4.4 -4.6 11/08/2005 00:10:00 4.3 0.7 6.5 2.6 3.6 1 6.5 1.5 4.2 0.6 5.7 3 350 8 349 165 -4.4 0 -4.4 -4.6 11/08/2005 00:20:00 4.9 0.6 6.5 3.4 4.2 0.8 5.7 1.9 4.6 0.6 6.5 3 346 9 355 165 -4.4 0 -4.4 -4.6 11/08/2005 00:30:00 5.1 0.6 6.8 3.4 4.5 1 6.8 2.3 4.9 0.6 6.8 3.4 347 8 345 165 -4.3 0 -4.4 -4.6 11/08/2005 00:40:00 5.1 0.6 7.2 3.8 4.7 0.7 6.8 2.3 4.9 0.6 7.2 3.4 342 8 349 165 -4.3 0 -4.2 -4.6 11/08/2005 00:50:00 5.9 0.6 7.2 4.2 5.6 0.9 7.6 2.6 5.7 0.7 7.6 4.2 345 6 347 165 -4.2 0 -4.2 -4.4 11/08/2005 01:00:00 5.2 0.6 6.5 3.8 4.5 1 6.5 2.3 5.1 0.6 6.8 3.8 348 7 336 165 -4.2 0 -3.9 -4.4 11/08/2005 01:10:00 6.1 0.8 8 3.8 5.2 0.9 8.4 3 6 0.8 8 4.2 348 8 358 165 -4 0 -3.9 -4.4 11/08/2005 01:20:00 6.7 0.9 9.5 4.6 5.9 1.1 8.4 3 6.5 0.8 9.1 4.9 350 8 14 165 -3.9 0 -3.7 -4.4 11/08/2005 01:30:00 7.7 0.8 9.9 5.3 6.5 1.2 9.1 3.4 7.7 0.8 9.5 5.3 351 7 12 165 -3.9 0 -3.7 -3.9 11/08/2005 01:40:00 6.6 1 9.5 3.4 5.3 1.2 8.8 2.6 6.4 0.9 8.8 3.8 356 9 3 165 -3.8 0 -3.5 -4.2 11/08/2005 01:50:00 8.1 1 9.9 5.3 6.3 1.3 9.9 3.4 7.8 1 9.9 4.9 8 8 26 165 -3.2 0.2 -2.8 -3.7 11/08/2005 02:00:00 8 0.8 9.9 6.1 7.2 1 9.5 3.4 7.6 0.9 9.9 5.3 15 7 11 165 -2.9 0 -2.8 -3 11/08/2005 02:10:00 7.1 0.6 8.4 4.9 6.1 0.9 8 3.8 7 0.6 8.8 5.7 15 6 16 165 -2.8 0 -2.8 -3 11/08/2005 02:20:00 7 0.6 8.8 4.6 5.7 1 8 3 6.8 0.7 8.8 4.9 11 5 0 165 -2.8 0 -2.6 -3 11/08/2005 02:30:00 6.4 1 8.8 4.2 5 1.2 8 2.3 6.2 1 8.4 4.2 9 7 357 165 -2.6 0 -2.6 -3 11/08/2005 02:40:00 6.7 0.7 8.4 5.3 5.5 1 7.6 3 6.5 0.8 8.4 4.2 11 5 9 165 -2.5 0 -2.6 -2.8 11/08/2005 02:50:00 7.7 0.8 9.9 5.7 6.3 1 9.5 3.4 7.5 0.8 9.1 5.7 11 5 14 165 -2.5 0 -2.6 -2.8 11/08/2005 03:00:00 7.7 1.1 10.3 5.7 6.6 1.3 10.3 3.8 7.7 1.1 10.3 4.9 14 5 14 165 -2.5 0 -2.6 -2.8 11/08/2005 03:10:00 6.9 1.1 9.1 4.9 4.9 1.7 8.8 2.6 6.9 1 9.1 4.9 4 8 19 165 -2.5 0 -2.4 -2.6 11/08/2005 03:20:00 5.8 0.4 7.2 4.9 3.6 0.7 5.7 2.3 5.9 0.4 7.2 4.9 359 6 5 165 -2.6 0 -2.6 -2.8 11/08/2005 03:30:00 6.1 0.5 7.6 4.9 4.2 1.1 7.2 2.3 6.1 0.5 7.6 4.6 355 5 0 165 -2.6 0 -2.6 -2.8 11/08/2005 03:40:00 6.9 0.7 8.4 4.6 5.8 1.2 8 3 6.8 0.6 8 4.6 351 6 359 165 -2.5 0 -2.6 -2.8 11/08/2005 03:50:00 7.1 0.6 9.5 5.7 6.7 1.1 9.5 3.4 7.1 0.6 9.1 5.7 345 6 347 165 -2.5 0 -2.6 -2.8 11/08/2005 04:00:00 8.1 1 9.9 5.3 8 1.2 10.3 3.4 8.1 0.9 9.9 5.7 342 7 346 165 -2.5 0 -2.6 -2.6 11/08/2005 04:10:00 8.9 1 11.1 6.1 8.9 1.2 11.5 5.7 8.9 1.2 12.2 6.1 341 6 349 165 -2.5 0 -2.6 -2.8 11/08/2005 04:20:00 8.5 1 11.1 5.7 8.4 1 11.1 5.3 8.3 0.9 11.8 5.7 338 7 342 165 -2.5 0 -2.1 -2.6 11/08/2005 04:30:00 8.5 0.7 10.3 6.8 8.4 1 11.1 4.6 8.5 0.7 10.3 6.1 341 7 338 165 -2.4 0 -2.1 -2.6 11/08/2005 04:40:00 7.9 1 10.3 5.7 7.9 1.1 10.7 4.6 7.7 1 9.9 5.3 339 7 336 165 -2.2 0 -2.1 -2.6 11/08/2005 04:50:00 7.5 0.6 9.1 5.7 7.2 1 9.1 3.4 7.4 0.7 9.5 5.7 344 8 340 165 -2.1 0 -1.9 -2.6 11/08/2005 05:00:00 7.3 0.7 9.1 5.7 6.9 1 9.9 3.8 7.2 0.7 9.9 5.7 345 6 345 165 -2 0 -1.9 -2.1 11/08/2005 05:10:00 7.8 0.8 10.7 5.7 7.3 1.3 10.7 3.4 7.7 0.9 10.3 5.7 348 5 349 165 -2 0 -1.9 -2.1 11/08/2005 05:20:00 7.4 0.7 9.5 5.3 7.3 0.9 9.5 3.8 7.3 0.7 9.1 5.3 341 7 342 165 -2 0 -1.9 -2.1 11/08/2005 05:30:00 7.9 0.9 10.3 5.7 7.2 1.3 10.7 4.6 7.9 1 10.7 5.3 348 7 340 165 -1.9 0 -1.7 -2.1 11/08/2005 05:40:00 6.7 0.7 8.8 4.6 6.3 1.1 8.8 3 6.5 0.9 8.8 4.2 343 9 354 165 -1.7 0 -1.4 -2.1 11/08/2005 05:50:00 7.3 1 10.3 4.9 7.1 1.2 10.7 3.4 7.2 0.8 9.5 5.3 340 7 341 165 -1.6 0 -1.4 -1.9 11/08/2005 06:00:00 7.6 0.7 9.5 6.1 7.5 0.9 9.5 4.9 7.5 0.7 9.5 5.3 342 8 340 165 -1.4 0 -1.2 -1.7 11/08/2005 06:10:00 7.1 0.7 8.8 5.3 6.8 0.9 8.8 3.8 7 0.8 8.8 5.3 344 7 341 165 -1.4 0 -1.2 -1.4 11/08/2005 06:20:00 6.9 0.8 8.8 4.2 5.5 1.2 8 2.3 6.9 0.8 9.1 4.2 352 8 357 165 -1.3 0 -1.2 -1.4 11/08/2005 06:30:00 6.9 0.7 8.8 5.3 5.7 1.4 8.4 2.6 6.8 0.6 8.8 5.3 350 7 349 165 -1.3 0 -1.2 -1.4 11/08/2005 06:40:00 7.4 0.7 9.1 5.3 6.4 1.3 9.1 3.4 7.2 0.7 9.1 5.3 348 9 355 165 -1.3 0 -1.2 -1.4 11/08/2005 06:50:00 6.8 0.6 8.8 5.3 6.5 0.8 8 3.4 6.8 0.6 8.4 5.3 345 6 346 165 -1.3 0 -1.2 -1.4 11/08/2005 07:00:00 6.5 0.6 8.4 4.9 6.3 0.8 8.4 3.8 6.4 0.6 8 4.9 344 6 337 165 -1.3 0 -1.2 -1.4 11/08/2005 07:10:00 7.3 0.7 9.5 4.9 6.2 1.2 8.8 3.8 7.2 0.8 8.8 4.9 351 6 356 165 -1.2 0 -1 -1.4 11/08/2005 07:20:00 5.8 0.6 7.2 4.6 4.3 1 6.8 2.6 5.9 0.6 7.2 4.6 353 6 0 165 -1 0 -0.8 -1.4 11/08/2005 07:30:00 6.1 0.6 8 4.6 4.2 0.9 7.2 2.6 6 0.6 7.6 4.6 357 6 3 165 -0.7 0 -0.5 -1.2 11/08/2005 07:40:00 6 0.7 7.6 3.8 4 0.9 6.5 2.3 6.1 0.7 8 3.8 356 7 4 165 -0.5 0 -0.3 -0.8 11/08/2005 07:50:00 7.2 0.7 9.1 5.3 4.9 1.2 8 3 7.1 0.7 8.4 5.3 1 7 14 165 -0.3 0.1 -0.1 -0.5 11/08/2005 08:00:00 6.7 0.7 8.4 5.3 5.8 1.1 8 3 6.6 0.7 8.4 4.9 349 7 3 165 -0.3 0 -0.1 -0.5 11/08/2005 08:10:00 6.2 0.7 8 4.6 5.8 1.1 8 2.3 6 0.7 8 4.6 344 8 338 165 -0.5 0 -0.3 -0.5 11/08/2005 08:20:00 6.8 0.7 9.1 4.9 6.4 1.1 9.5 3 6.8 0.6 9.1 5.7 346 6 354 165 -0.4 0 -0.3 -0.5 11/08/2005 08:30:00 7.2 0.8 9.9 5.7 6.8 1 8.8 4.2 7.1 0.9 9.5 5.3 347 6 352 165 -0.5 0 -0.3 -0.8 11/08/2005 08:40:00 7.1 0.9 9.9 5.3 6.5 1.4 10.3 3 7 0.9 9.9 4.6 347 7 340 165 -0.5 0 -0.3 -0.5 11/08/2005 08:50:00 6.6 0.7 9.1 4.6 5.9 1.2 8.4 3 6.5 0.7 8.4 4.9 348 8 335 165 -0.3 0 -0.3 -0.5 11/08/2005 09:00:00 6.7 0.8 9.1 4.9 5.1 1.4 9.1 2.6 6.6 0.8 9.1 4.6 352 8 358 165 -0.3 0 -0.3 -0.5 11/08/2005 09:10:00 6.9 0.7 8.8 4.6 5.3 1.1 7.6 2.6 6.7 0.7 8.8 4.9 358 10 5 165 -0.2 0 -0.1 -0.5 11/08/2005 09:20:00 6.7 0.6 9.1 4.9 4.9 1.3 8.8 2.6 6.6 0.6 8.4 5.3 356 9 16 165 0 0.1 0.2 -0.5 11/08/2005 09:30:00 7 0.8 8.8 5.3 6.2 1.3 8.8 3 7.1 0.8 8.8 5.3 349 6 344 165 0.2 0 0.2 0.2 11/08/2005 09:40:00 7.3 0.8 9.5 5.3 6 1.4 9.5 3 7.3 0.7 9.1 6.1 352 8 342 165 0.1 0 0.2 -0.1 11/08/2005 09:50:00 7.7 0.8 9.5 5.7 5.7 1.2 8.4 2.6 7.9 0.9 9.5 5.3 355 6 354 165 0.2 0 0.2 -0.1 11/08/2005 10:00:00 8.3 1.5 12.2 5.7 6.5 1.9 11.5 3.4 8.1 1.5 12.2 4.9 7 9 8 165 0.6 0.3 1.1 -0.1 11/08/2005 10:10:00 8.2 1 11.1 5.3 6 1.2 9.9 3.4 8 1 11.1 5.7 4 9 7 165 0.9 0.1 1.1 0.9 11/08/2005 10:20:00 8.5 1.1 11.1 5.7 6.3 1.4 9.5 3.4 8.4 1.2 11.1 4.9 6 7 15 165 0.9 0 1.1 0.7 11/08/2005 10:30:00 8 1 11.5 5.7 5.9 1.3 9.1 3.4 7.8 1 11.1 5.7 5 8 1 165 0.9 0 1.1 0.9 11/08/2005 10:40:00 8.3 1 11.1 6.1 6.5 1.5 10.3 3 8.3 1.1 11.5 5.7 10 7 19 165 0.8 0 0.9 0.9 11/08/2005 10:50:00 7.8 0.9 10.3 6.1 6.1 1.3 9.5 3.4 7.7 1 10.7 5.3 11 5 14 165 0.8 0 0.9 0.7 11/08/2005 11:00:00 8.5 0.9 10.7 6.1 7.1 1.2 9.5 3.8 8.3 0.9 10.7 5.7 14 5 15 165 0.9 0 1.1 0.7 11/08/2005 11:10:00 7.7 0.6 9.9 5.7 6.4 1 8.8 2.6 7.6 0.7 9.1 5.7 14 5 15 165 0.9 0 0.9 0.9 11/08/2005 11:20:00 8.3 0.7 9.9 6.1 7.3 0.9 9.1 4.9 8.1 0.7 9.5 5.3 16 5 9 165 1 0 1.4 0.9 11/08/2005 11:30:00 7.8 0.7 9.5 5.7 7 0.9 9.1 3.4 7.7 0.7 9.5 6.1 16 5 14 165 1.2 0 1.4 0.9 11/08/2005 11:40:00 7.9 0.7 9.5 6.1 6.6 1.1 8.8 3 7.7 0.7 9.5 5.7 14 6 16 165 1.2 0 1.4 0.9 11/08/2005 11:50:00 8.7 0.8 10.3 6.5 7.7 1 9.5 4.9 8.6 0.9 10.7 6.5 16 5 14 165 1.1 0 1.4 0.9 11/08/2005 12:00:00 8.3 0.6 9.5 6.8 7.1 0.7 8.8 4.9 8.1 0.6 9.9 6.1 15 3 11 165 1 0 1.4 0.9 11/08/2005 12:10:00 7.9 0.7 10.3 6.1 6.8 0.8 8.8 3.4 7.7 0.7 9.9 6.1 14 4 12 165 1.1 0 1.4 0.9 11/08/2005 12:20:00 8.7 0.7 10.3 6.8 7.6 1 9.9 4.9 8.4 0.9 10.7 6.5 15 5 12 165 1.2 0 1.4 0.9 11/08/2005 12:30:00 8.4 1 11.5 6.1 6.4 1.7 10.3 3.4 8.4 1 11.8 6.1 7 9 19 165 1.1 0 1.4 0.9 11/08/2005 12:40:00 7.6 0.6 9.1 6.1 5.9 1.3 9.5 3.4 7.7 0.7 9.1 6.1 353 6 346 165 0.9 0.1 1.1 0.7 11/08/2005 12:50:00 7.9 0.8 9.9 5.7 6.5 1.3 9.5 3.8 8 0.8 10.7 6.1 351 6 351 165 0.7 0 0.9 0.7 11/08/2005 13:00:00 7.9 1.1 10.3 5.3 7.2 1.7 10.3 3 7.8 1.1 10.3 5.3 347 8 352 165 0.4 0 0.7 0.2 11/08/2005 13:10:00 9.6 1.1 11.8 7.2 9.4 1.5 11.8 4.2 9.4 1.1 11.8 6.5 343 6 342 165 0.2 0 0.2 0.2 11/08/2005 13:20:00 10.2 0.8 12.2 7.6 10.1 0.9 12.2 7.2 10.2 0.7 11.8 8 340 6 341 165 0.2 0 0.2 -0.1 11/08/2005 13:30:00 9.2 1.3 12.6 5.7 9.2 1.4 12.2 5.3 9.2 1.3 12.2 5.3 334 8 336 165 0.4 0 0.7 0.2 11/08/2005 13:40:00 9.8 1 12.6 7.2 9.8 1.1 12.2 5.3 9.6 1 12.6 6.5 341 6 331 165 0.4 0.1 0.7 0.2 11/08/2005 13:50:00 10.1 1 12.2 6.8 9.8 1.5 12.2 5.3 9.9 1 11.8 6.8 342 7 333 165 0.3 0 0.4 0.2 11/08/2005 14:00:00 10.1 1.1 13 7.6 9.8 1.4 13.3 5.3 10 1.1 13 7.2 342 6 338 165 0.2 0 0.2 0.2 11/08/2005 14:10:00 9.8 1 11.8 6.8 9.7 1.1 12.2 5.7 9.7 1 12.2 7.2 339 7 350 165 0.1 0 0.2 -0.1 11/08/2005 14:20:00 9.3 1.2 13 6.5 9 1.5 13.3 5.3 9.2 1.2 13 6.8 342 8 347 165 0.1 0 0.2 -0.1 11/08/2005 14:30:00 9.2 0.9 11.8 6.5 9.1 1 11.8 6.1 9.1 0.9 11.5 6.8 336 7 340 165 0.1 0 0.2 -0.1 11/08/2005 14:40:00 8.7 1.3 13 6.5 8.6 1.2 12.2 5.7 8.7 1.3 13 6.1 336 8 330 165 0.1 0 0.2 -0.1 11/08/2005 14:50:00 10 1.2 12.6 6.5 9.9 1.2 12.2 6.5 9.7 1.1 13 6.8 337 6 324 165 0 0 0.2 -0.1 11/08/2005 15:00:00 11.1 1 14.1 8.8 11 0.9 14.5 8.4 11 1 13.7 8.4 336 5 348 165 -0.1 0 -0.1 -0.3 11/08/2005 15:10:00 11 1.3 14.1 7.6 10.9 1.4 14.1 7.2 10.8 1.3 13.7 7.2 335 8 339 165 -0.1 0 -0.1 -0.3 11/08/2005 15:20:00 11.3 1.2 14.9 8 11.2 1.2 14.5 7.6 11.1 1.3 14.9 7.2 333 8 336 165 -0.2 0 -0.1 -0.5 11/08/2005 15:30:00 11.5 1 14.1 7.2 11.4 1 14.1 7.6 11.4 1.1 13.7 8 335 7 335 165 -0.2 0 -0.1 -0.3 11/08/2005 15:40:00 11.7 1.1 14.1 7.6 11.6 1.1 14.1 8 11.6 1 13.7 8.8 335 6 332 165 -0.3 0 -0.1 -0.3 11/08/2005 15:50:00 12.5 1.1 15.6 9.5 12.4 1.1 15.3 10.3 12.3 1.2 16.4 9.5 336 6 331 165 -0.3 0 -0.3 -0.5 11/08/2005 16:00:00 13 1.2 16.1 9.5 13 1.3 16.1 9.1 12.7 1.3 16.1 8.4 337 7 335 165 -0.3 0 -0.1 -0.5 11/08/2005 16:10:00 11.9 1.3 15.3 7.6 11.7 1.5 16.1 6.1 11.8 1.3 14.9 8.8 338 9 345 165 -0.3 0 -0.1 -0.5 11/08/2005 16:20:00 13.1 1.1 15.6 9.5 12.9 1 16.1 9.5 12.8 1.1 15.6 9.5 333 6 339 165 -0.3 0 -0.3 -0.5 11/08/2005 16:30:00 12.1 1.7 15.3 8.4 12 1.6 15.3 8 12 1.8 17.2 7.6 334 7 334 165 -0.4 0 -0.3 -0.5 11/08/2005 16:40:00 13.1 1.1 15.6 9.9 13 1.2 16.1 9.9 12.8 1.3 16.4 9.9 335 6 338 165 -0.3 0 -0.3 -0.5 11/08/2005 16:50:00 13 1.5 18.3 8.4 13 1.5 18.7 8 12.9 1.5 17.2 8.4 336 7 352 165 -0.3 0 -0.1 -0.5 11/08/2005 17:00:00 12.8 1.3 15.6 9.5 12.9 1.3 16.4 9.1 12.8 1.2 15.6 8.8 338 6 333 165 -0.3 0 -0.1 -0.5 11/08/2005 17:10:00 13 1.3 15.6 8.8 12.9 1.3 15.6 8.4 12.7 1.3 16.1 8.8 335 6 331 165 -0.3 0 -0.3 -0.5 11/08/2005 17:20:00 12.7 1.3 16.4 9.1 12.8 1.3 16.4 8.8 12.5 1.4 16.4 9.1 337 6 339 165 -0.3 0 -0.1 -0.8 11/08/2005 17:30:00 12.6 1.1 16.4 9.9 12.6 1.1 16.4 8.8 12.7 1.1 16.1 9.9 335 7 336 165 -0.3 0 -0.3 -0.5 11/08/2005 17:40:00 12.6 1.1 15.3 9.5 12.7 1.2 15.3 9.1 12.6 1.3 16.1 8.8 338 6 333 165 -0.3 0 -0.3 -0.8 11/08/2005 17:50:00 11.9 1.3 14.9 8 11.8 1.8 15.3 6.5 12 1.5 15.6 8 342 7 335 165 -0.3 0 -0.3 -0.5 11/08/2005 18:00:00 13.3 1 15.6 10.3 13.4 1.1 16.1 9.9 13.3 1.2 17.2 9.9 340 5 344 165 -0.3 0 -0.3 -0.5 11/08/2005 18:10:00 13.7 1 16.8 11.1 13.8 1 16.8 11.1 13.8 1.1 16.4 10.7 336 4 335 165 -0.3 0 -0.1 -0.5 11/08/2005 18:20:00 13 1.3 17.6 7.6 12.9 1.5 17.6 7.2 13.2 1.5 16.8 6.8 336 8 334 165 -0.2 0 -0.1 -0.5 11/08/2005 18:30:00 13.7 1 16.1 11.1 13.9 1 16.4 11.1 13.6 1.1 16.1 10.3 340 4 343 165 -0.2 0 -0.1 -0.3 11/08/2005 18:40:00 12.8 1.6 16.4 8.4 12.9 1.7 16.8 8.4 12.8 1.7 17.2 9.5 341 7 344 165 -0.2 0 0.2 -0.5 11/08/2005 18:50:00 12.4 1 16.1 9.1 12.6 1.1 15.6 9.1 12.5 1.1 16.1 9.1 338 7 338 165 -0.1 0 0.2 -0.3 11/08/2005 19:00:00 13.1 1 16.4 9.9 13.3 1.1 17.2 9.5 13.3 1.1 16.1 10.3 341 6 340 165 -0.3 0 -0.1 -0.5 11/08/2005 19:10:00 13.1 1.3 16.8 9.5 13.3 1.3 16.8 9.5 13.3 1.3 16.8 10.3 338 5 329 165 -0.3 0 -0.1 -0.5 11/08/2005 19:20:00 12.5 1 16.1 9.5 12.6 1 16.1 9.9 12.5 1.1 15.6 9.5 339 6 352 165 -0.3 0 -0.3 -0.5 11/08/2005 19:30:00 12.6 1 15.6 9.9 12.7 1 15.3 9.9 12.7 1.1 15.6 9.9 337 5 336 165 -0.3 0 -0.1 -0.5 11/08/2005 19:40:00 12.1 1.1 14.9 9.5 12.1 1.1 14.9 6.8 12.1 1.1 15.6 9.1 338 6 348 165 -0.3 0 -0.1 -0.3 11/08/2005 19:50:00 12.8 1.1 16.1 9.9 12.9 1.2 15.6 9.9 12.7 1.2 16.4 9.9 338 6 335 165 -0.3 0 -0.1 -0.5 11/08/2005 20:00:00 11.6 1.3 16.1 8 11.4 1.9 15.6 4.6 11.5 1.5 15.6 7.2 340 9 338 165 0 0 0.2 -0.3 11/08/2005 20:10:00 11.2 1 14.1 9.1 11.3 1.2 14.5 7.6 11.3 1.2 14.5 8.4 340 8 341 165 -0.1 0 -0.1 -0.3 11/08/2005 20:20:00 10 1.2 13 7.2 10 1.3 13 6.8 10 1.3 13.3 7.2 339 8 327 165 -0.1 0 0.2 -0.3 11/08/2005 20:30:00 9.8 0.9 13.7 8 9.8 0.9 13.7 7.6 9.8 0.8 13 8 333 9 330 165 -0.1 0 0.2 -0.3 11/08/2005 20:40:00 9.4 0.9 11.8 5.7 9 1.2 12.2 5.3 9.5 1 12.6 7.6 341 10 346 165 -0.2 0 -0.1 -0.5 11/08/2005 20:50:00 9.1 1 12.2 5.7 8.3 1.7 11.8 4.2 9.2 1 12.6 5.3 345 10 334 165 -0.3 0 -0.1 -0.5 11/08/2005 21:00:00 10.6 1 13.3 8 10.5 1.5 13.3 4.9 10.7 1.1 13.3 8 342 7 334 165 -0.3 0 -0.1 -0.5 11/08/2005 21:10:00 10.2 1.1 13.3 7.6 9.7 1.7 13.7 4.6 10.4 1.1 14.1 8.4 345 8 341 165 -0.3 0 -0.1 -0.5 11/08/2005 21:20:00 9.9 1.2 13.3 6.8 9.8 1.4 14.1 6.1 10.1 1.2 13 7.6 340 8 346 165 -0.3 0 -0.1 -0.5 11/08/2005 21:30:00 10.2 1.1 13 6.8 10.2 1.3 13.3 4.2 10.4 1 13.3 7.2 338 10 337 165 -0.2 0 -0.1 -0.3 11/08/2005 21:40:00 9.4 1 11.5 7.2 9 1.4 11.8 4.6 9.6 1 12.6 6.5 341 11 353 165 -0.2 0 -0.1 -0.3 11/08/2005 21:50:00 9.5 1 13.3 7.2 9.4 1.2 13.3 5.7 9.6 1 13.3 6.8 338 9 330 165 -0.3 0 -0.1 -0.5 11/08/2005 22:00:00 9.2 1 11.8 6.8 8.7 1.5 11.5 4.2 9.2 1 11.8 6.8 337 11 333 165 -0.2 0 -0.1 -0.3 11/08/2005 22:10:00 9 1.3 12.6 6.1 8.9 1.5 13 4.6 9.2 1.2 13 6.1 338 8 340 165 -0.3 0 -0.1 -0.5 11/08/2005 22:20:00 8.2 1.3 11.5 6.1 7.5 1.6 11.5 3.8 8.6 1.3 12.2 6.5 344 12 6 165 -0.4 0 -0.3 -0.5 11/08/2005 22:30:00 7.8 1.1 10.7 4.6 7.3 1.3 10.7 3.8 7.9 1.1 10.7 5.7 342 10 332 165 -0.4 0 -0.3 -0.8 11/08/2005 22:40:00 8.4 1.5 12.6 5.7 7.8 1.7 12.2 4.2 8.5 1.5 12.2 5.7 344 9 341 165 -0.5 0 -0.3 -0.8 11/08/2005 22:50:00 8.8 1.2 13 6.5 8.6 1.6 13 4.6 8.7 1.3 13 6.5 340 9 342 165 -0.4 0 -0.3 -0.8 11/08/2005 23:00:00 8.9 1.1 11.8 6.5 8.1 1.7 11.8 4.2 9 1 12.6 6.1 344 12 350 165 -0.6 0 -0.5 -0.8 11/08/2005 23:10:00 9 1 11.8 6.1 8.3 1.5 11.8 4.2 8.9 1.1 12.6 6.1 344 11 339 165 -0.8 0 -0.5 -0.8 11/08/2005 23:20:00 8.9 1.4 12.6 6.1 8.6 1.7 13 4.9 8.9 1.2 12.6 6.8 341 9 341 165 -0.7 0 -0.5 -1 11/08/2005 23:30:00 9.5 1.5 13.3 5.7 9.5 1.7 13.3 5.3 9.7 1.5 13.7 6.1 339 8 333 165 -0.6 0 -0.5 -0.8 11/08/2005 23:40:00 9.4 1.5 14.1 6.1 9.4 1.6 13.7 4.6 9.6 1.5 14.1 6.1 337 9 338 165 -0.6 0 -0.5 -0.8 11/08/2005 23:50:00 9.9 1.3 13.3 6.8 9.7 1.5 13.3 5.3 10 1.3 14.1 7.2 341 8 336 165 -0.6 0 -0.5 -0.8 11/09/2005 00:00:00 9.6 1.4 13.7 6.5 9.6 1.5 14.1 6.5 9.7 1.4 14.5 6.5 334 8 340 165 -0.6 0 -0.5 -0.8 11/09/2005 00:10:00 9 1.1 12.6 6.5 9 1.2 13.3 5.7 9 1.2 12.2 6.5 337 8 341 165 -0.7 0 -0.5 -0.8 11/09/2005 00:20:00 9.1 1 11.8 7.2 8.8 1.5 12.6 4.6 9.1 1 11.5 6.8 340 10 345 165 -0.8 0 -0.5 -1 11/09/2005 00:30:00 10 1.1 12.2 7.2 9.9 1.1 12.2 7.2 9.9 1.1 12.2 7.2 336 9 344 165 -0.8 0 -0.8 -1 11/09/2005 00:40:00 9.7 1.1 12.6 6.8 9.6 1.2 13 6.1 9.8 1 12.6 7.2 337 9 338 165 -0.8 0 -0.5 -0.8 11/09/2005 00:50:00 9.8 1.1 12.6 7.6 9.7 1.5 13 4.6 9.9 1.1 13 7.6 341 8 339 165 -0.8 0 -0.8 -1 11/09/2005 01:00:00 10.4 1 13 7.6 10.4 1.2 13 6.1 10.5 1 13 8 341 8 339 165 -0.6 0 -0.5 -1 11/09/2005 01:10:00 10.7 1 13.3 7.2 10.8 1.1 13.3 7.2 11 1.1 14.1 7.6 341 7 353 165 -0.6 0 -0.5 -0.8 11/09/2005 01:20:00 11.2 0.9 13.7 8.8 11.2 1.1 13.7 8.4 11.4 1 13.7 8.4 343 6 344 165 -0.7 0 -0.5 -1 11/09/2005 01:30:00 11.5 1 14.9 8.8 11.6 1.2 14.9 7.2 11.8 1.1 15.3 8.8 340 7 335 165 -0.8 0 -0.5 -1 11/09/2005 01:40:00 11.4 1.1 14.5 8.8 11.3 1.3 14.9 6.1 11.5 1.1 14.9 8.8 337 9 336 165 -0.6 0 -0.5 -0.8 11/09/2005 01:50:00 11.1 1.2 14.9 8.8 11.1 1.6 15.3 6.5 11.2 1.3 15.3 8.8 340 8 348 165 -0.6 0 -0.5 -0.8 11/09/2005 02:00:00 12.8 1.1 16.1 9.1 13 1.3 16.4 9.5 12.9 1.2 16.1 9.5 340 5 347 165 -0.6 0 -0.5 -0.8 11/09/2005 02:10:00 13.3 1.1 15.6 10.3 13.4 1.2 16.1 8.8 13.3 1.3 16.1 9.5 337 6 333 165 -0.6 0 -0.5 -0.8 11/09/2005 02:20:00 13 1.1 16.1 10.3 12.9 1.4 16.4 7.6 13 1.2 16.4 10.7 342 7 348 165 -0.7 0 -0.5 -1 11/09/2005 02:30:00 11.8 1.3 15.3 8.4 11.9 1.7 15.6 6.5 12.3 1.5 16.4 9.5 340 8 341 165 -0.6 0 -0.5 -0.8 11/09/2005 02:40:00 11.2 1.4 14.9 7.2 10.8 1.8 14.9 6.5 11.4 1.3 14.1 7.2 342 9 338 165 -0.6 0 -0.5 -0.8 11/09/2005 02:50:00 11 1.7 15.3 6.1 11 1.9 15.3 6.1 11.3 1.7 15.3 7.2 335 9 339 165 -0.5 0 -0.3 -0.8 11/09/2005 03:00:00 12.2 1.5 16.4 9.1 12.2 1.5 17.2 8.8 12.2 1.5 16.4 8.8 336 7 351 165 -0.6 0 -0.5 -0.8 11/09/2005 03:10:00 13.3 1.5 17.9 9.5 13.4 1.5 17.9 9.1 13.3 1.5 17.6 9.5 337 7 339 165 -0.6 0 -0.5 -0.8 11/09/2005 03:20:00 12.9 1.4 16.4 9.1 12.9 1.5 16.4 8.8 12.8 1.5 16.1 9.1 334 7 339 165 -0.6 0 -0.5 -0.8 11/09/2005 03:30:00 12.1 1.7 17.2 7.6 12 1.8 17.2 6.8 12.1 1.7 17.6 7.2 334 10 341 165 -0.6 0 -0.5 -0.8 11/09/2005 03:40:00 11.7 1.6 15.3 8.8 11.6 1.7 15.3 6.1 11.6 1.6 15.6 7.6 334 9 336 165 -0.6 0 -0.5 -0.8 11/09/2005 03:50:00 11.9 1.1 15.3 8.4 11.7 1.3 15.3 7.6 12 1.2 14.9 9.1 337 11 339 165 -0.7 0 -0.5 -0.8 11/09/2005 04:00:00 12 1.2 16.1 8.4 12 1.2 16.1 8.4 12 1.3 16.4 8.4 329 9 348 165 -0.7 0 -0.5 -0.8 11/09/2005 04:10:00 13.6 1.5 17.2 9.9 13.5 1.5 16.8 9.5 13.6 1.5 17.2 9.5 331 7 340 165 -0.5 0 -0.3 -0.8 11/09/2005 04:20:00 12.2 1.5 15.6 8.8 12.1 1.5 15.6 7.2 11.8 1.5 16.1 8 331 9 338 165 -0.3 0 -0.3 -0.5 11/09/2005 04:30:00 13.1 1.7 17.6 9.1 12.9 1.9 17.2 6.8 13 1.8 17.6 8.8 331 11 338 165 -0.5 0 -0.3 -0.8 11/09/2005 04:40:00 13.1 1.8 17.6 8.8 13.1 1.8 17.2 8.8 13 1.8 17.6 9.1 333 8 334 165 -0.6 0 -0.5 -0.8 11/09/2005 04:50:00 14 1.6 19.1 10.3 13.9 1.7 19.1 9.9 13.8 1.7 18.3 9.9 332 9 338 165 -0.5 0 -0.3 -0.8 11/09/2005 05:00:00 14.2 1.6 18.7 9.5 13.9 1.7 18.7 9.5 14 1.6 19.1 9.5 330 10 334 165 -0.5 0 -0.3 -0.5 11/09/2005 05:10:00 14.2 1.7 19.1 9.5 14.1 1.8 18.7 9.1 14.1 1.8 18.3 9.9 332 8 330 165 -0.4 0 -0.3 -0.8 11/09/2005 05:20:00 14.2 1.6 17.9 10.3 14 1.7 17.9 8.8 14.1 1.9 18.7 9.5 334 9 346 165 -0.3 0 -0.1 -0.5 11/09/2005 05:30:00 14.1 1.6 18.7 10.3 14 1.7 18.3 10.3 14 1.7 18.3 10.7 333 10 332 165 -0.3 0 -0.1 -0.5 11/09/2005 05:40:00 14.3 2 18.7 10.3 14.2 2 19.1 9.9 14 2.2 19.1 9.9 330 9 332 165 -0.3 0 -0.1 -0.5 11/09/2005 05:50:00 14.6 2.1 19.9 9.9 14.6 2.2 20.2 9.9 14.4 2.5 19.9 8.8 331 10 341 165 -0.1 0 0.2 -0.5 11/09/2005 06:00:00 14.6 2 19.5 9.5 14.4 2.1 19.5 9.1 14.6 2.2 19.9 8.4 337 10 339 165 -0.1 0 0.2 -0.3 11/09/2005 06:10:00 14.2 1.7 18.3 9.9 14 2 18.3 7.6 14 1.7 17.9 8.8 337 11 329 165 -0.1 0 0.2 -0.1 11/09/2005 06:20:00 15 1.6 19.5 10.3 15 1.7 19.1 9.1 15.1 1.7 19.5 9.1 336 9 339 165 0 0 0.2 -0.3 11/09/2005 06:30:00 15.6 1.9 21 11.5 15.6 1.9 21 11.1 15.5 2 21.4 11.1 335 8 332 165 0.1 0.1 0.2 -0.1 11/09/2005 06:40:00 14.5 2.1 19.1 9.5 14.5 2.2 19.1 9.5 14.6 2.2 19.9 9.9 333 9 340 165 0.1 0 0.2 -0.1 11/09/2005 06:50:00 14.7 1.6 19.5 9.9 14.7 1.7 19.5 7.6 14.6 1.7 19.5 9.9 334 9 333 165 0.1 0 0.2 -0.1 11/09/2005 07:00:00 15.3 2 19.5 10.3 15.2 2.3 19.9 9.1 15.4 2.1 19.1 9.5 337 9 343 165 0.1 0 0.2 -0.1 11/09/2005 07:10:00 15.7 1.7 21.4 12.2 15.6 2 19.9 8.8 16.1 1.8 21.8 11.5 334 10 353 165 0 0 0.2 -0.1 11/09/2005 07:20:00 15.9 2.1 20.2 11.1 15.9 2.1 21 10.7 15.9 2.2 21 9.9 332 9 343 165 -0.1 0 0.2 -0.1 11/09/2005 07:30:00 16.2 1.7 20.2 11.8 16.1 1.7 20.6 9.1 16.2 1.7 21 11.8 332 8 328 165 -0.1 0 0.2 -0.1 11/09/2005 07:40:00 16.3 2.4 21.8 11.1 16.2 2.4 21.4 11.1 16 2.5 22.6 11.1 334 8 337 165 -0.1 0 0.2 -0.3 11/09/2005 07:50:00 14.9 2.2 21.8 9.1 14.8 2.2 21.8 9.1 14.7 2.4 21.8 9.5 334 10 341 165 -0.3 0 -0.1 -0.3 11/09/2005 08:00:00 14.2 2.2 21.8 8.4 14.2 2.2 21.4 8.4 14 2.2 21.8 9.1 333 9 332 165 -0.3 0 -0.1 -0.3 11/09/2005 08:10:00 13.3 1.7 19.5 9.9 13.2 1.9 20.6 9.1 13.2 1.9 18.7 9.1 335 9 344 165 -0.3 0 -0.1 -0.3 11/09/2005 08:20:00 13.8 1.7 18.7 9.9 13.8 1.7 18.7 9.5 13.7 1.8 18.3 10.7 331 8 329 165 -0.2 0 -0.1 -0.3 11/09/2005 08:30:00 13.8 1.8 17.6 8 13.8 1.8 18.3 8.4 13.6 1.7 18.3 8.8 331 10 343 165 -0.3 0 -0.1 -0.3 11/09/2005 08:40:00 13.8 1.5 18.3 9.5 13.9 1.6 17.9 9.9 13.8 1.5 17.6 9.9 329 9 327 165 -0.3 0 -0.1 -0.3 11/09/2005 08:50:00 14.2 1.5 18.7 10.7 14.2 1.6 19.1 10.7 14.3 1.6 18.3 9.1 335 10 343 165 -0.3 0 -0.3 -0.3 11/09/2005 09:00:00 13.9 1.6 18.3 9.9 13.8 1.7 18.3 9.5 13.8 1.8 17.6 9.1 335 9 338 165 -0.3 0 -0.1 -0.5 11/09/2005 09:10:00 13.9 2.1 19.9 8.4 13.8 2.1 19.5 8.8 13.6 2.2 19.9 8.8 332 9 332 165 -0.3 0 -0.1 -0.3 11/09/2005 09:20:00 14.6 1.5 20.2 10.7 14.6 1.5 19.9 11.1 14.5 1.6 19.1 9.9 332 9 333 165 -0.3 0 -0.1 -0.5 11/09/2005 09:30:00 14.5 1.7 17.9 9.9 14.5 1.7 18.3 10.7 14.6 1.8 19.9 9.5 329 9 338 165 -0.3 0 -0.1 -0.3 11/09/2005 09:40:00 15.6 1.9 21 10.7 15.4 2.1 21.4 7.6 15.7 1.9 22.6 11.8 332 9 337 165 -0.3 0 -0.3 -0.5 11/09/2005 09:50:00 13.6 2 19.1 9.5 13.6 2 19.1 9.1 13.6 2 19.1 9.5 333 9 326 165 -0.3 0 -0.3 -0.5 11/09/2005 10:00:00 14.8 2 20.6 11.1 14.7 2 20.2 10.7 14.6 2 19.9 10.3 330 9 318 165 -0.3 0 -0.3 -0.5 11/09/2005 10:10:00 14.1 2 19.9 9.9 14 2 19.9 9.5 13.8 2 19.1 8.8 332 9 328 165 -0.3 0 -0.1 -0.5 11/09/2005 10:20:00 14.1 1.9 19.1 9.5 14.1 1.8 19.5 9.5 14.1 1.9 18.7 9.5 334 10 335 165 -0.3 0 -0.1 -0.3 11/09/2005 10:30:00 15.3 2.1 22.1 8 15.2 2.3 21.4 8 15.2 2.2 21.8 7.6 332 10 333 165 -0.2 0 -0.1 -0.3 11/09/2005 10:40:00 15.5 2.2 19.9 8.8 15.4 2.2 19.5 8.4 15.2 2.3 21 8.4 335 9 339 165 0 0 0.2 -0.1 11/09/2005 10:50:00 15.1 1.6 19.9 10.7 14.8 1.7 19.9 8.4 14.9 1.8 21 9.5 334 9 337 165 0.1 0 0.2 -0.1 11/09/2005 11:00:00 15.9 1.7 21.8 11.5 15.9 1.7 21 11.1 15.8 1.8 21.4 11.1 331 8 326 165 0.2 0 0.2 -0.1 11/09/2005 11:10:00 14.7 2.2 21 9.1 14.6 2.2 20.6 8.8 14.8 2.2 20.6 8.8 334 11 323 165 0.1 0 0.2 -0.1 11/09/2005 11:20:00 15.8 2.2 21.4 11.5 15.7 2.2 21.4 10.7 15.6 2.3 22.1 10.7 334 9 338 165 0.2 0 0.4 -0.1 11/09/2005 11:30:00 15.8 1.8 21 11.5 15.7 2 21.8 10.7 15.7 2.1 21.4 10.7 334 10 337 165 0.4 0 0.7 0.2 11/09/2005 11:40:00 16.7 1.8 21.4 11.8 16.6 2 21.8 11.1 16.8 2.1 21 10.7 336 9 344 165 0.4 0 0.7 0.2 11/09/2005 11:50:00 17.7 2.1 23.3 11.8 17.6 2.3 23.7 10.3 18 2.3 24.4 12.2 336 8 343 165 0.2 0 0.2 0.2 11/09/2005 12:00:00 17 2.5 24 11.8 16.9 2.6 24 10.7 17.1 2.6 23.7 11.5 336 9 346 165 0.3 0 0.7 0.2 11/09/2005 12:10:00 18.3 1.8 25.2 11.1 18.3 2.1 25.2 9.1 18.5 1.8 25.6 13 337 9 337 165 0.4 0.1 0.7 0.2 11/09/2005 12:20:00 17.2 2.2 23.3 9.9 17.1 2.3 23.3 9.9 17.3 2.3 23.3 9.9 336 9 333 165 0.3 0 0.7 0.2 11/09/2005 12:30:00 17.1 2.2 22.6 11.8 16.7 2.4 22.6 9.9 17.3 2.3 22.6 11.5 341 10 338 165 0.5 0 0.7 0.2 11/09/2005 12:40:00 16.9 2.1 22.1 11.8 16.6 2.3 22.6 9.5 16.8 2.2 22.6 10.3 340 9 348 165 0.3 0 0.7 0.2 11/09/2005 12:50:00 17.1 2.7 24 10.3 16.6 2.6 24.4 9.5 17.1 2.6 24 10.7 339 10 351 165 0.1 0 0.2 -0.1 11/09/2005 13:00:00 18.7 2.4 23.7 9.9 18.5 2.7 24.8 8.8 18.8 2.5 24.4 10.7 341 8 338 165 -0.1 0 0.2 -0.1 11/09/2005 13:10:00 18.9 2.3 28.3 12.6 18.9 2.3 27.9 11.8 19 2.5 26 11.1 337 8 318 165 -0.1 0 0.2 -0.3 11/09/2005 13:20:00 18.1 2.4 25.2 9.1 17.8 2.7 25.6 6.5 18.3 2.6 25.2 11.1 341 9 339 165 -0.1 0 0.2 -0.3 11/09/2005 13:30:00 18.4 2.7 26 9.9 18 2.6 24 10.3 18.2 2.8 26 10.3 337 9 355 165 -0.2 0 -0.1 -0.3 11/09/2005 13:40:00 19 2.4 24.4 13 18.9 2.4 24.8 12.2 18.9 2.4 24.8 13.3 337 9 344 165 -0.2 0 -0.1 -0.5 11/09/2005 13:50:00 18.1 2.3 23.3 11.1 17.6 2.7 22.6 9.9 17.8 2.6 22.9 10.3 340 11 0 165 -0.3 0 -0.1 -0.3 11/09/2005 14:00:00 18.4 2.8 26 11.1 18.3 2.8 24.8 11.1 18 3.1 26.3 9.5 336 10 349 165 -0.2 0 -0.1 -0.3 11/09/2005 14:10:00 18.1 2.6 24.8 11.8 18.1 2.6 26.3 12.6 18.2 2.6 25.2 11.8 337 10 349 165 -0.3 0 -0.1 -0.3 11/09/2005 14:20:00 17.5 2.8 24 9.5 17.1 2.8 24 9.1 17.3 2.9 24 9.9 339 10 326 165 -0.2 0 -0.1 -0.3 11/09/2005 14:30:00 17.6 2.4 24 10.3 17 2.6 24 10.3 17.4 2.6 24.4 10.7 343 9 347 165 -0.3 0 -0.1 -0.3 11/09/2005 14:40:00 20.3 2.5 27.1 13.7 19.8 2.8 27.9 11.5 20.2 2.2 25.6 14.1 338 10 345 165 -0.3 0 -0.1 -0.3 11/09/2005 14:50:00 20.6 2.3 29.4 14.9 20.2 2.4 26 13.3 20.4 2.5 27.1 14.5 337 9 358 165 -0.4 0 -0.3 -0.5 11/09/2005 15:00:00 19.9 2.5 27.9 13.7 19.5 2.6 27.1 13.3 19.6 2.7 27.1 13.3 337 11 355 165 -0.4 0 -0.3 -0.5 11/09/2005 15:10:00 19.2 2.6 27.1 12.6 18.8 2.7 25.2 11.5 19 2.7 25.2 11.8 339 9 347 165 -0.3 0 -0.1 -0.5 11/09/2005 15:20:00 18.3 2.5 24 11.5 18 2.7 25.2 11.1 18.1 2.6 24 11.5 339 11 333 165 -0.3 0 -0.1 -0.5 11/09/2005 15:30:00 19.4 2.9 26 12.6 19 3.1 27.5 11.5 19.1 3.1 26 11.5 336 10 343 165 -0.3 0 -0.3 -0.5 11/09/2005 15:40:00 19.1 2.7 27.1 12.2 18.6 2.9 26.3 9.5 19 2.7 27.1 11.5 340 10 350 165 -0.5 0 -0.3 -0.5 11/09/2005 15:50:00 18 2.8 26.8 11.5 17.6 3.1 27.1 11.1 17.5 3.1 26.8 11.1 340 11 342 165 -0.5 0 -0.3 -0.5 11/09/2005 16:00:00 18.4 2.5 24.8 11.5 17.9 2.6 24.8 10.3 18.5 2.7 27.9 11.8 337 12 334 165 -0.3 0 -0.1 -0.5 11/09/2005 16:10:00 16.9 2.1 22.1 11.8 16.5 2 23.3 11.5 16.3 2.2 23.3 11.1 336 11 358 165 -0.3 0 -0.1 -0.5 11/09/2005 16:20:00 17.5 2.4 24 12.2 16.8 2.4 23.3 8.8 17.1 2.5 24 11.8 338 12 358 165 -0.3 0 -0.1 -0.5 11/09/2005 16:30:00 18 1.9 22.6 13 17.7 2 22.9 11.8 17.4 1.9 22.1 12.2 336 11 349 165 -0.3 0 -0.1 -0.5 11/09/2005 16:40:00 19.9 2.7 26.8 13.7 19.4 2.8 26.3 10.3 19.8 2.9 26 12.2 341 11 346 165 -0.3 0 -0.1 -0.5 11/09/2005 16:50:00 18.6 2.5 24.4 12.6 18.2 2.6 24.4 12.2 18 2.7 25.6 9.9 338 12 350 165 -0.5 0 -0.3 -0.5 11/09/2005 17:00:00 18.9 2.6 25.2 13 18.1 2.7 24.4 11.1 18.4 2.6 25.6 12.2 341 11 353 165 -0.6 0 -0.5 -0.8 11/09/2005 17:10:00 18.5 2.1 23.7 14.1 18.1 2.3 23.3 11.5 18.1 2.2 24 13.3 336 11 337 165 -0.6 0 -0.5 -0.5 11/09/2005 17:20:00 18.2 2.5 24.4 12.6 17.8 2.6 24 11.5 17.7 2.4 23.3 11.1 336 11 338 165 -0.4 0 -0.3 -0.5 11/09/2005 17:30:00 16.2 2.5 24 10.3 15.7 2.4 22.9 10.3 15.4 2.6 22.6 8.4 334 13 351 165 -0.5 0 -0.5 -0.5 11/09/2005 17:40:00 17.7 2.5 24 11.8 17.2 2.6 24.4 11.8 16.8 2.6 26 11.1 338 12 353 165 -0.5 0 -0.3 -0.5 11/09/2005 17:50:00 14.9 1.9 19.9 9.9 14.7 2 19.9 9.1 14.4 1.9 18.7 9.1 334 12 317 165 -0.6 0 -0.5 -0.8 11/09/2005 18:00:00 15.4 2.3 22.9 11.1 15.2 2.4 23.3 9.9 14.6 2.3 21.8 9.5 328 13 344 165 -0.5 0 -0.5 -0.5 11/09/2005 18:10:00 16 2 22.9 10.7 15.9 2.1 24 10.7 15.2 2.2 23.7 10.3 332 11 347 165 -0.4 0 -0.3 -0.5 11/09/2005 18:20:00 18 2.6 26.3 11.8 17.6 2.6 24.4 11.5 18 3.1 24.8 10.7 338 12 352 165 -0.5 0 -0.3 -0.8 11/09/2005 18:30:00 18.7 3.2 26.3 11.5 18.2 3.1 27.5 11.1 18.1 3.3 26.8 11.1 337 12 349 165 -0.5 0 -0.3 -0.5 11/09/2005 18:40:00 17.9 2.8 26 12.2 17 2.5 25.6 11.1 17.1 2.9 26.3 10.3 339 14 351 165 -0.6 0 -0.5 -0.5 11/09/2005 18:50:00 15.2 1.8 20.6 10.7 14.8 1.7 19.5 11.1 14.4 1.7 19.1 10.3 334 13 343 165 -0.5 0 -0.5 -0.8 11/09/2005 19:00:00 15.9 2.2 22.9 10.3 15.6 2.1 21.4 10.3 14.7 2 19.9 9.9 329 13 353 165 -0.5 0 -0.3 -0.5 11/09/2005 19:10:00 16.5 1.8 22.6 11.8 16.4 1.9 22.1 11.8 16.1 1.8 20.6 11.1 334 13 2 165 -0.3 0 -0.3 -0.5 11/09/2005 19:20:00 18.7 2.2 24.4 13.3 17.2 2.3 23.7 9.9 17.8 2.6 24.8 11.1 348 7 353 165 -0.3 0 -0.1 -0.3 11/09/2005 19:30:00 17.8 3.1 26.8 9.5 17 2.7 27.5 9.9 17.4 3.2 27.9 11.5 339 11 343 165 -0.2 0 -0.1 -0.3 11/09/2005 19:40:00 15.9 1.9 21.8 11.8 15.7 1.8 22.6 11.5 14.9 2.1 20.6 9.9 329 15 352 165 -0.3 0 -0.1 -0.3 11/09/2005 19:50:00 18.2 2.5 24.4 10.3 17.5 2.3 23.7 11.1 17.5 2.5 24 9.5 340 12 347 165 -0.3 0 -0.1 -0.5 11/09/2005 20:00:00 20.9 2.7 28.7 13.7 20.4 2.9 29.1 12.6 21.1 2.9 28.7 14.1 343 9 350 165 -0.2 0 -0.1 -0.3 11/09/2005 20:10:00 17.8 2.3 24 12.6 17.2 2.5 25.2 11.8 17.4 2.6 24.4 11.8 337 14 348 165 -0.3 0 -0.1 -0.5 11/09/2005 20:20:00 16.9 2.3 23.3 11.5 16.6 2.4 24 11.1 16.2 2.3 22.6 11.5 336 11 344 165 -0.3 0 -0.1 -0.5 11/09/2005 20:30:00 18.2 2.4 27.1 12.6 17.7 2.6 27.5 11.1 18 2.5 25.2 10.3 337 11 341 165 -0.3 0 -0.3 -0.5 11/09/2005 20:40:00 19.6 2.9 27.1 12.2 19 2.9 26 12.2 19.4 3.1 26 12.2 337 11 358 165 -0.3 0 -0.1 -0.3 11/09/2005 20:50:00 18.3 2.6 25.6 11.8 17.8 2.8 26.3 10.7 17.7 2.7 26 11.1 335 13 340 165 -0.2 0 -0.1 -0.3 11/09/2005 21:00:00 15.7 2.1 25.6 9.9 15.5 2.2 26.8 10.3 14.6 2.2 20.2 9.5 324 15 303 165 -0.2 0 -0.1 -0.3 11/09/2005 21:10:00 18.1 2.2 23.3 11.5 17.8 2.3 22.9 11.5 17.6 2.4 24.4 10.3 335 11 333 165 -0.2 0 -0.1 -0.3 11/09/2005 21:20:00 18.9 2.5 26.8 12.2 18.5 2.6 26.3 12.6 18.4 2.9 26.3 9.1 336 10 327 165 -0.2 0 -0.1 -0.3 11/09/2005 21:30:00 17.4 2.5 27.5 11.1 17.3 2.6 25.6 11.8 16.8 2.6 27.1 11.8 332 13 339 165 -0.1 0 0.2 -0.3 11/09/2005 21:40:00 16.2 2.2 22.6 11.5 15.6 2.1 19.9 10.3 15.5 2.5 22.1 10.3 335 14 358 165 -0.1 0 -0.1 -0.3 11/09/2005 21:50:00 17.5 2.4 25.2 11.8 17.4 2.4 25.6 11.8 16.8 2.4 22.1 11.1 337 9 341 165 -0.2 0 -0.1 -0.3 11/09/2005 22:00:00 16 2.1 21.4 8.8 15.7 2.3 21.8 8.8 15.7 2.1 21 8.4 338 10 355 165 -0.2 0 -0.1 -0.3 11/09/2005 22:10:00 15.9 2.6 21.4 10.7 15.9 2.7 21.4 9.9 15.4 2.8 21.8 9.1 337 9 326 165 -0.2 0 -0.1 -0.3 11/09/2005 22:20:00 18.4 2.4 24 11.8 17.8 2.5 23.7 11.5 17.8 2.7 23.7 11.1 336 13 327 165 0 0 0.2 -0.1 11/09/2005 22:30:00 16.6 2.6 23.3 8.4 16.6 2.6 22.9 8.4 16 2.7 21.8 8 332 9 334 165 0 0 0.2 -0.1 11/09/2005 22:40:00 18.5 2.9 26 12.6 18.3 3.2 25.2 10.7 18.1 3.1 24.4 9.5 337 9 357 165 -0.1 0 0.2 -0.1 11/09/2005 22:50:00 19.1 2.3 24.4 12.6 19 2.5 25.6 12.2 18.8 2.6 25.6 11.5 335 9 346 165 -0.1 0 0.2 -0.1 11/09/2005 23:00:00 18.3 2.4 25.2 13.3 18.1 2.6 25.6 10.7 18.1 2.4 24.8 12.6 336 9 334 165 -0.1 0 0.2 -0.1 11/09/2005 23:10:00 18.3 2.3 24.4 13 18.1 2.6 25.2 11.5 18.2 2.4 24 11.5 338 10 344 165 -0.2 0 -0.1 -0.3 11/09/2005 23:20:00 18.9 2.3 24.4 13 18.8 2.3 24.4 12.2 18.4 2.4 24 11.8 334 7 341 165 -0.2 0 -0.1 -0.3 11/09/2005 23:30:00 19.6 2.5 26 12.2 19.5 2.5 26 12.2 19.3 2.6 26 11.1 337 7 345 165 0 0 0.2 -0.1 11/09/2005 23:40:00 18.5 2.3 22.9 13 18.4 2.3 23.3 12.2 18.1 2.4 24.8 12.2 335 10 336 165 -0.1 0 0.2 -0.1 11/09/2005 23:50:00 19.3 1.6 22.9 14.1 19.1 1.7 24 13.7 19.2 1.8 23.3 13.7 335 8 332 165 0.1 0 0.2 -0.1 11/10/2005 00:00:00 17.5 2 22.6 13 17.3 2.1 22.1 10.3 16.9 2.2 21.8 12.2 337 9 326 165 0.1 0 0.2 -0.3 11/10/2005 00:10:00 18.6 1.8 23.7 13.7 18.1 2 23.3 13.3 18.2 1.8 22.9 14.1 340 10 335 165 0.1 0 0.2 -0.1 11/10/2005 00:20:00 19.9 1.8 25.2 13.7 19.5 2.1 25.6 14.1 19.7 2.1 26 14.9 339 8 347 165 0.1 0 0.2 -0.1 11/10/2005 00:30:00 18 2.6 24.8 11.8 18 2.7 25.6 12.2 17.7 2.8 26 10.7 337 9 351 165 0.1 0 0.2 -0.1 11/10/2005 00:40:00 16.7 2.5 24 10.3 16.5 2.6 23.7 9.1 16.4 2.6 23.7 9.9 337 9 340 165 0.1 0 0.2 -0.1 11/10/2005 00:50:00 18.1 2.5 27.9 11.8 17.8 2.7 28.3 11.5 17.8 2.7 26.8 11.1 337 10 344 165 0.1 0 0.2 -0.1 11/10/2005 01:00:00 17.6 2.2 22.6 12.2 17.5 2.3 23.7 10.3 17.4 2.3 22.6 9.5 336 8 343 165 0.1 0 0.2 -0.1 11/10/2005 01:10:00 17.6 2.6 23.3 11.8 17.5 2.6 24 11.5 17.5 2.9 23.7 10.3 339 9 338 165 0.2 0 0.4 0.2 11/10/2005 01:20:00 18.5 2.6 24.8 11.1 18.5 2.7 26 11.1 18 2.7 24.8 10.3 340 7 341 165 0.2 0 0.4 0.2 11/10/2005 01:30:00 17.6 2.2 22.1 12.2 16.8 2.8 22.9 9.5 17.2 2.3 23.7 10.7 342 10 354 165 0.2 0 0.2 0.2 11/10/2005 01:40:00 18.6 2.5 24.4 11.5 18.5 2.7 24 11.1 18.6 2.6 24 10.7 339 9 351 165 0.2 0 0.4 0.2 11/10/2005 01:50:00 18.2 2.4 24.4 11.8 18 2.5 23.7 12.2 18.2 2.6 24.4 12.2 337 9 353 165 0.2 0 0.2 0.2 11/10/2005 02:00:00 17.9 2.2 24 12.2 17.7 2.3 24 11.8 17.8 2.4 25.2 11.5 338 9 339 165 0.3 0 0.4 0.2 11/10/2005 02:10:00 17.1 2.3 22.9 10.7 16.9 2.4 22.6 9.5 16.8 2.4 22.6 10.3 335 10 355 165 0.4 0 0.7 0.2 11/10/2005 02:20:00 17.7 2.3 23.3 11.5 17.6 2.4 24 11.1 17.3 2.4 23.3 10.7 337 8 350 165 0.2 0 0.4 0.2 11/10/2005 02:30:00 16.7 2.5 23.3 11.5 16.3 2.5 21.8 10.3 16.3 2.6 21.8 9.9 339 10 347 165 0.2 0 0.4 0.2 11/10/2005 02:40:00 12.8 1.7 17.2 8.4 12.6 1.7 17.2 8 12.1 1.7 16.1 7.6 327 12 330 165 0.2 0 0.4 -0.1 11/10/2005 02:50:00 12.9 1.7 16.8 6.8 12.8 1.7 16.4 7.2 12 1.7 15.6 7.2 321 13 302 165 -0.3 0 -0.1 -0.5 11/10/2005 03:00:00 13.5 2.1 19.1 8 13.4 2 19.9 8 12.3 2.3 18.3 6.8 317 14 343 165 -0.3 0 -0.1 -0.5 11/10/2005 03:10:00 13.9 1.7 17.6 8.4 13.8 1.7 17.6 9.5 11.8 1.8 16.1 6.8 307 9 294 165 -0.5 0 -0.3 -0.8 11/10/2005 03:20:00 13.3 2.2 17.9 6.8 13.2 2.1 17.9 6.5 11.6 2 16.1 6.1 311 12 308 165 -0.6 0 -0.5 -0.8 11/10/2005 03:30:00 13.3 1.7 17.6 9.1 13.1 1.7 17.6 8.4 12.3 1.8 16.8 8.4 321 15 329 165 -0.3 0.1 -0.1 -0.5 11/10/2005 03:40:00 13 1.8 17.6 8.4 12.9 1.7 17.2 8.4 11.6 1.8 16.1 6.8 312 11 300 165 -0.3 0 -0.3 -0.5 11/10/2005 03:50:00 14 1.6 17.6 8.4 13.8 1.5 17.2 8.4 12.7 1.6 16.4 8.8 315 11 321 165 -0.3 0 -0.1 -0.5 11/10/2005 04:00:00 14 2.2 19.5 8.8 13.9 2.1 19.5 8.8 12.1 2 19.1 6.8 308 11 304 165 -0.3 0 -0.1 -0.5 11/10/2005 04:10:00 15 1.8 18.7 9.1 14.8 1.7 18.7 9.5 12.2 1.9 17.2 7.6 303 8 298 165 -0.2 0 -0.1 -0.3 11/10/2005 04:20:00 16.4 2.4 21.4 9.9 16.3 2.3 21.8 10.3 13 2.1 19.9 8.4 300 6 298 165 -0.1 0 0.2 -0.3 11/10/2005 04:30:00 16.5 2.2 26 8.8 16.3 2.2 25.2 9.1 13.1 1.9 20.6 7.2 299 7 300 165 -0.2 0 0.2 -0.3 11/10/2005 04:40:00 16.9 1.9 21.4 12.2 16.8 1.8 20.6 11.8 13.4 1.9 19.5 9.1 298 6 297 165 -0.2 0 -0.1 -0.3 11/10/2005 04:50:00 17.3 2 21.8 12.2 17.1 2 21.4 11.8 13.6 1.9 19.9 9.5 296 6 293 165 -0.2 0 -0.1 -0.3 11/10/2005 05:00:00 17.2 1.8 22.9 12.2 17 1.8 22.1 12.2 13.5 2 21 8.4 297 6 292 165 -0.3 0 -0.1 -0.3 11/10/2005 05:10:00 16.7 1.6 20.6 11.8 16.4 1.6 19.9 11.8 12.9 1.8 17.9 7.2 296 5 295 165 -0.3 0 -0.1 -0.3 11/10/2005 05:20:00 16.9 2.1 22.1 10.7 16.7 2.1 21.4 11.1 13.2 2 17.6 7.6 296 7 295 165 -0.3 0 -0.1 -0.3 11/10/2005 05:30:00 18.5 2.4 23.7 11.1 18.3 2.3 23.7 11.5 14.2 2.2 20.6 8.4 299 6 293 165 -0.3 0 -0.1 -0.3 11/10/2005 05:40:00 18.7 2.1 23.3 12.6 18.6 2 22.9 12.2 14.5 1.7 19.1 9.5 299 6 297 165 -0.3 0 -0.1 -0.3 11/10/2005 05:50:00 19.7 1.8 24 13 19.6 1.8 23.7 13 14.9 1.7 19.5 9.5 297 5 298 165 -0.3 0 -0.3 -0.3 11/10/2005 06:00:00 19.2 2.2 26.8 12.2 19 2.1 26.8 11.8 14.5 2 22.9 9.1 297 5 309 165 -0.3 0 -0.1 -0.5 11/10/2005 06:10:00 19.1 2 27.1 14.1 18.9 1.9 27.1 13.7 14.6 2.1 21.8 10.7 300 6 304 165 -0.3 0 -0.1 -0.5 11/10/2005 06:20:00 18.7 2.4 24.8 10.3 18.6 2.3 24.4 9.9 14.7 2.4 22.6 8.4 300 7 310 165 -0.3 0 -0.1 -0.5 11/10/2005 06:30:00 19 2.3 23.7 11.5 18.9 2.2 23.3 11.8 14.5 2.2 19.9 9.1 299 5 302 165 -0.6 0 -0.5 -0.8 11/10/2005 06:40:00 19 1.9 23.3 12.2 18.9 1.9 22.9 11.8 14.3 1.7 19.9 9.9 299 5 298 165 -0.6 0 -0.5 -0.8 11/10/2005 06:50:00 19.6 1.7 24 14.1 19.6 1.7 23.7 14.1 14.7 1.6 19.5 9.5 299 4 305 165 -0.6 0 -0.5 -0.8 11/10/2005 07:00:00 20.4 1.5 24 15.6 20.4 1.5 23.7 16.1 15.9 1.7 20.2 11.8 301 4 300 165 -0.7 0 -0.5 -0.8 11/10/2005 07:10:00 20.3 1.9 25.2 14.9 20.2 1.9 24.8 14.5 15.8 1.6 22.1 11.8 302 5 302 165 -0.8 0 -0.5 -0.8 11/10/2005 07:20:00 20.3 1.6 23.7 15.6 20.2 1.7 23.7 14.9 16.7 1.7 22.6 12.6 304 5 307 165 -0.9 0 -0.5 -1 11/10/2005 07:30:00 18.9 1.8 24 14.5 18.8 1.8 24 14.1 16.1 2.1 21.4 11.5 305 5 305 165 -0.9 0 -0.8 -1.2 11/10/2005 07:40:00 18.7 1.8 22.6 13 18.5 1.8 22.6 13 15.8 1.9 21 9.1 306 6 307 165 -0.9 0 -0.8 -1 11/10/2005 07:50:00 19 2.1 24 14.1 18.8 2.1 24 13.3 15.9 2.3 22.1 10.7 305 5 310 165 -0.9 0 -0.8 -1.2 11/10/2005 08:00:00 17.9 2 21.8 11.5 17.8 2 21.4 11.5 15.3 2.1 21 9.9 306 7 310 165 -1 0 -1 -1.2 11/10/2005 08:10:00 17.9 2.2 22.6 12.2 17.8 2.2 22.1 11.5 14.6 1.9 21.4 9.5 302 7 279 165 -1.1 0 -1 -1.2 11/10/2005 08:20:00 17.4 1.9 21.8 11.5 17.3 1.9 21.8 11.8 13.8 1.9 19.9 9.1 300 7 292 165 -1.2 0 -1 -1.2 11/10/2005 08:30:00 17.4 1.7 21.8 11.8 17.3 1.7 21.4 11.8 14.4 2.1 20.2 9.9 303 8 305 165 -1.1 0 -1 -1.2 11/10/2005 08:40:00 19 2 23.7 12.6 18.9 2 23.7 13 16.5 2.1 22.6 10.7 307 6 307 165 -0.9 0 -0.8 -1.2 11/10/2005 08:50:00 18.1 2.3 24.4 11.5 18 2.3 24.4 11.5 15.7 2.6 21.8 10.7 306 6 301 165 -0.9 0 -0.8 -1 11/10/2005 09:00:00 17.8 2.2 23.3 12.6 17.7 2.2 22.9 11.5 15.2 2.1 20.6 9.1 305 7 307 165 -0.9 0 -0.8 -1.2 11/10/2005 09:10:00 18.6 2.2 22.6 11.5 18.5 2.2 22.6 11.5 16.2 2.3 21.4 11.1 307 6 304 165 -0.9 0 -0.8 -0.8 11/10/2005 09:20:00 18.2 1.9 22.6 13 18.1 1.9 22.1 12.2 14.8 2.2 19.9 9.9 304 6 304 165 -0.9 0 -0.8 -1.2 11/10/2005 09:30:00 17 1.8 20.6 12.6 16.9 1.8 20.6 11.8 13.9 1.7 18.3 8.4 302 7 292 165 -0.9 0 -0.8 -1.2 11/10/2005 09:40:00 16.2 2 21 10.7 16.1 2 20.6 11.1 13 2 17.9 8.8 303 8 305 165 -0.7 0 -0.5 -0.8 11/10/2005 09:50:00 16.8 1.7 21 11.5 16.7 1.7 20.6 11.1 13 1.7 18.7 7.6 299 7 307 165 -0.7 0.1 -0.5 -0.8 11/10/2005 10:00:00 18.7 1.6 22.6 13.3 18.7 1.6 22.9 13.3 14.9 1.7 20.6 10.7 295 6 302 165 -0.8 0 -0.8 -0.8 11/10/2005 10:10:00 20.2 1.1 22.9 16.4 20.3 1.1 22.9 15.6 15.5 1.7 22.9 12.6 294 4 290 165 -0.7 0 -0.5 -0.8 11/10/2005 10:20:00 19.9 1.4 23.3 16.8 20 1.4 23.7 17.2 15 1.7 21 11.1 295 4 295 165 -0.6 0 -0.5 -0.8 11/10/2005 10:30:00 20 1.5 23.7 16.4 20 1.5 23.7 16.1 14.5 1.5 19.5 11.1 297 4 290 165 -0.5 0 -0.5 -0.8 11/10/2005 10:40:00 19.4 1.5 22.9 14.9 19.4 1.5 23.3 14.9 14.6 1.7 20.2 11.5 296 5 292 165 -0.4 0 -0.3 -0.5 11/10/2005 10:50:00 18.2 1.7 22.6 13.3 18.2 1.7 22.9 13.3 13.9 2 19.9 8.4 296 6 298 165 -0.3 0 -0.1 -0.5 11/10/2005 11:00:00 18.2 1.9 23.3 12.6 18.2 2 22.9 12.2 13.9 1.9 19.9 8.4 298 6 294 165 -0.3 0 -0.1 -0.3 11/10/2005 11:10:00 16.9 1.8 21.4 11.8 16.9 1.8 21.8 11.1 12.5 1.8 18.7 8 300 6 296 165 -0.2 0 -0.1 -0.3 11/10/2005 11:20:00 17.7 1.7 21 11.5 17.7 1.7 21 11.5 13.3 1.8 20.2 9.1 302 5 301 165 -0.1 0 -0.1 -0.3 11/10/2005 11:30:00 16.5 1.7 20.6 12.2 16.4 1.8 20.2 12.2 13.5 1.9 18.3 9.1 306 6 302 165 -0.1 0 0.2 -0.1 11/10/2005 11:40:00 15.9 1.5 19.1 12.2 15.9 1.5 19.5 11.8 12.2 1.5 16.8 8.8 303 5 296 165 0.1 0 0.2 -0.1 11/10/2005 11:50:00 15.3 1.6 20.2 10.7 15.2 1.6 20.2 10.7 11.7 1.6 17.2 7.6 303 6 300 165 0.4 0 0.7 0.2 11/10/2005 12:00:00 15.3 2 19.5 9.9 15.2 2 19.5 10.3 11.4 1.7 15.3 7.2 302 5 303 165 0.5 0 0.7 0.2 11/10/2005 12:10:00 16.4 2.1 21 9.9 16.3 2.1 21 9.9 12.6 1.5 17.6 7.6 303 5 300 165 0.3 0.1 0.7 0.2 11/10/2005 12:20:00 15.7 1.7 19.5 10.7 15.7 1.7 19.5 10.7 12.4 1.8 16.4 8 304 6 299 165 0 0 0.2 -0.1 11/10/2005 12:30:00 16.1 1.4 19.5 11.8 16.1 1.5 19.5 11.8 12.7 1.7 17.2 8.8 304 6 303 165 -0.1 0 0.2 -0.1 11/10/2005 12:40:00 15.3 1.5 19.1 10.3 15.3 1.6 19.1 10.3 12 1.7 16.1 8.4 305 6 305 165 0.2 0 0.4 0.2 11/10/2005 12:50:00 13.9 1.7 17.2 9.1 13.8 1.7 17.2 9.1 10.6 1.3 14.5 6.5 301 6 300 165 0.5 0 0.7 0.2 11/10/2005 13:00:00 14.5 1.5 17.9 9.1 14.4 1.5 17.9 9.1 10.7 1.3 14.5 6.5 300 5 298 165 0.5 0 0.7 0.4 11/10/2005 13:10:00 14.4 1.5 17.9 10.3 14.4 1.5 17.6 9.9 10.7 1.4 14.9 6.8 299 6 298 165 0.6 0 0.7 0.7 11/10/2005 13:20:00 13.6 2 18.7 8.4 13.6 2 18.3 8.8 11.1 1.8 17.2 6.8 295 8 295 165 0.6 0 0.7 0.4 11/10/2005 13:30:00 14.5 1.8 18.7 10.3 14.4 1.9 19.1 10.7 11.2 1.7 16.4 7.2 298 7 294 165 0.5 0 0.7 0.4 11/10/2005 13:40:00 14.8 1.5 17.9 9.9 14.8 1.5 17.9 9.9 11 1.5 16.1 6.8 298 6 298 165 0.2 0 0.7 -0.1 11/10/2005 13:50:00 15.9 1.1 18.7 12.6 15.9 1.2 18.7 12.6 11.2 1.3 15.3 8.4 300 4 298 165 0 0 0.2 -0.1 11/10/2005 14:00:00 15.3 1.4 19.1 11.8 15.2 1.4 18.7 11.8 11.6 1.4 16.4 8.8 303 6 304 165 -0.1 0 0.2 -0.3 11/10/2005 14:10:00 15 1.7 17.9 9.9 15 1.7 17.6 9.5 11.4 1.5 15.3 7.6 305 6 301 165 0 0 0.2 -0.3 11/10/2005 14:20:00 14.5 1.5 17.6 9.1 14.4 1.6 17.6 9.5 10.8 1.4 14.5 6.8 304 5 302 165 0.3 0 0.7 -0.1 11/10/2005 14:30:00 12.4 1.4 15.6 8.4 12.4 1.5 15.3 8.4 9.3 1.2 14.5 6.5 302 6 304 165 0.4 0 0.7 0.2 11/10/2005 14:40:00 13 1.2 16.1 9.5 12.9 1.2 15.6 9.1 10 1.3 13.7 6.8 299 7 302 165 0.2 0 0.4 0.2 11/10/2005 14:50:00 12.1 1.5 15.6 8.4 12 1.4 15.3 7.6 9.5 1.2 13 6.5 303 7 297 165 0.4 0 0.7 0.2 11/10/2005 15:00:00 13.7 1.5 17.9 9.5 13.7 1.5 17.9 9.1 10.5 1.7 15.3 6.8 300 6 301 165 0.4 0.1 0.7 0.2 11/10/2005 15:10:00 13.6 1.1 16.4 9.9 13.5 1.1 16.1 9.9 9.9 1.2 16.1 6.8 301 5 300 165 0.4 0.1 0.7 0.2 11/10/2005 15:20:00 13.9 1 16.8 11.5 13.8 1 16.8 11.5 10.6 1.3 14.1 8 300 6 296 165 0.2 0 0.4 -0.1 11/10/2005 15:30:00 14.4 1.1 17.2 10.3 14.3 1.1 17.2 10.3 10.4 1.2 14.5 7.6 301 6 302 165 0.1 0 0.2 -0.1 11/10/2005 15:40:00 14.4 1.2 17.2 10.7 14.4 1.2 17.6 10.7 10.2 1.1 14.5 7.6 302 4 302 165 -0.1 0 -0.1 -0.3 11/10/2005 15:50:00 14.3 1.3 18.3 10.3 14.2 1.3 17.9 10.3 10.8 1.5 15.6 7.2 303 5 305 165 -0.2 0 -0.1 -0.5 11/10/2005 16:00:00 13.1 1.7 17.6 8.8 13 1.7 17.2 8.8 10.5 1.4 15.6 7.2 305 7 298 165 -0.3 0 -0.1 -0.5 11/10/2005 16:10:00 14.1 1.4 17.2 10.7 14.1 1.5 17.2 10.3 10.6 1.4 14.5 7.6 303 6 302 165 -0.3 0 -0.3 -0.5 11/10/2005 16:20:00 15.1 1.2 17.6 10.7 15.1 1.2 17.6 10.7 11 1.5 15.6 8.4 303 5 302 165 -0.7 0 -0.5 -0.8 11/10/2005 16:30:00 14.3 1.5 17.6 9.9 14.2 1.5 17.9 10.3 11.5 1.4 15.3 8 307 5 302 165 -0.9 0 -0.8 -1 11/10/2005 16:40:00 15 1.2 17.9 10.7 14.9 1.3 17.9 10.7 11.5 1.5 16.4 8 305 5 300 165 -1.1 0 -0.8 -1.2 11/10/2005 16:50:00 14.5 1.8 18.3 10.3 14.5 1.8 17.9 10.3 10.8 1.3 14.5 7.2 304 5 298 165 -1.2 0 -1.2 -1.4 11/10/2005 17:00:00 13.7 1.8 16.8 10.3 13.6 1.8 17.2 9.9 10.9 1.7 16.4 7.2 306 6 300 165 -1.2 0 -1.2 -1.2 11/10/2005 17:10:00 12.6 1.1 14.9 9.9 12.6 1.1 14.9 9.9 9.8 1.5 13.7 6.8 305 7 298 165 -1.3 0 -1.2 -1.4 11/10/2005 17:20:00 14.2 1.2 17.2 10.3 14.1 1.2 16.8 9.1 10.9 1.4 14.9 8 306 5 304 165 -1.3 0 -1.2 -1.4 11/10/2005 17:30:00 14.2 1.8 17.9 9.5 14.2 1.9 17.9 9.1 11.3 1.5 16.1 7.6 305 6 302 165 -1.4 0 -1.4 -1.4 11/10/2005 17:40:00 14.8 1.5 17.6 9.5 14.7 1.5 17.6 10.3 11.3 1.5 15.6 7.6 304 6 302 165 -1.4 0 -1.4 -1.7 11/10/2005 17:50:00 14 1.2 16.8 10.7 13.9 1.3 16.4 10.3 11.1 1.5 15.3 8 306 6 310 165 -1.6 0 -1.4 -1.9 11/10/2005 18:00:00 14.4 1.2 16.8 10.7 14.3 1.2 16.8 11.1 11.2 1.5 15.3 7.6 305 5 307 165 -1.6 0 -1.4 -1.9 11/10/2005 18:10:00 13.5 1.2 16.1 10.3 13.4 1.2 16.1 10.3 10.6 1.7 14.5 7.6 305 6 302 165 -1.6 0 -1.4 -1.7 11/10/2005 18:20:00 13.6 1.7 16.4 9.5 13.5 1.7 16.4 9.5 10.5 1.7 14.5 6.8 305 5 304 165 -1.6 0 -1.4 -1.9 11/10/2005 18:30:00 13.7 1.3 16.4 9.5 13.7 1.3 16.8 9.5 10.3 1.3 13.7 6.8 304 5 302 165 -1.6 0 -1.4 -1.9 11/10/2005 18:40:00 13.4 1.2 15.6 9.5 13.3 1.2 15.6 9.9 10.4 1.5 14.1 7.6 305 5 306 165 -1.7 0 -1.4 -1.9 11/10/2005 18:50:00 12.8 1 15.3 9.9 12.8 1 15.3 9.9 9.8 1.3 13.3 6.8 304 5 301 165 -1.7 0 -1.7 -2.1 11/10/2005 19:00:00 13.4 1 15.6 10.7 13.3 1 15.6 10.7 9.9 1.3 14.1 7.6 303 6 301 165 -1.8 0 -1.7 -1.9 11/10/2005 19:10:00 12.9 1.4 16.4 8.8 12.9 1.4 16.4 8.8 10 1.3 14.1 5.7 302 6 291 165 -1.7 0 -1.7 -1.9 11/10/2005 19:20:00 11.8 1.6 14.9 8 11.7 1.6 14.9 8 9.6 1.3 13.3 6.5 304 8 307 165 -1.7 0.1 -1.4 -1.9 11/10/2005 19:30:00 11.1 1.3 14.1 8.4 11 1.3 14.1 8.4 9 1.5 14.5 4.9 302 8 310 165 -1.7 0 -1.7 -2.1 11/10/2005 19:40:00 11.3 1.5 14.1 7.2 11.2 1.4 13.7 7.2 8.8 1.1 11.8 5.7 304 7 305 165 -1.8 0.1 -1.4 -1.9 11/10/2005 19:50:00 10.9 1.2 14.9 8 10.8 1.2 14.9 8.4 9.2 1.4 14.1 6.1 308 9 319 165 -2 0 -1.9 -2.1 11/10/2005 20:00:00 11.7 1.1 15.3 7.6 11.6 1.1 14.9 7.6 9.5 1.5 13.7 6.1 306 6 313 165 -2 0 -1.9 -2.1 11/10/2005 20:10:00 11.5 1.1 13.3 7.6 11.5 1.1 13.3 8.4 8.7 1 11.5 6.5 305 5 301 165 -2.1 0 -1.9 -2.1 11/10/2005 20:20:00 11.5 1 13.7 8.8 11.5 1 13.7 8.4 9.2 1.2 12.6 6.5 306 5 302 165 -2.1 0 -1.9 -2.4 11/10/2005 20:30:00 10.8 0.8 12.6 8.4 10.8 0.8 12.6 8.8 9.1 1.1 12.2 6.8 309 6 307 165 -2.1 0 -1.9 -2.1 11/10/2005 20:40:00 10.8 0.8 12.6 8 10.7 0.8 12.6 8 9.1 1.2 12.2 6.1 309 6 309 165 -2.1 0 -1.9 -2.4 11/10/2005 20:50:00 10.8 1 13.7 8 10.8 1 13.3 8 9 1.2 13.3 6.1 306 7 302 165 -2.2 0 -2.1 -2.4 11/10/2005 21:00:00 11.3 1.2 13.3 7.6 11.3 1.2 13.3 7.6 9.6 1.4 13 6.1 309 7 304 165 -2.2 0 -2.1 -2.6 11/10/2005 21:10:00 11.5 1 13.7 8.4 11.4 1 13.7 8.4 9.5 1.1 12.6 6.5 308 7 306 165 -2.3 0 -2.1 -2.6 11/10/2005 21:20:00 12.6 1.2 14.9 9.1 12.5 1.2 14.9 8.8 10.4 1.5 14.1 6.8 307 5 307 165 -2.3 0 -2.1 -2.6 11/10/2005 21:30:00 12.6 0.9 14.9 10.3 12.6 0.8 14.9 9.9 10.9 1.2 13.7 8 310 5 307 165 -2.2 0 -2.1 -2.6 11/10/2005 21:40:00 11.4 1.1 13.7 8.8 11.3 1.1 13.3 8.4 9.9 1.3 12.6 6.5 309 4 304 165 -2.1 0 -1.9 -2.4 11/10/2005 21:50:00 10.6 1 12.6 8 10.6 1 12.6 8.4 9.3 1.1 11.8 6.1 310 6 304 165 -2.1 0 -1.9 -2.4 11/10/2005 22:00:00 10.2 0.8 12.2 8 10.1 0.9 12.2 8 8.7 1.2 11.1 5.7 309 6 310 165 -2.1 0 -1.9 -2.4 11/10/2005 22:10:00 10.3 1 12.6 7.6 10.2 1 12.6 7.2 8.7 1.1 11.8 5.7 309 5 307 165 -2.1 0 -1.9 -2.4 11/10/2005 22:20:00 10.1 0.8 13 7.6 10.1 0.9 13 7.2 8.8 1.1 11.1 6.1 309 5 303 165 -2 0 -1.9 -2.4 11/10/2005 22:30:00 10.1 0.8 12.6 7.6 10.1 0.8 12.2 7.6 8.2 1.1 11.1 6.1 308 5 301 165 -2 0 -1.9 -2.1 11/10/2005 22:40:00 9.2 0.8 11.5 7.2 9.1 0.8 11.5 6.8 8.8 0.8 11.1 6.5 316 8 312 165 -2 0 -1.9 -2.4 11/10/2005 22:50:00 9.7 0.9 11.5 6.1 9.6 0.9 11.8 6.5 8.3 1 10.3 5.3 308 6 307 165 -2.1 0 -1.9 -2.1 11/10/2005 23:00:00 10.2 0.9 13.3 7.6 10.1 0.9 13.3 8 8.4 1 10.3 4.9 307 5 304 165 -2.2 0 -2.1 -2.4 11/10/2005 23:10:00 10.2 1 13 8.4 10.1 1 13 8 8.5 0.8 10.7 6.1 309 5 304 165 -2.4 0 -2.1 -2.6 11/10/2005 23:20:00 10 0.7 12.2 8 10 1 12.2 6.1 10 0.8 12.2 7.6 339 12 347 165 -2.4 0 -2.1 -2.6 11/10/2005 23:30:00 9.1 0.9 11.1 6.5 8.8 1.4 11.5 4.2 9.1 1.1 11.8 6.1 341 11 349 165 -2.2 0 -2.1 -2.6 11/10/2005 23:40:00 7.7 0.7 9.5 5.7 7.7 0.7 9.9 5.7 7.5 0.7 9.9 5.7 326 9 319 165 -2.3 0 -2.1 -2.4 11/10/2005 23:50:00 6.7 0.6 8.4 5.3 6.6 0.7 8.4 5.3 6.5 0.6 8 4.6 326 12 309 165 -2.4 0 -2.1 -2.6 11/11/2005 00:00:00 6.7 0.6 8 5.3 6.6 0.6 8 4.9 6.6 0.5 8 5.3 323 9 302 165 -2.4 0 -2.1 -2.6 11/11/2005 00:10:00 6.3 0.8 8 4.6 6.1 0.8 8.4 4.2 5.9 0.8 8 3.8 337 11 344 165 -2.4 0 -2.1 -2.6 11/11/2005 00:20:00 6.2 0.8 8.4 4.2 6.1 0.7 8.4 4.2 6 0.6 7.6 4.2 331 13 354 165 -2.3 0 -2.1 -2.6 11/11/2005 00:30:00 6.9 1.1 9.1 3.8 6.3 1.3 9.5 3 6.6 1.3 9.1 4.2 346 10 347 165 -2.4 0 -2.1 -2.6 11/11/2005 00:40:00 7.7 0.8 10.3 5.7 6.7 1.4 10.3 3.8 7.7 1 10.3 5.3 350 8 350 165 -2.4 0 -2.1 -2.6 11/11/2005 00:50:00 8.2 0.9 10.3 5.7 6.1 1.5 9.5 3.4 8.5 0.8 10.3 6.5 354 6 356 165 -2.4 0 -2.1 -2.6 11/11/2005 01:00:00 8.1 0.8 10.3 6.1 6.9 1.5 10.7 3.4 8 1 10.3 4.9 350 6 344 165 -2.4 0 -2.1 -2.6 11/11/2005 01:10:00 8.9 0.9 11.5 6.5 7.7 1.6 11.5 3.8 9.1 1 11.5 6.1 350 6 351 165 -2.5 0 -2.1 -2.6 11/11/2005 01:20:00 8.7 1 11.5 6.5 6.9 1.9 11.1 3 8.5 1.2 11.1 5.3 353 6 350 165 -2.5 0 -2.4 -2.6 11/11/2005 01:30:00 7.3 0.9 9.5 4.9 6.5 1.4 9.1 3.4 6.8 0.9 8.8 4.9 350 7 349 165 -2.5 0 -2.4 -2.6 11/11/2005 01:40:00 7 0.8 9.1 4.6 5.8 1.3 9.1 3 7 0.8 9.1 5.3 351 8 353 165 -2.5 0 -2.4 -2.6 11/11/2005 01:50:00 7.2 0.6 8.8 5.3 6.3 1.3 9.1 3.4 7.2 0.6 8.8 4.6 346 11 347 165 -2.5 0 -2.4 -2.6 11/11/2005 02:00:00 7.1 1 9.1 3.8 5.9 1.6 8.8 2.6 7.2 0.8 9.1 4.2 352 10 350 165 -2.5 0 -2.4 -2.6 11/11/2005 02:10:00 7.1 0.8 9.1 3.8 5.9 1.2 8.8 3 7.1 1 9.5 4.6 354 9 358 165 -2.5 0 -2.6 -2.6 11/11/2005 02:20:00 6.5 0.9 8.8 4.2 5.8 1.1 8 3 6.5 1 8.8 4.2 342 12 355 165 -2.5 0 -2.6 -2.8 11/11/2005 02:30:00 6.7 0.7 8.8 4.6 6.5 0.9 8.4 3.8 6.5 0.7 8.4 4.2 333 12 321 165 -2.5 0 -2.6 -2.8 11/11/2005 02:40:00 7.2 0.6 8.4 5.3 7.1 0.7 8.8 4.2 6.9 0.5 8.4 4.9 338 10 341 165 -2.6 0 -2.6 -2.8 11/11/2005 02:50:00 6.8 1 9.5 4.9 6.5 1 9.1 4.2 6.8 0.9 9.1 4.6 339 10 353 165 -2.6 0 -2.6 -2.8 11/11/2005 03:00:00 6.6 0.8 9.1 3.8 5.5 1.1 8 2.3 6.5 0.9 9.1 4.2 345 15 351 165 -2.6 0 -2.6 -2.8 11/11/2005 03:10:00 7.6 0.7 9.1 6.1 6.7 1.2 9.1 3.4 7.5 0.7 9.1 4.9 349 8 343 165 -2.6 0 -2.6 -2.8 11/11/2005 03:20:00 7.2 0.9 9.5 4.9 6.4 1.3 9.1 3.4 7 1 9.1 4.9 346 10 346 165 -2.7 0 -2.6 -2.8 11/11/2005 03:30:00 7.1 0.9 9.1 4.9 7.1 1 9.1 4.9 6.8 0.9 9.1 4.9 338 10 347 165 -2.8 0 -2.6 -2.8 11/11/2005 03:40:00 6.9 0.8 9.1 4.9 6.6 1.1 9.1 3.4 6.8 0.8 9.1 4.6 343 11 339 165 -2.8 0 -2.6 -3 11/11/2005 03:50:00 7.4 0.8 9.1 5.3 7.2 1.2 9.1 3 7.4 0.8 9.9 5.3 343 8 337 165 -2.7 0 -2.6 -2.8 11/11/2005 04:00:00 7.4 0.6 8.8 5.3 6.7 1.1 9.1 3.8 7.3 0.7 8.8 4.6 348 6 351 165 -2.8 0 -2.8 -3 11/11/2005 04:10:00 7.5 0.7 9.9 5.7 6.7 1.3 9.9 3.8 7.7 0.7 10.7 5.3 348 9 357 165 -2.8 0 -2.6 -3 11/11/2005 04:20:00 7.2 0.6 8.8 5.7 6.9 0.9 8.8 4.2 7.2 0.5 8.4 5.3 346 5 352 165 -2.8 0 -2.8 -3 11/11/2005 04:30:00 6.9 0.8 8.8 4.2 6.5 1 8.8 3.8 7 0.8 9.1 4.9 346 6 356 165 -2.8 0 -2.8 -3 11/11/2005 04:40:00 6.6 0.6 8.8 5.3 5.7 1 8.4 3 6.5 0.8 8.4 4.6 350 5 356 165 -2.8 0 -2.6 -3 11/11/2005 04:50:00 6.7 0.7 8.4 4.9 6.3 1.2 9.1 2.6 6.6 0.7 8 4.9 346 7 345 165 -2.8 0 -2.8 -3 11/11/2005 05:00:00 6.2 0.8 8 4.6 6 1 8.4 3 6.1 0.8 8 4.2 339 10 352 165 -2.8 0 -2.8 -3 11/11/2005 05:10:00 6.2 0.6 8.4 4.2 6.1 0.6 8.4 3.8 5.8 0.6 7.6 4.2 320 11 306 165 -2.9 0 -2.8 -3 11/11/2005 05:20:00 7.2 0.8 8.8 4.9 5.8 1.3 8.8 3 6.9 0.9 8.4 4.9 352 8 349 165 -2.9 0 -2.8 -3.3 11/11/2005 05:30:00 6.9 0.8 8.8 4.9 6.8 0.8 9.1 4.6 6.9 0.8 9.1 4.6 344 6 348 165 -2.9 0 -2.8 -3 11/11/2005 05:40:00 6.8 1 9.5 3.4 6.4 1.1 9.1 2.6 6.7 1.1 9.1 3.8 344 8 353 165 -2.9 0 -2.8 -3 11/11/2005 05:50:00 7.5 0.6 9.1 6.1 7.2 0.8 9.1 4.9 7.5 0.7 9.1 5.7 345 5 354 165 -3 0 -2.8 -3 11/11/2005 06:00:00 8.1 0.8 9.9 5.7 6.6 1.5 9.9 3.4 8.2 0.7 9.9 6.5 351 6 356 165 -3 0 -2.8 -3 11/11/2005 06:10:00 7.5 0.7 9.5 6.1 6.4 1.4 9.1 3 7.9 0.6 9.9 6.1 349 8 358 165 -3 0 -2.8 -3 11/11/2005 06:20:00 7.9 0.9 9.9 5.7 7.7 1 9.9 4.6 7.9 1 9.9 5.3 342 9 347 165 -3 0 -2.8 -3 11/11/2005 06:30:00 7.7 1 9.9 5.3 7.3 1.3 10.3 3.4 7.8 1.1 10.3 4.6 345 7 346 165 -3 0 -2.8 -3.3 11/11/2005 06:40:00 8.1 1 10.7 5.3 7.8 1.2 10.7 4.6 8.2 1 10.7 5.7 344 8 356 165 -2.9 0 -2.8 -3 11/11/2005 06:50:00 8.1 0.7 9.5 6.1 6.9 1.5 9.9 3.4 8.3 0.7 10.3 6.5 350 7 341 165 -3 0 -2.8 -3 11/11/2005 07:00:00 7.5 0.7 9.9 5.3 6.8 1.1 9.9 3.8 7.4 0.9 9.9 4.9 347 7 347 165 -3 0 -2.8 -3.3 11/11/2005 07:10:00 7.8 1 9.5 4.9 7 1.3 9.5 3.8 7.9 1 9.9 4.9 348 6 348 165 -3 0 -2.8 -3.3 11/11/2005 07:20:00 6.9 0.8 8.8 4.9 6.7 1 9.1 3.8 6.8 0.9 9.1 4.6 340 9 348 165 -3 0 -2.8 -3.3 11/11/2005 07:30:00 7.1 0.7 8.8 4.9 6.3 1.1 8.8 3.4 7.2 0.8 8.8 4.9 344 12 354 165 -3 0 -2.8 -3.3 11/11/2005 07:40:00 7.4 0.8 9.5 5.3 6.9 1.3 9.9 3.4 7.2 0.8 9.1 4.9 346 6 347 165 -3 0 -2.8 -3 11/11/2005 07:50:00 6.9 0.5 8.4 5.7 6.5 0.9 8.4 3.8 6.6 0.6 8.4 4.6 344 7 334 165 -3 0 -2.8 -3.3 11/11/2005 08:00:00 6.6 0.6 8 4.9 6.6 0.7 8.4 3.8 6.4 0.6 8 4.6 338 10 338 165 -3 0 -2.8 -3.3 11/11/2005 08:10:00 7.5 0.5 8.8 6.1 6.3 1.5 8.8 3 7.5 0.5 8.8 5.7 350 5 340 165 -3 0 -2.8 -3.3 11/11/2005 08:20:00 7.2 0.7 8.8 5.3 6.6 1.2 9.1 3.8 7.5 0.6 8.8 6.1 348 6 349 165 -3 0 -3 -3.3 11/11/2005 08:30:00 7.4 0.7 9.1 5.7 6.5 1.2 9.1 3.8 7.5 0.7 9.5 5.3 350 5 356 165 -3 0 -2.8 -3.3 11/11/2005 08:40:00 7.1 0.6 8.8 5.7 6.5 1.2 8.8 3 7.2 0.6 8.8 5.7 348 6 339 165 -3 0 -2.8 -3.3 11/11/2005 08:50:00 6.8 0.8 8.4 4.6 6 1.1 8.4 3 7.1 0.6 8.4 5.7 349 7 351 165 -3 0 -2.8 -3.3 11/11/2005 09:00:00 6.6 0.7 8.8 4.9 6.2 1.1 8.8 3.4 6.4 0.9 8.4 4.6 336 17 307 165 -3 0 -2.8 -3.3 11/11/2005 09:10:00 6.9 0.8 9.1 4.9 6.8 0.8 9.1 4.9 6.4 0.8 8.4 4.2 324 16 304 165 -3 0 -2.8 -3.3 11/11/2005 09:20:00 7.2 0.6 8.8 5.3 7.2 0.6 9.1 4.6 7.2 0.6 9.1 5.3 342 6 338 165 -2.8 0 -2.6 -3 11/11/2005 09:30:00 6.6 0.6 8 4.9 6.3 1 8.4 3 6.7 0.6 8.4 4.9 343 8 342 165 -2.6 0 -2.6 -3 11/11/2005 09:40:00 5.7 0.7 7.6 3.4 5.7 0.8 7.6 3.8 5.4 0.9 7.6 3 319 15 338 165 -2.6 0 -2.6 -2.8 11/11/2005 09:50:00 6.6 1 9.1 4.2 6.5 1 9.5 4.2 5.5 0.9 8.4 3 304 10 295 165 -2.8 0 -2.6 -2.8 11/11/2005 10:00:00 6.9 0.8 9.1 4.9 6.9 0.8 8.8 4.9 5.8 1 9.5 3.8 303 10 292 165 -2.8 0 -2.6 -3 11/11/2005 10:10:00 6.6 0.8 8.8 4.6 6.6 0.8 8.8 4.6 5.7 0.8 8.4 3.8 307 9 298 165 -2.7 0 -2.6 -2.8 11/11/2005 10:20:00 6.7 0.9 8.8 4.9 6.7 0.8 8.8 4.6 5.6 0.8 7.6 3.8 304 9 306 165 -2.5 0 -2.6 -2.8 11/11/2005 10:30:00 8.2 0.9 10.7 5.3 8.2 0.9 10.7 5.7 6.7 0.9 9.9 3.8 300 9 308 165 -2.5 0 -2.6 -2.8 11/11/2005 10:40:00 7.1 0.7 9.1 5.3 7.1 0.7 8.8 5.3 5.7 0.9 8.8 3.8 301 7 305 165 -2.5 0 -2.4 -2.8 11/11/2005 10:50:00 7.1 0.7 8.4 4.9 7.1 0.7 8.4 5.3 5.9 1 8.4 3.8 299 10 307 165 -2.4 0 -2.1 -2.6 11/11/2005 11:00:00 7.5 0.8 9.5 5.7 7.4 0.8 9.5 5.7 6.3 0.9 8.8 4.2 306 8 307 165 -2.3 0 -2.1 -2.6 11/11/2005 11:10:00 6.4 0.7 8.4 4.6 6.4 0.7 8.4 4.6 5.1 0.7 7.6 3.4 303 8 307 165 -2.1 0.3 -1.4 -2.6 11/11/2005 11:20:00 6 0.7 8 4.6 5.9 0.7 8.4 4.6 4.7 0.8 7.2 3 301 7 298 165 -1.2 0 -1 -1.4 11/11/2005 11:30:00 5.5 0.8 7.2 3 5.5 0.8 7.6 3.4 4.7 0.9 6.8 2.3 301 9 296 165 -1.6 0 -1.2 -1.9 11/11/2005 11:40:00 5.8 0.6 7.6 4.2 5.7 0.6 7.2 4.2 5.1 0.8 8 3.4 301 13 297 165 -1.8 0.1 -1.4 -1.9 11/11/2005 11:50:00 5.6 0.5 6.8 4.6 5.5 0.5 6.5 4.2 5.4 0.5 6.8 4.2 316 7 313 165 -1.7 0 -1.4 -1.9 11/11/2005 12:00:00 5.7 0.6 7.2 4.6 5.7 0.6 7.2 4.2 5.2 0.9 7.2 3 312 9 328 165 -1.8 0 -1.7 -1.9 11/11/2005 12:10:00 6.1 0.8 8 4.2 6 0.7 8 4.2 5.8 0.7 7.6 3.8 317 12 297 165 -1.9 0 -1.7 -2.1 11/11/2005 12:20:00 6.4 0.8 8.8 4.2 6.4 0.8 8.4 4.2 5.3 0.8 8 3.4 304 10 294 165 -2 0 -1.9 -2.1 11/11/2005 12:30:00 5.3 0.8 7.2 3 5.2 0.7 7.2 3 4.6 0.7 6.5 2.6 307 10 307 165 -1.9 0 -1.7 -2.1 11/11/2005 12:40:00 5.2 0.7 6.8 3.4 5.1 0.7 6.8 3 4.4 0.7 6.1 2.6 299 12 290 165 -2 0 -1.9 -2.1 11/11/2005 12:50:00 5.2 0.5 6.5 3.8 5.2 0.5 6.8 3.8 4.7 0.7 6.8 3 310 11 303 165 -1.7 0 -1.4 -2.1 11/11/2005 13:00:00 6.5 0.8 8.4 4.6 6.4 0.8 8.4 4.2 6.3 0.8 8 4.6 332 9 328 165 -1.5 0.1 -1.4 -1.9 11/11/2005 13:10:00 6.4 0.6 8 4.6 6.4 0.7 8 4.6 6.4 0.6 8 4.6 335 6 339 165 -1.5 0 -1.4 -1.7 11/11/2005 13:20:00 5.3 0.6 7.2 3.8 5.2 0.6 6.8 3.8 5.1 0.6 6.8 3.4 330 10 340 165 -1.6 0 -1.4 -1.9 11/11/2005 13:30:00 7.1 1 9.9 4.9 7.1 1 9.9 4.9 7 1.1 9.9 4.6 327 9 334 165 -1.6 0 -1.4 -1.9 11/11/2005 13:40:00 7 1 9.1 5.3 6.9 1 9.1 4.9 6.8 1.1 9.5 4.6 324 10 328 165 -1.4 0 -1.2 -1.7 11/11/2005 13:50:00 6.8 0.6 8.4 5.7 6.7 0.6 8.4 5.7 6.6 0.6 8.4 4.9 320 8 314 165 -0.8 0 -0.5 -1.4 11/11/2005 14:00:00 7.3 0.7 9.5 5.7 7.2 0.7 9.9 5.3 6.9 0.9 9.1 4.6 321 12 349 165 -0.8 0 -0.5 -1 11/11/2005 14:10:00 7.2 1.2 10.3 3.8 7.2 1.2 10.3 4.2 7 1.2 9.9 3.8 330 11 339 165 -1.3 0.1 -1 -1.4 11/11/2005 14:20:00 6.1 0.8 9.1 4.6 6.1 0.8 9.1 4.6 6 0.7 8 4.6 322 11 329 165 -1.6 0 -1.4 -1.7 11/11/2005 14:30:00 6.5 0.8 8.8 4.6 6.5 0.9 8.8 4.2 6.2 1 9.1 3.8 324 14 330 165 -1.6 0 -1.4 -1.9 11/11/2005 14:40:00 7.4 0.9 9.9 5.3 7.4 0.9 9.5 5.3 6 0.8 8.8 4.2 299 8 289 165 -1.8 0.1 -1.7 -1.9 11/11/2005 14:50:00 8.1 1 9.9 5.3 8 1 9.9 5.3 6.4 1 10.3 3.8 298 8 291 165 -2 0 -1.9 -2.1 11/11/2005 15:00:00 6.9 1.1 9.9 4.6 6.8 1.1 9.9 4.2 6 0.7 7.6 4.2 310 13 295 165 -2 0 -1.9 -2.1 11/11/2005 15:10:00 6.6 0.7 8.4 4.9 6.5 0.7 8.4 4.9 5.7 0.7 7.2 4.2 308 7 302 165 -2 0 -1.9 -2.1 11/11/2005 15:20:00 6.8 0.8 8.8 4.9 6.8 0.9 8.8 4.9 5.5 0.7 8 3.4 302 8 291 165 -2 0 -1.9 -2.1 11/11/2005 15:30:00 7.3 0.7 9.1 5.3 7.2 0.7 8.8 4.9 6.8 0.9 9.1 4.2 314 6 300 165 -2 0 -1.9 -2.1 11/11/2005 15:40:00 7.5 0.5 8.8 6.1 7.4 0.5 8.8 6.1 7.1 0.8 8.8 5.3 318 10 333 165 -2 0 -1.9 -2.1 11/11/2005 15:50:00 7.9 0.5 9.1 6.5 7.8 0.5 9.1 6.5 7.4 0.7 8.8 5.3 314 7 312 165 -2.1 0 -1.9 -2.1 11/11/2005 16:00:00 8.3 0.7 9.9 6.1 8.3 0.7 9.9 6.1 7.3 0.8 9.5 5.3 310 7 302 165 -2.2 0 -2.1 -2.4 11/11/2005 16:10:00 7.4 0.7 9.5 5.7 7.3 0.8 9.1 5.7 7.3 0.8 9.5 5.3 327 8 339 165 -2.1 0 -1.9 -2.4 11/11/2005 16:20:00 7.3 0.8 9.1 4.9 7.2 0.8 9.1 4.9 7.2 0.8 9.5 4.9 326 8 322 165 -2 0 -1.9 -2.1 11/11/2005 16:30:00 7.7 1 10.3 5.3 7.6 1 9.5 5.7 7.4 1.2 9.9 4.2 322 10 325 165 -2 0 -1.9 -2.1 11/11/2005 16:40:00 8.2 0.8 9.9 6.5 8.1 0.8 9.9 6.5 7.5 0.9 9.9 5.3 312 9 305 165 -2.1 0 -1.9 -2.4 11/11/2005 16:50:00 9.5 0.7 11.5 7.2 9.5 0.7 11.1 7.2 7.9 1 10.7 5.3 308 5 308 165 -2.1 0 -2.1 -2.4 11/11/2005 17:00:00 9.1 1 11.1 6.5 9 1.1 11.5 5.7 7.7 1.1 10.3 4.6 307 9 297 165 -2.1 0 -1.9 -2.6 11/11/2005 17:10:00 8.7 0.9 11.1 5.7 8.7 0.8 10.7 5.7 7.1 1 10.7 4.9 304 9 298 165 -2.1 0 -1.9 -2.4 11/11/2005 17:20:00 8.5 1.2 11.5 4.9 8.4 1.1 11.1 4.9 7.2 1.1 11.5 4.9 310 12 310 165 -2 0 -1.9 -2.1 11/11/2005 17:30:00 9.2 0.8 11.1 7.2 9.1 0.8 11.1 7.2 7.5 0.8 9.9 4.9 305 7 302 165 -2 0 -1.9 -2.1 11/11/2005 17:40:00 8.7 0.8 10.7 6.5 8.6 0.8 10.7 6.5 7.6 0.9 9.9 5.3 310 8 298 165 -2.1 0 -1.9 -2.1 11/11/2005 17:50:00 8.4 1.1 11.5 5.7 8.3 1.1 11.1 5.7 7.1 1 10.3 4.2 303 9 298 165 -2.1 0 -1.9 -2.4 11/11/2005 18:00:00 8.2 1 10.7 5.3 8.2 1 10.3 5.3 7 1.1 10.3 4.6 297 9 300 165 -2 0 -1.9 -2.1 11/11/2005 18:10:00 8.2 1 12.2 5.7 8.2 1 11.8 5.7 6.6 1 10.3 4.6 303 9 290 165 -2 0 -1.9 -2.4 11/11/2005 18:20:00 8.1 1.3 11.1 4.9 8 1.3 11.1 4.9 6.8 0.9 9.1 4.6 304 9 296 165 -2 0 -1.9 -2.1 11/11/2005 18:30:00 7.5 0.8 9.1 5.7 7.4 0.8 8.8 5.7 6.2 0.9 8.8 4.2 303 9 294 165 -2 0 -1.9 -2.1 11/11/2005 18:40:00 7.9 1.2 10.7 4.9 7.8 1.2 10.7 4.9 6.5 0.9 9.1 3.4 304 9 293 165 -2 0 -1.9 -2.1 11/11/2005 18:50:00 7.1 1.1 9.9 4.6 7.1 1.1 9.5 4.6 6.3 0.9 9.5 3.8 310 7 316 165 -2.1 0 -1.9 -2.1 11/11/2005 19:00:00 6.4 0.9 8.8 4.2 6.3 0.9 8.4 4.2 5.7 0.9 8.8 3 313 10 299 165 -2 0 -1.9 -2.4 11/11/2005 19:10:00 7.1 0.7 9.1 4.9 7 0.7 8.8 4.9 6.3 0.9 8.8 3.8 309 8 318 165 -2 0 -1.9 -2.1 11/11/2005 19:20:00 7.2 0.7 8.8 5.3 7.1 0.7 8.8 5.3 6.6 0.8 8.4 4.6 311 8 307 165 -2.1 0 -2.1 -2.4 11/11/2005 19:30:00 6.3 0.8 8.4 4.2 6.2 0.8 8.4 4.2 5.5 1 8.4 3 310 11 307 165 -2.1 0 -1.9 -2.4 11/11/2005 19:40:00 6 0.7 7.6 3.8 6 0.8 7.6 3.4 5.2 0.7 6.8 3.4 306 8 305 165 -2.1 0 -1.9 -2.1 11/11/2005 19:50:00 5.3 0.5 6.8 3.4 5.3 0.5 6.8 3.4 4.9 0.6 6.8 3 315 9 319 165 -2.1 0 -1.9 -2.4 11/11/2005 20:00:00 5.8 0.6 8 4.6 5.7 0.6 8 4.6 5.5 0.7 8 2.6 318 10 324 165 -2.1 0 -1.9 -2.4 11/11/2005 20:10:00 7.9 1 9.9 5.7 7.9 1 10.3 4.9 7.7 1.1 10.3 4.6 336 8 339 165 -1.9 0 -1.7 -2.1 11/11/2005 20:20:00 6.7 1 9.5 4.2 6.6 1 9.5 4.2 6.6 1 9.1 4.2 329 12 343 165 -1.7 0 -1.4 -2.1 11/11/2005 20:30:00 7.1 1.3 10.3 4.6 6.9 1.3 9.9 4.6 7 1.3 10.7 4.2 328 13 350 165 -1.5 0 -1.4 -1.7 11/11/2005 20:40:00 6.6 1.2 9.5 4.2 6 1.3 9.5 3 6.6 1.2 9.1 4.2 340 15 357 165 -1.6 0 -1.4 -1.7 11/11/2005 20:50:00 7.5 1.2 11.1 4.9 7.5 1.2 11.1 4.9 7.5 1.2 11.5 4.9 333 10 338 165 -1.6 0 -1.4 -1.9 11/11/2005 21:00:00 7.8 1.2 11.1 5.3 7.6 1.3 11.5 4.6 7.6 1.2 11.1 4.2 338 11 338 165 -1.6 0 -1.4 -1.9 11/11/2005 21:10:00 8.5 1.2 11.5 5.3 8.2 1.5 11.1 4.6 8.2 1.2 11.1 5.3 334 11 328 165 -1.5 0 -1.4 -1.9 11/11/2005 21:20:00 7.9 1 10.7 5.3 8 1 11.1 5.7 7.9 1.1 10.3 5.7 335 8 336 165 -1.4 0 -1.2 -1.7 11/11/2005 21:30:00 8.1 1.1 11.5 6.1 8.1 1.2 11.5 5.7 7.8 1.1 11.1 5.3 336 8 333 165 -1.4 0 -1.4 -1.7 11/11/2005 21:40:00 8.3 1.2 11.8 5.3 8.2 1.2 11.8 5.7 8.2 1.2 11.8 5.3 332 9 332 165 -1.4 0 -1.2 -1.4 11/11/2005 21:50:00 7.4 1.1 9.9 4.2 7.2 1.2 10.3 4.2 7.2 1.1 9.9 3.8 333 13 342 165 -1.3 0 -1.2 -1.4 11/11/2005 22:00:00 8.6 1.1 11.5 6.5 8.6 1.3 12.2 5.7 8.5 1.2 11.1 5.7 335 11 339 165 -1.4 0 -1.2 -1.4 11/11/2005 22:10:00 9.5 1.4 12.6 6.5 9.3 1.7 13 4.6 9.3 1.4 12.6 6.1 340 10 338 165 -1.6 0 -1.4 -1.7 11/11/2005 22:20:00 8 1.1 11.8 5.7 7.6 1.2 10.3 4.2 8 1.1 12.6 5.7 341 12 353 165 -1.6 0 -1.4 -1.9 11/11/2005 22:30:00 7.8 1.2 11.5 5.7 7.8 1.3 11.8 5.7 7.9 1.3 11.8 5.7 337 10 347 165 -1.4 0 -1.2 -1.7 11/11/2005 22:40:00 9.5 1.5 13 6.5 9.5 1.7 13.7 5.3 9.5 1.5 13.3 6.1 340 8 337 165 -1.4 0 -1.4 -1.4 11/11/2005 22:50:00 9.6 1.3 12.2 6.1 9.6 1.4 12.6 4.2 9.6 1.5 13 5.3 337 7 333 165 -1.4 0 -1.4 -1.9 11/11/2005 23:00:00 8.9 1.6 13 5.7 8.8 1.7 13 4.6 8.9 1.6 13.3 5.7 335 10 338 165 -1.4 0 -1.2 -1.7 11/11/2005 23:10:00 8 1.5 11.5 4.2 7.8 1.6 11.5 3.4 7.9 1.2 11.1 5.7 338 10 328 165 -1.2 0 -1.2 -1.4 11/11/2005 23:20:00 7.3 1.2 11.5 4.9 7.1 1.3 11.8 4.6 6.8 1.3 11.1 4.2 328 16 337 165 -1.3 0 -1.2 -1.4 11/11/2005 23:30:00 7.2 1.4 10.3 2.6 7 1.4 10.7 2.6 7 1.5 10.3 2.3 324 20 350 165 -1.4 0 -1.2 -1.4 11/11/2005 23:40:00 6.5 1.4 10.7 2.3 6.4 1.4 11.1 2.3 6.1 1.5 10.3 3 330 17 338 165 -1.3 0 -1.2 -1.4 11/11/2005 23:50:00 8.4 1.1 11.1 5.3 6.7 1.4 10.7 3.4 8.4 1.1 10.7 4.9 353 9 357 165 -1.1 0 -1 -1.7 11/12/2005 00:00:00 8.2 1.5 13 5.3 7.2 1.5 11.8 3.8 8.3 1.5 12.2 4.9 347 13 357 165 -0.9 0 -0.8 -1.2 11/12/2005 00:10:00 7.7 1.3 11.1 4.6 6.8 1.2 9.9 4.2 8 1.1 10.7 5.3 346 11 357 165 -0.9 0 -0.8 -1.2 11/12/2005 00:20:00 10 1.3 13.3 6.5 8.8 2.1 13.3 4.2 10 1.3 13 6.8 350 8 355 165 -0.9 0 -0.8 -1.2 11/12/2005 00:30:00 8.2 1.1 12.2 4.9 7.7 1.1 11.1 4.2 8.5 1.1 12.6 5.7 343 13 3 165 -1 0.1 -0.8 -1.2 11/12/2005 00:40:00 8.6 1 11.1 6.1 7.4 1.5 11.5 4.6 8.7 1 10.7 6.5 351 12 338 165 -1 0.1 -0.8 -1.4 11/12/2005 00:50:00 9.2 1.2 12.2 5.3 8.1 1.5 12.2 3.8 9.4 1.5 13.3 5.7 345 11 353 165 -0.9 0 -0.8 -1.2 11/12/2005 01:00:00 8.7 1 11.8 5.7 8.5 1 11.5 5.3 8.8 0.9 11.5 6.8 335 15 1 165 -1 0.2 -0.8 -1.4 11/12/2005 01:10:00 8.6 1 11.1 6.1 8 1.3 11.8 4.6 8.7 1 11.1 6.1 343 12 355 165 -1 0.2 -0.5 -1.4 11/12/2005 01:20:00 9 1.7 13 3.4 8.9 1.8 12.6 3 7.8 1.2 11.1 4.9 311 22 288 165 -0.9 0.4 -0.3 -1.7 11/12/2005 01:30:00 9.2 1.4 11.8 4.9 9.1 1.4 11.8 4.6 7.4 1.2 10.3 4.2 301 15 305 165 -1.6 0 -1.4 -1.9 11/12/2005 01:40:00 5.5 1 9.1 3.4 5.2 1.1 9.5 3 5.4 1.2 9.1 3.4 336 15 326 165 -1.5 0 -1.2 -1.9 11/12/2005 01:50:00 4.9 0.9 7.6 2.6 4.8 1 7.6 2.3 4.5 1 7.6 2.3 317 21 337 165 -1.2 0 -1 -1.4 11/12/2005 02:00:00 6.3 1.6 10.3 3 6.2 1.6 10.7 2.6 6 1.6 10.3 2.6 327 16 328 165 -0.6 0.3 -0.3 -1.4 11/12/2005 02:10:00 8 1.2 11.1 4.6 7.9 1.2 11.1 5.3 7.7 1.3 10.3 4.6 327 9 322 165 -0.2 0 -0.1 -0.5 11/12/2005 02:20:00 9.3 1 12.6 6.8 9.2 1 12.6 6.5 9 1.1 12.6 6.1 323 9 339 165 -0.6 0.1 -0.1 -0.8 11/12/2005 02:30:00 8.6 1.2 11.8 6.1 8.5 1.2 11.5 6.1 8.2 1.3 11.1 5.3 320 9 323 165 -0.6 0 -0.3 -0.8 11/12/2005 02:40:00 7.9 0.9 10.7 4.9 7.8 1 10.3 4.2 7.7 1 10.3 4.6 329 12 314 165 -0.3 0 -0.1 -0.5 11/12/2005 02:50:00 9.9 1.2 14.1 6.8 9.8 1.2 13.7 6.8 9.5 1.3 13.7 6.1 328 9 323 165 -0.1 0 -0.1 -0.5 11/12/2005 03:00:00 9.4 1.1 11.8 6.1 9.3 1.1 12.2 5.3 9.2 1.1 12.2 6.1 329 11 344 165 -0.1 0 0.2 -0.3 11/12/2005 03:10:00 9.2 0.9 11.8 6.8 9.1 0.8 11.5 6.8 9 0.8 11.8 7.2 324 9 327 165 -0.3 0.1 0.2 -0.5 11/12/2005 03:20:00 9.3 1.3 14.1 5.7 9.2 1.4 13.7 6.1 9.1 1.5 14.1 5.3 330 12 332 165 -0.4 0.1 -0.1 -0.8 11/12/2005 03:30:00 9.2 1.2 12.6 6.1 9.1 1.4 12.6 5.7 9.1 1.2 12.6 5.7 334 10 333 165 0.1 0 0.2 -0.3 11/12/2005 03:40:00 8.9 1.1 11.5 5.7 8.8 1.1 12.2 6.1 8.8 1.2 13.7 5.7 324 8 329 165 -0.2 0.1 0.2 -0.3 11/12/2005 03:50:00 8.8 1.7 13.7 5.7 8.9 1.8 14.1 6.1 8.8 1.7 13.3 6.5 331 10 333 165 -0.2 0 -0.1 -0.5 11/12/2005 04:00:00 9.7 1.1 13.7 6.5 9.7 1.3 13.7 5.7 9.8 1.1 13.3 6.1 336 10 332 165 0.2 0 0.2 -0.3 11/12/2005 04:10:00 9.5 1 12.2 7.2 9.4 1 12.2 6.8 9.6 1 12.2 6.5 335 9 328 165 0.1 0 0.2 -0.1 11/12/2005 04:20:00 10.1 1.2 13 6.8 9.3 1.9 13 4.6 10.2 1.2 13.7 6.5 344 9 353 165 0.4 0 0.7 0.2 11/12/2005 04:30:00 9.3 1.2 13 6.5 8.7 1.7 12.6 3.8 9.3 1.2 13.3 6.1 342 10 330 165 0.3 0 0.7 0.2 11/12/2005 04:40:00 8.6 1.1 11.1 6.5 8.4 1.4 11.5 3.8 8.7 1.2 11.8 6.8 342 8 355 165 0.4 0 0.7 0.2 11/12/2005 04:50:00 9.3 1 11.8 6.8 9.4 1 11.8 6.8 9.3 1 11.8 6.8 335 7 329 165 0.4 0 0.7 0.2 11/12/2005 05:00:00 8.9 0.9 11.1 6.8 9 1 11.5 6.5 8.8 0.9 11.1 6.5 338 7 347 165 0.4 0 0.7 0.2 11/12/2005 05:10:00 8.8 1.2 11.1 6.1 8.1 2.1 11.5 3 8.8 1.2 11.5 6.1 346 8 342 165 0.3 0 0.7 0.2 11/12/2005 05:20:00 8 0.8 10.3 6.1 6.9 1.6 9.9 3.4 8.1 0.9 11.1 5.7 350 6 0 165 0.2 0 0.2 0.2 11/12/2005 05:30:00 6.5 0.9 8.8 4.6 5.2 1.5 8.4 2.3 6.6 0.8 9.5 5.3 354 9 341 165 0.2 0 0.4 -0.1 11/12/2005 05:40:00 5.9 0.7 8.4 4.6 4.4 1.1 6.8 2.3 5.9 0.7 8 4.6 355 7 357 165 0.2 0 0.4 0.2 11/12/2005 05:50:00 4.9 0.5 6.1 3.8 3.8 0.9 5.7 2.3 5 0.5 6.1 3.8 353 8 350 165 0.1 0 0.2 -0.1 11/12/2005 06:00:00 4.1 0.5 6.1 3 3.4 0.7 4.9 1.9 4.3 0.6 6.1 2.6 347 17 3 165 0.1 0 0.2 -0.1 11/12/2005 06:10:00 4.6 0.5 5.7 3.4 4.6 0.5 5.7 3 4.5 0.5 5.7 3.4 331 9 332 165 -0.1 0 0.2 -0.3 11/12/2005 06:20:00 4.1 0.5 5.7 3 4.1 0.6 6.1 3 4.1 0.6 5.7 2.6 328 9 332 165 -0.3 0 -0.1 -0.3 11/12/2005 06:30:00 3.2 0.5 4.6 2.3 2.6 0.8 4.6 0.7 3.1 0.4 4.2 2.3 354 9 355 165 -0.3 0 -0.1 -0.5 11/12/2005 06:40:00 4 0.5 4.9 2.6 3.9 0.7 4.9 1.1 3.9 0.5 4.9 2.6 32 13 40 165 0 0.2 0.4 -0.3 11/12/2005 06:50:00 4.1 0.5 5.3 3 4.2 0.5 5.3 3 4.1 0.5 5.3 2.6 45 4 51 165 0.3 0 0.4 0.2 11/12/2005 07:00:00 4.2 0.4 4.9 2.6 4.3 0.4 4.9 2.6 4.3 0.4 5.3 3 44 6 39 165 0.2 0 0.4 0.2 11/12/2005 07:10:00 3.7 0.4 5.3 2.6 3.7 0.4 5.3 2.6 3.9 0.4 5.3 3 47 6 43 165 0.1 0 0.2 -0.1 11/12/2005 07:20:00 4.2 0.5 6.1 2.6 4.3 0.5 6.5 3 4.3 0.4 5.3 3 54 15 84 165 0.1 0 0.2 -0.3 11/12/2005 07:30:00 3.5 0.4 4.6 1.5 3.5 0.5 4.6 1.5 3.6 0.4 4.6 1.9 45 18 40 165 0.1 0 0.2 -0.1 11/12/2005 07:40:00 3.5 0.4 4.9 2.3 3.5 0.5 4.9 2.3 3.6 0.4 4.6 2.3 40 7 29 165 0 0 0.2 -0.1 11/12/2005 07:50:00 3.4 0.5 4.9 1.9 3.4 0.5 4.9 1.9 3.3 0.6 4.6 1.5 58 15 81 165 0 0 0.2 -0.3 11/12/2005 08:00:00 3.5 0.4 4.6 1.9 3.5 0.4 4.6 2.3 3.6 0.4 4.6 2.6 49 8 68 165 0.2 0 0.2 -0.3 11/12/2005 08:10:00 3.7 0.4 4.9 2.3 3.7 0.4 4.9 2.6 3.8 0.2 4.6 3 43 8 58 165 0.2 0 0.2 -0.1 11/12/2005 08:20:00 3.6 0.3 4.6 2.6 3.7 0.4 4.9 2.6 3.7 0.3 4.2 2.6 46 7 43 165 0.4 0 0.7 0.2 11/12/2005 08:30:00 5.7 1.6 8.8 3 5.9 1.7 9.5 3 5.4 1.5 8.8 3 87 22 121 165 0.7 0.2 1.1 0.2 11/12/2005 08:40:00 5.6 1.3 8.8 2.6 5.8 1.3 8.8 2.6 5.4 1.5 9.1 2.3 100 15 111 165 1.1 0 1.4 0.9 11/12/2005 08:50:00 6.6 0.7 8.4 4.6 6.8 0.8 8.8 4.9 6.5 0.8 8.4 4.2 113 7 119 165 0.9 0 1.1 0.7 11/12/2005 09:00:00 5.7 0.7 7.2 3.8 5.9 0.7 7.2 4.2 5.4 0.7 6.8 3.8 103 8 94 165 0.8 0 0.9 0.7 11/12/2005 09:10:00 6.2 0.8 7.6 3.8 6.4 0.8 8 4.2 5.8 0.9 8 3.8 116 9 132 165 0.5 0 0.7 0.2 11/12/2005 09:20:00 6 0.8 8 4.6 6.2 0.8 8.4 4.6 5.7 0.8 8 4.2 120 9 107 165 0.4 0 0.7 0.2 11/12/2005 09:30:00 5.6 0.7 7.6 4.2 5.8 0.7 7.2 4.2 5.4 0.8 7.2 3.8 124 5 129 165 0.5 0 0.9 0.2 11/12/2005 09:40:00 7.3 1 9.9 5.3 7.4 1 9.9 5.3 7.1 1 10.7 5.3 126 6 124 165 0.9 0 1.1 0.7 11/12/2005 09:50:00 7.4 0.4 8.4 6.5 7.6 0.4 8.8 6.1 7.2 0.5 8.4 5.3 121 4 124 165 1.3 0.1 1.6 0.9 11/12/2005 10:00:00 7.7 0.6 9.1 6.1 7.9 0.5 9.5 6.5 7.4 0.6 9.5 5.7 118 4 119 165 1.5 0 1.6 1.4 11/12/2005 10:10:00 8.6 0.8 11.1 6.5 8.8 0.8 11.5 6.5 8.2 1 10.3 5.3 115 5 109 165 1.6 0 1.8 1.4 11/12/2005 10:20:00 8.6 1 10.7 6.1 8.8 1 11.1 6.1 8.4 1.1 11.1 4.9 121 4 124 165 1.7 0 1.8 1.4 11/12/2005 10:30:00 7.7 0.8 9.5 5.7 7.9 0.8 9.9 6.1 7.6 0.7 9.5 5.7 125 5 123 165 1.7 0 1.8 1.4 11/12/2005 10:40:00 6.5 0.6 7.6 4.9 6.7 0.6 8 5.3 6.5 0.7 8 4.9 127 6 122 165 1.8 0 1.8 1.6 11/12/2005 10:50:00 6.4 0.5 8 4.9 6.5 0.5 8 4.9 6.2 0.5 8 4.9 126 5 123 165 1.8 0 1.8 1.6 11/12/2005 11:00:00 6.8 0.8 8.8 4.9 6.9 0.8 8.8 4.9 6.6 0.7 8.8 4.9 127 5 124 165 1.7 0 1.8 1.6 11/12/2005 11:10:00 5.7 0.6 6.8 4.2 5.8 0.6 6.8 4.6 5.4 0.6 6.8 3.8 120 5 127 165 1.8 0 1.8 1.6 11/12/2005 11:20:00 5.9 0.6 7.2 4.6 6.1 0.6 7.6 4.6 5.6 0.7 7.6 3.4 113 4 111 165 1.8 0 1.8 1.6 11/12/2005 11:30:00 6.5 0.5 8 4.9 6.7 0.6 8 4.9 6.3 0.6 8 4.6 123 5 125 165 1.9 0 1.8 1.6 11/12/2005 11:40:00 6.9 0.6 8 4.9 7.1 0.6 8.4 5.3 6.8 0.7 8.8 4.9 122 6 125 165 2 0.1 2.3 1.8 11/12/2005 11:50:00 6.8 0.6 8.4 4.9 7 0.5 8.4 5.3 6.7 0.6 8.4 4.6 121 5 128 165 2.3 0.1 2.6 1.8 11/12/2005 12:00:00 6.9 0.7 8.8 4.9 7 0.7 9.1 4.9 6.8 0.7 8.4 4.9 120 5 126 165 2.6 0.3 2.8 1.8 11/12/2005 12:10:00 6.1 0.6 7.6 4.6 6.3 0.6 8 4.9 5.9 0.5 7.2 4.2 119 5 102 165 1.9 0 2.1 1.8 11/12/2005 12:20:00 7.3 0.6 9.1 5.3 7.5 0.7 9.5 5.3 7 0.6 8.4 5.3 118 6 117 165 2.3 0.2 2.8 1.8 11/12/2005 12:30:00 7.2 0.6 9.5 5.7 7.3 0.6 9.1 6.1 7 0.6 9.5 5.3 124 4 127 165 2.1 0.2 2.6 1.8 11/12/2005 12:40:00 7.3 0.6 9.1 5.7 7.5 0.6 9.5 6.1 7.2 0.7 9.5 5.3 127 6 125 165 1.9 0 2.3 1.8 11/12/2005 12:50:00 7.1 0.6 8.4 5.7 7.3 0.6 8.4 5.7 7 0.6 8.4 4.9 132 6 129 165 2.1 0.2 2.6 1.8 11/12/2005 13:00:00 6 0.8 8 4.2 6.1 0.8 8 4.6 5.9 0.8 8 4.2 132 9 133 165 2 0 2.3 1.8 11/12/2005 13:10:00 5.8 0.5 7.2 4.6 5.9 0.5 7.6 4.6 5.5 0.5 6.8 4.2 120 7 126 165 2 0 2.1 1.8 11/12/2005 13:20:00 6.3 0.8 8.8 4.2 6.5 0.8 9.1 4.6 6.1 0.8 8.4 4.6 121 5 122 165 2.3 0.3 2.8 1.8 11/12/2005 13:30:00 6 0.7 8 3.8 6.1 0.8 8 3.8 5.8 0.8 7.6 3.8 124 12 119 165 2.4 0.1 2.8 2.3 11/12/2005 13:40:00 6.3 0.9 8 3.8 6.5 1 8.4 3.8 6.1 1.1 8 3.4 132 9 122 165 2.6 0.3 3.3 2.3 11/12/2005 13:50:00 6.4 0.5 8 4.6 6.5 0.6 8 4.6 6.3 0.6 7.6 4.6 134 6 130 165 2.5 0.4 3 1.8 11/12/2005 14:00:00 4.6 0.7 6.1 3 4.7 0.7 6.5 3 4.6 0.8 6.8 3 128 6 135 165 1.9 0 2.1 1.8 11/12/2005 14:10:00 4.8 0.5 5.7 2.6 4.9 0.5 6.1 3 4.5 0.6 5.7 3 118 6 123 165 1.9 0 2.1 1.8 11/12/2005 14:20:00 4.3 0.3 5.3 3.4 4.5 0.3 5.3 3.4 4.1 0.4 5.3 3 110 4 105 165 2.1 0 2.3 1.8 11/12/2005 14:30:00 4.3 0.5 5.3 2.6 4.5 0.5 5.7 2.6 4.2 0.5 5.3 2.6 112 5 108 165 1.9 0 1.8 1.8 11/12/2005 14:40:00 4.5 0.3 5.3 3.8 4.6 0.3 5.3 3.8 4.3 0.4 5.3 3 107 6 109 165 1.8 0 1.8 1.6 11/12/2005 14:50:00 3.9 0.4 4.9 3 4 0.4 4.9 3 3.7 0.5 4.9 2.3 101 5 96 165 1.8 0 1.8 1.6 11/12/2005 15:00:00 4.2 0.3 4.9 3 4.3 0.3 5.3 3.4 3.9 0.4 4.9 2.6 102 5 103 165 1.9 0 1.8 1.8 11/12/2005 15:10:00 4.7 0.6 6.1 3 4.9 0.6 6.1 3 4.4 0.6 6.1 2.6 95 6 97 165 1.8 0 1.8 1.6 11/12/2005 15:20:00 5 0.3 5.7 4.2 5.2 0.3 6.1 4.6 4.9 0.4 5.7 3.4 109 5 98 165 1.8 0 1.8 1.6 11/12/2005 15:30:00 5.1 0.4 6.5 4.6 5.2 0.4 6.5 4.2 5 0.4 6.1 3.8 121 8 121 165 1.9 0 1.8 1.6 11/12/2005 15:40:00 5.1 0.5 6.8 4.2 5.2 0.5 6.8 3.8 5 0.5 7.2 3.8 127 6 119 165 1.8 0 1.8 1.6 11/12/2005 15:50:00 4.5 0.6 6.5 2.6 4.5 0.6 6.5 2.6 4.5 0.6 6.5 3 136 9 135 165 1.8 0 1.8 1.6 11/12/2005 16:00:00 3.6 0.4 4.6 2.3 3.7 0.4 4.6 2.6 3.6 0.4 4.6 2.3 118 8 111 165 1.9 0.1 2.1 1.6 11/12/2005 16:10:00 4 0.4 5.3 2.6 4.1 0.4 5.3 2.6 4 0.5 5.3 2.6 135 12 129 165 2.3 0.1 2.6 1.8 11/12/2005 16:20:00 3.3 0.4 4.6 2.3 3.3 0.4 4.6 2.3 3.2 0.5 4.2 1.9 129 11 147 165 2.4 0 2.6 2.3 11/12/2005 16:30:00 3.2 0.2 3.8 2.6 3.3 0.3 3.8 2.6 3.2 0.3 3.8 2.3 104 6 109 165 2 0.1 2.3 1.8 11/12/2005 16:40:00 3.2 0.3 4.2 2.6 3.3 0.3 4.2 2.6 3.2 0.3 3.8 2.3 105 3 106 165 1.8 0 1.8 1.6 11/12/2005 16:50:00 3.8 0.3 4.6 3 4 0.3 4.6 3 3.8 0.3 4.6 2.6 113 5 107 165 1.7 0 1.8 1.4 11/12/2005 17:00:00 4.1 0.2 4.6 3.4 4.2 0.3 4.6 3.4 4.2 0.3 4.6 3 100 3 98 165 1.6 0 1.6 1.4 11/12/2005 17:10:00 4.6 0.3 5.7 3.8 4.7 0.3 5.7 3.8 4.7 0.3 5.7 3.8 111 5 121 165 1.5 0.1 1.6 1.4 11/12/2005 17:20:00 4.4 0.3 4.9 3.8 4.5 0.3 4.9 3.8 4.4 0.3 5.3 3.8 119 3 116 165 1.4 0 1.6 1.4 11/12/2005 17:30:00 3.8 0.2 4.2 3.4 3.9 0.2 4.6 3.4 3.8 0.2 4.2 3.4 118 5 120 165 1.4 0 1.6 1.4 11/12/2005 17:40:00 4 0.2 4.6 3.4 4.1 0.2 4.6 3.4 4 0.2 4.6 3.4 113 3 110 165 1.4 0 1.6 1.1 11/12/2005 17:50:00 3.9 0.3 4.6 3.4 4 0.3 4.6 3.4 3.8 0.3 4.9 2.6 121 4 122 165 1.5 0 1.6 1.4 11/12/2005 18:00:00 3.8 0.2 4.6 3 3.9 0.2 4.6 3 3.7 0.3 4.2 2.6 121 4 126 165 1.6 0 1.6 1.4 11/12/2005 18:10:00 3.3 0.2 3.8 2.6 3.4 0.2 3.8 3 3.4 0.2 4.2 2.6 119 2 122 165 1.5 0 1.6 1.4 11/12/2005 18:20:00 3.1 0.2 3.8 2.6 3.2 0.3 3.8 2.6 3.1 0.3 3.8 2.3 122 2 122 165 1.6 0 1.6 1.4 11/12/2005 18:30:00 2.8 0.4 3.4 1.5 2.8 0.5 3.8 0.7 2.7 0.5 3.4 1.5 127 8 124 165 1.5 0 1.6 1.4 11/12/2005 18:40:00 2 0.3 3 1.1 2 0.4 3 1.1 2 0.3 3 1.1 139 8 124 165 1.4 0 1.6 1.4 11/12/2005 18:50:00 1.7 0.5 3 0.7 1.6 0.5 3 0.7 1.7 0.4 2.6 0.7 131 4 124 165 1.4 0 1.4 1.4 11/12/2005 19:00:00 0.8 0.4 1.9 0.4 0.7 0.4 1.5 0.4 0.9 0.3 1.5 0.4 150 19 132 165 1 0.1 1.4 0.9 11/12/2005 19:10:00 1 0.5 1.9 0.4 0.8 0.4 1.9 0.4 1 0.4 1.9 0.4 170 8 183 165 0.6 0 0.9 0.7 11/12/2005 19:20:00 0.8 0.5 1.9 0.4 0.7 0.4 1.5 0.4 0.8 0.4 1.5 0.4 180 0 183 165 0.8 0 1.1 0.7 11/12/2005 19:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0.1 0.7 0.4 180 0 165 165 1.1 0 1.4 0.9 11/12/2005 19:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 180 0 165 165 1 0 1.4 0.9 11/12/2005 19:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 180 0 165 165 1.2 0 1.4 1.1 11/12/2005 20:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 180 0 165 165 1.1 0 1.4 0.9 11/12/2005 20:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0.1 0.7 0.4 180 0 165 165 1.1 0 1.4 0.9 11/12/2005 20:20:00 0.6 0.4 1.5 0.4 0.6 0.3 1.5 0.4 0.8 0.4 1.5 0.4 228 36 280 165 0.9 0 1.1 0.9 11/12/2005 20:30:00 1.6 0.2 1.9 1.1 1.5 0.2 1.9 1.1 1.7 0.2 1.9 1.1 306 6 305 165 0.8 0 0.9 0.9 11/12/2005 20:40:00 1.6 0.2 2.3 1.1 1.6 0.3 2.3 1.1 1.5 0.2 1.9 1.1 309 0 309 165 0.8 0 0.9 0.7 11/12/2005 20:50:00 1.9 0.2 2.3 1.5 1.9 0.2 2.3 1.5 1.3 0.3 1.9 0.7 307 0 309 165 0.9 0 0.9 0.7 11/12/2005 21:00:00 1.9 0.2 2.3 1.5 1.9 0.2 2.3 1.5 1.5 0.3 2.3 0.7 304 4 307 165 0.9 0 1.1 0.7 11/12/2005 21:10:00 2.1 0.2 2.6 1.9 2.2 0.2 2.6 1.9 2.1 0.2 2.6 1.5 292 3 293 165 0.8 0 1.1 0.7 11/12/2005 21:20:00 2.2 0.2 2.6 1.9 2.1 0.2 2.6 1.9 1.8 0.4 2.6 1.1 295 9 300 165 0.9 0 0.9 0.7 11/12/2005 21:30:00 2.6 0.2 3 2.3 2.6 0.2 3 2.3 2.2 0.4 2.6 1.1 309 2 310 165 0.7 0 0.9 0.7 11/12/2005 21:40:00 2.2 0.3 2.6 1.5 2.2 0.3 2.6 1.5 1.7 0.3 2.3 0.7 306 0 306 165 0.8 0 0.9 0.7 11/12/2005 21:50:00 1.4 0.4 2.3 0.7 1.3 0.4 2.3 0.7 1.4 0.3 1.9 0.7 318 6 306 165 0.8 0 0.9 0.7 11/12/2005 22:00:00 0.4 0.1 1.1 0.4 0.4 0.2 1.1 0.4 0.6 0.2 1.1 0.4 322 0 322 165 0.8 0 0.9 0.7 11/12/2005 22:10:00 0.9 0.2 1.5 0.4 0.9 0.2 1.5 0.4 1 0.2 1.5 0.7 322 0 322 165 0.8 0 0.9 0.7 11/12/2005 22:20:00 1.6 0.5 2.3 0.4 1.5 0.5 2.3 0.4 1.2 0.4 1.9 0.4 309 8 305 165 0.8 0 0.9 0.9 11/12/2005 22:30:00 2.2 0.3 2.6 1.5 2.2 0.3 2.6 1.1 1.8 0.4 2.6 0.7 293 8 302 165 0.8 0 0.9 0.7 11/12/2005 22:40:00 2.5 0.4 3.4 1.5 2.5 0.5 3.4 1.5 1.9 0.4 3 1.1 299 5 307 165 0.7 0 0.9 0.7 11/12/2005 22:50:00 2.8 0.3 3.4 1.9 2.8 0.3 3.4 1.9 1.9 0.3 2.6 1.1 300 4 300 165 0.5 0 0.7 0.2 11/12/2005 23:00:00 2.9 0.4 4.2 2.3 3 0.3 3.8 2.3 2.3 0.5 3.4 1.5 304 5 316 165 0.7 0 0.9 0.2 11/12/2005 23:10:00 2.5 0.3 3 1.9 2.5 0.3 3 1.9 1.7 0.3 2.3 1.1 295 3 296 165 0.7 0 0.9 0.4 11/12/2005 23:20:00 2.9 0.4 3.8 1.9 3 0.4 4.2 1.9 2.7 0.5 3.8 1.5 285 5 282 165 0.5 0.1 0.7 0.2 11/12/2005 23:30:00 3.3 0.4 4.2 2.3 3.4 0.4 4.6 2.3 3.1 0.5 4.2 1.5 287 4 294 165 0.4 0 0.7 0.2 11/12/2005 23:40:00 3.4 0.4 4.2 2.6 3.5 0.4 4.2 2.6 3.1 0.6 4.2 1.9 287 6 288 165 0.4 0 0.7 0.2 11/12/2005 23:50:00 2.8 0.5 3.8 1.5 2.9 0.5 3.8 1.5 2.7 0.6 4.2 1.5 284 12 295 165 0.6 0 0.9 0.2 11/13/2005 00:00:00 2.8 0.4 3.4 1.5 2.8 0.5 3.4 1.5 2.5 0.4 3.4 1.5 312 14 293 165 0.4 0.1 0.7 0.2 11/13/2005 00:10:00 1.7 0.6 3 0.4 1.7 0.6 2.6 0.4 1.7 0.6 2.6 0.7 322 10 319 165 0.4 0 0.7 -0.1 11/13/2005 00:20:00 0.5 0.3 1.1 0.4 0.5 0.2 1.1 0.4 0.5 0.3 1.1 0.4 312 0 312 165 0.5 0 0.7 0.4 11/13/2005 00:30:00 1.1 0.6 2.3 0.4 0.7 0.4 2.3 0.4 1 0.5 2.3 0.4 14 20 353 165 0.5 0 0.7 0.2 11/13/2005 00:40:00 1.9 0.5 3 0.7 1.5 0.4 2.3 0.4 1.8 0.5 3 0.4 343 21 1 165 0.4 0 0.7 0.2 11/13/2005 00:50:00 1.3 0.5 2.6 0.4 1.1 0.4 2.3 0.4 1.2 0.6 2.6 0.4 36 22 351 165 0.7 0.1 0.9 0.4 11/13/2005 01:00:00 0.6 0.4 1.9 0.4 0.5 0.3 1.9 0.4 0.6 0.4 1.9 0.4 41 56 341 165 0.7 0 0.9 0.4 11/13/2005 01:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 45 0 165 165 0.8 0 0.9 0.7 11/13/2005 01:20:00 0.6 0.5 2.3 0.4 0.6 0.4 1.9 0.4 0.8 0.5 2.3 0.4 355 53 300 165 0.5 0 0.9 0.4 11/13/2005 01:30:00 1 0.5 1.9 0.4 1 0.5 1.9 0.4 1.2 0.4 1.9 0.4 277 7 274 165 0.5 0 0.7 0.4 11/13/2005 01:40:00 0.9 0.4 1.9 0.4 0.8 0.3 1.9 0.4 0.9 0.5 1.9 0.4 316 29 349 165 0.8 0 0.9 0.7 11/13/2005 01:50:00 1.5 0.6 2.3 0.4 1.3 0.6 2.3 0.4 1.3 0.6 2.3 0.4 340 14 340 165 0.7 0 0.9 0.7 11/13/2005 02:00:00 2.3 0.8 3.8 0.7 2.1 1 4.2 0.4 2.1 0.9 4.2 0.4 313 26 284 165 0.7 0 0.9 0.4 11/13/2005 02:10:00 2.5 0.3 3.4 1.5 2.5 0.3 3.4 1.5 2.4 0.4 3 1.5 292 7 286 165 0.5 0 0.7 0.2 11/13/2005 02:20:00 2.2 0.5 3.4 1.1 2.2 0.6 3.4 0.7 2.3 0.5 3.4 1.1 286 6 295 165 0.7 0.2 1.1 0.2 11/13/2005 02:30:00 2.7 0.4 3.8 1.9 2.7 0.4 3.8 1.5 2.2 0.4 3.4 1.1 293 5 294 165 0.8 0 0.9 0.7 11/13/2005 02:40:00 1.7 0.4 2.6 0.7 1.6 0.4 2.6 0.7 1.3 0.5 2.6 0.4 294 4 294 165 0.8 0 0.9 0.7 11/13/2005 02:50:00 0.7 0.4 1.9 0.4 0.7 0.4 1.5 0.4 0.8 0.4 1.5 0.4 295 9 292 165 1.1 0 1.4 0.9 11/13/2005 03:00:00 0.4 0.1 1.1 0.4 0.4 0.1 1.1 0.4 0.6 0.3 1.5 0.4 300 5 304 165 1.2 0 1.4 1.1 11/13/2005 03:10:00 0.4 0.1 0.7 0.4 0.4 0 0.4 0.4 0.4 0.1 0.7 0.4 294 0 294 165 1.1 0 1.4 0.9 11/13/2005 03:20:00 0.4 0.1 0.7 0.4 0.4 0 0.4 0.4 0.5 0.2 1.1 0.4 294 0 294 165 1.2 0.1 1.4 0.9 11/13/2005 03:30:00 0.5 0.2 1.1 0.4 0.5 0.2 1.1 0.4 0.9 0.3 1.5 0.4 294 0 295 165 1.2 0 1.4 1.1 11/13/2005 03:40:00 0.7 0.4 1.5 0.4 0.7 0.3 1.5 0.4 1 0.2 1.9 0.4 282 15 256 165 1.2 0 1.4 1.1 11/13/2005 03:50:00 1.1 0.7 2.3 0.4 1.1 0.7 2.6 0.4 1.5 0.6 2.6 0.4 259 3 265 165 1.4 0 1.6 1.4 11/13/2005 04:00:00 2 0.2 2.6 1.5 2 0.3 2.6 1.5 1.7 0.4 2.6 0.7 278 9 264 165 1.3 0 1.6 1.1 11/13/2005 04:10:00 2.2 0.4 3 1.5 2.2 0.4 3 1.5 1.6 0.4 3 0.7 296 3 300 165 0.9 0 1.1 0.9 11/13/2005 04:20:00 2.7 0.3 3.4 1.9 2.7 0.3 3.4 1.9 2.2 0.4 3.4 1.1 292 4 293 165 0.9 0 1.1 0.7 11/13/2005 04:30:00 1.7 0.3 2.6 0.7 1.7 0.3 2.6 1.1 1.6 0.3 2.6 0.7 278 9 290 165 1.2 0.2 1.6 0.7 11/13/2005 04:40:00 0.6 0.5 2.3 0.4 0.6 0.4 1.9 0.4 0.7 0.4 1.9 0.4 284 0 284 165 1.4 0 1.6 1.4 11/13/2005 04:50:00 0.5 0.2 1.1 0.4 0.5 0.2 1.5 0.4 0.5 0.2 1.1 0.4 280 4 280 165 1.4 0 1.6 1.4 11/13/2005 05:00:00 0.8 0.4 1.9 0.4 0.8 0.4 1.9 0.4 1.1 0.3 1.9 0.4 258 1 262 165 1.4 0.1 1.6 1.1 11/13/2005 05:10:00 1.1 0.4 1.9 0.4 1 0.4 1.9 0.4 0.8 0.3 1.9 0.4 293 15 272 165 1.5 0.1 1.6 1.4 11/13/2005 05:20:00 0.9 0.6 2.3 0.4 0.9 0.6 2.3 0.4 0.8 0.5 1.9 0.4 313 7 310 165 1.3 0 1.4 1.1 11/13/2005 05:30:00 1.6 0.5 2.6 0.4 1.4 0.6 2.6 0.4 1.2 0.5 2.6 0.4 302 15 316 165 0.9 0.1 1.4 0.7 11/13/2005 05:40:00 0.7 0.4 1.9 0.4 0.7 0.4 1.9 0.4 0.5 0.2 1.1 0.4 286 17 267 165 0.4 0.1 0.7 0.2 11/13/2005 05:50:00 0.8 0.5 1.9 0.4 0.7 0.4 1.9 0.4 0.7 0.4 1.5 0.4 327 8 310 165 0.4 0 0.7 0.2 11/13/2005 06:00:00 0.9 0.3 1.5 0.4 0.8 0.3 1.5 0.4 0.9 0.3 1.5 0.4 13 35 4 165 0.3 0 0.7 0.2 11/13/2005 06:10:00 0.6 0.4 1.5 0.4 0.6 0.4 1.5 0.4 0.5 0.3 1.1 0.4 97 4 84 165 0.5 0.1 0.9 0.2 11/13/2005 06:20:00 0.6 0.3 1.5 0.4 0.5 0.3 1.5 0.4 0.8 0.3 1.5 0.4 7 35 347 165 0.4 0.2 0.9 0.2 11/13/2005 06:30:00 0.6 0.4 1.5 0.4 0.6 0.3 1.5 0.4 0.9 0.3 1.5 0.4 346 0 347 165 0.7 0 0.9 0.7 11/13/2005 06:40:00 0.4 0.1 1.5 0.4 0.4 0.1 1.5 0.4 0.5 0.3 1.9 0.4 344 10 282 165 0.8 0 0.9 0.7 11/13/2005 06:50:00 1.3 0.7 3 0.4 1.4 0.8 3.8 0.4 1.7 0.7 3.8 0.7 263 10 273 165 0.9 0 1.1 0.9 11/13/2005 07:00:00 2.8 0.9 4.6 0.7 2.8 0.9 4.6 0.7 2.7 0.8 4.2 0.4 278 20 289 165 0.7 0.1 0.9 0.2 11/13/2005 07:10:00 4.5 0.5 5.7 3.4 4.5 0.5 5.7 3.4 3.8 0.6 5.7 2.6 303 7 297 165 0.2 0 0.4 0.2 11/13/2005 07:20:00 5.1 0.5 6.8 3.8 5.1 0.5 6.8 3.4 3.9 0.5 5.3 2.6 301 6 296 165 0 0 0.2 -0.1 11/13/2005 07:30:00 4.6 0.5 5.7 3 4.7 0.5 5.7 3.4 3.8 0.6 5.7 2.3 297 6 296 165 0.1 0.1 0.4 -0.3 11/13/2005 07:40:00 4.5 0.5 5.7 3 4.5 0.5 5.7 3 3.6 0.7 5.7 2.3 300 7 295 165 0.5 0 0.7 0.2 11/13/2005 07:50:00 4.9 0.4 5.7 4.2 4.9 0.4 6.1 3.8 4.3 0.6 5.7 2.6 308 7 298 165 0.5 0.1 0.7 0.2 11/13/2005 08:00:00 4.1 0.5 5.3 3.4 4.2 0.5 5.3 3 3.1 0.4 4.2 2.3 299 4 302 165 0.4 0 0.7 0.2 11/13/2005 08:10:00 4.4 0.4 5.3 3.4 4.5 0.4 5.3 3.4 3.6 0.6 4.9 2.3 291 5 291 165 0.5 0 0.7 0.2 11/13/2005 08:20:00 4.2 0.4 5.3 2.6 4.2 0.4 5.3 2.6 4.1 0.6 5.3 2.3 284 5 280 165 0.5 0 0.7 0.2 11/13/2005 08:30:00 4.7 0.5 5.7 3.4 4.7 0.5 6.1 3.4 4.3 0.5 5.3 3 287 8 292 165 0.5 0 0.7 0.2 11/13/2005 08:40:00 4.7 0.4 5.3 3.4 4.7 0.4 5.7 3.8 4.3 0.5 5.3 2.6 289 5 289 165 0.4 0 0.7 0.2 11/13/2005 08:50:00 4 0.4 4.9 3.4 4 0.4 4.9 3.4 3.8 0.4 4.9 2.6 289 4 293 165 0.7 0.2 0.9 0.2 11/13/2005 09:00:00 3.6 0.3 4.2 2.6 3.7 0.3 4.2 2.6 3.4 0.4 4.2 2.3 289 4 295 165 1 0 1.4 0.9 11/13/2005 09:10:00 3.1 0.3 3.8 1.9 3.2 0.3 3.8 2.3 3.3 0.3 4.2 2.6 277 6 289 165 1.2 0.1 1.6 0.9 11/13/2005 09:20:00 3.1 0.4 3.8 2.3 3.1 0.4 3.8 1.9 3.1 0.5 3.8 1.5 282 5 281 165 1.4 0 1.6 1.4 11/13/2005 09:30:00 2.6 0.4 3.4 1.9 2.6 0.4 3.4 1.9 2.6 0.5 3.4 1.5 284 4 282 165 1.5 0 1.6 1.4 11/13/2005 09:40:00 2.3 0.3 3 1.5 2.4 0.3 3 1.9 2.4 0.3 3 1.5 271 9 268 165 1.8 0.1 2.1 1.4 11/13/2005 09:50:00 2 0.3 2.6 1.1 2.1 0.3 2.6 1.5 2.2 0.2 2.6 1.5 250 15 266 165 2.1 0 2.6 1.8 11/13/2005 10:00:00 1.9 0.4 2.6 0.7 2 0.3 2.6 1.5 2.1 0.3 2.6 1.5 247 9 254 165 2.5 0.1 2.8 2.3 11/13/2005 10:10:00 1.4 0.4 2.6 0.4 1.5 0.4 2.6 0.4 1.6 0.4 2.3 0.7 247 8 256 165 2.8 0.1 3 2.3 11/13/2005 10:20:00 1.3 0.5 2.3 0.4 1.5 0.5 2.3 0.4 1.6 0.5 2.3 0.4 254 8 245 165 3 0 3.3 2.8 11/13/2005 10:30:00 0.6 0.3 1.5 0.4 0.7 0.3 1.5 0.4 0.8 0.3 1.5 0.4 272 5 258 165 3.5 0.2 3.8 3 11/13/2005 10:40:00 1 0.4 1.9 0.4 1 0.4 1.9 0.4 0.9 0.3 1.5 0.4 281 12 297 165 3.8 0 4.3 3.5 11/13/2005 10:50:00 0.7 0.4 1.9 0.4 0.6 0.4 1.5 0.4 0.6 0.3 1.5 0.4 287 9 298 165 4.6 0.3 5.2 4.3 11/13/2005 11:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0.1 0.7 0.4 278 0 165 165 6.4 1 8 5 11/13/2005 11:10:00 0.4 0 0.7 0.4 0.4 0 0.7 0.4 0.4 0.1 0.7 0.4 278 0 278 165 7.7 0.5 8.8 7 11/13/2005 11:20:00 0.5 0.3 1.5 0.4 0.4 0.2 1.5 0.4 0.5 0.3 1.9 0.4 157 47 169 165 7.3 1 8.8 6 11/13/2005 11:30:00 0.9 0.4 1.9 0.4 0.7 0.4 1.5 0.4 1.1 0.5 2.3 0.4 155 16 170 165 5.2 0.6 6.2 4.3 11/13/2005 11:40:00 1.4 0.3 2.3 0.7 1.3 0.4 2.3 0.4 1.5 0.3 2.3 0.7 154 7 162 165 3.7 0.2 4.3 3 11/13/2005 11:50:00 1.5 0.3 2.3 0.7 1.4 0.3 2.3 0.7 1.6 0.3 2.3 0.7 149 13 153 165 3.8 0 4 3.5 11/13/2005 12:00:00 1.3 0.3 2.3 0.7 1.2 0.3 2.3 0.4 1.4 0.4 2.3 0.7 163 9 159 165 4.1 0 4.3 3.8 11/13/2005 12:10:00 0.6 0.3 1.9 0.4 0.5 0.3 1.5 0.4 0.6 0.4 1.9 0.4 194 56 144 165 4.3 0.7 6 3.5 11/13/2005 12:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0.1 0.7 0.4 294 0 165 165 7.7 0.8 8.8 6 11/13/2005 12:30:00 0.4 0.1 1.1 0.4 0.4 0.1 0.7 0.4 0.5 0.2 1.1 0.4 294 0 294 165 9 0.2 9.3 8.3 11/13/2005 12:40:00 0.4 0.1 1.1 0.4 0.4 0.1 1.1 0.4 0.4 0 0.7 0.4 294 0 294 165 7.4 1 9.3 5.7 11/13/2005 12:50:00 1.1 0.7 2.3 0.4 0.8 0.5 1.9 0.4 1.3 0.7 2.3 0.4 350 64 357 165 6.4 0.3 7 5.7 11/13/2005 13:00:00 1.6 0.7 3.4 0.4 1.1 0.8 3.8 0.4 1.8 0.7 3.8 0.7 17 61 150 165 5.9 0.6 6.7 4.3 11/13/2005 13:10:00 1.5 0.7 3 0.4 1.4 0.7 3 0.4 1.7 0.7 3 0.4 155 14 166 165 3.6 0.3 4.5 3.3 11/13/2005 13:20:00 2.1 0.6 3.4 0.4 2 0.6 3.4 0.4 2.2 0.4 3 0.7 156 9 155 165 3.2 0.2 3.8 2.8 11/13/2005 13:30:00 2.3 0.5 3.4 1.1 2.2 0.5 3.8 1.1 2.4 0.4 3.4 1.5 151 10 171 165 3 0.1 3.3 2.6 11/13/2005 13:40:00 2.2 0.4 3.4 1.1 2.1 0.4 3 1.1 2.2 0.3 3 1.1 154 13 162 165 3 0.2 3.3 2.6 11/13/2005 13:50:00 1.4 0.4 2.3 0.4 1.3 0.4 2.3 0.4 1.4 0.4 2.3 0.7 140 9 158 165 3.3 0.3 3.8 2.8 11/13/2005 14:00:00 1.7 0.6 3 0.4 1.6 0.6 3 0.4 1.9 0.5 3 0.7 154 9 156 165 3.4 0.2 3.8 2.8 11/13/2005 14:10:00 1.2 0.4 1.9 0.4 1.1 0.4 1.9 0.4 1.3 0.3 1.9 0.4 153 8 164 165 3.5 0.1 3.8 3 11/13/2005 14:20:00 2 0.4 3 1.1 1.9 0.4 3 1.1 2.1 0.4 3 1.1 158 7 164 165 3.3 0.2 3.8 2.6 11/13/2005 14:30:00 1.7 0.4 2.6 1.1 1.6 0.4 2.6 0.7 1.8 0.4 3 1.1 152 14 159 165 3 0.2 3.3 2.6 11/13/2005 14:40:00 1.4 0.5 2.6 0.7 1.3 0.5 2.6 0.7 1.5 0.5 2.6 0.7 154 8 160 165 3.2 0 3.3 2.6 11/13/2005 14:50:00 1.7 0.4 2.3 0.7 1.6 0.3 2.3 0.7 1.7 0.4 2.6 0.7 158 4 154 165 3.1 0 3.3 3 11/13/2005 15:00:00 1.1 0.5 2.6 0.4 1 0.5 3 0.4 1.2 0.5 3 0.4 141 15 164 165 3.4 0.2 3.8 3 11/13/2005 15:10:00 1.9 0.4 3 1.1 1.8 0.4 3 1.1 2 0.4 3 1.1 156 7 164 165 3.1 0.1 3.5 2.8 11/13/2005 15:20:00 2 0.3 2.6 1.5 1.9 0.3 2.6 1.1 2.1 0.4 3 1.1 153 6 148 165 2.8 0 3 2.6 11/13/2005 15:30:00 2.5 0.2 3 1.9 2.4 0.2 3 1.9 2.5 0.3 3 1.9 148 5 150 165 2.5 0 2.6 2.3 11/13/2005 15:40:00 2.8 0.2 3.4 2.3 2.7 0.2 3.4 2.3 2.9 0.3 3.4 2.3 156 3 162 165 2.3 0 2.6 2.1 11/13/2005 15:50:00 2.5 0.2 3 2.3 2.3 0.2 3 1.9 2.5 0.2 3 1.9 154 2 153 165 2.1 0 2.3 2.1 11/13/2005 16:00:00 1.8 0.3 2.6 1.1 1.7 0.3 2.3 1.1 1.7 0.3 2.6 1.1 156 4 155 165 2.1 0 2.6 1.8 11/13/2005 16:10:00 1.6 0.4 2.3 0.7 1.5 0.4 2.3 0.7 1.5 0.4 2.3 0.7 155 5 155 165 2.1 0 2.3 1.8 11/13/2005 16:20:00 1.2 0.4 1.9 0.4 1.1 0.4 1.9 0.4 1.1 0.4 1.9 0.4 143 0 143 165 2.1 0.1 2.3 1.8 11/13/2005 16:30:00 1.5 0.3 1.9 0.7 1.4 0.3 1.9 0.7 1.4 0.3 2.3 0.7 145 1 143 165 1.7 0.2 1.8 1.1 11/13/2005 16:40:00 1.1 0.3 1.9 0.4 1 0.3 1.9 0.4 1 0.3 1.5 0.4 145 1 145 165 0.7 0.2 1.1 0.2 11/13/2005 16:50:00 2 0.5 2.6 1.1 1.9 0.5 2.6 1.1 1.9 0.5 2.6 0.7 155 6 162 165 0.5 0.2 0.9 0.2 11/13/2005 17:00:00 2.5 0.3 3 1.9 2.3 0.3 3 1.5 2.4 0.3 3 1.5 161 4 162 165 0.8 0 1.1 0.4 11/13/2005 17:10:00 2.6 0.3 3 1.9 2.4 0.3 3 1.9 2.4 0.2 3 1.9 162 3 158 165 0.8 0 0.9 0.7 11/13/2005 17:20:00 2.1 0.4 3 1.5 1.9 0.4 2.6 1.1 1.9 0.3 2.6 1.1 155 6 162 165 0.8 0 0.9 0.7 11/13/2005 17:30:00 1.6 0.4 2.3 0.4 1.5 0.4 2.3 0.4 1.4 0.4 2.3 0.4 151 8 146 165 0.8 0 0.9 0.7 11/13/2005 17:40:00 1.1 0.3 1.9 0.4 1 0.4 1.5 0.4 1 0.4 1.9 0.4 141 6 149 165 0.6 0 0.7 0.2 11/13/2005 17:50:00 1.2 0.5 1.9 0.4 1 0.5 1.9 0.4 0.9 0.5 1.9 0.4 138 7 148 165 0.5 0 0.7 0.2 11/13/2005 18:00:00 0.8 0.3 1.9 0.4 0.7 0.3 1.5 0.4 0.6 0.3 1.1 0.4 136 0 136 165 0.2 0 0.4 0.2 11/13/2005 18:10:00 1 0.4 1.5 0.4 0.9 0.4 1.5 0.4 1 0.3 1.5 0.4 137 0 136 165 0.1 0 0.2 -0.1 11/13/2005 18:20:00 1.2 0.2 1.5 0.7 1.1 0.2 1.5 0.7 1.1 0.2 1.5 0.4 137 0 136 165 0.1 0 0.2 -0.1 11/13/2005 18:30:00 0.9 0.2 1.1 0.4 0.8 0.2 1.1 0.4 0.7 0.2 1.1 0.4 137 0 137 165 0.1 0 0.4 0.2 11/13/2005 18:40:00 1.1 0.2 1.5 0.7 1 0.2 1.5 0.7 1.1 0.2 1.5 0.7 131 5 126 165 0.4 0 0.7 0.2 11/13/2005 18:50:00 1.3 0.2 1.9 0.7 1.3 0.2 1.9 0.7 1.3 0.2 1.9 0.7 118 2 117 165 0.5 0 0.9 0.2 11/13/2005 19:00:00 1.2 0.4 1.9 0.7 1.2 0.4 1.9 0.7 1.1 0.4 1.9 0.4 108 4 103 165 0.8 0.1 0.9 0.4 11/13/2005 19:10:00 2.1 0.3 3 1.1 2 0.3 3 0.7 2 0.4 2.6 1.1 114 12 107 165 0.9 0 1.4 0.7 11/13/2005 19:20:00 2.1 0.4 2.6 1.1 2.1 0.4 2.6 1.1 2.1 0.4 3 1.1 108 6 106 165 1 0 1.1 0.9 11/13/2005 19:30:00 2.1 0.3 3 1.5 2.1 0.3 3 1.5 2 0.3 2.6 1.5 106 5 105 165 0.9 0 0.9 0.7 11/13/2005 19:40:00 2.9 0.3 3.4 2.3 3 0.3 3.4 1.9 2.9 0.4 3.4 1.9 92 5 89 165 0.9 0 1.1 0.9 11/13/2005 19:50:00 3.1 0.2 3.4 2.6 3.2 0.2 3.4 2.6 3.1 0.2 3.4 2.6 92 0 91 165 0.9 0 1.1 0.7 11/13/2005 20:00:00 2.9 0.2 3.4 2.6 3 0.2 3.4 2.6 2.9 0.2 3.4 2.6 94 5 99 165 0.8 0 0.9 0.7 11/13/2005 20:10:00 3 0.2 3.4 2.6 3.1 0.2 3.4 2.6 3 0.2 3.4 2.6 93 5 98 165 0.9 0 1.1 0.9 11/13/2005 20:20:00 3.1 0.4 4.2 2.6 3.2 0.4 4.2 2.6 3.1 0.4 3.8 2.6 82 5 81 165 0.8 0 0.9 0.7 11/13/2005 20:30:00 3.2 0.2 4.2 2.6 3.3 0.2 4.2 2.6 3.2 0.3 4.2 2.6 79 11 88 165 0.9 0 1.1 0.7 11/13/2005 20:40:00 3.1 0.3 3.8 1.9 3.2 0.3 3.8 2.3 3.2 0.2 3.4 2.6 68 4 71 165 0.9 0 0.9 0.7 11/13/2005 20:50:00 3 0.3 3.8 1.9 3 0.3 3.8 1.9 3 0.3 4.2 2.3 47 11 53 165 0.8 0 0.9 0.7 11/13/2005 21:00:00 3 0.3 3.8 2.6 3 0.3 3.8 2.3 3.1 0.3 3.8 2.6 32 3 34 165 0.6 0 0.9 0.7 11/13/2005 21:10:00 3.4 0.3 3.8 2.6 3.4 0.3 3.8 2.6 3.4 0.3 4.2 2.6 34 4 29 165 0.4 0.1 0.7 0.2 11/13/2005 21:20:00 3.3 0.3 3.8 2.3 3.4 0.3 3.8 2.3 3.3 0.3 3.8 2.6 52 10 43 165 0.2 0 0.4 0.2 11/13/2005 21:30:00 3 0.3 3.4 2.3 3.1 0.3 3.8 2.3 3 0.3 3.8 2.3 64 6 57 165 0.5 0 0.7 0.2 11/13/2005 21:40:00 2.8 0.3 4.2 2.3 2.9 0.3 3.8 2.3 2.9 0.4 3.8 2.3 81 10 75 165 0.8 0.1 0.9 0.2 11/13/2005 21:50:00 3.1 0.5 4.6 1.9 3.2 0.5 4.6 1.9 3.1 0.5 4.6 2.3 82 8 81 165 1 0 1.4 0.9 11/13/2005 22:00:00 3.2 0.4 4.2 2.3 3.2 0.4 4.2 2.3 3 0.5 4.2 1.9 100 18 74 165 1.1 0 1.4 0.9 11/13/2005 22:10:00 3 0.3 3.4 2.3 3 0.3 3.8 2.3 2.9 0.3 3.4 1.9 113 6 111 165 1.2 0 1.4 0.9 11/13/2005 22:20:00 2.8 0.4 3.8 1.9 2.8 0.4 3.8 1.9 2.8 0.4 3.4 1.9 87 9 81 165 1.2 0 1.4 0.9 11/13/2005 22:30:00 3 0.5 5.3 1.9 3.1 0.5 4.9 1.9 3.1 0.5 4.9 1.9 88 9 79 165 1.2 0 1.4 0.9 11/13/2005 22:40:00 3.5 0.4 4.9 2.6 3.5 0.4 4.9 2.6 3.4 0.4 4.6 2.6 104 10 94 165 1.4 0.1 1.6 1.1 11/13/2005 22:50:00 2.7 0.5 3.8 1.5 2.8 0.5 3.8 1.5 2.8 0.4 3.8 1.9 79 11 64 165 1.4 0 1.6 1.4 11/13/2005 23:00:00 3.3 0.4 4.6 2.3 3.3 0.4 4.6 2.3 3.3 0.4 4.6 2.3 93 10 102 165 1.4 0 1.6 1.1 11/13/2005 23:10:00 3.5 0.5 4.6 1.9 3.6 0.5 4.9 2.3 3.5 0.5 4.6 2.3 99 10 105 165 1.7 0 1.8 1.4 11/13/2005 23:20:00 3.4 0.4 4.6 2.3 3.4 0.4 4.9 2.3 3.2 0.4 4.2 2.3 97 8 111 165 1.7 0 1.8 1.4 11/13/2005 23:30:00 4 1 7.6 1.9 4.1 1.1 7.6 1.9 3.9 1.1 6.8 1.5 93 15 89 165 1.8 0 1.8 1.4 11/13/2005 23:40:00 3.3 0.3 3.8 2.6 3.3 0.4 3.8 2.3 3.3 0.3 3.8 2.6 41 5 39 165 1.4 0.1 1.8 1.4 11/13/2005 23:50:00 3.4 0.4 4.6 2.6 3.5 0.5 4.6 2.6 3.4 0.4 4.2 2.6 50 8 58 165 1.2 0 1.4 1.1 11/14/2005 00:00:00 3.8 0.5 4.9 2.6 3.9 0.5 5.3 2.6 3.7 0.5 4.9 2.6 63 11 65 165 1.3 0 1.4 1.1 11/14/2005 00:10:00 3.6 0.2 4.2 3.4 3.7 0.2 4.2 3 3.6 0.2 4.2 3 47 4 57 165 1.2 0 1.4 1.1 11/14/2005 00:20:00 3.5 0.2 4.2 3 3.6 0.2 4.2 3 3.5 0.2 4.2 3 48 4 46 165 1.1 0 1.4 0.9 11/14/2005 00:30:00 4.1 0.4 5.3 3 4.1 0.4 5.3 3 4.1 0.4 4.9 3 38 5 34 165 1.1 0 1.4 0.9 11/14/2005 00:40:00 4.9 0.3 5.7 3.8 4.9 0.3 5.7 3.8 4.9 0.4 5.7 3.8 36 3 33 165 1.1 0 1.1 0.9 11/14/2005 00:50:00 4.8 0.4 5.7 3.8 4.9 0.4 5.7 3.8 4.8 0.5 5.7 3.4 35 4 28 165 1 0 1.1 0.9 11/14/2005 01:00:00 4.6 0.4 5.7 3.8 4.7 0.4 5.7 3.8 4.5 0.5 6.1 3.4 42 3 39 165 1.1 0 1.1 0.9 11/14/2005 01:10:00 4.6 0.4 5.3 3.4 4.6 0.4 5.7 3.8 4.5 0.6 5.7 3 43 5 42 165 1.1 0 1.1 0.9 11/14/2005 01:20:00 4.8 0.8 6.5 2.6 4.9 0.8 6.5 2.6 4.4 0.7 6.1 2.3 56 8 50 165 1.1 0 1.4 0.9 11/14/2005 01:30:00 4.9 0.6 6.5 3.4 5.1 0.6 6.5 3 4.7 0.6 6.1 3 65 6 61 165 1.2 0 1.4 0.9 11/14/2005 01:40:00 5.5 0.9 7.6 3.4 5.6 1 7.6 3.4 5.3 1 7.2 3 56 7 49 165 1.2 0 1.4 0.9 11/14/2005 01:50:00 5.5 0.5 6.8 3.8 5.6 0.5 6.8 4.2 5.2 0.6 6.5 3.8 59 5 57 165 1.1 0 1.4 0.9 11/14/2005 02:00:00 5.3 0.5 6.5 3.8 5.4 0.5 6.8 4.2 4.9 0.5 6.1 3.8 63 7 60 165 0.9 0 1.1 0.9 11/14/2005 02:10:00 5.6 0.5 6.5 3.8 5.7 0.5 6.8 3.8 5.3 0.6 6.8 3.8 47 6 46 165 0.9 0 1.1 0.9 11/14/2005 02:20:00 5.6 0.5 6.5 4.2 5.8 0.5 6.8 4.6 5.3 0.5 6.5 3.4 61 5 62 165 0.8 0 0.9 0.7 11/14/2005 02:30:00 5.6 0.9 7.2 3.4 5.6 0.9 7.6 3 5.3 1.1 7.2 2.6 42 7 43 165 0.8 0 0.9 0.7 11/14/2005 02:40:00 6.3 0.6 8 4.6 6.3 0.6 8 4.6 6 0.6 8 3.8 41 5 43 165 0.8 0 0.9 0.7 11/14/2005 02:50:00 6.5 0.4 7.2 4.6 6.5 0.4 7.6 4.6 6 0.6 7.6 4.2 43 6 50 165 0.8 0 0.9 0.7 11/14/2005 03:00:00 6.5 0.4 8 5.3 6.5 0.4 7.6 4.9 6.2 0.6 8 4.2 39 4 34 165 0.8 0 0.9 0.7 11/14/2005 03:10:00 6.7 0.6 8 4.2 6.7 0.6 8 4.2 6.4 0.7 8.4 4.2 40 5 39 165 0.8 0 0.9 0.7 11/14/2005 03:20:00 5.1 0.6 6.5 3.8 5.1 0.6 6.5 3.4 4.9 0.6 6.8 3.4 36 6 40 165 0.8 0 0.9 0.7 11/14/2005 03:30:00 5.2 0.4 6.5 4.2 5.2 0.4 6.5 4.2 5.2 0.5 6.5 3.4 32 5 25 165 0.8 0 0.9 0.7 11/14/2005 03:40:00 5.7 0.4 6.8 4.9 5.7 0.4 6.8 4.6 5.8 0.4 6.5 4.9 30 4 29 165 0.8 0 0.9 0.7 11/14/2005 03:50:00 5.7 0.5 6.8 4.2 5.6 0.6 6.8 4.2 5.7 0.6 7.2 3.8 27 5 25 165 0.8 0 0.9 0.7 11/14/2005 04:00:00 6.7 0.6 8.8 4.9 6.6 0.7 8.4 4.6 6.6 0.7 8.8 4.9 26 5 22 165 0.8 0 0.9 0.7 11/14/2005 04:10:00 6.7 0.6 8 4.9 6.6 0.7 8 4.2 6.6 0.8 8 4.2 26 5 30 165 0.8 0 0.9 0.7 11/14/2005 04:20:00 7 0.5 8 5.7 7 0.5 8 5.7 6.9 0.5 8 5.3 28 3 25 165 0.9 0 1.1 0.7 11/14/2005 04:30:00 7 0.5 8.8 5.7 7 0.6 8.8 5.7 6.7 0.6 8.4 4.9 33 4 34 165 1.1 0 1.4 0.9 11/14/2005 04:40:00 8.7 0.8 9.9 6.1 8.7 0.8 10.3 6.1 8.1 0.9 10.3 5.7 40 6 35 165 1.4 0.1 1.6 0.9 11/14/2005 04:50:00 8.3 0.9 10.7 5.7 8.4 0.9 10.7 5.7 8 0.8 10.7 5.7 40 7 50 165 1.6 0 1.8 1.4 11/14/2005 05:00:00 6.8 0.8 9.1 4.9 6.8 0.8 9.1 4.9 6.6 0.8 8.4 4.9 40 6 56 165 1.4 0 1.6 1.4 11/14/2005 05:10:00 8 1 10.7 5.7 8 1 10.7 5.3 7.5 1.1 9.9 4.9 44 7 44 165 1.6 0.1 1.8 1.1 11/14/2005 05:20:00 9 0.9 11.5 6.5 9.1 1 11.5 6.5 8.5 0.9 10.7 5.7 43 6 46 165 1.9 0 1.8 1.6 11/14/2005 05:30:00 9.4 1 11.8 6.5 9.5 1 11.8 6.5 9 1 11.8 6.1 41 6 43 165 1.9 0 1.8 1.6 11/14/2005 05:40:00 9.4 1 11.5 6.5 9.5 1 11.8 6.1 8.9 1.1 11.8 6.1 44 6 47 165 1.9 0 2.1 1.8 11/14/2005 05:50:00 9.7 0.8 11.8 7.6 9.7 0.9 12.2 7.6 9.2 1 12.6 6.1 43 6 50 165 1.9 0 2.1 1.8 11/14/2005 06:00:00 9.3 1 11.5 6.1 9.4 1 11.5 6.1 8.7 0.9 11.5 6.5 45 6 51 165 2 0 2.1 1.8 11/14/2005 06:10:00 8.7 1.1 11.1 5.7 8.8 1.1 11.1 5.3 8.2 1.1 11.1 5.7 47 8 52 165 2.1 0 2.3 1.8 11/14/2005 06:20:00 8.8 1.3 11.5 5.3 9 1.4 11.8 5.3 8.4 1.4 11.5 4.9 55 8 51 165 2.3 0 2.3 1.8 11/14/2005 06:30:00 9.2 1.4 13.3 5.7 9.3 1.5 13.3 5.7 8.7 1.3 11.8 5.3 58 8 54 165 2.4 0 2.6 2.1 11/14/2005 06:40:00 8.8 1.2 11.8 5.7 8.9 1.3 12.2 5.7 8.3 1.2 11.5 5.3 62 8 61 165 2.4 0 2.6 2.3 11/14/2005 06:50:00 10.4 1.3 13.7 6.8 10.6 1.4 14.1 6.8 10 1.2 13 6.1 64 8 54 165 2.7 0 2.8 2.6 11/14/2005 07:00:00 9.8 1.4 14.1 6.1 10 1.5 14.5 6.1 9.4 1.3 12.6 6.1 69 10 81 165 2.7 0 2.8 2.6 11/14/2005 07:10:00 10.9 1.4 14.9 7.2 11.2 1.5 15.3 7.2 10.5 1.3 14.1 7.2 70 8 70 165 3 0 3.3 2.8 11/14/2005 07:20:00 11.3 1.6 16.4 6.8 11.5 1.7 17.2 7.2 11 1.6 16.1 7.2 73 9 71 165 3.2 0 3.3 2.8 11/14/2005 07:30:00 10.6 1.5 14.5 6.5 10.9 1.6 14.5 6.1 10.4 1.5 15.3 6.5 73 9 84 165 3.3 0 3.5 2.8 11/14/2005 07:40:00 11.8 1.8 17.2 6.1 12 1.9 17.6 6.5 11.3 1.7 15.6 6.1 76 9 84 165 3.5 0 3.8 3 11/14/2005 07:50:00 12.6 1.5 16.1 8.8 12.8 1.6 16.8 8.8 12 1.4 15.3 7.2 80 8 68 165 3.6 0 3.8 3.5 11/14/2005 08:00:00 13.1 1.9 17.2 8.8 13.3 2 17.6 8.8 12.6 1.8 17.2 8.8 82 8 88 165 3.8 0 4 3.5 11/14/2005 08:10:00 13.9 1.8 18.7 8 14.3 1.9 19.1 8.4 13.5 1.8 18.7 9.1 83 7 88 165 3.9 0 4.3 3.5 11/14/2005 08:20:00 14.1 1.7 17.9 10.3 14.5 1.8 18.7 9.9 13.7 1.7 17.6 9.1 84 6 83 165 4 0 4.3 3.8 11/14/2005 08:30:00 13 1.6 16.8 9.1 13.3 1.6 16.8 9.1 12.5 1.5 16.4 8.8 83 7 77 165 4 0 4.3 3.8 11/14/2005 08:40:00 13.8 1.6 17.2 9.9 14.1 1.6 17.9 9.9 13.4 1.5 16.8 9.5 84 7 93 165 4.1 0 4.3 3.8 11/14/2005 08:50:00 15.5 2.4 21 9.5 15.7 2.4 21.4 9.9 14.5 2.4 21 9.1 106 12 112 165 3.5 0.5 4.3 2.6 11/14/2005 09:00:00 14.9 2 21 8.4 15.1 2 21 8.8 14.3 2.1 19.9 8 114 6 119 165 2.5 0.1 2.8 2.3 11/14/2005 09:10:00 13.5 1.5 18.3 10.3 13.6 1.5 17.9 10.3 12.6 1.7 16.4 8.4 115 7 107 165 2.3 0 2.6 2.1 11/14/2005 09:20:00 14.1 1.3 16.4 10.3 14.3 1.3 16.8 9.9 13.5 1.5 17.2 9.1 112 5 111 165 2.7 0.1 2.8 2.1 11/14/2005 09:30:00 14.6 1.8 19.9 9.1 14.8 1.9 20.2 8.4 13.8 2 19.5 8 105 8 109 165 2.7 0 2.8 2.6 11/14/2005 09:40:00 15.3 1.4 17.9 9.5 15.5 1.4 18.7 10.3 14.3 1.5 17.6 9.5 106 5 107 165 2.9 0.1 3.3 2.6 11/14/2005 09:50:00 14.2 1.3 16.8 9.1 14.4 1.2 16.8 9.5 13.6 1.5 16.8 9.9 114 7 111 165 3 0 3.3 2.8 11/14/2005 10:00:00 12.7 1.5 16.4 8.4 12.9 1.5 16.8 9.5 12 1.7 16.1 8 112 8 124 165 3.2 0 3.5 2.8 11/14/2005 10:10:00 12.2 1.5 15.6 8 12.4 1.5 15.6 8.4 11.3 1.6 15.3 6.8 101 7 99 165 3.4 0 3.5 3.3 11/14/2005 10:20:00 14.1 1.8 18.3 8.8 14.3 1.8 18.7 8.8 13 2 18.3 8.4 99 6 96 165 3.3 0 3.5 3.3 11/14/2005 10:30:00 13.7 1.4 17.2 8.4 14 1.4 17.6 9.1 12.8 1.5 16.8 8 98 6 96 165 3.2 0 3.3 3 11/14/2005 10:40:00 14.8 1.8 19.1 9.9 15.1 1.8 19.9 10.3 14.1 1.8 17.9 9.1 104 7 98 165 3 0 3.3 2.8 11/14/2005 10:50:00 13.5 1.7 17.6 9.5 13.7 1.8 17.6 9.1 12.6 1.9 16.8 8.4 100 8 94 165 2.8 0 3 2.6 11/14/2005 11:00:00 13.5 1.5 17.6 9.9 13.8 1.6 17.9 10.3 12.5 1.7 16.4 8.8 96 8 99 165 3 0 3.3 2.8 11/14/2005 11:10:00 14.2 1.5 17.9 9.5 14.5 1.5 17.9 9.5 13.4 1.5 17.2 9.9 94 7 98 165 3 0 3.3 2.8 11/14/2005 11:20:00 13.8 1.9 18.3 8.4 14 2 18.7 8.8 12.9 1.9 17.6 8.4 94 8 102 165 3.2 0 3.3 3 11/14/2005 11:30:00 13.8 1.5 16.8 9.1 14.1 1.6 17.6 8.4 13.1 1.6 16.4 7.6 89 8 95 165 3.2 0 3.3 3 11/14/2005 11:40:00 14.8 1.5 18.7 10.3 15.1 1.5 18.7 10.3 14 1.5 18.3 9.9 91 8 89 165 3.2 0 3.3 3 11/14/2005 11:50:00 15.1 1.8 18.7 10.3 15.4 1.9 19.5 9.9 14.3 2.1 19.1 8.4 98 7 97 165 3.3 0 3.5 3 11/14/2005 12:00:00 14.7 1.7 18.3 11.1 15 1.7 19.1 11.1 13.7 1.8 18.3 9.5 96 6 95 165 3.2 0 3.5 3 11/14/2005 12:10:00 13.2 1.6 17.2 8.4 13.5 1.7 17.6 8.4 12.6 1.6 16.4 8 86 9 87 165 3.3 0 3.5 3 11/14/2005 12:20:00 12.8 1.3 15.6 9.1 13.1 1.4 16.4 9.5 12.2 1.5 15.6 8.4 82 7 77 165 3.2 0 3.3 2.8 11/14/2005 12:30:00 11.4 1.5 14.5 7.2 11.7 1.6 14.9 7.6 11.1 1.4 14.5 6.8 77 8 73 165 3.2 0 3.3 3 11/14/2005 12:40:00 12.4 2.8 18.3 6.8 12.7 2.8 18.7 6.8 12 2.7 18.7 6.8 78 10 84 165 3.2 0 3.3 3 11/14/2005 12:50:00 14.1 2.7 20.2 8.8 14.4 2.8 20.6 9.1 13.4 2.6 19.5 8.4 80 7 85 165 3.2 0 3.3 3 11/14/2005 13:00:00 15.5 2 21.4 10.7 15.9 2.1 22.6 10.3 14.9 2.1 20.6 10.3 86 7 87 165 3.2 0 3.3 2.8 11/14/2005 13:10:00 15.7 2.1 20.6 10.7 16 2.1 21 10.7 14.8 2.1 19.9 9.1 93 9 95 165 3 0 3.3 2.8 11/14/2005 13:20:00 12.6 1.6 17.2 8.8 12.8 1.7 17.6 8.8 11.9 1.6 16.1 8.8 90 8 76 165 3 0 3.3 2.8 11/14/2005 13:30:00 14.8 2.1 19.9 9.9 15.1 2.2 20.6 9.5 14.3 2.2 20.2 8.8 85 8 84 165 3.3 0 3.5 3 11/14/2005 13:40:00 14.9 2.3 22.1 9.5 15.2 2.5 22.6 9.5 14.4 2.3 20.6 9.1 85 8 90 165 3.3 0 3.5 3.3 11/14/2005 13:50:00 15 2 20.2 10.7 15.3 2.2 20.6 10.3 14.2 2 20.2 9.9 83 9 80 165 3.3 0 3.5 3 11/14/2005 14:00:00 13.9 2.3 19.9 9.1 14.2 2.3 19.9 9.5 13.5 2.1 18.3 9.1 80 10 84 165 3.2 0 3.3 3 11/14/2005 14:10:00 13 1.9 17.6 7.2 13.3 2 17.9 7.2 12.6 1.7 17.6 9.1 77 10 89 165 3.2 0 3.3 2.8 11/14/2005 14:20:00 13.8 2.5 20.2 9.1 14.1 2.6 21 9.1 13.4 2.6 19.9 8.4 77 9 71 165 3.3 0 3.5 3 11/14/2005 14:30:00 15.2 2.8 22.1 7.2 15.6 2.9 22.1 8 14.7 2.6 21.8 8 81 10 85 165 3.3 0 3.5 3 11/14/2005 14:40:00 15.3 2.7 22.6 9.9 15.6 2.8 22.9 9.5 14.7 2.7 21.4 9.9 85 9 98 165 3.2 0 3.3 3 11/14/2005 14:50:00 13.8 2.2 19.1 9.1 14.1 2.2 19.9 9.5 13.3 2.1 17.9 8.8 78 9 82 165 3.3 0 3.5 3 11/14/2005 15:00:00 14.3 1.8 18.7 10.3 14.6 1.9 19.1 10.7 13.8 1.7 18.7 9.9 80 9 70 165 3.3 0 3.5 3.3 11/14/2005 15:10:00 14.2 1.7 18.3 9.1 14.5 1.9 19.5 9.5 13.6 1.8 18.7 8.8 77 9 84 165 3.3 0 3.5 3 11/14/2005 15:20:00 15.6 2.2 21.8 11.5 15.9 2.2 22.9 11.8 15 2.1 20.6 10.7 79 9 82 165 3.3 0 3.5 3 11/14/2005 15:30:00 13.6 2 19.1 8.4 13.8 2.1 19.5 8.8 13.1 1.9 18.3 8.8 79 9 84 165 3.2 0 3.3 3 11/14/2005 15:40:00 14.4 2.9 22.9 7.6 14.7 3.1 23.3 7.6 13.8 2.7 21.8 7.6 80 9 82 165 3.2 0 3.3 2.8 11/14/2005 15:50:00 14.4 2.8 23.7 8.8 14.7 2.9 23.7 9.1 13.8 2.8 23.3 8.4 78 9 81 165 3.4 0 3.5 3 11/14/2005 16:00:00 14.1 1.9 19.9 8.4 14.4 2 20.2 8 13.7 1.7 20.6 8.4 73 9 57 165 3.3 0 3.5 3 11/14/2005 16:10:00 14.7 2.4 21.8 8.4 15 2.5 22.9 8.8 14.3 2.4 21.8 9.5 74 9 65 165 3.3 0 3.5 3 11/14/2005 16:20:00 15.7 2.6 21.4 10.7 16.1 2.7 21.8 10.7 15.1 2.6 21.4 9.9 84 8 88 165 3.3 0 3.5 3 11/14/2005 16:30:00 15.4 1.9 20.2 10.7 15.7 2 20.6 11.1 14.5 1.8 18.7 9.9 88 8 85 165 3.3 0 3.5 3.3 11/14/2005 16:40:00 16.2 2.7 24 10.3 16.6 2.7 24.8 9.5 15.8 2.6 24 9.9 84 9 80 165 3.2 0 3.3 3 11/14/2005 16:50:00 14.3 2.1 19.5 9.1 14.6 2.2 19.9 9.9 13.9 2.1 19.1 8.4 76 10 87 165 3.1 0.1 3.3 3 11/14/2005 17:00:00 13.8 2.5 19.9 8 14.1 2.6 20.2 8 13.4 2.3 18.7 8 75 9 79 165 3 0 3.3 2.8 11/14/2005 17:10:00 14.4 2.5 20.6 8.4 14.7 2.6 21 8.4 14 2.3 20.2 8 68 10 77 165 3 0 3.3 2.8 11/14/2005 17:20:00 14.5 1.9 20.6 9.9 14.7 2 21 9.5 13.9 1.8 19.1 8.8 72 9 80 165 3 0 3.3 2.8 11/14/2005 17:30:00 13.2 1.9 19.9 7.2 13.4 2 20.2 7.6 12.6 1.8 17.6 7.6 71 9 81 165 3.1 0 3.3 3 11/14/2005 17:40:00 13.9 2.6 21 8 14.2 2.7 21 7.6 13.2 2.4 20.6 8.8 67 11 54 165 3 0 3.3 2.8 11/14/2005 17:50:00 14.3 2.3 19.9 9.1 14.5 2.4 20.2 8.8 13.8 2 19.9 8.4 68 9 66 165 3 0 3.3 2.8 11/14/2005 18:00:00 13.3 2.3 17.9 6.8 13.5 2.4 18.3 6.8 13 2.4 18.3 6.8 67 9 56 165 3 0 3.3 3 11/14/2005 18:10:00 14.1 1.9 18.7 8.4 14.3 2.1 19.5 8 13.5 2 19.1 8.4 67 8 83 165 3 0 3.3 3 11/14/2005 18:20:00 13.7 2.1 19.1 7.6 13.8 2.2 20.2 8.4 13.1 2 17.9 8 62 9 68 165 3 0 3.3 2.8 11/14/2005 18:30:00 12.4 2.2 17.6 7.2 12.5 2.3 17.9 7.6 12 2.1 17.2 6.8 61 9 63 165 3.2 0 3.3 2.8 11/14/2005 18:40:00 13.6 2.7 20.2 7.6 13.8 2.9 20.6 7.6 12.9 2.8 19.5 8 63 11 67 165 3.3 0 3.5 3 11/14/2005 18:50:00 11.7 2.3 18.3 6.5 11.8 2.4 18.3 6.5 11.3 2.2 17.2 6.8 58 10 69 165 3.3 0 3.5 2.8 11/14/2005 19:00:00 12.2 2.5 17.2 6.1 12.3 2.6 17.6 6.8 11.6 2.4 17.9 6.1 57 11 46 165 3.3 0 3.5 3 11/14/2005 19:10:00 12.1 2.2 17.9 7.6 12.2 2.3 18.3 7.2 11.7 2 17.2 6.5 56 11 53 165 3.4 0 3.5 3 11/14/2005 19:20:00 13.2 2.4 18.7 8 13.3 2.5 18.7 8.4 12.6 2.4 18.7 8 53 11 46 165 3.5 0 3.5 3.3 11/14/2005 19:30:00 12.3 1.9 18.3 7.6 12.4 2 18.7 7.2 11.7 1.9 17.9 7.2 50 10 53 165 3.5 0 3.5 3.3 11/14/2005 19:40:00 12.9 2.3 19.1 6.8 12.9 2.5 19.1 7.6 12.1 2.3 18.7 7.2 48 11 58 165 3.5 0 3.5 3.3 11/14/2005 19:50:00 12 2.4 18.7 6.5 12 2.4 18.7 6.8 11.3 2.4 19.5 6.1 46 12 34 165 3.5 0 3.5 3.3 11/14/2005 20:00:00 12.5 2.1 17.9 8 12.5 2.2 18.3 7.6 11.9 2.1 17.2 7.2 44 10 57 165 3.6 0 3.8 3.3 11/14/2005 20:10:00 12.7 2.6 19.1 6.8 12.6 2.7 19.5 6.1 12.1 2.6 19.1 5.7 42 11 39 165 3.6 0 3.8 3.3 11/14/2005 20:20:00 12.4 2.6 18.3 4.9 12.4 2.7 19.1 4.6 11.8 2.6 18.3 4.9 44 11 48 165 3.8 0 3.8 3.5 11/14/2005 20:30:00 13.6 2.1 19.1 8.8 13.5 2.1 19.1 8.4 13.1 2.1 19.1 8 42 10 45 165 3.8 0 3.8 3.5 11/14/2005 20:40:00 14 3.2 22.1 7.2 14.1 3.2 22.9 6.8 13.3 3.1 21.4 6.5 47 11 48 165 3.8 0 4 3.8 11/14/2005 20:50:00 14 2.5 19.5 8 13.9 2.5 20.2 8 13.3 2.5 19.9 8.4 40 10 54 165 3.8 0 4 3.5 11/14/2005 21:00:00 13.9 2.3 21 8.8 13.8 2.3 20.6 8.4 13.2 2.3 19.1 7.6 37 9 42 165 4 0 4.3 3.5 11/14/2005 21:10:00 13.8 2.3 20.6 7.2 13.7 2.4 19.9 7.2 13.2 2.5 19.1 7.6 37 8 36 165 4 0 4.3 3.8 11/14/2005 21:20:00 11.7 2.1 17.9 6.5 11.6 2.1 17.9 6.1 11.2 2 18.7 6.1 40 10 39 165 4.1 0 4.3 3.8 11/14/2005 21:30:00 11.8 1.9 17.6 7.2 11.7 2 17.9 6.8 11.2 1.9 16.4 6.1 39 12 34 165 4.2 0 4.5 3.8 11/14/2005 21:40:00 12.8 2.1 18.3 8 12.7 2.2 18.7 7.6 12.2 2.1 18.3 7.2 36 10 29 165 4.3 0 4.5 4 11/14/2005 21:50:00 12.5 2 18.3 8.4 12.4 2 18.3 8.4 12.1 1.9 17.6 7.2 38 9 34 165 4.3 0 4.5 4 11/14/2005 22:00:00 12.6 1.7 17.6 8.8 12.5 1.8 17.6 8.4 12.1 1.7 16.4 7.2 39 11 54 165 4.3 0 4.5 4.3 11/14/2005 22:10:00 12.6 2.3 18.3 7.2 12.5 2.4 18.3 7.2 12 2.3 17.9 6.8 36 12 29 165 4.3 0 4.5 4.3 11/14/2005 22:20:00 14.5 2.8 22.6 8.4 14.5 2.9 22.9 8.8 14 2.8 22.1 8 36 9 37 165 4.3 0 4.5 4.3 11/14/2005 22:30:00 13.1 2.4 20.2 7.6 13.1 2.4 19.9 6.8 12.5 2.2 17.6 7.2 39 9 19 165 4.3 0 4.5 4.3 11/14/2005 22:40:00 13.7 2 17.9 8 13.6 2.2 17.9 7.2 13.2 2 17.6 8 34 9 40 165 4.3 0 4.5 4.3 11/14/2005 22:50:00 13.9 2.2 19.9 7.2 13.7 2.3 19.9 6.8 13.1 2.4 19.9 7.2 34 10 37 165 4.3 0 4.5 4.3 11/14/2005 23:00:00 13.4 2.3 19.1 8 13.2 2.3 19.1 7.6 12.8 2.1 18.3 8 34 9 43 165 4.2 0 4.5 4.3 11/14/2005 23:10:00 14.7 2.1 19.9 9.9 14.4 2.3 19.9 9.5 13.9 2.1 19.1 8.8 32 9 23 165 4.3 0 4.5 4.3 11/14/2005 23:20:00 14.6 2.6 21.4 8.8 14.4 2.8 21.8 8 14 2.5 20.6 7.2 33 11 22 165 4.3 0 4.5 4.3 11/14/2005 23:30:00 13.6 2 18.7 8.4 13.2 2.1 18.7 8 13 2 18.3 8 25 10 25 165 4.4 0 4.5 4.3 11/14/2005 23:40:00 14.5 2.3 20.2 8.8 14.1 2.4 19.5 9.1 13.9 2.3 19.1 8.8 27 9 37 165 4.4 0 4.5 4.3 11/14/2005 23:50:00 15.3 2.6 21.4 9.5 14.9 2.8 21.4 9.1 14.5 2.6 21.4 9.1 27 10 23 165 4.4 0 4.5 4.5 11/15/2005 00:00:00 15.6 2.4 22.6 9.5 15 2.6 22.1 7.2 14.8 2.4 21.4 9.5 23 9 26 165 4.4 0 4.5 4.3 11/15/2005 00:10:00 15.3 2.3 21 10.3 14.5 2.4 20.2 9.5 14.5 2.1 20.6 9.9 19 8 17 165 4.4 0 4.5 4.3 11/15/2005 00:20:00 16.5 2.1 22.1 11.5 15.7 2.3 21.8 10.3 15.7 2.1 21 10.7 19 8 19 165 4.4 0 4.5 4.3 11/15/2005 00:30:00 15.4 2.2 21 10.7 14.5 2.4 21.4 9.1 14.8 2.3 21.4 10.3 19 9 28 165 4.4 0 4.5 4.3 11/15/2005 00:40:00 15.5 2.4 21.4 9.1 13.8 2.7 21 7.6 14.8 2.4 21 9.9 14 8 11 165 4.4 0 4.5 4.3 11/15/2005 00:50:00 15.8 2.6 22.1 9.9 14.6 2.7 21.4 8.8 15.1 2.5 22.9 8 18 9 13 165 4.4 0 4.5 4.3 11/15/2005 01:00:00 15.9 2.2 20.6 10.7 14.3 2.7 20.2 7.6 15.2 2.3 19.9 10.7 15 8 14 165 4.3 0 4.5 4.3 11/15/2005 01:10:00 15.4 1.8 20.6 10.3 13.5 2.4 19.9 6.8 14.7 1.7 21.4 9.9 12 9 11 165 4.3 0 4.5 4.3 11/15/2005 01:20:00 16 2.4 22.6 10.7 12.9 2.4 20.2 6.8 15.5 2.4 21.8 9.9 9 8 14 165 4.1 0 4.3 4 11/15/2005 01:30:00 15.5 1.7 19.9 11.1 12.8 2.2 17.9 7.2 14.9 1.9 19.9 9.1 10 7 8 165 4.1 0 4.3 4.3 11/15/2005 01:40:00 16 1.8 21.8 11.1 12.4 1.9 17.2 7.2 15.6 1.9 21.4 11.5 7 8 7 165 4.1 0 4.3 4 11/15/2005 01:50:00 16.5 2.1 22.1 10.7 13.6 2.8 20.6 7.6 15.9 2.3 23.3 10.3 9 9 2 165 4.1 0 4.3 4 11/15/2005 02:00:00 16.7 1.8 21 11.8 12.6 2.4 19.5 8.4 16.2 1.7 20.2 11.5 2 8 7 165 4 0 4.3 4 11/15/2005 02:10:00 16.6 2 22.1 12.2 12.8 2.4 18.3 8.4 16.1 1.8 20.6 11.1 5 7 3 165 4 0 4.3 4 11/15/2005 02:20:00 16.1 2.3 22.6 10.3 12.5 2.6 20.2 7.2 15.3 2.4 21.8 10.3 7 8 1 165 4 0 4.3 3.8 11/15/2005 02:30:00 15 1.7 19.9 10.7 11.9 2.5 18.7 8 14.4 1.9 19.5 8.8 6 11 11 165 3.9 0 4 3.8 11/15/2005 02:40:00 15.9 2 21 10.7 12 2.8 20.2 6.8 15.3 2 21 11.1 5 8 12 165 4 0 4.3 3.8 11/15/2005 02:50:00 15.7 1.7 20.2 11.5 11.6 2.1 17.6 8 15.5 1.8 19.9 11.1 6 6 1 165 3.9 0 4 3.8 11/15/2005 03:00:00 14.8 1.6 18.3 11.1 11.6 2.3 18.3 7.2 14.4 1.7 18.7 9.9 3 9 19 165 3.8 0 4 3.8 11/15/2005 03:10:00 13 1.7 18.3 9.1 10 2.1 16.4 6.5 12.7 1.8 18.3 8.8 2 9 358 165 3.8 0 3.8 3.8 11/15/2005 03:20:00 12.4 1.7 16.8 8 9.4 2.1 16.4 5.3 11.9 1.7 17.2 7.6 358 9 10 165 3.8 0 4 3.8 11/15/2005 03:30:00 12.5 1 15.3 9.9 10.4 1.8 14.1 6.5 12.2 1.2 15.3 8.8 358 12 350 165 3.7 0.1 4 3.5 11/15/2005 03:40:00 10.7 1.2 14.1 7.6 8.7 1.8 14.1 5.3 10.3 1.3 13.7 6.5 355 8 7 165 3.5 0 3.5 3.3 11/15/2005 03:50:00 12.4 1.5 17.6 8.8 9.5 1.7 15.6 5.7 12 1.7 16.4 7.2 358 7 359 165 3.4 0 3.5 3.3 11/15/2005 04:00:00 10.9 1.3 13.7 8 9.2 1.8 14.1 4.9 10.5 1.3 14.1 7.6 352 9 5 165 3.2 0 3.5 3.3 11/15/2005 04:10:00 11.7 1.6 15.6 7.6 10.2 2.1 14.9 5.7 11.3 1.5 14.5 7.6 351 7 352 165 3.2 0 3.3 3 11/15/2005 04:20:00 13 1.9 17.9 8.4 10.1 2.5 17.6 6.1 12.4 2.1 18.7 7.6 356 8 6 165 3 0 3.3 2.8 11/15/2005 04:30:00 11 1.1 14.1 8.8 9.6 1.5 13.7 5.7 10.6 1.1 14.1 7.2 349 12 358 165 2.6 0.2 3 2.3 11/15/2005 04:40:00 9.5 1.5 13 6.1 9.2 1.7 13.3 4.6 8.6 1.3 13.3 5.7 337 13 321 165 2.2 0 2.3 2.1 11/15/2005 04:50:00 12 1.7 17.2 7.2 10.2 2.2 16.4 5.3 11.7 1.9 16.4 7.2 352 10 4 165 2 0 2.3 1.8 11/15/2005 05:00:00 10.6 1.3 15.6 8 9.9 1.7 15.6 5.7 10.4 1.2 14.5 8 343 10 345 165 2 0 2.3 1.8 11/15/2005 05:10:00 14.1 2.8 21 7.2 12.8 2.9 21.4 6.5 13.9 2.7 19.5 8.4 347 10 341 165 2.1 0 2.3 1.8 11/15/2005 05:20:00 15.8 2 22.9 11.1 13.9 2.3 19.1 8.8 15.5 2.1 21.8 10.3 349 11 0 165 2.3 0 2.6 2.1 11/15/2005 05:30:00 15.4 2.4 22.9 9.9 13.5 2.5 21.4 8 14.6 2.6 24.8 8.4 350 11 7 165 2.4 0 2.6 2.3 11/15/2005 05:40:00 13.7 2.5 21.4 8 12.9 2.4 20.2 8.4 13.1 2.6 22.1 7.6 341 12 347 165 2.4 0 2.6 2.3 11/15/2005 05:50:00 13.1 2.4 18.7 6.8 13 2.4 19.1 6.1 12.6 2.6 19.9 6.1 331 11 338 165 2.5 0 2.8 2.3 11/15/2005 06:00:00 13.6 1.9 18.3 8 13.5 1.9 17.9 8.4 13.1 2.1 18.3 7.6 328 13 325 165 2.4 0 2.6 2.3 11/15/2005 06:10:00 13.5 1.4 17.2 9.5 13.4 1.5 17.6 8.8 13.1 1.4 16.4 8 324 9 324 165 2.3 0 2.6 2.1 11/15/2005 06:20:00 12.9 1.2 15.6 8.8 12.8 1.1 15.6 8.8 12.7 1.1 15.6 10.3 326 9 332 165 2.1 0 2.3 1.8 11/15/2005 06:30:00 13.4 2.4 21 6.8 13.1 2.3 19.1 6.8 13.1 2.4 19.1 7.2 330 11 350 165 2.2 0 2.3 1.8 11/15/2005 06:40:00 12.9 1.5 17.2 9.5 12.6 1.5 16.8 9.1 12.2 1.5 16.4 8.8 326 12 343 165 2.1 0 2.3 2.1 11/15/2005 06:50:00 12.4 1.5 16.4 8.4 12.2 1.6 16.8 8.8 11.9 1.4 15.6 8.8 327 13 310 165 2.2 0 2.3 2.3 11/15/2005 07:00:00 13.2 1.7 17.9 8.8 13 1.8 17.9 7.6 12.5 1.8 17.6 7.6 324 16 345 165 2.3 0 2.6 2.3 11/15/2005 07:10:00 13.8 1.9 19.5 9.5 13.5 2 19.1 9.1 13.6 2 17.9 8.8 336 11 332 165 2.3 0 2.6 2.3 11/15/2005 07:20:00 15.9 1.5 19.9 11.8 15.6 1.7 20.6 9.9 15.5 1.7 19.9 9.9 335 9 334 165 2.4 0 2.6 2.3 11/15/2005 07:30:00 14.3 2.2 19.1 8.8 14.1 2.3 20.2 8.4 13.8 2.2 18.7 9.1 334 9 338 165 2.4 0 2.6 2.3 11/15/2005 07:40:00 14.7 1.9 19.1 9.1 14.6 2 19.1 9.5 14.6 1.9 19.5 9.5 337 10 332 165 2.5 0 2.8 2.3 11/15/2005 07:50:00 14.2 1.8 19.1 8.4 14 1.8 19.9 9.1 13.6 1.8 18.7 8.8 334 9 349 165 2.4 0 2.6 2.3 11/15/2005 08:00:00 13.7 1.9 17.9 9.1 13.2 2.1 17.9 8 13.4 1.9 17.9 8 338 12 355 165 2.5 0 2.6 2.3 11/15/2005 08:10:00 14.8 1.4 17.9 10.3 14.8 1.5 18.7 10.3 14.4 1.6 19.1 9.9 335 9 341 165 2.5 0 2.6 2.6 11/15/2005 08:20:00 13.7 1.9 18.7 8.4 13.4 2.1 18.3 5.7 13 2.1 18.7 7.2 336 9 351 165 2.5 0 2.6 2.3 11/15/2005 08:30:00 11.8 1.9 17.6 8 11.7 1.9 17.6 7.6 11.3 2 17.9 6.8 336 8 337 165 2.6 0 2.8 2.3 11/15/2005 08:40:00 11.7 1.3 16.1 8.4 11.5 1.3 16.1 8.4 11.3 1.4 16.1 8 332 10 340 165 2.6 0.1 2.8 2.3 11/15/2005 08:50:00 12.4 1.6 16.1 7.6 12.1 1.7 15.6 8 12.1 1.5 15.3 8.4 334 10 333 165 2.6 0 2.8 2.6 11/15/2005 09:00:00 11.6 1.3 15.3 8 11.5 1.3 14.5 7.6 11 1.6 14.5 6.5 321 12 333 165 2.6 0.1 2.8 2.3 11/15/2005 09:10:00 12.9 1.5 16.4 8.4 12.8 1.4 15.6 8.4 10.9 1.6 14.5 6.1 305 7 311 165 2.2 0 2.3 2.1 11/15/2005 09:20:00 14.9 1.1 17.9 10.3 14.7 1.1 17.6 10.7 12.6 1.3 15.3 8.4 303 5 299 165 2.2 0 2.3 2.1 11/15/2005 09:30:00 15.2 1.1 17.2 10.7 15.1 1.1 16.8 10.7 12.9 1.3 16.4 9.9 304 4 302 165 2.2 0 2.3 2.1 11/15/2005 09:40:00 15.1 1 17.6 12.2 14.9 1 17.2 12.2 14 1.2 17.2 9.9 308 4 301 165 2.4 0.1 2.6 2.3 11/15/2005 09:50:00 15.1 1.1 17.2 12.2 14.9 1.1 17.2 11.8 13.8 1.2 16.4 9.5 310 4 306 165 2.5 0 2.8 2.3 11/15/2005 10:00:00 14.7 1.2 17.2 11.5 14.6 1.2 17.2 11.5 11.6 1.7 16.1 7.2 305 4 309 165 2.4 0 2.8 2.3 11/15/2005 10:10:00 12.4 1.3 16.4 9.1 12.2 1.3 16.1 9.1 9.7 1.4 13.7 6.8 306 5 302 165 2.7 0 2.8 2.6 11/15/2005 10:20:00 11 0.7 13 9.1 10.9 0.7 12.6 8.8 8.5 1.1 11.5 6.1 305 4 305 165 2.8 0 2.8 2.6 11/15/2005 10:30:00 10.6 0.9 13 8 10.5 0.9 12.6 8 8.2 1 11.1 5.7 306 5 307 165 2.9 0 3.3 2.8 11/15/2005 10:40:00 9.4 1 12.2 6.8 9.3 1 12.6 6.8 7.8 1 11.5 5.3 307 7 309 165 3.2 0 3.5 3 11/15/2005 10:50:00 8.5 1.1 11.5 5.7 8.4 1.1 11.5 5.3 7.1 1.1 9.5 4.2 308 7 290 165 3 0.1 3.5 2.8 11/15/2005 11:00:00 9.3 1.2 12.6 5.7 9.2 1.2 12.6 5.7 8 1.4 11.1 4.6 309 7 312 165 2.7 0 2.8 2.6 11/15/2005 11:10:00 9.3 1 11.5 6.5 9.1 1 11.5 5.7 8.6 1.1 11.5 6.1 319 9 335 165 2.7 0 2.8 2.6 11/15/2005 11:20:00 9.4 1.3 11.8 6.1 9.3 1.3 11.5 5.7 8.8 1.3 11.5 5.3 319 10 315 165 2.8 0 3 2.6 11/15/2005 11:30:00 7.7 1 10.3 4.9 7.6 1 10.3 4.9 7.3 1 9.9 4.9 321 10 313 165 3 0 3 2.8 11/15/2005 11:40:00 8.8 1 11.1 6.5 8.7 1 11.1 6.5 8.4 1 11.1 4.9 319 9 327 165 3 0 3.3 2.8 11/15/2005 11:50:00 9.5 1 12.2 7.2 9.4 0.9 12.2 7.6 8 0.9 9.9 5.7 308 6 300 165 2.8 0 3 2.8 11/15/2005 12:00:00 9.7 1 11.8 7.6 9.6 1 11.8 7.2 8.8 1 11.5 6.5 314 6 312 165 2.7 0 2.8 2.6 11/15/2005 12:10:00 9.3 1.1 12.6 6.5 9.2 1.1 12.6 6.1 8.7 1.2 12.2 5.7 316 8 320 165 2.6 0 2.8 2.6 11/15/2005 12:20:00 9.1 0.8 11.1 7.2 9 0.7 10.7 7.2 8.4 1 10.7 6.1 313 6 305 165 2.6 0 2.8 2.6 11/15/2005 12:30:00 9.7 0.7 11.8 7.6 9.6 0.7 11.8 7.2 9.1 0.9 11.1 6.5 313 5 308 165 2.5 0 2.6 2.6 11/15/2005 12:40:00 8.8 1 11.5 5.7 8.8 1 11.5 6.1 7.9 1.1 11.1 4.9 312 6 309 165 2.5 0 2.8 2.6 11/15/2005 12:50:00 7.6 0.7 9.5 5.7 7.5 0.7 9.5 5.3 5.8 0.8 8 4.2 298 7 303 165 2.8 0 2.8 2.6 11/15/2005 13:00:00 6.8 1 9.5 4.2 6.9 1 9.1 4.2 6.2 1.2 9.5 2.6 288 8 278 165 2.9 0 3.3 2.8 11/15/2005 13:10:00 8.5 0.6 10.3 6.8 8.5 0.6 9.9 6.8 7.6 0.9 9.1 4.9 289 5 295 165 3 0 3.3 2.8 11/15/2005 13:20:00 9 0.5 9.9 7.6 9 0.5 9.9 7.6 6.4 0.6 8.4 4.6 296 3 294 165 3 0 3.3 3 11/15/2005 13:30:00 7.4 2 9.9 3 7.4 2 10.3 3.4 6.3 1.8 9.1 2.3 310 6 302 165 3.2 0.2 3.8 2.8 11/15/2005 13:40:00 2 1.3 4.6 0.4 2.1 1.3 4.9 0.4 1.7 1 4.2 0.4 302 82 333 165 4.8 0.4 5.5 3.8 11/15/2005 13:50:00 1.8 0.8 4.6 0.4 1.9 0.7 4.6 0.7 1.5 0.8 3.8 0.4 290 15 306 165 5.2 0.3 5.7 4.8 11/15/2005 14:00:00 3.3 1 4.9 1.1 3.4 1 4.9 1.1 2.7 0.8 4.2 0.7 298 13 294 165 4.4 0.1 4.8 4.3 11/15/2005 14:10:00 3.9 0.7 5.3 2.6 3.8 0.7 5.3 2.3 3.9 0.8 5.7 2.6 331 11 336 165 4.8 0.1 5 4.3 11/15/2005 14:20:00 4.6 0.7 6.1 3 4.6 0.7 5.7 3 4.2 0.9 5.7 2.3 309 11 311 165 4.3 0 4.8 4.3 11/15/2005 14:30:00 2.5 0.4 3.4 1.5 2.6 0.4 3.4 1.5 2.3 0.5 3.8 0.7 305 12 282 165 4.8 0.4 5.5 4.3 11/15/2005 14:40:00 2.4 0.4 3.4 1.5 2.6 0.4 3.4 1.5 2.1 0.5 3.4 0.7 280 8 280 165 5.2 0 5.5 5 11/15/2005 14:50:00 1.8 0.6 3.4 0.4 2.2 0.7 3.4 0.4 2 0.7 3 0.4 259 13 276 165 5.2 0 5.5 4.8 11/15/2005 15:00:00 2 0.5 3 1.1 2.4 0.4 3.4 1.1 2.2 0.3 3 1.1 261 12 284 165 4.3 0.3 5 3.5 11/15/2005 15:10:00 3 0.2 3.4 2.3 3 0.3 3.4 2.3 2.2 0.3 3 1.5 302 5 306 165 3.8 0 4.3 3.5 11/15/2005 15:20:00 1.8 0.3 2.6 1.1 1.9 0.3 2.6 1.1 1.6 0.3 2.6 0.7 287 15 308 165 4.3 0 4.5 3.8 11/15/2005 15:30:00 1.5 0.5 2.6 0.4 1.6 0.5 2.6 0.7 1.6 0.5 2.6 0.7 232 11 247 165 4.8 0.1 5 4.3 11/15/2005 15:40:00 0.7 0.4 1.5 0.4 0.9 0.4 1.5 0.4 0.9 0.4 1.9 0.4 222 7 226 165 4.8 0.2 5 4.3 11/15/2005 15:50:00 1.5 0.4 1.9 0.4 1.5 0.3 2.3 0.7 1.4 0.4 1.9 0.4 210 0 211 165 4.4 0.2 4.8 4.3 11/15/2005 16:00:00 1.9 0.3 2.6 0.7 1.9 0.3 2.3 1.1 2 0.3 2.6 1.1 193 12 184 165 4.6 0.1 4.8 4.3 11/15/2005 16:10:00 1.9 0.2 2.3 1.5 1.9 0.2 2.3 1.5 1.7 0.3 2.6 1.1 197 2 203 165 3.9 0.1 4.3 3.5 11/15/2005 16:20:00 2.9 0.6 4.2 1.9 2.8 0.5 3.8 1.9 2.8 0.4 3.4 1.9 183 11 180 165 3.8 0 4 3.5 11/15/2005 16:30:00 2.8 0.3 3.4 2.3 2.7 0.2 3 2.3 2.6 0.3 3.4 1.9 186 6 174 165 3.3 0 3.5 3.3 11/15/2005 16:40:00 2.3 0.2 2.6 1.9 2.2 0.2 2.6 1.9 2.2 0.2 3 1.9 194 0 193 165 3.5 0 3.5 3 11/15/2005 16:50:00 2.6 0.2 3 2.3 2.6 0.2 3 2.3 2.8 0.2 3.4 2.3 190 9 195 165 3.6 0 3.8 3.3 11/15/2005 17:00:00 2.1 0.3 2.6 1.5 2.1 0.3 2.6 1.5 2.3 0.3 2.6 1.5 190 5 181 165 3.5 0 4 3.5 11/15/2005 17:10:00 1.2 0.6 1.9 0.4 1.3 0.6 2.3 0.4 1.4 0.6 2.3 0.4 194 0 193 165 3.3 0 3.5 3.3 11/15/2005 17:20:00 0.4 0 0.4 0.4 0.4 0.1 0.7 0.4 0.4 0 0.4 0.4 194 0 165 165 3.4 0 3.5 3.3 11/15/2005 17:30:00 1.3 0.6 2.3 0.4 1.4 0.5 1.9 0.4 1.5 0.5 2.3 0.4 178 15 164 165 3.5 0 3.5 3.3 11/15/2005 17:40:00 0.7 0.5 1.9 0.4 0.7 0.5 1.9 0.4 0.8 0.6 2.3 0.4 164 3 165 165 3.3 0 3.5 3.3 11/15/2005 17:50:00 0.7 0.4 1.9 0.4 0.8 0.4 1.9 0.4 0.9 0.5 1.9 0.4 210 30 180 165 3.4 0.1 3.5 3.3 11/15/2005 18:00:00 2 0.4 2.6 1.1 1.9 0.4 2.6 1.1 2 0.4 2.6 1.1 172 6 170 165 3.4 0 3.5 3.3 11/15/2005 18:10:00 2.7 0.4 3.4 1.9 2.6 0.4 3.4 1.9 2.8 0.4 3.4 1.9 164 8 163 165 3.2 0 3.3 3 11/15/2005 18:20:00 3 0.2 3.4 2.6 2.9 0.2 3.4 2.3 3 0.2 3.4 2.3 158 5 164 165 3 0 3.3 2.8 11/15/2005 18:30:00 3 0.3 3.8 2.3 3 0.3 3.8 2.3 3 0.2 3.4 2.3 159 3 161 165 3.3 0 3.5 3 11/15/2005 18:40:00 3 0.2 3.4 2.6 2.9 0.2 3.4 2.6 2.9 0.2 3.4 2.3 162 2 164 165 3.2 0 3.3 2.8 11/15/2005 18:50:00 2.9 0.2 3.8 2.3 2.9 0.2 3.4 2.3 2.9 0.2 3.4 2.6 163 6 164 165 3.2 0 3.3 2.8 11/15/2005 19:00:00 2.5 0.4 3.4 1.5 2.5 0.4 3.4 1.5 2.5 0.3 3 1.5 156 4 164 165 3.2 0 3.3 3 11/15/2005 19:10:00 1.9 0.8 3.4 0.4 1.9 0.7 3.4 0.4 1.8 0.7 3.4 0.7 146 5 149 165 3.2 0 3.3 2.8 11/15/2005 19:20:00 2 0.5 3.4 0.7 2.1 0.5 3.4 1.1 1.9 0.5 3.4 0.7 148 6 147 165 3.2 0 3.3 3 11/15/2005 19:30:00 3 0.5 4.2 1.9 3.1 0.5 4.2 1.9 2.9 0.5 3.8 1.9 149 6 149 165 3.2 0 3.3 3 11/15/2005 19:40:00 3.3 0.4 4.6 2.3 3.3 0.4 4.2 2.6 3.3 0.3 4.2 2.6 156 6 155 165 3.2 0 3.5 3 11/15/2005 19:50:00 3.3 0.4 4.2 2.3 3.3 0.4 4.2 2.3 3.3 0.4 4.2 2.6 145 5 147 165 3.3 0 3.5 2.8 11/15/2005 20:00:00 3.3 0.3 3.8 2.6 3.3 0.3 3.8 2.6 3.2 0.3 4.2 2.3 143 5 143 165 3.2 0 3.5 3 11/15/2005 20:10:00 3.2 0.7 4.6 1.9 3.2 0.6 4.6 1.9 3.2 0.6 4.6 1.9 148 7 147 165 3.3 0 3.5 3 11/15/2005 20:20:00 3 0.4 4.2 2.3 3.1 0.4 4.2 2.3 3 0.3 3.8 2.3 149 7 145 165 3.3 0 3.5 3.3 11/15/2005 20:30:00 2.2 0.6 3.4 0.7 2.3 0.6 3.4 0.7 2.2 0.5 3 1.1 135 9 136 165 3.3 0 3.5 3 11/15/2005 20:40:00 3.2 0.4 4.2 2.3 3.2 0.4 4.2 2.3 3.2 0.4 4.2 2.3 140 4 140 165 3.3 0 3.5 3 11/15/2005 20:50:00 3.2 0.4 4.2 2.6 3.3 0.4 4.2 2.6 3.2 0.3 4.2 2.3 145 5 136 165 3.3 0 3.5 3 11/15/2005 21:00:00 3.6 0.5 5.3 2.6 3.6 0.5 5.3 2.6 3.4 0.5 4.9 2.3 137 8 131 165 3.3 0 3.5 3.3 11/15/2005 21:10:00 3.8 0.5 4.9 2.6 3.8 0.5 4.9 2.6 3.7 0.5 4.9 2.6 136 9 125 165 3.5 0 3.8 3.3 11/15/2005 21:20:00 3.1 0.6 4.9 1.5 3.1 0.6 4.9 1.9 3.1 0.6 4.9 2.3 148 8 146 165 3.5 0 3.5 3.3 11/15/2005 21:30:00 3.3 0.6 4.6 1.9 3.2 0.6 4.6 1.9 3 0.5 4.2 1.9 147 6 151 165 3.6 0 3.8 3.3 11/15/2005 21:40:00 3.6 0.8 6.1 1.9 3.6 0.7 5.7 1.9 3.2 0.7 5.3 1.9 151 9 149 165 3.8 0 4 3.5 11/15/2005 21:50:00 4.5 0.6 5.7 3 4.4 0.6 5.7 2.3 4.3 0.6 5.7 2.6 151 11 154 165 3.9 0 4.3 3.5 11/15/2005 22:00:00 3.6 0.5 4.6 2.3 3.6 0.5 4.6 2.3 3.5 0.5 4.6 2.3 148 8 146 165 3.8 0 4 3.5 11/15/2005 22:10:00 4.2 0.7 5.3 2.6 4.2 0.7 5.3 2.6 4.1 0.7 5.3 2.6 151 5 153 165 3.8 0 4 3.5 11/15/2005 22:20:00 4.3 0.6 5.7 3 4.4 0.6 5.3 3 4.3 0.6 5.7 2.6 148 5 155 165 3.9 0 4 3.5 11/15/2005 22:30:00 4.8 0.6 6.8 3.4 4.9 0.6 6.8 3.4 4.8 0.6 6.5 3.8 142 5 143 165 3.9 0 4 3.5 11/15/2005 22:40:00 4.9 0.7 6.5 3 4.9 0.6 6.1 3.4 4.9 0.7 6.1 3 141 8 147 165 3.8 0 3.8 3.5 11/15/2005 22:50:00 5.5 0.6 6.8 3.8 5.5 0.6 6.8 3.8 5.5 0.6 6.8 3.8 145 6 150 165 3.6 0 3.8 3.5 11/15/2005 23:00:00 4.9 0.6 6.5 3 4.8 0.5 6.1 3 4.8 0.6 6.1 3 146 8 149 165 3.4 0 3.5 3.3 11/15/2005 23:10:00 5.6 0.8 7.2 4.2 5.5 0.7 7.2 4.2 5.6 0.7 7.2 3.8 148 8 154 165 3.4 0 3.5 3.3 11/15/2005 23:20:00 5.5 1 7.2 3.4 5.5 0.9 6.8 3.8 5.4 0.9 7.2 3 147 6 155 165 3.5 0.1 3.8 3 11/15/2005 23:30:00 5.8 0.9 8 3.8 5.7 0.9 7.6 3.4 5.7 1 8.4 3.4 147 9 148 165 3.6 0 3.8 3.3 11/15/2005 23:40:00 6.4 0.8 8.4 4.6 6.4 0.7 8 4.6 6.3 0.7 8.4 4.2 149 6 148 165 3.6 0 3.8 3.5 11/15/2005 23:50:00 6.6 0.8 8.8 4.6 6.5 0.8 8.8 4.6 6.5 0.8 8.8 4.2 152 9 151 165 3.7 0.1 3.8 3.5 11/16/2005 00:00:00 7.4 0.8 9.9 5.3 7.3 0.8 9.5 5.3 7.4 0.8 9.5 5.7 152 13 162 165 3.5 0 3.5 3.3 11/16/2005 00:10:00 7.8 0.7 9.1 5.7 7.7 0.7 9.1 5.7 8 0.8 9.5 6.1 157 5 164 165 3.1 0.1 3.3 2.8 11/16/2005 00:20:00 7.7 0.6 8.8 6.1 7.6 0.5 8.8 6.1 7.7 0.6 9.1 6.1 153 5 159 165 2.8 0 3 2.6 11/16/2005 00:30:00 7.4 0.7 9.1 5.7 7.3 0.7 8.8 5.7 7.3 0.8 9.5 5.3 154 6 160 165 2.6 0 2.8 2.3 11/16/2005 00:40:00 8.1 0.8 9.9 6.1 8 0.8 9.9 6.1 8.2 0.8 10.7 6.5 150 5 148 165 2.4 0 2.6 2.3 11/16/2005 00:50:00 7.9 0.6 9.5 6.1 7.7 0.6 9.1 6.5 7.8 0.6 9.5 6.1 157 7 155 165 2.4 0 2.6 2.3 11/16/2005 01:00:00 7.5 0.8 9.5 5.7 7.4 0.8 9.1 5.7 7.6 0.8 9.5 5.3 159 16 156 165 2.2 0 2.6 2.1 11/16/2005 01:10:00 6.7 0.6 8.4 4.9 6.8 0.6 8.4 5.3 6.7 0.8 8.4 4.6 142 7 141 165 2 0 2.3 1.8 11/16/2005 01:20:00 7.1 0.6 9.1 5.7 7.1 0.6 8.8 6.1 7.2 0.6 8.8 5.7 142 2 139 165 2 0 2.1 1.8 11/16/2005 01:30:00 7.6 0.5 9.5 6.1 7.5 0.5 9.5 5.7 7.5 0.7 9.1 5.3 145 4 144 165 1.9 0 2.1 1.8 11/16/2005 01:40:00 7.7 1 10.3 4.9 7.5 1 9.9 4.9 7.9 1.1 10.3 4.9 150 2 151 165 1.8 0 1.8 1.6 11/16/2005 01:50:00 8.4 0.5 9.9 7.2 8.2 0.5 9.9 6.8 8.7 0.5 9.9 7.2 149 2 146 165 1.8 0 1.8 1.6 11/16/2005 02:00:00 7.7 0.7 9.5 6.1 7.5 0.6 9.1 6.1 7.9 0.8 9.9 5.7 153 0 154 165 1.8 0 1.8 1.6 11/16/2005 02:10:00 6.4 0.7 8.8 4.6 6.3 0.7 8.8 4.6 6.4 0.7 8.4 4.2 153 0 154 165 1.7 0 1.8 1.6 11/16/2005 02:20:00 5.6 0.7 7.2 3.8 5.5 0.6 7.2 3.8 5.5 0.8 7.6 3.4 153 0 154 165 1.6 0 1.8 1.4 11/16/2005 02:30:00 5 1.1 8 2.3 5.1 1.1 8 2.6 4.8 1 8 3 153 1 151 165 1.7 0 1.8 1.6 11/16/2005 02:40:00 5.2 0.8 8 3.8 5.3 0.8 7.6 3.8 5.3 0.8 7.6 3 150 0 150 165 1.8 0 1.8 1.6 11/16/2005 02:50:00 5.7 0.7 8 4.2 5.7 0.7 8.4 3.8 5.7 0.7 7.6 3.4 147 2 142 165 2.1 0.1 2.6 1.6 11/16/2005 03:00:00 6.5 0.8 8.4 4.2 6.5 0.7 8.4 4.2 6.5 0.8 8.4 4.2 138 7 143 165 2.9 0.2 3.3 2.3 11/16/2005 03:10:00 9.8 1.7 13 5.7 9.8 1.7 13.3 5.7 9.7 1.5 13 5.7 128 5 125 165 3.5 0.2 3.8 2.8 11/16/2005 03:20:00 9.8 0.9 12.6 7.2 9.8 1 12.6 7.2 9.5 0.9 11.8 7.6 132 7 131 165 3.9 0 4.3 3.5 11/16/2005 03:30:00 9.4 0.9 11.8 7.2 9.5 0.9 11.8 7.2 9.4 1 12.2 6.8 128 7 127 165 4.1 0.1 4.3 3.8 11/16/2005 03:40:00 10.1 0.9 12.6 8 10.3 0.9 12.6 8.4 10 1 12.6 8 124 5 116 165 4.3 0 4.5 4.3 11/16/2005 03:50:00 10.4 0.8 12.6 8.4 10.5 0.8 13 8.4 10.3 0.9 13 7.6 124 5 126 165 4.4 0 4.5 4.3 11/16/2005 04:00:00 8.7 1.3 11.5 4.9 8.9 1.3 11.8 5.3 8.7 1.5 11.8 5.3 121 6 128 165 4.5 0 4.8 4.3 11/16/2005 04:10:00 7.9 0.8 9.5 5.7 8 0.8 9.9 6.1 7.5 0.9 9.5 4.6 116 5 104 165 4.6 0 4.8 4.5 11/16/2005 04:20:00 7 1 9.1 5.3 7.1 1 9.1 5.3 6.7 1.1 9.1 4.2 118 4 102 165 4.6 0 4.8 4.5 11/16/2005 04:30:00 4.3 0.9 6.5 2.3 4.4 1 6.8 2.6 4.2 0.9 6.5 2.3 115 5 114 165 4.7 0 4.8 4.5 11/16/2005 04:40:00 4.1 0.6 5.3 3 4.2 0.6 5.3 3 4 0.5 5.3 2.6 101 12 96 165 4.8 0 5 4.5 11/16/2005 04:50:00 5.1 0.7 6.5 3.8 5.3 0.7 6.8 4.2 4.9 0.7 6.5 3.4 111 7 99 165 5.2 0 5.2 4.8 11/16/2005 05:00:00 4 0.8 6.5 2.6 4.1 0.8 6.1 2.6 3.6 0.7 5.7 1.9 110 9 114 165 5.2 0 5.5 5 11/16/2005 05:10:00 3.8 0.7 5.3 1.9 3.8 0.7 5.7 1.9 3.8 0.7 5.7 1.9 128 7 123 165 5.4 0 5.5 5 11/16/2005 05:20:00 1.6 0.8 3 0.4 1.6 0.8 3 0.4 1.4 1 3.8 0.4 108 17 117 165 5.2 0 5.5 5 11/16/2005 05:30:00 0.7 0.5 2.3 0.4 0.6 0.5 2.3 0.4 0.5 0.3 1.9 0.4 139 17 123 165 5 0 5 4.8 11/16/2005 05:40:00 0.8 0.5 2.3 0.4 0.7 0.5 1.9 0.4 0.6 0.4 1.9 0.4 166 7 162 165 5.1 0 5.5 5 11/16/2005 05:50:00 1.9 0.4 2.6 1.1 1.8 0.3 2.6 1.1 1.9 0.3 2.6 1.1 159 7 164 165 5.4 0 5.5 5.2 11/16/2005 06:00:00 3.1 0.3 3.8 1.9 2.9 0.3 3.4 2.3 3 0.3 3.8 2.3 158 4 155 165 5.3 0.1 5.7 5 11/16/2005 06:10:00 2.5 0.4 3.4 1.5 2.3 0.4 3.4 1.5 2.4 0.3 3 1.5 165 8 158 165 5.1 0 5.2 4.8 11/16/2005 06:20:00 2.2 0.5 3.8 0.4 2 0.4 3.4 0.4 1.9 0.4 3 0.7 177 15 196 165 5.1 0 5.2 4.8 11/16/2005 06:30:00 3.6 0.7 5.3 1.1 3.5 0.7 5.3 1.5 3.5 0.5 4.9 2.3 153 11 148 165 4.9 0.1 5.2 4.5 11/16/2005 06:40:00 5.9 0.9 8 3.4 5.7 0.9 8.4 3.4 5.6 0.8 7.6 3 161 12 154 165 4.4 0.2 4.8 4 11/16/2005 06:50:00 5.9 0.5 7.6 4.2 5.7 0.5 7.2 3.8 5.7 0.6 6.8 3.8 157 6 177 165 4.1 0 4.3 4 11/16/2005 07:00:00 5 0.6 7.6 3.8 4.8 0.6 6.8 3.8 4.6 0.4 6.5 3.8 161 8 170 165 3.9 0 4.3 3.8 11/16/2005 07:10:00 5 0.5 6.8 3.4 4.7 0.5 6.5 3.4 5 0.4 6.5 3.8 161 9 164 165 3.9 0 4 3.8 11/16/2005 07:20:00 5.1 0.8 7.2 3 4.9 0.7 6.5 3 5 0.6 6.8 3.4 164 9 166 165 4.1 0 4.3 3.8 11/16/2005 07:30:00 5.5 0.6 7.2 4.2 5.2 0.5 6.5 4.2 5.2 0.6 6.8 3.8 167 10 160 165 4.1 0 4.5 3.8 11/16/2005 07:40:00 6.4 0.9 8.8 4.2 6.2 0.9 8.4 4.2 6.1 0.8 8 4.6 165 8 170 165 4.2 0.1 4.5 4 11/16/2005 07:50:00 7.3 0.7 8.8 5.3 7 0.7 8.4 5.3 6.9 0.7 8.8 5.3 170 12 164 165 4.6 0.1 4.8 4.3 11/16/2005 08:00:00 7.4 1 9.9 4.9 7.1 0.9 9.5 4.6 7 0.8 9.1 5.3 171 7 179 165 5 0.3 5.5 4.5 11/16/2005 08:10:00 6.7 0.7 8.8 4.9 6.5 0.7 8.4 4.6 6.4 0.7 8.4 4.6 177 6 190 165 5.2 0 5.5 5 11/16/2005 08:20:00 6.1 0.6 8 4.9 5.9 0.6 7.6 4.2 5.9 0.6 7.2 4.2 185 8 176 165 5.4 0 5.7 5 11/16/2005 08:30:00 5.5 0.5 6.5 4.2 5.5 0.5 6.8 4.2 5.2 0.5 6.1 4.2 192 4 201 165 5.4 0 5.7 5.2 11/16/2005 08:40:00 6.4 0.6 7.6 4.6 6.2 0.5 7.2 4.6 5.9 0.7 7.2 4.2 182 8 176 165 5.3 0 5.5 5 11/16/2005 08:50:00 7.2 0.3 7.6 6.1 6.8 0.3 7.2 5.7 6.3 0.5 7.6 5.3 172 4 174 165 5.2 0 5.5 5.2 11/16/2005 09:00:00 7.1 0.4 8.4 5.7 6.7 0.4 8 5.7 6.4 0.5 7.6 4.9 176 4 176 165 5.3 0.1 5.7 5 11/16/2005 09:10:00 6.7 0.4 7.6 4.9 6.4 0.4 7.6 4.9 6 0.5 7.2 4.6 181 4 182 165 5.7 0 6 5.5 11/16/2005 09:20:00 6.2 0.6 7.6 4.6 5.9 0.5 7.2 4.6 5.6 0.6 6.8 3.8 179 4 171 165 5.9 0 6 5.7 11/16/2005 09:30:00 5.5 0.8 7.2 3 5.3 0.7 6.8 3.4 4.8 0.7 6.5 2.6 183 7 191 165 6 0 6.2 5.7 11/16/2005 09:40:00 4.1 1.2 6.5 1.9 3.9 1.2 6.1 1.5 3.8 1 6.1 2.3 170 12 187 165 6 0.1 6.2 5.7 11/16/2005 09:50:00 3.5 0.6 4.9 1.1 3.4 0.6 4.9 1.5 3.4 0.5 4.6 2.3 146 14 140 165 5.7 0 6 5.5 11/16/2005 10:00:00 3.8 0.5 5.3 2.6 3.7 0.5 5.3 2.6 3.9 0.6 5.3 2.6 143 9 146 165 5.7 0 6 5.5 11/16/2005 10:10:00 4.3 0.5 5.3 3 4.2 0.5 4.9 2.6 4.2 0.6 5.3 2.6 147 7 143 165 5.7 0 6 5.5 11/16/2005 10:20:00 3.7 0.6 5.3 2.6 3.6 0.6 5.3 2.3 3.6 0.5 4.9 2.3 146 9 153 165 6.1 0 6.2 5.7 11/16/2005 10:30:00 4.2 0.6 5.3 3 4 0.5 5.3 2.6 4.1 0.4 5.3 3 164 12 150 165 6.1 0 6.2 5.7 11/16/2005 10:40:00 3.5 0.9 5.3 1.5 3.4 0.8 5.3 1.5 3.5 0.8 5.3 1.9 181 13 165 165 6.1 0 6.2 5.7 11/16/2005 10:50:00 3.2 0.8 5.3 1.5 3.1 0.7 4.9 1.5 3.2 0.8 5.3 1.5 181 12 177 165 6.2 0 6.2 6 11/16/2005 11:00:00 4.4 0.6 5.7 2.6 4.2 0.6 5.3 2.6 4.4 0.7 6.1 3 166 9 162 165 6.3 0 6.7 6.2 11/16/2005 11:10:00 3.8 0.6 5.3 1.9 3.7 0.5 4.9 2.3 3.8 0.6 5.3 2.3 165 10 178 165 6.3 0 6.5 6.2 11/16/2005 11:20:00 2.7 0.8 4.9 0.7 2.6 0.8 4.9 0.7 2.7 0.7 5.3 1.5 165 13 175 165 6.4 0 6.7 6.2 11/16/2005 11:30:00 2 1.2 4.9 0.4 1.9 1.2 4.9 0.4 1.9 1.2 4.9 0.4 179 27 164 165 6.6 0 6.7 6.5 11/16/2005 11:40:00 3.3 0.8 5.3 0.4 3.2 0.8 5.3 0.4 3.1 0.8 4.9 0.7 190 15 221 165 6.6 0 6.7 6.2 11/16/2005 11:50:00 3.4 0.5 4.6 1.9 3.3 0.5 4.6 1.9 3.3 0.4 4.2 2.3 169 9 175 165 6.5 0 6.7 6.2 11/16/2005 12:00:00 2.9 0.6 4.6 1.5 2.9 0.6 4.2 1.5 2.8 0.6 4.6 1.1 159 13 144 165 6.6 0 6.7 6.5 11/16/2005 12:10:00 2.9 0.6 4.6 1.9 2.9 0.6 4.6 1.9 3.1 0.5 4.6 1.9 155 11 165 165 6.6 0 6.7 6.5 11/16/2005 12:20:00 1.9 0.6 3.4 0.4 1.8 0.6 3 0.4 1.7 0.7 3 0.4 175 33 217 165 6.7 0 6.7 6.2 11/16/2005 12:30:00 2.5 0.8 4.2 0.7 2.4 0.7 3.8 0.7 2.4 0.6 4.2 1.1 198 12 181 165 6.7 0 7 6.5 11/16/2005 12:40:00 3.4 0.7 5.3 1.9 3.3 0.7 4.9 1.5 3.4 0.6 4.9 1.9 179 9 178 165 6.7 0 7 6.7 11/16/2005 12:50:00 3.7 0.6 5.3 1.9 3.6 0.6 4.9 2.3 3.7 0.5 5.3 2.3 161 13 160 165 6.6 0 6.7 6.5 11/16/2005 13:00:00 2.4 0.8 4.2 0.7 2.3 0.7 3.8 0.4 2.2 0.7 4.2 0.7 172 12 176 165 6.6 0 6.7 6.5 11/16/2005 13:10:00 1.7 0.5 3 0.4 1.6 0.5 3.4 0.4 1.4 0.5 2.6 0.4 168 11 174 165 6.6 0 6.7 6.2 11/16/2005 13:20:00 2.1 0.7 3.8 0.7 2 0.7 3.4 0.4 1.5 0.7 3.8 0.4 195 10 192 165 6.7 0 7 6.2 11/16/2005 13:30:00 2.9 0.6 4.2 1.1 2.8 0.6 4.2 1.1 3 0.6 4.2 1.5 154 15 133 165 6.7 0 7 6.5 11/16/2005 13:40:00 4.5 0.4 5.3 3.4 4.5 0.4 5.3 3.8 4.6 0.4 5.7 3.8 145 5 144 165 6.6 0 6.7 6.5 11/16/2005 13:50:00 3.9 0.3 4.6 3 3.8 0.3 4.6 3 4 0.3 4.9 3 158 5 148 165 6.4 0 6.7 6.2 11/16/2005 14:00:00 3.1 0.5 4.2 1.9 2.9 0.5 4.2 1.9 3.1 0.5 4.2 2.3 172 6 174 165 6.4 0 6.7 6.2 11/16/2005 14:10:00 2.1 0.4 3.4 1.1 1.9 0.4 3 1.1 2 0.4 3 1.1 169 5 166 165 6.5 0 6.7 6.2 11/16/2005 14:20:00 1.7 0.4 2.6 0.7 1.6 0.4 2.3 0.7 1.6 0.5 2.3 0.4 152 10 165 165 6.5 0 6.7 6.2 11/16/2005 14:30:00 2 0.4 3.4 0.7 1.9 0.4 3.4 0.7 1.8 0.4 2.6 0.7 153 11 139 165 6.6 0 6.7 6.5 11/16/2005 14:40:00 0.7 0.5 2.3 0.4 0.6 0.4 1.9 0.4 0.8 0.5 2.3 0.4 148 2 153 165 6.6 0 6.7 6.2 11/16/2005 14:50:00 1.4 0.8 3.4 0.4 1.2 0.7 3.4 0.4 1.1 0.6 2.6 0.4 174 15 196 165 6.6 0 6.7 6.5 11/16/2005 15:00:00 2.1 0.5 3 0.4 1.9 0.6 3 0.4 1.9 0.6 3 0.4 169 15 184 165 6.7 0 7 6.7 11/16/2005 15:10:00 3.8 0.6 4.9 2.6 3.8 0.6 5.3 2.6 3.9 0.6 5.3 2.3 141 4 144 165 6.6 0 6.7 6.5 11/16/2005 15:20:00 4.9 0.2 5.3 4.2 4.7 0.3 5.7 3.8 4.8 0.3 5.3 3.8 149 7 141 165 6.4 0 6.5 6.2 11/16/2005 15:30:00 3.9 0.5 5.3 3 3.6 0.5 4.9 2.6 3.9 0.5 4.9 2.6 162 3 164 165 6.4 0 6.7 6.2 11/16/2005 15:40:00 2.8 0.3 3.4 1.9 2.6 0.3 3.4 1.9 2.6 0.3 3.4 1.9 165 3 164 165 6.4 0 6.7 6.2 11/16/2005 15:50:00 2.4 0.3 3.4 1.5 2.2 0.3 3 1.5 2.2 0.4 3 1.5 171 5 166 165 6.4 0 6.5 6.2 11/16/2005 16:00:00 3.1 0.3 3.8 2.3 2.9 0.2 3.4 2.3 2.9 0.3 3.4 2.3 163 3 162 165 6.5 0 6.7 6.2 11/16/2005 16:10:00 1.8 0.4 2.6 0.7 1.6 0.4 2.6 0.7 1.7 0.5 3 0.7 168 2 164 165 6.5 0 6.7 6.2 11/16/2005 16:20:00 1.3 0.4 2.3 0.4 1.1 0.4 1.9 0.4 1.1 0.4 1.9 0.4 167 4 164 165 6.4 0 6.7 6.2 11/16/2005 16:30:00 1.2 0.5 2.3 0.4 1 0.5 2.3 0.4 1 0.5 1.9 0.4 152 9 161 165 6.4 0 6.5 6.2 11/16/2005 16:40:00 1.3 0.3 1.9 0.7 1.1 0.4 1.9 0.4 1 0.5 1.9 0.4 158 6 159 165 6.4 0 6.7 6.2 11/16/2005 16:50:00 2.1 0.2 2.6 1.5 2 0.2 2.3 1.1 2 0.3 2.6 1.5 160 3 162 165 6.4 0 6.7 6.2 11/16/2005 17:00:00 2.1 0.6 3.4 0.7 1.9 0.6 3.4 0.7 2 0.5 3.4 0.7 158 6 165 165 6.3 0 6.2 6 11/16/2005 17:10:00 3.2 0.5 4.2 1.5 2.9 0.5 3.8 1.1 3.1 0.5 4.2 1.5 165 9 167 165 6.3 0 6.5 6 11/16/2005 17:20:00 3.1 0.4 4.2 2.3 2.8 0.4 3.4 1.9 2.9 0.4 4.2 1.9 175 7 173 165 6.3 0 6.5 6.2 11/16/2005 17:30:00 2.8 0.4 3.4 1.9 2.6 0.3 3.4 1.5 2.6 0.4 3.4 1.9 171 7 178 165 6.3 0 6.2 6.2 11/16/2005 17:40:00 2.8 0.3 3.4 1.9 2.5 0.3 3 1.5 2.5 0.4 3.4 1.5 171 5 172 165 6.3 0 6.2 6.2 11/16/2005 17:50:00 2.6 0.3 3.4 2.3 2.4 0.2 3 1.9 2.4 0.3 3 1.5 176 2 174 165 6.3 0 6.2 6.2 11/16/2005 18:00:00 2.9 0.2 3.4 2.3 2.6 0.2 3 1.9 2.7 0.2 3 1.9 167 5 164 165 6.3 0 6.5 6.2 11/16/2005 18:10:00 3.5 0.3 4.2 3 3.2 0.3 3.8 2.6 3.3 0.2 3.8 2.6 164 3 159 165 6.2 0 6.2 6 11/16/2005 18:20:00 3.7 0.3 4.2 3 3.3 0.3 3.8 2.6 3.4 0.3 4.2 2.6 168 7 163 165 6.2 0 6.2 6 11/16/2005 18:30:00 4.1 0.2 4.6 3 3.8 0.2 4.2 3 3.9 0.4 4.6 2.6 178 2 177 165 6.2 0 6.2 5.7 11/16/2005 18:40:00 4.4 0.2 4.9 4.2 4.1 0.2 4.6 3.8 4.5 0.2 4.9 4.2 176 2 170 165 6.3 0 6.2 6 11/16/2005 18:50:00 4.5 0.2 4.9 4.2 4.2 0.2 4.6 3.8 4.5 0.2 4.9 3.8 175 3 176 165 6.3 0 6.5 6 11/16/2005 19:00:00 3.9 0.2 4.6 3.4 3.6 0.2 4.2 3 3.8 0.3 4.6 3.4 178 1 179 165 6.3 0 6.5 6.2 11/16/2005 19:10:00 3.9 0.2 4.2 3.4 3.5 0.2 4.2 3 3.6 0.2 4.2 3 170 10 178 165 6.3 0 6.5 6 11/16/2005 19:20:00 3.8 0.4 4.6 3 3.5 0.4 4.2 2.6 3.7 0.4 4.6 2.6 161 6 162 165 6.5 0 6.7 6.2 11/16/2005 19:30:00 2.9 0.4 3.4 1.5 2.6 0.4 3.4 1.5 2.7 0.4 3.4 1.9 170 6 165 165 6.4 0 6.7 6.2 11/16/2005 19:40:00 2.7 0.2 3.4 2.3 2.5 0.2 3 1.9 2.4 0.3 3 1.5 176 3 176 165 6.4 0 6.7 6.2 11/16/2005 19:50:00 3.4 0.2 3.8 3 3.1 0.2 3.4 2.6 3.3 0.2 3.8 3 168 5 168 165 6.5 0 6.7 6.2 11/16/2005 20:00:00 3 0.3 3.8 1.9 2.8 0.3 3.4 1.9 3 0.3 3.4 1.9 159 5 160 165 6.4 0 6.7 6.2 11/16/2005 20:10:00 3.7 0.3 4.6 3 3.5 0.3 4.2 2.6 3.6 0.3 4.2 2.6 158 4 159 165 6.4 0 6.5 6.2 11/16/2005 20:20:00 3.6 0.4 4.6 2.6 3.4 0.4 4.2 2.3 3.5 0.3 4.6 3 159 4 157 165 6.2 0 6.2 6 11/16/2005 20:30:00 3.9 0.5 5.3 3 3.6 0.5 4.9 2.6 3.8 0.5 4.9 2.6 167 6 174 165 6.2 0 6.2 6 11/16/2005 20:40:00 3.8 0.9 5.3 1.9 3.5 0.8 4.9 1.9 3.6 0.8 5.3 1.9 170 5 167 165 6.2 0 6.2 6 11/16/2005 20:50:00 3.5 0.4 4.2 2.6 3.2 0.4 4.2 2.3 3.5 0.4 4.6 2.6 175 4 173 165 6.2 0.1 6.5 6 11/16/2005 21:00:00 3.3 0.3 3.8 2.6 3 0.3 3.8 2.3 3.1 0.3 3.8 2.3 176 6 178 165 6.3 0 6.5 6.2 11/16/2005 21:10:00 3.8 0.2 4.2 3.4 3.4 0.2 4.2 3 3.5 0.3 4.2 2.6 178 1 178 165 6.2 0 6.2 6.2 11/16/2005 21:20:00 3.3 0.5 4.6 2.6 3.1 0.4 4.2 2.3 3.2 0.4 4.2 2.3 190 9 179 165 6.2 0 6.2 6.2 11/16/2005 21:30:00 2.9 0.2 3.4 2.3 2.8 0.3 3.4 2.3 2.7 0.3 3.4 1.9 207 4 205 165 6.4 0 6.5 6.2 11/16/2005 21:40:00 3 0.4 3.8 1.9 2.8 0.5 3.8 1.9 2.5 0.4 3.8 1.5 216 5 228 165 6.4 0 6.7 6.2 11/16/2005 21:50:00 3.5 0.3 4.2 2.6 3.4 0.3 4.2 2.6 3.2 0.3 3.8 2.3 227 6 231 165 6.6 0 6.7 6.5 11/16/2005 22:00:00 3.2 0.5 4.2 1.5 3 0.5 4.2 1.1 2.9 0.5 4.2 1.5 210 15 223 165 6.7 0 7 6.7 11/16/2005 22:10:00 3.3 0.5 4.2 1.9 3.1 0.5 4.2 1.5 3.1 0.5 4.2 1.9 195 7 197 165 6.6 0 7 6.5 11/16/2005 22:20:00 3.6 0.4 4.6 2.6 3.4 0.4 4.2 2.6 3.3 0.4 4.2 2.3 183 6 173 165 6.3 0.1 6.7 6 11/16/2005 22:30:00 3.1 0.4 4.2 2.3 2.8 0.4 3.8 2.3 2.7 0.3 3.4 1.9 171 7 164 165 5.8 0.1 6 5.7 11/16/2005 22:40:00 4 0.3 4.6 3.4 3.6 0.3 4.6 3 3.2 0.6 4.6 2.3 183 4 183 165 5.7 0 5.7 5.5 11/16/2005 22:50:00 3.7 0.4 4.6 2.6 3.5 0.4 4.2 2.6 3.2 0.5 4.2 1.9 192 8 184 165 5.7 0 5.7 5.5 11/16/2005 23:00:00 3.2 0.3 3.8 2.3 3.1 0.3 3.8 1.9 2.9 0.4 3.8 1.1 203 6 201 165 5.9 0.2 6.2 5.5 11/16/2005 23:10:00 3.2 0.3 4.2 2.6 3 0.3 4.2 2.3 3.1 0.4 4.2 2.3 207 5 205 165 6.3 0 6.5 6 11/16/2005 23:20:00 4.8 0.7 6.5 3 4.7 0.7 6.5 3 4.7 0.7 6.1 3 201 4 199 165 6.4 0 6.7 6.2 11/16/2005 23:30:00 5.8 0.7 7.2 3.8 5.8 0.8 7.2 4.2 5.8 0.9 7.6 3 201 6 200 165 6.6 0 7 6.2 11/16/2005 23:40:00 5.4 1 7.6 2.6 5.2 1 7.6 3 5.4 1.1 8 3 191 9 187 165 6.6 0 6.7 6.2 11/16/2005 23:50:00 5.3 0.5 6.8 3.8 5.1 0.5 6.5 3.8 5.1 0.5 6.5 3.8 179 8 183 165 6.2 0.3 6.7 5.5 11/17/2005 00:00:00 5.6 0.5 6.8 4.2 5.3 0.5 6.5 4.2 5.3 0.6 6.8 3.8 173 6 179 165 5.6 0 5.7 5.5 11/17/2005 00:10:00 6 0.6 7.6 4.6 5.7 0.6 7.2 4.2 5.6 0.6 6.8 4.6 175 5 173 165 5.7 0 5.7 5.5 11/17/2005 00:20:00 5.3 0.5 6.5 4.6 4.9 0.5 6.1 4.2 5.1 0.5 6.5 4.2 178 3 179 165 5.8 0 6 5.5 11/17/2005 00:30:00 5.4 0.4 6.5 4.2 5.3 0.5 6.1 3.8 5.4 0.6 6.5 3.8 190 8 189 165 5.7 0 6 5.5 11/17/2005 00:40:00 5 0.4 6.1 4.2 4.9 0.4 5.7 3.8 5.2 0.4 6.1 4.2 186 5 196 165 5.7 0 6 5.7 11/17/2005 00:50:00 4.1 0.6 5.3 3 3.9 0.5 5.3 2.6 4.2 0.5 5.3 3 183 4 189 165 5.7 0 5.7 5.5 11/17/2005 01:00:00 4.6 0.6 6.1 3 4.3 0.6 6.5 3 4.4 0.5 5.7 3 175 6 179 165 5.6 0 5.7 5.5 11/17/2005 01:10:00 5.2 0.6 7.2 3.8 5.1 0.6 7.2 3.8 5.2 0.5 6.5 3.4 190 6 194 165 5.5 0 5.7 5.5 11/17/2005 01:20:00 6.9 1.2 9.5 4.2 6.9 1.3 9.5 4.2 6.9 1.3 9.9 3.8 195 6 196 165 5.4 0 5.7 5.2 11/17/2005 01:30:00 8.5 0.8 10.7 6.1 8.4 0.8 10.3 5.7 8.5 1 10.7 6.5 190 6 196 165 5.4 0 5.5 5.2 11/17/2005 01:40:00 7.8 0.8 9.5 6.1 7.7 0.8 9.1 5.7 7.7 1 9.9 4.9 191 6 189 165 5.4 0 5.5 5.5 11/17/2005 01:50:00 7.9 0.8 10.3 5.3 7.9 0.7 9.9 5.7 8 0.8 9.5 5.3 188 7 194 165 5.4 0 5.5 5.2 11/17/2005 02:00:00 6.3 1.1 9.1 3.4 6.3 1.1 8.8 3.4 6.4 1.1 8.4 3.8 194 8 208 165 5.2 0 5.5 5.2 11/17/2005 02:10:00 4.9 1.1 7.6 2.3 4.8 1.1 7.6 2.3 4.7 1 6.8 2.6 197 9 194 165 5.2 0 5.5 5 11/17/2005 02:20:00 7.5 0.6 8.8 5.7 7.3 0.6 8.4 5.7 7.5 0.7 9.1 5.3 187 5 187 165 5.3 0 5.5 5 11/17/2005 02:30:00 7.3 0.6 8.8 5.7 7.1 0.6 8.8 5.7 7.4 0.6 9.1 5.7 187 5 191 165 5.3 0 5.5 5.2 11/17/2005 02:40:00 7 0.5 8.4 5.7 6.8 0.5 8.4 5.7 7 0.6 8.8 5.3 187 4 187 165 5.2 0 5.5 5.2 11/17/2005 02:50:00 6.6 0.4 7.6 4.9 6.5 0.4 7.2 4.9 6.8 0.5 7.6 5.3 191 4 184 165 5.2 0 5.5 5 11/17/2005 03:00:00 5.1 0.7 7.2 3.4 5 0.7 7.6 3.4 5.1 0.7 6.8 3.4 192 7 205 165 5.2 0 5.5 5.2 11/17/2005 03:10:00 5.5 0.6 7.2 4.2 5.4 0.6 7.2 4.2 5.5 0.7 7.2 3.8 189 4 190 165 5.2 0 5.2 5 11/17/2005 03:20:00 5.7 0.4 6.8 4.9 5.6 0.4 6.5 4.9 5.6 0.4 6.8 4.6 193 3 193 165 5.2 0 5.2 4.8 11/17/2005 03:30:00 5.6 0.4 6.5 4.6 5.3 0.4 6.5 4.6 5.4 0.4 6.8 4.6 186 5 194 165 5.1 0 5.2 5 11/17/2005 03:40:00 4.1 0.5 5.7 2.6 3.8 0.5 4.9 2.6 4 0.5 5.3 2.6 175 10 178 165 5 0 5.2 4.8 11/17/2005 03:50:00 4.7 0.6 6.1 3.4 4.4 0.7 5.7 3 4.5 0.7 6.1 3 179 5 184 165 5 0 5 4.8 11/17/2005 04:00:00 5.5 0.5 6.5 4.2 5.3 0.5 6.5 4.2 5.3 0.5 6.8 3.8 181 11 182 165 5 0 5 4.8 11/17/2005 04:10:00 5.9 0.4 6.8 4.9 5.9 0.4 7.2 4.6 5.8 0.5 6.8 4.6 206 6 208 165 5.1 0.1 5.2 5 11/17/2005 04:20:00 6.5 1 8.4 3.8 6.5 1 8.8 3.8 6.3 1 8.4 3.8 206 9 198 165 5.2 0 5.2 5 11/17/2005 04:30:00 7 0.9 8.8 5.3 7 0.8 8.8 5.3 7.2 1 9.5 5.3 203 9 191 165 5.1 0 5.2 4.8 11/17/2005 04:40:00 5.7 0.4 6.5 4.6 5.7 0.4 6.5 4.6 5.7 0.4 6.5 4.9 206 6 207 165 5 0 5 4.8 11/17/2005 04:50:00 4.9 0.6 6.1 3.4 4.7 0.6 6.1 3 4.8 0.6 6.1 3 188 5 193 165 4.9 0 5 4.8 11/17/2005 05:00:00 5 0.3 5.7 3.8 4.8 0.3 5.3 3.8 4.9 0.4 5.7 3.8 186 4 188 165 4.9 0 5 4.8 11/17/2005 05:10:00 4.7 0.3 5.3 3.8 4.4 0.3 5.3 3.8 4.6 0.3 5.3 3.8 172 6 180 165 4.9 0 5 4.8 11/17/2005 05:20:00 4.5 0.6 5.7 3 4.2 0.6 5.3 2.6 4.3 0.6 5.7 2.3 176 11 165 165 4.8 0 5 4.8 11/17/2005 05:30:00 2.6 0.8 4.2 0.7 2.3 0.9 3.8 0.4 2.3 1 4.2 0.4 184 19 185 165 4.7 0 4.8 4.8 11/17/2005 05:40:00 3.1 0.5 4.2 1.5 2.9 0.6 4.2 0.7 2.5 0.5 4.2 0.7 205 10 226 165 4.9 0 5 4.8 11/17/2005 05:50:00 3.3 0.3 4.2 2.3 3.2 0.4 3.8 1.9 3.1 0.4 3.8 1.9 197 7 202 165 4.9 0 5 4.8 11/17/2005 06:00:00 3.1 0.7 4.9 1.5 2.9 0.6 4.6 1.1 3 0.6 4.6 1.9 189 12 192 165 4.8 0 5 4.5 11/17/2005 06:10:00 3.1 0.4 4.2 1.9 2.9 0.4 4.2 1.5 3 0.4 4.2 1.5 183 8 182 165 4.7 0 5 4.5 11/17/2005 06:20:00 4.4 0.5 5.3 2.6 4.3 0.6 5.3 2.6 4.3 0.6 5.7 2.6 188 8 197 165 4.6 0 4.8 4.5 11/17/2005 06:30:00 4.6 0.4 5.7 3.4 4.5 0.4 5.7 3.4 4.3 0.5 5.7 3.4 193 4 193 165 4.6 0 4.8 4.5 11/17/2005 06:40:00 4.1 0.7 5.7 2.3 4 0.7 5.7 1.9 3.7 0.8 5.3 1.5 191 7 195 165 4.4 0 4.8 4.3 11/17/2005 06:50:00 4.2 0.5 5.3 2.6 4.1 0.5 5.3 2.6 3.9 0.6 5.3 2.3 198 5 194 165 4.4 0 4.5 4.3 11/17/2005 07:00:00 4.9 0.7 6.5 2.6 5 0.7 6.5 2.6 4.6 0.7 6.1 3 208 8 211 165 4.3 0 4.5 4.3 11/17/2005 07:10:00 5.6 0.6 7.2 3.8 5.6 0.7 7.2 4.2 5.2 0.6 7.2 3.8 208 5 205 165 4.2 0 4.5 4 11/17/2005 07:20:00 4.6 0.8 6.8 3 4.7 0.8 6.8 3 4.5 0.8 6.5 2.6 213 10 207 165 4.1 0 4.3 4 11/17/2005 07:30:00 3.7 0.3 4.6 3 3.7 0.4 4.6 2.6 3.7 0.4 4.6 3 239 5 232 165 4 0 4.3 3.8 11/17/2005 07:40:00 2.9 0.8 4.6 1.5 3.3 0.5 4.6 1.9 3.1 0.5 4.2 1.9 250 9 243 165 4.1 0 4.3 4 11/17/2005 07:50:00 2.8 0.4 3.8 1.9 2.9 0.3 3.8 2.3 2.4 0.4 3 1.1 294 11 313 165 4.1 0 4.3 4 11/17/2005 08:00:00 2.8 0.4 3.8 1.9 2.8 0.3 3.8 1.9 2.5 0.5 3.4 1.1 308 3 311 165 4.1 0 4.3 4 11/17/2005 08:10:00 1.5 0.6 2.6 0.7 1.5 0.6 2.6 0.4 1 0.5 1.9 0.4 292 10 303 165 4.1 0 4.3 3.8 11/17/2005 08:20:00 2.2 1 4.6 0.4 2.1 1 4.9 0.4 2 1.1 4.2 0.4 228 14 214 165 4.2 0 4.5 4.3 11/17/2005 08:30:00 3.6 0.5 4.6 2.3 3.6 0.5 4.6 2.3 3.5 0.5 4.6 2.3 214 5 212 165 4.5 0 4.8 4.5 11/17/2005 08:40:00 3.4 0.3 4.2 2.6 3.4 0.3 4.2 2.6 3.2 0.4 4.6 2.3 204 4 206 165 4.4 0 4.5 4.3 11/17/2005 08:50:00 3.6 0.4 4.6 2.3 3.6 0.4 4.6 2.6 3.2 0.4 4.2 1.9 215 5 224 165 4.4 0 4.5 4.3 11/17/2005 09:00:00 2.8 0.6 4.2 1.5 2.8 0.6 4.2 1.5 2.7 0.6 3.8 1.5 222 7 219 165 4.4 0 4.5 4.3 11/17/2005 09:10:00 1.9 0.3 2.6 1.1 1.9 0.3 2.6 1.1 1.8 0.3 2.6 1.1 217 6 214 165 4.4 0 4.5 4.3 11/17/2005 09:20:00 2.2 0.3 2.6 1.5 2.1 0.3 2.6 1.1 2.1 0.5 2.6 1.1 208 4 212 165 4.4 0 4.5 4 11/17/2005 09:30:00 2.6 0.5 3.4 1.5 2.4 0.5 3.4 1.5 2.2 0.5 3.4 1.1 222 13 230 165 4.3 0 4.5 4 11/17/2005 09:40:00 2.1 0.5 3 0.7 2.2 0.6 3 0.7 2.6 0.4 3.4 1.5 250 5 249 165 4.5 0 4.8 4.3 11/17/2005 09:50:00 2 0.7 3.4 0.7 1.9 0.7 3 0.4 2.3 0.5 3.4 1.5 226 11 206 165 4.6 0 4.8 4.3 11/17/2005 10:00:00 3.1 0.3 3.8 2.3 3 0.4 3.8 2.3 3.2 0.4 3.8 2.3 192 15 205 165 4.6 0 4.8 4.3 11/17/2005 10:10:00 2.6 0.3 3.4 1.9 2.4 0.3 3.4 1.5 2.5 0.3 3.4 1.9 160 3 159 165 4.3 0 4.5 4.3 11/17/2005 10:20:00 2.2 0.3 3 1.5 2 0.3 2.6 1.1 1.7 0.4 2.6 0.7 169 7 174 165 4.6 0.2 5.2 4.3 11/17/2005 10:30:00 1.9 0.5 3.4 0.7 1.8 0.5 3.4 0.4 1.5 0.6 3.4 0.4 190 17 206 165 5.7 0.3 6.2 5 11/17/2005 10:40:00 2.7 0.4 4.2 1.9 2.7 0.5 4.2 1.5 2.8 0.4 3.8 1.9 194 9 175 165 6.2 0 6.2 6 11/17/2005 10:50:00 2.6 0.4 3.4 1.9 2.6 0.4 3.4 1.5 2.2 0.4 3.4 1.1 214 10 187 165 6.6 0.2 7 6 11/17/2005 11:00:00 2.7 0.3 3.4 1.9 2.7 0.3 3.4 1.9 2.6 0.4 3.8 1.1 216 16 227 165 6.9 0 7 6.5 11/17/2005 11:10:00 2.1 0.5 3.8 0.7 1.9 0.6 3.4 0.4 1.8 0.4 3 0.7 183 22 214 165 6.8 0 7 6.5 11/17/2005 11:20:00 3.4 0.8 4.9 1.1 3.4 0.8 4.9 0.4 3.1 0.8 4.9 1.1 208 18 219 165 6.8 0 7 6.7 11/17/2005 11:30:00 2.8 0.5 4.2 1.1 2.8 0.6 4.2 1.1 2.6 0.6 3.8 1.1 224 14 197 165 6.9 0 7.3 6.5 11/17/2005 11:40:00 2.9 0.3 3.4 1.5 2.9 0.3 3.4 1.9 2.9 0.4 3.4 1.5 225 9 212 165 6.9 0 7.3 6.5 11/17/2005 11:50:00 1.9 0.8 3 0.4 2 0.7 3 0.4 2.2 0.6 3 0.7 231 7 227 165 7.3 0 7.5 6.7 11/17/2005 12:00:00 1.7 0.9 3.4 0.4 1.7 0.9 3.8 0.4 2 0.8 3.8 0.4 207 13 210 165 7.7 0.2 8 7.3 11/17/2005 12:10:00 3.3 0.8 5.3 1.5 3.3 0.8 5.3 1.5 3.5 0.8 4.9 1.9 171 24 164 165 7.1 0.2 7.5 6.5 11/17/2005 12:20:00 2.6 0.8 4.6 0.7 2.6 0.8 4.6 0.7 2.6 0.7 4.6 1.5 176 22 159 165 6.7 0 7 6.2 11/17/2005 12:30:00 1.6 0.4 2.6 0.4 1.6 0.4 2.6 0.4 1.7 0.4 2.6 0.7 214 12 224 165 7.4 0.3 8 6.7 11/17/2005 12:40:00 1.6 0.8 3.4 0.4 1.7 0.7 3.4 0.4 1.8 0.6 3 0.4 220 22 191 165 7.8 0 8.3 7.5 11/17/2005 12:50:00 1.5 0.7 2.6 0.4 1.5 0.6 2.6 0.4 1.6 0.7 3 0.4 170 22 183 165 8.1 0.3 8.5 7.5 11/17/2005 13:00:00 2.6 0.9 4.9 1.1 2.6 0.9 4.9 1.1 2.6 0.8 4.6 1.1 205 14 205 165 7.9 0.3 8.8 7 11/17/2005 13:10:00 3.4 0.5 4.6 1.9 3.4 0.5 4.6 1.9 3.4 0.5 4.6 1.9 203 11 218 165 6.9 0.3 7.8 6.2 11/17/2005 13:20:00 3.4 0.7 4.9 1.5 3.4 0.7 4.9 1.5 3.3 0.7 4.9 1.5 195 13 197 165 6.4 0.1 6.7 6 11/17/2005 13:30:00 4.6 0.9 6.8 3 4.7 1 6.8 2.6 4.4 0.9 6.8 3 221 9 208 165 6.7 0.3 7.3 6.2 11/17/2005 13:40:00 5.1 0.8 7.6 3.4 5.1 0.8 7.6 3 5.2 0.9 8 3.4 201 9 213 165 7 0 7.3 6.7 11/17/2005 13:50:00 4.3 0.5 5.7 3 4.4 0.5 5.7 3 4.3 0.5 5.7 3 215 14 189 165 6.8 0 7 6.5 11/17/2005 14:00:00 3.6 0.6 4.9 2.3 3.6 0.6 4.9 2.3 3.6 0.8 6.1 1.9 221 13 223 165 7.1 0 7.3 6.7 11/17/2005 14:10:00 2.9 0.6 4.6 1.9 3 0.6 4.9 1.9 3 0.6 4.6 1.5 217 14 225 165 7.1 0 7.3 6.7 11/17/2005 14:20:00 2.1 0.5 3 0.4 2.1 0.5 3 0.7 2.1 0.5 3 0.7 227 15 224 165 7 0.2 7.5 6.5 11/17/2005 14:30:00 2.1 0.4 3.8 0.7 2.2 0.4 3.8 1.1 2.1 0.4 3.8 1.1 233 11 249 165 6.5 0 6.7 6.2 11/17/2005 14:40:00 3.4 0.4 4.2 2.3 3.4 0.4 4.6 2.6 3.3 0.4 4.2 2.6 240 7 242 165 5.9 0.2 6.5 5.7 11/17/2005 14:50:00 4 0.5 5.3 3 4.1 0.5 5.3 3 4 0.5 5.3 3 225 7 213 165 5.6 0 5.7 5.5 11/17/2005 15:00:00 3.7 0.6 4.9 2.3 3.8 0.6 5.3 2.3 3.6 0.6 4.9 2.3 218 8 221 165 5.6 0.1 6 5.2 11/17/2005 15:10:00 3.9 0.7 5.3 2.6 4 0.7 5.3 2.6 3.8 0.7 5.7 2.3 218 8 219 165 5.9 0.2 6.2 5.5 11/17/2005 15:20:00 4 0.4 5.3 3 4.1 0.4 5.3 3 4 0.5 5.3 2.6 217 7 215 165 6.3 0 6.5 6 11/17/2005 15:30:00 3.4 0.7 4.6 1.9 3.5 0.8 4.9 1.9 3.3 0.7 4.9 1.9 223 10 212 165 6.2 0 6.7 6 11/17/2005 15:40:00 2.1 0.4 3 1.1 2.3 0.3 3 1.5 2.2 0.4 3.4 1.5 270 16 246 165 5.8 0.3 6.2 5 11/17/2005 15:50:00 2.2 0.5 3.8 0.7 2.5 0.5 3.4 1.5 2.4 0.5 3.4 0.7 251 12 245 165 5.2 0 5.5 5 11/17/2005 16:00:00 2.2 0.4 3 1.1 2.6 0.3 3.4 1.5 2.6 0.3 3.4 1.5 267 10 248 165 5 0.3 5.7 4.5 11/17/2005 16:10:00 3.2 0.4 4.2 2.3 3.3 0.4 4.2 2.3 3.4 0.4 4.2 2.3 284 4 275 165 4.1 0.1 4.5 3.8 11/17/2005 16:20:00 3 0.5 3.8 1.9 3.3 0.4 4.2 2.3 3.3 0.4 4.2 2.3 272 5 276 165 3.8 0.1 4.3 3.5 11/17/2005 16:30:00 1.7 0.9 3.4 0.4 2 1 3.8 0.4 2.3 1 3.8 0.4 256 17 275 165 3.5 0 3.8 3.3 11/17/2005 16:40:00 2.7 1 4.6 0.4 2.9 0.9 4.6 0.7 2.9 1 4.6 0.4 270 15 277 165 3.8 0.3 4.3 3.3 11/17/2005 16:50:00 2.3 0.9 4.6 0.7 2.4 0.8 4.6 0.7 2.1 0.8 4.2 0.7 292 12 290 165 3 0 3.3 2.8 11/17/2005 17:00:00 2 0.5 3.4 0.4 2.2 0.5 3.4 0.4 2.1 0.5 3.8 0.4 252 18 210 165 3.2 0 3.5 2.8 11/17/2005 17:10:00 2.8 0.5 3.8 1.9 2.9 0.4 4.2 1.9 2.9 0.5 4.2 1.9 205 12 193 165 3.5 0.1 3.8 3.3 11/17/2005 17:20:00 2.8 0.4 4.2 1.9 2.8 0.4 4.2 1.9 2.9 0.5 4.9 1.9 203 9 185 165 3.7 0.1 3.8 3.5 11/17/2005 17:30:00 2.4 0.4 3.4 1.1 2.4 0.4 3.8 1.5 2.3 0.4 3 1.1 214 12 190 165 3.6 0 3.8 3.5 11/17/2005 17:40:00 1.8 0.5 3 0.4 1.9 0.5 3 0.4 1.8 0.5 3 0.4 200 17 219 165 3.5 0 3.8 3.3 11/17/2005 17:50:00 1.1 0.4 2.3 0.4 1.1 0.4 2.3 0.4 1 0.4 1.9 0.4 220 15 225 165 3.5 0 3.5 3.3 11/17/2005 18:00:00 0.9 0.5 2.3 0.4 0.9 0.5 1.9 0.4 1 0.6 2.3 0.4 197 9 185 165 3.3 0 3.5 3.3 11/17/2005 18:10:00 1.7 0.3 3 1.1 1.6 0.3 2.6 0.7 1.7 0.2 2.6 1.1 167 6 160 165 3.3 0 3.5 3.3 11/17/2005 18:20:00 3.2 0.5 4.2 1.9 3.2 0.6 4.6 1.9 3 0.5 4.2 1.5 137 15 142 165 3 0.1 3.3 2.8 11/17/2005 18:30:00 4.1 0.5 5.3 3 4 0.5 5.3 3 4.1 0.6 5.7 2.3 158 9 165 165 3.2 0 3.5 2.6 11/17/2005 18:40:00 3.2 0.4 4.2 1.9 3.1 0.4 4.2 1.9 3.2 0.4 4.2 2.3 153 7 155 165 3.2 0 3.3 3 11/17/2005 18:50:00 2.7 0.5 3.8 1.5 2.7 0.6 3.8 1.5 2.6 0.5 3.8 1.5 136 13 129 165 3 0 3.3 2.8 11/17/2005 19:00:00 1.8 0.9 3.8 0.4 1.8 1 3.8 0.4 1.7 1 3.8 0.4 151 45 111 165 3 0 3.3 2.8 11/17/2005 19:10:00 2.1 0.7 3.4 0.4 2.1 0.7 3.4 0.4 2 0.7 3 0.4 152 29 109 165 3.1 0 3.3 3 11/17/2005 19:20:00 1.4 0.4 2.3 0.4 1.4 0.5 2.3 0.4 1.3 0.6 2.3 0.4 135 30 105 165 3 0 3.3 3 11/17/2005 19:30:00 0.8 0.5 1.9 0.4 0.8 0.5 2.3 0.4 0.8 0.4 1.9 0.4 156 94 191 165 3 0 3.3 2.8 11/17/2005 19:40:00 0.7 0.4 1.9 0.4 0.7 0.4 1.5 0.4 0.7 0.4 1.9 0.4 144 79 185 165 2.6 0 2.8 2.6 11/17/2005 19:50:00 0.7 0.4 1.9 0.4 0.7 0.5 1.9 0.4 0.7 0.4 1.9 0.4 64 29 102 165 2.6 0 2.8 2.6 11/17/2005 20:00:00 1.3 0.3 2.3 0.7 1.4 0.2 2.3 1.1 1.5 0.3 2.3 0.7 91 15 53 165 2.8 0 2.8 2.8 11/17/2005 20:10:00 1.4 0.8 2.6 0.4 1.4 0.8 2.6 0.4 1.6 0.8 2.6 0.4 55 8 53 165 2.7 0 2.8 2.6 11/17/2005 20:20:00 1.3 0.7 3 0.4 1.3 0.7 2.6 0.4 1.8 0.6 3.4 0.4 41 26 28 165 2.6 0.2 2.8 2.3 11/17/2005 20:30:00 1.6 0.5 2.6 0.4 1.7 0.6 2.6 0.4 1.6 0.6 2.6 0.4 93 10 96 165 2.4 0 2.6 2.3 11/17/2005 20:40:00 2.5 0.4 3.4 1.9 2.5 0.4 3.4 1.9 2.4 0.5 3.4 1.5 118 10 129 165 2.4 0 2.6 2.3 11/17/2005 20:50:00 3.1 0.3 3.8 2.6 3.1 0.3 3.8 2.3 3 0.3 3.8 1.9 126 7 128 165 2.4 0 2.6 2.3 11/17/2005 21:00:00 3.4 0.5 4.6 2.3 3.3 0.5 4.2 2.3 3.5 0.5 4.6 2.3 148 8 154 165 2.4 0 2.6 2.3 11/17/2005 21:10:00 3.1 0.4 3.8 1.9 3 0.4 3.8 1.5 3.2 0.4 4.2 1.9 150 12 151 165 2.5 0 2.8 2.3 11/17/2005 21:20:00 4.1 0.8 5.7 2.6 3.9 0.7 5.7 2.6 4.1 0.8 6.1 2.6 161 13 164 165 2.4 0 2.6 2.3 11/17/2005 21:30:00 5.5 0.8 7.2 3.4 5.4 0.7 7.2 3.4 5.5 0.7 7.2 3.4 168 8 174 165 2.4 0 2.6 2.3 11/17/2005 21:40:00 5.7 1 8.4 4.2 5.6 0.9 7.6 3.8 5.8 0.9 8 4.2 176 7 179 165 2.4 0 2.6 2.3 11/17/2005 21:50:00 6.9 1 8.8 4.6 6.8 1 8.4 4.2 6.8 1 9.1 4.6 190 7 186 165 2.3 0 2.6 2.1 11/17/2005 22:00:00 8 0.8 9.9 6.5 8 0.8 9.9 6.5 8 0.6 9.9 6.8 190 6 197 165 2.4 0 2.6 2.3 11/17/2005 22:10:00 9.4 0.5 10.7 7.6 9.2 0.5 10.3 7.6 9.4 0.6 10.7 7.6 185 5 178 165 2.4 0 2.6 2.3 11/17/2005 22:20:00 8.8 0.7 10.7 6.8 8.4 0.7 10.3 6.8 8.8 0.7 10.3 6.8 173 4 182 165 2.4 0 2.6 2.1 11/17/2005 22:30:00 8.9 0.6 9.9 7.6 8.5 0.5 9.5 7.2 8.9 0.6 10.3 7.6 170 6 172 165 2.4 0 2.6 2.1 11/17/2005 22:40:00 7.2 0.7 9.1 5.3 6.8 0.7 8.8 5.3 7.2 0.7 9.5 5.7 171 4 169 165 2.5 0 2.6 2.3 11/17/2005 22:50:00 5.2 0.6 6.8 3.8 4.9 0.6 6.5 3.4 5.2 0.7 6.5 3.8 174 5 179 165 2.4 0 2.6 2.3 11/17/2005 23:00:00 5.1 0.7 6.8 3.8 4.8 0.6 6.8 3.4 5 0.7 6.8 3 169 5 165 165 2.3 0 2.6 2.1 11/17/2005 23:10:00 6.4 0.5 7.2 4.6 6.2 0.5 7.2 4.6 6.5 0.6 7.6 4.6 162 6 165 165 2.4 0 2.6 2.1 11/17/2005 23:20:00 7.2 1 9.5 4.9 7 1 9.1 4.6 7.4 1 9.9 5.3 158 6 161 165 2.4 0 2.6 2.1 11/17/2005 23:30:00 7.5 0.5 9.1 6.5 7.4 0.5 9.1 6.5 7.7 0.5 8.8 5.7 163 4 164 165 2.4 0 2.6 2.3 11/17/2005 23:40:00 6.8 0.5 8 5.3 6.7 0.5 7.6 5.3 6.9 0.6 8 5.3 162 7 162 165 2.4 0 2.6 2.1 11/17/2005 23:50:00 5.8 0.4 6.8 4.6 5.7 0.4 6.8 4.6 5.8 0.4 6.8 4.6 154 5 146 165 2.3 0 2.3 2.1 11/18/2005 00:00:00 6.3 1 8.8 4.2 6.3 1 8.8 4.2 6.3 1 8.8 4.2 149 8 153 165 2.3 0 2.6 2.3 11/18/2005 00:10:00 7.1 0.5 8 5.7 7.1 0.5 8 5.7 7.2 0.5 8 5.7 148 3 142 165 2.4 0 2.6 2.3 11/18/2005 00:20:00 5.8 0.4 6.8 4.9 5.9 0.4 6.8 4.9 5.9 0.5 6.8 4.2 146 4 146 165 2.5 0 2.6 2.3 11/18/2005 00:30:00 5.7 0.4 7.2 4.6 5.6 0.4 6.8 4.6 5.6 0.4 6.5 4.6 140 6 143 165 2.5 0 2.8 2.3 11/18/2005 00:40:00 5.8 0.7 7.6 4.2 5.7 0.7 7.6 4.2 5.5 0.7 7.6 4.2 139 7 148 165 2.6 0 2.8 2.3 11/18/2005 00:50:00 6.8 1 9.1 4.6 6.8 1 9.1 4.6 6.5 0.9 8.8 4.6 132 8 129 165 2.9 0 3 2.6 11/18/2005 01:00:00 9.4 0.8 11.8 6.5 9.4 0.8 11.8 6.8 9.2 0.8 11.5 6.5 135 5 148 165 3.1 0 3.5 2.8 11/18/2005 01:10:00 11.8 1.3 14.9 8.8 11.9 1.3 14.9 8.4 11.7 1.6 14.9 6.5 140 8 144 165 3.5 0 3.5 3.3 11/18/2005 01:20:00 14.1 1.2 16.8 11.1 14.2 1.2 16.8 11.5 14 1.4 17.2 9.9 141 6 137 165 3.6 0 3.8 3.3 11/18/2005 01:30:00 15 1.1 17.2 11.5 15.1 1.1 17.6 11.8 14.9 1.3 17.6 11.1 141 5 133 165 3.8 0 3.8 3.5 11/18/2005 01:40:00 13.4 1.4 17.9 10.3 13.5 1.4 18.3 10.3 13.1 1.5 16.8 8.4 134 7 129 165 3.8 0 4 3.5 11/18/2005 01:50:00 13.5 1.5 17.2 9.5 13.6 1.5 17.2 9.9 13.2 1.5 16.8 9.1 131 7 128 165 3.8 0 4 3.5 11/18/2005 02:00:00 12.2 1.5 15.6 9.1 12.3 1.5 15.6 9.1 12 1.7 16.1 7.6 132 7 135 165 4 0 4 3.8 11/18/2005 02:10:00 12.2 1.6 16.4 8.4 12.4 1.6 16.4 8 12 1.7 16.1 8 128 8 135 165 4 0 4.3 3.8 11/18/2005 02:20:00 13.1 1.4 16.4 8.8 13.2 1.4 16.8 9.1 12.7 1.5 16.4 8 130 7 131 165 4 0 4 3.5 11/18/2005 02:30:00 13.7 2.3 19.1 8.8 13.7 2.3 19.5 8.4 13.3 2.4 19.5 8.4 131 8 129 165 4.1 0 4.3 3.8 11/18/2005 02:40:00 15.1 1.5 18.7 11.8 15.1 1.5 18.7 11.5 14.9 1.7 18.7 10.7 140 8 131 165 4.1 0 4.3 3.8 11/18/2005 02:50:00 15.7 1.7 20.2 11.5 15.8 1.7 20.2 11.5 15.5 1.8 22.1 11.5 137 6 140 165 4.1 0 4.5 4 11/18/2005 03:00:00 15.6 1.7 20.2 11.1 15.6 1.8 20.2 11.5 15.1 1.8 20.2 10.3 135 8 121 165 4.1 0 4.3 4 11/18/2005 03:10:00 15.7 1.7 20.6 11.5 15.8 1.7 21 11.5 15.3 2.2 19.9 9.5 131 8 132 165 4.1 0 4.3 4 11/18/2005 03:20:00 13.8 2.1 18.7 8.8 13.9 2.1 19.1 9.5 13.5 2.1 18.7 8.4 128 8 117 165 4.3 0 4.5 4 11/18/2005 03:30:00 14.3 2.3 19.5 9.1 14.5 2.3 19.9 9.1 14.1 2.2 21.4 9.1 129 10 121 165 4.3 0 4.5 4 11/18/2005 03:40:00 13.4 1.5 17.9 8 13.6 1.5 18.7 8.8 13 1.7 17.9 8.8 124 7 118 165 4.4 0 4.5 4 11/18/2005 03:50:00 13 2.6 18.7 7.2 13.1 2.6 19.1 7.6 12.6 2.5 18.7 8 127 8 106 165 4.4 0 4.5 4.3 11/18/2005 04:00:00 13.4 1.8 17.6 9.5 13.6 1.9 17.9 9.9 13.2 2 17.6 9.1 128 9 121 165 4.6 0 4.8 4.3 11/18/2005 04:10:00 12.2 1.9 16.4 8 12.3 1.9 17.2 8.4 11.9 1.9 16.1 7.2 130 9 137 165 4.7 0 4.8 4.3 11/18/2005 04:20:00 14.6 1.8 19.1 9.1 14.7 1.8 19.5 9.1 14.1 2 19.1 8.8 130 9 135 165 4.9 0 5 4.5 11/18/2005 04:30:00 15 1.8 20.2 9.5 15.1 1.8 20.6 9.5 14.5 2.2 21 9.1 134 8 137 165 5.1 0 5.2 4.8 11/18/2005 04:40:00 16.9 1.9 21.4 11.8 16.9 1.9 21.4 11.8 16.4 2 21.8 11.5 137 7 130 165 5.2 0 5.5 5 11/18/2005 04:50:00 15.8 1.7 21.4 11.8 15.9 1.7 21.4 11.8 15.4 1.7 19.9 11.1 134 7 145 165 5.4 0 5.7 5.2 11/18/2005 05:00:00 17.4 1.7 21.8 11.1 17.4 1.7 22.1 11.8 16.9 2.1 22.6 9.9 140 8 144 165 5.7 0.1 6 5.5 11/18/2005 05:10:00 17.7 2 22.1 12.2 17.8 2 22.1 12.2 17.2 2.1 22.6 12.6 140 8 137 165 6 0 6.2 5.7 11/18/2005 05:20:00 17 1.9 23.3 13 17 1.9 23.3 13.3 16.6 2 22.1 12.2 140 7 140 165 6.2 0 6.5 6 11/18/2005 05:30:00 15.5 1.7 21.8 10.7 15.5 1.6 22.1 10.7 15 1.7 21.8 10.3 147 6 148 165 6.4 0 6.5 6.2 11/18/2005 05:40:00 13.3 1.3 16.4 9.9 13.4 1.3 16.1 10.3 12.9 1.3 16.1 9.1 146 3 147 165 6.4 0 6.7 6.2 11/18/2005 05:50:00 11.9 0.7 13.7 9.9 12 0.7 14.1 9.5 11.5 0.9 13.7 8.8 149 4 154 165 6.4 0 6.7 6.2 11/18/2005 06:00:00 11.5 0.6 13 9.5 11.4 0.6 13.3 9.5 11.3 0.7 13.7 9.5 151 3 152 165 6.4 0 6.7 6.2 11/18/2005 06:10:00 11.6 0.7 14.5 9.5 11.5 0.7 14.1 9.9 11.4 0.7 13.7 9.5 151 3 157 165 6.4 0 6.7 6.2 11/18/2005 06:20:00 14.3 1.3 16.8 11.1 14.2 1.3 16.8 10.7 14 1.3 16.8 11.1 151 3 150 165 6.4 0 6.7 6.2 11/18/2005 06:30:00 13.8 0.9 16.1 11.5 13.7 0.9 16.1 11.5 13.8 1 16.4 11.8 152 3 152 165 6.4 0 6.7 6.2 11/18/2005 06:40:00 13 0.7 14.9 11.1 12.9 0.8 14.5 11.1 13 0.7 14.9 10.7 150 4 151 165 6.5 0 6.7 6.2 11/18/2005 06:50:00 13.9 1 16.4 11.8 13.9 1 16.1 11.8 13.7 1 16.4 11.8 149 4 152 165 6.5 0 6.7 6.2 11/18/2005 07:00:00 15.1 0.8 17.2 13 15.1 0.8 17.2 13 14.8 1 17.2 11.8 150 11 151 165 6.5 0 7 6.2 11/18/2005 07:10:00 13.3 0.8 15.3 10.7 13.3 0.8 15.3 11.1 13.1 1 15.6 9.9 149 5 154 165 6.3 0 6.5 6.2 11/18/2005 07:20:00 14.7 1 17.2 11.1 14.8 1 17.2 11.1 14.5 1 17.2 11.1 150 3 150 165 6.4 0 6.7 6 11/18/2005 07:30:00 13.4 1.4 16.8 10.3 13.5 1.3 16.8 10.3 13.3 1.4 16.8 10.3 152 4 141 165 6.2 0 6.5 6 11/18/2005 07:40:00 12.8 0.6 14.5 10.7 12.8 0.6 14.1 10.7 12.8 0.8 14.1 9.5 153 3 152 165 5.9 0.1 6 5.7 11/18/2005 07:50:00 13.4 0.7 15.3 11.8 13.5 0.7 15.3 12.2 13.4 0.8 15.6 10.7 151 3 151 165 5.6 0 5.7 5.5 11/18/2005 08:00:00 14.7 1 17.6 12.6 14.8 0.9 17.6 12.6 14.5 1.2 17.2 11.1 150 4 147 165 5.9 0 6.2 5.5 11/18/2005 08:10:00 16.2 1.1 18.7 12.6 16.2 1.1 19.1 13 15.8 1.3 19.1 11.8 148 4 152 165 6.2 0 6.2 6 11/18/2005 08:20:00 17.5 1 19.9 14.5 17.6 1 19.9 14.5 17.2 1.1 19.9 14.5 144 4 142 165 6.2 0 6.2 6 11/18/2005 08:30:00 17.5 1.5 20.6 14.5 17.6 1.4 21 14.5 17.1 1.7 21.4 12.6 145 5 154 165 6 0 6.2 5.7 11/18/2005 08:40:00 17.6 1.2 20.6 13.7 17.6 1.2 20.6 13.7 17.1 1.4 20.6 13 145 5 141 165 6.1 0 6.2 5.7 11/18/2005 08:50:00 16.5 1.2 19.5 13.7 16.6 1.1 19.9 13.3 16.1 1.5 19.5 11.8 145 5 145 165 6.1 0 6.2 5.7 11/18/2005 09:00:00 15.6 0.9 17.6 11.8 15.7 0.9 17.6 12.2 15.4 1 17.9 12.6 146 4 145 165 6.1 0 6.2 6 11/18/2005 09:10:00 14.5 1.1 17.6 11.5 14.5 1.1 17.6 11.5 14 1.3 18.3 9.9 146 5 148 165 6.1 0 6.2 6 11/18/2005 09:20:00 15.3 1 18.3 12.2 15.4 1 18.3 12.2 14.8 1.1 17.9 11.5 142 6 133 165 6.2 0 6.2 6 11/18/2005 09:30:00 16.2 1.3 19.1 13.3 16.2 1.3 19.1 13 16.1 1.3 19.5 11.5 142 5 143 165 6.1 0 6.2 6 11/18/2005 09:40:00 17.4 2.8 24.4 11.5 17.5 2.8 24.4 11.8 17.1 2.8 24.4 10.3 139 8 146 165 6 0 6 5.7 11/18/2005 09:50:00 18.1 2.5 24.4 13 18 2.5 24.4 13 18 2.5 25.2 13 151 5 147 165 5.6 0 6 5.5 11/18/2005 10:00:00 12.5 1.1 15.3 9.5 12.5 1.1 15.3 9.1 12.2 1.2 15.3 9.1 147 4 145 165 5.3 0 5.5 5.2 11/18/2005 10:10:00 11.9 1.1 15.3 9.1 11.9 1.1 15.3 9.9 11.7 1.2 15.6 9.1 145 5 151 165 5.2 0 5.5 5.2 11/18/2005 10:20:00 12.1 1.6 16.8 9.5 12.2 1.5 16.8 9.9 12.1 1.7 17.6 8 141 6 146 165 5.2 0 5.5 5.2 11/18/2005 10:30:00 13.5 1.2 16.4 9.9 13.5 1.2 16.4 9.9 13.4 1.3 16.4 9.5 145 5 148 165 5.2 0 5.5 5.2 11/18/2005 10:40:00 13.4 1.2 16.1 10.3 13.5 1.2 16.4 10.3 13.1 1.5 16.4 8.8 145 6 145 165 5.4 0 5.5 5.2 11/18/2005 10:50:00 14.3 1.1 16.8 10.7 14.4 1.1 16.8 10.7 14.1 1.3 17.2 9.9 145 6 150 165 5.2 0 5.2 5 11/18/2005 11:00:00 12.1 1.5 14.9 8.8 12.2 1.4 14.9 9.1 11.9 1.7 14.9 7.6 146 5 148 165 5.2 0 5.2 5 11/18/2005 11:10:00 11.3 1 13.7 8.8 11.3 1 13.7 9.1 10.9 1.2 13.7 8 143 5 147 165 5.2 0 5.5 5 11/18/2005 11:20:00 12.2 1.1 16.1 9.5 12.2 1.1 16.1 9.5 12 1.2 14.5 8.8 143 7 130 165 5.2 0 5.5 5 11/18/2005 11:30:00 12.3 1.1 14.9 10.3 12.3 1.1 14.9 9.9 12.2 1.1 15.3 9.5 142 7 133 165 5.3 0 5.5 5.2 11/18/2005 11:40:00 12.8 1.3 15.6 9.5 12.8 1.3 16.1 9.5 12.7 1.3 16.4 9.1 140 5 139 165 5.4 0 5.5 5.2 11/18/2005 11:50:00 10 1.4 13.7 6.5 10.1 1.4 13.7 6.5 9.7 1.5 14.5 6.5 139 8 137 165 5.4 0 5.5 5.2 11/18/2005 12:00:00 12.6 1.1 15.3 9.9 12.7 1.1 14.9 9.9 12.2 1.2 15.3 8.8 135 7 134 165 5.5 0 5.5 5.2 11/18/2005 12:10:00 12.6 1.2 15.6 9.5 12.6 1.2 15.6 9.9 12.2 1.3 15.3 9.1 137 7 137 165 5.5 0 5.7 5.2 11/18/2005 12:20:00 10.6 1.2 14.1 8.4 10.7 1.2 14.9 8.4 10.3 1.2 13.7 6.5 134 9 128 165 5.6 0 5.7 5.2 11/18/2005 12:30:00 11.2 1.1 14.1 8 11.2 1.2 14.1 8 10.7 1.4 14.1 6.8 130 8 137 165 5.6 0 5.7 5.5 11/18/2005 12:40:00 11.3 1 13.7 8 11.4 1 13.7 8 10.9 1.2 14.1 7.2 134 8 132 165 5.7 0 5.7 5.7 11/18/2005 12:50:00 9.8 1.3 13 7.2 9.9 1.3 13.7 6.8 9.6 1.2 13 6.5 137 8 121 165 5.7 0 5.7 5.5 11/18/2005 13:00:00 8.8 1 11.5 4.9 8.8 1 11.5 5.7 8.4 1 10.7 5.3 135 9 124 165 5.7 0 6 5.7 11/18/2005 13:10:00 8.2 1.2 11.5 4.6 8.2 1.1 11.8 4.9 7.8 1.3 11.1 4.6 136 11 135 165 5.8 0 6 5.7 11/18/2005 13:20:00 8.3 1.2 10.7 5.3 8.3 1.2 11.1 5.3 8 1.3 11.1 4.9 135 11 144 165 5.8 0 6 5.7 11/18/2005 13:30:00 6.1 1.2 9.5 3.4 6 1.2 9.5 3 6 1.1 8.8 3.8 131 13 138 165 5.8 0 6 5.7 11/18/2005 13:40:00 2.5 0.9 4.6 0.4 2.4 0.9 4.2 0.4 2.5 0.8 4.6 0.4 136 13 133 165 5.7 0 5.7 5.7 11/18/2005 13:50:00 1.1 0.6 2.6 0.4 1 0.6 3 0.4 1 0.6 2.3 0.4 32 86 143 165 5.7 0 5.7 5.5 11/18/2005 14:00:00 2.3 0.8 3.8 1.1 2.2 0.8 3.8 0.7 2 0.4 3 0.7 302 4 297 165 5.6 0 5.7 5.5 11/18/2005 14:10:00 5.4 0.5 6.8 3.8 5.4 0.6 6.8 3.8 4.5 0.7 6.1 2.3 291 7 297 165 5.2 0.2 5.7 5 11/18/2005 14:20:00 7.1 0.6 8.4 5.7 7 0.6 8.4 5.3 5.3 0.9 7.6 3.4 303 4 305 165 5 0 5 5 11/18/2005 14:30:00 9.7 0.8 11.8 7.2 9.6 0.8 12.2 7.2 7.7 1 10.3 5.3 303 4 300 165 4.9 0 5 4.8 11/18/2005 14:40:00 12.3 1.1 14.5 9.1 12.2 1.1 14.5 9.1 9.8 1.4 13.7 6.5 303 4 298 165 4.8 0 4.8 4.8 11/18/2005 14:50:00 11.7 1.1 14.5 8.8 11.6 1.2 14.5 8.4 10 1.4 13.3 6.8 305 4 306 165 4.7 0 4.8 4.8 11/18/2005 15:00:00 12.5 1 15.3 9.5 12.4 1 15.3 9.5 10.9 1.3 14.5 7.6 305 4 302 165 4.7 0 4.8 4.5 11/18/2005 15:10:00 13.3 1 15.6 10.3 13.1 1 15.6 11.1 11.6 1.4 14.9 8 306 5 307 165 4.6 0 4.8 4.5 11/18/2005 15:20:00 12.5 1.1 15.3 9.9 12.4 1.1 15.6 9.9 10 1.3 14.1 6.8 303 5 290 165 4.7 0 5 4.5 11/18/2005 15:30:00 12.3 1 15.6 9.5 12.2 1 15.6 9.5 10 1.5 13 6.8 305 6 305 165 4.9 0 5 4.8 11/18/2005 15:40:00 11.4 1.6 15.6 8 11.3 1.6 15.6 8 10 1.1 13 7.6 308 7 305 165 4.8 0 5 4.5 11/18/2005 15:50:00 10.3 2 16.8 6.1 10.2 1.9 16.4 5.7 8.6 1.7 13.3 4.9 303 10 295 165 4.9 0 5 4.5 11/18/2005 16:00:00 12.3 1.5 16.4 7.6 12.1 1.6 16.1 7.2 9.9 1.5 13.7 5.7 294 8 307 165 4.9 0 5 4.8 11/18/2005 16:10:00 12 1.7 14.9 6.8 12 1.6 14.9 6.8 10.5 1.7 14.1 6.1 285 7 293 165 5.1 0 5.2 4.8 11/18/2005 16:20:00 10.6 2 14.9 6.1 11 1.8 14.9 7.2 10.4 1.8 14.9 6.5 277 8 280 165 5.1 0 5.2 4.8 11/18/2005 16:30:00 8.9 1.4 12.6 4.9 9.2 1.3 12.6 6.5 8.7 1.6 13 4.6 280 9 281 165 5 0 5 4.8 11/18/2005 16:40:00 10.4 1.4 13.7 5.3 10.5 1.3 13.7 6.8 9.5 1.5 13.3 4.9 284 7 289 165 4.9 0 5 4.8 11/18/2005 16:50:00 11.2 1 14.1 8.8 11.2 1 14.1 9.1 10.7 1.4 14.9 6.8 283 5 276 165 4.9 0 5 4.8 11/18/2005 17:00:00 12.1 1 14.5 9.5 12.1 1 14.5 9.5 11.6 1.7 14.9 6.1 283 4 277 165 4.7 0 4.8 4.5 11/18/2005 17:10:00 10 1.5 13.3 6.8 10 1.5 13.7 6.8 9.4 1.9 13.7 4.9 284 6 281 165 4.4 0 4.5 4.3 11/18/2005 17:20:00 8.9 0.8 10.7 6.1 8.9 0.8 10.3 5.3 7.9 1.3 11.1 4.6 285 6 283 165 4.3 0 4.5 4.3 11/18/2005 17:30:00 10.7 1 13.7 8.8 10.7 1 13.7 8.4 10 1.3 14.5 5.7 283 4 278 165 4.3 0.1 4.5 4 11/18/2005 17:40:00 9.2 0.8 10.7 6.1 9.3 0.8 10.7 6.8 9 0.9 11.1 7.2 279 5 281 165 4.4 0 4.5 4.3 11/18/2005 17:50:00 9.7 0.9 11.8 6.8 9.8 0.9 12.2 6.8 9.1 1.2 11.8 4.9 282 5 279 165 4.3 0 4.5 4.3 11/18/2005 18:00:00 9.9 1 11.8 6.1 10.1 0.9 12.2 7.2 9.5 1.1 12.2 6.5 278 6 278 165 4.1 0 4.3 4 11/18/2005 18:10:00 9.4 1.1 11.1 6.5 9.5 1.1 11.1 6.5 9.1 1.3 11.8 5.7 280 3 277 165 4.1 0 4.3 3.8 11/18/2005 18:20:00 7.7 0.9 9.1 4.9 7.8 0.8 9.5 5.7 6.9 1 9.5 4.2 283 7 290 165 4.1 0 4.3 3.8 11/18/2005 18:30:00 7.3 1 9.1 4.2 7.5 0.9 9.5 4.9 6.7 1.1 9.5 3.8 280 10 274 165 4.1 0 4.3 4 11/18/2005 18:40:00 6.6 1.1 10.3 3 7.5 1.3 10.7 4.9 7 1.2 9.9 3.8 270 11 285 165 4.4 0.1 4.8 4.3 11/18/2005 18:50:00 4.8 1.3 8.8 2.6 5.5 1.5 10.3 3 4.8 1.5 8.4 1.5 266 14 274 165 4.4 0.1 4.5 4.3 11/18/2005 19:00:00 5.1 1.1 7.6 1.9 5.1 1 7.2 2.3 4.5 1 6.8 2.3 283 15 277 165 4.1 0 4.5 3.8 11/18/2005 19:10:00 4.2 0.8 6.5 1.9 4.5 0.9 7.2 2.6 4.2 0.7 6.5 2.6 251 14 280 165 4.1 0 4.5 3.8 11/18/2005 19:20:00 4 0.6 5.7 2.6 4 0.6 5.7 2.6 3.9 0.6 5.7 2.6 236 8 235 165 4.3 0 4.5 4 11/18/2005 19:30:00 4.8 1.1 8 2.3 5.6 1.3 8.4 2.6 5.2 1.2 7.6 2.6 258 12 273 165 4.1 0 4.3 3.8 11/18/2005 19:40:00 7.6 1 10.3 4.9 7.8 0.8 10.3 5.7 6.8 1 9.9 4.2 283 9 277 165 3.9 0 4.3 3.8 11/18/2005 19:50:00 8.7 1.5 11.8 5.3 10.2 1.6 13.3 6.1 9.4 1.8 13 4.6 271 9 281 165 3.8 0 4 3.5 11/18/2005 20:00:00 9.2 0.9 12.2 6.8 9.5 1.1 12.6 6.5 9 1.2 11.8 6.1 281 6 268 165 3.6 0.1 3.8 3.5 11/18/2005 20:10:00 7 1.2 10.3 4.2 8 1 10.7 5.7 7.7 1.1 9.9 4.6 262 12 248 165 3.6 0 3.8 3.5 11/18/2005 20:20:00 7.4 1.5 11.8 4.2 8.1 1.4 14.1 4.9 7.5 1.4 13 4.6 250 9 255 165 3.5 0 3.8 3.3 11/18/2005 20:30:00 8.3 1.7 13 4.2 9.5 1.4 13 5.7 8.8 1.5 13 5.3 254 8 247 165 3.3 0.1 3.5 3 11/18/2005 20:40:00 6.8 1.3 10.3 3 7.5 1.3 10.3 4.2 7 1.2 9.9 3.8 249 9 244 165 3.2 0 3.3 3 11/18/2005 20:50:00 4.7 1.2 7.2 1.9 4.7 1.2 7.2 1.9 4.4 1.2 7.2 1.5 221 14 233 165 3 0 3.3 2.8 11/18/2005 21:00:00 1.6 1 4.6 0.4 1.6 1 4.6 0.4 1.2 0.9 3.8 0.4 225 38 186 165 2.6 0 2.8 2.6 11/18/2005 21:10:00 2 1.1 5.3 0.4 2.1 1.2 5.3 0.4 1.9 1.1 4.2 0.4 255 26 243 165 2.4 0 2.6 2.3 11/18/2005 21:20:00 3.3 0.8 5.7 1.5 3.5 0.8 5.7 1.9 3.2 0.8 5.3 1.1 246 14 234 165 2.5 0 2.8 2.3 11/18/2005 21:30:00 4.1 1 6.8 2.3 4.7 0.8 6.5 2.6 4.3 0.8 6.5 2.3 254 10 244 165 2.5 0 2.6 2.3 11/18/2005 21:40:00 4.2 1 6.5 1.9 4.5 0.8 6.5 2.6 4.2 0.8 6.1 2.6 246 12 240 165 2.6 0 2.8 2.3 11/18/2005 21:50:00 4.2 1.1 6.1 1.5 4.4 1 6.1 1.9 4.1 1 6.1 1.5 247 10 241 165 2.4 0 2.6 2.3 11/18/2005 22:00:00 2.8 1 5.7 0.4 3 1 5.3 0.4 2.5 1 5.3 0.4 240 16 249 165 2.3 0 2.6 2.1 11/18/2005 22:10:00 3.1 1.2 7.6 0.4 3.2 1.1 7.2 0.4 2.7 1.1 6.1 0.4 242 18 250 165 2 0.1 2.3 1.8 11/18/2005 22:20:00 6.5 1.5 9.1 1.9 6.8 1.5 9.1 2.3 6.4 1.7 9.9 2.3 233 18 251 165 2.1 0 2.3 1.8 11/18/2005 22:30:00 6.3 0.8 8 3.8 6.5 0.8 8.4 3.8 6.1 1 8.8 3.4 215 6 213 165 2 0.1 2.3 1.8 11/18/2005 22:40:00 7.5 1.2 9.5 4.2 7.7 1.2 9.9 4.2 7.2 1.2 9.9 4.2 209 5 200 165 1.9 0 1.8 1.8 11/18/2005 22:50:00 7.6 1 10.3 5.3 7.6 1.1 10.3 5.3 7.3 1.2 10.3 4.9 200 8 207 165 1.9 0 1.8 1.8 11/18/2005 23:00:00 9.2 0.8 11.1 7.2 9.2 0.8 11.1 7.2 9.2 0.8 11.1 6.5 200 5 206 165 1.8 0 1.8 1.6 11/18/2005 23:10:00 9.3 0.9 11.1 6.5 9.3 0.9 11.5 6.5 9.4 1 11.8 6.5 195 5 199 165 1.7 0 1.8 1.6 11/18/2005 23:20:00 7.9 1.1 10.7 5.3 7.9 1 10.3 4.9 7.9 1.1 11.1 4.9 190 6 186 165 1.6 0 1.6 1.4 11/18/2005 23:30:00 8.9 1.1 11.8 6.5 8.8 1.1 11.5 6.1 8.6 1.1 11.5 5.3 200 8 199 165 1.7 0 1.8 1.4 11/18/2005 23:40:00 8.6 1.2 11.5 5.7 8.6 1.2 11.8 5.7 8.4 1.3 11.8 5.3 202 9 203 165 1.7 0 1.8 1.4 11/18/2005 23:50:00 8.3 1.1 11.5 5.7 8.4 1.1 11.5 5.7 8 1.3 11.1 4.9 212 8 199 165 1.7 0 1.8 1.4 11/19/2005 00:00:00 7.1 1 9.9 4.2 7.1 1 9.9 4.2 7 1 9.5 4.2 213 10 215 165 1.6 0 1.8 1.4 11/19/2005 00:10:00 9.4 1.1 11.8 6.1 9.5 1.1 11.8 6.1 9.2 1.2 12.2 5.7 207 7 194 165 1.6 0 1.6 1.4 11/19/2005 00:20:00 8.3 0.9 10.3 5.7 8.3 0.9 10.3 6.1 8.1 1 10.7 5.7 203 7 210 165 1.5 0 1.6 1.4 11/19/2005 00:30:00 8.3 0.9 10.7 4.6 8.3 0.9 11.1 4.9 7.9 1.1 11.5 4.9 202 7 201 165 1.4 0 1.6 1.4 11/19/2005 00:40:00 7.6 0.9 9.5 4.9 7.6 0.9 9.5 4.9 7.3 1.1 9.5 4.6 204 7 207 165 1.4 0 1.6 1.4 11/19/2005 00:50:00 7.8 1 10.7 5.3 7.8 1 10.7 5.7 7.6 1 9.9 5.3 203 5 207 165 1.4 0 1.6 1.4 11/19/2005 01:00:00 7.3 0.9 9.1 5.3 7.3 0.9 9.1 5.3 7.1 1 9.5 4.6 202 6 208 165 1.4 0 1.6 1.4 11/19/2005 01:10:00 7.8 0.8 10.7 5.7 7.7 0.8 10.3 5.7 7.8 0.8 9.5 5.3 198 6 208 165 1.4 0 1.6 1.1 11/19/2005 01:20:00 6.6 0.7 8.8 4.9 6.6 0.7 8.8 4.9 6.5 0.8 8.8 4.6 198 7 203 165 1.2 0 1.4 1.1 11/19/2005 01:30:00 7.6 0.7 9.1 6.1 7.6 0.7 9.1 5.7 7.5 0.8 9.1 5.3 199 6 196 165 1.2 0 1.4 0.9 11/19/2005 01:40:00 8.3 1.1 10.7 6.1 8.3 1.2 11.1 5.7 8.2 1.2 11.5 4.9 203 6 205 165 1.2 0 1.4 1.1 11/19/2005 01:50:00 7.9 0.9 10.3 6.1 8 0.9 10.3 6.1 7.9 0.9 10.3 5.3 204 6 207 165 1.1 0 1.4 0.9 11/19/2005 02:00:00 8 1 11.1 5.3 8.1 1 10.7 5.3 7.7 1.1 10.3 4.6 205 6 201 165 1.1 0 1.4 0.9 11/19/2005 02:10:00 8.2 0.9 10.3 5.7 8.3 0.9 10.7 6.1 7.9 0.8 10.3 5.7 207 7 205 165 0.9 0 1.1 0.7 11/19/2005 02:20:00 8.3 1 11.1 5.7 8.4 1.1 11.5 6.1 8.1 1.2 11.5 4.9 206 7 209 165 0.9 0 1.1 0.9 11/19/2005 02:30:00 7.9 1 10.3 4.6 8 1 10.3 4.9 7.6 1.1 10.7 4.9 205 7 207 165 0.8 0 1.1 0.9 11/19/2005 02:40:00 8.1 0.9 10.3 6.1 8.2 1 10.7 5.7 7.8 1 9.9 4.9 206 6 211 165 0.8 0 0.9 0.9 11/19/2005 02:50:00 8.3 1 10.3 6.1 8.4 1 10.3 5.7 8.2 1 10.7 5.7 203 6 204 165 0.8 0 0.9 0.7 11/19/2005 03:00:00 7.8 1 10.3 5.7 7.8 1 10.3 5.3 7.6 1.2 10.3 4.6 200 7 196 165 0.8 0 0.9 0.7 11/19/2005 03:10:00 7.5 0.8 9.1 4.9 7.5 0.8 9.1 4.9 7.3 0.9 9.5 4.6 204 6 204 165 0.7 0 0.9 0.7 11/19/2005 03:20:00 6.6 0.8 8.8 4.9 6.6 0.8 9.1 4.9 6.3 0.9 8.8 4.2 206 5 213 165 0.6 0 0.9 0.4 11/19/2005 03:30:00 6.7 0.7 8.4 4.6 6.7 0.7 8.4 4.6 6.6 0.8 8.4 4.6 202 5 197 165 0.5 0 0.7 0.4 11/19/2005 03:40:00 6.3 0.7 8 4.2 6.3 0.7 8.4 4.2 6.1 0.8 8 4.2 203 6 200 165 0.5 0 0.7 0.2 11/19/2005 03:50:00 6.5 0.8 8.4 4.6 6.6 0.8 8.8 4.6 6.1 0.9 8.4 4.2 211 6 217 165 0.5 0 0.7 0.2 11/19/2005 04:00:00 6.2 0.7 8.8 3.8 6.3 0.8 8.8 3.8 5.9 0.9 8.8 3.4 211 8 222 165 0.5 0 0.7 0.4 11/19/2005 04:10:00 7.4 1 9.9 4.9 7.5 1 9.9 4.9 7.1 0.9 9.5 4.9 219 6 219 165 0.7 0 0.9 0.4 11/19/2005 04:20:00 6.5 1 8.8 3.8 6.6 1 8.8 3.8 6.1 0.9 8.4 3.8 221 9 231 165 0.5 0 0.7 0.4 11/19/2005 04:30:00 6.9 1 9.5 4.2 7 1.1 9.5 4.2 6.6 1 9.9 4.2 220 7 219 165 0.5 0 0.7 0.2 11/19/2005 04:40:00 4.6 1.5 8.4 1.9 4.9 1.4 8.8 2.3 4.5 1.4 8.4 1.5 244 18 217 165 0.3 0.1 0.7 0.2 11/19/2005 04:50:00 5.3 1.3 8.4 1.9 5.4 1.3 8.4 2.6 5.1 1.2 8 2.3 237 12 233 165 0.2 0 0.4 0.2 11/19/2005 05:00:00 4.6 1.6 8.4 1.5 4.6 1.6 8.4 1.5 4.3 1.5 8.8 1.9 233 12 243 165 0.2 0 0.4 -0.1 11/19/2005 05:10:00 4.4 1.3 7.6 0.7 4.6 1.2 8 1.5 4.1 1.1 7.2 1.1 237 15 216 165 0 0 0.2 -0.1 11/19/2005 05:20:00 5.2 1.2 8 1.9 5.2 1.1 7.6 2.3 4.7 1.1 7.2 1.9 238 11 247 165 -0.1 0 -0.1 -0.3 11/19/2005 05:30:00 4.4 1.1 7.2 1.5 4.4 0.9 7.2 2.3 3.9 0.9 6.5 1.9 241 14 249 165 -0.1 0 0.2 -0.3 11/19/2005 05:40:00 4.6 1.4 7.2 1.1 4.7 1.3 7.2 1.5 4.1 1.2 6.8 1.5 244 16 245 165 -0.2 0 -0.1 -0.3 11/19/2005 05:50:00 3.7 0.7 5.7 1.9 4.2 0.6 5.7 1.9 4.1 0.6 5.3 1.9 264 9 275 165 -0.3 0 -0.1 -0.5 11/19/2005 06:00:00 3.9 0.8 6.5 1.9 4.5 0.7 6.5 2.6 4.3 0.6 6.5 3 262 8 261 165 -0.3 0 -0.3 -0.5 11/19/2005 06:10:00 4 0.8 6.8 2.3 4.8 0.8 6.8 3 4.4 0.7 6.5 3 257 8 256 165 -0.5 0 -0.3 -0.8 11/19/2005 06:20:00 3.5 0.8 5.7 1.5 4 0.7 5.7 2.3 3.6 0.7 5.3 1.9 267 9 273 165 -0.8 0.1 -0.5 -0.8 11/19/2005 06:30:00 3.2 0.8 4.9 1.5 3.6 0.8 5.7 1.5 3.3 0.9 5.3 1.5 259 12 285 165 -0.8 0 -0.5 -1 11/19/2005 06:40:00 2.9 0.6 4.6 1.1 3 0.6 4.6 1.5 2.9 0.5 4.6 1.5 246 8 246 165 -0.8 0 -0.8 -1 11/19/2005 06:50:00 3.3 0.5 4.6 1.9 3.2 0.5 4.6 1.9 3.2 0.5 4.6 1.9 240 11 249 165 -0.9 0 -0.8 -1.2 11/19/2005 07:00:00 2.9 0.5 4.6 1.9 3 0.6 4.6 0.7 3 0.6 4.2 1.1 262 15 249 165 -0.9 0 -0.8 -1 11/19/2005 07:10:00 2.7 0.6 4.6 1.1 2.8 0.5 4.2 1.5 2.8 0.6 4.2 1.5 268 11 287 165 -0.9 0 -0.8 -1.2 11/19/2005 07:20:00 3.4 0.7 5.7 1.5 3.5 0.7 5.7 1.9 3.3 0.6 5.3 1.9 274 10 294 165 -1.1 0 -1 -1.2 11/19/2005 07:30:00 4.2 0.9 5.7 1.5 4.5 0.8 6.5 1.9 4.2 0.8 6.1 1.9 275 10 274 165 -1.3 0 -1.2 -1.4 11/19/2005 07:40:00 3.1 0.7 4.9 1.5 3.3 0.6 4.9 1.9 2.7 0.7 4.6 1.5 278 9 285 165 -1.3 0 -1.2 -1.4 11/19/2005 07:50:00 2.2 0.7 3.8 0.4 2.4 0.8 3.8 0.4 2.2 0.7 3.8 0.4 260 10 263 165 -1.2 0 -1.2 -1.4 11/19/2005 08:00:00 2.9 0.6 4.6 0.7 3 0.6 4.6 1.5 2.7 0.6 4.2 1.5 270 10 281 165 -1.2 0 -1.2 -1.2 11/19/2005 08:10:00 3.9 0.6 5.3 2.3 4.1 0.7 6.1 2.6 3.7 0.7 5.7 1.5 273 8 263 165 -1.3 0 -1.2 -1.4 11/19/2005 08:20:00 2.5 0.8 4.2 0.7 2.7 0.8 4.6 1.1 2.5 0.5 3.8 1.1 262 11 266 165 -1.4 0 -1.2 -1.4 11/19/2005 08:30:00 2.2 0.5 3.4 0.7 2.2 0.5 3.4 1.1 2 0.5 3.4 0.4 263 13 246 165 -1.4 0 -1.2 -1.7 11/19/2005 08:40:00 2.1 0.7 3.4 0.4 2 0.8 3.4 0.4 1.8 0.8 3.4 0.4 263 15 238 165 -1.4 0 -1.2 -1.4 11/19/2005 08:50:00 1.6 0.8 3.8 0.4 1.2 0.8 3.4 0.4 1.1 0.8 3.4 0.4 233 21 206 165 -1.4 0 -1.2 -1.4 11/19/2005 09:00:00 1 0.7 3 0.4 0.8 0.6 2.6 0.4 0.8 0.6 2.6 0.4 256 27 231 165 -1.5 0 -1.4 -1.7 11/19/2005 09:10:00 1.7 0.9 4.2 0.4 1.6 1 4.2 0.4 1.4 0.9 3.8 0.4 263 19 251 165 -1.4 0 -1.2 -1.4 11/19/2005 09:20:00 3.3 0.5 4.6 1.9 3.7 0.5 4.9 2.3 3.5 0.4 4.6 2.6 265 6 264 165 -1.3 0 -1.2 -1.4 11/19/2005 09:30:00 3.5 0.6 4.9 2.3 3.5 0.6 4.9 2.3 3.1 0.7 4.6 1.1 284 9 286 165 -1.4 0 -1.2 -1.7 11/19/2005 09:40:00 3.7 0.5 4.9 2.6 3.7 0.5 4.9 2.3 3.1 0.6 4.6 1.9 290 5 292 165 -1.6 0 -1.4 -1.9 11/19/2005 09:50:00 3.3 0.4 4.2 2.3 3.3 0.4 4.2 1.9 2.6 0.6 4.2 1.5 294 7 289 165 -1.6 0 -1.4 -1.9 11/19/2005 10:00:00 4.2 0.7 6.1 2.6 4.2 0.7 6.1 2.6 3.3 0.7 5.3 1.5 294 7 285 165 -1.5 0 -1.4 -1.7 11/19/2005 10:10:00 4.3 0.6 6.1 2.3 4.3 0.6 6.1 2.3 3.5 0.6 5.7 1.9 290 6 295 165 -1.4 0 -1.4 -1.7 11/19/2005 10:20:00 5 0.6 6.1 3.4 5.1 0.6 6.1 3.4 3.9 0.6 5.7 2.6 296 6 292 165 -1.5 0 -1.4 -1.7 11/19/2005 10:30:00 5 0.5 6.1 3.8 5.1 0.6 6.1 3.4 4.1 0.8 6.1 2.3 292 6 288 165 -1.5 0 -1.4 -1.7 11/19/2005 10:40:00 5.3 0.7 6.8 3.4 5.3 0.7 6.8 3.4 4.2 0.8 6.5 2.3 292 6 281 165 -1.6 0 -1.4 -1.9 11/19/2005 10:50:00 5.9 0.5 6.8 4.2 6 0.5 6.8 4.2 4.7 0.7 6.5 3 291 5 290 165 -1.6 0 -1.4 -1.9 11/19/2005 11:00:00 5.4 0.6 6.5 3.8 5.5 0.6 6.5 3.8 4.6 0.9 6.8 2.6 289 6 297 165 -1.4 0 -1.2 -1.7 11/19/2005 11:10:00 5.7 0.7 7.2 4.6 5.8 0.7 7.6 4.6 5 1 7.2 2.6 287 7 286 165 -1.4 0 -1.2 -1.4 11/19/2005 11:20:00 5.4 0.6 7.2 3.4 5.5 0.7 7.2 3.4 5 0.9 6.8 2.3 283 6 278 165 -1.4 0 -1.2 -1.9 11/19/2005 11:30:00 5.4 0.7 7.2 3.4 5.4 0.7 7.2 3.8 5 0.8 7.6 2.3 283 7 290 165 -1.2 0 -1 -1.4 11/19/2005 11:40:00 5.4 0.7 7.2 3.4 5.5 0.7 7.2 3.8 5.1 1 7.2 2.6 283 6 284 165 -1.2 0 -1 -1.4 11/19/2005 11:50:00 4.9 0.6 6.8 3 5 0.7 6.8 3 4.5 0.9 6.8 2.3 282 7 277 165 -1.3 0 -1.2 -1.4 11/19/2005 12:00:00 5 0.7 6.8 3 5.5 0.7 7.2 3.4 5.1 0.8 6.8 3 272 8 265 165 -1.2 0 -1 -1.4 11/19/2005 12:10:00 4.7 1.3 7.2 2.3 5.4 1.2 7.6 3 5.1 1.2 7.6 2.6 265 9 271 165 -1 0.1 -0.5 -1.4 11/19/2005 12:20:00 4 1 6.1 1.9 4.5 1 6.5 2.6 4.3 1 6.8 2.3 267 9 277 165 0.2 0.2 0.7 -0.5 11/19/2005 12:30:00 5 0.7 7.6 3 5.6 0.6 7.2 3.8 5.4 0.6 6.8 3.8 272 6 273 165 0.1 0 0.2 -0.3 11/19/2005 12:40:00 4.2 1.2 6.8 1.5 4.4 1.2 6.8 1.1 4.1 1.1 6.1 0.7 276 10 269 165 0.3 0 0.7 0.2 11/19/2005 12:50:00 4.4 1 7.2 1.5 4.7 1 6.8 2.3 4.5 0.9 6.5 2.3 264 15 248 165 0.3 0.1 0.7 -0.1 11/19/2005 13:00:00 4.1 0.9 6.5 1.5 4.5 0.8 6.5 2.3 4.2 0.8 6.5 1.9 265 15 229 165 0.5 0.2 0.9 -0.1 11/19/2005 13:10:00 4.7 1 6.8 2.3 4.9 1 6.8 2.6 4.7 1 6.8 2.6 274 10 278 165 -0.3 0.1 0.2 -0.5 11/19/2005 13:20:00 3.9 0.9 5.7 1.9 4.5 0.8 6.8 2.6 4.3 0.8 6.5 1.9 269 11 277 165 -0.1 0.2 0.2 -0.5 11/19/2005 13:30:00 5.1 0.7 6.8 2.6 5.6 0.6 6.8 3.4 5.5 0.7 7.6 3.8 272 7 282 165 -0.5 0 -0.3 -0.8 11/19/2005 13:40:00 5 0.7 6.8 3 5.6 0.6 6.8 3.8 5.3 0.6 6.8 3.8 272 6 270 165 -0.6 0 -0.3 -0.8 11/19/2005 13:50:00 4.6 0.9 6.8 2.6 5.8 0.8 7.6 3.8 5.6 0.8 7.6 3.4 264 6 264 165 -0.9 0.2 -0.3 -1.2 11/19/2005 14:00:00 4.4 0.9 6.5 2.6 4.9 0.7 6.5 3 4.7 0.8 6.8 3 252 12 241 165 -0.5 0.2 -0.3 -1.2 11/19/2005 14:10:00 3.8 0.8 6.5 1.9 4.4 0.8 7.2 2.3 4.1 0.8 6.1 2.3 272 9 267 165 -0.2 0.1 0.2 -0.5 11/19/2005 14:20:00 5.3 1.2 9.5 2.6 5.7 1.2 9.1 2.6 5.5 1.3 8.8 2.3 276 13 284 165 -0.9 0.3 -0.5 -1.4 11/19/2005 14:30:00 4.2 1 7.2 2.3 4.9 1 8.4 2.6 4.5 1 8.4 2.3 262 12 261 165 -1.4 0 -1.2 -1.9 11/19/2005 14:40:00 4.5 1.2 8.4 1.9 4.8 1.1 8 2.3 4.4 1.1 8 2.3 247 11 242 165 -1.7 0 -1.4 -2.1 11/19/2005 14:50:00 6.1 1.5 9.1 2.3 6.3 1.5 9.5 2.3 6.2 1.5 10.3 1.5 219 8 216 165 -1.4 0.1 -1.2 -1.7 11/19/2005 15:00:00 5.6 1.4 9.1 2.3 5.9 1.3 9.1 2.6 5.4 1.4 8.8 1.9 234 17 245 165 -1.2 0.2 -0.8 -1.4 11/19/2005 15:10:00 6.7 1.5 10.3 2.3 7 1.3 10.7 3 6.6 1.4 10.3 3 243 19 232 165 -1 0 -0.8 -1.2 11/19/2005 15:20:00 4.5 1.3 8 1.9 4.9 1.1 8 2.6 4.6 1.1 7.6 2.3 254 12 247 165 -0.9 0.1 -0.8 -1.2 11/19/2005 15:30:00 4.6 1.3 8.4 1.9 5 1.1 7.6 2.3 4.7 1.1 7.6 2.3 265 15 243 165 -1.3 0 -1.2 -1.4 11/19/2005 15:40:00 4.1 1.2 6.8 1.5 4.3 1.2 6.5 1.5 4 1.1 6.1 1.9 278 10 274 165 -1.6 0.3 -1.2 -1.9 11/19/2005 15:50:00 4 0.9 6.1 1.5 4.4 1 6.1 1.5 4.1 0.9 5.7 1.5 270 12 262 165 -2.2 0.2 -1.9 -2.6 11/19/2005 16:00:00 4.1 0.8 6.1 1.9 4.7 0.9 7.2 2.3 4.3 1 6.8 2.3 265 11 261 165 -2.6 0 -2.6 -2.8 11/19/2005 16:10:00 4.8 0.8 6.8 2.6 5.7 0.8 7.6 3.4 5.3 0.8 6.8 2.6 262 9 262 165 -2.6 0 -2.6 -2.8 11/19/2005 16:20:00 5.1 0.9 7.6 2.6 5.8 0.6 7.6 4.2 5.4 0.7 7.2 4.2 258 9 248 165 -2.7 0 -2.6 -2.8 11/19/2005 16:30:00 4.5 0.9 6.8 2.3 5.1 0.6 6.8 3 4.8 0.6 6.1 3 251 8 244 165 -2.8 0 -2.6 -2.8 11/19/2005 16:40:00 4.4 0.5 6.1 3 4.4 0.5 6.1 3 4.3 0.5 6.1 3 242 8 247 165 -2.7 0 -2.6 -3 11/19/2005 16:50:00 5.2 1.1 8 1.9 5.3 1 8 3 5 1 7.6 3 236 13 217 165 -2.7 0 -2.6 -2.8 11/19/2005 17:00:00 4.4 0.6 5.7 3 4.4 0.6 6.1 3 4.2 0.6 5.3 2.6 231 7 230 165 -3 0.1 -2.6 -3 11/19/2005 17:10:00 5.5 1.5 9.1 3 5.8 1.6 9.5 3 5.3 1.7 9.5 2.6 242 11 250 165 -2.9 0 -2.6 -3.3 11/19/2005 17:20:00 6 1.3 9.5 2.6 6.3 1.2 9.5 3 5.9 1.2 9.1 2.3 236 19 228 165 -2.6 0 -2.6 -2.8 11/19/2005 17:30:00 6.6 2.3 11.1 2.3 6.7 2.2 10.7 2.3 6.3 2.1 10.3 2.6 238 11 247 165 -2.7 0.1 -2.6 -3 11/19/2005 17:40:00 7.4 1.3 10.7 4.2 7.8 1.1 10.7 4.9 7.3 1 10.7 4.9 245 11 248 165 -2.5 0 -2.4 -2.6 11/19/2005 17:50:00 7 1.2 9.9 3.8 7.1 1.2 9.9 3.8 6.9 1.3 9.5 3.8 231 13 237 165 -2.5 0 -2.4 -2.8 11/19/2005 18:00:00 4.9 0.9 7.6 2.6 5 0.8 7.6 2.6 4.6 0.9 7.2 3 235 12 221 165 -2.6 0 -2.6 -2.8 11/19/2005 18:10:00 4.8 0.9 7.6 2.3 5.6 0.9 7.6 3.4 5.4 0.9 7.6 3.4 253 9 231 165 -2.7 0 -2.6 -3 11/19/2005 18:20:00 4.7 0.8 7.2 2.6 5.1 0.6 6.8 3.4 4.9 0.6 6.5 3.4 248 11 251 165 -2.8 0 -2.6 -2.8 11/19/2005 18:30:00 4.9 0.9 7.2 2.6 5.2 0.8 7.2 3.8 5.1 0.8 6.8 2.6 248 7 251 165 -2.6 0 -2.6 -2.8 11/19/2005 18:40:00 5.3 0.9 7.6 3.4 5.7 0.9 8 3.8 5.4 1 7.6 2.6 244 10 237 165 -2.5 0 -2.4 -2.6 11/19/2005 18:50:00 4.2 1 6.8 2.3 4.8 0.8 6.5 3.4 4.4 0.7 6.1 3 257 12 245 165 -2.8 0 -2.4 -3 11/19/2005 19:00:00 4 1.2 7.2 1.5 4.6 1 7.2 3 4.4 1 7.2 1.9 254 8 247 165 -2.8 0 -2.6 -3 11/19/2005 19:10:00 4.8 0.6 6.5 3 4.9 0.5 6.5 3.4 4.6 0.5 6.1 3.4 243 9 244 165 -2.7 0 -2.6 -2.8 11/19/2005 19:20:00 4.1 0.4 5.3 3 4.2 0.4 5.3 3 4 0.5 5.3 2.6 213 11 222 165 -3 0.1 -2.6 -3 11/19/2005 19:30:00 4.4 0.5 5.7 3 4.4 0.5 5.3 3 4.5 0.5 5.7 3 193 8 193 165 -2.8 0 -2.6 -3.3 11/19/2005 19:40:00 3.8 0.5 4.9 2.6 3.8 0.5 4.9 2.6 3.7 0.4 4.6 2.3 209 6 207 165 -2.9 0.1 -2.6 -3 11/19/2005 19:50:00 4 0.7 5.3 2.3 4 0.7 5.7 2.3 4 0.7 6.1 2.6 206 7 206 165 -2.9 0 -2.6 -3 11/19/2005 20:00:00 3.5 0.6 4.9 2.3 3.5 0.5 4.9 2.3 3.5 0.5 4.9 1.9 192 9 183 165 -3 0.1 -2.6 -3 11/19/2005 20:10:00 5 0.4 6.1 3.8 4.9 0.4 5.7 3.4 5.1 0.5 6.1 3.4 186 5 182 165 -3.1 0 -3 -3.3 11/19/2005 20:20:00 4.7 0.3 5.7 3.8 4.6 0.3 5.3 3.8 4.7 0.3 5.3 3.8 188 6 194 165 -3 0 -2.8 -3 11/19/2005 20:30:00 4.9 0.4 6.1 3.8 4.8 0.4 5.7 3.8 4.7 0.5 6.1 3.4 185 5 185 165 -3.1 0 -2.8 -3.3 11/19/2005 20:40:00 5.4 0.6 6.5 4.2 5.3 0.5 6.5 4.2 5.6 0.6 6.8 4.2 184 3 181 165 -3.1 0 -3 -3.3 11/19/2005 20:50:00 4.4 0.3 5.7 3.8 4.3 0.3 5.3 3.8 4.3 0.3 5.3 3.8 179 5 189 165 -3.3 0 -3 -3.5 11/19/2005 21:00:00 4.6 0.7 6.1 3.4 4.4 0.7 6.1 3.4 4.5 0.6 6.1 3.4 178 3 176 165 -3.5 0 -3.3 -3.5 11/19/2005 21:10:00 4.8 0.5 6.1 4.2 4.7 0.4 5.7 3.8 4.8 0.5 6.1 4.2 181 2 177 165 -3.4 0 -3.3 -3.5 11/19/2005 21:20:00 5 0.3 5.7 4.6 4.9 0.2 5.3 4.2 5 0.3 5.7 4.2 179 2 180 165 -3.3 0 -3.3 -3.5 11/19/2005 21:30:00 4.5 0.4 5.3 3.8 4.5 0.3 4.9 3.8 4.7 0.4 5.3 3.8 187 6 180 165 -3.3 0 -3.3 -3.5 11/19/2005 21:40:00 3.6 0.4 4.6 2.6 3.7 0.5 4.9 2.6 3.3 0.5 4.6 1.9 205 4 202 165 -3.5 0.1 -3.3 -3.5 11/19/2005 21:50:00 4.3 0.4 4.9 3 4.4 0.4 5.3 3 4.1 0.5 4.9 2.6 204 5 201 165 -3.6 0 -3.5 -3.7 11/19/2005 22:00:00 4.4 0.7 5.7 2.3 4.4 0.7 5.7 2.6 4.2 0.9 5.7 2.3 197 7 192 165 -3.4 0 -3.3 -3.5 11/19/2005 22:10:00 4.4 0.5 5.7 3.8 4.4 0.5 5.3 3.4 4.6 0.5 5.7 3.4 192 2 187 165 -3.1 0 -3 -3.3 11/19/2005 22:20:00 4.7 0.6 5.7 3.4 4.5 0.6 5.3 3.4 4.6 0.7 5.7 3 184 5 180 165 -3.1 0 -3 -3.3 11/19/2005 22:30:00 5.3 0.3 6.1 4.9 5.2 0.3 5.7 4.6 5.4 0.3 6.1 4.6 181 3 181 165 -3.1 0 -3 -3.5 11/19/2005 22:40:00 5.5 0.3 6.1 4.9 5.4 0.2 5.7 4.6 5.6 0.2 6.1 4.9 183 2 183 165 -3.1 0 -3 -3.3 11/19/2005 22:50:00 4.8 0.9 6.1 2.6 4.7 0.9 6.1 2.6 4.8 1 6.1 3 178 5 180 165 -3.3 0 -3 -3.5 11/19/2005 23:00:00 3.9 0.3 4.6 3 3.8 0.3 4.6 3 3.8 0.4 4.6 2.6 182 3 179 165 -3.4 0 -3.3 -3.5 11/19/2005 23:10:00 3.5 0.3 4.2 3 3.4 0.2 3.8 2.6 3.6 0.3 4.2 3 176 5 185 165 -3.1 0.1 -2.8 -3.5 11/19/2005 23:20:00 3.9 0.4 4.6 3 3.7 0.4 4.2 3 3.9 0.4 4.6 3 172 4 165 165 -3.1 0 -3 -3.3 11/19/2005 23:30:00 3.5 0.2 4.2 3 3.4 0.2 4.2 3 3.5 0.2 4.2 3 166 2 167 165 -3.2 0 -3 -3.3 11/19/2005 23:40:00 3.1 0.2 3.4 2.6 3 0.2 3.4 2.6 3.2 0.2 3.8 2.6 176 4 169 165 -3.3 0 -3 -3.3 11/19/2005 23:50:00 3.1 0.4 3.8 2.3 3 0.4 3.8 2.3 3 0.4 3.8 1.9 178 5 179 165 -3.2 0 -3 -3.5 11/20/2005 00:00:00 4.3 0.4 5.3 3.4 4.2 0.4 4.9 3 4.2 0.4 4.9 2.6 171 4 176 165 -3.1 0.1 -2.8 -3.3 11/20/2005 00:10:00 4.2 0.3 4.9 3.4 4 0.3 4.6 3.4 3.9 0.3 4.6 3.4 170 3 171 165 -3 0 -2.8 -3.3 11/20/2005 00:20:00 4.1 0.2 4.6 3.8 3.9 0.2 4.2 3.4 3.9 0.3 4.6 3.4 169 3 167 165 -2.8 0 -2.6 -3 11/20/2005 00:30:00 3.9 0.2 4.2 3.4 3.7 0.2 4.2 3.4 3.8 0.2 4.2 3 163 4 165 165 -2.6 0 -2.6 -2.8 11/20/2005 00:40:00 3.6 0.2 3.8 3 3.4 0.2 3.8 2.6 3.6 0.2 3.8 3 167 3 168 165 -2.4 0 -2.1 -2.8 11/20/2005 00:50:00 2.9 0.3 3.4 2.3 2.8 0.2 3.4 2.3 2.9 0.2 3.4 2.3 175 4 179 165 -2.2 0 -2.1 -2.6 11/20/2005 01:00:00 3.7 0.3 4.2 3 3.6 0.3 4.2 2.6 3.7 0.3 4.2 3 172 3 175 165 -2.1 0 -2.1 -2.4 11/20/2005 01:10:00 2.9 0.4 3.8 2.3 2.8 0.4 3.8 2.3 2.9 0.5 3.8 1.9 180 6 172 165 -2.2 0 -2.1 -2.4 11/20/2005 01:20:00 2.6 0.5 3.8 1.5 2.6 0.5 3.8 1.5 2.5 0.4 3.4 1.5 193 8 183 165 -2 0.1 -1.7 -2.1 11/20/2005 01:30:00 1.7 0.5 3.4 0.4 1.6 0.5 3 0.4 1.6 0.4 2.6 0.7 181 13 200 165 -2 0 -1.9 -2.1 11/20/2005 01:40:00 1.3 0.5 2.3 0.4 1.2 0.5 2.3 0.4 1.2 0.4 2.3 0.4 162 6 147 165 -2 0 -1.9 -2.1 11/20/2005 01:50:00 2.5 0.4 3.4 1.5 2.4 0.3 3.4 1.5 2.6 0.4 3.4 1.9 173 6 179 165 -1.7 0 -1.7 -1.9 11/20/2005 02:00:00 2.2 0.4 3 1.1 2 0.4 2.6 0.7 2.2 0.4 3 1.1 163 3 162 165 -2.3 0.3 -1.9 -2.8 11/20/2005 02:10:00 0.8 0.5 1.9 0.4 0.6 0.4 1.5 0.4 0.7 0.5 2.3 0.4 158 8 170 165 -3 0.1 -2.8 -3.3 11/20/2005 02:20:00 0.9 0.6 2.3 0.4 0.8 0.6 2.3 0.4 0.9 0.5 1.9 0.4 157 61 139 165 -3.2 0 -3 -3.3 11/20/2005 02:30:00 1.6 0.4 2.3 0.7 1.4 0.4 2.3 0.4 1.5 0.3 2.3 0.7 131 3 131 165 -2.8 0.1 -2.6 -3 11/20/2005 02:40:00 0.6 0.3 1.5 0.4 0.4 0.2 1.5 0.4 0.4 0.2 1.1 0.4 137 5 124 165 -2.8 0 -2.6 -3 11/20/2005 02:50:00 0.4 0.1 1.1 0.4 0.4 0 0.4 0.4 0.4 0 0.7 0.4 161 7 163 165 -3 0 -2.8 -3 11/20/2005 03:00:00 0.5 0.3 1.5 0.4 0.4 0.2 1.1 0.4 0.9 0.3 1.5 0.4 31 94 0 165 -2.9 0 -2.8 -3 11/20/2005 03:10:00 0.5 0.3 1.5 0.4 0.4 0.2 1.5 0.4 0.5 0.3 1.9 0.4 23 64 99 165 -2.8 0 -2.6 -2.8 11/20/2005 03:20:00 0.9 0.7 2.6 0.4 0.8 0.6 3 0.4 0.7 0.6 2.6 0.4 172 30 188 165 -2.5 0 -2.1 -2.6 11/20/2005 03:30:00 0.5 0.3 1.9 0.4 0.5 0.2 1.9 0.4 0.5 0.3 1.9 0.4 149 47 116 165 -2.1 0 -2.1 -2.1 11/20/2005 03:40:00 0.5 0.3 1.5 0.4 0.4 0.1 1.1 0.4 0.9 0.4 1.9 0.4 47 39 10 165 -2.2 0 -2.1 -2.4 11/20/2005 03:50:00 0.5 0.2 1.1 0.4 0.4 0.2 1.1 0.4 0.7 0.4 1.5 0.4 22 12 28 165 -2.1 0 -1.9 -2.1 11/20/2005 04:00:00 0.8 0.5 1.9 0.4 0.7 0.5 1.9 0.4 1.1 0.4 2.3 0.4 53 23 92 165 -2 0 -1.9 -2.1 11/20/2005 04:10:00 1.7 0.3 2.3 0.7 1.6 0.4 2.6 0.7 1.7 0.4 2.6 1.1 113 5 108 165 -1.8 0 -1.7 -1.9 11/20/2005 04:20:00 2.2 0.7 3.8 0.7 2.1 0.7 3.8 0.4 2 0.5 3.4 0.7 111 8 118 165 -1.6 0 -1.4 -1.9 11/20/2005 04:30:00 2.4 0.3 3 1.5 2.4 0.4 3.4 1.1 2.3 0.3 3 1.5 104 9 99 165 -1.5 0 -1.4 -1.7 11/20/2005 04:40:00 1.8 0.4 3 0.7 1.7 0.4 3 0.7 1.6 0.5 2.6 0.4 91 12 97 165 -1.6 0 -1.4 -1.9 11/20/2005 04:50:00 1.8 0.5 2.6 0.4 1.5 0.5 2.6 0.4 1.7 0.5 2.6 0.4 32 23 84 165 -1.8 0 -1.7 -1.9 11/20/2005 05:00:00 2.3 0.8 4.9 0.4 2.2 1 4.9 0.4 1.9 0.6 4.6 0.7 57 28 102 165 -1.8 0 -1.7 -1.9 11/20/2005 05:10:00 3.5 1 5.3 1.1 3.5 1.1 5.3 1.1 3 1 4.9 0.7 84 11 91 165 -1.4 0 -1.2 -1.7 11/20/2005 05:20:00 2.4 0.7 4.6 1.1 2.3 0.7 4.6 0.4 2.1 0.6 3.8 0.7 56 21 94 165 -1.5 0 -1.4 -1.7 11/20/2005 05:30:00 4 0.7 5.7 1.5 4.1 0.7 5.7 1.1 3.4 0.8 5.7 1.1 86 11 85 165 -1.4 0 -1.2 -1.7 11/20/2005 05:40:00 3 0.9 4.9 1.1 2.9 1 4.9 0.4 2.4 0.7 4.2 0.7 68 21 81 165 -1.3 0.1 -1.2 -1.4 11/20/2005 05:50:00 2.8 0.6 4.6 1.1 2.7 0.6 4.6 1.1 2.6 0.5 3.8 0.7 51 19 62 165 -1.2 0 -1 -1.4 11/20/2005 06:00:00 4.5 1 6.8 2.3 4.5 1 6.8 1.9 4.1 1 6.5 1.9 95 15 106 165 -0.6 0.3 -0.3 -1.4 11/20/2005 06:10:00 3.3 0.9 5.7 1.1 3.2 1 5.7 0.7 2.8 0.9 5.3 0.7 119 19 110 165 -0.8 0.3 -0.1 -1.2 11/20/2005 06:20:00 4.9 0.8 6.8 3 4.9 0.8 6.8 3 4.5 0.9 6.8 2.3 105 8 114 165 -0.9 0.2 -0.5 -1.4 11/20/2005 06:30:00 7.6 0.9 9.5 5.7 7.6 0.9 9.1 5.7 7.3 1 9.5 4.9 119 7 124 165 -0.6 0.1 -0.3 -0.8 11/20/2005 06:40:00 6.1 1.1 8.8 3 6.1 1.2 8.8 3 5.8 1.2 8.8 3 130 8 125 165 -0.5 0 -0.3 -0.8 11/20/2005 06:50:00 3.8 1 5.7 1.1 3.7 1.1 5.7 1.1 3.6 1 5.3 1.1 133 6 135 165 -0.8 0.1 -0.5 -0.8 11/20/2005 07:00:00 2.4 0.5 3.8 1.1 2.4 0.6 3.8 0.7 2 0.7 3 0.4 112 11 117 165 -0.9 0 -0.8 -1 11/20/2005 07:10:00 3.8 0.6 5.7 2.6 3.9 0.6 5.7 2.3 3.4 0.7 5.3 1.9 70 12 77 165 -0.6 0 -0.5 -1 11/20/2005 07:20:00 4.2 0.5 5.7 3 4.2 0.5 5.7 3 3.8 0.5 4.9 2.3 54 12 60 165 -0.6 0 -0.5 -0.8 11/20/2005 07:30:00 3.8 0.4 5.3 2.6 3.7 0.4 5.7 2.6 3.7 0.4 4.9 3 39 8 17 165 -0.8 0.1 -0.5 -1 11/20/2005 07:40:00 4 0.8 6.1 1.9 4 0.8 6.1 1.9 3.7 0.8 6.1 1.5 56 17 74 165 -0.9 0 -0.8 -0.8 11/20/2005 07:50:00 5.7 1.4 9.1 2.6 5.7 1.5 9.1 2.6 5.3 1.3 8.8 3 70 19 89 165 -0.6 0.2 -0.3 -1 11/20/2005 08:00:00 5.2 1.3 8.8 2.6 5.2 1.3 8.8 2.6 4.8 1.2 8.4 2.3 71 13 65 165 -0.3 0 -0.1 -0.8 11/20/2005 08:10:00 4.6 0.8 6.5 1.9 4.7 0.9 6.8 1.9 4.4 0.8 6.1 2.6 56 12 60 165 -0.6 0 -0.3 -0.8 11/20/2005 08:20:00 4.8 1 8 3 4.8 1 8.4 3 4.6 0.8 7.2 2.6 46 14 47 165 -0.4 0 -0.3 -0.8 11/20/2005 08:30:00 4.7 0.7 6.5 2.6 4.8 0.8 6.5 2.6 4.5 0.7 6.5 3 50 10 54 165 -0.3 0 -0.3 -0.8 11/20/2005 08:40:00 5.1 0.7 6.5 3.8 5.1 0.6 6.5 3.4 4.9 0.7 6.5 3 33 9 32 165 -0.3 0 -0.3 -0.5 11/20/2005 08:50:00 4.1 0.7 6.8 2.6 4.1 0.7 6.8 2.6 3.9 0.5 6.1 2.3 38 9 56 165 -0.3 0 -0.1 -0.5 11/20/2005 09:00:00 6.1 1 9.1 4.2 6.1 1 9.1 3.4 5.6 1 8.8 3.8 47 12 51 165 -0.2 0 -0.1 -0.5 11/20/2005 09:10:00 5.3 1 8.8 3 5.3 1 9.1 3 4.8 0.8 7.6 3 49 13 62 165 -0.2 0 -0.1 -0.5 11/20/2005 09:20:00 5.7 1 8 3.4 5.6 1.1 7.6 3 5.3 0.9 7.6 3 58 11 66 165 -0.1 0 0.2 -0.3 11/20/2005 09:30:00 5.6 0.8 8 3.4 5.5 0.9 8.4 3.4 5.1 0.8 7.6 3.4 42 12 57 165 0.1 0 0.2 -0.1 11/20/2005 09:40:00 6.3 1.2 9.5 3.8 6.2 1.3 9.5 3.4 5.9 1.1 9.5 3 44 10 52 165 0 0 0.2 -0.1 11/20/2005 09:50:00 6.4 1 9.1 4.2 6.3 1 9.1 3.8 6.2 1 9.1 3.8 39 9 46 165 0 0 0.2 -0.3 11/20/2005 10:00:00 7 1.1 10.7 4.2 7.1 1.2 10.3 3.8 6.7 1.1 9.5 3.8 49 12 32 165 0.1 0 0.2 -0.1 11/20/2005 10:10:00 8.7 1 11.8 5.7 8.7 1.1 11.5 5.7 8.3 1.1 11.5 4.9 41 9 40 165 0.1 0 0.2 -0.1 11/20/2005 10:20:00 8.9 1.2 11.5 5.3 8.9 1.2 11.8 4.9 8.4 1.3 11.1 4.2 34 8 34 165 0.2 0 0.2 -0.1 11/20/2005 10:30:00 9.2 1.2 11.8 6.1 9.1 1.2 11.8 5.7 8.8 1.2 11.5 5.7 35 7 32 165 0.2 0 0.4 -0.1 11/20/2005 10:40:00 10.4 1.1 13 6.8 10.3 1.1 12.6 6.8 10.1 1.3 13.3 6.8 37 8 42 165 0.3 0 0.7 0.2 11/20/2005 10:50:00 10.1 1.2 12.6 6.5 9.9 1.2 12.6 6.1 9.5 1.2 12.6 6.1 28 7 27 165 0.3 0 0.4 -0.1 11/20/2005 11:00:00 9.6 1.5 12.6 6.1 9.4 1.5 12.6 5.3 9.2 1.5 12.6 5.7 25 7 25 165 0.2 0 0.4 -0.1 11/20/2005 11:10:00 7.9 1.1 10.7 5.3 7.5 1.2 10.3 4.6 7.5 1 10.7 4.9 22 9 9 165 0.5 0 0.7 0.2 11/20/2005 11:20:00 8.4 1.3 11.5 5.3 7.9 1.4 11.1 4.6 8 1.3 11.8 5.3 21 9 12 165 0.7 0 0.9 0.4 11/20/2005 11:30:00 8.8 1.1 11.5 5.7 8.2 1.5 11.1 3.8 8.4 1.1 11.1 4.6 18 9 2 165 0.8 0 0.9 0.4 11/20/2005 11:40:00 8.2 1.6 12.2 5.3 7.7 2 12.2 3.4 7.8 1.5 11.5 4.9 20 11 41 165 0.8 0 0.9 0.9 11/20/2005 11:50:00 9.6 1.8 13.7 5.3 8.7 1.9 13.3 4.2 9.3 1.7 13.3 4.9 18 10 16 165 0.9 0 1.1 0.7 11/20/2005 12:00:00 9.2 1.1 12.6 6.8 7.6 1.5 11.1 4.2 8.9 1.3 12.2 6.1 11 6 9 165 0.8 0 0.9 0.9 11/20/2005 12:10:00 10.3 0.9 12.6 8 8.4 1.2 11.8 5.3 10.1 1 12.6 7.6 10 5 14 165 0.8 0 0.9 0.9 11/20/2005 12:20:00 9.9 1 12.6 7.2 8.5 1.5 11.8 4.2 9.8 1.1 12.6 6.8 16 4 16 165 0.8 0 0.9 0.7 11/20/2005 12:30:00 9.4 1 12.6 6.8 7.3 1.5 11.8 4.2 9.4 1.1 12.6 6.1 18 0 18 165 0.8 0 0.9 0.7 11/20/2005 12:40:00 9 1.2 11.8 6.5 6.9 1.7 12.2 3.8 9 1.3 12.6 6.1 18 0 18 165 0.8 0 0.9 0.7 11/20/2005 12:50:00 9.3 0.9 11.5 7.2 6.3 1.2 11.1 4.2 9.4 0.9 12.2 7.2 18 0 18 165 0.8 0 0.9 0.7 11/20/2005 13:00:00 9.4 1 12.2 6.5 7 1.5 10.7 3.8 9.7 1 12.6 6.8 18 0 18 165 0.8 0 1.1 0.9 11/20/2005 13:10:00 7.4 0.7 9.5 5.7 5.9 1.3 8.8 2.6 7.3 0.8 9.1 4.9 18 0 18 165 0.9 0 1.1 0.9 11/20/2005 13:20:00 6.7 0.8 8.8 4.9 4.8 1 7.6 2.6 6.6 0.8 8.8 4.6 18 0 18 165 1 0 1.1 0.7 11/20/2005 13:30:00 5.5 0.7 7.2 3 4.2 1.1 6.8 1.9 5.5 0.7 7.2 3.4 18 0 18 165 0.9 0 1.1 0.9 11/20/2005 13:40:00 4.7 0.9 7.2 3 4.6 1 7.6 1.9 4.5 0.9 7.2 2.6 18 0 18 165 0.9 0 1.1 0.9 11/20/2005 13:50:00 4.9 0.8 7.2 3 4.8 0.9 7.2 3 4.7 0.8 7.2 3 18 0 18 165 0.8 0 0.9 0.9 11/20/2005 14:00:00 4.2 0.5 5.7 2.6 4 0.5 5.3 2.6 4 0.5 5.7 3 18 0 18 165 0.8 0 0.9 0.7 11/20/2005 14:10:00 4.9 0.5 5.7 3.8 4.8 0.5 5.7 3.4 4.6 0.5 5.7 3.4 18 0 18 165 0.8 0 0.9 0.9 11/20/2005 14:20:00 5.8 0.6 7.6 4.6 5.8 0.6 7.6 4.6 5.5 0.6 7.2 3.8 18 0 18 165 0.9 0 0.9 0.7 11/20/2005 14:30:00 6.2 0.7 8 4.2 6.2 0.7 8.4 4.2 6 0.7 8 3.4 18 0 18 165 0.8 0 0.9 0.7 11/20/2005 14:40:00 6.1 0.6 8 4.2 6.1 0.6 8 4.2 5.8 0.6 7.2 4.2 18 0 18 165 0.8 0 0.9 0.7 11/20/2005 14:50:00 6.6 0.6 8.4 5.3 6.6 0.6 8.4 4.9 6.3 0.6 8.4 4.9 18 0 18 165 0.9 0 1.1 0.7 11/20/2005 15:00:00 6.6 0.7 8.4 4.9 6.6 0.7 8.4 4.9 6.2 0.7 8 4.2 18 0 18 165 0.9 0 1.1 0.7 11/20/2005 15:10:00 6.3 0.7 8.4 4.9 6.3 0.7 8.8 4.9 6 0.6 8.4 4.2 18 0 18 165 1.1 0 1.4 0.9 11/20/2005 15:20:00 6 0.8 8.4 3.8 6 0.8 8 3.4 5.8 0.7 8.4 4.2 18 0 18 165 0.9 0 1.1 0.9 11/20/2005 15:30:00 6.4 0.8 8.4 4.6 6.3 1 8.8 3.8 6.2 0.8 8.4 4.6 18 0 18 165 0.8 0 0.9 0.7 11/20/2005 15:40:00 6.1 0.9 8.4 3 6.1 1 8.4 3 5.9 0.9 8 3 18 0 18 165 0.8 0 0.9 0.9 11/20/2005 15:50:00 6.6 0.6 8.8 4.6 6.6 0.7 8.4 3.8 6.6 0.6 8.4 4.9 18 0 18 165 0.7 0 0.9 0.4 11/20/2005 16:00:00 6.9 1.4 10.3 3.8 6.9 1.4 10.3 3.8 6 0.9 8.4 3.8 18 0 18 165 0.4 0 0.7 0.2 11/20/2005 16:10:00 5.5 1.1 8 2.6 5.5 1.2 8 2.3 4.6 1.1 7.6 1.9 18 0 18 165 0.2 0 0.4 0.2 11/20/2005 16:20:00 6.4 1.3 9.5 2.6 6.3 1.3 9.5 2.6 5.2 1.3 8.8 1.9 18 0 18 165 0.2 0 0.2 -0.1 11/20/2005 16:30:00 8.4 1.5 11.1 4.6 8.5 1.5 11.1 4.2 7.7 2 11.5 3 18 0 18 165 0.1 0 0.2 -0.1 11/20/2005 16:40:00 10 1 12.6 7.6 10.1 1 12.6 7.2 8.6 1.5 13 5.3 18 0 18 165 0.1 0 0.2 -0.1 11/20/2005 16:50:00 9.8 1 11.8 6.8 9.8 1 12.2 6.8 7.3 1.2 10.7 4.9 18 0 18 165 0.2 0 0.2 -0.1 11/20/2005 17:00:00 9.5 0.8 11.8 7.2 9.5 0.8 12.6 7.2 7.2 1.3 12.2 4.9 18 0 18 165 0.2 0 0.4 0.2 11/20/2005 17:10:00 9.3 0.8 11.1 6.5 9.4 0.8 11.1 6.8 7.9 1.2 11.1 4.2 18 0 18 165 0.3 0 0.4 0.2 11/20/2005 17:20:00 9.1 1 11.5 6.1 9.1 1 11.5 6.1 6.7 1.1 9.5 4.2 18 0 18 165 0.4 0 0.7 0.2 11/20/2005 17:30:00 9 1 11.5 6.5 9 0.9 11.1 6.5 6.6 1.1 10.7 4.6 18 0 18 165 0.5 0 0.7 0.2 11/20/2005 17:40:00 9.2 0.7 10.7 6.8 9.1 0.7 10.7 6.8 6.2 0.7 8.4 4.6 18 0 18 165 0.5 0 0.7 0.2 11/20/2005 17:50:00 10 0.5 11.1 8 9.9 0.4 11.1 8 6.8 0.6 9.1 5.3 18 0 18 165 0.5 0 0.7 0.2 11/20/2005 18:00:00 9.6 0.7 11.5 7.2 9.5 0.6 11.1 7.2 6.6 0.6 8.4 4.9 18 0 18 165 0.5 0 0.7 0.2 11/20/2005 18:10:00 9.4 0.7 11.1 7.2 9.3 0.6 11.1 7.2 6.5 0.8 9.9 4.9 18 0 18 165 0.5 0 0.7 0.2 11/20/2005 18:20:00 8.4 0.6 9.9 6.8 8.3 0.6 9.5 6.8 6 0.6 8.4 4.6 18 0 18 165 0.5 0 0.7 0.2 11/20/2005 18:30:00 7.5 0.6 8.8 5.7 7.5 0.6 8.8 6.1 5.6 0.7 8 3.8 18 0 18 165 0.5 0 0.7 0.2 11/20/2005 18:40:00 7.4 0.9 9.5 5.3 7.3 0.8 9.1 5.3 5.7 0.8 8.8 3.4 18 0 18 165 0.5 0 0.7 0.4 11/20/2005 18:50:00 7.8 0.6 9.1 6.1 7.8 0.6 9.1 6.1 5.8 0.7 7.6 3.8 18 0 18 165 0.4 0 0.7 0.2 11/20/2005 19:00:00 8.5 0.5 9.9 6.8 8.5 0.5 9.9 7.2 6.5 0.8 9.5 4.9 18 0 18 165 0.3 0 0.7 0.2 11/20/2005 19:10:00 9.2 0.9 11.1 6.8 9.1 0.8 10.7 6.8 6.4 0.8 8.8 4.6 18 0 18 165 0.2 0 0.2 -0.1 11/20/2005 19:20:00 9.2 0.8 11.5 7.2 9.1 0.7 11.1 7.2 6.5 0.8 8.8 4.9 18 0 18 165 0 0 0.2 -0.1 11/20/2005 19:30:00 9.6 0.9 11.5 7.6 9.5 0.8 11.1 7.6 7 1 10.3 4.6 18 0 18 165 0 0 0.2 -0.3 11/20/2005 19:40:00 9.8 0.8 11.8 6.8 9.7 0.8 11.1 6.8 8.1 1.2 10.7 5.3 18 0 18 165 -0.1 0 0.2 -0.3 11/20/2005 19:50:00 9.8 0.9 11.8 6.8 9.7 0.9 11.8 6.8 8.3 1.2 10.7 5.3 18 0 18 165 0 0 0.2 -0.3 11/20/2005 20:00:00 8.2 1 10.7 5.7 8.2 1 10.7 5.7 7.5 1.2 9.9 4.2 18 0 18 165 0.1 0 0.2 -0.1 11/20/2005 20:10:00 7 0.8 9.5 4.9 7 0.8 9.1 5.3 6 0.8 7.6 4.2 18 0 18 165 0.1 0 0.2 -0.1 11/20/2005 20:20:00 5.3 0.8 7.6 3.4 5.3 0.8 7.6 3 5.1 0.7 7.2 3.4 18 0 18 165 0.1 0 0.2 -0.1 11/20/2005 20:30:00 5.1 0.6 6.5 3.8 5.1 0.6 6.5 3.8 4.8 0.8 6.8 2.6 18 0 18 165 0.1 0 0.2 -0.3 11/20/2005 20:40:00 4.3 0.4 5.7 3 4.2 0.4 5.7 3 4.2 0.5 5.3 3 18 0 18 165 0 0 0.2 -0.3 11/20/2005 20:50:00 4.4 0.9 7.2 2.3 4.4 0.9 7.2 1.9 3.9 0.6 5.7 2.6 18 0 18 165 0 0 0.2 -0.3 11/20/2005 21:00:00 7.2 0.7 9.5 5.3 7.1 0.7 9.1 4.9 5.6 0.8 8.4 3.4 18 0 18 165 -0.1 0 -0.1 -0.3 11/20/2005 21:10:00 7.3 0.8 9.5 4.6 7.2 0.8 9.5 4.2 6 0.8 8 4.2 18 0 18 165 -0.1 0 0.2 -0.3 11/20/2005 21:20:00 7 0.6 9.1 5.3 7 0.6 9.1 5.3 5.3 0.7 8 3.8 18 0 18 165 -0.1 0 0.2 -0.3 11/20/2005 21:30:00 7.8 0.7 9.5 5.7 7.8 0.7 9.5 5.7 6.1 0.8 8 4.6 18 0 18 165 -0.1 0 -0.1 -0.3 11/20/2005 21:40:00 6.8 1 9.1 4.2 6.8 0.9 9.1 4.6 6.1 0.8 8 3.8 18 0 18 165 -0.2 0 -0.1 -0.3 11/20/2005 21:50:00 5.4 1 8 3 5.4 1 8 3 4.9 0.9 7.6 2.6 18 0 18 165 -0.2 0 -0.1 -0.3 11/20/2005 22:00:00 7 1.5 9.9 3.4 6.9 1.4 9.9 3.8 6.7 1.5 10.3 3 18 0 18 165 -0.1 0 0.2 -0.5 11/20/2005 22:10:00 7.5 1.3 10.7 4.6 7.3 1.5 10.7 3.8 6.8 1.5 10.3 3.4 18 0 18 165 -0.2 0.1 -0.1 -0.3 11/20/2005 22:20:00 5.3 1.3 8 1.5 5.2 1.3 8 1.9 4.8 1.2 7.6 1.5 18 0 18 165 -0.3 0 -0.3 -0.5 11/20/2005 22:30:00 5.1 1 8.4 3.4 4.9 1 8.4 2.6 4.7 0.8 7.6 2.6 18 0 18 165 -0.3 0 -0.3 -0.5 11/20/2005 22:40:00 6.8 1.2 10.3 4.6 6.4 1.5 10.3 3 6.3 1.3 10.3 3.8 18 0 18 165 -0.3 0 -0.3 -0.5 11/20/2005 22:50:00 7.5 1.4 10.7 3.4 7.1 1.5 11.1 3 6.9 1.3 9.9 3.4 18 0 18 165 -0.3 0 -0.3 -0.8 11/20/2005 23:00:00 8.6 1.3 11.8 5.3 8.3 1.6 11.8 3.4 7.9 1.5 11.8 4.6 18 0 18 165 -0.4 0 -0.3 -0.5 11/20/2005 23:10:00 7.1 1.1 10.7 3.8 7 1.2 11.5 3 6.5 1.1 9.5 3.8 18 0 18 165 -0.5 0 -0.5 -0.8 11/20/2005 23:20:00 8.5 1.3 11.5 5.3 8.6 1.3 11.8 5.3 7.9 1.2 10.7 4.6 18 0 18 165 -0.6 0 -0.5 -0.8 11/20/2005 23:30:00 9.4 1.2 12.6 6.1 9.4 1.4 12.2 6.1 8.8 1.3 11.8 5.3 18 0 18 165 -0.6 0 -0.5 -0.8 11/20/2005 23:40:00 8.5 1 11.5 6.5 8.5 1 11.8 6.5 7.9 1 11.1 5.3 18 0 18 165 -0.7 0 -0.5 -1 11/20/2005 23:50:00 8.3 1.1 11.1 4.9 8 1.5 11.1 3 7.9 1.2 12.2 4.9 18 0 18 165 -0.6 0 -0.5 -0.8 11/21/2005 00:00:00 11.4 1.3 14.9 8 10.9 1.9 14.9 5.7 10.8 1.3 14.1 6.5 18 0 18 165 -0.8 0 -0.5 -1 11/21/2005 00:10:00 11.2 1.3 14.5 7.6 11 1.7 14.9 5.3 10.4 1.3 13.7 6.8 18 0 18 165 -1 0 -0.8 -1.2 11/21/2005 00:20:00 11 1.2 14.1 7.6 11.1 1.2 14.5 7.2 10 1.4 13 6.1 18 0 18 165 -1.2 0 -1 -1.4 11/21/2005 00:30:00 9.2 1 11.5 6.5 9.3 1.1 11.8 6.5 8.2 1 10.7 4.6 18 0 18 165 -1.2 0 -1.2 -1.4 11/21/2005 00:40:00 8.8 1.1 12.2 6.1 8.7 1.1 12.2 5.7 8.1 1.2 11.8 4.9 18 0 18 165 -1.2 0 -1.2 -1.4 11/21/2005 00:50:00 9.1 1.2 12.6 6.5 9 1.3 13.3 6.1 8.5 1.3 12.2 5.7 18 0 18 165 -1.2 0 -1.2 -1.4 11/21/2005 01:00:00 8.8 1.4 11.8 5.3 8.8 1.3 11.8 5.3 8.4 1.3 11.5 5.3 18 0 18 165 -1.3 0 -1.2 -1.4 11/21/2005 01:10:00 7.4 1.1 11.1 5.3 7.2 1.3 11.1 3.4 7.2 1.1 12.2 4.6 18 0 18 165 -1.3 0 -1.2 -1.4 11/21/2005 01:20:00 6.8 1.1 9.5 4.2 6.3 1.3 9.5 3 6.3 1.1 9.1 3.4 18 0 18 165 -1.4 0 -1.2 -1.4 11/21/2005 01:30:00 6.9 1.3 10.3 3.8 6.8 1.5 11.1 3.8 6.4 1.4 9.9 3.4 18 0 18 165 -1.5 0 -1.4 -1.7 11/21/2005 01:40:00 6.6 1.5 10.7 3.4 6.2 1.6 10.3 3 6.2 1.5 10.3 3 18 0 18 165 -1.4 0 -1.4 -1.7 11/21/2005 01:50:00 7.1 1.2 10.3 4.2 6.5 1.6 10.3 3 6.5 1.3 10.7 2.6 18 0 18 165 -1.4 0 -1.4 -1.7 11/21/2005 02:00:00 5.1 1.1 9.9 3 4.6 1.3 9.9 1.5 4.5 1.1 9.5 1.9 18 0 18 165 -1.5 0 -1.4 -1.7 11/21/2005 02:10:00 4.8 0.9 7.6 3 4.1 1.2 7.6 1.5 4.3 0.8 7.2 3 18 0 18 165 -1.6 0 -1.4 -1.9 11/21/2005 02:20:00 5.9 0.9 8.4 3.8 5.5 1.2 8.4 3 5.4 0.8 7.6 3 18 0 18 165 -1.6 0 -1.4 -1.9 11/21/2005 02:30:00 6.5 1.2 9.1 4.6 6 1.5 9.5 2.6 6.1 1.2 9.1 4.2 18 0 18 165 -1.5 0 -1.4 -1.7 11/21/2005 02:40:00 6.9 1.3 9.9 3.8 6.8 1.3 10.3 3.4 6.1 1.3 9.5 3 18 0 18 165 -1.4 0 -1.2 -1.7 11/21/2005 02:50:00 7.8 1.6 11.1 4.2 7.4 1.9 11.1 3.8 7.2 1.7 11.1 3 18 0 18 165 -1.3 0 -1.2 -1.4 11/21/2005 03:00:00 8.3 1.5 12.6 4.9 8.2 1.5 12.2 4.6 7.6 1.4 11.1 3.8 18 0 18 165 -1.3 0 -1.2 -1.4 11/21/2005 03:10:00 9.8 1.1 13 6.1 9.8 1.2 13 5.7 9.1 1.2 11.8 4.9 18 0 18 165 -1.4 0 -1.2 -1.4 11/21/2005 03:20:00 8.6 1.3 11.8 5.7 8.6 1.3 11.8 5.3 8.1 1.4 11.1 4.9 18 0 18 165 -1.4 0 -1.2 -1.4 11/21/2005 03:30:00 7.5 1 9.5 4.6 7.4 1.1 9.9 4.2 6.9 1.1 9.5 3.8 18 0 18 165 -1.4 0 -1.2 -1.4 11/21/2005 03:40:00 6.6 1.1 9.5 3 6.6 1.1 9.5 3.8 6 1.2 8.8 3 18 0 18 165 -1.4 0 -1.2 -1.4 11/21/2005 03:50:00 6.1 1.6 9.5 3.4 6 1.6 9.5 3 5.7 1.4 9.1 3 18 0 18 165 -1.4 0 -1.2 -1.7 11/21/2005 04:00:00 8.1 1.1 11.1 5.7 8.1 1.2 11.5 5.3 7.5 1 10.7 4.9 18 0 18 165 -1.3 0 -1.2 -1.4 11/21/2005 04:10:00 8.8 1.1 12.2 6.1 8.6 1.3 12.2 4.6 8.3 1.1 12.2 5.3 18 0 18 165 -1.4 0 -1.2 -1.7 11/21/2005 04:20:00 7.8 0.9 10.3 4.9 7.7 1.1 10.3 4.2 7.1 0.9 9.5 4.2 18 0 18 165 -1.4 0 -1.2 -1.4 11/21/2005 04:30:00 8.3 0.8 10.3 6.1 8.1 1.2 10.7 4.6 7.6 0.9 9.9 5.3 18 0 18 165 -1.4 0 -1.4 -1.4 11/21/2005 04:40:00 7.5 1.1 10.7 5.3 7.6 1.1 10.7 4.9 6.6 1.1 9.5 3.8 18 0 18 165 -1.4 0 -1.4 -1.4 11/21/2005 04:50:00 7.7 0.9 10.7 5.7 7.7 1 11.1 4.6 6.7 1 9.9 3.8 18 0 18 165 -1.4 0 -1.4 -1.4 11/21/2005 05:00:00 7.8 0.9 10.3 5.3 7.7 1 10.7 4.9 7 1 9.5 4.6 18 0 18 165 -1.5 0 -1.4 -1.9 11/21/2005 05:10:00 7.4 1.2 10.7 4.9 7.4 1.3 10.7 3.8 6.6 1.3 9.5 3.4 18 0 18 165 -1.4 0 -1.4 -1.7 11/21/2005 05:20:00 7.5 0.8 9.5 4.2 7.4 1 10.3 4.2 7 0.9 10.7 4.6 18 0 18 165 -1.4 0 -1.2 -1.4 11/21/2005 05:30:00 7.7 1 10.7 4.9 7.6 1.1 11.5 4.9 7 1.1 9.9 3.8 18 0 18 165 -1.4 0 -1.2 -1.7 11/21/2005 05:40:00 8.2 1.1 11.1 5.3 8.1 1.4 11.8 4.2 7.8 1.1 10.7 4.9 18 0 18 165 -1.4 0 -1.2 -1.7 11/21/2005 05:50:00 9 1 11.8 5.7 9.1 0.9 11.5 5.7 8.6 1 10.7 6.1 18 0 18 165 -1.4 0 -1.2 -1.4 11/21/2005 06:00:00 8.5 1.1 11.5 6.1 8.5 1.3 11.5 5.3 8 1 10.3 6.1 18 0 18 165 -1.5 0 -1.4 -1.7 11/21/2005 06:10:00 8.7 1.3 11.8 4.9 8.7 1.4 11.5 4.6 8.5 1.3 12.2 4.6 18 0 18 165 -1.6 0 -1.4 -1.9 11/21/2005 06:20:00 7.7 1.3 10.7 4.9 7.1 1.5 9.9 3.8 7.4 1.4 9.9 3.8 18 0 18 165 -1.6 0 -1.4 -1.7 11/21/2005 06:30:00 7.5 0.9 10.7 5.3 7.2 1.1 10.7 3.8 7.2 1 9.5 4.9 18 0 18 165 -1.6 0 -1.4 -1.9 11/21/2005 06:40:00 5.7 1.2 9.1 4.2 5.7 1.1 9.1 3.8 5.6 1.1 8.8 3.4 18 0 18 165 -1.5 0 -1.4 -1.9 11/21/2005 06:50:00 5.6 0.7 7.2 3.4 5.3 0.9 7.6 2.6 5.4 0.7 7.6 3.4 18 0 18 165 -1.5 0 -1.2 -1.7 11/21/2005 07:00:00 6.6 0.7 8.4 4.6 6.6 0.8 8.4 4.6 6.5 0.7 8.4 4.6 18 0 18 165 -1.6 0 -1.4 -1.9 11/21/2005 07:10:00 6.5 0.7 8.4 4.9 6.5 0.7 8.4 4.6 6.4 0.7 8 4.6 18 0 18 165 -1.6 0 -1.4 -1.7 11/21/2005 07:20:00 6.4 0.6 8.4 4.6 6.3 0.7 8.8 4.6 6.2 0.6 8 4.6 18 0 18 165 -1.7 0 -1.4 -1.9 11/21/2005 07:30:00 6.8 0.8 9.5 4.9 6.8 0.9 9.5 4.6 6.4 0.9 9.1 3.8 18 0 18 165 -1.6 0 -1.4 -1.9 11/21/2005 07:40:00 6.2 1.1 9.5 3 6.2 1.1 9.5 3.4 5.5 1.1 8.4 2.6 18 0 18 165 -1.5 0 -1.4 -1.7 11/21/2005 07:50:00 5.5 0.8 8.4 3.4 5.3 1 8 3 5.2 0.9 8 2.6 18 0 18 165 -1.5 0 -1.4 -1.7 11/21/2005 08:00:00 5.8 1.2 8.8 2.6 5.3 1.4 8.8 1.9 5.8 1.2 9.5 3 18 0 18 165 -1.6 0 -1.4 -1.9 11/21/2005 08:10:00 6.9 0.8 8.8 4.9 6.8 1.2 9.1 3.4 7 0.8 8.8 4.6 18 0 18 165 -1.6 0 -1.4 -1.9 11/21/2005 08:20:00 6.6 0.6 8.8 4.6 5.7 1.1 8 3.4 6.6 0.8 9.1 4.9 18 0 18 165 -1.6 0 -1.4 -1.7 11/21/2005 08:30:00 6.1 0.8 8.4 4.6 5.8 0.9 8 3.4 6 0.8 8.4 3.8 18 0 18 165 -1.6 0 -1.4 -1.7 11/21/2005 08:40:00 6.4 0.7 8.8 4.2 6.4 0.8 8.8 4.2 6.2 0.8 8 4.2 18 0 18 165 -1.4 0 -1.2 -1.7 11/21/2005 08:50:00 5.9 0.7 8 4.2 5.8 0.7 7.6 4.2 5.5 0.8 7.6 3.8 18 0 18 165 -1.5 0 -1.4 -1.7 11/21/2005 09:00:00 6.1 0.5 7.2 4.9 6.1 0.5 7.6 4.6 5.1 0.7 7.2 3 18 0 18 165 -1.6 0 -1.4 -1.9 11/21/2005 09:10:00 5.8 0.8 7.6 3.4 5.7 0.8 7.6 3.4 5.3 0.9 7.2 3.4 18 0 18 165 -1.6 0 -1.4 -1.9 11/21/2005 09:20:00 6 0.7 7.6 4.2 6 0.7 7.6 4.6 5.4 0.9 8 3.4 18 0 18 165 -1.7 0 -1.4 -1.9 11/21/2005 09:30:00 5.1 0.7 6.8 3.4 5 0.7 6.8 3 5 0.7 6.8 3.4 18 0 18 165 -1.8 0 -1.7 -1.9 11/21/2005 09:40:00 5 0.7 6.8 3.8 5 0.7 7.2 3.4 4.7 0.6 6.5 3.4 18 0 18 165 -2 0 -1.9 -2.1 11/21/2005 09:50:00 4.3 0.5 5.7 2.6 4.2 0.5 5.3 2.3 4 0.5 5.3 2.6 18 0 18 165 -2.1 0 -1.9 -2.1 11/21/2005 10:00:00 4.2 0.6 6.1 2.6 4.1 0.6 5.7 2.6 3.8 0.7 5.3 2.3 18 0 18 165 -2.1 0 -1.9 -2.4 11/21/2005 10:10:00 5.1 0.7 6.8 3 5.1 0.7 6.8 3 4.5 0.7 6.5 2.6 18 0 18 165 -1.8 0 -1.7 -2.1 11/21/2005 10:20:00 5.1 0.6 6.8 3.4 5.1 0.6 6.8 3.8 4.4 0.6 6.1 2.6 18 0 18 165 -1.5 0.1 -1.2 -1.9 11/21/2005 10:30:00 6 0.8 7.6 4.2 6 0.7 7.6 3.8 4.7 0.6 6.5 3 18 0 18 165 -1.4 0 -1.2 -1.7 11/21/2005 10:40:00 6.7 0.9 9.1 3.4 6.6 0.9 9.1 3.4 5.2 0.9 7.6 3.4 18 0 18 165 -1.4 0 -1.2 -1.7 11/21/2005 10:50:00 7.2 0.8 8.8 4.6 7.1 0.8 8.4 4.6 5.8 0.7 7.2 4.2 18 0 18 165 -1.4 0 -1.2 -1.4 11/21/2005 11:00:00 7.7 0.5 9.1 6.1 7.6 0.5 8.8 6.1 6.5 0.8 8.4 4.2 18 0 18 165 -1.5 0 -1.4 -1.7 11/21/2005 11:10:00 7.5 0.7 9.5 5.3 7.4 0.7 9.1 5.3 6.9 1 9.1 4.2 18 0 18 165 -1.4 0 -1.4 -1.7 11/21/2005 11:20:00 7.8 0.6 9.1 5.7 7.7 0.6 9.1 5.7 6.9 0.8 8.8 4.9 17 0 18 165 -1.4 0 -1.4 -1.7 11/21/2005 11:30:00 7.8 0.5 9.1 6.5 7.6 0.5 9.1 6.1 6.1 0.5 8.4 4.6 17 0 18 165 -1.6 0 -1.4 -1.9 11/21/2005 11:40:00 8.2 0.8 10.3 6.5 8.1 0.7 10.3 6.5 7.1 1 9.1 4.2 17 0 18 165 -1.7 0 -1.4 -1.9 11/21/2005 11:50:00 7.1 1.2 9.9 4.9 7 1.2 9.5 4.6 6.1 1.3 9.1 3 17 0 18 165 -1.6 0 -1.4 -1.9 11/21/2005 12:00:00 7.4 0.6 9.1 5.7 7.3 0.6 8.8 5.7 5.9 1 7.6 3.8 17 0 18 165 -1.4 0 -1.2 -1.7 11/21/2005 12:10:00 6.5 0.6 8 4.6 6.4 0.6 8 4.6 5.7 0.9 7.2 3.4 17 0 17 165 -1.4 0 -1.2 -1.4 11/21/2005 12:20:00 7 0.5 8.4 5.3 6.9 0.5 8.4 5.3 5.6 1 8 3.8 17 0 17 165 -1.4 0 -1.4 -1.7 11/21/2005 12:30:00 7.5 0.6 9.1 6.1 7.4 0.6 8.8 6.1 5.9 0.9 8.4 3.8 17 0 17 165 -1.6 0 -1.4 -1.7 11/21/2005 12:40:00 7.8 1 10.3 5.7 7.7 1 10.3 4.9 5.9 0.9 8.8 3.8 12 18 293 165 -1.5 0 -1.4 -1.9 11/21/2005 12:50:00 9.4 0.8 11.1 6.8 9.4 0.8 11.1 6.8 6.4 0.7 8.4 4.6 302 4 301 165 -1.6 0 -1.4 -1.9 11/21/2005 13:00:00 7 1 9.9 4.6 7 1 9.9 4.6 5.5 0.8 8 3.4 301 8 298 165 -1.6 0 -1.4 -1.7 11/21/2005 13:10:00 6 1.2 9.1 1.5 6 1.2 8.8 1.5 5.1 1.2 8.4 2.3 301 14 316 165 -1.6 0 -1.4 -1.9 11/21/2005 13:20:00 6.1 0.9 8.8 3.8 6 0.9 8.8 3.4 5.2 0.9 7.6 2.6 310 11 302 165 -1.5 0 -1.4 -1.9 11/21/2005 13:30:00 5.7 0.6 7.2 4.2 5.7 0.6 7.2 3.4 5 0.9 6.8 3 296 13 307 165 -1.5 0 -1.4 -1.7 11/21/2005 13:40:00 6.6 0.6 8 4.9 6.6 0.6 8 4.9 5.9 0.9 8.4 3.4 291 6 290 165 -1.7 0 -1.4 -1.9 11/21/2005 13:50:00 6.6 0.6 8 5.3 6.6 0.6 8 5.3 5.7 0.9 7.6 3.4 290 4 293 165 -1.7 0 -1.7 -1.9 11/21/2005 14:00:00 7 0.6 8.8 5.7 7 0.6 8.4 5.3 5.7 0.8 7.6 3.8 292 6 291 165 -1.7 0 -1.7 -1.9 11/21/2005 14:10:00 7.2 0.5 8.4 5.7 7.2 0.5 8.4 5.3 5.3 0.8 8 3.8 298 4 296 165 -1.7 0 -1.4 -1.9 11/21/2005 14:20:00 6.9 0.5 8 5.3 6.9 0.5 8 4.9 4.9 0.5 6.5 3.8 299 4 306 165 -1.7 0 -1.7 -1.9 11/21/2005 14:30:00 7.8 0.6 9.1 6.5 7.8 0.6 9.1 6.5 5.7 0.6 7.6 4.2 298 5 295 165 -1.9 0 -1.7 -1.9 11/21/2005 14:40:00 7.1 0.6 8.8 5.3 7 0.6 8.8 4.9 5.7 0.8 8 4.2 306 6 307 165 -2 0 -1.9 -2.1 11/21/2005 14:50:00 7.3 0.6 9.1 4.9 7.2 0.6 9.1 4.6 5.4 0.8 7.6 3.8 303 5 302 165 -2 0 -1.9 -2.1 11/21/2005 15:00:00 6.3 0.8 8 3.8 6.3 0.7 7.6 4.2 4.9 0.6 6.5 3.4 305 6 300 165 -2 0 -1.9 -2.1 11/21/2005 15:10:00 5.7 0.6 7.2 3.8 5.7 0.6 7.2 3.8 4.5 0.6 6.1 3 304 9 295 165 -2 0 -1.9 -2.1 11/21/2005 15:20:00 5.7 0.8 7.6 3.4 5.7 0.8 7.6 3.4 4.9 1 7.6 2.6 299 9 302 165 -2 0 -1.9 -2.1 11/21/2005 15:30:00 6.4 1 8.4 3.8 6.4 1.1 8.8 3.8 5.3 1 8.4 3 297 9 292 165 -2 0 -1.9 -2.1 11/21/2005 15:40:00 7.7 0.5 8.8 6.5 7.7 0.5 8.8 6.5 6 0.8 8.4 4.2 305 5 305 165 -2.1 0 -1.9 -2.1 11/21/2005 15:50:00 7.7 0.5 8.8 6.1 7.6 0.5 8.8 6.1 6.9 0.8 8.4 4.6 312 3 310 165 -2.1 0 -1.9 -2.4 11/21/2005 16:00:00 6.9 0.7 8.8 4.9 6.9 0.8 8.8 4.9 5.9 0.8 8 3.4 309 5 314 165 -2.1 0 -1.9 -2.4 11/21/2005 16:10:00 7.2 0.9 9.1 4.6 7.2 0.9 9.1 4.9 5.5 0.9 8.4 3.4 303 6 304 165 -2.2 0 -2.1 -2.4 11/21/2005 16:20:00 8.3 0.7 9.9 6.5 8.3 0.7 9.5 6.1 5.9 0.7 8.4 3.8 302 5 298 165 -2.4 0 -2.1 -2.6 11/21/2005 16:30:00 8 0.8 9.9 6.5 8 0.8 9.5 6.1 6.3 0.7 8.4 4.2 305 5 300 165 -2.5 0 -2.4 -2.6 11/21/2005 16:40:00 8.4 0.9 10.7 6.1 8.4 0.9 10.3 6.5 6.8 1 9.9 4.2 305 6 312 165 -2.6 0 -2.6 -2.8 11/21/2005 16:50:00 9 1 10.7 6.5 8.9 0.9 11.1 6.5 8 1 10.3 4.9 309 5 309 165 -2.8 0 -2.6 -2.8 11/21/2005 17:00:00 8.9 0.8 10.7 6.8 8.8 0.8 10.7 7.2 7.3 1 9.5 4.9 308 6 307 165 -2.9 0 -2.8 -3 11/21/2005 17:10:00 8.6 0.7 10.3 6.8 8.6 0.6 10.3 6.8 6.4 0.8 9.1 4.6 302 5 296 165 -3 0 -2.8 -3.3 11/21/2005 17:20:00 8.8 0.8 10.7 6.5 8.8 0.8 11.1 6.5 6.2 0.8 8.8 4.6 299 5 296 165 -3 0 -2.8 -3 11/21/2005 17:30:00 7.9 0.8 10.3 5.7 7.9 0.8 10.3 5.7 6.1 0.9 8.8 4.2 304 5 301 165 -3 0 -2.8 -3.3 11/21/2005 17:40:00 8.1 0.9 11.8 6.1 8.1 0.9 11.8 6.5 6 1 10.7 4.6 300 6 288 165 -3 0 -2.8 -3 11/21/2005 17:50:00 9.9 0.8 11.8 8 10 0.8 11.8 8.4 7.1 1 10.7 5.3 299 5 292 165 -3 0 -3 -3.3 11/21/2005 18:00:00 9.2 0.8 11.1 7.2 9.3 0.8 11.1 7.2 7.1 1 11.1 4.9 298 6 296 165 -3 0 -2.8 -3.3 11/21/2005 18:10:00 8 1 10.3 5.7 8 1 10.7 5.7 6.2 1 9.1 4.2 300 6 296 165 -3.2 0 -3 -3.3 11/21/2005 18:20:00 8.1 0.9 10.3 6.1 8.2 0.9 10.7 6.1 6.4 0.9 9.1 4.6 301 7 302 165 -3.3 0 -3.3 -3.5 11/21/2005 18:30:00 10.1 1 13 6.8 10.1 1 13 7.2 7.8 1 12.2 4.9 303 6 310 165 -3.4 0.1 -3.3 -3.5 11/21/2005 18:40:00 9.3 0.8 11.5 6.8 9.3 0.8 11.8 7.2 7.8 1.1 10.7 4.9 307 5 307 165 -3.6 0 -3.5 -3.7 11/21/2005 18:50:00 10.6 0.8 12.6 8 10.6 0.8 13 8 9.8 1 12.2 6.8 312 6 311 165 -3.6 0 -3.5 -3.9 11/21/2005 19:00:00 9.7 1 11.8 7.2 9.7 1 11.8 7.2 8.7 1.1 11.5 5.7 311 4 309 165 -3.8 0 -3.5 -3.9 11/21/2005 19:10:00 9.7 0.8 11.5 8 9.7 0.8 11.8 7.6 8.7 1.1 11.8 6.1 312 5 313 165 -3.7 0 -3.5 -4.2 11/21/2005 19:20:00 9.6 1 12.2 6.8 9.6 1 12.2 7.2 8.2 1.1 11.5 6.1 309 5 307 165 -3.8 0 -3.5 -3.9 11/21/2005 19:30:00 9.6 0.8 12.2 8 9.6 0.8 11.8 8 7.4 1.1 10.3 5.3 303 6 307 165 -3.8 0 -3.5 -4.2 11/21/2005 19:40:00 9.9 1.1 12.6 6.8 9.9 1.1 13 6.5 8.6 1.2 12.2 6.1 309 6 307 165 -3.7 0 -3.5 -3.9 11/21/2005 19:50:00 10.4 1 12.6 7.6 10.3 1 12.6 7.2 8.2 1.3 11.5 5.7 305 6 302 165 -3.9 0 -3.7 -4.2 11/21/2005 20:00:00 11.2 1.1 14.1 8 11.2 1 13.7 8 8.9 1.4 13 6.1 306 6 301 165 -4.1 0 -3.9 -4.4 11/21/2005 20:10:00 11 1.4 14.1 8 11 1.4 14.1 8 8.3 1.2 12.2 5.7 305 6 300 165 -4.1 0.1 -3.9 -4.2 11/21/2005 20:20:00 12.2 1 14.9 9.1 12.1 1 14.9 9.1 10.6 1.2 13.7 7.2 310 4 312 165 -4.2 0 -3.9 -4.4 11/21/2005 20:30:00 12.3 1 14.5 9.1 12.2 1 14.5 9.1 10.2 1.3 13 7.2 308 5 304 165 -4.1 0 -3.9 -4.4 11/21/2005 20:40:00 11.9 1 14.1 9.1 11.8 1 13.7 8.8 9.4 1.3 13 6.5 306 6 306 165 -4.2 0 -3.9 -4.4 11/21/2005 20:50:00 11.7 0.8 13.7 9.5 11.6 0.8 13.7 9.5 8.8 1 11.8 6.5 304 4 302 165 -4.4 0.2 -4.2 -4.6 11/21/2005 21:00:00 10.7 1.1 13.3 8.4 10.6 1.1 13.3 8.4 8.6 1.5 12.6 5.7 307 6 308 165 -4.7 0 -4.6 -4.8 11/21/2005 21:10:00 12.2 1 14.5 8.8 12.2 1 14.5 9.1 10.1 1.3 13 6.8 308 5 308 165 -4.7 0 -4.6 -5 11/21/2005 21:20:00 12 0.9 14.1 9.5 11.9 0.9 14.1 9.5 9.7 1.2 13 6.1 307 4 305 165 -4.6 0 -4.4 -4.8 11/21/2005 21:30:00 11.6 1 14.1 9.1 11.5 1 13.7 9.1 9.6 1.4 13 6.5 307 4 317 165 -4.7 0 -4.6 -4.8 11/21/2005 21:40:00 11.8 0.9 14.1 9.5 11.7 0.9 13.7 9.5 10.3 1.3 13 7.2 310 5 309 165 -4.7 0 -4.6 -4.8 11/21/2005 21:50:00 12.1 1.1 14.9 9.9 12 1.1 14.5 9.5 11.1 1.3 14.1 7.6 311 5 309 165 -4.7 0 -4.4 -4.8 11/21/2005 22:00:00 12.9 1 14.9 10.3 12.8 1 14.9 10.3 12.5 0.9 14.9 9.9 314 4 314 165 -4.7 0 -4.6 -4.8 11/21/2005 22:10:00 11.6 1.5 14.9 8.4 11.4 1.5 14.5 8.4 11.2 1.6 14.5 8 315 5 315 165 -4.8 0 -4.6 -5 11/21/2005 22:20:00 12 1.3 14.9 9.5 11.8 1.3 14.9 9.1 11.6 1.3 14.9 8.8 316 5 307 165 -4.8 0 -4.6 -5.3 11/21/2005 22:30:00 13.4 1 15.6 10.3 13.2 0.9 15.6 10.3 11.9 1.4 14.5 8.4 311 5 310 165 -4.8 0 -4.6 -5 11/21/2005 22:40:00 14.1 1.6 18.3 10.7 13.9 1.6 17.9 10.7 12.6 1.6 17.2 9.1 310 5 313 165 -4.8 0.1 -4.6 -5 11/21/2005 22:50:00 13.7 1 16.1 11.1 13.5 1 16.1 11.1 11.9 1.2 14.9 8.4 308 5 305 165 -4.7 0 -4.6 -4.8 11/21/2005 23:00:00 14.2 1.3 17.2 11.1 14 1.3 17.2 10.7 11.9 1.6 16.1 8 307 5 305 165 -4.7 0 -4.6 -5 11/21/2005 23:10:00 14.2 1 17.2 11.1 14.1 1 16.8 11.1 10.8 1.7 16.1 7.6 304 5 304 165 -4.7 0 -4.6 -5 11/21/2005 23:20:00 13.7 1 16.4 10.3 13.5 1 16.4 10.7 10.4 1.3 14.1 7.6 304 5 298 165 -4.7 0 -4.6 -4.6 11/21/2005 23:30:00 13.6 0.9 16.1 11.5 13.5 0.9 16.1 11.5 9.6 1.1 13 7.6 303 4 304 165 -4.7 0.1 -4.4 -4.8 11/21/2005 23:40:00 12.8 1.1 15.3 9.9 12.7 1 15.3 9.9 9.2 1 12.6 6.8 302 5 289 165 -4.7 0 -4.6 -4.8 11/21/2005 23:50:00 12.4 1 15.3 9.9 12.3 0.9 14.9 9.9 9 1 11.8 6.5 303 4 309 165 -4.8 0 -4.6 -5 11/22/2005 00:00:00 11.6 0.8 13.3 9.5 11.5 0.8 13 9.5 9.2 1 11.8 6.5 307 5 303 165 -4.9 0 -4.6 -5 11/22/2005 00:10:00 11.4 0.8 13.3 9.5 11.3 0.8 13.3 9.5 8.9 1.1 11.8 6.1 306 4 307 165 -4.9 0 -4.6 -5.3 11/22/2005 00:20:00 11.1 0.7 13 9.5 11 0.8 12.6 9.1 8.8 1.1 11.8 6.5 306 4 309 165 -4.8 0 -4.6 -5 11/22/2005 00:30:00 11.7 0.8 13 9.5 11.6 0.8 13.3 9.9 7.9 0.9 11.1 5.7 302 3 302 165 -4.8 0 -4.6 -5 11/22/2005 00:40:00 11.9 0.9 13.3 9.5 11.8 0.9 13.3 9.1 8.5 0.9 11.1 6.5 304 4 302 165 -4.8 0 -4.6 -5 11/22/2005 00:50:00 11.3 0.9 13.3 8.8 11.2 0.9 13.3 8.8 8.8 1 11.5 6.5 305 4 303 165 -4.9 0 -4.6 -5 11/22/2005 01:00:00 11.5 0.7 13.7 9.1 11.4 0.7 13 9.1 8.7 1.1 11.8 6.1 305 4 307 165 -4.8 0 -4.6 -5 11/22/2005 01:10:00 11.5 0.6 13 9.5 11.5 0.7 13 9.5 9.6 1 11.8 6.5 308 4 308 165 -4.8 0 -4.6 -5 11/22/2005 01:20:00 11.6 0.7 13.7 9.5 11.6 0.6 13.3 9.5 8.6 1.3 11.8 6.1 304 3 307 165 -4.8 0 -4.6 -5 11/22/2005 01:30:00 11.7 0.9 13.7 9.5 11.7 0.9 13.3 9.5 8.2 0.7 10.3 6.5 303 4 300 165 -4.7 0 -4.4 -5 11/22/2005 01:40:00 10.8 0.7 12.2 9.1 10.8 0.7 12.2 9.1 7.4 0.9 10.3 5.7 299 3 292 165 -4.8 0 -4.6 -5 11/22/2005 01:50:00 10.7 0.5 12.2 9.1 10.7 0.5 12.2 9.1 7 0.7 9.9 5.7 301 3 299 165 -4.9 0 -4.6 -5.3 11/22/2005 02:00:00 10.2 0.6 11.5 8.8 10.2 0.6 11.5 8.8 6.7 0.6 8.4 5.3 301 2 301 165 -5 0 -4.8 -5.3 11/22/2005 02:10:00 10.5 0.7 12.2 8.4 10.5 0.7 12.2 8.4 6.8 0.6 9.1 5.3 301 2 300 165 -5 0 -4.8 -5.3 11/22/2005 02:20:00 10 0.6 11.5 8.8 10 0.6 11.5 8.4 6.6 0.5 8.4 4.9 302 2 301 165 -5 0 -4.8 -5.3 11/22/2005 02:30:00 9.5 0.4 10.7 8 9.4 0.4 10.7 8 7.5 0.9 9.1 5.3 307 4 298 165 -5 0 -5 -5.3 11/22/2005 02:40:00 8.8 0.6 10.3 6.8 8.6 0.6 10.3 6.5 8.1 0.5 9.1 6.5 314 4 307 165 -5.2 0.2 -4.8 -5.5 11/22/2005 02:50:00 7.9 0.7 9.5 5.7 7.8 0.7 9.1 5.7 7.6 0.6 8.8 6.1 317 5 310 165 -5.4 0 -5.3 -5.7 11/22/2005 03:00:00 8 1 11.1 5.7 7.9 1 11.1 5.3 6.7 1 9.5 4.6 309 6 309 165 -5.4 0.1 -5.3 -5.7 11/22/2005 03:10:00 9.3 0.8 10.7 7.2 9.2 0.8 10.7 7.2 7.8 0.9 9.9 4.9 310 5 309 165 -5.3 0 -5 -5.5 11/22/2005 03:20:00 9.3 0.7 10.7 7.6 9.2 0.7 10.7 7.6 7 0.7 9.1 5.3 305 3 302 165 -5.3 0 -5.3 -5.5 11/22/2005 03:30:00 9.9 0.6 11.1 8.8 9.8 0.6 11.1 8.4 7.5 0.7 8.8 5.7 306 3 299 165 -5.3 0 -5.3 -5.7 11/22/2005 03:40:00 9.8 0.4 10.7 8.8 9.8 0.4 10.7 8.8 7 0.7 9.5 5.7 304 3 304 165 -5.4 0 -5.3 -5.5 11/22/2005 03:50:00 10 0.4 11.1 8.8 9.9 0.5 11.1 8.4 7 0.6 9.9 5.3 304 3 302 165 -5.4 0 -5.5 -5.7 11/22/2005 04:00:00 9.4 0.7 11.5 7.6 9.4 0.7 11.5 7.6 6.6 0.7 9.1 4.9 302 3 302 165 -5.4 0 -5.3 -5.5 11/22/2005 04:10:00 9 0.6 10.3 7.6 9 0.6 10.3 7.6 7.1 0.7 8.8 5.3 306 3 305 165 -5.4 0 -5.3 -5.5 11/22/2005 04:20:00 8.9 0.5 9.9 7.2 8.8 0.6 9.9 7.2 7.8 0.6 9.1 5.7 310 3 306 165 -5.4 0 -5.3 -5.7 11/22/2005 04:30:00 8.7 0.6 9.9 6.8 8.6 0.6 10.3 6.8 7.9 0.6 9.5 6.5 312 3 310 165 -5.5 0 -5.5 -5.7 11/22/2005 04:40:00 8 0.6 9.1 6.5 7.9 0.6 9.1 6.1 7.4 0.7 8.8 5.7 314 3 312 165 -5.7 0 -5.5 -5.7 11/22/2005 04:50:00 8.5 0.6 10.7 6.8 8.4 0.6 10.3 6.8 7.8 0.8 9.9 5.7 313 4 313 165 -5.6 0 -5.5 -5.7 11/22/2005 05:00:00 8.2 0.9 9.9 6.1 8.1 0.9 9.9 5.7 7.2 1 9.1 3.8 311 4 307 165 -5.4 0 -5.3 -5.7 11/22/2005 05:10:00 7.8 0.8 9.9 6.1 7.7 0.8 9.5 6.1 6.5 1 8.8 4.2 310 4 313 165 -5.5 0 -5.5 -5.7 11/22/2005 05:20:00 7.3 0.9 10.7 4.9 7.2 0.9 10.3 4.9 5.8 1 9.1 3.8 306 6 310 165 -5.5 0.1 -5.3 -5.9 11/22/2005 05:30:00 6.3 0.8 8.4 4.2 6.3 0.8 8.4 4.6 5.1 0.9 7.2 3.4 307 6 306 165 -5.5 0 -5.5 -5.7 11/22/2005 05:40:00 4.5 0.7 6.5 3 4.5 0.7 6.5 3 3.8 0.7 5.7 2.3 308 8 316 165 -5.7 0.1 -5.5 -5.7 11/22/2005 05:50:00 3.9 0.5 5.3 3 3.9 0.5 5.3 2.6 3.2 0.5 4.9 1.9 300 9 292 165 -5.9 0 -5.7 -6.1 11/22/2005 06:00:00 4.2 0.6 6.1 3 4.2 0.6 5.7 2.6 3.5 0.6 5.3 2.3 303 7 310 165 -5.9 0 -5.7 -5.9 11/22/2005 06:10:00 4.2 0.5 5.7 3 4.2 0.5 6.1 3 3.6 0.6 4.9 2.3 306 7 300 165 -5.9 0 -5.7 -6.1 11/22/2005 06:20:00 4.7 0.5 5.7 3.8 4.7 0.5 5.7 3.4 3.7 0.6 5.3 2.6 305 6 310 165 -5.8 0 -5.7 -5.9 11/22/2005 06:30:00 5.5 0.4 6.8 4.6 5.4 0.4 6.8 4.2 4.6 0.6 6.8 3 309 4 310 165 -5.8 0 -5.7 -5.9 11/22/2005 06:40:00 6.1 0.7 8 4.6 6 0.6 7.6 4.6 5.2 0.8 7.2 3.4 309 6 312 165 -5.9 0 -5.5 -6.1 11/22/2005 06:50:00 6.1 0.7 8.4 4.2 6 0.7 8 4.6 5.9 0.7 8 4.6 320 7 321 165 -5.6 0.1 -5.5 -5.9 11/22/2005 07:00:00 6 0.8 8.4 4.6 5.9 0.8 8.4 4.2 5.6 0.7 7.6 4.2 317 6 307 165 -5.9 0 -5.7 -6.1 11/22/2005 07:10:00 8.1 0.6 10.3 6.5 7.9 0.6 10.3 6.5 7.1 0.6 9.1 4.6 312 4 309 165 -5.9 0.1 -5.7 -6.1 11/22/2005 07:20:00 7.6 0.8 9.5 5.7 7.5 0.8 9.1 5.7 6.4 0.8 8.4 4.6 311 6 308 165 -5.8 0 -5.5 -5.9 11/22/2005 07:30:00 5.9 0.6 8 4.2 5.9 0.6 7.6 3.8 5.2 0.8 6.8 3.4 313 9 310 165 -5.4 0 -5.3 -5.7 11/22/2005 07:40:00 4.8 0.5 6.5 3.8 4.7 0.5 6.8 3.4 4.2 0.7 6.1 2.6 314 9 338 165 -5.6 0.2 -5.3 -5.9 11/22/2005 07:50:00 3.6 0.7 6.1 2.3 3.6 0.8 6.1 1.9 3.3 0.6 5.3 1.9 319 11 315 165 -6 0 -5.7 -6.1 11/22/2005 08:00:00 2.5 0.4 3.4 1.5 2.2 0.5 3.4 0.7 2.3 0.4 3 1.1 337 17 311 165 -6 0 -5.7 -6.4 11/22/2005 08:10:00 3.4 0.6 4.6 1.5 2.4 0.8 4.9 0.7 3.2 0.7 4.6 1.5 355 6 351 165 -6 0 -5.7 -6.1 11/22/2005 08:20:00 4.1 0.4 4.9 3.4 3.4 0.8 5.3 1.5 4 0.4 4.9 3 350 4 349 165 -6.4 0.1 -6.1 -6.6 11/22/2005 08:30:00 4.7 0.6 6.8 3.8 3.7 1.2 7.2 1.5 4.5 0.6 6.8 3.4 352 6 347 165 -6.6 0 -6.6 -6.8 11/22/2005 08:40:00 5.3 0.9 7.6 4.2 5.2 0.9 8 3.4 5.1 0.8 7.6 4.2 343 6 338 165 -6.1 0.2 -5.7 -6.8 11/22/2005 08:50:00 5.1 0.5 6.1 3.8 5.1 0.5 6.1 3.8 5 0.5 6.1 3.8 339 7 341 165 -6 0.2 -5.7 -6.4 11/22/2005 09:00:00 5 0.6 7.2 3.8 4.8 0.8 7.2 2.6 5 0.6 6.8 3.8 342 8 351 165 -5.7 0.1 -5.5 -5.9 11/22/2005 09:10:00 4.9 0.7 6.8 3.4 4.8 0.7 6.5 3 4.7 0.6 6.8 3.4 335 11 322 165 -5.8 0 -5.5 -6.1 11/22/2005 09:20:00 5.5 1 7.2 2.6 5.3 1.1 7.6 1.9 5.1 0.8 7.6 2.6 338 9 338 165 -5.4 0.1 -5.3 -5.7 11/22/2005 09:30:00 5.2 1.1 8.4 3.4 4.7 1.5 7.6 1.9 4.9 1 7.6 3 341 15 339 165 -5.3 0 -5.3 -5.5 11/22/2005 09:40:00 5.3 0.9 8 3.8 4.2 1.5 8 1.9 5.3 0.7 7.6 3.8 354 8 340 165 -5.4 0 -5.3 -5.5 11/22/2005 09:50:00 4.7 0.5 6.1 3 3.4 0.8 5.3 1.5 4.4 0.5 6.1 3 357 9 357 165 -5.3 0 -5.3 -5.5 11/22/2005 10:00:00 4.9 0.8 7.2 3.4 4.4 1.3 6.8 1.5 4.6 0.7 6.5 2.6 346 10 325 165 -5.3 0 -5 -5.5 11/22/2005 10:10:00 5.2 0.9 8 3 4.9 1.1 8.4 2.3 4.9 0.9 7.6 2.6 343 8 335 165 -5 0 -4.8 -5.5 11/22/2005 10:20:00 5.5 0.8 7.2 3.4 5.4 0.8 7.6 3 5.2 0.7 6.8 3.4 341 6 330 165 -4.9 0 -4.8 -5.3 11/22/2005 10:30:00 6.2 0.8 8.8 4.6 5.9 1 8.8 3 5.8 0.6 8.4 4.6 343 9 334 165 -5 0 -4.8 -5.3 11/22/2005 10:40:00 7.1 0.9 9.1 4.6 7.1 1 9.5 4.2 6.8 1 9.5 4.6 337 8 348 165 -5 0 -4.8 -5.3 11/22/2005 10:50:00 7.2 0.9 9.5 4.6 7.2 0.9 9.5 4.6 6.8 0.9 9.1 4.2 336 7 332 165 -5 0 -4.8 -5.3 11/22/2005 11:00:00 7.5 0.9 9.5 5.3 7.3 1 10.3 4.6 7.2 0.8 9.5 5.3 341 8 338 165 -5 0 -5 -5.3 11/22/2005 11:10:00 7.1 1 9.9 5.3 7.1 1 9.9 5.3 6.6 1 9.5 4.9 339 5 339 165 -5 0 -4.8 -5.3 11/22/2005 11:20:00 6.8 0.9 9.1 4.6 6.4 1 9.5 3.8 6.1 0.9 8.8 3.8 346 7 347 165 -4.9 0 -4.6 -5 11/22/2005 11:30:00 7 0.8 9.1 4.6 6.9 1 9.1 3.4 6.6 0.9 8.8 3.8 338 9 336 165 -4.7 0 -4.6 -5 11/22/2005 11:40:00 7.2 1.1 9.9 4.6 7.1 1.2 10.3 3.8 6.7 1.1 9.5 3.8 340 7 346 165 -4.5 0 -4.4 -4.6 11/22/2005 11:50:00 7.7 1.3 11.1 4.6 7.4 1.4 11.1 4.2 7.3 1.3 10.3 4.2 339 9 339 165 -4.4 0 -4.4 -4.6 11/22/2005 12:00:00 8.2 1.1 11.1 5.3 8 1.3 10.7 3.8 7.8 1.1 10.3 4.9 343 7 339 165 -4.3 0 -4.2 -4.6 11/22/2005 12:10:00 9.6 1.2 13.3 6.8 9.5 1.3 13.3 5.7 9 1.2 13 5.3 339 8 348 165 -4.3 0 -4.4 -4.6 11/22/2005 12:20:00 9.9 1.2 13.3 6.1 9.7 1.5 13.7 6.1 9.3 1.2 11.8 5.7 343 8 338 165 -4.3 0 -4.2 -4.6 11/22/2005 12:30:00 9.8 1.3 13 5.3 9.7 1.5 13 4.6 9.1 1.4 12.6 5.7 340 8 344 165 -4.4 0 -4.4 -4.4 11/22/2005 12:40:00 9.9 1.4 13.3 4.9 9.7 1.6 13.3 4.9 9.4 1.2 12.2 5.3 341 8 337 165 -4.3 0 -4.2 -4.4 11/22/2005 12:50:00 8.4 1.3 11.5 5.3 7.8 1.7 11.5 4.2 7.9 1.5 11.5 3.8 345 11 338 165 -4.3 0 -4.2 -4.4 11/22/2005 13:00:00 7 1.7 11.1 2.3 6.6 1.9 10.7 1.5 6.5 1.6 11.1 2.6 342 10 335 165 -4.3 0 -4.2 -4.4 11/22/2005 13:10:00 6.2 1.8 10.3 2.3 5.7 2 10.3 1.5 5.8 1.7 10.3 2.3 341 13 337 165 -4.3 0 -4.2 -4.4 11/22/2005 13:20:00 8.4 1 10.7 4.9 8.2 1.2 11.1 4.2 7.4 1.1 10.3 3.8 343 7 342 165 -4.4 0 -4.4 -4.6 11/22/2005 13:30:00 7.4 1.5 10.3 4.2 7.2 1.7 10.7 3 6.7 1.5 9.9 2.3 341 9 340 165 -4.4 0 -4.2 -4.6 11/22/2005 13:40:00 8.8 1.5 12.2 4.9 8.8 1.6 12.2 4.9 8.4 1.5 11.8 4.9 339 8 339 165 -4.4 0 -4.2 -4.6 11/22/2005 13:50:00 10.5 1.3 13.3 7.2 10.5 1.7 13.3 4.2 10.1 1.3 12.6 6.1 341 6 338 165 -4.5 0 -4.4 -4.6 11/22/2005 14:00:00 10.7 1.1 13.3 8 10.6 1.2 13.3 6.8 10.5 1.1 13.3 7.2 335 7 333 165 -4.5 0 -4.4 -4.6 11/22/2005 14:10:00 11.7 1.2 15.3 8 11.8 1.3 15.3 7.6 11.5 1.3 14.9 7.6 341 6 330 165 -4.5 0 -4.4 -4.6 11/22/2005 14:20:00 11.1 1.2 14.1 8 10.6 1.4 14.1 6.5 10.8 1.3 14.5 6.5 345 7 355 165 -4.5 0 -4.4 -4.8 11/22/2005 14:30:00 8.9 1.4 14.1 6.1 8.6 1.8 14.1 4.2 8.5 1.5 13.7 5.3 345 8 352 165 -4.5 0 -4.4 -4.6 11/22/2005 14:40:00 9.7 1.7 14.1 5.7 9.6 1.8 13.7 3.8 9 1.7 13.3 3.8 332 9 328 165 -4.5 0 -4.4 -4.6 11/22/2005 14:50:00 10.5 1.2 14.1 6.8 10.2 1.7 13.7 5.3 9.9 1.4 14.1 6.5 343 8 330 165 -4.7 0 -4.6 -4.6 11/22/2005 15:00:00 10.4 1.2 13.3 7.2 10.4 1.3 13.7 6.8 10.1 1.4 13.3 6.5 338 7 330 165 -4.6 0 -4.4 -4.6 11/22/2005 15:10:00 11.3 1.1 14.9 8 10.8 1.4 14.1 6.1 11 1.3 15.3 7.6 341 10 3 165 -4.7 0 -4.6 -4.8 11/22/2005 15:20:00 12.2 1.9 16.8 6.8 12.1 2.4 16.8 5.7 12 1.7 16.8 8 342 7 331 165 -4.9 0 -4.6 -5 11/22/2005 15:30:00 11.6 2 16.4 7.2 11.4 2.2 16.8 6.8 11.3 1.9 15.6 6.8 341 8 352 165 -4.9 0 -4.6 -5 11/22/2005 15:40:00 8.5 1.7 13.3 5.3 8.2 2.1 13 3.8 8.5 1.8 13 4.2 334 13 330 165 -5 0 -4.8 -5 11/22/2005 15:50:00 8.3 1.5 13.3 4.9 8.2 1.5 11.8 4.2 8.1 1.4 12.2 5.3 335 10 338 165 -5 0 -4.8 -5.3 11/22/2005 16:00:00 10.3 2.3 15.3 6.5 10.1 2.2 14.9 6.1 10.2 2.4 16.1 6.1 336 9 339 165 -5.1 0 -5 -5.3 11/22/2005 16:10:00 11.5 1.4 15.3 7.6 11.4 1.5 15.3 7.2 11.3 1.5 14.9 6.5 334 9 333 165 -5.2 0 -5 -5.3 11/22/2005 16:20:00 11.7 1.3 15.3 7.6 11.6 1.4 15.6 8 11.5 1.5 16.1 8 332 9 342 165 -5.2 0 -5 -5.3 11/22/2005 16:30:00 11.7 1.5 16.1 7.2 10.9 1.7 15.3 5.7 11.6 1.7 16.4 6.8 342 12 346 165 -5.3 0 -5 -5.5 11/22/2005 16:40:00 10.8 2.2 16.4 4.9 10.7 2.2 16.4 4.9 10.5 2 16.1 6.8 332 11 331 165 -5.3 0 -5.3 -5.5 11/22/2005 16:50:00 11.2 1.5 15.6 6.5 11.1 1.5 15.3 5.7 11.1 1.3 14.9 7.6 338 11 328 165 -5.3 0 -5 -5.5 11/22/2005 17:00:00 11.8 1.7 15.3 6.8 11.4 1.8 16.1 6.1 11.7 1.7 15.6 7.6 341 11 355 165 -5.3 0 -5.3 -5.5 11/22/2005 17:10:00 10.8 1.7 15.3 6.8 10.7 1.8 15.3 6.5 10.6 1.8 14.9 6.8 333 11 313 165 -5.4 0 -5.3 -5.5 11/22/2005 17:20:00 10.8 1.7 15.6 6.8 10.7 1.6 14.9 7.2 10.4 1.7 15.3 6.8 330 13 355 165 -5.4 0 -5.3 -5.7 11/22/2005 17:30:00 10.1 1.5 14.9 5.7 9.9 1.6 14.9 5.3 9.9 1.5 14.1 6.5 331 12 333 165 -5.4 0 -5.3 -5.7 11/22/2005 17:40:00 10.4 1.9 14.9 6.5 10 1.7 14.5 4.9 10.1 1.8 14.5 6.1 333 15 356 165 -5.5 0 -5.5 -5.7 11/22/2005 17:50:00 11.1 1.5 15.6 7.6 10.8 1.4 14.9 7.6 10.8 1.7 14.9 6.5 334 14 352 165 -5.6 0 -5.5 -5.7 11/22/2005 18:00:00 11.2 2 17.6 6.5 11 2.1 17.9 6.1 10.7 2.2 16.1 5.7 329 15 337 165 -5.6 0 -5.5 -5.7 11/22/2005 18:10:00 11.9 2.1 19.5 6.8 11.7 2 19.9 7.2 10.9 2.4 18.3 5.3 320 19 353 165 -5.6 0 -5.5 -5.9 11/22/2005 18:20:00 13.1 2.9 20.6 6.5 12.5 2.8 19.9 7.2 12.5 2.9 19.5 6.1 334 15 348 165 -5.6 0 -5.5 -5.7 11/22/2005 18:30:00 12.6 2.6 20.2 6.5 12.3 2.6 19.5 6.5 12.2 2.8 20.2 5.7 330 17 347 165 -5.5 0 -5.5 -5.7 11/22/2005 18:40:00 12.8 2.1 17.6 7.6 12.6 2.2 17.9 6.1 12.1 2.2 18.7 6.5 328 15 340 165 -5.5 0 -5.5 -5.7 11/22/2005 18:50:00 14.7 2.7 22.6 8 14.5 2.8 22.6 8 13.8 3.1 22.1 7.6 330 15 345 165 -5.4 0 -5.5 -5.7 11/22/2005 19:00:00 13.3 2.3 19.1 8 13.2 2.3 19.1 8.4 12.4 2.4 20.2 8.4 322 17 290 165 -5.4 0 -5.3 -5.5 11/22/2005 19:10:00 13.8 2.2 20.2 8.8 13.6 2.1 19.1 8.4 13.1 2.2 18.7 8 328 15 355 165 -5.4 0 -5.3 -5.5 11/22/2005 19:20:00 13.7 2.1 19.1 8.8 13.7 2.2 19.9 8.4 13.2 2.4 18.7 8 326 13 350 165 -5.3 0 -5.3 -5.7 11/22/2005 19:30:00 14.1 2.5 23.7 8.4 13.8 2.5 21 6.1 13.4 2.3 20.2 7.6 327 15 343 165 -5.3 0 -5 -5.5 11/22/2005 19:40:00 14.8 2.1 21.4 9.5 14.6 2.1 21.4 8.8 14.2 2.2 20.2 8.4 323 13 319 165 -5.3 0 -5 -5.5 11/22/2005 19:50:00 15.5 2.3 21.4 9.9 15.4 2.3 21.4 10.3 13.9 2.2 20.2 8.4 312 12 297 165 -5.2 0 -5 -5.3 11/22/2005 20:00:00 15.3 2.1 21.4 10.7 15.2 2 20.6 10.7 13.7 1.9 19.9 9.5 311 11 291 165 -5.2 0 -5 -5.3 11/22/2005 20:10:00 15.1 1.5 19.5 9.5 15 1.5 19.1 10.7 13.5 1.7 19.9 7.2 310 10 304 165 -5.2 0 -5 -5.3 11/22/2005 20:20:00 14.9 1.8 20.2 9.5 14.8 1.8 19.9 9.9 13.1 1.9 19.1 8.8 309 9 316 165 -5.2 0 -5 -5.3 11/22/2005 20:30:00 15.8 2.5 22.9 10.3 15.7 2.5 22.6 10.3 13.9 2.2 20.2 8.8 310 11 304 165 -5.1 0 -5 -5.3 11/22/2005 20:40:00 16.6 2.1 22.1 9.5 16.5 2.1 22.1 9.5 13.8 2.3 19.5 8.4 306 6 307 165 -5.1 0 -5 -5.3 11/22/2005 20:50:00 16.6 1.5 21 12.2 16.5 1.5 20.6 12.2 14.1 2.1 19.5 9.9 307 8 309 165 -5.3 0 -5 -5.3 11/22/2005 21:00:00 16.1 2 22.1 10.7 16 2 21.8 10.7 13.7 2.5 21.4 8.8 309 8 304 165 -5.3 0 -5 -5.5 11/22/2005 21:10:00 16.8 2.1 24 11.8 16.7 2.1 24.4 11.8 14.5 2.4 22.1 9.9 309 7 307 165 -5.3 0 -5 -5.5 11/22/2005 21:20:00 16.9 1.7 21 12.6 16.8 1.7 21 12.6 14 1.7 20.2 9.1 307 7 307 165 -5.4 0 -5.3 -5.5 11/22/2005 21:30:00 17.5 1.3 21.8 14.1 17.4 1.3 21.4 13.7 15.3 1.9 21.8 9.9 310 5 319 165 -5.4 0 -5.3 -5.5 11/22/2005 21:40:00 17.4 1.5 20.6 12.2 17.3 1.5 20.6 13 14.8 1.7 19.9 10.3 308 6 304 165 -5.4 0 -5.3 -5.5 11/22/2005 21:50:00 18.7 1.5 22.1 14.9 18.7 1.5 22.1 14.9 16 2.1 21 10.7 307 5 310 165 -5.4 0 -5.3 -5.5 11/22/2005 22:00:00 19.9 1.3 24 16.4 19.8 1.3 23.7 16.4 17.3 1.7 22.6 12.6 308 4 298 165 -5.4 0 -5.3 -5.5 11/22/2005 22:10:00 19.5 1.3 22.1 16.1 19.5 1.3 22.1 16.1 17.1 1.7 20.6 12.6 309 4 307 165 -5.5 0 -5.5 -5.7 11/22/2005 22:20:00 19.1 1.3 22.9 14.5 19 1.3 22.6 14.1 16.6 1.7 21 12.6 309 4 305 165 -5.6 0 -5.5 -5.7 11/22/2005 22:30:00 19.3 1.2 24 14.9 19.3 1.2 23.7 14.1 16.7 1.7 23.3 11.5 309 5 315 165 -5.8 0 -5.5 -5.7 11/22/2005 22:40:00 18.7 1.5 22.6 14.9 18.6 1.5 22.6 14.5 16.8 1.7 21.4 11.8 311 5 300 165 -5.8 0 -5.7 -5.7 11/22/2005 22:50:00 18.8 1.3 22.9 14.9 18.7 1.3 22.9 14.5 17.4 1.7 21.4 13 311 5 309 165 -5.8 0 -5.7 -5.9 11/22/2005 23:00:00 18.6 1.7 22.6 14.1 18.5 1.7 22.6 14.5 17.2 1.8 21.4 12.2 311 5 312 165 -5.9 0 -5.7 -6.1 11/22/2005 23:10:00 19.4 1.5 22.9 15.3 19.3 1.5 22.9 14.5 18.4 1.7 22.6 14.1 313 5 308 165 -5.8 0 -5.7 -5.9 11/22/2005 23:20:00 18.3 1.1 21.4 14.9 18.2 1.2 21.4 14.9 17.4 1.4 21.8 12.2 315 5 309 165 -5.9 0 -5.7 -6.1 11/22/2005 23:30:00 17.8 1.2 21.4 14.9 17.7 1.2 21.4 14.5 17 1.5 21.4 13 314 6 312 165 -5.9 0 -5.7 -5.9 11/22/2005 23:40:00 17.8 1 21 14.5 17.7 1 20.6 14.5 16.7 1.5 20.2 11.1 313 5 307 165 -6 0 -5.7 -6.1 11/22/2005 23:50:00 18.4 1.1 22.6 15.6 18.3 1.2 22.1 15.3 17.9 1.3 21.4 13.7 315 5 313 165 -6 0 -5.7 -6.1 11/23/2005 00:00:00 17.9 1.1 20.6 14.1 17.8 1.1 20.6 14.5 17.6 1.1 21.8 14.5 319 6 325 165 -6 0 -5.9 -6.4 11/23/2005 00:10:00 17.8 1.6 22.1 13.7 17.6 1.5 21.8 13.7 17.4 1.6 23.3 13.3 321 8 300 165 -6.1 0 -5.9 -6.1 11/23/2005 00:20:00 17.1 1.5 21.4 12.6 17 1.5 21 12.6 16.6 1.7 21 11.1 321 8 318 165 -6.2 0 -6.1 -6.4 11/23/2005 00:30:00 17.3 1.3 21 14.1 17.2 1.3 21 14.1 16.5 1.4 20.2 12.2 318 7 310 165 -6.2 0 -6.1 -6.4 11/23/2005 00:40:00 16.7 1.7 20.6 12.6 16.5 1.7 20.2 12.2 16.3 1.8 20.6 11.8 321 7 319 165 -6.3 0 -6.1 -6.4 11/23/2005 00:50:00 14.7 1.7 19.1 10.3 14.5 1.7 18.3 9.9 14.2 1.5 18.3 9.5 321 9 317 165 -6.4 0 -6.1 -6.6 11/23/2005 01:00:00 14.8 1.7 18.7 10.7 14.7 1.7 18.7 10.7 14.4 1.7 19.5 10.7 321 8 311 165 -6.4 0 -6.1 -6.4 11/23/2005 01:10:00 16.8 1.4 21 13 16.7 1.4 21.4 13 16.3 1.5 19.9 12.2 319 6 325 165 -6.3 0 -6.1 -6.4 11/23/2005 01:20:00 16 1.6 19.5 11.1 15.9 1.6 19.5 11.5 15.5 1.8 19.9 11.1 319 6 318 165 -6.3 0 -6.1 -6.4 11/23/2005 01:30:00 15.3 1.3 18.7 11.8 15.1 1.2 18.3 11.8 14.6 1.5 18.3 11.1 320 7 315 165 -6.3 0 -6.1 -6.4 11/23/2005 01:40:00 16 1.2 19.1 11.8 15.9 1.2 19.5 11.8 15.3 1.3 18.3 10.7 318 6 308 165 -6.3 0 -6.1 -6.6 11/23/2005 01:50:00 16.8 1 19.5 14.5 16.7 1 18.7 13.7 15.9 1.2 18.7 11.8 314 4 310 165 -6.2 0 -6.1 -6.4 11/23/2005 02:00:00 15.8 1.3 18.7 12.2 15.7 1.3 18.7 11.5 15 1.4 18.3 11.1 315 4 309 165 -6.2 0 -6.1 -6.4 11/23/2005 02:10:00 14 1.2 17.6 10.7 13.9 1.2 17.2 10.3 12.2 1.7 17.2 8.4 310 6 315 165 -6.4 0 -6.1 -6.6 11/23/2005 02:20:00 14.6 1.1 17.9 11.8 14.5 1.1 17.9 11.8 11.9 1.5 16.1 8.4 307 6 299 165 -6.4 0 -6.1 -6.6 11/23/2005 02:30:00 14.7 1.1 17.6 12.2 14.6 1.1 17.2 12.2 12.8 1.7 17.6 8.4 309 6 307 165 -6.5 0 -6.4 -6.6 11/23/2005 02:40:00 14.5 1.3 17.9 11.1 14.4 1.3 17.9 11.1 11.1 1.5 15.6 7.6 303 6 296 165 -6.6 0 -6.6 -6.8 11/23/2005 02:50:00 14.6 1.3 17.2 10.7 14.5 1.3 17.2 10.7 11.6 1.5 16.4 8.4 305 6 302 165 -6.7 0 -6.6 -6.8 11/23/2005 03:00:00 13.9 1.3 16.8 10.7 13.9 1.3 16.8 10.7 11.2 1.7 15.6 7.6 303 6 301 165 -6.7 0 -6.6 -6.8 11/23/2005 03:10:00 11.1 1.3 14.9 7.6 11 1.4 14.9 6.8 9.3 1.3 13 5.7 306 8 304 165 -6.7 0 -6.6 -6.8 11/23/2005 03:20:00 9.5 1.5 13 6.1 9.5 1.5 12.6 6.5 8 1.4 12.6 4.6 300 9 310 165 -6.8 0 -6.6 -6.8 11/23/2005 03:30:00 11.5 1.4 14.1 8 11.5 1.4 14.1 8 9.1 1.6 13.3 5.3 295 6 295 165 -6.5 0 -6.4 -6.8 11/23/2005 03:40:00 10.8 1 13 7.6 10.8 1 13 7.6 8.3 1.3 11.8 4.6 298 6 283 165 -6.5 0 -6.4 -6.6 11/23/2005 03:50:00 11.5 1 13.7 8.4 11.5 1 13.7 8.8 8.9 1.2 12.6 6.5 294 5 290 165 -6.6 0 -6.6 -6.8 11/23/2005 04:00:00 11.2 1 13.3 8.4 11.2 1 13.3 8.4 8.9 1.3 13 6.5 294 6 296 165 -6.7 0 -6.6 -6.8 11/23/2005 04:10:00 10.5 1 12.6 7.2 10.6 1 13 7.6 8.6 1.3 12.2 5.3 291 5 286 165 -6.7 0 -6.6 -6.8 11/23/2005 04:20:00 10.9 1 13 8.4 10.9 1 13 8.4 9 1.2 11.8 6.1 290 5 289 165 -6.7 0 -6.6 -6.8 11/23/2005 04:30:00 10.6 1.2 12.2 6.1 10.6 1.2 12.2 6.5 8.9 1.5 11.8 3.8 288 4 288 165 -6.8 0 -6.6 -6.8 11/23/2005 04:40:00 10.7 0.6 12.2 7.6 10.7 0.7 12.2 7.6 9.1 1.1 11.5 6.1 289 4 287 165 -6.8 0 -6.6 -6.8 11/23/2005 04:50:00 10.3 0.8 11.8 8 10.3 0.8 12.2 8 9 1.1 12.6 6.1 288 5 291 165 -6.8 0 -6.6 -6.8 11/23/2005 05:00:00 9.3 0.6 10.7 6.8 9.4 0.7 10.7 7.2 8.4 1 11.1 5.7 285 4 287 165 -7 0 -6.8 -7 11/23/2005 05:10:00 8.8 0.4 9.5 6.8 8.9 0.4 9.9 6.8 8.6 0.6 9.9 6.5 281 3 279 165 -7.1 0 -6.8 -7.2 11/23/2005 05:20:00 8.8 0.5 10.7 6.8 8.9 0.6 11.1 6.8 8.2 0.9 11.8 6.1 285 4 279 165 -7.2 0 -7 -7.2 11/23/2005 05:30:00 8.1 0.5 9.9 6.8 8.2 0.5 9.9 7.2 6.7 1 9.5 3.8 290 3 286 165 -7.2 0 -7 -7.4 11/23/2005 05:40:00 8.6 0.6 9.9 6.8 8.6 0.6 9.5 6.8 6.8 0.9 9.1 4.2 291 3 290 165 -7.4 0.1 -7.2 -7.4 11/23/2005 05:50:00 7.3 0.6 8.8 6.1 7.4 0.6 9.1 6.1 5.3 0.9 8 3.8 297 4 296 165 -7.7 0.2 -7.2 -8.1 11/23/2005 06:00:00 8 0.6 9.1 6.5 8 0.6 9.1 6.5 5.7 0.8 8 3.8 295 3 295 165 -7.9 0 -7.6 -8.1 11/23/2005 06:10:00 7.4 0.5 8.8 6.1 7.5 0.5 8.8 5.7 5.5 0.6 7.2 4.2 302 5 295 165 -8.1 0 -7.9 -8.3 11/23/2005 06:20:00 7.6 0.5 9.1 6.5 7.6 0.5 8.4 6.1 5.4 0.6 6.8 4.2 301 5 298 165 -8.1 0 -8.1 -8.3 11/23/2005 06:30:00 8.2 0.5 9.5 7.2 8.2 0.5 9.5 6.8 6.4 1 9.5 4.6 293 5 294 165 -8 0 -7.9 -8.1 11/23/2005 06:40:00 8.6 0.5 9.9 6.8 8.6 0.5 9.9 6.8 7.7 0.9 9.5 5.3 285 5 281 165 -8.1 0 -8.1 -8.3 11/23/2005 06:50:00 7.4 0.9 9.1 6.1 7.4 0.9 9.1 6.1 6.4 1 8.8 3.8 292 4 294 165 -8.3 0 -8.1 -8.5 11/23/2005 07:00:00 5.3 0.6 6.8 4.2 5.4 0.6 6.8 4.6 4.2 0.8 6.8 2.6 300 5 289 165 -8.5 0 -8.3 -8.5 11/23/2005 07:10:00 6.7 0.5 8 5.3 6.7 0.6 8 5.3 4.8 0.5 6.5 3.4 303 4 302 165 -8.6 0 -8.5 -8.9 11/23/2005 07:20:00 6.1 0.5 7.2 4.9 6.1 0.5 7.2 4.6 4.7 0.7 6.5 3 301 6 307 165 -8.7 0 -8.5 -8.9 11/23/2005 07:30:00 7.8 0.4 8.8 6.8 7.8 0.4 8.8 6.8 6 0.8 8 4.2 301 5 308 165 -9 0.1 -8.7 -9.1 11/23/2005 07:40:00 7.6 0.7 9.5 5.7 7.7 0.8 9.5 5.7 6.4 1.4 9.1 3.8 290 8 284 165 -9 0 -8.9 -9.1 11/23/2005 07:50:00 8.5 0.9 10.7 6.1 8.6 0.9 10.7 5.7 7.4 0.8 9.5 5.7 289 5 285 165 -9 0 -8.7 -9.1 11/23/2005 08:00:00 8.7 1.5 11.5 5.7 8.7 1.5 11.5 5.7 7.6 1.6 10.7 4.2 291 5 292 165 -8.4 0.1 -8.1 -8.9 11/23/2005 08:10:00 7.5 0.9 10.7 5.7 7.5 0.9 10.3 6.1 6.3 1 9.1 3.8 292 6 301 165 -8.6 0 -8.5 -8.7 11/23/2005 08:20:00 9.1 0.7 11.1 7.2 9.1 0.7 11.1 7.2 6.5 0.8 9.1 4.9 301 4 304 165 -8.6 0 -8.5 -8.7 11/23/2005 08:30:00 9.1 1 11.5 6.8 9.1 1 11.8 6.5 6.7 0.8 9.1 4.2 302 5 304 165 -8.9 0.1 -8.5 -9.1 11/23/2005 08:40:00 8 0.9 10.3 5.7 8.1 1 10.3 5.7 7.3 1.2 9.5 4.2 286 7 304 165 -9 0 -8.9 -9.1 11/23/2005 08:50:00 6.8 0.8 8.8 4.6 6.8 0.8 8.8 4.6 6.2 0.8 8.8 3 285 6 282 165 -9.3 0.1 -9.1 -9.5 11/23/2005 09:00:00 6.6 0.9 8.8 4.6 6.6 0.9 9.1 4.2 5.5 0.9 8 3 291 5 299 165 -9 0.2 -8.7 -9.5 11/23/2005 09:10:00 8 0.7 9.5 5.7 8 0.7 9.5 5.7 7.3 0.8 9.5 4.9 288 4 289 165 -9.6 0 -9.5 -9.7 11/23/2005 09:20:00 7.3 0.8 8.8 4.9 7.4 0.8 8.8 5.3 7.1 1.1 9.9 4.6 285 4 283 165 -9.4 0 -9.3 -9.7 11/23/2005 09:30:00 7.4 0.6 9.5 6.5 7.5 0.7 9.5 6.1 6.4 1 9.5 4.2 292 4 289 165 -9.4 0 -9.3 -9.5 11/23/2005 09:40:00 6.9 0.6 8.4 5.3 7 0.6 8.4 5.3 5.9 1 8 3.8 290 6 287 165 -9.3 0 -9.1 -9.7 11/23/2005 09:50:00 6.7 0.7 8.4 4.9 6.7 0.7 8.8 4.9 5.7 1 8 3.4 288 8 298 165 -9.1 0 -8.9 -9.3 11/23/2005 10:00:00 6.3 0.6 8 4.9 6.4 0.6 8 4.9 5.7 1 8 2.6 287 7 286 165 -9 0.1 -8.7 -9.3 11/23/2005 10:10:00 5.7 0.7 7.2 3.8 5.7 0.8 7.6 3.8 4.9 1.1 7.2 2.6 294 8 285 165 -8.8 0.1 -8.5 -8.9 11/23/2005 10:20:00 6.3 0.6 8.4 4.9 6.3 0.7 8.4 4.9 4.6 0.7 7.2 3 299 5 295 165 -8.5 0 -8.3 -8.7 11/23/2005 10:30:00 6.3 0.8 8 3.8 6.3 0.9 8 3.8 4.8 0.8 6.8 2.6 298 5 297 165 -8.3 0 -8.1 -8.5 11/23/2005 10:40:00 8 1 11.1 5.3 8.1 1 10.7 5.3 7.1 1.2 10.7 4.2 288 7 285 165 -8.5 0.1 -8.3 -8.9 11/23/2005 10:50:00 8 1.5 11.1 4.6 8.2 1.3 11.5 4.9 7.8 1.5 11.8 4.2 277 6 280 165 -8.9 0 -8.7 -8.9 11/23/2005 11:00:00 6.2 1 8.8 3.8 6.2 1 8.4 3.8 5.1 1 8.8 2.6 299 10 288 165 -8.9 0 -8.7 -9.1 11/23/2005 11:10:00 5.9 1 8.8 3.8 6 1.1 8.8 4.2 5.3 1.4 8.8 2.6 290 9 281 165 -8.7 0 -8.5 -8.9 11/23/2005 11:20:00 7.2 0.5 8.4 6.1 7.3 0.5 8.4 6.1 5.7 1.1 8.4 3.8 297 7 293 165 -8.9 0 -8.7 -8.9 11/23/2005 11:30:00 7.2 0.6 9.1 5.7 7.2 0.6 9.1 5.7 6 0.9 9.1 3.8 304 7 305 165 -8.7 0 -8.3 -8.9 11/23/2005 11:40:00 7.1 0.7 8.4 5.3 7.1 0.7 8.4 5.3 6.2 1 8.8 4.2 300 12 302 165 -8.5 0.1 -8.3 -8.7 11/23/2005 11:50:00 7.1 0.6 8.4 5.3 7.1 0.6 8.4 5.7 6.6 0.8 8.4 4.2 286 5 286 165 -8.7 0 -8.5 -8.9 11/23/2005 12:00:00 6.2 0.8 8 3.8 6.3 0.8 8 3.8 5.5 1.2 8 2.6 288 9 276 165 -8.6 0 -8.5 -8.7 11/23/2005 12:10:00 5.5 0.9 7.2 3.4 5.8 0.9 7.6 3.4 5.4 1 7.6 2.6 274 9 276 165 -8.4 0 -8.3 -8.7 11/23/2005 12:20:00 4.8 0.7 6.5 3 4.9 0.6 6.5 3.4 4.5 0.7 6.5 3 280 8 296 165 -8.3 0 -8.3 -8.5 11/23/2005 12:30:00 6.2 1.3 8.4 3.8 6.3 1.3 8.4 3.8 5.3 0.9 8 2.6 287 10 292 165 -8.3 0 -8.3 -8.5 11/23/2005 12:40:00 5.7 0.9 7.6 3.4 5.7 0.9 8 3.4 4.7 0.7 6.5 2.6 303 9 305 165 -8.1 0.1 -7.9 -8.5 11/23/2005 12:50:00 5.5 0.8 7.2 3.4 5.5 0.8 7.2 3 4.6 0.8 6.8 2.6 308 6 302 165 -7.9 0 -7.6 -8.1 11/23/2005 13:00:00 4.7 0.8 6.5 2.6 4.7 0.8 6.5 3 3.8 0.8 6.1 2.3 301 7 299 165 -8 0 -7.9 -8.1 11/23/2005 13:10:00 3.8 0.6 5.3 2.3 3.8 0.6 5.3 2.3 3.2 0.6 4.9 1.5 307 10 326 165 -7.5 0.2 -7 -8.1 11/23/2005 13:20:00 4.3 0.5 5.3 3 4.3 0.5 5.3 3.4 4 0.7 5.7 2.3 303 13 328 165 -7.6 0.2 -7.2 -8.1 11/23/2005 13:30:00 4.6 0.7 6.5 3 4.6 0.7 6.5 3 3.7 0.8 5.7 2.3 294 8 298 165 -8 0 -7.9 -8.1 11/23/2005 13:40:00 5.7 0.7 7.2 3.8 5.7 0.8 7.2 3.4 4.5 0.8 6.5 3 301 6 304 165 -8.1 0 -7.9 -8.3 11/23/2005 13:50:00 6.1 0.6 7.6 4.6 6 0.6 7.6 4.6 5.3 1 6.8 2.6 308 8 304 165 -8.2 0 -8.1 -8.5 11/23/2005 14:00:00 7.6 0.7 9.1 5.7 7.5 0.7 9.1 6.1 7.2 0.8 9.1 4.9 315 5 310 165 -8.2 0 -8.1 -8.5 11/23/2005 14:10:00 7.2 0.6 8.8 5.7 7.1 0.6 8.4 5.7 6.9 0.7 8.8 4.6 313 5 312 165 -8.3 0 -8.1 -8.5 11/23/2005 14:20:00 7.3 0.6 8.8 5.7 7.3 0.6 8.4 5.7 6.4 1.1 8.8 4.2 292 9 301 165 -8.7 0 -8.3 -8.9 11/23/2005 14:30:00 6.7 0.9 8.4 4.2 6.8 0.9 8.4 4.2 6 1.1 8 3 288 6 286 165 -8.9 0 -8.7 -9.1 11/23/2005 14:40:00 5 0.6 6.1 3.4 5 0.6 6.1 3.4 4.1 0.6 5.3 3 299 9 290 165 -8.7 0 -8.5 -8.9 11/23/2005 14:50:00 5.9 0.7 6.8 3.8 5.9 0.7 6.8 3.8 4.8 0.9 6.8 3 306 4 305 165 -8.7 0 -8.5 -8.7 11/23/2005 15:00:00 5.8 0.8 7.6 4.2 5.8 0.8 7.6 4.2 5.4 0.7 7.2 3.8 312 5 311 165 -8.7 0 -8.5 -8.9 11/23/2005 15:10:00 4.3 0.5 5.7 3.4 4.4 0.5 5.7 3.4 3.6 0.6 5.3 1.9 299 9 315 165 -8.5 0.1 -8.3 -8.9 11/23/2005 15:20:00 4.3 0.5 5.3 3 4.4 0.5 5.3 3 3.5 0.5 4.6 2.3 298 8 297 165 -9 0 -8.7 -9.1 11/23/2005 15:30:00 4.1 0.6 6.1 3 4.1 0.6 6.1 3 3.3 0.5 4.9 1.9 306 5 302 165 -8.9 0 -8.7 -9.1 11/23/2005 15:40:00 4.1 0.5 5.3 2.6 4.2 0.5 5.3 2.3 3.3 0.5 5.3 1.9 303 5 307 165 -9.1 0 -8.9 -9.1 11/23/2005 15:50:00 4.2 0.4 5.3 3.4 4.3 0.4 5.3 3.4 3.7 0.6 4.9 2.3 309 5 310 165 -9.2 0 -8.9 -9.3 11/23/2005 16:00:00 3.3 0.4 4.6 2.6 3.4 0.4 4.6 2.6 2.6 0.4 3.8 1.5 300 4 297 165 -9.2 0 -9.1 -9.3 11/23/2005 16:10:00 3.7 0.5 4.9 2.6 3.7 0.5 4.9 2.6 2.9 0.6 4.6 1.5 304 7 313 165 -9.5 0.2 -9.1 -9.7 11/23/2005 16:20:00 3.8 0.6 4.9 2.6 3.8 0.5 4.9 2.6 3.5 0.6 4.6 2.3 316 3 316 165 -10.2 0.1 -9.7 -10.6 11/23/2005 16:30:00 3.2 0.4 3.8 1.9 3.2 0.4 3.8 2.3 2.9 0.3 3.4 2.3 317 9 310 165 -10.6 0.1 -10.4 -10.8 11/23/2005 16:40:00 3.7 0.6 5.3 2.3 3.8 0.6 5.3 2.6 3.7 0.5 4.9 2.6 322 8 310 165 -10.6 0 -10.4 -11 11/23/2005 16:50:00 5.1 0.5 6.5 3.8 5.2 0.5 6.5 3.8 4.6 0.7 6.5 2.6 312 7 316 165 -10.5 0 -10.4 -10.8 11/23/2005 17:00:00 6.4 1 9.1 4.9 6.4 1 8.8 4.6 5.8 1.1 8.4 3.4 312 5 309 165 -10.7 0.1 -10.6 -11 11/23/2005 17:10:00 6.8 0.7 8.8 4.9 6.7 0.7 8.8 4.9 6.5 0.6 8.8 4.9 319 6 316 165 -10.7 0.1 -10.6 -11 11/23/2005 17:20:00 7.1 0.9 8.8 4.9 7 0.8 8.8 4.9 6.9 0.8 8.8 4.9 319 6 318 165 -10.7 0 -10.6 -11 11/23/2005 17:30:00 7.3 0.6 9.1 6.1 7.3 0.6 8.8 5.7 7 0.8 8.8 4.9 317 6 307 165 -10.6 0.1 -10.6 -10.8 11/23/2005 17:40:00 6.5 0.9 8.8 4.6 6.5 0.9 8.4 4.2 6.3 1 8.4 3.4 321 9 324 165 -10.7 0 -10.6 -10.8 11/23/2005 17:50:00 6.6 0.7 8 4.9 6.6 0.7 7.6 4.9 4.9 0.6 7.2 3.4 304 6 297 165 -10.5 0 -10.2 -11 11/23/2005 18:00:00 7.2 0.3 8 6.5 7.3 0.3 8 6.5 5.2 0.5 6.8 4.2 297 3 300 165 -10.5 0 -10.4 -10.8 11/23/2005 18:10:00 6.5 0.6 8 5.3 6.5 0.6 8 5.3 5.1 0.8 6.8 3.4 298 7 293 165 -10.6 0.1 -10.6 -10.8 11/23/2005 18:20:00 5.1 0.5 6.8 4.2 5.1 0.5 6.8 3.8 4.8 0.6 6.5 3.4 315 5 313 165 -10.8 0 -10.6 -11 11/23/2005 18:30:00 4.8 0.6 6.1 3.8 4.9 0.6 6.1 3.8 3.7 0.6 5.3 2.3 304 5 306 165 -10.6 0 -10.4 -11.4 11/23/2005 18:40:00 4.8 0.8 6.8 3.4 4.8 0.8 6.5 3.4 4.4 0.8 6.1 2.6 315 10 311 165 -10.4 0 -10.2 -10.6 11/23/2005 18:50:00 6.7 0.9 8.4 4.6 6.7 0.9 8.4 4.6 4.8 0.8 7.2 3 304 3 305 165 -10.3 0 -10.2 -10.6 11/23/2005 19:00:00 7 0.4 8.4 6.1 7.1 0.4 8.4 6.1 4.7 0.4 6.5 3.4 300 2 301 165 -10.2 0 -10.2 -10.4 11/23/2005 19:10:00 6.1 0.4 6.8 4.6 6.2 0.4 6.8 4.9 4.4 0.5 5.7 3 296 3 294 165 -10.2 0 -10.2 -10.4 11/23/2005 19:20:00 6.3 0.8 8 4.2 6.3 0.8 8 4.6 5.3 0.8 7.2 3.4 286 8 293 165 -10.2 0.2 -9.5 -10.6 11/23/2005 19:30:00 7.2 0.6 8.8 5.3 7.2 0.6 8.8 4.9 5.5 0.8 8 3.4 299 4 295 165 -9.2 0.1 -8.9 -9.7 11/23/2005 19:40:00 6.5 0.4 7.6 5.3 6.5 0.4 7.2 5.7 4.8 0.8 6.8 3.4 298 3 297 165 -9.6 0 -9.3 -9.7 11/23/2005 19:50:00 6.8 0.4 7.6 5.7 6.7 0.4 7.6 5.7 4.9 0.6 6.8 3.4 299 3 298 165 -9.5 0.1 -9.3 -9.7 11/23/2005 20:00:00 6.9 0.6 8.4 5.3 6.9 0.6 8.4 5.7 4.8 0.6 6.8 3.4 300 3 301 165 -9.6 0 -9.5 -9.7 11/23/2005 20:10:00 6.7 0.8 8.4 4.2 6.7 0.8 8.4 4.2 4.9 0.7 6.8 2.6 298 4 300 165 -9.6 0 -9.3 -9.7 11/23/2005 20:20:00 6.3 0.9 8.8 4.2 6.3 0.9 9.1 3.8 4.8 0.9 8.8 2.6 298 7 295 165 -9.5 0 -9.3 -9.7 11/23/2005 20:30:00 7.4 0.8 8.8 5.3 7.4 0.8 8.8 5.3 5.5 0.8 7.2 3.4 301 5 297 165 -9.5 0 -9.3 -9.7 11/23/2005 20:40:00 7 0.8 8.8 4.2 7 0.8 8.4 4.2 5 0.6 6.5 3 301 3 302 165 -9.3 0 -9.1 -9.7 11/23/2005 20:50:00 6.4 0.5 7.6 4.6 6.4 0.6 7.6 4.6 4.7 0.6 6.1 2.6 302 4 307 165 -9.6 0.1 -9.3 -9.7 11/23/2005 21:00:00 5.1 0.9 7.6 3.4 5.1 0.9 7.2 3.4 4.3 0.6 5.7 3 308 9 296 165 -9.6 0 -9.5 -9.7 11/23/2005 21:10:00 3.7 1.1 6.1 1.5 3.7 1.1 5.7 1.5 3.2 0.9 5.3 1.1 296 12 298 165 -9.5 0.1 -9.3 -9.7 11/23/2005 21:20:00 3.4 0.5 4.6 2.3 3.5 0.5 4.6 2.3 2.9 0.6 4.6 1.9 295 7 284 165 -9.7 0 -9.5 -10 11/23/2005 21:30:00 4.2 0.9 6.5 1.9 4.3 0.9 6.8 2.3 4 0.9 6.5 1.9 290 7 279 165 -9.7 0 -9.5 -10 11/23/2005 21:40:00 6.5 1.2 9.5 4.2 6.6 1.2 9.5 4.2 5.9 1.3 9.5 3 288 8 292 165 -9.7 0 -9.7 -9.7 11/23/2005 21:50:00 7.8 1.1 9.9 4.9 7.8 1.1 10.3 4.9 6.9 1.3 10.3 3.8 291 6 284 165 -9.8 0 -9.7 -10 11/23/2005 22:00:00 8.8 1.1 11.1 6.1 8.8 1 11.1 5.7 7.4 1.2 10.7 4.2 292 5 295 165 -9.9 0 -9.7 -10.2 11/23/2005 22:10:00 9.5 1 12.2 5.7 9.5 1 12.2 6.1 7.7 1.2 11.1 5.3 294 6 300 165 -10 0 -9.7 -10.2 11/23/2005 22:20:00 9.5 1 13 6.8 9.5 1 13 6.5 7.7 1.2 10.7 4.9 293 6 298 165 -10 0 -9.7 -10.2 11/23/2005 22:30:00 9.3 1.5 12.6 5.7 9.3 1.5 12.2 5.7 7.7 1.4 11.1 4.2 293 5 292 165 -10 0 -9.7 -10.2 11/23/2005 22:40:00 8.2 1.3 12.2 5.3 8.3 1.3 12.2 5.3 7.1 1.3 11.1 3.8 293 7 298 165 -9.9 0 -9.7 -10.2 11/23/2005 22:50:00 7.7 0.8 9.9 5.3 7.6 0.8 9.5 4.9 6.2 0.9 8.4 3.8 303 8 302 165 -9.7 0 -9.7 -10 11/23/2005 23:00:00 6.2 1.2 9.1 3 6.1 1.2 9.5 3.4 5.6 1.1 8.4 3 316 12 326 165 -9.5 0 -9.3 -9.7 11/23/2005 23:10:00 5.5 1 8 3.4 5.5 1 8 3 5.3 0.9 8 3 328 11 301 165 -9.6 0 -9.3 -9.7 11/23/2005 23:20:00 6.4 0.9 9.1 4.2 6.3 0.9 9.1 3.8 5.4 1 8 3 313 8 316 165 -9.9 0.2 -9.7 -10.2 11/23/2005 23:30:00 7.5 1.1 10.3 4.6 7.4 1 10.3 4.6 6 1 9.1 3.4 309 8 301 165 -10.1 0 -10 -10.4 11/23/2005 23:40:00 6.1 0.7 8.4 4.2 6 0.7 8.8 4.2 5.8 0.8 8.4 3.4 324 10 324 165 -10.1 0 -10 -10.2 11/23/2005 23:50:00 8 1.5 12.2 5.3 7.9 1.5 12.2 5.3 7.6 1.3 11.8 4.2 333 8 339 165 -9.7 0.2 -9.3 -10.2 11/24/2005 00:00:00 8.5 1.2 11.8 5.3 8.2 1.3 12.2 4.6 8 1.3 11.8 4.9 340 9 351 165 -9.2 0 -9.1 -9.3 11/24/2005 00:10:00 9.7 1.1 13 6.5 9.5 1.2 13.3 6.1 9.1 1.2 13.3 6.1 340 7 351 165 -9.1 0 -8.9 -9.3 11/24/2005 00:20:00 8.8 1.3 11.5 5.3 8.5 1.4 11.8 5.7 8.5 1.4 11.8 5.7 335 12 339 165 -9.1 0 -8.9 -9.3 11/24/2005 00:30:00 7.7 1 10.7 4.9 7.7 1 10.7 5.3 6.4 1.3 9.5 3.4 311 12 304 165 -9.5 0.2 -9.1 -9.7 11/24/2005 00:40:00 9.3 1 12.2 6.8 9.2 1 12.2 6.8 8.3 1.1 11.1 5.3 312 6 312 165 -9.7 0 -9.7 -9.7 11/24/2005 00:50:00 10.6 0.7 12.6 8.4 10.5 0.7 12.2 8 9.8 0.8 11.5 7.2 315 7 321 165 -9.5 0.1 -9.3 -9.7 11/24/2005 01:00:00 11 0.6 12.6 8.8 11 0.6 12.6 8.8 9.3 1.1 11.8 6.5 308 3 312 165 -9.7 0 -9.7 -9.7 11/24/2005 01:10:00 10.5 0.6 11.8 8.8 10.5 0.7 11.8 8.8 8.2 1.1 11.1 6.1 306 3 307 165 -9.9 0 -9.7 -10 11/24/2005 01:20:00 9.3 0.6 11.1 8 9.3 0.6 10.7 8 7.5 1 9.9 5.3 307 3 313 165 -10 0 -9.7 -10.2 11/24/2005 01:30:00 9.5 0.6 11.1 7.6 9.5 0.6 10.7 7.6 7.5 1 9.5 4.9 307 3 305 165 -10 0 -9.7 -10.2 11/24/2005 01:40:00 9.8 0.4 11.1 8.8 9.8 0.4 11.1 8.4 6.8 0.6 8.8 5.3 304 2 308 165 -10 0 -9.7 -10.2 11/24/2005 01:50:00 10.4 0.6 11.8 8.8 10.3 0.6 11.5 8.4 7.5 0.8 9.9 5.7 304 3 305 165 -9.9 0 -9.7 -10.2 11/24/2005 02:00:00 10 0.6 11.8 8.4 9.9 0.6 11.8 8.4 7 0.7 9.1 5.3 303 3 304 165 -9.8 0.1 -9.7 -10 11/24/2005 02:10:00 9.4 0.9 11.5 7.2 9.4 0.8 11.8 7.2 7.2 1.3 11.1 4.9 306 5 292 165 -9.7 0 -9.5 -9.7 11/24/2005 02:20:00 9.4 1.2 12.6 6.8 9.4 1.2 13 6.8 8 1.2 11.5 5.3 309 5 304 165 -9.7 0 -9.5 -10 11/24/2005 02:30:00 9.7 1.3 12.6 6.8 9.6 1.3 12.6 6.8 8.4 1.5 12.2 4.9 310 6 300 165 -9.6 0.1 -9.3 -9.7 11/24/2005 02:40:00 9.5 1.3 13 6.5 9.4 1.3 13 6.5 8.5 1.5 13 5.3 313 8 308 165 -9.7 0 -9.5 -10 11/24/2005 02:50:00 8.5 1.4 12.2 4.6 8.5 1.3 11.8 5.3 7.7 1.5 11.8 3.8 316 9 320 165 -9.9 0 -9.7 -10.2 11/24/2005 03:00:00 7.3 1.1 10.7 5.3 7.3 1 10.3 5.3 6.5 1.1 9.9 4.2 316 9 307 165 -10.2 0.1 -10 -10.4 11/24/2005 03:10:00 7.3 1 9.9 5.3 7.2 1 9.9 5.3 6.1 1.2 9.9 3 311 10 319 165 -10.3 0 -10.2 -10.4 11/24/2005 03:20:00 8 1.3 11.5 4.6 7.9 1.3 11.5 4.2 6.7 1.2 10.3 3.4 309 11 305 165 -10.2 0 -10 -10.2 11/24/2005 03:30:00 8.3 1.1 11.5 5.7 8.2 1 11.5 5.7 7.1 1.2 10.3 4.9 307 8 298 165 -10.1 0 -10 -10.4 11/24/2005 03:40:00 8.9 1.2 12.2 5.7 8.8 1.2 12.2 5.7 7.8 1.1 11.1 4.9 310 9 303 165 -9.9 0 -9.7 -10.2 11/24/2005 03:50:00 9.9 1 13 7.2 9.7 1 12.6 6.8 8.9 1.1 11.8 6.1 312 8 322 165 -9.7 0 -9.7 -10 11/24/2005 04:00:00 10 1.2 13 6.5 9.9 1.2 12.6 6.8 9.1 1.3 12.6 5.3 313 8 323 165 -9.7 0 -9.7 -10 11/24/2005 04:10:00 10.1 1.3 14.1 6.8 10 1.3 14.1 6.8 9.2 1.7 13.3 2.6 319 8 319 165 -9.7 0.1 -9.7 -10.2 11/24/2005 04:20:00 9.8 1.3 13.3 7.2 9.7 1.3 13.7 7.2 8.7 1.5 14.1 3.8 313 9 321 165 -9.4 0 -9.1 -9.7 11/24/2005 04:30:00 10.5 1.5 15.3 6.1 10.4 1.5 15.3 6.8 8.8 1.6 12.6 3.4 307 8 307 165 -9.6 0 -9.3 -9.7 11/24/2005 04:40:00 13 1.2 17.2 9.9 12.9 1.2 16.8 9.5 11.2 1.5 15.3 8 308 5 312 165 -9.3 0 -9.1 -9.5 11/24/2005 04:50:00 14.5 1.2 17.6 11.1 14.4 1.2 17.6 11.1 12.2 1.6 16.1 8.4 308 5 303 165 -9.1 0 -9.1 -9.3 11/24/2005 05:00:00 13.7 1.1 16.8 11.5 13.7 1.1 16.8 11.1 11.7 1.7 15.6 8 309 6 307 165 -9.3 0 -9.1 -9.3 11/24/2005 05:10:00 14.9 1 17.9 12.2 14.8 1 17.6 12.6 13.7 1.3 16.8 9.5 311 4 308 165 -9.2 0 -9.1 -9.3 11/24/2005 05:20:00 13.2 0.9 15.3 9.9 13.1 0.9 15.3 9.9 12.7 1.2 15.6 8.8 312 5 320 165 -9.3 0 -9.1 -9.3 11/24/2005 05:30:00 13.6 0.9 16.1 11.5 13.5 0.9 16.4 11.1 12.5 1.2 16.1 9.5 311 4 316 165 -9.3 0 -9.1 -9.3 11/24/2005 05:40:00 12.3 1.2 16.4 9.9 12.2 1.3 16.4 9.5 11.4 1.3 15.3 8 312 6 308 165 -9.3 0 -9.1 -9.7 11/24/2005 05:50:00 11.5 1 14.1 8.8 11.4 1 14.1 8.4 10.2 1.3 13.7 6.1 310 6 310 165 -9.3 0 -9.1 -9.5 11/24/2005 06:00:00 11.9 1.2 14.9 8.8 11.8 1.2 14.9 9.1 10.8 1.2 14.1 7.6 311 5 310 165 -9.2 0 -9.1 -9.5 11/24/2005 06:10:00 11.6 1 14.1 8.8 11.5 1 13.7 8.4 10.1 1.1 13 6.5 310 6 302 165 -9.1 0 -8.9 -9.1 11/24/2005 06:20:00 11.5 0.9 14.1 8.8 11.3 1 14.1 8 11 1.1 14.5 7.2 316 6 318 165 -9.1 0 -8.9 -9.3 11/24/2005 06:30:00 12.7 1.3 16.1 9.5 12.6 1.3 15.6 9.1 11.7 1.3 14.5 8 312 5 310 165 -8.8 0.1 -8.5 -9.1 11/24/2005 06:40:00 10.5 0.9 13 8.8 10.4 0.9 13 8.4 10 1 12.2 7.2 315 5 306 165 -8.8 0 -8.5 -8.9 11/24/2005 06:50:00 9.3 1 11.8 6.5 9.2 1 11.8 6.5 8.7 1 11.5 5.3 313 6 314 165 -8.8 0 -8.7 -8.9 11/24/2005 07:00:00 9.6 1 12.6 6.8 9.5 1 13 6.8 8.3 1.2 11.8 4.9 307 7 300 165 -8.7 0 -8.5 -8.9 11/24/2005 07:10:00 9.4 1 13 7.2 9.3 1 13.3 6.8 7.8 1 11.8 5.3 305 8 316 165 -8.8 0 -8.5 -8.9 11/24/2005 07:20:00 9.4 0.9 11.8 7.2 9.4 0.9 12.2 7.2 7.4 1.1 11.8 5.3 301 9 301 165 -8.9 0 -8.9 -9.1 11/24/2005 07:30:00 10.9 1.2 14.1 7.6 10.8 1.2 14.1 7.6 9 1.5 13.7 6.1 304 8 300 165 -8.8 0 -8.5 -8.9 11/24/2005 07:40:00 9.9 1.2 13.3 6.5 9.9 1.2 13.3 6.5 8.1 1.2 11.1 5.3 302 8 298 165 -8.9 0 -8.7 -8.9 11/24/2005 07:50:00 10.8 1.3 14.9 7.6 10.8 1.3 14.5 7.2 9.3 1.8 13.7 5.3 305 9 302 165 -8.8 0 -8.7 -8.9 11/24/2005 08:00:00 11.7 1.1 14.9 9.1 11.7 1.1 15.3 9.1 9.6 1.6 13.7 5.3 303 8 300 165 -8.8 0 -8.7 -8.9 11/24/2005 08:10:00 10.9 1.3 14.5 7.6 10.8 1.3 14.5 7.2 8.8 1.2 12.6 6.1 303 8 300 165 -8.7 0 -8.5 -8.9 11/24/2005 08:20:00 11.5 1.1 14.1 7.6 11.5 1.1 14.1 7.6 10 1.3 13.3 6.8 309 8 315 165 -8.7 0 -8.5 -8.9 11/24/2005 08:30:00 11.3 1.9 15.6 5.3 11.2 1.9 15.6 5.7 9.5 1.9 14.9 6.5 307 8 311 165 -8.7 0 -8.5 -8.9 11/24/2005 08:40:00 11 1.5 14.5 7.6 10.9 1.5 14.5 7.6 9.7 1.8 14.5 6.1 309 6 308 165 -8.8 0 -8.7 -8.9 11/24/2005 08:50:00 12.3 1.7 16.1 7.6 12.2 1.7 16.4 8 10.4 1.7 14.5 6.1 307 9 304 165 -8.9 0 -8.7 -8.9 11/24/2005 09:00:00 11.7 1.3 15.6 8.8 11.7 1.3 15.3 8.8 9.8 1.5 14.1 6.5 306 8 300 165 -9 0.1 -8.9 -9.1 11/24/2005 09:10:00 11.3 1 13.7 8 11.2 1 14.1 8 9.7 1.6 14.1 6.5 305 9 322 165 -9.1 0 -8.9 -9.1 11/24/2005 09:20:00 12.6 1.9 16.8 8 12.5 1.9 16.8 8 10.5 2.3 16.4 6.1 305 8 301 165 -9 0 -8.7 -9.1 11/24/2005 09:30:00 12.1 1.7 16.1 7.2 12 1.7 16.1 7.2 10.4 2 15.3 6.1 306 8 310 165 -8.9 0 -8.7 -8.9 11/24/2005 09:40:00 13.2 1.2 16.8 9.9 13.1 1.2 16.4 9.9 10.9 1.7 16.1 6.8 307 6 308 165 -8.9 0 -8.7 -8.9 11/24/2005 09:50:00 12.2 1.7 16.1 7.6 12.1 1.7 15.6 7.6 10.6 1.6 14.9 5.7 309 8 307 165 -8.9 0 -8.7 -8.9 11/24/2005 10:00:00 13 1.2 16.4 9.9 12.9 1.2 16.1 9.9 10.9 1.6 14.9 6.8 306 6 310 165 -9 0.1 -8.9 -9.1 11/24/2005 10:10:00 12.1 1.5 15.6 8 12 1.5 15.6 8 10.7 1.7 14.9 6.5 309 6 308 165 -9.1 0 -8.9 -9.1 11/24/2005 10:20:00 12.8 1.4 17.2 9.1 12.7 1.4 17.2 8.8 11.4 1.5 15.3 8 308 8 303 165 -8.9 0 -8.7 -9.1 11/24/2005 10:30:00 12.6 1.1 15.3 9.9 12.5 1.2 15.3 9.5 11.1 1.3 15.3 6.8 307 6 305 165 -9 0 -8.9 -9.1 11/24/2005 10:40:00 12.2 1 15.3 9.1 12.1 1 15.3 8.8 10.3 1.2 14.5 6.8 307 5 307 165 -9 0.1 -8.7 -9.1 11/24/2005 10:50:00 11.8 1.5 16.1 8.4 11.7 1.5 15.6 8.4 11.2 1.7 15.3 7.2 317 7 316 165 -8.5 0.1 -8.3 -8.9 11/24/2005 11:00:00 13 1.3 16.1 9.1 12.9 1.2 16.4 9.5 12.4 1.3 15.3 9.5 319 7 318 165 -8.4 0 -8.3 -8.7 11/24/2005 11:10:00 12.4 1.2 14.5 7.2 12.3 1.2 14.5 7.2 11.8 1.2 14.5 7.2 317 6 314 165 -8.4 0 -8.3 -8.5 11/24/2005 11:20:00 11 1.2 14.5 8 10.9 1.2 14.5 8 10.4 1.2 13 7.2 315 6 312 165 -8.3 0 -8.1 -8.5 11/24/2005 11:30:00 9.5 0.9 11.8 6.5 9.4 0.9 11.8 6.5 8.9 1.2 11.8 5.7 315 7 317 165 -8.3 0 -8.1 -8.5 11/24/2005 11:40:00 9.4 1 11.8 6.5 9.3 1 11.8 6.5 8.4 1.2 11.1 5.3 311 8 311 165 -8.4 0.1 -8.3 -8.5 11/24/2005 11:50:00 8.7 1.5 13 5.7 8.6 1.5 13 5.7 7.2 1.6 13 3.8 303 8 283 165 -8.7 0 -8.5 -8.9 11/24/2005 12:00:00 10.4 1.2 13.3 6.8 10.3 1.2 13.3 6.5 8.8 1.3 11.8 4.9 307 6 306 165 -8.9 0 -8.7 -8.9 11/24/2005 12:10:00 6.1 1.5 9.1 2.3 6.1 1.5 9.1 2.3 5 1.3 8.4 2.3 295 13 306 165 -8.7 0.1 -8.5 -8.9 11/24/2005 12:20:00 5 1 7.2 2.6 5.6 0.7 7.2 3.4 5.2 0.7 6.8 3.4 272 8 281 165 -8.7 0 -8.5 -8.9 11/24/2005 12:30:00 5.8 1.1 8.8 3.4 6.1 1.1 9.1 3.8 5.7 1.1 8.8 3 277 10 286 165 -8.7 0 -8.5 -8.9 11/24/2005 12:40:00 7.3 1.3 11.1 4.6 7.5 1.2 11.1 4.9 7 1.2 11.1 4.6 281 8 289 165 -8.5 0 -8.5 -8.5 11/24/2005 12:50:00 9.6 1 12.2 6.5 9.7 1 11.8 6.8 8.7 1.4 11.5 4.6 287 7 285 165 -8.5 0 -8.3 -8.5 11/24/2005 13:00:00 9.2 1 12.2 6.5 9.3 1.1 12.6 6.5 8.3 1.5 12.2 4.9 288 9 281 165 -8.6 0 -8.3 -8.7 11/24/2005 13:10:00 12.1 1.2 14.9 7.6 12.2 1.2 14.9 7.6 10.4 1.7 14.1 5.7 290 6 283 165 -8.4 0 -8.1 -8.5 11/24/2005 13:20:00 13.4 1 16.4 11.1 13.4 1.1 16.4 10.7 12.4 1.9 16.8 7.6 285 6 287 165 -8.7 0 -8.5 -8.9 11/24/2005 13:30:00 13.4 1.2 16.1 9.5 13.5 1.2 16.1 9.1 11.8 2 16.8 7.2 289 6 282 165 -8.8 0 -8.7 -8.9 11/24/2005 13:40:00 11.5 1.6 14.5 6.8 11.5 1.6 14.9 7.6 9.6 1.9 14.5 4.9 291 8 286 165 -8.9 0 -8.9 -9.1 11/24/2005 13:50:00 12.1 1.5 14.9 7.6 12.1 1.5 14.9 7.2 10.1 1.5 13.7 6.1 291 6 292 165 -9.1 0.1 -8.9 -9.3 11/24/2005 14:00:00 12.5 1.5 16.4 8.8 12.5 1.6 16.4 8.8 10.3 1.8 14.5 6.8 294 8 285 165 -9.3 0 -9.1 -9.3 11/24/2005 14:10:00 11.1 1.5 14.5 7.2 11.1 1.5 14.1 7.6 9.3 1.7 14.5 6.1 291 7 283 165 -9.5 0 -9.3 -9.7 11/24/2005 14:20:00 10.7 1.3 13.3 6.1 10.7 1.3 13.3 6.1 8.8 1.5 13 5.3 294 7 287 165 -9.6 0 -9.3 -9.7 11/24/2005 14:30:00 11.7 1.1 14.5 8 11.7 1.1 14.5 8 9.4 1.6 14.5 6.1 294 6 287 165 -9.7 0 -9.5 -9.7 11/24/2005 14:40:00 13.1 1 15.6 9.9 13.1 1 15.3 10.3 10.4 1.6 14.5 7.2 292 6 292 165 -9.9 0 -9.7 -10 11/24/2005 14:50:00 14 1.5 17.6 9.1 14 1.5 17.6 9.5 11.5 2 16.8 7.2 292 6 290 165 -10 0 -9.7 -10.2 11/24/2005 15:00:00 15.7 1.8 18.7 11.1 15.8 1.9 19.1 10.7 13.5 2.3 19.1 7.6 289 5 287 165 -10.1 0.1 -10 -10.4 11/24/2005 15:10:00 16.4 1.2 19.1 12.6 16.5 1.3 19.1 12.6 15.1 2.2 19.1 9.1 287 4 286 165 -10.4 0 -10.2 -10.6 11/24/2005 15:20:00 14.9 1.1 16.8 11.5 15 1.1 17.2 11.1 13 1.7 17.2 8.4 288 4 285 165 -10.4 0 -10.2 -10.6 11/24/2005 15:30:00 12.7 1.2 15.6 9.1 12.7 1.2 15.6 9.1 11.6 1.5 16.1 7.6 286 5 286 165 -10.5 0 -10.4 -10.6 11/24/2005 15:40:00 11.9 1.1 14.9 8 12 1.2 15.3 8.4 11 1.5 14.5 5.7 284 6 285 165 -10.6 0 -10.4 -10.8 11/24/2005 15:50:00 12 1.2 14.5 8 12 1.2 14.5 7.6 10.8 1.6 14.5 5.7 285 6 281 165 -10.8 0 -10.6 -11 11/24/2005 16:00:00 10.9 1.4 13.7 6.5 10.9 1.4 13.7 6.8 9.6 1.8 13.3 4.9 286 7 281 165 -10.8 0 -10.6 -11 11/24/2005 16:10:00 11.1 1.7 14.9 6.8 11.1 1.7 15.6 6.8 9.8 1.9 13.7 5.3 286 9 283 165 -10.9 0 -10.6 -11 11/24/2005 16:20:00 10.8 2 14.9 5.7 10.7 2 15.3 5.7 9.3 2.2 14.5 4.9 292 9 282 165 -11 0 -11 -11.2 11/24/2005 16:30:00 8.7 1.7 13.3 4.2 8.7 1.7 13.3 4.6 7.3 1.7 12.6 3.8 293 11 284 165 -11.2 0 -11 -11.4 11/24/2005 16:40:00 9.6 2.2 14.5 4.6 9.7 2.2 14.9 4.6 8.7 2.4 14.1 3.8 288 11 285 165 -11.2 0 -11 -11.4 11/24/2005 16:50:00 12.1 1.9 16.1 6.5 12.1 1.9 16.1 6.8 10.8 2 16.8 5.7 287 7 284 165 -11.2 0 -11 -11.4 11/24/2005 17:00:00 10.9 1.8 15.3 5.3 10.9 1.8 15.3 5.7 9.4 2.2 15.3 4.9 289 10 296 165 -11 0 -10.8 -11.2 11/24/2005 17:10:00 13.2 1.4 16.1 9.1 13.4 1.3 16.4 9.5 12.9 1.7 16.8 8 282 5 279 165 -11.3 0.1 -11 -11.4 11/24/2005 17:20:00 12.2 1.6 15.3 8 12.4 1.5 15.6 8.8 11.7 1.9 16.1 6.8 282 8 284 165 -11.5 0 -11.4 -11.8 11/24/2005 17:30:00 10.7 1.9 13.7 5.7 10.7 1.8 14.1 5.7 9.4 2 14.1 3.4 287 8 278 165 -11.6 0 -11.4 -11.8 11/24/2005 17:40:00 8.4 1.8 12.2 3.4 8.7 1.7 12.6 4.6 7.8 1.7 11.8 3 280 10 279 165 -11.6 0 -11.6 -11.8 11/24/2005 17:50:00 9.5 1.5 12.6 4.9 9.5 1.5 12.6 5.7 8.5 1.7 12.2 4.2 286 9 280 165 -11.6 0 -11.4 -11.8 11/24/2005 18:00:00 7.9 1.8 13.3 4.2 8 1.7 13 4.6 6.7 2 13.3 3.4 295 13 284 165 -11.8 0.1 -11.6 -11.8 11/24/2005 18:10:00 8.8 2.5 14.5 3.4 8.8 2.5 14.5 3.4 7.7 2.6 13.7 2.3 287 10 278 165 -11.9 0 -11.8 -12.2 11/24/2005 18:20:00 12 1.6 16.1 7.6 12 1.6 16.4 7.6 10.4 1.9 15.3 6.1 288 8 292 165 -11.8 0 -11.6 -11.8 11/24/2005 18:30:00 11.8 1.8 15.6 6.8 11.7 1.8 16.1 6.8 10 2 15.6 6.1 290 7 287 165 -11.7 0 -11.6 -11.8 11/24/2005 18:40:00 13.7 1.7 16.8 8.8 13.7 1.7 16.8 8.4 12.2 2.4 17.9 6.8 287 6 286 165 -11.6 0 -11.4 -11.8 11/24/2005 18:50:00 14.2 1.3 17.6 10.3 14.2 1.3 17.6 10.3 12 2.2 17.2 7.2 290 7 303 165 -11.5 0 -11.4 -11.8 11/24/2005 19:00:00 15 1.3 17.9 11.1 15 1.4 17.6 11.1 12.7 1.9 17.6 8.4 290 6 290 165 -11.3 0 -11.2 -11.4 11/24/2005 19:10:00 10.6 1.3 14.9 6.8 10.5 1.3 14.9 6.5 9 1.3 13 5.3 289 6 279 165 -11.3 0 -11 -11.4 11/24/2005 19:20:00 8.7 1.5 13.3 4.6 8.8 1.5 13.7 5.7 7.9 1.6 14.1 4.6 284 8 282 165 -11.3 0 -11 -11.4 11/24/2005 19:30:00 8.1 1.2 11.5 5.3 8.1 1.2 11.8 5.7 7.2 1.3 11.5 3.8 286 8 293 165 -11.3 0 -11 -11.4 11/24/2005 19:40:00 7.8 1.7 11.8 4.6 7.7 1.7 11.5 4.2 6.5 1.5 11.8 3.4 294 9 297 165 -11.2 0.1 -11 -11.4 11/24/2005 19:50:00 8.5 1.7 11.8 3.4 8.5 1.6 11.5 3.4 7.4 1.7 11.1 2.6 289 9 292 165 -11.4 0.1 -11.2 -11.6 11/24/2005 20:00:00 9.5 1.3 13.7 6.5 9.5 1.3 13.7 6.5 7.9 1.5 12.6 4.9 291 8 302 165 -11.4 0 -11.4 -11.6 11/24/2005 20:10:00 9.8 1.1 12.6 7.2 9.7 1.1 12.2 7.2 8.2 1.3 13.3 5.3 291 8 284 165 -11.5 0 -11.4 -11.8 11/24/2005 20:20:00 14.2 1.9 19.5 9.5 14.3 1.9 19.1 9.5 12.9 2.4 18.3 7.2 286 7 284 165 -11.6 0 -11.4 -11.8 11/24/2005 20:30:00 13.2 1.5 17.6 9.5 13.2 1.5 17.6 9.1 11.2 1.9 15.6 6.8 289 7 296 165 -11.6 0 -11.4 -11.8 11/24/2005 20:40:00 11 1.6 14.1 6.1 11 1.6 14.5 6.1 9.1 1.6 13.3 5.7 297 9 296 165 -11.8 0 -11.6 -11.8 11/24/2005 20:50:00 11.3 1.7 15.3 7.2 11.3 1.7 14.9 6.8 9.4 2 14.5 5.3 293 8 286 165 -12 0 -11.8 -12.2 11/24/2005 21:00:00 10.9 1.5 14.9 7.2 10.9 1.6 14.9 7.2 8.8 1.7 13.3 5.3 296 8 299 165 -12 0 -11.8 -12.2 11/24/2005 21:10:00 12.5 1.7 17.2 7.2 12.5 1.8 16.8 7.2 10 1.7 15.3 6.5 294 7 298 165 -12.1 0 -11.8 -12.2 11/24/2005 21:20:00 14 1.6 17.2 9.9 14 1.6 17.6 10.3 11.5 1.8 16.4 7.6 298 8 287 165 -11.9 0 -11.8 -12.2 11/24/2005 21:30:00 13.4 1.4 16.4 9.9 13.3 1.5 16.4 9.5 10.4 1.5 15.6 7.2 295 7 301 165 -12.1 0 -12 -12.2 11/24/2005 21:40:00 13.4 1.4 17.9 10.7 13.4 1.5 17.9 10.3 11.2 1.9 16.1 7.2 292 8 295 165 -12.1 0 -11.8 -12.2 11/24/2005 21:50:00 14.9 1.3 17.9 10.3 14.9 1.3 17.9 9.9 13.2 1.9 19.1 8 288 4 282 165 -11.9 0 -11.8 -12.2 11/24/2005 22:00:00 14.3 1.5 17.9 11.1 14.3 1.5 18.3 10.7 12.4 1.9 17.6 7.2 289 6 290 165 -12 0 -11.8 -12.2 11/24/2005 22:10:00 14.2 1.5 17.9 11.1 14.2 1.5 17.9 11.1 11.8 2.1 17.6 7.6 291 6 291 165 -12 0 -11.8 -12.2 11/24/2005 22:20:00 13.9 1.2 17.2 8.8 13.9 1.3 17.2 8.4 11.6 1.7 16.1 7.6 291 6 287 165 -11.9 0 -11.8 -12 11/24/2005 22:30:00 13.8 1.5 17.2 9.1 13.8 1.5 17.6 9.5 11 1.7 16.1 6.8 295 6 293 165 -11.9 0 -11.8 -12 11/24/2005 22:40:00 14.5 1.7 17.6 9.9 14.4 1.7 17.6 9.5 11.2 1.4 15.3 7.2 300 7 302 165 -11.9 0 -11.8 -12.2 11/24/2005 22:50:00 14.1 1.8 18.3 9.1 14.1 1.8 18.3 9.5 11 1.7 16.4 7.2 299 7 288 165 -11.9 0 -11.8 -12 11/24/2005 23:00:00 15 1.3 18.3 11.5 15 1.3 18.3 11.1 11.3 1.5 16.4 8.8 298 6 287 165 -11.9 0 -11.8 -12.2 11/24/2005 23:10:00 13.6 1.7 17.9 10.3 13.6 1.7 17.9 10.3 10.7 1.7 15.3 7.2 301 7 291 165 -11.9 0 -11.8 -12 11/24/2005 23:20:00 14.6 1.5 17.6 9.1 14.6 1.5 17.6 9.1 10.9 1.6 15.6 6.5 300 6 298 165 -11.9 0 -11.8 -12 11/24/2005 23:30:00 14.8 1.4 17.9 9.5 14.8 1.4 17.9 9.1 11.4 1.7 17.6 7.6 296 6 300 165 -11.9 0 -11.8 -12 11/24/2005 23:40:00 13.3 1.4 16.8 9.9 13.3 1.4 17.2 9.9 10.4 1.7 16.4 6.8 299 8 301 165 -11.9 0 -11.8 -12.2 11/24/2005 23:50:00 14.2 1.6 19.1 10.7 14.2 1.6 19.1 9.9 10.9 1.7 16.1 7.6 299 7 291 165 -11.8 0 -11.8 -12 11/25/2005 00:00:00 12.3 1.3 15.3 8.4 12.3 1.3 15.6 8.4 9.9 1.6 14.9 6.5 297 8 291 165 -11.9 0 -11.6 -11.8 11/25/2005 00:10:00 12 1.2 14.9 8.8 12 1.2 14.9 8.8 9.5 1.7 13.7 6.1 296 8 285 165 -11.8 0 -11.6 -11.8 11/25/2005 00:20:00 9.8 1.4 13.3 5.7 9.7 1.4 13.3 6.5 8 1.7 14.5 4.2 301 9 288 165 -11.9 0 -11.8 -11.8 11/25/2005 00:30:00 9.5 1.3 13 6.1 9.4 1.3 12.6 6.5 7.5 1.3 11.5 4.6 297 8 293 165 -11.9 0 -11.8 -12 11/25/2005 00:40:00 9.2 1.2 11.8 5.7 9.1 1.2 11.8 5.7 7.6 1.3 11.5 4.6 293 8 302 165 -11.9 0 -11.8 -12 11/25/2005 00:50:00 7.3 1.4 11.8 4.2 7.3 1.4 11.8 4.2 6.2 1.7 11.8 3.4 293 11 280 165 -11.9 0 -11.8 -12 11/25/2005 01:00:00 7.6 1.6 11.5 4.6 7.6 1.5 11.5 4.6 6.6 1.7 10.7 3 290 8 289 165 -11.8 0 -11.6 -12 11/25/2005 01:10:00 7.3 0.8 9.5 5.3 7.3 0.8 9.9 5.3 6.8 1 9.9 4.2 284 6 270 165 -11.9 0 -11.8 -12 11/25/2005 01:20:00 7.9 0.8 9.9 5.7 7.9 0.8 9.9 6.1 7 1.1 9.9 4.6 289 5 289 165 -11.9 0 -11.8 -12 11/25/2005 01:30:00 7.5 0.8 10.3 5.3 7.6 0.8 9.9 5.3 6.6 1 8.8 4.2 287 9 292 165 -11.8 0 -11.8 -12 11/25/2005 01:40:00 5.8 1.1 8 2.6 6.3 1 8.8 4.2 6 1 8.4 3 272 9 269 165 -11.9 0 -11.8 -11.8 11/25/2005 01:50:00 5.6 1 8.4 3 5.9 1 8.4 3.4 5.5 1.2 8.4 3 279 11 285 165 -11.8 0 -11.6 -12 11/25/2005 02:00:00 3.7 0.8 5.7 1.1 3.9 0.7 5.7 1.9 3.8 0.8 6.1 1.5 261 18 281 165 -11.9 0 -11.8 -12 11/25/2005 02:10:00 2.7 1 4.9 0.4 2.8 1 5.3 0.4 2.5 1 4.9 0.4 258 26 286 165 -12 0 -11.8 -12.2 11/25/2005 02:20:00 5.2 1.2 8 2.6 5.6 1.1 8 3.4 5.3 1.1 8 2.6 272 11 291 165 -12 0 -11.8 -12.2 11/25/2005 02:30:00 5.7 1.8 9.9 1.9 6.1 1.5 9.9 2.6 5.6 1.4 9.9 2.3 274 13 288 165 -12.1 0.1 -11.8 -12.2 11/25/2005 02:40:00 5.9 1.8 9.5 2.6 6.2 1.5 9.5 3 5.7 1.3 9.1 2.6 277 13 285 165 -11.9 0 -11.8 -12 11/25/2005 02:50:00 2.7 1.2 6.1 0.4 3.1 1.3 6.1 0.4 2.9 1.3 6.1 0.4 250 23 241 165 -12.1 0 -11.8 -12.2 11/25/2005 03:00:00 2.1 0.6 3.4 0.4 2.1 0.5 3.4 0.7 2.1 0.5 3.4 0.4 224 18 202 165 -12.3 0 -12 -12.4 11/25/2005 03:10:00 3.5 1 6.1 1.1 3.9 1 6.1 1.1 3.5 1 6.1 1.5 260 20 261 165 -12 0 -11.8 -12.2 11/25/2005 03:20:00 3 0.8 5.3 1.1 3.5 0.7 4.9 1.1 3.1 0.8 4.6 1.1 261 13 277 165 -12.2 0 -12 -12.2 11/25/2005 03:30:00 2.6 1 5.7 0.4 2.8 1 5.7 0.4 2.6 0.8 4.9 0.7 239 23 310 165 -12.3 0 -12.2 -12.4 11/25/2005 03:40:00 1.7 0.9 3.8 0.4 1.9 1 4.2 0.4 1.6 0.8 3 0.4 245 17 277 165 -12.2 0 -12 -12.4 11/25/2005 03:50:00 3.2 0.8 6.1 1.5 3.9 0.8 6.5 2.3 3.6 0.7 6.1 2.3 260 10 263 165 -12.2 0.1 -12 -12.4 11/25/2005 04:00:00 3.4 0.9 5.7 1.5 4.1 0.7 6.1 2.3 3.6 0.7 5.3 1.9 266 8 276 165 -12.3 0 -12.2 -12.4 11/25/2005 04:10:00 5 0.4 6.1 3.4 5.1 0.4 6.1 3.8 4.8 0.5 6.1 3 280 6 273 165 -12.1 0 -12 -12.4 11/25/2005 04:20:00 5.4 0.5 6.8 4.2 5.5 0.5 7.2 4.2 5.1 0.6 6.8 2.6 282 6 286 165 -12.2 0 -12 -12.4 11/25/2005 04:30:00 5.5 0.9 6.8 3 5.6 0.7 7.2 3.8 5.1 0.7 6.8 3.4 280 6 280 165 -12.3 0 -12.2 -12.4 11/25/2005 04:40:00 6.3 0.4 7.2 5.3 6.4 0.4 7.6 5.3 5.5 0.8 7.2 3.4 286 4 281 165 -12.4 0.1 -12.2 -12.6 11/25/2005 04:50:00 6.9 0.8 8.8 4.2 7.1 0.7 8.8 4.9 6.6 0.9 8.8 4.6 278 6 277 165 -12.3 0 -12.2 -12.6 11/25/2005 05:00:00 7.8 1.2 10.7 4.9 7.9 1.2 10.7 4.9 7.2 1.2 10.7 4.2 282 6 282 165 -12.1 0 -11.8 -12.2 11/25/2005 05:10:00 8.6 1 11.1 5.7 8.5 1 11.1 5.7 7 1.2 10.3 4.6 295 8 304 165 -11.9 0 -11.8 -12 11/25/2005 05:20:00 8.3 1 10.3 6.1 8.2 1 10.7 6.1 6.5 1 9.9 3.8 298 7 297 165 -11.9 0 -11.8 -12 11/25/2005 05:30:00 9.6 1.1 12.2 6.1 9.5 1.1 11.8 6.5 7.6 1.1 10.3 5.3 298 7 293 165 -11.8 0 -11.6 -11.8 11/25/2005 05:40:00 8 1.4 11.5 3.8 7.9 1.3 11.5 3.4 6.4 1.5 10.3 3 293 10 302 165 -11.8 0 -11.6 -12 11/25/2005 05:50:00 7.8 1.5 11.1 3.8 8.1 1.3 11.1 4.2 7.2 1.5 10.3 4.2 278 9 297 165 -11.8 0 -11.6 -12 11/25/2005 06:00:00 6.3 1.6 10.3 2.6 7 1.4 10.3 3.8 6.5 1.4 10.3 3.4 270 11 279 165 -11.7 0 -11.6 -11.8 11/25/2005 06:10:00 7.2 2.7 11.8 0.7 7.8 2.5 12.2 1.5 7.3 2.4 11.8 2.3 272 12 281 165 -11.7 0 -11.6 -11.8 11/25/2005 06:20:00 8 1.5 11.8 4.2 8.6 1.3 11.8 5.7 8 1.3 11.8 4.9 275 8 275 165 -11.7 0 -11.6 -11.8 11/25/2005 06:30:00 8.4 1.2 11.5 4.9 8.6 1.1 11.1 5.3 8.1 1.3 11.1 4.6 283 9 285 165 -11.6 0 -11.4 -11.8 11/25/2005 06:40:00 8.5 1.1 11.5 5.7 8.6 1.1 11.5 6.1 7.8 1.2 10.7 5.3 284 8 287 165 -11.5 0 -11.4 -11.6 11/25/2005 06:50:00 8.9 1.7 12.2 4.6 9 1.7 13.3 5.7 8.3 2 13.7 3.8 285 8 283 165 -11.6 0 -11.4 -11.8 11/25/2005 07:00:00 9.2 1 11.5 6.8 9.3 1 11.8 6.8 8.7 1.3 11.8 5.7 285 8 273 165 -11.6 0 -11.4 -11.8 11/25/2005 07:10:00 7.5 1.2 10.7 4.6 7.7 1.1 11.1 4.9 7.2 1.3 10.3 3.8 282 9 277 165 -11.8 0 -11.6 -11.8 11/25/2005 07:20:00 9.9 1.3 13.7 6.5 9.8 1.3 13.7 6.1 8.7 1.5 12.6 4.9 288 7 298 165 -11.6 0 -11.4 -12 11/25/2005 07:30:00 9.5 1.5 13.3 6.1 9.4 1.5 13.3 6.5 8.2 1.6 13.7 4.6 294 12 290 165 -11.6 0 -11.4 -11.6 11/25/2005 07:40:00 10.5 1.7 16.1 6.5 10.4 1.7 16.1 6.5 8.5 1.7 14.5 4.9 294 9 300 165 -11.6 0 -11.4 -11.8 11/25/2005 07:50:00 11.2 2.4 16.4 5.3 11.2 2.4 16.4 5.7 9.1 2.2 13.7 3.8 296 9 297 165 -11.8 0.1 -11.4 -12 11/25/2005 08:00:00 14.5 1.7 18.3 11.1 14.4 1.7 18.3 11.1 11.5 1.8 16.1 7.2 296 6 299 165 -11.9 0 -11.8 -12 11/25/2005 08:10:00 11.8 1.5 16.4 8.4 11.8 1.5 16.4 8.8 9.3 1.4 13 6.5 301 8 306 165 -12.1 0 -11.8 -12.4 11/25/2005 08:20:00 9.8 2.5 14.9 3.8 9.8 2.5 14.9 3.8 8.1 2.1 13.3 2.6 301 11 294 165 -12.3 0.1 -12.2 -12.6 11/25/2005 08:30:00 8.2 1.6 13 3.4 8.2 1.5 12.6 3.4 6.4 1.5 9.9 2.3 305 14 301 165 -12.7 0 -12.6 -12.8 11/25/2005 08:40:00 7.7 1.5 11.5 3.4 7.7 1.5 10.7 3.4 6.4 1.5 9.9 2.6 309 10 313 165 -12.7 0 -12.6 -12.8 11/25/2005 08:50:00 10.2 1.3 13 5.3 10.1 1.3 13 5.3 9.1 1.4 12.6 5.7 312 7 314 165 -12.7 0 -12.6 -13 11/25/2005 09:00:00 10.5 1.1 13 7.2 10.5 1.1 13.3 7.6 9.7 1.1 12.6 6.8 317 8 310 165 -12.7 0 -12.6 -13 11/25/2005 09:10:00 11 1.1 13.7 8 10.9 1.2 13.3 7.6 10.4 1.1 13 7.6 317 7 311 165 -12.8 0 -12.6 -13 11/25/2005 09:20:00 11.3 1.3 14.9 8 11.2 1.2 14.9 8.4 10.4 1.3 13.7 5.7 314 6 310 165 -12.8 0 -12.6 -13 11/25/2005 09:30:00 9.9 1.2 12.6 5.7 9.8 1.2 12.6 5.7 8.7 1.3 11.8 5.3 311 6 310 165 -12.7 0 -12.6 -13 11/25/2005 09:40:00 9.1 1.3 12.2 6.1 9 1.3 12.6 6.5 8.3 1.3 12.2 5.7 314 9 315 165 -12.5 0 -12.4 -12.6 11/25/2005 09:50:00 8.7 1.3 12.2 5.3 8.5 1.3 12.2 5.3 8.1 1.3 12.2 5.3 316 9 329 165 -12.4 0 -12.2 -12.6 11/25/2005 10:00:00 9.1 0.9 11.1 6.5 9 0.9 11.1 6.5 8.7 0.9 11.1 6.1 317 7 307 165 -12.2 0 -12 -12.4 11/25/2005 10:10:00 9.4 0.8 12.2 7.2 9.3 0.8 11.8 6.8 8.8 1 11.8 6.1 312 5 313 165 -12.3 0 -12.2 -12.4 11/25/2005 10:20:00 9.8 0.8 11.8 7.6 9.7 0.8 11.8 7.2 9 1 11.5 6.1 312 6 310 165 -12.3 0 -12.2 -12.4 11/25/2005 10:30:00 9.4 0.7 11.1 7.2 9.3 0.7 11.1 7.2 8.8 1.1 11.1 5.3 313 7 315 165 -12.1 0.1 -11.8 -12.2 11/25/2005 10:40:00 9.6 1 12.6 7.2 9.5 1 12.6 7.6 9.3 1.1 12.2 6.1 316 8 320 165 -11.9 0 -11.8 -12 11/25/2005 10:50:00 10.7 1.1 13 7.6 10.7 1.1 13 7.2 10.2 1 13 6.8 311 6 312 165 -11.9 0 -11.8 -12 11/25/2005 11:00:00 13 1.7 16.8 9.5 13 1.8 16.8 9.5 12.3 1.6 16.1 9.1 314 6 307 165 -12 0 -11.8 -12 11/25/2005 11:10:00 14 1.5 19.1 9.5 13.9 1.5 18.7 9.9 13.2 1.6 18.7 8 313 6 309 165 -12 0 -11.8 -12 11/25/2005 11:20:00 14.2 1.5 17.2 9.5 14.1 1.4 17.2 9.9 13.2 1.7 17.2 9.5 315 9 322 165 -11.9 0 -11.8 -12 11/25/2005 11:30:00 13.2 1.7 16.8 9.1 13.1 1.7 16.8 8.8 12.4 1.7 17.2 8 313 7 316 165 -11.8 0 -11.6 -11.8 11/25/2005 11:40:00 14.7 1.6 18.7 10.3 14.6 1.5 18.7 10.3 13.7 1.8 18.7 8 314 8 309 165 -11.9 0 -11.8 -11.8 11/25/2005 11:50:00 13.8 1.7 17.9 9.1 13.7 1.7 17.9 9.1 13.1 1.8 18.7 8 320 9 316 165 -11.5 0.2 -11.2 -11.8 11/25/2005 12:00:00 15.2 1.7 19.5 9.9 15.1 1.7 20.6 9.5 14.3 1.7 20.2 9.5 317 10 321 165 -11.4 0 -11.2 -11.4 11/25/2005 12:10:00 13.3 1.7 17.2 9.1 13.3 1.7 17.2 8.8 12.4 1.9 19.5 7.2 319 10 316 165 -11.3 0 -11 -11.4 11/25/2005 12:20:00 12.9 1.5 16.8 9.1 12.8 1.5 16.8 9.1 11.9 1.5 16.1 8 317 9 313 165 -11.2 0 -11 -11.4 11/25/2005 12:30:00 12.3 1.5 17.2 8.4 12.2 1.5 17.6 8.4 11.3 1.6 16.4 7.2 313 9 298 165 -11.2 0 -11 -11.4 11/25/2005 12:40:00 12 1.5 16.8 7.6 11.9 1.5 17.2 7.6 10.9 1.7 14.5 6.8 312 10 304 165 -11.1 0 -11 -11.2 11/25/2005 12:50:00 8.6 1.3 12.6 5.3 8.5 1.4 12.6 4.2 8 1.4 12.2 4.6 319 16 333 165 -10.7 0 -10.4 -11 11/25/2005 13:00:00 8.6 1.3 13.7 5.7 8.6 1.3 13.3 5.3 8 1.2 11.8 4.6 317 13 305 165 -10.7 0.1 -10.4 -11 11/25/2005 13:10:00 8.2 1.5 12.2 3.4 7.8 1.7 12.6 3.4 8 1.5 12.6 4.6 337 14 328 165 -10.9 0 -10.6 -11 11/25/2005 13:20:00 9.2 2 15.3 4.6 9.2 2 14.5 4.6 8.5 1.8 14.5 4.6 319 12 308 165 -10.9 0.1 -10.6 -11.2 11/25/2005 13:30:00 7.8 1.4 11.1 4.6 7.7 1.4 10.7 4.2 7.4 1.1 10.7 4.6 325 15 321 165 -11.2 0.2 -11 -11.6 11/25/2005 13:40:00 6.9 1.3 11.5 3.4 6.9 1.3 11.1 3.4 6.6 1.2 10.3 4.2 322 12 310 165 -11.6 0 -11.4 -11.8 11/25/2005 13:50:00 8.4 1.3 12.2 5.3 8.3 1.2 11.8 4.9 7.7 1.1 10.7 5.3 315 13 298 165 -11.5 0 -11.4 -11.6 11/25/2005 14:00:00 9.4 1.2 13.7 6.8 9.4 1.2 13.7 6.8 9 1.2 11.8 6.1 319 9 307 165 -11.5 0 -11.4 -11.6 11/25/2005 14:10:00 10.5 1.2 13.7 7.6 10.5 1.3 13.3 7.6 10.2 1.3 13.7 6.8 324 11 329 165 -11.5 0 -11.4 -11.6 11/25/2005 14:20:00 10.6 1.3 14.5 6.5 10.6 1.3 14.1 6.8 10.1 1.7 14.5 4.6 321 11 307 165 -11.6 0 -11.4 -11.8 11/25/2005 14:30:00 8.5 2.1 13.7 4.2 8.5 2.1 13.7 4.2 7.3 2.5 13 1.5 318 12 323 165 -11.7 0 -11.6 -11.8 11/25/2005 14:40:00 8.3 1.7 13 4.6 8.1 1.8 13.3 3.4 6.9 2.3 13 0.7 324 16 325 165 -11.6 0 -11.6 -11.8 11/25/2005 14:50:00 9.7 2 14.1 4.2 9.6 2.1 14.1 4.2 9 2.4 14.1 2.3 326 13 313 165 -11.6 0 -11.4 -11.8 11/25/2005 15:00:00 12.6 1.5 17.9 8.4 12.6 1.5 17.6 8 12.1 1.3 16.8 8.8 317 11 309 165 -11.5 0 -11.4 -11.8 11/25/2005 15:10:00 13.7 2.2 19.5 8.4 13.7 2.2 19.1 8.8 12.2 2 17.9 6.8 310 9 304 165 -11.5 0 -11.4 -11.6 11/25/2005 15:20:00 12.8 2.1 18.3 8.8 12.8 2.1 18.3 8.8 12.2 1.9 17.6 7.2 316 7 308 165 -11.5 0 -11.4 -11.6 11/25/2005 15:30:00 11.4 1.7 16.4 7.2 11.3 1.7 16.4 7.2 10.7 1.7 16.4 6.8 317 12 305 165 -11.4 0 -11.4 -11.6 11/25/2005 15:40:00 13.5 1.7 16.8 9.1 13.4 1.7 16.8 8.8 12.7 1.8 17.2 7.2 316 9 314 165 -11.5 0 -11.4 -11.8 11/25/2005 15:50:00 13.6 1.7 19.1 9.1 13.5 1.7 19.1 9.1 12.8 2.1 18.3 7.6 315 9 301 165 -11.6 0 -11.6 -11.8 11/25/2005 16:00:00 14.4 1.7 19.1 11.1 14.4 1.7 19.5 11.1 13.6 1.7 18.7 9.1 316 9 334 165 -11.7 0 -11.6 -11.8 11/25/2005 16:10:00 13.9 2.1 20.6 8 13.8 2.1 21 8 12.5 1.8 17.9 7.6 313 10 313 165 -11.8 0 -11.6 -11.8 11/25/2005 16:20:00 15.3 1.5 19.9 11.5 15.2 1.5 20.2 10.7 14.3 1.7 18.7 9.5 316 9 307 165 -11.8 0 -11.6 -11.8 11/25/2005 16:30:00 14.2 1.7 19.1 9.5 14.2 1.7 18.7 9.1 13.7 1.7 17.9 9.9 322 9 310 165 -11.9 0 -11.8 -12.2 11/25/2005 16:40:00 11.6 1.4 15.6 8 11.6 1.4 15.6 8 10.8 1.7 14.5 6.8 320 12 332 165 -11.9 0 -11.8 -12.2 11/25/2005 16:50:00 11.7 1.8 16.8 7.2 11.6 1.8 16.8 6.8 10.5 1.7 16.1 4.9 320 12 309 165 -12 0 -11.8 -12.2 11/25/2005 17:00:00 11.7 2.2 17.6 6.8 11.2 2.3 17.9 5.7 10.8 2.2 17.2 5.3 342 13 349 165 -12 0 -11.8 -12.2 11/25/2005 17:10:00 12.2 1.7 17.6 8.8 11.5 2.2 17.2 5.3 11.9 1.8 17.6 7.6 345 12 327 165 -12 0 -11.8 -12.2 11/25/2005 17:20:00 10.7 1.8 14.9 6.8 10.2 2.2 15.3 5.3 10.6 1.9 15.6 5.3 344 9 334 165 -12.1 0 -12 -12.2 11/25/2005 17:30:00 9.3 1.7 14.1 4.9 8.2 2.1 14.5 3.8 9.1 1.8 14.5 5.3 345 15 355 165 -12.1 0.1 -11.8 -12.4 11/25/2005 17:40:00 6.4 2 14.1 2.3 5.8 1.8 12.2 1.5 6.1 1.8 13.3 2.3 346 16 0 165 -12.2 0 -12 -12.4 11/25/2005 17:50:00 7.1 3.5 20.2 2.3 6.6 3.1 18.3 1.9 6.3 3.2 20.2 1.5 339 20 0 165 -12.4 0 -12.2 -12.6 11/25/2005 18:00:00 9.6 1.8 14.9 4.9 9.5 1.9 14.5 4.6 8.9 1.9 14.5 4.6 316 20 314 165 -12.1 0 -12 -12.2 11/25/2005 18:10:00 10.5 2.2 15.3 5.3 10.1 2.2 15.3 5.3 9.8 2 15.6 5.3 327 18 302 165 -12.2 0.1 -12 -12.4 11/25/2005 18:20:00 11.3 2.1 17.9 7.6 11.3 2.1 18.3 7.2 10.5 2.1 17.9 6.1 320 14 305 165 -12.3 0 -12.2 -12.4 11/25/2005 18:30:00 14.6 2 20.6 9.5 14.5 2.1 20.6 7.2 13.4 2.2 21 8 318 16 331 165 -12.2 0 -12 -12.2 11/25/2005 18:40:00 13.5 2.4 21 8.4 13.4 2.4 21.4 8.4 12.5 2.2 18.7 7.2 314 11 305 165 -12.1 0 -11.8 -12.2 11/25/2005 18:50:00 8.9 2.3 15.6 1.5 8.9 2.3 15.6 2.6 7.7 2.5 14.5 1.5 318 17 333 165 -12.2 0 -11.8 -12.4 11/25/2005 19:00:00 9.5 1.8 14.1 5.3 9.3 1.9 14.1 4.9 8.7 1.6 14.5 4.2 322 19 325 165 -12 0 -11.8 -12.2 11/25/2005 19:10:00 8.7 2.6 15.6 3.4 8.3 2.5 15.6 3.4 7.8 2.4 14.9 2.3 333 23 286 165 -11.9 0.1 -11.6 -12.2 11/25/2005 19:20:00 6.8 1.9 14.9 2.3 6.6 1.7 14.1 2.3 5.9 1.6 11.8 1.9 324 24 4 165 -11.8 0 -11.6 -11.8 11/25/2005 19:30:00 5.9 2.1 10.7 0.7 5.6 2 10.7 0.7 5.1 1.9 9.5 0.4 329 29 5 165 -11.9 0 -11.6 -12 11/25/2005 19:40:00 6.3 1.6 10.3 2.3 6 1.6 10.3 2.6 5.4 1.7 9.9 0.7 325 27 308 165 -12 0 -11.8 -12.2 11/25/2005 19:50:00 6.5 1.1 9.1 3.4 6.1 1.1 8.8 3.4 6.3 1 9.1 2.6 336 17 5 165 -11.9 0 -11.8 -12 11/25/2005 20:00:00 7.4 1.7 11.8 4.6 7.1 1.7 11.8 3 6.6 1.5 10.3 3.4 327 17 309 165 -12 0 -11.8 -12.2 11/25/2005 20:10:00 9.5 1.5 13.7 4.6 9.4 1.5 14.1 5.3 8.8 1.7 12.2 4.6 317 13 307 165 -11.8 0.1 -11.6 -12 11/25/2005 20:20:00 10 1.7 14.5 4.9 9.9 1.7 14.5 5.3 9.3 1.6 14.9 6.1 325 17 302 165 -11.6 0 -11.4 -11.8 11/25/2005 20:30:00 9.3 2.4 17.6 3.4 9.1 2.5 17.6 3 7.8 2.4 14.5 2.3 317 20 299 165 -11.6 0.1 -11.4 -11.8 11/25/2005 20:40:00 10.2 2.3 16.4 5.3 10.1 2.4 16.1 5.3 9.3 2.2 15.3 4.6 318 17 309 165 -11.5 0 -11.4 -11.6 11/25/2005 20:50:00 10.7 2.1 16.1 6.5 10.6 2.1 16.4 5.3 10 1.8 15.6 6.5 319 14 315 165 -11.4 0 -11.4 -11.6 11/25/2005 21:00:00 11 2.6 16.8 4.9 10.9 2.6 16.4 4.6 10.2 2.4 15.3 4.2 320 14 314 165 -11.5 0 -11.4 -11.6 11/25/2005 21:10:00 12.1 1.7 17.2 8 12.1 1.7 16.8 8 11.1 1.7 17.9 7.2 314 9 312 165 -11.5 0 -11.4 -11.6 11/25/2005 21:20:00 11.8 1.8 16.4 6.5 11.7 1.8 16.4 6.5 11 1.9 16.8 6.5 321 13 323 165 -11.6 0 -11.4 -11.8 11/25/2005 21:30:00 14.1 1.9 18.7 9.5 14 1.9 18.7 9.5 12.9 1.8 18.3 8 317 11 312 165 -11.5 0.1 -11.4 -11.6 11/25/2005 21:40:00 14.6 2.3 20.2 9.5 14.5 2.3 20.6 9.5 14.1 2.3 20.6 8.8 320 10 318 165 -11.3 0 -11.2 -11.4 11/25/2005 21:50:00 14.5 2.2 19.1 8.4 14.4 2.2 19.1 8.4 13.4 2.1 19.9 7.6 314 11 290 165 -11.3 0 -11.2 -11.4 11/25/2005 22:00:00 14.5 2.1 20.2 9.1 14.4 2 19.9 9.1 13.2 2 19.5 8 316 10 301 165 -11.3 0 -11.2 -11.4 11/25/2005 22:10:00 13.6 2.1 18.3 8.8 13.5 2 17.9 8.8 12.3 2.4 19.1 6.5 316 11 300 165 -11.3 0 -11 -11.4 11/25/2005 22:20:00 14.2 2 19.5 8.4 14.1 2 19.1 8 12.9 2.1 19.9 6.5 316 13 312 165 -11.1 0 -11 -11.4 11/25/2005 22:30:00 12.5 1.8 17.9 8.4 12.5 1.8 17.2 8.4 11.6 2.2 16.8 7.2 318 13 286 165 -11 0 -10.8 -11.2 11/25/2005 22:40:00 13 1.9 18.7 8.4 13 1.9 18.7 8.8 11.8 1.9 17.2 6.5 314 11 308 165 -10.9 0 -10.6 -11 11/25/2005 22:50:00 15.6 2.5 22.1 8 15.6 2.4 21.4 8 14.5 2.6 20.6 8 319 12 332 165 -10.8 0.1 -10.8 -11 11/25/2005 23:00:00 15.3 2.8 23.3 8.4 15.3 2.8 23.7 8.4 14.3 2.8 23.7 6.8 320 12 325 165 -10.8 0 -10.6 -11 11/25/2005 23:10:00 16.6 2 21 11.1 16.5 2 21 11.1 15 2.3 21 9.5 314 7 308 165 -10.9 0 -10.8 -11 11/25/2005 23:20:00 19 2 23.3 13.3 19 1.9 23.7 13 18 2.2 23.7 12.6 315 6 312 165 -10.8 0 -10.8 -11 11/25/2005 23:30:00 19 2.2 22.9 13 18.9 2.2 22.9 12.2 18 2.7 23.3 11.8 318 6 319 165 -10.8 0 -10.8 -11 11/25/2005 23:40:00 20 2.5 26 12.6 19.8 2.5 26.3 13 19.6 2.7 26.3 12.2 320 7 312 165 -10.8 0 -10.6 -11 11/25/2005 23:50:00 23.1 1.9 28.7 18.7 23 1.9 28.3 17.6 22.7 2.3 28.3 16.4 316 5 310 165 -10.8 0 -10.6 -11 11/26/2005 00:00:00 22.2 1.7 26.3 16.8 22.1 1.7 26.3 16.4 21.8 2.1 27.9 16.1 316 6 318 165 -10.8 0 -10.6 -10.8 11/26/2005 00:10:00 21.7 1.8 25.6 15.3 21.6 1.8 25.6 16.1 21.2 2.1 26.3 15.6 315 7 310 165 -10.7 0 -10.6 -11 11/26/2005 00:20:00 20.2 1.7 23.7 16.1 20.1 1.7 23.7 16.1 18.4 1.9 24 12.6 310 7 301 165 -10.8 0 -10.6 -11 11/26/2005 00:30:00 18.9 1.9 24 14.1 18.9 1.9 24.4 14.1 17.8 2 22.9 12.6 312 8 300 165 -10.8 0 -10.6 -10.8 11/26/2005 00:40:00 18.3 2.2 24 13.7 18.2 2.2 24 13.3 17.6 2.9 24.4 11.5 313 8 325 165 -10.8 0 -10.6 -10.8 11/26/2005 00:50:00 20.5 2.3 26 15.6 20.4 2.3 25.6 14.9 19.2 2.7 27.1 12.2 311 7 319 165 -10.7 0 -10.6 -11 11/26/2005 01:00:00 19.8 2.2 26.3 13.3 19.7 2.2 26.8 13.7 19.1 2.6 25.2 12.6 314 7 307 165 -10.6 0 -10.6 -10.8 11/26/2005 01:10:00 19.4 1.9 24.8 14.9 19.3 1.8 25.2 14.9 18.2 2.1 24 13.3 312 7 321 165 -10.6 0 -10.6 -10.8 11/26/2005 01:20:00 20 1.7 24.8 15.3 19.9 1.7 24.4 15.3 19.4 2.1 24.4 14.5 315 7 321 165 -10.5 0 -10.6 -10.8 11/26/2005 01:30:00 20.7 1.7 24 16.4 20.6 1.7 24.4 16.4 18.9 1.7 22.9 13 310 6 308 165 -10.5 0 -10.4 -10.6 11/26/2005 01:40:00 20.6 1.5 24.4 16.8 20.5 1.5 24 16.4 18.2 1.7 21.8 13.7 308 6 309 165 -10.5 0 -10.4 -10.6 11/26/2005 01:50:00 19.6 1.9 24.4 13 19.5 1.9 24.8 12.6 17.6 2.2 26 11.5 310 7 307 165 -10.5 0 -10.4 -10.6 11/26/2005 02:00:00 19.6 2.2 24 14.1 19.5 2.1 24 14.1 18.4 2.4 24.4 12.6 311 6 308 165 -10.5 0 -10.4 -10.6 11/26/2005 02:10:00 20.5 1.7 24.8 16.1 20.4 1.7 24.8 15.6 18.1 2.1 23.3 13.7 307 6 305 165 -10.5 0 -10.4 -10.6 11/26/2005 02:20:00 20.7 1.8 25.2 14.9 20.7 1.8 25.6 14.9 19.5 2.2 24.8 13.7 311 6 310 165 -10.4 0 -10.2 -10.6 11/26/2005 02:30:00 19.5 1.5 24 16.1 19.5 1.5 24 15.3 18.3 1.9 22.9 13.3 312 8 305 165 -10.3 0 -10.2 -10.6 11/26/2005 02:40:00 20.5 1.9 24.4 15.6 20.5 1.9 24.4 15.6 18.5 1.9 22.6 13.7 309 5 297 165 -10.3 0 -10.2 -10.4 11/26/2005 02:50:00 19.6 1.7 24.8 13.7 19.5 1.7 24 14.1 18.3 2 23.7 13.3 312 7 318 165 -10.3 0 -10.2 -10.4 11/26/2005 03:00:00 21.9 2 25.6 15.6 21.9 2.1 25.6 15.6 21.8 2 26 16.8 314 5 316 165 -10.2 0 -10 -10.4 11/26/2005 03:10:00 22.8 2 26.3 13.7 22.7 2 26.3 14.1 22 2.6 26.8 13.3 313 5 322 165 -10.1 0 -10 -10.2 11/26/2005 03:20:00 20.7 1.9 25.6 15.6 20.6 1.9 25.2 15.6 18.9 2.4 24.8 13 310 7 315 165 -10.2 0 -10.2 -10.4 11/26/2005 03:30:00 20.4 1.6 24.8 15.3 20.3 1.6 24.4 14.5 19.8 2.1 24.4 13.7 314 6 313 165 -10.2 0 -10.2 -10.2 11/26/2005 03:40:00 20.9 1.8 25.6 16.4 20.9 1.8 25.6 16.8 20.5 2.5 26.8 13.3 312 6 320 165 -10.1 0 -10 -10.2 11/26/2005 03:50:00 21.4 2 26 16.1 21.3 2 25.6 15.6 21.1 2.3 25.6 14.9 314 5 311 165 -10.1 0 -10 -10.2 11/26/2005 04:00:00 22.4 1.6 26.3 16.8 22.3 1.7 26.8 17.2 22.3 1.7 26 17.2 314 5 304 165 -10.1 0 -10 -10.2 11/26/2005 04:10:00 21 1.7 26 16.8 21 1.8 26 16.1 20.6 2.4 26 13.3 314 7 313 165 -10.1 0 -10 -10.2 11/26/2005 04:20:00 21.8 1.9 26.3 14.5 21.8 1.9 26.3 15.3 21 2.2 26 14.9 312 6 311 165 -10.2 0 -10 -10.2 11/26/2005 04:30:00 21.9 1.6 25.2 17.6 21.8 1.7 25.6 17.9 20.5 1.9 24 15.3 309 5 308 165 -10.1 0 -10 -10.2 11/26/2005 04:40:00 20.8 1.7 24.4 15.6 20.7 1.7 24 15.6 20 2.2 25.2 13 313 6 321 165 -10.1 0 -10 -10.2 11/26/2005 04:50:00 19.7 1.7 24.4 15.6 19.7 1.7 24 15.6 19.6 1.9 24.4 13.3 315 6 313 165 -10.1 0 -10 -10.2 11/26/2005 05:00:00 19.8 1.7 24.8 15.3 19.7 1.7 24.4 15.6 19.1 2.2 25.6 13.7 314 6 319 165 -10 0 -10 -10.2 11/26/2005 05:10:00 21.2 1.8 25.6 14.1 21.2 1.7 25.2 14.9 21.1 2.1 26.3 13.7 315 5 318 165 -9.9 0 -9.7 -10.2 11/26/2005 05:20:00 20.2 1.5 23.7 16.4 20.1 1.5 23.7 16.1 19.5 2 24 13.3 315 6 312 165 -10 0 -9.7 -10.2 11/26/2005 05:30:00 19.3 1.7 25.6 14.5 19.2 1.7 25.2 14.1 18.9 1.9 24.4 13.3 315 6 314 165 -9.9 0 -9.7 -10.2 11/26/2005 05:40:00 18.4 1.7 22.6 13.7 18.4 1.8 22.6 13.7 17.4 1.7 21.8 13.3 312 6 307 165 -9.9 0 -9.7 -10.2 11/26/2005 05:50:00 19.1 1.6 23.7 13.3 19 1.6 23.3 13 18.7 1.8 23.3 13.7 318 7 317 165 -9.9 0 -9.7 -10 11/26/2005 06:00:00 20.4 1.9 26 15.3 20.3 2 25.2 15.3 20.1 2.1 24.4 13.7 321 5 328 165 -9.9 0 -9.7 -10 11/26/2005 06:10:00 21.3 1.4 24.8 17.6 21.2 1.4 24.8 17.2 21.3 1.5 24.8 17.2 318 4 320 165 -9.7 0 -9.5 -9.7 11/26/2005 06:20:00 20.2 1.5 23.7 16.4 20.2 1.5 23.7 16.4 19.5 1.7 23.3 14.9 314 6 312 165 -9.5 0 -9.3 -9.7 11/26/2005 06:30:00 19.4 1.3 22.9 15.6 19.3 1.3 22.9 16.1 18.1 1.4 22.1 14.9 312 7 307 165 -9.4 0 -9.3 -9.7 11/26/2005 06:40:00 20 1.5 24 14.5 19.9 1.6 24 14.1 19.8 1.7 24.8 15.3 317 6 327 165 -9.4 0 -9.3 -9.7 11/26/2005 06:50:00 20.3 1.5 23.3 16.1 20.3 1.5 23.3 15.6 19.5 1.6 23.3 14.9 313 7 303 165 -9.5 0 -9.3 -9.7 11/26/2005 07:00:00 18.4 2 23.7 14.5 18.4 2 24 14.5 17.9 2 22.6 13 315 7 309 165 -9.6 0 -9.3 -9.7 11/26/2005 07:10:00 19.8 1.4 22.6 16.1 19.8 1.4 22.1 15.6 19.5 1.5 22.9 14.1 313 5 318 165 -9.5 0 -9.3 -9.7 11/26/2005 07:20:00 19.4 1.5 22.6 14.9 19.4 1.5 22.6 15.3 18.7 2 22.6 14.1 311 4 304 165 -9.4 0 -9.1 -9.5 11/26/2005 07:30:00 17.4 1.1 21 14.5 17.4 1.1 21 13.7 16 1.6 20.6 12.2 309 5 312 165 -9.3 0 -9.1 -9.3 11/26/2005 07:40:00 18.1 1.5 21.4 14.1 18.1 1.5 21.4 14.1 16.6 2 21.4 11.1 311 5 310 165 -9.2 0 -9.1 -9.3 11/26/2005 07:50:00 18.9 1.6 24.4 14.9 18.8 1.6 24.8 14.9 17.7 2.3 24 12.2 312 6 308 165 -9.2 0 -9.1 -9.3 11/26/2005 08:00:00 20.4 1.5 24 16.1 20.4 1.5 24 16.4 20.1 1.7 24.8 14.1 315 5 317 165 -9.1 0 -9.1 -9.3 11/26/2005 08:10:00 19.3 1.5 23.3 15.3 19.2 1.5 22.9 15.3 19 1.8 22.6 14.5 315 6 308 165 -9.1 0 -8.9 -9.1 11/26/2005 08:20:00 19.1 1.8 25.6 14.1 19 1.8 25.6 14.5 18.4 2.3 24 12.2 315 8 328 165 -9.1 0 -8.9 -9.3 11/26/2005 08:30:00 18.5 1.2 22.1 15.3 18.5 1.2 22.6 15.3 17.6 1.2 20.6 13.3 312 6 307 165 -9 0 -8.9 -9.1 11/26/2005 08:40:00 17.7 1.3 21 14.1 17.6 1.3 21.4 14.1 16.6 1.8 21 11.8 312 6 313 165 -9 0 -8.9 -9.1 11/26/2005 08:50:00 17.7 1.3 20.6 14.1 17.6 1.3 20.6 14.1 16.3 1.6 20.2 11.8 312 6 308 165 -9 0 -8.9 -9.1 11/26/2005 09:00:00 17.8 1.6 21.4 11.8 17.8 1.6 21.4 12.2 15.8 1.8 19.9 10.3 309 5 309 165 -9 0 -8.9 -9.1 11/26/2005 09:10:00 17.8 1.5 21 14.1 17.7 1.5 20.6 13.7 15.8 1.6 19.9 12.2 309 5 306 165 -8.9 0 -8.9 -9.1 11/26/2005 09:20:00 18.8 1.3 22.6 14.1 18.7 1.3 21.8 14.9 16.8 1.8 21.8 11.8 310 5 302 165 -8.9 0 -8.7 -8.9 11/26/2005 09:30:00 19.2 1.6 23.3 14.5 19.1 1.5 22.9 14.9 17.8 2 22.9 13 313 7 317 165 -8.8 0 -8.7 -8.9 11/26/2005 09:40:00 19.6 1.7 23.3 14.9 19.5 1.7 23.3 14.1 17.6 1.7 22.1 12.6 309 6 305 165 -8.8 0 -8.7 -8.9 11/26/2005 09:50:00 20.2 1.9 26 14.9 20.1 1.9 26 14.9 18.3 2 24.8 13.3 308 6 307 165 -8.7 0 -8.5 -8.9 11/26/2005 10:00:00 19.5 2 24 14.5 19.4 2 23.7 14.5 17.4 2.4 24.4 11.8 309 5 299 165 -8.5 0.1 -8.1 -8.5 11/26/2005 10:10:00 20.6 2.3 25.2 14.1 20.5 2.3 25.2 13.7 19.4 2.4 25.2 11.1 311 5 316 165 -8.3 0.1 -8.1 -8.5 11/26/2005 10:20:00 22.7 1.7 26.8 17.2 22.7 1.7 26.8 17.6 21.6 2 26.3 13.7 311 4 318 165 -8.1 0.1 -8.1 -8.3 11/26/2005 10:30:00 21.9 1.5 26.3 17.2 21.9 1.5 26.3 17.2 21 1.7 26 16.4 312 4 307 165 -8 0 -7.6 -8.1 11/26/2005 10:40:00 20.9 1.8 24.4 14.9 20.9 1.8 24.8 15.3 20.6 2.1 24.8 14.5 315 5 317 165 -8 0 -7.6 -8.1 11/26/2005 10:50:00 21.7 1.7 25.2 17.2 21.6 1.7 25.6 17.6 21.3 1.9 25.2 15.6 316 5 325 165 -7.9 0 -7.6 -8.1 11/26/2005 11:00:00 21.7 1.5 24.8 15.6 21.7 1.5 25.2 15.6 21.3 1.7 24.8 15.6 314 5 315 165 -7.6 0 -7.4 -7.6 11/26/2005 11:10:00 21.5 1.9 25.6 16.1 21.5 1.9 26 16.1 21 2 24.8 15.3 316 6 310 165 -7.6 0 -7.4 -7.6 11/26/2005 11:20:00 21.9 1.9 26 16.1 21.8 1.9 25.6 16.4 20.9 2.2 26 14.9 314 6 310 165 -7.3 0 -7 -7.6 11/26/2005 11:30:00 22 1.8 27.1 16.8 21.9 1.8 27.1 16.8 20.7 2 26.3 12.2 312 6 304 165 -6.9 0.1 -6.8 -7.2 11/26/2005 11:40:00 22.3 1.8 25.6 15.6 22.2 1.8 25.6 15.6 21.3 2.2 26 14.1 314 6 312 165 -6.9 0 -6.6 -7 11/26/2005 11:50:00 22.1 1.6 25.6 17.2 22 1.6 26 17.2 21.7 1.8 25.6 14.9 315 5 309 165 -6.7 0 -6.6 -7 11/26/2005 12:00:00 21.4 1.7 26 14.9 21.3 1.7 26 15.3 21 1.7 26 14.9 316 6 319 165 -6.5 0 -6.4 -6.8 11/26/2005 12:10:00 20.3 1.4 23.7 15.6 20.3 1.4 23.3 16.1 18.8 1.6 23.3 14.5 311 6 309 165 -6.6 0 -6.4 -6.8 11/26/2005 12:20:00 20.9 1.6 25.2 16.4 20.9 1.6 25.2 16.1 19.7 1.7 24 13.7 313 6 312 165 -6.7 0 -6.6 -6.8 11/26/2005 12:30:00 21.1 1.7 25.2 17.6 21 1.8 25.2 17.6 20.2 1.9 24 15.6 313 6 309 165 -6.7 0 -6.6 -6.8 11/26/2005 12:40:00 21.5 1.7 25.2 16.8 21.4 1.7 25.6 16.1 20.7 1.9 25.2 15.6 314 6 308 165 -6.7 0 -6.6 -6.8 11/26/2005 12:50:00 21.3 1.9 26.3 15.3 21.2 1.8 26.3 16.4 20.4 1.8 25.2 14.9 314 7 322 165 -6.5 0.1 -6.4 -6.8 11/26/2005 13:00:00 22.9 1.7 27.5 16.4 22.9 1.7 27.5 16.4 22.3 1.8 26.8 16.1 315 5 314 165 -6.4 0 -6.1 -6.6 11/26/2005 13:10:00 23.7 1.8 28.7 17.9 23.7 1.8 28.3 18.7 23 1.9 29.1 17.9 315 5 313 165 -6.2 0 -6.1 -6.4 11/26/2005 13:20:00 22.9 1.8 28.7 17.6 22.9 1.8 28.7 17.6 22.1 2 26.8 16.4 315 5 318 165 -6.1 0 -5.9 -6.4 11/26/2005 13:30:00 22.7 1.5 28.3 18.3 22.6 1.5 28.7 18.7 22.2 1.7 26.3 17.6 316 5 325 165 -6.2 0.1 -5.9 -6.4 11/26/2005 13:40:00 23 1.8 26.8 17.6 23 1.9 26.8 17.6 22.7 2.2 27.5 16.8 316 5 323 165 -6.2 0 -6.1 -6.4 11/26/2005 13:50:00 22.5 1.3 25.2 18.7 22.4 1.3 25.6 18.3 22.2 1.5 26 17.2 316 5 315 165 -6.3 0 -6.1 -6.4 11/26/2005 14:00:00 24.4 2.1 30.2 18.3 24.3 2.2 30.6 17.9 23.7 2.3 28.7 16.4 315 5 315 165 -6.3 0.1 -6.1 -6.6 11/26/2005 14:10:00 25.7 1.5 29.4 21.4 25.7 1.5 29.1 21.8 25.6 1.9 30.9 18.7 316 5 315 165 -6.4 0 -6.4 -6.6 11/26/2005 14:20:00 25.5 1.5 29.8 21.4 25.5 1.6 29.4 21 25.5 1.7 30.2 21 317 4 325 165 -6.5 0 -6.4 -6.6 11/26/2005 14:30:00 26.7 1.4 31.3 21.4 26.7 1.5 30.9 20.6 26.5 1.6 31.8 21 315 3 313 165 -6.4 0 -6.1 -6.6 11/26/2005 14:40:00 26.1 1.7 30.2 21 26 1.7 30.2 21 25.8 1.8 29.8 21 316 5 311 165 -6.4 0 -6.1 -6.6 11/26/2005 14:50:00 26.4 1.7 30.9 20.6 26.3 1.7 30.2 20.6 25.8 2 31.3 18.3 316 4 318 165 -6.4 0 -6.1 -6.6 11/26/2005 15:00:00 26.1 1.9 30.2 19.1 26.1 2 29.8 18.7 25.7 2 30.6 18.7 315 5 312 165 -6.5 0 -6.1 -6.6 11/26/2005 15:10:00 27.3 1.4 30.9 21.4 27.2 1.4 30.9 21.8 26.6 1.7 30.6 21 314 4 308 165 -6.4 0 -6.1 -6.6 11/26/2005 15:20:00 27.1 1.5 30.6 23.3 27 1.5 30.6 23.3 26.7 1.7 30.6 21 314 4 307 165 -6.5 0 -6.1 -6.8 11/26/2005 15:30:00 26.2 1.9 30.6 18.3 26.2 2 30.6 18.7 26 2.2 30.6 16.1 316 5 311 165 -6.5 0 -6.4 -6.6 11/26/2005 15:40:00 24.6 1.7 29.1 19.9 24.5 1.7 29.1 19.5 24 2 29.1 17.9 314 5 314 165 -6.5 0.1 -6.4 -6.6 11/26/2005 15:50:00 24.2 1.7 29.1 18.3 24.2 1.8 29.1 18.3 23.8 2.2 29.1 17.2 315 5 313 165 -6.5 0 -6.1 -6.6 11/26/2005 16:00:00 24.9 1.9 29.4 19.5 24.9 1.9 29.4 19.1 24.7 2.1 29.4 18.7 316 5 314 165 -6.5 0 -6.4 -6.6 11/26/2005 16:10:00 26.1 1.5 29.8 21.4 26.1 1.6 30.2 21 25.9 1.6 30.2 19.5 317 5 316 165 -6.6 0 -6.6 -6.8 11/26/2005 16:20:00 25.1 1.9 28.7 18.3 25.1 1.9 28.7 17.6 24.9 2 29.4 18.3 316 5 315 165 -6.7 0 -6.6 -6.8 11/26/2005 16:30:00 25.8 1.7 29.8 21.4 25.7 1.7 29.4 21 25.6 1.9 30.6 20.2 316 5 319 165 -6.7 0 -6.6 -6.8 11/26/2005 16:40:00 26 2.5 31.8 19.1 26 2.5 31.8 19.5 25.3 2.6 32.4 18.3 313 5 318 165 -6.6 0.1 -6.4 -6.8 11/26/2005 16:50:00 26.9 1.9 30.9 19.9 26.9 1.9 30.9 20.2 26.4 2.2 30.9 17.6 313 5 312 165 -6.4 0 -6.1 -6.6 11/26/2005 17:00:00 27.5 1.5 31.8 22.9 27.5 1.5 32.1 23.3 27 1.8 31.8 21 313 4 310 165 -6.4 0 -6.1 -6.6 11/26/2005 17:10:00 26.7 2 32.4 21 26.7 2.1 31.8 20.6 26.6 2.1 32.4 20.6 316 5 321 165 -6.1 0 -5.9 -6.6 11/26/2005 17:20:00 27.3 1.8 33.2 21.4 27.2 1.8 33.2 21.8 26.9 2 33.6 20.2 315 6 307 165 -6 0.1 -5.7 -6.1 11/26/2005 17:30:00 26.8 1.7 31.8 22.6 26.8 1.7 32.1 21.8 26.3 1.9 31.3 20.2 315 5 314 165 -5.9 0 -5.5 -6.1 11/26/2005 17:40:00 25.4 1.7 31.3 20.2 25.3 1.7 30.9 20.6 24.9 1.9 29.4 19.1 316 6 307 165 -5.9 0 -5.5 -6.1 11/26/2005 17:50:00 24.8 2.1 29.1 17.9 24.7 2 29.4 17.6 23.6 2.2 29.1 16.1 314 6 307 165 -5.9 0 -5.7 -6.1 11/26/2005 18:00:00 25.1 2.4 30.9 17.9 25.1 2.4 31.3 17.6 23.9 2.4 30.9 17.2 312 7 304 165 -5.9 0 -5.7 -6.1 11/26/2005 18:10:00 24.4 1.8 30.2 19.1 24.3 1.8 30.2 19.1 23.6 2 29.8 18.3 314 5 307 165 -6.2 0.1 -6.1 -6.4 11/26/2005 18:20:00 23.5 2 28.7 18.7 23.4 2 28.7 18.3 22.6 2 27.5 17.6 314 6 306 165 -6.1 0 -5.9 -6.6 11/26/2005 18:30:00 23.9 2.2 28.7 16.8 23.8 2.1 28.7 16.8 22.4 2.4 27.9 15.6 310 6 310 165 -6.1 0 -5.7 -6.1 11/26/2005 18:40:00 22.7 2.5 34.4 16.1 22.5 2.5 34 16.4 21.4 2.7 29.4 14.9 314 9 292 165 -5.7 0.3 -5.3 -6.1 11/26/2005 18:50:00 22.4 2.6 30.9 15.3 22.2 2.5 30.6 14.9 20.9 2.5 26.8 13 312 8 309 165 -5.5 0 -5.5 -5.7 11/26/2005 19:00:00 22.3 2.3 27.9 14.5 22.2 2.2 27.1 14.9 21.1 2.3 27.1 15.3 315 8 316 165 -5.7 0 -5.3 -5.7 11/26/2005 19:10:00 23.4 2.2 27.9 16.1 23.3 2.2 27.9 16.1 22.2 2.3 27.5 14.1 313 6 307 165 -5.6 0 -5.5 -5.7 11/26/2005 19:20:00 23.3 2.1 28.7 17.2 23.2 2.1 28.3 17.2 22.2 2.4 27.5 14.5 315 8 310 165 -5.6 0 -5.5 -5.7 11/26/2005 19:30:00 23.8 2.1 29.8 17.6 23.7 2.1 29.8 17.2 23.2 2.4 29.1 15.6 316 7 310 165 -5.5 0.1 -5.3 -5.7 11/26/2005 19:40:00 25.1 2.3 30.6 18.7 25 2.4 30.6 18.3 24.3 2.4 31.3 18.3 315 7 321 165 -5.3 0.1 -5 -5.5 11/26/2005 19:50:00 24.2 2.6 32.1 16.1 24.1 2.6 31.3 14.9 23.5 2.9 30.9 15.3 316 7 316 165 -5.2 0.1 -5 -5.5 11/26/2005 20:00:00 22.5 2.5 31.8 14.5 22.3 2.5 31.8 14.9 21 2.7 30.6 14.5 313 10 310 165 -5 0 -4.8 -5.5 11/26/2005 20:10:00 21.8 2.5 29.4 15.3 21.7 2.5 29.4 16.1 20.2 2.6 27.9 13.3 312 8 310 165 -5 0.1 -4.6 -5.3 11/26/2005 20:20:00 20.4 2 27.9 15.6 20.3 2 27.1 15.6 19.2 2.2 25.2 12.2 314 9 312 165 -5.2 0.1 -5 -5.5 11/26/2005 20:30:00 20.4 2.4 27.9 12.6 20.3 2.4 27.1 12.6 19.2 2.4 26.8 12.2 315 10 303 165 -5 0.1 -4.6 -5.7 11/26/2005 20:40:00 21 2.3 28.7 15.6 20.9 2.2 28.3 15.6 19.9 2.3 25.2 13.7 314 8 307 165 -4.8 0.2 -4.4 -5 11/26/2005 20:50:00 22.1 2.2 31.3 16.4 21.9 2.2 30.6 16.4 20.7 2.5 27.5 14.9 313 8 313 165 -4.8 0.1 -4.4 -5 11/26/2005 21:00:00 21 2.3 28.7 16.1 20.9 2.2 27.5 15.6 20.3 2.5 27.1 13 318 9 316 165 -4.7 0.2 -4.4 -5 11/26/2005 21:10:00 19.6 2.5 27.1 13.7 19.4 2.4 26 13 19.1 2.4 25.2 13.7 327 12 3 165 -4.7 0 -4.4 -5 11/26/2005 21:20:00 19.9 1.5 23.3 15.6 19.6 1.7 22.9 14.9 19.4 1.8 24.4 14.5 329 11 326 165 -4.7 0 -4.4 -5 11/26/2005 21:30:00 20 2.6 27.5 13 19.9 2.6 27.5 13.7 18.8 2.5 26.8 12.2 320 10 314 165 -4.8 0 -4.4 -5 11/26/2005 21:40:00 18 1.8 22.6 12.6 18 1.8 22.9 13.3 16.5 2.3 23.3 9.5 318 12 314 165 -4.8 0 -4.4 -5 11/26/2005 21:50:00 16.5 2.2 22.9 11.5 16.3 2.2 22.9 9.5 15.6 2.4 22.9 9.9 333 13 332 165 -4.7 0 -4.4 -5 11/26/2005 22:00:00 17.4 2.2 24 10.7 16.9 2.5 24.8 8 16.6 2.3 23.3 9.9 339 11 342 165 -4.5 0 -4.4 -4.6 11/26/2005 22:10:00 17.5 2.5 22.9 10.7 17.2 2.8 23.3 9.1 17 2.6 23.3 10.7 333 13 328 165 -4.7 0 -4.4 -4.8 11/26/2005 22:20:00 19.1 2.7 26.3 13.3 18.5 3.1 26.8 8.8 18.9 2.9 25.2 12.2 340 10 317 165 -4.3 0.1 -3.9 -4.6 11/26/2005 22:30:00 16 2.6 22.6 10.7 15.6 2.5 21.8 10.7 15.6 2.8 23.3 9.1 334 11 348 165 -4.2 0 -3.9 -4.4 11/26/2005 22:40:00 13.7 1.9 19.9 9.1 13.6 1.8 19.9 9.1 12.8 2.1 18.7 8.4 326 12 331 165 -4.4 0.1 -4.2 -4.8 11/26/2005 22:50:00 14.9 2 21.8 11.1 14.8 2 22.1 11.1 14.1 2.2 21 9.5 323 10 328 165 -4.7 0.1 -4.4 -4.8 11/26/2005 23:00:00 17 2.1 25.2 12.6 16.8 2.1 25.2 12.2 16.5 2.3 25.6 9.9 330 13 349 165 -4.4 0 -4.2 -4.6 11/26/2005 23:10:00 17.6 1.7 22.9 13.3 17.3 1.8 22.6 9.9 17.2 1.6 21 13.3 330 13 359 165 -4.3 0 -3.9 -4.4 11/26/2005 23:20:00 18 1.8 23.7 13 17.8 1.8 23.7 13 17.3 1.8 22.6 12.2 319 9 310 165 -4.3 0 -4.2 -4.6 11/26/2005 23:30:00 17.6 1.5 22.1 12.6 17.3 1.6 21.8 13 16.8 1.6 21.4 12.6 328 13 310 165 -4.3 0 -4.2 -4.6 11/26/2005 23:40:00 18.8 2.5 26.8 13 18.3 2.5 26 11.5 18.6 2.3 26 13.7 339 11 340 165 -3.9 0 -3.5 -4.2 11/26/2005 23:50:00 20.1 2.4 26.8 14.5 19.5 2.7 26.8 11.1 19.9 2.6 25.2 13.3 339 11 345 165 -3.8 0.1 -3.5 -3.9 11/27/2005 00:00:00 19.1 2.8 26 12.6 18.5 2.9 26.8 11.1 19 2.9 26.8 12.2 337 12 337 165 -3.6 0 -3.5 -3.7 11/27/2005 00:10:00 18.5 2.5 25.6 13 17.9 2.8 26 9.1 18.2 2.8 26.3 11.5 341 10 350 165 -3.6 0 -3.5 -3.7 11/27/2005 00:20:00 17.5 1.8 22.9 13.3 17 2 21.8 11.8 17 1.9 22.6 13 336 13 359 165 -3.7 0 -3.5 -3.9 11/27/2005 00:30:00 16.2 1.7 20.6 11.5 16.1 1.8 21 11.5 15.4 1.9 20.6 9.9 326 10 328 165 -3.9 0 -3.5 -4.2 11/27/2005 00:40:00 14.2 2.1 19.1 8.4 14.1 2.1 18.7 8 13.3 2.2 19.5 5.7 326 11 313 165 -3.9 0 -3.7 -4.2 11/27/2005 00:50:00 15.7 2.2 22.1 9.9 14.7 2.2 21 9.9 14.8 2.2 21.4 8.8 343 10 355 165 -3.6 0.1 -3.3 -3.9 11/27/2005 01:00:00 16.9 2.1 22.6 10.7 15.6 2.6 22.1 8.4 15.7 2.4 21.8 9.1 346 12 344 165 -3.5 0 -3.3 -3.5 11/27/2005 01:10:00 17.5 2.3 23.3 11.5 16.5 2.3 22.9 11.5 16.9 2.3 23.3 11.1 342 12 3 165 -3.5 0 -3.3 -3.7 11/27/2005 01:20:00 15.6 1.6 19.5 11.1 15.4 1.7 20.2 11.1 15 1.5 19.1 10.7 337 10 340 165 -3.6 0 -3.5 -3.7 11/27/2005 01:30:00 16.8 1.8 23.7 11.5 15.8 1.9 22.9 9.5 16 2.2 22.1 10.7 346 9 342 165 -3.4 0.1 -3 -3.9 11/27/2005 01:40:00 18.1 1.7 22.9 13.3 17 2.3 23.3 11.5 17.5 1.9 22.6 13 345 9 345 165 -3 0 -2.8 -3 11/27/2005 01:50:00 18.4 2.3 24.4 12.2 17.3 2.8 24.8 8.8 17.7 2.4 23.7 11.5 342 11 345 165 -2.9 0 -2.8 -3 11/27/2005 02:00:00 16.8 2.1 23.3 10.3 15.9 2 22.6 10.3 15.8 2.3 22.1 9.9 343 11 356 165 -3 0 -2.8 -3.3 11/27/2005 02:10:00 17.1 2 22.9 12.2 16.8 1.9 21.8 11.1 16.5 2.3 21.8 11.8 332 13 354 165 -3.2 0.1 -2.8 -3.5 11/27/2005 02:20:00 15.9 1.3 19.1 12.6 15.8 1.3 19.9 12.2 14.6 1.5 19.1 9.9 317 10 316 165 -3.7 0.1 -3.5 -4.2 11/27/2005 02:30:00 15.1 1.9 20.6 10.3 15 1.9 21.4 9.9 13.9 1.8 19.1 8.8 317 9 311 165 -4 0.1 -3.7 -4.4 11/27/2005 02:40:00 14.6 1.7 19.5 9.5 14 1.9 20.6 9.1 14.2 1.7 19.1 10.3 339 15 341 165 -3.7 0.2 -3.3 -4.2 11/27/2005 02:50:00 14.2 2.3 22.1 8.8 13.9 2.4 20.2 9.1 13.7 2.5 22.1 9.1 335 12 351 165 -3 0 -2.8 -3.3 11/27/2005 03:00:00 14.1 1.8 19.5 9.1 13.5 2.5 18.3 6.5 13.5 2.1 17.9 6.5 341 11 342 165 -3.3 0 -3 -3.3 11/27/2005 03:10:00 12.7 1.9 18.3 8 12 2 17.9 5.7 11.7 2 17.6 5.7 343 10 349 165 -3.4 0 -3.3 -3.5 11/27/2005 03:20:00 12.3 2.2 19.1 7.2 11.8 2.4 17.9 6.5 10.9 2.2 17.2 5.7 341 11 352 165 -3.3 0 -3.3 -3.5 11/27/2005 03:30:00 12.7 1.5 17.2 8.8 12.1 1.7 16.4 6.8 11.9 1.6 16.4 7.2 341 11 347 165 -3.2 0 -3 -3.3 11/27/2005 03:40:00 12.5 1.8 18.3 8.4 12.2 1.8 18.7 8 11.8 1.8 18.3 7.6 335 12 343 165 -3.3 0 -3.3 -3.5 11/27/2005 03:50:00 11.4 1.7 16.4 7.6 11.3 1.7 16.1 6.8 10.3 1.5 14.5 6.8 328 14 337 165 -3.5 0 -3.3 -3.5 11/27/2005 04:00:00 11.2 1.3 15.3 7.2 11.1 1.3 15.3 7.6 9.8 1.5 13.3 6.1 317 13 319 165 -3.6 0 -3.5 -3.7 11/27/2005 04:10:00 13.9 1.5 18.7 9.9 13.8 1.6 18.7 10.3 12.6 1.7 17.6 6.8 314 8 307 165 -3.6 0.1 -3.5 -3.9 11/27/2005 04:20:00 11.3 1.5 14.9 7.2 11.3 1.5 14.5 7.2 10.3 1.4 13.3 7.2 319 10 305 165 -3.9 0.1 -3.5 -4.2 11/27/2005 04:30:00 10.2 1.7 14.9 6.5 10.2 1.7 14.9 6.5 8.6 1.9 12.6 4.9 312 13 321 165 -4.2 0 -3.9 -4.4 11/27/2005 04:40:00 9.2 1.7 14.1 6.1 9 1.7 13.7 6.1 7.9 1.7 13.3 3.8 325 19 354 165 -3.9 0 -3.5 -4.2 11/27/2005 04:50:00 8.2 1.2 11.5 5.3 8.1 1.2 11.5 5.3 7.3 1.1 11.1 4.6 315 14 298 165 -3.7 0 -3.5 -3.9 11/27/2005 05:00:00 8.6 1.9 13.7 4.6 8.6 1.8 13.7 4.9 7.2 1.5 13.3 3.8 307 13 291 165 -4 0.1 -3.7 -4.4 11/27/2005 05:10:00 10.6 1.5 13.7 6.5 10.4 1.5 13.3 6.1 8.6 1.5 12.6 4.9 298 9 302 165 -4 0.1 -3.9 -4.4 11/27/2005 05:20:00 11.5 1.8 17.6 6.5 11.4 1.7 17.6 6.5 9.5 1.7 16.1 5.7 305 9 307 165 -4 0.1 -3.7 -4.4 11/27/2005 05:30:00 9.8 1.7 14.1 5.3 9.7 1.7 14.1 4.9 8.5 1.3 14.1 4.6 316 13 306 165 -3.9 0 -3.5 -4.2 11/27/2005 05:40:00 7.8 1.2 13 5.3 7.7 1.2 13 4.9 6.9 1.4 11.8 3.4 321 15 334 165 -3.5 0 -3.3 -3.5 11/27/2005 05:50:00 7.3 1.7 11.8 3.8 7.1 1.7 12.2 3.4 6.7 1.6 12.6 3 322 13 344 165 -3.1 0.2 -2.6 -3.5 11/27/2005 06:00:00 8 2.4 13.3 3.8 8 2.4 13 3.4 7.2 2.5 12.6 2.6 325 17 335 165 -2.8 0.2 -2.6 -3 11/27/2005 06:10:00 7 1.3 10.3 3.8 6.9 1.3 9.9 3.4 6 1.2 9.9 3 312 18 330 165 -2.9 0.1 -2.6 -3.3 11/27/2005 06:20:00 6.6 1.1 9.5 3.8 6.5 1.2 9.5 3.8 5.9 1.2 9.5 3 326 16 322 165 -3 0.1 -2.6 -3.3 11/27/2005 06:30:00 6.6 1.4 10.3 2.6 6.5 1.4 11.1 2.6 5.8 1.4 10.3 2.6 325 15 324 165 -2.7 0 -2.6 -3 11/27/2005 06:40:00 3.9 1.7 9.1 1.1 4 1.8 9.5 0.4 3.6 1.7 8 0.7 294 23 287 165 -3.2 0 -2.8 -3.5 11/27/2005 06:50:00 2.8 1.7 8 0.4 2.6 1.7 7.6 0.4 2.2 1.5 6.1 0.4 315 49 318 165 -3.8 0.2 -3.3 -4.4 11/27/2005 07:00:00 1.4 1.1 5.3 0.4 1.4 1 5.3 0.4 1.2 0.9 4.2 0.4 344 102 333 165 -4.3 0 -4.2 -4.6 11/27/2005 07:10:00 3.9 1.9 9.9 0.4 3.6 1.7 8.8 0.7 2.9 1.5 8.4 0.4 306 64 21 165 -4 0 -3.7 -4.4 11/27/2005 07:20:00 2.3 1.1 5.7 0.4 2.4 1.1 6.1 0.4 3 1.1 5.3 0.4 229 29 241 165 -4.3 0.1 -3.9 -4.6 11/27/2005 07:30:00 2.5 1.3 6.1 0.4 2.6 1.3 6.5 0.4 2.8 1.2 6.1 0.4 271 39 229 165 -4 0.1 -3.5 -4.4 11/27/2005 07:40:00 2.6 1.3 5.3 0.4 2.7 1.3 5.7 0.4 3.5 1.1 6.1 0.7 217 24 241 165 -4.4 0 -3.9 -4.6 11/27/2005 07:50:00 3.2 1.2 6.1 0.7 3.3 1.2 6.1 0.7 3.8 1.2 6.5 1.1 230 21 236 165 -4.3 0 -3.9 -4.6 11/27/2005 08:00:00 3.8 1.3 6.8 0.7 4 1.3 6.8 1.1 4 1.3 6.5 0.7 239 26 238 165 -4.6 0 -4.4 -4.6 11/27/2005 08:10:00 5.4 1 8.8 2.3 5.5 1 8 2.3 6 0.8 8 3.4 237 11 241 165 -4.5 0 -4.4 -4.6 11/27/2005 08:20:00 5.7 1.3 9.1 2.6 6.3 1.1 9.5 2.6 6.2 1.2 8.4 2.3 254 15 240 165 -4.4 0 -4.2 -4.6 11/27/2005 08:30:00 5.8 2 10.7 1.1 5.8 1.9 11.1 0.7 5.1 1.6 9.1 1.1 308 38 23 165 -3.6 0.4 -3 -4.4 11/27/2005 08:40:00 6.2 1.8 9.9 1.5 6.1 1.8 10.3 1.9 5.6 1.7 9.5 1.9 324 22 338 165 -2.6 0.4 -1.9 -3.5 11/27/2005 08:50:00 3 1.7 9.1 0.4 3.1 1.7 8.8 0.4 3.1 1.5 8 0.7 283 33 337 165 -2.7 0.1 -2.4 -3 11/27/2005 09:00:00 4.9 1.5 8.8 2.3 5.3 1.7 9.9 1.9 4.9 1.7 9.1 0.7 287 32 264 165 -3.1 0.1 -2.8 -3.3 11/27/2005 09:10:00 8.6 1.1 11.1 5.3 8.8 1.1 11.5 5.3 8 1.4 11.5 4.6 285 9 294 165 -3.1 0 -2.8 -3.3 11/27/2005 09:20:00 9.5 1.5 14.1 6.1 9.6 1.5 14.1 6.1 8.7 1.7 14.1 5.3 288 8 281 165 -3.2 0 -3 -3.3 11/27/2005 09:30:00 11.5 1.2 14.9 8 11.6 1.2 14.5 8 10.4 1.5 14.5 6.5 289 7 294 165 -3 0 -2.8 -3.3 11/27/2005 09:40:00 10.6 1.7 14.9 5.7 10.6 1.7 14.9 6.1 9 1.9 13.7 4.6 295 9 290 165 -2.9 0 -2.6 -3 11/27/2005 09:50:00 9.2 1 11.8 6.5 9.2 1.1 11.8 6.5 7.5 1.1 11.8 4.9 295 7 295 165 -2.8 0 -2.6 -2.8 11/27/2005 10:00:00 7.8 1.3 10.7 3.4 7.8 1.3 10.7 3 6.6 1.4 10.7 3 294 9 294 165 -2.5 0 -2.1 -2.8 11/27/2005 10:10:00 9.4 1 11.1 5.7 9.4 1 11.5 5.7 8.4 1.5 11.8 4.2 291 7 289 165 -2.5 0 -2.1 -2.8 11/27/2005 10:20:00 9.6 1 12.2 6.8 9.7 1 12.2 6.8 9 1.3 11.5 4.9 291 8 298 165 -2.6 0.1 -2.4 -2.8 11/27/2005 10:30:00 10 1.5 13.7 6.1 10 1.5 13.7 6.1 8.4 1.5 12.2 5.3 297 9 295 165 -2.5 0 -2.1 -2.6 11/27/2005 10:40:00 8.6 1.5 12.2 5.3 8.6 1.5 12.2 5.3 7.5 1.4 11.5 4.6 298 10 263 165 -2.4 0 -2.1 -2.6 11/27/2005 10:50:00 7.2 0.9 9.1 4.9 7.1 0.9 9.5 4.9 6.4 0.8 9.1 4.6 310 12 271 165 -2 0.1 -1.7 -2.1 11/27/2005 11:00:00 6.8 0.8 8.4 4.9 6.7 0.8 8.4 4.9 6.1 0.9 8.4 3.4 312 9 317 165 -1.7 0 -1.7 -1.9 11/27/2005 11:10:00 5.7 1 8 3.4 5.7 1 8.4 3 5.2 0.7 7.2 3.4 317 12 316 165 -1.6 0.1 -1.2 -1.9 11/27/2005 11:20:00 5.5 1.1 8.8 3 5.5 1 8.8 3 5.3 1.1 9.1 3 315 17 285 165 -1.2 0.1 -0.8 -1.4 11/27/2005 11:30:00 6 1 8.8 3 6 1 8.8 3.4 4.8 1 8.4 2.6 295 10 291 165 -1.4 0.1 -1 -1.7 11/27/2005 11:40:00 6.5 0.9 9.1 3.8 6.5 0.9 9.1 4.2 5.3 0.9 8.4 2.6 299 9 291 165 -1.7 0.1 -1.2 -1.9 11/27/2005 11:50:00 5.1 1.7 8.8 1.9 5.4 1.5 8.4 2.3 4.8 1.5 8.8 1.9 280 16 285 165 -1.7 0.3 -1.2 -2.1 11/27/2005 12:00:00 1.6 0.8 3.8 0.4 1.8 0.9 3.8 0.4 1.9 1 4.6 0.4 286 38 256 165 -0.5 0.6 0.4 -1.4 11/27/2005 12:10:00 3.9 1.5 7.2 1.1 4 1.5 7.6 1.5 3.8 1.4 7.6 1.5 286 23 280 165 -0.7 0.3 0.2 -1.4 11/27/2005 12:20:00 6.3 1.1 8.8 2.6 6.5 1.1 8.8 3 6 1.4 8.8 2.3 282 8 282 165 -1.8 0.1 -1.4 -1.9 11/27/2005 12:30:00 5.9 1.5 8.8 2.6 5.9 1.5 8.8 2.6 5.5 1.6 9.5 1.5 284 9 282 165 -1.7 0 -1.4 -1.9 11/27/2005 12:40:00 5 0.6 6.5 3 5 0.6 6.8 3 4.1 0.7 6.1 2.3 294 8 295 165 -1.6 0 -1.4 -1.7 11/27/2005 12:50:00 4.7 0.8 6.8 3 4.7 0.8 6.8 3 4 0.9 6.5 2.3 294 7 293 165 -1.4 0 -1.2 -1.7 11/27/2005 13:00:00 5.8 0.9 7.6 3.8 5.9 0.9 8 3.8 4.8 1 7.2 1.9 295 7 290 165 -1.6 0 -1.4 -1.9 11/27/2005 13:10:00 7 0.6 8.4 5.3 7 0.6 8.4 4.9 5.4 0.9 7.6 3.4 301 7 292 165 -1.7 0 -1.4 -1.9 11/27/2005 13:20:00 7 0.8 8.4 4.9 7 0.8 8.4 4.9 6.2 0.9 8 3.8 309 6 311 165 -1.5 0 -1.2 -1.7 11/27/2005 13:30:00 6.9 0.5 8 5.3 6.9 0.5 8 5.3 5.1 0.5 6.8 3.8 303 3 304 165 -1.5 0 -1.4 -1.7 11/27/2005 13:40:00 5.3 1.3 8 1.9 5.3 1.2 8.4 1.9 4.9 1.2 8 1.9 315 15 300 165 -1.3 0.1 -0.8 -1.4 11/27/2005 13:50:00 4.2 0.8 6.1 1.9 4.3 0.7 6.1 1.9 3.7 0.8 5.7 1.5 294 10 289 165 -1.1 0 -0.8 -1.2 11/27/2005 14:00:00 3 1.1 4.9 0.4 3.1 1 5.3 0.4 2.7 1 5.3 0.4 299 22 291 165 -0.8 0.3 -0.1 -1.2 11/27/2005 14:10:00 3.7 0.8 5.3 1.1 3.8 0.8 5.3 1.5 3.3 0.7 5.7 1.9 299 13 293 165 -0.8 0.1 -0.3 -1 11/27/2005 14:20:00 5.6 0.6 6.8 3.8 5.7 0.6 6.8 4.2 5.1 0.9 6.8 2.6 292 8 284 165 -1.3 0.2 -0.8 -1.7 11/27/2005 14:30:00 5.4 0.5 6.8 4.2 5.5 0.5 6.8 4.2 4.2 0.7 6.1 2.6 299 5 290 165 -1.4 0 -1.2 -1.4 11/27/2005 14:40:00 5.2 0.8 6.8 3.4 5.2 0.8 6.8 2.6 4.6 0.6 6.1 3.4 318 19 304 165 -1.4 0.2 -0.8 -1.7 11/27/2005 14:50:00 3.7 0.5 4.9 2.6 3.3 0.8 4.9 1.5 3.7 0.5 4.9 2.6 347 7 349 165 -0.6 0 -0.5 -0.8 11/27/2005 15:00:00 3.5 0.4 4.9 2.6 2.9 0.8 4.9 1.1 3.6 0.4 4.9 2.6 356 15 335 165 -0.6 0 -0.5 -0.8 11/27/2005 15:10:00 2.7 0.6 4.2 1.5 2.4 0.9 4.2 0.7 2.9 0.7 4.2 0.4 347 13 355 165 -0.5 0.1 -0.3 -0.8 11/27/2005 15:20:00 2 0.7 3.8 0.4 1.9 0.7 3.8 0.4 1.9 0.8 3.8 0.4 338 29 333 165 -0.3 0 -0.1 -0.5 11/27/2005 15:30:00 0.6 0.4 1.9 0.4 0.7 0.4 1.9 0.4 0.8 0.4 1.9 0.4 321 14 312 165 -0.1 0.1 0.2 -0.5 11/27/2005 15:40:00 1.4 0.8 3.4 0.4 1.4 0.8 3.4 0.4 1.3 0.6 3.4 0.4 313 15 297 165 0 0 0.2 -0.5 11/27/2005 15:50:00 2.6 0.4 3.4 1.5 2.6 0.5 3.4 1.1 2.3 0.4 3 1.1 309 9 310 165 -1.1 0.3 -0.3 -1.4 11/27/2005 16:00:00 2.7 0.3 3.8 1.9 2.8 0.4 3.4 1.9 2.4 0.4 3.4 1.5 299 8 292 165 -1.8 0.3 -1.4 -2.6 11/27/2005 16:10:00 3 0.4 4.2 1.9 2.6 0.5 3.8 1.1 2.8 0.4 3.8 1.5 348 26 304 165 -2.9 0.3 -2.6 -3.3 11/27/2005 16:20:00 2.8 0.5 3.8 1.5 1.9 0.6 3.4 0.7 2.8 0.4 3.4 1.5 7 4 12 165 -3.4 0 -3.3 -3.5 11/27/2005 16:30:00 1.5 0.3 2.6 0.7 0.8 0.3 1.9 0.4 1.5 0.4 2.6 1.1 0 3 3 165 -3.3 0.1 -3 -3.5 11/27/2005 16:40:00 2.3 0.4 3.4 1.5 1.8 0.5 3 0.7 2.2 0.4 3 1.1 8 8 19 165 -3 0 -2.8 -3.3 11/27/2005 16:50:00 1.7 0.7 3 0.4 1.2 0.5 3 0.4 1.6 0.6 3 0.4 335 36 3 165 -3.2 0 -2.8 -3.3 11/27/2005 17:00:00 0.9 0.5 1.9 0.4 0.6 0.3 1.5 0.4 0.7 0.5 1.9 0.4 308 51 353 165 -2.9 0 -2.6 -3.3 11/27/2005 17:10:00 1.8 0.3 2.6 1.1 1.3 0.4 2.3 0.4 1.8 0.3 2.3 1.1 358 8 351 165 -2.9 0.1 -2.6 -3.3 11/27/2005 17:20:00 2.1 0.3 2.6 1.5 1.8 0.6 3 0.7 2 0.3 2.6 1.1 347 6 349 165 -3.3 0.1 -3 -3.5 11/27/2005 17:30:00 1.7 0.3 2.6 1.1 1.6 0.4 2.6 0.4 1.6 0.4 2.6 0.4 337 8 317 165 -3.1 0.1 -2.8 -3.5 11/27/2005 17:40:00 1.7 0.3 2.6 1.1 1.4 0.4 2.6 0.4 1.7 0.3 2.6 1.1 338 9 349 165 -3.2 0 -3 -3.5 11/27/2005 17:50:00 0.7 0.3 1.5 0.4 0.7 0.3 1.5 0.4 0.7 0.3 1.5 0.4 315 14 333 165 -3.2 0.1 -3 -3.5 11/27/2005 18:00:00 0.4 0 0.7 0.4 0.4 0 0.7 0.4 0.4 0.1 0.7 0.4 303 0 303 165 -3.3 0 -3 -3.5 11/27/2005 18:10:00 0.4 0.2 1.1 0.4 0.4 0.2 1.1 0.4 0.4 0.1 0.7 0.4 257 8 272 165 -3.6 0.1 -3.3 -3.7 11/27/2005 18:20:00 0.4 0.1 0.7 0.4 0.4 0.1 0.7 0.4 0.5 0.2 1.1 0.4 255 0 255 165 -3.1 0.1 -2.8 -3.5 11/27/2005 18:30:00 1 0.3 1.5 0.4 1 0.3 1.5 0.4 1 0.2 1.5 0.4 295 22 307 165 -3.3 0 -3 -3.5 11/27/2005 18:40:00 0.4 0.1 1.1 0.4 0.4 0.2 1.1 0.4 0.4 0.2 1.1 0.4 306 0 307 165 -3.4 0.1 -3 -3.5 11/27/2005 18:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 306 0 165 165 -3 0.1 -2.8 -3.3 11/27/2005 19:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 306 0 165 165 -2.9 0 -2.8 -3 11/27/2005 19:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 306 0 165 165 -3.3 0.1 -2.8 -3.5 11/27/2005 19:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 306 0 165 165 -3.4 0.1 -3 -3.5 11/27/2005 19:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0.1 0.7 0.4 306 0 165 165 -3.1 0 -2.8 -3.3 11/27/2005 19:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 306 0 165 165 -3.2 0 -3 -3.3 11/27/2005 19:50:00 0.6 0.3 1.1 0.4 0.6 0.3 1.1 0.4 0.6 0.2 1.1 0.4 237 53 208 165 -3.3 0 -3.3 -3.5 11/27/2005 20:00:00 0.5 0.2 1.1 0.4 0.5 0.2 1.1 0.4 0.5 0.2 1.1 0.4 187 0 190 165 -3.5 0.1 -3.3 -3.7 11/27/2005 20:10:00 0.4 0 0.4 0.4 0.4 0 0.7 0.4 0.4 0 0.4 0.4 187 0 165 165 -3.7 0 -3.5 -3.7 11/27/2005 20:20:00 0.4 0.2 1.1 0.4 0.5 0.2 1.1 0.4 0.5 0.2 1.1 0.4 184 6 170 165 -3.5 0 -3.3 -3.5 11/27/2005 20:30:00 0.4 0.1 1.1 0.4 0.4 0.1 1.1 0.4 0.4 0.1 1.1 0.4 170 0 170 165 -3.6 0 -3.3 -3.7 11/27/2005 20:40:00 0.4 0.2 1.1 0.4 0.4 0.1 0.7 0.4 0.4 0.2 1.1 0.4 170 0 171 165 -3.7 0 -3.5 -3.9 11/27/2005 20:50:00 0.4 0.1 1.1 0.4 0.4 0.1 0.7 0.4 0.4 0 0.7 0.4 170 0 170 165 -3.7 0.1 -3.5 -3.9 11/27/2005 21:00:00 0.4 0 0.4 0.4 0.4 0.1 0.7 0.4 0.4 0.1 0.7 0.4 183 23 165 165 -3.7 0 -3.5 -3.9 11/27/2005 21:10:00 0.9 0.3 1.5 0.4 0.9 0.3 1.5 0.4 0.8 0.3 1.5 0.4 273 28 290 165 -3.6 0.1 -3.5 -3.9 11/27/2005 21:20:00 0.6 0.3 1.5 0.4 0.7 0.3 1.5 0.4 0.6 0.3 1.1 0.4 290 0 290 165 -3.8 0 -3.5 -4.2 11/27/2005 21:30:00 0.4 0 0.4 0.4 0.4 0.1 0.7 0.4 0.6 0.2 1.1 0.4 290 0 165 165 -4.2 0 -3.9 -4.4 11/27/2005 21:40:00 0.4 0.1 0.7 0.4 0.4 0.1 0.7 0.4 0.6 0.2 1.1 0.4 290 0 290 165 -4 0 -3.7 -4.2 11/27/2005 21:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0.1 0.7 0.4 256 23 165 165 -4 0.1 -3.7 -4.4 11/27/2005 22:00:00 0.4 0.2 1.1 0.4 0.4 0.2 1.1 0.4 0.4 0.1 0.7 0.4 215 20 238 165 -4.1 0.1 -3.7 -4.4 11/27/2005 22:10:00 0.4 0.3 1.5 0.4 0.4 0.2 1.5 0.4 0.8 0.4 1.9 0.4 198 4 205 165 -3.6 0.1 -3.3 -3.9 11/27/2005 22:20:00 0.6 0.4 1.9 0.4 0.6 0.3 1.5 0.4 0.8 0.4 1.9 0.4 218 11 210 165 -3 0 -2.8 -3.3 11/27/2005 22:30:00 0.5 0.3 1.9 0.4 0.5 0.3 1.9 0.4 0.6 0.3 1.5 0.4 212 2 211 165 -3 0.1 -2.8 -3 11/27/2005 22:40:00 0.5 0.3 1.5 0.4 0.5 0.3 1.5 0.4 0.6 0.3 1.5 0.4 194 5 194 165 -3.2 0 -3 -3.3 11/27/2005 22:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 192 0 165 165 -3.2 0 -3 -3.3 11/27/2005 23:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 192 0 165 165 -3.4 0.1 -3 -3.5 11/27/2005 23:10:00 0.5 0.3 1.5 0.4 0.5 0.2 1.5 0.4 0.5 0.2 1.1 0.4 188 9 180 165 -3.5 0 -3.3 -3.5 11/27/2005 23:20:00 0.5 0.2 1.1 0.4 0.4 0.2 1.1 0.4 0.6 0.3 1.5 0.4 166 0 166 165 -3.7 0.1 -3.3 -3.9 11/27/2005 23:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0.1 0.7 0.4 166 0 165 165 -3.8 0 -3.5 -3.9 11/27/2005 23:40:00 0.4 0.1 0.7 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 166 0 166 165 -3.8 0 -3.5 -4.2 11/27/2005 23:50:00 0.6 0.2 1.1 0.4 0.5 0.2 1.1 0.4 0.4 0.1 0.7 0.4 166 0 166 165 -4 0.1 -3.7 -4.4 11/28/2005 00:00:00 0.9 0.2 1.5 0.4 0.9 0.2 1.5 0.4 0.7 0.2 1.1 0.4 169 9 166 165 -4 0.2 -3.5 -4.4 11/28/2005 00:10:00 0.9 0.2 1.5 0.4 0.7 0.3 1.5 0.4 0.7 0.2 1.1 0.4 197 0 198 165 -3.5 0 -3.5 -3.5 11/28/2005 00:20:00 1.1 0.2 1.5 0.7 1 0.2 1.5 0.4 0.9 0.2 1.5 0.4 193 3 197 165 -3.4 0.1 -3 -3.5 11/28/2005 00:30:00 1.5 0.3 2.3 0.7 1.4 0.3 1.9 0.7 1.4 0.3 1.9 0.7 191 0 191 165 -3.1 0 -2.8 -3.3 11/28/2005 00:40:00 1.3 0.3 1.9 0.7 1.1 0.3 1.5 0.4 0.9 0.3 1.5 0.4 187 3 191 165 -3.2 0 -2.8 -3.3 11/28/2005 00:50:00 0.4 0.2 1.1 0.4 0.4 0.1 0.7 0.4 0.4 0 0.4 0.4 184 0 184 165 -3.3 0 -3.3 -3.5 11/28/2005 01:00:00 0.4 0.1 1.1 0.4 0.4 0.1 1.1 0.4 0.4 0.1 0.7 0.4 201 38 282 165 -3.5 0 -3.3 -3.5 11/28/2005 01:10:00 0.4 0.1 0.7 0.4 0.4 0 0.7 0.4 0.4 0.1 0.7 0.4 274 8 269 165 -3.5 0 -3.3 -3.5 11/28/2005 01:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 266 0 165 165 -3.5 0 -3.3 -3.5 11/28/2005 01:30:00 0.4 0.2 1.1 0.4 0.4 0.1 1.1 0.4 0.4 0 0.4 0.4 266 0 266 165 -3.4 0 -3.3 -3.5 11/28/2005 01:40:00 1.1 0.4 1.9 0.4 1 0.4 1.9 0.4 1 0.3 1.5 0.4 250 8 247 165 -3 0.1 -2.8 -3.3 11/28/2005 01:50:00 0.8 0.3 1.5 0.4 0.7 0.3 1.5 0.4 0.8 0.3 1.5 0.4 235 13 247 165 -2.6 0 -2.6 -2.8 11/28/2005 02:00:00 0.7 0.3 1.1 0.4 0.6 0.3 1.1 0.4 0.5 0.2 1.1 0.4 217 0 217 165 -3.2 0.1 -2.8 -3.5 11/28/2005 02:10:00 0.5 0.2 1.1 0.4 0.4 0.1 1.1 0.4 0.7 0.3 1.1 0.4 217 0 217 165 -3.5 0 -3.3 -3.5 11/28/2005 02:20:00 0.9 0.2 1.1 0.4 0.7 0.2 1.1 0.4 0.5 0.2 1.1 0.4 217 0 217 165 -3.5 0 -3.3 -3.5 11/28/2005 02:30:00 0.4 0.2 1.1 0.4 0.4 0.2 1.1 0.4 0.5 0.2 1.1 0.4 217 0 217 165 -3.5 0 -3.3 -3.5 11/28/2005 02:40:00 0.4 0.2 0.7 0.4 0.4 0.1 0.7 0.4 0.4 0.1 0.7 0.4 217 0 217 165 -3.7 0 -3.5 -3.9 11/28/2005 02:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0.1 0.7 0.4 217 0 165 165 -3.7 0 -3.5 -3.9 11/28/2005 03:00:00 0.5 0.2 1.1 0.4 0.5 0.2 1.1 0.4 1.3 0.3 1.9 0.7 319 47 348 165 -3.9 0 -3.7 -3.9 11/28/2005 03:10:00 0.5 0.2 1.1 0.4 0.4 0.1 1.1 0.4 0.9 0.3 1.5 0.4 337 9 330 165 -3.7 0 -3.5 -3.7 11/28/2005 03:20:00 0.8 0.4 1.9 0.4 0.6 0.3 1.5 0.4 1.4 0.5 2.3 0.7 354 6 6 165 -3.7 0 -3.5 -3.7 11/28/2005 03:30:00 0.5 0.3 1.5 0.4 0.4 0.2 1.1 0.4 1 0.5 2.3 0.4 6 0 6 165 -3.7 0 -3.5 -3.9 11/28/2005 03:40:00 0.4 0.1 0.7 0.4 0.4 0 0.7 0.4 0.4 0 0.4 0.4 6 0 6 165 -3.7 0 -3.5 -3.7 11/28/2005 03:50:00 0.4 0.2 1.1 0.4 0.4 0.2 1.1 0.4 0.4 0.1 0.7 0.4 3 11 351 165 -3.7 0 -3.5 -3.9 11/28/2005 04:00:00 0.7 0.3 1.1 0.4 0.6 0.3 1.1 0.4 0.5 0.2 1.1 0.4 277 45 322 165 -3.5 0 -3.3 -3.7 11/28/2005 04:10:00 0.4 0.2 0.7 0.4 0.4 0.2 0.7 0.4 0.4 0.1 0.7 0.4 230 0 230 165 -3.2 0 -3 -3.5 11/28/2005 04:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0.1 0.7 0.4 230 0 165 165 -3.8 0 -3.3 -3.9 11/28/2005 04:30:00 0.6 0.3 1.1 0.4 0.5 0.2 1.1 0.4 0.7 0.3 1.1 0.4 222 7 230 165 -3.5 0 -3.3 -3.7 11/28/2005 04:40:00 0.4 0 0.7 0.4 0.4 0 0.4 0.4 0.4 0.1 0.7 0.4 217 0 217 165 -3.5 0.1 -3.3 -3.5 11/28/2005 04:50:00 0.4 0.2 1.1 0.4 0.4 0.1 1.1 0.4 0.4 0.2 1.1 0.4 208 13 187 165 -3.5 0 -3.3 -3.5 11/28/2005 05:00:00 0.8 0.5 1.5 0.4 0.7 0.4 1.5 0.4 0.7 0.4 1.5 0.4 179 11 169 165 -3.5 0 -3.3 -3.5 11/28/2005 05:10:00 1.2 0.2 1.5 0.7 1.1 0.2 1.5 0.7 1 0.2 1.5 0.7 161 0 162 165 -3.5 0.1 -3.3 -3.5 11/28/2005 05:20:00 0.6 0.4 1.5 0.4 0.6 0.3 1.5 0.4 0.6 0.4 1.5 0.4 161 0 162 165 -3.6 0 -3.5 -3.5 11/28/2005 05:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 161 0 165 165 -3.3 0 -3.3 -3.5 11/28/2005 05:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0.1 0.7 0.4 161 0 165 165 -3.5 0 -3.3 -3.5 11/28/2005 05:50:00 0.6 0.3 1.1 0.4 0.5 0.2 1.5 0.4 0.9 0.3 1.5 0.4 112 79 162 165 -3.7 0 -3.5 -3.7 11/28/2005 06:00:00 0.8 0.4 1.5 0.4 0.7 0.4 1.5 0.4 1.2 0.2 1.9 0.7 358 11 7 165 -3.3 0.1 -3.3 -3.5 11/28/2005 06:10:00 0.6 0.2 1.1 0.4 0.5 0.2 1.1 0.4 1.1 0.3 1.5 0.7 341 0 341 165 -3.2 0 -3 -3.3 11/28/2005 06:20:00 0.4 0.1 0.7 0.4 0.4 0.1 0.7 0.4 0.4 0.1 0.7 0.4 341 0 341 165 -3.2 0 -2.8 -3.3 11/28/2005 06:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0.1 1.1 0.4 328 29 165 165 -3 0 -2.8 -3 11/28/2005 06:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 264 0 165 165 -3 0 -2.8 -3 11/28/2005 06:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 264 0 165 165 -2.9 0 -2.8 -3 11/28/2005 07:00:00 0.5 0.3 1.5 0.4 0.5 0.3 1.5 0.4 0.9 0.4 1.5 0.4 133 76 89 165 -2.8 0 -2.6 -2.8 11/28/2005 07:10:00 1 0.3 1.5 0.4 0.9 0.3 1.5 0.4 1 0.2 1.5 0.4 108 21 110 165 -2.8 0 -2.6 -2.8 11/28/2005 07:20:00 0.5 0.3 1.1 0.4 0.5 0.2 1.1 0.4 0.6 0.3 1.5 0.4 159 0 157 165 -2.8 0 -2.6 -2.8 11/28/2005 07:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 159 0 165 165 -2.9 0 -2.8 -3 11/28/2005 07:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0.1 0.7 0.4 159 0 165 165 -2.6 0.1 -2.6 -2.8 11/28/2005 07:50:00 0.4 0.1 1.1 0.4 0.4 0.1 1.1 0.4 0.5 0.3 1.5 0.4 150 14 143 165 -2.5 0 -2.4 -2.6 11/28/2005 08:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.7 0.3 1.1 0.4 129 0 165 165 -2.5 0 -2.4 -2.6 11/28/2005 08:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 129 0 165 165 -2.5 0 -2.1 -2.6 11/28/2005 08:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 129 0 165 165 -2.5 0 -2.1 -2.6 11/28/2005 08:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 129 0 165 165 -2.5 0 -2.4 -2.6 11/28/2005 08:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 129 0 165 165 -2.4 0 -2.1 -2.6 11/28/2005 08:50:00 0.5 0.2 1.1 0.4 0.4 0 0.7 0.4 0.6 0.3 1.1 0.4 94 36 56 165 -2.4 0 -2.1 -2.6 11/28/2005 09:00:00 0.5 0.2 1.1 0.4 0.4 0.2 1.1 0.4 0.8 0.2 1.1 0.4 6 7 56 165 -2.5 0 -2.4 -2.6 11/28/2005 09:10:00 0.4 0.1 0.7 0.4 0.4 0.1 1.1 0.4 0.5 0.2 1.1 0.4 54 18 61 165 -2.3 0 -2.1 -2.6 11/28/2005 09:20:00 0.4 0 0.4 0.4 0.4 0.1 0.7 0.4 0.6 0.2 1.1 0.4 61 0 165 165 -2.2 0 -2.1 -2.4 11/28/2005 09:30:00 0.4 0.2 1.1 0.4 0.5 0.2 1.1 0.4 0.7 0.2 1.1 0.4 61 0 61 165 -2.2 0 -2.1 -2.4 11/28/2005 09:40:00 0.4 0.1 1.1 0.4 0.4 0.1 1.1 0.4 0.4 0.2 0.7 0.4 61 0 61 165 -2.1 0 -2.1 -2.1 11/28/2005 09:50:00 0.6 0.3 1.1 0.4 0.6 0.3 1.1 0.4 0.7 0.3 1.1 0.4 76 8 61 165 -2.1 0 -1.9 -2.1 11/28/2005 10:00:00 0.4 0.2 1.1 0.4 0.4 0.2 1.1 0.4 0.5 0.3 1.5 0.4 80 0 80 165 -2.1 0 -1.9 -2.1 11/28/2005 10:10:00 0.7 0.4 1.9 0.4 0.8 0.4 1.9 0.4 0.7 0.5 1.9 0.4 70 10 56 165 -2.1 0 -1.9 -2.1 11/28/2005 10:20:00 1.4 0.4 2.3 0.4 1.3 0.4 2.3 0.4 1.7 0.3 2.3 0.7 51 2 48 165 -2.1 0 -1.9 -2.1 11/28/2005 10:30:00 0.6 0.4 1.9 0.4 0.6 0.4 1.5 0.4 1 0.4 1.9 0.4 52 0 52 165 -2 0 -1.9 -2.1 11/28/2005 10:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0.2 1.1 0.4 52 0 165 165 -2 0 -1.9 -2.1 11/28/2005 10:50:00 0.4 0.1 0.7 0.4 0.4 0 0.7 0.4 0.4 0.1 1.1 0.4 52 0 52 165 -2 0 -1.9 -1.9 11/28/2005 11:00:00 0.5 0.2 1.1 0.4 0.4 0.2 1.1 0.4 0.6 0.2 1.1 0.4 63 15 52 165 -2 0 -1.9 -2.1 11/28/2005 11:10:00 0.4 0.1 0.7 0.4 0.4 0.1 0.7 0.4 0.4 0.2 0.7 0.4 84 0 84 165 -2 0 -1.9 -2.1 11/28/2005 11:20:00 0.6 0.2 1.1 0.4 0.4 0.1 1.1 0.4 0.6 0.2 1.1 0.4 124 24 132 165 -2 0 -1.9 -2.1 11/28/2005 11:30:00 0.4 0.1 1.1 0.4 0.4 0.1 0.7 0.4 0.4 0.1 0.7 0.4 140 2 142 165 -1.9 0 -1.9 -1.9 11/28/2005 11:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 142 0 165 165 -1.7 0 -1.4 -1.9 11/28/2005 11:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 142 0 165 165 -1.4 0 -1.2 -1.7 11/28/2005 12:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 142 0 165 165 -1.2 0 -1 -1.4 11/28/2005 12:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 142 0 165 165 -1 0 -0.8 -1.2 11/28/2005 12:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 123 33 165 165 -1 0 -0.8 -1.2 11/28/2005 12:30:00 0.4 0.1 1.1 0.4 0.4 0 0.7 0.4 0.5 0.2 1.1 0.4 32 24 14 165 -0.9 0 -0.8 -1 11/28/2005 12:40:00 0.5 0.2 1.1 0.4 0.4 0.1 0.7 0.4 0.8 0.2 1.5 0.4 13 0 14 165 -0.9 0 -0.8 -1 11/28/2005 12:50:00 0.5 0.2 1.1 0.4 0.4 0.1 0.7 0.4 0.9 0.2 1.5 0.4 13 0 14 165 -0.9 0 -0.8 -1.2 11/28/2005 13:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.5 0.2 0.7 0.4 13 0 165 165 -1 0 -0.8 -1.2 11/28/2005 13:10:00 0.4 0.1 0.7 0.4 0.4 0.1 0.7 0.4 0.4 0.1 1.1 0.4 14 0 14 165 -0.9 0 -0.5 -1 11/28/2005 13:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 13 0 165 165 -0.6 0 -0.5 -0.8 11/28/2005 13:30:00 0.9 0.5 1.9 0.4 0.8 0.4 1.5 0.4 1 0.5 2.3 0.4 349 19 336 165 -0.6 0.1 -0.5 -0.8 11/28/2005 13:40:00 1.1 0.2 1.5 0.4 0.7 0.3 1.5 0.4 1.4 0.2 2.3 0.7 2 7 350 165 -1 0 -0.8 -1.2 11/28/2005 13:50:00 0.9 0.3 1.5 0.4 0.6 0.3 1.5 0.4 0.9 0.4 1.5 0.4 9 3 5 165 -1 0 -0.8 -1.2 11/28/2005 14:00:00 0.7 0.3 1.5 0.4 0.4 0.2 1.1 0.4 0.9 0.3 1.5 0.4 11 0 11 165 -1 0 -0.8 -1.2 11/28/2005 14:10:00 1 0.3 1.5 0.4 0.7 0.3 1.5 0.4 1.1 0.3 1.9 0.4 358 15 351 165 -1 0 -0.8 -1.2 11/28/2005 14:20:00 1.3 0.3 1.9 0.7 1.2 0.3 1.9 0.4 1.5 0.2 1.9 0.7 20 3 11 165 -1.2 0 -1 -1.2 11/28/2005 14:30:00 1.5 0.3 1.9 0.4 1.2 0.4 1.9 0.4 1.5 0.3 2.3 0.7 11 10 23 165 -1.2 0 -1.2 -1.2 11/28/2005 14:40:00 1.3 0.3 1.9 0.4 0.9 0.4 1.9 0.4 1.2 0.3 1.9 0.4 2 8 1 165 -1.3 0 -1.2 -1.4 11/28/2005 14:50:00 1.5 0.2 2.3 1.1 1.1 0.4 1.9 0.4 1.5 0.3 2.3 0.7 351 9 0 165 -1.4 0 -1.4 -1.4 11/28/2005 15:00:00 1.7 0.3 2.3 1.1 1.2 0.5 2.3 0.4 1.8 0.3 2.3 1.1 358 12 10 165 -1.4 0 -1.4 -1.4 11/28/2005 15:10:00 1 0.5 1.9 0.4 0.8 0.5 1.9 0.4 1.2 0.4 2.3 0.4 347 10 347 165 -1.4 0 -1.2 -1.4 11/28/2005 15:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.7 0.4 2 0 165 165 -1.6 0 -1.4 -1.7 11/28/2005 15:30:00 0.4 0 0.4 0.4 0.4 0 0.7 0.4 0.4 0 0.4 0.4 2 0 165 165 -1.6 0 -1.4 -1.7 11/28/2005 15:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 2 0 165 165 -1.6 0 -1.4 -1.7 11/28/2005 15:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0.1 0.7 0.4 2 0 165 165 -1.6 0 -1.4 -1.7 11/28/2005 16:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 2 0 165 165 -1.6 0 -1.4 -1.4 11/28/2005 16:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 2 0 165 165 -1.6 0 -1.4 -1.7 11/28/2005 16:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 2 0 165 165 -1.6 0 -1.4 -1.7 11/28/2005 16:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 2 0 165 165 -1.7 0 -1.4 -1.7 11/28/2005 16:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 2 0 165 165 -1.6 0 -1.4 -1.7 11/28/2005 16:50:00 0.4 0 0.7 0.4 0.4 0.1 1.1 0.4 0.4 0 0.7 0.4 315 47 268 165 -1.6 0 -1.4 -1.7 11/28/2005 17:00:00 0.6 0.3 1.1 0.4 0.5 0.3 1.5 0.4 0.4 0.2 1.1 0.4 267 0 268 165 -1.6 0 -1.4 -1.7 11/28/2005 17:10:00 1.1 0.3 1.5 0.4 1 0.3 1.5 0.4 0.9 0.2 1.5 0.4 294 12 268 165 -1.6 0 -1.4 -1.7 11/28/2005 17:20:00 1.5 0.3 2.3 1.1 1.5 0.3 2.3 1.1 1.3 0.2 1.9 0.7 311 2 309 165 -1.7 0 -1.4 -1.9 11/28/2005 17:30:00 2.1 0.4 3 1.5 2 0.4 3 1.1 1.8 0.4 3 1.1 312 5 316 165 -1.7 0 -1.7 -2.1 11/28/2005 17:40:00 1.8 0.3 2.6 1.5 1.7 0.3 2.6 1.1 1.7 0.2 2.6 1.1 312 9 313 165 -1.6 0 -1.4 -1.7 11/28/2005 17:50:00 1 0.4 1.9 0.4 0.9 0.4 1.9 0.4 1.2 0.3 1.9 0.4 329 0 329 165 -1.7 0 -1.4 -1.9 11/28/2005 18:00:00 0.4 0.1 1.1 0.4 0.4 0.1 1.1 0.4 0.5 0.2 1.1 0.4 329 0 329 165 -1.7 0 -1.4 -1.9 11/28/2005 18:10:00 0.4 0.2 1.5 0.4 0.4 0.2 1.5 0.4 0.4 0.2 1.5 0.4 301 32 263 165 -1.6 0 -1.4 -1.7 11/28/2005 18:20:00 0.4 0.1 0.7 0.4 0.4 0.1 1.1 0.4 0.4 0.1 1.1 0.4 263 0 263 165 -1.6 0 -1.4 -1.7 11/28/2005 18:30:00 0.8 0.4 1.5 0.4 0.8 0.4 1.5 0.4 0.5 0.2 1.1 0.4 268 17 282 165 -1.6 0 -1.4 -1.7 11/28/2005 18:40:00 1.1 0.4 1.9 0.4 1 0.4 1.9 0.4 0.9 0.4 1.9 0.4 302 6 298 165 -1.7 0 -1.4 -1.9 11/28/2005 18:50:00 2 0.4 2.6 0.7 1.9 0.4 2.6 0.7 1.9 0.5 2.6 0.7 325 9 332 165 -1.7 0 -1.7 -1.9 11/28/2005 19:00:00 2.5 0.4 3.4 1.5 2.3 0.4 3.4 1.1 2.3 0.4 3.4 1.5 330 8 329 165 -2 0 -1.9 -2.1 11/28/2005 19:10:00 2.4 0.5 3.8 1.5 2.3 0.5 3.8 1.1 2.2 0.4 3.4 1.5 319 13 299 165 -2.1 0 -1.9 -2.1 11/28/2005 19:20:00 4.3 0.8 5.7 2.6 4.2 0.8 5.7 2.6 3.9 0.9 5.3 2.3 314 5 313 165 -2.1 0 -1.9 -2.1 11/28/2005 19:30:00 5.5 0.5 6.8 4.2 5.4 0.5 6.5 4.2 5.3 0.5 6.5 3.8 319 5 315 165 -2 0 -1.9 -2.1 11/28/2005 19:40:00 4.6 0.7 6.1 3 4.5 0.7 6.1 3 4.3 0.7 6.1 2.6 313 8 316 165 -1.7 0.1 -1.4 -2.1 11/28/2005 19:50:00 4.3 0.4 5.3 3 4.2 0.4 5.3 3.4 3.9 0.4 4.9 2.6 311 7 304 165 -1.7 0 -1.7 -1.9 11/28/2005 20:00:00 4.8 0.8 6.5 3.4 4.8 0.8 6.5 3.4 3.9 0.6 5.7 2.3 304 6 298 165 -1.9 0.1 -1.4 -2.1 11/28/2005 20:10:00 5.4 0.6 6.8 3.4 5.4 0.6 6.8 3.4 4.7 0.6 6.5 3 287 7 295 165 -1.3 0.2 -0.8 -1.4 11/28/2005 20:20:00 1.5 0.8 4.2 0.4 1.7 0.8 4.2 0.4 1.5 1 4.2 0.4 272 26 283 165 -1.1 0 -0.8 -1.4 11/28/2005 20:30:00 1.2 0.9 3.8 0.4 1.1 0.9 3.8 0.4 0.6 0.4 2.3 0.4 294 45 286 165 -1.5 0 -1.2 -1.7 11/28/2005 20:40:00 1.7 0.8 3.8 0.4 1.5 0.8 3.8 0.4 1.1 0.6 2.6 0.4 306 27 296 165 -1.6 0 -1.4 -1.7 11/28/2005 20:50:00 2.8 0.9 4.9 0.4 2.9 1 4.9 0.4 1.9 0.8 4.6 0.4 273 18 278 165 -1.6 0 -1.4 -1.7 11/28/2005 21:00:00 2.4 1.5 6.5 0.4 2.6 1.7 6.5 0.4 2.2 1.5 6.1 0.4 232 56 280 165 -1.4 0.1 -1.2 -1.7 11/28/2005 21:10:00 2.5 1.5 8 0.4 2.6 1.7 8 0.4 1.9 1.3 6.5 0.4 245 41 273 165 -1.7 0 -1.4 -1.9 11/28/2005 21:20:00 6 0.8 8.4 4.2 6 0.9 8.4 4.2 5.1 1.1 8.4 3 295 11 315 165 -0.6 0.3 -0.3 -1.4 11/28/2005 21:30:00 5.5 0.9 8.4 3.4 5.5 0.9 8.4 3.4 4.7 0.9 7.2 3 302 12 304 165 -0.3 0.1 -0.1 -0.8 11/28/2005 21:40:00 4.5 0.8 7.2 3 4.5 0.8 6.8 3 3.9 0.8 6.8 2.3 310 15 307 165 -0.3 0 -0.3 -0.5 11/28/2005 21:50:00 2.6 1.2 6.5 0.4 2.7 1.2 6.5 0.4 2.6 0.8 5.3 1.1 302 35 307 165 0.1 0.2 0.4 -0.5 11/28/2005 22:00:00 3.4 1 6.1 0.4 3.5 1 6.1 0.7 3.2 0.8 5.3 1.9 284 21 321 165 0.2 0.1 0.7 -0.1 11/28/2005 22:10:00 2.9 1.2 5.7 0.4 3 1.3 6.1 0.4 2.7 1.1 6.1 0.4 272 22 309 165 0.2 0.1 0.7 -0.1 11/28/2005 22:20:00 4.4 0.9 6.1 1.5 4.4 0.8 6.5 2.3 4.1 0.9 6.5 1.5 287 11 287 165 0.1 0 0.2 -0.1 11/28/2005 22:30:00 5.2 0.8 7.2 3 5.1 0.8 7.2 3 4.4 0.9 6.5 2.3 289 10 310 165 -0.1 0 0.2 -0.3 11/28/2005 22:40:00 5.8 0.8 7.6 3.8 5.8 0.7 7.2 3.8 5.2 1 7.6 3 284 8 291 165 -0.1 0 0.2 -0.1 11/28/2005 22:50:00 5.9 0.8 7.6 3.8 5.8 0.8 7.6 3.8 4.8 0.9 7.2 2.6 293 7 301 165 -0.1 0 0.2 -0.1 11/28/2005 23:00:00 5.5 0.9 7.6 3.4 5.5 0.9 8 3.4 5 1.1 7.6 2.6 287 9 277 165 0 0.1 0.4 -0.3 11/28/2005 23:10:00 4.4 1 6.8 2.3 4.3 1 7.2 1.9 3.7 0.9 6.5 1.1 295 11 301 165 0 0.1 0.2 -0.3 11/28/2005 23:20:00 5.4 0.9 7.2 3 5.3 0.9 7.2 2.6 4.5 0.8 6.8 2.6 299 11 287 165 0.2 0 0.7 -0.1 11/28/2005 23:30:00 6.3 0.9 8.4 3.8 6.2 0.9 8 3.8 5 0.9 7.6 3 295 7 293 165 0.1 0 0.7 -0.1 11/28/2005 23:40:00 6.9 1.1 9.1 3.4 6.7 1.1 9.1 3 5.6 1 9.1 2.3 302 11 285 165 -0.5 0 -0.1 -0.8 11/28/2005 23:50:00 4.5 0.8 7.6 1.9 4.4 0.8 7.2 1.9 3.8 0.6 5.7 2.3 306 12 289 165 -1 0 -0.5 -1.2 11/29/2005 00:00:00 5.9 1.7 9.9 2.6 5.9 1.7 9.9 2.6 4.9 1.5 8.8 1.5 300 9 302 165 -1 0 -0.8 -1.2 11/29/2005 00:10:00 8.5 1.3 12.2 6.1 8.4 1.2 12.2 5.7 7.1 1 10.7 4.6 307 7 294 165 -0.9 0 -0.8 -1 11/29/2005 00:20:00 7.8 1.2 11.1 5.3 7.8 1.2 10.7 4.6 6.6 1.1 9.9 4.2 306 8 305 165 -0.9 0 -0.8 -1.2 11/29/2005 00:30:00 9.9 1.5 13.7 6.5 9.9 1.5 13.3 6.5 7.9 1.4 12.6 4.9 304 6 313 165 -0.9 0 -0.8 -1 11/29/2005 00:40:00 10.2 1.5 13.7 7.2 10.1 1.5 13.3 7.2 8.9 1.7 13.3 5.3 310 7 313 165 -1 0 -0.8 -1.2 11/29/2005 00:50:00 9.5 2.2 13 5.3 9.4 2.2 13 5.3 8.9 2.3 12.6 4.2 316 9 313 165 -0.9 0 -0.8 -1.2 11/29/2005 01:00:00 6.7 1 9.9 4.6 6.7 1 9.9 4.6 5.7 1.2 9.1 3.4 303 10 298 165 -0.8 0 -0.5 -1.2 11/29/2005 01:10:00 8.2 0.8 9.9 6.5 8.2 0.8 9.5 6.5 6.6 1 8.8 4.6 294 6 299 165 -0.6 0.1 -0.3 -0.8 11/29/2005 01:20:00 9.2 1.2 12.6 6.1 9.1 1.2 13 6.5 7.1 1.2 11.8 4.6 301 6 306 165 -0.8 0 -0.8 -0.8 11/29/2005 01:30:00 12.5 1.3 16.1 9.5 12.5 1.2 16.1 9.1 11 1.4 14.9 7.2 311 5 305 165 -0.8 0 -0.5 -1 11/29/2005 01:40:00 14.4 1.5 17.2 10.3 14.3 1.5 17.2 10.3 13.2 1.7 16.8 7.6 312 5 310 165 -0.5 0.1 -0.3 -0.8 11/29/2005 01:50:00 14.1 1.3 17.2 10.7 14.1 1.3 17.2 10.3 10.7 1.8 16.1 6.1 304 5 307 165 -0.5 0 -0.3 -0.8 11/29/2005 02:00:00 12.1 1.7 16.1 7.6 12.1 1.7 15.6 7.2 9.1 1.5 12.6 5.3 297 7 300 165 -0.5 0 -0.3 -0.5 11/29/2005 02:10:00 12.1 1.2 14.9 9.1 12.1 1.2 15.3 8.8 10.3 1.7 15.6 6.5 290 8 285 165 -0.4 0 -0.3 -0.5 11/29/2005 02:20:00 11.9 1.1 14.9 8.8 11.9 1.1 14.5 8.4 9.4 1.2 13.7 6.5 297 6 295 165 -0.3 0 -0.1 -0.3 11/29/2005 02:30:00 11.2 1.6 15.6 7.6 11.1 1.6 15.3 7.2 9 1.6 14.1 5.7 302 8 304 165 -0.2 0 -0.1 -0.3 11/29/2005 02:40:00 11.8 1.3 15.3 8.4 11.7 1.3 15.6 8.4 9.7 1.6 14.1 6.5 305 7 307 165 -0.2 0 -0.1 -0.3 11/29/2005 02:50:00 11.4 1.3 15.3 7.6 11.3 1.3 14.9 7.6 10.3 1.6 14.5 6.5 310 7 308 165 0.1 0 0.2 -0.1 11/29/2005 03:00:00 12.2 1.6 16.1 8.8 12 1.5 15.6 8.8 9.7 1.5 13 6.1 303 6 307 165 0.2 0 0.7 -0.1 11/29/2005 03:10:00 12.3 1.2 15.3 8.4 12.1 1.2 14.9 8.8 9.7 1.2 13 6.8 299 6 304 165 0.5 0 0.7 0.2 11/29/2005 03:20:00 10.8 1.4 14.1 7.2 10.7 1.3 13.7 7.2 8.8 1.5 12.2 4.2 298 7 299 165 0.7 0 0.9 0.7 11/29/2005 03:30:00 9.3 1.5 13.3 4.6 9.2 1.5 13 4.9 7.3 1.8 11.8 1.9 295 9 295 165 0.7 0 0.9 0.7 11/29/2005 03:40:00 9.3 1.2 12.2 6.8 9.2 1.1 12.2 6.8 7.8 1.5 11.5 4.2 293 9 310 165 0.8 0 0.9 0.7 11/29/2005 03:50:00 8.8 1 11.5 6.5 8.8 1 11.8 6.5 7.3 1.1 10.3 4.2 293 8 290 165 1 0 1.4 0.9 11/29/2005 04:00:00 9.7 0.8 12.2 7.2 9.7 0.8 11.8 6.8 7.8 1 11.5 4.9 294 6 302 165 1.2 0 1.4 1.1 11/29/2005 04:10:00 9.1 0.9 11.5 6.8 9 0.9 11.1 6.8 7.1 1 9.9 4.6 295 6 302 165 1.3 0 1.6 1.1 11/29/2005 04:20:00 9.4 1 12.2 6.1 9.3 1.1 12.6 6.1 7.8 1.4 11.5 4.9 290 6 291 165 1.7 0 1.8 1.4 11/29/2005 04:30:00 8.8 0.8 11.8 6.8 8.8 0.8 11.8 6.8 7.9 0.9 9.9 5.3 287 5 287 165 1.8 0 1.8 1.6 11/29/2005 04:40:00 8.2 0.7 9.9 6.1 8.3 0.7 10.3 6.5 7.8 0.9 9.9 5.3 283 5 284 165 1.4 0.1 1.8 1.4 11/29/2005 04:50:00 9.1 0.9 10.7 6.5 9.1 0.9 11.1 6.5 8.6 1.1 10.7 5.7 284 6 284 165 1.7 0.2 1.8 1.4 11/29/2005 05:00:00 8.6 0.8 10.7 6.1 8.6 0.8 10.7 6.1 7.9 1 10.3 5.3 284 6 295 165 1.8 0 1.8 1.8 11/29/2005 05:10:00 8.9 0.8 11.5 6.5 8.8 0.8 11.5 6.8 7.7 1 10.3 4.9 289 6 295 165 2 0 2.3 1.8 11/29/2005 05:20:00 8.9 1 11.1 5.7 8.8 1 11.5 5.7 8.1 1.2 12.6 4.9 287 6 284 165 2.2 0 2.3 2.1 11/29/2005 05:30:00 8.8 0.9 11.8 6.1 8.8 1 11.8 6.5 8.2 1.1 11.1 5.3 283 5 289 165 2.3 0 2.6 2.3 11/29/2005 05:40:00 8 0.9 9.9 5.3 8 0.9 10.3 5.3 7.2 1.1 9.9 4.6 284 6 285 165 2.3 0 2.6 2.3 11/29/2005 05:50:00 8.1 1.1 11.5 4.6 8.1 1.1 11.5 4.6 7.3 1.3 10.7 4.2 286 8 283 165 2.1 0 2.3 1.8 11/29/2005 06:00:00 8.2 1.1 11.1 4.9 8.2 1.1 11.1 5.3 7 1.4 11.5 4.2 290 9 287 165 2 0.1 2.3 1.8 11/29/2005 06:10:00 8.6 1.1 11.5 5.7 8.7 1 11.5 6.1 7.8 1.3 10.7 4.6 282 7 286 165 1.9 0 2.1 1.8 11/29/2005 06:20:00 6.7 1.3 10.7 3.8 7.1 1.2 10.3 4.2 6.6 1.3 10.7 4.2 276 12 278 165 1.8 0 1.8 1.8 11/29/2005 06:30:00 5.3 2.1 11.5 1.9 5.4 2 11.5 1.9 4.9 1.8 10.7 1.5 284 13 282 165 1.8 0 1.8 1.6 11/29/2005 06:40:00 2.9 1.2 6.8 0.4 3.1 1.3 6.8 0.4 3 1.2 7.6 0.4 272 22 312 165 1.4 0.1 1.6 1.4 11/29/2005 06:50:00 5.1 1 8.8 3 5.2 1 8.4 2.6 4.7 1 8 2.3 288 16 310 165 1.5 0 1.8 1.4 11/29/2005 07:00:00 5.7 1 8.8 3.8 5.7 1 8 3.4 5.1 1 8 2.6 289 12 292 165 1.5 0 1.6 1.4 11/29/2005 07:10:00 6.7 1.5 11.5 3.8 6.6 1.5 11.1 3.8 6.2 1.2 9.5 2.6 316 10 302 165 1.4 0 1.6 1.4 11/29/2005 07:20:00 10.3 1.3 13.3 7.2 10.2 1.3 13.3 7.2 8.6 1.4 12.2 4.6 305 9 287 165 1.7 0.1 1.8 1.4 11/29/2005 07:30:00 11.1 1.1 14.5 8 11.1 1.1 14.1 8 9.4 1.3 13.3 6.5 305 8 310 165 1.8 0 1.8 1.6 11/29/2005 07:40:00 11 1.5 15.3 7.2 11 1.5 15.3 7.2 9.1 1.5 13 5.3 305 8 305 165 1.7 0 1.8 1.6 11/29/2005 07:50:00 10.5 1.8 16.8 6.8 10.5 1.8 16.4 6.8 9 1.7 14.5 4.9 301 11 295 165 1.6 0 1.8 1.4 11/29/2005 08:00:00 12.4 1.8 16.4 8 12.4 1.8 16.4 8 10.3 2 15.3 6.1 303 8 301 165 1.5 0 1.6 1.4 11/29/2005 08:10:00 15.1 1.5 18.3 10.7 15 1.5 18.7 11.1 12.8 2 17.9 8 308 5 309 165 1.5 0 1.6 1.4 11/29/2005 08:20:00 15.5 1.8 19.9 11.5 15.4 1.8 19.9 11.1 11.8 1.6 16.8 8.4 301 6 304 165 1.4 0 1.6 1.4 11/29/2005 08:30:00 15.8 1.9 21.4 9.9 15.8 2 21.4 10.3 12 1.8 16.8 8.4 304 5 299 165 1.4 0 1.6 1.4 11/29/2005 08:40:00 17.3 1.3 21.4 12.6 17.3 1.3 21 12.2 13.1 1.7 19.5 9.1 302 5 307 165 1.4 0 1.6 1.4 11/29/2005 08:50:00 16.1 1.5 19.9 11.8 16 1.6 19.5 11.5 13 1.7 17.9 8 304 7 297 165 1.4 0 1.4 1.4 11/29/2005 09:00:00 16.1 1.5 20.2 12.6 16 1.5 19.9 12.6 14.3 2 20.6 9.9 308 7 314 165 1.3 0 1.4 1.4 11/29/2005 09:10:00 17.3 2.1 21.8 11.8 17.2 2.1 21.4 11.8 14.4 2.3 21.4 8.4 306 6 301 165 1.4 0 1.4 1.4 11/29/2005 09:20:00 16.9 1.7 21 13.3 16.9 1.7 20.6 13.3 14.1 1.7 19.9 9.1 304 7 292 165 1.3 0 1.4 1.1 11/29/2005 09:30:00 17.3 1.4 21 13 17.2 1.4 21 13 15.5 1.7 19.5 10.3 310 7 300 165 1.3 0 1.4 1.4 11/29/2005 09:40:00 17 1.5 20.6 11.5 16.9 1.5 20.2 11.8 15.5 1.6 20.6 11.1 312 6 304 165 1.2 0 1.4 1.1 11/29/2005 09:50:00 16.7 1.3 19.9 12.6 16.7 1.3 19.9 13 16.5 1.6 21.4 12.2 317 6 316 165 1.1 0 1.4 0.9 11/29/2005 10:00:00 17.3 1.4 21 14.1 17.2 1.4 21 14.1 16.9 1.6 21.4 12.6 318 6 321 165 1 0 1.1 0.9 11/29/2005 10:10:00 17.7 1.7 22.6 12.2 17.6 1.7 21.8 13 17.2 1.7 21.8 12.2 317 6 313 165 0.9 0 1.4 0.9 11/29/2005 10:20:00 18.3 1.5 22.1 14.1 18.2 1.5 21.8 14.5 17.6 1.5 23.3 14.1 316 5 311 165 1.1 0 1.4 0.9 11/29/2005 10:30:00 18.1 1.7 22.6 13.7 18 1.7 22.1 13.7 17.4 1.7 21.4 12.6 317 6 319 165 1.2 0 1.6 1.1 11/29/2005 10:40:00 19.1 1.5 22.6 13.3 18.9 1.5 22.1 13 18.4 1.8 22.1 13.3 317 6 312 165 1.4 0 1.6 1.4 11/29/2005 10:50:00 17 2 21.8 12.2 16.9 2 21.8 12.2 16.4 2 21.4 11.5 320 8 307 165 1.2 0 1.4 1.1 11/29/2005 11:00:00 16.2 1.9 20.2 11.8 16.1 2 19.9 11.8 15.7 2 21.4 11.8 321 10 310 165 1.3 0 1.4 1.4 11/29/2005 11:10:00 15.6 1.8 21.4 10.3 15.5 1.8 20.6 9.9 14.9 1.7 20.6 11.1 321 10 296 165 1.2 0 1.4 1.1 11/29/2005 11:20:00 16.4 2.4 22.9 10.7 16.3 2.5 22.9 11.1 15.8 2.3 22.1 10.3 318 9 310 165 1.1 0 1.4 0.9 11/29/2005 11:30:00 19.2 1.7 22.9 14.5 19.1 1.7 22.9 14.1 18.4 1.9 23.3 11.5 315 6 312 165 1.2 0 1.4 1.1 11/29/2005 11:40:00 19 1.6 24.8 13.7 18.8 1.7 24.4 14.1 18.6 1.7 22.9 13.3 320 7 329 165 1.2 0 1.4 1.1 11/29/2005 11:50:00 18.1 1.6 22.1 13.7 18 1.6 21.8 13.7 17.3 1.7 21 11.8 318 9 300 165 1.1 0 1.4 0.9 11/29/2005 12:00:00 17.4 1.9 22.9 13.3 17.3 1.8 22.6 13.3 17.2 2.1 22.9 11.1 325 10 321 165 1.5 0 1.8 1.1 11/29/2005 12:10:00 18.9 2.4 25.2 11.5 18.8 2.3 25.2 11.1 18.4 2.4 24.4 11.5 325 10 321 165 1.5 0 1.8 1.4 11/29/2005 12:20:00 20.6 2.6 26.8 13 20.5 2.6 26.8 14.1 20.5 2.7 26.8 14.5 324 8 314 165 2.1 0 2.3 1.8 11/29/2005 12:30:00 18.2 1.7 22.9 13.7 18.1 1.7 22.6 13.3 17.4 1.9 21.8 13 322 9 332 165 2 0 2.3 1.8 11/29/2005 12:40:00 17.8 1.8 21.8 13.7 17.7 1.7 21.8 13.3 17.3 1.9 22.6 13 323 10 309 165 2.1 0 2.3 1.8 11/29/2005 12:50:00 17.8 1.7 22.1 13.3 17.7 1.7 22.6 13 17.5 1.7 22.9 13.3 326 8 301 165 2.3 0 2.3 2.1 11/29/2005 13:00:00 17.7 1.9 21.8 13 17.6 1.8 21.8 12.6 17.3 2.1 22.1 11.5 323 9 322 165 2.3 0 2.3 2.1 11/29/2005 13:10:00 21.2 2.2 27.1 16.8 21 2.1 26.8 16.8 21.1 2.4 28.3 15.6 324 7 322 165 2.1 0 2.3 1.8 11/29/2005 13:20:00 21.9 2.2 26.8 12.6 21.8 2.2 26 12.2 21.6 2.3 26.3 14.5 324 6 319 165 1.9 0.1 2.3 1.6 11/29/2005 13:30:00 21.2 1.9 26.3 15.6 21.1 1.9 26.3 16.1 21.1 2.2 26.8 14.9 322 6 325 165 1.8 0 1.8 1.6 11/29/2005 13:40:00 23.1 1.8 26.8 15.3 23 1.8 26.8 15.6 22.8 2.2 27.5 16.1 320 6 302 165 1.8 0.1 1.8 1.4 11/29/2005 13:50:00 22.4 1.9 26.3 15.6 22.3 1.9 26.3 15.3 22.3 2 26.8 14.9 322 6 315 165 1.9 0 2.1 1.8 11/29/2005 14:00:00 20.4 1.5 24.4 14.9 20.3 1.5 24.4 14.9 20.4 1.7 23.7 13.7 324 6 321 165 1.8 0 1.8 1.8 11/29/2005 14:10:00 18.5 1.5 22.6 14.5 18.4 1.5 22.1 14.1 18.3 1.7 24 12.6 322 7 325 165 1.7 0 1.8 1.6 11/29/2005 14:20:00 18.9 1.5 22.6 15.3 18.8 1.5 22.9 14.5 18 1.7 22.1 13.7 316 6 309 165 1.6 0 1.6 1.6 11/29/2005 14:30:00 19.2 1.5 23.3 15.6 19.1 1.5 22.9 15.3 18.6 1.7 22.9 11.5 314 5 314 165 1.5 0 1.6 1.4 11/29/2005 14:40:00 20.2 1.5 23.3 16.4 20.1 1.5 23.7 16.1 20 1.6 23.7 15.6 315 5 318 165 1.5 0 1.6 1.4 11/29/2005 14:50:00 20.1 1.6 24.8 14.9 20 1.6 24.8 14.5 19.5 2.1 24.8 12.6 316 5 315 165 1.5 0 1.6 1.4 11/29/2005 15:00:00 20.6 1.4 24 16.1 20.5 1.4 23.7 16.4 19.9 1.7 24.4 13.7 315 5 312 165 1.6 0 1.6 1.4 11/29/2005 15:10:00 20.4 1.4 24 15.6 20.3 1.5 23.7 15.6 19.9 1.5 24 15.3 316 5 307 165 1.8 0.1 1.8 1.6 11/29/2005 15:20:00 21.2 1.5 24.4 17.2 21.1 1.5 24 16.8 20.7 1.7 24 15.6 316 5 320 165 1.9 0 2.1 1.8 11/29/2005 15:30:00 21.3 2 26.3 14.9 21.2 2 26.3 15.3 20.9 2.3 26 14.5 317 5 310 165 1.9 0 2.1 1.8 11/29/2005 15:40:00 23.1 1.6 26.8 19.1 23.1 1.6 27.1 19.5 22.9 1.6 27.1 18.3 316 5 316 165 1.9 0 2.1 1.8 11/29/2005 15:50:00 23.2 1.8 26.8 18.7 23.2 1.9 26.8 18.3 22.8 1.9 26.8 17.2 314 5 313 165 1.8 0 1.8 1.6 11/29/2005 16:00:00 24.7 1.3 27.1 20.6 24.7 1.3 27.5 20.6 24.1 1.5 27.1 19.9 312 4 306 165 1.6 0 1.8 1.6 11/29/2005 16:10:00 25.8 1.6 29.8 19.1 25.8 1.6 29.4 18.7 24.9 1.8 27.9 17.6 311 5 305 165 1.7 0 1.8 1.6 11/29/2005 16:20:00 24.3 1.9 29.8 17.2 24.3 1.9 30.2 17.6 24 2.1 29.1 18.3 318 7 315 165 1.5 0.1 1.8 1.4 11/29/2005 16:30:00 25.5 1.9 30.9 20.2 25.4 1.9 30.6 20.6 25.4 2.2 31.8 19.1 323 6 324 165 1.4 0 1.6 1.1 11/29/2005 16:40:00 24 1.7 27.9 18.7 24 1.7 27.9 18.7 24 1.8 28.3 19.5 323 6 322 165 1.4 0 1.6 1.4 11/29/2005 16:50:00 22.6 1.5 26.8 17.6 22.4 1.6 26.3 17.2 22.5 1.8 26.3 17.2 323 4 328 165 1.2 0 1.6 1.1 11/29/2005 17:00:00 20 1.4 22.6 16.1 19.9 1.4 22.9 16.1 19.7 1.4 22.9 16.1 321 8 306 165 1 0 1.1 0.9 11/29/2005 17:10:00 20.3 2.2 25.2 14.9 20.2 2.2 25.2 14.5 19.8 2.1 24 13.3 317 7 307 165 1.2 0.2 1.6 0.9 11/29/2005 17:20:00 20.7 1.4 24.4 17.6 20.7 1.4 24.4 17.6 19.9 1.6 24 15.6 313 5 314 165 1.4 0.1 1.6 1.4 11/29/2005 17:30:00 21.4 1.5 25.2 17.6 21.4 1.5 24.8 17.6 20.7 1.7 24.8 15.6 314 5 319 165 1.4 0 1.6 1.4 11/29/2005 17:40:00 19.3 1.6 22.9 14.9 19.2 1.6 23.3 15.3 18.7 1.5 23.3 14.1 316 6 310 165 1.2 0 1.4 1.1 11/29/2005 17:50:00 20.2 1.5 24 15.3 20.1 1.5 23.7 15.3 19.7 1.7 24.4 14.5 315 5 315 165 1.2 0 1.4 1.1 11/29/2005 18:00:00 20.3 1.8 24.8 14.5 20.2 1.8 25.2 14.5 19.6 1.8 24.8 14.5 317 7 313 165 1 0 1.4 0.9 11/29/2005 18:10:00 20.2 1.5 24 15.6 20.1 1.5 24 16.1 19.8 1.7 24 15.3 320 7 321 165 0.9 0 1.1 0.9 11/29/2005 18:20:00 19.3 1.7 23.7 14.9 19.2 1.7 22.9 14.9 19 1.7 24.4 14.9 322 8 343 165 0.9 0 1.1 0.9 11/29/2005 18:30:00 21.4 2.3 27.1 15.6 21.3 2.3 27.1 15.3 21.2 2.6 27.9 14.5 322 8 320 165 0.9 0 1.1 0.9 11/29/2005 18:40:00 22.4 2.4 27.5 16.8 22.3 2.4 27.9 16.1 21.7 2.5 26.8 15.6 317 7 315 165 0.9 0 1.1 0.9 11/29/2005 18:50:00 22.1 2.2 28.7 16.8 22 2.2 28.3 17.2 21.4 2.4 29.1 14.5 318 8 329 165 0.9 0 1.1 0.9 11/29/2005 19:00:00 23.7 2.1 29.1 18.3 23.6 2.1 28.7 17.6 23.5 2.3 28.7 17.9 320 6 318 165 1.1 0 1.4 0.9 11/29/2005 19:10:00 23.5 2.5 29.1 17.6 23.4 2.6 29.1 17.6 23.2 2.7 30.2 17.2 318 7 319 165 1.2 0 1.4 0.9 11/29/2005 19:20:00 21.7 2 26.3 15.6 21.6 2 26 14.9 21.1 2.4 26.8 14.5 320 8 328 165 1 0 1.4 0.9 11/29/2005 19:30:00 22.2 2.1 28.7 14.5 22.1 2.1 28.7 14.5 21.9 2.3 27.5 15.3 321 7 310 165 1 0 1.1 0.9 11/29/2005 19:40:00 22.2 1.9 27.5 16.4 22.1 2 27.1 16.8 21.5 2.2 28.3 15.3 319 7 307 165 0.9 0 1.1 0.9 11/29/2005 19:50:00 22.5 1.9 27.5 16.8 22.4 1.9 27.5 17.2 22.4 1.8 26.8 16.8 320 6 312 165 0.8 0 1.1 0.9 11/29/2005 20:00:00 21.2 2.1 26.8 15.6 21 2.1 26.8 15.3 20.7 2.3 27.9 13.7 320 7 322 165 0.8 0 0.9 0.7 11/29/2005 20:10:00 20.7 1.8 26 16.1 20.5 1.8 26 15.6 20.2 2 24.8 14.5 321 6 309 165 0.7 0 0.9 0.7 11/29/2005 20:20:00 21.3 2.1 27.5 14.5 21.2 2.1 27.5 14.1 20.9 2.2 26.3 14.9 322 8 307 165 0.8 0 0.9 0.7 11/29/2005 20:30:00 19.7 2.5 27.9 14.1 19.6 2.5 27.1 13.7 19.2 2.5 26 13.3 324 10 318 165 0.8 0 0.9 0.7 11/29/2005 20:40:00 20.9 2.3 29.1 15.6 20.9 2.3 28.7 15.6 20.1 2.4 26.8 12.2 318 8 306 165 0.8 0 0.9 0.7 11/29/2005 20:50:00 20.2 2.1 26 12.6 20.1 2.1 26 12.6 19.7 2.4 26.3 12.2 320 7 310 165 0.8 0 0.9 0.9 11/29/2005 21:00:00 23.5 2.4 31.3 17.2 23.4 2.4 31.8 17.6 22.9 2.5 30.2 15.3 318 6 310 165 0.9 0 1.1 0.9 11/29/2005 21:10:00 23.7 1.8 29.4 18.7 23.6 1.8 29.1 17.9 23.2 1.9 29.4 18.3 318 6 321 165 0.9 0 1.1 0.9 11/29/2005 21:20:00 22.6 2.3 29.1 16.4 22.4 2.3 28.7 16.1 21.8 2.8 28.7 13.7 320 8 316 165 0.8 0 0.9 0.7 11/29/2005 21:30:00 22.1 2.4 26.8 14.9 22 2.3 26.3 15.3 21.6 2.7 29.1 14.1 322 8 321 165 0.7 0 0.9 0.7 11/29/2005 21:40:00 22.1 1.8 27.5 16.8 21.9 1.8 27.1 16.1 21.9 2 27.1 16.1 322 8 315 165 0.7 0 0.9 0.7 11/29/2005 21:50:00 21.1 2.3 26.3 15.3 21 2.2 26.3 15.6 20.5 2.5 29.1 13.3 319 8 327 165 0.6 0 0.9 0.4 11/29/2005 22:00:00 21.5 1.9 26 15.3 21.3 1.9 26 15.3 21.1 2.2 27.1 15.3 322 8 322 165 0.7 0 0.9 0.7 11/29/2005 22:10:00 21.9 2 27.5 16.1 21.7 2 26.8 16.4 21.4 2.2 27.1 16.1 322 8 324 165 0.5 0 0.7 0.4 11/29/2005 22:20:00 23.2 2.1 28.3 17.9 23 2.2 28.3 17.6 22.7 2.3 27.9 16.1 322 6 320 165 0.7 0.1 0.9 0.7 11/29/2005 22:30:00 24.8 2.5 29.8 18.7 24.6 2.5 30.2 17.9 24.5 2.7 30.9 17.9 324 8 314 165 0.8 0 0.9 0.7 11/29/2005 22:40:00 26.3 2.9 33.2 16.8 26.2 2.9 33.6 16.8 25.9 3.1 31.8 15.6 321 6 312 165 0.8 0 0.9 0.7 11/29/2005 22:50:00 26.6 2.5 33.6 19.1 26.5 2.6 33.6 19.1 26.2 2.7 32.9 16.8 321 7 318 165 0.7 0 0.9 0.7 11/29/2005 23:00:00 28.1 2.4 32.9 20.2 28 2.4 32.9 20.6 27.9 2.6 33.2 19.5 320 6 314 165 0.7 0 0.9 0.7 11/29/2005 23:10:00 29.5 2.1 34.4 24 29.4 2.1 34.4 24 29.2 2.4 34.4 22.6 319 5 322 165 0.5 0 0.7 0.4 11/29/2005 23:20:00 28.2 1.7 33.2 23.3 28 1.7 33.2 23.7 28 1.9 33.2 20.6 321 6 321 165 0.5 0 0.7 0.2 11/29/2005 23:30:00 28.9 2 33.6 21 28.8 2 34 21 28.5 2.3 33.6 20.6 318 4 321 165 0.4 0 0.7 0.2 11/29/2005 23:40:00 28.4 1.9 33.6 22.1 28.3 1.9 33.6 22.1 28.1 2.1 33.2 21.4 319 6 313 165 0.5 0 0.7 0.2 11/29/2005 23:50:00 27.7 2.2 33.2 21.4 27.6 2.2 32.9 21.4 27.4 2.4 32.4 20.6 319 5 307 165 0.5 0 0.7 0.2 11/30/2005 00:00:00 26.4 2.6 34.4 19.5 26.3 2.6 34.4 18.3 25.9 2.6 31.3 18.3 320 8 307 165 0.4 0 0.7 0.2 11/30/2005 00:10:00 28.1 2 33.2 23.3 28 2 32.9 22.9 27.9 2.2 33.2 21.8 319 6 317 165 0.2 0 0.4 0.2 11/30/2005 00:20:00 26.2 1.9 30.9 20.6 26.1 1.9 30.6 21 25.8 2.1 31.8 20.2 320 6 318 165 0.2 0 0.2 0.2 11/30/2005 00:30:00 25 1.8 30.6 19.9 24.9 1.8 29.8 20.2 24.7 2.5 29.8 16.4 320 7 322 165 0.1 0 0.2 0.2 11/30/2005 00:40:00 23.5 2.2 28.3 14.9 23.4 2.2 27.9 14.9 23.2 2.4 29.4 14.1 321 7 313 165 0.1 0 0.2 -0.1 11/30/2005 00:50:00 22.2 2.3 27.1 16.4 22.1 2.3 27.1 15.6 22 2.3 29.1 16.4 322 7 316 165 0.1 0 0.2 -0.1 11/30/2005 01:00:00 21.4 2.1 27.1 15.3 21.3 2.1 27.1 14.9 21.2 2.2 28.3 15.3 322 8 307 165 0.1 0 0.2 -0.1 11/30/2005 01:10:00 19.9 2.5 26.8 13.7 19.8 2.4 26 13.7 19.5 2.6 26.3 13.7 322 8 325 165 0.1 0 0.2 -0.1 11/30/2005 01:20:00 21.1 1.9 26.3 16.1 20.9 1.9 26 16.1 20.4 2.1 24.8 14.9 317 8 307 165 0.1 0 0.2 -0.1 11/30/2005 01:30:00 21.4 1.5 24.4 16.1 21.3 1.5 24.4 16.1 19.9 1.5 23.3 14.9 312 6 312 165 0.1 0 0.2 -0.1 11/30/2005 01:40:00 21.5 1.8 25.6 16.1 21.3 1.8 25.6 15.6 20.6 2 26 14.1 314 6 310 165 0.1 0 0.2 -0.1 11/30/2005 01:50:00 22.3 1.8 26.8 17.2 22.2 1.8 26.8 17.2 21.8 2.2 27.1 15.6 317 7 309 165 0 0 0.2 -0.1 11/30/2005 02:00:00 23.5 1.9 27.9 17.9 23.4 2 27.9 17.9 23.2 2.3 28.7 16.1 318 6 323 165 0 0 0.2 -0.1 11/30/2005 02:10:00 23 2.1 28.3 16.1 22.9 2.1 28.3 16.1 22.5 2.1 29.1 16.1 317 7 314 165 0.1 0 0.2 -0.1 11/30/2005 02:20:00 20.7 2 26 15.3 20.6 2 26 15.6 20.2 2.2 26 15.6 317 7 327 165 0.1 0 0.2 -0.1 11/30/2005 02:30:00 20.8 1.9 25.6 15.6 20.7 1.9 25.2 15.3 19.8 2.1 25.6 12.6 317 8 318 165 0.1 0 0.2 -0.1 11/30/2005 02:40:00 22.3 2.3 27.5 16.8 22.2 2.4 27.5 16.8 21.9 2.5 27.5 16.1 319 7 316 165 0.2 0 0.4 -0.1 11/30/2005 02:50:00 22.9 1.7 26.8 17.2 22.8 1.7 26.3 17.9 22.6 1.8 27.1 17.9 321 8 317 165 0.3 0 0.7 0.2 11/30/2005 03:00:00 23.3 2.1 28.7 16.4 23.2 2.1 28.7 16.8 23 2.1 27.1 16.1 321 8 324 165 0.4 0 0.7 0.2 11/30/2005 03:10:00 23.2 1.9 29.1 18.7 23.1 2 29.1 18.3 22.7 2.2 28.7 17.9 322 9 312 165 0.4 0 0.7 0.2 11/30/2005 03:20:00 20.7 2.1 26.8 15.6 20.6 2.1 27.1 15.6 20.2 2.3 25.6 14.1 324 9 341 165 0.5 0 0.7 0.2 11/30/2005 03:30:00 19.7 2.3 25.2 13 19.7 2.3 25.2 11.5 19.5 2.3 24.8 14.1 327 11 325 165 0.5 0 0.7 0.2 11/30/2005 03:40:00 21.4 2.5 27.1 14.9 21.2 2.5 27.1 14.9 20.5 2.6 26.3 12.2 320 8 323 165 0.3 0 0.7 0.2 11/30/2005 03:50:00 22.6 2.1 27.5 17.6 22.5 2.1 27.5 17.6 21.9 2.4 28.7 15.6 320 8 321 165 0.4 0 0.7 0.2 11/30/2005 04:00:00 23.8 2.3 31.3 17.9 23.6 2.3 30.9 17.2 23.5 2.5 30.6 17.2 325 8 315 165 0.5 0 0.7 0.2 11/30/2005 04:10:00 24.7 2.6 31.3 18.3 24.5 2.6 30.9 17.9 24.4 2.8 31.8 16.8 325 9 332 165 0.6 0 0.7 0.4 11/30/2005 04:20:00 24.5 2.3 30.9 16.8 24.3 2.4 30.9 16.1 24 2.4 32.1 17.9 322 7 322 165 0.4 0 0.7 0.2 11/30/2005 04:30:00 24.2 2.7 32.1 15.3 24.1 2.8 32.4 15.3 23.8 3.1 32.9 14.9 321 9 323 165 0.4 0.1 0.7 0.2 11/30/2005 04:40:00 24.5 1.9 29.4 19.5 24.4 2 29.4 18.7 24 2.1 30.2 17.2 318 8 319 165 0.5 0 0.7 0.2 11/30/2005 04:50:00 22.1 2.4 27.9 14.9 22 2.4 26.8 14.9 21.7 2.4 28.3 14.5 322 10 319 165 0.4 0 0.7 0.2 11/30/2005 05:00:00 21.1 1.7 25.6 15.6 21 1.7 25.6 16.1 20.7 1.9 26 15.6 323 9 312 165 0.3 0 0.7 0.2 11/30/2005 05:10:00 22.5 1.9 27.1 15.6 22.4 1.9 27.1 16.1 22.1 2 26.8 15.6 319 7 310 165 0.4 0 0.7 0.2 11/30/2005 05:20:00 22.8 1.7 27.1 17.6 22.7 1.7 27.1 16.8 22.4 1.8 26.3 16.8 320 8 306 165 0.3 0 0.7 0.2 11/30/2005 05:30:00 23.6 1.9 30.2 17.2 23.4 1.9 30.2 17.2 23.2 2.2 27.9 17.9 320 7 307 165 0.2 0 0.4 -0.1 11/30/2005 05:40:00 22.5 1.8 28.7 16.4 22.4 1.8 28.3 16.4 22.1 2 28.7 16.1 319 6 326 165 0.1 0 0.2 -0.1 11/30/2005 05:50:00 24.3 1.5 28.7 19.5 24.2 1.5 28.7 19.9 23.8 1.7 27.5 18.3 318 5 316 165 0.2 0 0.2 0.2 11/30/2005 06:00:00 24.5 1.7 28.7 18.7 24.4 1.8 28.7 18.7 24.2 1.8 28.7 19.1 319 7 310 165 0.2 0 0.2 0.2 11/30/2005 06:10:00 23 1.6 29.1 19.9 22.9 1.6 29.1 19.5 22.8 1.8 28.7 16.4 322 7 321 165 0.2 0 0.4 -0.1 11/30/2005 06:20:00 24.2 1.9 28.7 18.3 24 1.9 28.7 18.3 23.7 2.3 29.1 16.8 320 7 318 165 0.3 0 0.7 0.2 11/30/2005 06:30:00 24.4 1.9 30.2 17.6 24.3 1.9 30.2 17.9 23.9 2 29.1 17.6 318 7 313 165 0.4 0 0.7 0.2 11/30/2005 06:40:00 23.4 2.3 31.3 16.8 23.3 2.3 30.6 16.8 22.8 2.5 30.6 16.8 319 8 306 165 0.4 0 0.7 0.2 11/30/2005 06:50:00 23 2.5 29.1 16.4 22.8 2.5 29.1 16.8 22.4 2.8 30.6 14.9 324 8 311 165 0.5 0 0.7 0.2 11/30/2005 07:00:00 22.2 2.4 28.3 14.9 22.1 2.4 27.9 14.5 21.7 2.4 27.1 14.5 325 11 328 165 0.4 0.1 0.7 0.2 11/30/2005 07:10:00 20.5 2.1 25.2 13.7 20.3 2.1 24.8 13.7 19.8 2.2 24.4 14.1 329 10 327 165 0.3 0 0.4 0.2 11/30/2005 07:20:00 21.5 2.5 28.3 14.1 21.4 2.5 28.3 14.1 21 2.7 28.7 14.1 322 8 316 165 0.4 0 0.7 0.2 11/30/2005 07:30:00 19.1 2.2 24.8 12.6 19.1 2.1 24.8 13.7 18.4 2.3 23.7 11.1 322 10 315 165 0.3 0 0.7 0.2 11/30/2005 07:40:00 19.4 2.4 26.8 13.7 19.4 2.4 27.1 13.7 18.9 2.6 28.3 11.8 323 11 312 165 0.4 0 0.7 0.2 11/30/2005 07:50:00 19.1 2.2 24.8 13 19 2.2 24.8 12.6 18.7 2.6 25.2 11.5 320 9 319 165 0.4 0 0.7 0.2 11/30/2005 08:00:00 17.8 2.2 23.7 12.6 17.7 2.2 23.7 12.2 17.1 2.3 23.3 11.5 324 11 319 165 0.4 0 0.7 0.2 11/30/2005 08:10:00 18.4 2.4 25.6 12.2 18.4 2.4 25.6 12.2 18.1 2.5 24.4 11.5 325 11 307 165 0.4 0 0.7 0.2 11/30/2005 08:20:00 19.1 2.4 24.8 13.3 19 2.4 25.2 13.3 18.4 2.3 26 12.6 322 11 312 165 0.4 0 0.7 0.2 11/30/2005 08:30:00 18.1 2.2 22.9 12.2 18 2.2 23.7 12.2 17.4 2.3 23.7 11.1 323 9 315 165 0.2 0 0.7 -0.1 11/30/2005 08:40:00 17.9 2.3 23.7 12.2 17.8 2.3 24 11.5 16.8 2.7 24 11.1 321 10 311 165 0.1 0 0.2 -0.1 11/30/2005 08:50:00 17.2 1.8 22.9 11.8 17.2 1.8 22.6 11.1 16.4 2 22.1 10.7 320 10 330 165 0.1 0 0.2 -0.1 11/30/2005 09:00:00 16.6 1.9 21 12.2 16.5 1.9 21.8 11.5 15.8 2 21.8 11.5 323 10 349 165 0 0 0.2 -0.1 11/30/2005 09:10:00 18.5 2.4 25.6 12.2 18.5 2.4 25.6 12.2 18.4 2.6 24.4 10.3 329 12 318 165 0.1 0 0.2 -0.1 11/30/2005 09:20:00 14.7 2.2 21 9.1 14.6 2.2 22.1 9.5 13.9 2.2 20.6 8.8 324 12 302 165 0.1 0 0.2 -0.1 11/30/2005 09:30:00 12.5 2.3 18.7 6.8 12.4 2.2 18.3 5.7 11.4 2.2 17.6 3.8 322 17 305 165 0.1 0 0.4 -0.1 11/30/2005 09:40:00 16.6 2.2 22.6 11.8 16.5 2.2 22.1 11.8 16 2.4 22.6 9.9 320 12 311 165 0.7 0 0.9 0.2 11/30/2005 09:50:00 18.8 2.8 27.5 11.8 18.7 2.8 27.9 11.5 18.3 2.7 25.6 11.5 327 11 317 165 0.8 0 0.9 0.7 11/30/2005 10:00:00 20.6 2.8 27.5 14.1 20.6 2.8 27.5 14.5 19.8 3.1 26.3 11.5 322 12 297 165 0.9 0 1.1 0.9 11/30/2005 10:10:00 20.3 2.7 27.9 13 20.2 2.7 27.5 11.1 19.4 2.7 26.8 13.3 321 12 307 165 0.9 0 1.1 0.9 11/30/2005 10:20:00 18.6 2.5 26.8 13 18.4 2.5 26.3 13 17.2 2.5 25.2 11.5 319 13 309 165 0.8 0 1.1 0.9 11/30/2005 10:30:00 18.9 2.7 27.9 11.5 18.8 2.8 27.9 11.5 17.9 2.4 26 11.8 323 15 302 165 0.8 0 0.9 0.9 11/30/2005 10:40:00 18.9 2.3 27.5 12.6 18.9 2.3 26.8 12.6 18.4 2.6 26.8 12.6 323 11 322 165 0.8 0 0.9 0.7 11/30/2005 10:50:00 19.7 2.8 27.1 11.8 19.6 2.8 26.8 12.2 19.2 2.9 27.1 11.8 321 9 314 165 0.8 0 0.9 0.7 11/30/2005 11:00:00 20.2 2.3 26 14.9 20.1 2.3 26 14.9 19.8 2.6 26 13.3 323 12 338 165 0.7 0 0.9 0.4 11/30/2005 11:10:00 18.5 2.1 24 11.8 18.4 2.2 24 11.8 18.1 2.2 23.3 11.5 324 10 301 165 0.5 0 0.9 0.2 11/30/2005 11:20:00 17.3 1.7 23.7 12.6 17.2 1.7 23.3 12.2 17 1.9 22.6 12.2 322 9 329 165 0.3 0 0.4 0.2 11/30/2005 11:30:00 16.1 2.3 22.9 10.7 16.1 2.2 22.6 11.5 15 2 19.9 8 318 11 305 165 0.7 0.2 0.9 0.2 11/30/2005 11:40:00 16.1 2 22.1 10.7 16 2 22.1 10.7 15.1 2.1 20.6 9.9 317 9 292 165 0.8 0 1.1 0.7 11/30/2005 11:50:00 14.6 2.1 23.3 9.9 14.3 2.2 21 7.6 14.1 2.2 23.7 9.5 325 17 349 165 0.9 0 1.1 0.7 11/30/2005 12:00:00 12.9 1.7 17.2 8.4 12.4 2.1 17.2 7.2 12.2 2.3 20.2 6.1 332 18 351 165 1 0 1.4 0.9 11/30/2005 12:10:00 12.7 2.3 21 8.8 12.6 2.3 21.4 8.4 11.5 2.3 19.5 6.8 318 13 304 165 0.6 0 1.1 0.4 11/30/2005 12:20:00 15.1 2.4 21.4 10.3 15.1 2.4 21.8 9.9 13.8 2.2 21.4 9.1 315 12 312 165 0.5 0 0.7 0.2 11/30/2005 12:30:00 13.3 1.6 17.9 9.9 13.3 1.7 17.9 9.5 12.6 1.9 18.3 8.4 319 12 327 165 0.6 0 0.7 0.4 11/30/2005 12:40:00 10.4 1.1 13.7 7.2 10.4 1.1 13.3 7.2 9.9 1.3 14.1 6.5 319 13 333 165 0.6 0 0.7 0.7 11/30/2005 12:50:00 9.4 1.2 12.6 5.3 9.3 1.2 12.6 5.7 8.9 1.2 12.2 5.7 317 9 309 165 0.4 0 0.7 0.2 11/30/2005 13:00:00 10.6 2.2 17.9 6.5 10.4 2.3 17.9 6.5 9.6 2.1 16.4 4.9 315 10 298 165 0.5 0 0.7 0.2 11/30/2005 13:10:00 14.9 1.9 21 10.3 14.9 1.9 21 10.3 14.1 2 19.5 8.8 322 11 310 165 0.2 0 0.7 -0.1 11/30/2005 13:20:00 14.6 2.2 21.8 10.3 14.6 2.2 21.8 9.9 14.3 2.3 20.6 9.5 323 10 310 165 0.3 0 0.7 0.2 11/30/2005 13:30:00 11.7 1.5 14.5 7.2 11.7 1.5 15.3 7.6 11.4 1.6 15.3 7.2 326 10 342 165 0.3 0 0.7 0.2 11/30/2005 13:40:00 11.3 1.1 14.9 8 11.2 1.1 14.9 8.4 10.8 1 14.1 7.6 320 10 321 165 0.2 0 0.4 0.2 11/30/2005 13:50:00 11.2 1 14.1 7.6 11.1 1 14.1 8 10.6 1.2 13.7 6.8 316 8 318 165 0.2 0 0.2 0.2 11/30/2005 14:00:00 11 1.1 13.7 8 10.9 1.1 13.3 8 10.1 1.2 13.7 6.5 313 7 309 165 0.2 0 0.2 -0.1 11/30/2005 14:10:00 10.6 1 13.7 8 10.5 1 13.7 7.6 10.2 1 12.6 7.2 319 8 305 165 0.2 0 0.4 0.2 11/30/2005 14:20:00 10.5 1 13.3 7.2 10.4 1 13 7.6 9.8 1.1 13 6.8 315 8 304 165 0.2 0 0.4 0.2 11/30/2005 14:30:00 10.2 1 13.7 7.6 10.1 1 13.7 7.6 9.3 1.1 13.3 6.1 315 8 325 165 0.1 0 0.2 -0.1 11/30/2005 14:40:00 10 1.2 14.1 6.8 9.9 1.3 14.1 6.8 9.3 1.2 14.9 6.1 316 9 307 165 0.1 0 0.2 -0.1 11/30/2005 14:50:00 11.3 1.3 14.1 8 11.2 1.3 13.7 8 9.5 1.3 13 5.7 309 7 307 165 0.2 0 0.2 0.2 11/30/2005 15:00:00 10.9 0.8 13 8.8 10.8 0.8 13 8.4 9.8 1.1 12.6 7.2 312 5 308 165 0.1 0 0.2 -0.1 11/30/2005 15:10:00 10.5 1.1 13.7 8.4 10.3 1.1 13.3 7.6 9.3 1.3 12.2 6.1 313 9 300 165 -0.1 0 0.2 -0.1 11/30/2005 15:20:00 11.9 1.7 16.1 8 11.8 1.7 16.1 7.6 11.2 1.8 16.8 7.6 318 11 328 165 0 0 0.2 -0.1 11/30/2005 15:30:00 11.5 1.6 15.6 7.6 11.5 1.6 16.1 8 10.7 1.6 15.6 7.6 318 10 338 165 0.1 0 0.2 -0.1 11/30/2005 15:40:00 10.2 1.5 15.3 6.5 10.1 1.6 15.3 4.9 9.6 1.4 16.1 6.1 324 15 325 165 -0.1 0 0.2 -0.1 11/30/2005 15:50:00 10.1 2 15.6 6.5 10.1 2 15.3 6.1 9.6 2.2 15.3 4.9 318 11 326 165 0 0 0.2 -0.3 11/30/2005 16:00:00 10.7 1.7 19.5 7.2 10.6 1.7 18.7 7.2 10 2 18.7 6.1 318 14 323 165 -0.2 0 -0.1 -0.3 11/30/2005 16:10:00 11 1.8 15.6 5.7 11 1.8 15.3 5.7 10 1.8 14.9 5.3 313 13 307 165 -0.2 0 -0.1 -0.3 11/30/2005 16:20:00 9.9 2.5 16.4 3.8 9.9 2.5 16.8 4.2 8.9 2.1 16.1 4.9 317 17 291 165 -0.3 0 -0.1 -0.5 11/30/2005 16:30:00 9.8 2 15.3 5.7 9.7 2.1 15.6 5.7 9 1.8 14.5 5.3 320 17 316 165 -0.5 0.1 -0.3 -0.8 11/30/2005 16:40:00 8.1 1.7 12.6 4.2 7.9 1.9 12.6 3.4 7.8 1.5 11.5 4.2 330 16 303 165 -0.6 0 -0.3 -0.8 11/30/2005 16:50:00 6.1 1.1 8.8 3.4 5.7 1.2 8.8 3 5.7 1.2 8.4 2.6 338 21 350 165 -0.9 0.1 -0.5 -1.2 11/30/2005 17:00:00 6.5 1.2 10.7 4.2 6.4 1.3 10.7 3.8 5.9 1.2 9.5 3 319 17 319 165 -0.6 0.1 -0.3 -0.8 11/30/2005 17:10:00 8.2 1.7 13 4.2 8 1.7 13.3 4.2 7.8 1.8 12.6 3.8 322 13 311 165 -0.4 0 -0.3 -0.5 11/30/2005 17:20:00 9.9 1.2 13 6.8 9.8 1.2 13 6.8 8.7 1.2 13.3 5.3 310 8 306 165 -0.6 0.1 -0.3 -0.8 11/30/2005 17:30:00 9.3 0.9 12.2 5.7 9.2 0.8 11.5 6.1 8.2 1 11.5 5.7 311 7 304 165 -1 0 -0.8 -1.2 11/30/2005 17:40:00 7.9 1.5 13 4.9 7.8 1.5 12.6 4.9 6.9 1.4 11.5 3.4 309 9 307 165 -1 0 -0.8 -1.2 11/30/2005 17:50:00 7.3 1 11.1 4.9 7.3 1 11.1 4.6 6.3 0.9 9.5 4.2 308 8 292 165 -1.2 0 -1 -1.4 11/30/2005 18:00:00 7.5 1.1 10.3 4.6 7.4 1.1 9.9 4.6 6.6 1.2 9.5 3.4 311 8 304 165 -1.4 0.1 -1.2 -1.7 11/30/2005 18:10:00 7.1 0.9 9.5 4.9 7.1 1 9.9 4.9 6.3 0.9 9.1 4.2 314 8 317 165 -1.5 0 -1.4 -1.7 11/30/2005 18:20:00 7.2 1 9.9 4.9 7.2 1 9.9 4.9 6.3 1.2 10.7 3.4 312 8 323 165 -1.4 0 -1.4 -1.4 11/30/2005 18:30:00 7.1 1.1 9.5 4.6 7.1 1.1 9.5 4.6 6.2 1.1 9.5 3.8 312 9 310 165 -1.3 0 -1.2 -1.7 11/30/2005 18:40:00 8.4 1 11.5 6.1 8.3 1 11.1 5.7 7.9 1.1 11.1 4.9 320 8 317 165 -1 0 -0.8 -1.4 11/30/2005 18:50:00 9.2 1.5 12.6 4.6 9.1 1.6 12.6 4.9 8.9 1.6 12.2 4.6 319 7 326 165 -1 0.1 -0.8 -1.2 11/30/2005 19:00:00 8.4 0.9 11.8 6.5 8.4 0.9 11.8 6.5 7.9 1 11.5 4.9 316 7 309 165 -1.2 0.1 -0.8 -1.4 11/30/2005 19:10:00 8.3 1.1 11.8 5.3 8.2 1.1 11.5 5.7 7.9 1.2 11.5 5.3 319 7 318 165 -1.3 0.1 -1.2 -1.4 11/30/2005 19:20:00 6.3 1 8.8 3.8 6.1 1 8.8 3.4 5.7 1 9.1 2.6 323 14 317 165 -1.7 0.1 -1.4 -1.9 11/30/2005 19:30:00 6.2 1 8.8 3.8 6.1 1 8.8 3.4 5.8 1.1 9.5 3.4 326 9 321 165 -1.7 0.1 -1.4 -1.9 11/30/2005 19:40:00 7.3 1.3 10.7 4.6 7.2 1.3 10.7 4.6 6.5 1.2 9.9 4.6 318 11 301 165 -1.9 0.2 -1.4 -2.1 11/30/2005 19:50:00 8 1.4 11.5 4.2 7.4 1.5 12.2 4.2 7.3 1.3 11.1 3.8 345 9 344 165 -1.7 0 -1.4 -1.9 11/30/2005 20:00:00 7.7 0.9 11.5 5.3 7.6 0.9 12.2 4.9 7.3 0.8 11.8 5.3 328 11 345 165 -1.7 0 -1.4 -1.9 11/30/2005 20:10:00 8.7 1.3 12.6 5.7 8.3 1.4 12.6 5.3 8.2 1.3 12.2 4.6 334 16 338 165 -1.6 0 -1.4 -1.9 11/30/2005 20:20:00 9.9 1.5 13.3 6.1 9.8 1.7 14.1 4.6 9.4 1.5 13 6.1 329 16 347 165 -1.7 0 -1.4 -1.7 11/30/2005 20:30:00 9.3 1.5 13.3 5.7 9.1 1.5 13.3 5.3 8.7 1.4 12.2 5.7 323 17 314 165 -1.8 0 -1.4 -1.9 11/30/2005 20:40:00 9 1.6 13.7 4.9 9 1.5 13.7 5.3 7.9 1.7 12.6 3.4 314 12 306 165 -1.7 0 -1.4 -2.1 11/30/2005 20:50:00 8.4 1 11.8 5.3 8.4 1 11.5 5.7 7.3 1.5 12.2 3 316 13 322 165 -1.8 0 -1.4 -1.9 11/30/2005 21:00:00 9 1.2 13 6.1 9 1.3 13 6.1 8.5 1.1 12.6 5.3 318 8 322 165 -1.6 0 -1.4 -1.7 11/30/2005 21:10:00 7.3 1 10.7 5.3 7.3 1 10.3 4.9 6.9 0.8 9.1 4.9 325 13 313 165 -1.8 0.1 -1.4 -1.9 11/30/2005 21:20:00 7.7 1.3 10.7 4.6 7.6 1.4 10.7 4.2 7.4 1.4 10.7 3.8 335 11 355 165 -1.8 0 -1.7 -2.1 11/30/2005 21:30:00 7.3 1.1 9.9 4.9 7.2 1.2 10.3 4.2 7 1.1 10.3 4.6 328 15 319 165 -1.6 0 -1.4 -1.9 11/30/2005 21:40:00 6.5 1.1 9.1 4.2 6.4 1.1 8.8 3.4 5.8 1 8.8 3.4 318 11 305 165 -1.6 0 -1.4 -1.7 11/30/2005 21:50:00 7.6 1.2 10.3 4.6 7.5 1.2 10.7 4.2 7.4 1.2 9.9 4.2 332 10 344 165 -1.6 0 -1.4 -1.7 11/30/2005 22:00:00 6.9 1 9.9 4.2 6.5 1.5 9.9 3 6.8 1.1 9.9 3.8 341 11 326 165 -1.6 0 -1.4 -1.7 11/30/2005 22:10:00 6.6 1.1 9.9 4.2 6.4 1.1 9.9 3.8 6.3 1.1 9.1 3.4 323 13 312 165 -1.6 0 -1.4 -1.7 11/30/2005 22:20:00 8.3 0.7 10.3 6.8 8.2 0.7 10.3 6.5 7.4 1 10.3 4.9 312 6 302 165 -1.6 0 -1.4 -1.7 11/30/2005 22:30:00 8.7 1 11.1 5.3 8.6 1 11.1 4.9 8.1 0.9 10.7 4.9 316 8 301 165 -1.6 0 -1.4 -1.7 11/30/2005 22:40:00 8.4 1.2 12.2 5.7 8.3 1.2 12.6 5.3 7.6 1.2 13 5.3 317 11 319 165 -1.7 0 -1.4 -1.9 11/30/2005 22:50:00 7.9 0.8 10.3 5.7 7.9 0.8 9.9 5.3 7.1 0.8 9.1 4.6 311 5 305 165 -1.7 0 -1.4 -1.9 11/30/2005 23:00:00 8 0.7 10.3 6.5 7.9 0.7 10.3 6.1 7.3 0.8 9.5 4.9 313 7 311 165 -1.7 0 -1.4 -1.9 11/30/2005 23:10:00 8.5 0.9 11.1 6.5 8.3 0.9 10.7 6.5 7.7 0.8 10.3 5.3 314 6 303 165 -1.9 0 -1.7 -2.1 11/30/2005 23:20:00 9.2 0.9 11.5 6.8 9.1 0.9 11.5 6.8 8.6 0.9 10.7 6.5 315 6 313 165 -1.9 0 -1.7 -1.9 11/30/2005 23:30:00 9.7 0.8 12.6 7.6 9.6 0.8 12.2 7.6 9.3 0.9 11.5 6.5 318 6 306 165 -1.8 0 -1.7 -1.9 11/30/2005 23:40:00 10.3 0.8 12.2 8.4 10.2 0.8 12.2 8.4 9.8 0.8 11.8 6.8 317 5 314 165 -2 0 -1.9 -2.1 11/30/2005 23:50:00 10.9 0.7 13.3 9.5 10.8 0.7 13.3 9.1 10.5 0.8 13 8.4 318 5 320 165 -2 0 -1.9 -2.1 12/01/2005 00:00:00 10.7 1.1 13.3 8.4 10.6 1.1 13.3 8 10.1 1.1 13 7.2 316 6 317 165 -2 0 -1.9 -2.1 12/01/2005 00:10:00 10 0.8 12.2 8 9.9 0.8 12.2 8 9.4 0.8 11.8 7.2 316 6 309 165 -2.1 0 -1.9 -2.1 12/01/2005 00:20:00 8.9 0.8 11.1 6.8 8.8 0.8 10.7 6.5 8.4 0.8 11.1 6.1 318 6 328 165 -2 0 -1.9 -2.1 12/01/2005 00:30:00 9 0.9 12.2 6.5 8.9 0.9 12.2 6.8 8 0.9 11.5 5.7 312 6 313 165 -2 0 -1.9 -2.1 12/01/2005 00:40:00 8.9 0.9 11.1 6.5 8.8 0.9 11.5 6.1 7.9 1 11.8 5.7 312 8 312 165 -2.1 0 -1.9 -2.1 12/01/2005 00:50:00 9.1 0.8 11.8 6.8 9 0.8 11.8 6.5 8.1 0.9 11.8 6.1 312 6 309 165 -2 0 -1.9 -2.1 12/01/2005 01:00:00 9.9 1 12.6 6.8 9.8 1 12.2 6.8 9.3 1.2 13 6.1 317 8 315 165 -1.8 0 -1.7 -1.9 12/01/2005 01:10:00 9.8 1.3 13 6.8 9.8 1.3 13 6.8 9.2 1.5 16.1 5.7 317 9 313 165 -1.7 0 -1.4 -1.9 12/01/2005 01:20:00 8.9 1 11.5 6.1 8.8 1 11.5 6.1 8.2 1 11.5 5.7 322 13 327 165 -2 0 -1.9 -2.1 12/01/2005 01:30:00 8.8 1 11.5 6.1 8.5 1.2 11.5 4.9 8.3 1.3 11.5 4.9 325 16 302 165 -1.9 0 -1.9 -2.1 12/01/2005 01:40:00 8.1 0.9 11.8 5.7 8 1 11.5 3.8 7.5 1 11.8 5.3 325 13 302 165 -2 0 -1.9 -2.1 12/01/2005 01:50:00 8 1 10.7 5.3 8 1 11.1 5.3 7.5 0.9 10.3 4.9 321 12 304 165 -2 0 -1.9 -2.1 12/01/2005 02:00:00 9 1.7 14.5 4.9 8.6 1.5 13.3 4.6 8.8 1.6 14.9 4.9 336 13 358 165 -2 0 -1.9 -2.1 12/01/2005 02:10:00 10.8 1.5 15.6 6.5 10.1 1.7 14.9 6.1 10.4 1.6 15.6 7.2 337 17 352 165 -2.2 0.1 -1.9 -2.6 12/01/2005 02:20:00 9.4 1 11.8 6.1 9.3 1 11.5 6.1 9.1 1.1 11.5 5.7 324 10 317 165 -2.7 0 -2.4 -2.8 12/01/2005 02:30:00 10.7 1.2 13.7 8 10.6 1.2 13.3 8 10 1.4 12.6 6.8 316 7 318 165 -2.5 0 -2.4 -2.8 12/01/2005 02:40:00 11.5 1 14.5 9.1 11.4 1 14.1 8.8 10.9 1 13.7 8.4 318 7 310 165 -2.4 0 -2.1 -2.6 12/01/2005 02:50:00 11.3 1.1 14.1 8 11.2 1.1 13.7 8 10.5 1.2 13.3 5.7 317 9 321 165 -2.2 0 -2.1 -2.6 12/01/2005 03:00:00 10.1 1.1 13.3 6.5 10 1.1 13.3 6.5 9.6 1.2 13.3 6.1 321 11 307 165 -2.3 0.1 -2.1 -2.6 12/01/2005 03:10:00 11.3 1.3 16.1 7.6 11 1.3 14.9 7.2 10.9 1.4 15.3 7.2 331 14 343 165 -2.5 0 -2.4 -2.6 12/01/2005 03:20:00 10.5 1.3 14.9 6.1 10.4 1.3 15.3 6.5 9.6 1.3 13.3 6.5 319 15 324 165 -2.5 0 -2.4 -2.6 12/01/2005 03:30:00 9.9 1.1 13 7.2 9.8 1.1 12.6 7.2 9.5 1 12.2 7.2 331 10 350 165 -2.4 0 -2.1 -2.6 12/01/2005 03:40:00 10.3 1.5 14.5 6.5 10.2 1.5 14.1 6.1 10 1.4 14.1 6.1 335 12 352 165 -2.5 0 -2.1 -2.6 12/01/2005 03:50:00 8.8 0.9 11.5 6.1 8.7 0.9 11.5 6.1 8.4 0.9 11.1 5.3 325 11 323 165 -2.7 0 -2.6 -2.8 12/01/2005 04:00:00 10 1.5 14.1 5.7 9.9 1.5 13.7 6.1 9.3 1.7 14.1 4.9 318 8 307 165 -2.8 0 -2.6 -3 12/01/2005 04:10:00 11 1.4 15.6 8 10.9 1.5 16.1 8 10.6 1.5 15.3 7.2 321 9 316 165 -2.5 0 -2.4 -2.6 12/01/2005 04:20:00 11.7 1 14.9 9.1 11.6 1 15.3 9.1 11.3 1.1 14.5 8 318 8 321 165 -2.5 0 -2.6 -2.8 12/01/2005 04:30:00 11.9 1 14.9 9.5 11.8 1 14.9 9.5 11.2 1 14.5 8.8 316 6 309 165 -2.6 0 -2.6 -2.8 12/01/2005 04:40:00 12.2 1.3 16.1 8.4 12.1 1.3 15.6 8.4 10.9 1.3 14.1 8 313 6 306 165 -2.8 0 -2.6 -2.8 12/01/2005 04:50:00 12.7 0.9 15.6 9.9 12.6 0.9 15.3 9.9 11.9 1 14.9 8.8 315 6 324 165 -2.8 0 -2.6 -2.8 12/01/2005 05:00:00 13.2 1.3 16.8 9.9 13.1 1.3 17.2 9.5 12.5 1.5 16.8 8.8 318 7 317 165 -2.6 0 -2.6 -2.8 12/01/2005 05:10:00 11.2 1.4 15.3 7.2 11.2 1.4 16.1 7.2 10.4 1.7 15.3 6.1 318 11 312 165 -2.5 0.1 -2.4 -2.8 12/01/2005 05:20:00 11.1 1.7 17.2 6.8 11 1.7 16.8 7.6 10.4 1.6 17.6 6.5 318 10 315 165 -2.6 0.1 -2.4 -2.8 12/01/2005 05:30:00 12.4 1.3 15.6 9.1 12.3 1.2 15.3 9.5 11.5 1.2 15.3 8 314 7 304 165 -2.6 0 -2.6 -2.8 12/01/2005 05:40:00 12.2 1.2 16.4 9.1 12.1 1.2 16.1 8.8 11.1 1.2 14.1 7.2 314 8 305 165 -2.8 0 -2.6 -3 12/01/2005 05:50:00 13 1.8 17.9 8 12.9 1.7 17.9 8.4 11 1.6 15.6 6.1 309 7 295 165 -2.7 0 -2.6 -2.8 12/01/2005 06:00:00 13.4 1.3 17.6 9.9 13.3 1.2 17.2 9.9 11.7 1.6 17.9 8 312 7 316 165 -2.7 0 -2.6 -2.8 12/01/2005 06:10:00 13.6 1.5 17.2 9.5 13.5 1.5 17.2 9.5 12.6 1.4 16.8 8.8 314 6 307 165 -2.8 0 -2.6 -2.8 12/01/2005 06:20:00 14.4 1.5 17.9 10.7 14.3 1.5 17.6 10.7 13.6 1.5 17.6 9.9 315 7 301 165 -2.5 0 -2.6 -2.8 12/01/2005 06:30:00 13.4 1.3 16.4 9.1 13.2 1.3 16.1 9.1 12.3 1.5 16.4 8.8 316 6 322 165 -2.7 0 -2.4 -2.8 12/01/2005 06:40:00 13.2 1.1 16.4 10.3 13.1 1.1 16.1 9.9 12.2 1.2 14.9 8.8 314 5 314 165 -2.8 0 -2.6 -2.8 12/01/2005 06:50:00 12.6 1 15.3 9.9 12.5 1 14.5 9.5 11.5 1.2 14.9 8.4 313 7 301 165 -2.8 0 -2.6 -3 12/01/2005 07:00:00 13.7 1.4 17.6 9.1 13.6 1.4 17.2 9.1 12.6 1.5 18.3 8.8 314 7 310 165 -2.7 0 -2.6 -2.8 12/01/2005 07:10:00 13.2 1.2 16.1 10.3 13.1 1.2 16.4 10.3 12.1 1.3 16.4 9.1 314 7 314 165 -2.8 0 -2.6 -2.8 12/01/2005 07:20:00 12.6 1 15.6 9.9 12.5 1 15.6 9.9 11.6 1.1 14.5 8.8 314 7 310 165 -2.8 0 -2.8 -2.8 12/01/2005 07:30:00 11.1 1.4 14.9 8 11 1.4 15.6 7.6 10.6 1.6 14.9 6.5 324 8 339 165 -2.6 0.1 -2.6 -2.8 12/01/2005 07:40:00 10 1.6 15.3 6.1 9.9 1.5 15.3 6.5 8.8 1.8 14.5 4.6 312 13 330 165 -2.6 0.1 -2.4 -3 12/01/2005 07:50:00 8.9 1.4 12.2 5.3 8.8 1.4 11.8 5.3 7.8 1 10.7 4.9 311 10 302 165 -2.9 0 -2.8 -3 12/01/2005 08:00:00 8.3 1.9 13 4.9 8.2 1.8 12.6 4.9 7.1 1.4 11.8 4.6 312 13 296 165 -3.1 0 -2.8 -3.3 12/01/2005 08:10:00 11.7 1.4 16.8 8 11.6 1.4 16.1 7.6 10.4 1.7 14.9 5.7 312 7 301 165 -2.9 0 -2.6 -3 12/01/2005 08:20:00 10.4 1 13.7 6.8 10.3 1 13.7 6.8 9.8 1.1 13 5.7 319 9 332 165 -3 0.1 -2.8 -3 12/01/2005 08:30:00 10.5 1.2 13.7 7.2 10.4 1.2 13.3 7.2 9.6 1.4 13.3 6.5 315 7 322 165 -3 0 -2.8 -3 12/01/2005 08:40:00 11.2 1.3 16.4 8 11.1 1.3 16.4 7.6 10.1 1.3 13.7 7.2 312 8 298 165 -2.9 0 -2.8 -3 12/01/2005 08:50:00 11.2 1.2 14.9 8.4 11.1 1.2 14.9 8 10.3 1.3 14.5 6.8 315 9 321 165 -2.8 0 -2.6 -2.8 12/01/2005 09:00:00 13.4 1.6 17.2 9.1 13.2 1.6 17.2 8.8 12.4 1.5 18.3 8.8 316 8 301 165 -2.8 0 -2.6 -2.8 12/01/2005 09:10:00 13.6 1.5 16.8 9.1 13.5 1.4 16.8 9.1 12.5 1.5 16.8 8.8 315 9 305 165 -2.6 0 -2.6 -2.8 12/01/2005 09:20:00 12.3 2.1 17.6 8.8 12.3 2.1 16.8 8.4 12 2.1 17.6 6.1 325 11 313 165 -2.6 0 -2.6 -2.8 12/01/2005 09:30:00 9.7 1.5 14.5 5.3 9.6 1.7 15.3 4.6 8.9 1.7 15.3 5.3 320 16 325 165 -2.7 0 -2.6 -3 12/01/2005 09:40:00 11.5 1.7 15.6 7.6 11.3 1.7 16.4 7.2 10.8 1.5 15.6 7.2 326 16 307 165 -2.8 0.1 -2.6 -3 12/01/2005 09:50:00 14.2 2.7 21.8 6.8 13.6 2.6 21 6.5 13.4 2.7 22.1 6.5 341 13 343 165 -2.4 0 -2.1 -2.8 12/01/2005 10:00:00 15.1 2.2 22.6 9.9 15.1 2.2 22.9 8.8 14.2 2 20.6 9.9 319 11 311 165 -2.3 0 -2.1 -2.4 12/01/2005 10:10:00 19.1 2.6 25.2 12.6 19.1 2.5 25.6 13 18.2 2.7 24.8 12.2 318 15 307 165 -2.2 0 -2.1 -2.4 12/01/2005 10:20:00 19 2.1 25.6 13 19 2.1 27.1 13.3 18.3 2 24.8 12.6 321 11 301 165 -2.1 0 -1.9 -2.1 12/01/2005 10:30:00 19 2 25.6 12.6 18.8 2.1 25.6 13 18.3 2.2 23.3 12.6 325 10 311 165 -2 0 -1.9 -2.1 12/01/2005 10:40:00 17.2 2 22.9 11.8 17.1 2 22.9 11.5 16.8 2 21.4 11.1 325 10 307 165 -2 0 -1.9 -2.1 12/01/2005 10:50:00 14 1.8 19.5 9.1 14 1.9 19.5 8.4 13.3 1.6 19.1 9.5 327 12 315 165 -1.9 0 -1.7 -2.1 12/01/2005 11:00:00 13.7 1.7 18.3 9.5 13.6 1.6 18.3 9.1 13.1 1.8 18.7 8.4 321 11 305 165 -2 0 -1.9 -2.1 12/01/2005 11:10:00 13.3 1.6 20.2 8.8 13.1 1.6 18.7 8.4 12.7 1.7 17.6 8.8 322 10 316 165 -2.2 0 -1.9 -2.4 12/01/2005 11:20:00 12.3 1.7 17.9 8.4 12.3 1.7 17.9 8.4 11.9 1.7 16.8 8.4 324 11 321 165 -2 0 -1.9 -2.1 12/01/2005 11:30:00 13 1.8 19.5 8.8 13 1.8 19.9 9.1 12.3 1.7 19.1 8.8 319 12 311 165 -2 0 -1.9 -2.1 12/01/2005 11:40:00 11.9 1.4 16.1 8.8 11.9 1.4 16.1 8.4 10.9 1.6 16.4 7.2 314 9 303 165 -2.1 0 -1.9 -2.1 12/01/2005 11:50:00 10.8 1.5 14.5 7.6 10.7 1.5 14.9 7.2 10 1.4 14.1 6.1 320 16 312 165 -2 0 -1.9 -2.1 12/01/2005 12:00:00 9.9 1.2 13.3 7.6 9.9 1.2 13.3 7.2 9.5 1.3 13.3 6.5 329 13 343 165 -2 0 -1.9 -2.1 12/01/2005 12:10:00 9.8 1.6 15.6 6.5 9.8 1.7 15.6 6.5 9 1.5 13.7 5.7 315 13 301 165 -1.8 0 -1.7 -2.1 12/01/2005 12:20:00 10.2 1.3 15.3 7.2 10.1 1.3 15.3 7.2 9.3 1.3 13 6.1 316 11 306 165 -1.7 0 -1.4 -1.9 12/01/2005 12:30:00 8 1.5 12.6 4.9 7.9 1.7 12.6 4.2 7.6 1.1 11.1 4.2 321 17 288 165 -1.5 0.1 -1.4 -1.7 12/01/2005 12:40:00 9.6 1.6 14.1 5.3 9.5 1.7 14.1 4.6 8.5 1.7 13.7 4.6 317 12 318 165 -1.6 0 -1.2 -1.9 12/01/2005 12:50:00 9.6 1.8 14.5 5.3 9.2 2 14.5 5.3 9.2 1.9 14.9 4.6 337 14 304 165 -1.6 0 -1.4 -1.7 12/01/2005 13:00:00 9.5 1.7 15.3 4.2 9.3 1.6 14.9 3.8 9 1.6 14.1 5.3 331 14 300 165 -1.6 0 -1.4 -1.7 12/01/2005 13:10:00 10.6 1.7 15.6 6.1 10.6 1.7 16.1 6.5 9.9 1.5 15.3 6.1 315 13 295 165 -1.7 0 -1.4 -1.9 12/01/2005 13:20:00 11.2 1.9 16.8 6.5 11.2 1.9 16.8 6.8 10.3 1.8 14.9 5.7 317 12 317 165 -1.9 0 -1.7 -1.9 12/01/2005 13:30:00 10.8 2.2 16.1 6.1 10.7 2.1 15.6 6.1 9.7 1.8 14.5 6.1 313 12 293 165 -1.9 0.1 -1.7 -2.1 12/01/2005 13:40:00 9.9 2.4 15.6 4.2 9.8 2.4 15.6 4.2 8.9 2.2 16.1 3.8 312 11 300 165 -2 0 -1.9 -2.1 12/01/2005 13:50:00 9 1.7 13.3 5.3 8.8 1.8 13 4.2 8.5 1.6 13 4.6 321 17 310 165 -1.8 0 -1.7 -1.9 12/01/2005 14:00:00 9.9 1.7 14.1 6.5 9.8 1.7 13.7 5.7 8.8 1.5 13.3 4.9 313 12 295 165 -1.8 0.1 -1.4 -2.1 12/01/2005 14:10:00 10.7 1.3 15.3 7.2 10.6 1.3 15.3 7.6 9.5 1.5 14.1 4.6 312 10 299 165 -2 0 -1.9 -2.4 12/01/2005 14:20:00 9.9 1.8 16.4 6.5 9.8 1.8 16.4 6.1 9.1 1.8 16.8 5.3 320 13 309 165 -1.8 0.1 -1.7 -2.1 12/01/2005 14:30:00 10.8 1.6 15.3 6.8 10.7 1.6 15.6 6.1 10.1 1.5 14.5 6.5 321 13 311 165 -2 0 -1.9 -2.1 12/01/2005 14:40:00 8.8 1.3 13 5.3 8.6 1.4 13.7 4.9 8.1 1.3 13.3 4.9 325 17 309 165 -2 0 -1.9 -2.1 12/01/2005 14:50:00 9.7 1.3 13.7 6.1 9.7 1.3 13.3 6.5 8.8 1.5 13.7 4.9 317 13 310 165 -2 0 -1.9 -2.1 12/01/2005 15:00:00 10.3 1.5 14.9 6.1 10.2 1.5 14.9 5.7 9.3 1.3 13.7 5.7 315 8 298 165 -2.1 0 -1.9 -2.1 12/01/2005 15:10:00 8.9 1.5 13 4.6 8.7 1.5 13.3 4.2 8.5 1.5 13.7 4.2 329 16 341 165 -2.2 0 -2.1 -2.4 12/01/2005 15:20:00 8.8 1.3 11.8 4.9 8.7 1.3 11.5 4.2 8.1 1.2 11.5 4.2 320 15 315 165 -2.5 0.2 -2.1 -3 12/01/2005 15:30:00 9.1 1.5 13.7 5.7 8.9 1.6 14.1 5.3 8.3 1.4 13 3.8 326 16 305 165 -3.1 0 -2.8 -3.3 12/01/2005 15:40:00 9.4 1.1 12.6 6.5 9.4 1.1 12.2 6.5 8.4 1.2 11.5 5.7 321 15 298 165 -3.1 0 -2.8 -3.3 12/01/2005 15:50:00 7.8 1.5 12.6 3.8 7.6 1.5 12.6 4.2 7.4 1.4 11.5 4.6 333 15 336 165 -3.2 0 -3 -3.5 12/01/2005 16:00:00 8.5 1.5 13.7 5.3 7.7 1.7 13.7 3.8 8.4 1.4 13 5.3 345 14 350 165 -3.2 0 -3 -3.3 12/01/2005 16:10:00 8.6 1.3 12.6 5.3 8.4 1.5 12.6 4.6 8.5 1.4 12.2 5.3 340 10 325 165 -3.4 0 -3.3 -3.5 12/01/2005 16:20:00 8 1.2 11.5 5.3 7.5 1.3 12.2 4.2 7.9 1.1 10.7 4.2 342 13 343 165 -3.5 0 -3.3 -3.5 12/01/2005 16:30:00 6.5 1 9.9 4.6 6.1 1 9.9 3.4 6.3 0.9 9.1 4.2 337 13 2 165 -3.6 0 -3.5 -3.7 12/01/2005 16:40:00 8.7 1.2 11.8 5.3 8 1.2 10.7 4.6 8.2 1.2 11.5 5.7 341 15 359 165 -3.8 0 -3.5 -3.9 12/01/2005 16:50:00 9.7 1.5 13.3 6.1 9.3 1.7 13.7 5.3 9 1.5 13 5.7 329 18 317 165 -3.7 0 -3.5 -3.9 12/01/2005 17:00:00 9.7 1.3 13 6.5 9.6 1.3 13.3 6.1 9.4 1.3 12.6 5.7 328 12 307 165 -3.8 0.1 -3.5 -3.9 12/01/2005 17:10:00 10.9 1.6 16.8 6.5 10.8 1.7 16.4 7.2 10.2 1.6 16.1 6.5 323 13 310 165 -3.7 0 -3.5 -3.9 12/01/2005 17:20:00 11.9 1.7 17.6 8 11.8 1.7 17.9 6.5 11.4 1.8 17.9 6.5 322 12 335 165 -3.5 0 -3.3 -3.5 12/01/2005 17:30:00 10.4 1.1 13.3 8 10.4 1.1 13.7 7.6 9.7 1.3 13 5.3 316 8 314 165 -3.6 0 -3.5 -3.7 12/01/2005 17:40:00 11.5 1.2 14.9 9.1 11.4 1.2 14.9 8.8 10.3 1.3 13.7 6.5 314 8 314 165 -3.7 0 -3.5 -3.9 12/01/2005 17:50:00 11.8 1.2 15.3 8.8 11.7 1.2 14.9 8.8 11 1.3 13.7 7.6 315 7 310 165 -3.6 0 -3.5 -3.5 12/01/2005 18:00:00 12.3 1 14.5 9.1 12.2 1 14.5 9.1 11.5 1.2 13.7 8.4 314 6 310 165 -3.6 0 -3.5 -3.7 12/01/2005 18:10:00 10.9 1.2 14.5 8.4 10.8 1.2 14.5 7.6 10.6 1.3 14.5 6.8 318 6 319 165 -3.6 0 -3.5 -3.7 12/01/2005 18:20:00 11.3 1.4 15.6 7.6 11.2 1.4 15.6 7.2 10.6 1.5 14.5 7.2 316 6 319 165 -3.6 0 -3.5 -3.9 12/01/2005 18:30:00 11 1 13.7 8.4 10.9 1 13.7 8.4 10.4 1 13.3 8 316 6 304 165 -3.9 0 -3.5 -4.2 12/01/2005 18:40:00 12.5 1.1 16.1 9.9 12.4 1.1 16.1 9.9 12.1 1.3 15.3 8.8 318 6 316 165 -3.8 0.1 -3.5 -4.2 12/01/2005 18:50:00 11.8 0.9 15.3 9.5 11.7 0.9 14.9 9.9 11.4 1 14.1 7.6 318 6 315 165 -3.8 0 -3.5 -3.9 12/01/2005 19:00:00 12.8 1 16.4 10.3 12.7 1 16.1 9.5 12.5 1.1 16.1 8.8 318 5 325 165 -3.7 0 -3.5 -3.9 12/01/2005 19:10:00 12 1.3 15.6 8.8 11.9 1.3 15.6 8.8 11.7 1.3 14.9 8.4 319 6 309 165 -3.6 0 -3.5 -3.7 12/01/2005 19:20:00 12.4 1.3 15.6 9.5 12.4 1.3 15.6 9.5 12.2 1.5 16.1 8.4 322 7 315 165 -3.7 0 -3.5 -3.9 12/01/2005 19:30:00 14.2 1.5 17.9 11.1 14 1.5 17.9 10.7 13.8 1.5 17.9 8.8 321 7 316 165 -3.7 0 -3.5 -3.9 12/01/2005 19:40:00 14.8 1.2 17.9 10.7 14.7 1.2 17.6 10.7 13.9 1.5 17.6 8.8 315 6 312 165 -3.6 0 -3.5 -3.7 12/01/2005 19:50:00 13.8 1.5 18.3 10.7 13.7 1.5 17.9 10.7 12.6 1.6 17.6 8.8 312 7 310 165 -3.7 0 -3.5 -3.7 12/01/2005 20:00:00 13.4 1.3 17.2 9.5 13.3 1.3 16.8 9.5 12 1.5 15.3 8 311 6 304 165 -3.7 0 -3.5 -3.9 12/01/2005 20:10:00 13.3 1.3 17.2 10.7 13.2 1.3 16.4 10.3 12.3 1.2 16.1 9.5 314 6 319 165 -3.6 0 -3.5 -3.7 12/01/2005 20:20:00 13.9 1.4 17.9 10.7 13.8 1.4 17.9 10.7 13.3 1.3 17.2 9.5 320 8 310 165 -3.7 0 -3.5 -3.9 12/01/2005 20:30:00 13.8 1.7 17.2 8.8 13.6 1.7 17.2 9.1 13.2 1.6 17.2 8.8 322 9 326 165 -3.7 0 -3.5 -3.7 12/01/2005 20:40:00 13.1 1.5 16.4 8.4 13 1.5 16.4 8.8 12.4 1.6 16.1 8 319 9 325 165 -3.6 0 -3.3 -3.7 12/01/2005 20:50:00 14 1.1 16.8 10.3 13.9 1.2 16.4 10.3 12.8 1.5 17.9 9.1 313 6 298 165 -3.6 0 -3.5 -3.7 12/01/2005 21:00:00 13.6 1.5 16.4 9.9 13.5 1.4 16.1 9.9 12.7 1.5 16.1 8.8 315 6 311 165 -3.6 0 -3.5 -3.9 12/01/2005 21:10:00 15.6 1.2 20.2 13 15.5 1.2 19.9 12.6 14.6 1.7 18.3 9.5 315 7 303 165 -3.4 0 -3.3 -3.5 12/01/2005 21:20:00 14.9 1.4 17.9 11.5 14.7 1.4 18.3 11.5 13.6 1.7 17.6 8.8 312 5 311 165 -3.4 0 -3.3 -3.5 12/01/2005 21:30:00 14.8 1.3 17.9 11.5 14.7 1.3 17.9 11.5 13.8 1.4 18.3 9.9 315 6 308 165 -3.5 0 -3.3 -3.5 12/01/2005 21:40:00 14.4 1.5 18.3 11.1 14.3 1.5 18.3 10.7 13.3 1.6 17.9 8.8 313 7 308 165 -3.5 0 -3.3 -3.5 12/01/2005 21:50:00 14.9 1.4 18.7 9.9 14.8 1.4 18.7 10.3 13.2 1.6 17.6 8.4 311 6 302 165 -3.3 0 -3.3 -3.5 12/01/2005 22:00:00 16.3 1.2 19.5 12.2 16.1 1.2 19.5 12.2 15.2 1.4 19.9 11.1 314 4 313 165 -3.2 0 -3 -3.3 12/01/2005 22:10:00 16.8 1 19.1 12.6 16.7 1.1 18.7 12.6 16.1 1.2 18.7 12.6 316 4 313 165 -3.3 0 -3 -3.5 12/01/2005 22:20:00 17.2 0.7 19.1 14.9 17.1 0.7 19.1 14.1 16.7 0.9 19.5 13.7 317 4 317 165 -3.4 0 -3.3 -3.5 12/01/2005 22:30:00 15.8 1 18.7 13.3 15.7 1 18.7 13.3 15.6 1.2 19.5 12.2 319 5 323 165 -3.5 0 -3.3 -3.5 12/01/2005 22:40:00 15.5 1.1 17.9 12.6 15.5 1.1 17.9 12.6 14.6 1.2 17.2 11.1 314 6 309 165 -3.6 0 -3.5 -3.5 12/01/2005 22:50:00 13.1 1.1 16.1 9.9 13 1.1 15.6 9.9 12.1 1.3 15.3 8.4 314 7 311 165 -3.6 0 -3.5 -3.7 12/01/2005 23:00:00 13.1 1.2 16.8 10.3 13 1.2 16.4 10.3 12.8 1.3 16.8 9.9 322 6 327 165 -3.6 0 -3.5 -3.7 12/01/2005 23:10:00 13.7 1.5 17.6 9.5 13.6 1.5 17.9 9.9 13.2 1.4 17.2 9.1 320 8 307 165 -3.6 0 -3.3 -3.9 12/01/2005 23:20:00 16.3 1.3 19.5 13 16.2 1.3 19.5 12.6 15.6 1.7 20.2 11.5 317 6 305 165 -3.5 0 -3.3 -3.5 12/01/2005 23:30:00 15.7 1.2 19.1 12.6 15.6 1.2 19.1 12.2 15.3 1.3 19.1 11.8 320 6 319 165 -3.4 0 -3 -3.5 12/01/2005 23:40:00 14.6 1.3 17.6 11.1 14.5 1.3 17.6 10.7 14.2 1.3 16.8 10.3 318 6 316 165 -3.4 0 -3.3 -3.5 12/01/2005 23:50:00 12.7 1.5 17.2 8.8 12.6 1.5 17.9 8.8 12.5 1.6 16.8 7.6 320 6 312 165 -3.2 0 -3 -3.3 12/02/2005 00:00:00 9.2 1.4 12.6 7.2 9.1 1.4 12.2 6.8 8.7 1.7 12.6 5.3 315 7 314 165 -3.4 0.1 -3.3 -3.7 12/02/2005 00:10:00 7.9 0.8 9.9 5.7 7.9 0.8 9.9 5.7 6.5 1.1 9.5 4.2 306 5 309 165 -3.8 0 -3.5 -3.9 12/02/2005 00:20:00 8.9 0.6 10.3 7.2 8.8 0.6 10.3 7.2 6.5 0.8 8.8 4.6 304 4 307 165 -3.9 0 -3.9 -4.2 12/02/2005 00:30:00 9.5 0.6 11.1 7.6 9.4 0.6 10.7 7.2 8.7 0.8 10.7 6.1 313 5 310 165 -3.8 0.1 -3.5 -4.2 12/02/2005 00:40:00 9.1 0.9 11.5 6.8 8.9 0.9 11.1 6.5 8.5 0.9 9.9 6.1 317 8 319 165 -3.8 0 -3.5 -4.2 12/02/2005 00:50:00 9.4 0.6 11.1 7.6 9.4 0.7 11.5 7.6 7.8 0.9 10.3 5.7 308 5 308 165 -3.7 0 -3.5 -3.9 12/02/2005 01:00:00 9.8 0.5 11.1 8 9.8 0.5 11.1 8 8 0.8 10.3 4.9 308 3 305 165 -3.8 0 -3.7 -3.9 12/02/2005 01:10:00 9.1 0.6 10.7 7.6 9 0.6 10.7 7.6 7.7 0.7 9.5 5.7 309 4 309 165 -3.9 0 -3.5 -3.9 12/02/2005 01:20:00 9.7 0.6 11.5 8.4 9.6 0.6 11.5 8.4 8.8 0.8 11.1 6.8 312 4 307 165 -3.9 0 -3.7 -4.2 12/02/2005 01:30:00 8.7 0.7 10.3 6.8 8.6 0.7 10.3 6.8 8 0.6 9.5 5.7 314 4 307 165 -3.9 0 -3.7 -4.2 12/02/2005 01:40:00 8.3 0.5 9.9 7.2 8.2 0.5 9.5 6.8 7.5 0.7 9.1 5.7 312 4 310 165 -4 0 -3.9 -4.2 12/02/2005 01:50:00 8 0.4 8.8 6.8 7.9 0.4 9.1 6.5 7.3 0.5 8.4 5.7 313 3 315 165 -4.2 0 -3.9 -4.4 12/02/2005 02:00:00 7 0.4 8 5.7 6.9 0.4 8 5.7 6 0.7 7.6 4.6 310 4 314 165 -4.2 0 -3.9 -4.4 12/02/2005 02:10:00 6.3 0.5 7.6 4.9 6.3 0.5 7.6 4.9 5 0.8 6.8 3.4 306 5 302 165 -4.1 0 -3.9 -4.4 12/02/2005 02:20:00 6.2 0.6 7.6 4.9 6.2 0.6 7.6 4.9 4.4 0.6 5.7 3 300 5 295 165 -4.2 0 -3.9 -4.4 12/02/2005 02:30:00 6.1 0.7 8 4.2 6.1 0.7 8 4.2 4.6 0.7 7.2 3 297 6 297 165 -3.9 0 -3.7 -4.4 12/02/2005 02:40:00 6.9 0.7 8.4 4.9 6.9 0.6 8.4 5.3 5.3 0.8 7.6 3.4 293 4 287 165 -3.9 0 -3.7 -4.2 12/02/2005 02:50:00 6.5 0.6 8.4 4.9 6.5 0.7 8.4 4.9 5.6 0.8 7.6 3.4 287 6 291 165 -3.8 0 -3.7 -3.9 12/02/2005 03:00:00 6 0.4 7.6 4.9 6 0.4 7.6 4.9 5.1 0.7 6.8 3.4 287 5 288 165 -4 0.1 -3.7 -4.2 12/02/2005 03:10:00 4.7 0.6 6.5 3.4 4.7 0.6 6.5 3.4 3.7 0.5 5.7 2.6 303 7 298 165 -4.2 0.1 -3.9 -4.4 12/02/2005 03:20:00 4.2 0.5 5.3 2.3 4.2 0.5 5.7 2.6 3.3 0.5 4.9 2.3 295 9 294 165 -4.2 0 -3.9 -4.4 12/02/2005 03:30:00 4.3 1 6.8 1.5 4.4 1.1 6.8 2.6 4 1 6.5 2.3 282 8 274 165 -4.3 0 -3.9 -4.4 12/02/2005 03:40:00 5.6 0.6 6.8 3.4 5.8 0.5 6.8 4.9 5.5 0.5 6.5 4.2 276 4 278 165 -4.2 0.1 -3.9 -4.4 12/02/2005 03:50:00 4.2 0.5 5.3 2.6 4.6 0.4 5.7 3.8 4.3 0.4 4.9 3.4 271 4 268 165 -4.2 0 -3.9 -4.4 12/02/2005 04:00:00 3.5 0.6 4.6 1.9 3.8 0.4 4.9 2.6 3.5 0.4 4.6 2.3 270 8 273 165 -4.2 0 -3.9 -4.4 12/02/2005 04:10:00 2.6 0.3 3.4 1.9 2.7 0.3 3.8 1.9 2.4 0.3 3.4 1.9 232 10 261 165 -4.3 0 -4.2 -4.4 12/02/2005 04:20:00 3.4 1 5.7 1.1 3.5 1.1 5.7 1.1 3.1 1 5.7 1.1 255 23 291 165 -4.2 0 -3.9 -4.4 12/02/2005 04:30:00 2.1 0.8 4.2 0.4 2.4 0.8 4.2 0.7 2 0.8 4.2 0.4 257 22 279 165 -4.3 0 -3.9 -4.4 12/02/2005 04:40:00 1.8 0.8 3.8 0.4 2.1 1 4.6 0.4 1.7 1 4.6 0.4 252 22 255 165 -4.3 0 -4.2 -4.4 12/02/2005 04:50:00 3.3 0.5 4.2 1.9 3.7 0.3 4.6 3 3.3 0.4 4.2 1.9 271 6 270 165 -4.3 0 -4.2 -4.4 12/02/2005 05:00:00 3.1 0.5 4.6 1.9 3.6 0.4 4.2 2.6 3.4 0.4 4.2 2.6 256 8 248 165 -4.3 0 -4.2 -4.4 12/02/2005 05:10:00 3.5 0.6 4.9 1.9 3.8 0.5 4.9 2.6 3.6 0.5 4.9 2.3 248 12 238 165 -4.2 0.1 -3.9 -4.4 12/02/2005 05:20:00 3.7 0.6 5.3 2.3 4.5 0.6 5.7 3 4.1 0.6 5.7 2.6 268 7 280 165 -3.9 0 -3.7 -4.2 12/02/2005 05:30:00 3.3 0.5 4.9 1.9 3.5 0.5 5.7 2.3 3.4 0.5 5.3 1.9 243 16 244 165 -4.3 0 -3.9 -4.4 12/02/2005 05:40:00 4 1 6.1 1.9 4.5 0.9 6.5 2.3 4.2 0.8 5.7 2.3 262 11 243 165 -4 0 -3.9 -4.2 12/02/2005 05:50:00 5.7 0.9 7.6 3 5.8 0.8 7.6 3.4 5.3 0.9 7.6 3 280 7 276 165 -4 0 -3.9 -4.2 12/02/2005 06:00:00 6.2 0.5 7.6 4.9 6.3 0.5 7.6 4.9 5.6 0.7 7.6 3.4 285 5 282 165 -3.7 0.1 -3.5 -3.9 12/02/2005 06:10:00 6.1 0.8 7.6 4.6 6.1 0.7 7.6 4.6 4.7 0.7 6.5 3 293 4 294 165 -3.4 0 -3.3 -3.5 12/02/2005 06:20:00 5.4 0.5 6.5 3.8 5.4 0.5 6.5 3.8 4.3 0.8 6.1 2.3 293 6 295 165 -3.4 0 -3.3 -3.5 12/02/2005 06:30:00 3.9 0.4 4.9 3 3.9 0.4 4.9 3 3.1 0.6 4.6 1.9 291 4 291 165 -3.5 0.1 -3.3 -3.5 12/02/2005 06:40:00 3.1 0.3 4.2 2.3 3 0.3 4.2 2.3 2.4 0.4 3.4 1.1 303 6 296 165 -3.7 0 -3.5 -3.7 12/02/2005 06:50:00 2.9 0.3 3.8 2.3 2.9 0.3 3.8 2.3 2.5 0.4 3.4 1.5 308 7 311 165 -3.7 0 -3.5 -3.9 12/02/2005 07:00:00 3.4 0.3 4.2 2.6 3.4 0.4 4.2 2.3 2.9 0.4 3.8 1.9 307 5 307 165 -3.7 0 -3.5 -3.9 12/02/2005 07:10:00 3.8 0.2 4.6 3 3.8 0.2 4.6 3 2.7 0.4 3.8 1.5 301 5 303 165 -3.6 0 -3.5 -3.7 12/02/2005 07:20:00 4 0.4 5.3 3.4 4 0.4 4.9 3 3.3 0.7 4.6 1.9 293 8 297 165 -3.5 0 -3.3 -3.7 12/02/2005 07:30:00 4.5 0.6 5.7 2.6 4.5 0.6 5.7 2.6 3.6 0.5 4.9 2.6 306 7 297 165 -3.7 0 -3.3 -3.9 12/02/2005 07:40:00 4.9 0.4 6.1 3.8 4.9 0.4 6.1 3.8 3.8 0.6 5.3 2.6 305 5 309 165 -3.9 0 -3.7 -4.2 12/02/2005 07:50:00 4.9 0.5 6.5 3.8 4.9 0.5 6.5 3.8 3.7 0.6 5.7 2.6 299 6 291 165 -4.2 0.1 -3.9 -4.2 12/02/2005 08:00:00 4.5 0.5 6.1 3 4.5 0.5 5.7 3.4 3.7 0.5 4.6 2.6 303 6 294 165 -4.3 0 -4.2 -4.4 12/02/2005 08:10:00 4.7 0.3 5.7 4.2 4.7 0.3 5.3 4.2 3.8 0.5 4.9 2.6 304 3 302 165 -4.5 0.1 -4.2 -4.6 12/02/2005 08:20:00 5.9 0.5 7.2 4.9 5.9 0.5 7.2 4.6 4.2 0.6 6.5 3 297 4 296 165 -4.7 0 -4.6 -4.8 12/02/2005 08:30:00 6.3 0.6 8 4.9 6.4 0.7 8 4.9 5.5 1 8.4 3 288 6 282 165 -4.9 0 -4.6 -5 12/02/2005 08:40:00 7.2 0.8 8.8 4.9 7.2 0.7 8.8 4.9 5.3 0.8 7.6 3.4 296 6 297 165 -5.2 0.1 -4.8 -5.5 12/02/2005 08:50:00 8.1 0.6 9.9 6.8 8 0.6 9.5 6.5 7.2 0.6 8.4 4.9 311 5 301 165 -5.4 0 -5.3 -5.7 12/02/2005 09:00:00 8.8 0.6 10.3 7.6 8.7 0.6 10.3 7.2 8.2 0.7 10.3 6.1 314 5 323 165 -5.5 0 -5.3 -5.7 12/02/2005 09:10:00 8.3 0.8 9.9 6.1 8.2 0.8 9.9 5.7 7.6 0.8 9.5 5.3 313 5 315 165 -5.3 0.1 -5.3 -5.5 12/02/2005 09:20:00 8.9 0.8 11.1 6.8 8.8 0.9 11.1 6.8 8 0.9 11.1 5.3 312 6 312 165 -5.3 0 -5 -5.5 12/02/2005 09:30:00 9.7 1 12.2 6.5 9.6 1 12.2 6.5 8.5 1.1 12.2 5.7 310 6 312 165 -5.2 0 -5 -5.3 12/02/2005 09:40:00 9 1 11.5 6.8 8.9 1 11.5 6.8 8.2 1.2 11.1 4.9 313 7 307 165 -5.4 0 -5 -5.5 12/02/2005 09:50:00 8.7 0.7 10.7 6.1 8.6 0.7 10.7 6.8 8.3 1 10.3 5.3 315 7 311 165 -5.6 0.1 -5.5 -5.7 12/02/2005 10:00:00 8.8 0.9 11.1 6.5 8.8 0.9 11.1 6.5 7.7 1 10.3 5.7 308 7 305 165 -5.6 0 -5.5 -5.7 12/02/2005 10:10:00 8.5 0.8 10.7 6.5 8.4 0.8 11.1 6.5 6.6 0.9 9.1 4.6 301 7 301 165 -5.6 0 -5.5 -5.7 12/02/2005 10:20:00 8.8 0.9 11.1 6.1 8.8 0.9 11.1 6.1 6.9 0.9 9.5 4.6 304 6 304 165 -5.8 0.1 -5.5 -5.7 12/02/2005 10:30:00 7.1 1.1 9.5 4.6 7.1 1.1 9.5 4.2 5.8 0.9 8.4 3.8 300 8 299 165 -5.8 0 -5.7 -5.9 12/02/2005 10:40:00 6.4 1.2 9.9 3.4 6.3 1.2 9.9 3.8 5.2 1.1 9.1 3 298 9 305 165 -5.7 0 -5.5 -5.9 12/02/2005 10:50:00 7.6 1 10.3 4.9 7.5 1 10.3 4.9 6.3 1.1 9.1 3.8 294 9 310 165 -5.5 0 -5.5 -5.7 12/02/2005 11:00:00 10.2 1.5 14.9 6.1 10.1 1.5 14.5 6.5 8.3 1.5 12.6 4.6 297 8 291 165 -5.8 0.1 -5.5 -6.1 12/02/2005 11:10:00 10.2 1.3 13.3 5.7 10.2 1.3 13.7 5.3 8.8 1.6 12.6 4.9 298 11 287 165 -6.2 0.1 -5.9 -6.4 12/02/2005 11:20:00 8.7 1.6 11.8 4.2 8.6 1.5 11.5 4.6 8.1 1.7 11.1 3 319 10 321 165 -6.1 0.1 -5.7 -6.6 12/02/2005 11:30:00 6.9 1.6 11.1 3.4 6.4 1.6 11.8 3 6.4 1.5 10.3 3.4 331 23 310 165 -5.9 0.2 -5.5 -6.1 12/02/2005 11:40:00 6.3 1.4 10.7 3 5.6 1.4 9.1 2.3 6.3 1.3 9.9 3 354 22 14 165 -5.8 0 -5.5 -5.7 12/02/2005 11:50:00 6.5 1.4 9.9 3.4 6.1 1.7 9.9 2.6 6.1 1.4 9.9 3 332 22 297 165 -5.8 0.1 -5.5 -6.1 12/02/2005 12:00:00 6.2 1.7 10.7 2.3 5.9 1.7 10.7 2.3 5.7 1.7 11.5 2.6 332 15 328 165 -6.1 0 -5.9 -6.4 12/02/2005 12:10:00 6.7 1.1 10.7 3.8 6.6 1.2 10.3 3.4 6.1 1 10.3 3.8 319 13 302 165 -6.1 0 -5.9 -6.1 12/02/2005 12:20:00 5.8 1.3 9.5 3 5.5 1.5 9.1 2.3 5.4 1.4 9.1 2.3 325 17 327 165 -5.9 0.1 -5.5 -6.1 12/02/2005 12:30:00 4.7 1.4 8.4 2.3 4.5 1.5 8.4 1.5 4.2 1.2 7.6 1.9 332 17 303 165 -5.5 0.1 -5.3 -5.7 12/02/2005 12:40:00 5.5 1.4 9.5 2.3 5.3 1.5 9.5 1.9 4.8 1.2 8 1.9 322 19 312 165 -5.6 0.2 -5 -5.9 12/02/2005 12:50:00 5.7 1.6 9.5 1.9 5.5 1.6 9.5 1.9 5 1.5 8 0.7 321 14 324 165 -5.4 0.2 -5 -5.7 12/02/2005 13:00:00 5.8 1.4 8.8 1.9 5.6 1.5 8.8 1.9 5.4 1.5 9.5 2.3 327 18 319 165 -5.7 0.1 -5.5 -5.9 12/02/2005 13:10:00 5.1 1.5 8.4 1.9 4.8 1.7 8.4 1.5 4.5 1.7 8 0.7 338 15 338 165 -5.3 0.1 -5 -5.7 12/02/2005 13:20:00 6.5 1.5 9.5 3.8 6.2 1.7 9.5 2.6 6.1 1.5 9.5 3 335 17 314 165 -5.5 0.1 -5 -5.7 12/02/2005 13:30:00 6.9 1.1 9.9 4.2 6.5 1.4 9.5 2.6 6.3 1.1 9.5 3.8 337 18 328 165 -5.8 0.1 -5.5 -5.9 12/02/2005 13:40:00 7.1 1.2 9.9 3.8 6.9 1.2 9.9 3.8 6.7 1.3 9.5 3.4 325 10 325 165 -6 0 -5.7 -6.1 12/02/2005 13:50:00 8.7 0.9 11.1 6.1 8.5 0.9 10.7 5.7 7.9 1 10.7 5.3 316 7 307 165 -6.2 0.1 -6.1 -6.6 12/02/2005 14:00:00 7.2 1.2 10.7 4.2 7.1 1.2 10.3 4.2 6.4 1.1 9.5 3.4 315 9 310 165 -6.3 0 -6.1 -6.6 12/02/2005 14:10:00 9.1 1.8 12.6 4.6 9 1.8 12.6 4.9 7.3 1.3 11.1 3.8 301 9 290 165 -6.7 0.2 -6.1 -7 12/02/2005 14:20:00 10.8 1 13 7.2 10.7 1 13.3 8 9.1 1.2 12.2 5.7 308 8 299 165 -7.2 0 -6.8 -7.2 12/02/2005 14:30:00 10.5 1.3 13.3 6.1 10.4 1.3 13.7 6.1 8.6 1.3 12.2 4.6 306 7 300 165 -7.3 0 -7 -7.4 12/02/2005 14:40:00 9.7 1.7 13.3 5.7 9.7 1.6 13 5.7 8.6 1.6 12.2 4.6 311 10 307 165 -7.3 0.1 -6.8 -7.4 12/02/2005 14:50:00 11.5 1.3 14.5 8 11.4 1.3 14.1 7.6 9.9 1.4 13 6.1 308 6 309 165 -7.6 0 -7.4 -7.9 12/02/2005 15:00:00 12.5 1.3 15.6 8 12.4 1.3 15.3 7.6 9.5 1.3 14.1 6.5 300 7 303 165 -8 0 -7.6 -8.1 12/02/2005 15:10:00 12.8 1.3 16.1 9.1 12.8 1.3 16.1 8.8 10.2 1.5 14.5 6.8 301 7 298 165 -8.2 0 -8.1 -8.5 12/02/2005 15:20:00 13.4 1.6 18.7 9.9 13.3 1.6 18.7 9.9 10.4 1.5 14.5 6.8 298 8 300 165 -8.5 0 -8.5 -8.7 12/02/2005 15:30:00 16.3 1.3 19.1 11.1 16.2 1.4 19.5 11.1 13.1 1.8 18.7 8.8 293 5 295 165 -8.5 0 -8.3 -8.5 12/02/2005 15:40:00 15.8 1 18.7 13 15.9 1 18.7 13 13.7 1.9 19.1 9.1 290 5 290 165 -8.5 0 -8.5 -8.5 12/02/2005 15:50:00 14.4 1.6 19.5 9.9 14.4 1.6 19.5 9.9 11.6 1.8 17.2 7.6 292 6 287 165 -8.6 0 -8.5 -8.7 12/02/2005 16:00:00 14.4 1.3 17.9 9.5 14.4 1.4 18.3 9.5 12.4 2 18.7 6.1 289 7 281 165 -8.7 0 -8.5 -8.9 12/02/2005 16:10:00 12.1 1.3 14.5 8 12 1.4 14.5 7.6 9.6 1.5 14.5 5.7 296 8 297 165 -8.8 0 -8.7 -8.9 12/02/2005 16:20:00 11.1 1.3 14.5 7.6 11 1.3 14.1 7.6 9 1.7 13.7 5.7 293 8 292 165 -8.9 0 -8.7 -9.1 12/02/2005 16:30:00 12.5 1.8 16.8 8.8 12.5 1.8 16.4 8.8 9.9 1.9 15.3 6.1 297 7 299 165 -8.9 0 -8.9 -9.1 12/02/2005 16:40:00 12.4 1.7 16.4 9.1 12.4 1.7 16.4 8.4 10 1.7 14.5 6.1 294 7 288 165 -8.9 0.1 -8.9 -9.1 12/02/2005 16:50:00 13.7 1.1 17.2 10.3 13.8 1.1 16.8 9.9 12.4 2 16.8 7.2 285 7 291 165 -9.1 0 -8.9 -9.1 12/02/2005 17:00:00 13.9 1.1 16.8 10.7 13.9 1.1 16.8 9.9 11.5 1.7 15.6 8 290 6 295 165 -9.1 0 -8.9 -9.3 12/02/2005 17:10:00 12.7 1.5 16.1 8.4 12.6 1.6 16.1 8.4 9.6 1.7 14.1 6.1 296 7 297 165 -9.1 0 -8.9 -9.1 12/02/2005 17:20:00 11.3 1.1 14.5 8.4 11.2 1.1 14.1 8 8.8 1.4 13 6.1 296 6 291 165 -9.1 0 -8.9 -9.3 12/02/2005 17:30:00 12 1.2 14.5 9.1 12 1.2 14.5 9.1 9.2 1.3 12.6 6.1 294 6 301 165 -9.1 0 -8.9 -9.3 12/02/2005 17:40:00 11.3 1 14.9 8.8 11.3 1 14.9 8.8 8.7 1.5 14.5 5.7 294 7 292 165 -9.1 0 -8.9 -9.1 12/02/2005 17:50:00 12.6 1 16.1 9.9 12.6 1 15.6 9.9 9.7 1.5 13.7 6.1 296 7 307 165 -9.1 0 -8.9 -9.1 12/02/2005 18:00:00 11.5 1.3 14.5 8.4 11.4 1.3 14.5 8.4 9.9 1.5 14.5 6.5 305 9 303 165 -9.1 0 -9.1 -9.3 12/02/2005 18:10:00 11.2 1.5 14.1 7.6 11.1 1.5 14.1 7.6 9.4 1.7 13 5.7 305 7 304 165 -9.1 0 -8.9 -9.3 12/02/2005 18:20:00 12.5 1.5 16.4 8.8 12.4 1.5 16.4 9.5 10.2 1.3 14.5 6.8 305 7 296 165 -9.2 0 -9.1 -9.3 12/02/2005 18:30:00 13.6 1.2 16.8 9.5 13.5 1.2 16.8 9.1 11.1 1.5 15.6 8 306 6 310 165 -9.3 0 -9.1 -9.3 12/02/2005 18:40:00 12 1.2 16.1 8.8 11.9 1.2 16.1 8.8 10.1 1.5 14.9 6.8 307 7 307 165 -9.4 0 -9.3 -9.7 12/02/2005 18:50:00 12.7 1.7 17.9 8.8 12.6 1.7 17.9 8.4 10.5 1.8 17.6 6.5 301 9 317 165 -9.4 0 -9.3 -9.5 12/02/2005 19:00:00 10.8 1.5 14.1 7.2 10.7 1.5 14.5 6.8 8.6 1.7 14.5 5.3 298 9 296 165 -9.5 0 -9.3 -9.7 12/02/2005 19:10:00 13.7 1.7 17.2 7.6 13.6 1.8 17.2 8 11.2 1.9 16.1 6.5 299 10 291 165 -9.5 0.1 -9.3 -9.7 12/02/2005 19:20:00 13.1 1.8 17.6 9.9 13 1.7 17.6 9.5 10.5 1.7 15.6 6.8 298 8 290 165 -9.7 0 -9.7 -9.7 12/02/2005 19:30:00 14.1 2.1 18.3 9.1 14 2.1 18.7 8.8 11.2 1.8 16.4 5.7 300 9 294 165 -9.7 0 -9.7 -9.7 12/02/2005 19:40:00 14.5 2.2 19.5 10.3 14.4 2.2 19.5 9.9 11.4 1.8 16.4 7.2 300 8 303 165 -9.9 0 -9.7 -10 12/02/2005 19:50:00 14.9 2 20.6 9.9 14.9 2 20.2 9.9 12.4 1.8 17.9 8.4 302 9 293 165 -9.9 0 -9.7 -10 12/02/2005 20:00:00 15.5 1.5 19.5 11.5 15.4 1.6 19.5 11.5 12.5 1.8 17.2 8.8 301 9 291 165 -10 0 -9.7 -10.2 12/02/2005 20:10:00 16.2 1.6 20.6 10.7 16.2 1.7 20.6 10.7 13.8 2.1 19.5 9.1 303 7 301 165 -10.1 0 -9.7 -10.2 12/02/2005 20:20:00 17.4 1.8 21 11.5 17.4 1.8 21.4 11.1 13.9 2.2 21 8.8 294 8 282 165 -10.2 0 -10 -10.2 12/02/2005 20:30:00 15.5 1.7 18.7 11.5 15.5 1.8 18.7 11.1 12.2 2.2 19.5 8.4 296 7 290 165 -10.1 0 -10 -10.2 12/02/2005 20:40:00 13 1.7 16.8 8.4 12.9 1.7 16.8 9.1 10.5 1.9 16.4 4.9 300 9 312 165 -10.1 0 -9.7 -10.2 12/02/2005 20:50:00 14.1 1.7 19.5 10.3 14 1.7 19.5 10.3 11.8 2 18.7 7.2 304 7 300 165 -10.2 0 -10 -10.2 12/02/2005 21:00:00 14.2 1.5 17.9 11.1 14.2 1.5 17.6 10.7 11.6 1.7 16.1 7.6 302 7 287 165 -10.2 0 -10 -10.2 12/02/2005 21:10:00 15.1 1.6 20.6 11.1 15 1.6 20.6 11.1 12.2 1.9 18.3 7.2 300 7 298 165 -10.1 0 -10 -10.2 12/02/2005 21:20:00 15.1 1.5 19.9 11.1 15.1 1.5 19.5 11.5 12.5 1.9 17.6 8.8 301 7 305 165 -10.1 0 -10 -10.2 12/02/2005 21:30:00 15.9 1.4 19.5 11.8 15.8 1.4 19.5 12.2 12.5 1.9 17.9 8.4 301 6 302 165 -10.2 0 -10 -10.2 12/02/2005 21:40:00 15.4 1.3 18.3 9.9 15.4 1.3 18.7 10.3 12.2 1.9 17.6 8 298 7 296 165 -10.3 0 -10.2 -10.4 12/02/2005 21:50:00 16.3 1.2 19.5 13 16.3 1.2 19.1 13.3 12.5 1.5 17.6 8.8 296 6 286 165 -10.4 0 -10.4 -10.6 12/02/2005 22:00:00 16.7 1.1 19.1 13.3 16.8 1.2 19.5 13.3 12.7 1.3 16.8 9.9 299 5 298 165 -10.4 0 -10.2 -10.6 12/02/2005 22:10:00 15.7 1.5 19.1 12.2 15.6 1.5 19.1 11.8 12.5 1.7 16.8 8.4 302 5 296 165 -10.4 0 -10.2 -10.6 12/02/2005 22:20:00 15.8 1.3 18.3 11.5 15.8 1.3 18.3 12.2 12.3 1.7 18.3 8.4 298 6 292 165 -10.4 0 -10.2 -10.6 12/02/2005 22:30:00 15 1.3 18.3 10.3 15 1.4 18.3 10.3 11.8 1.5 16.4 8.8 297 7 287 165 -10.5 0 -10.2 -10.6 12/02/2005 22:40:00 15.8 1.5 18.7 10.3 15.7 1.5 19.1 10.7 12.8 2 19.5 8 294 9 290 165 -10.5 0 -10.4 -10.6 12/02/2005 22:50:00 13.8 2 18.7 9.9 13.7 2 18.7 9.9 12 1.8 17.2 8 308 7 309 165 -10.5 0 -10.4 -10.6 12/02/2005 23:00:00 14.2 2 19.1 8 14.1 2 18.7 8 12.6 2.4 18.7 7.6 309 7 307 165 -10.4 0 -10.4 -10.6 12/02/2005 23:10:00 14.8 1.7 19.9 11.1 14.7 1.7 19.9 11.1 12.9 2.1 17.9 8.4 306 7 308 165 -10.4 0 -10.2 -10.6 12/02/2005 23:20:00 15.9 2.1 20.6 9.9 15.8 2.1 20.2 10.3 13.4 2.3 18.7 8.8 306 8 307 165 -10.3 0 -10.2 -10.4 12/02/2005 23:30:00 12.8 1.8 17.2 8 12.7 1.7 16.8 8.4 11.1 2 16.8 6.5 307 11 300 165 -10.4 0 -10.2 -10.6 12/02/2005 23:40:00 13.3 2.3 18.7 8.4 13.3 2.4 19.1 8.4 11.7 2.7 19.5 6.1 309 11 316 165 -10.3 0 -10.2 -10.4 12/02/2005 23:50:00 16.6 2.2 21.8 10.3 16.4 2.2 22.1 9.9 14.1 2.4 21.8 7.2 305 8 310 165 -10.3 0 -10.2 -10.4 12/03/2005 00:00:00 12.1 3.1 21.8 5.7 12.1 3.1 21.4 5.7 9.9 2.8 19.9 4.2 300 12 306 165 -10.2 0 -10.2 -10.4 12/03/2005 00:10:00 9.1 2.9 15.6 1.9 9.1 3.1 15.6 1.5 7.7 2.7 14.9 0.7 302 19 288 165 -10.3 0 -10.2 -10.4 12/03/2005 00:20:00 8.2 2.6 15.3 1.9 8.1 2.7 15.3 1.1 7 2.5 13.3 1.5 312 15 310 165 -10.3 0 -10.2 -10.4 12/03/2005 00:30:00 8.6 1.8 14.1 4.2 8.5 1.8 13.3 3.8 7.4 1.8 12.2 3 304 13 297 165 -10.3 0 -10.2 -10.6 12/03/2005 00:40:00 12.8 2.2 17.9 7.6 12.7 2.2 18.3 7.6 11.5 2.4 17.9 6.1 296 14 273 165 -10.3 0 -10.2 -10.6 12/03/2005 00:50:00 12.9 1.7 16.4 9.1 13 1.7 16.8 9.1 11.7 2.1 16.1 6.8 287 8 273 165 -10.3 0 -10.2 -10.4 12/03/2005 01:00:00 12.4 1.7 17.2 8 12.4 1.6 16.4 7.6 10.5 1.7 15.6 6.1 293 9 282 165 -10.3 0 -10.2 -10.6 12/03/2005 01:10:00 14.4 2.1 18.7 8.4 14.2 2.1 18.7 8.8 11.6 2 18.3 6.8 302 8 302 165 -10.3 0 -10.2 -10.6 12/03/2005 01:20:00 17 2.4 22.1 10.3 17 2.4 22.1 10.7 14.6 2.3 19.5 9.1 307 7 308 165 -10.2 0 -10.2 -10.4 12/03/2005 01:30:00 18.7 1.6 22.1 14.1 18.6 1.6 22.6 13.7 15.7 2 21.4 11.5 306 7 304 165 -10.1 0 -10 -10.2 12/03/2005 01:40:00 18.2 2 22.9 13 18.1 2 22.9 13.3 14.7 2.4 21.8 9.1 304 6 307 165 -10 0.1 -9.7 -10.2 12/03/2005 01:50:00 16 1.5 19.9 10.7 15.9 1.5 19.9 11.1 12.9 1.7 17.9 8 302 7 303 165 -10.1 0 -10 -10.2 12/03/2005 02:00:00 15.7 1.3 19.1 12.2 15.6 1.3 19.5 11.8 13.2 1.8 18.7 8.8 306 7 303 165 -10.1 0 -10 -10.2 12/03/2005 02:10:00 15.9 1.2 19.5 12.2 15.8 1.3 19.9 12.2 12 1.4 15.6 8.8 299 6 295 165 -10 0 -9.7 -10.2 12/03/2005 02:20:00 17.3 1.5 21 13.3 17.2 1.5 21.4 13.3 13.2 1.4 17.2 9.9 301 5 296 165 -9.9 0 -9.7 -10 12/03/2005 02:30:00 17.5 2.1 22.1 13 17.4 2.1 22.1 12.2 14.9 2.5 20.2 10.3 305 6 307 165 -9.8 0 -9.7 -10 12/03/2005 02:40:00 19 1.2 22.1 16.1 18.9 1.2 21.8 15.6 16.1 2.2 20.6 11.1 307 4 310 165 -9.7 0 -9.5 -9.7 12/03/2005 02:50:00 18.8 1.3 21.8 14.5 18.8 1.3 21.8 14.5 16 1.8 21 11.5 307 5 309 165 -9.7 0 -9.5 -9.7 12/03/2005 03:00:00 17.8 1.3 21.4 14.9 17.7 1.3 21.4 14.9 14 1.9 19.5 9.9 304 4 301 165 -9.6 0 -9.3 -9.7 12/03/2005 03:10:00 15.9 1.3 19.5 12.2 15.8 1.3 19.9 12.2 12.6 1.7 16.4 8.4 306 5 302 165 -9.5 0 -9.3 -9.7 12/03/2005 03:20:00 13.9 0.8 16.1 11.5 13.9 0.9 16.1 11.8 10.8 1.5 14.5 8 302 6 295 165 -9.5 0 -9.3 -9.7 12/03/2005 03:30:00 13.8 1.2 16.8 10.7 13.8 1.2 17.2 10.3 10.2 1.5 14.1 6.8 303 4 302 165 -9.4 0 -9.3 -9.5 12/03/2005 03:40:00 14.4 1.3 17.2 11.5 14.4 1.3 17.2 11.1 10.3 1.6 15.3 7.6 301 5 307 165 -9.4 0 -9.1 -9.5 12/03/2005 03:50:00 15.9 1.4 18.7 11.5 15.8 1.4 19.1 11.5 11.2 1.5 15.6 8 300 4 305 165 -9.2 0 -9.1 -9.3 12/03/2005 04:00:00 15.3 1.1 17.9 11.5 15.3 1.2 17.9 11.5 11.2 1.2 15.3 8.4 299 5 300 165 -9.1 0 -9.1 -9.3 12/03/2005 04:10:00 14.2 1.1 17.2 11.1 14.2 1.2 16.8 10.7 9.9 1 12.6 7.6 300 3 297 165 -9.3 0 -9.1 -9.3 12/03/2005 04:20:00 13.8 1 15.6 10.3 13.8 1 16.1 10.7 10 1.2 13.7 7.6 298 5 302 165 -9.2 0 -9.1 -9.3 12/03/2005 04:30:00 13.8 1.1 16.4 9.9 13.8 1.1 16.4 9.9 10.4 1.2 14.5 8 298 5 298 165 -9.1 0 -8.9 -9.1 12/03/2005 04:40:00 13.6 1.1 15.6 10.7 13.5 1.1 16.1 10.7 9.7 1 13.3 7.2 302 4 308 165 -9.1 0 -8.9 -9.1 12/03/2005 04:50:00 12.4 1 14.9 9.9 12.3 1 14.9 10.3 8.7 1 11.8 6.1 300 5 296 165 -9.1 0 -8.9 -9.1 12/03/2005 05:00:00 11.7 0.9 14.5 9.5 11.8 0.9 14.5 9.5 9.9 1.2 13 7.2 290 5 295 165 -8.9 0 -8.7 -9.1 12/03/2005 05:10:00 11.5 0.7 13.3 9.1 11.5 0.7 13 9.1 10 1.1 13.3 6.5 289 4 298 165 -8.9 0 -8.7 -9.1 12/03/2005 05:20:00 12.6 0.8 14.9 10.7 12.7 0.8 14.5 10.7 10.3 1.2 13.7 7.6 292 4 291 165 -8.7 0 -8.5 -8.9 12/03/2005 05:30:00 13.5 1 15.6 10.3 13.6 1 16.1 10.3 11.4 1.7 15.3 7.2 290 4 288 165 -8.7 0 -8.5 -8.9 12/03/2005 05:40:00 13.4 0.6 14.9 11.8 13.4 0.6 15.3 11.8 10.8 1.6 14.9 6.5 292 4 284 165 -8.6 0 -8.5 -8.7 12/03/2005 05:50:00 13.4 1 16.1 10.3 13.4 1 16.1 10.3 9.8 1.3 14.5 6.8 303 5 304 165 -8.8 0 -8.5 -8.9 12/03/2005 06:00:00 13.7 0.9 16.1 11.1 13.7 0.8 16.1 11.1 10.9 1.5 14.5 7.6 306 4 301 165 -8.9 0 -8.5 -8.9 12/03/2005 06:10:00 13 0.9 15.3 9.9 12.9 1 15.3 9.9 10.1 1.3 13.7 6.8 305 5 304 165 -8.9 0 -8.7 -8.9 12/03/2005 06:20:00 10.5 1.7 13.7 6.1 10.3 1.7 14.1 6.1 7.6 1.9 11.5 1.5 299 6 297 165 -9 0.1 -8.7 -9.1 12/03/2005 06:30:00 4.7 1.7 8.4 1.1 4.6 1.7 8.4 0.4 3 1.3 6.5 0.4 295 23 328 165 -9.2 0 -9.1 -9.3 12/03/2005 06:40:00 2.5 1.2 7.2 0.4 2.4 1.2 6.8 0.4 1.9 1 4.9 0.4 350 94 283 165 -9.2 0 -9.1 -9.3 12/03/2005 06:50:00 1.3 0.8 3 0.4 1.2 0.7 3 0.4 1.4 0.7 3 0.4 122 41 91 165 -9.3 0 -9.1 -9.3 12/03/2005 07:00:00 2 1.2 4.6 0.4 2 1.1 4.6 0.4 1.8 0.9 4.6 0.4 208 76 309 165 -9.4 0 -9.3 -9.7 12/03/2005 07:10:00 3.7 0.8 6.1 1.9 3.9 0.8 6.5 2.6 3.5 0.8 6.1 1.9 260 19 276 165 -9.5 0.1 -9.3 -9.7 12/03/2005 07:20:00 5.5 1.3 7.6 2.3 5.9 1 7.6 3 5.5 1 7.6 3 276 11 279 165 -9.6 0.1 -9.3 -9.7 12/03/2005 07:30:00 6.8 0.4 8 5.7 6.7 0.4 7.6 5.7 5.2 0.6 6.8 3.8 299 6 295 165 -9.5 0 -9.3 -9.7 12/03/2005 07:40:00 6.7 0.6 8 4.9 6.5 0.6 8 4.9 5.6 0.7 7.6 4.2 308 5 305 165 -9.5 0 -9.3 -9.7 12/03/2005 07:50:00 4.7 1.3 8 1.9 4.6 1.3 8 1.9 4 1.3 7.2 0.7 311 9 313 165 -9.5 0.1 -9.3 -9.7 12/03/2005 08:00:00 3.1 1.2 7.2 0.7 3 1.2 6.5 0.4 2.1 1.1 6.5 0.4 293 26 300 165 -9.7 0 -9.5 -10 12/03/2005 08:10:00 6 1.2 8.4 3 6 1.2 9.1 3 4.5 1.3 8 1.5 305 10 319 165 -9.7 0.1 -9.3 -10 12/03/2005 08:20:00 7.9 1.2 11.1 4.6 7.8 1.2 10.3 4.2 6 1.3 9.5 2.6 303 9 291 165 -9.5 0 -9.3 -9.7 12/03/2005 08:30:00 8.5 1.3 11.8 4.9 8.4 1.2 11.5 5.3 6.7 1.4 11.5 2.6 307 8 317 165 -9.4 0 -9.3 -9.7 12/03/2005 08:40:00 9.6 1.1 12.2 6.8 9.5 1.1 11.8 6.5 8.1 1.1 11.1 5.3 306 6 302 165 -9.2 0.1 -9.1 -9.3 12/03/2005 08:50:00 9 1.4 12.6 4.9 9 1.3 12.6 4.6 7.7 1.3 10.7 4.2 308 9 296 165 -9.1 0 -8.9 -9.1 12/03/2005 09:00:00 10.3 1 13.3 6.8 10.2 1.1 13 6.5 8.6 1.5 12.6 4.6 306 9 318 165 -8.8 0 -8.5 -9.1 12/03/2005 09:10:00 7.4 1.5 11.1 3.8 7.4 1.5 11.5 3.8 6.2 1.3 11.5 3 300 12 295 165 -8.3 0.2 -8.1 -8.7 12/03/2005 09:20:00 8 1.3 11.5 4.9 8 1.3 11.1 4.6 7.2 1.4 11.5 3.8 296 11 286 165 -8.3 0.1 -8.1 -8.5 12/03/2005 09:30:00 7.6 1 10.3 4.9 7.6 1 10.3 4.9 6.6 1.2 9.9 3.8 295 8 300 165 -8.2 0 -8.1 -8.5 12/03/2005 09:40:00 7.2 1.5 10.7 4.6 7.1 1.5 10.3 4.6 6.3 1.3 10.3 3.8 306 13 291 165 -8.2 0.1 -8.1 -8.5 12/03/2005 09:50:00 10.6 1.7 14.5 6.1 10.6 1.7 14.5 6.1 8.4 1.3 12.2 4.9 304 7 294 165 -8.7 0 -8.3 -8.9 12/03/2005 10:00:00 11.3 1.2 14.9 7.6 11.3 1.1 14.9 7.6 9.6 1.3 13.7 6.1 308 8 302 165 -8.7 0.1 -8.3 -9.1 12/03/2005 10:10:00 11.3 0.9 13.7 9.1 11.3 0.9 13.7 9.1 10.2 1.3 13 6.8 312 6 312 165 -8.5 0.1 -8.1 -8.9 12/03/2005 10:20:00 10.7 1.1 14.1 8 10.6 1.1 13.7 8 9.3 1.3 13.3 6.1 309 8 309 165 -8.7 0.1 -8.5 -8.9 12/03/2005 10:30:00 10 1.2 12.2 6.1 9.8 1.2 12.2 6.1 8.3 1.1 11.1 5.7 308 7 297 165 -8.8 0 -8.5 -9.1 12/03/2005 10:40:00 8.8 1 11.1 6.1 8.7 1 11.1 6.1 7.4 1.2 10.3 4.6 308 8 310 165 -8.3 0.1 -8.1 -8.7 12/03/2005 10:50:00 9.3 0.9 11.1 6.8 9.2 0.9 11.1 6.8 7.2 0.9 10.3 5.3 298 7 293 165 -8.3 0.1 -8.1 -8.5 12/03/2005 11:00:00 10.2 0.9 12.2 7.6 10.1 0.9 12.2 7.6 7.3 1 11.8 4.9 299 5 298 165 -8.4 0 -8.1 -8.5 12/03/2005 11:10:00 10 1 13.3 6.8 9.9 1 13 6.8 7.2 1 10.3 4.9 300 4 297 165 -8.1 0.1 -7.9 -8.3 12/03/2005 11:20:00 9.3 1.2 12.6 6.1 9.2 1.2 12.2 6.1 6.9 1 10.3 4.2 300 5 307 165 -8.1 0 -8.1 -8.3 12/03/2005 11:30:00 7.8 0.7 9.5 6.1 7.7 0.6 9.1 6.5 5.9 0.8 8.8 4.2 297 5 304 165 -8.2 0 -8.1 -8.3 12/03/2005 11:40:00 7.6 0.6 9.5 5.7 7.5 0.6 9.9 6.1 5.8 0.8 8 3.8 303 7 306 165 -8.1 0.1 -7.9 -8.3 12/03/2005 11:50:00 7.5 1 9.9 5.3 7.4 1 9.9 4.9 6 1 9.5 3.8 305 6 297 165 -7.7 0 -7.4 -8.1 12/03/2005 12:00:00 8.1 1.1 11.1 6.1 8 1.1 10.7 6.1 6.6 1.1 9.1 4.2 306 9 304 165 -7.5 0.1 -7.2 -7.6 12/03/2005 12:10:00 7.8 1 11.1 6.1 7.7 0.9 10.7 5.7 6.1 1 9.5 4.2 300 8 297 165 -7.5 0.1 -7.2 -7.6 12/03/2005 12:20:00 8 0.8 9.9 5.7 7.9 0.8 9.5 5.3 6.1 1 8.8 4.2 303 6 302 165 -7.4 0.1 -7.2 -7.6 12/03/2005 12:30:00 8.1 0.7 9.9 6.1 8 0.7 9.9 5.7 6.7 1 9.5 4.2 309 5 313 165 -7.7 0 -7.4 -7.9 12/03/2005 12:40:00 7 0.7 8.8 4.9 7 0.7 8.8 4.6 5.6 0.9 8.4 3.4 305 6 311 165 -7.8 0 -7.6 -8.1 12/03/2005 12:50:00 7.1 0.8 8.8 4.9 7.1 0.8 8.8 4.6 5.8 1 8 3.8 301 9 301 165 -7.8 0 -7.6 -8.1 12/03/2005 13:00:00 7.7 0.7 9.5 5.7 7.6 0.7 9.1 5.7 6 0.9 8 4.2 304 6 306 165 -7.8 0 -7.6 -7.9 12/03/2005 13:10:00 6.6 0.6 8.4 5.3 6.4 0.7 8 4.9 6 0.7 7.6 3.8 313 7 302 165 -7.6 0 -7.4 -7.6 12/03/2005 13:20:00 6 0.9 8.4 4.2 5.8 0.9 8.4 3.8 5.8 1 8.8 3.8 323 8 323 165 -7.3 0.1 -6.8 -7.6 12/03/2005 13:30:00 7.6 0.8 9.5 5.7 7.4 0.8 9.1 5.3 6.9 0.7 9.1 5.3 315 6 305 165 -7.3 0.1 -6.8 -7.4 12/03/2005 13:40:00 8.1 0.9 10.3 5.3 8 0.9 10.3 4.9 6.8 1 9.5 4.2 308 6 307 165 -7.5 0 -7.2 -7.6 12/03/2005 13:50:00 7.5 1 9.9 4.6 7.4 0.9 9.5 4.6 5.7 0.9 8.4 3.4 298 6 310 165 -7.5 0 -7.4 -7.6 12/03/2005 14:00:00 8.1 1 10.7 4.9 8 1 10.7 5.3 6.5 1.2 9.9 4.2 294 7 292 165 -7.5 0 -7.4 -7.6 12/03/2005 14:10:00 8 1 10.3 4.6 8 1 9.9 4.9 6.7 1.3 9.5 3.8 291 7 292 165 -7.8 0 -7.4 -8.1 12/03/2005 14:20:00 8 0.7 10.3 5.7 8 0.7 9.9 5.7 6.9 1.1 9.5 4.2 291 6 291 165 -8.2 0.1 -7.6 -8.3 12/03/2005 14:30:00 8.5 1 12.2 5.7 8.5 1 12.2 5.7 6.7 1.2 11.1 3.8 294 5 292 165 -8 0 -7.9 -8.1 12/03/2005 14:40:00 9.6 1 11.5 6.5 9.4 0.9 11.5 6.1 7.5 1.2 11.1 4.6 294 5 294 165 -7.9 0 -7.6 -8.1 12/03/2005 14:50:00 9.7 0.8 11.5 7.2 9.5 0.8 11.5 6.8 7.7 1.1 10.7 4.2 296 7 304 165 -7.6 0 -7.4 -7.6 12/03/2005 15:00:00 9.1 1 11.8 6.5 8.9 1 11.5 6.5 7.1 1 9.5 4.6 300 5 303 165 -7.6 0 -7.4 -7.9 12/03/2005 15:10:00 9.2 1 11.8 6.5 9.2 1 11.5 6.5 6.9 1.1 11.1 4.6 302 6 294 165 -8 0 -7.6 -8.1 12/03/2005 15:20:00 9.6 0.9 13 7.2 9.5 0.9 12.6 6.8 7.6 1.1 11.1 4.9 300 7 306 165 -8 0 -7.6 -8.1 12/03/2005 15:30:00 9.3 1.1 12.2 6.8 9.2 1 11.8 6.5 7.4 1 9.9 4.9 303 8 305 165 -8 0.1 -7.6 -8.1 12/03/2005 15:40:00 9 0.7 11.5 7.2 8.9 0.7 11.1 6.8 6.7 0.9 9.9 4.2 300 5 303 165 -8.1 0 -7.9 -8.3 12/03/2005 15:50:00 8.4 1 11.1 6.1 8.4 1 11.5 6.1 6.9 1.2 11.1 4.2 298 7 287 165 -8 0 -7.9 -8.3 12/03/2005 16:00:00 6.7 1.2 10.3 3.4 6.7 1.2 9.9 3.4 5.6 1 8.8 3 302 11 302 165 -8.2 0 -8.1 -8.5 12/03/2005 16:10:00 5.5 1 8 1.9 5.6 1 8 2.6 4.9 1.1 7.6 1.9 285 9 287 165 -8.8 0 -8.5 -9.1 12/03/2005 16:20:00 5.7 1.1 8.8 3 5.7 1 8.8 3 5 1.1 8.4 2.3 297 13 282 165 -8.9 0.1 -8.3 -9.1 12/03/2005 16:30:00 6.6 1.2 9.1 3.8 6.5 1.2 9.1 3.8 5.8 1.5 9.9 3 298 13 305 165 -8.4 0 -8.3 -8.7 12/03/2005 16:40:00 7.6 1.2 11.1 4.9 7.6 1.2 11.1 4.6 6.2 1.4 10.7 3.4 297 8 287 165 -8.6 0.1 -8.3 -8.9 12/03/2005 16:50:00 8.1 1.4 11.1 4.6 8.1 1.4 11.5 4.6 7.3 1.2 11.1 4.6 300 17 280 165 -8.7 0 -8.5 -8.9 12/03/2005 17:00:00 3.6 0.9 6.1 1.1 3.6 0.9 6.1 1.5 3.3 1.2 6.5 0.7 310 12 330 165 -8.9 0.1 -8.5 -9.1 12/03/2005 17:10:00 3.8 2 7.2 0.4 3.7 2.1 7.2 0.4 2.9 1.7 6.1 0.4 297 18 314 165 -8.9 0 -8.7 -9.1 12/03/2005 17:20:00 7.2 0.9 9.1 4.6 7.2 0.9 9.1 4.6 5.7 1 8 3 294 6 299 165 -8.8 0 -8.5 -8.9 12/03/2005 17:30:00 8.4 0.9 10.3 5.7 8.3 0.9 10.3 5.7 6.8 1.1 9.5 3.8 295 8 295 165 -8.8 0.1 -8.5 -9.1 12/03/2005 17:40:00 7.8 1.2 11.8 3.8 7.8 1.2 11.8 3.8 6.8 1.3 10.3 3 292 7 314 165 -8.6 0 -8.3 -8.7 12/03/2005 17:50:00 7 1.5 11.1 3.8 7 1.5 10.7 3.8 6 1.3 9.9 2.6 293 12 291 165 -8.5 0 -8.3 -8.5 12/03/2005 18:00:00 8.3 1.4 11.5 4.2 8.3 1.3 11.1 4.9 7.1 1.4 10.3 3.8 288 8 297 165 -8.6 0 -8.3 -8.7 12/03/2005 18:10:00 8.1 1.3 11.1 4.9 8.2 1.3 11.1 4.9 7 1.4 10.7 3.4 292 9 289 165 -8.5 0.1 -8.3 -8.9 12/03/2005 18:20:00 5.7 1.1 8.8 3 5.7 1.1 8.4 2.6 5.4 1.1 8.8 3 291 10 277 165 -8.3 0 -8.1 -8.5 12/03/2005 18:30:00 6 1.3 8.4 2.3 6.1 1.3 8.8 2.3 5.6 1.5 8.4 1.1 285 9 282 165 -8.3 0 -8.1 -8.5 12/03/2005 18:40:00 6.5 1 8.4 3.8 6.5 1 8.4 4.2 5.7 1 8.4 3 292 9 294 165 -8.3 0 -8.1 -8.5 12/03/2005 18:50:00 6.6 1.2 9.5 3 6.7 1.2 9.5 3.8 6.2 1.5 9.5 1.9 288 9 284 165 -8.2 0 -7.9 -8.3 12/03/2005 19:00:00 8 1.1 10.3 4.9 8 1.1 10.3 4.9 6.1 1 8.8 3.8 297 7 292 165 -8.1 0 -8.1 -8.3 12/03/2005 19:10:00 7.7 1.1 9.9 4.9 7.7 1.1 9.5 4.9 5.7 1 9.1 3.4 297 5 289 165 -8.2 0 -8.1 -8.5 12/03/2005 19:20:00 7.5 1 9.5 4.6 7.5 1 9.1 4.6 5.8 0.8 8 3.8 303 6 305 165 -8.1 0 -8.1 -8.3 12/03/2005 19:30:00 5.4 1.3 8.4 2.6 5.4 1.3 8.4 2.6 4.5 1 6.8 1.9 307 8 305 165 -8.1 0 -8.1 -8.1 12/03/2005 19:40:00 3.7 0.6 5.3 2.3 3.7 0.6 5.3 2.3 3.2 0.7 4.9 1.9 294 10 287 165 -8.2 0 -8.1 -8.5 12/03/2005 19:50:00 3.4 0.9 5.7 1.5 3.4 0.9 5.7 1.5 2.9 0.8 5.7 1.5 288 12 291 165 -8.2 0 -8.1 -8.5 12/03/2005 20:00:00 3.8 0.9 5.7 1.5 3.9 0.9 6.1 1.9 3.4 0.8 5.7 1.9 285 15 295 165 -8.1 0.1 -8.1 -8.5 12/03/2005 20:10:00 3.5 0.8 4.9 1.5 3.5 0.8 4.9 1.5 2.9 0.6 4.6 1.5 296 13 307 165 -8.3 0 -8.1 -8.5 12/03/2005 20:20:00 4.1 0.6 5.7 2.6 4.1 0.6 6.1 2.6 3.4 0.5 5.3 2.3 305 8 298 165 -8.5 0 -8.3 -8.7 12/03/2005 20:30:00 3.7 0.4 5.3 2.6 3.7 0.4 5.3 2.6 3 0.6 4.9 1.5 302 10 282 165 -8.7 0 -8.5 -8.9 12/03/2005 20:40:00 2.6 1.2 4.6 0.4 2.6 1.2 4.6 0.4 2.3 1 4.2 0.4 326 32 302 165 -8.4 0 -8.3 -8.7 12/03/2005 20:50:00 1.8 0.5 3 0.4 1.7 0.5 3 0.4 1.7 0.6 3.4 0.4 330 41 298 165 -8.3 0.1 -8.1 -8.5 12/03/2005 21:00:00 2.6 0.5 3.8 1.5 2.1 0.6 3.8 0.7 2.4 0.7 3.4 0.4 339 24 350 165 -8.3 0 -8.1 -8.5 12/03/2005 21:10:00 2.3 0.6 4.2 0.4 2.1 0.7 3.8 0.4 1.9 0.5 3.4 0.4 324 27 300 165 -8.1 0 -8.1 -8.3 12/03/2005 21:20:00 2.9 0.7 5.3 1.1 2.9 0.7 5.3 1.1 2.5 0.6 3.8 1.5 305 16 300 165 -8 0.1 -7.9 -8.3 12/03/2005 21:30:00 3.8 0.8 6.1 1.9 3.8 0.8 5.7 1.9 3.4 1 5.7 1.1 304 15 275 165 -7.9 0 -7.6 -8.1 12/03/2005 21:40:00 5.9 1.4 8.8 2.6 5.9 1.4 8.8 2.3 4.9 1 8 2.6 298 10 297 165 -7.9 0 -7.6 -8.1 12/03/2005 21:50:00 7.6 1 10.3 4.6 7.5 1.1 9.9 4.9 6.1 0.8 8.8 3.8 308 8 299 165 -7.8 0.1 -7.6 -8.1 12/03/2005 22:00:00 5.6 0.6 7.2 3.8 5.6 0.7 7.2 3.8 5.3 0.7 7.2 3.4 320 10 321 165 -7.8 0 -7.6 -8.1 12/03/2005 22:10:00 6.7 0.6 8.8 5.3 6.7 0.6 8.8 4.9 5.9 1 9.1 3.8 312 10 314 165 -7.8 0 -7.6 -8.1 12/03/2005 22:20:00 5.9 1.1 8.4 2.6 5.9 1.1 8 2.6 4.7 1 7.2 1.9 306 10 306 165 -7.8 0.1 -7.4 -8.1 12/03/2005 22:30:00 2.4 0.8 4.6 0.4 2.2 0.8 4.6 0.4 2.1 1 4.2 0.4 315 45 341 165 -8.2 0 -8.1 -8.5 12/03/2005 22:40:00 1.4 1 4.2 0.4 1.3 1 4.2 0.4 1.2 0.7 3 0.4 327 76 304 165 -8.3 0 -8.1 -8.5 12/03/2005 22:50:00 2.5 0.6 3.8 0.7 2.4 0.6 3.8 0.7 2.1 0.5 3 0.7 306 16 323 165 -8 0 -7.9 -8.1 12/03/2005 23:00:00 0.8 0.5 2.6 0.4 0.9 0.5 2.3 0.4 1 0.5 1.9 0.4 305 72 302 165 -7.9 0 -7.6 -8.1 12/03/2005 23:10:00 1.5 0.7 2.6 0.4 1.5 0.7 2.6 0.4 1.4 0.6 2.6 0.4 161 72 122 165 -8 0 -7.6 -8.1 12/03/2005 23:20:00 1.1 0.4 1.9 0.4 1 0.4 1.9 0.4 0.9 0.4 2.3 0.4 303 28 257 165 -7.6 0.1 -7.2 -7.9 12/03/2005 23:30:00 1.4 0.8 3.4 0.4 1.4 0.8 3.4 0.4 1.2 0.6 2.6 0.4 316 26 311 165 -7.8 0 -7.4 -7.9 12/03/2005 23:40:00 0.8 0.4 1.9 0.4 0.7 0.4 1.9 0.4 0.9 0.4 1.9 0.4 7 22 1 165 -7.7 0 -7.4 -7.9 12/03/2005 23:50:00 0.6 0.5 1.9 0.4 0.7 0.5 2.3 0.4 0.7 0.5 1.9 0.4 310 43 326 165 -7.9 0.1 -7.6 -8.1 12/04/2005 00:00:00 0.5 0.3 1.9 0.4 0.5 0.3 1.9 0.4 0.5 0.2 1.1 0.4 349 35 315 165 -8 0.1 -7.6 -8.1 12/04/2005 00:10:00 1.5 0.8 2.6 0.4 1.6 0.7 2.6 0.4 1.7 0.7 2.6 0.4 116 17 128 165 -7.9 0 -7.6 -8.3 12/04/2005 00:20:00 0.7 0.6 2.3 0.4 0.9 0.6 2.3 0.4 1.1 0.5 2.3 0.4 123 36 128 165 -7.4 0.2 -6.8 -7.6 12/04/2005 00:30:00 0.4 0.1 1.1 0.4 0.5 0.3 1.1 0.4 0.4 0.1 1.1 0.4 89 0 89 165 -7.5 0.2 -6.8 -7.9 12/04/2005 00:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0.1 1.1 0.4 89 0 165 165 -7.8 0 -7.6 -8.1 12/04/2005 00:50:00 0.7 0.3 1.5 0.4 0.8 0.4 1.5 0.4 0.7 0.3 1.5 0.4 106 22 89 165 -8.1 0 -7.9 -8.3 12/04/2005 01:00:00 0.7 0.3 1.5 0.4 0.8 0.4 1.5 0.4 0.8 0.4 1.9 0.4 133 3 138 165 -7.9 0 -7.6 -8.1 12/04/2005 01:10:00 0.8 0.5 1.9 0.4 0.8 0.4 1.9 0.4 0.8 0.4 1.5 0.4 335 90 305 165 -8 0.1 -7.6 -8.3 12/04/2005 01:20:00 0.4 0 0.7 0.4 0.4 0.1 1.1 0.4 0.4 0.2 1.1 0.4 263 0 262 165 -7.6 0 -7.4 -7.6 12/04/2005 01:30:00 0.5 0.2 1.1 0.4 0.6 0.3 1.1 0.4 0.7 0.4 1.5 0.4 317 49 2 165 -7.8 0 -7.6 -8.1 12/04/2005 01:40:00 1.6 0.4 2.3 0.7 1.4 0.4 2.3 0.7 1.8 0.3 2.3 1.1 9 7 16 165 -7.9 0 -7.6 -8.1 12/04/2005 01:50:00 2.1 0.2 2.6 1.9 1.9 0.2 2.3 1.5 2.1 0.2 2.6 1.5 18 2 19 165 -7.7 0 -7.6 -7.9 12/04/2005 02:00:00 1.9 0.3 2.6 1.5 1.5 0.3 2.3 0.7 1.9 0.4 2.6 1.1 12 3 13 165 -7.6 0 -7.6 -7.6 12/04/2005 02:10:00 1.7 0.2 2.3 1.5 1.6 0.2 1.9 1.1 1.7 0.2 2.3 1.1 18 1 18 165 -7.5 0 -7.2 -7.6 12/04/2005 02:20:00 1.1 0.3 1.9 0.4 1.1 0.3 1.9 0.4 1.2 0.3 1.9 0.7 23 6 18 165 -7.5 0 -7.2 -7.4 12/04/2005 02:30:00 0.9 0.4 1.5 0.4 0.9 0.2 1.5 0.4 1 0.2 1.5 0.7 30 0 31 165 -7.6 0 -7.4 -7.6 12/04/2005 02:40:00 0.5 0.3 1.1 0.4 0.7 0.3 1.1 0.4 0.6 0.3 1.1 0.4 30 0 31 165 -7.5 0.1 -7.2 -7.6 12/04/2005 02:50:00 0.7 0.4 1.5 0.4 0.9 0.4 1.9 0.4 0.8 0.4 1.9 0.4 55 20 31 165 -7.2 0 -7 -7.4 12/04/2005 03:00:00 1.1 0.2 1.5 0.4 1 0.2 1.5 0.4 1.1 0.2 1.5 0.7 37 11 57 165 -7.4 0.1 -7 -7.6 12/04/2005 03:10:00 0.6 0.3 1.5 0.4 0.7 0.2 1.1 0.4 0.8 0.2 1.1 0.4 30 0 29 165 -7.6 0 -7.4 -7.6 12/04/2005 03:20:00 0.8 0.4 1.5 0.4 0.9 0.4 1.5 0.4 0.9 0.2 1.1 0.4 30 0 30 165 -7.5 0 -7.4 -7.6 12/04/2005 03:30:00 0.4 0 0.7 0.4 0.5 0.2 1.1 0.4 0.4 0.1 1.1 0.4 44 18 68 165 -7.6 0.1 -7.2 -7.9 12/04/2005 03:40:00 0.4 0 0.4 0.4 0.4 0.1 0.7 0.4 0.4 0.1 1.1 0.4 68 0 165 165 -7.1 0 -6.8 -7.2 12/04/2005 03:50:00 0.7 0.4 1.5 0.4 0.8 0.4 1.5 0.4 0.8 0.4 1.9 0.4 61 12 57 165 -6.9 0.1 -6.6 -7.2 12/04/2005 04:00:00 1.4 0.2 1.9 1.1 1.1 0.3 1.9 0.4 1.3 0.2 1.9 1.1 22 6 18 165 -7 0 -6.6 -7.2 12/04/2005 04:10:00 2 0.3 3 1.1 2 0.4 3 1.1 2.1 0.4 2.6 1.5 52 11 63 165 -6.8 0.1 -6.6 -7.2 12/04/2005 04:20:00 2.3 0.2 3 1.9 2.4 0.3 3 1.9 2.4 0.2 3 1.9 64 6 66 165 -6.5 0 -6.4 -6.8 12/04/2005 04:30:00 1.8 0.3 2.6 1.1 1.8 0.3 2.6 1.1 1.9 0.2 2.3 1.1 68 3 70 165 -6.4 0.1 -6.1 -6.6 12/04/2005 04:40:00 1.7 0.4 2.3 0.4 1.8 0.4 2.3 0.7 1.8 0.3 2.6 1.1 72 5 61 165 -6.3 0 -6.1 -6.6 12/04/2005 04:50:00 1.6 0.4 2.3 0.7 1.7 0.4 2.6 1.1 1.7 0.3 2.6 1.1 84 6 78 165 -6.3 0 -6.1 -6.6 12/04/2005 05:00:00 2.1 0.4 3 1.5 2.2 0.4 3 1.5 2.2 0.4 3 1.5 96 16 117 165 -6.5 0 -6.1 -6.6 12/04/2005 05:10:00 2.2 0.3 2.6 1.5 2.2 0.3 3 1.9 2.3 0.3 3 1.9 102 5 118 165 -6.6 0 -6.6 -6.8 12/04/2005 05:20:00 2 0.2 2.6 1.5 2.1 0.2 2.6 1.5 2.1 0.2 2.6 1.5 101 0 101 165 -6.6 0 -6.6 -6.8 12/04/2005 05:30:00 2.1 0.3 2.6 1.5 2.1 0.3 2.6 1.5 2 0.3 2.6 1.5 114 10 111 165 -6.7 0 -6.6 -6.8 12/04/2005 05:40:00 2 0.3 2.6 1.1 2 0.3 2.6 1.1 1.8 0.4 2.6 1.1 133 9 139 165 -6.8 0 -6.6 -7 12/04/2005 05:50:00 2.7 0.4 3.4 1.9 2.7 0.4 3.4 1.9 2.7 0.4 3.8 1.9 145 8 157 165 -6.5 0.1 -6.4 -6.8 12/04/2005 06:00:00 2.1 0.3 3 1.5 2.2 0.3 3 1.5 2 0.4 2.6 1.1 125 6 131 165 -6.5 0 -6.1 -6.6 12/04/2005 06:10:00 2.4 0.4 3.4 1.5 2.5 0.4 3.4 1.9 2.5 0.4 3.4 1.5 122 6 127 165 -6.5 0 -6.4 -6.6 12/04/2005 06:20:00 2 0.3 2.6 1.1 2.1 0.3 2.6 1.5 2.1 0.3 2.6 1.5 116 6 113 165 -6.5 0 -6.4 -6.6 12/04/2005 06:30:00 2 0.4 3 1.5 2.1 0.3 3 1.5 2.1 0.3 3 1.5 111 5 124 165 -6.6 0.1 -6.4 -6.8 12/04/2005 06:40:00 2.5 0.2 3 1.9 2.6 0.2 3 2.3 2.5 0.2 3 1.9 124 1 124 165 -6.5 0 -6.1 -6.6 12/04/2005 06:50:00 2.3 0.2 3 1.9 2.4 0.2 2.6 1.9 2.3 0.2 2.6 1.9 143 8 148 165 -6.5 0 -6.4 -6.6 12/04/2005 07:00:00 2.1 0.4 2.6 1.5 2.1 0.4 2.6 1.5 2.1 0.3 2.6 1.1 146 1 148 165 -6.5 0 -6.4 -6.6 12/04/2005 07:10:00 1.8 0.2 2.3 1.5 1.9 0.2 2.3 1.5 1.7 0.2 2.3 1.1 140 7 146 165 -6.5 0 -6.4 -6.6 12/04/2005 07:20:00 1.5 0.2 1.9 1.1 1.5 0.2 1.9 1.1 1.4 0.2 1.9 0.7 128 0 128 165 -6.7 0 -6.6 -6.8 12/04/2005 07:30:00 2.1 0.5 3 1.1 2.1 0.5 3 1.1 2.1 0.5 3.4 1.1 141 12 158 165 -6.6 0 -6.4 -6.6 12/04/2005 07:40:00 2.6 0.3 3 1.5 2.6 0.3 3 1.9 2.4 0.3 3 1.5 144 5 151 165 -6.5 0 -6.4 -6.6 12/04/2005 07:50:00 2.5 0.3 3 1.5 2.5 0.3 3 1.5 2.5 0.3 3 1.5 144 5 135 165 -6.4 0 -6.1 -6.6 12/04/2005 08:00:00 2.7 0.3 3.4 2.3 2.8 0.3 3.4 2.3 2.8 0.3 3.4 2.3 148 3 148 165 -6.4 0 -6.1 -6.6 12/04/2005 08:10:00 2.6 0.3 3.4 1.9 2.7 0.3 3.4 1.9 2.5 0.3 3.4 1.9 147 5 147 165 -6.4 0 -6.4 -6.6 12/04/2005 08:20:00 2.8 0.4 3.4 1.5 2.8 0.4 3.4 1.5 2.6 0.4 3.4 1.5 153 6 160 165 -6.5 0 -6.4 -6.6 12/04/2005 08:30:00 3.6 0.3 4.2 2.3 3.5 0.3 4.2 2.6 3.2 0.3 3.8 2.3 156 3 156 165 -6.6 0 -6.4 -6.6 12/04/2005 08:40:00 3.8 0.4 4.6 3.4 3.7 0.3 4.6 3.4 3.5 0.3 4.6 2.6 155 2 154 165 -6.5 0 -6.4 -6.8 12/04/2005 08:50:00 4.2 0.4 4.9 3.4 4.1 0.4 4.6 3 4 0.4 4.6 3 155 3 161 165 -6.6 0 -6.6 -6.6 12/04/2005 09:00:00 4.2 0.3 4.9 2.6 4.1 0.3 4.6 3 3.8 0.3 4.6 3.4 155 3 154 165 -6.6 0 -6.4 -6.8 12/04/2005 09:10:00 4.5 0.4 5.3 3.4 4.3 0.4 4.9 3 4.2 0.4 4.9 3.4 157 3 157 165 -6.4 0.1 -6.1 -6.6 12/04/2005 09:20:00 4.6 0.4 5.3 3 4.5 0.3 4.9 3 4.4 0.4 4.9 3.4 163 4 164 165 -6.4 0 -6.1 -6.6 12/04/2005 09:30:00 4.3 0.5 5.3 3 4.1 0.4 5.3 2.6 4.1 0.4 4.9 3 164 9 178 165 -6.2 0 -6.1 -6.4 12/04/2005 09:40:00 4.9 0.6 6.1 3.4 4.7 0.5 5.7 3 4.6 0.5 5.7 3 173 5 178 165 -6.2 0 -5.9 -6.4 12/04/2005 09:50:00 4.8 0.6 5.7 3.4 4.6 0.5 5.7 3.4 4.4 0.5 5.7 3.4 178 4 180 165 -6.1 0 -5.7 -6.1 12/04/2005 10:00:00 4.6 0.3 5.3 3.4 4.6 0.3 5.3 3.4 4.2 0.5 5.3 3 184 3 183 165 -6.1 0 -5.9 -6.1 12/04/2005 10:10:00 5 0.3 5.7 4.2 4.9 0.3 5.7 4.2 5 0.3 5.7 4.2 173 3 169 165 -5.6 0.2 -5.3 -5.9 12/04/2005 10:20:00 5.6 0.2 6.1 4.9 5.4 0.2 6.1 4.9 5.6 0.3 6.5 4.9 177 2 180 165 -5.3 0 -5.3 -5.5 12/04/2005 10:30:00 5.4 0.4 6.5 4.6 5.2 0.3 5.7 4.2 5.4 0.4 6.1 4.6 171 4 171 165 -5.3 0 -5 -5.3 12/04/2005 10:40:00 5.2 0.3 6.1 4.6 5.1 0.3 6.1 4.6 5.1 0.3 5.7 4.2 168 8 164 165 -4.9 0.1 -4.6 -5.3 12/04/2005 10:50:00 4.3 0.4 5.3 3.4 4.2 0.4 4.9 3.4 4.2 0.4 4.9 3.4 166 8 164 165 -4.7 0 -4.6 -4.8 12/04/2005 11:00:00 4.1 0.2 4.6 3.8 4 0.2 4.6 3.4 4.2 0.2 4.6 3.8 166 9 164 165 -4.7 0 -4.4 -4.6 12/04/2005 11:10:00 4.2 0.2 4.9 3.8 4.1 0.2 4.9 3.8 4.3 0.2 4.9 3.8 166 9 164 165 -4.5 0 -4.4 -4.6 12/04/2005 11:20:00 4.6 0.2 4.9 4.2 4.4 0.2 4.9 3.8 4.7 0.2 4.9 4.2 164 15 169 165 -4.4 0 -4.2 -4.6 12/04/2005 11:30:00 4.3 0.3 5.3 3.8 4.2 0.3 4.9 3.8 4.4 0.3 4.9 3.8 172 3 178 165 -4.3 0 -4.2 -4.4 12/04/2005 11:40:00 4.7 0.2 5.3 4.2 4.6 0.2 4.9 4.2 4.6 0.3 5.3 4.2 178 2 182 165 -4.2 0 -4.2 -4.4 12/04/2005 11:50:00 4.6 0.3 5.3 3.8 4.5 0.3 5.3 3.4 4.5 0.4 5.3 3.8 176 3 178 165 -4.1 0 -3.9 -4.4 12/04/2005 12:00:00 4 0.3 4.9 3.4 3.9 0.2 4.6 3.4 4 0.3 4.6 3.4 178 3 178 165 -4 0 -3.9 -4.2 12/04/2005 12:10:00 4.3 0.2 4.9 3.8 4.2 0.2 4.6 3.8 4.4 0.3 4.9 3.4 181 3 177 165 -3.9 0 -3.7 -3.9 12/04/2005 12:20:00 4.5 0.3 4.9 3.8 4.4 0.2 4.9 3.8 4.5 0.3 4.9 3.8 179 2 176 165 -3.8 0 -3.7 -3.9 12/04/2005 12:30:00 4.5 0.3 4.9 3.8 4.4 0.2 4.9 3.8 4.4 0.3 5.3 3.4 178 3 179 165 -3.7 0 -3.5 -3.9 12/04/2005 12:40:00 4.6 0.4 6.1 3.8 4.4 0.3 5.7 3.8 4.4 0.3 5.3 3.4 173 4 171 165 -3.6 0 -3.5 -3.5 12/04/2005 12:50:00 4.2 0.4 5.3 3 4 0.4 4.9 3 4 0.4 5.3 3 174 6 181 165 -3.5 0 -3.3 -3.5 12/04/2005 13:00:00 5.1 0.4 6.1 3.8 4.9 0.4 5.7 3.8 4.9 0.5 6.1 3.4 168 6 169 165 -3.4 0 -3.3 -3.5 12/04/2005 13:10:00 4.7 0.4 6.1 3.8 4.5 0.4 5.7 3.8 4.7 0.4 6.1 3.4 168 6 168 165 -3.3 0 -3 -3.5 12/04/2005 13:20:00 4.1 0.5 6.1 2.6 3.9 0.5 5.7 2.6 3.9 0.4 4.9 3 166 9 162 165 -3.2 0 -3 -3.3 12/04/2005 13:30:00 2.7 0.5 3.8 1.5 2.7 0.5 3.8 1.5 2.7 0.4 3.8 1.9 162 4 170 165 -3.2 0 -3 -3.3 12/04/2005 13:40:00 1.8 0.4 2.6 0.7 1.9 0.4 2.6 1.1 1.8 0.4 2.6 1.1 158 12 165 165 -3 0 -3 -3.3 12/04/2005 13:50:00 2.5 1.3 5.7 0.7 2.5 1.3 5.7 0.7 2.4 1.3 6.1 0.7 148 12 128 165 -3 0 -2.8 -3 12/04/2005 14:00:00 4.4 0.9 6.5 2.3 4.4 0.9 6.1 2.3 4.3 0.8 6.5 2.6 137 9 143 165 -2.6 0.1 -2.6 -2.8 12/04/2005 14:10:00 4.5 0.7 6.1 2.6 4.5 0.8 6.1 2.3 4.4 0.7 6.1 3 134 9 143 165 -2.6 0 -2.6 -2.8 12/04/2005 14:20:00 4.4 0.7 5.7 2.3 4.4 0.7 5.7 2.6 4.2 0.6 5.3 2.6 134 7 135 165 -2.6 0 -2.6 -2.8 12/04/2005 14:30:00 4.3 0.5 5.7 2.6 4.3 0.5 6.1 2.6 4.2 0.5 5.7 2.6 134 8 133 165 -2.6 0 -2.6 -2.8 12/04/2005 14:40:00 4.6 0.6 6.5 3.4 4.6 0.6 6.5 3.4 4.4 0.6 6.1 3.4 136 9 145 165 -2.6 0 -2.6 -2.8 12/04/2005 14:50:00 5.6 0.9 8 3.8 5.6 0.9 8 3 5.3 1 7.6 2.6 134 6 131 165 -2.5 0 -2.6 -2.8 12/04/2005 15:00:00 5.1 0.6 7.2 4.2 5.2 0.6 7.2 3.8 4.9 0.5 6.8 3.8 133 7 138 165 -2.5 0 -2.4 -2.6 12/04/2005 15:10:00 6.1 0.8 7.6 4.2 6.1 0.7 7.6 4.2 5.8 0.7 7.6 3.8 122 5 113 165 -2.3 0 -2.1 -2.6 12/04/2005 15:20:00 7.5 0.6 8.8 5.7 7.7 0.6 8.8 6.1 7.3 0.7 9.1 4.9 118 4 119 165 -2.1 0 -1.9 -2.1 12/04/2005 15:30:00 7.7 0.5 8.8 6.5 7.8 0.5 9.1 6.5 7.4 0.6 8.8 5.7 121 4 118 165 -2 0 -1.9 -2.1 12/04/2005 15:40:00 7.5 0.4 9.1 6.5 7.7 0.4 9.5 6.8 7.3 0.4 8.4 6.1 122 3 124 165 -2 0 -1.9 -2.1 12/04/2005 15:50:00 8.3 0.7 9.9 6.8 8.5 0.7 10.3 6.8 8.1 0.7 9.9 6.1 123 3 122 165 -1.9 0 -1.7 -1.9 12/04/2005 16:00:00 8.2 0.5 9.5 6.5 8.4 0.5 9.9 7.2 7.9 0.6 9.1 6.5 123 4 122 165 -1.7 0 -1.7 -1.9 12/04/2005 16:10:00 8.3 0.5 9.5 7.2 8.5 0.5 9.9 7.2 8.2 0.5 9.5 6.8 121 3 119 165 -1.7 0 -1.4 -1.9 12/04/2005 16:20:00 8.7 0.6 10.7 7.2 8.9 0.6 10.7 6.8 8.5 0.6 10.3 6.5 122 5 126 165 -1.6 0 -1.4 -1.7 12/04/2005 16:30:00 8.5 0.8 11.1 6.8 8.7 0.8 11.5 6.8 8.4 0.8 11.1 6.5 125 5 128 165 -1.4 0 -1.4 -1.4 12/04/2005 16:40:00 8.3 0.8 10.7 6.5 8.5 0.8 11.1 6.5 8.1 0.8 10.7 6.1 125 5 130 165 -1.4 0 -1.2 -1.4 12/04/2005 16:50:00 7.9 0.8 9.9 6.1 8.1 0.8 10.3 6.1 7.8 0.9 9.9 5.7 126 6 126 165 -1.3 0 -1.2 -1.4 12/04/2005 17:00:00 8 0.7 10.7 6.5 8.2 0.7 11.1 6.8 7.9 0.8 10.7 5.7 125 5 126 165 -1.2 0 -1.2 -1.2 12/04/2005 17:10:00 7 0.6 8.8 5.7 7.2 0.6 8.8 5.7 6.9 0.6 8.4 5.3 124 5 121 165 -1.3 0 -1.2 -1.4 12/04/2005 17:20:00 6.5 0.4 8 5.3 6.6 0.4 8 5.3 6.3 0.5 7.2 5.3 120 5 121 165 -1.2 0 -1.2 -1.4 12/04/2005 17:30:00 6.9 0.4 8.4 5.7 7.1 0.4 8.4 6.1 6.7 0.5 8 4.9 121 5 123 165 -1.2 0 -1 -1.2 12/04/2005 17:40:00 6.5 0.5 8 4.9 6.7 0.5 8 4.9 6.5 0.5 7.6 4.2 122 5 122 165 -1.1 0 -1 -1.2 12/04/2005 17:50:00 6.9 0.5 8 4.9 7.1 0.5 8.4 4.6 6.7 0.5 8 4.9 117 5 114 165 -1 0 -1 -1.2 12/04/2005 18:00:00 7 0.4 8 5.7 7.2 0.4 8.4 5.7 6.8 0.6 8 5.3 115 4 114 165 -1 0 -0.8 -1.2 12/04/2005 18:10:00 7.6 0.6 9.1 5.7 7.7 0.5 9.1 5.7 7.3 0.7 9.1 4.9 118 5 107 165 -0.9 0 -0.8 -1 12/04/2005 18:20:00 7.3 0.6 8.4 5.7 7.4 0.6 8.8 5.3 7 0.7 8.8 4.6 118 5 114 165 -0.8 0 -0.8 -1 12/04/2005 18:30:00 7.6 0.6 9.1 5.7 7.8 0.6 9.5 4.9 7.3 0.8 9.1 4.9 119 4 117 165 -0.6 0 -0.5 -1 12/04/2005 18:40:00 7.7 0.6 9.1 6.1 7.9 0.6 9.5 6.1 7.5 0.7 9.5 5.3 118 5 114 165 -0.5 0 -0.5 -0.8 12/04/2005 18:50:00 7.5 0.9 9.9 5.7 7.6 0.9 9.9 5.7 7.4 0.9 9.9 5.3 119 4 110 165 -0.5 0 -0.3 -0.5 12/04/2005 19:00:00 7.8 0.6 9.5 6.1 8 0.6 9.5 6.1 7.6 0.7 9.5 4.9 119 4 117 165 -0.3 0 -0.3 -0.5 12/04/2005 19:10:00 7.8 0.4 8.8 6.5 8.1 0.4 9.1 6.8 7.8 0.5 8.8 5.7 123 3 118 165 -0.3 0 -0.1 -0.5 12/04/2005 19:20:00 7 0.6 8.8 5.3 7.3 0.6 9.1 5.7 7 0.6 8.8 5.3 124 3 119 165 -0.2 0 -0.1 -0.3 12/04/2005 19:30:00 8.9 0.8 10.7 6.5 9.1 0.9 11.1 6.8 8.8 1.1 11.1 5.3 123 6 123 165 -0.1 0 -0.1 -0.1 12/04/2005 19:40:00 8.1 0.7 10.3 6.5 8.3 0.8 10.7 6.5 8.3 0.8 10.3 6.1 127 4 122 165 -0.1 0 0.2 -0.1 12/04/2005 19:50:00 9.3 0.7 11.1 7.2 9.5 0.7 11.8 7.6 9.4 0.8 11.8 6.8 123 5 121 165 0 0 0.2 -0.1 12/04/2005 20:00:00 8.9 0.9 11.5 7.2 9.1 0.8 11.8 7.2 9 0.8 11.5 7.2 126 5 123 165 0 0 0.2 -0.1 12/04/2005 20:10:00 8.7 0.7 11.1 6.8 9 0.7 11.5 6.8 8.8 0.8 11.1 6.5 125 5 129 165 0.1 0 0.2 -0.1 12/04/2005 20:20:00 8.6 0.7 10.7 6.1 8.8 0.7 10.7 6.5 8.7 0.8 10.7 6.5 128 5 134 165 0.2 0 0.2 0.2 12/04/2005 20:30:00 8.5 0.7 10.3 6.1 8.7 0.7 10.3 5.3 8.5 0.8 9.9 4.9 129 6 135 165 0.2 0 0.2 0.2 12/04/2005 20:40:00 9 0.7 11.5 6.8 9.2 0.7 11.8 7.2 9.1 0.9 11.8 6.1 124 5 127 165 0.2 0 0.2 0.2 12/04/2005 20:50:00 7.9 0.9 11.5 6.1 8.1 1 11.5 5.7 8 1 11.8 5.3 125 6 133 165 0.2 0 0.4 0.2 12/04/2005 21:00:00 8.5 0.8 10.7 6.5 8.7 0.8 11.1 5.7 8.7 0.8 10.7 6.1 121 5 121 165 0.2 0 0.4 0.2 12/04/2005 21:10:00 8.6 0.7 10.7 7.2 8.7 0.6 11.1 7.2 8.7 0.8 11.5 6.1 123 4 126 165 0.4 0 0.7 0.2 12/04/2005 21:20:00 8.2 0.6 9.9 6.8 8.4 0.6 9.9 6.8 8.4 0.6 9.9 6.5 129 5 129 165 0.5 0 0.7 0.4 12/04/2005 21:30:00 8.8 0.9 11.5 6.8 8.9 0.9 11.5 6.8 8.8 0.9 10.7 6.8 130 6 125 165 0.5 0 0.7 0.4 12/04/2005 21:40:00 8.7 0.7 10.7 6.8 8.8 0.7 10.3 6.5 8.6 0.8 10.7 6.1 131 6 140 165 0.5 0 0.7 0.4 12/04/2005 21:50:00 8 0.7 9.9 6.5 8 0.7 10.3 5.7 7.9 0.7 9.5 5.3 126 6 130 165 0.5 0 0.7 0.4 12/04/2005 22:00:00 8.7 0.7 10.7 6.8 8.9 0.7 10.7 6.8 8.6 0.7 10.3 6.5 120 4 126 165 0.5 0 0.7 0.7 12/04/2005 22:10:00 8.4 0.8 10.7 6.5 8.6 0.9 11.1 6.5 8.4 1.1 10.7 5.3 118 5 116 165 0.6 0 0.7 0.7 12/04/2005 22:20:00 7.3 0.5 8.4 5.7 7.6 0.5 8.8 6.1 7.2 0.6 8.4 5.7 112 4 119 165 0.7 0 0.9 0.7 12/04/2005 22:30:00 7.6 0.6 9.1 6.5 8 0.6 9.5 6.5 7.5 0.8 9.1 5.3 110 4 116 165 0.7 0 0.9 0.7 12/04/2005 22:40:00 8.2 0.5 9.5 6.8 8.5 0.5 9.9 6.8 8.1 0.7 9.5 6.1 113 4 113 165 0.8 0 0.9 0.7 12/04/2005 22:50:00 8.5 0.6 9.9 6.8 9 0.7 10.7 6.8 8.3 0.9 9.9 5.3 104 5 110 165 0.7 0 0.9 0.7 12/04/2005 23:00:00 7.7 1 9.5 5.3 8.1 1.1 10.3 5.3 7.6 1 10.3 4.9 99 0 99 165 0.7 0 0.9 0.7 12/04/2005 23:10:00 7.5 0.7 9.1 5.7 7.9 0.8 9.9 5.7 7.3 0.8 9.5 4.2 99 0 99 165 0.8 0 0.9 0.7 12/04/2005 23:20:00 8 0.8 9.5 5.7 8.3 0.9 9.9 5.3 7.8 1 9.5 4.9 99 0 99 165 0.8 0 0.9 0.9 12/04/2005 23:30:00 8.1 0.9 9.9 6.1 8.4 1 10.3 5.7 7.9 0.9 10.3 5.7 99 0 99 165 0.8 0 0.9 0.9 12/04/2005 23:40:00 7.4 0.8 9.1 4.9 7.7 0.9 9.5 5.3 7.3 0.9 9.1 4.9 99 0 99 165 0.9 0 1.1 0.9 12/04/2005 23:50:00 8.1 0.8 9.9 5.7 8.4 1 10.7 5.7 7.8 0.9 10.3 5.7 99 0 99 165 1 0 1.1 0.9 12/05/2005 00:00:00 7.7 0.8 9.5 5.3 8 1 9.9 5.3 7.3 1 9.5 5.3 99 0 99 165 1.1 0 1.4 0.9 12/05/2005 00:10:00 7.4 0.7 9.1 5.3 7.6 0.9 9.5 5.3 7.2 0.9 9.1 4.9 99 0 99 165 1.2 0 1.4 1.1 12/05/2005 00:20:00 7.6 0.8 9.5 5.3 7.7 0.8 9.5 5.3 7.4 0.8 9.5 5.3 99 0 99 165 1.2 0 1.4 0.9 12/05/2005 00:30:00 7.5 0.9 9.5 4.9 7.7 1 9.9 5.3 7.3 1.1 9.9 4.2 99 0 99 165 1.4 0 1.4 1.4 12/05/2005 00:40:00 7.6 0.7 9.5 5.7 7.8 0.8 9.1 5.7 7.3 0.9 9.1 4.9 99 0 99 165 1.4 0 1.6 1.4 12/05/2005 00:50:00 7.5 0.7 9.1 5.3 7.6 0.7 9.1 5.3 7.2 0.8 9.5 4.9 99 0 99 165 1.4 0 1.6 1.4 12/05/2005 01:00:00 7.4 0.7 8.8 5.3 7.4 0.8 9.1 4.9 7.3 0.8 9.1 4.9 99 0 99 165 1.4 0 1.6 1.4 12/05/2005 01:10:00 7.3 0.7 9.1 5.3 7.4 0.8 9.9 5.3 7.4 0.8 9.1 4.6 99 0 99 165 1.6 0 1.6 1.6 12/05/2005 01:20:00 6.7 1 9.5 4.9 6.8 1.1 9.9 4.9 6.7 1.1 10.3 4.2 99 0 99 165 1.7 0 1.8 1.6 12/05/2005 01:30:00 7.5 0.8 9.1 4.9 7.7 0.9 9.9 4.9 7.5 0.9 9.5 5.3 99 0 99 165 1.7 0 1.8 1.6 12/05/2005 01:40:00 6.9 0.8 8.4 4.9 6.9 0.8 8.8 4.6 6.9 0.9 8.8 4.6 99 0 99 165 1.7 0 1.8 1.6 12/05/2005 01:50:00 6.6 1 8.8 3.8 6.5 1 8.8 3.8 6.5 1 8.8 4.2 99 0 99 165 1.7 0 1.8 1.6 12/05/2005 02:00:00 7.7 0.8 9.5 5.3 7.6 0.8 9.9 5.3 7.5 0.8 9.9 5.3 99 0 99 165 1.8 0 1.8 1.6 12/05/2005 02:10:00 8.4 0.9 10.7 5.7 8.8 1 11.1 5.7 8.5 1 11.1 4.9 99 0 99 165 1.8 0 1.8 1.6 12/05/2005 02:20:00 8.1 1.2 10.7 4.9 8.4 1.2 11.1 5.3 7.9 1.2 11.1 5.3 99 0 99 165 1.8 0 1.8 1.6 12/05/2005 02:30:00 7.7 1.1 10.3 4.9 7.7 1.1 10.7 4.9 7.5 1.1 10.7 5.3 98 0 98 165 1.8 0 1.8 1.6 12/05/2005 02:40:00 8 1 9.9 5.3 8 1.1 10.3 4.9 7.7 1.1 10.3 4.9 96 7 98 165 1.9 0 1.8 1.8 12/05/2005 02:50:00 8.2 1.2 11.1 5.7 8.2 1.3 11.1 5.3 8.4 1.3 11.5 5.7 78 9 85 165 2 0 2.3 1.8 12/05/2005 03:00:00 8.3 1.1 11.8 6.1 8.5 1.2 12.2 5.7 8.5 1.2 12.2 6.1 78 8 78 165 2.1 0 2.3 2.1 12/05/2005 03:10:00 9.1 1.1 12.2 6.1 9.3 1.1 11.8 6.1 9.2 1.2 12.6 6.1 82 7 82 165 2.2 0 2.3 1.8 12/05/2005 03:20:00 8.4 1.1 10.7 5.3 8.6 1.2 11.1 5.7 8.1 1.1 10.3 5.3 74 9 74 165 2.3 0 2.6 2.3 12/05/2005 03:30:00 7.9 1.2 11.1 5.3 8.1 1.3 11.1 5.7 7.9 1.3 10.3 5.3 72 8 70 165 2.3 0 2.3 2.1 12/05/2005 03:40:00 8.6 1.7 12.6 4.9 8.8 1.7 13 4.9 8.6 1.5 11.8 4.9 75 9 76 165 2.3 0 2.6 1.8 12/05/2005 03:50:00 8.2 1.3 12.6 4.9 8.4 1.4 12.6 4.9 8 1.3 11.8 4.2 72 9 88 165 2.2 0.2 2.6 1.8 12/05/2005 04:00:00 9.7 1.6 13.3 5.7 9.8 1.7 13.3 5.7 9.4 1.7 13.7 5.7 70 10 91 165 2.4 0 2.6 2.3 12/05/2005 04:10:00 8.7 1.7 14.5 4.2 8.8 1.8 14.5 4.2 8.3 1.7 13.3 4.6 69 10 65 165 2.3 0 2.6 2.3 12/05/2005 04:20:00 9.3 1.5 14.5 6.1 9.4 1.5 14.5 6.1 9 1.4 13.3 6.1 64 9 70 165 2.4 0 2.6 2.3 12/05/2005 04:30:00 7.9 1.4 11.5 5.3 7.9 1.4 11.5 4.9 7.5 1.3 11.5 4.6 59 10 84 165 2.4 0 2.6 2.3 12/05/2005 04:40:00 7.6 1.6 11.5 4.6 7.6 1.7 11.8 4.2 7.1 1.7 11.5 3.8 60 12 73 165 2.4 0 2.6 2.3 12/05/2005 04:50:00 8 1.5 11.1 4.6 8 1.6 11.5 4.2 7.7 1.5 11.1 4.2 69 11 72 165 2.5 0 2.6 2.6 12/05/2005 05:00:00 8.9 1.5 12.2 4.9 9 1.7 12.6 4.9 8.6 1.6 12.2 4.2 63 11 80 165 2.5 0 2.8 2.6 12/05/2005 05:10:00 7.9 1.5 13 4.2 8 1.6 13.3 4.2 7.6 1.4 13 4.9 59 11 74 165 2.4 0 2.6 2.3 12/05/2005 05:20:00 8.7 1.9 13.7 4.9 8.8 2 14.1 4.9 8.4 1.7 12.6 4.6 65 12 57 165 2.4 0 2.6 2.6 12/05/2005 05:30:00 8.3 1.4 11.8 4.9 8.4 1.5 12.2 4.6 8.1 1.5 12.6 4.9 55 11 70 165 2.5 0 2.6 2.6 12/05/2005 05:40:00 8.9 1.7 13 5.3 8.9 1.8 13 4.9 8.5 1.7 12.6 4.9 62 11 77 165 2.5 0 2.8 2.6 12/05/2005 05:50:00 9.2 1.6 13 5.3 9.3 1.7 13 5.3 8.9 1.5 12.2 4.9 65 11 68 165 2.6 0 2.8 2.6 12/05/2005 06:00:00 7.7 1.7 12.2 4.2 7.7 1.8 11.8 4.2 7.4 1.6 11.1 3.8 63 12 75 165 2.6 0 2.8 2.6 12/05/2005 06:10:00 9.7 1.4 13.7 6.5 9.8 1.5 13.7 6.8 9.3 1.5 13.3 5.7 69 9 73 165 2.7 0 2.8 2.6 12/05/2005 06:20:00 9.7 1.6 13.7 5.7 9.8 1.7 14.1 5.7 9.3 1.5 14.1 5.3 67 9 69 165 2.7 0 2.8 2.8 12/05/2005 06:30:00 9 1.6 12.6 5.3 9.1 1.7 12.6 5.3 8.5 1.5 13.3 4.2 65 11 78 165 2.7 0 2.8 2.8 12/05/2005 06:40:00 8.7 1.5 12.2 5.3 8.8 1.6 12.6 4.9 8.4 1.5 12.2 4.9 61 11 63 165 2.9 0 2.8 2.8 12/05/2005 06:50:00 8 1.7 12.6 4.9 8 1.8 12.6 4.6 7.7 1.5 12.2 4.9 58 12 72 165 2.9 0 2.8 2.8 12/05/2005 07:00:00 7 1.7 11.5 3.8 6.9 1.7 11.8 3.4 6.6 1.7 11.1 3 55 12 68 165 2.9 0 3 2.8 12/05/2005 07:10:00 8 2 13.3 3.8 7.9 2.1 13.3 3.8 7.5 1.9 12.6 3.8 49 14 64 165 2.9 0 3 2.8 12/05/2005 07:20:00 7.8 1.8 13.3 3.8 7.8 1.9 13.3 3.8 7.4 1.7 13 3.8 54 13 75 165 3 0 3.3 2.8 12/05/2005 07:30:00 8.4 1.5 11.8 4.6 8.4 1.6 12.2 4.9 8 1.6 12.2 3.8 56 12 39 165 3 0 3.3 2.8 12/05/2005 07:40:00 8.9 1.9 13.7 4.6 9 2.1 14.1 4.6 8.4 1.8 13 4.2 57 13 80 165 3 0 3.3 3 12/05/2005 07:50:00 7.8 1.6 11.8 4.6 7.8 1.7 12.2 4.2 7.5 1.5 11.8 4.2 51 11 58 165 3 0 3.3 3 12/05/2005 08:00:00 8.1 2 14.1 3.8 8.2 2.2 13.7 3.8 7.8 2 12.2 3 58 13 58 165 3.1 0 3.3 2.8 12/05/2005 08:10:00 7.9 1.4 12.6 5.3 7.9 1.5 13 5.3 7.5 1.3 12.2 4.6 48 12 58 165 3.2 0 3.3 3 12/05/2005 08:20:00 7.9 1.2 11.1 5.3 7.9 1.3 11.5 5.3 7.5 1.2 11.1 5.3 56 11 61 165 3.2 0 3.3 3.3 12/05/2005 08:30:00 8.4 1.2 11.8 5.3 8.4 1.3 11.8 5.3 7.9 1.1 10.7 5.3 53 12 64 165 3.3 0 3.5 3.3 12/05/2005 08:40:00 8 1.5 13 4.9 8 1.7 13.7 4.9 7.6 1.7 11.8 4.2 46 12 74 165 3.3 0 3.5 3.3 12/05/2005 08:50:00 7.8 1.6 12.2 4.9 7.8 1.7 12.2 4.6 7.4 1.4 11.5 4.9 44 11 53 165 3.4 0 3.5 3.3 12/05/2005 09:00:00 7.4 1.2 10.7 4.6 7.4 1.3 10.7 4.2 7 1.3 10.7 4.2 47 11 42 165 3.5 0 3.5 3.3 12/05/2005 09:10:00 7.5 1.5 12.6 4.2 7.5 1.6 12.6 4.2 7.3 1.5 12.2 3.8 48 10 58 165 3.5 0 3.8 3.5 12/05/2005 09:20:00 9 1.7 12.6 4.9 9.1 1.8 12.6 4.6 8.6 1.9 13 4.2 49 10 51 165 3.6 0 3.8 3.5 12/05/2005 09:30:00 8 1.2 12.2 4.9 8 1.3 12.2 4.9 7.5 1.3 10.7 4.9 50 11 68 165 3.6 0 3.8 3.5 12/05/2005 09:40:00 7.8 1 10.3 5.7 7.8 1 10.3 5.3 7.4 1 10.3 4.6 40 9 59 165 3.6 0 3.8 3.5 12/05/2005 09:50:00 8.2 1.2 12.6 5.3 8.2 1.2 12.2 5.3 7.7 1.1 10.7 5.3 42 10 29 165 3.7 0 3.8 3.5 12/05/2005 10:00:00 8 1.5 13 4.9 8 1.5 12.6 4.9 7.6 1.5 12.6 4.2 42 10 49 165 3.8 0 3.8 3.8 12/05/2005 10:10:00 8.7 1.7 12.2 4.6 8.7 1.8 12.6 4.6 8.2 1.7 11.8 4.2 46 11 39 165 3.9 0 4 3.8 12/05/2005 10:20:00 7.7 1.4 10.7 4.6 7.6 1.4 10.7 4.6 7.2 1.3 11.1 4.6 45 11 39 165 3.9 0 4 3.8 12/05/2005 10:30:00 7 1.3 11.5 4.6 7 1.5 10.7 4.2 6.5 1.3 10.7 3.8 51 11 55 165 4 0 4.3 3.8 12/05/2005 10:40:00 7.3 1.5 11.8 4.6 7.3 1.5 11.8 4.2 6.9 1.3 11.5 3.8 51 10 52 165 4 0 4.3 3.8 12/05/2005 10:50:00 7.9 1.4 11.5 4.6 7.9 1.5 11.8 4.2 7.5 1.4 11.5 3.8 46 10 55 165 4.1 0.1 4.3 3.8 12/05/2005 11:00:00 7.4 1 10.7 5.3 7.4 1.1 10.7 4.9 7 1 10.7 4.6 43 9 52 165 4.1 0 4.3 4.3 12/05/2005 11:10:00 7.5 1.3 11.1 4.9 7.4 1.3 11.1 4.9 7.1 1.2 10.7 4.6 42 10 45 165 4.1 0 4.3 4.3 12/05/2005 11:20:00 7.9 1.3 11.8 5.3 7.8 1.3 11.1 4.9 7.7 1.3 11.1 4.9 42 9 39 165 4.3 0 4.5 4.3 12/05/2005 11:30:00 8 1.3 11.5 4.6 8 1.5 11.8 4.6 7.4 1.3 11.5 4.6 48 10 56 165 4.3 0 4.5 4.3 12/05/2005 11:40:00 8 1.2 11.1 4.9 8 1.3 11.1 4.9 7.7 1.2 11.5 4.9 44 10 34 165 4.3 0 4.5 4.3 12/05/2005 11:50:00 7.5 1.1 10.3 4.2 7.4 1.1 10.7 4.2 7.3 1 10.3 4.6 43 7 44 165 4.3 0 4.5 4.3 12/05/2005 12:00:00 7.3 1 9.9 4.9 7.2 1 9.9 4.9 7 1 10.3 4.2 44 9 39 165 4.3 0 4.5 4.3 12/05/2005 12:10:00 7.6 1.2 10.3 4.6 7.6 1.3 10.7 4.2 7.2 1.1 10.3 4.2 47 9 53 165 4.4 0 4.8 4.3 12/05/2005 12:20:00 7.4 1 9.5 5.3 7.5 1 9.5 5.3 7 0.9 9.5 5.3 57 9 65 165 4.6 0 4.8 4.5 12/05/2005 12:30:00 7.8 1 9.9 5.3 8 1 10.3 5.3 7.4 0.9 9.9 4.6 61 6 63 165 4.6 0 4.8 4.5 12/05/2005 12:40:00 7.5 0.9 9.9 5.3 7.6 1 10.3 5.3 7 1 9.9 4.9 65 7 69 165 4.6 0 4.8 4.5 12/05/2005 12:50:00 8.4 1.1 10.7 5.3 8.5 1.1 10.7 5.7 7.9 1.1 10.3 5.3 74 7 78 165 4.8 0 5 4.8 12/05/2005 13:00:00 9.1 0.7 10.7 6.8 9.3 0.8 11.1 7.2 8.5 0.8 10.3 6.1 86 6 84 165 4.9 0 5 4.8 12/05/2005 13:10:00 9.2 0.6 10.7 7.2 9.4 0.6 10.7 7.2 8.7 0.8 10.3 6.1 93 4 96 165 5.1 0 5.2 5 12/05/2005 13:20:00 8.9 0.5 10.3 7.6 9.1 0.5 10.7 7.6 8.4 0.6 9.9 6.5 94 4 90 165 5.1 0 5.2 5 12/05/2005 13:30:00 8.7 0.6 9.9 6.5 8.8 0.6 10.3 6.5 8.1 0.8 9.5 5.7 98 6 92 165 5.2 0 5.2 5 12/05/2005 13:40:00 8.5 0.5 9.9 7.2 8.6 0.5 9.9 7.2 7.9 0.7 9.1 4.9 101 4 106 165 5.2 0 5.2 5 12/05/2005 13:50:00 8.6 0.6 10.7 7.2 8.8 0.6 10.3 7.2 8.1 0.8 10.3 5.3 105 5 111 165 5.2 0 5.2 5 12/05/2005 14:00:00 8.5 0.5 9.9 6.8 8.6 0.6 10.3 6.8 8.1 0.7 9.9 5.7 111 5 114 165 5.2 0 5.2 5.2 12/05/2005 14:10:00 8.5 0.8 11.1 5.7 8.6 0.8 11.1 6.1 8 1 11.1 5.3 113 5 123 165 5.2 0 5.2 5.2 12/05/2005 14:20:00 8.6 0.7 10.7 6.5 8.8 0.7 10.7 6.5 8.3 0.8 9.9 5.3 109 5 110 165 5.2 0 5.5 5.2 12/05/2005 14:30:00 8.3 0.6 10.3 6.5 8.4 0.6 10.7 6.1 7.4 0.8 9.1 4.9 101 5 104 165 5.2 0 5.2 5 12/05/2005 14:40:00 8.6 0.6 9.9 6.1 8.7 0.6 10.3 6.8 7.9 0.8 9.5 5.3 99 4 99 165 5.1 0 5.2 5 12/05/2005 14:50:00 9.1 0.8 11.1 6.5 9.2 0.8 11.1 6.5 8.4 1 10.3 5.3 101 5 105 165 5.1 0 5.2 5 12/05/2005 15:00:00 9.3 0.8 11.5 5.3 9.4 0.9 11.5 6.1 8.6 1 10.7 6.1 104 4 104 165 5.1 0 5.2 5 12/05/2005 15:10:00 9.9 0.8 11.8 6.8 10.1 0.8 11.8 7.2 9.3 1 11.8 6.5 107 5 108 165 5.1 0 5.2 5 12/05/2005 15:20:00 9.8 0.7 12.2 7.6 10 0.7 12.6 7.2 9 1 11.5 6.5 105 5 100 165 5.2 0 5.2 5 12/05/2005 15:30:00 10.1 0.7 11.8 8 10.3 0.7 11.8 8.4 9.5 1 11.5 6.5 109 4 104 165 5.2 0 5.2 5 12/05/2005 15:40:00 10.2 0.9 12.6 7.2 10.4 0.9 12.6 7.6 9.7 1 12.2 6.8 109 5 102 165 5.2 0 5.5 5 12/05/2005 15:50:00 10.3 0.9 12.6 7.2 10.4 1 12.6 6.8 9.6 1.1 12.2 6.1 107 6 103 165 5.2 0 5.5 5.2 12/05/2005 16:00:00 10.4 0.9 13 8 10.5 1 13 8 9.6 1.1 12.2 6.8 109 5 111 165 5.2 0 5.5 5.2 12/05/2005 16:10:00 11.3 0.9 13.3 8 11.5 0.9 13.3 8.4 10.7 1.1 13 7.6 108 5 106 165 5.2 0 5.5 5.2 12/05/2005 16:20:00 11.8 1.2 15.3 8.8 11.9 1.2 15.6 8.8 10.9 1.5 14.9 7.2 107 7 112 165 5.2 0 5.5 5.2 12/05/2005 16:30:00 12.6 1.3 15.3 7.6 12.8 1.3 15.6 8.4 11.9 1.5 14.9 6.8 104 7 98 165 5.2 0 5.5 5.2 12/05/2005 16:40:00 12.7 1.3 16.1 8.8 12.8 1.3 16.4 8.8 11.5 1.4 15.3 7.6 100 6 102 165 5.2 0 5.5 5 12/05/2005 16:50:00 12.8 1.1 15.3 8.8 13 1.2 15.3 8.8 11.8 1.3 14.9 7.6 100 6 102 165 5.2 0 5.5 5.2 12/05/2005 17:00:00 13.3 1.5 16.8 9.1 13.5 1.5 17.6 9.5 12.3 1.5 16.1 7.2 100 6 102 165 5.2 0 5.5 5.2 12/05/2005 17:10:00 13.2 1.4 16.4 9.1 13.4 1.4 17.2 9.1 12.3 1.6 15.3 7.6 103 7 105 165 5.2 0 5.5 5.2 12/05/2005 17:20:00 13.6 1.3 16.4 9.1 13.8 1.3 16.8 9.1 12.7 1.5 16.1 8.8 103 5 105 165 5.3 0 5.5 5 12/05/2005 17:30:00 12.8 1.7 16.4 7.2 12.9 1.7 16.4 7.2 11.6 1.8 16.1 8 102 6 98 165 5.2 0 5.5 5.2 12/05/2005 17:40:00 13.3 1.3 16.1 9.1 13.5 1.3 16.4 9.5 12.1 1.5 15.3 8.4 102 7 102 165 5.4 0 5.5 5.2 12/05/2005 17:50:00 13.4 1.3 16.1 9.5 13.6 1.3 16.8 10.3 12.5 1.5 15.6 8.4 106 5 107 165 5.4 0 5.5 5.2 12/05/2005 18:00:00 13.3 1.3 17.2 9.1 13.5 1.3 17.2 9.5 12.4 1.3 16.4 9.1 105 6 109 165 5.5 0 5.7 5.5 12/05/2005 18:10:00 13.5 1.4 17.6 9.1 13.7 1.4 17.9 9.5 12.8 1.5 17.2 8.8 106 6 104 165 5.6 0 5.7 5.5 12/05/2005 18:20:00 13.7 1.2 16.8 8.4 13.9 1.1 16.8 8.4 13 1.4 16.8 8.4 107 5 105 165 5.6 0 5.7 5.5 12/05/2005 18:30:00 14.2 1.1 16.8 10.3 14.4 1.1 17.6 10.3 13.3 1.3 16.1 8.8 104 5 106 165 5.6 0 5.7 5.5 12/05/2005 18:40:00 13.6 1.4 17.6 10.3 13.8 1.4 17.9 9.9 12.7 1.5 16.8 8.4 103 6 109 165 5.5 0 5.7 5.5 12/05/2005 18:50:00 13.8 1.5 17.9 9.5 14 1.5 18.3 9.5 12.9 1.7 17.9 8.4 103 7 106 165 5.6 0 5.7 5.5 12/05/2005 19:00:00 12.8 1.5 16.4 8.4 13 1.6 17.2 8 12 1.6 15.3 8 103 7 101 165 5.5 0 5.7 5.5 12/05/2005 19:10:00 12.9 1.1 15.6 9.1 13.1 1.2 16.1 9.1 12.1 1.4 16.8 7.6 105 6 101 165 5.5 0 5.7 5.5 12/05/2005 19:20:00 13.6 1.5 18.3 9.5 13.8 1.5 19.1 10.3 12.9 1.5 16.8 9.1 106 7 104 165 5.6 0 5.7 5.5 12/05/2005 19:30:00 13.6 1.5 17.2 9.1 13.9 1.6 17.6 9.1 12.9 1.8 17.9 8 106 7 116 165 5.6 0 5.7 5.5 12/05/2005 19:40:00 13.4 1.8 18.3 8.4 13.6 1.9 19.1 8 12.6 2.2 20.6 7.2 107 8 105 165 5.6 0 5.7 5.5 12/05/2005 19:50:00 13.2 1.5 17.6 9.1 13.4 1.5 17.6 9.1 12.5 1.6 17.2 8.4 107 7 106 165 5.6 0 5.7 5.5 12/05/2005 20:00:00 13.3 1.7 17.9 8 13.6 1.7 17.9 8.4 12.5 1.7 17.6 8.8 110 7 113 165 5.7 0 5.7 5.5 12/05/2005 20:10:00 14.1 1.8 19.5 8.4 14.3 1.8 19.5 8.4 13.3 2 19.9 8.4 112 7 120 165 5.6 0 5.7 5.5 12/05/2005 20:20:00 14 1.5 18.3 9.1 14.2 1.6 18.7 9.1 13.1 1.7 17.2 8.8 113 7 116 165 5.6 0 5.7 5.5 12/05/2005 20:30:00 14.1 1.4 18.7 9.9 14.3 1.5 19.5 10.3 13.6 1.6 19.1 9.1 117 7 111 165 5.6 0 5.7 5.5 12/05/2005 20:40:00 14.9 1.6 20.2 10.3 15.1 1.6 20.2 10.3 14.2 1.7 19.5 9.5 118 7 126 165 5.6 0 5.7 5.5 12/05/2005 20:50:00 15 1.6 19.9 9.1 15.2 1.6 20.2 9.9 14.4 1.7 19.5 9.9 119 8 106 165 5.6 0 5.7 5.5 12/05/2005 21:00:00 15.1 1.8 21 9.5 15.4 1.8 21 9.9 14.7 2.1 21.4 8.4 122 7 124 165 5.6 0 5.7 5.5 12/05/2005 21:10:00 15.7 1.7 20.6 11.1 15.9 1.7 20.6 11.1 15.4 1.9 21 10.7 124 8 126 165 5.6 0 5.7 5.5 12/05/2005 21:20:00 15.3 1.5 19.9 11.5 15.5 1.6 20.2 11.8 14.8 1.7 19.9 10.7 124 8 118 165 5.6 0 5.7 5.5 12/05/2005 21:30:00 15.4 2.1 22.1 9.9 15.6 2.1 22.1 9.9 15.1 2.3 21.4 9.5 125 7 118 165 5.6 0 5.7 5.5 12/05/2005 21:40:00 16.1 1.7 21.4 11.5 16.3 1.7 21.8 12.2 16 1.7 21 11.5 124 7 115 165 5.7 0 5.7 5.7 12/05/2005 21:50:00 16.4 1.8 21 12.2 16.6 1.8 21 11.8 15.9 1.9 20.6 10.3 126 8 130 165 5.7 0 5.7 5.5 12/05/2005 22:00:00 16 1.6 20.2 9.9 16.1 1.7 19.9 9.5 15.6 1.7 19.9 10.3 127 8 129 165 5.7 0 5.7 5.5 12/05/2005 22:10:00 15.4 1.4 19.5 11.8 15.6 1.4 19.5 12.2 15 1.6 19.1 10.7 127 7 121 165 5.7 0 5.7 5.5 12/05/2005 22:20:00 15 1.7 21 10.7 15.1 1.7 21.4 10.3 14.5 1.8 19.5 9.5 129 9 139 165 5.6 0 5.7 5.5 12/05/2005 22:30:00 14.8 1.7 18.7 10.7 14.9 1.7 19.1 10.3 14.5 1.7 18.7 10.3 132 7 139 165 5.7 0 5.7 5.5 12/05/2005 22:40:00 14.4 1.7 19.9 10.3 14.5 1.7 20.2 10.3 14.1 1.9 20.2 8.4 130 8 121 165 5.7 0 5.7 5.5 12/05/2005 22:50:00 14.4 1.6 18.3 10.3 14.5 1.5 18.3 11.1 14 1.5 17.6 9.5 131 7 139 165 5.6 0 5.7 5.5 12/05/2005 23:00:00 13.5 1.2 16.8 10.3 13.6 1.2 17.2 9.9 13 1.3 16.4 9.5 131 7 128 165 5.6 0 5.7 5.5 12/05/2005 23:10:00 13.7 1.6 18.3 9.5 13.8 1.6 18.3 9.5 13.3 1.8 18.7 8 131 7 119 165 5.7 0 5.7 5.5 12/05/2005 23:20:00 13.9 1.3 17.6 10.3 14 1.3 17.9 10.3 13.7 1.5 17.6 9.1 131 7 116 165 5.7 0 5.7 5.5 12/05/2005 23:30:00 13.3 1.5 17.2 8.4 13.4 1.5 17.2 9.1 12.8 1.6 17.2 9.1 131 10 133 165 5.7 0 5.7 5.5 12/05/2005 23:40:00 13.5 1.7 18.7 10.3 13.7 1.7 19.1 10.3 13.2 1.9 18.3 8.4 131 8 128 165 5.7 0 5.7 5.5 12/05/2005 23:50:00 13.9 1.3 17.2 10.3 14 1.3 17.2 10.3 13.6 1.6 16.8 8.8 128 8 121 165 5.7 0 5.7 5.5 12/06/2005 00:00:00 13.4 1.4 17.2 10.3 13.5 1.4 17.2 10.3 13.1 1.5 17.2 9.5 128 7 144 165 5.7 0 5.7 5.5 12/06/2005 00:10:00 13.7 1.4 17.6 8.8 13.9 1.4 17.6 9.1 13.4 1.6 17.6 9.9 126 7 114 165 5.7 0 5.7 5.5 12/06/2005 00:20:00 13.2 1.5 17.9 9.5 13.4 1.5 17.9 9.5 12.9 1.7 17.2 8.4 127 8 118 165 5.7 0 5.7 5.7 12/06/2005 00:30:00 13.5 1.4 17.6 9.5 13.7 1.4 17.9 9.9 13.2 1.3 17.2 9.5 128 6 140 165 5.7 0 5.7 5.7 12/06/2005 00:40:00 13.9 1.5 17.9 9.9 14 1.4 17.6 9.5 13.4 1.6 17.6 9.1 129 8 135 165 5.7 0 5.7 5.7 12/06/2005 00:50:00 14.2 1.5 17.6 9.9 14.4 1.5 17.9 9.9 14.1 1.5 17.6 9.1 128 7 117 165 5.7 0 5.7 5.7 12/06/2005 01:00:00 13.1 1.5 17.6 9.5 13.3 1.5 17.6 9.5 13 1.5 17.9 8.4 130 7 133 165 5.7 0 5.7 5.7 12/06/2005 01:10:00 13.1 1.2 15.6 9.1 13.3 1.2 16.1 9.9 12.8 1.4 16.4 9.1 130 7 136 165 5.7 0 5.7 5.7 12/06/2005 01:20:00 13.5 1.1 16.4 9.9 13.6 1.1 16.4 10.7 13.3 1.2 16.8 9.1 130 8 122 165 5.7 0 5.7 5.7 12/06/2005 01:30:00 12.1 1.3 15.3 9.1 12.2 1.3 15.6 9.1 11.8 1.4 15.3 8 133 8 125 165 5.7 0 5.7 5.7 12/06/2005 01:40:00 12.5 1.2 16.1 9.1 12.6 1.2 16.4 8.4 12.2 1.3 16.4 8.8 128 8 126 165 5.7 0 5.7 5.5 12/06/2005 01:50:00 12.8 1.3 16.4 9.1 13 1.2 16.8 9.1 12.7 1.2 15.6 9.1 129 8 136 165 5.7 0 5.7 5.7 12/06/2005 02:00:00 13.4 1.2 16.4 10.7 13.6 1.2 16.4 10.7 13.2 1.3 16.4 9.1 130 6 126 165 5.7 0 5.7 5.7 12/06/2005 02:10:00 13.1 1.1 15.6 9.9 13.3 1 15.6 9.9 13 1.1 15.6 9.1 130 6 122 165 5.6 0 5.7 5.5 12/06/2005 02:20:00 13.5 1.2 16.4 9.1 13.7 1.3 16.4 9.1 13.2 1.3 16.1 8.4 129 6 131 165 5.6 0 5.7 5.5 12/06/2005 02:30:00 12.8 1.3 16.4 8.8 12.9 1.4 16.8 9.1 12.5 1.4 16.1 8.8 129 7 133 165 5.6 0 5.7 5.5 12/06/2005 02:40:00 12.3 1.2 16.1 8.8 12.4 1.2 16.4 8.8 12 1.3 15.3 8.8 132 6 132 165 5.6 0 5.7 5.5 12/06/2005 02:50:00 11.7 1.3 15.3 9.5 11.8 1.3 15.3 8.8 11.4 1.3 14.9 8.4 134 7 126 165 5.6 0 5.7 5.5 12/06/2005 03:00:00 10.9 1.3 15.3 8 10.9 1.4 15.6 7.6 10.7 1.4 14.1 6.8 133 8 126 165 5.6 0 5.7 5.5 12/06/2005 03:10:00 11 1.2 13.7 7.6 11.1 1.2 14.1 8 10.7 1.3 14.1 7.2 133 7 140 165 5.6 0 5.7 5.2 12/06/2005 03:20:00 10.4 1.2 13 7.2 10.5 1.2 13.3 6.8 10.1 1.2 13.3 6.8 135 8 138 165 5.5 0 5.7 5.5 12/06/2005 03:30:00 9.9 0.8 11.8 7.6 9.9 0.8 11.8 7.6 9.7 0.8 12.2 7.2 137 7 141 165 5.5 0 5.7 5.2 12/06/2005 03:40:00 9.2 1 11.5 6.5 9.2 1 11.5 6.5 8.8 1.1 10.7 5.7 137 6 125 165 5.4 0 5.5 5.5 12/06/2005 03:50:00 8.3 1 10.7 5.7 8.4 1 10.7 5.7 8.1 1 10.3 4.9 136 6 135 165 5.4 0 5.5 5.2 12/06/2005 04:00:00 8.2 0.9 10.3 6.1 8.2 1 10.3 5.7 8 1 9.9 5.3 134 6 117 165 5.4 0 5.5 5 12/06/2005 04:10:00 6.9 0.7 8.4 4.9 6.8 0.7 8 4.9 6.6 0.8 8 4.6 136 6 133 165 5.2 0 5.5 5 12/06/2005 04:20:00 5.5 0.5 6.8 3.8 5.4 0.5 6.8 3.8 5.2 0.5 6.5 3.8 134 5 137 165 5.2 0 5.2 5.2 12/06/2005 04:30:00 5 0.5 6.1 3.8 5 0.5 6.1 3.4 4.8 0.5 5.7 3.4 132 6 133 165 5.2 0 5.5 5 12/06/2005 04:40:00 4.8 0.3 5.3 3.4 4.7 0.3 5.7 3.4 4.6 0.4 5.3 3.4 126 5 127 165 5.2 0 5.2 5 12/06/2005 04:50:00 4.6 0.5 5.7 3.4 4.6 0.5 5.7 3 4.4 0.5 5.7 3.4 133 6 132 165 5.1 0 5.2 5 12/06/2005 05:00:00 5.7 0.5 6.5 4.2 5.6 0.5 6.5 4.2 5.5 0.6 6.5 4.2 145 5 143 165 5 0 5 5 12/06/2005 05:10:00 6.1 0.3 6.8 5.3 5.9 0.2 6.5 5.3 5.9 0.3 6.5 5.3 152 3 148 165 4.9 0 5 5 12/06/2005 05:20:00 4.7 0.9 6.1 3 4.4 0.9 5.7 3 4.6 0.8 6.1 2.6 160 5 158 165 4.9 0 5 4.8 12/06/2005 05:30:00 4 0.6 5.3 3 3.8 0.6 4.9 2.6 3.8 0.5 5.3 2.6 161 10 163 165 4.8 0.1 5 4.8 12/06/2005 05:40:00 3 0.5 4.2 1.9 2.8 0.5 4.2 1.5 2.7 0.5 4.2 1.5 162 3 158 165 4.8 0 5 4.8 12/06/2005 05:50:00 2.4 0.5 3.4 1.1 2.2 0.5 3 1.1 2.4 0.6 3.4 1.5 162 3 164 165 5 0 5 5 12/06/2005 06:00:00 3.1 0.6 4.2 1.5 2.9 0.5 3.8 1.5 2.9 0.5 3.8 1.5 169 6 165 165 5 0 5.2 5 12/06/2005 06:10:00 3.5 0.6 4.9 1.9 3.2 0.6 4.6 1.9 3.3 0.5 4.6 2.3 172 6 176 165 4.9 0 5 4.8 12/06/2005 06:20:00 5.1 0.5 6.1 3.4 4.8 0.5 6.1 3.4 4.9 0.5 6.1 3.4 169 7 173 165 4.8 0.1 5 4.5 12/06/2005 06:30:00 6.6 0.5 7.2 4.9 6.2 0.4 6.8 4.6 6.3 0.5 7.2 4.9 171 3 174 165 4.6 0 4.8 4.5 12/06/2005 06:40:00 6.1 0.3 6.8 5.3 5.7 0.3 6.5 4.9 5.9 0.3 6.8 4.9 172 4 176 165 4.6 0 4.8 4.5 12/06/2005 06:50:00 5.4 0.3 6.1 4.6 5.1 0.3 5.7 4.6 5.2 0.3 6.1 4.6 171 3 173 165 4.6 0 4.8 4.5 12/06/2005 07:00:00 4.7 0.5 6.1 3.4 4.5 0.5 5.7 3.4 4.5 0.5 5.7 3.4 175 8 173 165 4.6 0 4.8 4.5 12/06/2005 07:10:00 3.2 0.5 4.9 1.9 3 0.5 4.6 1.9 3.1 0.5 4.6 1.9 178 7 182 165 4.7 0 4.8 4.5 12/06/2005 07:20:00 4.8 0.7 6.1 2.6 4.6 0.8 6.1 2.3 4.4 0.7 6.1 2.3 189 10 201 165 4.6 0 4.8 4.5 12/06/2005 07:30:00 6 0.5 7.2 4.6 5.8 0.5 7.2 4.6 6.1 0.5 7.2 4.9 188 4 190 165 4.6 0 4.8 4.5 12/06/2005 07:40:00 6.7 0.7 8 5.3 6.4 0.7 8 4.9 6.5 0.7 8 4.9 189 6 195 165 4.6 0 4.8 4.5 12/06/2005 07:50:00 6.9 1.3 10.7 4.9 6.8 1.3 10.7 4.6 6.9 1.4 11.1 4.2 189 7 179 165 4.6 0 4.8 4.5 12/06/2005 08:00:00 7.9 0.8 9.9 5.7 7.7 0.7 9.5 5.7 7.9 0.8 10.3 6.1 185 6 186 165 4.6 0 4.8 4.5 12/06/2005 08:10:00 8 0.6 9.1 6.5 7.8 0.6 8.8 6.1 8 0.7 9.9 6.5 181 5 190 165 4.7 0 4.8 4.5 12/06/2005 08:20:00 6.2 1.1 8.8 4.6 6 1.1 8.8 4.6 6 1.2 8.8 3.8 183 4 181 165 4.7 0 4.8 4.5 12/06/2005 08:30:00 5.4 0.7 7.2 3.4 5.1 0.6 6.8 3.4 5.1 0.6 6.8 3.4 177 6 167 165 4.7 0 4.8 4.8 12/06/2005 08:40:00 6.3 0.5 7.6 4.9 6.1 0.5 7.2 4.9 6.2 0.5 7.2 5.3 159 10 180 165 4.7 0.1 5 4.5 12/06/2005 08:50:00 5.5 1 8 3.8 5.3 0.9 7.6 3.4 5.4 1 8 3.4 171 10 176 165 4.6 0 4.8 4.5 12/06/2005 09:00:00 5.8 0.8 7.6 3.8 5.5 0.8 7.2 3.4 5.5 1.1 7.6 2.6 180 8 181 165 4.7 0 5 4.5 12/06/2005 09:10:00 4.1 0.5 5.7 2.6 3.9 0.5 5.3 2.6 3.9 0.6 5.7 2.3 179 7 185 165 4.8 0 5 4.8 12/06/2005 09:20:00 5.1 0.7 6.8 2.6 4.9 0.8 6.8 3 4.7 0.8 6.5 3 188 13 198 165 4.7 0 5 4.5 12/06/2005 09:30:00 4.9 0.8 6.8 2.6 4.9 0.8 6.8 2.6 4.6 0.7 6.5 3 210 8 204 165 4.8 0.1 5 4.8 12/06/2005 09:40:00 6.3 1.1 9.5 4.2 6.4 1.1 9.1 4.2 5.8 1 8.4 4.2 230 8 233 165 4.9 0.2 5.2 4.8 12/06/2005 09:50:00 6.2 0.8 8 4.2 6.3 0.8 8.4 4.6 5.9 0.9 8.8 4.2 221 5 228 165 5.1 0 5.2 5 12/06/2005 10:00:00 6.1 0.6 8 3.8 6.2 0.6 8.4 4.2 5.8 0.7 8 3.8 218 6 222 165 5.2 0 5.5 5 12/06/2005 10:10:00 6.1 0.8 8.4 4.2 6.2 0.8 8.4 4.2 5.9 0.8 7.6 3.8 219 6 217 165 5.4 0 5.5 5.2 12/06/2005 10:20:00 6.2 0.8 8 4.2 6.3 0.8 8 4.2 6 0.8 8 4.2 219 5 215 165 5.5 0 5.7 5.5 12/06/2005 10:30:00 6.4 0.8 8.4 3.8 6.5 0.8 8.8 4.2 6.1 0.9 8.4 3.8 216 6 214 165 5.7 0 6 5.5 12/06/2005 10:40:00 5.6 0.9 8 3.4 5.6 0.9 8 3.8 5.3 0.8 7.2 3.4 211 6 207 165 6 0 6.2 5.7 12/06/2005 10:50:00 4.2 0.8 6.1 2.6 4.1 0.8 6.1 2.3 4.1 0.6 5.7 2.6 190 12 199 165 6.2 0 6.5 6 12/06/2005 11:00:00 3.5 0.6 5.3 1.5 3.3 0.6 5.3 0.7 3.3 0.6 4.6 1.5 178 17 230 165 6.4 0 6.7 6.2 12/06/2005 11:10:00 3.5 0.8 5.3 1.5 3.3 0.8 5.7 1.5 3.4 0.8 6.1 1.5 165 12 165 165 6.6 0 6.7 6.2 12/06/2005 11:20:00 3.3 0.9 6.1 1.5 3.2 0.9 6.1 1.1 3.3 1.1 7.2 1.1 171 20 165 165 6.4 0.1 6.7 6.2 12/06/2005 11:30:00 4.6 0.8 6.5 2.6 4.4 0.8 6.5 2.3 4.4 1 6.5 1.1 189 14 205 165 6.4 0.1 6.7 6.2 12/06/2005 11:40:00 6.2 1.2 9.1 3.4 6.2 1.3 9.1 3.4 6.2 1.2 9.1 3.4 191 13 206 165 6.2 0 6.5 6 12/06/2005 11:50:00 7.3 0.9 9.5 4.6 7.2 0.9 9.5 4.6 7.3 0.9 9.5 4.9 190 13 190 165 5.9 0.1 6.2 5.7 12/06/2005 12:00:00 7.7 1.2 10.7 4.9 7.6 1.1 10.3 4.6 7.7 1.1 10.7 4.9 191 12 184 165 6 0 6.2 5.7 12/06/2005 12:10:00 6.9 0.9 9.5 4.2 6.9 0.9 9.5 4.2 6.5 0.8 9.1 3.8 192 8 204 165 6.2 0.1 6.5 6 12/06/2005 12:20:00 6.8 0.9 9.1 4.2 6.7 0.9 8.8 4.2 6.6 1 8.8 3.8 196 8 203 165 6.3 0 6.5 6.2 12/06/2005 12:30:00 7 1.1 9.5 3.8 7 1.1 9.9 3.8 7 1 9.5 4.6 192 11 202 165 6.3 0 6.2 6 12/06/2005 12:40:00 6.7 1.6 11.1 3.8 6.6 1.6 11.1 3.4 6.7 1.7 11.1 3.8 190 10 196 165 6.4 0 6.5 6.2 12/06/2005 12:50:00 7.3 1 10.3 4.6 7.4 1 10.3 4.9 7.3 1.1 10.3 4.6 198 9 201 165 6.3 0 6.7 6.2 12/06/2005 13:00:00 6.8 0.7 8.8 4.2 6.8 0.8 8.8 4.2 6.7 0.7 9.1 4.6 197 9 210 165 6.4 0 6.7 6.2 12/06/2005 13:10:00 7.5 0.9 9.5 5.3 7.4 0.9 9.1 5.3 7.4 1 9.5 4.9 191 6 204 165 6.5 0 6.7 6.2 12/06/2005 13:20:00 7.1 0.6 8.8 5.3 7 0.6 8.8 4.9 7.1 0.7 9.5 5.3 191 7 195 165 6.4 0 6.7 6.2 12/06/2005 13:30:00 5.4 0.9 7.6 3.8 5.2 0.9 7.2 3.8 5.4 0.9 8 4.2 180 11 183 165 6.6 0 7 6.2 12/06/2005 13:40:00 5.8 0.7 7.6 3.4 5.6 0.7 7.2 3.4 5.8 0.8 8 3.4 177 9 171 165 6.6 0 7.3 6.2 12/06/2005 13:50:00 6 1 8.4 3 5.9 0.9 8.4 3 5.8 0.9 8 2.6 185 11 191 165 6.4 0 6.7 6 12/06/2005 14:00:00 5.8 0.7 7.6 4.2 5.7 0.7 7.6 4.2 5.9 0.8 7.6 4.2 188 10 189 165 5.9 0.2 6.2 5.5 12/06/2005 14:10:00 6.5 0.9 9.5 4.2 6.4 0.9 9.1 4.2 6.5 1 8.4 4.2 191 9 167 165 5.2 0.1 5.5 5 12/06/2005 14:20:00 8.2 0.8 9.9 6.1 8 0.8 9.9 5.7 8.3 0.9 10.7 6.5 186 8 183 165 5.2 0 5.2 4.8 12/06/2005 14:30:00 7.5 1.1 10.3 4.9 7.3 1.1 10.7 4.9 7.7 1.2 11.5 4.9 181 8 172 165 5.2 0 5.2 5 12/06/2005 14:40:00 7.2 1.2 9.5 3.4 7.1 1.2 9.5 3.8 7.4 1.2 10.3 4.9 180 9 172 165 5.1 0 5.2 5 12/06/2005 14:50:00 7 0.6 8.8 5.7 6.8 0.6 8.8 5.3 7.1 0.7 9.1 5.7 184 5 184 165 5 0 5.2 4.8 12/06/2005 15:00:00 7 1.2 9.5 4.6 6.7 1.2 9.1 4.6 7 1.1 9.9 4.6 175 8 165 165 5.1 0 5.2 5 12/06/2005 15:10:00 6.2 0.8 8 4.6 6 0.8 8 4.2 6.2 0.9 8.4 3.4 174 9 169 165 5.1 0 5.2 4.8 12/06/2005 15:20:00 4.7 1.3 8 1.9 4.5 1.2 7.6 2.3 4.5 1.3 7.2 1.9 184 13 180 165 5.2 0 5.5 5 12/06/2005 15:30:00 5.2 1.1 8 2.3 5 1 7.2 1.9 5.2 1 7.6 2.6 172 11 176 165 5.1 0 5.2 4.8 12/06/2005 15:40:00 7.1 1.2 9.9 4.2 6.9 1.2 9.5 4.2 7 1.1 9.9 4.6 176 8 188 165 5 0 5.2 4.8 12/06/2005 15:50:00 8.6 1 11.1 5.3 8.4 1 10.7 4.9 8.6 1.1 11.1 5.3 185 6 191 165 4.9 0 5 4.8 12/06/2005 16:00:00 6.9 0.7 8.8 5.3 6.8 0.7 8.4 4.9 6.7 0.7 8.4 4.9 192 6 185 165 4.9 0 5 4.8 12/06/2005 16:10:00 7.3 1 9.9 4.6 7.1 0.9 9.5 4.6 7 1 9.9 4.9 183 10 171 165 4.7 0 4.8 4.5 12/06/2005 16:20:00 9 1 11.1 6.5 8.9 1 11.1 6.1 8.9 1 11.8 6.5 188 8 197 165 4.7 0 5 4.8 12/06/2005 16:30:00 6.9 1.3 9.9 4.2 6.8 1.3 9.9 4.2 6.9 1.4 9.9 4.2 190 9 184 165 4.8 0 5 4.8 12/06/2005 16:40:00 7.3 1 9.5 4.6 7.1 1 9.5 4.6 7.1 1.1 9.9 4.2 192 9 183 165 4.6 0 4.8 4.5 12/06/2005 16:50:00 6.8 0.8 8.8 4.2 6.7 0.8 8.4 4.2 6.6 0.9 8.8 4.2 192 6 185 165 4.6 0 4.8 4.5 12/06/2005 17:00:00 4.1 0.9 6.5 1.9 4 0.9 6.5 1.9 3.9 0.9 6.1 2.3 181 14 197 165 4.3 0.1 4.8 4.3 12/06/2005 17:10:00 5 0.9 7.2 2.3 4.8 0.9 7.6 2.3 4.8 0.9 7.2 2.3 180 12 184 165 4.4 0 4.5 4.3 12/06/2005 17:20:00 7.7 1.3 11.1 4.9 7.5 1.3 11.1 4.2 7.6 1.3 10.7 5.3 184 8 185 165 4.3 0 4.5 4.3 12/06/2005 17:30:00 8.5 0.7 10.7 6.1 8.4 0.7 10.3 6.1 8.6 0.8 10.7 6.8 191 6 196 165 4.6 0 4.8 4.5 12/06/2005 17:40:00 7.3 0.6 9.5 5.7 7 0.5 9.1 5.7 7.3 0.6 9.1 6.1 173 6 188 165 4.3 0.2 4.8 4.3 12/06/2005 17:50:00 9.6 1 12.2 7.6 9.3 1 11.8 7.2 9.6 1 11.8 7.6 180 6 185 165 4.1 0 4.3 4 12/06/2005 18:00:00 10.8 0.8 12.6 8.4 10.6 0.8 12.2 8 11.1 0.9 13 9.1 184 5 179 165 4.3 0 4.5 4.3 12/06/2005 18:10:00 9 0.6 10.3 7.2 8.8 0.6 10.3 7.2 9.2 0.7 10.7 6.8 187 4 193 165 4.5 0 4.8 4.3 12/06/2005 18:20:00 6.8 1.2 9.5 3.8 6.7 1.2 9.5 3.8 6.9 1.2 9.1 4.2 185 7 189 165 4.5 0 4.8 4.5 12/06/2005 18:30:00 5.9 0.6 7.2 4.6 5.7 0.6 7.2 4.6 5.9 0.7 7.6 4.2 179 6 165 165 4.3 0 4.5 4.3 12/06/2005 18:40:00 5.9 0.6 7.6 4.2 5.7 0.6 7.2 3.8 5.7 0.6 7.2 4.2 176 5 180 165 4.1 0 4.3 4.3 12/06/2005 18:50:00 6.2 0.6 7.6 4.6 5.9 0.5 7.2 4.6 6.1 0.6 7.6 4.6 175 4 177 165 4.1 0 4.3 4.3 12/06/2005 19:00:00 5 0.5 6.5 3.8 4.7 0.5 6.1 3.8 5 0.5 6.1 3.8 169 8 177 165 4.1 0 4.3 3.8 12/06/2005 19:10:00 6.6 0.8 8 4.9 6.3 0.7 7.6 4.6 6.6 0.7 8.4 4.9 167 10 166 165 4.1 0 4.3 4 12/06/2005 19:20:00 7.5 0.8 9.1 5.7 7.1 0.7 8.8 5.3 7.5 0.7 9.1 5.7 171 5 174 165 4 0 4.3 3.8 12/06/2005 19:30:00 7.3 0.7 9.1 5.7 7.1 0.7 8.8 5.3 7.3 0.7 9.1 5.3 170 7 165 165 4 0 4.3 3.8 12/06/2005 19:40:00 8.2 0.9 10.3 5.7 7.9 0.8 9.5 5.7 8.2 0.8 9.9 6.1 162 6 172 165 4 0 4 3.8 12/06/2005 19:50:00 9.5 1.1 12.2 6.1 9.3 1.1 11.8 6.1 9.7 1 12.2 6.8 164 6 165 165 4 0 4.3 3.8 12/06/2005 20:00:00 11.2 0.6 12.6 9.1 10.8 0.6 12.2 9.1 10.9 0.7 12.6 9.1 166 6 167 165 4 0 4.3 3.8 12/06/2005 20:10:00 11.3 1.1 13 7.2 11.1 1.1 13 6.8 11.3 1.3 13 7.2 164 7 165 165 4 0 4.3 3.8 12/06/2005 20:20:00 10 0.7 12.2 8 9.7 0.7 11.8 7.6 10 0.7 12.6 7.6 163 11 174 165 4 0 4.3 3.8 12/06/2005 20:30:00 9.2 0.5 10.3 7.6 9 0.5 10.3 7.2 9.4 0.5 10.7 7.2 158 4 159 165 4 0 4.3 4 12/06/2005 20:40:00 8.1 0.4 9.1 7.2 7.9 0.4 9.1 7.2 8 0.5 9.5 6.5 153 3 157 165 4 0 4.3 3.8 12/06/2005 20:50:00 7 0.6 8.4 5.7 6.9 0.5 8 5.7 6.9 0.6 8 5.3 152 4 164 165 4 0 4.3 3.8 12/06/2005 21:00:00 8.3 0.6 10.3 7.2 8.1 0.6 10.3 6.5 8.2 0.6 9.9 6.8 150 3 158 165 4 0 4.3 3.8 12/06/2005 21:10:00 8.8 0.6 10.3 7.6 8.6 0.6 9.9 7.6 8.8 0.6 10.3 7.6 154 3 151 165 4 0 4.3 3.8 12/06/2005 21:20:00 9.4 0.6 10.7 8 9.2 0.5 10.3 8 9.3 0.6 10.7 7.6 156 4 154 165 4 0 4.3 4 12/06/2005 21:30:00 9.9 1 12.2 7.2 9.7 1 12.2 7.6 9.7 1 12.2 6.8 156 5 156 165 4 0 4.3 4 12/06/2005 21:40:00 12 0.9 14.1 9.9 11.9 0.9 13.7 9.9 11.6 1 14.1 9.1 150 2 148 165 4 0 4.3 3.8 12/06/2005 21:50:00 12.8 0.7 14.1 9.9 12.7 0.7 14.1 10.3 12.6 0.9 14.5 9.9 149 3 150 165 4.1 0 4.3 4 12/06/2005 22:00:00 13.1 0.3 14.5 12.2 13 0.3 14.5 12.2 13.1 0.5 14.5 11.5 152 1 153 165 4.1 0 4.3 3.8 12/06/2005 22:10:00 13.2 0.5 14.5 11.8 13.1 0.4 14.1 11.8 13.1 0.6 14.5 11.5 150 2 155 165 4.1 0 4.3 4 12/06/2005 22:20:00 13.4 0.5 15.3 11.8 13.4 0.5 14.9 11.8 13.3 0.6 14.9 11.1 149 3 148 165 4.1 0 4.3 4 12/06/2005 22:30:00 13.4 0.6 14.9 11.8 13.4 0.6 14.9 11.5 13.2 0.8 14.9 10.3 149 3 147 165 4.1 0 4.3 3.8 12/06/2005 22:40:00 14.3 0.9 16.4 12.2 14.3 0.8 16.1 11.8 14.1 0.9 16.4 11.8 150 2 153 165 4 0 4.3 3.8 12/06/2005 22:50:00 13.7 0.6 15.3 11.8 13.7 0.6 15.3 11.8 13.4 0.7 15.3 11.5 151 3 148 165 4 0 4.3 4 12/06/2005 23:00:00 13.9 0.8 15.6 11.8 13.9 0.7 15.6 11.5 13.7 0.8 15.3 11.1 150 2 150 165 4 0 4.3 3.8 12/06/2005 23:10:00 13.2 0.7 15.3 11.1 13.1 0.6 15.3 11.5 13 0.7 14.5 11.1 149 3 155 165 4 0 4.3 3.8 12/06/2005 23:20:00 11.4 1 13 9.5 11.4 0.9 13.3 9.1 11.2 1 13.3 8.8 146 3 148 165 4.1 0 4.3 4 12/06/2005 23:30:00 11.9 0.7 13.3 10.3 12 0.6 13.3 10.3 11.7 0.8 13.3 9.5 146 3 146 165 4 0 4.3 4 12/06/2005 23:40:00 12.1 0.7 13.7 10.3 12.1 0.7 14.1 10.3 12.1 0.8 14.1 10.3 148 3 148 165 4.1 0 4.3 4.3 12/06/2005 23:50:00 12.4 1 14.9 9.9 12.4 0.9 14.5 9.9 12.1 1 14.5 9.9 147 3 148 165 4.1 0 4.3 4.3 12/07/2005 00:00:00 12.1 1.2 15.6 9.5 12.1 1.1 15.3 9.1 11.9 1.2 15.3 8.4 145 6 145 165 4.2 0 4.5 4.3 12/07/2005 00:10:00 12.3 1.1 14.9 9.5 12.4 1.2 14.9 8.8 12.1 1.3 14.9 8.4 141 7 127 165 4.3 0 4.5 4.3 12/07/2005 00:20:00 12.4 1.5 16.4 8 12.4 1.5 16.1 8.4 12.2 1.6 16.8 8.4 137 7 150 165 4.3 0 4.5 4.3 12/07/2005 00:30:00 14.2 1.2 17.2 11.5 14.3 1.2 17.2 11.5 14 1.3 17.9 10.7 139 6 145 165 4.3 0 4.5 4.3 12/07/2005 00:40:00 15.4 1.2 18.3 12.6 15.5 1.2 18.3 12.6 15.2 1.5 18.3 11.1 139 7 135 165 4.4 0 4.5 4.3 12/07/2005 00:50:00 15.5 1 17.9 11.8 15.6 1.1 17.9 11.8 15.4 1.3 18.3 11.5 136 6 136 165 4.4 0 4.5 4.3 12/07/2005 01:00:00 14.9 1.5 18.7 11.5 15 1.5 19.1 11.8 14.8 1.6 19.5 10.3 136 7 136 165 4.4 0 4.5 4.3 12/07/2005 01:10:00 14.4 1.7 19.9 10.7 14.6 1.7 19.9 10.7 14.2 1.9 19.1 9.9 133 7 124 165 4.4 0 4.5 4.3 12/07/2005 01:20:00 14 1.2 17.2 11.1 14.1 1.1 17.2 11.1 13.7 1.3 16.8 9.9 130 8 117 165 4.5 0 4.5 4.5 12/07/2005 01:30:00 14 1.3 17.6 9.5 14.1 1.3 17.2 10.7 13.9 1.3 17.2 10.3 133 7 132 165 4.5 0 4.8 4.5 12/07/2005 01:40:00 12.7 1.2 16.4 9.1 12.8 1.2 16.8 9.5 12.4 1.5 16.8 8.4 130 6 128 165 4.6 0 4.8 4.5 12/07/2005 01:50:00 11.6 1.3 14.5 7.6 11.7 1.3 14.9 7.6 11.3 1.4 15.3 6.8 131 8 122 165 4.6 0 4.8 4.5 12/07/2005 02:00:00 11.2 1.2 14.1 7.6 11.4 1.2 14.1 8 11.1 1.2 13.7 8 125 7 129 165 4.7 0 4.8 4.5 12/07/2005 02:10:00 10.8 1.1 14.1 7.6 11 1.1 14.1 7.2 10.7 1.2 13.7 7.6 126 8 135 165 4.7 0 4.8 4.8 12/07/2005 02:20:00 10.6 1 13.7 8.4 10.8 1 13.7 8.4 10.5 1.1 13.7 7.2 128 9 125 165 4.8 0 5 4.8 12/07/2005 02:30:00 10.6 1.2 14.5 8 10.8 1.2 14.5 8 10.5 1.1 14.5 7.6 130 9 144 165 4.8 0 5 4.8 12/07/2005 02:40:00 10.2 1.3 15.3 7.2 10.4 1.3 15.3 7.2 10 1.2 14.1 6.8 125 8 132 165 4.9 0 5 4.5 12/07/2005 02:50:00 11.1 1.8 16.8 6.8 11.3 1.8 16.4 7.2 11.1 1.9 16.8 6.8 126 9 132 165 4.9 0 5 4.8 12/07/2005 03:00:00 11.1 1.4 14.9 7.6 11.2 1.4 15.3 8 11 1.3 15.3 8 136 9 141 165 4.9 0 5.5 5 12/07/2005 03:10:00 11.2 1.8 17.6 6.5 11.2 1.8 17.6 6.8 11 2 16.8 6.5 138 11 133 165 4.9 0 5 5 12/07/2005 03:20:00 13.4 1.6 17.9 9.5 13.4 1.7 17.6 9.1 13.1 1.7 18.3 9.5 141 9 143 165 4.9 0 5 4.8 12/07/2005 03:30:00 13.5 1.4 17.6 10.7 13.5 1.3 17.6 10.7 13.2 1.5 17.9 9.5 144 7 140 165 4.9 0 5 4.8 12/07/2005 03:40:00 13.9 1.3 17.6 8.8 13.9 1.3 17.2 9.5 13.7 1.6 16.8 9.1 141 8 147 165 4.9 0 5 4.8 12/07/2005 03:50:00 13.7 1.5 17.9 9.9 13.7 1.5 17.2 9.9 13.6 1.5 16.8 9.5 143 6 154 165 5 0 5 5 12/07/2005 04:00:00 13.2 1.6 17.6 9.5 13.2 1.6 17.2 9.9 13 1.5 17.2 8.4 144 7 139 165 5.1 0 5 5 12/07/2005 04:10:00 13.2 1 16.1 10.7 13.2 1 16.1 10.3 13.1 1 16.1 10.7 147 7 141 165 5.1 0 5.2 5 12/07/2005 04:20:00 13.1 0.7 14.9 11.5 13 0.7 15.3 11.1 13 0.7 14.9 11.1 149 4 151 165 5.1 0 5.2 5 12/07/2005 04:30:00 12.6 1.2 15.3 9.1 12.6 1.2 15.3 9.5 12.3 1.3 15.3 8.8 145 5 143 165 5.2 0 5.5 5.2 12/07/2005 04:40:00 11.8 1.2 14.9 7.6 11.8 1.1 14.5 8 11.6 1.2 15.3 8.4 146 6 157 165 5.2 0 5.5 5.2 12/07/2005 04:50:00 12.9 1.3 16.1 9.9 12.9 1.2 15.6 9.9 12.6 1.3 16.1 9.9 148 6 150 165 5.4 0 5.5 5.2 12/07/2005 05:00:00 12.8 1.1 16.4 9.9 12.8 1.1 16.1 9.9 12.5 1.2 16.1 9.1 146 6 148 165 5.4 0 5.5 5.5 12/07/2005 05:10:00 13.3 0.9 15.6 11.1 13.3 0.8 15.3 11.1 13.2 0.9 15.3 10.7 148 5 150 165 5.5 0 5.7 5.5 12/07/2005 05:20:00 14.1 0.9 16.1 11.5 14 0.8 16.1 11.5 14 1.1 16.4 10.7 148 4 147 165 5.6 0 5.7 5.5 12/07/2005 05:30:00 14.1 1.1 16.4 10.3 14.1 1.1 16.4 10.7 13.9 1.1 16.8 9.9 150 4 152 165 5.6 0 5.7 5.5 12/07/2005 05:40:00 13.7 0.9 16.1 11.1 13.6 0.9 16.4 11.1 13.5 1 16.1 10.7 150 5 147 165 5.6 0 5.7 5.5 12/07/2005 05:50:00 13.7 0.8 15.3 11.5 13.7 0.8 15.6 11.5 13.5 0.9 15.3 11.5 148 4 146 165 5.6 0 5.7 5.5 12/07/2005 06:00:00 13.7 0.7 15.6 11.5 13.7 0.7 15.3 11.1 13.6 0.7 15.6 11.8 147 3 150 165 5.6 0 5.7 5.5 12/07/2005 06:10:00 13.6 0.8 15.6 11.5 13.6 0.8 15.6 11.8 13.5 0.8 15.6 11.5 149 4 154 165 5.7 0 5.7 5.5 12/07/2005 06:20:00 13.3 0.8 16.1 11.1 13.3 0.8 16.1 11.1 13.1 0.8 15.6 10.7 146 4 151 165 5.7 0 6 5.7 12/07/2005 06:30:00 12.5 0.8 14.5 10.3 12.5 0.8 14.9 9.9 12.3 0.7 14.1 10.3 145 3 145 165 5.7 0 6 5.5 12/07/2005 06:40:00 12.8 0.7 15.3 11.1 12.9 0.7 14.9 11.1 12.6 0.7 14.5 10.3 145 4 145 165 5.7 0 6 5.7 12/07/2005 06:50:00 13.8 1 16.4 11.8 13.8 1 16.4 11.8 13.6 1 16.4 11.1 148 4 151 165 5.8 0 6 5.7 12/07/2005 07:00:00 13 0.9 15.3 10.7 13.1 0.8 14.9 10.7 12.9 0.9 14.9 9.5 149 4 157 165 5.8 0 6 5.7 12/07/2005 07:10:00 11.6 0.8 14.1 9.5 11.6 0.8 14.1 9.1 11.3 0.8 13.7 9.1 145 4 150 165 5.7 0 6 5.7 12/07/2005 07:20:00 11.8 0.6 13.3 9.9 11.9 0.7 13.3 9.5 11.5 0.9 13.7 8.4 143 5 148 165 5.7 0 6 5.7 12/07/2005 07:30:00 12.9 0.8 14.9 10.7 13 0.8 14.9 10.7 12.7 1 14.9 9.9 143 4 145 165 5.7 0 6 5.7 12/07/2005 07:40:00 13.1 0.8 15.3 11.1 13.1 0.8 14.9 11.5 12.9 0.8 15.3 10.7 147 3 145 165 5.7 0 5.7 5.7 12/07/2005 07:50:00 13.5 0.7 15.3 11.5 13.5 0.7 15.6 11.5 13.5 0.7 15.3 11.1 147 4 147 165 5.7 0 5.7 5.7 12/07/2005 08:00:00 13.5 0.8 15.6 11.5 13.4 0.8 15.6 11.8 13.5 0.7 15.3 11.5 152 3 153 165 5.7 0 5.7 5.7 12/07/2005 08:10:00 11.7 0.8 13.7 9.5 11.7 0.7 13.7 9.5 11.6 0.7 13.3 9.5 148 3 151 165 5.7 0 5.7 5.7 12/07/2005 08:20:00 10.6 0.6 12.2 9.1 10.6 0.6 11.8 9.1 10.7 0.7 12.6 9.1 147 4 154 165 5.7 0 6 5.7 12/07/2005 08:30:00 11.7 0.7 13.3 9.9 11.6 0.7 13.3 9.5 11.4 0.7 13.3 9.9 153 3 156 165 5.7 0 5.7 5.7 12/07/2005 08:40:00 11.2 0.7 13.3 9.5 11.2 0.6 13 9.5 11.2 0.6 13 9.5 149 4 148 165 5.7 0 5.7 5.7 12/07/2005 08:50:00 12.4 1.1 14.5 9.1 12.4 1.1 14.9 9.5 12.4 1.1 14.9 9.5 146 4 148 165 5.7 0 6 5.7 12/07/2005 09:00:00 14.1 1 16.1 11.1 14.1 1 16.1 11.1 14.1 1.1 16.1 11.5 146 3 150 165 5.7 0 6 5.7 12/07/2005 09:10:00 14.7 0.8 16.4 11.8 14.7 0.8 16.4 12.2 14.6 0.8 16.4 12.2 150 3 150 165 5.7 0 5.7 5.7 12/07/2005 09:20:00 14.3 0.8 16.4 12.2 14.2 0.8 16.4 12.2 14.2 0.9 16.4 11.1 153 2 158 165 5.7 0 5.7 5.7 12/07/2005 09:30:00 12.8 1 14.9 10.3 12.7 1 15.3 10.3 12.6 1 14.9 10.3 156 3 151 165 5.7 0 5.7 5.7 12/07/2005 09:40:00 11.5 0.5 13 9.9 11.4 0.5 12.6 9.5 11.6 0.5 12.6 10.3 153 3 160 165 5.8 0 6 5.7 12/07/2005 09:50:00 12 0.6 13.3 9.9 12 0.6 13.3 10.3 11.8 0.7 13.3 9.5 148 3 148 165 5.8 0 6 5.7 12/07/2005 10:00:00 14.2 1.5 16.8 11.1 14.1 1.5 16.4 11.5 13.8 1.5 16.4 11.1 150 2 151 165 5.6 0 5.7 5.5 12/07/2005 10:10:00 14.7 0.6 16.1 13 14.7 0.6 16.1 13 14.5 0.8 16.1 12.2 154 2 153 165 5.5 0 5.7 5.5 12/07/2005 10:20:00 13.6 0.8 15.6 11.1 13.6 0.8 15.6 11.5 13.5 0.9 16.1 11.1 155 3 154 165 5.7 0.1 6 5.5 12/07/2005 10:30:00 12.3 1.7 15.3 9.1 12.1 1.6 14.9 9.1 12.4 1.7 15.6 8.8 156 3 158 165 5.9 0 6 5.7 12/07/2005 10:40:00 8.7 0.6 10.3 7.2 8.7 0.6 10.3 7.2 8.5 0.7 10.3 6.5 155 3 155 165 5.7 0 6 5.7 12/07/2005 10:50:00 8.4 0.9 11.5 5.7 8.3 0.9 11.5 5.3 8.2 0.9 11.1 5.7 156 8 162 165 5.9 0 6.2 5.7 12/07/2005 11:00:00 9.6 1.2 12.6 7.2 9.6 1.1 12.6 7.2 9.3 1.2 13 6.8 157 6 165 165 6.1 0 6.7 6 12/07/2005 11:10:00 12.7 1 14.9 9.9 12.6 1 15.3 9.5 12.5 1.3 16.1 8.4 156 7 158 165 6.1 0 6.2 5.7 12/07/2005 11:20:00 11.8 1.1 14.5 8.4 11.7 1 14.1 9.1 11.7 1 14.1 8.8 161 7 165 165 6.2 0 6.2 6 12/07/2005 11:30:00 11.8 0.9 14.5 9.1 11.6 0.9 13.7 9.5 11.8 0.9 14.1 9.1 163 8 165 165 6.1 0 6.2 6 12/07/2005 11:40:00 11.9 0.9 14.5 9.5 11.8 0.8 14.1 9.5 11.8 0.9 14.1 8.8 161 7 166 165 6.2 0 6.2 6 12/07/2005 11:50:00 12.3 1.3 15.6 9.1 12.1 1.2 15.3 9.5 12.2 1.3 15.3 9.1 160 7 163 165 6.2 0 6.2 6 12/07/2005 12:00:00 14.5 1.1 17.2 11.8 14.2 1 16.4 11.8 14.4 0.9 16.8 11.8 166 15 165 165 6.2 0 6.2 6 12/07/2005 12:10:00 15.3 1.3 19.5 12.2 14.9 1.3 19.1 11.8 15.1 1.2 19.1 11.8 168 10 165 165 6.2 0 6.2 6 12/07/2005 12:20:00 14.7 1.3 17.9 11.1 14.5 1.3 17.9 10.7 14.5 1.1 18.7 11.5 164 11 164 165 6.2 0 6.2 6 12/07/2005 12:30:00 14.3 1.3 17.9 10.7 14.1 1.2 17.6 10.3 14.1 1.3 17.6 10.7 163 15 164 165 6.2 0 6.2 6 12/07/2005 12:40:00 14.7 1 17.6 11.5 14.6 1 17.2 11.8 14.6 1 16.8 11.8 168 17 164 165 6.2 0 6.2 6 12/07/2005 12:50:00 13.7 1.2 16.8 9.9 13.4 1.2 16.4 9.9 13.5 1.2 16.1 10.7 168 12 165 165 6.2 0 6.2 6 12/07/2005 13:00:00 13.9 1.1 16.8 10.7 13.6 1 16.4 10.3 13.7 1.2 16.4 11.1 167 12 165 165 6.1 0 6.2 6 12/07/2005 13:10:00 16 1.3 18.7 11.8 15.6 1.3 18.7 11.5 15.9 1.3 18.3 12.2 167 8 178 165 6.2 0 6.2 6 12/07/2005 13:20:00 12.4 1.1 14.5 8.4 12.2 1.1 14.5 7.6 12.3 1.2 14.5 8.4 166 10 166 165 6.2 0 6.2 6.2 12/07/2005 13:30:00 11.9 1.1 14.9 8.8 11.7 1.1 14.5 8.8 11.8 1.1 15.3 9.1 163 10 165 165 6.3 0 6.2 6.2 12/07/2005 13:40:00 13.8 1.1 16.1 9.9 13.5 1.1 15.6 9.5 13.6 1.3 16.4 9.1 165 12 165 165 6.3 0 6.2 6.2 12/07/2005 13:50:00 14.3 0.8 16.1 12.2 13.9 0.8 15.6 11.8 14 0.9 15.6 11.5 168 11 165 165 6.2 0 6.2 6.2 12/07/2005 14:00:00 14.3 0.9 16.1 11.8 13.9 0.8 16.1 11.5 14 0.8 16.4 11.8 167 12 177 165 6.2 0 6.2 5.7 12/07/2005 14:10:00 13.4 1 15.6 11.1 13 1 15.3 10.7 13.2 1 15.6 10.7 171 6 171 165 6.1 0 6.2 6 12/07/2005 14:20:00 12.9 1.1 14.9 9.1 12.4 1 14.5 9.1 12.5 0.9 14.5 10.3 172 12 171 165 6.1 0 6.5 6 12/07/2005 14:30:00 12.9 1.5 16.4 9.5 12.5 1.3 15.6 9.5 12.8 1.3 15.6 9.5 171 7 172 165 6.4 0 6.5 6.2 12/07/2005 14:40:00 15 1.3 17.6 10.7 14.6 1.3 17.2 10.7 14.8 1.3 17.6 11.1 169 11 171 165 6.3 0 6.5 6.2 12/07/2005 14:50:00 17.1 1 19.5 14.5 16.8 1 19.1 14.1 16.8 1.1 19.5 13 167 13 162 165 6.2 0 6.5 6 12/07/2005 15:00:00 17 1.7 20.2 12.6 16.6 1.7 19.5 12.6 16.7 1.6 20.2 13 168 11 168 165 6.2 0 6.2 6 12/07/2005 15:10:00 17.7 1.3 21.4 14.1 17.4 1.2 21 14.1 17.4 1.3 21 13.3 167 13 166 165 6.2 0 6.2 6 12/07/2005 15:20:00 17.5 1.3 20.2 14.1 17.3 1.3 19.9 14.1 17.2 1.3 20.2 13.7 168 22 170 165 6.2 0 6.2 6 12/07/2005 15:30:00 16.9 1.3 19.5 12.6 16.5 1.3 19.1 12.6 16.7 1.3 19.9 12.2 169 11 162 165 6.3 0 6.5 6.2 12/07/2005 15:40:00 13.7 1 16.4 11.1 13.2 1 16.1 10.7 13.6 1 16.1 9.5 173 5 177 165 6.4 0 6.7 6.2 12/07/2005 15:50:00 14.7 1.3 17.6 10.7 14.3 1.3 17.2 10.7 14.7 1.3 17.6 11.1 175 5 175 165 6.5 0 6.7 6.2 12/07/2005 16:00:00 15.6 1.9 21.8 11.8 15.2 1.8 21 11.5 15.4 1.9 20.6 11.5 174 5 171 165 6.6 0 6.7 6.5 12/07/2005 16:10:00 16.1 1 18.7 12.6 15.6 0.9 18.3 13 16.1 1 18.3 13.3 172 5 185 165 6.5 0 6.7 6.2 12/07/2005 16:20:00 14.6 1.1 17.2 11.1 14.1 1.1 16.4 10.7 14.7 1 16.8 11.8 173 8 166 165 6.4 0 6.7 6.2 12/07/2005 16:30:00 15.2 1.3 19.1 11.5 14.7 1.3 18.7 11.1 15.4 1.3 19.1 11.8 172 7 176 165 6.4 0 6.7 6.2 12/07/2005 16:40:00 15.2 1.3 17.9 11.5 14.7 1.3 17.6 11.5 15.1 1.3 17.9 11.5 170 4 160 165 6.3 0 6.5 6.2 12/07/2005 16:50:00 15.8 1.5 19.9 12.6 15.3 1.4 19.1 12.6 15.8 1.5 20.2 12.6 170 10 168 165 6.3 0 6.2 6.2 12/07/2005 17:00:00 14.9 1.1 17.6 11.5 14.5 1.1 17.2 11.1 14.8 1.2 17.6 11.5 172 7 176 165 6.2 0 6.2 6 12/07/2005 17:10:00 15.9 1.1 19.1 12.6 15.4 1.1 18.3 12.2 15.8 1.2 18.3 11.8 172 6 171 165 6.2 0 6.2 6 12/07/2005 17:20:00 17.1 1.1 19.5 14.1 16.6 1 19.1 13.3 16.9 1 19.1 13.3 173 6 173 165 6.2 0 6.2 6 12/07/2005 17:30:00 17 0.9 19.5 14.1 16.6 0.9 19.1 14.1 17 1 19.1 13 172 4 174 165 6.2 0 6.2 6 12/07/2005 17:40:00 17.5 1.2 21 12.6 17 1.2 20.6 12.6 17.4 1.2 20.6 13 171 11 172 165 6.1 0 6.2 6 12/07/2005 17:50:00 16.1 1.3 19.1 12.2 15.6 1.2 18.3 11.8 16 1.2 18.7 11.8 171 5 173 165 6.1 0 6.2 6 12/07/2005 18:00:00 15.9 1 18.7 12.6 15.5 1 18.3 12.6 15.9 1 18.3 13 170 4 165 165 6 0 6.2 5.7 12/07/2005 18:10:00 16.2 0.9 18.3 12.2 15.8 0.9 17.6 12.6 16.1 1 18.3 12.6 172 10 173 165 5.9 0 6 5.7 12/07/2005 18:20:00 16.2 1.3 19.5 13.7 15.8 1.3 19.1 13 16.2 1.3 19.5 13.3 170 7 166 165 5.9 0 6 5.7 12/07/2005 18:30:00 16.2 1.1 19.1 12.6 15.8 1.1 18.7 12.2 16.1 1.2 19.1 13 170 4 170 165 5.8 0 6 5.7 12/07/2005 18:40:00 15.6 1.7 18.7 11.5 15.1 1.6 18.3 11.5 15.5 1.6 18.7 12.2 170 4 163 165 5.7 0 6 5.7 12/07/2005 18:50:00 13.7 0.9 16.1 11.8 13.2 0.9 15.6 11.5 13.5 0.8 16.1 11.5 172 7 172 165 5.7 0 5.7 5.5 12/07/2005 19:00:00 12.8 1 14.9 9.5 12.4 1.1 14.5 9.1 12.8 1 14.9 9.9 175 6 174 165 5.6 0 5.7 5.5 12/07/2005 19:10:00 12.4 1.1 14.9 9.1 12 1 14.9 8.8 12.2 1 14.5 9.5 175 6 172 165 5.5 0 5.7 5.5 12/07/2005 19:20:00 12.1 1.2 14.9 9.5 11.8 1.1 14.5 9.1 12.2 1.1 14.9 9.5 177 6 167 165 5.5 0 5.7 5.5 12/07/2005 19:30:00 13 1.3 16.1 9.5 12.9 1.3 15.6 9.5 13.1 1.2 16.1 9.5 184 6 190 165 5.4 0 5.7 5.5 12/07/2005 19:40:00 15.5 1.3 18.7 11.1 15.5 1.4 18.3 11.5 15.5 1.5 19.1 11.8 188 7 191 165 5.3 0.1 5.5 5.2 12/07/2005 19:50:00 15.9 1.5 19.1 11.1 16 1.5 19.1 11.5 15.9 1.6 20.2 11.5 190 6 189 165 5.2 0 5.2 5 12/07/2005 20:00:00 14.8 1.1 17.6 11.5 14.9 1.2 17.2 11.8 15 1.3 18.3 11.5 196 5 190 165 5.2 0 5.5 5.2 12/07/2005 20:10:00 15.1 1.3 19.1 11.1 15.3 1.4 19.1 11.5 15.1 1.5 19.9 11.5 194 5 191 165 5.3 0 5.5 5.2 12/07/2005 20:20:00 15.2 1.3 19.1 11.5 15.3 1.3 19.1 11.5 15.4 1.5 19.5 10.7 192 5 195 165 5.4 0 5.5 5.2 12/07/2005 20:30:00 14 1 16.1 10.7 14.1 1 16.1 11.1 14.2 1.3 16.8 10.7 192 5 193 165 5.3 0 5.5 5.2 12/07/2005 20:40:00 13.1 1.2 16.1 9.5 13.1 1.2 16.1 9.1 13.4 1.3 16.1 10.3 192 6 191 165 5.4 0 5.5 5.2 12/07/2005 20:50:00 13.3 1.3 16.4 9.9 13.3 1.3 16.1 9.9 13.3 1.3 16.8 10.3 187 7 184 165 5.4 0 5.7 5.2 12/07/2005 21:00:00 13.6 1.2 17.6 10.7 13.3 1.1 16.8 10.7 13.7 1.2 16.8 11.1 182 8 181 165 5.5 0 5.7 5.5 12/07/2005 21:10:00 13.3 1.7 18.3 8.4 13.2 1.6 17.6 8.8 13.3 1.7 18.3 8.8 183 8 186 165 5.6 0 5.7 5.5 12/07/2005 21:20:00 11.5 1.3 14.5 8.8 11.4 1.2 14.1 8.4 11.5 1.2 14.9 8.4 184 8 184 165 5.6 0 5.7 5.5 12/07/2005 21:30:00 10.9 1.5 14.9 6.8 10.8 1.5 14.9 6.8 11.1 1.5 14.9 7.6 184 8 195 165 5.7 0 5.7 5.5 12/07/2005 21:40:00 12.3 1.5 16.1 8 12.1 1.5 16.1 8 12.4 1.5 16.1 9.1 182 10 180 165 5.7 0 5.7 5.5 12/07/2005 21:50:00 13.6 1.6 18.7 10.3 13.4 1.6 18.7 9.9 13.8 1.6 19.9 10.7 183 7 191 165 5.7 0 6 5.5 12/07/2005 22:00:00 13.7 1.5 18.3 9.9 13.5 1.4 17.2 9.9 13.6 1.5 18.3 10.3 179 7 179 165 5.6 0 5.7 5.5 12/07/2005 22:10:00 11.6 1.7 16.4 7.6 11.5 1.7 16.4 7.6 11.4 1.7 15.6 7.6 184 11 193 165 5.5 0 5.7 5.2 12/07/2005 22:20:00 12 1.8 16.4 6.8 12 1.8 16.4 7.2 12 2.1 17.6 7.6 187 10 183 165 5.7 0 5.7 5.7 12/07/2005 22:30:00 11.3 1.5 15.3 7.2 11.2 1.5 15.3 6.8 11.4 1.6 15.6 6.1 185 9 190 165 5.6 0 5.7 5.5 12/07/2005 22:40:00 10.4 2 15.6 6.5 10.5 2 15.3 6.5 10.7 2.1 16.1 6.5 194 8 178 165 5.7 0.1 5.7 5.5 12/07/2005 22:50:00 9.6 1.1 12.6 7.2 9.6 1.1 12.6 7.2 9.7 1.2 12.6 6.5 193 9 197 165 5.6 0 5.7 5.5 12/07/2005 23:00:00 9.7 1.2 13 5.7 9.7 1.2 13 6.5 9.6 1.2 12.6 6.1 189 9 196 165 5.6 0 5.7 5.5 12/07/2005 23:10:00 9.7 1.3 14.5 6.8 9.6 1.3 13.7 6.5 9.7 1.3 14.1 7.2 188 10 179 165 5.5 0 5.7 5.5 12/07/2005 23:20:00 8.5 1.1 11.5 5.3 8.5 1.1 11.1 5.3 8.6 1.1 11.5 5.3 189 10 189 165 5.5 0 5.7 5.5 12/07/2005 23:30:00 9.9 1.3 13.7 6.8 9.8 1.3 13.7 7.2 9.9 1.3 13.3 6.8 189 8 188 165 5.4 0 5.5 5.2 12/07/2005 23:40:00 9.8 1.1 12.2 6.8 9.8 1.1 12.2 6.8 10 1.1 12.6 7.6 188 6 189 165 5.3 0 5.5 5.2 12/07/2005 23:50:00 10.2 1.1 13 7.6 10.3 1.1 13.3 7.6 10.4 1.1 13.3 8 194 6 203 165 5.3 0 5.5 5.2 12/08/2005 00:00:00 10.5 1.4 14.5 7.6 10.5 1.3 14.1 8 10.6 1.3 14.5 7.2 192 6 193 165 5.2 0 5.5 5.2 12/08/2005 00:10:00 11.3 1.4 14.9 8 11.3 1.4 14.5 7.6 11.2 1.3 14.9 7.6 190 7 185 165 5.3 0 5.5 5.2 12/08/2005 00:20:00 11 1.2 13.7 7.6 11 1.1 13.3 7.6 11 1.2 14.9 8 190 6 189 165 5.2 0 5.5 5.2 12/08/2005 00:30:00 10 1 12.6 7.6 10 1 12.2 7.6 10.1 1 12.6 7.2 190 6 197 165 5.2 0 5.5 5.2 12/08/2005 00:40:00 8.4 1 11.1 4.9 8.5 1 11.1 4.9 8.6 1.1 11.5 5.7 198 8 190 165 5.4 0 5.5 5.2 12/08/2005 00:50:00 8.4 1.1 11.1 5.7 8.5 1.1 11.1 5.7 8.2 1.2 11.5 5.7 202 7 196 165 5.3 0 5.7 5.2 12/08/2005 01:00:00 9.7 1.5 14.1 6.1 9.8 1.6 14.1 5.7 9.6 1.7 14.1 6.5 204 7 204 165 5.4 0 5.5 5.2 12/08/2005 01:10:00 10.2 1.5 14.1 6.5 10.3 1.5 14.1 6.5 10 1.5 14.9 6.1 205 7 202 165 5.4 0 5.5 5.2 12/08/2005 01:20:00 8.9 1.4 12.2 5.3 9 1.4 12.6 5.7 8.8 1.4 12.2 5.3 210 7 217 165 5.6 0 5.7 5.5 12/08/2005 01:30:00 8.2 1.3 11.1 4.9 8.3 1.3 11.1 4.9 8 1.2 11.1 4.2 213 10 211 165 5.7 0 5.7 5.5 12/08/2005 01:40:00 7.5 0.9 9.5 5.3 7.6 0.9 9.9 5.3 7.5 1 9.9 4.9 206 7 209 165 5.6 0 5.7 5.5 12/08/2005 01:50:00 7.6 1.2 11.1 4.6 7.7 1.2 11.5 4.6 7.4 1.2 11.1 4.2 211 10 217 165 5.7 0 5.7 5.5 12/08/2005 02:00:00 9.6 2.2 14.1 4.6 9.8 2.2 14.5 4.6 9.4 2.2 14.9 5.3 218 12 230 165 5.7 0 6 5.5 12/08/2005 02:10:00 10.1 1.2 13.3 6.8 10.2 1.3 13.7 6.8 9.7 1.5 13.7 5.3 215 8 226 165 5.7 0 5.7 5.5 12/08/2005 02:20:00 10.4 2.1 15.3 5.3 10.6 2.1 15.6 5.3 10.2 2.2 15.6 5.7 212 12 222 165 5.8 0.1 6 5.7 12/08/2005 02:30:00 8.6 1.2 11.8 5.3 8.7 1.2 12.2 5.7 8.5 1.3 11.8 4.9 206 8 201 165 5.7 0 5.7 5.5 12/08/2005 02:40:00 8.6 1 10.7 6.1 8.7 1 10.7 6.1 8.6 1.1 11.5 6.1 201 7 207 165 5.6 0 5.7 5.5 12/08/2005 02:50:00 8.1 1.1 10.7 4.9 8.1 1.1 10.3 4.9 8.1 1.2 11.1 4.9 193 7 193 165 5.4 0 5.7 5.2 12/08/2005 03:00:00 9.2 1.3 12.6 6.1 9.1 1.3 12.6 6.1 9.2 1.5 13 5.7 190 7 197 165 5.2 0 5.5 5.2 12/08/2005 03:10:00 9.4 1.2 13.3 6.8 9.3 1.2 13.3 6.8 9.4 1.4 13.7 6.5 189 10 193 165 5.3 0 5.7 5.2 12/08/2005 03:20:00 9.6 1.2 12.6 6.8 9.6 1.2 12.6 6.5 9.7 1.1 13 6.8 193 6 183 165 5.6 0 5.7 5.5 12/08/2005 03:30:00 11.7 1.5 16.4 7.6 11.7 1.5 15.6 8 11.7 1.6 16.1 6.8 192 9 194 165 5.7 0.1 6 5.5 12/08/2005 03:40:00 10.6 1.5 14.9 6.5 10.6 1.5 14.5 6.5 10.6 1.5 14.9 6.8 190 8 192 165 5.7 0 5.7 5.5 12/08/2005 03:50:00 9.4 1.1 11.8 6.8 9.4 1.1 11.8 7.2 9.5 1.1 11.8 6.5 193 7 191 165 5.7 0 5.7 5.5 12/08/2005 04:00:00 7.7 0.8 9.9 5.3 7.7 0.8 9.9 5.3 7.5 0.8 9.5 4.9 195 8 198 165 5.6 0 5.7 5.5 12/08/2005 04:10:00 8 1.1 11.1 5.7 7.9 1.1 11.1 5.3 8 1.1 10.7 5.7 185 7 183 165 5.6 0 5.7 5.5 12/08/2005 04:20:00 9.8 1.3 13 6.1 9.8 1.3 13 6.1 9.9 1.3 13.3 6.5 186 7 196 165 5.7 0 5.7 5.5 12/08/2005 04:30:00 10 1.1 12.2 6.5 10 1.1 12.6 6.5 10.2 1.1 12.6 6.8 191 6 206 165 5.7 0 5.7 5.5 12/08/2005 04:40:00 8.7 1.1 11.1 6.1 8.7 1 10.7 6.1 8.8 1.1 11.8 6.1 193 8 191 165 5.7 0 5.7 5.5 12/08/2005 04:50:00 7.3 1.2 10.3 4.6 7.2 1.2 10.3 4.6 7.3 1.2 11.1 4.2 189 9 190 165 5.6 0 5.7 5.5 12/08/2005 05:00:00 7.4 1.5 11.8 4.2 7.4 1.5 11.8 3.8 7.4 1.3 11.5 4.6 196 12 192 165 5.7 0 5.7 5.7 12/08/2005 05:10:00 5.2 2.2 10.7 1.5 5.1 2.2 10.7 1.1 5 2.1 10.7 1.9 196 11 189 165 5.7 0 6 5.7 12/08/2005 05:20:00 3 1.4 6.5 0.4 3 1.4 6.1 0.4 2.9 1.3 5.7 0.4 215 32 233 165 5.5 0 5.7 5.5 12/08/2005 05:30:00 5 1.2 8.8 1.5 5 1.2 8.4 1.9 4.9 1.1 8 1.9 200 18 199 165 5.6 0 5.7 5.5 12/08/2005 05:40:00 7.1 1.5 10.7 2.6 7.1 1.5 10.7 2.6 7.3 1.5 9.9 2.3 197 13 189 165 5.4 0 5.7 5.2 12/08/2005 05:50:00 9.7 1.3 13 6.8 9.8 1.3 13 6.8 9.6 1.2 13 6.5 203 7 206 165 5.2 0 5.5 5 12/08/2005 06:00:00 9 1.3 13 5.7 9.1 1.3 12.6 5.7 8.9 1.3 12.2 4.2 202 8 193 165 5.1 0 5.2 4.8 12/08/2005 06:10:00 10.3 1 13 7.6 10.4 1 13 7.6 10 1.1 13 7.2 198 6 201 165 4.8 0 5 4.8 12/08/2005 06:20:00 11.1 1.3 13.7 6.8 11.1 1.3 13.7 6.5 11.2 1.4 14.5 7.6 194 6 185 165 4.8 0 5 4.8 12/08/2005 06:30:00 10.4 1.1 13 7.6 10.5 1.2 13 7.6 10.6 1.2 13.7 7.6 192 7 202 165 4.7 0 5 4.5 12/08/2005 06:40:00 9.1 1.1 12.2 6.1 9 1.1 11.8 6.5 9.1 0.9 11.8 6.8 185 6 186 165 4.3 0 4.8 4.3 12/08/2005 06:50:00 8.7 0.9 11.5 6.8 8.5 0.8 11.1 6.8 8.8 0.9 11.5 6.5 182 6 178 165 4.2 0 4.5 4.3 12/08/2005 07:00:00 9.6 1 12.2 7.2 9.3 0.9 11.8 7.2 9.6 0.9 11.8 7.2 176 6 175 165 4.4 0 4.5 4.3 12/08/2005 07:10:00 9.6 0.7 11.1 7.2 9.3 0.6 10.7 7.2 9.6 0.7 11.1 7.6 174 5 176 165 4.4 0 4.5 4.3 12/08/2005 07:20:00 9.9 0.9 11.8 8 9.6 0.8 11.5 8 9.9 1 11.8 8 172 5 166 165 4.3 0 4.5 4.3 12/08/2005 07:30:00 10.7 0.5 12.2 8.8 10.3 0.5 11.8 8.8 10.8 0.6 12.2 8.8 169 3 171 165 4.4 0 4.8 4.3 12/08/2005 07:40:00 10.3 0.5 11.5 8.8 9.9 0.5 11.5 8.4 10.3 0.6 11.8 8.8 170 9 171 165 4.4 0 4.8 4.5 12/08/2005 07:50:00 10.1 0.6 11.8 8 9.7 0.6 11.5 8 10.1 0.6 11.5 8.4 172 6 178 165 4.4 0 4.5 4.3 12/08/2005 08:00:00 11.7 0.8 13.7 8.4 11.3 0.8 13.3 8.4 11.7 0.9 13.7 8.8 169 6 166 165 4.4 0 4.5 4.3 12/08/2005 08:10:00 12.7 0.7 14.5 9.9 12.3 0.7 14.1 9.9 12.8 0.9 15.3 10.3 169 14 165 165 4.5 0 4.8 4.5 12/08/2005 08:20:00 12.8 0.7 14.9 11.1 12.4 0.7 14.1 10.7 12.7 0.8 14.5 10.7 170 6 176 165 4.5 0 4.8 4.3 12/08/2005 08:30:00 13.4 0.7 14.9 11.1 12.8 0.7 14.5 10.7 13.3 0.8 15.3 10.7 173 11 176 165 4.7 0 4.8 4.5 12/08/2005 08:40:00 11.3 0.8 13.3 9.1 10.8 0.6 12.6 9.1 11.4 0.8 13.7 9.5 172 10 171 165 4.6 0 4.8 4.5 12/08/2005 08:50:00 10.7 0.9 13.3 8.4 10.3 0.8 12.6 8.4 10.7 0.8 13 8.8 171 6 171 165 4.6 0 4.8 4.5 12/08/2005 09:00:00 12.5 1 15.3 9.1 12 1 14.5 9.1 12.5 1 14.9 9.9 170 10 165 165 4.5 0 4.8 4.5 12/08/2005 09:10:00 13 0.9 14.9 10.3 12.7 0.8 14.5 9.9 13 0.9 15.3 10.3 168 10 165 165 4.6 0 4.8 4.5 12/08/2005 09:20:00 13.6 0.8 15.3 10.3 13.3 0.7 14.9 10.7 13.5 0.8 15.3 11.5 167 6 165 165 4.7 0 4.8 4.5 12/08/2005 09:30:00 13.9 0.9 15.6 11.1 13.5 0.9 15.3 10.7 13.9 0.9 16.1 11.1 169 5 179 165 4.8 0 5 4.8 12/08/2005 09:40:00 13.9 1.2 17.2 11.1 13.7 1.1 16.8 10.7 13.9 1.2 17.2 11.1 169 7 168 165 4.8 0 5 4.8 12/08/2005 09:50:00 14.6 1.2 17.2 11.5 14.1 1.1 16.4 11.1 14.5 1.2 17.2 11.8 172 6 167 165 4.9 0 5 4.8 12/08/2005 10:00:00 12.9 1.2 16.1 9.9 12.6 1.2 16.1 9.5 12.8 1.2 16.4 10.3 176 6 167 165 4.9 0 5 4.8 12/08/2005 10:10:00 10 1.3 13.3 7.2 9.7 1.2 13 7.2 10.1 1.3 13.3 7.2 178 6 181 165 4.8 0 5 4.8 12/08/2005 10:20:00 9.5 1 12.2 7.6 9.2 1 11.8 7.2 9.5 1 12.6 7.2 177 7 175 165 4.8 0 5 4.8 12/08/2005 10:30:00 9.1 1.2 11.8 6.5 9.1 1.1 11.8 6.5 9.3 1.3 11.8 6.5 195 8 194 165 4.9 0 5 4.8 12/08/2005 10:40:00 10 1.4 13.3 6.8 9.9 1.3 13 6.8 10.2 1.2 13 6.8 186 7 192 165 5.1 0 5.2 5 12/08/2005 10:50:00 10.5 1.1 13.7 8 10.3 1.1 13.3 8 10.8 1.1 13.7 7.6 172 9 164 165 5.1 0 5.5 5 12/08/2005 11:00:00 10.3 1 13 7.6 10 1 12.6 7.6 10.5 1.1 13 8 173 7 158 165 4.9 0 5.2 4.8 12/08/2005 11:10:00 8.8 0.9 11.1 6.8 8.5 0.8 10.7 6.8 9 0.7 10.7 7.2 167 13 170 165 5.1 0 5.2 5 12/08/2005 11:20:00 9.6 1 11.8 6.5 9.3 0.9 11.8 6.5 9.7 1 13 7.2 170 10 165 165 5.2 0 5.5 5 12/08/2005 11:30:00 9.1 0.9 11.8 6.1 8.8 0.9 10.7 6.1 9.1 0.9 11.5 6.8 175 10 178 165 5.8 0.1 6 5.5 12/08/2005 11:40:00 9.2 1.2 13 6.8 8.9 1.2 12.6 6.5 9.3 1.3 12.2 6.1 176 9 186 165 5.7 0 5.7 5.5 12/08/2005 11:50:00 9.7 1.2 13 6.5 9.5 1.1 12.6 6.8 9.9 1.3 13.3 6.8 178 10 173 165 5.8 0 6 5.5 12/08/2005 12:00:00 12.6 1.3 15.6 9.5 12.2 1.2 15.3 9.5 12.8 1.2 15.6 9.9 177 6 176 165 5.4 0.2 6 5 12/08/2005 12:10:00 13.1 0.9 14.9 10.7 12.6 0.8 14.5 10.3 13.1 0.9 15.3 10.3 178 6 182 165 5.2 0 5.2 5 12/08/2005 12:20:00 12.2 1 14.5 9.5 11.8 1 14.5 9.1 12.4 1 14.9 9.5 169 10 173 165 5.1 0 5.2 5 12/08/2005 12:30:00 11.2 1.1 14.1 8.4 11 1.1 13.3 8.4 11.5 1.2 13.7 8 169 12 164 165 5.2 0 5.5 5 12/08/2005 12:40:00 11.2 1.1 14.1 8.4 10.9 1 13.3 8.4 11.4 1 13.7 9.1 171 7 182 165 5.3 0 5.5 5.2 12/08/2005 12:50:00 10.8 0.8 13 8.4 10.5 0.8 12.2 8.4 10.9 0.9 12.6 8.4 172 14 180 165 5.2 0 5.5 5.2 12/08/2005 13:00:00 10 1 13 7.6 9.7 1 12.6 7.2 10.2 0.9 12.6 8 175 7 180 165 5.2 0 5.5 5 12/08/2005 13:10:00 8.8 1.3 13 5.7 8.6 1.3 12.6 5.3 9 1.3 13 6.1 175 10 169 165 5.1 0 5.2 5 12/08/2005 13:20:00 8 1 13 5.7 7.8 1 12.6 5.3 8 1 11.1 6.1 180 11 179 165 5.1 0 5.2 5 12/08/2005 13:30:00 7.1 0.6 8.8 5.7 6.8 0.6 8 5.7 7.2 0.6 8.8 5.7 168 11 172 165 5 0 5.2 4.8 12/08/2005 13:40:00 7.3 0.7 9.9 5.7 7 0.7 9.5 5.7 7.2 0.7 9.5 5.7 171 9 181 165 4.9 0 5 4.8 12/08/2005 13:50:00 7.2 0.7 9.1 5.7 6.9 0.7 8.8 5.3 7.3 0.7 9.5 5.7 174 7 178 165 4.9 0 5 4.8 12/08/2005 14:00:00 7.5 0.8 9.5 6.1 7.2 0.7 8.8 5.7 7.5 0.7 9.5 6.1 172 9 179 165 4.9 0 5 4.5 12/08/2005 14:10:00 7.6 0.5 8.8 6.5 7.2 0.5 8.8 6.5 7.6 0.6 9.1 6.5 166 5 164 165 4.8 0.1 5 4.8 12/08/2005 14:20:00 8.7 1.3 11.5 6.5 8.4 1.3 11.1 6.5 8.8 1.3 11.8 6.5 167 11 169 165 4.8 0 5 4.8 12/08/2005 14:30:00 9.4 0.8 11.1 6.5 9 0.8 10.7 6.5 9.5 0.7 11.1 7.6 175 6 171 165 4.9 0 5 4.8 12/08/2005 14:40:00 10.1 0.8 12.6 8 9.7 0.7 11.8 8 10.2 0.8 12.2 8.4 174 6 169 165 4.9 0 5 4.8 12/08/2005 14:50:00 10.8 0.6 12.6 9.1 10.6 0.6 12.2 8.8 11 0.7 12.6 9.1 166 11 169 165 4.9 0 5 4.8 12/08/2005 15:00:00 12.6 1.1 14.9 9.5 12.2 1 14.1 9.5 12.7 1.1 15.3 9.9 168 10 169 165 4.9 0 5 4.8 12/08/2005 15:10:00 13.7 0.9 16.4 11.1 13.2 0.8 16.1 10.7 13.7 0.9 16.8 11.1 172 8 172 165 4.9 0 5 4.8 12/08/2005 15:20:00 13 0.8 15.6 11.1 12.5 0.8 14.9 10.7 13.1 0.8 15.6 10.7 173 4 168 165 4.8 0 5 4.8 12/08/2005 15:30:00 12 0.7 13.7 9.5 11.7 0.6 13.3 9.1 12 0.7 14.1 8.8 173 4 168 165 4.7 0 5 4.8 12/08/2005 15:40:00 11.5 0.9 13.3 8.8 11.2 0.8 13 8.8 11.6 0.9 14.1 8.8 172 9 177 165 4.7 0 4.8 4.8 12/08/2005 15:50:00 13.3 1.2 16.4 9.9 13 1.2 16.1 10.3 13.1 1.3 16.1 9.9 170 6 174 165 4.7 0 4.8 4.5 12/08/2005 16:00:00 14.6 0.9 16.8 11.8 14.2 0.9 16.4 11.8 14.6 1 16.8 11.8 170 6 170 165 4.7 0 4.8 4.5 12/08/2005 16:10:00 14.8 0.8 16.8 12.2 14.4 0.8 16.4 11.8 14.9 0.8 17.6 12.2 167 4 170 165 4.8 0 5 4.8 12/08/2005 16:20:00 14.9 1 18.3 11.8 14.7 0.9 17.9 12.2 14.7 1 17.2 11.8 166 10 164 165 4.8 0 5 4.8 12/08/2005 16:30:00 14.6 1 16.8 11.8 14.4 1 16.4 11.8 14.7 1 17.6 11.8 164 14 164 165 4.9 0 5 4.8 12/08/2005 16:40:00 14.4 0.8 16.8 11.1 14.2 0.7 16.1 11.1 14.3 1 16.1 10.7 166 10 170 165 4.9 0 5 4.8 12/08/2005 16:50:00 12.6 1.1 14.9 8.8 12.4 1 14.9 8.8 12.6 1.1 15.3 9.1 166 9 160 165 4.9 0 5 4.8 12/08/2005 17:00:00 12.8 0.9 14.9 10.3 12.4 0.8 14.5 9.9 12.8 0.8 15.3 9.9 168 6 172 165 4.9 0 5 4.8 12/08/2005 17:10:00 10.5 0.8 13 8.4 10.2 0.9 12.6 7.6 10.6 0.8 12.6 8.4 171 5 176 165 4.8 0 5 4.8 12/08/2005 17:20:00 10.6 1.4 14.1 7.2 10.3 1.3 13.7 7.2 10.4 1.3 14.1 7.2 170 9 168 165 4.8 0 5 4.8 12/08/2005 17:30:00 14 1.7 16.8 9.9 13.8 1.7 16.4 9.5 14.1 1.6 18.3 9.5 167 14 169 165 4.8 0 5 4.8 12/08/2005 17:40:00 16.6 1 19.1 13.7 16.2 0.9 18.7 13.3 16.6 1 19.1 13.7 168 12 170 165 4.7 0 5 4.8 12/08/2005 17:50:00 15.6 1 17.9 12.6 15.3 1 17.9 12.6 15.7 1 18.3 12.6 168 9 174 165 4.7 0 5 4.8 12/08/2005 18:00:00 14.1 1 16.4 11.5 13.8 1 15.6 11.1 14.2 1.2 16.4 11.1 170 5 169 165 4.8 0 5 4.8 12/08/2005 18:10:00 16.1 1.3 19.5 13 15.6 1.3 19.1 12.6 16 1.3 19.1 13 173 5 167 165 4.9 0 5 4.8 12/08/2005 18:20:00 15.1 1.1 18.3 12.2 14.8 1.1 17.9 11.8 15.3 1 17.6 13 169 5 172 165 4.9 0 5 4.8 12/08/2005 18:30:00 16.8 1.4 19.9 13 16.5 1.4 19.5 12.6 16.7 1.4 19.9 13.3 168 17 166 165 4.9 0 5 4.8 12/08/2005 18:40:00 18.1 1.1 21 15.3 17.8 1 21 15.3 18.2 1.2 21.4 14.9 167 11 165 165 5 0 5 5 12/08/2005 18:50:00 16.2 1.4 18.7 12.2 15.8 1.3 18.3 11.5 16.4 1.3 19.5 12.6 171 5 170 165 4.9 0 5 4.8 12/08/2005 19:00:00 12.1 1.1 17.2 9.5 11.9 1.1 16.8 9.5 12.3 1 15.6 9.9 172 6 179 165 4.7 0.1 5 4.5 12/08/2005 19:10:00 15.8 1.7 19.5 11.8 15.4 1.7 18.7 11.8 15.7 1.9 19.5 11.1 170 5 176 165 4.7 0.1 5 4.5 12/08/2005 19:20:00 17.5 0.9 20.2 14.5 17.1 0.9 19.9 14.5 17.6 1 20.2 14.5 170 14 171 165 4.9 0 5 4.8 12/08/2005 19:30:00 18.3 1.4 22.9 14.9 17.8 1.4 22.6 14.9 18.4 1.5 22.1 14.1 169 4 169 165 4.9 0 5 5 12/08/2005 19:40:00 18.1 1.2 20.6 14.1 17.7 1.1 19.9 13.7 17.9 1.3 20.6 14.1 171 5 166 165 4.9 0 5 4.8 12/08/2005 19:50:00 17.4 1 19.5 14.5 16.9 1 19.5 14.1 17.6 1 20.2 14.9 172 4 180 165 4.9 0 5 4.8 12/08/2005 20:00:00 16.8 1.2 19.5 13.7 16.3 1.1 18.7 13.7 16.7 1.3 19.5 12.6 170 6 169 165 4.9 0 5 4.8 12/08/2005 20:10:00 16.8 1.1 19.1 13.3 16.4 1.1 18.7 13.3 16.8 1.2 19.1 13 171 5 165 165 4.9 0 5 4.8 12/08/2005 20:20:00 15.2 1.3 18.3 11.8 14.8 1.3 17.9 11.5 15.3 1.3 19.1 12.2 169 12 165 165 4.9 0 5 4.8 12/08/2005 20:30:00 17.9 1.2 20.6 14.1 17.5 1.2 20.2 13.7 17.8 1.3 21 13.3 167 8 168 165 4.9 0 5 4.8 12/08/2005 20:40:00 17.7 1.3 21 14.1 17.4 1.3 21 14.1 17.6 1.4 21 13.7 167 15 165 165 5 0 5.2 4.8 12/08/2005 20:50:00 18.3 1.3 21.4 15.6 18.1 1.3 21.4 15.3 18.2 1.4 21.4 14.9 167 9 165 165 5.1 0 5.2 5 12/08/2005 21:00:00 19 1.3 22.6 16.1 18.7 1.2 22.1 15.3 18.9 1.3 22.1 15.3 168 9 165 165 5.1 0 5.7 5 12/08/2005 21:10:00 18 1.2 22.1 13.3 17.7 1.2 21.4 13.3 18 1.2 21.4 14.1 169 15 172 165 5 0 5.2 4.8 12/08/2005 21:20:00 18.5 1.3 21.4 14.5 18.2 1.2 21 14.1 18.7 1.2 21.8 15.6 167 11 166 165 5.1 0 5.2 5 12/08/2005 21:30:00 20.2 1.4 23.7 17.2 19.8 1.3 23.7 16.8 20.4 1.5 24.4 16.8 169 13 166 165 5.1 0 5.2 5 12/08/2005 21:40:00 17.6 1.1 20.6 14.5 17.3 1 20.6 14.1 17.6 1.1 20.6 14.5 167 13 170 165 5.1 0 5.2 5 12/08/2005 21:50:00 16.7 1.5 20.2 13.7 16.4 1.5 19.9 13.3 16.8 1.4 20.2 13.3 169 9 167 165 5.1 0 5.2 5 12/08/2005 22:00:00 17.4 1.5 21.8 14.5 16.9 1.5 21 13.7 17.5 1.5 21.4 14.5 170 13 165 165 5.1 0 5.2 5 12/08/2005 22:10:00 19 1.1 21.4 15.6 18.5 1.1 21 15.3 19 1.2 21.8 14.5 169 7 165 165 5.2 0 5.2 5 12/08/2005 22:20:00 18.7 1 21 15.6 18.3 1 20.2 15.3 18.9 1 21.4 16.1 170 10 167 165 5.2 0 5.2 5 12/08/2005 22:30:00 18.7 1 21 15.6 18.4 1 21 15.6 18.8 1.2 21.4 14.9 168 11 165 165 5.2 0 5.5 5 12/08/2005 22:40:00 18.4 0.9 21.4 14.9 18 1 21.4 14.9 18.4 1 21.4 15.3 168 14 165 165 5.2 0 5.5 5.2 12/08/2005 22:50:00 18.6 1.1 22.6 15.6 18.2 1.1 22.1 15.3 18.6 1.2 21 15.3 167 12 165 165 5.2 0 5.5 5.2 12/08/2005 23:00:00 16.7 1.5 19.9 13 16.4 1.4 19.5 12.2 16.6 1.5 19.5 12.6 168 13 165 165 5.2 0 5.5 5 12/08/2005 23:10:00 16.1 1 18.7 13.3 15.7 1 17.9 12.6 15.9 1.1 18.7 13 169 4 173 165 5.2 0 5.5 5.2 12/08/2005 23:20:00 15.4 1 17.6 12.6 15 0.9 17.2 11.8 15.4 1 18.3 12.6 168 9 171 165 5.3 0 5.5 5.2 12/08/2005 23:30:00 14.8 1 17.6 11.8 14.5 0.9 16.8 11.8 14.7 1 17.2 11.8 167 16 164 165 5.4 0 5.7 5.5 12/08/2005 23:40:00 13.6 1 16.1 11.1 13.4 1 15.6 11.1 13.5 1.1 16.4 11.1 167 9 165 165 5.5 0 5.7 5.5 12/08/2005 23:50:00 14.9 1.3 17.9 11.8 14.6 1.2 17.6 11.8 14.9 1.3 18.3 11.8 172 6 180 165 5.6 0 5.7 5.5 12/09/2005 00:00:00 11.4 2.6 17.9 7.6 11.2 2.5 17.6 7.6 11.4 2.6 18.3 7.6 160 12 170 165 5.6 0 5.7 5.5 12/09/2005 00:10:00 8.5 1 10.7 5.3 8.4 1 10.7 5.7 8.5 0.9 10.7 6.5 156 5 164 165 5.4 0 5.5 5.2 12/09/2005 00:20:00 10 1.1 12.6 7.2 9.9 1 12.6 7.2 9.6 1.2 13 6.5 150 3 147 165 5.2 0 5.5 5.2 12/09/2005 00:30:00 12 0.5 13.3 10.3 12 0.5 13.3 10.7 11.9 0.6 13.3 9.9 149 3 153 165 5.2 0 5.5 5 12/09/2005 00:40:00 12.5 0.6 14.1 10.3 12.4 0.6 14.1 10.3 12.4 0.7 14.1 10.3 148 3 153 165 5.2 0 5.5 5.2 12/09/2005 00:50:00 13.1 1.1 15.3 10.7 13 1.1 14.9 10.7 13 1 15.6 10.7 152 4 157 165 5.2 0 5.5 5 12/09/2005 01:00:00 13.8 1 16.1 11.1 13.7 1 16.1 11.1 13.5 1 16.1 10.7 153 3 157 165 5.2 0 5.5 5.2 12/09/2005 01:10:00 14.1 0.8 16.1 11.8 14 0.8 16.1 11.8 14.1 0.8 16.1 11.8 154 3 154 165 5.2 0 5.2 5 12/09/2005 01:20:00 14 0.6 15.3 12.2 13.9 0.6 15.6 11.8 14 0.8 15.6 11.5 155 3 155 165 5.2 0 5.2 5 12/09/2005 01:30:00 13 0.5 14.1 11.5 12.9 0.5 13.7 11.5 12.9 0.6 14.1 11.1 155 2 154 165 5.1 0 5.2 5 12/09/2005 01:40:00 13.8 0.8 15.6 11.8 13.7 0.8 15.3 11.8 13.7 0.9 15.6 11.5 153 3 154 165 5.1 0 5.2 5 12/09/2005 01:50:00 13.8 0.6 14.9 11.8 13.7 0.6 14.9 11.8 13.7 0.8 15.6 11.8 154 3 156 165 5.1 0 5.2 5 12/09/2005 02:00:00 14.2 1 16.4 11.8 14.1 1 16.4 11.8 14 1 16.4 11.8 153 3 152 165 5.1 0 5.2 5 12/09/2005 02:10:00 15.7 0.9 17.9 13.7 15.6 0.9 17.9 13.3 15.6 1 17.9 13 152 3 148 165 5.1 0 5.2 5 12/09/2005 02:20:00 16.6 0.7 18.3 14.5 16.4 0.7 18.7 14.1 16.4 0.8 18.3 13.7 152 3 157 165 5.2 0 5.2 5 12/09/2005 02:30:00 16.2 0.6 17.6 14.5 16.1 0.6 17.6 14.1 16 0.7 17.6 14.1 151 3 158 165 5.2 0 5.2 5 12/09/2005 02:40:00 16.1 0.7 18.3 13.7 15.9 0.7 17.9 13.7 15.9 0.7 17.6 14.1 152 2 156 165 5.2 0 5.2 5.2 12/09/2005 02:50:00 15.5 0.7 17.6 13 15.4 0.7 17.6 13 15.2 0.8 17.2 13 151 3 153 165 5.2 0 5.5 5.2 12/09/2005 03:00:00 14.6 0.8 16.4 11.8 14.6 0.8 16.1 11.8 14.1 1 16.1 10.3 150 3 150 165 5.2 0 5.2 5 12/09/2005 03:10:00 15 0.8 16.8 13 15 0.8 16.8 12.6 14.8 1.1 16.8 11.5 150 3 148 165 5.2 0 5.2 5 12/09/2005 03:20:00 13.8 1 16.1 11.8 13.8 0.9 16.4 11.5 13.3 1.1 15.6 11.1 147 3 150 165 5.1 0 5.2 5 12/09/2005 03:30:00 13.6 0.8 15.6 11.5 13.6 0.8 15.6 11.5 13.1 0.9 15.3 10.3 148 3 151 165 5.1 0 5.2 5 12/09/2005 03:40:00 13.5 0.7 14.9 11.5 13.5 0.7 15.3 11.5 13.1 0.8 15.6 10.7 147 3 147 165 5.1 0 5 5 12/09/2005 03:50:00 13.7 0.8 15.6 11.8 13.6 0.7 16.1 11.8 13.3 0.9 16.4 9.9 149 4 141 165 5.1 0 5 5 12/09/2005 04:00:00 13.5 0.7 14.9 11.1 13.5 0.7 14.9 11.5 13.1 1 15.3 9.9 149 3 150 165 5.1 0 5.2 5 12/09/2005 04:10:00 14 0.8 16.4 11.8 14 0.8 16.4 11.8 13.6 0.9 15.6 11.1 148 4 148 165 5 0 5 5 12/09/2005 04:20:00 14 0.9 16.1 11.8 14 0.9 16.1 11.8 13.7 1 16.4 11.1 148 3 151 165 4.9 0 5 5 12/09/2005 04:30:00 13.8 0.9 16.1 10.7 13.8 0.9 16.1 11.1 13.6 1 16.1 11.5 147 3 147 165 4.9 0 5 4.8 12/09/2005 04:40:00 13.7 0.9 15.3 11.1 13.7 0.9 15.3 11.5 13.4 0.9 15.6 11.1 147 4 154 165 4.9 0 5 5 12/09/2005 04:50:00 14 1.1 17.2 9.5 14 1.1 17.2 9.1 13.7 1.3 16.4 9.5 146 4 148 165 5 0 5 5 12/09/2005 05:00:00 13.5 0.9 15.6 9.9 13.5 0.9 15.6 10.3 13.2 1 16.4 10.7 145 5 150 165 5 0 5 5 12/09/2005 05:10:00 12.6 1.1 15.6 9.5 12.6 1.1 15.6 9.5 12.3 1.2 15.3 8.8 144 5 133 165 4.9 0 5 5 12/09/2005 05:20:00 13.5 1.2 16.1 9.1 13.5 1.2 16.4 8.8 13.3 1.3 16.8 9.1 142 7 144 165 4.9 0 5 4.8 12/09/2005 05:30:00 13.2 1.3 16.4 9.9 13.3 1.3 16.4 9.5 13.1 1.5 16.4 8.8 142 6 147 165 4.9 0 5 4.8 12/09/2005 05:40:00 11.9 1.1 14.9 9.1 12 1.1 15.3 9.1 11.7 1.2 14.9 8.8 142 7 139 165 4.9 0 5 4.8 12/09/2005 05:50:00 10.8 1 13.3 8.4 10.9 1 13.3 8.4 10.5 1.1 13.7 7.6 137 7 141 165 4.9 0 5 4.8 12/09/2005 06:00:00 11.2 1.3 14.5 8 11.4 1.3 14.5 8 11 1.4 14.1 6.8 135 6 128 165 5.1 0 5 5 12/09/2005 06:10:00 10.9 1.1 14.1 8 11.1 1.1 14.1 8.4 10.6 1.2 14.1 8.4 131 8 142 165 5.1 0 5 5 12/09/2005 06:20:00 10.6 1.2 14.1 8 10.8 1.2 14.1 8 10.3 1.2 14.1 7.2 126 7 122 165 5.1 0 5.2 5 12/09/2005 06:30:00 10.9 1.3 13.7 7.2 11.2 1.3 14.1 8 10.7 1.5 13.7 6.8 119 7 126 165 4.8 0.1 5 4.5 12/09/2005 06:40:00 10.7 1.1 13.3 6.8 10.9 1.2 13.7 6.5 10.2 1.3 13.7 6.8 116 7 113 165 4.7 0.1 5 4.5 12/09/2005 06:50:00 8.8 1.1 11.1 5.7 9 1.1 11.5 5.7 8.2 1.3 11.1 4.9 103 7 108 165 4.5 0 4.8 4.3 12/09/2005 07:00:00 9.4 1 13 6.5 9.6 1.1 13 6.5 8.9 1 12.2 5.7 91 6 91 165 4.6 0 4.8 4.5 12/09/2005 07:10:00 10.5 1.3 13.3 6.5 10.8 1.4 13.3 6.5 10.1 1.3 13 6.8 95 8 88 165 4.6 0 4.8 4.5 12/09/2005 07:20:00 10.4 1.3 13.7 6.5 10.6 1.4 13.7 6.1 9.9 1.3 13 6.5 89 7 78 165 4.1 0.1 4.5 4 12/09/2005 07:30:00 9.6 1.7 14.1 6.1 9.9 1.8 14.5 6.5 9.4 1.7 14.5 5.7 87 9 81 165 4.1 0 4.5 3.8 12/09/2005 07:40:00 8.8 1.5 12.6 4.6 9 1.5 13 4.6 8.5 1.3 11.1 5.7 71 10 85 165 4 0 4.3 3.8 12/09/2005 07:50:00 9.9 2 15.6 6.1 10.1 2.1 16.4 6.1 9.5 2 14.9 4.9 73 13 99 165 4 0 4.3 3.8 12/09/2005 08:00:00 9.9 1.5 14.1 6.5 10 1.6 14.5 6.5 9.6 1.2 13 6.5 66 10 69 165 4 0 4.3 3.8 12/09/2005 08:10:00 9.6 1.9 16.4 5.3 9.7 2 16.4 5.3 9.4 1.9 14.1 4.9 64 11 74 165 4 0 4.3 4 12/09/2005 08:20:00 10.1 2.5 16.1 4.9 10.3 2.7 16.8 4.9 9.8 2.5 15.6 4.9 75 9 79 165 3.9 0 4.3 3.8 12/09/2005 08:30:00 8.5 1.5 13 5.3 8.6 1.6 13 5.3 8.1 1.3 12.6 5.3 63 12 52 165 3.8 0 4 3.8 12/09/2005 08:40:00 11.1 2.2 17.2 6.1 11.3 2.3 17.9 6.1 10.7 2.2 17.2 4.9 62 11 64 165 3.8 0 4 3.5 12/09/2005 08:50:00 11.1 2.4 18.7 5.3 11.3 2.5 19.5 5.7 10.6 2.1 17.9 6.5 61 11 42 165 3.5 0 3.5 3.3 12/09/2005 09:00:00 9.2 1.5 15.3 5.7 9.4 1.6 14.9 5.7 8.7 1.6 14.5 5.3 60 11 52 165 3.5 0 3.5 3.5 12/09/2005 09:10:00 10.1 2 15.3 5.7 10.2 2.1 15.6 5.7 9.7 1.8 14.9 5.7 43 13 56 165 3.5 0 3.5 3.3 12/09/2005 09:20:00 10.9 2.1 16.1 6.1 10.9 2.2 16.4 6.1 10.2 2.1 16.8 5.7 38 12 43 165 3.3 0 3.5 3.3 12/09/2005 09:30:00 11.4 1.7 15.6 6.8 11.1 1.8 15.3 5.3 11.2 1.7 15.3 7.2 29 11 40 165 3.2 0 3.3 3 12/09/2005 09:40:00 13.3 2.1 19.5 7.6 13.1 2.1 19.1 7.6 12.8 2.1 18.3 8 30 8 34 165 3 0 3.3 2.8 12/09/2005 09:50:00 14.3 2.2 18.3 8.8 14.1 2.3 18.7 7.6 13.8 2.1 18.3 8.8 25 8 23 165 3 0 3.3 2.8 12/09/2005 10:00:00 14.7 2.1 19.1 9.1 14 2.1 19.1 8 14.2 2.1 19.9 9.5 20 8 12 165 2.8 0 3 2.8 12/09/2005 10:10:00 14.1 1.9 19.1 9.5 12.2 2.5 18.3 6.5 13.6 2 18.7 8.8 14 9 14 165 2.8 0 2.8 2.8 12/09/2005 10:20:00 14.6 1.4 17.9 10.7 13.1 2 16.4 7.6 14.1 1.3 17.2 10.7 13 7 13 165 2.9 0 3 2.8 12/09/2005 10:30:00 14.9 1.3 18.7 10.7 10.4 1.9 16.8 6.8 15 1.5 19.9 11.1 4 7 4 165 2.9 0 3 2.8 12/09/2005 10:40:00 14.1 1.7 18.3 10.7 10.5 2.5 16.4 6.1 14 1.8 19.1 9.9 5 7 6 165 2.9 0 3 2.8 12/09/2005 10:50:00 15.4 1.9 19.5 10.3 11.2 2 17.9 6.8 15.1 1.9 19.1 10.3 357 6 2 165 2.9 0 3.3 2.8 12/09/2005 11:00:00 14.9 1.7 20.2 9.1 11.1 2.2 18.3 7.2 14.6 1.8 19.5 9.9 357 8 4 165 3.3 0.1 3.5 3 12/09/2005 11:10:00 14 1.6 18.7 9.9 9.9 1.8 16.8 6.5 14 1.6 18.3 10.7 358 6 352 165 3.6 0 3.8 3.5 12/09/2005 11:20:00 13 1.9 16.8 6.8 9.5 1.8 15.3 6.1 12.9 1.9 17.6 8 357 9 6 165 3.8 0 4 3.8 12/09/2005 11:30:00 12.4 1.7 16.1 8.8 9.9 2.2 15.6 5.7 12 1.7 16.8 8.4 354 8 356 165 3.8 0 3.8 3.5 12/09/2005 11:40:00 9.2 2.1 15.3 5.3 8.7 1.7 13.7 4.6 8.9 2.1 14.5 5.3 341 10 350 165 3.8 0 4 3.5 12/09/2005 11:50:00 9.2 1.1 13 6.1 9 1.2 12.2 6.1 8.9 1.2 12.2 6.5 338 10 351 165 3.6 0 3.8 3.5 12/09/2005 12:00:00 10.7 1.4 15.3 8 10.7 1.5 14.9 7.6 10.5 1.6 14.5 6.8 334 8 339 165 3.6 0 3.8 3.5 12/09/2005 12:10:00 11 1.3 13.7 7.6 11 1.5 14.1 6.8 10.9 1.3 14.1 7.6 343 6 336 165 3.6 0 3.8 3.5 12/09/2005 12:20:00 10.1 1.5 14.1 6.8 10 1.5 14.5 6.5 9.5 1.3 13.3 6.5 332 9 348 165 3.8 0 3.8 3.5 12/09/2005 12:30:00 10.7 1.6 14.5 5.7 10.6 1.6 14.5 5.7 10.1 1.6 14.1 5.7 329 9 332 165 3.9 0 4 3.8 12/09/2005 12:40:00 11.1 1.5 15.3 7.2 11 1.5 14.9 7.2 10.6 1.5 14.1 7.2 331 9 337 165 4 0 4.3 3.8 12/09/2005 12:50:00 13.2 1.3 16.4 9.9 13 1.5 16.1 7.6 12.7 1.3 16.1 9.1 334 8 337 165 4 0 4.3 3.8 12/09/2005 13:00:00 12.7 1.3 15.6 9.1 12.6 1.3 15.6 8.4 12.5 1.3 15.6 8.8 335 7 327 165 4.1 0 4.3 4.3 12/09/2005 13:10:00 12.2 1.4 15.6 8.4 12.2 1.4 15.6 8.8 11.9 1.4 15.6 8 334 7 334 165 4.1 0 4.3 4.3 12/09/2005 13:20:00 12.4 1.5 15.3 8 12.4 1.5 15.3 8.4 12.2 1.6 15.6 7.6 333 8 334 165 4.3 0 4.5 4.3 12/09/2005 13:30:00 11 1.2 14.5 7.2 10.9 1.1 14.1 7.2 10.5 1.5 14.1 6.8 316 10 317 165 3.8 0.1 4.5 3.5 12/09/2005 13:40:00 12.4 1.2 15.3 8.4 12.3 1.1 14.9 8.4 9.8 1.3 13.3 6.1 304 7 297 165 3.6 0 3.8 3.5 12/09/2005 13:50:00 11.9 1.1 15.6 8.4 11.8 1.1 14.9 8.8 9.9 1.5 13 6.1 306 9 294 165 3.6 0 3.8 3.5 12/09/2005 14:00:00 12.3 1.3 15.6 8.8 12.2 1.2 15.6 8.8 9.8 1.5 14.5 6.8 300 9 307 165 3.6 0 4 3.5 12/09/2005 14:10:00 12 1.1 14.5 8.4 11.9 1.1 14.5 8.4 9.7 1.5 15.3 6.1 297 7 290 165 3.6 0 3.8 3.5 12/09/2005 14:20:00 12 1.3 14.9 8 11.8 1.3 14.5 8.4 9.3 1.3 13.7 6.5 300 7 306 165 3.6 0 3.8 3.5 12/09/2005 14:30:00 12 1.2 14.9 8.8 11.8 1.1 14.9 8.8 9.3 1.4 15.6 6.1 298 7 287 165 3.6 0 3.8 3.5 12/09/2005 14:40:00 11.9 1.3 15.3 8.8 11.9 1.2 14.9 8.4 9.4 1.3 13.7 6.5 301 7 309 165 3.6 0.1 3.8 3.5 12/09/2005 14:50:00 10.9 1.3 13.7 7.6 10.8 1.2 13.7 7.6 9.3 1.3 13 6.5 308 9 298 165 3.8 0 3.8 3.5 12/09/2005 15:00:00 10.2 1.2 13.3 7.2 10.2 1.2 13.3 6.5 8.4 1.3 13.7 5.3 303 9 290 165 3.8 0 4 3.5 12/09/2005 15:10:00 12.4 1.6 16.4 7.2 12.3 1.6 16.4 7.6 9.3 1.3 13.3 5.3 300 6 294 165 3.7 0 4 3.5 12/09/2005 15:20:00 12.6 1.3 15.3 9.1 12.5 1.3 15.3 9.1 9.9 1.3 14.1 6.8 303 6 301 165 3.7 0 3.8 3.5 12/09/2005 15:30:00 12 1.7 15.6 5.3 12 1.6 15.3 4.9 9.7 1.4 13.3 5.3 304 6 305 165 3.8 0 3.8 3.8 12/09/2005 15:40:00 12.4 1.4 16.1 9.5 12.4 1.3 16.1 9.1 9.6 1.5 16.4 6.1 302 6 292 165 3.8 0 3.8 3.8 12/09/2005 15:50:00 12.7 1.4 16.1 8.8 12.7 1.4 16.1 8.4 10.3 1.3 13.7 5.7 304 5 299 165 3.8 0 3.8 3.8 12/09/2005 16:00:00 13 1.3 16.8 8.4 12.9 1.3 16.8 8 10.9 1.2 14.1 6.8 306 4 302 165 3.6 0 3.8 3.5 12/09/2005 16:10:00 12.7 1.3 17.6 9.9 12.7 1.3 17.9 9.9 10 1.2 13.7 6.8 303 4 309 165 3.6 0 3.8 3.5 12/09/2005 16:20:00 13.3 1.4 16.8 8.8 13.4 1.3 16.8 9.1 11.5 1.2 14.1 7.6 306 4 300 165 3.6 0 3.8 3.5 12/09/2005 16:30:00 13.3 1.5 16.8 9.1 13.3 1.4 16.4 9.1 11 1.2 14.1 7.2 306 5 300 165 3.6 0 3.8 3.5 12/09/2005 16:40:00 13 1.5 16.8 9.1 13 1.5 16.8 9.1 10.8 1.3 16.1 6.8 305 5 301 165 3.6 0 3.8 3.5 12/09/2005 16:50:00 13.5 1.2 16.4 10.3 13.4 1.2 16.4 10.3 11.5 1.3 15.3 8 307 5 307 165 3.6 0 3.8 3.5 12/09/2005 17:00:00 13.7 1 16.4 9.9 13.7 1 16.1 9.9 11.9 1.3 15.6 8 308 5 301 165 3.6 0 3.8 3.5 12/09/2005 17:10:00 13.2 1.1 16.4 9.5 13.1 1.1 16.4 9.5 11.4 1.2 14.9 8.4 308 5 306 165 3.6 0 3.8 3.5 12/09/2005 17:20:00 12.6 1 14.9 9.9 12.5 0.9 14.9 9.9 11.2 1.2 14.9 7.6 309 6 300 165 3.6 0 3.8 3.5 12/09/2005 17:30:00 10.9 1.3 15.3 8.4 10.9 1.3 15.3 8 9.5 1.5 13.7 6.5 309 6 310 165 3.6 0 3.8 3.5 12/09/2005 17:40:00 9.7 1.2 13 6.5 9.6 1.2 13 6.1 7.9 1.5 12.6 4.6 305 7 306 165 3.6 0 3.8 3.5 12/09/2005 17:50:00 8.5 1 11.5 5.7 8.5 0.9 10.7 5.7 7.4 0.9 9.5 4.9 311 6 324 165 3.6 0 3.8 3.5 12/09/2005 18:00:00 8.6 1 11.5 6.1 8.6 1 11.5 6.1 7.9 1.3 11.1 4.6 315 9 311 165 3.6 0 3.8 3.5 12/09/2005 18:10:00 8.3 1 10.3 4.9 8.2 0.9 9.9 4.9 7.8 1 9.9 4.9 318 9 317 165 3.6 0 3.8 3.5 12/09/2005 18:20:00 8.3 0.8 9.9 5.7 8.2 0.8 9.9 5.7 8 1 9.9 5.3 319 7 314 165 3.6 0 3.8 3.5 12/09/2005 18:30:00 8.2 1 10.3 5.7 8.1 1 10.3 5.7 8 1 9.9 5.7 331 8 341 165 3.8 0 4 3.5 12/09/2005 18:40:00 7.8 1 11.5 5.3 7.8 1 12.6 4.9 7.5 1.1 11.8 4.6 335 9 341 165 4 0 4.3 3.8 12/09/2005 18:50:00 6.5 1 8.8 3.8 6.4 1 8.8 4.2 5.9 1 8.4 3 311 12 320 165 4 0 4.3 3.8 12/09/2005 19:00:00 6.4 0.9 8.8 4.2 6.3 0.9 8.8 4.6 5.6 1.2 8.8 3 314 12 332 165 4 0 4.3 3.8 12/09/2005 19:10:00 5.5 1 8 3 5.4 1 7.6 3 4.3 0.8 6.8 1.9 303 12 290 165 3.8 0 4 3.5 12/09/2005 19:20:00 5.7 0.9 8 3.8 5.5 0.9 8 3.8 4.7 0.8 7.2 3 305 11 306 165 3.8 0 4 3.5 12/09/2005 19:30:00 5.5 0.8 7.2 3.8 5.4 0.8 7.2 3.4 4.7 0.7 6.5 2.6 306 10 308 165 4 0 4.3 3.8 12/09/2005 19:40:00 5.4 0.7 7.6 3.8 5.4 0.7 7.2 3.8 4.3 0.8 6.8 2.3 296 10 298 165 4.1 0 4.3 4 12/09/2005 19:50:00 7.5 1.3 9.9 4.6 7.5 1.4 9.9 4.2 6.9 1.4 10.3 3.4 287 7 282 165 4.1 0 4.3 4 12/09/2005 20:00:00 8.5 0.9 10.3 6.5 8.5 0.9 10.7 6.5 6.8 1.2 9.9 4.2 293 5 287 165 4 0 4.3 3.8 12/09/2005 20:10:00 7.8 1 9.9 4.9 7.8 1 9.5 4.9 5.5 0.8 8 3.4 298 4 290 165 4.1 0 4.3 4 12/09/2005 20:20:00 6.4 0.7 8 4.6 6.4 0.7 8 4.9 4.4 0.6 6.1 3 299 4 301 165 4.1 0 4.3 4 12/09/2005 20:30:00 6.5 0.5 8 4.6 6.5 0.6 7.6 4.9 4.9 0.7 6.8 3.4 304 4 307 165 4.1 0 4.3 4 12/09/2005 20:40:00 6 0.7 7.6 3.8 5.9 0.7 7.6 4.2 4.7 0.7 7.2 3 305 7 300 165 4.2 0 4.5 4.3 12/09/2005 20:50:00 6 0.6 7.6 4.2 6 0.7 7.6 3.8 4.9 0.6 6.1 3 307 5 301 165 4.3 0 4.5 4.3 12/09/2005 21:00:00 5.7 0.6 7.2 3.8 5.7 0.6 7.2 4.2 4.3 0.7 6.5 2.3 300 7 297 165 4.4 0 4.5 4.3 12/09/2005 21:10:00 5.2 0.4 6.1 4.6 5.2 0.4 6.1 4.2 3.8 0.6 5.7 2.6 295 4 286 165 4.4 0 4.5 4.3 12/09/2005 21:20:00 4.6 0.3 5.3 3.8 4.5 0.3 5.3 3.8 3.2 0.4 4.6 2.3 297 2 295 165 4.3 0 4.5 4.3 12/09/2005 21:30:00 4.6 0.4 5.3 3.8 4.5 0.4 5.3 3.8 3.6 0.6 4.9 2.3 291 3 291 165 4.4 0 4.5 4.3 12/09/2005 21:40:00 4.7 0.3 5.3 3.8 4.6 0.3 5.3 3.8 3.6 0.6 5.3 2.3 291 4 286 165 4.4 0 4.5 4.3 12/09/2005 21:50:00 4.5 0.3 5.3 3.8 4.5 0.4 5.3 3.4 4.2 0.4 5.3 2.6 280 4 282 165 4.4 0 4.5 4.3 12/09/2005 22:00:00 4 0.2 4.6 3.4 4 0.2 4.6 3.4 3.8 0.3 4.2 3 275 3 281 165 4.6 0 4.8 4.5 12/09/2005 22:10:00 4.1 0.2 4.6 3.8 4.1 0.2 4.6 3.4 3.9 0.2 4.6 3.4 276 2 276 165 4.6 0 4.8 4.5 12/09/2005 22:20:00 3.5 0.4 4.2 2.3 3.7 0.2 4.2 3 3.5 0.3 4.2 3 270 4 274 165 4.6 0 4.8 4.5 12/09/2005 22:30:00 2.7 0.5 3.8 1.5 2.8 0.6 3.8 1.5 2.8 0.6 3.8 1.5 242 13 250 165 4.6 0 4.8 4.5 12/09/2005 22:40:00 2.1 0.4 3 1.1 1.9 0.5 3 0.7 1.9 0.5 3.4 1.1 226 10 234 165 4.7 0 4.8 4.8 12/09/2005 22:50:00 1.7 0.4 2.6 0.7 1.4 0.6 2.6 0.4 1.3 0.6 2.6 0.4 220 9 207 165 4.8 0 5 4.8 12/09/2005 23:00:00 0.8 0.5 1.9 0.4 0.6 0.4 1.9 0.4 0.6 0.4 1.9 0.4 231 22 214 165 5 0 5 4.8 12/09/2005 23:10:00 0.8 0.6 2.6 0.4 0.6 0.5 2.3 0.4 0.6 0.4 1.5 0.4 262 90 164 165 5.1 0 5.2 5 12/09/2005 23:20:00 2.3 0.5 3.4 1.5 2.1 0.5 3 1.1 2.4 0.4 3 1.5 163 8 163 165 5 0 5.2 4.8 12/09/2005 23:30:00 1.4 0.3 2.3 0.7 1.2 0.3 1.9 0.4 1.4 0.3 2.3 0.7 169 4 159 165 4.8 0 5 4.8 12/09/2005 23:40:00 1.2 0.5 1.9 0.4 0.9 0.5 1.9 0.4 1.1 0.6 2.3 0.4 155 8 163 165 4.7 0 5 4.5 12/09/2005 23:50:00 0.5 0.3 1.5 0.4 0.4 0.1 1.1 0.4 0.4 0 0.4 0.4 147 1 150 165 4.6 0 4.8 4.5 12/10/2005 00:00:00 1.2 0.2 1.5 0.7 0.6 0.3 1.1 0.4 0.9 0.3 1.5 0.4 155 1 151 165 4.6 0 4.8 4.5 12/10/2005 00:10:00 1.2 0.3 1.9 0.7 0.7 0.4 1.5 0.4 1 0.3 1.5 0.4 150 7 156 165 4.5 0 4.8 4.3 12/10/2005 00:20:00 0.5 0.3 1.5 0.4 0.4 0 0.7 0.4 0.4 0.1 0.7 0.4 146 15 142 165 4.3 0 4.5 4.3 12/10/2005 00:30:00 1 0.3 1.9 0.4 0.4 0.1 1.5 0.4 0.5 0.4 1.9 0.4 211 3 204 165 4.2 0 4.5 4.3 12/10/2005 00:40:00 2.2 0.5 3.4 1.5 1.9 0.6 3 1.1 2.1 0.5 3.4 1.1 198 3 194 165 4.4 0 4.8 4.3 12/10/2005 00:50:00 3.7 0.3 4.6 2.6 3.5 0.3 4.2 2.6 3.7 0.3 4.2 3 194 3 198 165 4.3 0.1 4.5 4.3 12/10/2005 01:00:00 3.8 0.3 4.6 3 3.6 0.3 4.2 3 3.8 0.3 4.6 3 191 2 193 165 4.2 0 4.5 4.3 12/10/2005 01:10:00 3.1 0.2 3.8 2.6 2.9 0.2 3.4 2.6 2.9 0.2 3.4 2.3 200 6 189 165 4.1 0 4.5 4.3 12/10/2005 01:20:00 3 0.3 3.4 2.6 2.9 0.3 3.4 2.3 2.9 0.3 3.8 2.3 205 5 206 165 4.4 0 4.8 4.3 12/10/2005 01:30:00 2.8 0.4 3.4 1.5 2.7 0.4 3.4 1.1 2.6 0.5 3.8 1.5 215 2 214 165 4.6 0 4.8 4.5 12/10/2005 01:40:00 1.9 0.6 3 0.4 1.5 0.7 2.6 0.4 1.7 0.4 2.6 0.7 187 15 213 165 4.4 0.1 4.8 4.3 12/10/2005 01:50:00 3 0.7 4.6 1.9 2.8 0.8 4.6 1.1 2.7 0.7 4.6 1.5 184 11 197 165 4.1 0.1 4.5 4.3 12/10/2005 02:00:00 3.6 0.3 4.2 3 3.5 0.3 4.2 3 3.2 0.4 4.2 2.3 204 3 211 165 4.1 0 4.3 4 12/10/2005 02:10:00 3.5 0.3 4.2 3 3.4 0.2 4.2 3 3.5 0.3 4.2 2.6 208 5 207 165 4 0 4.3 3.8 12/10/2005 02:20:00 4.4 0.6 5.7 3 4.5 0.7 5.7 3 4.5 0.6 5.7 3.4 219 6 212 165 4.1 0 4.3 4 12/10/2005 02:30:00 4.4 0.4 5.3 3 4.3 0.5 4.9 3 4.4 0.5 5.3 3.4 190 9 203 165 4.1 0.1 4.5 3.8 12/10/2005 02:40:00 4.8 0.7 6.8 3 4.5 0.7 6.5 3 4.3 0.7 6.1 2.3 181 8 191 165 3.9 0 4.3 3.8 12/10/2005 02:50:00 5.5 0.6 6.8 3.8 5.2 0.6 6.8 3.4 4.9 0.7 6.8 3 186 6 187 165 3.6 0.1 4 3.5 12/10/2005 03:00:00 5.8 0.4 6.8 4.6 5.8 0.4 6.8 4.6 5.6 0.5 6.8 3.8 198 6 193 165 3.6 0 3.8 3.5 12/10/2005 03:10:00 6.3 0.6 7.6 4.6 6.4 0.7 8 4.6 5.9 0.8 7.6 3.8 214 8 219 165 3.9 0 4.3 3.8 12/10/2005 03:20:00 6.9 0.6 8.4 4.9 7.1 0.6 8.4 4.9 6.5 0.7 8 4.2 217 5 213 165 3.8 0 4 3.8 12/10/2005 03:30:00 7.3 0.6 8.4 5.3 7.4 0.6 8.8 5.3 6.9 0.6 8.4 4.9 212 3 211 165 3.7 0 4 3.5 12/10/2005 03:40:00 7.1 0.7 8.4 4.9 7.3 0.7 8.8 5.3 6.8 0.8 8.8 4.6 213 3 216 165 3.8 0 4 3.5 12/10/2005 03:50:00 6.4 0.4 7.2 5.3 6.5 0.4 7.6 5.3 6.1 0.5 7.2 4.6 214 4 215 165 3.9 0 4.3 3.8 12/10/2005 04:00:00 6.4 0.9 9.1 4.2 6.5 1 9.1 4.2 6.2 1 8.8 4.2 219 6 221 165 4 0 4.3 3.8 12/10/2005 04:10:00 6.6 1 8.8 4.2 6.8 1 8.8 4.6 6.6 1 8.8 3.8 220 3 220 165 3.8 0 4 3.8 12/10/2005 04:20:00 5.9 0.5 7.2 4.2 5.9 0.5 7.2 4.6 5.7 0.6 7.2 4.2 226 4 227 165 3.9 0 4.3 3.8 12/10/2005 04:30:00 6.2 0.5 7.2 4.9 6.3 0.5 7.2 4.9 6.2 0.5 7.2 4.6 219 7 225 165 4 0 4.3 3.8 12/10/2005 04:40:00 5.8 0.5 6.8 3.8 5.8 0.5 6.8 3.4 5.6 0.6 6.8 3.8 208 5 209 165 4 0 4.3 3.8 12/10/2005 04:50:00 5.4 0.7 7.2 3.4 5.3 0.7 6.8 3.4 5.1 0.6 6.5 3.8 200 7 198 165 3.9 0 4.3 3.5 12/10/2005 05:00:00 5.6 0.4 6.5 4.2 5.4 0.4 6.1 4.2 5.4 0.6 6.5 3.4 193 3 201 165 3.6 0 3.8 3.5 12/10/2005 05:10:00 5.7 0.5 6.8 4.6 5.6 0.5 6.8 4.6 5.8 0.5 7.2 4.6 191 5 196 165 3.9 0 4 3.8 12/10/2005 05:20:00 6.4 0.5 7.2 4.2 6.2 0.5 7.2 4.6 6.3 0.6 7.6 4.6 189 3 188 165 3.8 0 4 3.5 12/10/2005 05:30:00 7.2 0.6 8.8 5.7 7.1 0.6 8.4 5.3 7.2 0.6 8.4 5.7 190 4 190 165 3.9 0 4.3 3.8 12/10/2005 05:40:00 8.1 0.5 9.1 6.5 7.9 0.6 9.1 6.5 7.9 0.6 9.1 6.5 191 4 196 165 3.7 0 3.8 3.5 12/10/2005 05:50:00 9 0.5 10.3 7.6 8.9 0.5 10.3 7.6 8.9 0.6 10.3 6.5 192 3 192 165 3.6 0 3.8 3.5 12/10/2005 06:00:00 8.6 0.7 10.3 6.5 8.7 0.7 10.3 6.5 8.4 0.9 10.3 6.1 198 4 191 165 3.6 0 3.8 3.5 12/10/2005 06:10:00 6.9 0.5 8.4 5.3 6.9 0.5 8.4 5.3 6.7 0.6 8.4 4.9 195 4 200 165 3.6 0 3.8 3.5 12/10/2005 06:20:00 6.4 0.5 7.6 5.3 6.3 0.5 7.6 5.3 6.3 0.5 7.6 4.9 197 4 204 165 3.6 0 3.8 3.5 12/10/2005 06:30:00 6.3 0.5 7.6 4.9 6.1 0.5 7.6 4.9 6.2 0.5 7.6 4.6 190 5 196 165 3.6 0 3.8 3.5 12/10/2005 06:40:00 6.1 0.8 8 4.2 5.9 0.8 8 3.8 5.9 0.9 8 3.8 182 9 194 165 3.6 0.1 3.8 3.5 12/10/2005 06:50:00 6 0.9 7.6 3.4 5.9 0.9 7.6 3.8 5.9 0.9 8 3.8 191 6 186 165 3.5 0 3.5 3.3 12/10/2005 07:00:00 6.4 0.5 7.6 4.9 6.3 0.6 8 4.9 6.1 0.6 7.6 4.6 195 6 193 165 3.4 0 3.5 3.3 12/10/2005 07:10:00 6.2 0.8 8.4 4.6 6.2 0.9 8.4 4.6 6.2 0.8 8 4.6 196 5 201 165 3.5 0 3.5 3.5 12/10/2005 07:20:00 5.1 0.8 6.8 2.6 5 0.8 6.8 2.6 4.9 0.8 6.8 2.6 201 11 210 165 3.6 0 3.5 3.3 12/10/2005 07:30:00 4.5 0.9 7.2 2.3 4.4 1 7.2 1.9 4.2 0.7 6.5 2.3 205 10 203 165 3.5 0 3.5 3.5 12/10/2005 07:40:00 4.6 0.9 6.5 2.6 4.5 0.9 6.5 2.6 4.5 0.9 6.5 2.6 203 7 207 165 3.5 0 3.5 3.3 12/10/2005 07:50:00 4.7 0.9 8 3 4.6 0.9 7.6 3 4.6 0.8 6.8 2.6 200 9 194 165 3.3 0 3.5 3.3 12/10/2005 08:00:00 6.4 0.9 8 3.8 6.4 0.9 8.4 4.2 6.2 0.9 8.8 4.6 194 8 190 165 3.2 0 3.5 3 12/10/2005 08:10:00 7.9 0.5 9.1 6.1 7.9 0.5 9.1 6.5 7.8 0.7 9.5 5.7 196 5 184 165 3.3 0 3.5 3.3 12/10/2005 08:20:00 6.5 0.7 8 4.9 6.4 0.7 8 4.9 6.4 0.9 8.8 3.8 200 6 195 165 3.4 0 3.5 3.3 12/10/2005 08:30:00 6.6 0.6 8.4 4.2 6.7 0.6 8.8 4.2 6.3 0.7 8 4.2 206 4 208 165 3.2 0 3.5 3 12/10/2005 08:40:00 6.2 0.6 7.6 4.9 6.2 0.6 7.6 4.9 6.2 0.7 8 4.2 200 3 201 165 3.2 0 3.3 3 12/10/2005 08:50:00 7.2 0.6 8.8 5.3 7.3 0.6 8.8 5.3 6.8 0.8 8.8 4.6 201 3 202 165 3.1 0 3.3 3 12/10/2005 09:00:00 7.4 0.6 8.8 5.7 7.4 0.6 8.8 5.7 7.2 0.7 8.8 5.3 198 4 197 165 3.2 0 3.3 3 12/10/2005 09:10:00 6.7 0.6 8 4.9 6.7 0.6 8 5.3 6.5 0.8 8.4 4.6 199 5 198 165 3 0.1 3.3 2.8 12/10/2005 09:20:00 8.1 0.5 9.9 6.1 8.1 0.5 9.5 6.1 8.1 0.7 9.5 6.1 190 4 189 165 3.3 0 3.5 3 12/10/2005 09:30:00 6.7 0.8 8.8 4.6 6.7 0.8 8.8 4.9 6.5 0.9 8.8 4.6 190 6 190 165 3.2 0 3.5 3 12/10/2005 09:40:00 7.5 0.5 8.4 6.5 7.4 0.5 8.4 6.5 7.5 0.6 9.1 5.7 190 2 191 165 3.2 0 3.5 3 12/10/2005 09:50:00 7.5 0.5 8.8 5.7 7.4 0.5 8.8 6.1 7.6 0.6 8.8 5.7 191 3 189 165 3.3 0 3.5 3.3 12/10/2005 10:00:00 7.6 0.8 9.5 6.1 7.7 0.8 9.5 6.1 7.9 0.9 9.9 5.7 197 4 193 165 3.3 0 3.5 3.3 12/10/2005 10:10:00 8.1 0.6 9.5 6.5 8.1 0.6 9.5 6.5 8.2 0.6 9.5 6.5 194 5 184 165 3.3 0 3.8 3.3 12/10/2005 10:20:00 7.2 0.5 8.8 6.1 7.2 0.5 8.4 6.1 7.4 0.6 8.8 5.7 194 5 201 165 3.3 0 3.5 3.3 12/10/2005 10:30:00 7.3 0.8 8.8 5.3 7.4 0.8 9.1 5.3 7.4 0.8 9.1 5.3 200 5 199 165 3.5 0 3.8 3.3 12/10/2005 10:40:00 5.9 0.4 6.8 4.6 6 0.4 6.8 4.6 5.8 0.5 6.8 4.2 206 3 205 165 3.6 0 3.8 3.5 12/10/2005 10:50:00 5.1 0.5 6.8 4.2 5.2 0.5 6.1 4.2 5 0.5 6.5 4.2 210 4 213 165 3.6 0 3.8 3.5 12/10/2005 11:00:00 5 0.5 6.1 3.8 5 0.5 6.5 3.8 5.1 0.4 6.5 3.8 203 5 197 165 3.5 0 3.8 3.5 12/10/2005 11:10:00 4 0.5 5.3 3 3.8 0.5 4.9 2.6 4.1 0.5 5.3 3 182 10 201 165 3.5 0 3.8 3.3 12/10/2005 11:20:00 4.6 0.4 5.7 3.4 4.3 0.4 5.3 3 4.4 0.5 5.7 3 175 3 173 165 3.2 0 3.5 3 12/10/2005 11:30:00 5.2 0.5 6.5 4.2 4.9 0.4 6.1 4.2 4.9 0.5 6.1 3.8 174 4 173 165 3.2 0 3.5 3 12/10/2005 11:40:00 5 0.4 6.1 4.2 4.7 0.4 5.7 3.8 4.8 0.4 5.7 3.8 170 4 175 165 3.3 0 3.5 3.3 12/10/2005 11:50:00 5.1 0.5 6.5 4.2 4.8 0.5 6.1 3.8 4.9 0.5 6.5 3.8 168 5 173 165 3.5 0 3.5 3.3 12/10/2005 12:00:00 4.5 0.5 6.1 3.4 4.2 0.4 5.7 3.4 4.5 0.4 5.7 3.4 168 10 165 165 3.5 0 3.5 3.5 12/10/2005 12:10:00 4.8 0.7 6.5 3.4 4.5 0.6 6.1 3 4.7 0.6 6.5 3.4 162 7 165 165 3.5 0 3.5 3.3 12/10/2005 12:20:00 4.1 0.5 5.3 3 3.9 0.5 4.9 3 4.1 0.5 5.3 3 162 3 162 165 3.3 0 3.5 3.3 12/10/2005 12:30:00 4.1 0.4 4.9 3 3.9 0.4 4.9 3 4 0.4 4.9 3 162 6 159 165 3.3 0 3.5 3.3 12/10/2005 12:40:00 4.3 0.4 5.3 3.4 4.1 0.4 4.9 3 4.3 0.4 5.3 3 161 8 161 165 3.3 0 3.5 3.3 12/10/2005 12:50:00 4.2 0.3 4.9 3.4 4 0.3 4.6 3.4 4.1 0.3 4.9 3 159 4 161 165 3.4 0 3.5 3.3 12/10/2005 13:00:00 3.9 0.3 4.6 3 3.7 0.3 4.6 2.6 3.9 0.4 4.9 3 158 4 149 165 3.5 0 3.5 3.3 12/10/2005 13:10:00 3.7 0.2 4.2 3 3.5 0.2 4.2 3 3.7 0.3 4.6 3 158 8 162 165 3.6 0 3.8 3.5 12/10/2005 13:20:00 3.9 0.3 4.6 3 3.7 0.3 4.2 3 3.8 0.3 4.6 3 154 3 156 165 3.8 0 3.8 3.5 12/10/2005 13:30:00 4.4 0.4 5.3 3.8 4.3 0.4 5.3 3.4 4.4 0.4 5.3 3.4 150 3 146 165 3.8 0 4 3.8 12/10/2005 13:40:00 5 0.5 6.1 3.4 4.8 0.4 5.7 3.4 4.9 0.4 5.7 3.8 152 3 155 165 3.9 0 4 3.8 12/10/2005 13:50:00 5 0.3 6.1 4.2 4.8 0.3 5.7 4.2 4.9 0.3 5.7 3.8 151 3 151 165 4 0 4.3 3.8 12/10/2005 14:00:00 4.9 0.4 6.1 3.8 4.8 0.4 5.7 3.8 4.8 0.4 5.7 3.8 153 4 158 165 4.1 0 4.3 4 12/10/2005 14:10:00 4.7 0.5 6.8 3.4 4.6 0.5 6.8 3 4.6 0.5 6.8 3 151 10 117 165 4.1 0 4.3 4 12/10/2005 14:20:00 6.1 0.7 8.8 4.2 6.1 0.7 8.4 4.2 6 0.7 8.4 4.6 148 9 145 165 4.2 0 4.5 4.3 12/10/2005 14:30:00 6 0.9 8 3 5.9 0.8 7.6 2.6 6.1 0.8 7.6 3.8 150 13 153 165 4.2 0 4.5 4.3 12/10/2005 14:40:00 6.7 0.6 8.4 4.9 6.5 0.6 8 4.9 6.7 0.6 8.4 5.3 158 10 156 165 4.1 0 4.5 4.3 12/10/2005 14:50:00 6.7 0.7 8.4 4.9 6.6 0.7 8.4 4.6 6.7 0.8 8.8 4.9 151 9 156 165 4.1 0 4.3 4 12/10/2005 15:00:00 7.2 0.6 8.8 6.1 7 0.6 8.4 5.7 7.2 0.6 9.1 6.1 152 6 153 165 4.1 0 4.3 4 12/10/2005 15:10:00 7.6 0.6 8.8 6.1 7.6 0.6 8.8 6.1 7.4 0.6 8.8 6.1 146 4 149 165 4 0 4.3 3.8 12/10/2005 15:20:00 6.9 0.4 8 6.1 6.9 0.4 8 6.1 6.7 0.5 8 5.7 150 2 148 165 4 0 4.3 3.8 12/10/2005 15:30:00 6.2 0.5 7.2 4.9 6.2 0.5 7.6 4.9 6.1 0.5 7.2 4.9 146 3 147 165 4 0 4.3 3.8 12/10/2005 15:40:00 6 0.3 6.5 5.3 6 0.3 6.5 5.3 5.9 0.3 6.5 4.9 146 3 148 165 4 0 4.3 3.8 12/10/2005 15:50:00 6.2 0.4 7.2 4.9 6.1 0.4 7.2 4.9 6 0.5 7.2 4.2 145 4 148 165 4 0 4 3.8 12/10/2005 16:00:00 6.7 0.6 8.4 5.3 6.7 0.6 8 4.9 6.5 0.6 8 4.9 144 4 144 165 3.9 0 4 3.8 12/10/2005 16:10:00 6.6 0.6 8 4.9 6.6 0.6 7.6 4.9 6.4 0.6 7.6 4.6 142 5 148 165 4 0 4.3 3.8 12/10/2005 16:20:00 5.5 0.6 7.2 4.6 5.5 0.6 7.2 4.2 5.5 0.6 7.2 4.2 144 5 143 165 4 0 4.3 3.8 12/10/2005 16:30:00 5.6 0.4 6.5 4.6 5.6 0.4 6.8 4.6 5.5 0.5 6.8 4.6 143 6 150 165 4 0 4.3 3.8 12/10/2005 16:40:00 6.5 0.6 8 4.9 6.4 0.5 8 4.9 6.3 0.6 7.6 4.6 140 6 124 165 4 0 4.3 4 12/10/2005 16:50:00 6 0.7 7.6 3.8 6 0.7 7.2 3.8 5.9 0.7 7.2 3.8 139 8 149 165 4.1 0 4.3 4 12/10/2005 17:00:00 6.1 0.6 8 4.2 6.2 0.7 8.4 4.2 6 0.6 7.6 4.6 137 7 121 165 4.1 0 4.3 4 12/10/2005 17:10:00 6.4 0.7 8 4.2 6.4 0.7 8.4 4.2 6.2 0.8 7.6 3.8 138 5 133 165 4.1 0 4.3 4.3 12/10/2005 17:20:00 6.1 0.7 8.4 4.6 6.2 0.7 8.4 4.6 6 0.7 7.6 4.6 131 7 135 165 4.1 0 4.3 3.8 12/10/2005 17:30:00 7.9 0.8 9.9 6.1 8 0.8 9.9 6.1 7.8 0.8 9.9 6.1 126 5 130 165 4 0 4.3 3.8 12/10/2005 17:40:00 7.1 0.6 8.8 6.1 7.1 0.6 9.1 5.3 7 0.5 9.1 6.1 127 5 133 165 3.8 0.1 4 3.5 12/10/2005 17:50:00 6.9 0.8 9.5 4.6 7 0.8 9.9 4.6 6.8 0.8 8.8 4.9 129 8 128 165 3.6 0 3.8 3.5 12/10/2005 18:00:00 6.4 0.8 9.5 4.6 6.4 0.9 9.5 4.6 6.2 0.8 8.4 4.2 133 12 129 165 3.6 0 3.8 3.5 12/10/2005 18:10:00 9.1 1.3 11.8 4.9 9.2 1.3 12.2 5.3 8.8 1.5 11.8 4.9 123 5 118 165 4 0.1 4.3 3.5 12/10/2005 18:20:00 9.8 0.8 12.2 7.2 9.9 0.8 12.2 7.6 9.6 0.9 12.2 7.2 135 9 119 165 4 0 4.3 3.8 12/10/2005 18:30:00 9.1 1 11.5 7.2 9.2 1 11.8 7.2 8.9 1 11.5 6.1 137 7 132 165 4 0 4.3 3.8 12/10/2005 18:40:00 9.7 1.1 12.6 7.2 9.7 1.2 13 7.2 9.5 1.2 12.6 6.5 139 8 133 165 3.8 0 4 3.5 12/10/2005 18:50:00 8.8 1 11.1 6.1 8.9 1 11.5 6.1 8.7 1 11.5 5.7 132 8 128 165 3.5 0 3.5 3.3 12/10/2005 19:00:00 8 0.7 10.3 6.5 8.1 0.7 10.3 6.5 7.9 0.7 9.9 6.1 131 6 126 165 3.3 0 3.5 3 12/10/2005 19:10:00 7.4 0.6 9.1 5.7 7.5 0.6 9.1 6.1 7.2 0.6 9.9 5.3 126 5 113 165 3.1 0 3.3 3 12/10/2005 19:20:00 7.8 0.7 9.1 5.3 7.9 0.7 9.9 5.3 7.5 0.7 9.1 5.7 120 5 118 165 3 0 3.3 2.8 12/10/2005 19:30:00 7.8 0.7 9.5 6.1 7.9 0.7 9.9 6.1 7.7 0.7 9.5 5.3 123 6 115 165 2.9 0 3 2.8 12/10/2005 19:40:00 7.4 0.6 9.9 5.7 7.5 0.6 9.9 5.7 7.2 0.7 9.9 5.3 124 7 118 165 2.9 0 3 2.8 12/10/2005 19:50:00 7.5 0.9 9.9 4.9 7.6 1 9.9 5.3 7.2 1 10.3 4.6 125 7 129 165 2.8 0 3 2.6 12/10/2005 20:00:00 7 1 11.1 4.9 7.2 1 11.5 4.9 6.8 1 11.5 4.6 123 7 106 165 2.8 0 2.8 2.8 12/10/2005 20:10:00 7.7 0.7 9.5 5.3 7.8 0.7 9.5 5.7 7.4 0.8 9.9 4.6 124 8 119 165 2.9 0 3 2.8 12/10/2005 20:20:00 7.8 1 10.3 5.7 7.9 1 10.3 4.9 7.7 1 9.5 4.9 126 7 118 165 2.9 0 3 2.8 12/10/2005 20:30:00 7 0.8 9.1 4.9 7.1 0.8 9.1 4.6 7 0.9 9.1 4.6 130 8 140 165 2.9 0 3 2.8 12/10/2005 20:40:00 9.1 0.6 10.3 6.8 9.1 0.6 10.3 6.8 9.1 0.7 10.3 6.5 150 6 151 165 2.6 0.2 3 2.3 12/10/2005 20:50:00 7.8 0.6 9.5 6.1 7.7 0.6 9.5 6.1 7.8 0.7 9.5 5.7 144 5 145 165 2.1 0.1 2.6 1.8 12/10/2005 21:00:00 6.4 0.8 8.8 4.6 6.4 0.8 8.4 4.6 6.4 0.9 8.4 4.2 139 6 145 165 1.8 0 2.1 1.8 12/10/2005 21:10:00 4.4 0.5 6.1 3 4.4 0.6 6.1 3 4.3 0.6 6.1 2.3 132 8 142 165 1.8 0 1.8 1.6 12/10/2005 21:20:00 5.5 0.5 6.8 3.8 5.4 0.6 6.8 3.8 5.5 0.5 6.8 3.8 134 0 134 165 1.8 0 1.8 1.6 12/10/2005 21:30:00 4.6 0.4 5.7 3.4 4.5 0.4 5.7 3 4.5 0.5 5.7 3.4 134 0 135 165 1.8 0 1.8 1.6 12/10/2005 21:40:00 3.8 0.7 5.3 2.3 3.7 0.8 5.3 2.3 3.8 0.8 5.3 1.9 134 0 135 165 1.8 0 1.8 1.8 12/10/2005 21:50:00 2.7 0.4 3.4 1.9 2.5 0.4 3.4 1.5 2.6 0.3 3.4 1.9 134 0 135 165 1.8 0 1.8 1.8 12/10/2005 22:00:00 2.9 0.6 4.2 1.5 2.7 0.6 3.8 1.1 2.8 0.5 4.2 1.5 135 0 135 165 1.9 0 2.1 1.8 12/10/2005 22:10:00 2 0.5 3 0.4 1.8 0.5 2.6 0.4 1.9 0.5 3 0.4 135 0 135 165 2 0 2.3 1.8 12/10/2005 22:20:00 1.9 0.5 3 0.7 1.7 0.6 3 0.4 1.7 0.5 3 0.4 135 0 135 165 2.1 0 2.3 1.8 12/10/2005 22:30:00 1.5 0.5 2.6 0.4 1.2 0.6 2.3 0.4 1.4 0.5 2.3 0.4 135 0 135 165 2.1 0 2.3 1.8 12/10/2005 22:40:00 0.8 0.4 1.9 0.4 0.5 0.2 1.5 0.4 0.6 0.4 1.9 0.4 134 0 135 165 2.1 0 2.3 1.8 12/10/2005 22:50:00 0.8 0.5 2.6 0.4 0.6 0.4 2.6 0.4 0.4 0.2 1.9 0.4 134 0 134 165 1.8 0 1.8 1.6 12/10/2005 23:00:00 1.8 0.5 3 0.4 1.6 0.7 3 0.4 1.6 0.7 2.6 0.4 131 1 133 165 2 0.2 2.3 1.8 12/10/2005 23:10:00 1 0.5 1.9 0.4 0.6 0.4 1.5 0.4 0.7 0.5 1.9 0.4 129 1 130 165 2.3 0 2.6 2.3 12/10/2005 23:20:00 0.5 0.2 1.1 0.4 0.4 0 0.4 0.4 0.7 0.3 1.5 0.4 127 0 128 165 2.4 0 2.6 2.3 12/10/2005 23:30:00 0.5 0.3 1.5 0.4 0.4 0 0.4 0.4 0.5 0.2 1.5 0.4 127 0 128 165 2.4 0 2.6 2.3 12/10/2005 23:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.7 0.4 127 0 165 165 2.3 0 2.6 2.3 12/10/2005 23:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 127 0 165 165 2.2 0 2.3 2.3 12/11/2005 00:00:00 0.4 0.1 0.7 0.4 0.4 0 0.4 0.4 0.4 0.2 1.1 0.4 120 8 106 165 2.2 0 2.3 2.1 12/11/2005 00:10:00 0.5 0.2 1.1 0.4 0.4 0.1 0.7 0.4 1.1 0.2 1.5 0.4 57 20 91 165 2.3 0 2.3 2.3 12/11/2005 00:20:00 0.6 0.4 1.9 0.4 0.5 0.3 1.5 0.4 0.7 0.4 1.5 0.4 44 1 44 165 2.3 0 2.6 2.3 12/11/2005 00:30:00 0.8 0.3 1.9 0.4 0.5 0.3 1.9 0.4 0.7 0.3 1.5 0.4 47 1 46 165 2.3 0 2.6 2.3 12/11/2005 00:40:00 0.9 0.2 1.1 0.4 0.5 0.2 1.1 0.4 1 0.2 1.5 0.4 36 2 43 165 2.2 0 2.3 2.1 12/11/2005 00:50:00 0.5 0.2 1.1 0.4 0.4 0 0.7 0.4 0.4 0.2 1.1 0.4 36 1 35 165 2.3 0 2.6 2.3 12/11/2005 01:00:00 0.4 0 0.7 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 37 0 37 165 2.3 0 2.6 2.3 12/11/2005 01:10:00 0.4 0.1 1.1 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 37 0 37 165 2.3 0 2.3 2.3 12/11/2005 01:20:00 0.9 0.4 1.5 0.4 0.5 0.2 1.5 0.4 1.1 0.5 1.9 0.4 27 10 32 165 2.2 0 2.3 2.1 12/11/2005 01:30:00 0.8 0.4 1.5 0.4 0.5 0.2 1.5 0.4 1 0.4 1.5 0.4 8 0 9 165 2.1 0 2.3 2.1 12/11/2005 01:40:00 0.4 0.1 0.7 0.4 0.4 0.1 0.7 0.4 0.4 0.1 1.1 0.4 13 5 9 165 2 0 2.3 1.8 12/11/2005 01:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 18 0 165 165 2 0 2.3 1.8 12/11/2005 02:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 18 0 165 165 1.9 0 2.1 1.8 12/11/2005 02:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 18 0 165 165 1.9 0 2.1 1.8 12/11/2005 02:20:00 0.4 0.2 1.1 0.4 0.4 0 0.4 0.4 0.5 0.2 1.1 0.4 18 0 18 165 1.9 0 2.1 1.8 12/11/2005 02:30:00 0.7 0.3 1.1 0.4 0.4 0.1 1.1 0.4 0.8 0.4 1.5 0.4 18 0 18 165 1.9 0 2.1 1.8 12/11/2005 02:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 18 0 165 165 2.1 0 2.3 1.8 12/11/2005 02:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 18 0 165 165 2.2 0 2.3 2.1 12/11/2005 03:00:00 0.4 0 0.7 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 17 17 173 165 2.3 0 2.3 2.1 12/11/2005 03:10:00 0.5 0.2 1.1 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 166 2 173 165 2.1 0 2.3 1.8 12/11/2005 03:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 165 0 165 165 2 0 2.3 1.8 12/11/2005 03:30:00 0.5 0.3 1.5 0.4 0.4 0.1 1.1 0.4 0.6 0.3 1.5 0.4 165 0 165 165 2.1 0 2.3 1.8 12/11/2005 03:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 165 0 165 165 2.1 0 2.3 1.8 12/11/2005 03:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 174 20 165 165 2 0 2.1 1.8 12/11/2005 04:00:00 0.9 0.5 1.5 0.4 0.7 0.4 1.5 0.4 1 0.5 1.9 0.4 221 5 217 165 1.9 0 2.1 1.8 12/11/2005 04:10:00 1.4 0.2 1.9 1.1 1.2 0.2 1.5 0.7 1.5 0.2 1.9 0.7 226 0 227 165 2 0 2.3 1.8 12/11/2005 04:20:00 1.5 0.2 1.9 0.7 1.2 0.3 1.9 0.4 1.6 0.2 1.9 1.1 226 0 227 165 2.1 0 2.3 1.8 12/11/2005 04:30:00 0.4 0.2 1.1 0.4 0.4 0.1 0.7 0.4 0.5 0.4 1.5 0.4 226 0 227 165 2 0 2.3 1.8 12/11/2005 04:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 226 0 165 165 2 0 2.1 1.8 12/11/2005 04:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 226 0 165 165 1.9 0 2.3 1.8 12/11/2005 05:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 226 0 165 165 2 0 2.3 1.8 12/11/2005 05:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 231 15 165 165 1.9 0 2.1 1.8 12/11/2005 05:20:00 0.8 0.4 1.5 0.4 0.4 0 0.4 0.4 0.8 0.4 1.5 0.4 306 17 317 165 1.9 0 1.8 1.8 12/11/2005 05:30:00 0.4 0.1 0.7 0.4 0.4 0 0.4 0.4 0.4 0.1 0.7 0.4 317 0 317 165 2 0 2.3 1.8 12/11/2005 05:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 317 0 165 165 2 0 2.3 1.8 12/11/2005 05:50:00 0.4 0.1 1.1 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 285 16 317 165 1.9 0 2.1 1.8 12/11/2005 06:00:00 1 0.7 2.6 0.4 0.8 0.6 2.6 0.4 0.5 0.3 1.9 0.4 284 12 279 165 1.9 0 2.1 1.8 12/11/2005 06:10:00 2.1 1.2 5.3 0.4 2.1 1.3 4.9 0.4 1.7 1.1 3.8 0.4 283 19 297 165 2 0 2.3 1.8 12/11/2005 06:20:00 3.6 0.8 5.3 1.9 3.5 0.8 5.3 1.9 2.9 0.7 4.6 1.1 291 9 292 165 2.1 0 2.3 1.8 12/11/2005 06:30:00 3.8 0.6 5.7 2.6 3.7 0.6 5.7 2.3 2.7 0.6 4.6 1.1 300 6 302 165 2.3 0 2.3 2.1 12/11/2005 06:40:00 3.3 0.4 4.6 2.6 3.3 0.4 4.6 2.3 2.5 0.5 3.8 1.5 293 6 304 165 2.2 0 2.3 2.1 12/11/2005 06:50:00 2.7 0.6 4.2 0.7 2.5 0.7 3.8 0.4 2 0.7 3.8 0.4 298 11 299 165 2.3 0 2.6 2.3 12/11/2005 07:00:00 2.4 0.4 3.4 1.5 2.2 0.5 3.4 1.1 1.8 0.5 3 0.7 305 9 305 165 2.2 0 2.3 2.1 12/11/2005 07:10:00 2.5 0.6 4.2 1.5 2.4 0.5 3.8 1.1 1.8 0.6 3.4 0.7 305 6 312 165 2.2 0 2.3 2.1 12/11/2005 07:20:00 3.5 0.6 5.3 1.9 3.4 0.6 5.3 1.9 3.3 0.6 4.9 1.5 319 9 307 165 2.3 0 2.3 2.1 12/11/2005 07:30:00 3 0.6 4.9 1.1 2.6 0.7 4.2 0.4 2.7 0.6 4.6 0.7 326 17 349 165 2.3 0 2.6 2.3 12/11/2005 07:40:00 3.3 0.6 4.9 1.5 3 0.8 4.6 0.7 2.7 0.6 4.2 1.5 314 22 284 165 2.2 0 2.3 2.1 12/11/2005 07:50:00 4.3 0.8 6.5 2.3 4.2 0.8 6.1 2.3 3.4 0.8 5.3 1.9 300 10 301 165 2.1 0 2.3 2.1 12/11/2005 08:00:00 5.6 0.8 8 3.8 5.5 0.8 7.6 3.4 4.7 1 6.8 2.6 307 13 313 165 2.1 0 2.3 1.8 12/11/2005 08:10:00 6.5 1 8.8 4.2 6.4 1 8.4 3.8 6.1 1 8.8 3.4 316 9 318 165 2 0.1 2.3 1.8 12/11/2005 08:20:00 7.1 1 9.1 4.6 6.9 1 9.1 4.6 6.8 1.1 9.1 4.2 320 9 311 165 1.8 0 1.8 1.6 12/11/2005 08:30:00 7.1 1.1 9.5 3.8 7 1.1 9.1 4.2 6.7 1.4 9.5 2.6 317 10 328 165 1.8 0 1.8 1.6 12/11/2005 08:40:00 6.9 1.2 9.1 3.4 6.8 1.2 9.5 3.8 5.6 1.1 8.4 2.6 307 8 302 165 1.7 0 1.8 1.6 12/11/2005 08:50:00 7.3 1.5 11.1 4.9 7.3 1.5 10.7 4.2 6.5 1.6 10.3 3.4 312 8 319 165 1.7 0 1.8 1.6 12/11/2005 09:00:00 11.2 1.2 14.1 8.8 11.1 1.2 13.7 8.4 10.4 1.1 13 7.2 314 5 313 165 1.5 0 1.8 1.4 12/11/2005 09:10:00 12 1.5 15.3 8.8 11.9 1.5 15.3 8.8 11 1.2 14.5 8 318 1 318 165 1.4 0 1.6 1.4 12/11/2005 09:20:00 14.8 1 16.8 10.3 14.8 1 16.8 9.9 13.2 1.2 17.2 9.5 317 0 317 165 1.6 0 1.8 1.6 12/11/2005 09:30:00 14.2 1 17.2 11.8 14.2 1.1 16.8 11.8 12.6 1 15.3 10.3 317 0 317 165 1.3 0.1 1.6 1.1 12/11/2005 09:40:00 13.1 1.2 16.1 9.5 13.1 1.2 16.1 9.5 12.3 1.5 16.8 9.1 318 0 318 165 1.2 0 1.4 1.1 12/11/2005 09:50:00 13.8 1.5 16.8 9.5 13.7 1.5 17.2 9.5 12.4 1.5 16.4 8.4 317 0 317 165 1.1 0 1.4 0.9 12/11/2005 10:00:00 14.6 1.1 16.8 10.7 14.6 1.1 16.8 11.1 12.6 1 14.9 8.8 317 0 317 165 1.1 0 1.4 1.1 12/11/2005 10:10:00 13.4 1 15.3 10.7 13.4 1 15.6 9.9 11.6 1.2 15.3 8.8 317 0 317 165 1.2 0 1.4 0.9 12/11/2005 10:20:00 13.4 1 15.3 10.3 13.4 1 15.3 10.3 11.2 1 13.7 7.6 316 0 316 165 1.2 0 1.4 1.1 12/11/2005 10:30:00 12.9 1.3 16.4 9.1 12.9 1.3 16.8 9.5 10.9 1.3 14.5 7.6 312 5 316 165 1.4 0 1.6 1.4 12/11/2005 10:40:00 11.7 1.3 14.9 8.8 11.7 1.3 15.3 8.8 9.2 1.4 13.3 6.5 300 5 300 165 1.4 0 1.6 1.1 12/11/2005 10:50:00 11.3 1.1 14.1 8.4 11.3 1 13.7 8.4 9 1.4 13 6.1 296 4 291 165 1.3 0 1.4 1.4 12/11/2005 11:00:00 12.2 1 14.9 8 12.2 1 14.9 8 9.7 1.5 13.3 5.7 294 3 296 165 1.3 0 1.4 1.4 12/11/2005 11:10:00 13 1.4 15.6 8.8 13 1.4 15.6 9.1 10.7 1.7 15.6 6.5 292 3 291 165 1.1 0 1.4 0.9 12/11/2005 11:20:00 11.7 1.3 14.9 7.6 11.8 1.3 14.9 7.6 10.6 1.8 14.5 5.7 290 2 291 165 0.9 0 1.1 0.9 12/11/2005 11:30:00 11.6 1 14.1 7.6 11.6 1 14.1 8 8.9 1.2 13.7 5.7 299 5 301 165 0.8 0 1.1 0.9 12/11/2005 11:40:00 11.3 0.9 13.3 9.1 11.3 0.8 13.3 9.1 8.7 1.1 11.1 5.7 302 3 302 165 0.7 0 0.9 0.7 12/11/2005 11:50:00 9.4 1.7 13.3 4.9 9.4 1.7 13 4.9 7.7 1.7 13.3 3.8 296 4 293 165 0.5 0 0.7 0.4 12/11/2005 12:00:00 12.3 1.3 15.3 8.4 12.4 1.3 15.3 8.4 11.2 2.1 16.8 6.1 289 3 286 165 0.4 0 0.7 0.2 12/11/2005 12:10:00 14.3 1 17.2 10.7 14.3 1 17.2 11.1 11.3 1.5 15.6 7.6 298 6 301 165 0.3 0 0.7 0.2 12/11/2005 12:20:00 14.6 1 16.8 11.1 14.5 1 16.8 11.5 11.3 1.2 14.5 8.4 303 3 302 165 0.4 0 0.7 0.2 12/11/2005 12:30:00 14.4 1.1 17.6 11.1 14.4 1.1 17.6 11.1 11.9 1.4 15.6 8.4 305 4 304 165 0.5 0 0.7 0.2 12/11/2005 12:40:00 13.8 0.9 15.6 11.5 13.7 0.9 15.6 11.5 12.4 1.2 15.6 9.5 309 3 305 165 0.4 0 0.7 0.2 12/11/2005 12:50:00 14.5 1.1 16.4 11.5 14.5 1 16.4 11.5 13 1.4 17.2 9.5 309 4 304 165 0.2 0 0.4 0.2 12/11/2005 13:00:00 14.3 1.2 16.8 10.3 14.3 1.2 16.8 10.3 11.9 1.5 15.6 7.6 306 4 297 165 0.1 0 0.2 -0.1 12/11/2005 13:10:00 15.1 1 17.6 11.8 15.1 1 17.2 11.8 13.7 1.2 17.2 9.9 309 3 312 165 0.1 0 0.2 -0.1 12/11/2005 13:20:00 14.6 1.5 17.2 11.1 14.6 1.5 17.6 11.1 13 1.7 16.8 7.6 308 4 309 165 -0.1 0 0.2 -0.1 12/11/2005 13:30:00 14.2 1.6 16.8 9.5 14.2 1.5 17.2 9.9 12.5 1.7 16.8 8 309 5 310 165 -0.1 0 0.2 -0.1 12/11/2005 13:40:00 14.8 1.3 17.6 11.1 14.8 1.3 17.6 11.1 13 1.5 16.4 8.4 309 4 310 165 -0.1 0 0.2 -0.1 12/11/2005 13:50:00 13.3 1.5 16.4 9.1 13.3 1.5 16.4 9.5 11.9 1.5 15.3 8.4 309 6 310 165 -0.1 0 0.2 -0.3 12/11/2005 14:00:00 12.7 1.5 16.4 9.1 12.7 1.5 16.4 9.1 11.3 1.9 16.1 6.5 310 6 305 165 -0.3 0 -0.1 -0.3 12/11/2005 14:10:00 12.9 1.4 16.4 9.9 12.9 1.4 16.4 9.9 10.3 1.5 14.5 6.8 306 5 305 165 -0.3 0 -0.1 -0.3 12/11/2005 14:20:00 12.4 1.3 16.1 9.1 12.4 1.2 16.4 9.1 10 1.5 13.7 6.8 305 5 307 165 -0.3 0 -0.1 -0.3 12/11/2005 14:30:00 12.4 1.3 15.6 8.8 12.4 1.3 15.6 9.5 9.3 1.2 13.3 6.5 302 6 301 165 -0.3 0 -0.1 -0.3 12/11/2005 14:40:00 11.6 1.3 14.5 8.4 11.6 1.3 14.5 8.4 9.1 1.3 13.3 6.5 303 5 310 165 -0.3 0 -0.3 -0.5 12/11/2005 14:50:00 11.3 1.2 14.5 8 11.3 1.2 14.5 8 8.9 1.1 12.2 6.1 304 6 300 165 -0.4 0 -0.3 -0.5 12/11/2005 15:00:00 12.2 1.5 16.4 8.8 12.2 1.4 16.4 8.4 9.4 1.3 13.3 6.1 303 6 297 165 -0.6 0 -0.3 -0.8 12/11/2005 15:10:00 13.6 1.5 16.8 10.3 13.6 1.5 16.8 10.3 10.7 1.5 15.3 7.6 304 6 307 165 -0.8 0.1 -0.5 -1 12/11/2005 15:20:00 13.7 1.5 17.2 10.7 13.7 1.5 17.2 10.3 10.7 1.4 14.9 7.2 305 5 301 165 -0.9 0 -0.8 -1.2 12/11/2005 15:30:00 13.3 1.7 16.1 9.1 13.3 1.7 16.4 8.8 9.8 1.2 13 6.5 302 6 302 165 -1 0 -0.8 -1.2 12/11/2005 15:40:00 12.9 1.2 15.6 9.9 12.9 1.2 16.1 9.5 10 1.1 13.7 6.8 304 5 306 165 -0.9 0 -0.8 -1 12/11/2005 15:50:00 13.7 1.1 15.6 9.9 13.7 1.1 15.6 9.9 10 1.1 13.3 7.2 303 4 305 165 -0.9 0 -0.8 -1.2 12/11/2005 16:00:00 13.5 1 16.4 10.7 13.6 1 16.4 11.1 10.2 1.4 14.5 6.8 304 5 305 165 -1 0 -0.8 -1.2 12/11/2005 16:10:00 13.3 1.3 16.4 9.1 13.3 1.3 16.1 9.5 10.5 1.3 14.1 6.8 305 5 305 165 -1.2 0.1 -0.8 -1.4 12/11/2005 16:20:00 15 1.3 17.6 10.3 15 1.3 17.6 10.7 11.2 1.4 16.1 8 304 5 305 165 -1.4 0 -1.2 -1.4 12/11/2005 16:30:00 15 1.1 17.6 11.8 14.9 1.1 17.6 11.5 11.6 1.5 16.4 8.4 305 5 303 165 -1.6 0 -1.4 -1.7 12/11/2005 16:40:00 15.1 1.7 18.7 11.1 15.1 1.7 18.3 11.5 11.3 1.4 16.8 8.4 301 5 304 165 -1.7 0 -1.4 -1.9 12/11/2005 16:50:00 15.8 1.3 17.9 11.1 15.8 1.3 17.9 11.1 11.9 1.4 16.1 8.4 304 4 303 165 -1.8 0 -1.7 -1.9 12/11/2005 17:00:00 14.8 1.2 17.6 11.5 14.8 1.2 17.6 11.5 12 1.5 16.8 9.1 306 5 303 165 -1.9 0 -1.7 -1.9 12/11/2005 17:10:00 14.9 1.4 17.9 10.7 14.9 1.4 18.3 11.1 12 1.5 15.6 8.8 305 5 305 165 -2 0 -1.7 -1.9 12/11/2005 17:20:00 15.3 1.3 17.9 10.7 15.4 1.4 17.9 10.7 11.1 1.2 14.9 8 303 4 304 165 -1.8 0 -1.7 -1.9 12/11/2005 17:30:00 14.3 1 17.2 11.1 14.3 1 17.6 11.1 10.4 1.2 14.5 7.6 302 6 302 165 -1.8 0 -1.7 -1.9 12/11/2005 17:40:00 14.1 1.3 17.9 10.7 14.2 1.3 17.6 10.7 11.2 1.5 16.1 7.6 305 5 305 165 -2 0.1 -1.7 -2.1 12/11/2005 17:50:00 14.5 1.3 17.6 11.1 14.6 1.3 17.2 11.1 11.3 1.4 15.3 8.4 305 5 302 165 -2.1 0 -1.9 -2.1 12/11/2005 18:00:00 14.8 1.1 16.8 11.1 14.8 1.1 17.2 11.1 11.2 1.5 15.6 7.2 305 4 302 165 -2.2 0 -2.1 -2.4 12/11/2005 18:10:00 13.8 1.1 16.4 10.3 13.8 1.1 16.8 9.5 11.9 1.6 15.6 8 308 5 309 165 -2.4 0 -2.1 -2.6 12/11/2005 18:20:00 12.8 0.9 14.5 10.3 12.8 0.9 14.5 9.9 11.8 1.2 14.5 8.4 311 4 318 165 -2.4 0 -2.1 -2.6 12/11/2005 18:30:00 13.8 1 16.1 11.8 13.8 1 16.1 11.5 13.3 1 16.1 9.9 314 4 306 165 -2.5 0 -2.4 -2.6 12/11/2005 18:40:00 14 1.2 16.4 10.7 13.9 1.2 16.4 10.3 13.1 1.5 16.8 9.1 312 5 317 165 -2.5 0 -2.6 -2.6 12/11/2005 18:50:00 13.5 1.1 16.1 10.7 13.4 1.1 16.1 10.7 10.6 1.5 14.1 7.2 305 5 302 165 -2.6 0 -2.6 -2.8 12/11/2005 19:00:00 12.5 1 15.3 9.5 12.5 1 15.3 9.5 9.7 1.1 13.7 6.8 304 5 298 165 -2.6 0 -2.6 -2.8 12/11/2005 19:10:00 10.9 1 14.5 8 10.9 1 14.9 8 9.4 1.4 13.7 6.1 309 6 300 165 -2.8 0 -2.6 -2.8 12/11/2005 19:20:00 11.1 1.2 13.7 8 11.1 1.3 13.7 7.6 9.5 1.2 13 6.5 308 5 301 165 -2.8 0 -2.6 -2.8 12/11/2005 19:30:00 13.3 1.6 16.4 9.1 13.2 1.6 16.1 8.8 10.9 1.4 14.1 7.6 308 5 301 165 -2.9 0 -2.8 -3 12/11/2005 19:40:00 12.8 1.3 16.4 9.9 12.8 1.3 16.4 9.9 10.3 1.8 14.9 5.7 305 7 318 165 -2.9 0 -2.8 -3 12/11/2005 19:50:00 12.4 1.1 14.9 9.1 12.3 1.1 14.9 9.1 9.6 1.3 13.3 6.5 303 6 300 165 -3 0 -2.8 -3 12/11/2005 20:00:00 13 1.3 16.4 9.9 12.9 1.3 16.4 9.9 10 1.2 13.3 6.5 300 6 295 165 -3.2 0 -2.8 -3.3 12/11/2005 20:10:00 12.2 1.1 14.9 8.4 12.1 1.1 14.5 8.8 9.5 1.1 12.2 6.5 295 5 298 165 -3.4 0.1 -3 -3.5 12/11/2005 20:20:00 11.4 1.4 14.9 5.7 11.3 1.4 14.1 6.1 8.8 1.2 11.5 4.9 298 6 304 165 -3.6 0 -3.3 -3.7 12/11/2005 20:30:00 9.2 1.3 12.6 5.3 9.1 1.3 12.2 4.9 7.1 1.5 10.7 3.4 295 9 295 165 -3.8 0 -3.5 -4.2 12/11/2005 20:40:00 9.9 1.9 14.1 4.6 9.7 1.7 13.7 4.6 7.5 2 12.2 1.9 293 9 298 165 -3.8 0.1 -3.5 -4.2 12/11/2005 20:50:00 9.2 2.3 13.3 3 9.1 2.2 13 2.6 6.9 2.2 11.8 0.7 299 10 291 165 -3.9 0 -3.5 -3.9 12/11/2005 21:00:00 6.1 1.5 9.9 1.9 6 1.5 9.5 2.3 4.4 1.3 8 0.7 303 21 305 165 -4 0 -3.7 -4.2 12/11/2005 21:10:00 9.7 1.7 13.3 4.9 9.6 1.7 13.3 5.3 7.9 1.7 11.8 3.8 306 9 302 165 -4.2 0 -3.9 -4.4 12/11/2005 21:20:00 9.5 1.8 13.3 5.7 9.4 1.8 13.3 4.9 7.7 1.7 11.5 3.4 305 8 302 165 -4.3 0 -3.9 -4.4 12/11/2005 21:30:00 7 1.7 11.8 2.3 7 1.7 11.5 2.6 5.7 1.6 9.5 2.3 308 13 301 165 -4.4 0 -4.4 -4.6 12/11/2005 21:40:00 5 1.6 9.1 0.4 4.9 1.7 8.8 0.4 3.6 1.5 8 0.4 294 23 300 165 -4.3 0 -4.2 -4.6 12/11/2005 21:50:00 3.6 0.9 5.3 0.4 3.9 1.2 6.5 0.7 3.2 1.2 6.1 0.4 272 20 285 165 -4.3 0 -4.2 -4.4 12/11/2005 22:00:00 3.8 1.2 6.5 1.5 4.3 1.1 7.6 1.5 4.1 1.1 7.2 1.9 262 12 259 165 -4.1 0.1 -3.7 -4.4 12/11/2005 22:10:00 5.7 1.4 8.8 2.3 6.6 1.2 9.5 3.4 6.3 1.2 9.1 3.8 268 10 273 165 -3.9 0 -3.9 -4.2 12/11/2005 22:20:00 5.6 0.6 7.6 4.2 5.7 0.6 7.6 4.2 5.1 0.9 6.8 2.6 285 10 289 165 -4.2 0.1 -3.7 -4.4 12/11/2005 22:30:00 6.6 0.6 8.4 4.6 6.6 0.6 8.4 4.6 5.1 0.7 7.2 3.8 299 7 297 165 -3.9 0 -3.7 -4.4 12/11/2005 22:40:00 6.1 0.8 8.8 4.2 6.1 0.8 8.4 4.2 5 0.8 7.2 3 305 8 309 165 -4.1 0.1 -3.9 -4.4 12/11/2005 22:50:00 4.2 0.8 6.5 2.3 4.2 0.8 6.5 2.3 3.7 1 5.7 1.1 306 15 316 165 -4.3 0 -3.9 -4.6 12/11/2005 23:00:00 5.3 0.8 7.6 3.4 5.6 0.9 8 3.8 5 1 7.6 2.6 282 10 274 165 -4.3 0.1 -3.9 -4.6 12/11/2005 23:10:00 6.2 1.4 9.5 3 6.3 1.3 9.5 3 5.5 1.1 9.1 2.3 287 11 292 165 -4 0 -3.7 -4.4 12/11/2005 23:20:00 4.9 1 7.2 2.3 4.9 1 7.2 2.6 3.9 0.8 6.1 2.3 294 11 307 165 -3.9 0.2 -3.5 -4.2 12/11/2005 23:30:00 4.3 1.3 7.6 0.4 4.2 1.3 7.6 0.4 3.4 1.2 6.8 0.4 316 17 294 165 -4.3 0.1 -3.9 -4.6 12/11/2005 23:40:00 3.3 1.6 7.6 0.7 3.3 1.7 7.6 0.7 2.1 1.5 6.8 0.4 303 30 273 165 -4.8 0 -4.4 -5 12/11/2005 23:50:00 5.5 1.3 8.8 2.6 5.5 1.2 8.4 2.6 4.5 1.1 7.6 2.3 306 13 295 165 -4.3 0.1 -3.9 -4.6 12/12/2005 00:00:00 6.5 1 8.8 4.6 6.5 1 8.8 4.6 5.1 1 8 1.9 299 7 291 165 -4.5 0 -4.4 -4.6 12/12/2005 00:10:00 9.9 1.9 13.7 5.7 9.9 1.9 13.7 5.3 7.9 1.7 12.6 3.8 296 7 296 165 -4.2 0.2 -3.9 -4.6 12/12/2005 00:20:00 11.3 1.5 14.9 7.6 11.3 1.6 14.9 7.6 9.4 2 14.9 5.3 291 7 282 165 -4.2 0.1 -3.9 -4.4 12/12/2005 00:30:00 10.5 1 14.1 8 10.6 1 14.5 8 8.6 1.8 13.7 5.7 291 8 277 165 -4.4 0 -4.4 -4.6 12/12/2005 00:40:00 12.1 1.8 16.1 7.6 12.2 1.8 16.1 7.2 9.9 2.2 16.1 5.7 292 6 294 165 -4.4 0 -4.2 -4.6 12/12/2005 00:50:00 15.4 1.2 18.3 12.2 15.5 1.2 18.7 12.2 13.3 2.3 19.1 8.8 289 6 285 165 -4.3 0 -4.2 -4.4 12/12/2005 01:00:00 16.9 1.3 21.8 12.6 16.9 1.3 21.4 13 13.2 2 21 8.8 294 5 296 165 -4.3 0.1 -3.9 -4.6 12/12/2005 01:10:00 17.2 1.8 21 12.2 17.2 1.8 21.4 12.2 13 1.9 18.7 8.4 299 6 298 165 -4.2 0 -3.9 -4.4 12/12/2005 01:20:00 18.7 1.5 22.6 14.9 18.7 1.5 22.9 14.1 14.2 2 19.9 9.9 298 5 300 165 -4.4 0 -4.2 -4.6 12/12/2005 01:30:00 14.8 2.4 18.7 9.1 14.8 2.4 19.1 9.1 11 1.8 16.8 6.5 300 6 300 165 -4.5 0 -4.4 -4.6 12/12/2005 01:40:00 12.3 1.7 17.6 8.8 12.3 1.7 17.6 8.4 10 1.9 16.1 6.1 296 8 287 165 -4.7 0 -4.6 -4.6 12/12/2005 01:50:00 11.4 2.7 19.1 6.8 11.4 2.7 18.7 6.8 9.4 2.2 15.3 5.3 294 8 300 165 -4.7 0 -4.4 -4.6 12/12/2005 02:00:00 10.8 2.1 15.6 6.1 10.8 2.1 15.6 5.3 9.4 2.1 15.6 4.6 301 15 304 165 -4.6 0 -4.4 -4.6 12/12/2005 02:10:00 9.5 2 16.4 5.3 9.4 2 16.8 5.3 8.1 2.1 16.8 4.6 305 11 317 165 -4.8 0 -4.6 -4.8 12/12/2005 02:20:00 9.2 2.3 14.9 4.9 9.2 2.3 14.5 4.6 7.9 2.1 14.1 3.8 304 11 300 165 -4.8 0 -4.6 -5 12/12/2005 02:30:00 11.3 2.1 18.3 6.8 11.3 2.1 17.9 6.5 9.8 2.1 17.2 4.9 307 11 294 165 -4.7 0 -4.4 -4.6 12/12/2005 02:40:00 13.5 2.1 19.9 8.8 13.5 2.1 19.9 8.8 11.8 2.3 19.1 6.1 308 9 299 165 -4.5 0 -4.4 -4.6 12/12/2005 02:50:00 14.8 2.1 19.9 10.7 14.8 2.2 20.2 10.7 11.9 2 17.6 7.6 300 8 289 165 -4.4 0 -4.2 -4.6 12/12/2005 03:00:00 15.6 1.7 19.1 10.7 15.6 1.7 19.9 10.7 11.9 1.7 17.6 8 295 7 293 165 -4.2 0 -3.9 -4.4 12/12/2005 03:10:00 12.8 1.4 16.4 8.4 12.8 1.4 16.4 8.4 10.1 1.5 14.9 5.7 298 7 305 165 -4.2 0 -4.2 -4.4 12/12/2005 03:20:00 11.5 2 16.1 6.5 11.4 2 16.1 6.8 9.5 2.2 15.6 5.3 293 9 289 165 -4.2 0 -3.9 -4.4 12/12/2005 03:30:00 11.3 1.7 15.3 6.5 11.3 1.7 15.6 6.8 9.7 1.7 13.7 4.9 289 9 288 165 -3.9 0 -3.7 -4.2 12/12/2005 03:40:00 11.3 1.7 15.6 7.6 11.3 1.7 15.6 8 9.4 1.7 14.1 5.3 294 8 295 165 -3.7 0 -3.5 -3.9 12/12/2005 03:50:00 10.1 2.6 15.3 4.2 10.1 2.7 15.6 3.8 8.5 2.4 14.5 3.8 297 13 297 165 -3.7 0 -3.5 -3.9 12/12/2005 04:00:00 9.9 2.2 17.2 5.7 9.9 2.2 16.1 5.7 8.1 1.9 14.1 4.2 300 12 297 165 -3.6 0 -3.5 -3.9 12/12/2005 04:10:00 10.7 2 16.1 4.9 10.7 1.9 16.1 5.7 9.2 1.8 15.6 5.3 303 11 292 165 -3.7 0.1 -3.5 -3.9 12/12/2005 04:20:00 11.4 1.8 16.1 6.8 11.5 1.8 16.1 6.8 9 1.5 13 4.9 299 8 290 165 -3.6 0 -3.5 -3.7 12/12/2005 04:30:00 13.7 1.6 18.3 8.8 13.7 1.6 18.3 9.1 10.6 1.4 15.6 6.8 298 7 293 165 -3.5 0 -3.5 -3.5 12/12/2005 04:40:00 12.3 1.5 17.2 8.4 12.2 1.6 16.8 8.8 10.2 1.4 15.6 6.5 303 9 306 165 -3.6 0 -3.3 -3.7 12/12/2005 04:50:00 12.5 1.5 17.6 9.1 12.4 1.5 17.2 9.1 9.9 1.7 14.9 6.5 300 7 298 165 -3.5 0 -3.3 -3.5 12/12/2005 05:00:00 13 2.2 18.7 7.6 13 2.2 19.1 6.8 10.5 2.1 18.3 4.6 299 9 304 165 -3.5 0 -3.3 -3.5 12/12/2005 05:10:00 11.5 2 16.8 7.2 11.5 2 16.4 7.2 9.8 2 16.4 5.7 302 12 292 165 -3.5 0 -3.3 -3.5 12/12/2005 05:20:00 12.7 1.9 16.4 6.8 12.7 2 16.8 8 10.8 2.3 16.4 5.7 293 11 284 165 -3.2 0.1 -3 -3.5 12/12/2005 05:30:00 10 1.7 14.9 5.7 10 1.7 14.9 5.7 8 1.5 11.8 4.6 297 11 301 165 -3.2 0.1 -3 -3.3 12/12/2005 05:40:00 12.2 2.1 17.6 7.2 12.2 2.2 17.2 7.2 10.5 2.6 17.2 4.9 293 10 276 165 -2.9 0 -2.6 -3.3 12/12/2005 05:50:00 12.8 1.7 17.2 6.8 12.8 1.7 17.2 6.5 10.1 1.7 16.8 6.1 293 7 287 165 -2.9 0 -2.6 -3 12/12/2005 06:00:00 13 1.6 17.9 8.4 13 1.6 17.9 8.4 9.8 1.5 14.1 6.5 300 7 282 165 -3 0 -2.8 -3 12/12/2005 06:10:00 13 1.7 17.9 8.8 13 1.7 17.9 9.1 10.4 2 16.8 6.5 296 8 287 165 -2.6 0.1 -2.6 -2.8 12/12/2005 06:20:00 12.5 1.2 15.6 9.5 12.6 1.2 16.1 9.1 10.5 1.7 15.6 6.8 290 6 300 165 -2.4 0.1 -1.9 -2.8 12/12/2005 06:30:00 13.1 1.9 16.8 9.5 13.2 1.9 16.8 9.1 11.6 2.4 17.2 6.5 288 7 281 165 -2.2 0 -2.1 -2.4 12/12/2005 06:40:00 14.9 1.6 19.9 10.7 14.9 1.6 19.9 10.7 12.4 2 18.3 8 290 6 284 165 -2.1 0 -1.9 -2.4 12/12/2005 06:50:00 16.8 1.7 20.6 11.5 16.8 1.7 20.6 10.7 12.8 1.9 20.2 8.4 294 6 289 165 -2 0 -1.9 -2.1 12/12/2005 07:00:00 16.7 2.2 22.1 11.1 16.7 2.3 21.8 10.3 12.6 1.9 18.3 8.8 297 7 299 165 -2 0 -1.9 -2.1 12/12/2005 07:10:00 18.3 1.9 23.7 13.3 18.3 1.9 23.3 14.1 14 2.1 21 9.1 298 7 300 165 -1.9 0 -1.7 -1.9 12/12/2005 07:20:00 17.3 1.8 21.8 12.6 17.3 1.9 22.1 13.3 13.1 1.7 17.9 9.1 298 6 294 165 -2 0 -1.7 -2.1 12/12/2005 07:30:00 16.3 1.5 19.9 11.1 16.3 1.5 20.6 11.1 12.7 1.9 18.7 8.4 297 7 293 165 -2 0 -1.7 -2.1 12/12/2005 07:40:00 17.4 1.5 21.4 11.8 17.3 1.7 21.8 11.5 13.4 2 20.6 9.5 297 6 287 165 -2 0 -1.9 -2.1 12/12/2005 07:50:00 16.3 1.3 20.2 12.2 16.3 1.5 19.9 12.2 12.9 1.9 20.2 9.1 294 6 288 165 -2 0 -1.7 -2.1 12/12/2005 08:00:00 17.2 1.5 21.8 13.3 17.2 1.6 21.8 13 13.1 2 19.1 9.1 295 6 296 165 -2 0 -1.9 -2.1 12/12/2005 08:10:00 15.4 1.1 18.7 13 15.4 1.2 18.7 13 12.3 1.7 16.8 8.4 292 5 286 165 -2 0 -1.9 -2.1 12/12/2005 08:20:00 14.1 1 16.8 11.8 14.1 1 17.2 11.8 11 1.4 15.3 8 293 5 295 165 -2 0 -1.9 -2.1 12/12/2005 08:30:00 15.5 1.2 18.7 12.2 15.6 1.3 18.7 11.8 12.3 1.8 18.7 8 293 5 290 165 -2 0 -1.9 -2.1 12/12/2005 08:40:00 17.4 1.3 21 14.5 17.5 1.4 21 14.1 13.4 2.3 20.6 9.5 294 5 293 165 -1.8 0 -1.7 -1.9 12/12/2005 08:50:00 15.8 1.3 18.7 13 15.8 1.3 18.7 13 11.5 1.5 16.4 8 298 5 302 165 -2 0 -1.7 -2.1 12/12/2005 09:00:00 14.5 1.1 17.2 11.8 14.5 1.1 17.6 12.2 11.6 2 16.8 8 294 5 290 165 -1.8 0 -1.7 -1.9 12/12/2005 09:10:00 14 1.7 18.7 10.3 14.1 1.7 18.7 9.9 11.8 2 17.6 7.6 290 5 285 165 -1.8 0 -1.7 -1.9 12/12/2005 09:20:00 14.6 1.5 17.6 10.7 14.6 1.5 17.6 10.7 10.9 1.5 16.8 8 294 5 291 165 -1.7 0 -1.4 -1.9 12/12/2005 09:30:00 14.8 1.2 17.6 11.1 14.8 1.2 17.6 11.5 12 1.6 17.9 8.4 291 5 289 165 -1.7 0 -1.4 -1.9 12/12/2005 09:40:00 13.8 1.1 16.4 10.3 13.8 1.1 16.4 10.7 11.6 1.8 16.4 8 290 6 282 165 -1.9 0 -1.7 -2.1 12/12/2005 09:50:00 12.5 1.8 16.4 8 12.4 1.8 16.4 8 9.9 1.7 15.6 6.1 294 6 291 165 -1.9 0 -1.4 -2.1 12/12/2005 10:00:00 11.6 1 14.5 8.8 11.6 1.1 14.1 8.8 9.7 1.4 13.3 5.7 290 6 298 165 -1.8 0.1 -1.4 -1.9 12/12/2005 10:10:00 10.7 0.9 13 8 10.7 1 13 7.6 8.5 1.3 12.6 5.7 294 7 290 165 -1.9 0 -1.9 -2.1 12/12/2005 10:20:00 11.3 1 13.7 8 11.3 1.1 13.7 8.4 9.3 1.5 14.1 5.7 291 6 285 165 -1.8 0 -1.7 -1.9 12/12/2005 10:30:00 10.8 1.2 13.3 6.5 10.8 1.2 13.7 6.5 8.4 1.3 13 4.9 294 6 289 165 -1.7 0 -1.7 -1.9 12/12/2005 10:40:00 11.4 1.3 15.3 7.6 11.4 1.3 15.3 7.2 9.5 2 15.3 5.3 289 7 292 165 -1.7 0 -1.4 -1.9 12/12/2005 10:50:00 10.9 1.4 13.7 7.2 10.9 1.5 13.7 6.8 9.5 1.7 13 4.9 287 6 297 165 -1.6 0 -1.4 -1.7 12/12/2005 11:00:00 10.9 1.2 13.3 6.8 11 1.2 13.3 6.8 9.9 1.6 13.7 4.9 285 7 281 165 -1.4 0 -1.2 -1.4 12/12/2005 11:10:00 10.1 1.2 12.2 6.8 10.1 1.2 12.2 6.8 8.3 1.5 11.8 4.9 291 5 301 165 -1.2 0 -1 -1.4 12/12/2005 11:20:00 9.6 0.9 11.5 7.2 9.5 1 11.8 6.5 7.6 1.1 11.1 5.3 293 6 297 165 -1 0 -0.8 -1.2 12/12/2005 11:30:00 10.4 1 13 6.8 10.4 1 13 6.8 8 1.2 11.8 5.3 293 5 284 165 -1.1 0 -0.8 -1.2 12/12/2005 11:40:00 10.8 0.8 13.3 8.4 10.8 0.8 13.3 8 8.5 1.2 11.8 5.7 291 5 294 165 -1.1 0 -1 -1.2 12/12/2005 11:50:00 10.4 1.3 13 7.6 10.4 1.3 13.3 7.6 7.9 1.2 11.5 5.3 297 6 296 165 -1 0 -0.8 -1.2 12/12/2005 12:00:00 7.7 1 9.9 5.7 7.6 1 10.3 5.3 6.1 0.8 8.8 3.8 303 7 300 165 -0.9 0 -0.8 -1.2 12/12/2005 12:10:00 8.1 1.3 11.5 5.3 8.1 1.3 11.5 5.3 6.7 1 9.5 3.4 303 9 293 165 -0.8 0 -0.5 -0.8 12/12/2005 12:20:00 9.8 1 11.8 6.8 9.7 1 11.8 7.2 7.7 0.9 9.9 5.3 298 6 285 165 -0.6 0 -0.5 -0.8 12/12/2005 12:30:00 9.9 0.8 12.2 7.6 9.8 0.8 11.8 7.6 7.9 0.9 9.9 5.7 296 5 302 165 -0.5 0 -0.3 -0.8 12/12/2005 12:40:00 9.9 1 12.2 7.2 9.8 1 12.2 7.2 7.8 1 10.3 4.9 304 6 302 165 -0.7 0 -0.5 -0.8 12/12/2005 12:50:00 9.9 1 12.6 7.2 9.8 1 12.6 7.2 7.6 1 10.7 4.9 301 6 307 165 -0.6 0 -0.5 -0.8 12/12/2005 13:00:00 9.5 0.8 11.5 7.6 9.5 0.8 11.5 7.2 7 0.8 9.9 5.3 299 5 296 165 -0.8 0 -0.5 -0.8 12/12/2005 13:10:00 9.8 0.9 12.2 6.8 9.8 0.9 11.8 6.8 7.3 0.8 9.5 5.3 299 4 304 165 -0.9 0 -0.5 -0.8 12/12/2005 13:20:00 9.2 0.9 11.1 6.1 9.2 0.9 11.5 5.7 7 0.9 10.7 4.9 298 5 289 165 -0.9 0 -0.8 -0.8 12/12/2005 13:30:00 9.6 1 12.2 7.2 9.6 1 11.8 7.2 7.5 1 11.5 4.9 295 6 291 165 -0.8 0 -0.5 -0.8 12/12/2005 13:40:00 10.2 0.8 11.8 7.2 10.2 0.8 12.2 7.2 8 1 11.1 5.3 294 4 293 165 -0.6 0 -0.5 -0.8 12/12/2005 13:50:00 9.6 0.5 11.1 8 9.7 0.5 11.5 8.4 8.2 0.9 11.5 6.5 291 4 292 165 -0.8 0 -0.5 -0.8 12/12/2005 14:00:00 10.1 0.6 11.5 8.8 10.1 0.6 11.8 8.4 7.3 0.9 10.3 5.3 299 5 291 165 -0.9 0 -0.8 -1 12/12/2005 14:10:00 10 0.5 11.5 8.8 10 0.6 11.8 8.4 7 0.9 10.3 5.3 300 3 307 165 -0.9 0 -0.8 -1.2 12/12/2005 14:20:00 11.3 0.5 12.6 9.1 11.3 0.6 12.6 9.5 7.9 0.9 11.5 6.1 301 4 302 165 -0.9 0 -0.5 -1 12/12/2005 14:30:00 12.2 0.7 14.5 10.3 12.2 0.8 14.5 10.3 9.9 1.2 13 6.5 307 3 307 165 -1 0 -0.8 -1.2 12/12/2005 14:40:00 13.5 1 15.3 10.7 13.5 1 15.3 10.7 11.8 1.2 15.3 8.4 309 3 308 165 -0.9 0 -0.8 -1 12/12/2005 14:50:00 14.4 0.9 16.1 11.1 14.3 0.9 16.4 11.1 12.7 1.1 15.6 9.5 310 3 308 165 -0.8 0 -0.5 -0.8 12/12/2005 15:00:00 14.4 1 16.8 11.8 14.4 1 16.8 12.2 12.4 1.3 15.3 9.1 308 4 300 165 -0.7 0 -0.5 -0.8 12/12/2005 15:10:00 14 1 16.4 11.1 13.9 1 16.4 10.7 11.8 1.3 15.3 8.4 308 5 303 165 -0.8 0 -0.5 -0.8 12/12/2005 15:20:00 12.9 1.1 15.6 9.5 12.8 1.2 15.3 9.1 10.5 1.4 14.9 6.8 306 5 309 165 -0.7 0 -0.5 -0.8 12/12/2005 15:30:00 11.9 1 14.5 8.8 11.7 1 14.5 8.8 9.3 1 11.8 6.5 302 5 298 165 -0.6 0 -0.5 -0.8 12/12/2005 15:40:00 9.9 1.3 13 6.8 9.7 1.3 13.3 6.8 7.8 1.5 11.8 3 301 7 298 165 -0.3 0.1 -0.3 -0.5 12/12/2005 15:50:00 7.6 1.6 11.5 2.6 7.6 1.6 11.1 2.6 5.4 1.8 9.9 0.7 295 12 293 165 -0.3 0 -0.1 -0.5 12/12/2005 16:00:00 2.8 1.5 6.5 0.4 2.9 1.5 6.5 0.4 2.2 1 4.9 0.4 339 102 284 165 -0.2 0 -0.1 -0.3 12/12/2005 16:10:00 2.3 1.5 6.8 0.4 2.3 1.5 7.2 0.4 1.9 1.2 6.1 0.4 239 64 269 165 -0.2 0 0.2 -0.3 12/12/2005 16:20:00 0.6 0.5 2.6 0.4 0.7 0.5 3 0.4 0.6 0.4 1.9 0.4 197 61 296 165 -0.2 0.1 0.2 -0.3 12/12/2005 16:30:00 0.8 0.6 2.6 0.4 0.8 0.6 2.6 0.4 0.8 0.6 2.6 0.4 290 79 293 165 -0.3 0 -0.1 -0.5 12/12/2005 16:40:00 1.2 0.9 3 0.4 1.4 1 3.8 0.4 0.7 0.5 2.6 0.4 293 112 284 165 -0.3 0 -0.1 -0.5 12/12/2005 16:50:00 1.2 0.7 3 0.4 1.7 0.6 3.4 0.4 0.9 0.5 2.3 0.4 264 18 280 165 -0.5 0 -0.3 -0.5 12/12/2005 17:00:00 2.7 0.8 4.9 0.4 3.4 0.9 4.9 1.1 3 0.9 4.9 0.7 262 11 275 165 -0.5 0 -0.3 -0.8 12/12/2005 17:10:00 3 1 5.3 0.7 3.6 1.2 7.6 1.5 3.3 1 6.5 1.5 250 15 256 165 -0.5 0.1 -0.3 -0.8 12/12/2005 17:20:00 5.9 1.3 8.4 3.4 6.3 1 8.4 3.8 5.8 1.1 8.4 3 278 11 291 165 -0.2 0.1 0.2 -0.5 12/12/2005 17:30:00 7.5 0.7 9.1 5.7 7.7 0.8 9.5 5.7 7.1 1.1 9.9 4.9 282 5 278 165 0 0 0.4 -0.1 12/12/2005 17:40:00 6 0.9 7.6 3 6.7 0.6 8 5.3 6.2 0.7 7.6 3.8 273 5 278 165 0 0 0.2 -0.1 12/12/2005 17:50:00 4 0.9 6.5 1.5 4.8 1.1 7.6 2.6 4.4 1.2 7.2 1.9 253 12 269 165 0.1 0 0.2 -0.1 12/12/2005 18:00:00 2.7 0.5 4.2 1.5 2.8 0.5 4.2 1.9 2.9 0.5 4.2 2.3 195 20 229 165 0 0 0.2 -0.1 12/12/2005 18:10:00 2.1 0.5 3 1.1 2.1 0.5 3 1.1 2.4 0.5 3.4 1.1 182 15 180 165 -0.2 0.1 0.2 -0.3 12/12/2005 18:20:00 2.9 0.6 4.2 0.7 3 0.6 4.2 1.5 3 0.6 4.6 1.1 209 23 228 165 -0.1 0.1 0.2 -0.3 12/12/2005 18:30:00 2.5 0.9 4.2 0.4 2.7 0.8 4.2 0.7 2.7 0.7 4.2 1.1 138 20 119 165 -0.1 0.1 0.2 -0.3 12/12/2005 18:40:00 2.7 0.5 3.8 1.5 2.8 0.4 3.8 1.9 2.9 0.5 4.2 1.5 138 10 139 165 -0.3 0 -0.3 -0.3 12/12/2005 18:50:00 1.9 0.5 3 0.4 2.1 0.5 3 0.4 2.1 0.4 3 1.1 134 8 147 165 -0.3 0 -0.3 -0.5 12/12/2005 19:00:00 2 0.3 3 1.5 2.1 0.3 3 1.5 2.2 0.3 3 1.5 142 17 130 165 -0.4 0 -0.3 -0.5 12/12/2005 19:10:00 2.2 0.3 3 1.5 2.3 0.3 3.4 1.9 2.4 0.2 3 1.9 148 6 145 165 -0.3 0 -0.1 -0.5 12/12/2005 19:20:00 3.4 0.3 3.8 2.3 3.4 0.3 3.8 2.6 3.4 0.3 3.8 2.6 156 3 160 165 -0.3 0 -0.1 -0.5 12/12/2005 19:30:00 1.6 0.7 2.6 0.4 1.9 0.5 3 0.7 1.8 0.6 2.6 0.4 177 13 164 165 -0.2 0.1 0.2 -0.3 12/12/2005 19:40:00 1.6 0.7 2.6 0.4 1.8 0.6 2.6 0.4 1.9 0.6 2.6 0.4 180 15 176 165 0.2 0 0.4 0.2 12/12/2005 19:50:00 2.3 0.3 3 1.5 2.4 0.3 3 1.9 2.3 0.3 3 1.1 201 5 202 165 0.2 0 0.4 0.2 12/12/2005 20:00:00 2.8 0.4 3.4 1.9 2.9 0.4 3.4 1.9 2.9 0.3 3.4 2.3 216 5 220 165 0.1 0 0.2 -0.1 12/12/2005 20:10:00 2.3 0.6 3.4 1.1 2.5 0.5 3.4 1.5 2.4 0.5 3.4 1.5 215 4 215 165 0.1 0 0.2 -0.1 12/12/2005 20:20:00 2.6 0.6 3.8 1.5 2.7 0.6 3.8 1.5 2.6 0.6 3.8 1.5 218 7 227 165 0.1 0 0.2 -0.1 12/12/2005 20:30:00 2.9 0.3 3.8 2.3 3 0.3 3.8 2.3 3.2 0.3 3.8 2.3 213 4 211 165 0.2 0 0.2 -0.1 12/12/2005 20:40:00 2.5 0.4 3.4 1.1 2.5 0.4 3.4 1.1 2.8 0.4 3.4 1.5 203 7 193 165 0.3 0 0.7 0.2 12/12/2005 20:50:00 2.2 0.4 3 1.5 2.2 0.4 3 1.1 2.1 0.4 3 0.7 229 4 230 165 0.1 0 0.2 -0.1 12/12/2005 21:00:00 1.3 0.6 2.6 0.4 1.5 0.7 2.6 0.4 1.2 0.7 2.6 0.4 251 9 239 165 0.4 0 0.7 -0.1 12/12/2005 21:10:00 1.8 0.9 3.4 0.4 1.7 0.9 3.4 0.4 1.6 1 3.4 0.4 200 11 200 165 0.3 0 0.7 0.2 12/12/2005 21:20:00 1.1 0.8 3.4 0.4 1.1 0.8 3.4 0.4 1.2 0.8 3.4 0.4 192 27 203 165 0.1 0.3 0.7 -0.3 12/12/2005 21:30:00 2.5 0.6 3.4 0.4 2.5 0.6 3 0.4 2.3 0.7 3 0.4 230 5 229 165 0.1 0.2 0.4 -0.3 12/12/2005 21:40:00 2.7 0.3 3.4 1.9 2.7 0.3 3.4 1.9 2.7 0.2 3 1.9 222 7 228 165 0.2 0 0.4 0.2 12/12/2005 21:50:00 2.1 0.4 3 1.1 2.2 0.4 3 1.5 2 0.5 3 0.7 220 9 214 165 0.3 0 0.7 0.2 12/12/2005 22:00:00 1.4 0.3 2.3 0.4 1.5 0.3 2.3 0.7 1.4 0.3 2.3 0.7 234 9 222 165 0.6 0 0.7 0.7 12/12/2005 22:10:00 2.2 0.3 2.6 1.5 2.2 0.3 2.6 1.5 2 0.4 3 0.7 226 4 224 165 0.5 0 0.9 0.2 12/12/2005 22:20:00 1 0.5 2.3 0.4 1 0.5 2.3 0.4 1.1 0.4 2.3 0.4 204 13 215 165 0.4 0.1 0.9 0.2 12/12/2005 22:30:00 1.9 0.3 2.3 1.1 1.8 0.3 2.3 1.1 1.8 0.5 2.6 0.7 214 7 220 165 0.3 0 0.7 0.2 12/12/2005 22:40:00 2 0.3 2.6 1.5 2 0.3 2.6 1.5 2.1 0.3 2.6 1.1 208 3 203 165 0.7 0 0.9 0.7 12/12/2005 22:50:00 1.3 0.4 1.9 0.4 1.2 0.4 1.9 0.4 1.5 0.4 2.3 0.7 204 0 205 165 0.7 0 0.9 0.7 12/12/2005 23:00:00 1.4 0.4 1.9 0.4 1.3 0.4 1.9 0.4 1.5 0.4 2.3 0.7 209 4 213 165 0.6 0 0.9 0.7 12/12/2005 23:10:00 1.4 0.3 2.3 0.4 1.3 0.3 1.9 0.4 1.4 0.3 1.9 0.4 216 6 205 165 0.8 0 0.9 0.7 12/12/2005 23:20:00 0.7 0.3 1.5 0.4 0.5 0.3 1.1 0.4 0.6 0.4 1.5 0.4 214 6 218 165 0.8 0 0.9 0.7 12/12/2005 23:30:00 1.7 0.5 2.3 0.4 1.5 0.6 2.3 0.4 1.6 0.7 2.6 0.4 179 11 177 165 0.8 0 1.1 0.9 12/12/2005 23:40:00 2.2 0.3 2.6 1.5 2.2 0.3 2.6 1.5 2.4 0.2 3 1.9 169 6 164 165 0.8 0 1.4 0.9 12/12/2005 23:50:00 1.6 0.4 2.3 0.7 1.6 0.4 2.3 0.7 1.8 0.3 2.6 1.1 170 4 171 165 0.9 0 1.1 0.9 12/13/2005 00:00:00 0.7 0.2 1.1 0.4 0.6 0.2 1.1 0.4 0.9 0.2 1.5 0.4 166 0 166 165 1 0 1.1 0.9 12/13/2005 00:10:00 0.9 0.6 1.9 0.4 0.9 0.6 1.9 0.4 1.2 0.5 2.3 0.4 162 4 160 165 0.9 0 1.1 0.9 12/13/2005 00:20:00 1.6 0.3 1.9 0.7 1.6 0.3 1.9 0.7 1.7 0.2 2.3 1.1 143 8 154 165 0.9 0 0.9 0.9 12/13/2005 00:30:00 1.4 0.5 2.3 0.4 1.4 0.5 2.3 0.4 1.4 0.3 2.3 0.7 130 3 128 165 0.9 0 1.1 0.9 12/13/2005 00:40:00 1.2 0.7 2.3 0.4 1.1 0.7 2.3 0.4 1.5 0.5 2.6 0.7 139 2 141 165 0.7 0.2 1.1 0.2 12/13/2005 00:50:00 1.5 0.7 3.4 0.7 1.4 0.7 3.4 0.7 1.6 0.6 3 0.7 151 8 156 165 0.1 0 0.2 -0.1 12/13/2005 01:00:00 2.4 0.3 3 1.9 2.4 0.3 3 1.9 2.3 0.3 3 1.5 162 10 154 165 0.1 0 0.2 -0.1 12/13/2005 01:10:00 3.5 0.4 4.2 2.6 3.3 0.4 4.2 2.6 3.2 0.3 4.2 2.3 170 6 176 165 -0.3 0.2 0.2 -0.8 12/13/2005 01:20:00 4.1 0.5 5.3 3 3.9 0.5 4.9 3 3.8 0.5 4.9 3 166 8 156 165 -0.5 0.1 -0.1 -0.8 12/13/2005 01:30:00 3.6 0.3 4.6 2.6 3.5 0.3 4.6 3 3.5 0.3 4.6 2.6 161 5 157 165 -0.1 0 0.2 -0.3 12/13/2005 01:40:00 1.7 0.6 3.4 0.7 1.7 0.6 3 0.7 1.6 0.6 3 0.7 161 4 159 165 0.2 0 0.2 -0.1 12/13/2005 01:50:00 0.6 0.4 1.5 0.4 0.6 0.4 1.5 0.4 0.6 0.4 1.5 0.4 232 86 165 165 -0.1 0.2 0.2 -0.3 12/13/2005 02:00:00 0.9 0.7 2.3 0.4 0.8 0.7 2.3 0.4 0.8 0.6 2.3 0.4 47 86 156 165 -0.3 0 -0.1 -0.5 12/13/2005 02:10:00 0.7 0.6 2.3 0.4 0.6 0.5 2.3 0.4 0.7 0.6 2.3 0.4 151 0 151 165 -0.2 0 -0.1 -0.3 12/13/2005 02:20:00 0.6 0.4 1.5 0.4 0.5 0.3 1.5 0.4 0.5 0.3 1.5 0.4 148 8 151 165 -0.4 0 -0.3 -0.5 12/13/2005 02:30:00 0.6 0.4 1.5 0.4 0.6 0.3 1.5 0.4 0.5 0.3 1.1 0.4 123 14 123 165 -0.2 0 0.2 -0.3 12/13/2005 02:40:00 0.9 0.4 1.9 0.4 0.8 0.4 1.9 0.4 1.2 0.5 2.3 0.4 43 29 70 165 -0.1 0 0.2 -0.3 12/13/2005 02:50:00 1.5 0.5 2.3 0.7 1.7 0.4 2.6 0.7 1.7 0.4 2.6 1.1 71 10 80 165 0.1 0 0.2 -0.1 12/13/2005 03:00:00 1.9 0.4 2.6 1.1 2.1 0.4 2.6 1.5 2.1 0.3 3 1.5 85 3 84 165 0.1 0.1 0.4 -0.1 12/13/2005 03:10:00 2.7 0.2 3 2.3 2.8 0.2 3.4 2.3 2.8 0.3 3.4 2.3 66 11 82 165 0.2 0 0.4 0.2 12/13/2005 03:20:00 2.8 0.4 3.4 1.9 2.8 0.4 3.4 1.9 2.7 0.3 3 1.9 56 10 74 165 0.1 0 0.2 -0.1 12/13/2005 03:30:00 2.6 0.4 3.4 1.9 2.7 0.4 3.4 1.9 2.4 0.3 3.4 1.9 61 10 70 165 0.3 0 0.7 0.2 12/13/2005 03:40:00 3.9 0.3 4.2 3 4.1 0.3 4.6 3 3.8 0.3 4.2 3 83 3 84 165 0.4 0.1 0.7 0.2 12/13/2005 03:50:00 3.6 0.2 4.2 3 3.7 0.3 4.2 3.4 3.6 0.3 4.2 3 100 5 94 165 0.6 0.1 0.9 0.2 12/13/2005 04:00:00 3.5 0.3 4.2 3 3.6 0.3 4.2 3 3.4 0.3 4.2 2.6 102 3 105 165 0.8 0 0.9 0.7 12/13/2005 04:10:00 4.1 0.3 4.6 3.4 4.2 0.3 4.9 3.4 4 0.3 4.6 2.6 105 2 104 165 0.8 0 0.9 0.7 12/13/2005 04:20:00 4.7 0.3 5.3 4.2 4.8 0.3 5.3 4.2 4.5 0.3 5.3 3.8 113 3 113 165 0.8 0 0.9 0.9 12/13/2005 04:30:00 4.7 0.3 5.3 3.8 4.7 0.3 5.3 3.8 4.4 0.3 4.9 3.4 115 3 106 165 0.8 0 0.9 0.7 12/13/2005 04:40:00 4.6 0.3 5.3 3.8 4.6 0.3 5.3 4.2 4.4 0.3 4.9 3.4 112 3 110 165 0.8 0 0.9 0.9 12/13/2005 04:50:00 5.1 0.3 6.1 4.6 5.2 0.3 6.1 4.6 4.9 0.4 6.1 3.8 110 3 110 165 0.8 0 1.1 0.9 12/13/2005 05:00:00 5.3 0.4 6.5 3.8 5.5 0.4 6.5 4.2 5.2 0.4 6.1 3.8 111 4 113 165 0.9 0 0.9 0.9 12/13/2005 05:10:00 5.2 0.3 6.1 4.6 5.3 0.3 6.1 4.6 5 0.4 6.1 3.4 111 5 118 165 0.8 0 1.1 0.9 12/13/2005 05:20:00 5.4 0.5 6.5 4.2 5.6 0.5 6.5 4.2 5.1 0.5 6.1 3.8 103 7 112 165 0.8 0 0.9 0.9 12/13/2005 05:30:00 5.5 0.4 6.5 4.2 5.6 0.4 6.8 4.2 5.4 0.4 6.1 4.2 109 5 95 165 1 0 1.1 0.9 12/13/2005 05:40:00 5.7 0.3 6.8 4.9 5.8 0.3 6.8 5.3 5.5 0.4 6.8 4.6 113 3 116 165 1.1 0 1.4 0.9 12/13/2005 05:50:00 5.9 0.4 6.8 4.9 6.1 0.4 6.8 5.3 5.7 0.5 6.8 4.2 112 3 112 165 1.1 0 1.4 0.9 12/13/2005 06:00:00 6.1 0.6 7.6 4.6 6.3 0.6 7.6 4.6 5.9 0.6 7.2 4.2 116 5 117 165 1.1 0 1.4 0.9 12/13/2005 06:10:00 5.5 0.5 6.8 3.8 5.6 0.5 6.8 3.8 5.3 0.5 6.8 3.4 117 5 119 165 1 0 1.4 0.9 12/13/2005 06:20:00 6.7 0.8 8.4 4.6 6.9 0.8 8.8 4.9 6.3 0.8 8 4.2 109 7 107 165 1.2 0.1 1.4 0.9 12/13/2005 06:30:00 7.5 0.4 8.4 6.5 7.7 0.4 8.4 6.5 7.1 0.6 8.4 4.9 115 2 115 165 1.4 0 1.6 1.1 12/13/2005 06:40:00 7.5 0.5 8.8 6.5 7.6 0.5 8.8 6.5 7.2 0.6 8.8 5.3 114 3 111 165 1.4 0 1.6 1.4 12/13/2005 06:50:00 7.9 0.4 9.1 6.1 8 0.5 9.5 6.5 7.5 0.6 8.8 4.6 117 3 113 165 1.5 0 1.6 1.4 12/13/2005 07:00:00 8.1 0.4 9.5 6.5 8.3 0.4 9.9 6.5 7.9 0.5 9.1 6.5 119 3 117 165 1.6 0 1.6 1.4 12/13/2005 07:10:00 8.5 0.5 9.9 6.8 8.7 0.5 10.3 7.2 8.2 0.6 9.5 5.7 120 4 125 165 1.7 0 1.8 1.6 12/13/2005 07:20:00 8.6 0.6 9.9 6.8 8.7 0.6 9.9 6.8 8.4 0.6 10.3 6.5 123 5 122 165 1.8 0 1.8 1.6 12/13/2005 07:30:00 8.8 0.6 10.7 7.6 9 0.6 11.1 7.6 8.6 0.7 9.9 6.8 123 5 122 165 1.9 0 1.8 1.8 12/13/2005 07:40:00 8.9 0.8 11.1 6.5 9 0.8 11.1 6.5 8.6 0.8 11.1 6.1 121 5 114 165 2 0 2.1 1.8 12/13/2005 07:50:00 9.1 1 12.2 6.8 9.3 0.9 12.2 7.2 9 1 11.5 6.1 125 6 145 165 2.1 0 2.3 1.8 12/13/2005 08:00:00 9.5 1 12.6 7.2 9.6 1 13 6.5 9.2 1 12.6 6.5 131 9 135 165 2.1 0 2.3 1.8 12/13/2005 08:10:00 10.2 0.8 12.2 8 10.4 0.9 12.2 7.2 10 1 12.6 6.8 131 8 137 165 2.2 0 2.3 2.1 12/13/2005 08:20:00 10.3 1.3 14.1 7.2 10.5 1.3 14.5 7.2 10.1 1.5 13.7 5.7 130 7 126 165 2.3 0 2.3 2.3 12/13/2005 08:30:00 10.9 1 13.3 8 11 1 13.7 8 10.6 1 13 7.6 129 7 128 165 2.3 0 2.6 2.3 12/13/2005 08:40:00 10.2 1 13.3 7.6 10.4 1 13 8 10 1 12.2 7.2 126 6 121 165 2.3 0 2.3 2.3 12/13/2005 08:50:00 11 1 13.7 8 11.2 1 14.1 7.6 10.9 1.1 13.3 7.6 129 7 138 165 2.3 0 2.3 2.3 12/13/2005 09:00:00 11.1 1 15.3 8.4 11.3 1 15.3 8.8 10.9 1 14.9 8.4 130 6 130 165 2.3 0 2.3 2.3 12/13/2005 09:10:00 12.2 1 14.9 8 12.4 1 15.3 8 12.1 1 14.9 8.8 129 7 122 165 2.4 0 2.6 2.3 12/13/2005 09:20:00 11.3 1.1 14.1 7.6 11.4 1.1 14.5 8.4 11 1.3 14.1 7.2 126 8 115 165 2.4 0 2.6 2.3 12/13/2005 09:30:00 11 1 13.3 7.6 11.2 1 13.7 7.6 10.8 1.1 13.7 7.6 126 6 124 165 2.3 0 2.6 2.3 12/13/2005 09:40:00 10.6 1 13 8 10.8 1 13.3 8 10.3 1 13 6.8 121 7 121 165 2.3 0 2.6 2.1 12/13/2005 09:50:00 10.4 1.2 13.7 8 10.6 1.2 14.1 8 10.2 1.2 13.3 8 124 6 135 165 2.4 0 2.6 2.3 12/13/2005 10:00:00 11.8 1.5 15.3 8 12 1.5 15.3 8.4 11.6 1.4 15.3 8 124 5 128 165 2.4 0 2.6 2.3 12/13/2005 10:10:00 11.7 1 14.5 9.1 11.9 1.1 14.9 9.1 11.4 1.3 14.5 8 127 6 135 165 2.4 0 2.6 2.3 12/13/2005 10:20:00 12.6 1.2 15.3 8.4 12.8 1.2 15.6 9.1 12.5 1.2 15.6 9.1 124 6 120 165 2.5 0 2.8 2.3 12/13/2005 10:30:00 12.4 1 15.3 9.9 12.5 1 15.6 9.9 12.2 1.1 14.9 9.1 124 7 120 165 2.6 0 2.8 2.6 12/13/2005 10:40:00 11.6 1.3 15.3 8 11.8 1.3 15.3 8 11.3 1.4 14.5 8 126 7 124 165 2.7 0 2.8 2.6 12/13/2005 10:50:00 10.8 1.2 13.7 6.5 11 1.2 14.1 6.8 10.5 1.3 14.1 6.8 124 8 118 165 2.7 0 2.8 2.6 12/13/2005 11:00:00 12 1.3 15.3 8.8 12.2 1.4 16.1 9.1 11.7 1.4 15.3 8.4 123 6 117 165 2.8 0 3 2.8 12/13/2005 11:10:00 11.4 1.3 16.4 8 11.6 1.4 17.2 8 11.2 1.4 15.6 7.6 122 8 106 165 2.9 0 3 2.8 12/13/2005 11:20:00 11.6 1.2 15.3 8.4 11.9 1.2 14.9 8.8 11.3 1.4 16.1 7.2 122 5 116 165 2.9 0 3 2.8 12/13/2005 11:30:00 11.7 1.7 15.3 7.6 11.9 1.7 15.6 7.6 11.1 1.7 15.3 6.8 117 6 110 165 2.9 0 3 2.8 12/13/2005 11:40:00 11.2 1.8 16.1 6.5 11.4 1.9 16.1 6.8 10.6 1.8 14.9 6.5 116 8 112 165 3 0 3 2.8 12/13/2005 11:50:00 12.6 1.5 16.1 7.2 12.9 1.5 16.8 8 12 1.5 15.6 8 110 6 103 165 3 0 3 2.8 12/13/2005 12:00:00 11.5 1.3 14.9 7.2 11.7 1.3 14.9 7.6 10.8 1.4 13.7 6.8 113 6 111 165 3 0 3 2.8 12/13/2005 12:10:00 11.9 1.4 14.9 7.2 12.2 1.4 15.3 7.2 11.2 1.4 14.9 6.5 112 6 102 165 3 0 3 2.8 12/13/2005 12:20:00 12.4 1.5 16.1 6.1 12.7 1.5 16.4 6.1 11.8 1.6 14.9 5.7 111 6 106 165 2.9 0 3 2.8 12/13/2005 12:30:00 13.4 2.1 17.6 6.8 13.6 2.2 18.3 7.6 13 2 16.8 7.2 119 10 102 165 2.9 0 3 2.8 12/13/2005 12:40:00 16.4 1.5 19.9 11.8 16.5 1.5 20.2 11.5 15.8 1.7 19.1 10.3 119 6 119 165 2.4 0 2.8 2.3 12/13/2005 12:50:00 13 1.8 16.8 8.4 13.2 1.8 17.2 8.8 12.6 1.7 17.2 7.6 116 9 114 165 2.3 0 2.6 2.3 12/13/2005 13:00:00 14.1 1.3 16.8 10.3 14.3 1.3 17.2 10.7 13.4 1.5 17.2 9.5 111 5 114 165 2.3 0 2.6 2.3 12/13/2005 13:10:00 13.8 1.3 16.8 9.5 14 1.3 17.2 10.3 13.1 1.7 16.4 7.6 112 6 114 165 2.3 0 2.6 2.3 12/13/2005 13:20:00 14.1 1.1 17.6 10.7 14.4 1.1 17.6 11.1 13.6 1.4 16.8 8.8 109 5 106 165 2.3 0 2.6 2.1 12/13/2005 13:30:00 12.4 1.6 15.6 7.2 12.6 1.7 16.1 7.2 11.9 1.7 15.6 6.5 110 6 105 165 2.2 0 2.3 2.1 12/13/2005 13:40:00 13.2 1.7 17.6 9.5 13.4 1.7 17.9 9.9 12.5 1.8 17.2 8.4 107 6 102 165 2.3 0 2.3 2.1 12/13/2005 13:50:00 13.8 1.7 19.1 8.4 14.1 1.8 19.1 8.8 13.1 1.9 17.6 7.6 115 8 110 165 2.3 0 2.3 2.3 12/13/2005 14:00:00 12.6 1.3 15.3 8.8 12.8 1.3 15.3 9.1 11.9 1.3 14.9 8.4 111 8 122 165 2.2 0 2.3 2.3 12/13/2005 14:10:00 13.6 1.5 16.8 9.9 13.8 1.5 17.2 9.9 12.7 1.5 16.1 7.6 107 5 107 165 2.1 0 2.3 2.1 12/13/2005 14:20:00 13.5 1.7 17.6 8.8 13.7 1.8 17.6 9.1 12.8 1.8 16.8 8.4 107 5 107 165 2.3 0 2.3 2.1 12/13/2005 14:30:00 13.3 1.7 17.2 8.8 13.4 1.7 17.6 8 12.5 1.9 16.4 7.6 111 7 110 165 2.4 0 2.6 2.3 12/13/2005 14:40:00 12.6 1.8 17.6 7.2 12.8 1.9 18.3 7.2 11.9 2 17.6 6.5 110 8 105 165 2.7 0 2.8 2.6 12/13/2005 14:50:00 12.6 1.7 16.8 7.2 12.8 1.7 17.2 8.4 11.9 1.7 16.1 8 113 9 115 165 2.7 0 2.8 2.6 12/13/2005 15:00:00 14.1 1.6 17.6 9.5 14.4 1.6 17.9 9.1 13.4 1.6 17.2 9.1 109 6 107 165 2.6 0.1 2.8 2.6 12/13/2005 15:10:00 13.9 1.9 18.7 8 14.1 2 18.3 8.4 13.1 2 18.3 8.4 109 6 107 165 2.4 0 2.6 2.3 12/13/2005 15:20:00 15 1.8 18.3 9.1 15.2 1.9 18.7 8.4 14.3 1.8 17.9 8.4 107 5 108 165 2.4 0 2.6 2.3 12/13/2005 15:30:00 13.6 1.8 17.2 6.8 13.8 1.8 17.9 6.5 12.9 1.9 16.8 6.5 107 6 108 165 2.4 0 2.8 2.6 12/13/2005 15:40:00 15 1.7 19.5 9.9 15.2 1.8 19.9 9.9 14 2 18.7 9.1 106 7 99 165 2.7 0 2.8 2.6 12/13/2005 15:50:00 14.5 1.3 17.9 11.1 14.8 1.3 18.3 11.5 13.7 1.5 19.1 8.4 106 6 102 165 3 0 3.3 2.8 12/13/2005 16:00:00 14.7 1.9 19.9 9.1 15 1.9 20.2 9.5 13.7 2.1 20.2 8 111 7 116 165 3 0 3.3 3 12/13/2005 16:10:00 14.8 2.1 19.9 9.5 15 2.1 20.2 9.5 14 2.1 19.5 9.1 113 9 116 165 3 0 3.3 3 12/13/2005 16:20:00 16 1.8 20.6 10.3 16.3 1.8 21 11.1 15.3 1.9 19.1 9.1 111 7 109 165 3.1 0 3.3 3 12/13/2005 16:30:00 15.5 3.1 22.1 8.4 15.7 3.1 22.6 8.4 14.6 3.2 21.8 7.6 111 9 107 165 3.2 0 3.3 3 12/13/2005 16:40:00 16 1.8 19.5 10.3 16.2 1.9 19.9 9.5 15.2 2 19.9 9.5 112 7 112 165 3.2 0 3.3 3 12/13/2005 16:50:00 15.8 1.9 20.2 11.1 16.1 2 20.6 10.3 14.6 2.4 19.5 8.8 110 6 111 165 3.2 0 3.3 3.3 12/13/2005 17:00:00 16.5 2.2 21 8.8 16.7 2.3 21.4 9.1 15.4 2.4 20.6 9.9 109 8 103 165 3.2 0 3.3 3.3 12/13/2005 17:10:00 16.6 1.9 21 12.2 16.9 1.9 22.1 12.6 15.4 2.1 20.2 10.3 107 7 102 165 3.2 0 3.3 3 12/13/2005 17:20:00 17.6 2.3 23.3 10.3 17.9 2.4 23.3 10.3 16.9 2.4 22.6 10.3 111 6 112 165 3.2 0 3.3 3 12/13/2005 17:30:00 17.4 2.5 22.1 10.3 17.7 2.4 22.6 10.7 16.3 2.5 22.9 9.1 108 7 102 165 3.2 0 3.3 3 12/13/2005 17:40:00 17 2.2 22.9 10.7 17.3 2.2 23.7 10.7 15.7 2.5 22.9 10.7 106 6 101 165 3.2 0 3.3 3 12/13/2005 17:50:00 16.1 2 21 10.7 16.4 2.1 21.8 11.1 15.2 2.2 21.8 10.3 107 7 106 165 3.2 0 3.3 3 12/13/2005 18:00:00 16.1 2.4 21 9.5 16.4 2.5 21.4 10.3 15 2.5 21.8 8.8 105 6 112 165 3.2 0 3.3 3 12/13/2005 18:10:00 15.8 2.2 21 10.7 16.1 2.2 21.8 10.3 14.7 2.1 19.9 8.4 102 7 99 165 3.2 0 3.3 3 12/13/2005 18:20:00 16.8 2.6 22.1 10.3 17.1 2.6 22.6 9.9 15.9 2.6 21.4 9.1 106 7 104 165 3.2 0 3.3 3 12/13/2005 18:30:00 16.9 2.3 22.9 10.3 17.2 2.3 22.9 11.1 16 2.4 21.8 11.1 107 7 113 165 3.2 0 3.3 3.3 12/13/2005 18:40:00 17 2.1 23.3 11.8 17.2 2.1 23.3 12.2 15.8 2.3 22.6 9.5 106 7 105 165 3.2 0 3.3 3.3 12/13/2005 18:50:00 17.9 2.1 22.6 11.5 18.3 2.1 22.9 11.8 16.6 2.3 22.1 10.3 105 6 105 165 3.2 0 3.3 3.3 12/13/2005 19:00:00 18.2 2.1 22.9 12.2 18.5 2.1 23.7 11.8 16.9 2.2 22.6 10.7 108 8 108 165 3.2 0 3.5 3 12/13/2005 19:10:00 18.2 1.9 22.6 13 18.5 1.9 22.9 13.3 17.2 2 21.8 12.2 106 7 102 165 3.3 0 3.5 3.3 12/13/2005 19:20:00 19.2 2.3 23.7 13 19.5 2.3 24 13 17.9 2.4 22.9 11.8 106 6 99 165 3.3 0 3.5 3.3 12/13/2005 19:30:00 18.5 2.7 24 11.5 18.8 2.7 24.4 9.9 17.5 2.7 23.7 11.1 107 6 99 165 3.3 0 3.5 3.3 12/13/2005 19:40:00 18.3 2.2 24.8 11.5 18.6 2.2 25.2 11.8 17.3 2.5 25.6 10.7 108 7 106 165 3.3 0 3.5 3.3 12/13/2005 19:50:00 18.1 2.5 23.3 12.2 18.4 2.5 23.7 11.8 16.9 2.6 23.3 10.3 108 7 102 165 3.3 0 3.5 3.3 12/13/2005 20:00:00 18.9 2.5 23.7 9.9 19.2 2.5 23.7 10.7 17.9 2.5 24 11.5 107 7 98 165 3.3 0 3.5 3.3 12/13/2005 20:10:00 17.1 2.2 21.8 9.9 17.3 2.3 22.6 9.5 16.1 2.1 21.4 10.3 105 8 112 165 3.3 0 3.5 3.3 12/13/2005 20:20:00 17.9 2 23.7 12.6 18.2 2.1 23.7 12.2 16.7 2.1 22.9 10.7 108 7 116 165 3.3 0 3.5 3.3 12/13/2005 20:30:00 17.6 2.4 23.7 12.2 17.9 2.5 24 11.1 16.3 2.5 22.1 10.7 109 7 110 165 3.4 0 3.5 3.3 12/13/2005 20:40:00 18.2 2.4 24.4 13 18.5 2.5 25.2 13.3 16.9 2.6 23.7 11.1 108 7 110 165 3.3 0 3.5 3.3 12/13/2005 20:50:00 17.6 2.2 22.6 10.7 17.8 2.2 23.3 11.1 16.3 2.1 20.6 10.3 105 7 97 165 3.4 0 3.5 3.3 12/13/2005 21:00:00 18.8 2.5 24.8 11.5 19.1 2.5 24.8 10.7 17.2 2.7 24 9.5 108 8 104 165 3.4 0 3.5 3.3 12/13/2005 21:10:00 17.4 2.4 22.9 11.8 17.6 2.4 23.3 11.5 16.5 2.6 22.6 10.7 110 7 109 165 3.5 0 3.5 3.3 12/13/2005 21:20:00 17.1 2.4 23.3 11.8 17.3 2.4 23.7 12.2 15.9 2.7 22.6 9.9 111 8 110 165 3.5 0 3.5 3.5 12/13/2005 21:30:00 19.1 2.9 26.8 11.5 19.3 2.9 27.5 11.1 18 3.1 26 10.7 107 6 107 165 3.5 0 3.5 3.5 12/13/2005 21:40:00 19.3 2.1 24.8 13.7 19.6 2 24.8 13 18.4 2.1 22.6 11.8 107 6 105 165 3.4 0 3.5 3.3 12/13/2005 21:50:00 19 2.7 27.1 12.2 19.3 2.8 27.5 12.6 18.1 3.1 26.3 11.5 109 6 114 165 3.5 0 3.5 3.3 12/13/2005 22:00:00 18 3.1 24.8 9.9 18.3 3.1 25.2 9.9 16.9 3.1 24 10.7 109 6 106 165 3.3 0 3.5 3.3 12/13/2005 22:10:00 16.7 2.3 22.9 10.7 17.1 2.3 23.7 11.1 15.6 2.4 21.8 9.5 102 7 104 165 3.4 0 3.5 3.3 12/13/2005 22:20:00 19.1 2.8 25.6 10.7 19.3 2.8 26 11.5 17.7 3.1 24.8 10.3 107 6 106 165 3.4 0 3.5 3.3 12/13/2005 22:30:00 17.7 2 22.9 11.1 18 2.1 23.3 11.5 16.6 2.1 22.6 10.3 103 7 100 165 3.5 0 3.5 3.5 12/13/2005 22:40:00 18.9 2.5 25.2 12.2 19.2 2.6 25.6 13.3 17.7 2.6 25.6 11.5 107 7 115 165 3.6 0 3.8 3.5 12/13/2005 22:50:00 18.2 2.6 23.3 10.7 18.5 2.6 24 11.1 17 2.7 23.3 9.9 109 7 102 165 3.6 0 3.8 3.5 12/13/2005 23:00:00 16.4 2.4 21.8 9.9 16.7 2.4 21.8 9.9 15.7 2.4 21.8 10.3 106 8 107 165 3.6 0 3.8 3.5 12/13/2005 23:10:00 17.5 2.2 24 12.2 17.8 2.3 24.4 12.2 16.3 2.5 22.6 10.7 103 7 105 165 3.6 0 3.8 3.5 12/13/2005 23:20:00 17.4 2.1 21.8 9.9 17.8 2.1 22.1 9.9 16.3 2.1 21.4 9.1 100 7 94 165 3.7 0 3.8 3.5 12/13/2005 23:30:00 17.2 1.9 22.6 11.5 17.4 1.9 22.1 11.5 15.8 2.1 21.8 10.3 99 7 98 165 3.7 0 3.8 3.5 12/13/2005 23:40:00 17.9 2.2 22.6 11.5 18.2 2.2 22.9 11.8 16.7 2.2 21.8 10.3 100 7 107 165 3.8 0 3.8 3.5 12/13/2005 23:50:00 18.4 2 22.6 11.8 18.7 2.1 22.9 12.2 17 2.1 21.4 10.7 101 6 109 165 3.8 0 3.8 3.5 12/14/2005 00:00:00 17.4 1.8 22.6 10.3 17.7 1.8 22.6 11.1 16.1 2 20.2 10.3 103 7 88 165 3.8 0 4 3.8 12/14/2005 00:10:00 17.8 2 21.8 10.3 18.2 2 22.6 11.1 16.6 2.1 21 10.3 96 7 101 165 3.8 0 4 3.8 12/14/2005 00:20:00 18.5 2.5 22.9 12.2 18.8 2.6 23.3 11.8 17.3 2.6 22.6 9.9 97 7 106 165 3.8 0 4 3.8 12/14/2005 00:30:00 17.9 2 22.6 11.5 18.2 2.1 23.3 11.5 16.6 2 21.4 11.5 95 9 84 165 3.8 0 4 3.8 12/14/2005 00:40:00 16.9 2.3 21.8 11.5 17.2 2.3 21.8 11.5 15.8 2.2 21 9.5 94 8 102 165 3.8 0 4 3.8 12/14/2005 00:50:00 16.8 2.3 22.9 10.3 17.1 2.3 23.7 10.3 15.5 2.2 21 10.7 95 8 94 165 3.8 0 4 3.8 12/14/2005 01:00:00 17.7 1.9 22.1 11.5 18 2 22.9 11.8 16.7 2.1 22.1 11.1 94 8 91 165 3.9 0 4 3.8 12/14/2005 01:10:00 17.7 1.9 22.9 12.6 18 1.9 23.3 13 16.4 2 21 11.1 97 7 95 165 4 0 4 3.8 12/14/2005 01:20:00 17.8 2.5 23.7 11.8 18.1 2.5 24 12.2 16.8 2.4 23.3 11.5 93 8 95 165 4 0 4.3 3.8 12/14/2005 01:30:00 19 2.4 24.8 13.3 19.3 2.4 25.2 13.3 17.6 2.6 24.8 11.1 96 8 108 165 4 0 4.3 3.8 12/14/2005 01:40:00 18.7 2.5 26 10.3 19.1 2.5 26.8 10.7 17.5 2.4 24.8 11.5 92 8 92 165 4 0 4.3 3.8 12/14/2005 01:50:00 18.1 2.7 24.8 11.5 18.5 2.8 24.8 11.5 17.3 2.7 25.2 11.1 93 8 101 165 4 0 4.3 3.8 12/14/2005 02:00:00 17.7 2.4 24.4 11.5 18.1 2.4 24.8 11.1 16.8 2.3 23.3 11.5 93 8 92 165 4 0 4.3 3.8 12/14/2005 02:10:00 18.6 2.6 24.8 10.7 18.9 2.6 25.2 11.1 17.5 2.7 24 10.3 95 9 101 165 4 0 4.3 4 12/14/2005 02:20:00 18.5 2.2 23.7 11.8 18.8 2.2 24 12.6 17.5 2.1 22.9 11.1 94 7 90 165 4.1 0 4.3 4 12/14/2005 02:30:00 18.6 2.2 24.4 13.3 19 2.3 24.4 13.7 17.5 2.3 22.9 11.5 93 8 91 165 4.1 0 4.3 4 12/14/2005 02:40:00 18.9 2.2 24.8 12.6 19.2 2.3 24.8 11.8 17.7 2.2 23.7 10.7 94 8 94 165 4.1 0 4.3 4 12/14/2005 02:50:00 18.4 2.2 23.3 12.2 18.7 2.4 24 11.5 17.3 2.3 22.6 11.1 93 7 92 165 4.1 0 4.3 4.3 12/14/2005 03:00:00 18.1 2.4 23.3 12.2 18.5 2.4 23.7 11.8 17 2.3 22.1 11.1 92 8 100 165 4.2 0 4.3 4.3 12/14/2005 03:10:00 18 2.4 25.2 12.6 18.3 2.5 25.6 12.6 16.9 2.4 23.3 11.5 92 9 87 165 4.2 0 4.5 4.3 12/14/2005 03:20:00 18.5 2.2 24 11.8 18.9 2.2 24.4 12.2 17.3 2.2 22.9 11.1 94 9 102 165 4.3 0 4.5 4.3 12/14/2005 03:30:00 20.6 2.5 26 11.5 20.9 2.6 26.3 11.5 19.4 2.5 24.4 13 96 7 102 165 4.3 0 4.5 4.3 12/14/2005 03:40:00 20.8 2.3 26 14.5 21.2 2.3 26.3 14.9 19.6 2.6 26 11.8 97 7 100 165 4.3 0 4.5 4.3 12/14/2005 03:50:00 19.8 2.3 25.6 13 20.2 2.4 26 13.7 18.6 2.1 24 13.3 95 7 86 165 4.4 0 4.5 4.3 12/14/2005 04:00:00 20 2.3 25.6 14.5 20.3 2.3 25.2 14.9 18.7 2.6 25.2 12.2 96 7 98 165 4.4 0 4.5 4.3 12/14/2005 04:10:00 20.6 2.7 26 13.3 21 2.7 26.8 14.1 19.3 2.6 25.2 13 97 7 99 165 4.4 0 4.5 4.5 12/14/2005 04:20:00 20.5 2.4 27.1 14.5 20.9 2.5 27.5 14.1 19 2.5 26 13.3 96 8 103 165 4.5 0 4.5 4.5 12/14/2005 04:30:00 19.9 2.5 25.2 13.7 20.3 2.5 26 13.7 18.8 2.5 25.2 13.7 95 8 98 165 4.5 0 4.5 4.3 12/14/2005 04:40:00 20.5 2.3 26.3 14.5 20.9 2.4 26.8 14.9 19.4 2.4 26 11.8 96 8 97 165 4.5 0 4.8 4.5 12/14/2005 04:50:00 20.6 2.6 26.8 13 21 2.6 27.1 13.3 19.3 2.5 25.6 13 96 7 98 165 4.5 0 4.8 4.5 12/14/2005 05:00:00 20.9 2.3 27.9 13.7 21.4 2.3 28.3 14.5 19.4 2.6 27.1 13.7 98 8 105 165 4.5 0 4.5 4.5 12/14/2005 05:10:00 20.3 2.5 26 12.2 20.6 2.6 26.3 12.6 18.8 2.6 26 12.2 96 7 102 165 4.5 0 4.8 4.3 12/14/2005 05:20:00 20.5 2.5 26 14.1 20.9 2.6 27.1 14.1 19.2 2.5 27.5 13.3 94 8 99 165 4.5 0 4.8 4.5 12/14/2005 05:30:00 20.3 2.5 26 13 20.7 2.6 26.8 13 19 2.5 24 11.8 95 9 91 165 4.5 0 4.8 4.5 12/14/2005 05:40:00 20.2 2.4 25.6 14.1 20.6 2.4 26 14.5 19 2.4 25.2 12.6 94 7 106 165 4.5 0 4.8 4.5 12/14/2005 05:50:00 18.7 2.3 24 12.2 19 2.4 24 11.8 17.7 2.4 24.8 12.6 91 8 92 165 4.5 0 4.8 4.5 12/14/2005 06:00:00 18.6 2.6 25.2 13 19 2.6 26 13 17.7 2.6 24.4 11.8 91 8 91 165 4.5 0 4.5 4.5 12/14/2005 06:10:00 19.4 2.8 26.8 11.5 19.7 2.8 27.5 12.2 18.3 2.7 26.8 12.6 91 8 89 165 4.5 0 4.5 4.5 12/14/2005 06:20:00 19.3 2.4 24 12.2 19.6 2.4 24.8 13 18.2 2.4 23.3 11.5 90 9 85 165 4.5 0 4.8 4.5 12/14/2005 06:30:00 19.5 2.5 26 13.7 19.9 2.6 26 14.1 18.3 2.5 23.7 12.6 90 8 94 165 4.6 0 4.8 4.5 12/14/2005 06:40:00 19.2 2.3 25.6 13.7 19.5 2.3 26 13.7 18 2.3 24.8 13 92 8 92 165 4.6 0 4.8 4.5 12/14/2005 06:50:00 19.9 2.9 27.5 12.2 20.2 3.1 27.9 11.8 18.6 2.8 25.2 11.5 91 8 87 165 4.5 0 4.8 4.5 12/14/2005 07:00:00 20 2.6 24.8 12.2 20.4 2.6 25.2 13.3 18.9 2.6 24.8 10.7 90 8 95 165 4.6 0 4.8 4.5 12/14/2005 07:10:00 20.1 2.7 26.3 12.2 20.5 2.8 27.1 13 19.1 2.6 26 12.6 91 8 91 165 4.6 0 4.8 4.5 12/14/2005 07:20:00 21 2.8 29.1 14.9 21.4 2.8 28.3 15.3 19.8 2.7 26.3 12.6 94 8 84 165 4.6 0 4.8 4.5 12/14/2005 07:30:00 20 2.6 26 13.7 20.4 2.6 26.3 14.1 18.7 2.4 25.6 13.7 90 8 92 165 4.6 0 4.8 4.5 12/14/2005 07:40:00 19.8 2.7 26 13.7 20.2 2.7 26.3 13.7 18.5 2.5 25.2 11.1 94 8 108 165 4.6 0 4.8 4.5 12/14/2005 07:50:00 19.3 2.5 26.3 13 19.7 2.5 26.8 13 18 2.7 25.6 11.8 91 8 82 165 4.6 0 4.8 4.5 12/14/2005 08:00:00 20.4 2.8 27.1 11.8 20.7 2.9 27.5 12.2 19 2.8 26 11.1 94 8 91 165 4.7 0 4.8 4.5 12/14/2005 08:10:00 20 2.5 26 13 20.4 2.5 26.3 13.7 18.8 2.5 26 10.7 92 8 91 165 4.7 0 4.8 4.5 12/14/2005 08:20:00 19.7 2.5 26 13.7 20 2.5 26.8 14.1 18.2 2.3 24.4 12.6 93 8 85 165 4.7 0 5 4.8 12/14/2005 08:30:00 19.9 2.3 24.8 12.6 20.2 2.4 25.2 12.6 18.8 2.5 25.6 11.5 93 8 98 165 4.9 0 5 4.8 12/14/2005 08:40:00 19.3 2.2 24 13.3 19.6 2.2 24.4 13.7 18 2.2 22.9 12.6 94 7 106 165 4.9 0 5 4.8 12/14/2005 08:50:00 19.9 2.1 24.4 14.1 20.3 2.1 25.2 14.5 18.6 2.2 23.3 12.6 93 8 84 165 5 0 5 5 12/14/2005 09:00:00 19.4 2.6 24.4 13.7 19.8 2.6 24.8 14.1 18 2.6 24.4 12.6 92 7 106 165 5.1 0 5.2 5 12/14/2005 09:10:00 20 2.4 26.3 13.7 20.4 2.4 26.3 14.1 18.7 2.3 24.8 12.2 96 8 103 165 5.1 0 5.2 5 12/14/2005 09:20:00 20.7 2.3 26 14.1 21 2.3 26.3 14.1 19.3 2.4 26 13.3 99 7 102 165 5.2 0 5.2 5 12/14/2005 09:30:00 20.3 2.1 25.6 14.9 20.7 2.2 26 14.5 19 2.4 24.8 13.3 97 7 89 165 5.2 0 5.5 5.2 12/14/2005 09:40:00 20.5 2.4 25.6 14.1 20.9 2.4 25.2 14.5 19.1 2.4 24.4 13 95 8 94 165 5.2 0 5.5 5.2 12/14/2005 09:50:00 19.9 2.5 26.3 13 20.3 2.5 26.8 13.3 18.6 2.5 24.4 12.6 96 7 102 165 5.3 0 5.5 5.2 12/14/2005 10:00:00 20.3 2.1 25.6 13.7 20.7 2.2 26 14.5 18.8 2.2 24 13.7 100 6 104 165 5.4 0 5.5 5.2 12/14/2005 10:10:00 21.3 2.1 26.3 15.3 21.7 2.1 26.8 16.1 19.9 2.5 27.1 14.1 97 7 99 165 5.5 0 5.7 5.5 12/14/2005 10:20:00 20.8 2.3 26.3 13.3 21.1 2.4 26.8 13.7 19.4 2.6 26.8 11.8 105 6 107 165 5.4 0 5.5 5.5 12/14/2005 10:30:00 20.7 2.3 25.6 13.7 21.1 2.3 25.6 14.1 19.2 2.4 25.2 14.1 101 6 103 165 5.4 0 5.5 5.5 12/14/2005 10:40:00 20.8 2.2 24.8 13.3 21.1 2.3 25.2 14.1 19.4 2.3 24.8 13 97 6 102 165 5.5 0 5.7 5.5 12/14/2005 10:50:00 20.7 1.9 25.2 14.1 21 2 25.6 14.1 19.2 2.2 24.4 12.2 97 7 104 165 5.5 0 5.7 5.5 12/14/2005 11:00:00 20.7 2.1 25.2 14.5 21 2.1 26 15.3 19.1 2.2 23.7 13 98 7 91 165 5.6 0 5.7 5.5 12/14/2005 11:10:00 20.9 2 25.6 15.6 21.2 2.1 26 15.6 19.3 2.2 25.6 14.1 101 7 100 165 5.6 0 5.7 5.5 12/14/2005 11:20:00 22.5 2.4 27.9 16.1 22.8 2.5 27.9 16.8 20.9 2.7 28.3 15.3 104 6 111 165 5.6 0 5.7 5.5 12/14/2005 11:30:00 20.9 2.5 27.1 14.1 21.2 2.5 27.1 14.1 19.7 2.7 25.2 13.3 108 7 108 165 5.6 0 5.7 5.5 12/14/2005 11:40:00 20.3 2.5 26.3 13.3 20.6 2.6 26.8 13.3 19 2.7 25.2 12.2 108 6 107 165 5.6 0 5.7 5.5 12/14/2005 11:50:00 20.4 2.3 26.3 14.1 20.7 2.3 26 14.1 19.3 2.3 24.8 12.2 110 6 122 165 5.7 0 5.7 5.7 12/14/2005 12:00:00 18.1 1.9 23.7 13.3 18.4 2 23.7 12.6 17.1 2.3 22.6 11.1 111 6 107 165 5.7 0 5.7 5.7 12/14/2005 12:10:00 18.1 1.7 22.1 13 18.3 1.8 22.9 12.6 17.1 2 22.1 11.1 111 6 106 165 5.7 0 5.7 5.5 12/14/2005 12:20:00 16.8 1.7 21 11.5 17.1 1.6 21.8 11.8 15.8 1.8 20.2 11.1 114 7 110 165 5.7 0 5.7 5.7 12/14/2005 12:30:00 16.2 1.8 21 9.9 16.5 1.8 21 10.3 15.3 1.9 20.6 9.5 115 7 111 165 5.7 0 5.7 5.7 12/14/2005 12:40:00 16 1.5 21 11.8 16.2 1.5 21.4 11.8 15.2 1.6 21 11.5 122 9 118 165 5.7 0 5.7 5.7 12/14/2005 12:50:00 15.9 1.2 19.1 11.8 16.1 1.2 19.5 12.2 15.6 1.3 18.7 12.6 130 6 136 165 5.7 0 5.7 5.7 12/14/2005 13:00:00 14.5 1.5 17.9 9.9 14.8 1.5 18.3 10.3 14.4 1.6 17.9 10.3 130 7 128 165 5.7 0 5.7 5.7 12/14/2005 13:10:00 15.7 1.5 19.5 11.5 15.9 1.5 19.9 11.5 15.4 1.5 19.9 11.1 131 8 139 165 5.7 0 5.7 5.7 12/14/2005 13:20:00 16.5 1.7 21.8 11.5 16.7 1.8 22.1 11.8 16.2 1.7 20.2 11.5 132 7 122 165 5.7 0 5.7 5.7 12/14/2005 13:30:00 17.6 1.5 21.8 14.1 17.8 1.6 22.1 13 17.3 1.6 21.4 13 133 7 123 165 5.7 0 5.7 5.7 12/14/2005 13:40:00 16.3 1.5 20.2 12.6 16.5 1.5 20.6 12.2 15.9 1.5 20.6 12.2 136 8 135 165 5.6 0 5.7 5.5 12/14/2005 13:50:00 16.8 1.7 20.2 11.8 17 1.7 20.2 11.8 16.3 1.8 20.6 11.1 136 7 134 165 5.6 0 5.7 5.5 12/14/2005 14:00:00 16.2 1.6 19.9 12.2 16.4 1.6 20.6 12.6 15.9 1.6 19.9 11.1 138 6 128 165 5.5 0 5.7 5.5 12/14/2005 14:10:00 16.4 1.4 20.2 12.2 16.5 1.4 20.2 11.8 16.1 1.5 19.9 11.8 139 7 139 165 5.5 0 5.5 5.5 12/14/2005 14:20:00 17.2 1.7 21.4 11.8 17.4 1.7 21.4 11.8 16.7 1.8 21.8 10.3 137 7 131 165 5.4 0 5.5 5.2 12/14/2005 14:30:00 18.2 1.4 22.6 13 18.4 1.4 22.6 12.6 17.9 1.6 22.1 12.2 138 6 130 165 5.4 0 5.5 5.2 12/14/2005 14:40:00 18.8 1.5 22.6 15.3 19 1.5 22.6 15.6 18.5 1.7 22.9 14.5 137 6 134 165 5.3 0 5.5 5.2 12/14/2005 14:50:00 17.8 1.3 21 13.7 18 1.4 21 13.7 17.4 1.5 21 12.6 140 7 132 165 5.2 0 5.5 5 12/14/2005 15:00:00 18.1 1.3 22.1 14.5 18.3 1.3 21.8 14.9 17.7 1.5 21.8 13 140 6 143 165 5.2 0 5.5 5.2 12/14/2005 15:10:00 18.6 1.8 22.9 13.7 18.8 1.8 23.7 14.1 18.2 2.1 22.6 13 138 7 122 165 5.2 0 5.5 5.2 12/14/2005 15:20:00 19.4 1.8 23.7 14.5 19.6 1.7 24.4 14.5 19 1.8 24 13.7 140 7 134 165 5.2 0 5.5 5.2 12/14/2005 15:30:00 18.9 1.7 22.9 13 19.1 1.7 23.3 13.7 18.6 1.7 24 14.5 140 7 139 165 5.2 0 5.5 5.2 12/14/2005 15:40:00 19.6 1.5 22.6 14.9 19.8 1.5 22.9 14.9 19.3 1.7 23.3 13 141 7 142 165 5.2 0 5.5 5.2 12/14/2005 15:50:00 20.1 1.7 24 16.4 20.2 1.7 24.4 16.1 19.8 2 24.4 14.1 141 6 138 165 5.2 0 5.2 5.2 12/14/2005 16:00:00 19.4 1.6 22.9 14.5 19.5 1.7 23.3 14.1 19 1.9 23.3 13.3 143 6 145 165 5.2 0 5.2 5.2 12/14/2005 16:10:00 19 1.5 23.3 15.6 19.1 1.5 23.3 15.3 18.7 1.7 22.6 13 142 6 138 165 5.2 0 5.2 5 12/14/2005 16:20:00 18.2 1.2 21 15.3 18.3 1.2 21.4 15.3 18.1 1.3 21 14.5 143 5 145 165 5.2 0 5.2 5 12/14/2005 16:30:00 17.9 1.2 20.6 14.9 18 1.2 20.6 14.5 17.8 1.3 20.6 14.5 143 6 145 165 5.2 0 5.2 5 12/14/2005 16:40:00 17.2 1 20.2 14.5 17.3 1 19.5 13.7 17 1.1 19.9 13.3 145 5 145 165 5.1 0 5.2 5 12/14/2005 16:50:00 17.6 1.1 19.9 14.5 17.7 1.1 20.2 14.5 17.3 1.5 20.2 12.6 147 4 145 165 5.1 0 5.2 5 12/14/2005 17:00:00 18 1.1 21 15.3 18.1 1.1 20.6 14.9 18 1.3 20.6 14.1 148 4 145 165 5.1 0 5.2 5 12/14/2005 17:10:00 17.4 1.3 21.4 13 17.4 1.2 21 13.7 16.9 1.3 20.6 13 146 4 151 165 5.1 0 5.2 5 12/14/2005 17:20:00 17.6 1.3 20.6 13.3 17.7 1.3 20.6 13.3 17.1 1.5 20.2 12.6 147 5 150 165 5.1 0 5.2 5 12/14/2005 17:30:00 17 1.5 20.6 14.1 17.1 1.5 20.6 13.7 16.4 1.7 20.2 11.8 149 4 151 165 5.1 0 5.2 5 12/14/2005 17:40:00 17.2 1.1 19.5 14.1 17.2 1.1 19.5 13.7 16.6 1.5 19.9 12.2 148 5 151 165 5.1 0 5.2 5 12/14/2005 17:50:00 17.1 1.1 19.9 13.7 17.1 1.1 19.9 13.7 16.7 1.3 19.1 12.6 150 3 148 165 5 0 5.2 5 12/14/2005 18:00:00 16.5 1.1 19.5 12.2 16.5 1.1 19.1 13 16.1 1.3 19.5 11.5 151 4 148 165 5 0 5 5 12/14/2005 18:10:00 16.9 1.3 20.2 13 16.9 1.3 20.2 12.6 16.6 1.5 20.2 12.2 150 7 159 165 5 0 5 5 12/14/2005 18:20:00 15.7 1.2 18.7 12.6 15.7 1.1 18.7 12.6 15.4 1.4 19.1 12.2 153 5 162 165 4.9 0 5 5 12/14/2005 18:30:00 15.6 1.1 17.9 11.8 15.6 1 17.9 12.2 15.4 1.1 17.9 11.5 151 5 153 165 4.9 0 5 5 12/14/2005 18:40:00 15.9 1.1 18.7 13 15.8 1 18.7 13 15.6 1.2 18.3 13 152 4 159 165 4.9 0 5 4.8 12/14/2005 18:50:00 16.6 1.1 19.1 13.7 16.5 1 19.1 12.6 16.4 1.2 19.5 11.8 152 5 140 165 4.9 0 5 4.8 12/14/2005 19:00:00 15.2 1 17.6 13 15.2 1 17.9 13 15 1.2 17.9 11.1 152 4 160 165 4.8 0 5 4.8 12/14/2005 19:10:00 15.9 1 18.3 13 15.8 0.9 17.9 13 15.9 1 19.1 13.3 154 4 151 165 4.8 0 5 4.8 12/14/2005 19:20:00 15.5 1 18.3 12.2 15.4 1 17.9 12.2 15.7 1 17.9 13 155 5 164 165 4.7 0 4.8 4.8 12/14/2005 19:30:00 15.2 0.8 17.6 13 15.2 0.8 16.8 13 15.3 1 17.6 11.8 153 3 150 165 4.7 0 4.8 4.5 12/14/2005 19:40:00 14.5 0.8 16.8 11.8 14.6 0.8 17.2 11.8 14.5 1 17.6 11.1 153 4 157 165 4.6 0 4.8 4.5 12/14/2005 19:50:00 14.9 0.9 16.8 11.8 14.8 0.8 16.8 11.5 15.3 0.9 17.6 12.2 156 4 162 165 4.6 0 4.8 4.5 12/14/2005 20:00:00 13.5 0.9 15.6 11.1 13.4 0.8 15.3 11.1 13.8 0.9 16.4 11.8 157 6 159 165 4.6 0 4.8 4.5 12/14/2005 20:10:00 13.9 0.8 16.1 11.8 13.9 0.7 15.6 12.2 14.2 0.9 16.1 11.8 155 3 159 165 4.6 0 4.8 4.5 12/14/2005 20:20:00 13.8 0.8 16.1 12.2 13.8 0.8 16.1 12.2 14 1 16.8 11.5 152 4 157 165 4.6 0 4.8 4.5 12/14/2005 20:30:00 14.4 0.7 16.1 12.6 14.4 0.6 16.1 12.6 14.3 0.8 16.1 11.8 149 3 152 165 4.6 0 4.8 4.5 12/14/2005 20:40:00 14.1 0.9 16.1 11.8 14.1 0.9 16.1 11.8 14 1 16.8 11.5 150 3 153 165 4.6 0 4.8 4.5 12/14/2005 20:50:00 14.2 1 16.8 11.5 14.3 1 17.2 11.5 13.9 1.2 17.2 11.1 148 3 145 165 4.5 0 4.8 4.5 12/14/2005 21:00:00 14.8 0.9 17.6 12.2 14.9 0.9 17.9 12.6 14.7 1 17.2 11.8 148 4 144 165 4.4 0 4.5 4.3 12/14/2005 21:10:00 15 0.8 17.6 11.8 15.1 0.8 16.8 12.2 14.7 1.1 16.8 11.1 148 4 149 165 4.4 0 4.5 4.3 12/14/2005 21:20:00 14.8 1.2 17.2 11.5 14.9 1.2 17.2 11.8 14.5 1.3 17.6 10.7 148 5 150 165 4.4 0 4.5 4.3 12/14/2005 21:30:00 13.9 1.3 17.6 9.5 14 1.3 17.6 9.1 13.8 1.4 17.2 9.9 146 5 147 165 4.4 0 4.5 4.3 12/14/2005 21:40:00 13.2 0.9 14.9 11.1 13.3 0.8 15.3 10.7 12.9 1 15.3 9.9 143 4 145 165 4.4 0 4.5 4.5 12/14/2005 21:50:00 13.5 0.8 15.3 11.5 13.6 0.8 15.6 11.8 13.3 1.2 15.6 9.9 145 5 145 165 4.4 0 4.5 4.3 12/14/2005 22:00:00 12.7 0.8 14.9 9.9 12.8 0.9 14.9 10.3 12.3 1 14.5 9.1 143 5 145 165 4.3 0 4.5 4.3 12/14/2005 22:10:00 12.9 1 15.3 9.9 13 1 15.6 9.9 12.6 1.2 15.6 9.5 143 5 141 165 4.4 0 4.5 4.3 12/14/2005 22:20:00 12.2 1 14.9 9.5 12.3 1 15.3 9.5 12 1.2 14.9 9.1 142 5 144 165 4.4 0 4.5 4.3 12/14/2005 22:30:00 13.3 1.3 16.4 9.9 13.4 1.3 16.1 9.5 13.2 1.5 16.8 8.8 142 6 145 165 4.5 0 4.5 4.5 12/14/2005 22:40:00 13.6 1.1 16.1 9.1 13.6 1.2 16.4 9.9 13.4 1.3 17.2 9.1 142 6 141 165 4.4 0 4.5 4.3 12/14/2005 22:50:00 13 1.3 15.3 10.3 13 1.3 15.6 9.9 12.9 1.4 15.6 9.9 146 6 145 165 4.2 0.1 4.5 4.3 12/14/2005 23:00:00 12.4 0.9 14.1 9.5 12.4 0.9 14.1 9.5 12.3 1 14.1 9.5 143 5 145 165 4.1 0 4.3 4.3 12/14/2005 23:10:00 12.7 0.8 14.5 10.3 12.7 0.8 14.5 10.3 12.7 1 14.9 9.1 144 4 148 165 4 0 4.3 3.8 12/14/2005 23:20:00 11.6 0.9 13.3 9.5 11.6 0.8 13.3 9.5 11.5 0.9 13.7 9.5 145 4 149 165 3.8 0 4 3.8 12/14/2005 23:30:00 10.8 1 13.7 8 10.8 1 13.3 8 10.6 1.1 13.3 6.8 143 6 150 165 3.8 0 4 3.8 12/14/2005 23:40:00 11.3 0.7 13 9.1 11.4 0.7 13.3 9.5 11.3 0.8 13.3 9.1 145 8 142 165 3.8 0 4 3.8 12/14/2005 23:50:00 10.7 0.5 12.6 9.1 10.7 0.5 12.6 9.5 10.7 0.6 12.2 9.1 144 4 135 165 4 0 4.3 3.8 12/15/2005 00:00:00 11 0.7 12.6 8.8 10.9 0.7 12.2 8.4 10.9 0.8 12.6 8.4 144 4 143 165 4 0 4.3 3.8 12/15/2005 00:10:00 9.3 1.1 13.3 6.1 9.3 1.1 13.3 6.5 9.3 1.1 11.5 6.1 148 5 154 165 4 0 4 3.8 12/15/2005 00:20:00 9.3 1.9 14.1 6.1 9.4 1.9 14.9 5.7 9.2 1.7 13.7 6.1 146 13 132 165 4.1 0.1 4.5 3.8 12/15/2005 00:30:00 10.9 1.1 13.3 7.6 11.1 1.1 14.1 6.8 10.6 1.2 13.7 6.8 125 8 128 165 4.4 0 4.5 4.3 12/15/2005 00:40:00 12.1 1 14.5 9.5 12.3 1 14.5 9.9 11.8 1 13.7 8.4 126 6 133 165 4.6 0 4.8 4.5 12/15/2005 00:50:00 12.1 1.3 15.6 8.8 12.3 1.3 15.6 8.4 12 1.3 15.6 8.8 125 6 128 165 4.7 0 4.8 4.5 12/15/2005 01:00:00 12.8 1.2 16.1 9.1 13.1 1.2 16.1 9.5 12.6 1.3 15.6 9.1 125 6 133 165 4.7 0 4.8 4.5 12/15/2005 01:10:00 12.5 1 15.3 9.9 12.6 1 15.6 9.9 12.3 1.1 15.6 9.1 130 6 134 165 4.7 0 4.8 4.8 12/15/2005 01:20:00 12 0.9 14.9 9.5 12.1 1 14.9 9.5 11.7 1.1 14.5 8.8 130 6 133 165 4.8 0 5 4.8 12/15/2005 01:30:00 11.1 1 13.3 8.4 11.3 1 13.7 8.8 10.9 1.1 13.3 7.2 129 6 142 165 4.9 0 5 4.8 12/15/2005 01:40:00 10.8 1 13.7 8.8 11 0.9 13.7 8.8 10.7 1 13 8 125 6 115 165 4.9 0 5 4.8 12/15/2005 01:50:00 11.2 1 13.3 8.4 11.4 1 13.7 8.4 11.1 1 13.7 9.1 123 6 120 165 4.9 0 5 4.8 12/15/2005 02:00:00 11 1 13.3 8 11.2 1 13.3 7.6 10.5 1.2 13.3 7.2 117 7 126 165 4.9 0 5 4.8 12/15/2005 02:10:00 10.3 0.8 12.6 8 10.5 0.8 13 8 9.9 1 12.6 7.2 111 5 113 165 4.9 0 5 4.8 12/15/2005 02:20:00 10.2 1 12.2 8 10.4 1 12.6 7.6 9.6 1.2 12.6 5.7 103 6 104 165 4.9 0 5 4.8 12/15/2005 02:30:00 9.6 1.2 12.6 6.8 9.8 1.2 13 6.8 9.1 1.2 12.2 6.5 98 6 102 165 4.9 0 5 4.8 12/15/2005 02:40:00 10.3 0.9 12.2 7.6 10.6 0.9 12.6 8 9.6 1 12.2 6.8 96 6 102 165 4.9 0 5 4.8 12/15/2005 02:50:00 11.3 1.1 13.3 7.6 11.6 1.1 13.7 8 10.6 1.3 13.3 6.5 97 6 90 165 4.9 0 5 4.8 12/15/2005 03:00:00 11.8 1 14.5 8 12 1 15.3 8 11 1.1 14.5 8 95 6 96 165 4.9 0 5.2 4.8 12/15/2005 03:10:00 12.6 1 14.9 9.1 12.8 1 14.5 9.1 11.9 1.1 14.1 9.1 89 5 87 165 5 0 5 5 12/15/2005 03:20:00 13.2 1 14.9 9.9 13.5 1 15.3 10.3 12.6 1.1 14.5 7.6 87 5 85 165 5 0 5 5 12/15/2005 03:30:00 13 1.3 16.1 9.1 13.3 1.4 16.4 9.5 12.5 1.4 16.1 8.8 83 6 83 165 4.9 0 5 4.8 12/15/2005 03:40:00 13.8 1.6 17.6 9.1 14 1.6 17.6 9.5 13 1.5 16.8 9.1 84 7 88 165 4.8 0.1 5 4.8 12/15/2005 03:50:00 13.7 1.7 16.4 8.8 13.9 1.7 16.8 8.8 12.9 1.7 16.1 7.6 86 7 87 165 4.8 0 5 4.8 12/15/2005 04:00:00 14 1.6 17.2 10.3 14.3 1.6 17.9 10.3 13.3 1.5 16.8 9.5 83 6 73 165 4.7 0 5 4.8 12/15/2005 04:10:00 14.3 1.8 18.3 9.5 14.6 1.8 19.1 10.3 13.7 1.8 18.7 9.5 91 9 87 165 4.6 0 4.8 4.5 12/15/2005 04:20:00 13.2 1.4 17.2 9.5 13.5 1.4 17.6 9.5 12.6 1.4 16.4 8 85 7 89 165 4.7 0 4.8 4.5 12/15/2005 04:30:00 12 1.7 16.4 7.6 12.2 1.8 16.8 7.2 11.4 1.7 15.6 7.6 85 9 87 165 4.5 0 4.8 4.5 12/15/2005 04:40:00 11.8 1.7 15.6 8 12.1 1.7 16.8 7.6 11.2 1.7 16.1 8 87 9 87 165 4.4 0.1 4.5 4.3 12/15/2005 04:50:00 11.3 2.1 16.8 7.2 11.5 2.2 16.8 7.6 11 2 16.4 6.8 74 9 75 165 4.2 0 4.5 4.3 12/15/2005 05:00:00 11.9 2 16.8 7.6 12.1 2.1 17.6 7.6 11.4 2 16.8 6.8 71 10 78 165 4.4 0 4.5 4.3 12/15/2005 05:10:00 11.6 1.8 16.8 7.6 11.9 1.8 17.2 7.6 11.3 1.7 17.2 7.6 66 11 66 165 4.4 0 4.5 4.3 12/15/2005 05:20:00 9.6 1.7 14.1 5.3 9.6 1.7 14.1 5.3 9.2 1.5 13.7 6.1 59 12 48 165 4.4 0 4.5 4.3 12/15/2005 05:30:00 9.1 1.9 14.9 5.7 9.2 2 14.9 5.3 8.8 1.8 14.9 4.9 55 11 62 165 4.4 0 4.8 4.3 12/15/2005 05:40:00 9.5 1.5 14.1 6.1 9.4 1.5 14.1 5.3 9.1 1.3 14.1 5.7 35 12 47 165 4.6 0 4.8 4.5 12/15/2005 05:50:00 9.6 1.1 12.6 6.5 9.3 1.2 12.6 5.7 9.2 1.2 12.2 6.1 25 8 23 165 4.7 0 4.8 4.8 12/15/2005 06:00:00 9.6 0.9 12.6 6.8 9.4 1 12.6 5.3 9.3 1 11.8 7.2 28 6 24 165 4.8 0 5 4.8 12/15/2005 06:10:00 9.9 0.8 12.2 7.6 9.8 0.8 12.2 7.2 9.6 0.9 12.2 7.2 31 5 37 165 4.8 0 5 4.8 12/15/2005 06:20:00 8.9 0.8 11.1 6.5 8.9 0.9 11.1 6.5 8.7 0.8 11.1 6.1 32 5 34 165 4.9 0 5 4.8 12/15/2005 06:30:00 9.2 0.9 12.2 5.7 9.1 0.9 12.2 5.3 9.1 0.9 11.8 6.8 34 5 39 165 4.9 0 5 4.8 12/15/2005 06:40:00 8.4 1 11.1 5.3 8.4 1 11.5 4.9 8.2 1 10.7 5.3 37 8 36 165 5 0 5.2 5 12/15/2005 06:50:00 7.4 1.2 12.2 4.9 7.3 1.2 12.6 4.9 7.1 1.2 11.5 4.2 41 10 54 165 5.2 0 5.2 5 12/15/2005 07:00:00 6.6 1.1 10.3 3.8 6.7 1.1 10.3 3.4 6.3 1.1 9.1 3.4 47 12 49 165 5.2 0 5.5 5 12/15/2005 07:10:00 6.5 1.5 9.9 3 6.5 1.5 10.3 3 6.2 1.5 9.9 1.9 52 14 43 165 5.4 0 5.7 5.2 12/15/2005 07:20:00 7.9 1.6 11.8 3.8 8 1.7 12.6 3.4 7.6 1.5 11.8 3 61 13 72 165 5.6 0 5.7 5.5 12/15/2005 07:30:00 8.5 1.5 12.6 5.3 8.6 1.6 12.6 4.9 8.3 1.5 12.6 4.2 66 10 80 165 5.7 0 5.7 5.5 12/15/2005 07:40:00 9.3 1.6 13 5.7 9.4 1.7 13.3 5.7 9 1.5 12.6 5.7 72 9 85 165 5.7 0 6 5.7 12/15/2005 07:50:00 10.2 1.1 13 6.5 10.3 1.1 13 5.7 9.6 1.2 12.2 6.8 78 7 82 165 5.9 0 6 5.7 12/15/2005 08:00:00 9.8 1 12.2 6.5 9.9 1 12.2 6.1 9.2 1 12.2 6.5 80 6 77 165 5.9 0 6 5.7 12/15/2005 08:10:00 8.9 0.8 11.1 6.8 9.1 0.9 11.5 6.8 8.3 0.9 10.3 5.7 82 7 78 165 6.1 0 6.2 5.7 12/15/2005 08:20:00 8.3 0.8 10.3 5.3 8.5 0.8 10.3 5.7 7.8 0.9 9.9 4.9 84 6 84 165 6.1 0 6.2 6 12/15/2005 08:30:00 7.3 0.8 9.5 4.9 7.5 0.8 9.5 5.3 6.8 0.9 8.8 4.6 82 6 87 165 6.1 0 6.2 6 12/15/2005 08:40:00 7.1 0.8 9.1 4.9 7.3 0.8 9.1 4.9 6.6 0.9 8.8 4.2 81 7 81 165 6.1 0 6.2 6 12/15/2005 08:50:00 8.1 0.6 9.5 6.1 8.3 0.6 9.5 6.5 7.8 0.7 9.1 5.7 90 5 97 165 6.1 0 6.2 6 12/15/2005 09:00:00 8.8 0.5 9.9 6.5 9 0.5 10.3 6.5 8.3 0.7 9.9 5.7 96 5 93 165 6.1 0 6.2 6 12/15/2005 09:10:00 8.7 0.6 10.3 6.8 8.9 0.6 10.7 6.8 8.2 0.7 10.3 6.1 97 5 99 165 6.2 0 6.2 6 12/15/2005 09:20:00 8.6 0.8 10.3 6.5 8.8 0.8 10.7 6.5 8.1 0.9 10.7 5.3 101 6 102 165 6.2 0 6.2 6.2 12/15/2005 09:30:00 8.4 0.9 10.7 6.1 8.6 1 11.1 6.1 8 1 10.7 5.7 103 6 105 165 6.2 0 6.2 6.2 12/15/2005 09:40:00 7.7 0.8 10.3 4.9 7.9 0.8 10.7 5.3 7.3 0.9 9.5 4.9 94 7 102 165 6.3 0 6.5 6.2 12/15/2005 09:50:00 8.7 0.8 10.3 6.5 8.9 0.8 11.1 6.8 8.1 1 10.7 4.9 98 6 99 165 6.2 0 6.2 6 12/15/2005 10:00:00 9.5 0.8 11.5 6.5 9.8 0.8 12.2 6.5 8.8 1 11.1 5.3 102 6 99 165 6.2 0 6.2 6.2 12/15/2005 10:10:00 10.2 0.8 12.2 7.2 10.4 0.8 12.6 7.6 9.7 0.9 12.2 6.5 106 6 93 165 6.3 0 6.2 6.2 12/15/2005 10:20:00 9.9 0.7 12.2 8 10.1 0.7 12.2 8.4 9.6 0.8 12.2 6.8 109 6 107 165 6.3 0 6.2 6.2 12/15/2005 10:30:00 10.1 0.8 12.6 8 10.3 0.9 13 8.4 9.8 1 13 7.6 112 6 97 165 6.3 0 6.5 6.2 12/15/2005 10:40:00 10.2 1 13.3 7.6 10.3 1.1 13.7 8 9.7 1.2 13 6.5 115 6 118 165 6.4 0 6.7 6.2 12/15/2005 10:50:00 10.1 1 12.6 6.5 10.3 1 12.6 7.2 9.6 1.1 12.2 6.8 114 6 122 165 6.5 0 6.7 6.2 12/15/2005 11:00:00 10.8 0.8 12.6 8.8 10.9 0.8 13.3 9.1 10.5 0.9 12.6 8 117 5 114 165 6.5 0 6.7 6.5 12/15/2005 11:10:00 10.7 0.9 13.3 8 10.9 0.9 13.3 8 10.5 1 13 7.6 118 6 111 165 6.5 0 6.7 6.2 12/15/2005 11:20:00 10.9 1.1 13.7 8.4 11.1 1 14.1 8.8 10.8 1.1 13.7 8.4 124 8 114 165 6.5 0 6.7 6.2 12/15/2005 11:30:00 10.5 1.1 13.3 7.6 10.6 1.1 13.7 7.6 10.2 1.1 13 6.8 125 8 128 165 6.5 0 6.7 6.2 12/15/2005 11:40:00 10.3 1.2 14.1 7.2 10.4 1.2 14.1 7.6 10.1 1.4 14.1 6.5 129 9 137 165 6.6 0 6.7 6.5 12/15/2005 11:50:00 9.8 0.9 12.6 7.6 9.9 0.9 12.6 7.2 9.4 1.1 12.2 6.1 130 8 139 165 6.6 0 6.7 6.5 12/15/2005 12:00:00 10.5 1.1 13 7.6 10.5 1.1 13 7.2 10.2 1.1 13 6.5 134 8 137 165 6.6 0 6.7 6.5 12/15/2005 12:10:00 10.3 0.9 12.2 7.6 10.3 0.8 12.6 8 9.9 0.9 11.8 6.8 134 8 135 165 6.6 0 6.7 6.5 12/15/2005 12:20:00 9.9 1 12.6 7.6 9.9 1 12.6 7.2 9.5 1.1 12.2 6.5 135 7 141 165 6.5 0 6.7 6.2 12/15/2005 12:30:00 9.3 0.8 11.1 7.2 9.2 0.8 11.5 7.2 8.7 0.9 11.1 6.1 137 8 141 165 6.5 0 6.7 6.2 12/15/2005 12:40:00 9.4 1 11.5 6.8 9.4 1 11.5 6.8 9 1 11.8 6.8 136 6 145 165 6.4 0 6.7 6.2 12/15/2005 12:50:00 9.8 0.8 12.2 7.6 9.8 0.8 11.8 7.2 9.5 0.8 11.1 7.2 139 8 126 165 6.4 0 6.7 6.2 12/15/2005 13:00:00 10.2 1.1 13.3 7.2 10.2 1.1 13.3 7.2 10 1.2 12.6 7.2 139 6 143 165 6.3 0 6.7 6.2 12/15/2005 13:10:00 10.6 0.9 13 8 10.6 0.9 13 8 10.3 1.1 13 6.5 139 7 142 165 6.3 0 6.5 6.2 12/15/2005 13:20:00 10.2 0.9 13.3 7.2 10.2 0.9 13.3 7.2 9.8 1 12.6 6.8 136 8 133 165 6.3 0 6.5 6.2 12/15/2005 13:30:00 10 1.2 13 6.8 9.9 1.2 13 7.2 9.5 1.3 13 6.8 137 9 128 165 6.3 0 6.5 6.2 12/15/2005 13:40:00 10.6 1 13.7 7.6 10.6 1 13.7 7.6 10.2 1.1 13 7.2 139 8 140 165 6.3 0 6.5 6.2 12/15/2005 13:50:00 10.9 1.3 14.1 7.2 10.9 1.3 14.1 7.6 10.6 1.3 13.7 6.5 139 8 148 165 6.3 0 6.2 6.2 12/15/2005 14:00:00 10.6 1 14.1 8 10.7 1.1 13.3 8 10.4 1.2 13.3 6.5 139 8 137 165 6.3 0 6.2 6.2 12/15/2005 14:10:00 11.4 1 13.7 7.6 11.4 1 13.7 8 10.9 1.1 13.3 7.6 139 8 138 165 6.3 0 6.2 6.2 12/15/2005 14:20:00 11.8 1.3 15.3 8.8 11.8 1.3 16.1 7.6 11.3 1.5 14.1 6.8 140 7 129 165 6.2 0 6.2 6.2 12/15/2005 14:30:00 12.2 1.1 16.1 9.5 12.2 1.1 15.6 9.1 12 1.2 15.3 8.4 141 8 129 165 6.2 0 6.2 6.2 12/15/2005 14:40:00 12.5 1.1 14.9 8.4 12.5 1.1 14.9 8.4 12.2 1.2 14.9 7.6 143 7 145 165 6.2 0 6.2 6 12/15/2005 14:50:00 12.7 1 15.6 9.5 12.7 1 15.6 9.1 12.4 1.2 15.6 8.8 143 6 143 165 6.2 0 6.2 6 12/15/2005 15:00:00 13.5 0.8 15.6 11.5 13.4 0.7 15.3 11.8 13.4 1 16.1 9.5 144 4 144 165 6.2 0 6.2 6 12/15/2005 15:10:00 12.2 1 14.9 9.5 12.1 1 14.5 9.5 12 1.1 14.5 8.4 146 5 150 165 6.2 0 6.2 6 12/15/2005 15:20:00 11.3 0.9 13.7 9.5 11.2 0.8 13.7 9.5 11.2 0.8 13.3 9.5 147 5 144 165 6.2 0 6.2 6 12/15/2005 15:30:00 11.5 0.8 13.7 9.5 11.4 0.8 13.3 9.9 11.3 0.8 13 8.8 147 5 144 165 6.2 0 6.2 6 12/15/2005 15:40:00 11 1.1 14.5 8.8 10.9 1 13.7 8.8 10.9 1 14.1 8.4 145 7 150 165 6.1 0 6.2 6 12/15/2005 15:50:00 13.2 1.1 16.4 9.9 13.2 1.2 16.4 9.9 13 1.2 16.1 9.9 141 6 138 165 6.3 0 6.2 6 12/15/2005 16:00:00 13.6 1.2 16.4 10.3 13.6 1.3 16.8 10.3 13.4 1.3 16.4 9.9 140 7 145 165 6.3 0 6.5 6.2 12/15/2005 16:10:00 13.2 1.1 16.1 9.5 13.1 1.2 16.1 9.5 12.7 1.4 16.8 8.8 141 8 128 165 6.4 0 6.5 6.2 12/15/2005 16:20:00 14.7 1.4 18.3 10.7 14.8 1.5 18.3 10.7 14.5 1.4 17.6 9.9 140 6 125 165 6.4 0 6.5 6.2 12/15/2005 16:30:00 15.1 1.4 19.1 11.8 15.2 1.4 19.1 11.8 14.8 1.6 18.7 10.7 139 8 135 165 6.4 0 6.7 6.2 12/15/2005 16:40:00 15.4 1.1 18.3 11.5 15.5 1.2 18.7 11.5 15 1.2 17.9 11.5 140 6 148 165 6.4 0 6.7 6.2 12/15/2005 16:50:00 15.4 1.5 19.5 11.8 15.4 1.6 19.5 11.8 15 1.8 19.5 10.7 140 6 143 165 6.4 0 6.7 6.2 12/15/2005 17:00:00 15.2 1.2 17.9 12.6 15.2 1.2 18.3 12.6 14.9 1.3 19.5 11.1 142 6 133 165 6.4 0 6.7 6.2 12/15/2005 17:10:00 15.6 1.7 20.2 11.1 15.7 1.7 19.9 11.5 15.4 1.8 21.4 10.7 141 7 145 165 6.3 0 6.5 6.2 12/15/2005 17:20:00 17.3 1.3 20.2 13 17.4 1.4 21 13 17.2 1.5 20.6 12.2 141 6 129 165 6.3 0 6.5 6.2 12/15/2005 17:30:00 17.2 1.3 20.6 12.2 17.2 1.4 20.6 11.8 17.2 1.5 21.4 12.2 143 6 135 165 6.3 0 6.5 6.2 12/15/2005 17:40:00 16.6 1.2 20.6 13.3 16.7 1.2 21 13.7 16.3 1.4 20.6 12.6 144 6 132 165 6.3 0 6.2 6.2 12/15/2005 17:50:00 18.1 1.4 21 14.5 18.1 1.3 20.6 14.5 18.1 1.6 21.8 14.1 145 5 154 165 6.2 0 6.2 6.2 12/15/2005 18:00:00 17.7 1.3 22.6 13.7 17.7 1.3 22.6 13.7 17.4 1.5 22.1 12.6 146 5 148 165 6.3 0 6.2 6.2 12/15/2005 18:10:00 16.6 1 19.1 13.7 16.5 1 18.7 13.7 16.1 1.2 18.7 12.2 149 4 148 165 6.2 0 6.2 6 12/15/2005 18:20:00 16 1.3 19.1 12.6 16 1.3 19.1 13 15.6 1.5 19.9 11.5 147 5 135 165 6.2 0 6.2 6 12/15/2005 18:30:00 16.9 1.2 19.5 14.1 16.9 1.2 19.5 14.1 16.5 1.2 19.5 13.3 148 5 148 165 6.1 0 6.2 6 12/15/2005 18:40:00 17.8 1 20.2 14.9 17.8 1 20.6 14.9 17.4 1.2 20.2 13.7 147 4 145 165 6.1 0 6.2 6 12/15/2005 18:50:00 17.2 1 19.9 14.1 17.3 1 19.5 14.5 17 1 19.9 12.2 146 5 146 165 6.1 0 6.2 6 12/15/2005 19:00:00 18 1.2 21.4 14.5 18.1 1.1 21 14.9 17.7 1.2 20.6 13.7 148 4 151 165 6.1 0 6.2 6 12/15/2005 19:10:00 18.5 1.2 21 14.9 18.5 1.2 21.4 14.9 18.1 1.4 20.6 13.7 147 4 150 165 6.1 0 6 6 12/15/2005 19:20:00 19.5 1.4 22.9 16.1 19.5 1.3 22.6 16.4 19 1.7 22.6 14.9 145 4 148 165 6 0 6 6 12/15/2005 19:30:00 19.4 1.3 22.9 15.6 19.5 1.2 22.9 16.1 19.2 1.3 22.6 15.3 147 4 148 165 6 0 6 5.7 12/15/2005 19:40:00 21.8 2 27.1 16.8 21.9 2 26.8 16.8 21.4 2.3 27.1 15.3 149 5 148 165 6 0 6 6 12/15/2005 19:50:00 21 1.6 24.8 17.2 21 1.5 24.8 16.8 20.7 1.7 24.8 16.1 151 7 147 165 5.9 0 6 5.7 12/15/2005 20:00:00 19.8 1.5 22.9 16.1 19.8 1.5 22.6 16.4 19.6 1.7 24.4 14.9 152 5 160 165 5.8 0 6 5.7 12/15/2005 20:10:00 18.6 1.4 22.6 14.9 18.7 1.3 22.1 14.5 18.3 1.5 22.1 14.1 149 5 153 165 5.7 0 5.7 5.5 12/15/2005 20:20:00 17.1 1.3 20.2 13.3 17 1.2 20.2 13.3 17.1 1.4 20.6 13.3 158 17 150 165 5.6 0 5.7 5.5 12/15/2005 20:30:00 17.6 1.3 21.4 13 17.5 1.3 21 11.8 17.4 1.5 21 13.3 157 8 157 165 5.2 0 5.5 5 12/15/2005 20:40:00 18.9 1.4 22.6 15.6 18.8 1.4 22.9 15.6 18.7 1.5 22.9 14.5 158 15 154 165 4.9 0 5 4.8 12/15/2005 20:50:00 19.4 1.1 22.9 16.4 19.4 1.1 22.9 15.6 19.3 1.2 22.1 14.9 152 4 150 165 4.8 0 5 4.8 12/15/2005 21:00:00 18.6 1.1 21 15.6 18.7 1 21 15.6 18.4 1.4 21.4 13.3 150 3 150 165 4.7 0 4.8 4.8 12/15/2005 21:10:00 18.3 1.1 21.4 15.3 18.3 1.1 21.8 14.9 18.3 1.2 21.8 14.9 152 5 153 165 4.6 0 4.8 4.5 12/15/2005 21:20:00 18.1 1.3 21.4 14.5 18.1 1.3 21.4 14.5 18.1 1.5 21.8 13 152 5 156 165 4.6 0 4.8 4.5 12/15/2005 21:30:00 16.4 0.9 19.1 13.7 16.5 0.9 19.5 14.5 16.5 1 19.1 13 152 3 157 165 4.6 0 4.8 4.5 12/15/2005 21:40:00 14.8 1 17.9 12.2 14.8 1 17.6 12.6 14.7 1.2 17.6 10.3 153 4 159 165 4.5 0 4.8 4.5 12/15/2005 21:50:00 14.9 1.2 17.9 12.2 14.8 1.1 17.9 11.8 15.1 1.2 18.7 11.8 157 5 161 165 4.5 0 4.8 4.5 12/15/2005 22:00:00 12.8 1.2 15.6 9.1 12.7 1.2 15.6 9.1 12.8 1.4 15.6 9.1 153 5 154 165 4.5 0 5 4.5 12/15/2005 22:10:00 13.4 1.1 16.4 10.3 13.3 1.1 16.4 10.7 13.5 1.1 16.8 10.3 150 5 148 165 4.5 0 4.8 4.5 12/15/2005 22:20:00 14.3 0.6 16.1 12.2 14.3 0.6 16.1 12.6 14.1 0.9 16.1 10.7 151 2 153 165 4.5 0 4.5 4.5 12/15/2005 22:30:00 13.8 0.9 15.6 11.5 13.8 0.9 15.6 11.1 13.6 1 15.6 10.7 149 3 151 165 4.4 0 4.5 4.3 12/15/2005 22:40:00 12.4 0.8 14.5 10.7 12.4 0.8 14.9 10.7 12.1 0.9 14.5 9.5 149 5 147 165 4.4 0 4.5 4.3 12/15/2005 22:50:00 11.7 0.6 13.3 9.1 11.8 0.6 13.3 9.1 11.5 0.7 13 8.8 147 4 148 165 4.3 0 4.5 4.3 12/15/2005 23:00:00 11.4 0.6 12.6 9.9 11.4 0.6 13 9.9 11.4 0.7 13 9.1 148 5 162 165 4.3 0 4.5 4.3 12/15/2005 23:10:00 11.7 0.7 13.7 9.9 11.6 0.7 13.7 9.9 11.6 0.9 13.7 9.1 148 5 152 165 4.1 0 4.3 4.3 12/15/2005 23:20:00 10.8 0.6 13 8.8 10.8 0.6 12.6 9.1 10.8 0.6 12.6 8.8 148 4 147 165 4.1 0 4.3 4.3 12/15/2005 23:30:00 10.9 0.7 12.2 8.8 10.9 0.7 12.2 8.8 10.9 0.8 12.6 8.8 150 3 146 165 4.2 0 4.5 4.3 12/15/2005 23:40:00 10.7 0.5 11.8 8.8 10.7 0.5 11.8 8.8 10.7 0.7 12.2 8 149 3 149 165 4.1 0 4.3 4.3 12/15/2005 23:50:00 10.4 0.6 11.5 8.8 10.3 0.6 11.5 8.4 10.6 0.6 11.8 9.1 155 4 156 165 4.1 0 4.3 4.3 12/16/2005 00:00:00 8.6 0.6 10.3 6.5 8.4 0.7 9.9 6.1 8.9 0.6 10.3 6.8 159 4 154 165 4.1 0 4.3 4.3 12/16/2005 00:10:00 7.7 0.4 9.1 6.5 7.4 0.4 8.4 6.5 7.9 0.4 9.1 6.8 163 4 162 165 4.1 0 4.3 4 12/16/2005 00:20:00 7.7 0.6 9.1 6.1 7.4 0.5 9.1 6.1 7.7 0.6 9.1 6.5 166 12 162 165 4 0 4.3 3.8 12/16/2005 00:30:00 7.6 0.6 9.1 6.1 7.3 0.5 8.8 6.1 7.6 0.5 9.1 6.5 169 9 173 165 4 0 4.3 3.8 12/16/2005 00:40:00 8 0.5 9.5 6.5 7.6 0.5 8.8 6.8 8 0.5 9.1 6.8 167 7 165 165 4 0 4.3 3.8 12/16/2005 00:50:00 7.4 0.6 8.8 5.7 7 0.6 8.4 5.3 7.4 0.6 8.8 6.1 166 8 166 165 4 0 4.3 3.8 12/16/2005 01:00:00 6.9 0.5 8.8 5.7 6.7 0.4 8 5.7 7.1 0.4 8 6.1 165 7 173 165 4 0 4.3 3.8 12/16/2005 01:10:00 7.8 0.5 9.1 6.1 7.6 0.5 9.1 6.1 8 0.5 9.1 6.5 161 6 167 165 4 0 4.3 3.8 12/16/2005 01:20:00 8.2 0.7 10.3 6.5 8 0.6 9.9 6.8 8.3 0.6 10.3 7.2 164 8 166 165 4 0 4.3 3.8 12/16/2005 01:30:00 9 0.7 11.1 7.6 8.7 0.7 10.7 7.2 9 0.7 11.5 7.6 167 12 165 165 4 0 4.3 3.8 12/16/2005 01:40:00 9 0.6 11.1 7.6 8.7 0.5 10.3 7.2 9 0.6 10.7 7.6 167 11 165 165 3.9 0 4 3.8 12/16/2005 01:50:00 8.7 0.5 9.9 7.2 8.4 0.5 9.5 6.8 8.8 0.5 9.9 7.2 169 16 167 165 3.9 0 4 3.8 12/16/2005 02:00:00 8.3 0.5 9.5 6.1 8 0.5 9.1 6.1 8.3 0.6 9.9 6.1 166 14 166 165 4 0 4 3.8 12/16/2005 02:10:00 7.9 0.3 8.8 6.8 7.7 0.3 8.8 6.8 8 0.4 8.8 6.5 167 17 165 165 3.9 0 4.3 3.8 12/16/2005 02:20:00 6.9 0.5 8 5.7 6.8 0.5 8 5.3 7 0.6 8.4 5.3 160 6 165 165 4 0 4 3.8 12/16/2005 02:30:00 6.4 0.5 7.6 5.3 6.3 0.4 7.6 5.3 6.5 0.5 8 4.9 162 9 161 165 3.9 0 4 3.8 12/16/2005 02:40:00 7.2 0.6 8.4 5.7 7 0.6 8 5.7 7.3 0.6 8.4 5.3 167 13 167 165 3.8 0 4 3.8 12/16/2005 02:50:00 6.9 0.4 8 5.7 6.7 0.4 7.6 5.7 6.9 0.5 8.4 5.7 167 4 166 165 3.8 0 4 3.8 12/16/2005 03:00:00 7.3 0.5 8.4 5.3 7.1 0.5 8 5.7 7.3 0.6 8.8 5.7 167 7 165 165 3.8 0 4 3.8 12/16/2005 03:10:00 7.2 0.4 8.4 5.7 6.9 0.4 8 5.7 7.2 0.5 8.4 5.7 170 11 165 165 3.8 0 4 3.8 12/16/2005 03:20:00 7.3 0.5 8.4 6.1 7 0.4 8 5.7 7.5 0.5 8.4 5.7 167 8 171 165 3.8 0 4 3.8 12/16/2005 03:30:00 7.4 0.4 8.4 6.5 7.1 0.4 8 6.1 7.6 0.4 8.4 6.8 170 10 166 165 3.8 0 4 3.8 12/16/2005 03:40:00 7.3 0.4 8.8 6.1 7 0.4 8.4 6.1 7.3 0.4 8.8 6.5 166 13 165 165 3.9 0 4 3.8 12/16/2005 03:50:00 7.4 0.6 8.8 6.1 7.1 0.5 8.4 5.7 7.3 0.6 9.1 6.1 166 9 166 165 3.8 0 4 3.8 12/16/2005 04:00:00 7.7 0.5 9.1 6.5 7.3 0.4 8.4 6.1 7.6 0.5 9.1 6.1 165 9 165 165 3.8 0 4 3.8 12/16/2005 04:10:00 7.9 0.4 9.1 6.8 7.6 0.3 8.8 6.8 7.9 0.4 9.1 6.5 166 8 164 165 3.8 0 4 3.5 12/16/2005 04:20:00 7 0.6 8 5.7 6.7 0.5 8 5.3 7.1 0.6 8.4 5.3 166 9 165 165 3.8 0 3.8 3.5 12/16/2005 04:30:00 5.5 0.4 6.5 4.6 5.3 0.4 6.1 4.6 5.5 0.5 6.5 4.6 166 13 166 165 3.8 0 4 3.5 12/16/2005 04:40:00 4.8 0.4 5.7 3.8 4.7 0.3 5.7 3.8 4.9 0.4 5.7 3.8 167 8 165 165 3.8 0 4 3.8 12/16/2005 04:50:00 5.4 0.4 6.5 4.6 5.1 0.4 6.1 4.2 5.4 0.4 6.5 4.6 169 3 171 165 3.8 0 4 3.5 12/16/2005 05:00:00 5.8 0.6 7.6 4.6 5.6 0.6 7.2 4.6 5.8 0.6 8 4.9 170 4 175 165 3.8 0 4 3.8 12/16/2005 05:10:00 6.5 0.5 8 5.3 6.2 0.5 7.2 4.9 6.4 0.4 7.6 5.3 167 6 168 165 3.8 0 4 3.8 12/16/2005 05:20:00 6 0.5 7.2 4.6 5.7 0.4 6.5 4.6 6 0.4 7.2 4.9 159 6 164 165 3.8 0 4 3.8 12/16/2005 05:30:00 5.2 0.5 6.1 3.8 5.1 0.5 6.5 3.8 5.2 0.5 6.5 3 150 7 151 165 3.8 0 4 3.8 12/16/2005 05:40:00 4.4 0.5 5.7 3.4 4.3 0.5 5.3 3.4 4.5 0.6 6.5 3.4 154 5 155 165 3.8 0 4 3.8 12/16/2005 05:50:00 4.4 0.5 5.7 3 4.2 0.5 5.3 3 4.4 0.4 5.7 3.4 162 5 158 165 3.9 0 4 3.8 12/16/2005 06:00:00 4.9 0.4 5.7 3.4 4.8 0.4 5.7 3.4 5 0.4 6.1 3.8 152 4 157 165 3.9 0 4 3.8 12/16/2005 06:10:00 5 0.5 6.1 3.8 4.8 0.4 5.7 3.4 5 0.4 6.1 3.8 153 5 164 165 3.9 0 4 3.8 12/16/2005 06:20:00 4.6 0.5 6.1 3 4.5 0.4 5.7 3 4.6 0.5 5.7 3.4 149 10 152 165 3.9 0 4 3.8 12/16/2005 06:30:00 4.6 0.5 5.7 3.4 4.5 0.4 5.7 3.4 4.7 0.5 6.1 3 151 6 153 165 3.9 0 4 3.8 12/16/2005 06:40:00 4.8 0.4 6.1 3.8 4.7 0.4 6.1 3.8 4.8 0.4 6.1 3.8 147 6 146 165 3.8 0 4 3.8 12/16/2005 06:50:00 4.7 0.3 5.3 3.8 4.5 0.2 4.9 3.8 4.8 0.3 5.3 4.2 154 3 155 165 3.8 0 4 3.8 12/16/2005 07:00:00 4.6 0.4 5.7 3.8 4.5 0.4 5.7 3.8 4.7 0.3 5.7 3.8 150 6 151 165 3.8 0 4 3.8 12/16/2005 07:10:00 4.6 0.4 5.7 3.4 4.5 0.4 5.7 3.4 4.7 0.3 5.3 3.8 149 7 134 165 3.8 0 4 3.8 12/16/2005 07:20:00 4.2 0.4 4.9 3.4 4.1 0.4 4.9 3 4.3 0.3 4.9 3 153 3 157 165 3.8 0 4 3.8 12/16/2005 07:30:00 3.2 0.3 4.2 2.3 3.1 0.4 4.2 2.3 3.4 0.3 4.6 2.6 153 7 148 165 3.8 0 4 3.8 12/16/2005 07:40:00 2.9 0.5 4.2 1.1 2.7 0.5 3.8 1.5 3 0.5 4.2 1.9 163 5 160 165 3.8 0 4 3.8 12/16/2005 07:50:00 1.8 0.4 2.6 0.7 1.7 0.4 2.6 0.7 2.1 0.3 3 1.5 164 7 162 165 3.8 0 4 3.8 12/16/2005 08:00:00 1.4 0.4 2.3 0.4 1.4 0.3 1.9 0.4 1.8 0.3 2.6 1.1 161 4 164 165 3.8 0 4 3.5 12/16/2005 08:10:00 1.6 0.4 2.6 0.4 1.5 0.3 2.3 0.7 1.9 0.2 2.6 1.1 165 5 163 165 3.8 0 4 3.5 12/16/2005 08:20:00 1.7 0.3 2.3 1.1 1.6 0.3 2.3 0.7 2 0.3 2.6 1.1 150 9 146 165 3.8 0 4 3.5 12/16/2005 08:30:00 1.9 0.4 2.6 0.4 1.8 0.4 2.6 0.4 2.1 0.2 2.6 1.5 154 5 150 165 3.8 0 4 3.8 12/16/2005 08:40:00 1.6 0.3 2.3 0.7 1.5 0.3 2.3 0.7 1.9 0.2 2.6 1.5 151 7 156 165 3.8 0 3.8 3.5 12/16/2005 08:50:00 2.2 0.4 3 1.1 2 0.4 2.6 1.1 2.2 0.3 3 1.5 161 4 159 165 3.8 0 3.8 3.5 12/16/2005 09:00:00 2.4 0.3 3 1.9 2.2 0.3 3 1.5 2.4 0.2 2.6 1.9 157 3 158 165 3.8 0 3.8 3.5 12/16/2005 09:10:00 2.2 0.3 2.6 1.5 2 0.3 2.6 1.1 2.3 0.2 2.6 1.9 157 3 158 165 3.8 0 3.8 3.5 12/16/2005 09:20:00 2.1 0.3 3 1.1 1.9 0.3 2.6 1.1 2.3 0.3 3 1.9 156 6 150 165 3.8 0 4 3.8 12/16/2005 09:30:00 1.9 0.3 2.6 0.7 1.7 0.4 2.3 0.4 2 0.3 2.6 0.7 159 4 161 165 3.8 0 4 3.8 12/16/2005 09:40:00 1.9 0.2 2.3 1.1 1.7 0.3 2.3 1.1 2 0.2 2.6 1.5 155 4 162 165 3.8 0 3.8 3.8 12/16/2005 09:50:00 1.6 0.4 2.3 0.4 1.5 0.4 2.3 0.4 1.7 0.2 2.3 1.1 154 6 158 165 3.8 0 4 3.8 12/16/2005 10:00:00 2.1 0.3 2.6 1.1 1.9 0.3 2.3 1.1 2.2 0.3 2.6 1.5 149 4 151 165 3.8 0 3.8 3.8 12/16/2005 10:10:00 2 0.4 2.6 0.7 1.7 0.4 2.6 0.4 2 0.4 2.6 0.7 149 6 148 165 3.8 0 3.8 3.8 12/16/2005 10:20:00 1.5 0.5 2.6 0.4 1.3 0.5 2.6 0.4 1.6 0.4 2.6 0.7 151 6 148 165 3.8 0 3.8 3.8 12/16/2005 10:30:00 1.5 0.6 2.6 0.4 1.3 0.5 2.6 0.4 1.6 0.5 2.6 0.4 161 9 161 165 3.8 0 4 3.5 12/16/2005 10:40:00 1.1 0.7 2.6 0.4 1 0.7 2.6 0.4 1.3 0.6 2.6 0.4 179 16 178 165 3.6 0 3.8 3.5 12/16/2005 10:50:00 1 0.5 2.3 0.4 0.8 0.5 2.3 0.4 1.4 0.5 2.3 0.4 196 13 194 165 3.5 0 3.8 3.5 12/16/2005 11:00:00 1 0.4 1.9 0.4 0.9 0.4 1.9 0.4 1.5 0.3 2.6 0.7 194 5 188 165 3.5 0 3.8 3.3 12/16/2005 11:10:00 0.7 0.4 1.5 0.4 0.7 0.4 1.5 0.4 1.2 0.3 1.9 0.7 186 5 192 165 3.5 0 3.5 3.5 12/16/2005 11:20:00 0.5 0.3 1.5 0.4 0.4 0.1 1.1 0.4 1.1 0.3 1.5 0.4 191 4 188 165 3.5 0 3.5 3.5 12/16/2005 11:30:00 0.4 0.1 1.1 0.4 0.4 0 0.4 0.4 0.8 0.3 1.5 0.4 204 3 204 165 3.5 0 3.5 3.5 12/16/2005 11:40:00 0.9 0.5 1.9 0.4 1.1 0.5 1.9 0.4 1.3 0.5 2.3 0.4 232 9 238 165 3.3 0.1 3.5 3 12/16/2005 11:50:00 0.9 0.4 1.9 0.4 1.4 0.3 1.9 0.7 1.5 0.3 2.3 0.7 262 7 268 165 3 0 3.3 2.8 12/16/2005 12:00:00 1.3 0.2 1.9 0.7 1.3 0.2 1.9 0.7 1.5 0.2 1.9 0.7 273 1 271 165 3 0 3.3 3 12/16/2005 12:10:00 1.9 0.5 3 0.7 1.9 0.5 3 0.7 1.4 0.6 2.6 0.4 284 5 287 165 3.2 0 3.3 3 12/16/2005 12:20:00 2.5 0.8 4.2 0.4 2.5 0.8 4.6 0.7 2.3 0.8 4.6 0.4 279 5 281 165 3.2 0 3.3 3 12/16/2005 12:30:00 3.7 0.5 4.9 1.9 3.7 0.5 4.9 2.3 3.5 0.5 4.6 1.5 282 5 286 165 3.2 0 3.3 3 12/16/2005 12:40:00 3.7 0.5 4.9 2.3 3.6 0.5 5.3 2.6 3 0.6 4.6 1.9 297 7 313 165 3.2 0 3.5 3.3 12/16/2005 12:50:00 4.2 0.8 5.7 2.6 4.1 0.7 5.7 2.6 3.1 0.6 4.9 1.9 298 6 293 165 3.4 0 3.5 3.3 12/16/2005 13:00:00 5 0.4 6.1 4.2 5 0.4 6.1 4.2 3.7 0.5 5.7 2.6 297 4 292 165 3.5 0 3.5 3.5 12/16/2005 13:10:00 5.4 0.7 6.8 3.8 5.3 0.7 6.8 3.8 4.2 0.6 5.7 2.6 302 5 301 165 3.5 0 3.5 3.5 12/16/2005 13:20:00 5.3 0.6 6.8 3.8 5.2 0.5 6.8 3.8 4.3 0.5 5.3 2.3 303 6 301 165 3.5 0 3.5 3.5 12/16/2005 13:30:00 5 0.7 6.8 3 4.9 0.6 6.8 3.4 4 0.7 6.1 2.3 303 6 305 165 3.4 0 3.5 3.3 12/16/2005 13:40:00 3.4 0.8 5.3 2.3 3.4 0.8 5.3 2.3 3.3 0.7 5.3 1.9 315 8 297 165 3.4 0 3.5 3.3 12/16/2005 13:50:00 2.2 0.8 3.8 0.4 2.2 0.8 3.8 0.4 1.9 0.8 3.4 0.4 305 9 292 165 3.4 0 3.5 3.3 12/16/2005 14:00:00 2.9 0.9 4.6 1.1 2.9 0.9 4.9 1.1 2.1 0.8 4.6 0.7 297 7 300 165 3.3 0 3.5 3.3 12/16/2005 14:10:00 4.1 0.9 6.1 1.9 4.2 0.9 6.5 1.9 3.3 0.9 6.8 1.5 294 8 287 165 3 0 3.3 3 12/16/2005 14:20:00 2 1 4.2 0.4 1.9 1.1 4.6 0.4 1.9 0.9 4.2 0.4 334 22 301 165 3.1 0 3.3 3 12/16/2005 14:30:00 1.4 0.9 3.8 0.4 1.4 0.9 3.8 0.4 1.3 0.7 2.6 0.4 318 27 295 165 3.2 0 3.5 3.3 12/16/2005 14:40:00 2.2 1.3 5.3 0.4 2.2 1.4 5.3 0.4 1.8 1.1 4.2 0.4 320 38 297 165 3.2 0 3.5 3 12/16/2005 14:50:00 6.9 1.5 9.9 3 6.8 1.5 9.9 3 5.4 1.3 8.4 2.3 294 5 296 165 3 0 3.3 2.8 12/16/2005 15:00:00 8.5 0.8 11.1 5.7 8.4 0.8 10.7 5.7 6.5 1.2 9.9 4.6 302 7 309 165 3 0 3 2.8 12/16/2005 15:10:00 6.9 0.9 9.1 4.6 6.7 0.8 9.1 4.9 6 0.9 8.4 3.8 309 8 309 165 2.9 0 3 2.8 12/16/2005 15:20:00 7.7 1 9.5 4.9 7.5 1 9.1 4.6 6.5 1 9.1 4.2 309 8 308 165 3 0 3.3 2.8 12/16/2005 15:30:00 7.1 0.9 9.1 4.6 6.9 0.9 8.8 4.2 6.2 0.8 8.4 3.4 316 9 309 165 3.3 0.1 3.5 3 12/16/2005 15:40:00 6.9 1 9.1 4.9 6.8 1 8.8 4.6 5.7 1 8.4 3 308 6 308 165 3.3 0 3.5 3.3 12/16/2005 15:50:00 8 0.9 9.9 4.9 7.9 0.9 9.5 4.9 6.5 1 8.4 3.4 306 5 305 165 3 0 3.3 2.8 12/16/2005 16:00:00 6.7 1 9.1 3.8 6.6 1 8.8 3.4 5.1 1.3 8.4 0.7 304 8 291 165 2.9 0 3 2.8 12/16/2005 16:10:00 6.1 1 8.8 3.4 6 1 8 3 5 1 6.8 1.5 307 8 294 165 2.9 0 3 2.8 12/16/2005 16:20:00 5.5 1 8 3 5.4 1 7.6 3 4.1 1.2 7.2 0.4 304 9 308 165 2.9 0 3 2.8 12/16/2005 16:30:00 6.1 1.3 9.5 3.4 6 1.3 9.1 3 4.6 1.1 7.2 1.9 306 9 304 165 2.9 0 3 2.8 12/16/2005 16:40:00 6.9 1.1 9.5 3.8 6.8 1.1 9.1 3.8 5.4 1.3 8 2.3 305 8 294 165 2.9 0 3 2.8 12/16/2005 16:50:00 7 1.3 9.9 3.4 6.8 1.3 9.5 3 5.6 1.3 8.8 2.3 304 9 305 165 2.9 0 3 2.8 12/16/2005 17:00:00 7.9 0.9 9.5 4.9 7.7 0.9 9.5 4.6 6.3 1 9.1 3.4 304 6 302 165 2.9 0 3 2.8 12/16/2005 17:10:00 7.6 0.7 9.1 5.3 7.5 0.8 9.1 4.2 6.3 0.8 8.4 3.4 306 6 308 165 2.9 0 3 2.8 12/16/2005 17:20:00 7.8 0.9 9.9 5.3 7.7 0.8 9.5 5.3 6.2 1.1 8.8 3 305 5 306 165 2.9 0 3 2.8 12/16/2005 17:30:00 9 1.2 11.8 5.7 8.9 1.1 11.8 5.7 7.6 1.1 10.7 4.2 307 6 305 165 3 0 3 2.8 12/16/2005 17:40:00 7.5 1.3 10.3 3.8 7.5 1.4 10.3 3.4 6.1 1.7 9.9 2.6 310 9 309 165 2.9 0 3 2.8 12/16/2005 17:50:00 7.2 1.1 10.3 4.2 7.1 1.1 9.9 3.8 5.3 1.2 8.4 2.3 308 10 313 165 2.9 0 3 2.8 12/16/2005 18:00:00 7.8 1 9.9 4.6 7.8 1 10.3 4.2 6 1.2 8.8 3 306 8 302 165 2.8 0 2.8 2.8 12/16/2005 18:10:00 8.5 0.9 10.3 6.1 8.5 0.9 10.7 5.7 6.8 1.2 9.9 3.8 306 5 312 165 2.8 0 2.8 2.8 12/16/2005 18:20:00 9.9 0.9 12.6 7.2 9.8 0.8 11.8 7.6 8.4 1.1 11.1 5.3 306 6 290 165 2.9 0 3 2.8 12/16/2005 18:30:00 10.9 0.9 13 8.8 10.7 0.9 12.6 8.4 8.7 1.1 12.2 6.1 305 4 308 165 2.9 0 3 2.8 12/16/2005 18:40:00 10.8 0.8 13 8 10.7 0.8 13 8 8.2 1.1 11.5 5.3 301 6 305 165 2.9 0 3 2.8 12/16/2005 18:50:00 12.9 0.8 14.9 10.3 12.8 0.8 14.9 10.3 9.1 1.1 13.7 6.8 299 4 298 165 2.9 0 3 2.8 12/16/2005 19:00:00 13.2 1 15.3 9.9 13.1 1 14.9 9.9 10.1 1.1 13 7.2 305 4 304 165 2.9 0 3 2.8 12/16/2005 19:10:00 13.4 1.1 15.6 11.1 13.3 1.1 16.1 10.3 10.5 1.2 14.1 7.2 306 4 303 165 2.9 0 3 2.8 12/16/2005 19:20:00 14 1 16.4 11.1 13.9 1.1 16.1 10.7 11.3 1.4 14.9 7.6 306 4 305 165 2.9 0 3 2.8 12/16/2005 19:30:00 13.5 1 16.1 9.9 13.4 1 15.6 9.9 10.9 1.4 14.9 7.2 306 5 301 165 2.9 0 3 2.8 12/16/2005 19:40:00 14.1 0.8 15.6 11.5 14 0.8 15.6 11.8 12.6 1.2 15.3 8.8 309 4 307 165 2.9 0 3 2.8 12/16/2005 19:50:00 14.2 1 16.4 11.1 14.1 1 16.4 10.7 13.3 1.1 15.6 9.5 312 4 310 165 2.9 0 3 2.8 12/16/2005 20:00:00 14 0.7 15.6 11.8 13.9 0.7 15.6 11.5 12.5 0.9 14.5 9.5 310 4 308 165 2.9 0 3 2.8 12/16/2005 20:10:00 12.8 0.8 14.5 10.3 12.6 0.8 14.5 9.9 11.9 1.1 14.5 8.8 312 3 313 165 2.9 0 3 2.8 12/16/2005 20:20:00 13 0.8 14.9 10.3 12.9 0.8 14.5 9.9 11.3 1 13.3 7.2 309 4 307 165 2.9 0 3 2.8 12/16/2005 20:30:00 12.9 0.7 14.5 10.7 12.7 0.7 14.1 10.7 11.1 1 13 8 310 3 308 165 2.9 0 3 2.8 12/16/2005 20:40:00 12.6 0.7 14.5 9.9 12.4 0.7 14.9 9.9 10.9 0.9 13 8.4 310 3 307 165 2.9 0 3 2.8 12/16/2005 20:50:00 12.1 0.8 14.5 9.9 12 0.8 14.5 9.5 10.5 1 13 7.2 310 4 307 165 3 0 3 2.8 12/16/2005 21:00:00 11.6 0.7 13.3 9.1 11.6 0.7 13.3 8.8 10.7 1 12.6 7.6 311 3 309 165 2.9 0 3 2.8 12/16/2005 21:10:00 11 1.2 13.3 6.8 11 1.2 13.3 6.8 9.7 1.1 11.8 6.5 310 4 309 165 2.9 0 3 2.8 12/16/2005 21:20:00 10.5 0.9 12.6 7.6 10.4 1 12.6 7.2 9.1 1 11.1 6.5 310 5 303 165 2.8 0 2.8 2.8 12/16/2005 21:30:00 10.9 0.7 12.6 8.8 10.8 0.7 12.6 8.8 9.5 0.8 11.8 6.8 309 3 308 165 2.8 0 3 2.8 12/16/2005 21:40:00 11.1 0.8 13.3 8.8 11.1 0.8 13 8.8 9.6 1.1 11.8 6.5 309 3 309 165 2.7 0 2.8 2.6 12/16/2005 21:50:00 10.8 0.9 13.3 8.4 10.8 0.9 13 8 9.9 0.9 11.8 6.8 311 5 307 165 2.7 0 2.8 2.6 12/16/2005 22:00:00 10.9 0.9 13 8.8 10.9 0.9 12.6 8.4 9.6 1.1 12.2 6.5 310 4 307 165 2.6 0 2.8 2.6 12/16/2005 22:10:00 10.7 0.7 12.2 8.8 10.6 0.7 12.2 8.8 9.3 1.1 11.8 6.1 308 4 305 165 2.6 0 2.8 2.6 12/16/2005 22:20:00 11.3 0.7 13 9.1 11.2 0.7 13 9.1 10.6 1 12.6 8 312 4 312 165 2.7 0 2.8 2.6 12/16/2005 22:30:00 11 0.7 12.6 9.1 11 0.7 12.2 8.8 9.9 0.9 12.2 6.8 311 4 312 165 2.6 0 2.8 2.6 12/16/2005 22:40:00 10.7 0.7 12.6 8 10.6 0.7 12.2 8 9.5 1 11.5 6.8 310 5 307 165 2.6 0 2.8 2.6 12/16/2005 22:50:00 10.5 0.8 13 7.6 10.4 0.8 13 7.6 9 1 11.5 6.1 309 4 304 165 2.7 0 2.8 2.6 12/16/2005 23:00:00 9.8 1 13 7.2 9.7 1 13 6.8 7.5 1.1 10.7 5.3 304 6 310 165 2.8 0 2.8 2.8 12/16/2005 23:10:00 9.6 1.3 13.7 6.1 9.5 1.3 13 6.1 7.4 1.2 10.7 4.6 299 7 302 165 2.9 0 3.3 2.8 12/16/2005 23:20:00 8 1.6 11.5 3 8 1.5 11.1 3.4 6.2 1.5 9.9 2.6 301 11 298 165 3.1 0 3.5 3 12/16/2005 23:30:00 7.6 1.2 10.7 4.9 7.6 1.1 11.1 5.3 6.3 1.2 10.3 3.4 292 7 307 165 3.1 0 3.5 3 12/16/2005 23:40:00 6.8 1.3 10.3 3.4 6.9 1.2 10.3 3.4 6.3 1.3 9.9 2.6 286 8 292 165 3 0 3.3 3 12/16/2005 23:50:00 6.8 1 9.1 3.8 6.8 1 9.1 3.8 5.8 1.2 8.8 2.6 290 8 296 165 3 0 3.3 3 12/17/2005 00:00:00 6.3 1.5 9.1 1.5 6.3 1.4 9.1 1.5 5.5 1.4 8.8 1.9 295 12 296 165 3.1 0 3.3 3 12/17/2005 00:10:00 5.5 1.3 8 1.1 5.7 1.3 8 0.4 5 1.5 8.4 0.4 291 16 289 165 3.3 0 3.5 3.3 12/17/2005 00:20:00 6.5 1.4 10.3 3.4 6.5 1.4 9.9 3.4 5.4 1.3 9.9 2.6 299 11 293 165 3.3 0 3.5 3.3 12/17/2005 00:30:00 6.6 1 9.1 3.8 6.6 0.9 9.1 4.2 5.9 1.1 8.8 3 293 9 290 165 3.2 0 3.5 3.3 12/17/2005 00:40:00 6.3 1 8.8 3.4 6.3 1 9.1 3.8 5.3 1.1 10.3 1.9 296 10 291 165 3.3 0 3.5 3.3 12/17/2005 00:50:00 5.8 1.1 8.4 3 5.8 1 8.8 3 5 1 8 1.9 300 10 290 165 3.4 0 3.5 3.3 12/17/2005 01:00:00 6.2 1.3 8.8 3.8 6.1 1.3 8.8 3.4 5.2 1.2 8.4 2.6 299 9 288 165 3.3 0 3.5 3.3 12/17/2005 01:10:00 6.1 1 8.4 3.4 6.1 1.1 8.4 3.4 4.8 1.1 8 2.6 299 9 298 165 3.1 0.1 3.5 3 12/17/2005 01:20:00 5.8 1.1 8.8 3 5.8 1.1 8.4 3 4.7 0.9 6.8 2.3 299 10 300 165 3.1 0 3.3 3 12/17/2005 01:30:00 3.9 0.9 7.2 1.5 3.9 0.9 7.2 1.9 3.3 1 7.2 0.7 299 15 289 165 3.2 0 3.3 3 12/17/2005 01:40:00 1.5 1.1 4.2 0.4 1.7 1.1 4.2 0.4 1.4 1 3.4 0.4 251 47 307 165 3.1 0 3.3 3 12/17/2005 01:50:00 0.8 0.6 2.6 0.4 0.8 0.7 2.6 0.4 0.6 0.5 2.6 0.4 253 39 288 165 3.1 0 3.3 3 12/17/2005 02:00:00 2.4 0.7 4.2 0.7 2.4 0.7 4.2 0.7 1.9 0.7 3.8 0.4 286 11 283 165 3.2 0 3.3 3 12/17/2005 02:10:00 2.3 0.7 3.8 0.4 2.3 0.8 3.8 0.4 1.9 0.6 4.2 0.4 300 11 301 165 3.2 0 3.5 3 12/17/2005 02:20:00 1.9 0.5 3.4 0.7 1.9 0.5 3.4 0.7 1.4 0.4 2.6 0.4 298 11 300 165 3.2 0 3.3 3 12/17/2005 02:30:00 2.4 0.6 3.8 0.7 2.3 0.6 3.8 0.7 1.9 0.6 3.4 0.7 302 10 295 165 3.2 0 3.3 3 12/17/2005 02:40:00 3.1 0.5 4.2 1.5 3.1 0.5 4.2 1.5 2.3 0.5 3.4 1.1 301 7 305 165 3.1 0 3.3 3 12/17/2005 02:50:00 3.4 0.4 4.2 2.6 3.3 0.4 4.2 2.6 2.6 0.3 3.4 1.5 302 3 298 165 3.1 0 3.3 3 12/17/2005 03:00:00 3.1 0.3 3.8 2.3 3 0.4 3.8 2.3 2.5 0.4 3.4 1.5 307 4 310 165 3 0 3.3 3 12/17/2005 03:10:00 3.2 0.4 4.2 2.3 3.2 0.4 4.2 2.3 2.4 0.4 3.4 1.1 301 5 309 165 3 0 3 2.8 12/17/2005 03:20:00 3.1 0.4 3.8 1.9 3.2 0.3 3.8 2.3 2.4 0.4 3.4 1.1 305 3 304 165 3 0 3 2.8 12/17/2005 03:30:00 2.5 0.5 3.4 1.5 2.6 0.4 3.4 1.5 2 0.5 3 0.7 303 5 306 165 3 0 3.3 2.8 12/17/2005 03:40:00 2.7 0.6 4.6 1.5 2.8 0.6 4.6 1.9 2.1 0.5 3.4 1.1 302 7 302 165 2.9 0 3 2.8 12/17/2005 03:50:00 4.1 0.4 4.9 3 4.1 0.4 4.9 3 3.2 0.5 4.9 1.9 305 4 304 165 2.8 0 3 2.8 12/17/2005 04:00:00 4.1 0.4 4.9 2.6 4.1 0.3 4.9 3 3.1 0.4 4.2 1.9 294 6 295 165 2.8 0 3 2.8 12/17/2005 04:10:00 3.7 0.4 4.6 2.6 3.7 0.4 4.6 2.6 2.6 0.4 3.4 1.1 297 3 298 165 2.9 0 3 2.8 12/17/2005 04:20:00 3.5 0.5 4.2 1.9 3.6 0.4 4.6 2.3 2.7 0.5 3.8 1.5 291 5 295 165 2.9 0 3 2.8 12/17/2005 04:30:00 3.7 0.3 4.2 2.6 3.7 0.3 4.6 2.6 2.7 0.4 3.8 1.5 295 2 294 165 2.9 0 3 2.8 12/17/2005 04:40:00 3.4 0.4 4.2 1.9 3.4 0.4 4.2 1.9 2.9 0.4 3.8 1.9 289 6 294 165 2.9 0 3 2.8 12/17/2005 04:50:00 2.7 0.5 3.8 1.5 2.8 0.5 3.8 1.5 2.4 0.5 3.8 1.1 289 6 293 165 2.9 0 3 2.8 12/17/2005 05:00:00 2.7 0.4 3.8 1.5 2.7 0.4 3.8 1.9 2.1 0.4 3 1.1 295 5 300 165 2.8 0 2.8 2.8 12/17/2005 05:10:00 2.7 0.3 3.4 1.9 2.7 0.3 3.4 1.9 1.9 0.4 3 1.1 301 3 299 165 2.9 0 3 2.8 12/17/2005 05:20:00 2.2 0.3 3 1.5 2.2 0.4 3 1.5 1.9 0.3 2.6 1.1 312 8 305 165 2.9 0 3 2.8 12/17/2005 05:30:00 1.4 0.3 2.3 0.7 1.4 0.3 2.3 0.7 1.4 0.3 2.3 0.7 331 4 324 165 2.7 0 2.8 2.8 12/17/2005 05:40:00 1 0.3 1.9 0.4 0.8 0.4 1.9 0.4 0.7 0.3 1.5 0.4 348 12 336 165 2.7 0 2.8 2.8 12/17/2005 05:50:00 0.4 0.1 0.7 0.4 0.4 0.1 1.1 0.4 0.4 0.2 1.1 0.4 12 0 12 165 2.7 0 2.8 2.6 12/17/2005 06:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 12 0 165 165 2.9 0 3.3 2.8 12/17/2005 06:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 12 0 165 165 2.9 0 3.3 2.8 12/17/2005 06:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 12 0 165 165 2.7 0 2.8 2.8 12/17/2005 06:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0.2 1.1 0.4 12 0 165 165 2.7 0 2.8 2.6 12/17/2005 06:40:00 0.4 0.1 1.1 0.4 0.4 0 0.7 0.4 0.5 0.2 1.5 0.4 4 7 358 165 2.7 0 2.8 2.6 12/17/2005 06:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 358 0 165 165 2.8 0 3 2.6 12/17/2005 07:00:00 0.4 0 0.7 0.4 0.4 0.1 1.1 0.4 0.4 0 0.4 0.4 113 47 136 165 3 0 3 2.8 12/17/2005 07:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 139 0 165 165 3 0 3 2.8 12/17/2005 07:20:00 0.5 0.2 1.1 0.4 0.5 0.3 1.1 0.4 0.5 0.2 1.1 0.4 139 0 139 165 3 0 3.3 2.8 12/17/2005 07:30:00 0.7 0.4 1.5 0.4 1 0.3 1.5 0.4 1.1 0.3 1.9 0.4 147 5 150 165 2.8 0 3 2.8 12/17/2005 07:40:00 1.6 0.3 2.3 0.7 1.7 0.3 2.3 0.7 1.7 0.3 2.3 0.7 149 6 151 165 2.7 0 3 2.6 12/17/2005 07:50:00 1.1 0.3 1.5 0.4 1 0.4 1.5 0.4 0.9 0.3 1.5 0.4 147 1 145 165 2.6 0 2.8 2.6 12/17/2005 08:00:00 1.5 0.4 2.3 0.7 1.4 0.5 2.3 0.4 1.4 0.6 2.3 0.4 152 3 154 165 2.5 0 2.8 2.6 12/17/2005 08:10:00 1.5 0.4 1.9 0.4 1.4 0.5 1.9 0.4 1.6 0.6 2.3 0.4 148 4 155 165 2.6 0 2.8 2.6 12/17/2005 08:20:00 0.6 0.2 1.1 0.4 0.5 0.2 1.1 0.4 0.4 0.1 1.1 0.4 130 5 141 165 2.7 0 2.8 2.6 12/17/2005 08:30:00 1.3 0.4 2.3 0.7 1.3 0.4 2.3 0.4 1 0.5 1.9 0.4 133 6 147 165 2.8 0 2.8 2.6 12/17/2005 08:40:00 1.2 0.4 2.3 0.4 1.1 0.4 1.9 0.4 1 0.4 1.9 0.4 143 3 145 165 2.9 0 2.8 2.8 12/17/2005 08:50:00 1.7 0.3 2.3 0.7 1.5 0.3 2.3 0.7 1.4 0.5 2.3 0.4 150 4 148 165 2.7 0 3 2.8 12/17/2005 09:00:00 1.6 0.4 2.3 0.7 1.5 0.4 2.3 0.7 1.3 0.5 2.3 0.4 143 6 147 165 2.7 0 2.8 2.8 12/17/2005 09:10:00 2 0.5 3 0.7 2 0.5 3 0.7 2 0.4 2.6 0.7 139 5 145 165 2.8 0 2.8 2.8 12/17/2005 09:20:00 2.1 0.4 3 1.1 2.1 0.4 3 1.1 2.3 0.4 3.4 1.5 143 5 144 165 2.7 0 2.8 2.6 12/17/2005 09:30:00 2.6 0.3 3.4 1.9 2.5 0.3 3 1.9 2.7 0.2 3 2.3 147 4 151 165 2.6 0 2.8 2.6 12/17/2005 09:40:00 2.1 0.3 3 1.5 2.1 0.3 2.6 1.1 2.1 0.2 2.6 1.5 152 4 151 165 2.7 0 2.8 2.6 12/17/2005 09:50:00 2.4 0.2 3 1.9 2.3 0.2 2.6 1.9 2.4 0.2 3 1.9 157 2 160 165 2.9 0 3 2.8 12/17/2005 10:00:00 2.6 0.2 3 1.9 2.5 0.2 3 1.9 2.7 0.2 3 1.9 158 2 156 165 2.9 0 3 2.8 12/17/2005 10:10:00 2.2 0.3 3 1.5 2.1 0.3 3 1.5 2.3 0.3 3 1.5 154 6 153 165 2.9 0 3 2.8 12/17/2005 10:20:00 2.1 0.4 3 1.1 1.9 0.4 2.6 1.1 2.3 0.3 3 1.5 155 5 160 165 3 0 3 2.8 12/17/2005 10:30:00 1.8 0.4 2.6 0.7 1.7 0.4 2.3 0.7 2.1 0.3 2.6 1.1 151 5 159 165 3 0 3.3 2.8 12/17/2005 10:40:00 0.7 0.4 1.5 0.4 0.6 0.3 1.5 0.4 0.7 0.4 1.9 0.4 141 5 150 165 3.1 0 3.3 3 12/17/2005 10:50:00 1.4 0.7 2.6 0.4 1.4 0.7 2.6 0.4 1.5 0.8 3 0.4 143 1 145 165 3.2 0 3.3 3 12/17/2005 11:00:00 3.3 0.4 4.2 2.3 3.2 0.4 4.2 2.3 3.4 0.4 4.2 2.6 151 3 151 165 3 0 3.3 2.8 12/17/2005 11:10:00 2.9 0.4 3.8 1.9 2.8 0.4 3.4 1.9 2.8 0.4 3.8 2.3 156 3 155 165 2.9 0 3 2.8 12/17/2005 11:20:00 2.7 0.3 3.4 1.9 2.7 0.3 3.4 1.9 2.6 0.3 3.4 1.9 144 4 138 165 2.9 0 3 2.8 12/17/2005 11:30:00 2.6 0.4 3.4 1.9 2.6 0.4 3.8 1.9 2.4 0.4 3 1.5 132 6 140 165 3 0 3.3 2.8 12/17/2005 11:40:00 3.5 0.5 4.6 1.9 3.6 0.5 4.6 1.9 3.3 0.5 4.6 2.3 130 6 125 165 3.1 0 3.3 3 12/17/2005 11:50:00 2.8 0.6 4.2 1.5 2.9 0.7 4.6 1.5 2.8 0.7 4.6 0.7 125 10 122 165 3.1 0 3.3 3 12/17/2005 12:00:00 3.7 0.5 5.3 2.6 3.8 0.6 5.7 2.6 3.5 0.5 4.9 2.3 122 7 106 165 3 0 3.3 3 12/17/2005 12:10:00 4.4 0.6 5.7 2.6 4.4 0.6 6.1 2.3 4.2 0.6 6.1 3 123 10 106 165 3.1 0 3.3 3 12/17/2005 12:20:00 5.3 0.5 6.1 4.2 5.4 0.5 6.5 4.2 5 0.5 6.1 3.8 118 3 117 165 3.2 0 3.3 3 12/17/2005 12:30:00 5.5 0.5 6.8 3.8 5.6 0.5 7.2 3.8 5.3 0.5 6.8 3.8 119 4 125 165 3 0 3.3 2.8 12/17/2005 12:40:00 5.1 0.5 6.1 3.8 5.1 0.5 6.5 3.8 5.1 0.5 6.5 3.8 149 12 165 165 3 0 3 2.8 12/17/2005 12:50:00 4.6 0.4 5.7 3.4 4.6 0.4 5.7 3 4.4 0.4 5.3 3.4 141 4 143 165 2.9 0 3 2.8 12/17/2005 13:00:00 4.8 0.7 6.5 3.4 5 0.8 6.5 3.4 4.8 0.7 6.5 3 129 3 128 165 3.1 0 3.3 3 12/17/2005 13:10:00 5.6 0.7 7.2 3.8 5.7 0.8 7.2 3.8 5.5 0.7 7.2 3.8 125 7 139 165 3.3 0 3.5 3.3 12/17/2005 13:20:00 5.4 0.6 7.2 4.2 5.5 0.6 7.2 4.2 5.3 0.6 7.2 3.8 124 5 122 165 3.2 0 3.5 3.3 12/17/2005 13:30:00 6.9 0.7 8.4 4.6 6.9 0.6 8.4 4.6 6.9 0.7 8.4 4.2 136 8 139 165 3.3 0 3.5 3.3 12/17/2005 13:40:00 6.7 0.7 8.4 4.9 6.7 0.7 8 5.3 6.6 0.6 8.4 5.3 142 9 145 165 3.5 0 3.8 3.3 12/17/2005 13:50:00 6.3 0.6 7.2 4.9 6.2 0.6 7.6 4.6 6.4 0.6 8 4.2 156 4 154 165 3.3 0 3.5 3.3 12/17/2005 14:00:00 5.9 0.3 6.5 5.3 5.8 0.3 6.5 4.9 5.9 0.3 6.8 4.9 151 3 155 165 3.4 0 3.5 3.3 12/17/2005 14:10:00 5.1 0.4 5.7 4.2 5 0.4 5.7 3.8 5 0.5 6.1 3.4 152 4 150 165 3.5 0 3.5 3.3 12/17/2005 14:20:00 4.9 0.5 5.7 3.4 4.9 0.5 5.7 3.4 4.9 0.4 6.1 3.4 149 6 151 165 4 0.2 4.3 3.5 12/17/2005 14:30:00 4.6 0.4 5.3 3.4 4.5 0.4 5.3 3.4 4.5 0.4 5.7 3.4 150 5 151 165 4 0 4.3 3.8 12/17/2005 14:40:00 4 0.5 4.9 3 3.9 0.5 4.9 3 3.9 0.5 5.3 2.6 148 5 143 165 3.7 0.1 3.8 3.5 12/17/2005 14:50:00 3.8 0.6 5.3 1.9 3.7 0.6 4.9 1.9 3.6 0.7 4.9 1.9 142 8 145 165 3.4 0 3.5 3.3 12/17/2005 15:00:00 5.4 0.5 6.8 3.8 5.4 0.5 6.8 3.8 5.3 0.6 6.8 3.8 138 6 141 165 3.3 0 3.5 3.3 12/17/2005 15:10:00 6.3 0.7 7.6 4.9 6.3 0.7 8 4.6 6.2 0.7 7.6 4.6 137 6 129 165 3.4 0 3.5 3.3 12/17/2005 15:20:00 8.6 2.1 11.8 5.3 8.6 2.1 12.6 5.3 8.5 2.1 11.8 5.3 143 6 141 165 3.2 0.1 3.5 3 12/17/2005 15:30:00 8.3 1.3 11.1 4.9 8.3 1.3 11.1 5.3 8.3 1.3 11.1 5.7 147 4 150 165 2.9 0 3.3 2.8 12/17/2005 15:40:00 4 0.6 6.1 3 4 0.6 6.1 3 3.9 0.7 6.1 2.3 138 5 146 165 2.7 0 2.8 2.6 12/17/2005 15:50:00 3.9 0.3 4.6 3 4 0.3 4.6 3 3.8 0.3 4.6 3 129 5 126 165 2.5 0.1 2.8 2.6 12/17/2005 16:00:00 4 0.3 4.9 3 4 0.3 4.6 3 4 0.3 4.6 3 135 4 136 165 2.4 0 2.6 2.3 12/17/2005 16:10:00 4.4 0.4 5.3 3 4.4 0.4 5.3 3 4.2 0.4 4.9 2.6 127 7 127 165 2.4 0 2.6 2.3 12/17/2005 16:20:00 5 0.6 6.5 3.8 5 0.7 6.5 3.8 4.9 0.6 6.1 3.4 113 5 114 165 2.5 0 2.8 2.6 12/17/2005 16:30:00 6.7 0.4 8 5.7 6.9 0.5 8.4 5.7 6.4 0.6 7.6 4.6 117 3 119 165 2.7 0 2.8 2.6 12/17/2005 16:40:00 7 0.3 7.6 6.1 7.2 0.3 8 6.5 6.9 0.4 7.6 5.3 122 2 111 165 2.8 0 2.8 2.8 12/17/2005 16:50:00 7 0.3 8 6.1 7.2 0.3 8 6.5 6.8 0.5 8 4.9 119 4 117 165 2.9 0 3 2.8 12/17/2005 17:00:00 7.6 0.5 9.1 5.7 7.8 0.5 8.8 6.1 7.4 0.6 8.8 4.9 118 4 123 165 2.9 0 3 2.8 12/17/2005 17:10:00 6.5 0.6 8 5.3 6.7 0.6 8 5.3 6.4 0.6 8 4.6 119 5 129 165 2.9 0 3 2.8 12/17/2005 17:20:00 7.6 0.4 8.8 6.5 7.8 0.4 8.8 6.5 7 0.7 8.4 4.9 113 3 116 165 2.9 0 3 2.8 12/17/2005 17:30:00 7.6 0.4 8.8 6.5 7.9 0.4 8.8 6.5 7.3 0.6 8.8 5.3 115 3 113 165 2.8 0 3 2.8 12/17/2005 17:40:00 7.4 0.4 8.4 6.5 7.5 0.4 8.8 6.1 7.1 0.5 8 4.6 116 3 120 165 2.7 0 2.8 2.6 12/17/2005 17:50:00 8 0.5 9.5 6.1 8.2 0.5 9.5 6.8 7.6 0.7 9.1 5.7 114 3 116 165 2.7 0 2.8 2.6 12/17/2005 18:00:00 8.8 0.4 9.5 6.8 9.1 0.4 9.9 7.2 8.3 0.7 9.5 6.1 114 3 114 165 2.9 0 3 2.6 12/17/2005 18:10:00 9 0.4 10.3 6.5 9.3 0.5 10.7 6.1 8.5 0.7 9.9 6.5 116 3 123 165 3 0 3.3 2.8 12/17/2005 18:20:00 9.3 0.8 11.1 7.6 9.5 0.7 11.5 8 9.2 0.8 11.8 6.8 125 5 124 165 3 0 3.3 2.8 12/17/2005 18:30:00 9.9 0.7 12.2 8.4 10.2 0.7 11.8 8.4 10 0.7 11.8 7.6 128 5 126 165 3 0 3 2.8 12/17/2005 18:40:00 9.7 0.6 11.8 7.6 9.9 0.6 11.8 7.6 9.6 0.7 11.5 7.6 126 5 125 165 2.9 0 3 2.8 12/17/2005 18:50:00 9.2 0.8 11.5 7.2 9.4 0.8 11.8 7.2 9.1 0.8 11.8 7.2 125 4 128 165 2.9 0 3 2.8 12/17/2005 19:00:00 10.2 1 12.6 8.4 10.4 1 13 8.4 9.9 1.1 12.6 7.6 124 4 118 165 3 0 3 2.8 12/17/2005 19:10:00 11.1 0.8 13.7 9.1 11.3 0.8 14.1 9.5 11 0.8 13 8.4 126 5 123 165 3 0 3 2.8 12/17/2005 19:20:00 11.2 0.8 13 8.8 11.4 0.8 13.3 8.8 11 0.8 13.3 8.4 125 5 131 165 3 0 3 2.8 12/17/2005 19:30:00 10.4 1 13.3 8.4 10.6 1 14.1 8.4 10.1 1.1 13.7 6.5 119 7 125 165 3 0 3.3 2.8 12/17/2005 19:40:00 10.8 0.8 13.7 8.4 11 0.8 14.1 9.1 10.5 1 14.5 6.8 123 6 118 165 2.9 0 3 2.8 12/17/2005 19:50:00 14.1 2.3 19.1 9.9 14.2 2.3 19.1 9.9 14 2.4 19.9 9.5 142 9 151 165 2.7 0.2 3 2.3 12/17/2005 20:00:00 12 2.5 18.3 7.6 12.1 2.4 18.3 7.6 11.8 2.5 17.9 7.6 141 7 147 165 2.3 0 2.6 2.1 12/17/2005 20:10:00 9.2 1.4 12.6 5.3 9.3 1.4 12.6 5.7 9.1 1.5 11.8 5.7 128 9 135 165 2.5 0.1 2.8 2.3 12/17/2005 20:20:00 8.4 1 10.7 6.1 8.6 1 11.1 6.1 7.9 1 10.3 4.9 115 4 117 165 2.9 0 3 2.8 12/17/2005 20:30:00 9.6 0.7 11.5 6.8 9.8 0.7 11.5 7.2 9.2 0.9 11.5 6.5 118 3 115 165 3 0 3.3 2.8 12/17/2005 20:40:00 10 0.8 12.2 8.4 10.2 0.8 12.2 8.8 9.6 0.8 11.8 7.2 122 4 119 165 3.1 0 3.3 3 12/17/2005 20:50:00 10.3 0.8 12.6 8.4 10.5 0.8 13 8.8 10 0.8 12.6 7.6 123 5 121 165 3.2 0 3.3 3 12/17/2005 21:00:00 9 0.7 10.7 7.2 9.1 0.6 10.7 7.6 9 0.7 11.1 6.8 130 5 126 165 3.3 0 3.3 3.3 12/17/2005 21:10:00 9.1 1 11.8 7.2 9.2 1 12.2 7.6 8.9 1 12.2 6.5 125 5 116 165 3.3 0 3.5 3.3 12/17/2005 21:20:00 11.3 1.5 14.5 7.6 11.5 1.5 14.9 8 10.9 1.5 15.6 7.2 122 8 115 165 3.2 0 3.5 3 12/17/2005 21:30:00 9.8 1.1 12.6 7.6 10 1.1 13 7.2 9.2 1.2 12.6 6.1 118 8 114 165 2.8 0 3 2.6 12/17/2005 21:40:00 7.7 1.3 11.1 4.2 7.8 1.3 11.1 4.2 7.3 1.4 11.1 3.8 128 9 131 165 2.6 0.1 2.8 2.6 12/17/2005 21:50:00 11.4 1.6 14.9 7.6 11.5 1.7 14.9 8 11.3 1.8 14.9 7.6 141 5 138 165 2.3 0 2.6 2.3 12/17/2005 22:00:00 9.4 1.5 13.3 6.1 9.4 1.5 13.3 5.7 9.2 1.5 12.6 5.7 135 10 120 165 2.1 0 2.3 2.1 12/17/2005 22:10:00 10.1 1 13.3 7.6 10.2 1 13.3 7.2 9.7 0.9 12.6 7.2 121 6 118 165 2.3 0.1 2.6 2.1 12/17/2005 22:20:00 9.2 1 11.5 6.8 9.4 1 11.5 6.8 8.5 1 11.1 5.3 116 6 115 165 2.6 0 2.8 2.6 12/17/2005 22:30:00 9.8 0.6 11.5 7.6 10 0.6 11.5 8 9.1 0.8 10.7 6.1 110 4 115 165 3 0 3.3 2.8 12/17/2005 22:40:00 10.5 0.6 12.2 8.8 10.8 0.6 12.6 9.1 9.9 0.8 11.8 7.2 108 3 110 165 3.3 0 3.5 3 12/17/2005 22:50:00 11.3 0.7 13.3 8.4 11.6 0.7 13.3 8.8 10.8 0.9 13.3 7.6 108 4 114 165 3.5 0 3.5 3.5 12/17/2005 23:00:00 11.3 0.8 13.7 8.4 11.6 0.8 13.7 9.1 10.8 0.9 13 8 108 4 107 165 3.6 0 3.8 3.5 12/17/2005 23:10:00 11.3 1 13.3 8.4 11.5 1 14.1 8.8 10.6 1.1 13 6.5 110 5 113 165 3.6 0 3.8 3.5 12/17/2005 23:20:00 10.9 0.9 13 7.6 11.2 1 13 8 10.1 1.1 12.2 6.8 111 4 112 165 3.6 0 3.8 3.5 12/17/2005 23:30:00 10.8 1 13.7 7.2 11 1.1 13.7 7.2 10 1.2 13 6.5 110 5 111 165 3.7 0 3.8 3.5 12/17/2005 23:40:00 10.7 0.8 13.3 8.8 10.9 0.8 13.3 8.4 10 1 12.2 7.2 108 5 102 165 3.7 0 3.8 3.5 12/17/2005 23:50:00 11.2 2.3 15.3 6.5 11.4 2.3 15.6 6.1 10.5 2.5 15.3 6.1 118 8 122 165 3.3 0.3 3.8 2.8 12/18/2005 00:00:00 12.4 1.3 15.3 8.8 12.6 1.3 15.6 9.1 11.5 1.5 14.9 7.6 115 6 113 165 2.6 0 2.8 2.6 12/18/2005 00:10:00 13 1 15.6 10.7 13.2 1 16.1 11.1 12.3 1.2 15.3 9.1 106 4 102 165 3 0 3.3 2.8 12/18/2005 00:20:00 12 0.8 14.1 9.1 12.3 0.9 14.1 9.5 11.2 1.2 13.3 7.6 106 5 107 165 3.2 0 3.5 3 12/18/2005 00:30:00 11.4 1.3 14.1 9.1 11.6 1.3 14.5 9.1 10.8 1.3 14.1 7.6 113 5 105 165 3 0.1 3.5 2.8 12/18/2005 00:40:00 10.5 0.6 12.2 8 10.8 0.6 12.2 8.4 9.8 0.8 11.8 7.6 107 3 111 165 3 0 3.3 2.8 12/18/2005 00:50:00 11.4 0.6 13 9.5 11.7 0.6 13 9.9 10.6 1 12.6 7.6 109 3 110 165 3.3 0 3.5 3 12/18/2005 01:00:00 11.1 0.6 13 8.8 11.3 0.6 13 8.8 10.3 0.8 12.2 7.6 108 3 114 165 3.5 0 3.5 3.3 12/18/2005 01:10:00 11.6 0.8 13.7 8.8 11.8 0.8 14.1 8.8 10.9 1.1 13.3 6.8 106 5 102 165 3.6 0 3.8 3.5 12/18/2005 01:20:00 11.5 1 13.7 8.4 11.8 1 14.9 8.8 11 1.1 13.3 8 109 5 98 165 3.8 0 3.8 3.5 12/18/2005 01:30:00 11.1 1 14.1 8.4 11.3 1 14.1 8.4 10.4 1.2 13.3 7.6 114 5 110 165 3.6 0 3.8 3.5 12/18/2005 01:40:00 11.2 0.9 13.3 8.4 11.5 0.9 13.7 8.8 10.6 1.2 13.3 6.8 113 6 114 165 3.6 0 3.8 3.5 12/18/2005 01:50:00 11.1 0.8 12.6 8.4 11.3 0.8 13 8.4 10.5 1 13 7.6 110 4 97 165 3.6 0 3.8 3.5 12/18/2005 02:00:00 10.6 0.9 13 8.4 10.8 0.9 13.7 8.4 9.8 1.1 13 6.8 110 4 108 165 3.6 0 3.5 3.5 12/18/2005 02:10:00 10.2 0.7 13 8.4 10.4 0.7 13 8.4 9.6 0.9 11.8 7.2 108 5 106 165 3.6 0 3.8 3.5 12/18/2005 02:20:00 10.6 0.9 13 7.6 10.8 0.9 13 7.6 10.1 1 13 6.8 108 5 111 165 3.6 0 3.8 3.5 12/18/2005 02:30:00 11 0.8 13 7.6 11.2 0.8 13.3 7.2 10.3 1 12.6 7.6 113 5 111 165 3.7 0 3.8 3.5 12/18/2005 02:40:00 10.6 0.8 13 7.6 10.8 0.8 13 7.6 10.1 1 12.2 7.2 116 5 105 165 3.8 0 3.8 3.8 12/18/2005 02:50:00 10.6 0.8 13 8.8 10.8 0.8 13.7 9.1 10.2 0.8 12.6 7.6 118 5 111 165 3.8 0 4 3.8 12/18/2005 03:00:00 10.6 1 13.3 8 10.8 1 13.7 8.4 10 1 12.6 7.2 116 6 116 165 3.8 0 4 3.8 12/18/2005 03:10:00 11.2 1 13.7 8 11.4 1 14.1 8.4 10.5 1.1 13.3 7.2 108 5 105 165 3.9 0 4 3.8 12/18/2005 03:20:00 11.2 1 14.1 7.6 11.4 1 14.5 8 10.5 1.2 13.3 7.2 109 5 109 165 4 0 4.3 3.8 12/18/2005 03:30:00 10.8 1.1 13.3 8 11 1.1 13.3 8.4 10.2 1.2 13 6.8 107 5 107 165 4 0 4.3 4 12/18/2005 03:40:00 10.9 1.1 13.7 8.4 11.2 1.1 14.1 8.4 10.4 1.2 13.3 7.2 114 7 111 165 4.1 0 4.3 4 12/18/2005 03:50:00 10.3 1.4 14.1 7.2 10.6 1.4 14.5 7.2 9.9 1.5 14.5 6.5 120 7 121 165 4.1 0 4.3 4 12/18/2005 04:00:00 11.3 1 14.1 8.4 11.6 1 14.5 7.6 10.9 1.1 13 7.6 119 6 118 165 4.1 0 4.3 4 12/18/2005 04:10:00 12.1 1.4 15.6 8 12.4 1.5 16.1 8 11.4 1.6 15.3 7.6 111 6 112 165 4.1 0 4.3 4.3 12/18/2005 04:20:00 12.5 1.1 15.3 9.1 12.7 1.2 15.6 9.1 11.7 1.5 14.5 7.6 109 5 112 165 4.2 0 4.5 4.3 12/18/2005 04:30:00 12.7 1.2 15.6 8.4 12.9 1.2 15.6 8.4 11.8 1.3 15.6 8 108 6 102 165 4.3 0 4.5 4.3 12/18/2005 04:40:00 13.1 1.5 16.4 8.8 13.3 1.5 17.2 8.8 12.2 1.7 15.6 8 113 5 111 165 4.3 0 4.5 4.3 12/18/2005 04:50:00 14.2 1.2 16.8 10.7 14.4 1.2 17.2 11.1 13.3 1.5 16.4 8.4 109 6 109 165 4.4 0 4.5 4.3 12/18/2005 05:00:00 14.2 1.5 17.2 10.7 14.5 1.5 17.6 10.3 13.3 1.5 16.8 9.9 110 6 107 165 4.4 0 4.5 4.3 12/18/2005 05:10:00 14.4 1.5 17.6 9.9 14.7 1.6 17.9 9.9 13.4 1.8 17.9 8.4 113 5 102 165 4.4 0 4.5 4.3 12/18/2005 05:20:00 14.2 1.7 18.7 9.9 14.4 1.7 19.1 10.3 13.5 1.9 19.1 8.4 118 6 119 165 4.4 0 4.5 4.3 12/18/2005 05:30:00 14.2 1.5 18.7 8.8 14.4 1.5 18.7 9.1 13.5 1.6 17.2 8.4 120 6 138 165 4.4 0 4.5 4.3 12/18/2005 05:40:00 14.3 1.6 17.9 9.1 14.5 1.6 17.9 9.5 13.8 1.6 17.9 8.8 121 6 118 165 4.3 0 4.5 4.3 12/18/2005 05:50:00 14.1 1.5 17.6 8 14.3 1.5 18.3 8 13.6 1.7 18.3 8.4 120 6 125 165 4.3 0 4.5 4.3 12/18/2005 06:00:00 13.7 1.5 17.2 9.1 13.9 1.5 17.2 9.9 13.2 1.7 17.6 9.5 121 6 121 165 4.4 0 4.5 4.3 12/18/2005 06:10:00 13.5 1.7 17.9 8 13.6 1.7 18.3 7.6 12.9 1.8 17.6 7.6 117 7 110 165 4.4 0 4.5 4.3 12/18/2005 06:20:00 14.1 1.8 18.7 9.9 14.3 1.8 18.7 10.3 13.4 1.9 18.7 9.1 112 8 119 165 4.5 0 4.8 4.5 12/18/2005 06:30:00 13.7 1.6 17.6 8.8 13.9 1.6 17.9 9.1 12.8 1.7 17.6 7.6 113 7 107 165 4.4 0 4.5 4.3 12/18/2005 06:40:00 14.1 1.8 19.1 9.5 14.3 1.8 19.1 9.9 13.5 2.1 19.9 8.4 116 6 112 165 4.4 0 4.5 4.3 12/18/2005 06:50:00 13.3 1.7 16.8 8.4 13.5 1.7 17.6 8.4 12.6 1.7 17.2 8.8 116 8 111 165 4.4 0 4.5 4.3 12/18/2005 07:00:00 13.9 2.2 19.1 7.2 14.1 2.2 19.1 7.6 13.2 2.1 17.2 6.8 112 7 107 165 4.5 0 4.8 4.3 12/18/2005 07:10:00 14.3 1.5 18.3 9.9 14.5 1.5 17.9 8.8 13.8 1.6 17.9 8 116 8 116 165 4.6 0 4.8 4.5 12/18/2005 07:20:00 14.7 1.8 19.1 10.3 14.9 1.8 19.5 10.3 14.2 1.8 18.3 9.9 119 7 111 165 4.7 0 4.8 4.5 12/18/2005 07:30:00 14.2 1.6 17.9 9.9 14.3 1.6 18.3 9.9 13.6 1.7 17.9 9.9 122 8 121 165 4.8 0 5 4.8 12/18/2005 07:40:00 14.1 2 19.5 9.5 14.3 2 19.9 9.1 13.9 1.9 19.1 9.5 124 9 111 165 4.9 0 5 4.8 12/18/2005 07:50:00 15.3 1.5 19.9 9.9 15.3 1.5 19.9 10.7 15.1 1.7 21 9.9 131 10 129 165 4.9 0 5 5 12/18/2005 08:00:00 17.6 1.8 22.1 13 17.6 1.8 21.8 13 17.5 2.1 22.1 11.8 142 7 144 165 4.8 0.2 5 4.5 12/18/2005 08:10:00 15.3 0.8 17.6 13.3 15.3 0.8 17.6 13.3 15.3 0.9 17.2 13.3 151 4 150 165 4.4 0 4.5 4.5 12/18/2005 08:20:00 16.5 1.5 19.1 13 16.5 1.4 19.1 13.3 16.4 1.5 19.5 12.6 151 3 150 165 4.3 0.1 4.5 4.3 12/18/2005 08:30:00 15.2 0.9 17.2 13 15.2 0.9 17.2 12.6 15 1.1 17.2 12.2 146 5 148 165 4.2 0 4.5 4.3 12/18/2005 08:40:00 15.3 0.9 17.6 12.2 15.4 1 17.6 12.2 15 1.2 17.9 10.3 143 4 145 165 4.3 0 4.5 4.3 12/18/2005 08:50:00 13.5 0.9 15.3 10.3 13.6 1 15.3 10.3 13.1 1.1 15.3 10.3 142 4 146 165 4.3 0 4.5 4.3 12/18/2005 09:00:00 12.6 1 14.9 9.9 12.8 1 14.9 10.3 12.4 1.1 14.9 9.9 141 4 143 165 4.1 0 4.5 4.3 12/18/2005 09:10:00 12.2 0.9 14.1 9.9 12.2 0.9 14.5 10.3 11.9 1 14.1 9.1 141 4 141 165 4.1 0 4.3 4.3 12/18/2005 09:20:00 11.8 0.7 13.7 9.9 11.9 0.7 14.1 9.9 11.4 1 13.3 9.1 141 4 143 165 4.2 0 4.3 4.3 12/18/2005 09:30:00 11.7 0.8 13.3 9.5 11.7 0.8 13.7 9.5 11.4 0.9 13.3 8 145 4 145 165 4.1 0 4.3 4.3 12/18/2005 09:40:00 10.4 0.7 11.8 8.8 10.5 0.7 12.2 8.8 10.2 0.7 12.2 8 144 4 139 165 4.1 0 4.3 4.3 12/18/2005 09:50:00 10.5 0.7 11.8 8.4 10.5 0.6 11.8 8 10.3 0.8 11.8 8 144 3 148 165 4.1 0 4.3 4.3 12/18/2005 10:00:00 10.3 0.5 11.5 8.8 10.2 0.4 11.5 8.8 10.3 0.6 11.5 8 148 4 145 165 4.1 0 4.3 4.3 12/18/2005 10:10:00 10.4 0.4 11.5 8.8 10.2 0.4 11.1 8.8 10.7 0.4 11.8 9.1 154 4 160 165 4.1 0 4.3 4.3 12/18/2005 10:20:00 10 0.5 11.5 8.8 9.8 0.4 11.5 8.4 10.2 0.4 11.8 9.1 156 4 162 165 4.2 0 4.3 4.3 12/18/2005 10:30:00 10.1 0.5 11.5 7.6 9.9 0.5 11.1 7.6 10.3 0.6 11.8 8 156 3 163 165 4.2 0 4.5 4.3 12/18/2005 10:40:00 9.2 0.4 9.9 8 9.1 0.4 9.9 7.6 9.4 0.3 10.3 8.4 155 3 156 165 4.2 0 4.3 4.3 12/18/2005 10:50:00 8.9 0.3 9.5 7.6 9 0.3 9.5 7.6 8.9 0.5 9.9 7.2 148 4 156 165 4.1 0 4.3 4.3 12/18/2005 11:00:00 7.9 0.5 9.1 6.8 8 0.5 9.1 6.5 7.8 0.5 8.8 6.1 145 3 143 165 4.1 0 4.3 4.3 12/18/2005 11:10:00 7.9 0.5 9.1 6.8 7.9 0.5 9.1 6.5 8 0.5 9.1 6.5 145 3 145 165 4.1 0 4.3 4.3 12/18/2005 11:20:00 8.7 1 10.7 6.8 8.8 1.1 11.1 6.8 8.6 1 11.1 6.8 145 5 139 165 4.1 0 4.3 4.3 12/18/2005 11:30:00 10 0.8 11.8 8 10.1 0.8 11.8 8.4 10.1 0.8 11.8 7.6 143 4 139 165 4.1 0 4.3 4 12/18/2005 11:40:00 11.2 0.7 12.6 9.1 11.1 0.7 13 8.4 11.1 0.8 12.6 8.8 141 3 142 165 4 0 4.3 4 12/18/2005 11:50:00 11.2 0.5 13 9.5 11.2 0.5 12.6 9.9 11.3 0.6 13 9.5 140 4 133 165 4 0 4.3 3.8 12/18/2005 12:00:00 10.4 1 12.2 8 10.4 0.9 12.2 8 10.3 0.9 12.6 8.4 141 4 140 165 3.9 0 4 3.8 12/18/2005 12:10:00 8.5 0.6 9.5 6.5 8.5 0.6 9.9 6.5 8.5 0.6 9.9 6.8 140 5 144 165 3.8 0 4 3.8 12/18/2005 12:20:00 7.9 0.7 9.5 5.7 7.9 0.7 9.9 6.1 7.7 0.7 9.5 5.3 135 6 133 165 3.8 0 4 3.8 12/18/2005 12:30:00 8.1 0.6 9.5 5.7 8.1 0.5 9.5 5.7 8 0.5 9.1 6.1 138 4 137 165 4 0 4 3.8 12/18/2005 12:40:00 7.2 0.6 8.8 4.9 7.2 0.6 8.4 5.3 7.2 0.6 8.4 4.9 130 5 135 165 3.9 0 4 3.8 12/18/2005 12:50:00 6.2 0.5 7.2 4.6 6.2 0.5 7.2 4.9 6.1 0.6 7.2 4.6 135 6 133 165 4 0 4.3 3.8 12/18/2005 13:00:00 6.3 0.8 8 4.2 6.4 0.8 8 4.2 6.2 0.9 8.4 3.8 133 7 135 165 4 0 4 3.8 12/18/2005 13:10:00 5.9 0.5 7.2 4.2 6 0.6 7.6 4.6 5.8 0.6 7.6 4.2 126 7 116 165 4 0 4.3 3.8 12/18/2005 13:20:00 6.3 0.6 7.6 4.9 6.4 0.6 8 4.9 6 0.8 7.6 3.4 112 6 106 165 4 0 4.3 3.8 12/18/2005 13:30:00 6.8 0.8 9.1 4.6 7 0.8 9.5 4.6 6.5 0.9 8.4 4.2 106 4 106 165 4.1 0 4.3 4 12/18/2005 13:40:00 8.4 0.8 11.1 6.5 8.6 0.8 11.1 6.8 8 0.9 11.1 5.7 109 5 110 165 4.2 0 4.3 4.3 12/18/2005 13:50:00 8.9 0.7 10.7 7.6 9 0.7 11.1 7.6 8.5 0.8 10.7 6.8 111 5 105 165 4.2 0 4.5 4.3 12/18/2005 14:00:00 7.5 0.6 8.8 5.3 7.6 0.6 9.1 5.7 7.2 0.6 8.8 4.9 114 5 116 165 4.2 0 4.3 4.3 12/18/2005 14:10:00 7.6 0.9 9.9 5.7 7.8 0.9 9.9 6.1 7.3 1 9.5 4.9 111 9 119 165 4.3 0 4.5 4.3 12/18/2005 14:20:00 6.2 0.4 7.2 4.9 6.4 0.4 7.2 4.9 5.7 0.6 6.8 3.8 96 4 100 165 4.5 0 4.8 4.5 12/18/2005 14:30:00 5.9 0.7 7.2 3 6.1 0.7 7.2 3 5.7 0.7 7.2 3 88 11 96 165 4.6 0 4.8 4.5 12/18/2005 14:40:00 3.2 0.6 5.3 1.5 3.2 0.7 5.7 1.5 3.1 0.5 4.9 1.9 56 12 72 165 4.4 0 4.8 4.3 12/18/2005 14:50:00 4.3 0.7 6.5 2.6 4.4 0.8 6.5 2.6 3.9 0.6 5.7 2.3 59 15 68 165 4.4 0 4.5 4.3 12/18/2005 15:00:00 4.1 0.4 4.9 3 4 0.4 5.3 3 4.2 0.4 5.3 3 30 4 37 165 4.3 0 4.5 4.3 12/18/2005 15:10:00 4 0.4 4.9 3 4 0.4 4.9 3 3.9 0.4 4.9 2.6 43 6 43 165 4.4 0 4.5 4.3 12/18/2005 15:20:00 3.7 0.4 4.6 2.3 3.7 0.4 4.6 2.3 3.6 0.4 4.6 2.3 41 5 46 165 4.4 0 4.5 4.3 12/18/2005 15:30:00 4.4 0.6 5.7 2.6 4.4 0.6 6.1 2.6 4.1 0.6 5.7 2.3 42 6 46 165 4.4 0 4.5 4.3 12/18/2005 15:40:00 4.8 0.8 7.2 2.6 4.8 0.9 7.2 2.6 4.5 0.8 6.8 2.6 49 8 52 165 4.6 0 4.8 4.5 12/18/2005 15:50:00 5.8 0.9 8.4 3.4 5.9 0.9 8.4 3.4 5.4 0.9 8.4 3.4 58 9 74 165 4.9 0 5 4.8 12/18/2005 16:00:00 6.4 1 8.8 3.8 6.5 1 8.8 3.8 6.1 1 8.8 3.8 66 8 63 165 5.1 0 5.2 5 12/18/2005 16:10:00 7.2 1.2 10.3 4.6 7.3 1.2 10.3 4.2 6.8 1.2 11.1 4.6 70 9 82 165 5.2 0 5.5 5 12/18/2005 16:20:00 7.2 0.9 9.5 4.9 7.3 1 9.5 4.9 6.9 0.9 9.5 4.6 68 7 75 165 5.2 0 5.5 5.2 12/18/2005 16:30:00 7.9 1.5 11.5 4.2 8.1 1.5 11.5 4.2 7.7 1.3 11.1 4.6 72 9 69 165 5.2 0 5.5 5.2 12/18/2005 16:40:00 10.4 1 12.2 7.6 10.6 1 13 7.6 9.8 1 12.2 6.5 82 7 81 165 5.2 0 5.5 5.2 12/18/2005 16:50:00 10 1.4 12.6 6.8 10.2 1.5 13 6.5 9.4 1.4 12.6 6.1 81 6 79 165 5.2 0 5.5 5.2 12/18/2005 17:00:00 11.1 1.2 13.7 7.2 11.3 1.3 14.1 7.2 10.5 1.3 13 6.8 85 6 86 165 5.2 0 5.5 5.2 12/18/2005 17:10:00 11.4 1.2 13.7 7.6 11.6 1.2 14.1 8 10.6 1.3 13.3 7.2 88 7 85 165 5.2 0 5.2 5.2 12/18/2005 17:20:00 11.7 1.1 14.5 8.4 11.9 1.1 14.9 8.8 10.8 1.1 13.3 8.4 95 6 93 165 5.2 0 5.2 5 12/18/2005 17:30:00 11.4 1 14.1 8 11.6 1 14.1 8.4 10.5 1.1 13.3 6.8 101 7 107 165 5.2 0 5.2 5 12/18/2005 17:40:00 11.8 1.3 14.5 7.6 12 1.4 14.5 8 11 1.5 14.1 6.5 99 6 88 165 5.2 0 5.2 5 12/18/2005 17:50:00 12.8 1.2 16.1 8.4 13 1.2 16.1 8 12 1.4 14.9 6.8 96 6 96 165 5.2 0 5.2 5 12/18/2005 18:00:00 12.9 1.6 17.6 8.8 13.2 1.6 17.6 9.1 12.1 1.6 15.6 7.2 95 8 104 165 5.1 0 5.2 5 12/18/2005 18:10:00 12.9 2.3 17.9 7.6 13.1 2.4 18.3 7.6 12.2 2.3 17.9 7.6 106 8 105 165 4.9 0 5 4.8 12/18/2005 18:20:00 10.9 1.2 13.7 7.2 11.1 1.2 13.7 7.6 10.4 1.3 13 6.8 98 6 94 165 4.8 0 5 4.8 12/18/2005 18:30:00 11.3 1.1 13.7 7.2 11.5 1.1 14.1 7.6 10.7 1.1 13.3 7.6 93 7 98 165 5.1 0 5.2 5 12/18/2005 18:40:00 11.2 1.6 14.9 6.5 11.4 1.6 15.3 6.8 10.4 1.7 14.1 6.1 91 6 94 165 5.1 0 5.2 5 12/18/2005 18:50:00 11.4 1.1 14.5 8 11.7 1.1 15.3 8.4 10.9 1.2 14.1 8 83 6 89 165 5.1 0 5.2 5 12/18/2005 19:00:00 10.8 1.7 14.9 6.8 11 1.8 15.6 7.2 10.3 1.7 14.9 6.1 82 11 87 165 4.9 0 5 4.8 12/18/2005 19:10:00 10.7 1.5 14.1 6.5 11 1.5 14.5 6.8 10.2 1.5 13.7 6.5 89 8 84 165 4.9 0 5 4.8 12/18/2005 19:20:00 10.8 1.3 14.1 7.2 11.1 1.3 14.5 7.2 10.3 1.4 14.1 5.7 85 9 85 165 4.9 0 5 4.8 12/18/2005 19:30:00 10.3 1.5 14.5 7.2 10.5 1.5 14.9 7.2 9.9 1.4 14.5 6.8 77 8 85 165 4.7 0 5 4.8 12/18/2005 19:40:00 10.6 1.3 14.5 7.2 10.9 1.4 14.9 7.6 10.2 1.4 14.1 6.1 79 7 88 165 4.7 0 4.8 4.8 12/18/2005 19:50:00 11 1.6 14.5 8 11.2 1.7 14.9 7.6 10.4 1.6 15.3 6.8 80 7 73 165 4.6 0 4.8 4.5 12/18/2005 20:00:00 11.6 1.2 14.5 8.4 11.9 1.2 14.5 8.4 11 1.3 14.5 8 83 7 85 165 4.5 0 4.8 4.5 12/18/2005 20:10:00 11.2 1.2 14.1 7.6 11.4 1.3 14.5 8 10.7 1.2 14.1 7.2 80 8 75 165 4.5 0 4.8 4.5 12/18/2005 20:20:00 11.3 1.5 15.3 7.6 11.6 1.5 15.6 8 10.9 1.3 14.1 7.2 81 7 95 165 4.5 0 4.8 4.5 12/18/2005 20:30:00 11.7 1.3 15.3 8 12 1.4 16.1 8 11.1 1.4 14.1 8 78 6 81 165 4.6 0 4.8 4.5 12/18/2005 20:40:00 11.9 1.4 14.9 7.6 12.1 1.5 15.3 8 11.3 1.5 14.5 7.2 79 7 71 165 4.6 0 4.8 4.5 12/18/2005 20:50:00 11.9 1.2 14.9 8.4 12.1 1.3 15.3 9.1 11.3 1.2 14.1 8.4 78 7 78 165 4.6 0 4.8 4.5 12/18/2005 21:00:00 9.8 1.5 13 6.1 10 1.5 13.3 6.1 9.4 1.5 13.3 6.1 72 10 78 165 4.6 0 4.8 4.5 12/18/2005 21:10:00 9 1.4 12.2 5.7 9.1 1.5 12.2 5.7 8.6 1.5 12.6 4.9 65 9 57 165 4.6 0 4.8 4.5 12/18/2005 21:20:00 9.7 1.4 13.3 5.7 9.9 1.5 13.3 6.1 9.3 1.3 13 6.5 68 9 73 165 4.6 0 4.8 4.5 12/18/2005 21:30:00 10.4 1.5 14.1 6.5 10.6 1.5 14.5 6.5 9.9 1.5 13.7 6.1 70 8 59 165 4.6 0 4.8 4.5 12/18/2005 21:40:00 10.8 1.5 14.9 7.6 11.1 1.5 15.3 7.6 10.5 1.4 14.5 6.5 71 7 78 165 4.6 0 4.8 4.5 12/18/2005 21:50:00 12.2 1.6 16.8 8.4 12.5 1.6 17.2 8.8 11.7 1.5 15.6 7.6 74 8 69 165 4.6 0 4.8 4.5 12/18/2005 22:00:00 12.8 1.6 16.4 8.8 13 1.7 16.8 9.1 12.2 1.5 16.4 8.4 80 6 78 165 4.6 0 4.8 4.5 12/18/2005 22:10:00 12.7 1.4 16.4 9.5 13 1.4 16.4 9.9 11.9 1.4 15.3 8.8 81 7 91 165 4.6 0 4.8 4.5 12/18/2005 22:20:00 13.2 1.5 16.4 9.5 13.4 1.5 16.4 9.9 12.5 1.5 16.1 8.8 82 7 87 165 4.7 0 4.8 4.5 12/18/2005 22:30:00 13.8 1.5 17.2 9.5 14.1 1.5 17.6 9.9 13.1 1.4 16.1 8.8 84 7 84 165 4.7 0 4.8 4.8 12/18/2005 22:40:00 14.3 1.4 17.2 9.9 14.6 1.4 17.6 9.9 13.3 1.5 16.4 8 87 6 85 165 4.8 0 5 4.8 12/18/2005 22:50:00 14.7 1.3 17.2 10.3 14.9 1.4 17.6 9.9 13.5 1.5 17.2 9.5 90 6 85 165 4.9 0 5 4.8 12/18/2005 23:00:00 14.7 1.5 17.6 9.9 14.9 1.5 17.9 9.9 13.5 1.5 16.8 8.8 92 6 87 165 4.9 0 5 5 12/18/2005 23:10:00 14.7 1.5 17.9 10.3 14.9 1.5 18.3 10.3 13.7 1.7 17.2 9.5 96 6 94 165 5.1 0 5 5 12/18/2005 23:20:00 14.8 1.7 18.7 9.9 15.1 1.7 18.7 10.3 13.7 1.9 18.3 9.1 98 7 94 165 5.1 0 5.2 5 12/18/2005 23:30:00 14.8 1.5 18.3 10.3 15 1.5 18.3 10.3 13.9 1.6 17.9 9.1 103 6 85 165 5.2 0 5.2 5 12/18/2005 23:40:00 15.3 1.6 19.5 10.3 15.6 1.7 20.2 10.3 14.4 1.7 18.7 9.9 103 6 97 165 5.2 0 5.2 5 12/18/2005 23:50:00 16.4 1.2 19.1 12.6 16.7 1.3 19.9 12.6 15.4 1.5 18.7 10.3 102 5 102 165 5.2 0 5.2 5.2 12/19/2005 00:00:00 15.3 1.4 17.9 10.7 15.6 1.5 18.7 10.7 14.3 1.5 17.9 10.3 103 6 101 165 5.2 0 5.2 5 12/19/2005 00:10:00 15.3 1.8 20.2 10.7 15.6 1.9 20.6 10.7 14.3 2 19.5 9.1 103 6 104 165 5.2 0 5.5 5.2 12/19/2005 00:20:00 15.1 1.5 17.9 10.3 15.4 1.4 17.9 11.1 14.4 1.7 17.6 8.4 107 6 118 165 5.2 0 5.5 5.2 12/19/2005 00:30:00 15.2 1.6 18.7 10.7 15.5 1.6 19.5 10.7 14.3 1.7 18.3 10.3 107 6 101 165 5.2 0 5.5 5.2 12/19/2005 00:40:00 15.4 1.3 19.5 11.5 15.7 1.4 19.9 11.8 14.6 1.5 19.9 10.7 107 5 106 165 5.3 0 5.5 5.2 12/19/2005 00:50:00 16.3 1.7 20.2 10.7 16.6 1.7 20.6 10.7 15.3 2 19.5 9.5 107 6 98 165 5.4 0 5.5 5.2 12/19/2005 01:00:00 15.5 1.7 21 9.9 15.7 1.7 21 10.7 14.5 1.8 19.1 10.3 111 6 102 165 5.4 0 5.5 5.2 12/19/2005 01:10:00 15.3 1.5 18.7 11.5 15.5 1.5 18.7 10.7 14.2 1.7 18.3 9.5 108 7 110 165 5.4 0 5.5 5.5 12/19/2005 01:20:00 15.3 1.5 18.3 10.3 15.5 1.5 18.7 11.1 14.3 1.5 17.9 9.9 110 6 118 165 5.4 0 5.5 5.5 12/19/2005 01:30:00 14.7 1.3 17.9 10.7 14.9 1.3 18.3 10.7 13.8 1.7 19.1 8.8 108 6 104 165 5.4 0 5.5 5.5 12/19/2005 01:40:00 15.2 1.7 19.9 10.7 15.4 1.7 19.9 10.3 14.4 1.8 20.2 10.3 111 6 109 165 5.4 0 5.5 5.5 12/19/2005 01:50:00 15.4 1.8 20.2 10.3 15.6 1.9 21 10.3 14.6 2 19.5 10.3 112 7 115 165 5.5 0 5.7 5.5 12/19/2005 02:00:00 15.4 1.8 20.2 9.9 15.7 1.8 20.2 11.1 14.6 1.8 19.5 9.1 112 7 129 165 5.5 0 5.7 5.5 12/19/2005 02:10:00 16.1 1.7 19.9 9.5 16.4 1.9 20.2 9.9 15.3 1.8 20.6 10.3 114 7 112 165 5.5 0 5.7 5.5 12/19/2005 02:20:00 16.4 2 21.8 11.8 16.7 2.1 21.8 11.5 15.6 2.1 21 11.1 116 7 117 165 5.6 0 5.7 5.5 12/19/2005 02:30:00 16.8 2 22.1 12.2 17.1 2 22.6 12.6 16.1 2.1 21.8 11.5 116 7 121 165 5.6 0 5.7 5.5 12/19/2005 02:40:00 16.9 2 22.1 12.2 17.2 2 22.1 12.2 16.5 2.2 22.9 11.1 122 7 126 165 5.6 0 5.7 5.5 12/19/2005 02:50:00 15.9 1.8 20.2 10.7 16.2 1.9 20.6 10.7 15.5 1.9 19.9 9.5 123 7 123 165 5.7 0 5.7 5.7 12/19/2005 03:00:00 15.7 1.8 20.2 11.8 16 1.8 20.2 12.2 15.2 1.9 19.9 11.1 122 7 123 165 5.7 0 5.7 5.7 12/19/2005 03:10:00 15.8 1.8 20.6 9.9 16.1 1.8 20.6 9.5 15.4 1.8 19.9 9.5 121 7 113 165 5.7 0 5.7 5.7 12/19/2005 03:20:00 15 1.7 19.1 9.9 15.3 1.7 19.5 9.9 14.4 1.7 18.3 10.3 121 6 129 165 5.7 0 5.7 5.7 12/19/2005 03:30:00 15.6 1.7 20.6 11.1 15.9 1.7 20.6 11.5 15.1 1.8 20.2 9.9 121 6 121 165 5.7 0 5.7 5.7 12/19/2005 03:40:00 15.8 1.7 19.9 11.5 16.1 1.7 19.9 11.5 15.3 1.7 19.5 10.7 121 7 128 165 5.7 0 5.7 5.7 12/19/2005 03:50:00 16 1.7 21.4 12.6 16.3 1.7 21.4 12.6 15.5 1.8 20.2 11.8 122 6 119 165 5.7 0 5.7 5.7 12/19/2005 04:00:00 14.7 1.7 19.5 10.3 15 1.7 19.9 9.9 14.3 1.7 19.5 9.5 122 6 113 165 5.7 0 5.7 5.7 12/19/2005 04:10:00 14.5 1.7 19.9 10.3 14.7 1.7 19.9 10.7 14 1.7 17.9 9.9 122 7 116 165 5.7 0 5.7 5.7 12/19/2005 04:20:00 14.8 1.6 20.2 10.3 15.1 1.7 20.6 9.5 14.3 1.7 19.5 9.9 120 8 112 165 5.6 0 5.7 5.5 12/19/2005 04:30:00 15.3 1.5 19.5 10.3 15.6 1.5 19.9 11.1 14.8 1.7 19.5 9.5 123 7 123 165 5.6 0 5.7 5.5 12/19/2005 04:40:00 15.7 1.5 21 12.2 15.9 1.5 21 12.2 15.4 1.6 21 10.7 122 7 124 165 5.6 0 5.7 5.5 12/19/2005 04:50:00 16.2 1.5 19.9 12.2 16.4 1.5 20.2 12.6 16.1 1.7 19.9 11.5 123 7 115 165 5.6 0 5.7 5.5 12/19/2005 05:00:00 15.2 1.5 18.7 11.5 15.4 1.5 19.9 11.5 14.9 1.5 18.7 10.3 120 8 118 165 5.6 0 5.7 5.5 12/19/2005 05:10:00 16.1 1.8 21 9.1 16.4 1.9 21 9.9 15.9 2 21 10.7 122 8 123 165 5.6 0 5.7 5.5 12/19/2005 05:20:00 14.8 1.5 18.7 11.5 15.1 1.5 19.5 11.5 14.5 1.5 17.9 9.5 119 6 113 165 5.6 0 5.7 5.5 12/19/2005 05:30:00 14.5 1.5 18.3 11.1 14.7 1.5 18.7 11.5 14.2 1.6 19.5 9.5 119 8 112 165 5.6 0 5.7 5.5 12/19/2005 05:40:00 14.5 1.8 20.6 9.5 14.7 1.8 20.6 9.5 14 1.8 18.7 9.9 118 7 121 165 5.6 0 5.7 5.5 12/19/2005 05:50:00 15 2.1 20.2 9.1 15.3 2.1 20.6 9.1 14.5 2.1 20.6 9.5 118 8 116 165 5.6 0 5.7 5.5 12/19/2005 06:00:00 14.7 1.5 20.2 9.9 14.9 1.5 20.2 9.5 14.3 1.7 18.7 9.9 120 9 111 165 5.6 0 5.7 5.5 12/19/2005 06:10:00 15.1 1.9 19.5 10.7 15.3 1.9 19.9 10.7 14.7 2 19.9 9.5 117 7 111 165 5.6 0 5.7 5.5 12/19/2005 06:20:00 15.3 1.6 19.1 9.9 15.5 1.7 19.5 9.5 14.8 1.7 19.1 9.9 119 7 126 165 5.6 0 5.7 5.5 12/19/2005 06:30:00 15.2 1.5 19.1 10.7 15.4 1.5 19.5 11.1 14.7 1.7 19.1 10.3 120 8 118 165 5.6 0 5.7 5.5 12/19/2005 06:40:00 15.8 1.9 20.2 11.1 16 1.9 20.6 11.1 15.4 2 19.9 9.9 120 6 121 165 5.6 0 5.7 5.5 12/19/2005 06:50:00 15.4 1.5 20.6 11.8 15.6 1.5 20.2 11.8 15 1.6 20.2 9.9 121 7 118 165 5.6 0 5.7 5.5 12/19/2005 07:00:00 15.6 2 19.5 8.8 15.9 2.1 19.9 8.8 15.3 2.3 20.2 7.6 121 6 116 165 5.6 0 5.7 5.5 12/19/2005 07:10:00 15 1.5 18.7 10.3 15.2 1.6 19.5 10.7 14.5 1.7 18.3 9.1 121 7 121 165 5.6 0 5.7 5.5 12/19/2005 07:20:00 14.9 1.9 19.9 9.5 15.2 1.9 19.9 10.3 14.7 2.2 21 9.1 124 9 125 165 5.6 0 5.7 5.5 12/19/2005 07:30:00 14.7 1.9 21 10.7 14.9 2 21 10.7 14.3 2 21.4 8.8 125 8 122 165 5.6 0 5.7 5.5 12/19/2005 07:40:00 16 1.7 19.5 11.5 16.2 1.7 19.9 11.5 15.7 1.7 19.9 10.7 122 8 122 165 5.6 0 5.7 5.5 12/19/2005 07:50:00 15.6 1.7 21 11.5 15.8 1.7 21 11.1 15.2 1.7 20.6 10.7 123 8 117 165 5.6 0 5.7 5.5 12/19/2005 08:00:00 15.1 1.5 19.1 11.8 15.3 1.5 19.9 11.8 14.8 1.7 19.1 10.3 122 8 119 165 5.6 0 5.7 5.5 12/19/2005 08:10:00 15.8 1.8 22.1 12.2 16 1.8 22.6 12.6 15.4 2 21.8 10.7 124 8 118 165 5.6 0 5.7 5.5 12/19/2005 08:20:00 14.8 1.6 19.5 9.9 15 1.7 19.5 10.3 14.5 1.8 19.5 8.8 128 8 137 165 5.5 0 5.7 5.5 12/19/2005 08:30:00 15.4 1.6 19.1 10.3 15.5 1.6 19.5 10.7 15 1.7 19.5 9.9 130 8 116 165 5.5 0 5.7 5.5 12/19/2005 08:40:00 15 2.1 21.4 10.7 15.1 2.1 21 10.7 14.8 2.3 21.4 9.9 131 8 136 165 5.5 0 5.7 5.5 12/19/2005 08:50:00 13.7 1.3 17.2 10.3 13.8 1.3 17.6 10.7 13.3 1.5 16.8 8.4 130 8 118 165 5.5 0 5.7 5.5 12/19/2005 09:00:00 14.5 1.5 17.9 9.1 14.6 1.6 17.9 9.5 14.1 1.7 18.3 9.5 127 8 121 165 5.5 0 5.7 5.5 12/19/2005 09:10:00 14.3 1.8 19.9 9.5 14.5 1.8 19.5 9.5 13.9 2 19.1 9.1 131 7 136 165 5.5 0 5.7 5.5 12/19/2005 09:20:00 14.7 1.6 19.1 10.7 14.9 1.6 19.1 10.7 14.1 1.8 19.1 10.3 131 9 127 165 5.5 0 5.7 5.5 12/19/2005 09:30:00 14.5 1.6 18.3 9.5 14.7 1.7 18.7 9.1 14.1 1.9 18.3 8.8 131 8 133 165 5.5 0 5.7 5.5 12/19/2005 09:40:00 14.5 1.5 18.3 10.7 14.7 1.5 18.3 11.1 14.1 1.5 18.3 10.3 128 8 126 165 5.4 0 5.5 5.5 12/19/2005 09:50:00 15.3 1.6 19.5 11.1 15.4 1.7 19.9 10.7 14.9 1.9 19.9 9.9 129 8 126 165 5.4 0 5.5 5.2 12/19/2005 10:00:00 14.8 1.4 18.7 11.1 15 1.5 18.7 11.1 14.3 1.7 18.7 10.7 129 7 128 165 5.3 0 5.5 5.2 12/19/2005 10:10:00 14.7 2 20.2 9.5 15 2 20.2 9.5 14.4 2.1 20.6 9.5 128 8 113 165 5.3 0 5.5 5.2 12/19/2005 10:20:00 14.6 1.3 17.9 11.5 14.7 1.4 17.9 10.3 14 1.6 18.3 9.5 130 7 119 165 5.2 0 5.5 5.2 12/19/2005 10:30:00 14.4 1.7 18.7 10.3 14.6 1.6 19.1 11.1 14.2 1.7 18.7 9.9 130 7 124 165 5.2 0 5.5 5.2 12/19/2005 10:40:00 15 1.6 19.5 10.7 15.2 1.5 19.5 11.1 14.8 1.9 20.2 10.3 130 8 140 165 5.2 0 5.5 5.2 12/19/2005 10:50:00 14.3 1.8 19.9 8.8 14.5 1.8 19.9 8.8 13.9 1.9 19.5 9.5 129 8 129 165 5.2 0 5.5 5.2 12/19/2005 11:00:00 14.8 2 20.2 9.9 14.9 2 20.6 10.3 14.5 2.1 20.6 9.9 130 8 127 165 5.2 0 5.7 5.2 12/19/2005 11:10:00 13.8 1.5 18.3 9.9 13.9 1.6 17.9 10.7 13.5 1.7 17.9 9.5 130 8 128 165 5.2 0 5.5 5.2 12/19/2005 11:20:00 13.7 1.5 17.9 9.9 13.9 1.6 17.9 9.9 13.5 1.6 17.2 9.5 130 9 128 165 5.2 0 5.2 5.2 12/19/2005 11:30:00 13.3 1.6 17.9 8.4 13.4 1.6 18.7 8.8 13 1.6 17.2 9.1 130 8 129 165 5.2 0 5.2 5.2 12/19/2005 11:40:00 12.8 1.5 16.8 9.5 12.9 1.5 17.2 9.9 12.5 1.7 17.6 7.6 127 10 126 165 5.2 0 5.5 5.2 12/19/2005 11:50:00 12.8 1.5 16.4 8.8 12.9 1.5 17.2 9.1 12.5 1.7 17.6 8.8 128 8 115 165 5.2 0 5.5 5.2 12/19/2005 12:00:00 12 1.6 16.8 8.8 12.1 1.6 17.2 8.8 11.6 1.7 16.4 7.2 128 9 120 165 5.2 0 5.5 5.2 12/19/2005 12:10:00 12.6 1.6 17.2 8 12.8 1.6 17.6 8 12.4 1.7 17.2 8 125 9 111 165 5.2 0 5.5 5.2 12/19/2005 12:20:00 12.2 1.6 16.1 8.4 12.4 1.7 16.1 8.4 11.9 1.7 16.1 8 125 9 121 165 5.2 0 5.5 5.2 12/19/2005 12:30:00 12.3 1.6 16.8 8.4 12.4 1.6 17.2 7.2 11.9 1.7 16.8 5.7 123 10 139 165 5.2 0 5.5 5.2 12/19/2005 12:40:00 12.1 1.1 16.4 9.1 12.2 1.1 16.1 9.5 11.8 1.1 15.3 8 124 8 112 165 5.2 0 5.2 5.2 12/19/2005 12:50:00 12.3 1.3 15.6 9.1 12.5 1.3 15.6 9.1 12.1 1.4 15.6 8.4 126 8 129 165 5.2 0 5.2 5.2 12/19/2005 13:00:00 12.6 1.7 18.3 8.8 12.7 1.7 17.9 9.1 12.4 1.9 18.3 7.6 130 8 137 165 5.2 0 5.5 5.2 12/19/2005 13:10:00 11.7 1.3 15.6 8 11.8 1.3 15.6 7.6 11.3 1.5 14.9 6.8 126 9 117 165 5.2 0 5.5 5.2 12/19/2005 13:20:00 11.3 1.2 14.5 7.2 11.5 1.2 14.5 7.6 11.2 1.3 14.1 7.2 124 7 119 165 5.2 0 5.2 5.2 12/19/2005 13:30:00 10.4 1.1 13.3 7.2 10.5 1.1 13.3 7.2 10 1.2 13 6.5 125 7 138 165 5.2 0 5.2 5.2 12/19/2005 13:40:00 10.6 1.3 14.5 7.6 10.8 1.3 14.5 7.6 10.4 1.2 13.3 6.8 127 8 114 165 5.2 0 5.5 5.2 12/19/2005 13:50:00 10.7 1 13.3 8 10.8 1 13.7 8 10.4 1.1 13.3 7.6 126 8 135 165 5.2 0 5.2 5.2 12/19/2005 14:00:00 11.1 1.2 13.7 8 11.3 1.2 14.1 8 10.8 1.3 14.1 7.2 121 6 121 165 5.2 0 5.5 5.2 12/19/2005 14:10:00 10.6 1.5 14.5 7.2 10.8 1.5 14.9 7.6 10.1 1.5 14.1 6.5 118 8 107 165 5.2 0 5.2 5.2 12/19/2005 14:20:00 10.3 1.2 13 6.5 10.6 1.2 13.3 6.5 9.9 1.3 12.6 5.7 116 7 122 165 5.2 0 5.2 5 12/19/2005 14:30:00 10.6 1.2 13.3 7.6 10.8 1.2 13.3 7.6 10.2 1.2 13 6.8 117 8 114 165 5.2 0 5.2 5 12/19/2005 14:40:00 9.6 1.2 14.1 6.1 9.8 1.2 14.5 6.1 9.1 1.3 11.8 5.7 113 8 110 165 5.2 0 5.2 5 12/19/2005 14:50:00 9.6 1.1 13 6.5 9.8 1 13.3 6.8 9.2 1.1 11.8 5.3 113 7 118 165 5.2 0 5.2 5 12/19/2005 15:00:00 9 0.7 11.5 6.8 9.2 0.8 11.8 7.2 8.5 0.9 10.7 5.7 110 6 118 165 5.2 0 5.2 5 12/19/2005 15:10:00 9.7 0.8 12.2 6.5 9.9 0.8 12.6 6.5 9.3 0.8 11.8 7.2 109 6 98 165 5.2 0 5.2 5 12/19/2005 15:20:00 9.5 0.9 11.5 7.2 9.8 0.9 11.8 7.2 9.2 1 11.8 6.1 107 6 106 165 5.2 0 5.2 5 12/19/2005 15:30:00 9.2 0.8 11.5 6.8 9.5 0.9 11.8 6.8 8.7 1 11.8 5.7 106 6 100 165 5.2 0 5.2 5 12/19/2005 15:40:00 9.4 0.8 11.5 6.5 9.6 0.8 12.2 7.2 9 1 11.1 6.5 102 6 101 165 5.1 0 5.2 5 12/19/2005 15:50:00 9.4 0.9 11.5 6.1 9.7 1 11.8 5.7 8.8 1.1 11.5 5.3 101 7 91 165 5.1 0 5.2 5 12/19/2005 16:00:00 9.2 1 11.8 6.5 9.5 1 12.2 6.5 8.7 1.1 11.5 5.3 101 6 89 165 5.1 0 5.2 5 12/19/2005 16:10:00 9.1 1 11.5 6.1 9.4 1 11.5 6.8 8.4 1.2 11.1 5.3 99 6 104 165 5.1 0 5.2 5 12/19/2005 16:20:00 9.2 1.1 11.5 6.1 9.5 1.1 11.8 6.1 8.6 1.2 11.1 5.3 99 6 97 165 5.1 0 5.2 5 12/19/2005 16:30:00 9.8 0.9 11.8 6.8 10 0.9 11.8 7.2 9.1 1 11.5 6.5 99 6 97 165 5.1 0 5.2 5 12/19/2005 16:40:00 9.4 0.9 11.1 6.1 9.7 0.9 11.8 6.1 8.8 1.1 11.1 5.7 99 6 94 165 5.1 0 5.2 5 12/19/2005 16:50:00 9.8 1 11.8 5.7 10 1 12.2 5.7 9 1.2 11.8 5.7 98 6 96 165 5.1 0 5.2 5 12/19/2005 17:00:00 9.2 0.8 11.1 6.8 9.5 0.8 11.5 7.2 8.8 1 11.1 6.1 101 6 106 165 5.1 0 5.2 5 12/19/2005 17:10:00 9.2 1 11.5 5.3 9.5 1 11.5 5.7 8.8 1.2 11.5 5.3 102 6 99 165 5.1 0 5 5 12/19/2005 17:20:00 8.9 1.1 11.1 5.3 9.1 1.1 11.8 5.7 8.3 1.1 11.1 5.7 102 6 105 165 5 0 5 5 12/19/2005 17:30:00 9.4 1 11.8 6.1 9.6 1 11.8 6.1 8.9 1.1 11.5 5.7 103 6 110 165 5.1 0 5 4.8 12/19/2005 17:40:00 9.4 1 11.8 6.8 9.6 1 11.8 6.8 9 1 11.5 5.3 112 7 98 165 5.1 0 5.2 5 12/19/2005 17:50:00 8.2 0.8 10.3 6.1 8.4 0.8 11.1 6.1 8 0.8 10.3 6.1 119 8 99 165 5.1 0 5.2 5 12/19/2005 18:00:00 8.8 1.1 11.1 6.5 9 1 11.1 6.8 8.6 1.1 11.1 5.3 125 7 120 165 5.1 0 5.2 5 12/19/2005 18:10:00 10 1 12.2 7.2 10 1 12.2 8 9.8 1.1 12.6 7.2 132 7 125 165 5.1 0 5.2 5 12/19/2005 18:20:00 10.2 0.9 13 8 10.2 0.9 12.6 8 9.8 1 13 6.8 134 7 140 165 5.1 0 5.2 5 12/19/2005 18:30:00 10.5 1.3 13.7 6.8 10.6 1.3 13.7 6.8 10.3 1.5 13.3 7.6 135 7 138 165 5.1 0 5.2 5 12/19/2005 18:40:00 10.5 1.3 14.5 7.6 10.6 1.3 14.1 7.6 10.2 1.3 14.5 7.2 134 8 135 165 5.1 0 5.2 5 12/19/2005 18:50:00 10.8 1.2 14.5 7.6 10.9 1.2 14.5 7.6 10.7 1.3 14.5 6.5 135 8 132 165 5.1 0 5 5 12/19/2005 19:00:00 9.4 1.5 13 5.3 9.5 1.4 13 6.1 9.4 1.6 13.3 5.7 137 10 147 165 5.1 0 5 5 12/19/2005 19:10:00 10.3 1.2 13.7 7.2 10.3 1.2 13.3 7.2 10.2 1.3 13.3 7.2 133 9 135 165 4.9 0 5 4.8 12/19/2005 19:20:00 9.1 1.1 11.8 6.5 9.1 1.1 11.8 6.5 9 1.1 11.8 6.5 137 9 117 165 4.9 0 5 4.8 12/19/2005 19:30:00 8.2 1.3 11.8 5.3 8.2 1.3 11.5 5.3 8.3 1.3 12.2 5.3 142 8 152 165 4.9 0 5 4.8 12/19/2005 19:40:00 8.6 1.3 11.8 5.7 8.7 1.3 11.8 6.1 8.4 1.3 11.1 5.7 123 8 122 165 4.9 0 5 4.8 12/19/2005 19:50:00 10 1.1 12.2 6.8 10.1 1.1 12.6 7.2 9.7 1.2 12.2 5.7 124 7 118 165 4.8 0 5 4.8 12/19/2005 20:00:00 9.9 0.9 12.2 7.6 9.9 0.9 12.2 7.6 9.8 1 12.2 7.6 127 7 125 165 4.7 0 4.8 4.5 12/19/2005 20:10:00 8.6 0.7 10.3 6.8 8.6 0.8 10.3 6.8 8.3 0.9 10.3 5.7 129 7 133 165 4.6 0 4.8 4.5 12/19/2005 20:20:00 7.9 0.8 10.7 6.1 8 0.8 10.7 6.1 7.6 0.7 9.9 5.7 125 8 130 165 4.6 0 4.8 4.5 12/19/2005 20:30:00 7.7 0.8 10.3 5.3 7.9 0.8 10.3 5.7 7.5 1 10.7 4.9 120 6 112 165 4.4 0 4.8 4.3 12/19/2005 20:40:00 7.1 0.7 9.5 5.3 7.3 0.7 9.5 5.3 7 0.8 9.1 4.2 121 6 128 165 4.4 0 4.5 4.3 12/19/2005 20:50:00 6.5 0.7 8 4.6 6.7 0.7 8 4.6 6.3 0.7 8.8 4.6 109 8 110 165 4.5 0 4.5 4.5 12/19/2005 21:00:00 8.1 1 10.7 4.6 8.3 1 10.7 5.3 7.6 1 9.9 4.6 106 7 98 165 4.4 0 4.5 4.3 12/19/2005 21:10:00 8.7 0.8 10.7 6.5 8.9 0.7 11.1 6.8 8.2 0.8 10.3 5.7 105 5 108 165 4.3 0 4.5 4.3 12/19/2005 21:20:00 8.2 0.7 9.9 6.1 8.3 0.7 9.9 5.7 7.7 0.8 9.9 5.3 107 5 112 165 4.1 0 4.3 4.3 12/19/2005 21:30:00 7.6 0.9 9.5 5.3 7.7 0.9 9.5 5.3 7.1 0.9 9.5 4.9 106 5 97 165 4.2 0 4.5 4.3 12/19/2005 21:40:00 7.6 0.7 9.9 5.7 7.8 0.8 9.9 5.3 7.2 0.8 9.1 4.6 106 6 114 165 4.1 0 4.3 4 12/19/2005 21:50:00 7.6 0.6 9.9 6.1 7.7 0.6 9.9 5.7 7.2 0.8 9.1 5.3 105 5 92 165 4.1 0 4.3 4 12/19/2005 22:00:00 7.6 0.9 9.5 4.2 7.8 0.8 9.5 4.6 7.3 0.9 9.5 4.9 99 6 96 165 4.1 0 4.3 4 12/19/2005 22:10:00 7.8 0.9 9.5 5.3 8 0.9 9.9 5.7 7.4 1 9.5 4.9 95 6 93 165 4.1 0 4.3 3.8 12/19/2005 22:20:00 7.8 0.8 9.1 4.9 8 0.8 9.5 5.3 7.4 0.8 9.1 4.9 96 5 97 165 3.9 0 4.3 3.8 12/19/2005 22:30:00 7.3 0.6 9.1 5.3 7.5 0.6 9.5 5.7 6.9 0.7 8.8 4.9 94 6 90 165 3.8 0 4 3.5 12/19/2005 22:40:00 7.2 0.8 8.8 5.3 7.3 0.8 9.1 5.3 6.6 0.9 8.8 4.6 98 6 102 165 3.7 0 3.8 3.5 12/19/2005 22:50:00 7.6 0.7 9.5 5.7 7.8 0.7 9.5 5.7 7.2 0.9 9.1 4.9 97 6 110 165 3.6 0 3.8 3.5 12/19/2005 23:00:00 7 0.8 8.8 4.9 7.2 0.8 9.1 5.3 6.7 0.9 8.8 4.6 96 6 88 165 3.5 0 3.8 3.3 12/19/2005 23:10:00 6.4 0.8 8.4 4.9 6.6 0.8 8.8 4.9 6.1 0.9 8 4.2 97 6 99 165 3.3 0 3.5 3.3 12/19/2005 23:20:00 6.2 0.7 8 4.2 6.4 0.7 8 4.6 5.7 0.7 7.2 3.8 95 6 105 165 3.2 0 3.3 3 12/19/2005 23:30:00 6 0.7 7.2 3.4 6.2 0.7 7.6 3.4 5.6 0.7 7.2 3.8 89 4 97 165 3.2 0 3.3 3.3 12/19/2005 23:40:00 7.2 0.7 8.4 4.9 7.4 0.7 8.8 5.3 6.9 0.7 8.4 4.6 89 6 85 165 3.3 0 3.5 3.3 12/19/2005 23:50:00 7.5 1 9.9 4.9 7.7 1 10.3 5.3 7.2 0.9 9.5 4.9 83 6 85 165 3.1 0.1 3.3 3 12/20/2005 00:00:00 7.6 0.8 9.5 6.1 7.7 0.9 9.5 5.7 7.1 0.9 9.1 5.3 84 6 86 165 3 0 3.3 2.8 12/20/2005 00:10:00 7.4 0.6 9.1 5.3 7.6 0.7 9.5 5.7 7 0.8 8.8 4.9 85 6 87 165 2.9 0 3 2.8 12/20/2005 00:20:00 7.3 0.9 9.5 5.3 7.5 0.9 9.5 4.9 6.9 0.9 8.8 4.6 86 8 88 165 2.9 0 2.8 2.8 12/20/2005 00:30:00 7.1 0.6 8.8 4.9 7.4 0.6 8.8 4.9 6.9 0.6 8.8 4.9 85 9 102 165 2.8 0 2.8 2.6 12/20/2005 00:40:00 6.6 0.7 8.4 4.9 6.9 0.7 8.8 4.9 6.5 0.7 8.4 4.9 77 5 80 165 2.7 0 2.8 2.6 12/20/2005 00:50:00 7.4 0.6 9.1 5.7 7.7 0.7 9.1 6.1 7.2 0.7 8.8 5.7 79 5 76 165 2.9 0 3 2.8 12/20/2005 01:00:00 6.4 0.8 8.4 4.6 6.6 0.7 8.4 4.6 6 0.8 8 4.2 72 7 71 165 2.9 0 3 2.8 12/20/2005 01:10:00 5.9 0.7 7.6 3.4 6.1 0.7 8 3.8 5.6 0.7 7.2 3.8 71 8 75 165 2.7 0 2.8 2.6 12/20/2005 01:20:00 6 1.1 8.4 4.2 6.2 1.1 8.8 4.2 5.9 1 8.4 4.2 79 6 77 165 2.4 0 2.8 2.3 12/20/2005 01:30:00 6.4 0.9 8.8 3.8 6.6 1 8.8 4.2 6.1 0.9 8 3.8 74 7 67 165 2.5 0 2.8 2.3 12/20/2005 01:40:00 6 0.8 8 3.8 6.2 0.9 8.4 4.2 5.8 0.8 8.8 3.8 82 8 87 165 2.7 0 2.8 2.6 12/20/2005 01:50:00 6.3 1.3 9.1 3.8 6.4 1.3 9.1 3.8 6 1.2 9.1 3.8 81 7 73 165 2.5 0 2.8 2.6 12/20/2005 02:00:00 6.2 0.8 8 3.8 6.4 0.9 8.4 3.8 5.9 0.8 7.6 4.2 80 9 84 165 2.7 0 2.8 2.6 12/20/2005 02:10:00 6.7 0.5 7.6 5.3 6.9 0.5 8 5.3 6.4 0.6 7.6 4.2 82 5 82 165 2.9 0 3 2.8 12/20/2005 02:20:00 6.2 0.7 8 4.6 6.4 0.7 8 4.6 6.1 0.7 8.4 4.2 81 5 88 165 2.9 0 3 2.8 12/20/2005 02:30:00 6.3 0.8 8 4.2 6.5 0.8 8.4 4.2 6.1 0.8 8 4.2 83 6 83 165 2.9 0 3 2.8 12/20/2005 02:40:00 5.2 0.6 6.5 3.4 5.5 0.6 6.8 3.4 5 0.6 6.8 3 70 6 78 165 2.7 0 2.8 2.6 12/20/2005 02:50:00 5.4 0.8 7.2 3.8 5.6 0.8 7.6 3.8 5.1 0.7 6.8 3.4 72 6 74 165 2.7 0 2.8 2.8 12/20/2005 03:00:00 6.1 0.9 8.8 4.2 6.3 0.9 9.1 4.2 5.7 0.8 8.4 3.8 65 8 68 165 2.7 0 3 2.6 12/20/2005 03:10:00 6.5 0.8 8.8 4.2 6.7 0.8 8.8 4.6 6.1 0.8 8.8 4.2 60 8 57 165 2.7 0 2.8 2.8 12/20/2005 03:20:00 6.1 0.7 7.6 4.6 6.2 0.8 7.6 4.6 5.8 0.6 7.6 4.2 57 7 54 165 2.7 0 2.8 2.8 12/20/2005 03:30:00 5.8 0.9 8 3.8 6 0.9 8 3.8 5.6 0.8 8 3.4 66 8 56 165 2.7 0 2.8 2.6 12/20/2005 03:40:00 5.9 0.7 7.6 4.2 6.1 0.7 8.4 4.6 5.5 0.7 7.6 3.4 66 7 58 165 2.7 0 2.8 2.6 12/20/2005 03:50:00 5.7 0.6 7.6 3.8 5.9 0.6 7.6 4.2 5.3 0.7 6.8 3.8 65 5 68 165 2.6 0 2.8 2.6 12/20/2005 04:00:00 6.1 0.6 7.6 4.2 6.2 0.6 7.6 4.2 5.6 0.7 7.2 3.4 54 7 46 165 2.7 0 2.8 2.6 12/20/2005 04:10:00 6.7 0.5 8 4.9 6.7 0.6 8 4.6 6.1 0.6 7.6 4.6 42 4 43 165 2.7 0 2.8 2.8 12/20/2005 04:20:00 7.2 0.7 9.1 4.9 7.2 0.8 9.5 4.9 6.5 0.8 8.8 4.2 43 7 48 165 2.7 0 2.8 2.8 12/20/2005 04:30:00 6.5 1.1 9.5 3.8 6.7 1.1 9.5 4.2 6.2 1 8.8 3.8 68 11 85 165 2.8 0 2.8 2.8 12/20/2005 04:40:00 6.5 1.1 9.5 3.4 6.7 1.1 9.5 3.4 6.3 1 9.1 3.8 65 10 68 165 2.6 0 2.8 2.6 12/20/2005 04:50:00 6.5 1 8.8 3.8 6.6 1 8.8 4.2 6.3 1 8.8 4.2 69 10 52 165 2.5 0 2.8 2.6 12/20/2005 05:00:00 7 0.8 9.1 5.3 7.2 0.8 9.1 5.3 6.8 0.9 9.1 4.6 73 7 73 165 2.4 0 2.6 2.3 12/20/2005 05:10:00 5.6 0.8 7.6 3.4 5.8 0.8 8 4.2 5.5 0.8 7.6 3 75 9 85 165 2.2 0 2.6 2.1 12/20/2005 05:20:00 5.7 0.9 8.4 3.8 5.8 0.9 8.4 3.8 5.6 0.8 7.6 3.8 82 7 88 165 2.1 0 2.3 1.8 12/20/2005 05:30:00 4.9 0.8 7.2 3 5 0.8 7.2 3.4 4.8 0.8 7.6 3 73 9 75 165 2.1 0 2.3 2.1 12/20/2005 05:40:00 5.2 0.8 7.2 3.4 5.3 0.8 7.2 3.4 5.3 0.8 7.2 3.8 66 9 74 165 2.2 0 2.3 2.1 12/20/2005 05:50:00 4.5 0.7 6.1 2.6 4.6 0.7 6.1 2.6 4.3 0.7 6.1 3 62 8 55 165 2.3 0 2.3 2.3 12/20/2005 06:00:00 4.6 0.7 6.1 2.6 4.7 0.7 6.5 3 4.2 0.7 6.5 2.6 55 8 57 165 2.3 0 2.6 2.3 12/20/2005 06:10:00 4.1 0.6 5.3 2.3 4.2 0.6 5.3 2.3 3.8 0.6 5.3 2.3 49 7 58 165 2.3 0 2.6 2.3 12/20/2005 06:20:00 4.6 0.6 6.1 2.6 4.6 0.6 6.1 2.6 4.1 0.6 6.1 2.6 46 6 43 165 2.3 0 2.6 2.3 12/20/2005 06:30:00 5.3 0.6 6.8 3.4 5.3 0.6 6.8 3 4.8 0.7 6.5 2.6 47 5 52 165 2.3 0 2.6 2.3 12/20/2005 06:40:00 5.3 0.7 6.8 3.8 5.4 0.7 6.8 3.8 4.9 0.6 6.5 3 52 5 53 165 2.4 0 2.6 2.3 12/20/2005 06:50:00 5.2 0.5 6.1 3.4 5.4 0.5 6.5 3.8 4.9 0.6 6.1 3.4 54 5 46 165 2.4 0 2.6 2.3 12/20/2005 07:00:00 5.6 0.4 6.5 4.2 5.6 0.4 6.5 4.2 5.3 0.5 6.5 3.8 39 5 34 165 2.4 0 2.6 2.3 12/20/2005 07:10:00 5.3 0.4 6.1 3.8 5.3 0.5 6.1 3.8 5.1 0.6 6.5 3 34 4 32 165 2.4 0 2.6 2.3 12/20/2005 07:20:00 5.3 0.4 6.5 3.4 5.3 0.4 6.5 3.4 5.1 0.4 6.1 3.4 29 3 31 165 2.4 0 2.6 2.3 12/20/2005 07:30:00 5.5 0.4 6.5 4.2 5.5 0.5 6.5 3.4 5.3 0.5 6.1 3.4 28 5 26 165 2.4 0 2.6 2.6 12/20/2005 07:40:00 5.2 0.5 6.5 3.8 5 0.5 6.5 3.8 4.8 0.5 6.1 3.4 23 5 23 165 2.4 0 2.6 2.3 12/20/2005 07:50:00 5 0.4 6.5 3.8 4.8 0.5 6.5 3 4.7 0.6 6.5 3.4 22 5 25 165 2.4 0 2.6 2.3 12/20/2005 08:00:00 6.1 0.6 7.6 4.6 5.6 0.6 7.2 3 5.9 0.6 7.2 4.6 18 5 20 165 2.5 0 2.6 2.6 12/20/2005 08:10:00 5.6 0.5 6.8 3.8 5.1 0.6 6.8 2.6 5.3 0.6 6.5 3.4 17 5 12 165 2.5 0 2.6 2.6 12/20/2005 08:20:00 5.7 0.5 7.2 4.2 5.3 0.8 7.2 2.6 5.5 0.6 7.2 3.8 18 6 26 165 2.6 0 2.8 2.6 12/20/2005 08:30:00 5.5 0.7 7.6 3.4 4.8 0.8 6.5 2.3 5.3 0.8 6.8 3 14 6 11 165 2.7 0 2.8 2.6 12/20/2005 08:40:00 5.6 0.8 7.2 3.4 5.1 0.8 6.8 2.3 5.4 0.8 7.6 3.4 19 8 19 165 2.7 0 2.8 2.8 12/20/2005 08:50:00 5.1 0.5 6.5 3.8 4.5 0.7 6.1 2.3 4.9 0.5 6.5 3.8 15 5 15 165 2.8 0 2.8 2.8 12/20/2005 09:00:00 4.4 0.7 6.1 2.6 3.9 0.8 6.1 1.9 4.2 0.7 6.1 2.6 18 7 22 165 2.8 0 2.8 2.8 12/20/2005 09:10:00 5.2 0.7 6.8 3.4 4.6 0.7 6.1 2.3 4.9 0.7 6.5 2.6 16 7 14 165 2.9 0 3 2.8 12/20/2005 09:20:00 5.6 1 8.4 3.4 4.7 1.1 7.6 2.3 5.3 1.1 8.4 3.4 12 7 12 165 2.9 0 2.8 2.8 12/20/2005 09:30:00 7.3 0.6 9.1 5.3 6.3 1.1 8.8 3.4 7 0.8 8.8 4.9 11 9 12 165 2.7 0 2.8 2.6 12/20/2005 09:40:00 6.4 0.8 8.4 4.6 5.2 1.3 9.1 2.3 6.3 0.7 8 4.6 352 7 343 165 2.6 0 2.8 2.6 12/20/2005 09:50:00 7.7 1.3 11.1 4.9 6 1.7 10.7 1.5 7.4 1.2 10.3 4.6 8 7 18 165 2.5 0 2.8 2.3 12/20/2005 10:00:00 7.8 1 10.3 4.6 5.7 1.6 9.5 3 7.7 1 10.7 5.3 7 7 16 165 2.7 0 2.8 2.6 12/20/2005 10:10:00 7.8 0.9 9.9 5.7 6 1.7 8.8 3 7.6 0.9 9.5 5.7 9 6 15 165 2.8 0 2.8 2.8 12/20/2005 10:20:00 7.5 0.7 9.1 5.7 5.8 1.2 8.8 3.4 7.5 0.8 9.5 4.6 10 5 9 165 2.9 0 3 2.8 12/20/2005 10:30:00 8.6 0.6 9.9 6.1 6.4 1.2 8.8 4.2 8.5 0.7 10.3 6.1 8 5 0 165 3 0 3.3 3 12/20/2005 10:40:00 8.3 0.7 10.3 6.5 6.7 1.4 9.1 3.8 8.2 0.9 10.7 5.7 11 8 18 165 3.1 0 3.3 3 12/20/2005 10:50:00 7.4 1 9.9 5.3 5.8 1.3 9.5 3 7.3 1.1 9.5 4.6 10 8 15 165 3.2 0 3.3 3 12/20/2005 11:00:00 8.3 1 12.2 6.1 6.6 1.4 10.7 3.4 8.1 1.1 11.8 5.7 9 7 9 165 3.3 0 3.5 3.3 12/20/2005 11:10:00 8.2 1.2 10.7 4.6 6.6 1.4 10.3 3.4 8.1 1.2 10.7 4.9 10 6 12 165 3.2 0 3.3 3 12/20/2005 11:20:00 5.7 1.3 8.8 3 5.4 1.2 8.4 2.6 5.3 1.3 8.8 2.3 24 17 30 165 3.3 0 3.5 3.3 12/20/2005 11:30:00 3.9 0.9 6.1 1.9 4 0.9 6.1 1.9 3.7 0.9 6.5 1.9 55 21 29 165 3.3 0 3.5 3.3 12/20/2005 11:40:00 6.2 1.4 10.3 3 6.3 1.4 10.3 3 6 1.3 9.9 2.6 66 9 48 165 2.9 0 3.3 2.8 12/20/2005 11:50:00 6 1.4 9.9 3.8 6.1 1.4 10.3 3.8 5.8 1.3 9.9 3 64 14 94 165 2.8 0 3 2.6 12/20/2005 12:00:00 7.1 1 9.9 4.6 7.2 1 9.9 4.6 6.8 1 9.5 4.6 83 5 89 165 2.3 0 2.6 2.3 12/20/2005 12:10:00 6.5 1 9.5 4.6 6.7 1.1 9.5 4.6 6.3 1 8.8 4.2 69 8 81 165 2.6 0 2.8 2.3 12/20/2005 12:20:00 5.1 0.8 7.2 3.4 5.2 0.8 7.2 3 4.9 0.7 6.8 3 67 9 72 165 2.7 0 2.8 2.6 12/20/2005 12:30:00 6.3 0.7 8.4 4.6 6.5 0.7 8.4 4.9 6.1 0.6 8 4.6 73 8 73 165 2.8 0 2.8 2.8 12/20/2005 12:40:00 6.4 1 8.8 4.2 6.6 1 9.1 4.6 6.1 1 8.4 3.4 71 8 74 165 2.9 0 3 2.8 12/20/2005 12:50:00 5.2 0.7 6.8 3.4 5.3 0.7 7.2 3.4 5 0.7 6.8 3.4 71 8 75 165 2.9 0 3 2.8 12/20/2005 13:00:00 5.2 0.8 7.2 3.4 5.3 0.8 7.2 3.4 5 0.7 6.8 3 72 8 71 165 3 0 3 2.8 12/20/2005 13:10:00 4.6 0.7 7.2 2.6 4.7 0.8 7.6 2.6 4.5 0.7 6.1 1.9 66 9 52 165 2.9 0 3 2.8 12/20/2005 13:20:00 5.9 0.9 8 3 5.8 1 8 3 5.5 0.9 8 3 43 8 63 165 2.7 0 2.8 2.6 12/20/2005 13:30:00 4.5 0.7 6.5 2.6 4.4 0.7 6.1 2.6 4.2 0.7 5.7 2.6 36 8 37 165 2.7 0 2.8 2.6 12/20/2005 13:40:00 4.4 0.5 5.3 2.6 4.3 0.5 5.3 2.3 4.2 0.6 5.3 2.6 32 6 28 165 2.7 0 2.8 2.6 12/20/2005 13:50:00 4.6 0.4 5.7 3.4 4.5 0.5 5.3 2.6 4.4 0.5 5.3 2.6 28 6 33 165 2.7 0 2.8 2.6 12/20/2005 14:00:00 4.4 0.7 6.1 2.6 4.2 0.7 6.1 2.3 4.2 0.7 6.1 2.3 26 7 32 165 2.7 0 2.8 2.6 12/20/2005 14:10:00 4.5 0.5 5.7 3 4.4 0.5 5.7 2.6 4.3 0.6 5.7 2.3 30 5 22 165 2.8 0 2.8 2.6 12/20/2005 14:20:00 4.4 0.5 6.1 3 4.3 0.6 6.1 2.6 4.1 0.5 5.3 2.6 35 6 44 165 2.9 0 2.8 2.8 12/20/2005 14:30:00 4.9 0.7 6.5 3 4.9 0.8 6.8 2.6 4.7 0.6 6.5 3 46 9 50 165 2.9 0 2.8 2.8 12/20/2005 14:40:00 5.4 0.7 6.8 3.4 5.5 0.7 6.8 3.4 5.1 0.7 6.8 3.4 53 6 52 165 2.9 0 3 2.8 12/20/2005 14:50:00 6 0.6 7.2 3.8 6.1 0.7 7.6 4.2 5.5 0.7 7.6 3.8 53 7 46 165 2.8 0 2.8 2.8 12/20/2005 15:00:00 5.7 0.5 6.8 4.2 5.8 0.5 6.8 4.2 5.2 0.6 6.5 3.8 44 5 52 165 2.7 0 2.8 2.6 12/20/2005 15:10:00 5.2 0.4 6.1 3.8 5.3 0.4 6.1 3.4 4.8 0.5 6.1 2.6 42 3 43 165 2.7 0 2.8 2.6 12/20/2005 15:20:00 5.4 0.4 6.5 3.8 5.5 0.4 6.5 3.8 5.1 0.5 6.1 3.4 41 6 32 165 2.8 0 2.8 2.8 12/20/2005 15:30:00 5.9 0.5 7.2 4.9 5.8 0.5 7.2 4.6 5.6 0.6 7.2 3.8 29 6 31 165 2.7 0 2.8 2.6 12/20/2005 15:40:00 6.1 0.5 7.2 5.3 5.6 0.5 6.8 4.2 6.1 0.6 7.6 4.6 16 3 18 165 2.7 0 2.8 2.6 12/20/2005 15:50:00 7.5 0.5 8.4 6.1 4.8 0.8 7.2 3 7.5 0.5 8.8 6.1 7 3 6 165 2.5 0 2.8 2.6 12/20/2005 16:00:00 7.1 0.7 8.8 5.3 5.5 0.9 7.2 3.4 6.9 0.6 8.4 5.3 11 5 3 165 2.5 0 2.8 2.6 12/20/2005 16:10:00 5.9 0.5 7.2 4.2 5 0.8 6.8 2.6 5.6 0.6 7.2 3.8 13 5 11 165 2.7 0 2.8 2.6 12/20/2005 16:20:00 5.2 0.6 6.5 3.8 4.4 0.8 6.5 1.9 4.9 0.6 6.1 3.4 13 6 12 165 2.8 0 2.8 2.8 12/20/2005 16:30:00 5.5 0.6 6.8 3.8 4.4 1 6.1 1.9 5.4 0.6 6.8 3.4 11 6 12 165 2.9 0 3 2.8 12/20/2005 16:40:00 5.4 0.6 6.8 3.8 4.9 0.7 6.5 3 5.3 0.7 7.2 3.4 18 6 19 165 2.9 0 3 2.8 12/20/2005 16:50:00 5.6 0.6 7.2 4.2 5 0.8 6.8 2.3 5.4 0.6 6.8 4.2 15 5 8 165 3 0 3.3 2.8 12/20/2005 17:00:00 5.3 0.5 6.8 4.2 4.6 0.7 6.5 2.3 5.1 0.6 6.5 3.4 16 7 10 165 3 0 3.3 3 12/20/2005 17:10:00 5.8 0.8 7.6 3.8 5.2 0.9 7.2 2.3 5.7 0.8 8 4.2 17 6 19 165 3.2 0 3.5 3 12/20/2005 17:20:00 6.1 0.5 7.6 4.2 5.1 0.8 6.8 3 5.9 0.7 7.2 4.2 14 5 15 165 3.3 0 3.5 3.3 12/20/2005 17:30:00 5.3 0.8 6.8 3 4.2 1 6.8 1.9 5.2 0.8 6.8 3 11 8 23 165 3.3 0 3.5 3.3 12/20/2005 17:40:00 5.5 1.3 8.4 3 4.4 1.3 8 1.9 5.3 1.2 8.8 3 11 8 21 165 3.4 0 3.5 3.3 12/20/2005 17:50:00 5 0.6 6.5 3.4 4 0.8 5.7 1.9 4.9 0.7 6.5 3.4 13 6 5 165 3.4 0 3.5 3.3 12/20/2005 18:00:00 5.4 0.7 7.2 3.8 4.1 1 6.5 1.9 5.1 0.7 7.2 3.4 11 7 5 165 3.4 0 3.5 3.3 12/20/2005 18:10:00 5.5 0.8 7.6 2.6 4 0.9 6.1 1.9 5.2 0.8 7.2 3 9 8 8 165 3.5 0 3.5 3.5 12/20/2005 18:20:00 5.6 0.8 8 3.8 4.1 1 6.5 1.9 5.3 0.8 7.6 3.4 4 9 2 165 3.5 0 3.5 3.3 12/20/2005 18:30:00 6.6 1 9.1 3.4 5.5 1.1 8 3 6.2 1 8.8 2.6 11 8 2 165 3.5 0 3.5 3.3 12/20/2005 18:40:00 6.4 0.7 8.4 4.6 4.7 1 7.6 2.6 6.1 0.7 8 4.2 5 8 12 165 3.5 0 3.5 3.3 12/20/2005 18:50:00 5.8 0.9 8 3.4 4.4 1 8 1.9 5.4 0.7 8 3.8 1 11 6 165 3.3 0 3.5 3.3 12/20/2005 19:00:00 6.7 1.3 10.3 4.2 5.4 1.5 9.5 2.6 6.5 1.3 10.3 3.8 4 11 15 165 3.3 0 3.5 3.3 12/20/2005 19:10:00 7.4 0.9 9.5 5.7 5.9 1.4 8.8 2.6 7.4 1 9.9 5.3 9 7 11 165 3.2 0.1 3.5 3 12/20/2005 19:20:00 5.7 0.9 7.6 3.4 5 1 7.2 1.9 5.5 0.9 7.6 3.8 345 9 3 165 2.7 0 3.3 2.6 12/20/2005 19:30:00 5.1 0.6 6.8 3.4 5 0.6 6.8 3.8 5 0.5 6.5 3.8 332 8 339 165 2.6 0 2.8 2.6 12/20/2005 19:40:00 5.7 0.6 7.2 3.8 5.5 0.6 7.2 3.4 5.4 0.6 6.5 3.8 331 8 339 165 2.7 0 2.8 2.6 12/20/2005 19:50:00 4.5 0.5 6.5 3.4 4.3 0.6 6.1 2.3 4.3 0.5 5.7 3 337 7 336 165 2.7 0 2.8 2.6 12/20/2005 20:00:00 4.9 0.5 6.5 3.4 4.7 0.5 6.1 3 4.8 0.5 6.1 3 339 7 1 165 2.7 0 2.8 2.6 12/20/2005 20:10:00 5 0.5 6.1 3.8 4.8 0.5 6.1 3.4 4.9 0.4 6.1 3.8 340 7 346 165 2.7 0 3 2.8 12/20/2005 20:20:00 5.2 0.9 6.8 3.8 5.1 0.8 6.8 3.4 5.1 0.8 6.8 3.8 332 6 335 165 2.9 0 2.8 2.8 12/20/2005 20:30:00 5.8 0.6 7.6 4.2 5.7 0.6 7.2 4.2 5.7 0.7 7.2 3.4 333 7 319 165 2.9 0 3 2.8 12/20/2005 20:40:00 5.4 0.6 6.8 3.8 5.3 0.7 7.6 3 5.1 0.6 6.8 3.8 341 5 346 165 2.8 0 3 2.8 12/20/2005 20:50:00 5.8 0.6 7.2 4.6 5.7 0.7 7.6 3.4 5.5 0.7 7.2 4.2 341 7 350 165 2.9 0 3 2.8 12/20/2005 21:00:00 6.1 0.6 8 4.9 6 0.7 8.4 4.6 5.8 0.6 8 4.2 342 5 343 165 2.9 0 3 2.8 12/20/2005 21:10:00 4.5 0.8 6.1 3 4.4 0.8 6.5 3 4.4 0.7 6.5 3 336 8 347 165 2.9 0 3 2.8 12/20/2005 21:20:00 4.5 0.6 6.5 3 4.4 0.6 6.1 3 3.6 0.6 5.3 2.3 307 9 304 165 3 0 3.3 2.8 12/20/2005 21:30:00 5.4 0.7 7.2 3.8 5.3 0.7 6.8 3.4 4.5 0.9 6.8 2.3 310 10 310 165 3 0 3.3 2.8 12/20/2005 21:40:00 5.8 0.7 7.2 4.2 5.7 0.6 7.2 3.8 5.5 0.7 7.2 3.4 331 11 329 165 3 0 3 2.8 12/20/2005 21:50:00 4.4 1.1 7.2 1.9 4.3 1.2 7.2 2.3 4.3 1.1 7.2 2.3 335 12 336 165 3.1 0 3.3 2.8 12/20/2005 22:00:00 4 0.8 5.7 1.9 3.8 0.8 5.7 1.5 3.8 0.8 5.7 1.5 322 11 321 165 3 0 3.3 2.8 12/20/2005 22:10:00 3.7 0.7 5.3 1.9 3.6 0.7 5.3 1.5 3.4 0.6 4.9 2.3 320 12 330 165 2.9 0 3 2.8 12/20/2005 22:20:00 4 1.2 6.8 2.3 3.8 1.2 6.5 1.9 3.7 1.1 6.5 1.9 331 10 322 165 2.7 0 2.8 2.6 12/20/2005 22:30:00 5.7 0.9 7.6 3.8 5.7 1 8 3.4 5 1 7.6 3 333 11 344 165 2.7 0 2.8 2.8 12/20/2005 22:40:00 5.6 0.6 7.6 3.8 5.5 0.6 7.2 3.8 5.2 0.5 6.1 3.8 320 9 310 165 2.6 0.1 3 2.6 12/20/2005 22:50:00 6.2 0.7 8 4.6 6.1 0.7 7.6 4.6 5.8 0.8 8 3.8 316 7 319 165 2.7 0 2.8 2.6 12/20/2005 23:00:00 6.6 0.7 8 4.9 6.5 0.7 8 4.6 6.2 0.6 7.6 3.8 320 8 315 165 2.5 0.1 2.8 2.3 12/20/2005 23:10:00 7.6 0.7 9.5 5.7 7.5 0.8 9.5 5.3 6.4 1 9.5 4.2 310 6 303 165 2.4 0 2.6 2.3 12/20/2005 23:20:00 7.8 0.8 9.5 4.9 7.7 0.8 9.5 4.9 7.3 0.9 9.1 4.6 320 9 307 165 2.4 0 2.6 2.3 12/20/2005 23:30:00 8.2 1.2 11.8 4.9 8.1 1.2 11.5 4.9 7.4 1.1 10.3 4.6 318 9 315 165 2.5 0 2.8 2.3 12/20/2005 23:40:00 6 0.8 8.4 3.8 6 0.8 8 4.2 5.2 1 7.6 2.3 314 9 320 165 2.4 0 2.8 2.3 12/20/2005 23:50:00 5.9 0.8 7.6 3.8 5.8 0.8 7.6 3.4 5.1 1 7.2 3 319 11 329 165 2.4 0 2.6 2.6 12/21/2005 00:00:00 6.8 0.7 9.1 4.9 6.7 0.7 8.8 4.9 6.1 0.8 8 4.2 320 11 303 165 2.5 0 2.8 2.6 12/21/2005 00:10:00 6.8 0.8 9.9 4.9 6.7 0.8 9.9 4.9 6.4 1 9.1 4.2 319 12 300 165 2.7 0 2.8 2.6 12/21/2005 00:20:00 7.2 1.1 9.9 4.6 7.1 1.1 9.9 4.6 6 1 8.8 3 311 9 297 165 2.7 0 2.8 2.6 12/21/2005 00:30:00 9.1 1 11.5 6.5 9 1 11.5 6.1 7.1 1 11.1 4.9 304 6 300 165 2.7 0 2.8 2.6 12/21/2005 00:40:00 9.3 1.1 11.5 5.7 9.1 1 11.5 6.1 7.7 0.9 9.9 5.7 308 8 302 165 2.6 0.1 2.8 2.6 12/21/2005 00:50:00 8.3 0.8 10.3 5.7 8.2 0.8 11.1 6.1 6.8 0.9 9.1 4.6 309 6 302 165 2.4 0 2.6 2.6 12/21/2005 01:00:00 8.4 1 11.5 5.7 8.3 1 11.5 6.1 6.7 1 10.3 4.6 307 6 311 165 2.7 0 2.8 2.6 12/21/2005 01:10:00 7.3 1.2 10.7 4.9 7.3 1.2 10.7 4.9 6.8 1.3 10.3 3.4 323 13 321 165 2.6 0 2.8 2.6 12/21/2005 01:20:00 7.2 1 9.5 3.8 7 1 9.1 3.8 6.4 1.1 9.1 3.4 317 16 321 165 2.7 0 2.8 2.6 12/21/2005 01:30:00 7.7 1.2 11.8 5.3 7.6 1.2 12.2 4.6 7.4 1.3 11.8 4.9 326 12 348 165 2.7 0 2.8 2.6 12/21/2005 01:40:00 6.8 0.7 8.8 4.9 6.8 0.7 9.1 4.9 6.4 0.8 8.4 3.4 314 8 316 165 2.5 0 2.8 2.6 12/21/2005 01:50:00 7.2 0.8 9.1 5.7 7.1 0.8 9.1 5.7 6.5 0.8 9.1 4.2 312 6 308 165 2.3 0 2.6 2.3 12/21/2005 02:00:00 7.6 0.7 9.9 5.3 7.5 0.7 9.9 5.7 6.6 0.9 8.8 4.2 309 7 315 165 2.1 0 2.3 2.1 12/21/2005 02:10:00 7.3 1 9.1 4.6 7.2 1 9.5 4.2 6.5 1 8.8 4.2 311 8 307 165 2.1 0 2.3 1.8 12/21/2005 02:20:00 7.4 0.9 9.1 4.9 7.4 0.9 9.1 4.9 6.8 1 9.1 4.2 313 8 310 165 2 0 2.1 1.8 12/21/2005 02:30:00 7.6 0.8 9.5 5.3 7.5 0.7 9.1 5.3 6.3 0.9 8.4 4.2 307 10 299 165 1.9 0 2.1 1.8 12/21/2005 02:40:00 7.6 0.8 9.5 5.3 7.5 0.8 9.5 5.3 6.3 0.9 8.8 4.2 306 6 302 165 1.9 0 2.1 1.8 12/21/2005 02:50:00 7.8 0.8 9.5 5.7 7.7 0.8 9.5 5.7 6.2 0.9 9.5 4.2 304 6 290 165 1.9 0 2.1 1.8 12/21/2005 03:00:00 7.8 0.8 9.9 4.9 7.8 0.8 9.9 4.9 6.5 0.8 8.8 4.6 308 6 307 165 1.9 0 2.1 1.8 12/21/2005 03:10:00 7.9 0.8 10.3 6.1 7.9 0.8 9.9 6.1 7.2 1 9.5 4.2 312 8 299 165 1.9 0 2.3 1.8 12/21/2005 03:20:00 6.9 0.7 8.8 4.9 6.7 0.7 8.4 4.6 6.8 0.7 8.8 4.9 335 10 356 165 1.9 0 2.1 1.8 12/21/2005 03:30:00 7.3 1.1 10.7 5.3 6.3 1.3 10.3 3.4 7.1 1 9.9 4.2 351 12 344 165 2.1 0 2.3 1.8 12/21/2005 03:40:00 7.2 1.4 10.7 2.6 7 1.3 10.7 2.6 7.2 1.3 11.8 4.2 329 13 344 165 2.4 0.1 2.6 2.3 12/21/2005 03:50:00 5.6 0.9 8.4 3.8 5.5 0.9 8 2.6 5.5 0.8 7.6 3.4 329 13 344 165 2.4 0 2.6 2.3 12/21/2005 04:00:00 5.7 1.2 8.8 2.6 5.2 1.2 8.4 2.3 5.5 1.2 9.1 2.6 343 17 342 165 2.4 0 2.8 2.3 12/21/2005 04:10:00 6.8 1.7 11.1 3.4 6.5 1.9 11.5 3 6.7 1.5 11.1 3.4 342 14 344 165 2.6 0 2.8 2.6 12/21/2005 04:20:00 6.2 1.4 9.9 3.4 5.7 1.4 9.5 2.6 5.9 1.3 8.8 1.9 341 15 6 165 2.6 0 2.8 2.6 12/21/2005 04:30:00 4 1.5 8.4 0.7 3.6 1.5 8 0.7 3.8 1.3 7.2 1.5 337 20 359 165 2.5 0 2.8 2.3 12/21/2005 04:40:00 3.6 1.9 6.8 0.4 3.6 1.9 7.2 0.4 3 1.6 7.2 0.4 316 22 337 165 2.4 0 2.6 2.3 12/21/2005 04:50:00 3.9 1 6.1 1.1 3.9 1 6.1 1.1 2.9 1 6.1 0.4 296 17 292 165 2.3 0 2.6 2.1 12/21/2005 05:00:00 4.7 1.1 7.6 2.6 4.6 1.1 8 2.6 3.8 1 6.8 1.1 296 14 288 165 2.1 0 2.3 2.1 12/21/2005 05:10:00 6.2 1.4 9.9 3.8 6.1 1.4 9.9 3.4 5.1 1.5 10.3 2.3 310 12 322 165 2.1 0 2.3 1.8 12/21/2005 05:20:00 7 1.2 10.7 3.8 7 1.2 10.7 3.4 5.6 1.2 9.1 2.3 307 9 302 165 2.3 0 2.6 2.3 12/21/2005 05:30:00 6.1 1.2 9.5 3.4 6.1 1.2 9.5 2.6 4.4 1.3 8 1.1 303 14 289 165 2.2 0 2.6 2.1 12/21/2005 05:40:00 5.2 1.7 10.3 1.5 5.2 1.7 10.7 0.7 3.8 1.5 8.4 0.4 312 17 306 165 2.2 0 2.3 2.1 12/21/2005 05:50:00 4.8 1.3 8 1.1 4.7 1.4 8.4 1.1 3.8 1.4 8.4 0.4 308 17 301 165 2.4 0 2.6 2.3 12/21/2005 06:00:00 6.7 2 14.9 0.7 6.6 2 15.3 0.7 5.4 2 10.3 0.4 310 17 303 165 2.4 0 2.6 2.3 12/21/2005 06:10:00 5.3 1.7 10.7 1.1 5.3 1.7 10.3 0.7 4 1.5 7.6 0.4 301 20 291 165 2.4 0 2.8 2.3 12/21/2005 06:20:00 6 1.9 11.1 2.3 6 1.9 11.1 2.3 4.9 1.8 10.7 0.7 311 19 313 165 2.4 0 2.8 2.3 12/21/2005 06:30:00 7.6 1.5 11.8 4.2 7.6 1.4 11.8 4.2 6.8 1.7 11.8 3.4 311 12 310 165 2.7 0 2.8 2.6 12/21/2005 06:40:00 8.2 1.3 13 5.7 8.2 1.3 12.6 5.3 6.6 1.3 11.1 3.8 305 8 301 165 2.4 0 2.8 2.3 12/21/2005 06:50:00 9.9 1.2 13.7 6.8 9.9 1.2 13.3 6.5 8.3 1.4 13 5.3 311 13 316 165 2.1 0 2.3 2.1 12/21/2005 07:00:00 7.7 1.9 11.8 3.4 7.6 1.9 12.2 3 6.8 1.6 11.5 2.6 310 15 305 165 2.4 0 2.6 2.3 12/21/2005 07:10:00 5.7 0.9 8 3.4 5.6 0.9 7.6 3.4 5.3 1 7.2 1.9 320 18 330 165 2.3 0 2.6 2.3 12/21/2005 07:20:00 6.6 1.1 9.5 3.8 6.5 1.1 9.9 3.8 5.8 1.2 10.3 2.6 311 12 300 165 2.4 0 2.6 2.3 12/21/2005 07:30:00 6.8 1.2 10.7 3.4 6.8 1.2 11.1 3.4 6 1.1 10.7 3.4 311 16 296 165 2.3 0 2.6 2.3 12/21/2005 07:40:00 7 1 9.1 2.6 6.9 1 9.1 2.3 5.7 0.9 8 1.9 303 10 301 165 2.3 0 2.6 2.3 12/21/2005 07:50:00 6.7 1 9.5 4.2 6.7 1 9.1 4.2 5.7 0.9 9.5 3.4 298 11 292 165 2.4 0 2.6 2.3 12/21/2005 08:00:00 8.7 1 12.2 5.3 8.6 1 12.2 5.3 7.1 1.2 10.7 4.6 304 11 285 165 2.3 0 2.6 2.1 12/21/2005 08:10:00 9.2 1.3 11.8 5.7 9.2 1.2 11.5 5.3 7.4 1.2 11.1 4.6 301 9 274 165 2.3 0 2.6 2.3 12/21/2005 08:20:00 7.7 1 9.9 4.9 7.6 1 10.3 4.9 6.2 1 8.8 3.8 302 8 304 165 2.3 0 2.6 2.3 12/21/2005 08:30:00 8.3 1 11.8 5.7 8.2 1 11.8 5.7 6.5 1 9.9 4.2 302 9 292 165 2.2 0 2.3 2.1 12/21/2005 08:40:00 8.6 0.9 11.8 5.7 8.5 0.8 11.1 6.1 6.5 0.9 9.9 4.6 299 6 307 165 2.1 0 2.3 2.1 12/21/2005 08:50:00 9.6 1.2 14.5 6.5 9.6 1.2 13.7 6.1 7.5 1.3 13 4.2 297 6 285 165 2.1 0 2.3 1.8 12/21/2005 09:00:00 9.7 1 11.8 7.2 9.6 1 11.8 7.2 7.4 1 10.7 4.9 299 7 311 165 1.9 0 2.1 1.8 12/21/2005 09:10:00 9.6 1 12.2 7.2 9.5 1 12.2 7.2 7.2 1 10.3 4.9 298 5 299 165 1.9 0 1.8 1.8 12/21/2005 09:20:00 9.2 1.1 11.5 4.9 9.2 1.1 11.8 4.2 7 1.1 11.1 4.2 299 6 298 165 2 0 2.1 1.8 12/21/2005 09:30:00 9 1.2 12.2 4.9 8.9 1.2 11.8 5.3 7.4 1.3 11.8 4.6 301 8 305 165 2 0 2.3 1.8 12/21/2005 09:40:00 8.6 1.1 12.6 6.1 8.5 1.1 12.6 5.7 7.3 1.2 10.7 4.6 310 12 295 165 2.1 0.1 2.3 1.8 12/21/2005 09:50:00 7.1 1.2 11.1 4.2 7 1.2 11.1 3.8 6.4 1.3 10.7 3 316 12 313 165 2.1 0 2.3 1.8 12/21/2005 10:00:00 6.9 0.9 8.8 4.6 6.8 0.9 8.4 4.2 6.1 1.1 8.8 3.4 310 12 291 165 2.3 0 2.6 2.1 12/21/2005 10:10:00 8.1 1.3 12.2 5.3 8.1 1.3 12.6 4.9 6.6 1.2 11.1 3.4 304 8 291 165 2.1 0 2.3 1.8 12/21/2005 10:20:00 7.9 1.1 10.7 5.3 7.8 1.1 10.7 4.9 6.2 1 9.9 4.2 302 9 297 165 2 0 2.3 1.8 12/21/2005 10:30:00 8.9 1.1 12.2 5.7 8.8 1 12.2 6.1 6.8 1.2 11.5 4.2 300 7 298 165 2.1 0 2.3 1.8 12/21/2005 10:40:00 9.5 0.9 11.8 6.5 9.4 0.8 11.5 6.8 7.3 1 10.3 4.9 298 6 294 165 2.1 0 2.3 1.8 12/21/2005 10:50:00 9.5 0.9 12.6 7.6 9.4 0.9 12.2 7.2 7.2 1.1 10.3 4.9 298 6 301 165 2 0 2.3 1.8 12/21/2005 11:00:00 9.1 1.3 14.5 5.3 9 1.3 14.9 4.9 7.5 1.3 11.8 4.6 307 9 300 165 2.1 0 2.3 1.8 12/21/2005 11:10:00 8.2 1.9 14.1 3.8 8.2 1.8 13.7 3.8 7.1 1.7 14.5 3.8 308 13 301 165 2.4 0 2.6 2.1 12/21/2005 11:20:00 8 1.2 11.5 4.9 8 1.2 11.5 4.6 6.7 1.3 10.3 4.2 305 11 324 165 2.3 0 2.6 2.3 12/21/2005 11:30:00 8.1 1.1 11.8 4.9 8 1 12.2 4.9 6.6 1 9.9 4.2 305 9 286 165 2.3 0 2.6 2.3 12/21/2005 11:40:00 9 1 12.6 6.1 9 1 12.6 6.1 7.2 1.3 11.5 4.6 301 9 288 165 2.3 0 2.6 2.3 12/21/2005 11:50:00 8.9 1 11.5 6.8 8.8 1 12.2 6.1 7.2 1.2 10.7 4.6 305 7 316 165 2.3 0 2.6 2.3 12/21/2005 12:00:00 8.9 1 11.8 6.1 8.9 1 11.5 6.1 7.4 1.2 10.7 4.6 307 7 302 165 2.4 0 2.6 2.3 12/21/2005 12:10:00 9.6 0.8 12.2 7.6 9.5 0.8 11.8 7.2 7.9 1 11.1 4.9 308 6 305 165 2.4 0 2.6 2.3 12/21/2005 12:20:00 9.6 0.7 12.6 8 9.6 0.7 12.6 8 8.3 0.9 11.5 6.1 309 6 298 165 2.4 0 2.6 2.3 12/21/2005 12:30:00 9.3 0.8 11.5 7.2 9.2 0.7 11.1 7.6 7.9 1.1 10.7 5.7 309 6 312 165 2.4 0 2.6 2.3 12/21/2005 12:40:00 8.9 1 11.5 6.1 8.8 1 11.1 6.1 7.6 1.2 11.5 4.6 309 7 296 165 2.4 0 2.6 2.3 12/21/2005 12:50:00 7.7 0.8 10.7 5.7 7.6 0.8 10.3 5.7 6.4 0.8 8.8 4.2 307 7 301 165 2.5 0 2.8 2.6 12/21/2005 13:00:00 8.2 1.2 11.1 5.3 8 1.2 11.1 4.6 6.2 1.1 9.5 3.8 300 7 300 165 2.6 0.1 2.8 2.6 12/21/2005 13:10:00 8.5 1 11.5 6.8 8.5 1 11.5 6.8 6.6 0.8 8.4 4.6 303 7 301 165 2.4 0 2.8 2.3 12/21/2005 13:20:00 7.8 0.8 9.5 5.3 7.7 0.8 9.5 5.7 7.1 1 9.5 4.2 313 6 314 165 2.4 0 2.6 2.3 12/21/2005 13:30:00 8.6 0.7 10.7 6.5 8.5 0.8 10.3 6.5 8 1 10.3 5.7 314 6 321 165 2.3 0 2.6 2.3 12/21/2005 13:40:00 8.6 0.9 11.5 6.8 8.5 0.8 11.5 6.8 7.9 1 10.7 4.9 313 5 309 165 2.3 0 2.6 2.3 12/21/2005 13:50:00 8 0.8 9.9 6.5 7.9 0.8 9.5 6.1 7.8 0.9 9.5 5.3 319 5 314 165 2.4 0 2.6 2.3 12/21/2005 14:00:00 7.9 0.7 9.5 6.1 7.7 0.7 9.1 5.7 7.6 0.7 9.1 5.3 317 5 311 165 2.4 0 2.6 2.3 12/21/2005 14:10:00 7 0.6 8.4 5.3 6.9 0.6 8.4 5.3 6.8 0.6 8.8 5.3 317 5 310 165 2.4 0 2.6 2.3 12/21/2005 14:20:00 7.5 0.6 9.1 5.7 7.4 0.6 8.8 5.7 6.8 0.8 8.4 4.6 312 5 314 165 2.4 0 2.6 2.3 12/21/2005 14:30:00 6.8 0.8 8.8 4.9 6.8 0.8 8.8 4.9 5.8 1 8.4 3.8 308 6 310 165 2.5 0 2.6 2.6 12/21/2005 14:40:00 8 0.6 9.5 6.5 7.9 0.6 9.1 6.1 6.9 0.8 9.1 4.2 309 4 305 165 2.6 0 2.8 2.6 12/21/2005 14:50:00 8.2 0.7 10.3 6.1 8.1 0.7 10.3 6.1 7 0.9 9.1 3.8 309 5 309 165 2.7 0 2.8 2.6 12/21/2005 15:00:00 8.6 0.7 9.9 6.1 8.4 0.7 9.9 5.7 7.7 0.9 9.9 5.3 310 6 307 165 2.7 0 2.8 2.6 12/21/2005 15:10:00 9.2 0.8 11.5 7.2 9 0.8 11.1 7.2 9 0.8 11.5 7.2 320 5 317 165 2.6 0 2.8 2.6 12/21/2005 15:20:00 9 0.9 11.5 7.2 8.8 0.8 11.1 6.8 8.4 1 11.1 6.1 317 8 305 165 2.5 0 2.8 2.6 12/21/2005 15:30:00 10.4 1.1 13.3 8 10.3 1.1 13.3 7.6 9.7 1.3 13.3 6.5 315 7 321 165 2.8 0 2.8 2.6 12/21/2005 15:40:00 11.4 0.9 13.3 8 11.3 0.9 13.3 8 11.1 1 13.7 8 317 5 317 165 2.7 0 3 2.6 12/21/2005 15:50:00 10.4 0.8 12.2 8.4 10.3 0.8 12.2 8 9.9 1 12.2 6.8 315 5 319 165 2.7 0 2.8 2.6 12/21/2005 16:00:00 10.2 0.7 11.8 8 10.1 0.7 11.5 8 9.8 1 11.8 6.5 314 5 308 165 2.7 0 2.8 2.6 12/21/2005 16:10:00 9.8 0.7 11.5 8 9.7 0.7 11.5 8 9.2 0.8 11.1 6.8 315 4 317 165 2.5 0 2.8 2.6 12/21/2005 16:20:00 7.7 0.7 9.5 6.1 7.6 0.8 9.9 6.1 7.3 0.8 9.9 4.9 317 7 310 165 2.4 0 2.6 2.3 12/21/2005 16:30:00 6.9 0.7 9.1 4.9 6.7 0.7 9.5 4.9 6.7 0.7 9.1 4.6 318 7 319 165 2.3 0 2.6 2.3 12/21/2005 16:40:00 7.1 0.8 9.1 5.3 6.9 0.8 8.8 5.3 6.7 0.8 9.1 5.3 316 6 313 165 2.3 0 2.3 2.3 12/21/2005 16:50:00 7.3 0.7 9.1 5.7 7.1 0.7 9.1 5.7 7 0.7 8.8 5.3 319 6 314 165 2.3 0 2.6 2.3 12/21/2005 17:00:00 6.6 0.7 8.8 4.9 6.5 0.7 8.8 4.6 6.4 0.7 8.4 4.2 320 8 310 165 2.3 0 2.6 2.3 12/21/2005 17:10:00 7.4 0.6 9.1 4.9 7.3 0.6 9.1 4.9 7.2 0.6 8.8 5.3 321 6 314 165 2.2 0 2.3 2.1 12/21/2005 17:20:00 6.7 0.6 8.4 4.9 6.5 0.6 8 4.9 6.5 0.6 7.6 4.9 322 7 321 165 2.1 0 2.3 1.8 12/21/2005 17:30:00 7.8 0.7 9.9 6.1 7.7 0.7 9.5 6.1 7.2 0.8 9.1 4.9 314 5 310 165 2.1 0 2.3 1.8 12/21/2005 17:40:00 5.9 1 8.4 3.4 5.8 1 8 3.8 5.5 1 7.6 3.4 314 8 305 165 2 0 2.3 1.8 12/21/2005 17:50:00 5.1 0.5 6.8 3.8 5.1 0.5 6.5 3.4 4.5 0.6 6.1 3 308 6 310 165 1.9 0 2.1 1.8 12/21/2005 18:00:00 5 0.7 7.2 3.4 5 0.7 7.2 3.4 4.4 0.8 6.8 2.6 308 6 302 165 1.9 0 2.1 1.8 12/21/2005 18:10:00 5.5 0.6 7.2 3.8 5.5 0.7 7.2 3.8 4.8 0.7 6.8 3.4 309 6 307 165 1.9 0 2.1 1.8 12/21/2005 18:20:00 6.2 0.7 8.8 4.6 6.2 0.7 8.8 4.6 5.7 0.8 7.6 3.8 312 8 314 165 1.8 0 1.8 1.6 12/21/2005 18:30:00 6.1 1 8.4 3.8 6 0.9 8.4 3.4 5.1 0.9 8 2.6 309 8 305 165 1.8 0 1.8 1.6 12/21/2005 18:40:00 6.6 1.2 9.1 4.6 6.5 1.1 9.5 4.6 5.4 1 8 3 306 7 300 165 1.7 0 1.8 1.6 12/21/2005 18:50:00 8.1 0.9 10.7 6.1 8 0.9 10.3 6.5 6.6 0.8 8.8 4.6 306 5 296 165 1.8 0 1.8 1.6 12/21/2005 19:00:00 7.2 0.6 8.8 5.3 7.2 0.6 8.8 5.7 6.4 0.7 8.8 4.2 309 6 310 165 1.8 0 1.8 1.6 12/21/2005 19:10:00 7.9 0.9 9.5 5.7 7.8 0.9 9.5 5.7 7.1 0.9 8.8 4.6 311 6 307 165 1.8 0 1.8 1.6 12/21/2005 19:20:00 8.7 0.8 10.7 5.7 8.6 0.8 10.7 5.7 7 0.9 9.1 4.2 305 6 298 165 1.9 0 2.1 1.6 12/21/2005 19:30:00 9.4 0.7 11.5 7.2 9.3 0.6 11.5 7.6 7.1 0.9 9.1 4.6 301 4 295 165 1.9 0 2.3 1.8 12/21/2005 19:40:00 7.6 1 9.5 5.3 7.6 1 9.9 5.3 6.1 1 8.4 2.6 302 7 293 165 1.8 0 1.8 1.8 12/21/2005 19:50:00 7.1 1 9.5 4.6 7.1 0.9 9.1 4.9 5.9 1.2 9.1 3 305 9 317 165 1.8 0 1.8 1.6 12/21/2005 20:00:00 8.2 0.9 10.7 6.1 8.2 0.9 11.1 6.1 6.6 1 9.9 4.2 305 5 310 165 1.9 0 2.1 1.8 12/21/2005 20:10:00 8.6 0.8 10.7 6.1 8.6 0.8 10.7 6.1 6.5 0.9 8.8 4.6 304 4 309 165 2.1 0 2.3 1.8 12/21/2005 20:20:00 8.6 0.6 9.9 6.5 8.6 0.6 9.9 6.5 6.3 0.8 8.8 4.2 300 5 307 165 2.2 0 2.6 1.8 12/21/2005 20:30:00 9 0.5 10.3 6.8 9 0.6 10.3 6.8 6.4 0.7 9.1 4.9 296 3 296 165 2.2 0 2.3 1.8 12/21/2005 20:40:00 8.2 0.5 9.1 6.8 8.2 0.5 9.1 6.5 6.5 0.7 8.4 4.6 293 3 298 165 2.1 0 2.3 1.8 12/21/2005 20:50:00 7.2 0.4 8.4 6.1 7.3 0.4 8.8 6.1 6.8 0.7 8.4 4.9 287 3 291 165 2.2 0 2.3 2.1 12/21/2005 21:00:00 6.1 0.4 7.2 5.3 6.2 0.4 7.2 5.3 5.6 0.6 7.2 3.4 287 3 287 165 2 0.1 2.3 1.8 12/21/2005 21:10:00 5.2 0.5 6.1 3.4 5.6 0.3 6.5 4.2 5.4 0.4 6.5 4.2 274 5 282 165 1.9 0 2.1 1.8 12/21/2005 21:20:00 3.7 0.6 5.7 2.3 5.4 0.3 6.1 4.6 5 0.4 5.7 3.8 267 2 271 165 1.9 0 2.1 1.8 12/21/2005 21:30:00 2.8 0.5 4.2 1.5 4.7 0.4 5.3 3.4 4 0.5 5.3 3 260 3 261 165 1.9 0 2.1 1.8 12/21/2005 21:40:00 2.9 0.5 4.2 1.9 4 0.4 4.6 3 3.8 0.3 4.6 3 253 7 252 165 2 0 2.3 1.8 12/21/2005 21:50:00 2.1 0.8 3.4 0.4 2 0.8 3.4 0.4 2.3 0.7 3.4 0.7 232 7 229 165 2.1 0 2.3 1.8 12/21/2005 22:00:00 1.3 0.4 2.3 0.4 1.4 0.4 2.6 0.4 1.8 0.4 2.6 0.7 248 9 261 165 2.4 0 2.6 2.3 12/21/2005 22:10:00 2.1 0.5 3 1.1 2 0.5 3 0.7 2 0.5 3 0.7 226 8 220 165 2.4 0 2.8 2.3 12/21/2005 22:20:00 2.5 0.3 3 1.5 2.3 0.3 3 1.1 2.5 0.4 3 1.5 208 5 206 165 2.4 0 2.6 2.3 12/21/2005 22:30:00 0.8 0.5 2.3 0.4 0.5 0.3 1.9 0.4 0.6 0.4 1.9 0.4 213 10 207 165 2.4 0 2.6 2.3 12/21/2005 22:40:00 0.4 0.1 0.7 0.4 0.4 0 0.7 0.4 0.4 0.1 1.1 0.4 238 14 256 165 2.6 0 2.8 2.6 12/21/2005 22:50:00 0.7 0.5 1.5 0.4 0.4 0.2 1.1 0.4 0.8 0.4 1.9 0.4 206 4 208 165 2.6 0 2.8 2.6 12/21/2005 23:00:00 0.6 0.4 1.9 0.4 0.4 0 0.4 0.4 0.6 0.4 1.9 0.4 207 0 207 165 2.5 0 2.8 2.6 12/21/2005 23:10:00 1.3 0.5 2.3 0.4 0.8 0.5 1.9 0.4 1.4 0.5 2.3 0.4 191 5 194 165 2.6 0 2.8 2.6 12/21/2005 23:20:00 1.3 0.4 1.9 0.4 0.8 0.5 1.9 0.4 1.3 0.4 1.9 0.7 184 2 182 165 2.4 0 2.6 2.6 12/21/2005 23:30:00 1 0.5 1.9 0.4 0.7 0.4 1.5 0.4 0.9 0.5 1.5 0.4 186 1 187 165 2.4 0 2.8 2.3 12/21/2005 23:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 185 0 165 165 2.3 0 2.6 2.3 12/21/2005 23:50:00 0.4 0.1 0.7 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 186 6 185 165 2.5 0 2.6 2.6 12/22/2005 00:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.7 0.4 216 2 165 165 2.7 0 2.8 2.6 12/22/2005 00:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.7 0.4 182 8 165 165 2.1 0.2 2.8 1.8 12/22/2005 00:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 180 0 165 165 1.8 0 1.8 1.6 12/22/2005 00:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 183 0 165 165 1.7 0 1.8 1.6 12/22/2005 00:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.7 0.4 212 39 165 165 1.7 0 1.8 1.6 12/22/2005 00:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 265 0 165 165 1.7 0 1.8 1.6 12/22/2005 01:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.7 0.3 1.5 0.4 265 0 165 165 1.7 0 1.8 1.6 12/22/2005 01:10:00 0.7 0.3 1.5 0.4 0.4 0.2 1.1 0.4 1.2 0.3 1.9 0.4 332 22 349 165 1.9 0 2.1 1.8 12/22/2005 01:20:00 1.5 0.2 1.9 1.1 0.9 0.2 1.5 0.4 1.9 0.2 2.3 1.5 350 3 349 165 2 0 2.1 1.8 12/22/2005 01:30:00 2.3 0.3 2.6 1.5 1 0.3 1.5 0.4 2.5 0.2 3 1.9 357 0 356 165 1.8 0 2.1 1.6 12/22/2005 01:40:00 3 0.3 3.4 2.3 1.8 0.6 3 0.7 3.3 0.3 4.2 2.6 4 6 8 165 1.7 0 1.8 1.6 12/22/2005 01:50:00 3.4 0.3 4.2 2.6 2.4 0.7 3.8 0.7 3.9 0.3 4.6 3 11 5 17 165 1.8 0 1.8 1.8 12/22/2005 02:00:00 2.8 0.6 3.8 1.5 2.4 0.7 3.8 0.7 3.4 0.6 4.6 1.9 18 6 22 165 1.9 0 2.1 1.8 12/22/2005 02:10:00 1.3 0.4 2.3 0.4 0.7 0.4 1.9 0.4 1.7 0.4 2.6 0.7 12 6 23 165 2.1 0 2.3 1.8 12/22/2005 02:20:00 0.6 0.3 1.5 0.4 0.4 0.1 1.1 0.4 0.9 0.3 1.5 0.4 356 6 357 165 2.1 0 2.3 2.1 12/22/2005 02:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.7 0.4 329 35 165 165 2 0 2.3 1.8 12/22/2005 02:40:00 0.4 0.1 0.7 0.4 0.4 0 0.4 0.4 0.4 0.1 0.7 0.4 226 18 219 165 1.9 0 2.1 1.8 12/22/2005 02:50:00 0.8 0.4 1.5 0.4 0.6 0.3 1.5 0.4 1 0.4 1.9 0.4 171 18 174 165 2 0 2.3 1.8 12/22/2005 03:00:00 0.5 0.2 1.5 0.4 0.4 0.1 1.1 0.4 0.5 0.3 1.5 0.4 176 26 186 165 2.1 0 2.3 1.8 12/22/2005 03:10:00 1.2 0.6 2.6 0.4 1.4 0.7 2.6 0.4 1 0.6 2.6 0.4 250 17 282 165 1.9 0.1 2.3 1.6 12/22/2005 03:20:00 2.7 0.8 3.8 0.7 3 1 4.6 0.7 3.5 0.8 4.6 1.5 250 5 249 165 1.5 0 1.8 1.4 12/22/2005 03:30:00 1.9 0.7 3.8 0.4 2.2 0.8 3.8 0.7 3 0.5 4.2 1.9 254 9 250 165 1.7 0 1.8 1.6 12/22/2005 03:40:00 1.7 0.6 3 0.4 1.7 0.5 3 0.4 2.8 0.4 3.8 1.9 244 9 236 165 1.9 0 2.1 1.6 12/22/2005 03:50:00 1.8 0.6 3 0.4 1.6 0.6 3 0.4 2.2 0.6 3.8 0.7 311 30 351 165 1.8 0.3 2.3 1.4 12/22/2005 04:00:00 1.5 0.4 2.3 0.4 1.5 0.3 2.3 0.7 1.6 0.3 2.3 0.7 271 18 276 165 1.7 0.2 1.8 1.4 12/22/2005 04:10:00 1.5 0.4 2.6 0.7 1.5 0.4 2.6 0.7 1.7 0.3 2.6 1.1 261 11 271 165 2.2 0.2 2.6 1.8 12/22/2005 04:20:00 1.8 0.5 2.6 0.7 1.7 0.5 2.6 0.7 2 0.5 3 1.1 272 2 273 165 2.4 0 2.6 2.3 12/22/2005 04:30:00 1.3 0.4 2.3 0.7 1.1 0.4 2.3 0.4 1.5 0.3 2.6 0.7 282 3 279 165 2.4 0 2.6 2.3 12/22/2005 04:40:00 2.3 0.2 2.6 1.9 2.2 0.2 2.6 1.9 2.1 0.3 2.6 1.5 291 4 282 165 2 0.2 2.6 1.8 12/22/2005 04:50:00 1.9 0.4 2.6 1.1 1.8 0.4 2.6 1.1 1.4 0.6 2.6 0.4 289 4 290 165 1.9 0 1.8 1.6 12/22/2005 05:00:00 1 0.4 1.9 0.4 0.8 0.4 1.9 0.4 0.6 0.3 1.5 0.4 292 4 299 165 1.9 0 1.8 1.8 12/22/2005 05:10:00 0.7 0.2 1.5 0.4 0.4 0.2 1.1 0.4 0.6 0.3 1.1 0.4 289 0 290 165 1.9 0 2.1 1.6 12/22/2005 05:20:00 0.4 0.1 0.7 0.4 0.4 0 0.4 0.4 0.4 0 0.7 0.4 276 26 290 165 1.4 0.1 1.8 1.1 12/22/2005 05:30:00 0.5 0.3 1.5 0.4 0.4 0.2 1.5 0.4 1 0.5 1.9 0.4 239 10 240 165 1.4 0 1.6 1.1 12/22/2005 05:40:00 0.9 0.3 1.5 0.4 0.7 0.3 1.5 0.4 1.1 0.4 2.3 0.4 260 22 232 165 1.3 0.1 1.6 1.1 12/22/2005 05:50:00 0.4 0.1 1.1 0.4 0.4 0.1 1.1 0.4 0.4 0.2 1.5 0.4 288 1 284 165 1.6 0 1.8 1.4 12/22/2005 06:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 277 12 165 165 1.4 0 1.6 1.4 12/22/2005 06:10:00 0.7 0.4 1.5 0.4 0.6 0.4 1.5 0.4 0.8 0.5 1.9 0.4 244 20 224 165 1.4 0 1.6 1.4 12/22/2005 06:20:00 0.4 0.2 1.1 0.4 0.4 0.1 1.1 0.4 0.5 0.2 1.1 0.4 224 0 224 165 1.4 0 1.6 1.4 12/22/2005 06:30:00 0.4 0.1 0.7 0.4 0.4 0 0.4 0.4 0.4 0.1 0.7 0.4 238 13 224 165 1.5 0 1.8 1.4 12/22/2005 06:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 251 0 165 165 1.5 0.2 1.8 0.9 12/22/2005 06:50:00 0.9 0.3 1.5 0.4 0.7 0.3 1.5 0.4 1.1 0.4 1.9 0.4 186 21 181 165 1.1 0.1 1.4 0.9 12/22/2005 07:00:00 1.5 0.6 2.3 0.4 1.4 0.6 2.3 0.4 1.6 0.7 2.6 0.4 188 12 200 165 1.1 0 1.4 0.9 12/22/2005 07:10:00 1.9 0.3 2.6 1.1 1.8 0.3 2.3 1.1 2.1 0.2 2.6 1.5 190 3 185 165 1.1 0 1.4 0.9 12/22/2005 07:20:00 1 0.4 1.5 0.4 0.8 0.4 1.5 0.4 1.4 0.3 1.9 0.4 187 7 195 165 1 0 1.4 0.9 12/22/2005 07:30:00 1.3 0.5 2.3 0.4 1.2 0.6 2.3 0.4 1.7 0.5 2.6 0.7 181 7 178 165 1.1 0 1.4 0.9 12/22/2005 07:40:00 0.6 0.4 1.9 0.4 0.5 0.3 1.5 0.4 0.9 0.4 1.9 0.4 174 1 172 165 1 0 1.4 0.9 12/22/2005 07:50:00 1.1 0.6 2.3 0.4 1 0.6 2.3 0.4 1.5 0.7 2.6 0.4 171 3 168 165 1.1 0 1.4 0.9 12/22/2005 08:00:00 1.3 0.6 2.3 0.4 1.1 0.6 2.3 0.4 1.5 0.7 2.3 0.4 168 3 167 165 1 0 1.4 0.9 12/22/2005 08:10:00 0.4 0.2 1.1 0.4 0.4 0 0.4 0.4 0.4 0.2 1.1 0.4 162 4 156 165 0.9 0 1.1 0.9 12/22/2005 08:20:00 0.9 0.6 2.3 0.4 0.8 0.6 2.3 0.4 0.8 0.5 2.3 0.4 118 18 114 165 1.2 0.1 1.4 0.9 12/22/2005 08:30:00 0.5 0.3 1.5 0.4 0.5 0.3 1.5 0.4 0.6 0.4 1.9 0.4 123 17 104 165 1.4 0 1.6 1.4 12/22/2005 08:40:00 0.5 0.3 1.5 0.4 0.4 0.3 1.5 0.4 0.5 0.2 1.5 0.4 43 18 63 165 0.9 0.1 1.4 0.7 12/22/2005 08:50:00 0.9 0.4 1.5 0.4 0.8 0.3 1.5 0.4 1 0.4 1.9 0.4 46 13 52 165 0.8 0 0.9 0.7 12/22/2005 09:00:00 1 0.4 1.9 0.4 0.8 0.4 1.9 0.4 1.2 0.3 1.9 0.7 37 7 41 165 0.8 0 0.9 0.9 12/22/2005 09:10:00 1 0.3 1.5 0.4 0.5 0.2 1.1 0.4 1.1 0.2 1.5 0.7 20 4 22 165 0.8 0 0.9 0.9 12/22/2005 09:20:00 0.4 0.1 0.7 0.4 0.4 0 0.7 0.4 0.4 0.1 1.1 0.4 62 24 102 165 0.9 0 1.1 0.9 12/22/2005 09:30:00 0.6 0.3 1.5 0.4 0.5 0.2 1.5 0.4 0.7 0.4 1.5 0.4 108 10 101 165 1.2 0.2 1.6 0.9 12/22/2005 09:40:00 0.9 0.4 1.9 0.4 0.9 0.4 1.9 0.4 0.7 0.5 1.9 0.4 122 0 122 165 1.5 0 1.6 1.4 12/22/2005 09:50:00 0.7 0.4 1.9 0.4 0.8 0.4 1.9 0.4 0.6 0.3 1.5 0.4 114 4 108 165 1.7 0 1.6 1.6 12/22/2005 10:00:00 0.4 0.2 1.5 0.4 0.4 0.1 1.1 0.4 0.4 0.2 1.1 0.4 177 58 151 165 1.7 0 1.8 1.6 12/22/2005 10:10:00 0.4 0.3 2.3 0.4 0.5 0.4 2.3 0.4 0.4 0.2 1.9 0.4 44 45 96 165 1.6 0 1.8 1.6 12/22/2005 10:20:00 0.8 0.5 2.3 0.4 0.8 0.5 2.3 0.4 1.1 0.4 2.3 0.4 105 7 96 165 1.9 0.1 2.1 1.6 12/22/2005 10:30:00 1.1 0.5 2.3 0.4 1.1 0.5 2.3 0.4 1.4 0.6 2.6 0.4 107 6 110 165 2 0 2.1 1.8 12/22/2005 10:40:00 0.4 0.2 1.9 0.4 0.4 0.2 1.5 0.4 0.7 0.4 1.9 0.4 102 6 101 165 2 0 2.3 1.8 12/22/2005 10:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0.1 1.1 0.4 112 3 165 165 2 0 2.3 1.8 12/22/2005 11:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 117 6 165 165 1.9 0 2.1 1.8 12/22/2005 11:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0.2 1.1 0.4 127 0 165 165 2 0 2.3 1.8 12/22/2005 11:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0.1 0.7 0.4 128 0 165 165 2.1 0 2.3 2.1 12/22/2005 11:30:00 0.5 0.3 1.9 0.4 0.5 0.3 1.9 0.4 0.6 0.4 1.9 0.4 113 13 116 165 2.3 0 2.6 2.1 12/22/2005 11:40:00 0.9 0.6 2.3 0.4 0.9 0.6 2.3 0.4 1.2 0.5 2.3 0.4 117 13 93 165 2.4 0 2.6 2.3 12/22/2005 11:50:00 0.8 0.5 1.9 0.4 0.7 0.4 1.9 0.4 0.9 0.5 1.9 0.4 86 17 87 165 2.4 0 2.8 2.6 12/22/2005 12:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0.1 1.1 0.4 104 29 165 165 2.5 0 2.6 2.6 12/22/2005 12:10:00 0.4 0.2 1.5 0.4 0.4 0.1 1.1 0.4 0.4 0.2 1.9 0.4 151 0 151 165 2.6 0 2.8 2.6 12/22/2005 12:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 151 0 165 165 2.9 0.1 3 2.6 12/22/2005 12:30:00 0.4 0.1 1.1 0.4 0.4 0.1 0.7 0.4 0.4 0.2 1.1 0.4 96 30 81 165 2.9 0 3 2.8 12/22/2005 12:40:00 0.6 0.3 1.5 0.4 0.5 0.2 1.1 0.4 0.6 0.4 1.5 0.4 88 9 78 165 2.6 0.1 2.8 2.6 12/22/2005 12:50:00 1.3 0.6 3 0.4 1.2 0.6 3 0.4 1.5 0.5 2.6 0.4 80 16 77 165 2.6 0 2.8 2.6 12/22/2005 13:00:00 1.2 0.6 2.6 0.4 1.1 0.7 2.6 0.4 1.1 0.6 2.3 0.4 97 11 87 165 2.7 0 2.8 2.6 12/22/2005 13:10:00 0.6 0.5 2.3 0.4 0.5 0.4 1.9 0.4 0.8 0.5 2.3 0.4 89 15 114 165 2.7 0 2.8 2.6 12/22/2005 13:20:00 0.7 0.5 2.3 0.4 0.6 0.4 2.3 0.4 0.7 0.5 1.9 0.4 58 21 65 165 2.6 0 2.8 2.6 12/22/2005 13:30:00 0.5 0.4 1.9 0.4 0.4 0.2 1.9 0.4 0.5 0.4 1.9 0.4 56 29 68 165 2.6 0 2.8 2.6 12/22/2005 13:40:00 0.4 0.2 1.5 0.4 0.4 0 0.4 0.4 0.4 0.2 1.5 0.4 25 9 0 165 2.7 0 2.8 2.8 12/22/2005 13:50:00 1.2 0.6 2.6 0.4 1 0.6 2.6 0.4 1.2 0.7 2.6 0.4 49 30 28 165 2.7 0 2.8 2.6 12/22/2005 14:00:00 0.4 0.2 1.1 0.4 0.4 0 0.7 0.4 0.7 0.3 1.5 0.4 20 17 6 165 2.7 0 2.8 2.6 12/22/2005 14:10:00 0.5 0.2 1.1 0.4 0.4 0.1 0.7 0.4 0.6 0.3 1.5 0.4 10 9 358 165 2.5 0 2.8 2.3 12/22/2005 14:20:00 1.2 0.4 1.9 0.4 0.8 0.4 1.9 0.4 1.4 0.5 2.3 0.4 28 7 28 165 2.4 0 2.6 2.3 12/22/2005 14:30:00 1 0.6 2.3 0.4 0.5 0.2 1.5 0.4 1.1 0.6 2.3 0.4 6 12 351 165 2.3 0 2.6 2.3 12/22/2005 14:40:00 1.7 0.2 2.3 1.1 0.7 0.5 1.9 0.4 1.8 0.2 2.3 1.5 355 4 359 165 2.1 0.1 2.6 1.8 12/22/2005 14:50:00 1.9 0.4 2.6 1.1 1.6 0.4 2.3 0.7 1.9 0.3 2.6 1.1 344 2 346 165 1.9 0 2.1 1.8 12/22/2005 15:00:00 2.3 0.2 3 1.9 1.5 0.5 2.6 0.4 2.3 0.2 3 1.5 352 3 354 165 2 0 2.1 1.8 12/22/2005 15:10:00 2 0.2 2.3 1.5 1.5 0.4 2.3 0.4 2 0.2 2.6 1.5 348 2 348 165 1.9 0 2.3 1.8 12/22/2005 15:20:00 2.1 0.2 2.6 1.5 1.5 0.5 2.6 0.4 2.1 0.3 2.6 1.1 346 5 336 165 1.9 0 1.8 1.8 12/22/2005 15:30:00 1.9 0.3 2.6 1.1 1.3 0.5 2.3 0.4 2.1 0.3 2.6 1.5 348 5 348 165 1.8 0 1.8 1.6 12/22/2005 15:40:00 2.2 0.4 3 1.1 1.9 0.4 2.6 0.7 2.4 0.4 3 1.5 346 4 349 165 1.9 0 1.8 1.8 12/22/2005 15:50:00 2.3 0.3 3.4 1.5 1.4 0.6 3 0.4 2.4 0.3 3 1.5 352 5 343 165 1.8 0 1.8 1.6 12/22/2005 16:00:00 2.5 0.3 3.4 1.9 2.1 0.6 3.4 0.4 2.7 0.3 3.4 1.9 347 6 340 165 1.7 0 2.1 1.6 12/22/2005 16:10:00 2.7 0.2 3.4 2.3 1.9 0.4 3 0.7 2.8 0.2 3.4 2.3 351 2 349 165 1.4 0.1 1.8 1.4 12/22/2005 16:20:00 2.1 0.3 2.6 1.5 1.3 0.5 2.6 0.4 2.3 0.3 3 1.5 353 5 349 165 1.4 0 1.6 1.4 12/22/2005 16:30:00 2.4 0.3 3 1.5 1 0.4 1.9 0.4 2.5 0.3 3.4 1.9 3 3 2 165 1.3 0 1.4 1.4 12/22/2005 16:40:00 2.3 0.3 3 1.5 1 0.4 1.9 0.4 2.3 0.3 3 1.5 2 5 4 165 1.4 0 1.6 1.4 12/22/2005 16:50:00 2.6 0.3 3.4 1.9 1.1 0.4 2.3 0.4 2.7 0.3 3.4 1.9 2 4 0 165 1.4 0 1.6 1.4 12/22/2005 17:00:00 2.6 0.3 3.4 1.9 1.3 0.5 3 0.4 2.7 0.3 3.4 1.9 4 7 358 165 1.5 0 1.6 1.4 12/22/2005 17:10:00 2.6 0.3 3 1.9 1.5 0.5 2.6 0.7 2.7 0.3 3.4 2.3 8 5 7 165 1.7 0 1.8 1.6 12/22/2005 17:20:00 2.8 0.3 3.4 1.9 2.5 0.4 3.4 1.5 2.9 0.3 3.4 1.9 22 5 25 165 1.8 0 1.8 1.6 12/22/2005 17:30:00 3.3 0.3 4.2 2.3 3.3 0.3 4.2 2.3 3.3 0.3 4.2 2.6 27 4 36 165 2 0 2.3 1.8 12/22/2005 17:40:00 3.3 0.3 3.8 2.6 3.3 0.2 4.2 2.6 3.3 0.2 3.8 2.6 32 3 35 165 2.1 0 2.3 1.8 12/22/2005 17:50:00 2.9 0.2 3.4 2.3 3 0.2 3.8 2.3 3.1 0.2 3.8 2.6 33 3 30 165 2.1 0 2.3 1.8 12/22/2005 18:00:00 2.6 0.2 3 1.9 2.6 0.3 3.4 1.9 2.9 0.2 3.4 2.3 36 2 36 165 2.1 0 2.3 2.1 12/22/2005 18:10:00 3.3 0.3 3.8 2.6 3.3 0.3 4.2 2.3 3.5 0.3 4.2 2.6 32 3 34 165 2.2 0 2.3 2.1 12/22/2005 18:20:00 3.8 0.3 4.6 3 3.8 0.3 4.6 3 3.9 0.3 4.6 3.4 32 4 33 165 2.1 0 2.3 1.8 12/22/2005 18:30:00 3.6 0.3 4.6 3 3.6 0.4 4.2 2.6 3.8 0.3 4.6 3 32 2 36 165 2 0 2.3 1.8 12/22/2005 18:40:00 3 0.3 3.4 2.3 3 0.3 3.4 2.3 3.3 0.4 3.8 2.3 37 1 36 165 2 0 2.3 1.8 12/22/2005 18:50:00 2.4 0.5 3.4 0.7 2.4 0.5 3.4 0.4 2.5 0.3 3.4 1.9 43 9 39 165 2 0 2.3 1.8 12/22/2005 19:00:00 2.3 0.2 3 1.9 2.3 0.3 3 1.5 2.5 0.2 3 1.9 39 3 42 165 1.9 0 2.3 1.8 12/22/2005 19:10:00 1.9 0.3 2.6 1.1 1.9 0.4 2.6 1.1 2 0.3 2.6 1.1 64 20 81 165 1.9 0 2.1 1.8 12/22/2005 19:20:00 0.5 0.3 1.9 0.4 0.5 0.3 1.5 0.4 0.6 0.4 1.5 0.4 109 14 122 165 1.8 0 2.1 1.6 12/22/2005 19:30:00 1.8 0.4 3 0.4 1.9 0.4 3 0.7 1.9 0.5 2.6 0.4 64 8 65 165 1.9 0.1 2.1 1.8 12/22/2005 19:40:00 1.9 0.3 2.6 1.1 1.9 0.3 3 1.1 2.1 0.3 3 1.5 51 6 40 165 2 0 2.3 1.8 12/22/2005 19:50:00 2.3 0.2 3 1.5 2.2 0.3 3 1.5 2.6 0.2 3 2.3 28 5 32 165 2 0 2.3 1.8 12/22/2005 20:00:00 2.5 0.3 3 1.9 2.4 0.4 3 1.5 2.7 0.3 3.4 1.9 25 2 24 165 1.8 0 2.1 1.8 12/22/2005 20:10:00 3 0.3 3.8 2.3 3.1 0.3 3.8 2.3 3.3 0.3 3.8 2.6 30 2 31 165 1.8 0 1.8 1.6 12/22/2005 20:20:00 3 0.2 3.4 2.6 3 0.2 3.8 2.3 3.2 0.2 3.8 2.6 37 2 36 165 1.7 0 1.8 1.6 12/22/2005 20:30:00 3.1 0.2 3.8 2.6 3.1 0.2 3.8 2.3 3.3 0.3 4.2 2.6 40 3 39 165 1.7 0 1.8 1.6 12/22/2005 20:40:00 2.7 0.3 3.4 1.9 2.7 0.3 3.4 1.5 2.9 0.3 3.4 2.3 39 2 37 165 1.7 0 1.8 1.6 12/22/2005 20:50:00 1.7 0.4 2.6 0.4 1.7 0.4 2.6 0.4 1.9 0.5 3 1.1 55 15 37 165 1.7 0 1.8 1.6 12/22/2005 21:00:00 1.1 0.5 2.6 0.4 1.2 0.5 2.3 0.4 1.4 0.3 2.3 0.7 73 10 70 165 1.7 0 1.8 1.6 12/22/2005 21:10:00 0.5 0.3 1.9 0.4 0.7 0.4 1.9 0.4 0.8 0.4 1.9 0.4 79 8 92 165 1.9 0 2.1 1.8 12/22/2005 21:20:00 0.4 0.2 1.5 0.4 0.7 0.3 1.9 0.4 0.6 0.3 1.1 0.4 70 4 79 165 1.9 0 2.1 1.8 12/22/2005 21:30:00 0.5 0.3 1.9 0.4 0.6 0.4 2.3 0.4 0.6 0.3 1.5 0.4 63 24 90 165 1.9 0 2.1 1.6 12/22/2005 21:40:00 1.4 0.4 2.3 0.4 1.2 0.4 2.3 0.4 1.7 0.3 2.3 1.1 17 0 17 165 1.5 0.1 1.8 1.4 12/22/2005 21:50:00 1.6 0.3 2.3 0.7 1.6 0.3 2.3 0.7 2 0.3 2.6 1.1 18 2 17 165 1.4 0 1.6 1.4 12/22/2005 22:00:00 1.4 0.3 1.9 0.7 1.4 0.3 2.3 0.7 1.5 0.3 2.3 1.1 39 11 37 165 1.7 0 1.8 1.6 12/22/2005 22:10:00 1.6 0.3 2.3 0.7 1.7 0.3 2.3 1.1 1.8 0.3 2.3 1.1 45 6 36 165 1.8 0 1.8 1.8 12/22/2005 22:20:00 2 0.3 2.6 1.5 2 0.3 2.6 1.1 2.3 0.2 2.6 1.9 29 7 25 165 1.8 0 2.1 1.6 12/22/2005 22:30:00 2.1 0.5 3 0.4 2.1 0.5 3 0.4 2.2 0.4 3 0.7 35 10 27 165 1.7 0 1.8 1.6 12/22/2005 22:40:00 1.4 0.4 1.9 0.4 1.3 0.4 1.9 0.4 1.6 0.3 2.3 0.7 59 12 41 165 1.9 0 2.1 1.8 12/22/2005 22:50:00 0.7 0.4 1.9 0.4 0.8 0.4 1.9 0.4 1.2 0.4 1.9 0.4 74 9 81 165 1.9 0 2.1 1.8 12/22/2005 23:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.5 0.2 1.1 0.4 78 0 165 165 2 0 2.3 1.8 12/22/2005 23:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0.2 1.1 0.4 55 12 165 165 2.1 0 2.3 2.1 12/22/2005 23:20:00 0.4 0.1 1.1 0.4 0.4 0.1 1.1 0.4 0.5 0.2 1.1 0.4 62 7 51 165 2.1 0 2.3 1.8 12/22/2005 23:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 62 9 165 165 1.8 0 2.3 1.6 12/22/2005 23:40:00 0.4 0 0.7 0.4 0.4 0 0.7 0.4 0.4 0 0.4 0.4 32 2 31 165 1.8 0 1.8 1.6 12/22/2005 23:50:00 0.5 0.2 1.1 0.4 0.4 0.2 1.1 0.4 0.5 0.2 1.1 0.4 47 11 58 165 1.9 0 1.8 1.8 12/23/2005 00:00:00 0.6 0.3 1.5 0.4 0.6 0.3 1.5 0.4 0.4 0.1 1.1 0.4 72 6 78 165 1.9 0 2.1 1.8 12/23/2005 00:10:00 0.4 0.1 1.1 0.4 0.4 0.1 1.1 0.4 0.6 0.3 1.5 0.4 78 1 78 165 2.1 0 2.3 1.8 12/23/2005 00:20:00 0.4 0.1 1.1 0.4 0.4 0.1 1.1 0.4 0.5 0.3 1.1 0.4 78 0 78 165 2.3 0 2.6 2.3 12/23/2005 00:30:00 0.4 0 0.7 0.4 0.4 0.1 1.1 0.4 0.5 0.3 1.5 0.4 78 11 98 165 2.4 0 2.6 2.3 12/23/2005 00:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0.2 1.5 0.4 125 3 165 165 2.2 0 2.6 2.1 12/23/2005 00:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0.1 0.7 0.4 99 16 165 165 2.1 0 2.3 1.8 12/23/2005 01:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 106 11 165 165 2.1 0 2.3 2.1 12/23/2005 01:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 113 0 165 165 2 0 2.3 1.8 12/23/2005 01:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 113 0 165 165 2 0 2.3 1.8 12/23/2005 01:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 113 0 165 165 2 0 2.3 1.8 12/23/2005 01:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 125 6 165 165 1.9 0 2.3 1.8 12/23/2005 01:50:00 0.5 0.3 1.1 0.4 0.4 0 0.4 0.4 0.6 0.4 1.5 0.4 142 16 161 165 1.9 0 2.1 1.8 12/23/2005 02:00:00 0.5 0.2 1.1 0.4 0.4 0 0.4 0.4 0.6 0.2 1.1 0.4 164 2 164 165 1.9 0 1.8 1.8 12/23/2005 02:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 165 0 165 165 1.8 0 1.8 1.6 12/23/2005 02:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 165 0 165 165 1.8 0 1.8 1.6 12/23/2005 02:30:00 0.4 0.2 1.1 0.4 0.4 0 0.7 0.4 0.4 0 0.7 0.4 359 98 43 165 1.8 0 1.8 1.6 12/23/2005 02:40:00 0.4 0.1 0.7 0.4 0.4 0 0.4 0.4 0.5 0.2 1.1 0.4 57 11 75 165 1.9 0 1.8 1.8 12/23/2005 02:50:00 0.4 0.1 1.1 0.4 0.4 0.1 0.7 0.4 0.4 0.2 1.5 0.4 47 7 44 165 2 0 2.3 1.8 12/23/2005 03:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 49 0 165 165 2 0 2.3 1.8 12/23/2005 03:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0.1 0.7 0.4 49 0 165 165 2 0 2.3 1.8 12/23/2005 03:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 49 0 165 165 1.9 0 2.1 1.8 12/23/2005 03:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 43 13 165 165 1.9 0 2.1 1.8 12/23/2005 03:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 12 0 165 165 1.9 0 1.8 1.8 12/23/2005 03:50:00 0.4 0.1 0.7 0.4 0.4 0 0.4 0.4 0.4 0 0.7 0.4 141 107 251 165 1.8 0 1.8 1.6 12/23/2005 04:00:00 0.4 0.1 1.1 0.4 0.4 0 0.4 0.4 0.4 0.1 1.1 0.4 243 0 243 165 1.9 0.1 2.3 1.6 12/23/2005 04:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 243 0 165 165 2.1 0 2.3 1.8 12/23/2005 04:20:00 0.4 0.1 0.7 0.4 0.4 0 0.4 0.4 0.4 0 0.7 0.4 243 0 243 165 2.2 0 2.3 2.1 12/23/2005 04:30:00 0.5 0.2 1.1 0.4 0.4 0 0.4 0.4 0.6 0.3 1.1 0.4 223 21 203 165 2.1 0 2.3 2.1 12/23/2005 04:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.7 0.4 192 0 165 165 2 0 2.3 1.8 12/23/2005 04:50:00 0.6 0.4 1.5 0.4 0.5 0.3 1.5 0.4 0.6 0.4 1.5 0.4 172 11 166 165 1.9 0 2.1 1.8 12/23/2005 05:00:00 0.4 0.1 1.1 0.4 0.4 0.1 0.7 0.4 0.4 0 0.4 0.4 165 0 165 165 1.9 0 2.1 1.8 12/23/2005 05:10:00 0.6 0.4 1.5 0.4 0.5 0.3 1.5 0.4 0.5 0.3 1.5 0.4 177 2 168 165 1.9 0 2.1 1.8 12/23/2005 05:20:00 0.9 0.4 1.5 0.4 0.7 0.3 1.5 0.4 1 0.4 1.9 0.4 167 4 174 165 1.9 0 2.3 1.8 12/23/2005 05:30:00 0.7 0.4 1.5 0.4 0.7 0.5 1.5 0.4 0.6 0.4 1.5 0.4 203 38 243 165 1.9 0 2.1 1.8 12/23/2005 05:40:00 0.8 0.4 1.5 0.4 0.7 0.4 1.5 0.4 0.7 0.4 1.5 0.4 245 6 247 165 2.1 0 2.3 1.8 12/23/2005 05:50:00 1.3 0.9 3 0.4 1.2 0.8 2.6 0.4 1.1 0.8 3 0.4 211 27 187 165 2.3 0.1 2.6 2.3 12/23/2005 06:00:00 1.2 0.6 2.3 0.4 1 0.6 2.3 0.4 1.4 0.7 3 0.4 179 11 196 165 2.4 0.1 2.8 2.1 12/23/2005 06:10:00 1.6 0.8 3.4 0.4 1.5 0.8 3.4 0.4 1.7 0.6 3 0.4 155 21 200 165 2.1 0.1 2.3 1.8 12/23/2005 06:20:00 1.9 0.9 3.4 0.4 1.7 0.9 3 0.4 2 0.9 3.4 0.4 149 8 160 165 1.8 0 2.3 1.6 12/23/2005 06:30:00 1.4 0.9 2.6 0.4 1.3 0.9 2.6 0.4 1.5 0.8 2.6 0.4 146 1 146 165 1.4 0 1.8 1.4 12/23/2005 06:40:00 0.6 0.3 1.5 0.4 0.6 0.3 1.5 0.4 1 0.4 1.9 0.4 121 7 137 165 1.8 0 1.8 1.6 12/23/2005 06:50:00 1.8 0.4 2.6 1.1 1.6 0.4 2.6 1.1 2 0.3 2.6 1.5 155 8 146 165 1.9 0 2.1 1.8 12/23/2005 07:00:00 1.1 0.4 1.9 0.4 1 0.4 1.9 0.4 1.5 0.3 1.9 0.7 164 5 164 165 1.8 0 1.8 1.6 12/23/2005 07:10:00 1.1 0.4 1.9 0.4 1 0.3 1.5 0.4 1.4 0.3 1.9 0.7 163 8 164 165 1.8 0 1.8 1.6 12/23/2005 07:20:00 1.3 0.4 1.9 0.4 1.2 0.3 1.9 0.4 1.6 0.2 1.9 0.7 158 9 164 165 1.8 0 1.8 1.6 12/23/2005 07:30:00 1.2 0.7 2.3 0.4 1.1 0.6 2.3 0.4 1.4 0.6 2.3 0.4 154 10 165 165 1.7 0 1.8 1.6 12/23/2005 07:40:00 0.6 0.5 2.3 0.4 0.6 0.5 1.9 0.4 0.9 0.6 2.3 0.4 165 8 164 165 1.7 0 1.8 1.6 12/23/2005 07:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 171 0 165 165 1.7 0 1.8 1.6 12/23/2005 08:00:00 0.4 0.1 0.7 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 171 0 171 165 1.9 0 1.8 1.8 12/23/2005 08:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0.1 0.7 0.4 185 29 165 165 1.8 0 2.3 1.6 12/23/2005 08:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 247 7 165 165 1.7 0 1.8 1.6 12/23/2005 08:30:00 0.6 0.3 1.1 0.4 0.4 0.2 1.1 0.4 0.8 0.5 1.9 0.4 191 22 176 165 1.7 0 1.8 1.6 12/23/2005 08:40:00 0.5 0.2 1.1 0.4 0.4 0 0.7 0.4 0.7 0.4 1.5 0.4 161 1 165 165 1.9 0 2.1 1.8 12/23/2005 08:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0.2 1.5 0.4 161 0 165 165 1.9 0 1.8 1.8 12/23/2005 09:00:00 0.4 0.2 1.5 0.4 0.4 0.2 1.5 0.4 0.6 0.5 1.9 0.4 157 8 136 165 1.9 0 1.8 1.8 12/23/2005 09:10:00 1.8 0.4 2.6 1.1 1.7 0.4 2.6 1.1 2 0.3 2.6 1.5 139 4 146 165 1.8 0 1.8 1.6 12/23/2005 09:20:00 1.8 0.6 2.6 0.7 1.7 0.5 2.6 0.7 2 0.5 2.6 0.7 157 7 147 165 1.5 0.1 1.8 1.4 12/23/2005 09:30:00 1.6 0.3 2.3 0.7 1.4 0.3 2.3 0.7 1.7 0.3 2.3 1.1 161 4 165 165 1.4 0 1.4 1.4 12/23/2005 09:40:00 1.7 0.5 2.6 0.7 1.5 0.5 2.6 0.7 1.7 0.5 2.6 0.7 163 1 162 165 1.4 0 1.6 1.4 12/23/2005 09:50:00 2.6 0.2 3 2.3 2.4 0.2 2.6 1.9 2.6 0.3 3 1.9 166 3 166 165 1.4 0 1.6 1.4 12/23/2005 10:00:00 2.2 0.5 3.4 1.5 2 0.4 3.4 1.1 2.1 0.4 3 1.5 161 11 159 165 1.4 0 1.6 1.4 12/23/2005 10:10:00 2.1 0.3 2.6 1.5 2 0.3 2.6 1.5 2 0.2 2.6 1.5 162 4 159 165 1.6 0 1.8 1.4 12/23/2005 10:20:00 2.3 0.2 3 1.9 2.1 0.2 2.6 1.5 2.3 0.3 2.6 1.9 159 3 162 165 1.9 0 1.8 1.6 12/23/2005 10:30:00 3 0.4 4.2 2.3 2.8 0.4 3.8 1.9 2.8 0.3 3.4 2.3 162 2 164 165 1.7 0 1.8 1.4 12/23/2005 10:40:00 3 0.4 3.8 1.9 2.9 0.4 3.8 1.9 2.7 0.3 3.4 1.9 166 5 170 165 1.7 0 1.8 1.6 12/23/2005 10:50:00 3 0.5 4.2 1.9 2.8 0.5 3.8 1.5 2.6 0.3 3.4 1.9 177 6 174 165 1.8 0 1.8 1.6 12/23/2005 11:00:00 2.2 0.2 2.6 1.5 2 0.3 2.6 1.5 2.2 0.2 2.6 1.5 163 3 162 165 1.8 0 1.8 1.6 12/23/2005 11:10:00 2.7 0.4 3.8 1.9 2.4 0.4 3.4 1.5 2.3 0.3 3 1.5 180 6 179 165 1.2 0 1.6 0.9 12/23/2005 11:20:00 3.4 0.4 4.2 2.6 3.2 0.4 3.8 2.6 2.9 0.4 3.8 1.9 181 5 187 165 1.1 0 1.4 0.9 12/23/2005 11:30:00 3.9 0.3 4.6 3 3.8 0.4 4.6 3 3.5 0.5 4.6 2.6 195 3 196 165 1.3 0 1.6 1.1 12/23/2005 11:40:00 3.6 0.6 4.9 2.3 3.4 0.6 4.6 2.3 3.4 0.5 4.6 2.3 182 13 183 165 1.8 0.1 1.8 1.6 12/23/2005 11:50:00 3.9 0.9 6.1 2.3 3.7 0.9 5.7 2.3 3.6 0.8 5.7 1.9 173 13 193 165 2.1 0.2 2.6 1.8 12/23/2005 12:00:00 4.9 0.6 6.1 3.4 4.7 0.6 5.7 3 4.6 0.6 5.7 2.6 177 7 177 165 2.4 0 2.8 2.3 12/23/2005 12:10:00 4.6 0.5 5.7 3 4.4 0.4 5.7 3 4.2 0.5 5.7 2.3 179 6 178 165 2.3 0 2.6 2.3 12/23/2005 12:20:00 4.7 0.4 5.7 3.4 4.5 0.4 5.3 3.4 4.6 0.4 5.7 3.8 176 6 169 165 2.7 0.2 3 2.3 12/23/2005 12:30:00 4.9 0.5 6.1 3.4 4.7 0.5 5.7 3.4 4.8 0.5 6.1 3 185 8 191 165 3.3 0.2 3.5 3 12/23/2005 12:40:00 4.2 0.6 5.7 2.6 4 0.5 5.7 2.6 4.1 0.5 5.3 2.6 177 8 182 165 3.5 0.2 3.8 3 12/23/2005 12:50:00 3.9 0.3 4.6 3 3.7 0.3 4.6 3 3.8 0.4 4.9 2.6 174 5 165 165 2.8 0 3.3 2.3 12/23/2005 13:00:00 3.9 0.3 4.9 3 3.7 0.3 4.6 3 3.8 0.3 4.6 3 178 5 184 165 2 0.1 2.6 1.8 12/23/2005 13:10:00 4.1 0.3 5.3 3.4 3.8 0.3 4.6 3 4.2 0.4 5.3 3.4 176 5 171 165 2 0 2.1 1.8 12/23/2005 13:20:00 4.4 0.4 4.9 3.4 4.2 0.3 4.9 3.4 4.4 0.4 5.3 3 177 4 172 165 1.9 0 2.1 1.8 12/23/2005 13:30:00 3.8 0.3 4.6 3 3.6 0.3 4.2 3 3.8 0.4 4.6 2.6 180 3 188 165 1.9 0 2.1 1.8 12/23/2005 13:40:00 3.4 0.4 4.6 2.6 3.3 0.3 4.2 2.3 3.5 0.4 4.6 2.6 178 5 182 165 1.8 0 2.3 1.6 12/23/2005 13:50:00 4.3 0.6 5.3 2.6 4.1 0.5 4.9 2.6 4.2 0.4 5.3 3.4 174 4 175 165 1.5 0 1.8 1.4 12/23/2005 14:00:00 4.8 0.3 5.3 4.2 4.6 0.3 5.3 3.8 4.7 0.4 5.3 3.8 179 6 171 165 1.7 0 1.8 1.4 12/23/2005 14:10:00 4.8 0.3 5.3 4.2 4.7 0.3 5.3 3.8 4.8 0.4 5.7 3.8 184 5 192 165 1.9 0 1.8 1.6 12/23/2005 14:20:00 4 0.4 4.9 3 3.9 0.4 4.6 3 3.8 0.4 4.9 2.6 182 5 186 165 1.7 0 1.8 1.6 12/23/2005 14:30:00 4.4 0.3 5.3 3.4 4.3 0.3 4.9 3.4 4.2 0.4 4.9 3 180 2 180 165 1.6 0 1.8 1.6 12/23/2005 14:40:00 3.7 0.3 4.2 3 3.6 0.3 4.2 3 3.5 0.3 4.2 2.6 183 3 177 165 1.5 0 1.6 1.4 12/23/2005 14:50:00 3.3 0.4 3.8 2.3 3.3 0.4 4.2 2.3 3.1 0.4 4.2 2.3 188 5 188 165 1.7 0 1.8 1.6 12/23/2005 15:00:00 3.7 0.3 4.2 3 3.6 0.3 4.2 3 3.4 0.4 4.2 2.6 185 5 187 165 1.8 0 1.8 1.6 12/23/2005 15:10:00 2 0.6 3.4 1.1 2.1 0.6 3.4 1.1 1.8 0.7 3.4 0.4 190 13 178 165 1.7 0 1.8 1.6 12/23/2005 15:20:00 2.6 0.2 3 1.9 2.6 0.2 3 1.9 2.4 0.4 3 1.1 189 7 196 165 1.8 0.1 1.8 1.6 12/23/2005 15:30:00 3.2 0.3 3.8 2.6 3.1 0.3 3.8 2.6 3.1 0.3 3.8 2.3 171 5 177 165 1.9 0 1.8 1.8 12/23/2005 15:40:00 2.4 0.4 3.4 1.5 2.3 0.4 3 1.5 2.4 0.4 3 1.5 148 10 156 165 1.7 0 1.8 1.4 12/23/2005 15:50:00 2.5 0.3 3.4 1.9 2.4 0.4 3 1.5 2.6 0.3 3.4 1.9 158 3 154 165 1.4 0 1.8 1.4 12/23/2005 16:00:00 2.7 0.4 3.4 1.5 2.5 0.4 3 1.5 2.4 0.3 3 1.9 162 5 165 165 1.4 0 1.6 1.4 12/23/2005 16:10:00 2.6 0.2 3.4 2.3 2.5 0.2 3 1.9 2.5 0.2 3 1.9 152 3 151 165 1.5 0 1.6 1.4 12/23/2005 16:20:00 2.2 0.3 2.6 1.5 2 0.3 2.6 1.5 2.2 0.3 2.6 1.5 143 2 148 165 1.5 0 1.6 1.4 12/23/2005 16:30:00 2.4 0.5 3.4 0.7 2.1 0.5 3 0.4 2.2 0.5 3 0.7 151 7 145 165 1.6 0 1.6 1.6 12/23/2005 16:40:00 2.1 0.2 2.6 1.5 2 0.2 2.6 1.1 2.1 0.2 2.6 1.5 152 5 151 165 1.7 0 1.8 1.6 12/23/2005 16:50:00 2.5 0.5 3.4 1.5 2.4 0.5 3.4 1.5 2.4 0.4 3.4 1.5 148 6 139 165 1.6 0 1.8 1.6 12/23/2005 17:00:00 3 0.3 3.8 2.3 2.9 0.4 3.8 1.9 2.9 0.3 3.8 2.3 150 4 151 165 1.7 0 1.8 1.6 12/23/2005 17:10:00 3 0.4 3.8 1.9 2.9 0.4 4.2 1.5 2.9 0.4 4.2 1.9 152 7 156 165 1.7 0 1.8 1.6 12/23/2005 17:20:00 2.8 0.8 5.3 1.1 2.8 0.8 5.3 1.1 2.8 0.7 4.6 1.5 144 12 136 165 1.8 0 1.8 1.6 12/23/2005 17:30:00 3.4 0.5 4.6 2.3 3.3 0.5 4.2 2.3 3.3 0.5 4.6 2.3 146 6 149 165 1.9 0 1.8 1.8 12/23/2005 17:40:00 3.4 0.5 4.6 1.9 3.3 0.5 4.6 1.9 3.3 0.5 4.2 1.9 149 8 151 165 1.9 0 1.8 1.8 12/23/2005 17:50:00 3.5 0.5 4.6 2.3 3.5 0.6 4.6 1.9 3.5 0.5 4.9 1.9 150 7 145 165 1.9 0 1.8 1.8 12/23/2005 18:00:00 3.6 0.4 4.6 2.6 3.5 0.4 4.6 2.3 3.6 0.5 4.6 2.3 155 11 151 165 1.9 0 2.1 1.8 12/23/2005 18:10:00 3.7 0.5 5.3 2.6 3.6 0.5 5.3 2.6 3.5 0.5 4.9 2.6 158 8 154 165 1.8 0 1.8 1.6 12/23/2005 18:20:00 4 0.6 5.3 2.3 3.9 0.6 5.3 2.3 4 0.6 5.3 2.3 154 6 152 165 1.8 0 1.8 1.6 12/23/2005 18:30:00 4.3 0.4 5.3 3.4 4.3 0.4 5.3 3.4 4.2 0.5 5.3 3 149 6 152 165 1.8 0 1.8 1.6 12/23/2005 18:40:00 4 0.7 5.3 2.3 3.9 0.6 5.3 2.3 3.9 0.7 5.3 2.3 147 6 155 165 1.8 0 1.8 1.6 12/23/2005 18:50:00 3.9 0.5 5.3 2.6 3.9 0.5 5.3 2.6 3.8 0.5 5.3 2.3 148 8 161 165 1.8 0 1.8 1.6 12/23/2005 19:00:00 4.1 0.5 5.3 3 4.1 0.5 5.3 3 4 0.5 5.3 3 147 6 153 165 1.8 0 1.8 1.8 12/23/2005 19:10:00 3.2 0.7 4.9 1.9 3.2 0.7 4.9 1.9 3.1 0.6 5.3 1.9 147 8 145 165 1.8 0 1.8 1.8 12/23/2005 19:20:00 3.9 0.4 4.9 3 3.9 0.3 4.6 3 3.9 0.4 4.6 3 145 6 147 165 1.9 0 1.8 1.8 12/23/2005 19:30:00 3.9 0.5 4.9 2.3 3.9 0.5 4.9 1.9 3.9 0.6 4.9 2.3 145 6 140 165 1.9 0 1.8 1.8 12/23/2005 19:40:00 4.7 0.5 6.5 3.8 4.7 0.5 6.5 3.8 4.6 0.5 6.1 3.4 145 8 145 165 1.9 0 1.8 1.8 12/23/2005 19:50:00 5.3 0.5 6.8 4.2 5.4 0.5 6.8 4.6 5.2 0.5 6.8 4.2 140 6 147 165 1.9 0 1.8 1.8 12/23/2005 20:00:00 5 0.5 6.1 3.4 5 0.5 6.5 3.4 4.9 0.5 6.1 3.4 145 4 144 165 1.9 0 2.3 1.8 12/23/2005 20:10:00 5.7 1.2 8 3.4 5.8 1.3 8 3.4 5.6 1.3 8.4 3.4 133 8 122 165 1.9 0 2.1 1.8 12/23/2005 20:20:00 6.8 0.7 8.4 5.3 7 0.7 8.4 5.3 6.8 0.7 8.8 4.9 138 5 134 165 1.9 0 1.8 1.8 12/23/2005 20:30:00 6.5 0.5 7.6 5.3 6.7 0.5 8 5.7 6.6 0.6 7.6 4.6 136 6 133 165 1.9 0 2.1 1.8 12/23/2005 20:40:00 6.9 0.7 8.4 5.3 7.1 0.6 8.8 5.3 7 0.7 9.1 4.9 126 5 126 165 1.9 0 1.8 1.8 12/23/2005 20:50:00 7.9 0.5 9.1 6.5 8 0.5 9.5 6.5 7.9 0.6 10.3 6.1 125 6 114 165 2 0 2.1 1.8 12/23/2005 21:00:00 8.3 0.6 10.7 6.8 8.5 0.6 11.1 7.2 8.4 0.7 11.1 6.8 130 6 129 165 2 0 2.3 1.8 12/23/2005 21:10:00 7.1 0.7 9.1 5.3 7.1 0.7 8.8 5.3 7.1 0.6 9.1 5.7 135 6 136 165 2.1 0 2.3 1.8 12/23/2005 21:20:00 6.8 0.6 8.4 4.6 6.9 0.6 8.4 4.6 6.8 0.6 8 4.6 135 6 130 165 2.1 0 2.3 2.1 12/23/2005 21:30:00 7.4 0.7 9.1 6.1 7.5 0.7 9.1 6.1 7.4 0.7 9.1 5.7 131 9 122 165 2.1 0 2.3 2.1 12/23/2005 21:40:00 7.6 0.7 9.5 5.7 7.7 0.7 9.5 5.7 7.5 0.8 9.9 5.3 134 8 153 165 2.1 0 2.3 2.1 12/23/2005 21:50:00 8 1 10.3 5.3 8 1 9.9 5.3 7.9 1 9.9 4.9 140 7 148 165 2.2 0 2.3 2.1 12/23/2005 22:00:00 8.5 0.5 9.9 7.2 8.5 0.5 9.9 7.2 8.5 0.5 10.3 7.2 152 3 154 165 2.3 0 2.6 2.3 12/23/2005 22:10:00 8.9 0.8 11.1 7.2 8.9 0.8 11.1 6.8 8.8 0.9 11.1 6.5 142 6 148 165 2.3 0 2.6 2.3 12/23/2005 22:20:00 9.2 0.8 11.5 7.2 9.1 0.8 11.1 7.2 9 0.9 11.1 6.5 143 6 141 165 2.3 0 2.6 2.3 12/23/2005 22:30:00 10.1 0.6 11.5 8.4 10.2 0.6 11.5 8.4 10 0.7 11.5 6.8 147 4 145 165 2.4 0 2.6 2.3 12/23/2005 22:40:00 9.8 0.6 11.5 8 9.8 0.6 11.1 8.4 9.8 0.8 11.5 7.6 147 4 153 165 2.4 0 2.6 2.3 12/23/2005 22:50:00 8.9 0.8 11.1 7.2 8.9 0.8 10.7 7.2 8.8 0.8 11.1 6.8 142 5 143 165 2.4 0 2.6 2.3 12/23/2005 23:00:00 9.6 0.8 11.1 6.8 9.6 0.8 11.1 6.8 9.4 0.8 11.1 7.2 140 5 137 165 2.4 0 2.6 2.3 12/23/2005 23:10:00 10.5 1 12.2 7.6 10.5 1 12.2 8 10.5 1.1 12.6 8 146 6 148 165 2.4 0 2.6 2.3 12/23/2005 23:20:00 10.3 0.8 11.5 7.6 10.3 0.7 11.5 8 10.3 0.9 11.8 8 147 4 152 165 2.3 0 2.6 2.3 12/23/2005 23:30:00 10.2 0.5 11.5 9.1 10.3 0.5 11.8 8.8 10.1 0.7 11.8 7.6 148 4 145 165 2.3 0 2.6 2.3 12/23/2005 23:40:00 8.2 0.6 9.5 6.5 8.2 0.6 9.9 6.8 8.2 0.7 9.9 6.5 149 3 145 165 2.3 0 2.6 2.3 12/23/2005 23:50:00 8 0.4 9.1 7.2 8 0.3 9.1 7.2 8 0.4 9.5 7.2 146 3 148 165 2.3 0 2.6 2.3 12/24/2005 00:00:00 8.3 0.5 9.9 6.8 8.3 0.5 9.5 6.8 8.2 0.5 9.1 6.1 144 5 136 165 2.4 0 2.6 2.3 12/24/2005 00:10:00 9 0.9 11.1 6.5 9 0.8 10.7 6.8 8.9 1 11.1 6.5 142 4 138 165 2.3 0 2.6 2.3 12/24/2005 00:20:00 7.7 0.6 9.1 6.1 7.8 0.6 9.5 6.1 7.6 0.7 9.1 6.1 139 7 136 165 2.3 0 2.3 2.3 12/24/2005 00:30:00 7.5 0.8 9.1 4.6 7.5 0.8 9.5 4.6 7.2 0.9 9.1 4.6 142 6 133 165 2.1 0 2.3 1.8 12/24/2005 00:40:00 6.8 0.7 8.8 4.9 6.9 0.7 8.8 4.9 6.8 0.8 8.4 4.6 143 6 139 165 2 0 2.3 1.8 12/24/2005 00:50:00 7.2 0.9 8.8 4.6 7.2 0.9 8.8 4.9 7 1.1 8.8 4.2 140 6 142 165 2.1 0 2.3 2.1 12/24/2005 01:00:00 8.8 1.7 11.8 6.1 8.9 1.7 12.2 6.5 8.7 1.8 12.2 5.3 144 6 145 165 2.2 0 2.3 1.8 12/24/2005 01:10:00 9.2 0.7 10.7 7.2 9.3 0.7 11.1 7.6 9.2 0.9 11.1 6.5 148 3 151 165 1.9 0 2.3 1.8 12/24/2005 01:20:00 7.7 0.8 9.1 5.7 7.8 0.8 9.1 5.7 7.6 0.8 9.1 5.3 139 5 148 165 1.8 0 1.8 1.8 12/24/2005 01:30:00 7 0.5 8.4 5.7 7.1 0.6 8.8 5.7 6.9 0.6 8.4 4.9 137 7 133 165 1.9 0 1.8 1.8 12/24/2005 01:40:00 7.5 0.5 9.1 5.7 7.6 0.5 9.5 5.7 7.4 0.6 8.8 5.3 128 5 128 165 1.9 0 2.1 1.8 12/24/2005 01:50:00 7.2 0.4 8.4 6.1 7.3 0.4 8.4 6.1 7.2 0.5 9.1 6.1 126 4 124 165 2 0 2.3 1.8 12/24/2005 02:00:00 7.2 0.5 8.8 5.7 7.4 0.5 8.8 6.1 7.1 0.5 8.4 5.3 123 3 123 165 2 0 2.1 1.8 12/24/2005 02:10:00 6.7 0.8 9.1 4.9 6.8 0.9 9.1 4.9 6.7 0.9 8.8 4.9 142 11 128 165 1.9 0 2.1 1.8 12/24/2005 02:20:00 5.8 0.6 7.2 4.6 5.9 0.6 7.2 4.6 5.6 0.6 7.2 4.2 128 5 129 165 1.8 0 2.1 1.6 12/24/2005 02:30:00 5.5 0.6 6.8 3.8 5.5 0.6 6.8 3.4 5.4 0.6 6.8 3.8 133 7 123 165 1.8 0 1.8 1.6 12/24/2005 02:40:00 6.2 0.6 8 4.9 6.3 0.6 8 4.6 6.2 0.6 8 4.6 133 7 131 165 1.8 0 1.8 1.8 12/24/2005 02:50:00 6.6 0.6 8 4.9 6.8 0.6 8 4.9 6.5 0.7 8.4 4.2 122 6 113 165 1.8 0 1.8 1.6 12/24/2005 03:00:00 7.3 1 9.9 5.3 7.4 1 9.9 5.3 7.3 1.1 10.3 5.3 127 5 141 165 1.7 0 1.8 1.6 12/24/2005 03:10:00 6.7 0.8 8.8 4.6 6.7 0.8 8.8 4.6 6.7 0.8 8.8 4.9 132 6 138 165 1.8 0 1.8 1.6 12/24/2005 03:20:00 6.9 1.2 9.9 4.6 7 1.2 10.3 4.9 6.9 1.1 10.3 4.6 125 8 116 165 1.9 0 1.8 1.8 12/24/2005 03:30:00 7.9 0.8 10.3 6.1 8 0.8 9.9 6.1 7.9 0.9 10.3 5.3 117 0 117 165 1.7 0 1.8 1.6 12/24/2005 03:40:00 7.2 0.6 9.1 5.7 7.3 0.7 9.5 5.7 7.1 0.7 9.1 5.7 118 0 118 165 1.7 0 1.8 1.6 12/24/2005 03:50:00 6.4 0.5 7.6 4.9 6.5 0.5 7.6 5.3 6.2 0.6 7.6 4.9 118 0 118 165 1.8 0 1.8 1.6 12/24/2005 04:00:00 5.4 0.6 7.2 3.8 5.5 0.6 7.2 3.8 5.3 0.7 6.8 3.4 123 4 119 165 1.8 0 1.8 1.6 12/24/2005 04:10:00 4.8 0.5 6.5 3.4 4.9 0.6 6.5 3.4 4.7 0.6 6.8 3 127 3 129 165 1.9 0 1.8 1.8 12/24/2005 04:20:00 6.1 1.1 8 3.4 6.2 1.1 8 3 5.7 1.2 8.4 3 118 4 116 165 1.9 0 1.8 1.8 12/24/2005 04:30:00 7.3 0.6 8.4 5.3 7.5 0.6 8.8 5.3 7 0.8 8.4 4.9 115 0 116 165 1.9 0 1.8 1.8 12/24/2005 04:40:00 7 0.4 8 6.1 7.3 0.4 8 6.1 6.9 0.6 8.4 4.9 115 0 115 165 1.9 0 1.8 1.8 12/24/2005 04:50:00 6.8 0.4 8 5.7 7 0.4 8 5.7 6.6 0.6 7.6 4.9 115 0 115 165 1.9 0 2.1 1.8 12/24/2005 05:00:00 6.7 0.5 7.6 4.6 6.9 0.5 7.6 4.6 6.4 0.6 7.6 4.2 115 0 115 165 1.9 0 1.8 1.8 12/24/2005 05:10:00 6.7 0.7 8 4.2 6.9 0.7 8.4 4.2 6.2 0.8 8 4.2 115 0 115 165 1.9 0 1.8 1.8 12/24/2005 05:20:00 6.4 0.7 8 4.6 6.5 0.7 8 4.2 5.8 0.8 7.6 3.8 115 0 115 165 1.9 0 2.1 1.8 12/24/2005 05:30:00 6.4 0.5 7.6 4.2 6.5 0.5 7.6 4.2 5.7 0.7 6.8 4.2 115 0 115 165 1.9 0 2.1 1.8 12/24/2005 05:40:00 5.7 0.5 7.2 4.2 5.9 0.5 7.2 4.6 5.4 0.5 6.5 3.8 115 0 115 165 1.9 0 2.1 1.8 12/24/2005 05:50:00 6.2 0.4 7.2 4.2 6.3 0.4 7.2 4.2 5.9 0.5 6.8 4.6 115 0 115 165 1.9 0 2.3 1.8 12/24/2005 06:00:00 6.2 0.6 7.2 4.6 6.4 0.6 7.6 4.6 5.9 0.7 7.2 3.8 115 0 115 165 1.9 0 1.8 1.8 12/24/2005 06:10:00 6 0.4 6.8 4.2 6.1 0.5 6.8 4.2 5.8 0.5 6.8 4.6 115 0 115 165 1.9 0 2.1 1.8 12/24/2005 06:20:00 5.9 0.3 6.5 4.6 6 0.3 6.8 4.9 5.5 0.5 6.5 4.2 115 0 115 165 1.9 0 2.1 1.8 12/24/2005 06:30:00 6.1 0.5 7.2 4.9 6.2 0.5 7.2 4.6 5.8 0.5 7.2 4.6 114 0 115 165 1.9 0 2.1 1.8 12/24/2005 06:40:00 5.8 0.3 6.8 4.9 5.9 0.3 6.8 5.3 5.6 0.4 6.5 4.6 114 0 115 165 2 0 2.3 1.8 12/24/2005 06:50:00 5.3 0.5 6.5 4.2 5.4 0.5 6.5 4.6 5 0.5 6.1 3.8 114 0 114 165 2 0 2.3 1.8 12/24/2005 07:00:00 4 0.4 5.3 3 4.1 0.4 5.3 3 3.8 0.5 4.9 2.6 114 0 114 165 1.9 0 2.3 1.8 12/24/2005 07:10:00 5.1 0.6 6.1 3.8 5.2 0.6 6.5 4.2 4.9 0.6 6.5 3.8 114 0 114 165 2.1 0 2.3 1.8 12/24/2005 07:20:00 5.5 0.5 6.5 4.2 5.6 0.5 6.8 4.2 5.2 0.6 6.5 3.8 114 0 114 165 2.1 0 2.3 2.1 12/24/2005 07:30:00 5.1 0.7 6.1 3.4 5.2 0.7 6.5 3.4 4.9 0.7 6.1 3 114 0 114 165 2.1 0 2.3 2.1 12/24/2005 07:40:00 4.7 0.6 5.7 3 4.8 0.6 5.7 3 4.3 0.6 5.7 2.6 104 18 73 165 2.1 0 2.3 2.1 12/24/2005 07:50:00 4.8 0.4 5.7 3.8 4.9 0.3 5.7 3.8 4.6 0.4 5.7 3.8 73 3 72 165 2.1 0 2.3 1.8 12/24/2005 08:00:00 4.5 0.3 5.3 3.4 4.6 0.3 5.3 3.8 4.4 0.4 5.3 3.4 80 3 84 165 2.1 0 2.3 1.8 12/24/2005 08:10:00 4.9 0.3 5.3 3.8 5 0.3 5.3 4.2 4.8 0.4 5.7 3.8 83 3 81 165 2.1 0 2.3 1.8 12/24/2005 08:20:00 4.4 0.3 5.3 3.8 4.5 0.3 5.3 3.8 4.2 0.4 5.3 3 78 4 77 165 2.1 0 2.3 1.8 12/24/2005 08:30:00 4.5 0.2 4.9 3.8 4.6 0.2 4.9 4.2 4.4 0.3 4.9 3.4 75 2 74 165 2.1 0 2.3 2.1 12/24/2005 08:40:00 4.3 0.4 4.9 3 4.4 0.4 4.9 3 4.2 0.3 4.9 3.4 72 4 77 165 2.2 0 2.3 2.3 12/24/2005 08:50:00 4.3 0.3 4.9 3.8 4.3 0.3 5.3 3.8 4.2 0.3 4.9 3 69 5 72 165 2.2 0 2.3 2.3 12/24/2005 09:00:00 5.1 0.4 6.1 3.8 5.2 0.4 6.1 3.8 4.8 0.4 5.7 3.8 85 7 87 165 2.3 0 2.3 2.3 12/24/2005 09:10:00 4.4 0.6 6.1 2.6 4.5 0.7 6.1 2.6 4.2 0.7 5.7 2.3 75 13 61 165 2.3 0 2.6 2.1 12/24/2005 09:20:00 5.2 0.4 6.1 3.8 5.3 0.4 6.1 3.8 5 0.4 5.7 4.2 67 3 61 165 2.1 0 2.3 2.1 12/24/2005 09:30:00 4.6 0.4 5.7 3.8 4.6 0.4 5.7 3.8 4.4 0.4 5.3 3.4 60 6 70 165 2.2 0 2.3 2.1 12/24/2005 09:40:00 5.1 0.4 6.1 4.2 5.1 0.4 6.1 4.2 4.9 0.5 5.7 3.4 50 2 50 165 2.1 0 2.3 2.1 12/24/2005 09:50:00 4.9 0.4 5.7 3.4 5 0.5 6.1 3 4.7 0.5 5.7 3.4 47 4 53 165 2.1 0 2.3 1.8 12/24/2005 10:00:00 4.4 0.3 5.3 3 4.3 0.4 5.3 3 4.1 0.4 5.3 2.6 43 5 44 165 2.1 0 2.3 1.8 12/24/2005 10:10:00 4.7 0.4 5.7 3.8 4.7 0.4 5.7 3.8 4.5 0.4 5.7 3.4 43 4 43 165 2.1 0 2.3 2.1 12/24/2005 10:20:00 4.4 0.5 5.3 3 4.5 0.6 5.7 3 4.4 0.6 5.3 2.6 53 6 46 165 2.1 0 2.3 1.8 12/24/2005 10:30:00 3.9 0.4 4.9 2.6 3.9 0.5 4.9 2.6 3.8 0.4 4.9 2.3 56 8 53 165 2.1 0 2.3 1.8 12/24/2005 10:40:00 4.4 0.7 6.1 2.3 4.4 0.7 6.1 2.3 4.1 0.6 5.7 2.3 53 7 50 165 2.3 0 2.6 2.3 12/24/2005 10:50:00 5.5 0.5 6.5 4.2 5.6 0.6 6.8 3.8 5.3 0.6 6.5 3.4 58 5 60 165 2.4 0 2.6 2.3 12/24/2005 11:00:00 5.2 0.4 6.1 3.8 5.4 0.4 6.1 4.2 5.1 0.5 6.5 3.4 65 5 61 165 2.5 0 2.6 2.6 12/24/2005 11:10:00 5.2 0.4 6.1 3.4 5.4 0.5 6.5 3.8 5 0.5 6.1 3.4 79 9 75 165 2.6 0 2.8 2.6 12/24/2005 11:20:00 4.6 0.4 5.3 3 4.8 0.4 5.7 3.4 4.4 0.5 5.3 2.6 93 4 92 165 2.8 0 3.3 2.6 12/24/2005 11:30:00 4.5 0.5 5.7 3.4 4.6 0.6 6.1 3 4.2 0.6 5.3 2.3 96 8 98 165 3.5 0 3.5 3.3 12/24/2005 11:40:00 3.6 0.7 5.7 2.3 3.6 0.7 5.7 1.9 3.4 0.8 6.1 1.9 100 10 106 165 3.8 0.1 4 3.5 12/24/2005 11:50:00 4 0.7 5.7 2.3 4 0.7 5.7 1.9 3.7 0.6 5.3 1.5 92 12 109 165 3.5 0 3.8 3.3 12/24/2005 12:00:00 3.9 0.6 5.3 2.3 3.9 0.6 5.3 2.3 3.6 0.6 5.3 2.3 87 7 97 165 3.3 0 3.5 3.3 12/24/2005 12:10:00 3.5 0.4 4.2 2.3 3.6 0.4 4.6 2.6 3.2 0.4 4.2 2.3 87 6 86 165 3.3 0 3.5 3.3 12/24/2005 12:20:00 3.8 0.4 4.6 2.6 3.9 0.4 4.9 3 3.6 0.5 4.9 2.3 98 8 95 165 3.7 0.1 4.3 3.5 12/24/2005 12:30:00 3.6 0.5 4.9 2.3 3.7 0.5 4.9 2.3 3.4 0.5 4.9 2.3 102 9 96 165 4 0 4.3 3.8 12/24/2005 12:40:00 3.3 0.5 4.6 1.5 3.3 0.6 4.9 1.5 3 0.5 4.6 1.5 109 9 111 165 3.8 0.1 4 3.5 12/24/2005 12:50:00 2.4 0.7 3.8 0.4 2.4 0.7 3.8 0.7 2 0.8 3.8 0.4 111 12 117 165 3.6 0 3.8 3.5 12/24/2005 13:00:00 2.3 0.4 3.4 1.1 2.2 0.5 3.4 1.1 2.1 0.4 3 0.7 101 15 108 165 3.5 0 3.5 3.3 12/24/2005 13:10:00 2 0.5 3 0.7 2 0.5 3 0.7 1.8 0.5 3 0.4 89 10 81 165 3.4 0 3.5 3.3 12/24/2005 13:20:00 2.1 0.6 3.4 0.7 2 0.6 3.8 0.4 1.8 0.6 3 0.4 102 12 102 165 3.5 0 3.5 3.5 12/24/2005 13:30:00 2.3 0.6 3.4 0.7 2.3 0.6 3.4 0.4 2 0.7 3.4 0.4 97 13 117 165 3.5 0 3.8 3.3 12/24/2005 13:40:00 2 0.5 3.4 0.7 2 0.6 3.4 0.7 1.9 0.5 3 0.7 89 9 94 165 3.2 0.1 3.5 3 12/24/2005 13:50:00 0.9 0.7 2.6 0.4 0.9 0.7 2.6 0.4 1 0.6 2.3 0.4 96 8 81 165 3 0 3.3 3 12/24/2005 14:00:00 1.1 0.4 2.3 0.4 1.1 0.5 2.3 0.4 1.1 0.5 2.3 0.4 114 7 116 165 3.1 0 3.3 3 12/24/2005 14:10:00 1.1 0.4 1.9 0.4 1 0.5 1.9 0.4 0.8 0.5 1.9 0.4 117 8 107 165 3 0 3.3 3 12/24/2005 14:20:00 1.2 0.3 1.9 0.4 0.8 0.4 1.9 0.4 1.1 0.4 2.3 0.4 130 7 126 165 3 0 3.3 2.8 12/24/2005 14:30:00 0.5 0.2 1.5 0.4 0.4 0.2 1.1 0.4 0.4 0 0.7 0.4 142 2 139 165 3 0 3 2.8 12/24/2005 14:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 144 0 165 165 2.8 0 3 2.6 12/24/2005 14:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 146 2 165 165 2.5 0 2.8 2.6 12/24/2005 15:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 148 0 165 165 2.5 0 2.8 2.6 12/24/2005 15:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 148 0 165 165 2.4 0 2.6 2.3 12/24/2005 15:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 148 0 165 165 2.3 0 2.6 2.3 12/24/2005 15:30:00 0.4 0.1 1.1 0.4 0.4 0 0.4 0.4 0.4 0.2 1.1 0.4 148 0 148 165 2.3 0 2.3 2.3 12/24/2005 15:40:00 0.6 0.3 1.5 0.4 0.5 0.2 1.1 0.4 0.7 0.3 1.5 0.4 18 76 334 165 2.2 0 2.6 2.1 12/24/2005 15:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 334 0 165 165 2.1 0 2.3 2.1 12/24/2005 16:00:00 0.4 0.2 0.7 0.4 0.4 0 0.4 0.4 0.4 0.2 1.1 0.4 334 0 334 165 2 0 2.3 1.8 12/24/2005 16:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 334 0 165 165 1.9 0 2.1 1.8 12/24/2005 16:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 301 28 165 165 2 0 2.3 1.8 12/24/2005 16:30:00 0.7 0.4 1.5 0.4 0.7 0.3 1.5 0.4 1.3 0.4 1.9 0.4 242 11 238 165 2 0 2.3 1.8 12/24/2005 16:40:00 0.5 0.2 1.1 0.4 0.4 0 0.7 0.4 1.1 0.2 1.5 0.4 235 0 235 165 2 0 2.3 1.8 12/24/2005 16:50:00 1.1 0.3 1.9 0.7 0.9 0.3 1.5 0.4 1.3 0.2 1.9 1.1 234 3 230 165 2.1 0 2.3 1.8 12/24/2005 17:00:00 0.8 0.3 1.5 0.4 0.6 0.3 1.1 0.4 1 0.3 1.9 0.4 225 0 225 165 2.1 0 2.3 2.1 12/24/2005 17:10:00 0.4 0.1 0.7 0.4 0.4 0 0.4 0.4 0.5 0.2 1.5 0.4 267 43 225 165 2.1 0 2.3 2.1 12/24/2005 17:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0.1 0.7 0.4 305 9 165 165 2 0 2.3 1.8 12/24/2005 17:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 281 0 165 165 2 0 2.3 1.8 12/24/2005 17:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 281 0 165 165 2.1 0 2.3 2.1 12/24/2005 17:50:00 0.4 0.1 1.1 0.4 0.4 0 0.7 0.4 0.4 0.3 1.5 0.4 276 8 264 165 2.2 0 2.3 2.1 12/24/2005 18:00:00 0.8 0.5 1.9 0.4 0.7 0.4 1.9 0.4 1.2 0.5 2.3 0.4 211 10 205 165 2.2 0 2.3 2.1 12/24/2005 18:10:00 1 0.4 1.5 0.4 0.7 0.3 1.5 0.4 1.1 0.4 1.9 0.4 204 0 204 165 2.2 0 2.3 2.3 12/24/2005 18:20:00 0.8 0.2 1.1 0.4 0.4 0 0.4 0.4 0.9 0.2 1.5 0.4 196 5 204 165 2.3 0 2.6 2.3 12/24/2005 18:30:00 1 0.3 1.5 0.4 0.5 0.3 1.5 0.4 1.2 0.2 1.9 0.7 185 6 191 165 2.2 0 2.3 2.1 12/24/2005 18:40:00 1.8 0.5 2.6 0.7 1.6 0.5 2.6 0.4 1.9 0.5 2.6 0.7 187 6 187 165 2.2 0 2.3 2.3 12/24/2005 18:50:00 1.6 0.3 2.3 1.1 1.3 0.3 1.9 0.4 1.7 0.3 2.3 1.1 174 5 179 165 2.2 0 2.3 2.1 12/24/2005 19:00:00 1.7 0.2 2.3 1.1 1.5 0.3 1.9 0.7 1.7 0.2 2.3 1.1 168 3 169 165 2.2 0 2.3 2.1 12/24/2005 19:10:00 0.9 0.4 1.9 0.4 0.6 0.4 1.5 0.4 1 0.4 1.9 0.4 167 8 165 165 2.2 0 2.6 2.1 12/24/2005 19:20:00 2 0.3 3 1.5 1.8 0.3 2.6 1.1 1.9 0.3 2.6 1.1 143 3 142 165 2.3 0 2.6 2.3 12/24/2005 19:30:00 2.3 0.5 3.4 1.1 2.1 0.5 3 0.7 2.2 0.4 3 1.1 146 3 150 165 2.3 0 2.6 2.3 12/24/2005 19:40:00 1.9 0.3 2.6 1.1 1.7 0.3 2.3 0.7 1.8 0.3 2.3 1.1 146 3 145 165 2.3 0 2.3 2.3 12/24/2005 19:50:00 1.7 0.2 2.3 1.1 1.6 0.2 1.9 1.1 1.8 0.2 2.3 1.1 147 2 148 165 2.3 0 2.3 2.1 12/24/2005 20:00:00 1.5 0.3 2.6 0.7 1.4 0.3 2.3 0.7 1.7 0.2 2.3 1.1 152 6 148 165 2.2 0 2.3 2.1 12/24/2005 20:10:00 2.2 0.3 3 1.5 2 0.3 3 1.5 2.1 0.2 2.6 1.5 152 5 146 165 2.2 0 2.3 2.3 12/24/2005 20:20:00 2.9 0.5 4.2 1.9 2.8 0.5 4.2 1.9 2.8 0.5 4.2 1.9 163 5 164 165 2.2 0 2.6 2.1 12/24/2005 20:30:00 2.7 0.4 3.4 1.9 2.5 0.4 3.4 1.5 2.7 0.4 3.8 1.9 162 3 157 165 2 0 2.3 1.8 12/24/2005 20:40:00 3.4 0.7 4.9 2.3 3.2 0.7 4.6 1.9 3.1 0.6 4.6 1.9 145 7 150 165 2 0 2.3 1.8 12/24/2005 20:50:00 4.3 0.4 5.3 3.4 4.2 0.4 5.3 3.4 4 0.4 5.3 3 141 9 140 165 2.1 0 2.3 2.1 12/24/2005 21:00:00 3.6 0.5 5.3 2.6 3.5 0.5 4.9 2.6 3.5 0.5 4.9 2.3 141 7 144 165 2.2 0 2.3 2.1 12/24/2005 21:10:00 3.3 0.3 4.2 2.6 3.2 0.3 4.2 2.3 3.4 0.3 4.2 2.6 149 9 153 165 2.2 0 2.3 2.1 12/24/2005 21:20:00 4.7 0.8 6.8 3 4.7 0.8 6.8 3.4 4.6 0.8 6.5 3.4 155 9 157 165 2.1 0 2.3 1.8 12/24/2005 21:30:00 6 0.5 7.2 4.6 5.9 0.5 7.2 4.6 6 0.5 7.2 4.6 153 6 146 165 2.2 0 2.3 2.1 12/24/2005 21:40:00 5.5 0.6 6.8 4.2 5.4 0.5 6.8 4.2 5.5 0.5 6.8 4.2 155 7 156 165 2.1 0 2.3 1.8 12/24/2005 21:50:00 5 0.6 6.1 3.4 4.9 0.5 6.5 3.4 4.9 0.5 6.1 3.4 154 6 158 165 2 0 2.3 1.8 12/24/2005 22:00:00 4.7 0.6 6.1 3.4 4.7 0.5 6.1 3.4 4.7 0.5 6.1 3.8 154 7 153 165 2 0 2.3 1.8 12/24/2005 22:10:00 4.2 0.5 5.3 3 4.2 0.5 5.7 2.6 4 0.5 5.3 3 147 7 144 165 1.9 0 2.1 1.8 12/24/2005 22:20:00 4 0.6 5.7 3 4 0.6 5.7 2.6 4 0.5 5.7 2.3 147 6 148 165 1.9 0 1.8 1.8 12/24/2005 22:30:00 4 0.4 4.9 2.6 4 0.4 4.9 3 3.8 0.4 4.9 2.3 141 8 139 165 1.9 0 1.8 1.8 12/24/2005 22:40:00 3.5 0.5 4.9 2.3 3.5 0.5 4.9 2.3 3.4 0.5 4.6 2.6 137 7 140 165 1.9 0 1.8 1.8 12/24/2005 22:50:00 3.8 0.4 4.6 2.6 3.8 0.4 4.6 2.6 3.7 0.4 4.6 2.3 128 6 132 165 1.9 0 1.8 1.8 12/24/2005 23:00:00 4.3 0.5 5.3 3 4.3 0.5 5.7 2.6 4.2 0.5 5.7 3 132 4 133 165 1.9 0 2.1 1.8 12/24/2005 23:10:00 3.6 0.4 4.6 2.6 3.7 0.4 4.6 2.6 3.5 0.4 4.6 2.3 130 5 133 165 1.9 0 1.8 1.8 12/24/2005 23:20:00 5.4 1.1 7.2 3.4 5.6 1.1 7.6 3.4 5.5 1.3 7.6 2.6 120 9 121 165 1.9 0 2.1 1.8 12/24/2005 23:30:00 5.7 0.5 6.8 4.6 5.7 0.5 6.8 4.2 5.6 0.6 7.2 4.2 133 5 137 165 1.9 0 2.1 1.8 12/24/2005 23:40:00 6.2 0.5 8 4.6 6.2 0.5 8 4.9 6.1 0.7 7.6 4.2 127 9 135 165 1.9 0 1.8 1.8 12/24/2005 23:50:00 4.7 0.5 6.1 3.8 4.8 0.5 6.5 3.8 4.6 0.6 6.1 2.6 122 3 121 165 1.9 0 2.1 1.8 12/25/2005 00:00:00 5.9 0.6 7.2 4.2 6.1 0.6 7.6 4.6 5.8 0.7 7.2 3.8 120 4 117 165 2.1 0 2.3 1.8 12/25/2005 00:10:00 5.9 0.4 7.2 4.9 6.1 0.4 7.2 5.3 5.8 0.4 7.2 4.2 124 4 130 165 2.3 0 2.3 2.1 12/25/2005 00:20:00 6.1 0.7 8 4.6 6.2 0.7 8 3.8 5.9 0.8 8 3.8 128 8 139 165 2.3 0 2.3 2.3 12/25/2005 00:30:00 7.2 1 9.9 4.9 7.3 1 9.9 5.3 7.2 1 9.5 4.6 129 9 135 165 2 0 2.3 1.8 12/25/2005 00:40:00 5.5 0.5 7.2 4.2 5.5 0.5 6.8 3.8 5.3 0.6 6.8 3.8 135 8 136 165 2.2 0 2.3 2.1 12/25/2005 00:50:00 6.9 0.9 9.5 4.6 6.9 0.9 9.9 4.2 6.9 1 10.3 4.2 139 13 112 165 2.3 0 2.6 2.1 12/25/2005 01:00:00 7.5 0.8 9.5 5.3 7.5 0.9 9.1 5.3 7.4 0.9 9.9 4.6 130 8 123 165 2.5 0 2.6 2.3 12/25/2005 01:10:00 8 1.1 11.1 5.3 8.1 1.1 11.1 5.3 8 1.1 10.7 5.3 131 9 129 165 2.5 0 2.8 2.6 12/25/2005 01:20:00 8.9 1 11.1 6.5 8.9 1 11.1 6.5 8.9 1 10.7 6.5 137 7 140 165 2.4 0 2.6 2.3 12/25/2005 01:30:00 7.9 0.9 10.3 5.7 7.9 0.9 10.3 6.1 7.8 1 10.3 5.3 135 7 145 165 2.4 0 2.6 2.3 12/25/2005 01:40:00 9 0.6 10.7 7.2 9 0.6 10.7 7.2 8.9 0.6 10.7 7.2 142 5 142 165 2.3 0 2.6 2.3 12/25/2005 01:50:00 8.7 1 11.1 6.1 8.6 1 10.7 6.1 8.5 1 10.7 6.1 141 6 145 165 2.2 0 2.3 2.1 12/25/2005 02:00:00 7.4 0.9 9.5 5.3 7.5 0.9 9.9 5.7 7.3 1 9.5 4.2 133 9 143 165 2 0 2.3 1.8 12/25/2005 02:10:00 7.5 0.9 9.9 4.9 7.6 0.9 9.9 5.3 7.3 0.9 9.5 4.9 132 7 142 165 1.9 0 2.1 1.8 12/25/2005 02:20:00 6.9 0.9 9.5 4.9 7.1 0.9 9.5 5.3 6.7 0.9 8.8 3.8 124 6 129 165 2.1 0 2.3 1.8 12/25/2005 02:30:00 6.7 0.6 8.4 4.9 6.9 0.6 8.4 5.3 6.4 0.7 8 3.8 118 5 124 165 2.1 0 2.3 1.8 12/25/2005 02:40:00 7.3 0.7 9.1 5.7 7.5 0.8 9.5 5.7 7.1 0.8 9.1 4.6 112 5 99 165 2 0 2.3 1.8 12/25/2005 02:50:00 8.9 0.7 11.1 6.5 9.1 0.7 11.5 6.8 8.5 0.9 10.7 5.7 120 8 111 165 2 0 2.3 1.8 12/25/2005 03:00:00 8.8 1 11.5 5.7 9 1 11.5 6.1 8.4 1.1 11.1 5.7 114 6 114 165 2.2 0 2.3 1.8 12/25/2005 03:10:00 8.9 0.7 11.1 6.5 9.1 0.7 11.1 6.5 8.5 0.7 10.3 6.5 109 5 106 165 2.3 0 2.6 2.3 12/25/2005 03:20:00 8.6 0.8 10.7 6.5 8.8 0.8 10.7 6.8 8.3 0.9 10.3 6.1 107 4 106 165 2.4 0 2.6 2.3 12/25/2005 03:30:00 10.1 0.6 11.5 7.6 10.4 0.6 11.8 8 9.5 0.8 11.1 6.5 111 4 109 165 2.7 0 2.8 2.6 12/25/2005 03:40:00 8.9 0.5 10.3 7.2 9.2 0.5 10.7 7.6 8.4 0.7 10.3 5.3 107 3 110 165 2.8 0 2.8 2.8 12/25/2005 03:50:00 8.6 0.9 11.5 6.8 8.8 0.9 11.5 6.8 8.1 0.9 11.1 5.7 103 5 100 165 2.9 0 3 2.8 12/25/2005 04:00:00 8.9 1 11.1 6.1 9.1 1.1 11.5 5.7 8.2 1.1 11.1 5.3 96 6 94 165 3 0 3 2.8 12/25/2005 04:10:00 8.8 0.9 11.1 6.5 9 0.9 11.5 6.1 8.3 0.9 10.7 5.7 93 6 99 165 3 0 3 2.8 12/25/2005 04:20:00 9.4 1 11.5 5.7 9.6 1 11.8 6.1 8.7 1 11.1 6.5 93 6 94 165 3 0 3.3 3 12/25/2005 04:30:00 9 1 11.1 6.5 9.2 1 11.5 6.8 8.4 1 11.1 5.7 91 7 92 165 3.1 0 3.3 3 12/25/2005 04:40:00 10 1 12.2 7.2 10.3 1 12.6 7.6 9.4 1 11.8 6.8 95 6 98 165 3.1 0 3.3 3 12/25/2005 04:50:00 10.3 1 12.6 7.6 10.6 1.1 13 8 9.5 1.1 12.6 6.5 97 6 97 165 3.2 0 3.3 3 12/25/2005 05:00:00 10.1 1.2 12.6 6.8 10.3 1.2 13 6.8 9.5 1.2 12.6 6.5 93 7 99 165 3.2 0 3.3 3.3 12/25/2005 05:10:00 10.6 1.3 13.3 6.5 10.8 1.3 13.7 7.2 9.9 1.3 13 6.1 88 6 92 165 3.2 0 3.3 3.3 12/25/2005 05:20:00 10.4 1.1 13.7 7.2 10.6 1.2 14.5 7.2 9.8 1.2 13 6.5 89 7 88 165 3.3 0 3.5 3.3 12/25/2005 05:30:00 11 1.2 13.7 7.6 11.3 1.2 13.7 8 10.4 1.2 13.3 6.8 92 7 95 165 3.3 0 3.5 3.3 12/25/2005 05:40:00 10.7 1.2 14.1 7.6 11 1.2 14.1 7.6 10.2 1.2 13.7 6.8 90 7 87 165 3.4 0 3.5 3.3 12/25/2005 05:50:00 11.2 1.2 13.7 8.4 11.5 1.2 14.1 8 10.6 1.2 13 6.8 87 7 94 165 3.4 0 3.5 3.3 12/25/2005 06:00:00 11.7 1.5 15.3 7.6 12 1.5 15.6 8 11.2 1.4 14.5 7.2 91 7 87 165 3.5 0 3.5 3.5 12/25/2005 06:10:00 11.6 1.4 15.3 6.8 11.8 1.4 15.3 6.8 10.9 1.5 14.9 7.2 93 8 96 165 3.5 0 3.5 3.3 12/25/2005 06:20:00 12.5 1.6 15.6 8 12.8 1.7 16.1 8.8 11.8 1.7 15.6 7.2 92 8 89 165 3.6 0 3.8 3.5 12/25/2005 06:30:00 12.7 1.7 16.4 7.6 13 1.7 17.2 7.6 11.8 1.7 15.6 7.6 94 7 80 165 3.5 0 3.8 3.3 12/25/2005 06:40:00 12.6 1.5 16.1 8.8 12.8 1.5 16.1 8.4 11.9 1.5 15.3 8 91 7 93 165 3.5 0 3.5 3.3 12/25/2005 06:50:00 13.2 1.5 16.8 8.8 13.6 1.5 16.8 9.1 12.6 1.5 16.1 8.8 88 7 84 165 3.5 0 3.5 3.5 12/25/2005 07:00:00 12.7 1.8 16.4 8 12.9 1.9 16.8 9.1 11.9 1.8 16.1 7.2 89 8 90 165 3.6 0 3.5 3.5 12/25/2005 07:10:00 13.2 1.4 16.8 9.1 13.5 1.5 17.6 9.5 12.6 1.5 16.8 9.1 88 6 91 165 3.6 0 3.8 3.5 12/25/2005 07:20:00 14.1 1.6 17.2 9.5 14.4 1.6 17.6 9.5 13.4 1.7 18.7 8.8 90 8 90 165 3.6 0 3.5 3.5 12/25/2005 07:30:00 13.4 1.6 17.2 8.8 13.7 1.6 17.9 9.5 12.5 1.5 17.2 8 90 8 81 165 3.6 0 3.8 3.5 12/25/2005 07:40:00 13.4 1.8 18.3 8 13.7 1.9 18.7 8.4 12.6 1.7 16.8 7.6 88 9 93 165 3.6 0 3.8 3.5 12/25/2005 07:50:00 14 1.7 17.9 9.1 14.3 1.7 18.3 8.8 13.2 1.6 17.2 8 89 7 84 165 3.6 0 3.8 3.5 12/25/2005 08:00:00 14.1 1.6 17.9 9.9 14.4 1.7 18.3 9.9 13.4 1.8 17.2 8.4 87 7 85 165 3.6 0 3.8 3.5 12/25/2005 08:10:00 14.5 1.5 18.3 10.7 14.9 1.6 19.1 11.1 13.9 1.5 19.1 9.9 88 7 86 165 3.7 0 3.8 3.5 12/25/2005 08:20:00 14.8 1.7 18.7 9.5 15.1 1.7 19.5 9.5 13.9 1.7 17.9 9.5 90 7 96 165 3.8 0 4 3.8 12/25/2005 08:30:00 14.4 2.3 19.5 9.5 14.7 2.4 20.2 9.5 13.4 2.2 19.1 9.5 92 8 92 165 3.9 0 4 3.8 12/25/2005 08:40:00 14.7 2 19.5 8.4 15 2 19.5 8.8 13.6 2.2 19.5 8.4 95 7 93 165 3.9 0 4 3.8 12/25/2005 08:50:00 15.8 2.1 21 10.3 16.1 2.1 21 9.9 14.6 2 19.5 8.8 97 7 105 165 4 0 4 3.8 12/25/2005 09:00:00 15 1.7 19.1 10.3 15.3 1.7 19.9 10.3 14.1 1.8 18.3 9.5 98 7 103 165 4 0 4.3 3.8 12/25/2005 09:10:00 15.8 1.7 19.9 11.1 16 1.7 20.2 11.1 14.7 1.7 19.5 10.7 99 7 98 165 4 0 4.3 4 12/25/2005 09:20:00 15.4 1.5 19.5 10.7 15.7 1.6 19.5 11.5 14.5 1.8 19.1 8.4 98 7 92 165 4.1 0 4.3 4 12/25/2005 09:30:00 15.1 1.8 19.1 9.5 15.4 1.9 19.1 9.1 14.1 2.1 18.3 8.8 95 7 96 165 4.1 0 4.3 4 12/25/2005 09:40:00 15.6 1.6 19.1 10.3 15.8 1.7 19.1 10.3 14.2 1.9 17.9 9.5 97 7 88 165 4.1 0 4.3 4.3 12/25/2005 09:50:00 15.3 1.7 19.5 11.1 15.6 1.7 19.9 11.1 14.2 1.7 18.7 9.5 98 6 100 165 4.4 0 4.5 4.3 12/25/2005 10:00:00 14.9 1.5 19.5 10.3 15.1 1.5 19.5 9.9 13.8 1.5 18.3 9.5 103 6 108 165 4.6 0 4.8 4.5 12/25/2005 10:10:00 15.7 1.4 18.3 11.1 16 1.4 19.1 11.8 14.6 1.6 18.3 9.9 107 6 108 165 4.8 0 5 4.8 12/25/2005 10:20:00 16.7 1.4 20.2 12.6 17 1.4 20.2 13 15.8 1.7 20.2 11.1 111 6 107 165 4.9 0 5 4.8 12/25/2005 10:30:00 13.4 1.5 17.9 9.5 13.6 1.5 18.3 9.5 12.7 1.6 16.8 8.4 115 7 102 165 4.9 0 5 5 12/25/2005 10:40:00 12.9 1.2 16.4 9.1 13.1 1.3 16.8 9.5 12.2 1.4 16.4 7.6 114 7 112 165 5 0 5 5 12/25/2005 10:50:00 13.1 1.3 16.4 9.9 13.3 1.3 16.4 9.9 12.4 1.5 16.4 7.6 116 7 112 165 5 0 5.2 5 12/25/2005 11:00:00 12.8 1.3 17.2 9.1 13.1 1.3 16.8 9.5 12.3 1.3 16.4 8.8 118 6 116 165 4.9 0 5 4.8 12/25/2005 11:10:00 12.7 1.5 16.1 8.4 12.9 1.5 16.1 8.8 12.2 1.6 16.1 8.4 120 6 121 165 4.9 0 5 4.8 12/25/2005 11:20:00 12.1 1.6 16.8 8.4 12.4 1.6 17.2 8.4 11.7 1.7 16.1 8 119 6 119 165 4.9 0 5 4.8 12/25/2005 11:30:00 11.8 1.3 14.9 8 12 1.3 14.9 8 11.5 1.5 14.5 7.2 120 6 121 165 4.9 0 5 4.8 12/25/2005 11:40:00 10.9 1.5 15.3 7.2 11.1 1.4 15.3 7.6 10.5 1.3 14.9 7.2 119 6 119 165 5 0 5 5 12/25/2005 11:50:00 10.3 1.2 14.1 7.2 10.6 1.2 14.9 7.2 9.8 1.2 12.6 6.1 115 7 116 165 5 0 5 5 12/25/2005 12:00:00 9.9 1.2 12.6 6.1 10.1 1.2 13 6.5 9.5 1.2 13 6.8 115 6 114 165 4.8 0 5 4.8 12/25/2005 12:10:00 9.4 1 11.8 6.5 9.6 1 11.8 6.8 9 0.9 11.1 6.5 116 6 112 165 4.7 0 4.8 4.8 12/25/2005 12:20:00 9.9 0.9 12.6 8 10.2 0.9 12.6 7.6 9.5 1 13 6.8 114 7 103 165 4.6 0 4.8 4.5 12/25/2005 12:30:00 10.8 1.1 14.1 6.8 11.1 1.1 13.7 7.6 10.2 1.2 13 5.7 116 5 107 165 4.6 0 4.8 4.5 12/25/2005 12:40:00 10.8 0.8 13.7 8 11.1 0.9 13.7 7.6 10.4 1 13.3 7.2 116 6 119 165 4.8 0 5 4.8 12/25/2005 12:50:00 10.8 1.1 14.9 8.8 11 1.1 14.9 9.1 10.4 1.2 15.3 8 116 6 128 165 4.8 0 5 4.8 12/25/2005 13:00:00 11.5 1.3 14.5 8.4 11.8 1.2 14.9 8.8 11.5 1.3 15.3 8 122 8 110 165 4.5 0 4.8 4.3 12/25/2005 13:10:00 9.6 1 11.5 7.6 9.8 1 11.8 7.6 9.5 0.8 11.5 7.2 124 5 121 165 4.4 0 4.5 4.3 12/25/2005 13:20:00 9.1 0.9 12.2 7.2 9.3 0.9 12.6 7.2 8.7 1 11.8 6.5 118 6 121 165 4.3 0 4.5 4.3 12/25/2005 13:30:00 10.3 1.2 13.7 7.2 10.6 1.2 14.5 6.8 9.7 1.3 13.3 6.5 111 7 109 165 4.5 0 4.8 4.5 12/25/2005 13:40:00 10.9 1.1 13.7 7.6 11.2 1.1 14.1 7.6 10.2 1.2 12.6 6.8 103 6 99 165 4.5 0 4.8 4.3 12/25/2005 13:50:00 10.1 1 13 6.1 10.3 1 13.3 6.5 9.6 1.1 12.6 6.1 110 8 112 165 4.3 0 4.5 4.3 12/25/2005 14:00:00 11.2 1.1 13.3 8 11.4 1.2 13.7 8.4 10.7 1.4 14.1 6.8 118 6 108 165 4.1 0 4.3 4 12/25/2005 14:10:00 10.7 1.2 14.1 8 10.9 1.2 14.9 8.4 10.4 1.3 15.3 7.6 125 8 126 165 4.1 0 4.3 4 12/25/2005 14:20:00 8.6 1.1 11.5 5.7 8.8 1.1 11.8 6.1 8.5 1.2 11.1 4.9 123 7 121 165 4.1 0 4.3 4.3 12/25/2005 14:30:00 11.2 2.9 17.9 6.5 11.4 2.9 18.3 6.8 10.6 2.8 17.6 6.1 115 9 104 165 4.4 0.1 4.8 4.3 12/25/2005 14:40:00 11.4 1.7 16.8 8 11.6 1.7 16.4 8 11.2 1.6 15.3 7.2 134 10 142 165 4.4 0.2 4.8 4.3 12/25/2005 14:50:00 12.1 1.5 15.6 8.8 12.2 1.5 16.4 8.8 11.9 1.5 17.2 8.4 128 7 122 165 4.1 0 4.3 4 12/25/2005 15:00:00 11.5 1.5 15.6 8.4 11.6 1.5 16.1 8 11.2 1.7 16.4 7.2 124 9 121 165 4 0 4.3 3.8 12/25/2005 15:10:00 11.8 1.7 16.4 7.6 12 1.7 16.8 8 11.4 1.7 16.4 8.4 123 11 135 165 3.8 0 4 3.5 12/25/2005 15:20:00 10.8 1.3 13.7 6.8 11 1.3 14.5 7.2 10.4 1.3 13.3 6.8 127 9 122 165 3.6 0 3.8 3.5 12/25/2005 15:30:00 11 1.7 15.3 6.1 11.2 1.7 15.6 5.3 10.3 1.7 14.9 5.3 109 9 104 165 3.6 0 3.8 3.5 12/25/2005 15:40:00 13 1.4 16.1 8.8 13.2 1.4 16.4 8.8 12.2 1.5 16.4 8 104 6 98 165 3.9 0 4 3.8 12/25/2005 15:50:00 14 1.4 17.9 10.3 14.3 1.5 18.3 10.3 13.2 1.6 17.6 8.8 104 6 105 165 4.1 0 4.5 4 12/25/2005 16:00:00 14.1 1.7 18.3 9.1 14.5 1.7 18.7 9.1 13.2 1.8 17.6 8.8 102 7 94 165 4.4 0 4.5 4.3 12/25/2005 16:10:00 14.1 1.1 17.2 10.3 14.4 1.1 17.2 10.3 13.2 1.3 16.4 8.4 104 6 106 165 4.4 0 4.5 4.3 12/25/2005 16:20:00 13.8 1.6 18.3 8.8 14 1.7 18.7 8.4 12.8 1.7 16.1 7.6 104 6 102 165 4.4 0 4.5 4.3 12/25/2005 16:30:00 15 1.4 17.9 11.1 15.3 1.4 18.3 11.8 14.3 1.7 17.9 9.9 104 6 94 165 4.3 0 4.5 4.3 12/25/2005 16:40:00 13.8 1.7 17.6 9.1 14 1.7 17.9 9.5 12.9 1.7 16.8 8.4 102 6 102 165 4.1 0 4.3 4 12/25/2005 16:50:00 14.2 1.4 17.6 9.9 14.4 1.4 17.9 8.8 13.2 1.5 16.8 9.5 107 7 99 165 4.1 0 4.3 4 12/25/2005 17:00:00 13.1 1.2 16.1 8.4 13.3 1.3 16.8 8.4 12.5 1.5 15.6 8.4 116 6 121 165 4.4 0 4.5 4.3 12/25/2005 17:10:00 12.8 1.3 15.6 9.9 13 1.3 16.1 10.3 12.4 1.4 15.6 8 118 6 115 165 4.6 0 4.8 4.5 12/25/2005 17:20:00 12.6 1.4 16.1 9.1 12.8 1.4 16.4 9.1 11.8 1.6 16.4 8.4 117 6 116 165 4.7 0 4.8 4.8 12/25/2005 17:30:00 11.5 1.3 15.3 7.6 11.7 1.4 15.6 7.6 11 1.5 15.6 7.2 114 7 108 165 4.7 0 4.8 4.5 12/25/2005 17:40:00 12.7 1.1 15.3 9.1 13 1.1 15.6 9.5 12.2 1.3 15.3 8 108 6 114 165 4.7 0 4.8 4.5 12/25/2005 17:50:00 13 1.2 15.6 8.8 13.2 1.3 16.1 8.4 12.1 1.5 15.6 8 101 6 101 165 4.6 0 4.8 4.5 12/25/2005 18:00:00 12.3 1.3 15.6 8.8 12.6 1.3 16.1 8.8 11.5 1.3 15.3 8.4 99 6 98 165 4.6 0 4.8 4.5 12/25/2005 18:10:00 13.3 1.1 15.6 9.1 13.6 1.1 16.4 9.1 12.5 1.2 15.3 8.4 101 6 94 165 4.6 0 4.8 4.5 12/25/2005 18:20:00 13.2 1.3 16.1 9.1 13.5 1.3 16.8 9.1 12.3 1.5 15.6 8.4 99 7 102 165 4.7 0 4.8 4.5 12/25/2005 18:30:00 13.9 1.7 18.3 7.2 14.2 1.8 18.7 7.6 13 1.9 18.7 7.6 97 6 94 165 4.7 0 5 4.8 12/25/2005 18:40:00 14.8 1.5 19.1 9.5 15.1 1.6 19.1 9.9 13.8 1.7 19.1 9.1 102 7 105 165 4.8 0 5 4.8 12/25/2005 18:50:00 14.6 1.9 18.7 8.8 14.9 1.9 19.5 8.8 14 1.9 18.7 9.5 107 7 109 165 4.8 0 5 4.5 12/25/2005 19:00:00 13.3 1.4 16.8 8.8 13.5 1.4 17.2 8.8 12.4 1.7 16.1 8 107 6 109 165 4.6 0 4.8 4.5 12/25/2005 19:10:00 13.7 1.6 17.6 9.5 13.9 1.7 17.9 9.5 12.6 1.7 16.8 8.8 100 9 99 165 4.6 0 4.8 4.5 12/25/2005 19:20:00 14.8 1.7 18.3 9.9 15.1 1.7 18.7 9.9 14 1.8 17.9 9.5 108 7 97 165 4.6 0 4.8 4.5 12/25/2005 19:30:00 15.6 2.1 20.2 9.9 15.9 2.2 21.4 10.3 14.8 2.2 19.1 9.1 113 7 104 165 4.5 0 4.8 4.5 12/25/2005 19:40:00 12.9 1.5 16.8 9.1 13.1 1.5 17.6 9.1 12.2 1.7 16.4 7.2 117 7 120 165 4.5 0 4.5 4.5 12/25/2005 19:50:00 13.1 1.3 16.8 8.8 13.4 1.3 17.2 9.1 12.9 1.4 16.8 8 124 7 122 165 4.5 0 4.8 4.5 12/25/2005 20:00:00 14.9 2.1 19.1 11.1 15.1 2.1 19.5 11.1 14.5 2.3 19.9 9.1 126 7 125 165 4.5 0 4.8 4.5 12/25/2005 20:10:00 13.6 1.6 17.9 9.5 13.8 1.7 17.9 9.9 13.3 1.6 17.2 9.5 127 6 128 165 4.4 0 4.5 4.5 12/25/2005 20:20:00 13.6 1.5 17.9 9.9 13.7 1.5 18.3 9.9 13.3 1.7 18.3 9.5 128 8 117 165 4.4 0 4.5 4.5 12/25/2005 20:30:00 13.8 1.4 16.8 9.5 13.9 1.5 17.2 8.8 13.4 1.5 16.8 9.9 130 8 130 165 4.4 0 4.5 4.3 12/25/2005 20:40:00 13 1.2 16.8 9.9 13.1 1.2 16.8 10.3 12.5 1.4 15.6 8.8 127 7 122 165 4.4 0 4.5 4.3 12/25/2005 20:50:00 14.4 1.2 17.6 10.7 14.5 1.2 17.6 10.7 14.2 1.2 17.2 10.3 130 8 130 165 4.4 0 4.5 4.3 12/25/2005 21:00:00 13.4 1.3 17.2 9.9 13.6 1.3 17.6 9.5 13 1.3 16.8 9.5 134 6 145 165 4.4 0 4.5 4.3 12/25/2005 21:10:00 12.8 1.2 15.6 9.5 12.9 1.2 16.1 8.8 12.5 1.3 16.4 9.1 136 7 137 165 4.4 0 4.5 4.3 12/25/2005 21:20:00 13.1 1.7 17.2 8.8 13.2 1.7 17.9 8.8 12.9 1.7 16.4 8.8 135 7 143 165 4.1 0.1 4.5 4.3 12/25/2005 21:30:00 12.2 1.1 15.3 9.5 12.3 1.1 15.3 9.5 12.1 1.1 15.6 9.5 137 7 134 165 4.2 0 4.3 4.3 12/25/2005 21:40:00 10.8 1 13.3 7.2 10.8 1 13.7 7.6 10.5 1.1 13.3 6.5 135 7 144 165 4.2 0 4.5 4.3 12/25/2005 21:50:00 10.6 1.2 14.1 8.4 10.7 1.2 13.7 8 10.4 1.2 13.3 7.6 139 7 132 165 4.3 0 4.5 4.3 12/25/2005 22:00:00 13 1.3 15.3 9.5 13.1 1.3 15.6 9.1 12.8 1.5 16.1 8.4 137 7 133 165 4.2 0 4.5 4.3 12/25/2005 22:10:00 13.2 1.2 16.1 10.3 13.3 1.2 16.4 10.3 13.2 1.2 16.4 9.5 142 6 133 165 4.1 0 4.3 4 12/25/2005 22:20:00 13.7 0.9 16.1 11.5 13.7 0.9 16.1 11.5 13.7 1 16.1 10.7 144 5 143 165 4.1 0 4.3 4.3 12/25/2005 22:30:00 14.1 1 16.4 11.8 14.2 1 16.4 11.8 14 1.1 16.8 9.9 146 4 149 165 4.1 0 4.3 4.3 12/25/2005 22:40:00 13 0.8 15.6 11.1 13 0.8 15.6 11.1 12.7 0.9 15.6 10.7 148 4 158 165 4.1 0 4.3 4 12/25/2005 22:50:00 11.2 0.8 13 9.1 11.3 0.8 13 9.5 10.9 0.8 13 8.4 146 3 144 165 4 0 4.3 4 12/25/2005 23:00:00 12.3 1 15.3 9.5 12.5 1 15.3 9.1 12.1 1.1 14.5 9.1 147 4 149 165 4 0 4.3 3.8 12/25/2005 23:10:00 11.6 0.8 13.7 9.5 11.6 0.8 13.7 9.1 11.5 0.9 13.3 8.8 148 4 144 165 3.8 0 4 3.8 12/25/2005 23:20:00 11.5 0.6 13.3 9.9 11.6 0.6 13.7 9.9 11.3 0.7 13 9.1 148 3 145 165 3.8 0 3.8 3.8 12/25/2005 23:30:00 10.5 0.7 12.2 8 10.7 0.7 12.2 8.4 10.5 0.8 12.2 7.6 148 4 150 165 3.8 0 3.8 3.5 12/25/2005 23:40:00 10.7 0.5 11.8 9.1 10.9 0.5 11.8 9.1 10.7 0.6 12.2 9.1 149 3 154 165 3.7 0 3.8 3.5 12/25/2005 23:50:00 10.6 0.7 13 9.1 10.8 0.6 13 9.5 10.6 0.7 13 9.1 148 3 147 165 3.7 0 3.8 3.5 12/26/2005 00:00:00 11.1 0.6 12.6 9.1 11.3 0.6 12.6 9.5 11 0.8 12.6 8.4 148 4 151 165 3.9 0 4 3.8 12/26/2005 00:10:00 12.9 1.5 16.8 9.9 13 1.5 16.8 10.3 12.8 1.5 16.8 9.9 145 4 143 165 4.1 0 4.3 4 12/26/2005 00:20:00 14.8 0.8 16.4 12.6 14.9 0.9 16.8 12.6 14.6 1.2 17.6 10.7 145 4 148 165 4 0.1 4.5 3.8 12/26/2005 00:30:00 14.1 1 16.1 11.5 14.1 0.9 16.1 11.1 13.8 1 16.1 10.3 142 5 139 165 3.6 0.1 3.8 3.5 12/26/2005 00:40:00 13.9 0.9 15.6 11.1 14 0.9 16.1 11.5 13.9 1 16.8 11.5 145 4 141 165 3.3 0 3.5 3.3 12/26/2005 00:50:00 12.4 0.8 14.5 10.3 12.5 0.9 15.3 9.9 12.3 1 14.9 9.9 146 4 146 165 3.5 0.1 3.8 3.3 12/26/2005 01:00:00 13.1 1.1 16.8 11.1 13.2 1.1 16.8 11.1 13 1.1 16.8 10.3 143 4 146 165 3.8 0 4 3.8 12/26/2005 01:10:00 12.6 1.8 17.9 10.3 12.6 1.8 18.3 10.3 12.6 2.1 17.9 9.9 152 6 152 165 3.4 0.2 4 3.3 12/26/2005 01:20:00 10.7 0.7 12.2 8.8 10.8 0.7 12.2 8.8 10.7 0.8 12.2 7.6 149 3 147 165 3.4 0 3.5 3.3 12/26/2005 01:30:00 10.3 0.6 12.2 8.4 10.4 0.6 11.8 9.1 10.2 0.7 11.5 7.6 147 4 145 165 3.5 0 3.5 3.5 12/26/2005 01:40:00 10.1 0.9 12.2 8.4 10.2 0.9 12.2 8.4 10.1 0.9 12.6 8 149 4 152 165 3.6 0 3.8 3.5 12/26/2005 01:50:00 10.1 0.7 12.2 8.4 10.3 0.7 12.2 8.8 10 0.7 12.2 8 147 4 151 165 3.7 0 4 3.5 12/26/2005 02:00:00 11.6 1.3 14.1 8.8 11.6 1.3 14.1 9.1 11.3 1.3 14.1 8.4 146 5 152 165 4 0.1 4.3 3.8 12/26/2005 02:10:00 11.3 0.6 13.3 9.9 11.4 0.5 13.3 9.9 11.2 0.6 13 9.1 148 3 145 165 4.1 0 4.3 4.3 12/26/2005 02:20:00 11.1 0.6 13 9.1 11.2 0.6 13 9.1 10.9 0.7 12.2 8.8 145 4 148 165 4.1 0 4.3 4.3 12/26/2005 02:30:00 11.5 0.8 13.3 9.1 11.5 0.8 13.7 9.1 11.3 0.9 13.3 8.8 143 5 148 165 4.1 0 4.5 4.3 12/26/2005 02:40:00 12.2 0.9 14.1 9.9 12.3 1 14.5 9.5 12.1 1.1 14.5 8 140 6 135 165 4.1 0 4.3 4.3 12/26/2005 02:50:00 11.2 1 14.5 7.6 11.3 1 14.5 8 11.1 1 13.3 8 139 6 135 165 4.1 0 4.3 4 12/26/2005 03:00:00 10.8 1.1 13.7 8 10.9 1.1 14.1 8 10.7 1.2 13.7 6.8 137 7 139 165 3.9 0.1 4.3 3.5 12/26/2005 03:10:00 11.3 1 14.5 8.8 11.4 1 14.1 9.1 11.2 1 14.1 8.8 137 7 139 165 3.5 0 3.8 3.5 12/26/2005 03:20:00 11.6 1 14.1 8.8 11.7 1 14.5 8.4 11.2 1 13.7 8.8 138 8 137 165 3.6 0 3.5 3.5 12/26/2005 03:30:00 11.8 1.9 16.1 8 12 1.9 16.1 8.4 11.8 2 16.1 8 138 6 135 165 3.6 0 3.8 3.5 12/26/2005 03:40:00 11.7 1.2 15.3 8.8 11.9 1.2 14.9 8.8 11.6 1.3 14.9 8.4 133 7 123 165 3.4 0 3.5 3.3 12/26/2005 03:50:00 10.2 1 13 7.2 10.4 1 13 7.6 10.2 1 13 6.5 127 7 128 165 3.2 0 3.3 3 12/26/2005 04:00:00 8.8 0.8 11.1 6.5 8.9 0.8 11.1 6.5 8.7 0.8 10.7 5.7 122 7 121 165 3.3 0.1 3.5 3 12/26/2005 04:10:00 9.1 0.8 11.5 6.8 9.3 0.8 11.8 6.8 8.8 0.8 10.7 6.8 115 6 117 165 3.7 0 3.8 3.5 12/26/2005 04:20:00 9.8 0.9 11.8 8 10 0.8 12.2 7.6 9.4 0.8 11.5 6.8 117 7 111 165 3.9 0 4 3.8 12/26/2005 04:30:00 9.3 1.4 13.7 6.8 9.5 1.4 14.1 6.8 8.8 1.5 14.1 5.7 116 7 108 165 3.9 0 4 3.8 12/26/2005 04:40:00 9.1 1.1 11.8 6.1 9.3 1.1 11.8 6.1 8.7 1.2 12.2 6.1 121 8 121 165 3.8 0 4 3.8 12/26/2005 04:50:00 9.7 1.3 13 6.8 9.9 1.3 13.3 6.8 9.3 1.4 13.3 6.1 118 7 119 165 3.8 0 3.8 3.8 12/26/2005 05:00:00 10.7 1.5 13.7 6.5 11 1.5 14.1 5.7 10.4 1.7 13.3 5.3 114 8 112 165 3.8 0 4 3.5 12/26/2005 05:10:00 9.9 1 13.3 7.6 10.1 1 13 7.6 9.5 1.2 12.6 6.5 115 6 107 165 3.5 0 3.8 3.3 12/26/2005 05:20:00 7.7 0.9 9.9 4.9 7.9 0.9 10.3 5.7 7.3 1 9.9 4.6 114 6 114 165 3.5 0 3.5 3.3 12/26/2005 05:30:00 8.6 0.8 10.7 5.7 8.8 0.8 10.3 5.7 8.1 1 9.9 4.9 108 5 108 165 3.6 0 3.8 3.5 12/26/2005 05:40:00 8.5 1 10.7 5.3 8.7 1 11.5 5.3 7.9 1 10.3 3.8 104 9 97 165 3.8 0 3.8 3.5 12/26/2005 05:50:00 8.9 1 10.7 6.1 9.1 1 11.1 6.1 8.4 1.1 10.7 5.7 107 6 106 165 3.9 0 4 3.8 12/26/2005 06:00:00 7.5 0.8 9.1 4.9 7.7 0.8 9.1 5.3 7.1 0.9 9.5 4.9 111 6 105 165 3.8 0 4 3.5 12/26/2005 06:10:00 7.3 0.5 8.4 5.7 7.5 0.5 8.8 5.7 7.1 0.7 9.1 4.9 113 4 116 165 3.8 0 3.8 3.5 12/26/2005 06:20:00 7.2 0.5 8.8 5.7 7.4 0.5 8.8 5.7 7 0.6 8.8 4.6 114 5 121 165 3.9 0 4 3.8 12/26/2005 06:30:00 7.5 0.6 9.5 6.5 7.8 0.6 9.9 6.5 7.2 0.6 9.5 5.3 111 5 115 165 4 0 4.3 3.8 12/26/2005 06:40:00 10.5 1.6 14.5 6.8 10.7 1.6 15.3 6.8 10.3 1.9 16.1 6.1 114 12 97 165 3.9 0.2 4.3 3.5 12/26/2005 06:50:00 9 1.1 12.2 6.1 9.1 1.1 11.8 6.1 8.7 1.2 11.8 5.7 129 10 134 165 3.8 0 4 3.5 12/26/2005 07:00:00 8.2 0.5 9.5 6.8 8.5 0.5 9.9 6.8 8 0.7 10.3 5.7 115 4 119 165 3.8 0 4 3.5 12/26/2005 07:10:00 8.1 0.5 9.9 6.5 8.4 0.5 9.9 6.8 8 0.6 9.5 6.1 114 6 114 165 3.6 0 3.8 3.5 12/26/2005 07:20:00 8.9 0.6 10.3 6.8 9.2 0.6 10.7 7.2 8.7 0.7 10.3 6.5 113 4 106 165 3.8 0 4 3.8 12/26/2005 07:30:00 8.8 0.6 10.3 6.8 9 0.6 10.3 6.8 8.3 0.8 10.3 6.1 113 5 106 165 4 0 4.3 3.8 12/26/2005 07:40:00 9.3 0.6 11.1 7.6 9.5 0.6 11.5 8 9 0.8 11.1 6.1 110 5 103 165 4.1 0 4.3 3.8 12/26/2005 07:50:00 8.7 0.7 10.7 6.8 8.9 0.7 10.7 7.2 8.3 0.9 11.1 4.9 108 7 108 165 4 0 4 3.8 12/26/2005 08:00:00 9.3 0.8 12.2 6.8 9.5 0.8 11.8 6.1 8.6 1 10.7 5.7 101 6 106 165 4 0 4.3 4 12/26/2005 08:10:00 9.7 0.8 11.5 7.6 9.9 0.8 11.8 7.6 9.2 0.9 11.5 6.8 103 5 110 165 4 0 4.3 3.8 12/26/2005 08:20:00 9.9 0.5 11.1 8 10.1 0.5 11.5 8.4 9.5 0.7 10.7 6.5 106 4 111 165 3.5 0 3.8 3.5 12/26/2005 08:30:00 9.9 0.7 11.5 7.2 10.1 0.7 11.8 7.6 9.2 0.9 11.1 6.8 101 4 100 165 3.6 0 3.8 3.3 12/26/2005 08:40:00 9.8 0.8 11.8 7.6 10 0.9 11.8 7.6 9.2 1 11.1 6.1 102 6 97 165 3.8 0 4 3.8 12/26/2005 08:50:00 9.9 0.5 11.5 8.4 10.1 0.6 12.2 8.8 9.5 0.7 11.1 7.2 110 4 116 165 3.6 0 3.8 3.5 12/26/2005 09:00:00 10.2 0.8 12.2 7.6 10.4 0.8 12.2 7.6 9.6 1 12.2 6.1 112 5 113 165 3.6 0 3.8 3.5 12/26/2005 09:10:00 10.1 0.8 12.2 7.6 10.4 0.8 12.6 8 9.7 1 11.8 7.2 108 4 110 165 3.7 0 3.8 3.5 12/26/2005 09:20:00 11 0.7 12.6 8.4 11.2 0.7 13 8 10.5 0.9 12.6 7.2 111 4 116 165 4 0 4 3.8 12/26/2005 09:30:00 10.8 0.7 12.6 9.1 11 0.7 13 9.1 10.2 0.9 12.6 7.6 110 4 112 165 4 0 4.3 3.8 12/26/2005 09:40:00 11 0.9 13.3 7.6 11.2 1 13.7 7.6 10.7 1.2 13.3 6.8 116 9 114 165 4 0 4.3 3.8 12/26/2005 09:50:00 11.4 1 13.7 9.1 11.5 1 13.7 9.5 11.2 1 13.7 8 129 6 133 165 3.9 0 4.3 3.5 12/26/2005 10:00:00 10 1.3 13 7.2 10.2 1.3 13 7.2 9.8 1.3 12.6 6.5 124 7 125 165 3.7 0 3.8 3.5 12/26/2005 10:10:00 10.4 1 13 8 10.6 1 13 8 10.2 1.1 13.7 7.6 120 5 121 165 3.8 0 3.8 3.5 12/26/2005 10:20:00 10 1.1 13 7.2 10.2 1.1 13.3 7.6 9.6 1.1 13.7 6.8 116 7 107 165 3.6 0 3.8 3.5 12/26/2005 10:30:00 9.1 0.8 11.1 7.2 9.3 0.8 11.1 7.2 8.8 0.9 11.8 6.1 117 5 118 165 3.6 0 3.8 3.5 12/26/2005 10:40:00 9.3 0.7 11.1 7.6 9.5 0.7 11.5 7.6 9.1 0.9 11.1 5.7 116 5 115 165 3.8 0 3.8 3.5 12/26/2005 10:50:00 10.3 1.7 15.6 6.1 10.6 1.6 16.4 6.1 9.9 1.6 15.6 5.7 116 7 121 165 3.8 0 3.8 3.8 12/26/2005 11:00:00 10.9 1.1 14.5 8.4 11.1 1.1 14.5 8.4 10.6 1.2 13.7 6.1 129 9 121 165 3.5 0 3.8 3.3 12/26/2005 11:10:00 9.4 1.2 12.2 6.5 9.5 1.2 12.2 6.5 9 1.2 12.2 5.7 128 9 140 165 3.1 0.1 3.5 3 12/26/2005 11:20:00 8.3 0.7 10.3 6.1 8.5 0.7 10.7 6.5 8.1 0.7 9.9 5.3 120 5 119 165 3.2 0 3.3 3 12/26/2005 11:30:00 8.5 0.9 10.7 5.7 8.6 0.9 11.1 6.1 8.3 0.9 11.1 5.7 125 5 139 165 3.3 0 3.5 3.3 12/26/2005 11:40:00 9.7 0.8 11.5 6.8 9.8 0.8 11.5 7.2 9.4 0.9 11.5 6.8 128 7 129 165 3.5 0 3.5 3.5 12/26/2005 11:50:00 8.9 0.8 11.1 6.8 9.1 0.8 11.5 7.2 8.8 0.9 11.1 6.5 125 6 121 165 3.6 0 3.8 3.5 12/26/2005 12:00:00 7.7 0.7 10.3 6.1 7.9 0.7 9.9 6.1 7.5 0.8 9.9 4.9 117 6 112 165 3.8 0 3.8 3.5 12/26/2005 12:10:00 8.3 1 12.2 6.5 8.5 1 11.8 6.5 7.9 1 11.5 5.7 116 7 111 165 3.8 0 4 3.8 12/26/2005 12:20:00 7.5 0.8 9.1 4.2 7.7 0.8 9.5 4.6 7.4 0.8 9.5 4.6 113 6 106 165 3.6 0 3.8 3.5 12/26/2005 12:30:00 8.3 0.8 10.7 6.1 8.5 0.8 10.7 6.5 8 0.8 10.3 6.1 117 6 119 165 3.6 0 3.8 3.5 12/26/2005 12:40:00 8.8 0.8 10.7 6.8 9 0.8 11.1 7.2 8.7 0.8 11.1 6.8 124 6 121 165 3.7 0 3.8 3.5 12/26/2005 12:50:00 8.5 0.7 10.7 6.8 8.6 0.7 10.7 6.8 8.3 0.8 11.1 5.7 123 7 121 165 3.8 0 4 3.8 12/26/2005 13:00:00 7.7 0.7 9.5 5.7 7.9 0.7 9.9 5.7 7.7 0.6 9.5 6.1 120 5 122 165 3.8 0 4 3.8 12/26/2005 13:10:00 7.5 0.7 9.9 5.7 7.7 0.7 9.9 6.1 7.5 0.7 9.5 5.3 120 5 119 165 3.9 0 4 3.8 12/26/2005 13:20:00 7.8 0.7 9.5 5.7 7.9 0.7 9.9 6.5 7.6 0.7 9.9 5.7 120 5 119 165 3.9 0 4 3.8 12/26/2005 13:30:00 7.8 0.7 10.7 6.1 8 0.7 10.3 6.1 7.5 0.7 9.9 6.1 118 5 112 165 4 0 4.3 3.8 12/26/2005 13:40:00 8.3 0.9 10.7 5.7 8.5 0.9 10.7 5.7 7.9 1 10.3 4.9 118 7 126 165 3.9 0 4 3.8 12/26/2005 13:50:00 7.5 0.7 9.1 5.7 7.7 0.7 9.5 5.3 7.3 0.9 9.5 4.6 120 8 110 165 3.9 0 4 3.8 12/26/2005 14:00:00 7.7 1 10.3 5.3 7.8 1 10.7 4.9 7.4 1.1 9.9 4.9 118 6 114 165 4 0 4.3 3.8 12/26/2005 14:10:00 10.1 1 13.3 7.6 10.3 1 13.3 8 9.8 1 13 7.2 122 8 118 165 3.9 0 4.3 3.8 12/26/2005 14:20:00 8.8 0.9 11.5 5.3 8.9 0.9 11.5 6.1 8.7 0.9 11.1 6.1 122 7 118 165 4 0 4.3 3.8 12/26/2005 14:30:00 7.8 0.7 9.5 5.7 8 0.7 9.9 5.7 7.4 0.9 9.5 5.3 112 5 107 165 4 0 4.3 4 12/26/2005 14:40:00 8.4 0.6 10.3 6.8 8.6 0.6 10.3 7.2 8 0.8 9.9 5.3 109 5 106 165 4 0 4 3.8 12/26/2005 14:50:00 9 0.7 11.1 6.8 9.2 0.7 11.1 6.8 8.6 0.9 10.3 6.1 106 6 101 165 4 0 4.3 3.8 12/26/2005 15:00:00 8.8 0.8 11.1 6.5 9.1 0.8 11.1 6.8 8.4 0.9 10.7 5.7 109 5 105 165 4 0 4.3 3.8 12/26/2005 15:10:00 8.2 0.6 10.3 5.7 8.4 0.7 10.3 5.3 7.8 0.8 9.9 5.3 109 4 107 165 4 0 4.3 3.8 12/26/2005 15:20:00 7.5 1.1 10.3 4.9 7.7 1.2 10.7 4.9 7 1.3 9.9 4.2 98 6 99 165 4 0 4.3 3.8 12/26/2005 15:30:00 9.1 1 11.5 6.5 9.2 1 11.8 6.1 8.4 1 11.1 6.1 112 9 112 165 4.1 0 4.3 3.8 12/26/2005 15:40:00 9.9 1.2 14.1 6.8 10.1 1.2 14.9 6.5 9.6 1.3 14.1 5.7 120 9 112 165 4 0.1 4.3 3.5 12/26/2005 15:50:00 9.6 1 12.6 6.8 9.8 1 12.6 7.6 9.1 1.1 11.8 6.1 108 7 113 165 3.7 0 3.8 3.5 12/26/2005 16:00:00 8.8 0.8 10.3 6.5 9 0.8 11.1 6.5 8.2 0.9 10.3 5.7 97 5 94 165 4 0 4.3 3.8 12/26/2005 16:10:00 8.9 0.7 10.3 5.3 9.1 0.7 10.7 5.7 8.2 0.9 10.3 5.3 102 5 96 165 3.9 0 4 3.8 12/26/2005 16:20:00 9.1 1 11.1 6.1 9.4 1 11.5 6.1 8.6 1.1 11.1 5.3 104 5 104 165 3.8 0 4 3.8 12/26/2005 16:30:00 10 0.8 11.8 7.2 10.2 0.8 12.2 7.2 9.2 0.9 11.5 6.8 103 5 105 165 4 0 4.3 3.8 12/26/2005 16:40:00 9.9 1 12.2 6.5 10.2 1 12.2 6.5 9.3 1.1 11.8 6.1 102 7 98 165 4.1 0 4.3 4 12/26/2005 16:50:00 10.6 1.2 13.3 7.2 10.8 1.3 13.7 7.6 9.7 1.3 13 6.5 95 6 99 165 4.1 0 4.3 4.3 12/26/2005 17:00:00 11.1 1.1 13.7 7.6 11.3 1.2 14.1 7.6 10.3 1.3 13 7.2 99 6 104 165 3.8 0.2 4.3 3.5 12/26/2005 17:10:00 11.4 1.1 13.7 8 11.6 1.1 14.5 8.4 10.7 1 13.3 8 104 5 102 165 3.6 0 3.8 3.5 12/26/2005 17:20:00 10.1 0.9 12.2 6.5 10.3 0.9 12.2 6.8 9.4 1 12.2 6.8 95 6 98 165 3.6 0 3.8 3.5 12/26/2005 17:30:00 10.2 1.1 13 7.6 10.5 1.1 13.3 7.6 9.7 1.2 12.2 6.5 87 6 100 165 3.8 0 4 3.5 12/26/2005 17:40:00 9.9 0.9 11.8 7.2 10.2 1 12.6 7.2 9.3 1 11.8 6.8 85 5 91 165 4 0 4 3.8 12/26/2005 17:50:00 9.6 0.9 11.5 6.8 9.9 1 11.8 7.2 9.1 1 11.5 6.8 85 5 92 165 3.9 0 4 3.8 12/26/2005 18:00:00 9.8 1 12.2 7.6 10 1 12.2 7.6 9 1 11.5 6.1 91 7 103 165 3.9 0 4 3.8 12/26/2005 18:10:00 9.8 1.1 12.6 6.8 10.1 1.1 13 7.2 9.1 1.2 11.8 6.5 92 7 90 165 4 0 4.3 3.8 12/26/2005 18:20:00 10.3 1 12.2 5.7 10.6 1 12.2 6.1 9.7 1 11.8 6.8 87 5 88 165 4.1 0 4.3 4 12/26/2005 18:30:00 10.5 0.9 12.6 8 10.7 1 13 7.6 9.9 1 12.2 7.6 82 6 85 165 4.1 0 4.3 4.3 12/26/2005 18:40:00 11.2 1 13.7 8.4 11.5 1 13.7 8.8 10.7 1.2 13.7 5.7 83 5 91 165 4.3 0 4.5 4.3 12/26/2005 18:50:00 10.1 1 12.6 7.2 10.3 1 12.6 7.6 9.5 1.2 13 6.8 82 6 83 165 4.3 0 4.5 4.3 12/26/2005 19:00:00 9.8 1.1 11.8 6.8 10.1 1.1 12.2 6.8 9.5 1.1 11.8 6.1 78 6 74 165 4.3 0 4.5 4.3 12/26/2005 19:10:00 9.8 1 12.2 6.8 10 1.1 12.6 6.8 9.5 1 11.5 7.2 80 7 83 165 4.3 0 4.5 4.3 12/26/2005 19:20:00 9.6 1.3 12.6 6.5 9.9 1.3 13 6.8 9.3 1.2 12.2 6.1 81 7 84 165 4.3 0 4.5 4.3 12/26/2005 19:30:00 10 1.1 13.7 7.2 10.3 1.1 13.3 7.2 9.7 1.1 13 6.8 77 6 77 165 4.2 0 4.5 4.3 12/26/2005 19:40:00 9 1.2 11.8 4.9 9.2 1.3 12.6 4.6 8.7 1.1 11.5 5.7 77 7 84 165 4.2 0 4.3 4.3 12/26/2005 19:50:00 9.1 1.5 13.3 5.3 9.3 1.5 13.3 5.7 8.8 1.5 13.7 5.3 75 9 74 165 4.1 0 4.3 4.3 12/26/2005 20:00:00 10.5 1.7 15.3 7.2 10.7 1.7 15.3 6.5 9.9 1.7 14.9 6.5 85 10 88 165 4 0.1 4.3 3.5 12/26/2005 20:10:00 8.8 1.2 11.5 5.7 9 1.2 11.5 5.7 8.5 1.1 11.5 4.9 73 10 94 165 3.5 0 3.8 3.5 12/26/2005 20:20:00 8.3 1.1 11.1 5.7 8.5 1.1 11.1 6.1 7.9 1 10.7 5.7 68 8 58 165 3.8 0 4.3 3.5 12/26/2005 20:30:00 6.9 0.8 8.8 4.9 7.1 0.8 9.1 4.9 6.5 0.8 8.8 4.2 62 9 66 165 4.1 0 4.3 3.8 12/26/2005 20:40:00 6.9 1.3 10.3 3.8 7 1.3 10.3 3.8 6.5 1.3 9.5 4.2 57 10 73 165 4.1 0 4.3 4 12/26/2005 20:50:00 7.2 1.1 10.3 4.6 7.4 1.2 10.7 4.9 7.1 1.3 9.9 3.4 58 8 52 165 4.1 0 4.3 3.8 12/26/2005 21:00:00 7.8 1.1 11.5 4.6 8 1.1 11.5 4.6 7.5 1 10.3 3.8 60 8 62 165 3.8 0 4 3.8 12/26/2005 21:10:00 7.2 1.1 10.3 4.2 7.4 1.2 10.3 4.2 6.8 1.2 9.9 4.2 62 9 65 165 3.6 0 3.8 3.5 12/26/2005 21:20:00 7.1 1.2 10.7 4.6 7.3 1.2 10.7 4.6 6.9 1.1 9.5 4.6 65 9 80 165 3.8 0 3.8 3.5 12/26/2005 21:30:00 6.5 1 8.8 3.8 6.7 1 9.5 3.8 6.3 1 8.8 3.8 62 10 81 165 3.9 0 4 3.8 12/26/2005 21:40:00 6.4 1.2 9.9 3.8 6.5 1.2 10.3 3.4 6 1 8.8 3.4 60 8 73 165 4 0 4.3 3.8 12/26/2005 21:50:00 6 1.2 11.5 3 6.1 1.2 12.6 3.4 5.6 1 10.3 2.6 64 12 106 165 4.1 0 4.3 4 12/26/2005 22:00:00 7 1.1 9.5 4.2 7.1 1.1 9.9 3.8 6.6 1.1 9.1 3.8 56 9 68 165 4.3 0 4.5 4.3 12/26/2005 22:10:00 7.5 1.2 10.3 3.8 7.6 1.3 10.7 3.8 7.1 1.2 9.9 4.2 49 9 52 165 4.4 0 4.5 4.3 12/26/2005 22:20:00 6.4 1.1 9.5 3.4 6.4 1.2 9.9 3 6.1 1 8.4 3.4 50 11 62 165 4.4 0 4.5 4.5 12/26/2005 22:30:00 7.1 1.2 10.7 4.2 7.2 1.2 11.1 4.2 6.9 1.2 11.5 4.2 56 9 71 165 4.5 0 4.8 4.5 12/26/2005 22:40:00 7.9 1.4 11.1 3.8 8 1.4 11.5 3.8 7.4 1.3 11.5 4.2 54 10 65 165 4.6 0 4.8 4.5 12/26/2005 22:50:00 8 1.3 11.1 4.2 8.1 1.5 11.5 4.6 7.6 1.3 11.8 4.6 51 9 53 165 4.6 0 4.8 4.5 12/26/2005 23:00:00 7.5 1.6 13.7 4.6 7.5 1.7 14.1 4.6 7 1.5 12.2 4.6 53 12 64 165 4.6 0 4.8 4.5 12/26/2005 23:10:00 9.8 1.7 16.1 4.2 10 1.8 16.4 4.6 9.5 1.7 14.9 5.3 57 12 52 165 4.5 0 4.8 4.5 12/26/2005 23:20:00 9.4 1.4 12.2 4.9 9.6 1.5 13 4.9 9.2 1.3 12.2 6.1 66 9 68 165 4.6 0 4.8 4.5 12/26/2005 23:30:00 9 1.7 13.3 4.9 9.2 1.8 13.3 4.9 9 1.5 13 5.3 70 9 73 165 4.6 0 4.8 4.5 12/26/2005 23:40:00 9.2 1.5 13.3 4.6 9.4 1.5 13.7 4.9 8.8 1.5 12.6 5.3 63 10 62 165 4.5 0 4.8 4.5 12/26/2005 23:50:00 10.1 1.7 14.5 6.1 10.3 1.8 14.9 6.5 9.8 1.7 14.5 6.5 64 9 63 165 4.4 0 4.5 4.3 12/27/2005 00:00:00 8.2 1.6 11.5 4.2 8.3 1.7 11.8 4.6 7.8 1.5 11.8 4.6 58 11 56 165 4.4 0 4.5 4.3 12/27/2005 00:10:00 8.9 1.7 13.3 5.3 9 1.8 13.7 5.3 8.5 1.8 14.5 4.9 51 12 48 165 4.3 0 4.5 4.3 12/27/2005 00:20:00 9.7 1.7 14.1 6.1 9.9 1.8 14.5 6.1 9.4 1.7 14.1 5.3 61 11 73 165 4.3 0 4.5 4.3 12/27/2005 00:30:00 10.6 1.9 15.6 6.5 10.7 2 16.1 6.5 10.1 1.8 15.3 6.1 57 13 20 165 4.3 0 4.5 4.3 12/27/2005 00:40:00 9.2 1.9 14.1 4.9 9.2 2 14.5 4.9 8.8 1.7 13.3 4.9 47 12 73 165 4.3 0 4.5 4.3 12/27/2005 00:50:00 9.6 1.6 13.7 6.1 9.7 1.7 13.7 6.1 9.2 1.7 13.3 5.3 50 12 56 165 4.1 0 4.5 4 12/27/2005 01:00:00 8.2 1.3 11.5 4.9 8.1 1.3 11.5 4.9 7.8 1.2 11.1 4.9 41 10 41 165 4.1 0 4.3 4 12/27/2005 01:10:00 8.4 1.4 11.8 4.9 8.4 1.5 12.6 4.9 7.9 1.4 11.8 4.6 44 13 38 165 4.1 0 4.3 4 12/27/2005 01:20:00 7.9 1.5 13 4.9 8 1.6 13 4.9 7.6 1.5 12.6 4.6 48 12 53 165 4.1 0 4.3 4 12/27/2005 01:30:00 9.2 2.3 16.4 4.9 9.2 2.4 16.1 5.3 8.8 2.3 16.4 5.3 44 11 39 165 4 0 4.3 3.8 12/27/2005 01:40:00 8.9 1.9 14.5 4.9 8.9 2 14.5 4.6 8.3 1.9 13.3 3.8 47 13 68 165 4 0 4 3.8 12/27/2005 01:50:00 9.4 1.7 14.1 5.7 9.4 1.7 13.7 4.9 9.1 1.7 14.1 5.3 49 12 50 165 4 0 4.3 3.8 12/27/2005 02:00:00 9.6 1.6 13.7 6.1 9.6 1.7 13.7 5.3 9.1 1.6 13.7 4.9 41 10 41 165 4 0 4.3 3.8 12/27/2005 02:10:00 9.6 1.7 13.3 4.9 9.6 1.7 13.3 4.9 9.1 1.6 12.6 4.6 39 9 29 165 4 0 4.3 3.8 12/27/2005 02:20:00 10.5 1.5 13.7 6.1 10.4 1.5 13.7 5.3 10 1.5 13.7 6.1 38 8 29 165 4 0 4.3 3.8 12/27/2005 02:30:00 9.9 1.5 13.3 5.3 9.9 1.5 13.3 5.7 9.7 1.5 13.3 6.1 38 7 46 165 4 0 4.3 4 12/27/2005 02:40:00 11 1.3 14.1 6.8 10.9 1.4 13.7 6.8 10.5 1.6 14.1 6.5 34 8 39 165 4.1 0 4.3 4 12/27/2005 02:50:00 11 1.5 15.3 6.8 10.8 1.5 14.9 6.5 10.2 1.6 14.1 6.5 31 8 40 165 4.1 0 4.3 4.3 12/27/2005 03:00:00 9.3 1.4 12.6 6.1 9 1.5 12.6 5.7 8.8 1.5 12.6 4.6 25 10 28 165 4.1 0 4.5 4.3 12/27/2005 03:10:00 10.4 1.7 14.9 6.5 10.2 1.9 14.9 6.1 9.9 1.7 14.9 6.1 27 9 32 165 4.2 0 4.5 4.3 12/27/2005 03:20:00 11.5 1.5 15.3 7.6 11.3 1.6 15.3 6.8 10.9 1.6 15.3 6.8 29 9 40 165 4.3 0 4.5 4.3 12/27/2005 03:30:00 11.9 1.5 15.3 8.4 11.8 1.5 15.3 8 11.2 1.6 16.1 8 35 7 22 165 4.3 0 4.5 4.3 12/27/2005 03:40:00 10.7 1.4 14.9 6.8 10.7 1.4 14.5 6.5 10.3 1.3 13.7 6.1 37 9 41 165 4.3 0 4.5 4.3 12/27/2005 03:50:00 11.4 1.6 15.3 7.2 11.3 1.7 14.9 7.2 10.8 1.7 14.5 5.7 34 8 36 165 4.4 0 4.5 4.3 12/27/2005 04:00:00 11.5 1.5 16.1 7.6 11.4 1.6 15.3 7.2 10.8 1.7 14.5 6.1 32 9 32 165 4.4 0 4.5 4.3 12/27/2005 04:10:00 13.4 1.7 17.6 8.4 13.2 1.8 17.6 8 12.8 1.9 18.3 8.8 34 9 39 165 4.5 0 4.5 4.5 12/27/2005 04:20:00 11.6 1.6 16.1 7.2 11.5 1.7 16.1 6.5 11.2 1.7 16.4 6.5 33 9 57 165 4.5 0 4.8 4.5 12/27/2005 04:30:00 11.9 1.8 15.6 7.6 11.8 1.9 16.1 7.2 11.3 1.9 16.1 5.7 30 9 34 165 4.5 0 4.8 4.5 12/27/2005 04:40:00 12.2 2 17.9 8 12 2.1 17.9 7.2 11.5 2.1 18.7 7.2 32 9 39 165 4.5 0 4.8 4.5 12/27/2005 04:50:00 12.2 1.9 17.9 7.2 12 2 18.3 6.8 11.7 1.8 17.9 7.2 30 9 24 165 4.5 0 4.5 4.5 12/27/2005 05:00:00 12.3 1.8 16.8 7.6 12.2 1.8 16.8 7.2 11.9 1.7 16.4 6.8 34 8 30 165 4.5 0 4.8 4.5 12/27/2005 05:10:00 11.2 1.6 16.4 7.6 11.1 1.6 16.4 7.6 10.7 1.7 17.6 6.8 37 9 37 165 4.5 0 4.8 4.3 12/27/2005 05:20:00 11.1 1.8 16.1 6.5 11.1 1.9 16.1 6.1 10.7 1.7 15.3 6.1 37 10 49 165 4.5 0 4.8 4.5 12/27/2005 05:30:00 10.2 1.8 15.3 6.5 10.1 1.8 15.3 5.7 9.8 1.8 15.3 5.3 36 9 44 165 4.6 0 4.8 4.5 12/27/2005 05:40:00 11.9 1.7 15.6 6.8 11.8 1.7 16.1 6.5 11.2 1.8 14.5 5.7 35 8 43 165 4.6 0 4.8 4.5 12/27/2005 05:50:00 11.9 1.9 16.8 5.3 11.8 1.9 16.8 5.3 11.5 1.9 16.4 6.1 33 9 31 165 4.6 0 4.8 4.5 12/27/2005 06:00:00 12.6 2 17.6 6.5 12.5 2 17.2 6.5 12.2 2.2 17.2 7.2 33 8 36 165 4.6 0 4.8 4.5 12/27/2005 06:10:00 13 1.7 16.4 8 12.8 1.7 16.8 7.6 12.5 1.8 17.2 7.6 33 8 31 165 4.6 0 4.8 4.5 12/27/2005 06:20:00 12.3 1.4 16.8 8 12.2 1.5 16.4 8 11.8 1.5 16.1 8 33 8 39 165 4.6 0 4.8 4.5 12/27/2005 06:30:00 12.8 2.1 18.7 8 12.7 2.2 18.7 8 12.2 2.3 19.1 6.8 33 9 36 165 4.6 0 4.8 4.5 12/27/2005 06:40:00 13.1 1.9 19.1 8.4 13 2 19.1 8 12.5 1.8 17.9 8 32 9 36 165 4.6 0 4.8 4.5 12/27/2005 06:50:00 12.9 1.7 17.2 7.2 12.7 1.7 17.2 7.2 12.2 1.7 16.1 7.6 31 9 35 165 4.6 0 4.8 4.5 12/27/2005 07:00:00 13.3 1.9 17.6 8 13.2 2 17.6 8 12.9 1.8 17.6 8.4 34 8 37 165 4.6 0 4.8 4.5 12/27/2005 07:10:00 11.9 1.6 16.4 8 11.8 1.7 16.4 8 11.3 1.7 16.4 7.6 34 8 48 165 4.7 0 4.8 4.5 12/27/2005 07:20:00 13 2.1 17.6 8 13 2.1 17.6 8 12.4 2 17.9 8 35 8 28 165 4.7 0 4.8 4.5 12/27/2005 07:30:00 12.5 1.9 18.7 7.6 12.5 2 19.1 7.6 12.2 2 17.6 8 35 8 37 165 4.7 0 4.8 4.8 12/27/2005 07:40:00 12.7 1.8 17.2 8.4 12.6 1.9 16.8 7.6 12.2 2.1 17.9 7.6 33 9 34 165 4.7 0 5 4.8 12/27/2005 07:50:00 12.4 2 16.8 7.2 12.3 2 17.2 7.6 11.9 2 16.4 6.8 35 8 34 165 4.7 0 4.8 4.8 12/27/2005 08:00:00 12.4 1.7 17.2 8 12.4 1.9 17.2 8 11.9 2.1 16.8 7.2 36 8 27 165 4.7 0 4.8 4.8 12/27/2005 08:10:00 10.5 1.6 15.3 6.5 10.5 1.7 15.3 6.5 9.8 1.5 14.5 6.5 43 10 34 165 4.9 0 5 4.8 12/27/2005 08:20:00 8.5 1.9 14.5 4.6 8.6 2 14.5 4.6 8.2 1.7 13 4.6 51 11 56 165 4.9 0 5 4.8 12/27/2005 08:30:00 9.8 1.7 14.9 5.3 9.8 1.7 14.5 5.7 9.2 1.8 14.5 5.7 48 10 40 165 4.9 0 5 4.8 12/27/2005 08:40:00 9 1.8 13.7 5.3 9.1 1.8 13.7 4.9 8.5 1.7 13.7 4.9 42 9 49 165 4.9 0 5 4.8 12/27/2005 08:50:00 8.7 1.3 11.1 4.9 8.6 1.3 11.5 4.9 8.2 1.3 11.5 4.9 36 8 37 165 4.9 0 5 5 12/27/2005 09:00:00 9.5 1.5 13 5.7 9.4 1.6 13.3 5.7 9.2 1.7 13.3 5.7 32 9 28 165 4.9 0 5 4.8 12/27/2005 09:10:00 10.5 1.4 13.7 6.5 10.5 1.5 13.7 6.5 9.9 1.6 13.7 5.3 34 8 39 165 4.9 0 5 4.8 12/27/2005 09:20:00 9.2 1.3 13.7 6.8 9.1 1.3 13.7 6.5 8.7 1.4 14.1 4.9 32 9 34 165 4.9 0 5 4.8 12/27/2005 09:30:00 10 1.2 13.3 6.8 9.8 1.3 13.3 6.1 9.5 1.3 13.3 6.5 30 10 26 165 4.9 0 5 4.8 12/27/2005 09:40:00 10.6 1.4 14.1 7.2 10.4 1.5 13.7 6.8 10 1.5 14.1 6.5 30 10 34 165 4.9 0 5 4.8 12/27/2005 09:50:00 11.4 1.5 14.9 8 11.2 1.5 14.9 7.6 10.7 1.6 14.5 7.2 32 9 29 165 4.9 0 5 4.8 12/27/2005 10:00:00 11.1 1.6 14.9 6.8 10.9 1.7 15.3 6.8 10.5 1.7 14.9 6.5 31 9 34 165 4.9 0 5 4.8 12/27/2005 10:10:00 10 1.5 14.5 6.5 9.8 1.6 14.5 6.5 9.5 1.7 14.9 6.1 28 9 22 165 4.9 0 5 4.8 12/27/2005 10:20:00 10.1 1.5 14.1 5.7 10 1.6 14.1 5.3 9.6 1.6 14.1 4.6 36 10 34 165 4.9 0 5 5 12/27/2005 10:30:00 10.7 1.4 14.1 6.8 10.6 1.5 14.1 6.8 10.2 1.5 14.1 6.8 34 9 39 165 4.9 0 5 5 12/27/2005 10:40:00 11.1 1.9 16.4 6.8 11 2 16.8 6.8 10.6 2.1 16.8 5.7 32 9 36 165 5 0 5.2 5 12/27/2005 10:50:00 12 1.8 15.3 7.6 11.9 1.9 15.3 6.8 11.6 2 15.3 6.8 35 9 37 165 5 0 5 5 12/27/2005 11:00:00 11.9 1.9 16.4 6.8 11.7 2 16.4 6.8 11.3 2 16.4 6.8 32 9 35 165 5.1 0 5.2 5 12/27/2005 11:10:00 12.7 2.2 17.9 7.2 12.5 2.2 17.6 6.5 12 2.3 17.2 6.5 34 9 34 165 5 0 5.2 5 12/27/2005 11:20:00 13.4 2 18.7 8.8 13.4 2.1 18.7 8.8 13 2 18.3 8.4 38 10 41 165 4.9 0 5 4.8 12/27/2005 11:30:00 12.2 2 17.2 6.8 12.1 2.1 17.6 6.8 11.6 2.1 17.2 6.8 38 9 43 165 4.7 0 5 4.8 12/27/2005 11:40:00 13 1.9 19.1 7.6 12.9 2.1 19.1 7.2 12.3 2.2 16.8 6.1 38 10 25 165 4.7 0 4.8 4.8 12/27/2005 11:50:00 12.2 1.7 16.8 8 12 1.7 16.8 7.2 11.8 2 16.4 7.2 31 9 33 165 4.7 0 4.8 4.5 12/27/2005 12:00:00 11.9 1.7 16.8 7.6 11.7 1.8 16.8 7.2 11.5 1.7 16.4 7.2 32 9 48 165 4.6 0 4.8 4.5 12/27/2005 12:10:00 11.6 1.6 16.4 7.2 11.4 1.7 16.4 6.8 11.2 1.8 15.6 6.8 30 9 29 165 4.7 0 4.8 4.8 12/27/2005 12:20:00 11.7 1.8 16.8 8 11.5 1.9 16.8 7.6 11.1 1.8 16.4 7.6 30 10 42 165 4.7 0 4.8 4.8 12/27/2005 12:30:00 13.4 2.2 18.3 7.6 13.2 2.3 17.9 7.6 12.7 2.3 17.6 6.8 30 9 31 165 4.7 0 5 4.8 12/27/2005 12:40:00 14.1 2.4 20.6 8.4 14 2.5 20.6 8.4 13.6 2.6 21.4 7.6 33 9 41 165 4.6 0 4.8 4.5 12/27/2005 12:50:00 13.6 2.2 18.3 8 13.4 2.3 19.1 7.6 13 2.1 17.9 8 31 10 46 165 4.6 0 4.8 4.5 12/27/2005 13:00:00 14.7 2.4 21 9.5 14.2 2.4 21 8.8 13.8 2.2 19.9 7.6 23 10 40 165 4.6 0 4.8 4.5 12/27/2005 13:10:00 14.5 2.3 20.6 9.1 14.1 2.4 19.9 8.4 14 2.3 19.9 8.8 25 9 22 165 4.5 0 4.5 4.5 12/27/2005 13:20:00 15 2.2 21.8 9.9 14.6 2.3 21.4 9.5 14.3 2.1 19.9 9.9 25 10 28 165 4.5 0 4.8 4.5 12/27/2005 13:30:00 14.5 2.5 20.6 8.8 14.1 2.6 20.6 8.8 13.9 2.4 20.2 7.6 26 10 28 165 4.5 0 4.8 4.5 12/27/2005 13:40:00 16 2.6 22.9 9.1 15.7 2.7 22.9 9.1 15.1 2.7 21.8 8.8 25 10 35 165 4.4 0 4.5 4.5 12/27/2005 13:50:00 16.1 2.5 21.8 10.3 15.8 2.6 21.8 10.7 15.6 2.4 21.8 9.5 29 9 21 165 4.4 0 4.5 4.3 12/27/2005 14:00:00 15.7 2.6 22.9 9.9 15.4 2.7 22.9 8.8 14.7 2.6 21.8 9.5 28 10 27 165 4.3 0 4.5 4.3 12/27/2005 14:10:00 16.4 2.5 21.4 10.7 16.1 2.6 21.4 9.9 15.4 2.6 21 9.1 28 8 32 165 4.3 0 4.5 4.3 12/27/2005 14:20:00 16.8 2.8 22.6 8 16.5 2.9 22.9 8 16 2.9 21.8 8.4 27 9 37 165 4.3 0 4.5 4.3 12/27/2005 14:30:00 17 2.7 24.8 10.3 16.8 2.9 24.8 10.3 16.3 2.8 24.8 9.9 27 9 32 165 4.3 0 4.5 4.3 12/27/2005 14:40:00 15.9 2.2 21 9.1 15.6 2.4 21 9.1 15.2 2.3 21.4 8.8 25 9 37 165 4.3 0 4.5 4.3 12/27/2005 14:50:00 15.7 2.6 23.3 10.3 15 2.7 22.6 9.5 15 2.6 23.7 9.5 21 10 16 165 4.3 0 4.5 4.3 12/27/2005 15:00:00 15.7 2.1 21.4 10.7 15 2.3 21.8 9.9 14.7 2.2 20.2 10.3 21 9 30 165 4.3 0 4.5 4.3 12/27/2005 15:10:00 15.6 2.1 20.2 11.1 14.7 2.3 19.9 10.3 14.5 2.1 20.2 9.9 18 8 26 165 4.3 0 4.5 4.3 12/27/2005 15:20:00 15.5 1.9 19.9 9.5 14.4 1.9 19.1 9.1 14.7 2 20.2 9.1 17 8 16 165 4.3 0 4.5 4.3 12/27/2005 15:30:00 15.2 1.9 19.9 10.3 14.4 2.2 19.1 8 14.5 1.7 18.7 9.9 18 9 7 165 4.3 0 4.5 4.3 12/27/2005 15:40:00 15.6 2 19.9 10.7 14.9 2.3 19.9 8.4 14.6 2.2 20.2 9.5 18 9 16 165 4.3 0 4.5 4.3 12/27/2005 15:50:00 15.7 2.3 21.4 8.4 15.1 2.6 21.8 7.2 14.8 2.3 20.2 8.8 22 9 34 165 4.3 0 4.5 4.3 12/27/2005 16:00:00 16.5 2.5 23.3 11.1 15.9 2.6 23.3 9.9 15.7 2.3 22.9 10.7 22 9 32 165 4.2 0 4.5 4.3 12/27/2005 16:10:00 17.4 3.1 24.8 10.7 16.9 3.3 24.4 9.5 16.6 2.8 24.4 9.9 25 9 39 165 4.1 0 4.3 4.3 12/27/2005 16:20:00 18.4 2.8 26 10.7 18 2.9 24.8 9.1 17.6 2.7 23.7 11.1 26 9 19 165 4.1 0 4.3 4.3 12/27/2005 16:30:00 17 2.5 24.4 11.5 16.5 2.7 24.4 10.3 16 2.5 23.3 10.3 24 9 23 165 4.2 0 4.5 4.3 12/27/2005 16:40:00 16.4 2.5 21.4 9.9 16 2.5 21.4 9.5 15.8 2.7 21.4 9.9 25 9 6 165 4.3 0 4.5 4.3 12/27/2005 16:50:00 16 2.2 22.1 10.3 15.5 2.3 21.8 8.8 15.2 2.3 21.4 9.9 24 9 31 165 4.4 0 4.5 4.3 12/27/2005 17:00:00 16.3 2.6 23.7 9.5 15.9 2.8 24 9.1 15.3 2.6 23.7 10.3 25 9 27 165 4.5 0 4.8 4.5 12/27/2005 17:10:00 15.8 2.3 21.8 10.3 15.4 2.5 21 9.9 15.2 2.3 22.1 10.3 24 9 23 165 4.6 0 4.8 4.5 12/27/2005 17:20:00 16 2.4 21.8 10.7 15.6 2.4 21.4 9.1 15.2 2.5 20.6 8.4 26 9 28 165 4.6 0 4.8 4.5 12/27/2005 17:30:00 15.7 2.7 23.3 10.3 15.4 2.8 23.3 9.5 14.9 2.6 22.1 9.1 28 9 31 165 4.7 0 4.8 4.8 12/27/2005 17:40:00 14.3 2.8 21.4 8.4 14.1 2.8 21.4 8.8 13.4 2.7 21 8.4 31 9 32 165 4.8 0 5 4.8 12/27/2005 17:50:00 14.5 2.2 19.9 8.8 14.4 2.3 20.2 8.4 13.9 2.1 19.9 8.4 32 8 31 165 4.9 0 5 4.8 12/27/2005 18:00:00 13.7 1.9 18.3 9.9 13.6 2 18.3 9.5 13.1 2.2 17.9 8 36 9 27 165 5 0 5 4.8 12/27/2005 18:10:00 11.8 2.1 17.6 6.5 11.8 2.1 17.6 6.8 11.4 2.1 16.8 6.1 37 8 34 165 5.1 0 5.2 5 12/27/2005 18:20:00 10.8 2 16.1 6.1 10.9 2 16.1 5.7 10.4 2 14.9 5.7 43 10 48 165 5.2 0 5.5 5 12/27/2005 18:30:00 10.2 2 15.6 4.6 10.2 2 15.6 4.6 9.5 2.1 15.6 3.8 36 9 47 165 5.2 0 5.5 5.2 12/27/2005 18:40:00 11.4 1.7 15.6 6.5 11.3 1.7 15.6 6.5 10.9 1.7 14.9 6.8 40 10 46 165 5.3 0 5.5 5.2 12/27/2005 18:50:00 10 1.7 14.1 6.1 9.9 1.7 14.5 6.1 9.5 1.7 13.7 5.3 39 10 54 165 5.4 0 5.5 5.2 12/27/2005 19:00:00 10.2 1.9 14.9 4.9 10.3 1.9 14.5 4.9 9.8 1.7 14.1 5.3 49 12 65 165 5.3 0 6 5 12/27/2005 19:10:00 11.3 2.2 17.9 6.8 11.4 2.3 17.6 6.8 10.9 2 16.1 6.8 58 11 50 165 4.9 0 5.2 4.8 12/27/2005 19:20:00 9.7 1.7 14.1 5.7 9.9 1.8 14.5 5.7 9.2 1.7 13.7 5.3 61 11 71 165 4.9 0 5.2 4.8 12/27/2005 19:30:00 9.1 2 14.9 4.9 9.3 2.1 15.3 4.9 8.6 1.9 14.5 4.6 54 12 56 165 5.2 0.1 5.2 5 12/27/2005 19:40:00 9.2 1.8 15.3 4.9 9.4 2 16.4 5.3 9 1.9 15.6 4.9 59 12 67 165 5.2 0 5.5 5.2 12/27/2005 19:50:00 9.5 1.7 14.1 4.9 9.6 1.7 14.9 5.3 9 1.7 13.7 4.9 58 11 68 165 5.2 0 5.2 5 12/27/2005 20:00:00 9.6 2 14.9 5.7 9.8 2 15.6 6.1 9.2 1.8 14.1 5.3 60 10 58 165 5 0 5.2 5 12/27/2005 20:10:00 9.5 1.5 13.3 6.5 9.7 1.5 13.7 6.5 9.1 1.2 12.2 5.7 57 11 61 165 4.9 0 5 5 12/27/2005 20:20:00 9 1.6 14.1 5.3 9.1 1.7 14.5 5.3 8.7 1.5 13.7 4.9 53 10 61 165 5 0 5.2 5 12/27/2005 20:30:00 8.4 1.5 11.8 3.8 8.6 1.6 11.8 4.2 8.1 1.5 12.2 4.6 50 10 53 165 4.9 0 5 5 12/27/2005 20:40:00 8.6 1.5 11.8 4.9 8.7 1.6 12.2 4.9 8.2 1.5 11.8 4.9 47 9 32 165 4.9 0 5.2 4.8 12/27/2005 20:50:00 8.8 1.5 13.7 4.6 8.9 1.5 14.1 4.6 8.2 1.3 12.6 4.9 48 9 58 165 4.9 0 5 5 12/27/2005 21:00:00 9.1 1.5 13.7 4.9 9.3 1.5 13.3 5.3 8.7 1.2 12.2 5.7 50 10 39 165 5 0 5.2 5 12/27/2005 21:10:00 8.7 2.2 13.3 3.4 8.8 2.3 13.7 3.4 8.3 2.3 13.7 3.8 56 11 38 165 4.8 0.1 5 4.8 12/27/2005 21:20:00 8.5 1.6 13 5.3 8.7 1.7 13 5.3 8.1 1.6 12.2 4.6 59 10 56 165 4.6 0 4.8 4.5 12/27/2005 21:30:00 7.5 1.4 11.1 4.2 7.6 1.5 11.1 4.2 7.3 1.4 10.7 3.8 52 17 68 165 4.6 0 4.8 4.5 12/27/2005 21:40:00 8.8 1.5 13 5.3 8.9 1.5 13 5.3 8.5 1.6 12.6 4.9 47 11 40 165 4.7 0.1 5 4.5 12/27/2005 21:50:00 9.7 1.9 14.5 5.7 9.8 2 14.9 5.3 9.1 1.8 13.3 4.6 55 10 73 165 5 0 5 4.8 12/27/2005 22:00:00 9.7 1.5 13.7 5.7 9.8 1.6 14.1 5.7 9.4 1.7 13.3 4.9 58 11 59 165 5.1 0 5.2 5 12/27/2005 22:10:00 10.3 1.6 14.5 6.5 10.4 1.7 14.5 6.5 9.9 1.7 14.5 6.1 60 11 58 165 5.2 0 5.2 5 12/27/2005 22:20:00 11 1.9 16.1 6.8 11.2 2 16.8 6.5 10.6 2 16.8 6.8 63 9 65 165 5.2 0 5.2 5 12/27/2005 22:30:00 10.7 1.7 17.6 6.1 10.9 1.8 17.9 6.5 10.1 1.7 17.2 6.1 63 10 59 165 5.2 0 5.2 5.2 12/27/2005 22:40:00 10.9 1.7 15.6 6.1 11 1.8 15.6 6.1 10.3 1.7 14.1 6.1 65 10 71 165 5.2 0 5.5 5.2 12/27/2005 22:50:00 11.5 1.7 16.1 7.6 11.7 1.8 16.4 7.6 11.1 1.7 15.6 6.8 67 9 74 165 5.2 0 5.5 5.2 12/27/2005 23:00:00 10.9 1.6 14.9 6.5 11.1 1.7 14.9 6.8 10.5 1.6 14.5 6.1 68 9 65 165 5.2 0 5.5 5.2 12/27/2005 23:10:00 11.3 1.9 16.8 7.2 11.6 2 16.8 7.6 10.9 1.7 15.3 7.2 72 9 84 165 5.2 0 5.5 5.2 12/27/2005 23:20:00 11.5 1.7 15.6 7.2 11.6 1.7 16.1 7.6 10.9 1.7 14.9 6.8 66 9 84 165 5.2 0 5.2 5.2 12/27/2005 23:30:00 11.8 1.7 15.6 8 12.1 1.8 16.1 8.4 11.3 1.7 15.3 7.6 66 9 73 165 5.2 0 5.5 5 12/27/2005 23:40:00 11.5 2.3 17.9 6.5 11.7 2.4 18.3 6.5 11.1 2.3 17.2 6.1 63 10 56 165 5.2 0 5.2 5 12/27/2005 23:50:00 11 2.1 17.2 6.8 11.1 2.2 17.6 6.5 10.6 2.1 17.6 5.7 61 10 70 165 5.2 0 5.2 5 12/28/2005 00:00:00 10.9 2.2 16.8 6.1 11 2.3 16.8 6.1 10.4 1.9 15.6 6.1 59 10 58 165 5.2 0 5.2 5 12/28/2005 00:10:00 11.1 1.8 15.3 6.5 11.3 1.9 15.6 6.5 10.6 1.9 14.9 4.9 66 11 65 165 5.2 0 5.2 5 12/28/2005 00:20:00 10.4 1.7 16.1 6.8 10.7 1.8 16.1 6.8 10.1 1.6 16.1 6.8 71 11 71 165 5 0 5.2 5 12/28/2005 00:30:00 10.3 1.5 14.1 6.5 10.5 1.6 14.9 6.8 9.9 1.6 14.5 6.1 70 9 49 165 5.1 0 5.2 5 12/28/2005 00:40:00 9.8 1.6 13.3 6.1 10 1.7 14.1 6.1 9.4 1.6 13.3 6.1 70 10 66 165 5.1 0 5.2 5 12/28/2005 00:50:00 9.8 1.7 14.1 4.9 10 1.7 14.1 5.3 9.3 1.7 13 5.3 65 10 78 165 5.1 0 5.2 5 12/28/2005 01:00:00 11.1 1.8 16.1 7.6 11.3 1.9 16.8 7.6 10.6 1.7 15.3 6.1 68 10 75 165 5.2 0 5.2 5 12/28/2005 01:10:00 11.2 1.9 15.3 6.5 11.5 2 15.6 6.5 10.7 1.9 15.3 6.1 67 9 66 165 5.2 0 5.2 5 12/28/2005 01:20:00 11.5 1.7 16.4 7.2 11.7 1.8 16.8 7.2 11 1.7 15.6 6.8 74 9 92 165 5.2 0 5.2 5 12/28/2005 01:30:00 10.9 1.6 14.9 6.5 11.1 1.7 15.3 7.2 10.5 1.7 14.9 6.5 74 9 72 165 5.2 0 5.2 5 12/28/2005 01:40:00 12.2 1.8 16.8 8 12.4 1.9 17.2 8 11.5 1.8 16.8 6.8 73 10 66 165 5.1 0 5.2 5 12/28/2005 01:50:00 13.7 1.8 18.3 9.1 14 1.9 18.7 9.1 13.2 1.8 17.6 8.8 81 7 87 165 5.1 0 5.2 5 12/28/2005 02:00:00 12.5 1.5 16.8 8.4 12.8 1.5 17.2 8.8 11.9 1.4 14.9 8.8 77 8 94 165 4.9 0 5 4.8 12/28/2005 02:10:00 11.5 1.8 15.3 7.2 11.7 1.8 15.6 7.2 11.1 1.7 14.5 6.8 75 9 86 165 4.9 0 5 4.8 12/28/2005 02:20:00 13.7 2.1 17.9 8.4 14 2.2 18.3 8.8 13.1 2 18.3 7.6 75 8 77 165 5.1 0 5 5 12/28/2005 02:30:00 13 2 18.7 8.8 13.3 2.1 19.1 8.8 12.4 2 17.6 7.2 86 10 103 165 5 0 5.2 4.8 12/28/2005 02:40:00 13.2 1.7 17.9 8 13.5 1.7 17.6 8 12.6 1.6 16.4 8.4 89 9 107 165 4.9 0 5 4.8 12/28/2005 02:50:00 13.2 1.9 19.5 9.1 13.5 2 19.5 9.5 12.4 2 17.9 8.4 81 8 80 165 5 0 5 5 12/28/2005 03:00:00 15.6 1.8 20.2 9.1 15.9 1.9 20.2 9.9 14.9 1.8 19.5 9.5 80 7 83 165 5.1 0 5.2 5 12/28/2005 03:10:00 15 1.7 19.9 10.7 15.4 1.7 20.2 10.7 14.3 1.7 18.3 9.5 80 8 76 165 5.1 0 5.2 5 12/28/2005 03:20:00 13.7 1.9 19.1 9.5 14 1.9 19.5 9.1 13.3 1.8 19.1 8.8 77 8 78 165 5 0 5 5 12/28/2005 03:30:00 13.6 1.5 17.6 9.5 13.9 1.7 18.7 9.9 13.1 1.5 17.9 9.1 77 8 77 165 4.9 0 5 5 12/28/2005 03:40:00 13.9 1.9 19.1 9.1 14.2 2 19.1 9.1 13.4 1.7 18.3 8.8 77 8 87 165 4.9 0 5 5 12/28/2005 03:50:00 14.2 2 19.5 8.8 14.5 2.1 19.5 8.8 13.6 2 19.1 8.8 76 8 74 165 5 0 5 5 12/28/2005 04:00:00 13.1 2 19.1 8 13.4 2.1 19.5 8.8 12.5 2.1 18.3 6.8 73 9 72 165 5 0 5 5 12/28/2005 04:10:00 12.1 2 17.2 8 12.3 2.1 17.9 8 11.6 1.9 16.4 7.2 73 9 78 165 4.9 0 5 4.8 12/28/2005 04:20:00 12.2 2.1 17.6 6.8 12.4 2.2 17.9 6.8 11.7 1.9 17.2 7.6 70 10 73 165 4.9 0 5 4.8 12/28/2005 04:30:00 12.3 1.9 16.8 7.2 12.5 2 17.2 7.2 11.8 2 17.9 6.8 73 10 85 165 4.9 0 5 4.8 12/28/2005 04:40:00 12.9 2.2 18.3 8 13.2 2.3 19.1 8.4 12.7 2 17.6 8 75 10 81 165 4.7 0 5 4.8 12/28/2005 04:50:00 14.5 2.4 20.2 8.8 14.8 2.5 20.6 8.8 13.9 2.3 20.2 8.8 77 9 91 165 4.6 0 4.8 4.5 12/28/2005 05:00:00 13.8 2.3 21 7.2 14.1 2.4 21.4 7.2 13.2 2.2 19.1 7.2 74 9 73 165 4.7 0 4.8 4.5 12/28/2005 05:10:00 12.9 2 17.6 8.4 13.2 2 18.3 8.8 12.7 1.9 17.9 9.1 72 9 87 165 4.7 0 4.8 4.8 12/28/2005 05:20:00 13.1 2.4 21 8.4 13.3 2.5 21.4 8.4 12.8 2.3 19.1 8 68 10 85 165 4.7 0 4.8 4.8 12/28/2005 05:30:00 12.7 1.9 17.2 7.6 12.9 2 17.9 7.6 12.2 1.8 17.9 6.8 71 11 70 165 4.8 0 5 4.8 12/28/2005 05:40:00 13.6 2.6 20.2 8.4 13.8 2.7 20.6 8.4 13 2.3 19.1 7.6 74 10 78 165 4.7 0 4.8 4.8 12/28/2005 05:50:00 12.6 2.4 19.5 7.2 12.8 2.5 19.5 7.6 12 2.5 18.3 6.1 76 13 99 165 4.7 0 4.8 4.5 12/28/2005 06:00:00 13.8 2.3 19.9 8 14.1 2.4 20.6 8.4 13.2 2.1 19.9 8.4 71 10 84 165 4.6 0 4.8 4.5 12/28/2005 06:10:00 12.8 2 17.6 8.8 13 2.1 18.3 8.4 12.5 1.9 17.6 8.4 71 11 75 165 4.6 0 4.8 4.5 12/28/2005 06:20:00 13.3 2.4 20.6 8.8 13.5 2.5 21 8.4 12.8 2.4 21 8 79 9 84 165 4.6 0 4.8 4.5 12/28/2005 06:30:00 14 2.3 20.2 9.1 14.4 2.3 20.6 9.5 13.6 2.3 21 8.4 78 10 71 165 4.5 0 4.5 4.5 12/28/2005 06:40:00 14.7 2.7 22.1 9.1 14.9 2.8 22.9 8.8 14.2 2.6 23.3 8 78 10 74 165 4.6 0 4.8 4.5 12/28/2005 06:50:00 15.9 2.1 21.4 11.1 16.2 2.1 22.1 11.1 15.2 1.9 20.2 11.1 85 9 89 165 4.6 0 4.8 4.5 12/28/2005 07:00:00 17 2.6 23.3 10.7 17.4 2.7 23.7 11.8 16.2 2.6 22.9 10.7 83 8 88 165 4.4 0 4.5 4.3 12/28/2005 07:10:00 16.4 2.1 22.1 11.5 16.6 2.1 22.6 11.1 15.5 2.2 22.1 9.9 84 9 92 165 4.4 0 4.5 4.3 12/28/2005 07:20:00 16.3 2.4 21.8 9.9 16.6 2.5 22.1 10.3 15.6 2.4 23.3 9.5 81 8 87 165 4.3 0 4.5 4.3 12/28/2005 07:30:00 14.9 2.2 20.6 10.7 15.3 2.3 21 10.3 14.4 2.2 20.6 9.5 80 9 72 165 4.3 0 4.5 4.3 12/28/2005 07:40:00 16.3 2.1 22.1 11.5 16.7 2.2 23.3 11.8 15.6 2.1 20.6 9.5 83 8 84 165 4.4 0 4.5 4.3 12/28/2005 07:50:00 17 2.3 24 10.3 17.3 2.4 24.8 10.3 16.1 2.3 22.1 11.1 83 8 79 165 4.5 0 4.8 4.5 12/28/2005 08:00:00 16.7 2.4 21.8 10.3 17.1 2.5 22.6 10.7 15.9 2.3 21.4 10.3 85 8 88 165 4.5 0 4.8 4.5 12/28/2005 08:10:00 16.4 2.2 21.4 11.1 16.8 2.2 21.8 11.1 15.6 2.3 21.4 10.7 85 8 92 165 4.6 0 4.8 4.5 12/28/2005 08:20:00 15.7 1.9 21.8 11.1 16.1 1.9 21.8 11.1 15.1 2 20.2 9.9 84 8 95 165 4.6 0 4.8 4.5 12/28/2005 08:30:00 17.7 2.8 24.8 10.7 18 2.8 25.2 11.1 16.9 2.5 23.3 11.1 86 9 93 165 4.6 0 4.8 4.5 12/28/2005 08:40:00 15.7 2.6 22.6 9.9 16 2.6 22.6 9.9 15 2.4 22.6 10.3 90 8 100 165 4.6 0 4.8 4.5 12/28/2005 08:50:00 16.1 1.8 21 11.1 16.4 1.9 21 10.7 15.3 1.9 20.2 11.1 86 7 84 165 4.7 0 4.8 4.8 12/28/2005 09:00:00 14.6 2.1 19.1 9.1 14.9 2.1 19.5 9.5 14 2 18.7 9.5 87 7 97 165 4.8 0 5 4.8 12/28/2005 09:10:00 15.4 2 20.2 10.3 15.8 2.1 20.6 10.3 14.7 2 19.9 9.1 87 8 91 165 4.9 0 5 4.8 12/28/2005 09:20:00 16.5 2.1 21.8 10.3 16.8 2.2 21.8 10.3 15.3 2.2 20.2 8.8 95 8 92 165 4.8 0 5 4.8 12/28/2005 09:30:00 16.1 1.6 21.4 11.1 16.4 1.7 21.8 11.8 15.1 1.7 19.5 10.3 97 7 92 165 4.7 0 5 4.8 12/28/2005 09:40:00 15.1 1.6 18.7 9.9 15.4 1.6 19.5 10.3 13.8 1.7 17.6 9.5 95 8 88 165 4.7 0 4.8 4.5 12/28/2005 09:50:00 16.2 2.3 21 9.5 16.5 2.3 21.4 9.1 15.1 2.2 20.6 8.4 97 7 99 165 4.6 0 4.8 4.5 12/28/2005 10:00:00 16.3 2.3 21 9.1 16.6 2.4 21.4 9.1 15.2 2.3 19.9 9.1 94 8 91 165 4.6 0 4.8 4.5 12/28/2005 10:10:00 15.1 1.7 19.1 10.7 15.3 1.8 19.9 11.1 14 2 18.7 9.5 99 8 98 165 4.4 0 4.5 4.3 12/28/2005 10:20:00 14.7 1.9 19.1 10.3 14.9 2 19.9 10.3 13.6 1.8 18.3 9.1 94 8 102 165 4.5 0 4.8 4.5 12/28/2005 10:30:00 13.5 2.3 18.7 7.6 13.7 2.4 19.1 7.2 12.7 2.4 19.1 6.5 91 9 90 165 4.6 0 4.8 4.5 12/28/2005 10:40:00 15.1 1.7 19.1 9.1 15.4 1.7 19.9 9.9 14.1 1.8 18.7 9.5 92 8 86 165 4.6 0 4.8 4.5 12/28/2005 10:50:00 14.3 2.2 21 9.5 14.5 2.2 21.4 9.1 13.2 2.2 20.2 8.4 92 8 102 165 4.6 0 4.8 4.5 12/28/2005 11:00:00 14.5 1.8 17.9 8.4 14.7 1.9 18.7 8.8 13.8 1.9 18.7 8 95 7 96 165 4.5 0 4.5 4.5 12/28/2005 11:10:00 13.9 1.7 17.9 9.9 14.2 1.8 18.3 9.5 13.2 1.7 17.6 8.4 85 9 79 165 4.4 0 4.5 4.3 12/28/2005 11:20:00 13.7 2 19.1 8.4 14 2.1 19.5 8.8 13 2 19.1 8.8 79 8 71 165 4.4 0 4.8 4.3 12/28/2005 11:30:00 14.3 1.7 18.3 9.5 14.5 1.7 19.1 9.9 13.4 1.7 17.2 9.5 83 9 89 165 4.6 0 4.8 4.5 12/28/2005 11:40:00 14.6 1.9 19.1 9.1 14.9 2 19.5 9.9 14.1 2 17.9 8.8 82 8 77 165 4.7 0 4.8 4.8 12/28/2005 11:50:00 14.2 1.8 18.3 9.5 14.5 1.9 18.3 9.5 13.7 1.7 17.9 8.8 83 8 77 165 4.8 0 5 4.8 12/28/2005 12:00:00 13 1.7 17.6 9.1 13.3 1.7 17.6 9.5 12.6 1.7 17.6 8 79 9 81 165 4.8 0 5 4.8 12/28/2005 12:10:00 13.9 1.9 19.1 9.5 14.1 2 19.5 9.9 13.2 1.8 17.9 9.1 80 8 78 165 4.7 0 4.8 4.8 12/28/2005 12:20:00 13 1.7 17.9 8.8 13.2 1.8 18.3 9.5 12.6 1.6 16.8 8.8 80 9 89 165 4.7 0 4.8 4.5 12/28/2005 12:30:00 13.7 1.9 19.9 9.5 14 2 20.2 9.5 13.2 1.8 19.9 8.8 76 8 77 165 4.6 0 4.8 4.5 12/28/2005 12:40:00 13.5 2 18.3 8 13.8 2.1 18.7 8 12.9 1.8 17.9 8.4 76 9 79 165 4.6 0 4.8 4.5 12/28/2005 12:50:00 14 1.8 18.3 9.5 14.2 1.9 18.3 8.4 13.3 1.7 17.9 8.8 78 9 79 165 4.7 0 4.8 4.8 12/28/2005 13:00:00 13.3 2.1 18.3 8 13.6 2.2 18.7 8.8 12.7 2.3 17.9 8.4 80 8 77 165 4.7 0 4.8 4.8 12/28/2005 13:10:00 9.8 1.9 14.9 5.3 10 2 15.3 5.3 9.3 1.9 14.5 4.9 92 12 84 165 4.7 0 4.8 4.5 12/28/2005 13:20:00 9.7 1.9 15.6 5.3 9.9 2 16.1 5.7 9.4 1.8 15.6 5.7 92 11 91 165 4.6 0 4.8 4.5 12/28/2005 13:30:00 11.6 1.3 16.1 8 11.9 1.4 16.8 8.4 10.9 1.5 15.6 7.2 96 8 99 165 4.6 0 4.8 4.5 12/28/2005 13:40:00 10.8 1.3 13.7 7.2 11.1 1.3 13.7 6.8 10.2 1.4 13 6.8 95 7 92 165 4.4 0 4.8 4.3 12/28/2005 13:50:00 10.7 1.3 14.1 6.8 11 1.3 14.1 7.6 10.2 1.4 13.7 6.8 94 8 98 165 4.1 0.1 4.5 4 12/28/2005 14:00:00 10.6 1.2 13.7 7.6 10.9 1.3 13.7 7.6 9.9 1.3 12.6 6.5 92 7 91 165 4 0 4.3 3.8 12/28/2005 14:10:00 9.2 1.1 11.5 5.7 9.4 1.2 11.8 6.1 8.7 1.1 11.1 5.7 90 8 91 165 4 0 4.3 3.8 12/28/2005 14:20:00 8.2 1.7 11.8 4.6 8.4 1.7 11.8 4.6 7.7 1.5 11.5 4.6 93 9 78 165 4 0 4.3 3.8 12/28/2005 14:30:00 8.2 1 10.7 4.9 8.4 1.1 10.7 5.3 7.8 1 10.7 4.6 94 10 84 165 4 0 4.3 3.8 12/28/2005 14:40:00 9.4 1 12.2 6.5 9.6 1.1 12.6 6.5 8.9 1.1 12.2 6.5 97 7 91 165 4 0 4.3 3.8 12/28/2005 14:50:00 9.2 1 11.1 6.1 9.4 1 11.5 6.5 8.7 1 11.1 6.1 92 6 85 165 3.8 0 4.3 3.5 12/28/2005 15:00:00 9.2 1.1 12.2 5.7 9.4 1.1 12.2 6.1 8.8 1.1 11.1 5.3 91 8 102 165 4 0 4.3 3.8 12/28/2005 15:10:00 9.1 1 12.2 6.1 9.3 1.1 12.2 6.5 8.6 1.1 10.7 5.7 84 6 84 165 4.1 0 4.3 4 12/28/2005 15:20:00 9 1.1 11.5 6.1 9.1 1.1 11.5 6.1 8.5 1.1 11.1 5.3 86 8 73 165 4.1 0 4.3 4 12/28/2005 15:30:00 8 1.2 11.1 4.2 8.1 1.3 11.5 4.2 7.8 1 10.3 4.9 75 8 80 165 4.1 0 4.3 4 12/28/2005 15:40:00 7.3 1.1 10.3 4.6 7.4 1.2 10.7 4.2 7 1.1 9.5 4.2 71 10 76 165 4.1 0 4.3 4 12/28/2005 15:50:00 8 1.3 11.5 4.9 8.1 1.3 11.8 4.9 7.8 1.3 11.8 4.2 74 11 87 165 4.1 0 4.3 4 12/28/2005 16:00:00 7.3 1.1 10.7 4.9 7.4 1.2 11.1 4.9 7.1 1.1 10.3 4.2 69 9 68 165 4 0 4.3 4 12/28/2005 16:10:00 8.1 1.2 11.1 5.3 8.2 1.2 11.1 5.3 7.8 1.1 11.5 4.9 69 9 65 165 4 0 4.3 3.8 12/28/2005 16:20:00 7.6 1.3 11.1 4.2 7.8 1.4 11.5 4.2 7.3 1.4 11.5 4.2 67 9 65 165 4 0 4.3 3.8 12/28/2005 16:30:00 7.8 1.3 11.5 4.6 8 1.3 11.5 4.9 7.5 1.2 10.7 4.9 70 9 63 165 4.1 0 4.3 4 12/28/2005 16:40:00 7.3 1 9.5 4.6 7.4 1.1 9.9 4.2 7 1.1 9.5 4.2 66 9 68 165 4.1 0 4.3 4.3 12/28/2005 16:50:00 7.5 1.5 11.8 4.2 7.5 1.6 12.2 4.2 7.2 1.5 11.8 3.8 72 11 81 165 4.1 0 4.5 4.3 12/28/2005 17:00:00 6.8 1.2 9.9 3.8 6.8 1.3 10.3 3.8 6.4 1.2 10.3 3.8 68 9 62 165 4.1 0 4.5 4 12/28/2005 17:10:00 6.3 0.9 8.8 4.2 6.4 0.9 9.1 4.2 6.2 1 9.1 4.2 68 9 71 165 4.1 0 4.3 4 12/28/2005 17:20:00 6.5 0.8 8.8 4.2 6.6 0.9 9.1 4.2 6.3 0.8 8.4 4.6 74 9 63 165 4.2 0 4.5 4.3 12/28/2005 17:30:00 7.2 1.3 9.9 4.2 7.4 1.4 10.3 4.6 7 1.2 9.5 3.8 75 9 75 165 4.4 0 4.5 4.3 12/28/2005 17:40:00 6.8 1.2 9.9 4.2 6.9 1.2 9.9 4.2 6.4 1.2 9.9 4.2 79 10 78 165 4.4 0 4.5 4.3 12/28/2005 17:50:00 8 0.7 10.3 6.1 8.1 0.7 10.3 5.7 7.5 0.8 9.9 4.9 95 6 91 165 4.5 0 4.8 4.5 12/28/2005 18:00:00 7.4 0.6 9.1 5.3 7.6 0.6 9.1 5.3 7.2 0.8 9.1 4.9 99 5 103 165 4.5 0 4.8 4.5 12/28/2005 18:10:00 7 0.7 8.8 4.2 7.1 0.7 8.8 4.9 6.7 0.9 8.4 4.2 97 5 98 165 4.5 0 4.5 4.5 12/28/2005 18:20:00 7.5 0.5 8.8 5.7 7.7 0.6 9.1 5.7 7.1 0.8 8.4 4.6 99 4 102 165 4.5 0 4.8 4.5 12/28/2005 18:30:00 8 1 10.3 4.9 8.1 1 10.3 4.6 7.6 1.1 10.3 4.6 95 6 96 165 4.5 0 4.8 4.5 12/28/2005 18:40:00 8.7 1 10.7 5.3 8.9 1 10.7 6.1 8.2 1.1 10.7 5.3 95 6 89 165 4.4 0 4.5 4.3 12/28/2005 18:50:00 8.3 0.6 9.9 6.5 8.6 0.7 10.7 6.5 8 0.8 9.9 5.7 89 5 90 165 4.4 0 4.5 4.5 12/28/2005 19:00:00 8.4 0.6 9.5 6.1 8.6 0.6 9.9 6.5 7.8 0.7 9.1 5.7 93 5 88 165 4.4 0 4.8 4.3 12/28/2005 19:10:00 7.7 0.6 9.1 5.3 7.9 0.7 9.5 5.3 7.5 0.7 9.1 4.9 90 5 92 165 4.4 0 4.5 4.3 12/28/2005 19:20:00 7.5 0.8 9.5 4.6 7.7 0.8 9.9 4.9 7.4 0.8 9.1 5.3 88 6 91 165 4.4 0 4.5 4.3 12/28/2005 19:30:00 6.9 0.8 8.4 5.3 7.1 0.8 8.8 4.9 6.8 0.8 8.4 4.6 80 6 91 165 4.3 0 4.5 4.3 12/28/2005 19:40:00 4.8 1 7.2 3 5 1 7.6 2.6 4.7 0.9 7.2 2.6 68 12 67 165 4.3 0 4.5 4.3 12/28/2005 19:50:00 5.6 1 9.1 3.8 5.7 1 9.1 3.8 5.5 1 8.4 3.4 62 11 54 165 4.4 0 4.5 4.3 12/28/2005 20:00:00 5.8 1.1 8.8 4.2 5.8 1.1 9.1 4.2 5.5 1 8.8 3.8 66 8 69 165 4 0 4.5 3.8 12/28/2005 20:10:00 5 0.8 6.8 3 5.1 0.8 7.2 3 4.9 0.8 6.8 3 57 11 67 165 4.1 0 4.3 4.3 12/28/2005 20:20:00 5.2 1.2 8 2.6 5.2 1.2 8.4 2.6 5 1.1 7.6 3 67 12 85 165 4.3 0 4.5 4.3 12/28/2005 20:30:00 4.9 0.8 6.8 3.4 5 0.7 6.8 3.4 4.7 0.7 6.5 3 65 10 63 165 4.3 0 4.5 4.3 12/28/2005 20:40:00 5.2 0.8 7.2 3.4 5.3 0.8 7.6 3.4 5 0.8 7.2 3 76 8 72 165 4.4 0 4.5 4.3 12/28/2005 20:50:00 4.6 0.8 6.8 2.6 4.7 0.8 6.8 2.6 4.5 0.7 6.5 2.6 75 9 74 165 4.4 0 4.5 4.3 12/28/2005 21:00:00 3.9 0.8 5.7 2.3 4 0.7 6.1 2.3 3.8 0.7 5.7 1.9 65 9 78 165 4.4 0 4.5 4.3 12/28/2005 21:10:00 3.2 0.5 4.9 1.9 3.4 0.5 4.9 2.3 3.1 0.6 4.6 1.5 58 12 77 165 4.4 0 4.5 4.3 12/28/2005 21:20:00 4 0.8 6.1 2.3 4.2 0.8 6.5 2.3 3.9 0.8 6.1 1.9 67 13 80 165 4.4 0 4.5 4.3 12/28/2005 21:30:00 4.5 0.9 6.1 2.3 4.6 0.9 6.5 2.3 4.4 1 6.8 1.9 58 8 57 165 4.3 0 4.5 4.3 12/28/2005 21:40:00 4.9 0.7 6.5 3 4.9 0.7 6.5 3.4 4.7 0.7 6.5 3 41 8 27 165 4.1 0 4.3 4 12/28/2005 21:50:00 4.5 1 6.8 2.6 4.5 1 6.8 2.6 4.3 0.9 6.5 1.9 46 7 49 165 4 0 4.3 3.8 12/28/2005 22:00:00 3 0.8 4.6 1.1 3 0.8 4.6 1.1 2.9 0.7 4.6 1.5 42 9 52 165 4.1 0 4.3 4 12/28/2005 22:10:00 2.5 0.5 4.2 1.1 2.5 0.5 4.2 1.5 2.5 0.5 3.8 1.5 34 11 43 165 4.1 0 4.3 4 12/28/2005 22:20:00 3 1.2 5.7 0.7 3.1 1.2 5.7 0.7 2.9 1.1 5.3 0.7 69 15 86 165 4.1 0 4.5 4 12/28/2005 22:30:00 5 0.6 6.5 3.4 5.2 0.6 6.5 3.8 4.5 0.6 6.1 2.6 104 9 102 165 4.3 0 4.5 4.3 12/28/2005 22:40:00 5.1 0.6 6.5 3 5.2 0.6 6.8 3 4.8 0.7 6.1 3.4 122 9 129 165 4.3 0 4.5 4.3 12/28/2005 22:50:00 5.7 0.6 7.2 3.8 5.9 0.6 7.2 3.8 5.6 0.6 7.2 3.4 131 7 119 165 4.3 0 4.5 4.3 12/28/2005 23:00:00 5.6 0.5 6.5 4.6 5.7 0.5 6.5 4.6 5.6 0.5 6.8 4.2 135 5 126 165 4.3 0 4.5 4.3 12/28/2005 23:10:00 5.9 0.4 6.8 4.9 5.8 0.4 6.8 4.9 5.9 0.4 6.8 4.6 148 4 150 165 4.3 0 4.5 4.3 12/28/2005 23:20:00 4.6 0.7 6.1 3.4 4.7 0.6 6.1 3.4 4.7 0.7 6.5 3.4 155 3 157 165 4.4 0 4.5 4.3 12/28/2005 23:30:00 4.4 0.5 5.7 3.4 4.5 0.5 6.1 3.4 4.3 0.5 6.1 2.6 146 8 136 165 4.4 0 4.5 4.3 12/28/2005 23:40:00 4.1 0.4 5.3 3.4 4.2 0.4 5.3 3.4 4.1 0.4 5.3 2.6 147 11 135 165 4.4 0 4.5 4.3 12/28/2005 23:50:00 5.1 0.3 5.7 3.8 5.2 0.3 5.7 4.6 5.1 0.4 5.7 4.2 143 5 136 165 4.3 0 4.5 4.3 12/29/2005 00:00:00 4.9 0.4 5.7 4.2 5.1 0.3 6.1 4.2 5.1 0.4 6.1 3.8 142 3 141 165 4.2 0 4.5 4.3 12/29/2005 00:10:00 5.7 0.4 6.5 4.6 5.9 0.4 6.5 4.9 5.8 0.4 6.8 4.6 143 3 137 165 4.1 0 4.5 4.3 12/29/2005 00:20:00 5.3 0.7 6.5 3.8 5.4 0.7 6.5 3.8 5.5 0.6 6.5 4.2 153 4 147 165 4.1 0 4.3 4 12/29/2005 00:30:00 4.5 0.5 5.3 3.4 4.6 0.5 5.7 3.4 4.8 0.5 5.7 3.8 159 4 159 165 4.1 0 4.3 4 12/29/2005 00:40:00 5.2 0.6 6.5 3.8 5.2 0.6 6.5 3.8 5.4 0.6 6.5 3.8 154 5 153 165 4.1 0 4.3 4.3 12/29/2005 00:50:00 4.7 0.6 6.1 3.4 4.6 0.5 6.1 3.8 4.9 0.5 6.5 3.8 165 4 162 165 4.1 0 4.3 4 12/29/2005 01:00:00 5.4 0.6 7.2 3.4 5.4 0.5 6.8 4.2 5.6 0.6 6.8 3.8 164 8 158 165 4 0 4.3 3.8 12/29/2005 01:10:00 7.2 0.7 9.1 5.3 7.1 0.7 9.1 5.3 7.4 0.7 9.1 5.7 158 4 153 165 3.9 0 4.3 3.8 12/29/2005 01:20:00 7.5 0.8 9.9 4.9 7.4 0.8 9.5 5.3 7.7 0.8 9.9 5.7 158 11 163 165 3.7 0 3.8 3.5 12/29/2005 01:30:00 7.8 0.9 9.5 5.7 7.7 0.9 9.5 5.7 7.9 0.9 9.9 5.7 163 10 166 165 3.6 0 3.8 3.5 12/29/2005 01:40:00 7.9 0.6 9.5 6.1 7.8 0.5 9.1 6.5 8.1 0.6 9.5 6.1 168 8 168 165 3.6 0 3.8 3.5 12/29/2005 01:50:00 8.2 0.6 9.5 6.5 7.9 0.5 9.5 6.8 8.3 0.6 9.5 6.5 169 12 164 165 3.6 0 3.8 3.5 12/29/2005 02:00:00 8.2 0.8 10.3 6.5 7.9 0.7 9.9 6.5 8.3 0.7 9.9 6.5 168 11 173 165 3.7 0 3.8 3.5 12/29/2005 02:10:00 7.5 0.8 9.5 5.3 7.2 0.8 9.1 5.3 7.6 0.8 9.5 5.7 169 6 184 165 3.7 0 3.8 3.5 12/29/2005 02:20:00 5.8 0.9 8 4.2 5.6 0.8 7.6 4.2 5.8 0.9 8 4.6 171 7 172 165 3.7 0 3.8 3.5 12/29/2005 02:30:00 5.3 0.6 6.8 3.8 5.3 0.6 6.8 3.4 5.5 0.5 6.5 4.2 157 8 156 165 3.8 0 3.8 3.5 12/29/2005 02:40:00 6.3 0.4 7.2 5.3 6.4 0.5 7.2 5.3 6.4 0.4 7.6 5.3 155 4 157 165 3.8 0 4 3.8 12/29/2005 02:50:00 6.8 0.2 7.2 6.1 6.8 0.2 7.2 6.1 6.8 0.3 7.2 5.7 154 2 154 165 3.8 0 4 3.8 12/29/2005 03:00:00 6.3 0.3 7.2 4.9 6.4 0.3 7.2 5.3 6.4 0.3 7.2 5.7 152 2 153 165 3.8 0 4 3.8 12/29/2005 03:10:00 6.2 0.4 6.8 5.3 6.2 0.3 7.2 5.3 6.2 0.4 7.2 5.3 146 3 145 165 3.8 0 4 3.8 12/29/2005 03:20:00 6.6 0.5 7.6 5.3 6.7 0.5 7.6 5.3 6.6 0.5 8 5.3 144 4 146 165 3.9 0 4 3.8 12/29/2005 03:30:00 6.2 0.5 7.2 4.9 6.2 0.5 7.2 4.9 6.3 0.5 7.2 4.9 154 3 151 165 4 0 4.3 3.8 12/29/2005 03:40:00 4.9 0.3 5.7 4.2 4.9 0.3 5.7 4.2 5 0.3 5.7 4.2 151 3 151 165 4 0 4.3 3.8 12/29/2005 03:50:00 5.3 0.4 6.1 4.6 5.3 0.3 6.5 4.6 5.5 0.4 6.5 4.6 152 2 149 165 4 0 4.3 3.8 12/29/2005 04:00:00 5.9 1 8 4.6 5.9 1 8 4.6 6.1 0.9 8 4.6 149 3 150 165 4 0 4.3 3.8 12/29/2005 04:10:00 11.2 2.1 14.5 7.2 11.1 2.1 14.5 6.8 11.1 2.1 14.9 7.6 148 6 160 165 4 0 4.3 3.8 12/29/2005 04:20:00 12.3 0.8 14.1 9.9 12.3 0.8 14.1 9.9 12.2 1 14.1 9.9 150 4 147 165 4 0 4.3 3.8 12/29/2005 04:30:00 12.1 0.7 13.3 10.3 12.2 0.7 13.7 10.3 12.1 0.9 14.1 9.9 150 3 153 165 3.9 0 4 3.8 12/29/2005 04:40:00 13.3 1.1 15.6 10.3 13.3 1.1 15.6 10.3 13.4 1.3 15.6 10.7 150 4 154 165 3.8 0.1 4.3 3.5 12/29/2005 04:50:00 13.1 0.9 15.6 11.1 13.2 0.9 16.1 11.1 13 1 15.6 11.1 148 3 151 165 3.6 0 3.8 3.5 12/29/2005 05:00:00 14.4 0.9 16.8 12.2 14.5 0.8 16.4 11.8 14.3 1 16.8 11.8 150 4 153 165 3.4 0 3.8 3.3 12/29/2005 05:10:00 11.8 1.5 14.9 8.8 11.9 1.5 15.3 8.8 11.8 1.6 14.9 8 152 5 156 165 3.3 0 3.5 3.3 12/29/2005 05:20:00 12.3 1.2 15.3 9.1 12.3 1.2 14.9 9.5 12.3 1.3 15.6 8.8 152 4 148 165 3.2 0.1 3.5 3 12/29/2005 05:30:00 10.8 0.6 12.2 8.8 10.8 0.6 12.2 9.1 10.8 0.8 12.6 8 150 5 161 165 3 0 3.3 3 12/29/2005 05:40:00 10.4 0.6 12.2 8.4 10.5 0.6 11.8 8.8 10.3 0.7 11.8 8 149 2 148 165 3 0 3.3 2.8 12/29/2005 05:50:00 9.3 0.8 11.1 6.5 9.3 0.8 11.5 7.2 9.3 0.8 11.1 6.8 153 5 157 165 3 0 3 2.8 12/29/2005 06:00:00 10.2 0.8 12.2 8 10.2 0.8 11.8 8 10 1 12.2 7.2 147 4 143 165 2.9 0 3.3 2.8 12/29/2005 06:10:00 11 0.7 13 8.8 11.1 0.6 12.6 8.4 11 0.8 13 8 146 4 147 165 2.7 0 3 2.6 12/29/2005 06:20:00 10.4 1.1 12.6 7.2 10.4 1.1 12.6 7.2 10.2 1.3 12.6 7.2 146 6 156 165 2.6 0 2.8 2.6 12/29/2005 06:30:00 9 0.7 10.3 7.2 9.1 0.7 10.3 7.2 8.8 1 10.7 6.1 146 5 154 165 2.7 0 2.8 2.6 12/29/2005 06:40:00 8.8 0.9 10.7 6.8 8.8 0.8 10.7 6.8 8.6 0.9 10.3 6.1 141 5 145 165 2.7 0 2.8 2.8 12/29/2005 06:50:00 7.4 0.7 9.5 5.7 7.4 0.7 9.1 5.7 7.2 0.7 9.5 5.3 141 8 150 165 2.7 0 2.8 2.6 12/29/2005 07:00:00 9.2 0.5 10.3 7.6 9.2 0.5 9.9 7.6 9.1 0.5 10.7 7.6 149 3 151 165 2.6 0.1 2.8 2.6 12/29/2005 07:10:00 7.6 0.6 9.5 6.1 7.7 0.6 9.1 6.1 7.4 0.7 9.1 5.7 145 5 145 165 2.4 0 2.6 2.3 12/29/2005 07:20:00 7.1 0.7 9.1 5.3 7.2 0.7 9.5 5.7 7 0.8 9.1 4.9 138 6 135 165 2.4 0 2.6 2.3 12/29/2005 07:30:00 7.2 0.7 8.8 5.7 7.4 0.7 9.1 5.7 7 0.8 9.5 4.9 135 7 148 165 2.5 0 2.6 2.6 12/29/2005 07:40:00 6.1 0.5 7.6 4.6 6.3 0.5 8 4.6 6 0.6 7.6 3.4 128 6 124 165 2.6 0 2.8 2.6 12/29/2005 07:50:00 7.3 0.5 8.4 5.7 7.5 0.5 8.4 6.1 7.2 0.6 8.4 4.6 123 4 112 165 2.7 0 2.8 2.6 12/29/2005 08:00:00 7.2 0.6 8.4 5.7 7.5 0.6 8.8 5.3 6.9 0.6 8 4.9 118 4 120 165 2.8 0 2.8 2.8 12/29/2005 08:10:00 7.6 0.5 9.1 6.1 7.9 0.5 9.5 6.1 7.2 0.7 8.8 4.9 110 4 106 165 2.9 0 2.8 2.8 12/29/2005 08:20:00 6.9 0.6 8.4 5.3 7.1 0.6 8.4 5.3 6.4 0.8 8.4 4.6 97 6 93 165 2.7 0 3 2.8 12/29/2005 08:30:00 7.5 0.7 9.1 5.3 7.7 0.7 9.5 5.7 7.1 0.8 9.1 4.9 86 5 91 165 2.7 0 2.8 2.6 12/29/2005 08:40:00 8.9 1.7 12.2 5.3 9.2 1.7 12.6 5.7 8.4 1.6 11.8 5.3 90 9 88 165 2.7 0 2.8 2.6 12/29/2005 08:50:00 9.2 1 11.5 6.1 9.4 1 11.8 6.5 8.9 1 11.5 6.1 97 8 94 165 3 0 3 2.8 12/29/2005 09:00:00 8.7 1.3 12.2 6.1 8.9 1.3 12.2 6.1 8.1 1.2 11.5 5.3 90 10 115 165 2.6 0.1 2.8 2.6 12/29/2005 09:10:00 9.4 1.6 14.5 6.1 9.6 1.6 14.5 6.1 8.9 1.5 12.6 5.3 84 8 84 165 2.8 0 3 2.6 12/29/2005 09:20:00 9.1 1.6 12.6 5.3 9.4 1.7 13 5.7 8.7 1.7 12.2 5.3 81 7 80 165 2.9 0 3.3 2.8 12/29/2005 09:30:00 9.9 1.3 13.7 6.5 10.1 1.4 13.7 6.5 9.5 1.2 13.3 6.5 80 8 66 165 3.2 0 3.5 3 12/29/2005 09:40:00 10.5 1.7 14.1 6.8 10.7 1.8 14.9 6.5 10 1.7 14.1 6.5 78 11 76 165 3.5 0.1 3.5 3.3 12/29/2005 09:50:00 11.8 2.2 17.2 7.2 12.1 2.2 17.6 7.2 11.3 2.1 16.1 6.5 84 9 78 165 3.6 0 3.8 3.5 12/29/2005 10:00:00 12.8 1.6 16.8 9.1 13.1 1.7 17.2 8.8 12.1 1.6 16.1 8.4 82 8 81 165 3.6 0 3.8 3.5 12/29/2005 10:10:00 11.7 1.6 15.3 7.6 11.9 1.7 15.6 7.6 11.3 1.7 15.3 6.8 81 8 84 165 3.7 0 3.8 3.5 12/29/2005 10:20:00 13.2 2.3 18.3 8.4 13.4 2.3 18.3 8.4 12.6 2.1 17.6 8 81 9 85 165 3.7 0 3.8 3.5 12/29/2005 10:30:00 13.1 1.8 17.2 8.8 13.4 1.8 17.2 8.8 12.4 1.7 16.1 8 86 8 91 165 3.6 0 3.8 3.5 12/29/2005 10:40:00 11.7 1.7 15.6 6.8 11.9 1.7 15.6 6.5 11.1 1.7 14.9 6.5 77 11 74 165 3.6 0 3.8 3.5 12/29/2005 10:50:00 9.9 1.7 14.9 5.3 10.1 1.8 15.6 5.7 9.7 1.7 15.3 6.5 72 10 85 165 3.7 0 3.8 3.5 12/29/2005 11:00:00 10.8 1.4 15.3 6.8 11 1.5 15.6 7.2 10.4 1.3 14.5 6.8 73 9 92 165 3.8 0 3.8 3.8 12/29/2005 11:10:00 10.1 1.7 14.1 6.1 10.3 1.8 14.1 6.5 9.7 1.7 13.7 5.7 73 12 84 165 3.8 0 4 3.8 12/29/2005 11:20:00 10.1 1.5 14.5 6.1 10.3 1.6 14.5 5.7 9.6 1.5 13.7 6.1 65 11 41 165 3.8 0 4 3.8 12/29/2005 11:30:00 9.9 1.7 14.1 5.7 10.1 1.8 14.5 4.9 9.6 1.7 14.1 4.9 64 11 75 165 4 0 4.3 3.8 12/29/2005 11:40:00 9.7 1.3 13.3 6.5 9.9 1.4 13.7 6.5 9.3 1.5 13 5.7 62 9 56 165 4 0 4.3 4 12/29/2005 11:50:00 10 1.7 14.5 6.5 10.2 1.9 14.9 6.1 9.6 1.7 14.1 5.7 68 10 74 165 4.1 0 4.3 4 12/29/2005 12:00:00 8.1 1.3 13.3 5.3 8.2 1.4 13.3 5.3 7.6 1.4 13.3 4.6 63 11 63 165 4.2 0 4.5 4.3 12/29/2005 12:10:00 9.1 1.7 13.3 5.7 9.3 1.8 13.3 5.7 8.6 1.7 12.6 4.6 71 11 85 165 4.3 0 4.5 4.3 12/29/2005 12:20:00 11 1.2 13.7 7.6 11.2 1.3 14.1 7.2 10.5 1.1 13.3 7.6 78 6 80 165 4.6 0 4.8 4.5 12/29/2005 12:30:00 11.7 1 13.7 8.4 12 1.1 14.1 8.4 11.1 1 13.7 8 83 7 87 165 4.8 0 5 4.5 12/29/2005 12:40:00 10.7 1 13.3 7.6 10.9 1.1 13.7 8 10.2 1.2 13.3 6.8 92 5 82 165 4.9 0 5 4.8 12/29/2005 12:50:00 10.4 0.9 13 6.8 10.6 0.9 13 7.6 9.6 1.2 11.8 6.8 99 6 102 165 5.1 0 5.2 5 12/29/2005 13:00:00 10.2 1 13 7.6 10.4 1 13.3 7.6 9.8 1.1 12.2 6.8 108 7 102 165 5.2 0 5.5 5 12/29/2005 13:10:00 9.2 1 11.5 6.1 9.3 1 11.5 6.1 8.8 1 11.1 6.1 116 7 116 165 5.3 0 5.5 5.2 12/29/2005 13:20:00 9.4 1.1 11.8 5.7 9.6 1.1 11.8 6.5 9 1 11.8 6.1 120 6 110 165 5.4 0 5.5 5.2 12/29/2005 13:30:00 9.2 1 11.5 6.1 9.4 1 11.5 6.5 9 1.1 11.5 5.7 128 9 129 165 5.4 0 5.5 5.2 12/29/2005 13:40:00 9.9 1 12.2 6.8 10 1 12.6 7.2 9.6 1.2 12.2 6.5 132 6 132 165 5.3 0 5.5 5.2 12/29/2005 13:50:00 9.1 0.9 11.5 6.5 9.2 0.9 11.1 6.5 8.9 0.9 11.1 6.1 133 7 128 165 5.2 0 5.5 5.2 12/29/2005 14:00:00 8.5 0.8 10.3 6.5 8.5 0.8 10.7 6.5 8.2 0.9 10.7 5.3 135 8 130 165 5.2 0 5.5 5.2 12/29/2005 14:10:00 8.7 0.9 10.7 6.5 8.9 0.9 10.7 6.5 8.7 1 11.5 6.1 130 8 132 165 5.2 0 5.5 5.2 12/29/2005 14:20:00 8.7 0.9 11.1 6.1 8.8 0.9 11.1 6.5 8.4 1 10.3 5.3 127 7 128 165 5.2 0 5.2 5 12/29/2005 14:30:00 9.2 0.9 11.5 6.8 9.3 1 11.8 6.5 8.9 1 12.2 6.5 128 6 120 165 5.1 0 5.2 5 12/29/2005 14:40:00 8.1 1 10.7 5.7 8.2 1 10.7 5.7 7.9 1 10.3 5.7 134 7 128 165 5.1 0 5.2 5 12/29/2005 14:50:00 7.7 0.8 9.9 5.3 7.8 0.8 9.9 5.3 7.6 0.8 9.5 5.3 134 7 137 165 5.1 0 5.2 5 12/29/2005 15:00:00 7.2 0.8 9.1 5.3 7.3 0.8 9.1 5.3 7.1 0.8 9.1 5.3 135 7 133 165 5.1 0 5.2 5 12/29/2005 15:10:00 7.3 0.6 9.5 5.7 7.4 0.6 9.5 5.7 7.3 0.6 8.8 5.7 131 6 129 165 5.1 0 5.2 5 12/29/2005 15:20:00 7.5 0.6 9.5 6.1 7.6 0.6 9.5 6.1 7.5 0.7 9.5 5.7 130 6 135 165 4.9 0 5 4.8 12/29/2005 15:30:00 7 0.6 9.1 5.3 7.1 0.6 8.8 4.9 6.9 0.6 8.8 5.3 129 6 135 165 4.9 0 5 4.8 12/29/2005 15:40:00 6.9 0.6 8 5.7 6.9 0.5 8.4 5.7 6.8 0.6 8 4.9 128 7 113 165 4.9 0 5 4.8 12/29/2005 15:50:00 6.7 0.6 8 4.6 6.8 0.6 8.4 4.9 6.6 0.6 8.4 4.9 132 8 127 165 4.9 0 5 4.8 12/29/2005 16:00:00 6.2 0.8 8 4.6 6.3 0.8 8 4.6 6.1 0.8 8 4.2 135 9 128 165 4.9 0 5 4.8 12/29/2005 16:10:00 8.1 2.1 14.1 5.3 8.2 2 14.1 5.3 7.9 1.7 13.3 4.9 134 9 135 165 4.9 0 5.2 4.8 12/29/2005 16:20:00 11.1 1.3 15.3 7.6 11.3 1.3 15.6 7.2 10.8 1.2 14.9 7.6 120 9 123 165 5.2 0 5.2 5 12/29/2005 16:30:00 11.5 1.5 15.3 7.2 11.6 1.5 15.3 7.2 11.3 1.4 14.9 7.6 120 8 121 165 4.8 0.1 5.2 4.5 12/29/2005 16:40:00 9.6 1.1 12.6 6.8 9.8 1.1 13 6.8 9.2 1.3 12.6 6.1 113 7 113 165 4.4 0.1 4.8 4.3 12/29/2005 16:50:00 10.2 1.2 12.6 7.2 10.4 1.2 13 7.2 9.6 1.4 13 6.5 111 5 107 165 3.8 0 4.3 3.5 12/29/2005 17:00:00 9.1 0.7 10.7 6.1 9.3 0.7 10.7 6.1 8.6 0.9 10.7 5.7 107 6 85 165 3.5 0 3.8 3.3 12/29/2005 17:10:00 6.6 1.2 9.5 3.4 6.8 1.1 9.5 3.8 6.3 1.2 9.9 3 109 7 109 165 3.2 0 3.5 3 12/29/2005 17:20:00 6 0.8 8.4 4.2 6.3 0.8 8.8 4.2 5.7 1 8.4 3.4 103 9 95 165 3.3 0.1 3.5 3 12/29/2005 17:30:00 9.5 1.7 13.7 5.7 9.7 1.7 14.1 6.1 9 1.9 13.7 4.6 97 9 109 165 3.9 0.1 4.3 3.5 12/29/2005 17:40:00 12.4 1.2 15.3 8.8 12.5 1.2 15.3 8.4 11.7 1.2 14.5 8 106 7 102 165 4.1 0 4.3 3.8 12/29/2005 17:50:00 11.3 1.6 16.1 7.2 11.6 1.6 16.4 7.2 10.9 1.6 15.6 6.8 115 8 116 165 4.1 0 4.3 4 12/29/2005 18:00:00 11.1 1.3 15.3 7.6 11.3 1.3 15.3 7.6 10.6 1.5 14.5 6.5 117 7 117 165 4.1 0 4.3 4 12/29/2005 18:10:00 11.7 1.5 15.3 8 11.9 1.5 15.6 8.4 10.9 1.5 15.3 7.2 114 8 112 165 4 0 4.3 4 12/29/2005 18:20:00 12.4 1.7 17.6 8.8 12.6 1.7 17.6 8.8 12 1.7 17.2 8.4 119 7 123 165 4 0 4.3 3.8 12/29/2005 18:30:00 11.5 1.5 15.6 7.6 11.7 1.5 16.1 7.6 10.9 1.5 15.3 7.2 114 7 94 165 4.1 0 4.3 4 12/29/2005 18:40:00 11.7 1.2 14.1 8 11.9 1.1 14.9 8 11.2 1.3 14.9 7.2 108 6 106 165 4.2 0 4.5 4.3 12/29/2005 18:50:00 13 1.6 17.2 8.8 13.2 1.7 17.6 9.1 12.4 1.8 16.8 8 110 8 105 165 4.3 0 4.5 4.3 12/29/2005 19:00:00 13.5 2.4 19.1 8.4 13.7 2.4 19.5 8.4 12.7 2.4 19.1 7.6 109 7 105 165 4.4 0 4.5 4.3 12/29/2005 19:10:00 15 1.7 19.1 10.3 15.3 1.8 19.5 11.1 13.9 1.9 18.7 9.5 112 8 106 165 4.3 0 4.5 4.3 12/29/2005 19:20:00 14.1 2.6 19.9 7.2 14.4 2.7 20.2 7.6 13.2 2.5 20.6 6.8 105 9 97 165 4.4 0 4.5 4.3 12/29/2005 19:30:00 15.1 1.5 19.5 10.7 15.4 1.7 19.9 11.1 14.1 1.8 19.9 9.9 97 7 100 165 4.3 0 4.5 4.3 12/29/2005 19:40:00 15.9 2.3 21 10.7 16.3 2.4 21.4 10.3 15.2 2.4 21.4 9.9 99 9 107 165 4.4 0 4.5 4.3 12/29/2005 19:50:00 15.1 1.8 19.5 9.9 15.4 1.8 20.2 9.5 14.3 1.8 18.3 9.9 100 8 105 165 4.4 0 4.5 4.3 12/29/2005 20:00:00 14.5 2.1 18.7 8.8 14.8 2.2 19.5 9.1 13.7 2.1 18.7 8.8 94 9 92 165 4.4 0 4.5 4.3 12/29/2005 20:10:00 14.4 2.1 19.5 9.5 14.7 2.2 20.2 9.9 13.4 2.2 17.9 7.6 96 8 107 165 4.2 0 4.5 4.3 12/29/2005 20:20:00 13.7 2.1 17.9 8 14 2.1 17.9 8 13.1 1.9 17.9 8 90 9 98 165 4.2 0 4.5 4.3 12/29/2005 20:30:00 14.7 1.9 18.7 9.5 15 2 19.1 9.5 13.8 1.7 17.9 9.5 87 8 89 165 4 0 4.3 3.8 12/29/2005 20:40:00 13.7 2.3 19.1 8.4 14 2.4 19.9 8.4 13.1 2.1 18.7 8.8 84 9 85 165 4 0 4.3 4 12/29/2005 20:50:00 13.6 2.2 18.7 8.4 13.9 2.3 19.5 8.4 12.9 2.1 18.7 8 86 10 91 165 4 0 4.3 3.8 12/29/2005 21:00:00 13.5 1.9 17.9 9.5 13.8 1.9 18.3 9.9 13.1 1.8 17.9 8.8 82 9 73 165 4 0 4.3 3.8 12/29/2005 21:10:00 12.4 2.2 19.1 7.6 12.7 2.3 19.5 8 12 2.1 17.9 7.6 78 10 81 165 4.1 0 4.3 4 12/29/2005 21:20:00 13.6 2.3 19.1 8.4 13.9 2.4 19.5 8.4 13 2.2 17.9 8.8 80 10 85 165 4.1 0 4.3 4 12/29/2005 21:30:00 13.9 2.2 19.9 8.8 14.2 2.3 20.6 8.4 13.6 2.2 20.2 8.8 83 8 79 165 4.1 0 4.3 4 12/29/2005 21:40:00 13.6 2.5 20.2 7.2 13.9 2.5 20.6 7.2 13.3 2.4 19.1 7.6 83 9 97 165 4.1 0 4.3 4.3 12/29/2005 21:50:00 13.6 2.5 18.7 8.8 13.9 2.5 18.7 8.8 13.2 2.4 19.9 8.8 82 9 83 165 4.1 0 4.3 4.3 12/29/2005 22:00:00 13.2 2.2 20.2 8.8 13.5 2.3 20.2 8.4 12.8 2.2 20.2 8 81 9 91 165 4.1 0 4.3 4 12/29/2005 22:10:00 15.4 1.9 19.9 9.5 15.8 1.9 20.2 9.1 14.8 1.9 19.1 8.4 83 8 77 165 4 0 4.3 4 12/29/2005 22:20:00 13.5 1.8 18.3 9.1 13.9 1.8 18.7 8.8 12.8 1.7 17.9 9.1 90 8 90 165 4 0 4.3 4 12/29/2005 22:30:00 14 2.3 20.2 8 14.3 2.4 20.6 8.4 13.3 2.2 19.9 8 87 8 89 165 4 0 4.3 3.8 12/29/2005 22:40:00 14.2 2.1 18.7 9.1 14.5 2.2 19.1 9.9 13.5 2 18.3 9.1 92 9 87 165 3.9 0 4.3 3.8 12/29/2005 22:50:00 14.3 2 19.5 9.5 14.6 2.1 20.2 9.1 13.6 1.7 18.7 10.3 88 9 89 165 3.9 0 4 3.8 12/29/2005 23:00:00 13.3 1.7 17.2 9.1 13.6 1.8 17.9 9.9 12.6 1.7 17.2 7.6 91 8 91 165 4 0 4.3 3.8 12/29/2005 23:10:00 13.2 2.4 19.1 7.6 13.5 2.5 19.5 8 12.6 2.3 18.7 7.6 83 9 96 165 4 0 4.3 3.8 12/29/2005 23:20:00 14.5 2 19.5 10.7 14.8 2 19.9 10.7 13.8 1.9 18.7 9.5 87 8 87 165 4 0 4.3 3.8 12/29/2005 23:30:00 12.8 1.7 17.2 8.8 13 1.7 17.6 8.8 12 1.7 17.6 8 89 8 90 165 4 0 4.3 3.8 12/29/2005 23:40:00 14.5 1.8 19.5 9.1 14.8 1.9 19.5 9.5 13.8 1.7 17.6 9.5 87 8 92 165 4.1 0 4.3 4 12/29/2005 23:50:00 12.5 2.6 20.2 6.8 12.8 2.7 20.6 6.8 11.9 2.5 19.5 6.8 90 10 82 165 4.1 0 4.3 4 12/30/2005 00:00:00 13.1 2.7 17.9 6.5 13.3 2.7 18.3 6.1 12.4 2.6 17.2 6.8 87 9 92 165 4.1 0 4.5 4.3 12/30/2005 00:10:00 15 1.9 19.5 10.7 15.3 2 19.5 10.3 14.3 2.1 18.7 9.5 87 8 81 165 4.1 0 4.3 4.3 12/30/2005 00:20:00 13.7 1.7 18.7 8 14 1.7 19.1 8.8 13 1.5 17.9 8.8 83 10 88 165 4.1 0 4.5 4.3 12/30/2005 00:30:00 14.7 1.9 19.5 10.7 15 2 20.2 10.7 14 1.9 18.7 9.5 86 8 87 165 4.2 0 4.5 4.3 12/30/2005 00:40:00 13.2 1.9 17.6 8.4 13.5 1.9 18.7 8.4 12.9 1.9 17.6 8.4 80 10 94 165 4.2 0 4.5 4.3 12/30/2005 00:50:00 14.5 2 19.9 8.8 14.8 2.1 20.2 9.9 13.8 1.8 17.6 9.1 84 8 92 165 4.1 0 4.3 4.3 12/30/2005 01:00:00 14.4 1.9 19.1 8.4 14.6 2 19.1 8.8 13.5 1.8 17.9 9.1 89 8 85 165 4.1 0 4.3 4 12/30/2005 01:10:00 13.2 1.6 16.8 8.8 13.5 1.7 17.9 8.8 12.6 1.7 16.8 7.2 83 8 94 165 4.1 0 4.3 4 12/30/2005 01:20:00 13 2 19.5 8.8 13.3 2 19.9 9.1 12.7 2 17.9 8.4 85 9 79 165 4.1 0 4.3 4.3 12/30/2005 01:30:00 12.9 1.8 19.9 8.8 13.2 1.9 19.9 8.8 12.4 1.7 17.6 7.6 84 9 88 165 4.1 0 4.3 4 12/30/2005 01:40:00 12.5 1.9 16.8 7.6 12.8 1.9 17.2 8 12 1.8 17.2 8 81 10 87 165 4.2 0 4.5 4.3 12/30/2005 01:50:00 12.8 2.2 19.5 9.1 13.1 2.3 19.9 9.5 12.5 2.1 20.2 8.4 79 9 88 165 4.1 0 4.5 4.3 12/30/2005 02:00:00 11 2.1 17.6 5.3 11.2 2.2 17.9 5.7 10.7 1.8 17.2 7.2 73 11 90 165 4.2 0 4.5 4.3 12/30/2005 02:10:00 12.6 2.6 19.1 6.8 12.9 2.6 19.9 7.2 12.2 2.4 19.1 6.8 82 10 81 165 4.2 0 4.5 4.3 12/30/2005 02:20:00 12 2.1 16.8 7.2 12.2 2.2 17.2 6.8 11.5 2 16.1 7.6 72 11 78 165 4 0 4.5 3.8 12/30/2005 02:30:00 12.4 2.2 18.7 7.6 12.6 2.3 19.1 8 12 2 16.8 7.6 73 9 56 165 4 0 4.3 3.8 12/30/2005 02:40:00 13 2.2 19.5 8 13.3 2.3 19.9 8 12.6 2 17.9 7.6 71 11 83 165 4 0 4.3 3.8 12/30/2005 02:50:00 10.7 2.1 17.2 6.5 10.9 2.3 17.9 6.5 10.4 2 16.8 6.5 64 12 77 165 4 0 4.3 3.8 12/30/2005 03:00:00 11.4 2 16.4 6.8 11.6 2.1 16.8 6.1 11 1.9 15.3 6.5 64 9 58 165 3.9 0 4 3.8 12/30/2005 03:10:00 11.5 1.6 15.6 8 11.7 1.7 16.1 8 11.1 1.7 16.4 7.2 68 8 81 165 3.8 0 4 3.8 12/30/2005 03:20:00 11 2.1 16.4 6.5 11.2 2.2 16.8 6.5 10.5 2.1 15.3 6.5 54 11 61 165 4 0 4 3.8 12/30/2005 03:30:00 11.2 1.9 15.6 6.5 11.3 2 16.4 6.1 10.9 1.9 15.3 5.7 63 12 62 165 3.8 0 4 3.8 12/30/2005 03:40:00 11.5 2.1 17.9 6.8 11.7 2.2 17.9 6.8 11 2 16.8 7.2 60 11 70 165 3.8 0 3.8 3.5 12/30/2005 03:50:00 12 1.9 19.5 7.6 12.2 2 19.9 8 11.7 1.9 17.9 6.8 65 13 64 165 3.8 0 3.8 3.8 12/30/2005 04:00:00 9.8 1.9 14.5 5.7 10 2 14.9 5.7 9.5 1.9 14.5 4.9 57 12 80 165 3.8 0 3.8 3.8 12/30/2005 04:10:00 11.4 2.3 16.8 6.8 11.6 2.5 17.2 6.5 11 2.2 16.8 5.7 60 11 77 165 3.7 0 3.8 3.5 12/30/2005 04:20:00 12.3 2.2 17.9 7.2 12.4 2.3 18.3 7.6 11.5 2.1 16.8 7.6 55 11 63 165 3.8 0 4 3.5 12/30/2005 04:30:00 11.3 2.4 16.8 6.1 11.5 2.4 16.8 6.1 10.9 2.2 16.4 6.1 55 11 70 165 3.8 0 3.8 3.5 12/30/2005 04:40:00 10.2 2.6 16.1 5.3 10.2 2.7 16.4 4.6 9.6 2.6 16.4 4.9 47 12 36 165 3.8 0 4 3.8 12/30/2005 04:50:00 12.1 2.1 17.6 6.8 12.2 2.2 17.9 6.8 11.4 2.2 17.9 6.5 51 12 54 165 3.6 0 3.8 3.5 12/30/2005 05:00:00 12.5 2.2 20.2 8 12.5 2.3 20.2 7.6 12.1 2.2 20.2 7.2 42 12 36 165 3.6 0 3.8 3.5 12/30/2005 05:10:00 12.4 2.1 19.9 6.8 12.4 2.1 19.1 6.8 12 2 18.7 6.1 44 11 57 165 3.6 0 3.8 3.5 12/30/2005 05:20:00 11.6 2.4 17.6 6.5 11.7 2.5 17.9 6.1 11.1 2.2 16.8 6.5 49 11 39 165 3.6 0 3.8 3.5 12/30/2005 05:30:00 13 2.7 18.7 6.5 12.8 2.7 17.9 6.5 12.4 2.7 18.3 6.1 34 9 41 165 3.6 0 3.8 3.5 12/30/2005 05:40:00 13.2 2.2 20.2 8 13.2 2.3 20.6 7.2 12.7 2.3 20.6 7.6 36 8 42 165 3.6 0 3.8 3.5 12/30/2005 05:50:00 12.1 2 17.2 8 12 2.1 17.6 7.6 11.5 2.1 17.2 5.7 36 9 32 165 3.6 0 3.5 3.5 12/30/2005 06:00:00 14.1 2 18.3 8.8 14.1 2.1 19.1 8.8 13.7 2.1 19.1 8.8 40 9 42 165 3.5 0 3.8 3.3 12/30/2005 06:10:00 12 2 16.4 6.5 11.9 2.1 16.8 6.5 11.5 2.1 16.8 6.5 36 9 45 165 3.5 0 3.5 3.3 12/30/2005 06:20:00 12.9 1.9 17.6 8 12.8 2 18.3 8 12.5 2 17.6 7.6 35 9 48 165 3.4 0 3.5 3.3 12/30/2005 06:30:00 13.8 1.9 18.3 8 13.6 2.1 18.3 8 13.2 1.9 18.7 6.5 31 8 34 165 3.3 0 3.5 3.3 12/30/2005 06:40:00 14 2.1 20.6 8.4 13.8 2.2 20.2 7.6 13.4 2.1 18.7 8 30 9 28 165 3.3 0 3.5 3.3 12/30/2005 06:50:00 13 1.6 16.8 9.1 12.8 1.7 16.8 8.8 12.5 1.6 17.2 8 29 8 19 165 3.3 0 3.5 3.3 12/30/2005 07:00:00 13.9 2.1 19.1 8.8 13.7 2.2 19.1 8.4 13.6 2 18.7 8.4 28 9 33 165 3.2 0.1 3.5 3 12/30/2005 07:10:00 13.9 2.4 19.9 8.4 13.3 2.5 19.9 8 13.3 2.3 18.7 8.4 22 8 37 165 3 0 3.3 2.8 12/30/2005 07:20:00 11.7 1.5 16.1 8.8 10 2.1 16.1 6.1 11.2 1.6 16.4 7.2 11 8 22 165 3 0 3 2.8 12/30/2005 07:30:00 11.3 1.7 16.4 7.6 10.2 1.9 15.3 6.1 10.8 1.7 15.6 7.6 14 10 5 165 2.9 0 3 2.8 12/30/2005 07:40:00 13.5 1.5 16.4 9.9 11.8 1.7 16.8 7.2 13 1.5 17.2 9.1 13 7 19 165 3 0 3 2.8 12/30/2005 07:50:00 14 1.6 18.3 8.4 12 2.2 17.2 6.8 13.4 1.7 18.7 8.8 11 7 14 165 2.9 0 3 2.8 12/30/2005 08:00:00 14.6 1.8 20.6 9.5 12.1 2.3 17.9 7.2 14.1 1.9 19.5 9.1 9 8 11 165 2.9 0 3 2.8 12/30/2005 08:10:00 15.1 1.9 19.9 10.7 13.1 2.5 20.2 7.6 14.3 1.8 19.5 9.5 12 8 27 165 3 0 3 2.8 12/30/2005 08:20:00 15.8 2.1 21.8 10.7 14.1 2.6 21.4 8.8 15.3 2.2 20.2 10.7 13 8 20 165 2.9 0 3 2.8 12/30/2005 08:30:00 15.6 2.1 20.6 11.1 12 2.3 18.3 7.6 15.1 2.2 20.6 10.3 5 8 1 165 2.7 0 3 2.6 12/30/2005 08:40:00 16.2 1.7 20.6 12.2 12.7 2.3 19.9 8 16 1.7 19.9 11.1 7 8 16 165 2.7 0 2.8 2.6 12/30/2005 08:50:00 15.5 2.3 22.6 11.1 11.8 2.8 22.1 7.2 15.3 2.3 22.6 10.7 5 8 27 165 2.7 0 2.8 2.6 12/30/2005 09:00:00 14.7 1.6 19.1 10.3 11 2 16.4 6.5 14.7 1.7 19.1 10.3 2 8 351 165 2.6 0 2.8 2.6 12/30/2005 09:10:00 14.3 1.7 17.9 9.5 11.2 2.2 17.2 6.5 14.1 1.7 19.1 9.9 6 9 16 165 2.6 0 2.8 2.6 12/30/2005 09:20:00 16.2 2.1 21.4 10.7 13.5 3.1 21.4 7.2 15.8 2 20.2 9.9 0 12 353 165 2.4 0 2.8 2.3 12/30/2005 09:30:00 15.4 2.6 23.3 9.1 12 2.7 22.9 7.2 15 2.7 23.3 9.1 359 8 3 165 2.4 0 2.8 2.3 12/30/2005 09:40:00 16.7 2.5 22.9 8.4 13.7 3.2 22.1 7.6 16 2.6 22.9 8.4 356 10 10 165 2.4 0 2.6 2.3 12/30/2005 09:50:00 18.6 2.6 26 12.2 13.8 3.1 24 8 18.5 2.7 27.1 11.8 358 8 0 165 2.4 0 2.6 2.3 12/30/2005 10:00:00 18.8 2.8 26.3 11.8 15.3 3.5 24.8 9.5 18.3 3.1 25.2 8 357 9 354 165 2.4 0 2.6 2.3 12/30/2005 10:10:00 20.7 2.3 26.3 15.3 14.9 2.6 26 10.7 20.2 2.4 26.8 13.3 359 7 14 165 2.4 0 2.6 2.3 12/30/2005 10:20:00 19.2 2.6 25.6 13 14.7 2.8 22.1 8.4 18.7 2.6 25.2 10.7 357 7 358 165 2.3 0 2.6 2.1 12/30/2005 10:30:00 18.6 2.6 25.6 12.6 15.3 2.9 22.6 8.8 18.1 3.1 27.1 11.1 355 9 10 165 2.1 0 2.3 1.8 12/30/2005 10:40:00 18 2 24.4 13.3 13.7 2.5 19.9 8.8 17.7 2.3 22.9 12.2 357 7 1 165 1.9 0 2.1 1.8 12/30/2005 10:50:00 16.6 1.8 22.1 12.2 13.7 2.8 20.6 8 16.5 2.3 24.4 10.3 358 9 358 165 1.9 0 2.1 1.8 12/30/2005 11:00:00 16.1 1.9 22.6 10.3 13.7 2.6 21.8 8 16.5 2.3 23.7 11.1 356 9 353 165 1.9 0 1.8 1.8 12/30/2005 11:10:00 15.8 1.9 21 9.9 13.1 2.6 21.4 8.4 16.1 2.2 22.6 9.9 355 9 1 165 1.9 0 2.1 1.8 12/30/2005 11:20:00 17.1 2.4 23.7 12.2 13.3 2.6 20.2 8 16.6 2.3 23.3 11.8 357 8 1 165 1.9 0 2.3 1.8 12/30/2005 11:30:00 17 1.9 22.6 12.6 13.7 2.9 21.8 8.8 15.2 1.9 19.5 10.7 355 8 351 165 1.9 0 2.1 1.8 12/30/2005 11:40:00 17.1 2.3 22.1 11.1 13.4 2.4 20.6 7.6 15.3 2.2 20.6 9.1 355 8 357 165 2 0 2.3 1.8 12/30/2005 11:50:00 16.7 2.5 24 11.1 12.6 2.9 21.8 7.2 15.4 2.4 22.6 9.9 359 9 341 165 2 0 2.3 1.8 12/30/2005 12:00:00 17 2.2 22.9 11.5 12.7 2.3 20.2 6.8 16.1 2.3 21.8 10.7 359 7 349 165 2.2 0 2.3 2.1 12/30/2005 12:10:00 17.7 2.5 25.2 13.3 13.4 2.8 22.6 8.4 16.9 2.4 23.7 12.2 357 8 2 165 2.3 0.1 2.6 2.3 12/30/2005 12:20:00 17.8 2.4 24.4 12.6 13.4 2.2 20.6 8.4 17 2.4 24.4 10.3 357 8 358 165 2.6 0 2.8 2.6 12/30/2005 12:30:00 17.4 2.2 26 12.2 14.1 2.6 21.4 9.5 16.8 2.4 24.8 10.7 357 9 355 165 2.8 0.1 3 2.6 12/30/2005 12:40:00 17.3 2.7 23.3 11.5 12.9 2.7 22.9 7.2 16.9 2.5 22.9 11.5 357 7 356 165 3.1 0 3.3 2.8 12/30/2005 12:50:00 15.7 2.1 21.4 10.3 12.9 2.6 20.2 8 15.2 2.1 20.2 9.9 7 11 16 165 3.6 0.2 4 3.3 12/30/2005 13:00:00 15.9 2.6 21.8 9.5 14.1 3.1 21.4 6.5 15 2.6 22.6 8.8 13 8 15 165 4.3 0 4.5 4 12/30/2005 13:10:00 14.1 2.2 19.5 8.4 12.8 2.4 18.7 7.2 13.7 2.1 19.9 7.2 17 10 19 165 4.4 0 4.8 4.3 12/30/2005 13:20:00 15 2.2 21 9.9 14.1 2.4 21 9.1 14.1 2.2 20.2 8.4 20 9 22 165 4.7 0 4.8 4.5 12/30/2005 13:30:00 13.7 2.3 19.9 8 13.4 2.3 19.9 8 12.9 2.2 18.7 8.4 29 10 22 165 4.6 0 4.8 4.5 12/30/2005 13:40:00 11.1 1.5 14.9 7.6 10.8 1.6 14.9 7.2 10.7 1.5 16.1 7.2 29 9 37 165 4.6 0 4.8 4.5 12/30/2005 13:50:00 11.9 1.8 15.6 6.8 11.6 1.9 15.6 6.8 11.1 1.7 14.9 6.8 29 9 29 165 4.7 0 4.8 4.5 12/30/2005 14:00:00 13.3 1.7 17.6 8.4 13 1.8 17.9 8.4 12.6 1.8 17.9 8.8 28 8 39 165 4.7 0 4.8 4.8 12/30/2005 14:10:00 13.1 1.8 17.9 8.4 12.5 1.9 17.6 8 12.5 1.9 17.2 8 21 9 28 165 4.7 0 5 4.8 12/30/2005 14:20:00 13.4 2 17.6 8.4 13.1 2.1 17.2 8.4 12.7 2 17.9 7.6 26 9 20 165 4.8 0 5 4.8 12/30/2005 14:30:00 11.9 2 16.8 6.5 11.7 2.1 16.8 6.1 11.4 2.1 16.4 7.2 30 10 34 165 4.9 0 5 4.8 12/30/2005 14:40:00 10.9 1.7 15.3 6.5 10.7 1.7 15.6 6.1 10.3 1.6 14.5 6.5 34 10 37 165 4.9 0 5 4.8 12/30/2005 14:50:00 10.9 2.2 16.4 5.7 10.9 2.2 16.1 5.7 10.3 2.3 16.4 4.9 46 13 38 165 4.8 0.1 5 4.8 12/30/2005 15:00:00 9.2 1.7 13.3 5.3 9.2 1.8 14.1 4.9 8.8 1.7 13.7 4.9 45 11 32 165 4.7 0 4.8 4.5 12/30/2005 15:10:00 9 1.5 14.1 4.9 9 1.5 14.5 4.2 8.7 1.5 13.3 4.9 42 11 46 165 4.6 0 4.8 4.5 12/30/2005 15:20:00 8.9 1.5 13.3 4.9 8.8 1.6 13.7 4.6 8.4 1.6 14.9 4.6 42 13 78 165 4.6 0 4.8 4.5 12/30/2005 15:30:00 9 1.3 12.2 4.9 8.9 1.3 12.6 4.9 8.6 1.3 12.6 5.7 37 9 51 165 4.7 0 4.8 4.5 12/30/2005 15:40:00 10.3 1.3 13.7 6.5 10.2 1.4 13.3 6.1 9.9 1.4 13.7 6.1 36 9 32 165 4.7 0 4.8 4.5 12/30/2005 15:50:00 9.4 1.8 13.7 4.6 9.3 1.9 13.3 4.6 8.9 1.9 13.7 4.6 35 9 42 165 4.7 0 5 4.8 12/30/2005 16:00:00 9.9 1.7 14.5 6.1 9.7 1.7 14.5 4.9 9.2 1.5 13 5.7 38 10 25 165 4.8 0 5 4.8 12/30/2005 16:10:00 11.4 1.8 17.6 7.6 11.2 1.9 17.6 5.7 10.9 1.7 17.6 7.2 35 10 41 165 4.9 0 5 4.8 12/30/2005 16:20:00 10.7 1.7 15.6 6.8 10.6 1.7 15.6 6.8 10.2 1.7 14.9 5.7 38 10 30 165 4.9 0 5 4.8 12/30/2005 16:30:00 10.3 1.8 16.1 4.9 10.3 1.8 16.4 4.9 9.8 1.9 15.6 5.7 42 13 56 165 4.8 0 5 4.8 12/30/2005 16:40:00 10.8 2.1 15.3 5.3 10.9 2.1 15.6 4.9 10.1 2 14.9 6.1 47 11 50 165 4.7 0 5 4.5 12/30/2005 16:50:00 10.2 2.1 16.1 4.9 10.2 2.1 16.1 4.9 9.8 2.1 16.1 4.9 47 12 48 165 4.6 0 4.8 4.5 12/30/2005 17:00:00 10.4 2.2 15.3 5.7 10.4 2.2 15.3 5.3 9.9 2 15.6 5.7 45 12 44 165 4.6 0 4.8 4.5 12/30/2005 17:10:00 10.6 2.1 16.1 5.3 10.7 2.2 16.4 5.7 10.1 2 15.6 6.5 52 12 60 165 4.5 0 4.8 4.5 12/30/2005 17:20:00 10.2 2.1 16.4 5.7 10.3 2.1 16.4 6.1 9.8 1.9 15.6 5.7 53 11 47 165 4.5 0 4.5 4.5 12/30/2005 17:30:00 10.6 2.2 16.4 5.7 10.7 2.3 17.2 5.7 10 2.2 16.1 4.6 58 12 54 165 4.4 0 4.5 4.3 12/30/2005 17:40:00 9.8 2.2 14.9 4.9 9.9 2.3 14.9 4.9 9.2 2.1 14.9 4.2 54 15 29 165 4.4 0 4.5 4.3 12/30/2005 17:50:00 9.1 1.9 15.6 5.3 9.2 1.9 16.4 4.9 9 1.8 15.3 5.3 55 11 54 165 4.4 0 4.5 4.3 12/30/2005 18:00:00 11.5 2.1 16.4 6.5 11.7 2.3 16.8 6.1 11.2 1.9 16.1 6.8 64 8 68 165 4.1 0.1 4.5 4 12/30/2005 18:10:00 8.6 1.7 12.2 4.6 8.7 1.7 12.6 4.6 8.5 1.7 13 4.9 63 12 68 165 4.1 0 4.3 4.3 12/30/2005 18:20:00 11.5 1.8 17.9 6.8 11.7 1.9 17.9 7.2 11.1 1.9 16.1 6.8 71 10 73 165 4.1 0 4.5 4.3 12/30/2005 18:30:00 10.7 2 16.1 6.1 10.9 2.1 16.4 6.5 10.2 1.9 15.3 6.1 66 12 65 165 4.1 0 4.3 4 12/30/2005 18:40:00 11.7 1.7 15.6 8.4 11.9 1.7 16.1 7.6 11.4 1.6 16.4 7.2 66 9 61 165 4 0 4.3 4 12/30/2005 18:50:00 12.6 2 17.9 8 12.8 2.1 18.3 8 12.2 1.9 17.2 8 67 9 81 165 4 0 4.3 3.8 12/30/2005 19:00:00 11.5 2.3 17.6 7.2 11.7 2.4 17.9 6.8 11.1 2.2 17.6 7.2 72 9 66 165 3.9 0 4 3.8 12/30/2005 19:10:00 12.9 1.8 17.9 9.1 13.1 2 18.3 9.1 12.3 1.9 16.8 7.2 71 10 74 165 3.9 0 4 3.8 12/30/2005 19:20:00 12 2 17.6 6.5 12.2 2.1 17.9 7.2 11.8 1.9 17.2 7.6 71 11 78 165 4 0 4.3 3.8 12/30/2005 19:30:00 11.6 1.9 16.4 6.8 11.8 2 16.8 6.8 11.1 1.8 16.4 6.5 71 10 69 165 4 0 4.3 3.8 12/30/2005 19:40:00 11.1 1.9 16.4 6.1 11.3 2 16.8 6.1 10.8 1.7 16.4 5.3 71 11 73 165 4 0 4.3 4 12/30/2005 19:50:00 11.5 1.7 15.3 7.6 11.7 1.7 16.1 7.6 11.1 1.6 14.9 6.8 72 10 49 165 4.1 0 4.3 4 12/30/2005 20:00:00 11.2 1.5 16.1 7.2 11.4 1.7 16.1 7.2 10.7 1.7 14.5 6.5 78 9 88 165 4 0 4.3 4 12/30/2005 20:10:00 12.4 2.1 18.3 8 12.6 2.2 18.7 8.4 12 2.1 18.7 7.6 79 9 85 165 4 0 4.3 3.8 12/30/2005 20:20:00 13.4 1.9 19.1 8.8 13.7 1.9 18.7 9.5 12.9 1.8 18.7 8.8 81 9 92 165 4 0 4.3 3.8 12/30/2005 20:30:00 12.9 1.9 17.6 8.8 13.1 2 18.3 8.8 12.3 2 17.2 8.4 81 8 74 165 4 0 4.3 3.8 12/30/2005 20:40:00 12.4 1.9 17.6 7.2 12.7 2 18.3 7.6 12 1.8 17.6 7.6 83 8 77 165 3.8 0 4 3.8 12/30/2005 20:50:00 13.3 2.3 18.3 8.4 13.6 2.4 18.7 9.1 12.7 2.2 18.3 8 84 8 77 165 3.8 0 4 3.5 12/30/2005 21:00:00 12.6 1.7 17.6 8.4 12.9 1.7 18.3 8.4 12.1 1.8 17.9 8 83 9 81 165 3.7 0 3.8 3.5 12/30/2005 21:10:00 13.7 1.6 17.9 9.5 14 1.7 17.9 9.5 13.2 1.7 17.6 9.5 85 8 84 165 3.6 0 3.8 3.5 12/30/2005 21:20:00 13.2 1.7 16.8 8.8 13.6 1.8 17.6 9.1 12.8 1.7 17.9 8.4 84 8 80 165 3.6 0 3.8 3.5 12/30/2005 21:30:00 13.2 2 17.9 8.4 13.4 2.1 18.3 8.4 12.7 1.9 17.2 8 85 8 98 165 3.7 0 3.8 3.5 12/30/2005 21:40:00 13.2 1.5 17.6 9.1 13.6 1.5 17.9 8.8 13 1.5 16.8 8.4 87 7 94 165 3.8 0 3.8 3.5 12/30/2005 21:50:00 13.1 1.7 16.8 9.5 13.4 1.8 17.2 9.1 12.5 1.8 16.4 8.4 86 8 85 165 3.8 0 4 3.8 12/30/2005 22:00:00 13.9 1.7 17.2 9.1 14.2 1.7 17.6 9.1 13.2 1.8 17.6 8.4 86 7 84 165 3.8 0 4 3.8 12/30/2005 22:10:00 14.1 1.6 17.6 10.3 14.4 1.7 17.9 10.3 13.4 1.5 17.6 9.1 90 8 92 165 3.8 0 4 3.8 12/30/2005 22:20:00 12.9 1.9 17.6 8 13.2 1.9 17.9 8.4 12.1 1.7 16.1 8 94 8 94 165 3.9 0 4 3.8 12/30/2005 22:30:00 12.8 1.4 17.2 8.4 13.1 1.5 17.2 8 12.1 1.4 16.1 7.6 96 7 94 165 3.9 0 4 3.8 12/30/2005 22:40:00 13.1 1.9 17.2 8.8 13.3 1.9 17.6 8.4 12.1 1.9 16.1 8.4 95 7 88 165 4 0 4.3 3.8 12/30/2005 22:50:00 13.1 1.3 16.1 9.1 13.4 1.3 16.4 9.9 12.2 1.3 15.6 8.8 96 6 90 165 4 0 4.3 3.8 12/30/2005 23:00:00 13.2 1.5 17.2 9.5 13.4 1.5 17.6 9.5 12.2 1.7 16.8 8 99 6 102 165 3.9 0 4 3.8 12/30/2005 23:10:00 12.5 1.4 16.4 8.4 12.8 1.4 16.4 8.8 11.7 1.5 15.3 7.6 96 7 102 165 4 0 4.3 3.8 12/30/2005 23:20:00 13 1.2 15.6 9.5 13.2 1.2 16.1 8.8 12.3 1.3 16.1 8.4 96 6 100 165 3.8 0 4.3 3.8 12/30/2005 23:30:00 13.6 1.5 17.6 9.1 13.9 1.5 17.9 9.1 12.6 1.6 16.4 8 97 6 96 165 3.9 0 4 3.8 12/30/2005 23:40:00 13.2 1.5 16.4 8.8 13.4 1.5 16.4 8.8 12.2 1.5 16.1 7.6 97 7 91 165 3.9 0 4 3.8 12/30/2005 23:50:00 12.2 1.2 15.3 8.4 12.4 1.3 14.9 8.4 11.6 1.3 14.5 7.6 98 7 98 165 3.9 0 4 3.8 12/31/2005 00:00:00 12.2 1.5 15.3 8 12.4 1.5 15.6 8.4 11.4 1.6 15.3 7.6 100 7 102 165 4 0 4.3 3.8 12/31/2005 00:10:00 13.2 1.3 16.4 8.8 13.5 1.4 16.8 8 12.4 1.5 16.1 8.8 99 6 94 165 4 0 4.3 3.8 12/31/2005 00:20:00 11.8 1.6 14.9 7.2 12 1.7 15.3 7.2 10.8 1.5 14.5 6.8 99 8 105 165 3.9 0 4 3.8 12/31/2005 00:30:00 12 1.5 15.6 7.6 12.2 1.6 16.1 7.6 11.1 1.7 15.6 6.8 101 7 94 165 3.8 0 4 3.8 12/31/2005 00:40:00 11.8 1.5 14.9 7.2 12 1.5 15.6 7.2 11 1.5 14.5 6.8 102 6 102 165 3.8 0 4.3 3.8 12/31/2005 00:50:00 11.7 1.1 14.1 8.8 11.9 1.2 14.5 8.8 10.8 1.3 13.7 7.6 98 6 102 165 3.7 0 4 3.5 12/31/2005 01:00:00 11.6 1 14.1 8 11.9 1.1 14.1 8 10.8 1.2 13.3 6.8 99 5 98 165 3.5 0 3.8 3.3 12/31/2005 01:10:00 11.4 1.2 13.7 8.4 11.6 1.2 14.1 8 10.8 1.2 13.3 6.8 102 5 102 165 3.5 0 3.5 3.3 12/31/2005 01:20:00 11.8 1 13.7 9.1 12.1 1 13.7 9.1 11.3 1.2 14.1 7.6 107 4 102 165 3.5 0 3.5 3.3 12/31/2005 01:30:00 10 1 12.2 7.2 10.2 1 12.6 7.2 9.4 1.2 12.6 6.1 104 5 109 165 3.4 0 3.5 3.3 12/31/2005 01:40:00 10.8 2 14.9 6.5 11.1 2 15.3 6.1 10.1 2.1 14.1 5.3 95 8 98 165 3.8 0.2 4.3 3.5 12/31/2005 01:50:00 12.1 1.5 15.6 8 12.3 1.5 15.6 8.4 11.3 1.5 15.3 7.2 96 7 89 165 4.1 0 4.3 4 12/31/2005 02:00:00 12.6 1.2 15.6 7.2 12.8 1.3 15.6 8.4 11.7 1.3 14.5 8 100 6 96 165 4.1 0 4.3 4 12/31/2005 02:10:00 12.4 1.3 15.6 8 12.7 1.4 16.4 8 11.6 1.6 15.6 7.6 100 7 112 165 4.1 0 4.3 4 12/31/2005 02:20:00 13 1.1 15.3 8.4 13.3 1.1 15.6 8.8 12.4 1.3 14.9 8.4 109 5 109 165 3.9 0 4.3 3.5 12/31/2005 02:30:00 11.7 1.3 14.9 8.4 11.9 1.3 15.3 8 11 1.5 14.9 7.2 112 7 104 165 4 0 4.3 3.8 12/31/2005 02:40:00 11.3 1.5 14.5 7.2 11.6 1.5 14.5 6.8 10.7 1.5 13.7 6.8 116 6 111 165 4 0 4.3 3.8 12/31/2005 02:50:00 12 1.5 15.6 8 12.3 1.5 15.6 8.4 11.3 1.6 15.3 7.2 106 7 111 165 4 0 4.3 3.8 12/31/2005 03:00:00 11.5 1.2 14.5 8 11.8 1.2 15.3 8.4 10.9 1.3 14.1 8 106 7 105 165 3.9 0 4 3.8 12/31/2005 03:10:00 12.3 1.4 15.3 8.8 12.5 1.4 15.6 9.5 11.9 1.4 15.3 8.4 112 9 106 165 3.8 0 4 3.5 12/31/2005 03:20:00 10.5 1.7 14.5 6.1 10.6 1.7 14.9 6.1 9.9 1.7 14.5 6.5 114 8 105 165 3.9 0 4 3.8 12/31/2005 03:30:00 12 1.5 16.1 7.6 12.3 1.5 16.1 8 11.4 1.5 14.9 7.6 114 9 108 165 4 0 4.3 3.8 12/31/2005 03:40:00 12.7 1.8 17.6 7.6 13 1.8 17.6 7.6 12.1 1.7 17.6 7.2 115 6 110 165 3.6 0.2 4 3.5 12/31/2005 03:50:00 13 1.2 16.4 9.9 13.2 1.2 16.8 9.5 12.5 1.2 15.6 7.6 117 6 116 165 3.6 0 3.8 3.5 12/31/2005 04:00:00 12.4 1.2 15.3 9.1 12.6 1.2 15.3 9.5 12.1 1.3 14.9 8.8 124 8 134 165 3.8 0 3.8 3.5 12/31/2005 04:10:00 12.4 1.3 16.1 9.5 12.6 1.3 16.8 9.5 12 1.3 15.6 8.8 123 6 116 165 3.6 0 3.8 3.5 12/31/2005 04:20:00 12 1 14.9 9.5 12.3 1 15.3 9.9 11.8 1 15.3 9.5 124 6 117 165 3.6 0 3.8 3.5 12/31/2005 04:30:00 12.6 1.7 17.2 8.4 12.8 1.7 17.6 8.8 12.4 1.7 17.2 8.8 123 6 126 165 3.5 0 3.8 3.5 12/31/2005 04:40:00 11.8 1.5 15.3 7.6 12.1 1.5 16.1 8 11.4 1.6 15.6 6.8 118 8 110 165 3.3 0 3.5 3.3 12/31/2005 04:50:00 12.2 1.2 15.6 8.4 12.5 1.3 16.1 8.8 11.4 1.4 14.9 6.1 114 6 111 165 3.2 0 3.3 3.3 12/31/2005 05:00:00 11.8 1.1 16.1 8 12 1.1 16.1 8.8 11.2 1.3 15.6 7.6 113 6 107 165 3.2 0 3.5 3.3 12/31/2005 05:10:00 10.3 1 12.6 8 10.5 1 13.3 8 9.7 1.1 12.2 6.1 116 5 121 165 3.3 0 3.5 3.3 12/31/2005 05:20:00 10.3 1.5 14.9 6.5 10.5 1.5 15.6 6.8 9.8 1.4 13.7 6.5 114 8 119 165 3.3 0 3.5 3.3 12/31/2005 05:30:00 12.6 1.6 16.4 8.4 12.8 1.7 16.8 8.4 12 1.8 15.6 7.2 114 8 118 165 3.2 0 3.5 3 12/31/2005 05:40:00 10.5 1.4 16.1 6.5 10.7 1.5 16.1 6.5 9.9 1.5 16.1 6.8 118 7 119 165 3.2 0 3.3 3 12/31/2005 05:50:00 10.4 0.9 12.6 7.2 10.6 0.9 12.6 6.8 9.5 1 11.8 6.1 108 7 111 165 3.3 0 3.3 3.3 12/31/2005 06:00:00 10.5 0.9 13 8.4 10.8 1 13 7.6 9.8 1 12.6 6.5 104 5 105 165 3.3 0 3.5 3.3 12/31/2005 06:10:00 11 1.3 14.9 8 11.2 1.3 15.3 7.6 10.2 1.5 15.3 6.5 108 6 118 165 3.3 0 3.5 3.3 12/31/2005 06:20:00 13.1 1.3 16.1 9.1 13.3 1.3 16.4 8.8 12.3 1.5 16.1 7.6 109 6 91 165 3 0.1 3.5 2.8 12/31/2005 06:30:00 11.9 1.4 15.3 8 12.2 1.4 15.6 8.4 11.3 1.5 14.9 7.6 108 5 99 165 3.1 0 3.3 3 12/31/2005 06:40:00 10.1 1.2 13.7 6.8 10.3 1.3 14.1 6.5 9.5 1.3 13.3 6.1 103 7 99 165 3.1 0 3.3 3 12/31/2005 06:50:00 11.8 1 14.9 8.8 12 1 15.3 9.1 11.3 1.2 14.1 7.6 107 5 110 165 3 0 3.3 2.8 12/31/2005 07:00:00 10 1.2 12.6 7.6 10.2 1.2 13 7.6 9.6 1.3 13.3 6.8 107 6 105 165 3.2 0 3.3 3 12/31/2005 07:10:00 8.8 0.9 11.5 5.7 9 0.9 11.5 6.1 8.3 1 10.7 6.1 105 6 110 165 3.3 0 3.3 3.3 12/31/2005 07:20:00 8.3 1.2 11.8 5.7 8.5 1.2 12.2 6.1 7.8 1.2 11.1 4.2 99 9 94 165 3.4 0 3.5 3.3 12/31/2005 07:30:00 10.1 1.1 13.7 7.6 10.4 1.1 14.1 8 9.5 1.1 13.3 7.2 90 8 92 165 3.4 0 3.5 3.3 12/31/2005 07:40:00 11.2 1 13.3 7.2 11.5 1.1 13.3 6.8 10.5 1.3 13 6.5 98 5 99 165 3.2 0 3.3 3 12/31/2005 07:50:00 10.8 1.2 14.5 7.2 11 1.3 14.9 7.6 10.2 1.4 14.1 5.7 98 6 99 165 3.3 0 3.5 3.3 12/31/2005 08:00:00 10.2 1.2 13.7 6.8 10.4 1.2 13.7 6.8 9.4 1.2 12.2 5.3 99 7 105 165 3.4 0 3.5 3.3 12/31/2005 08:10:00 10.5 1.2 13.3 6.8 10.7 1.3 13.7 6.5 9.8 1.5 13 6.1 102 7 95 165 3.5 0 3.5 3.3 12/31/2005 08:20:00 9.8 1 11.8 6.5 10.1 1.1 12.6 5.7 9.3 1.1 11.8 5.3 98 9 88 165 3.5 0 3.5 3.3 12/31/2005 08:30:00 10.8 1.1 13.3 7.6 11 1.2 13.3 7.6 10.1 1.3 13.3 6.5 92 7 91 165 3.3 0 3.5 3.3 12/31/2005 08:40:00 11 1.2 14.1 7.6 11.2 1.2 14.5 7.6 10.3 1.4 14.5 7.2 94 7 99 165 3.4 0 3.5 3.3 12/31/2005 08:50:00 10.8 1.2 13.7 7.2 11 1.3 14.1 7.2 10.2 1.2 13 6.5 98 7 105 165 3.3 0 3.5 3.3 12/31/2005 09:00:00 11.1 1.3 15.3 7.6 11.4 1.3 15.6 8 10.6 1.4 14.1 6.8 92 8 98 165 3.3 0 3.5 3.3 12/31/2005 09:10:00 12.4 1.3 16.1 8.4 12.7 1.4 16.1 8.8 11.8 1.5 15.6 7.6 95 9 105 165 3.4 0 3.5 3.3 12/31/2005 09:20:00 10.1 1.8 15.3 6.5 10.3 1.8 16.1 6.5 9.6 1.8 15.3 6.5 107 7 106 165 3.4 0 3.5 3.3 12/31/2005 09:30:00 10.9 1.3 14.5 6.8 11.1 1.3 14.9 6.8 10.3 1.4 14.5 6.8 95 10 105 165 3.3 0 3.5 3.3 12/31/2005 09:40:00 10.6 1.3 14.1 6.5 10.9 1.3 14.1 6.8 10.2 1.4 13.3 6.8 93 8 96 165 3.3 0 3.5 3.3 12/31/2005 09:50:00 10.4 1.1 13.3 7.6 10.7 1.1 13.7 7.6 9.9 1.1 13 7.2 92 7 96 165 3.4 0 3.5 3.3 12/31/2005 10:00:00 10.4 1.1 13.3 7.2 10.6 1.1 13.7 7.2 9.9 1.1 13 7.2 91 7 80 165 3.5 0 3.5 3.3 12/31/2005 10:10:00 9.8 1 11.8 6.5 10 1 12.2 6.8 9.1 1 11.8 6.1 99 7 93 165 3.4 0 3.5 3.3 12/31/2005 10:20:00 8.5 1.5 12.2 4.9 8.7 1.5 12.2 5.3 8.1 1.3 11.8 4.9 95 7 102 165 3.4 0 3.5 3.3 12/31/2005 10:30:00 8 1.1 10.7 5.3 8.2 1.1 11.1 5.3 7.8 1.1 10.7 5.3 82 9 80 165 3.5 0 3.5 3.3 12/31/2005 10:40:00 7.7 1.1 10.7 4.6 7.9 1.1 10.7 4.9 7.6 1.1 10.7 4.9 75 9 71 165 3.4 0 3.5 3.3 12/31/2005 10:50:00 8.8 1.8 12.6 4.9 9.1 1.8 13 5.3 8.6 1.8 13 4.9 84 8 90 165 3.2 0 3.5 3 12/31/2005 11:00:00 10.1 1.1 12.6 6.8 10.3 1.2 13 7.2 9.6 1.2 12.2 6.8 87 7 87 165 3.3 0 3.5 3.3 12/31/2005 11:10:00 9.1 1.3 11.5 5.3 9.4 1.3 11.8 5.7 8.7 1.2 11.8 5.7 88 8 84 165 3.3 0 3.5 3.3 12/31/2005 11:20:00 9.6 1.2 12.2 5.7 9.9 1.3 12.6 5.7 9.3 1.3 13 4.9 89 9 91 165 3.5 0 3.5 3.5 12/31/2005 11:30:00 10.9 1.4 14.5 7.2 11.2 1.4 14.1 8 10.4 1.5 13.3 6.1 81 6 90 165 3.4 0 3.5 3.3 12/31/2005 11:40:00 9.4 1.5 13 6.1 9.7 1.5 13.3 6.1 9.1 1.5 13 5.7 74 9 81 165 3.5 0 3.5 3.5 12/31/2005 11:50:00 8.1 1.8 11.8 4.9 8.3 1.8 12.2 5.3 7.8 1.7 11.8 4.6 70 10 62 165 3.5 0 3.5 3.5 12/31/2005 12:00:00 9.5 1.5 13 5.3 9.8 1.5 13.7 5.7 9.2 1.3 13 5.7 81 8 82 165 3.5 0 3.5 3.5 12/31/2005 12:10:00 10.2 1.3 13.7 6.8 10.5 1.4 14.1 6.8 9.6 1.5 12.6 6.1 94 9 102 165 3.5 0 3.8 3.3 12/31/2005 12:20:00 10.8 1.2 13.7 8 11 1.2 14.1 7.6 10.2 1.2 13.3 6.8 95 7 99 165 3.3 0 3.5 3.3 12/31/2005 12:30:00 10.7 1.3 14.1 7.2 11 1.4 14.5 7.2 10.1 1.5 13.7 5.3 90 9 79 165 3.3 0 3.5 3 12/31/2005 12:40:00 9 1.2 12.6 6.1 9.2 1.2 13 6.5 8.7 1.2 13 5.7 78 8 81 165 3.2 0 3.3 3 12/31/2005 12:50:00 8.5 1.6 13 4.9 8.7 1.7 13.7 4.9 8.3 1.7 13.7 4.2 73 8 76 165 3.2 0 3.3 3.3 12/31/2005 13:00:00 9.8 1.2 13.3 6.5 10 1.2 13.3 6.8 9.6 1.2 12.6 6.5 76 9 78 165 3.3 0 3.5 3.3 12/31/2005 13:10:00 9.8 1.1 12.6 6.8 10.1 1.1 13 6.8 9.4 1.2 11.8 6.5 87 7 89 165 3.5 0 3.5 3.3 12/31/2005 13:20:00 9.9 1.1 12.2 6.8 10.1 1.1 12.6 7.2 9.4 1.2 11.8 6.5 92 7 91 165 3.5 0 3.5 3.5 12/31/2005 13:30:00 8.9 1.2 11.1 4.6 9.1 1.2 11.8 4.6 8.5 1.2 11.5 4.2 112 8 107 165 3.3 0 3.5 3 12/31/2005 13:40:00 8.5 1.3 11.1 4.2 8.6 1.3 11.8 4.6 7.9 1.3 11.5 3.8 97 12 87 165 2.9 0 3.3 2.8 12/31/2005 13:50:00 9.3 1.2 11.5 4.6 9.5 1.2 11.8 4.9 8.8 1.3 11.5 4.2 93 7 89 165 2.9 0 3 2.8 12/31/2005 14:00:00 6.8 0.9 8.8 4.6 7 0.9 9.1 4.6 6.3 0.8 8.4 3.8 94 7 102 165 3 0 3.3 3 12/31/2005 14:10:00 7.4 0.8 8.8 4.6 7.7 0.8 9.1 4.6 7.1 0.8 8.4 4.2 104 7 102 165 3 0 3.3 3 12/31/2005 14:20:00 7.9 0.7 10.7 5.3 8.2 0.7 11.1 5.7 7.6 0.8 9.9 5.3 114 4 108 165 3.3 0 3.5 3 12/31/2005 14:30:00 7.3 0.8 9.1 4.9 7.5 0.8 9.9 5.3 7 1 9.1 4.2 115 7 115 165 3.5 0 3.5 3.3 12/31/2005 14:40:00 5.7 0.7 8 3.8 5.9 0.8 8.4 3.8 5.5 0.7 7.6 3.4 114 7 112 165 3.5 0 3.5 3.5 12/31/2005 14:50:00 7.6 0.8 9.1 4.6 7.9 0.8 9.5 5.3 7.4 0.9 9.5 4.6 115 9 106 165 3.5 0 3.5 3.5 12/31/2005 15:00:00 7.1 0.6 8.8 4.9 7.3 0.6 8.8 5.3 6.8 0.8 8.8 4.9 115 5 111 165 3.5 0 3.5 3.5 12/31/2005 15:10:00 6.5 0.4 7.2 4.9 6.8 0.4 7.6 5.3 6.4 0.5 7.6 4.6 106 4 102 165 3.5 0 3.5 3.3 12/31/2005 15:20:00 6.2 0.6 7.6 4.6 6.5 0.6 8 4.2 6 0.7 7.6 3.8 116 17 113 165 3.3 0 3.5 3.3 12/31/2005 15:30:00 7.6 0.8 9.9 5.7 7.8 0.8 9.9 5.7 7.5 0.9 9.9 5.3 123 7 122 165 2.7 0.2 3.3 2.6 12/31/2005 15:40:00 7.4 0.5 8.8 6.1 7.6 0.5 8.8 6.5 7.3 0.6 8.4 5.3 122 5 125 165 2.8 0.1 3 2.6 12/31/2005 15:50:00 7.4 0.5 9.1 5.7 7.7 0.5 9.1 6.1 7.2 0.6 8.4 5.3 120 5 128 165 3.1 0 3.3 3 12/31/2005 16:00:00 7.1 0.6 8.4 5.7 7.3 0.5 8.4 6.1 7.1 0.6 8.4 5.7 122 5 115 165 3 0 3.3 3 12/31/2005 16:10:00 8 1 11.1 5.7 8.2 1 11.1 5.7 7.7 1.1 10.3 4.9 118 6 112 165 3.1 0 3.3 3 12/31/2005 16:20:00 7.2 0.6 9.1 5.3 7.4 0.6 9.1 5.7 7.1 0.7 9.1 4.6 116 5 121 165 3 0 3.3 3 12/31/2005 16:30:00 7.1 0.7 9.1 5.3 7.3 0.7 9.1 5.3 6.9 0.8 8.8 4.2 117 5 121 165 3 0 3.3 3 12/31/2005 16:40:00 7 0.9 8.8 4.2 7.1 0.9 8.8 4.6 6.7 0.9 8.8 4.2 130 12 130 165 3 0 3.3 2.8 12/31/2005 16:50:00 7.1 0.9 9.1 4.6 7.2 0.9 9.1 4.9 6.8 0.9 8.8 4.6 122 5 116 165 2.7 0 3 2.8 12/31/2005 17:00:00 7.5 0.7 9.5 5.3 7.6 0.6 9.5 5.7 7.3 0.6 8.8 5.7 122 4 122 165 2.7 0 2.8 2.6 12/31/2005 17:10:00 8.3 0.9 10.3 6.5 8.4 0.9 10.3 6.5 8.1 0.9 10.3 6.1 122 5 122 165 2.7 0 2.8 2.6 12/31/2005 17:20:00 7.3 0.6 9.1 6.1 7.4 0.6 9.1 6.1 7.1 0.7 9.5 4.9 118 6 118 165 2.4 0.1 2.8 2.3 12/31/2005 17:30:00 8.1 0.7 10.3 6.1 8.3 0.6 9.9 6.1 7.8 0.7 9.5 5.7 117 4 122 165 2.9 0 3 2.8 12/31/2005 17:40:00 8.3 0.7 10.3 6.5 8.5 0.6 10.3 6.8 8.1 0.7 9.9 6.1 116 5 124 165 3.1 0 3.3 3 12/31/2005 17:50:00 9.1 0.8 11.1 5.7 9.2 0.8 11.1 5.7 8.8 0.8 11.5 6.5 114 6 111 165 3 0 3.3 2.8 12/31/2005 18:00:00 8.1 0.8 10.3 6.1 8.2 0.8 10.3 6.5 7.9 0.8 10.3 6.1 114 6 108 165 2.9 0 3 2.8 12/31/2005 18:10:00 7.5 0.6 9.5 5.7 7.7 0.6 9.5 6.1 7.3 0.6 9.5 4.9 118 5 114 165 3 0 3.3 2.8 12/31/2005 18:20:00 8.2 0.7 10.7 6.5 8.4 0.7 11.1 6.8 7.9 0.9 10.7 5.7 116 5 112 165 3.1 0 3.3 3 12/31/2005 18:30:00 9.2 1.1 11.8 6.8 9.3 1.1 11.8 6.8 8.7 1.1 11.1 6.5 118 6 110 165 3 0 3.3 2.8 12/31/2005 18:40:00 8.5 0.6 9.9 6.5 8.7 0.6 10.3 6.5 8.1 0.9 9.9 5.3 119 6 127 165 3 0 3 2.8 12/31/2005 18:50:00 8.3 1 11.1 6.1 8.4 1 11.1 6.1 8.1 1 10.7 6.1 123 5 122 165 2.9 0 3 2.8 12/31/2005 19:00:00 7 0.8 9.1 4.9 7.1 0.8 9.1 4.6 6.9 0.8 9.1 4.6 128 7 128 165 2.9 0 3 2.8 12/31/2005 19:10:00 7.1 1 9.1 4.9 7.3 1 9.5 5.3 7 1 8.8 4.6 122 7 114 165 2.8 0 3 2.6 12/31/2005 19:20:00 7.7 0.8 9.9 5.7 7.9 0.8 9.9 5.3 7.5 0.8 9.9 5.3 121 7 114 165 2.6 0 2.8 2.6 12/31/2005 19:30:00 7.8 0.6 9.1 5.7 8 0.6 9.5 6.1 7.6 0.7 9.5 4.9 113 5 115 165 2.6 0 2.8 2.6 12/31/2005 19:40:00 8 0.7 10.3 6.5 8.2 0.7 10.3 6.1 7.7 0.9 9.9 4.9 110 6 101 165 2.9 0 3 2.8 12/31/2005 19:50:00 9 0.8 11.5 6.8 9.2 0.8 11.8 6.8 8.7 1 11.5 5.7 113 7 121 165 3 0 3.3 2.8 12/31/2005 20:00:00 9.1 0.8 11.5 7.2 9.3 0.8 11.5 7.2 9.1 0.9 11.5 6.8 126 8 124 165 3.1 0 3.3 3 12/31/2005 20:10:00 8 0.9 10.3 5.7 8 0.9 10.7 5.7 7.8 0.9 10.3 5.3 138 8 145 165 3.2 0 3.3 3 12/31/2005 20:20:00 7.6 0.8 10.7 5.7 7.7 0.8 10.3 5.7 7.4 0.8 10.7 5.7 134 6 130 165 3.2 0 3.5 3 12/31/2005 20:30:00 7.1 0.7 9.1 5.3 7.3 0.7 9.1 5.3 6.9 0.7 9.1 4.9 130 6 131 165 3.2 0 3.3 3 12/31/2005 20:40:00 6.9 0.6 8.4 4.9 7.1 0.6 8.8 5.3 6.7 0.7 8.4 4.2 120 7 112 165 3.1 0 3.3 3 12/31/2005 20:50:00 7.5 0.5 8.8 6.1 7.7 0.5 8.8 6.5 7.2 0.6 9.1 5.3 120 5 112 165 3 0 3.3 3 12/31/2005 21:00:00 8.2 1 12.2 6.1 8.4 1 12.2 6.5 7.9 1.1 13.3 5.7 111 4 113 165 3.2 0 3.3 3 12/31/2005 21:10:00 8 1.3 11.1 4.9 8.1 1.3 11.8 5.3 7.8 1.4 13 5.3 123 9 116 165 3.2 0 3.5 3 12/31/2005 21:20:00 7.5 0.8 10.3 5.7 7.5 0.8 10.3 5.7 7.5 0.7 9.5 6.1 136 7 128 165 3.3 0 3.5 3.3 12/31/2005 21:30:00 8.4 1.3 11.1 4.9 8.5 1.4 11.5 4.9 8.2 1.3 10.7 4.9 127 10 123 165 2.9 0.2 3.5 2.6 12/31/2005 21:40:00 7.9 0.8 9.9 6.5 8 0.8 9.9 6.5 7.5 0.8 9.9 5.3 128 6 121 165 2.4 0 2.8 2.3 12/31/2005 21:50:00 8.4 0.8 10.3 6.1 8.5 0.8 10.7 6.1 8.1 0.8 10.7 5.7 122 5 115 165 2.7 0 2.8 2.6 12/31/2005 22:00:00 8.6 0.8 10.7 5.3 8.8 0.8 11.1 6.1 8.4 0.9 10.3 5.3 116 7 116 165 2.7 0.2 2.8 2.3 12/31/2005 22:10:00 9 0.7 11.1 7.2 9.2 0.6 11.1 7.6 9 0.7 10.7 6.1 127 5 131 165 2.5 0 2.8 2.3 12/31/2005 22:20:00 8.8 0.7 10.7 7.2 9 0.7 10.7 7.6 9 0.6 10.7 7.2 127 5 131 165 2.9 0 3 2.8 12/31/2005 22:30:00 8.8 0.6 10.7 6.8 9 0.6 10.3 6.8 8.9 0.5 10.3 7.6 129 5 126 165 3 0 3 2.8 12/31/2005 22:40:00 8.4 0.7 9.9 6.1 8.5 0.7 10.3 6.1 8.5 0.7 9.9 6.5 132 5 128 165 3 0 3.3 3 12/31/2005 22:50:00 8.7 1 12.2 6.5 8.8 1 11.8 6.5 8.7 1 11.5 6.5 130 8 131 165 3.1 0 3.3 3 12/31/2005 23:00:00 8 1.2 12.2 5.7 8 1.2 12.2 5.7 7.9 1.2 11.8 5.3 138 9 139 165 2.9 0 3.3 2.8 12/31/2005 23:10:00 8 0.8 9.9 6.5 8 0.7 9.9 6.1 7.9 0.9 10.3 5.7 140 8 139 165 2.9 0 3 2.8 12/31/2005 23:20:00 7.7 0.9 10.3 5.7 7.8 0.9 9.9 5.7 7.5 0.9 9.9 5.3 132 6 137 165 2.9 0 3 2.8 12/31/2005 23:30:00 7.1 0.6 8.4 5.7 7.1 0.5 8.8 5.7 7 0.5 8.8 5.7 131 6 138 165 2.9 0 3 2.8 12/31/2005 23:40:00 7.6 0.8 10.7 5.3 7.8 0.8 10.3 5.7 7.7 0.8 10.3 5.7 127 7 135 165 2.9 0 3 2.8 12/31/2005 23:50:00 9.5 1.1 12.2 6.8 9.6 1.1 12.2 6.5 9.4 1.3 12.2 6.1 132 12 124 165 3 0 3.3 3 01/01/2006 00:00:00 9 0.7 11.5 7.2 9 0.7 11.5 7.2 8.8 0.9 11.1 6.8 146 4 147 165 3 0 3.3 2.8 01/01/2006 00:10:00 8.5 0.7 10.7 6.8 8.5 0.7 10.7 6.8 8.4 0.7 10.3 6.5 140 6 138 165 3 0 3.3 2.8 01/01/2006 00:20:00 7 0.7 8.8 5.3 7 0.7 8.8 4.9 6.8 0.8 8.8 4.9 143 7 152 165 3.1 0 3.3 3 01/01/2006 00:30:00 7.2 0.8 9.5 4.9 7.2 0.8 9.5 4.9 6.9 0.8 9.1 4.9 142 8 147 165 3.2 0 3.3 3 01/01/2006 00:40:00 8.2 0.8 9.9 5.3 8.3 0.7 10.3 5.7 7.9 0.7 9.9 6.1 135 7 136 165 3.1 0 3.5 3 01/01/2006 00:50:00 7.9 0.8 10.3 6.1 7.9 0.8 9.9 6.1 7.8 1 10.7 4.9 137 8 141 165 3 0 3.3 3 01/01/2006 01:00:00 7 0.8 9.1 4.9 7.1 0.8 9.1 5.3 6.9 0.9 9.1 4.6 135 6 138 165 3.1 0 3.3 3 01/01/2006 01:10:00 7 0.6 8.4 5.7 7 0.5 8.4 5.7 6.8 0.5 8 4.9 132 5 128 165 3.2 0 3.3 3 01/01/2006 01:20:00 8.6 1.7 13 5.7 8.7 1.7 13 5.7 8.4 1.7 13 5.3 128 15 147 165 3.3 0 3.5 2.8 01/01/2006 01:30:00 9.6 1 11.8 6.8 9.5 0.9 11.8 6.8 9.5 1 12.2 7.2 154 6 153 165 2.6 0.1 3 2.6 01/01/2006 01:40:00 7.6 0.9 9.5 6.1 7.6 0.9 9.5 5.7 7.4 1 9.5 5.7 150 3 151 165 2.6 0 2.8 2.6 01/01/2006 01:50:00 6.5 0.8 8.8 4.9 6.4 0.8 8.4 4.9 6.2 0.8 8.4 4.6 149 4 147 165 2.9 0 3 2.8 01/01/2006 02:00:00 5.4 0.4 6.5 4.2 5.4 0.4 6.8 4.2 5.3 0.5 6.5 3.8 145 6 148 165 3 0 3 2.8 01/01/2006 02:10:00 5.5 0.6 7.2 4.2 5.6 0.6 7.2 4.2 5.4 0.6 6.8 3.8 135 7 133 165 3 0 3.3 2.8 01/01/2006 02:20:00 6.5 0.7 8.4 4.9 6.7 0.7 8.8 4.6 6.4 0.7 8 4.2 131 5 128 165 3 0 3.3 2.8 01/01/2006 02:30:00 6.5 0.5 8.4 5.3 6.7 0.5 8.8 5.7 6.4 0.5 7.6 4.9 130 6 118 165 3.2 0 3.3 3 01/01/2006 02:40:00 6.7 0.6 8.4 4.9 6.9 0.6 8.4 4.9 6.6 0.6 8.8 4.9 129 6 125 165 3.2 0 3.3 3 01/01/2006 02:50:00 7.4 0.6 8.8 6.1 7.5 0.6 9.1 6.1 7.4 0.6 8.8 6.1 127 6 126 165 3.3 0 3.5 3.3 01/01/2006 03:00:00 7.8 0.6 9.1 6.1 7.9 0.5 9.5 6.5 7.7 0.5 8.8 5.7 126 4 119 165 3.3 0 3.5 3.3 01/01/2006 03:10:00 8.1 0.5 9.1 6.5 8.2 0.5 9.5 6.5 8 0.6 9.5 5.7 126 6 123 165 3.3 0 3.5 3.3 01/01/2006 03:20:00 7.9 0.9 10.3 5.7 7.9 0.9 10.3 5.7 7.6 0.8 9.9 5.7 127 7 128 165 3.4 0 3.5 3.3 01/01/2006 03:30:00 7.8 0.6 9.5 6.1 7.9 0.6 9.5 5.7 7.7 0.6 9.1 6.1 126 5 124 165 3.4 0 3.5 3.3 01/01/2006 03:40:00 7.7 0.6 9.1 5.7 7.8 0.6 9.1 5.7 7.5 0.5 9.1 6.1 123 5 121 165 3.4 0 3.5 3.3 01/01/2006 03:50:00 9.3 1 11.8 7.2 9.4 1 12.2 7.2 9.2 1 11.8 5.7 126 6 129 165 3.4 0 3.5 3.3 01/01/2006 04:00:00 8.3 0.8 11.1 6.1 8.4 0.8 11.1 6.1 8.2 0.9 10.7 6.1 128 7 126 165 3.3 0 3.5 3.3 01/01/2006 04:10:00 9.1 0.9 11.8 6.8 9.2 0.9 11.8 7.2 8.9 1.1 11.5 5.7 123 9 125 165 3.3 0 3.5 3.3 01/01/2006 04:20:00 8.2 1 11.5 5.7 8.3 1 11.8 5.7 8.1 0.9 11.1 6.1 129 8 115 165 3.3 0 3.5 3.3 01/01/2006 04:30:00 7.9 0.8 10.3 5.3 7.9 0.7 10.3 6.1 7.9 0.7 9.5 5.7 131 7 128 165 3.4 0 3.5 3.3 01/01/2006 04:40:00 7.5 0.7 9.5 5.3 7.6 0.8 9.9 5.3 7.4 0.8 9.1 5.3 125 8 126 165 3.4 0 3.5 3.3 01/01/2006 04:50:00 7.7 0.7 9.5 6.1 7.8 0.7 9.5 6.1 7.7 0.8 9.1 5.3 125 6 128 165 3.3 0 3.5 3.3 01/01/2006 05:00:00 8.2 0.6 9.9 6.5 8.3 0.6 9.9 6.1 8 0.7 9.9 6.1 120 6 122 165 3.2 0 3.5 3.3 01/01/2006 05:10:00 10.2 1.1 13 7.2 10.3 1.1 13.3 7.2 10 1.2 13 6.5 122 7 116 165 3.2 0 3.3 3 01/01/2006 05:20:00 8.5 0.7 10.3 6.5 8.7 0.7 10.7 6.5 8.4 0.8 10.7 5.7 126 8 126 165 3 0 3.3 2.8 01/01/2006 05:30:00 7.3 0.7 9.1 5.3 7.4 0.7 9.1 5.3 7.2 0.8 9.9 4.6 131 5 133 165 2.9 0 3.3 2.8 01/01/2006 05:40:00 6.6 1.2 10.3 4.2 6.8 1.3 10.7 4.2 6.3 1.2 9.5 3.8 112 13 87 165 2.9 0.2 3 2.3 01/01/2006 05:50:00 8.3 0.9 10.7 6.1 8.5 0.9 11.5 6.1 7.9 1 10.3 5.3 117 7 123 165 2.3 0 2.6 2.1 01/01/2006 06:00:00 8.4 0.5 9.9 6.5 8.5 0.5 9.9 6.8 8.3 0.6 9.9 5.7 125 4 128 165 2.3 0.2 2.6 2.1 01/01/2006 06:10:00 8 0.5 9.9 6.5 8.1 0.5 9.9 6.5 7.6 0.6 9.1 5.3 117 6 107 165 2.6 0 2.8 2.6 01/01/2006 06:20:00 7.8 0.7 9.9 5.7 7.9 0.7 9.9 6.1 7.5 0.8 9.5 5.7 115 7 121 165 2.6 0 2.8 2.6 01/01/2006 06:30:00 7.8 0.7 9.5 5.7 8 0.8 9.9 5.7 7.4 1 9.9 4.2 108 7 101 165 2.7 0 2.8 2.6 01/01/2006 06:40:00 9.1 1.2 11.8 5.3 9.3 1.2 12.2 5.3 8.6 1.3 11.5 4.2 110 5 106 165 2.6 0 2.8 2.6 01/01/2006 06:50:00 9.2 0.9 11.5 6.5 9.4 0.9 11.8 6.5 8.8 1 11.8 6.1 117 5 117 165 2.4 0 2.6 2.3 01/01/2006 07:00:00 8.1 0.6 9.5 6.5 8.3 0.6 9.5 6.8 7.9 0.8 9.9 5.3 116 5 116 165 2.4 0 2.6 2.3 01/01/2006 07:10:00 8.8 1.1 11.5 6.1 9 1.1 11.8 6.5 8.5 1.1 11.8 5.7 117 7 112 165 2.4 0 2.6 2.3 01/01/2006 07:20:00 7.5 0.6 9.5 5.3 7.6 0.6 9.9 5.3 7.2 0.7 8.8 4.9 115 6 111 165 2.1 0 2.6 2.1 01/01/2006 07:30:00 8.7 0.6 9.9 7.2 8.9 0.5 10.3 7.2 8.3 0.7 9.9 5.7 112 4 111 165 2.4 0.1 2.6 2.3 01/01/2006 07:40:00 9.6 0.8 12.2 7.2 9.7 0.8 12.2 7.2 9.2 1.1 11.8 5.3 113 6 124 165 2.6 0 2.8 2.6 01/01/2006 07:50:00 8.4 1 10.7 6.1 8.5 1 10.7 6.5 8 1.1 11.5 5.7 114 7 111 165 2.9 0 3 2.8 01/01/2006 08:00:00 9.1 1.3 13.3 6.5 9.3 1.3 13.3 6.5 8.8 1.3 12.2 6.1 127 8 124 165 2.8 0 3 2.8 01/01/2006 08:10:00 8.7 0.9 10.7 6.1 8.9 0.9 11.1 5.7 8.4 1 11.1 5.7 127 7 116 165 2.7 0 3 2.8 01/01/2006 08:20:00 8.7 0.9 10.7 6.8 8.9 0.9 11.1 6.5 8.6 0.9 11.1 6.5 127 5 120 165 2.8 0 2.8 2.8 01/01/2006 08:30:00 8.7 0.9 11.1 5.3 8.8 0.9 11.1 5.3 8.7 1 11.5 5.7 130 8 124 165 2.8 0 2.8 2.8 01/01/2006 08:40:00 8.9 0.8 11.5 6.8 9 0.8 11.5 6.5 8.7 1 11.8 5.7 131 7 130 165 2.7 0 2.8 2.8 01/01/2006 08:50:00 8.9 0.8 11.5 7.2 9 0.8 11.5 7.2 8.8 0.9 11.5 6.8 129 6 116 165 2.7 0 2.8 2.6 01/01/2006 09:00:00 8.9 1 11.8 5.7 9 1 11.8 6.5 8.8 1 11.1 6.1 127 9 128 165 2.7 0 2.8 2.6 01/01/2006 09:10:00 8.8 1 11.5 6.5 8.9 1 11.5 6.5 8.6 1 11.5 6.1 129 8 135 165 2.6 0 2.8 2.6 01/01/2006 09:20:00 8.6 0.8 10.7 6.5 8.8 0.8 10.7 6.5 8.3 1 10.7 6.1 121 6 121 165 2.7 0 2.8 2.6 01/01/2006 09:30:00 8.9 0.7 11.1 7.2 9 0.7 11.1 6.8 8.6 0.8 10.3 6.1 121 5 121 165 2.7 0 2.8 2.6 01/01/2006 09:40:00 8.9 0.6 10.7 7.2 9.1 0.6 10.7 7.6 8.6 0.6 9.9 6.8 119 4 122 165 2.6 0 2.8 2.6 01/01/2006 09:50:00 9.2 1.3 13 6.1 9.4 1.3 13.3 6.1 9 1.4 13 5.7 121 6 121 165 2.5 0 2.8 2.6 01/01/2006 10:00:00 8.7 0.6 10.7 7.2 8.8 0.6 10.7 7.2 8.4 0.7 9.9 6.5 120 5 119 165 2.5 0 2.8 2.6 01/01/2006 10:10:00 8.9 0.9 11.8 6.1 9.1 0.9 11.5 6.5 8.6 1 11.8 5.7 115 6 133 165 2.7 0 2.8 2.6 01/01/2006 10:20:00 8.6 0.9 11.1 6.8 8.7 0.9 11.5 6.5 8.4 1 12.2 6.1 126 7 123 165 2.7 0 2.8 2.6 01/01/2006 10:30:00 9.1 1 12.2 6.8 9.2 1 12.2 6.8 9 1 11.8 6.8 126 7 128 165 2.7 0 2.8 2.8 01/01/2006 10:40:00 8.5 0.8 10.3 6.1 8.7 0.8 10.7 5.7 8.1 0.9 10.3 5.3 116 5 119 165 2.7 0 2.8 2.6 01/01/2006 10:50:00 7.6 0.7 9.5 6.1 7.7 0.8 9.9 6.1 7.3 0.8 9.1 4.6 117 5 104 165 2.7 0 2.8 2.6 01/01/2006 11:00:00 8.8 1.1 11.5 6.5 8.9 1.1 11.5 6.5 8.4 1.3 12.2 5.3 123 8 126 165 2.4 0.2 2.8 2.1 01/01/2006 11:10:00 7.2 0.9 9.5 4.2 7.3 1 9.1 4.2 7.1 0.9 9.5 4.9 127 7 132 165 2.2 0 2.3 1.8 01/01/2006 11:20:00 8.1 0.6 9.5 6.5 8.3 0.6 9.9 6.8 7.7 0.7 9.5 5.3 114 6 111 165 2.4 0.1 2.8 2.3 01/01/2006 11:30:00 9 0.6 10.7 7.6 9.2 0.6 11.5 7.6 8.7 0.7 10.7 6.8 111 4 114 165 2.7 0 2.8 2.6 01/01/2006 11:40:00 7.8 0.7 9.9 6.5 8.1 0.7 10.3 6.5 7.3 0.9 9.9 4.9 104 6 97 165 2.8 0 3 2.8 01/01/2006 11:50:00 9.2 0.8 11.8 6.8 9.5 0.8 11.8 7.2 9 0.8 11.5 6.1 113 6 106 165 2.9 0 3 2.8 01/01/2006 12:00:00 8.4 0.6 10.3 6.1 8.6 0.7 10.7 6.1 8.1 0.8 9.9 5.7 120 5 130 165 2.9 0 3 2.8 01/01/2006 12:10:00 9 1.2 11.8 6.8 9.1 1.1 12.2 6.8 8.6 1.1 11.5 6.1 118 5 121 165 2.8 0 3 2.6 01/01/2006 12:20:00 8.4 0.7 10.3 5.7 8.6 0.6 10.7 6.5 7.9 0.8 9.5 5.7 105 5 114 165 2.7 0 2.8 2.6 01/01/2006 12:30:00 9.2 1 11.8 7.2 9.4 0.9 12.6 7.6 8.7 1 12.2 6.5 109 5 110 165 2.7 0 2.8 2.6 01/01/2006 12:40:00 8.9 0.7 11.1 7.2 9 0.7 11.5 7.2 8.6 0.8 10.3 6.5 111 4 112 165 2.7 0 2.8 2.6 01/01/2006 12:50:00 8.6 0.5 10.3 7.2 8.8 0.6 10.7 7.2 8.2 0.6 9.5 6.5 108 5 102 165 2.7 0 2.8 2.6 01/01/2006 13:00:00 8.9 0.7 10.7 6.5 9.1 0.8 11.1 6.1 8.3 1 10.3 4.6 102 5 101 165 2.9 0 3 2.8 01/01/2006 13:10:00 9.3 0.9 11.5 5.3 9.5 0.9 11.8 5.3 8.8 1 10.7 5.3 106 6 108 165 2.9 0 3.3 2.8 01/01/2006 13:20:00 9.2 1.1 11.8 6.5 9.3 1.2 12.2 6.5 8.7 1.3 11.5 4.9 112 6 110 165 2.9 0 3 2.8 01/01/2006 13:30:00 8.2 0.9 10.3 4.6 8.3 0.9 10.3 5.3 7.9 1 9.9 5.3 117 5 120 165 2.9 0 3 2.8 01/01/2006 13:40:00 7.8 0.7 9.5 5.3 8 0.7 9.5 5.3 7.4 0.8 9.1 4.9 111 8 108 165 2.9 0 3 2.8 01/01/2006 13:50:00 8.2 0.7 9.9 6.5 8.4 0.7 10.3 6.8 7.8 0.7 9.5 5.7 107 6 112 165 3 0 3 2.8 01/01/2006 14:00:00 9.1 1.1 11.8 6.1 9.2 1.1 12.2 6.1 8.5 1.3 12.6 4.9 112 6 106 165 2.9 0 3.3 2.8 01/01/2006 14:10:00 9.3 0.8 11.5 7.2 9.5 0.8 11.8 7.6 8.9 0.9 11.1 6.5 115 7 121 165 2.5 0.1 2.8 2.6 01/01/2006 14:20:00 7.6 1 10.7 5.3 7.7 1 11.1 4.9 7.1 1 9.9 4.2 118 6 121 165 2.5 0 2.6 2.3 01/01/2006 14:30:00 9.1 1.7 13 6.1 9.3 1.7 13 6.5 8.6 1.7 12.6 5.7 120 7 114 165 2.5 0.1 2.8 2.3 01/01/2006 14:40:00 8.3 1.1 10.3 4.9 8.5 1.2 10.3 5.3 7.7 1.1 9.9 4.9 111 7 104 165 2.6 0 2.8 2.3 01/01/2006 14:50:00 9.2 0.7 11.1 6.8 9.4 0.7 11.5 7.2 8.9 0.9 11.5 5.3 109 4 106 165 2.9 0 3 2.8 01/01/2006 15:00:00 8.5 1.3 11.8 4.9 8.7 1.3 11.5 4.9 8 1.5 11.1 4.6 105 7 102 165 2.9 0 3 2.8 01/01/2006 15:10:00 8.2 0.9 10.7 6.1 8.4 0.9 10.7 6.1 7.6 1 9.9 5.3 97 6 102 165 3 0 3 2.8 01/01/2006 15:20:00 9.5 0.8 11.5 6.1 9.7 0.8 11.5 6.5 9 1 11.1 6.1 105 5 106 165 3 0 3 2.8 01/01/2006 15:30:00 9.1 0.9 11.1 5.7 9.3 0.9 11.1 6.1 8.5 1 11.1 5.3 103 6 104 165 2.9 0 3 2.8 01/01/2006 15:40:00 9.6 0.9 11.5 7.2 9.8 1 11.8 6.5 9 1 11.5 6.1 102 6 95 165 3 0 3 2.8 01/01/2006 15:50:00 8.6 1 11.1 4.9 8.8 1 11.5 4.9 8.1 1 11.1 5.3 101 6 99 165 2.9 0 3 2.8 01/01/2006 16:00:00 10 1 12.2 6.5 10.2 1 12.2 6.8 9.3 1.2 12.2 5.3 103 5 103 165 3 0 3.3 2.8 01/01/2006 16:10:00 10.1 1 11.8 6.5 10.3 1 12.2 6.8 9.5 1.1 11.8 6.5 105 5 102 165 2.9 0 3 2.8 01/01/2006 16:20:00 10.2 1.1 13 6.1 10.4 1.1 13 6.8 9.5 1.1 12.2 6.8 106 6 102 165 2.9 0 3 2.8 01/01/2006 16:30:00 9.7 1.6 13.3 6.5 9.8 1.6 13.7 6.5 9.2 1.7 13.3 5.3 116 8 102 165 2.7 0 3 2.6 01/01/2006 16:40:00 7.3 1 10.7 4.6 7.5 1 10.7 4.6 6.8 1.1 10.7 4.2 109 7 112 165 2.7 0 2.8 2.6 01/01/2006 16:50:00 10.1 1.3 13 5.7 10.3 1.3 13.3 6.1 9.4 1.4 13.3 5.7 101 6 100 165 2.9 0 3.3 2.8 01/01/2006 17:00:00 10.2 1 13.3 8 10.5 1 13.7 8.4 10 1.1 12.6 6.8 119 9 112 165 3 0 3.3 2.8 01/01/2006 17:10:00 10.4 1 12.6 7.6 10.6 1 13 7.6 10.1 1.1 13 7.2 119 6 126 165 2.8 0 3 2.6 01/01/2006 17:20:00 9.5 1 12.6 6.8 9.7 1 13.3 6.8 9.1 1 11.8 6.8 118 6 108 165 2.7 0 2.8 2.6 01/01/2006 17:30:00 9.2 1 12.2 6.8 9.4 1 12.2 6.8 8.8 1.1 12.2 6.1 116 7 115 165 2.9 0 3 2.8 01/01/2006 17:40:00 10.2 0.8 12.2 8.4 10.5 0.8 12.2 8 9.8 0.9 12.2 7.6 112 5 107 165 2.9 0 3 2.8 01/01/2006 17:50:00 9.3 0.6 11.1 7.6 9.5 0.7 11.5 8 8.7 1 12.6 6.1 112 5 115 165 3 0 3.3 2.8 01/01/2006 18:00:00 11.4 1.3 14.5 7.6 11.7 1.3 15.3 7.2 11.1 1.5 14.5 6.5 121 6 112 165 2.2 0.3 3.3 1.8 01/01/2006 18:10:00 11.2 1.1 13.3 8 11.3 1.1 13.7 8 10.5 1.3 13.3 7.2 115 5 109 165 2.4 0.1 2.6 2.1 01/01/2006 18:20:00 9.8 0.9 11.5 7.2 10 0.9 11.8 7.2 9.2 1 11.5 6.5 108 5 111 165 2.7 0 2.8 2.6 01/01/2006 18:30:00 9.2 1 11.8 6.8 9.4 1 12.2 6.8 8.8 1.1 11.8 6.1 113 6 100 165 2.7 0 2.8 2.6 01/01/2006 18:40:00 8.5 0.9 10.7 5.3 8.7 0.9 10.7 5.7 7.9 1 10.3 4.9 113 6 108 165 2.9 0 3 2.8 01/01/2006 18:50:00 9.9 0.9 11.8 7.2 10.1 0.9 12.2 7.2 9.4 1 12.2 6.8 110 6 98 165 2.9 0 3 2.8 01/01/2006 19:00:00 10.6 1.7 14.9 6.1 10.8 1.7 15.3 6.1 10.1 2.1 14.5 4.6 121 12 131 165 2.6 0.2 3 2.1 01/01/2006 19:10:00 9.4 1.3 12.2 6.8 9.5 1.3 12.6 6.8 9.3 1.2 12.2 6.5 130 5 140 165 2.2 0 2.3 2.1 01/01/2006 19:20:00 7.5 0.8 9.5 5.3 7.6 0.8 9.5 5.3 7.3 0.8 9.1 5.3 126 8 139 165 2.3 0 2.6 2.3 01/01/2006 19:30:00 8.2 0.6 9.9 6.1 8.4 0.6 9.9 6.8 7.8 0.8 9.9 5.3 116 5 114 165 2.4 0 2.8 2.3 01/01/2006 19:40:00 8.5 0.6 11.1 6.5 8.7 0.6 11.5 6.5 8.3 0.7 10.3 5.7 112 5 99 165 2.6 0 2.8 2.6 01/01/2006 19:50:00 10 0.8 11.8 8 10.2 0.8 12.2 7.2 9.5 1 11.5 6.1 114 5 116 165 2.4 0 2.6 2.3 01/01/2006 20:00:00 10.4 1 12.2 8 10.5 1 12.6 8 9.8 1 12.6 7.2 109 5 110 165 2.5 0 2.8 2.3 01/01/2006 20:10:00 8.9 0.6 10.7 6.1 9.1 0.6 10.7 6.5 8.5 0.8 10.3 5.3 107 5 111 165 2.7 0 2.8 2.6 01/01/2006 20:20:00 9.2 0.8 11.1 6.8 9.4 0.8 11.1 6.5 8.5 1 10.7 5.3 103 5 101 165 2.7 0 2.8 2.6 01/01/2006 20:30:00 10.1 1 13 6.8 10.3 1 13.3 6.8 9.8 1.2 13 6.1 111 7 105 165 2.7 0 2.8 2.6 01/01/2006 20:40:00 9.3 1.1 12.6 6.8 9.5 1.1 12.6 6.8 9.2 1 12.2 6.8 122 5 121 165 2.8 0 2.8 2.6 01/01/2006 20:50:00 8.2 0.8 11.1 5.7 8.3 0.8 11.1 6.1 8 0.9 11.1 5.3 118 6 123 165 2.8 0 2.8 2.8 01/01/2006 21:00:00 8.2 0.6 9.5 6.5 8.4 0.6 9.9 6.5 7.9 0.8 9.5 5.7 109 5 122 165 2.8 0 2.8 2.8 01/01/2006 21:10:00 10.1 1.1 13 7.6 10.3 1.1 13 8 9.8 1.3 13.7 6.8 111 9 108 165 2.6 0.2 2.8 2.3 01/01/2006 21:20:00 8.7 1.4 12.6 4.9 8.8 1.4 13 5.3 8.3 1.4 12.6 4.9 125 8 129 165 2.4 0 2.6 2.3 01/01/2006 21:30:00 9 0.7 11.1 6.8 9.2 0.7 11.1 6.8 8.8 0.8 11.1 6.1 119 5 114 165 2.4 0 2.6 2.3 01/01/2006 21:40:00 9.1 0.8 11.5 7.2 9.3 0.8 11.8 7.2 8.8 0.8 10.7 6.1 116 4 121 165 2.4 0 2.6 2.3 01/01/2006 21:50:00 8.9 0.8 10.7 6.5 9.1 0.8 10.7 6.5 8.8 1 11.5 6.1 125 8 118 165 2.2 0 2.6 1.8 01/01/2006 22:00:00 7.6 1.2 10.3 4.9 7.8 1.2 10.7 4.6 7.7 1.4 10.3 4.6 134 8 126 165 2 0 2.3 1.8 01/01/2006 22:10:00 7.9 0.8 10.3 6.1 8 0.8 10.7 5.7 7.9 0.9 10.3 5.3 141 8 124 165 2.3 0.1 2.6 1.8 01/01/2006 22:20:00 6.7 0.5 8 5.3 6.7 0.5 8 5.3 6.7 0.6 8.4 4.9 142 7 151 165 2.6 0 2.8 2.6 01/01/2006 22:30:00 7.5 0.5 8.8 5.7 7.5 0.5 8.8 6.1 7.4 0.5 8.8 5.7 145 5 136 165 2.7 0 2.8 2.6 01/01/2006 22:40:00 6.6 0.7 8.4 4.9 6.6 0.6 8 4.9 6.5 0.7 8 4.6 141 7 143 165 2.6 0 2.8 2.6 01/01/2006 22:50:00 7.2 0.9 9.5 4.6 7.2 0.9 9.5 5.3 7 0.9 9.9 4.9 137 7 136 165 2.7 0 2.8 2.6 01/01/2006 23:00:00 8 0.9 9.9 5.7 8 0.9 9.9 5.7 7.8 0.9 9.9 5.3 136 6 131 165 2.8 0 2.8 2.8 01/01/2006 23:10:00 8 0.7 9.5 5.3 8.1 0.8 9.9 5.3 7.9 0.9 9.5 4.9 131 7 133 165 2.8 0 2.8 2.8 01/01/2006 23:20:00 9.5 0.8 11.5 7.2 9.6 0.9 11.8 7.2 9.3 0.9 11.5 6.5 140 8 126 165 2.8 0 3 2.8 01/01/2006 23:30:00 7.1 0.6 9.1 5.3 7.1 0.6 9.1 5.3 7 0.7 9.1 4.9 142 6 153 165 2.9 0 3 2.8 01/01/2006 23:40:00 5.7 0.6 7.6 4.2 5.8 0.6 7.6 4.2 5.7 0.7 8 3.4 138 8 139 165 2.9 0 3 2.8 01/01/2006 23:50:00 8.3 1.1 10.3 4.2 8.4 1.1 10.7 4.2 8.1 1.4 10.3 3.8 133 9 139 165 2.9 0 3 2.8 01/02/2006 00:00:00 8.5 0.8 10.3 6.5 8.6 0.8 10.7 6.5 8.2 0.8 10.3 6.1 138 6 135 165 2.7 0 2.8 2.6 01/02/2006 00:10:00 8.1 1 10.3 5.3 8.1 1 10.3 4.9 7.8 1 9.9 5.7 139 7 138 165 2.6 0 2.8 2.6 01/02/2006 00:20:00 8.4 0.9 11.1 6.5 8.5 0.9 11.5 6.1 8.3 0.9 11.1 6.1 140 8 128 165 2.6 0 2.8 2.6 01/02/2006 00:30:00 9.8 0.9 12.2 7.2 9.9 0.9 12.2 6.8 9.5 0.9 11.8 6.5 136 5 133 165 2.2 0.1 2.8 2.1 01/02/2006 00:40:00 8.9 0.8 11.1 6.8 9 0.9 11.5 6.1 8.7 1 12.2 5.7 137 8 144 165 2.2 0 2.3 1.8 01/02/2006 00:50:00 7.3 1 9.9 5.3 7.4 0.9 9.9 4.9 7.3 1 9.5 4.6 140 7 148 165 2.4 0 2.6 2.3 01/02/2006 01:00:00 6.8 0.6 8.4 4.9 6.9 0.6 8.8 5.3 6.8 0.6 8.4 4.9 133 7 123 165 2.4 0 2.6 2.3 01/02/2006 01:10:00 6.9 0.8 9.9 4.2 6.9 0.8 9.1 4.2 7 0.8 9.1 4.9 133 9 126 165 2.6 0 2.8 2.6 01/02/2006 01:20:00 8.1 0.8 10.3 6.5 8.2 0.8 10.3 6.8 8 0.8 9.5 6.5 141 6 128 165 2.7 0 2.8 2.6 01/02/2006 01:30:00 7.6 0.6 9.5 5.7 7.6 0.6 9.5 5.7 7.5 0.7 9.5 5.7 147 7 145 165 2.8 0 2.8 2.8 01/02/2006 01:40:00 6.9 0.9 8.8 5.3 6.9 0.9 8.8 5.3 6.8 1 8.8 4.9 149 6 158 165 2.9 0 3 2.8 01/02/2006 01:50:00 7.2 0.6 8.8 5.3 7.2 0.6 8.8 5.7 7.1 0.6 9.1 5.3 155 6 164 165 2.8 0 3 2.6 01/02/2006 02:00:00 7.1 0.6 8.4 5.3 7.1 0.6 8.4 4.9 6.8 0.6 8.4 4.9 145 4 151 165 2.5 0 2.8 2.6 01/02/2006 02:10:00 6.3 0.4 7.2 5.3 6.4 0.4 7.2 5.3 6.2 0.5 7.2 4.9 143 4 146 165 2.5 0 2.6 2.6 01/02/2006 02:20:00 6.4 0.7 8 4.9 6.4 0.7 8 4.9 6.1 0.7 8 4.6 142 5 144 165 2.6 0 2.8 2.6 01/02/2006 02:30:00 8.2 2.1 11.8 4.6 8.2 2 11.8 4.6 8 2.2 12.6 4.2 143 8 151 165 2.7 0 2.8 2.6 01/02/2006 02:40:00 8.4 0.7 9.9 6.5 8.5 0.7 10.3 6.5 8.4 0.7 10.3 6.8 147 3 152 165 2.6 0.1 2.8 2.6 01/02/2006 02:50:00 7 0.5 8 5.3 7 0.5 8 5.3 6.9 0.5 8.4 5.7 147 3 145 165 2.4 0 2.6 2.3 01/02/2006 03:00:00 6.3 0.4 7.2 4.9 6.2 0.4 7.2 5.3 6.2 0.4 7.2 5.3 151 3 150 165 2.4 0 2.6 2.3 01/02/2006 03:10:00 6.5 0.6 8.4 5.3 6.5 0.6 8.4 4.9 6.4 0.6 8.4 4.9 146 5 146 165 2.5 0 2.8 2.6 01/02/2006 03:20:00 7.3 0.9 9.9 5.3 7.3 0.9 9.9 5.3 7.1 0.9 10.3 4.9 138 6 136 165 2.7 0 2.8 2.6 01/02/2006 03:30:00 8.8 0.6 10.3 6.8 8.8 0.6 10.3 6.8 8.7 0.6 10.7 6.8 148 7 128 165 2.9 0 3 2.8 01/02/2006 03:40:00 7.5 0.9 9.5 5.7 7.5 0.9 9.1 5.7 7.5 0.9 9.5 4.9 157 4 162 165 2.9 0 3 2.8 01/02/2006 03:50:00 6.8 0.6 8.8 5.3 6.8 0.6 8.8 5.3 6.8 0.6 8.4 5.3 153 7 159 165 2.7 0 3 2.8 01/02/2006 04:00:00 6.9 0.5 8.4 6.1 6.9 0.5 8.4 6.1 6.8 0.6 8.4 4.9 145 4 144 165 2.7 0 2.8 2.6 01/02/2006 04:10:00 7.5 0.5 8.8 6.5 7.5 0.4 8.8 6.5 7.4 0.5 8.8 5.7 145 5 145 165 2.6 0 2.8 2.6 01/02/2006 04:20:00 7.7 0.5 8.8 6.1 7.8 0.5 9.1 6.5 7.6 0.5 9.1 5.3 144 4 129 165 2.6 0 2.8 2.6 01/02/2006 04:30:00 8.1 0.5 9.1 6.8 8.2 0.4 9.5 6.8 8.1 0.5 9.1 6.5 145 3 147 165 2.5 0 2.6 2.6 01/02/2006 04:40:00 7.8 0.6 9.1 6.5 7.8 0.5 9.1 6.5 7.7 0.5 8.8 6.1 144 4 143 165 2.7 0 2.8 2.6 01/02/2006 04:50:00 7.9 0.6 9.5 6.5 7.9 0.5 9.5 6.5 7.8 0.6 9.1 5.7 145 4 146 165 2.7 0 3 2.6 01/02/2006 05:00:00 7.7 0.4 8.8 6.5 7.7 0.4 8.8 6.5 7.6 0.5 8.8 6.1 153 3 151 165 2.7 0 2.8 2.6 01/02/2006 05:10:00 7.6 0.4 8.4 6.5 7.7 0.4 8.8 6.8 7.7 0.4 8.4 6.5 151 2 146 165 2.7 0 2.8 2.6 01/02/2006 05:20:00 7.2 0.4 7.6 5.7 7.2 0.4 7.6 6.1 7.2 0.5 8 5.3 151 3 145 165 2.6 0 2.8 2.6 01/02/2006 05:30:00 6.4 0.4 7.2 5.3 6.4 0.4 7.2 5.7 6.3 0.4 7.2 5.3 151 3 153 165 2.6 0 2.8 2.6 01/02/2006 05:40:00 5.7 0.3 6.5 4.9 5.7 0.3 6.5 4.9 5.7 0.3 6.5 4.9 148 3 148 165 2.7 0 2.8 2.6 01/02/2006 05:50:00 6.6 0.6 8 4.9 6.6 0.6 8 4.9 6.6 0.6 8.4 4.9 145 6 147 165 2.7 0 2.8 2.6 01/02/2006 06:00:00 6.4 0.6 8 4.9 6.5 0.6 8 5.3 6.3 0.6 8 4.9 151 3 154 165 2.4 0 2.8 2.3 01/02/2006 06:10:00 5.3 0.3 6.1 4.6 5.3 0.3 6.1 4.6 5.4 0.3 6.1 4.6 156 5 147 165 2.4 0 2.6 2.3 01/02/2006 06:20:00 5.1 0.5 6.5 4.2 5.1 0.4 6.1 4.2 5.1 0.5 6.1 3.8 153 4 158 165 2.3 0 2.6 2.3 01/02/2006 06:30:00 5.3 0.5 6.5 3.8 5.2 0.5 6.1 4.2 5.3 0.6 6.5 3.4 153 8 148 165 2.3 0 2.6 2.3 01/02/2006 06:40:00 4.4 0.4 5.7 3.4 4.4 0.4 5.3 3.4 4.5 0.4 5.3 3.4 160 5 161 165 2.2 0 2.3 2.1 01/02/2006 06:50:00 4.1 0.4 4.9 3 4.1 0.3 4.9 3 4.2 0.3 4.9 3.4 158 5 164 165 2.1 0 2.3 2.1 01/02/2006 07:00:00 4.5 0.3 4.9 3.8 4.4 0.3 5.3 3.8 4.5 0.3 4.9 3.8 150 3 154 165 2.2 0 2.3 2.1 01/02/2006 07:10:00 3.9 0.4 4.9 2.6 3.9 0.4 4.9 2.6 3.8 0.5 4.6 1.9 153 6 149 165 2.2 0 2.3 2.1 01/02/2006 07:20:00 3.8 0.5 4.6 3 3.7 0.4 4.6 2.6 3.6 0.5 4.6 2.3 155 7 156 165 2.2 0 2.3 2.1 01/02/2006 07:30:00 4 0.4 5.3 3 4 0.4 4.9 3 4 0.4 5.3 3 153 7 153 165 2.2 0 2.3 2.1 01/02/2006 07:40:00 3.5 0.4 4.9 2.6 3.5 0.4 4.6 2.3 3.5 0.4 4.6 2.3 152 6 151 165 2.1 0 2.3 2.1 01/02/2006 07:50:00 2.8 0.4 3.8 1.9 2.8 0.3 3.8 2.3 2.7 0.4 3.8 1.9 152 7 149 165 2.1 0 2.3 2.1 01/02/2006 08:00:00 3.4 0.4 4.2 2.6 3.4 0.3 4.2 2.6 3.4 0.4 4.2 2.6 145 5 140 165 2.2 0 2.3 2.1 01/02/2006 08:10:00 4.5 0.4 5.3 3.4 4.4 0.4 5.3 3.4 4.6 0.4 5.3 3.8 160 8 155 165 2.1 0 2.3 1.8 01/02/2006 08:20:00 4.3 0.3 4.9 3.4 4.2 0.3 4.9 3.4 4.4 0.3 5.3 3.4 166 9 165 165 2 0 2.3 1.8 01/02/2006 08:30:00 4.1 0.3 4.6 3.4 4 0.2 4.6 3.4 4.1 0.3 4.9 3.4 162 7 168 165 1.9 0 2.1 1.8 01/02/2006 08:40:00 4.2 0.3 4.6 3.4 4.1 0.3 4.6 3.4 4.2 0.2 4.9 3.4 156 3 156 165 1.9 0 2.1 1.8 01/02/2006 08:50:00 4.6 0.3 5.3 3.8 4.5 0.3 5.3 3.8 4.6 0.3 5.3 3.8 153 3 157 165 1.9 0 2.1 1.8 01/02/2006 09:00:00 4.4 0.4 5.3 3.4 4.4 0.4 5.3 3.4 4.4 0.4 5.3 3.4 152 4 155 165 1.9 0 1.8 1.8 01/02/2006 09:10:00 4.4 0.4 5.3 3.4 4.4 0.4 5.3 3.4 4.4 0.4 5.3 3.4 150 4 148 165 1.9 0 1.8 1.8 01/02/2006 09:20:00 5.6 0.4 7.2 4.2 5.6 0.4 6.8 4.6 5.7 0.4 6.8 4.6 153 6 157 165 1.9 0 2.3 1.8 01/02/2006 09:30:00 6.1 0.6 7.2 4.2 5.9 0.5 7.2 4.2 6 0.6 7.2 3.8 164 12 165 165 1.7 0 1.8 1.6 01/02/2006 09:40:00 5 0.4 6.5 3.8 4.9 0.4 6.1 3.8 4.9 0.5 6.1 3.8 170 4 209 165 1.6 0 1.8 1.6 01/02/2006 09:50:00 3.8 0.6 4.9 2.3 3.7 0.5 4.6 2.6 3.8 0.5 4.6 2.6 172 0 172 165 1.6 0 1.6 1.6 01/02/2006 10:00:00 2.5 0.3 3.4 1.9 2.6 0.3 3.4 1.9 2.5 0.3 3 1.9 172 0 172 165 1.6 0 1.6 1.4 01/02/2006 10:10:00 2.2 0.3 2.6 1.5 2.4 0.3 3 1.5 2.3 0.2 2.6 1.5 172 0 172 165 1.5 0 1.8 1.4 01/02/2006 10:20:00 2.1 0.2 2.3 1.5 2.2 0.2 2.6 1.5 2.1 0.2 2.6 1.5 172 0 173 165 1.5 0 1.6 1.4 01/02/2006 10:30:00 2.3 0.5 3.4 1.5 2.4 0.4 3.4 1.5 2.1 0.4 3 1.5 172 0 173 165 1.4 0 1.6 1.4 01/02/2006 10:40:00 3.2 0.3 4.2 2.3 3.3 0.3 4.2 2.6 2.9 0.3 3.8 2.3 172 0 172 165 1.4 0 1.4 1.4 01/02/2006 10:50:00 3.2 0.4 4.6 2.6 3.4 0.3 4.6 2.6 3.1 0.4 4.2 2.3 172 0 172 165 1.4 0 1.6 1.4 01/02/2006 11:00:00 3 0.5 4.6 1.9 3.2 0.5 4.6 2.3 3 0.5 4.6 2.3 172 0 172 165 1.4 0 1.6 1.4 01/02/2006 11:10:00 3.4 0.4 4.2 2.6 3.5 0.3 4.2 2.6 3.2 0.4 4.2 2.3 172 0 172 165 1.5 0 1.6 1.4 01/02/2006 11:20:00 3.5 0.3 4.6 2.6 3.6 0.3 4.6 3 3.5 0.4 4.6 2.6 172 0 172 165 1.6 0 1.6 1.6 01/02/2006 11:30:00 3.8 0.6 4.9 2.3 3.9 0.6 4.9 2.6 3.8 0.6 4.9 1.9 172 0 172 165 1.6 0 1.6 1.6 01/02/2006 11:40:00 3.9 0.3 4.6 3 4 0.3 4.9 3.4 3.9 0.3 4.9 3 172 0 172 165 1.6 0 1.8 1.6 01/02/2006 11:50:00 4.2 0.3 4.9 3.4 4.2 0.3 4.9 3.4 4.4 0.3 5.3 3.8 172 0 172 165 1.6 0 1.6 1.6 01/02/2006 12:00:00 4.4 0.4 5.7 3.4 4.4 0.4 5.7 3.4 4.6 0.4 5.7 3.4 172 0 172 165 1.6 0 1.8 1.6 01/02/2006 12:10:00 4.7 0.4 5.7 3.8 4.7 0.4 5.7 3.8 4.9 0.4 6.1 3.8 172 0 172 165 1.6 0 1.8 1.6 01/02/2006 12:20:00 4.6 0.4 5.7 3.8 4.6 0.4 5.3 3.8 4.8 0.4 5.7 3.8 172 0 172 165 1.6 0 1.6 1.6 01/02/2006 12:30:00 4.6 0.5 6.1 3.4 4.6 0.4 6.1 3.8 4.5 0.4 5.7 3.4 172 0 172 165 1.6 0 1.8 1.6 01/02/2006 12:40:00 5.2 0.6 6.5 3.8 5.2 0.6 6.5 3.8 5.5 0.6 6.8 4.2 172 0 172 165 1.6 0 1.8 1.4 01/02/2006 12:50:00 5.4 0.5 6.5 4.2 5.5 0.4 6.5 4.2 5.6 0.4 6.8 4.2 172 0 172 165 1.6 0 1.8 1.6 01/02/2006 13:00:00 5.5 0.5 6.5 3.8 5.6 0.4 6.5 4.2 5.8 0.4 6.8 4.6 172 0 172 165 1.6 0 1.6 1.6 01/02/2006 13:10:00 4.6 0.5 6.1 3.4 4.9 0.4 6.5 3.4 4.9 0.4 6.1 3.4 172 0 172 165 1.6 0 1.8 1.4 01/02/2006 13:20:00 4.3 0.7 6.1 2.6 4.4 0.7 6.1 2.6 4.5 0.7 6.1 2.3 172 0 172 165 1.6 0 1.8 1.6 01/02/2006 13:30:00 3.7 0.6 4.9 1.9 3.9 0.6 5.3 2.3 3.8 0.6 5.3 2.3 172 0 172 165 1.6 0 1.8 1.4 01/02/2006 13:40:00 4 0.6 5.3 2.6 4 0.5 5.7 3 3.9 0.5 5.7 2.6 173 1 174 165 1.7 0 1.8 1.6 01/02/2006 13:50:00 4.3 0.6 5.7 2.3 4.2 0.6 5.7 2.6 4.2 0.5 5.7 2.6 177 9 162 165 1.7 0 1.8 1.6 01/02/2006 14:00:00 4.9 0.5 6.1 3.8 4.5 0.4 5.7 3.4 4.7 0.5 6.1 3.8 177 6 183 165 1.7 0 1.8 1.6 01/02/2006 14:10:00 4.4 0.6 6.1 3 4 0.5 5.7 2.6 4.2 0.5 5.3 3.4 173 8 190 165 1.6 0 1.8 1.6 01/02/2006 14:20:00 4.8 0.6 6.5 3.4 4.5 0.6 6.5 3.4 4.5 0.5 6.5 3.4 173 0 173 165 1.6 0 1.8 1.6 01/02/2006 14:30:00 5.7 0.7 7.6 3.4 5.3 0.7 6.8 3.4 5.5 0.6 7.2 3.8 171 3 171 165 1.7 0 1.8 1.4 01/02/2006 14:40:00 6.2 0.5 7.6 4.9 5.6 0.5 6.8 4.6 6.3 0.5 7.6 4.9 173 4 176 165 1.8 0 1.8 1.6 01/02/2006 14:50:00 5.5 0.4 6.5 4.6 4.9 0.4 5.7 3.8 5.5 0.4 6.5 4.2 175 2 174 165 1.9 0 2.1 1.8 01/02/2006 15:00:00 5.2 0.6 7.6 3.8 4.8 0.6 7.6 3.4 5.4 0.6 7.2 4.2 179 8 181 165 2 0 2.3 1.8 01/02/2006 15:10:00 4.5 0.4 5.3 3.4 4.1 0.4 4.9 3 4.7 0.5 5.7 3 178 7 172 165 2.1 0 2.3 1.8 01/02/2006 15:20:00 4.5 0.8 6.8 3 4.1 0.8 6.5 2.6 4.8 0.8 7.2 3.4 171 11 165 165 2.1 0 2.3 1.8 01/02/2006 15:30:00 5.4 0.7 8 3.4 5 0.6 7.2 3.8 5.6 0.6 7.6 4.2 172 8 180 165 2 0 2.3 1.6 01/02/2006 15:40:00 5.5 0.6 6.8 4.2 5.1 0.6 6.5 3.4 5.9 0.7 7.6 4.2 166 4 165 165 1.5 0 1.8 1.4 01/02/2006 15:50:00 5 0.8 6.8 3.4 4.8 0.7 6.1 3.4 5.4 0.7 7.2 4.2 165 0 165 165 1.6 0 1.8 1.4 01/02/2006 16:00:00 4.1 0.5 5.3 3 3.9 0.4 5.3 3 4.5 0.4 6.1 3.4 165 0 165 165 1.5 0 1.6 1.4 01/02/2006 16:10:00 4.8 0.5 6.1 3.4 4.5 0.5 5.7 3.4 5.1 0.5 6.5 3.8 165 0 165 165 1.5 0 1.8 1.4 01/02/2006 16:20:00 5 0.6 6.5 3.8 4.9 0.6 6.1 3.4 5.5 0.6 6.8 4.2 165 0 165 165 1.3 0 1.6 1.1 01/02/2006 16:30:00 6 0.8 8 3.8 6 0.7 7.6 3.8 6.4 0.8 8 4.6 165 0 165 165 1.1 0 1.4 0.9 01/02/2006 16:40:00 5.9 0.5 7.2 4.6 5.9 0.5 7.2 4.6 6.3 0.6 8 4.6 165 0 165 165 1.1 0 1.4 0.9 01/02/2006 16:50:00 5.7 0.5 7.2 4.2 5.6 0.5 6.8 4.2 6 0.6 7.2 4.6 165 0 165 165 0.9 0 1.4 0.9 01/02/2006 17:00:00 5.4 0.5 6.8 3.8 5.3 0.5 6.5 3.8 5.8 0.6 7.2 4.2 165 0 165 165 0.9 0 1.1 0.9 01/02/2006 17:10:00 4.6 0.4 5.3 3.4 4.6 0.4 5.3 3.8 4.9 0.4 6.1 3.4 165 0 165 165 0.9 0 1.1 0.9 01/02/2006 17:20:00 4.8 0.4 5.3 3.4 4.8 0.4 5.3 3.4 5.2 0.4 6.1 3.8 165 0 165 165 1.1 0 1.1 0.9 01/02/2006 17:30:00 5 0.5 6.1 3.8 5.1 0.5 6.1 3.8 5.5 0.5 6.5 4.6 165 0 165 165 1 0 1.1 0.9 01/02/2006 17:40:00 5.3 0.3 6.1 4.2 5.5 0.3 6.1 4.6 5.9 0.4 6.8 4.9 165 0 165 165 1.1 0 1.4 0.9 01/02/2006 17:50:00 4.7 0.4 5.3 3.8 4.9 0.4 5.7 3.8 5.1 0.5 6.1 4.2 166 10 165 165 0.9 0 1.4 0.9 01/02/2006 18:00:00 4 0.4 4.9 3 4.3 0.3 4.9 3 4.6 0.4 5.3 3.8 164 0 163 165 0.8 0 0.9 0.9 01/02/2006 18:10:00 4.1 0.3 4.9 3.4 4.3 0.3 5.3 3.4 4.5 0.3 4.9 3.8 164 0 164 165 0.9 0 1.1 0.9 01/02/2006 18:20:00 4.6 0.4 5.7 3.4 4.9 0.4 5.7 3.8 4.8 0.4 5.7 3.8 164 0 164 165 0.9 0 1.1 0.9 01/02/2006 18:30:00 4.5 0.3 5.3 3.4 4.9 0.3 5.7 3.8 4.8 0.4 5.7 3.8 163 3 164 165 0.9 0 1.1 0.9 01/02/2006 18:40:00 4.4 0.4 5.3 3.4 4.8 0.3 5.7 3.8 4.7 0.3 5.7 4.2 156 5 157 165 1.1 0 1.4 0.9 01/02/2006 18:50:00 5.2 0.9 7.6 3.8 5.5 0.9 7.6 4.2 5.6 1.1 8 4.2 162 10 167 165 1.2 0 1.4 1.1 01/02/2006 19:00:00 5.8 1.7 9.1 3 5.9 1.8 9.5 3 5.9 1.9 9.9 3 156 14 148 165 0.8 0.2 1.4 0.4 01/02/2006 19:10:00 3.2 0.6 4.6 1.5 3.1 0.6 4.6 1.5 3 0.6 4.2 1.9 160 8 150 165 0.4 0 0.7 0.2 01/02/2006 19:20:00 4.3 0.2 4.9 3.4 4.3 0.2 4.9 3.8 4.2 0.3 4.6 3.4 172 2 173 165 0.7 0.1 0.9 0.7 01/02/2006 19:30:00 4 0.3 4.9 3.4 4.1 0.3 4.9 3.4 4.1 0.3 5.3 3.4 170 4 163 165 0.9 0 1.1 0.9 01/02/2006 19:40:00 3.4 0.3 4.2 2.6 3.5 0.3 4.2 2.3 3.4 0.3 4.2 2.3 162 5 164 165 1 0 1.4 0.9 01/02/2006 19:50:00 3.6 0.6 5.7 2.3 3.7 0.7 6.1 2.3 3.7 0.6 5.3 2.6 145 9 128 165 0.9 0 1.4 0.9 01/02/2006 20:00:00 3.7 0.7 5.3 1.5 3.7 0.7 4.9 1.9 3.6 0.6 4.9 1.9 156 9 165 165 0.8 0 1.1 0.9 01/02/2006 20:10:00 3.2 0.5 4.6 1.9 3.2 0.5 4.2 2.3 3.2 0.6 4.6 2.3 162 5 165 165 0.8 0 1.1 0.9 01/02/2006 20:20:00 3.4 0.9 5.7 1.9 3.4 0.9 5.7 1.5 3.4 1 5.7 1.9 166 6 162 165 0.8 0 1.1 0.9 01/02/2006 20:30:00 4.1 0.7 5.7 2.6 4.1 0.7 5.7 2.6 4.2 0.8 6.8 2.6 163 6 166 165 1.1 0 1.4 0.9 01/02/2006 20:40:00 4.4 0.7 6.1 2.6 4.4 0.7 6.1 3 4.5 0.7 6.1 2.6 159 11 142 165 1.1 0 1.4 0.9 01/02/2006 20:50:00 5.3 0.8 7.2 3.4 5.3 0.7 7.6 3.4 5.3 0.8 6.8 3.8 168 6 167 165 1.1 0 1.4 0.9 01/02/2006 21:00:00 4.7 0.9 6.8 2.6 4.6 0.8 6.8 2.6 4.7 0.7 6.8 3 161 11 164 165 1.1 0 1.4 1.1 01/02/2006 21:10:00 5.1 0.7 6.8 3.4 5.1 0.7 6.8 3.4 5 0.6 7.2 3.4 155 8 164 165 1.1 0 1.4 0.9 01/02/2006 21:20:00 5 0.7 7.6 3 4.9 0.8 7.2 2.6 5 0.7 6.5 2.6 153 8 155 165 1.1 0 1.4 0.9 01/02/2006 21:30:00 4.8 0.6 6.5 3.4 4.7 0.6 6.1 3.4 4.7 0.7 6.1 3.4 157 8 158 165 1.1 0 1.4 0.9 01/02/2006 21:40:00 4.4 0.8 6.5 3 4.4 0.7 6.5 2.6 4.4 0.7 6.1 2.6 158 7 164 165 1 0 1.4 0.9 01/02/2006 21:50:00 3.8 0.5 4.9 2.6 3.8 0.5 4.9 3 3.8 0.5 4.9 2.6 157 8 165 165 0.8 0 1.1 0.9 01/02/2006 22:00:00 3.5 0.5 4.6 2.3 3.5 0.5 4.6 2.3 3.5 0.5 4.9 2.6 147 11 164 165 1.1 0 1.4 0.9 01/02/2006 22:10:00 4 0.9 6.1 1.9 4.1 0.9 6.1 2.3 4 0.8 6.1 2.3 147 9 140 165 1.1 0 1.4 0.9 01/02/2006 22:20:00 5.1 0.7 6.8 3.8 5.1 0.6 6.8 3.8 4.9 0.6 6.5 3.4 149 9 147 165 1.2 0 1.4 0.9 01/02/2006 22:30:00 4.9 0.8 6.8 3.4 4.9 0.8 6.8 3 4.8 0.8 6.5 3 149 8 155 165 1.3 0 1.6 1.1 01/02/2006 22:40:00 4.5 0.7 6.1 1.9 4.5 0.6 5.7 2.3 4.3 0.6 5.7 2.3 152 8 150 165 1.4 0 1.6 1.4 01/02/2006 22:50:00 4.1 0.7 6.5 2.3 4 0.7 6.5 2.3 3.9 0.8 6.1 1.9 148 7 151 165 1.2 0 1.6 1.1 01/02/2006 23:00:00 3.7 0.5 4.9 2.6 3.7 0.5 4.9 2.6 3.6 0.5 4.9 2.6 154 7 153 165 1.2 0 1.4 0.9 01/02/2006 23:10:00 4.6 0.8 6.5 3 4.6 0.8 6.5 3 4.4 0.8 6.5 2.6 140 7 133 165 1.2 0.1 1.4 0.9 01/02/2006 23:20:00 5.7 0.6 7.2 4.2 5.8 0.5 6.8 4.2 5.7 0.5 6.8 4.2 144 6 150 165 1.4 0 1.4 1.4 01/02/2006 23:30:00 4.9 0.6 6.1 3 4.9 0.6 6.5 3.4 4.9 0.6 6.1 3.4 149 5 141 165 1.3 0 1.6 1.4 01/02/2006 23:40:00 3.9 0.5 5.3 1.1 3.9 0.5 5.3 1.5 3.9 0.5 5.3 2.3 154 9 156 165 1.2 0 1.4 1.1 01/02/2006 23:50:00 3.5 0.5 4.9 1.9 3.5 0.5 4.9 1.9 3.5 0.5 4.6 2.3 154 9 156 165 1.3 0 1.4 1.4 01/03/2006 00:00:00 4.3 0.8 6.5 2.6 4.3 0.8 6.1 3 4.2 0.8 6.5 2.6 161 11 165 165 1.2 0 1.6 1.1 01/03/2006 00:10:00 4.3 1.2 7.2 1.1 4.3 1.2 7.2 1.1 4.4 1.2 7.2 1.1 168 10 163 165 1.1 0.2 1.4 0.9 01/03/2006 00:20:00 2.7 0.7 4.2 1.1 2.6 0.7 4.2 0.7 2.3 0.5 4.2 1.1 181 12 166 165 0.7 0 0.9 0.7 01/03/2006 00:30:00 3.9 0.5 4.9 2.3 3.9 0.5 4.9 2.3 4 0.5 5.3 2.6 163 5 161 165 1.1 0.2 1.4 0.7 01/03/2006 00:40:00 3.1 0.6 4.9 1.5 3.1 0.6 4.9 1.1 3.1 0.5 4.2 1.9 155 9 145 165 1.2 0 1.4 1.1 01/03/2006 00:50:00 4.1 0.5 5.3 2.3 4.1 0.5 5.3 1.9 3.9 0.5 4.9 2.6 137 8 138 165 1.3 0.1 1.6 1.1 01/03/2006 01:00:00 3.9 0.6 5.3 1.9 3.9 0.7 5.3 2.3 3.7 0.6 4.9 1.9 139 8 136 165 1.5 0 1.8 1.4 01/03/2006 01:10:00 3.6 0.6 4.9 2.3 3.6 0.6 4.9 1.9 3.5 0.6 4.9 1.9 142 7 142 165 1.5 0 1.8 1.4 01/03/2006 01:20:00 3.2 0.6 4.9 2.3 3.3 0.6 4.9 2.3 3.2 0.5 4.6 1.9 143 9 130 165 1.6 0 1.6 1.4 01/03/2006 01:30:00 3.7 0.8 5.3 1.9 3.6 0.7 5.3 2.3 3.7 1 5.7 1.9 171 17 179 165 0.9 0.2 1.6 0.7 01/03/2006 01:40:00 3.2 0.5 4.2 1.5 3.1 0.5 4.2 1.9 3.2 0.5 4.2 1.5 200 18 201 165 0.6 0 0.9 0.2 01/03/2006 01:50:00 1.8 0.8 3.4 0.4 1.9 0.8 3.8 0.4 2.1 0.7 3.8 0.4 221 16 241 165 0.4 0.1 0.9 0.2 01/03/2006 02:00:00 0.6 0.4 1.9 0.4 0.7 0.4 1.9 0.4 0.8 0.5 2.3 0.4 161 38 214 165 0.8 0 1.1 0.9 01/03/2006 02:10:00 4.3 0.9 6.8 1.9 4.4 0.9 6.8 1.5 4.1 0.9 6.5 1.5 104 8 106 165 1.1 0 1.4 0.9 01/03/2006 02:20:00 3.7 0.7 5.3 1.9 3.8 0.7 5.3 2.3 3.7 0.7 5.3 1.9 114 12 99 165 0.8 0 1.1 0.7 01/03/2006 02:30:00 1.5 0.9 3.4 0.4 1.4 0.9 3.4 0.4 1.6 0.8 3.4 0.4 163 26 150 165 0.6 0 0.9 0.7 01/03/2006 02:40:00 1.3 0.6 3.4 0.4 1.3 0.6 3 0.4 1.4 0.5 3 0.4 210 43 119 165 0.3 0.1 0.7 0.2 01/03/2006 02:50:00 2.4 1 4.6 0.4 2.4 0.9 4.6 0.4 2.4 0.9 4.9 0.4 157 15 165 165 0.7 0.2 1.1 0.2 01/03/2006 03:00:00 3 0.6 4.6 1.5 3.1 0.5 4.6 1.9 2.9 0.5 4.2 1.5 149 13 138 165 1.1 0 1.4 0.9 01/03/2006 03:10:00 2.7 0.4 3.8 1.5 2.8 0.4 3.8 1.5 2.6 0.4 3.8 1.5 141 10 128 165 1.2 0 1.4 0.9 01/03/2006 03:20:00 2.5 0.3 3.4 1.5 2.5 0.3 3.4 1.9 2.2 0.3 3 1.5 142 5 145 165 1.1 0 1.4 0.9 01/03/2006 03:30:00 2.8 0.6 4.2 1.1 2.9 0.7 4.2 1.1 2.5 0.6 3.8 1.1 135 6 132 165 1.2 0.1 1.4 0.9 01/03/2006 03:40:00 2.1 0.5 3 0.7 2 0.5 3 0.7 1.9 0.5 3 0.7 151 11 142 165 1 0.1 1.4 0.9 01/03/2006 03:50:00 2.5 0.5 3.8 1.5 2.4 0.5 3.8 1.1 2.3 0.4 3.4 1.5 156 8 154 165 1.1 0 1.4 0.9 01/03/2006 04:00:00 1.6 0.4 2.3 0.4 1.5 0.4 2.3 0.4 1.5 0.5 2.3 0.4 161 8 165 165 0.9 0 1.4 0.9 01/03/2006 04:10:00 0.9 0.7 2.6 0.4 0.8 0.7 2.6 0.4 0.9 0.6 2.3 0.4 130 6 128 165 1.1 0 1.4 0.9 01/03/2006 04:20:00 2 0.9 3.4 0.4 2.1 1 3.8 0.4 1.9 0.8 3.4 0.4 102 8 102 165 1.3 0 1.4 1.4 01/03/2006 04:30:00 2.5 0.5 3.8 1.5 2.6 0.6 3.8 1.5 2.4 0.4 3.4 1.5 98 4 94 165 1.2 0 1.6 1.1 01/03/2006 04:40:00 4.3 0.4 5.3 3.4 4.4 0.4 5.3 3 4 0.5 4.9 2.6 102 5 103 165 1.2 0 1.4 1.1 01/03/2006 04:50:00 4.3 0.4 5.3 3.4 4.5 0.4 5.3 3.4 4.1 0.4 4.9 3 101 3 106 165 1.2 0 1.4 0.9 01/03/2006 05:00:00 4.2 0.3 4.9 3.4 4.3 0.3 4.9 3.4 4 0.3 4.6 2.6 100 4 106 165 1 0 1.4 0.9 01/03/2006 05:10:00 3.4 0.2 4.2 3 3.7 0.2 4.2 3 3.5 0.2 3.8 3 88 3 87 165 1.1 0 1.4 0.9 01/03/2006 05:20:00 3.4 0.4 4.2 2.3 3.7 0.5 4.2 2.3 3.4 0.5 4.2 1.9 86 12 95 165 0.8 0 0.9 0.7 01/03/2006 05:30:00 2 0.6 3.4 0.4 2.1 0.6 3.4 0.4 2.2 0.5 3 0.7 45 13 60 165 0.8 0 0.9 0.7 01/03/2006 05:40:00 2.4 0.7 3.8 0.4 2.5 0.8 3.8 0.4 2.1 0.7 3 0.4 90 18 95 165 0.9 0.1 1.4 0.9 01/03/2006 05:50:00 2.8 0.2 3.4 2.3 2.9 0.2 3.4 2.3 2.6 0.2 3 1.9 98 3 92 165 1.5 0 1.6 1.4 01/03/2006 06:00:00 3 0.6 4.6 1.1 3.1 0.6 4.6 1.5 2.4 0.6 4.2 0.7 85 9 85 165 1.2 0.2 1.8 0.9 01/03/2006 06:10:00 4 0.8 4.9 1.9 4.2 0.8 5.3 2.3 3.8 1 5.3 1.1 90 16 90 165 1.3 0.3 1.8 0.9 01/03/2006 06:20:00 5.3 0.5 6.5 4.2 5.5 0.5 6.8 4.6 5.3 0.6 6.5 3.8 96 4 96 165 1.8 0 1.8 1.6 01/03/2006 06:30:00 4.9 0.3 5.7 4.2 5.1 0.3 6.1 4.2 4.9 0.4 5.7 3.8 91 4 92 165 2.1 0 2.3 1.8 01/03/2006 06:40:00 4.6 0.3 5.7 3.8 4.8 0.3 5.7 4.2 4.6 0.4 5.7 3.8 86 5 82 165 2.1 0 2.3 1.8 01/03/2006 06:50:00 4.5 0.4 5.7 3 4.7 0.4 5.7 3.4 4.4 0.6 5.7 2.3 88 6 88 165 2.2 0 2.3 1.8 01/03/2006 07:00:00 4.5 0.5 5.3 2.6 4.6 0.5 5.7 3 3.9 0.6 5.3 2.3 83 6 79 165 1.9 0 2.3 1.8 01/03/2006 07:10:00 3 0.7 4.9 1.5 3.2 0.7 4.9 1.1 2.5 0.5 4.6 1.5 67 17 88 165 1.8 0 1.8 1.6 01/03/2006 07:20:00 2.3 0.6 3.8 0.4 2.3 0.6 3.8 0.4 2.4 0.6 3.8 0.7 44 12 39 165 1.8 0 1.8 1.6 01/03/2006 07:30:00 3.9 1.3 6.8 1.5 4 1.3 7.6 1.1 3.7 1.3 6.1 1.1 91 39 102 165 1.8 0.2 1.8 1.4 01/03/2006 07:40:00 4.4 0.8 6.8 3 4.3 0.8 6.8 2.6 4.2 0.7 6.5 3 145 10 130 165 1.3 0.1 1.6 0.9 01/03/2006 07:50:00 4.3 1.5 6.5 1.5 4.3 1.5 6.8 1.1 4 1.4 6.8 1.5 133 17 107 165 1.1 0.1 1.4 0.9 01/03/2006 08:00:00 3.8 0.6 5.3 2.3 3.9 0.6 5.3 2.6 3.5 0.7 5.3 2.3 124 8 121 165 1.4 0 1.6 1.4 01/03/2006 08:10:00 4.4 0.9 6.5 1.9 4.5 0.9 6.8 2.3 4.2 0.8 5.7 1.9 117 9 119 165 1.4 0 1.6 1.4 01/03/2006 08:20:00 4.7 0.6 6.1 3.4 4.8 0.6 6.5 3.4 4.4 0.7 6.5 3 100 8 105 165 1.5 0 1.6 1.4 01/03/2006 08:30:00 4.2 0.7 5.7 2.3 4.4 0.7 5.7 2.3 3.9 0.6 5.3 2.3 68 13 82 165 1.4 0 1.6 1.4 01/03/2006 08:40:00 2.9 0.5 4.6 1.9 2.8 0.5 4.6 1.5 2.8 0.4 4.2 1.5 36 14 19 165 1.2 0 1.4 1.1 01/03/2006 08:50:00 2.5 0.8 3.8 0.7 2.2 0.9 3.8 0.4 2.6 0.9 4.2 0.4 27 22 15 165 1.1 0 1.4 0.9 01/03/2006 09:00:00 2.7 1.3 5.7 0.4 2.6 1.3 5.7 0.4 2.4 1 4.9 0.4 74 33 95 165 1.2 0.1 1.6 0.9 01/03/2006 09:10:00 5.8 0.6 7.2 3.8 6 0.7 7.6 3.8 5.4 0.7 6.8 3 92 6 91 165 1.5 0 1.6 1.4 01/03/2006 09:20:00 6.3 1 8.4 3.4 6.5 1 8.8 3.4 6 1 8.4 3.4 77 12 83 165 1.4 0 1.6 1.4 01/03/2006 09:30:00 5.1 2 9.9 2.3 5.2 2 9.9 2.3 4.8 1.9 9.5 1.5 74 17 98 165 1.4 0 1.6 1.1 01/03/2006 09:40:00 5 1.1 8 2.6 5.1 1.2 8.4 2.6 4.6 1.1 7.6 2.3 105 10 109 165 1.6 0 1.8 1.6 01/03/2006 09:50:00 5.6 1.3 8 1.9 5.8 1.3 8.4 2.3 5.1 1.4 7.6 2.3 91 15 93 165 1.7 0 1.8 1.6 01/03/2006 10:00:00 5.7 1.7 8 1.1 5.8 1.9 8 1.1 5.5 1.7 8 1.5 120 16 98 165 2.1 0 2.3 1.8 01/03/2006 10:10:00 2.8 1.2 4.9 0.4 2.7 1.2 4.9 0.4 2.4 1.1 4.6 0.4 102 15 102 165 2.1 0 2.3 1.8 01/03/2006 10:20:00 2.6 0.4 3.4 1.5 2.6 0.4 3.8 1.5 2.4 0.4 3.4 1.5 99 9 78 165 2.3 0 2.6 2.3 01/03/2006 10:30:00 3.9 0.6 5.7 2.6 3.9 0.6 6.1 2.3 3.4 0.6 5.3 2.3 93 9 87 165 2.5 0 2.6 2.6 01/03/2006 10:40:00 5 0.5 6.8 3.4 5.2 0.6 6.8 3.4 4.7 0.5 6.5 3.4 102 5 98 165 2.7 0 2.8 2.6 01/03/2006 10:50:00 5.4 0.5 6.5 4.2 5.6 0.5 6.5 4.2 5.2 0.5 6.5 3.8 99 8 102 165 3 0 3.3 2.8 01/03/2006 11:00:00 5.5 1.1 8.4 3 5.6 1.2 8.4 3 4.9 1.2 7.6 2.6 78 10 94 165 2.9 0.1 3.3 2.6 01/03/2006 11:10:00 7 1 9.9 4.2 7.2 1 9.9 3.8 6.6 1 9.9 3.8 78 9 87 165 3.2 0 3.3 3 01/03/2006 11:20:00 6.6 1.3 9.5 3.4 6.7 1.3 9.5 3.4 6.3 1.3 9.1 2.6 85 10 84 165 3.1 0 3.3 3 01/03/2006 11:30:00 8.5 0.8 9.9 6.1 8.7 0.8 10.3 6.1 8 0.9 9.9 5.7 91 5 94 165 3.2 0 3.5 3 01/03/2006 11:40:00 7.8 0.7 9.5 5.7 8 0.7 9.5 5.7 7.2 0.9 9.1 4.2 88 6 97 165 3.4 0 3.5 3.3 01/03/2006 11:50:00 7.7 0.9 10.3 3.8 7.9 0.9 10.3 3.8 7.1 1.1 9.1 3.8 90 6 98 165 3.5 0 3.5 3.5 01/03/2006 12:00:00 3.7 1.2 7.2 1.1 3.8 1.2 7.2 0.7 3.4 1.1 6.8 1.1 85 23 103 165 3 0.2 3.5 2.8 01/03/2006 12:10:00 4.4 1 6.1 2.3 4.4 1 6.5 1.9 4.2 0.9 6.5 2.3 89 11 99 165 3.1 0 3.3 2.8 01/03/2006 12:20:00 4.7 0.5 6.1 3.4 4.8 0.6 6.1 3 4.4 0.6 5.7 2.6 96 8 96 165 3.3 0 3.5 3.3 01/03/2006 12:30:00 4.8 0.6 6.1 3 4.9 0.7 6.5 3 4.6 0.7 6.1 3 82 9 80 165 3.4 0 3.5 3.3 01/03/2006 12:40:00 5.6 0.6 7.6 3.8 5.7 0.7 7.6 3.8 5.3 0.7 7.6 3.4 83 9 80 165 3.5 0 3.8 3.5 01/03/2006 12:50:00 5.4 0.7 7.2 3.8 5.5 0.7 7.2 3.8 5 0.7 7.2 3.4 77 10 73 165 3.6 0 3.8 3.5 01/03/2006 13:00:00 5.1 0.8 7.2 3 5.2 0.8 7.2 3.4 4.7 0.8 6.8 2.6 73 9 77 165 3.5 0 3.5 3.5 01/03/2006 13:10:00 6.6 0.8 8.8 4.6 6.8 0.8 8.8 4.6 6.3 0.9 8.8 4.2 81 5 83 165 3.6 0 3.8 3.5 01/03/2006 13:20:00 6.1 0.7 7.6 4.2 6.2 0.7 7.6 4.6 5.8 0.6 7.2 4.6 76 6 92 165 3.6 0 3.8 3.5 01/03/2006 13:30:00 6.4 0.7 8.4 4.6 6.5 0.7 8 4.9 6 0.6 7.6 4.6 77 6 87 165 3.5 0 3.5 3.5 01/03/2006 13:40:00 7.2 0.5 8 5.7 7.4 0.5 8.4 5.7 6.8 0.5 8.4 5.3 80 3 81 165 3.6 0 3.5 3.5 01/03/2006 13:50:00 6.9 0.5 8 5.7 7.1 0.5 8.4 6.1 6.7 0.5 7.6 5.3 78 4 84 165 3.6 0 3.5 3.5 01/03/2006 14:00:00 6.7 0.6 8 4.6 6.9 0.6 8.4 4.2 6.3 0.7 8 3.8 75 5 85 165 3.6 0 3.8 3.5 01/03/2006 14:10:00 7 0.6 8.8 5.3 7.2 0.6 8.8 5.7 6.5 0.7 8.4 4.9 82 6 84 165 3.5 0 3.5 3.5 01/03/2006 14:20:00 7.3 0.6 8.8 5.7 7.5 0.6 8.8 5.7 6.9 0.6 8.4 4.9 82 5 84 165 3.5 0 3.5 3.5 01/03/2006 14:30:00 7.5 0.7 9.1 5.3 7.7 0.8 9.1 5.7 7 0.8 9.1 4.9 83 5 91 165 3.5 0 3.5 3.5 01/03/2006 14:40:00 7.4 0.6 8.8 5.3 7.5 0.6 8.8 5.7 6.9 0.7 8.4 5.3 81 6 82 165 3.5 0 3.5 3.5 01/03/2006 14:50:00 6.9 0.7 8.4 4.9 7.2 0.7 8.8 4.9 6.5 0.7 8 4.6 80 6 81 165 3.5 0 3.5 3.5 01/03/2006 15:00:00 7 0.7 8.4 4.9 7.2 0.7 8.8 5.3 6.6 0.8 8.4 4.9 77 5 84 165 3.5 0 3.5 3.5 01/03/2006 15:10:00 7.1 0.7 8.8 4.9 7.3 0.7 8.8 4.9 6.8 0.7 8.4 4.9 78 5 81 165 3.5 0 3.8 3.5 01/03/2006 15:20:00 6.3 0.7 8 4.6 6.4 0.7 8 4.6 6 0.6 7.2 4.6 73 5 75 165 3.5 0 3.5 3.5 01/03/2006 15:30:00 6.7 0.8 8.4 4.2 6.9 0.8 8.8 4.6 6.4 0.7 8 4.6 79 6 85 165 3.4 0 3.5 3.3 01/03/2006 15:40:00 7.4 0.5 8.4 5.7 7.6 0.5 8.8 6.1 7.1 0.6 8.4 5.7 78 4 82 165 3.5 0 3.5 3.3 01/03/2006 15:50:00 6.8 0.8 8.8 4.9 7 0.8 9.5 4.9 6.4 0.7 8.8 4.6 73 6 76 165 3.5 0 3.5 3.5 01/03/2006 16:00:00 6.4 0.6 8 4.6 6.6 0.7 8.4 4.6 6 0.7 7.6 4.2 73 6 75 165 3.4 0 3.5 3.3 01/03/2006 16:10:00 6.6 0.6 8 4.6 6.8 0.6 8.4 4.9 6.3 0.7 8 4.6 74 5 77 165 3.5 0 3.5 3.3 01/03/2006 16:20:00 6.1 0.6 7.6 4.6 6.3 0.6 7.6 4.9 5.8 0.6 7.2 4.2 74 6 75 165 3.4 0 3.5 3.3 01/03/2006 16:30:00 5.7 0.6 7.2 4.2 5.8 0.7 7.2 3.8 5.3 0.5 6.8 3.8 71 7 78 165 3.4 0 3.5 3.3 01/03/2006 16:40:00 5 0.6 6.8 3.4 5.1 0.6 6.8 3.4 4.7 0.6 6.5 3 65 8 80 165 3.3 0 3.5 3.3 01/03/2006 16:50:00 4.6 0.6 6.1 3 4.7 0.6 6.5 3 4.4 0.5 5.7 3 63 7 63 165 3.3 0 3.5 3.3 01/03/2006 17:00:00 4.8 0.6 6.5 3.4 4.9 0.6 6.5 3.4 4.6 0.6 6.1 3 59 7 73 165 3.2 0 3.5 3.3 01/03/2006 17:10:00 4.6 0.4 5.7 3.4 4.6 0.5 6.1 3 4.3 0.5 5.7 3 53 6 53 165 3.1 0 3.3 3 01/03/2006 17:20:00 4 0.4 5.7 3 4 0.4 5.7 3 3.8 0.4 4.9 2.6 46 5 58 165 3.1 0 3.3 3 01/03/2006 17:30:00 3.7 0.3 4.6 3 3.7 0.3 4.6 3 3.5 0.4 4.6 2.3 41 4 44 165 3.1 0 3.3 3 01/03/2006 17:40:00 5.1 1.3 8.8 3 5.1 1.3 8.8 3 4.8 1.3 8.4 2.6 56 9 62 165 3.2 0 3.3 3 01/03/2006 17:50:00 5.8 0.6 7.2 3.8 5.9 0.7 7.2 3.8 5.5 0.7 7.2 3.8 55 7 53 165 2.9 0 3.3 2.8 01/03/2006 18:00:00 5.1 0.7 7.2 3.4 5.2 0.7 6.8 3.4 4.7 0.7 7.2 2.6 58 10 80 165 2.6 0 2.8 2.6 01/03/2006 18:10:00 6.3 0.7 8 4.6 6.5 0.7 8.4 4.9 5.8 0.8 8 4.2 75 7 79 165 2.9 0.1 3 2.6 01/03/2006 18:20:00 5.6 0.6 7.2 4.2 5.8 0.6 7.6 4.2 5.3 0.6 6.8 3.8 73 7 84 165 3.1 0 3.3 3 01/03/2006 18:30:00 4.7 0.9 6.5 2.3 4.8 0.9 6.5 2.3 4.2 0.7 6.1 2.3 58 9 75 165 3 0.1 3.3 2.8 01/03/2006 18:40:00 4 0.6 6.1 2.3 4.1 0.6 6.1 2.3 3.6 0.7 5.3 1.9 57 7 57 165 2.9 0 3 2.8 01/03/2006 18:50:00 4.8 0.8 6.8 3.4 5 0.8 7.2 3 4.4 0.8 6.8 2.6 62 8 67 165 2.9 0 3 2.8 01/03/2006 19:00:00 5.3 0.8 7.2 3.4 5.5 0.8 7.6 3.4 5.1 0.6 7.2 3.8 65 7 58 165 3.1 0 3.3 3 01/03/2006 19:10:00 5.5 0.9 8 3.4 5.7 0.9 8 3.4 5.1 0.8 7.6 3 70 8 73 165 3.2 0 3.3 3 01/03/2006 19:20:00 6.1 0.8 8 4.2 6.3 0.8 8.4 4.2 5.7 0.8 7.6 3.4 68 9 69 165 3.3 0 3.5 3.3 01/03/2006 19:30:00 5.9 0.9 7.6 3.4 6 0.9 8 3.4 5.4 0.8 7.2 3.4 66 7 79 165 3.3 0 3.5 3.3 01/03/2006 19:40:00 6.3 0.7 8.4 4.2 6.5 0.7 8.8 4.2 5.8 0.7 7.6 3.8 68 6 75 165 3.3 0 3.5 3.3 01/03/2006 19:50:00 5.4 0.6 7.2 3.8 5.6 0.7 7.6 3.8 5.1 0.6 6.8 3.4 63 6 61 165 3.3 0 3.5 3.3 01/03/2006 20:00:00 5.1 0.5 6.1 4.2 5.3 0.5 6.5 4.2 4.8 0.5 6.1 3.4 59 6 50 165 3.3 0 3.5 3.3 01/03/2006 20:10:00 5.4 0.5 6.8 4.2 5.5 0.5 7.2 3.8 4.9 0.6 6.5 3 52 5 61 165 3.3 0 3.5 3.3 01/03/2006 20:20:00 5.3 0.5 6.5 4.2 5.4 0.5 6.8 4.2 5 0.5 6.5 3.4 55 6 45 165 3.3 0 3.5 3.3 01/03/2006 20:30:00 5.2 0.8 6.8 2.6 5.3 0.8 7.2 2.6 4.8 0.6 6.8 2.6 64 7 65 165 3.2 0 3.3 3.3 01/03/2006 20:40:00 5.6 0.8 7.6 3.4 5.8 0.8 7.6 3.4 5.3 0.7 7.2 3.8 65 7 74 165 3.3 0 3.5 3.3 01/03/2006 20:50:00 5.6 0.6 6.8 4.2 5.7 0.6 7.2 4.2 5.2 0.6 6.8 3.4 62 6 63 165 3.3 0 3.5 3.3 01/03/2006 21:00:00 5.2 0.6 6.8 3.8 5.4 0.6 6.8 3.4 5 0.6 6.5 3.4 61 6 68 165 3.3 0 3.5 3.3 01/03/2006 21:10:00 5.2 0.5 6.5 3 5.3 0.6 6.5 3.4 4.9 0.5 6.5 3.4 56 5 62 165 3.3 0 3.5 3.3 01/03/2006 21:20:00 4.4 0.6 5.7 3 4.4 0.6 6.1 3 4.1 0.6 5.7 3 59 7 48 165 3.3 0 3.5 3.3 01/03/2006 21:30:00 4.9 0.6 6.5 3.4 5.1 0.7 6.5 3.4 4.7 0.7 6.1 3.4 62 6 48 165 3.3 0 3.5 3.3 01/03/2006 21:40:00 5.3 0.5 6.5 3.8 5.4 0.6 6.8 4.2 5.1 0.5 6.8 3.4 63 7 54 165 3.3 0 3.5 3.3 01/03/2006 21:50:00 4.9 0.5 6.5 3.4 5 0.6 6.5 3.4 4.8 0.6 6.5 3.4 64 7 75 165 3.4 0 3.5 3.3 01/03/2006 22:00:00 5.3 0.5 6.5 3.4 5.4 0.6 6.8 3.4 5.1 0.6 6.5 3.8 58 6 68 165 3.3 0 3.5 3.3 01/03/2006 22:10:00 5.6 0.6 6.8 4.2 5.6 0.7 6.8 4.2 5.1 0.6 6.8 3.8 52 6 57 165 3.3 0 3.5 3.3 01/03/2006 22:20:00 5.6 0.7 7.2 3.8 5.6 0.7 7.2 3.8 5.1 0.7 6.8 3.4 51 7 48 165 3.4 0 3.5 3.3 01/03/2006 22:30:00 6.1 1.8 10.3 3 6.2 1.9 10.3 2.6 5.7 1.7 9.9 3 66 13 79 165 3.2 0.1 3.5 2.8 01/03/2006 22:40:00 7.3 1 9.5 4.9 7.5 1 9.5 4.9 6.7 1 9.1 3.8 76 8 78 165 2.6 0 2.8 2.6 01/03/2006 22:50:00 6.5 0.9 8.8 3.8 6.7 1 9.1 3.8 6.2 1 8.4 3.4 79 9 81 165 3.1 0 3.3 2.8 01/03/2006 23:00:00 5.1 0.5 6.5 3.8 5.3 0.5 6.8 4.2 4.8 0.5 6.1 3.4 45 7 50 165 2.8 0.2 3.3 2.6 01/03/2006 23:10:00 5.5 0.5 6.5 4.2 5.5 0.5 6.8 4.2 5.1 0.5 6.5 3.8 40 8 48 165 2.6 0 2.8 2.6 01/03/2006 23:20:00 5.2 0.5 6.5 4.2 5 0.6 6.5 3.8 5.2 0.5 6.5 4.2 25 5 29 165 2.6 0 2.8 2.6 01/03/2006 23:30:00 5.1 0.4 6.5 4.2 4.9 0.5 6.5 3.4 5.2 0.5 6.5 4.2 23 4 22 165 2.6 0 2.8 2.6 01/03/2006 23:40:00 5 0.4 6.1 3.8 4.9 0.5 6.1 3.8 5.1 0.4 6.1 3.8 25 5 28 165 2.6 0 2.8 2.6 01/03/2006 23:50:00 4.5 0.3 5.3 3.4 4.5 0.4 5.3 3.4 4.6 0.4 5.3 3.4 28 5 23 165 2.7 0 2.8 2.6 01/04/2006 00:00:00 4.1 0.4 4.9 2.6 4.1 0.5 5.3 1.9 4.3 0.4 5.3 3 28 6 28 165 2.8 0 2.8 2.8 01/04/2006 00:10:00 3.9 0.4 4.6 2.6 4 0.4 4.6 2.6 4 0.4 4.6 2.6 32 5 33 165 2.9 0 3 2.8 01/04/2006 00:20:00 3.7 0.4 4.6 2.6 3.7 0.4 4.9 2.6 3.6 0.5 4.6 2.3 42 8 33 165 3 0 3 2.8 01/04/2006 00:30:00 4.4 0.6 5.3 3 4.5 0.6 5.7 3.4 4.2 0.6 5.7 3 46 4 48 165 3 0 3 2.8 01/04/2006 00:40:00 4.2 0.4 4.9 3 4.3 0.4 5.3 3 4 0.4 5.3 3 45 4 48 165 3 0 3.3 3 01/04/2006 00:50:00 3.6 0.5 4.6 1.9 3.6 0.5 4.6 1.9 3.5 0.5 4.6 2.3 44 4 39 165 3.1 0 3.3 3 01/04/2006 01:00:00 3.7 0.6 5.7 2.3 3.8 0.6 6.1 2.3 3.5 0.6 4.6 2.3 49 7 63 165 3.1 0 3.3 3 01/04/2006 01:10:00 5.3 0.6 7.2 3.8 5.3 0.6 7.6 3.8 5 0.5 6.5 3.4 43 5 41 165 3.1 0 3.3 3 01/04/2006 01:20:00 5.2 0.4 6.1 4.2 5.3 0.4 6.5 4.2 5.2 0.5 6.5 3.8 38 4 43 165 3.1 0 3.3 3 01/04/2006 01:30:00 4.9 0.4 5.7 3.4 5 0.4 5.7 3.4 4.9 0.4 5.7 3.8 34 4 32 165 3 0 3.3 3 01/04/2006 01:40:00 4.6 0.4 5.3 3.4 4.6 0.4 5.3 3.4 4.6 0.4 5.7 3.4 37 4 39 165 3.2 0 3.3 3.3 01/04/2006 01:50:00 4.2 0.4 5.7 3.4 4.2 0.5 5.7 3.4 4.2 0.5 5.3 3 38 7 50 165 3.2 0 3.3 3 01/04/2006 02:00:00 4.1 0.5 5.3 2.6 4.1 0.5 5.3 2.6 4.2 0.5 5.3 3 34 6 47 165 3.2 0 3.3 3.3 01/04/2006 02:10:00 4.9 0.5 6.1 3.4 4.7 0.6 6.1 3 5 0.5 6.1 3.4 23 5 15 165 3.3 0 3.5 3.3 01/04/2006 02:20:00 4.9 0.4 6.1 3.8 4.8 0.5 6.5 3.4 4.8 0.4 5.7 3.8 26 5 28 165 3.3 0 3.5 3.3 01/04/2006 02:30:00 5.3 0.5 6.8 4.2 5.1 0.6 6.8 3.4 4.9 0.6 6.5 3.4 24 6 34 165 3.3 0 3.5 3.3 01/04/2006 02:40:00 5.6 0.6 6.8 4.2 5.5 0.7 6.8 3.4 5.4 0.7 6.8 3.4 24 6 28 165 3.2 0 3.5 3 01/04/2006 02:50:00 5.4 0.6 6.8 4.2 5.4 0.6 6.8 3.8 5.3 0.6 6.5 3.4 28 6 26 165 3.2 0 3.5 3.3 01/04/2006 03:00:00 5 0.5 6.1 3.8 4.9 0.5 6.1 3.8 4.9 0.5 6.1 3 32 5 37 165 3.2 0 3.3 3 01/04/2006 03:10:00 4.6 0.4 5.7 3.8 4.6 0.4 5.7 3.8 4.6 0.5 5.7 3 29 3 31 165 3.1 0 3.3 3 01/04/2006 03:20:00 5.1 0.6 6.8 3.4 5.1 0.6 6.8 3 5.1 0.6 6.8 3.4 27 5 26 165 3.2 0 3.3 3 01/04/2006 03:30:00 4.7 0.7 6.8 3 4.6 0.8 6.8 3 4.5 0.8 6.8 2.6 35 9 34 165 3.2 0 3.5 3 01/04/2006 03:40:00 4.6 0.8 6.8 2.6 4.6 0.8 6.5 2.6 4.5 0.8 6.5 3 36 11 27 165 3.2 0 3.3 3.3 01/04/2006 03:50:00 5.8 0.8 7.6 3.4 5.7 0.8 7.6 3.4 5.5 0.8 7.2 3.4 25 6 28 165 3.3 0 3.5 3.3 01/04/2006 04:00:00 5.8 0.7 7.6 3.8 5.6 0.8 7.6 3 5.5 0.7 7.2 3.8 25 7 21 165 3.3 0 3.5 3.3 01/04/2006 04:10:00 5.2 0.9 7.2 3.4 5.1 0.9 7.2 3 5 0.9 6.8 2.6 29 7 27 165 3.3 0 3.5 3.3 01/04/2006 04:20:00 4.8 0.6 6.1 3 4.7 0.6 6.1 3 4.7 0.7 6.1 3 37 8 36 165 3.3 0 3.5 3.3 01/04/2006 04:30:00 5.4 0.6 7.2 3.8 5.2 0.7 7.2 3.4 5.1 0.7 6.8 3.4 22 6 31 165 3.3 0 3.5 3.3 01/04/2006 04:40:00 4.9 1 8 3 4.9 1 8 3 4.8 1 7.6 2.6 44 14 54 165 3.3 0 3.5 3 01/04/2006 04:50:00 5.2 0.8 7.6 3.4 5.1 0.8 7.6 3.4 4.9 0.8 7.2 3.4 39 9 54 165 3 0 3.3 3 01/04/2006 05:00:00 4.9 0.4 5.7 3.8 4.9 0.4 5.7 3.8 4.8 0.4 6.1 3.8 27 3 28 165 3 0 3.3 3 01/04/2006 05:10:00 5.7 1.1 8 4.2 5.7 1.1 8 4.2 5.4 1.1 8 3.4 35 6 25 165 3 0 3.3 3 01/04/2006 05:20:00 6.7 0.7 8.4 5.3 6.8 0.7 8.4 4.9 6.7 0.7 8.4 4.9 32 5 37 165 3 0.1 3.3 2.8 01/04/2006 05:30:00 6 0.4 7.2 4.9 6 0.4 7.2 4.9 5.9 0.5 7.2 4.6 27 3 31 165 2.9 0 3 2.8 01/04/2006 05:40:00 5.9 0.9 8.4 3.8 5.9 1 8.4 3.8 5.7 1.1 8.4 3.4 30 5 30 165 3 0 3.3 2.8 01/04/2006 05:50:00 5.7 0.5 6.8 3.8 5.7 0.5 7.2 3.8 5.6 0.6 7.2 4.2 39 8 36 165 3.2 0 3.3 3.3 01/04/2006 06:00:00 5.3 0.7 6.8 3.4 5.3 0.7 6.8 3 5.1 0.7 6.8 3.4 41 14 18 165 3.3 0 3.5 3.3 01/04/2006 06:10:00 6.1 1 8.4 4.2 6 1 8.4 3.8 5.9 1.1 8.4 3.4 39 19 27 165 3.3 0 3.5 3.3 01/04/2006 06:20:00 6 0.8 7.6 3.8 5.5 1 7.6 2.3 6.1 0.8 8 4.2 19 6 22 165 3.2 0 3.5 3.3 01/04/2006 06:30:00 6.9 0.7 9.1 4.9 6.3 0.8 8.8 3.8 6.9 0.8 8.8 4.6 18 7 15 165 3.2 0 3.5 3 01/04/2006 06:40:00 7.6 0.8 9.5 5.7 6.7 1.1 9.1 4.2 7.5 0.9 10.3 4.9 15 7 17 165 3 0 3.3 3 01/04/2006 06:50:00 5.1 1.7 8 1.9 4.9 1.5 8 1.9 5 1.6 8.8 1.9 30 12 16 165 3 0 3.3 2.8 01/04/2006 07:00:00 5.9 0.9 8 3 5.9 0.9 7.6 3 5.9 1 8 3.4 32 9 37 165 2.8 0 3 2.6 01/04/2006 07:10:00 6.9 0.6 8.4 4.9 6.7 0.8 8.4 4.2 6.7 0.8 8.8 4.6 25 6 26 165 2.9 0 3 2.8 01/04/2006 07:20:00 6.1 1.1 8.4 3.4 5.8 1.1 8.8 3.4 5.8 1.1 8.4 3.4 24 10 26 165 2.9 0 3 2.8 01/04/2006 07:30:00 6.5 0.6 8 4.6 5.8 0.7 8 3.8 6.5 0.6 8.4 4.9 16 5 20 165 2.9 0 3 2.8 01/04/2006 07:40:00 6.8 0.5 8 4.6 6.5 0.6 7.6 4.6 6.7 0.7 8 4.6 21 4 18 165 2.7 0 2.8 2.6 01/04/2006 07:50:00 6.4 0.7 8.4 4.2 6.1 0.8 8 4.2 6.1 0.8 8 3.8 24 6 20 165 2.7 0 2.8 2.6 01/04/2006 08:00:00 6.3 0.5 7.6 4.9 6.3 0.5 7.6 4.9 6.3 0.6 7.6 4.9 26 4 19 165 2.7 0 2.8 2.6 01/04/2006 08:10:00 5.7 0.5 6.8 4.2 5.7 0.6 6.8 4.2 5.6 0.6 7.2 4.2 27 5 27 165 2.7 0 2.8 2.8 01/04/2006 08:20:00 5.3 0.9 7.2 3 5.2 1 7.2 2.3 5.2 0.9 7.2 3 27 7 34 165 2.9 0 2.8 2.8 01/04/2006 08:30:00 5.4 1 8.8 3.4 5.4 1 8.8 3.4 5.4 1 8.4 3.4 35 10 57 165 2.7 0.1 3 2.6 01/04/2006 08:40:00 6.4 0.8 8 4.6 6.4 0.8 8 4.2 6.1 0.8 8 3.8 45 6 49 165 2.3 0 2.6 2.3 01/04/2006 08:50:00 6.8 0.5 8 4.9 6.8 0.6 8 4.6 6.3 0.7 8 4.2 40 5 37 165 2.6 0 2.8 2.3 01/04/2006 09:00:00 6.1 0.6 7.2 3.8 6.2 0.6 7.2 4.2 5.7 0.7 7.2 3.4 43 6 39 165 2.9 0 3 2.8 01/04/2006 09:10:00 5 0.7 7.2 3 5.1 0.8 7.2 2.6 4.7 0.7 6.5 3 48 8 54 165 3 0 3.3 2.8 01/04/2006 09:20:00 5.4 0.7 7.2 3.8 5.5 0.7 7.6 3.4 5.1 0.7 6.5 3.4 49 7 56 165 3 0 3.3 3 01/04/2006 09:30:00 5.8 0.6 6.8 4.2 5.9 0.6 7.2 3.8 5.3 0.6 7.2 3.8 45 6 48 165 3.1 0 3.3 3 01/04/2006 09:40:00 5.6 0.6 7.2 3.8 5.7 0.7 7.2 3.8 5 0.8 6.8 3 49 7 50 165 3.2 0 3.3 3 01/04/2006 09:50:00 6.3 0.6 8 4.6 6.3 0.6 8.4 4.2 5.8 0.8 7.6 3.4 42 5 39 165 3.2 0 3.5 3.3 01/04/2006 10:00:00 7.1 0.7 8.8 5.3 7.1 0.7 8.8 4.9 6.7 0.7 8.4 4.9 41 4 36 165 3.2 0 3.3 3 01/04/2006 10:10:00 7.5 0.6 9.1 4.9 7.5 0.6 9.1 4.9 7.1 0.7 8.4 4.6 39 4 34 165 3.2 0 3.5 3.3 01/04/2006 10:20:00 7.7 0.6 9.1 5.7 7.7 0.6 9.1 5.7 7.2 0.8 8.8 4.9 37 4 40 165 3.3 0 3.5 3.3 01/04/2006 10:30:00 7.4 0.7 8.4 4.6 7.4 0.7 8.8 4.9 6.9 0.9 9.1 4.2 41 5 43 165 3.3 0 3.5 3.3 01/04/2006 10:40:00 7.5 0.6 8.8 5.7 7.4 0.6 8.8 5.3 7 0.7 9.1 4.2 36 4 37 165 3.4 0 3.5 3.3 01/04/2006 10:50:00 7.1 0.6 8.4 5.3 7.1 0.6 8.4 4.9 6.6 0.7 8 4.2 33 6 34 165 3.4 0 3.5 3.3 01/04/2006 11:00:00 7.4 0.8 9.5 4.6 7.4 0.9 9.9 4.6 6.9 1 8.8 4.2 35 7 40 165 3.4 0 3.5 3.3 01/04/2006 11:10:00 7.8 1 10.7 4.9 7.8 1 10.3 5.3 7.5 1 9.9 5.3 37 6 36 165 3.3 0 3.5 3.3 01/04/2006 11:20:00 7 0.7 8.8 4.9 7 0.8 8.8 4.9 6.9 0.8 8.8 4.6 31 6 32 165 3.1 0.1 3.5 3 01/04/2006 11:30:00 7.1 0.7 8.8 4.9 7 0.8 8.8 4.6 6.9 0.8 8.8 4.9 26 5 26 165 3.1 0 3.3 3 01/04/2006 11:40:00 6.5 0.8 8.4 4.6 6.4 0.8 8.4 4.2 6.4 0.8 8.8 4.6 27 6 19 165 3.2 0 3.3 3 01/04/2006 11:50:00 6.3 0.5 7.6 4.9 6.2 0.6 7.2 4.6 6 0.6 7.6 4.2 27 5 27 165 3 0 3.3 3 01/04/2006 12:00:00 6 0.7 7.6 4.2 5.9 0.8 7.6 3.8 5.8 0.8 8 3.8 26 6 19 165 3 0 3.3 3 01/04/2006 12:10:00 6.2 0.9 8.8 4.2 6.1 1 8.4 3.4 5.9 0.7 8 4.2 28 8 36 165 3.2 0 3.5 3 01/04/2006 12:20:00 6.9 0.8 8.8 3.8 6.8 0.8 8.4 3.4 6.7 0.8 8.4 4.2 33 6 31 165 3.2 0 3.5 3 01/04/2006 12:30:00 7.9 0.9 10.3 5.3 7.8 1 9.9 4.9 7.7 1 10.3 4.9 34 6 25 165 3 0 3.3 2.8 01/04/2006 12:40:00 7.5 0.6 8.8 5.3 7.5 0.7 9.1 4.9 7.2 0.8 9.1 4.9 35 5 34 165 3 0 3.3 2.8 01/04/2006 12:50:00 7.6 1 9.9 4.9 7.5 1 9.9 4.9 7.3 1.1 9.5 4.9 34 8 29 165 3.1 0 3.3 3 01/04/2006 13:00:00 7.1 0.9 9.1 4.6 6.8 1 9.1 4.2 6.9 1 9.5 4.6 23 7 20 165 3.2 0.1 3.5 3 01/04/2006 13:10:00 6.4 1 8.4 3.8 6.1 1 8.4 3.4 6.2 1 8.8 3.8 22 8 21 165 3 0 3.3 3 01/04/2006 13:20:00 4.6 1 7.6 2.6 4.5 1 8 2.6 4.5 1 7.6 2.6 52 17 32 165 3 0 3 2.8 01/04/2006 13:30:00 7.9 1.2 10.3 4.6 7.9 1.2 10.7 4.6 7.5 1.2 10.7 3.8 34 8 30 165 3.2 0.1 3.5 3 01/04/2006 13:40:00 8 1.1 10.3 4.9 7.9 1.1 10.7 4.9 7.7 1.2 10.3 4.6 33 7 36 165 3.5 0 3.5 3.3 01/04/2006 13:50:00 8.5 1.3 12.2 5.3 8.6 1.5 12.2 5.3 8.2 1.3 12.6 5.3 44 8 40 165 3 0.1 3.5 2.8 01/04/2006 14:00:00 8.3 1.1 11.5 5.7 8.2 1.1 11.1 5.3 7.9 1.2 11.1 5.3 39 8 22 165 3 0 3.3 2.8 01/04/2006 14:10:00 8.4 1.1 10.7 4.6 8.3 1.2 10.7 4.6 8.1 1.1 11.1 4.6 36 9 28 165 2.9 0 3.3 2.8 01/04/2006 14:20:00 7.9 1.2 11.1 4.9 7.9 1.2 10.7 4.9 7.6 1.2 11.1 4.9 35 7 37 165 2.9 0 3 2.8 01/04/2006 14:30:00 9.4 1.2 13 5.7 9.2 1.3 13 5.7 8.8 1.3 13 6.1 28 8 31 165 3 0 3.3 2.8 01/04/2006 14:40:00 8.8 1.2 11.5 5.3 8.6 1.3 11.5 5.3 8.4 1.2 11.1 5.3 28 8 37 165 3 0 3.3 2.8 01/04/2006 14:50:00 8.4 1.1 10.7 6.1 8.1 1.2 10.7 5.3 8.1 1 10.7 5.7 24 8 31 165 3 0 3.3 2.8 01/04/2006 15:00:00 9.2 1.4 12.6 6.5 9 1.5 12.6 6.1 8.8 1.4 12.6 6.1 26 8 10 165 3 0 3.3 3 01/04/2006 15:10:00 10.9 1.1 13.7 8 10.8 1.2 13.3 6.8 10.7 1.3 13.7 6.8 30 6 36 165 3 0 3.3 2.8 01/04/2006 15:20:00 9.9 1.2 13.7 7.2 9.8 1.3 13.3 6.5 9.6 1.3 13 6.1 27 7 28 165 2.9 0 3 2.8 01/04/2006 15:30:00 8.9 1.2 11.8 5.3 8.6 1.3 11.8 5.3 8.5 1.1 11.8 4.9 23 8 31 165 2.9 0 3 2.8 01/04/2006 15:40:00 9.7 1.2 12.6 6.1 9 1.5 12.6 5.3 9 1.3 11.8 4.9 17 8 18 165 2.9 0 3 2.8 01/04/2006 15:50:00 8.6 0.9 11.5 5.7 7.7 1.2 11.1 4.6 8.3 1 10.7 5.7 15 8 29 165 2.9 0 3 2.8 01/04/2006 16:00:00 7.8 1.2 10.7 4.9 7.4 1.3 10.3 3.8 7.5 1.2 11.1 4.2 21 9 29 165 2.9 0 3 2.8 01/04/2006 16:10:00 8.5 1.3 12.2 4.9 8.3 1.3 11.8 4.6 8.1 1.2 11.1 5.3 27 9 41 165 3 0 3 2.8 01/04/2006 16:20:00 9.1 1.3 12.2 6.1 8.8 1.4 12.2 5.7 8.6 1.3 12.2 5.7 26 9 37 165 3 0 3.3 3 01/04/2006 16:30:00 6.9 0.8 8.8 4.6 6.5 1 8.8 3.8 6.7 0.9 8.8 4.6 20 8 16 165 3 0 3.3 2.8 01/04/2006 16:40:00 8.3 1 10.7 5.7 7.7 1.1 10.7 4.9 7.9 1.1 10.7 4.9 20 9 18 165 3 0 3 2.8 01/04/2006 16:50:00 8.7 1.2 12.2 5.7 8.1 1.3 12.2 4.9 8.4 1.2 11.8 6.1 17 8 26 165 3 0 3 2.8 01/04/2006 17:00:00 8.4 1.1 10.7 5.7 7.9 1.2 10.7 4.6 8 1.1 10.3 5.3 20 8 16 165 3 0 3.3 3 01/04/2006 17:10:00 8.3 1 11.5 6.1 8.1 1.1 11.5 4.6 7.8 1 10.7 5.3 25 10 31 165 3.1 0 3.3 3 01/04/2006 17:20:00 10.3 2.1 15.6 5.7 10.2 2.1 15.6 5.7 9.8 2.2 15.3 4.9 31 10 37 165 3.5 0 3.5 3.3 01/04/2006 17:30:00 11.6 1.6 15.6 8 11.6 1.7 16.1 7.6 11.3 1.7 15.3 7.6 39 7 50 165 3.5 0 3.8 3.3 01/04/2006 17:40:00 11 1.9 16.8 7.2 10.9 2 17.2 6.5 10.5 1.9 14.9 6.5 32 9 28 165 3.4 0 3.5 3.3 01/04/2006 17:50:00 12 1.8 16.8 8 12.1 1.9 16.8 8 11.7 2 16.8 6.8 37 7 38 165 3.2 0 3.5 3.3 01/04/2006 18:00:00 11.1 1.5 14.9 6.5 11 1.5 14.9 7.2 10.8 1.5 15.3 7.6 32 8 43 165 3.2 0 3.3 3 01/04/2006 18:10:00 10.7 1.3 14.9 6.8 10.6 1.4 14.5 7.2 10.2 1.4 13.7 7.2 32 8 44 165 3.2 0 3.3 3 01/04/2006 18:20:00 12.1 1.6 15.6 7.6 12 1.7 15.6 6.8 11.6 1.8 16.1 6.8 30 9 18 165 3.3 0 3.5 3.3 01/04/2006 18:30:00 11.1 1.4 14.5 7.6 10.9 1.5 14.5 6.8 10.6 1.6 14.9 6.5 27 9 16 165 3.3 0 3.5 3.3 01/04/2006 18:40:00 12.8 1.5 16.4 8.8 12.6 1.7 16.4 8.4 12.2 1.9 16.1 7.2 26 9 34 165 3.2 0 3.5 3.3 01/04/2006 18:50:00 12.6 1.8 16.4 7.6 12.4 1.9 17.2 7.2 12 1.7 16.1 6.8 29 8 32 165 3.3 0 3.5 3.3 01/04/2006 19:00:00 12.6 1.7 17.2 8.4 12.5 1.7 17.6 7.6 12.2 1.7 17.2 8.4 31 8 28 165 3.3 0 3.5 3.3 01/04/2006 19:10:00 12 2 16.4 6.8 11.9 2 16.4 6.8 11.5 2 15.6 7.2 32 9 32 165 3.3 0 3.5 3.3 01/04/2006 19:20:00 12.8 2.1 17.6 7.2 12.7 2.2 17.2 6.5 12.5 2.2 17.2 6.5 32 9 26 165 3.5 0 3.5 3.3 01/04/2006 19:30:00 12.4 1.9 16.1 7.2 12.2 1.9 16.4 6.8 11.8 1.8 16.1 7.6 28 9 29 165 3.4 0 3.5 3.3 01/04/2006 19:40:00 12.9 1.7 16.4 8.8 12.8 1.7 16.4 8.8 12.5 1.7 16.4 8 31 8 29 165 3.4 0 3.5 3.3 01/04/2006 19:50:00 11.1 1.9 15.6 6.5 11 1.9 15.6 6.8 10.6 1.7 14.9 6.8 31 9 31 165 3.5 0 3.8 3.5 01/04/2006 20:00:00 12.3 1.5 16.4 8.8 12.2 1.6 16.1 7.6 11.8 1.6 16.1 6.5 29 8 29 165 3.5 0 3.5 3.5 01/04/2006 20:10:00 12.5 1.6 16.1 8 12.3 1.7 15.6 8 12 1.7 16.4 8 28 8 31 165 3.5 0 3.5 3.5 01/04/2006 20:20:00 12.6 1.7 16.8 8.4 12.3 1.8 16.8 7.2 12 1.5 15.3 7.2 26 8 33 165 3.5 0 3.5 3.5 01/04/2006 20:30:00 11.5 1.6 16.4 8 10.9 1.8 16.4 6.8 10.8 1.5 16.1 8 20 8 32 165 3.5 0 3.5 3.5 01/04/2006 20:40:00 10 1.6 16.1 6.5 9.7 1.7 16.4 6.1 9.5 1.7 15.6 5.7 24 9 29 165 3.5 0 3.5 3.3 01/04/2006 20:50:00 11.3 1.7 16.1 6.5 11.2 1.7 15.6 6.8 11 1.7 15.3 6.8 28 9 26 165 3.6 0 3.8 3.5 01/04/2006 21:00:00 11.8 1.9 16.4 7.2 11.6 1.9 16.1 6.8 11.2 1.8 16.4 7.6 31 8 30 165 3.8 0 3.8 3.5 01/04/2006 21:10:00 12.4 2.1 16.4 6.5 12.2 2.2 16.4 6.8 11.8 2.1 16.8 6.5 33 9 39 165 3.8 0 4 3.8 01/04/2006 21:20:00 12.7 2 17.6 6.8 12.6 2.1 17.6 6.1 12.3 2 18.3 7.6 34 9 34 165 3.9 0 4 3.8 01/04/2006 21:30:00 13.7 2.2 19.1 8.8 13.7 2.3 19.1 8.4 13.3 2.1 18.7 8.8 34 8 32 165 3.8 0 4.3 3.5 01/04/2006 21:40:00 13.1 1.5 16.8 9.1 13.1 1.6 16.8 8.8 12.8 1.7 16.4 8.4 39 6 34 165 3.8 0 4 3.5 01/04/2006 21:50:00 11.4 2.3 16.8 6.8 11.4 2.3 17.2 6.8 10.9 2.4 17.2 6.1 40 8 41 165 4 0 4.3 3.8 01/04/2006 22:00:00 11.6 1.6 16.8 7.6 11.6 1.7 16.8 7.2 11.1 1.7 16.8 6.8 37 8 36 165 3.9 0 4 3.8 01/04/2006 22:10:00 11.8 1.5 15.6 7.6 11.8 1.5 15.6 7.2 11.5 1.5 15.3 8 37 7 39 165 3.8 0 4 3.8 01/04/2006 22:20:00 8.9 1.4 13 4.9 9 1.5 13 4.9 8.6 1.3 13.3 5.7 46 8 39 165 3.8 0 4 3.8 01/04/2006 22:30:00 7.3 1.4 11.1 4.2 7.4 1.4 11.5 4.6 7 1.2 11.1 4.2 48 9 60 165 3.8 0 4 3.8 01/04/2006 22:40:00 7 1.3 9.9 4.2 7.1 1.3 9.9 4.2 6.7 1.3 9.9 3.8 59 12 46 165 3.8 0 4 3.8 01/04/2006 22:50:00 9.2 1.8 13.7 5.7 9.5 1.8 14.1 6.1 8.9 1.8 13.7 5.3 82 8 89 165 3.9 0 4 3.8 01/04/2006 23:00:00 11 0.9 13.3 8 11.3 1 13.7 8.4 10.6 1.1 13 8 89 6 83 165 3.6 0.1 3.8 3.3 01/04/2006 23:10:00 9.9 1.1 12.6 6.5 10.1 1.1 12.6 6.5 9.3 1.1 12.2 6.5 87 6 87 165 3.2 0.1 3.5 3 01/04/2006 23:20:00 9.5 1.1 13.3 6.1 9.7 1.1 13.7 6.5 8.9 1.1 11.8 5.7 80 7 84 165 3.5 0.1 3.8 3.3 01/04/2006 23:30:00 10.3 1 13 7.6 10.6 1.1 13.3 7.2 9.8 1.2 12.2 5.7 83 6 85 165 4.1 0.1 4.3 3.8 01/04/2006 23:40:00 10.7 1.3 13.7 7.2 11 1.3 14.1 7.6 10.2 1.2 13.3 6.8 83 7 102 165 4.3 0 4.5 4.3 01/04/2006 23:50:00 11.1 1.2 14.5 7.6 11.4 1.3 14.9 7.6 10.6 1.4 14.9 7.2 91 9 73 165 4.1 0.1 4.5 3.8 01/05/2006 00:00:00 9.4 0.9 11.5 6.5 9.7 1 12.2 6.8 8.8 1 11.5 6.1 96 7 107 165 3.7 0.1 4 3.5 01/05/2006 00:10:00 9.7 0.8 11.1 7.2 10 0.8 11.5 7.2 8.9 1 11.1 6.1 102 5 102 165 3.6 0 3.8 3.5 01/05/2006 00:20:00 9.7 0.8 11.8 6.8 9.9 0.8 12.2 6.8 9.1 1 11.5 5.7 96 6 100 165 3.7 0 3.8 3.5 01/05/2006 00:30:00 9.7 0.6 11.5 7.6 10 0.6 11.8 8 9.4 0.8 11.8 7.2 94 5 93 165 3.6 0 3.8 3.5 01/05/2006 00:40:00 9.2 0.7 11.1 6.8 9.5 0.8 11.5 7.2 8.7 1 11.5 6.5 97 6 98 165 3.8 0 4 3.5 01/05/2006 00:50:00 9 0.5 10.7 7.2 9.2 0.6 10.7 7.6 8.5 0.7 9.9 6.5 108 6 102 165 3.8 0 4 3.8 01/05/2006 01:00:00 7.8 0.7 9.1 5.7 8.1 0.7 9.5 6.1 7.5 1 9.5 4.6 107 9 116 165 3.8 0 4 3.8 01/05/2006 01:10:00 7 0.8 8.8 4.6 7.3 0.8 9.1 4.6 6.8 0.8 8.8 4.6 86 5 87 165 3.7 0.1 4 3.5 01/05/2006 01:20:00 7.6 0.5 8.8 6.1 7.9 0.5 9.1 5.7 7.2 0.6 8.4 4.6 92 5 90 165 3.6 0 3.8 3.5 01/05/2006 01:30:00 7.5 0.7 8.8 4.6 7.7 0.7 9.1 4.9 6.9 0.8 8.4 4.2 103 5 102 165 3.8 0 3.8 3.8 01/05/2006 01:40:00 7.8 0.8 9.1 5.3 8 0.7 9.5 5.7 7.2 0.9 9.1 4.9 101 5 93 165 3.6 0.1 3.8 3.5 01/05/2006 01:50:00 7.9 0.5 9.1 6.1 8.2 0.5 9.5 6.1 7.5 0.6 9.1 5.7 91 5 98 165 3.9 0 4.3 3.5 01/05/2006 02:00:00 6.3 0.9 8 3.8 6.6 0.9 8.4 4.2 5.9 0.9 8 3.8 76 7 85 165 3.9 0 4.3 3.8 01/05/2006 02:10:00 4.5 0.9 6.8 2.3 4.7 0.9 7.2 2.3 4.4 0.9 6.5 2.3 69 10 75 165 3.8 0 4 3.8 01/05/2006 02:20:00 5.8 1.2 8.4 3 6 1.2 8.8 3 5.6 1.1 8.4 3 75 8 84 165 3.8 0 4 3.8 01/05/2006 02:30:00 7 0.8 8.8 4.9 7.2 0.8 9.1 4.9 6.7 0.9 8.8 4.6 78 6 83 165 3.8 0 4 3.8 01/05/2006 02:40:00 6.6 0.7 8 4.2 6.8 0.7 8.4 4.6 6.3 0.7 8.4 4.2 75 5 77 165 3.8 0 4 3.5 01/05/2006 02:50:00 5.7 0.5 7.2 4.6 6 0.5 7.6 4.6 5.4 0.5 6.8 4.2 77 6 77 165 3.6 0 3.8 3.5 01/05/2006 03:00:00 6 0.5 6.8 4.6 6.3 0.5 7.6 4.9 5.6 0.5 6.8 4.2 86 6 86 165 3.7 0 3.8 3.5 01/05/2006 03:10:00 5.5 1 7.6 2.6 5.8 1.1 7.6 3 5.3 1 7.2 2.6 77 13 78 165 3.8 0 4 3.5 01/05/2006 03:20:00 4.5 0.7 5.7 2.6 4.7 0.7 6.1 3 4.3 0.6 5.7 2.6 72 10 80 165 3.5 0 3.8 3.3 01/05/2006 03:30:00 6.8 0.8 8 4.9 7.1 0.8 8.4 4.9 6.5 0.9 8 4.2 90 5 91 165 3.3 0 3.5 3.3 01/05/2006 03:40:00 6.8 0.4 7.6 5.7 7 0.4 8 5.7 6.5 0.5 7.6 4.9 88 5 93 165 3.4 0 3.5 3.3 01/05/2006 03:50:00 7.1 0.4 7.6 5.3 7.3 0.4 8 5.3 6.5 0.6 7.6 4.2 94 12 97 165 3.6 0 3.8 3.5 01/05/2006 04:00:00 6.2 0.6 7.2 4.2 6.4 0.6 7.6 4.6 5.8 0.6 6.8 4.2 73 6 73 165 3.3 0 3.8 3.3 01/05/2006 04:10:00 6.4 0.6 8 4.6 6.6 0.6 8 4.6 6 0.6 7.6 4.2 82 7 84 165 3.5 0.1 3.5 3.3 01/05/2006 04:20:00 6.4 0.6 7.6 4.9 6.6 0.6 8 4.9 6 0.6 7.6 4.6 84 5 88 165 3.6 0 3.8 3.5 01/05/2006 04:30:00 6.3 0.6 7.2 4.6 6.6 0.6 8 4.9 6.1 0.6 7.6 4.6 83 5 88 165 3.6 0 3.8 3.5 01/05/2006 04:40:00 4.5 1 6.5 2.6 4.7 1 6.8 2.6 4.2 1 6.5 1.9 67 9 76 165 3.5 0 3.8 3.3 01/05/2006 04:50:00 3 0.9 5.7 1.5 3.1 1 6.1 1.5 2.7 0.8 5.3 1.1 57 12 63 165 3.3 0 3.5 3.3 01/05/2006 05:00:00 3.7 0.7 6.1 1.9 3.9 0.8 6.1 1.9 3.4 0.6 4.9 1.9 66 8 68 165 3.5 0 3.5 3.3 01/05/2006 05:10:00 3.5 0.6 4.9 2.3 3.7 0.6 5.3 2.3 3.4 0.5 4.9 1.9 63 9 75 165 3.5 0 3.5 3.5 01/05/2006 05:20:00 3.7 0.6 5.7 1.9 3.8 0.6 5.7 2.3 3.3 0.5 4.9 2.3 56 7 43 165 3.6 0 3.5 3.5 01/05/2006 05:30:00 5 1 7.2 3.4 5 1 7.6 3 4.9 1 7.6 3 32 12 36 165 3.4 0 3.5 3.3 01/05/2006 05:40:00 5.4 0.7 8 4.2 5.5 0.8 7.6 4.2 5.5 0.8 8 3.8 28 5 37 165 2.9 0 3.5 2.6 01/05/2006 05:50:00 3.9 0.8 5.7 1.9 3.9 0.8 6.1 2.3 3.9 0.8 5.7 1.9 33 15 56 165 2.5 0.1 2.8 2.3 01/05/2006 06:00:00 4.2 0.6 6.1 3 4.3 0.6 6.1 3 3.9 0.5 5.7 2.3 48 11 68 165 2.6 0 2.8 2.3 01/05/2006 06:10:00 4.3 0.6 5.7 2.6 4.5 0.5 5.7 3 4.1 0.6 5.3 2.6 46 6 44 165 2.9 0 3 2.8 01/05/2006 06:20:00 4 0.4 4.9 3 4.2 0.4 5.3 3.4 4.1 0.4 4.9 3 32 4 42 165 3 0 3.3 2.8 01/05/2006 06:30:00 3.9 0.5 5.3 3 4 0.5 5.3 3 3.9 0.5 5.7 2.6 32 6 30 165 3 0 3.3 2.8 01/05/2006 06:40:00 4.4 0.4 5.3 3.4 4.4 0.4 5.7 3.4 4.4 0.4 5.3 3.4 30 8 37 165 3 0 3.3 2.8 01/05/2006 06:50:00 4.5 0.4 5.3 3.4 4.5 0.4 5.3 3 4.5 0.4 5.7 3.4 27 6 35 165 3 0 3.3 3 01/05/2006 07:00:00 4 0.4 4.9 3 4 0.4 4.9 3 3.9 0.4 4.6 2.6 31 6 31 165 3.1 0 3.3 3 01/05/2006 07:10:00 4 0.6 4.9 2.6 4.1 0.6 5.3 2.6 3.8 0.7 5.3 2.3 37 6 32 165 3.2 0 3.3 3 01/05/2006 07:20:00 4.6 0.3 5.3 3.8 4.7 0.3 5.3 3.8 4.7 0.3 5.3 3.8 31 3 33 165 3.2 0 3.3 3 01/05/2006 07:30:00 4.3 0.3 5.3 3.4 4.2 0.4 4.9 2.6 4.1 0.4 4.9 2.6 24 9 13 165 3 0 3.3 3 01/05/2006 07:40:00 4.9 0.6 6.5 3.4 4.6 0.8 6.5 2.3 4.5 0.6 5.7 3.4 20 8 27 165 3.1 0 3.3 3 01/05/2006 07:50:00 4.8 0.6 6.1 3 4.8 0.6 6.1 3 4.8 0.6 6.5 3 27 5 27 165 3 0 3.5 3 01/05/2006 08:00:00 4.6 0.4 5.7 3 4.6 0.5 5.7 3 4.6 0.5 5.7 3 24 5 25 165 3 0 3.3 3 01/05/2006 08:10:00 4.7 0.4 5.7 3.8 4.7 0.4 5.7 3.8 4.8 0.3 5.7 3.8 30 4 32 165 3 0 3.3 2.8 01/05/2006 08:20:00 4.6 0.5 5.7 3.8 4.1 0.5 5.3 3 4.7 0.4 5.7 3.8 18 3 14 165 2.9 0 3.3 2.8 01/05/2006 08:30:00 4.5 0.3 5.3 3.8 4.2 0.4 5.3 3.4 4.4 0.5 5.7 3.4 19 4 18 165 2.9 0 3 2.8 01/05/2006 08:40:00 4.6 0.6 6.1 3.4 3.9 0.7 5.7 1.9 4.5 0.6 6.1 3 16 7 19 165 3 0 3.3 2.8 01/05/2006 08:50:00 3.8 0.5 4.9 2.6 3.3 0.7 4.9 1.5 3.9 0.6 5.7 2.3 16 7 29 165 3 0 3.3 3 01/05/2006 09:00:00 4.7 0.5 6.1 3.8 4.2 0.7 6.1 1.9 4.7 0.5 6.1 3.8 18 7 12 165 3 0 3.3 3 01/05/2006 09:10:00 4.9 0.5 6.1 3.8 4.4 0.5 5.3 2.3 4.9 0.5 6.1 3.8 17 5 15 165 3 0 3.3 2.8 01/05/2006 09:20:00 5.1 0.3 5.7 4.6 4.9 0.4 5.7 3.8 5.3 0.3 6.1 4.2 22 5 19 165 2.9 0 3.3 2.8 01/05/2006 09:30:00 4.8 0.4 5.7 3.8 3.5 1 5.7 1.5 4.7 0.5 6.1 3.4 10 7 21 165 2.7 0.1 3 2.6 01/05/2006 09:40:00 4 0.3 4.6 3.4 3.1 0.8 4.9 1.1 4.2 0.3 4.9 3.4 352 4 358 165 2.4 0 2.8 2.3 01/05/2006 09:50:00 4.6 0.4 5.3 3.8 4.5 0.6 5.7 2.6 4.7 0.3 5.3 4.2 347 3 346 165 2.4 0 2.6 2.3 01/05/2006 10:00:00 4.5 0.4 5.7 3.8 4.4 0.6 5.7 2.3 4.6 0.4 5.7 3.8 343 6 344 165 2.4 0 2.6 2.3 01/05/2006 10:10:00 4.3 0.4 5.7 3.4 4.4 0.5 5.7 3 4.4 0.4 5.3 3 341 5 339 165 2.5 0 2.6 2.6 01/05/2006 10:20:00 4.6 0.4 5.7 3.4 4.6 0.4 5.7 3.8 4.6 0.4 5.7 3.8 341 4 334 165 2.5 0 2.8 2.6 01/05/2006 10:30:00 4.2 0.6 6.1 3 4.2 0.6 6.1 3 4.3 0.6 5.7 2.6 331 8 343 165 2.5 0 2.8 2.6 01/05/2006 10:40:00 4.3 0.4 5.3 3.4 4.4 0.4 5.7 3.4 4.5 0.5 5.7 3.8 338 5 334 165 2.5 0 2.8 2.6 01/05/2006 10:50:00 4 0.6 4.9 2.3 4 0.6 5.3 2.3 4.1 0.5 4.9 2.6 334 6 339 165 2.6 0 2.8 2.6 01/05/2006 11:00:00 4.3 0.6 6.1 2.6 4.3 0.5 5.7 2.6 4.4 0.5 5.7 3 323 11 315 165 2.6 0 3 2.6 01/05/2006 11:10:00 4.1 0.5 6.1 2.6 3.7 0.8 5.7 1.5 4.2 0.5 5.3 2.6 345 9 339 165 2.6 0 2.8 2.6 01/05/2006 11:20:00 4.7 0.7 6.1 3 3.8 0.8 6.1 1.5 4.9 0.7 6.5 3 352 9 0 165 2.7 0 2.8 2.6 01/05/2006 11:30:00 5.8 0.5 7.2 4.2 4.6 1.1 7.2 2.3 5.9 0.6 7.2 4.6 353 6 348 165 2.9 0 3 2.8 01/05/2006 11:40:00 5.7 0.4 6.5 4.6 4.5 1 6.8 2.3 5.7 0.4 6.8 4.9 353 5 348 165 2.9 0 3 2.8 01/05/2006 11:50:00 6.1 0.7 8.4 4.6 5.8 1.1 8.8 3 6.2 0.7 8.4 4.6 348 5 344 165 3.2 0 3.5 3 01/05/2006 12:00:00 5.8 0.7 7.6 3.8 5.7 0.7 7.6 4.2 5.7 0.7 7.6 4.2 335 8 338 165 3.2 0.1 3.5 3 01/05/2006 12:10:00 5.6 0.7 8 3.8 5.5 0.7 7.6 3.8 5.5 0.6 7.6 4.2 326 8 325 165 3.2 0 3.3 3 01/05/2006 12:20:00 6.2 1 8.8 4.2 6 1 9.1 3.8 6.2 0.9 8.8 4.6 340 10 344 165 3.6 0.1 3.8 3.3 01/05/2006 12:30:00 5.2 0.6 7.2 3.8 5.1 0.6 7.2 3.8 5.2 0.6 6.8 4.2 330 9 342 165 3.5 0 3.8 3.3 01/05/2006 12:40:00 4.8 0.5 6.5 3.4 4.8 0.5 6.5 3.4 4.8 0.5 6.5 3.4 324 9 330 165 3.2 0.1 3.5 3 01/05/2006 12:50:00 5.3 0.6 6.5 3.8 5.2 0.6 6.5 3 4.9 0.6 6.8 3.4 318 12 317 165 3 0 3.3 2.8 01/05/2006 13:00:00 4.9 0.8 6.5 2.3 4.9 0.8 6.5 3 4.1 0.6 6.1 2.3 306 12 300 165 3.1 0 3.3 3 01/05/2006 13:10:00 4.1 0.7 6.1 2.3 4.1 0.8 6.1 2.3 3.6 0.7 5.7 1.5 316 13 306 165 3.4 0 3.5 3.3 01/05/2006 13:20:00 4 0.8 5.7 1.1 3.9 0.8 6.1 1.1 4 0.7 5.3 2.3 331 13 329 165 3.2 0 3.5 3 01/05/2006 13:30:00 4.1 2.1 8 0.4 4 2.1 7.6 0.4 3.4 1.7 7.6 0.4 304 19 289 165 2.9 0 3.3 2.8 01/05/2006 13:40:00 5.9 0.7 8 3.4 5.9 0.7 7.6 3.4 5.1 0.8 7.6 3 300 10 295 165 2.7 0 2.8 2.6 01/05/2006 13:50:00 4.7 0.8 7.2 3 4.7 0.8 7.2 3.4 4.3 0.7 6.1 2.6 317 15 305 165 2.6 0 2.8 2.6 01/05/2006 14:00:00 5.4 0.9 7.6 3.4 5.4 0.9 7.6 3.4 4.9 1 7.6 2.6 294 10 289 165 2.7 0 2.8 2.6 01/05/2006 14:10:00 6.7 0.9 9.1 4.6 6.7 0.9 9.1 4.6 5.3 0.8 7.6 3.8 298 7 297 165 2.7 0 2.8 2.6 01/05/2006 14:20:00 7.6 0.8 9.1 5.3 7.6 0.8 9.1 5.7 6 0.9 8.8 3.8 296 7 297 165 2.7 0 2.8 2.6 01/05/2006 14:30:00 7.6 1 9.9 4.6 7.6 1 9.5 4.6 5.9 0.9 9.1 3.8 301 7 293 165 2.7 0 2.8 2.6 01/05/2006 14:40:00 7.8 0.8 9.5 4.9 7.9 0.8 9.9 5.3 6.5 1.1 9.9 4.2 297 8 307 165 2.5 0 2.8 2.3 01/05/2006 14:50:00 7.6 1.2 10.3 4.6 7.6 1.1 10.3 4.6 6.1 1.2 9.1 3 299 8 300 165 2.4 0 2.6 2.6 01/05/2006 15:00:00 8.5 1.7 11.5 4.2 8.5 1.6 11.5 4.2 6.9 1.3 9.9 3.8 302 8 295 165 2.4 0 2.6 2.3 01/05/2006 15:10:00 10 1.2 13 6.1 10 1.2 12.6 6.1 8 1.2 12.2 5.3 300 8 288 165 2.4 0 2.6 2.3 01/05/2006 15:20:00 10 1.2 13 6.8 9.9 1.2 12.6 6.5 7.9 1.1 11.5 4.9 300 7 298 165 2.4 0 2.6 2.3 01/05/2006 15:30:00 8.6 1.5 11.8 5.3 8.7 1.4 11.8 4.9 7 1.2 11.1 3.8 300 8 300 165 2.3 0 2.6 2.3 01/05/2006 15:40:00 8.4 1.5 11.8 4.9 8.5 1.5 11.8 5.3 7.1 1.6 11.1 3.8 294 8 290 165 2.3 0 2.3 2.3 01/05/2006 15:50:00 9.8 1.6 13.3 5.7 9.8 1.6 13 5.7 7.9 1.4 12.2 3.8 296 7 293 165 2.2 0 2.6 2.1 01/05/2006 16:00:00 10.6 1.2 15.6 8 10.6 1.2 15.6 7.6 8.1 1.3 13.3 5.7 299 7 287 165 2.1 0 2.3 2.1 01/05/2006 16:10:00 9.4 1.2 12.2 5.7 9.5 1.2 12.2 6.1 7.6 1.3 10.7 4.2 295 6 295 165 2.1 0 2.3 1.8 01/05/2006 16:20:00 9.6 1.4 12.2 5.3 9.6 1.5 12.6 5.3 8.1 1.7 11.8 3.4 290 6 287 165 2 0 2.3 1.8 01/05/2006 16:30:00 9.7 1.4 13.3 4.9 9.8 1.5 13.3 5.3 8.6 1.9 13 4.9 290 8 279 165 2 0 2.3 1.8 01/05/2006 16:40:00 10.3 1.6 14.5 5.7 10.4 1.6 14.1 5.7 8.6 1.9 13.7 4.6 294 7 293 165 2 0 2.3 1.8 01/05/2006 16:50:00 10.3 1.6 14.5 6.5 10.3 1.6 14.1 6.5 8.1 1.4 13 4.9 298 7 294 165 1.9 0 2.1 1.8 01/05/2006 17:00:00 9.7 1.2 13 6.5 9.7 1.2 12.6 6.8 7.8 1.3 11.5 5.3 296 6 293 165 1.9 0 2.1 1.8 01/05/2006 17:10:00 9.7 1.3 12.2 6.1 9.7 1.3 12.2 6.1 7.8 1.2 11.8 5.3 300 8 298 165 1.9 0 1.8 1.8 01/05/2006 17:20:00 8.4 1.1 11.1 5.7 8.4 1 10.7 5.3 6.6 1.1 9.5 3.8 299 7 291 165 1.9 0 1.8 1.8 01/05/2006 17:30:00 7.9 1.2 11.1 4.9 7.9 1.2 11.1 4.9 6.5 1.2 11.5 4.2 304 10 290 165 1.9 0 2.1 1.6 01/05/2006 17:40:00 6.7 1 8.8 4.2 6.7 1 9.1 4.2 6.2 0.9 8.4 3.8 312 8 290 165 1.6 0.1 1.8 1.4 01/05/2006 17:50:00 6.1 0.6 7.6 4.2 6.1 0.7 7.6 4.2 5.4 0.7 7.2 3.8 309 8 305 165 1.5 0.1 1.8 1.4 01/05/2006 18:00:00 6.2 0.8 8.4 4.6 6.2 0.8 8 4.6 5.1 0.8 7.2 3 305 10 299 165 1.4 0 1.6 1.4 01/05/2006 18:10:00 7.4 1 9.9 4.9 7.4 1 9.9 4.9 5.9 0.8 8.4 3.8 304 8 307 165 1.4 0 1.6 1.4 01/05/2006 18:20:00 7.5 0.8 9.5 5.3 7.5 0.8 9.1 5.3 5.8 0.8 8.4 3.8 300 6 300 165 1.4 0 1.6 1.4 01/05/2006 18:30:00 5.8 0.9 8.4 4.2 5.9 0.9 8 4.2 4.8 1 8 3 297 9 294 165 1.4 0 1.6 1.4 01/05/2006 18:40:00 5.8 0.6 7.2 4.2 5.8 0.6 7.2 4.2 4.7 0.7 6.5 3 306 6 309 165 1.3 0 1.6 1.4 01/05/2006 18:50:00 5.2 0.8 7.6 3.4 5.3 0.8 7.2 3.4 4.3 0.9 6.8 2.6 298 9 300 165 1.3 0 1.4 1.4 01/05/2006 19:00:00 5 0.6 6.1 3 5 0.6 6.5 3 4.1 0.8 6.8 2.3 306 12 292 165 1.2 0 1.6 1.1 01/05/2006 19:10:00 5 0.7 6.8 3 5 0.8 6.8 3 4.7 0.8 6.5 2.6 316 13 336 165 1.4 0 1.6 1.4 01/05/2006 19:20:00 5.2 0.8 7.2 3 4.7 0.7 7.2 3 5.2 0.9 7.2 3.4 333 17 359 165 1.4 0 1.6 1.4 01/05/2006 19:30:00 5.4 0.7 7.6 3 4.5 1 6.8 2.3 5.5 0.8 7.6 3 354 9 359 165 1.7 0 1.8 1.4 01/05/2006 19:40:00 4.4 0.8 6.5 2.3 3.9 0.8 6.1 1.9 4.7 0.7 6.5 3 343 13 353 165 1.3 0.1 1.8 1.1 01/05/2006 19:50:00 4.2 0.7 6.5 3 4.2 0.7 6.5 2.6 4.3 0.6 6.1 3 322 9 313 165 1.5 0 1.8 1.4 01/05/2006 20:00:00 5.1 0.6 6.8 3.4 5.1 0.6 6.5 3 4.7 0.7 6.5 3 314 11 319 165 1.4 0 1.6 1.1 01/05/2006 20:10:00 5 0.8 8.4 3.4 5 0.8 8.8 3.4 4.8 0.8 8 3 320 11 338 165 1 0 1.4 0.9 01/05/2006 20:20:00 4.8 0.9 7.2 2.3 4.8 1 7.2 1.9 4.1 0.8 6.8 1.9 311 12 330 165 1.3 0 1.6 0.9 01/05/2006 20:30:00 4.6 0.6 6.1 2.6 4.6 0.6 6.1 2.6 3.8 0.8 6.1 2.3 307 11 321 165 1 0 1.4 0.9 01/05/2006 20:40:00 4.7 0.6 6.1 3.4 4.7 0.6 6.5 3.4 4.3 0.6 6.1 2.6 308 10 281 165 1.1 0 1.4 0.9 01/05/2006 20:50:00 4 0.6 5.7 2.6 3.8 0.6 4.9 1.9 3.9 0.6 5.3 2.3 332 17 16 165 0.9 0 1.4 0.9 01/05/2006 21:00:00 3.1 0.6 4.6 1.1 2.5 0.8 4.6 0.7 3.3 0.6 6.1 1.5 355 11 16 165 1.4 0.1 1.6 1.1 01/05/2006 21:10:00 3.2 1 5.3 0.7 3 1.1 5.3 0.4 3.3 0.8 5.7 1.5 326 22 340 165 1.7 0.2 1.8 1.4 01/05/2006 21:20:00 3.2 0.7 5.3 1.1 3.3 0.7 5.3 1.5 3 0.8 4.9 0.4 301 22 300 165 1.8 0.1 2.3 1.6 01/05/2006 21:30:00 4.4 1 6.8 2.6 4.4 1 7.2 2.3 4.3 1.2 7.6 2.3 324 17 343 165 1.8 0 2.3 1.6 01/05/2006 21:40:00 4.2 1 6.8 1.1 4 1.1 7.2 1.1 4.2 1.1 6.8 1.5 334 15 326 165 1.9 0 2.1 1.8 01/05/2006 21:50:00 4.3 0.8 6.8 2.3 4 1 6.5 1.1 4.4 0.7 6.1 2.6 343 10 338 165 1.9 0 1.8 1.6 01/05/2006 22:00:00 3.5 1.2 7.6 1.5 3.2 1.2 7.6 1.1 3.5 1 6.5 1.5 331 17 348 165 1.8 0 1.8 1.6 01/05/2006 22:10:00 4 1.4 8 0.7 3.7 1.6 8 0.7 4 1.5 7.6 0.4 335 21 344 165 1.8 0 1.8 1.6 01/05/2006 22:20:00 2.9 1 6.1 0.7 2.7 1 5.7 0.4 3 1 6.1 0.7 332 18 356 165 2 0 2.3 1.8 01/05/2006 22:30:00 4.3 1.7 8.4 0.4 3.9 1.7 8.4 0.4 4.2 1.7 8.8 0.4 349 21 358 165 2 0 2.3 1.8 01/05/2006 22:40:00 5.9 1.2 9.5 3.4 5.4 1.4 9.5 2.3 5.5 1.2 8.8 3 343 15 337 165 1.8 0 2.3 1.6 01/05/2006 22:50:00 4.7 1.6 9.5 1.5 4.5 1.7 10.3 0.7 4.5 1.5 8.8 1.5 338 15 338 165 1.8 0 2.3 1.6 01/05/2006 23:00:00 3.6 1.2 6.8 1.1 3.2 1.2 6.5 0.4 3.7 1.4 7.6 0.7 348 22 12 165 2 0 2.3 1.8 01/05/2006 23:10:00 4.6 1.7 8.4 1.5 4.3 1.7 8.4 1.5 4.6 1.5 9.1 1.5 343 20 338 165 1.9 0 2.3 1.8 01/05/2006 23:20:00 5.8 1.7 10.3 2.6 5.5 1.9 10.3 2.3 5.7 1.9 11.5 2.3 335 16 340 165 1.7 0 1.8 1.4 01/05/2006 23:30:00 3.9 1.4 9.1 1.5 3.5 1.3 8 1.1 3.9 1.5 8.4 1.5 336 22 351 165 1.8 0 1.8 1.6 01/05/2006 23:40:00 5.7 1 8.4 3 5.2 1.3 8.4 2.3 5.5 1.1 8.8 2.3 344 13 350 165 1.5 0.1 1.8 1.4 01/05/2006 23:50:00 5.4 1.7 10.7 1.9 4.6 1.5 9.1 1.5 5.2 1.7 10.3 1.9 346 15 354 165 1.8 0.1 1.8 1.6 01/06/2006 00:00:00 4.4 1.1 8.8 1.9 4 1 8.8 1.5 4.2 1 8 2.3 331 28 7 165 1.8 0 1.8 1.6 01/06/2006 00:10:00 5.8 1.4 10.3 3 5.8 1.5 10.7 3 5.6 1.5 9.5 2.3 322 22 343 165 1.4 0.1 1.8 1.1 01/06/2006 00:20:00 4.8 1 7.6 2.3 4.8 1 7.6 2.3 4.5 0.8 7.2 3 314 17 273 165 1.2 0 1.6 0.9 01/06/2006 00:30:00 5.8 0.9 8 3 5.7 1 8 3 5.2 0.8 7.2 3 311 17 299 165 1.1 0 1.4 0.9 01/06/2006 00:40:00 6.3 1.1 9.1 3.4 6.2 1.1 9.5 3 5.6 1.2 9.5 2.6 309 18 359 165 1.1 0 1.4 0.9 01/06/2006 00:50:00 7.4 1.1 9.5 2.3 7.4 1.1 9.5 2.3 6.4 1.1 9.5 2.6 295 9 292 165 1.1 0 1.4 0.9 01/06/2006 01:00:00 7.5 0.9 9.5 5.3 7.5 0.8 9.5 5.3 6.4 1 9.1 3.8 297 9 298 165 1.3 0 1.4 1.4 01/06/2006 01:10:00 7.5 1.2 10.3 4.6 7.5 1.2 10.3 4.6 6.8 1.2 9.5 4.2 310 19 289 165 1.3 0.1 1.6 1.1 01/06/2006 01:20:00 6.7 1.2 9.5 3.8 6.7 1.2 9.5 3.8 6.5 1.2 9.5 3.4 323 13 335 165 1.5 0 1.6 1.4 01/06/2006 01:30:00 8 1.5 11.5 4.9 7.9 1.5 11.5 4.9 7.7 1.5 11.1 4.9 333 8 334 165 1.5 0 1.6 1.4 01/06/2006 01:40:00 7.4 1.2 10.3 4.9 7.4 1.2 10.7 4.9 7.3 1.1 9.9 5.3 332 8 336 165 1.7 0 1.8 1.6 01/06/2006 01:50:00 6.6 1 9.1 4.2 6.5 1.1 9.5 3.4 6.4 1.1 9.1 4.2 329 12 337 165 1.7 0 1.8 1.6 01/06/2006 02:00:00 6 0.9 8.8 3.4 5.6 1.1 9.5 3 5.9 1 8.8 3.8 339 13 348 165 1.8 0 1.8 1.6 01/06/2006 02:10:00 6.6 1 9.5 4.2 5.8 1.4 8.8 3 6.5 0.9 8.8 4.6 348 10 348 165 1.7 0 1.8 1.6 01/06/2006 02:20:00 8.5 1.2 11.5 4.6 8.1 1.5 11.8 3.4 8.5 1.1 11.5 5.7 346 7 348 165 1.7 0 1.8 1.6 01/06/2006 02:30:00 9 1 11.5 6.5 8.9 1.1 11.8 5.3 8.8 1 11.5 6.1 339 8 345 165 1.9 0.1 2.1 1.8 01/06/2006 02:40:00 8.5 0.9 11.5 6.1 8.4 1.1 11.5 5.3 8.4 0.9 11.5 6.5 342 7 341 165 1.8 0 2.1 1.6 01/06/2006 02:50:00 8.7 0.8 10.7 6.8 8.6 1.1 10.7 4.6 8.7 0.8 10.7 6.5 343 7 330 165 1.7 0 1.8 1.6 01/06/2006 03:00:00 8.1 0.8 11.8 5.7 7.9 1.1 10.7 3.8 8.1 0.9 11.8 6.1 340 9 350 165 1.4 0 1.6 1.4 01/06/2006 03:10:00 8.2 1 10.7 6.1 8.2 0.9 10.3 5.7 8.1 0.9 10.7 6.1 335 8 325 165 1.5 0 1.6 1.4 01/06/2006 03:20:00 9.2 1.1 12.2 5.7 9.2 1.1 12.6 5.7 9 1.2 12.2 5.7 335 7 344 165 1.6 0 1.8 1.4 01/06/2006 03:30:00 7.9 1.1 11.1 5.3 7.8 1.1 10.7 4.9 7.6 1.1 10.7 4.6 330 10 334 165 1.6 0 1.8 1.4 01/06/2006 03:40:00 7.3 0.9 9.5 5.7 7.2 0.8 9.1 5.7 7 0.8 9.1 5.3 330 7 331 165 1.5 0.1 1.8 1.4 01/06/2006 03:50:00 6.7 0.9 9.9 4.9 6.6 1 9.9 4.2 6.6 1 9.5 4.2 334 9 338 165 1.1 0 1.4 0.9 01/06/2006 04:00:00 6.3 1.2 9.5 3.4 6.2 1.2 9.1 3.4 6.2 1.1 9.5 3.8 338 9 335 165 1.2 0.1 1.4 0.9 01/06/2006 04:10:00 4.9 0.8 6.8 3.4 4.8 0.8 7.2 3.4 5 0.8 7.2 3.4 333 10 351 165 1.6 0 1.8 1.4 01/06/2006 04:20:00 5.1 1.1 8.8 2.3 4.9 1.2 9.1 2.3 5 1 8.4 2.6 341 9 349 165 1.8 0.1 1.8 1.6 01/06/2006 04:30:00 7 1.2 10.3 4.2 6.7 1.3 10.3 3.8 6.8 1.1 10.3 4.2 340 9 333 165 1.9 0 2.1 1.8 01/06/2006 04:40:00 6.4 0.8 8.4 3.8 6.2 1 8 2.3 6.1 0.7 8.4 4.6 340 9 338 165 1.9 0 2.1 1.8 01/06/2006 04:50:00 6.2 1.2 9.9 4.2 5.8 1.3 9.9 2.6 6 1.1 9.5 3.4 342 9 344 165 2 0 2.3 1.8 01/06/2006 05:00:00 6.3 1 9.1 4.2 5.7 1.3 8.4 1.9 5.9 0.9 8.8 3.8 340 13 345 165 1.9 0 2.3 1.8 01/06/2006 05:10:00 6.2 0.8 9.1 4.2 6 0.8 8.8 3.8 5.7 0.8 8 3.8 336 9 343 165 2 0 2.3 1.8 01/06/2006 05:20:00 6.1 1.1 9.1 3.4 6 1.2 9.1 3.4 5.7 1.2 9.5 2.6 330 13 322 165 2 0 2.3 1.8 01/06/2006 05:30:00 6.8 1 9.9 4.2 6.3 1.3 9.9 3.4 6.2 1.1 8.8 3.4 336 13 339 165 2 0 2.3 1.8 01/06/2006 05:40:00 5.8 1.2 9.5 3 5.6 1.3 9.1 2.6 5.2 1.4 8.8 2.3 326 17 324 165 2.2 0 2.3 2.1 01/06/2006 05:50:00 6.6 1.5 10.3 3 6.5 1.5 9.9 3 6.2 1.4 9.9 2.6 330 13 348 165 2.2 0 2.6 2.1 01/06/2006 06:00:00 8.8 1.4 11.8 5.3 8.6 1.6 12.6 4.6 8.3 1.4 11.8 4.9 339 9 339 165 2.3 0 2.6 2.3 01/06/2006 06:10:00 8 0.8 9.9 6.1 7.9 0.8 9.9 5.3 7.8 0.8 10.3 5.7 338 9 349 165 2.4 0 2.6 2.3 01/06/2006 06:20:00 8.2 0.8 10.3 5.7 8 1 10.7 4.6 7.8 0.8 9.9 4.6 340 10 339 165 2.4 0 2.8 2.3 01/06/2006 06:30:00 9.7 1 12.2 7.6 9.5 1.2 13 6.5 9.3 1 12.2 6.8 344 7 350 165 2.4 0 2.6 2.3 01/06/2006 06:40:00 8.3 0.8 9.9 6.1 7.8 1.3 10.7 3.8 7.9 0.9 10.7 5.3 347 7 340 165 2.3 0 2.6 2.3 01/06/2006 06:50:00 8.4 0.8 9.9 5.7 8.2 1 10.7 4.2 8 0.9 9.9 4.9 343 8 354 165 2.3 0 2.6 2.3 01/06/2006 07:00:00 9.1 1.2 12.2 6.5 9.2 1.3 13 6.1 9 1.2 12.6 6.1 344 6 341 165 2.4 0 2.6 2.3 01/06/2006 07:10:00 8 1.3 12.2 5.3 7.9 1.4 12.6 4.9 7.9 1.4 12.2 4.2 338 9 345 165 2.3 0 2.6 2.3 01/06/2006 07:20:00 7.9 0.9 9.9 5.7 7.6 1.1 10.3 4.2 7.8 0.9 9.9 5.7 343 9 356 165 2.3 0 2.3 2.3 01/06/2006 07:30:00 7.5 1.7 13.3 4.9 7.3 1.6 13 3.8 7.1 1.6 13.3 4.9 338 10 351 165 2.3 0 2.6 2.1 01/06/2006 07:40:00 9.1 1.6 13 6.5 9 1.7 13.7 5.3 8.6 1.7 13.7 5.7 333 11 318 165 2.1 0 2.3 2.1 01/06/2006 07:50:00 9.4 1.4 13.7 5.7 9 1.6 13.7 4.9 8.8 1.5 14.5 5.7 339 12 345 165 2 0 2.3 1.8 01/06/2006 08:00:00 9 1.2 13.3 6.1 8.7 1.2 13 5.7 8.6 1.1 11.5 6.1 334 9 337 165 1.8 0 2.1 1.6 01/06/2006 08:10:00 9.8 1.7 15.3 5.7 9.6 1.8 14.9 5.7 9.5 1.7 14.9 4.9 336 10 336 165 1.7 0 1.8 1.6 01/06/2006 08:20:00 10.4 1.1 13.3 7.2 10.2 1.3 14.1 6.5 9.7 1.1 12.6 6.5 337 9 338 165 1.7 0 1.8 1.6 01/06/2006 08:30:00 8.2 1.5 11.8 3.8 8 1.5 11.5 4.6 7.4 1.4 11.5 4.2 335 11 331 165 1.7 0 1.8 1.6 01/06/2006 08:40:00 8.3 1.5 12.2 4.9 8.1 1.6 12.2 4.2 7.7 1.7 11.5 4.2 335 13 330 165 1.5 0 1.8 1.4 01/06/2006 08:50:00 8.3 1.2 11.5 5.3 8.1 1.4 11.1 4.2 7.6 1.2 10.3 4.6 341 11 337 165 1.5 0 1.8 1.4 01/06/2006 09:00:00 7.9 1.5 11.5 5.3 7.5 1.5 11.5 4.2 7.1 1.2 10.3 4.6 339 13 334 165 1.4 0 1.6 1.4 01/06/2006 09:10:00 8.6 1.5 12.6 5.3 7.3 1.7 13.3 4.2 8.2 1.5 11.5 4.9 353 10 342 165 1.4 0 1.6 1.4 01/06/2006 09:20:00 9.7 1.7 14.5 6.8 9.3 2 14.9 4.6 9.4 1.9 14.9 5.3 346 10 346 165 1.4 0 1.6 1.4 01/06/2006 09:30:00 9.4 1.4 13 6.8 9.2 1.6 13.3 4.9 8.8 1.5 11.8 5.7 340 11 340 165 1.5 0 1.6 1.4 01/06/2006 09:40:00 8.7 1.2 11.5 6.1 8.3 1.3 11.8 5.3 8.1 1.2 12.6 5.3 335 13 325 165 1.4 0 1.6 1.4 01/06/2006 09:50:00 9.5 1.5 15.3 5.3 9.4 1.6 14.9 4.6 8.9 1.6 14.9 4.6 332 11 336 165 1.4 0 1.6 1.4 01/06/2006 10:00:00 10.5 1.8 15.6 7.2 10.3 1.9 16.1 6.5 10 1.9 16.1 6.5 337 13 329 165 1.5 0 1.6 1.4 01/06/2006 10:10:00 10.2 1.8 14.5 6.1 10 1.9 14.9 5.3 9.5 2 14.5 5.7 335 12 326 165 1.5 0.1 1.6 1.4 01/06/2006 10:20:00 9.6 1 12.6 6.8 9 1.3 12.2 5.7 9.4 1.1 13 6.8 345 11 8 165 1.4 0 1.6 1.4 01/06/2006 10:30:00 9.5 1.2 13 6.8 9 1.7 12.6 3.8 9.1 1.2 11.8 6.1 343 12 328 165 1.5 0 1.8 1.4 01/06/2006 10:40:00 10 1.6 15.3 6.8 9.6 1.9 14.1 4.9 9.7 1.7 14.9 6.5 342 12 0 165 1.7 0 1.8 1.6 01/06/2006 10:50:00 11.9 2.6 17.9 6.1 11.7 2.7 17.6 5.7 11 2.6 18.3 5.7 335 13 333 165 1.8 0.1 1.8 1.6 01/06/2006 11:00:00 12.7 1.7 17.9 8 12.6 1.8 17.9 8 12 1.9 18.7 7.6 330 11 336 165 1.9 0 2.1 1.8 01/06/2006 11:10:00 11.8 1.9 16.1 8 11.7 1.9 15.6 7.2 11.3 1.9 16.1 7.6 333 8 345 165 1.9 0 2.1 1.8 01/06/2006 11:20:00 11.4 1.5 16.8 7.6 11.3 1.6 16.8 7.2 10.7 1.8 16.8 6.1 335 11 337 165 1.8 0 2.1 1.6 01/06/2006 11:30:00 12.3 1.9 16.8 7.6 12.1 2.1 17.2 7.2 11.4 1.9 16.1 7.2 340 9 342 165 1.5 0 1.8 1.4 01/06/2006 11:40:00 14.9 2.3 20.2 8.8 14.9 2.3 21 8.8 14.5 2.4 20.2 8 336 10 336 165 1.4 0 1.6 1.4 01/06/2006 11:50:00 13.5 1.7 17.6 9.1 13.4 1.7 17.6 8.8 12.7 1.8 17.2 8 333 11 329 165 1.2 0 1.4 1.1 01/06/2006 12:00:00 14.6 1.9 18.7 9.1 14.4 2 18.3 9.1 14.1 2.1 17.9 9.5 339 9 353 165 1.2 0 1.4 0.9 01/06/2006 12:10:00 15.5 1.8 19.9 10.7 15.3 2 21 10.3 15 1.8 19.9 9.5 337 10 333 165 1.4 0 1.6 1.4 01/06/2006 12:20:00 14.6 1.8 19.5 9.9 14.6 1.9 19.5 9.5 13.7 2.1 19.5 8.4 333 9 332 165 1.4 0 1.6 1.4 01/06/2006 12:30:00 14.3 2 18.3 9.1 14.2 2 18.3 9.5 13.5 2 17.6 8 334 8 343 165 1.5 0 1.8 1.4 01/06/2006 12:40:00 14.2 2 20.2 8.8 14.2 1.9 19.9 8.8 13.3 2.2 19.5 7.6 332 11 334 165 1.5 0 1.8 1.4 01/06/2006 12:50:00 13.6 2.1 18.3 8.8 13.2 2.1 19.1 8.8 12.5 1.9 17.9 8.8 338 12 349 165 1.5 0 1.6 1.4 01/06/2006 13:00:00 14.1 1.5 17.9 9.9 13.9 1.7 17.6 8.4 13.5 1.6 17.6 8.4 341 9 342 165 1.5 0 1.6 1.4 01/06/2006 13:10:00 16.5 1.8 20.2 11.5 16.4 2 21 8 16.3 2 20.6 10.7 334 9 336 165 1.5 0 1.8 1.4 01/06/2006 13:20:00 16.3 1.7 21 11.5 16.1 1.7 21.4 9.9 15.9 1.9 20.6 10.7 336 8 335 165 1.8 0 1.8 1.6 01/06/2006 13:30:00 15.6 1.9 20.2 9.5 15.5 2.1 20.2 8.4 15.5 2 20.6 9.5 338 9 329 165 1.9 0 2.1 1.8 01/06/2006 13:40:00 16.3 1.6 23.3 12.2 16.2 1.7 23.7 9.9 15.7 1.7 20.6 10.3 338 8 354 165 1.9 0 2.3 1.8 01/06/2006 13:50:00 14.7 2 19.5 9.9 14.5 2.4 18.7 7.2 14.1 1.9 18.7 9.5 338 10 340 165 1.9 0 2.1 1.8 01/06/2006 14:00:00 13.9 2.2 19.9 9.1 13.8 2.2 20.2 8.8 13.4 2.1 20.2 8.8 333 9 338 165 1.9 0 2.1 1.8 01/06/2006 14:10:00 15.4 1.8 21.8 11.8 15.4 1.8 21.4 11.1 15.1 2.1 21.4 10.7 335 8 325 165 1.9 0 2.3 1.8 01/06/2006 14:20:00 15.2 1.9 19.9 9.9 15 2 20.2 9.5 14.9 2 19.1 8.8 336 9 338 165 1.9 0 2.1 1.8 01/06/2006 14:30:00 15.1 1.8 21.4 9.9 14.7 2 21.4 8.8 14.7 1.8 19.5 9.9 339 9 339 165 1.9 0 2.1 1.8 01/06/2006 14:40:00 14.9 1.9 19.9 9.9 14.8 2 19.9 10.3 14.7 2.1 19.1 9.9 334 8 344 165 1.9 0 2.1 1.8 01/06/2006 14:50:00 13.8 1.7 19.1 10.3 13.8 1.7 19.9 10.3 13.5 1.7 18.3 9.1 333 9 342 165 1.9 0 1.8 1.8 01/06/2006 15:00:00 12.8 2 17.6 8.8 12.7 2.2 17.6 8.4 12.7 2 17.9 8.4 337 9 344 165 1.8 0 1.8 1.8 01/06/2006 15:10:00 10.7 1.4 15.3 7.6 10.6 1.4 15.3 7.2 10.7 1.4 15.3 7.6 330 12 344 165 1.8 0 2.1 1.6 01/06/2006 15:20:00 9.4 1.2 13 6.8 9.3 1.2 12.6 6.5 9.3 1.1 12.2 6.5 325 10 343 165 1.7 0 1.8 1.6 01/06/2006 15:30:00 9.2 1.1 12.6 6.5 9.1 1.1 12.6 6.1 9 1.2 13 5.7 322 9 329 165 1.5 0.1 1.8 1.4 01/06/2006 15:40:00 9.2 1.3 12.2 5.3 9.1 1.2 11.8 5.3 8.8 1.1 11.8 6.1 320 10 330 165 1.4 0 1.6 1.4 01/06/2006 15:50:00 9 1.1 11.8 6.1 8.9 1.1 12.2 6.1 8.8 1 11.8 5.3 326 11 314 165 1.4 0 1.6 1.4 01/06/2006 16:00:00 9.4 1 11.5 6.5 9.3 0.9 11.5 6.5 9.1 1.2 11.8 5.7 319 9 327 165 1.4 0 1.6 1.4 01/06/2006 16:10:00 9.1 1.3 13.3 6.1 9 1.3 13 6.1 8.4 1.3 11.8 5.3 316 8 306 165 1.3 0 1.6 1.4 01/06/2006 16:20:00 9.3 1.5 12.6 4.9 9.2 1.5 12.6 5.3 8.4 1.5 12.2 4.9 315 9 314 165 1.3 0 1.6 1.4 01/06/2006 16:30:00 8.5 1.1 11.5 4.9 8.4 1.1 11.1 4.9 7.5 1.2 11.1 4.2 312 9 304 165 1.3 0 1.4 1.4 01/06/2006 16:40:00 8.1 1.2 10.7 4.9 8.1 1.2 11.1 4.9 7.7 1.2 10.7 4.9 320 10 337 165 1.5 0 1.8 1.4 01/06/2006 16:50:00 7.9 0.9 10.3 5.7 7.8 0.9 10.3 5.7 7.7 0.9 10.3 5.3 322 9 331 165 1.5 0.1 1.8 1.4 01/06/2006 17:00:00 8.3 1.1 11.1 4.2 8.2 1.1 10.7 4.2 8 1.1 11.1 4.9 322 9 329 165 1.5 0 1.8 1.4 01/06/2006 17:10:00 7.8 1.1 10.7 4.6 7.7 1.1 10.7 4.9 7.4 1.1 10.7 4.2 324 9 340 165 1.7 0 1.8 1.6 01/06/2006 17:20:00 7.6 0.9 10.3 5.7 7.5 1 10.3 4.6 7.4 0.9 9.9 4.9 331 9 341 165 1.8 0.1 1.8 1.6 01/06/2006 17:30:00 7.3 1 9.9 4.9 7.3 1 9.5 4.9 7 1 9.5 4.6 320 7 323 165 1.6 0.1 1.8 1.4 01/06/2006 17:40:00 7.6 0.9 10.7 4.9 7.5 0.8 9.9 5.7 7.4 0.9 10.3 5.3 320 9 322 165 1.2 0 1.4 1.1 01/06/2006 17:50:00 7.5 0.9 9.5 5.3 7.5 0.9 9.9 5.3 7.2 1.1 9.9 4.2 316 8 316 165 1.4 0.1 1.6 1.1 01/06/2006 18:00:00 8.7 0.7 10.3 6.5 8.7 0.6 10.7 6.8 8 0.9 9.5 5.3 313 5 316 165 1.4 0 1.6 1.4 01/06/2006 18:10:00 6.8 0.6 8.4 4.9 6.8 0.7 8.8 4.9 6.5 0.7 8.4 4.6 316 7 328 165 1.4 0 1.4 1.4 01/06/2006 18:20:00 6.4 0.6 8.4 4.6 6.4 0.6 8.4 4.9 6.3 0.8 8.4 4.2 317 8 321 165 1.6 0 1.8 1.4 01/06/2006 18:30:00 6.6 0.7 8.4 4.6 6.5 0.6 8 4.6 6.1 0.7 8 4.6 316 9 315 165 1.6 0 1.8 1.4 01/06/2006 18:40:00 6.4 0.7 8.4 4.2 6.4 0.7 8 4.6 6.4 0.8 9.1 3.4 327 11 315 165 1.7 0.1 1.8 1.4 01/06/2006 18:50:00 6.1 0.6 7.6 4.6 6.1 0.5 7.6 4.6 5.5 0.7 7.2 3.8 314 9 332 165 1.8 0 1.8 1.6 01/06/2006 19:00:00 5.4 0.6 6.8 4.2 5.5 0.5 6.8 4.2 4.9 0.6 7.2 3.4 311 8 302 165 1.6 0 1.8 1.4 01/06/2006 19:10:00 5.5 1 8 2.6 5.6 1 8 3 5.3 1.1 7.6 3 324 13 338 165 1.8 0.2 2.3 1.4 01/06/2006 19:20:00 5.2 0.8 6.8 3 5.2 0.8 6.8 3 5.2 0.8 7.2 3.4 331 10 336 165 2.3 0 2.3 2.1 01/06/2006 19:30:00 4.4 0.7 6.5 2.3 4.4 0.7 6.1 2.3 4.1 0.8 5.7 2.6 314 12 341 165 2 0.1 2.6 1.8 01/06/2006 19:40:00 5.7 0.6 7.2 3.8 5.7 0.6 7.6 3.8 5.8 0.8 8 3.4 321 8 323 165 1.9 0 2.1 1.8 01/06/2006 19:50:00 5.2 0.7 7.6 3.4 5.3 0.7 8 3.4 5.3 0.7 7.6 3 329 9 340 165 2 0 2.3 1.8 01/06/2006 20:00:00 5.1 0.5 6.8 3.8 5.1 0.5 6.8 3.4 5.1 0.5 6.5 3.8 325 9 313 165 1.9 0 2.1 1.8 01/06/2006 20:10:00 6.3 0.7 8 4.6 6.3 0.7 8 4.2 6.3 0.7 7.6 4.2 320 7 330 165 1.9 0 1.8 1.8 01/06/2006 20:20:00 6.2 0.8 8.8 4.6 6.3 0.8 8.4 4.6 6.1 0.8 8.4 4.2 320 9 319 165 2 0 2.1 1.8 01/06/2006 20:30:00 5.6 1 9.5 3.4 5.5 1.1 9.5 3 5.3 1 8.8 3.4 328 12 333 165 2.1 0.1 2.3 1.8 01/06/2006 20:40:00 5.4 1 8 3 5.4 1.1 8 2.3 5.4 1.1 8.4 2.6 337 9 349 165 2.3 0 2.6 2.3 01/06/2006 20:50:00 5.4 0.7 7.6 3.8 5.4 0.8 8 3 5.4 0.7 7.2 3.8 330 13 348 165 2.3 0 2.6 2.1 01/06/2006 21:00:00 5 0.7 6.8 3.4 5 0.7 6.8 3.4 5 0.7 6.8 3.4 324 11 331 165 2.1 0 2.3 1.8 01/06/2006 21:10:00 4.4 0.6 6.1 3 4.4 0.6 6.1 3 4.2 0.6 6.1 2.6 311 12 325 165 2.1 0 2.3 2.1 01/06/2006 21:20:00 5.3 0.7 7.6 3.4 5.3 0.7 7.6 3.4 5 0.8 7.6 2.6 319 17 338 165 1.9 0 2.3 1.8 01/06/2006 21:30:00 5.3 0.8 7.2 3.4 5.2 0.9 7.2 1.9 5.3 0.8 8 3.4 332 10 329 165 2.1 0 2.6 1.8 01/06/2006 21:40:00 6.3 1.5 9.5 3.8 6.3 1.5 9.5 3.4 6.3 1.3 9.1 3.4 337 10 344 165 2.3 0 2.6 2.1 01/06/2006 21:50:00 5.9 0.7 7.6 3.8 5.9 0.7 8 3.8 5.5 0.9 7.6 3 319 15 331 165 2.2 0 2.6 1.8 01/06/2006 22:00:00 7.1 0.8 9.1 4.9 7.1 0.9 9.5 4.9 6.3 1.3 9.5 3.8 309 11 319 165 1.8 0 2.1 1.6 01/06/2006 22:10:00 5.6 0.8 7.6 3 5.5 0.9 7.6 2.3 5.4 1 8 3 324 13 329 165 1.9 0 2.3 1.6 01/06/2006 22:20:00 5.4 0.7 6.8 3.8 5.4 0.7 7.2 3.4 5.5 0.6 7.2 4.2 338 11 349 165 2.1 0 2.3 1.8 01/06/2006 22:30:00 5.2 0.9 7.2 3 5.2 0.9 7.2 3.4 5.2 0.9 7.6 3 323 11 331 165 1.9 0 2.3 1.8 01/06/2006 22:40:00 5.4 0.7 7.2 3 5.4 0.8 7.2 3.4 5.3 0.7 7.2 3.4 329 11 338 165 1.7 0 1.8 1.6 01/06/2006 22:50:00 5.1 0.6 6.8 3.4 5.1 0.8 6.8 2.6 5.1 0.6 6.8 3.8 340 7 337 165 1.9 0 2.1 1.8 01/06/2006 23:00:00 4.5 0.7 6.5 3 4.4 0.9 6.5 2.3 4.6 0.6 6.1 3 338 9 331 165 1.9 0 2.1 1.8 01/06/2006 23:10:00 3.6 0.6 4.9 2.3 3.3 0.7 4.9 1.1 3.5 0.6 4.9 1.9 341 11 341 165 2.1 0 2.3 1.8 01/06/2006 23:20:00 3.3 0.4 4.2 2.3 2.9 0.6 4.2 1.1 3.4 0.4 4.6 2.3 340 16 351 165 2.4 0 2.6 2.3 01/06/2006 23:30:00 3.7 0.6 6.1 2.3 3.6 0.6 6.1 1.5 3.7 0.5 5.3 2.3 327 13 329 165 2 0 2.6 1.8 01/06/2006 23:40:00 3.4 0.4 4.6 1.9 3.1 0.7 4.6 1.1 3.3 0.4 4.2 1.1 339 12 349 165 1.8 0 2.1 1.8 01/06/2006 23:50:00 3.5 0.4 4.6 2.6 2.6 1 4.6 0.4 3.4 0.5 4.6 2.3 348 8 343 165 2 0 2.3 1.8 01/07/2006 00:00:00 2.6 0.7 4.2 1.1 1.7 0.9 3.8 0.4 2.6 0.8 4.2 1.1 355 8 352 165 2.3 0 2.6 2.3 01/07/2006 00:10:00 1.8 0.5 3 0.7 1.1 0.6 2.6 0.4 1.8 0.6 3 0.4 9 8 9 165 2.4 0 2.6 2.3 01/07/2006 00:20:00 2.1 0.3 2.6 1.1 1.3 0.5 2.6 0.4 2.2 0.3 2.6 1.5 6 6 3 165 2.4 0 2.6 2.3 01/07/2006 00:30:00 2.2 0.4 3.8 1.5 1.6 0.7 3.8 0.4 2.2 0.3 3.4 1.5 349 7 344 165 2.4 0 2.8 2.3 01/07/2006 00:40:00 3.1 0.8 5.3 1.5 2.7 0.7 4.6 1.1 3.1 0.7 4.6 1.9 343 12 1 165 2 0 2.3 1.8 01/07/2006 00:50:00 4.2 1 6.8 2.6 2.9 1.2 6.1 1.1 4 1.1 6.8 2.6 3 8 7 165 2.1 0 2.3 1.8 01/07/2006 01:00:00 4.4 0.9 6.1 2.3 3 1 5.3 1.1 4.4 0.8 6.1 2.3 4 10 13 165 2.1 0 2.3 1.8 01/07/2006 01:10:00 3.9 0.8 5.3 1.9 2.9 1.2 4.9 0.4 3.9 0.8 5.7 1.9 4 9 14 165 2 0 2.3 1.8 01/07/2006 01:20:00 4.7 0.4 5.7 3.4 3.6 0.7 4.9 1.5 4.7 0.4 5.7 3.8 10 5 7 165 2 0 2.3 1.8 01/07/2006 01:30:00 3.9 0.4 5.3 2.6 3.1 0.8 4.6 1.5 3.9 0.4 4.9 3 11 5 10 165 2.2 0 2.3 2.1 01/07/2006 01:40:00 4.6 0.4 5.7 3.8 3.4 0.8 5.3 1.9 4.4 0.4 5.7 3.4 10 5 18 165 2.3 0 2.6 2.3 01/07/2006 01:50:00 4.7 0.4 5.7 3 4.1 0.6 5.3 1.9 4.6 0.5 5.7 3.4 13 5 16 165 2.3 0 2.6 2.3 01/07/2006 02:00:00 4.7 0.5 6.1 3.4 4.2 0.7 5.7 1.9 4.7 0.4 5.7 3.8 16 6 18 165 2.4 0 2.6 2.3 01/07/2006 02:10:00 4.8 0.6 6.1 3.4 4.5 0.7 6.1 1.9 4.7 0.6 6.5 3.4 18 5 25 165 2.6 0 2.8 2.6 01/07/2006 02:20:00 4.7 0.4 6.1 3.8 4.2 0.5 5.7 2.6 4.7 0.4 5.7 3.4 16 5 17 165 2.5 0 2.8 2.6 01/07/2006 02:30:00 4.2 0.4 5.3 3.4 3.5 0.6 4.9 1.9 4.1 0.4 5.3 3 14 5 18 165 2.4 0 2.6 2.3 01/07/2006 02:40:00 5.5 0.8 7.2 3 4.4 1.2 6.8 1.9 5.4 0.9 7.2 3 11 6 21 165 2.5 0 2.6 2.6 01/07/2006 02:50:00 4.4 1 6.8 2.6 4 1.2 6.5 1.1 4.4 1 6.8 2.6 18 9 29 165 2.6 0 2.8 2.6 01/07/2006 03:00:00 4.8 1 6.8 3.4 3.4 1.3 6.5 1.1 4.7 0.9 7.2 3 7 6 18 165 2.6 0.1 2.8 2.6 01/07/2006 03:10:00 2.7 0.7 5.3 0.7 1.9 0.9 4.9 0.4 2.7 0.7 4.6 0.7 7 13 23 165 2.5 0 2.8 2.6 01/07/2006 03:20:00 1.8 1 6.1 0.4 1.5 1.1 5.7 0.4 1.4 0.8 4.6 0.4 23 20 52 165 2.7 0 2.8 2.6 01/07/2006 03:30:00 2.4 0.7 3.8 0.7 2.1 0.8 3.8 0.7 2.3 0.8 3.8 0.4 24 9 18 165 2.7 0 2.8 2.6 01/07/2006 03:40:00 3.2 1 7.6 1.9 3 1.1 8 0.7 3 1 7.2 1.1 25 11 33 165 2.8 0 2.8 2.6 01/07/2006 03:50:00 3.6 1.1 7.2 1.5 3.4 1.2 6.8 1.1 3.5 1.1 6.8 1.5 30 10 25 165 2.9 0 3 2.8 01/07/2006 04:00:00 3.3 1 6.1 1.1 3.2 1 5.7 0.7 3.1 1 6.1 0.7 34 15 13 165 3 0 3 2.8 01/07/2006 04:10:00 5.9 0.7 7.2 3.8 4.6 0.9 6.8 2.3 5.9 0.8 7.6 3.8 10 5 5 165 2.6 0.2 3.3 2.3 01/07/2006 04:20:00 5.4 0.4 6.1 4.2 4.7 0.4 5.7 3.8 5.3 0.4 6.1 4.2 14 2 14 165 2 0.1 2.3 1.8 01/07/2006 04:30:00 5 0.5 6.1 3.4 4.3 0.7 6.1 2.3 4.9 0.4 5.7 3.4 16 5 18 165 2.1 0 2.3 1.8 01/07/2006 04:40:00 4.6 0.5 6.5 3.4 4 0.6 5.3 1.5 4.4 0.5 6.1 2.6 17 7 19 165 2.4 0 2.6 2.3 01/07/2006 04:50:00 4.4 0.7 6.1 2.6 3.7 0.9 5.7 1.1 4.4 0.6 5.7 2.6 13 6 12 165 2.6 0 2.8 2.6 01/07/2006 05:00:00 4.1 0.4 5.3 3 3.4 0.8 4.9 1.1 4.3 0.4 5.7 3 15 8 10 165 2.8 0 3 2.8 01/07/2006 05:10:00 4.8 0.6 6.5 3.4 4.6 0.7 6.5 2.3 4.7 0.6 6.5 3 22 6 25 165 2.9 0 3 2.8 01/07/2006 05:20:00 3.6 0.6 4.9 2.3 3.3 0.6 4.6 1.5 3.7 0.6 4.9 1.9 26 12 10 165 2.9 0 3 2.8 01/07/2006 05:30:00 3.9 0.5 5.3 2.6 3.7 0.6 5.3 2.3 4.1 0.6 5.7 2.6 24 9 19 165 2.9 0 3 2.8 01/07/2006 05:40:00 3.9 0.8 6.8 1.5 3.9 0.8 6.5 1.5 3.9 0.8 6.5 1.9 40 15 88 165 3 0 3 2.8 01/07/2006 05:50:00 3.1 0.5 4.6 1.9 3.1 0.6 4.2 1.5 3.1 0.4 4.2 2.3 40 8 34 165 2.9 0 3 2.8 01/07/2006 06:00:00 3.5 0.4 4.6 2.6 3.5 0.4 4.6 2.6 3.6 0.4 4.6 2.6 40 6 37 165 2.9 0 3 2.8 01/07/2006 06:10:00 3 0.4 4.2 1.5 2.9 0.4 4.2 1.5 3 0.4 4.2 1.9 38 8 31 165 2.9 0 3 2.8 01/07/2006 06:20:00 3.4 0.4 4.6 2.3 3.3 0.4 4.6 2.3 3.3 0.4 4.9 2.3 31 8 28 165 2.8 0 3 2.6 01/07/2006 06:30:00 3 0.5 4.2 1.5 2.9 0.5 4.2 1.5 3.1 0.4 4.2 1.9 35 5 26 165 2.5 0 2.6 2.3 01/07/2006 06:40:00 2.9 0.4 3.8 1.9 2.7 0.4 3.8 1.9 3 0.3 3.8 2.3 29 7 34 165 2.5 0 2.8 2.6 01/07/2006 06:50:00 2.9 0.2 3.4 2.3 2.6 0.3 3.4 1.9 3 0.2 3.4 2.3 23 2 23 165 2.4 0 2.6 2.3 01/07/2006 07:00:00 2.5 0.2 3 1.9 2.3 0.3 3 1.5 2.5 0.2 3 1.9 26 5 29 165 2.4 0 2.6 2.3 01/07/2006 07:10:00 1.7 0.5 2.6 0.7 1.2 0.7 2.3 0.4 1.8 0.5 2.6 1.1 27 3 26 165 2.5 0 2.8 2.6 01/07/2006 07:20:00 1.1 0.2 1.5 0.7 0.6 0.3 1.5 0.4 1.3 0.2 1.9 0.7 29 5 21 165 2.5 0 2.8 2.6 01/07/2006 07:30:00 1.9 0.2 2.3 1.5 1.1 0.4 1.9 0.4 1.9 0.2 2.3 1.5 14 5 21 165 2.5 0 2.8 2.6 01/07/2006 07:40:00 2.1 0.2 2.6 1.5 1.5 0.3 2.3 1.1 2.1 0.2 2.6 1.5 13 0 13 165 2.5 0 2.6 2.6 01/07/2006 07:50:00 2.5 0.3 3 1.9 1.9 0.3 2.6 1.1 2.4 0.2 3 1.9 14 2 15 165 2.5 0 2.8 2.6 01/07/2006 08:00:00 2.5 0.4 3.4 1.5 2 0.5 3 0.7 2.5 0.3 3.4 1.9 15 3 18 165 2.5 0 2.8 2.6 01/07/2006 08:10:00 3.2 0.4 4.2 2.3 3.1 0.5 3.8 2.3 3 0.5 3.8 1.9 25 2 25 165 2.6 0 2.8 2.6 01/07/2006 08:20:00 3.4 0.5 4.6 2.3 3.3 0.5 4.2 1.9 3.2 0.5 4.2 1.9 23 3 22 165 2.5 0 2.8 2.3 01/07/2006 08:30:00 3 0.3 3.8 2.3 2.8 0.4 3.8 1.9 2.7 0.3 3.8 1.9 23 4 25 165 2.4 0 2.6 2.3 01/07/2006 08:40:00 2.1 0.4 3 1.5 1.6 0.5 2.6 0.4 1.9 0.4 2.6 1.1 17 2 20 165 2.4 0 2.6 2.3 01/07/2006 08:50:00 1.9 0.4 2.6 1.1 0.8 0.4 1.9 0.4 1.8 0.3 2.3 1.1 354 6 357 165 2.3 0 2.6 2.3 01/07/2006 09:00:00 1.8 0.4 2.6 1.1 0.6 0.4 1.9 0.4 1.7 0.4 2.3 0.7 353 2 350 165 2.3 0 2.6 2.3 01/07/2006 09:10:00 0.6 0.4 1.5 0.4 0.4 0 0.7 0.4 0.6 0.4 1.9 0.4 352 0 353 165 2.4 0 2.6 2.3 01/07/2006 09:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 352 0 165 165 2.4 0 2.6 2.6 01/07/2006 09:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 41 165 165 2.4 0 2.6 2.6 01/07/2006 09:40:00 2.1 1 3.4 0.4 2 1 3.4 0.4 2 1.2 3.8 0.4 43 15 36 165 2.4 0 2.6 2.3 01/07/2006 09:50:00 2.9 0.2 3.4 2.3 2.8 0.3 3.4 1.9 2.8 0.2 3.8 2.3 30 8 42 165 2.2 0 2.6 2.1 01/07/2006 10:00:00 3.3 0.3 3.8 2.6 3.1 0.3 3.8 2.3 3.1 0.3 3.8 2.3 26 6 16 165 2.1 0 2.3 1.8 01/07/2006 10:10:00 2.8 0.8 4.6 0.7 2.3 1.1 4.2 0.4 2.6 0.8 4.2 0.7 14 11 29 165 2 0 2.3 1.8 01/07/2006 10:20:00 2.9 0.3 3.4 2.3 1.6 0.5 3 0.4 2.8 0.3 3.8 1.9 358 8 12 165 1.9 0 2.1 1.8 01/07/2006 10:30:00 2.9 0.3 3.8 1.9 2 0.8 3.4 0.4 2.7 0.3 3.4 1.9 350 6 349 165 1.9 0 2.1 1.8 01/07/2006 10:40:00 3.1 0.2 3.8 2.6 1.5 0.6 3.4 0.4 3.1 0.2 3.8 2.6 355 4 351 165 1.9 0 1.8 1.8 01/07/2006 10:50:00 2.9 0.3 3.4 1.9 1.5 0.6 3 0.4 2.9 0.4 3.8 1.9 4 8 0 165 2 0 2.3 1.8 01/07/2006 11:00:00 3 0.3 3.8 2.3 2.5 0.5 3.4 1.1 3 0.4 3.8 1.9 16 5 16 165 2.1 0 2.3 2.1 01/07/2006 11:10:00 3.7 0.4 4.6 2.3 3.4 0.4 4.2 2.3 3.6 0.4 4.6 2.3 20 4 16 165 2.1 0 2.3 2.1 01/07/2006 11:20:00 3.5 0.5 4.9 2.6 3.1 0.4 4.6 2.3 3.5 0.5 4.6 2.3 19 5 19 165 2.1 0 2.3 2.1 01/07/2006 11:30:00 2.3 0.5 3 1.5 2.1 0.5 3 1.1 2.4 0.5 3.4 1.5 25 3 23 165 2.3 0 2.6 2.1 01/07/2006 11:40:00 1.4 0.3 2.3 0.7 1.2 0.3 1.9 0.7 1.5 0.3 2.3 0.7 37 4 29 165 2.4 0 2.6 2.3 01/07/2006 11:50:00 1.4 0.4 2.3 0.4 1.2 0.4 1.9 0.4 1.3 0.5 2.3 0.4 36 6 29 165 2.6 0 2.8 2.6 01/07/2006 12:00:00 1.9 0.3 3 1.1 1.7 0.3 3 1.1 1.8 0.3 2.6 1.1 35 6 38 165 2.6 0 2.8 2.6 01/07/2006 12:10:00 2.3 0.4 3 1.1 2.2 0.4 3.4 1.1 2.1 0.4 3 1.1 42 5 35 165 2.5 0 2.8 2.6 01/07/2006 12:20:00 2.1 0.4 3 1.1 2 0.5 3.4 1.1 1.9 0.4 3 1.1 52 8 52 165 2.5 0 2.6 2.6 01/07/2006 12:30:00 2.7 0.4 3.4 1.1 2.7 0.5 3.4 1.1 2.6 0.4 3.4 1.5 47 5 44 165 2.4 0 2.6 2.3 01/07/2006 12:40:00 3.1 0.3 3.8 2.3 3.1 0.3 3.8 2.3 3 0.3 3.8 2.3 40 5 43 165 2.3 0 2.6 2.3 01/07/2006 12:50:00 3.2 0.5 4.6 1.9 3.1 0.5 4.6 1.9 3.1 0.5 4.2 1.9 37 7 35 165 2.3 0 2.6 2.3 01/07/2006 13:00:00 4.3 0.5 4.9 3.4 4.3 0.5 5.3 3 4.3 0.5 5.3 3 32 6 25 165 2.2 0 2.6 2.1 01/07/2006 13:10:00 4.4 0.3 5.3 3.4 4.4 0.3 5.3 3.4 4.4 0.3 5.3 3.4 34 4 33 165 2.1 0 2.3 1.8 01/07/2006 13:20:00 4.3 0.3 4.9 3 4.2 0.4 5.3 2.6 4.3 0.5 5.3 2.6 34 5 29 165 2 0 2.3 1.8 01/07/2006 13:30:00 3.7 0.5 4.9 2.6 3.6 0.5 4.9 2.3 3.6 0.6 5.3 2.3 38 8 31 165 2 0 2.3 1.8 01/07/2006 13:40:00 3.8 0.5 5.7 2.6 3.7 0.6 5.7 1.9 3.8 0.6 5.7 2.6 31 10 48 165 2 0 2.3 1.8 01/07/2006 13:50:00 4.1 0.5 5.3 3 3.8 0.5 4.9 2.6 4.2 0.6 5.3 2.3 23 7 23 165 2.1 0 2.3 1.8 01/07/2006 14:00:00 4.2 0.5 5.3 2.6 3.9 0.6 4.9 1.9 4.1 0.5 5.3 3 22 5 22 165 2.1 0 2.3 2.1 01/07/2006 14:10:00 4.2 0.4 5.3 3 4 0.5 5.3 2.6 4.3 0.4 5.3 3 26 5 31 165 2.1 0 2.3 2.1 01/07/2006 14:20:00 3.5 0.6 4.6 2.3 3.3 0.6 4.6 1.5 3.6 0.6 4.9 2.3 25 8 29 165 2.1 0 2.3 1.8 01/07/2006 14:30:00 4 0.4 4.9 3.4 3.9 0.4 4.9 2.6 4.1 0.4 5.3 3 27 5 33 165 2.1 0 2.3 2.1 01/07/2006 14:40:00 4.7 0.5 6.1 3 4.7 0.6 5.7 2.6 4.8 0.5 6.1 3.4 29 6 33 165 2.1 0 2.3 2.1 01/07/2006 14:50:00 4.8 0.5 6.1 3.8 4.8 0.5 6.1 3.4 4.7 0.5 6.1 3.4 36 7 44 165 2.1 0 2.3 1.8 01/07/2006 15:00:00 4.5 0.7 6.5 2.6 4.5 0.7 6.8 2.6 4.3 0.7 6.5 2.3 58 10 53 165 2.1 0 2.3 2.1 01/07/2006 15:10:00 5.2 0.8 6.8 3.4 5.4 0.9 7.2 3.4 5 0.8 6.8 3.4 82 15 92 165 2.3 0.1 2.6 2.3 01/07/2006 15:20:00 5.6 0.8 7.2 3.4 5.8 0.8 7.2 3.4 5.3 0.8 7.2 3.4 94 7 101 165 2.4 0 2.8 2.6 01/07/2006 15:30:00 5.5 0.8 7.2 3 5.7 0.8 7.6 3.4 5.3 0.8 7.6 3.4 90 8 82 165 2.4 0 2.6 2.6 01/07/2006 15:40:00 8 1.2 11.1 5.3 8.2 1.3 11.5 5.3 7.6 1.2 10.7 4.9 101 12 102 165 2.5 0 2.8 2.6 01/07/2006 15:50:00 6.7 0.6 8.8 4.2 6.8 0.6 8.4 4.6 6.4 0.6 8 4.6 105 7 126 165 2.5 0 2.6 2.6 01/07/2006 16:00:00 7.2 1.2 10.7 4.9 7.3 1.3 11.1 5.3 6.8 1.3 9.9 4.2 104 8 107 165 2.5 0 2.6 2.3 01/07/2006 16:10:00 8.6 1 11.8 6.5 8.8 1 12.2 6.5 8.1 1 11.5 5.7 108 9 98 165 2.3 0 2.6 2.1 01/07/2006 16:20:00 8.4 0.8 10.3 6.1 8.6 0.8 10.3 6.1 7.9 0.9 10.3 5.3 108 5 106 165 2.3 0 2.3 2.3 01/07/2006 16:30:00 7.8 0.9 9.5 5.3 8 0.9 9.5 4.9 7.4 1 9.5 4.9 100 5 94 165 2.2 0 2.6 2.1 01/07/2006 16:40:00 7.6 0.9 9.9 4.9 7.7 0.9 9.9 4.6 7 0.9 9.5 4.9 102 7 99 165 2.2 0 2.3 2.1 01/07/2006 16:50:00 8.3 1.4 11.5 5.3 8.5 1.5 11.5 4.9 7.7 1.4 11.1 3.8 99 8 94 165 2.3 0 2.6 2.3 01/07/2006 17:00:00 8.5 1 10.7 6.1 8.7 1 11.1 6.1 8 1 10.3 5.3 96 7 97 165 2.1 0 2.6 1.8 01/07/2006 17:10:00 8 1.1 10.3 5.7 8.2 1.1 10.7 5.7 7.7 1 10.3 4.9 91 7 87 165 2.2 0 2.3 2.1 01/07/2006 17:20:00 8 0.9 9.9 5.3 8.1 0.9 10.3 5.7 7.4 1 9.5 5.3 90 9 79 165 2.2 0 2.3 2.1 01/07/2006 17:30:00 8.4 0.9 10.3 6.1 8.7 0.9 10.7 6.1 8 1 9.9 5.3 90 6 84 165 2.1 0 2.3 1.8 01/07/2006 17:40:00 8.7 1.1 11.1 6.1 8.9 1.1 11.1 6.1 8.2 1.1 10.3 5.7 92 6 92 165 2 0 2.3 1.8 01/07/2006 17:50:00 8.3 1 11.1 6.1 8.5 1 11.1 6.1 7.7 0.9 9.9 5.7 96 8 98 165 2 0 2.3 1.8 01/07/2006 18:00:00 7.7 1 10.3 4.9 7.9 1 10.3 4.9 7.4 1.1 10.3 4.9 90 8 83 165 2.1 0 2.3 1.8 01/07/2006 18:10:00 8.6 0.9 11.1 6.5 8.8 0.9 11.1 6.1 8.3 1 10.7 5.3 85 6 90 165 2 0 2.3 1.8 01/07/2006 18:20:00 7.5 0.9 9.5 5.3 7.7 0.9 9.9 5.3 7.2 0.9 9.5 4.6 84 6 87 165 2 0 2.3 1.8 01/07/2006 18:30:00 7.3 0.8 9.5 5.3 7.5 0.8 9.5 4.9 7 0.7 8.4 4.9 79 7 80 165 2.1 0 2.3 1.8 01/07/2006 18:40:00 8 1.2 10.3 4.9 8.2 1.2 10.7 4.9 7.6 1.2 9.9 5.3 80 6 84 165 2.1 0 2.3 1.8 01/07/2006 18:50:00 6.5 1.5 9.5 3 6.7 1.5 9.5 3 6.4 1.3 9.1 3.4 69 9 66 165 2.2 0 2.3 2.1 01/07/2006 19:00:00 7.8 0.8 9.5 5.3 8 0.9 9.5 5.3 7.4 0.9 9.1 5.3 73 7 84 165 2.2 0 2.3 2.1 01/07/2006 19:10:00 6 1.5 9.5 3 6.2 1.5 9.5 3 5.9 1.4 9.1 3 65 8 65 165 2.3 0 2.6 2.3 01/07/2006 19:20:00 7.4 1.3 10.3 3.8 7.6 1.3 10.3 4.2 7.2 1.2 9.9 4.6 62 11 65 165 2.3 0 2.6 2.3 01/07/2006 19:30:00 6.6 1.2 9.9 3.4 6.8 1.2 9.9 3.8 6.5 1.1 10.3 3.8 78 9 67 165 2.3 0 2.6 2.3 01/07/2006 19:40:00 7.2 1.2 10.3 4.6 7.4 1.2 10.3 4.6 6.9 1.1 9.9 4.6 71 9 69 165 2.3 0 2.6 2.3 01/07/2006 19:50:00 6 1.5 9.9 3 6.2 1.5 9.5 3.4 5.9 1.5 9.5 3 76 8 82 165 2.3 0 2.6 2.3 01/07/2006 20:00:00 4.6 0.7 6.8 2.6 4.8 0.7 6.8 3 4.3 0.6 6.5 2.6 80 7 75 165 2.3 0 2.3 2.3 01/07/2006 20:10:00 4.4 0.7 6.5 2.6 4.6 0.8 6.8 2.6 4.2 0.7 6.1 2.6 80 9 65 165 2.4 0 2.6 2.3 01/07/2006 20:20:00 5.6 1.1 8.8 3 5.9 1.1 8.8 3 5.5 1 7.6 3 81 9 106 165 2.4 0 2.6 2.3 01/07/2006 20:30:00 5.9 1.2 8.8 3 6.2 1.2 8.8 3.4 5.9 1.1 8.8 3 83 7 87 165 2.6 0 2.8 2.6 01/07/2006 20:40:00 6.3 1.3 9.1 3.4 6.5 1.3 9.5 3.8 6.2 1.3 9.1 3.4 80 9 94 165 2.7 0 2.8 2.6 01/07/2006 20:50:00 5.9 0.9 7.6 3.4 6.1 1 8 3.8 5.7 0.8 8 3.4 68 11 80 165 2.7 0 2.8 2.6 01/07/2006 21:00:00 5.5 1.1 8 2.6 5.6 1.1 8.4 3 5.1 1 7.2 2.6 60 12 84 165 2.8 0 3 2.8 01/07/2006 21:10:00 5.4 1 8.4 3.4 5.6 1 8.8 3.4 5.2 1 8 3 66 10 74 165 2.8 0 3 2.8 01/07/2006 21:20:00 6.2 1 9.5 3.8 6.3 1.1 9.5 3.8 6 1.1 8.4 3.4 66 9 77 165 2.6 0 2.8 2.6 01/07/2006 21:30:00 6.7 1.2 10.7 3.8 6.8 1.3 11.1 4.2 6.3 1.3 11.8 3.8 83 18 99 165 2.9 0 3 2.6 01/07/2006 21:40:00 5.7 1 8.4 3.4 5.9 1 9.1 3.4 5.6 1 8.4 3 72 13 43 165 2.9 0 3 2.8 01/07/2006 21:50:00 6.1 1.1 8.8 3.8 6.2 1.1 9.1 3.4 5.8 1 8.4 3.8 78 9 58 165 2.9 0 3 2.8 01/07/2006 22:00:00 5.9 1.1 9.9 4.2 6 1.2 10.3 3.4 5.6 1.2 9.9 3.4 72 11 79 165 2.8 0 3 2.8 01/07/2006 22:10:00 7 1.4 10.7 4.2 7.1 1.5 11.1 4.2 6.7 1.3 10.7 3.8 80 12 98 165 2.9 0 3 2.8 01/07/2006 22:20:00 7.2 1.2 10.3 4.2 7.4 1.2 10.7 4.2 6.9 1.1 10.3 4.6 80 11 89 165 2.9 0 3 2.8 01/07/2006 22:30:00 6.2 1.1 8.8 3.8 6.4 1.1 8.8 3.8 5.9 1 8.8 4.2 66 11 67 165 2.9 0 3 2.8 01/07/2006 22:40:00 8 1.3 10.7 4.9 8.3 1.4 11.1 4.9 7.6 1.3 10.3 4.2 75 9 77 165 2.9 0 3 2.8 01/07/2006 22:50:00 7.8 1.5 10.7 3.8 8.1 1.5 10.7 3.8 7.5 1.5 10.3 3.8 77 11 78 165 2.9 0 3 2.8 01/07/2006 23:00:00 5.2 1 8 2.6 5.3 1 7.6 2.3 4.9 0.9 6.8 2.3 56 11 56 165 2.9 0 3 2.8 01/07/2006 23:10:00 6.1 1.1 9.5 3.8 6.2 1.2 9.5 3.4 5.7 1.1 9.1 3.8 63 11 37 165 2.9 0 3 2.8 01/07/2006 23:20:00 6.5 1.2 9.1 3.8 6.7 1.3 9.1 3.8 6.3 1.3 8.4 3.4 71 9 73 165 2.9 0 3 2.8 01/07/2006 23:30:00 5.8 1.2 9.5 3 5.9 1.2 9.9 3 5.5 1.1 9.5 3 63 12 50 165 2.9 0 3 2.8 01/07/2006 23:40:00 4.8 1 7.6 2.6 4.9 1.1 7.6 2.6 4.7 1 6.5 3 62 9 54 165 3 0 3.3 2.8 01/07/2006 23:50:00 5.4 1.1 8.8 3 5.6 1.2 8.8 3 5.2 1.2 8.8 2.3 71 12 75 165 3 0 3.3 2.8 01/08/2006 00:00:00 5.6 1.2 8.8 3 5.7 1.2 9.5 3 5.3 1.2 8 3 72 9 58 165 3 0 3.3 3 01/08/2006 00:10:00 5.5 1.2 8 3.4 5.7 1.2 8.4 3.4 5.3 1.1 7.6 3 76 7 73 165 3 0 3.3 3 01/08/2006 00:20:00 5.3 0.9 7.6 2.6 5.4 1 7.6 2.6 5.2 0.8 6.8 3 76 9 88 165 3 0 3.3 3 01/08/2006 00:30:00 5.7 1.2 8.4 3.4 5.9 1.2 8.4 3.4 5.5 1.2 7.6 3 72 9 71 165 3 0 3.3 3 01/08/2006 00:40:00 4.8 0.9 6.8 3 5 0.9 6.8 3 4.7 0.9 6.5 2.6 69 7 62 165 3 0 3.3 3 01/08/2006 00:50:00 4.8 0.8 6.5 2.6 4.9 0.9 6.8 2.6 4.6 0.8 6.5 3 61 9 65 165 3 0 3.3 2.8 01/08/2006 01:00:00 4.5 0.9 6.5 2.3 4.5 1 6.8 2.3 4.2 1 6.5 1.9 55 9 47 165 2.9 0 3 2.8 01/08/2006 01:10:00 4.4 0.9 6.5 2.3 4.4 0.9 6.5 2.3 4.2 0.9 6.5 1.9 51 11 49 165 3 0 3 2.8 01/08/2006 01:20:00 4.9 0.6 6.1 3.4 5 0.6 6.5 3.4 4.8 0.6 6.5 3.4 58 7 52 165 3 0 3.3 2.8 01/08/2006 01:30:00 4.5 0.6 5.7 3 4.6 0.6 5.7 3 4.3 0.6 5.3 2.3 59 7 54 165 3 0 3.3 2.8 01/08/2006 01:40:00 4.4 0.6 5.7 3 4.4 0.6 5.7 3 3.9 0.6 5.7 2.6 57 8 55 165 3 0 3 2.8 01/08/2006 01:50:00 4.1 0.5 5.7 2.6 4.1 0.6 5.3 2.6 3.8 0.5 5.3 2.6 41 7 44 165 3 0 3.3 3 01/08/2006 02:00:00 4.4 0.4 4.9 3.4 4.3 0.4 4.9 3 4.1 0.4 4.9 2.6 36 4 40 165 3.2 0 3.3 3 01/08/2006 02:10:00 4.3 0.4 5.3 3 4.2 0.4 5.3 3 4 0.5 5.3 2.3 37 6 34 165 3.2 0 3.3 3 01/08/2006 02:20:00 4.5 0.5 6.5 3 4.6 0.6 6.5 3 4.2 0.6 5.7 3 48 6 49 165 3.3 0 3.5 3.3 01/08/2006 02:30:00 4.4 0.6 6.1 2.6 4.6 0.7 6.5 2.6 4.2 0.7 5.7 2.6 76 13 78 165 3.3 0 3.5 3.3 01/08/2006 02:40:00 4.1 0.8 6.1 2.6 4.3 0.8 6.5 2.6 4.1 0.8 6.1 2.6 78 7 93 165 3.4 0 3.5 3.3 01/08/2006 02:50:00 4.1 0.7 5.7 2.6 4.2 0.7 5.7 3 3.9 0.6 5.3 2.6 72 8 65 165 3.3 0 3.5 3.3 01/08/2006 03:00:00 4.2 0.6 5.7 2.3 4.3 0.6 5.7 2.6 4.1 0.7 5.7 2.3 78 7 70 165 3.2 0 3.5 3.3 01/08/2006 03:10:00 5.3 0.7 7.6 3.8 5.5 0.7 7.2 3.8 5.2 0.8 7.2 3 85 7 84 165 3.3 0 3.5 3.3 01/08/2006 03:20:00 6.5 0.9 8.8 4.2 6.6 1 9.1 4.2 6.1 0.9 8.4 3.8 89 8 94 165 3.2 0 3.5 3 01/08/2006 03:30:00 7.4 0.8 8.8 4.9 7.6 0.9 9.1 4.9 7 0.9 8.8 4.6 84 6 89 165 3 0 3.3 2.8 01/08/2006 03:40:00 5.3 0.9 7.2 2.6 5.5 1 7.6 3 5.1 1 7.6 2.6 73 8 84 165 2.9 0 3 2.8 01/08/2006 03:50:00 3.9 0.9 6.5 0.7 4 1 6.5 0.4 3.8 0.9 6.1 1.9 59 13 66 165 2.9 0 3 2.8 01/08/2006 04:00:00 5.1 0.9 7.2 3 5.2 0.9 7.2 3 4.9 0.8 7.2 3.4 80 8 83 165 2.9 0 3 2.8 01/08/2006 04:10:00 7.6 1.1 10.3 4.9 7.8 1.1 10.3 5.3 7.3 1 9.9 4.6 83 11 98 165 2.9 0 3.3 2.8 01/08/2006 04:20:00 5.4 1 8 3.4 5.6 1 8.4 3 5.3 0.9 7.6 3.4 61 10 68 165 2.7 0 2.8 2.8 01/08/2006 04:30:00 4.8 0.7 7.2 2.6 5 0.8 7.2 3 4.7 0.8 6.8 3 53 12 74 165 2.7 0 2.8 2.6 01/08/2006 04:40:00 5.2 0.7 7.2 3 5.1 0.8 7.2 3 4.9 0.8 6.8 2.3 40 9 39 165 2.7 0 2.8 2.6 01/08/2006 04:50:00 5.3 0.7 7.2 3.8 5.3 0.7 7.2 3.8 5 0.7 6.8 3 44 9 53 165 2.6 0 2.8 2.6 01/08/2006 05:00:00 6.6 1 9.5 4.2 6.5 1.1 9.1 4.2 6 1 8.8 3.8 45 8 54 165 2.7 0 2.8 2.6 01/08/2006 05:10:00 6.6 0.7 8.4 4.9 6.6 0.7 8.4 4.9 6.2 0.7 8.4 3.8 40 7 51 165 2.7 0 2.8 2.6 01/08/2006 05:20:00 7.3 0.5 8.8 5.3 7.3 0.6 8.4 5.3 6.8 0.7 8.4 4.2 40 5 40 165 2.7 0 2.8 2.6 01/08/2006 05:30:00 6.9 0.8 8.8 4.9 6.9 0.8 8.8 4.6 6.5 0.8 8.4 4.2 35 6 29 165 2.8 0 2.8 2.8 01/08/2006 05:40:00 6.9 0.9 9.5 4.6 6.8 1 9.1 4.2 6.5 0.9 9.1 4.6 31 10 19 165 2.9 0 3 2.8 01/08/2006 05:50:00 8.1 1 10.7 5.7 8.1 1 10.7 5.7 7.7 1 10.3 4.9 42 6 44 165 2.9 0 3 2.8 01/08/2006 06:00:00 8.8 1.3 13 5.7 8.7 1.4 13 5.3 8.5 1.5 13 5.3 36 8 33 165 2.6 0.1 3 2.6 01/08/2006 06:10:00 8.8 1.2 11.8 5.3 8.7 1.3 12.2 5.3 8.3 1.3 11.8 5.3 36 8 34 165 2.7 0 2.8 2.6 01/08/2006 06:20:00 9.7 1.2 12.6 6.1 9.6 1.2 12.2 6.1 9.2 1.3 11.8 6.1 30 8 25 165 2.8 0 2.8 2.6 01/08/2006 06:30:00 10.9 1.5 14.1 6.5 10.8 1.5 14.1 6.8 10.4 1.6 14.1 6.8 31 8 32 165 2.9 0 3 2.8 01/08/2006 06:40:00 10.9 1.3 14.9 7.6 10.9 1.4 14.9 7.2 10.8 1.4 14.1 7.6 37 8 29 165 2.7 0 3 2.6 01/08/2006 06:50:00 8.6 1.2 11.5 5.3 8.6 1.2 11.8 5.3 8.3 1.1 11.8 4.9 37 6 31 165 3 0.1 3.3 2.8 01/08/2006 07:00:00 8.2 1.5 12.2 4.6 8 1.5 12.6 4.6 7.9 1.5 12.2 4.6 30 8 33 165 3.2 0 3.3 3 01/08/2006 07:10:00 8.5 1.3 11.5 4.9 8.2 1.3 11.1 4.6 8 1.4 11.5 4.6 24 9 44 165 3 0 3.3 3 01/08/2006 07:20:00 7.8 1.1 11.1 5.3 6.9 1 10.3 4.6 7.5 1.3 11.1 5.3 16 9 11 165 3 0 3.3 3 01/08/2006 07:30:00 8.9 1.2 12.2 5.7 8.4 1.5 12.2 4.9 8.5 1.3 11.8 5.7 26 13 31 165 3 0 3.3 3 01/08/2006 07:40:00 8.7 1.7 13 5.3 8.5 1.7 13 4.6 8.4 1.5 12.6 5.3 27 8 31 165 2.9 0 3.3 2.8 01/08/2006 07:50:00 9.2 1.9 13.7 5.3 9.1 2 14.1 4.9 8.8 1.9 13.3 5.3 32 10 42 165 3 0 3.3 2.8 01/08/2006 08:00:00 9.1 1.1 11.8 6.1 9.1 1.1 11.8 6.1 8.7 1.1 11.8 6.5 41 7 35 165 3 0 3.3 3 01/08/2006 08:10:00 10.2 1.4 13.7 6.1 10.1 1.4 13.7 6.1 9.8 1.4 13.3 6.5 34 10 41 165 3.2 0 3.3 3 01/08/2006 08:20:00 10.3 1.3 13 6.8 10.2 1.5 13 6.8 10 1.5 13.3 5.7 29 8 28 165 3.1 0.1 3.5 3 01/08/2006 08:30:00 8.8 1.1 11.5 6.1 8.5 1.2 11.1 5.7 8.4 1.1 11.1 6.1 24 9 23 165 3.2 0 3.3 3 01/08/2006 08:40:00 8.9 1.1 11.5 4.9 8.5 1.2 11.1 4.6 8.4 1.1 11.5 5.3 23 8 18 165 3.3 0 3.5 3.3 01/08/2006 08:50:00 9.5 1.4 13 5.7 9 1.5 13 5.3 9.3 1.4 13 6.5 21 9 10 165 3.3 0 3.5 3.3 01/08/2006 09:00:00 10.7 1.3 13.7 7.6 9.9 1.5 13.3 6.1 10.3 1.5 13.7 6.5 17 7 12 165 3.2 0 3.5 3.3 01/08/2006 09:10:00 9 1.4 11.8 4.6 8.8 1.5 11.8 4.6 9 1.2 11.5 6.1 25 8 28 165 3.3 0 3.5 3.3 01/08/2006 09:20:00 9.6 1.5 13.3 6.1 9.3 1.5 13.3 5.7 9.2 1.5 13.3 6.1 25 10 25 165 3.5 0 3.5 3.5 01/08/2006 09:30:00 8.7 1.3 11.8 4.9 8.6 1.3 11.8 4.9 8.3 1.3 11.8 5.3 26 9 28 165 3.5 0 3.5 3.5 01/08/2006 09:40:00 9.4 1.4 12.6 4.9 9 1.5 12.6 4.2 9 1.5 13 4.9 24 10 18 165 3.6 0 3.5 3.5 01/08/2006 09:50:00 10.6 1.6 14.1 6.8 10.4 1.7 14.1 6.1 10.3 1.7 15.3 6.5 26 8 26 165 3.3 0.1 3.8 3 01/08/2006 10:00:00 9.9 1.5 13.7 6.5 9.4 1.5 13.3 4.9 9.5 1.5 13.3 5.7 19 8 18 165 3.3 0 3.5 3.3 01/08/2006 10:10:00 9.8 1.2 12.6 6.5 8.7 1.5 11.8 5.7 9.4 1.3 13 6.1 13 8 22 165 3.2 0 3.5 3 01/08/2006 10:20:00 8.6 1 11.1 6.1 7.5 1.3 10.7 4.2 8.4 1 11.1 5.7 12 7 15 165 3.1 0 3.3 3 01/08/2006 10:30:00 10.9 1.3 14.9 7.6 9.2 1.5 13.7 5.7 10.5 1.3 14.9 6.8 11 7 11 165 3.2 0 3.3 3 01/08/2006 10:40:00 10.4 1.3 13.7 7.2 8.7 1.4 12.6 5.7 10 1.3 13 6.8 10 7 18 165 3.3 0 3.5 3.3 01/08/2006 10:50:00 11.1 1.3 14.1 6.5 9.2 1.7 13.3 5.7 10.6 1.5 14.1 6.8 9 8 17 165 3.5 0 3.5 3.3 01/08/2006 11:00:00 11.7 1.5 15.6 7.6 10.9 1.7 15.3 6.1 11.4 1.6 15.3 7.2 19 9 34 165 3.3 0.1 3.5 3 01/08/2006 11:10:00 10.2 1.2 13 6.8 10.2 1.3 13.3 6.8 9.9 1.4 13.3 6.5 36 8 45 165 3 0.1 3.3 2.8 01/08/2006 11:20:00 8.9 1.1 11.1 5.7 8.8 1.2 11.5 5.3 8.5 1.1 11.1 4.9 34 12 47 165 3.3 0.1 3.5 3 01/08/2006 11:30:00 7 0.9 9.9 4.9 6.1 1 8.4 3.8 6.8 0.9 9.5 4.9 14 8 10 165 3.6 0 3.8 3.5 01/08/2006 11:40:00 6.2 0.8 8 4.2 5.7 0.9 8 3.4 6 0.8 8.4 3.8 19 9 11 165 3.8 0 4 3.8 01/08/2006 11:50:00 7 1.1 9.5 4.6 6 1.1 9.1 3 6.6 1 9.5 4.2 12 9 11 165 3.8 0 4 3.5 01/08/2006 12:00:00 7.3 0.9 9.9 4.9 6.5 1 9.5 4.6 7.1 1 9.1 4.9 15 8 18 165 3.6 0 3.8 3.5 01/08/2006 12:10:00 7.2 1.3 11.1 4.6 6.3 1.1 9.5 3.4 6.8 1.1 10.3 3.8 14 10 8 165 3.6 0 3.8 3.5 01/08/2006 12:20:00 7.6 1.1 11.5 4.6 7.4 1.2 10.7 4.2 7.3 1.2 10.7 3.4 28 11 14 165 3.6 0 3.8 3.5 01/08/2006 12:30:00 7.5 1 9.5 4.9 7.1 1 9.5 4.6 7.2 0.9 9.1 4.9 20 7 13 165 3.8 0 4 3.5 01/08/2006 12:40:00 6.6 1 8.8 3.8 6.4 1.1 8.8 3.8 6.4 1.2 9.1 3 22 8 38 165 3.8 0 4 3.5 01/08/2006 12:50:00 7.2 1 9.9 4.6 6.7 1.2 9.5 3.8 7.1 1 9.5 4.9 16 8 16 165 3.6 0 3.8 3.5 01/08/2006 13:00:00 6.8 0.9 9.1 4.9 6 1.1 8.8 3 6.7 0.8 9.1 4.6 14 7 6 165 3.6 0 3.8 3.5 01/08/2006 13:10:00 6.9 0.9 8.8 4.6 6 1.1 8.4 3 6.6 1 9.1 4.2 12 6 10 165 3.8 0 4.3 3.5 01/08/2006 13:20:00 7.2 0.9 9.5 4.6 6.4 1.1 8.8 3.4 7 1 9.9 4.9 14 7 15 165 3.9 0.2 4.3 3.5 01/08/2006 13:30:00 7.7 0.8 9.9 5.7 6.1 1.3 9.5 3.4 7.6 0.9 9.9 5.3 10 9 11 165 3.3 0 3.5 3.3 01/08/2006 13:40:00 7.3 1 9.9 4.2 5.8 1.4 9.5 2.6 6.9 1 9.9 4.6 6 10 15 165 3.4 0 3.5 3.3 01/08/2006 13:50:00 7.4 1.1 11.1 4.9 6.5 1.2 10.7 3.8 7.2 1.2 11.1 4.9 15 6 18 165 3.5 0 3.5 3.5 01/08/2006 14:00:00 7.2 1.1 9.5 4.2 6 1.5 9.1 2.6 7 1.2 9.5 4.2 12 6 15 165 3.5 0 3.8 3.5 01/08/2006 14:10:00 7.6 0.8 9.9 5.3 6.3 1.1 9.1 3.8 7.4 0.9 9.9 5.3 12 6 12 165 3.5 0 3.5 3.5 01/08/2006 14:20:00 7.5 1 10.7 5.3 6.3 1.2 9.5 3.4 7.3 1 10.7 5.3 12 7 14 165 3.5 0 3.8 3.3 01/08/2006 14:30:00 8.5 1.2 10.7 5.3 6.9 1.6 11.1 3.8 8.3 1.2 11.1 5.3 10 8 6 165 3.3 0 3.5 3 01/08/2006 14:40:00 9.6 0.9 11.8 6.5 8 1.6 11.5 4.6 9.5 1 11.8 6.8 11 6 16 165 2.9 0.1 3.3 2.6 01/08/2006 14:50:00 8.3 1 10.3 6.1 6.2 1.3 9.1 3.4 8.2 1.1 10.7 5.3 7 7 4 165 2.7 0 3 2.6 01/08/2006 15:00:00 8.7 1 11.1 6.5 6.7 1.3 9.9 3.4 8.6 1 11.5 6.5 7 7 0 165 3 0 3.3 2.8 01/08/2006 15:10:00 8.5 1 11.1 5.7 7.5 1.1 10.7 4.6 8.5 1.1 11.1 5.7 13 6 16 165 3.2 0.1 3.5 3 01/08/2006 15:20:00 8.3 1 11.1 6.5 6.6 1.5 10.7 3.8 8.2 1 11.1 5.7 6 9 15 165 2.8 0 3.3 2.8 01/08/2006 15:30:00 8.1 1.1 11.1 5.3 6.2 1.3 9.9 3.4 7.5 1.1 11.1 4.6 358 8 5 165 2.9 0 3 2.8 01/08/2006 15:40:00 7.2 1.3 10.7 4.6 5.4 1.2 8.8 3 6.9 1.4 10.3 4.2 359 8 2 165 3 0 3.3 2.8 01/08/2006 15:50:00 7.7 0.8 9.5 4.9 5.6 1.3 9.5 3.4 7.3 0.9 9.5 4.9 1 9 2 165 3.1 0 3.3 3 01/08/2006 16:00:00 7.8 1.1 11.1 5.3 6.1 1.5 10.7 3.4 7.4 1.1 11.1 5.3 5 10 19 165 3.1 0 3.3 3 01/08/2006 16:10:00 8.6 1 11.8 6.1 6.8 1.5 11.1 4.2 8.2 1 10.7 5.7 5 9 22 165 3.2 0 3.3 3 01/08/2006 16:20:00 7.7 1.1 10.7 3.8 6.3 1.3 10.3 3.4 7.3 1.3 11.1 3.4 4 11 15 165 3 0 3.3 3 01/08/2006 16:30:00 9.6 1.8 13.7 3.8 7.9 1.9 13 3.8 9.1 1.8 13 4.2 8 9 14 165 3.2 0 3.3 3 01/08/2006 16:40:00 10.2 1.3 13.3 6.5 8.4 1.7 12.6 4.2 9.9 1.4 13.7 6.8 9 7 18 165 3.2 0 3.5 3.3 01/08/2006 16:50:00 10.8 1.2 14.1 8 8.6 1.7 13.3 5.3 10.5 1.2 13.7 7.6 9 8 18 165 3.2 0 3.5 3 01/08/2006 17:00:00 8.4 1.1 10.7 5.7 6.8 1.1 9.5 4.2 8.1 1.1 10.3 5.3 9 8 3 165 3.2 0 3.5 3 01/08/2006 17:10:00 7.7 0.9 10.3 5.7 6.5 1.5 9.9 3 7.5 0.8 10.3 5.7 11 8 16 165 3.1 0 3.3 3 01/08/2006 17:20:00 6.8 0.9 8.8 4.6 5.9 1 8.4 3.4 6.7 1 9.1 4.2 349 12 3 165 2.9 0 3.3 2.6 01/08/2006 17:30:00 6.5 1.1 10.3 3.8 6 1.2 10.3 2.6 6.2 1.1 10.3 4.2 344 10 344 165 2.6 0 2.8 2.6 01/08/2006 17:40:00 6.8 0.7 9.1 4.6 5.9 1.2 9.1 3 6.3 0.8 8.8 3.8 350 8 352 165 2.4 0 2.6 2.3 01/08/2006 17:50:00 8.4 1.2 11.8 5.7 8 1.3 13 4.6 7.7 1.3 12.2 5.3 345 8 343 165 2.3 0 2.6 2.3 01/08/2006 18:00:00 8.3 1 10.7 5.3 7.5 1.3 10.7 3.8 8.2 0.9 10.3 5.7 347 9 357 165 2.4 0 2.6 2.3 01/08/2006 18:10:00 8.6 1.1 11.8 6.1 7.5 1.3 11.1 4.6 8.4 1.1 11.5 6.1 348 10 357 165 2.4 0 2.6 2.3 01/08/2006 18:20:00 7.3 0.8 9.5 5.7 6.8 1.1 9.5 3.8 7.5 0.8 9.9 5.3 348 6 348 165 2.4 0 2.6 2.3 01/08/2006 18:30:00 7.6 0.8 9.9 5.7 6.9 1.3 9.5 3.8 7.5 0.7 9.5 5.3 347 9 4 165 2.3 0 2.6 2.3 01/08/2006 18:40:00 9.6 1.4 13 5.7 8.7 1.7 13.3 5.3 9.2 1.6 13.7 5.3 346 9 350 165 2.5 0 2.8 2.3 01/08/2006 18:50:00 10.9 1.5 15.6 7.6 10.7 1.5 15.6 6.1 10.4 1.6 15.6 6.8 331 13 325 165 2.6 0 2.8 2.6 01/08/2006 19:00:00 9.1 1.4 12.2 5.3 9.1 1.3 11.8 5.7 8.1 1.7 11.8 3.4 325 12 321 165 2.7 0 2.8 2.6 01/08/2006 19:10:00 8.8 1.1 12.2 6.5 8.4 1.2 12.6 4.9 8.3 1.1 11.5 6.1 341 9 335 165 2.6 0 2.8 2.6 01/08/2006 19:20:00 11.1 1.6 15.3 8 11 1.6 16.1 8 10.8 1.7 15.3 7.6 330 9 328 165 2.5 0 2.8 2.6 01/08/2006 19:30:00 12.2 1.8 16.8 7.2 11.2 2 17.6 7.2 11.8 1.8 17.2 6.8 342 13 346 165 2.6 0 2.8 2.6 01/08/2006 19:40:00 12.1 1.3 18.3 9.1 10.9 1.9 15.3 6.1 12.1 1.5 17.9 8 349 10 358 165 2.8 0 2.8 2.6 01/08/2006 19:50:00 11.2 1.7 15.6 8 10.7 2.1 15.6 5.3 11.2 2 17.2 7.2 342 11 358 165 2.8 0 3 2.6 01/08/2006 20:00:00 9.2 0.9 11.8 6.8 8.9 1 11.5 6.5 9.1 0.8 11.5 6.8 342 9 0 165 2.6 0.1 2.8 2.6 01/08/2006 20:10:00 8.7 1.3 12.2 6.5 8.6 1.5 13 4.6 8.6 1.3 12.6 6.5 338 10 334 165 2.4 0 2.6 2.3 01/08/2006 20:20:00 11.2 1.4 15.6 8 10.6 1.3 14.5 7.2 11 1.5 16.1 7.6 343 14 358 165 2.6 0 2.8 2.6 01/08/2006 20:30:00 10.1 1.3 14.9 6.1 9.8 1.1 13.3 5.3 10.1 1.4 15.3 6.8 336 12 10 165 2.7 0 2.8 2.6 01/08/2006 20:40:00 10 2.1 14.9 6.5 9.3 2.3 15.6 4.9 9.9 2.1 15.3 6.5 342 11 1 165 2.6 0 2.8 2.6 01/08/2006 20:50:00 11.1 1.5 16.1 8 9.9 1.5 16.4 6.5 11.1 1.6 14.9 7.6 348 10 339 165 2.9 0 3 2.8 01/08/2006 21:00:00 9.3 1.4 13.3 6.1 8 1.3 11.8 5.3 9 1.6 13 5.3 352 12 352 165 2.8 0 3 2.8 01/08/2006 21:10:00 9.9 1.3 14.1 6.8 9.4 1.7 14.1 5.3 9.2 1.3 13 5.7 346 9 351 165 2.7 0 2.8 2.6 01/08/2006 21:20:00 9.3 1 11.8 6.5 8.1 1.5 11.8 4.2 9 1.1 11.5 6.1 350 8 348 165 2.6 0 2.8 2.6 01/08/2006 21:30:00 8.8 1.3 11.8 5.7 7.8 1.5 11.5 4.6 8.1 1.5 11.8 4.9 349 9 351 165 2.5 0 2.6 2.6 01/08/2006 21:40:00 8.4 1.1 10.7 4.9 7.4 1.3 10.3 4.2 7.8 1.1 10.3 4.6 350 7 342 165 2.4 0 2.6 2.3 01/08/2006 21:50:00 7.2 0.9 9.5 4.9 6.4 1.2 9.5 4.2 6.5 1 8.8 3.8 349 8 355 165 2.3 0 2.6 2.3 01/08/2006 22:00:00 8.7 1.3 11.5 4.6 7 1.9 11.8 3.8 8.3 1.4 12.2 4.6 355 9 339 165 2.3 0 2.6 2.3 01/08/2006 22:10:00 10.3 1.3 15.3 7.2 8.9 2 14.1 4.9 9.9 1.3 14.5 6.8 351 7 353 165 2.4 0 2.6 2.3 01/08/2006 22:20:00 9.6 1.2 13 6.5 8.3 1.5 11.8 4.9 9.1 1.3 12.6 5.3 351 8 355 165 2.4 0 2.6 2.3 01/08/2006 22:30:00 9.5 1.1 12.2 7.2 8.4 1.7 12.6 4.9 9 1.2 12.6 6.5 350 7 359 165 2.4 0 2.8 2.3 01/08/2006 22:40:00 9.6 1.7 14.5 6.1 8.8 1.7 14.1 4.9 9.1 1.7 13 5.7 346 8 359 165 2.5 0 2.6 2.3 01/08/2006 22:50:00 10.4 1.3 13.3 6.8 9.2 1.7 13.3 4.9 9.8 1.4 13 6.5 350 8 358 165 2.4 0 2.6 2.6 01/08/2006 23:00:00 9.3 1.1 13.3 6.5 9 1.4 13.3 4.9 8.7 1.2 13.3 5.7 345 7 351 165 2.6 0 2.8 2.6 01/08/2006 23:10:00 8.7 0.9 11.5 6.5 8.6 1.1 11.8 5.3 8.4 0.9 11.5 5.3 343 7 338 165 2.5 0 2.8 2.3 01/08/2006 23:20:00 7.8 1.1 10.7 4.9 7.3 1.5 11.5 4.2 7.4 1.1 9.9 5.3 346 8 339 165 2.4 0 2.6 2.6 01/08/2006 23:30:00 7.7 1 9.9 5.3 7.4 1.5 10.3 4.2 7.2 1 9.5 4.2 346 9 355 165 2.4 0 2.6 2.3 01/08/2006 23:40:00 7.8 1 10.3 4.9 7.5 1.3 11.5 4.2 7.4 1.1 10.7 4.6 345 9 341 165 2.4 0 2.6 2.6 01/08/2006 23:50:00 7.4 1.1 9.9 4.2 6.9 1.3 9.9 4.2 6.9 1.1 9.5 4.2 348 9 340 165 2.4 0 2.6 2.6 01/09/2006 00:00:00 7.7 0.9 9.9 5.3 6.6 1.5 10.3 3.4 7.4 1 9.9 4.9 353 8 344 165 2.6 0 2.8 2.6 01/09/2006 00:10:00 8.1 0.9 11.1 6.1 7.7 1.2 10.7 4.6 7.8 1 10.7 5.3 348 7 12 165 2.6 0 2.8 2.6 01/09/2006 00:20:00 7.5 0.9 10.3 5.3 7.2 0.9 9.5 4.9 7.2 1 10.3 4.6 347 9 8 165 2.7 0 2.8 2.6 01/09/2006 00:30:00 7.1 0.7 9.5 5.7 6.9 0.8 9.5 3.8 6.8 0.7 9.5 5.3 344 7 356 165 2.6 0 2.8 2.6 01/09/2006 00:40:00 6.8 0.6 9.1 5.3 6.6 0.7 9.1 4.2 6.5 0.7 8.8 4.9 341 8 335 165 2.5 0 2.8 2.3 01/09/2006 00:50:00 7.1 0.7 9.1 4.9 7 0.9 9.1 4.2 7 0.7 8.8 4.9 340 9 333 165 2.4 0 2.6 2.6 01/09/2006 01:00:00 9.4 1.2 12.6 6.1 8.4 1.3 12.2 5.7 9.4 1.2 12.6 6.5 348 9 354 165 2.5 0 2.6 2.6 01/09/2006 01:10:00 10.1 1.2 14.1 6.5 8.6 1.8 13.7 4.6 9.8 1.4 13.7 6.1 354 7 352 165 2.6 0 2.8 2.6 01/09/2006 01:20:00 10.7 1.7 14.9 6.1 9.3 1.7 13.7 6.1 10.4 1.7 13.7 5.7 351 12 4 165 2.7 0 2.8 2.6 01/09/2006 01:30:00 9 1.3 12.2 6.1 7.6 1.5 11.5 3.8 8.7 1.3 11.8 5.3 351 9 358 165 2.7 0 2.8 2.6 01/09/2006 01:40:00 8.9 1 11.8 6.5 8.2 1.3 11.1 4.9 8.5 1.1 11.1 5.7 343 12 6 165 2.5 0 2.8 2.6 01/09/2006 01:50:00 7.6 0.8 9.5 5.3 7.5 1 9.9 3.8 7.4 0.8 9.5 4.6 342 9 334 165 2.5 0 2.8 2.6 01/09/2006 02:00:00 9.5 1.2 13.3 6.5 9.5 1.2 13.3 5.7 9.1 1.2 13.7 6.5 332 9 316 165 2.6 0 2.8 2.6 01/09/2006 02:10:00 8.2 1.5 13.3 4.2 8 1.5 13.3 4.6 7.9 1.4 11.5 4.2 340 9 340 165 2.6 0 2.8 2.6 01/09/2006 02:20:00 8.5 1.2 12.2 5.3 8.5 1.3 12.2 4.9 8.2 1.2 11.8 5.3 339 8 332 165 2.6 0 2.8 2.6 01/09/2006 02:30:00 8.2 1 12.2 5.7 8.2 1.1 11.8 5.7 7.9 1 11.5 5.3 338 9 334 165 2.5 0 2.8 2.6 01/09/2006 02:40:00 8.4 1.7 12.2 4.2 7.7 1.6 12.6 4.2 8 1.5 11.8 5.3 345 10 5 165 2.6 0 2.8 2.6 01/09/2006 02:50:00 8.6 0.9 11.8 6.1 8 1.5 11.8 4.6 8.3 1 11.1 6.1 345 10 353 165 2.5 0 2.8 2.6 01/09/2006 03:00:00 10.1 1.9 14.5 5.7 10 1.9 14.1 5.7 9.5 2.1 13.7 5.3 330 9 330 165 2.6 0 2.8 2.6 01/09/2006 03:10:00 11.3 1.4 14.9 8 11.1 1.5 15.3 6.1 10.9 1.5 14.1 7.2 333 9 325 165 2.7 0 2.8 2.8 01/09/2006 03:20:00 9.8 1.6 13.7 6.1 9.7 1.5 13.7 6.1 8.8 1.7 13 4.6 326 8 312 165 2.7 0 2.8 2.8 01/09/2006 03:30:00 10 1.4 14.5 6.1 9.9 1.3 14.5 6.5 9.4 1.3 12.6 5.7 330 8 329 165 2.7 0 3 2.8 01/09/2006 03:40:00 9.8 1.4 14.9 5.3 9.7 1.4 14.5 5.7 9.1 1.5 14.1 5.7 330 10 341 165 2.7 0 2.8 2.6 01/09/2006 03:50:00 10.5 1.3 16.1 6.8 10.4 1.3 15.6 6.8 10.1 1.1 13 7.6 335 9 340 165 2.6 0 2.8 2.6 01/09/2006 04:00:00 9.6 1.2 13.3 5.3 9.5 1.3 13.3 4.2 9 1.4 13.3 4.6 333 10 330 165 2.5 0 2.8 2.6 01/09/2006 04:10:00 10.6 1 13 7.2 10.5 1.1 13 6.8 10.1 1.1 12.6 7.2 336 7 337 165 2.5 0 2.8 2.6 01/09/2006 04:20:00 10.6 1.3 13.7 8 10.5 1.3 13.3 6.5 10.3 1.5 13.3 6.8 339 7 340 165 2.5 0 2.6 2.6 01/09/2006 04:30:00 9.6 1.3 13 6.5 9.6 1.4 13.3 5.3 9.1 1.2 12.6 6.1 340 8 333 165 2.5 0 2.8 2.6 01/09/2006 04:40:00 9.1 1 12.2 6.1 9 1.2 12.2 6.1 8.4 1.1 11.1 5.7 339 10 338 165 2.5 0 2.8 2.6 01/09/2006 04:50:00 9.9 1.5 13 5.3 9.8 1.5 13.7 5.3 9 1.7 13 4.9 340 7 334 165 2.5 0 2.8 2.6 01/09/2006 05:00:00 9.9 1.1 14.1 6.8 9.5 1.5 14.1 6.1 8.8 1.2 12.6 3.8 342 8 349 165 2.5 0 2.8 2.6 01/09/2006 05:10:00 9.8 1.1 12.6 6.8 9.5 1.4 12.6 4.6 9 1.1 12.2 6.5 344 7 338 165 2.4 0 2.6 2.3 01/09/2006 05:20:00 10.3 1.4 14.9 6.1 10.3 1.3 14.9 6.5 9.3 1.3 12.6 5.7 340 8 347 165 2.4 0 2.8 2.3 01/09/2006 05:30:00 10.8 1.2 13.7 8 10.8 1.4 14.1 6.1 9.8 1.4 13 5.7 342 6 343 165 2.4 0 2.6 2.3 01/09/2006 05:40:00 10.7 1.1 13.7 7.6 10.6 1.5 14.1 5.7 9.7 1.2 13.3 6.8 343 7 347 165 2.5 0 2.8 2.6 01/09/2006 05:50:00 9.7 1.3 13.3 5.7 9.5 1.5 14.1 5.3 8.7 1.3 13 5.7 339 10 344 165 2.5 0 2.8 2.6 01/09/2006 06:00:00 8.9 1.2 12.2 6.5 8.8 1.2 12.2 5.3 8.4 1.3 11.8 5.3 342 8 342 165 2.4 0 2.6 2.3 01/09/2006 06:10:00 9.1 1.4 13.3 6.1 8.8 1.5 13.3 4.9 8.3 1.5 12.6 5.3 342 9 337 165 2.4 0 2.6 2.3 01/09/2006 06:20:00 8.8 1.3 12.2 6.1 8.7 1.3 11.8 5.7 8.1 1.3 11.8 4.6 337 10 354 165 2.4 0 2.6 2.3 01/09/2006 06:30:00 9.2 1.1 12.2 6.8 9 1.1 11.8 6.5 8.8 1.1 11.8 5.7 331 9 326 165 2.3 0 2.6 2.3 01/09/2006 06:40:00 8.5 1.2 11.8 5.7 8.4 1.2 12.2 5.7 8 1.1 11.5 5.7 332 10 336 165 2.4 0 2.6 2.3 01/09/2006 06:50:00 9.5 1.2 13 6.5 9.5 1.2 13 6.5 9.1 1.3 13 5.7 335 9 338 165 2.4 0 2.6 2.3 01/09/2006 07:00:00 10.6 1.5 14.5 6.8 10.6 1.6 15.6 6.5 10.4 1.6 14.1 7.2 341 7 342 165 2.4 0 2.6 2.3 01/09/2006 07:10:00 11.7 1.2 15.6 8.4 11.7 1.5 16.8 7.6 11.5 1.2 15.6 8 341 7 341 165 2.4 0 2.6 2.3 01/09/2006 07:20:00 12.2 1.2 14.9 8.4 12.2 1.3 15.3 8.4 12.1 1.4 15.3 8.4 337 7 341 165 2.4 0 2.6 2.3 01/09/2006 07:30:00 11.6 1.5 14.5 8 11.5 1.5 14.5 8 11.1 1.5 14.5 7.6 332 8 334 165 2.4 0 2.6 2.3 01/09/2006 07:40:00 10.7 1.3 13.7 7.6 10.5 1.3 13.7 6.8 10.2 1.3 13.3 6.8 335 9 336 165 2.4 0 2.8 2.3 01/09/2006 07:50:00 9.9 1.3 13.7 6.5 9.8 1.5 14.1 5.3 9.5 1.5 13.3 6.1 338 10 344 165 2.5 0 2.8 2.6 01/09/2006 08:00:00 11 1.5 13.7 6.5 10.9 1.6 14.1 6.8 10.5 1.6 13.7 6.5 336 8 336 165 2.6 0 2.8 2.6 01/09/2006 08:10:00 10.5 1.5 14.5 6.5 10.2 1.8 14.1 4.9 10.1 1.5 14.5 6.5 339 10 348 165 2.6 0 2.8 2.6 01/09/2006 08:20:00 9.9 1.2 13.3 7.2 9.6 1.3 14.1 5.3 9.4 1.4 13 5.7 335 12 349 165 2.6 0 2.8 2.6 01/09/2006 08:30:00 9.7 1.4 13.3 6.1 9.3 1.5 13.3 4.2 9 1.4 12.2 4.9 339 11 339 165 2.7 0 2.8 2.6 01/09/2006 08:40:00 10.5 1.5 14.1 5.3 10.4 1.6 14.5 5.7 10 1.5 14.1 6.1 335 8 338 165 2.7 0 2.8 2.6 01/09/2006 08:50:00 9.5 1.5 14.9 5.7 9.4 1.6 14.9 5.3 8.9 1.4 13.7 5.3 339 10 348 165 2.7 0 2.8 2.6 01/09/2006 09:00:00 9.7 1.4 12.6 6.5 9.4 1.5 12.6 4.9 8.9 1.5 12.2 5.7 341 8 349 165 2.7 0 3 2.8 01/09/2006 09:10:00 10.1 1.4 13 6.8 9.8 1.7 13.3 4.9 9 1.4 11.8 4.2 344 8 350 165 2.7 0 2.8 2.6 01/09/2006 09:20:00 9.8 1.4 13.3 6.1 9.7 1.4 12.6 6.1 9 1.5 12.6 5.7 338 7 329 165 2.5 0 2.8 2.6 01/09/2006 09:30:00 10.9 1.4 14.1 5.7 10.8 1.5 13.7 6.5 10.3 1.5 14.1 6.5 334 9 334 165 2.4 0 2.8 2.3 01/09/2006 09:40:00 10.6 1.4 14.5 7.2 10.5 1.5 13.7 5.7 10.2 1.5 14.1 6.1 336 8 332 165 2.4 0 2.6 2.3 01/09/2006 09:50:00 10.5 1.7 14.9 6.1 10.4 1.7 14.5 6.1 10.4 1.7 13.7 6.1 335 8 337 165 2.4 0 2.6 2.3 01/09/2006 10:00:00 9.8 1.3 13 6.1 9.8 1.4 13 6.1 9.6 1.4 13 6.1 337 9 350 165 2.5 0 2.8 2.6 01/09/2006 10:10:00 8.3 1.9 13 4.6 8.3 1.9 13 4.6 8.1 2.1 13 4.2 330 12 341 165 2.5 0 2.6 2.6 01/09/2006 10:20:00 9.1 1.3 12.6 5.7 9 1.3 12.2 5.7 7.4 0.9 9.5 4.9 307 11 309 165 2.4 0 2.6 2.3 01/09/2006 10:30:00 10.7 1 13 6.8 10.6 1 12.6 6.8 8.4 1.2 11.8 5.3 298 7 289 165 2.4 0 2.6 2.3 01/09/2006 10:40:00 11 1.3 14.5 7.2 10.9 1.3 13.7 6.8 8.4 1.2 12.6 6.1 298 8 298 165 2.4 0 2.6 2.3 01/09/2006 10:50:00 10.2 1.3 13.3 6.5 10.1 1.2 13.3 6.1 8.8 1.5 12.6 4.2 309 9 301 165 2.4 0 2.6 2.3 01/09/2006 11:00:00 10.4 1.1 13.7 6.8 10.3 1.1 13 6.8 9 1.2 13 4.9 309 9 295 165 2.4 0 2.6 2.3 01/09/2006 11:10:00 10.5 1.1 12.6 6.8 10.3 1.1 12.2 6.5 8.2 1.1 11.5 5.3 303 7 300 165 2.6 0 2.8 2.6 01/09/2006 11:20:00 10.3 1.2 13 6.8 10.1 1.2 13 6.5 7.9 1 11.5 5.3 303 6 307 165 2.7 0 2.8 2.6 01/09/2006 11:30:00 11.2 1 14.5 8 11 1 13.7 7.6 8.6 1.1 11.8 5.7 304 5 298 165 2.7 0 2.8 2.6 01/09/2006 11:40:00 11.1 1.2 15.6 7.6 11 1.2 16.1 7.2 8.9 1.3 14.1 5.7 306 7 316 165 2.6 0 2.8 2.6 01/09/2006 11:50:00 11.4 1.4 14.5 8 11.3 1.3 14.5 7.6 9 1.4 13 5.7 301 7 310 165 2.5 0 2.8 2.3 01/09/2006 12:00:00 12.3 1.4 15.3 8.4 12.2 1.3 14.9 8.4 9.4 1.3 12.6 5.7 302 6 295 165 2.4 0 2.6 2.3 01/09/2006 12:10:00 11.3 1.4 14.9 6.5 11.1 1.3 14.5 6.8 9 1.5 13.3 5.3 303 7 302 165 2.5 0 2.8 2.6 01/09/2006 12:20:00 10.8 1.3 13.7 7.6 10.7 1.2 13.3 8 9.1 1.4 13.3 5.3 308 9 310 165 2.6 0 2.8 2.6 01/09/2006 12:30:00 10.1 1.3 13.3 6.8 9.9 1.2 13.3 6.8 8.2 1.3 12.2 4.6 305 8 298 165 2.5 0 2.8 2.6 01/09/2006 12:40:00 11.1 1.6 14.5 6.1 11 1.5 14.1 6.5 8.8 1.5 12.6 5.3 300 8 295 165 2.4 0 2.8 2.3 01/09/2006 12:50:00 11.1 1.8 14.9 5.3 10.9 1.7 14.5 5.3 8.8 1.7 13.7 4.2 300 10 301 165 2.3 0 2.6 2.3 01/09/2006 13:00:00 8.9 1.6 12.2 4.9 8.8 1.6 12.2 4.6 7.6 1.6 11.8 3.4 311 10 308 165 2.4 0 2.6 2.3 01/09/2006 13:10:00 9.4 1.4 13 5.7 9.3 1.3 13 5.3 7.9 1.3 11.1 3.4 308 10 301 165 2.4 0 2.6 2.3 01/09/2006 13:20:00 10.1 1.4 13.3 6.1 10 1.3 13 6.1 8.6 1.3 11.8 5.7 308 9 308 165 2.4 0 2.6 2.3 01/09/2006 13:30:00 9.1 1.4 12.2 6.1 8.9 1.4 12.2 6.1 8.3 1.4 11.8 4.2 317 10 309 165 2.4 0 2.6 2.3 01/09/2006 13:40:00 9.3 1.3 12.6 6.1 9.2 1.3 12.2 6.5 8.2 1.4 12.2 4.2 312 11 302 165 2.4 0 2.6 2.3 01/09/2006 13:50:00 9.3 1.2 11.8 6.1 9.2 1.2 12.2 6.1 8.9 1.2 12.6 5.7 324 9 320 165 2.6 0 2.8 2.3 01/09/2006 14:00:00 9 1.3 11.8 6.1 8.8 1.2 11.8 6.1 7.4 1.1 10.3 4.6 305 9 292 165 2.4 0 2.8 2.3 01/09/2006 14:10:00 8.9 1.2 11.8 5.7 8.8 1.2 11.8 6.1 7.7 1.1 10.7 4.9 310 10 292 165 2.4 0 2.6 2.3 01/09/2006 14:20:00 9.1 1.2 12.6 6.5 9.1 1.3 13 6.5 8.7 1.2 12.2 6.1 332 9 338 165 2.9 0.2 3.3 2.6 01/09/2006 14:30:00 10.1 1.3 14.9 6.5 10.1 1.4 15.3 6.8 9.8 1.4 13.7 6.8 336 9 348 165 3.3 0 3.5 3.3 01/09/2006 14:40:00 9 1.3 12.6 5.3 8.9 1.3 12.2 5.3 8.7 1.3 12.6 5.3 333 9 336 165 3.2 0 3.5 3 01/09/2006 14:50:00 7.2 1.7 12.2 3.8 6.9 1.7 12.6 3.8 6.8 2 12.2 3 329 13 355 165 3.2 0 3.5 3 01/09/2006 15:00:00 6.4 1.2 9.5 4.2 6.3 1.1 9.5 3.8 5.8 1.1 9.9 3.4 327 13 344 165 3.1 0 3.3 3 01/09/2006 15:10:00 3.8 1.1 7.6 1.5 3.4 1 7.2 1.1 3.4 1.2 7.2 0.7 326 22 340 165 3 0 3.3 3 01/09/2006 15:20:00 5.3 1.1 8.4 2.6 5.2 1.1 8.4 2.6 4.6 1.2 8.4 2.3 312 16 338 165 3 0 3.3 2.8 01/09/2006 15:30:00 5.7 0.8 8 3.4 5.6 0.8 7.6 3.4 4.7 0.9 7.2 2.3 295 11 293 165 2.6 0.2 3 2.3 01/09/2006 15:40:00 6.7 0.8 8.8 4.6 6.6 0.9 9.1 4.6 5.6 0.9 9.1 3.4 303 9 295 165 2.5 0 2.6 2.3 01/09/2006 15:50:00 6.8 0.8 9.1 4.9 6.8 0.8 9.1 4.9 6.1 0.8 8 4.2 312 7 302 165 2.5 0 2.6 2.3 01/09/2006 16:00:00 6.7 0.9 9.5 4.2 6.7 0.9 9.1 4.2 6.4 1 9.1 3.4 316 7 325 165 2.6 0 2.8 2.6 01/09/2006 16:10:00 6.7 0.7 8.4 4.9 6.7 0.7 8.4 4.9 6.6 0.8 9.1 4.2 317 6 319 165 2.4 0 2.6 2.3 01/09/2006 16:20:00 5.9 1 8.8 3.8 5.9 1 8.8 3.8 5.8 1 8.4 3.8 319 7 319 165 2.4 0 2.6 2.3 01/09/2006 16:30:00 6.1 1 8.8 3.8 6 1.2 9.1 3.4 6.1 1.2 9.1 3.8 335 13 338 165 2.4 0 2.6 2.3 01/09/2006 16:40:00 6.1 1.1 8.8 3.8 6.1 1.1 8.8 3.8 6.2 1.1 8.8 3.8 336 9 333 165 2.5 0 2.8 2.6 01/09/2006 16:50:00 6.1 0.7 9.1 4.9 6.2 0.7 8.8 4.6 6.2 0.6 9.1 4.9 341 6 336 165 2.5 0 2.6 2.6 01/09/2006 17:00:00 6.8 0.8 8.8 5.3 6.8 0.9 8.8 3.4 6.9 0.8 8.8 4.6 338 10 328 165 2.7 0 2.8 2.6 01/09/2006 17:10:00 6.9 0.7 8.4 5.3 7 0.8 8.8 4.2 6.9 0.8 8.8 5.3 338 6 343 165 2.7 0 2.8 2.6 01/09/2006 17:20:00 7 0.8 9.1 4.9 6.8 1 9.5 4.2 7.1 0.9 9.1 5.3 343 8 349 165 2.6 0.1 2.8 2.6 01/09/2006 17:30:00 6 0.6 7.2 4.2 5.5 1.2 7.6 2.3 6 0.6 7.6 4.6 349 6 0 165 2.4 0 2.6 2.3 01/09/2006 17:40:00 4.7 0.7 6.5 3 4.3 1.1 6.5 1.5 4.7 0.7 6.1 3.4 344 10 346 165 2 0.1 2.3 1.8 01/09/2006 17:50:00 3.9 0.4 4.9 2.6 3.7 0.6 5.3 1.9 3.9 0.4 4.9 2.6 346 6 334 165 1.9 0 2.3 1.8 01/09/2006 18:00:00 3.4 0.5 4.6 2.3 2.6 0.8 4.6 1.1 3.4 0.4 4.6 2.3 355 9 351 165 1.9 0 2.1 1.8 01/09/2006 18:10:00 2.8 0.8 4.6 0.4 2 0.8 4.6 0.4 2.9 0.8 4.6 0.4 8 15 22 165 2 0 2.3 1.8 01/09/2006 18:20:00 3 0.4 4.2 1.9 1.7 0.5 3.4 0.4 3.1 0.4 4.2 2.3 3 5 7 165 2.1 0 2.3 1.8 01/09/2006 18:30:00 3.5 0.4 4.6 2.6 2.6 0.7 4.2 1.1 3.4 0.3 4.6 2.6 12 7 4 165 2.1 0 2.3 2.1 01/09/2006 18:40:00 2.7 0.6 4.2 1.5 1.8 0.8 4.6 0.4 2.8 0.6 4.6 1.5 9 8 5 165 2.2 0 2.3 2.1 01/09/2006 18:50:00 2.2 0.4 3 1.1 1.6 0.5 2.6 0.4 2.3 0.5 3 0.4 11 5 7 165 2 0 2.3 1.8 01/09/2006 19:00:00 2.6 0.5 3.4 1.1 1.8 0.5 3.4 0.7 2.6 0.5 3.4 1.1 358 8 7 165 1.8 0 2.1 1.6 01/09/2006 19:10:00 2.5 0.5 3.4 1.1 0.9 0.7 2.6 0.4 2.3 0.5 3.4 0.7 355 3 357 165 1.6 0 1.6 1.4 01/09/2006 19:20:00 2.6 0.5 3.8 1.5 0.4 0 0.4 0.4 2.5 0.4 3.4 1.5 2 1 4 165 1.6 0 1.8 1.6 01/09/2006 19:30:00 3.9 0.3 4.6 3 0.4 0 0.4 0.4 3.8 0.4 4.9 3 6 1 4 165 1.7 0 1.8 1.6 01/09/2006 19:40:00 3.2 0.3 4.2 2.6 0.4 0 0.4 0.4 3.3 0.3 4.2 2.6 8 1 7 165 1.6 0 1.8 1.6 01/09/2006 19:50:00 3.1 0.2 3.4 2.6 0.4 0 0.4 0.4 3.2 0.2 3.4 2.6 10 1 10 165 1.6 0 1.8 1.4 01/09/2006 20:00:00 2.7 0.4 4.6 1.5 0.4 0 0.4 0.4 2.9 0.4 3.8 1.5 12 1 16 165 1.7 0 1.8 1.6 01/09/2006 20:10:00 4.5 1.1 7.2 2.6 3.3 1.6 6.5 0.4 4.4 1 6.8 3 48 16 54 165 2.1 0 2.3 1.8 01/09/2006 20:20:00 3.6 0.7 5.7 1.9 3.4 0.8 5.7 1.9 3.4 0.8 5.7 1.9 47 9 60 165 2 0.1 2.6 1.8 01/09/2006 20:30:00 3.9 0.7 5.7 2.3 3.9 0.8 5.7 2.3 3.6 0.7 5.3 2.3 56 8 48 165 1.8 0 1.8 1.6 01/09/2006 20:40:00 3.8 0.7 5.3 1.9 3.7 0.8 5.3 1.9 3.5 0.6 5.3 1.9 47 13 21 165 1.8 0 2.1 1.6 01/09/2006 20:50:00 3.8 0.7 6.1 2.3 3.7 0.8 6.1 2.3 3.4 0.7 5.7 1.9 46 8 48 165 1.7 0 1.8 1.6 01/09/2006 21:00:00 3.5 0.7 5.3 2.3 3.4 0.8 5.7 2.3 3.2 0.7 5.3 1.9 47 11 54 165 1.7 0 1.8 1.6 01/09/2006 21:10:00 4.4 0.6 5.7 2.6 4.4 0.7 5.7 2.6 4.1 0.7 5.3 2.3 61 6 63 165 2 0 2.3 1.8 01/09/2006 21:20:00 4.7 0.7 7.2 3.4 4.7 0.7 6.8 3 4.3 0.7 6.5 2.3 71 9 84 165 2.4 0.1 2.6 2.1 01/09/2006 21:30:00 6.2 0.5 7.2 4.9 6.2 0.5 7.6 4.9 6 0.6 7.2 4.6 86 6 77 165 2.8 0.1 3 2.6 01/09/2006 21:40:00 5.4 0.6 7.2 3.8 5.6 0.6 7.6 4.2 5.3 0.7 7.2 3.4 84 7 87 165 2.9 0 3 2.8 01/09/2006 21:50:00 5.1 0.8 6.8 3 5.4 0.8 6.8 3.4 4.8 0.7 6.5 3 93 7 91 165 3 0 3 2.8 01/09/2006 22:00:00 4.7 0.9 6.5 2.6 4.9 0.9 6.8 3 4.3 0.9 6.5 2.3 93 9 90 165 2.9 0 3 2.8 01/09/2006 22:10:00 6.8 0.5 8 5.3 7 0.5 8.4 5.7 6.5 0.7 8.4 4.6 102 6 99 165 2.9 0 3 2.8 01/09/2006 22:20:00 5.9 0.6 7.6 3.8 6.2 0.6 8 3.8 5.6 0.5 6.8 3.8 95 8 107 165 2.5 0.2 2.8 2.3 01/09/2006 22:30:00 5.2 0.4 6.1 3.8 5.4 0.4 6.5 4.2 5.1 0.4 6.1 3.8 88 5 87 165 2.3 0 2.3 2.3 01/09/2006 22:40:00 4.4 0.6 5.7 2.6 4.6 0.6 6.1 2.6 4.2 0.6 5.3 3 65 7 69 165 2.4 0 2.8 2.3 01/09/2006 22:50:00 4.5 0.6 6.1 3 4.7 0.6 6.5 3 4.2 0.6 6.1 2.6 76 6 73 165 2.7 0 2.8 2.6 01/09/2006 23:00:00 4.6 0.8 6.5 2.6 4.8 0.8 6.8 3 4.4 0.7 6.1 2.6 74 9 87 165 2.7 0 3 2.8 01/09/2006 23:10:00 6.1 0.5 7.6 4.2 6.3 0.5 8 4.2 5.9 0.6 7.2 3.8 87 4 81 165 2.7 0 2.8 2.6 01/09/2006 23:20:00 5.6 0.4 7.2 4.6 5.8 0.4 7.2 4.6 5.3 0.5 6.5 3.8 87 3 89 165 2.5 0 2.8 2.6 01/09/2006 23:30:00 5.3 0.5 6.5 3.8 5.5 0.5 6.5 3.8 5 0.5 6.1 3.4 76 7 85 165 2.9 0 3 2.8 01/09/2006 23:40:00 4.8 0.9 6.5 3 5 1 6.8 3 4.6 0.9 6.5 3 76 7 83 165 2.9 0 3 2.8 01/09/2006 23:50:00 3.7 1 5.7 1.9 3.8 1 5.7 1.9 3.6 0.9 5.3 1.5 78 9 70 165 2.8 0 3 2.8 01/10/2006 00:00:00 3 0.8 4.6 1.1 3 0.9 4.6 1.1 2.7 0.8 4.2 1.1 100 14 90 165 2.9 0 3.3 2.8 01/10/2006 00:10:00 2.5 0.7 4.6 1.1 2.6 0.7 4.9 1.1 2.2 0.7 4.2 0.7 111 13 104 165 2.9 0 3 2.8 01/10/2006 00:20:00 3.4 0.7 4.9 2.3 3.6 0.7 5.3 2.3 3.3 0.7 4.6 1.9 89 7 87 165 2.9 0 3 2.8 01/10/2006 00:30:00 3.7 0.5 4.9 2.3 3.9 0.5 4.9 2.3 3.8 0.5 4.9 1.9 84 5 78 165 2.9 0 3 2.8 01/10/2006 00:40:00 3.7 0.3 4.6 2.6 3.9 0.3 4.9 3 3.7 0.4 4.9 3 90 3 84 165 2.8 0 3 2.8 01/10/2006 00:50:00 2.6 0.6 3.4 0.7 2.8 0.6 3.8 0.7 2.6 0.5 3.8 1.5 92 7 85 165 2.9 0 3 2.8 01/10/2006 01:00:00 1.5 0.7 3 0.4 1.6 0.8 3 0.4 1.7 0.7 3 0.4 88 9 83 165 2.7 0 2.8 2.8 01/10/2006 01:10:00 3 0.5 4.2 1.5 3.2 0.5 4.6 1.9 2.9 0.5 4.2 1.9 75 5 73 165 2.7 0 3 2.6 01/10/2006 01:20:00 3.2 0.5 4.2 2.3 3.4 0.5 4.6 2.3 3 0.5 4.2 1.5 73 6 65 165 2.7 0 2.8 2.6 01/10/2006 01:30:00 2.7 0.4 3.8 1.5 2.9 0.4 3.8 1.9 2.6 0.4 3.4 1.9 74 5 76 165 2.6 0 2.8 2.6 01/10/2006 01:40:00 1.5 0.5 2.3 0.4 1.5 0.6 2.6 0.4 1.5 0.5 2.3 0.4 56 10 62 165 2.6 0 2.8 2.6 01/10/2006 01:50:00 2.2 0.5 3.4 1.1 2.1 0.5 3.4 1.1 2.2 0.4 3.4 1.1 37 7 26 165 2.6 0 2.8 2.6 01/10/2006 02:00:00 2.9 0.3 3.8 2.3 2.7 0.4 3.4 1.5 2.8 0.3 3.4 1.9 25 5 28 165 2.6 0 2.8 2.6 01/10/2006 02:10:00 2.4 0.2 3 1.9 2.1 0.3 3 1.1 2.4 0.3 3 1.9 19 3 16 165 2.6 0 2.8 2.6 01/10/2006 02:20:00 2.5 0.3 3 1.9 1.9 0.4 2.6 0.7 2.5 0.2 3 1.9 14 3 17 165 2.6 0 2.8 2.6 01/10/2006 02:30:00 2.2 0.2 2.6 1.5 1.7 0.4 2.3 0.7 2.1 0.2 2.6 1.5 15 5 10 165 2.6 0 2.8 2.6 01/10/2006 02:40:00 2.1 0.3 2.6 1.5 1.9 0.3 2.6 1.1 2.1 0.2 2.6 1.5 24 2 25 165 2.5 0 2.8 2.6 01/10/2006 02:50:00 2.4 0.5 3.4 1.5 2.2 0.4 3.4 1.5 2.2 0.5 3.4 1.1 27 4 31 165 2.5 0 2.6 2.6 01/10/2006 03:00:00 2.3 0.4 3.4 1.1 2.1 0.4 3 1.1 2.1 0.4 3 1.1 32 5 26 165 2.5 0 2.8 2.6 01/10/2006 03:10:00 0.6 0.5 2.3 0.4 0.6 0.5 2.3 0.4 0.6 0.4 1.9 0.4 87 24 50 165 2.4 0 2.8 2.3 01/10/2006 03:20:00 0.5 0.2 1.1 0.4 0.5 0.2 1.1 0.4 0.5 0.2 1.1 0.4 119 8 116 165 2.4 0 2.6 2.3 01/10/2006 03:30:00 0.4 0.1 0.7 0.4 0.4 0 0.4 0.4 0.4 0.1 0.7 0.4 102 0 102 165 2.2 0 2.3 2.3 01/10/2006 03:40:00 0.4 0 0.7 0.4 0.4 0 0.7 0.4 0.4 0 0.4 0.4 95 20 43 165 2.2 0 2.3 2.3 01/10/2006 03:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 103 2 165 165 2.2 0 2.6 2.3 01/10/2006 04:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 104 0 165 165 2.2 0 2.3 2.1 01/10/2006 04:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 104 0 165 165 2.1 0 2.3 2.1 01/10/2006 04:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 104 0 165 165 2.1 0 2.3 2.1 01/10/2006 04:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 97 10 165 165 2.1 0 2.3 2.1 01/10/2006 04:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 80 0 165 165 2.1 0 2.3 2.1 01/10/2006 04:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 80 0 165 165 2.1 0 2.3 2.1 01/10/2006 05:00:00 0.4 0.1 0.7 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 121 43 165 165 2 0 2.3 1.8 01/10/2006 05:10:00 0.4 0.1 1.1 0.4 0.4 0 0.7 0.4 0.4 0.1 1.1 0.4 173 2 172 165 1.9 0 2.1 1.8 01/10/2006 05:20:00 0.5 0.2 1.1 0.4 0.4 0.1 0.7 0.4 0.5 0.3 1.5 0.4 154 13 171 165 1.8 0 1.8 1.6 01/10/2006 05:30:00 0.4 0.1 0.7 0.4 0.4 0.1 0.7 0.4 0.4 0.1 1.1 0.4 151 9 145 165 1.6 0 1.8 1.6 01/10/2006 05:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 206 30 165 165 1.6 0 1.8 1.6 01/10/2006 05:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 227 0 165 165 1.7 0 1.8 1.6 01/10/2006 06:00:00 0.7 0.4 1.9 0.4 0.9 0.6 2.3 0.4 0.6 0.5 2.3 0.4 249 18 264 165 1.7 0 1.8 1.6 01/10/2006 06:10:00 0.6 0.4 1.9 0.4 0.7 0.5 2.3 0.4 0.8 0.5 2.3 0.4 269 4 262 165 1.7 0 1.8 1.6 01/10/2006 06:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 270 0 165 165 1.7 0 1.8 1.6 01/10/2006 06:30:00 0.4 0.1 0.7 0.4 0.4 0.1 0.7 0.4 0.4 0.1 1.1 0.4 288 9 278 165 1.9 0 1.8 1.6 01/10/2006 06:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 307 49 165 165 1.8 0 1.8 1.6 01/10/2006 06:50:00 0.9 0.4 1.5 0.4 0.8 0.4 1.5 0.4 0.9 0.3 1.5 0.4 135 3 140 165 1.6 0 1.8 1.4 01/10/2006 07:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0.1 0.7 0.4 141 15 165 165 1.6 0 1.8 1.6 01/10/2006 07:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.7 0.4 182 20 165 165 1.7 0 1.8 1.6 01/10/2006 07:20:00 1.1 0.5 1.9 0.4 1.1 0.5 1.9 0.4 0.9 0.3 1.9 0.4 303 14 295 165 1.7 0 1.8 1.6 01/10/2006 07:30:00 0.5 0.3 1.5 0.4 0.4 0.2 1.5 0.4 0.4 0.2 2.3 0.4 15 17 0 165 1.7 0 1.8 1.6 01/10/2006 07:40:00 1.2 0.4 2.3 0.4 1.2 0.4 1.9 0.4 1.3 0.4 2.3 0.4 98 6 97 165 1.7 0 1.8 1.6 01/10/2006 07:50:00 1.6 0.3 2.3 1.1 1.6 0.3 2.3 1.1 1.7 0.3 2.3 1.1 98 3 94 165 1.7 0 1.8 1.6 01/10/2006 08:00:00 1.6 0.4 3 1.1 1.6 0.4 2.6 1.1 1.6 0.4 2.6 1.1 112 4 116 165 1.7 0 1.8 1.6 01/10/2006 08:10:00 2.1 0.5 3 1.1 2.1 0.5 3 1.1 2 0.5 3 0.7 115 0 115 165 1.7 0 1.8 1.6 01/10/2006 08:20:00 2.2 0.4 3 1.1 2.2 0.5 3 0.7 2.1 0.5 3 0.7 114 0 114 165 1.6 0 1.8 1.6 01/10/2006 08:30:00 0.6 0.4 1.9 0.4 0.4 0.2 1.5 0.4 0.6 0.5 1.9 0.4 114 0 115 165 1.5 0 1.6 1.4 01/10/2006 08:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 2.3 0.4 3.8 1.1 114 0 165 165 1.5 0 1.6 1.4 01/10/2006 08:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 2.6 0.5 3.4 1.5 114 0 165 165 1.6 0 1.6 1.6 01/10/2006 09:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 1.9 0.4 3 1.1 114 0 165 165 1.6 0 1.6 1.6 01/10/2006 09:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 2.4 0.5 4.2 1.5 114 0 165 165 1.6 0 1.8 1.6 01/10/2006 09:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 2.9 0.7 4.9 1.5 114 0 165 165 1.5 0 1.8 1.6 01/10/2006 09:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 1 0.7 2.6 0.4 114 0 165 165 1.5 0 1.8 1.4 01/10/2006 09:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 115 0 165 165 1.5 0 1.6 1.4 01/10/2006 09:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 115 0 165 165 1.5 0 1.6 1.4 01/10/2006 10:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 115 0 165 165 1.5 0 1.6 1.4 01/10/2006 10:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 115 0 165 165 1.6 0 1.6 1.4 01/10/2006 10:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 117 2 165 165 1.7 0 1.8 1.6 01/10/2006 10:30:00 0.5 0.2 1.1 0.4 0.4 0 0.4 0.4 0.4 0 0.7 0.4 123 4 121 165 1.7 0 1.8 1.6 01/10/2006 10:40:00 1.2 0.7 3 0.4 0.9 0.9 3 0.4 0.4 0 0.7 0.4 136 5 133 165 1.7 0 1.8 1.6 01/10/2006 10:50:00 2.2 0.5 3.8 1.1 2.8 0.5 4.9 1.9 2.7 0.7 3.8 0.4 137 7 121 165 1.7 0 1.8 1.6 01/10/2006 11:00:00 1.4 0.8 3 0.4 2.1 0.8 3.8 0.4 2 0.8 3.4 0.4 145 9 147 165 1.7 0 1.8 1.6 01/10/2006 11:10:00 2.5 0.4 3.8 1.5 3.1 0.3 4.2 2.3 3.1 0.3 3.8 1.9 140 5 128 165 1.7 0 1.8 1.6 01/10/2006 11:20:00 2.5 0.5 4.2 1.1 3.1 0.4 4.6 1.9 3.2 0.5 4.6 1.9 137 7 135 165 1.8 0 1.8 1.6 01/10/2006 11:30:00 2.3 0.3 3 1.9 2.9 0.3 3.8 2.3 3.1 0.3 3.8 1.9 142 6 130 165 1.8 0 1.8 1.8 01/10/2006 11:40:00 1.2 0.4 2.3 0.4 2.6 0.2 3 1.9 2.7 0.3 3.4 1.9 140 8 151 165 1.8 0 1.8 1.6 01/10/2006 11:50:00 1.9 1.2 4.6 0.4 3.2 0.8 4.9 2.3 3.4 0.8 5.3 2.3 144 6 147 165 1.8 0 1.8 1.8 01/10/2006 12:00:00 3.1 0.5 4.2 1.9 3.8 0.4 4.6 3 4.1 0.5 5.3 3 148 3 152 165 1.8 0 2.1 1.8 01/10/2006 12:10:00 1.7 1.1 4.6 0.4 4.1 0.7 6.1 3 4.3 0.6 6.1 3.4 147 5 147 165 1.7 0 1.8 1.6 01/10/2006 12:20:00 4.1 0.5 5.3 2.3 4.9 0.7 6.5 3 5.1 0.6 6.5 3.4 142 2 143 165 1.5 0.1 1.8 1.4 01/10/2006 12:30:00 3.1 1 4.6 0.4 3.6 0.7 4.9 1.9 4.1 0.7 5.3 2.3 143 0 143 165 1.5 0 1.6 1.4 01/10/2006 12:40:00 0.4 0 0.4 0.4 0.9 0.6 2.3 0.4 1.5 0.8 3 0.4 145 1 165 165 1.6 0 1.8 1.4 01/10/2006 12:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.5 0.3 1.9 0.4 144 2 165 165 1.7 0 1.8 1.6 01/10/2006 13:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.5 0.3 1.5 0.4 141 2 165 165 1.7 0 1.8 1.6 01/10/2006 13:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0.1 1.1 0.4 105 51 165 165 1.7 0 1.8 1.6 01/10/2006 13:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0.1 0.7 0.4 357 1 165 165 1.8 0 1.8 1.6 01/10/2006 13:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0.1 1.1 0.4 357 0 165 165 2.4 0.3 3 1.8 01/10/2006 13:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 358 1 165 165 3.1 0.1 3.5 2.8 01/10/2006 13:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 359 0 165 165 4 0.2 4.3 3.5 01/10/2006 14:00:00 0.4 0.2 1.5 0.4 0.4 0.1 1.1 0.4 0.4 0 0.7 0.4 15 36 150 165 3.9 0 4.3 3.8 01/10/2006 14:10:00 0.4 0.1 1.1 0.4 0.4 0.1 1.1 0.4 0.4 0 0.7 0.4 78 13 98 165 3.4 0.2 4 3 01/10/2006 14:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 51 14 165 165 3.3 0 3.5 3.3 01/10/2006 14:30:00 0.5 0.3 1.5 0.4 0.4 0.2 1.1 0.4 0.6 0.3 1.5 0.4 49 20 45 165 2.9 0.2 3.5 2.6 01/10/2006 14:40:00 0.8 0.4 1.5 0.4 0.8 0.4 1.9 0.4 1.3 0.4 2.3 0.4 44 1 44 165 2.6 0 2.8 2.3 01/10/2006 14:50:00 1.7 0.4 2.6 0.7 1.9 0.4 2.6 1.1 2 0.4 3 1.1 35 5 34 165 2.5 0.1 2.8 2.3 01/10/2006 15:00:00 2.6 0.2 3 1.9 2.7 0.2 3 1.9 2.9 0.3 3.4 1.5 28 5 26 165 2 0.2 2.3 1.8 01/10/2006 15:10:00 2.8 0.2 3.4 2.6 1.9 0.5 3 0.7 3.1 0.2 3.8 2.6 9 6 0 165 1.7 0 1.8 1.6 01/10/2006 15:20:00 2.9 0.4 4.2 1.9 2.5 0.9 4.2 1.1 3.1 0.3 4.2 2.6 352 6 345 165 1.7 0 1.8 1.6 01/10/2006 15:30:00 3.4 0.2 3.8 2.6 3.5 0.3 4.2 1.9 3.5 0.2 4.2 3 338 5 344 165 1.6 0.1 1.8 1.4 01/10/2006 15:40:00 2.9 0.3 3.8 1.9 3 0.3 3.8 2.3 3 0.3 3.8 2.3 333 5 334 165 1.5 0.1 1.8 1.4 01/10/2006 15:50:00 2.5 0.4 3.4 1.1 2.7 0.4 3.4 1.5 2.8 0.4 3.4 1.9 338 6 343 165 1.9 0 1.8 1.8 01/10/2006 16:00:00 3 0.3 3.8 2.3 3 0.5 4.2 1.5 3.1 0.3 3.8 2.3 345 5 336 165 1.7 0 2.1 1.6 01/10/2006 16:10:00 3.5 0.4 4.2 2.6 3.3 0.6 4.6 1.5 3.6 0.3 4.6 2.6 347 5 334 165 1.3 0.1 1.8 0.9 01/10/2006 16:20:00 4 0.5 5.3 3 3.6 0.8 5.3 1.5 4 0.4 5.3 3 345 9 333 165 0.8 0.1 1.4 0.7 01/10/2006 16:30:00 3.9 0.7 5.7 2.3 3.6 0.9 5.7 1.9 3.8 0.6 5.3 1.9 343 10 330 165 0.7 0 0.9 0.7 01/10/2006 16:40:00 4.9 0.7 6.8 3.4 4.8 0.8 6.8 3 4.6 0.7 6.5 3 339 7 344 165 0.6 0 0.9 0.7 01/10/2006 16:50:00 4.9 0.6 6.8 3.4 4.8 0.7 6.8 3 4.6 0.5 6.1 3.4 338 9 329 165 0.6 0 0.9 0.7 01/10/2006 17:00:00 5.6 0.8 7.2 3.8 5.5 0.9 7.6 2.3 5.3 0.7 7.2 3.8 340 8 345 165 0.8 0 0.9 0.7 01/10/2006 17:10:00 5.6 0.7 7.2 3.8 5 1 6.8 2.6 5.2 0.7 6.8 3 349 7 351 165 0.8 0 0.9 0.7 01/10/2006 17:20:00 5.8 0.7 7.2 4.2 5.7 0.8 7.6 3.4 5.2 0.7 6.8 3.4 343 7 343 165 0.8 0 0.9 0.7 01/10/2006 17:30:00 6.1 0.9 8.4 4.2 6.1 0.8 8 4.2 5.7 0.8 7.6 4.2 338 6 338 165 0.7 0 0.9 0.7 01/10/2006 17:40:00 6.9 1 9.9 4.2 6.8 1.1 9.5 3.8 6.8 1 9.9 4.6 336 10 339 165 0.8 0 1.1 0.7 01/10/2006 17:50:00 6.6 1 9.1 4.2 6.5 1 9.5 3.8 6.5 1 9.1 4.2 328 11 342 165 0.8 0 1.1 0.9 01/10/2006 18:00:00 6.7 0.6 9.1 4.9 6.5 0.6 8.8 4.9 6.6 0.6 8 4.9 332 9 348 165 0.8 0 0.9 0.7 01/10/2006 18:10:00 6.9 0.6 9.1 5.3 6.9 0.6 8.8 5.3 6.8 0.7 8.4 4.9 327 10 311 165 0.8 0 0.9 0.7 01/10/2006 18:20:00 7.7 0.7 9.1 5.7 7.6 0.7 9.1 5.3 6.6 0.8 8.4 3.8 307 3 307 165 1.2 0.2 1.6 0.7 01/10/2006 18:30:00 7.8 0.8 10.3 5.7 7.6 0.8 9.9 5.7 6.5 1.2 9.9 2.6 308 0 308 165 0.8 0.1 1.4 0.7 01/10/2006 18:40:00 7.9 0.9 9.9 4.9 7.8 0.9 9.9 4.6 6.3 1 9.1 3.8 308 0 308 165 0.7 0 0.9 0.7 01/10/2006 18:50:00 7.6 1.2 10.7 3.8 7.5 1.1 10.7 3.4 5.4 1.5 8.8 0.4 308 0 308 165 0.8 0 0.9 0.7 01/10/2006 19:00:00 8.4 1.2 11.1 5.3 8.3 1.2 10.7 4.9 6.2 1.3 9.9 2.3 308 0 308 165 0.8 0 0.9 0.7 01/10/2006 19:10:00 8.8 1.1 11.1 6.1 8.6 1.1 11.1 5.7 6 1.1 9.1 1.5 308 0 308 165 0.8 0 0.9 0.9 01/10/2006 19:20:00 7.4 1.3 10.3 3.8 7.4 1.2 9.9 3.8 5.2 1.4 8 0.4 308 0 308 165 0.8 0 0.9 0.7 01/10/2006 19:30:00 7.1 1.2 9.9 3.8 7.1 1.1 9.9 4.2 5.7 1.2 8 1.9 308 0 308 165 0.7 0 0.9 0.7 01/10/2006 19:40:00 8.6 1.3 11.5 4.2 8.5 1.2 11.1 4.9 5.8 1.4 8.8 1.5 308 0 308 165 0.5 0 0.7 0.4 01/10/2006 19:50:00 9.7 1.2 12.6 6.1 9.5 1.2 12.2 5.7 7.2 1.3 10.7 3.8 308 0 308 165 0.6 0 0.9 0.7 01/10/2006 20:00:00 10.2 0.9 12.2 7.2 10.1 0.9 12.2 7.2 7.8 1 10.3 4.6 308 0 308 165 0.7 0 0.9 0.7 01/10/2006 20:10:00 11.3 1 14.1 8.8 11.2 1 13.7 8.4 8.6 1.2 11.8 5.7 308 0 308 165 0.7 0 0.9 0.7 01/10/2006 20:20:00 12.8 1 16.1 9.5 12.7 1 15.6 9.5 8.8 1.1 12.6 6.1 308 0 308 165 0.7 0 0.9 0.7 01/10/2006 20:30:00 13 1.1 16.4 9.1 12.8 1 16.1 9.5 9.5 1.3 13.3 6.5 307 0 308 165 0.5 0 0.9 0.4 01/10/2006 20:40:00 12.9 1.2 16.1 9.9 12.7 1.2 15.6 9.5 9.4 1.3 13.3 6.5 307 0 307 165 0.6 0 0.9 0.4 01/10/2006 20:50:00 13 1.1 15.6 8.8 12.9 1.1 15.3 9.1 9.5 1.2 13.3 6.5 306 0 307 165 0.7 0 0.9 0.7 01/10/2006 21:00:00 12.4 1.3 15.6 8 12.3 1.3 15.3 8.4 9.1 1.2 12.6 6.5 306 0 307 165 0.6 0 0.9 0.7 01/10/2006 21:10:00 12.8 1.3 16.4 9.1 12.6 1.3 16.1 9.1 9.7 1.5 16.1 6.5 306 0 307 165 0.6 0 0.7 0.7 01/10/2006 21:20:00 11.7 1.6 15.3 6.8 11.5 1.5 14.9 6.8 9.2 1.5 13 4.6 305 0 305 165 0.5 0 0.7 0.4 01/10/2006 21:30:00 12.5 1.4 16.4 8.4 12.3 1.3 16.4 8.4 9.9 1.5 14.5 5.7 305 0 305 165 0.5 0 0.7 0.4 01/10/2006 21:40:00 12.9 1.2 16.1 8.8 12.6 1.1 16.1 8.8 10 1.2 14.9 7.2 305 0 305 165 0.5 0 0.9 0.4 01/10/2006 21:50:00 14.5 1.3 17.2 9.1 14.3 1.3 16.8 9.1 10.6 1.3 14.1 6.5 305 0 305 165 0.5 0 0.7 0.4 01/10/2006 22:00:00 13.7 1.3 16.8 9.1 13.5 1.2 16.4 9.1 10.6 1.2 13.7 7.2 305 0 304 165 0.5 0 0.7 0.2 01/10/2006 22:10:00 13.9 1.3 17.6 10.3 13.8 1.3 17.6 10.3 10.7 1.3 14.5 7.6 304 0 304 165 0.5 0 0.7 0.4 01/10/2006 22:20:00 13.7 1.4 16.4 9.5 13.5 1.3 16.8 9.1 10.3 1.3 13.7 6.8 304 0 304 165 0.4 0 0.7 0.2 01/10/2006 22:30:00 14 1.1 16.4 11.1 13.9 1 16.1 11.1 11.3 1.2 16.1 8 304 0 304 165 0.3 0 0.7 0.2 01/10/2006 22:40:00 14.4 1.1 16.8 9.9 14.3 1.1 16.4 9.9 11.8 1.1 15.3 7.6 304 0 304 165 0.3 0 0.4 0.2 01/10/2006 22:50:00 13.1 1.3 16.1 9.5 12.9 1.3 15.6 8.8 10.2 1 13.3 6.1 304 0 304 165 0.2 0 0.2 0.2 01/10/2006 23:00:00 12.8 1.2 16.8 9.9 12.7 1.2 16.8 9.9 9.9 1.2 13.7 7.2 304 0 304 165 0.2 0 0.2 0.2 01/10/2006 23:10:00 13.6 1 15.6 10.7 13.5 1 15.6 10.7 10.7 1.1 14.1 8 304 0 304 165 0.2 0 0.4 0.2 01/10/2006 23:20:00 13.6 1.2 16.1 9.5 13.6 1.2 16.1 9.5 10.9 1.1 14.1 8.4 304 0 304 165 0.2 0 0.2 0.2 01/10/2006 23:30:00 14.2 1.2 16.8 10.7 14.1 1.2 16.4 10.3 11.6 1.2 14.9 8.4 304 0 304 165 0.1 0 0.2 0.2 01/10/2006 23:40:00 14.9 1.1 17.6 11.5 14.8 1.1 17.6 11.5 11.9 1.1 14.9 8 304 0 304 165 0.1 0 0.2 0.2 01/10/2006 23:50:00 15.7 0.8 17.9 13 15.7 0.8 17.6 12.6 13 1.1 18.3 10.3 304 0 304 165 0.2 0 0.2 0.2 01/11/2006 00:00:00 15.9 1 17.9 12.2 15.8 1 17.6 11.8 13 1.3 17.9 10.3 304 0 304 165 0.2 0 0.4 0.2 01/11/2006 00:10:00 15.6 1.2 19.1 11.8 15.6 1.2 18.7 12.2 13.7 1.3 16.8 9.9 305 0 305 165 0.2 0 0.4 0.2 01/11/2006 00:20:00 15.7 1.1 17.9 11.5 15.6 1.2 18.3 11.5 13.3 1.4 16.8 9.9 305 0 305 165 0.2 0 0.2 0.2 01/11/2006 00:30:00 16 1.1 18.3 12.2 15.9 1.1 17.9 11.8 14.3 1.3 17.6 9.5 305 0 305 165 0.2 0 0.2 0.2 01/11/2006 00:40:00 15.6 1.2 17.9 9.5 15.6 1.2 17.9 9.9 13.9 1.3 16.8 9.5 305 0 305 165 0.2 0 0.2 0.2 01/11/2006 00:50:00 15 1.2 17.6 11.1 15 1.2 17.2 11.1 14.1 1.4 17.2 9.1 305 0 305 165 0.2 0 0.4 0.2 01/11/2006 01:00:00 14.9 1 17.2 11.1 14.8 1 17.2 11.1 13.8 1 16.4 10.7 305 0 305 165 0.2 0 0.2 0.2 01/11/2006 01:10:00 15.6 1 17.9 13 15.5 1 17.9 13 13.7 1.3 17.6 9.5 306 0 306 165 0.2 0 0.2 0.2 01/11/2006 01:20:00 15.8 1 17.9 12.6 15.7 1 17.9 11.8 13.5 1.2 16.4 9.1 306 0 306 165 0.3 0 0.7 0.2 01/11/2006 01:30:00 15.1 1.2 17.2 11.8 15 1.2 17.2 11.5 13.3 1.2 16.4 9.1 306 0 306 165 0.3 0 0.7 0.2 01/11/2006 01:40:00 14.5 0.6 16.4 13 14.5 0.6 16.4 12.6 12.9 1 14.9 9.9 307 0 307 165 0.2 0 0.4 0.2 01/11/2006 01:50:00 14.1 1.1 17.9 10.7 14.1 1.1 17.6 11.1 11.6 1.4 16.8 8 307 0 307 165 0.2 0 0.7 0.2 01/11/2006 02:00:00 13.5 1.3 17.2 9.1 13.4 1.3 17.2 8.8 11.5 1.4 15.3 7.6 307 0 307 165 0.2 0 0.4 0.2 01/11/2006 02:10:00 11.8 1 16.1 8.4 11.7 1 15.6 8.4 10 1.1 15.3 6.8 308 0 308 165 0.2 0 0.7 0.2 01/11/2006 02:20:00 10.9 1.2 14.9 8 10.8 1.3 15.6 8 9.2 1.2 13 6.1 308 0 308 165 0.2 0 0.7 0.2 01/11/2006 02:30:00 10.3 1.4 15.6 6.8 10.2 1.4 15.6 7.2 9.1 1.5 14.5 5.3 308 0 308 165 0.4 0 0.7 0.2 01/11/2006 02:40:00 11 1.2 14.9 7.2 10.9 1.1 14.5 7.2 8.6 1.1 11.8 5.3 308 0 308 165 0.3 0 0.7 0.2 01/11/2006 02:50:00 11.7 1.1 14.1 8.4 11.5 1 14.1 8.4 9.3 1.2 12.2 5.7 308 0 308 165 0.2 0 0.2 0.2 01/11/2006 03:00:00 9.3 1.1 11.8 6.1 9.3 1.1 11.8 6.5 8.2 1.2 11.1 4.9 308 0 308 165 0.1 0 0.2 -0.1 01/11/2006 03:10:00 10.1 1.1 13 7.2 10 1 12.6 7.2 8.7 1.2 12.2 5.3 308 0 308 165 0.2 0 0.2 0.2 01/11/2006 03:20:00 10.7 1.4 13.7 6.5 10.7 1.3 13.3 6.5 9.1 1.2 12.2 5.3 308 0 308 165 0.1 0 0.2 -0.1 01/11/2006 03:30:00 10.8 1.3 14.1 6.8 10.6 1.4 14.5 5.7 9.2 1.3 12.6 6.1 308 0 309 165 0.2 0 0.2 -0.1 01/11/2006 03:40:00 11 1.1 13.7 7.6 10.8 1.1 13.7 7.6 9.2 1.1 12.2 6.1 308 0 308 165 0.1 0 0.2 -0.1 01/11/2006 03:50:00 10.5 1.6 13.7 6.5 10.4 1.5 13.3 6.1 9.2 1.7 13.3 5.3 308 4 296 165 0.1 0 0.2 -0.1 01/11/2006 04:00:00 11.5 1.4 16.1 8 11.4 1.5 16.4 8 10.5 1.4 15.6 6.5 315 7 328 165 0.2 0 0.2 0.2 01/11/2006 04:10:00 10.5 1.7 16.8 6.5 10.3 1.7 16.4 6.5 9.9 1.7 15.6 6.1 329 12 326 165 0.4 0 0.7 0.2 01/11/2006 04:20:00 9.2 1.4 13.3 4.6 9.2 1.4 13.7 5.3 8.7 1.5 13 4.9 329 10 333 165 0.6 0 0.9 0.4 01/11/2006 04:30:00 10.6 1.1 13.7 7.6 10.4 1.2 14.1 6.8 9.8 1.3 14.5 6.5 324 9 327 165 0.7 0.1 0.9 0.7 01/11/2006 04:40:00 11 1.3 15.3 7.2 10.8 1.4 15.6 7.2 10.4 1.5 14.5 6.8 332 8 341 165 0.8 0 0.9 0.7 01/11/2006 04:50:00 9.7 1.6 14.1 5.7 9.4 1.7 14.5 5.3 9.5 1.9 14.1 4.9 341 6 343 165 0.9 0 1.1 0.9 01/11/2006 05:00:00 11.3 2 16.4 7.2 11.2 2.1 16.4 6.1 10.9 2 15.3 6.5 334 7 337 165 0.8 0 1.1 0.9 01/11/2006 05:10:00 11.9 1.6 16.1 8 11.7 1.6 16.1 7.6 11.7 1.7 15.6 7.2 333 5 326 165 0.8 0 0.9 0.7 01/11/2006 05:20:00 9.8 1.3 14.1 6.1 9.6 1.4 14.1 5.7 9.5 1.5 14.1 6.5 339 1 339 165 0.7 0.1 0.9 0.2 01/11/2006 05:30:00 10.4 1.7 14.5 5.7 10.3 1.8 14.5 4.9 10.1 1.7 14.1 5.3 332 5 336 165 0.5 0 0.9 0.2 01/11/2006 05:40:00 9 2.2 15.3 4.6 8.9 2.2 16.4 4.6 8.1 2.6 15.3 2.6 318 6 328 165 0.6 0.2 0.9 0.2 01/11/2006 05:50:00 7.1 1.2 11.1 4.2 7.1 1.2 11.5 3.8 6.3 1.3 11.5 2.3 316 1 315 165 0.5 0.1 0.9 0.2 01/11/2006 06:00:00 7.2 1.3 11.1 3.8 7.2 1.3 11.5 3.8 6.8 1.5 10.3 3.8 322 4 317 165 0.7 0 0.9 0.7 01/11/2006 06:10:00 7.6 1.7 12.6 4.6 7.6 1.7 12.2 4.6 7.1 1.7 11.8 3.4 329 2 328 165 0.7 0 0.9 0.7 01/11/2006 06:20:00 8.3 1.4 13.3 5.7 8.3 1.5 12.6 4.6 8 1.3 12.2 5.3 333 4 334 165 0.7 0 0.9 0.7 01/11/2006 06:30:00 7.4 1 9.5 4.6 7.3 1 9.5 4.6 6.5 1 9.1 3.8 327 0 328 165 0.4 0.1 0.7 0.2 01/11/2006 06:40:00 7.7 1 9.9 5.3 7.6 0.9 9.9 5.7 7 1 9.9 4.2 325 0 325 165 0.2 0 0.4 0.2 01/11/2006 06:50:00 8.8 0.8 10.3 6.1 8.7 0.7 10.3 6.5 7.9 1 10.3 4.9 323 1 323 165 0.2 0 0.4 -0.1 01/11/2006 07:00:00 8.8 0.9 10.7 6.1 8.7 0.9 10.3 6.1 8.3 1 10.3 5.3 322 0 322 165 0.1 0 0.2 -0.1 01/11/2006 07:10:00 9 1.1 11.8 6.5 8.9 1.2 11.8 6.1 8.6 1.1 11.5 6.1 324 3 322 165 0.2 0 0.4 -0.1 01/11/2006 07:20:00 8.5 1.2 12.6 5.7 8.3 1.3 12.6 4.9 8 1.1 11.5 5.3 331 0 332 165 0.4 0 0.7 0.2 01/11/2006 07:30:00 10.2 1.2 13.3 6.5 10.1 1.3 13.3 6.5 9.7 1.3 13 6.1 337 5 339 165 0.8 0.1 1.1 0.4 01/11/2006 07:40:00 9 1.1 11.8 5.3 8.9 1.2 12.2 5.3 8.5 1.3 11.1 4.6 343 10 350 165 0.9 0 1.1 0.9 01/11/2006 07:50:00 8.6 1.4 12.6 4.6 8.4 1.5 12.6 4.2 8.1 1.4 12.2 4.9 332 7 332 165 0.9 0 1.1 0.9 01/11/2006 08:00:00 7.9 0.8 10.3 5.7 7.8 0.9 10.7 5.7 7.3 0.9 10.3 4.6 331 0 331 165 0.4 0.2 0.9 0.2 01/11/2006 08:10:00 8.2 1.2 11.5 4.9 8.2 1.2 11.5 5.3 7.6 1.2 10.7 4.6 330 1 328 165 0 0 0.2 -0.1 01/11/2006 08:20:00 9.6 1.2 12.2 6.5 9.5 1.1 12.2 6.8 8.2 1.1 11.1 5.3 319 8 312 165 -0.1 0 0.2 -0.1 01/11/2006 08:30:00 10.4 1.2 14.5 7.2 10.3 1.2 14.1 7.2 8.5 1.3 11.8 5.3 312 3 310 165 0.1 0 0.2 -0.1 01/11/2006 08:40:00 10.3 1.3 14.5 6.1 10.1 1.3 14.1 6.1 8.2 1.2 11.1 4.9 309 0 308 165 -0.2 0 0.2 -0.3 01/11/2006 08:50:00 9.4 1.3 12.2 6.1 9.3 1.2 12.2 6.1 7.6 1.3 10.7 2.3 309 1 308 165 -0.1 0 -0.1 -0.3 01/11/2006 09:00:00 9.4 1.4 13.3 4.9 9.4 1.3 13.3 5.7 7.7 1.3 11.5 3.4 308 0 308 165 -0.1 0 0.2 -0.3 01/11/2006 09:10:00 8.2 1.4 12.2 5.3 8.1 1.3 11.5 4.9 6.4 1.5 11.1 1.1 307 0 307 165 -0.2 0.1 0.2 -0.3 01/11/2006 09:20:00 8.9 1.4 11.8 5.7 8.8 1.4 11.8 5.7 7.5 1.3 10.7 4.2 307 0 307 165 -0.3 0 -0.1 -0.3 01/11/2006 09:30:00 10.4 1 12.6 6.8 10.3 1.1 12.2 5.7 9.2 1 11.8 6.1 308 0 308 165 -0.3 0 -0.1 -0.3 01/11/2006 09:40:00 11.2 1 13.7 8 11.2 1 13.7 8 10.2 1.1 12.6 6.8 308 0 309 165 -0.1 0 0.2 -0.1 01/11/2006 09:50:00 12.6 0.8 14.5 9.5 12.5 0.8 14.1 9.5 10.9 0.9 13.7 6.5 309 0 309 165 -0.1 0 -0.1 -0.3 01/11/2006 10:00:00 11.5 0.9 13.7 8.8 11.4 0.9 13.7 8.4 9.8 1.1 13.7 7.2 309 0 309 165 -0.1 0 -0.1 -0.1 01/11/2006 10:10:00 10.4 1.3 12.6 6.8 10.3 1.3 12.6 6.8 8.8 1.2 11.5 5.7 309 0 309 165 0 0 0.2 -0.1 01/11/2006 10:20:00 7.7 1 10.3 4.6 7.6 1 10.3 4.6 7.4 0.9 9.9 4.9 312 1 311 165 0.1 0 0.2 -0.1 01/11/2006 10:30:00 6 1 8.4 3.4 6 1 8.8 3.4 5.8 0.8 8 3.8 317 4 313 165 0.3 0 0.7 0.2 01/11/2006 10:40:00 4.7 1.3 8.4 0.4 4.7 1.3 8.4 1.1 4.5 1.2 7.6 1.5 320 0 321 165 0.6 0 0.9 0.7 01/11/2006 10:50:00 4.6 1.5 8.4 1.5 4.6 1.4 8.4 1.1 3.6 1.3 6.8 0.4 309 5 304 165 0.8 0 0.9 0.7 01/11/2006 11:00:00 5.2 1.7 8.8 0.4 5.2 1.7 8.8 0.7 3.9 1.5 8 0.4 305 1 304 165 0.6 0 0.9 0.7 01/11/2006 11:10:00 6.9 2.1 11.8 2.6 6.8 2.2 12.2 1.5 6 2.3 10.7 1.1 328 11 339 165 0.8 0 0.9 0.7 01/11/2006 11:20:00 9.2 1.2 12.2 6.5 9.1 1.3 12.6 6.5 8.6 1.2 11.8 6.1 330 13 341 165 0.9 0 1.1 0.7 01/11/2006 11:30:00 7.4 1.2 9.9 4.2 7.4 1.2 10.3 4.2 6.6 1.1 9.1 3.8 314 1 315 165 0.5 0 0.7 0.2 01/11/2006 11:40:00 7.3 1.2 11.1 4.6 7.2 1.2 11.5 4.2 6.6 1.2 10.7 3.4 318 14 338 165 0.6 0.1 0.9 0.2 01/11/2006 11:50:00 10.2 1.3 13.3 6.5 10 1.5 13.3 6.1 9.6 1.5 13 6.1 341 7 347 165 1.1 0.1 1.4 0.9 01/11/2006 12:00:00 10.2 1.3 13.3 6.8 10.3 1.4 13 6.8 9.7 1.3 13 6.5 341 6 339 165 1.4 0 1.6 1.4 01/11/2006 12:10:00 11.1 0.9 13.7 8.4 11.1 1 14.1 6.5 10.4 1.3 13.7 6.8 339 5 339 165 1.4 0 1.6 1.4 01/11/2006 12:20:00 8.4 1.7 13 3.8 7.9 1.7 12.6 4.2 7.7 1.7 12.6 3.8 342 10 348 165 1.5 0 1.6 1.4 01/11/2006 12:30:00 6.5 1.1 9.5 3.8 6.3 1.1 9.5 3.4 5.9 1.1 8.8 2.3 333 11 351 165 1.6 0 1.8 1.4 01/11/2006 12:40:00 5.7 1.2 8.4 3 5.2 1.1 8.4 1.9 5.4 1.2 8.4 3 343 8 353 165 1.6 0 1.6 1.4 01/11/2006 12:50:00 6.2 1.2 9.1 3.4 5.2 1.3 9.5 2.3 5.6 1.1 8.8 3.4 354 9 356 165 1.7 0 1.8 1.6 01/11/2006 13:00:00 8.4 1.3 12.2 5.7 8.1 1.7 12.2 4.6 7.7 1.3 11.8 4.6 344 8 340 165 1.6 0 1.8 1.6 01/11/2006 13:10:00 8.4 1.3 11.1 4.9 8.2 1.3 11.5 4.6 7.7 1.5 11.1 4.6 337 9 323 165 1.3 0.1 1.6 1.1 01/11/2006 13:20:00 7.2 1.3 10.3 3.8 6.7 1.2 10.7 3.8 6.6 1.3 10.7 3.4 341 7 347 165 1.2 0 1.4 1.1 01/11/2006 13:30:00 9.9 1 11.8 7.2 9.9 1.2 12.2 5.7 8.9 1 11.1 5.7 347 0 347 165 1.3 0 1.6 1.4 01/11/2006 13:40:00 10.3 0.8 12.2 8 10.4 0.9 12.2 8 10.1 0.9 12.6 8 343 2 346 165 1.2 0 1.4 1.1 01/11/2006 13:50:00 8.9 1 11.8 6.8 8.6 1.3 12.2 4.2 9 1.1 12.6 6.5 343 4 354 165 1.2 0 1.4 1.1 01/11/2006 14:00:00 8.5 1.1 10.7 4.2 7.2 1.5 11.1 3.8 8.4 1 11.5 5.7 350 4 351 165 1.4 0 1.4 1.4 01/11/2006 14:10:00 8.5 0.9 11.1 6.5 8.5 1 11.5 5.3 8.3 1.1 11.5 5.3 334 7 340 165 1.2 0.1 1.4 0.9 01/11/2006 14:20:00 8.5 1 10.7 6.1 8.4 0.9 10.7 6.1 7.7 0.8 9.5 5.7 321 4 318 165 0.9 0 1.1 0.9 01/11/2006 14:30:00 9.7 0.8 12.6 7.2 9.6 0.8 12.2 7.6 8.1 0.9 11.1 4.9 314 2 309 165 0.7 0 0.9 0.7 01/11/2006 14:40:00 10.2 0.8 12.6 7.6 10.2 0.8 12.6 7.6 9.2 0.9 11.8 6.5 314 4 309 165 0.5 0 0.7 0.4 01/11/2006 14:50:00 9.5 0.8 12.2 7.2 9.5 0.8 12.6 7.2 8.2 1 10.7 5.3 314 0 314 165 0.5 0 0.7 0.4 01/11/2006 15:00:00 8.2 1.3 10.7 3.8 8.1 1.2 10.3 4.2 6.8 1.1 9.5 3.4 306 5 303 165 0.7 0 0.9 0.7 01/11/2006 15:10:00 6.7 0.8 8.8 4.2 6.6 0.8 8.8 4.2 6.4 0.8 8 4.6 319 4 320 165 0.7 0 0.9 0.7 01/11/2006 15:20:00 7.8 1.2 10.3 4.6 7.7 1.2 10.3 4.6 7.6 1.4 11.5 4.6 327 6 335 165 0.8 0 0.9 0.7 01/11/2006 15:30:00 7.5 1.1 11.1 4.9 7.4 1.1 11.5 4.2 7.2 1.1 11.1 4.2 328 11 344 165 0.9 0 1.1 0.9 01/11/2006 15:40:00 6.8 0.9 9.5 4.9 6.7 0.9 9.1 4.6 6.6 0.8 8.8 4.2 325 0 325 165 0.7 0 0.9 0.7 01/11/2006 15:50:00 6.4 0.9 9.1 4.6 6.3 1 9.5 4.6 6.1 1 8.8 4.2 325 3 325 165 0.7 0 0.9 0.7 01/11/2006 16:00:00 7.3 0.9 9.9 4.9 7.2 1 10.3 3.4 6.9 1 10.3 4.6 334 7 346 165 0.8 0 1.1 0.7 01/11/2006 16:10:00 7.5 1 10.3 4.9 7.1 1.1 10.3 4.6 7.1 1.3 10.3 4.2 338 7 349 165 0.9 0 1.1 0.9 01/11/2006 16:20:00 8 1 9.9 5.7 7.9 0.9 9.5 5.7 7.3 1 9.5 4.9 336 2 336 165 1.1 0 1.4 0.9 01/11/2006 16:30:00 8 0.9 10.3 5.3 8 0.9 10.3 4.6 7 1.1 9.1 3.8 338 3 338 165 0.9 0 1.1 0.9 01/11/2006 16:40:00 9 1.2 11.8 5.7 8.9 1.3 11.8 4.9 8.6 1.5 11.8 4.9 338 5 334 165 0.8 0 1.1 0.9 01/11/2006 16:50:00 9.8 1 12.2 6.5 9.7 1.2 13 5.7 9.5 1.1 12.6 6.1 339 4 338 165 0.8 0 0.9 0.7 01/11/2006 17:00:00 9.1 0.8 11.1 6.8 9.1 1 11.1 5.3 8.6 1 11.1 6.1 338 4 341 165 0.8 0 0.9 0.7 01/11/2006 17:10:00 7.5 0.8 9.5 4.6 7.3 1.1 9.9 3.4 7.1 0.9 9.1 4.6 340 3 340 165 0.8 0 1.1 0.9 01/11/2006 17:20:00 7.9 1.1 10.3 5.3 7.4 1.4 10.3 4.2 7.9 1.1 11.1 5.3 346 5 352 165 1 0 1.4 0.9 01/11/2006 17:30:00 7.4 1.4 12.6 4.9 6.9 1.7 11.1 3.4 7.2 1.6 12.6 4.2 342 8 358 165 1.1 0 1.4 0.9 01/11/2006 17:40:00 6.4 1.2 9.5 3.4 5.5 1.3 9.9 3 6.2 1.2 9.1 2.6 349 8 351 165 1.1 0 1.4 1.1 01/11/2006 17:50:00 7.2 1.1 9.9 3.8 6.8 1.6 10.3 3 6.4 1.1 9.1 3 344 4 341 165 1.1 0 1.4 0.9 01/11/2006 18:00:00 8.7 1.3 11.5 4.9 8.3 1.8 11.8 3.4 7.5 1.5 11.1 4.2 344 5 342 165 0.9 0 1.1 0.9 01/11/2006 18:10:00 8.5 1 11.8 5.3 8.3 1.3 11.5 4.9 7.6 1.2 10.3 4.2 342 3 332 165 0.8 0 1.1 0.9 01/11/2006 18:20:00 9 1.2 11.5 5.7 9 1.3 11.8 5.7 8.4 1.2 11.5 5.3 339 6 339 165 0.7 0 1.1 0.7 01/11/2006 18:30:00 7.6 0.9 10.3 4.9 7.5 0.9 10.7 4.9 7.2 0.9 9.5 5.3 337 6 340 165 0.5 0 0.9 0.7 01/11/2006 18:40:00 8.9 1.1 11.5 6.1 8.8 1.3 11.8 5.3 8.4 1.3 11.5 5.7 342 6 339 165 0.8 0 0.9 0.7 01/11/2006 18:50:00 9.2 1 11.8 6.5 9.2 1.1 12.2 6.5 8.9 1 11.8 6.1 340 4 338 165 0.8 0 0.9 0.7 01/11/2006 19:00:00 8.9 1 11.8 6.1 8.9 1.1 12.6 4.9 8.5 1.1 11.5 5.7 338 4 340 165 0.8 0 0.9 0.7 01/11/2006 19:10:00 9.1 1 11.5 7.2 9.2 1 11.5 7.2 9 1 11.5 6.5 337 5 330 165 0.8 0 0.9 0.7 01/11/2006 19:20:00 7.9 1.2 11.8 5.7 7.9 1.3 12.2 5.7 7.7 1.3 11.5 5.3 329 10 342 165 0.7 0.1 0.9 0.4 01/11/2006 19:30:00 7.1 0.8 9.5 5.3 7 0.8 9.1 5.3 6.9 0.7 9.1 5.3 327 6 333 165 0.3 0 0.7 0.2 01/11/2006 19:40:00 7.7 0.8 9.5 4.9 7.7 0.8 9.9 4.9 7.6 0.7 9.5 4.9 337 5 344 165 0.7 0.1 0.9 0.2 01/11/2006 19:50:00 7.8 1.1 11.1 5.3 7.9 1.2 11.5 5.3 7.4 1.2 9.9 4.6 338 3 343 165 0.7 0 0.9 0.7 01/11/2006 20:00:00 8.6 1 11.1 6.5 8.6 1.1 11.8 4.9 8.3 0.9 10.3 5.7 338 7 345 165 0.7 0 0.9 0.7 01/11/2006 20:10:00 6.5 1.1 9.5 3.4 6.5 1.1 9.5 3.8 6.3 1 9.9 3.8 327 10 303 165 0.7 0 0.9 0.7 01/11/2006 20:20:00 5.9 0.7 8.4 4.2 5.8 0.7 8.4 3.8 5.6 0.7 7.6 3.4 333 9 340 165 0.4 0.1 0.7 0.2 01/11/2006 20:30:00 8 1.2 11.1 4.9 7.4 1.3 10.7 4.2 7.8 1.1 10.3 4.9 345 7 349 165 0.2 0 0.7 0.2 01/11/2006 20:40:00 6.9 1 9.5 4.2 6.8 1 9.5 4.2 6.1 1 9.1 3.4 313 10 306 165 0.1 0.1 0.7 -0.1 01/11/2006 20:50:00 7 1.2 10.3 4.2 6.9 1.2 11.1 4.2 6 1.2 8.8 2.6 307 4 304 165 0 0 0.2 -0.1 01/11/2006 21:00:00 9 1.1 12.2 6.1 8.9 1.1 11.8 5.7 7.2 1 9.9 4.2 304 5 299 165 -0.1 0 0.2 -0.1 01/11/2006 21:10:00 9.6 1.3 13 6.5 9.5 1.3 13 6.1 7.3 1.2 11.1 4.2 302 3 302 165 -0.1 0 -0.1 -0.1 01/11/2006 21:20:00 7.2 1.5 10.7 3.4 7.1 1.4 10.3 3.4 5.6 1.4 9.1 2.6 301 3 298 165 -0.3 0 -0.1 -0.3 01/11/2006 21:30:00 7.3 1.1 10.7 4.2 7.4 1.1 10.3 4.6 5.6 1.2 8.8 2.6 304 5 305 165 -0.3 0 -0.1 -0.5 01/11/2006 21:40:00 7 1.2 9.5 2.6 7.1 1.2 9.9 3 5.6 1.3 8.8 2.6 305 7 298 165 -0.3 0 -0.3 -0.5 01/11/2006 21:50:00 7.5 1 10.7 4.6 7.5 1 10.3 4.6 6.5 1 9.9 3.8 313 4 309 165 -0.3 0 -0.3 -0.5 01/11/2006 22:00:00 7.8 1.1 11.5 5.3 7.8 1.1 11.5 5.7 7 0.9 10.3 4.6 318 10 340 165 -0.3 0 -0.1 -0.5 01/11/2006 22:10:00 7.6 0.9 10.7 5.3 7.6 0.8 10.3 5.3 6.9 1 9.1 4.6 317 12 346 165 -0.2 0 -0.1 -0.3 01/11/2006 22:20:00 8.5 0.9 10.7 6.1 8.4 0.9 10.7 5.7 6.9 1 9.1 4.6 308 5 304 165 -0.2 0 -0.1 -0.3 01/11/2006 22:30:00 9.8 1.2 12.6 7.6 9.7 1.1 12.6 7.6 7.4 1.1 11.8 5.3 302 3 297 165 -0.1 0 0.2 -0.1 01/11/2006 22:40:00 10.8 1 12.6 8 10.6 1 12.6 7.6 8 1 11.1 5.3 301 1 300 165 -0.1 0 0.2 -0.1 01/11/2006 22:50:00 10.6 1.3 13.3 6.8 10.5 1.2 13.3 6.8 8.2 1.1 13.3 5.7 300 3 301 165 0 0 0.2 -0.1 01/11/2006 23:00:00 10.2 1 12.6 6.8 10.1 0.9 12.2 7.6 8 1.2 10.7 4.2 301 3 301 165 0 0 0.2 -0.1 01/11/2006 23:10:00 7.9 1.1 10.3 4.9 7.9 1 10.3 5.3 6.3 1 8.8 3.8 303 1 302 165 -0.1 0 0.2 -0.3 01/11/2006 23:20:00 8.4 1 10.3 5.3 8.3 1 10.3 5.3 6.7 0.9 9.5 3.4 305 1 304 165 -0.1 0 -0.1 -0.3 01/11/2006 23:30:00 9.3 1 12.2 6.8 9.2 0.9 11.8 6.8 7.2 1 10.7 4.9 304 3 297 165 -0.1 0 0.2 -0.1 01/11/2006 23:40:00 10.1 1.3 13.3 6.1 10 1.3 13 5.3 7.8 1.1 12.2 4.6 305 3 302 165 0 0 0.2 -0.1 01/11/2006 23:50:00 9.9 1.6 13.3 5.7 9.8 1.5 13.3 4.9 7.8 1.5 11.5 4.2 302 5 302 165 0.1 0 0.2 -0.1 01/12/2006 00:00:00 8.9 1.1 13 6.1 8.8 1.1 12.6 6.1 7.3 1.1 10.7 4.2 304 4 304 165 -0.1 0 0.2 -0.1 01/12/2006 00:10:00 7.6 0.9 9.5 4.9 7.6 0.9 9.5 4.9 6.2 0.9 8.8 3.4 308 5 305 165 -0.2 0 -0.1 -0.3 01/12/2006 00:20:00 7.5 1.1 10.3 4.2 7.4 1.1 10.3 4.2 6 1.1 9.9 3.4 306 2 307 165 -0.3 0 -0.1 -0.3 01/12/2006 00:30:00 8 1 10.3 5.7 8 1 10.7 5.3 6.9 1.3 10.7 3.8 311 6 307 165 -0.1 0.1 0.2 -0.3 01/12/2006 00:40:00 6.1 1.1 9.1 3.8 6.1 1 9.1 3.8 5.1 1 8 3 314 3 313 165 -0.1 0.2 0.2 -0.3 01/12/2006 00:50:00 8 2 13.7 3.4 7.7 1.9 13 3.8 7.6 1.8 12.2 3.8 336 13 358 165 -0.1 0.1 0.2 -0.3 01/12/2006 01:00:00 7.9 1.5 11.8 4.9 7.9 1.4 11.5 4.9 7.4 1.1 11.1 4.9 317 9 309 165 0.1 0 0.2 -0.1 01/12/2006 01:10:00 9.9 1.2 13 6.5 9.8 1.1 13 6.5 8.6 1.1 11.5 5.3 312 6 310 165 -0.1 0 0.2 -0.1 01/12/2006 01:20:00 8.8 1.3 11.5 4.9 8.7 1.3 11.5 5.3 8.1 1.2 11.1 4.6 318 6 312 165 -0.2 0 -0.1 -0.3 01/12/2006 01:30:00 8.6 1.1 11.5 5.7 8.5 1.1 11.5 5.7 7.4 1 9.9 4.6 313 6 316 165 -0.2 0 0.2 -0.3 01/12/2006 01:40:00 7 1 9.5 4.9 6.9 1 9.5 4.9 6.4 1 10.3 3.4 319 10 318 165 -0.2 0 -0.1 -0.3 01/12/2006 01:50:00 5.6 1.2 9.1 3 5.5 1.1 8.4 3 5.2 1 8 3 327 15 348 165 -0.2 0 -0.1 -0.3 01/12/2006 02:00:00 6.5 1.2 9.5 3.8 6.5 1.3 9.5 3.4 5.6 0.9 8.8 3.4 315 9 313 165 -0.3 0 -0.1 -0.3 01/12/2006 02:10:00 8.4 1.2 10.7 5.3 8.3 1.1 10.7 5.7 6.6 1.4 11.1 1.9 306 4 308 165 -0.4 0 -0.3 -0.5 01/12/2006 02:20:00 8.1 1.2 10.7 4.6 8.1 1.1 10.3 4.6 6.4 1.2 9.5 2.6 304 3 302 165 -0.5 0 -0.3 -0.5 01/12/2006 02:30:00 7.2 1 9.5 4.2 7.2 1.1 9.5 4.2 6.1 1.2 9.9 3.4 315 13 307 165 -0.4 0 -0.3 -0.5 01/12/2006 02:40:00 8.8 1.5 13 5.3 8.5 1.5 13.3 4.9 8.2 1.4 12.2 4.9 334 12 344 165 -0.1 0.1 0.2 -0.3 01/12/2006 02:50:00 8.9 1.1 12.2 5.3 8.8 1 11.8 5.3 8.3 1 11.1 5.3 329 12 343 165 0.1 0 0.2 -0.1 01/12/2006 03:00:00 9 1.3 12.2 5.3 8.6 1.4 13 4.9 8.3 1.3 11.8 4.6 330 16 346 165 -0.1 0 0.2 -0.3 01/12/2006 03:10:00 8.8 1.2 11.8 3.8 8.7 1.3 12.6 4.9 8.1 1.3 11.5 4.6 329 14 342 165 0.1 0 0.2 -0.1 01/12/2006 03:20:00 9.6 2.3 14.5 4.9 9 2.2 14.9 4.6 8.8 2.4 14.9 3.8 341 13 350 165 0.2 0 0.4 0.2 01/12/2006 03:30:00 11 1.3 14.1 6.1 10.7 1.7 14.9 5.7 10.3 1.5 13.7 4.6 344 8 343 165 0.3 0 0.7 0.2 01/12/2006 03:40:00 10 1.3 13.7 6.5 9.9 1.4 13.7 6.1 9.5 1.2 13 6.5 335 11 328 165 0.2 0 0.4 0.2 01/12/2006 03:50:00 9.7 1 11.8 6.5 9.6 1 12.2 6.5 9.1 1 11.1 6.1 319 9 300 165 0.1 0 0.2 -0.1 01/12/2006 04:00:00 8.7 1.2 11.5 6.1 8.7 1.2 11.5 6.1 7.8 1.1 11.8 5.3 315 8 311 165 0.2 0 0.2 -0.1 01/12/2006 04:10:00 7.7 0.8 9.9 5.7 7.7 0.8 9.9 5.3 7.1 0.9 9.5 4.9 314 9 308 165 0.1 0 0.2 -0.1 01/12/2006 04:20:00 6.7 1.1 9.5 3.8 6.6 1 9.5 3.8 6.3 0.9 8.4 3.8 320 13 305 165 0 0 0.2 -0.1 01/12/2006 04:30:00 7 0.6 8.4 4.9 6.9 0.6 8.4 5.7 6.3 0.8 8.4 4.2 312 7 310 165 -0.2 0 -0.1 -0.3 01/12/2006 04:40:00 6.3 1.2 8.8 3.4 6.3 1.2 8.8 3.4 6.4 1 8.8 4.2 334 10 350 165 -0.2 0 -0.1 -0.3 01/12/2006 04:50:00 5.9 0.8 7.6 4.2 5.9 0.7 7.2 3.8 5.7 0.8 7.6 3.4 319 11 323 165 -0.3 0 -0.1 -0.3 01/12/2006 05:00:00 5.7 1 8 3.4 5.7 1 8.8 3.4 5.2 0.7 7.6 3.4 316 13 310 165 -0.3 0 -0.1 -0.3 01/12/2006 05:10:00 6.6 1 9.9 3.8 6.5 1 9.9 3.8 5.5 0.8 7.6 3 305 6 292 165 -0.3 0 -0.1 -0.3 01/12/2006 05:20:00 6.1 0.8 9.1 3.8 6.1 0.8 8.8 4.2 5.5 1 9.1 3 314 10 326 165 -0.2 0 -0.1 -0.3 01/12/2006 05:30:00 6 0.8 8 3.8 6 0.8 8 3.8 5.2 0.7 7.2 2.6 309 6 304 165 -0.3 0 -0.1 -0.5 01/12/2006 05:40:00 6.2 0.9 9.5 4.2 6.1 0.9 9.5 4.2 5.7 0.9 9.5 3.8 318 10 322 165 -0.3 0 -0.3 -0.5 01/12/2006 05:50:00 7.1 1 10.3 4.9 7.1 1 10.7 4.9 5.5 1.1 9.5 3 302 6 301 165 -0.3 0 -0.1 -0.5 01/12/2006 06:00:00 8.4 1 10.7 6.1 8.3 1 11.1 6.1 6.9 1 10.3 4.2 306 6 301 165 -0.4 0 -0.3 -0.5 01/12/2006 06:10:00 8.3 1.2 12.2 6.1 8.2 1.2 11.5 6.1 6.8 1 9.9 4.6 305 6 301 165 -0.3 0 -0.1 -0.5 01/12/2006 06:20:00 8.1 1 11.8 6.1 8 1 12.2 5.3 7.7 1.4 11.5 4.6 321 14 330 165 -0.4 0 -0.3 -0.5 01/12/2006 06:30:00 8.7 1.2 11.8 5.7 8.5 1.4 11.8 5.7 8.4 1.3 12.2 4.9 338 10 331 165 -0.3 0 -0.1 -0.5 01/12/2006 06:40:00 10 1.7 14.1 5.3 9.5 1.7 13.7 4.9 10 1.8 14.1 5.7 341 11 355 165 -0.3 0 -0.3 -0.5 01/12/2006 06:50:00 10.1 2 14.1 5.7 9.7 2.1 14.1 4.9 10 2.3 14.5 4.9 342 10 342 165 -0.3 0 -0.1 -0.5 01/12/2006 07:00:00 7.9 1.1 11.1 4.2 7.8 1.2 11.5 4.9 7.6 1.1 11.1 4.9 336 13 344 165 -0.4 0 -0.3 -0.5 01/12/2006 07:10:00 7.4 1 11.1 5.3 7.2 1.2 11.8 3.8 7.2 1.1 10.7 4.6 336 11 344 165 -0.5 0 -0.5 -0.8 01/12/2006 07:20:00 6.7 1.1 9.5 4.6 6.6 1.1 9.5 4.6 6.2 1 9.5 4.2 329 15 340 165 -0.8 0.1 -0.5 -1 01/12/2006 07:30:00 6.1 1 8.4 3.8 6 1 8.8 4.2 5.8 0.9 8 3.8 327 12 315 165 -0.9 0 -0.8 -1 01/12/2006 07:40:00 8.1 1.2 11.5 5.3 7.7 1.3 11.1 4.2 7.8 1.2 10.7 4.9 343 9 343 165 -0.9 0 -0.8 -1 01/12/2006 07:50:00 8.2 1.2 11.8 5.7 7.9 1 11.5 5.7 8 1.2 11.8 4.9 332 14 355 165 -0.9 0 -0.8 -1 01/12/2006 08:00:00 8.7 1.4 11.8 4.2 8 1.4 11.5 4.2 8.4 1.4 11.8 4.6 345 13 358 165 -0.7 0 -0.5 -0.8 01/12/2006 08:10:00 7.7 1.4 11.8 4.9 7.6 1.5 11.8 4.9 7.5 1.2 11.1 5.3 336 12 339 165 -0.5 0 -0.3 -0.8 01/12/2006 08:20:00 7.8 1 10.3 5.7 7.7 1 10.3 5.3 6.8 1 9.5 4.6 312 7 300 165 -0.8 0.1 -0.5 -0.8 01/12/2006 08:30:00 8.5 1.2 11.8 6.1 8.5 1.2 11.8 5.3 7.1 1.1 10.7 4.2 307 8 310 165 -0.8 0.1 -0.5 -1 01/12/2006 08:40:00 9.8 1 11.8 7.2 9.7 0.9 11.8 7.2 7.8 1 10.7 5.7 306 6 301 165 -0.9 0 -0.8 -1 01/12/2006 08:50:00 10.1 1 13.7 7.6 10 1 13.3 7.2 8 1 11.1 5.7 307 5 309 165 -1 0 -0.8 -1.2 01/12/2006 09:00:00 10.4 1.1 13.3 7.2 10.3 1.1 13 7.2 8.7 1.3 11.8 5.3 309 6 304 165 -1.2 0 -1 -1.4 01/12/2006 09:10:00 11 1 14.9 8.4 10.9 1 14.5 8.4 9.2 1 12.2 6.8 308 6 302 165 -1.2 0 -0.8 -1.4 01/12/2006 09:20:00 11.3 1.2 14.9 8.8 11.2 1.1 14.5 8.8 8.9 1.5 14.9 6.1 305 8 312 165 -0.9 0 -0.8 -1.2 01/12/2006 09:30:00 11.7 1 16.1 8.4 11.6 1 16.1 8.4 8.5 1.3 14.1 6.1 302 5 296 165 -0.9 0 -0.8 -1.2 01/12/2006 09:40:00 11.7 1.3 16.4 8.8 11.6 1.3 16.1 8.8 8.7 1.5 13.3 5.7 301 6 309 165 -0.9 0 -0.8 -1.2 01/12/2006 09:50:00 11.8 1.7 17.2 8.4 11.7 1.7 16.8 8.8 9.8 2.1 17.2 5.3 304 9 310 165 -0.8 0.1 -0.5 -1.2 01/12/2006 10:00:00 11.7 1.5 16.1 8 11.6 1.5 16.4 7.6 9.8 1.8 15.3 6.1 307 9 304 165 -0.5 0.1 -0.3 -0.8 01/12/2006 10:10:00 12.1 1 14.9 10.3 12.1 1 14.5 10.3 9.6 1.1 12.6 7.2 308 5 305 165 -0.9 0 -0.8 -1 01/12/2006 10:20:00 13 1.1 16.1 10.3 12.8 1.1 15.6 9.5 10.5 1.3 14.1 7.2 307 5 306 165 -1 0 -0.8 -1.2 01/12/2006 10:30:00 11.9 1.1 14.1 8.4 11.8 1.1 14.1 8.4 9.9 1.3 13 6.1 308 5 310 165 -1 0 -0.8 -1.2 01/12/2006 10:40:00 12.3 1.1 15.3 8.8 12.2 1.1 15.3 8.4 11 1.1 15.3 8 312 5 306 165 -1 0 -0.8 -1.2 01/12/2006 10:50:00 12.9 0.9 14.9 11.1 12.8 0.9 14.9 10.7 11.7 1.1 14.1 8 312 4 310 165 -1 0 -0.8 -1.2 01/12/2006 11:00:00 13.1 1.1 17.9 10.7 13 1.1 17.6 10.3 11.8 1.3 14.9 8 311 6 304 165 -0.9 0 -0.8 -1.2 01/12/2006 11:10:00 12.9 1.3 16.4 9.9 12.8 1.2 16.1 9.9 11.2 1.6 15.3 7.2 310 7 312 165 -0.8 0 -0.5 -0.8 01/12/2006 11:20:00 11.7 1.2 14.9 7.2 11.6 1.2 14.5 8 9.6 1.1 13.3 6.5 307 6 323 165 -0.6 0 -0.3 -0.8 01/12/2006 11:30:00 10.3 1.5 14.1 6.8 10.2 1.5 14.1 6.5 8.7 1.5 13.3 4.9 308 7 310 165 -0.6 0 -0.3 -0.8 01/12/2006 11:40:00 8.4 1 11.1 6.1 8.3 1 11.1 6.1 6.9 1 9.9 4.2 309 7 301 165 -0.3 0.1 0.2 -0.5 01/12/2006 11:50:00 6.5 1.7 9.5 1.1 6.5 1.6 9.5 1.1 4.8 1.9 8.8 0.4 306 17 290 165 0.3 0.2 0.9 -0.1 01/12/2006 12:00:00 8 1.3 11.5 4.2 7.9 1.3 11.1 4.2 6.1 1.5 10.3 2.3 299 11 301 165 0.4 0.1 0.9 0.2 01/12/2006 12:10:00 7.6 1.3 10.3 3.8 7.6 1.2 10.3 3.8 6 1.5 9.5 3 301 10 293 165 0.2 0.1 0.7 0.2 01/12/2006 12:20:00 6.5 1.2 10.3 3.8 6.4 1.1 9.5 3.8 5.2 1 8.8 3 306 10 299 165 0.1 0 0.7 -0.1 01/12/2006 12:30:00 6.8 0.9 9.5 3.8 6.7 0.8 9.5 4.2 5.7 1 9.1 3.4 306 11 291 165 0.1 0 0.2 -0.1 01/12/2006 12:40:00 6.9 1.1 9.1 4.6 6.9 1.1 9.1 4.6 5.9 0.9 8.8 3 309 13 313 165 -0.3 0.1 0.2 -0.5 01/12/2006 12:50:00 7.1 1.6 11.5 3 7 1.6 11.5 3 6.7 1.6 10.7 2.6 332 16 339 165 -0.1 0.1 0.2 -0.3 01/12/2006 13:00:00 7.2 2.3 11.8 3.4 7.2 2.2 11.8 3.4 5.7 1.6 9.9 3 301 10 286 165 -0.5 0.2 0.2 -1 01/12/2006 13:10:00 7.8 1.3 11.1 4.6 7.8 1.2 11.1 4.9 6.5 1.2 10.3 3.8 300 9 302 165 -0.8 0 -0.5 -1 01/12/2006 13:20:00 6.8 1.5 10.7 3.8 6.9 1.5 10.3 3.4 5.6 1 8.4 3 307 12 296 165 -0.5 0.2 -0.1 -0.8 01/12/2006 13:30:00 6.7 1.6 10.3 2.3 6.7 1.5 10.3 2.6 5.6 1.3 9.5 2.3 295 9 294 165 -0.8 0.1 -0.3 -1 01/12/2006 13:40:00 7.9 1.3 11.1 4.9 7.9 1.2 11.1 4.9 6.4 1.3 10.3 3.4 297 7 291 165 -1 0.1 -0.8 -1.4 01/12/2006 13:50:00 9.8 1.3 13.3 6.8 9.8 1.3 13.3 6.8 8 1.2 11.5 4.9 296 6 295 165 -1.4 0 -1.2 -1.4 01/12/2006 14:00:00 9.8 1.2 12.2 6.8 9.8 1.2 12.6 6.8 7.9 1.3 11.1 4.9 295 5 310 165 -1.6 0 -1.4 -1.7 01/12/2006 14:10:00 11 1.1 13.7 6.5 11 1.2 13.7 6.8 8.9 1.4 13 4.9 295 5 295 165 -1.6 0 -1.4 -1.7 01/12/2006 14:20:00 12.1 0.7 13.7 9.9 12.2 0.7 13.7 10.3 9.8 1.3 13.3 6.8 294 4 288 165 -1.7 0 -1.7 -1.9 01/12/2006 14:30:00 12.4 0.9 14.5 9.9 12.4 0.9 14.5 9.5 9 1 12.2 6.5 297 4 300 165 -1.9 0 -1.7 -1.9 01/12/2006 14:40:00 11.9 1 14.1 8.4 11.8 1 14.1 8 9.2 1.2 12.6 6.1 295 5 295 165 -2 0 -1.7 -2.1 01/12/2006 14:50:00 11.3 1.1 14.5 8.4 11.2 1.1 14.1 8 8.5 1.1 11.8 5.7 297 6 301 165 -2.1 0 -1.9 -2.1 01/12/2006 15:00:00 10.6 0.9 12.6 7.6 10.5 0.9 12.6 7.6 8.1 1.1 11.8 5.7 296 6 298 165 -2.1 0 -1.9 -2.1 01/12/2006 15:10:00 10.8 0.9 13 8.4 10.7 0.9 13 8.4 8.1 1.1 13 5.7 299 6 302 165 -2.2 0 -2.1 -2.4 01/12/2006 15:20:00 10.9 0.8 13 9.1 10.9 0.8 13 8.8 8.4 1 11.8 6.1 303 6 302 165 -2.3 0 -2.1 -2.6 01/12/2006 15:30:00 12.1 1.5 15.3 7.2 12 1.5 15.3 7.2 9.8 1.5 14.1 5.7 306 7 310 165 -2.4 0 -2.1 -2.6 01/12/2006 15:40:00 11.5 1.2 14.5 8.4 11.4 1.3 14.1 8.4 9.9 1.3 14.1 6.8 307 6 304 165 -2.5 0 -2.4 -2.6 01/12/2006 15:50:00 12 1.3 15.3 8 11.9 1.3 15.3 8.8 9.3 1.2 13.3 6.5 305 6 297 165 -2.6 0 -2.6 -2.8 01/12/2006 16:00:00 12 1.2 15.6 8.4 12 1.2 15.6 8.8 9.7 1.3 14.1 6.1 307 6 303 165 -2.8 0 -2.6 -2.8 01/12/2006 16:10:00 11.7 1.3 14.9 7.6 11.7 1.3 14.5 7.6 9.1 1.2 13 6.5 304 6 300 165 -2.9 0.1 -2.6 -3 01/12/2006 16:20:00 11.7 1.1 14.9 7.6 11.6 1.1 14.5 6.8 9 1.2 12.2 6.1 298 6 301 165 -3 0 -2.8 -3.3 01/12/2006 16:30:00 11.9 1 14.1 9.5 11.9 1 14.1 9.1 8.8 1 11.8 6.5 299 6 303 165 -3.3 0 -3 -3.5 01/12/2006 16:40:00 12.9 1 14.9 10.3 12.8 1 14.9 10.3 9 1.1 13.3 6.5 299 4 300 165 -3.4 0 -3.3 -3.5 01/12/2006 16:50:00 12.3 1 14.1 8.4 12.2 1 14.1 8.8 8.8 1 12.2 6.8 301 5 300 165 -3.5 0 -3.3 -3.5 01/12/2006 17:00:00 12.6 1.1 15.3 9.5 12.5 1 15.3 9.1 8.9 1 12.2 6.8 302 4 300 165 -3.5 0 -3.3 -3.5 01/12/2006 17:10:00 12.5 1.1 14.9 9.5 12.5 1.1 14.9 9.5 8.6 0.9 12.2 6.5 300 4 294 165 -3.6 0 -3.5 -3.5 01/12/2006 17:20:00 12.4 1 14.9 9.5 12.3 1 14.9 9.5 8.6 0.9 11.5 6.1 301 4 304 165 -3.7 0 -3.5 -3.7 01/12/2006 17:30:00 12.1 1.1 14.9 9.1 12.1 1.1 14.9 9.1 8.8 1 12.2 6.8 301 5 297 165 -3.6 0 -3.5 -3.5 01/12/2006 17:40:00 12 1.3 15.3 8.4 12 1.2 14.9 8.4 8.7 1.2 12.2 6.1 300 5 297 165 -3.5 0 -3.3 -3.5 01/12/2006 17:50:00 12.6 0.9 14.5 9.9 12.6 0.9 14.5 9.9 8.9 1.1 12.6 6.1 299 4 297 165 -3.5 0 -3.3 -3.5 01/12/2006 18:00:00 13.1 1.1 14.9 9.1 13 1.1 14.9 9.5 9.1 1.1 12.6 6.5 298 4 296 165 -3.4 0 -3.3 -3.5 01/12/2006 18:10:00 12.9 1.1 15.3 9.5 12.9 1.1 15.3 9.5 8.9 1 12.6 6.1 299 4 295 165 -3.5 0 -3.3 -3.5 01/12/2006 18:20:00 12.3 1.2 14.9 8.4 12.2 1.2 14.5 8.4 8.7 1 11.5 6.1 300 5 294 165 -3.4 0 -3.3 -3.5 01/12/2006 18:30:00 11.3 1.3 14.1 7.2 11.2 1.3 14.1 6.8 8.6 1.5 13 4.9 297 5 298 165 -3.3 0 -3.3 -3.5 01/12/2006 18:40:00 11.8 1.2 14.5 8.4 11.8 1.1 14.5 8.4 8.8 1.2 12.2 6.1 296 5 293 165 -3.3 0 -3.3 -3.5 01/12/2006 18:50:00 12.7 1.1 15.3 9.9 12.7 1.1 15.3 10.3 9 1.1 12.2 6.5 300 4 297 165 -3.3 0 -3 -3.5 01/12/2006 19:00:00 12.4 1.2 15.6 8.8 12.4 1.2 16.1 8.8 9.1 1.5 13.7 6.1 296 5 300 165 -3.2 0 -3 -3.3 01/12/2006 19:10:00 12.3 1 14.9 9.1 12.2 1 14.5 8.8 9.1 1.2 13 6.5 303 5 300 165 -3.2 0 -3 -3.3 01/12/2006 19:20:00 11.7 1.3 13.7 6.5 11.7 1.3 13.7 6.8 8.9 1.1 13 6.5 304 5 302 165 -3.2 0 -3 -3.3 01/12/2006 19:30:00 11.3 1.3 14.1 7.2 11.2 1.3 13.7 6.8 8.9 1.3 12.2 5.3 305 6 302 165 -3.3 0 -3.3 -3.3 01/12/2006 19:40:00 10.1 1.3 13 6.5 10.1 1.3 13 6.5 8 1 10.7 5.3 304 6 308 165 -3.4 0 -3.3 -3.5 01/12/2006 19:50:00 10.8 1.1 13.7 6.5 10.8 1.1 13.3 6.1 8 1 11.1 5.3 299 6 307 165 -3.4 0 -3.3 -3.5 01/12/2006 20:00:00 10.4 1.1 13 6.8 10.4 1.1 12.6 7.2 8 1.1 11.8 5.3 300 6 295 165 -3.4 0 -3.3 -3.5 01/12/2006 20:10:00 10.2 1.3 13 6.5 10.2 1.3 13 6.5 8.1 1.2 12.6 5.7 300 7 307 165 -3.3 0 -3.3 -3.5 01/12/2006 20:20:00 10.8 1.7 14.1 6.1 10.8 1.7 14.1 6.1 8.2 1.3 11.8 4.9 299 6 302 165 -3.4 0 -3.3 -3.5 01/12/2006 20:30:00 12.1 1 14.1 8.4 12.1 1 14.1 8.8 8.9 1.1 12.2 6.1 298 5 290 165 -3.5 0 -3.3 -3.5 01/12/2006 20:40:00 12.4 1 14.9 9.5 12.4 1 14.9 9.1 9.1 1.2 12.2 6.8 301 6 311 165 -3.5 0 -3.3 -3.5 01/12/2006 20:50:00 12.2 1.2 14.9 8 12.2 1.2 14.9 8 8.7 1.1 12.6 5.3 301 5 301 165 -3.5 0 -3.3 -3.5 01/12/2006 21:00:00 11.8 1.2 14.1 8.8 11.7 1.1 14.1 8.8 8.7 1.2 12.6 6.1 300 6 288 165 -3.6 0 -3.3 -3.5 01/12/2006 21:10:00 12.1 1.2 14.5 8.8 12.1 1.2 14.5 8.8 8.8 1.1 13 5.7 298 5 296 165 -3.6 0 -3.5 -3.5 01/12/2006 21:20:00 11.8 0.9 13.7 8.8 11.8 0.9 14.1 8.8 8.7 1 12.2 6.1 301 5 297 165 -3.6 0 -3.5 -3.5 01/12/2006 21:30:00 11.4 1.5 14.1 7.6 11.4 1.5 14.1 7.6 8.3 1.1 11.8 4.9 299 5 298 165 -3.6 0 -3.5 -3.5 01/12/2006 21:40:00 11.1 1.3 14.1 7.2 11.1 1.3 14.1 7.2 8.6 1.5 12.6 4.9 297 6 296 165 -3.6 0 -3.5 -3.7 01/12/2006 21:50:00 10.8 1 13.3 7.2 10.8 1 13 7.6 8.3 1.1 11.5 5.7 299 6 293 165 -3.6 0 -3.5 -3.7 01/12/2006 22:00:00 10.8 1.1 13.7 8.4 10.8 1.1 13.7 8.4 8.6 1.2 12.6 5.7 295 6 294 165 -3.6 0 -3.5 -3.7 01/12/2006 22:10:00 11.2 1.1 13.7 7.6 11.1 1.1 13.3 7.6 8.8 1.2 12.2 5.7 296 6 293 165 -3.6 0 -3.5 -3.5 01/12/2006 22:20:00 11.3 1.1 13.7 8.4 11.3 1.1 13.7 8.4 8.6 1.2 12.6 5.7 296 5 294 165 -3.6 0 -3.5 -3.7 01/12/2006 22:30:00 10.1 1.2 12.6 6.8 10.1 1.2 13 6.5 8.2 1.5 11.8 4.9 296 7 302 165 -3.6 0 -3.5 -3.5 01/12/2006 22:40:00 10.1 1.1 13 7.2 10.1 1.1 12.6 7.2 8.6 1.3 13 6.1 294 6 291 165 -3.6 0 -3.5 -3.9 01/12/2006 22:50:00 9.4 1 11.8 6.8 9.5 1 12.2 6.8 8.1 1.3 12.2 5.3 294 8 288 165 -3.7 0 -3.5 -3.7 01/12/2006 23:00:00 9.5 1.3 12.6 6.8 9.5 1.3 12.6 6.5 8.4 1.4 11.8 4.9 292 8 294 165 -3.7 0 -3.5 -3.9 01/12/2006 23:10:00 10.3 1.1 13.3 7.2 10.4 1.1 13 6.8 9.3 1.5 12.6 5.7 290 7 297 165 -3.7 0 -3.5 -3.9 01/12/2006 23:20:00 10.5 1.3 13 6.5 10.5 1.3 13 6.8 8.5 1.3 12.6 4.9 295 6 288 165 -3.7 0 -3.5 -3.9 01/12/2006 23:30:00 9.6 0.9 12.2 7.2 9.5 0.9 11.8 7.2 8 1.2 10.7 4.9 292 7 295 165 -3.7 0 -3.5 -3.9 01/12/2006 23:40:00 10.4 1.5 13 6.5 10.4 1.5 13 6.5 8.7 1.7 12.6 4.2 294 7 289 165 -3.8 0 -3.5 -3.9 01/12/2006 23:50:00 10.6 1.3 13.3 7.6 10.6 1.4 13.3 7.6 8.4 1.5 12.2 5.3 295 6 295 165 -3.8 0 -3.7 -3.9 01/13/2006 00:00:00 9.9 1 12.6 6.8 9.9 1 12.6 7.2 8.2 1.3 12.2 5.3 294 6 283 165 -3.8 0 -3.5 -3.9 01/13/2006 00:10:00 9.7 1.2 13 6.5 9.7 1.2 12.6 6.8 8.5 1.3 12.2 5.7 292 8 291 165 -3.8 0 -3.5 -3.9 01/13/2006 00:20:00 10.2 1.1 13.3 7.6 10.2 1.1 13.3 7.2 8 1.2 11.5 5.3 296 7 301 165 -3.9 0 -3.7 -4.2 01/13/2006 00:30:00 9.4 1.3 13.3 6.1 9.4 1.3 12.6 5.7 8.3 1.5 12.6 4.9 293 8 295 165 -3.8 0 -3.7 -3.9 01/13/2006 00:40:00 11.1 1 13.3 8 11.1 1 13 8 8.6 1.3 13 5.7 297 5 293 165 -3.9 0 -3.7 -3.9 01/13/2006 00:50:00 11.2 1 13.7 8.4 11.2 1 13.3 8.4 8.2 1 11.1 5.7 298 4 295 165 -3.9 0 -3.9 -4.2 01/13/2006 01:00:00 11.5 0.8 13.7 8.8 11.5 0.9 13.7 8.4 8.6 1.1 12.6 5.7 297 5 303 165 -4 0 -3.9 -4.2 01/13/2006 01:10:00 10.4 0.9 12.6 7.6 10.4 0.9 12.6 7.2 7.9 1.1 11.1 5.7 299 6 300 165 -4.1 0 -3.9 -4.2 01/13/2006 01:20:00 11.4 0.8 13.7 8.8 11.3 0.8 13.3 8.4 8.5 1.1 12.6 5.7 304 5 302 165 -4.1 0 -3.9 -4.2 01/13/2006 01:30:00 11.3 1.1 13.7 8 11.2 1.1 13.3 8.4 8.5 1.2 12.6 5.7 304 6 302 165 -3.9 0 -3.9 -4.2 01/13/2006 01:40:00 10.7 0.8 12.6 8.4 10.7 0.8 12.6 8.4 8 1 10.7 6.1 303 5 297 165 -3.9 0 -3.7 -4.2 01/13/2006 01:50:00 10.5 1.2 13 6.8 10.5 1.2 13.3 6.8 8.1 1.1 12.2 5.7 304 6 304 165 -4 0 -3.9 -4.2 01/13/2006 02:00:00 11.2 1.2 13 7.2 11.2 1.1 13 7.6 8.2 1 10.7 5.7 300 5 298 165 -4 0 -3.9 -4.2 01/13/2006 02:10:00 9.3 1.2 12.2 6.1 9.3 1.2 12.2 6.1 7.7 0.9 10.7 5.3 308 9 304 165 -4.1 0 -3.9 -4.2 01/13/2006 02:20:00 8.4 1.6 12.6 5.3 8.5 1.5 12.6 4.9 7.3 1.3 12.2 4.2 299 11 293 165 -3.8 0.2 -3.5 -4.2 01/13/2006 02:30:00 10.3 1.1 12.6 7.2 10.3 1.1 13 7.6 7.8 1 12.2 5.3 302 6 301 165 -3.9 0 -3.5 -4.2 01/13/2006 02:40:00 10.5 1.2 13 7.2 10.4 1.2 13 7.2 8.3 1.1 11.5 5.7 305 6 302 165 -4 0.1 -3.9 -4.2 01/13/2006 02:50:00 11.3 1 13.7 8.4 11.2 1 13.3 8.8 8.2 1 11.1 6.1 302 5 302 165 -4.1 0 -3.9 -4.2 01/13/2006 03:00:00 11.3 0.9 13.3 8.4 11.3 1 13.3 8.4 8.1 0.9 10.7 5.7 302 5 304 165 -4.2 0 -3.9 -4.2 01/13/2006 03:10:00 11.6 0.8 13.7 9.1 11.6 0.8 13.7 9.5 8 0.9 11.1 6.1 301 4 299 165 -4.2 0 -3.9 -4.4 01/13/2006 03:20:00 10.9 1 13 7.6 10.8 1 13.3 8 7.7 0.9 10.7 4.9 300 5 298 165 -4.2 0 -3.9 -4.4 01/13/2006 03:30:00 9 1.1 12.2 6.5 9 1.1 11.8 6.5 7.2 1.1 10.3 4.6 299 7 300 165 -4.2 0 -3.9 -4.4 01/13/2006 03:40:00 10.8 1.3 13 5.3 10.8 1.3 13 5.3 8 1 11.5 5.7 302 6 304 165 -4.1 0 -3.9 -4.4 01/13/2006 03:50:00 11.1 1.1 13.7 8 11.1 1.1 13.7 7.6 8.6 1.2 12.2 6.1 303 6 306 165 -4.2 0 -3.9 -4.2 01/13/2006 04:00:00 11 0.8 13 8.8 11 0.8 13 8.8 8.2 0.8 10.7 5.7 303 5 304 165 -4.1 0 -3.9 -4.2 01/13/2006 04:10:00 9.9 1 12.6 7.2 9.9 1 13 7.2 8.1 1 11.5 6.1 306 6 307 165 -4 0 -3.9 -4.2 01/13/2006 04:20:00 10.9 1.2 13.3 7.6 10.9 1.2 13.3 7.2 8 1.1 11.5 5.3 301 5 299 165 -4 0.1 -3.9 -4.2 01/13/2006 04:30:00 11.1 0.7 13.3 8.8 11.1 0.7 13 8.8 8 0.8 10.7 5.7 301 5 300 165 -4.1 0 -3.9 -4.4 01/13/2006 04:40:00 11.5 0.8 13.7 9.5 11.5 0.8 13.7 9.5 8.3 1.1 11.5 6.1 299 4 302 165 -4.2 0 -3.9 -4.4 01/13/2006 04:50:00 11 1 13.3 8 11 1 13 7.2 7.9 1 11.5 5.3 301 5 302 165 -4.2 0 -3.9 -4.4 01/13/2006 05:00:00 11 0.7 13.3 9.1 11 0.7 13 9.1 8 0.9 10.3 6.1 301 5 299 165 -4.2 0 -3.9 -4.4 01/13/2006 05:10:00 10.8 0.9 13 8 10.8 0.9 12.6 8.4 8 1 11.1 6.1 303 6 301 165 -4.2 0 -3.9 -4.4 01/13/2006 05:20:00 10.3 1 12.2 7.6 10.2 0.9 12.2 7.6 7.9 1.1 10.3 4.9 303 7 303 165 -4.1 0 -3.9 -4.2 01/13/2006 05:30:00 9 1.3 11.8 6.1 9 1.2 12.2 6.5 7.6 1.2 11.8 5.3 306 9 297 165 -3.9 0 -3.7 -4.2 01/13/2006 05:40:00 10.8 0.9 13 8.4 10.7 0.9 13 8 8.3 1.4 12.2 5.3 304 7 316 165 -4.2 0 -3.9 -4.4 01/13/2006 05:50:00 9.7 1.2 13.3 5.7 9.7 1.2 13.3 6.1 8.6 1.3 12.6 5.3 310 8 307 165 -4 0.1 -3.5 -4.4 01/13/2006 06:00:00 6.9 1.8 11.8 3 6.9 1.7 11.5 3 6.3 1.3 10.3 3.8 314 11 302 165 -3.8 0 -3.5 -3.9 01/13/2006 06:10:00 3.3 1 6.5 0.7 3.4 1 6.1 1.1 3.1 0.9 5.7 1.1 307 18 289 165 -3.9 0 -3.5 -4.2 01/13/2006 06:20:00 3.8 1 5.7 0.7 3.9 1 6.1 0.7 3.5 0.8 6.8 1.9 304 14 289 165 -4 0 -3.7 -4.2 01/13/2006 06:30:00 3.5 1 7.2 1.5 3.7 1.1 7.6 1.5 3.6 1.3 8.4 1.1 282 12 272 165 -4 0 -3.7 -4.2 01/13/2006 06:40:00 6.5 1.4 9.9 3.4 6.6 1.4 9.9 3.4 5.8 1.1 8.8 3.4 295 9 298 165 -4 0 -3.9 -4.2 01/13/2006 06:50:00 8.2 1.5 11.8 4.6 8.2 1.5 11.8 4.2 6.7 1.2 11.1 3.4 300 8 301 165 -4 0 -3.7 -4.2 01/13/2006 07:00:00 9 1.2 11.8 6.1 9 1.2 11.8 5.7 7.1 1 9.9 4.6 304 6 302 165 -3.9 0 -3.7 -4.2 01/13/2006 07:10:00 10.2 1.1 13 7.6 10.1 1.1 13 7.2 8.5 1.1 11.1 5.3 308 7 312 165 -4 0.1 -3.7 -4.4 01/13/2006 07:20:00 10.2 1.1 13 7.6 10.1 1.1 12.6 7.2 8 1 10.7 5.7 307 8 307 165 -4.2 0 -3.9 -4.4 01/13/2006 07:30:00 7.9 2 11.5 3.8 7.9 1.9 11.1 3.8 6.9 1.4 10.3 3.8 313 13 301 165 -4.2 0 -3.9 -4.4 01/13/2006 07:40:00 5.6 1 8.4 4.2 5.6 0.9 8.4 3.8 4.9 0.9 8 3 308 10 307 165 -4.2 0 -3.9 -4.4 01/13/2006 07:50:00 7.4 1 10.3 4.6 7.5 1 9.9 4.9 6 0.9 8.8 3.8 302 8 302 165 -4 0.1 -3.7 -4.4 01/13/2006 08:00:00 8.3 0.9 10.7 5.7 8.3 0.9 11.5 5.7 6.6 1 10.7 4.9 299 7 288 165 -4.1 0 -3.9 -4.4 01/13/2006 08:10:00 8.4 1.3 11.5 5.3 8.4 1.3 11.5 5.3 6.9 1.4 11.5 3.8 300 11 299 165 -4 0 -3.9 -4.2 01/13/2006 08:20:00 9.8 1.3 12.6 4.9 9.8 1.2 12.6 5.3 8.2 1.2 11.8 4.9 302 8 296 165 -4 0.1 -3.9 -4.2 01/13/2006 08:30:00 9.8 1 12.2 6.5 9.7 1 11.8 6.8 7.7 0.9 11.1 5.3 304 7 295 165 -4 0 -3.7 -4.2 01/13/2006 08:40:00 7.2 1.3 9.9 3.8 7.2 1.3 9.9 3.8 6.7 1.1 9.9 3.4 311 9 310 165 -4 0 -3.9 -4.4 01/13/2006 08:50:00 7.1 0.8 9.1 4.6 7.1 0.8 9.1 4.6 6.6 0.7 8.4 4.2 315 9 309 165 -4.3 0 -4.2 -4.6 01/13/2006 09:00:00 9.2 1.2 11.8 5.7 9.1 1.2 11.8 5.7 7.7 1.1 11.1 4.9 308 9 304 165 -4.4 0.2 -3.9 -4.6 01/13/2006 09:10:00 9.4 1.1 12.6 5.7 9.3 1.1 12.2 5.7 7.8 1 10.7 5.3 308 6 295 165 -4.3 0.1 -3.9 -4.6 01/13/2006 09:20:00 8.5 1.2 11.1 5.3 8.4 1.1 10.7 6.1 6.7 1.2 10.3 4.2 302 8 312 165 -4.7 0 -4.6 -4.8 01/13/2006 09:30:00 8.9 1 11.5 6.1 8.8 1 11.5 6.1 6.9 1 9.9 4.6 300 7 307 165 -4.7 0 -4.6 -4.6 01/13/2006 09:40:00 9.5 0.9 11.1 7.2 9.5 0.9 11.5 7.2 7.2 0.9 10.3 4.9 301 6 300 165 -4.6 0 -4.4 -4.6 01/13/2006 09:50:00 10.2 0.8 12.2 7.6 10.2 0.8 12.2 7.6 7.8 0.9 10.3 5.3 304 5 302 165 -4.4 0 -4.2 -4.6 01/13/2006 10:00:00 9.7 1 12.2 7.2 9.6 1.1 12.2 6.8 8 1.3 11.5 5.3 307 6 302 165 -4 0.1 -3.7 -4.4 01/13/2006 10:10:00 8.7 1.4 11.1 4.2 8.7 1.3 11.1 4.6 6.8 1 10.3 4.2 299 8 301 165 -4 0.2 -3.5 -4.2 01/13/2006 10:20:00 9.4 1 12.2 6.5 9.4 1 11.8 6.5 7.5 1.1 11.1 4.9 298 7 292 165 -3.9 0 -3.5 -4.2 01/13/2006 10:30:00 9 0.9 11.5 6.8 9 0.9 11.8 6.8 7.6 1.1 10.3 4.9 293 6 300 165 -4 0 -3.7 -4.2 01/13/2006 10:40:00 9.2 0.9 12.2 6.8 9.1 0.8 11.8 6.8 6.9 1 10.7 4.9 302 6 306 165 -3.7 0.1 -3.5 -3.9 01/13/2006 10:50:00 7.7 1 10.3 5.3 7.7 1 10.3 5.3 6.1 1 8.8 4.2 298 9 297 165 -3.7 0 -3.5 -3.9 01/13/2006 11:00:00 7.4 0.7 8.8 4.9 7.5 0.7 8.8 4.2 6.6 1 9.1 4.2 294 6 282 165 -3.5 0 -3.3 -3.5 01/13/2006 11:10:00 7.9 0.7 9.5 5.7 8 0.7 9.5 6.1 7.4 0.8 9.9 5.3 289 4 288 165 -3.7 0.1 -3.3 -3.9 01/13/2006 11:20:00 7.9 0.8 9.9 4.6 8 0.8 9.9 4.6 7 1 9.1 4.2 294 7 290 165 -3.7 0.2 -3.3 -3.9 01/13/2006 11:30:00 8 0.6 9.5 6.1 8.1 0.6 9.5 6.5 6.8 0.9 8.8 4.6 295 4 295 165 -3.5 0 -3.3 -3.5 01/13/2006 11:40:00 8.4 0.6 9.5 6.8 8.5 0.6 9.5 6.8 7.1 0.8 9.1 4.9 294 4 289 165 -3.5 0 -3.3 -3.7 01/13/2006 11:50:00 8.1 0.6 9.5 6.5 8.2 0.6 9.9 6.5 6.4 0.8 9.1 4.6 297 5 295 165 -3.3 0 -3 -3.5 01/13/2006 12:00:00 7.4 0.9 9.1 5.7 7.5 0.9 9.5 5.7 5.8 0.8 8.8 3.8 303 6 300 165 -3.1 0 -2.8 -3.3 01/13/2006 12:10:00 4.8 1 7.2 3 4.9 1 7.6 3 4.4 0.8 6.8 2.6 311 15 295 165 -2.8 0.1 -2.4 -3 01/13/2006 12:20:00 6 1.3 8.4 3.4 6.1 1.3 8.8 3.4 5.9 1.4 8.8 3 295 9 293 165 -2.8 0.2 -2.4 -3.3 01/13/2006 12:30:00 8 0.6 9.9 6.5 8.1 0.6 9.5 6.5 7.6 0.7 9.5 5.7 288 4 289 165 -3.4 0 -3.3 -3.5 01/13/2006 12:40:00 7.9 0.8 10.3 6.1 8 0.8 10.3 6.1 6.7 1 9.5 4.2 295 6 290 165 -3.2 0.1 -2.8 -3.5 01/13/2006 12:50:00 7.8 0.7 10.7 6.1 7.9 0.7 10.7 6.1 6.5 1 9.5 4.6 302 8 287 165 -3 0 -2.6 -3 01/13/2006 13:00:00 5.1 1 7.2 3 5.3 0.9 7.6 3.4 4.5 0.8 7.2 2.6 303 8 295 165 -2.8 0.3 -2.1 -3 01/13/2006 13:10:00 5 1 7.2 3 5.2 0.9 7.2 3 4.7 0.9 6.5 2.3 293 8 307 165 -2.5 0.1 -2.1 -2.8 01/13/2006 13:20:00 7.7 0.8 9.1 5.3 7.9 0.8 9.5 5.7 7.1 1.1 9.5 4.2 291 5 286 165 -3.3 0.2 -2.8 -3.5 01/13/2006 13:30:00 7.7 0.6 9.1 6.5 7.8 0.6 9.1 6.5 6.6 0.8 9.1 4.6 292 4 290 165 -3.4 0 -3 -3.5 01/13/2006 13:40:00 6.9 0.6 9.1 4.9 7.1 0.6 8.8 4.9 6.6 0.7 8.4 4.2 284 5 291 165 -3.5 0.1 -3.3 -3.5 01/13/2006 13:50:00 7.9 0.6 9.1 6.1 8.1 0.6 9.5 6.5 7.7 0.8 9.5 4.9 287 5 291 165 -3.8 0 -3.5 -3.9 01/13/2006 14:00:00 7.2 0.4 8.4 6.1 7.3 0.4 8.8 6.1 6.7 0.7 8.4 4.6 290 3 287 165 -3.9 0 -3.7 -3.9 01/13/2006 14:10:00 6.9 0.6 8.8 4.9 7 0.6 8.8 4.9 5.4 0.7 7.6 3.4 297 4 299 165 -3.8 0 -3.7 -3.9 01/13/2006 14:20:00 6.1 0.5 7.2 4.6 6.2 0.5 7.2 4.6 5.2 0.8 7.2 3.4 294 5 292 165 -3.7 0.1 -3.5 -3.9 01/13/2006 14:30:00 6.1 0.6 7.6 4.6 6.3 0.6 7.6 4.6 5.1 0.8 7.2 3 292 5 287 165 -3.7 0 -3.5 -3.9 01/13/2006 14:40:00 6.2 0.8 8 3.8 6.4 0.8 8 4.6 5.5 1 8.4 3 292 4 294 165 -3.9 0 -3.5 -4.2 01/13/2006 14:50:00 5.3 0.7 7.2 3 5.6 0.7 7.2 3 4.7 0.9 6.8 2.3 294 6 288 165 -3.7 0.1 -3.5 -3.9 01/13/2006 15:00:00 6.6 0.6 8 4.9 6.8 0.6 8 4.9 5.6 0.9 7.6 3.4 293 4 291 165 -3.8 0 -3.5 -3.9 01/13/2006 15:10:00 5.9 0.6 8 4.6 6.1 0.6 8 4.6 5.5 1 8 3 293 5 290 165 -4 0 -3.9 -4.2 01/13/2006 15:20:00 6.3 0.4 7.2 4.9 6.5 0.4 7.6 4.9 5.9 0.8 8 3.4 293 4 296 165 -4.1 0 -3.9 -4.2 01/13/2006 15:30:00 6.6 0.5 7.6 5.3 6.7 0.5 8 5.3 5.8 0.9 8 3 292 3 282 165 -4.2 0 -3.9 -4.4 01/13/2006 15:40:00 6.5 0.6 8 4.9 6.7 0.6 8 5.3 6 0.9 8 3.4 292 4 282 165 -4 0 -3.7 -4.2 01/13/2006 15:50:00 6.1 0.5 7.6 4.9 6.2 0.5 7.6 4.9 5.1 0.7 7.6 3.4 297 7 300 165 -3.9 0 -3.7 -3.9 01/13/2006 16:00:00 7 0.8 8.8 5.3 7.2 0.7 8.8 5.7 6.4 0.8 8.4 3.8 291 3 286 165 -4.2 0 -3.9 -4.4 01/13/2006 16:10:00 7.1 0.6 8.8 5.3 7.2 0.6 8.8 5.3 6.3 0.8 8.4 3.8 292 5 294 165 -4.3 0 -4.2 -4.4 01/13/2006 16:20:00 5.5 1 8 3 5.5 1 7.6 2.6 4.8 0.7 7.2 3 313 18 299 165 -4.1 0.2 -3.5 -4.4 01/13/2006 16:30:00 5.1 0.8 7.2 3.4 5.1 0.8 7.2 3.4 4.6 0.7 6.5 2.6 306 14 291 165 -3.6 0 -3.5 -3.5 01/13/2006 16:40:00 6 0.5 7.2 4.6 6.1 0.5 7.2 4.6 5.4 0.8 7.2 3.4 292 5 290 165 -3.9 0 -3.5 -4.2 01/13/2006 16:50:00 6.8 0.5 7.6 5.3 7 0.5 8 5.7 7 0.5 8.4 5.3 281 5 285 165 -4.5 0.2 -4.2 -5 01/13/2006 17:00:00 7.5 0.4 8.8 6.1 7.6 0.4 8.8 6.5 7 0.6 8.4 5.3 288 5 296 165 -5 0.1 -4.8 -5.3 01/13/2006 17:10:00 6.8 0.7 8.8 4.9 6.8 0.8 8.4 4.9 5.6 1.2 8 3 293 5 296 165 -5.1 0 -4.8 -5.3 01/13/2006 17:20:00 6.7 0.6 8.4 4.6 6.7 0.7 8.4 4.6 5.1 0.8 7.6 3.4 296 5 294 165 -4.8 0.1 -4.6 -5 01/13/2006 17:30:00 8 0.6 9.5 6.1 8 0.6 9.1 6.5 5.8 0.7 8.4 4.2 298 4 302 165 -4.8 0 -4.6 -5 01/13/2006 17:40:00 7.3 0.8 9.5 5.3 7.3 0.9 9.1 5.3 5.5 0.7 8.8 3.8 303 6 301 165 -4.8 0 -4.6 -5 01/13/2006 17:50:00 5.4 0.7 7.2 3.8 5.3 0.7 7.2 3 5.1 0.8 7.6 3.4 324 11 325 165 -4.9 0.1 -4.6 -5 01/13/2006 18:00:00 5.4 1 7.6 2.6 5.3 1 7.6 2.6 5 0.6 6.8 3.4 329 18 307 165 -4.7 0.1 -4.4 -5 01/13/2006 18:10:00 7.3 0.5 8.4 5.3 7.3 0.5 8.4 5.7 5.4 0.8 7.6 3.8 298 5 301 165 -4.8 0.1 -4.4 -5 01/13/2006 18:20:00 6.6 0.7 8 4.9 6.6 0.7 8.4 4.9 4.8 0.9 7.6 3 299 4 295 165 -4.3 0 -4.2 -4.6 01/13/2006 18:30:00 5.6 0.6 7.2 3.8 5.7 0.7 7.2 3.8 4.5 0.6 6.1 3 305 8 296 165 -4.3 0 -4.2 -4.4 01/13/2006 18:40:00 5.3 0.6 6.5 3 5.3 0.6 6.5 3.8 4.2 0.6 5.7 2.6 305 7 302 165 -4.5 0.1 -4.2 -4.6 01/13/2006 18:50:00 5.5 0.7 6.8 3.8 5.6 0.7 7.2 3.8 4.7 0.8 6.1 2.3 293 6 288 165 -4.4 0.1 -4.2 -4.6 01/13/2006 19:00:00 5.1 1 6.8 3 5.1 0.9 6.8 3 4.1 0.8 5.7 1.9 301 7 298 165 -4.1 0.1 -3.9 -4.4 01/13/2006 19:10:00 4.2 0.5 6.1 2.6 4.3 0.5 6.1 3 3.6 0.6 5.3 2.3 291 7 293 165 -4 0.1 -3.9 -4.4 01/13/2006 19:20:00 5.4 0.5 7.2 4.2 5.5 0.5 7.2 4.2 4.1 0.6 6.1 2.6 296 5 295 165 -4.5 0.1 -3.9 -4.6 01/13/2006 19:30:00 6.1 0.6 7.2 4.2 6.1 0.6 7.6 4.2 4.7 0.8 6.8 2.6 296 5 294 165 -4.6 0 -4.4 -4.6 01/13/2006 19:40:00 5.5 0.5 6.8 4.2 5.5 0.5 6.8 4.6 4.3 0.9 6.5 2.3 297 5 291 165 -4.5 0 -4.4 -4.6 01/13/2006 19:50:00 5.3 0.7 6.8 3.4 5.4 0.7 6.5 3.8 3.9 0.7 5.7 2.3 302 5 301 165 -4.5 0 -4.4 -4.6 01/13/2006 20:00:00 5.1 0.6 6.5 3.8 5.1 0.6 6.5 3.8 4.3 0.6 6.1 2.3 307 7 303 165 -4.2 0 -3.9 -4.4 01/13/2006 20:10:00 5.5 0.6 6.8 4.2 5.5 0.6 6.8 4.2 4.4 0.6 6.1 2.6 306 6 306 165 -4.2 0 -3.9 -4.4 01/13/2006 20:20:00 5.2 0.7 6.8 3.4 5.2 0.7 7.2 3.4 3.9 0.6 6.1 2.6 304 6 319 165 -4.2 0 -3.9 -4.4 01/13/2006 20:30:00 4.9 0.6 6.5 3 5 0.6 6.5 3.4 3.7 0.6 5.3 2.3 299 6 302 165 -4.2 0 -3.9 -4.4 01/13/2006 20:40:00 5 0.6 6.1 3.4 5.1 0.6 6.5 3.4 3.8 0.6 5.3 2.3 297 5 292 165 -4.1 0 -3.9 -4.2 01/13/2006 20:50:00 4.9 0.6 6.5 3 4.9 0.6 6.5 3.4 4.2 0.7 5.7 2.6 290 7 292 165 -4.2 0 -3.9 -4.4 01/13/2006 21:00:00 5.4 0.5 6.8 4.2 5.4 0.5 6.8 4.2 4.3 0.8 6.5 2.6 294 5 291 165 -4.1 0 -3.9 -4.2 01/13/2006 21:10:00 5.3 0.6 6.5 3 5.3 0.6 6.8 3 4.1 0.7 6.1 2.3 295 5 297 165 -4.2 0 -3.9 -4.4 01/13/2006 21:20:00 4.8 0.6 6.5 3 4.8 0.6 6.5 3 3.8 0.6 5.7 2.3 296 5 298 165 -4.1 0 -3.9 -4.2 01/13/2006 21:30:00 4.4 0.7 6.1 2.3 4.3 0.7 5.7 2.3 3.2 0.5 4.9 2.3 301 7 298 165 -4.4 0.2 -3.9 -4.8 01/13/2006 21:40:00 3.5 0.3 4.2 2.6 3.4 0.3 4.2 2.6 3.2 0.3 3.8 2.6 316 6 296 165 -5.2 0.1 -4.8 -5.5 01/13/2006 21:50:00 2.6 0.8 4.6 1.1 2.5 0.8 4.6 1.1 2.1 0.7 4.2 0.7 315 12 310 165 -5 0.1 -4.6 -5.5 01/13/2006 22:00:00 3 0.7 4.6 1.1 3 0.7 4.6 1.5 2.4 0.7 4.2 0.7 305 11 294 165 -5.3 0 -5 -5.5 01/13/2006 22:10:00 4.8 0.5 5.7 3.4 4.9 0.5 5.7 3.4 4.6 0.9 6.1 2.3 283 6 285 165 -4.8 0.1 -4.6 -5 01/13/2006 22:20:00 3.5 0.6 4.9 1.5 3.8 0.5 4.9 2.6 3.9 0.5 4.9 3 261 9 274 165 -4.7 0 -4.6 -4.8 01/13/2006 22:30:00 2.8 0.4 3.8 2.3 3.1 0.4 4.6 2.3 3.1 0.5 4.2 1.9 272 9 255 165 -4.5 0.1 -4.2 -4.6 01/13/2006 22:40:00 2.7 0.4 3.8 1.9 2.9 0.4 3.8 1.9 2.8 0.5 4.2 1.9 279 5 279 165 -4 0 -3.7 -4.4 01/13/2006 22:50:00 3.7 0.4 4.9 2.6 3.8 0.4 4.9 2.6 3.2 0.4 4.2 2.3 291 6 291 165 -4.1 0 -3.9 -4.4 01/13/2006 23:00:00 3.7 0.5 4.9 2.6 3.8 0.5 4.9 2.6 2.6 0.4 3.8 1.5 301 4 305 165 -4.4 0 -4.2 -4.6 01/13/2006 23:10:00 3.1 0.6 4.6 1.9 3.2 0.5 4.6 1.9 2.2 0.4 3.4 1.1 299 4 298 165 -4.5 0.1 -4.4 -4.8 01/13/2006 23:20:00 1.1 0.5 2.3 0.4 1.2 0.5 2.3 0.4 0.9 0.4 1.9 0.4 311 43 311 165 -4.7 0 -4.4 -4.8 01/13/2006 23:30:00 0.6 0.5 1.9 0.4 0.7 0.5 1.9 0.4 0.7 0.4 1.9 0.4 133 15 99 165 -4.5 0 -4.4 -4.6 01/13/2006 23:40:00 1.9 0.4 2.6 0.7 1.8 0.4 2.6 0.7 2 0.3 2.6 0.7 148 5 162 165 -4.7 0.1 -4.4 -5 01/13/2006 23:50:00 2.1 0.4 3 1.5 2 0.4 3 1.5 2.2 0.4 3 1.5 159 3 162 165 -4.9 0 -4.6 -5 01/14/2006 00:00:00 1.4 0.5 3 0.4 1.2 0.6 3.4 0.4 1.3 0.6 3 0.4 201 39 276 165 -4.9 0.1 -4.6 -5 01/14/2006 00:10:00 2.6 0.5 4.2 1.1 3.2 0.4 4.2 2.3 3.1 0.4 3.8 1.5 266 8 281 165 -4.9 0.1 -4.6 -5.3 01/14/2006 00:20:00 3.2 0.4 3.8 2.3 3.3 0.4 4.2 2.3 2.9 0.6 4.2 1.9 294 6 285 165 -4.7 0 -4.4 -5 01/14/2006 00:30:00 1.9 0.6 2.6 0.4 2.1 0.4 3 1.1 2.1 0.5 3 1.1 278 16 295 165 -4.2 0.1 -3.9 -4.4 01/14/2006 00:40:00 1.4 0.5 2.3 0.4 1.7 0.4 2.6 0.7 1.7 0.4 2.6 0.7 203 7 204 165 -3.9 0.1 -3.5 -4.2 01/14/2006 00:50:00 1 0.3 1.5 0.4 1.5 0.3 1.9 0.7 1.5 0.3 1.9 0.7 213 3 210 165 -3.7 0 -3.5 -3.9 01/14/2006 01:00:00 0.8 0.5 1.9 0.4 1.1 0.5 2.3 0.4 1.1 0.5 2.3 0.4 230 56 194 165 -4.2 0.2 -3.5 -4.6 01/14/2006 01:10:00 0.4 0.1 1.1 0.4 0.6 0.3 1.5 0.4 0.8 0.4 1.5 0.4 282 24 229 165 -5 0.2 -4.6 -5.3 01/14/2006 01:20:00 0.4 0.1 1.1 0.4 0.7 0.4 1.5 0.4 0.5 0.3 1.5 0.4 225 15 229 165 -5.4 0 -5.3 -5.7 01/14/2006 01:30:00 0.4 0 0.4 0.4 0.5 0.2 1.1 0.4 0.4 0 0.4 0.4 211 15 165 165 -5.4 0 -5.3 -5.7 01/14/2006 01:40:00 0.4 0 0.7 0.4 0.8 0.2 1.1 0.4 0.7 0.2 1.1 0.4 203 23 225 165 -4.9 0.1 -4.6 -5.3 01/14/2006 01:50:00 0.4 0.1 0.7 0.4 0.5 0.3 1.1 0.4 0.5 0.3 1.1 0.4 216 38 203 165 -4.8 0 -4.6 -5 01/14/2006 02:00:00 0.4 0.1 0.7 0.4 1 0.2 1.5 0.7 0.5 0.2 1.5 0.4 275 8 265 165 -4.5 0.3 -4.2 -5 01/14/2006 02:10:00 0.8 0.3 1.5 0.4 1.3 0.3 1.9 0.7 1.4 0.4 2.3 0.4 323 19 351 165 -4.5 0.2 -3.9 -4.8 01/14/2006 02:20:00 0.5 0.3 1.5 0.4 0.8 0.4 1.9 0.4 1.1 0.5 2.3 0.4 353 6 357 165 -4.9 0 -4.6 -5 01/14/2006 02:30:00 1 0.6 1.9 0.4 1.2 0.6 1.9 0.4 1.1 0.5 1.9 0.4 93 58 125 165 -4.7 0.1 -4.6 -5 01/14/2006 02:40:00 1.4 0.2 1.9 1.1 1.4 0.2 1.9 1.1 1.5 0.2 1.9 1.1 137 0 137 165 -4.8 0 -4.6 -5 01/14/2006 02:50:00 1 0.3 1.5 0.4 1 0.3 1.5 0.4 1 0.2 1.5 0.4 149 7 137 165 -5 0 -4.8 -5 01/14/2006 03:00:00 0.9 0.5 1.9 0.4 0.8 0.6 1.9 0.4 0.9 0.5 1.9 0.4 157 4 164 165 -4.9 0 -4.6 -5 01/14/2006 03:10:00 1.2 0.3 1.9 0.4 1.4 0.3 1.9 0.7 1 0.4 1.9 0.4 165 1 164 165 -4.8 0 -4.6 -5 01/14/2006 03:20:00 0.8 0.6 2.3 0.4 0.9 0.6 2.3 0.4 0.7 0.5 1.9 0.4 165 1 165 165 -4.7 0 -4.4 -4.6 01/14/2006 03:30:00 0.5 0.3 1.5 0.4 0.6 0.3 1.5 0.4 0.4 0.2 1.5 0.4 168 2 165 165 -4.7 0 -4.6 -4.6 01/14/2006 03:40:00 1.4 0.3 1.9 0.7 1.5 0.2 1.9 1.1 1.3 0.2 1.9 0.7 161 5 162 165 -4.7 0 -4.6 -4.8 01/14/2006 03:50:00 2 0.6 3 0.7 2.1 0.5 3 1.1 1.7 0.5 3 1.1 165 3 169 165 -4.6 0 -4.4 -4.6 01/14/2006 04:00:00 3.1 0.5 4.2 2.3 3 0.4 4.2 2.3 2.9 0.5 4.2 1.9 164 3 165 165 -4.3 0 -3.9 -4.4 01/14/2006 04:10:00 3.5 0.3 4.2 2.6 3.3 0.3 3.8 2.6 3.4 0.3 4.2 2.6 169 5 167 165 -3.9 0 -3.7 -4.2 01/14/2006 04:20:00 3.5 0.2 3.8 3 3.4 0.2 3.8 2.6 3.3 0.2 3.8 2.6 164 3 162 165 -3.9 0 -3.7 -3.9 01/14/2006 04:30:00 3.4 0.2 3.8 3 3.3 0.2 3.8 3 3.4 0.2 3.8 3 161 4 167 165 -4 0 -3.7 -4.2 01/14/2006 04:40:00 3.4 0.3 3.8 2.6 3.3 0.3 3.8 2.6 3.5 0.3 4.2 3 161 2 160 165 -4 0 -3.7 -4.2 01/14/2006 04:50:00 3.1 0.4 3.8 1.9 3.1 0.4 3.8 1.9 3.1 0.4 3.8 1.9 161 4 159 165 -3.8 0 -3.5 -3.9 01/14/2006 05:00:00 2.7 0.7 3.8 0.7 2.6 0.6 3.8 0.7 2.6 0.5 3.8 1.1 158 8 163 165 -3.8 0 -3.5 -4.2 01/14/2006 05:10:00 3.5 0.5 4.2 2.3 3.4 0.4 4.2 2.3 3.3 0.4 4.2 1.9 155 7 158 165 -3.7 0 -3.5 -3.9 01/14/2006 05:20:00 3 0.6 4.2 1.5 3 0.6 4.2 1.5 2.9 0.6 4.2 1.9 157 8 159 165 -3.6 0 -3.5 -3.5 01/14/2006 05:30:00 3 0.5 4.2 1.5 3 0.5 3.8 1.9 3 0.4 3.8 1.9 162 6 164 165 -3.5 0 -3.3 -3.5 01/14/2006 05:40:00 3.1 0.4 4.2 2.3 3.1 0.4 4.2 2.3 3.1 0.4 4.2 2.3 160 5 156 165 -3.5 0 -3.3 -3.5 01/14/2006 05:50:00 3 0.5 4.2 1.9 3 0.4 3.8 2.3 2.8 0.4 3.8 2.3 164 4 164 165 -3.4 0 -3.3 -3.5 01/14/2006 06:00:00 3 0.5 3.8 1.9 3.1 0.5 4.2 1.9 3 0.4 4.2 1.9 160 5 161 165 -3.3 0 -3.3 -3.5 01/14/2006 06:10:00 3.4 0.3 3.8 2.3 3.4 0.3 4.2 2.6 3.2 0.3 4.2 2.6 161 3 160 165 -3.2 0 -3 -3.3 01/14/2006 06:20:00 3.9 0.3 4.6 2.6 3.8 0.3 4.6 2.6 3.7 0.4 4.6 2.6 160 3 160 165 -3.3 0 -3 -3.3 01/14/2006 06:30:00 3.1 0.3 4.2 2.3 3.2 0.3 3.8 2.3 3 0.3 4.2 2.3 159 3 164 165 -3.1 0 -3 -3.3 01/14/2006 06:40:00 3 0.4 3.8 2.3 3 0.4 3.8 1.9 3 0.4 4.2 2.3 152 6 153 165 -3 0 -3 -3.3 01/14/2006 06:50:00 3.4 0.4 4.6 2.3 3.3 0.4 4.2 2.3 3.2 0.4 4.2 2.3 154 6 156 165 -3.1 0 -2.8 -3.3 01/14/2006 07:00:00 3.3 0.5 4.2 1.9 3.3 0.5 4.2 1.9 3.2 0.5 4.2 2.3 148 7 154 165 -3.1 0 -3 -3.3 01/14/2006 07:10:00 3.6 0.5 4.9 2.3 3.6 0.5 4.9 2.3 3.4 0.6 4.9 1.9 153 6 150 165 -3.1 0 -3 -3.3 01/14/2006 07:20:00 3.8 0.6 4.9 2.6 3.7 0.5 4.9 2.6 3.6 0.5 4.9 2.6 160 4 160 165 -3.1 0 -3 -3.3 01/14/2006 07:30:00 3.3 0.7 4.6 1.9 3.2 0.6 4.6 1.9 3.2 0.5 4.6 2.3 164 6 164 165 -3.2 0 -2.8 -3.3 01/14/2006 07:40:00 3.4 0.4 4.6 2.3 3.4 0.4 4.6 2.3 3.3 0.4 4.2 2.3 159 5 155 165 -3.2 0 -3 -3.3 01/14/2006 07:50:00 4.1 0.5 5.3 2.6 4 0.5 4.9 3 3.9 0.4 4.9 3 157 6 159 165 -3 0 -2.8 -3.3 01/14/2006 08:00:00 3.9 0.6 4.9 2.3 3.9 0.6 4.9 2.3 3.6 0.5 4.9 2.3 153 5 155 165 -3 0 -2.8 -3.3 01/14/2006 08:10:00 3.7 0.6 4.6 1.9 3.7 0.6 4.9 1.9 3.5 0.6 4.6 2.3 153 7 153 165 -3 0 -2.8 -3 01/14/2006 08:20:00 3.1 0.5 4.2 2.3 3.1 0.4 4.2 2.3 3.1 0.4 4.2 2.3 157 6 156 165 -3 0 -2.8 -3 01/14/2006 08:30:00 3.1 0.5 4.2 2.3 3.1 0.4 4.2 2.3 3 0.5 4.6 1.9 158 6 157 165 -2.9 0 -2.8 -3 01/14/2006 08:40:00 3.4 0.5 4.6 2.3 3.5 0.4 4.6 2.6 3.3 0.4 4.6 2.3 155 6 157 165 -2.9 0 -2.8 -3 01/14/2006 08:50:00 3.1 0.4 3.8 1.9 3.3 0.4 3.8 2.3 3.3 0.4 4.2 2.6 153 6 145 165 -2.8 0 -2.6 -2.8 01/14/2006 09:00:00 3.2 0.4 4.6 2.3 3.4 0.4 4.6 2.3 3.3 0.4 4.6 2.6 149 5 141 165 -2.9 0 -2.6 -3 01/14/2006 09:10:00 4 0.5 4.9 2.6 4.1 0.5 5.3 3 4.2 0.5 4.9 2.6 149 6 156 165 -2.8 0 -2.6 -2.8 01/14/2006 09:20:00 4.1 0.3 4.9 3.4 4.1 0.3 4.9 3.4 4.1 0.3 4.9 3.4 152 5 157 165 -2.8 0 -2.6 -3 01/14/2006 09:30:00 3.7 0.6 4.6 2.3 3.6 0.6 4.6 2.3 3.7 0.6 4.9 2.3 157 5 156 165 -2.8 0 -2.6 -2.8 01/14/2006 09:40:00 4.1 0.7 5.7 2.3 4.1 0.7 5.7 2.3 4.1 0.6 5.7 2.6 158 12 154 165 -2.7 0 -2.6 -2.8 01/14/2006 09:50:00 4.3 0.8 6.5 2.3 4.3 0.8 6.5 2.3 4.3 0.8 6.5 2.6 155 7 150 165 -2.8 0 -2.6 -2.8 01/14/2006 10:00:00 4.8 0.6 6.1 3.4 4.7 0.5 6.1 3.4 4.7 0.5 6.1 3.4 155 5 153 165 -2.8 0 -2.6 -3 01/14/2006 10:10:00 4.8 0.4 5.7 3.4 4.7 0.4 5.7 3.4 4.8 0.4 5.7 3.8 154 5 161 165 -3 0 -2.8 -3 01/14/2006 10:20:00 4.3 0.6 5.7 3 4.3 0.5 6.1 3 4.2 0.4 5.7 3 149 7 154 165 -3 0 -2.8 -3 01/14/2006 10:30:00 4.7 0.7 6.5 3 4.8 0.7 6.5 3 4.7 0.6 5.7 3 145 9 143 165 -2.8 0 -2.6 -3 01/14/2006 10:40:00 4.8 0.6 6.8 3.4 4.9 0.6 6.5 3.4 4.7 0.5 6.5 3.4 146 6 155 165 -2.6 0.1 -2.6 -2.8 01/14/2006 10:50:00 5.7 0.6 7.2 3.8 5.7 0.6 7.2 3.8 5.4 0.5 6.5 3.8 142 4 146 165 -2.5 0 -2.1 -2.6 01/14/2006 11:00:00 4.8 0.6 6.1 3.4 5 0.6 6.5 3.4 5 0.6 6.1 3.8 141 5 143 165 -2.3 0 -2.1 -2.4 01/14/2006 11:10:00 4.1 0.5 5.3 2.6 4.2 0.5 5.3 3 4.2 0.5 5.7 2.6 147 8 141 165 -2.4 0 -2.1 -2.6 01/14/2006 11:20:00 3.7 0.8 5.7 1.1 3.7 0.8 5.7 1.1 3.6 0.8 5.7 1.9 150 11 140 165 -2.4 0 -2.1 -2.6 01/14/2006 11:30:00 2.3 1 4.6 0.4 2.5 0.9 4.6 0.4 2.6 0.8 4.6 0.4 146 27 139 165 -2.1 0.1 -1.9 -2.4 01/14/2006 11:40:00 1.7 0.8 4.2 0.4 2.1 0.8 4.6 0.4 1.9 0.8 3.8 0.4 163 28 159 165 -1.9 0 -1.7 -2.1 01/14/2006 11:50:00 1.6 0.8 3.8 0.4 1.9 0.7 3.8 0.4 1.5 0.8 3.4 0.4 161 26 165 165 -1.7 0 -1.4 -1.9 01/14/2006 12:00:00 1.2 0.9 3.8 0.4 1.5 0.9 3.8 0.4 1.2 0.8 3.4 0.4 169 12 183 165 -1.4 0 -1.2 -1.7 01/14/2006 12:10:00 2 0.8 4.6 0.4 2.3 0.7 4.6 0.7 1.9 0.7 3.8 0.4 179 11 178 165 -1.2 0 -1 -1.4 01/14/2006 12:20:00 3.3 0.5 4.6 1.9 3.4 0.5 4.6 1.9 3.2 0.5 4.6 1.9 174 8 164 165 -1 0 -0.8 -1.2 01/14/2006 12:30:00 1.9 0.7 3.4 0.4 2.2 0.6 3.8 1.1 1.5 0.7 3 0.4 213 14 197 165 -0.9 0 -0.5 -1.2 01/14/2006 12:40:00 2.8 0.5 3.8 1.5 3 0.4 3.8 1.5 2.5 0.4 3.4 1.1 195 11 206 165 -0.5 0.1 -0.3 -0.8 01/14/2006 12:50:00 2.9 0.8 5.7 1.1 3 0.7 5.3 1.5 2.6 0.5 4.2 0.7 180 11 200 165 -0.6 0 -0.3 -0.8 01/14/2006 13:00:00 4.5 1 7.2 2.3 4.6 0.9 6.8 2.3 4.2 0.9 6.8 1.9 190 9 199 165 -0.5 0 -0.3 -0.8 01/14/2006 13:10:00 4.3 0.8 6.5 1.5 4.4 0.8 6.5 1.9 3.8 0.7 6.1 2.6 197 10 202 165 -0.3 0 -0.1 -0.5 01/14/2006 13:20:00 4.5 0.7 6.8 3 4.6 0.7 6.5 3 3.9 0.6 5.7 2.6 204 11 187 165 -0.2 0 0.2 -0.3 01/14/2006 13:30:00 5.1 0.7 6.8 3.4 5.3 0.7 7.2 3.8 4.8 0.6 7.2 3 204 7 204 165 0.3 0.2 0.9 -0.1 01/14/2006 13:40:00 4.2 0.8 6.1 2.3 4.3 0.8 6.5 2.6 4.2 0.8 6.1 2.6 195 8 201 165 0.7 0 0.9 0.7 01/14/2006 13:50:00 3.8 0.5 5.3 2.6 3.9 0.5 5.3 2.6 3.7 0.5 5.3 2.3 198 8 193 165 0.6 0 0.9 0.4 01/14/2006 14:00:00 4.5 0.6 5.7 3 4.5 0.6 5.7 3 4.4 0.7 5.7 2.6 188 3 188 165 0.9 0 1.1 0.7 01/14/2006 14:10:00 3.6 0.4 4.6 2.3 3.6 0.4 4.6 2.3 3.2 0.4 4.2 1.9 188 4 187 165 1 0 1.4 0.9 01/14/2006 14:20:00 4.2 0.4 4.9 3 4.1 0.4 4.9 3 4.1 0.5 4.9 3 178 4 179 165 1.2 0 1.4 1.1 01/14/2006 14:30:00 4.4 0.9 6.1 1.9 4.4 0.9 6.1 1.9 4 0.8 5.7 1.1 189 8 192 165 1.3 0.2 1.8 0.9 01/14/2006 14:40:00 4.1 0.6 5.7 1.5 4.1 0.6 5.3 1.9 3.9 0.5 4.9 1.9 181 9 165 165 1.7 0 1.8 1.6 01/14/2006 14:50:00 4.8 0.7 6.8 3.8 4.7 0.7 6.8 3.8 4.3 0.5 5.7 3 180 6 185 165 1.5 0.1 1.6 1.4 01/14/2006 15:00:00 4.7 0.8 7.6 2.6 4.7 0.8 7.6 3 4.3 0.9 7.2 2.3 193 10 198 165 1.8 0.2 2.3 1.4 01/14/2006 15:10:00 5.4 0.6 6.8 3.8 5.4 0.6 6.8 3.8 5.3 0.7 6.8 3 195 9 196 165 2.6 0 2.8 2.3 01/14/2006 15:20:00 4.7 0.6 6.1 3 4.6 0.6 6.5 2.6 4.6 0.6 6.8 3.4 177 13 164 165 2.4 0.4 3 1.8 01/14/2006 15:30:00 4.8 0.5 6.1 3.8 4.7 0.5 6.1 3.8 4.3 0.5 5.7 3 179 6 185 165 1.4 0.1 1.8 1.4 01/14/2006 15:40:00 4.7 0.5 5.7 3 4.5 0.4 5.7 3 4.3 0.4 5.3 3.4 178 4 184 165 1.4 0 1.4 1.4 01/14/2006 15:50:00 3.3 0.6 4.6 1.5 3.3 0.5 4.6 1.9 3 0.5 4.2 1.5 176 6 182 165 1.4 0 1.4 1.4 01/14/2006 16:00:00 3.3 0.6 4.9 1.5 3.3 0.5 4.6 1.9 3 0.6 4.9 1.5 180 6 184 165 1.3 0 1.4 1.1 01/14/2006 16:10:00 4.5 1 6.5 2.3 4.6 1 6.5 2.6 4.2 1 6.1 2.6 194 9 199 165 1.3 0 1.6 1.1 01/14/2006 16:20:00 5.5 0.4 6.5 4.6 5.5 0.4 6.5 4.6 5.5 0.4 6.5 4.2 196 5 201 165 1.8 0 1.8 1.6 01/14/2006 16:30:00 4.2 0.5 5.7 3.4 4.2 0.5 5.7 3 4 0.5 4.9 3 186 4 184 165 1.7 0 1.8 1.4 01/14/2006 16:40:00 3.8 0.3 4.9 3 3.7 0.3 4.6 2.6 3.6 0.3 4.2 2.6 173 6 180 165 1.4 0 1.6 1.4 01/14/2006 16:50:00 3.3 0.5 4.6 1.9 3.3 0.4 4.2 1.9 3.1 0.5 4.2 1.9 173 6 175 165 1.4 0 1.4 1.4 01/14/2006 17:00:00 3.7 0.2 4.2 3 3.6 0.2 4.2 3 3.7 0.3 4.6 2.6 166 8 172 165 1.3 0 1.6 1.4 01/14/2006 17:10:00 4.5 0.6 6.1 3.8 4.4 0.5 6.1 3.8 4.4 0.4 6.1 3.8 171 4 173 165 1.4 0 1.6 1.4 01/14/2006 17:20:00 6.5 0.9 8.4 4.6 6.3 0.8 8 4.6 6.5 0.9 8.8 4.6 170 6 173 165 1.8 0 1.8 1.6 01/14/2006 17:30:00 7.1 0.8 9.5 4.9 7 0.8 9.1 4.9 7 0.8 9.1 5.3 164 6 169 165 1.7 0 1.8 1.4 01/14/2006 17:40:00 7.5 0.6 9.1 5.7 7.2 0.6 8.8 5.3 7.6 0.6 9.5 5.7 167 11 165 165 1.7 0 1.8 1.6 01/14/2006 17:50:00 6.1 0.7 7.6 4.6 5.9 0.7 7.2 4.2 6.3 0.7 7.6 4.9 171 5 165 165 1.8 0 1.8 1.6 01/14/2006 18:00:00 4.7 0.5 5.7 3 4.5 0.5 5.7 3 4.8 0.6 6.1 3.4 171 9 175 165 1.9 0 1.8 1.8 01/14/2006 18:10:00 4.5 0.4 5.3 3.8 4.4 0.3 4.9 3.4 4.5 0.4 5.3 3.4 177 5 180 165 1.9 0 2.1 1.8 01/14/2006 18:20:00 4.2 0.4 5.3 3 4 0.4 4.9 3 4.2 0.4 5.3 3.4 177 5 181 165 1.9 0 1.8 1.8 01/14/2006 18:30:00 3.8 0.3 4.6 3 3.7 0.3 4.6 3 3.9 0.4 4.9 3 170 4 173 165 1.8 0 1.8 1.8 01/14/2006 18:40:00 4 0.5 5.3 2.6 3.8 0.5 4.9 2.6 4.1 0.5 5.7 3 171 7 180 165 1.9 0 1.8 1.8 01/14/2006 18:50:00 3.2 0.3 3.8 2.6 3.1 0.3 3.8 2.6 3.2 0.3 3.8 2.6 167 6 171 165 1.9 0 1.8 1.8 01/14/2006 19:00:00 3.1 0.3 3.8 2.3 3.1 0.3 3.8 2.3 3.1 0.3 3.8 2.6 168 10 179 165 1.8 0 1.8 1.6 01/14/2006 19:10:00 3 0.3 3.4 1.9 2.9 0.3 3.8 1.9 3.1 0.3 3.8 2.3 157 4 165 165 1.8 0 1.8 1.6 01/14/2006 19:20:00 3.5 0.3 4.2 2.6 3.5 0.3 4.2 2.6 3.6 0.3 4.2 2.6 150 5 138 165 1.8 0 1.8 1.6 01/14/2006 19:30:00 2.7 0.3 3.8 2.3 2.8 0.3 3.8 2.3 2.8 0.3 3.8 2.3 158 5 153 165 1.7 0 1.8 1.6 01/14/2006 19:40:00 3.5 0.9 6.5 1.9 3.5 0.8 6.1 1.9 3.5 0.8 6.1 1.5 151 12 171 165 1.8 0 1.8 1.6 01/14/2006 19:50:00 3.5 0.4 4.9 2.3 3.6 0.4 4.6 2.3 3.8 0.4 4.9 2.3 154 11 159 165 1.8 0 1.8 1.6 01/14/2006 20:00:00 4.4 0.5 6.1 3.4 4.5 0.5 6.1 3.4 4.6 0.5 6.1 3.8 152 5 144 165 1.8 0 1.8 1.6 01/14/2006 20:10:00 4.9 0.3 5.7 4.2 4.9 0.3 5.7 4.2 5.3 0.3 5.7 4.2 151 2 154 165 1.8 0 1.8 1.6 01/14/2006 20:20:00 5.2 0.4 6.1 4.6 5.2 0.4 6.1 4.6 5.5 0.3 6.5 4.6 152 3 153 165 1.7 0 1.8 1.6 01/14/2006 20:30:00 6.1 0.8 8 4.6 6 0.7 8 4.6 6.3 0.7 8.4 4.9 150 4 145 165 1.7 0 1.8 1.6 01/14/2006 20:40:00 6.4 0.8 8 4.6 6.3 0.7 8 4.2 6.6 0.8 8 4.2 153 6 151 165 1.8 0 1.8 1.6 01/14/2006 20:50:00 6.4 1 9.1 4.9 6.4 0.9 9.1 4.6 6.6 0.9 9.9 4.9 150 10 128 165 1.8 0 1.8 1.6 01/14/2006 21:00:00 7.8 0.7 10.3 6.5 7.9 0.7 10.3 6.5 8.1 0.8 10.7 6.1 153 5 148 165 1.7 0 1.8 1.6 01/14/2006 21:10:00 7.8 0.9 9.5 5.7 7.8 0.8 9.1 6.1 8.1 0.8 9.9 6.5 148 4 150 165 1.7 0 1.8 1.6 01/14/2006 21:20:00 9.1 1 11.1 6.8 9.1 1 11.1 6.8 9.4 1 11.5 7.2 147 4 144 165 1.8 0 1.8 1.6 01/14/2006 21:30:00 10 0.8 11.8 7.2 10.1 0.8 12.2 7.6 10.4 0.9 12.6 8 149 5 140 165 1.8 0 1.8 1.6 01/14/2006 21:40:00 10.1 0.7 11.8 8.4 10.1 0.6 11.5 8 10.7 0.8 12.6 8.4 154 4 157 165 1.8 0 1.8 1.6 01/14/2006 21:50:00 10.2 0.8 12.2 8.4 10.1 0.8 12.2 8.4 10.7 1 13 8.4 152 3 146 165 1.7 0 1.8 1.6 01/14/2006 22:00:00 9.9 0.7 11.8 8.4 9.9 0.7 11.8 8.4 10.3 0.8 12.6 8 151 2 149 165 1.6 0 1.8 1.6 01/14/2006 22:10:00 8 0.7 9.5 6.5 8 0.7 9.5 6.5 8.3 0.7 9.9 6.5 151 0 151 165 1.7 0 1.8 1.6 01/14/2006 22:20:00 8.1 0.7 9.9 6.5 8.2 0.7 9.9 6.5 8.5 0.8 10.7 6.5 151 0 151 165 1.7 0 1.8 1.6 01/14/2006 22:30:00 8.7 0.5 9.9 7.2 8.7 0.5 9.9 7.2 9.2 0.6 10.7 7.6 151 0 151 165 1.6 0 1.8 1.6 01/14/2006 22:40:00 7.9 0.5 9.1 6.5 8.1 0.5 9.5 6.8 8.3 0.6 9.9 6.8 151 0 151 165 1.6 0 1.8 1.6 01/14/2006 22:50:00 8.2 0.8 10.3 6.5 8.2 0.9 10.7 6.5 8.6 1 11.1 6.8 151 0 151 165 1.6 0 1.8 1.6 01/14/2006 23:00:00 7.3 0.5 8.8 6.1 7.4 0.4 8.8 6.1 7.7 0.5 9.1 6.1 151 0 151 165 1.5 0 1.6 1.4 01/14/2006 23:10:00 7 0.8 8.8 5.7 7.1 0.8 9.1 5.7 7.5 0.8 9.5 5.7 151 0 151 165 1.5 0 1.6 1.4 01/14/2006 23:20:00 7.6 1.5 10.3 4.6 7.8 1.5 10.7 4.9 8.2 1.7 11.5 5.3 151 0 151 165 1.5 0 1.6 1.4 01/14/2006 23:30:00 7.7 0.7 9.5 6.1 8 0.7 9.9 6.1 8.1 0.9 10.3 6.1 151 0 151 165 1.5 0 1.6 1.4 01/14/2006 23:40:00 7.3 0.6 9.1 6.1 7.6 0.6 9.5 6.1 7.9 0.6 9.9 6.1 151 0 151 165 1.5 0 1.6 1.4 01/14/2006 23:50:00 8 0.7 10.3 6.1 8.2 0.7 10.3 6.5 8.5 0.9 10.7 5.7 151 0 151 165 1.5 0 1.6 1.4 01/15/2006 00:00:00 7.1 0.5 8.4 5.7 7.3 0.5 8.8 5.7 7.7 0.5 9.1 6.5 151 0 151 165 1.5 0 1.6 1.4 01/15/2006 00:10:00 6.1 0.9 8.8 4.6 6.4 0.9 9.1 4.6 6.6 0.9 9.5 4.9 151 0 151 165 1.5 0 1.8 1.4 01/15/2006 00:20:00 8 1.1 11.1 5.7 8.4 1.1 11.5 6.1 8.6 1.2 11.8 6.1 151 0 151 165 1.6 0 1.8 1.4 01/15/2006 00:30:00 8.1 1.3 10.7 5.7 8.3 1.3 11.1 5.7 8.8 1.5 11.8 6.1 151 0 151 165 1.6 0 1.6 1.4 01/15/2006 00:40:00 7.5 1.3 10.7 5.3 7.8 1.3 11.1 5.7 7.9 1.3 11.5 5.3 151 0 151 165 1.6 0 1.8 1.6 01/15/2006 00:50:00 7.3 1.2 10.3 4.9 7.6 1.2 9.9 4.9 7.9 1.4 11.1 5.3 151 0 151 165 1.6 0 1.8 1.6 01/15/2006 01:00:00 9.2 1 11.5 6.5 9.5 1 11.8 6.5 9.8 1.2 12.6 6.1 151 0 151 165 1.6 0 1.8 1.6 01/15/2006 01:10:00 8 1.4 11.5 5.7 8.4 1.3 12.2 5.7 8.5 1.4 12.2 6.1 151 0 151 165 1.7 0 1.8 1.6 01/15/2006 01:20:00 9.7 1 11.8 6.8 10.2 1 12.6 7.6 10.5 1.1 13 6.5 151 0 151 165 1.6 0 1.8 1.6 01/15/2006 01:30:00 10.3 1.2 13 6.5 10.8 1.2 13.3 6.8 11.1 1.5 14.1 7.2 151 0 151 165 1.7 0 1.8 1.6 01/15/2006 01:40:00 10.8 1.3 13 7.6 11.2 1.3 13.3 8.8 11.6 1.5 14.5 8 151 0 151 165 1.6 0 1.8 1.6 01/15/2006 01:50:00 10.9 1 14.5 8 11.3 1.1 15.3 8.8 11.5 1.3 15.3 7.6 151 0 151 165 1.6 0 1.8 1.6 01/15/2006 02:00:00 10.7 1 13 7.6 11.1 1 13.3 8.4 11.5 1.3 14.1 7.6 151 0 151 165 1.6 0 1.8 1.6 01/15/2006 02:10:00 10.9 0.9 13 8.4 11.4 0.9 13.3 9.1 12 1 14.5 9.5 151 0 151 165 1.6 0 1.8 1.6 01/15/2006 02:20:00 11.3 0.9 13.3 8.8 11.7 1 13.7 9.1 12.2 1 15.6 9.1 151 0 151 165 1.6 0 1.8 1.4 01/15/2006 02:30:00 10.8 1 13.7 7.6 11.3 1.1 14.1 8 11.5 1.3 14.9 7.2 151 0 151 165 1.5 0 1.8 1.6 01/15/2006 02:40:00 9.9 1.5 13.3 6.8 10.4 1.5 13.7 7.6 10.6 1.7 14.1 7.2 151 0 151 165 1.6 0 1.8 1.6 01/15/2006 02:50:00 9.8 1.4 14.1 7.2 10.2 1.5 14.5 7.6 10.6 1.7 15.3 6.8 151 0 151 165 1.6 0 1.6 1.4 01/15/2006 03:00:00 11.1 0.9 13 8.8 11.6 1 13.7 9.1 11.9 1.2 14.5 8.8 151 0 151 165 1.6 0 1.8 1.6 01/15/2006 03:10:00 10.1 0.9 12.2 7.6 10.6 0.9 12.6 8.4 10.9 1.1 13.7 7.6 151 0 151 165 1.6 0 1.8 1.6 01/15/2006 03:20:00 9.8 1.1 12.6 7.2 10.3 1.1 13 7.6 10.7 1.2 13.7 6.8 151 0 151 165 1.6 0 1.8 1.6 01/15/2006 03:30:00 10.8 1 12.6 8.4 11.2 1 13.3 8.4 11.7 1.2 13.7 8 151 0 150 165 1.6 0 1.8 1.6 01/15/2006 03:40:00 10.1 1.2 14.1 7.2 10.6 1.1 14.5 8 10.9 1.4 16.1 7.2 151 0 151 165 1.7 0 1.8 1.6 01/15/2006 03:50:00 9.9 1 14.5 7.2 10.4 1 14.9 8 10.5 1.2 14.5 7.2 151 0 151 165 1.7 0 1.8 1.6 01/15/2006 04:00:00 10.9 1.9 15.3 6.8 11.3 1.8 16.1 7.2 11.8 2.3 17.6 6.5 151 0 151 165 1.7 0 1.8 1.6 01/15/2006 04:10:00 11.4 2 14.5 7.2 11.7 1.9 15.3 7.6 12 2.3 16.4 6.8 151 0 150 165 1.7 0 1.8 1.6 01/15/2006 04:20:00 11.6 1.3 15.3 8 12 1.3 15.3 8.4 12.1 1.6 16.4 8 150 0 151 165 1.7 0 1.8 1.6 01/15/2006 04:30:00 10.6 1.3 14.1 7.2 11 1.3 14.1 7.6 10.9 1.5 15.3 7.6 150 0 150 165 1.8 0 1.8 1.6 01/15/2006 04:40:00 11 1.7 16.4 7.2 11.6 1.7 17.2 7.6 11.5 1.7 17.6 8 150 0 150 165 1.9 0 1.8 1.8 01/15/2006 04:50:00 12.7 1.5 15.6 9.1 13.2 1.5 16.1 9.5 13.1 1.7 16.8 8.4 150 0 150 165 1.8 0 2.1 1.6 01/15/2006 05:00:00 11 1.1 14.1 7.2 11.5 1.1 14.9 8 11.4 1.1 14.1 8 150 0 150 165 1.8 0 1.8 1.6 01/15/2006 05:10:00 11.6 1.3 15.3 8.8 12.2 1.3 16.1 9.1 11.8 1.5 16.1 8.4 150 0 150 165 1.9 0 1.8 1.8 01/15/2006 05:20:00 12.3 1.2 16.1 9.9 12.9 1.2 16.4 9.9 12.5 1.3 17.2 9.1 150 0 150 165 1.9 0 2.1 1.8 01/15/2006 05:30:00 12.4 1.3 16.4 9.1 13 1.4 16.8 9.5 12.3 1.5 17.6 8.8 150 0 150 165 1.9 0 2.3 1.8 01/15/2006 05:40:00 11.6 1.5 15.6 8.8 12.2 1.5 16.1 9.1 11.7 1.7 15.3 8.4 150 0 150 165 2.1 0 2.3 1.8 01/15/2006 05:50:00 12.4 1.2 15.3 9.1 13 1.2 16.1 9.5 12.2 1.2 16.1 9.1 150 0 150 165 2.2 0 2.3 2.1 01/15/2006 06:00:00 11.5 1.6 15.3 7.2 12 1.6 16.1 8 11.5 1.6 16.1 7.6 150 0 150 165 2.3 0 2.6 2.3 01/15/2006 06:10:00 12 1.4 15.6 7.6 12.5 1.5 16.1 7.6 11.9 1.5 14.9 7.2 149 0 149 165 2 0 2.3 1.8 01/15/2006 06:20:00 13.6 1.5 17.6 9.9 14.1 1.6 18.3 9.9 13.3 1.7 18.3 9.5 149 0 149 165 2.2 0 2.6 2.1 01/15/2006 06:30:00 14.3 1.3 18.7 10.7 14.7 1.4 19.1 10.7 14.1 1.5 18.7 10.7 149 0 149 165 2.3 0 2.6 2.3 01/15/2006 06:40:00 12.5 1.2 16.1 9.1 12.8 1.2 16.8 9.5 12.3 1.2 15.6 9.5 149 0 149 165 2.4 0 2.6 2.3 01/15/2006 06:50:00 12.6 2.3 19.9 8.4 13 2.3 19.9 8.4 12.4 2.4 20.2 7.2 149 0 149 165 2.4 0 2.8 2.1 01/15/2006 07:00:00 12 2.2 16.8 8.4 12.2 2.2 17.2 8.4 11.8 2.1 17.2 7.6 149 0 149 165 2 0 2.3 1.8 01/15/2006 07:10:00 12.5 2.6 17.9 6.8 12.8 2.6 18.7 6.8 12.2 2.7 17.6 6.5 149 0 149 165 2 0 2.3 1.8 01/15/2006 07:20:00 12.4 1.4 16.1 8.8 12.6 1.4 16.1 8.8 12.1 1.5 15.3 8.4 149 0 149 165 2 0 2.3 1.8 01/15/2006 07:30:00 10.6 1.4 13.7 6.8 10.7 1.4 14.1 7.6 10.4 1.3 13.3 7.2 149 0 149 165 2 0 2.3 1.8 01/15/2006 07:40:00 10 1.5 14.9 5.7 10.3 1.5 15.3 6.1 9.9 1.5 15.6 6.1 149 0 149 165 2 0 2.3 1.8 01/15/2006 07:50:00 10.9 1.7 15.6 7.2 11.2 1.7 16.1 7.6 10.4 1.9 16.1 6.8 149 0 149 165 2.1 0 2.3 1.8 01/15/2006 08:00:00 13.2 2 19.1 8 13.4 2.1 19.5 7.6 12.9 2.1 19.5 8 149 0 149 165 2.3 0 2.6 2.3 01/15/2006 08:10:00 11.6 1.6 16.4 7.2 11.7 1.6 16.4 7.2 11.1 1.8 16.1 6.1 149 0 149 165 2.1 0 2.3 2.1 01/15/2006 08:20:00 12 1.5 15.3 8.8 12.1 1.5 15.6 8.4 11.6 1.6 16.1 7.6 149 0 149 165 2.2 0 2.3 2.1 01/15/2006 08:30:00 12.6 1.7 17.2 7.6 12.7 1.7 16.4 7.6 12.1 1.9 16.1 6.5 149 0 149 165 2.3 0 2.6 2.3 01/15/2006 08:40:00 12.3 1.7 16.8 7.2 12.5 1.7 16.8 8 11.9 1.8 16.4 6.8 149 0 149 165 2.4 0 2.6 2.3 01/15/2006 08:50:00 13.1 2.1 18.7 8 13.2 2.1 18.3 8.8 12.7 2.3 17.9 8 149 0 149 165 2.4 0 2.6 2.3 01/15/2006 09:00:00 13.2 2.2 17.6 8.4 13.3 2.2 17.6 8.4 12.8 2.3 17.6 7.2 149 0 149 165 2.4 0 2.6 2.3 01/15/2006 09:10:00 13.8 1.5 18.7 9.9 13.9 1.5 19.5 9.9 13.4 1.7 17.9 9.1 149 0 149 165 2.1 0.1 2.6 1.8 01/15/2006 09:20:00 12.8 1.7 17.2 7.6 13 1.7 17.2 8.4 12.3 1.7 16.8 7.2 149 0 149 165 2.2 0 2.3 2.1 01/15/2006 09:30:00 11.7 1.2 15.3 8.4 11.9 1.3 15.6 8 11.6 1.4 15.3 8.4 149 0 149 165 2.3 0 2.6 2.3 01/15/2006 09:40:00 13.1 2 17.6 8.4 13.4 2.1 17.9 8.4 13.3 2.3 18.3 7.2 149 0 149 165 2.4 0 2.6 2.3 01/15/2006 09:50:00 11.1 1.9 16.4 7.2 11.4 2 16.8 7.2 11.2 2.1 16.8 6.5 149 0 149 165 2.3 0 2.6 2.3 01/15/2006 10:00:00 11.9 1.7 16.8 8 12.2 1.8 17.2 7.6 11.8 2.1 16.4 7.6 149 0 149 165 2.3 0 2.6 2.3 01/15/2006 10:10:00 12 1.3 14.9 8 12.2 1.3 15.3 7.2 12 1.6 15.6 7.2 149 0 149 165 2.2 0 2.6 2.1 01/15/2006 10:20:00 12.8 2 16.4 7.6 13 2 16.8 8.8 12.5 2.2 16.8 7.2 149 0 149 165 2.3 0 2.6 2.3 01/15/2006 10:30:00 13 1.8 18.3 8.8 13.3 1.8 19.1 8.8 12.9 2 18.3 8 149 0 149 165 2.3 0 2.6 2.3 01/15/2006 10:40:00 12.5 1.8 16.8 8 12.8 1.8 17.2 8.4 12.6 1.9 17.2 8 149 0 149 165 2.3 0 2.6 2.3 01/15/2006 10:50:00 12.6 2 17.6 7.6 12.8 2 17.9 8 12.4 2 17.9 7.2 149 0 149 165 2 0 2.3 1.8 01/15/2006 11:00:00 13.1 2 17.6 7.6 13.4 2 17.9 7.6 12.9 2.1 17.9 7.6 149 0 149 165 2.2 0 2.6 2.3 01/15/2006 11:10:00 12.7 1.7 16.1 8 13 1.7 16.4 8.4 12.4 1.9 16.8 8.8 149 0 149 165 2.1 0 2.3 2.1 01/15/2006 11:20:00 11.8 1.5 16.1 7.2 12 1.5 16.4 7.2 11.4 1.7 16.8 7.6 149 0 149 165 2.3 0 2.6 2.3 01/15/2006 11:30:00 12.8 1.7 17.6 7.2 13.1 1.8 17.9 8.4 12.5 1.8 17.6 8.8 149 0 149 165 2.3 0 2.6 2.1 01/15/2006 11:40:00 14.5 1.7 17.9 9.5 14.9 1.6 18.3 9.5 14.3 1.7 17.9 9.1 149 0 149 165 2.3 0 2.6 2.1 01/15/2006 11:50:00 13.1 1.4 16.4 9.1 13.4 1.4 16.4 9.5 13.1 1.5 16.4 8.8 149 0 149 165 2.3 0 2.6 2.1 01/15/2006 12:00:00 13 2 17.6 8.4 13.3 2 17.6 8.4 12.8 2.2 17.6 8 149 0 148 165 2 0 2.3 1.8 01/15/2006 12:10:00 13.3 1.9 17.6 6.8 13.6 2 17.9 7.2 13.1 2 18.3 6.8 149 0 149 165 1.9 0 2.1 1.8 01/15/2006 12:20:00 12.5 1.7 17.2 8.4 12.9 1.7 17.2 9.1 12.5 1.8 17.2 7.2 149 0 149 165 1.8 0 1.8 1.6 01/15/2006 12:30:00 13.4 2.1 17.6 8 13.7 2.1 18.3 8 13.2 2.2 17.9 8 149 0 148 165 1.7 0 1.8 1.6 01/15/2006 12:40:00 13.4 1.6 16.4 8.4 13.7 1.6 16.8 8.8 13.2 1.7 16.8 8.4 149 0 149 165 1.6 0 1.8 1.6 01/15/2006 12:50:00 12.8 2 17.9 8.4 13 2.1 18.3 8.4 12.4 2.2 17.6 7.2 149 0 149 165 1.6 0 1.8 1.6 01/15/2006 13:00:00 12.2 1.8 16.1 6.8 12.4 1.8 16.4 7.6 11.9 1.9 16.1 7.2 149 0 149 165 1.6 0 1.8 1.4 01/15/2006 13:10:00 12.8 1.4 16.4 8.4 13.2 1.4 16.4 8.8 12.7 1.6 16.4 8.8 149 0 148 165 1.6 0 1.8 1.6 01/15/2006 13:20:00 12.6 1.5 16.1 8 13 1.6 16.4 8.8 12.5 1.7 16.4 8 148 0 148 165 1.7 0 1.8 1.6 01/15/2006 13:30:00 13.5 1.5 17.2 9.5 14.1 1.5 18.3 9.5 13.4 1.7 17.9 9.1 148 0 148 165 1.7 0 1.8 1.6 01/15/2006 13:40:00 12.4 2 16.8 6.8 12.9 2.1 17.6 6.5 12.3 2.3 17.2 6.8 148 0 148 165 1.7 0 1.8 1.6 01/15/2006 13:50:00 13.3 1.7 16.8 8 13.9 1.8 17.6 8.4 13.1 1.9 17.6 8 148 0 148 165 1.7 0 1.8 1.6 01/15/2006 14:00:00 12.3 1.3 15.6 7.6 12.8 1.5 16.1 8 11.8 1.7 15.6 7.6 148 0 148 165 1.7 0 1.8 1.6 01/15/2006 14:10:00 12.1 1.8 16.1 7.2 12.7 1.9 17.2 7.6 11.9 1.8 16.1 7.6 148 0 148 165 1.7 0 1.8 1.6 01/15/2006 14:20:00 13.4 2.4 17.6 7.6 14 2.5 18.7 8 13.2 2.5 18.3 7.2 148 0 148 165 1.6 0 1.8 1.6 01/15/2006 14:30:00 14.1 1.6 19.5 8.8 14.7 1.7 20.2 8.8 13.9 1.8 19.9 9.1 148 0 148 165 1.6 0 1.8 1.6 01/15/2006 14:40:00 13.5 1.9 18.3 9.1 14 1.9 18.7 9.9 13.2 1.9 17.9 8.8 148 0 147 165 1.7 0 1.8 1.6 01/15/2006 14:50:00 13 1.6 16.8 8.8 13.4 1.7 17.9 9.5 12.6 1.7 16.8 8.8 147 0 147 165 1.7 0 1.8 1.6 01/15/2006 15:00:00 12.8 2.1 17.6 8.4 13.3 2.2 18.3 8.4 12.7 2.1 19.1 7.6 147 0 147 165 1.7 0 1.8 1.6 01/15/2006 15:10:00 13.9 1.6 17.2 9.1 14.5 1.7 17.9 9.5 13.8 1.7 18.3 9.1 146 1 145 165 1.7 0 1.8 1.6 01/15/2006 15:20:00 13.4 2.3 19.1 8 14.2 2.3 19.9 8.4 13 2.1 17.9 8 108 22 96 165 1.8 0 1.8 1.8 01/15/2006 15:30:00 14 1.7 19.5 9.1 14.5 1.7 20.2 9.1 13.3 1.7 18.3 9.5 92 8 98 165 1.8 0 1.8 1.6 01/15/2006 15:40:00 13.3 1.7 16.8 9.1 13.7 1.8 17.6 8.4 12.6 1.7 16.8 8.8 93 8 89 165 1.8 0 1.8 1.6 01/15/2006 15:50:00 12.8 1.8 17.6 8.4 13.2 1.9 17.9 8.4 12.2 1.7 17.2 8.4 91 9 87 165 1.8 0 1.8 1.6 01/15/2006 16:00:00 14.1 1.7 17.6 9.5 14.6 1.8 17.9 9.9 13.5 1.9 18.3 8.4 94 8 91 165 1.8 0 1.8 1.6 01/15/2006 16:10:00 14.3 1.9 18.7 8 14.7 2 19.1 8.4 13.7 2 17.6 8.4 93 7 94 165 1.8 0 1.8 1.6 01/15/2006 16:20:00 13.8 1.9 17.9 8.4 14.2 1.9 18.7 8.4 13.2 2 17.2 8.4 93 8 102 165 1.8 0 1.8 1.6 01/15/2006 16:30:00 13.4 1.8 18.3 8 13.8 1.9 19.1 8.4 12.7 1.9 17.6 7.2 91 7 90 165 1.8 0 1.8 1.6 01/15/2006 16:40:00 12.5 1.8 16.8 8.4 12.8 1.8 17.2 8.8 11.8 1.9 16.4 8 87 8 88 165 1.7 0 1.8 1.6 01/15/2006 16:50:00 13.3 2.1 18.3 8 13.6 2.2 18.3 7.6 12.6 2 17.2 8.4 91 8 90 165 1.9 0 1.8 1.8 01/15/2006 17:00:00 13.6 1.8 17.9 8.8 13.8 2 18.3 9.1 12.8 1.9 17.9 8.4 89 9 84 165 1.9 0 2.1 1.8 01/15/2006 17:10:00 13 1.8 17.2 9.1 13.3 1.9 17.6 9.1 12.7 1.9 17.6 8.4 91 9 84 165 2 0 2.1 1.8 01/15/2006 17:20:00 13.6 1.7 17.9 9.1 14.1 1.7 18.3 9.5 13.1 1.8 17.9 8.8 90 9 96 165 2 0 2.3 1.8 01/15/2006 17:30:00 13.8 2.3 18.7 8 14.2 2.3 18.7 8.4 13 2.2 18.3 7.6 94 8 96 165 2.1 0 2.3 1.8 01/15/2006 17:40:00 14 2.1 19.5 9.1 14.3 2.1 19.5 9.1 13.3 2 19.1 9.1 91 9 98 165 2 0 2.3 1.8 01/15/2006 17:50:00 14.4 1.8 18.7 9.5 14.6 1.9 18.7 9.9 13.7 1.7 18.3 8.4 92 8 101 165 2 0 2.3 1.8 01/15/2006 18:00:00 14.3 1.9 19.1 8.8 14.6 1.9 19.1 9.5 13.4 1.9 17.9 8.4 93 8 91 165 2 0 2.3 1.8 01/15/2006 18:10:00 14 2 18.3 8.8 14.2 2.1 18.7 9.5 13.2 1.9 17.6 8.4 92 9 111 165 2 0 2.3 1.8 01/15/2006 18:20:00 13.8 1.9 18.3 8 14.1 2 18.7 8 13.1 2 18.3 8.4 90 8 75 165 2.1 0 2.3 1.8 01/15/2006 18:30:00 14.5 1.7 18.7 9.5 14.8 1.8 19.1 9.5 13.8 1.7 18.7 8 88 7 88 165 2.1 0 2.3 1.8 01/15/2006 18:40:00 13.8 1.6 17.9 9.5 14.1 1.7 18.3 9.1 12.9 1.7 17.2 8.8 91 8 86 165 2.2 0 2.3 2.1 01/15/2006 18:50:00 13.1 2 17.6 8.4 13.4 2 17.6 8.4 12.5 1.9 17.6 8 90 9 98 165 2.1 0 2.3 2.1 01/15/2006 19:00:00 12.5 1.9 16.8 7.2 12.8 1.9 17.2 7.6 12.2 1.8 16.8 8.4 90 8 87 165 2.2 0 2.3 2.1 01/15/2006 19:10:00 13.7 1.8 18.7 9.1 14 1.9 19.1 9.5 13.1 1.8 18.3 8.4 90 8 81 165 2.1 0 2.3 1.8 01/15/2006 19:20:00 13.3 1.9 17.6 7.2 13.6 1.9 18.3 7.6 12.7 1.8 17.2 7.6 86 8 102 165 2.1 0 2.3 1.8 01/15/2006 19:30:00 13.6 1.7 17.2 9.5 13.9 1.7 17.6 9.5 13.1 1.8 17.6 9.1 86 8 95 165 2.1 0 2.3 2.1 01/15/2006 19:40:00 13.3 2 18.7 9.5 13.6 2.1 19.1 9.5 12.8 1.9 17.9 9.1 84 9 76 165 2.2 0 2.3 2.1 01/15/2006 19:50:00 14.1 2 19.1 9.5 14.4 2 19.5 9.5 13.6 2 18.7 9.1 86 7 87 165 2.1 0 2.3 1.8 01/15/2006 20:00:00 13 2 18.3 8 13.3 2.1 18.7 8 12.5 1.9 18.7 8.4 81 8 84 165 2.1 0 2.3 1.8 01/15/2006 20:10:00 14.2 2.3 20.6 9.5 14.6 2.4 20.2 9.1 13.7 2.2 18.7 8.8 85 8 97 165 2.1 0 2.3 1.8 01/15/2006 20:20:00 12.9 1.7 17.6 8.8 13.1 1.7 17.6 8.4 12.7 1.7 18.3 8.8 82 8 83 165 2.1 0 2.3 2.1 01/15/2006 20:30:00 12.5 1.6 16.4 7.2 12.8 1.7 16.8 7.2 12 1.8 16.4 7.2 82 9 87 165 2.1 0 2.3 2.1 01/15/2006 20:40:00 13.2 1.7 17.2 8.8 13.6 1.7 17.6 9.1 12.7 1.6 17.2 8.8 83 8 80 165 2.3 0 2.6 2.1 01/15/2006 20:50:00 13.1 2.4 18.7 8.4 13.4 2.4 19.1 8.4 12.5 2.2 18.3 7.2 84 8 87 165 2.3 0 2.6 2.3 01/15/2006 21:00:00 12.9 1.8 18.7 9.1 13.2 1.9 19.1 9.1 12.5 1.7 18.7 7.6 84 8 87 165 2.3 0 2.3 2.1 01/15/2006 21:10:00 13.1 1.5 17.2 9.1 13.4 1.6 17.2 8.4 12.5 1.6 16.4 8.8 79 8 66 165 2.3 0 2.6 2.1 01/15/2006 21:20:00 14.3 1.7 18.7 9.9 14.6 1.8 19.1 9.5 13.8 1.7 17.9 9.9 83 8 86 165 2.3 0 2.6 2.3 01/15/2006 21:30:00 13 2.2 17.2 7.2 13.2 2.2 17.9 7.6 12.3 2.1 16.8 7.2 86 8 84 165 2.4 0 2.6 2.3 01/15/2006 21:40:00 14.4 1.7 18.3 9.5 14.7 1.7 19.1 10.3 13.7 1.8 18.7 9.5 83 8 90 165 2.3 0 2.6 2.3 01/15/2006 21:50:00 13 1.7 18.7 9.5 13.3 1.8 19.1 9.5 12.7 1.8 17.9 9.1 83 8 84 165 2.3 0 2.6 2.3 01/15/2006 22:00:00 13 2 17.2 8.8 13.3 2 17.6 8.4 12.5 1.9 17.6 8.8 86 8 92 165 2.4 0 2.6 2.3 01/15/2006 22:10:00 14.2 1.8 18.7 9.5 14.5 1.8 19.1 9.9 13.5 1.8 17.9 8.8 86 8 89 165 2.4 0 2.6 2.3 01/15/2006 22:20:00 14.3 1.6 18.3 10.3 14.6 1.6 18.7 10.3 13.8 1.7 17.6 9.5 85 7 84 165 2.3 0 2.6 2.3 01/15/2006 22:30:00 12.5 1.8 17.6 8 12.8 1.8 17.9 8 12.1 1.6 16.1 8.4 80 9 96 165 2.4 0 2.6 2.3 01/15/2006 22:40:00 14.3 1.9 18.7 9.1 14.6 1.9 19.5 9.5 13.8 1.8 17.9 8.8 83 8 84 165 2.4 0.1 2.6 2.3 01/15/2006 22:50:00 13.6 1.8 18.7 9.1 13.9 1.9 18.3 9.1 13 1.8 17.6 8 83 8 73 165 2.4 0 2.6 2.3 01/15/2006 23:00:00 14.3 1.7 18.7 9.5 14.5 1.8 18.7 9.5 13.7 1.9 18.3 9.5 87 8 91 165 2.5 0 2.8 2.3 01/15/2006 23:10:00 12.8 2.1 17.6 8 13.1 2.2 17.9 8 12.6 2.1 17.9 7.6 82 9 83 165 2.6 0.1 2.8 2.3 01/15/2006 23:20:00 13.5 1.8 17.6 8.8 13.8 1.8 17.9 9.1 13 1.8 17.2 9.1 84 7 92 165 2.7 0 2.8 2.6 01/15/2006 23:30:00 14.2 1.5 18.3 10.7 14.5 1.6 18.3 10.7 13.7 1.6 18.3 9.5 84 8 83 165 2.6 0 2.8 2.6 01/15/2006 23:40:00 13.2 2 18.7 8.4 13.5 2.1 18.7 9.1 12.6 1.7 17.2 8.4 90 8 90 165 2.7 0 2.8 2.6 01/15/2006 23:50:00 12.8 2.1 17.6 7.6 13.1 2.2 17.9 8 12.1 2 17.2 7.6 90 10 89 165 2.7 0 2.8 2.6 01/16/2006 00:00:00 12.1 1.7 16.4 8 12.4 1.7 17.2 8.4 11.7 1.6 15.6 8.4 84 9 84 165 2.7 0 3 2.6 01/16/2006 00:10:00 13.4 1.7 17.2 8 13.7 1.7 17.6 7.6 12.7 1.6 17.2 8.8 87 9 89 165 2.8 0 2.8 2.6 01/16/2006 00:20:00 13.4 1.7 16.8 9.1 13.7 1.7 17.2 9.5 12.9 1.6 16.8 8.8 85 8 90 165 2.8 0 3 2.6 01/16/2006 00:30:00 13.1 1.5 17.2 9.5 13.3 1.6 17.6 9.9 12.3 1.7 16.4 8.4 87 8 86 165 2.9 0 3 2.8 01/16/2006 00:40:00 13.2 1.6 17.2 9.1 13.5 1.7 17.9 8.8 12.7 1.5 16.4 9.1 85 8 93 165 2.8 0 2.8 2.8 01/16/2006 00:50:00 13.2 1.5 17.2 9.5 13.4 1.5 17.6 9.5 12.2 1.5 16.4 8 90 8 94 165 2.9 0 3 2.8 01/16/2006 01:00:00 13.1 1.6 17.2 9.1 13.4 1.6 17.6 9.5 12.3 1.7 16.8 7.6 87 8 91 165 3 0 3 2.8 01/16/2006 01:10:00 13.4 1.4 16.8 9.5 13.8 1.5 17.2 9.9 12.8 1.5 17.2 8.4 88 7 85 165 2.9 0 3 2.8 01/16/2006 01:20:00 11.6 1.5 15.3 7.6 11.9 1.5 16.1 8.4 11.1 1.7 15.3 6.8 89 9 79 165 2.8 0 3 2.8 01/16/2006 01:30:00 11.2 2.2 16.1 6.5 11.5 2.3 16.8 6.5 10.8 2.1 16.8 6.5 83 10 90 165 2.9 0 3 2.8 01/16/2006 01:40:00 12.4 1.5 16.1 8.4 12.7 1.6 16.4 8 11.9 1.5 15.6 8 84 9 91 165 2.8 0 3 2.6 01/16/2006 01:50:00 11.2 1.4 14.9 7.6 11.5 1.5 14.9 8 10.7 1.4 15.3 7.6 81 7 82 165 2.7 0 2.8 2.6 01/16/2006 02:00:00 12.3 1.5 15.3 6.8 12.6 1.5 15.6 7.6 11.7 1.5 15.3 7.6 87 8 81 165 2.9 0 3 2.8 01/16/2006 02:10:00 11.8 1.6 15.6 8.8 12.1 1.7 16.1 8 11.3 1.6 14.9 7.2 90 8 73 165 3 0 3.3 2.8 01/16/2006 02:20:00 12.4 1.7 16.4 8 12.8 1.7 16.8 8.4 11.9 1.6 16.4 7.6 87 8 90 165 3 0 3.3 2.8 01/16/2006 02:30:00 12.2 1.7 16.4 8 12.5 1.7 16.1 8 11.4 1.7 15.6 6.8 92 8 103 165 3 0 3 2.8 01/16/2006 02:40:00 10.3 1.5 14.5 6.8 10.6 1.6 14.9 7.2 10.2 1.6 14.1 7.2 79 9 84 165 2.9 0 3.3 2.8 01/16/2006 02:50:00 12.1 1.5 15.6 8.4 12.3 1.5 15.6 8.4 11.3 1.5 14.9 7.6 88 9 89 165 3 0 3.3 2.8 01/16/2006 03:00:00 11 1.8 15.3 6.8 11.2 1.8 15.6 6.8 10.4 1.8 14.5 6.5 89 10 93 165 3.2 0 3.5 3 01/16/2006 03:10:00 11 1.6 14.9 7.6 11.2 1.7 14.9 8 10.7 1.6 14.9 7.2 83 8 81 165 3 0 3.3 2.8 01/16/2006 03:20:00 11.2 1.7 15.6 6.8 11.5 1.7 15.6 6.8 10.6 1.7 14.5 6.1 90 9 87 165 3.2 0 3.5 3 01/16/2006 03:30:00 11.4 1.6 14.9 7.2 11.7 1.6 15.3 7.6 11 1.5 14.5 7.2 90 9 103 165 3 0 3.3 2.8 01/16/2006 03:40:00 10.4 1.5 14.1 6.8 10.6 1.5 14.9 6.8 9.8 1.6 13.7 6.5 90 10 104 165 3.2 0 3.3 3 01/16/2006 03:50:00 10.5 1.5 14.9 6.8 10.8 1.6 15.3 6.8 10.3 1.4 13.7 6.8 85 10 86 165 3.1 0 3.3 3 01/16/2006 04:00:00 10.7 1.7 15.3 6.8 10.9 1.7 15.3 6.8 10.3 1.6 14.1 6.5 87 9 90 165 3.3 0 3.5 3.3 01/16/2006 04:10:00 9.5 1.7 13.7 6.1 9.7 1.7 13.7 6.5 9.2 1.5 13.3 5.7 85 10 84 165 3.1 0 3.5 2.8 01/16/2006 04:20:00 9.5 1.5 12.6 6.1 9.8 1.5 13 6.1 9.2 1.5 12.6 6.1 79 9 84 165 3 0 3 2.8 01/16/2006 04:30:00 9.6 1.3 13 6.5 9.8 1.4 13 6.5 9.3 1.3 13 5.7 78 8 78 165 3 0 3.3 2.8 01/16/2006 04:40:00 8.7 1.3 11.8 5.7 9 1.3 12.2 6.1 8.4 1.2 11.8 5.7 81 8 71 165 3 0 3 2.8 01/16/2006 04:50:00 8.2 1.7 12.2 5.3 8.4 1.7 12.6 4.9 7.9 1.5 12.2 4.9 87 10 89 165 3 0 3.3 3 01/16/2006 05:00:00 8.1 1.7 12.2 4.6 8.4 1.7 12.6 4.6 7.8 1.7 12.2 3.8 85 9 88 165 3 0 3.3 2.8 01/16/2006 05:10:00 8.5 1.5 11.8 4.9 8.6 1.5 12.2 4.9 8.2 1.4 10.7 4.2 74 9 70 165 3 0 3.3 2.8 01/16/2006 05:20:00 7.6 1.3 11.8 4.6 7.8 1.3 12.2 4.6 7.3 1 10.3 4.9 74 8 73 165 3 0 3.3 3 01/16/2006 05:30:00 6.9 1 9.5 4.6 7 1 9.5 4.6 6.6 1 9.1 4.2 72 10 91 165 3.1 0 3.3 3 01/16/2006 05:40:00 7.2 1.1 9.9 4.9 7.4 1.2 9.9 4.9 7 1.1 9.5 4.6 76 8 62 165 3.1 0 3.3 3 01/16/2006 05:50:00 6.7 1.2 9.9 4.2 6.9 1.2 9.9 4.2 6.5 1.2 9.9 3 78 8 83 165 3.2 0 3.3 3 01/16/2006 06:00:00 6.9 1 9.5 4.2 7.1 1.1 9.9 4.2 6.6 1 8.8 4.2 72 11 68 165 3.1 0 3.3 3 01/16/2006 06:10:00 7.2 1 10.3 4.6 7.4 1 10.3 5.3 7 1.1 9.9 4.6 76 9 75 165 3.1 0 3.3 3 01/16/2006 06:20:00 6 1 8.4 3.8 6.2 1 8.4 4.2 5.8 1 8 3.8 78 7 84 165 3.2 0 3.3 3 01/16/2006 06:30:00 7.6 1.5 10.7 4.6 7.7 1.6 11.1 4.2 7.2 1.5 10.7 3.4 64 10 67 165 3.1 0.1 3.5 3 01/16/2006 06:40:00 7.8 1.2 10.7 4.9 8 1.3 11.1 4.6 7.7 1.2 10.7 5.3 63 9 73 165 3.1 0.1 3.3 2.8 01/16/2006 06:50:00 7.7 1.3 11.1 4.9 7.8 1.3 11.5 5.3 7.3 1.2 10.3 4.2 68 8 70 165 2.9 0 3 2.8 01/16/2006 07:00:00 6.5 1.2 9.5 3.8 6.7 1.2 9.9 3.8 6.4 1.1 9.9 3.8 68 10 67 165 3 0 3 2.8 01/16/2006 07:10:00 6.6 1.3 9.9 3.4 6.8 1.3 10.3 3.8 6.4 1.2 9.1 3.8 61 12 53 165 3.1 0 3.3 3 01/16/2006 07:20:00 6.4 1.3 9.5 3 6.5 1.3 9.5 3 6.2 1.3 9.5 2.6 62 11 48 165 3.2 0 3.3 3.3 01/16/2006 07:30:00 6.4 1.2 9.5 3.4 6.6 1.2 9.9 3.4 6.4 1.2 9.9 3.8 65 10 65 165 3.3 0 3.5 3.3 01/16/2006 07:40:00 7.3 1.4 10.3 4.2 7.5 1.4 10.7 4.2 7 1.3 9.9 4.2 64 10 70 165 3.3 0 3.5 3.3 01/16/2006 07:50:00 7.1 1.1 9.9 4.2 7.2 1.1 10.3 4.6 6.8 1 9.5 4.6 63 11 55 165 3.4 0 3.5 3.3 01/16/2006 08:00:00 7 1.2 10.3 4.2 7.1 1.3 10.3 4.2 6.7 1.2 10.3 3.8 57 12 54 165 3.4 0 3.5 3.3 01/16/2006 08:10:00 8.3 1.4 11.5 4.9 8.4 1.5 11.8 4.6 7.7 1.4 11.5 3.4 54 9 62 165 3.3 0 3.5 3.3 01/16/2006 08:20:00 7.5 1.8 11.1 3.8 7.7 1.8 11.1 3.8 7.2 1.7 10.7 4.2 55 8 51 165 3.3 0 3.5 3.3 01/16/2006 08:30:00 6.3 1.4 9.1 3 6.4 1.5 9.5 3.4 6.2 1.5 9.1 2.6 55 11 60 165 3.3 0 3.5 3.3 01/16/2006 08:40:00 6.6 1.4 11.8 4.2 6.7 1.5 11.8 4.2 6.3 1.3 9.9 3.8 48 10 47 165 3.3 0 3.5 3.3 01/16/2006 08:50:00 6.4 1.4 9.9 3.4 6.5 1.4 10.7 3.4 6.2 1.3 9.5 3.8 48 11 51 165 3.3 0 3.5 3.3 01/16/2006 09:00:00 7.1 1.2 10.3 4.6 7.2 1.3 10.7 4.6 6.8 1.2 9.9 4.2 52 9 60 165 3.2 0 3.5 3.3 01/16/2006 09:10:00 6.8 1.1 9.9 4.2 6.9 1.1 10.3 4.2 6.5 1.1 9.1 3.8 51 10 50 165 3.2 0 3.5 3.3 01/16/2006 09:20:00 6.6 1.1 9.1 3.4 6.8 1.2 9.5 3.4 6.4 1.1 8.8 3 54 11 66 165 3.2 0 3.5 3.3 01/16/2006 09:30:00 7.7 1.3 10.3 4.6 7.8 1.3 10.7 4.6 7.4 1.3 10.7 4.2 46 11 53 165 3.2 0 3.5 3.3 01/16/2006 09:40:00 5.6 1 8.4 3.4 5.7 0.9 8.4 3.4 5.5 0.9 8.4 3 41 9 31 165 3.2 0 3.5 3.3 01/16/2006 09:50:00 6.3 1.1 8.4 3.4 6.4 1.1 8.8 3.4 5.9 1 8 3.8 52 9 41 165 3.2 0 3.5 3 01/16/2006 10:00:00 5.2 1.2 8.4 2.3 5.2 1.3 8.4 2.3 5 1.2 8 1.9 45 13 57 165 3.1 0 3.5 3 01/16/2006 10:10:00 5.5 1 7.6 3 5.6 1 8 3 5.1 1 7.2 2.3 52 10 63 165 3.2 0 3.5 3 01/16/2006 10:20:00 3.9 1.1 6.1 1.9 4 1.1 6.5 1.9 3.7 1.1 6.1 1.9 51 12 59 165 3.2 0 3.3 3 01/16/2006 10:30:00 3.4 0.8 5.7 1.1 3.6 0.8 5.7 1.5 3.4 0.8 5.3 1.5 43 8 43 165 3.3 0 3.5 3.3 01/16/2006 10:40:00 3.7 1.2 6.5 1.1 3.7 1.3 6.5 0.7 3.6 1.3 6.5 1.5 34 11 39 165 3.4 0 3.5 3.3 01/16/2006 10:50:00 4.5 0.8 6.5 2.3 4.4 0.8 6.5 2.3 4.4 0.8 6.5 2.6 24 7 28 165 3.6 0 3.8 3.5 01/16/2006 11:00:00 4.7 0.6 5.7 3.4 4.7 0.6 5.7 3 4.6 0.7 6.1 2.6 30 6 25 165 3.6 0 3.8 3.5 01/16/2006 11:10:00 2.9 0.7 4.9 1.5 2.9 0.7 4.6 0.7 2.7 0.7 4.2 1.1 35 12 22 165 3.6 0 3.8 3.5 01/16/2006 11:20:00 1.2 0.9 3.8 0.4 1.2 1 3.8 0.4 1.1 1 3.4 0.4 77 33 29 165 3.6 0 3.8 3.5 01/16/2006 11:30:00 1 0.4 1.9 0.4 1.1 0.4 2.3 0.4 1.1 0.4 1.9 0.4 159 7 145 165 3.6 0 3.8 3.5 01/16/2006 11:40:00 1.2 0.7 2.6 0.4 1.2 0.7 2.6 0.4 1.3 0.6 2.6 0.4 168 8 166 165 3.5 0 3.5 3.3 01/16/2006 11:50:00 0.4 0.2 1.1 0.4 0.5 0.3 1.5 0.4 0.7 0.4 1.9 0.4 196 18 213 165 3.3 0 3.5 3.3 01/16/2006 12:00:00 1.1 0.5 2.3 0.4 1.2 0.6 2.3 0.4 1.1 0.6 2.3 0.4 185 15 190 165 3.3 0 3.5 3.3 01/16/2006 12:10:00 0.5 0.3 1.9 0.4 0.8 0.5 1.9 0.4 0.8 0.6 2.6 0.4 219 28 235 165 3.5 0 3.5 3.3 01/16/2006 12:20:00 1 0.8 3 0.4 1.6 1 3.4 0.4 1.6 1 3.4 0.4 254 17 266 165 3.5 0 3.5 3.3 01/16/2006 12:30:00 3 0.5 4.2 1.5 3.3 0.4 4.2 2.3 3.2 0.3 4.2 2.3 273 4 281 165 3.5 0.1 3.8 3.3 01/16/2006 12:40:00 3.2 0.3 3.8 2.6 3.3 0.3 3.8 2.6 2.5 0.5 3.8 1.5 289 4 286 165 3.7 0 4 3.5 01/16/2006 12:50:00 2.7 0.3 3.4 1.9 2.7 0.3 3.4 1.9 2.1 0.3 2.6 1.5 300 5 290 165 4.1 0.2 4.5 3.8 01/16/2006 13:00:00 2 0.5 3 0.7 2.1 0.5 3 1.1 1.5 0.5 2.6 0.4 301 3 298 165 4.4 0 4.5 4.3 01/16/2006 13:10:00 0.7 0.5 2.3 0.4 0.7 0.5 2.3 0.4 0.6 0.5 2.6 0.4 198 72 158 165 4.5 0.3 5 4.3 01/16/2006 13:20:00 2 0.5 3 0.7 1.9 0.5 3.4 0.4 2 0.4 3.4 0.7 140 20 173 165 4.6 0.1 5.2 4.5 01/16/2006 13:30:00 1.1 0.6 2.6 0.4 1.1 0.6 2.3 0.4 1.1 0.6 2.6 0.4 121 12 122 165 4.1 0.1 4.5 4 01/16/2006 13:40:00 0.5 0.3 1.9 0.4 0.5 0.3 1.9 0.4 0.5 0.3 1.9 0.4 131 24 125 165 4 0 4.3 3.8 01/16/2006 13:50:00 2 0.6 3 0.4 2 0.6 3 0.7 1.9 0.6 3.4 0.4 123 9 132 165 3.7 0.2 4.3 3.5 01/16/2006 14:00:00 2.6 0.3 3.4 1.9 2.5 0.3 3.8 1.9 2.5 0.4 3.4 1.5 145 9 144 165 3.3 0 3.5 3.3 01/16/2006 14:10:00 3.5 0.7 4.9 1.9 3.6 0.7 4.9 1.5 3.6 0.7 4.6 1.9 139 6 135 165 3.4 0 3.5 3.3 01/16/2006 14:20:00 3.9 0.3 4.6 3 4 0.3 4.6 3.4 4 0.3 4.6 3.4 145 7 140 165 3.2 0 3.5 3.3 01/16/2006 14:30:00 4.1 0.3 4.9 3.4 4.1 0.2 4.9 3 4.3 0.2 5.3 3.4 154 4 157 165 3.2 0 3.3 3 01/16/2006 14:40:00 3.6 0.5 4.6 2.6 3.6 0.4 4.6 2.6 3.7 0.5 4.9 2.6 150 6 151 165 3 0 3.3 3 01/16/2006 14:50:00 2.9 0.3 3.8 2.3 3 0.3 3.8 2.3 3 0.3 3.8 2.3 149 5 150 165 3 0 3.3 3 01/16/2006 15:00:00 1.6 0.5 2.6 0.7 1.9 0.4 2.6 1.1 1.9 0.4 3 1.1 147 6 150 165 3 0 3.3 3 01/16/2006 15:10:00 0.9 0.3 1.5 0.4 1.1 0.4 1.5 0.4 1.1 0.4 1.9 0.4 151 3 146 165 3.1 0 3.3 3 01/16/2006 15:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 152 0 165 165 3.2 0 3.3 3 01/16/2006 15:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 161 19 165 165 3.3 0 3.5 3.3 01/16/2006 15:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 205 0 165 165 3.2 0 3.5 3.3 01/16/2006 15:50:00 0.4 0.2 1.1 0.4 0.5 0.2 1.5 0.4 0.5 0.3 1.5 0.4 205 2 205 165 3.2 0 3.3 3 01/16/2006 16:00:00 0.4 0.2 1.1 0.4 0.5 0.3 1.5 0.4 0.6 0.4 1.9 0.4 218 2 212 165 3.3 0 3.5 3 01/16/2006 16:10:00 0.4 0.1 1.1 0.4 0.5 0.3 1.5 0.4 0.4 0.2 1.5 0.4 278 20 263 165 2.9 0 3.5 2.6 01/16/2006 16:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 289 0 165 165 2.7 0 2.8 2.6 01/16/2006 16:30:00 0.4 0 0.4 0.4 0.4 0 0.7 0.4 0.4 0 0.7 0.4 186 72 165 165 2.6 0 2.8 2.6 01/16/2006 16:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 208 69 165 165 2.5 0 2.8 2.6 01/16/2006 16:50:00 0.4 0 0.7 0.4 0.4 0 0.7 0.4 0.4 0.1 1.1 0.4 3 94 135 165 2.4 0 2.6 2.3 01/16/2006 17:00:00 0.4 0.1 0.7 0.4 0.4 0.1 1.1 0.4 0.4 0.1 1.1 0.4 105 17 95 165 2.5 0 2.8 2.6 01/16/2006 17:10:00 0.4 0.1 1.1 0.4 0.5 0.2 1.1 0.4 0.6 0.4 1.5 0.4 97 8 95 165 2.4 0 2.8 2.3 01/16/2006 17:20:00 0.4 0 0.7 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 99 1 99 165 2.4 0 2.6 2.3 01/16/2006 17:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 99 0 165 165 2.4 0 2.6 2.3 01/16/2006 17:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 57 29 165 165 2.4 0 2.6 2.3 01/16/2006 17:50:00 0.4 0.1 1.1 0.4 0.4 0.1 1.1 0.4 0.4 0.2 1.9 0.4 31 14 354 165 2.2 0 2.3 2.1 01/16/2006 18:00:00 1.6 0.4 2.3 0.7 0.5 0.2 1.5 0.4 1.7 0.3 2.3 0.4 357 3 357 165 2 0 2.3 1.8 01/16/2006 18:10:00 1.4 0.3 1.9 0.7 1 0.4 1.9 0.4 1.2 0.4 1.9 0.4 11 5 10 165 2 0 2.3 1.8 01/16/2006 18:20:00 1.5 0.4 2.3 0.4 1 0.5 2.3 0.4 1.6 0.4 2.6 0.7 6 8 0 165 2.3 0 2.6 2.3 01/16/2006 18:30:00 1.1 0.7 2.3 0.4 0.7 0.4 1.9 0.4 1 0.8 2.6 0.4 359 12 359 165 2.3 0 2.6 2.3 01/16/2006 18:40:00 0.7 0.5 1.9 0.4 0.8 0.5 1.9 0.4 0.7 0.5 1.9 0.4 26 4 19 165 2.4 0.1 2.6 2.3 01/16/2006 18:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0.1 1.1 0.4 21 16 165 165 2.5 0 2.8 2.6 01/16/2006 19:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 341 0 165 165 2.4 0 2.6 2.6 01/16/2006 19:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 341 0 165 165 2.4 0 2.6 2.6 01/16/2006 19:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 341 0 165 165 2.4 0 2.6 2.3 01/16/2006 19:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 341 0 165 165 2.4 0 2.6 2.6 01/16/2006 19:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 341 0 165 165 2.4 0 2.6 2.3 01/16/2006 19:50:00 1.3 0.9 3.4 0.4 1.3 0.9 3.4 0.4 1.4 0.9 3.4 0.4 331 13 329 165 2.3 0 2.6 2.3 01/16/2006 20:00:00 2.2 1 3.8 0.4 2.2 1 3.8 0.4 2.3 1.1 4.2 0.4 326 12 326 165 2.3 0 2.3 2.3 01/16/2006 20:10:00 1.2 0.4 1.9 0.4 1.3 0.5 2.3 0.4 1.1 0.5 2.3 0.4 311 15 306 165 2.3 0 2.3 2.3 01/16/2006 20:20:00 1.4 0.7 3 0.4 1.5 0.7 3.4 0.4 1.4 0.6 2.6 0.4 296 8 295 165 2.3 0 2.3 2.3 01/16/2006 20:30:00 3.1 0.2 3.8 2.6 3.2 0.2 3.8 2.6 2.2 0.4 3.4 1.1 296 6 286 165 2.2 0 2.3 2.3 01/16/2006 20:40:00 2.6 0.5 3.4 1.5 2.7 0.5 3.4 1.5 2.2 0.5 3 0.7 305 6 305 165 2.1 0 2.3 2.1 01/16/2006 20:50:00 1.5 0.4 2.3 0.7 1.7 0.3 2.6 1.1 1.2 0.4 2.3 0.4 301 5 291 165 2.2 0 2.3 2.1 01/16/2006 21:00:00 0.7 0.3 1.5 0.4 1 0.3 1.5 0.4 0.7 0.3 1.5 0.4 307 3 303 165 2.1 0 2.3 2.1 01/16/2006 21:10:00 0.8 0.5 1.9 0.4 1.2 0.4 1.9 0.4 0.9 0.5 1.9 0.4 310 6 307 165 2.1 0 2.3 1.8 01/16/2006 21:20:00 1.2 0.4 2.6 0.4 1.4 0.4 2.6 0.4 1.1 0.5 2.3 0.4 306 13 315 165 2 0 2.3 1.8 01/16/2006 21:30:00 1.7 0.4 2.6 0.7 1.9 0.4 2.6 1.1 1.7 0.4 2.6 0.7 329 12 321 165 2 0 2.3 1.8 01/16/2006 21:40:00 1.5 0.5 3 0.4 1.8 0.5 3 0.7 1.4 0.5 2.6 0.4 316 11 328 165 2.1 0 2.3 1.8 01/16/2006 21:50:00 1.1 0.5 2.3 0.4 1.3 0.4 2.3 0.4 1.2 0.4 2.3 0.4 318 12 314 165 2.2 0 2.3 2.1 01/16/2006 22:00:00 2.6 0.5 3.4 1.1 2.7 0.5 3.8 1.5 2.3 0.5 3.8 0.7 310 8 310 165 2.1 0 2.3 1.8 01/16/2006 22:10:00 3 0.3 3.8 2.3 3.1 0.3 3.8 2.3 2.9 0.3 3.8 2.3 318 5 315 165 2 0 2.3 1.8 01/16/2006 22:20:00 3 0.4 3.8 1.9 3 0.4 3.8 2.3 2.9 0.3 3.8 2.3 329 6 330 165 1.9 0 2.1 1.8 01/16/2006 22:30:00 2.5 0.3 3.4 1.9 2.6 0.3 3.4 1.9 2.5 0.3 3 1.5 324 7 323 165 1.9 0 2.1 1.8 01/16/2006 22:40:00 2.7 0.5 4.2 1.5 2.8 0.4 3.8 1.5 2.5 0.5 3.8 1.5 321 12 341 165 2 0 2.3 1.8 01/16/2006 22:50:00 2.8 0.4 4.2 1.9 2.9 0.4 4.6 1.9 2.6 0.4 3.8 1.9 321 11 325 165 1.9 0 2.3 1.8 01/16/2006 23:00:00 3.2 0.5 4.2 0.4 3.3 0.5 4.2 1.1 3.1 0.5 4.2 1.9 320 8 328 165 1.9 0 1.8 1.8 01/16/2006 23:10:00 3.4 0.5 4.6 1.9 3.4 0.5 4.6 2.3 3 0.6 4.6 1.9 312 8 321 165 1.9 0 2.1 1.8 01/16/2006 23:20:00 3.2 0.6 5.3 1.9 3.3 0.6 5.3 2.3 3.2 0.5 4.6 1.9 316 7 320 165 1.9 0 1.8 1.8 01/16/2006 23:30:00 4.5 0.6 6.1 3 4.5 0.6 6.1 3 4.2 0.6 6.1 2.6 321 11 340 165 1.9 0 1.8 1.8 01/16/2006 23:40:00 3.8 0.5 5.7 2.3 3.8 0.5 5.3 2.3 3.5 0.7 5.7 1.9 319 11 350 165 1.9 0 1.8 1.8 01/16/2006 23:50:00 3.6 0.9 5.3 1.9 3.6 0.8 5.3 1.9 3.4 0.9 6.1 1.5 315 10 308 165 1.9 0 1.8 1.8 01/17/2006 00:00:00 3.5 1.3 7.6 1.9 3.6 1.2 7.6 1.9 3.6 1.2 7.6 1.9 327 9 332 165 1.8 0 1.8 1.8 01/17/2006 00:10:00 5.8 1 8.4 3.8 5.7 1 8 3.8 5.7 1 8 3.8 329 9 342 165 1.8 0 1.8 1.6 01/17/2006 00:20:00 6.5 0.7 8.4 4.6 6.4 0.8 8.4 3.8 6.4 0.8 8 4.6 337 10 332 165 1.7 0 1.8 1.6 01/17/2006 00:30:00 4.6 0.7 6.8 2.6 4.4 0.8 6.8 2.3 4.4 1 6.8 2.6 327 16 349 165 1.5 0 1.6 1.4 01/17/2006 00:40:00 5.5 1.3 8 2.6 5.4 1.4 8 2.6 5.3 1.3 7.6 2.6 315 1 315 165 1.6 0 1.6 1.4 01/17/2006 00:50:00 7.3 0.6 8.8 5.7 7.5 0.8 9.1 5.7 7.3 0.6 8.8 5.3 318 0 318 165 1.6 0 1.6 1.4 01/17/2006 01:00:00 7.1 0.8 9.1 5.3 7.3 0.9 9.5 5.7 7 1 9.5 4.6 318 0 318 165 1.5 0.1 1.6 1.4 01/17/2006 01:10:00 6.7 0.7 8.4 4.9 6.6 1.2 9.1 1.9 6.4 1 8 3.4 318 0 319 165 1.2 0 1.4 0.9 01/17/2006 01:20:00 7.3 0.6 9.1 5.7 7.5 0.9 9.5 4.6 7.1 0.7 8.8 5.3 318 0 319 165 0.9 0 1.1 0.9 01/17/2006 01:30:00 7.4 0.7 9.5 5.7 7.5 1 9.5 3.8 7 0.9 9.1 4.6 318 0 319 165 0.9 0 1.4 0.9 01/17/2006 01:40:00 7.7 0.7 9.5 6.1 7.8 0.9 9.9 5.3 7.1 0.9 8.8 4.9 318 0 319 165 1 0 1.1 0.9 01/17/2006 01:50:00 5.4 1.1 8 3.4 5.3 1.1 7.6 3.4 4.2 2.2 7.6 0.4 318 0 319 165 1 0 1.4 0.9 01/17/2006 02:00:00 4.7 0.5 6.1 3.8 4.6 0.5 5.7 3.4 0.4 0 0.4 0.4 318 0 319 165 0.9 0 1.4 0.9 01/17/2006 02:10:00 5.5 0.7 7.2 3.8 5.4 0.7 7.2 3.4 0.4 0 0.4 0.4 319 0 319 165 0.9 0 1.1 0.9 01/17/2006 02:20:00 8 1 9.9 4.6 8 1 9.9 4.9 0.4 0 0.4 0.4 318 0 319 165 1 0 1.1 0.9 01/17/2006 02:30:00 8.2 0.8 10.3 5.3 8.1 0.9 9.9 5.3 0.4 0 0.4 0.4 319 0 319 165 1.1 0 1.4 0.9 01/17/2006 02:40:00 8.6 0.7 10.3 6.5 8.6 0.7 10.3 6.5 0.4 0 0.4 0.4 319 0 319 165 1.1 0 1.4 0.9 01/17/2006 02:50:00 8.4 1 11.1 4.6 8.3 1 10.7 4.9 0.4 0 0.4 0.4 318 0 319 165 1.1 0 1.4 0.9 01/17/2006 03:00:00 8 0.8 10.3 6.1 8 0.8 9.9 6.1 0.4 0 0.4 0.4 318 0 319 165 1.3 0 1.4 1.1 01/17/2006 03:10:00 8 1 10.3 5.3 7.9 1 10.3 5.3 0.4 0 0.4 0.4 319 0 319 165 1.3 0 1.4 1.4 01/17/2006 03:20:00 8.6 1.1 11.1 6.1 8.5 1 11.1 6.1 0.4 0 0.4 0.4 318 0 319 165 1.2 0 1.4 1.1 01/17/2006 03:30:00 7.3 1.2 9.9 3.8 7.2 1.2 9.9 3.8 0.4 0 0.4 0.4 318 0 319 165 1.1 0 1.4 0.9 01/17/2006 03:40:00 8.1 0.9 10.3 5.3 8 0.9 9.9 5.3 0.4 0 0.4 0.4 318 0 319 165 1.1 0 1.4 1.1 01/17/2006 03:50:00 8.1 1 10.7 5.7 8.1 1 10.7 5.7 0.4 0 0.4 0.4 318 0 319 165 1.1 0 1.4 1.1 01/17/2006 04:00:00 9.2 0.9 11.8 6.5 9.1 0.9 11.5 6.5 0.4 0 0.4 0.4 318 0 319 165 1.1 0 1.4 1.1 01/17/2006 04:10:00 9.1 1.1 11.1 5.3 9 1 11.5 5.3 0.4 0 0.4 0.4 318 0 319 165 1.1 0 1.4 0.9 01/17/2006 04:20:00 8.7 1.3 11.5 4.6 8.6 1.3 11.1 4.2 0.4 0 0.4 0.4 318 0 319 165 1.2 0 1.4 1.1 01/17/2006 04:30:00 8.5 0.8 11.1 6.5 8.5 0.8 11.1 6.5 0.4 0 0.4 0.4 318 0 319 165 1.2 0 1.4 1.1 01/17/2006 04:40:00 8.6 0.9 11.5 6.8 8.5 0.9 11.1 6.8 0.4 0 0.4 0.4 318 0 319 165 1.2 0 1.4 1.4 01/17/2006 04:50:00 9.3 1.1 11.5 6.5 9.3 1.1 11.1 6.5 0.4 0 0.4 0.4 318 0 319 165 1.2 0 1.4 1.1 01/17/2006 05:00:00 7.7 0.8 9.9 6.1 7.8 0.8 9.9 6.1 0.4 0 0.4 0.4 318 0 319 165 1.2 0 1.4 1.1 01/17/2006 05:10:00 7.2 0.8 9.5 5.3 7.2 0.8 9.9 5.3 0.4 0 0.4 0.4 318 0 319 165 1.2 0 1.4 1.1 01/17/2006 05:20:00 7.8 0.7 9.5 5.7 7.7 0.7 9.1 5.7 0.4 0 0.4 0.4 318 0 319 165 1.2 0 1.4 1.1 01/17/2006 05:30:00 7.1 0.8 8.4 5.3 7.1 0.8 8.8 5.3 0.4 0 0.4 0.4 318 0 319 165 1.1 0 1.4 1.1 01/17/2006 05:40:00 7.5 0.9 10.7 4.9 7.4 0.9 9.9 4.9 0.4 0 0.4 0.4 318 0 319 165 1 0 1.4 0.9 01/17/2006 05:50:00 7.8 1.1 10.3 5.3 7.7 1.1 10.3 4.9 0.4 0 0.4 0.4 318 0 319 165 0.9 0 1.1 0.9 01/17/2006 06:00:00 7.7 0.7 9.9 5.7 7.7 0.7 9.9 6.1 0.4 0 0.4 0.4 318 0 319 165 0.9 0 1.1 0.9 01/17/2006 06:10:00 6.9 0.7 8.4 4.9 6.9 0.7 8.4 5.3 0.4 0 0.4 0.4 318 0 319 165 0.8 0 0.9 0.9 01/17/2006 06:20:00 7.4 0.8 9.1 5.3 7.4 0.8 9.1 5.3 0.4 0 0.4 0.4 318 0 319 165 0.8 0 0.9 0.9 01/17/2006 06:30:00 7.8 0.7 9.1 5.7 7.8 0.6 9.1 6.1 0.4 0 0.4 0.4 318 0 319 165 0.8 0 0.9 0.9 01/17/2006 06:40:00 8 0.6 9.1 5.7 7.9 0.6 9.1 5.7 0.4 0 0.4 0.4 319 0 319 165 0.8 0 1.1 0.9 01/17/2006 06:50:00 7.9 0.5 9.1 6.1 7.9 0.6 9.1 6.1 0.4 0 0.4 0.4 319 0 319 165 1 0 1.4 0.9 01/17/2006 07:00:00 7.4 0.4 8.4 6.1 7.4 0.4 8.4 6.1 0.4 0 0.4 0.4 319 0 319 165 0.9 0 1.1 0.9 01/17/2006 07:10:00 6.2 0.7 8 4.9 6.3 0.7 8 4.9 0.4 0 0.4 0.4 319 0 319 165 1.1 0 1.4 0.9 01/17/2006 07:20:00 6.1 0.5 7.6 4.9 6.1 0.5 7.6 4.9 0.4 0 0.4 0.4 319 0 319 165 1.1 0 1.4 0.9 01/17/2006 07:30:00 7.2 0.5 8.4 5.7 7.2 0.5 8.4 6.1 0.4 0 0.4 0.4 319 0 319 165 1.1 0 1.4 1.1 01/17/2006 07:40:00 7.4 0.5 8.8 6.1 7.3 0.5 8.8 6.1 0.4 0 0.4 0.4 319 0 319 165 1.1 0 1.4 0.9 01/17/2006 07:50:00 7.3 0.5 8.4 5.7 7.2 0.4 8 5.7 0.4 0 0.4 0.4 319 0 319 165 0.9 0 1.1 0.9 01/17/2006 08:00:00 6.7 0.7 8.4 4.6 6.7 0.7 8.4 4.6 0.4 0 0.4 0.4 319 0 319 165 0.9 0 1.1 0.9 01/17/2006 08:10:00 6.3 0.6 7.6 4.6 6.3 0.6 7.6 4.6 0.4 0 0.4 0.4 319 0 319 165 0.8 0 0.9 0.9 01/17/2006 08:20:00 6.8 0.7 8.4 4.9 6.8 0.6 8.4 5.3 0.4 0 0.4 0.4 319 0 319 165 1 0 1.4 0.9 01/17/2006 08:30:00 7.1 0.5 8.4 5.7 7 0.5 8 5.7 0.4 0 0.4 0.4 319 0 319 165 1.1 0 1.4 0.9 01/17/2006 08:40:00 6.7 0.5 8 5.3 6.7 0.5 8 5.3 0.4 0 0.4 0.4 319 0 319 165 1 0 1.4 0.9 01/17/2006 08:50:00 7.1 0.6 8.4 5.7 7.1 0.6 8.4 5.7 0.4 0 0.4 0.4 319 0 319 165 0.9 0 1.1 0.9 01/17/2006 09:00:00 7.4 0.6 9.9 5.7 7.4 0.6 9.9 5.7 0.4 0 0.4 0.4 319 0 319 165 0.9 0 1.1 0.9 01/17/2006 09:10:00 7.9 0.6 9.5 6.5 7.8 0.6 9.1 6.5 0.4 0 0.4 0.4 319 0 319 165 0.9 0 1.1 0.9 01/17/2006 09:20:00 8.6 0.6 9.9 6.8 8.5 0.6 9.5 6.8 0.4 0 0.4 0.4 319 0 319 165 0.9 0 1.1 0.9 01/17/2006 09:30:00 7.4 0.6 8.4 5.3 7.4 0.6 8.8 5.3 0.4 0 0.4 0.4 319 0 319 165 0.9 0 1.1 0.9 01/17/2006 09:40:00 7.5 0.6 9.1 5.7 7.5 0.6 9.1 6.1 0.4 0 0.4 0.4 319 0 319 165 1.1 0 1.4 0.9 01/17/2006 09:50:00 6.6 0.6 8 5.3 6.7 0.6 8 4.9 4.9 1.5 7.2 0.4 319 0 319 165 1.2 0 1.4 0.9 01/17/2006 10:00:00 6.3 0.6 7.6 4.9 6.3 0.6 8 4.2 5.6 0.6 6.8 4.2 319 0 319 165 0.9 0 1.4 0.9 01/17/2006 10:10:00 5.7 0.8 7.2 3 5.8 0.8 7.6 3.4 4.8 0.7 6.5 2.6 318 0 319 165 1.5 0 1.8 1.1 01/17/2006 10:20:00 6.2 0.7 8 4.6 6.3 0.7 8 4.6 4.7 0.6 6.5 3 318 0 319 165 1.7 0 1.8 1.6 01/17/2006 10:30:00 5.8 0.6 8 4.2 5.8 0.6 7.6 4.2 4.6 0.8 7.2 3 318 0 319 165 1.7 0 1.8 1.6 01/17/2006 10:40:00 5 0.8 6.8 2.6 5.1 0.8 6.5 3 3.8 0.7 5.7 2.3 318 0 319 165 2 0 2.3 1.6 01/17/2006 10:50:00 4.4 0.5 5.7 3 4.5 0.5 5.7 3 3.7 0.6 5.3 2.3 318 0 319 165 2.3 0 2.6 2.3 01/17/2006 11:00:00 4.1 0.8 6.1 1.9 4.2 0.8 5.7 2.3 3.2 0.7 4.9 1.5 318 0 319 165 2.4 0.1 2.8 2.3 01/17/2006 11:10:00 2.7 1.2 5.3 0.4 2.7 1.1 5.3 0.4 1.9 1 4.2 0.4 318 0 319 165 3 0.3 3.5 2.6 01/17/2006 11:20:00 1.7 0.8 4.2 0.4 1.9 0.9 4.6 0.4 1.6 0.9 4.2 0.4 318 0 318 165 3.6 0.1 3.8 3.5 01/17/2006 11:30:00 2.4 0.9 4.6 0.4 2.5 0.8 4.2 0.4 2.1 0.7 4.2 0.4 310 7 317 165 3.5 0 3.8 3.5 01/17/2006 11:40:00 2.7 0.7 4.2 1.1 2.8 0.7 4.6 1.1 2.3 0.7 4.2 0.7 287 8 292 165 3.3 0.1 3.5 3 01/17/2006 11:50:00 2.3 0.9 4.2 0.4 2.7 0.8 4.2 0.7 2.3 0.8 4.2 0.4 284 1 281 165 3.5 0.2 3.8 3 01/17/2006 12:00:00 3.4 0.5 4.6 1.9 3.6 0.5 4.6 2.3 3 0.6 4.9 1.5 295 9 285 165 3 0 3.3 2.8 01/17/2006 12:10:00 3.5 1 6.8 1.1 3.7 1 6.8 1.9 3.1 0.8 5.3 1.9 299 4 302 165 3.2 0.2 3.5 2.8 01/17/2006 12:20:00 2.8 0.7 4.6 1.1 3.2 0.6 4.9 1.9 2.7 0.6 4.9 1.5 299 2 306 165 3.5 0 3.8 3.3 01/17/2006 12:30:00 5 0.9 7.2 2.3 5.1 0.8 7.6 3 4.6 1 8 2.6 310 9 317 165 3.3 0.2 3.8 3 01/17/2006 12:40:00 4.8 1 7.6 2.3 4.9 0.9 7.6 3 4.3 1 7.2 1.9 310 9 312 165 3 0 3.3 3 01/17/2006 12:50:00 4.7 0.8 7.2 2.3 4.8 0.8 6.8 3 4.1 0.8 6.5 2.6 309 8 317 165 3.2 0 3.5 3 01/17/2006 13:00:00 5.2 0.9 7.2 3.4 5.3 0.9 7.6 3.4 4.4 0.9 6.8 2.6 301 8 311 165 3.1 0.1 3.5 2.8 01/17/2006 13:10:00 7.1 0.8 9.1 5.3 7.1 0.8 9.1 5.3 5.6 0.9 8.8 3.4 296 5 297 165 2.5 0.1 3 2.3 01/17/2006 13:20:00 6.6 0.9 8.4 4.2 6.5 0.9 8 4.2 5 0.7 6.5 3.4 300 5 296 165 2.5 0 2.8 2.3 01/17/2006 13:30:00 3.6 0.9 6.1 1.5 3.8 0.8 6.1 1.9 3.2 0.7 5.3 1.5 308 11 314 165 3.3 0.3 3.8 2.8 01/17/2006 13:40:00 3.9 0.8 5.7 2.3 4 0.7 5.7 2.6 3.6 0.9 5.7 1.9 308 11 312 165 3.4 0.1 3.8 3.3 01/17/2006 13:50:00 3.4 0.7 5.3 1.1 3.8 0.7 6.5 1.9 3 0.6 4.6 1.5 288 12 291 165 3.3 0 3.5 3.3 01/17/2006 14:00:00 2.1 0.8 3.8 0.7 2.6 0.6 4.2 1.5 2.2 0.5 3.4 0.7 281 17 291 165 3.3 0 3.5 3.3 01/17/2006 14:10:00 2.3 0.4 3.4 0.7 2.6 0.4 3.4 1.5 2.7 0.3 3.4 1.5 237 8 241 165 3.6 0 3.8 3.5 01/17/2006 14:20:00 3 0.6 4.2 1.9 3.9 0.6 5.7 1.9 3.8 0.6 4.9 2.3 266 10 267 165 3.8 0 4 3.5 01/17/2006 14:30:00 3.2 0.7 4.6 1.1 3.7 0.4 4.9 2.6 3.5 0.5 4.6 2.3 276 8 285 165 3.3 0.1 3.8 3 01/17/2006 14:40:00 3.3 0.7 4.6 1.5 3.9 0.4 4.9 2.6 3.7 0.4 4.6 2.6 274 7 283 165 3.6 0.1 4 3.3 01/17/2006 14:50:00 3.5 0.5 4.9 1.5 3.6 0.5 5.3 2.3 2.9 0.5 4.2 1.1 294 11 304 165 3.4 0.1 3.8 3.3 01/17/2006 15:00:00 4.4 0.6 5.7 3 4.5 0.6 5.7 3.4 3.4 0.5 4.6 2.3 301 5 299 165 3.2 0.1 3.8 2.8 01/17/2006 15:10:00 5.3 0.4 6.1 4.2 5.3 0.4 6.5 4.2 4.1 0.5 5.3 2.6 306 4 305 165 2.7 0.1 3 2.6 01/17/2006 15:20:00 5.6 0.4 6.5 4.2 5.6 0.4 6.5 4.2 4.9 0.7 6.5 3 310 3 303 165 2.6 0 2.8 2.6 01/17/2006 15:30:00 7.1 0.7 8.4 4.9 7 0.7 8.4 4.9 5.5 0.7 7.2 4.2 307 6 304 165 2.3 0.2 2.8 1.8 01/17/2006 15:40:00 7.7 0.7 9.1 5.3 7.6 0.7 9.1 5.3 6.4 0.8 8.4 4.6 307 4 307 165 1.9 0 2.1 1.6 01/17/2006 15:50:00 7.7 0.6 8.8 5.7 7.5 0.6 8.8 5.3 5.9 0.9 8 3.8 304 6 301 165 1.7 0 1.8 1.6 01/17/2006 16:00:00 7.8 0.7 9.1 5.7 7.7 0.7 9.1 5.7 5.9 0.8 8 4.2 303 4 302 165 1.7 0 1.8 1.6 01/17/2006 16:10:00 6.4 1.3 8.4 2.6 6.4 1.3 8.4 3 5 1 7.2 2.3 297 6 304 165 1.7 0.1 1.8 1.6 01/17/2006 16:20:00 4.2 0.6 6.1 2.6 4.3 0.5 6.1 2.6 3.6 0.6 6.1 2.3 294 8 294 165 1.9 0 1.8 1.8 01/17/2006 16:30:00 5.7 0.9 8 3.8 5.7 0.9 8 3.8 4.7 0.8 6.8 2.6 293 6 301 165 1.7 0 1.8 1.6 01/17/2006 16:40:00 6.7 0.8 8 4.6 6.6 0.8 8 4.9 5 0.7 6.8 3 298 5 305 165 1.4 0.1 1.8 1.4 01/17/2006 16:50:00 6.4 0.6 7.6 4.9 6.5 0.6 8 4.9 4.7 0.6 6.5 3.4 299 5 297 165 1.3 0 1.4 1.4 01/17/2006 17:00:00 6.2 0.5 7.2 4.9 6.3 0.5 7.2 4.9 4.8 0.7 6.8 3 297 6 302 165 1.4 0 1.6 1.4 01/17/2006 17:10:00 6.4 0.5 8 4.9 6.4 0.6 8 4.6 4.9 0.6 6.8 3.4 298 5 297 165 1.4 0 1.6 1.4 01/17/2006 17:20:00 6.2 0.7 8 3.8 6.3 0.7 8 4.2 4.8 0.7 6.5 3.4 296 5 296 165 1.4 0 1.6 1.4 01/17/2006 17:30:00 7.4 0.7 8.8 4.9 7.4 0.7 8.8 4.9 5.2 0.6 7.2 3.4 299 4 298 165 1.5 0 1.6 1.4 01/17/2006 17:40:00 8.3 0.6 9.5 6.1 8.2 0.6 9.5 6.1 5.9 0.7 8 4.2 299 4 300 165 1.6 0 1.8 1.6 01/17/2006 17:50:00 8.7 0.8 10.3 6.1 8.6 0.8 10.3 6.5 6 0.7 8.4 4.6 300 4 302 165 1.5 0 1.8 1.4 01/17/2006 18:00:00 9.2 0.6 10.7 7.2 9.1 0.7 10.3 7.2 6.5 0.7 8.4 4.6 303 4 302 165 1.7 0 1.8 1.6 01/17/2006 18:10:00 9.1 0.5 10.3 7.6 9 0.5 10.3 7.6 6.3 0.6 8.4 4.6 302 3 304 165 1.6 0 1.8 1.4 01/17/2006 18:20:00 8.8 0.5 9.9 7.2 8.8 0.5 9.9 6.8 5.9 0.5 8 4.6 301 3 302 165 1.7 0 1.8 1.6 01/17/2006 18:30:00 8.6 0.5 9.9 6.8 8.6 0.6 9.5 6.5 5.9 0.6 7.6 4.2 301 4 301 165 1.8 0 1.8 1.6 01/17/2006 18:40:00 7.4 0.8 10.3 5.3 7.3 0.8 9.9 4.9 5.4 1 9.5 3.4 301 5 310 165 2 0 2.3 1.8 01/17/2006 18:50:00 7.2 1 9.9 4.9 7.1 1 9.9 4.6 5.7 1.2 9.1 3.4 303 8 295 165 2.3 0.1 2.6 1.8 01/17/2006 19:00:00 6.3 0.8 8 4.2 6.2 0.7 8 4.2 4.6 0.8 6.8 3 304 6 310 165 1.9 0 2.3 1.8 01/17/2006 19:10:00 5.4 0.6 6.8 3.8 5.3 0.6 6.8 3.8 4.7 0.8 6.5 3 309 7 312 165 2 0 2.3 1.8 01/17/2006 19:20:00 3.5 1 6.1 0.4 3.4 1 6.1 0.4 3.2 0.8 4.9 1.1 317 13 311 165 1.9 0 2.1 1.6 01/17/2006 19:30:00 3.7 0.7 5.7 1.9 3.6 0.7 5.7 1.9 3.1 0.8 5.7 0.4 303 12 299 165 1.8 0 2.1 1.6 01/17/2006 19:40:00 5.1 0.8 7.2 3 5.1 0.8 6.8 3 4.2 0.9 6.5 2.3 294 8 297 165 1.7 0 1.8 1.4 01/17/2006 19:50:00 3.4 0.6 4.9 1.9 3.4 0.5 4.9 2.3 3 0.7 4.6 1.5 305 12 310 165 1.7 0 1.8 1.6 01/17/2006 20:00:00 4 0.7 5.3 2.6 4 0.7 5.3 2.6 3.6 0.9 5.3 1.1 291 7 282 165 1.6 0.1 1.8 1.4 01/17/2006 20:10:00 3.5 0.7 4.9 1.5 3.8 0.6 4.9 2.3 3.3 0.6 4.6 1.9 278 10 292 165 1.4 0.1 1.6 1.4 01/17/2006 20:20:00 3.4 0.5 4.6 1.5 3.4 0.5 4.6 1.5 3 0.6 4.2 1.1 302 17 306 165 1.2 0 1.6 0.9 01/17/2006 20:30:00 4.3 0.5 6.1 3 4.3 0.5 6.1 3 4.1 0.5 5.7 2.6 315 7 310 165 0.9 0 1.1 0.9 01/17/2006 20:40:00 3.7 0.7 5.3 1.9 3.6 0.8 5.3 1.1 3.5 0.5 4.6 2.3 321 14 304 165 0.9 0 1.1 0.9 01/17/2006 20:50:00 3.6 0.5 4.6 2.3 3.5 0.5 4.6 1.5 3.4 0.5 5.3 1.9 321 13 354 165 1.1 0 1.4 0.9 01/17/2006 21:00:00 2.8 0.5 4.6 1.5 2.7 0.6 4.6 1.1 2.7 0.5 4.2 1.5 321 9 314 165 1.2 0 1.4 1.1 01/17/2006 21:10:00 2.8 0.6 4.2 1.1 2.6 0.6 3.8 0.7 2.6 0.7 3.8 0.4 325 9 326 165 1.2 0 1.4 1.1 01/17/2006 21:20:00 1.2 0.5 3 0.4 1 0.5 2.6 0.4 1.1 0.5 2.6 0.4 337 15 349 165 1.2 0 1.4 1.1 01/17/2006 21:30:00 2.3 0.4 3.4 1.5 2.1 0.5 3.4 0.4 2.4 0.4 3 1.1 338 12 353 165 1.3 0.1 1.4 1.1 01/17/2006 21:40:00 3 0.5 4.9 1.9 2.4 0.8 4.9 0.7 3.1 0.5 4.9 2.3 351 11 336 165 1.1 0.1 1.4 0.9 01/17/2006 21:50:00 2.6 0.4 3.8 1.5 2.2 0.5 3.8 0.7 2.6 0.4 3.8 1.5 346 9 339 165 1.1 0 1.4 0.9 01/17/2006 22:00:00 1.2 0.6 2.6 0.4 0.8 0.4 2.3 0.4 1.4 0.6 3 0.4 23 22 3 165 0.9 0 1.1 0.9 01/17/2006 22:10:00 0.6 0.4 1.5 0.4 0.4 0.2 1.1 0.4 0.6 0.5 2.3 0.4 112 86 182 165 1.3 0.1 1.4 0.9 01/17/2006 22:20:00 2.1 0.5 3 0.7 1.6 0.8 3 0.4 2 0.4 3 1.1 329 29 334 165 1.1 0.1 1.4 0.9 01/17/2006 22:30:00 1.4 0.5 2.6 0.4 1.1 0.5 2.6 0.4 1.3 0.5 2.6 0.4 327 22 294 165 1 0 1.4 0.9 01/17/2006 22:40:00 1.7 0.5 3 0.4 1.4 0.5 3 0.4 1.6 0.5 2.6 0.4 326 13 343 165 1.3 0 1.4 1.1 01/17/2006 22:50:00 1.7 0.4 2.6 0.7 1.6 0.5 2.6 0.4 1.6 0.5 2.6 0.4 325 14 323 165 1.2 0 1.4 0.9 01/17/2006 23:00:00 0.7 0.4 1.5 0.4 0.5 0.3 1.5 0.4 0.5 0.3 1.5 0.4 320 15 349 165 1.1 0.2 1.4 0.9 01/17/2006 23:10:00 1.7 0.7 3 0.4 1.5 0.7 2.6 0.4 1.5 0.8 3 0.4 312 12 313 165 1.4 0 1.6 1.4 01/17/2006 23:20:00 2.2 0.3 3 1.5 2.2 0.3 3 1.5 2 0.3 2.6 1.1 315 6 309 165 1.2 0 1.6 1.1 01/17/2006 23:30:00 2.3 0.3 3 1.5 2.2 0.3 3 1.5 2.2 0.3 3 1.5 317 5 307 165 1.1 0 1.4 0.9 01/17/2006 23:40:00 2.8 0.4 3.8 1.9 2.8 0.4 3.8 1.9 2.5 0.4 3.4 1.9 310 5 302 165 0.8 0 1.4 0.9 01/17/2006 23:50:00 3 0.3 3.4 2.3 3 0.3 3.8 2.3 2.8 0.3 3.4 1.9 311 3 307 165 0.7 0 0.9 0.4 01/18/2006 00:00:00 3.7 0.6 4.9 2.3 3.6 0.6 4.9 2.3 3 0.4 4.2 1.9 306 8 295 165 0.5 0 0.7 0.2 01/18/2006 00:10:00 4.4 0.4 5.3 3.4 4.4 0.4 5.3 3.4 3.3 0.4 4.6 2.3 303 5 300 165 0.3 0.1 0.7 0.2 01/18/2006 00:20:00 4.1 0.4 5.3 3.4 4.1 0.4 4.9 3.4 3 0.4 4.6 1.9 304 3 305 165 0.2 0 0.2 0.2 01/18/2006 00:30:00 4.2 0.6 5.3 3 4.2 0.6 5.7 3 3.7 0.6 4.9 2.3 290 5 298 165 0.2 0 0.4 0.2 01/18/2006 00:40:00 5 0.4 6.1 3.8 4.9 0.4 6.1 3.8 4.2 0.6 5.7 3 308 5 313 165 -0.2 0.2 0.2 -0.5 01/18/2006 00:50:00 4.6 0.5 5.7 3.4 4.6 0.5 5.7 3.4 4.3 0.6 5.3 2.6 311 5 315 165 -0.3 0 -0.1 -0.5 01/18/2006 01:00:00 5 0.9 6.8 3 4.9 0.9 6.8 3 4 0.9 7.2 2.3 307 5 320 165 0.1 0 0.2 -0.1 01/18/2006 01:10:00 5.5 0.3 6.1 4.9 5.5 0.3 6.5 4.6 4.7 0.6 6.1 3.4 310 6 304 165 -0.2 0 -0.1 -0.3 01/18/2006 01:20:00 4.8 0.3 5.7 4.2 4.7 0.4 5.7 3.8 4.6 0.3 5.3 3.4 314 5 307 165 -0.2 0 -0.1 -0.3 01/18/2006 01:30:00 5 0.6 6.5 3.4 5 0.6 6.5 3.4 4.4 0.5 5.7 3 309 6 306 165 -0.2 0 0.2 -0.3 01/18/2006 01:40:00 4.8 0.7 6.5 1.9 4.7 0.7 6.1 1.9 4.4 0.7 6.5 2.6 312 9 319 165 0.2 0.1 0.7 -0.1 01/18/2006 01:50:00 5.3 0.7 7.6 3.8 5.3 0.7 7.6 3.8 4.5 0.9 7.2 2.6 305 8 305 165 0.5 0 0.7 0.2 01/18/2006 02:00:00 5.6 0.6 7.2 4.2 5.5 0.6 7.2 4.2 4.7 0.8 7.2 2.6 306 8 313 165 0.8 0.1 0.9 0.7 01/18/2006 02:10:00 5 0.6 6.5 3.8 4.9 0.6 6.5 3.8 4.3 0.6 5.7 2.6 309 7 310 165 0.8 0 0.9 0.7 01/18/2006 02:20:00 4.2 0.8 6.5 2.3 4.1 0.8 6.5 2.3 4 0.8 6.1 2.3 319 11 301 165 0.8 0.1 1.1 0.7 01/18/2006 02:30:00 3 0.6 4.6 1.1 2.9 0.7 4.6 1.1 2.5 0.7 4.2 1.1 306 11 309 165 0.9 0 1.1 0.9 01/18/2006 02:40:00 3.2 0.7 4.6 1.1 3.2 0.7 4.6 1.1 2.8 0.7 4.2 1.5 284 11 288 165 0.7 0.1 0.9 0.2 01/18/2006 02:50:00 3.4 1.2 6.1 1.1 3.5 1.2 6.1 1.1 3.1 1.2 6.1 0.7 261 22 287 165 0 0 0.7 -0.3 01/18/2006 03:00:00 5.5 0.4 6.5 4.6 5.5 0.4 6.5 4.6 4.6 0.7 6.1 3 293 5 292 165 0.2 0 0.2 -0.1 01/18/2006 03:10:00 5.5 0.5 6.5 4.2 5.4 0.5 6.5 4.2 4.3 0.5 6.5 3 303 5 297 165 0.4 0 0.9 0.2 01/18/2006 03:20:00 4.4 0.4 5.3 3.4 4.4 0.4 5.3 3.4 3.4 0.5 4.6 2.3 300 4 298 165 0.8 0 0.9 0.7 01/18/2006 03:30:00 4 0.4 4.9 3 4 0.4 4.9 3 3.1 0.6 4.6 1.9 297 4 294 165 0.4 0.1 0.9 0.2 01/18/2006 03:40:00 5 0.6 6.5 3.4 5 0.6 6.5 3.4 4 0.7 6.1 2.3 301 6 308 165 0.2 0 0.2 -0.1 01/18/2006 03:50:00 5.1 0.5 6.5 3.8 5.1 0.5 6.5 3.4 3.9 0.5 4.9 2.6 301 4 297 165 -0.1 0 0.2 -0.1 01/18/2006 04:00:00 5.9 0.5 7.2 4.6 6 0.5 7.2 4.2 4.5 0.6 6.1 3 296 4 293 165 0 0 0.2 -0.3 01/18/2006 04:10:00 5.8 0.5 7.2 4.6 5.7 0.5 7.2 4.2 4.9 0.6 6.5 3.4 307 5 291 165 0 0 0.2 -0.1 01/18/2006 04:20:00 6.6 0.7 8.4 4.9 6.6 0.7 8.4 4.9 5.1 0.6 7.2 3.4 302 6 303 165 -0.2 0 -0.1 -0.3 01/18/2006 04:30:00 6 0.5 7.6 4.9 6 0.5 7.6 4.9 4.7 0.7 7.2 3.4 297 7 290 165 0 0 0.2 -0.1 01/18/2006 04:40:00 5.2 1 7.2 3 5.2 1 7.2 3 4 0.8 6.8 1.9 300 7 298 165 0.1 0 0.2 -0.1 01/18/2006 04:50:00 3.8 0.7 5.7 2.3 3.8 0.7 5.7 1.9 3.4 0.6 4.6 2.3 309 11 296 165 -0.1 0 0.2 -0.3 01/18/2006 05:00:00 5.1 0.6 7.2 3.8 5 0.6 7.6 3.8 4.2 0.7 6.8 3 302 7 298 165 -0.2 0 -0.1 -0.3 01/18/2006 05:10:00 6.3 0.5 7.6 4.9 6.3 0.5 7.2 4.6 5 0.7 7.2 2.6 295 4 300 165 -0.3 0 -0.1 -0.5 01/18/2006 05:20:00 5.9 0.6 7.2 4.6 5.9 0.6 7.2 4.2 4.3 0.6 6.5 3 300 4 297 165 -0.3 0 -0.3 -0.5 01/18/2006 05:30:00 4.7 0.5 6.1 3.4 4.6 0.6 6.1 3.4 3.6 0.5 5.3 2.6 303 5 300 165 -0.3 0 -0.1 -0.5 01/18/2006 05:40:00 3.7 0.5 4.9 2.3 3.6 0.5 4.9 1.9 2.8 0.5 4.6 1.5 299 6 294 165 -0.2 0 -0.1 -0.3 01/18/2006 05:50:00 3.5 0.6 4.9 2.3 3.5 0.6 4.9 1.9 3.1 0.7 4.9 1.5 310 7 307 165 -0.3 0 -0.1 -0.3 01/18/2006 06:00:00 3.2 0.6 4.2 1.5 3.1 0.6 4.2 1.9 2.9 0.4 3.8 1.9 314 9 302 165 0 0 0.2 -0.3 01/18/2006 06:10:00 2.7 0.4 3.8 1.5 2.6 0.4 3.8 1.5 2.4 0.5 4.6 1.5 306 8 308 165 0.1 0 0.2 -0.1 01/18/2006 06:20:00 2.1 0.4 3 1.5 2 0.4 3 1.1 1.8 0.4 3 0.7 304 6 307 165 -0.1 0 0.2 -0.3 01/18/2006 06:30:00 1.6 0.3 2.3 0.7 1.4 0.4 2.3 0.4 1.5 0.3 2.3 0.7 318 7 307 165 -0.3 0 -0.1 -0.3 01/18/2006 06:40:00 0.9 0.4 1.9 0.4 0.7 0.4 1.5 0.4 0.8 0.3 1.9 0.4 312 10 295 165 -0.2 0 -0.1 -0.3 01/18/2006 06:50:00 1.4 0.3 1.9 0.7 1.3 0.3 1.9 0.4 1 0.3 1.9 0.4 298 4 299 165 0.1 0 0.2 -0.1 01/18/2006 07:00:00 0.6 0.3 1.5 0.4 0.6 0.4 1.5 0.4 0.5 0.3 1.5 0.4 206 64 161 165 -0.1 0.2 0.2 -0.5 01/18/2006 07:10:00 0.6 0.4 1.9 0.4 0.6 0.4 1.9 0.4 0.6 0.4 2.3 0.4 205 17 215 165 -0.4 0 -0.3 -0.5 01/18/2006 07:20:00 0.4 0 0.7 0.4 0.4 0 0.7 0.4 0.4 0 0.7 0.4 198 33 208 165 -0.8 0.1 -0.5 -0.8 01/18/2006 07:30:00 1.7 0.6 3 0.4 1.6 0.6 2.6 0.4 1.3 0.7 2.6 0.4 279 8 284 165 -0.8 0.1 -0.5 -0.8 01/18/2006 07:40:00 1.9 0.4 2.6 1.1 1.7 0.4 2.6 1.1 1.7 0.4 2.6 1.1 276 4 278 165 -0.2 0 -0.1 -0.5 01/18/2006 07:50:00 2 0.3 2.6 1.1 2 0.3 3 1.1 1.9 0.3 2.6 1.1 282 4 282 165 -0.3 0 -0.1 -0.3 01/18/2006 08:00:00 2.7 0.2 3 1.9 2.6 0.2 3 2.3 2.2 0.3 3 1.1 290 3 288 165 -0.3 0 -0.3 -0.5 01/18/2006 08:10:00 1.8 0.4 3 1.1 1.8 0.4 3 0.7 1.3 0.4 2.3 0.4 295 4 287 165 -0.5 0 -0.3 -0.5 01/18/2006 08:20:00 1.3 0.3 1.9 0.7 1.1 0.3 1.9 0.4 1 0.3 1.9 0.4 292 1 292 165 -0.5 0 -0.3 -0.5 01/18/2006 08:30:00 1.2 0.3 1.9 0.7 0.8 0.4 1.9 0.4 1.1 0.3 1.9 0.4 314 15 297 165 -0.5 0 -0.3 -0.8 01/18/2006 08:40:00 1.3 0.3 1.9 0.7 0.7 0.4 1.9 0.4 1.4 0.3 1.9 0.7 353 5 357 165 -1 0.1 -0.5 -1.4 01/18/2006 08:50:00 1.8 0.2 2.3 1.5 1.1 0.3 1.9 0.4 1.8 0.2 2.3 1.5 353 7 354 165 -1.6 0 -1.2 -1.7 01/18/2006 09:00:00 1.7 0.2 2.3 1.1 1.1 0.3 1.9 0.4 2 0.2 2.3 1.5 11 3 8 165 -1.4 0 -1.2 -1.7 01/18/2006 09:10:00 1.4 0.3 1.9 0.7 1 0.4 1.9 0.4 1.8 0.3 2.6 1.1 13 6 13 165 -1.1 0 -1 -1.4 01/18/2006 09:20:00 0.7 0.4 1.9 0.4 0.5 0.2 1.9 0.4 1.2 0.4 2.3 0.4 6 17 354 165 -0.9 0 -0.8 -1.2 01/18/2006 09:30:00 0.4 0.1 1.1 0.4 0.4 0 0.7 0.4 0.4 0.2 1.5 0.4 299 53 15 165 -0.8 0 -0.5 -0.8 01/18/2006 09:40:00 0.5 0.3 1.5 0.4 0.4 0.2 1.1 0.4 0.4 0.1 1.1 0.4 156 72 316 165 -0.8 0.1 -0.5 -0.8 01/18/2006 09:50:00 1.3 0.7 2.6 0.4 1.2 0.7 2.6 0.4 1 0.6 2.3 0.4 287 7 289 165 -0.5 0.1 -0.3 -0.8 01/18/2006 10:00:00 2.2 0.3 3 1.5 2.2 0.3 2.6 1.1 1.6 0.5 3 0.4 297 5 301 165 -0.6 0.1 -0.5 -0.8 01/18/2006 10:10:00 1.6 0.3 2.3 0.7 1.5 0.3 2.3 0.7 0.9 0.3 1.5 0.4 290 5 293 165 -0.9 0 -0.5 -1 01/18/2006 10:20:00 0.7 0.3 1.5 0.4 0.6 0.3 1.5 0.4 0.7 0.4 1.5 0.4 213 56 282 165 -0.9 0 -0.8 -1 01/18/2006 10:30:00 0.4 0.2 1.1 0.4 0.4 0 0.4 0.4 0.4 0.1 1.1 0.4 139 2 138 165 -0.9 0 -0.5 -1 01/18/2006 10:40:00 0.9 0.3 1.5 0.4 0.8 0.3 1.1 0.4 0.6 0.3 1.5 0.4 148 4 148 165 -0.9 0 -0.8 -1 01/18/2006 10:50:00 0.5 0.3 1.5 0.4 0.5 0.3 1.5 0.4 0.4 0.2 1.1 0.4 174 49 245 165 -0.8 0 -0.8 -0.8 01/18/2006 11:00:00 1.5 0.4 2.3 0.4 1.5 0.4 2.3 0.4 1.2 0.5 2.3 0.4 271 12 262 165 -0.6 0 -0.5 -0.8 01/18/2006 11:10:00 1.2 0.3 1.9 0.4 1.1 0.4 1.5 0.4 0.9 0.3 1.5 0.4 282 8 276 165 -0.5 0 -0.3 -0.5 01/18/2006 11:20:00 1.3 0.3 1.9 0.4 1.3 0.3 1.9 0.4 0.6 0.3 1.5 0.4 296 4 299 165 -0.3 0 -0.1 -0.5 01/18/2006 11:30:00 0.4 0.1 1.1 0.4 0.4 0.1 1.1 0.4 0.4 0 0.4 0.4 281 86 282 165 0.3 0.1 0.7 -0.1 01/18/2006 11:40:00 0.4 0.1 1.5 0.4 0.4 0.1 1.5 0.4 0.4 0.1 1.1 0.4 117 9 110 165 0.4 0 0.7 0.2 01/18/2006 11:50:00 1.2 0.4 2.3 0.4 1.1 0.4 1.9 0.4 1.4 0.4 2.3 0.4 115 7 121 165 0 0 0.7 -0.1 01/18/2006 12:00:00 0.8 0.4 1.9 0.4 0.8 0.4 1.9 0.4 1.1 0.5 2.3 0.4 116 8 124 165 0.6 0.3 1.1 -0.1 01/18/2006 12:10:00 0.4 0.2 1.5 0.4 0.4 0.2 1.5 0.4 0.6 0.4 1.9 0.4 130 12 135 165 -0.1 0.1 0.7 -0.3 01/18/2006 12:20:00 0.8 0.4 1.9 0.4 0.5 0.3 1.5 0.4 0.9 0.4 1.9 0.4 156 9 160 165 -0.3 0 -0.1 -0.3 01/18/2006 12:30:00 0.7 0.4 1.5 0.4 0.5 0.3 1.5 0.4 0.8 0.5 1.9 0.4 152 5 156 165 -0.3 0 -0.1 -0.3 01/18/2006 12:40:00 0.5 0.3 1.5 0.4 0.4 0.2 1.1 0.4 0.6 0.3 1.5 0.4 133 9 128 165 -0.3 0 -0.1 -0.3 01/18/2006 12:50:00 0.4 0.1 0.7 0.4 0.4 0 0.7 0.4 0.4 0 0.7 0.4 127 0 127 165 -0.3 0 -0.1 -0.3 01/18/2006 13:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 127 0 165 165 -0.1 0 0.2 -0.3 01/18/2006 13:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 127 0 165 165 0.1 0 0.2 -0.1 01/18/2006 13:20:00 0.4 0.2 1.5 0.4 0.4 0.2 1.5 0.4 0.4 0.2 1.1 0.4 189 32 165 165 0 0 0.2 -0.1 01/18/2006 13:30:00 0.4 0.1 1.1 0.4 0.4 0.1 0.7 0.4 0.5 0.3 1.5 0.4 148 17 151 165 -0.2 0 -0.1 -0.3 01/18/2006 13:40:00 0.4 0 0.7 0.4 0.4 0 0.4 0.4 0.4 0 0.7 0.4 122 0 122 165 -0.2 0 -0.1 -0.3 01/18/2006 13:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 122 0 165 165 0.2 0.1 0.7 -0.1 01/18/2006 14:00:00 0.4 0.2 1.5 0.4 0.4 0.2 1.5 0.4 0.5 0.3 1.5 0.4 20 72 325 165 1.2 0.3 1.6 0.7 01/18/2006 14:10:00 0.5 0.3 1.5 0.4 0.4 0.2 1.5 0.4 0.5 0.3 1.5 0.4 8 15 334 165 0.7 0 1.1 0.7 01/18/2006 14:20:00 0.6 0.4 1.9 0.4 0.5 0.3 1.5 0.4 0.6 0.4 1.5 0.4 40 28 80 165 0.2 0.2 0.7 -0.3 01/18/2006 14:30:00 0.4 0 0.7 0.4 0.4 0 0.4 0.4 0.4 0.1 1.1 0.4 49 16 39 165 -0.2 0 -0.1 -0.3 01/18/2006 14:40:00 0.4 0.1 1.1 0.4 0.4 0 0.7 0.4 0.5 0.3 1.5 0.4 39 5 39 165 -0.3 0 -0.1 -0.3 01/18/2006 14:50:00 0.9 0.5 2.3 0.4 0.8 0.4 1.9 0.4 1.1 0.5 2.3 0.4 38 5 34 165 -0.3 0 -0.1 -0.3 01/18/2006 15:00:00 1.2 0.5 2.3 0.4 1 0.5 1.9 0.4 1.3 0.5 2.3 0.4 29 14 32 165 -0.3 0 -0.3 -0.5 01/18/2006 15:10:00 1.3 0.3 1.9 0.4 1 0.4 1.9 0.4 1.3 0.4 2.3 0.4 21 7 27 165 -0.3 0 -0.3 -0.5 01/18/2006 15:20:00 1.6 0.3 2.3 0.7 0.9 0.4 1.9 0.4 1.7 0.3 2.3 1.1 8 7 15 165 -0.3 0 -0.3 -0.3 01/18/2006 15:30:00 1.6 0.4 2.3 0.7 1 0.5 2.3 0.4 1.6 0.4 2.6 0.4 10 6 8 165 -0.3 0 -0.3 -0.3 01/18/2006 15:40:00 1.6 0.4 2.6 0.7 1.1 0.5 2.3 0.4 1.9 0.3 2.6 1.1 12 9 22 165 -0.4 0 -0.3 -0.5 01/18/2006 15:50:00 2.3 0.3 3 1.1 1.2 0.5 2.6 0.4 2.3 0.3 3 1.5 357 6 357 165 -0.5 0 -0.3 -0.5 01/18/2006 16:00:00 2.3 0.3 3 1.9 1.8 0.5 2.6 0.4 2.3 0.3 3 1.9 342 11 357 165 -0.5 0 -0.3 -0.8 01/18/2006 16:10:00 2.2 0.3 3 1.5 2 0.3 2.6 1.1 2.2 0.3 2.6 1.5 325 7 327 165 -0.7 0 -0.5 -0.8 01/18/2006 16:20:00 1.8 0.4 2.6 0.7 1.6 0.4 2.3 0.4 1.7 0.3 2.3 0.7 315 8 306 165 -0.9 0 -0.8 -0.8 01/18/2006 16:30:00 1.9 0.4 2.6 1.1 1.7 0.4 2.6 1.1 1.6 0.3 2.6 0.7 305 8 301 165 -0.9 0 -0.8 -1 01/18/2006 16:40:00 1.9 0.4 3 0.7 1.6 0.4 2.6 0.7 1.5 0.5 2.3 0.4 310 10 298 165 -0.9 0 -0.8 -1 01/18/2006 16:50:00 1 0.5 2.3 0.4 0.8 0.4 2.3 0.4 0.7 0.4 1.9 0.4 305 7 291 165 -0.9 0 -0.8 -1 01/18/2006 17:00:00 1.4 0.5 3 0.4 1.2 0.5 2.6 0.4 0.9 0.4 1.9 0.4 305 10 308 165 -0.9 0 -0.8 -1 01/18/2006 17:10:00 0.6 0.4 1.9 0.4 0.5 0.3 1.5 0.4 0.5 0.3 1.5 0.4 299 11 314 165 -1 0 -0.8 -1.2 01/18/2006 17:20:00 1.6 0.4 2.3 0.4 1.4 0.4 2.3 0.4 1.5 0.3 2.3 0.7 316 9 314 165 -1 0 -0.8 -1.2 01/18/2006 17:30:00 1.4 0.3 2.3 0.7 1.2 0.3 2.3 0.4 1.3 0.3 2.3 0.4 307 7 318 165 -1 0 -1 -1.2 01/18/2006 17:40:00 2.1 0.3 2.6 1.1 1.9 0.3 2.6 1.1 2.1 0.3 3 1.1 320 12 317 165 -1.1 0 -0.8 -1.2 01/18/2006 17:50:00 1.9 0.3 2.6 1.1 1.6 0.4 2.3 0.4 1.9 0.3 2.6 1.1 337 8 327 165 -1.2 0 -1 -1.2 01/18/2006 18:00:00 1.9 0.2 2.3 1.5 0.9 0.5 1.9 0.4 1.8 0.2 2.3 1.1 359 10 355 165 -1.2 0 -1 -1.2 01/18/2006 18:10:00 0.5 0.3 1.5 0.4 0.4 0.1 1.5 0.4 0.5 0.3 1.5 0.4 358 6 10 165 -1.2 0 -1 -1.2 01/18/2006 18:20:00 0.4 0.1 0.7 0.4 0.4 0 0.4 0.4 0.4 0.1 1.1 0.4 12 14 22 165 -1.2 0 -1 -1.2 01/18/2006 18:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0.1 1.1 0.4 18 9 165 165 -1 0 -0.8 -1.2 01/18/2006 18:40:00 0.4 0 0.7 0.4 0.4 0 0.4 0.4 0.4 0 0.7 0.4 303 21 297 165 -0.9 0 -0.8 -1 01/18/2006 18:50:00 0.4 0.1 0.7 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 244 58 169 165 -0.9 0 -0.8 -1 01/18/2006 19:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 169 0 165 165 -0.9 0 -0.8 -0.8 01/18/2006 19:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 169 0 165 165 -0.9 0 -0.8 -0.8 01/18/2006 19:20:00 0.7 0.4 1.5 0.4 0.5 0.3 1.1 0.4 0.6 0.3 1.5 0.4 166 5 164 165 -0.9 0 -0.8 -1 01/18/2006 19:30:00 0.4 0.2 1.1 0.4 0.4 0 0.4 0.4 0.5 0.3 1.5 0.4 153 0 153 165 -0.9 0 -0.8 -1 01/18/2006 19:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 153 0 165 165 -0.9 0 -0.8 -1 01/18/2006 19:50:00 0.6 0.3 1.5 0.4 0.5 0.2 1.5 0.4 0.5 0.2 1.5 0.4 301 58 288 165 -1 0 -0.8 -1.2 01/18/2006 20:00:00 1.2 0.4 2.3 0.4 1.2 0.5 2.3 0.4 1 0.4 2.3 0.4 293 5 290 165 -1 0 -0.8 -1.2 01/18/2006 20:10:00 1.1 0.5 1.9 0.4 1.1 0.5 2.3 0.4 1.1 0.5 2.3 0.4 306 2 307 165 -1.2 0 -1 -1.2 01/18/2006 20:20:00 1.7 0.3 2.6 1.1 1.7 0.3 2.3 1.1 1.6 0.3 2.6 0.7 306 7 287 165 -1.2 0 -1 -1.2 01/18/2006 20:30:00 0.7 0.4 1.9 0.4 0.7 0.5 1.9 0.4 0.6 0.4 1.9 0.4 284 22 231 165 -1.2 0 -1 -1.2 01/18/2006 20:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 284 7 165 165 -1.1 0 -1 -1.2 01/18/2006 20:50:00 0.5 0.3 1.1 0.4 0.5 0.3 1.5 0.4 0.6 0.4 1.5 0.4 283 9 293 165 -1.1 0 -1 -1.2 01/18/2006 21:00:00 1.7 0.3 2.3 1.1 1.7 0.3 2.3 1.1 1.9 0.3 2.3 1.1 311 5 309 165 -1.2 0 -1.2 -1.2 01/18/2006 21:10:00 1.8 0.3 2.3 1.1 1.7 0.3 2.6 1.1 2 0.2 2.6 1.5 334 4 324 165 -1.2 0 -1.2 -1.4 01/18/2006 21:20:00 1.9 0.4 2.6 1.1 1.8 0.4 2.6 0.7 2 0.4 2.6 1.5 331 7 334 165 -1.4 0 -1.2 -1.4 01/18/2006 21:30:00 1.3 0.5 2.6 0.4 1 0.4 2.3 0.4 1.6 0.5 2.6 0.7 344 6 354 165 -1.4 0 -1.4 -1.4 01/18/2006 21:40:00 0.7 0.5 2.3 0.4 0.7 0.5 2.3 0.4 0.8 0.6 2.3 0.4 17 76 135 165 -1.4 0 -1.2 -1.4 01/18/2006 21:50:00 1.9 0.4 2.6 1.1 1.9 0.4 2.6 0.7 1.9 0.3 2.6 1.1 127 4 128 165 -1.2 0 -1.2 -1.4 01/18/2006 22:00:00 1.6 0.3 2.3 0.7 1.5 0.3 2.3 0.7 1.6 0.3 2.3 0.7 132 10 133 165 -1.2 0 -1 -1.2 01/18/2006 22:10:00 1.5 0.3 2.3 0.7 1.4 0.3 1.9 0.7 1.7 0.3 2.3 1.1 139 7 139 165 -1.2 0 -1 -1.2 01/18/2006 22:20:00 1.1 0.5 1.9 0.4 0.9 0.5 1.9 0.4 1.3 0.4 1.9 0.4 146 8 137 165 -1.2 0 -1 -1.2 01/18/2006 22:30:00 0.4 0.1 0.7 0.4 0.4 0 0.4 0.4 0.4 0.1 1.1 0.4 156 0 156 165 -1.2 0 -1 -1.4 01/18/2006 22:40:00 0.7 0.4 1.5 0.4 0.6 0.3 1.5 0.4 0.8 0.4 1.5 0.4 4 72 156 165 -1.4 0 -1.2 -1.4 01/18/2006 22:50:00 0.6 0.3 1.1 0.4 0.6 0.3 1.5 0.4 0.8 0.3 1.5 0.4 281 9 290 165 -1.4 0 -1.4 -1.4 01/18/2006 23:00:00 0.4 0 0.7 0.4 0.4 0 0.4 0.4 0.4 0 0.7 0.4 265 0 265 165 -1.4 0 -1.4 -1.7 01/18/2006 23:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 265 0 165 165 -1.5 0 -1.4 -1.4 01/18/2006 23:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 265 0 165 165 -1.6 0 -1.4 -1.7 01/18/2006 23:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 265 0 165 165 -1.6 0 -1.4 -1.7 01/18/2006 23:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0.1 1.1 0.4 296 35 165 165 -1.6 0 -1.4 -1.7 01/18/2006 23:50:00 1.3 0.8 2.6 0.4 0.9 0.5 1.9 0.4 1.5 0.7 2.6 0.4 0 17 11 165 -1.7 0 -1.4 -1.9 01/19/2006 00:00:00 2.2 0.3 3 1.5 1.3 0.4 2.3 0.4 2.1 0.3 3 1.5 9 6 10 165 -1.8 0 -1.7 -1.9 01/19/2006 00:10:00 2 0.3 3 1.5 1.7 0.4 3 0.7 2.2 0.3 2.6 1.1 17 9 31 165 -1.8 0 -1.7 -1.9 01/19/2006 00:20:00 2.3 0.3 3 1.5 1.5 0.6 2.6 0.4 2.7 0.3 3.4 1.9 9 6 11 165 -1.7 0 -1.7 -1.9 01/19/2006 00:30:00 2.1 0.4 3 1.1 1.2 0.5 3 0.4 2.3 0.3 3 1.5 359 6 358 165 -1.7 0 -1.4 -1.9 01/19/2006 00:40:00 0.5 0.3 1.5 0.4 0.5 0.2 1.5 0.4 0.8 0.5 2.3 0.4 11 5 9 165 -1.6 0 -1.4 -1.7 01/19/2006 00:50:00 1 0.6 2.3 0.4 0.6 0.3 1.5 0.4 1.3 0.6 2.6 0.4 355 15 0 165 -1.6 0 -1.4 -1.7 01/19/2006 01:00:00 1.1 0.4 2.3 0.4 1.1 0.4 1.9 0.4 1.4 0.4 2.3 0.4 322 20 341 165 -1.7 0 -1.4 -1.9 01/19/2006 01:10:00 0.5 0.3 1.5 0.4 0.4 0.2 1.5 0.4 0.8 0.4 1.9 0.4 334 30 326 165 -1.8 0 -1.7 -1.9 01/19/2006 01:20:00 1 0.4 1.9 0.4 1 0.5 2.3 0.4 1.2 0.4 1.9 0.4 313 15 343 165 -1.9 0 -1.7 -1.9 01/19/2006 01:30:00 1 0.5 2.3 0.4 1.1 0.6 2.6 0.4 1.3 0.6 2.6 0.4 306 18 285 165 -1.9 0 -1.7 -1.9 01/19/2006 01:40:00 1.7 0.7 3 0.4 1.7 0.7 3 0.4 1.9 0.5 3 0.4 302 16 287 165 -1.8 0 -1.7 -1.9 01/19/2006 01:50:00 1.2 0.5 2.3 0.4 1.3 0.4 2.3 0.4 1.2 0.3 1.9 0.4 304 5 301 165 -1.9 0 -1.7 -1.9 01/19/2006 02:00:00 1.9 0.4 2.6 0.7 2 0.4 2.6 1.1 1.9 0.4 3 0.7 293 6 295 165 -1.8 0 -1.7 -1.9 01/19/2006 02:10:00 1.7 0.5 3 0.4 1.8 0.5 3 0.4 1.9 0.5 3 0.7 289 7 289 165 -1.7 0 -1.7 -1.9 01/19/2006 02:20:00 1.9 0.5 3.4 0.7 2 0.5 3.4 0.7 1.8 0.6 3.4 0.7 297 7 300 165 -1.7 0 -1.7 -1.9 01/19/2006 02:30:00 2.5 0.5 3.8 1.5 2.6 0.5 4.2 1.5 2.2 0.5 3.4 1.1 301 7 302 165 -1.7 0 -1.4 -1.9 01/19/2006 02:40:00 1.9 0.5 3.4 0.7 2 0.5 3.4 0.7 1.8 0.4 2.6 0.4 306 10 295 165 -1.7 0 -1.4 -1.9 01/19/2006 02:50:00 2.5 0.5 3.8 1.5 2.5 0.5 3.8 1.5 2.4 0.5 4.2 1.5 303 10 291 165 -1.7 0 -1.4 -1.9 01/19/2006 03:00:00 3.3 0.5 4.6 2.3 3.4 0.5 4.6 2.3 3.1 0.6 4.6 1.5 292 6 282 165 -1.8 0 -1.7 -1.9 01/19/2006 03:10:00 2.9 0.4 3.8 1.9 2.9 0.4 3.8 1.9 2.5 0.5 3.8 1.1 304 8 305 165 -1.9 0 -1.7 -1.9 01/19/2006 03:20:00 2.6 0.7 4.6 1.5 2.6 0.7 4.2 1.5 2.2 0.6 3.4 0.7 304 11 300 165 -1.9 0 -1.7 -1.9 01/19/2006 03:30:00 3.1 0.5 4.2 1.5 3.1 0.5 4.2 1.5 2.9 0.5 3.8 1.5 291 6 292 165 -1.8 0 -1.7 -1.9 01/19/2006 03:40:00 2.9 0.4 3.8 1.9 3 0.4 4.2 1.9 2.8 0.5 4.2 1.5 293 7 295 165 -1.7 0 -1.7 -1.9 01/19/2006 03:50:00 2.7 0.4 3.4 1.5 2.7 0.4 3.4 1.9 2.4 0.6 3.8 0.7 296 10 293 165 -1.8 0 -1.7 -1.9 01/19/2006 04:00:00 2.5 0.4 3.4 1.5 2.6 0.4 3.8 1.5 2.4 0.5 3.8 1.1 290 8 279 165 -1.8 0 -1.7 -1.9 01/19/2006 04:10:00 1.8 0.5 3 0.7 1.8 0.5 3 0.7 1.7 0.4 2.6 0.7 302 8 286 165 -1.7 0 -1.4 -1.7 01/19/2006 04:20:00 1 0.4 1.9 0.4 0.9 0.3 1.5 0.4 1.1 0.3 1.9 0.4 315 8 307 165 -1.7 0 -1.4 -1.9 01/19/2006 04:30:00 1.1 0.4 2.3 0.4 1.1 0.5 2.3 0.4 1.2 0.4 2.3 0.4 326 12 310 165 -1.7 0 -1.7 -1.9 01/19/2006 04:40:00 0.8 0.3 1.5 0.4 0.7 0.3 1.5 0.4 1 0.3 1.5 0.4 321 12 342 165 -1.7 0 -1.4 -1.9 01/19/2006 04:50:00 0.5 0.2 1.5 0.4 0.4 0.2 1.5 0.4 0.7 0.3 1.5 0.4 318 6 313 165 -1.7 0 -1.7 -1.9 01/19/2006 05:00:00 0.4 0 0.7 0.4 0.4 0.1 0.7 0.4 0.6 0.4 1.5 0.4 301 18 295 165 -1.7 0 -1.4 -1.9 01/19/2006 05:10:00 0.4 0.2 1.5 0.4 0.4 0.2 1.5 0.4 0.6 0.3 1.9 0.4 277 12 312 165 -1.7 0 -1.7 -1.9 01/19/2006 05:20:00 0.5 0.3 1.5 0.4 0.5 0.3 1.9 0.4 0.5 0.3 1.9 0.4 299 7 321 165 -1.9 0 -1.7 -1.9 01/19/2006 05:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 301 0 165 165 -1.9 0 -1.7 -1.9 01/19/2006 05:40:00 0.4 0.1 0.7 0.4 0.4 0 0.4 0.4 0.4 0.2 1.1 0.4 301 0 301 165 -1.8 0 -1.7 -1.9 01/19/2006 05:50:00 0.4 0.2 1.1 0.4 0.4 0.1 1.1 0.4 0.4 0 0.7 0.4 338 32 5 165 -2 0 -1.9 -2.1 01/19/2006 06:00:00 0.4 0.2 1.1 0.4 0.4 0.1 1.1 0.4 0.7 0.4 1.5 0.4 348 20 315 165 -2 0 -1.9 -2.1 01/19/2006 06:10:00 0.4 0.1 1.1 0.4 0.4 0.1 1.1 0.4 0.4 0.2 1.1 0.4 324 13 314 165 -2 0 -1.9 -1.9 01/19/2006 06:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 344 0 165 165 -2 0 -1.9 -1.9 01/19/2006 06:30:00 0.4 0 0.7 0.4 0.4 0 0.4 0.4 0.4 0 0.7 0.4 343 6 328 165 -1.9 0 -1.9 -1.9 01/19/2006 06:40:00 1 0.6 2.6 0.4 1 0.7 2.6 0.4 1.1 0.6 2.6 0.4 298 11 291 165 -2 0 -1.7 -2.1 01/19/2006 06:50:00 0.8 0.4 1.5 0.4 0.7 0.4 1.5 0.4 1.1 0.4 1.9 0.4 278 14 280 165 -2.1 0 -1.9 -2.1 01/19/2006 07:00:00 0.6 0.3 1.5 0.4 0.5 0.2 1.1 0.4 0.7 0.3 1.5 0.4 290 10 301 165 -2 0 -1.9 -2.1 01/19/2006 07:10:00 0.7 0.3 1.5 0.4 0.5 0.2 1.1 0.4 0.9 0.4 1.9 0.4 315 30 323 165 -2.1 0 -1.9 -2.1 01/19/2006 07:20:00 0.5 0.3 1.1 0.4 0.4 0.2 1.1 0.4 0.7 0.3 1.5 0.4 22 10 0 165 -2.1 0 -2.1 -2.1 01/19/2006 07:30:00 0.4 0.1 1.1 0.4 0.4 0 0.7 0.4 0.4 0.2 1.1 0.4 28 2 28 165 -2 0 -1.9 -2.1 01/19/2006 07:40:00 1.4 0.5 2.3 0.4 1.4 0.6 2.3 0.4 1.9 0.5 3 0.7 25 15 7 165 -2 0 -1.9 -2.1 01/19/2006 07:50:00 0.5 0.2 1.1 0.4 0.5 0.2 1.1 0.4 1 0.4 1.5 0.4 29 4 28 165 -2 0 -1.9 -2.1 01/19/2006 08:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.6 0.3 1.5 0.4 46 22 165 165 -2 0 -1.9 -2.1 01/19/2006 08:10:00 0.5 0.3 1.5 0.4 0.5 0.3 1.9 0.4 0.6 0.4 2.3 0.4 51 26 31 165 -2 0 -1.9 -2.1 01/19/2006 08:20:00 0.4 0 0.7 0.4 0.4 0 0.7 0.4 0.4 0.2 1.1 0.4 24 10 34 165 -2.1 0 -1.9 -2.1 01/19/2006 08:30:00 0.4 0.1 1.1 0.4 0.4 0.1 1.1 0.4 0.6 0.4 1.9 0.4 324 41 294 165 -2.2 0 -1.9 -2.1 01/19/2006 08:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0.1 1.1 0.4 37 33 165 165 -2.1 0 -2.1 -2.1 01/19/2006 08:50:00 0.7 0.4 1.5 0.4 0.7 0.4 1.5 0.4 0.7 0.3 1.5 0.4 302 5 297 165 -2.1 0 -1.9 -2.1 01/19/2006 09:00:00 1.1 0.7 2.3 0.4 1 0.8 2.6 0.4 1.4 0.8 2.6 0.4 329 12 334 165 -2.1 0 -1.9 -2.1 01/19/2006 09:10:00 0.6 0.5 1.9 0.4 0.6 0.5 2.3 0.4 0.6 0.5 2.3 0.4 310 2 314 165 -2.2 0 -2.1 -2.1 01/19/2006 09:20:00 0.5 0.2 1.1 0.4 0.4 0 0.4 0.4 0.7 0.4 1.5 0.4 309 0 309 165 -2.1 0 -1.9 -2.1 01/19/2006 09:30:00 1.1 0.4 1.9 0.4 1.1 0.5 1.9 0.4 1.3 0.3 1.9 0.7 305 5 297 165 -2.1 0 -1.9 -2.1 01/19/2006 09:40:00 0.8 0.3 1.5 0.4 0.8 0.4 1.9 0.4 1.1 0.4 1.9 0.4 317 3 310 165 -2.2 0 -1.9 -2.1 01/19/2006 09:50:00 0.5 0.2 1.1 0.4 0.4 0.1 1.1 0.4 0.5 0.2 1.1 0.4 294 5 308 165 -2.1 0 -1.9 -2.1 01/19/2006 10:00:00 1.3 0.5 2.3 0.4 1.4 0.5 2.3 0.4 1.2 0.5 2.3 0.4 299 6 300 165 -2.1 0 -1.9 -2.1 01/19/2006 10:10:00 1.7 0.3 2.6 0.7 1.8 0.3 2.6 0.7 1.5 0.3 2.3 0.4 291 4 277 165 -2.1 0 -1.9 -2.1 01/19/2006 10:20:00 1.8 0.3 2.6 0.7 1.9 0.3 2.6 1.1 1.5 0.4 2.3 0.7 301 5 292 165 -2.1 0 -1.9 -2.1 01/19/2006 10:30:00 0.9 0.4 1.9 0.4 0.9 0.4 1.9 0.4 0.9 0.5 2.3 0.4 283 8 296 165 -2.1 0 -1.9 -2.1 01/19/2006 10:40:00 0.4 0.1 0.7 0.4 0.4 0 0.4 0.4 0.4 0 0.7 0.4 221 47 172 165 -1.9 0 -1.7 -2.1 01/19/2006 10:50:00 0.4 0.1 1.1 0.4 0.4 0.1 0.7 0.4 0.5 0.3 1.5 0.4 197 22 172 165 -1.6 0 -1.4 -1.7 01/19/2006 11:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 226 20 165 165 -1.5 0 -1.4 -1.7 01/19/2006 11:10:00 0.7 0.4 1.5 0.4 0.7 0.5 1.9 0.4 0.9 0.5 1.9 0.4 182 51 159 165 -1.6 0 -1.4 -1.7 01/19/2006 11:20:00 0.7 0.4 1.9 0.4 0.7 0.4 1.9 0.4 0.9 0.5 1.9 0.4 154 5 148 165 -1.6 0 -1.4 -1.7 01/19/2006 11:30:00 1.3 0.3 2.3 0.4 1.4 0.3 2.3 0.7 1.5 0.3 2.3 0.4 118 12 128 165 -1.6 0 -1.4 -1.7 01/19/2006 11:40:00 0.6 0.3 1.5 0.4 0.6 0.4 1.5 0.4 0.8 0.4 1.5 0.4 133 7 123 165 -1.7 0 -1.4 -1.9 01/19/2006 11:50:00 0.6 0.5 1.9 0.4 0.7 0.5 2.3 0.4 0.9 0.5 2.3 0.4 123 6 121 165 -1.6 0 -1.4 -1.7 01/19/2006 12:00:00 0.5 0.3 2.6 0.4 0.5 0.3 2.3 0.4 0.7 0.5 2.3 0.4 131 0 128 165 -1.7 0 -1.4 -1.9 01/19/2006 12:10:00 0.4 0.2 1.5 0.4 0.4 0.2 1.5 0.4 0.5 0.3 1.9 0.4 110 18 111 165 -1.7 0 -1.4 -1.9 01/19/2006 12:20:00 1.2 0.6 2.6 0.4 1.3 0.6 3 0.4 1.5 0.5 2.6 0.4 54 7 56 165 -1.7 0 -1.4 -1.9 01/19/2006 12:30:00 1.3 0.5 2.3 0.4 1.5 0.4 2.3 0.4 1.8 0.3 2.6 1.1 50 8 51 165 -2 0 -1.7 -2.1 01/19/2006 12:40:00 1.1 0.5 2.6 0.4 1.2 0.5 2.6 0.4 1.8 0.4 2.6 0.7 46 9 48 165 -2.1 0 -1.9 -2.1 01/19/2006 12:50:00 1 0.6 2.3 0.4 1.1 0.6 2.3 0.4 1.5 0.7 2.6 0.4 39 23 51 165 -2.1 0 -1.9 -2.1 01/19/2006 13:00:00 1.3 0.6 2.6 0.4 1.4 0.7 2.6 0.4 1.8 0.4 3 0.7 61 11 41 165 -2.1 0 -1.9 -2.1 01/19/2006 13:10:00 0.6 0.5 1.9 0.4 0.7 0.5 1.9 0.4 1.1 0.6 2.3 0.4 48 14 43 165 -2.1 0 -1.9 -2.1 01/19/2006 13:20:00 1.6 0.5 2.3 0.4 1.6 0.5 2.6 0.4 1.8 0.4 2.6 0.4 35 11 43 165 -2.1 0 -2.1 -2.1 01/19/2006 13:30:00 1.6 0.3 2.6 0.7 1.6 0.4 2.6 0.4 1.9 0.3 2.6 1.1 28 10 43 165 -2.1 0 -2.1 -2.1 01/19/2006 13:40:00 1.7 0.4 2.6 0.4 1.4 0.5 2.3 0.4 2 0.4 3 0.7 10 8 1 165 -2.1 0 -1.9 -2.1 01/19/2006 13:50:00 2.1 0.4 3 1.1 1.7 0.5 2.6 0.4 2.3 0.4 3 1.1 12 6 16 165 -2 0 -1.9 -1.9 01/19/2006 14:00:00 2.4 0.4 3.4 1.5 2.2 0.5 3.4 0.7 2.6 0.4 3.8 1.5 18 10 21 165 -2 0 -1.9 -2.1 01/19/2006 14:10:00 3 0.4 3.8 1.9 3 0.4 3.8 1.9 3.2 0.5 4.2 1.9 28 3 23 165 -2.2 0 -2.1 -2.4 01/19/2006 14:20:00 3.2 0.3 3.8 2.3 3.2 0.4 4.2 2.3 3.4 0.4 4.2 1.9 31 5 29 165 -2.4 0 -2.1 -2.6 01/19/2006 14:30:00 2.7 0.4 3.4 1.1 2.7 0.4 3.8 1.1 2.9 0.4 3.8 1.9 32 4 31 165 -2.4 0 -2.1 -2.6 01/19/2006 14:40:00 1.7 0.4 2.6 0.4 1.8 0.4 2.6 0.4 2 0.4 3 1.1 38 7 43 165 -2.4 0 -2.1 -2.6 01/19/2006 14:50:00 1.6 0.5 2.6 0.4 1.6 0.5 2.6 0.4 2.1 0.4 2.6 1.1 24 9 19 165 -2.4 0 -2.1 -2.6 01/19/2006 15:00:00 2.1 0.4 2.6 0.7 2.1 0.4 3 0.7 2.4 0.3 3 1.5 25 7 23 165 -2.4 0 -2.1 -2.6 01/19/2006 15:10:00 2 0.5 3 0.7 1.9 0.6 3 0.4 2.2 0.4 3 1.1 23 8 20 165 -2.4 0 -2.1 -2.6 01/19/2006 15:20:00 1.9 0.4 3 0.7 1.8 0.5 2.6 0.4 2.1 0.4 3 1.1 24 7 14 165 -2.4 0 -2.1 -2.6 01/19/2006 15:30:00 2.2 0.3 2.6 1.5 2.3 0.3 3 1.5 2.4 0.3 3 1.5 42 6 36 165 -2.5 0 -2.1 -2.6 01/19/2006 15:40:00 1.7 0.4 2.6 1.1 1.8 0.4 2.6 0.7 1.9 0.4 2.6 1.1 42 8 46 165 -2.5 0 -2.6 -2.6 01/19/2006 15:50:00 2.3 0.4 3 1.5 2.5 0.4 3.4 1.5 2.6 0.4 3.4 1.5 36 5 39 165 -2.5 0 -2.4 -2.6 01/19/2006 16:00:00 2.7 0.5 3.8 1.5 2.8 0.4 3.8 1.9 2.9 0.5 3.8 1.9 34 5 27 165 -2.6 0 -2.6 -2.8 01/19/2006 16:10:00 4 0.6 5.3 2.6 4 0.6 5.3 2.6 4.2 0.6 5.7 2.6 31 4 36 165 -2.8 0 -2.6 -2.8 01/19/2006 16:20:00 5 0.3 5.7 4.2 5.1 0.3 5.7 4.2 5.2 0.3 6.1 4.2 32 3 32 165 -2.8 0 -2.6 -3 01/19/2006 16:30:00 4.3 0.4 5.3 3 4.3 0.5 5.3 2.6 4.7 0.5 5.7 3.4 26 4 29 165 -2.9 0 -2.8 -3 01/19/2006 16:40:00 4 0.4 4.9 2.6 3.8 0.6 4.9 1.9 4.3 0.4 4.9 2.6 23 6 27 165 -3 0 -2.8 -3 01/19/2006 16:50:00 3.4 0.4 4.6 2.6 3 0.5 4.6 1.5 3.8 0.4 4.9 2.6 17 6 31 165 -3 0 -2.8 -3 01/19/2006 17:00:00 3 0.5 4.2 1.9 2.5 0.8 4.2 0.7 3.2 0.5 4.6 1.9 6 15 18 165 -3 0 -2.8 -3 01/19/2006 17:10:00 2.9 0.4 3.8 1.5 2 0.6 3.4 0.7 3.2 0.4 4.2 2.3 3 10 358 165 -3 0 -2.8 -3 01/19/2006 17:20:00 4.1 0.4 4.9 3 2.9 1 5.3 1.5 4.3 0.4 5.3 3.4 358 8 1 165 -3 0 -2.8 -3 01/19/2006 17:30:00 3.2 0.5 4.6 2.3 2.2 0.7 4.6 1.1 3.4 0.5 4.9 2.3 1 8 346 165 -3 0 -2.8 -3 01/19/2006 17:40:00 2.8 0.3 3.8 2.3 1.7 0.5 3.4 0.7 3 0.3 3.8 2.3 3 5 2 165 -3 0 -3 -3.3 01/19/2006 17:50:00 2.8 0.3 3.8 1.9 1.8 0.6 3.4 0.7 2.9 0.3 3.8 1.9 358 7 1 165 -3 0 -3 -3 01/19/2006 18:00:00 3.3 0.4 4.6 2.3 2.9 0.7 4.6 1.1 3.4 0.4 4.6 2.3 348 6 336 165 -3 0 -2.8 -3 01/19/2006 18:10:00 4 0.4 5.3 3 3.7 0.8 5.3 1.5 4.1 0.4 5.7 2.6 347 5 346 165 -3 0 -3 -3.3 01/19/2006 18:20:00 3.9 0.5 4.9 2.6 3.9 0.7 5.3 1.9 4 0.5 5.3 3 345 5 348 165 -3.1 0 -3 -3.3 01/19/2006 18:30:00 2.8 0.3 3.4 1.9 2.2 0.6 3.8 1.1 2.9 0.3 3.4 1.9 359 12 342 165 -3.2 0 -3 -3.3 01/19/2006 18:40:00 2.9 0.3 3.8 2.3 1.8 0.4 3.4 0.7 3.1 0.3 3.8 2.6 7 3 11 165 -3.2 0 -3 -3.3 01/19/2006 18:50:00 2.4 0.3 3 1.9 1.6 0.6 3 0.4 2.5 0.3 3 1.9 2 9 3 165 -3.1 0 -3 -3.3 01/19/2006 19:00:00 3 0.4 3.8 2.3 2.8 0.5 3.8 1.1 3.3 0.4 4.2 2.6 20 7 26 165 -3.1 0 -3 -3.3 01/19/2006 19:10:00 3.1 0.4 3.8 2.3 2.9 0.6 4.2 1.1 3.5 0.4 4.6 2.6 21 7 26 165 -3.2 0 -3 -3.3 01/19/2006 19:20:00 3.4 0.4 4.2 2.6 3.4 0.5 4.2 2.3 3.9 0.3 4.6 3 28 7 31 165 -3.2 0 -3 -3.3 01/19/2006 19:30:00 2.9 0.4 3.8 2.3 3 0.4 4.2 2.3 3.2 0.4 4.2 2.3 34 4 31 165 -3.2 0 -3 -3.3 01/19/2006 19:40:00 3.3 0.5 4.2 2.3 3.4 0.5 4.6 2.3 3.7 0.4 4.6 2.6 33 2 32 165 -3.3 0 -3.3 -3.5 01/19/2006 19:50:00 4.6 0.8 6.1 3.4 4.7 0.8 6.5 3.4 4.7 0.7 6.1 3 30 4 32 165 -3.3 0 -3.3 -3.5 01/19/2006 20:00:00 5.3 0.5 6.1 3.8 5.3 0.5 6.1 4.2 5.4 0.5 6.1 4.2 32 3 31 165 -3.3 0 -3.3 -3.5 01/19/2006 20:10:00 4.1 0.5 5.3 2.6 4.1 0.5 5.3 2.6 4.1 0.5 5.3 2.6 28 7 37 165 -3.3 0 -3.3 -3.5 01/19/2006 20:20:00 4.2 0.5 5.7 2.6 4.2 0.5 5.3 2.3 4.2 0.5 5.7 3 27 6 28 165 -3.4 0 -3.3 -3.5 01/19/2006 20:30:00 4.4 0.5 5.3 3 4.4 0.6 5.3 2.6 4.5 0.6 5.3 2.6 28 4 27 165 -3.4 0 -3.3 -3.5 01/19/2006 20:40:00 4 0.5 5.3 2.6 3.9 0.6 4.9 1.9 4 0.5 5.3 2.6 25 7 24 165 -3.5 0 -3.3 -3.5 01/19/2006 20:50:00 4.6 0.4 5.7 3.4 4.5 0.4 5.3 3 4.7 0.5 5.7 3.4 24 4 22 165 -3.5 0 -3.3 -3.5 01/19/2006 21:00:00 5 0.4 6.1 3.4 4.8 0.5 6.1 3 5.1 0.5 6.1 3.8 24 4 25 165 -3.6 0 -3.5 -3.5 01/19/2006 21:10:00 4.8 0.4 5.7 3.4 4.6 0.4 5.7 3 4.9 0.5 6.1 3.4 23 4 18 165 -3.7 0 -3.5 -3.9 01/19/2006 21:20:00 4.4 0.3 4.9 3.8 4.2 0.4 4.9 3 4.3 0.4 5.3 3 24 4 27 165 -3.8 0 -3.5 -3.9 01/19/2006 21:30:00 4.3 0.4 5.3 3.4 4.1 0.5 5.3 3 4.4 0.5 5.7 3.4 24 5 28 165 -3.8 0 -3.7 -3.9 01/19/2006 21:40:00 4.8 0.3 5.3 3.8 4.6 0.4 5.3 3.4 4.8 0.4 5.7 3.4 27 3 29 165 -3.9 0 -3.7 -3.9 01/19/2006 21:50:00 5.1 0.3 5.7 4.2 5 0.3 5.7 3.8 5.2 0.3 6.1 4.2 31 3 34 165 -4 0 -3.9 -4.2 01/19/2006 22:00:00 4.3 0.4 5.3 3.4 4.2 0.4 5.3 3.4 4.4 0.4 5.7 3 29 3 31 165 -4 0 -3.9 -4.2 01/19/2006 22:10:00 3.6 0.5 4.6 2.3 3.6 0.5 4.6 2.3 3.8 0.5 4.9 1.9 32 3 31 165 -3.9 0 -3.9 -4.2 01/19/2006 22:20:00 3.2 0.6 4.6 2.3 3.1 0.6 4.6 1.9 3.3 0.7 4.6 1.9 32 8 32 165 -3.9 0 -3.9 -3.9 01/19/2006 22:30:00 3.3 0.6 4.6 1.5 3.1 0.7 4.6 0.7 3.2 0.7 4.9 1.1 26 10 31 165 -3.9 0 -3.9 -3.9 01/19/2006 22:40:00 3.9 0.3 4.9 3.4 3.9 0.3 4.9 3 4 0.3 4.9 3 34 3 33 165 -3.9 0 -3.9 -3.9 01/19/2006 22:50:00 3.7 0.4 4.6 2.6 3.7 0.5 4.6 2.6 3.8 0.5 4.9 2.3 39 4 39 165 -3.9 0 -3.9 -3.9 01/19/2006 23:00:00 3.4 0.4 4.6 2.3 3.3 0.4 4.2 2.3 3.4 0.4 4.6 2.3 31 6 31 165 -3.9 0 -3.7 -3.9 01/19/2006 23:10:00 3.8 0.4 4.6 3 3.7 0.4 4.9 2.6 3.9 0.4 4.9 2.6 32 6 26 165 -3.9 0 -3.7 -3.9 01/19/2006 23:20:00 3.2 0.3 4.2 2.6 3.1 0.4 3.8 2.3 3.2 0.4 4.2 1.9 27 4 31 165 -3.9 0 -3.7 -3.9 01/19/2006 23:30:00 2.8 0.3 3.4 2.3 2.6 0.3 3.4 1.9 2.8 0.4 3.8 1.9 27 3 25 165 -3.9 0 -3.7 -3.9 01/19/2006 23:40:00 2.6 0.3 3 1.5 2.5 0.3 3 1.5 2.5 0.3 3 1.1 32 4 32 165 -3.9 0 -3.9 -3.9 01/19/2006 23:50:00 2 0.3 2.6 1.1 1.7 0.4 2.6 0.7 2 0.4 2.6 0.7 19 9 25 165 -3.9 0 -3.7 -3.9 01/20/2006 00:00:00 1.5 0.3 2.3 1.1 1.3 0.4 2.3 0.4 1.5 0.4 2.6 0.4 24 7 31 165 -3.9 0 -3.7 -3.9 01/20/2006 00:10:00 1.9 0.4 2.6 1.1 1.8 0.5 2.6 0.7 2 0.4 3 1.1 37 9 40 165 -3.9 0 -3.7 -3.9 01/20/2006 00:20:00 2.3 0.3 3 1.5 2.1 0.4 3.4 0.7 2.3 0.4 3 1.1 31 8 25 165 -3.9 0 -3.9 -3.9 01/20/2006 00:30:00 2 0.2 2.6 1.5 1.7 0.3 2.3 0.4 1.9 0.3 2.6 1.1 27 7 31 165 -3.9 0 -3.7 -3.9 01/20/2006 00:40:00 2 0.4 2.6 0.7 1.8 0.4 2.6 0.4 2 0.4 2.6 0.7 34 8 42 165 -3.9 0 -3.7 -3.9 01/20/2006 00:50:00 2.2 0.3 3 1.1 2 0.4 3 1.1 2.1 0.4 3 1.1 37 7 31 165 -3.9 0 -3.7 -3.9 01/20/2006 01:00:00 2.4 0.3 3 1.9 2.3 0.3 3 1.5 2.5 0.3 3 1.9 32 5 29 165 -4 0 -3.9 -4.2 01/20/2006 01:10:00 2.5 0.2 3 1.9 2.3 0.3 3 1.5 2.5 0.3 3 1.9 25 4 28 165 -4 0 -3.9 -4.2 01/20/2006 01:20:00 2.8 0.3 3.4 1.9 2.6 0.4 3.4 1.9 2.8 0.3 3.4 1.9 25 3 26 165 -4 0 -3.9 -4.2 01/20/2006 01:30:00 3 0.3 3.4 2.3 2.9 0.3 3.4 1.9 3 0.3 3.8 2.6 29 2 25 165 -4.2 0 -3.9 -4.2 01/20/2006 01:40:00 3 0.2 3.8 2.6 2.7 0.3 3.4 1.9 3.1 0.3 3.8 2.6 30 2 32 165 -4.2 0 -3.9 -4.2 01/20/2006 01:50:00 3.3 0.2 3.8 2.6 3.1 0.3 3.8 2.3 3.3 0.3 3.8 2.6 30 2 28 165 -4.2 0 -3.9 -4.2 01/20/2006 02:00:00 3.2 0.3 3.8 2.6 3 0.3 3.8 2.3 3.3 0.3 3.8 2.3 31 4 34 165 -4.2 0 -3.9 -4.2 01/20/2006 02:10:00 2.8 0.3 3.4 2.3 2.7 0.3 3.4 1.9 2.9 0.3 3.8 1.9 33 5 25 165 -4.2 0 -3.9 -4.2 01/20/2006 02:20:00 2.7 0.3 3.4 1.9 2.6 0.3 3.4 1.9 2.7 0.3 3.8 1.9 37 4 43 165 -4.2 0 -3.9 -4.2 01/20/2006 02:30:00 2.5 0.4 3.4 1.9 2.4 0.4 3.4 1.5 2.5 0.5 3.4 1.5 34 6 32 165 -4.2 0 -3.9 -4.2 01/20/2006 02:40:00 2.2 0.3 3 1.1 2.1 0.3 3 1.1 2.1 0.4 3.4 1.5 37 6 36 165 -4.2 0 -3.9 -4.2 01/20/2006 02:50:00 2.7 0.3 3.4 1.5 2.6 0.4 3.4 1.5 2.7 0.4 3.8 1.5 35 5 30 165 -4.2 0 -3.9 -4.2 01/20/2006 03:00:00 2.6 0.2 3.4 1.9 2.4 0.3 3 1.5 2.7 0.3 3.4 1.9 32 4 32 165 -4.2 0 -3.9 -4.2 01/20/2006 03:10:00 2.5 0.2 3 1.9 2.4 0.3 3 1.5 2.4 0.5 3.8 1.5 42 4 39 165 -4.2 0 -3.9 -4.2 01/20/2006 03:20:00 2.6 0.2 3.4 1.9 2.5 0.3 3.4 1.9 2.2 0.4 3.4 1.5 45 3 48 165 -4.1 0 -3.9 -4.2 01/20/2006 03:30:00 2.6 0.3 3.4 1.5 2.5 0.3 3 1.5 2.5 0.4 3.8 1.5 41 5 44 165 -4.2 0 -3.9 -4.2 01/20/2006 03:40:00 2.9 0.2 3.4 2.3 2.8 0.2 3.4 2.3 2.4 0.5 3.8 1.5 44 3 42 165 -4.2 0 -3.9 -4.2 01/20/2006 03:50:00 3 0.3 3.8 2.3 2.9 0.3 3.4 1.9 2.9 0.4 3.8 1.5 41 4 42 165 -4.2 0 -4.2 -4.2 01/20/2006 04:00:00 2.9 0.3 3.8 1.9 2.6 0.3 3.4 1.5 2.9 0.4 3.8 1.5 34 5 34 165 -4.2 0 -3.9 -4.4 01/20/2006 04:10:00 2.9 0.3 3.8 2.3 2.6 0.3 3.4 1.5 2.9 0.3 3.8 2.3 33 3 29 165 -4.2 0 -3.9 -4.2 01/20/2006 04:20:00 3.1 0.3 3.8 2.6 2.7 0.4 3.4 1.9 3.1 0.3 3.8 2.3 31 3 37 165 -4.1 0 -3.9 -4.2 01/20/2006 04:30:00 3.1 0.4 4.2 2.3 2.7 0.4 4.2 1.9 3.1 0.4 4.2 2.3 31 4 37 165 -4.1 0 -3.9 -4.2 01/20/2006 04:40:00 3.1 0.4 4.2 2.3 2.6 0.5 3.8 0.7 3 0.4 4.2 1.9 30 5 32 165 -4 0 -3.9 -4.2 01/20/2006 04:50:00 3.2 0.2 3.8 2.6 2.7 0.3 3.4 1.9 3.1 0.2 3.8 2.6 29 3 32 165 -4 0 -3.9 -4.2 01/20/2006 05:00:00 3.1 0.3 3.8 2.3 2.6 0.4 3.4 1.5 3 0.3 3.8 2.3 29 3 31 165 -3.9 0 -3.7 -4.2 01/20/2006 05:10:00 2.8 0.3 3.4 2.3 2.4 0.3 3 1.5 2.7 0.3 3.4 1.5 32 3 32 165 -3.9 0 -3.7 -3.9 01/20/2006 05:20:00 2.9 0.2 3.4 1.9 2.5 0.2 3 1.9 2.7 0.2 3.4 1.9 27 2 25 165 -3.9 0 -3.7 -3.9 01/20/2006 05:30:00 3.2 0.2 3.8 2.6 2.8 0.2 3.4 2.3 3 0.2 3.4 2.6 29 2 28 165 -3.8 0 -3.7 -3.9 01/20/2006 05:40:00 3.5 0.2 3.8 3 3 0.2 3.4 2.3 3.3 0.2 3.8 2.3 29 2 29 165 -3.8 0 -3.5 -3.9 01/20/2006 05:50:00 3.4 0.2 3.8 3 3 0.2 3.4 2.6 3.2 0.2 3.8 2.6 30 2 31 165 -3.7 0 -3.5 -3.7 01/20/2006 06:00:00 3.3 0.2 3.8 2.6 2.9 0.2 3.4 2.3 3 0.2 3.4 2.3 30 2 32 165 -3.6 0 -3.5 -3.7 01/20/2006 06:10:00 2.9 0.2 3.4 2.3 2.6 0.3 3.4 1.9 2.7 0.2 3.4 1.9 30 2 34 165 -3.6 0 -3.5 -3.7 01/20/2006 06:20:00 2.7 0.2 3 2.3 2.3 0.2 3 1.9 2.5 0.2 3 1.9 30 2 31 165 -3.5 0 -3.3 -3.5 01/20/2006 06:30:00 2.8 0.2 3.4 2.3 2.4 0.2 3 1.9 2.6 0.2 3 2.3 29 3 25 165 -3.4 0 -3.3 -3.5 01/20/2006 06:40:00 3 0.2 3.4 2.6 2.7 0.2 3.4 1.9 2.9 0.2 3.4 2.3 24 2 23 165 -3.4 0 -3.3 -3.5 01/20/2006 06:50:00 3 0.3 3.4 2.3 2.7 0.3 3.4 1.9 2.9 0.3 3.4 1.9 23 2 25 165 -3.3 0 -3.3 -3.5 01/20/2006 07:00:00 3.2 0.2 3.8 2.3 2.8 0.4 3.4 1.5 3 0.3 3.4 2.3 23 3 18 165 -3.3 0 -3.3 -3.3 01/20/2006 07:10:00 3.1 0.3 3.8 2.3 2.7 0.4 3.4 1.1 3 0.3 3.8 2.3 22 3 22 165 -3.2 0 -3 -3.3 01/20/2006 07:20:00 3.3 0.3 4.2 1.9 2.7 0.5 3.8 0.4 3.1 0.3 3.8 1.9 18 3 16 165 -3.2 0 -3 -3.3 01/20/2006 07:30:00 3.7 0.3 4.6 3 3.2 0.5 4.2 1.5 3.4 0.3 4.2 2.6 19 3 16 165 -3.2 0 -3 -3.3 01/20/2006 07:40:00 4.1 0.3 4.9 3.4 3.5 0.5 4.6 2.3 3.9 0.3 4.9 3 19 3 20 165 -3.2 0 -3 -3.3 01/20/2006 07:50:00 4.2 0.3 4.9 3.4 3.2 0.7 4.6 1.1 3.9 0.4 4.9 2.6 17 3 15 165 -3.1 0 -3 -3.3 01/20/2006 08:00:00 4.4 0.3 5.3 3.8 3.5 0.7 4.6 1.1 4.2 0.4 4.9 3.4 17 3 17 165 -3 0 -2.8 -3.3 01/20/2006 08:10:00 4.7 0.4 5.7 3.4 3.9 0.7 5.3 1.5 4.5 0.4 5.3 3.8 18 3 21 165 -3 0 -2.8 -3 01/20/2006 08:20:00 4.7 0.4 5.7 3.4 3.9 0.7 5.3 1.5 4.4 0.5 5.7 3 18 3 16 165 -2.8 0 -2.8 -3 01/20/2006 08:30:00 4.9 0.4 5.7 3.8 3.8 0.8 5.3 0.7 4.6 0.5 5.3 3.4 17 4 16 165 -2.8 0 -2.6 -2.8 01/20/2006 08:40:00 4.6 0.4 5.7 3.4 3.5 0.7 5.3 0.7 4.3 0.4 5.7 3.4 17 4 16 165 -2.6 0 -2.6 -2.8 01/20/2006 08:50:00 4.6 0.4 5.7 3.8 3.7 0.7 4.9 1.1 4.4 0.4 4.9 3.4 19 4 17 165 -2.6 0 -2.6 -2.8 01/20/2006 09:00:00 4.4 0.4 5.3 3.4 3.4 0.9 4.9 0.4 4.3 0.4 5.3 3.4 18 5 12 165 -2.5 0 -2.6 -2.6 01/20/2006 09:10:00 4.6 0.4 6.1 3.4 3.2 0.8 4.9 0.7 4.4 0.4 5.3 3 16 4 15 165 -2.5 0 -2.6 -2.6 01/20/2006 09:20:00 4.7 0.4 5.7 3.8 3.8 0.7 4.9 1.9 4.6 0.4 5.7 3.4 19 3 15 165 -2.6 0 -2.6 -2.8 01/20/2006 09:30:00 4.9 0.4 6.1 3.8 3.8 0.8 5.3 0.7 4.7 0.5 5.7 3.4 17 5 14 165 -2.6 0 -2.6 -2.8 01/20/2006 09:40:00 4.8 0.4 5.7 3.4 3.6 0.8 4.9 1.1 4.7 0.4 5.7 3.4 18 4 21 165 -2.6 0 -2.6 -2.8 01/20/2006 09:50:00 5.1 0.5 6.1 3.4 4 0.8 5.3 1.1 4.9 0.5 5.7 3 17 4 19 165 -2.6 0 -2.6 -2.8 01/20/2006 10:00:00 5.1 0.6 6.5 3.8 3.6 1.2 5.7 0.7 4.9 0.6 6.1 3 15 5 18 165 -2.5 0 -2.6 -2.6 01/20/2006 10:10:00 5.2 0.5 6.5 3.4 3.4 1.3 5.7 0.7 5 0.5 6.1 3.4 14 5 13 165 -2.5 0 -2.6 -2.6 01/20/2006 10:20:00 4.9 0.4 6.5 3.8 2.3 1.1 5.3 0.4 4.6 0.4 5.7 3.8 11 5 14 165 -2.5 0 -2.6 -2.6 01/20/2006 10:30:00 4.9 0.5 6.5 3.8 2.6 1.2 5.3 0.4 4.9 0.5 6.5 3.4 11 5 11 165 -2.5 0 -2.6 -2.6 01/20/2006 10:40:00 4.4 0.5 5.3 3 2.4 1.1 4.9 0.4 4.4 0.4 5.7 3.4 9 7 19 165 -2.5 0 -2.6 -2.6 01/20/2006 10:50:00 3.6 0.4 4.9 2.6 1.8 0.7 3.8 0.4 3.7 0.4 4.6 2.3 358 5 12 165 -2.5 0 -2.6 -2.8 01/20/2006 11:00:00 3.8 0.4 4.9 2.6 2.4 1 4.6 0.4 3.8 0.4 4.9 3 356 8 1 165 -2.6 0 -2.6 -2.8 01/20/2006 11:10:00 3.8 0.4 5.3 2.6 3.1 1 5.3 0.7 3.7 0.5 4.9 2.3 352 6 7 165 -2.6 0 -2.6 -2.8 01/20/2006 11:20:00 3.5 0.4 4.6 2.6 2.6 0.9 4.6 0.4 3.5 0.4 4.6 2.3 352 5 3 165 -2.6 0 -2.6 -2.8 01/20/2006 11:30:00 3.5 0.6 5.3 2.3 2.4 1.1 4.6 0.4 3.5 0.5 5.3 2.3 353 9 7 165 -2.5 0 -2.4 -2.6 01/20/2006 11:40:00 3.6 0.4 4.9 2.3 3.1 1.1 5.3 0.4 3.6 0.5 4.9 2.6 350 8 358 165 -2.4 0 -2.1 -2.6 01/20/2006 11:50:00 3.7 0.5 5.3 2.6 3.2 1 5.3 0.7 3.8 0.5 5.3 2.3 350 12 6 165 -2.5 0 -2.4 -2.6 01/20/2006 12:00:00 3.8 0.5 5.3 3 3.7 0.7 4.9 1.5 3.9 0.5 4.9 2.6 348 6 0 165 -2.5 0 -2.4 -2.6 01/20/2006 12:10:00 4.3 0.4 5.3 3 2.6 1.1 6.8 0.4 4.3 0.4 5.7 3.4 356 7 359 165 -2.5 0 -2.4 -2.6 01/20/2006 12:20:00 4.4 0.5 5.7 3 3 1.3 5.7 0.7 4.5 0.6 6.1 3.4 354 7 359 165 -2.5 0 -2.4 -2.6 01/20/2006 12:30:00 4.3 0.5 5.7 2.3 3 1.2 6.1 0.7 4.5 0.5 6.1 3 355 8 3 165 -2.5 0 -2.4 -2.6 01/20/2006 12:40:00 4 0.5 5.3 2.6 2.9 1.3 5.7 0.7 4.1 0.5 5.3 2.6 353 9 349 165 -2.2 0 -2.1 -2.6 01/20/2006 12:50:00 4.2 0.6 6.1 3 3 1.1 6.5 1.1 4.4 0.5 6.1 3.4 354 6 343 165 -2.1 0 -1.9 -2.1 01/20/2006 13:00:00 4.4 0.5 6.1 2.6 3.2 1.2 5.7 0.7 4.6 0.6 6.1 3.4 354 7 13 165 -2.1 0 -1.9 -2.1 01/20/2006 13:10:00 4.3 0.4 5.7 3 3.2 1.1 5.7 0.7 4.5 0.4 5.7 3.4 354 7 8 165 -2.1 0 -1.9 -2.1 01/20/2006 13:20:00 4.2 0.6 5.7 3 3.3 1.5 6.1 0.4 4.3 0.6 6.1 3 352 8 0 165 -2.1 0 -1.9 -2.1 01/20/2006 13:30:00 4.1 0.4 5.3 3 3.4 1.1 6.1 0.7 4.2 0.4 5.3 3.4 350 7 349 165 -2.1 0 -1.9 -2.1 01/20/2006 13:40:00 4.4 0.4 6.1 3 4.5 0.7 6.1 1.5 4.5 0.5 6.5 3.4 342 7 358 165 -2.2 0 -2.1 -2.4 01/20/2006 13:50:00 4.8 0.5 6.1 3.4 5.1 0.6 6.8 4.2 4.9 0.5 6.5 3.8 340 7 344 165 -2.2 0 -2.1 -2.4 01/20/2006 14:00:00 5.4 0.7 7.6 3.8 5.5 0.8 7.6 2.6 5.6 0.7 7.6 3.8 341 7 347 165 -2.3 0 -2.1 -2.6 01/20/2006 14:10:00 5.4 0.5 7.2 4.2 5.6 0.6 7.2 3.8 5.5 0.6 6.5 4.2 341 7 349 165 -2.4 0 -2.1 -2.6 01/20/2006 14:20:00 5.1 0.8 6.8 3 5 1 6.8 1.9 5.2 0.8 7.2 3.4 338 9 337 165 -2.3 0 -2.1 -2.6 01/20/2006 14:30:00 5 0.5 6.5 3.8 4.7 1 6.8 1.5 5.1 0.5 6.1 3.8 343 10 338 165 -2.2 0 -2.1 -2.4 01/20/2006 14:40:00 4.2 0.5 5.7 3 3.7 1 5.7 0.7 4.4 0.5 6.1 3.4 343 12 331 165 -2.2 0 -2.1 -2.4 01/20/2006 14:50:00 5.1 0.6 6.8 3.4 4.8 1.1 7.2 1.5 5.3 0.6 6.8 3.4 344 8 339 165 -2.3 0 -2.1 -2.6 01/20/2006 15:00:00 5.6 0.5 6.8 3.8 5.4 0.7 6.8 2.3 5.8 0.5 7.2 4.2 344 7 351 165 -2.4 0 -2.1 -2.6 01/20/2006 15:10:00 5.8 0.5 6.8 4.6 5.8 0.6 6.8 3 5.9 0.5 7.6 4.6 338 8 339 165 -2.3 0 -2.1 -2.6 01/20/2006 15:20:00 6 0.6 7.6 4.2 6 0.6 8 4.2 6 0.7 8.4 4.2 336 7 339 165 -2.1 0 -1.9 -2.1 01/20/2006 15:30:00 6.2 0.7 8 4.6 5.9 1.1 8.8 1.9 6.5 0.9 9.1 3.8 344 8 348 165 -2.1 0 -1.9 -2.1 01/20/2006 15:40:00 5.9 0.9 8.8 3.4 5.2 1.6 8.8 1.1 6.2 0.9 9.1 4.2 348 9 354 165 -2 0 -1.9 -2.1 01/20/2006 15:50:00 6.3 0.6 7.6 4.2 5.2 1.5 7.6 1.5 6.7 0.8 8.4 4.6 350 11 339 165 -1.8 0 -1.7 -1.9 01/20/2006 16:00:00 6 0.7 8 4.2 5.3 1.3 8 2.3 6.6 0.8 9.1 4.9 347 9 349 165 -1.8 0 -1.7 -1.9 01/20/2006 16:10:00 6.4 0.7 9.1 4.9 5.3 1.3 8.4 1.9 6.9 0.7 9.5 5.3 348 9 351 165 -1.9 0 -1.7 -1.9 01/20/2006 16:20:00 6.4 0.7 8.4 4.6 5.9 0.8 8 3.4 7 0.8 9.5 4.9 336 12 336 165 -1.8 0 -1.7 -1.9 01/20/2006 16:30:00 6.8 0.9 9.5 4.2 6.4 1 9.5 3.4 7.2 0.9 10.7 5.3 334 10 339 165 -1.7 0 -1.4 -1.9 01/20/2006 16:40:00 7.7 1 9.9 4.9 7.3 1 9.5 4.6 8.2 1 11.1 5.7 343 9 352 165 -1.6 0 -1.4 -1.7 01/20/2006 16:50:00 7.9 0.9 9.9 6.1 7.7 1 9.9 5.3 8.2 1 10.7 6.1 339 10 353 165 -1.6 0 -1.4 -1.7 01/20/2006 17:00:00 7.5 0.8 9.5 4.9 7.4 0.8 9.1 4.6 7.6 1.1 9.9 4.6 318 12 340 165 -1.7 0 -1.4 -1.9 01/20/2006 17:10:00 7.2 0.9 9.1 5.3 7 0.9 9.1 5.3 7 1.2 10.3 4.2 318 11 314 165 -1.7 0 -1.4 -1.9 01/20/2006 17:20:00 7.2 0.9 10.7 5.3 7.1 0.9 10.3 5.3 7.3 1 9.9 4.6 319 10 334 165 -2.1 0.1 -1.4 -2.4 01/20/2006 17:30:00 7.1 0.6 8.4 5.3 7 0.6 8.4 5.3 7.2 0.6 8.8 5.7 327 12 343 165 -2.4 0 -2.1 -2.6 01/20/2006 17:40:00 7.2 1 9.5 4.9 6.9 1.3 9.9 2.6 7.3 1 9.9 5.3 341 9 345 165 -1.9 0 -1.7 -2.1 01/20/2006 17:50:00 7.2 0.9 9.9 5.3 7.1 0.9 9.5 5.3 7.3 0.9 9.1 4.9 333 9 334 165 -1.5 0 -1.4 -1.7 01/20/2006 18:00:00 6.9 0.7 8.8 5.3 6.9 0.7 8.8 4.9 6.9 0.8 8.8 4.2 324 9 321 165 -1.5 0.1 -1.2 -1.9 01/20/2006 18:10:00 6.5 0.7 8.4 4.9 6.4 0.8 8.4 3.4 6.4 0.7 8.4 4.9 337 12 325 165 -1.8 0 -1.7 -2.1 01/20/2006 18:20:00 5.7 0.6 7.2 4.2 5.6 0.6 7.6 4.2 5.6 0.6 7.2 4.2 328 9 334 165 -1.6 0 -1.4 -1.9 01/20/2006 18:30:00 5.7 0.5 6.8 4.2 5.7 0.5 6.8 4.2 5.5 0.5 6.8 3.8 323 12 341 165 -1.6 0 -1.4 -1.7 01/20/2006 18:40:00 5.3 0.4 6.5 4.2 5.3 0.4 6.1 4.2 4.8 0.6 6.1 3 312 5 319 165 -1.9 0.1 -1.4 -2.1 01/20/2006 18:50:00 4.8 0.4 5.7 3.8 4.8 0.4 5.7 3.8 4.2 0.7 5.3 2.6 310 7 315 165 -1.8 0 -1.4 -1.9 01/20/2006 19:00:00 5.3 0.6 7.2 3.8 5.3 0.6 6.8 3.8 4.4 0.8 7.2 2.6 301 9 289 165 -1.6 0 -1.4 -1.9 01/20/2006 19:10:00 5.2 0.6 6.8 3.8 5.3 0.6 6.8 4.2 4.1 0.8 6.8 2.6 296 5 298 165 -1.8 0.1 -1.4 -2.1 01/20/2006 19:20:00 4.5 0.7 6.1 2.6 4.5 0.8 6.1 2.6 3.5 0.7 5.7 1.9 304 5 301 165 -1.9 0 -1.7 -2.1 01/20/2006 19:30:00 3.7 0.5 4.6 1.9 3.6 0.5 4.6 1.9 3.3 0.4 4.2 2.3 312 6 307 165 -1.6 0.1 -1.4 -1.9 01/20/2006 19:40:00 2.4 0.5 3.8 1.1 2.4 0.5 3.4 1.1 2.5 0.4 3.8 1.1 313 10 319 165 -1.2 0 -1 -1.4 01/20/2006 19:50:00 2.5 0.5 3.8 1.5 2.5 0.5 4.2 1.5 2.9 0.4 3.8 2.3 322 7 310 165 -1.4 0.1 -1.2 -1.7 01/20/2006 20:00:00 1.2 0.8 2.6 0.4 1.2 0.8 2.6 0.4 1.6 1 3 0.4 329 15 321 165 -1.6 0.1 -1.2 -1.9 01/20/2006 20:10:00 0.4 0.2 1.5 0.4 0.4 0.2 1.5 0.4 0.6 0.4 1.9 0.4 212 51 148 165 -1.1 0.1 -0.8 -1.4 01/20/2006 20:20:00 1.2 0.8 3 0.4 1.4 1 3.4 0.4 1.6 1 3.4 0.4 252 32 280 165 -1 0.1 -0.8 -1.2 01/20/2006 20:30:00 0.4 0.2 1.1 0.4 0.4 0.2 1.1 0.4 0.4 0.1 1.1 0.4 189 1 187 165 -0.8 0 -0.5 -0.8 01/20/2006 20:40:00 1.6 0.5 2.3 0.4 1.6 0.5 2.6 0.4 1.6 0.6 2.6 0.4 192 8 198 165 -0.6 0 -0.5 -0.8 01/20/2006 20:50:00 2.6 0.4 3.8 1.9 2.6 0.5 3.8 1.9 2.6 0.6 4.2 1.5 183 8 192 165 -0.8 0.1 -0.5 -1 01/20/2006 21:00:00 2.7 0.5 3.8 1.5 2.8 0.5 3.8 1.5 2.7 0.5 3.8 1.9 188 6 187 165 -1.1 0 -0.8 -1.2 01/20/2006 21:10:00 1.5 0.3 2.3 0.7 1.7 0.3 2.3 0.7 1.7 0.4 2.6 0.7 211 12 199 165 -0.9 0 -0.8 -1.2 01/20/2006 21:20:00 1.4 0.6 2.6 0.4 1.5 0.5 2.6 0.4 1.2 0.6 2.6 0.4 235 11 222 165 -0.8 0 -0.5 -1 01/20/2006 21:30:00 0.7 0.5 2.3 0.4 0.7 0.5 2.6 0.4 0.8 0.6 2.3 0.4 238 10 222 165 -0.5 0 -0.3 -0.8 01/20/2006 21:40:00 1.4 0.4 2.3 0.7 1.3 0.5 2.3 0.4 1.4 0.3 2.3 0.7 200 12 201 165 -0.5 0 -0.3 -0.8 01/20/2006 21:50:00 0.9 0.3 1.9 0.4 0.7 0.3 1.5 0.4 0.7 0.4 1.5 0.4 168 12 181 165 -0.9 0 -0.5 -1 01/20/2006 22:00:00 1.6 0.3 2.3 0.7 1.6 0.4 2.6 0.4 1.8 0.4 3 0.4 142 12 154 165 -1.2 0.2 -0.8 -1.4 01/20/2006 22:10:00 2.4 0.4 3.4 1.9 2.4 0.4 3.4 1.5 2.5 0.4 3.8 1.9 136 11 151 165 -1.7 0.1 -1.4 -1.9 01/20/2006 22:20:00 3.9 0.4 4.6 3 3.6 0.3 4.2 3 3.8 0.4 4.6 3 157 6 158 165 -2 0 -1.7 -1.9 01/20/2006 22:30:00 3.6 0.3 4.6 3 3.4 0.3 4.2 3 3.2 0.4 3.8 2.6 167 4 165 165 -1.8 0 -1.4 -1.9 01/20/2006 22:40:00 2.8 0.5 4.6 1.5 2.7 0.5 4.2 1.5 2.6 0.5 4.2 1.5 168 5 170 165 -1.6 0 -1.4 -1.7 01/20/2006 22:50:00 3.3 0.5 4.6 2.3 3.2 0.4 4.6 2.3 3 0.4 4.2 2.3 170 6 179 165 -1.5 0 -1.4 -1.7 01/20/2006 23:00:00 4 0.6 5.3 2.6 3.8 0.5 4.9 2.6 3.8 0.5 4.9 2.6 168 6 169 165 -1.4 0 -1.4 -1.4 01/20/2006 23:10:00 4 0.6 4.9 2.6 3.7 0.5 4.6 2.3 3.6 0.6 4.6 1.9 169 11 173 165 -1.4 0 -1.2 -1.4 01/20/2006 23:20:00 4.1 0.5 5.3 3 4 0.4 4.9 3 4 0.4 4.9 3 165 3 164 165 -1.3 0 -1 -1.4 01/20/2006 23:30:00 3.5 0.4 4.6 2.6 3.4 0.3 4.2 2.6 3.5 0.3 4.2 2.6 167 16 164 165 -1.2 0 -1 -1.2 01/20/2006 23:40:00 2.7 0.5 4.2 1.5 2.7 0.5 3.8 1.5 2.7 0.4 3.8 1.9 166 6 162 165 -1 0 -0.8 -1.2 01/20/2006 23:50:00 4.1 0.7 5.7 2.3 3.9 0.6 5.3 2.3 3.9 0.7 5.3 1.9 172 8 180 165 -0.9 0 -0.8 -1.2 01/21/2006 00:00:00 3.6 0.5 4.6 2.3 3.4 0.5 4.6 1.9 3.6 0.4 4.6 2.6 166 7 164 165 -0.9 0 -0.8 -1.2 01/21/2006 00:10:00 2.1 0.8 4.2 0.4 1.9 0.9 4.2 0.4 2.2 0.6 3.8 0.7 157 11 151 165 -1 0 -0.8 -1.2 01/21/2006 00:20:00 2.5 0.5 4.2 1.1 2.5 0.6 3.8 0.7 2.6 0.5 4.2 1.5 145 12 155 165 -1 0 -0.8 -1.2 01/21/2006 00:30:00 3 0.6 4.6 1.1 2.9 0.6 4.2 0.7 2.9 0.5 4.2 1.9 156 9 160 165 -0.9 0 -0.8 -1 01/21/2006 00:40:00 3.1 1 4.6 1.1 3.1 0.9 4.6 1.1 3 0.8 4.6 1.1 156 9 164 165 -0.8 0 -0.5 -1 01/21/2006 00:50:00 4.2 0.8 6.1 2.6 4.1 0.7 6.1 2.6 3.9 0.7 6.1 3 158 4 155 165 -0.6 0 -0.5 -0.8 01/21/2006 01:00:00 5.3 0.4 6.1 4.2 5.2 0.4 6.1 3.8 5.1 0.5 6.1 3.8 157 3 156 165 -0.2 0 -0.1 -0.5 01/21/2006 01:10:00 4.9 0.5 6.1 3.4 4.9 0.5 5.7 3.4 4.9 0.5 6.1 3.8 154 10 156 165 0 0 0.2 -0.1 01/21/2006 01:20:00 4.4 0.5 5.3 3 4.4 0.5 5.3 3 4.4 0.4 5.3 3 156 3 153 165 0.2 0 0.2 0.2 01/21/2006 01:30:00 3.5 0.6 4.9 1.9 3.5 0.6 4.9 1.9 3.5 0.5 4.9 2.3 156 0 157 165 0.2 0 0.4 0.2 01/21/2006 01:40:00 2.8 0.8 4.6 1.5 2.8 0.8 4.6 1.5 2.8 0.8 4.6 1.5 156 0 157 165 0.4 0 0.7 0.2 01/21/2006 01:50:00 2.8 0.3 3.4 1.9 3 0.4 3.8 2.3 2.7 0.4 3.4 1.9 156 0 157 165 0.4 0 0.7 0.2 01/21/2006 02:00:00 2.5 0.3 3 1.9 2.7 0.3 3.4 2.3 2.5 0.4 3.4 1.5 156 0 157 165 0.7 0 0.9 0.7 01/21/2006 02:10:00 2 0.3 2.6 1.1 2.1 0.3 3 1.1 2 0.4 3 1.1 156 0 157 165 0.8 0 0.9 0.7 01/21/2006 02:20:00 2.2 0.7 4.2 0.7 2.3 0.7 4.2 0.7 2.3 0.8 4.9 0.4 156 0 157 165 0.9 0.1 1.4 0.9 01/21/2006 02:30:00 2.9 0.6 4.6 1.5 2.9 0.7 4.9 1.1 2.9 0.8 6.5 1.5 156 0 157 165 1.4 0 1.4 1.4 01/21/2006 02:40:00 2.8 0.6 4.9 1.5 2.8 0.6 4.6 1.5 2.7 0.5 4.2 1.5 156 0 157 165 1.3 0 1.6 1.4 01/21/2006 02:50:00 3.3 0.6 5.3 1.9 3.2 0.6 5.3 1.9 3.2 0.5 4.9 2.3 156 0 157 165 1.1 0 1.4 1.1 01/21/2006 03:00:00 3.9 0.6 5.3 1.9 3.8 0.6 5.3 1.9 3.9 0.6 5.3 2.3 156 0 157 165 0.9 0 1.4 0.9 01/21/2006 03:10:00 3.6 0.5 4.6 2.3 3.5 0.4 4.6 2.6 3.4 0.4 4.6 2.3 156 0 157 165 0.8 0 0.9 0.9 01/21/2006 03:20:00 3.6 0.7 5.7 2.3 3.6 0.6 5.3 2.3 3.6 0.6 5.3 2.6 156 0 157 165 0.8 0 0.9 0.7 01/21/2006 03:30:00 4.5 0.7 6.5 2.6 4.4 0.6 6.1 2.6 4.5 0.6 6.1 3.4 156 0 157 165 0.7 0 0.9 0.7 01/21/2006 03:40:00 4.7 0.8 6.8 2.6 4.6 0.8 6.5 2.3 4.6 0.7 6.5 2.6 156 0 157 165 0.7 0 0.9 0.7 01/21/2006 03:50:00 5.4 0.6 6.8 4.2 5.3 0.5 6.8 3.8 5.2 0.6 7.2 4.2 156 0 157 165 0.7 0 0.9 0.7 01/21/2006 04:00:00 5.2 0.8 7.2 3.4 5.1 0.8 7.2 3.4 5.2 0.7 7.2 3.8 156 0 157 165 0.6 0 0.9 0.7 01/21/2006 04:10:00 5.4 0.9 7.2 3 5.3 0.9 6.8 3 5.3 0.8 7.2 3 156 0 157 165 0.8 0 0.9 0.7 01/21/2006 04:20:00 4.9 0.8 6.5 3 4.7 0.8 6.5 3 4.9 0.7 6.8 3 156 0 157 165 0.8 0 0.9 0.7 01/21/2006 04:30:00 4 0.8 5.7 1.9 3.9 0.8 5.7 1.9 4.1 0.7 6.1 2.6 156 0 157 165 0.8 0 0.9 0.7 01/21/2006 04:40:00 3.8 0.8 5.7 1.9 3.7 0.8 5.3 1.9 3.8 0.8 5.7 2.3 156 0 157 165 0.7 0 0.9 0.7 01/21/2006 04:50:00 3.3 0.7 5.7 1.9 3.2 0.7 5.3 1.9 3.2 0.6 4.9 1.9 156 0 157 165 0.7 0 0.9 0.7 01/21/2006 05:00:00 4 0.6 5.7 2.6 3.9 0.6 5.3 2.6 4 0.5 5.3 2.6 156 0 157 165 0.6 0 0.9 0.7 01/21/2006 05:10:00 4.3 0.6 5.7 2.6 4.1 0.5 5.3 3 4.3 0.5 5.7 3 156 0 157 165 0.8 0.1 0.9 0.7 01/21/2006 05:20:00 3.9 0.6 5.7 2.3 3.8 0.6 5.3 2.3 3.6 0.5 4.9 2.3 156 0 157 165 0.9 0 1.1 0.9 01/21/2006 05:30:00 3.8 0.6 5.3 2.6 3.7 0.6 4.9 2.3 3.9 0.6 5.7 2.6 156 0 157 165 1 0 1.4 0.9 01/21/2006 05:40:00 3.2 0.4 4.6 2.3 3 0.4 4.2 1.9 3.3 0.4 4.6 2.3 156 0 157 165 1 0 1.4 0.9 01/21/2006 05:50:00 2.7 0.8 4.6 0.7 1.5 1.4 4.6 0.4 2.6 0.8 4.6 1.1 156 0 157 165 0.9 0 1.4 0.9 01/21/2006 06:00:00 2.3 0.3 3 1.5 0.4 0 0.4 0.4 2.3 0.3 3 1.5 156 0 157 165 0.9 0 1.1 0.9 01/21/2006 06:10:00 2.2 0.2 2.6 1.5 0.4 0 0.4 0.4 2.2 0.2 3 1.9 156 0 157 165 0.9 0 1.1 0.9 01/21/2006 06:20:00 1.6 0.6 3 0.4 0.4 0 0.4 0.4 1.7 0.5 3 0.4 156 0 157 165 0.9 0 1.4 0.9 01/21/2006 06:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 2.3 0.5 3.8 1.1 156 0 165 165 1 0 1.1 0.9 01/21/2006 06:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 2.5 0.5 4.2 1.5 156 0 165 165 1 0 1.4 0.9 01/21/2006 06:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 2.8 0.6 4.6 1.5 156 0 165 165 1.2 0 1.4 1.1 01/21/2006 07:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 2.3 0.4 3.4 1.1 156 0 165 165 1.2 0 1.4 1.1 01/21/2006 07:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 2 0.7 3.4 0.4 156 0 165 165 1.2 0 1.4 1.1 01/21/2006 07:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 2.5 0.4 3.8 1.5 156 0 165 165 1.2 0 1.4 1.1 01/21/2006 07:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 2.2 0.4 3.4 1.1 156 0 165 165 1.2 0 1.4 1.1 01/21/2006 07:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 2.3 0.4 3 1.1 156 0 165 165 1.2 0 1.4 1.1 01/21/2006 07:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 3 0.4 4.2 2.3 156 0 165 165 1.2 0 1.4 1.1 01/21/2006 08:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 2.3 0.5 3.8 1.1 156 0 165 165 1.3 0 1.4 1.1 01/21/2006 08:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 2.4 0.4 3.4 1.5 156 0 165 165 1.4 0 1.6 1.4 01/21/2006 08:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 1 0.8 2.6 0.4 156 0 165 165 1.4 0 1.6 1.4 01/21/2006 08:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 156 0 165 165 1.5 0 1.6 1.4 01/21/2006 08:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 156 0 165 165 1.5 0 1.8 1.4 01/21/2006 08:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 156 0 165 165 1.6 0 1.6 1.6 01/21/2006 09:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 156 0 165 165 1.6 0 1.8 1.6 01/21/2006 09:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 156 0 165 165 1.7 0 1.8 1.6 01/21/2006 09:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 156 0 165 165 1.7 0 1.8 1.6 01/21/2006 09:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 156 0 165 165 1.8 0 1.8 1.6 01/21/2006 09:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 156 0 165 165 1.8 0 1.8 1.8 01/21/2006 09:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 156 0 165 165 1.8 0 1.8 1.8 01/21/2006 10:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 156 0 165 165 1.9 0 1.8 1.8 01/21/2006 10:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 156 0 165 165 1.9 0 1.8 1.8 01/21/2006 10:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 156 0 165 165 1.9 0 1.8 1.8 01/21/2006 10:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 156 0 165 165 1.9 0 2.1 1.8 01/21/2006 10:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 156 0 165 165 2 0 2.1 1.8 01/21/2006 10:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 156 0 165 165 2.1 0 2.3 1.8 01/21/2006 11:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.7 0.4 156 0 165 165 2.3 0 2.3 2.1 01/21/2006 11:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 155 0 165 165 2.3 0 2.6 2.3 01/21/2006 11:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 155 0 165 165 2.3 0 2.6 2.3 01/21/2006 11:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 155 0 165 165 2.4 0 2.6 2.3 01/21/2006 11:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 156 0 165 165 2.4 0 2.6 2.3 01/21/2006 11:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 156 0 165 165 2.4 0 2.6 2.3 01/21/2006 12:00:00 0.4 0.1 1.1 0.4 0.4 0 0.4 0.4 0.6 0.3 1.5 0.4 159 1 159 165 2.4 0 2.6 2.3 01/21/2006 12:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.7 0.4 161 2 165 165 2.8 0.1 3 2.6 01/21/2006 12:20:00 0.4 0.1 0.7 0.4 0.4 0 0.4 0.4 0.4 0.1 0.7 0.4 306 6 304 165 3 0 3.3 2.8 01/21/2006 12:30:00 0.4 0.1 0.7 0.4 0.4 0 0.4 0.4 0.4 0.1 0.7 0.4 304 0 304 165 2.7 0.1 3 2.6 01/21/2006 12:40:00 0.6 0.4 1.5 0.4 0.4 0.2 1.5 0.4 0.6 0.3 1.5 0.4 303 0 304 165 2.6 0 2.8 2.6 01/21/2006 12:50:00 1.4 0.3 1.9 0.7 1.3 0.3 1.9 0.7 1.4 0.2 1.9 0.7 312 3 310 165 2.7 0 2.8 2.6 01/21/2006 13:00:00 1.1 0.2 1.9 0.7 0.9 0.2 1.5 0.4 0.8 0.3 1.5 0.4 310 6 302 165 2.6 0.1 2.8 2.6 01/21/2006 13:10:00 1.3 0.3 1.9 0.7 1.2 0.3 1.9 0.7 0.9 0.5 2.3 0.4 295 5 299 165 2.5 0 2.6 2.6 01/21/2006 13:20:00 1.8 0.4 2.6 1.1 1.7 0.4 2.6 1.1 1.5 0.4 2.6 0.4 295 4 292 165 2.4 0 2.6 2.3 01/21/2006 13:30:00 1.8 0.4 2.6 1.1 1.7 0.4 2.6 1.1 1.7 0.5 2.6 0.4 287 5 282 165 2.3 0 2.6 2.3 01/21/2006 13:40:00 2.5 0.3 3 1.5 2.6 0.3 3.4 1.5 2.6 0.3 3.4 1.5 277 6 279 165 2.4 0 2.6 2.3 01/21/2006 13:50:00 2.3 0.5 3.4 1.5 2.8 0.5 3.8 1.9 3.1 0.4 4.2 2.3 268 3 267 165 2.3 0 2.6 2.3 01/21/2006 14:00:00 2.7 0.4 3.8 1.5 3.5 0.4 4.2 2.6 3.8 0.3 4.6 3 260 4 252 165 2.1 0 2.3 1.8 01/21/2006 14:10:00 3.3 0.6 4.9 1.9 4.5 0.6 6.1 3 4.5 0.5 5.7 3 263 3 266 165 1.9 0 2.1 1.8 01/21/2006 14:20:00 3.8 0.5 4.9 2.3 5.1 0.4 6.1 4.2 5 0.4 6.1 3.8 262 4 264 165 1.9 0 1.8 1.8 01/21/2006 14:30:00 3.8 0.7 5.7 1.9 4.8 0.6 5.7 3 4.8 0.6 5.7 3 266 6 274 165 1.8 0 1.8 1.8 01/21/2006 14:40:00 2.7 0.7 4.6 0.7 3 0.6 4.2 1.5 2.8 0.6 4.2 1.1 249 7 245 165 1.9 0 2.1 1.8 01/21/2006 14:50:00 2.6 0.6 4.2 1.1 2.5 0.6 4.2 1.1 2.3 0.6 3.8 1.1 233 11 231 165 2.1 0.1 2.6 1.8 01/21/2006 15:00:00 3.2 0.6 4.2 1.9 3.2 0.6 4.6 1.5 3.3 0.6 4.6 1.9 205 8 210 165 2.9 0.2 3.5 2.3 01/21/2006 15:10:00 2.3 0.6 3.4 0.7 2.1 0.7 3.4 0.4 2.3 0.7 3.8 0.4 191 11 198 165 3.4 0 3.5 3.3 01/21/2006 15:20:00 2.3 0.6 3.8 0.7 2.2 0.6 3.4 0.7 2.2 0.8 3.8 0.4 216 19 199 165 3.1 0.1 3.5 2.8 01/21/2006 15:30:00 2.2 0.5 3 0.7 2.2 0.4 3 1.5 2.1 0.4 3 1.1 246 8 238 165 2.8 0.3 3.3 2.3 01/21/2006 15:40:00 2.9 0.6 4.2 1.5 2.8 0.6 4.2 1.1 2.8 0.7 4.6 1.5 226 8 225 165 2.2 0 2.3 2.1 01/21/2006 15:50:00 2.9 0.5 3.8 1.9 2.8 0.5 3.8 1.5 2.9 0.5 3.8 1.9 230 5 231 165 2.1 0 2.3 2.1 01/21/2006 16:00:00 2.6 0.5 4.2 1.5 2.6 0.5 4.2 1.9 2.6 0.4 3.8 1.5 240 6 248 165 2.1 0 2.3 1.8 01/21/2006 16:10:00 6.6 3.6 14.1 1.9 7 3.2 14.5 3.4 5.9 2.3 11.8 3 280 17 298 165 1.8 0.1 2.3 1.4 01/21/2006 16:20:00 15 1 17.2 11.5 15 1 17.2 11.5 13.3 1.5 16.4 9.1 297 1 297 165 0.7 0.6 1.6 -0.5 01/21/2006 16:30:00 14.5 1.4 17.6 10.7 14.5 1.4 17.9 10.3 13.1 1.7 17.9 9.5 297 0 297 165 -1 0.3 -0.3 -1.4 01/21/2006 16:40:00 15 1.4 18.3 11.1 14.9 1.4 18.3 10.7 12.9 1.8 18.3 9.1 297 0 297 165 -1.6 0 -1.4 -1.7 01/21/2006 16:50:00 14.7 1.7 18.3 9.5 14.7 1.7 17.9 9.1 12.5 2.1 16.8 6.5 297 0 297 165 -1.6 0 -1.4 -1.7 01/21/2006 17:00:00 11.4 1.2 14.5 8.8 11.3 1.1 14.5 8.4 9.2 1.7 14.1 6.1 298 0 298 165 -1.6 0 -1.4 -1.7 01/21/2006 17:10:00 10 1 13 7.2 9.9 1 12.6 6.8 8 1.2 12.6 5.7 298 0 298 165 -1.7 0 -1.4 -1.7 01/21/2006 17:20:00 7.7 1.1 10.7 5.3 7.7 1.1 10.3 4.9 6.3 1.1 8.8 3.8 298 0 298 165 -1.7 0 -1.4 -1.9 01/21/2006 17:30:00 8 0.9 11.1 4.9 8.1 0.9 11.1 5.7 6.9 1.1 9.9 3.8 298 0 297 165 -1.6 0 -1.4 -1.7 01/21/2006 17:40:00 9.1 1.2 11.5 6.5 9.3 1.2 11.5 6.1 8.8 1.3 11.8 4.9 297 0 297 165 -1.7 0 -1.4 -1.9 01/21/2006 17:50:00 9.7 1.5 13.3 5.3 10.1 1.4 13.3 5.7 9.5 1.6 13.3 4.9 285 12 297 165 -2 0 -1.9 -2.4 01/21/2006 18:00:00 5.6 1.7 12.2 2.3 6.1 1.5 12.2 3.4 5.9 1.4 12.2 3.4 273 0 273 165 -2.6 0 -2.1 -2.8 01/21/2006 18:10:00 7 1.9 11.8 3.4 7.1 1.9 11.5 3.8 6.8 1.8 13 3.4 272 0 272 165 -3 0 -2.8 -3 01/21/2006 18:20:00 10.5 1.9 14.5 6.5 10.7 1.9 14.9 6.1 10.1 1.9 14.9 6.5 258 21 221 165 -3.5 0.2 -3 -3.7 01/21/2006 18:30:00 11.9 1.1 14.5 8.8 12 1.2 14.9 8.8 12.1 1.3 14.9 8.4 218 2 221 165 -3.9 0.1 -3.5 -4.2 01/21/2006 18:40:00 11.4 1.3 14.5 7.6 11.4 1.3 14.5 8 11.7 1.3 14.9 6.8 215 1 215 165 -4.3 0 -4.2 -4.4 01/21/2006 18:50:00 9.6 1.4 13.7 6.1 9.8 1.4 13.3 6.5 9.2 1.3 13.3 6.1 214 0 214 165 -4.7 0.1 -4.4 -4.8 01/21/2006 19:00:00 9.1 1.7 12.6 5.7 9.3 1.8 13.3 5.7 8.8 1.6 13 5.3 214 0 214 165 -4.9 0 -4.8 -5 01/21/2006 19:10:00 8.9 1.5 12.6 4.9 9.1 1.5 12.6 4.9 8.4 1.6 11.8 4.2 214 0 214 165 -5.2 0.1 -5 -5.5 01/21/2006 19:20:00 7 1.5 11.1 3.8 7.1 1.5 11.1 3.8 6.5 1.4 10.7 3.4 214 0 214 165 -5.5 0 -5.3 -5.7 01/21/2006 19:30:00 7 1.9 11.5 3.8 7.2 2 11.5 3.8 6.8 2 11.8 3.8 214 0 214 165 -5.8 0 -5.5 -5.7 01/21/2006 19:40:00 6.1 1.7 9.9 2.3 6.4 1.5 9.9 2.6 5.8 1.4 9.5 3 214 0 214 165 -6 0 -5.7 -6.4 01/21/2006 19:50:00 7.3 1.2 10.7 3.4 7.5 1.2 11.1 4.6 7.2 1.2 10.3 4.2 214 0 214 165 -6.4 0 -6.1 -6.6 01/21/2006 20:00:00 6.3 2 11.8 3 6.5 2 11.5 2.6 6.2 1.9 11.5 2.3 214 0 214 165 -6.6 0 -6.4 -6.8 01/21/2006 20:10:00 6.4 1.3 9.5 3.4 6.7 1 9.1 4.2 6.4 1 8.8 4.2 214 0 214 165 -6.8 0.1 -6.6 -6.8 01/21/2006 20:20:00 6.4 1.9 10.7 3 6.7 1.8 11.1 3.4 6.3 1.7 10.7 3 214 0 214 165 -7.1 0 -6.8 -7.4 01/21/2006 20:30:00 7.7 1.3 10.7 4.6 7.8 1.3 11.1 4.9 7.5 1.3 11.1 4.9 214 0 214 165 -7.4 0 -7.2 -7.4 01/21/2006 20:40:00 7.9 1.3 11.1 4.6 8.1 1.3 11.5 4.6 7.7 1.4 11.1 4.6 214 0 214 165 -7.5 0 -7.2 -7.6 01/21/2006 20:50:00 6 1.7 9.9 1.9 6.2 1.6 10.3 3 5.7 1.5 9.1 1.9 214 0 215 165 -7.6 0 -7.4 -7.9 01/21/2006 21:00:00 5.9 1.9 9.9 1.5 6.6 2.3 11.8 2.3 6.4 2.2 11.8 2.3 214 0 215 165 -8 0.1 -7.6 -8.1 01/21/2006 21:10:00 8.8 2.3 15.6 3.8 9.8 2.1 16.1 4.6 9.4 2.2 16.1 4.6 228 18 253 165 -8.1 0 -7.6 -8.3 01/21/2006 21:20:00 8.8 2.3 14.9 3.8 9 1.9 14.1 4.2 8.6 1.8 14.1 4.9 252 0 252 165 -8.2 0.2 -7.6 -8.5 01/21/2006 21:30:00 10.9 2.5 17.2 5.7 11.1 2.5 17.2 5.7 10.6 2.6 16.8 5.3 238 10 252 165 -8.5 0 -8.3 -8.7 01/21/2006 21:40:00 10.1 2.6 16.4 4.9 10.3 2.6 16.8 5.3 9.6 2.6 16.4 4.9 226 7 220 165 -8.8 0.1 -8.5 -9.1 01/21/2006 21:50:00 7.1 2.3 13 2.6 7.4 2.1 11.8 3.4 6.8 2.1 11.8 3 234 0 234 165 -9.1 0.1 -8.9 -9.3 01/21/2006 22:00:00 6.8 2.1 17.2 3.4 7.4 2.3 17.9 4.2 7 2.3 17.2 3.8 253 18 270 165 -9.4 0 -9.3 -9.7 01/21/2006 22:10:00 8.7 2.4 14.1 4.2 9.4 2.3 15.3 4.6 8.9 2.2 13.3 4.9 259 11 249 165 -9.5 0 -9.3 -9.7 01/21/2006 22:20:00 8.4 2 14.5 4.6 9.8 2.3 16.4 5.3 9.5 2.4 16.8 4.6 259 8 255 165 -9.4 0 -9.3 -9.7 01/21/2006 22:30:00 7.1 1.6 13 4.2 7.8 1.6 12.6 4.2 7.3 1.7 12.2 4.2 250 13 250 165 -9.5 0 -9.3 -9.7 01/21/2006 22:40:00 8.3 1.3 12.6 4.6 8.5 1.2 13 5.7 8 1.3 12.2 4.9 238 16 217 165 -9.5 0 -9.3 -9.7 01/21/2006 22:50:00 6.4 2.4 14.9 2.6 6.5 2.4 15.3 2.6 6.3 2.3 13 2.3 228 17 230 165 -9.6 0 -9.3 -9.7 01/21/2006 23:00:00 7.1 1.4 11.5 3.8 7.1 1.4 11.5 4.2 6.6 1.3 10.3 3.8 213 17 234 165 -9.6 0 -9.3 -9.7 01/21/2006 23:10:00 9.4 1.7 13.7 4.9 9.5 1.8 13.7 4.9 9.4 1.9 14.1 5.3 203 11 212 165 -9.7 0 -9.5 -9.7 01/21/2006 23:20:00 8.2 1.5 13.3 5.3 8.2 1.5 13.3 5.3 8 1.3 11.8 5.3 198 12 206 165 -9.8 0 -9.7 -10 01/21/2006 23:30:00 9.5 2 14.5 5.3 9.7 2.1 14.9 5.3 9.3 2.2 14.5 5.3 210 11 220 165 -9.7 0 -9.5 -10.2 01/21/2006 23:40:00 10.3 2 15.6 5.3 10.4 2 16.1 5.7 10.2 1.9 14.9 6.5 210 13 219 165 -9.8 0 -9.7 -10 01/21/2006 23:50:00 7.8 1.9 13.3 4.2 7.9 2 13.3 4.6 7.5 2 13 4.2 222 15 219 165 -10 0.1 -9.7 -10.2 01/22/2006 00:00:00 6.9 1.2 10.7 3.8 7 1.2 10.7 4.2 6.7 1.3 11.5 4.2 213 13 225 165 -10.1 0.1 -9.7 -10.4 01/22/2006 00:10:00 7.2 1.1 9.9 4.6 7.3 1.1 9.9 4.6 7 1.2 10.3 4.2 212 11 235 165 -10.3 0 -10.2 -10.6 01/22/2006 00:20:00 6.8 1.5 11.5 3.8 6.9 1.5 11.5 3.8 6.7 1.5 11.1 3.4 209 9 217 165 -10.5 0 -10.4 -10.8 01/22/2006 00:30:00 6.1 1.5 9.9 2.3 6.2 1.4 9.9 1.9 5.8 1.3 8.8 1.9 229 22 218 165 -10.5 0 -10.4 -10.6 01/22/2006 00:40:00 1.6 1.1 6.1 0.4 1.7 1.1 5.7 0.4 1.3 1 4.9 0.4 293 51 283 165 -10.8 0.1 -10.6 -11 01/22/2006 00:50:00 1.4 0.8 3.4 0.4 1.5 0.9 3.4 0.4 1.3 0.7 3 0.4 288 38 288 165 -11 0 -10.8 -11.2 01/22/2006 01:00:00 2.9 0.8 4.6 0.4 3 0.7 4.6 1.5 2.7 0.7 4.9 0.4 262 30 243 165 -10.9 0.1 -10.6 -11.4 01/22/2006 01:10:00 2.4 0.5 3.8 1.5 2.1 0.7 3.8 0.7 2.6 0.5 3.8 1.5 4 16 323 165 -11.5 0.2 -11 -11.8 01/22/2006 01:20:00 2.2 0.7 4.2 0.4 2.1 0.8 4.9 0.4 2.2 0.7 3.4 0.4 342 47 286 165 -11.4 0.1 -11 -11.8 01/22/2006 01:30:00 2 0.6 3.4 0.4 2.1 0.6 3.8 0.7 1.6 0.6 3.8 0.4 292 14 290 165 -11 0.1 -10.8 -11.2 01/22/2006 01:40:00 2.3 0.3 3 1.5 2.3 0.3 3 1.5 2.2 0.3 2.6 1.5 320 15 326 165 -11.3 0.1 -10.8 -11.6 01/22/2006 01:50:00 6 2.1 9.5 2.3 6 2.1 9.5 2.6 4.7 1.6 7.6 1.5 297 8 298 165 -11.3 0 -11 -11.6 01/22/2006 02:00:00 7.9 0.8 10.3 6.1 7.9 0.8 10.3 6.1 6.6 1 9.5 4.2 305 7 304 165 -11.7 0.1 -11.4 -12 01/22/2006 02:10:00 7.5 1 9.9 5.3 7.4 1 10.3 4.9 6.3 1.1 8.8 3.4 305 10 310 165 -11.9 0 -11.6 -12.2 01/22/2006 02:20:00 5.6 1.3 9.5 3 5.5 1.3 9.5 3.4 4.3 1.1 7.6 1.9 301 8 295 165 -11.9 0 -11.8 -12.2 01/22/2006 02:30:00 3.3 0.7 5.3 1.5 3.7 0.7 5.3 1.9 3.5 0.7 4.9 1.9 268 18 287 165 -12 0.1 -11.6 -12.2 01/22/2006 02:40:00 2.4 0.6 3.8 0.7 2.6 0.5 3.8 1.1 2.6 0.5 3.8 1.1 245 15 247 165 -11.7 0 -11.6 -11.8 01/22/2006 02:50:00 3.7 0.7 5.7 1.5 4.1 0.7 5.7 2.3 3.9 0.8 5.7 1.5 253 7 250 165 -11.7 0 -11.6 -11.8 01/22/2006 03:00:00 2.8 0.8 4.6 0.7 3.1 1 4.9 0.7 2.9 0.9 4.9 1.1 240 23 256 165 -11.9 0 -11.8 -12 01/22/2006 03:10:00 2.2 1.2 5.3 0.4 2.5 1.2 5.3 0.4 2.1 1.1 5.3 0.4 258 19 305 165 -11.9 0 -11.8 -12 01/22/2006 03:20:00 3.5 1.5 7.6 0.7 3.8 1.5 8.4 1.1 3.2 1.2 6.8 1.1 271 27 309 165 -11.9 0 -11.8 -12 01/22/2006 03:30:00 6.6 1.8 11.1 2.6 7 1.7 11.5 3.4 6.4 1.9 11.1 2.3 278 12 277 165 -11.9 0 -11.8 -12.2 01/22/2006 03:40:00 10.2 1.6 14.1 6.1 10.2 1.5 14.5 7.2 8.8 1.6 13 4.2 288 10 279 165 -11.8 0 -11.8 -11.8 01/22/2006 03:50:00 9.3 1.7 13.3 4.9 9.6 1.7 13.7 5.3 8.8 1.9 13 4.2 281 9 274 165 -11.9 0 -11.8 -12 01/22/2006 04:00:00 9.9 1.9 14.1 4.9 10 1.9 14.1 5.3 8.9 2.1 14.5 3.8 286 8 275 165 -12 0 -11.8 -12.2 01/22/2006 04:10:00 11.6 1.3 16.8 8 11.8 1.3 17.2 8.4 10.9 1.5 15.3 7.6 283 9 286 165 -11.9 0 -11.8 -12.2 01/22/2006 04:20:00 13.3 1.7 17.2 9.5 13.4 1.7 17.6 9.5 12.1 2.4 17.2 6.8 287 7 282 165 -12.2 0 -12 -12.4 01/22/2006 04:30:00 14.6 1.7 18.3 10.7 14.6 1.7 18.7 10.3 12.8 2.4 19.9 8 288 6 284 165 -12.3 0 -12.2 -12.4 01/22/2006 04:40:00 15.6 1.7 20.2 11.5 15.7 1.7 21 11.1 13.6 2.7 20.2 8.4 290 7 282 165 -12.4 0 -12.2 -12.6 01/22/2006 04:50:00 13.9 2 17.6 7.6 14 2 17.6 7.2 11.9 2.6 17.2 6.5 290 7 292 165 -12.4 0 -12.2 -12.6 01/22/2006 05:00:00 13.2 2.1 17.6 7.2 13.2 2.2 17.6 6.8 11.9 2.6 18.3 5.3 291 8 287 165 -12.4 0 -12.2 -12.6 01/22/2006 05:10:00 14.2 1.9 18.7 9.1 14.2 1.8 19.1 9.1 12.1 2.3 17.9 7.2 292 9 285 165 -12.6 0 -12.4 -12.6 01/22/2006 05:20:00 14 2.3 18.7 6.8 14 2.3 18.7 6.5 12 2.6 18.7 6.5 294 9 292 165 -12.5 0 -12.4 -12.6 01/22/2006 05:30:00 13.5 1.7 17.9 8 13.5 1.7 17.9 8.4 11.5 2.4 19.9 6.8 292 8 285 165 -12.7 0 -12.6 -12.8 01/22/2006 05:40:00 14.9 1.8 19.5 10.7 14.8 1.9 19.5 10.7 11.6 1.7 16.4 7.2 295 7 292 165 -13 0.1 -12.6 -13.2 01/22/2006 05:50:00 15.3 2 20.6 8.8 15.3 2.1 20.2 8.8 12.4 2.3 19.5 8 293 7 290 165 -13.1 0 -13 -13.2 01/22/2006 06:00:00 16.7 1.7 20.2 11.1 16.8 1.7 20.6 11.1 14.1 2.4 20.6 8.8 291 7 282 165 -13.2 0 -13.2 -13.4 01/22/2006 06:10:00 16.5 1.9 21 11.1 16.5 1.9 20.6 11.1 13.3 2.1 19.9 9.1 294 7 292 165 -13.3 0 -13.2 -13.6 01/22/2006 06:20:00 13 1.7 18.3 8.4 13 1.8 17.9 7.6 11.1 2.4 19.1 6.1 294 10 284 165 -13.3 0 -13.2 -13.4 01/22/2006 06:30:00 12.9 1.5 16.8 9.1 12.9 1.6 16.8 8.8 11.2 2.2 16.4 6.5 288 6 290 165 -13.2 0 -13.2 -13.4 01/22/2006 06:40:00 12.5 1.7 16.1 8 12.5 1.7 16.4 7.6 10.9 1.9 16.8 6.1 287 8 284 165 -13.3 0 -13.2 -13.4 01/22/2006 06:50:00 10.6 2.1 15.6 5.7 10.7 2.1 16.1 5.3 9.4 2.3 15.6 4.6 290 9 281 165 -13.5 0.1 -13.2 -13.6 01/22/2006 07:00:00 10.3 1.5 13.7 6.1 10.3 1.5 13.7 6.5 8.8 1.7 13.7 4.6 290 8 291 165 -13.5 0 -13.4 -13.6 01/22/2006 07:10:00 9.2 1.2 11.8 5.3 9.2 1.3 11.8 5.3 7.7 1.5 11.5 4.6 293 9 284 165 -13.5 0 -13.4 -13.6 01/22/2006 07:20:00 8.7 1.6 13 4.6 8.8 1.5 13 5.3 8.1 1.5 11.8 4.6 283 8 287 165 -13.5 0 -13.4 -13.6 01/22/2006 07:30:00 5 1 8 2.6 5.3 1 7.6 2.3 4.8 1 7.6 2.6 279 12 293 165 -13.4 0 -13.2 -13.6 01/22/2006 07:40:00 6.9 1.8 11.5 2.3 7 1.7 11.5 3.4 6.4 1.6 9.9 3 284 9 282 165 -13.4 0 -13.2 -13.6 01/22/2006 07:50:00 7.9 1.7 12.6 3.8 8 1.7 12.6 4.6 7.3 1.7 12.6 3.8 282 8 282 165 -13.3 0 -13.2 -13.4 01/22/2006 08:00:00 10.4 1.7 14.9 6.5 10.4 1.7 14.9 6.5 9 1.9 15.3 4.6 290 10 279 165 -13.4 0 -13.2 -13.6 01/22/2006 08:10:00 11.5 1.7 16.4 7.2 11.4 1.7 16.8 7.2 9.3 1.6 14.5 4.9 294 9 296 165 -13.2 0 -13 -13.4 01/22/2006 08:20:00 10.1 2.1 14.1 4.6 10.1 2.1 14.9 4.6 8.5 1.8 14.5 3.4 293 8 289 165 -13.1 0 -13 -13.2 01/22/2006 08:30:00 9.4 1.5 13 5.3 9.5 1.5 13 5.3 8.2 1.5 11.8 4.6 288 9 294 165 -13.1 0 -13 -13.2 01/22/2006 08:40:00 10.7 2.2 16.8 4.9 10.7 2.3 17.6 4.9 9.6 2.5 16.1 3.8 288 9 274 165 -13.3 0.1 -13.2 -13.6 01/22/2006 08:50:00 12.7 2.1 17.2 8.4 12.7 2.1 17.2 8 10.4 2.1 16.4 6.1 295 9 293 165 -13.6 0 -13.4 -13.8 01/22/2006 09:00:00 12.6 1.6 16.4 6.8 12.6 1.6 16.4 7.2 10.6 2 16.8 6.1 293 9 300 165 -13.7 0 -13.6 -13.8 01/22/2006 09:10:00 11.5 2.2 17.2 7.2 11.5 2.2 16.8 6.8 9.5 2 16.1 5.3 294 9 297 165 -13.7 0 -13.6 -13.8 01/22/2006 09:20:00 12.1 1.7 15.6 6.8 12.1 1.7 15.6 8 10.4 1.8 15.3 6.1 289 7 286 165 -13.8 0 -13.6 -14 01/22/2006 09:30:00 10.6 1.5 14.1 6.5 10.6 1.6 14.1 6.8 9.3 1.7 13.7 4.6 289 8 296 165 -13.9 0 -13.8 -14 01/22/2006 09:40:00 11.3 1.4 14.9 7.6 11.3 1.5 15.3 6.8 9.9 1.8 15.6 6.1 290 8 284 165 -13.8 0 -13.6 -14 01/22/2006 09:50:00 11.4 2.1 16.8 6.8 11.5 2.2 16.8 6.5 10.6 2.7 16.8 4.9 288 9 284 165 -13.9 0 -13.6 -14 01/22/2006 10:00:00 11.9 1.7 16.8 8 12.1 1.6 16.8 8.4 11 1.8 16.8 6.8 284 9 277 165 -14 0 -13.8 -14 01/22/2006 10:10:00 10.6 2.5 16.1 4.6 10.9 2.3 16.4 5.3 10.2 2.4 16.1 5.3 281 9 292 165 -13.9 0 -13.8 -14 01/22/2006 10:20:00 10.4 1.7 15.3 6.1 10.8 1.5 15.3 6.5 10 1.7 14.1 5.7 282 10 293 165 -14 0 -13.8 -14 01/22/2006 10:30:00 7.8 1.9 12.2 3.8 7.9 1.8 12.6 4.2 7 1.8 13 3.8 285 10 282 165 -14 0 -13.8 -14 01/22/2006 10:40:00 12 1.9 16.1 7.6 12.1 1.8 16.8 8 10.6 2 15.6 5.7 287 10 286 165 -14 0 -14 -14 01/22/2006 10:50:00 12.5 1.8 16.8 7.2 12.5 1.8 16.8 7.6 11.3 2.4 17.6 5.7 285 6 279 165 -14 0 -13.8 -14 01/22/2006 11:00:00 10.9 1.7 15.6 7.6 11 1.7 15.6 7.6 10.1 2 15.6 6.1 285 7 286 165 -14.1 0 -14 -14 01/22/2006 11:10:00 10.5 1.6 14.1 4.6 10.5 1.7 14.5 4.9 9 1.9 14.9 4.9 294 12 277 165 -14.1 0 -14 -14 01/22/2006 11:20:00 11 1.8 15.3 6.5 11 1.8 15.3 6.5 9.5 2.1 14.9 4.6 290 9 293 165 -14 0 -13.8 -14 01/22/2006 11:30:00 10.6 1.5 14.5 6.1 10.6 1.5 14.9 6.1 9.1 1.7 14.1 3 289 10 287 165 -13.8 0 -13.8 -14 01/22/2006 11:40:00 12.6 2.3 16.8 7.6 12.6 2.3 17.2 7.6 10.5 2.3 16.1 6.5 294 10 299 165 -14 0.1 -13.8 -14 01/22/2006 11:50:00 11.9 1.9 15.6 6.8 11.9 2 16.4 6.8 10.6 2.6 17.2 4.9 290 7 288 165 -14.1 0 -14 -14.2 01/22/2006 12:00:00 9 1.7 12.6 4.9 9.1 1.7 13 5.3 8.3 2 13 4.2 295 15 286 165 -14.1 0.1 -13.8 -14.4 01/22/2006 12:10:00 9.6 1.9 14.5 5.7 9.7 2 14.9 5.3 8.4 2.1 13.7 4.6 294 13 290 165 -13.9 0.1 -13.8 -14 01/22/2006 12:20:00 12.7 2.4 17.6 4.9 12.8 2.4 17.9 5.3 11.4 2.7 17.9 5.7 290 9 287 165 -14.1 0 -14 -14.2 01/22/2006 12:30:00 13.4 3.1 19.9 6.8 13.7 2.9 20.2 7.2 12.6 2.9 20.2 5.7 282 10 292 165 -14 0 -13.8 -14.2 01/22/2006 12:40:00 12.8 2.6 18.7 4.2 12.9 2.6 19.1 4.9 11.5 2.8 18.3 4.9 285 9 291 165 -14.1 0 -14 -14.2 01/22/2006 12:50:00 12.9 2.4 17.9 7.6 13 2.5 17.9 6.8 11.6 2.9 18.7 6.5 287 10 281 165 -14.1 0.1 -14 -14.2 01/22/2006 13:00:00 12.8 2.4 18.7 6.8 12.7 2.4 18.3 8.4 11.3 2.8 21.4 4.6 303 10 308 165 -13.8 0 -13.6 -14 01/22/2006 13:10:00 14.7 1.6 19.1 11.1 14.7 1.7 18.7 11.1 12.8 2.4 18.3 8.8 293 11 291 165 -13.7 0 -13.6 -14 01/22/2006 13:20:00 16.2 1.5 20.6 11.8 16.3 1.6 20.6 11.8 15.2 2.2 20.2 9.1 284 7 289 165 -13.7 0 -13.6 -14 01/22/2006 13:30:00 16.7 1.6 21.4 13 16.6 1.6 21.8 13 14.4 2.2 19.5 9.1 305 8 297 165 -13.1 0.2 -12.6 -13.6 01/22/2006 13:40:00 16.1 2.1 22.1 11.5 16 2.1 21.8 10.7 13.9 2.4 21.4 8 307 7 306 165 -13 0 -12.8 -13.2 01/22/2006 13:50:00 12.3 1.6 16.1 8 12.4 1.6 16.1 8.4 11.6 2 16.1 6.5 286 12 282 165 -13.1 0.2 -12.6 -13.6 01/22/2006 14:00:00 14.1 1.9 18.3 8.8 14.3 1.8 18.7 8.8 13.6 2 17.9 8.8 279 7 277 165 -13.6 0 -13.4 -13.8 01/22/2006 14:10:00 14.7 2.4 20.6 7.2 14.9 2.4 20.6 8.4 13.9 2.7 19.5 6.5 283 9 287 165 -13.7 0 -13.6 -13.8 01/22/2006 14:20:00 11.3 1.8 15.6 7.6 11.3 1.8 15.6 7.6 9.8 2.2 15.6 5.7 291 11 284 165 -13.6 0 -13.4 -13.8 01/22/2006 14:30:00 13.9 2.7 19.5 7.2 13.9 2.8 19.5 7.6 13.1 3.3 19.1 4.6 286 8 290 165 -13.6 0.1 -13.2 -13.8 01/22/2006 14:40:00 13.4 2 17.2 8 13.5 2.1 17.6 8 12.6 2.4 17.6 6.5 285 7 273 165 -13.7 0 -13.6 -14 01/22/2006 14:50:00 14.4 2.5 20.2 7.6 14.4 2.5 20.6 8 13 2.9 21.4 6.8 288 7 282 165 -13.7 0 -13.6 -13.8 01/22/2006 15:00:00 15.3 1.9 20.2 10.7 15.3 1.9 20.2 10.7 14.5 2.5 20.6 8.4 285 6 287 165 -13.8 0 -13.6 -14 01/22/2006 15:10:00 11.8 2 16.8 6.8 11.8 2 16.4 6.5 9.8 2.1 16.1 5.3 293 11 301 165 -13.8 0 -13.6 -14 01/22/2006 15:20:00 10.2 1.9 16.1 5.7 10.1 1.9 16.1 5.3 8.9 1.9 13.7 4.9 298 13 290 165 -13.7 0 -13.6 -14 01/22/2006 15:30:00 13.2 1.8 20.2 8.8 13.3 1.9 20.2 8.4 12.2 2.3 18.7 7.2 286 8 297 165 -14 0.1 -13.6 -14 01/22/2006 15:40:00 14 2.5 20.2 9.5 14.1 2.5 20.2 9.5 12.6 2.8 20.6 6.1 287 9 283 165 -14.1 0 -14 -14.2 01/22/2006 15:50:00 14.5 1.7 18.7 10.7 14.5 1.7 18.7 11.1 12.4 2.4 19.1 7.6 292 8 283 165 -14.2 0 -14 -14.4 01/22/2006 16:00:00 13.1 1.5 17.9 8 13.1 1.6 17.9 8 10.9 1.8 15.6 6.8 296 10 307 165 -14.2 0 -14 -14.4 01/22/2006 16:10:00 12.4 2.3 19.1 7.2 12.4 2.4 19.1 6.8 10.7 2.4 16.8 5.3 296 11 296 165 -14.2 0 -14 -14.4 01/22/2006 16:20:00 11.3 2.5 17.2 6.5 11.3 2.5 16.8 6.5 9.4 2.3 14.5 4.6 294 9 291 165 -14.4 0 -14.2 -14.6 01/22/2006 16:30:00 12.2 2.7 18.7 6.5 12.2 2.6 19.1 6.1 10.9 2.8 19.9 5.3 289 11 280 165 -14.5 0 -14.4 -14.6 01/22/2006 16:40:00 12.9 2.3 19.9 7.2 13 2.3 19.5 7.2 11.6 2.6 19.5 5.3 288 12 308 165 -14.5 0 -14.4 -14.6 01/22/2006 16:50:00 12 1.8 16.8 6.8 12.3 1.7 17.2 8 11.5 2.2 17.2 5.7 281 9 278 165 -14.6 0.1 -14.4 -14.6 01/22/2006 17:00:00 12.7 1.8 17.2 8.4 12.7 1.8 16.8 8.4 10.8 2.1 16.8 6.5 290 8 292 165 -14.6 0 -14.6 -14.8 01/22/2006 17:10:00 12.2 1.5 16.8 8.8 12.2 1.5 16.8 8.8 11.2 2 15.6 6.8 286 8 272 165 -14.6 0 -14.4 -14.6 01/22/2006 17:20:00 10.5 1.6 15.3 6.8 10.5 1.7 15.3 7.2 9.1 2.1 15.3 5.3 296 11 279 165 -14.5 0 -14.4 -14.6 01/22/2006 17:30:00 10.9 1.5 14.1 7.2 10.8 1.5 14.1 7.2 9.5 1.6 14.9 6.1 300 12 318 165 -14.6 0 -14.6 -14.6 01/22/2006 17:40:00 10.9 2 16.4 6.1 11 2 16.4 6.1 9.6 2.1 17.2 5.3 290 12 283 165 -14.7 0 -14.6 -14.8 01/22/2006 17:50:00 13.3 2.4 20.2 6.8 13.4 2.4 20.2 8 11.5 2.6 17.6 4.6 288 10 290 165 -14.6 0 -14.6 -14.8 01/22/2006 18:00:00 14.3 2.6 19.5 8.8 14.3 2.6 19.5 8.8 12.4 2.7 18.7 6.5 290 11 297 165 -14.6 0 -14.6 -14.8 01/22/2006 18:10:00 15.8 2.2 21.4 8.4 15.9 2.2 21 8.4 13.8 2.7 19.9 8 290 10 297 165 -14.7 0 -14.6 -14.8 01/22/2006 18:20:00 15.3 1.8 20.2 11.1 15.4 1.8 19.9 10.3 13.6 2.6 20.6 7.2 289 8 289 165 -14.6 0 -14.4 -14.6 01/22/2006 18:30:00 16 2.1 21.4 11.5 16 2.2 21.4 11.1 14.7 2.5 20.6 8 285 6 278 165 -14.5 0 -14.4 -14.6 01/22/2006 18:40:00 13.7 1.8 18.3 9.1 13.8 1.9 17.9 9.5 12.7 2.6 18.3 6.5 287 8 302 165 -14.4 0 -14.2 -14.6 01/22/2006 18:50:00 12.7 2.1 17.6 8 12.8 2.1 18.3 7.6 11.4 2.6 17.6 5.7 289 9 282 165 -14.3 0 -14.2 -14.6 01/22/2006 19:00:00 13.5 2.2 19.9 7.2 13.5 2.2 19.9 7.2 11.7 2.4 17.9 6.5 293 10 308 165 -14.3 0 -14.2 -14.6 01/22/2006 19:10:00 16.1 1.7 21.4 11.1 16 1.7 21.4 11.1 13.1 1.9 18.3 8.4 294 8 291 165 -14.3 0 -14 -14.4 01/22/2006 19:20:00 17.5 1.8 21.8 13 17.4 1.9 21.8 12.6 14.2 2.1 21.8 9.9 298 7 292 165 -14.2 0 -14 -14.4 01/22/2006 19:30:00 19.5 2.5 24.4 14.5 19.6 2.5 24.8 14.5 16.6 3.2 24.8 10.3 292 6 287 165 -14 0 -13.8 -14 01/22/2006 19:40:00 20.9 2.2 26.8 16.4 21 2.2 26.8 16.4 17.9 2.9 26 11.8 290 6 292 165 -14 0.1 -13.8 -14 01/22/2006 19:50:00 19.4 2.8 26 10.7 19.4 2.8 26 10.3 16.4 3.1 24.4 9.1 292 9 282 165 -14.1 0 -13.8 -14.4 01/22/2006 20:00:00 19.1 1.9 24.4 14.1 19 1.9 24.8 14.5 15.7 2.4 21.8 8.8 294 8 301 165 -14.2 0 -14 -14.6 01/22/2006 20:10:00 18.8 2.3 24 11.8 18.7 2.4 24.4 12.6 16.1 2.8 24.4 9.9 294 9 290 165 -14.1 0.1 -13.8 -14.4 01/22/2006 20:20:00 19.5 2.5 26.3 12.2 19.6 2.5 26.8 12.6 17 2.8 26.8 11.1 290 8 282 165 -14.1 0 -14 -14.2 01/22/2006 20:30:00 16.7 2.2 22.1 9.9 16.7 2.2 21.8 10.7 15 2.9 22.9 9.1 287 9 280 165 -14.2 0 -14 -14.4 01/22/2006 20:40:00 14.6 2.1 20.6 8.8 14.6 2.1 20.2 9.5 13.2 2.4 20.6 8 286 9 289 165 -14.1 0 -14 -14 01/22/2006 20:50:00 12.7 2.9 21 5.7 13.3 2.9 21.8 6.8 12.5 3.2 21.4 6.1 278 9 273 165 -13.8 0 -13.6 -14 01/22/2006 21:00:00 16.5 2 21.8 11.8 16.6 2 21.4 11.8 15.2 2.6 24 8 285 7 294 165 -13.9 0 -13.8 -14 01/22/2006 21:10:00 16.1 1.7 20.6 12.2 16.1 1.7 21 12.2 13.9 2.4 20.6 9.5 288 6 282 165 -14.1 0 -14 -14 01/22/2006 21:20:00 16.5 1.3 20.2 10.7 16.5 1.4 20.6 11.1 13.2 2 18.7 9.1 291 7 300 165 -14.1 0 -14 -14.2 01/22/2006 21:30:00 16.1 1.7 21.4 12.2 16.1 1.8 22.1 11.8 12.4 2.3 22.9 8 295 6 285 165 -14 0 -13.6 -14 01/22/2006 21:40:00 15.7 1.9 20.2 10.3 15.7 2 20.2 10.3 12.9 2.3 20.2 8 292 6 286 165 -13.7 0 -13.6 -13.8 01/22/2006 21:50:00 14.7 2.2 19.9 9.5 14.6 2.3 19.9 9.5 11.8 2.1 17.6 7.2 293 6 291 165 -13.6 0 -13.6 -13.8 01/22/2006 22:00:00 13.3 1.9 17.9 8 13.2 1.9 17.9 8 10.6 1.9 15.3 6.1 296 8 296 165 -13.6 0 -13.4 -13.6 01/22/2006 22:10:00 14.6 2.1 20.2 10.3 14.5 2.2 20.2 9.5 12.2 2.2 18.3 6.8 292 7 284 165 -13.5 0 -13.2 -13.6 01/22/2006 22:20:00 12.6 2.1 17.9 7.6 12.5 2.1 17.9 7.2 10.6 2.3 18.3 5.3 296 9 301 165 -13.5 0 -13.4 -13.6 01/22/2006 22:30:00 12.1 1.6 15.6 8 11.9 1.7 16.1 7.2 9.5 1.6 16.4 5.7 299 9 305 165 -13.6 0 -13.6 -13.6 01/22/2006 22:40:00 12 2.3 17.9 6.5 11.8 2.3 17.6 6.5 9.8 2 16.4 5.3 300 9 291 165 -13.5 0 -13.4 -13.6 01/22/2006 22:50:00 11.2 1.7 16.8 6.8 11.1 1.7 16.8 6.8 9.1 1.5 15.3 6.1 300 8 302 165 -13.6 0 -13.6 -13.8 01/22/2006 23:00:00 14.4 1.4 17.9 10.7 14.3 1.4 18.3 10.3 11.2 1.8 17.2 7.2 298 7 309 165 -13.5 0 -13.4 -13.6 01/22/2006 23:10:00 15.9 1.9 21 10.3 15.8 1.9 20.6 9.9 12 1.5 16.4 8.8 299 6 295 165 -13.3 0 -13.2 -13.6 01/22/2006 23:20:00 14.3 1.8 19.5 9.5 14.1 1.8 19.5 8.8 11 1.7 16.8 7.2 298 7 297 165 -13.4 0 -13.2 -13.6 01/22/2006 23:30:00 16 1.7 21.4 11.1 15.9 1.7 21.4 11.1 12.3 1.6 18.7 8.8 299 6 297 165 -13.4 0 -13.2 -13.6 01/22/2006 23:40:00 15.9 1.3 19.9 12.6 15.8 1.3 19.9 12.2 13.2 1.7 17.6 9.1 304 6 305 165 -13.5 0.1 -13.4 -13.6 01/22/2006 23:50:00 16 1.5 19.5 11.5 15.9 1.5 19.1 11.8 12.7 2 17.6 8.8 303 6 303 165 -13.5 0 -13.4 -13.6 01/23/2006 00:00:00 16.2 1.5 20.2 11.8 16.1 1.6 20.2 11.8 12.7 1.7 17.2 8 302 7 296 165 -13.5 0 -13.2 -13.6 01/23/2006 00:10:00 15.5 1.5 19.9 10.3 15.4 1.6 19.5 9.9 12.5 1.7 18.7 8.4 303 7 295 165 -13.4 0 -13.2 -13.6 01/23/2006 00:20:00 15.8 1.6 21 10.3 15.7 1.7 21.4 11.1 12.2 1.7 16.8 8 297 7 295 165 -13.2 0 -13 -13.4 01/23/2006 00:30:00 15.8 2 20.6 11.8 15.7 2 20.2 11.5 12 1.7 17.6 8.4 300 6 298 165 -13.1 0 -13 -13.4 01/23/2006 00:40:00 17.3 1.3 20.6 13.7 17.3 1.3 20.6 13.7 12.4 1.7 18.3 9.1 298 5 288 165 -13.1 0 -13 -13.2 01/23/2006 00:50:00 16.6 1.3 20.2 11.8 16.5 1.4 19.9 11.8 12.4 1.8 20.6 8.4 299 6 299 165 -13.1 0 -13 -13.2 01/23/2006 01:00:00 16.3 1.5 19.1 11.8 16.2 1.5 19.5 11.8 12.5 1.8 18.3 8.8 299 7 308 165 -13 0 -12.8 -13.2 01/23/2006 01:10:00 15.3 1.5 19.1 11.1 15.2 1.5 19.5 11.1 11.8 1.5 16.4 7.6 298 6 297 165 -13 0 -12.6 -13.2 01/23/2006 01:20:00 14.1 1.2 17.9 11.5 14 1.2 17.6 11.5 10.8 1.5 16.4 7.6 300 7 300 165 -13.1 0 -12.8 -13.2 01/23/2006 01:30:00 15.7 1.5 18.7 10.7 15.6 1.5 18.7 10.3 11.5 1.4 15.6 8 299 5 296 165 -12.9 0.1 -12.6 -13.2 01/23/2006 01:40:00 15.2 1.5 18.7 11.5 15.2 1.5 18.7 11.1 11.5 1.5 16.1 7.2 301 6 300 165 -12.7 0 -12.6 -13 01/23/2006 01:50:00 15.3 1.6 19.5 11.1 15.2 1.6 19.1 11.1 11.7 1.6 16.1 7.6 300 6 297 165 -12.6 0 -12.4 -12.8 01/23/2006 02:00:00 14 1.5 18.3 10.3 13.9 1.6 17.9 10.3 10.9 1.3 14.1 7.6 303 6 294 165 -12.6 0 -12.4 -12.6 01/23/2006 02:10:00 13.3 1.3 16.8 9.9 13.2 1.4 16.8 9.9 10.4 1.3 14.5 7.2 302 6 296 165 -12.5 0 -12.4 -12.6 01/23/2006 02:20:00 12 1.3 14.9 8.8 11.8 1.3 14.5 8.8 9.5 1.2 13.3 6.8 303 6 292 165 -12.6 0 -12.4 -12.6 01/23/2006 02:30:00 10 1.2 13 7.6 9.8 1.1 13 7.6 8.6 1.1 11.8 6.1 310 8 304 165 -12.6 0 -12.4 -12.8 01/23/2006 02:40:00 9.3 1.3 13 6.1 9.2 1.3 13 6.1 8.2 1.4 11.5 5.3 308 7 310 165 -12.6 0 -12.4 -12.6 01/23/2006 02:50:00 9.4 1.4 13.3 6.1 9.2 1.4 13.3 6.1 8 1.3 13.3 5.3 307 9 317 165 -12.6 0.1 -12.2 -12.8 01/23/2006 03:00:00 10.3 1.3 13.3 7.2 10.2 1.2 13.3 7.6 8.8 1.3 12.2 5.7 308 8 305 165 -12.3 0 -12.2 -12.4 01/23/2006 03:10:00 9.7 1.3 13 5.7 9.6 1.3 13.3 5.3 9.1 1.2 12.6 5.7 318 10 317 165 -12.4 0 -12.2 -12.6 01/23/2006 03:20:00 9.6 1.2 13.7 6.5 9.5 1.2 13.3 6.5 8.8 1.3 14.1 5.7 315 9 311 165 -12.4 0 -12.2 -12.4 01/23/2006 03:30:00 9.3 1.2 12.6 6.1 9.2 1.2 12.6 5.7 8.8 1.2 11.1 5.3 320 9 302 165 -12.4 0 -12.2 -12.4 01/23/2006 03:40:00 10.9 1.7 13.7 6.1 10.7 1.7 13.7 6.1 10.6 1.5 14.1 6.5 322 7 323 165 -12.4 0 -12.4 -12.6 01/23/2006 03:50:00 11.2 0.9 13.3 8 11.1 0.9 13 8 10.8 1 13 7.2 321 6 321 165 -12.6 0 -12.4 -12.6 01/23/2006 04:00:00 10.1 1.1 12.6 7.2 9.9 1.1 12.2 6.8 9.8 1.2 12.6 6.5 321 6 327 165 -12.7 0 -12.6 -13 01/23/2006 04:10:00 10 1.1 12.6 6.5 9.8 1.1 12.6 6.5 9.6 1.2 12.2 5.3 317 6 318 165 -12.5 0 -12.4 -12.6 01/23/2006 04:20:00 11.4 1.1 14.9 8 11.2 1.1 14.5 8.4 11 1.2 14.9 8 322 7 322 165 -12.5 0 -12.4 -12.6 01/23/2006 04:30:00 9.9 0.9 11.8 8 9.7 0.9 11.5 7.6 9.4 0.9 11.8 6.8 319 6 324 165 -12.6 0 -12.4 -12.6 01/23/2006 04:40:00 10.1 1.2 12.2 6.1 9.9 1.2 12.2 6.5 9.3 1.3 12.2 5.3 317 6 309 165 -12.5 0.1 -12.2 -12.6 01/23/2006 04:50:00 10.1 1 13 7.2 9.9 1 13 7.6 9.7 0.9 11.8 7.2 319 7 320 165 -12.3 0 -12 -12.4 01/23/2006 05:00:00 12.1 1.2 14.1 7.6 12 1.2 14.1 7.6 11.7 1.1 14.5 8 318 5 317 165 -12.2 0 -12 -12.4 01/23/2006 05:10:00 11.9 0.9 14.1 8.8 11.8 0.9 14.1 8.4 11.5 1 14.1 8.8 320 6 319 165 -12.2 0 -12.2 -12.4 01/23/2006 05:20:00 11.8 1 14.1 8.8 11.6 1 14.1 8.4 11.2 1 14.1 8.4 320 5 318 165 -12.3 0 -12.2 -12.4 01/23/2006 05:30:00 11.2 1.3 13.3 7.6 11.1 1.3 13.3 7.6 10.7 1.5 13.7 6.8 321 5 322 165 -12.3 0 -12.2 -12.4 01/23/2006 05:40:00 9.6 0.8 12.2 6.8 9.4 0.8 11.8 7.2 9 1 12.2 5.7 317 7 301 165 -12.3 0 -12.2 -12.4 01/23/2006 05:50:00 8.4 0.9 10.7 5.7 8.3 0.9 10.3 5.7 7.5 1 10.7 4.9 313 8 332 165 -12.2 0 -12 -12.4 01/23/2006 06:00:00 7.8 0.9 11.1 5.3 7.6 0.9 11.1 5.7 6.9 1 9.5 3.8 314 8 315 165 -12.2 0 -12 -12.4 01/23/2006 06:10:00 9.4 1.1 12.2 6.8 9.2 1.1 12.2 6.5 8.7 1.2 12.2 5.7 318 9 307 165 -12 0 -11.8 -12.2 01/23/2006 06:20:00 7.3 0.9 9.5 4.9 7.1 0.9 9.5 4.6 6.5 0.9 8.4 4.2 313 9 285 165 -11.9 0 -11.8 -11.8 01/23/2006 06:30:00 7.1 0.8 9.5 4.9 7 0.8 9.5 4.9 6.4 0.8 8.8 4.6 313 7 304 165 -11.8 0 -11.6 -11.8 01/23/2006 06:40:00 6.7 0.7 8.8 3.8 6.5 0.7 8.8 3.4 5.5 0.8 8 3.4 308 7 307 165 -11.8 0 -11.6 -11.8 01/23/2006 06:50:00 6.2 0.8 8.8 4.9 6 0.8 8.8 4.2 4.8 0.8 7.6 3.4 302 6 284 165 -11.8 0 -11.6 -11.8 01/23/2006 07:00:00 3.7 0.8 5.7 2.3 3.2 1 5.7 1.5 3.6 0.6 4.9 2.3 357 28 306 165 -11.9 0 -11.6 -12 01/23/2006 07:10:00 3.5 0.4 4.6 2.3 2.7 0.8 4.6 1.1 3.5 0.3 4.2 2.3 354 15 322 165 -12 0 -11.8 -12.2 01/23/2006 07:20:00 3.5 0.5 4.9 2.3 3.1 0.8 4.6 1.1 3.4 0.5 4.9 2.3 341 12 333 165 -12 0 -11.8 -12.2 01/23/2006 07:30:00 2.7 0.6 4.2 1.1 2.3 0.7 4.2 0.7 2.6 0.5 3.8 1.1 337 15 341 165 -11.9 0 -11.8 -12 01/23/2006 07:40:00 4.8 2.4 8.8 0.4 4.5 2.6 8.8 0.4 3.9 1.8 8 0.7 319 30 294 165 -11.7 0.1 -11.4 -12 01/23/2006 07:50:00 8.5 1.4 11.8 5.3 8.4 1.4 11.8 4.9 7.2 1.1 10.3 4.6 308 9 300 165 -11.4 0 -11.4 -11.6 01/23/2006 08:00:00 9.5 1.7 13.3 6.1 9.4 1.7 13.3 6.1 8.4 1.5 12.2 4.9 311 8 307 165 -11.4 0 -11.4 -11.6 01/23/2006 08:10:00 10.5 1.2 13.3 7.2 10.4 1.2 13 7.2 8.5 1.2 12.2 5.3 307 7 296 165 -11.3 0 -11.4 -11.4 01/23/2006 08:20:00 11.5 1.3 14.9 9.1 11.4 1.3 14.9 8.8 10 1.5 13.3 6.1 308 7 304 165 -11.4 0 -11.4 -11.6 01/23/2006 08:30:00 11.8 1.6 15.3 8.4 11.7 1.6 14.9 8 10 1.7 14.5 5.7 310 5 308 165 -11.5 0 -11.4 -11.6 01/23/2006 08:40:00 11.8 1.1 14.5 8.8 11.7 1.1 14.5 8.8 9.4 1.2 12.2 5.7 306 5 309 165 -11.5 0 -11.4 -11.6 01/23/2006 08:50:00 11.4 1.2 14.1 8.4 11.2 1.3 13.7 8 8.9 1.2 13.3 6.5 304 6 294 165 -11.6 0 -11.4 -11.6 01/23/2006 09:00:00 11.5 1.2 15.3 8.4 11.3 1.2 14.9 8 9.1 1.3 13.3 6.1 303 7 295 165 -11.5 0 -11.4 -11.6 01/23/2006 09:10:00 11.9 1.5 14.9 8.4 11.7 1.5 14.5 8 9.4 1.5 14.1 6.1 304 6 299 165 -11.4 0 -11.4 -11.6 01/23/2006 09:20:00 10.8 1.2 13.7 7.6 10.6 1.2 13.3 7.6 8.3 1.3 13 5.7 299 7 301 165 -11.4 0 -11.4 -11.4 01/23/2006 09:30:00 11.2 1.2 16.4 8.4 11 1.2 16.1 8 8.2 1.2 11.5 5.7 300 6 305 165 -11.4 0 -11.2 -11.6 01/23/2006 09:40:00 10.9 1.5 13.7 5.3 10.6 1.5 13.7 5.7 8.8 1.3 11.8 5.3 301 9 294 165 -11.3 0 -11.2 -11.4 01/23/2006 09:50:00 11.6 1.3 14.9 8 11.5 1.3 14.9 7.6 8.9 1.4 13.7 5.3 301 7 299 165 -11.2 0 -11 -11.4 01/23/2006 10:00:00 10.5 1.7 15.3 6.5 10.3 1.7 15.6 6.8 8.2 1.5 13 5.3 304 8 303 165 -11 0 -11 -11.4 01/23/2006 10:10:00 11.7 1.7 15.6 7.6 11.6 1.6 15.6 7.2 9.1 1.4 15.6 5.7 302 6 302 165 -11 0 -10.8 -11.2 01/23/2006 10:20:00 11.9 1.7 19.1 8 11.7 1.6 18.3 7.6 9.6 1.3 14.5 5.7 304 8 302 165 -10.8 0 -10.6 -11 01/23/2006 10:30:00 10.9 1.7 16.8 6.5 10.7 1.7 17.2 6.1 8.6 1.7 13.7 4.9 301 8 287 165 -10.8 0 -10.6 -11 01/23/2006 10:40:00 10.4 1.3 13.7 7.2 10.2 1.2 13.3 7.2 8.5 1.5 13 4.9 298 8 292 165 -10.6 0 -10.4 -10.8 01/23/2006 10:50:00 11.7 1.5 15.6 8 11.6 1.5 15.6 8 9.1 1.5 13.3 5.3 298 6 293 165 -10.5 0 -10.4 -10.6 01/23/2006 11:00:00 11.5 1.7 15.3 7.2 11.3 1.7 15.3 6.8 9.1 1.3 12.6 5.7 299 8 292 165 -10.4 0 -10.2 -10.6 01/23/2006 11:10:00 10.3 1.5 14.1 6.8 10.1 1.5 13.3 6.5 8.3 1.4 11.8 5.3 302 8 300 165 -10.3 0 -10.2 -10.4 01/23/2006 11:20:00 10.3 1.3 13.7 6.5 10.2 1.3 13.3 6.1 8.4 1.3 11.8 5.3 303 9 296 165 -10.2 0 -10 -10.4 01/23/2006 11:30:00 11 1.2 14.1 7.6 10.8 1.2 13.7 6.8 8.4 1.2 11.5 5.3 303 6 302 165 -10 0 -9.7 -10.2 01/23/2006 11:40:00 9.4 1.2 12.6 5.7 9.2 1.2 13 5.7 7.6 1.1 11.5 4.9 303 9 304 165 -9.5 0 -9.3 -9.7 01/23/2006 11:50:00 8.3 1.4 11.8 3.8 8.2 1.4 11.8 4.6 7.2 1.5 10.7 3.8 307 12 304 165 -9.3 0.1 -9.1 -9.7 01/23/2006 12:00:00 9.7 1.5 13.7 5.7 9.6 1.5 13.3 5.7 8.2 1.6 12.2 4.2 294 10 282 165 -9.3 0.1 -9.1 -9.7 01/23/2006 12:10:00 9.9 2 14.5 4.6 9.8 2 14.5 4.6 8.9 2.1 14.9 3.8 291 10 291 165 -9.5 0 -9.3 -9.7 01/23/2006 12:20:00 9.4 2.3 15.3 3.4 9.4 2.2 14.5 4.2 8.2 2 14.1 3.8 287 10 293 165 -9.5 0 -9.3 -9.7 01/23/2006 12:30:00 10.9 1.7 14.5 6.1 10.7 1.7 14.1 5.7 8.6 1.7 13.7 4.9 299 9 294 165 -9.4 0 -9.3 -9.7 01/23/2006 12:40:00 10.1 2.1 15.6 3.8 10 2.1 15.6 4.6 8.2 1.8 13.3 3.8 295 12 283 165 -9.3 0 -9.1 -9.5 01/23/2006 12:50:00 7 1.8 14.5 2.6 7 1.9 14.5 2.6 6.5 1.8 14.5 3.4 296 19 288 165 -9.2 0.2 -8.7 -9.5 01/23/2006 13:00:00 9.8 2 16.4 6.1 9.7 2 16.1 6.1 7.8 1.8 14.1 4.2 296 8 307 165 -9.4 0.2 -9.1 -9.7 01/23/2006 13:10:00 9.5 1.7 14.5 4.9 9.3 1.7 14.1 4.6 8.4 1.4 12.6 5.3 311 11 295 165 -9.4 0 -9.1 -9.7 01/23/2006 13:20:00 10.4 1.5 14.9 7.2 10.3 1.5 14.5 7.2 8.6 1.2 11.8 4.9 305 8 295 165 -9.4 0 -9.3 -9.7 01/23/2006 13:30:00 10.2 2 16.4 6.1 10 2 16.1 6.5 8.4 1.7 14.5 4.9 306 9 291 165 -9.2 0.1 -8.9 -9.5 01/23/2006 13:40:00 10.8 1.6 16.4 5.7 10.7 1.6 15.6 5.7 8.7 1.5 14.5 4.9 305 7 291 165 -9.2 0 -8.9 -9.3 01/23/2006 13:50:00 11.3 1.5 15.3 7.6 11.2 1.5 14.9 7.2 9.1 1.4 13.3 5.7 305 7 309 165 -9.3 0 -9.1 -9.5 01/23/2006 14:00:00 11.6 1.5 16.1 8 11.5 1.4 14.9 7.6 8.7 1.4 14.1 6.1 304 6 291 165 -9.3 0 -9.1 -9.5 01/23/2006 14:10:00 11.6 1.7 16.1 6.8 11.5 1.6 15.6 6.8 9.4 1.8 15.6 5.7 303 9 307 165 -9.2 0 -9.1 -9.3 01/23/2006 14:20:00 11.2 1.4 14.9 7.6 11 1.4 14.9 7.2 9 1.5 14.9 6.1 301 11 302 165 -9.3 0 -9.1 -9.5 01/23/2006 14:30:00 11 1.5 13.7 7.2 10.9 1.5 13.7 7.2 8.6 1.4 12.6 4.9 296 8 306 165 -9.6 0 -9.5 -9.7 01/23/2006 14:40:00 10.4 1.1 14.1 7.6 10.3 1.1 14.1 7.2 8.2 1.2 13 5.3 301 8 308 165 -9.6 0.1 -9.1 -9.7 01/23/2006 14:50:00 11.1 1.3 14.5 7.6 10.9 1.3 14.5 7.6 8.8 1.4 13.3 5.7 298 8 290 165 -9.5 0.1 -9.3 -9.7 01/23/2006 15:00:00 11.1 1.5 13.7 7.6 10.9 1.5 13.7 7.2 8.6 1.5 13 4.9 298 7 301 165 -9.4 0.2 -9.1 -9.7 01/23/2006 15:10:00 12 1.5 17.6 9.1 11.9 1.5 17.2 8.8 9.6 1.8 14.9 5.7 296 7 294 165 -9.5 0.1 -9.3 -9.7 01/23/2006 15:20:00 11.1 1.7 15.3 7.2 10.9 1.6 14.9 7.2 8.7 1.5 13.7 5.3 299 8 300 165 -9.6 0 -9.3 -9.7 01/23/2006 15:30:00 9.7 1.6 14.1 5.3 9.6 1.6 14.1 5.7 8.4 1.5 13.3 4.9 312 13 295 165 -9.3 0.2 -9.1 -9.7 01/23/2006 15:40:00 11 1.9 16.1 5.3 10.8 1.7 15.6 5.7 10.3 1.7 15.3 5.7 330 13 356 165 -8.8 0.1 -8.5 -9.3 01/23/2006 15:50:00 10.1 1.7 14.5 6.8 10 1.7 14.9 6.5 9.2 1.7 13.7 5.7 325 15 342 165 -8.7 0.1 -8.5 -9.1 01/23/2006 16:00:00 9.8 1.9 14.5 5.3 9.6 1.8 14.9 5.3 8.2 1.7 13 4.6 310 15 305 165 -9 0 -8.9 -9.1 01/23/2006 16:10:00 9.7 2 15.3 3.8 9.6 2 14.9 3.8 8.2 2 13 3 314 14 301 165 -9.1 0 -8.9 -9.1 01/23/2006 16:20:00 10.6 1.8 13.7 6.5 10.5 1.7 13.7 6.1 8.6 2 14.1 3.4 306 10 281 165 -9.5 0.2 -8.9 -10 01/23/2006 16:30:00 8 2.2 12.2 3.4 7.9 2.1 12.2 3.4 6.4 1.7 11.1 1.9 307 17 305 165 -9.9 0 -9.7 -10 01/23/2006 16:40:00 6.8 2.2 13.3 0.4 6.7 2.3 13 0.7 5.8 2 11.8 1.5 316 19 321 165 -9.9 0 -9.7 -10.2 01/23/2006 16:50:00 8.5 1.9 14.1 4.6 8.3 1.8 14.1 4.9 7.6 1.9 14.1 4.2 328 16 351 165 -9.6 0.1 -9.3 -10 01/23/2006 17:00:00 12.8 2.8 18.7 7.2 12.3 3.1 19.1 5.7 11.4 2.9 17.9 4.9 343 12 347 165 -9.3 0 -9.1 -9.3 01/23/2006 17:10:00 11.3 2.7 17.6 5.3 10.3 2.4 16.4 4.9 10 2.4 16.8 4.2 342 17 356 165 -9.2 0 -9.1 -9.5 01/23/2006 17:20:00 11.5 3.1 17.9 4.9 10.7 2.7 18.7 5.3 10.4 2.9 18.7 4.6 340 16 347 165 -9.3 0 -9.1 -9.3 01/23/2006 17:30:00 8.5 1.5 13.7 5.7 8.3 1.6 13.7 5.3 7.9 1.7 13.7 4.6 323 15 351 165 -9.5 0.1 -9.3 -9.7 01/23/2006 17:40:00 8.7 2.3 15.6 3.8 8.4 2.2 16.8 3.4 7.9 2.2 16.4 4.2 328 17 345 165 -9.5 0 -9.3 -9.7 01/23/2006 17:50:00 10 2.4 19.1 4.6 9.5 2.5 19.1 3.8 8.8 2.5 17.2 3.8 334 17 343 165 -9.3 0 -9.1 -9.5 01/23/2006 18:00:00 9.9 2.3 15.6 4.9 9.6 2.4 16.4 3.8 8.9 2.3 16.1 4.2 338 13 346 165 -9.1 0 -9.1 -9.3 01/23/2006 18:10:00 11.7 2.4 17.9 5.3 11.3 2.7 18.7 4.6 10.7 2.3 18.3 5.3 341 12 336 165 -9.1 0 -8.9 -9.1 01/23/2006 18:20:00 14.6 1.9 19.5 9.5 14.3 2.2 19.1 7.6 13.8 2 19.5 8.4 341 10 346 165 -9.1 0 -8.9 -9.1 01/23/2006 18:30:00 13.6 1.9 18.7 9.1 13.4 2 19.1 9.1 13 1.9 17.9 8.4 339 9 350 165 -9.1 0 -8.9 -9.1 01/23/2006 18:40:00 12.5 1.7 18.3 8 12.2 1.8 17.2 6.8 12 2 17.9 6.5 337 10 354 165 -9.1 0 -8.9 -9.1 01/23/2006 18:50:00 13.3 1.8 17.2 7.6 13.4 2 18.3 7.2 12.6 2 17.2 7.6 338 7 345 165 -9.1 0 -8.9 -9.1 01/23/2006 19:00:00 11.4 2 16.4 6.8 10.9 2.3 16.8 5.3 10.8 2.2 16.1 4.9 339 14 345 165 -9.1 0 -8.9 -9.1 01/23/2006 19:10:00 11.6 2.2 18.7 4.6 11 2.5 18.7 4.6 10.6 2.2 17.6 4.9 343 14 354 165 -9.1 0 -9.1 -9.3 01/23/2006 19:20:00 6.7 2.3 11.8 2.3 6.3 2.2 10.7 1.5 6.2 2.4 11.1 0.7 329 24 11 165 -9.1 0 -8.9 -9.3 01/23/2006 19:30:00 10.9 2.5 18.3 4.9 9.6 2.5 18.7 4.2 10.3 2.5 17.9 4.9 351 12 354 165 -9.2 0 -9.1 -9.3 01/23/2006 19:40:00 7.2 2.6 13.3 1.1 7.1 2.6 13 0.7 6.2 2.2 11.5 1.1 315 24 298 165 -9.1 0 -8.9 -9.3 01/23/2006 19:50:00 5.2 2.4 11.1 0.4 5.1 2.4 10.7 0.4 4.4 1.9 10.7 0.4 312 33 286 165 -9.1 0 -8.9 -9.1 01/23/2006 20:00:00 6.5 1.8 11.8 2.6 6.4 1.9 11.8 2.3 5.6 1.5 9.9 2.3 311 18 307 165 -9.1 0 -8.9 -9.1 01/23/2006 20:10:00 11.5 2.5 17.2 3.8 11.3 2.5 17.2 3.4 9.4 2.4 17.6 2.3 305 11 300 165 -9 0 -8.9 -9.3 01/23/2006 20:20:00 11.4 2.4 18.3 3 11.3 2.3 17.6 3.4 9.4 2.3 16.1 3 308 9 314 165 -9 0.1 -8.9 -9.1 01/23/2006 20:30:00 9.8 2.2 15.3 3.8 9.7 2.3 15.6 3.4 7.5 2.4 13.3 1.5 306 17 304 165 -9.1 0 -8.9 -9.3 01/23/2006 20:40:00 10.4 2.7 16.1 3 10.3 2.6 15.6 3.8 7.3 2.5 14.1 0.4 301 38 289 165 -9.2 0 -9.1 -9.3 01/23/2006 20:50:00 11.7 2.1 17.2 4.2 11.6 2.2 17.6 4.6 8.7 2.2 14.1 2.3 303 12 301 165 -9.2 0 -8.9 -9.3 01/23/2006 21:00:00 10.2 2.3 14.9 3.8 10.1 2.3 14.5 3.8 7.6 2.3 12.6 1.9 300 16 297 165 -9.2 0 -8.9 -9.3 01/23/2006 21:10:00 8.8 2.3 17.6 3.4 8.8 2.3 17.2 3 6.7 2.2 14.9 1.9 304 17 321 165 -9.2 0 -9.1 -9.3 01/23/2006 21:20:00 5.7 2.3 12.2 0.4 5.5 2.4 13.3 0.4 4.3 2 10.3 0.4 316 43 313 165 -9.1 0 -8.9 -9.3 01/23/2006 21:30:00 7.5 2 14.5 2.3 7.4 2 13.7 1.9 5.7 1.9 13 1.5 297 20 299 165 -9.2 0 -8.9 -9.5 01/23/2006 21:40:00 8.7 1.8 14.1 4.9 8.7 1.8 13.7 4.6 6.7 1.7 11.8 2.6 298 14 297 165 -9.4 0 -9.3 -9.5 01/23/2006 21:50:00 9.8 2.5 14.5 2.6 9.6 2.5 14.5 2.3 7.7 2.6 13.3 0.7 305 18 297 165 -9.3 0 -9.1 -9.7 01/23/2006 22:00:00 8.8 2.8 15.3 1.5 8.6 2.8 14.9 1.9 6.3 2.6 11.8 1.1 297 18 296 165 -9.4 0 -9.1 -9.5 01/23/2006 22:10:00 9 1.8 14.5 4.6 8.8 1.9 14.1 1.1 6.1 2 13 1.5 302 16 297 165 -9.3 0 -9.1 -9.3 01/23/2006 22:20:00 9.9 2.3 15.3 3 9.8 2.3 15.6 2.6 7.1 2.1 13 2.3 297 27 300 165 -9.2 0 -9.1 -9.3 01/23/2006 22:30:00 9.9 2 15.6 5.3 9.8 2.1 15.3 3.8 7.2 2.4 11.8 1.1 307 15 318 165 -9.1 0 -8.9 -9.1 01/23/2006 22:40:00 9.8 2 14.1 4.9 9.8 2.1 13.7 3.8 6.9 2 13 2.3 307 12 307 165 -9 0 -8.9 -9.1 01/23/2006 22:50:00 9.5 2.4 14.9 4.2 9.4 2.4 15.3 3.8 6.7 2.4 13.7 1.9 310 16 310 165 -8.9 0 -8.7 -9.1 01/23/2006 23:00:00 10.2 2 15.6 4.2 10.1 2.1 14.9 4.6 9.1 2.4 16.4 3 323 15 328 165 -8.7 0.2 -8.3 -8.9 01/23/2006 23:10:00 12.3 2.1 17.9 6.5 12.1 2.2 17.6 5.7 10.7 2.1 15.6 5.7 317 13 309 165 -8.3 0 -8.1 -8.5 01/23/2006 23:20:00 12.4 1.6 17.2 7.6 12.5 1.6 17.6 7.6 10.5 2.2 16.4 4.9 314 8 309 165 -8.3 0 -8.1 -8.5 01/23/2006 23:30:00 12.8 1.7 16.8 8.4 12.8 1.8 16.8 8 10.7 2.2 16.1 5.3 315 10 308 165 -8.3 0 -8.1 -8.5 01/23/2006 23:40:00 12.9 1.9 17.2 8.4 12.9 1.8 16.8 7.6 11.4 2.1 16.1 4.6 314 8 308 165 -8.1 0 -8.1 -8.5 01/23/2006 23:50:00 14.3 1.8 18.3 9.1 14.2 1.8 17.9 8.8 12.7 2 17.6 7.6 311 7 314 165 -8.2 0 -8.1 -8.3 01/24/2006 00:00:00 16 1.7 18.7 8.8 15.8 1.6 18.3 8.8 14.8 2 18.3 8 316 6 312 165 -8.3 0 -8.1 -8.5 01/24/2006 00:10:00 17.6 1 20.6 14.5 17.5 1 20.2 14.5 16.7 1.3 19.5 12.2 317 5 321 165 -8.3 0 -8.3 -8.5 01/24/2006 00:20:00 17.1 1.2 19.5 13 17 1.2 19.5 12.6 15.8 1.3 18.3 12.2 313 5 310 165 -8.4 0 -8.3 -8.5 01/24/2006 00:30:00 17.3 0.9 19.1 14.5 17.2 0.9 18.7 14.1 15.5 1.1 18.3 12.2 311 4 313 165 -8.4 0 -8.3 -8.5 01/24/2006 00:40:00 17.4 1.2 20.2 13.3 17.3 1.2 20.2 13.3 15.1 1.3 17.9 10.7 310 5 307 165 -8.5 0 -8.3 -8.5 01/24/2006 00:50:00 17.9 1.1 20.2 13.3 17.7 1.1 20.6 14.1 15.5 1.3 18.7 11.1 309 4 307 165 -8.5 0 -8.3 -8.5 01/24/2006 01:00:00 17.4 1 19.5 13.7 17.2 1 19.5 14.1 14.9 1.4 19.1 11.1 309 4 309 165 -8.5 0 -8.5 -8.5 01/24/2006 01:10:00 16.8 1.2 19.1 13.3 16.6 1.2 19.1 13 14.1 1.7 17.9 8.8 308 4 310 165 -8.6 0 -8.5 -8.7 01/24/2006 01:20:00 16.2 1.5 19.5 12.2 16.1 1.5 19.1 12.6 14.2 1.6 18.3 10.3 309 4 310 165 -8.7 0 -8.5 -8.7 01/24/2006 01:30:00 16.6 1.8 19.9 12.2 16.5 1.8 19.9 11.8 15.2 1.7 19.1 9.1 310 5 303 165 -8.8 0 -8.5 -8.9 01/24/2006 01:40:00 18.9 0.9 20.6 16.1 18.8 0.9 20.6 15.6 17.6 1.2 20.2 13.7 312 3 309 165 -8.7 0 -8.5 -8.9 01/24/2006 01:50:00 18.7 0.9 20.6 16.1 18.6 0.9 20.6 16.1 17.4 1 19.9 14.1 312 4 310 165 -8.7 0 -8.5 -8.9 01/24/2006 02:00:00 18.7 1.2 21.4 15.6 18.7 1.2 21.4 15.6 18.2 1.3 21 15.3 315 4 310 165 -8.8 0 -8.7 -8.9 01/24/2006 02:10:00 17.9 1.1 20.2 14.5 17.8 1.1 20.2 14.5 17.4 1.2 20.6 13.7 316 4 310 165 -8.8 0 -8.7 -8.9 01/24/2006 02:20:00 17.9 0.9 19.9 15.3 17.9 0.9 20.2 14.9 17.8 0.9 19.9 15.3 318 4 313 165 -9 0 -8.7 -9.1 01/24/2006 02:30:00 16.6 1 19.1 13.3 16.4 1 18.7 12.6 16.2 1.2 18.7 12.6 323 5 328 165 -9 0 -8.7 -9.1 01/24/2006 02:40:00 17.2 1.3 20.6 13 17.1 1.3 20.6 13.7 17 1.4 21 13.3 323 5 313 165 -8.8 0 -8.5 -8.9 01/24/2006 02:50:00 16.1 1.3 19.5 12.6 15.9 1.3 19.5 12.2 15.5 1.4 18.7 11.5 320 5 314 165 -9 0 -8.9 -9.1 01/24/2006 03:00:00 15.7 1.3 18.7 11.8 15.6 1.3 18.3 11.8 15.1 1.4 17.9 11.1 321 6 313 165 -9.1 0 -8.9 -9.1 01/24/2006 03:10:00 16.1 1.4 19.9 9.9 15.9 1.4 19.9 10.3 15.5 1.6 19.1 10.7 322 6 317 165 -8.9 0 -8.7 -9.1 01/24/2006 03:20:00 16.2 1.2 18.3 11.1 16.1 1.1 18.3 11.5 15.5 1.5 17.9 11.5 319 5 316 165 -9.1 0.1 -8.9 -9.1 01/24/2006 03:30:00 16.9 0.8 18.7 13.7 16.8 0.8 18.7 13.7 16.5 1 19.1 12.6 319 3 317 165 -9.1 0 -8.9 -9.1 01/24/2006 03:40:00 16.2 1 18.3 11.8 16.1 1 18.3 12.2 15.7 1.1 18.3 11.1 317 4 314 165 -9.1 0 -8.9 -9.1 01/24/2006 03:50:00 15.8 0.9 17.9 13 15.7 0.9 17.9 13 15.5 1.2 19.1 12.6 317 5 319 165 -9 0 -8.9 -9.1 01/24/2006 04:00:00 16.2 1 18.7 13 16.1 1 18.7 13.3 15.6 1 18.7 12.2 315 4 312 165 -9.1 0 -8.9 -9.1 01/24/2006 04:10:00 15.5 1 17.9 12.2 15.3 1 17.6 11.8 14.5 1.2 17.6 11.1 313 4 310 165 -9.1 0 -8.9 -9.1 01/24/2006 04:20:00 12.9 1.6 16.8 9.1 12.7 1.6 16.8 8.4 12 1.7 16.8 7.2 315 7 321 165 -9 0 -8.9 -9.1 01/24/2006 04:30:00 11.3 1.4 15.3 7.2 11.3 1.3 14.9 7.2 9.9 1.5 13 4.9 313 8 302 165 -8.8 0.1 -8.5 -8.9 01/24/2006 04:40:00 10.7 1.3 13.3 6.8 10.7 1.5 13.3 6.5 8.6 1.8 13 3.4 312 9 296 165 -8.5 0 -8.3 -8.7 01/24/2006 04:50:00 10.8 1.2 13.3 6.1 10.8 1.2 13.3 6.8 9.5 1.7 13.3 4.6 312 6 313 165 -8.7 0 -8.5 -8.9 01/24/2006 05:00:00 12.3 1.5 15.3 8.4 12.2 1.3 14.9 8.8 11.2 1.6 14.9 7.6 319 6 325 165 -9 0.1 -8.7 -9.1 01/24/2006 05:10:00 13.7 1.6 17.2 9.1 13.4 1.6 16.8 9.1 12.9 1.8 17.2 8 327 6 328 165 -9.1 0 -8.9 -9.1 01/24/2006 05:20:00 14.9 1.1 17.2 11.5 14.7 1.1 17.2 11.5 14.5 1.3 17.2 10.3 321 6 328 165 -9 0 -8.9 -9.1 01/24/2006 05:30:00 14 0.7 15.6 11.5 13.9 0.7 15.6 11.1 12.8 1.4 16.4 8.4 312 4 310 165 -8.9 0 -8.7 -9.1 01/24/2006 05:40:00 13.5 0.9 15.6 10.3 13.4 0.9 15.6 10.3 10.6 1.3 14.1 7.6 307 5 304 165 -9 0 -8.9 -9.1 01/24/2006 05:50:00 12.6 0.9 16.4 11.1 12.5 0.9 16.4 10.7 10 1.5 15.3 6.8 308 4 314 165 -9 0 -8.9 -9.1 01/24/2006 06:00:00 11.8 0.9 13.7 9.5 11.6 0.9 13.7 9.5 10.4 1.2 13.3 6.8 312 5 311 165 -9.1 0 -8.9 -9.1 01/24/2006 06:10:00 11.7 0.9 13.7 9.5 11.7 0.9 13.7 8.8 10.5 1.2 13.3 7.6 311 4 311 165 -9.1 0 -8.9 -9.3 01/24/2006 06:20:00 12.1 1 14.5 9.1 11.9 1 14.1 9.1 10.8 1.1 13.7 7.6 312 4 311 165 -9.1 0 -8.9 -9.1 01/24/2006 06:30:00 12.4 1 15.6 9.5 12.2 1 15.3 9.1 11.4 1.1 15.6 8.4 314 5 322 165 -8.8 0 -8.5 -9.1 01/24/2006 06:40:00 13.5 0.9 15.6 10.3 13.3 1 15.6 10.3 12.8 1 14.9 10.3 315 4 312 165 -8.6 0 -8.5 -8.9 01/24/2006 06:50:00 13.9 0.8 16.1 11.1 13.8 0.8 16.1 11.1 13.6 0.7 15.6 11.1 317 4 312 165 -8.8 0 -8.5 -8.9 01/24/2006 07:00:00 11.3 0.8 13.7 9.1 11.2 0.8 13.3 8.8 11.2 0.9 13.3 8.8 322 5 329 165 -8.7 0 -8.5 -8.9 01/24/2006 07:10:00 11.3 0.8 13.7 8.8 11.2 0.8 14.1 9.1 11 0.9 13 8.8 317 6 311 165 -8.7 0 -8.5 -8.9 01/24/2006 07:20:00 10.1 1 12.2 7.6 10 1 12.2 7.6 9.5 1.1 11.8 7.2 316 8 306 165 -9 0 -8.7 -9.1 01/24/2006 07:30:00 11 1.6 14.9 7.2 10.9 1.7 14.9 7.2 10.7 1.6 14.5 7.2 320 8 303 165 -9 0 -8.7 -9.1 01/24/2006 07:40:00 10.3 1.5 14.9 6.8 10.2 1.5 14.9 7.2 9.8 1.5 14.9 6.1 316 10 323 165 -8.9 0 -8.7 -9.1 01/24/2006 07:50:00 12 1.6 17.6 8.8 11.9 1.6 16.8 9.1 10.8 1.7 16.1 6.5 312 11 302 165 -8.9 0 -8.5 -9.1 01/24/2006 08:00:00 13.7 1.7 18.7 8.8 13.6 1.6 18.7 8.8 12.7 1.7 17.6 9.1 317 12 266 165 -8.4 0.2 -8.1 -8.9 01/24/2006 08:10:00 11.8 2 18.3 8 11.6 1.9 17.9 8 10.4 2.1 16.1 5.7 313 11 302 165 -8.4 0.1 -8.1 -8.7 01/24/2006 08:20:00 9.9 1.1 12.6 6.1 9.8 1.1 12.2 6.1 9.1 1.1 11.5 5.7 313 9 303 165 -8.4 0.1 -8.1 -8.7 01/24/2006 08:30:00 10 1.2 13 6.8 9.8 1.2 13 6.5 9.6 1.3 13.3 6.8 322 9 333 165 -8.3 0 -8.1 -8.5 01/24/2006 08:40:00 10.6 1.1 14.5 8 10.4 1.1 14.1 8 8.7 1.3 12.2 6.1 306 10 300 165 -8.5 0.1 -8.1 -8.9 01/24/2006 08:50:00 11.2 1.3 14.9 8 11.1 1.3 14.5 8.4 9.4 1.2 12.2 6.1 307 7 297 165 -8.6 0 -8.5 -8.9 01/24/2006 09:00:00 11.7 1 15.3 8.4 11.7 1 14.5 8.4 10.2 1.4 13.3 6.8 310 6 304 165 -8.6 0 -8.5 -8.7 01/24/2006 09:10:00 10.8 1.1 14.1 8.4 10.7 1.1 13.7 8.4 9.8 1.4 14.1 6.5 313 7 307 165 -8.6 0.1 -8.3 -8.9 01/24/2006 09:20:00 9 1.3 12.6 6.5 8.9 1.3 12.6 6.1 7.8 1.5 12.6 4.9 312 9 309 165 -8.7 0.1 -8.5 -8.9 01/24/2006 09:30:00 8.4 1 12.2 5.7 8.2 1 12.2 6.1 7.3 0.9 10.3 4.9 310 8 314 165 -8.8 0 -8.5 -8.9 01/24/2006 09:40:00 9.1 1.2 12.2 6.1 9 1.2 11.8 5.7 7.5 0.9 9.9 5.3 310 11 318 165 -8.6 0 -8.5 -8.7 01/24/2006 09:50:00 9.5 1.5 13.3 5.7 9.4 1.5 12.6 5.7 7.8 1.3 11.5 4.9 305 11 305 165 -8.3 0.1 -8.1 -8.7 01/24/2006 10:00:00 11.4 1.3 15.6 8 11.2 1.3 15.3 8 9.4 1.4 13 6.5 308 7 290 165 -8.1 0 -7.9 -8.3 01/24/2006 10:10:00 12.6 1.5 16.1 8 12.5 1.5 16.1 8.4 10.3 1.5 15.3 6.5 308 7 308 165 -8.1 0 -8.1 -8.3 01/24/2006 10:20:00 11.6 1.3 15.6 8.8 11.5 1.3 15.3 8.8 10.1 1.1 13.3 6.5 311 8 298 165 -7.9 0 -7.6 -8.1 01/24/2006 10:30:00 11.5 1.1 14.9 9.1 11.4 1.1 14.5 8.8 10.2 1.1 13.7 7.2 311 8 308 165 -7.8 0 -7.6 -7.9 01/24/2006 10:40:00 11.4 1.3 16.4 8 11.3 1.3 16.1 8 10.1 1.4 14.1 6.8 312 11 310 165 -7.6 0.1 -7.4 -7.9 01/24/2006 10:50:00 9.6 1.4 13.3 6.5 9.4 1.3 13 6.5 8.1 1.4 12.2 4.6 307 11 309 165 -7.5 0 -7.2 -7.6 01/24/2006 11:00:00 10.3 1.4 13.7 6.1 10.2 1.3 13.7 6.1 8.8 1.6 13.3 5.7 310 9 319 165 -7.5 0.1 -7.2 -7.6 01/24/2006 11:10:00 10.6 1.5 14.9 6.1 10.5 1.5 14.1 6.1 9 1.4 14.1 5.3 309 9 311 165 -7.4 0 -7.2 -7.4 01/24/2006 11:20:00 11.1 1.4 15.3 7.2 11 1.4 14.5 6.8 8.9 1.4 13.7 5.3 303 8 304 165 -7.5 0 -7.2 -7.6 01/24/2006 11:30:00 10.4 1.7 14.9 6.5 10.3 1.7 14.5 6.1 8.4 1.3 13.7 5.3 304 10 300 165 -7.4 0.1 -7 -7.4 01/24/2006 11:40:00 9.6 1.7 15.3 5.7 8.9 1.9 15.3 4.6 8.7 2 16.4 4.2 328 23 350 165 -6.8 0.2 -6.1 -7.2 01/24/2006 11:50:00 7.6 1.6 11.8 3.8 7.6 1.6 11.5 4.2 6.8 1.5 10.7 3.8 314 17 300 165 -6.5 0.1 -6.1 -6.8 01/24/2006 12:00:00 9.5 1.7 13 5.3 9.4 1.6 12.6 4.6 7.7 1.2 10.7 5.3 305 11 294 165 -6.9 0.1 -6.6 -7 01/24/2006 12:10:00 9.8 1.5 14.9 6.1 9.7 1.5 14.5 6.1 7.9 1.3 13 4.6 303 8 304 165 -7 0 -6.8 -7.2 01/24/2006 12:20:00 10.1 1.4 13.7 6.8 10 1.3 13.7 6.8 8.7 1.4 12.6 4.6 307 9 298 165 -7 0 -6.8 -7.2 01/24/2006 12:30:00 9.2 1.9 13.3 3.8 9.1 1.8 13 3.8 7.7 1.6 11.8 3.8 302 11 302 165 -6.9 0 -6.8 -7 01/24/2006 12:40:00 8.9 1.5 12.6 3.8 8.9 1.5 13 3.8 7.4 1.7 13 3 296 9 293 165 -6.9 0.1 -6.6 -7.2 01/24/2006 12:50:00 9.5 1.3 12.6 5.7 9.4 1.3 11.8 6.1 7.7 1.4 13 4.2 306 10 290 165 -6.9 0.1 -6.6 -7 01/24/2006 13:00:00 11.5 1.1 13.7 8.8 11.4 1.1 13.7 8.4 8.8 1.2 12.6 6.1 305 5 298 165 -7.1 0 -6.8 -7.2 01/24/2006 13:10:00 12.1 1 14.9 9.9 12 1 14.5 9.5 10 1.4 14.1 6.8 308 5 316 165 -7.1 0 -6.8 -7.2 01/24/2006 13:20:00 12.3 1.3 15.3 8.8 12.2 1.2 14.9 8.8 9.9 1.5 13.7 6.5 306 6 305 165 -7.1 0 -6.8 -7.2 01/24/2006 13:30:00 12.5 1 16.1 10.3 12.4 1 15.6 9.9 9.3 1.3 13 6.1 301 6 296 165 -7.2 0 -7 -7.2 01/24/2006 13:40:00 12.2 1 14.5 9.5 12.1 1 14.5 9.1 8.9 1.1 11.8 6.1 304 4 305 165 -7.1 0 -6.8 -7.2 01/24/2006 13:50:00 10.9 1 13.3 8.4 10.8 1 13.3 8.4 9.4 1.1 13 6.5 310 5 300 165 -6.9 0.1 -6.8 -7.2 01/24/2006 14:00:00 10.2 1 12.6 8 10.1 1 12.2 7.6 8.4 1.1 11.8 5.7 309 6 305 165 -6.7 0 -6.6 -6.8 01/24/2006 14:10:00 10.9 0.9 13.3 8.4 10.8 1 13.3 8 9.7 1.3 13 6.5 313 7 314 165 -6.5 0 -6.4 -6.8 01/24/2006 14:20:00 10.2 1.2 13.3 7.6 10.1 1.2 13.3 7.2 8.7 1.1 11.8 6.1 309 8 300 165 -6.4 0 -6.4 -6.6 01/24/2006 14:30:00 9.5 1.1 12.2 6.8 9.4 1 12.2 6.8 7.9 1.1 11.1 4.9 308 7 298 165 -6.3 0 -6.1 -6.6 01/24/2006 14:40:00 9.7 1.6 13.3 4.6 9.5 1.6 13 4.2 8.5 1.5 12.2 4.9 312 7 319 165 -6.1 0.2 -5.7 -6.4 01/24/2006 14:50:00 10.7 1.5 14.5 5.7 10.5 1.5 14.1 5.7 9.5 1.5 13.3 5.3 312 9 302 165 -6 0 -5.7 -6.4 01/24/2006 15:00:00 10.7 1.2 14.1 7.6 10.7 1.2 14.5 7.2 9.7 1.3 12.6 5.3 314 8 315 165 -6.1 0 -5.9 -6.4 01/24/2006 15:10:00 11.4 1.3 14.5 6.5 11.3 1.3 13.7 6.8 10.1 1.6 13 5.3 314 8 313 165 -6.1 0.1 -5.7 -6.4 01/24/2006 15:20:00 11.4 1.5 14.9 6.5 11.4 1.5 15.6 5.7 9.8 1.9 14.1 3.8 311 9 316 165 -6 0 -5.7 -6.1 01/24/2006 15:30:00 9.3 1.7 13.7 5.3 9.3 1.7 14.1 4.9 7.6 1.9 12.6 3 316 11 309 165 -5.8 0.1 -5.5 -6.1 01/24/2006 15:40:00 9.4 1.7 14.5 4.2 9.3 1.7 14.1 4.2 8.1 2.1 13 3 319 11 319 165 -5.8 0.1 -5.5 -6.1 01/24/2006 15:50:00 8.8 2 14.5 4.2 8.9 2 15.3 4.6 7.6 2.3 13 3 315 11 325 165 -5.8 0.1 -5.5 -6.1 01/24/2006 16:00:00 10 2.2 14.9 1.9 10 2.2 15.3 3 8.3 2.6 13.7 1.5 321 21 306 165 -6 0.1 -5.7 -6.1 01/24/2006 16:10:00 12.1 2.3 17.9 3.8 12 2.3 17.9 3.8 10.7 2.7 16.8 2.6 317 11 310 165 -6.2 0.1 -5.9 -6.6 01/24/2006 16:20:00 13.2 1.9 17.6 8 13.1 1.9 18.3 8 11.9 2.3 17.6 6.1 316 9 308 165 -6.4 0 -6.1 -6.6 01/24/2006 16:30:00 13.3 1.7 17.2 7.2 13.2 1.7 16.8 7.6 11.9 1.9 16.8 6.1 314 8 310 165 -6.7 0 -6.4 -6.8 01/24/2006 16:40:00 12 1.7 16.1 7.6 11.9 1.7 16.1 8 10.7 1.7 15.3 6.8 316 11 312 165 -6.9 0.1 -6.6 -7.2 01/24/2006 16:50:00 13.6 2.3 18.7 8 13.5 2.3 18.3 8 13 2.4 18.3 6.5 323 9 325 165 -7.1 0 -6.8 -7.2 01/24/2006 17:00:00 11.8 2.3 16.8 4.9 11.7 2.4 16.4 4.2 10.5 2.7 15.6 3 322 13 336 165 -7.1 0 -7 -7.2 01/24/2006 17:10:00 11 2 15.3 5.7 11 2 15.3 4.9 9.6 2.2 14.5 1.5 322 12 310 165 -7.2 0 -7 -7.4 01/24/2006 17:20:00 11.4 1.8 15.6 6.8 11.4 1.8 15.6 6.5 10.4 2 15.6 5.3 327 9 324 165 -7.3 0 -7.2 -7.4 01/24/2006 17:30:00 13.7 1.7 17.2 8.8 13.6 1.6 17.2 9.1 13.1 1.7 17.6 8.8 327 7 323 165 -7.1 0 -6.8 -7.2 01/24/2006 17:40:00 13.9 1.1 16.8 11.1 13.8 1.1 17.2 11.1 13.6 1.1 16.4 9.5 324 8 331 165 -7.1 0 -6.8 -7.2 01/24/2006 17:50:00 13 1.4 17.2 9.1 12.8 1.4 17.2 8.8 12.8 1.5 16.4 9.5 324 9 314 165 -7.2 0 -6.8 -7.2 01/24/2006 18:00:00 12 1.2 15.3 9.5 12 1.2 15.3 9.1 11.6 1.3 14.9 8 318 7 315 165 -7.3 0 -7 -7.4 01/24/2006 18:10:00 12.3 1.2 16.1 9.1 12.2 1.2 16.1 9.1 11.7 1.4 16.1 7.2 317 8 307 165 -7.4 0 -7.2 -7.4 01/24/2006 18:20:00 12.9 1.1 16.1 9.1 12.8 1.1 16.1 8.8 12.5 1.2 16.4 9.1 320 7 319 165 -7.4 0.1 -7.2 -7.6 01/24/2006 18:30:00 12.6 1.2 16.1 9.1 12.5 1.1 15.6 9.1 12 1 14.5 8 320 9 297 165 -7.6 0 -7.4 -7.6 01/24/2006 18:40:00 12.5 1.1 15.6 8.8 12.4 1.1 15.6 9.1 12.3 1.3 15.3 8.8 327 9 314 165 -7.6 0 -7.4 -7.6 01/24/2006 18:50:00 12.4 1.5 15.6 8.8 12.3 1.5 15.6 8.8 12.2 1.9 16.1 8.4 325 9 326 165 -7.5 0 -7.2 -7.9 01/24/2006 19:00:00 11.5 1.5 16.1 8.4 11.4 1.5 16.1 8.4 11 1.6 15.6 7.2 322 9 318 165 -7.7 0 -7.4 -7.9 01/24/2006 19:10:00 11.9 1.1 14.5 8.8 11.7 1.1 14.5 8.4 11.6 1.2 14.9 8.8 325 7 328 165 -7.7 0 -7.4 -8.1 01/24/2006 19:20:00 12.3 1.2 15.3 8.4 12.2 1.2 14.9 8.8 11.9 1.3 15.6 8.8 323 8 310 165 -7.8 0.1 -7.4 -8.1 01/24/2006 19:30:00 13 1.2 16.8 9.1 12.9 1.2 16.8 9.1 12.8 1.2 16.1 9.1 327 8 314 165 -7.6 0 -7.4 -7.6 01/24/2006 19:40:00 13.1 1.3 16.4 10.3 13 1.3 16.4 9.9 13 1.3 16.1 9.5 322 7 328 165 -7.6 0 -7.4 -7.6 01/24/2006 19:50:00 12.1 1.1 15.6 9.9 12 1.1 15.6 9.9 11.9 1.3 16.4 9.1 321 6 323 165 -7.9 0 -7.6 -8.1 01/24/2006 20:00:00 14.9 1.6 19.1 10.7 14.7 1.6 19.5 10.3 14.8 1.7 19.1 10.3 326 7 316 165 -7.6 0.1 -7.2 -8.1 01/24/2006 20:10:00 16 1.1 18.7 13 15.9 1.1 18.7 13 15.5 1.2 19.1 12.6 320 7 307 165 -7.6 0 -7.4 -7.9 01/24/2006 20:20:00 13.8 1.9 17.2 9.1 13.6 1.8 17.2 9.1 13.1 2.1 17.2 6.8 322 6 327 165 -7.8 0 -7.6 -8.1 01/24/2006 20:30:00 8.3 1.7 13 3.8 8.3 1.9 13.3 2.6 6.7 2.4 11.5 1.1 315 13 317 165 -8 0 -7.6 -8.1 01/24/2006 20:40:00 7.8 1.8 13.3 3.8 7.7 1.9 13 3.4 6.4 2 11.8 2.6 312 12 296 165 -7.9 0 -7.6 -8.1 01/24/2006 20:50:00 7.3 1.6 10.7 2.6 7.2 1.6 11.1 2.6 6.3 1.7 10.3 1.9 315 20 322 165 -7.8 0 -7.4 -8.1 01/24/2006 21:00:00 5.7 1.3 9.5 1.9 5.6 1.3 9.9 2.3 5.1 1.2 8.4 2.3 323 17 308 165 -7.8 0 -7.6 -7.9 01/24/2006 21:10:00 8 2.1 13 3.8 7.9 2.1 13 3.8 7.2 1.7 10.7 3.8 316 11 307 165 -7.5 0 -7.4 -7.9 01/24/2006 21:20:00 7.9 1.5 11.5 4.9 7.5 1.6 11.1 4.2 7 1.6 10.7 3 329 21 310 165 -7.7 0 -7.4 -7.9 01/24/2006 21:30:00 6.8 1.4 10.3 3.8 6.7 1.4 10.3 3.4 6 1.5 10.7 3 312 15 333 165 -7.9 0 -7.6 -8.1 01/24/2006 21:40:00 6.1 1.2 9.5 2.6 5.9 1.3 9.9 2.6 5.4 1.2 8.4 1.9 330 20 325 165 -8 0.1 -7.6 -8.1 01/24/2006 21:50:00 6 1.7 10.7 3 5.7 1.7 10.3 2.6 5.4 1.5 10.3 2.3 330 19 303 165 -7.9 0.1 -7.6 -8.1 01/24/2006 22:00:00 4 1.3 8.4 1.5 3.7 1.3 8.4 1.5 3.4 1.2 8 1.5 339 22 323 165 -8.1 0 -7.9 -8.3 01/24/2006 22:10:00 2.8 1 4.9 0.4 2.6 1 4.9 0.4 2.3 1 4.6 0.4 332 29 9 165 -8.4 0 -8.1 -8.5 01/24/2006 22:20:00 2.5 0.7 3.8 0.4 2.4 0.7 3.8 0.4 2.5 0.7 3.8 0.4 35 22 19 165 -8.4 0.1 -8.1 -8.7 01/24/2006 22:30:00 3 0.6 4.6 1.5 2.8 0.5 3.8 1.1 3 0.6 4.6 1.1 28 14 12 165 -8.8 0 -8.5 -8.9 01/24/2006 22:40:00 4.6 0.9 7.2 2.6 3.5 1.1 7.2 1.9 4.5 0.8 7.2 2.6 0 11 355 165 -8.9 0 -8.7 -9.1 01/24/2006 22:50:00 4 0.7 5.7 2.3 3 0.8 5.3 1.5 4.1 0.6 5.7 2.6 358 11 0 165 -8.9 0 -8.7 -9.1 01/24/2006 23:00:00 4.7 0.8 6.5 1.9 4.1 1 6.8 1.9 4.7 0.8 6.5 2.3 350 10 359 165 -9 0.1 -8.7 -9.3 01/24/2006 23:10:00 4.2 0.6 6.1 2.6 4 0.6 6.1 2.6 4.1 0.5 5.7 3 342 8 344 165 -9.2 0 -9.1 -9.3 01/24/2006 23:20:00 4.3 0.6 6.1 3 4.2 0.6 6.5 2.6 4.2 0.6 6.8 3 331 9 348 165 -9.2 0 -8.9 -9.3 01/24/2006 23:30:00 4.7 0.6 6.1 3 4.5 0.7 6.1 2.3 4.6 0.6 6.1 3 332 9 332 165 -8.9 0 -8.7 -9.1 01/24/2006 23:40:00 4.2 0.6 6.1 2.3 3.9 0.7 5.7 1.9 4.2 0.8 6.1 2.3 339 12 349 165 -9 0.1 -8.7 -9.1 01/24/2006 23:50:00 2.5 0.5 3.4 1.5 2.2 0.5 3.4 1.1 2.1 0.5 3.4 0.4 342 11 338 165 -9.2 0 -8.9 -9.3 01/25/2006 00:00:00 0.7 0.5 2.3 0.4 0.6 0.4 2.3 0.4 0.6 0.4 2.3 0.4 316 9 347 165 -9.1 0 -8.9 -9.3 01/25/2006 00:10:00 0.5 0.3 1.5 0.4 0.5 0.2 1.5 0.4 0.5 0.2 1.5 0.4 245 28 206 165 -9 0 -8.9 -9.1 01/25/2006 00:20:00 1.4 0.4 1.9 0.4 1.4 0.4 1.9 0.4 1.1 0.4 2.3 0.4 276 22 283 165 -9.1 0 -8.9 -9.1 01/25/2006 00:30:00 1.4 0.2 1.9 1.1 1.3 0.2 1.9 0.7 1.1 0.2 1.5 0.7 306 4 309 165 -9.1 0 -8.9 -9.1 01/25/2006 00:40:00 1.3 0.3 1.9 0.7 1.2 0.3 1.9 0.7 1.2 0.2 1.9 0.7 316 9 312 165 -9.2 0.1 -9.1 -9.3 01/25/2006 00:50:00 1.3 0.4 2.3 0.4 1.1 0.5 2.3 0.4 1.1 0.4 1.9 0.4 331 11 343 165 -9.3 0.1 -8.9 -9.7 01/25/2006 01:00:00 2.7 0.4 3.8 1.5 2.5 0.5 3.8 1.1 2.5 0.5 4.2 1.5 340 6 346 165 -9.6 0 -9.3 -9.7 01/25/2006 01:10:00 2.4 0.4 3.4 1.5 2.2 0.4 3.4 1.1 2.2 0.4 3 1.1 340 4 334 165 -9.7 0 -9.3 -10 01/25/2006 01:20:00 2.2 0.4 3 1.5 2 0.4 3 1.1 1.8 0.4 3 1.1 327 8 328 165 -9.5 0.1 -9.3 -10 01/25/2006 01:30:00 1.7 0.4 2.6 0.7 1.6 0.4 2.3 0.7 1.4 0.4 2.3 0.4 311 11 330 165 -9.3 0.1 -9.1 -9.3 01/25/2006 01:40:00 2.1 0.5 3.4 1.1 2 0.5 3.4 1.1 1.7 0.4 2.6 0.7 287 7 298 165 -9.1 0 -8.9 -9.3 01/25/2006 01:50:00 3.8 0.4 4.9 3 3.7 0.4 4.6 3 3.1 0.5 4.2 1.9 307 5 310 165 -9.5 0.2 -9.1 -10 01/25/2006 02:00:00 3.3 0.6 4.6 1.5 3.2 0.6 4.2 1.5 2.9 0.4 3.8 1.5 322 10 313 165 -10.3 0.1 -10 -10.4 01/25/2006 02:10:00 3.9 0.5 4.9 2.6 3.8 0.4 4.9 2.6 3.3 0.4 4.2 1.9 312 8 310 165 -10.1 0.1 -9.7 -10.6 01/25/2006 02:20:00 3 0.5 4.2 1.5 2.9 0.5 3.8 1.5 2 0.5 3.8 0.4 303 6 309 165 -9.9 0 -9.7 -10.2 01/25/2006 02:30:00 1.4 0.7 3 0.4 1.2 0.8 3 0.4 1.3 0.5 3 0.4 340 22 328 165 -9.6 0.3 -9.1 -10.2 01/25/2006 02:40:00 1.7 0.8 3 0.4 1.6 0.8 3 0.4 1.3 0.7 2.6 0.4 309 20 288 165 -9.4 0 -9.3 -9.7 01/25/2006 02:50:00 2.7 0.4 3.8 1.9 2.6 0.4 3.8 1.9 2.2 0.5 3.4 1.1 312 9 308 165 -9.5 0 -9.3 -9.7 01/25/2006 03:00:00 2.8 0.4 3.8 1.9 2.8 0.4 3.8 1.9 2 0.4 3 1.1 299 5 297 165 -9.6 0 -9.5 -9.7 01/25/2006 03:10:00 2.3 0.4 3.8 1.1 2.2 0.5 3.4 1.1 2.3 0.4 3.4 1.1 322 16 347 165 -9.9 0.1 -9.5 -10.2 01/25/2006 03:20:00 2.3 0.4 3 1.1 2.2 0.4 3 1.1 2.1 0.4 3 0.4 328 17 330 165 -9.8 0 -9.7 -10.2 01/25/2006 03:30:00 2.1 0.4 3 1.1 1.6 0.5 3 0.4 2 0.4 3 1.1 350 11 349 165 -10.1 0 -10 -10.2 01/25/2006 03:40:00 2.6 0.4 3.4 1.5 1.7 0.6 3.8 0.7 2.7 0.3 3.8 1.9 355 9 332 165 -9.9 0 -9.7 -10.2 01/25/2006 03:50:00 3.2 0.3 3.8 2.3 1.8 0.4 3.4 1.1 3.3 0.4 4.2 2.3 3 4 2 165 -10 0 -9.7 -10.2 01/25/2006 04:00:00 3.7 0.4 4.6 2.6 3.2 0.9 4.6 1.1 3.7 0.4 4.9 2.6 348 8 338 165 -9.9 0 -9.7 -10 01/25/2006 04:10:00 3.5 0.3 4.2 2.6 3.4 0.5 4.2 1.5 3.5 0.3 4.6 2.6 335 12 359 165 -9.6 0.1 -9.3 -9.7 01/25/2006 04:20:00 4 0.5 5.3 2.6 3.9 0.5 5.3 2.6 3.9 0.6 5.3 2.6 324 8 309 165 -9.4 0.2 -8.9 -9.7 01/25/2006 04:30:00 4.6 0.4 5.7 3.8 4.5 0.4 5.7 3.8 4.3 0.5 5.3 3.4 317 6 312 165 -8.9 0 -8.7 -9.1 01/25/2006 04:40:00 4.9 0.6 6.5 3.8 4.9 0.6 6.5 3.4 4.5 0.8 6.5 3 316 9 330 165 -9.3 0.1 -8.9 -9.7 01/25/2006 04:50:00 5 0.7 6.5 3.4 4.8 0.7 6.5 3.4 4.8 0.7 6.5 3.4 328 7 319 165 -9.2 0.2 -8.9 -9.7 01/25/2006 05:00:00 4.1 0.6 6.1 2.6 4 0.6 5.7 2.6 3.8 0.5 5.3 3 339 6 335 165 -10.1 0.2 -9.7 -10.2 01/25/2006 05:10:00 5.7 0.6 7.2 3.4 5.6 0.7 7.2 3.4 5.4 0.6 6.8 3.4 341 6 344 165 -10 0 -9.7 -10.2 01/25/2006 05:20:00 5.5 0.5 6.8 3.8 5.1 0.9 6.5 2.3 5.2 0.6 6.5 3.8 346 7 348 165 -10 0 -9.7 -10.2 01/25/2006 05:30:00 5.2 0.5 6.8 3.8 4.5 1 6.8 2.3 5 0.6 6.1 3.8 351 6 345 165 -10.2 0 -10 -10.2 01/25/2006 05:40:00 4.8 0.5 6.1 3 3.8 0.9 5.7 1.5 4.9 0.5 6.1 3.4 353 6 355 165 -9.9 0.1 -9.7 -10.2 01/25/2006 05:50:00 3.9 0.5 5.3 2.6 3.1 0.6 4.9 1.5 3.9 0.5 5.3 2.6 357 10 359 165 -9.7 0 -9.7 -9.7 01/25/2006 06:00:00 3.6 0.7 4.9 1.9 3 0.7 4.6 1.5 3.8 0.6 4.9 2.3 352 8 3 165 -9.6 0.1 -9.3 -10 01/25/2006 06:10:00 3.9 0.4 4.9 3 3.6 0.8 4.9 1.5 3.8 0.4 4.9 2.6 343 10 353 165 -9.6 0.1 -9.3 -9.7 01/25/2006 06:20:00 4.1 0.6 5.7 2.6 4 0.6 5.3 2.6 3.9 0.5 5.3 2.6 335 9 330 165 -9.8 0 -9.7 -10 01/25/2006 06:30:00 4.8 0.4 6.1 3.8 4.7 0.4 6.1 3.8 4.8 0.4 6.1 3.4 332 8 328 165 -9.6 0 -9.3 -10 01/25/2006 06:40:00 2.9 1.1 5.7 0.7 2.6 1.1 4.9 0.4 2.7 1.1 5.7 0.7 336 18 358 165 -9.9 0 -9.7 -10 01/25/2006 06:50:00 2.4 0.5 4.2 1.5 1.9 0.6 3.4 0.7 2.2 0.6 3.8 0.7 356 22 357 165 -10.2 0.1 -10 -10.4 01/25/2006 07:00:00 2.2 0.5 3.8 1.1 1.7 0.6 3.4 0.4 2.2 0.6 4.2 1.1 355 13 10 165 -10.2 0.1 -9.7 -10.4 01/25/2006 07:10:00 3.7 0.8 5.3 1.1 3.2 1.1 5.3 0.7 3.7 0.8 5.3 1.5 356 13 347 165 -9.9 0 -9.7 -10 01/25/2006 07:20:00 5 1.2 8 3 4.4 1.7 8.4 1.1 5.1 1.2 7.6 3 356 15 340 165 -9.9 0 -9.7 -10 01/25/2006 07:30:00 4.6 1 7.6 3.4 4.5 1 8 2.3 4.7 0.9 7.6 3.4 338 9 338 165 -9.7 0 -9.5 -10 01/25/2006 07:40:00 4.4 1 6.8 2.6 4.3 1 6.8 1.9 4.4 0.9 7.2 2.6 338 11 334 165 -9.6 0.1 -9.3 -9.7 01/25/2006 07:50:00 4.3 0.8 6.5 2.3 4.2 0.8 6.1 1.9 4.2 0.8 6.5 2.6 334 15 4 165 -9.2 0 -8.9 -9.3 01/25/2006 08:00:00 4.3 0.9 6.8 2.3 4.1 0.9 6.1 2.3 4.3 1 6.8 1.9 333 15 1 165 -9.1 0 -8.9 -9.3 01/25/2006 08:10:00 3.8 0.7 6.5 2.6 3.7 0.8 6.1 2.6 3.5 0.7 6.1 1.9 322 8 322 165 -9.7 0.3 -9.1 -10.2 01/25/2006 08:20:00 5.5 0.9 7.6 3.4 5.2 0.9 7.2 3 5.4 1 7.6 3.4 338 16 354 165 -9.7 0.2 -9.3 -10.2 01/25/2006 08:30:00 4.3 0.7 6.1 2.6 4.1 0.9 6.1 1.5 4.3 0.7 6.1 2.6 335 13 328 165 -9.5 0.1 -9.3 -9.7 01/25/2006 08:40:00 3.7 0.6 5.7 2.3 3.6 0.6 6.1 2.3 3.4 0.7 5.3 1.9 321 12 321 165 -9.4 0 -9.3 -9.7 01/25/2006 08:50:00 2 1.2 5.7 0.4 1.8 1.3 5.7 0.4 1.7 1.2 6.5 0.4 308 20 313 165 -9.3 0 -9.1 -9.3 01/25/2006 09:00:00 3.2 0.7 5.3 1.5 3.1 0.7 4.9 1.5 2.9 0.8 4.6 0.7 315 22 331 165 -9.1 0 -8.9 -9.3 01/25/2006 09:10:00 4.6 1.1 7.2 2.3 4.4 1.1 7.2 1.9 4.5 1.1 7.2 2.3 330 13 322 165 -9.2 0 -9.1 -9.3 01/25/2006 09:20:00 4.6 0.9 6.5 2.6 4.5 1 6.5 2.3 4.2 0.9 6.5 1.9 314 22 335 165 -9.1 0 -8.9 -9.3 01/25/2006 09:30:00 5.6 0.9 8 3.4 5.6 0.9 8 3.4 5.2 1.1 8.4 2.3 317 16 338 165 -9 0.1 -8.7 -9.1 01/25/2006 09:40:00 5.5 1 7.6 3 5.4 1 8 3 4.9 0.8 7.2 3 320 15 299 165 -9.2 0 -9.1 -9.5 01/25/2006 09:50:00 3.7 0.5 5.3 2.6 3.3 0.6 4.9 1.1 3.6 0.6 5.3 2.6 343 11 3 165 -9.5 0 -9.3 -9.7 01/25/2006 10:00:00 4.4 0.8 6.8 2.6 4 1 6.8 1.5 4.1 0.9 7.2 1.5 333 17 327 165 -9.1 0 -8.9 -9.3 01/25/2006 10:10:00 3.4 2.1 8.8 0.7 3.3 2.2 8 1.1 3.2 1.9 8 1.1 332 17 338 165 -9 0 -8.9 -9.1 01/25/2006 10:20:00 5.6 1.1 8 3 5 1.2 8 2.6 5.5 1 8 3 346 11 327 165 -8.7 0.1 -8.5 -9.1 01/25/2006 10:30:00 4 1.2 6.8 1.1 3.9 1.3 7.2 1.1 4.1 1.3 8 1.1 335 19 342 165 -8.4 0 -8.1 -8.5 01/25/2006 10:40:00 2.8 0.7 4.6 1.5 2.1 0.7 4.6 0.7 2.8 0.7 4.6 1.1 350 15 0 165 -8.1 0 -8.1 -8.5 01/25/2006 10:50:00 4.4 0.9 6.8 2.6 4.2 1 6.8 1.9 4.2 0.9 6.5 2.6 334 14 352 165 -8 0 -7.9 -8.1 01/25/2006 11:00:00 4.7 0.9 7.2 1.9 4.5 1 7.2 1.9 4.5 1.1 6.5 1.5 327 18 343 165 -7.8 0.2 -7.2 -8.1 01/25/2006 11:10:00 4.6 0.8 6.8 2.3 4.5 0.8 6.5 2.3 4.5 0.8 6.8 2.6 326 13 344 165 -7.1 0.2 -6.6 -7.6 01/25/2006 11:20:00 5.3 1 8.4 3 5.1 1.1 8 2.6 4.9 1.1 8 2.3 324 15 315 165 -6.6 0.1 -6.4 -7 01/25/2006 11:30:00 5.8 1.2 8.8 2.6 5.7 1.1 8.8 2.6 5.1 1.3 8.4 1.9 312 16 322 165 -7.2 0.2 -6.8 -7.6 01/25/2006 11:40:00 7.2 1.1 10.7 4.6 7.1 1.1 10.3 4.6 5.9 1.2 9.1 3 302 10 304 165 -7.2 0.2 -6.8 -7.6 01/25/2006 11:50:00 6.6 1.5 9.9 3.4 6.6 1.5 9.9 3.8 6 1.7 11.1 2.6 314 11 322 165 -7.4 0.2 -6.8 -7.9 01/25/2006 12:00:00 6.1 0.9 8.4 3 6.1 0.9 8.4 3.4 5.4 0.8 8.4 3.4 308 9 296 165 -7.1 0 -6.8 -7.2 01/25/2006 12:10:00 5.5 1.1 8.8 3.4 5.6 1.1 8.4 3 5.2 1.2 8 2.3 316 10 313 165 -6.9 0.2 -6.6 -7.4 01/25/2006 12:20:00 5 1.2 7.6 1.9 5 1.1 7.6 2.3 4.4 1 6.8 1.9 310 13 293 165 -6.7 0.2 -6.1 -6.8 01/25/2006 12:30:00 5.8 0.8 7.6 3.8 5.9 0.8 8.4 3.8 5 0.9 8 3.4 306 13 290 165 -7.1 0.3 -6.1 -7.4 01/25/2006 12:40:00 5.7 1.3 10.7 2.6 5.8 1.3 10.7 2.6 5.2 1.1 9.5 1.9 311 12 291 165 -7 0.1 -6.6 -7.2 01/25/2006 12:50:00 6.2 0.9 8.8 3.8 6.3 0.8 8.8 3.8 5.2 1 8 3 302 10 300 165 -7.2 0.2 -6.8 -7.4 01/25/2006 13:00:00 6.8 0.9 9.5 4.9 6.8 0.8 9.1 4.9 5.8 1 8.8 3.4 306 11 309 165 -7.4 0 -7.2 -7.6 01/25/2006 13:10:00 6.5 1.1 9.1 3.4 6.4 1.1 9.1 3.8 5.7 1.2 9.5 3 308 12 287 165 -7.4 0.1 -7.2 -7.6 01/25/2006 13:20:00 7.4 0.9 9.1 4.9 7.4 0.9 9.1 4.9 6.5 1.2 9.5 3.4 298 9 299 165 -7.6 0.2 -7 -7.9 01/25/2006 13:30:00 6 1 8.4 3.8 5.9 1 8 3.8 5.2 0.9 7.6 2.3 307 12 298 165 -6.7 0.3 -5.9 -7 01/25/2006 13:40:00 6.5 1.1 8.8 3.8 6.4 1 8.8 3.8 5.8 1.2 8.4 3.4 313 17 324 165 -6.9 0.3 -6.1 -7.2 01/25/2006 13:50:00 7.1 1 9.5 3.4 7 1 9.1 3.4 6.2 1.2 9.1 3.4 313 10 322 165 -6.8 0.1 -6.6 -7.2 01/25/2006 14:00:00 6.8 0.9 9.5 4.2 6.6 0.9 9.5 4.2 6.2 0.9 8.4 3.8 321 17 314 165 -6.6 0.1 -6.1 -6.8 01/25/2006 14:10:00 7.7 0.8 9.9 5.7 7.6 0.8 9.9 5.7 7.4 0.9 9.5 4.9 326 11 338 165 -6.5 0 -6.1 -6.8 01/25/2006 14:20:00 8.2 1.2 12.2 5.7 8.1 1.1 11.8 5.7 7.3 1 10.3 3.8 315 13 315 165 -6.8 0.1 -6.6 -7.2 01/25/2006 14:30:00 8.6 0.8 11.5 6.5 8.4 0.8 11.1 6.1 8 1 11.1 5.3 317 9 320 165 -7 0.2 -6.6 -7.2 01/25/2006 14:40:00 9 0.9 11.1 6.5 8.8 1 11.5 4.9 8.9 0.9 11.5 6.5 334 13 334 165 -6.9 0 -6.8 -7 01/25/2006 14:50:00 9.1 1 11.8 6.1 9 1 11.8 6.1 8.6 0.9 11.8 6.1 315 9 315 165 -7.1 0 -6.8 -7.2 01/25/2006 15:00:00 8.8 0.9 10.7 6.5 8.7 0.9 10.7 6.5 8.6 0.9 11.1 5.7 328 12 319 165 -7 0 -6.8 -7.2 01/25/2006 15:10:00 8.9 1.1 11.8 6.5 8.8 1 11.8 5.7 8.2 1 11.5 5.3 317 11 326 165 -6.9 0 -6.8 -7.2 01/25/2006 15:20:00 8.7 1 11.5 6.5 8.6 1 10.7 6.5 8.2 1.1 10.7 5.3 316 8 305 165 -7.1 0 -6.8 -7.2 01/25/2006 15:30:00 10.1 1.5 14.9 7.2 9.9 1.5 15.3 6.5 9.4 1.8 14.9 5.7 322 17 344 165 -7.2 0.1 -6.8 -7.4 01/25/2006 15:40:00 9.4 1.5 13.7 6.1 9 1.4 13.3 5.7 9.1 1.5 14.1 5.3 334 16 357 165 -7.3 0.1 -7.2 -7.4 01/25/2006 15:50:00 10.8 1.5 14.1 7.6 10 2.1 15.3 4.9 10.4 1.7 14.1 6.1 342 13 7 165 -7.4 0 -7.2 -7.4 01/25/2006 16:00:00 11.4 1.7 15.6 6.8 11.3 1.8 16.8 6.8 11.2 1.8 16.1 7.6 338 13 347 165 -7.4 0 -7.2 -7.4 01/25/2006 16:10:00 11.1 1.2 14.5 8.8 11 1.3 14.5 8 10.8 1.3 14.9 7.6 334 11 345 165 -7.5 0 -7.4 -7.6 01/25/2006 16:20:00 10.1 1 12.6 7.6 10 1 12.6 7.2 9.9 1 13.3 6.5 326 13 1 165 -7.6 0 -7.6 -7.6 01/25/2006 16:30:00 10.4 1.2 13.7 6.8 10.2 1.3 14.1 6.5 10.1 1.1 14.1 6.8 337 10 339 165 -7.8 0 -7.6 -8.1 01/25/2006 16:40:00 9 0.9 11.8 5.7 8.8 1 11.5 4.6 8.8 1 11.5 6.5 329 13 353 165 -7.9 0 -7.6 -8.1 01/25/2006 16:50:00 9.3 1 13 6.8 9.1 1 13.3 6.5 9 1 12.6 6.8 328 10 344 165 -8.1 0 -8.1 -8.5 01/25/2006 17:00:00 10 1.2 13.3 7.6 9.9 1.2 13.7 7.6 9.5 1.3 13.3 6.5 322 12 332 165 -8.5 0.1 -8.3 -8.7 01/25/2006 17:10:00 9.9 1.2 12.6 6.5 9.8 1.1 12.2 6.8 9.9 1.2 13 6.5 330 11 354 165 -8.4 0 -8.3 -8.5 01/25/2006 17:20:00 9.3 1.5 14.9 6.1 9.1 1.5 14.9 5.3 8.9 1.6 14.1 5.7 326 16 339 165 -8.5 0 -8.3 -8.5 01/25/2006 17:30:00 8.5 0.9 11.5 5.7 8.4 1 11.1 4.9 8 1 10.7 4.9 316 10 307 165 -8.7 0 -8.5 -8.9 01/25/2006 17:40:00 9 1.2 12.2 6.1 9 1.2 12.2 6.1 8.5 1.2 11.8 5.7 318 11 305 165 -8.6 0.1 -8.3 -9.1 01/25/2006 17:50:00 9.7 1.1 12.2 6.5 9.6 1.1 12.2 6.5 8.5 1.3 12.2 4.9 312 10 310 165 -8.5 0.1 -8.3 -8.5 01/25/2006 18:00:00 9.2 1.2 13 6.1 9.2 1.2 13.3 6.1 8.3 1.3 12.6 4.9 311 7 321 165 -8.5 0.1 -8.3 -8.7 01/25/2006 18:10:00 8.6 1.4 12.2 5.3 8.5 1.4 12.2 4.9 8.1 1.5 12.2 4.9 319 13 321 165 -8.5 0.1 -8.3 -8.7 01/25/2006 18:20:00 8.2 1 10.7 5.3 8.2 1 11.1 5.3 7.4 1.2 11.1 4.2 310 10 307 165 -8.5 0.1 -8.3 -8.7 01/25/2006 18:30:00 8 1.2 11.5 4.9 7.7 1.3 11.8 4.6 7.4 1.4 11.1 4.2 323 18 344 165 -8.6 0 -8.5 -8.7 01/25/2006 18:40:00 9.2 1.4 14.1 6.1 8.6 1.7 14.1 4.9 9.1 1.3 12.6 6.1 340 17 338 165 -8.6 0 -8.3 -8.7 01/25/2006 18:50:00 9.2 1.9 12.6 4.2 9.1 1.8 12.6 4.2 8.1 1.7 13 3.8 313 16 293 165 -8.3 0 -8.1 -8.5 01/25/2006 19:00:00 9.7 1.2 13 6.8 9.5 1.1 13 6.5 9.1 1.2 11.8 5.7 320 11 305 165 -8.5 0 -8.3 -8.7 01/25/2006 19:10:00 10.1 1.1 13 7.2 10 1.1 13 6.8 8.7 1.1 11.8 5.7 310 8 302 165 -8.6 0 -8.5 -8.7 01/25/2006 19:20:00 8.7 1.1 11.5 5.3 8.5 1.1 11.5 5.3 7.7 1.2 10.7 5.3 315 8 320 165 -8.6 0 -8.5 -8.7 01/25/2006 19:30:00 10.1 1.1 13.7 7.6 10 1.1 13.3 7.6 9.4 1.2 12.2 5.7 317 6 316 165 -8.5 0 -8.1 -8.7 01/25/2006 19:40:00 10.4 0.8 13 8.4 10.3 0.8 12.6 8 9.5 0.8 12.2 7.2 314 6 323 165 -8.3 0 -8.1 -8.5 01/25/2006 19:50:00 12.2 1.2 15.6 9.1 12.1 1.2 15.6 8.4 11.3 1.3 15.3 7.2 314 5 316 165 -8.2 0 -8.1 -8.5 01/25/2006 20:00:00 12.3 1.1 16.1 9.1 12.2 1.1 16.1 9.5 11.2 1 14.1 8.4 313 6 310 165 -8.2 0 -8.1 -8.3 01/25/2006 20:10:00 13.2 1 16.1 11.1 13.1 1 16.1 10.7 12.5 0.9 14.5 9.5 315 5 312 165 -8.1 0 -8.1 -8.3 01/25/2006 20:20:00 11.9 1.2 14.9 8.8 11.8 1.2 14.9 8.4 11.4 1.4 15.3 7.6 320 6 316 165 -8.2 0 -8.1 -8.5 01/25/2006 20:30:00 11.3 1.2 13.7 7.6 11.1 1.2 13.7 7.6 10.4 1.3 13 6.5 316 6 315 165 -8.2 0 -8.1 -8.3 01/25/2006 20:40:00 10.3 1.1 13.3 7.6 10.2 1.1 13.3 7.6 9.4 1.2 13.3 6.1 314 6 314 165 -8.2 0 -8.1 -8.3 01/25/2006 20:50:00 10.6 1.3 13.3 6.8 10.5 1.3 13 6.8 9.6 1.3 12.6 6.1 313 6 301 165 -8.1 0 -8.1 -8.1 01/25/2006 21:00:00 9.9 1.1 12.2 6.5 9.8 1.1 11.8 6.1 9.1 1.2 11.5 4.9 316 7 309 165 -8 0 -8.1 -8.1 01/25/2006 21:10:00 10.1 1 12.6 7.2 10 1 13 7.2 9.4 1.1 12.2 6.5 315 6 317 165 -8 0 -8.1 -8.1 01/25/2006 21:20:00 10.1 1.2 13.3 6.8 10 1.2 13.3 6.8 9.6 1.2 12.6 5.7 320 9 326 165 -8 0 -7.6 -8.1 01/25/2006 21:30:00 9.9 1.3 13.3 6.8 9.8 1.3 13 6.8 9.2 1.4 12.6 4.2 317 9 319 165 -8 0 -7.6 -8.1 01/25/2006 21:40:00 8.4 1.1 11.1 4.9 8.3 1.1 10.7 4.9 7.2 1.3 10.7 4.2 310 8 306 165 -8.1 0 -7.9 -8.3 01/25/2006 21:50:00 9.4 0.9 11.5 6.1 9.2 0.8 11.1 6.5 7.9 1.1 11.1 4.6 308 6 307 165 -8 0 -7.9 -8.3 01/25/2006 22:00:00 8 1.1 11.1 4.2 7.9 1 10.7 4.6 6.8 1.2 11.1 4.2 309 7 319 165 -8 0 -7.9 -8.1 01/25/2006 22:10:00 6.9 1.3 9.5 3.8 6.9 1.3 9.5 4.2 6.1 1.3 9.1 3.4 310 7 312 165 -8.2 0 -8.1 -8.3 01/25/2006 22:20:00 5.9 1 8 3.4 5.9 1 8 3.4 4.9 1 7.2 2.6 315 8 301 165 -8.5 0 -8.3 -8.5 01/25/2006 22:30:00 6.1 0.8 7.6 3.8 6.1 0.8 7.6 4.2 5 0.9 7.2 2.6 311 8 319 165 -8.6 0 -8.5 -8.7 01/25/2006 22:40:00 6.6 0.6 8 4.6 6.5 0.6 8 4.6 5.7 0.8 7.6 3.4 310 5 310 165 -8.4 0 -8.1 -8.7 01/25/2006 22:50:00 8 0.5 9.1 6.5 7.9 0.5 8.8 6.5 7.1 0.6 8.4 4.9 311 3 309 165 -8.1 0.1 -8.1 -8.3 01/25/2006 23:00:00 8.1 0.6 9.5 5.7 8 0.6 9.1 6.1 7.4 0.6 9.1 5.3 312 4 313 165 -8 0 -8.1 -8.1 01/25/2006 23:10:00 9.1 0.6 10.3 7.2 8.9 0.5 10.3 6.8 8.5 0.6 10.3 6.5 314 3 314 165 -8 0 -7.9 -8.1 01/25/2006 23:20:00 8.7 0.6 9.9 6.8 8.5 0.6 9.9 6.5 8.5 0.6 9.5 6.8 318 3 314 165 -7.9 0 -7.6 -8.1 01/25/2006 23:30:00 8.2 0.7 9.9 6.5 8 0.7 9.9 6.1 7.5 0.7 9.9 6.1 315 5 318 165 -7.8 0.1 -7.4 -8.1 01/25/2006 23:40:00 8.6 0.5 9.9 7.2 8.4 0.5 9.9 7.2 8.2 0.6 10.3 6.5 318 4 311 165 -7.6 0 -7.4 -7.6 01/25/2006 23:50:00 9 1 11.5 6.8 8.8 1 11.5 6.8 8.5 1 11.8 6.1 317 5 310 165 -7.4 0 -7.2 -7.4 01/26/2006 00:00:00 7.9 0.7 9.5 4.9 7.8 0.7 9.1 5.3 7.7 0.8 9.5 4.9 322 6 326 165 -7.4 0 -7.2 -7.4 01/26/2006 00:10:00 7.4 0.7 9.1 5.7 7.2 0.7 8.8 5.7 7.3 0.7 8.8 5.3 320 4 313 165 -7.4 0 -7.2 -7.4 01/26/2006 00:20:00 6.2 0.6 7.6 4.6 6.1 0.6 7.2 4.9 6.1 0.6 7.6 4.9 319 4 318 165 -7.5 0 -7.2 -7.4 01/26/2006 00:30:00 6.2 0.4 7.2 4.9 6 0.4 6.8 4.6 6.1 0.4 7.2 4.6 318 3 320 165 -7.5 0 -7.2 -7.6 01/26/2006 00:40:00 7.7 0.9 10.7 6.1 7.5 0.9 10.7 6.1 7.5 0.9 11.1 6.1 317 3 318 165 -7.4 0 -7.2 -7.4 01/26/2006 00:50:00 9.5 0.6 10.7 8 9.3 0.6 10.7 7.6 9.1 0.7 10.3 6.8 317 4 319 165 -7.4 0.1 -7.2 -7.4 01/26/2006 01:00:00 9.7 0.6 11.1 8 9.6 0.6 11.1 7.6 9.5 0.6 11.8 8 317 5 314 165 -7.3 0 -7.2 -7.4 01/26/2006 01:10:00 9.5 0.7 11.1 8 9.3 0.7 10.7 7.6 8.7 0.9 10.7 6.1 311 4 313 165 -7.4 0 -7.2 -7.4 01/26/2006 01:20:00 10 0.6 11.8 8.4 9.9 0.6 11.8 8 9.8 0.6 11.5 8 317 4 325 165 -7.4 0 -7.2 -7.4 01/26/2006 01:30:00 9.8 0.7 11.5 8.4 9.6 0.7 11.1 8 9.2 0.9 11.8 6.5 315 6 307 165 -7.2 0 -7 -7.4 01/26/2006 01:40:00 9.7 0.9 12.6 8 9.6 0.9 12.2 8 8.8 1 11.5 5.7 312 5 308 165 -7.2 0 -7 -7.2 01/26/2006 01:50:00 9.7 0.8 12.2 6.8 9.6 0.8 12.2 6.8 8.1 1 10.3 5.3 308 5 302 165 -7.2 0 -7 -7.2 01/26/2006 02:00:00 9.2 0.9 11.5 6.8 9.1 0.8 11.1 6.5 7.7 1.3 10.7 4.6 308 5 314 165 -7.2 0 -7 -7.2 01/26/2006 02:10:00 8.3 0.9 10.3 5.7 8.2 0.9 9.9 5.7 6.2 0.8 8.8 4.2 304 6 305 165 -7.2 0 -7.2 -7.4 01/26/2006 02:20:00 6.9 1 10.3 4.6 6.8 1 10.7 4.6 6 1.2 8.8 3.8 314 14 287 165 -7.1 0.1 -6.8 -7.2 01/26/2006 02:30:00 7.7 1.2 10.7 5.3 7.7 1.1 10.7 5.3 6 1.1 9.1 3.8 301 7 293 165 -7.2 0 -6.8 -7.2 01/26/2006 02:40:00 8.4 0.9 10.3 5.7 8.3 0.9 10.3 5.7 6.3 0.8 8.8 4.9 304 6 299 165 -7.2 0 -7 -7.2 01/26/2006 02:50:00 8 1.2 11.5 5.3 7.9 1.2 11.5 4.9 6.7 1.1 10.3 4.2 304 10 300 165 -7.2 0 -7 -7.4 01/26/2006 03:00:00 8.8 1 11.1 6.5 8.7 1 11.1 6.1 7.4 1.1 9.9 4.6 309 6 307 165 -7.2 0 -7 -7.2 01/26/2006 03:10:00 7.4 0.8 9.1 4.6 7.3 0.8 9.1 4.6 6.3 0.9 8.8 3.8 309 5 308 165 -7.2 0 -7 -7.4 01/26/2006 03:20:00 7.4 1.2 11.1 4.9 7.4 1.2 10.3 4.9 6.6 1.1 9.1 3.8 312 7 302 165 -7.2 0 -7 -7.2 01/26/2006 03:30:00 7.4 1.2 10.3 4.6 7.3 1.2 9.5 4.9 6.4 1.1 9.1 3.8 310 7 315 165 -7.2 0 -7 -7.2 01/26/2006 03:40:00 7.1 0.6 8.4 5.7 6.9 0.6 8.4 5.3 6.5 0.8 8.8 4.6 313 6 317 165 -7.2 0 -7 -7.2 01/26/2006 03:50:00 7.4 0.7 9.1 4.9 7.2 0.8 9.1 4.6 6.6 0.8 9.1 4.2 311 5 310 165 -7.2 0 -7 -7.2 01/26/2006 04:00:00 7.7 0.7 9.9 6.1 7.6 0.7 9.9 5.7 7.5 0.8 9.9 5.3 319 6 322 165 -7.2 0 -7 -7.2 01/26/2006 04:10:00 7.2 0.8 9.5 4.9 7.1 0.8 9.1 4.6 7 0.8 8.4 4.2 321 9 321 165 -7.2 0 -7 -7.2 01/26/2006 04:20:00 7.7 0.7 9.9 6.1 7.6 0.7 9.9 5.7 7 0.9 9.9 4.9 312 5 310 165 -7.2 0 -7.2 -7.4 01/26/2006 04:30:00 8 0.8 9.9 6.1 7.9 0.8 9.9 5.7 7.3 1 9.5 4.2 312 6 316 165 -7.3 0 -7.2 -7.4 01/26/2006 04:40:00 7.4 0.9 9.5 4.6 7.2 0.9 9.1 4.6 7.1 0.8 9.5 4.9 318 7 312 165 -7.4 0 -7.2 -7.4 01/26/2006 04:50:00 6.1 0.7 8 4.6 5.9 0.7 7.6 4.2 5.9 0.7 7.6 3.8 320 7 310 165 -7.5 0 -7.2 -7.6 01/26/2006 05:00:00 7.2 0.8 9.1 5.3 7.1 0.7 8.8 5.3 6.7 0.8 9.1 4.6 315 6 314 165 -7.6 0 -7.4 -7.6 01/26/2006 05:10:00 7.1 0.8 8.8 5.3 7 0.7 8.8 5.3 6.3 0.9 8.4 4.2 311 6 306 165 -7.8 0.1 -7.6 -8.1 01/26/2006 05:20:00 7.2 0.6 8.8 5.3 7 0.6 8.4 5.7 6.8 0.6 8.8 4.9 317 5 309 165 -7.9 0 -7.6 -8.1 01/26/2006 05:30:00 8.3 0.9 10.7 5.3 8.2 0.9 10.3 5.7 7.4 1 9.9 4.9 313 6 319 165 -8 0 -7.9 -8.1 01/26/2006 05:40:00 9.4 0.9 12.2 6.8 9.3 0.9 12.2 6.8 8.8 1 11.5 6.5 318 9 340 165 -8 0 -7.9 -8.1 01/26/2006 05:50:00 9.1 0.7 10.7 7.2 9 0.7 10.7 7.2 8.9 0.8 11.1 6.5 321 5 322 165 -8 0 -7.6 -8.1 01/26/2006 06:00:00 8.3 0.8 10.3 6.1 8.1 0.8 9.9 6.1 8 0.8 9.9 5.7 322 7 313 165 -8.1 0 -8.1 -8.3 01/26/2006 06:10:00 8.2 1.1 11.8 5.7 8.1 1 11.1 5.7 7.5 1.2 9.9 3 318 7 315 165 -8.2 0 -8.1 -8.3 01/26/2006 06:20:00 6.5 1 8.8 3.4 6.5 1 8.8 3.4 5.5 1.4 8 1.5 311 10 304 165 -8.5 0.1 -8.1 -8.7 01/26/2006 06:30:00 6.2 1 8.8 3.4 6.1 1 9.1 3.4 5.2 1.3 7.6 0.7 311 9 318 165 -8.8 0 -8.5 -8.9 01/26/2006 06:40:00 5.4 1.2 8.4 2.3 5.4 1.2 8.4 2.3 4.4 1.2 6.8 1.1 305 12 297 165 -8.9 0 -8.7 -9.1 01/26/2006 06:50:00 7.2 1 9.5 4.2 7.1 1 9.1 4.2 5.8 1 8 3.4 303 9 297 165 -8.8 0 -8.5 -9.1 01/26/2006 07:00:00 5.9 0.6 8 4.2 5.9 0.7 7.6 3.8 4.5 0.8 6.5 2.3 302 6 309 165 -8.9 0.1 -8.7 -9.1 01/26/2006 07:10:00 6.9 0.7 8.4 4.9 6.8 0.7 8.4 4.9 5.2 0.7 7.6 3.4 301 5 302 165 -9 0 -8.9 -9.1 01/26/2006 07:20:00 6.9 0.9 8.8 4.2 6.8 0.8 8.8 4.6 5.7 0.9 8.4 3.8 290 9 297 165 -8.9 0.1 -8.5 -9.1 01/26/2006 07:30:00 6.4 1.4 9.5 3.4 6.7 1.1 9.1 4.2 5.8 1.2 8.8 3 280 11 289 165 -8.7 0 -8.5 -8.9 01/26/2006 07:40:00 6.2 1.1 8.8 2.6 6.3 1 8.8 3.8 5 1.1 8 2.6 283 10 297 165 -8.9 0 -8.7 -9.1 01/26/2006 07:50:00 6.9 0.8 8.8 4.9 6.8 0.7 8.4 4.9 5.5 0.8 7.2 3 293 6 292 165 -9 0 -8.9 -9.1 01/26/2006 08:00:00 5.6 1 8 1.9 5.5 1 8 1.9 4.1 1.2 6.8 1.1 296 9 303 165 -9.1 0 -8.9 -9.1 01/26/2006 08:10:00 5.8 0.9 8 3.4 5.8 0.8 8 3.8 4.2 0.9 7.2 1.9 295 9 289 165 -9.1 0 -8.9 -9.3 01/26/2006 08:20:00 3.7 1.4 6.8 0.4 3.7 1.4 6.8 0.7 2.7 1.2 6.1 0.4 281 29 294 165 -9 0 -8.9 -9.1 01/26/2006 08:30:00 5.2 1.2 8 2.6 5.1 1.3 8 2.3 4 1.3 7.6 0.7 303 12 307 165 -9.2 0 -8.9 -9.3 01/26/2006 08:40:00 2.7 1.3 5.7 0.4 2.7 1.2 5.3 0.4 1.7 1.1 4.2 0.4 287 41 307 165 -9.4 0.1 -9.1 -9.7 01/26/2006 08:50:00 1.8 1.1 4.6 0.4 2 1.1 4.6 0.4 1.4 0.8 3.4 0.4 233 51 213 165 -9.2 0.1 -8.9 -9.7 01/26/2006 09:00:00 2.6 1.2 5.7 0.4 2.8 1.3 6.1 0.4 2.6 1.1 4.9 0.4 315 98 278 165 -9 0 -8.9 -9.1 01/26/2006 09:10:00 4.8 2 9.5 1.1 5 2 9.5 1.1 4.2 1.7 8.8 0.7 271 49 289 165 -8.8 0 -8.5 -8.9 01/26/2006 09:20:00 2.1 1 4.2 0.4 2.2 1 4.6 0.4 2.1 0.9 4.2 0.4 207 49 287 165 -8.6 0.1 -8.5 -8.9 01/26/2006 09:30:00 2.6 1 4.9 0.4 3 1.1 5.7 0.4 2.5 1.2 5.7 0.4 311 90 281 165 -8.4 0 -8.1 -8.5 01/26/2006 09:40:00 4.4 1 6.8 1.5 4.7 0.9 6.8 2.3 4.3 0.9 6.8 2.3 278 12 285 165 -8.3 0 -8.1 -8.5 01/26/2006 09:50:00 5.5 0.6 7.2 3.8 5.5 0.6 7.2 4.2 4.3 0.8 6.8 2.6 290 7 294 165 -8.3 0 -8.1 -8.5 01/26/2006 10:00:00 6.4 0.7 8.4 4.6 6.3 0.7 8 4.6 4.8 0.8 7.2 3 296 5 295 165 -8.1 0.1 -7.9 -8.5 01/26/2006 10:10:00 6.8 0.5 8 5.3 6.7 0.5 8 5.3 5.2 0.7 6.8 3.4 301 5 301 165 -7.9 0 -7.6 -8.1 01/26/2006 10:20:00 8.4 0.8 10.3 6.5 8.3 0.8 10.3 6.5 6.2 0.9 8.8 4.6 302 5 303 165 -7.6 0.1 -7.4 -8.1 01/26/2006 10:30:00 7.2 1.3 10.3 4.6 7.1 1.3 10.7 4.6 6.1 0.9 8.4 3.8 311 8 304 165 -7.2 0.2 -6.8 -7.6 01/26/2006 10:40:00 5.6 0.8 8 3.8 5.5 0.7 8 3.8 5.1 0.8 7.2 3 315 10 310 165 -6.8 0 -6.6 -7 01/26/2006 10:50:00 5 1.1 7.6 2.3 5.1 1.1 8 2.3 4.1 0.8 6.5 1.9 307 13 306 165 -6.7 0.3 -6.1 -7 01/26/2006 11:00:00 4.8 1.3 8 1.9 4.9 1.3 8 1.9 4.1 1.1 7.2 1.1 305 11 300 165 -6.2 0.1 -5.9 -6.6 01/26/2006 11:10:00 5.3 1 7.6 2.6 5.4 1 7.6 2.6 4.6 1.1 7.2 1.9 305 9 295 165 -6.4 0.1 -5.9 -6.6 01/26/2006 11:20:00 4 0.7 6.1 1.5 4.1 0.7 5.7 1.5 3.3 0.8 5.3 0.7 303 11 296 165 -5.5 0.1 -5.3 -6.1 01/26/2006 11:30:00 3.6 0.8 6.1 1.9 3.8 0.7 6.1 2.3 3 0.7 4.9 1.1 303 10 305 165 -5.6 0.2 -5 -5.9 01/26/2006 11:40:00 3.5 0.8 8 1.9 3.7 0.7 8 1.9 3.3 0.9 7.6 1.5 317 12 310 165 -4.9 0.2 -4.6 -5.3 01/26/2006 11:50:00 4.3 1.1 6.5 2.3 4.5 1 6.5 2.3 3.7 0.9 6.1 1.5 301 9 292 165 -5.8 0.4 -5 -6.6 01/26/2006 12:00:00 4.9 0.8 7.6 3.4 5 0.8 7.6 3.4 4.5 0.7 6.8 3 307 8 302 165 -6 0.2 -5.7 -6.6 01/26/2006 12:10:00 5.2 0.8 6.8 3.4 5.3 0.7 7.2 3.4 4.9 0.9 6.8 3 312 12 305 165 -6.1 0 -5.9 -6.4 01/26/2006 12:20:00 6.1 1 8 3.8 6.1 0.9 8 3.8 5.8 1 8.4 3 315 10 318 165 -6.2 0 -6.1 -6.6 01/26/2006 12:30:00 7.8 1.3 11.1 4.6 7.7 1.4 10.7 4.2 7.6 1.3 10.7 4.6 318 9 320 165 -6.3 0.1 -6.1 -6.6 01/26/2006 12:40:00 9.1 0.8 11.1 6.8 9.1 0.8 10.7 6.8 8.8 0.9 11.1 5.7 313 5 318 165 -6.6 0 -6.6 -6.6 01/26/2006 12:50:00 9 0.6 10.3 7.2 8.9 0.6 10.3 6.8 6.7 0.7 9.5 4.9 304 4 298 165 -6.6 0 -6.4 -6.6 01/26/2006 13:00:00 7.9 0.9 9.5 5.3 7.8 0.9 9.5 5.3 6.2 1 8.8 4.2 305 5 307 165 -6.5 0 -6.1 -6.8 01/26/2006 13:10:00 8.1 0.7 9.9 6.1 8.1 0.7 9.9 5.7 6.2 0.8 8.4 4.2 304 5 300 165 -6.4 0 -6.1 -6.6 01/26/2006 13:20:00 8.3 0.8 9.9 6.1 8.3 0.8 10.3 6.1 7.1 1 9.9 4.6 307 5 307 165 -6.5 0 -6.4 -6.6 01/26/2006 13:30:00 9.6 0.7 11.1 7.6 9.6 0.7 10.7 7.6 8.5 1 10.3 6.1 310 5 313 165 -6.6 0 -6.4 -6.8 01/26/2006 13:40:00 9.4 0.7 10.7 7.2 9.3 0.7 10.7 6.8 8.4 1 10.3 5.7 311 5 307 165 -6.5 0 -6.4 -6.6 01/26/2006 13:50:00 8 0.8 9.9 5.7 8 0.7 9.5 5.7 8 0.8 9.9 5.3 315 6 313 165 -6.4 0 -6.1 -6.6 01/26/2006 14:00:00 8.3 0.7 9.5 6.5 8.3 0.7 9.5 6.1 7.6 0.8 9.1 4.9 312 4 308 165 -6.5 0 -6.4 -6.8 01/26/2006 14:10:00 8.1 0.6 9.5 6.1 8 0.6 9.1 6.1 7.9 0.6 9.9 5.3 315 4 313 165 -6.6 0 -6.6 -6.8 01/26/2006 14:20:00 7.7 0.6 9.1 5.7 7.6 0.6 8.8 5.7 7.5 0.6 8.8 5.7 314 5 319 165 -6.6 0.1 -6.4 -6.8 01/26/2006 14:30:00 6.7 0.6 8 4.6 6.7 0.6 8 4.6 6.3 0.9 8 4.2 312 6 315 165 -6.7 0 -6.6 -6.8 01/26/2006 14:40:00 6.3 0.5 7.2 4.9 6.3 0.5 7.2 4.9 5.8 0.8 7.6 3.8 313 5 313 165 -6.9 0 -6.6 -7 01/26/2006 14:50:00 6.6 0.6 8 4.6 6.6 0.6 8 4.6 5.1 0.6 6.5 3.4 301 6 292 165 -6.9 0.1 -6.6 -7.2 01/26/2006 15:00:00 5.9 0.8 7.6 3.8 6 0.8 7.6 3.8 4.7 0.7 7.2 3 302 6 302 165 -7.1 0.2 -6.8 -7.4 01/26/2006 15:10:00 6.1 0.5 7.6 4.9 6.1 0.5 7.2 4.9 5.4 0.8 7.2 3.4 310 6 300 165 -7.3 0.1 -6.8 -7.4 01/26/2006 15:20:00 5.9 0.6 7.6 4.6 5.9 0.6 7.6 4.6 5.3 0.7 6.8 3.4 312 4 318 165 -7.1 0 -6.8 -7.2 01/26/2006 15:30:00 5.4 0.5 6.8 3.8 5.4 0.5 6.5 4.2 5.1 0.6 6.5 3.4 314 6 314 165 -7 0 -6.8 -7.2 01/26/2006 15:40:00 5.5 0.6 7.2 4.2 5.5 0.6 6.8 3.8 5.1 0.8 7.2 3 314 5 310 165 -7 0 -6.8 -7.2 01/26/2006 15:50:00 6.1 0.5 7.2 4.9 6 0.5 7.2 4.9 5.7 0.7 6.8 3.8 313 5 311 165 -7.1 0 -6.8 -7.2 01/26/2006 16:00:00 6 0.5 7.2 4.9 5.9 0.5 6.8 4.9 5.3 0.9 6.8 3 313 8 314 165 -7.4 0.1 -7.2 -7.6 01/26/2006 16:10:00 6.5 0.4 7.6 5.3 6.5 0.4 7.2 4.9 6.2 0.6 7.2 4.2 314 4 315 165 -7.6 0.2 -7.2 -8.1 01/26/2006 16:20:00 6.8 0.5 8 5.7 6.7 0.5 8.4 5.3 6.3 0.7 8 4.6 313 5 319 165 -8 0 -7.9 -8.1 01/26/2006 16:30:00 7.1 0.4 8 5.7 7 0.4 8 5.7 6.6 0.6 7.6 4.6 313 3 312 165 -8.1 0 -8.1 -8.3 01/26/2006 16:40:00 6.4 0.8 7.6 4.2 6.3 0.8 7.6 4.2 6.2 0.8 7.6 3.4 317 4 314 165 -8.1 0 -7.9 -8.3 01/26/2006 16:50:00 4.6 0.4 5.7 3.4 4.5 0.4 5.7 3.4 4.5 0.4 5.7 3.4 322 7 324 165 -7.9 0 -7.6 -8.1 01/26/2006 17:00:00 4.8 0.6 6.5 3.4 4.7 0.6 6.5 3.4 4.7 0.5 6.5 3.8 332 9 333 165 -8.2 0.2 -7.6 -8.5 01/26/2006 17:10:00 4 0.6 5.3 1.9 3.9 0.6 4.9 2.3 3.9 0.6 5.3 2.3 335 15 348 165 -8.5 0 -8.1 -8.7 01/26/2006 17:20:00 4.7 0.6 6.1 3 4.7 0.6 6.1 3.4 4.4 0.8 6.1 2.6 311 9 319 165 -8.5 0.1 -8.3 -8.9 01/26/2006 17:30:00 5.2 0.5 6.8 3.8 5.1 0.5 6.5 3.8 4.8 0.6 6.1 3 314 7 315 165 -9 0.1 -8.7 -9.1 01/26/2006 17:40:00 3.9 0.6 5.3 2.6 3.9 0.6 5.3 2.3 3.7 0.4 4.9 2.6 324 14 301 165 -9.1 0 -8.9 -9.3 01/26/2006 17:50:00 3.9 0.6 5.7 2.3 3.9 0.5 5.3 2.6 3.8 0.5 5.3 1.9 327 14 353 165 -8.9 0.1 -8.5 -9.1 01/26/2006 18:00:00 6.5 0.4 7.6 5.7 5.7 0.9 8 3.4 6.7 0.4 7.6 5.3 352 4 353 165 -9.1 0 -8.9 -9.3 01/26/2006 18:10:00 6.1 0.5 7.2 4.9 5.4 1 7.2 2.6 6.3 0.5 7.6 4.9 351 5 2 165 -8.8 0 -8.5 -9.1 01/26/2006 18:20:00 4.6 1 6.8 2.6 4.6 1 6.8 2.6 4.6 1 6.8 3 327 13 346 165 -8.9 0.2 -8.5 -9.3 01/26/2006 18:30:00 4.1 0.4 5.3 2.6 4.1 0.5 5.3 2.6 4.1 0.5 5.3 2.6 334 7 342 165 -9 0.1 -8.7 -9.1 01/26/2006 18:40:00 4.2 0.3 5.3 3.4 4.2 0.3 5.3 3.4 4.1 0.4 4.9 2.6 327 13 334 165 -9.1 0 -8.9 -9.1 01/26/2006 18:50:00 4.1 0.5 5.7 3.4 4.1 0.5 5.7 3 3.9 0.4 4.9 3 321 13 300 165 -9.1 0 -8.9 -9.1 01/26/2006 19:00:00 4.9 0.8 7.2 2.6 4.9 0.8 7.2 3 4.4 0.7 6.1 2.6 308 11 293 165 -9 0 -8.7 -9.1 01/26/2006 19:10:00 5.5 0.7 7.2 3.8 5.5 0.7 7.2 3.4 5 0.6 6.5 3 312 8 307 165 -9.1 0.1 -8.9 -9.3 01/26/2006 19:20:00 3.9 0.5 4.9 2.6 3.8 0.5 4.9 2.3 3.8 0.5 4.9 2.6 323 16 305 165 -8.9 0.2 -8.5 -9.3 01/26/2006 19:30:00 4.1 0.5 5.7 3 4 0.5 5.7 3 3.7 0.6 4.9 2.3 315 13 322 165 -8.8 0 -8.5 -9.1 01/26/2006 19:40:00 4.3 0.4 5.7 3 4.2 0.4 5.3 3.4 4.2 0.4 5.3 3 322 9 321 165 -8.9 0 -8.7 -9.1 01/26/2006 19:50:00 4.2 0.5 5.7 2.6 4.2 0.5 5.3 2.6 3.8 0.5 4.9 1.9 312 12 301 165 -8.9 0.1 -8.5 -9.1 01/26/2006 20:00:00 4 0.7 6.1 2.6 4 0.7 6.1 2.6 3.7 0.8 6.1 1.5 298 11 284 165 -8.8 0.1 -8.5 -8.9 01/26/2006 20:10:00 4.6 0.6 6.1 3 4.5 0.6 6.1 3 3.9 0.7 5.7 1.9 309 10 308 165 -8.8 0 -8.5 -8.9 01/26/2006 20:20:00 5.7 0.8 7.2 3.8 5.7 0.8 7.2 3.8 5 0.7 6.5 3 312 8 310 165 -9.1 0 -8.9 -9.1 01/26/2006 20:30:00 5.4 1 7.6 3.4 5.4 1 7.2 3 4.3 0.9 6.5 2.3 298 10 307 165 -8.9 0.1 -8.7 -9.1 01/26/2006 20:40:00 6.5 1.1 8.8 3.8 6.6 1.1 9.5 3.8 5.8 1.1 9.5 3.4 288 9 278 165 -8.8 0 -8.7 -8.9 01/26/2006 20:50:00 5.5 0.9 8 3.4 5.5 1 8 3.4 4.8 0.8 7.2 2.3 300 10 300 165 -8.9 0 -8.7 -9.1 01/26/2006 21:00:00 4 0.8 5.7 2.6 4 0.8 5.7 2.6 3.4 0.6 5.7 1.9 305 8 300 165 -8.9 0.1 -8.7 -9.1 01/26/2006 21:10:00 3.7 0.4 4.6 2.6 3.7 0.4 4.6 2.6 3.5 0.4 4.6 2.3 313 6 315 165 -9.2 0 -8.9 -9.3 01/26/2006 21:20:00 3.1 0.4 4.2 1.9 3.1 0.4 3.8 1.9 3.2 0.4 3.8 2.3 331 10 338 165 -9.3 0 -8.9 -9.5 01/26/2006 21:30:00 3.4 0.6 4.9 1.9 3.4 0.6 4.9 1.9 2.9 0.5 4.2 1.5 303 14 293 165 -9.2 0.1 -9.1 -9.7 01/26/2006 21:40:00 4.9 0.8 6.5 3 4.9 0.8 6.5 3 4.1 0.8 6.1 2.3 295 6 291 165 -9 0 -8.9 -9.1 01/26/2006 21:50:00 5 1 6.8 3 5 1 7.2 3.4 4 0.8 6.8 2.3 299 9 291 165 -9 0 -8.9 -9.1 01/26/2006 22:00:00 3.1 0.6 4.6 1.9 3.1 0.6 4.6 1.9 2.9 0.6 4.6 1.5 312 12 312 165 -9.2 0 -8.9 -9.3 01/26/2006 22:10:00 2.4 0.5 3.8 1.1 2.4 0.6 3.8 0.7 2.4 0.5 3.4 0.4 328 12 331 165 -8.8 0 -8.5 -8.9 01/26/2006 22:20:00 2.6 0.7 4.2 1.1 2.7 0.6 4.2 1.5 2.4 0.6 3.8 1.1 316 11 305 165 -8.5 0 -8.3 -8.7 01/26/2006 22:30:00 2.7 0.5 3.8 1.5 2.6 0.6 3.8 0.7 2.7 0.4 3.8 1.9 327 13 313 165 -8.3 0 -8.1 -8.5 01/26/2006 22:40:00 2 0.4 3 1.1 1.5 0.4 2.3 0.4 2.2 0.3 3 1.1 3 7 354 165 -8.7 0.2 -8.3 -8.9 01/26/2006 22:50:00 1.1 0.3 1.9 0.4 1 0.4 1.9 0.4 1.2 0.3 1.9 0.7 14 11 18 165 -8.7 0.1 -8.5 -8.9 01/26/2006 23:00:00 2.1 1 4.6 0.7 2.2 1 4.6 0.7 2.1 1 4.2 0.4 303 18 295 165 -8.6 0 -8.5 -8.7 01/26/2006 23:10:00 4.8 0.3 5.3 4.2 4.8 0.3 5.3 4.2 3.9 0.5 5.3 2.6 295 3 298 165 -8.9 0 -8.5 -8.9 01/26/2006 23:20:00 4.7 0.5 6.1 3.4 4.7 0.5 6.5 3.4 4 0.5 5.3 2.6 292 4 296 165 -8.9 0 -8.7 -9.1 01/26/2006 23:30:00 4.3 0.7 6.1 2.6 4.3 0.7 6.5 3 3.6 0.6 5.3 1.9 307 8 297 165 -9 0 -8.7 -9.1 01/26/2006 23:40:00 5 0.8 6.5 3.4 4.9 0.8 6.5 3 4.2 0.6 5.7 2.6 308 8 301 165 -9.1 0.1 -8.9 -9.3 01/26/2006 23:50:00 6.1 0.6 7.6 4.2 6.1 0.6 7.6 4.2 4.7 0.6 6.5 3 301 5 302 165 -8.9 0 -8.9 -9.1 01/27/2006 00:00:00 7 0.5 8.4 5.3 7 0.5 8.4 5.3 5.2 0.7 8 3.4 298 4 293 165 -9.1 0 -8.9 -9.1 01/27/2006 00:10:00 6 0.7 7.6 4.6 6 0.6 7.2 4.2 4.3 0.6 5.7 2.6 301 4 298 165 -9.2 0 -8.9 -9.3 01/27/2006 00:20:00 6.1 0.5 7.2 4.6 6 0.5 7.2 4.6 4.4 0.7 6.8 2.6 302 5 298 165 -9.3 0 -9.1 -9.3 01/27/2006 00:30:00 5.4 0.8 7.2 4.2 5.3 0.8 7.2 3.8 4.5 0.5 6.1 3 309 10 303 165 -9.2 0.1 -8.9 -9.5 01/27/2006 00:40:00 4.2 0.4 5.7 3 4.2 0.4 5.7 3 4.1 0.4 5.3 3 321 7 310 165 -9.3 0 -9.1 -9.3 01/27/2006 00:50:00 4.3 0.4 5.3 3 4.2 0.4 5.7 3 4 0.5 4.9 2.3 313 10 292 165 -9.3 0 -9.1 -9.7 01/27/2006 01:00:00 4.6 0.6 6.1 3 4.5 0.6 6.1 3 4.5 0.7 6.5 2.6 326 15 341 165 -9.6 0 -9.3 -9.7 01/27/2006 01:10:00 5.8 0.8 8 3.8 5.9 0.9 8.4 3.8 5.7 0.7 7.2 3.8 339 8 347 165 -9.7 0 -9.5 -10.2 01/27/2006 01:20:00 5.3 0.8 7.2 3.8 5.3 0.8 7.2 3.8 5.4 0.8 7.2 3.8 336 9 352 165 -9.6 0.1 -9.3 -10.2 01/27/2006 01:30:00 5.3 0.7 6.8 3.8 4.7 0.9 7.2 2.6 5.4 0.6 6.8 4.2 349 6 355 165 -9.9 0 -9.7 -10.2 01/27/2006 01:40:00 4.9 0.8 6.8 2.6 4.5 0.9 6.8 2.3 4.9 0.6 6.5 3.4 346 9 334 165 -10.1 0 -10 -10.2 01/27/2006 01:50:00 4.4 0.7 6.1 2.3 4 0.7 5.7 1.9 4.1 0.7 5.7 1.9 332 21 6 165 -10 0.1 -9.7 -10.2 01/27/2006 02:00:00 6.8 1.2 9.5 3 6.8 1.2 9.5 3 5.5 0.8 8 3 307 7 301 165 -9.9 0 -9.7 -10 01/27/2006 02:10:00 6.2 1 8.4 4.6 6.1 0.9 8 4.2 5.7 0.8 7.6 3.4 314 10 312 165 -9.9 0 -9.7 -10.2 01/27/2006 02:20:00 5.3 0.8 7.2 3 5.2 0.7 7.2 3.4 4.8 0.6 6.5 3.4 316 15 304 165 -10 0 -9.7 -10.2 01/27/2006 02:30:00 5.2 0.5 6.5 3.4 5.2 0.5 6.5 3.4 4.5 0.6 6.1 2.6 312 14 303 165 -10.2 0.1 -10 -10.6 01/27/2006 02:40:00 4.6 0.8 6.8 2.6 4.3 0.8 6.8 2.3 4.6 0.8 7.2 2.6 335 17 326 165 -10.1 0.2 -9.7 -10.6 01/27/2006 02:50:00 4.3 0.5 6.1 3 4.3 0.5 6.1 3 4.3 0.5 5.7 3 335 11 333 165 -10.1 0 -9.7 -10.2 01/27/2006 03:00:00 4.4 0.5 6.1 3 3.9 0.8 6.1 1.9 4.4 0.5 5.7 3 346 12 332 165 -10.5 0.1 -10.2 -10.8 01/27/2006 03:10:00 4.4 0.5 6.1 2.6 3.8 0.8 6.1 1.9 4.4 0.6 5.7 3 342 23 317 165 -10.5 0 -10.2 -10.8 01/27/2006 03:20:00 5.6 1.5 8.4 2.6 5.5 1.5 8.4 1.5 5.3 1.3 8 3 320 14 315 165 -10.4 0 -10.2 -10.6 01/27/2006 03:30:00 6.7 0.7 8 4.9 6.7 0.7 8 4.9 5.3 0.7 7.2 3.4 307 6 305 165 -10.5 0 -10.4 -10.6 01/27/2006 03:40:00 6.3 0.8 8.4 4.6 6.2 0.8 8.4 4.6 6.1 0.8 8 4.2 322 9 315 165 -10.4 0 -10.2 -10.6 01/27/2006 03:50:00 7.5 0.6 9.1 6.1 7.4 0.6 9.1 5.7 7.3 0.7 9.1 5.7 322 8 322 165 -10.8 0.1 -10.6 -11 01/27/2006 04:00:00 7.1 0.9 9.5 5.3 7 0.9 9.5 5.3 6.9 0.7 9.5 5.3 320 7 304 165 -10.9 0 -10.8 -11 01/27/2006 04:10:00 6.7 0.8 9.1 4.6 5.6 1 8 3 6.7 1 9.1 3.8 349 12 355 165 -11.1 0.1 -10.8 -11.4 01/27/2006 04:20:00 5.8 0.7 7.6 4.2 5.3 0.8 7.2 3 6.1 0.8 8 4.2 341 12 354 165 -11.2 0 -11 -11.4 01/27/2006 04:30:00 5.7 0.5 6.8 4.6 5.7 0.4 6.8 4.6 5.6 0.5 7.6 4.2 327 10 314 165 -11.2 0 -11 -11.4 01/27/2006 04:40:00 6 0.8 8.8 4.2 6 0.8 9.1 4.2 5.7 1 7.6 3.4 319 13 298 165 -11.1 0.1 -10.8 -11.4 01/27/2006 04:50:00 8.5 1.4 11.8 5.3 8.4 1.4 11.8 5.7 7.3 1 9.9 4.6 310 8 304 165 -11 0 -11 -11.2 01/27/2006 05:00:00 10.5 0.8 12.6 8.4 10.5 0.8 12.6 8.8 7.8 1.1 11.1 5.3 301 6 302 165 -11.1 0 -11 -11.2 01/27/2006 05:10:00 9.3 1 12.2 6.8 9.3 1 12.2 7.2 7.2 1.1 10.3 4.9 300 7 297 165 -11.2 0 -11 -11.4 01/27/2006 05:20:00 9.8 1.3 12.6 6.5 9.8 1.3 12.2 6.5 7.6 1.2 11.1 4.9 298 7 300 165 -11.3 0.1 -11 -11.4 01/27/2006 05:30:00 9.3 1.5 12.2 4.9 9.3 1.5 11.8 4.9 7.1 1 10.7 4.2 300 7 284 165 -11.2 0 -11 -11.4 01/27/2006 05:40:00 10.2 1.3 12.6 6.1 10.1 1.3 13 6.1 8.1 1.2 11.5 4.9 306 6 305 165 -11.1 0 -11 -11.2 01/27/2006 05:50:00 9.8 1 12.2 7.2 9.7 1 12.2 7.2 8.3 1.2 11.1 5.3 310 5 307 165 -11.2 0 -11 -11.4 01/27/2006 06:00:00 10.8 0.7 13 9.1 10.8 0.7 13 9.1 7.9 1 11.1 6.1 304 4 298 165 -11.2 0 -11 -11.4 01/27/2006 06:10:00 9.9 0.7 11.8 7.6 9.8 0.7 11.5 7.6 8.2 1 10.7 5.7 308 5 307 165 -11.6 0.2 -11.2 -11.8 01/27/2006 06:20:00 11.5 1.2 14.1 8.4 11.4 1.2 14.1 8.4 8.9 1.3 14.1 6.1 304 6 295 165 -11.9 0 -11.8 -12 01/27/2006 06:30:00 14.6 1.3 17.2 11.1 14.5 1.4 17.6 10.3 10.6 1.4 15.3 7.2 297 5 295 165 -11.9 0 -11.8 -12 01/27/2006 06:40:00 15 1.1 17.9 12.6 15 1.1 17.9 12.2 11 1.3 16.4 8.4 298 5 298 165 -11.9 0 -11.8 -12.2 01/27/2006 06:50:00 14.6 1.5 18.3 10.7 14.5 1.5 17.9 10.3 10.4 1.3 14.5 7.2 299 5 304 165 -12 0 -11.8 -12.2 01/27/2006 07:00:00 13 1.5 16.4 9.1 12.9 1.5 16.1 9.1 10.3 1.2 13.3 7.2 303 7 304 165 -12.1 0 -12 -12.2 01/27/2006 07:10:00 14.7 1.7 17.9 9.1 14.6 1.7 17.9 9.1 12.5 1.7 17.2 8 307 5 302 165 -12.3 0 -12.2 -12.4 01/27/2006 07:20:00 16.7 2 20.6 10.7 16.7 2 20.2 11.5 13.8 2.2 19.1 8.8 304 5 306 165 -12.4 0 -12.2 -12.6 01/27/2006 07:30:00 18.3 1.1 21.4 14.5 18.2 1.1 21.4 14.9 16.9 1.5 21.4 11.5 309 4 302 165 -12.4 0 -12.4 -12.6 01/27/2006 07:40:00 17.5 1.6 21.8 13.3 17.4 1.6 21.8 13 16.3 1.7 20.6 11.1 309 5 302 165 -12.6 0 -12.4 -12.6 01/27/2006 07:50:00 17.6 1.7 21.8 13.3 17.6 1.7 21.8 13.3 15.3 2.1 21 10.7 305 6 304 165 -12.8 0 -12.6 -13 01/27/2006 08:00:00 16.8 1.3 20.2 13.3 16.8 1.3 19.9 13.3 14.8 1.9 19.5 9.9 307 6 295 165 -13 0 -12.6 -13.2 01/27/2006 08:10:00 17.5 1.1 20.2 14.5 17.5 1.2 20.2 14.9 16.9 1.4 20.6 12.6 311 4 309 165 -13.2 0 -13.2 -13.4 01/27/2006 08:20:00 16.1 1.5 19.1 12.6 16.1 1.5 19.5 12.6 16 1.4 19.5 12.6 314 5 313 165 -13.3 0 -13.2 -13.4 01/27/2006 08:30:00 14.7 1 16.8 11.8 14.7 1 16.8 11.8 14.4 1 16.4 10.7 313 4 314 165 -13.3 0 -13.2 -13.6 01/27/2006 08:40:00 12.6 1.3 15.6 9.9 12.6 1.3 15.6 9.5 12.4 1.2 16.1 9.5 315 6 315 165 -13.3 0 -13.2 -13.6 01/27/2006 08:50:00 10.2 1.5 12.6 5.7 10.1 1.5 12.6 5.7 9.7 1.5 13 5.7 315 12 318 165 -13.4 0.1 -13.2 -13.6 01/27/2006 09:00:00 8.8 0.9 11.5 6.5 7.2 1.6 11.1 3.8 8.7 0.9 11.5 6.5 358 9 13 165 -13.7 0 -13.6 -14 01/27/2006 09:10:00 9 1 11.1 6.5 7.7 1.5 10.7 3.8 8.7 1 10.7 5.7 13 8 10 165 -14.1 0.1 -13.8 -14.4 01/27/2006 09:20:00 8 1.3 11.8 4.2 6.7 1.6 11.1 3 7.6 1.3 11.5 3.4 10 10 13 165 -14.4 0 -14.2 -14.6 01/27/2006 09:30:00 7.6 1.3 11.1 3 5.9 1.2 8.8 2.6 7.3 1.7 11.8 1.9 359 14 353 165 -14.6 0 -14.4 -14.6 01/27/2006 09:40:00 9 1.7 12.2 4.9 8.9 1.7 12.2 4.9 8.5 1.7 11.5 4.6 317 8 305 165 -14.6 0 -14.6 -14.6 01/27/2006 09:50:00 7.8 1.2 11.1 4.9 7.7 1.2 11.1 4.9 7.3 1.2 10.7 4.2 317 11 308 165 -14.7 0 -14.6 -14.8 01/27/2006 10:00:00 8.5 1.2 11.5 5.3 8.3 1.2 11.1 4.9 7.8 1.1 10.7 4.9 315 11 302 165 -14.9 0 -14.6 -15 01/27/2006 10:10:00 7.7 2.1 14.1 4.6 7.7 2.2 13.7 4.6 7.2 2.4 13.7 3.4 323 16 305 165 -15.1 0.1 -15 -15.2 01/27/2006 10:20:00 10.6 1.3 14.5 7.2 10.5 1.4 14.1 6.5 10 1.3 13.7 6.8 323 14 304 165 -15.2 0 -15.2 -15.3 01/27/2006 10:30:00 10.1 1.5 14.5 6.5 10 1.5 14.9 6.8 9.5 1.8 16.8 5.7 321 12 330 165 -15.3 0 -15.2 -15.3 01/27/2006 10:40:00 10 2.5 16.1 5.3 10 2.4 15.6 5.3 9.4 2.6 15.3 4.2 317 9 313 165 -15.2 0 -15.2 -15.3 01/27/2006 10:50:00 10.5 2.3 17.2 6.5 10.4 2.3 17.2 6.5 9.9 2.1 14.9 5.7 323 12 304 165 -15.2 0 -15 -15.3 01/27/2006 11:00:00 8.6 1.7 13 4.9 8.5 1.7 12.6 4.9 8.2 1.7 12.6 4.6 328 10 319 165 -15 0 -15 -15.2 01/27/2006 11:10:00 10.8 1.6 14.5 6.8 10.8 1.5 14.1 6.8 9.8 1.8 14.1 5.7 313 9 317 165 -15 0 -15 -15.2 01/27/2006 11:20:00 12.5 1.6 17.2 8.8 12.4 1.6 17.2 8.8 11.9 1.9 16.8 5.7 314 7 308 165 -15.1 0.1 -14.8 -15.3 01/27/2006 11:30:00 11.3 1.3 14.9 7.2 11.2 1.2 14.9 7.2 10.7 1.3 14.5 6.5 316 8 305 165 -15.2 0 -15 -15.3 01/27/2006 11:40:00 10.2 1.3 13 7.6 10.1 1.3 13.3 6.8 9.9 1.3 13.3 6.5 322 9 325 165 -15.2 0 -15 -15.2 01/27/2006 11:50:00 9.5 0.9 11.5 6.8 9.3 0.9 11.5 6.8 8.5 1 11.1 5.3 308 9 309 165 -15.2 0 -15 -15.3 01/27/2006 12:00:00 8.9 0.9 11.1 6.5 8.8 0.9 11.1 6.5 8.5 0.9 10.7 5.3 316 7 326 165 -15.1 0 -15 -15.2 01/27/2006 12:10:00 12 2.2 17.9 6.8 11.8 2.3 17.6 6.8 11.4 2.5 17.9 6.8 317 8 313 165 -15.1 0.1 -15 -15.2 01/27/2006 12:20:00 11.9 1.3 15.6 8.4 11.8 1.3 15.6 8 11.4 1.3 14.9 7.2 316 9 305 165 -15.3 0 -15 -15.5 01/27/2006 12:30:00 9.3 1.6 13 5.7 9.2 1.6 13 5.7 8.9 1.6 12.2 5.3 322 12 339 165 -15.6 0 -15.5 -15.7 01/27/2006 12:40:00 9.6 1.7 13.7 5.3 9.5 1.6 13.3 5.3 8.9 1.5 12.6 4.9 314 10 302 165 -15.6 0 -15.5 -15.7 01/27/2006 12:50:00 9.9 1.5 12.6 5.3 9.8 1.5 12.6 4.9 8.9 1.5 13 4.9 309 8 289 165 -15.5 0 -15.3 -15.7 01/27/2006 13:00:00 11.1 1.7 15.3 7.2 11.1 1.7 14.9 7.6 9.7 2.1 15.6 5.7 297 9 287 165 -15.6 0 -15.5 -15.7 01/27/2006 13:10:00 15 2.2 20.2 9.1 14.9 2.3 19.9 9.1 12.6 2.3 19.1 7.2 296 6 289 165 -15.8 0 -15.5 -15.9 01/27/2006 13:20:00 15.2 1.8 20.2 9.9 15.1 1.9 20.2 9.5 12.6 1.7 18.3 8.4 300 7 304 165 -15.9 0 -15.7 -16.1 01/27/2006 13:30:00 15.6 2.4 21.4 10.3 15.5 2.5 21.4 9.9 13 2.3 19.9 8.4 297 7 291 165 -16.1 0 -15.9 -16.3 01/27/2006 13:40:00 15.6 1.7 19.5 11.1 15.5 1.8 19.5 10.3 12.9 1.8 18.3 8.4 296 8 300 165 -16 0 -15.9 -16.3 01/27/2006 13:50:00 15 1.8 19.9 10.3 14.9 1.8 19.9 10.3 12.6 2.1 18.3 7.2 299 7 295 165 -16 0 -15.9 -16.1 01/27/2006 14:00:00 14.6 2 20.6 9.5 14.5 2 20.6 9.5 12.6 2.1 20.2 8 302 6 304 165 -16.1 0 -15.9 -16.3 01/27/2006 14:10:00 14.6 1.5 17.6 11.1 14.6 1.5 17.9 11.1 12.5 1.7 16.4 8.8 302 7 305 165 -16.1 0 -15.9 -16.3 01/27/2006 14:20:00 13 1.2 16.1 9.1 12.9 1.2 15.6 9.1 11.3 1.2 14.5 8 303 7 291 165 -16 0 -15.9 -16.1 01/27/2006 14:30:00 16 1.8 20.6 11.8 15.9 1.8 20.6 11.5 13.8 2 19.1 9.5 303 6 302 165 -16 0 -15.9 -16.1 01/27/2006 14:40:00 14.8 1.7 18.7 9.1 14.7 1.7 18.7 8.8 13.9 2.1 17.9 6.5 309 6 305 165 -16 0 -15.9 -15.9 01/27/2006 14:50:00 14.2 1.5 17.6 9.5 14.1 1.6 17.6 8.4 13.5 1.7 17.2 8 315 9 313 165 -16 0 -15.7 -16.1 01/27/2006 15:00:00 16.3 1.4 19.5 11.8 16.3 1.5 19.5 12.2 15.3 1.5 19.1 10.7 309 5 312 165 -16.2 0 -15.9 -16.3 01/27/2006 15:10:00 15.7 1.2 18.7 11.5 15.6 1.2 18.7 11.5 15.2 1.3 19.1 11.5 314 6 318 165 -16.2 0 -15.9 -16.3 01/27/2006 15:20:00 14.1 1.1 16.8 11.1 14 1.1 16.8 10.7 14.1 1.2 17.2 11.1 321 6 328 165 -16.2 0 -15.9 -16.3 01/27/2006 15:30:00 14.7 1.5 17.2 11.1 14.6 1.5 17.6 10.7 14.3 1.5 17.2 11.1 313 6 317 165 -16 0 -15.7 -16.3 01/27/2006 15:40:00 13.8 1.4 17.6 10.7 13.7 1.4 17.2 10.3 12.8 1.7 17.6 9.1 309 7 308 165 -15.8 0 -15.5 -15.9 01/27/2006 15:50:00 13.4 1.5 18.3 10.3 13.3 1.5 18.3 9.9 11.9 1.7 18.3 7.6 306 8 313 165 -15.7 0 -15.5 -15.7 01/27/2006 16:00:00 17.1 1.7 21 13 17.1 1.7 21 12.6 16.7 1.9 22.6 11.8 314 6 322 165 -15.6 0.1 -15.3 -15.9 01/27/2006 16:10:00 18.3 1.7 22.1 13.3 18.2 1.7 21.8 13.3 18.4 1.8 22.6 13.3 319 5 319 165 -15.9 0 -15.7 -15.9 01/27/2006 16:20:00 17.2 1.5 20.2 12.6 17.2 1.5 20.2 13.3 17.1 1.6 20.6 12.2 318 7 310 165 -16.2 0.1 -15.9 -16.3 01/27/2006 16:30:00 14.7 1.6 19.1 10.7 14.7 1.6 19.1 11.1 14.5 1.7 19.9 10.3 316 8 332 165 -16.1 0 -15.9 -16.3 01/27/2006 16:40:00 14.8 1.6 18.3 10.3 14.7 1.6 18.3 10.3 13.5 2 17.9 7.6 309 7 305 165 -15.8 0.1 -15.5 -15.9 01/27/2006 16:50:00 13.1 1.5 17.2 9.1 13 1.5 17.2 9.1 11.6 1.7 16.1 8 307 9 323 165 -15.7 0 -15.5 -15.7 01/27/2006 17:00:00 14.2 1.7 17.6 8.8 14.1 1.7 17.6 9.1 12.1 1.8 17.2 7.2 300 8 309 165 -15.7 0 -15.5 -15.7 01/27/2006 17:10:00 15.4 1.7 20.6 9.9 15.4 1.7 20.2 9.9 13.2 1.9 19.5 8.4 302 8 304 165 -15.7 0 -15.5 -15.7 01/27/2006 17:20:00 16.3 2.1 21.4 11.1 16.2 2.1 21 11.1 14.9 2.6 20.6 7.6 307 8 312 165 -15.6 0 -15.5 -15.7 01/27/2006 17:30:00 18.9 2.2 23.7 13.7 18.9 2.2 24 13.3 18.2 2.1 22.9 13 310 7 305 165 -15.5 0 -15.3 -15.7 01/27/2006 17:40:00 15.9 1.5 21.4 12.2 15.9 1.5 21.4 12.2 15.4 1.7 21.8 9.9 313 7 307 165 -15.5 0.1 -15.3 -15.7 01/27/2006 17:50:00 17.1 1.7 22.6 12.6 17 1.7 22.6 12.6 16.9 1.7 21.8 11.5 316 6 304 165 -15.7 0 -15.5 -15.7 01/27/2006 18:00:00 20.6 1.7 26 16.4 20.6 1.7 25.6 16.1 20.2 1.8 26 16.1 315 6 316 165 -15.7 0 -15.5 -15.9 01/27/2006 18:10:00 21 1.7 24.8 16.4 21 1.7 24.8 16.1 20.6 1.9 25.2 16.1 318 6 314 165 -15.9 0 -15.7 -15.9 01/27/2006 18:20:00 21.3 1.8 25.6 15.6 21.2 1.8 26 15.6 21.1 2 26.3 16.4 319 6 313 165 -16.1 0 -15.9 -16.3 01/27/2006 18:30:00 20.6 2.5 25.2 13.3 20.5 2.5 25.2 12.6 20.3 2.6 25.2 11.8 320 7 295 165 -16.2 0 -15.9 -16.3 01/27/2006 18:40:00 19.8 1.7 24 14.1 19.7 1.7 23.7 14.1 19.7 1.7 23.7 14.9 322 8 330 165 -16 0 -15.9 -16.1 01/27/2006 18:50:00 18.9 2.1 27.5 14.1 18.9 2.1 26.8 13.3 18.7 2.2 26 13.7 321 6 318 165 -15.9 0 -15.7 -15.9 01/27/2006 19:00:00 19 2.3 23.7 12.2 19 2.3 23.3 11.8 18.7 2.6 23.7 11.5 322 8 312 165 -15.8 0 -15.7 -16.1 01/27/2006 19:10:00 18.7 2.5 25.2 10.3 18.6 2.6 25.6 9.1 18.2 2.8 25.2 8.4 323 9 302 165 -15.7 0 -15.5 -15.9 01/27/2006 19:20:00 18.3 2 22.1 13 18.3 2 22.1 13 17.7 2.2 22.1 12.2 317 9 316 165 -15.7 0 -15.5 -15.7 01/27/2006 19:30:00 18.8 1.9 23.7 13.7 18.7 2 23.3 13 18.3 2.3 23.3 12.6 316 6 321 165 -15.6 0 -15.5 -15.7 01/27/2006 19:40:00 18.9 2.4 24 13 18.8 2.4 24 12.6 18.3 2.5 23.7 11.5 315 7 307 165 -15.7 0 -15.5 -15.7 01/27/2006 19:50:00 18.5 2.4 25.6 12.2 18.4 2.4 25.6 11.8 17.9 2.6 26.8 11.8 316 7 319 165 -15.6 0 -15.5 -15.7 01/27/2006 20:00:00 20.8 1.9 24.8 15.6 20.7 2 24 15.6 20.2 2.1 24.8 13 315 6 310 165 -15.6 0 -15.5 -15.7 01/27/2006 20:10:00 22.9 1.9 27.9 17.9 22.9 1.9 27.9 17.9 22.4 2.2 26.8 16.4 313 6 307 165 -15.6 0 -15.5 -15.7 01/27/2006 20:20:00 18.6 2.2 22.9 13 18.6 2.2 23.3 13.3 18.1 2 23.3 12.6 313 7 309 165 -15.6 0 -15.5 -15.7 01/27/2006 20:30:00 18.8 2.2 25.2 12.2 18.8 2.2 25.2 11.8 18.5 2.3 24.8 12.6 317 7 313 165 -15.5 0 -15.3 -15.7 01/27/2006 20:40:00 19.6 2.6 25.2 14.5 19.6 2.6 25.6 14.5 19.1 2.7 25.6 13.3 314 6 314 165 -15.4 0 -15.3 -15.5 01/27/2006 20:50:00 19.8 1.9 27.1 15.3 19.8 1.9 27.1 16.1 19.4 2 24.8 14.9 317 7 316 165 -15.6 0 -15.3 -15.7 01/27/2006 21:00:00 20.5 2.4 26.3 13 20.5 2.4 26.8 12.6 20.1 2.7 27.1 13.3 319 9 318 165 -15.8 0 -15.5 -15.9 01/27/2006 21:10:00 19 2.6 24.8 10.3 18.9 2.6 24.4 11.5 18.1 2.8 24.4 8.4 322 9 307 165 -16.1 0.1 -15.9 -16.3 01/27/2006 21:20:00 20.4 2.4 26 13.3 20.3 2.4 26 12.6 20.3 2.6 26.8 12.2 322 8 323 165 -16.3 0 -15.9 -16.3 01/27/2006 21:30:00 21.8 1.8 26.3 16.8 21.7 1.8 26.8 16.4 21.3 2.2 26.3 16.1 323 7 313 165 -16.3 0 -16.1 -16.5 01/27/2006 21:40:00 22.6 2.4 28.7 14.9 22.6 2.4 28.3 14.5 22.2 2.5 27.5 15.6 319 8 324 165 -16.1 0 -15.9 -16.3 01/27/2006 21:50:00 22.6 2 27.9 17.2 22.6 2 28.3 17.2 22.2 2.3 29.1 16.1 313 6 319 165 -16 0 -15.9 -16.3 01/27/2006 22:00:00 22 1.9 26.8 16.8 22 1.9 27.1 16.8 21.2 2.2 26.8 14.9 311 6 310 165 -15.8 0.1 -15.7 -15.9 01/27/2006 22:10:00 23.6 2 28.7 17.9 23.6 2 29.1 18.3 22.9 2.2 29.1 16.8 311 5 305 165 -16 0.1 -15.7 -16.3 01/27/2006 22:20:00 24.6 1.9 29.4 17.6 24.6 2 29.4 17.6 24 2.1 29.1 17.6 311 6 316 165 -16.3 0 -15.9 -16.3 01/27/2006 22:30:00 25.4 1.9 29.4 19.1 25.5 1.9 29.4 19.1 25.2 2 29.1 19.1 312 5 315 165 -16.3 0 -16.1 -16.3 01/27/2006 22:40:00 23.7 2 27.9 17.6 23.7 2 27.9 17.6 23 2.2 29.4 16.8 313 6 308 165 -16.1 0.1 -15.9 -16.3 01/27/2006 22:50:00 23.3 2.2 28.7 16.8 23.2 2.2 28.7 16.4 22.3 2.7 29.1 15.6 309 6 313 165 -15.8 0 -15.5 -15.9 01/27/2006 23:00:00 21.9 2.2 27.1 13.7 21.8 2.2 27.1 14.1 20.8 2.8 27.5 10.7 310 6 301 165 -15.6 0 -15.3 -15.7 01/27/2006 23:10:00 19.9 2.6 25.6 13.7 19.9 2.5 25.2 13.7 18.4 2.7 24.4 9.9 311 9 296 165 -15.2 0 -15 -15.5 01/27/2006 23:20:00 19.5 2 24 13.7 19.4 2 24 13.7 18.1 2.4 24.4 11.1 311 8 307 165 -15 0 -14.8 -15.2 01/27/2006 23:30:00 18.2 2.4 24 11.5 18.1 2.4 24 11.5 17.8 2.7 24.4 10.3 317 8 320 165 -14.9 0 -14.8 -15 01/27/2006 23:40:00 17.5 2.6 23.3 9.9 17.4 2.6 23.3 9.9 17 2.5 22.9 8.4 322 11 312 165 -15.1 0.1 -14.8 -15.3 01/27/2006 23:50:00 22 2.2 27.1 16.4 21.9 2.3 26.8 15.6 21.1 2.5 27.1 15.3 315 6 317 165 -15.2 0 -15 -15.3 01/28/2006 00:00:00 20.3 2.2 27.1 14.1 20.3 2.2 27.1 14.5 19.9 2.3 26.8 14.5 316 7 321 165 -15.1 0 -15 -15.2 01/28/2006 00:10:00 22.3 2 27.5 15.6 22.3 2.1 27.1 14.9 21.7 2.2 27.9 16.4 312 5 304 165 -14.9 0 -14.8 -15.2 01/28/2006 00:20:00 21.2 1.9 26.8 16.1 21.2 1.9 26.8 16.1 19.9 2.2 25.6 13.3 311 7 310 165 -14.9 0 -14.8 -15 01/28/2006 00:30:00 23.1 1.8 27.1 17.9 23.1 1.8 27.1 17.6 22.7 1.9 27.1 16.8 314 6 311 165 -15.3 0.1 -15 -15.5 01/28/2006 00:40:00 22.3 2.4 27.9 15.3 22.2 2.4 28.3 15.6 21.9 2.5 27.9 15.3 318 7 314 165 -15.6 0.1 -15.5 -15.9 01/28/2006 00:50:00 23.9 2.1 28.3 18.3 23.8 2.1 27.5 18.3 23.4 2.4 27.9 15.6 314 6 324 165 -16 0 -15.7 -16.1 01/28/2006 01:00:00 24.1 1.9 27.9 18.7 24.1 1.9 28.3 19.1 23.6 2 28.3 19.1 312 6 307 165 -16.2 0.1 -15.9 -16.3 01/28/2006 01:10:00 23.6 2 28.3 19.5 23.6 2 28.3 19.1 23.3 2.1 28.3 16.4 316 8 305 165 -16.3 0 -16.1 -16.5 01/28/2006 01:20:00 24.1 1.9 29.1 19.1 24 2 29.1 18.7 23.4 2.2 28.3 17.2 314 7 309 165 -16.2 0 -15.9 -16.3 01/28/2006 01:30:00 23.4 2.2 29.1 17.9 23.4 2.2 28.7 17.6 22.7 2 27.9 16.4 314 7 307 165 -16.1 0 -15.9 -16.3 01/28/2006 01:40:00 24 1.9 28.7 19.1 24 1.9 29.1 19.1 23.1 2.2 28.7 16.4 312 7 311 165 -15.8 0.1 -15.5 -15.9 01/28/2006 01:50:00 25.3 2.3 31.3 18.7 25.2 2.4 30.9 18.7 24.8 2.6 31.3 17.2 313 6 309 165 -15.8 0 -15.5 -15.9 01/28/2006 02:00:00 25.5 2.2 30.2 19.9 25.5 2.2 30.6 19.9 24.9 2.4 30.6 19.5 313 6 315 165 -15.8 0 -15.5 -15.9 01/28/2006 02:10:00 27.8 1.8 31.8 23.7 27.8 1.8 32.1 23.7 27 2.1 31.3 21.4 311 5 310 165 -15.8 0 -15.5 -15.9 01/28/2006 02:20:00 28.6 2.2 33.2 23.3 28.6 2.3 33.6 22.9 27.8 2.4 33.2 21 309 5 306 165 -15.7 0 -15.5 -15.9 01/28/2006 02:30:00 27.7 2.2 32.9 22.1 27.8 2.3 33.2 22.1 27.2 2.3 31.8 20.6 311 5 310 165 -15.7 0 -15.5 -15.7 01/28/2006 02:40:00 26.1 2.4 31.8 20.2 26.1 2.5 31.3 20.6 25.7 2.7 32.4 19.5 313 6 308 165 -15.7 0 -15.5 -15.7 01/28/2006 02:50:00 26.8 2.2 32.1 21.8 26.9 2.2 32.4 21.4 26.4 2.3 31.8 21 313 6 310 165 -15.6 0 -15.5 -15.7 01/28/2006 03:00:00 28.9 1.8 32.4 22.1 28.9 1.9 32.9 22.9 28.3 2.1 32.9 22.1 311 5 303 165 -15.4 0 -15.2 -15.5 01/28/2006 03:10:00 28.5 1.7 32.1 21.8 28.5 1.8 32.4 22.1 28.1 2 33.2 22.1 311 4 310 165 -15.2 0 -15 -15.3 01/28/2006 03:20:00 27.2 1.7 32.9 22.1 27.3 1.9 33.2 21.8 26.9 1.9 32.9 21.8 311 5 311 165 -14.9 0 -14.6 -15 01/28/2006 03:30:00 27.4 1.4 30.6 22.9 27.5 1.5 30.6 22.9 27.6 1.5 30.9 20.2 313 4 310 165 -14.7 0 -14.6 -15 01/28/2006 03:40:00 24.9 1.9 30.6 17.9 24.9 1.9 30.2 17.6 24.8 2.1 30.6 18.3 315 6 307 165 -14.8 0 -14.6 -15 01/28/2006 03:50:00 24.9 1.8 28.7 19.1 24.8 1.8 28.7 19.1 24.6 2 29.1 18.7 314 5 310 165 -14.5 0.1 -14.2 -14.8 01/28/2006 04:00:00 24.6 2 29.1 19.1 24.5 2 29.1 18.7 24.4 2.3 29.1 18.7 315 6 310 165 -14.1 0.1 -13.8 -14.4 01/28/2006 04:10:00 23.2 2.3 29.4 17.2 23.2 2.3 29.1 17.6 22.1 2.8 29.8 15.3 312 6 315 165 -13.8 0 -13.6 -14 01/28/2006 04:20:00 23.7 2.5 30.2 17.6 23.6 2.5 30.2 17.6 22.7 2.6 30.9 16.4 310 7 309 165 -13.6 0 -13.6 -13.8 01/28/2006 04:30:00 27.2 2.3 32.4 20.2 27.2 2.4 32.4 20.6 26.2 2.5 31.8 17.9 308 5 304 165 -13.5 0 -13.4 -13.6 01/28/2006 04:40:00 23.5 2.2 29.1 17.9 23.4 2.2 29.1 18.3 21.8 2.3 27.5 16.1 307 7 307 165 -13.6 0 -13.4 -13.8 01/28/2006 04:50:00 24.6 2.7 32.4 19.5 24.6 2.8 32.4 19.1 23.2 3.5 33.2 16.1 308 7 316 165 -13.7 0 -13.6 -13.8 01/28/2006 05:00:00 27.3 1.8 34 21.4 27.3 1.9 33.6 20.2 25.5 2.5 33.6 17.6 305 6 304 165 -13.7 0 -13.6 -14 01/28/2006 05:10:00 27.9 2.2 32.4 21 28 2.2 32.9 21.4 26.4 2.5 32.1 19.5 304 6 302 165 -13.9 0 -13.6 -14 01/28/2006 05:20:00 30.6 2.4 35.5 23.7 30.8 2.5 36.3 23.7 29.4 2.7 35.5 20.2 306 5 305 165 -14 0 -13.8 -14 01/28/2006 05:30:00 31 1.9 36.3 26 31.2 2 36.3 26.3 29.9 2.1 34.8 22.1 306 5 290 165 -14 0 -13.8 -14 01/28/2006 05:40:00 30.7 2.2 36.3 24 30.8 2.3 36.7 23.3 29.5 2.6 36.3 21.4 307 4 301 165 -13.9 0 -13.8 -14 01/28/2006 05:50:00 30.6 1.6 34.8 25.2 30.7 1.6 35.5 25.2 29.3 1.7 33.6 24 306 4 298 165 -13.8 0 -13.6 -14 01/28/2006 06:00:00 29.5 2 33.6 23.3 29.5 2 34 23.7 28.1 2.2 32.9 21.8 307 4 303 165 -13.7 0.1 -13.6 -13.8 01/28/2006 06:10:00 29 2.5 34.4 21.4 29 2.6 34 21.4 26.9 2.4 33.2 16.8 305 6 302 165 -13.6 0 -13.6 -13.8 01/28/2006 06:20:00 28.3 1.8 32.9 23.3 28.3 1.9 32.9 23.3 26.9 2.1 31.8 21 307 5 305 165 -13.7 0 -13.6 -13.8 01/28/2006 06:30:00 28.6 2.1 33.6 22.9 28.6 2.1 34 22.6 27.5 2.2 32.9 20.2 309 5 311 165 -13.7 0 -13.6 -13.8 01/28/2006 06:40:00 29.2 2.3 34.8 23.3 29.2 2.4 35.2 22.9 28.1 2.7 33.2 20.2 308 5 305 165 -13.6 0 -13.6 -13.8 01/28/2006 06:50:00 29.6 1.6 32.9 23.3 29.7 1.6 33.6 23.3 28.1 1.7 32.4 20.2 306 4 304 165 -13.7 0 -13.6 -13.8 01/28/2006 07:00:00 29.5 1.7 34 24 29.6 1.8 34 23.7 28 2 32.9 19.5 307 5 302 165 -13.6 0 -13.6 -13.6 01/28/2006 07:10:00 28.6 2.3 33.6 21.4 28.6 2.4 34 21 27.1 2.5 33.2 19.5 307 5 312 165 -13.5 0 -13.4 -13.6 01/28/2006 07:20:00 29.2 2.3 33.6 22.6 29.2 2.3 33.6 22.6 27.3 2.3 32.9 21.4 306 5 304 165 -13.4 0 -13.2 -13.6 01/28/2006 07:30:00 28 2.1 33.2 21 28 2.1 33.2 21 25.8 2.4 32.4 17.9 304 4 310 165 -13.4 0 -13.2 -13.6 01/28/2006 07:40:00 26.4 2.1 30.9 21 26.3 2.2 31.3 20.6 23.9 2.6 32.1 16.8 303 5 300 165 -13.5 0 -13.4 -13.6 01/28/2006 07:50:00 24.9 1.7 29.4 19.9 24.8 1.7 29.4 19.1 21.7 2.6 28.7 15.6 303 5 298 165 -13.4 0 -13.2 -13.6 01/28/2006 08:00:00 23.4 1.9 27.9 16.8 23.4 1.9 28.3 16.8 20.5 2.7 26.3 13.3 303 5 307 165 -13.3 0 -13.2 -13.6 01/28/2006 08:10:00 23.2 1.9 27.1 17.9 23.1 2 27.1 17.9 19.2 2.3 24.4 11.8 302 5 305 165 -13.1 0 -13.2 -13.6 01/28/2006 08:20:00 24.2 1.7 28.7 19.1 24.1 1.7 28.7 19.1 19.6 2.3 26 13.7 301 5 303 165 -13.1 0 -13 -13.4 01/28/2006 08:30:00 23.9 2.2 28.7 17.9 23.8 2.2 28.7 17.9 19.5 2.8 26.8 13.3 301 5 304 165 -13.1 0 -12.8 -13.2 01/28/2006 08:40:00 21.6 1.2 24.4 17.9 21.6 1.3 24.8 17.2 18.2 2.6 24.4 13.3 292 5 283 165 -13.3 0.1 -13.2 -13.6 01/28/2006 08:50:00 22 1.1 24.8 17.2 22.1 1.1 24.8 16.8 17.8 2.4 25.2 13 291 3 293 165 -13.4 0 -13.2 -13.6 01/28/2006 09:00:00 21.8 0.8 24.4 19.9 21.9 0.8 24.8 19.9 15.4 1.5 22.1 13 294 3 286 165 -13.5 0 -13.2 -13.6 01/28/2006 09:10:00 22.4 1.1 25.6 18.7 22.5 1.1 25.6 18.7 16.2 1.4 21.4 12.6 296 4 297 165 -13.3 0 -13.2 -13.6 01/28/2006 09:20:00 19.8 1.7 24 14.9 19.8 1.7 24 14.9 15.8 2 23.7 11.5 302 4 302 165 -13.2 0 -13.2 -13.4 01/28/2006 09:30:00 16.5 1.6 20.2 12.6 16.4 1.7 20.2 12.6 13.4 1.8 18.7 9.5 304 5 300 165 -13.1 0 -13 -13.4 01/28/2006 09:40:00 16.6 1.6 21 13 16.5 1.7 21 12.6 12.5 1.5 17.6 8.4 301 5 296 165 -12.6 0.2 -12.2 -13.2 01/28/2006 09:50:00 17.8 1.5 21 14.1 17.7 1.5 21 13.7 14.9 1.9 19.5 9.9 305 5 303 165 -12.4 0 -12.2 -12.6 01/28/2006 10:00:00 15.5 2 20.2 10.3 15.4 2 20.2 10.7 12.1 1.8 16.4 7.6 303 5 300 165 -12.4 0 -12.2 -12.4 01/28/2006 10:10:00 14.5 1.8 19.1 9.9 14.4 1.8 18.7 9.9 12.8 2.2 17.2 7.6 309 5 305 165 -12.2 0 -12 -12.2 01/28/2006 10:20:00 11.5 1.6 15.3 6.8 11.3 1.5 14.9 6.5 9.5 1.5 13.3 5.3 307 8 301 165 -11.9 0 -11.8 -12.2 01/28/2006 10:30:00 15.2 1.5 19.1 10.7 15.1 1.5 18.7 10.3 12 1.7 16.1 8.4 306 5 305 165 -12 0 -11.8 -12.2 01/28/2006 10:40:00 15.5 1.1 17.6 12.2 15.4 1.2 17.6 11.8 12.1 1.5 16.8 8.4 305 5 302 165 -12.3 0.1 -12 -12.4 01/28/2006 10:50:00 18.2 1.5 21.8 13.3 18.1 1.6 21.8 13 15.9 1.9 21.4 9.5 308 5 310 165 -12.4 0 -12.2 -12.4 01/28/2006 11:00:00 19.5 0.9 21 16.1 19.5 0.9 21 15.6 17.5 1.3 20.2 12.6 308 3 305 165 -12.3 0 -12.2 -12.4 01/28/2006 11:10:00 19.4 0.9 21.8 16.8 19.4 0.9 21.8 16.4 17.7 1.4 20.6 12.2 309 3 305 165 -12.4 0.1 -12.2 -12.6 01/28/2006 11:20:00 18.9 1.5 21.8 14.1 18.9 1.5 21.8 13.7 16.7 2.5 21.8 9.5 307 5 309 165 -12.4 0 -12.2 -12.6 01/28/2006 11:30:00 19.8 1.5 23.3 15.3 19.8 1.5 22.9 14.9 17.8 1.7 21.8 12.2 309 4 309 165 -12.2 0 -12 -12.4 01/28/2006 11:40:00 18.5 2.3 23.7 11.8 18.4 2.3 23.7 12.2 15.5 2.6 21.8 9.9 304 6 298 165 -11.9 0.1 -11.8 -12.2 01/28/2006 11:50:00 18.4 2 22.9 13 18.3 2.1 22.9 13 14.7 2 19.9 9.5 303 6 302 165 -11.9 0 -11.6 -12 01/28/2006 12:00:00 18.8 1.8 22.6 13.7 18.7 1.9 22.6 14.1 14.3 1.7 19.5 9.5 302 5 303 165 -11.8 0 -11.6 -11.8 01/28/2006 12:10:00 19.3 1.8 23.3 13.7 19.2 1.8 23.3 13.7 16 2.5 22.6 10.7 305 5 306 165 -11.8 0 -11.6 -11.8 01/28/2006 12:20:00 19.4 1.4 22.1 15.6 19.3 1.4 22.1 15.3 16.2 2 21.4 10.7 306 5 310 165 -11.8 0 -11.8 -11.8 01/28/2006 12:30:00 19.5 1.4 22.6 15.3 19.5 1.4 22.6 15.3 16 2 21 10.7 305 5 301 165 -11.8 0 -11.6 -11.8 01/28/2006 12:40:00 18.2 1.5 21.4 13.3 18.1 1.6 21.4 13.3 14.8 2 19.9 10.3 305 6 304 165 -11.7 0 -11.4 -11.8 01/28/2006 12:50:00 17.8 2.3 21.8 12.2 17.7 2.3 21.4 11.8 15 2.1 20.6 9.1 305 6 304 165 -11.6 0 -11.4 -11.8 01/28/2006 13:00:00 17.2 2.1 22.1 13 17.2 2.1 21.8 13 14.5 2.6 21.8 8.4 305 6 300 165 -11.6 0 -11.4 -11.8 01/28/2006 13:10:00 16.2 1.9 20.6 11.1 16.2 2 20.6 10.7 13 2 20.6 8.8 303 7 302 165 -11.7 0.1 -11.4 -11.8 01/28/2006 13:20:00 17.8 2.1 21.8 11.8 17.7 2.2 21.8 11.5 13.6 1.7 18.3 9.1 300 6 297 165 -11.8 0.1 -11.6 -12 01/28/2006 13:30:00 16.7 2.1 20.6 11.1 16.7 2.1 20.6 11.5 12.8 2 18.7 7.2 303 5 308 165 -11.8 0 -11.6 -11.8 01/28/2006 13:40:00 14.4 1.8 17.9 9.9 14.4 1.9 18.3 9.5 11.7 1.9 16.8 7.2 305 7 298 165 -11.7 0 -11.4 -11.8 01/28/2006 13:50:00 13.8 2.4 19.1 8.8 13.7 2.4 18.7 9.1 11.2 2 16.8 7.6 305 7 295 165 -11.5 0 -11.4 -11.8 01/28/2006 14:00:00 14.1 1.7 17.6 8.8 14.1 1.7 17.9 8.8 11.1 1.9 16.4 7.2 299 7 291 165 -11.5 0 -11.4 -11.6 01/28/2006 14:10:00 13.9 1.4 17.2 9.5 13.8 1.4 17.2 9.5 10.1 1.3 14.1 6.1 299 6 304 165 -11.5 0 -11.4 -11.8 01/28/2006 14:20:00 13.3 1.7 17.6 9.1 13.2 1.7 17.2 8.8 10.2 1.8 15.6 6.8 296 7 295 165 -11.7 0 -11.4 -11.8 01/28/2006 14:30:00 12 2.3 16.4 6.8 11.9 2.3 16.4 6.1 9.3 1.7 13.7 4.9 299 8 303 165 -11.5 0 -11.4 -11.8 01/28/2006 14:40:00 12 1.9 16.4 7.2 11.9 1.9 16.1 7.2 9.5 1.8 13.7 5.3 305 7 303 165 -11.4 0 -11.4 -11.6 01/28/2006 14:50:00 10.9 2.3 15.3 6.1 10.8 2.3 15.6 5.7 8.6 1.7 13 4.2 305 7 297 165 -11.4 0 -11.2 -11.4 01/28/2006 15:00:00 11.9 1 15.3 9.1 11.8 1 15.3 9.5 8.8 1.5 14.1 6.1 303 6 294 165 -11.4 0 -11.4 -11.4 01/28/2006 15:10:00 9.9 1.7 13 4.2 9.8 1.7 13 4.2 7.9 1.5 12.2 3.8 303 7 306 165 -11.4 0 -11.4 -11.6 01/28/2006 15:20:00 9.3 1.5 13 6.1 9.2 1.5 12.6 5.7 7.4 1.3 11.5 4.2 305 6 296 165 -11.5 0 -11.4 -11.6 01/28/2006 15:30:00 8.9 1.2 14.5 6.5 8.8 1.2 13.7 6.5 6.9 1.2 11.8 4.2 303 6 304 165 -11.5 0 -11.4 -11.6 01/28/2006 15:40:00 9.4 1.5 12.6 6.1 9.3 1.5 12.6 6.1 7 1.1 11.1 4.6 303 5 315 165 -11.5 0 -11.4 -11.8 01/28/2006 15:50:00 11.5 1.1 14.1 8.8 11.4 1.1 14.1 8.4 8 1.3 12.2 5.3 298 4 296 165 -11.6 0 -11.4 -11.8 01/28/2006 16:00:00 9.8 1 12.2 6.8 9.6 0.9 11.5 6.8 7.1 1 9.9 4.6 303 5 298 165 -11.7 0.1 -11.4 -11.8 01/28/2006 16:10:00 9.4 1.1 11.8 6.5 9.3 1.1 12.2 6.5 7 1.1 10.3 4.2 301 6 304 165 -11.8 0 -11.6 -11.8 01/28/2006 16:20:00 9.1 1 11.5 6.1 9 1 11.5 5.7 6.7 1.1 10.7 3.8 299 6 285 165 -11.9 0 -11.8 -11.8 01/28/2006 16:30:00 8.3 0.8 9.9 5.7 8.1 0.8 9.9 5.7 6.1 0.9 8.8 4.2 301 6 305 165 -11.8 0 -11.6 -12 01/28/2006 16:40:00 8.6 1 10.3 5.3 8.5 1 9.9 5.3 6.3 0.9 9.1 4.2 302 6 307 165 -11.9 0 -11.8 -12.2 01/28/2006 16:50:00 7.9 0.9 10.7 5.7 7.8 1 10.7 5.7 6.8 1 9.5 4.2 309 5 315 165 -12 0 -11.8 -12.2 01/28/2006 17:00:00 5.9 1.1 8.4 4.2 5.7 1.2 8.8 3.8 5.4 0.9 8.4 3.8 315 13 313 165 -11.9 0.1 -11.8 -12.2 01/28/2006 17:10:00 6 0.7 7.6 4.2 5.9 0.7 8 4.2 5.2 0.6 7.2 3.8 309 9 298 165 -12 0 -11.8 -12.2 01/28/2006 17:20:00 5.4 0.9 7.6 3.4 5.3 0.9 7.2 3.4 4.9 0.8 7.2 3.4 315 11 306 165 -12.1 0 -11.8 -12.2 01/28/2006 17:30:00 4.7 0.7 6.5 2.6 4.5 0.7 6.5 2.3 4.1 0.7 6.1 2.6 310 8 318 165 -12 0.1 -11.8 -12.4 01/28/2006 17:40:00 6.9 1.1 10.3 4.9 6.8 1.2 10.3 4.9 6.3 1.4 9.5 3.4 321 15 342 165 -12.4 0 -12.2 -12.6 01/28/2006 17:50:00 7.5 1.1 9.9 5.3 7.4 1.1 9.9 4.9 7.4 1.1 10.7 4.6 331 8 327 165 -12.1 0 -12 -12.4 01/28/2006 18:00:00 8.4 0.9 10.7 5.7 8.3 0.9 11.1 5.7 8.2 0.9 10.7 5.3 332 7 332 165 -12.1 0 -12 -12.2 01/28/2006 18:10:00 7.9 1 10.3 5.7 7.9 1.1 10.7 4.9 7.8 1.1 10.3 5.3 336 8 349 165 -12 0 -11.8 -12.2 01/28/2006 18:20:00 7.9 0.8 9.5 5.3 7.8 0.9 9.9 5.3 7.7 0.8 9.5 5.7 337 8 342 165 -12 0 -11.8 -12.2 01/28/2006 18:30:00 7 0.9 9.9 4.9 6.7 1.1 9.9 3.4 6.8 1.1 9.5 4.2 338 12 344 165 -12.1 0 -12 -12.2 01/28/2006 18:40:00 6 1.1 9.9 3.8 5.7 1.1 10.3 3.8 5.8 1 9.9 3.8 333 11 344 165 -12.1 0 -11.8 -12.2 01/28/2006 18:50:00 4.9 0.6 6.5 3 4.8 0.6 6.1 2.6 4.7 0.6 6.1 2.6 316 10 305 165 -12.2 0 -12 -12.4 01/28/2006 19:00:00 6.2 1 8.4 3.8 6.1 1 8.4 3.8 5.1 0.8 7.6 3 304 11 285 165 -12.1 0.1 -12 -12.4 01/28/2006 19:10:00 6.2 0.7 8 4.2 6 0.7 7.6 3.8 5.5 0.8 7.6 3.4 310 10 322 165 -12 0 -11.8 -12.2 01/28/2006 19:20:00 5.1 0.7 7.6 3.8 4.9 0.7 7.2 3.8 4.8 0.6 6.5 3 317 13 300 165 -11.9 0 -11.8 -12.2 01/28/2006 19:30:00 5 0.7 6.8 3.4 4.8 0.8 6.8 3 4.6 0.6 6.5 3 317 12 312 165 -11.9 0 -11.8 -12.2 01/28/2006 19:40:00 4.4 0.6 6.1 3 4.3 0.6 6.1 3 4.3 0.6 6.5 2.6 308 21 290 165 -11.9 0 -11.8 -12.2 01/28/2006 19:50:00 4.6 0.5 6.1 3 4.4 0.5 5.7 3 4.4 0.5 5.7 3 323 13 354 165 -12.1 0 -11.8 -12.4 01/28/2006 20:00:00 5 0.5 6.1 3.8 4.8 0.5 6.1 3 5.1 0.5 6.1 3.8 326 9 301 165 -12.2 0 -12 -12.4 01/28/2006 20:10:00 4.6 0.7 6.5 2.6 4.4 0.7 6.5 2.3 4 0.6 5.3 2.3 314 13 298 165 -12 0 -11.8 -12.2 01/28/2006 20:20:00 5.6 0.7 7.2 3.8 5.4 0.7 6.8 3.8 4.9 0.7 6.8 3 308 8 294 165 -12.1 0 -11.8 -12.2 01/28/2006 20:30:00 5.2 0.7 6.8 3.4 5 0.7 6.5 3.4 4.9 0.6 6.5 3 314 9 300 165 -12.1 0 -11.8 -12.2 01/28/2006 20:40:00 5.2 0.6 7.2 3.4 5 0.6 7.2 3 4.5 0.7 6.1 2.3 309 8 305 165 -12.1 0 -12 -12.4 01/28/2006 20:50:00 4.5 0.5 5.7 3.4 4.3 0.5 5.7 3 4.2 0.5 5.7 2.6 314 9 310 165 -12.1 0 -11.8 -12.2 01/28/2006 21:00:00 4.4 0.6 5.7 2.6 4.3 0.6 5.7 2.6 3.8 0.6 5.7 1.9 307 9 300 165 -12.1 0 -11.8 -12.2 01/28/2006 21:10:00 4.9 0.7 6.8 3 4.7 0.7 6.8 3 4.4 0.6 6.1 2.6 307 9 293 165 -12 0.1 -11.8 -12.4 01/28/2006 21:20:00 4.7 0.7 6.5 2.6 4.4 0.7 6.5 2.6 4.3 0.6 6.1 3 317 13 343 165 -11.9 0.1 -11.8 -12.2 01/28/2006 21:30:00 5.8 0.7 7.6 4.2 5.7 0.8 7.2 3.8 4.9 0.7 6.8 3.4 306 8 295 165 -11.9 0 -11.8 -12 01/28/2006 21:40:00 6.7 1 9.5 4.2 6.6 1 9.5 4.2 5.6 0.8 8.4 3.4 304 9 305 165 -11.9 0 -11.8 -12 01/28/2006 21:50:00 6.4 1 8.8 4.2 6.2 1 8.8 3.8 5.5 0.9 9.1 3.4 308 12 295 165 -12 0 -11.8 -12.2 01/28/2006 22:00:00 5.5 0.5 6.8 4.2 5.4 0.5 6.8 4.2 5.2 0.6 6.8 3.4 318 9 306 165 -12.1 0 -11.8 -12.2 01/28/2006 22:10:00 5.9 1 9.1 4.2 5.8 1 8.8 3.8 5.3 0.8 7.6 3.8 310 11 307 165 -12 0 -11.8 -12.2 01/28/2006 22:20:00 7.1 0.5 8.4 5.7 7 0.5 8.4 5.3 6.4 0.7 8 4.6 312 6 302 165 -12 0 -11.8 -12.2 01/28/2006 22:30:00 6 0.8 8.4 4.2 5.8 0.8 8.8 3.8 5.9 0.6 7.6 4.6 325 11 315 165 -12.2 0 -12 -12.4 01/28/2006 22:40:00 7 0.7 8.4 4.9 6.5 1.1 8.4 3 6.8 0.6 8.4 4.9 327 19 312 165 -12.2 0 -12 -12.4 01/28/2006 22:50:00 6.8 0.8 9.1 4.6 6.3 1.1 9.5 3.4 7 0.8 9.9 4.6 343 10 349 165 -12 0 -11.8 -12.2 01/28/2006 23:00:00 6.9 1.1 9.5 3.8 6.3 1.3 9.5 3.4 7.2 1 9.9 4.9 348 9 347 165 -11.9 0.1 -11.6 -12.2 01/28/2006 23:10:00 7.2 1.1 9.5 3.8 5.7 1.5 9.1 2.6 7.7 1 9.9 4.9 356 8 350 165 -11.9 0 -11.8 -12 01/28/2006 23:20:00 8.7 0.9 11.1 5.3 8.3 1.3 11.5 4.2 9 0.8 10.7 5.7 347 6 343 165 -11.9 0 -11.8 -12 01/28/2006 23:30:00 8 1 9.9 5.3 7.9 1.1 10.3 5.3 8.3 1 10.3 5.7 342 8 353 165 -11.9 0 -11.8 -12 01/28/2006 23:40:00 8.6 0.8 11.1 6.1 7.4 1.3 10.7 4.6 8.9 0.9 11.1 6.8 351 6 355 165 -11.8 0 -11.6 -11.8 01/28/2006 23:50:00 8.2 1 10.3 5.3 7.5 1.1 9.5 4.2 8.7 1 11.1 5.7 349 6 354 165 -11.8 0 -11.6 -11.8 01/29/2006 00:00:00 8.5 0.9 11.1 5.7 7.9 1.5 11.1 3.4 8.6 0.9 11.1 5.3 347 8 358 165 -11.8 0 -11.6 -11.8 01/29/2006 00:10:00 9.1 1 11.8 6.5 7.8 1.7 11.8 3.4 9.3 1 11.8 6.8 351 7 2 165 -11.7 0 -11.6 -11.8 01/29/2006 00:20:00 9 0.8 10.7 6.1 8.7 1.2 11.1 4.6 9.2 0.8 10.7 6.5 346 6 342 165 -11.7 0 -11.6 -11.8 01/29/2006 00:30:00 9.5 0.9 11.5 6.5 9.3 1.2 11.8 4.9 9.6 0.9 11.1 6.8 347 5 349 165 -11.8 0 -11.6 -11.8 01/29/2006 00:40:00 8.8 1 10.7 5.7 8.1 1.3 11.1 4.6 8.9 1 11.8 6.5 349 6 352 165 -11.8 0 -11.8 -11.8 01/29/2006 00:50:00 9.2 0.8 12.6 7.2 8.8 1.3 12.6 4.9 9.4 0.8 11.8 7.2 347 5 344 165 -11.9 0 -11.8 -12 01/29/2006 01:00:00 8.8 0.8 10.7 6.8 8.4 1.2 11.1 4.6 9 1 11.1 5.7 349 5 359 165 -11.9 0 -11.8 -12 01/29/2006 01:10:00 10 1 13 7.2 10 1.1 13.3 6.5 9.9 1 13.3 8 342 5 341 165 -11.9 0 -11.8 -12 01/29/2006 01:20:00 11.2 1 14.1 8.8 11.3 1.3 14.5 6.8 11.3 1.1 14.5 8 342 5 345 165 -11.9 0 -11.8 -12.2 01/29/2006 01:30:00 10.7 0.9 13.7 8.8 10.8 1.1 14.1 7.6 10.7 1 13.7 8.4 342 5 347 165 -11.9 0 -11.8 -12.2 01/29/2006 01:40:00 8.9 1.5 13 5.7 8.4 2 13.3 3.8 9 1.5 13 5.3 345 9 343 165 -11.7 0 -11.4 -12 01/29/2006 01:50:00 7.5 1.1 9.9 4.6 7.4 1.2 10.3 4.2 7.4 1.2 10.7 4.6 340 8 343 165 -11.6 0 -11.4 -11.8 01/29/2006 02:00:00 8.2 1.2 11.1 4.2 8 1.5 11.8 3.8 8.1 1.2 11.5 4.6 341 10 349 165 -11.5 0 -11.4 -11.6 01/29/2006 02:10:00 7.5 1.3 10.7 4.6 7.3 1.2 10.3 4.2 7.4 1.3 10.3 4.6 337 11 336 165 -11.4 0 -11.4 -11.6 01/29/2006 02:20:00 7.5 1.2 10.3 4.2 7.1 1.3 9.9 3.8 7.3 1.2 10.7 4.2 342 9 343 165 -11.4 0 -11.4 -11.4 01/29/2006 02:30:00 6.1 0.7 8 4.2 5.9 0.7 8 3.4 6.1 0.8 8.4 4.2 326 13 332 165 -11.3 0 -11.4 -11.4 01/29/2006 02:40:00 5.8 0.7 8 4.2 5.5 0.8 8 3 5.6 0.6 7.6 3.8 329 14 354 165 -11.3 0 -11.4 -11.4 01/29/2006 02:50:00 6.5 1 8.8 4.2 6.3 1 8.4 3.8 5.5 0.8 8 3.4 312 10 302 165 -11.4 0 -11.2 -11.6 01/29/2006 03:00:00 6.8 0.7 8.4 5.3 6.7 0.7 8.4 4.9 5.9 1 8.4 3 310 11 316 165 -11.5 0 -11.4 -11.6 01/29/2006 03:10:00 6.5 0.7 8 4.9 6.3 0.7 8.4 4.6 5.4 0.8 7.6 3 307 12 288 165 -11.4 0 -11.4 -11.4 01/29/2006 03:20:00 6.3 1 9.5 4.2 6.1 1 9.1 4.2 5.5 1.1 8.8 3.4 305 13 328 165 -11.3 0 -11.2 -11.4 01/29/2006 03:30:00 8.4 1.2 11.5 5.3 8.3 1.3 11.8 5.3 8.4 1.2 11.5 5.3 338 9 346 165 -11.1 0.1 -11 -11.4 01/29/2006 03:40:00 9.7 0.9 11.8 7.6 9.7 1.2 12.2 4.9 9.6 1.1 12.2 6.8 343 7 339 165 -11 0 -11 -11.2 01/29/2006 03:50:00 9.4 1.1 13 6.8 9.2 1.5 13.3 3.8 9.6 1.2 13.7 7.2 344 7 350 165 -11.2 0.1 -11 -11.4 01/29/2006 04:00:00 9.6 1 11.8 7.6 9.6 1.1 12.6 5.3 9.6 1.1 11.8 7.2 341 6 341 165 -11.3 0 -11.2 -11.4 01/29/2006 04:10:00 8.3 0.9 11.5 6.1 8.2 1 11.5 4.9 8.1 0.9 11.1 6.1 337 10 341 165 -11.4 0 -11.4 -11.4 01/29/2006 04:20:00 9 0.9 11.1 6.5 8.9 1 11.5 6.5 8.9 1.3 12.2 5.3 329 12 343 165 -11.3 0 -11 -11.6 01/29/2006 04:30:00 7.6 1.1 10.3 4.9 7.5 1.1 10.3 4.6 6.5 1.1 9.9 2.6 311 9 302 165 -11.4 0 -11.2 -11.6 01/29/2006 04:40:00 6.7 1.1 9.5 3.8 6.5 1.1 9.9 3.4 6.2 1.2 9.5 3.8 326 15 349 165 -11.3 0.1 -11.2 -11.6 01/29/2006 04:50:00 7.9 1 9.9 5.3 7.8 0.9 9.9 5.3 6.6 1.2 9.9 4.2 302 15 337 165 -11.3 0 -11 -11.4 01/29/2006 05:00:00 6.9 1 9.5 4.2 6.8 1 9.5 3.8 6 1.1 8.8 3.4 296 10 285 165 -11.3 0 -11 -11.4 01/29/2006 05:10:00 6.9 1 10.7 4.6 6.8 1 10.3 4.2 6.1 1.1 9.1 2.6 299 11 298 165 -11.1 0.1 -10.8 -11.4 01/29/2006 05:20:00 7.3 1 9.9 3.8 7.2 1 9.5 3.8 6.4 1.1 8.8 3.4 297 10 297 165 -11.3 0 -11.2 -11.4 01/29/2006 05:30:00 7.1 1 10.3 4.9 7 1 10.3 4.9 6 1.1 9.9 3.8 302 10 309 165 -11.2 0.1 -11 -11.4 01/29/2006 05:40:00 7 1 9.9 3.8 6.9 1 9.9 3.8 5.7 1.1 9.5 3 306 12 335 165 -11.3 0 -11 -11.4 01/29/2006 05:50:00 6.9 1 9.9 4.6 6.7 1 9.9 4.6 5.9 1.2 9.5 3.4 309 12 339 165 -11.1 0 -10.8 -11.4 01/29/2006 06:00:00 6.2 1.2 9.5 2.3 6.1 1.2 9.9 2.6 5.2 1.1 9.5 2.3 307 14 293 165 -11.1 0.1 -10.8 -11.4 01/29/2006 06:10:00 6.2 1.1 10.3 3.8 6.1 1.1 10.7 3.8 5.5 1.1 9.9 3.4 310 11 339 165 -11 0 -10.8 -11.2 01/29/2006 06:20:00 6.6 0.8 9.1 4.2 6.3 0.9 9.1 3.8 6.1 1 9.5 3.4 321 17 332 165 -11 0.1 -10.6 -11.4 01/29/2006 06:30:00 5.8 0.8 8.8 3.8 5.6 0.8 8 3.4 5.5 0.8 8 3 327 15 355 165 -10.8 0.1 -10.6 -11 01/29/2006 06:40:00 5.2 0.9 7.6 2.6 5.1 1 7.2 1.9 4.9 0.9 7.2 2.6 319 17 310 165 -10.8 0 -10.6 -11 01/29/2006 06:50:00 5 1.1 8.4 2.3 4.7 1.2 8 1.9 4.8 1.2 7.6 2.3 328 16 325 165 -10.7 0 -10.6 -11 01/29/2006 07:00:00 5.7 0.9 8.4 3.4 5.5 0.9 8.4 3.8 5.4 1 8.4 2.3 323 15 358 165 -10.5 0.1 -10.2 -10.8 01/29/2006 07:10:00 5.9 0.6 8.4 3.8 5.7 0.7 8.4 3.8 5.2 0.8 6.8 3 313 11 307 165 -10.5 0 -10.4 -10.6 01/29/2006 07:20:00 5.8 0.8 8 3.8 5.6 0.8 7.6 3.4 4.7 0.8 6.8 3 302 10 304 165 -10.5 0 -10.4 -10.8 01/29/2006 07:30:00 5.2 0.8 7.6 3.4 5 0.8 7.2 3 4.4 0.9 6.8 2.6 309 9 306 165 -10.7 0 -10.6 -11 01/29/2006 07:40:00 5.6 1 8.8 3 5.5 1 8.8 3 4.5 0.9 8.8 2.6 305 9 313 165 -10.8 0 -10.6 -11 01/29/2006 07:50:00 4.8 0.8 7.2 3 4.7 0.8 6.8 2.6 4 0.7 6.5 2.6 307 10 321 165 -10.7 0 -10.6 -11 01/29/2006 08:00:00 4.7 0.8 7.2 3 4.6 0.8 6.8 3 4.3 0.6 6.5 2.6 313 12 291 165 -10.8 0 -10.8 -11 01/29/2006 08:10:00 5.6 0.8 7.2 3.4 5.5 0.8 7.2 3 4.6 0.9 6.5 2.3 299 9 291 165 -10.8 0.1 -10.6 -11 01/29/2006 08:20:00 4.8 0.7 6.8 2.6 4.8 0.7 6.5 2.3 3.9 0.8 5.7 1.5 298 11 302 165 -10.7 0 -10.6 -10.8 01/29/2006 08:30:00 6.2 0.6 8 4.6 6.1 0.6 8 4.6 4.5 0.6 7.2 3 299 6 298 165 -10.8 0 -10.6 -10.8 01/29/2006 08:40:00 5.1 0.7 6.8 2.6 5 0.7 6.8 2.3 4 0.8 6.1 2.3 292 9 313 165 -10.8 0 -10.6 -11 01/29/2006 08:50:00 6 0.6 7.2 4.6 5.9 0.6 7.2 4.2 4.7 0.8 7.2 3 293 6 293 165 -10.7 0 -10.6 -11 01/29/2006 09:00:00 6.9 0.9 8.8 4.2 6.8 0.9 8.8 4.2 5.6 1.2 8.8 3 291 7 285 165 -10.7 0 -10.6 -10.8 01/29/2006 09:10:00 6.5 0.8 8.4 3.4 6.4 0.8 8 3.4 5 0.9 7.6 3 295 7 296 165 -10.7 0 -10.6 -10.8 01/29/2006 09:20:00 7.4 0.7 9.1 4.6 7.3 0.7 9.1 5.3 5.7 0.9 8 3.4 293 6 296 165 -10.6 0 -10.4 -10.8 01/29/2006 09:30:00 6.7 1 9.5 4.2 6.6 1 8.8 3.8 5.2 1 8.4 3.4 296 8 287 165 -10.4 0 -10.2 -10.6 01/29/2006 09:40:00 6.7 1 8.4 3.4 6.6 1 8.4 3.4 5.5 1 8 2.6 293 6 295 165 -10.3 0 -10.2 -10.6 01/29/2006 09:50:00 7.2 1 9.5 3.8 7.1 1 9.1 3.8 5.7 1 8.4 2.3 294 8 300 165 -10.2 0 -10 -10.2 01/29/2006 10:00:00 7.2 0.7 9.1 4.9 7.1 0.7 9.1 4.9 6 0.9 8.4 3.8 291 4 298 165 -10.2 0 -10.2 -10.4 01/29/2006 10:10:00 7.3 0.8 9.1 4.9 7.2 0.8 8.8 4.9 5.6 1 8.4 3 294 5 290 165 -10.2 0 -10 -10.2 01/29/2006 10:20:00 7.6 0.6 9.9 6.1 7.5 0.6 9.5 6.1 5.4 0.9 8.8 3.4 296 4 293 165 -10.2 0 -10 -10.4 01/29/2006 10:30:00 7.1 0.6 8.4 5.3 7 0.6 8.4 5.3 5 0.7 7.2 3.4 301 4 294 165 -10 0.1 -9.7 -10.2 01/29/2006 10:40:00 6.6 0.5 8 5.3 6.5 0.5 8 4.9 4.6 0.6 6.1 3 301 4 300 165 -9.7 0 -9.7 -9.7 01/29/2006 10:50:00 6 0.6 7.6 4.6 6 0.6 7.2 4.2 4.2 0.5 5.7 3 301 3 296 165 -9.4 0.2 -9.1 -9.7 01/29/2006 11:00:00 6.1 0.4 7.6 4.6 6 0.4 7.6 4.6 4.4 0.7 6.1 3 297 5 297 165 -9.2 0 -8.9 -9.3 01/29/2006 11:10:00 5.8 0.8 8.8 4.2 5.7 0.8 8.8 3.8 4.9 1.1 8 2.6 297 10 288 165 -9.1 0 -8.9 -9.3 01/29/2006 11:20:00 6.5 1 8.4 3.4 6.4 1 8.4 3.8 5 1 7.6 2.6 301 9 302 165 -9.1 0 -8.9 -9.1 01/29/2006 11:30:00 7.2 0.8 9.5 4.9 7.1 0.8 9.5 4.6 5.7 1 8.8 3.4 305 11 332 165 -9.1 0 -8.9 -9.3 01/29/2006 11:40:00 7.3 0.8 9.5 4.9 7.2 0.8 9.5 5.3 5.6 1 8.8 3.4 305 8 304 165 -9.2 0 -9.1 -9.3 01/29/2006 11:50:00 7.7 0.8 9.9 4.6 7.6 0.8 9.5 4.9 5.8 0.8 8.4 3.8 302 6 307 165 -9.2 0 -9.1 -9.3 01/29/2006 12:00:00 7.4 0.8 9.5 4.9 7.3 0.8 9.1 5.3 5.7 0.8 8.8 4.2 303 7 308 165 -9 0.2 -8.5 -9.3 01/29/2006 12:10:00 7.3 0.8 9.9 5.3 7.1 0.8 9.5 4.9 5.8 0.9 8 3.4 305 8 305 165 -8.4 0 -8.3 -8.7 01/29/2006 12:20:00 7.8 1.2 11.1 5.7 7.7 1.2 10.7 5.3 6.3 1 9.5 3.8 304 8 305 165 -8.5 0.1 -8.3 -8.5 01/29/2006 12:30:00 7.4 0.8 9.9 5.3 7.3 0.8 9.9 5.3 5.9 1.1 9.5 3.8 301 9 295 165 -8.4 0.2 -8.1 -8.7 01/29/2006 12:40:00 6.5 0.7 8.4 4.6 6.4 0.7 8.4 4.6 5.5 0.9 8.4 3.4 302 9 304 165 -7.9 0.2 -7.4 -8.3 01/29/2006 12:50:00 6.3 1 9.1 3.8 6.2 1 8.8 3.4 5.4 1 9.1 3.4 302 10 293 165 -8 0 -7.6 -8.3 01/29/2006 13:00:00 6.9 0.8 9.5 4.9 6.8 0.8 9.1 4.6 5.7 1 8.4 3.8 307 9 299 165 -8 0.3 -7.2 -8.3 01/29/2006 13:10:00 6.3 0.9 9.1 4.2 6.2 0.9 8.8 4.2 5.3 0.8 7.6 3.4 309 10 300 165 -7.3 0.2 -6.8 -7.9 01/29/2006 13:20:00 7.2 0.7 9.5 5.7 7.2 0.6 9.5 5.7 5.4 0.8 8.4 3.8 302 6 300 165 -7.9 0 -7.6 -8.1 01/29/2006 13:30:00 6.7 0.9 9.9 4.2 6.7 0.9 10.3 4.2 5.6 1 9.1 3.4 307 11 285 165 -7.7 0.2 -7.2 -8.1 01/29/2006 13:40:00 6.6 0.8 9.5 4.6 6.6 0.8 9.1 4.6 6 0.8 8.4 3.8 309 11 294 165 -7.6 0.1 -7.2 -7.9 01/29/2006 13:50:00 6.1 1 9.1 4.2 6.1 1 9.5 4.2 5.3 0.9 9.5 3.4 304 9 290 165 -7.4 0 -7.2 -7.6 01/29/2006 14:00:00 5.3 1.3 8.4 0.4 5.2 1.3 8 0.4 4.5 1.3 8.8 1.1 308 16 309 165 -7.1 0.3 -6.4 -7.4 01/29/2006 14:10:00 5.4 1 8 3 5.3 0.9 7.6 3.4 4.6 0.9 7.6 3 306 12 282 165 -7.1 0 -6.6 -7.2 01/29/2006 14:20:00 6.1 0.8 8.4 4.2 6.1 0.8 8.8 4.2 5.3 1 9.1 3 308 11 308 165 -7.1 0 -6.8 -7.2 01/29/2006 14:30:00 6 0.6 8 4.6 6 0.6 7.6 4.6 5.3 1 8 3.4 310 9 310 165 -6.9 0.1 -6.6 -7.2 01/29/2006 14:40:00 5.2 0.8 8 3.4 5.2 0.8 7.6 3.4 4.7 1.1 9.1 2.6 303 13 296 165 -7.3 0 -7 -7.6 01/29/2006 14:50:00 5.9 0.7 7.6 3.8 5.8 0.7 7.2 4.2 5.1 0.7 7.2 3.4 307 8 302 165 -7.9 0.2 -7.2 -8.1 01/29/2006 15:00:00 5.1 0.9 7.6 3 5.1 0.9 7.6 2.6 4.4 0.6 6.8 2.6 307 9 295 165 -8.1 0.1 -7.6 -8.3 01/29/2006 15:10:00 4.1 0.7 5.7 2.3 4.1 0.7 5.7 2.3 3.6 0.7 5.3 1.9 314 13 302 165 -7.9 0.1 -7.4 -8.1 01/29/2006 15:20:00 4.3 0.6 5.7 2.3 4.3 0.5 5.7 2.6 4.1 0.6 5.3 2.3 316 9 328 165 -8.1 0 -8.1 -8.3 01/29/2006 15:30:00 4.2 0.6 6.1 2.6 4.1 0.6 5.7 3 4 0.6 5.7 1.9 333 10 331 165 -8.2 0 -8.1 -8.3 01/29/2006 15:40:00 5.8 1.3 10.3 2.6 5.7 1.2 9.5 2.6 5.5 1.4 9.1 2.3 332 12 347 165 -8.3 0.1 -8.1 -8.5 01/29/2006 15:50:00 5.5 0.7 7.6 3.4 5.4 0.8 8 3.4 5.5 0.7 8 3.4 336 13 343 165 -8.5 0 -8.3 -8.5 01/29/2006 16:00:00 5.6 0.7 8 3.4 5.5 0.7 8.4 3 5.2 0.8 8.4 3 320 13 328 165 -8.4 0 -8.3 -8.5 01/29/2006 16:10:00 6.2 1.3 9.1 2.6 6.1 1.3 9.1 2.6 5.5 1.3 9.5 2.6 311 13 306 165 -8.2 0.1 -8.1 -8.5 01/29/2006 16:20:00 7.3 1.2 10.3 4.6 7.2 1.2 9.9 4.6 6.8 1.2 9.9 4.2 320 10 304 165 -8.1 0 -8.1 -8.3 01/29/2006 16:30:00 7.3 0.9 9.1 4.9 7.2 0.9 9.1 4.9 6.2 0.9 9.1 3.4 308 7 307 165 -8 0 -7.9 -8.1 01/29/2006 16:40:00 6 1 8.8 3 5.9 1 8.8 2.6 5.2 0.8 8.4 3 310 8 310 165 -8.2 0 -8.1 -8.5 01/29/2006 16:50:00 5.4 0.9 7.2 2.3 5.3 0.9 7.2 2.3 4.8 0.8 6.8 3 308 11 301 165 -8.5 0.1 -8.3 -8.7 01/29/2006 17:00:00 5.5 0.6 7.2 3.8 5.4 0.6 7.2 3.8 4.9 0.7 6.8 3 313 8 310 165 -8.8 0 -8.5 -8.9 01/29/2006 17:10:00 4.5 0.6 5.7 3.4 4.4 0.6 5.7 3 4.2 0.7 5.7 2.6 318 9 328 165 -8.9 0 -8.7 -8.9 01/29/2006 17:20:00 5.4 0.7 7.6 4.2 5.3 0.7 7.6 3.8 5 0.8 7.6 3 317 10 308 165 -8.8 0 -8.5 -8.9 01/29/2006 17:30:00 5.2 1 7.6 3.4 4.9 1.1 8 2.3 4.9 0.9 7.6 2.6 339 11 344 165 -8.8 0 -8.5 -8.9 01/29/2006 17:40:00 5.7 1.3 9.5 3 5.6 1.3 9.1 2.3 5.1 1 8.4 3 318 16 306 165 -8.7 0 -8.5 -8.9 01/29/2006 17:50:00 7 0.9 9.5 4.6 6.9 0.9 9.1 4.9 6.4 0.9 8.8 3.4 313 10 309 165 -8.5 0 -8.3 -8.7 01/29/2006 18:00:00 7.8 1.2 12.2 5.3 7.6 1.3 11.8 4.2 7.2 1.3 10.7 4.6 323 19 318 165 -8.6 0 -8.5 -8.7 01/29/2006 18:10:00 8.2 1.2 12.2 5.3 8.1 1.3 12.6 5.3 7.4 1.2 11.1 4.6 313 10 302 165 -8.5 0 -8.3 -8.7 01/29/2006 18:20:00 7.8 1.2 13 5.3 7.7 1.2 13 4.6 6.6 1.5 11.8 4.2 301 13 292 165 -8.3 0 -8.1 -8.5 01/29/2006 18:30:00 7.1 1 11.5 4.6 7.1 1 11.5 4.6 5.6 1 9.5 3.4 305 9 295 165 -8.5 0 -8.3 -8.5 01/29/2006 18:40:00 6.7 0.9 9.1 4.6 6.7 0.9 9.1 4.2 5.4 1 8 3 306 10 304 165 -8.6 0 -8.5 -8.7 01/29/2006 18:50:00 6 1 8.4 3.8 5.9 1 8 3.8 5.4 0.7 7.6 3.4 315 11 308 165 -8.8 0 -8.5 -8.9 01/29/2006 19:00:00 6.3 1 8.8 3.4 6.2 1 9.1 3.4 5.2 1 7.2 2.3 306 6 307 165 -8.7 0 -8.5 -8.9 01/29/2006 19:10:00 6.7 0.8 9.5 4.6 6.6 0.8 9.5 4.2 6.1 1 8 4.2 314 8 312 165 -8.7 0 -8.5 -8.9 01/29/2006 19:20:00 6.8 0.8 8.8 4.6 6.7 0.8 8.8 4.9 5.1 0.8 7.6 3.4 304 6 309 165 -8.7 0 -8.5 -8.9 01/29/2006 19:30:00 5.7 0.9 8.4 3.4 5.6 0.9 8.4 3.4 4.6 1.2 8.4 2.6 309 14 318 165 -8.8 0 -8.5 -8.9 01/29/2006 19:40:00 6.4 0.5 7.6 4.9 6.3 0.5 7.6 4.9 5 0.8 7.2 3.4 303 7 306 165 -9 0 -8.9 -9.1 01/29/2006 19:50:00 5.6 0.6 7.2 3.8 5.5 0.6 7.2 3.8 4.6 0.6 6.8 3 307 4 310 165 -8.7 0 -8.5 -8.9 01/29/2006 20:00:00 5.3 0.7 7.6 3 5.3 0.7 7.2 3.4 4.2 0.7 6.5 2.6 305 9 311 165 -8.6 0 -8.5 -8.7 01/29/2006 20:10:00 5.8 0.6 7.2 4.2 5.8 0.6 7.6 3.8 4.5 0.6 6.1 3 301 6 297 165 -8.6 0 -8.5 -8.7 01/29/2006 20:20:00 5.4 0.8 7.2 3.8 5.3 0.8 7.2 3.8 4.1 0.6 6.1 2.6 304 7 292 165 -8.7 0 -8.5 -8.7 01/29/2006 20:30:00 4.8 0.6 6.1 2.6 4.7 0.6 6.1 2.6 4 0.7 5.7 2.3 311 10 287 165 -8.7 0 -8.5 -8.9 01/29/2006 20:40:00 4.9 0.8 7.6 3 4.8 0.9 7.6 2.6 4.5 0.9 8 2.6 321 17 340 165 -8.7 0 -8.5 -8.9 01/29/2006 20:50:00 5.4 1 8.4 3.4 5.2 1 8.4 3 5 0.8 7.6 3 321 11 328 165 -8.5 0 -8.5 -8.7 01/29/2006 21:00:00 6.6 1 9.1 4.2 6.5 1 9.1 4.2 6.1 1.1 8.4 3.4 316 10 317 165 -8.5 0 -8.5 -8.7 01/29/2006 21:10:00 6.2 0.8 9.1 4.2 6 0.8 9.1 4.2 5.2 0.9 7.6 3 308 8 305 165 -8.7 0 -8.3 -8.9 01/29/2006 21:20:00 6.5 0.8 8.4 4.6 6.4 0.8 8.4 4.6 5.7 0.8 7.2 3.4 311 7 298 165 -8.7 0 -8.5 -8.7 01/29/2006 21:30:00 6.7 1 10.3 4.2 6.7 1 10.3 3.8 6.2 1.1 8.8 3.4 315 13 306 165 -8.6 0.1 -8.5 -8.9 01/29/2006 21:40:00 5.7 1.2 8.8 2.6 5.6 1.2 8.8 2.6 5.1 1.2 7.6 2.6 313 10 295 165 -8.7 0 -8.5 -8.9 01/29/2006 21:50:00 5.4 0.8 7.2 3.4 5.3 0.8 7.2 3 4.7 0.9 7.6 2.6 312 9 308 165 -8.8 0.1 -8.5 -9.1 01/29/2006 22:00:00 4.9 0.7 6.8 3.4 4.9 0.6 6.5 3.4 4.3 0.8 6.5 2.3 311 8 305 165 -9 0 -8.9 -9.1 01/29/2006 22:10:00 5.4 1 8.4 2.6 5.3 1.1 8.4 3 5.3 1 8.4 3.4 330 13 337 165 -8.7 0.1 -8.5 -9.1 01/29/2006 22:20:00 5.1 0.8 7.6 3.4 4.9 0.9 7.6 2.6 4.7 0.8 6.8 2.3 328 14 339 165 -8.8 0 -8.5 -8.9 01/29/2006 22:30:00 5.2 1.2 9.5 3.4 5.1 1.2 9.1 3.4 5.1 1.2 9.5 3.4 326 10 319 165 -8.7 0 -8.5 -8.7 01/29/2006 22:40:00 5.9 1 8 3.4 5.8 1 8 3.4 5.3 1.1 8.4 3 314 13 326 165 -8.4 0.1 -8.1 -8.7 01/29/2006 22:50:00 5.3 1 7.2 3 5.2 1 7.6 3 4.8 0.9 7.2 3 312 11 317 165 -8.5 0 -8.3 -8.7 01/29/2006 23:00:00 5.5 0.8 7.2 3.4 5.4 0.8 7.2 3 4.5 0.8 6.5 2.3 304 11 305 165 -8.5 0.1 -8.1 -8.9 01/29/2006 23:10:00 6 0.9 9.1 4.2 5.9 0.9 9.1 3.8 4.8 1 8 3 303 9 292 165 -8.8 0 -8.7 -8.9 01/29/2006 23:20:00 5.7 0.7 8 3.8 5.6 0.7 8 3.4 4.9 0.8 8 2.6 308 7 309 165 -8.7 0 -8.5 -8.9 01/29/2006 23:30:00 6.2 1 8.8 3.4 6.2 1.1 9.1 3.8 6.2 1 9.1 4.2 334 12 347 165 -8.8 0.1 -8.5 -8.9 01/29/2006 23:40:00 5.7 0.8 7.6 3.8 5.6 0.8 7.6 3.8 5.7 0.9 8 3 322 9 328 165 -8.6 0 -8.5 -8.9 01/29/2006 23:50:00 5.4 0.8 7.2 3.4 5.3 0.8 7.2 3.4 4.2 0.8 6.8 2.3 298 7 298 165 -8.8 0 -8.5 -8.9 01/30/2006 00:00:00 6.8 0.9 8.4 4.2 6.7 0.9 8.4 4.2 5 0.8 6.8 3 299 5 298 165 -8.8 0 -8.7 -8.9 01/30/2006 00:10:00 7.7 0.6 8.8 6.1 7.6 0.6 8.8 5.7 5.5 0.6 7.6 3.8 301 4 300 165 -8.9 0 -8.7 -9.1 01/30/2006 00:20:00 7.7 0.5 9.5 6.5 7.6 0.5 9.5 6.1 5.2 0.5 6.8 3.8 302 3 305 165 -9.1 0 -8.9 -9.1 01/30/2006 00:30:00 7.6 0.4 8.4 5.7 7.5 0.5 8.4 5.7 5.1 0.5 6.8 3.8 303 3 305 165 -9.1 0 -8.9 -9.1 01/30/2006 00:40:00 7 0.8 9.1 4.9 6.9 0.7 8.8 4.9 5.1 0.9 8.8 3.4 302 6 296 165 -9.2 0 -9.1 -9.3 01/30/2006 00:50:00 6.5 0.6 8.8 4.9 6.4 0.6 9.1 4.9 4.5 0.6 6.8 3 297 5 297 165 -9.4 0 -9.1 -9.5 01/30/2006 01:00:00 6.4 0.4 7.2 5.3 6.3 0.4 7.2 5.3 4.5 0.5 6.5 3 296 3 292 165 -9.3 0 -9.1 -9.5 01/30/2006 01:10:00 6.3 0.3 7.2 4.9 6.3 0.3 6.8 4.9 4.2 0.4 5.3 3 301 2 300 165 -9.4 0 -9.3 -9.5 01/30/2006 01:20:00 7 0.4 7.6 5.7 6.9 0.4 7.6 5.7 4.7 0.5 6.1 3.4 302 3 299 165 -9.4 0 -9.3 -9.5 01/30/2006 01:30:00 6.8 0.3 8 5.7 6.7 0.3 8 5.7 4.7 0.5 6.1 3.4 303 2 305 165 -9.4 0 -9.3 -9.7 01/30/2006 01:40:00 6.5 0.6 7.6 4.9 6.4 0.6 7.6 4.9 4.8 0.5 6.1 3.4 305 4 302 165 -9.4 0 -9.3 -9.7 01/30/2006 01:50:00 6.6 0.6 8 4.6 6.5 0.6 7.6 4.6 4.8 0.6 6.5 3.4 305 4 301 165 -9.5 0 -9.3 -9.7 01/30/2006 02:00:00 7 0.6 8.4 5.7 7 0.6 8.4 5.7 4.8 0.6 7.2 3.4 302 4 300 165 -9.4 0 -9.1 -9.5 01/30/2006 02:10:00 6.8 0.9 9.1 4.6 6.7 0.9 8.8 4.9 5.2 1 7.6 3.4 301 7 301 165 -9.1 0 -9.1 -9.3 01/30/2006 02:20:00 6.4 0.6 8.4 4.9 6.4 0.6 8.4 4.9 4.7 0.7 7.2 3 300 4 296 165 -9.1 0 -8.9 -9.3 01/30/2006 02:30:00 7 0.6 8.4 5.3 6.9 0.6 8 5.3 5.1 0.5 6.5 3.4 304 4 302 165 -9.1 0 -9.1 -9.3 01/30/2006 02:40:00 6.9 0.5 7.6 5.3 6.8 0.5 7.6 5.3 4.7 0.4 6.1 3.8 300 3 298 165 -9.3 0 -8.9 -9.3 01/30/2006 02:50:00 5.9 0.4 6.8 4.6 5.9 0.4 6.8 4.6 4.5 0.5 6.1 3.4 295 3 300 165 -9.5 0 -9.3 -9.7 01/30/2006 03:00:00 5.2 0.4 6.5 4.2 5.2 0.4 6.5 4.2 4.3 0.6 5.7 3 294 4 298 165 -9.5 0 -9.3 -9.7 01/30/2006 03:10:00 5.4 0.3 6.1 4.6 5.4 0.3 6.5 4.6 4.1 0.5 5.3 2.6 294 3 299 165 -9.4 0 -9.3 -9.7 01/30/2006 03:20:00 5.1 0.2 5.7 4.6 5.1 0.2 5.7 4.6 4.1 0.4 4.9 3 292 2 290 165 -9.5 0 -9.3 -9.7 01/30/2006 03:30:00 4.8 0.3 5.3 4.2 4.8 0.3 5.3 4.2 3.5 0.5 4.6 2.6 297 4 293 165 -9.4 0 -9.3 -9.7 01/30/2006 03:40:00 4.5 0.4 5.3 3.4 4.5 0.4 5.3 3.4 3.3 0.6 4.9 1.9 305 4 309 165 -9.3 0 -9.1 -9.5 01/30/2006 03:50:00 4.5 0.4 5.3 3 4.5 0.4 5.3 3.4 3.5 0.5 4.6 2.3 307 4 304 165 -9.3 0.1 -9.1 -9.7 01/30/2006 04:00:00 4.6 0.5 6.1 3.4 4.7 0.5 6.1 3.4 3.3 0.4 4.6 1.9 299 5 301 165 -9 0 -8.9 -9.1 01/30/2006 04:10:00 4.6 0.3 5.3 3.8 4.6 0.3 5.3 3.8 3.3 0.5 4.6 2.3 299 4 298 165 -9 0 -8.9 -9.1 01/30/2006 04:20:00 4.9 0.3 5.7 4.2 5 0.3 5.7 4.2 3.4 0.4 4.6 2.6 300 3 305 165 -9.1 0 -8.9 -9.3 01/30/2006 04:30:00 5.6 0.5 6.8 4.2 5.6 0.5 6.5 4.2 4 0.6 5.3 2.6 304 3 305 165 -9.1 0 -8.9 -9.3 01/30/2006 04:40:00 5.6 0.4 6.8 4.2 5.6 0.4 6.5 3.8 3.8 0.5 4.9 2.6 302 4 302 165 -9 0 -8.9 -9.1 01/30/2006 04:50:00 5.1 0.5 6.1 3.8 5.1 0.5 6.5 3.8 3.5 0.5 4.9 2.3 299 5 298 165 -9.2 0 -8.9 -9.3 01/30/2006 05:00:00 5.4 0.4 6.1 4.2 5.4 0.3 6.1 4.6 3.8 0.5 4.9 2.6 304 3 303 165 -9.1 0 -8.9 -9.3 01/30/2006 05:10:00 5.4 0.6 6.5 4.2 5.4 0.6 6.5 3.8 4.6 0.7 6.1 2.6 309 4 307 165 -9.1 0 -8.9 -9.3 01/30/2006 05:20:00 3.8 0.7 4.9 1.9 3.9 0.6 5.3 1.9 3.3 0.6 4.9 1.9 306 6 304 165 -8.9 0 -8.7 -9.1 01/30/2006 05:30:00 2.4 0.8 3.8 0.4 2.5 0.7 4.2 1.1 2.3 0.6 3.4 0.7 312 10 308 165 -9 0 -8.9 -9.1 01/30/2006 05:40:00 2.3 0.6 3.8 1.1 2.5 0.5 4.2 1.5 2 0.5 3.8 1.1 303 8 308 165 -8.9 0 -8.7 -9.1 01/30/2006 05:50:00 4 0.5 5.3 2.6 4.2 0.6 5.7 2.6 3.3 0.6 4.9 1.9 298 7 295 165 -8.8 0 -8.5 -8.9 01/30/2006 06:00:00 4.1 0.6 5.7 3 4.3 0.5 6.1 3 3.3 0.6 5.3 1.9 302 5 296 165 -8.8 0 -8.7 -8.9 01/30/2006 06:10:00 3.5 0.4 4.6 2.3 3.7 0.4 4.9 2.3 3.3 0.5 4.9 2.3 298 9 289 165 -8.9 0 -8.7 -9.1 01/30/2006 06:20:00 4.5 0.3 4.9 3.8 4.6 0.3 5.3 3.8 3.7 0.4 4.6 2.6 307 4 302 165 -9 0 -8.7 -9.1 01/30/2006 06:30:00 3.8 0.4 4.9 3 3.9 0.4 4.9 3 3.1 0.6 4.6 1.9 307 7 317 165 -9.1 0 -9.1 -9.3 01/30/2006 06:40:00 3.9 0.5 4.9 2.6 4 0.5 5.3 2.6 3.9 0.5 4.9 2.6 320 7 330 165 -9 0.2 -8.5 -9.3 01/30/2006 06:50:00 3.3 0.3 3.8 2.3 3.5 0.4 4.6 2.6 3.3 0.3 3.8 2.3 334 9 328 165 -8.7 0.1 -8.5 -9.1 01/30/2006 07:00:00 3.4 0.3 3.8 2.6 3.5 0.6 4.2 1.5 3.4 0.3 4.2 2.6 347 3 346 165 -9.1 0 -8.9 -9.1 01/30/2006 07:10:00 2.8 0.4 3.4 1.9 2.1 0.5 3.8 1.1 2.9 0.3 3.8 1.9 355 4 349 165 -9.1 0 -8.9 -9.1 01/30/2006 07:20:00 2.7 0.3 3.8 1.9 2.2 0.6 4.2 1.1 2.9 0.3 3.8 2.3 353 3 350 165 -8.8 0 -8.5 -9.1 01/30/2006 07:30:00 3.5 0.2 3.8 3 3.1 0.5 4.2 1.9 3.7 0.2 4.2 3 350 2 348 165 -9.1 0 -8.9 -9.1 01/30/2006 07:40:00 3.1 0.3 3.8 2.6 1.9 0.4 3.4 1.1 3.2 0.3 4.2 2.6 356 3 353 165 -9.1 0 -9.1 -9.3 01/30/2006 07:50:00 3 0.2 3.4 2.6 2.2 0.5 3.4 1.1 3.2 0.2 3.8 3 353 3 357 165 -9 0 -8.9 -9.3 01/30/2006 08:00:00 3.2 0.3 3.8 2.3 2.4 0.6 4.2 1.1 3.2 0.4 4.2 2.3 353 4 351 165 -8.8 0 -8.5 -8.9 01/30/2006 08:10:00 2.9 0.3 3.8 1.9 2.8 0.6 3.8 0.7 3 0.3 3.8 2.3 346 6 343 165 -8.5 0 -8.3 -8.7 01/30/2006 08:20:00 2.8 0.4 3.8 1.9 2.4 0.5 3.8 1.1 3 0.3 3.8 2.3 350 5 354 165 -8.2 0 -8.1 -8.5 01/30/2006 08:30:00 3.2 0.4 4.6 2.6 2.1 0.6 3.8 1.1 3.3 0.3 4.2 2.6 357 5 353 165 -8 0 -7.9 -8.1 01/30/2006 08:40:00 3.6 0.3 4.6 2.6 2.2 0.5 3.8 1.1 3.8 0.3 4.6 3 358 4 0 165 -8 0 -8.1 -8.1 01/30/2006 08:50:00 3.8 0.3 4.6 3 2.3 0.7 4.9 1.1 3.9 0.3 4.9 3 359 6 355 165 -8 0 -7.6 -8.1 01/30/2006 09:00:00 3.5 0.3 4.2 3 2.1 0.4 3.8 1.1 3.8 0.2 4.6 3.4 0 5 2 165 -7.9 0 -7.6 -8.1 01/30/2006 09:10:00 3.4 0.4 4.6 2.3 2.2 0.7 4.6 1.1 3.5 0.4 4.6 2.6 0 7 349 165 -7.9 0 -7.6 -8.1 01/30/2006 09:20:00 3 0.4 4.2 1.9 2.4 0.7 3.8 1.1 3.1 0.4 4.2 1.9 353 8 354 165 -7.7 0 -7.6 -8.1 01/30/2006 09:30:00 1.5 1 3.8 0.4 1.6 1 3.8 0.4 1.8 1.1 4.2 0.4 315 56 349 165 -7.5 0.1 -7.2 -7.6 01/30/2006 09:40:00 3.3 0.8 4.9 1.1 3.4 0.7 4.6 1.5 3.5 0.7 5.3 1.5 238 13 251 165 -7.9 0.2 -7.4 -8.3 01/30/2006 09:50:00 3.8 0.8 5.3 1.5 4 0.8 5.7 1.9 4.2 0.9 5.7 1.9 236 12 249 165 -8.2 0.1 -8.1 -8.3 01/30/2006 10:00:00 3.3 0.4 4.2 2.3 3.5 0.4 4.6 2.3 3.5 0.4 4.6 2.3 227 4 226 165 -8.1 0 -8.1 -8.3 01/30/2006 10:10:00 3.4 0.3 3.8 2.6 3.6 0.2 4.2 3 3.6 0.3 4.2 3 219 4 221 165 -8.1 0 -8.1 -8.3 01/30/2006 10:20:00 2.8 0.4 3.8 1.9 3.1 0.4 4.2 1.9 3 0.3 3.8 2.3 221 8 242 165 -8 0 -7.9 -8.1 01/30/2006 10:30:00 1.7 0.8 3 0.4 2.1 0.7 3.4 0.7 2.1 0.7 3.4 0.7 222 5 211 165 -8 0 -7.6 -8.1 01/30/2006 10:40:00 0.6 0.4 1.9 0.4 0.8 0.5 1.9 0.4 1 0.6 2.3 0.4 282 51 323 165 -7.9 0 -7.6 -8.1 01/30/2006 10:50:00 0.4 0.2 1.5 0.4 0.5 0.3 1.5 0.4 0.6 0.4 1.5 0.4 335 10 312 165 -8 0 -7.9 -8.1 01/30/2006 11:00:00 0.6 0.3 1.9 0.4 0.7 0.4 2.3 0.4 0.8 0.4 1.9 0.4 22 22 53 165 -7.8 0 -7.6 -8.1 01/30/2006 11:10:00 1.2 0.6 2.3 0.4 1.3 0.6 2.6 0.4 1.3 0.5 2.3 0.4 41 13 51 165 -7.6 0 -7.4 -7.6 01/30/2006 11:20:00 1.1 0.6 2.3 0.4 1.2 0.6 2.3 0.4 1.4 0.5 2.3 0.4 49 2 47 165 -7.5 0 -7.4 -7.6 01/30/2006 11:30:00 0.4 0.2 1.1 0.4 0.4 0.2 1.5 0.4 0.6 0.3 1.5 0.4 96 17 68 165 -7.5 0 -7.2 -7.6 01/30/2006 11:40:00 0.4 0.1 1.1 0.4 0.4 0.2 1.5 0.4 0.5 0.3 2.3 0.4 131 82 344 165 -7.3 0 -7.2 -7.4 01/30/2006 11:50:00 0.4 0.1 1.1 0.4 0.4 0.1 1.1 0.4 0.6 0.3 1.5 0.4 347 12 357 165 -7.2 0 -7 -7.4 01/30/2006 12:00:00 1 0.4 1.9 0.4 0.9 0.4 1.9 0.4 1.3 0.4 2.3 0.4 330 7 336 165 -7.5 0.1 -7.2 -7.6 01/30/2006 12:10:00 1.3 0.6 3 0.4 1 0.6 3 0.4 1.4 0.7 2.6 0.4 17 20 28 165 -7.5 0 -7.2 -7.6 01/30/2006 12:20:00 1.5 0.6 2.6 0.4 1.5 0.6 2.6 0.4 1.6 0.6 3 0.4 40 9 46 165 -7.5 0 -7.2 -7.6 01/30/2006 12:30:00 1.3 0.5 2.6 0.4 1.4 0.6 2.6 0.4 1.5 0.5 2.6 0.4 37 11 33 165 -7.4 0 -7.2 -7.6 01/30/2006 12:40:00 1.4 0.4 2.6 0.4 1.4 0.5 2.6 0.4 1.6 0.5 2.6 0.4 26 16 37 165 -7.3 0 -7 -7.4 01/30/2006 12:50:00 1.6 0.5 3.4 0.4 1.5 0.5 2.6 0.4 1.9 0.5 3.4 0.7 24 15 0 165 -7.1 0 -6.8 -7.2 01/30/2006 13:00:00 2.4 0.4 3.4 1.5 1.9 0.6 3 0.7 2.4 0.4 3.4 0.7 11 8 15 165 -6.9 0 -6.8 -7.2 01/30/2006 13:10:00 2.5 0.3 3 1.9 2.1 0.5 3 0.7 2.7 0.3 3.4 1.9 351 7 351 165 -6.9 0 -6.8 -7.2 01/30/2006 13:20:00 2.3 0.4 3.4 1.5 1.8 0.6 3.8 0.4 2.5 0.3 3.4 1.9 353 6 338 165 -7.1 0 -6.8 -7.2 01/30/2006 13:30:00 2.1 0.3 2.6 1.5 1.3 0.4 2.6 0.7 2.4 0.2 3 1.9 2 4 4 165 -6.9 0 -6.6 -7 01/30/2006 13:40:00 2.6 0.3 3.4 1.9 1.7 0.6 3 0.7 2.8 0.3 3.4 1.9 357 6 353 165 -6.6 0 -6.4 -6.8 01/30/2006 13:50:00 1.8 0.5 3 0.7 1.6 0.5 3 0.7 2.2 0.4 3 1.5 347 9 355 165 -6.7 0.1 -6.6 -6.8 01/30/2006 14:00:00 1.5 0.3 2.3 0.7 1.5 0.4 2.3 0.4 1.9 0.2 2.6 1.5 348 2 344 165 -6.7 0 -6.4 -6.8 01/30/2006 14:10:00 2.3 0.5 3.4 1.1 2.3 0.6 3.4 0.7 2.5 0.5 3.4 1.1 341 5 340 165 -6.2 0.1 -6.1 -6.6 01/30/2006 14:20:00 3.1 0.3 3.8 2.3 3 0.4 4.2 1.9 3 0.3 3.8 2.3 342 7 348 165 -6.5 0 -6.1 -6.8 01/30/2006 14:30:00 2.8 0.3 3.4 2.3 2.2 0.5 3.4 1.1 2.9 0.3 3.4 1.9 351 5 344 165 -6.6 0 -6.4 -6.8 01/30/2006 14:40:00 2.8 0.2 3.4 2.3 2.1 0.6 3.4 0.7 2.9 0.3 3.4 1.9 354 5 359 165 -6.2 0 -5.9 -6.6 01/30/2006 14:50:00 2.2 0.7 3.4 0.4 1.9 0.7 3.4 0.4 2.5 0.6 3.4 1.1 351 4 350 165 -6.4 0.3 -5.9 -6.8 01/30/2006 15:00:00 1.3 0.3 2.3 0.4 1.1 0.4 2.6 0.4 1.6 0.3 2.3 0.7 2 13 4 165 -6.9 0 -6.6 -7 01/30/2006 15:10:00 0.9 0.5 1.9 0.4 1.1 0.5 1.9 0.4 1 0.3 1.9 0.4 53 23 36 165 -6.5 0 -6.4 -6.8 01/30/2006 15:20:00 0.6 0.3 1.5 0.4 0.8 0.4 1.9 0.4 0.7 0.4 1.5 0.4 94 14 83 165 -6.5 0 -6.4 -6.6 01/30/2006 15:30:00 0.6 0.3 1.5 0.4 0.7 0.5 2.3 0.4 1 0.4 1.9 0.4 99 79 113 165 -6 0.3 -5.3 -6.4 01/30/2006 15:40:00 0.5 0.3 1.5 0.4 0.7 0.3 1.5 0.4 1.2 0.3 1.9 0.4 351 16 339 165 -5.3 0.1 -5 -5.5 01/30/2006 15:50:00 0.7 0.4 1.5 0.4 0.8 0.5 1.9 0.4 1.1 0.5 1.9 0.4 47 20 31 165 -5.1 0 -4.8 -5.5 01/30/2006 16:00:00 0.4 0.1 0.7 0.4 0.5 0.2 1.1 0.4 0.8 0.4 1.5 0.4 43 0 43 165 -6 0.2 -5.3 -6.4 01/30/2006 16:10:00 0.4 0.1 1.5 0.4 0.5 0.2 1.5 0.4 0.7 0.4 1.5 0.4 49 15 57 165 -6.4 0 -6.1 -6.6 01/30/2006 16:20:00 0.6 0.3 1.5 0.4 0.7 0.4 1.5 0.4 1 0.5 1.9 0.4 22 4 20 165 -6.5 0 -6.4 -6.6 01/30/2006 16:30:00 0.5 0.3 1.5 0.4 0.6 0.3 1.5 0.4 1 0.4 1.9 0.4 9 8 18 165 -6.6 0 -6.4 -6.8 01/30/2006 16:40:00 0.4 0.2 1.1 0.4 0.7 0.3 1.5 0.4 0.9 0.3 1.5 0.4 13 9 22 165 -6.9 0 -6.6 -7.2 01/30/2006 16:50:00 0.7 0.4 1.9 0.4 0.9 0.4 1.9 0.4 0.9 0.4 1.9 0.4 34 15 34 165 -7.1 0 -6.8 -7.2 01/30/2006 17:00:00 1.4 0.4 2.3 0.4 1 0.4 2.3 0.4 1.5 0.3 2.3 0.7 356 6 347 165 -7.2 0 -7 -7.4 01/30/2006 17:10:00 0.7 0.4 1.5 0.4 0.7 0.3 1.5 0.4 1.1 0.3 1.5 0.4 355 3 356 165 -7.4 0 -7.2 -7.4 01/30/2006 17:20:00 0.9 0.3 1.5 0.4 1 0.4 1.5 0.4 1.2 0.4 1.9 0.4 324 2 328 165 -7.5 0 -7.2 -7.6 01/30/2006 17:30:00 0.4 0 0.7 0.4 0.4 0 0.4 0.4 0.4 0.1 0.7 0.4 323 1 323 165 -7.4 0 -7.2 -7.6 01/30/2006 17:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0.1 1.1 0.4 320 0 165 165 -7.3 0 -7.2 -7.4 01/30/2006 17:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 320 0 165 165 -7.5 0 -7.2 -7.6 01/30/2006 18:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 320 0 165 165 -8 0.1 -7.6 -8.3 01/30/2006 18:10:00 0.6 0.3 1.5 0.4 0.7 0.3 1.5 0.4 0.7 0.4 1.5 0.4 196 45 166 165 -8.1 0 -8.1 -8.3 01/30/2006 18:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0.1 1.1 0.4 166 0 165 165 -8.1 0 -7.9 -8.3 01/30/2006 18:30:00 0.6 0.3 1.1 0.4 0.7 0.4 1.5 0.4 0.7 0.4 1.5 0.4 162 4 158 165 -8.3 0 -8.1 -8.5 01/30/2006 18:40:00 0.6 0.3 1.1 0.4 0.7 0.4 1.5 0.4 0.7 0.4 1.5 0.4 156 0 157 165 -8.1 0 -8.1 -8.3 01/30/2006 18:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 156 0 165 165 -8.3 0.1 -8.1 -8.5 01/30/2006 19:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 156 0 165 165 -8.5 0.1 -8.1 -8.7 01/30/2006 19:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0.1 1.1 0.4 156 0 165 165 -8.3 0 -8.1 -8.7 01/30/2006 19:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0.1 0.7 0.4 141 22 165 165 -8.2 0 -8.1 -8.5 01/30/2006 19:30:00 0.4 0.1 1.1 0.4 0.4 0.1 1.1 0.4 0.4 0.2 1.1 0.4 139 29 161 165 -8.4 0.1 -8.1 -8.7 01/30/2006 19:40:00 1.5 0.7 3 0.4 1.3 0.6 2.3 0.4 1.8 0.6 3 0.4 357 7 351 165 -8.6 0 -8.5 -8.7 01/30/2006 19:50:00 2.1 0.5 3 1.1 1.5 0.4 2.3 0.4 2.2 0.5 3 1.5 356 2 351 165 -8.5 0 -8.3 -8.9 01/30/2006 20:00:00 1.1 0.6 2.3 0.4 0.9 0.5 1.9 0.4 1.6 0.4 2.6 0.7 0 5 355 165 -8.3 0.1 -8.1 -8.5 01/30/2006 20:10:00 0.4 0.2 1.1 0.4 0.4 0.2 1.1 0.4 1.1 0.2 1.5 0.7 5 4 3 165 -7.9 0 -7.6 -8.1 01/30/2006 20:20:00 0.4 0 0.4 0.4 0.4 0 0.7 0.4 0.9 0.2 1.5 0.4 14 0 165 165 -7.7 0 -7.4 -8.1 01/30/2006 20:30:00 0.4 0.1 0.7 0.4 0.4 0.1 0.7 0.4 0.7 0.3 1.1 0.4 14 0 14 165 -8 0.1 -7.6 -8.1 01/30/2006 20:40:00 0.6 0.3 1.5 0.4 0.6 0.3 1.1 0.4 0.8 0.3 1.5 0.4 33 12 34 165 -8.3 0 -8.1 -8.5 01/30/2006 20:50:00 0.4 0.1 1.1 0.4 0.4 0.1 1.1 0.4 0.5 0.3 1.1 0.4 32 0 32 165 -8.2 0.1 -8.1 -8.5 01/30/2006 21:00:00 1.5 0.5 2.3 0.4 0.8 0.4 1.9 0.4 1.7 0.4 2.3 0.7 10 11 359 165 -8 0 -7.9 -8.1 01/30/2006 21:10:00 2.4 0.3 3 1.5 1.3 0.3 2.3 0.7 2.4 0.2 3 1.9 357 3 0 165 -8.1 0 -8.1 -8.3 01/30/2006 21:20:00 1.7 0.2 2.3 1.1 0.9 0.3 1.5 0.4 1.7 0.2 2.3 1.5 2 2 3 165 -7.9 0 -7.6 -8.1 01/30/2006 21:30:00 1.9 0.2 2.3 1.5 0.9 0.2 1.5 0.4 1.8 0.3 2.3 1.1 3 0 3 165 -7.5 0 -7.4 -7.6 01/30/2006 21:40:00 2.4 0.2 2.6 1.9 1.3 0.3 2.3 0.7 2.4 0.2 2.6 1.9 358 4 356 165 -7.5 0 -7.2 -7.6 01/30/2006 21:50:00 2.4 0.2 3 1.9 1.4 0.3 2.3 0.7 2.4 0.2 3 1.9 7 2 9 165 -7.4 0 -7.2 -7.6 01/30/2006 22:00:00 2.8 0.3 3.4 2.3 2.3 0.4 3 1.1 2.7 0.2 3 2.3 17 6 19 165 -7.1 0 -6.8 -7.4 01/30/2006 22:10:00 3.1 0.4 3.8 2.3 2.7 0.4 3.8 1.9 3 0.4 4.2 2.3 21 4 20 165 -6.9 0 -6.8 -7 01/30/2006 22:20:00 3.8 0.3 4.6 3 2.8 0.6 3.8 1.5 3.7 0.3 4.6 3 11 3 6 165 -6.9 0 -6.8 -6.8 01/30/2006 22:30:00 3.8 0.3 4.9 3 2.7 0.7 4.2 1.1 3.7 0.3 4.9 3 10 4 10 165 -6.9 0 -6.8 -6.8 01/30/2006 22:40:00 3.8 0.4 4.9 3 2.6 0.7 4.2 1.1 3.7 0.5 4.9 3 8 4 10 165 -6.7 0 -6.6 -6.8 01/30/2006 22:50:00 3.7 0.4 4.9 2.6 2.5 0.7 4.2 1.1 3.6 0.3 4.6 3 5 7 16 165 -6.6 0 -6.6 -6.8 01/30/2006 23:00:00 4 0.4 5.3 3 3.5 0.8 4.9 1.9 4 0.4 4.9 3 350 5 357 165 -6.7 0 -6.6 -6.8 01/30/2006 23:10:00 3.9 0.5 5.3 3 2.3 0.6 4.2 1.1 3.8 0.4 4.9 3 0 5 5 165 -6.5 0.1 -6.4 -6.8 01/30/2006 23:20:00 4.8 0.4 6.1 4.2 3.9 1 6.1 1.9 4.8 0.4 6.1 3.8 352 5 0 165 -6.3 0 -6.1 -6.6 01/30/2006 23:30:00 4.9 0.4 5.7 3.8 3.7 0.8 5.3 1.5 4.8 0.3 5.7 4.2 354 6 351 165 -6.3 0 -6.1 -6.4 01/30/2006 23:40:00 5.5 0.5 6.8 4.2 4 1 6.8 2.3 5.5 0.4 6.8 4.6 355 5 352 165 -6.4 0 -6.1 -6.6 01/30/2006 23:50:00 5.4 0.5 6.5 4.2 3.8 0.9 6.5 1.9 5.4 0.4 6.5 4.6 355 5 357 165 -6.4 0 -6.1 -6.6 01/31/2006 00:00:00 5.7 0.4 6.8 4.6 4.2 1 6.5 2.3 5.5 0.4 6.5 4.6 354 5 355 165 -6.4 0 -6.4 -6.6 01/31/2006 00:10:00 5.9 0.4 6.8 4.9 5.1 1 6.8 2.6 5.8 0.5 6.8 4.6 351 5 355 165 -6.4 0 -6.1 -6.6 01/31/2006 00:20:00 5.8 0.6 7.6 4.6 5.7 0.8 8 2.6 5.6 0.5 7.2 4.6 346 5 342 165 -6.4 0 -6.1 -6.6 01/31/2006 00:30:00 6.7 0.8 8.8 4.9 6.5 1 9.5 4.6 6.5 0.7 8.8 4.9 346 6 340 165 -6.4 0 -6.1 -6.4 01/31/2006 00:40:00 6.9 0.6 8.4 5.3 6.7 1 9.1 3.8 6.8 0.6 8.4 5.3 346 6 358 165 -6.2 0 -6.1 -6.4 01/31/2006 00:50:00 7.1 0.8 9.5 5.7 6.3 1.1 9.1 3.4 7 0.7 9.1 5.7 348 7 356 165 -6.3 0 -6.1 -6.4 01/31/2006 01:00:00 7.2 0.7 9.1 5.3 6.7 1 9.1 3.8 7.1 0.7 8.8 5.3 348 6 353 165 -6.2 0 -6.1 -6.4 01/31/2006 01:10:00 7.1 0.6 8.8 5.3 6 1.1 8.8 3 7 0.6 8.8 5.7 352 6 356 165 -6.1 0 -5.9 -6.4 01/31/2006 01:20:00 6.7 0.6 8.4 4.9 6.3 1 8 3.4 6.7 0.6 8.4 5.3 347 7 347 165 -6 0 -5.7 -6.1 01/31/2006 01:30:00 7.2 0.7 8.8 5.7 6.9 1 9.1 3.8 7 0.7 8.4 4.9 346 7 344 165 -5.9 0 -5.7 -6.1 01/31/2006 01:40:00 7 0.6 8.4 5.7 6.7 0.9 8.8 3.8 6.8 0.5 8.4 5.3 344 8 334 165 -5.9 0 -5.7 -5.9 01/31/2006 01:50:00 7.2 0.6 9.1 5.7 6.7 1 9.9 3.8 7.2 0.7 8.8 5.3 348 6 344 165 -5.9 0 -5.7 -5.9 01/31/2006 02:00:00 8.3 0.7 9.9 6.8 7.5 1.1 9.9 3.8 8.3 0.7 10.3 6.8 349 5 353 165 -5.9 0 -5.7 -5.9 01/31/2006 02:10:00 8.4 0.9 10.7 5.7 8 1.3 11.5 4.2 8.2 1.1 11.5 6.1 345 7 347 165 -5.8 0 -5.7 -5.9 01/31/2006 02:20:00 8.8 0.9 11.5 6.8 8.6 1.1 11.5 4.9 8.3 1 11.1 5.7 340 9 341 165 -5.8 0 -5.7 -5.9 01/31/2006 02:30:00 8.1 0.9 11.1 6.1 8.2 0.9 11.1 5.7 8.3 0.9 11.1 6.1 336 8 319 165 -5.6 0 -5.5 -5.7 01/31/2006 02:40:00 7.1 0.8 9.9 4.6 6.9 1 9.9 4.2 7.1 0.9 10.3 4.9 339 10 342 165 -5.8 0 -5.5 -5.9 01/31/2006 02:50:00 6.9 0.7 9.1 5.3 6.7 1.1 8.8 3 7 0.7 8.8 5.7 341 9 332 165 -5.9 0 -5.7 -5.9 01/31/2006 03:00:00 7.9 0.9 9.9 4.9 7.8 1.2 10.3 4.6 8 0.9 9.9 5.3 343 8 348 165 -5.8 0 -5.5 -5.9 01/31/2006 03:10:00 8.5 0.9 10.7 6.5 8.5 1 10.7 6.5 8.5 0.8 10.3 6.8 342 7 338 165 -5.6 0 -5.5 -5.7 01/31/2006 03:20:00 7.9 0.9 11.1 6.1 7.5 1.3 11.1 3.8 8 0.9 10.7 5.7 345 9 339 165 -5.6 0 -5.5 -5.7 01/31/2006 03:30:00 8.1 1 10.7 6.1 8.1 1.1 11.1 5.7 8.1 1 10.3 4.9 338 9 332 165 -5.6 0 -5.5 -5.7 01/31/2006 03:40:00 8.5 1 11.5 6.1 8.5 1.1 11.5 4.9 8.6 1 11.8 6.1 337 10 332 165 -5.6 0 -5.5 -5.7 01/31/2006 03:50:00 8.7 1 10.7 6.1 8.4 1.1 11.1 5.7 8.8 1 11.1 5.3 344 8 342 165 -5.4 0 -5.3 -5.5 01/31/2006 04:00:00 8.8 1.3 11.8 6.5 8.8 1.5 12.6 5.7 8.8 1.5 13 6.1 338 10 343 165 -5.4 0 -5.3 -5.7 01/31/2006 04:10:00 8.5 1.1 11.1 6.1 8.5 1.2 11.8 5.3 8.6 1.1 11.5 6.1 338 9 352 165 -5.3 0.1 -5 -5.5 01/31/2006 04:20:00 9.1 1.1 11.8 6.5 9 1.2 11.8 5.7 8.7 1.3 11.8 4.6 329 15 330 165 -4.9 0 -4.6 -5.3 01/31/2006 04:30:00 8.9 1.2 12.2 6.5 8.2 1.5 12.6 4.2 8.9 1.2 13 6.1 344 11 340 165 -4.7 0 -4.6 -4.8 01/31/2006 04:40:00 9.3 1.5 14.5 5.7 8.6 2 14.5 4.6 9.1 1.4 13.3 5.7 345 9 334 165 -4.8 0 -4.6 -4.8 01/31/2006 04:50:00 10.4 1.2 14.1 7.6 10.3 1.4 13.7 6.1 10.1 1.2 13.7 7.6 336 9 331 165 -4.7 0 -4.6 -4.8 01/31/2006 05:00:00 9.1 1.2 13.3 6.5 9 1.5 13.3 4.2 9.1 1.3 12.6 6.5 341 9 342 165 -4.8 0 -4.6 -5 01/31/2006 05:10:00 8.6 1.2 11.5 5.7 8.4 1.4 11.5 4.9 8.5 1 11.8 5.7 341 9 325 165 -4.8 0 -4.6 -4.8 01/31/2006 05:20:00 9.1 1.7 13 4.9 9.1 1.7 12.6 4.6 9 1.7 13 5.3 339 9 338 165 -4.7 0 -4.6 -4.8 01/31/2006 05:30:00 10.4 1.3 13.7 6.8 10.4 1.3 13.7 6.5 10.4 1.3 13.7 6.8 334 8 338 165 -4.5 0 -4.4 -4.6 01/31/2006 05:40:00 10.2 1.2 13.3 7.6 10.2 1.3 13.3 6.5 10.1 1.3 13.3 7.6 336 10 329 165 -4.6 0 -4.4 -4.6 01/31/2006 05:50:00 9.8 1.2 12.6 6.5 9.5 1.5 12.6 5.3 9.5 1.2 12.2 6.1 341 10 333 165 -4.4 0 -4.2 -4.6 01/31/2006 06:00:00 9.3 1.1 12.2 6.5 8.8 1.6 11.8 4.2 9.2 1.1 12.2 6.1 339 12 10 165 -4.2 0 -3.9 -4.4 01/31/2006 06:10:00 9.3 1.2 12.2 6.5 9.2 1.4 12.6 5.3 9.3 1.1 12.2 6.8 338 10 329 165 -4.2 0 -3.9 -4.4 01/31/2006 06:20:00 8.9 1.1 11.8 6.1 8.7 1.2 12.6 4.9 8.7 1.1 12.2 5.7 338 10 341 165 -4.2 0 -3.9 -4.4 01/31/2006 06:30:00 9 1.3 12.6 5.7 8.7 1.3 13 5.3 8.9 1.2 12.6 6.5 341 9 348 165 -3.9 0 -3.7 -4.2 01/31/2006 06:40:00 9.2 1.3 12.6 5.7 9.1 1.5 12.6 4.9 9.2 1.4 13 5.7 335 10 337 165 -4 0.1 -3.9 -4.2 01/31/2006 06:50:00 9.5 1.4 13.7 6.1 9.5 1.5 13.7 6.1 9.3 1.5 14.1 5.3 329 11 338 165 -4.2 0 -3.9 -4.2 01/31/2006 07:00:00 9.9 1.1 12.6 6.8 9.8 1.1 13 6.5 9.9 1 12.6 6.8 334 9 331 165 -4.1 0 -3.9 -4.2 01/31/2006 07:10:00 9.5 1.2 13.7 6.5 9.4 1.2 13.3 6.5 9.1 1.2 12.6 6.1 328 10 321 165 -4 0 -3.9 -4.2 01/31/2006 07:20:00 9.4 1 11.8 6.5 9.2 1.1 11.8 6.5 9.2 1 12.2 6.1 331 11 333 165 -4 0 -3.9 -4.4 01/31/2006 07:30:00 9.8 1 12.2 7.2 9.8 1 12.6 7.6 9.6 1.1 13 6.8 331 9 339 165 -3.9 0 -3.7 -4.2 01/31/2006 07:40:00 9.1 1.3 12.6 5.7 9 1.4 12.6 4.9 8.8 1.4 13 5.3 327 11 332 165 -4.1 0.1 -3.9 -4.4 01/31/2006 07:50:00 9 1.5 13.7 5.7 9 1.6 14.1 5.3 8.5 2.1 13.7 4.6 318 15 343 165 -3.9 0.2 -3.5 -4.6 01/31/2006 08:00:00 8.7 1.2 12.6 6.1 8.6 1.2 13 6.1 7.7 1.5 12.2 4.9 313 12 330 165 -4.6 0.1 -4.4 -5 01/31/2006 08:10:00 8.8 1.4 12.2 4.2 8.8 1.4 12.2 4.2 8.6 1.5 12.6 4.9 322 13 325 165 -4.4 0.1 -4.2 -4.6 01/31/2006 08:20:00 9.3 1.8 14.1 5.3 9.1 1.9 14.5 4.9 8.8 1.9 14.5 4.9 323 15 325 165 -3.9 0 -3.5 -4.2 01/31/2006 08:30:00 9.4 1.4 13.7 5.7 9.3 1.3 13.3 5.7 8.9 1.5 13 5.3 322 11 328 165 -3.9 0.3 -3.5 -4.4 01/31/2006 08:40:00 9 1.7 12.6 4.9 8.9 1.7 12.6 4.9 8.5 1.7 12.6 3.8 329 12 325 165 -3.7 0 -3.5 -3.9 01/31/2006 08:50:00 10.8 1.5 13.7 6.8 10.7 1.5 13.3 6.5 10.5 1.7 13.7 6.1 331 10 340 165 -3.5 0 -3.3 -3.5 01/31/2006 09:00:00 10 1.4 14.5 6.1 9.9 1.5 14.9 5.3 9.6 1.3 14.1 5.3 332 8 339 165 -3.7 0 -3.5 -3.9 01/31/2006 09:10:00 11.7 1.5 15.6 7.2 11.6 1.7 15.6 6.5 11.4 1.6 15.3 7.6 331 10 337 165 -3.7 0 -3.5 -3.9 01/31/2006 09:20:00 11.5 1.4 15.6 8.4 11.3 1.6 14.9 6.1 11.1 1.5 15.3 7.6 334 13 342 165 -3.8 0 -3.5 -3.9 01/31/2006 09:30:00 11.1 1.8 16.4 7.2 11 1.8 15.6 6.8 10.9 1.8 16.8 7.6 334 10 351 165 -3.8 0 -3.5 -3.9 01/31/2006 09:40:00 10.8 1.8 16.4 6.8 10.7 2.1 16.8 6.5 10.8 1.9 16.8 6.8 339 10 338 165 -3.8 0 -3.5 -3.9 01/31/2006 09:50:00 10.7 1.6 16.1 7.6 10.6 1.7 16.8 6.1 10.8 1.7 16.4 7.2 336 11 353 165 -3.8 0 -3.7 -3.9 01/31/2006 10:00:00 10.2 1.6 14.9 6.1 10 1.7 14.5 4.9 10 1.7 15.6 3.8 338 12 330 165 -3.9 0 -3.7 -3.9 01/31/2006 10:10:00 10.9 1.6 15.3 7.2 10.5 1.8 16.1 6.5 10.9 1.7 14.9 5.7 337 11 339 165 -3.9 0 -3.7 -3.9 01/31/2006 10:20:00 9.7 1.7 14.1 4.9 9.7 1.8 14.5 4.9 9.7 1.9 14.5 4.6 335 10 335 165 -3.8 0 -3.5 -3.9 01/31/2006 10:30:00 9.3 1.7 14.9 4.9 9.1 1.9 14.5 3.4 9.1 1.9 14.5 4.9 337 13 343 165 -3.7 0 -3.5 -3.9 01/31/2006 10:40:00 9.1 1.4 13.7 5.7 8.9 1.5 14.5 4.2 8.9 1.3 13.7 5.3 337 10 344 165 -3.6 0 -3.5 -3.7 01/31/2006 10:50:00 9.5 1.5 13.3 6.5 9.4 1.5 14.5 6.5 9.6 1.5 13.7 6.1 337 9 338 165 -3.5 0 -3.3 -3.5 01/31/2006 11:00:00 9.5 1.5 13.7 6.5 9.4 1.6 13.3 5.7 9.6 1.3 13 6.5 338 10 328 165 -3.5 0 -3.3 -3.5 01/31/2006 11:10:00 9.2 1.3 13 6.5 8.8 1.4 13 6.1 9.2 1.5 13 5.7 340 12 349 165 -3.2 0 -3 -3.5 01/31/2006 11:20:00 8.5 1.2 11.8 5.7 8.3 1.3 12.2 4.6 8.3 1.2 11.1 5.7 335 11 334 165 -3.1 0 -2.8 -3.3 01/31/2006 11:30:00 9.1 1.5 13.3 5.7 8.8 1.7 13.7 3.8 9.2 1.5 13.7 6.1 338 11 349 165 -3 0 -2.8 -3.3 01/31/2006 11:40:00 9.2 1.3 13 6.1 8.5 1.7 13 4.2 9.2 1.4 13.7 5.7 343 12 358 165 -3.2 0 -3 -3.3 01/31/2006 11:50:00 9.5 1.7 13.3 5.7 9.2 2 13.3 4.6 9.4 1.7 13.3 5.7 341 9 335 165 -3.2 0 -3 -3.3 01/31/2006 12:00:00 9.5 2.1 14.9 5.3 9.4 2.2 15.3 5.3 9.6 2.2 14.9 4.9 333 11 344 165 -3 0.1 -2.8 -3.3 01/31/2006 12:10:00 8.9 2 14.1 4.6 8.8 2.1 14.5 4.2 8.7 2.1 12.6 3.8 332 14 339 165 -3 0 -2.8 -3 01/31/2006 12:20:00 9.7 1.5 13.7 6.1 9.6 1.6 13.7 4.2 9.7 1.3 13.7 6.5 337 9 334 165 -3.1 0 -3 -3.3 01/31/2006 12:30:00 8.9 1.5 13 5.3 8.9 1.7 13 5.3 9.1 1.5 13 6.1 336 10 330 165 -3.1 0 -2.8 -3.3 01/31/2006 12:40:00 8.6 1.8 13.3 4.9 8.6 1.8 13.7 4.9 8.3 1.9 13.3 3.8 329 15 340 165 -3 0 -2.8 -3.3 01/31/2006 12:50:00 9.6 2 15.6 5.3 9.5 2.1 15.6 5.3 9.5 1.9 14.5 4.9 336 11 342 165 -3.3 0.1 -3 -3.5 01/31/2006 13:00:00 10.6 2.1 15.3 6.5 10.7 2.2 15.3 6.8 10.5 2 15.3 6.5 333 9 339 165 -3.3 0 -3 -3.5 01/31/2006 13:10:00 11.6 1.6 16.1 6.1 11.6 1.7 15.6 5.7 11.4 1.8 16.4 7.2 334 8 327 165 -3.4 0 -3.3 -3.5 01/31/2006 13:20:00 12.2 2 16.1 7.2 12.2 2 16.1 7.2 11.8 1.9 16.4 6.8 335 8 334 165 -3.6 0 -3.3 -3.7 01/31/2006 13:30:00 12.1 1.9 17.2 7.6 12.2 2 17.2 7.2 11.9 1.7 16.1 6.8 336 8 333 165 -3.6 0 -3.5 -3.9 01/31/2006 13:40:00 11.6 1.7 16.8 7.6 11.6 1.8 17.6 7.2 11.4 1.8 16.4 6.8 333 8 343 165 -3.6 0 -3.5 -3.7 01/31/2006 13:50:00 10.9 1.6 14.1 6.8 10.9 1.7 14.9 6.8 10.5 1.6 13.7 6.5 338 9 338 165 -3.6 0 -3.5 -3.7 01/31/2006 14:00:00 11.9 1.5 14.9 7.6 11.9 1.5 14.9 7.2 11.6 1.5 14.5 7.6 332 9 332 165 -3.6 0 -3.5 -3.7 01/31/2006 14:10:00 11.6 1.6 15.3 7.6 11.7 1.8 15.3 7.2 11.3 1.7 16.4 7.2 339 7 351 165 -3.6 0 -3.5 -3.7 01/31/2006 14:20:00 10.7 1.3 14.1 7.6 10.7 1.5 14.5 6.8 10.4 1.3 13.7 7.2 341 7 334 165 -3.6 0 -3.5 -3.7 01/31/2006 14:30:00 10.7 1 13.7 8 10.6 1.3 13.7 5.3 10.2 1.1 13.7 7.6 340 8 333 165 -3.6 0 -3.5 -3.7 01/31/2006 14:40:00 10.7 1.3 13.7 6.5 10.5 1.6 14.1 5.7 10.4 1.3 13.7 6.1 339 9 344 165 -3.6 0 -3.5 -3.5 01/31/2006 14:50:00 10.2 1.5 13.7 5.3 9.9 1.9 13.7 4.6 9.4 1.5 13 4.9 339 11 333 165 -3.6 0 -3.5 -3.7 01/31/2006 15:00:00 10.1 1.7 14.1 5.7 9.9 1.9 14.5 4.6 9.8 1.7 15.3 4.9 341 9 348 165 -3.7 0 -3.5 -3.7 01/31/2006 15:10:00 11.5 1.5 14.9 6.8 11.5 1.8 15.3 6.1 11.1 1.6 14.1 6.5 341 8 339 165 -3.8 0 -3.5 -3.9 01/31/2006 15:20:00 10.5 1.5 15.6 6.1 10.1 1.9 15.6 5.7 10 1.6 14.9 6.1 345 10 342 165 -3.9 0 -3.7 -3.9 01/31/2006 15:30:00 10.6 1.7 15.3 6.5 10.5 1.9 14.5 5.3 10.2 1.8 13.7 5.7 343 9 345 165 -3.9 0 -3.9 -4.2 01/31/2006 15:40:00 11.1 1.5 14.5 7.6 10.9 2 15.3 5.3 10.2 1.5 14.1 6.8 340 10 349 165 -4.1 0 -3.9 -4.2 01/31/2006 15:50:00 10.7 1.6 15.6 7.2 10.4 2.1 16.1 5.7 10.3 1.7 15.6 6.5 343 8 342 165 -4.2 0 -3.9 -4.4 01/31/2006 16:00:00 11.2 1.5 15.3 7.6 11.2 1.7 15.6 7.6 10.6 1.7 14.9 6.5 341 7 348 165 -4.2 0 -4.2 -4.4 01/31/2006 16:10:00 10.8 1.7 15.6 6.5 10.8 1.8 15.6 6.1 9.9 1.7 14.5 5.3 337 8 326 165 -4.3 0 -4.2 -4.4 01/31/2006 16:20:00 12.6 2 17.2 8 12.6 2.2 17.2 7.6 11.6 2.1 16.1 6.8 339 7 334 165 -4.5 0 -4.4 -4.6 01/31/2006 16:30:00 13 1.5 16.8 8.8 12.9 1.6 16.4 7.6 12.4 1.5 16.1 8.8 341 7 340 165 -4.5 0 -4.4 -4.6 01/31/2006 16:40:00 11.1 1.5 14.1 6.8 11.1 1.5 14.9 6.8 10.3 1.6 13.7 5.7 335 7 339 165 -4.6 0 -4.4 -4.6 01/31/2006 16:50:00 12.9 1.7 17.6 8.8 13 1.7 17.9 8.8 12.3 1.6 16.8 8.8 337 7 340 165 -4.7 0 -4.6 -4.6 01/31/2006 17:00:00 13.4 1.5 16.8 9.1 13.2 1.9 17.9 6.8 12.7 1.5 16.4 8.8 338 9 336 165 -4.7 0 -4.6 -4.8 01/31/2006 17:10:00 12.6 1.3 16.1 8.8 12.7 1.5 16.1 8.8 11.6 1.5 15.6 7.6 338 8 330 165 -4.7 0 -4.6 -4.8 01/31/2006 17:20:00 12.3 1.5 16.1 9.1 12.2 1.8 16.4 6.5 11.8 1.6 16.1 8.4 340 8 332 165 -4.7 0 -4.6 -4.8 01/31/2006 17:30:00 11 1.6 14.5 7.6 11.1 1.8 15.3 6.5 10.4 1.7 14.9 6.5 341 8 343 165 -4.8 0 -4.6 -4.8 01/31/2006 17:40:00 9.6 1.3 12.2 5.3 9.5 1.5 13 5.3 8.6 1.3 11.8 4.9 341 9 347 165 -4.9 0 -4.6 -5 01/31/2006 17:50:00 9.6 1.4 13 6.1 9.3 1.7 12.6 3.8 8.7 1.3 11.5 4.9 342 10 344 165 -5 0 -4.8 -5 01/31/2006 18:00:00 10.4 1.7 14.5 6.1 10.3 1.9 14.9 5.7 9.4 1.9 14.1 5.3 338 7 334 165 -5.2 0 -5 -5.3 01/31/2006 18:10:00 11.5 1.7 17.2 7.2 11.5 1.8 17.9 6.8 10.5 1.7 15.3 6.5 343 7 350 165 -5.3 0 -5 -5.5 01/31/2006 18:20:00 11.8 1.5 15.6 6.8 11.5 2.1 16.1 6.1 11 1.6 14.9 5.7 344 7 340 165 -5.4 0 -5.3 -5.5 01/31/2006 18:30:00 11.1 1.2 13.7 7.2 11.2 1.3 14.5 7.6 10.3 1.3 13.3 6.1 343 6 347 165 -5.5 0 -5.5 -5.7 01/31/2006 18:40:00 10.1 1.3 14.1 6.8 9.7 1.7 14.5 5.3 9.3 1.3 13.7 5.7 345 7 340 165 -5.5 0 -5.5 -5.5 01/31/2006 18:50:00 8.4 0.9 11.1 5.7 8.1 1.3 10.7 3.8 7.9 0.9 9.9 5.3 342 9 346 165 -5.6 0 -5.5 -5.7 01/31/2006 19:00:00 8.1 1.2 11.1 4.9 8 1.4 11.5 4.2 7.7 1.3 10.7 4.6 335 11 333 165 -5.6 0 -5.5 -5.7 01/31/2006 19:10:00 7.9 1.3 12.2 5.3 7.5 1.2 11.1 5.3 7.2 1.5 11.5 3.8 335 12 349 165 -5.6 0 -5.5 -5.7 01/31/2006 19:20:00 9.5 1.2 12.6 5.7 9.3 1.4 13 5.3 8.6 1.3 11.5 5.3 339 8 326 165 -5.7 0 -5.5 -5.7 01/31/2006 19:30:00 8.9 1.1 11.8 5.7 8.6 1.2 11.5 4.9 8.4 1.2 11.5 5.3 340 10 356 165 -5.7 0 -5.5 -5.7 01/31/2006 19:40:00 8.6 1.3 12.6 5.7 8.4 1.3 13 5.3 8.2 1.2 11.8 5.3 337 11 349 165 -5.8 0 -5.5 -5.7 01/31/2006 19:50:00 9 1.4 12.2 5.7 8.8 1.4 12.2 4.6 8.6 1.5 12.2 4.9 338 10 349 165 -5.8 0 -5.7 -5.9 01/31/2006 20:00:00 8.4 1 11.5 6.1 8.3 1.2 11.5 4.2 8.1 1.1 11.5 4.9 341 8 332 165 -5.8 0 -5.7 -5.9 01/31/2006 20:10:00 9.4 1.3 12.6 5.7 9.3 1.5 13.7 4.9 9.1 1.5 13.3 5.7 341 9 342 165 -5.8 0 -5.7 -5.9 01/31/2006 20:20:00 9.6 1.1 12.2 6.1 9.4 1.5 13 4.2 9.1 1.3 12.6 4.6 338 12 338 165 -5.8 0 -5.7 -5.9 01/31/2006 20:30:00 9.5 1.3 13 6.8 9.3 1.5 13.3 6.1 9.2 1.4 12.6 6.1 340 9 328 165 -5.9 0 -5.7 -5.9 01/31/2006 20:40:00 6.9 1.5 11.5 4.2 6.7 1.6 11.5 3.4 6.3 1.5 10.7 3.4 340 10 335 165 -5.9 0 -5.7 -6.1 01/31/2006 20:50:00 8.1 1 11.5 5.3 8 1.1 11.8 5.3 7.8 1 11.5 5.3 335 12 313 165 -5.9 0 -5.7 -6.1 01/31/2006 21:00:00 8.9 1.6 14.1 4.9 8.7 1.7 14.1 3.8 8.5 1.4 13.7 5.3 332 12 335 165 -5.9 0 -5.7 -6.1 01/31/2006 21:10:00 10.5 1.5 13.7 6.8 10.4 1.5 14.1 6.5 10.2 1.5 14.5 6.8 333 9 340 165 -5.9 0 -5.7 -6.1 01/31/2006 21:20:00 9.3 1.2 12.6 6.8 9.3 1.2 12.6 6.5 9.1 1.2 12.2 6.1 335 10 342 165 -6 0 -5.9 -6.1 01/31/2006 21:30:00 9.2 1.3 13.3 6.5 9 1.3 13.7 6.1 8.6 1.5 13.3 4.9 337 8 334 165 -6.1 0 -5.9 -6.1 01/31/2006 21:40:00 9 1.4 12.6 5.7 8.9 1.6 13 4.2 8.6 1.3 11.8 4.9 340 10 343 165 -6.1 0 -5.9 -6.1 01/31/2006 21:50:00 9 1.5 13.7 6.1 9 1.5 13.7 6.1 8.9 1.4 12.2 5.7 333 9 333 165 -6.1 0 -5.9 -6.1 01/31/2006 22:00:00 9.6 1.3 12.6 6.5 9.5 1.3 12.2 6.1 9.5 1.4 13.3 6.1 335 9 348 165 -6.1 0 -5.9 -6.1 01/31/2006 22:10:00 10.4 1.2 13.7 5.3 10 1.7 14.1 4.6 10.6 1.3 13.7 6.8 340 12 338 165 -6.1 0 -5.9 -6.1 01/31/2006 22:20:00 10 1.9 13.7 3 9.5 2.1 13.7 3.4 9.8 2 13.7 2.6 337 14 340 165 -6.1 0 -5.9 -6.1 01/31/2006 22:30:00 9.5 1.4 14.5 6.5 9 1.7 14.5 5.3 9.2 1.4 13.3 5.7 339 13 345 165 -6.1 0 -5.9 -6.1 01/31/2006 22:40:00 8.6 1.5 13.3 5.3 8.4 1.6 13 4.9 8.6 1.5 14.5 5.3 336 10 348 165 -6.2 0 -6.1 -6.4 01/31/2006 22:50:00 8.7 1.7 13 5.7 7.9 1.8 13 4.2 8.6 1.7 14.9 4.9 341 15 356 165 -6.1 0 -6.1 -6.4 01/31/2006 23:00:00 8.2 1.2 11.1 4.9 8.1 1.1 11.1 4.2 8.1 1.2 11.5 4.9 330 11 346 165 -6.3 0 -6.1 -6.4 01/31/2006 23:10:00 8.9 1.4 11.8 5.7 8.6 1.6 12.2 4.2 8.7 1.5 13 5.3 336 13 344 165 -6.2 0 -6.1 -6.4 01/31/2006 23:20:00 7 2 11.8 2.3 6.9 2 11.5 2.3 6.9 1.7 11.5 3.4 332 13 329 165 -6.3 0 -6.1 -6.4 01/31/2006 23:30:00 7.4 0.9 9.9 4.2 7.3 0.8 9.9 4.6 6.9 1 9.5 4.6 319 17 301 165 -6.4 0 -6.1 -6.6 01/31/2006 23:40:00 7.6 1.2 11.1 4.9 7.5 1.2 11.1 4.9 6.5 1.3 10.7 3.4 305 15 287 165 -6.4 0 -6.1 -6.6 01/31/2006 23:50:00 8.4 1 10.7 5.7 8.3 1 11.1 5.3 7.9 1.1 10.3 3.8 323 15 328 165 -6.5 0 -6.4 -6.6 02/01/2006 00:00:00 7.7 1.3 11.1 4.6 7.6 1.3 11.1 4.9 6.8 1.2 9.5 3.8 312 13 297 165 -6.6 0 -6.4 -6.8 02/01/2006 00:10:00 8.3 1.2 12.2 5.3 8.2 1.1 11.8 4.9 8 1.3 12.6 5.3 321 13 327 165 -6.5 0 -6.4 -6.6 02/01/2006 00:20:00 8.1 1 11.1 6.1 8 1.1 11.1 5.7 8 1 10.7 5.7 333 11 341 165 -6.7 0 -6.6 -6.8 02/01/2006 00:30:00 8.3 1.2 12.2 5.3 8.2 1.2 11.8 5.7 7.7 1 11.1 5.3 319 12 307 165 -6.7 0.1 -6.4 -6.8 02/01/2006 00:40:00 7.9 1.4 13.3 4.9 7.6 1.3 11.5 4.9 7.7 1.3 11.8 4.6 336 13 353 165 -6.7 0.2 -6.4 -6.8 02/01/2006 00:50:00 8.8 1.5 13 5.3 8.2 1.3 12.6 4.6 9 1.5 13.7 6.1 338 15 356 165 -6.9 0 -6.6 -7 02/01/2006 01:00:00 8.1 1.3 12.2 4.9 8 1.3 12.2 4.6 8.1 1.1 11.5 5.3 335 11 354 165 -6.8 0.1 -6.6 -6.8 02/01/2006 01:10:00 9.4 1.4 13 6.1 9.3 1.4 13.3 5.7 8.9 1.3 12.2 5.7 317 11 302 165 -6.6 0 -6.6 -6.8 02/01/2006 01:20:00 8.7 1.2 13.3 5.7 8.6 1.2 13.3 5.7 8.5 1.1 11.8 5.3 322 13 290 165 -6.6 0 -6.4 -6.8 02/01/2006 01:30:00 10.1 1.3 14.1 6.5 10 1.3 13.7 6.1 9.3 1.5 14.5 5.7 314 11 297 165 -6.6 0 -6.4 -6.8 02/01/2006 01:40:00 10.1 1.5 14.5 5.7 10 1.5 14.1 5.3 9.1 1.5 13.3 5.7 312 12 296 165 -6.4 0 -6.1 -6.6 02/01/2006 01:50:00 9.2 1.4 13.7 6.1 9.1 1.3 13 6.1 8.3 1.5 12.6 4.2 311 9 310 165 -6.4 0 -6.1 -6.6 02/01/2006 02:00:00 7.3 1 9.9 4.2 7.2 0.9 9.9 4.6 7.2 0.9 9.9 4.9 324 9 318 165 -6.6 0 -6.4 -6.8 02/01/2006 02:10:00 7.1 0.7 8.8 4.9 7 0.7 9.1 4.9 6.7 0.7 8.4 4.9 317 6 312 165 -6.9 0.1 -6.6 -7 02/01/2006 02:20:00 6.6 0.7 8.4 4.9 6.5 0.7 8.8 4.9 6 0.8 8.4 3.4 315 9 317 165 -6.9 0 -6.8 -7 02/01/2006 02:30:00 7.8 1 11.1 5.3 7.7 1 10.7 5.3 6.3 1 9.5 4.2 306 6 306 165 -6.9 0 -6.8 -7 02/01/2006 02:40:00 9 0.7 11.1 7.2 8.9 0.7 11.1 7.2 8.3 1 10.3 4.9 316 7 310 165 -6.9 0 -6.8 -7 02/01/2006 02:50:00 9.7 0.9 11.8 7.6 9.6 0.9 11.8 7.2 9.1 0.9 11.5 6.5 317 6 323 165 -6.9 0 -6.8 -7 02/01/2006 03:00:00 9.1 0.7 11.1 7.2 8.9 0.7 10.7 7.2 8.6 0.8 11.5 5.7 317 5 313 165 -7 0 -6.8 -7 02/01/2006 03:10:00 9 0.6 11.1 7.2 8.8 0.7 11.1 7.2 8.4 0.6 9.9 6.1 317 5 310 165 -6.9 0 -6.8 -7 02/01/2006 03:20:00 8.4 1 11.5 5.7 8.3 1 11.1 5.7 7.9 1.2 11.1 5.3 318 5 311 165 -7 0 -6.8 -7.2 02/01/2006 03:30:00 8.6 0.7 10.7 6.8 8.4 0.7 10.3 6.8 8.2 0.7 9.9 6.1 317 6 312 165 -6.9 0 -6.8 -7 02/01/2006 03:40:00 8.9 1 11.1 6.1 8.8 1 11.1 6.1 8.7 1.1 11.5 5.7 330 8 322 165 -6.8 0 -6.6 -7.2 02/01/2006 03:50:00 8 0.6 9.9 6.5 7.9 0.6 9.9 6.5 7.4 0.7 9.1 5.3 315 6 307 165 -6.9 0 -6.8 -7 02/01/2006 04:00:00 8.5 0.9 10.7 6.8 8.4 0.9 10.7 6.5 7.8 1 10.7 5.7 315 7 301 165 -6.9 0 -6.8 -7 02/01/2006 04:10:00 7.7 0.7 9.9 5.7 7.6 0.7 9.9 4.9 7.2 0.8 9.1 5.3 320 9 312 165 -7 0 -6.8 -7.2 02/01/2006 04:20:00 7 1 9.9 4.9 7 1 10.3 4.9 6.6 1 9.1 4.6 321 8 310 165 -7 0 -6.8 -7.2 02/01/2006 04:30:00 8 0.9 10.7 6.1 7.9 0.9 11.1 6.1 7.4 1 11.1 4.9 317 8 332 165 -6.9 0 -6.8 -7.2 02/01/2006 04:40:00 7.9 1 10.7 5.7 7.8 1 10.7 5.3 7.5 0.9 10.3 5.7 318 8 314 165 -6.9 0 -6.8 -7.2 02/01/2006 04:50:00 8.1 0.9 11.1 6.1 8.1 0.9 11.5 6.1 7.6 1 11.1 5.3 320 10 307 165 -7.1 0 -6.8 -7.2 02/01/2006 05:00:00 7.8 1.1 10.7 4.9 7.6 1.1 10.7 4.9 7.3 1.3 12.2 4.6 320 6 311 165 -7.3 0.1 -7 -7.6 02/01/2006 05:10:00 7.6 1.1 10.3 3.8 7.5 1 9.9 4.2 6.8 1.3 9.5 2.6 316 8 312 165 -7.6 0 -7.4 -7.6 02/01/2006 05:20:00 6.4 1.1 9.1 3.4 6.3 1.1 9.1 3.4 5.7 1.2 9.1 3 319 10 318 165 -7.6 0.1 -7.4 -7.6 02/01/2006 05:30:00 5.6 0.8 8 3.8 5.6 0.8 7.6 3.8 5 0.8 6.8 2.6 320 10 316 165 -7.6 0 -7.2 -7.9 02/01/2006 05:40:00 6.5 1.2 9.1 3.4 6.4 1.2 9.1 3.4 6 1.3 8.4 2.6 329 9 338 165 -7.8 0 -7.4 -8.1 02/01/2006 05:50:00 6.1 1 8.4 3.4 6 1 9.1 3.8 5.6 1 7.6 3.4 333 9 353 165 -7.6 0.1 -7.4 -7.9 02/01/2006 06:00:00 6.4 1.2 9.5 3 6.3 1.3 9.9 3.4 6.2 1.3 9.1 3 336 11 346 165 -7.6 0.1 -7.2 -7.9 02/01/2006 06:10:00 7.9 1 10.7 4.9 7.1 1.5 10.7 3.4 7.7 1 10.3 4.9 348 8 0 165 -7.6 0 -7.4 -7.6 02/01/2006 06:20:00 8 1.3 11.8 5.3 7.4 1.3 12.6 3.4 7.8 1.4 11.1 3.8 344 10 345 165 -7.8 0 -7.6 -8.1 02/01/2006 06:30:00 7.3 1 10.3 5.3 6.8 1.1 9.9 3 7.2 1.1 10.7 4.9 345 9 350 165 -8 0 -7.6 -8.1 02/01/2006 06:40:00 7.7 1.3 10.7 4.6 6.7 1.6 10.7 3 7.1 1.4 10.7 3.4 350 11 352 165 -8.1 0 -8.1 -8.3 02/01/2006 06:50:00 7.1 1 9.5 4.6 6.1 1.2 9.9 3.4 6.6 1.1 9.1 3.4 349 11 353 165 -8.2 0 -8.1 -8.3 02/01/2006 07:00:00 4.5 1.3 7.2 1.1 4 1.1 7.6 1.1 4 1.6 7.6 0.4 340 17 354 165 -8.1 0 -8.1 -8.3 02/01/2006 07:10:00 2.9 1.8 7.2 0.4 2.8 1.7 7.6 0.4 2.5 1.7 6.1 0.4 326 76 355 165 -8.3 0 -8.1 -8.5 02/01/2006 07:20:00 3.6 2 8 0.4 3.5 2 8 0.4 2.7 1.7 6.5 0.4 333 41 305 165 -8.2 0 -8.1 -8.5 02/01/2006 07:30:00 5.4 1.9 10.3 2.3 5.4 1.9 10.3 2.3 4.6 2 9.9 1.1 320 15 320 165 -8.1 0 -8.1 -8.3 02/01/2006 07:40:00 9.1 1.2 12.2 6.1 9.1 1.2 11.8 6.1 8.3 1.3 11.5 4.9 319 9 325 165 -8 0 -7.6 -8.1 02/01/2006 07:50:00 7.9 1.2 12.2 4.6 7.8 1.2 12.2 4.6 6.7 1.4 11.1 2.6 321 14 332 165 -8.1 0 -8.1 -8.3 02/01/2006 08:00:00 8.8 1.3 11.8 4.9 8.7 1.3 11.8 4.9 8.1 1.3 11.5 4.6 327 9 334 165 -8.2 0 -8.1 -8.5 02/01/2006 08:10:00 10.7 1.5 13.7 6.8 10.6 1.4 13.7 6.5 10.2 1.5 13.3 6.5 323 8 325 165 -8.3 0 -8.1 -8.5 02/01/2006 08:20:00 11 0.8 13 8.8 10.9 0.8 12.6 8.8 10.7 1 13.7 8 322 6 317 165 -8.3 0 -8.3 -8.5 02/01/2006 08:30:00 10.5 1 12.6 7.2 10.3 1 12.6 6.8 10 1 12.2 6.8 319 7 310 165 -8.5 0.1 -8.3 -8.5 02/01/2006 08:40:00 10.6 0.7 12.6 8.8 10.5 0.7 12.6 8.8 9.2 1 11.8 6.1 311 7 297 165 -8.7 0 -8.5 -8.9 02/01/2006 08:50:00 11.5 0.9 13.7 9.1 11.4 0.9 13.3 9.1 10.6 1 13 8 315 9 313 165 -8.9 0 -8.7 -9.1 02/01/2006 09:00:00 11.3 0.8 13.7 9.5 11.3 0.7 13.3 9.1 10.1 1.3 13 6.8 311 5 313 165 -9.1 0 -8.9 -9.3 02/01/2006 09:10:00 10.1 0.8 11.8 7.6 10 0.9 11.5 7.6 9.2 1 11.1 6.8 311 5 308 165 -9.1 0 -9.1 -9.3 02/01/2006 09:20:00 10.6 1.2 13.7 8.4 10.6 1.2 13.3 8 9.1 1 11.8 6.1 310 5 302 165 -9.2 0 -9.1 -9.3 02/01/2006 09:30:00 11.9 0.8 14.5 9.1 11.8 0.8 13.7 9.1 9.7 1.2 12.6 6.8 308 5 305 165 -9.5 0.1 -9.3 -9.7 02/01/2006 09:40:00 11.7 1 14.1 8.8 11.6 1 14.1 9.1 10.8 1.2 13.3 8 313 4 315 165 -9.7 0 -9.5 -9.7 02/01/2006 09:50:00 12.4 1.1 14.5 8.8 12.3 1.1 14.5 8.4 11.9 1.2 14.9 7.6 315 5 315 165 -9.7 0 -9.5 -9.7 02/01/2006 10:00:00 12 1 14.5 9.5 12 1 14.5 9.5 11.3 1 13.7 8.4 314 5 311 165 -9.7 0 -9.7 -9.7 02/01/2006 10:10:00 11 1 13.3 8 10.9 1.1 13.7 8 10.4 1.2 13.7 7.2 316 6 318 165 -9.7 0 -9.7 -10 02/01/2006 10:20:00 11.6 1.2 14.1 7.6 11.5 1.1 14.1 7.6 11.1 1.1 13.3 7.2 316 5 311 165 -9.6 0 -9.5 -9.7 02/01/2006 10:30:00 11.6 1.1 14.5 8.4 11.5 1.1 14.1 8.4 10.9 1.2 13.7 7.2 315 5 313 165 -9.5 0 -9.3 -9.7 02/01/2006 10:40:00 11.1 0.9 13.7 8.4 11 0.9 13.3 8.8 10.1 1.1 13.3 7.2 313 5 309 165 -9.3 0 -9.1 -9.5 02/01/2006 10:50:00 11.4 0.7 13 9.1 11.2 0.7 13 9.1 10.3 1 12.6 7.2 313 5 310 165 -9.3 0 -9.1 -9.5 02/01/2006 11:00:00 11.5 1 13.7 8.8 11.3 1 13.3 8.4 10.1 1 13.3 7.2 311 4 309 165 -9.2 0 -9.1 -9.3 02/01/2006 11:10:00 11.7 0.9 14.1 9.1 11.6 1 13.7 8.8 10.7 1.1 13.3 8 314 4 308 165 -9.3 0 -9.1 -9.3 02/01/2006 11:20:00 11 1 13.7 7.6 10.9 1 13.3 8 10.1 1.2 13 7.2 313 5 304 165 -9.2 0 -8.9 -9.3 02/01/2006 11:30:00 11.2 1.2 14.1 8.4 11.1 1.2 13.7 8.4 10.3 1.4 13 6.5 315 6 316 165 -9.1 0 -8.9 -9.3 02/01/2006 11:40:00 8 1.3 13.3 5.3 7.9 1.4 13.3 5.3 7.2 1.3 12.6 4.6 314 10 313 165 -8.8 0.2 -8.5 -9.1 02/01/2006 11:50:00 8.1 1.3 11.5 4.2 8 1.3 11.5 3.8 6.7 1.2 10.3 3.8 303 11 318 165 -8.6 0.1 -8.3 -8.9 02/01/2006 12:00:00 7.2 0.9 9.5 4.6 7.2 0.9 9.5 4.2 6.3 1 9.1 3.4 310 10 297 165 -8.4 0.1 -8.1 -8.7 02/01/2006 12:10:00 7.8 1.7 12.2 4.6 7.8 1.7 12.2 4.6 7.5 1.6 12.2 4.6 316 9 313 165 -8.8 0 -8.5 -8.9 02/01/2006 12:20:00 9.8 1.5 13.7 6.1 9.7 1.5 13.7 5.7 8.9 1.5 12.6 4.9 313 8 306 165 -8.8 0 -8.5 -9.1 02/01/2006 12:30:00 10.6 1 13 8.4 10.6 1 13 8.4 9.3 1.3 12.6 6.1 310 5 309 165 -9.1 0 -8.9 -9.3 02/01/2006 12:40:00 10.6 1.3 13.7 7.6 10.6 1.3 14.1 7.2 9.1 1.5 13 5.3 308 5 305 165 -9.1 0 -8.9 -9.3 02/01/2006 12:50:00 11.5 0.8 14.1 9.1 11.4 0.9 14.1 9.1 11 1.2 14.5 7.2 316 7 312 165 -9 0 -8.9 -9.3 02/01/2006 13:00:00 11.8 0.9 14.1 9.9 11.7 0.9 14.1 9.5 11.1 1.3 14.1 7.2 316 8 305 165 -9.1 0 -8.9 -9.1 02/01/2006 13:10:00 12.1 1.1 15.6 9.5 12 1 15.3 9.5 11.2 1.5 14.5 6.8 315 9 311 165 -9.1 0.1 -8.9 -9.3 02/01/2006 13:20:00 12.3 1.2 14.9 9.5 12.2 1.2 14.5 9.1 11.5 1.3 14.5 8 314 7 302 165 -9.2 0 -9.1 -9.3 02/01/2006 13:30:00 11.5 1.1 14.5 9.1 11.4 1.1 14.5 9.1 11.2 1.3 14.5 8 318 7 316 165 -9.2 0 -8.9 -9.3 02/01/2006 13:40:00 10.5 1.2 13.7 7.6 10.4 1.2 13.7 7.6 9.4 1.4 13.3 4.9 313 8 313 165 -9.2 0.1 -8.9 -9.3 02/01/2006 13:50:00 9.9 1.2 13.7 6.8 9.8 1.2 13.3 6.8 9.6 1.4 13.3 6.1 320 7 317 165 -9.1 0 -8.9 -9.3 02/01/2006 14:00:00 11.5 1.2 14.5 7.2 11.5 1.2 14.1 7.2 9.6 1.3 12.6 6.5 310 7 305 165 -9.4 0.2 -9.1 -9.7 02/01/2006 14:10:00 13.5 1.2 16.8 9.9 13.4 1.3 16.4 9.9 11.9 1.5 16.1 7.6 310 6 310 165 -9.6 0 -9.3 -9.7 02/01/2006 14:20:00 13.4 1.2 16.8 9.9 13.3 1.2 16.8 10.3 11.4 1.6 15.6 7.6 308 7 304 165 -9.6 0 -9.5 -9.7 02/01/2006 14:30:00 13.7 1.5 16.8 8.8 13.6 1.6 16.8 9.1 11 1.7 15.3 6.8 306 6 305 165 -9.7 0 -9.5 -10 02/01/2006 14:40:00 13 1.2 15.6 9.9 12.9 1.2 16.1 9.5 11 1.3 14.1 7.6 309 6 305 165 -9.7 0 -9.7 -10 02/01/2006 14:50:00 12.8 1.2 15.6 9.5 12.7 1.1 15.6 9.5 10.6 1.7 14.9 7.6 307 7 310 165 -9.8 0 -9.7 -10.2 02/01/2006 15:00:00 14.6 1.3 17.2 10.7 14.5 1.4 17.2 10.7 11.4 1.7 16.1 8 306 4 307 165 -10.1 0.1 -9.7 -10.2 02/01/2006 15:10:00 16.2 0.9 18.3 13 16.1 0.9 18.3 13.3 14.9 1.3 19.1 9.9 311 4 308 165 -10.2 0 -10.2 -10.4 02/01/2006 15:20:00 15.5 1.3 18.7 11.5 15.5 1.3 17.9 11.1 13.4 2 17.9 9.1 308 6 319 165 -10.4 0 -10.2 -10.6 02/01/2006 15:30:00 14.3 1 16.4 11.1 14.2 1 16.4 11.5 11.9 1.8 16.4 7.2 307 5 304 165 -10.5 0 -10.4 -10.6 02/01/2006 15:40:00 14.6 1.5 20.2 11.5 14.6 1.5 20.2 11.1 12.6 2.7 19.5 8 308 6 302 165 -10.7 0.1 -10.6 -11 02/01/2006 15:50:00 16 1.3 18.7 11.8 15.9 1.3 18.7 12.2 14.3 1.7 18.7 9.1 309 5 309 165 -11 0 -10.8 -11.2 02/01/2006 16:00:00 16.1 1.3 20.2 13 16 1.4 20.2 12.6 12 1.5 18.3 8.8 300 6 299 165 -11 0.1 -11 -11.4 02/01/2006 16:10:00 16.6 1.3 19.5 13.3 16.5 1.4 19.5 12.6 12.3 1.4 17.2 9.5 297 5 300 165 -11.3 0 -11 -11.4 02/01/2006 16:20:00 15.9 1.5 19.5 11.8 15.8 1.6 19.9 11.8 12.8 1.6 17.9 8.8 303 6 308 165 -11.4 0 -11.2 -11.6 02/01/2006 16:30:00 14.9 1.7 17.9 9.5 14.8 1.7 17.9 10.3 12.4 1.8 17.2 7.6 303 7 300 165 -11.5 0 -11.4 -11.8 02/01/2006 16:40:00 16.2 1.2 19.1 13 16.1 1.2 19.1 12.6 12 1.1 15.3 8.8 298 4 297 165 -11.6 0 -11.6 -11.8 02/01/2006 16:50:00 16.8 0.9 18.7 13.7 16.7 1 18.7 13 12.8 1.1 16.1 9.9 301 3 299 165 -11.8 0.1 -11.6 -11.8 02/01/2006 17:00:00 17.1 1.2 19.9 14.5 17 1.2 19.9 14.5 13.5 1.7 17.9 9.5 304 4 299 165 -11.9 0 -11.8 -12 02/01/2006 17:10:00 16.3 1.1 18.7 13.7 16.2 1.1 19.1 13.3 13.7 1.5 17.2 9.9 308 5 302 165 -12 0 -11.8 -12.2 02/01/2006 17:20:00 15.6 1.1 17.6 12.6 15.5 1.1 17.6 12.2 14.2 1.1 17.9 10.3 312 4 310 165 -12.2 0 -12 -12.2 02/01/2006 17:30:00 12.6 1.4 15.6 8 12.5 1.3 15.3 8 11.5 1.3 14.9 8 313 5 309 165 -12.4 0.1 -12.2 -12.6 02/01/2006 17:40:00 10.4 1.2 13 6.5 10.2 1.1 13 6.8 9.9 1.1 13 6.8 319 7 308 165 -12.7 0.1 -12.4 -13 02/01/2006 17:50:00 10.5 0.8 12.2 8.4 10.4 0.8 11.8 7.6 10.3 1 12.2 7.6 322 6 322 165 -12.7 0 -12.4 -13 02/01/2006 18:00:00 9.3 1.1 11.8 6.1 9.2 1.1 11.5 6.1 9.2 1.2 11.8 5.7 323 8 317 165 -12.7 0.1 -12.4 -13 02/01/2006 18:10:00 9.6 0.8 12.2 8 9.5 0.8 12.2 7.6 9.4 0.8 11.5 7.6 317 5 310 165 -12.8 0 -12.6 -13 02/01/2006 18:20:00 10 0.8 11.8 8 9.9 0.8 11.5 8 9.5 0.8 11.5 7.2 313 5 307 165 -12.9 0 -12.6 -13 02/01/2006 18:30:00 9.6 0.9 11.5 6.8 9.5 0.9 11.8 6.8 8 1 10.7 5.3 308 6 307 165 -13.1 0 -12.8 -13.2 02/01/2006 18:40:00 7.5 1.4 11.5 4.6 7.4 1.4 11.8 4.6 7.2 1.5 10.7 4.2 324 9 334 165 -13.4 0 -13.2 -13.6 02/01/2006 18:50:00 8.4 1 11.8 6.1 8.3 1 11.5 5.7 8.1 1.2 11.1 4.2 318 8 315 165 -13.2 0 -13 -13.4 02/01/2006 19:00:00 10.4 1.5 14.1 5.7 10.3 1.6 13.7 6.1 9.2 1.4 12.2 5.7 311 7 300 165 -13.2 0 -13 -13.4 02/01/2006 19:10:00 13.1 1.6 17.6 9.9 13.1 1.6 17.6 9.5 11.1 1.9 16.8 6.8 305 9 307 165 -13 0.1 -12.6 -13.2 02/01/2006 19:20:00 15.6 1.9 19.1 10.7 15.6 1.9 19.1 9.9 11.9 1.8 17.9 7.2 302 7 297 165 -12.7 0 -12.4 -13 02/01/2006 19:30:00 15.2 1.7 18.7 11.1 15.1 1.7 19.1 11.1 10.9 1.5 16.1 7.6 300 6 291 165 -12.7 0 -12.6 -13 02/01/2006 19:40:00 13 1.7 17.6 8.4 12.9 1.7 17.6 7.6 10.1 1.5 15.3 6.5 299 8 292 165 -12.6 0 -12.4 -13 02/01/2006 19:50:00 12 1.5 15.3 8 11.9 1.5 15.3 8 9.5 1.1 12.6 6.8 304 6 309 165 -12.8 0 -12.6 -13 02/01/2006 20:00:00 12.5 1.5 16.4 8.4 12.4 1.5 16.1 8 9.1 1.3 12.6 5.7 303 5 301 165 -12.7 0 -12.4 -13 02/01/2006 20:10:00 12.7 1.3 16.4 10.3 12.6 1.3 16.4 10.3 10.3 1.6 15.3 6.8 306 7 307 165 -12.6 0 -12.4 -12.6 02/01/2006 20:20:00 13.9 1.7 18.7 10.7 13.8 1.7 18.7 10.7 11.2 1.6 15.3 6.8 306 6 301 165 -12.8 0 -12.6 -13 02/01/2006 20:30:00 13.7 1 16.4 10.3 13.6 1.1 15.6 10.7 11 1.5 15.3 8 306 5 300 165 -12.9 0 -12.6 -13 02/01/2006 20:40:00 13.1 1 15.3 9.9 13 1 14.9 9.9 11.3 1.5 14.5 7.6 309 6 299 165 -12.8 0 -12.6 -13 02/01/2006 20:50:00 12.5 1.4 15.3 8.8 12.3 1.4 14.9 8.4 10.6 1.3 13.7 7.2 309 6 298 165 -12.7 0 -12.6 -13 02/01/2006 21:00:00 13.8 1.7 17.6 9.1 13.7 1.7 17.6 8.8 10.6 1.4 13.7 7.6 305 6 299 165 -12.5 0.1 -12.4 -12.8 02/01/2006 21:10:00 14.6 1.2 17.6 10.3 14.5 1.2 17.6 10.3 11.5 1.6 16.1 7.6 305 6 301 165 -12.5 0 -12.4 -12.6 02/01/2006 21:20:00 15.1 1.5 17.9 11.5 15 1.5 17.9 11.5 12.1 1.5 18.7 9.1 306 5 302 165 -12.5 0.1 -12.2 -12.6 02/01/2006 21:30:00 13.1 1.6 16.8 8.8 13 1.6 16.8 8.4 10.5 1.3 14.5 6.8 306 6 295 165 -12.4 0 -12.2 -12.6 02/01/2006 21:40:00 13.4 1.7 16.8 7.6 13.3 1.7 16.8 7.6 9.9 1.2 14.1 6.5 301 5 307 165 -12.3 0 -12 -12.6 02/01/2006 21:50:00 14.9 1.2 17.2 11.5 14.8 1.2 17.2 11.1 10.7 1.2 14.5 8.4 302 5 302 165 -12.1 0 -12 -12.4 02/01/2006 22:00:00 13.9 1.5 16.8 10.3 13.9 1.5 16.8 9.9 10.7 1.5 15.3 7.6 302 6 301 165 -12.4 0 -12.2 -12.6 02/01/2006 22:10:00 12.7 1.1 15.3 9.5 12.6 1.1 15.3 9.1 9.3 1.2 14.1 6.5 299 6 300 165 -12.5 0 -12.4 -12.6 02/01/2006 22:20:00 10.9 1.3 15.3 7.2 10.8 1.3 15.6 7.2 8.6 1.3 13.7 6.1 302 8 288 165 -12.6 0 -12.4 -12.6 02/01/2006 22:30:00 11.6 1.5 14.5 8 11.5 1.5 14.5 8 8.7 1.4 13 5.3 299 7 291 165 -12.5 0 -12.4 -12.8 02/01/2006 22:40:00 11.3 1.2 14.5 8.4 11.2 1.2 14.5 8.4 8.7 1.4 13.3 5.7 300 8 275 165 -12.8 0.1 -12.6 -13.2 02/01/2006 22:50:00 11.2 1 13.3 7.6 11.1 1 13.3 7.6 9.8 1.2 12.6 6.8 308 6 304 165 -13 0.1 -12.6 -13.2 02/01/2006 23:00:00 10.8 0.8 13 8 10.7 0.8 13.3 7.6 9.6 1.3 12.6 6.5 308 6 310 165 -13 0 -13 -13.2 02/01/2006 23:10:00 11.1 1 13.3 8.8 11 1 13 8.4 9.4 1.3 13 6.5 308 5 315 165 -13.1 0 -13 -13.4 02/01/2006 23:20:00 10 1.4 13.7 7.2 9.9 1.4 13.3 6.8 8.1 1.5 13 4.9 308 8 302 165 -13 0 -12.8 -13.4 02/01/2006 23:30:00 9.4 0.6 10.7 8 9.3 0.6 10.7 7.6 6.6 0.7 8.8 4.9 302 4 294 165 -13 0 -12.8 -13.2 02/01/2006 23:40:00 10 0.8 11.8 8 9.9 0.7 11.8 8 7.4 0.9 9.9 4.9 298 7 301 165 -13.1 0 -13 -13.2 02/01/2006 23:50:00 10.6 0.8 13.7 8.8 10.6 0.8 13.7 9.1 9.3 1.2 12.2 6.1 288 5 282 165 -13 0.1 -12.6 -13.2 02/02/2006 00:00:00 8.9 1.2 11.8 5.7 8.9 1.2 11.8 5.7 7.4 1.2 11.1 3.4 291 6 291 165 -12.8 0.1 -12.6 -13.2 02/02/2006 00:10:00 8.9 0.9 11.1 6.8 8.8 0.9 11.1 6.5 6.6 0.9 9.5 4.6 296 6 290 165 -13.2 0 -13.2 -13.4 02/02/2006 00:20:00 7.3 1.2 10.3 3.8 7.3 1.2 10.3 4.2 5.9 1.2 8.8 2.6 290 7 291 165 -13.6 0.2 -13.2 -14 02/02/2006 00:30:00 5.3 1.7 9.1 0.4 5.8 1.8 9.1 0.4 4.8 1.7 8.8 0.4 273 20 272 165 -13.9 0 -13.6 -14 02/02/2006 00:40:00 4.1 2 9.1 0.7 4.5 2.3 9.5 0.4 3.7 2.1 8.8 0.4 284 82 280 165 -13.7 0 -13.6 -14 02/02/2006 00:50:00 4.4 2 7.6 0.4 4.7 2.2 8.4 0.4 4.4 1.9 8.8 0.4 292 76 281 165 -13.7 0 -13.6 -14 02/02/2006 01:00:00 5.2 1.4 8.8 1.9 5.7 1.3 8.8 1.9 4.7 1.3 7.6 1.1 269 19 297 165 -13.8 0 -13.6 -14 02/02/2006 01:10:00 5.3 1.5 8.8 1.1 5.7 1.6 9.9 1.5 4.7 1.7 8.4 1.1 271 43 274 165 -13.5 0 -13.2 -13.8 02/02/2006 01:20:00 3.5 1.7 8.8 0.4 3.7 1.8 9.1 0.4 3.3 1.7 8.8 0.4 265 49 284 165 -13.3 0 -13.2 -13.6 02/02/2006 01:30:00 3.7 1.7 8.4 0.4 3.9 1.7 8.4 0.4 3.5 1.5 6.8 0.4 234 39 237 165 -13.5 0.1 -13.2 -13.6 02/02/2006 01:40:00 5 1.9 8.8 0.4 5.2 1.9 8.8 0.4 4.5 2 8.4 0.4 279 41 282 165 -13.4 0 -13.2 -13.6 02/02/2006 01:50:00 4 1.7 8 0.4 4.2 1.7 8 0.4 4.1 1.7 7.6 0.4 248 36 233 165 -13.4 0.1 -13.2 -13.6 02/02/2006 02:00:00 2.1 1.2 5.7 0.4 2.1 1.2 5.7 0.4 1.9 1.1 5.3 0.4 182 79 135 165 -13.5 0 -13.2 -13.6 02/02/2006 02:10:00 3.3 1.4 6.5 0.7 3.5 1.4 6.5 0.7 2.7 1.3 6.1 0.4 282 17 278 165 -13.6 0.1 -13.2 -13.8 02/02/2006 02:20:00 8.1 1 10.7 4.6 8.1 0.9 10.7 4.9 6.9 0.9 9.9 3.8 287 7 296 165 -13.6 0.1 -13.2 -13.8 02/02/2006 02:30:00 9.3 0.6 11.1 7.6 9.2 0.7 11.1 6.8 6.8 0.9 9.1 4.9 301 7 291 165 -13.1 0 -13 -13.2 02/02/2006 02:40:00 9.4 0.6 11.1 8 9.4 0.6 11.5 8 7.2 1 9.9 4.9 305 4 301 165 -13.3 0 -13.2 -13.4 02/02/2006 02:50:00 10.7 1 13 8 10.6 1 13.3 8 9.3 1.3 12.2 4.9 304 9 311 165 -12.9 0.2 -12.4 -13.4 02/02/2006 03:00:00 9.6 1.6 13.7 6.5 9.5 1.6 13.7 6.5 7.9 1.6 12.6 4.9 308 8 294 165 -12.8 0.2 -12.4 -13.6 02/02/2006 03:10:00 12 1.7 14.9 8 11.8 1.7 14.9 8 8.3 1 10.7 5.7 300 4 300 165 -13.6 0.1 -13.4 -13.8 02/02/2006 03:20:00 13.5 0.5 14.9 12.2 13.4 0.5 14.9 12.2 9.3 1.2 13.3 6.8 298 3 298 165 -13.5 0.1 -13.2 -13.8 02/02/2006 03:30:00 12.2 1.9 17.2 8.8 12.1 2 17.2 8.4 9.1 2.2 16.1 5.7 299 6 291 165 -13.4 0.3 -12.8 -14 02/02/2006 03:40:00 8.5 0.9 10.7 6.1 8.4 0.9 11.1 6.1 6.8 1 9.5 3.8 300 9 299 165 -14.3 0 -14 -14.6 02/02/2006 03:50:00 9.3 0.7 10.7 6.8 9.2 0.7 11.1 6.5 7.7 1.2 10.7 4.6 289 5 278 165 -14.2 0.1 -14 -14.6 02/02/2006 04:00:00 9.7 0.9 11.5 6.5 9.8 1 11.8 6.1 8.4 1.3 11.5 4.9 287 7 290 165 -14 0 -13.8 -14.2 02/02/2006 04:10:00 8.3 1.3 11.8 6.1 8.2 1.4 11.8 5.7 6.3 1.5 10.7 3.8 297 6 294 165 -14.2 0 -14 -14.6 02/02/2006 04:20:00 9.9 1 11.8 7.2 9.9 1 11.8 7.6 7.9 1.4 11.8 4.9 293 6 299 165 -14.3 0 -14 -14.6 02/02/2006 04:30:00 10.3 0.9 13 7.6 10.3 0.9 12.6 7.6 8.5 1.5 12.6 4.9 291 6 277 165 -14.2 0 -14 -14.4 02/02/2006 04:40:00 9.6 1.4 13.7 6.1 9.5 1.4 13.7 6.1 7.8 1.7 12.6 4.6 292 8 285 165 -14.2 0.1 -14 -14.6 02/02/2006 04:50:00 6.2 2.1 11.5 2.6 6.2 2.1 11.1 2.6 5.2 2 10.7 1.1 298 13 277 165 -14.1 0 -14 -14.4 02/02/2006 05:00:00 5.4 1.4 9.9 2.6 5.3 1.3 9.9 2.6 4.4 1.2 8.4 1.9 301 15 299 165 -14.4 0 -14 -14.6 02/02/2006 05:10:00 7.3 1.4 10.3 3.4 7.3 1.4 10.3 3.4 6.5 1.5 9.9 3 312 9 307 165 -14.5 0 -14.2 -14.6 02/02/2006 05:20:00 6.3 1 8.8 2.6 6.2 1 8.8 2.3 6 1 8.4 3 316 11 319 165 -14.5 0 -14.4 -14.6 02/02/2006 05:30:00 10.6 1.6 14.1 5.3 10.6 1.7 14.5 5.3 8.8 2 14.5 4.2 292 9 290 165 -14.2 0.1 -14 -14.6 02/02/2006 05:40:00 13.3 1 15.6 9.1 13.4 1.1 16.1 9.1 12 1.8 15.6 6.5 286 5 287 165 -14.3 0 -14 -14.6 02/02/2006 05:50:00 13.3 0.7 14.9 10.7 13.4 0.7 14.9 10.7 12.4 1.6 16.1 6.8 285 3 284 165 -14.5 0.1 -14.2 -14.6 02/02/2006 06:00:00 11.5 1.1 14.1 8.8 11.7 1.2 14.5 8.4 11.2 1.4 14.9 7.2 283 4 287 165 -14.4 0 -14.2 -14.6 02/02/2006 06:10:00 10.4 0.6 12.6 9.1 10.5 0.6 12.2 8.8 9 1.6 12.6 5.7 289 7 301 165 -14.2 0.1 -14 -14.6 02/02/2006 06:20:00 9.6 0.9 11.5 6.1 9.6 0.9 11.1 6.5 7.5 1.1 9.9 4.2 293 5 284 165 -13.9 0 -13.8 -14.2 02/02/2006 06:30:00 8 1.4 12.2 5.3 8 1.4 12.6 5.3 6.5 1.5 11.1 3.8 299 10 286 165 -13.9 0.1 -13.6 -14.2 02/02/2006 06:40:00 6.9 1.5 10.7 3.4 6.9 1.4 10.7 3.8 5.6 1.3 9.1 2.6 296 10 291 165 -14 0 -13.8 -14 02/02/2006 06:50:00 3.8 1 5.7 1.5 3.7 1 5.7 1.1 3.3 0.8 5.3 1.1 301 16 304 165 -14.1 0 -14 -14.4 02/02/2006 07:00:00 5.1 1.3 7.2 2.3 5.2 1.3 7.2 2.3 4.6 1.5 7.6 1.5 283 9 281 165 -14.2 0.1 -14 -14.6 02/02/2006 07:10:00 6.3 0.5 7.6 4.9 6.3 0.5 8 4.9 5.5 0.9 7.6 3.4 289 6 282 165 -14 0 -13.8 -14.2 02/02/2006 07:20:00 7.4 0.6 9.1 6.1 7.4 0.6 8.8 5.7 5.3 0.8 8 3.4 299 5 294 165 -14 0.1 -13.8 -14 02/02/2006 07:30:00 8.1 0.6 9.5 6.5 8.1 0.6 9.5 6.5 5.7 0.8 8 3.8 302 4 302 165 -14 0.1 -13.6 -14.2 02/02/2006 07:40:00 5.4 0.8 7.6 3.8 5.3 0.8 7.6 3.8 4.6 0.4 6.1 3.4 312 7 294 165 -13.7 0 -13.6 -13.8 02/02/2006 07:50:00 4.6 0.7 6.1 2.6 4.6 0.7 6.1 3 4 0.7 5.7 2.3 307 9 302 165 -13.8 0.1 -13.6 -14 02/02/2006 08:00:00 2.8 1 4.9 0.7 2.7 1.1 4.9 0.7 2.6 1 4.6 0.4 321 21 313 165 -13.8 0 -13.6 -14 02/02/2006 08:10:00 3.5 0.9 5.3 1.1 3.6 0.9 5.7 1.1 3.2 1 5.7 1.1 284 14 292 165 -13.8 0 -13.6 -14 02/02/2006 08:20:00 3.2 0.9 5.7 1.5 3.5 1 6.1 1.9 3.2 0.9 5.3 1.1 271 12 266 165 -13.9 0 -13.6 -14 02/02/2006 08:30:00 2 0.8 4.6 0.4 2 0.8 4.9 0.4 1.9 0.8 3.8 0.4 283 23 288 165 -13.9 0 -13.8 -14 02/02/2006 08:40:00 2.7 1 5.7 0.4 2.6 1.1 5.7 0.4 2.4 1 4.9 0.4 293 35 282 165 -13.8 0 -13.6 -14 02/02/2006 08:50:00 4.1 0.9 6.1 1.9 4.2 0.8 6.1 2.3 3.6 0.8 5.7 1.9 286 13 303 165 -13.9 0 -13.6 -14 02/02/2006 09:00:00 4.1 0.6 5.7 2.6 4 0.6 5.7 2.6 3.5 0.9 5.7 1.1 299 10 310 165 -14 0 -13.8 -14 02/02/2006 09:10:00 5.2 0.9 6.8 3 5.1 1 6.8 2.6 4.4 1 6.5 1.9 297 9 286 165 -13.6 0.1 -13.4 -14 02/02/2006 09:20:00 5 0.5 6.5 3.8 5 0.5 6.5 3.8 4 0.8 5.7 2.3 298 7 299 165 -13.6 0 -13.6 -13.8 02/02/2006 09:30:00 5.4 0.7 7.2 3.8 5.4 0.8 7.2 3.8 4.4 1 6.8 2.6 293 6 285 165 -13.6 0.1 -13.2 -13.8 02/02/2006 09:40:00 4.7 1 6.5 2.6 4.7 1 6.5 2.6 3.6 0.8 5.3 1.9 293 5 300 165 -13.2 0.1 -12.8 -13.6 02/02/2006 09:50:00 3.6 0.5 4.9 2.3 3.7 0.5 4.6 2.3 3.1 0.7 4.6 1.5 287 7 282 165 -12.9 0 -12.6 -13 02/02/2006 10:00:00 5 0.5 6.1 3.8 5 0.5 6.5 3.8 4.1 1 6.1 2.3 290 7 280 165 -12.8 0 -12.6 -13.2 02/02/2006 10:10:00 3.9 0.5 5.3 2.6 3.9 0.6 5.3 2.6 3.2 0.6 4.9 1.9 296 8 292 165 -12.6 0.1 -12.2 -13 02/02/2006 10:20:00 3 0.5 4.2 1.9 3 0.5 3.8 1.9 2.1 0.4 3 1.1 298 4 303 165 -12.1 0 -12 -12.2 02/02/2006 10:30:00 1.2 0.8 2.6 0.4 1.3 0.8 2.6 0.4 1 0.6 2.3 0.4 293 1 295 165 -11.3 0.7 -9.7 -12.2 02/02/2006 10:40:00 0.5 0.2 1.1 0.4 0.9 0.4 1.5 0.4 0.8 0.4 1.9 0.4 269 10 264 165 -9.2 0.4 -8.5 -10.2 02/02/2006 10:50:00 0.6 0.3 1.5 0.4 1.1 0.3 1.9 0.4 1.2 0.3 2.3 0.4 248 11 226 165 -10.6 0 -10.2 -10.8 02/02/2006 11:00:00 1.5 0.4 2.6 0.4 1.9 0.3 2.6 1.1 1.8 0.4 2.6 0.7 218 13 222 165 -10.3 0.1 -10.2 -10.6 02/02/2006 11:10:00 1.8 0.6 2.6 0.4 2 0.5 3 0.7 1.9 0.5 2.6 0.7 286 21 286 165 -11 0.4 -10.2 -11.6 02/02/2006 11:20:00 2.9 0.5 3.8 1.1 3 0.5 3.8 1.5 2.3 0.3 3 1.5 302 4 300 165 -11.5 0 -11.4 -11.8 02/02/2006 11:30:00 2.9 0.3 3.8 1.9 3 0.3 3.8 1.9 2.6 0.4 3.4 1.5 291 7 283 165 -11.7 0 -11.4 -11.8 02/02/2006 11:40:00 3.4 0.3 4.2 2.3 3.5 0.3 4.2 2.6 2.8 0.3 3.4 1.9 300 5 296 165 -11.4 0.2 -11 -11.8 02/02/2006 11:50:00 3.5 0.4 4.2 2.3 3.6 0.4 4.2 2.6 2.7 0.4 3.8 1.9 306 5 302 165 -11.4 0 -11 -11.4 02/02/2006 12:00:00 1.9 0.6 3.4 0.7 2.1 0.5 3.4 1.1 1.8 0.6 3.4 0.4 301 14 316 165 -10.2 0.4 -9.7 -11.2 02/02/2006 12:10:00 1.2 0.6 2.6 0.4 1.6 0.5 3 0.4 1.1 0.3 2.3 0.4 294 3 294 165 -10.1 0 -9.7 -10.2 02/02/2006 12:20:00 2.2 0.3 2.6 1.5 2.5 0.3 3 1.9 2.1 0.3 3 1.1 286 6 297 165 -10.5 0.1 -10.2 -10.8 02/02/2006 12:30:00 2 0.5 4.2 0.7 2.2 0.5 4.2 1.5 1.8 0.5 3.8 0.7 289 17 308 165 -10.4 0.2 -9.7 -11 02/02/2006 12:40:00 3 0.6 4.2 1.1 3.1 0.6 4.6 1.1 2.9 0.6 4.2 1.5 314 13 304 165 -9.2 0.2 -8.7 -9.7 02/02/2006 12:50:00 4.6 0.8 6.5 3 4.6 0.8 6.5 3 4.3 0.9 6.5 2.6 320 7 319 165 -9.4 0.3 -9.1 -10.2 02/02/2006 13:00:00 4.8 0.6 6.1 3.4 4.8 0.6 6.5 3.4 4.8 0.5 6.5 3.8 319 6 312 165 -10.4 0 -10.2 -10.6 02/02/2006 13:10:00 3.9 0.6 5.3 2.6 4 0.5 5.3 2.6 3.4 0.6 4.6 1.9 301 15 304 165 -10.3 0 -10 -10.6 02/02/2006 13:20:00 4.4 0.5 5.7 3 4.5 0.5 5.7 3.4 3.6 0.8 5.7 1.9 294 9 293 165 -10.7 0.1 -10.4 -11 02/02/2006 13:30:00 4.4 1.2 6.5 2.3 4.4 1.1 6.5 2.3 3.5 0.9 5.7 1.5 304 8 307 165 -10.2 0.1 -10 -10.6 02/02/2006 13:40:00 5.7 0.5 6.8 4.2 5.7 0.5 6.8 4.6 5.3 0.8 6.8 3.4 316 7 321 165 -10.2 0.1 -9.7 -10.6 02/02/2006 13:50:00 4.7 0.9 6.5 1.5 4.7 0.9 6.1 1.1 4.5 0.8 6.1 1.9 323 10 328 165 -9.6 0.2 -9.1 -10.2 02/02/2006 14:00:00 3.6 0.7 5.7 1.9 3.6 0.7 5.7 2.3 3.2 0.8 5.7 1.9 306 11 323 165 -9.8 0.3 -9.3 -10.4 02/02/2006 14:10:00 3.9 1 5.7 1.9 3.9 0.9 5.7 1.9 3.5 0.9 5.3 1.9 304 12 309 165 -10.4 0 -10.2 -10.6 02/02/2006 14:20:00 3.9 0.5 5.3 2.6 3.9 0.5 4.9 2.6 3.2 0.6 4.6 1.9 304 9 309 165 -10.3 0 -10.2 -10.4 02/02/2006 14:30:00 3.9 0.7 5.7 2.6 4 0.7 5.7 2.6 3.2 0.7 5.3 1.9 292 6 293 165 -10.2 0 -10.2 -10.4 02/02/2006 14:40:00 4.1 0.3 4.9 3.4 4.1 0.3 5.3 3.4 3.1 0.5 4.6 2.3 301 6 290 165 -10.2 0.1 -10 -10.6 02/02/2006 14:50:00 4.6 0.3 5.3 3.8 4.6 0.3 5.3 3.8 3.6 0.6 5.3 2.3 298 5 298 165 -10.7 0.1 -10.4 -11 02/02/2006 15:00:00 4.3 0.4 4.9 3.4 4.3 0.3 4.9 3.4 3.3 0.5 4.6 2.3 298 5 300 165 -10.5 0 -10.4 -10.8 02/02/2006 15:10:00 3.6 0.4 4.9 2.3 3.6 0.5 4.9 2.3 3 0.4 4.2 2.3 305 6 292 165 -10.6 0.2 -10.2 -11 02/02/2006 15:20:00 3.6 0.4 4.9 3 3.7 0.4 5.3 3 2.7 0.4 4.2 1.9 298 4 302 165 -10.6 0.2 -10.2 -10.8 02/02/2006 15:30:00 4 0.5 4.9 2.6 4.1 0.5 5.3 2.6 3.5 0.6 4.9 1.9 293 5 298 165 -10.8 0 -10.6 -11 02/02/2006 15:40:00 4.4 0.3 5.3 3.4 4.5 0.3 5.3 3.4 4.4 0.5 5.3 2.6 283 4 275 165 -10.9 0 -10.6 -11 02/02/2006 15:50:00 3.9 0.4 4.9 2.6 4 0.4 4.9 2.6 3.9 0.5 5.3 2.6 283 5 283 165 -10.9 0 -10.8 -11.2 02/02/2006 16:00:00 3.9 0.5 5.3 3 3.9 0.5 5.3 3 3.2 0.5 4.2 1.9 292 6 291 165 -11 0 -10.8 -11.2 02/02/2006 16:10:00 4.5 0.7 6.1 3 4.5 0.6 6.1 3 3.3 0.5 4.9 2.3 297 5 305 165 -11.2 0.1 -11 -11.4 02/02/2006 16:20:00 3.9 0.6 5.7 2.3 3.9 0.6 5.7 2.3 3 0.6 4.9 1.9 296 6 296 165 -11.5 0 -11.4 -11.6 02/02/2006 16:30:00 3.9 0.6 5.3 1.9 3.9 0.6 5.3 2.3 3 0.7 4.6 1.5 293 8 301 165 -11.3 0 -11.2 -11.4 02/02/2006 16:40:00 4.6 0.6 6.1 3 4.5 0.6 6.1 3 4.3 0.7 6.1 2.6 317 9 319 165 -11.1 0.1 -10.8 -11.4 02/02/2006 16:50:00 3.2 0.6 4.6 1.5 3.2 0.6 4.6 1.9 2.8 0.6 4.6 1.5 313 14 316 165 -11.2 0.1 -11 -11.4 02/02/2006 17:00:00 3.4 0.7 5.3 1.5 3.4 0.7 4.9 1.5 3.2 0.7 4.9 1.5 308 12 319 165 -11.6 0.1 -11.4 -11.8 02/02/2006 17:10:00 4.4 0.6 6.1 3 4.3 0.6 5.7 3 4 0.7 5.7 2.3 313 6 306 165 -12 0.2 -11.6 -12.4 02/02/2006 17:20:00 4.2 0.5 5.3 3 4.1 0.5 5.3 3 3.6 0.6 4.9 2.3 309 6 302 165 -12.6 0 -12.2 -12.6 02/02/2006 17:30:00 2.7 0.6 4.2 1.5 2.6 0.6 4.2 1.1 2 0.6 3.8 0.7 300 9 304 165 -12.4 0 -12.2 -12.6 02/02/2006 17:40:00 2.2 0.5 3.4 1.1 2.1 0.5 3.4 1.1 1.7 0.6 3.4 0.7 292 6 291 165 -12.4 0.1 -12.2 -12.6 02/02/2006 17:50:00 2.2 0.7 3.8 0.7 2.2 0.7 3.8 0.4 1.7 0.5 3.4 0.7 291 10 303 165 -12.4 0 -12.2 -12.4 02/02/2006 18:00:00 1.7 0.6 3 0.4 1.7 0.6 3 0.4 1.3 0.6 3 0.4 296 16 296 165 -12.4 0.1 -12.2 -12.6 02/02/2006 18:10:00 2.3 0.5 3.4 0.7 2.2 0.5 3.4 0.7 1.9 0.6 3 0.4 304 11 307 165 -12.4 0 -12.2 -12.6 02/02/2006 18:20:00 2 0.5 3 0.7 2 0.4 3 1.1 2 0.5 3 1.1 277 9 280 165 -12.1 0.1 -11.8 -12.4 02/02/2006 18:30:00 2 0.3 2.6 1.1 2.1 0.3 2.6 1.1 2.2 0.3 3 1.5 281 3 281 165 -11.8 0 -11.6 -12.2 02/02/2006 18:40:00 2.1 0.3 2.6 1.5 2.1 0.3 2.6 1.5 1.9 0.3 2.6 1.1 291 11 303 165 -11.8 0.1 -11.6 -12 02/02/2006 18:50:00 2.1 0.3 2.6 1.5 2.1 0.4 2.6 1.1 1.5 0.4 2.6 0.7 297 5 295 165 -12 0 -11.8 -12.2 02/02/2006 19:00:00 1.8 0.4 2.6 1.1 1.8 0.4 2.6 1.1 1.4 0.4 2.3 0.4 303 13 294 165 -11.9 0 -11.8 -12.2 02/02/2006 19:10:00 2.2 0.3 2.6 1.1 2 0.3 2.6 1.1 2.1 0.3 2.6 1.5 318 5 324 165 -12.2 0 -11.8 -12.2 02/02/2006 19:20:00 1.9 0.5 3 1.1 1.9 0.5 3 1.1 1.6 0.5 3 0.7 292 17 273 165 -11.9 0.1 -11.6 -12.4 02/02/2006 19:30:00 2.7 0.4 3.4 1.9 2.7 0.4 3.4 1.9 2.6 0.3 3.4 1.5 278 3 278 165 -11.6 0 -11.4 -11.8 02/02/2006 19:40:00 1.8 0.2 2.3 1.5 1.7 0.2 2.3 1.1 1.6 0.3 2.6 1.1 298 11 285 165 -11.8 0.1 -11.4 -11.8 02/02/2006 19:50:00 1.7 0.3 2.6 0.7 1.7 0.3 2.6 1.1 1.4 0.3 2.3 0.7 292 10 284 165 -11.7 0.1 -11.4 -12 02/02/2006 20:00:00 1.3 0.2 1.9 0.7 1.3 0.2 1.9 0.7 1.3 0.2 1.9 0.4 283 9 284 165 -11.3 0.1 -11.2 -11.8 02/02/2006 20:10:00 1.7 0.4 2.6 0.4 1.7 0.4 2.3 0.7 1.6 0.4 2.3 0.7 305 7 309 165 -11.4 0 -11.2 -11.6 02/02/2006 20:20:00 0.8 0.6 2.3 0.4 0.9 0.6 2.3 0.4 0.9 0.6 2.3 0.4 241 28 226 165 -11.3 0.1 -11.2 -11.6 02/02/2006 20:30:00 1.6 0.3 2.3 0.7 1.6 0.3 2.3 0.7 1.8 0.3 2.6 1.1 197 5 197 165 -11.4 0 -11.2 -11.4 02/02/2006 20:40:00 1 0.2 1.5 0.4 0.9 0.2 1.5 0.4 1.1 0.2 1.5 0.4 192 6 190 165 -11.4 0 -11.4 -11.6 02/02/2006 20:50:00 1 0.4 1.9 0.4 1 0.4 1.5 0.4 0.8 0.3 1.5 0.4 263 26 289 165 -11.3 0 -11.2 -11.6 02/02/2006 21:00:00 0.8 0.4 1.5 0.4 0.8 0.4 1.5 0.4 1 0.4 1.9 0.4 259 36 289 165 -11.4 0 -11.2 -11.6 02/02/2006 21:10:00 1.2 0.3 1.9 0.7 1.2 0.3 1.9 0.7 1.5 0.3 2.3 0.7 189 14 183 165 -11.5 0 -11.4 -11.6 02/02/2006 21:20:00 1.3 0.4 2.3 0.7 1.3 0.4 2.3 0.4 1.5 0.3 2.3 1.1 219 8 232 165 -11.4 0.1 -11 -11.6 02/02/2006 21:30:00 1.5 0.3 2.3 0.7 1.7 0.3 2.6 1.1 1.7 0.2 2.3 1.1 211 13 192 165 -10.9 0 -10.8 -11.2 02/02/2006 21:40:00 1.5 0.4 2.3 0.4 1.7 0.4 2.6 0.7 1.8 0.3 3 1.1 207 10 199 165 -11.1 0 -10.8 -11.4 02/02/2006 21:50:00 1.5 0.4 2.6 0.4 1.6 0.4 2.6 0.7 1.7 0.4 2.6 0.4 206 16 197 165 -11 0 -11 -11.2 02/02/2006 22:00:00 0.8 0.5 2.6 0.4 0.9 0.5 2.6 0.4 0.8 0.5 2.3 0.4 205 26 177 165 -10.9 0 -10.8 -11.4 02/02/2006 22:10:00 0.4 0.2 1.5 0.4 0.4 0.2 1.1 0.4 0.5 0.2 1.1 0.4 246 2 245 165 -10.7 0 -10.6 -11 02/02/2006 22:20:00 0.4 0.1 1.1 0.4 0.4 0.1 0.7 0.4 0.4 0.2 1.1 0.4 317 107 263 165 -10.7 0.1 -10.6 -11 02/02/2006 22:30:00 0.4 0.2 1.1 0.4 0.4 0.1 0.7 0.4 0.4 0.1 0.7 0.4 246 61 203 165 -11.1 0 -11 -11.4 02/02/2006 22:40:00 0.4 0.1 1.1 0.4 0.4 0.1 1.1 0.4 0.4 0.1 0.7 0.4 339 0 339 165 -11.5 0.1 -11.2 -11.8 02/02/2006 22:50:00 0.5 0.2 1.1 0.4 0.5 0.2 1.1 0.4 0.7 0.3 1.1 0.4 12 11 339 165 -11 0.1 -10.8 -11.4 02/02/2006 23:00:00 0.5 0.2 1.5 0.4 0.4 0.1 1.1 0.4 0.6 0.4 1.5 0.4 21 17 15 165 -11.3 0.1 -11 -11.4 02/02/2006 23:10:00 0.5 0.2 1.1 0.4 0.6 0.2 1.1 0.4 0.4 0.2 1.5 0.4 95 22 78 165 -11.1 0.1 -10.8 -11.4 02/02/2006 23:20:00 0.4 0.1 0.7 0.4 0.5 0.2 1.1 0.4 0.4 0.1 1.1 0.4 125 0 125 165 -11.9 0.2 -11.4 -12.2 02/02/2006 23:30:00 1.5 0.4 2.3 0.4 1.6 0.4 2.3 0.4 1.4 0.4 1.9 0.4 125 0 125 165 -11.5 0.2 -11.4 -12.2 02/02/2006 23:40:00 1.7 0.2 2.3 1.1 1.8 0.2 2.3 1.5 1.8 0.2 2.3 1.5 128 2 125 165 -11.3 0 -11 -11.4 02/02/2006 23:50:00 1.4 0.3 1.9 1.1 1.6 0.2 2.3 1.1 1.6 0.2 2.3 1.1 140 2 130 165 -11 0 -11 -11.2 02/03/2006 00:00:00 1.3 0.4 1.9 0.4 1.4 0.4 2.3 0.4 1.4 0.4 2.3 0.7 138 2 135 165 -11.1 0.1 -11 -11.4 02/03/2006 00:10:00 1.3 0.2 1.9 0.7 1.4 0.2 1.9 0.7 1.4 0.3 1.9 0.7 141 6 136 165 -11.1 0 -11 -11.4 02/03/2006 00:20:00 1.2 0.2 1.5 0.7 1.2 0.2 1.5 0.7 1.2 0.2 1.5 0.7 155 0 155 165 -11.1 0 -11 -11.2 02/03/2006 00:30:00 0.8 0.4 1.5 0.4 0.8 0.4 1.5 0.4 0.9 0.5 1.9 0.4 157 2 156 165 -11.3 0.1 -11 -11.4 02/03/2006 00:40:00 0.6 0.3 1.5 0.4 0.5 0.3 1.5 0.4 0.4 0.2 1.1 0.4 170 13 193 165 -11.3 0 -11.2 -11.4 02/03/2006 00:50:00 0.9 0.3 1.5 0.4 0.8 0.3 1.5 0.4 0.9 0.3 1.5 0.4 193 0 193 165 -11.2 0.2 -10.8 -11.4 02/03/2006 01:00:00 1.2 0.3 1.9 0.7 1.3 0.3 1.9 0.7 1.2 0.3 1.9 0.4 191 1 193 165 -10.8 0.1 -10.6 -11 02/03/2006 01:10:00 1.7 0.4 2.6 1.1 1.8 0.4 2.3 1.1 1.7 0.4 2.3 1.1 183 6 173 165 -10.7 0.1 -10.4 -11 02/03/2006 01:20:00 1.8 0.3 2.6 1.5 1.9 0.3 2.6 1.5 2 0.3 2.6 1.5 179 1 181 165 -10.5 0 -10.4 -10.8 02/03/2006 01:30:00 2.4 0.3 3 1.5 2.5 0.3 3 1.5 2.5 0.3 3 1.5 186 5 186 165 -10.4 0 -10.2 -10.6 02/03/2006 01:40:00 1.7 0.2 2.3 1.1 1.7 0.2 2.3 1.1 1.5 0.2 1.9 0.7 179 7 176 165 -10.4 0 -10.2 -10.6 02/03/2006 01:50:00 1.9 0.3 2.3 1.1 1.9 0.3 2.3 1.1 1.6 0.3 2.3 0.7 192 3 198 165 -10.5 0 -10.2 -10.6 02/03/2006 02:00:00 0.8 0.3 1.5 0.4 0.7 0.3 1.5 0.4 0.8 0.2 1.5 0.4 189 0 190 165 -10.4 0 -10.2 -10.6 02/03/2006 02:10:00 0.8 0.5 2.3 0.4 0.7 0.4 1.5 0.4 0.9 0.7 2.3 0.4 120 82 358 165 -10.6 0.1 -10.2 -10.8 02/03/2006 02:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 162 0 165 165 -10.5 0 -10.4 -10.8 02/03/2006 02:30:00 1.7 0.7 3 0.4 1.7 0.7 3 0.4 1.9 0.8 3 0.4 170 6 181 165 -10.4 0.1 -10.2 -10.8 02/03/2006 02:40:00 2.2 0.4 3 1.5 2.2 0.4 3 1.5 2.3 0.3 3.4 1.9 170 8 165 165 -10.6 0.1 -10.2 -10.8 02/03/2006 02:50:00 3 0.4 3.8 2.3 3 0.3 3.8 2.3 2.9 0.4 3.8 2.3 172 6 176 165 -10.5 0.2 -10.2 -10.8 02/03/2006 03:00:00 2.3 0.3 3 1.5 2.3 0.3 3 1.9 2.3 0.2 2.6 1.9 172 11 177 165 -10.7 0.1 -10.2 -11 02/03/2006 03:10:00 2.7 0.3 3.4 1.9 2.7 0.3 3 2.3 2.6 0.2 3 2.3 180 2 178 165 -10.2 0 -10 -10.6 02/03/2006 03:20:00 2.9 0.6 3.8 1.9 2.9 0.5 3.8 1.9 2.9 0.4 3.8 2.3 185 4 181 165 -10.2 0 -10.2 -10.4 02/03/2006 03:30:00 3 0.3 3.8 2.6 3 0.2 3.4 2.6 3 0.3 3.8 2.3 181 3 178 165 -10.2 0 -10.2 -10.4 02/03/2006 03:40:00 2.7 0.2 3 2.3 2.7 0.2 3 2.3 2.8 0.3 3.4 2.3 181 1 182 165 -10.2 0 -10 -10.4 02/03/2006 03:50:00 2.8 0.4 3.8 1.9 2.7 0.4 3.8 1.9 2.7 0.4 3.8 1.9 180 2 180 165 -10.2 0 -10 -10.2 02/03/2006 04:00:00 3.1 0.2 3.4 2.6 3.1 0.2 3.4 2.6 3.1 0.3 3.4 2.3 185 4 183 165 -10 0.1 -9.7 -10.2 02/03/2006 04:10:00 2.4 0.2 3 1.9 2.4 0.2 3 1.9 2.4 0.2 3 1.9 181 1 181 165 -9.7 0 -9.7 -10 02/03/2006 04:20:00 2.4 0.4 3 1.5 2.3 0.3 3 1.5 2.2 0.3 2.6 1.5 183 3 180 165 -9.7 0.1 -9.5 -10.2 02/03/2006 04:30:00 3 0.3 3.4 2.3 2.9 0.3 3.4 2.3 2.9 0.3 3.4 2.3 175 8 181 165 -9.6 0 -9.3 -9.7 02/03/2006 04:40:00 3.7 0.4 4.6 2.6 3.6 0.4 4.2 2.6 3.3 0.4 4.2 2.6 182 6 189 165 -9.5 0 -9.3 -9.7 02/03/2006 04:50:00 3.4 0.2 3.8 2.6 3.3 0.2 3.8 2.6 3.1 0.3 3.8 2.3 191 6 187 165 -9.3 0.1 -8.9 -9.7 02/03/2006 05:00:00 3.1 0.3 3.8 1.9 3 0.3 3.8 1.9 3 0.3 3.4 2.3 176 10 180 165 -9.3 0 -8.9 -9.5 02/03/2006 05:10:00 3.5 0.3 4.2 3 3.5 0.2 4.2 3 3.3 0.2 3.8 2.6 187 4 183 165 -9.1 0 -8.9 -9.5 02/03/2006 05:20:00 3.6 0.3 4.2 2.6 3.5 0.3 4.2 3 3.4 0.3 4.2 2.6 181 2 183 165 -9.1 0.1 -8.9 -9.3 02/03/2006 05:30:00 3.1 0.3 4.2 2.3 3.1 0.3 3.8 2.3 2.8 0.4 3.8 1.9 189 8 186 165 -9.1 0 -8.9 -9.3 02/03/2006 05:40:00 2.7 0.4 3.8 1.9 2.8 0.4 3.8 1.9 2.6 0.4 3.4 1.9 199 6 203 165 -9 0 -8.7 -9.3 02/03/2006 05:50:00 2.5 0.4 3.4 1.1 2.5 0.4 3.4 1.1 2.2 0.5 3 0.7 189 8 187 165 -9.1 0.1 -8.9 -9.3 02/03/2006 06:00:00 2.8 0.4 3.8 1.5 2.8 0.4 3.8 1.9 2.6 0.4 3.4 1.5 186 7 189 165 -8.9 0 -8.7 -9.1 02/03/2006 06:10:00 3 0.5 4.2 1.1 3 0.5 4.2 1.1 2.8 0.5 3.8 1.5 190 8 180 165 -8.8 0 -8.5 -9.1 02/03/2006 06:20:00 2.2 0.8 3.8 0.4 2.2 0.9 3.8 0.4 2 0.8 3.8 0.4 222 17 202 165 -8.7 0.1 -8.5 -8.9 02/03/2006 06:30:00 1.7 0.8 3 0.4 1.7 0.8 3 0.4 1.4 0.8 2.6 0.4 215 21 217 165 -8.5 0 -8.5 -8.7 02/03/2006 06:40:00 1 0.5 2.3 0.4 0.9 0.5 2.3 0.4 0.7 0.5 2.3 0.4 225 15 211 165 -8.4 0 -8.3 -8.5 02/03/2006 06:50:00 1.7 0.9 3.8 0.4 1.6 0.9 3.8 0.4 1.5 1 3.8 0.4 221 23 214 165 -8.3 0.2 -8.1 -8.5 02/03/2006 07:00:00 1.1 0.5 2.6 0.4 1.1 0.5 2.6 0.4 1.1 0.5 2.3 0.4 175 15 188 165 -8 0 -7.9 -8.3 02/03/2006 07:10:00 1.7 0.7 4.2 0.4 1.6 0.8 3.8 0.4 1.5 0.7 3.4 0.4 191 12 188 165 -8.4 0 -8.3 -8.5 02/03/2006 07:20:00 2.8 0.6 4.6 1.1 2.8 0.5 4.6 1.5 2.5 0.7 4.6 1.1 180 9 186 165 -8.1 0.1 -7.6 -8.5 02/03/2006 07:30:00 2.3 0.6 3.4 0.7 2.3 0.6 3.4 0.7 2.1 0.6 3.4 0.7 193 8 184 165 -7.6 0.1 -7.4 -8.1 02/03/2006 07:40:00 2.1 0.3 2.6 1.1 2.2 0.3 3 1.5 2.1 0.3 2.6 1.1 184 4 196 165 -7.9 0.1 -7.6 -8.1 02/03/2006 07:50:00 2.1 0.5 3.4 1.5 2.2 0.4 3.4 1.5 2.1 0.4 3 1.1 177 6 176 165 -7.4 0 -7.2 -7.6 02/03/2006 08:00:00 3.2 0.2 3.4 2.6 3.2 0.2 3.4 2.6 3.2 0.2 3.4 2.6 176 2 177 165 -7.2 0 -7 -7.4 02/03/2006 08:10:00 3.6 0.4 4.2 2.6 3.4 0.3 3.8 2.6 3.4 0.4 4.2 2.3 171 3 174 165 -7.4 0.1 -7.2 -7.4 02/03/2006 08:20:00 3.4 0.2 3.8 2.6 3.3 0.2 3.8 2.6 3.3 0.3 3.8 2.6 170 3 171 165 -7.5 0 -7.4 -7.6 02/03/2006 08:30:00 3.8 0.3 4.2 3 3.7 0.3 4.2 3 3.6 0.4 4.2 2.6 171 4 167 165 -7.6 0 -7.4 -7.6 02/03/2006 08:40:00 3.4 0.4 4.2 2.6 3.3 0.4 4.2 2.6 3.4 0.3 4.2 2.6 178 1 174 165 -7.5 0.1 -7.2 -7.6 02/03/2006 08:50:00 3.7 0.3 4.2 2.6 3.6 0.3 4.2 2.6 3.5 0.3 4.2 3 172 3 172 165 -7.1 0 -6.8 -7.4 02/03/2006 09:00:00 4.1 0.4 4.9 3.4 4 0.4 4.9 3 3.9 0.3 4.6 3 172 4 169 165 -7.1 0.1 -6.8 -7.2 02/03/2006 09:10:00 4.7 0.7 5.7 3.4 4.5 0.6 5.7 3.4 4.3 0.6 5.7 3.4 173 5 176 165 -6.7 0 -6.6 -7 02/03/2006 09:20:00 5.7 0.3 6.1 4.6 5.4 0.2 6.1 4.6 5.3 0.4 6.1 4.6 177 2 175 165 -6.4 0.1 -6.1 -6.6 02/03/2006 09:30:00 5.7 0.3 6.1 4.9 5.5 0.2 6.1 4.9 5.5 0.3 6.1 4.9 177 1 177 165 -6 0.2 -5.7 -6.4 02/03/2006 09:40:00 5.1 0.2 5.7 4.9 5 0.2 5.3 4.6 4.8 0.2 5.3 4.2 176 2 179 165 -5.5 0.1 -5.3 -5.9 02/03/2006 09:50:00 5.5 0.2 6.1 4.9 5.4 0.2 6.1 4.9 5.3 0.4 6.1 4.6 181 2 181 165 -5.2 0 -4.8 -5.5 02/03/2006 10:00:00 6.5 0.5 7.6 5.7 6.3 0.5 7.2 5.3 6.4 0.6 7.6 5.3 176 2 178 165 -4.7 0.1 -4.4 -5 02/03/2006 10:10:00 6.4 0.5 7.2 4.9 6.2 0.4 7.2 4.9 6.4 0.4 7.2 5.3 178 5 180 165 -4.4 0 -4.2 -4.6 02/03/2006 10:20:00 5.4 0.4 6.8 4.6 5.4 0.4 6.5 4.6 5.3 0.4 6.5 4.2 184 5 183 165 -4.5 0 -4.4 -4.6 02/03/2006 10:30:00 5.9 0.6 7.2 4.6 5.8 0.5 6.8 4.6 5.9 0.7 7.2 3.4 182 4 179 165 -4.2 0.1 -3.9 -4.4 02/03/2006 10:40:00 6 0.6 7.2 4.2 5.8 0.5 6.8 4.2 6 0.5 7.2 4.6 176 5 179 165 -3.7 0.1 -3.3 -4.2 02/03/2006 10:50:00 6.8 0.4 8 5.7 6.6 0.4 7.6 5.3 6.8 0.4 8 5.3 173 5 172 165 -3.3 0 -3 -3.5 02/03/2006 11:00:00 7.1 0.7 8.4 4.9 6.8 0.6 8 4.9 7 0.6 8.8 4.9 172 7 172 165 -3.3 0 -3 -3.5 02/03/2006 11:10:00 6.6 0.9 8.4 4.6 6.5 0.8 8 4.2 6.7 0.9 8.4 4.2 172 13 167 165 -3.4 0 -3.3 -3.5 02/03/2006 11:20:00 5.9 1.1 8 3.4 5.7 1 8 3.4 6 1 8 3 169 11 163 165 -3.5 0 -3.3 -3.5 02/03/2006 11:30:00 5.4 0.6 6.8 3.4 5.3 0.5 6.5 3.8 5.5 0.6 6.8 3.8 172 10 180 165 -3.3 0 -3.3 -3.5 02/03/2006 11:40:00 5.3 0.7 6.5 3 5.3 0.6 6.5 3 5.4 0.6 6.8 3.8 170 11 157 165 -3.3 0 -3 -3.5 02/03/2006 11:50:00 4.9 0.4 6.1 3.8 4.9 0.4 6.1 3.8 4.9 0.4 5.7 3.8 167 5 165 165 -3 0 -2.8 -3.3 02/03/2006 12:00:00 5.7 0.5 6.8 4.2 5.6 0.4 6.8 4.6 5.8 0.4 6.8 4.6 170 6 167 165 -3.1 0 -2.8 -3.3 02/03/2006 12:10:00 6 0.5 8 4.6 5.9 0.5 7.6 4.9 6.1 0.5 7.6 4.6 169 6 163 165 -3 0 -2.8 -3.3 02/03/2006 12:20:00 5.2 0.5 6.8 3.8 5.2 0.5 6.5 3.8 5.4 0.5 6.8 3.8 168 11 161 165 -2.8 0 -2.6 -2.8 02/03/2006 12:30:00 4.7 0.5 6.1 3 4.7 0.5 5.7 3.4 4.9 0.5 6.5 3.4 167 9 165 165 -2.9 0 -2.6 -3 02/03/2006 12:40:00 5.4 0.5 6.5 4.2 5.2 0.4 6.1 4.2 5.5 0.4 6.5 4.2 168 8 164 165 -3.3 0 -3 -3.5 02/03/2006 12:50:00 5.2 0.6 6.5 3.8 5.1 0.5 6.1 4.2 5.3 0.4 6.5 4.2 172 5 165 165 -3.3 0 -3.3 -3.5 02/03/2006 13:00:00 5.8 0.6 7.2 4.2 5.7 0.5 6.8 4.2 6 0.6 7.2 4.6 171 5 174 165 -3.2 0.1 -2.8 -3.5 02/03/2006 13:10:00 5.3 0.7 6.8 3.4 5.3 0.6 6.5 3.4 5.5 0.7 6.8 4.2 169 5 165 165 -3.2 0.1 -2.8 -3.5 02/03/2006 13:20:00 5.9 0.6 7.2 4.6 5.8 0.5 6.8 4.2 5.9 0.6 7.2 4.6 165 6 164 165 -3.1 0 -2.8 -3.3 02/03/2006 13:30:00 5.7 0.6 7.2 4.2 5.6 0.5 6.8 4.6 5.9 0.5 8 4.6 164 9 165 165 -3.2 0.1 -2.8 -3.5 02/03/2006 13:40:00 6.6 0.7 8.8 4.9 6.4 0.6 8.4 4.9 6.7 0.5 8 5.3 166 13 176 165 -3.7 0 -3.5 -3.9 02/03/2006 13:50:00 6.6 0.7 8.4 4.9 6.4 0.6 8 4.6 6.7 0.6 8.4 5.3 168 6 165 165 -3.8 0 -3.5 -3.9 02/03/2006 14:00:00 6.8 0.7 8.4 4.9 6.7 0.6 8 5.3 6.9 0.6 8.8 5.7 164 6 160 165 -3.7 0 -3.5 -3.9 02/03/2006 14:10:00 6.8 0.5 8 5.7 6.7 0.4 8 5.7 6.8 0.4 7.6 5.7 161 3 164 165 -3.5 0.2 -3 -3.9 02/03/2006 14:20:00 6.4 0.6 8 4.6 6.3 0.6 8 4.6 6.4 0.6 8 3.8 163 5 165 165 -3.3 0 -3 -3.5 02/03/2006 14:30:00 7.2 0.6 8.8 5.3 7 0.6 8.4 4.9 7.2 0.6 8.8 5.3 169 5 175 165 -3.3 0 -3.3 -3.5 02/03/2006 14:40:00 6.8 0.7 8.8 4.2 6.6 0.7 8 4.6 6.9 0.6 8.8 4.6 169 13 282 165 -3.2 0 -3 -3.5 02/03/2006 14:50:00 5.5 0.6 7.2 4.2 5.4 0.5 7.2 4.2 5.7 0.5 7.2 4.6 162 6 162 165 -3.3 0 -3 -3.5 02/03/2006 15:00:00 4.8 0.9 6.8 2.6 4.8 0.8 6.8 2.6 5 0.8 7.2 3 159 8 162 165 -3.1 0.1 -2.6 -3.3 02/03/2006 15:10:00 5.1 0.5 6.1 3 5 0.5 6.1 3.4 5.2 0.5 6.8 3.8 162 6 149 165 -3 0.1 -2.8 -3.3 02/03/2006 15:20:00 5.2 0.6 6.5 3.8 5.1 0.5 6.5 3.8 5.3 0.5 6.8 4.2 160 4 164 165 -2.9 0 -2.6 -3 02/03/2006 15:30:00 5.4 0.6 7.2 3.8 5.4 0.5 7.2 4.2 5.5 0.5 7.2 4.2 168 8 167 165 -2.8 0.1 -2.6 -3 02/03/2006 15:40:00 6.1 1 8.8 3.8 6 0.9 8.4 4.2 6.1 0.8 8.4 4.2 168 6 165 165 -3.1 0 -2.8 -3.5 02/03/2006 15:50:00 6.3 0.9 8.8 4.2 6.2 0.8 8.8 4.2 6.2 0.8 8.4 4.6 160 11 161 165 -3.4 0 -3.3 -3.5 02/03/2006 16:00:00 7.4 0.9 10.7 4.9 7.3 0.9 11.1 4.9 7.4 0.8 9.1 5.3 155 15 156 165 -3.2 0.2 -2.8 -3.5 02/03/2006 16:10:00 8.5 1.2 12.6 5.7 8.4 1.2 11.8 4.9 8.5 1.1 12.2 5.7 155 12 165 165 -2.8 0 -2.6 -3 02/03/2006 16:20:00 12.7 1.3 16.4 9.5 12.7 1.3 16.4 9.5 12.8 1.4 15.6 9.5 156 6 157 165 -2.2 0.3 -1.9 -2.8 02/03/2006 16:30:00 13.7 1 16.4 11.1 13.6 1 16.4 10.7 14 1.2 16.4 9.9 156 5 148 165 -2.1 0 -1.9 -2.1 02/03/2006 16:40:00 13.4 1.1 15.6 10.3 13.3 1.1 15.6 10.7 13.5 1.2 16.4 10.3 157 10 155 165 -2.1 0 -1.9 -2.1 02/03/2006 16:50:00 13.3 1 15.6 10.3 13.2 1 15.3 10.3 13.5 1.1 16.8 10.3 160 17 166 165 -2 0 -1.9 -2.1 02/03/2006 17:00:00 12.7 1 15.6 10.3 12.6 1 16.1 10.3 12.9 1.1 16.1 9.5 157 12 145 165 -2.1 0 -1.9 -2.1 02/03/2006 17:10:00 13.1 1 16.1 10.3 13 1 16.1 9.9 13.3 1.1 16.8 10.3 156 7 148 165 -2.1 0 -1.9 -2.1 02/03/2006 17:20:00 13.7 1 15.6 9.9 13.6 1 16.1 10.3 13.9 1.1 16.1 9.1 157 15 164 165 -2.1 0 -1.9 -2.1 02/03/2006 17:30:00 14 1.2 16.8 11.1 14 1.2 16.8 11.1 14.2 1.2 16.8 10.7 153 5 148 165 -2.1 0 -1.9 -2.1 02/03/2006 17:40:00 12.5 1 14.9 9.1 12.4 1 14.9 8.4 12.6 1.2 14.9 9.1 155 5 154 165 -2 0 -1.9 -2.1 02/03/2006 17:50:00 11.2 1 13.7 8.4 11.2 1 13.7 7.6 11.1 1 14.1 8 156 7 153 165 -2.1 0 -1.9 -2.1 02/03/2006 18:00:00 13 1 14.9 10.7 13 1 15.3 10.3 13 1.2 15.6 8.8 153 5 154 165 -2 0 -1.9 -2.1 02/03/2006 18:10:00 13.5 1 15.6 10.7 13.6 0.9 15.6 11.5 13.4 1.2 16.4 9.9 149 5 153 165 -2 0 -1.9 -2.1 02/03/2006 18:20:00 12.7 0.8 14.5 9.5 12.7 0.8 14.5 9.9 12.8 1 15.3 8.8 154 6 156 165 -2 0 -1.9 -2.1 02/03/2006 18:30:00 13.1 0.8 15.3 11.1 13.1 0.8 15.3 11.1 13.2 0.9 15.3 9.9 151 5 148 165 -2 0 -1.9 -2.1 02/03/2006 18:40:00 12.5 1.1 14.9 9.1 12.5 1.1 14.9 9.1 12.7 1.2 16.1 9.1 156 11 153 165 -2 0 -1.9 -2.1 02/03/2006 18:50:00 12.6 0.8 14.9 8.8 12.6 0.8 14.5 8.8 12.6 1 14.9 9.1 155 5 161 165 -2 0 -1.9 -2.1 02/03/2006 19:00:00 13.1 0.9 15.6 10.7 13.1 0.9 16.1 10.7 13.4 1 16.1 9.5 153 5 142 165 -2 0 -1.9 -2.1 02/03/2006 19:10:00 12.5 1 14.9 9.5 12.5 0.9 14.9 9.5 12.7 1.2 15.3 8.8 157 11 152 165 -2 0 -1.7 -2.1 02/03/2006 19:20:00 14 0.8 16.1 11.5 13.9 0.8 16.1 11.5 14.2 0.8 17.2 12.2 155 5 158 165 -2 0 -1.9 -2.1 02/03/2006 19:30:00 12.8 0.9 14.5 9.9 12.9 0.9 14.9 9.9 13 1.1 14.9 9.5 152 5 147 165 -2 0 -1.9 -2.1 02/03/2006 19:40:00 13 1 16.1 9.9 13 1 16.1 9.5 13.1 1.2 16.1 9.1 153 5 145 165 -2 0 -1.9 -2.1 02/03/2006 19:50:00 13 1 15.3 9.5 13 1 15.3 9.9 13.1 1.2 15.6 9.1 153 5 150 165 -2 0 -1.9 -1.9 02/03/2006 20:00:00 12.7 0.9 15.6 10.3 12.7 0.9 15.6 10.7 12.8 1.2 16.1 8.8 153 6 160 165 -2 0 -1.9 -2.1 02/03/2006 20:10:00 12.6 1 15.6 9.9 12.6 0.9 15.3 9.9 12.7 1 15.3 9.5 152 4 150 165 -2.1 0 -1.9 -2.1 02/03/2006 20:20:00 12.1 0.8 13.7 9.9 12.2 0.8 14.1 9.9 12.2 0.9 14.5 10.3 150 6 156 165 -2 0 -1.9 -2.1 02/03/2006 20:30:00 11.9 0.7 13.7 9.1 12 0.7 13.7 9.5 11.9 0.9 13.7 9.1 149 6 154 165 -2 0 -1.9 -2.1 02/03/2006 20:40:00 12.7 0.8 14.5 10.3 12.8 0.8 14.1 10.3 12.8 0.8 14.9 9.9 150 4 159 165 -2 0 -1.9 -2.1 02/03/2006 20:50:00 12.5 1 14.5 8.4 12.6 1 14.5 9.1 12.3 1.2 14.9 8.4 150 5 156 165 -2 0 -1.9 -1.9 02/03/2006 21:00:00 11.6 1 14.1 8.8 11.6 1 13.7 9.1 11.6 1.2 14.1 7.6 153 5 153 165 -1.8 0 -1.4 -1.9 02/03/2006 21:10:00 12.9 0.9 15.3 10.7 12.9 0.8 15.3 10.7 13.1 1 15.3 9.9 154 4 151 165 -1.7 0 -1.4 -1.9 02/03/2006 21:20:00 13.1 0.8 16.4 10.7 13.1 0.8 16.1 10.7 13.3 1 16.4 10.3 154 7 154 165 -1.7 0 -1.4 -1.9 02/03/2006 21:30:00 12.5 1 15.6 9.5 12.6 0.9 15.6 10.3 12.5 1.1 15.6 9.5 154 5 157 165 -1.7 0 -1.4 -1.9 02/03/2006 21:40:00 13.6 0.9 16.1 9.9 13.7 0.9 16.1 9.9 13.7 1.1 16.1 9.9 151 5 145 165 -1.7 0 -1.4 -1.9 02/03/2006 21:50:00 13.3 0.8 15.3 11.1 13.3 0.7 15.3 11.5 13.2 0.9 15.6 11.1 148 5 149 165 -1.6 0 -1.4 -1.7 02/03/2006 22:00:00 13.9 0.9 16.4 11.5 14 1 16.4 11.5 13.9 1.1 16.4 11.1 150 5 157 165 -1.6 0 -1.4 -1.7 02/03/2006 22:10:00 11.2 1.1 14.1 7.6 11.1 1 13.7 8.4 11.2 1.2 14.5 7.6 156 7 165 165 -1.6 0 -1.4 -1.7 02/03/2006 22:20:00 12.8 1.1 15.3 10.3 12.8 1.1 15.3 10.3 13 1.1 15.6 10.7 153 4 153 165 -1.7 0 -1.4 -1.7 02/03/2006 22:30:00 14.5 1.1 17.2 11.5 14.6 1 17.2 11.8 14.5 1.3 17.9 10.7 149 5 151 165 -1.6 0 -1.4 -1.7 02/03/2006 22:40:00 14.4 1 16.8 11.8 14.4 1 16.8 11.8 14.4 1.1 16.8 11.1 147 5 159 165 -1.6 0 -1.4 -1.7 02/03/2006 22:50:00 16.1 1.8 19.1 11.8 16.1 1.8 19.1 11.8 16.1 2 19.5 11.5 149 5 145 165 -1.5 0 -1.4 -1.7 02/03/2006 23:00:00 17 0.8 19.9 14.5 17 0.7 19.5 14.5 17.1 1 19.9 14.1 150 4 150 165 -1.7 0 -1.4 -1.7 02/03/2006 23:10:00 17 1.2 19.9 13.3 16.9 1.1 19.9 14.1 17.2 1.3 20.2 12.6 153 4 157 165 -1.7 0 -1.4 -1.9 02/03/2006 23:20:00 15.4 1.1 17.9 11.1 15.5 1.1 17.6 11.1 15.5 1.2 17.9 11.5 148 5 148 165 -1.7 0 -1.4 -1.9 02/03/2006 23:30:00 16.4 1.5 19.9 12.2 16.4 1.5 19.5 12.2 16.5 1.7 20.2 11.8 152 5 153 165 -1.8 0.3 -1.4 -2.1 02/03/2006 23:40:00 15.2 1.7 18.7 8.8 15 1.6 18.7 8.8 15.2 2 19.1 8.8 160 10 153 165 -2 0 -1.7 -2.1 02/03/2006 23:50:00 16 1.5 19.1 11.5 16.1 1.5 19.1 11.5 16 1.7 19.9 10.7 148 5 151 165 -1.7 0 -1.4 -1.9 02/04/2006 00:00:00 16.9 1.1 19.5 13.7 16.9 1.1 19.5 13.7 17 1.2 19.9 13.3 148 4 150 165 -1.7 0 -1.4 -1.7 02/04/2006 00:10:00 16.3 1 18.7 13.7 16.4 1 19.1 13.3 16.4 1.2 19.5 12.6 147 5 148 165 -1.7 0 -1.4 -1.7 02/04/2006 00:20:00 15.6 1.2 18.3 11.8 15.8 1.2 18.7 12.2 15.5 1.3 19.1 11.8 141 7 153 165 -1.7 0 -1.4 -1.9 02/04/2006 00:30:00 15.9 1.3 20.2 12.6 16 1.3 20.2 13 16 1.5 20.2 11.5 144 6 139 165 -1.7 0 -1.7 -1.9 02/04/2006 00:40:00 15.6 1.1 17.9 12.6 15.6 1.1 17.9 12.2 15.8 1.3 18.7 11.8 147 4 147 165 -1.7 0 -1.4 -1.9 02/04/2006 00:50:00 15.4 1 18.3 12.2 15.4 1 18.3 13 15.5 1.1 18.3 12.6 146 4 140 165 -1.7 0 -1.4 -1.7 02/04/2006 01:00:00 15.7 0.9 17.9 13.3 15.8 0.9 17.9 13.7 15.9 1 17.9 12.2 147 5 145 165 -1.7 0 -1.4 -1.7 02/04/2006 01:10:00 15.2 1 17.2 12.2 15.2 1 17.2 13 15.4 1.1 17.6 11.1 152 5 151 165 -1.6 0 -1.4 -1.7 02/04/2006 01:20:00 14.5 1.1 17.2 11.5 14.6 1 17.2 11.5 14.5 1.3 17.6 10.3 148 5 156 165 -1.6 0 -1.4 -1.7 02/04/2006 01:30:00 13.7 1 16.1 11.1 13.8 1 16.4 11.1 13.9 1.2 16.8 11.1 148 5 154 165 -1.7 0 -1.4 -1.9 02/04/2006 01:40:00 15 0.9 17.2 11.8 15 0.8 17.2 12.2 15.2 1 17.6 12.2 150 4 148 165 -1.6 0 -1.4 -1.7 02/04/2006 01:50:00 14.9 1.1 16.8 11.5 14.9 1 16.8 12.2 14.9 1.2 17.6 11.8 150 4 154 165 -1.6 0 -1.4 -1.7 02/04/2006 02:00:00 15 1.1 18.7 11.1 15 1 18.7 11.1 15.1 1.3 18.7 10.7 150 4 145 165 -1.6 0 -1.4 -1.7 02/04/2006 02:10:00 15.1 0.9 17.2 12.2 15.2 1 17.6 12.6 15.1 1.1 17.6 11.5 147 5 143 165 -1.6 0 -1.4 -1.7 02/04/2006 02:20:00 15.5 1.1 19.5 12.6 15.5 1.1 19.1 13 15.5 1.4 19.5 11.1 147 5 152 165 -1.6 0 -1.4 -1.7 02/04/2006 02:30:00 15.3 1 17.6 11.8 15.3 1 17.6 12.2 15.4 1.1 17.6 12.2 151 4 158 165 -1.6 0 -1.4 -1.7 02/04/2006 02:40:00 15 0.9 16.8 12.2 15.1 0.9 16.8 12.2 15.1 1 17.2 12.2 147 5 154 165 -1.6 0 -1.4 -1.7 02/04/2006 02:50:00 15.8 0.8 17.6 13 15.9 0.9 18.3 13 15.7 1.1 17.9 12.2 147 4 140 165 -1.6 0 -1.4 -1.7 02/04/2006 03:00:00 15.3 1.1 18.3 12.6 15.4 1.1 18.3 12.6 15.4 1.4 18.3 11.5 147 5 153 165 -1.5 0 -1.4 -1.7 02/04/2006 03:10:00 14.9 1 17.2 11.8 15 1 17.2 11.8 14.8 1.2 17.2 11.1 145 5 147 165 -1.4 0 -1.4 -1.4 02/04/2006 03:20:00 15.5 1.2 18.7 12.6 15.7 1.2 18.7 12.6 15.5 1.4 18.7 10.7 143 5 143 165 -1.4 0 -1.4 -1.4 02/04/2006 03:30:00 16.1 1.3 18.7 13 16.2 1.3 18.7 13 16.1 1.5 19.5 11.8 144 6 139 165 -1.4 0 -1.2 -1.4 02/04/2006 03:40:00 16 1.2 19.1 12.6 16.1 1.2 18.7 12.6 16.2 1.4 19.5 12.6 144 6 146 165 -1.4 0 -1.2 -1.4 02/04/2006 03:50:00 15.8 1.3 19.9 11.5 16 1.4 19.9 11.8 15.5 1.6 19.9 11.1 139 6 128 165 -1.4 0 -1.2 -1.4 02/04/2006 04:00:00 16.8 1.1 20.2 14.1 16.9 1.1 20.2 14.1 16.6 1.3 19.9 13 140 6 145 165 -1.3 0 -1.2 -1.4 02/04/2006 04:10:00 17.3 1.7 21 13.3 17.5 1.7 21 12.6 17.4 1.8 21.8 12.2 141 5 139 165 -1.2 0 -1.2 -1.4 02/04/2006 04:20:00 17.3 1.3 20.6 13.3 17.4 1.3 20.6 13.3 17.5 1.4 21.4 12.2 142 6 137 165 -1 0 -1 -1.2 02/04/2006 04:30:00 17 1.5 20.2 13.3 17.3 1.5 20.2 13 16.9 1.7 21.4 12.2 137 8 138 165 -1 0 -1 -1.2 02/04/2006 04:40:00 17.5 1.3 20.6 14.1 17.7 1.3 20.6 14.1 17.5 1.5 21.4 12.6 136 7 124 165 -1 0 -1 -1.2 02/04/2006 04:50:00 16.8 1.7 20.6 12.2 17.1 1.8 21 12.6 16.9 1.9 21.4 11.8 136 8 128 165 -1 0 -0.8 -1.2 02/04/2006 05:00:00 17.4 1.8 21.8 11.5 17.5 1.8 21.8 11.1 17.3 2 22.6 10.7 140 6 140 165 -0.9 0 -0.8 -1.2 02/04/2006 05:10:00 17 1.8 21.4 11.5 17.1 1.9 22.1 11.8 16.8 1.8 21 11.5 139 7 139 165 -1 0 -0.8 -1.2 02/04/2006 05:20:00 16.1 1.5 21 12.2 16.3 1.5 21 12.6 16 1.7 20.6 11.8 133 8 135 165 -0.9 0 -0.8 -1.2 02/04/2006 05:30:00 17.6 2.1 21.8 11.1 17.8 2.1 22.1 10.3 17.3 2.2 21.8 11.5 135 7 138 165 -0.9 0 -0.8 -0.8 02/04/2006 05:40:00 16.9 1.8 20.6 11.5 17 1.8 21 12.6 16.6 1.9 20.2 12.2 133 8 138 165 -0.9 0 -0.8 -0.8 02/04/2006 05:50:00 17 1.4 21.4 12.2 17.2 1.5 21.4 11.1 16.7 1.6 21.8 11.1 131 7 119 165 -0.8 0 -0.5 -0.8 02/04/2006 06:00:00 17.4 2.1 22.6 12.6 17.6 2.1 22.6 12.6 17.1 2.3 22.1 11.5 131 7 133 165 -0.7 0 -0.5 -0.8 02/04/2006 06:10:00 17.3 1.6 21 13 17.6 1.7 21.8 13 16.9 1.8 21 11.5 130 7 126 165 -0.6 0 -0.5 -0.8 02/04/2006 06:20:00 18.8 2.3 24.4 12.6 19 2.4 24.4 13 18.7 2.5 23.7 11.8 133 6 130 165 -0.6 0 -0.5 -0.8 02/04/2006 06:30:00 18.8 2 23.7 14.1 19 2.1 23.7 13.7 18.4 2.4 24 12.6 132 7 128 165 -0.6 0 -0.5 -0.8 02/04/2006 06:40:00 18.6 2 23.3 14.5 18.9 2 23.7 14.1 18.5 2.3 23.3 11.1 132 7 132 165 -0.7 0 -0.5 -0.8 02/04/2006 06:50:00 17.5 1.7 22.6 13.7 17.8 1.7 22.9 13.7 17.2 1.9 22.9 11.5 128 7 141 165 -0.6 0 -0.5 -0.8 02/04/2006 07:00:00 20.7 1.9 24.4 13.7 21 1.9 24.8 14.5 20.4 2 24.8 14.9 128 6 128 165 -0.4 0 -0.3 -0.5 02/04/2006 07:10:00 18.8 2.1 24 14.1 19 2.1 24.4 14.5 18.7 2.4 24.4 13 131 6 124 165 -0.3 0 -0.3 -0.5 02/04/2006 07:20:00 18.6 2.3 24 12.6 18.8 2.3 24.8 12.6 18.3 2.3 23.7 11.1 128 7 128 165 -0.3 0 -0.3 -0.3 02/04/2006 07:30:00 18.9 2 24 14.5 19.2 2 24.4 14.1 18.5 2.4 24.4 12.2 126 8 127 165 -0.3 0 -0.3 -0.3 02/04/2006 07:40:00 19.4 2 24.8 14.1 19.6 2 25.2 14.1 18.9 2.3 24.4 13.3 129 8 122 165 -0.3 0 -0.1 -0.3 02/04/2006 07:50:00 19 2.5 25.2 13 19.4 2.5 25.6 13.3 18.8 2.7 25.2 11.8 126 5 126 165 -0.2 0 -0.1 -0.3 02/04/2006 08:00:00 20.9 1.9 26 14.9 21.2 2 26.3 14.9 20.7 2.1 26.3 13.7 128 6 136 165 0 0 0.2 -0.1 02/04/2006 08:10:00 19.9 2 25.6 14.9 20.2 2 26.3 14.9 19.9 2.1 26.3 14.5 133 8 145 165 0.2 0 0.2 0.2 02/04/2006 08:20:00 20.3 2 24.8 16.1 20.5 2.1 25.2 15.6 20.2 2 25.2 14.9 133 7 128 165 -0.2 0.2 0.2 -0.3 02/04/2006 08:30:00 19.9 2.2 26 14.9 20.1 2.2 25.6 14.9 19.6 2.3 25.2 13.7 139 7 145 165 -0.2 0 -0.1 -0.3 02/04/2006 08:40:00 22.9 1.9 27.1 17.2 23.1 1.8 27.5 16.8 22.7 2.3 27.5 14.9 138 7 130 165 -0.2 0 0.2 -0.3 02/04/2006 08:50:00 24.6 1.6 30.2 19.9 24.5 1.6 29.4 20.2 24.2 1.9 30.9 18.7 140 5 140 165 -0.1 0 -0.1 -0.3 02/04/2006 09:00:00 20.1 1.7 24.8 16.4 20 1.7 24.4 15.6 20 2 24.8 15.3 145 5 145 165 0 0 0.2 -0.1 02/04/2006 09:10:00 19.2 1.8 23.7 13 19 1.8 24 12.6 18.3 2 22.6 11.8 139 7 126 165 0.1 0 0.2 -0.3 02/04/2006 09:20:00 18.1 2.4 23.3 13 18 2.4 23.3 12.6 17.6 2.4 21.8 11.8 144 2 145 165 0.1 0 0.2 -0.1 02/04/2006 09:30:00 19.4 2.2 25.2 14.9 19.4 2.3 25.2 14.5 18.8 2.4 25.2 12.6 144 0 145 165 0.2 0 0.2 0.2 02/04/2006 09:40:00 23.2 2.1 27.9 17.6 23 2.2 27.1 17.9 22.6 2.3 27.5 16.4 145 0 145 165 -0.1 0.2 0.2 -0.5 02/04/2006 09:50:00 17 1.9 22.1 11.1 16.8 2 21.8 11.1 16.5 2 21 11.1 144 0 145 165 -0.2 0 -0.1 -0.5 02/04/2006 10:00:00 18.5 3.5 25.2 12.2 18.2 3.5 24.8 12.2 18.1 3.5 24.8 11.8 145 0 145 165 0 0.2 0.2 -0.3 02/04/2006 10:10:00 19.8 2.4 24.4 14.5 19.7 2.3 24 14.9 19.3 2.2 24.4 14.5 145 0 145 165 -0.1 0 0.2 -0.3 02/04/2006 10:20:00 16.1 1.2 18.7 12.6 15.8 1.3 18.3 11.8 15.8 1.3 18.3 10.7 145 0 145 165 0.1 0 0.2 -0.1 02/04/2006 10:30:00 14.8 1.1 17.9 11.8 14.4 1.1 17.6 11.1 14.5 1.2 18.7 11.1 145 0 145 165 0.1 0.1 0.2 -0.1 02/04/2006 10:40:00 19.5 2.7 23.3 13.3 19.2 2.7 23.3 13 19.2 2.7 23.7 14.1 145 0 145 165 0.1 0.3 0.7 -0.3 02/04/2006 10:50:00 21.1 1.3 24.4 17.6 20.7 1.2 24 17.2 20.5 1.3 24.4 16.8 145 0 145 165 -0.1 0 0.2 -0.3 02/04/2006 11:00:00 20.2 1.7 24 15.3 19.8 1.7 23.3 14.5 19.5 1.8 22.9 13.7 145 0 145 165 0.2 0 0.7 -0.1 02/04/2006 11:10:00 20.7 1.7 24.8 16.8 20.3 1.8 24.4 16.4 20.3 1.9 24.8 15.3 145 0 145 165 0.6 0 0.9 0.4 02/04/2006 11:20:00 20.5 2 25.6 14.1 20.2 2.1 25.2 13.7 20.3 2 26 14.1 145 0 145 165 0.8 0 0.9 0.7 02/04/2006 11:30:00 21.7 1.9 25.6 16.4 21.2 2 24.8 15.6 21.6 2.3 26 15.3 145 0 145 165 0.8 0 0.9 0.7 02/04/2006 11:40:00 22 2.1 26.3 16.8 21.4 2 25.6 16.4 21.9 2.2 26.8 16.1 145 0 145 165 0.5 0.2 1.1 0.2 02/04/2006 11:50:00 21.8 1.6 25.6 14.1 21.2 1.6 24.8 13.7 21.6 1.7 25.6 16.1 144 0 145 165 0.2 0 0.4 0.2 02/04/2006 12:00:00 18.6 2.3 25.6 13 18.2 2.3 24.8 13 18.3 2.6 25.6 11.8 144 0 145 165 0.2 0 0.2 -0.1 02/04/2006 12:10:00 21.4 2.6 27.9 16.4 20.9 2.5 26.8 15.6 21.3 2.5 27.1 15.3 144 0 145 165 0.2 0 0.4 0.2 02/04/2006 12:20:00 23.1 2.5 27.5 13.7 22.5 2.5 26.8 13.3 22.7 2.8 27.9 14.9 144 0 145 165 0.4 0.1 0.7 0.2 02/04/2006 12:30:00 21.4 2.1 26.3 16.1 20.9 2 25.6 15.6 21.1 2.3 26.3 14.1 144 0 145 165 0.5 0 0.7 0.2 02/04/2006 12:40:00 19.8 2.1 25.6 13.3 19.3 2.1 24.8 13.7 19.7 2.4 27.1 13.3 144 0 145 165 0.5 0 0.7 0.4 02/04/2006 12:50:00 21.8 2.1 26 16.8 21.2 1.9 25.2 15.6 21.6 2 26 17.2 144 0 145 165 0.5 0 0.9 0.4 02/04/2006 13:00:00 21.5 2 26.3 17.2 20.9 2 25.6 16.8 21.1 2.1 26.8 14.5 144 0 145 165 0.5 0 0.7 0.4 02/04/2006 13:10:00 24 1.9 27.5 18.7 23.4 1.9 27.1 18.3 23.7 2.6 27.9 15.3 144 0 145 165 0.6 0 0.9 0.4 02/04/2006 13:20:00 22.2 2.2 27.1 17.2 21.7 2.1 26.3 17.2 22 2.2 26.3 16.1 144 0 145 165 0.7 0 0.9 0.7 02/04/2006 13:30:00 21.1 1.7 24.4 16.4 20.7 1.7 24 16.1 21 1.7 24.8 16.4 144 0 145 165 0.6 0 0.9 0.7 02/04/2006 13:40:00 17.8 2 23.3 13 17.6 2 22.9 12.6 17.8 2.1 23.7 12.6 144 0 145 165 0.8 0.1 0.9 0.7 02/04/2006 13:50:00 19.5 1.8 24.4 15.3 19.4 1.8 24 15.3 19.6 1.7 24 16.1 144 0 145 165 0.8 0 0.9 0.7 02/04/2006 14:00:00 19.5 1.9 26.8 15.6 19.3 2 26.3 15.6 19.4 2.2 25.2 14.1 144 0 145 165 0.8 0 0.9 0.9 02/04/2006 14:10:00 20.2 2 24.8 13.7 20 2 24.4 13.7 20 2.2 24.4 13.3 144 0 145 165 0.9 0 1.1 0.9 02/04/2006 14:20:00 19.8 1.6 23.3 15.3 19.5 1.6 22.9 15.3 19.7 1.9 23.3 14.5 144 0 145 165 0.9 0 1.4 0.9 02/04/2006 14:30:00 20.8 2.2 26 16.1 20.6 2.3 25.6 15.6 20.9 2.4 27.5 15.6 144 0 145 165 0.8 0 0.9 0.9 02/04/2006 14:40:00 19 1.5 22.1 14.9 18.5 1.6 21.8 14.1 19.2 1.7 22.9 14.1 144 0 145 165 0.8 0 0.9 0.9 02/04/2006 14:50:00 18.6 2 24.4 13.3 18.3 2.2 24 12.6 18.5 2.1 23.3 13 144 0 145 165 0.9 0 0.9 0.9 02/04/2006 15:00:00 19 1.8 23.7 13.7 18.8 1.9 23.7 13 18.8 2.1 24.8 12.6 144 0 145 165 0.8 0 0.9 0.7 02/04/2006 15:10:00 17.5 2.5 21.8 11.8 17.1 2.6 21.4 11.1 17.2 2.7 22.1 11.1 144 0 145 165 0.8 0 0.9 0.9 02/04/2006 15:20:00 16.3 1.7 21.8 12.6 15.8 1.8 21.4 12.2 15.9 2 22.9 11.1 144 0 145 165 0.8 0 0.9 0.9 02/04/2006 15:30:00 15.1 2.2 20.6 10.7 15.1 2.2 20.6 11.1 14.6 2.3 21.8 9.5 144 0 145 165 0.8 0 0.9 0.9 02/04/2006 15:40:00 16.4 2.3 22.1 11.8 16.2 2.2 21.8 11.5 15.9 2.8 23.3 10.7 144 0 145 165 0.9 0 0.9 0.9 02/04/2006 15:50:00 16.1 1.5 19.5 11.8 15.9 1.5 19.5 12.6 15.8 1.7 20.2 11.5 144 0 145 165 0.9 0 0.9 0.9 02/04/2006 16:00:00 15.4 1.7 19.5 10.7 15.3 1.6 19.1 10.3 15.1 1.9 19.9 10.3 144 0 145 165 0.9 0 0.9 0.9 02/04/2006 16:10:00 14.8 2 19.9 9.5 14.6 2.2 19.5 9.5 14.4 2.1 19.9 9.1 144 0 145 165 0.9 0 0.9 0.9 02/04/2006 16:20:00 13.2 1.6 17.6 9.5 13.4 1.5 17.9 10.3 12.9 1.7 18.3 9.9 144 0 145 165 0.9 0 1.1 0.9 02/04/2006 16:30:00 14.6 2.1 20.2 9.1 14.9 2.1 19.9 9.5 14.4 2.4 19.9 9.5 144 0 145 165 0.9 0 1.1 0.9 02/04/2006 16:40:00 14 1.8 18.3 9.1 14.2 1.7 18.3 10.3 13.9 2 19.1 9.5 144 0 145 165 1 0 1.1 0.9 02/04/2006 16:50:00 13.8 2.5 19.5 9.1 13.7 2.6 19.5 9.1 13.8 2.5 19.5 9.5 144 0 145 165 1.1 0 1.4 0.9 02/04/2006 17:00:00 13.2 2.1 18.3 7.6 13.3 2.2 18.3 7.2 13 2.2 19.1 8 144 0 145 165 0.9 0 1.1 0.9 02/04/2006 17:10:00 12.3 1.7 16.1 7.2 12.6 1.6 16.4 7.6 12.4 1.7 17.2 7.6 144 0 145 165 0.9 0 1.1 0.9 02/04/2006 17:20:00 12.7 1.9 17.6 8.4 12.7 2.1 17.6 6.5 12.5 2.2 17.6 6.8 144 0 145 165 0.9 0 1.1 0.9 02/04/2006 17:30:00 13.1 1.4 17.2 9.1 12.8 1.5 17.2 8.8 13 1.4 16.8 9.1 144 0 145 165 0.9 0 1.1 0.9 02/04/2006 17:40:00 14.1 1.5 17.6 9.5 14 1.5 17.2 9.9 13.5 1.7 17.2 9.1 144 0 145 165 1 0 1.1 0.9 02/04/2006 17:50:00 14.1 1.7 17.9 10.7 14.1 1.7 17.9 10.3 13.8 2 19.1 8.8 144 0 145 165 1.2 0.1 1.4 1.1 02/04/2006 18:00:00 15.7 2.1 21.8 10.7 16.1 2 21.8 11.5 15.4 2 20.2 10.3 144 0 145 165 1.4 0 1.6 1.4 02/04/2006 18:10:00 14.9 1.5 19.1 10.7 15.3 1.4 19.1 11.8 14.3 1.7 19.1 10.3 144 0 145 165 1.4 0 1.6 1.4 02/04/2006 18:20:00 14.4 2.1 20.2 10.3 14.4 2 20.2 10.3 14.2 2.1 19.9 10.3 144 0 145 165 1.5 0 1.6 1.4 02/04/2006 18:30:00 13.4 2.5 16.8 7.6 14.6 1.2 17.6 10.7 14 1.3 16.8 11.1 144 0 145 165 1.5 0 1.8 1.6 02/04/2006 18:40:00 7.9 0.2 8.4 7.2 14.6 1.4 17.2 11.1 14.4 1.3 17.2 10.7 144 0 145 165 1.6 0 1.6 1.6 02/04/2006 18:50:00 7.9 0.2 8.4 6.8 14 1.3 16.8 9.9 13.9 1.3 17.2 10.3 144 0 145 165 1.7 0 1.8 1.6 02/04/2006 19:00:00 8.1 0.2 8.8 7.6 14.7 1.4 18.3 11.5 14 1.5 17.2 10.7 144 1 145 165 1.8 0.1 1.8 1.6 02/04/2006 19:10:00 8.3 0.2 8.8 8 14.1 1.2 16.8 10.3 14.2 1.4 17.6 8.8 142 5 144 165 2 0 2.3 1.8 02/04/2006 19:20:00 8.4 0.2 9.1 8 11.4 2.2 16.4 8.8 9.1 0.2 9.5 8.8 142 5 136 165 2.1 0 2.3 2.1 02/04/2006 19:30:00 8.5 0.2 8.8 8 9.1 0.2 9.5 8.4 9.1 0.2 9.5 8.4 142 6 133 165 2.3 0 2.3 2.1 02/04/2006 19:40:00 8.7 0.2 9.1 7.6 10.5 2.6 18.3 8.4 10.4 2.3 18.3 8.8 140 6 147 165 2.3 0 2.6 2.3 02/04/2006 19:50:00 13.6 2.6 18.3 8.8 15.5 1.3 19.1 12.6 10.4 0.8 16.1 9.5 144 6 150 165 2.4 0 2.6 2.3 02/04/2006 20:00:00 15.3 1.3 19.1 11.8 15.4 1.4 19.5 12.2 12.6 2.7 18.3 9.5 140 6 133 165 2.5 0 2.8 2.6 02/04/2006 20:10:00 15.4 1.2 17.9 12.2 15.4 1.2 18.3 12.6 14.8 1.8 17.9 10.3 142 6 143 165 2.7 0 2.8 2.6 02/04/2006 20:20:00 14.5 1.5 17.6 10.7 14.5 1.6 17.9 10.7 14.2 1.8 17.9 9.9 148 5 142 165 2.3 0.4 2.8 1.8 02/04/2006 20:30:00 12.7 1.8 16.8 8.4 12.7 1.9 16.8 8.4 12 2.1 16.8 8 143 8 126 165 2.3 0.2 2.8 1.8 02/04/2006 20:40:00 12.8 1 15.6 10.7 12.8 1 15.3 11.1 12.6 1.2 15.3 9.1 153 4 150 165 2.3 0 2.6 2.3 02/04/2006 20:50:00 13.6 1.5 16.8 10.3 13.7 1.5 16.8 10.3 13.2 1.6 16.8 9.5 143 6 139 165 2.7 0.2 3 2.3 02/04/2006 21:00:00 14.2 1 16.4 11.5 14.3 1 16.8 11.5 14.2 1.1 16.8 10.7 139 6 136 165 3 0 3 2.8 02/04/2006 21:10:00 16.4 1.7 21.8 12.2 16.5 1.7 21.4 12.6 16.2 1.8 21.8 12.2 140 7 142 165 3 0 3 2.8 02/04/2006 21:20:00 17.5 1.5 21.4 13.3 17.6 1.5 21.8 13.7 17.2 1.6 22.1 13.7 140 7 134 165 2.9 0 3 2.6 02/04/2006 21:30:00 16.1 1.4 19.5 12.6 16.2 1.4 19.5 12.6 16 1.5 19.9 13 142 6 142 165 2.9 0 3 2.8 02/04/2006 21:40:00 18.3 1.7 22.9 14.1 18.3 1.7 22.9 13.7 18.1 1.7 22.6 13 143 5 128 165 3.1 0 3.3 2.8 02/04/2006 21:50:00 18.2 1.7 21.4 13.7 18.2 1.7 21.4 14.1 17.6 1.9 21.8 12.6 148 4 152 165 2.9 0 3.3 2.8 02/04/2006 22:00:00 17.7 1.2 19.9 13.7 17.7 1.2 20.6 13.7 17.4 1.3 20.2 13.7 145 5 137 165 3 0 3.3 2.8 02/04/2006 22:10:00 16.5 1.2 19.1 13.3 16.5 1.2 19.1 13.7 16.1 1.3 19.1 12.2 145 4 145 165 3.2 0 3.3 3 02/04/2006 22:20:00 16.6 1.2 19.5 13.7 16.6 1.2 19.5 13.7 16.6 1.5 19.9 13 145 4 149 165 3.2 0 3.3 3 02/04/2006 22:30:00 17.2 1.3 19.9 13.3 17.3 1.3 20.2 13.3 17 1.5 20.2 12.2 144 5 145 165 3.2 0 3.3 3.3 02/04/2006 22:40:00 17.5 1.1 20.2 14.1 17.5 1.1 20.2 14.5 17.3 1.2 20.2 13.7 144 5 145 165 3.2 0 3.3 3.3 02/04/2006 22:50:00 17.3 1.4 21 13.3 17.3 1.4 21.4 14.1 17.1 1.6 21 12.6 144 6 145 165 3.2 0 3.3 3.3 02/04/2006 23:00:00 17.7 1.3 21.4 14.1 17.8 1.4 21.4 13.7 17.5 1.5 20.6 11.5 143 6 145 165 3.2 0 3.3 3 02/04/2006 23:10:00 19.2 1.1 22.6 16.1 19.4 1.2 22.6 16.1 19 1.3 22.9 14.1 140 5 147 165 3.2 0 3.5 3.3 02/04/2006 23:20:00 19.4 1.3 22.9 15.6 19.6 1.3 22.9 15.6 19.4 1.5 22.9 14.5 139 5 138 165 3.2 0 3.3 3.3 02/04/2006 23:30:00 19.7 1.5 23.3 13 19.8 1.6 23.3 13.3 19.3 1.6 23.3 13.3 139 6 137 165 3.2 0 3.3 3.3 02/04/2006 23:40:00 19.7 1.3 23.3 15.3 19.8 1.4 23.3 15.3 19.6 1.5 23.3 14.1 140 5 147 165 3.2 0 3.3 3 02/04/2006 23:50:00 19.8 1.5 23.7 15.6 20 1.5 24 15.6 19.6 1.6 24 14.9 140 6 119 165 3.2 0 3.3 3 02/05/2006 00:00:00 19.1 2.2 25.2 14.9 19.2 2.2 25.2 14.9 19 2.4 25.2 13.3 144 6 145 165 3 0 3.5 3 02/05/2006 00:10:00 18.1 1.2 22.1 14.5 18.3 1.2 22.1 14.5 18 1.3 21.4 14.1 141 6 147 165 3 0 3.3 3 02/05/2006 00:20:00 18.8 1.5 23.3 14.5 19 1.6 22.9 14.5 18.5 2 23.3 13.3 139 6 141 165 3 0 3.3 3 02/05/2006 00:30:00 18.7 1.3 22.1 15.3 18.8 1.4 21.8 15.3 18.5 1.4 22.1 14.9 140 6 135 165 3 0 3.3 3 02/05/2006 00:40:00 18.7 1.5 22.1 15.3 18.7 1.5 22.1 15.3 18.4 1.5 22.6 14.1 139 6 135 165 3 0 3.3 3 02/05/2006 00:50:00 18.6 1.6 22.9 14.5 18.7 1.5 22.1 14.9 18.6 1.7 23.7 13 141 5 141 165 3 0 3.3 3 02/05/2006 01:00:00 18.3 1.5 22.1 14.1 18.4 1.5 22.1 14.1 18 1.5 22.9 13.3 140 6 145 165 3.1 0 3.3 3 02/05/2006 01:10:00 17.2 1.6 21.4 12.6 17.3 1.5 21 13.7 16.9 1.7 21.4 13 138 7 149 165 3.1 0 3.3 3 02/05/2006 01:20:00 16.2 1.5 20.2 11.8 16.4 1.5 20.2 12.2 15.9 1.7 20.2 11.1 136 8 150 165 3 0 3.3 2.8 02/05/2006 01:30:00 17.9 1.7 21.4 13.3 18.1 1.7 21.4 13.3 17.7 1.7 21 12.6 139 7 136 165 2.9 0 3.3 2.8 02/05/2006 01:40:00 15.5 1.5 20.6 11.8 15.7 1.5 21 11.5 15.3 1.5 21 10.7 138 6 125 165 2.9 0 3 2.8 02/05/2006 01:50:00 16.5 1.5 20.2 12.6 16.7 1.5 20.2 12.2 16.3 1.7 20.6 11.5 135 8 142 165 2.9 0 3 2.8 02/05/2006 02:00:00 16.4 1.5 20.6 11.8 16.6 1.5 20.6 11.8 16.1 1.5 20.6 11.5 136 8 143 165 3 0 3 2.8 02/05/2006 02:10:00 17.7 1.6 21.4 13 17.9 1.7 21.8 12.6 17.4 1.9 21.8 12.2 134 7 133 165 3 0 3 2.8 02/05/2006 02:20:00 18.3 1.7 22.6 13.7 18.5 1.7 22.6 14.1 18 1.7 23.7 13.7 136 8 121 165 2.9 0 3.3 2.8 02/05/2006 02:30:00 17.9 1.5 21.4 13.7 18.2 1.5 22.1 12.6 17.5 1.9 21.8 12.2 131 7 128 165 2.9 0 3 2.8 02/05/2006 02:40:00 18 2.1 23.7 12.6 18.1 2.1 24.4 13.3 17.8 2.2 23.3 13 132 7 133 165 3 0 3 3 02/05/2006 02:50:00 17 1.8 22.1 12.6 17.2 1.8 21.4 13 16.6 2.2 21.8 11.8 132 8 110 165 3 0 3 2.8 02/05/2006 03:00:00 16.9 1.5 20.6 11.5 17.1 1.6 20.6 10.3 16.6 1.6 20.6 11.5 133 7 138 165 3 0 3 2.8 02/05/2006 03:10:00 17.4 1.9 22.1 13.3 17.6 1.9 21.8 13 17.1 2.4 22.6 11.5 134 8 142 165 3 0 3 2.8 02/05/2006 03:20:00 17.8 1.5 22.6 13 18.1 1.5 22.6 13.7 17.3 1.7 21.8 13.3 133 7 145 165 2.9 0 3 2.8 02/05/2006 03:30:00 18.1 1.4 21.8 14.9 18.4 1.4 21.8 14.5 17.6 1.6 22.6 13.3 133 8 137 165 2.9 0 3 2.8 02/05/2006 03:40:00 19.5 1.9 24 14.5 19.7 1.9 24.4 14.5 19.3 2.3 25.2 13.3 137 8 139 165 2.7 0.1 3 2.6 02/05/2006 03:50:00 18.7 1.7 22.9 13.3 18.9 1.7 23.3 13.7 18.7 2 22.9 13 138 8 141 165 2.4 0 2.6 2.3 02/05/2006 04:00:00 16.5 1.8 20.6 11.1 16.7 1.8 21 11.8 16.2 1.9 20.2 10.7 132 7 137 165 2.5 0 2.8 2.3 02/05/2006 04:10:00 18.5 1.6 22.6 14.5 18.7 1.7 22.9 14.5 17.9 1.8 22.6 11.8 134 8 134 165 2.9 0 3 2.8 02/05/2006 04:20:00 18 1.5 22.6 14.5 18.2 1.5 22.6 14.1 17.6 1.7 21.8 13 137 7 138 165 2.9 0 3 2.8 02/05/2006 04:30:00 18.5 1.5 21.4 13.7 18.7 1.5 21.8 14.1 18.4 1.8 22.1 13 143 6 151 165 2.7 0 2.8 2.6 02/05/2006 04:40:00 18.1 1.4 21.8 14.9 18.3 1.5 21.8 14.9 17.8 1.4 21 14.1 142 5 144 165 2.4 0 2.6 2.3 02/05/2006 04:50:00 18.2 1.8 22.1 12.6 18.3 1.7 22.6 13.3 18 1.9 23.3 13 144 5 147 165 2.4 0 2.6 2.3 02/05/2006 05:00:00 16.2 1.7 20.6 13.3 16.3 1.7 20.6 13.3 16 1.7 21 13 145 5 146 165 2.3 0.1 2.6 2.1 02/05/2006 05:10:00 13.6 0.7 15.3 11.1 13.6 0.7 15.3 11.1 13.5 0.9 15.6 10.7 144 5 144 165 2.7 0.1 3 2.6 02/05/2006 05:20:00 17.1 1.3 20.2 11.8 17.2 1.3 20.6 12.6 16.9 1.3 20.2 13 145 6 121 165 2.7 0.2 3 2.6 02/05/2006 05:30:00 14.4 1 16.8 11.5 14.5 1 16.8 11.8 14.3 1.1 17.2 10.7 146 5 156 165 2.7 0 2.8 2.6 02/05/2006 05:40:00 13.7 0.9 16.1 10.7 13.8 0.9 16.1 11.5 13.5 1 16.1 10.7 140 5 145 165 2.9 0 2.8 2.8 02/05/2006 05:50:00 15.1 1 17.6 12.2 15.1 1 17.2 12.2 14.9 1.1 17.6 11.5 145 4 149 165 2.7 0 3 2.6 02/05/2006 06:00:00 13.4 1.1 17.2 10.7 13.5 1.1 17.9 11.1 13.2 1 15.3 10.3 142 6 131 165 2.7 0 2.8 2.6 02/05/2006 06:10:00 17 2.2 22.1 10.3 17.2 2.3 22.6 10.7 16.8 2.4 22.1 9.1 137 7 139 165 2.6 0 2.8 2.6 02/05/2006 06:20:00 16.9 1.2 20.2 12.6 17 1.2 20.2 12.6 16.7 1.2 20.2 12.6 140 6 143 165 2.6 0 2.8 2.6 02/05/2006 06:30:00 19.1 2.6 23.7 13.7 19.2 2.6 24 13.3 18.8 2.7 24 12.6 144 6 144 165 2.6 0.2 2.8 2.3 02/05/2006 06:40:00 17.3 1.9 20.6 12.2 17.2 2 21 11.8 17.1 2.1 20.6 10.7 149 5 145 165 1.8 0 2.3 1.6 02/05/2006 06:50:00 12.3 1.4 16.4 9.9 12.2 1.3 16.4 9.5 12.3 1.4 16.4 9.5 152 5 145 165 1.6 0 1.8 1.6 02/05/2006 07:00:00 8.5 0.9 11.1 6.5 8.4 0.9 10.7 6.1 8.5 0.9 11.1 6.8 156 0 157 165 1.6 0 1.6 1.6 02/05/2006 07:10:00 6.8 0.4 7.6 5.7 6.7 0.4 7.6 5.7 6.8 0.4 7.6 5.7 156 0 157 165 1.6 0 1.6 1.6 02/05/2006 07:20:00 6.7 0.2 7.2 6.1 6.6 0.2 7.2 6.1 6.8 0.3 7.2 6.1 156 0 157 165 1.6 0 1.8 1.6 02/05/2006 07:30:00 8.1 0.8 9.5 6.1 8 0.8 9.5 6.1 8.1 0.8 9.9 6.5 156 0 157 165 1.6 0 1.6 1.6 02/05/2006 07:40:00 8 0.4 9.1 6.8 7.9 0.4 8.8 6.8 8 0.5 9.1 6.8 156 0 157 165 1.5 0 1.6 1.4 02/05/2006 07:50:00 7.5 0.4 9.1 6.5 7.5 0.4 8.4 6.5 7.5 0.4 8.4 6.1 156 0 157 165 1.5 0 1.6 1.4 02/05/2006 08:00:00 7.8 0.8 9.5 6.5 7.6 0.7 9.1 6.1 7.8 0.6 9.5 6.1 157 0 157 165 1.6 0 1.6 1.4 02/05/2006 08:10:00 9.7 0.8 11.5 8 9.6 0.8 11.5 8 9.5 0.8 11.5 7.2 156 1 157 165 1.7 0 1.8 1.6 02/05/2006 08:20:00 13.5 1.7 16.1 8 13.3 1.7 16.1 8 13.3 1.8 16.1 7.2 146 5 147 165 1.7 0 1.8 1.6 02/05/2006 08:30:00 9.8 1.8 14.1 6.1 9.7 1.8 13.7 6.5 9.6 1.7 14.1 6.5 159 13 154 165 1.7 0 1.8 1.6 02/05/2006 08:40:00 8.5 0.9 11.1 6.1 8.4 0.9 10.7 6.1 8.4 0.9 10.7 6.5 154 9 153 165 1.7 0 1.8 1.6 02/05/2006 08:50:00 10.6 1 13.3 8 10.4 1 13 8 10.4 1.1 13.3 8 150 5 158 165 1.7 0 1.8 1.6 02/05/2006 09:00:00 11.3 0.7 13.3 8.8 11.6 0.7 13.3 9.5 11.7 0.8 13.3 9.5 149 5 151 165 1.8 0 1.8 1.6 02/05/2006 09:10:00 12.9 1.2 15.6 9.9 13 1.1 15.3 10.3 13.1 1.1 15.6 10.7 158 13 164 165 1.7 0 1.8 1.6 02/05/2006 09:20:00 12.2 1.1 14.9 9.5 12.4 1 14.9 9.5 12.4 1.3 15.3 9.1 157 12 167 165 1.8 0 1.8 1.6 02/05/2006 09:30:00 14.1 1.1 16.4 11.5 14.1 1.1 16.4 11.5 14.6 1 17.2 12.2 153 4 152 165 1.8 0 1.8 1.6 02/05/2006 09:40:00 13.3 1.1 15.6 11.1 13.4 1.1 15.6 11.1 13.8 1 16.1 11.5 151 3 148 165 1.7 0 1.8 1.6 02/05/2006 09:50:00 12.6 0.6 14.5 11.1 12.6 0.6 14.5 11.1 12.6 0.8 14.5 10.7 150 3 147 165 1.7 0 1.8 1.6 02/05/2006 10:00:00 13.2 0.8 15.3 11.1 13.2 0.9 15.3 11.1 13.3 0.8 15.3 10.7 150 4 145 165 1.8 0 1.8 1.6 02/05/2006 10:10:00 13.5 0.7 15.3 11.5 13.5 0.7 16.1 11.5 13.9 0.8 15.6 11.5 149 2 148 165 1.7 0 1.8 1.6 02/05/2006 10:20:00 13.4 0.8 16.1 11.5 13.4 0.8 15.6 11.5 13.9 1 17.9 11.1 148 0 148 165 1.7 0 1.8 1.6 02/05/2006 10:30:00 12.5 1.9 16.4 7.6 12.6 1.8 16.4 8.4 13 2.1 17.2 8.8 148 0 148 165 1.7 0 1.8 1.6 02/05/2006 10:40:00 13.3 1 16.4 10.7 13.4 1 16.4 11.1 13.8 1.1 16.4 10.3 148 0 148 165 1.7 0 1.8 1.6 02/05/2006 10:50:00 12.5 0.8 14.1 10.3 12.6 0.8 14.5 10.3 12.9 1 14.9 10.3 148 0 148 165 1.8 0 1.8 1.6 02/05/2006 11:00:00 11.9 1.3 15.3 9.5 12.2 1.3 15.6 9.5 12.4 1.3 15.3 9.5 148 0 148 165 2 0 2.3 1.8 02/05/2006 11:10:00 13.1 0.9 15.3 10.7 13.4 0.9 15.3 10.7 13.4 1.1 15.6 9.5 148 2 147 165 2.2 0.3 2.8 1.8 02/05/2006 11:20:00 12.6 1 15.6 10.3 12.8 1 15.3 10.3 12.6 1.1 15.3 8.8 147 5 150 165 2.8 0 3 2.6 02/05/2006 11:30:00 14.8 1.3 17.6 11.8 14.9 1.3 17.9 11.8 14.6 1.5 17.9 11.1 147 5 153 165 2.4 0.2 3 2.1 02/05/2006 11:40:00 15.7 1.3 18.3 11.8 15.8 1.3 19.1 11.8 15.5 1.5 18.3 11.1 146 5 146 165 2.1 0.2 2.6 1.8 02/05/2006 11:50:00 15 0.9 17.2 12.6 15.2 0.9 17.6 13 14.8 1 17.2 12.2 142 5 141 165 2.2 0 2.6 2.1 02/05/2006 12:00:00 16.5 1 18.7 14.1 16.5 1 18.7 14.1 16.4 1.2 19.1 12.6 144 5 145 165 2.2 0.1 2.6 1.8 02/05/2006 12:10:00 15.1 0.9 17.6 13 15.1 0.9 17.6 12.6 14.9 1 17.9 11.5 147 5 142 165 2 0 2.3 1.8 02/05/2006 12:20:00 15.6 1.8 19.1 11.5 15.7 1.8 19.1 11.5 15.5 2 19.1 11.1 145 5 139 165 1.9 0.1 2.3 1.6 02/05/2006 12:30:00 14.4 2.2 20.2 11.1 14.4 2.1 19.9 11.1 14.3 2.2 19.9 10.3 149 3 153 165 1.7 0 1.8 1.6 02/05/2006 12:40:00 12.7 1.9 17.9 9.5 12.7 1.8 17.6 9.5 12.3 1.7 17.6 8.8 147 5 143 165 1.7 0 1.8 1.6 02/05/2006 12:50:00 13.7 1 16.1 10.7 13.4 1 15.6 10.7 13.1 1.1 15.6 9.5 147 3 145 165 1.6 0 1.6 1.4 02/05/2006 13:00:00 11.6 1.2 13.7 8.4 11.4 1.1 13.7 9.1 10.9 1.3 13.7 6.8 146 5 148 165 1.7 0 1.8 1.6 02/05/2006 13:10:00 10.3 1 13.3 8 10.4 1 13.3 8.8 10.1 1.1 13.3 7.2 138 5 130 165 1.7 0 1.8 1.6 02/05/2006 13:20:00 11.5 2 15.6 7.2 11.6 1.9 15.6 7.2 11 2 15.3 6.8 131 8 139 165 1.9 0 1.8 1.8 02/05/2006 13:30:00 12.9 1.7 16.8 8.8 13 1.7 16.8 9.1 12.5 1.6 16.8 8.8 131 8 140 165 1.8 0 1.8 1.8 02/05/2006 13:40:00 12.9 1.2 15.6 9.1 13 1.2 16.1 9.1 12.7 1.5 16.1 8.8 138 6 142 165 1.9 0 1.8 1.8 02/05/2006 13:50:00 13.1 1.5 17.9 8 13.2 1.6 18.7 8 13.1 1.7 17.9 8 133 7 115 165 1.9 0 1.8 1.8 02/05/2006 14:00:00 13.6 1.5 17.2 9.1 13.8 1.5 17.2 9.9 13.4 1.5 17.6 9.1 124 7 129 165 1.9 0 2.1 1.8 02/05/2006 14:10:00 13.4 1.6 17.6 9.9 13.7 1.7 17.9 9.5 13 1.7 18.7 9.1 121 6 115 165 2 0 2.3 1.8 02/05/2006 14:20:00 12.6 1.5 16.1 6.5 12.9 1.5 16.4 6.8 12.2 1.5 15.3 6.5 115 8 124 165 2 0 2.1 1.8 02/05/2006 14:30:00 13.7 1.5 17.9 9.9 13.9 1.6 18.3 9.1 13 1.8 17.9 7.2 109 7 109 165 2 0 2.3 1.8 02/05/2006 14:40:00 13.2 1.4 16.4 9.9 13.4 1.4 16.8 9.9 12.6 1.7 16.8 8 108 7 112 165 2.1 0 2.3 1.8 02/05/2006 14:50:00 15 1.9 19.5 9.5 15.3 2 20.2 9.5 14.2 2 18.7 8 106 7 111 165 2 0 2.3 1.8 02/05/2006 15:00:00 16.3 2.9 23.3 8.4 16.6 2.8 23.3 8.8 15.6 2.9 22.1 9.1 112 7 112 165 1.7 0 1.8 1.6 02/05/2006 15:10:00 14.3 2.3 18.7 7.6 14.5 2.3 19.1 8 13.4 2.3 17.9 6.8 106 7 105 165 1.8 0 1.8 1.8 02/05/2006 15:20:00 14.4 1.7 18.3 9.9 14.7 1.7 19.1 9.9 13.3 1.9 18.3 8.4 104 9 104 165 1.9 0 1.8 1.8 02/05/2006 15:30:00 15 2.6 21.4 9.5 15.4 2.6 21.8 9.5 14 2.6 20.2 8 105 7 101 165 1.7 0 1.8 1.6 02/05/2006 15:40:00 14 2.4 21.4 8 14.3 2.5 22.6 8 13.1 2.3 19.9 7.6 105 9 104 165 1.6 0 1.8 1.6 02/05/2006 15:50:00 14.7 1.5 18.3 9.5 15.2 1.6 18.7 10.3 13.7 1.7 17.6 9.1 93 6 102 165 1.6 0 1.6 1.4 02/05/2006 16:00:00 14.7 2 19.9 8.4 15.1 2 19.9 9.1 13.8 2.1 18.7 8.4 88 7 84 165 1.6 0 1.6 1.6 02/05/2006 16:10:00 14.3 2.2 19.5 8 14.8 2.3 20.2 8 13.5 2.2 19.5 8.8 83 7 92 165 1.6 0 1.6 1.4 02/05/2006 16:20:00 13.9 1.8 19.1 9.1 14.3 1.9 19.5 9.1 13 1.8 18.3 8 75 8 70 165 1.6 0 1.8 1.6 02/05/2006 16:30:00 13.5 1.8 18.3 8.4 13.9 1.9 19.1 8.8 12.9 1.7 17.9 8.8 75 9 73 165 1.7 0 1.8 1.6 02/05/2006 16:40:00 14.4 1.9 18.7 8.8 14.7 2 19.5 8.4 13.6 1.8 18.7 8 74 9 67 165 1.7 0 1.8 1.6 02/05/2006 16:50:00 15.6 2.7 22.1 9.5 16 2.8 22.6 9.9 14.8 2.6 21.8 9.5 74 9 80 165 1.7 0 1.8 1.6 02/05/2006 17:00:00 15.5 2.4 21 10.3 15.9 2.5 22.1 10.3 14.7 2.2 21 10.7 78 8 85 165 1.7 0 1.8 1.6 02/05/2006 17:10:00 16.3 2.2 21 11.5 16.7 2.2 21.8 11.5 15.5 2.2 20.6 10.7 78 8 88 165 1.7 0 1.8 1.6 02/05/2006 17:20:00 17.3 1.8 21.8 12.2 17.7 1.9 22.9 12.2 16.3 1.9 21 11.1 83 8 83 165 1.7 0 1.8 1.6 02/05/2006 17:30:00 16.9 2.3 23.3 10.7 17.7 2.3 24 10.7 16.1 2.2 22.6 9.9 87 9 89 165 1.8 0 1.8 1.6 02/05/2006 17:40:00 19.9 2.3 26.3 13 20.2 2.4 27.1 13 18.6 2.4 26.8 12.6 91 8 98 165 1.8 0 1.8 1.6 02/05/2006 17:50:00 20.5 1.8 25.2 15.6 21 1.9 26 16.4 19.5 2.1 24.4 14.1 88 8 84 165 1.9 0 1.8 1.8 02/05/2006 18:00:00 20.8 2.8 27.5 13.3 21.3 2.8 27.9 13.7 19.6 2.7 26.8 13 90 8 99 165 1.9 0 1.8 1.8 02/05/2006 18:10:00 19.5 2.6 25.2 12.2 19.8 2.7 26 11.8 18.1 2.6 25.2 11.1 91 8 94 165 2 0 2.3 1.8 02/05/2006 18:20:00 20.4 2.7 26.8 12.2 20.6 2.7 26.8 12.2 19.1 2.6 26.3 12.6 98 8 102 165 2.1 0 2.3 1.8 02/05/2006 18:30:00 22.5 3.3 29.4 11.8 22.8 3.3 30.2 12.6 21.7 3.5 29.1 13 104 7 114 165 2.2 0 2.3 2.1 02/05/2006 18:40:00 21.8 2.8 30.2 14.9 22.1 2.8 30.6 14.5 20.9 3.1 31.8 13.3 108 8 110 165 2.3 0 2.3 2.3 02/05/2006 18:50:00 20.6 2.4 26 13.7 20.9 2.4 26.3 13.3 19.7 2.4 24.8 13.7 115 9 117 165 2.4 0 2.6 2.3 02/05/2006 19:00:00 21.7 2.8 27.9 14.1 22 2.8 28.7 14.5 20.8 3.1 27.9 13.3 118 8 106 165 2.7 0.1 3 2.6 02/05/2006 19:10:00 22.2 2 27.9 17.2 22.5 2 27.9 17.6 21.7 2.5 28.7 16.4 124 8 119 165 3 0 3.3 2.8 02/05/2006 19:20:00 22 2 27.1 16.8 22.3 2 27.5 17.2 21.3 2.5 27.1 15.6 131 9 133 165 3.1 0 3.3 3 02/05/2006 19:30:00 21.1 2.3 27.5 15.3 21.3 2.3 27.5 14.9 20.5 2.3 27.1 14.9 135 7 139 165 3.3 0 3.5 3.3 02/05/2006 19:40:00 22.6 2.8 28.7 16.4 22.8 2.9 28.7 15.6 22.3 3.1 29.8 15.3 138 7 133 165 3.3 0 3.5 3.3 02/05/2006 19:50:00 23.2 1.9 28.7 17.9 23.2 1.9 28.7 17.2 23 2.1 29.4 16.8 140 7 139 165 3.2 0 3.3 3 02/05/2006 20:00:00 24.6 1.7 28.7 18.3 24.5 1.8 28.7 18.7 24.5 2.1 29.1 17.2 145 4 138 165 2.9 0 3.3 2.8 02/05/2006 20:10:00 21.9 1.9 26 16.4 22 1.9 26.3 16.8 21.4 2.1 26.3 16.4 145 6 145 165 2.5 0.1 2.8 2.3 02/05/2006 20:20:00 21.5 2.1 26.3 17.2 21.5 2.1 26.8 17.2 21 2.4 26.8 16.4 146 5 137 165 2.4 0.1 2.6 2.3 02/05/2006 20:30:00 21.1 1.3 24.4 16.8 21.2 1.3 24.8 17.2 20.9 1.5 24.4 15.6 145 5 131 165 2.4 0 2.6 2.3 02/05/2006 20:40:00 20.5 1.9 24.4 15.3 20.6 2 24.4 15.3 19.9 2.2 24.8 13.3 147 5 148 165 2.3 0 2.6 2.3 02/05/2006 20:50:00 18.5 1.3 21.8 15.3 18.6 1.3 22.1 15.6 18.4 1.5 22.1 13.7 147 6 149 165 2.3 0 2.6 2.3 02/05/2006 21:00:00 19.8 1.3 22.9 16.1 19.8 1.3 22.9 16.4 19.4 1.6 22.9 14.1 148 6 139 165 2.1 0.1 2.3 1.8 02/05/2006 21:10:00 16.6 1.1 19.5 13 16.7 1.2 19.9 13.3 16.2 1.3 19.5 12.6 146 5 146 165 2.3 0 2.3 2.1 02/05/2006 21:20:00 18.9 1.4 22.6 15.3 19 1.5 22.1 15.3 18.6 1.5 21.8 14.9 149 4 153 165 2.4 0 2.6 2.3 02/05/2006 21:30:00 18.3 1.3 21.4 14.1 18.5 1.3 21.8 14.1 18 1.3 21.8 13.3 145 5 150 165 2.5 0 2.8 2.3 02/05/2006 21:40:00 17.1 1.7 21 13 17.2 1.7 21 13.3 17.1 1.7 21.8 13.3 145 5 139 165 2.7 0 2.8 2.6 02/05/2006 21:50:00 16.2 1.4 20.2 13 16.3 1.4 20.2 13 15.9 1.5 19.9 12.2 141 6 139 165 2.7 0 2.8 2.6 02/05/2006 22:00:00 17.2 1.5 21.4 13.3 17.2 1.5 21.4 13.3 16.9 1.7 21 11.5 142 6 136 165 2.7 0 2.8 2.6 02/05/2006 22:10:00 15.7 1.1 18.3 12.6 15.7 1.1 18.3 12.6 15.5 1.3 18.3 10.7 140 5 145 165 2.6 0 2.8 2.6 02/05/2006 22:20:00 13.9 1.5 18.3 9.9 14 1.5 17.9 9.9 13.8 1.6 17.9 9.9 137 7 138 165 2.7 0 2.8 2.6 02/05/2006 22:30:00 14.9 1.4 17.6 10.7 15 1.3 17.6 11.1 14.9 1.5 18.3 9.9 139 6 141 165 2.9 0 3 2.8 02/05/2006 22:40:00 17.3 2.1 22.1 13.7 17.3 2.1 22.1 13 17.2 2.3 22.9 11.5 146 6 148 165 2.4 0.4 3 1.8 02/05/2006 22:50:00 13.5 1.3 17.9 9.1 13.6 1.3 17.2 9.9 12.9 1.3 16.4 9.9 135 9 118 165 2.3 0.2 2.6 1.8 02/05/2006 23:00:00 15.8 1.7 19.5 11.8 16.1 1.7 19.9 11.8 15.4 1.7 19.5 10.7 126 8 110 165 2.6 0 2.8 2.6 02/05/2006 23:10:00 17.4 1.7 21.8 12.2 17.7 1.7 22.1 11.8 17.1 1.7 21.4 11.5 124 7 126 165 2.9 0.1 3 2.8 02/05/2006 23:20:00 18.7 1.5 24 14.9 19 1.6 24 15.6 18.4 1.7 23.7 13.7 133 7 123 165 3 0 3.3 2.8 02/05/2006 23:30:00 18.6 2.4 24 13.7 18.5 2.3 23.7 13.7 18.5 2.4 23.7 13.3 144 5 145 165 2 0.5 3 1.4 02/05/2006 23:40:00 15.3 1 18.7 12.6 15.3 1.1 18.7 12.2 14.9 1.1 17.6 10.7 142 7 139 165 1.7 0 1.8 1.6 02/05/2006 23:50:00 12.8 1 16.1 9.9 12.7 1 15.6 9.9 12.5 1 15.3 9.9 148 5 146 165 1.7 0 1.8 1.6 02/06/2006 00:00:00 13.4 0.7 14.9 10.7 13.4 0.7 14.9 10.7 13.4 0.9 15.3 10.3 146 4 148 165 1.8 0 1.8 1.6 02/06/2006 00:10:00 12.7 0.8 14.5 9.9 12.6 0.8 14.1 9.9 12.6 1.1 14.9 8.4 147 5 145 165 1.8 0 1.8 1.8 02/06/2006 00:20:00 13.7 1.8 17.6 9.9 13.7 1.7 17.6 9.9 13.6 1.8 17.9 9.5 146 6 154 165 1.9 0 2.1 1.8 02/06/2006 00:30:00 14.1 1.1 17.9 11.5 14.1 1.1 17.2 11.8 13.9 1.1 16.4 10.7 146 7 128 165 1.8 0.1 1.8 1.6 02/06/2006 00:40:00 14.4 1.2 16.4 11.1 14.5 1.2 16.8 11.1 14.4 1.2 16.8 10.3 145 3 142 165 1.9 0 1.8 1.8 02/06/2006 00:50:00 12 0.8 13.7 10.3 12.1 0.8 14.1 10.3 12 0.9 14.1 9.1 145 4 139 165 1.9 0 1.8 1.8 02/06/2006 01:00:00 10.9 0.9 12.6 8.4 10.9 0.9 13 8.8 10.5 1 12.6 8 145 4 143 165 1.9 0 2.1 1.8 02/06/2006 01:10:00 11.2 0.9 13.3 8.8 11.2 0.9 13.3 8.8 11 1 13.3 8 145 5 150 165 1.9 0 2.1 1.8 02/06/2006 01:20:00 10.7 0.6 12.2 9.1 10.7 0.6 12.2 9.1 10.5 0.8 12.2 7.2 147 4 145 165 2 0 2.1 1.8 02/06/2006 01:30:00 10.4 0.5 11.8 8.8 10.4 0.5 11.8 8.8 10.2 0.7 11.8 8 145 5 135 165 2 0 2.1 1.8 02/06/2006 01:40:00 9.1 0.6 11.1 8 9.1 0.6 11.1 7.6 9.1 0.7 11.1 6.1 150 3 149 165 2 0 2.1 1.8 02/06/2006 01:50:00 8.1 0.5 9.1 6.8 8.1 0.5 9.1 6.5 7.9 0.7 9.5 6.5 147 3 141 165 2 0 2.1 1.8 02/06/2006 02:00:00 7.5 0.5 8.8 6.1 7.5 0.5 8.8 6.1 7.5 0.5 8.8 6.1 147 4 142 165 2 0 2.1 1.8 02/06/2006 02:10:00 6.6 0.9 8.4 4.6 6.6 0.9 8.4 4.6 6.5 0.9 8 4.6 145 3 146 165 2 0 2.1 1.8 02/06/2006 02:20:00 4.9 0.4 6.1 3.8 4.9 0.4 6.1 3.8 4.7 0.5 6.1 3.4 145 5 145 165 2 0 2.3 1.8 02/06/2006 02:30:00 6.9 1.8 11.1 4.2 6.9 1.8 10.7 4.6 6.5 1.8 10.3 3.4 139 6 138 165 2.1 0 2.3 1.8 02/06/2006 02:40:00 9 1.1 12.6 6.8 9 1.1 13 6.5 8.7 1.1 12.6 6.1 138 8 132 165 2.4 0 2.6 2.3 02/06/2006 02:50:00 10.3 1.2 13.3 6.1 10.2 1.3 13.3 5.7 10.2 1.2 13.3 7.2 148 17 133 165 2.3 0.3 2.6 1.4 02/06/2006 03:00:00 8 1 10.7 5.7 7.8 0.9 10.3 5.7 7.8 1.2 11.1 4.6 152 14 150 165 1.9 0.1 2.1 1.6 02/06/2006 03:10:00 6.8 1.2 10.7 3.4 6.7 1.2 10.3 3.4 6.5 1.2 9.9 3.8 156 13 157 165 1.8 0 2.1 1.4 02/06/2006 03:20:00 8.4 1.1 11.5 6.1 8.3 1.1 11.5 6.1 8.2 1 10.7 6.1 141 9 128 165 2 0 2.3 1.8 02/06/2006 03:30:00 9 0.9 10.7 6.8 9 0.9 10.7 6.8 8.9 0.9 10.7 6.5 144 5 145 165 2.1 0 2.3 1.8 02/06/2006 03:40:00 9.3 0.9 11.8 7.2 9.3 0.9 11.8 7.2 9.1 1 11.5 6.1 142 6 139 165 2.3 0 2.6 2.3 02/06/2006 03:50:00 9.3 0.7 11.1 7.6 9.3 0.7 11.1 7.2 9.2 0.8 11.1 7.2 144 5 145 165 2.3 0 2.6 2.3 02/06/2006 04:00:00 9.9 0.5 10.7 8.4 9.8 0.5 10.7 8 9.9 0.7 11.1 7.6 142 4 145 165 2.4 0 2.6 2.3 02/06/2006 04:10:00 9.6 0.5 10.7 8 9.6 0.5 11.1 8 9.4 0.7 10.7 6.8 143 4 145 165 2.1 0 2.3 2.1 02/06/2006 04:20:00 9.1 0.4 9.9 8 9 0.4 9.9 8 8.9 0.5 10.3 7.6 148 4 142 165 2.1 0 2.3 2.1 02/06/2006 04:30:00 8.5 0.5 9.5 7.2 8.5 0.5 9.5 7.2 8.1 0.6 9.5 6.1 146 3 154 165 2.1 0 2.3 2.1 02/06/2006 04:40:00 7.3 0.5 8 6.1 7.2 0.4 8 6.1 7.1 0.4 8 6.1 145 3 150 165 2.1 0 2.3 2.1 02/06/2006 04:50:00 6.3 0.4 7.2 4.9 6.2 0.5 7.2 4.9 6.1 0.4 7.2 4.9 152 10 139 165 2.2 0 2.6 2.1 02/06/2006 05:00:00 6.2 0.6 7.6 4.6 6.1 0.6 7.6 4.6 6.3 0.7 8.4 4.6 183 13 185 165 2.1 0.1 2.6 1.8 02/06/2006 05:10:00 5.7 0.5 6.8 4.2 5.8 0.6 6.8 3.8 5.8 0.6 7.2 4.2 200 4 200 165 1.7 0 1.8 1.6 02/06/2006 05:20:00 5.2 0.7 6.5 3.4 5.2 0.7 6.5 3.4 5.3 0.8 6.8 3 195 5 196 165 1.7 0 1.8 1.6 02/06/2006 05:30:00 4.5 0.9 6.8 2.3 4.5 1 6.8 2.3 4.2 0.8 6.5 2.3 213 11 219 165 1.7 0 1.8 1.6 02/06/2006 05:40:00 4.7 0.5 5.7 2.6 4.8 0.5 6.1 3 4.3 0.7 5.7 2.3 226 0 227 165 1.7 0 1.8 1.6 02/06/2006 05:50:00 5 0.8 7.6 3 5.1 0.8 7.2 2.6 4.4 0.9 6.8 2.6 224 3 234 165 1.7 0 1.8 1.6 02/06/2006 06:00:00 5.2 0.9 7.6 3 5.3 0.9 7.6 3 4.8 0.8 6.8 3 222 5 219 165 1.7 0 1.8 1.6 02/06/2006 06:10:00 7.8 0.6 9.5 5.7 7.9 0.6 9.5 5.7 7.2 1 9.1 4.6 219 5 218 165 1.7 0 1.8 1.6 02/06/2006 06:20:00 6 0.9 8 3.4 6.1 0.8 8 3.4 5.8 0.9 7.6 3.4 218 6 228 165 1.7 0 1.8 1.6 02/06/2006 06:30:00 3.7 1.3 6.5 0.4 3.8 1.3 6.5 0.4 3.3 1.5 6.5 0.4 216 5 215 165 1.7 0 1.8 1.6 02/06/2006 06:40:00 5.2 1 6.8 2.6 5.2 1 6.8 2.6 5.2 1.1 6.8 2.3 199 4 197 165 1.7 0 1.8 1.6 02/06/2006 06:50:00 3 0.8 5.3 1.5 3.1 0.8 5.3 1.5 2.7 0.9 4.9 0.7 201 7 214 165 1.5 0 1.6 1.4 02/06/2006 07:00:00 2.7 0.8 4.9 1.1 2.9 0.7 4.9 1.5 2.6 0.8 4.9 0.7 237 16 215 165 1.5 0 1.6 1.4 02/06/2006 07:10:00 4 1 6.8 1.5 4.1 1 6.5 1.5 3.1 0.9 4.9 0.7 286 8 297 165 1.7 0 1.8 1.4 02/06/2006 07:20:00 3.7 0.8 5.7 1.1 4.3 0.7 6.5 2.6 4.1 0.6 6.1 2.6 270 5 276 165 1.7 0 1.8 1.6 02/06/2006 07:30:00 5.1 2.1 9.5 1.5 5.3 1.9 9.5 2.6 4.4 1.4 8 1.9 286 14 308 165 1.8 0 1.8 1.6 02/06/2006 07:40:00 7.1 1.3 10.7 4.6 7 1.3 10.7 4.2 6 1.3 10.3 3.4 306 8 321 165 1.8 0 1.8 1.6 02/06/2006 07:50:00 8.4 1 11.5 6.5 8.3 1 11.5 6.1 6.5 1.1 11.5 4.2 298 6 292 165 1.9 0 1.8 1.8 02/06/2006 08:00:00 9.9 1.2 13 6.5 9.9 1.2 13.3 6.8 7.9 1.6 13.7 4.9 292 6 281 165 1.9 0 2.1 1.8 02/06/2006 08:10:00 9.9 1.1 12.6 6.5 9.9 1.1 13 6.1 7.7 1.4 13 4.9 292 6 280 165 1.8 0 1.8 1.8 02/06/2006 08:20:00 8.2 1.3 11.5 4.9 8.5 1.2 11.8 5.7 7.5 1 9.9 5.3 282 8 301 165 1.7 0 1.8 1.6 02/06/2006 08:30:00 9.1 1 11.8 6.8 9.2 1 11.8 6.8 8.1 1.1 11.5 4.9 285 7 274 165 1.6 0 1.6 1.6 02/06/2006 08:40:00 8.8 1.2 12.2 5.3 8.8 1.2 11.8 5.7 7.3 1.5 11.5 3.8 289 6 287 165 1.6 0 1.8 1.6 02/06/2006 08:50:00 8.5 1 11.1 6.5 8.6 1 11.1 6.5 7.5 1.3 11.1 3.8 285 4 282 165 1.6 0 1.8 1.6 02/06/2006 09:00:00 6.4 1.1 9.1 3.4 7.2 1 9.5 4.2 6.6 1 9.5 3.8 274 9 281 165 1.6 0 1.8 1.4 02/06/2006 09:10:00 4 1 6.8 1.1 4.6 1.3 8 1.5 4.4 1.2 7.6 1.9 246 13 268 165 1.6 0 1.8 1.4 02/06/2006 09:20:00 3.6 0.7 6.1 1.1 3.7 0.6 5.7 1.9 3.6 0.5 4.9 1.9 241 5 241 165 1.4 0 1.6 1.4 02/06/2006 09:30:00 4.7 0.6 6.5 3 4.6 0.6 6.1 3.4 4.5 0.6 6.1 2.6 240 5 239 165 1.5 0 1.6 1.4 02/06/2006 09:40:00 4.5 0.7 6.5 3 4.6 0.8 6.8 3 4.4 0.7 6.8 2.6 227 13 205 165 1.5 0 1.6 1.4 02/06/2006 09:50:00 6.1 1.4 9.9 3 6.1 1.3 9.9 3.4 5.9 1.5 9.9 1.9 203 11 198 165 1.4 0 1.6 1.4 02/06/2006 10:00:00 8.5 0.9 10.3 5.7 8.5 0.8 10.3 5.7 8.4 1 10.3 5.3 198 5 203 165 1.4 0 1.4 1.4 02/06/2006 10:10:00 6.6 0.7 8.8 4.6 6.7 0.7 8.4 4.6 6.3 0.8 8.8 4.2 209 5 207 165 1.4 0 1.6 1.4 02/06/2006 10:20:00 6.4 0.8 8.8 4.2 6.4 0.8 8.4 3.8 6 0.8 7.6 3.8 209 5 217 165 1.4 0 1.6 1.4 02/06/2006 10:30:00 7.4 1 9.9 4.2 7.5 1 9.9 3.8 7.1 1.1 9.9 4.6 214 6 204 165 1.4 0 1.8 1.4 02/06/2006 10:40:00 7.1 0.8 9.5 4.6 7.2 0.9 9.5 4.6 6.8 1 9.9 4.2 212 7 214 165 1.8 0.1 2.3 1.6 02/06/2006 10:50:00 7.5 1 9.9 3.4 7.5 1 9.9 3 7.4 1 9.9 3.8 204 8 206 165 2.6 0 2.8 2.1 02/06/2006 11:00:00 8.4 1.2 11.8 5.7 8.4 1.2 11.8 5.3 8.4 1.3 11.8 4.9 202 8 203 165 2.6 0.1 2.8 2.6 02/06/2006 11:10:00 7.3 1 10.3 3.8 7.3 1 10.3 3.4 7 1.1 9.5 3.8 206 8 196 165 2.7 0 2.8 2.6 02/06/2006 11:20:00 6.1 1.7 10.3 2.3 6.1 1.7 9.9 1.9 6 1.6 10.7 3 205 11 210 165 2.6 0.1 3 2.3 02/06/2006 11:30:00 5.5 1.4 9.9 2.3 5.5 1.5 9.9 1.9 5.6 1.3 9.9 1.5 185 15 182 165 3 0 3.3 2.8 02/06/2006 11:40:00 6 1.2 8.8 2.6 6 1.2 8.8 3 6.3 1.2 9.1 3.4 192 12 194 165 2.7 0 2.8 2.6 02/06/2006 11:50:00 5.1 1.2 8.4 2.6 5.1 1.2 8.8 2.6 5.2 1 7.6 2.6 194 20 198 165 2.9 0.1 3.3 2.6 02/06/2006 12:00:00 7.7 1.9 13 3.4 7.8 2 13 3.8 7.8 1.7 12.6 4.2 206 12 194 165 2.4 0.1 2.8 2.3 02/06/2006 12:10:00 10.7 1.2 15.3 7.6 10.9 1.2 14.9 8 10.6 1.3 15.3 7.6 205 9 199 165 2 0.1 2.6 1.8 02/06/2006 12:20:00 12.2 1.7 16.4 8 12.2 1.7 16.8 8 12.4 1.6 16.8 8.4 198 9 204 165 1.8 0 2.1 1.6 02/06/2006 12:30:00 12.2 1.8 15.3 6.8 12.2 1.8 15.6 6.8 12.1 2.1 16.4 7.2 198 8 210 165 1.7 0 1.8 1.4 02/06/2006 12:40:00 10.6 1.6 14.1 6.1 10.7 1.6 14.1 6.1 10.6 1.8 14.5 6.5 196 9 205 165 1.8 0 2.1 1.6 02/06/2006 12:50:00 9.3 1.7 14.5 5.3 9.4 1.7 14.5 6.1 9.3 1.7 14.9 6.5 204 12 192 165 2 0 2.3 1.6 02/06/2006 13:00:00 9.6 1.5 13.7 5.7 9.8 1.5 13.7 5.7 9.8 1.6 14.5 4.9 199 10 189 165 1.8 0.1 2.3 1.4 02/06/2006 13:10:00 11.7 1.8 17.6 8 11.6 1.7 16.8 8 12 1.8 17.9 8 185 9 182 165 1.7 0.1 1.8 1.4 02/06/2006 13:20:00 13.7 1.2 17.9 10.3 13.5 1.2 17.6 9.9 14.1 1.3 17.2 9.9 184 8 186 165 1.7 0 1.8 1.6 02/06/2006 13:30:00 13.7 1.6 17.6 9.5 13.5 1.5 17.2 9.1 13.9 1.6 17.9 9.9 185 7 181 165 1.6 0 1.8 1.6 02/06/2006 13:40:00 11.2 1.3 14.5 8.4 11.1 1.2 14.1 8.4 11.4 1.3 14.9 8 188 11 182 165 1.8 0 1.8 1.6 02/06/2006 13:50:00 9.9 1.2 13.3 6.8 9.8 1.2 12.6 6.5 10.2 1.2 14.1 7.6 185 10 189 165 2 0.1 2.3 1.6 02/06/2006 14:00:00 10.3 1.3 14.5 7.2 10.2 1.2 14.1 7.2 10.5 1.2 13.7 8 186 9 186 165 1.9 0 2.1 1.8 02/06/2006 14:10:00 10.7 1.7 16.1 5.7 10.7 1.6 16.1 6.5 11 1.5 16.8 6.8 189 8 191 165 1.9 0 1.8 1.6 02/06/2006 14:20:00 10.8 1.3 14.1 6.5 10.9 1.3 14.1 6.5 11.1 1.5 14.9 6.1 196 8 197 165 1.8 0 1.8 1.6 02/06/2006 14:30:00 8 1.2 11.1 4.6 8.2 1.2 11.1 4.9 8 1.3 12.2 4.9 198 12 204 165 2.1 0 2.3 1.8 02/06/2006 14:40:00 8.1 1.1 11.1 5.3 8.2 1.1 11.1 5.3 8.5 1.2 11.8 5.3 194 11 204 165 2 0 2.3 1.8 02/06/2006 14:50:00 8.8 1 11.5 6.1 8.8 0.9 11.1 6.5 9.1 1 11.8 6.8 184 8 183 165 1.9 0 2.1 1.6 02/06/2006 15:00:00 8.4 1.2 11.5 5.3 8.4 1.1 11.1 5.7 8.7 1.2 11.8 5.7 191 8 190 165 0.9 0.3 1.6 0.7 02/06/2006 15:10:00 9.4 1.2 13 6.1 9.3 1.2 12.6 5.7 9.2 1.1 12.6 6.5 190 8 199 165 0.5 0 0.7 0.2 02/06/2006 15:20:00 10.7 0.7 12.6 8.4 10.7 0.7 13 8.4 10.9 0.8 13 8 195 5 199 165 0.1 0 0.4 -0.1 02/06/2006 15:30:00 9.9 0.8 11.8 6.8 9.8 0.8 11.5 7.2 10.1 0.8 11.8 7.2 192 5 192 165 -0.2 0.1 -0.1 -0.5 02/06/2006 15:40:00 9.7 1.1 12.6 6.5 9.6 1.1 12.2 6.5 9.8 1.1 12.2 7.2 187 8 194 165 -0.5 0 -0.3 -0.8 02/06/2006 15:50:00 10.6 1.2 13.7 7.6 10.3 1.2 13.3 7.6 10.9 1.2 14.1 8 179 13 196 165 -0.4 0.1 -0.3 -0.8 02/06/2006 16:00:00 9.6 0.7 11.8 7.6 9.3 0.7 11.5 7.2 10 0.7 12.2 8 172 9 180 165 -0.5 0.1 -0.3 -0.8 02/06/2006 16:10:00 9.3 0.6 10.7 6.8 9 0.6 10.3 6.8 9.5 0.6 11.1 7.2 171 10 175 165 -1 0 -0.8 -1.2 02/06/2006 16:20:00 8.9 0.5 10.3 7.6 8.7 0.5 9.9 7.2 9 0.6 10.7 7.2 168 9 173 165 -1.2 0 -1.2 -1.4 02/06/2006 16:30:00 7 1.1 9.1 4.2 6.9 1.1 9.1 4.2 7.1 1.2 9.5 4.2 169 12 167 165 -1 0 -0.8 -1.4 02/06/2006 16:40:00 3.6 1.6 7.2 0.4 3.8 1.4 7.2 0.7 3.7 1.3 7.2 1.1 199 13 189 165 -1.2 0.1 -0.8 -1.4 02/06/2006 16:50:00 4.5 1.5 7.6 0.7 4.6 1.3 7.6 0.7 4.5 1.2 7.2 1.1 202 27 207 165 -1.2 0 -1 -1.4 02/06/2006 17:00:00 3.3 1.1 6.1 0.4 3.5 1.1 6.8 0.7 3.3 1 5.7 1.1 220 22 230 165 -1 0.1 -0.8 -1.2 02/06/2006 17:10:00 3.9 0.7 5.7 1.9 4.2 0.7 6.1 2.3 4 0.6 6.1 2.6 214 10 225 165 -0.8 0 -0.5 -1 02/06/2006 17:20:00 3.7 0.7 6.1 2.3 3.8 0.7 6.1 2.3 3.7 0.8 5.7 1.1 203 13 217 165 -0.6 0 -0.5 -0.8 02/06/2006 17:30:00 4.2 0.7 5.7 2.6 4.2 0.6 5.7 2.6 4.4 0.7 6.1 3 178 10 185 165 -0.7 0 -0.5 -0.8 02/06/2006 17:40:00 4.2 0.7 6.1 2.6 4.2 0.7 6.1 2.6 4.3 0.6 5.7 2.6 183 9 191 165 -0.9 0 -0.5 -1 02/06/2006 17:50:00 3.5 0.7 5.7 2.3 3.6 0.6 5.7 2.3 3.5 0.7 5.7 2.3 203 10 194 165 -0.8 0 -0.5 -0.8 02/06/2006 18:00:00 2.9 1.1 4.9 0.4 3 1.1 5.3 0.4 2.7 1.1 4.9 0.4 212 13 208 165 -0.9 0 -0.8 -1 02/06/2006 18:10:00 5.1 0.9 7.2 3 5.1 0.8 6.8 3 5 1 7.2 3 192 7 189 165 -0.8 0 -0.5 -1.2 02/06/2006 18:20:00 4 0.8 6.1 2.6 4.1 0.7 6.1 2.6 4 0.8 5.7 1.9 196 7 189 165 -0.6 0 -0.5 -0.8 02/06/2006 18:30:00 4.1 1.5 7.6 2.3 4.1 1.5 7.6 2.6 4.1 1.4 7.2 2.3 196 6 203 165 -0.8 0 -0.5 -0.8 02/06/2006 18:40:00 5.6 1 8.8 3 5.5 1 8.8 3.4 5.4 1 9.5 3.4 176 12 163 165 -0.6 0 -0.3 -0.8 02/06/2006 18:50:00 4.6 0.6 6.5 3.4 4.6 0.6 6.5 3.4 4.6 0.6 6.1 3 177 10 181 165 -0.8 0.1 -0.5 -0.8 02/06/2006 19:00:00 5.7 1 7.6 3.4 5.7 1 7.6 3.4 5.6 1.1 8 3.4 190 8 203 165 -0.8 0 -0.5 -0.8 02/06/2006 19:10:00 5.3 0.7 7.2 3.8 5.3 0.6 7.2 4.2 5.3 0.8 6.8 3.4 187 5 178 165 -0.8 0 -0.8 -1 02/06/2006 19:20:00 5 0.9 7.2 3.4 5 0.8 6.8 3.8 5 0.8 7.2 3.8 179 8 179 165 -0.9 0 -0.8 -1.2 02/06/2006 19:30:00 6.4 0.6 7.6 4.6 6.3 0.5 7.6 4.9 6.4 0.6 8 4.6 175 8 174 165 -0.9 0 -0.8 -1.2 02/06/2006 19:40:00 7.3 1.2 9.9 4.6 7.2 1.2 9.9 4.6 7.2 1.2 11.1 4.9 179 10 185 165 -0.9 0.1 -0.5 -1.2 02/06/2006 19:50:00 7.4 1.1 9.9 4.2 7.4 1.1 9.9 4.2 7.5 1 10.3 5.3 191 8 197 165 -0.8 0.1 -0.5 -1 02/06/2006 20:00:00 8.4 0.8 11.1 6.5 8.5 0.8 10.7 6.5 8.4 0.9 10.7 5.3 190 7 196 165 -0.9 0 -0.8 -1 02/06/2006 20:10:00 7.9 0.7 9.9 5.7 8 0.7 9.9 6.1 8 0.8 9.9 6.1 196 5 197 165 -1 0 -0.8 -1.2 02/06/2006 20:20:00 8.5 0.5 9.5 6.8 8.6 0.5 9.9 6.8 8.7 0.7 10.3 6.5 195 4 196 165 -1 0 -0.8 -1.2 02/06/2006 20:30:00 8 0.6 9.1 6.1 8.1 0.6 9.1 6.5 8.1 0.7 9.5 5.7 194 4 194 165 -1 0 -0.8 -1.2 02/06/2006 20:40:00 8 0.5 9.1 6.5 8.1 0.4 9.1 6.5 8.2 0.6 9.5 6.1 191 4 186 165 -1.1 0 -1 -1.2 02/06/2006 20:50:00 7.2 0.6 8.4 5.3 7.2 0.6 8.4 5.3 7.1 0.7 8.4 4.9 189 6 177 165 -1 0 -1 -1.2 02/06/2006 21:00:00 7 0.5 8.4 5.3 7 0.5 8.8 5.3 7.1 0.6 8.4 4.9 187 5 188 165 -1.1 0 -1 -1.2 02/06/2006 21:10:00 7.6 0.6 8.8 5.3 7.7 0.6 8.8 5.7 7.7 0.8 9.5 5.7 192 6 191 165 -1.2 0 -1.2 -1.4 02/06/2006 21:20:00 8.6 1 11.1 6.5 8.7 1 11.1 6.1 8.6 1 11.1 6.5 195 6 204 165 -1.3 0.1 -1.2 -1.4 02/06/2006 21:30:00 10.1 1.1 13.3 7.2 10 1.1 13 6.8 10.1 1.2 14.1 7.2 185 8 185 165 -1.4 0 -1.4 -1.7 02/06/2006 21:40:00 9.3 1 11.8 5.7 9.1 0.9 11.5 5.7 9.5 1 12.2 6.8 176 8 170 165 -1.5 0 -1.4 -1.7 02/06/2006 21:50:00 8.5 1 11.1 6.1 8.3 0.9 10.3 6.1 8.6 0.9 10.7 5.7 183 7 193 165 -1.6 0 -1.4 -1.9 02/06/2006 22:00:00 8.1 0.6 9.5 6.1 7.9 0.5 9.1 6.1 8.3 0.5 9.5 6.8 181 5 183 165 -1.8 0 -1.7 -1.9 02/06/2006 22:10:00 8.6 0.8 10.7 6.1 8.4 0.7 10.3 6.5 8.6 0.7 10.3 6.8 182 5 178 165 -2 0 -1.9 -2.1 02/06/2006 22:20:00 9.3 0.7 12.2 8 9.1 0.6 11.8 7.6 9.3 0.7 11.1 7.6 180 5 176 165 -1.7 0 -1.4 -1.9 02/06/2006 22:30:00 8.2 0.7 9.9 5.7 8 0.6 9.5 5.7 8.3 0.6 9.5 6.1 182 6 185 165 -1.6 0 -1.4 -1.7 02/06/2006 22:40:00 8.6 0.7 10.3 6.1 8.6 0.7 10.7 6.1 8.5 0.8 11.1 6.1 191 6 193 165 -1.6 0 -1.4 -1.9 02/06/2006 22:50:00 8.2 1 10.3 6.1 8.2 1 10.3 6.1 8.2 1 10.3 5.7 186 9 177 165 -1.6 0 -1.4 -1.7 02/06/2006 23:00:00 8.2 1.1 11.1 5.7 8.1 1.1 11.1 5.7 8.2 1 11.1 5.7 183 8 188 165 -1.3 0 -1.2 -1.7 02/06/2006 23:10:00 7.3 0.6 8.4 5.7 7.3 0.6 8.4 5.7 7.3 0.7 8.8 5.7 190 4 191 165 -1.4 0 -1.2 -1.4 02/06/2006 23:20:00 7.2 0.6 9.1 5.7 7.1 0.7 9.1 5.3 7.4 0.7 9.1 5.7 187 6 191 165 -1.4 0 -1.4 -1.4 02/06/2006 23:30:00 7.1 0.7 8.8 5.3 7 0.7 8.8 5.3 7.1 0.8 9.1 4.9 181 6 181 165 -1.3 0 -1.2 -1.4 02/06/2006 23:40:00 5.9 1 8 3.4 5.9 1 7.6 3.4 5.8 1 8 3.8 190 8 199 165 -1.3 0 -1.2 -1.4 02/06/2006 23:50:00 6.4 0.8 8.8 4.6 6.4 0.7 8.4 4.6 6.4 0.8 8.8 4.9 192 6 201 165 -1.3 0 -1.2 -1.4 02/07/2006 00:00:00 6.1 0.7 7.6 4.2 6 0.6 7.6 4.2 6.1 0.8 8 4.2 184 7 182 165 -1.2 0 -1.2 -1.4 02/07/2006 00:10:00 4.1 0.5 5.3 3 4.1 0.5 5.3 3 4.2 0.5 5.7 3 180 7 191 165 -1.4 0 -1.2 -1.4 02/07/2006 00:20:00 4.1 0.7 6.5 1.9 4.2 0.7 6.5 2.3 4.1 0.8 6.8 2.3 194 10 195 165 -1.4 0 -1.2 -1.4 02/07/2006 00:30:00 3 0.8 4.9 0.7 3.2 0.7 5.3 1.1 2.9 0.9 5.3 1.1 201 11 181 165 -1.5 0 -1.2 -1.7 02/07/2006 00:40:00 3.7 0.5 4.9 2.3 3.8 0.5 4.9 2.6 3.8 0.5 4.9 2.6 189 5 189 165 -1.5 0 -1.4 -1.7 02/07/2006 00:50:00 3.8 0.4 4.6 2.6 3.8 0.4 4.9 2.6 3.7 0.4 4.6 3 179 5 179 165 -1.6 0 -1.4 -1.7 02/07/2006 01:00:00 4.2 0.4 4.9 3.4 4.2 0.3 4.9 3 4.3 0.4 4.9 3.4 182 5 183 165 -1.6 0 -1.4 -1.7 02/07/2006 01:10:00 4.3 0.3 4.9 3.4 4.4 0.3 4.9 3.4 4.5 0.3 5.3 3.8 200 5 190 165 -1.6 0 -1.4 -1.7 02/07/2006 01:20:00 4.9 0.7 7.2 3.8 5 0.6 6.8 3.8 5.2 0.7 7.2 3.8 202 4 196 165 -1.5 0 -1.4 -1.7 02/07/2006 01:30:00 6.6 0.8 8.4 4.9 6.6 0.8 8 4.9 6.8 1 8.8 4.2 192 9 178 165 -1.5 0 -1.4 -1.7 02/07/2006 01:40:00 2.9 1 6.1 0.4 3.2 0.9 5.7 0.7 3 1 5.7 0.4 256 22 303 165 -1.7 0 -1.4 -1.9 02/07/2006 01:50:00 3.4 0.8 5.7 1.9 3.5 0.7 5.3 2.3 3.7 0.7 5.3 2.3 215 15 199 165 -1.7 0 -1.4 -2.1 02/07/2006 02:00:00 4.3 1.1 6.5 1.9 4.3 1.1 6.8 1.9 4.3 1.1 6.8 1.9 196 8 189 165 -1.5 0 -1.4 -1.7 02/07/2006 02:10:00 6 0.8 7.2 4.2 6.1 0.8 7.6 4.2 6 0.8 7.6 3.8 201 7 210 165 -1.7 0 -1.4 -1.9 02/07/2006 02:20:00 6 0.9 8 3 6.1 0.9 8 3.4 5.7 1.1 8 3 202 7 203 165 -1.7 0 -1.4 -1.9 02/07/2006 02:30:00 6.5 0.5 7.6 5.7 6.7 0.5 8 5.7 6.4 0.6 8 4.6 202 3 197 165 -1.7 0 -1.7 -1.9 02/07/2006 02:40:00 5.6 0.5 6.8 4.6 5.7 0.5 6.8 4.6 5.7 0.6 7.6 3.8 197 6 201 165 -1.8 0 -1.7 -1.9 02/07/2006 02:50:00 5.1 0.6 6.5 3.4 5.2 0.5 6.5 3.4 5.1 0.6 6.5 3.4 195 8 195 165 -1.8 0 -1.7 -1.9 02/07/2006 03:00:00 3.9 0.9 5.7 1.5 4 0.8 5.3 1.9 4 1 5.7 1.9 188 7 187 165 -1.8 0 -1.7 -2.1 02/07/2006 03:10:00 2.7 0.5 3.8 1.5 2.8 0.4 3.8 1.5 2.8 0.4 3.8 1.9 184 9 188 165 -1.8 0 -1.7 -2.1 02/07/2006 03:20:00 2.5 0.4 3.4 1.1 2.7 0.4 3.4 1.5 2.6 0.4 3.4 1.5 175 8 165 165 -1.8 0 -1.7 -1.9 02/07/2006 03:30:00 1 0.8 2.6 0.4 1.4 0.6 3 0.4 1.2 0.8 3 0.4 178 6 185 165 -1.8 0 -1.7 -1.9 02/07/2006 03:40:00 1 0.7 3.4 0.4 1.6 0.7 3.8 0.4 1 0.6 2.3 0.4 251 39 289 165 -1.8 0.1 -1.4 -1.9 02/07/2006 03:50:00 2.5 0.6 3.8 1.5 3.2 0.7 4.2 1.9 2.8 0.7 4.2 1.1 269 8 266 165 -1.3 0 -1 -1.4 02/07/2006 04:00:00 2.5 0.6 4.2 0.7 3.4 0.5 4.6 2.3 3.1 0.5 4.6 1.9 260 6 271 165 -1 0 -0.8 -1.2 02/07/2006 04:10:00 2.5 0.6 3.8 0.7 3.5 0.4 4.6 2.6 3.2 0.4 4.2 2.3 261 5 265 165 -1 0 -0.8 -1.2 02/07/2006 04:20:00 2.9 0.6 4.2 0.7 3.4 0.4 4.2 2.6 3.2 0.4 4.2 2.3 268 9 281 165 -1 0 -0.8 -1.2 02/07/2006 04:30:00 2.2 0.6 3.8 1.1 2.6 0.4 3.8 1.9 2.4 0.3 3.4 1.9 268 9 277 165 -1.1 0 -1 -1.2 02/07/2006 04:40:00 1.6 0.4 2.6 0.4 2.2 0.3 3 1.5 2 0.2 2.6 1.5 260 6 272 165 -0.9 0 -0.8 -1.2 02/07/2006 04:50:00 1.2 0.5 2.3 0.4 1.3 0.5 2.3 0.4 1.1 0.5 2.3 0.4 273 8 272 165 -0.8 0 -0.8 -0.8 02/07/2006 05:00:00 0.5 0.3 1.5 0.4 0.6 0.3 1.5 0.4 0.4 0.2 1.1 0.4 289 11 295 165 -1.1 0 -0.8 -1.2 02/07/2006 05:10:00 0.5 0.4 1.5 0.4 0.6 0.4 1.5 0.4 0.5 0.4 1.5 0.4 231 18 211 165 -1.3 0.1 -1 -1.4 02/07/2006 05:20:00 0.8 0.5 1.9 0.4 0.8 0.5 1.9 0.4 0.9 0.5 1.9 0.4 206 10 211 165 -1.3 0 -1.2 -1.4 02/07/2006 05:30:00 1.2 0.5 2.3 0.4 1.5 0.5 2.3 0.4 1.1 0.6 2.3 0.4 262 23 234 165 -1.1 0 -0.8 -1.2 02/07/2006 05:40:00 0.4 0.1 1.1 0.4 0.4 0.2 1.1 0.4 0.5 0.3 1.9 0.4 324 17 331 165 -1.4 0.1 -1.2 -1.7 02/07/2006 05:50:00 1.3 0.5 2.3 0.4 1.4 0.5 2.6 0.4 1.1 0.6 2.6 0.4 320 6 330 165 -1.7 0 -1.4 -1.9 02/07/2006 06:00:00 1.6 0.4 2.6 0.7 1.8 0.4 2.6 0.7 1.6 0.4 2.6 0.4 315 7 311 165 -1.6 0 -1.4 -1.9 02/07/2006 06:10:00 1.7 0.5 2.6 0.7 1.9 0.4 3 0.7 1.6 0.5 2.6 0.4 316 9 322 165 -1.4 0 -1.2 -1.7 02/07/2006 06:20:00 2.8 0.6 4.6 1.5 3 0.5 4.6 1.5 2.3 0.5 3.8 0.7 307 8 305 165 -1.6 0 -1.4 -1.7 02/07/2006 06:30:00 4.1 0.6 5.3 2.6 4.1 0.6 5.3 2.6 3.6 0.6 4.9 2.3 314 7 317 165 -1.9 0.1 -1.7 -2.1 02/07/2006 06:40:00 8.1 2.5 13.3 4.2 8 2.5 13.3 4.2 7.2 2.4 13 3.4 312 5 312 165 -1.7 0 -1.4 -1.9 02/07/2006 06:50:00 11.6 1.2 15.3 8.8 11.6 1.2 14.9 8.4 10.9 1.3 14.9 8 313 4 310 165 -1.9 0.2 -1.4 -2.4 02/07/2006 07:00:00 9 1.3 11.8 5.7 8.9 1.2 11.8 5.3 8.8 1.2 11.8 6.1 323 8 325 165 -2.4 0 -2.1 -2.6 02/07/2006 07:10:00 8.1 0.9 10.7 5.3 8.1 0.9 10.7 5.3 7.7 1 10.7 5.3 314 8 319 165 -2.5 0 -2.1 -2.6 02/07/2006 07:20:00 10.8 1.2 13.7 7.6 10.7 1.2 13.7 7.6 9.7 1.3 13.3 6.5 309 6 302 165 -2.5 0 -2.1 -2.6 02/07/2006 07:30:00 10.9 1.1 14.5 8.8 10.9 1.1 14.5 8.4 9.4 1.3 13.7 6.5 306 7 316 165 -2.5 0 -2.1 -2.6 02/07/2006 07:40:00 11.9 1.7 15.6 8.4 11.8 1.7 15.6 8 9.8 1.5 14.9 6.5 305 7 297 165 -2.5 0 -2.4 -2.6 02/07/2006 07:50:00 12.7 1.3 16.1 9.9 12.6 1.2 15.6 9.5 10.1 1.5 14.9 6.5 304 6 300 165 -2.5 0 -2.4 -2.6 02/07/2006 08:00:00 13.1 1.2 16.1 9.9 13 1.2 15.6 9.5 9.8 1.3 14.5 6.8 297 5 292 165 -2.5 0 -2.1 -2.6 02/07/2006 08:10:00 14.9 0.8 16.8 12.6 14.9 0.9 16.8 12.6 11.9 1.7 15.6 8 291 5 286 165 -2.4 0.1 -2.1 -2.6 02/07/2006 08:20:00 15.6 0.8 17.6 12.6 15.6 0.8 17.9 13 12.6 1.7 16.8 8.8 290 5 287 165 -2.5 0 -2.4 -2.6 02/07/2006 08:30:00 16.6 1.2 19.1 13.3 16.7 1.2 19.1 13.3 13.4 1.9 18.3 8.4 291 4 290 165 -2.4 0 -2.1 -2.6 02/07/2006 08:40:00 16.5 1.7 21 11.8 16.6 1.7 21 11.8 12.8 2.2 18.3 8 297 7 298 165 -2.4 0 -2.1 -2.6 02/07/2006 08:50:00 16.6 1.8 21.8 13.3 16.6 1.8 22.1 13 13.4 2.5 20.6 7.6 302 8 298 165 -2.3 0 -2.1 -2.6 02/07/2006 09:00:00 15.3 2.4 21.4 8.8 15.3 2.4 21.8 9.1 11.6 2.1 19.1 7.2 299 7 285 165 -2.4 0 -2.1 -2.6 02/07/2006 09:10:00 16.8 1.6 21 13 16.9 1.6 21 13 12.2 1.7 18.3 8.8 298 5 302 165 -2.4 0 -2.1 -2.6 02/07/2006 09:20:00 16.6 1.7 21 11.8 16.6 1.7 21.4 11.8 12.2 2 17.9 7.6 298 5 302 165 -2.4 0 -2.1 -2.6 02/07/2006 09:30:00 16.6 1.9 21.4 12.2 16.7 1.9 21.8 12.6 12.7 2.5 20.6 8.4 295 6 299 165 -2.5 0 -2.4 -2.6 02/07/2006 09:40:00 13.5 2.6 19.5 8.8 13.5 2.7 19.5 8.4 10.6 2.3 17.9 6.5 297 8 292 165 -2.6 0 -2.6 -2.8 02/07/2006 09:50:00 15.5 1.9 21.4 11.1 15.5 2 21.4 11.1 12.4 2.3 18.3 7.2 294 8 305 165 -2.9 0 -2.6 -3 02/07/2006 10:00:00 16.8 2 22.1 11.8 16.7 2 22.1 11.5 13.9 2.4 20.2 8 303 7 306 165 -2.9 0 -2.6 -3 02/07/2006 10:10:00 18.3 1.6 23.7 13.3 18.3 1.6 23.7 13 15.5 2.2 21 9.9 304 7 304 165 -2.8 0 -2.6 -2.8 02/07/2006 10:20:00 18.7 2.2 23.3 13.7 18.7 2.2 23.3 13.7 14.4 2.1 22.1 10.3 296 7 290 165 -2.8 0 -2.6 -3 02/07/2006 10:30:00 17.9 1.7 21.8 14.1 17.9 1.7 22.6 14.1 14.2 2.3 21.4 9.5 294 6 296 165 -2.8 0 -2.6 -3 02/07/2006 10:40:00 16.4 1.6 21.4 12.6 16.4 1.6 21.8 12.6 12.9 2 19.1 8.8 298 7 293 165 -2.9 0.1 -2.8 -3 02/07/2006 10:50:00 19.5 2.3 24.4 12.6 19.4 2.3 23.7 13 15.4 2.4 22.1 10.7 302 6 301 165 -3 0 -2.8 -3 02/07/2006 11:00:00 17.9 1.7 21.8 13 18 1.7 22.1 12.2 13.8 2.1 20.2 9.5 297 6 297 165 -2.9 0 -2.8 -3 02/07/2006 11:10:00 17.6 1.8 21.8 13 17.6 1.8 21.4 12.6 13.3 1.9 21 8.4 298 6 302 165 -3 0 -2.8 -3 02/07/2006 11:20:00 17.3 1.7 21 12.2 17.2 1.8 21.4 12.2 13.3 1.7 17.9 9.5 299 7 302 165 -3 0 -2.8 -3 02/07/2006 11:30:00 18.5 2.3 24 12.6 18.4 2.3 23.7 12.6 15.4 2.7 22.9 9.5 303 7 305 165 -3 0 -2.8 -3.3 02/07/2006 11:40:00 18 1.8 22.1 12.6 17.9 1.8 22.1 12.6 15.7 2.1 20.2 10.3 308 5 304 165 -3 0 -2.8 -3 02/07/2006 11:50:00 16.5 2.1 21.8 10.7 16.4 2.1 21 10.3 13.1 2.3 19.9 8 304 7 300 165 -2.9 0 -2.8 -3 02/07/2006 12:00:00 15.2 1.6 19.1 10.3 15.1 1.6 18.7 10.7 12.3 1.8 17.2 8 303 7 300 165 -2.8 0 -2.6 -3 02/07/2006 12:10:00 15.6 1.8 19.1 10.3 15.5 1.8 18.7 10.3 13.2 2 18.3 6.5 307 7 303 165 -2.8 0 -2.6 -2.8 02/07/2006 12:20:00 16.1 2.1 20.6 11.5 16.1 2.1 19.9 11.5 13.9 2.2 18.7 7.2 307 6 304 165 -3 0 -2.8 -3 02/07/2006 12:30:00 15.4 1.5 21 10.7 15.4 1.5 21 11.5 12.6 2.1 17.9 7.2 301 8 309 165 -3 0 -2.8 -3 02/07/2006 12:40:00 13.2 1.8 17.9 9.5 13.2 1.8 17.6 9.5 11.7 2.4 17.9 7.2 308 11 301 165 -2.8 0 -2.6 -3 02/07/2006 12:50:00 14.8 2.2 18.7 8.8 14.8 2.2 18.3 8.4 11.5 1.7 16.1 8 299 9 292 165 -2.9 0 -2.6 -3 02/07/2006 13:00:00 13.6 1.8 18.7 9.9 13.5 1.8 18.7 9.9 11.1 1.5 15.3 7.6 304 9 303 165 -2.8 0 -2.6 -3 02/07/2006 13:10:00 13.7 1.7 17.6 9.1 13.7 1.7 17.6 9.1 11.3 2 16.8 6.5 301 9 297 165 -2.8 0 -2.6 -2.8 02/07/2006 13:20:00 13.2 1.5 16.8 9.5 13.1 1.4 16.8 9.9 12.1 1.6 15.6 6.8 310 10 314 165 -2.6 0 -2.6 -2.8 02/07/2006 13:30:00 13.8 1.9 17.9 8.8 13.7 1.9 18.3 8.4 11.7 2.4 18.3 7.2 306 7 309 165 -2.6 0 -2.6 -2.8 02/07/2006 13:40:00 14.3 1.7 18.3 9.9 14.2 1.7 18.3 9.5 12.3 2.2 18.3 6.8 307 9 322 165 -2.5 0 -2.6 -2.8 02/07/2006 13:50:00 17.5 2.1 21.8 10.7 17.4 2.1 21.8 9.9 15.1 2.6 21.4 9.1 308 7 306 165 -2.5 0 -2.6 -2.6 02/07/2006 14:00:00 17.5 1.8 23.3 12.2 17.5 1.8 23.3 12.6 14.5 2.4 21.8 9.1 307 6 308 165 -2.6 0 -2.6 -2.8 02/07/2006 14:10:00 17.7 1.6 21.4 13.7 17.7 1.6 21.4 13.7 15.2 2.5 21.4 9.9 306 8 311 165 -2.5 0 -2.4 -2.6 02/07/2006 14:20:00 16 1.7 20.6 10.7 15.9 1.7 19.9 11.1 14 2.2 19.9 9.5 308 8 309 165 -2.4 0 -2.1 -2.6 02/07/2006 14:30:00 16.1 1.8 20.6 9.1 16.1 1.8 20.6 9.1 14 2.5 19.9 8.8 310 8 317 165 -2.2 0 -2.1 -2.4 02/07/2006 14:40:00 14.8 1.3 19.9 11.5 14.8 1.3 19.1 11.1 12.2 1.9 16.8 8.8 304 7 300 165 -2.2 0 -2.1 -2.4 02/07/2006 14:50:00 16.4 1.5 20.2 12.2 16.4 1.5 20.2 12.2 13.8 2.5 19.9 9.1 306 7 310 165 -2.2 0 -2.1 -2.4 02/07/2006 15:00:00 14.6 1.1 18.3 12.2 14.5 1.1 18.3 12.2 12.8 1.9 16.8 8.8 309 6 310 165 -2.2 0 -2.1 -2.4 02/07/2006 15:10:00 14.8 1.4 18.7 11.1 14.7 1.5 18.7 11.1 12.6 2 17.2 8.4 306 8 309 165 -2.1 0 -2.1 -2.1 02/07/2006 15:20:00 13.5 1.5 17.6 9.1 13.4 1.5 17.9 9.1 10.7 1.7 15.3 6.5 304 8 309 165 -2.1 0 -1.9 -2.1 02/07/2006 15:30:00 13.2 1.2 16.4 10.3 13.1 1.2 16.4 9.9 11.6 1.8 16.1 7.2 309 7 297 165 -2.1 0 -1.9 -2.1 02/07/2006 15:40:00 12.3 1.5 15.6 8 12.2 1.5 15.6 8.4 10.6 2 16.1 6.1 307 8 301 165 -2.1 0 -1.9 -2.1 02/07/2006 15:50:00 12.2 1.5 16.4 8.8 12.1 1.5 16.4 8.4 10.6 1.8 15.3 6.1 307 8 310 165 -2.1 0 -1.9 -2.1 02/07/2006 16:00:00 12.8 1.9 18.3 6.1 12.7 1.9 17.9 6.5 11.3 1.8 16.8 6.5 310 9 310 165 -2.1 0 -1.9 -2.1 02/07/2006 16:10:00 12.2 1.9 15.6 7.6 12.1 1.8 15.6 8 11.3 2.3 15.6 6.5 312 9 318 165 -2 0 -1.9 -2.1 02/07/2006 16:20:00 15.1 1.6 19.1 11.5 14.9 1.5 18.3 11.5 14.4 1.8 18.7 9.9 315 6 315 165 -2.1 0 -1.9 -2.1 02/07/2006 16:30:00 15.5 1.2 18.3 11.1 15.4 1.2 18.7 11.5 14.7 1.4 17.6 9.9 314 5 310 165 -2.1 0 -1.9 -2.1 02/07/2006 16:40:00 15.8 1.7 20.2 11.5 15.7 1.7 20.2 11.8 14.3 1.6 19.9 9.9 311 6 301 165 -2.1 0 -2.1 -2.4 02/07/2006 16:50:00 15.3 1.4 19.1 11.5 15.2 1.4 19.5 11.5 14.4 1.8 19.9 9.5 313 6 325 165 -2.2 0 -2.1 -2.4 02/07/2006 17:00:00 14.3 1.3 17.9 10.7 14.2 1.4 17.6 11.1 13.2 1.8 17.9 9.1 312 5 312 165 -2.5 0 -2.1 -2.6 02/07/2006 17:10:00 14.8 1.4 18.3 11.1 14.7 1.4 18.3 10.3 13.5 1.3 17.6 10.3 311 6 310 165 -2.6 0 -2.6 -2.8 02/07/2006 17:20:00 15.6 1.5 19.9 11.1 15.5 1.5 19.1 11.1 13 1.9 18.7 8 306 7 307 165 -2.6 0.1 -2.6 -2.8 02/07/2006 17:30:00 13.8 1.5 17.6 10.3 13.7 1.5 17.2 9.9 12.2 1.9 17.2 8.4 309 6 300 165 -2.6 0 -2.6 -2.8 02/07/2006 17:40:00 14.6 1.4 17.6 9.9 14.5 1.5 17.2 10.3 12.7 1.5 16.8 8.8 308 6 310 165 -2.8 0 -2.6 -2.8 02/07/2006 17:50:00 14.9 1.1 17.9 11.8 14.8 1.1 17.9 11.5 13.3 1.5 17.2 9.1 309 6 310 165 -2.8 0 -2.6 -2.8 02/07/2006 18:00:00 14.9 1.4 19.1 11.8 14.8 1.4 19.1 11.1 13.6 1.6 17.2 9.1 311 7 302 165 -2.8 0 -2.6 -2.8 02/07/2006 18:10:00 13.4 1.1 16.4 9.9 13.3 1.1 16.4 9.9 12.2 1.5 15.6 7.6 311 6 310 165 -2.8 0 -2.6 -2.8 02/07/2006 18:20:00 12.7 1.1 15.6 9.5 12.7 1.1 15.6 9.5 11.5 1.4 14.9 8 309 5 310 165 -2.8 0 -2.6 -2.8 02/07/2006 18:30:00 12.1 1 15.3 9.1 12 1 15.3 9.5 11.4 1.3 14.9 8 314 7 316 165 -2.8 0 -2.6 -2.8 02/07/2006 18:40:00 12.3 1.3 16.1 9.1 12.3 1.3 15.6 9.1 11.5 1.5 15.3 8.4 314 6 311 165 -2.9 0 -2.6 -3 02/07/2006 18:50:00 15.1 1.3 17.6 11.1 15 1.3 17.6 11.1 13.9 1.3 16.8 9.9 312 5 310 165 -2.7 0 -2.6 -2.8 02/07/2006 19:00:00 15.6 1.1 17.9 11.1 15.5 1.1 17.9 10.7 14.1 1.5 17.6 9.5 310 5 308 165 -2.6 0 -2.6 -2.8 02/07/2006 19:10:00 14.9 1.2 17.9 12.2 14.8 1.2 17.6 11.5 12.7 1.6 16.1 8.8 307 5 301 165 -2.6 0 -2.6 -2.8 02/07/2006 19:20:00 15 1.2 17.9 11.1 15 1.3 17.9 10.7 12.9 1.9 17.2 8.4 306 5 307 165 -2.5 0 -2.4 -2.6 02/07/2006 19:30:00 14.6 1.2 18.3 11.5 14.6 1.2 18.3 11.5 12.9 1.4 16.1 9.1 309 4 307 165 -2.6 0.1 -2.6 -2.8 02/07/2006 19:40:00 15.1 1.2 18.3 11.8 15 1.2 18.3 11.5 12.8 1.7 16.8 8.8 307 5 310 165 -2.5 0 -2.4 -2.8 02/07/2006 19:50:00 14.6 1.4 18.3 11.1 14.5 1.5 17.9 10.7 12 1.7 16.1 8 305 7 295 165 -2.5 0 -2.6 -2.8 02/07/2006 20:00:00 14.9 1.7 18.3 11.1 14.8 1.7 18.3 11.1 11.3 1.5 16.4 7.2 301 6 293 165 -2.4 0 -2.1 -2.6 02/07/2006 20:10:00 14.1 1.4 18.3 10.7 14 1.5 17.9 10.3 12.3 1.7 17.9 8.8 307 7 305 165 -2.5 0 -2.1 -2.6 02/07/2006 20:20:00 15.1 1.3 17.9 11.5 15 1.3 17.9 11.5 13.7 1.7 17.9 9.5 310 5 310 165 -2.4 0 -2.1 -2.6 02/07/2006 20:30:00 14.7 1.3 17.9 11.5 14.7 1.3 17.9 11.5 13.7 1.5 17.6 9.5 310 6 318 165 -2.5 0 -2.1 -2.6 02/07/2006 20:40:00 16 1.4 19.9 11.8 15.9 1.4 19.9 12.2 14.8 1.7 19.5 10.3 311 5 315 165 -2.4 0 -2.1 -2.6 02/07/2006 20:50:00 15.2 1.2 18.3 11.8 15.1 1.3 18.7 11.5 13.8 1.5 16.8 9.1 310 5 302 165 -2.4 0 -2.1 -2.6 02/07/2006 21:00:00 15.7 1 18.3 12.6 15.6 1.1 18.3 13 14.2 1.5 17.9 9.9 310 5 304 165 -2.3 0 -2.1 -2.6 02/07/2006 21:10:00 16.2 1.1 18.3 13.3 16.1 1.1 18.7 13.3 14.4 1.6 18.3 9.9 310 5 308 165 -2.3 0 -2.1 -2.4 02/07/2006 21:20:00 15 1 17.6 11.8 14.9 1 17.2 11.5 13.3 1.2 16.1 9.9 309 5 305 165 -2.3 0 -2.1 -2.6 02/07/2006 21:30:00 15.3 1.2 17.9 12.2 15.2 1.2 17.9 11.8 12.8 1.2 17.2 9.5 307 4 304 165 -2.3 0 -2.1 -2.6 02/07/2006 21:40:00 14.9 1 17.9 12.2 14.8 1 17.9 11.8 12.7 1.5 16.4 9.1 307 5 305 165 -2.2 0 -2.1 -2.4 02/07/2006 21:50:00 15.1 1.1 17.6 11.8 15 1.1 17.6 11.8 13.2 1.4 16.1 9.5 308 5 302 165 -2.2 0 -2.1 -2.4 02/07/2006 22:00:00 15.3 1.1 17.6 12.2 15.2 1.1 17.2 11.8 12.7 1.4 17.2 9.1 307 5 306 165 -2.1 0 -1.9 -2.4 02/07/2006 22:10:00 15.2 1 17.9 11.8 15.1 1.1 17.6 11.8 12.7 1.5 16.8 8.4 307 4 303 165 -2.2 0 -2.1 -2.4 02/07/2006 22:20:00 14.9 1.1 17.6 11.8 14.8 1.1 17.2 11.8 12 1.3 15.6 8.4 305 5 302 165 -2.2 0 -2.1 -2.4 02/07/2006 22:30:00 14.3 1.1 16.8 10.7 14.2 1.1 16.8 11.1 11.5 1.3 15.3 8.4 305 5 290 165 -2.2 0 -2.1 -2.4 02/07/2006 22:40:00 13.4 1 15.3 11.1 13.3 1 15.6 10.3 10.4 1.3 13.7 7.6 304 5 299 165 -2.2 0 -1.9 -2.4 02/07/2006 22:50:00 12.5 1 15.3 10.3 12.4 1 15.3 10.3 9.2 1.1 13.3 6.5 302 5 300 165 -2.2 0 -2.1 -2.6 02/07/2006 23:00:00 12.9 0.9 14.9 9.9 12.9 0.9 14.9 9.9 9.1 1 11.5 7.2 301 4 300 165 -2.1 0 -1.9 -2.6 02/07/2006 23:10:00 12.7 1 14.5 10.3 12.7 1 14.5 9.9 8.5 0.9 11.8 6.8 300 3 296 165 -2 0 -1.9 -2.1 02/07/2006 23:20:00 12.6 1 14.9 9.5 12.6 1 14.9 9.9 8.8 1.2 13 6.5 299 4 297 165 -2 0 -1.7 -2.1 02/07/2006 23:30:00 12.3 0.9 14.5 10.3 12.2 0.9 14.9 10.3 8.7 1.1 12.6 6.5 298 5 296 165 -2 0.1 -1.7 -2.1 02/07/2006 23:40:00 12.5 0.9 14.9 10.7 12.4 0.9 14.9 10.3 8.8 1 12.6 6.5 298 4 295 165 -2.1 0 -1.9 -2.1 02/07/2006 23:50:00 12.2 0.8 14.1 10.3 12.1 0.9 14.1 9.9 8.4 0.8 11.1 6.5 300 3 299 165 -2.1 0 -1.9 -2.1 02/08/2006 00:00:00 12.1 0.7 14.1 10.3 12 0.7 14.1 10.3 8.7 1.1 11.8 6.5 302 4 305 165 -2 0 -1.9 -2.1 02/08/2006 00:10:00 13.2 0.8 15.3 9.9 13.1 0.8 15.3 10.3 9.6 1.1 13.3 6.8 302 4 298 165 -1.8 0 -1.7 -2.1 02/08/2006 00:20:00 13.6 1 16.1 10.7 13.6 1.1 15.6 10.7 9.9 1.2 14.1 7.2 303 4 305 165 -1.9 0 -1.7 -1.9 02/08/2006 00:30:00 12.7 1 14.9 9.9 12.6 1 14.9 10.3 9 1 13 6.8 301 4 298 165 -1.9 0 -1.7 -2.1 02/08/2006 00:40:00 12.8 0.9 15.3 9.9 12.8 1 14.9 9.5 9.4 1.1 13 6.8 302 4 306 165 -1.7 0 -1.4 -1.9 02/08/2006 00:50:00 12.2 1 14.9 9.9 12.2 1 14.9 9.9 8.7 1.1 12.2 6.5 300 4 301 165 -1.8 0 -1.7 -1.9 02/08/2006 01:00:00 12.1 1 14.1 9.9 12 1 14.1 9.5 8.6 1 11.5 6.1 298 4 296 165 -1.7 0 -1.4 -1.9 02/08/2006 01:10:00 12 0.9 14.1 9.1 11.9 1 14.1 9.5 8.8 1.2 13 6.1 297 5 296 165 -1.6 0 -1.4 -1.9 02/08/2006 01:20:00 12.2 0.9 14.9 9.9 12.2 0.9 14.5 9.9 8.4 0.9 10.7 6.5 298 4 303 165 -1.6 0 -1.4 -1.7 02/08/2006 01:30:00 11.9 0.9 14.1 9.9 11.9 0.9 14.1 9.9 8.5 1 11.5 6.5 302 4 297 165 -1.3 0 -1.2 -1.4 02/08/2006 01:40:00 10.6 1.1 13.3 6.1 10.5 1.1 13.3 6.1 7.8 1 10.3 4.9 300 6 305 165 -1.2 0 -1 -1.4 02/08/2006 01:50:00 9.7 0.8 12.2 7.6 9.8 0.8 11.8 8 8.3 1.2 12.6 5.7 290 7 284 165 -1.1 0 -0.8 -1.4 02/08/2006 02:00:00 9 0.8 11.1 7.2 9.1 0.7 11.1 7.6 8.6 0.8 11.1 6.1 286 5 292 165 -1.3 0.1 -1 -1.4 02/08/2006 02:10:00 9.1 1 11.8 6.5 9.2 1 11.8 6.5 8.7 1.1 10.7 5.7 283 5 279 165 -1.2 0 -1 -1.4 02/08/2006 02:20:00 8.1 0.8 9.9 6.1 8.1 0.8 9.9 5.7 6.7 1 8.8 3.8 295 9 292 165 -1.2 0 -1 -1.4 02/08/2006 02:30:00 9.3 0.6 10.7 7.6 9.2 0.6 10.3 7.6 6.7 0.9 9.1 5.3 303 4 303 165 -1.4 0 -1.2 -1.7 02/08/2006 02:40:00 8.6 0.8 10.3 6.8 8.5 0.8 10.3 6.8 7.1 1 9.5 4.9 306 4 310 165 -1.4 0 -1.2 -1.4 02/08/2006 02:50:00 6.5 0.6 7.6 4.6 6.5 0.6 7.6 4.6 5.1 0.7 6.8 3.4 305 5 304 165 -1.7 0.1 -1.2 -1.9 02/08/2006 03:00:00 3.5 1 6.1 1.1 3.7 0.9 6.1 1.9 2.5 1.1 5.7 0.4 311 11 311 165 -2.1 0 -1.9 -2.4 02/08/2006 03:10:00 2.6 1.1 5.3 0.4 2.8 1 4.9 0.4 1.9 0.8 4.2 0.4 288 27 305 165 -2.1 0.1 -1.9 -2.4 02/08/2006 03:20:00 2.9 1.5 5.3 0.4 3 1.5 5.3 0.4 2.1 1.2 5.3 0.4 282 33 293 165 -2.1 0 -1.9 -2.4 02/08/2006 03:30:00 5.4 0.8 7.2 3 5.5 0.7 7.6 3 4.7 1 7.2 1.9 290 6 280 165 -2.4 0.1 -2.1 -2.6 02/08/2006 03:40:00 6.4 0.8 8 4.6 6.4 0.7 8 4.6 5.1 0.7 6.8 3 292 5 298 165 -1.9 0.1 -1.7 -2.1 02/08/2006 03:50:00 7.8 0.9 9.5 5.3 7.8 1 9.5 5.3 5.4 0.6 7.2 3.4 298 3 300 165 -1.7 0.1 -1.4 -1.9 02/08/2006 04:00:00 9.7 0.5 10.7 8 9.7 0.5 10.7 8 7.1 1 9.9 4.9 303 3 300 165 -1.6 0 -1.4 -1.7 02/08/2006 04:10:00 10.2 0.4 11.5 9.1 10.2 0.4 11.5 9.1 8.9 0.8 10.3 6.5 308 3 305 165 -1.6 0 -1.4 -1.7 02/08/2006 04:20:00 9.8 0.6 11.1 7.6 9.7 0.7 11.1 7.6 7.4 0.8 9.5 4.2 305 3 305 165 -1.6 0 -1.4 -1.7 02/08/2006 04:30:00 10.4 0.7 11.8 7.6 10.3 0.7 11.5 7.6 7.8 0.8 10.7 5.7 304 3 308 165 -1.6 0 -1.4 -1.9 02/08/2006 04:40:00 10.5 1.2 13 6.8 10.4 1.2 13 7.2 8.5 1.1 12.2 5.3 305 6 308 165 -1.5 0 -1.2 -1.7 02/08/2006 04:50:00 11.8 0.8 13.3 8.8 11.7 0.8 13.7 8.4 9.4 1.1 11.8 6.1 306 4 301 165 -1.4 0 -1.2 -1.4 02/08/2006 05:00:00 10.9 1.3 13.7 6.8 10.8 1.3 13.3 6.8 8.2 0.9 10.3 5.3 302 6 299 165 -1.3 0 -1.2 -1.4 02/08/2006 05:10:00 10.3 0.9 12.2 7.6 10.3 0.9 12.6 7.6 8.5 1.1 11.8 5.7 291 5 286 165 -1.3 0 -1.2 -1.4 02/08/2006 05:20:00 9.5 1 11.5 6.5 9.5 1 11.5 6.5 7.6 1.1 10.7 4.9 294 7 292 165 -1.4 0 -1.4 -1.7 02/08/2006 05:30:00 5.9 2.4 9.9 1.1 6 2.3 9.9 1.9 4.9 1.6 8.8 1.5 305 11 302 165 -1.3 0 -1.2 -1.4 02/08/2006 05:40:00 3.2 0.6 4.6 1.5 3.4 0.5 4.6 1.9 3.4 0.5 4.6 1.9 293 10 289 165 -1.4 0 -1.2 -1.7 02/08/2006 05:50:00 4.4 0.9 6.1 1.9 4.6 0.9 6.1 1.9 4.2 1.2 6.5 1.9 289 9 279 165 -1.3 0.1 -1.2 -1.7 02/08/2006 06:00:00 2.2 0.6 4.6 0.7 2.5 0.5 4.6 1.1 2.5 0.4 3.8 1.5 305 11 302 165 -1.6 0.1 -1.2 -1.9 02/08/2006 06:10:00 0.9 0.5 2.3 0.4 1.5 0.4 2.6 0.7 1.8 0.4 2.6 1.1 325 12 328 165 -1.4 0 -1.2 -1.4 02/08/2006 06:20:00 0.8 0.6 1.9 0.4 1.3 0.7 2.6 0.4 1.6 0.4 2.6 1.1 343 5 332 165 -1.7 0.1 -1.2 -1.9 02/08/2006 06:30:00 1.6 0.7 3 0.4 1.9 0.8 3.4 0.4 2.4 0.6 3.4 1.5 18 19 46 165 -1.6 0.1 -1.2 -1.9 02/08/2006 06:40:00 1.1 0.9 3 0.4 1.5 1 3.4 0.4 1.8 0.8 3.4 0.4 41 29 48 165 -1.4 0 -1.2 -1.4 02/08/2006 06:50:00 1.3 1.3 4.2 0.4 1.7 1.2 4.6 0.4 1.6 1.2 4.6 0.4 152 94 104 165 -1.7 0.2 -1.4 -2.1 02/08/2006 07:00:00 1.8 1 3.8 0.4 2.1 0.9 4.2 0.4 2 1 3.8 0.4 148 21 189 165 -1.4 0.1 -1 -1.7 02/08/2006 07:10:00 3.2 1 5.3 1.1 3.4 0.9 5.3 1.5 3.3 0.9 5.3 1.9 147 14 161 165 -2 0.2 -1.2 -2.6 02/08/2006 07:20:00 4.1 0.6 5.7 2.3 4.2 0.6 5.3 2.6 4 0.6 4.9 2.6 162 10 165 165 -2 0.1 -1.7 -2.4 02/08/2006 07:30:00 4.8 0.6 5.7 2.6 4.7 0.6 5.7 3 4.7 0.6 5.7 3 165 5 167 165 -1.7 0 -1.4 -1.9 02/08/2006 07:40:00 3.1 0.5 4.6 1.9 3.4 0.5 4.6 2.3 3.1 0.5 4.2 2.3 148 8 164 165 -1.9 0 -1.9 -1.9 02/08/2006 07:50:00 3.5 0.3 4.2 2.6 3.6 0.3 4.2 2.6 3.5 0.4 4.2 2.6 157 12 153 165 -2 0 -1.7 -2.1 02/08/2006 08:00:00 3 0.3 3.8 2.3 3.2 0.3 4.2 2.6 2.9 0.4 3.8 1.9 150 15 162 165 -1.8 0.1 -1.7 -2.1 02/08/2006 08:10:00 3.1 0.5 4.2 1.9 3.4 0.5 4.6 2.3 3.1 0.4 4.2 1.9 135 8 136 165 -1.6 0.2 -1.2 -1.9 02/08/2006 08:20:00 3.3 0.6 4.6 1.9 3.5 0.5 4.9 1.9 3.2 0.5 4.6 1.9 145 13 157 165 -1.4 0 -1.2 -1.7 02/08/2006 08:30:00 4.4 0.6 5.7 2.6 4.6 0.6 5.7 3 4.3 0.7 5.3 2.6 143 4 137 165 -1.6 0.1 -1.2 -1.7 02/08/2006 08:40:00 5.1 0.4 5.7 3.8 5.2 0.4 6.1 4.2 4.9 0.5 6.1 3.4 150 4 154 165 -1.3 0 -1.2 -1.4 02/08/2006 08:50:00 4.8 0.6 6.1 3.4 4.9 0.5 6.1 3.8 4.8 0.5 6.1 3.4 151 6 150 165 -1 0.1 -0.8 -1.2 02/08/2006 09:00:00 4.5 0.7 6.5 2.3 4.6 0.6 6.5 2.3 4.6 0.6 6.1 3 154 7 152 165 -0.9 0 -0.8 -1 02/08/2006 09:10:00 4.8 0.7 6.5 3 4.9 0.6 6.5 3.4 4.7 0.6 6.1 3.4 148 6 145 165 -1 0 -0.8 -1.2 02/08/2006 09:20:00 5.1 1 6.8 2.6 5.2 1 6.8 3 5.2 1 6.8 2.6 147 6 147 165 -1.2 0 -1 -1.2 02/08/2006 09:30:00 5.1 1 6.5 1.9 5.2 0.9 6.5 2.6 5.3 0.9 6.8 2.6 149 7 151 165 -1.1 0 -1 -1.2 02/08/2006 09:40:00 4.3 0.9 6.5 1.9 4.5 0.9 6.5 2.6 4.7 0.8 6.8 3 156 10 148 165 -1 0 -0.8 -1.2 02/08/2006 09:50:00 3.4 0.6 4.6 2.3 3.6 0.5 4.6 2.6 3.6 0.5 4.6 2.6 160 7 155 165 -1.1 0 -0.8 -1.4 02/08/2006 10:00:00 3.6 0.6 4.6 2.3 3.8 0.5 4.6 2.6 3.8 0.5 4.9 2.6 166 7 165 165 -1 0 -0.8 -1.2 02/08/2006 10:10:00 3.8 0.6 5.3 2.3 3.9 0.5 5.3 2.6 3.9 0.5 4.9 2.6 163 12 179 165 -1 0 -0.8 -1.2 02/08/2006 10:20:00 5.2 0.6 6.8 3.8 5.1 0.6 6.5 3.4 5.2 0.5 6.5 3.8 163 6 171 165 -1.2 0 -0.8 -1.4 02/08/2006 10:30:00 5.2 0.6 6.8 3.8 5.1 0.5 6.5 3.8 4.9 0.5 6.1 3.4 174 6 163 165 -1.2 0 -1 -1.4 02/08/2006 10:40:00 6.6 0.3 7.2 5.7 6.4 0.3 6.8 5.3 6 0.4 6.5 4.9 178 3 176 165 -0.9 0.1 -0.5 -1.2 02/08/2006 10:50:00 6.4 0.4 7.2 4.9 6.3 0.4 7.2 5.3 6.4 0.5 7.6 4.9 179 2 178 165 -0.3 0.2 0.2 -0.8 02/08/2006 11:00:00 5.7 0.3 6.5 4.9 5.6 0.3 6.1 4.9 5.7 0.3 6.5 4.9 174 6 179 165 0.1 0 0.2 -0.1 02/08/2006 11:10:00 5.6 0.4 6.5 4.6 5.5 0.3 6.5 4.6 5.5 0.3 6.5 4.6 163 7 156 165 0.2 0 0.2 -0.1 02/08/2006 11:20:00 5.1 0.6 6.8 3.8 5.1 0.6 6.5 3.8 5.2 0.6 6.8 3.8 161 7 165 165 0.2 0 0.4 0.2 02/08/2006 11:30:00 5.4 0.6 6.8 4.2 5.3 0.5 6.8 4.2 5.4 0.5 6.5 4.6 155 6 164 165 0.1 0 0.2 -0.1 02/08/2006 11:40:00 5.8 0.7 7.2 3.8 5.8 0.7 7.6 3.4 5.6 0.6 6.8 4.2 146 6 150 165 0.1 0 0.2 -0.1 02/08/2006 11:50:00 5.8 0.7 7.6 4.2 5.9 0.6 7.6 4.2 5.8 0.6 7.2 4.6 144 6 142 165 0.4 0 0.7 0.2 02/08/2006 12:00:00 5.5 0.8 8 3.8 5.6 0.7 8 3.8 5.5 0.8 8.4 3.8 144 9 161 165 0.7 0 0.9 0.7 02/08/2006 12:10:00 5.7 0.9 8.8 3.4 5.7 0.8 8.8 3.4 5.7 0.7 8 3.8 142 11 134 165 0.6 0 0.9 0.7 02/08/2006 12:20:00 6.2 0.9 9.1 4.6 6.2 0.8 9.1 4.6 6.1 0.8 8.4 4.2 148 9 151 165 0.5 0 0.7 0.4 02/08/2006 12:30:00 8 1.3 11.1 4.9 7.9 1.3 11.1 4.9 8 1.3 11.1 5.3 151 15 150 165 0.7 0.1 0.9 0.7 02/08/2006 12:40:00 7.6 1.3 10.3 4.2 7.5 1.2 10.3 3.8 7.6 1.3 10.7 3.8 157 13 155 165 1.1 0.1 1.4 0.9 02/08/2006 12:50:00 10.8 1.1 12.6 7.6 10.8 1.1 12.6 7.6 10.8 1.2 12.6 6.8 150 5 145 165 1.6 0.2 1.8 1.4 02/08/2006 13:00:00 10.8 1 13.3 8.8 10.8 1 13.3 8.8 10.8 1 13.7 8 149 6 150 165 1.9 0 1.8 1.8 02/08/2006 13:10:00 13.6 0.9 15.6 11.5 13.6 0.9 15.6 11.1 13.6 1.1 16.8 10.7 151 4 156 165 1.7 0 1.8 1.6 02/08/2006 13:20:00 14.7 1 16.8 11.8 14.6 1 16.4 11.5 14.7 1.1 16.8 11.5 151 5 147 165 1.5 0 1.8 1.4 02/08/2006 13:30:00 14.8 0.6 16.4 13 14.8 0.6 16.1 13 14.8 0.8 17.2 11.8 149 4 154 165 1.5 0 1.6 1.4 02/08/2006 13:40:00 16 0.6 17.9 14.1 15.9 0.6 17.6 14.1 15.9 0.8 17.9 12.6 150 4 153 165 1.5 0 1.6 1.4 02/08/2006 13:50:00 14.9 1.1 17.9 12.6 14.9 1.1 17.9 12.6 14.8 1.3 18.7 11.5 149 4 152 165 1.5 0 1.8 1.4 02/08/2006 14:00:00 14.8 0.9 17.2 12.6 14.8 0.9 17.2 13 14.8 1 17.2 11.1 147 5 145 165 1.7 0 1.8 1.6 02/08/2006 14:10:00 15.5 1.2 17.9 11.8 15.4 1.2 17.9 12.2 15.4 1.5 18.7 10.7 148 4 156 165 1.8 0 1.8 1.6 02/08/2006 14:20:00 14.7 1 17.2 11.8 14.7 1 16.8 11.5 14.7 1.2 17.2 11.1 148 5 148 165 1.7 0 1.8 1.6 02/08/2006 14:30:00 14.9 1.1 17.6 11.8 14.9 1.1 17.6 11.5 15 1.2 17.9 10.3 147 4 139 165 1.8 0 1.8 1.6 02/08/2006 14:40:00 15.3 1.2 17.9 11.8 15.3 1.2 17.9 11.8 15.4 1.2 18.3 11.8 145 4 144 165 1.8 0 1.8 1.6 02/08/2006 14:50:00 16.6 1 18.7 13.3 16.6 1 18.7 13.3 16.7 1.2 19.1 12.6 146 4 148 165 1.9 0 1.8 1.8 02/08/2006 15:00:00 16.8 0.9 18.7 14.1 16.8 0.9 18.7 14.1 16.6 1.2 19.1 13 145 4 144 165 1.7 0 1.8 1.6 02/08/2006 15:10:00 17 1 19.1 13.7 16.9 1 19.1 13.7 16.9 1.2 19.1 13 146 5 147 165 1.6 0 1.8 1.4 02/08/2006 15:20:00 16.7 1 18.7 13.3 16.7 1 18.7 13 16.8 1.1 19.5 13.7 148 4 147 165 1.6 0 1.6 1.4 02/08/2006 15:30:00 16.9 1.2 19.5 13.7 16.9 1.1 19.5 13.7 16.7 1.4 19.9 13.3 147 6 145 165 1.6 0 1.6 1.4 02/08/2006 15:40:00 18.6 1.3 21.8 14.5 18.6 1.3 21.4 14.5 18.6 1.5 21.8 13.7 148 5 150 165 1.5 0 1.6 1.4 02/08/2006 15:50:00 19.1 1.6 22.1 14.1 19 1.5 21.8 14.1 19.1 1.7 21.8 13.7 148 5 148 165 1.5 0 1.6 1.4 02/08/2006 16:00:00 19.2 1 22.1 16.1 19.2 1 21.8 16.1 19.2 1.2 22.1 15.3 146 3 145 165 1.6 0 1.6 1.6 02/08/2006 16:10:00 18.4 1.1 20.6 14.5 18.3 1.1 20.2 14.5 18.4 1.2 21 14.9 148 5 153 165 1.6 0 1.6 1.6 02/08/2006 16:20:00 19.5 1.1 22.6 15.3 19.4 1.1 22.6 15.3 19.3 1.3 22.1 14.9 146 4 138 165 1.6 0 1.6 1.6 02/08/2006 16:30:00 19.6 1 22.1 16.8 19.5 1.1 22.6 16.4 19.6 1.2 22.6 16.4 144 4 141 165 1.7 0 1.8 1.6 02/08/2006 16:40:00 19 1.4 21.8 14.5 18.9 1.4 21.4 14.9 18.9 1.5 21.8 14.1 147 5 151 165 1.7 0 1.8 1.6 02/08/2006 16:50:00 19.3 1.4 22.6 16.1 19.2 1.4 22.6 15.3 19.2 1.6 22.6 14.1 147 5 135 165 1.7 0 1.8 1.6 02/08/2006 17:00:00 20.8 1.1 23.7 17.6 20.7 1.2 23.7 17.6 20.7 1.3 23.7 17.2 145 4 141 165 1.7 0 1.8 1.6 02/08/2006 17:10:00 19.9 0.9 22.1 16.4 19.9 0.8 21.8 16.8 19.8 1.1 22.1 16.4 145 5 146 165 1.8 0 1.8 1.6 02/08/2006 17:20:00 20.2 1.5 23.3 16.1 20.1 1.5 22.9 16.1 20.2 1.5 23.3 16.1 145 4 147 165 1.8 0 1.8 1.8 02/08/2006 17:30:00 20.3 1.7 23.7 16.1 20.1 1.6 23.3 15.6 20.4 1.7 24 14.5 149 3 151 165 1.9 0 1.8 1.8 02/08/2006 17:40:00 19.8 1.6 23.7 16.1 19.8 1.5 23.3 16.1 19.9 1.6 22.9 16.8 146 6 154 165 1.9 0 1.8 1.8 02/08/2006 17:50:00 19.5 1.7 22.1 14.1 19.4 1.7 22.6 14.5 19.5 1.9 23.3 13.7 145 4 141 165 1.9 0 1.8 1.8 02/08/2006 18:00:00 19.1 1.2 21.8 14.5 19 1.2 21.8 15.3 18.9 1.5 21.8 13.7 146 5 147 165 1.9 0 1.8 1.8 02/08/2006 18:10:00 19.6 1.3 21.8 14.1 19.5 1.3 21.8 14.1 19.5 1.5 22.1 14.9 145 5 147 165 1.9 0 2.1 1.8 02/08/2006 18:20:00 19.2 1.5 22.6 14.9 19.1 1.5 22.6 15.3 19.1 1.7 22.6 14.5 145 5 145 165 1.9 0 2.1 1.8 02/08/2006 18:30:00 19.6 1.4 22.9 14.9 19.6 1.4 22.9 14.9 19.7 1.5 23.7 14.9 147 5 151 165 2 0 2.3 1.8 02/08/2006 18:40:00 20.8 1.7 24 14.9 20.8 1.8 24 14.5 20.7 1.9 23.7 14.1 144 4 145 165 2 0 2.3 1.8 02/08/2006 18:50:00 20.5 1.2 23.3 16.8 20.4 1.1 23.3 17.2 20.5 1.2 23.7 16.4 147 4 149 165 2 0 2.3 1.8 02/08/2006 19:00:00 19.2 1.5 22.9 15.6 19.2 1.5 22.9 15.6 19.3 1.7 22.9 15.6 145 5 150 165 2 0 2.3 1.8 02/08/2006 19:10:00 19.9 1.9 24 14.5 19.9 1.8 23.7 14.9 19.7 2.1 23.7 14.1 145 6 144 165 2.1 0 2.3 1.8 02/08/2006 19:20:00 20.4 1.2 22.9 17.2 20.4 1.2 22.6 16.8 20.3 1.5 23.3 16.1 144 5 148 165 2.1 0 2.3 1.8 02/08/2006 19:30:00 18.8 1.5 22.1 14.5 18.8 1.5 22.1 14.5 18.6 1.5 22.6 14.5 141 6 149 165 2.1 0 2.3 1.8 02/08/2006 19:40:00 19.3 1.5 22.9 15.6 19.3 1.4 22.9 16.1 19.3 1.6 23.7 14.9 144 5 148 165 2.1 0 2.3 1.8 02/08/2006 19:50:00 19.1 1.6 22.9 14.9 19.1 1.5 22.9 14.9 19.2 1.7 23.3 14.5 145 6 153 165 2.1 0 2.3 1.8 02/08/2006 20:00:00 20.6 1.5 24.4 14.9 20.6 1.5 24.8 15.3 20.6 1.6 24.8 16.4 142 5 136 165 2.1 0 2.3 2.1 02/08/2006 20:10:00 19.4 1 21.8 16.8 19.5 1 22.1 16.8 19.2 1.2 22.1 15.6 141 6 135 165 2.1 0 2.3 1.8 02/08/2006 20:20:00 20.3 1.7 24.4 16.1 20.2 1.7 24.4 15.3 20.2 1.7 23.7 15.3 144 5 135 165 2.1 0 2.3 2.1 02/08/2006 20:30:00 21.4 1.3 24 17.2 21.3 1.3 24.4 17.6 21.2 1.5 24.8 16.8 142 6 139 165 2.1 0 2.3 2.1 02/08/2006 20:40:00 21.1 1.7 24.8 17.2 21 1.7 24.4 16.8 21.3 1.7 25.6 17.2 146 5 145 165 2.1 0 2.3 2.1 02/08/2006 20:50:00 20 1.9 23.3 14.1 20 1.9 23.7 14.1 20.1 2.1 24.4 12.6 145 5 147 165 2.1 0 2.3 2.1 02/08/2006 21:00:00 18.3 1.2 21 15.3 18.3 1.2 21 15.6 18.1 1.5 22.1 13 141 6 143 165 2.1 0 2.3 2.1 02/08/2006 21:10:00 20.1 1.5 24 16.1 20.2 1.5 24 15.6 19.8 1.7 24 14.9 138 6 132 165 2 0 2.3 1.8 02/08/2006 21:20:00 18.3 1.1 21 15.3 18.4 1.2 21.8 14.9 18.1 1.3 21.8 14.1 140 6 138 165 2 0 2.3 1.8 02/08/2006 21:30:00 18.5 1.6 22.9 14.9 18.5 1.6 22.9 14.5 18.3 1.7 22.9 14.1 142 6 139 165 2.1 0 2.3 2.1 02/08/2006 21:40:00 19.4 1.8 23.7 15.6 19.4 1.9 23.7 15.6 19.3 2.1 24 13 142 5 139 165 2 0.1 2.3 1.8 02/08/2006 21:50:00 17.5 1.2 21.8 14.1 17.5 1.2 21.8 14.1 17.5 1.3 21.8 13.7 144 6 145 165 1.8 0 1.8 1.6 02/08/2006 22:00:00 16.8 1.3 20.6 13.7 16.8 1.3 20.6 13.7 16.6 1.5 20.2 11.8 144 6 133 165 1.7 0 1.8 1.6 02/08/2006 22:10:00 18.4 1.7 22.9 13.7 18.4 1.7 22.9 14.5 18.3 2 23.7 13 140 7 139 165 1.9 0.1 2.1 1.6 02/08/2006 22:20:00 20 2.8 26.8 14.1 20.1 2.8 27.1 14.5 19.7 2.9 26.8 13.3 135 7 137 165 1.8 0.3 2.3 1.1 02/08/2006 22:30:00 19.4 2.2 24.8 14.1 19.5 2.2 24.8 14.1 19.3 2.2 24 14.9 139 6 135 165 1.2 0.1 1.4 0.9 02/08/2006 22:40:00 18.2 1.6 22.9 13.7 18.3 1.6 23.3 14.1 17.8 1.8 23.3 13 135 8 120 165 1.5 0 1.6 1.4 02/08/2006 22:50:00 18.2 2 23.3 11.5 18.3 2.1 23.7 11.1 18.3 2 23.7 12.6 137 7 133 165 1.8 0.1 1.8 1.6 02/08/2006 23:00:00 16.2 1.6 21 12.6 16.4 1.7 21.4 12.6 16 1.9 21.8 11.5 130 7 130 165 1.9 0 2.1 1.8 02/08/2006 23:10:00 16.6 3.1 22.9 9.9 16.9 3.1 23.7 9.9 16.3 3.1 23.7 9.9 122 8 126 165 1.8 0.2 2.1 1.1 02/08/2006 23:20:00 17.3 1.8 21.8 12.6 17.7 1.7 22.1 13 17.1 1.7 21.4 12.6 120 6 112 165 0.8 0.1 1.4 0.9 02/08/2006 23:30:00 17.4 3.1 30.6 12.2 17.8 3.2 30.9 11.5 17 3.2 30.6 11.8 122 8 131 165 1 0 1.4 0.9 02/08/2006 23:40:00 21.3 4.9 30.9 10.7 21.4 4.9 30.9 10.3 21 4.9 30.6 9.9 136 8 136 165 0.1 0.3 1.1 -0.3 02/08/2006 23:50:00 15.1 2.5 24.4 10.7 15.3 2.5 24.8 11.1 15 2.5 22.9 9.5 128 8 108 165 -0.1 0 0.2 -0.3 02/09/2006 00:00:00 15 1.9 20.6 9.1 15.2 2 21.4 9.9 14.6 2 20.2 9.5 125 9 120 165 0.4 0 0.7 0.2 02/09/2006 00:10:00 17.1 3.8 26.3 9.1 17.3 3.6 26.3 9.9 16.5 3.8 24.8 8 125 9 136 165 0.7 0.1 0.9 0.7 02/09/2006 00:20:00 17.9 3.1 25.6 11.8 17.9 3.1 25.6 12.6 17.7 3.1 25.6 11.5 137 13 139 165 0.4 0 0.7 0.2 02/09/2006 00:30:00 17.8 1.8 22.6 13.3 17.9 1.8 22.6 13.3 17.3 2.1 22.9 12.2 133 7 148 165 0.2 0 0.4 0.2 02/09/2006 00:40:00 17.6 1.7 21.8 13.3 17.9 1.7 22.1 13 17.3 1.9 22.6 12.2 126 7 124 165 0.2 0 0.4 0.2 02/09/2006 00:50:00 16.6 1.5 20.6 13 16.9 1.6 21.4 13.3 16.5 1.6 20.6 11.8 125 6 123 165 0.3 0 0.4 0.2 02/09/2006 01:00:00 14.5 2.1 19.5 8.8 14.9 2.1 20.2 8.8 14.2 2.2 19.9 6.8 119 8 119 165 0.3 0 0.4 0.2 02/09/2006 01:10:00 15.4 1.6 18.3 10.3 15.9 1.7 18.7 10.7 14.9 1.8 18.7 9.5 113 7 116 165 0.5 0 0.7 0.2 02/09/2006 01:20:00 16.8 1.7 20.6 11.5 17.2 1.7 21 11.5 15.9 2.1 20.6 9.5 109 6 103 165 0.5 0 0.7 0.4 02/09/2006 01:30:00 17.9 1.5 21.8 12.6 18.3 1.6 22.1 13.3 17.5 1.8 21.8 11.1 110 6 108 165 0.6 0 0.7 0.7 02/09/2006 01:40:00 16.1 1.8 20.6 10.7 16.5 1.9 21.4 10.7 15.5 2.1 20.6 10.7 110 7 111 165 0.7 0 0.9 0.7 02/09/2006 01:50:00 18.2 2 23.3 13 18.6 2.1 24 13.3 17.4 2.2 22.6 12.6 108 6 105 165 0.8 0 0.9 0.7 02/09/2006 02:00:00 17.1 2 22.1 11.5 17.5 2 22.6 10.3 16.5 2.2 21.8 11.1 105 7 113 165 0.8 0 0.9 0.7 02/09/2006 02:10:00 19.6 2.4 24.4 13.3 20.1 2.5 24.8 13.3 19 2.4 24.8 12.2 105 8 114 165 0.8 0 0.9 0.7 02/09/2006 02:20:00 16.4 2.5 24 9.9 16.7 2.5 24.8 9.5 15.6 2.6 24.4 9.1 107 8 116 165 0.6 0 0.9 0.7 02/09/2006 02:30:00 16.1 1.9 21.8 11.8 16.4 2 22.1 10.7 15.3 1.9 21 10.3 100 9 96 165 0.6 0 0.9 0.7 02/09/2006 02:40:00 18.3 1.7 22.6 13.7 18.7 1.7 23.3 13.7 17.6 2 22.9 12.2 96 8 93 165 0.6 0 0.9 0.7 02/09/2006 02:50:00 17.4 1.7 21.8 13.3 17.7 1.8 22.1 13.3 16.6 2.1 21.4 11.1 94 7 89 165 0.8 0 0.9 0.7 02/09/2006 03:00:00 18.8 2.2 25.2 11.8 19.1 2.3 25.2 12.6 18 2.3 23.3 12.2 94 7 88 165 0.8 0 0.9 0.7 02/09/2006 03:10:00 17.9 2.3 24.8 11.1 18.2 2.4 24.8 11.5 17.5 2.4 22.6 11.5 93 8 107 165 0.8 0 0.9 0.9 02/09/2006 03:20:00 16.2 2.1 21.8 11.8 16.4 2.2 21.8 11.8 16.1 2.1 22.6 10.3 84 8 92 165 0.8 0 0.9 0.9 02/09/2006 03:30:00 17.2 2 22.9 12.2 17.4 2.2 22.9 12.2 17 2.1 22.6 12.2 83 8 83 165 0.8 0 0.9 0.7 02/09/2006 03:40:00 16.6 2.1 22.6 10.7 16.8 2.2 22.9 10.7 16.5 2.1 22.1 11.5 83 9 90 165 0.8 0 0.9 0.7 02/09/2006 03:50:00 18.1 2.6 25.6 12.6 18.3 2.6 25.6 12.6 17.9 2.6 25.6 12.6 81 9 88 165 0.8 0 0.9 0.7 02/09/2006 04:00:00 17 2.4 22.1 11.5 17.2 2.5 22.6 11.8 17.1 2.3 22.1 11.8 100 3 101 165 0.8 0 0.9 0.7 02/09/2006 04:10:00 18.2 3.1 24 11.8 18.6 3.1 24.4 12.2 18.1 2.9 24.8 11.8 101 0 101 165 0.8 0 0.9 0.7 02/09/2006 04:20:00 15.4 2.2 21 10.3 15.8 2.2 21.4 10.7 15.6 2.3 21.8 10.7 101 0 101 165 0.8 0 0.9 0.7 02/09/2006 04:30:00 15 2.3 20.6 10.3 15.4 2.3 20.6 10.3 15 2.4 21 9.1 101 0 101 165 0.7 0 0.9 0.7 02/09/2006 04:40:00 14.5 2.2 19.5 9.5 14.8 2.2 20.2 9.5 14.7 2.1 21.4 9.5 101 0 101 165 0.7 0 0.9 0.7 02/09/2006 04:50:00 14.5 2.6 20.6 8.8 14.4 2.5 20.6 8.8 14.9 2.6 22.1 9.1 101 0 101 165 0.8 0 0.9 0.7 02/09/2006 05:00:00 15.5 2.6 21.4 9.5 15.4 2.6 21.4 9.5 15.6 2.4 20.6 9.1 100 0 101 165 0.8 0 0.9 0.7 02/09/2006 05:10:00 15.6 2.7 24 10.3 15.7 2.7 24.4 10.7 15.9 2.6 23.3 11.1 100 0 101 165 0.8 0 0.9 0.7 02/09/2006 05:20:00 15.9 2.2 21.8 10.3 16 2.2 21.8 9.9 16.3 2.2 22.6 10.3 100 0 101 165 0.7 0 0.9 0.7 02/09/2006 05:30:00 15.1 2.3 20.2 9.5 15.2 2.4 20.6 9.1 15.4 2.4 21.4 9.1 100 0 101 165 0.7 0 0.9 0.7 02/09/2006 05:40:00 14 2.4 21.4 8.8 14.2 2.5 21.4 8.8 14.3 2.4 21.4 9.1 100 0 100 165 0.7 0 0.9 0.7 02/09/2006 05:50:00 14.2 2.4 21.4 7.2 14.4 2.3 20.6 7.6 14.6 2.3 20.2 8.4 100 0 100 165 0.7 0 0.9 0.7 02/09/2006 06:00:00 14.4 2.4 20.6 9.5 14.6 2.5 20.6 9.5 14.7 2.4 20.2 9.1 100 0 101 165 0.6 0 0.7 0.7 02/09/2006 06:10:00 12.7 2.4 20.6 8 12.8 2.5 20.6 8 12.8 2.5 20.2 7.6 100 0 100 165 0.6 0 0.7 0.7 02/09/2006 06:20:00 12.8 2.4 18.7 7.2 13 2.5 18.7 7.6 13.1 2.5 19.9 6.1 100 0 100 165 0.7 0 0.9 0.7 02/09/2006 06:30:00 12.4 2.5 19.9 6.8 12.6 2.5 19.9 7.2 12.8 2.5 19.1 7.6 100 0 101 165 0.7 0 0.9 0.7 02/09/2006 06:40:00 13 2 19.5 8 12.9 2.1 19.5 7.2 13.3 2 20.2 8.8 100 0 100 165 0.8 0 0.9 0.7 02/09/2006 06:50:00 11.5 2.7 20.2 6.1 11.1 2.9 19.9 4.9 11.9 2.8 19.9 6.1 100 0 100 165 0.8 0 0.9 0.7 02/09/2006 07:00:00 11.9 2.4 18.3 6.8 11.3 2.7 18.3 5.3 12.3 2.5 19.1 7.2 100 0 100 165 0.8 0 0.9 0.7 02/09/2006 07:10:00 10.5 2.7 18.7 3.8 9.9 3.1 19.1 2.3 10.6 2.7 17.6 4.6 100 0 100 165 0.7 0 0.9 0.7 02/09/2006 07:20:00 9.1 1.8 13.7 5.3 8.6 2 13.7 3.8 9.1 2.1 14.5 3.4 100 0 100 165 0.7 0 0.9 0.7 02/09/2006 07:30:00 10.2 2.3 15.6 4.9 10.1 2.6 16.1 4.2 10.5 2.6 15.6 3.8 100 0 100 165 0.8 0 0.9 0.7 02/09/2006 07:40:00 8.4 2.5 15.6 3 8.6 2.6 15.6 2.6 8.5 2.7 14.9 1.5 100 0 100 165 0.8 0 0.9 0.7 02/09/2006 07:50:00 7.7 1.8 12.2 3 7.2 2 12.2 1.9 7.4 1.9 12.2 3 100 0 100 165 0.7 0 0.9 0.7 02/09/2006 08:00:00 5.7 2.1 11.1 1.5 5.6 2.2 11.8 1.1 5.9 2.3 12.2 1.1 100 0 100 165 0.6 0 0.9 0.7 02/09/2006 08:10:00 5.1 1.7 9.5 0.7 5.6 2 10.3 1.5 5.3 2 9.9 1.1 100 0 101 165 0.6 0 0.9 0.7 02/09/2006 08:20:00 5.2 1.5 9.5 1.9 5 1.7 9.1 1.5 5 1.6 9.1 1.1 100 0 101 165 0.5 0 0.7 0.2 02/09/2006 08:30:00 6.1 1.3 10.3 3 6.2 1.3 9.9 3.4 6.9 1.5 10.7 3.8 100 0 101 165 0.3 0 0.7 0.2 02/09/2006 08:40:00 6.8 0.8 9.9 4.6 7 1.1 9.5 4.6 8.4 1 11.1 5.3 100 0 101 165 0.4 0 0.7 0.2 02/09/2006 08:50:00 7.1 0.7 8.8 5.3 8.1 0.8 9.9 6.1 9.2 0.8 11.1 6.8 100 0 101 165 0.5 0 0.7 0.4 02/09/2006 09:00:00 7.1 1.1 9.9 3.4 8 1 10.3 4.6 8.8 1.2 11.8 5.3 100 0 100 165 0.7 0 0.9 0.7 02/09/2006 09:10:00 7.8 0.8 9.5 5.3 8.2 0.9 11.1 5.7 8.8 1.1 11.8 5.7 100 0 100 165 0.8 0 1.1 0.9 02/09/2006 09:20:00 6.4 1.3 9.1 2.3 6.7 1.3 9.5 3.4 7 1.4 9.9 3.8 100 0 100 165 0.9 0 1.1 0.9 02/09/2006 09:30:00 5.2 1 8.8 1.9 5.2 1 9.1 1.9 5.2 1.1 8.8 2.3 99 0 100 165 1.2 0.1 1.4 0.9 02/09/2006 09:40:00 5.4 1.8 10.7 1.9 5.5 1.7 11.1 1.9 4.9 1.3 9.1 2.3 99 0 99 165 1.5 0 1.6 1.4 02/09/2006 09:50:00 11.2 1.2 14.1 8 11.5 1.2 14.5 8 11.1 1.3 13.7 6.8 99 0 98 165 2.7 0.5 3.3 1.6 02/09/2006 10:00:00 10.8 1.3 14.1 8.4 11 1.2 14.5 8 10.6 1.2 14.1 7.2 105 7 101 165 3.6 0.1 3.8 3.3 02/09/2006 10:10:00 10.5 0.9 12.6 7.2 10.6 1 12.6 7.6 10.1 1 12.2 6.8 116 7 120 165 4 0.1 4.3 3.8 02/09/2006 10:20:00 9 1.3 12.6 6.1 8.9 1.3 12.2 6.1 8.7 1.3 12.6 5.3 126 9 122 165 4.1 0 4.3 4.3 02/09/2006 10:30:00 7.8 1.1 10.3 4.6 7.8 1.1 10.7 4.6 7.7 1.1 10.7 4.9 133 9 117 165 4.2 0 4.3 4.3 02/09/2006 10:40:00 6.4 0.9 8.8 3.8 6.4 0.9 8.4 3.8 6.3 0.8 8.4 4.2 135 10 129 165 4.2 0 4.3 4.3 02/09/2006 10:50:00 3.9 0.9 6.1 1.9 3.9 0.9 6.1 1.9 4.1 1 6.5 2.3 137 10 157 165 4.2 0 4.5 4.3 02/09/2006 11:00:00 2.7 0.5 3.8 1.1 2.7 0.5 3.8 1.1 2.8 0.5 4.6 1.5 126 12 114 165 4.4 0 4.5 4.3 02/09/2006 11:10:00 3.6 0.5 4.9 2.3 3.6 0.5 4.9 2.6 3.6 0.4 4.9 2.6 130 10 135 165 4.4 0 4.5 4.3 02/09/2006 11:20:00 2.5 0.6 3.8 1.5 2.5 0.6 3.8 1.5 2.5 0.5 3.8 1.1 140 8 132 165 4.3 0 4.5 4.3 02/09/2006 11:30:00 1.9 0.8 3.4 0.4 1.8 0.9 3.4 0.4 2.1 0.7 4.2 0.4 149 16 138 165 4.5 0 4.8 4.5 02/09/2006 11:40:00 2.5 0.7 3.8 1.1 2.4 0.6 3.8 0.7 2.4 0.5 3.4 1.1 152 9 154 165 4.4 0 4.8 4.3 02/09/2006 11:50:00 3.2 0.6 4.6 1.5 3 0.6 4.6 1.5 3.1 0.5 4.2 1.9 169 15 164 165 4.4 0.1 4.5 4 02/09/2006 12:00:00 3.7 0.4 5.3 2.6 3.5 0.4 4.9 2.6 3.6 0.5 4.9 2.3 156 10 164 165 4.1 0 4.3 4 02/09/2006 12:10:00 3.9 0.4 5.3 2.3 3.7 0.4 4.9 2.3 3.7 0.4 4.6 2.6 157 14 164 165 4.1 0 4.5 4 02/09/2006 12:20:00 3.5 0.4 4.6 2.3 3.3 0.4 4.2 2.3 3.4 0.4 4.6 2.3 167 6 164 165 4.3 0 4.5 4.3 02/09/2006 12:30:00 2.8 0.4 3.8 1.9 2.7 0.4 3.8 1.9 2.6 0.4 3.4 1.9 175 5 177 165 4.3 0 4.5 4.3 02/09/2006 12:40:00 3.2 0.6 4.2 1.9 3.1 0.5 4.2 1.9 3.1 0.5 4.2 2.3 170 4 173 165 4.4 0 4.8 4.3 02/09/2006 12:50:00 2.9 0.7 4.6 1.5 2.8 0.6 4.2 1.5 3 0.6 4.6 1.9 170 6 157 165 4.4 0 4.8 4.3 02/09/2006 13:00:00 4.2 0.4 4.9 3.4 4 0.3 4.9 3.4 4.1 0.4 5.3 3.4 162 6 176 165 3.8 0.2 4.3 3.5 02/09/2006 13:10:00 4.1 0.5 5.3 3 4 0.5 4.9 3 4.1 0.5 5.3 3 167 10 169 165 3.9 0 4 3.5 02/09/2006 13:20:00 5.2 0.4 6.1 4.2 4.9 0.3 5.7 4.2 5 0.3 5.7 4.2 166 11 169 165 4 0.1 4.3 3.8 02/09/2006 13:30:00 6 0.9 10.3 4.2 5.8 0.8 9.5 3.8 5.7 0.6 7.6 4.2 164 7 162 165 3.9 0 4.5 3.5 02/09/2006 13:40:00 6.3 0.6 8.4 4.6 6 0.6 7.6 4.6 5.9 0.6 8 4.2 161 7 176 165 4 0 4.3 3.8 02/09/2006 13:50:00 6.3 0.6 8 4.9 6 0.6 7.6 4.6 6.1 0.6 8 4.9 166 7 162 165 4 0 4.3 3.8 02/09/2006 14:00:00 6.4 1 8.4 4.2 6.1 0.9 8.4 4.2 6.4 0.9 8.4 4.2 166 6 166 165 4 0 4.3 3.8 02/09/2006 14:10:00 5.8 0.6 7.2 4.6 5.6 0.6 6.8 4.6 5.8 0.6 7.2 4.6 160 8 164 165 3.8 0 4 3.5 02/09/2006 14:20:00 7.2 0.8 8.8 5.3 6.9 0.7 8.8 4.9 7.1 0.7 9.1 5.7 160 15 165 165 3.5 0 3.8 3.3 02/09/2006 14:30:00 7.7 0.8 9.5 5.7 7.4 0.8 9.5 5.7 7.8 0.7 9.9 5.7 156 6 155 165 3 0.1 3.3 2.8 02/09/2006 14:40:00 6.9 0.7 9.1 4.6 6.6 0.7 8.8 4.6 6.9 0.6 8.4 5.3 167 11 161 165 3.1 0 3.3 2.8 02/09/2006 14:50:00 6.6 1 10.7 4.9 6.4 1 10.3 4.9 6.5 0.9 9.9 4.9 178 9 186 165 3.3 0 3.5 3 02/09/2006 15:00:00 7.2 0.9 9.5 5.3 7.2 1 9.5 4.9 7.2 1 9.1 4.6 189 10 200 165 3.3 0 3.5 3.3 02/09/2006 15:10:00 9.2 1 11.5 6.8 9.3 1 11.8 6.8 9.3 1.1 11.8 5.3 203 6 207 165 3 0 3.3 2.8 02/09/2006 15:20:00 8.8 1.1 11.5 5.7 8.8 1.1 11.8 6.1 8.9 1.1 11.5 6.5 197 8 206 165 2.9 0 3 2.8 02/09/2006 15:30:00 7.9 0.9 9.9 6.1 7.8 0.8 9.9 6.1 8 1 10.7 5.7 187 9 183 165 2.9 0 3 2.8 02/09/2006 15:40:00 10.2 0.8 12.2 7.2 10.1 0.8 12.2 6.8 10.4 1 12.6 7.6 189 5 193 165 2.7 0 2.8 2.6 02/09/2006 15:50:00 10.8 1.1 15.3 8.4 10.9 1.1 15.3 8 11.1 1.1 14.9 8.4 194 5 196 165 2.6 0.1 2.8 2.6 02/09/2006 16:00:00 10.2 1 13 7.6 10.1 1 12.6 7.6 10.5 1.1 13 7.6 190 6 182 165 2.4 0 2.6 2.3 02/09/2006 16:10:00 7.9 0.8 11.1 4.9 8 0.8 10.7 4.9 8.1 0.9 10.3 4.9 201 9 204 165 2.4 0 2.6 2.3 02/09/2006 16:20:00 8.8 1.8 12.6 4.9 8.8 1.9 13 4.9 8.9 1.9 13 4.9 199 9 211 165 2.5 0 2.6 2.3 02/09/2006 16:30:00 10 1 12.6 7.2 10.2 1.1 12.6 7.2 10.1 1.2 13 6.8 207 6 201 165 2.7 0.1 3 2.6 02/09/2006 16:40:00 7.8 1.5 11.5 3.4 7.9 1.5 11.5 3.8 7.8 1.3 11.5 4.6 201 9 194 165 2.9 0 3 2.8 02/09/2006 16:50:00 8.5 2.2 13 4.9 8.5 2.2 13 4.9 8.6 2.3 13 4.6 195 11 199 165 2.7 0.1 3 2.3 02/09/2006 17:00:00 11.8 1.7 15.3 7.6 11.7 1.8 15.3 7.6 11.9 2 15.3 6.8 190 7 186 165 2.4 0 2.6 2.3 02/09/2006 17:10:00 11.8 0.9 14.1 9.1 11.8 0.8 14.1 8.8 11.8 1.1 14.5 8.8 191 5 196 165 2.3 0 2.6 2.1 02/09/2006 17:20:00 10.1 1 13 7.6 9.8 1 12.6 7.2 10.2 1.1 13 8 181 8 186 165 2.1 0.1 2.3 1.8 02/09/2006 17:30:00 12.9 1.2 16.1 9.5 12.5 1.1 15.3 9.1 12.9 1.1 16.4 9.9 176 5 183 165 1.8 0 2.1 1.6 02/09/2006 17:40:00 13.6 0.9 16.1 11.1 13.1 0.8 14.9 10.7 13.6 0.9 16.1 11.1 175 5 179 165 1.8 0 1.8 1.6 02/09/2006 17:50:00 14.4 1.4 17.6 11.5 14 1.4 17.2 10.7 14.5 1.5 18.3 11.8 172 9 164 165 1.7 0 1.8 1.6 02/09/2006 18:00:00 15.6 1 17.6 12.6 15.2 0.9 16.8 12.2 16.1 1 18.3 12.6 169 9 166 165 1.7 0 1.8 1.4 02/09/2006 18:10:00 15.6 0.9 17.6 13 15.1 0.9 17.2 12.6 15.8 0.9 17.9 13.3 168 5 167 165 1.7 0 1.8 1.6 02/09/2006 18:20:00 14.9 1 17.9 12.2 14.5 1 17.2 12.2 15.1 1 17.6 12.2 166 5 166 165 1.6 0 1.8 1.4 02/09/2006 18:30:00 13 1.3 15.6 8.8 12.5 1.3 14.9 8.4 13.1 1.4 16.1 9.5 171 2 169 165 1.7 0 1.8 1.4 02/09/2006 18:40:00 10.2 1.1 13 8 9.9 1 13 7.6 10.2 1.2 12.6 7.6 173 1 173 165 1.7 0 1.8 1.6 02/09/2006 18:50:00 12.7 1 15.3 9.9 12.3 1 14.9 9.9 12.7 1 15.3 9.9 166 2 165 165 1.7 0 1.8 1.6 02/09/2006 19:00:00 13.1 0.8 14.9 10.7 12.7 0.7 14.1 10.3 13.3 0.8 14.9 10.3 169 3 175 165 1.8 0 1.8 1.6 02/09/2006 19:10:00 13.2 0.6 14.5 11.5 12.7 0.6 14.1 11.1 13.3 0.8 15.3 11.1 170 2 174 165 1.8 0 1.8 1.6 02/09/2006 19:20:00 11.7 0.7 13.7 9.9 11.3 0.6 13 9.5 12 0.7 13.3 10.3 167 0 167 165 1.8 0 1.8 1.6 02/09/2006 19:30:00 10.4 0.7 12.2 8.4 10.1 0.6 11.8 8 10.5 0.7 12.2 9.1 164 1 164 165 1.7 0 1.8 1.6 02/09/2006 19:40:00 10.4 0.7 12.6 8.8 10.2 0.7 12.2 8.8 10.6 0.7 13 9.1 161 1 161 165 1.7 0 1.8 1.6 02/09/2006 19:50:00 12.1 0.5 13 10.3 12 0.5 13.3 9.9 12.2 0.6 13.3 10.3 152 1 152 165 1.8 0 1.8 1.8 02/09/2006 20:00:00 13.6 0.8 15.6 11.5 13.5 0.7 15.6 11.1 13.6 1 16.1 10.7 152 1 151 165 1.8 0 1.8 1.8 02/09/2006 20:10:00 14.5 0.6 15.6 13 14.4 0.6 15.6 12.2 14.6 0.7 16.4 12.2 152 1 153 165 1.9 0 1.8 1.8 02/09/2006 20:20:00 14.4 0.8 16.1 12.2 14.3 0.8 16.4 12.2 14.5 0.9 16.4 11.8 151 3 150 165 1.9 0 1.8 1.8 02/09/2006 20:30:00 14.7 0.8 16.4 13 14.8 0.8 16.4 12.6 14.8 1 16.8 12.2 150 3 146 165 1.9 0 1.8 1.8 02/09/2006 20:40:00 15.2 0.9 16.8 12.2 15.3 0.9 16.8 12.2 15.2 1 17.2 12.2 149 3 151 165 1.9 0 2.1 1.8 02/09/2006 20:50:00 13.8 1.1 16.8 10.7 13.9 1.1 16.8 10.7 13.6 1.3 16.4 9.9 149 4 148 165 1.9 0 1.8 1.8 02/09/2006 21:00:00 15 1.2 17.6 12.6 15.1 1.2 17.6 12.6 14.8 1.5 17.9 10.7 149 4 151 165 1.9 0 2.1 1.8 02/09/2006 21:10:00 15.8 0.8 17.6 13 15.8 0.8 17.9 13 15.7 1 17.6 11.1 150 3 148 165 2 0 2.1 1.8 02/09/2006 21:20:00 15.9 1 17.9 13.3 15.9 0.9 17.9 13.3 15.8 1.2 18.3 12.2 150 3 148 165 2 0 2.1 1.8 02/09/2006 21:30:00 16 0.9 18.7 13 16 0.9 18.3 13 16 1.2 18.7 12.2 150 4 147 165 2 0 2.3 1.8 02/09/2006 21:40:00 16.4 1.1 19.1 13 16.3 1.1 19.1 13 16.3 1.2 19.5 13 149 3 151 165 2 0 2.3 1.8 02/09/2006 21:50:00 16.5 1.2 19.5 13.7 16.4 1.2 19.5 13.7 16.4 1.4 20.2 13.3 151 4 145 165 2 0 2.3 1.8 02/09/2006 22:00:00 16.5 1.2 18.7 13 16.4 1.1 18.7 13.3 16.4 1.3 19.1 11.8 150 3 153 165 2.1 0 2.3 1.8 02/09/2006 22:10:00 16.5 1.3 19.9 13 16.5 1.3 19.1 13 16.4 1.4 19.5 12.6 148 3 152 165 2 0 2.3 1.8 02/09/2006 22:20:00 18.2 1.1 20.2 14.5 18.2 1.1 20.2 14.5 18.2 1.3 20.6 13.7 148 3 144 165 2.1 0 2.3 2.1 02/09/2006 22:30:00 18.7 0.9 20.6 15.6 18.7 0.9 21 15.6 18.5 1.1 21 15.3 146 3 147 165 2 0 2.3 1.8 02/09/2006 22:40:00 18.6 1 20.6 15.3 18.5 1 20.6 15.3 18.7 1.1 20.6 14.9 149 3 149 165 2 0 2.3 1.8 02/09/2006 22:50:00 18.8 1.2 21.8 14.9 18.7 1.2 21.8 14.9 18.7 1.3 21.8 13.7 148 3 148 165 2 0 2.3 1.8 02/09/2006 23:00:00 18 1.6 21.4 13.7 17.9 1.5 21 14.1 17.9 1.9 21.8 10.7 149 3 150 165 2 0 2.1 1.8 02/09/2006 23:10:00 16.9 0.9 19.1 14.1 16.9 0.8 18.7 14.1 17 1 19.1 13 148 4 140 165 2 0 2.1 1.8 02/09/2006 23:20:00 16.3 0.9 18.3 13.3 16.3 0.9 18.3 13.3 16.1 1.2 18.7 12.2 148 4 144 165 2 0 2.1 1.8 02/09/2006 23:30:00 18.4 1.4 21.4 14.5 18.4 1.4 21.4 14.5 18.5 1.6 22.1 13 146 4 147 165 2.1 0 2.3 1.8 02/09/2006 23:40:00 17.7 1.5 21 13.7 17.7 1.5 21 13.7 17.5 1.7 20.6 13.3 149 4 149 165 2 0 2.3 1.8 02/09/2006 23:50:00 16.1 1.1 18.7 13.3 16 1.1 18.7 13.3 15.9 1.2 19.1 12.2 149 4 149 165 2 0 2.3 1.8 02/10/2006 00:00:00 14.9 0.9 16.8 12.2 14.8 0.9 16.8 12.2 14.8 1.1 16.8 10.7 148 4 147 165 2 0 2.3 1.8 02/10/2006 00:10:00 15.6 1.2 17.9 12.2 15.7 1.1 17.9 11.8 15.6 1.3 18.3 11.1 143 5 144 165 2.1 0 2.3 1.8 02/10/2006 00:20:00 14.3 1.5 17.9 11.5 14.3 1.5 18.3 11.5 14.4 1.5 18.3 11.1 148 8 145 165 1.9 0.3 2.3 1.4 02/10/2006 00:30:00 12.2 0.8 14.1 9.9 12.1 0.8 14.1 9.9 12.4 0.8 14.5 10.3 152 6 153 165 1.4 0 1.6 1.4 02/10/2006 00:40:00 15.3 1.2 18.7 12.2 15.3 1.2 18.3 11.8 15.4 1.2 18.3 11.8 150 6 157 165 1.4 0.1 1.6 1.4 02/10/2006 00:50:00 13.7 1 15.6 11.5 13.8 1 15.6 11.5 13.8 1.1 16.1 10.3 145 5 149 165 1.4 0 1.6 1.4 02/10/2006 01:00:00 13 1.3 16.4 8.8 13.2 1.3 16.8 9.1 12.8 1.3 16.1 9.1 137 7 132 165 1.4 0 1.6 1.4 02/10/2006 01:10:00 13.3 1.2 15.6 9.1 13.5 1.2 16.1 9.1 13.6 1.3 16.4 9.9 141 5 140 165 1.4 0 1.6 1.4 02/10/2006 01:20:00 15.4 1.6 19.1 11.1 15.5 1.5 19.9 11.8 15.5 1.6 19.1 11.1 142 6 141 165 1.5 0 1.6 1.4 02/10/2006 01:30:00 16.9 1.4 20.2 13.7 16.8 1.5 19.9 13 16.6 1.5 20.2 12.6 145 6 145 165 1.4 0.1 1.6 1.1 02/10/2006 01:40:00 12.6 1.6 17.6 9.1 12.5 1.6 17.6 9.1 12.4 1.7 17.2 8.8 141 6 145 165 1.1 0 1.4 0.9 02/10/2006 01:50:00 13.6 1.3 16.8 9.5 13.5 1.3 16.8 9.5 13.2 1.6 16.4 8.8 142 7 138 165 1.4 0 1.6 1.4 02/10/2006 02:00:00 11.2 1.5 15.3 8 11.1 1.5 15.3 8 11.1 1.5 15.3 7.6 143 6 146 165 1.6 0 1.8 1.4 02/10/2006 02:10:00 11.3 2.3 16.1 7.2 11.4 2.3 16.1 7.2 11 2.3 16.8 6.5 131 9 126 165 1.8 0.1 1.8 1.6 02/10/2006 02:20:00 18.2 2 22.9 12.2 18.1 2 22.6 13 17.8 2.3 22.9 11.1 137 6 145 165 1.7 0.1 1.8 1.4 02/10/2006 02:30:00 15.4 1.7 19.5 11.8 15.3 1.7 19.5 11.5 14.9 2 19.9 11.1 138 7 145 165 1.3 0 1.6 1.4 02/10/2006 02:40:00 12.6 1 14.9 9.5 12.5 1 14.9 10.3 12.4 1.1 15.3 9.1 135 4 133 165 1.4 0 1.6 1.4 02/10/2006 02:50:00 12.1 1.5 15.3 7.6 12 1.5 14.9 8 11.9 1.5 14.9 8 133 1 133 165 1.5 0 1.6 1.4 02/10/2006 03:00:00 13.3 1.9 17.6 8.8 13.2 1.8 17.6 9.1 13.2 2.1 18.3 8.8 137 6 138 165 1.5 0 1.6 1.4 02/10/2006 03:10:00 12.3 1 14.5 9.9 12.2 1 14.5 9.9 12.1 1 15.3 8.8 141 0 141 165 1.5 0 1.6 1.4 02/10/2006 03:20:00 11.9 1.3 14.9 8 11.8 1.3 14.9 8 11.7 1.6 14.9 6.8 141 0 141 165 1.5 0 1.8 1.4 02/10/2006 03:30:00 12.4 0.9 14.5 8.8 12.2 0.9 14.5 8.8 12.1 1 14.5 9.1 141 0 141 165 1.6 0 1.6 1.6 02/10/2006 03:40:00 11.7 1.2 15.3 9.1 11.6 1.2 15.3 8.8 11.4 1.3 15.6 8.8 141 0 141 165 1.6 0 1.6 1.6 02/10/2006 03:50:00 13.2 0.9 16.1 11.1 13.4 0.9 16.1 11.1 13.2 1 15.3 9.9 141 0 141 165 1.6 0 1.6 1.6 02/10/2006 04:00:00 11.2 1 14.1 8 11.2 1 14.1 8 11.2 1.2 14.5 7.6 141 0 141 165 1.6 0 1.6 1.4 02/10/2006 04:10:00 12.4 1.5 16.1 9.1 12.4 1.4 16.1 9.5 12.3 1.7 16.8 8.8 141 0 141 165 1.6 0 1.6 1.6 02/10/2006 04:20:00 11.5 1.1 14.5 9.1 11.6 1.1 14.5 9.1 11.6 1.1 14.5 8.8 141 0 141 165 1.6 0 1.6 1.6 02/10/2006 04:30:00 11.3 0.9 14.1 9.1 11.5 0.9 14.1 9.1 11.4 1 13.3 8.8 140 0 141 165 1.6 0 1.8 1.6 02/10/2006 04:40:00 12.4 1.5 15.3 8.8 12.5 1.3 15.3 8.8 12.4 1.5 15.6 8.8 140 0 141 165 1.7 0 1.6 1.6 02/10/2006 04:50:00 11.9 0.9 13.7 9.5 11.8 0.9 13.7 9.5 12 1 14.1 9.5 141 0 141 165 1.7 0 1.8 1.6 02/10/2006 05:00:00 10.6 1 13 8 10.6 1 13 8 10.8 1 13.3 8 140 0 141 165 1.7 0 1.8 1.6 02/10/2006 05:10:00 12.1 1 14.5 9.9 12 1 14.5 9.5 12.3 1.2 15.3 9.1 140 0 141 165 1.7 0 1.8 1.6 02/10/2006 05:20:00 13.7 1.2 16.4 10.3 13.5 1.2 16.4 10.3 14.2 1.4 17.2 10.3 140 0 140 165 1.9 0 1.8 1.8 02/10/2006 05:30:00 14.3 0.6 16.1 12.2 14.1 0.6 16.1 12.2 14.9 0.7 16.4 13 140 0 140 165 1.9 0 1.8 1.8 02/10/2006 05:40:00 14.3 1 16.4 11.8 14.1 1 16.4 11.1 14.4 0.9 16.4 12.2 140 0 141 165 2 0 2.3 1.8 02/10/2006 05:50:00 14.9 0.7 16.4 13 14.5 0.7 16.4 13 14.5 0.9 16.8 12.2 140 0 141 165 2.2 0 2.3 2.1 02/10/2006 06:00:00 14 0.8 15.6 11.8 13.5 0.7 15.3 11.5 13.8 0.9 16.1 11.5 142 1 141 165 2.3 0 2.3 2.3 02/10/2006 06:10:00 13.9 1 16.8 11.5 13.6 1 17.2 11.1 13.8 1.1 17.9 11.1 144 4 149 165 2.3 0 2.6 2.3 02/10/2006 06:20:00 15.8 1.5 18.7 12.2 15.7 1.5 19.1 12.2 16.4 1.9 19.9 12.2 154 4 156 165 1.9 0.1 2.6 1.6 02/10/2006 06:30:00 13.5 1 15.6 10.7 13.3 1 15.3 10.3 13.7 1.1 16.1 11.1 151 3 150 165 1.7 0 1.8 1.6 02/10/2006 06:40:00 13.1 0.8 15.3 11.1 13.1 0.8 14.9 10.7 13.6 1 15.6 9.5 154 4 154 165 1.9 0 2.1 1.8 02/10/2006 06:50:00 13.2 1.3 16.4 9.5 12.7 1.1 15.6 9.5 13.1 1.3 16.4 9.9 158 15 161 165 1.9 0 2.1 1.8 02/10/2006 07:00:00 13.8 0.8 15.6 11.1 13.1 0.9 15.3 10.7 13.3 1 15.3 10.7 153 4 162 165 1.9 0 2.1 1.8 02/10/2006 07:10:00 12.9 1.7 16.8 9.1 12.4 1.7 16.1 8.8 12.6 1.7 16.8 8.8 151 6 145 165 1.9 0 2.1 1.8 02/10/2006 07:20:00 14.5 1 17.2 11.8 13.9 1 16.8 11.5 14.1 1.1 16.4 10.7 155 9 147 165 1.9 0 2.3 1.8 02/10/2006 07:30:00 13.8 0.8 16.1 11.5 13.2 0.8 15.3 11.1 13.7 0.8 15.6 11.5 153 5 156 165 1.9 0 2.1 1.8 02/10/2006 07:40:00 14.1 1 16.8 11.5 13.5 1 16.1 10.7 13.8 1.1 16.4 10.3 157 7 157 165 1.9 0 2.1 1.8 02/10/2006 07:50:00 14.4 1 16.8 11.8 13.9 1 16.4 11.1 14.4 1.1 16.8 11.5 156 9 157 165 1.9 0 2.1 1.8 02/10/2006 08:00:00 14.1 1.1 16.4 11.5 13.7 1 15.6 10.7 14.3 1 16.8 11.8 158 11 158 165 1.9 0 1.8 1.8 02/10/2006 08:10:00 11.8 1 14.1 9.5 11.3 1 13.7 9.1 11.8 1 14.1 9.1 160 9 158 165 1.9 0 2.1 1.8 02/10/2006 08:20:00 11.1 0.8 13 9.1 10.8 0.7 13 8.8 11.2 0.7 13.3 9.5 161 10 162 165 1.9 0 2.3 1.8 02/10/2006 08:30:00 11.6 1 14.5 9.1 11.4 1 14.1 8.8 11.8 0.9 14.5 9.5 158 5 153 165 1.9 0 1.8 1.8 02/10/2006 08:40:00 11.2 1 14.1 8.8 11 0.9 13.3 8.8 11 1 13.3 8.8 161 14 162 165 1.8 0 1.8 1.8 02/10/2006 08:50:00 12.2 1.1 15.3 9.9 12 1.1 15.3 9.9 12.4 1.2 15.3 9.5 162 10 155 165 1.7 0 1.8 1.6 02/10/2006 09:00:00 12.3 0.9 14.9 9.9 12.2 0.9 14.9 9.9 12.5 1.1 15.3 9.1 156 5 155 165 1.5 0 1.8 1.4 02/10/2006 09:10:00 12.2 1 14.1 9.5 12.1 1 14.1 9.5 12.4 1 14.1 9.5 155 5 146 165 1.2 0 1.6 0.9 02/10/2006 09:20:00 11 1 13.3 8.8 10.8 1 13 8.8 11 1 13.7 9.1 154 0 154 165 0.9 0 1.4 0.9 02/10/2006 09:30:00 9.8 0.4 10.7 8.8 9.7 0.4 10.7 8.4 9.9 0.5 11.1 8.8 154 0 154 165 0.9 0 1.1 0.9 02/10/2006 09:40:00 9.3 0.4 10.3 8 9.1 0.4 10.3 8 9.3 0.5 10.7 7.2 154 0 154 165 0.9 0 1.1 0.9 02/10/2006 09:50:00 8.6 0.5 9.9 6.5 8.3 0.5 9.5 6.1 8.6 0.5 9.9 7.2 154 0 154 165 0.9 0 1.4 0.9 02/10/2006 10:00:00 8 0.6 9.5 6.5 7.6 0.6 9.1 6.1 8 0.6 9.5 6.8 154 0 154 165 0.8 0 0.9 0.9 02/10/2006 10:10:00 8 0.9 10.7 6.5 7.6 0.8 10.3 6.1 7.7 0.7 9.5 5.7 154 0 154 165 0.9 0 1.1 0.9 02/10/2006 10:20:00 8.8 1 11.8 6.8 8.4 0.9 11.1 6.8 8.6 0.9 11.5 6.5 154 0 154 165 1.1 0 1.4 0.9 02/10/2006 10:30:00 11.5 0.7 13 9.5 10.9 0.6 12.2 9.1 11.4 0.7 13 9.1 154 0 154 165 1.5 0 1.6 1.4 02/10/2006 10:40:00 12.5 1 14.9 10.3 12 1 14.5 9.9 12.4 1.1 15.3 10.3 157 1 158 165 1.7 0 1.8 1.6 02/10/2006 10:50:00 14.6 0.8 16.8 12.2 14 0.7 15.6 11.5 14.6 1 16.8 11.8 161 1 162 165 1.7 0 1.8 1.6 02/10/2006 11:00:00 14.3 1.1 16.8 11.8 13.7 1 16.1 11.1 14.4 1.2 17.6 11.5 162 0 162 165 1.6 0 1.8 1.6 02/10/2006 11:10:00 11.4 0.9 13.7 9.5 10.9 0.8 13.3 9.1 11.5 0.9 14.5 8.8 162 0 162 165 1.5 0 1.8 1.4 02/10/2006 11:20:00 8.6 1.2 11.5 6.1 8.3 1.1 11.1 6.1 8.7 1.3 11.8 6.1 162 0 162 165 1.6 0 1.6 1.6 02/10/2006 11:30:00 8.8 1.1 11.1 5.7 8.6 1 10.7 5.7 8.9 1 11.5 6.1 162 0 162 165 1.6 0 1.6 1.6 02/10/2006 11:40:00 12.7 1.3 16.1 9.9 12.1 1.3 15.6 9.5 12.7 1.2 16.4 10.3 162 0 162 165 1.7 0 1.8 1.6 02/10/2006 11:50:00 13.2 0.8 15.3 10.7 12.8 1 14.9 9.9 13.6 1.2 15.6 9.5 168 9 167 165 1.8 0.1 2.1 1.6 02/10/2006 12:00:00 12.6 1.2 16.8 9.1 12.3 1.2 16.8 9.1 13.3 1.3 17.9 10.3 170 8 178 165 2 0.1 2.3 1.8 02/10/2006 12:10:00 12.5 1.2 16.8 10.3 12.1 1.2 16.8 9.9 13.1 1.3 17.9 10.7 173 9 217 165 2.4 0.1 2.8 2.1 02/10/2006 12:20:00 10.1 0.9 12.2 7.6 10 0.8 11.8 7.6 10.7 1 12.6 8 175 7 166 165 2.6 0.2 3 2.3 02/10/2006 12:30:00 13.2 1.9 17.6 9.1 12.8 1.8 16.8 9.1 13.6 2.1 19.5 9.1 171 6 171 165 2.4 0.4 3.3 1.8 02/10/2006 12:40:00 11.1 1 13.3 8.4 10.7 1 13 8.4 11.4 1.1 14.1 8.8 174 6 175 165 2.3 0 2.6 2.1 02/10/2006 12:50:00 12.8 2.2 17.9 9.1 12.3 2.1 17.2 8.8 13 2.2 18.7 9.1 171 13 168 165 2.4 0 2.8 2.3 02/10/2006 13:00:00 14.6 1 17.2 11.5 14 0.9 16.4 11.1 14.6 1 17.2 11.8 171 9 173 165 2.9 0.1 3 2.6 02/10/2006 13:10:00 15.1 1.2 17.9 11.1 14.4 1.2 17.2 10.7 15 1.3 18.3 11.5 174 9 176 165 3.1 0 3.3 2.8 02/10/2006 13:20:00 15.3 1.3 19.5 11.8 14.6 1.3 18.7 11.1 15.3 1.4 19.5 11.8 174 6 170 165 2.9 0.2 3.3 2.6 02/10/2006 13:30:00 18 1 19.9 15.3 17.4 1 19.5 14.9 18 1.1 20.2 14.1 172 6 166 165 2.6 0 2.8 2.6 02/10/2006 13:40:00 18.1 1.3 21.4 14.5 17.6 1.2 20.6 14.1 18.4 1.3 21.8 14.5 172 5 171 165 2.8 0 3 2.6 02/10/2006 13:50:00 18.6 1.2 22.1 15.3 18 1.1 21 14.5 19 1.3 21.8 15.3 174 11 172 165 2.9 0.1 3 2.6 02/10/2006 14:00:00 17.8 1.7 21.8 14.1 17.3 1.7 21.8 13.7 18 1.8 22.9 14.1 172 12 167 165 2.6 0.2 3 1.8 02/10/2006 14:10:00 18.4 1.4 21.8 14.5 17.8 1.3 21.4 14.1 18.5 1.6 22.1 14.1 173 11 184 165 2.4 0.3 3 1.8 02/10/2006 14:20:00 17.1 1.1 19.5 13.3 16.5 1 18.7 13 17.4 1.2 20.2 13.3 171 9 167 165 3 0 3.3 2.8 02/10/2006 14:30:00 19.2 1.1 22.1 15.6 18.6 1 21.4 15.3 19.4 1.3 23.3 15.3 174 5 182 165 3 0.1 3.3 2.8 02/10/2006 14:40:00 18.1 1.5 21.8 14.1 17.6 1.5 21.4 14.1 18.4 1.6 22.1 14.1 173 7 165 165 2.9 0 3.3 2.8 02/10/2006 14:50:00 18.4 1.6 21.4 14.1 17.8 1.5 20.6 13.3 18.7 1.5 21.8 15.3 174 5 177 165 2.7 0 2.8 2.6 02/10/2006 15:00:00 16.8 1.2 20.2 13.3 16.3 1.1 19.9 13 17.1 1.3 21 13 171 8 166 165 2.9 0.1 3.3 2.6 02/10/2006 15:10:00 17.2 1 19.5 13.7 16.7 1 19.1 13.3 17.5 1.1 19.9 12.6 169 10 165 165 2.9 0 3 2.6 02/10/2006 15:20:00 18.1 1.1 21.4 14.5 17.6 1.1 21 13.7 18.4 1.2 22.1 15.6 169 11 164 165 2.9 0 3 2.6 02/10/2006 15:30:00 18.1 1.3 22.1 15.3 17.5 1.2 21 14.9 18.4 1.3 22.6 15.6 172 5 177 165 2.6 0.1 2.8 2.3 02/10/2006 15:40:00 18.1 1.1 21 14.9 17.5 1 21 14.9 18.3 1.1 21 14.5 173 8 179 165 2.3 0 2.6 2.1 02/10/2006 15:50:00 17.7 1.2 21 14.9 17.2 1.1 20.6 14.5 17.9 1.3 22.1 14.5 170 9 181 165 2.3 0 2.6 2.1 02/10/2006 16:00:00 17.6 1.1 21 14.9 17 1 19.9 14.9 17.8 1.1 21 14.5 175 6 177 165 2 0.1 2.3 1.8 02/10/2006 16:10:00 16.2 1.4 18.7 11.8 15.6 1.3 17.9 11.8 16.5 1.4 19.1 11.8 174 6 173 165 2 0 2.3 1.8 02/10/2006 16:20:00 15 1.7 19.1 10.7 14.6 1.5 18.3 11.1 15.2 1.6 18.7 11.1 179 6 180 165 1.9 0 2.1 1.8 02/10/2006 16:30:00 16.2 1.1 18.7 13.7 15.7 1 17.9 13 16.4 1.2 19.1 13 177 5 175 165 2.1 0 2.3 1.8 02/10/2006 16:40:00 15 1 16.8 12.6 14.4 0.9 16.4 12.2 15.3 1.1 17.2 12.2 173 6 179 165 2.2 0 2.3 2.1 02/10/2006 16:50:00 16.7 1 19.5 14.1 16.2 0.9 18.7 13.7 17.1 1 20.2 13.7 174 5 172 165 2.3 0 2.6 2.3 02/10/2006 17:00:00 16.4 0.9 19.1 14.1 15.8 0.8 18.3 13.7 16.8 1 19.1 14.1 173 5 170 165 2.3 0 2.6 2.3 02/10/2006 17:10:00 15.7 1 18.3 12.6 15.2 1 17.6 11.8 16.1 1 19.1 12.6 175 6 181 165 2.3 0 2.6 2.3 02/10/2006 17:20:00 16.9 1 19.5 14.1 16.3 0.9 18.7 13.3 17.2 0.9 19.9 14.5 175 5 178 165 2.3 0 2.6 2.3 02/10/2006 17:30:00 16.4 1 18.3 13.7 15.8 1 17.9 13.7 16.6 1.1 19.1 13.7 175 8 178 165 2.3 0 2.3 2.1 02/10/2006 17:40:00 15.8 1 18.3 13.7 15.3 0.9 17.6 13 16.1 0.9 19.1 14.1 175 5 176 165 2.3 0 2.3 2.1 02/10/2006 17:50:00 13.5 0.7 15.3 11.8 13 0.6 14.9 11.1 13.8 0.8 15.6 10.7 175 5 183 165 2.1 0 2.3 1.8 02/10/2006 18:00:00 12.3 0.7 14.1 10.7 11.9 0.6 13.3 10.3 12.5 0.8 14.1 9.9 169 5 168 165 2.1 0 2.3 1.8 02/10/2006 18:10:00 10.8 0.7 12.6 9.5 10.5 0.7 12.2 9.5 10.9 0.8 13 9.1 166 13 165 165 2 0 2.3 1.8 02/10/2006 18:20:00 10.9 1 13 8.8 10.7 1 12.6 8.8 11 1 13 8 158 4 159 165 2 0 2.3 1.8 02/10/2006 18:30:00 12 0.8 14.1 9.5 11.8 0.8 14.1 9.5 12.3 0.8 15.3 9.9 159 5 163 165 2.2 0 2.3 2.1 02/10/2006 18:40:00 12.2 0.8 14.1 9.9 12 0.8 14.1 9.9 12.5 0.9 14.5 9.9 163 7 162 165 2.2 0 2.6 2.1 02/10/2006 18:50:00 12.1 0.6 13.3 9.5 11.6 0.5 13 9.5 12.3 0.8 13.7 9.5 176 3 176 165 1.9 0 2.3 1.8 02/10/2006 19:00:00 10.3 0.8 11.8 8.4 10 0.7 11.5 8 10.5 0.8 12.2 8 179 5 182 165 1.6 0 1.8 1.4 02/10/2006 19:10:00 10.2 0.8 11.8 7.2 9.8 0.7 11.5 7.2 10.1 0.7 11.8 7.6 178 5 169 165 1.4 0 1.6 1.4 02/10/2006 19:20:00 8.2 0.8 10.7 6.5 7.9 0.8 9.9 6.1 8.2 0.9 10.3 6.5 174 5 169 165 1.4 0 1.6 1.1 02/10/2006 19:30:00 7.3 0.6 8.4 5.3 7.1 0.5 8 5.3 7.2 0.6 8.8 5.3 172 12 168 165 1.4 0 1.4 1.4 02/10/2006 19:40:00 7.4 0.6 8.8 5.7 7.2 0.5 8.4 5.3 7.3 0.6 8.4 5.3 166 5 172 165 1.4 0 1.6 1.4 02/10/2006 19:50:00 7.1 0.7 8.8 5.3 7.1 0.7 8.8 5.7 7.1 0.8 9.1 5.3 156 7 160 165 1.4 0 1.6 1.4 02/10/2006 20:00:00 7.7 0.7 9.1 6.1 7.6 0.7 9.5 6.1 7.7 0.7 9.5 5.7 160 14 147 165 1.7 0 1.8 1.4 02/10/2006 20:10:00 9.1 1.2 11.1 6.1 9.1 1.2 11.1 6.1 9.1 1.2 11.1 5.7 152 6 155 165 1.8 0.1 2.1 1.6 02/10/2006 20:20:00 10.6 0.7 12.2 8.8 10.6 0.7 12.2 8.8 10.5 0.9 12.6 8.4 151 3 149 165 2.1 0 2.3 1.8 02/10/2006 20:30:00 9.9 0.6 11.1 8 9.9 0.5 11.1 8 9.8 0.7 11.1 7.6 151 4 151 165 2.1 0 2.3 2.1 02/10/2006 20:40:00 10 0.6 12.2 8.8 9.9 0.6 11.8 8.8 10.1 0.6 11.8 8 153 4 156 165 2.1 0 2.3 2.1 02/10/2006 20:50:00 10 0.5 11.5 8.4 9.9 0.5 11.5 8.4 10 0.5 11.5 8.4 151 3 152 165 2.1 0 2.3 2.1 02/10/2006 21:00:00 10.2 0.6 11.8 8.8 10.2 0.5 11.5 8.8 10.2 0.6 11.8 8.4 148 3 149 165 2.1 0 2.3 2.1 02/10/2006 21:10:00 10.2 0.8 12.2 8 10.2 0.8 11.8 8.4 10.3 0.9 12.2 8.4 150 3 157 165 2.2 0 2.3 2.1 02/10/2006 21:20:00 10.6 1.7 14.5 8 10.5 1.7 14.5 8 10.7 1.7 15.3 7.6 149 4 156 165 2.2 0 2.3 2.1 02/10/2006 21:30:00 11.7 0.9 14.5 9.9 11.7 0.9 14.1 9.5 11.7 1.1 14.9 9.5 152 6 151 165 2 0 2.3 1.8 02/10/2006 21:40:00 12.7 1 15.3 9.9 12.6 1 15.3 10.3 12.7 1.1 15.6 9.9 151 4 158 165 2.1 0 2.3 1.8 02/10/2006 21:50:00 11.3 0.6 13.3 9.1 11.4 0.7 13.3 9.1 11.4 0.7 13 8.8 149 5 147 165 2.2 0 2.3 2.1 02/10/2006 22:00:00 12 0.9 14.1 9.1 12.1 0.9 14.1 9.1 12 1 14.5 9.1 146 5 142 165 2.3 0 2.3 2.3 02/10/2006 22:10:00 10.3 0.9 12.2 8.4 10.3 1 12.2 8 10.4 1 13 8.4 151 6 148 165 2.3 0 2.6 2.3 02/10/2006 22:20:00 9.7 0.7 11.5 7.6 9.7 0.7 11.1 7.6 9.6 1 11.8 6.8 150 8 154 165 2.4 0 2.6 2.3 02/10/2006 22:30:00 8.8 1 11.1 6.5 8.6 1 11.1 6.5 8.8 1.1 11.1 5.7 158 10 153 165 2 0 2.3 1.8 02/10/2006 22:40:00 6.4 0.8 8.4 4.9 6.3 0.7 8 4.6 6.4 1.1 8.8 4.2 161 8 164 165 1.9 0 2.3 1.8 02/10/2006 22:50:00 5.3 0.5 6.5 4.2 5.3 0.5 6.5 4.2 5.2 0.5 6.5 3.8 147 10 162 165 2 0 2.3 1.8 02/10/2006 23:00:00 6.5 1 8.8 4.2 6.6 1 8.8 4.2 6.5 1 8.4 4.6 145 8 145 165 2.1 0 2.3 1.8 02/10/2006 23:10:00 7.1 0.6 8.8 5.7 7.1 0.6 8.8 5.7 7.1 0.6 8.4 5.3 140 6 142 165 2.4 0.1 2.6 2.3 02/10/2006 23:20:00 6.4 0.6 8 4.9 6.5 0.6 8 5.3 6.4 0.6 7.6 4.6 135 8 123 165 2.4 0 2.6 2.3 02/10/2006 23:30:00 6 0.5 7.2 4.9 6.1 0.5 7.6 4.6 5.8 0.6 7.6 3.8 124 5 122 165 2.3 0 2.6 2.3 02/10/2006 23:40:00 6.6 0.5 7.6 4.9 6.7 0.5 7.6 4.6 6.4 0.5 7.6 4.2 118 4 119 165 2.3 0 2.3 2.3 02/10/2006 23:50:00 5.7 0.4 6.8 4.6 5.9 0.4 7.2 4.9 5.6 0.5 6.8 4.2 117 3 119 165 2.3 0 2.3 2.3 02/11/2006 00:00:00 4.9 0.4 5.7 3.8 5.1 0.4 6.1 4.2 4.9 0.4 6.1 3.4 107 5 110 165 2.3 0 2.6 2.3 02/11/2006 00:10:00 4.2 0.6 5.7 3 4.4 0.6 5.7 3.4 4 0.6 5.3 2.6 98 4 103 165 2.3 0 2.3 2.3 02/11/2006 00:20:00 4.5 0.4 5.3 3 4.7 0.4 5.3 3.4 4.5 0.5 5.3 3.4 108 4 108 165 2.3 0 2.6 2.3 02/11/2006 00:30:00 4.8 0.3 5.3 3.4 5 0.3 5.7 3.4 4.6 0.4 5.7 3 106 4 106 165 2.3 0 2.6 2.3 02/11/2006 00:40:00 5.3 0.6 6.5 3.8 5.5 0.6 6.8 3.4 5 0.7 6.5 3 105 4 111 165 2.3 0 2.6 2.3 02/11/2006 00:50:00 5.9 0.4 6.8 4.2 6.1 0.4 6.8 4.6 5.9 0.4 6.8 4.6 97 8 98 165 2.4 0 2.6 2.3 02/11/2006 01:00:00 6.6 0.6 7.6 5.3 6.8 0.6 8 5.3 6.3 0.6 8 4.6 92 5 99 165 2.4 0 2.6 2.3 02/11/2006 01:10:00 7.1 0.7 8.4 4.9 7.3 0.7 8.8 4.6 6.9 0.8 8.8 4.2 87 5 90 165 2.4 0 2.6 2.3 02/11/2006 01:20:00 7.4 0.5 8.8 5.7 7.6 0.6 8.8 6.1 7.2 0.7 8.8 4.9 91 5 104 165 2.3 0 2.3 2.3 02/11/2006 01:30:00 7.2 0.5 8.4 5.7 7.3 0.5 8.4 5.7 6.8 0.6 8 5.3 89 5 87 165 2.3 0 2.3 2.3 02/11/2006 01:40:00 6.8 0.7 8.4 4.6 7 0.7 8.4 4.9 6.5 0.6 8 5.3 91 5 91 165 2.3 0 2.3 2.3 02/11/2006 01:50:00 6.1 0.8 8 4.2 6.2 0.8 8 4.2 5.9 0.8 7.6 3.4 88 6 88 165 2.2 0 2.3 2.3 02/11/2006 02:00:00 5.8 0.6 7.2 4.2 6 0.6 7.2 4.2 5.8 0.6 7.2 4.2 83 5 87 165 2.2 0 2.3 2.3 02/11/2006 02:10:00 4.7 0.8 6.8 1.9 4.8 0.9 6.8 2.3 4.6 0.8 6.1 1.9 69 9 75 165 2.2 0 2.3 2.1 02/11/2006 02:20:00 3.7 0.8 5.7 2.3 3.8 0.8 6.1 2.3 3.7 0.8 6.1 2.3 67 9 54 165 2.1 0 2.3 2.1 02/11/2006 02:30:00 3.9 0.6 5.7 2.6 4 0.6 6.1 2.3 4 0.7 6.1 2.6 67 11 60 165 2.1 0 2.3 2.1 02/11/2006 02:40:00 4.6 0.7 6.1 3 4.7 0.8 6.5 2.6 4.4 0.7 6.5 2.6 54 9 63 165 2.1 0 2.3 2.1 02/11/2006 02:50:00 4.1 0.6 5.7 2.6 4.2 0.6 5.7 2.6 3.9 0.5 4.9 2.6 48 6 44 165 2.1 0 2.3 2.1 02/11/2006 03:00:00 3.8 0.5 5.3 2.3 3.8 0.6 5.3 2.3 3.7 0.5 4.9 2.3 39 6 54 165 2.1 0 2.3 2.1 02/11/2006 03:10:00 3.7 0.3 4.6 3 3.8 0.3 4.6 3 3.8 0.3 4.6 3 33 4 33 165 2.1 0 2.3 1.8 02/11/2006 03:20:00 4.1 0.6 6.5 3 4.2 0.6 6.5 3 4.2 0.6 6.1 3 36 4 40 165 2.1 0 2.3 1.8 02/11/2006 03:30:00 4.2 0.5 5.3 3 4.2 0.5 5.3 3 4.3 0.5 5.3 3.4 34 4 35 165 2 0 2.3 1.8 02/11/2006 03:40:00 4.6 0.4 5.3 3.4 4 0.7 5.3 1.9 4.8 0.4 5.7 3 17 6 8 165 2 0 2.1 1.8 02/11/2006 03:50:00 4.4 0.5 6.1 3 3.6 0.5 5.3 1.9 4.5 0.5 6.1 3.4 13 5 3 165 1.9 0 2.1 1.8 02/11/2006 04:00:00 6.1 0.7 7.6 3.8 5.1 0.9 7.6 2.6 6.1 0.7 8 4.6 13 4 15 165 1.8 0 1.8 1.6 02/11/2006 04:10:00 6.1 0.8 8.4 4.2 5 0.9 7.2 2.3 6.2 0.8 8 4.6 14 7 12 165 1.8 0.1 1.8 1.6 02/11/2006 04:20:00 5.9 0.8 7.6 3.8 4.4 1 6.8 2.3 5.9 0.8 7.6 3.8 8 6 10 165 1.9 0 2.1 1.8 02/11/2006 04:30:00 6.9 0.5 8 5.3 4.3 0.8 6.8 3 6.9 0.5 8 5.7 5 4 7 165 1.9 0 2.1 1.8 02/11/2006 04:40:00 7 0.7 8.8 5.3 4.1 0.6 6.1 2.6 7 0.8 8.8 5.3 3 4 4 165 2 0 2.1 1.8 02/11/2006 04:50:00 6.7 0.7 8.4 4.9 4.7 1.1 7.6 2.6 6.7 0.6 8.4 4.9 7 6 9 165 2 0 2.3 1.8 02/11/2006 05:00:00 6.1 1.3 8.8 3.4 3.9 1.2 7.2 1.9 6.2 1.3 8.8 3.8 0 6 2 165 2.1 0 2.3 1.8 02/11/2006 05:10:00 4 0.6 6.1 2.6 3 0.9 5.7 1.5 4.1 0.5 5.3 3 352 9 13 165 2 0 2.3 1.8 02/11/2006 05:20:00 4.3 0.6 6.1 3 3.9 0.6 5.7 2.3 4.3 0.5 5.7 3.4 341 12 13 165 1.9 0 2.1 1.8 02/11/2006 05:30:00 6 0.6 8.8 3.8 5.9 0.8 8.8 3.4 6 0.7 9.5 4.2 339 7 351 165 1.9 0 1.8 1.8 02/11/2006 05:40:00 6 0.6 7.6 4.6 6 0.8 7.6 3 6 0.6 8 4.6 338 5 338 165 1.8 0 1.8 1.6 02/11/2006 05:50:00 5.8 0.6 7.6 4.6 5.8 0.7 8 4.2 5.9 0.6 7.6 4.6 336 6 343 165 1.7 0 1.8 1.6 02/11/2006 06:00:00 6 0.7 7.6 4.6 5.9 0.8 8.4 3.4 6 0.6 7.6 4.6 340 6 332 165 1.7 0 1.8 1.6 02/11/2006 06:10:00 6.6 0.9 8.8 4.9 6.2 1.1 8.4 3 6.5 0.9 8.8 4.9 345 5 347 165 1.7 0 1.8 1.6 02/11/2006 06:20:00 6 0.8 8 4.2 4.5 1.2 8 2.3 6.2 0.7 8.4 4.9 346 0 347 165 1.7 0 1.8 1.6 02/11/2006 06:30:00 7 0.7 9.1 5.3 6.7 1.1 9.1 3.4 6.8 0.6 8.8 5.3 347 0 347 165 1.7 0 1.8 1.6 02/11/2006 06:40:00 6.6 0.8 9.1 4.6 6.4 1 9.1 3.4 6.2 0.9 8.8 4.6 346 0 347 165 1.6 0 1.6 1.6 02/11/2006 06:50:00 5.2 1.1 8.8 3 5.1 1.1 8.4 3 5.4 1 8.4 3.4 346 0 346 165 1.6 0 1.6 1.6 02/11/2006 07:00:00 5.8 0.8 7.6 3.4 5.7 0.9 7.6 3.4 5.9 0.7 7.6 4.2 346 0 346 165 1.6 0 1.6 1.6 02/11/2006 07:10:00 7.6 1.1 9.9 4.9 7.5 1.3 10.3 3.8 7.7 1.1 10.3 5.3 345 0 346 165 1.6 0 1.8 1.4 02/11/2006 07:20:00 7.6 1 9.9 5.3 7.6 1.1 11.1 4.9 7.7 1 10.7 5.3 344 1 343 165 1.7 0 1.8 1.6 02/11/2006 07:30:00 8 0.8 10.3 6.5 8.1 0.9 10.7 5.3 8 0.8 10.3 6.1 339 3 343 165 1.8 0 1.8 1.6 02/11/2006 07:40:00 8.1 0.8 10.3 6.5 8.2 0.8 10.7 6.5 8.2 0.8 10.7 6.5 336 4 339 165 1.9 0 2.1 1.8 02/11/2006 07:50:00 6.9 0.9 9.5 4.9 6.9 1 10.3 4.9 6.9 0.8 9.5 4.9 334 9 343 165 2 0 2.3 1.8 02/11/2006 08:00:00 6.3 1 8.8 4.6 6.2 1 9.5 3.4 6.4 1 8.8 4.6 339 9 342 165 1.9 0 2.1 1.6 02/11/2006 08:10:00 6.2 0.8 8.4 4.2 6.2 1 8.8 3.8 6.4 0.8 8.8 4.6 336 9 343 165 1.8 0 2.1 1.8 02/11/2006 08:20:00 7.9 1.1 10.3 5.7 8.1 1.2 10.7 5.7 8 1.1 10.3 5.7 338 6 343 165 2 0 2.3 1.8 02/11/2006 08:30:00 8.4 0.8 10.3 6.5 8.5 0.9 10.7 5.7 8.5 0.7 10.3 6.8 341 6 342 165 2.1 0 2.3 1.8 02/11/2006 08:40:00 8.1 0.7 9.9 6.5 8.3 0.8 10.3 6.5 8.2 0.7 9.9 6.5 342 5 345 165 2 0 2.3 1.8 02/11/2006 08:50:00 6.6 1 8.8 4.2 6.2 1.7 8.8 2.3 6.9 1 8.8 4.9 347 8 343 165 1.9 0 2.1 1.8 02/11/2006 09:00:00 5.8 0.8 8 3.8 5.5 1.2 8 2.6 5.9 0.7 8 4.2 343 10 335 165 1.9 0 1.8 1.8 02/11/2006 09:10:00 5.3 0.6 6.8 3.8 5.2 0.8 7.2 2.6 5.5 0.6 7.2 3.8 333 6 336 165 1.7 0 1.8 1.6 02/11/2006 09:20:00 6.5 0.7 8.4 3.8 6 1.2 8.8 3 6.6 0.7 8 4.9 346 8 343 165 1.9 0 2.3 1.8 02/11/2006 09:30:00 5.9 0.6 8 4.6 4.3 0.8 6.5 2.6 6.2 0.6 8.4 4.9 358 7 358 165 2.1 0 2.3 1.8 02/11/2006 09:40:00 5.8 0.6 7.6 4.6 4.9 1.2 7.6 2.6 6.1 0.6 7.6 4.6 351 7 355 165 2.1 0 2.3 1.8 02/11/2006 09:50:00 4.7 0.7 6.8 2.6 3.5 1.1 6.1 1.1 4.8 0.6 6.8 3 354 8 15 165 2.1 0 2.3 2.1 02/11/2006 10:00:00 3.9 0.6 5.3 2.3 3.8 0.9 5.3 1.5 4.3 0.7 5.7 2.6 20 10 13 165 2.3 0.1 2.6 2.1 02/11/2006 10:10:00 4.6 0.7 6.1 3 4.5 0.8 6.1 1.9 5.1 0.6 6.1 3.4 19 6 17 165 2.6 0 2.8 2.6 02/11/2006 10:20:00 4.7 0.4 5.7 3.8 4.8 0.4 5.7 3.8 5.1 0.4 6.1 4.2 28 5 18 165 2.5 0 2.6 2.6 02/11/2006 10:30:00 4.6 0.5 5.7 2.6 4.6 0.7 5.7 1.9 5.1 0.5 6.1 3.8 25 8 31 165 2.4 0 2.6 2.3 02/11/2006 10:40:00 4.8 0.4 5.7 3.4 4.8 0.5 6.1 3.8 5.1 0.5 6.1 4.2 30 6 39 165 2.3 0 2.6 2.3 02/11/2006 10:50:00 5.4 0.4 6.5 4.2 5.4 0.5 6.5 3.8 5.5 0.5 6.5 3.8 38 5 36 165 2.3 0 2.6 2.3 02/11/2006 11:00:00 4.9 0.5 6.1 3.8 4.9 0.5 6.1 3.4 5 0.5 6.5 3.4 40 5 44 165 2.1 0 2.3 2.1 02/11/2006 11:10:00 4.3 0.6 5.7 2.3 4.3 0.7 5.7 2.3 4.5 0.6 6.1 1.5 40 12 39 165 2 0 2.3 1.8 02/11/2006 11:20:00 4.5 1.2 8.4 1.5 4.6 1.2 8.8 1.9 4.4 1 8 2.6 61 19 83 165 2.1 0.1 2.6 1.8 02/11/2006 11:30:00 5.9 1.3 8.4 3 6.1 1.3 8.8 3 5.6 1.3 8.8 3.4 74 12 72 165 2.5 0.1 2.8 2.3 02/11/2006 11:40:00 5.4 0.8 7.6 3 5.6 0.8 8 3.8 5.4 0.8 8 3 79 10 68 165 2.7 0 2.8 2.8 02/11/2006 11:50:00 5.3 0.9 7.6 2.3 5.5 1 7.6 2.3 5.1 0.9 7.2 1.9 81 15 97 165 2.8 0 3 2.6 02/11/2006 12:00:00 5.5 1.1 8.4 3 5.7 1.2 8.4 3 5.5 1 8.4 3.4 84 13 84 165 2.9 0 3 2.8 02/11/2006 12:10:00 5.7 1.2 8.8 3 5.9 1.2 9.1 3.4 5.6 1.2 8.4 3 92 13 92 165 2.9 0 3 2.6 02/11/2006 12:20:00 4.7 1.6 8 0.7 4.9 1.6 8.4 0.7 4.6 1.5 7.6 1.1 84 16 84 165 2.5 0 2.6 2.3 02/11/2006 12:30:00 2.2 0.5 3.4 1.1 2 0.8 3.8 0.4 2.5 0.5 3.8 1.5 41 26 87 165 2 0.1 2.3 1.8 02/11/2006 12:40:00 1.7 0.5 2.6 0.4 0.8 0.4 1.9 0.4 2.1 0.4 3 1.1 3 8 349 165 1.8 0 1.8 1.6 02/11/2006 12:50:00 2 0.3 2.6 1.5 0.4 0 0.4 0.4 2.4 0.2 3 1.9 3 1 3 165 1.7 0 1.8 1.6 02/11/2006 13:00:00 1.7 0.5 2.6 0.4 0.4 0 0.4 0.4 2.2 0.5 3 0.4 7 1 6 165 1.7 0 1.8 1.6 02/11/2006 13:10:00 2.2 0.4 3 0.7 0.4 0 0.4 0.4 2.6 0.3 3.4 1.5 4 1 4 165 1.6 0 1.8 1.6 02/11/2006 13:20:00 2.7 1 5.3 0.7 0.8 1.1 5.7 0.4 2.7 0.8 5.3 1.1 43 26 74 165 1.8 0.1 2.1 1.6 02/11/2006 13:30:00 6.1 1 8.8 3.4 6.3 1.2 9.1 2.6 5.7 1 8.4 3.4 108 12 113 165 2.9 0.3 3.3 2.1 02/11/2006 13:40:00 5.2 1.1 7.2 2.3 5.7 1.2 7.6 2.3 5.1 1.1 7.2 2.3 94 12 102 165 3 0 3.3 3 02/11/2006 13:50:00 4 1 6.8 1.9 4.2 1 6.5 2.3 3.6 1 6.5 1.5 94 12 94 165 3 0.2 3.5 2.6 02/11/2006 14:00:00 1.4 0.9 4.2 0.4 1.3 1 4.2 0.4 1.5 0.8 3.4 0.4 43 86 98 165 2.7 0.1 3 2.6 02/11/2006 14:10:00 1.1 0.5 2.6 0.4 1.1 0.5 2.3 0.4 1.5 0.5 2.6 0.4 11 23 23 165 2.4 0 2.6 2.3 02/11/2006 14:20:00 1.3 0.5 3 0.4 1 0.6 3 0.4 1.6 0.4 2.6 0.7 349 9 339 165 2.4 0 2.6 2.3 02/11/2006 14:30:00 0.7 0.3 1.5 0.4 0.6 0.2 1.1 0.4 1 0.3 1.9 0.4 11 17 351 165 2.3 0 2.6 2.3 02/11/2006 14:40:00 0.4 0.2 1.1 0.4 0.5 0.2 1.1 0.4 0.7 0.4 1.5 0.4 21 17 37 165 2.4 0 2.6 2.3 02/11/2006 14:50:00 0.9 0.3 1.9 0.4 1 0.3 1.9 0.4 1.3 0.2 1.9 0.7 322 12 310 165 2.3 0 2.6 2.1 02/11/2006 15:00:00 0.7 0.3 1.5 0.4 0.7 0.4 1.9 0.4 0.8 0.4 1.5 0.4 0 38 344 165 2.1 0 2.3 2.1 02/11/2006 15:10:00 1.1 0.8 3.4 0.4 1.2 0.8 3.4 0.4 0.8 0.7 2.6 0.4 51 18 68 165 2.2 0 2.3 2.1 02/11/2006 15:20:00 2.5 1.3 4.9 0.4 2.7 1.2 5.7 0.4 2.2 1.3 4.9 0.4 91 27 103 165 2.6 0.3 3 2.3 02/11/2006 15:30:00 2.9 0.8 4.9 0.7 3.1 0.8 4.9 1.1 2.9 0.8 4.9 1.1 112 16 82 165 2.9 0.1 3 2.8 02/11/2006 15:40:00 1.9 0.5 3.4 0.7 2.1 0.5 3.4 1.1 2.1 0.5 3.4 0.7 97 10 99 165 3 0 3.3 3 02/11/2006 15:50:00 2.8 0.4 4.2 1.9 3 0.4 4.6 1.9 3 0.5 4.2 1.9 92 8 98 165 3.2 0 3.5 3 02/11/2006 16:00:00 2.9 0.6 4.6 1.5 3.1 0.6 4.6 1.5 2.8 0.7 4.6 1.1 85 9 98 165 3.1 0.1 3.5 2.8 02/11/2006 16:10:00 3.3 0.7 5.3 1.5 3.5 0.7 5.3 1.5 3 0.8 4.9 0.7 81 11 90 165 3 0.1 3.3 2.8 02/11/2006 16:20:00 3.8 0.6 5.3 1.9 4 0.6 5.7 2.3 3.5 0.8 5.7 1.1 91 11 73 165 3 0.2 3.5 2.6 02/11/2006 16:30:00 4.6 1 6.8 2.3 4.7 0.9 7.2 2.3 4.5 1 6.8 1.9 91 8 83 165 3.3 0 3.5 3.3 02/11/2006 16:40:00 4.8 0.9 7.2 2.3 5 0.9 7.2 3 4.7 0.9 6.8 2.3 99 9 95 165 3.3 0 3.5 3.3 02/11/2006 16:50:00 5.5 1.3 8.4 1.9 5.7 1.3 8.4 2.3 5.2 1.5 8.4 1.1 104 14 99 165 3.2 0 3.5 2.8 02/11/2006 17:00:00 5.7 1 8 3 5.8 1 8 3 5.4 1 8 2.3 107 9 116 165 3 0 3.3 2.8 02/11/2006 17:10:00 4.7 0.8 6.8 2.3 4.8 0.8 7.2 2.3 4.3 0.9 6.1 2.3 111 12 114 165 3 0 3.3 2.8 02/11/2006 17:20:00 5 0.5 6.8 3.8 5.2 0.5 6.8 3.8 4.9 0.5 6.5 3.8 115 6 115 165 3.1 0 3.3 3 02/11/2006 17:30:00 5.1 0.5 6.5 3.8 5.2 0.5 6.8 3.8 4.9 0.5 6.5 3.4 117 6 131 165 3.3 0 3.5 3.3 02/11/2006 17:40:00 5.6 0.9 8 3.8 5.8 0.9 8 4.2 5.6 0.9 8.4 3.4 113 8 122 165 3.3 0 3.5 3.3 02/11/2006 17:50:00 6.6 0.7 8.8 4.9 6.7 0.7 8.8 4.9 6.4 0.8 9.1 4.6 121 10 121 165 3.4 0 3.5 3.3 02/11/2006 18:00:00 6.9 0.9 9.1 4.9 7 0.9 9.5 4.9 6.6 0.9 9.5 4.6 118 8 111 165 3.4 0 3.5 3.3 02/11/2006 18:10:00 6.5 1 8.8 3.8 6.6 1 9.1 4.2 6.5 1 8.8 3.8 122 13 114 165 3.3 0 3.5 3.3 02/11/2006 18:20:00 5.7 0.7 7.6 3.8 5.7 0.7 7.2 3.8 5.7 0.8 8.4 3.8 125 9 136 165 3.3 0 3.5 3.3 02/11/2006 18:30:00 5.6 0.7 7.2 3.8 5.7 0.7 7.2 4.2 5.7 0.7 7.6 3.8 114 7 112 165 3.3 0 3.5 3.3 02/11/2006 18:40:00 6.4 0.7 8.8 4.9 6.5 0.8 8.8 4.6 6.2 0.8 8 4.2 118 10 126 165 3.3 0 3.5 3.3 02/11/2006 18:50:00 6.7 0.7 10.3 4.2 6.7 0.7 10.3 4.6 6.4 0.8 8.8 4.6 116 8 111 165 3.3 0 3.5 3.3 02/11/2006 19:00:00 4.8 0.8 7.2 2.3 4.8 0.8 6.8 2.3 4.6 0.8 6.8 2.6 110 11 129 165 3.2 0 3.3 3.3 02/11/2006 19:10:00 4.1 0.8 6.1 2.3 4.2 0.8 6.5 2.3 3.9 0.8 5.7 2.3 90 16 91 165 2.9 0.2 3.3 2.6 02/11/2006 19:20:00 4.1 0.6 5.7 2.3 4.1 0.7 5.7 2.3 4.1 0.6 5.7 2.6 117 9 95 165 3.2 0 3.3 3 02/11/2006 19:30:00 4.6 0.6 6.1 3 4.7 0.6 6.5 3 4.5 0.6 6.5 2.6 116 8 135 165 3.2 0 3.3 3.3 02/11/2006 19:40:00 4.7 0.6 6.5 2.3 4.8 0.6 6.8 2.6 4.6 0.7 6.1 2.6 113 7 110 165 3.2 0 3.3 3.3 02/11/2006 19:50:00 3.9 0.8 5.3 2.3 4 0.9 5.7 1.9 3.9 0.8 5.3 1.9 110 10 125 165 3.2 0 3.3 3 02/11/2006 20:00:00 4 0.8 6.8 1.9 4.1 0.8 6.5 2.3 4 0.7 6.1 2.6 111 11 94 165 3.2 0 3.3 3 02/11/2006 20:10:00 3.3 0.6 4.9 1.9 3.4 0.7 5.3 1.9 3.4 0.6 4.6 1.9 98 13 105 165 3.2 0 3.3 3 02/11/2006 20:20:00 3.3 0.6 4.6 1.9 3.4 0.6 5.3 1.9 3.3 0.6 4.6 1.5 89 11 86 165 3 0 3.3 2.8 02/11/2006 20:30:00 3.4 0.6 4.6 1.9 3.5 0.6 4.9 1.5 3.4 0.7 4.9 1.5 84 10 78 165 3.1 0 3.3 3 02/11/2006 20:40:00 3.1 0.7 4.9 1.9 3.3 0.7 5.3 1.9 3.1 0.7 4.6 1.1 98 13 73 165 3.1 0 3.3 3 02/11/2006 20:50:00 3.6 0.5 4.6 2.3 3.7 0.5 4.9 2.3 3.5 0.5 4.9 2.3 101 9 98 165 3.1 0 3.3 3 02/11/2006 21:00:00 4.1 0.8 6.1 2.3 4.1 0.8 5.7 2.6 4.1 0.9 6.1 2.3 103 9 105 165 3 0 3.3 3 02/11/2006 21:10:00 3.6 0.8 6.1 1.5 3.7 0.8 6.1 1.5 3.6 0.9 5.7 1.1 89 10 94 165 3 0 3.3 3 02/11/2006 21:20:00 2.9 0.5 4.2 1.9 3 0.5 4.2 1.9 2.9 0.4 4.2 1.9 91 15 88 165 3 0 3.3 2.8 02/11/2006 21:30:00 2.3 0.4 3 1.1 2.4 0.4 3 1.1 2.4 0.4 3 1.5 52 7 51 165 2.6 0.1 2.8 2.3 02/11/2006 21:40:00 2.9 0.4 4.2 1.9 3 0.4 4.6 1.9 3.1 0.3 3.8 2.3 47 6 58 165 2.4 0 2.6 2.3 02/11/2006 21:50:00 2.8 0.4 3.8 1.9 2.8 0.4 3.8 1.9 3 0.3 3.8 2.3 44 7 45 165 2.3 0 2.6 2.3 02/11/2006 22:00:00 2.4 0.4 3 1.5 2.4 0.4 3.4 1.5 2.6 0.4 3.4 1.9 45 5 50 165 2.4 0 2.6 2.3 02/11/2006 22:10:00 2.1 0.5 3 0.7 2.1 0.5 3 0.7 2.3 0.5 3.4 1.1 33 5 43 165 2.4 0 2.6 2.3 02/11/2006 22:20:00 1.2 0.5 2.3 0.4 1.1 0.5 2.3 0.4 1.7 0.5 3 0.4 341 27 323 165 2 0.1 2.3 1.8 02/11/2006 22:30:00 1.9 0.5 3.4 0.4 2 0.5 3.4 0.4 2.3 0.4 3.4 1.5 321 8 314 165 1.9 0 1.8 1.8 02/11/2006 22:40:00 2.5 0.8 4.6 0.4 2.6 0.8 4.9 0.4 2.5 0.6 4.6 0.7 311 11 291 165 1.9 0 2.1 1.8 02/11/2006 22:50:00 3.9 0.6 5.7 1.9 3.9 0.6 6.1 1.5 3.3 0.6 4.9 1.9 296 6 291 165 1.8 0 1.8 1.6 02/11/2006 23:00:00 5.2 0.4 6.5 4.2 5.2 0.5 6.5 4.2 4.3 0.6 6.1 3 301 7 300 165 1.6 0 1.8 1.6 02/11/2006 23:10:00 5 0.7 7.2 3.4 4.9 0.7 7.2 3.4 4.7 0.6 6.5 3.4 310 7 301 165 1.7 0 1.8 1.4 02/11/2006 23:20:00 5.2 0.8 6.8 3 5.1 0.8 7.2 3 4.8 0.8 7.6 3 309 11 298 165 1.7 0 1.8 1.6 02/11/2006 23:30:00 7.6 1.9 11.8 3.8 7.5 1.9 11.8 3.8 7.1 1.5 11.1 3.8 311 10 307 165 1.7 0 1.8 1.6 02/11/2006 23:40:00 9.4 1 12.6 7.6 9.3 1 12.6 7.2 8.5 1 10.3 5.3 302 1 302 165 1.7 0 1.8 1.6 02/11/2006 23:50:00 9.7 0.9 13 7.6 9.8 1 13.3 7.6 9.3 0.9 11.8 7.2 302 0 302 165 1.7 0 1.8 1.6 02/12/2006 00:00:00 9.9 1 13.7 7.6 9.9 1.1 13.7 7.6 9 1.1 12.2 6.5 302 0 302 165 1.7 0 1.8 1.6 02/12/2006 00:10:00 10.9 1.1 14.1 7.2 10.9 1.1 13.7 7.6 10 1.1 13 7.6 302 0 302 165 1.7 0 1.8 1.6 02/12/2006 00:20:00 14.1 1 16.4 11.1 14.2 1 16.1 11.1 13 1.4 16.4 8.8 302 0 302 165 1.7 0 1.8 1.6 02/12/2006 00:30:00 13 1.2 15.6 9.5 13 1.3 15.6 9.1 12.2 1.7 15.6 7.6 302 0 302 165 1.7 0 1.8 1.6 02/12/2006 00:40:00 12.8 1 14.9 9.9 12.8 1 14.9 9.5 11.3 1.2 14.1 8.4 302 0 302 165 1.7 0 1.8 1.6 02/12/2006 00:50:00 12.9 1 15.6 9.9 12.9 1 15.3 10.3 11.4 1.1 14.1 8.4 302 0 302 165 1.5 0.1 1.6 1.4 02/12/2006 01:00:00 13.5 1 15.6 10.7 13.5 1 15.6 10.7 12 1.2 14.9 8.4 302 0 302 165 1.4 0 1.6 1.4 02/12/2006 01:10:00 14.5 0.9 17.6 11.5 14.6 0.9 17.6 11.8 13.1 1.2 16.4 9.9 302 0 302 165 1.4 0 1.6 1.4 02/12/2006 01:20:00 14.8 1.1 17.6 11.5 14.8 1.1 17.6 11.1 12.8 1.2 16.1 9.9 302 0 302 165 1.4 0 1.6 1.4 02/12/2006 01:30:00 15 1.4 17.9 11.1 15 1.4 17.9 10.7 12.7 1.8 17.2 8.4 302 0 302 165 1.4 0 1.6 1.4 02/12/2006 01:40:00 14.5 1.2 17.9 11.1 14.5 1.2 18.3 11.1 11.6 1.7 15.6 7.6 302 0 302 165 1.4 0 1.6 1.4 02/12/2006 01:50:00 15.1 1.1 17.9 12.2 15.2 1.1 17.9 12.6 13.5 1.5 16.8 9.1 302 0 302 165 1.4 0 1.6 1.4 02/12/2006 02:00:00 16.2 1.3 20.6 13.7 16.2 1.4 20.6 13.3 13.6 1.8 17.9 9.1 302 0 302 165 1.3 0 1.4 1.1 02/12/2006 02:10:00 16.3 1.3 19.9 11.8 16.4 1.3 20.2 12.6 15.1 1.8 19.5 9.1 302 0 302 165 1.2 0 1.4 1.1 02/12/2006 02:20:00 17.4 1.7 21.8 13 17.4 1.7 21.8 13 16.2 2 19.9 9.1 302 0 302 165 1.2 0 1.4 0.9 02/12/2006 02:30:00 17.3 1.1 20.2 14.1 17.2 1.1 20.2 14.1 16.1 1.3 19.5 11.8 302 0 302 165 1.2 0 1.4 1.1 02/12/2006 02:40:00 17.4 1.4 19.9 13.7 17.3 1.4 20.2 13.3 16.2 1.5 19.5 12.2 302 0 302 165 1 0 1.4 0.9 02/12/2006 02:50:00 17.1 1.5 22.1 14.1 17 1.5 21.8 13.7 15.6 1.6 19.5 11.1 302 0 302 165 0.8 0 0.9 0.9 02/12/2006 03:00:00 17.3 1.3 20.2 13.7 17.3 1.3 20.2 13.7 16 1.7 20.6 11.8 303 0 302 165 0.8 0 0.9 0.7 02/12/2006 03:10:00 16.8 1.5 20.6 13.3 16.8 1.5 21 13.3 14.9 1.9 20.2 10.7 303 0 302 165 0.8 0 0.9 0.7 02/12/2006 03:20:00 18.4 2.2 23.7 13.7 18.4 2.2 23.7 13.7 15.5 1.9 21 10.7 303 0 302 165 0.8 0 1.1 0.7 02/12/2006 03:30:00 19.2 2.1 23.3 13.3 19.2 2.1 23.7 13.7 16.6 2.1 22.1 11.8 303 0 302 165 0.8 0 0.9 0.7 02/12/2006 03:40:00 19.2 1.7 24 14.9 19.2 1.7 24 14.9 16.4 2.3 22.6 11.1 303 0 302 165 0.7 0 0.9 0.7 02/12/2006 03:50:00 18.2 1.5 22.6 14.5 18.2 1.5 22.9 14.5 16.1 1.9 21.4 11.1 303 0 302 165 0.5 0 0.9 0.2 02/12/2006 04:00:00 20.5 2.3 25.2 14.5 20.5 2.4 25.6 14.1 16.9 1.8 21.4 12.2 303 0 302 165 0.4 0 0.7 0.2 02/12/2006 04:10:00 20.6 2.2 24.8 16.1 20.6 2.2 25.2 16.1 17.1 2 24 12.6 302 0 302 165 0.2 0 0.7 -0.1 02/12/2006 04:20:00 20.4 2.2 26 14.9 20.4 2.3 26 14.5 16.7 1.7 22.1 12.2 302 0 302 165 0 0 0.2 -0.1 02/12/2006 04:30:00 22.3 1.8 26.3 17.9 22.2 1.8 26.3 17.9 17.6 1.7 22.9 13.7 302 0 302 165 0.1 0 0.2 -0.1 02/12/2006 04:40:00 21.9 1.7 26.8 17.9 21.8 1.7 26.8 17.9 17 1.5 21.8 13 302 0 302 165 0.1 0 0.2 -0.1 02/12/2006 04:50:00 20.9 2.5 26.3 15.3 20.9 2.5 26 14.9 17.2 2.6 25.2 12.2 302 0 302 165 -0.1 0 0.2 -0.3 02/12/2006 05:00:00 21.4 2.4 26.3 15.6 21.4 2.5 26.8 14.9 17.9 2.5 23.3 10.7 302 0 302 165 -0.2 0 -0.1 -0.5 02/12/2006 05:10:00 23 2.2 30.9 17.2 23 2.2 30.6 17.2 19.2 2.4 27.9 11.8 302 0 302 165 -0.3 0.1 -0.1 -0.5 02/12/2006 05:20:00 22.7 2.4 30.2 17.9 22.6 2.5 30.6 17.2 19.5 2.3 28.7 15.3 302 0 302 165 -0.3 0 -0.1 -0.5 02/12/2006 05:30:00 21.9 2.6 27.5 15.6 21.9 2.6 27.5 15.3 18.6 2.5 25.6 13 302 0 302 165 -0.5 0.1 -0.3 -0.8 02/12/2006 05:40:00 22.9 2.2 28.7 16.8 22.9 2.3 28.7 17.6 18.4 2.2 25.6 13 302 0 302 165 -0.3 0 -0.1 -0.5 02/12/2006 05:50:00 22.5 2.3 27.1 16.8 22.4 2.4 27.1 16.4 18.4 2.7 26.3 12.2 302 0 302 165 -0.4 0 -0.3 -0.8 02/12/2006 06:00:00 22.1 2.3 27.1 16.1 22.1 2.3 26.8 16.1 17.7 2.7 26.8 12.2 302 0 302 165 -0.3 0 -0.3 -0.5 02/12/2006 06:10:00 21.6 2.2 27.5 15.6 21.6 2.3 27.1 15.3 17.3 2.4 24.8 11.8 302 0 302 165 -0.3 0 -0.3 -0.5 02/12/2006 06:20:00 23.2 1.8 27.1 17.9 23.2 1.9 27.1 17.6 18.8 2.5 25.2 11.1 302 0 302 165 -0.3 0 -0.3 -0.5 02/12/2006 06:30:00 23.9 2.4 29.1 17.2 23.8 2.5 29.1 17.2 18.9 2.4 26.8 12.6 301 0 302 165 -0.3 0 -0.3 -0.5 02/12/2006 06:40:00 23.1 2.5 29.1 16.1 23.1 2.6 28.7 16.1 18.7 2.6 26.3 12.6 301 0 301 165 -0.3 0 -0.3 -0.5 02/12/2006 06:50:00 21.2 2.6 27.1 14.5 21.1 2.6 27.5 14.5 17 2.5 26.8 10.3 301 0 301 165 -0.5 0 -0.3 -0.5 02/12/2006 07:00:00 19.7 2.5 26.3 13.7 19.7 2.5 27.1 13.7 16.5 2.7 23.3 10.7 301 0 301 165 -0.5 0 -0.3 -0.8 02/12/2006 07:10:00 18.9 2.3 24 13.3 18.9 2.3 24.4 13 16 2.8 23.3 10.3 301 0 301 165 -0.6 0 -0.5 -0.8 02/12/2006 07:20:00 19 2.5 26 13 19 2.5 26 12.6 16.2 2.9 25.6 9.5 301 0 301 165 -0.6 0 -0.5 -0.8 02/12/2006 07:30:00 17.4 2.7 23.7 9.9 17.4 2.7 23.3 10.3 14.5 2.7 23.7 8 300 0 300 165 -0.6 0 -0.5 -0.8 02/12/2006 07:40:00 17.3 2.8 22.6 10.7 17.3 2.8 22.9 10.3 15.1 3.2 24.4 8 300 0 300 165 -0.6 0 -0.5 -0.8 02/12/2006 07:50:00 16.3 2.7 24.4 9.9 16.2 2.7 24 9.5 13.9 2.7 23.7 8 300 0 300 165 -0.6 0 -0.5 -0.8 02/12/2006 08:00:00 14.1 2.6 20.2 7.6 14.2 2.6 20.2 7.6 12.8 2.7 20.6 7.6 299 0 300 165 -0.6 0 -0.5 -0.8 02/12/2006 08:10:00 13.9 2.8 20.2 7.2 14 2.8 19.9 7.2 12.2 2.7 19.1 4.9 299 0 299 165 -0.8 0.1 -0.5 -0.8 02/12/2006 08:20:00 14.2 2.7 20.2 7.6 14.3 2.7 20.2 8 12.7 2.9 20.2 6.5 299 0 298 165 -0.9 0 -0.8 -1.2 02/12/2006 08:30:00 12.8 2.1 18.3 8 12.8 2.1 18.3 8 11.2 2.4 19.5 6.8 298 0 298 165 -1.1 0 -0.8 -1.2 02/12/2006 08:40:00 12.5 2.6 20.2 6.8 12.6 2.7 21.4 6.8 10.9 2.9 19.5 4.6 298 0 298 165 -1.2 0 -1 -1.2 02/12/2006 08:50:00 13.5 2.9 19.9 6.5 13.5 2.9 19.1 7.6 11.7 2.8 18.7 5.7 298 0 298 165 -1.2 0 -1 -1.4 02/12/2006 09:00:00 11.5 2 16.4 6.8 11.7 1.8 16.1 7.2 10.4 2 16.1 6.1 297 0 297 165 -1.2 0 -1 -1.2 02/12/2006 09:10:00 11.6 2.4 17.6 6.5 11.6 2.4 17.9 6.1 10.4 2.5 17.9 5.3 297 0 297 165 -1.2 0 -1.2 -1.4 02/12/2006 09:20:00 10.8 1.7 14.9 6.5 11 1.7 14.9 6.8 10.1 2.2 16.4 5.3 297 0 297 165 -1.3 0 -1.2 -1.4 02/12/2006 09:30:00 11.9 1.8 16.8 7.2 12 1.8 17.6 7.6 10.5 2.1 15.6 5.7 292 10 286 165 -1.2 0 -1.2 -1.4 02/12/2006 09:40:00 12.2 2 16.8 6.8 12.2 1.8 16.8 6.5 10.5 2 15.6 6.1 289 9 279 165 -1.4 0 -1.2 -1.4 02/12/2006 09:50:00 12 2.4 19.9 6.8 12 2.4 19.5 7.2 10.3 2.2 16.8 5.7 288 9 285 165 -1.4 0 -1.2 -1.4 02/12/2006 10:00:00 14.4 2.2 20.2 9.1 14.5 2.3 21 9.1 12.9 2.8 20.6 6.8 286 9 282 165 -1.5 0 -1.4 -1.7 02/12/2006 10:10:00 14.8 2 20.6 9.1 14.8 1.9 20.2 8.8 12.9 2.2 19.9 7.6 293 10 292 165 -1.6 0 -1.4 -1.7 02/12/2006 10:20:00 15.1 2.6 21 8 15 2.6 21 8.4 12.6 2.2 18.7 6.8 295 9 293 165 -1.7 0 -1.4 -1.9 02/12/2006 10:30:00 13.2 2.2 17.9 8 13.4 2.1 17.9 7.6 11.9 2.3 17.6 6.8 288 12 290 165 -1.7 0 -1.4 -1.9 02/12/2006 10:40:00 13.2 2.3 19.9 8.4 13.3 2.3 20.2 8.8 12 2.4 19.1 6.5 286 9 285 165 -1.7 0 -1.4 -1.9 02/12/2006 10:50:00 13.6 2.4 19.9 6.1 13.7 2.4 19.9 5.3 11.9 2.4 19.1 5.3 290 10 287 165 -1.7 0 -1.4 -1.9 02/12/2006 11:00:00 12.1 2.2 18.3 6.8 12.2 2.2 17.9 7.2 10.6 2.1 17.9 6.1 291 11 303 165 -1.6 0 -1.4 -1.7 02/12/2006 11:10:00 13.9 2.8 20.2 6.5 14 2.7 19.9 6.8 12.2 2.6 18.3 6.1 290 11 293 165 -1.6 0 -1.4 -1.9 02/12/2006 11:20:00 12.7 2.5 18.7 6.1 12.8 2.4 17.9 6.1 11.7 2.6 17.6 4.2 284 9 277 165 -1.6 0 -1.4 -1.9 02/12/2006 11:30:00 11.4 2.6 16.4 6.1 11.6 2.5 17.2 6.1 10.5 2.5 17.6 5.3 284 12 290 165 -1.4 0 -1.2 -1.7 02/12/2006 11:40:00 12.2 1.9 17.2 7.2 12.4 1.9 17.9 7.6 11.7 2.3 17.6 6.5 282 9 279 165 -1.4 0 -1.4 -1.4 02/12/2006 11:50:00 13.6 2.7 21 7.2 13.6 2.7 21.4 8 11.5 2.3 17.9 6.8 291 10 288 165 -1.6 0 -1.4 -1.7 02/12/2006 12:00:00 13.2 2.6 18.7 7.6 13.2 2.5 19.1 7.6 11.3 2.6 19.5 5.7 296 11 284 165 -1.6 0 -1.4 -1.7 02/12/2006 12:10:00 12.4 2.2 17.2 8 12.4 2.2 17.9 7.6 10.7 2.1 16.8 6.1 293 12 309 165 -1.4 0 -1.2 -1.7 02/12/2006 12:20:00 13.4 2 18.3 7.2 13.6 1.9 18.3 8.8 12.8 2.1 18.7 7.2 282 9 321 165 -1.5 0 -1.4 -1.7 02/12/2006 12:30:00 14.4 2.3 21.8 9.5 14.4 2.4 21.8 9.1 12.7 2.7 21.4 6.8 290 11 282 165 -1.4 0 -1.2 -1.4 02/12/2006 12:40:00 13.9 2.1 18.7 8.8 13.9 2.2 19.1 8.4 12.1 2.6 19.9 7.6 290 9 292 165 -1.5 0 -1.2 -1.7 02/12/2006 12:50:00 15.8 2.7 23.3 9.5 15.8 2.6 22.9 9.9 13.6 2.5 21 8 294 11 301 165 -1.7 0 -1.4 -1.9 02/12/2006 13:00:00 15.1 2.2 20.2 9.5 15.2 2.3 19.9 9.5 13.1 2.6 19.1 7.2 291 10 322 165 -1.6 0 -1.4 -1.9 02/12/2006 13:10:00 13 2 18.3 8 13.1 2.1 19.1 8.8 11.6 2.1 17.9 6.5 289 12 292 165 -1.6 0 -1.4 -1.7 02/12/2006 13:20:00 14 2 21 9.1 14.1 2 21 9.5 12.5 2.5 19.5 7.2 289 11 289 165 -1.7 0 -1.4 -1.9 02/12/2006 13:30:00 11.5 1.9 15.6 7.2 12.1 1.9 16.4 7.6 11.6 2.1 16.4 6.1 278 9 276 165 -1.8 0.1 -1.7 -1.9 02/12/2006 13:40:00 12.4 2.5 17.6 5.7 12.7 2.2 18.3 7.6 11.9 2.5 18.3 6.1 281 11 280 165 -1.7 0 -1.4 -1.9 02/12/2006 13:50:00 15.4 1.5 18.7 11.1 15.5 1.5 18.7 11.5 14.2 2.1 18.7 7.6 286 8 282 165 -1.6 0 -1.4 -1.9 02/12/2006 14:00:00 15.8 1.9 19.9 10.7 15.8 1.9 20.2 10.3 14.6 2.6 20.6 8.8 286 9 282 165 -1.6 0 -1.4 -1.7 02/12/2006 14:10:00 15.1 1.7 18.7 8.8 15.2 1.7 19.1 9.5 14.1 2.1 19.5 7.6 284 8 280 165 -1.6 0 -1.4 -1.9 02/12/2006 14:20:00 14.1 1.7 19.1 9.5 14.3 1.7 18.7 9.5 13.5 2.2 18.7 8.4 284 6 276 165 -1.5 0 -1.2 -1.7 02/12/2006 14:30:00 13 1.3 16.4 9.5 13.2 1.3 16.8 9.1 12.6 1.5 16.1 7.6 281 5 272 165 -1.4 0 -1.2 -1.4 02/12/2006 14:40:00 11.1 1.5 14.5 6.5 11.3 1.4 14.9 7.2 10.7 1.6 15.6 6.5 282 6 285 165 -1.4 0 -1.2 -1.4 02/12/2006 14:50:00 9.9 1.7 13.7 4.2 10.1 1.6 13.3 4.9 9.4 1.7 13.7 4.2 283 8 290 165 -1.3 0.1 -0.8 -1.4 02/12/2006 15:00:00 9.6 1.1 13.7 6.5 9.8 1.1 13.3 6.8 9.3 1.2 12.6 6.1 282 7 287 165 -0.9 0 -0.8 -1.2 02/12/2006 15:10:00 9.5 1.1 12.6 6.5 9.6 1.1 12.6 6.8 8.9 1.3 12.6 4.9 283 6 282 165 -0.9 0 -0.8 -1 02/12/2006 15:20:00 6.8 1.7 11.5 3 7.4 1.5 11.5 4.6 6.9 1.5 11.8 3.8 277 9 284 165 -0.8 0 -0.5 -1 02/12/2006 15:30:00 6.2 1.6 9.9 2.6 6.7 1.3 9.9 4.2 6.3 1 8.8 3.8 278 12 296 165 -0.8 0 -0.5 -0.8 02/12/2006 15:40:00 4.4 1.1 7.6 1.9 5.6 1.2 8.8 3 5.4 1.1 8 3 260 8 280 165 -0.2 0.1 0.2 -0.8 02/12/2006 15:50:00 2.9 1 5.3 0.7 3.4 0.9 6.1 1.5 3.2 0.7 5.7 1.9 248 19 266 165 0.7 0.4 1.4 -0.1 02/12/2006 16:00:00 3.1 1 5.7 0.4 3.4 1 6.1 0.4 3 0.9 5.3 1.1 281 15 265 165 1.2 0 1.4 0.9 02/12/2006 16:10:00 6.1 2.3 10.7 1.5 6.2 2.2 10.7 1.5 5.4 1.9 10.7 1.5 298 15 289 165 0.9 0.4 1.4 0.2 02/12/2006 16:20:00 7.6 1.5 10.7 3 7.6 1.5 10.7 2.6 6.8 1.6 10.7 3.4 287 9 292 165 0.1 0 0.2 -0.1 02/12/2006 16:30:00 5.4 1.7 9.1 1.9 5.5 1.6 9.1 2.3 5.1 1.7 9.9 1.9 282 11 295 165 -0.1 0 0.2 -0.3 02/12/2006 16:40:00 5.7 1.5 9.5 2.6 6 1.4 9.9 2.6 5.5 1.5 9.1 2.6 281 13 277 165 -0.2 0.1 -0.1 -0.5 02/12/2006 16:50:00 5.6 1.3 9.9 3 6.4 1.3 10.7 3.8 6 1.1 9.1 3 259 15 281 165 -0.5 0 -0.3 -0.8 02/12/2006 17:00:00 4.6 0.8 7.6 2.6 5 0.8 7.6 3.4 4.7 0.8 6.8 3 246 10 247 165 -0.5 0 -0.3 -0.8 02/12/2006 17:10:00 4.8 1 7.2 2.6 5 0.9 7.6 3 4.7 0.9 6.8 2.6 238 10 229 165 -0.6 0 -0.5 -0.8 02/12/2006 17:20:00 4 0.8 6.5 1.9 4.2 0.7 6.5 2.3 4.1 0.8 6.1 2.6 233 12 242 165 -0.9 0.3 -0.5 -1.4 02/12/2006 17:30:00 3.3 0.8 5.3 1.5 3.5 0.7 5.3 1.5 3.3 0.6 4.6 1.9 240 9 239 165 -1.5 0 -1.2 -1.7 02/12/2006 17:40:00 4.2 0.9 6.5 2.3 4.3 1 6.5 2.3 3.9 0.9 6.5 2.3 216 11 218 165 -1.6 0 -1.4 -1.9 02/12/2006 17:50:00 3.5 0.7 5.3 1.9 3.6 0.7 5.3 2.3 3.4 0.7 5.3 1.9 218 12 210 165 -1.7 0 -1.4 -1.9 02/12/2006 18:00:00 3.2 0.7 4.6 1.1 3.3 0.7 4.6 1.5 3.2 0.7 4.6 1.5 205 10 204 165 -1.6 0 -1.4 -1.7 02/12/2006 18:10:00 3.3 0.9 4.9 1.5 3.4 0.8 5.3 1.9 3.4 0.9 5.7 1.5 192 10 197 165 -1.6 0 -1.4 -1.7 02/12/2006 18:20:00 4.4 0.6 5.7 3.4 4.3 0.6 5.3 3.4 4.5 0.6 5.7 3 177 3 180 165 -1.7 0 -1.4 -1.9 02/12/2006 18:30:00 3.8 0.5 4.6 2.3 3.8 0.5 4.9 2.6 4.1 0.5 4.9 3 187 10 180 165 -1.6 0 -1.4 -1.9 02/12/2006 18:40:00 3.9 0.4 4.9 2.6 4 0.4 4.9 3 4 0.5 4.9 3 199 9 208 165 -1.6 0.1 -1.2 -1.9 02/12/2006 18:50:00 4.6 0.6 6.1 3 4.8 0.6 6.5 3.4 4.8 0.6 7.2 3.8 207 9 191 165 -1.4 0 -1.2 -1.7 02/12/2006 19:00:00 4.7 0.7 6.5 3.4 5 0.7 6.8 3.4 5 0.8 7.2 3.8 217 6 211 165 -1.6 0 -1.4 -1.7 02/12/2006 19:10:00 4.7 0.6 6.5 3.8 4.9 0.6 6.5 3.8 4.9 0.5 6.1 3.4 218 6 218 165 -1.6 0 -1.2 -1.7 02/12/2006 19:20:00 5.7 0.8 7.2 3.8 6 0.8 7.6 4.2 6 0.8 7.6 3.8 221 7 218 165 -1.4 0 -1.2 -1.7 02/12/2006 19:30:00 6.9 0.8 8.4 4.6 7.2 0.8 8.8 4.9 7 0.8 8.8 5.3 209 5 207 165 -1 0.1 -0.8 -1.4 02/12/2006 19:40:00 6 1.1 8.4 3.8 6.2 1.1 8.8 3.8 5.9 1.1 8.4 3.8 208 5 205 165 -0.9 0 -0.8 -1.2 02/12/2006 19:50:00 4.9 0.9 7.2 2.6 4.9 0.9 7.2 2.6 4.8 0.8 6.8 3 188 9 193 165 -1.2 0 -1 -1.4 02/12/2006 20:00:00 6 0.7 7.6 4.2 6.1 0.6 7.6 4.6 6 0.8 7.6 3.4 201 5 199 165 -1 0.1 -0.8 -1.4 02/12/2006 20:10:00 6.5 1.1 9.1 4.2 6.7 1.1 9.5 4.2 6.4 1.1 9.1 3.8 206 7 208 165 -0.6 0 -0.5 -1 02/12/2006 20:20:00 7.5 0.9 9.5 5.7 7.8 1 9.9 5.7 7.4 1 10.3 5.3 221 5 217 165 -0.3 0.1 -0.1 -0.8 02/12/2006 20:30:00 6.1 1.2 8.4 3.4 6.3 1.2 8.4 3.8 6.1 1.1 8.4 3.4 211 8 205 165 -0.2 0 -0.1 -0.3 02/12/2006 20:40:00 4.3 0.5 5.3 2.3 4.5 0.5 5.3 2.6 4.5 0.5 5.7 3 200 8 201 165 -0.3 0 -0.1 -0.5 02/12/2006 20:50:00 4.1 0.6 5.7 3 4.1 0.6 5.7 3 4.1 0.6 5.7 2.6 195 9 192 165 -0.2 0 -0.1 -0.3 02/12/2006 21:00:00 4.5 0.6 6.5 3 4.7 0.6 6.1 3.4 4.4 0.5 6.1 3.4 209 5 211 165 0.1 0 0.2 -0.1 02/12/2006 21:10:00 5.5 1.1 8.8 2.6 5.5 1.1 8.4 3 5.7 1 9.1 3.4 187 15 193 165 0.3 0 0.7 0.2 02/12/2006 21:20:00 5.3 0.6 6.8 3.8 5.2 0.6 6.5 3.4 5.4 0.6 6.5 3.8 180 10 190 165 -0.1 0 0.2 -0.1 02/12/2006 21:30:00 7.4 1.1 11.1 4.9 7.5 1 11.1 5.3 7.2 1.1 10.3 4.6 202 6 206 165 0.4 0.3 0.9 -0.1 02/12/2006 21:40:00 6.8 0.8 8.8 4.6 6.9 0.8 8.8 4.9 6.9 0.8 8.8 4.6 196 5 198 165 0.7 0 0.9 0.7 02/12/2006 21:50:00 8.2 0.7 10.3 6.5 8.2 0.7 10.3 6.5 8.2 0.8 10.7 6.5 192 6 194 165 0.8 0.1 1.1 0.7 02/12/2006 22:00:00 7.9 0.6 9.5 5.3 8 0.6 9.5 5.7 7.9 0.8 10.3 5.7 193 6 196 165 0.9 0 1.1 0.9 02/12/2006 22:10:00 7.8 0.8 9.5 6.5 7.6 0.8 9.5 5.7 7.9 0.8 10.3 6.1 181 7 190 165 0.9 0 1.1 0.9 02/12/2006 22:20:00 7.3 0.4 8 6.5 7 0.3 7.6 6.1 7.5 0.4 8.4 6.5 175 5 174 165 0.8 0 0.9 0.7 02/12/2006 22:30:00 7.4 0.7 9.5 6.1 7.2 0.7 9.1 5.7 7.7 0.8 9.5 6.1 184 4 190 165 0.7 0.1 0.9 0.7 02/12/2006 22:40:00 7.2 0.8 9.1 5.7 7.1 0.8 9.1 5.3 7.4 0.8 9.9 5.7 183 9 197 165 0.8 0 1.1 0.7 02/12/2006 22:50:00 7.5 0.6 8.8 6.1 7.2 0.6 8.4 5.7 7.7 0.7 9.1 6.1 171 6 165 165 0.5 0 0.9 0.2 02/12/2006 23:00:00 7.1 0.8 9.1 5.3 6.8 0.7 8.8 5.3 7.2 0.7 8.8 4.9 170 4 181 165 0.4 0 0.7 0.2 02/12/2006 23:10:00 5.5 0.6 6.8 3.8 5.3 0.5 6.5 3.8 5.6 0.6 7.2 3.8 173 5 171 165 0.5 0 0.7 0.2 02/12/2006 23:20:00 4.4 0.5 5.3 3 4.4 0.4 5.3 3.4 4.6 0.5 5.7 3.4 181 5 175 165 0.6 0 0.9 0.2 02/12/2006 23:30:00 3.3 0.4 4.2 2.3 3.4 0.4 4.2 2.6 3.6 0.4 4.6 3 190 4 185 165 0.7 0 0.9 0.2 02/12/2006 23:40:00 3.9 0.4 4.9 3 3.9 0.3 4.9 3.4 4.2 0.3 5.3 3.8 182 5 179 165 0.7 0 0.9 0.7 02/12/2006 23:50:00 5 0.4 6.1 4.2 5 0.3 5.7 4.2 5.3 0.4 6.1 4.2 181 3 182 165 0.8 0 0.9 0.7 02/13/2006 00:00:00 2.9 0.8 4.9 1.5 3.2 0.8 4.9 1.5 3.2 0.8 5.3 1.9 203 10 183 165 0.8 0 0.9 0.7 02/13/2006 00:10:00 0.8 0.6 2.3 0.4 1 0.7 2.6 0.4 1.4 0.6 3 0.4 280 53 214 165 0.7 0 0.9 0.7 02/13/2006 00:20:00 0.5 0.4 1.9 0.4 0.9 0.5 2.3 0.4 1.2 0.5 2.3 0.4 299 41 234 165 0.5 0 0.9 0.2 02/13/2006 00:30:00 2.1 0.6 3.4 1.1 2.5 0.5 3.8 1.5 2.5 0.6 3.8 1.5 220 8 211 165 1.1 0.1 1.4 0.7 02/13/2006 00:40:00 3.2 0.2 3.8 2.6 3.5 0.2 3.8 3 3.5 0.2 4.2 3 210 4 204 165 1.4 0 1.4 1.4 02/13/2006 00:50:00 3.8 0.4 4.6 3 4 0.4 4.9 3.4 4.2 0.4 4.9 3 200 5 196 165 1.4 0 1.6 1.4 02/13/2006 01:00:00 3.9 0.3 4.6 3 4 0.3 4.6 3 4 0.4 4.9 3 196 4 195 165 1.4 0.1 1.6 1.1 02/13/2006 01:10:00 3.7 0.4 4.6 2.3 3.9 0.4 4.6 2.6 3.8 0.4 4.6 2.6 222 6 224 165 1.4 0.2 1.8 1.1 02/13/2006 01:20:00 3.5 0.5 4.2 2.6 3.8 0.5 4.9 2.6 3.8 0.4 4.6 3 226 4 220 165 1.7 0 1.8 1.6 02/13/2006 01:30:00 3.1 0.3 3.8 2.3 3.4 0.3 4.2 2.6 3.5 0.4 4.2 2.6 222 3 230 165 1.7 0 1.8 1.6 02/13/2006 01:40:00 1.4 0.6 2.6 0.4 1.9 0.4 3 0.7 2 0.5 3 1.1 252 27 224 165 1.5 0 1.6 1.4 02/13/2006 01:50:00 0.9 0.5 2.3 0.4 1.4 0.5 2.6 0.4 1.2 0.6 2.3 0.4 280 13 297 165 1.8 0 1.8 1.6 02/13/2006 02:00:00 0.6 0.3 1.9 0.4 1 0.5 2.3 0.4 1.2 0.5 2.3 0.4 270 10 249 165 1.8 0 1.8 1.6 02/13/2006 02:10:00 2 1 4.6 0.4 2.3 0.9 4.6 0.7 2.5 0.7 4.6 1.1 260 23 281 165 1.8 0 1.8 1.6 02/13/2006 02:20:00 3.4 0.7 4.6 0.7 3.7 0.6 4.6 1.5 3.3 0.8 4.6 1.1 288 9 287 165 1.7 0 1.8 1.6 02/13/2006 02:30:00 3.3 0.4 4.2 2.3 3.5 0.4 4.2 2.6 3 0.6 4.6 1.9 291 7 281 165 1.7 0 1.8 1.6 02/13/2006 02:40:00 3.9 0.5 5.3 2.6 4.1 0.5 5.3 3 3.3 0.6 4.9 2.3 292 6 301 165 1.7 0 1.8 1.6 02/13/2006 02:50:00 4.4 0.4 5.3 3 4.6 0.4 5.3 3.4 3.6 0.5 4.9 2.3 295 5 296 165 2 0.1 2.3 1.6 02/13/2006 03:00:00 5.2 0.4 6.1 4.2 5.2 0.4 6.1 4.2 4.1 0.5 5.7 2.6 304 4 302 165 2.4 0 2.6 2.3 02/13/2006 03:10:00 4.8 0.4 6.5 3.8 4.9 0.4 6.5 3.8 3.9 0.5 5.3 2.6 306 5 310 165 2.1 0.1 2.3 1.8 02/13/2006 03:20:00 4.1 0.8 6.1 2.3 4.2 0.8 6.1 2.6 3.5 0.7 5.7 1.9 303 8 323 165 2.5 0.1 2.8 1.8 02/13/2006 03:30:00 3.3 0.7 4.9 1.9 3.5 0.6 4.9 2.3 2.8 0.6 4.9 1.5 302 8 297 165 2.6 0 2.8 2.6 02/13/2006 03:40:00 2.8 0.6 4.2 1.5 3 0.5 4.2 1.5 2.6 0.5 4.6 1.5 304 10 287 165 2.5 0.1 2.8 2.3 02/13/2006 03:50:00 2.2 0.5 3.4 0.7 2.5 0.5 3.8 1.1 2.5 0.5 3.4 1.1 289 9 296 165 2.4 0 2.6 2.3 02/13/2006 04:00:00 3.1 0.4 3.8 1.9 3.3 0.3 4.2 2.3 2.7 0.4 3.8 1.9 296 4 294 165 2.3 0 2.6 2.1 02/13/2006 04:10:00 3.2 0.4 3.8 2.3 3.4 0.4 4.2 2.6 2.8 0.4 3.8 1.9 294 2 290 165 2.1 0 2.3 1.8 02/13/2006 04:20:00 3.4 0.4 4.2 2.6 3.6 0.4 4.6 2.6 3.1 0.4 4.2 1.9 292 5 293 165 2.1 0 2.3 1.8 02/13/2006 04:30:00 4.4 0.6 6.1 3.4 4.5 0.5 6.1 3.8 3.7 0.6 5.7 2.3 293 4 295 165 2 0 2.3 1.8 02/13/2006 04:40:00 5.9 0.6 8 4.2 6 0.6 7.6 4.6 5 0.6 6.8 3.4 293 4 295 165 2 0 2.3 1.8 02/13/2006 04:50:00 6.1 0.5 7.2 4.9 6.2 0.5 7.2 4.9 4.5 0.5 6.8 3.4 299 3 298 165 2 0.1 2.3 1.8 02/13/2006 05:00:00 5 0.4 6.1 4.2 5 0.4 6.1 4.2 3.8 0.5 4.9 2.6 300 4 296 165 1.7 0 1.8 1.6 02/13/2006 05:10:00 5 0.3 5.7 4.2 5.1 0.3 6.1 4.2 3.9 0.5 4.9 3 302 4 302 165 1.7 0 1.8 1.4 02/13/2006 05:20:00 4.8 0.4 5.7 3.4 4.9 0.4 5.7 3.4 4 0.5 5.3 2.6 304 5 301 165 1.7 0 1.8 1.6 02/13/2006 05:30:00 4.4 0.3 5.3 3.8 4.6 0.3 5.7 3.8 4.1 0.5 5.3 3 309 3 310 165 1.7 0 1.8 1.6 02/13/2006 05:40:00 4.9 0.6 6.1 3.4 5 0.6 6.5 3.8 4.8 0.6 6.1 3.4 314 8 311 165 1.8 0 1.8 1.6 02/13/2006 05:50:00 3.8 0.5 4.9 1.9 3.9 0.5 4.9 2.3 3.7 0.6 4.9 1.9 311 8 324 165 1.9 0.1 2.3 1.6 02/13/2006 06:00:00 3.9 0.4 4.9 2.6 4 0.4 4.9 3 3.1 0.4 4.2 2.3 300 6 292 165 2.1 0 2.3 2.1 02/13/2006 06:10:00 3.8 0.4 4.6 2.3 3.9 0.4 4.9 2.6 3.5 0.4 4.6 2.6 286 6 291 165 2.3 0 2.6 2.1 02/13/2006 06:20:00 3.5 0.5 4.6 1.9 4.1 0.3 4.6 3.4 4.1 0.3 4.9 3.4 265 8 272 165 2.4 0 2.6 2.3 02/13/2006 06:30:00 2.5 0.5 3.4 1.1 3.1 0.5 4.2 1.9 3.3 0.4 4.2 2.3 249 7 245 165 2.6 0 2.8 2.3 02/13/2006 06:40:00 2.5 0.3 3.4 1.9 2.7 0.3 3.4 2.3 3.1 0.2 3.8 2.3 224 13 242 165 2.4 0.1 2.8 2.1 02/13/2006 06:50:00 1.5 0.4 2.3 0.7 1.8 0.3 2.6 1.1 2.2 0.3 3 1.5 196 2 197 165 2.1 0 2.3 2.1 02/13/2006 07:00:00 1.1 0.4 1.9 0.4 1.4 0.3 2.3 0.7 1.7 0.3 2.3 1.1 206 3 195 165 2 0 2.3 1.8 02/13/2006 07:10:00 0.9 0.4 1.5 0.4 1.1 0.4 1.5 0.4 1.3 0.4 1.9 0.4 173 5 190 165 1.9 0 2.1 1.8 02/13/2006 07:20:00 1.2 0.5 2.6 0.4 1.5 0.4 2.6 0.7 1.6 0.4 3 0.7 178 13 202 165 1.8 0 1.8 1.6 02/13/2006 07:30:00 2.6 0.3 3 1.9 2.7 0.3 3.4 2.3 2.8 0.4 3.4 1.9 201 3 202 165 1.9 0 1.8 1.8 02/13/2006 07:40:00 2.2 0.5 3 1.1 2.3 0.4 3.4 1.5 2.4 0.4 3.4 1.5 180 9 201 165 1.8 0.1 2.1 1.4 02/13/2006 07:50:00 2.9 0.5 3.8 1.9 2.9 0.4 3.8 1.9 3 0.4 4.2 2.3 176 7 165 165 1.6 0 1.8 1.4 02/13/2006 08:00:00 3.1 0.3 3.8 2.3 3.1 0.3 3.8 2.6 3.1 0.4 3.8 2.3 181 4 179 165 1.7 0.1 1.8 1.6 02/13/2006 08:10:00 2.7 0.7 3.4 0.7 2.7 0.6 3.4 1.1 2.8 0.6 3.8 1.5 180 7 189 165 2.1 0 2.3 1.8 02/13/2006 08:20:00 1.3 0.3 1.9 0.4 1.5 0.3 2.3 0.7 1.5 0.3 2.3 1.1 168 4 165 165 1.9 0 2.1 1.8 02/13/2006 08:30:00 1.9 0.9 3.4 0.7 2.1 0.8 3.4 0.7 2.1 0.8 3.8 0.7 177 3 176 165 2.1 0.2 2.6 1.8 02/13/2006 08:40:00 2.2 0.9 3.8 0.4 2.3 0.8 3.4 0.7 2.6 0.7 3.8 1.1 151 7 164 165 1.5 0.5 2.6 0.9 02/13/2006 08:50:00 1.5 0.6 2.6 0.4 1.7 0.5 2.6 0.4 1.8 0.6 2.6 0.4 171 9 179 165 1.7 0.6 2.8 0.9 02/13/2006 09:00:00 0.9 0.5 1.9 0.4 1.3 0.4 1.9 0.4 1.4 0.4 2.3 0.7 162 5 165 165 3 0.1 3.3 2.6 02/13/2006 09:10:00 2.2 0.6 3 1.1 2.4 0.5 3 1.5 2.5 0.6 3.4 1.1 148 6 137 165 2.6 0.3 3.3 2.3 02/13/2006 09:20:00 3 0.4 3.8 2.3 3.1 0.4 3.8 2.3 3.1 0.3 3.8 2.3 150 5 143 165 1.8 0 2.3 1.6 02/13/2006 09:30:00 2.8 0.4 3.8 1.9 2.8 0.4 3.8 2.3 2.9 0.3 3.8 2.3 155 4 159 165 1.9 0.1 2.1 1.6 02/13/2006 09:40:00 2.5 0.2 3 1.9 2.6 0.2 3.4 1.9 2.7 0.2 3.4 1.9 151 8 150 165 2.3 0.1 2.6 2.1 02/13/2006 09:50:00 2.7 0.4 4.2 1.5 2.9 0.4 4.2 1.9 3 0.4 4.2 1.9 143 10 122 165 2.4 0 2.6 2.3 02/13/2006 10:00:00 1.9 0.3 2.6 1.1 2.2 0.3 3 1.5 2 0.3 2.6 1.1 157 4 148 165 2.5 0 2.6 2.6 02/13/2006 10:10:00 2 0.4 3 1.1 2.3 0.4 3 1.5 2.2 0.5 3.4 1.1 149 11 162 165 2.7 0 2.8 2.6 02/13/2006 10:20:00 2.3 0.5 3.8 1.1 2.4 0.4 3.8 1.5 2.3 0.4 3.4 1.5 161 9 177 165 2.6 0 2.8 2.6 02/13/2006 10:30:00 2.7 0.3 3.8 1.9 2.9 0.3 3.8 2.3 2.9 0.3 3.8 2.3 144 13 176 165 2.4 0 2.8 2.3 02/13/2006 10:40:00 2.6 0.3 3.4 1.9 2.8 0.3 3.4 2.3 2.8 0.3 3.8 1.9 122 6 125 165 2.3 0 2.6 2.3 02/13/2006 10:50:00 2.1 0.4 3 1.1 2.2 0.4 3 1.5 2.3 0.4 3 1.5 140 9 137 165 2.3 0 2.6 2.3 02/13/2006 11:00:00 3 0.6 4.2 1.5 3 0.6 3.8 1.5 3 0.5 4.2 1.9 146 8 153 165 2.4 0 2.6 2.3 02/13/2006 11:10:00 2.6 0.3 3.4 1.5 2.6 0.3 3.4 1.9 2.6 0.4 3.4 1.9 150 6 147 165 2.5 0 2.8 2.3 02/13/2006 11:20:00 2.4 0.3 3 1.5 2.5 0.2 3 1.9 2.6 0.3 3 1.9 145 4 150 165 2.3 0 2.6 2.3 02/13/2006 11:30:00 2.6 0.5 3.8 1.5 2.6 0.5 4.2 1.5 2.4 0.4 3.8 1.5 155 13 244 165 2.3 0 2.6 2.1 02/13/2006 11:40:00 2.6 0.5 3.8 1.1 2.6 0.5 3.8 1.5 2.6 0.4 3.8 1.5 176 9 183 165 3.2 0.3 3.5 2.6 02/13/2006 11:50:00 3.2 0.4 4.6 1.9 3.1 0.4 4.6 1.9 3.2 0.4 4.2 2.3 154 12 145 165 2.9 0.4 3.5 2.3 02/13/2006 12:00:00 3.2 0.3 3.8 2.6 3.2 0.3 4.2 2.3 3.1 0.4 3.8 2.3 139 10 118 165 2.2 0 2.6 1.8 02/13/2006 12:10:00 4.3 0.9 5.7 2.6 4.2 0.8 5.3 2.6 4.1 0.8 5.7 2.6 163 9 177 165 2.1 0 2.6 1.8 02/13/2006 12:20:00 4.3 0.5 5.3 3 4.1 0.5 5.3 2.6 4.2 0.5 5.3 3 180 6 186 165 2.5 0 2.8 2.3 02/13/2006 12:30:00 4.9 0.9 8 2.6 4.9 0.9 8 2.6 4.6 0.9 7.2 2.3 195 12 204 165 2.9 0.1 3.3 2.6 02/13/2006 12:40:00 2 1 4.6 0.4 2.3 0.9 4.6 0.4 2.2 1 4.6 0.4 230 23 223 165 3.2 0 3.5 3 02/13/2006 12:50:00 1.7 1 4.2 0.4 1.9 1 4.2 0.4 1.9 1 4.2 0.4 217 28 205 165 3.5 0 3.5 3.3 02/13/2006 13:00:00 2.2 1.2 4.9 0.4 2.2 1.2 4.9 0.4 2.2 1 4.6 0.4 171 22 191 165 3.5 0 3.5 3.3 02/13/2006 13:10:00 2.8 0.7 4.6 0.7 2.9 0.7 4.9 1.1 2.8 0.6 4.6 1.1 182 18 201 165 3.6 0 3.8 3.5 02/13/2006 13:20:00 2.4 0.6 3.8 0.7 2.5 0.6 3.8 1.1 2.7 0.5 3.8 1.1 158 10 161 165 3.6 0 3.8 3.5 02/13/2006 13:30:00 3.5 0.8 4.9 1.9 3.4 0.7 4.6 1.9 3.5 0.7 4.9 1.9 160 13 166 165 3.3 0 3.5 3.3 02/13/2006 13:40:00 3.9 0.6 4.9 2.6 3.7 0.5 4.6 2.3 3.8 0.7 4.9 2.3 170 12 165 165 3.5 0.1 3.8 3.3 02/13/2006 13:50:00 3.4 0.5 4.6 2.3 3.3 0.4 4.6 2.3 3.1 0.5 4.2 2.3 186 9 201 165 3.8 0 4 3.5 02/13/2006 14:00:00 3.4 0.5 4.6 1.5 3.4 0.5 4.6 1.9 3.2 0.6 4.6 1.9 187 13 174 165 4 0 4.3 3.8 02/13/2006 14:10:00 4.5 1 6.8 2.6 4.4 0.9 6.5 2.6 4.5 1 6.8 2.6 177 10 176 165 4 0 4.3 3.8 02/13/2006 14:20:00 5.5 0.6 6.8 3.8 5.3 0.6 6.8 3.8 5.3 0.7 6.8 3.4 187 11 201 165 3.9 0 4.3 3.8 02/13/2006 14:30:00 5.9 0.7 8 3.8 5.8 0.7 7.6 3.8 5.8 0.7 8.4 4.2 192 8 195 165 3.9 0 4.3 3.5 02/13/2006 14:40:00 7.5 1.2 9.9 4.9 7.4 1.2 9.5 4.9 7.5 1.2 9.9 4.9 193 6 188 165 4 0 4.3 3.8 02/13/2006 14:50:00 6.6 1.4 9.5 3.8 6.5 1.4 9.1 3.4 6.7 1.4 9.9 4.6 186 8 187 165 3.9 0 4.3 3.8 02/13/2006 15:00:00 5.6 1 8.4 2.6 5.6 1 8.4 2.6 5.5 1 8.4 3 187 14 202 165 3.8 0 4 3.5 02/13/2006 15:10:00 6.2 1.1 9.1 2.6 6.2 1.1 8.8 3 6.1 1 8.4 3.4 203 8 205 165 4 0 4.3 3.8 02/13/2006 15:20:00 6.3 0.8 7.6 3.8 6.4 0.8 8 3.8 6.4 0.8 8 4.2 201 5 197 165 3.8 0 4 3.5 02/13/2006 15:30:00 6.1 0.6 7.6 4.2 6.1 0.7 7.6 4.2 6.3 0.7 8.4 4.6 195 4 195 165 3.7 0 3.8 3.5 02/13/2006 15:40:00 5.9 0.9 7.6 3.4 5.8 0.9 7.6 3.8 6 0.9 7.6 3.8 183 6 182 165 3.6 0 3.8 3.5 02/13/2006 15:50:00 6.2 0.7 7.6 4.2 6 0.6 7.6 4.2 6.3 0.6 8 4.6 175 6 176 165 3.6 0 3.8 3.5 02/13/2006 16:00:00 5.2 0.6 6.5 3.8 5 0.5 6.5 3.4 5.3 0.5 6.8 4.2 178 5 182 165 3.5 0 3.5 3.5 02/13/2006 16:10:00 5.1 0.5 6.5 3.4 5 0.5 6.1 3.8 5.3 0.4 6.5 4.2 185 5 182 165 3.6 0 3.8 3.5 02/13/2006 16:20:00 5.5 0.6 7.2 4.2 5.3 0.6 6.8 4.2 5.6 0.6 7.2 4.2 174 9 165 165 3.4 0 3.5 3.3 02/13/2006 16:30:00 5.7 0.7 7.2 3.8 5.5 0.6 7.2 3.8 5.7 0.6 6.8 4.2 175 6 164 165 3.3 0 3.5 3.3 02/13/2006 16:40:00 6.1 0.6 7.6 4.2 5.9 0.6 7.2 4.6 6.1 0.5 7.6 4.6 176 5 182 165 3.5 0 3.5 3.3 02/13/2006 16:50:00 5.3 0.6 6.5 3.8 5.2 0.5 6.5 3.8 5.6 0.5 6.8 4.6 157 6 154 165 3 0.1 3.5 2.8 02/13/2006 17:00:00 5.7 0.5 6.8 4.6 5.4 0.4 6.5 4.6 5.8 0.5 6.8 4.6 166 9 165 165 3 0 3.3 2.8 02/13/2006 17:10:00 5.7 0.5 6.8 4.6 5.5 0.4 6.8 4.6 5.8 0.5 7.2 4.6 169 4 167 165 3.2 0 3.5 3 02/13/2006 17:20:00 5.3 0.5 6.1 4.2 5.2 0.4 6.1 3.8 5.3 0.5 6.5 3.8 167 6 167 165 3.2 0 3.5 3 02/13/2006 17:30:00 4.5 0.6 6.1 3.4 4.4 0.5 5.7 3.4 4.6 0.5 6.1 3.4 159 12 164 165 3.2 0 3.5 3 02/13/2006 17:40:00 4.3 0.7 5.7 2.6 4.3 0.6 5.3 2.6 4.4 0.5 5.7 3 152 13 169 165 3.2 0.1 3.5 3 02/13/2006 17:50:00 4.5 0.5 6.1 3 4.5 0.5 6.1 2.6 4.7 0.4 6.1 3 149 9 127 165 3 0 3.3 2.8 02/13/2006 18:00:00 3.6 0.6 5.3 2.3 3.6 0.6 4.9 2.3 4.1 0.6 6.1 2.3 149 13 159 165 3.2 0 3.5 3 02/13/2006 18:10:00 3.4 0.6 4.9 1.9 3.5 0.6 4.9 2.3 3.6 0.5 4.9 2.3 153 8 156 165 3.2 0 3.5 3 02/13/2006 18:20:00 2.6 0.5 3.4 1.5 2.8 0.4 3.8 1.5 3.1 0.5 4.2 1.9 134 10 141 165 3.3 0 3.5 3.3 02/13/2006 18:30:00 2.7 0.4 3.8 1.5 2.9 0.4 3.8 1.9 2.8 0.4 4.2 1.5 187 14 165 165 3.9 0.2 4.3 3.3 02/13/2006 18:40:00 2.9 0.5 4.2 1.5 3.2 0.5 4.6 1.9 3 0.5 4.2 1.5 224 9 215 165 4.4 0 4.8 4.3 02/13/2006 18:50:00 3.4 0.6 4.6 1.1 3.6 0.6 4.9 1.9 3.4 0.7 4.9 1.1 227 11 225 165 4.5 0 4.8 4.3 02/13/2006 19:00:00 4.3 0.8 6.1 1.9 4.6 0.7 6.1 2.3 4.1 0.9 6.1 1.9 208 8 215 165 4.3 0.1 4.5 4.3 02/13/2006 19:10:00 5.2 0.5 6.5 3.4 5.3 0.5 6.5 3.8 5.4 0.5 6.5 3.8 195 5 196 165 4.1 0 4.3 4 02/13/2006 19:20:00 5.4 1.1 8.8 3.8 5.4 1 8.8 3.8 5.5 1 8 4.2 186 8 180 165 4.1 0 4.3 3.8 02/13/2006 19:30:00 6.7 0.9 9.5 4.6 6.7 0.9 9.9 4.9 6.7 0.9 9.1 4.6 191 8 194 165 3.9 0 4 3.8 02/13/2006 19:40:00 6.2 0.7 8.4 4.6 6.2 0.7 8 4.2 6.1 0.6 8 4.6 188 6 192 165 3.8 0 4 3.8 02/13/2006 19:50:00 7.6 1 10.3 5.3 7.6 1 10.3 5.3 7.6 1 11.1 5.7 195 7 197 165 4.2 0.1 4.5 3.8 02/13/2006 20:00:00 8.2 0.5 9.9 6.5 8.3 0.5 10.3 6.8 8.3 0.6 9.9 6.8 198 4 198 165 4.2 0 4.5 4.3 02/13/2006 20:10:00 8.4 0.7 9.9 5.7 8.4 0.7 10.3 5.7 8.4 0.8 10.3 6.1 199 5 210 165 4.3 0 4.5 4.3 02/13/2006 20:20:00 7.5 0.9 9.9 5.3 7.3 0.9 9.9 4.9 7.4 1 9.9 4.9 182 11 178 165 4.1 0.1 4.5 3.8 02/13/2006 20:30:00 10.1 0.8 12.2 8 10.2 0.8 12.6 8.4 10.3 1 13 7.2 198 5 203 165 4.1 0 4.3 3.8 02/13/2006 20:40:00 10.5 0.7 11.8 8 10.5 0.7 11.8 8 10.6 0.9 12.6 8 196 5 204 165 4 0 4.3 3.8 02/13/2006 20:50:00 9.3 0.8 11.1 7.6 9.2 0.8 11.1 7.2 9.3 0.8 11.5 6.8 191 5 197 165 3.7 0 3.8 3.5 02/13/2006 21:00:00 6.3 1.2 9.1 3 6.2 1.2 9.1 3.4 6.4 1.1 8.8 3.4 184 10 189 165 3.6 0 3.8 3.5 02/13/2006 21:10:00 8.5 1.3 11.1 5.3 8.3 1.2 11.1 5.3 8.5 1.3 11.8 4.9 183 7 173 165 3.5 0 3.5 3.3 02/13/2006 21:20:00 12.6 1.4 15.3 9.5 12.5 1.3 14.9 9.1 12.9 1.5 15.6 9.5 186 4 188 165 3.5 0 3.8 3.3 02/13/2006 21:30:00 11.8 0.9 13.7 9.9 11.6 0.9 13.3 9.9 12.1 1 14.1 9.9 185 3 187 165 3.6 0 3.8 3.5 02/13/2006 21:40:00 9.6 0.7 11.8 7.6 9.4 0.6 11.1 7.6 9.7 0.7 11.8 7.6 185 5 187 165 3.4 0 3.5 3.3 02/13/2006 21:50:00 11.2 1.1 13.3 7.2 11.1 1.1 13.3 7.2 11.5 1.1 13.7 8 193 5 190 165 3.6 0 3.8 3.5 02/13/2006 22:00:00 10 1 12.2 6.8 9.9 0.9 11.5 7.2 10.1 1.1 12.2 6.8 187 10 179 165 3.5 0.1 3.8 3.3 02/13/2006 22:10:00 10.3 1.2 12.6 6.5 9.9 1.1 12.2 6.1 10.5 1 13 8 164 9 148 165 2.9 0 3.3 2.8 02/13/2006 22:20:00 10.5 1.1 12.6 8 10.2 1.1 12.6 8 10.6 1.2 13 8 159 4 152 165 2.7 0 2.8 2.6 02/13/2006 22:30:00 9.1 0.7 10.7 7.6 8.9 0.6 10.7 7.6 9.2 0.7 11.1 7.6 167 8 165 165 2.6 0 2.8 2.6 02/13/2006 22:40:00 9.1 0.7 10.7 7.2 8.9 0.7 10.7 7.2 8.9 0.7 10.7 7.2 165 11 164 165 2.5 0 2.8 2.3 02/13/2006 22:50:00 9.8 0.8 11.5 6.8 9.6 0.7 11.1 6.8 9.8 0.9 11.5 6.8 164 10 164 165 2.4 0 2.6 2.3 02/13/2006 23:00:00 10.2 0.7 11.5 7.6 9.8 0.6 11.1 7.6 10.1 0.8 11.8 7.6 166 5 173 165 2.4 0 2.6 2.3 02/13/2006 23:10:00 10.1 0.7 12.2 8 9.8 0.7 11.5 7.6 10.1 0.7 12.6 8 165 17 164 165 2.4 0 2.6 2.3 02/13/2006 23:20:00 9.7 0.8 11.5 7.2 9.4 0.8 11.1 7.2 9.9 0.8 12.2 7.6 169 12 173 165 2.4 0 2.6 2.3 02/13/2006 23:30:00 7.7 0.9 9.9 5.3 7.4 0.8 9.5 5.7 7.6 0.8 9.1 5.3 171 11 178 165 2.5 0 2.8 2.3 02/13/2006 23:40:00 7.5 0.8 10.3 5.7 7.2 0.7 9.9 5.7 7.5 0.8 9.9 6.1 170 9 179 165 2.8 0 2.8 2.6 02/13/2006 23:50:00 7.3 1 10.3 5.3 7.1 1 9.9 5.3 7.3 0.9 9.5 5.3 171 8 197 165 3 0 3.3 2.8 02/14/2006 00:00:00 7.7 0.4 9.1 6.1 7.4 0.4 8.4 6.1 7.8 0.4 8.8 6.5 167 6 164 165 2.9 0 3 2.8 02/14/2006 00:10:00 7.3 0.5 8.8 6.5 6.9 0.5 8.4 6.1 7.2 0.5 8.4 6.1 168 6 172 165 2.7 0 2.8 2.6 02/14/2006 00:20:00 7.9 0.6 9.1 6.1 7.5 0.5 8.8 6.1 8 0.6 9.5 6.5 170 9 173 165 2.9 0 3 2.8 02/14/2006 00:30:00 8.7 1.3 12.2 6.5 8.4 1.3 12.2 6.1 8.8 1.3 12.2 6.5 177 9 191 165 3 0.2 3.5 2.6 02/14/2006 00:40:00 8.4 0.8 11.5 6.8 8.1 0.8 11.5 6.5 8.5 0.9 11.5 6.5 167 9 164 165 3 0.2 3.5 2.8 02/14/2006 00:50:00 8.3 0.6 9.9 6.5 8 0.6 9.5 6.5 8.5 0.6 9.9 6.8 160 6 158 165 3 0.1 3.5 2.8 02/14/2006 01:00:00 9.2 1.2 12.6 6.8 8.9 1.2 12.2 6.5 9.5 1.2 13 6.5 161 13 158 165 3 0 3.3 2.8 02/14/2006 01:10:00 8.5 2 12.6 3.4 8.3 1.9 12.2 3.8 8.7 1.9 12.6 4.2 168 19 175 165 3.5 0.1 3.8 3.3 02/14/2006 01:20:00 5.9 1.4 8.8 1.9 5.8 1.3 8.4 1.9 6.1 1.4 8.8 1.5 162 20 167 165 3.5 0.1 3.8 3.3 02/14/2006 01:30:00 6.4 2.4 12.2 1.5 6.3 2.3 11.8 1.5 6.7 2.2 12.6 2.6 152 36 176 165 3.8 0 4 3.5 02/14/2006 01:40:00 7.9 1.2 11.1 4.9 7.8 1.2 10.7 5.3 8.1 1.2 11.1 5.3 166 17 165 165 3.6 0.2 4 3.3 02/14/2006 01:50:00 9.5 1.3 12.6 5.3 9.2 1.2 12.6 4.9 9.6 1.3 12.6 4.9 171 11 172 165 3.4 0 3.5 3.3 02/14/2006 02:00:00 11.1 1.7 14.9 7.2 10.7 1.7 14.5 6.8 11.1 1.7 15.3 7.6 165 10 156 165 3.1 0.1 3.5 2.8 02/14/2006 02:10:00 11.4 1 13.7 8.8 11.1 0.9 13.3 8.4 11.5 0.9 13.3 9.1 161 13 165 165 3 0 3.3 2.8 02/14/2006 02:20:00 12.5 0.8 14.9 10.7 12.2 0.8 14.1 9.9 12.6 0.8 14.5 10.3 162 10 172 165 2.8 0 3.3 2.8 02/14/2006 02:30:00 12.7 1.1 15.3 10.3 12.3 1.1 14.9 9.9 12.9 1.2 15.6 9.9 164 18 164 165 2.7 0 2.8 2.6 02/14/2006 02:40:00 12.8 0.9 14.9 10.7 12.5 0.8 14.5 9.9 13.1 0.9 15.3 10.3 160 11 162 165 2.6 0.1 2.8 2.6 02/14/2006 02:50:00 13.2 0.9 14.9 10.7 12.8 0.8 14.5 10.7 13.4 0.9 15.3 10.7 159 10 162 165 2.4 0 2.6 2.3 02/14/2006 03:00:00 13.5 1.1 15.6 10.7 13.1 1 15.3 10.3 13.7 1.1 16.1 10.3 162 10 164 165 2.4 0 2.8 2.3 02/14/2006 03:10:00 14.7 0.6 16.1 13 14.3 0.6 15.6 11.8 14.9 0.7 16.4 13 165 12 165 165 2.4 0 2.8 2.3 02/14/2006 03:20:00 14 0.7 15.6 11.8 13.6 0.7 15.3 11.8 14 0.8 16.1 11.5 165 17 164 165 2.4 0 2.6 2.3 02/14/2006 03:30:00 14.6 0.8 16.1 11.5 14.2 0.7 15.6 11.5 14.7 0.8 16.4 12.2 165 13 162 165 2.4 0 2.6 2.3 02/14/2006 03:40:00 14 1.1 16.1 10.7 13.6 1.1 15.6 10.3 14.1 1.1 16.4 11.1 161 10 164 165 2.4 0 2.6 2.3 02/14/2006 03:50:00 13.1 1.1 15.6 9.9 12.8 1 15.3 9.1 13.4 1 16.1 10.7 157 6 162 165 2.4 0 2.6 2.3 02/14/2006 04:00:00 10.8 0.9 13.7 8.4 10.6 0.9 13.3 8.4 11 0.9 13.3 8.4 157 7 159 165 2.3 0 2.6 2.3 02/14/2006 04:10:00 10.4 0.9 12.6 7.6 10.1 0.8 12.2 7.6 10.5 0.8 12.2 7.6 156 6 164 165 2.3 0 2.6 2.3 02/14/2006 04:20:00 10.2 0.7 12.2 8.4 10 0.7 12.2 8.4 10.4 0.7 12.2 7.6 157 7 156 165 2.2 0 2.3 2.1 02/14/2006 04:30:00 10.4 0.9 12.2 8 10.1 0.9 11.8 8 10.6 0.9 12.6 8.4 159 9 162 165 2.1 0 2.3 2.1 02/14/2006 04:40:00 10.7 1 13 8.4 10.3 1 12.6 8 10.6 1.2 13.3 8 164 6 164 165 2.1 0 2.3 2.1 02/14/2006 04:50:00 11.1 0.8 13 8.8 10.8 0.7 12.6 8.4 11.3 0.8 13 8.8 163 6 165 165 2.1 0 2.3 2.1 02/14/2006 05:00:00 10.2 0.8 12.2 7.6 9.9 0.7 11.8 8 10.2 0.8 12.6 8 160 8 164 165 2.1 0 2.3 1.8 02/14/2006 05:10:00 9.5 0.7 11.5 7.2 9.3 0.7 11.1 7.2 9.6 0.8 11.5 7.6 162 13 163 165 2.2 0 2.3 2.1 02/14/2006 05:20:00 9.9 1 12.6 7.6 9.7 0.9 12.2 7.2 10 0.9 12.6 7.2 162 8 162 165 2.1 0 2.6 1.8 02/14/2006 05:30:00 10.7 0.9 12.2 7.2 10.4 0.8 12.2 7.2 10.7 1 13 6.8 164 13 167 165 2.4 0 2.6 2.3 02/14/2006 05:40:00 10.7 1.2 13 7.2 10.4 1.1 12.6 6.8 10.8 1.3 13 6.8 166 12 165 165 2.5 0 2.8 2.3 02/14/2006 05:50:00 9.9 0.9 11.5 7.6 9.6 0.8 11.5 7.6 9.8 1 11.8 7.6 166 11 170 165 2.3 0 2.6 2.3 02/14/2006 06:00:00 11 0.6 12.2 8.4 10.7 0.6 11.8 8.4 11 0.7 12.6 8.4 167 13 161 165 2.3 0 2.6 2.3 02/14/2006 06:10:00 9.8 0.7 11.1 7.2 9.7 0.7 11.1 6.8 9.6 0.8 11.5 7.6 166 10 165 165 2.3 0 2.6 2.1 02/14/2006 06:20:00 9.2 0.7 10.7 7.2 9.2 0.7 10.7 7.2 8.8 0.8 10.3 6.1 166 11 172 165 2.3 0 2.6 2.3 02/14/2006 06:30:00 9.6 0.6 11.1 8 9.5 0.6 10.7 7.6 9.6 0.8 11.5 7.6 167 6 169 165 2.4 0 2.6 2.3 02/14/2006 06:40:00 9 0.6 11.1 7.2 8.7 0.6 10.3 7.2 9 0.6 10.7 7.2 173 10 178 165 2.4 0 2.8 2.3 02/14/2006 06:50:00 9.5 0.6 11.1 7.6 9.3 0.6 11.1 7.6 9.8 0.6 11.1 8 178 5 187 165 2.8 0 2.8 2.6 02/14/2006 07:00:00 9.1 0.6 10.3 6.8 8.8 0.5 9.9 6.8 9.3 0.5 10.3 8 172 8 176 165 2.6 0.1 2.8 2.3 02/14/2006 07:10:00 9.7 0.7 11.5 8 9.4 0.7 11.1 8 9.9 0.7 11.5 8 178 6 174 165 2.9 0.1 3.3 2.6 02/14/2006 07:20:00 9.2 0.7 10.7 7.2 8.9 0.6 10.3 7.2 9.3 0.6 11.1 7.6 175 7 168 165 2.9 0 3.3 2.8 02/14/2006 07:30:00 9.4 0.6 10.7 7.6 9.1 0.5 10.3 7.6 9.7 0.6 11.1 8 168 6 165 165 2.7 0 2.8 2.6 02/14/2006 07:40:00 9.7 0.7 11.8 8 9.5 0.7 11.5 7.6 9.8 0.8 12.2 7.6 166 8 167 165 2.4 0 2.6 2.3 02/14/2006 07:50:00 10.8 0.5 11.8 9.5 10.5 0.5 11.8 9.1 10.9 0.5 12.2 9.5 166 11 161 165 2.4 0 2.6 2.3 02/14/2006 08:00:00 11.4 0.9 13 9.5 11 0.8 12.6 9.1 11.6 0.9 13.7 9.5 164 14 164 165 2.5 0 2.6 2.3 02/14/2006 08:10:00 13.2 0.6 14.5 11.5 12.8 0.6 14.1 11.1 13.4 0.7 14.9 11.1 167 13 164 165 2.4 0 2.6 2.3 02/14/2006 08:20:00 13.5 0.7 14.9 11.5 13.1 0.6 14.5 11.5 13.8 0.8 15.6 11.1 166 12 189 165 2.4 0 2.6 2.3 02/14/2006 08:30:00 13 0.7 14.5 10.3 12.6 0.7 14.1 10.3 13.2 0.8 14.9 11.1 166 12 167 165 2.4 0 2.6 2.3 02/14/2006 08:40:00 13.1 0.7 14.5 11.1 12.7 0.7 14.1 10.7 13.3 0.7 14.9 11.5 164 13 165 165 2.3 0 2.6 2.3 02/14/2006 08:50:00 13.4 0.6 14.5 11.1 12.9 0.6 14.1 11.1 13.5 0.7 14.9 11.5 166 5 163 165 2.3 0 2.6 2.3 02/14/2006 09:00:00 13.4 0.5 14.5 11.5 13 0.5 14.1 11.1 13.5 0.6 14.9 11.5 166 8 166 165 2.3 0 2.6 2.3 02/14/2006 09:10:00 12.7 0.7 14.1 10.7 12.3 0.7 13.7 10.3 13 0.8 14.5 10.7 167 17 169 165 2.4 0.1 2.8 2.1 02/14/2006 09:20:00 11.6 0.6 13.3 10.3 11.1 0.5 12.6 9.5 11.8 0.7 13.7 9.5 165 14 166 165 2.7 0 2.8 2.6 02/14/2006 09:30:00 10.5 0.6 12.2 9.1 10.1 0.6 11.8 9.1 10.8 0.6 12.6 9.5 168 5 163 165 2.9 0.1 3 2.6 02/14/2006 09:40:00 9.7 0.5 11.1 8 9.3 0.5 10.3 7.6 10 0.6 11.5 7.6 167 13 162 165 3 0 3.3 2.8 02/14/2006 09:50:00 8.4 0.6 10.3 7.2 8.1 0.6 9.9 6.8 8.7 0.6 11.1 6.8 165 11 161 165 3.2 0.1 3.5 2.8 02/14/2006 10:00:00 7.3 0.7 8.4 4.9 7 0.6 8 4.9 7.4 0.7 8.8 4.9 168 15 162 165 3.2 0.2 3.8 2.8 02/14/2006 10:10:00 6.9 0.5 8 5.3 6.6 0.5 8 5.7 7.1 0.5 8.8 5.7 174 6 175 165 3.6 0 3.8 3.3 02/14/2006 10:20:00 5.7 0.5 6.5 4.6 5.4 0.5 6.5 4.2 5.9 0.5 6.8 4.9 163 8 171 165 3 0.1 3.3 2.8 02/14/2006 10:30:00 6.7 0.6 7.6 5.3 6.4 0.5 7.6 4.9 6.9 0.6 8.4 5.3 168 7 166 165 3.5 0 3.8 3.3 02/14/2006 10:40:00 6.7 0.4 8 6.1 6.4 0.4 7.6 5.3 6.9 0.4 8 6.1 175 9 175 165 4 0 4.3 3.5 02/14/2006 10:50:00 6.3 0.4 7.2 5.3 6 0.4 7.2 4.9 6.5 0.4 7.6 5.3 171 6 176 165 4 0 4.3 3.8 02/14/2006 11:00:00 7 0.7 8.8 5.7 6.7 0.7 8.4 5.3 7.2 0.6 9.1 5.7 166 7 165 165 4.1 0 4.3 4 02/14/2006 11:10:00 7.9 0.5 9.1 6.5 7.7 0.5 8.8 6.1 8.2 0.6 9.5 6.5 163 12 163 165 4.1 0 4.3 3.8 02/14/2006 11:20:00 7.6 1 9.9 4.6 7.5 1 9.5 4.6 7.9 0.9 9.5 5.3 160 15 166 165 4.1 0.1 4.5 3.8 02/14/2006 11:30:00 7.9 0.7 9.5 6.1 7.6 0.6 8.8 5.7 8.1 0.8 9.9 5.7 162 9 167 165 4.3 0.1 4.8 4.3 02/14/2006 11:40:00 6.8 0.9 9.1 4.2 6.6 0.8 8.4 4.2 7 0.9 9.1 4.9 161 8 164 165 4.4 0.1 4.8 4.3 02/14/2006 11:50:00 7.3 0.5 8.4 5.7 7 0.5 8 5.3 7.5 0.5 8.8 6.1 163 6 163 165 4.3 0.1 4.8 4 02/14/2006 12:00:00 7.5 0.5 9.1 6.5 7.2 0.5 9.1 5.7 7.7 0.5 9.1 5.7 162 10 146 165 4.1 0.1 4.5 4 02/14/2006 12:10:00 8 0.7 9.9 6.5 7.8 0.6 9.5 6.5 8.4 0.7 10.3 6.8 157 6 165 165 4.5 0 4.8 4.3 02/14/2006 12:20:00 7.6 0.4 8.8 6.5 7.4 0.4 8.8 6.5 7.8 0.4 9.1 6.5 152 4 157 165 4.7 0 5 4.5 02/14/2006 12:30:00 7.5 0.6 9.1 5.7 7.4 0.6 9.1 5.7 7.6 0.6 9.5 6.1 154 4 164 165 4.7 0.2 5 3.8 02/14/2006 12:40:00 7.7 0.7 9.5 5.7 7.6 0.7 9.5 5.7 7.9 0.7 9.9 5.7 153 10 156 165 4.5 0.3 5 3.5 02/14/2006 12:50:00 9.1 0.6 10.7 7.6 8.9 0.6 10.7 7.2 9.3 0.7 12.2 7.2 158 6 156 165 4.6 0.1 4.8 4 02/14/2006 13:00:00 9.1 0.5 10.7 8 8.9 0.4 10.7 8 9.4 0.5 10.7 8 159 4 157 165 4.4 0 4.5 4.3 02/14/2006 13:10:00 9.1 0.4 10.3 8 8.8 0.4 9.9 7.6 9.3 0.4 10.7 8 160 3 162 165 4.2 0.1 4.5 3.5 02/14/2006 13:20:00 9 0.4 9.9 7.6 8.7 0.4 9.5 7.6 9.2 0.5 10.3 8 158 3 161 165 4.3 0 4.5 3.5 02/14/2006 13:30:00 9 0.3 9.9 8 8.7 0.3 9.5 7.6 9.2 0.4 10.3 8 159 5 160 165 3.8 0.3 4.3 3.3 02/14/2006 13:40:00 8.9 0.3 9.5 8 8.7 0.3 9.5 8 9 0.4 9.9 8 155 2 154 165 3.4 0 4 3.3 02/14/2006 13:50:00 9 0.3 9.9 8 8.9 0.3 9.9 7.6 9.2 0.4 10.3 8 151 3 151 165 3.3 0 3.5 3.3 02/14/2006 14:00:00 9.6 0.4 10.7 8.4 9.5 0.4 10.7 8 9.7 0.4 11.1 8.4 149 3 147 165 3.2 0 3.5 3.3 02/14/2006 14:10:00 10.9 0.6 12.2 9.5 10.8 0.6 11.8 9.5 11.1 0.6 12.2 9.9 151 3 148 165 3.2 0.1 3.3 3 02/14/2006 14:20:00 11.2 0.5 12.2 9.9 11 0.4 12.2 9.5 11.1 0.6 12.2 8.8 150 2 148 165 3 0 3.3 2.8 02/14/2006 14:30:00 11.6 0.3 13 10.3 11.4 0.3 12.6 10.3 11.6 0.5 12.6 9.9 151 2 151 165 2.9 0 3 2.8 02/14/2006 14:40:00 11.8 0.5 13 10.3 11.6 0.5 13 10.3 11.9 0.6 13 10.3 152 2 150 165 2.9 0 3 2.8 02/14/2006 14:50:00 12.2 0.3 13 11.1 12 0.3 12.6 11.1 12.3 0.4 13.3 11.1 152 2 152 165 2.9 0 3 2.8 02/14/2006 15:00:00 12.4 0.4 13.3 11.5 12.1 0.4 13 11.1 12.4 0.5 13.3 11.1 153 2 155 165 2.9 0 3 2.8 02/14/2006 15:10:00 12 0.4 13 11.1 11.7 0.4 12.6 10.7 12.1 0.5 13.3 10.3 156 2 155 165 2.9 0 3 2.8 02/14/2006 15:20:00 12.5 0.3 13.3 11.5 12.3 0.3 13 10.7 12.7 0.4 13.7 11.5 155 2 152 165 2.9 0 3 2.8 02/14/2006 15:30:00 11.8 0.6 13 10.3 11.5 0.6 12.6 9.9 12.1 0.6 13.3 9.9 157 3 160 165 2.9 0 3 2.8 02/14/2006 15:40:00 10.5 0.8 12.6 8.8 10.2 0.8 12.2 8.4 10.7 0.9 13 8.8 163 13 163 165 2.9 0 3.3 2.8 02/14/2006 15:50:00 9.7 0.6 11.1 8.4 9.4 0.5 10.7 8.4 9.9 0.7 11.1 8 163 17 163 165 3.1 0 3.3 3 02/14/2006 16:00:00 9.3 0.5 10.7 8 9.1 0.5 10.3 8 9.6 0.5 11.1 8.4 157 4 150 165 3.3 0.1 3.5 3 02/14/2006 16:10:00 11.1 0.6 12.6 9.1 10.9 0.6 12.2 8.8 11.2 0.7 12.6 9.1 151 4 158 165 2.7 0.2 3.5 2.6 02/14/2006 16:20:00 10.9 0.5 12.2 9.1 10.7 0.4 11.8 9.1 11 0.5 12.2 9.5 153 2 162 165 2.4 0 2.6 2.3 02/14/2006 16:30:00 10.5 0.4 11.5 9.5 10.3 0.4 11.5 9.1 10.6 0.5 11.8 9.1 154 2 148 165 2.3 0 2.3 2.3 02/14/2006 16:40:00 10 0.4 11.1 8.8 9.9 0.4 10.7 8.8 10.1 0.4 11.1 8.8 151 2 148 165 2.2 0 2.6 2.3 02/14/2006 16:50:00 9.7 0.4 10.7 8.4 9.6 0.4 10.7 8 9.8 0.5 10.7 8.4 150 3 150 165 2.3 0 2.6 2.1 02/14/2006 17:00:00 10 0.3 10.7 8.8 9.9 0.3 10.7 8.8 10.2 0.4 11.1 8.8 151 2 153 165 2 0.1 2.3 1.8 02/14/2006 17:10:00 9.9 0.4 11.1 9.1 9.7 0.4 10.7 8.8 10.2 0.4 11.1 9.1 156 2 162 165 1.9 0 1.8 1.8 02/14/2006 17:20:00 9.1 0.3 10.3 8 8.9 0.3 9.5 8 9.4 0.3 10.3 8 159 3 157 165 1.9 0 2.1 1.8 02/14/2006 17:30:00 8.5 0.5 9.5 6.8 8.2 0.5 9.5 6.8 8.7 0.5 9.9 7.2 162 9 164 165 1.9 0 2.1 1.8 02/14/2006 17:40:00 8.4 0.5 9.5 6.8 8.1 0.5 9.1 6.8 8.5 0.5 9.5 6.8 162 3 162 165 1.8 0 1.8 1.6 02/14/2006 17:50:00 8.2 0.3 9.1 6.8 8 0.3 8.8 6.8 8.4 0.4 9.5 7.2 157 4 157 165 1.7 0 1.8 1.6 02/14/2006 18:00:00 8.4 0.3 9.1 7.6 8.3 0.3 9.1 7.2 8.5 0.4 9.5 7.2 152 2 156 165 1.6 0 1.6 1.4 02/14/2006 18:10:00 8 0.3 8.8 7.2 8 0.3 8.8 7.2 8 0.3 8.8 7.2 147 2 147 165 1.5 0 1.6 1.4 02/14/2006 18:20:00 7.2 0.7 8.8 6.1 7.2 0.6 8.8 6.1 7.2 0.8 8.8 4.6 142 4 148 165 1.5 0 1.6 1.4 02/14/2006 18:30:00 8 0.8 9.5 6.1 8.1 0.8 9.5 6.1 7.8 0.9 9.9 5.3 137 3 141 165 1.4 0 1.6 1.4 02/14/2006 18:40:00 6.7 1.1 8.4 3.8 6.7 1.1 8.4 4.2 6.5 1.1 8.8 4.2 138 4 145 165 1.4 0 1.6 1.4 02/14/2006 18:50:00 5.4 0.8 6.8 3.8 5.4 0.8 7.2 3.8 5.3 0.9 7.2 3.4 141 7 135 165 1.5 0 1.6 1.4 02/14/2006 19:00:00 4.5 0.7 6.1 2.3 4.6 0.7 6.1 2.3 4.3 0.8 5.7 1.9 143 10 147 165 1.8 0.1 1.8 1.6 02/14/2006 19:10:00 3.3 0.8 4.9 1.5 3.5 0.8 5.3 1.5 3.1 0.8 4.6 0.7 127 13 144 165 1.9 0 1.8 1.8 02/14/2006 19:20:00 1.7 0.9 4.2 0.4 1.9 0.8 4.2 0.4 1.8 0.8 4.2 0.4 78 33 135 165 1.8 0 1.8 1.6 02/14/2006 19:30:00 6 1.8 9.5 1.9 6.1 1.7 9.5 2.3 6 1.7 9.1 2.3 128 14 138 165 1.8 0 1.8 1.6 02/14/2006 19:40:00 10.7 1 13 8 10.7 1 12.6 8.4 10.9 0.9 12.6 7.6 145 5 146 165 2 0 2.3 1.8 02/14/2006 19:50:00 8.6 2.1 12.2 4.9 8.7 2.1 12.2 4.6 8.5 2.2 12.6 4.9 147 5 147 165 2 0 2.3 1.8 02/14/2006 20:00:00 6.6 0.7 8 4.9 6.7 0.7 8.4 4.9 6.5 0.7 8.4 4.6 144 5 150 165 2 0 2.3 1.8 02/14/2006 20:10:00 6.6 1 8 3 6.7 1 8.4 3.4 6.6 1 8.4 3.4 140 7 144 165 2.1 0 2.3 1.8 02/14/2006 20:20:00 6.5 0.7 8 4.6 6.5 0.7 8 4.9 6.4 0.8 8 4.6 143 6 145 165 2.1 0 2.3 2.1 02/14/2006 20:30:00 5.3 0.7 7.2 3 5.4 0.7 7.2 3.4 5.1 0.8 7.2 3.4 136 7 144 165 2.1 0 2.6 1.8 02/14/2006 20:40:00 6.9 0.7 8.4 4.9 7 0.6 8.4 5.3 6.9 0.6 8.4 4.9 136 6 133 165 2 0 2.3 1.8 02/14/2006 20:50:00 6.6 0.7 8.4 4.9 6.7 0.7 8.4 4.9 6.7 0.7 8.4 4.9 135 6 138 165 2.1 0 2.3 2.1 02/14/2006 21:00:00 6.7 1 8.8 3.4 6.9 1 9.1 3.8 6.7 1 8.8 3.8 129 6 127 165 2.3 0 2.3 2.1 02/14/2006 21:10:00 7.8 0.9 10.3 4.6 7.9 0.9 9.9 4.9 7.8 0.9 9.9 4.9 136 8 142 165 2.3 0 2.6 2.3 02/14/2006 21:20:00 7.2 1 9.5 4.6 7.3 1 9.5 4.6 7.1 1 9.9 4.2 132 7 129 165 2.4 0 2.6 2.3 02/14/2006 21:30:00 8.2 2.1 12.2 4.2 8.4 2.1 12.6 4.2 8.2 2.1 12.6 3.8 125 8 129 165 2.4 0 2.6 2.3 02/14/2006 21:40:00 6.9 1.1 9.5 4.6 7.1 1.1 9.9 4.2 6.7 1.2 9.1 3.4 125 8 129 165 2.4 0 2.6 2.6 02/14/2006 21:50:00 9.1 1.1 11.5 4.6 9.3 1.1 11.5 4.6 8.9 1.2 11.5 4.2 129 5 131 165 2.4 0 2.6 2.6 02/14/2006 22:00:00 8.4 1 11.1 6.5 8.5 1 10.7 6.5 8.3 1 11.5 6.1 132 8 137 165 2.5 0 2.8 2.6 02/14/2006 22:10:00 8.6 0.8 10.7 6.1 8.6 0.8 10.7 6.1 8.4 0.9 10.7 6.1 138 5 139 165 2.5 0 2.6 2.6 02/14/2006 22:20:00 8.6 0.6 10.3 6.8 8.7 0.7 10.7 6.8 8.6 0.7 11.1 6.8 138 6 119 165 2.4 0 2.6 2.3 02/14/2006 22:30:00 8.6 0.6 10.7 7.2 8.6 0.6 10.7 6.8 8.6 0.7 10.3 6.8 141 5 134 165 2.4 0 2.6 2.3 02/14/2006 22:40:00 8.2 0.7 9.9 6.1 8.2 0.7 9.5 6.1 8 0.8 9.9 5.7 143 6 145 165 2.4 0 2.6 2.3 02/14/2006 22:50:00 9.3 0.6 11.1 8 9.3 0.6 10.7 8 9.3 0.6 11.1 8 145 4 149 165 2.4 0 2.6 2.3 02/14/2006 23:00:00 8.4 0.7 10.3 6.5 8.4 0.7 9.9 6.1 8.2 0.7 9.9 6.1 147 5 153 165 2.4 0 2.6 2.3 02/14/2006 23:10:00 8.3 0.6 9.9 6.8 8.2 0.6 9.9 6.8 8.1 0.8 9.9 5.7 148 5 149 165 2.4 0 2.6 2.3 02/14/2006 23:20:00 8.2 0.7 9.5 6.5 8.1 0.6 9.5 6.5 8.1 0.8 9.9 6.5 148 4 154 165 2.4 0 2.6 2.3 02/14/2006 23:30:00 7.7 0.6 9.1 6.5 7.6 0.5 9.1 6.5 7.6 0.6 9.5 5.7 150 6 152 165 2.4 0 2.6 2.3 02/14/2006 23:40:00 8.1 0.7 9.9 6.5 8 0.7 9.5 6.5 8 0.7 9.9 6.5 152 4 153 165 2.4 0 2.6 2.3 02/14/2006 23:50:00 8.4 0.6 9.5 6.8 8.3 0.5 9.5 6.8 8.2 0.6 9.5 6.5 149 3 147 165 2.4 0 2.6 2.6 02/15/2006 00:00:00 8.9 0.6 10.7 7.2 8.8 0.6 10.3 7.2 8.7 0.6 10.3 6.8 149 3 150 165 2.4 0 2.8 2.6 02/15/2006 00:10:00 7.6 0.9 9.5 5.7 7.6 0.8 9.9 5.7 7.4 0.8 9.9 5.3 146 4 153 165 2.4 0 2.6 2.3 02/15/2006 00:20:00 7.9 0.9 10.3 6.5 7.9 1 10.3 6.1 7.9 1 10.3 6.1 144 4 142 165 2.4 0 2.6 2.3 02/15/2006 00:30:00 6.7 1.4 8.4 2.6 6.8 1.3 8.4 2.6 6.5 1.4 8.4 2.6 137 7 147 165 2.4 0 2.6 2.3 02/15/2006 00:40:00 6.9 1.7 9.9 2.6 6.8 1.7 9.9 2.6 6.9 1.8 9.9 2.6 145 6 153 165 2.4 0 2.6 2.3 02/15/2006 00:50:00 7.1 0.6 8.8 5.3 7.1 0.6 8.8 5.3 7.1 0.7 8.8 5.3 146 5 146 165 2.5 0 2.6 2.6 02/15/2006 01:00:00 6.1 0.8 8 4.2 6.1 0.8 7.6 4.6 6 0.9 8 4.2 145 5 148 165 2.4 0 2.6 2.3 02/15/2006 01:10:00 5.8 0.7 7.2 4.2 5.8 0.6 7.2 4.2 5.8 0.7 7.2 3.8 141 6 147 165 2.3 0 2.6 2.3 02/15/2006 01:20:00 6.9 0.6 8.4 4.9 6.9 0.6 8 4.9 6.7 0.5 8 5.3 145 4 150 165 2.2 0 2.6 2.1 02/15/2006 01:30:00 7.4 0.6 9.1 5.7 7.4 0.6 8.8 5.7 7.3 0.6 9.1 5.7 148 4 151 165 2.2 0 2.3 2.1 02/15/2006 01:40:00 8 0.5 9.1 6.5 8 0.5 9.1 6.8 8 0.5 9.1 6.5 150 4 158 165 2.3 0 2.3 2.1 02/15/2006 01:50:00 8.2 0.7 9.5 6.5 8.2 0.7 9.5 6.5 8.2 0.7 9.5 6.5 152 3 150 165 2.3 0 2.3 2.3 02/15/2006 02:00:00 8.6 0.7 9.9 6.5 8.5 0.6 9.9 6.8 8.6 0.6 10.3 6.5 157 6 157 165 2.4 0 2.6 2.3 02/15/2006 02:10:00 10.2 1 12.6 7.6 10.1 0.9 12.6 7.6 10.2 1 13 8 161 9 165 165 2.8 0.1 3.3 2.6 02/15/2006 02:20:00 11 0.8 13 8.4 10.7 0.8 12.2 8.4 10.9 0.9 13 8.8 165 9 165 165 3.1 0 3.3 3 02/15/2006 02:30:00 10.3 1 12.6 8 10.1 0.9 11.8 7.6 10.2 1 12.6 8 165 14 165 165 3.1 0 3.5 3 02/15/2006 02:40:00 8.4 0.8 10.7 5.7 8.2 0.7 10.7 6.1 8.4 0.7 10.3 6.5 161 5 165 165 3 0 3.3 2.8 02/15/2006 02:50:00 9 0.5 10.7 8 8.9 0.5 10.3 7.6 9.2 0.5 10.7 8 157 3 157 165 3 0 3.3 2.8 02/15/2006 03:00:00 9.3 0.5 10.7 8.4 9.2 0.4 10.7 8.4 9.2 0.5 10.7 7.6 157 3 161 165 3.1 0 3.3 3 02/15/2006 03:10:00 8.5 0.7 10.7 6.5 8.4 0.7 10.3 6.5 8.6 0.7 10.7 6.8 155 6 157 165 3.1 0 3.5 3 02/15/2006 03:20:00 7.7 0.8 9.5 5.7 7.6 0.7 9.5 6.1 7.6 0.9 9.5 4.2 150 6 157 165 3 0 3.3 2.8 02/15/2006 03:30:00 8 0.4 9.1 5.7 7.9 0.4 9.1 6.1 8 0.5 9.1 5.7 146 3 148 165 2.9 0 3 2.8 02/15/2006 03:40:00 8.3 0.5 9.1 7.2 8.2 0.4 9.1 6.8 8.4 0.5 9.5 6.8 151 3 152 165 2.9 0 3 2.8 02/15/2006 03:50:00 8.8 0.5 9.9 8 8.7 0.5 9.9 8 8.9 0.5 9.9 7.2 150 1 149 165 2.7 0 3 2.6 02/15/2006 04:00:00 8.9 0.3 9.5 8 8.8 0.3 9.5 7.6 9 0.4 9.9 8 150 2 149 165 2.7 0 2.8 2.6 02/15/2006 04:10:00 9.5 0.4 10.3 8.4 9.3 0.4 9.9 8 9.5 0.4 10.7 8.4 156 2 155 165 2.6 0 2.8 2.6 02/15/2006 04:20:00 8.9 0.5 9.9 7.2 8.7 0.5 9.9 7.2 8.9 0.4 10.3 8 157 3 157 165 2.7 0 2.8 2.6 02/15/2006 04:30:00 7.7 0.5 9.1 6.5 7.5 0.5 8.8 6.5 7.6 0.6 9.5 6.1 154 3 159 165 2.6 0 2.8 2.6 02/15/2006 04:40:00 7.4 0.3 8 6.5 7.4 0.3 8 6.5 7.3 0.4 8.4 5.7 149 3 152 165 2.6 0 2.8 2.6 02/15/2006 04:50:00 7.5 0.4 8.4 6.1 7.5 0.4 8.4 6.1 7.5 0.4 8.4 6.5 145 2 144 165 2.4 0 2.6 2.6 02/15/2006 05:00:00 8 0.5 9.1 6.5 8 0.5 9.1 6.5 7.9 0.5 9.1 6.5 147 3 148 165 2.5 0 2.6 2.6 02/15/2006 05:10:00 8.6 0.5 9.9 7.2 8.7 0.5 9.9 7.2 8.6 0.6 9.9 6.1 144 3 143 165 2.5 0 2.8 2.6 02/15/2006 05:20:00 9.4 0.4 10.3 8.4 9.4 0.4 10.3 8 9.4 0.5 10.7 7.6 147 2 148 165 2.5 0 2.8 2.6 02/15/2006 05:30:00 9.6 0.6 11.1 8 9.6 0.6 11.1 8 9.5 0.6 11.1 7.6 150 3 150 165 2.5 0 2.6 2.6 02/15/2006 05:40:00 10.4 0.6 11.8 8.4 10.3 0.5 11.8 8 10.2 0.7 11.5 8 150 3 152 165 2.6 0 2.8 2.6 02/15/2006 05:50:00 10 0.5 11.1 8.4 10 0.5 11.1 8 9.9 0.6 11.5 8 146 3 147 165 2.6 0 2.8 2.6 02/15/2006 06:00:00 10.7 0.6 12.2 8.8 10.6 0.6 11.8 8.8 10.5 0.7 12.2 8.4 149 4 153 165 2.6 0 2.8 2.6 02/15/2006 06:10:00 11.2 0.6 12.2 9.5 11.1 0.5 12.2 9.1 11 0.6 12.6 9.1 150 3 148 165 2.6 0 2.8 2.6 02/15/2006 06:20:00 10.7 0.4 11.8 9.5 10.7 0.4 11.5 9.5 10.7 0.5 11.8 9.1 149 2 151 165 2.5 0 2.8 2.6 02/15/2006 06:30:00 10.7 0.5 11.8 9.1 10.7 0.5 11.5 9.1 10.5 0.6 12.2 8.8 148 3 147 165 2.5 0 2.8 2.6 02/15/2006 06:40:00 11 0.4 11.8 9.9 11 0.4 11.8 9.9 11 0.5 12.2 9.5 144 3 143 165 2.4 0 2.6 2.6 02/15/2006 06:50:00 10.4 0.6 11.8 8.4 10.3 0.5 11.8 8.8 10.3 0.6 11.8 8 145 3 143 165 2.4 0 2.8 2.3 02/15/2006 07:00:00 10.7 0.5 11.8 9.1 10.6 0.5 11.8 9.1 10.6 0.6 11.8 9.1 148 3 147 165 2.4 0 2.6 2.3 02/15/2006 07:10:00 10.5 0.5 11.8 8.8 10.4 0.5 11.5 8.8 10.5 0.6 11.8 8.8 150 3 145 165 2.4 0 2.6 2.3 02/15/2006 07:20:00 9.5 0.6 11.1 7.6 9.4 0.6 11.1 8 9.6 0.7 11.5 7.6 148 3 150 165 2.4 0 2.6 2.3 02/15/2006 07:30:00 8.7 0.5 9.5 7.2 8.7 0.5 9.5 7.2 8.8 0.6 10.3 6.8 149 3 147 165 2.4 0 2.6 2.3 02/15/2006 07:40:00 7.4 0.6 8.8 6.1 7.3 0.6 8.8 6.1 7.5 0.5 9.1 6.5 152 3 149 165 2.4 0 2.6 2.3 02/15/2006 07:50:00 6.3 0.4 7.2 5.3 6.1 0.4 7.2 5.3 6.4 0.4 7.2 5.7 156 3 158 165 2.3 0 2.6 2.3 02/15/2006 08:00:00 6.2 0.4 7.2 5.3 6 0.3 6.8 4.9 6.3 0.4 7.2 5.3 157 3 154 165 2.3 0 2.6 2.3 02/15/2006 08:10:00 5.5 0.4 6.5 4.6 5.3 0.4 6.1 4.6 5.6 0.4 6.5 4.6 159 3 157 165 2.2 0 2.3 2.1 02/15/2006 08:20:00 5.2 0.2 5.7 4.6 5.1 0.2 5.7 4.6 5.3 0.2 5.7 4.6 157 2 159 165 2.2 0 2.3 2.1 02/15/2006 08:30:00 5.4 0.3 6.1 4.6 5.2 0.3 5.7 4.6 5.4 0.3 6.1 4.6 158 3 157 165 2.2 0 2.3 2.1 02/15/2006 08:40:00 4.7 0.3 5.3 3.8 4.4 0.2 4.9 3.8 4.8 0.2 5.3 4.2 160 3 160 165 2.3 0 2.3 2.3 02/15/2006 08:50:00 4.5 0.3 5.3 3.4 4.3 0.3 4.9 3.4 4.5 0.3 4.9 3.4 156 4 155 165 2.4 0 2.6 2.3 02/15/2006 09:00:00 4.9 0.3 5.3 4.2 4.7 0.3 5.3 4.2 5 0.3 5.7 4.2 155 3 153 165 2.4 0 2.6 2.3 02/15/2006 09:10:00 5 0.3 5.7 4.2 4.9 0.3 5.7 3.8 5 0.3 6.1 4.2 153 3 150 165 2.4 0 2.6 2.3 02/15/2006 09:20:00 6 0.3 6.5 4.9 6 0.3 6.5 5.3 6.1 0.3 6.5 5.3 146 3 145 165 2.6 0 2.8 2.6 02/15/2006 09:30:00 6.4 0.5 7.6 4.9 6.4 0.4 7.6 5.3 6.4 0.5 7.6 4.9 145 5 147 165 2.7 0 2.8 2.6 02/15/2006 09:40:00 6.9 0.7 8 5.3 6.8 0.6 8 4.9 6.9 0.7 8.4 5.3 149 3 150 165 2.7 0 2.8 2.8 02/15/2006 09:50:00 7.7 0.5 9.1 6.8 7.6 0.5 8.8 6.5 7.8 0.5 9.1 6.5 150 3 147 165 2.8 0 2.8 2.8 02/15/2006 10:00:00 9.4 0.6 11.1 7.6 9.4 0.6 11.1 8 9.4 0.7 10.7 7.6 147 3 148 165 2.9 0 3 2.8 02/15/2006 10:10:00 10.3 0.5 11.8 8.8 10.3 0.5 11.5 8.8 10.3 0.5 11.5 8.8 145 3 140 165 2.9 0 3 2.8 02/15/2006 10:20:00 10.9 0.5 12.2 9.5 11 0.5 12.2 9.5 10.9 0.6 12.6 9.1 144 3 144 165 2.9 0 3 2.8 02/15/2006 10:30:00 11.2 0.5 12.6 9.5 11.3 0.5 12.2 9.9 11.2 0.6 12.6 9.1 142 3 145 165 2.9 0 3 2.8 02/15/2006 10:40:00 11.7 0.6 13.3 9.9 11.8 0.6 13.3 9.5 11.6 0.8 13.3 8.8 142 3 142 165 2.9 0 3 2.8 02/15/2006 10:50:00 12.2 0.7 13.7 9.9 12.2 0.7 13.7 9.9 12 0.9 13.7 9.1 144 3 151 165 2.9 0 3 2.8 02/15/2006 11:00:00 12.5 0.7 14.1 10.7 12.5 0.7 14.1 10.7 12.3 0.8 14.1 9.5 145 4 144 165 2.9 0 3 2.8 02/15/2006 11:10:00 13.4 0.7 14.9 11.5 13.4 0.7 14.9 11.1 13.3 0.9 15.3 9.9 146 3 148 165 2.7 0 2.8 2.8 02/15/2006 11:20:00 13.7 0.7 15.6 11.1 13.7 0.7 15.6 11.5 13.7 0.8 15.6 11.5 145 3 147 165 2.7 0 3 2.6 02/15/2006 11:30:00 14.5 0.6 16.1 12.6 14.6 0.6 16.1 12.6 14.7 0.8 16.1 11.8 146 3 150 165 2.7 0 2.8 2.6 02/15/2006 11:40:00 14.6 0.5 16.1 13 14.6 0.6 15.6 13 14.6 0.7 16.4 12.6 146 3 148 165 2.7 0 2.8 2.6 02/15/2006 11:50:00 14.6 0.7 16.1 12.6 14.7 0.7 16.1 12.6 14.7 0.7 16.1 11.8 148 3 149 165 2.6 0 2.8 2.6 02/15/2006 12:00:00 14 0.7 15.6 11.5 14.1 0.7 15.6 11.5 14 1 16.4 10.7 146 3 145 165 2.6 0 2.8 2.6 02/15/2006 12:10:00 14.3 0.5 15.6 12.2 14.3 0.5 15.6 12.6 14.3 0.7 16.4 12.2 147 3 147 165 2.5 0 2.8 2.6 02/15/2006 12:20:00 13.8 0.7 15.6 11.8 13.7 0.7 15.6 11.8 13.7 0.8 15.6 9.9 149 3 147 165 2.4 0 2.6 2.3 02/15/2006 12:30:00 13.6 0.8 15.6 11.1 13.6 0.8 15.6 11.1 13.5 1 15.6 10.3 149 3 153 165 2.4 0 2.6 2.6 02/15/2006 12:40:00 13.1 0.6 14.9 11.1 13.1 0.6 14.5 11.1 13.3 0.7 14.9 10.7 149 3 152 165 2.4 0 2.6 2.3 02/15/2006 12:50:00 14.1 0.7 15.6 11.5 14.1 0.7 15.6 11.8 14.2 0.8 16.1 11.5 148 3 152 165 2.4 0 2.6 2.3 02/15/2006 13:00:00 14.3 0.7 15.6 12.2 14.3 0.6 15.6 12.2 14.5 0.8 16.4 12.2 148 3 148 165 2.4 0 2.6 2.3 02/15/2006 13:10:00 14.6 0.6 16.4 12.6 14.5 0.6 16.1 12.2 14.8 0.7 16.1 12.6 148 3 154 165 2.4 0 2.6 2.3 02/15/2006 13:20:00 13.5 0.7 15.6 11.5 13.5 0.7 15.3 11.8 13.4 0.8 15.3 11.1 150 3 152 165 2.4 0 2.6 2.3 02/15/2006 13:30:00 13.8 0.7 15.3 11.8 13.8 0.6 15.3 12.2 14 0.8 15.6 11.5 148 4 148 165 2.3 0 2.6 2.3 02/15/2006 13:40:00 13.8 1 16.4 11.8 13.7 1 16.1 11.5 13.8 1.1 16.8 11.8 152 3 154 165 2.3 0 2.6 2.3 02/15/2006 13:50:00 13.2 0.5 14.9 11.5 13.1 0.5 14.9 11.1 13.3 0.6 14.9 11.8 151 3 153 165 2.3 0 2.6 2.3 02/15/2006 14:00:00 12.5 0.6 14.1 11.1 12.5 0.6 13.7 11.1 12.7 0.6 14.1 10.7 151 3 153 165 2.3 0 2.6 2.3 02/15/2006 14:10:00 12.7 0.5 14.1 11.1 12.7 0.5 14.1 11.1 12.8 0.5 14.5 11.1 151 3 150 165 2.3 0 2.6 2.3 02/15/2006 14:20:00 12.9 1.1 14.9 9.9 12.8 1.1 14.9 9.5 13 1.3 15.3 9.5 154 5 155 165 2.3 0 2.6 2.3 02/15/2006 14:30:00 12.8 0.8 14.9 10.7 12.7 0.8 14.5 11.1 13 0.9 14.9 10.7 155 14 165 165 2.3 0 2.6 2.3 02/15/2006 14:40:00 12 0.7 14.5 9.9 11.9 0.7 14.1 9.5 12.1 0.9 15.3 9.9 156 4 148 165 2.3 0 2.6 2.3 02/15/2006 14:50:00 12.8 0.9 14.9 9.1 12.7 0.9 14.5 9.5 13 0.9 14.5 9.5 155 4 155 165 2.3 0 2.6 2.3 02/15/2006 15:00:00 10.8 0.9 13 8.4 10.7 0.9 12.6 8 10.9 0.9 13 7.6 160 12 160 165 2.4 0 2.6 2.3 02/15/2006 15:10:00 11.2 1 14.1 9.1 11.1 0.9 13.7 9.1 11.3 1.1 14.1 8.8 160 6 153 165 2.4 0 2.6 2.3 02/15/2006 15:20:00 11.4 0.7 13.3 8.8 11.3 0.7 13.3 8.8 11.5 0.8 13.3 8.8 157 9 158 165 2.4 0 2.6 2.3 02/15/2006 15:30:00 10.7 0.8 12.2 8.8 10.6 0.8 12.2 8.8 10.8 0.9 12.6 8.4 155 4 153 165 2.4 0 2.6 2.3 02/15/2006 15:40:00 10.5 0.6 11.5 8.4 10.3 0.5 11.5 8 10.6 0.6 11.8 8 156 3 161 165 2.4 0 2.6 2.3 02/15/2006 15:50:00 9.5 0.7 11.5 7.6 9.4 0.8 11.5 7.2 9.6 0.8 12.2 7.2 153 7 139 165 2.4 0 2.6 2.3 02/15/2006 16:00:00 10 1.2 12.6 7.6 9.9 1.1 12.6 7.2 10.1 1.2 12.2 7.6 152 16 139 165 2.3 0 2.6 2.1 02/15/2006 16:10:00 9.8 0.9 11.8 8 9.7 0.9 11.5 7.6 10 1 11.8 8 151 7 154 165 2.3 0 2.3 2.1 02/15/2006 16:20:00 7.5 1.1 9.5 4.9 7.5 1.1 9.5 4.6 7.6 1.1 9.5 4.6 150 7 165 165 2.3 0 2.6 2.3 02/15/2006 16:30:00 5 0.7 6.8 3.4 5 0.6 6.5 3.4 5.3 0.7 7.2 3.8 154 14 170 165 2.1 0 2.6 2.1 02/15/2006 16:40:00 4.8 0.6 6.8 3.4 4.7 0.6 6.5 3 5 0.6 6.5 3.4 169 13 180 165 2.2 0 2.3 2.1 02/15/2006 16:50:00 5.2 0.5 6.5 3.8 5.1 0.5 6.5 3.4 5.3 0.6 6.8 3.4 171 12 173 165 2.1 0 2.3 1.8 02/15/2006 17:00:00 5.6 0.5 6.8 4.2 5.4 0.5 6.5 4.2 5.6 0.5 6.8 4.2 172 8 175 165 2.3 0 2.3 2.1 02/15/2006 17:10:00 5.2 0.5 6.5 3.8 5 0.5 6.1 3.8 5.4 0.4 6.5 4.2 169 14 166 165 2.3 0 2.3 2.1 02/15/2006 17:20:00 3.8 0.6 5.3 2.3 3.6 0.6 4.9 2.3 3.9 0.6 5.3 2.3 170 5 171 165 2.3 0 2.6 2.3 02/15/2006 17:30:00 3.8 0.5 4.9 2.6 3.7 0.5 4.9 2.6 3.9 0.5 5.3 2.6 177 6 181 165 2.4 0 2.6 2.3 02/15/2006 17:40:00 3.1 0.5 4.2 1.5 3 0.5 4.2 1.9 3.1 0.5 4.2 1.9 183 10 182 165 2.4 0 2.6 2.3 02/15/2006 17:50:00 3.2 0.4 4.2 1.9 3.1 0.3 3.8 2.3 3.3 0.4 4.2 2.3 178 9 187 165 2.4 0 2.6 2.3 02/15/2006 18:00:00 1.9 0.5 3.4 0.4 1.8 0.5 3 0.4 1.9 0.5 3 0.4 181 11 182 165 2.4 0 2.6 2.3 02/15/2006 18:10:00 0.9 0.8 3 0.4 0.9 0.8 3 0.4 1.1 1 3.8 0.4 176 51 190 165 2.4 0 2.6 2.3 02/15/2006 18:20:00 0.9 0.7 3 0.4 0.8 0.6 2.6 0.4 0.9 0.8 3 0.4 167 49 185 165 2.4 0 2.6 2.3 02/15/2006 18:30:00 0.9 0.5 2.3 0.4 0.9 0.5 1.9 0.4 0.7 0.5 1.9 0.4 210 33 189 165 2.4 0 2.6 2.3 02/15/2006 18:40:00 0.4 0.3 1.9 0.4 0.5 0.3 2.3 0.4 0.5 0.4 2.3 0.4 258 30 249 165 2.4 0 2.6 2.3 02/15/2006 18:50:00 2.4 0.5 4.2 1.1 2.3 0.5 4.9 1.1 2.6 0.5 4.6 1.5 186 27 235 165 2.6 0 2.8 2.6 02/15/2006 19:00:00 3.2 0.7 4.6 1.5 3 0.7 4.6 1.5 3.4 0.6 4.6 1.9 171 12 158 165 2.6 0 2.8 2.6 02/15/2006 19:10:00 4.9 1.2 9.5 3 4.7 1.2 9.1 3 4.9 1.1 8.8 3.4 167 9 169 165 2.8 0 3.3 2.6 02/15/2006 19:20:00 7.2 1.2 10.7 4.2 7 1.2 10.7 4.2 7.2 1.1 9.9 4.2 174 8 169 165 3.1 0 3.3 2.8 02/15/2006 19:30:00 9.1 1 11.5 6.5 8.8 0.9 11.1 6.5 9.1 0.9 11.5 7.2 174 9 175 165 3.3 0 3.5 3 02/15/2006 19:40:00 11 1.1 13.7 7.6 10.7 1 13.3 8 11 1.1 13.7 8 171 11 166 165 3.3 0 3.5 3.3 02/15/2006 19:50:00 12.6 0.8 14.9 10.3 12.3 0.8 14.5 10.7 12.8 0.8 14.9 11.1 164 15 207 165 3.3 0 3.5 3.3 02/15/2006 20:00:00 12.6 1.3 16.1 9.9 12.3 1.3 15.6 9.5 12.7 1.4 16.8 9.5 161 12 156 165 3.3 0 3.5 3.3 02/15/2006 20:10:00 12 1 15.3 9.9 11.8 1 14.9 9.5 12.3 0.9 14.9 9.9 166 10 158 165 3.5 0 3.5 3.3 02/15/2006 20:20:00 11.4 1.1 14.5 8.4 11.2 1 14.1 8.4 11.6 1.1 14.1 8.8 164 21 165 165 3.4 0 3.5 3.3 02/15/2006 20:30:00 10.2 0.9 12.2 7.6 10.1 0.8 11.8 7.6 10.3 0.8 12.2 8 163 13 161 165 3.4 0 3.5 3.3 02/15/2006 20:40:00 9.8 0.9 12.2 6.8 9.6 0.8 11.8 7.2 9.7 1 11.8 6.1 162 8 170 165 3.5 0 3.5 3.3 02/15/2006 20:50:00 7.8 1.1 11.1 5.7 7.7 1 10.7 5.3 7.8 1.1 10.7 5.7 163 16 328 165 3.5 0 3.5 3.3 02/15/2006 21:00:00 7.4 0.6 8.8 5.7 7.2 0.6 8.8 5.7 7.5 0.6 9.1 6.1 166 6 165 165 3.5 0 3.8 3.3 02/15/2006 21:10:00 7 0.5 8 5.3 6.7 0.5 7.6 5.3 7 0.5 8 5.7 169 7 167 165 3.5 0 3.5 3.5 02/15/2006 21:20:00 7.1 0.5 8.4 5.3 6.7 0.4 7.6 4.9 7.1 0.4 8 6.1 172 4 173 165 3.5 0 3.5 3.5 02/15/2006 21:30:00 6.2 0.6 7.6 4.6 5.9 0.6 6.8 4.6 6.1 0.6 7.6 4.6 171 4 177 165 3.5 0 3.5 3.5 02/15/2006 21:40:00 4.7 0.6 5.7 3 4.5 0.6 5.7 2.6 4.8 0.6 5.7 2.6 165 10 165 165 3.4 0 3.5 3.3 02/15/2006 21:50:00 4.4 1 6.5 2.3 4.3 1 6.1 1.9 4.6 0.9 6.8 2.6 167 8 170 165 3.5 0 3.5 3.3 02/15/2006 22:00:00 3.3 0.6 4.6 1.5 3.2 0.5 4.2 1.5 3.6 0.5 4.9 2.3 171 9 165 165 3.5 0.1 3.5 3.3 02/15/2006 22:10:00 2.5 0.6 3.4 0.4 2.5 0.6 3.4 0.4 2.5 0.7 3.4 0.4 183 13 168 165 3.5 0 3.8 3.5 02/15/2006 22:20:00 3 0.4 4.2 2.3 3.1 0.4 4.2 2.3 3.1 0.5 4.2 1.9 196 5 189 165 3.6 0 3.8 3.5 02/15/2006 22:30:00 2.7 0.6 4.2 1.1 2.7 0.6 4.2 1.1 2.5 0.8 3.8 0.7 207 9 191 165 3.5 0 3.5 3.3 02/15/2006 22:40:00 3.1 0.6 4.2 1.5 3 0.5 4.2 1.5 3.1 0.7 4.2 1.1 191 11 188 165 3.5 0 3.8 3.5 02/15/2006 22:50:00 3.4 1 4.9 1.1 3.2 0.9 4.9 0.7 3.3 1 4.9 1.1 188 14 178 165 3.5 0 3.5 3.5 02/15/2006 23:00:00 5.5 0.6 6.8 4.2 5.2 0.6 6.5 3.8 5.5 0.6 6.8 4.2 175 5 178 165 3.5 0 3.5 3.5 02/15/2006 23:10:00 5.5 0.5 6.1 3.4 5.2 0.5 6.1 3 5.5 0.5 6.1 3.4 176 4 179 165 3.5 0 3.5 3.3 02/15/2006 23:20:00 5.2 0.2 5.7 4.2 5 0.2 5.7 4.2 5.1 0.3 6.1 4.6 170 8 180 165 3.4 0 3.5 3.3 02/15/2006 23:30:00 4.6 0.5 5.7 3.4 4.4 0.5 5.3 3 4.6 0.5 5.7 3.4 164 7 160 165 3.3 0.1 3.5 3 02/15/2006 23:40:00 4.6 0.4 5.3 3.4 4.4 0.4 4.9 3.4 4.6 0.4 5.3 3.8 166 6 165 165 3.3 0 3.5 3.3 02/15/2006 23:50:00 3.7 0.4 4.6 2.6 3.5 0.4 4.6 2.6 3.6 0.5 4.9 2.3 170 12 163 165 3.3 0 3.5 3.3 02/16/2006 00:00:00 2.9 0.3 3.4 1.9 2.7 0.3 3.4 1.9 2.7 0.3 3.4 1.9 174 5 169 165 3.3 0 3.5 3.3 02/16/2006 00:10:00 3.5 0.3 4.2 2.6 3.4 0.3 3.8 2.6 3.5 0.3 4.2 2.6 180 3 176 165 3.3 0 3.5 3.3 02/16/2006 00:20:00 2.8 0.7 3.8 1.5 2.7 0.6 3.8 1.5 3 0.7 4.2 1.5 180 2 181 165 3.3 0 3.5 3.3 02/16/2006 00:30:00 1.1 0.6 2.3 0.4 1.2 0.6 2.3 0.4 1.2 0.4 2.3 0.4 167 13 145 165 3.2 0 3.5 3 02/16/2006 00:40:00 0.9 0.6 2.3 0.4 1 0.6 2.3 0.4 0.9 0.6 2.3 0.4 196 12 182 165 3.5 0.1 3.8 3.3 02/16/2006 00:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 213 15 165 165 3.8 0 4 3.5 02/16/2006 01:00:00 0.6 0.4 1.5 0.4 0.7 0.5 1.9 0.4 0.4 0.1 1.5 0.4 217 13 212 165 4 0 4.3 3.8 02/16/2006 01:10:00 0.6 0.4 1.9 0.4 0.6 0.4 1.9 0.4 0.5 0.3 1.5 0.4 303 51 346 165 3.8 0 4 3.5 02/16/2006 01:20:00 1.2 0.3 1.9 0.4 1 0.4 1.9 0.4 0.8 0.3 1.9 0.4 358 12 19 165 3.8 0 4 3.8 02/16/2006 01:30:00 1.4 0.5 2.3 0.4 1.4 0.6 2.6 0.4 1 0.6 2.3 0.4 12 12 22 165 3.9 0 4 3.8 02/16/2006 01:40:00 1.2 0.3 1.9 0.4 1.1 0.4 1.9 0.4 1.1 0.4 1.9 0.4 12 5 18 165 3.7 0 3.8 3.5 02/16/2006 01:50:00 0.7 0.4 1.9 0.4 0.7 0.5 1.9 0.4 0.7 0.4 1.5 0.4 13 5 18 165 3.7 0.1 4.3 3.5 02/16/2006 02:00:00 0.5 0.2 1.5 0.4 0.5 0.3 1.5 0.4 0.7 0.4 1.9 0.4 13 4 18 165 3.8 0.2 4.3 3.5 02/16/2006 02:10:00 0.4 0.1 1.1 0.4 0.4 0.2 1.5 0.4 0.7 0.4 1.5 0.4 16 9 18 165 3.6 0 3.8 3.5 02/16/2006 02:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0.2 1.5 0.4 309 27 165 165 4 0.1 4.3 3.5 02/16/2006 02:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 300 0 165 165 4.2 0 4.5 4.3 02/16/2006 02:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 293 16 165 165 4.1 0 4.3 4.3 02/16/2006 02:50:00 0.4 0.2 1.5 0.4 0.4 0.2 1.5 0.4 0.4 0.1 1.1 0.4 267 13 305 165 3.9 0 4.3 3.5 02/16/2006 03:00:00 0.9 0.5 2.3 0.4 1 0.5 2.3 0.4 0.7 0.4 2.6 0.4 314 13 321 165 3.6 0 3.8 3.5 02/16/2006 03:10:00 0.5 0.3 1.5 0.4 0.5 0.4 1.9 0.4 0.6 0.4 1.9 0.4 321 26 317 165 3.8 0.1 4 3.5 02/16/2006 03:20:00 1.1 0.7 2.3 0.4 0.8 0.5 2.3 0.4 1 0.6 2.3 0.4 354 16 338 165 3.9 0 4.3 3.8 02/16/2006 03:30:00 1.3 0.5 2.6 0.4 1 0.5 2.3 0.4 0.9 0.5 1.9 0.4 349 8 355 165 3.6 0 3.8 3.5 02/16/2006 03:40:00 1.8 0.4 3 0.7 1.8 0.5 3 0.4 1.5 0.4 2.3 0.4 331 20 305 165 3.6 0 3.8 3.5 02/16/2006 03:50:00 3.6 0.8 5.7 1.5 3.7 0.8 5.7 1.9 3.3 0.8 5.3 1.1 296 11 292 165 3.6 0.1 3.8 3.5 02/16/2006 04:00:00 5.4 0.8 7.2 3.4 5.5 0.8 7.2 3.4 4.7 0.8 7.2 3 299 7 297 165 3.6 0 3.8 3.5 02/16/2006 04:10:00 5.5 0.6 6.8 4.2 5.5 0.6 7.2 4.2 4.6 0.6 6.5 3 303 7 302 165 3.5 0 3.8 3.3 02/16/2006 04:20:00 4.8 0.7 6.5 3 4.8 0.7 6.5 3.4 4.4 0.7 6.8 2.6 304 11 297 165 3.5 0 3.5 3.5 02/16/2006 04:30:00 4.3 0.6 6.1 2.6 4.3 0.6 5.7 3 3.7 0.6 6.1 2.3 304 10 300 165 3.6 0 4 3.5 02/16/2006 04:40:00 5.5 0.6 6.5 4.2 5.6 0.6 6.5 4.2 4.3 0.6 6.1 3 297 4 294 165 3.6 0.1 3.8 3.5 02/16/2006 04:50:00 4.7 0.6 6.5 3.4 4.7 0.6 6.5 3.4 3.7 0.5 5.7 2.3 303 4 300 165 3.5 0 3.5 3.3 02/16/2006 05:00:00 4.1 0.5 5.7 3 4.2 0.5 5.7 3 3.6 0.6 5.3 2.3 304 5 289 165 3.5 0 3.5 3.5 02/16/2006 05:10:00 4.1 0.7 5.3 2.6 4.2 0.7 5.3 2.6 3.7 0.6 5.3 1.9 298 8 297 165 3.5 0 3.8 3.5 02/16/2006 05:20:00 4.6 0.4 5.7 3.4 4.8 0.4 5.7 3.4 4.5 0.6 6.5 2.6 291 3 284 165 3.4 0 3.5 3.3 02/16/2006 05:30:00 3.5 0.7 5.3 1.9 3.6 0.7 5.7 2.3 3.2 0.5 4.9 2.3 294 4 298 165 3.5 0.1 3.8 3.3 02/16/2006 05:40:00 4.6 0.4 5.3 3.8 4.7 0.4 5.3 3.8 3.7 0.6 4.9 2.3 291 4 295 165 3.2 0 3.5 3 02/16/2006 05:50:00 4.8 0.6 6.1 2.6 4.8 0.6 6.1 2.6 3.6 0.6 4.9 1.9 295 6 299 165 3 0 3.3 2.8 02/16/2006 06:00:00 4.3 0.5 5.3 3 4.4 0.5 5.3 3 3.4 0.6 4.9 1.9 297 6 304 165 3 0.1 3.3 2.8 02/16/2006 06:10:00 5.3 0.6 6.8 3.4 5.3 0.6 6.5 3 4.8 0.9 6.8 2.6 292 5 282 165 2.9 0 3 2.8 02/16/2006 06:20:00 4.8 0.6 6.1 3.8 4.9 0.6 6.1 3.8 4.9 0.7 6.5 3.4 287 5 287 165 2.9 0 3 2.8 02/16/2006 06:30:00 4.8 0.5 6.1 3.4 4.9 0.5 6.1 3.8 4.4 0.9 6.1 2.6 293 8 277 165 2.9 0 3.3 2.8 02/16/2006 06:40:00 3.8 0.4 5.3 2.3 3.8 0.5 5.3 2.3 3.5 0.5 4.6 1.9 301 7 305 165 2.9 0.1 3 2.8 02/16/2006 06:50:00 3.6 0.3 4.6 3 3.8 0.3 4.6 3 3.6 0.5 4.6 2.3 286 4 286 165 2.7 0 2.8 2.6 02/16/2006 07:00:00 3.4 0.4 4.6 2.6 3.5 0.4 4.6 2.6 3.3 0.6 4.9 1.9 289 4 297 165 2.9 0.1 3 2.6 02/16/2006 07:10:00 3.8 0.3 4.6 3 3.8 0.3 4.6 3 3.3 0.4 4.2 2.6 303 6 291 165 2.7 0 2.8 2.6 02/16/2006 07:20:00 2.8 0.5 4.2 1.5 2.9 0.4 4.2 1.5 2.7 0.5 4.2 1.5 298 8 305 165 2.8 0.2 3 2.6 02/16/2006 07:30:00 3.8 0.5 4.9 2.6 4 0.5 5.3 3 4.2 0.4 4.9 2.3 279 6 274 165 2.9 0.1 3.3 2.6 02/16/2006 07:40:00 2.4 0.5 3.4 1.1 2.5 0.5 3.4 1.1 2.4 0.5 3.4 1.1 313 11 307 165 2.4 0 2.6 2.3 02/16/2006 07:50:00 1.4 0.7 3.8 0.4 1.5 0.8 3.8 0.4 1.8 0.9 4.2 0.4 280 8 274 165 3.1 0.3 3.5 2.6 02/16/2006 08:00:00 0.5 0.3 1.5 0.4 0.6 0.3 1.9 0.4 0.5 0.2 1.5 0.4 280 94 293 165 3.5 0.1 3.8 3 02/16/2006 08:10:00 0.6 0.5 1.9 0.4 0.5 0.4 1.9 0.4 0.5 0.3 1.5 0.4 200 17 179 165 2.9 0 3.3 2.8 02/16/2006 08:20:00 1 0.5 2.3 0.4 0.9 0.5 1.9 0.4 1.1 0.5 2.3 0.4 155 8 162 165 2.4 0.1 2.8 2.3 02/16/2006 08:30:00 0.6 0.3 1.9 0.4 0.5 0.3 1.9 0.4 0.5 0.2 1.5 0.4 197 22 218 165 2.5 0 2.8 2.3 02/16/2006 08:40:00 0.8 0.6 2.3 0.4 0.9 0.6 2.3 0.4 0.8 0.5 2.3 0.4 224 32 236 165 2.8 0.1 3.3 2.6 02/16/2006 08:50:00 0.4 0.1 1.1 0.4 0.4 0.2 1.5 0.4 0.5 0.2 1.5 0.4 182 30 165 165 2.7 0 3 2.6 02/16/2006 09:00:00 1.2 0.3 1.9 0.4 1.2 0.3 1.9 0.4 1.2 0.4 1.9 0.4 110 5 122 165 2.7 0 2.8 2.6 02/16/2006 09:10:00 0.4 0.1 1.1 0.4 0.4 0.1 1.1 0.4 0.4 0.1 0.7 0.4 109 0 110 165 3 0.1 3.3 2.6 02/16/2006 09:20:00 1.1 0.6 2.3 0.4 1.1 0.6 2.3 0.4 1.1 0.7 2.3 0.4 121 7 126 165 2.9 0 3.3 2.8 02/16/2006 09:30:00 1.2 0.6 2.3 0.4 1.2 0.6 2.3 0.4 1.1 0.6 2.3 0.4 131 4 135 165 2.8 0 3 2.8 02/16/2006 09:40:00 0.6 0.4 1.5 0.4 0.8 0.4 1.9 0.4 0.7 0.3 1.5 0.4 91 38 126 165 2.7 0 2.8 2.6 02/16/2006 09:50:00 0.4 0.1 1.1 0.4 0.4 0 0.7 0.4 0.4 0.2 1.5 0.4 60 72 357 165 2.9 0 3 2.8 02/16/2006 10:00:00 0.4 0 0.4 0.4 0.4 0 0.7 0.4 0.4 0 0.4 0.4 27 36 165 165 3.3 0.1 3.5 2.8 02/16/2006 10:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 13 69 165 165 4 0.2 4.3 3.5 02/16/2006 10:20:00 0.4 0 0.7 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 128 2 128 165 4.3 0.2 4.8 4 02/16/2006 10:30:00 0.4 0.1 0.7 0.4 0.4 0.1 1.1 0.4 0.4 0 0.7 0.4 12 6 12 165 5.2 0.3 5.7 4.8 02/16/2006 10:40:00 0.6 0.4 1.5 0.4 0.6 0.3 1.5 0.4 0.7 0.4 1.5 0.4 341 41 354 165 5.4 0.2 5.7 5 02/16/2006 10:50:00 0.5 0.3 1.5 0.4 0.5 0.3 1.9 0.4 0.6 0.5 2.3 0.4 142 38 127 165 4.5 0.4 5.7 4 02/16/2006 11:00:00 0.4 0 0.4 0.4 0.4 0 0.7 0.4 0.4 0.2 1.1 0.4 108 27 165 165 4 0.2 4.5 3.5 02/16/2006 11:10:00 0.8 0.3 1.9 0.4 0.8 0.3 1.9 0.4 1 0.5 2.3 0.4 133 20 152 165 4.9 0.3 5.2 4.5 02/16/2006 11:20:00 1.6 0.8 3.4 0.4 1.5 0.8 3 0.4 1.7 0.7 3 0.4 133 9 135 165 5.1 0.1 5.5 4.8 02/16/2006 11:30:00 2.1 0.4 3 1.1 1.7 0.5 3.4 0.4 2.1 0.4 3 1.1 148 13 135 165 4.9 0 5.2 4.5 02/16/2006 11:40:00 1.8 0.4 3 1.1 1.7 0.4 3.4 1.1 1.9 0.5 3.4 1.1 133 8 143 165 3.9 0.4 4.8 3 02/16/2006 11:50:00 1.6 0.3 2.3 0.4 1.6 0.3 2.3 0.7 1.6 0.3 2.3 1.1 154 11 152 165 3 0.2 3.8 2.6 02/16/2006 12:00:00 1.2 0.5 2.3 0.4 1.2 0.5 2.3 0.4 1.1 0.5 2.3 0.4 145 4 149 165 3 0 3 2.8 02/16/2006 12:10:00 1.3 0.5 2.6 0.4 1.3 0.5 2.6 0.4 1 0.5 2.3 0.4 129 15 129 165 3 0 3.5 2.8 02/16/2006 12:20:00 0.9 0.4 1.9 0.4 0.9 0.4 1.5 0.4 0.7 0.4 1.5 0.4 115 16 121 165 3 0 3 2.8 02/16/2006 12:30:00 1.1 0.4 2.3 0.4 1.1 0.4 1.9 0.4 1.1 0.5 1.9 0.4 158 7 166 165 2.9 0 3 2.8 02/16/2006 12:40:00 0.6 0.4 1.9 0.4 0.6 0.4 1.9 0.4 0.6 0.4 1.9 0.4 158 13 161 165 2.8 0 3 2.8 02/16/2006 12:50:00 1.5 0.4 2.6 0.4 1.5 0.4 2.6 0.4 1.5 0.4 2.6 0.7 140 15 149 165 2.6 0 2.8 2.6 02/16/2006 13:00:00 1.1 0.3 1.9 0.4 1.2 0.3 1.9 0.4 1.3 0.3 2.3 0.4 161 8 151 165 2.9 0.1 3.3 2.6 02/16/2006 13:10:00 0.6 0.4 1.9 0.4 0.8 0.4 1.9 0.4 0.9 0.4 2.3 0.4 140 28 144 165 3.3 0 3.5 3 02/16/2006 13:20:00 1.5 0.5 3 0.4 1.6 0.5 3.4 0.4 1.7 0.5 3 0.4 152 15 146 165 3.2 0.2 3.5 2.8 02/16/2006 13:30:00 2.1 0.4 3 1.5 2.3 0.3 3 1.5 2.4 0.4 3.4 1.5 131 6 143 165 2.7 0.2 3.3 2.3 02/16/2006 13:40:00 1.6 0.3 2.3 0.4 1.8 0.3 2.6 0.7 1.9 0.3 2.6 1.1 119 11 107 165 2.3 0 2.6 2.3 02/16/2006 13:50:00 2.2 0.3 3 1.5 2.3 0.3 3 1.9 2.4 0.3 3 1.5 138 9 147 165 2.4 0 2.6 2.3 02/16/2006 14:00:00 2.4 0.3 3 1.5 2.5 0.3 3.4 1.5 2.6 0.3 3.4 1.9 147 6 145 165 2.4 0 2.6 2.3 02/16/2006 14:10:00 2.6 0.6 4.6 1.1 2.7 0.5 4.2 1.5 2.7 0.6 3.8 1.1 135 14 157 165 2.4 0 2.8 2.3 02/16/2006 14:20:00 2.4 0.8 4.2 0.7 2.6 0.7 4.2 1.1 2.7 0.7 4.6 1.1 150 9 148 165 2.4 0 2.6 2.3 02/16/2006 14:30:00 2.2 0.8 3.8 0.4 2.3 0.7 3.8 0.7 2.5 0.8 4.2 0.4 159 17 166 165 2.4 0 2.6 2.3 02/16/2006 14:40:00 2.2 0.7 3.4 0.4 2.4 0.6 4.2 0.7 2.3 0.8 3.8 0.4 150 11 150 165 2.4 0 2.6 2.3 02/16/2006 14:50:00 3.1 0.7 4.2 1.1 3.1 0.6 4.6 1.5 3.2 0.7 4.6 1.1 158 8 152 165 2.3 0 2.8 2.1 02/16/2006 15:00:00 2.1 0.5 3 0.7 2.3 0.4 3.4 1.1 2.2 0.6 3.4 0.4 165 11 149 165 2.3 0 2.6 2.1 02/16/2006 15:10:00 3 0.5 4.2 1.9 3.1 0.4 4.2 2.3 3.2 0.5 4.6 2.3 173 7 179 165 2.3 0 2.6 2.1 02/16/2006 15:20:00 2.9 0.6 4.2 1.5 2.9 0.5 4.6 1.5 3.1 0.5 4.6 2.3 171 10 172 165 2 0.1 2.3 1.8 02/16/2006 15:30:00 2.6 0.6 4.2 1.5 2.7 0.5 4.2 1.5 2.8 0.5 4.2 1.9 167 11 165 165 2 0 2.1 1.8 02/16/2006 15:40:00 1.9 0.5 3.4 0.4 2.1 0.4 3.8 1.1 2.1 0.4 3.8 1.1 167 8 165 165 2 0 2.3 1.8 02/16/2006 15:50:00 2.8 0.7 4.2 1.1 3 0.6 4.2 1.5 3 0.7 4.6 1.5 180 9 176 165 2 0 2.1 1.8 02/16/2006 16:00:00 1.9 1 4.2 0.4 2.1 0.9 3.8 0.4 2.1 1.1 4.2 0.4 171 12 183 165 1.9 0 1.8 1.8 02/16/2006 16:10:00 1.3 0.5 2.3 0.4 1.6 0.4 2.6 0.7 1.4 0.4 2.3 0.4 171 10 181 165 1.9 0 2.1 1.8 02/16/2006 16:20:00 1.8 0.8 4.2 0.4 2 0.7 4.2 0.7 1.7 0.9 4.2 0.4 173 8 173 165 2 0 2.3 1.8 02/16/2006 16:30:00 1.8 0.8 3.4 0.4 2 0.7 3.4 0.7 2 0.9 4.6 0.4 137 17 168 165 1.8 0 1.8 1.6 02/16/2006 16:40:00 1.7 0.5 3.4 0.4 1.9 0.4 3.4 1.1 1.8 0.5 3 0.7 139 18 169 165 1.8 0 1.8 1.6 02/16/2006 16:50:00 1.4 1.1 4.2 0.4 1.5 1.1 4.2 0.4 1.4 1.2 3.8 0.4 162 15 158 165 1.8 0 2.1 1.6 02/16/2006 17:00:00 1.2 0.4 2.3 0.4 1.5 0.3 2.3 0.7 1 0.5 1.9 0.4 158 11 143 165 1.8 0 1.8 1.6 02/16/2006 17:10:00 2.4 0.8 4.2 0.7 2.5 0.8 4.2 1.1 2.4 0.9 4.2 0.4 143 10 142 165 1.7 0 1.8 1.6 02/16/2006 17:20:00 2.5 0.6 3.8 0.4 2.6 0.5 3.8 1.1 2.6 0.6 4.2 1.5 137 12 122 165 1.6 0 1.8 1.4 02/16/2006 17:30:00 1.5 0.8 3 0.4 1.7 0.7 3 0.4 1.4 0.9 3 0.4 123 20 114 165 1.6 0 1.6 1.6 02/16/2006 17:40:00 2 0.7 3.4 0.4 2.2 0.7 3.8 0.4 2 0.8 3.4 0.4 106 15 119 165 1.6 0 1.6 1.6 02/16/2006 17:50:00 1.5 1.3 4.2 0.4 1.6 1.3 4.6 0.4 1.6 1.4 4.2 0.4 114 16 91 165 1.4 0 1.6 1.4 02/16/2006 18:00:00 0.5 0.3 1.5 0.4 0.6 0.4 1.9 0.4 0.5 0.3 1.5 0.4 142 28 148 165 1.5 0 1.6 1.4 02/16/2006 18:10:00 0.5 0.3 1.5 0.4 0.7 0.4 1.5 0.4 0.6 0.3 1.5 0.4 356 98 21 165 1.5 0 1.6 1.4 02/16/2006 18:20:00 1.8 0.9 3.4 0.4 2.1 0.8 3.4 0.7 1.8 1 3.8 0.4 78 18 61 165 1.3 0 1.6 1.1 02/16/2006 18:30:00 1.6 1.1 3.8 0.4 1.8 1 3.8 0.4 1.5 1.1 4.2 0.4 85 30 54 165 1.1 0 1.4 1.1 02/16/2006 18:40:00 2.5 0.6 3.8 0.4 2.6 0.6 3.8 0.7 2.5 0.7 4.2 0.4 93 9 98 165 1.2 0 1.4 1.1 02/16/2006 18:50:00 2.4 0.8 4.2 0.4 2.6 0.7 4.2 0.7 2.6 0.7 3.8 0.7 94 1 94 165 0.9 0 1.4 0.9 02/16/2006 19:00:00 2.5 0.9 4.2 0.4 2.7 0.8 4.6 0.7 2.5 0.8 4.6 0.7 94 0 94 165 0.9 0 1.1 0.9 02/16/2006 19:10:00 3 0.5 4.6 1.9 3.1 0.5 4.6 1.9 3 0.5 4.6 1.9 94 0 94 165 1.1 0 1.4 0.9 02/16/2006 19:20:00 2.8 0.5 4.6 1.9 2.9 0.5 4.6 1.9 2.7 0.5 4.2 1.9 94 0 94 165 1.1 0 1.4 0.9 02/16/2006 19:30:00 2.5 0.9 4.2 0.4 2.7 0.9 4.2 0.4 2.5 0.8 4.2 0.4 94 0 94 165 1.1 0 1.4 1.1 02/16/2006 19:40:00 2.6 0.5 3.8 1.1 2.7 0.6 4.2 1.1 2.6 0.5 4.2 1.1 94 0 94 165 1.1 0 1.4 0.9 02/16/2006 19:50:00 2.7 0.9 4.9 1.5 2.8 0.9 4.9 1.5 2.6 0.8 4.9 1.1 94 0 94 165 1.1 0 1.4 1.1 02/16/2006 20:00:00 3.1 0.7 5.3 1.1 3.2 0.7 5.3 1.5 3 0.7 5.3 1.1 94 0 94 165 1.1 0 1.4 0.9 02/16/2006 20:10:00 2.8 0.6 4.2 1.1 2.9 0.6 4.6 1.5 2.8 0.6 4.2 0.7 94 0 94 165 1.2 0 1.4 1.1 02/16/2006 20:20:00 2.5 0.5 3.8 1.1 2.7 0.5 3.8 1.1 2.3 0.6 4.2 0.7 94 0 94 165 1.1 0 1.4 1.1 02/16/2006 20:30:00 3.7 0.5 5.3 2.6 3.9 0.5 5.7 3 3.6 0.5 5.3 2.6 94 0 94 165 1.2 0 1.4 1.1 02/16/2006 20:40:00 2.8 0.6 4.6 1.5 3 0.6 4.6 1.9 2.9 0.6 4.9 1.9 94 0 94 165 1.2 0 1.4 1.1 02/16/2006 20:50:00 2.6 0.4 3.4 1.9 2.7 0.4 3.8 1.9 2.5 0.4 3.8 1.5 94 0 94 165 1.2 0 1.4 1.1 02/16/2006 21:00:00 3.7 0.7 5.3 1.9 3.8 0.7 5.3 1.9 3.4 0.7 4.9 1.9 94 0 94 165 1.2 0 1.4 1.1 02/16/2006 21:10:00 3.4 0.7 4.9 1.9 3.5 0.7 4.9 1.9 3.3 0.6 4.9 1.9 94 0 94 165 1.4 0 1.6 1.4 02/16/2006 21:20:00 3 0.5 4.6 1.9 3.1 0.5 4.6 1.9 3 0.4 4.2 1.9 94 0 94 165 1.4 0 1.6 1.4 02/16/2006 21:30:00 3.6 0.6 5.3 2.3 3.8 0.6 5.3 2.6 3.6 0.6 5.3 2.3 94 0 94 165 1.4 0 1.4 1.1 02/16/2006 21:40:00 3.2 0.5 4.6 1.9 3.3 0.5 4.6 1.9 3.1 0.5 4.2 1.9 93 0 94 165 1.4 0 1.6 1.4 02/16/2006 21:50:00 3.2 0.6 4.9 1.9 3.3 0.6 4.9 1.9 2.9 0.5 4.2 1.5 92 1 92 165 1.4 0 1.6 1.4 02/16/2006 22:00:00 3.2 0.3 4.2 2.3 3.3 0.3 4.2 2.6 2.9 0.4 3.8 1.5 90 0 91 165 1.4 0 1.6 1.4 02/16/2006 22:10:00 3.5 0.2 3.8 3 3.5 0.2 4.2 3 3.3 0.3 3.8 2.3 88 2 90 165 1.4 0 1.6 1.4 02/16/2006 22:20:00 4 0.4 5.3 3.4 4.1 0.4 5.3 3.4 3.8 0.5 5.3 2.6 73 3 70 165 1.4 0 1.6 1.4 02/16/2006 22:30:00 4.3 0.5 5.3 2.6 4.4 0.5 5.7 3 4.1 0.4 5.3 3 65 1 66 165 1.5 0 1.6 1.4 02/16/2006 22:40:00 4.1 0.4 4.9 2.6 4.2 0.4 4.9 2.6 4.1 0.5 4.9 2.6 57 3 65 165 1.6 0 1.6 1.6 02/16/2006 22:50:00 4 0.5 4.9 3 4.1 0.5 4.9 3 3.9 0.5 4.9 2.6 59 3 54 165 1.6 0 1.6 1.6 02/16/2006 23:00:00 3.8 0.5 4.9 2.6 4 0.5 5.7 2.6 3.8 0.5 5.3 2.6 71 5 72 165 1.7 0 1.8 1.6 02/16/2006 23:10:00 4.3 0.5 5.3 2.6 4.5 0.5 5.7 3 4.1 0.5 5.3 2.3 99 5 84 165 1.8 0 1.8 1.6 02/16/2006 23:20:00 3.4 0.5 4.6 1.9 3.7 0.5 4.9 2.3 3.4 0.5 4.6 2.3 92 6 103 165 1.8 0 1.8 1.6 02/16/2006 23:30:00 3.2 0.5 4.2 1.9 3.3 0.5 4.6 1.9 3.1 0.5 4.2 1.9 74 7 87 165 1.8 0 1.8 1.8 02/16/2006 23:40:00 3.7 0.5 4.9 2.3 3.7 0.5 4.9 2.3 3.7 0.5 4.9 2.3 50 4 46 165 1.8 0 1.8 1.6 02/16/2006 23:50:00 3.4 0.5 5.3 2.3 3.5 0.5 4.9 2.3 3.4 0.5 4.6 2.3 46 1 45 165 1.8 0 1.8 1.6 02/17/2006 00:00:00 3.4 0.6 4.6 1.9 3.6 0.6 4.9 2.3 3.3 0.6 4.9 1.9 49 0 49 165 1.8 0 1.8 1.8 02/17/2006 00:10:00 3.9 0.5 4.9 2.6 4 0.5 5.3 2.3 3.9 0.5 5.3 2.6 54 2 54 165 1.8 0 1.8 1.6 02/17/2006 00:20:00 4.1 0.6 5.7 2.6 4.2 0.6 6.1 2.6 4 0.6 5.7 2.6 60 5 61 165 1.8 0 1.8 1.6 02/17/2006 00:30:00 4.2 0.5 5.7 3 4.4 0.5 5.7 3 4.2 0.5 5.7 3 65 6 77 165 1.9 0 1.8 1.8 02/17/2006 00:40:00 4.8 0.7 6.1 3 5 0.7 6.5 3 4.7 0.7 6.1 3 82 8 79 165 2 0 2.1 1.8 02/17/2006 00:50:00 5.8 0.6 7.2 4.2 6.1 0.6 7.2 4.6 5.7 0.6 7.2 3.8 90 5 88 165 2.1 0 2.3 2.1 02/17/2006 01:00:00 5.6 0.5 6.8 4.2 5.8 0.5 6.8 4.2 5.2 0.6 6.5 3.4 99 4 98 165 2.1 0 2.3 2.1 02/17/2006 01:10:00 5.8 0.6 7.2 3.8 6 0.6 7.2 4.2 5.4 0.7 6.8 3.4 101 5 107 165 2.2 0 2.3 2.1 02/17/2006 01:20:00 5.8 0.6 6.8 3.8 6 0.6 7.2 3.8 5.4 0.6 6.8 3.4 92 4 90 165 2.1 0 2.3 2.1 02/17/2006 01:30:00 6.1 0.6 7.2 4.6 6.3 0.6 7.6 4.9 5.7 0.6 6.8 4.2 85 5 87 165 2.3 0 2.3 2.3 02/17/2006 01:40:00 6.3 0.5 7.2 3.8 6.4 0.5 7.2 4.2 5.9 0.6 7.2 3.4 89 5 91 165 2.3 0 2.3 2.3 02/17/2006 01:50:00 6 0.8 8 3.8 6.1 0.8 8 3.8 5.7 0.7 8 3.8 90 7 92 165 2.2 0 2.6 2.1 02/17/2006 02:00:00 5.7 0.8 7.6 3.8 5.8 0.8 7.6 3.8 5.5 0.8 7.2 3.8 94 7 94 165 2.1 0 2.3 2.1 02/17/2006 02:10:00 6.3 0.6 7.2 4.6 6.4 0.6 7.6 4.6 6 0.7 7.6 3.8 90 6 89 165 2 0 2.3 1.8 02/17/2006 02:20:00 6.7 0.8 8.4 4.6 6.9 0.8 8.8 4.6 6.4 0.9 8 3.8 87 5 85 165 2 0 2.3 1.8 02/17/2006 02:30:00 8.1 0.5 9.1 6.5 8.2 0.5 9.5 6.5 7.8 0.6 9.1 6.1 91 5 88 165 2.2 0 2.3 2.1 02/17/2006 02:40:00 8.1 0.7 9.9 6.1 8.3 0.7 9.9 6.1 7.8 0.7 9.5 5.3 99 6 107 165 2.4 0 2.6 2.3 02/17/2006 02:50:00 8.6 0.9 11.1 5.7 8.7 0.9 11.1 6.5 8.2 1 10.7 5.3 110 6 116 165 2.7 0 2.8 2.6 02/17/2006 03:00:00 9 0.8 11.5 7.2 9.1 0.8 11.5 7.2 8.8 1 11.8 6.5 118 6 117 165 2.9 0 2.8 2.8 02/17/2006 03:10:00 10.5 1.3 12.6 7.2 10.5 1.3 13 7.2 10.4 1.4 12.6 6.5 137 12 111 165 2.9 0 3 2.8 02/17/2006 03:20:00 10.9 0.5 11.8 9.5 11 0.5 12.2 9.1 11 0.6 12.6 9.1 152 3 150 165 2.4 0.1 2.8 2.1 02/17/2006 03:30:00 9.5 0.6 11.1 7.6 9.5 0.6 11.1 7.6 9.4 0.7 11.1 7.6 151 3 151 165 2 0.1 2.3 1.8 02/17/2006 03:40:00 7.7 0.7 9.5 6.1 7.7 0.7 9.5 6.1 7.8 0.7 9.5 5.7 147 3 151 165 1.8 0 1.8 1.6 02/17/2006 03:50:00 8.6 0.7 9.9 6.5 8.7 0.8 9.9 6.1 8.5 0.8 9.9 6.1 147 3 148 165 1.7 0 1.8 1.6 02/17/2006 04:00:00 8.2 0.6 9.5 6.5 8.2 0.6 9.5 6.8 8.2 0.7 9.9 5.7 147 0 147 165 1.7 0 1.8 1.6 02/17/2006 04:10:00 7.3 0.4 8.8 5.7 7.4 0.4 8.8 6.1 7.4 0.5 8.8 5.7 147 0 147 165 1.7 0 1.8 1.6 02/17/2006 04:20:00 7.3 0.4 8 6.5 7.4 0.4 8.4 6.1 7.4 0.5 8.4 5.7 147 0 147 165 1.7 0 1.6 1.6 02/17/2006 04:30:00 6.4 0.4 8 5.3 6.5 0.4 8 5.3 6.4 0.5 7.6 4.9 147 0 147 165 1.6 0 1.8 1.6 02/17/2006 04:40:00 7.6 0.8 9.1 6.1 7.7 0.7 9.1 6.1 7.6 0.8 9.5 5.7 147 0 147 165 1.6 0 1.6 1.6 02/17/2006 04:50:00 7.7 0.6 9.1 6.5 7.8 0.6 9.1 6.5 7.8 0.5 9.1 6.5 147 0 147 165 1.5 0.1 1.8 1.4 02/17/2006 05:00:00 7.7 0.4 8.8 6.5 7.7 0.4 8.8 6.8 7.8 0.5 8.8 6.5 147 0 147 165 1.4 0 1.4 1.4 02/17/2006 05:10:00 7.6 0.6 9.1 6.1 7.5 0.6 9.1 6.1 7.7 0.6 9.1 6.1 147 0 147 165 1.2 0 1.4 1.1 02/17/2006 05:20:00 7.7 0.4 8.8 6.5 7.6 0.4 8.8 6.5 8 0.4 9.1 6.5 147 0 147 165 1.3 0 1.4 1.4 02/17/2006 05:30:00 7.8 0.5 9.1 6.5 7.9 0.5 9.1 6.5 8.1 0.5 9.1 6.5 147 0 147 165 1.3 0 1.4 1.4 02/17/2006 05:40:00 8.2 0.5 9.5 6.8 8.3 0.5 9.5 6.8 8.4 0.6 9.9 6.8 147 0 147 165 1.3 0 1.4 1.4 02/17/2006 05:50:00 8.2 0.6 9.5 6.8 8.2 0.6 9.5 6.8 8.3 0.6 9.5 6.5 147 0 147 165 1.4 0 1.4 1.4 02/17/2006 06:00:00 7.7 0.7 9.5 5.7 7.8 0.6 9.9 5.7 7.8 0.6 9.5 6.1 147 0 147 165 1.4 0 1.6 1.4 02/17/2006 06:10:00 8.2 0.7 10.3 6.5 8.2 0.7 9.9 6.5 8.3 0.7 9.9 6.5 147 0 147 165 1.5 0 1.6 1.4 02/17/2006 06:20:00 7.1 1 9.9 5.3 7.1 1 9.5 5.3 7.2 1 9.5 5.3 147 0 147 165 1.6 0 1.8 1.6 02/17/2006 06:30:00 6.8 1.2 10.3 4.6 6.8 1.2 10.7 4.6 6.7 1.1 10.7 4.6 147 0 147 165 1.7 0 1.8 1.6 02/17/2006 06:40:00 8.5 1 11.8 6.1 8.4 1 11.8 6.1 8.4 1 11.8 6.1 147 0 147 165 1.7 0 1.8 1.6 02/17/2006 06:50:00 9.3 0.9 11.8 6.5 9.3 0.8 11.8 6.8 9.5 0.8 11.5 6.8 147 0 147 165 1.8 0 1.8 1.8 02/17/2006 07:00:00 11 1.5 14.1 7.2 11.1 1.5 14.1 7.6 10.8 1.4 13.7 8 147 0 147 165 2 0 2.3 1.8 02/17/2006 07:10:00 13.4 0.6 14.9 11.8 13.4 0.7 14.9 11.5 13.3 0.8 15.3 10.7 147 0 147 165 2.4 0 2.6 2.3 02/17/2006 07:20:00 12.2 0.7 14.1 10.3 12.3 0.7 14.1 10.7 12.4 0.8 14.1 10.3 152 4 150 165 2.4 0 2.6 2.3 02/17/2006 07:30:00 12.5 0.7 14.1 10.7 12.4 0.8 14.1 10.7 12.6 0.8 14.5 10.3 153 5 154 165 2.4 0 2.6 2.3 02/17/2006 07:40:00 14 0.8 16.1 11.8 14.1 0.8 16.1 11.8 13.9 1.1 16.4 10.7 149 3 155 165 2.3 0 2.6 2.3 02/17/2006 07:50:00 13.6 1.1 15.6 10.7 13.7 1.1 15.6 9.9 13.5 1.3 15.6 9.9 150 4 154 165 2.2 0 2.3 2.1 02/17/2006 08:00:00 15.1 1 16.8 12.2 15.2 0.9 16.8 12.6 15 1 17.2 12.2 148 5 148 165 2.2 0 2.3 2.1 02/17/2006 08:10:00 15.4 0.9 17.2 12.6 15.4 0.9 17.2 12.6 15.2 1.2 17.2 10.7 149 3 145 165 2.1 0 2.3 2.1 02/17/2006 08:20:00 14.3 0.9 16.4 11.5 14.3 0.9 16.8 11.5 14.1 1.1 16.4 10.7 147 4 148 165 2.1 0 2.3 2.1 02/17/2006 08:30:00 14.7 0.7 16.8 12.6 14.7 0.7 16.4 12.6 14.5 0.8 16.1 11.8 147 4 146 165 2 0 2.3 1.8 02/17/2006 08:40:00 14.5 0.6 15.6 12.2 14.6 0.6 15.6 12.2 14.5 0.9 16.8 11.8 148 3 149 165 1.8 0 1.8 1.8 02/17/2006 08:50:00 14.8 0.7 16.8 11.8 14.8 0.7 16.4 11.8 14.8 0.8 16.8 11.5 146 5 151 165 1.8 0 1.8 1.6 02/17/2006 09:00:00 14.6 0.6 16.1 12.6 14.7 0.7 16.1 12.6 14.9 1 16.4 11.1 144 4 145 165 1.7 0 1.8 1.6 02/17/2006 09:10:00 12.8 0.8 14.5 10.3 12.7 0.8 14.5 9.9 12.7 1 14.9 9.5 144 3 146 165 1.7 0 1.8 1.6 02/17/2006 09:20:00 12.2 0.6 13.7 10.3 12.1 0.6 13.7 10.3 12.1 0.8 13.7 8.8 144 0 145 165 1.7 0 1.6 1.6 02/17/2006 09:30:00 11.9 0.6 13.3 9.9 11.8 0.6 13.3 10.3 11.9 0.7 13.3 9.5 145 0 145 165 1.6 0 1.8 1.6 02/17/2006 09:40:00 11.1 0.5 12.2 9.5 11 0.5 12.6 9.5 11.2 0.6 13 9.1 145 0 145 165 1.6 0 1.8 1.6 02/17/2006 09:50:00 10.2 0.6 11.5 8.4 10.2 0.5 11.5 8.4 10.3 0.6 11.8 8.4 145 0 145 165 1.5 0 1.6 1.4 02/17/2006 10:00:00 9.3 0.5 10.7 8 9.3 0.5 10.7 8.4 9.4 0.5 10.7 7.6 145 0 145 165 1.5 0 1.6 1.4 02/17/2006 10:10:00 8.4 0.6 10.3 7.2 8.5 0.6 10.3 7.2 8.7 0.6 10.3 6.8 145 0 145 165 1.6 0 1.6 1.4 02/17/2006 10:20:00 8.2 0.6 10.3 6.8 8.4 0.6 10.3 6.8 8.4 0.6 10.7 6.8 145 0 145 165 1.7 0 1.8 1.6 02/17/2006 10:30:00 10.1 0.9 12.2 8 10.2 0.8 12.2 8 10.2 0.9 11.8 8 145 0 145 165 1.8 0 1.8 1.6 02/17/2006 10:40:00 12.7 1.1 15.3 9.9 12.4 1.1 14.9 10.3 12.5 1 15.3 9.9 145 1 147 165 2.1 0 2.3 1.8 02/17/2006 10:50:00 12.9 0.7 14.5 10.3 12.8 0.7 14.5 10.7 12.9 0.7 14.5 10.3 148 4 150 165 2.5 0 2.8 2.3 02/17/2006 11:00:00 13.4 0.9 16.1 11.1 13.3 0.9 15.6 11.1 13.2 1 16.1 10.7 149 4 149 165 2.6 0 2.8 2.6 02/17/2006 11:10:00 12.6 1 14.9 10.7 12.6 0.9 15.3 10.7 12.5 1.1 14.5 8.8 147 4 148 165 2.7 0 2.8 2.6 02/17/2006 11:20:00 12.9 1 15.3 10.3 12.9 1 15.3 10.3 12.7 1.1 14.9 9.1 146 5 140 165 2.7 0 2.8 2.6 02/17/2006 11:30:00 14.2 0.7 15.6 11.8 14.1 0.7 15.6 11.8 13.9 0.8 15.6 10.7 146 3 148 165 2.7 0 2.8 2.6 02/17/2006 11:40:00 13.7 1 15.6 11.5 13.7 1 16.1 11.1 13.6 1 16.1 10.7 147 3 145 165 2.7 0 2.8 2.6 02/17/2006 11:50:00 13.6 1.1 16.4 11.1 13.6 1.1 16.4 11.1 13.3 1.3 16.1 9.1 147 5 150 165 2.8 0 2.8 2.8 02/17/2006 12:00:00 13.9 0.8 16.1 11.5 13.9 0.8 16.1 11.1 13.5 1 16.1 9.5 146 5 154 165 2.7 0 2.8 2.8 02/17/2006 12:10:00 14.9 0.8 17.2 13 14.9 0.8 16.8 12.6 14.5 1 16.8 11.5 148 4 145 165 2.7 0 2.8 2.8 02/17/2006 12:20:00 16 0.9 17.9 13.3 15.9 0.8 17.9 13.3 15.6 1.1 17.9 11.8 148 3 152 165 2.7 0 2.8 2.6 02/17/2006 12:30:00 16.2 0.8 17.9 14.1 16.1 0.8 17.9 14.1 15.9 1 18.3 11.8 148 4 144 165 2.6 0 2.8 2.6 02/17/2006 12:40:00 15.9 1 18.3 13 15.9 1 18.3 13 15.6 1.2 17.9 11.8 148 4 147 165 2.6 0 2.8 2.6 02/17/2006 12:50:00 16.3 1.1 18.3 11.8 16.2 1.1 18.3 11.5 16.1 1.3 18.7 12.2 147 3 148 165 2.6 0.1 2.8 2.6 02/17/2006 13:00:00 16.1 1 17.9 13.3 16.1 1 18.3 13 16 1 18.3 13 147 4 146 165 2.4 0 2.6 2.3 02/17/2006 13:10:00 15.7 1.1 17.9 12.6 15.7 1.1 17.9 12.6 15.7 1.1 18.3 11.8 148 4 143 165 2.4 0 2.6 2.3 02/17/2006 13:20:00 13.9 1.1 16.1 11.5 13.8 1.1 16.1 11.1 13.7 1.4 16.4 9.9 147 5 151 165 2.4 0 2.6 2.3 02/17/2006 13:30:00 13.8 0.7 15.6 11.8 13.8 0.7 15.6 11.8 13.8 0.8 15.6 10.7 147 5 146 165 2.5 0 2.6 2.6 02/17/2006 13:40:00 12.4 0.9 14.5 10.7 12.3 0.9 14.5 10.3 12.2 0.9 14.9 9.5 149 3 147 165 2.5 0 2.8 2.6 02/17/2006 13:50:00 10.7 1 12.6 7.6 10.6 0.9 12.6 7.6 10.4 1.1 12.6 6.8 148 6 154 165 2.7 0 2.8 2.6 02/17/2006 14:00:00 11.5 1.3 15.3 8.4 11.5 1.3 15.3 8.4 11.3 1.5 14.9 8 143 7 141 165 2.8 0 2.8 2.8 02/17/2006 14:10:00 13.6 1.1 16.1 9.9 13.6 1.1 16.1 9.5 13.3 1.3 16.4 9.9 146 5 149 165 2.7 0 2.8 2.6 02/17/2006 14:20:00 13 1.2 16.1 10.7 12.9 1.2 16.1 10.7 12.6 1.3 16.4 9.5 145 4 149 165 2.8 0 2.8 2.6 02/17/2006 14:30:00 13.4 1 15.3 10.7 13.4 1 15.3 11.1 13.2 1.2 15.3 10.3 146 5 150 165 2.6 0 2.8 2.6 02/17/2006 14:40:00 13.8 0.9 16.1 11.5 13.8 0.9 16.1 11.5 13.6 1 16.1 9.9 144 7 141 165 2.7 0 2.8 2.6 02/17/2006 14:50:00 14.1 1 16.8 11.1 14.1 1 16.8 11.1 13.9 1.1 16.4 11.1 147 4 147 165 2.7 0 2.8 2.6 02/17/2006 15:00:00 12.7 0.9 15.3 10.3 12.7 0.9 15.3 10.3 12.6 1 15.6 9.9 148 4 147 165 2.6 0 2.8 2.6 02/17/2006 15:10:00 12.8 0.9 14.5 10.3 12.7 0.9 14.1 9.9 12.5 1.2 14.5 8.4 148 5 160 165 2.4 0 2.6 2.3 02/17/2006 15:20:00 11.1 1 13.3 8.8 11 1 13 8.4 11 1 13.3 8 154 5 151 165 2.2 0 2.3 2.1 02/17/2006 15:30:00 11.4 1.2 13.7 8 11.4 1.2 14.1 8.4 11.3 1.3 13.3 7.6 146 5 150 165 2.4 0 2.6 2.3 02/17/2006 15:40:00 11.7 0.6 13.3 10.3 11.7 0.6 13.3 10.3 11.5 0.8 14.1 9.1 150 4 154 165 2.3 0 2.6 2.3 02/17/2006 15:50:00 12.3 0.6 14.1 10.7 12.3 0.6 14.1 10.7 12.5 0.7 14.1 9.5 153 3 148 165 2.3 0 2.3 2.1 02/17/2006 16:00:00 12.8 0.6 14.1 11.1 12.7 0.6 13.7 11.1 13 0.6 14.1 10.7 154 3 151 165 2.1 0 2.3 1.8 02/17/2006 16:10:00 12.5 0.6 14.1 10.7 12.5 0.6 14.1 10.7 12.6 0.6 14.1 10.7 151 3 152 165 2.1 0 2.3 1.8 02/17/2006 16:20:00 13.8 1.3 16.8 10.7 13.8 1.4 16.8 10.7 13.9 1.3 16.8 10.7 147 5 148 165 2.2 0 2.3 2.1 02/17/2006 16:30:00 15.1 0.7 17.6 12.2 15.1 0.7 17.2 12.2 15.1 0.9 17.2 11.8 149 3 144 165 2 0.1 2.3 1.8 02/17/2006 16:40:00 14.5 0.8 16.1 11.5 14.5 0.8 16.1 11.1 14.6 1 16.8 10.3 148 3 148 165 1.7 0 1.8 1.6 02/17/2006 16:50:00 13.2 0.5 14.5 11.5 13.1 0.5 14.1 11.1 13.2 0.7 14.5 10.3 147 3 148 165 1.7 0 1.8 1.6 02/17/2006 17:00:00 12.2 0.7 13.7 10.3 12.1 0.7 13.7 9.9 12.3 0.9 14.1 9.1 150 0 149 165 1.6 0 1.6 1.6 02/17/2006 17:10:00 11.8 0.5 13 9.9 11.7 0.5 12.6 9.9 11.8 0.8 13.3 8.4 150 0 150 165 1.5 0 1.8 1.4 02/17/2006 17:20:00 11.6 0.6 13.3 9.9 11.5 0.6 13 9.9 11.7 0.7 13.3 9.9 150 0 150 165 1.4 0 1.6 1.4 02/17/2006 17:30:00 10.8 0.5 11.8 9.5 10.8 0.4 11.8 9.5 11 0.7 12.6 9.1 150 0 150 165 1.3 0 1.4 1.1 02/17/2006 17:40:00 9.9 0.6 11.8 8.4 9.8 0.5 11.5 8.8 9.8 0.6 11.5 8 151 0 151 165 1.1 0 1.4 0.9 02/17/2006 17:50:00 9.5 0.5 10.7 8 9.5 0.5 10.7 8 9.6 0.5 10.7 7.6 151 0 151 165 1.1 0 1.4 0.9 02/17/2006 18:00:00 9 0.4 10.3 7.6 9.1 0.4 10.3 8 9.3 0.5 10.3 8 151 0 151 165 1 0 1.1 0.9 02/17/2006 18:10:00 8.2 0.4 9.1 7.2 8.2 0.4 9.1 7.2 8.2 0.6 9.9 6.8 151 0 151 165 1 0 1.1 0.9 02/17/2006 18:20:00 8.1 0.4 9.1 7.2 8.2 0.4 9.1 7.2 8.4 0.4 9.5 7.2 151 0 151 165 1 0 1.1 0.9 02/17/2006 18:30:00 7.7 0.5 9.1 6.5 7.7 0.5 8.8 6.5 7.9 0.5 9.1 6.8 151 0 151 165 1.1 0 1.1 0.9 02/17/2006 18:40:00 7.1 0.5 8.4 5.7 7 0.6 8.8 5.7 7.3 0.6 8.8 5.7 151 0 151 165 1.1 0 1.4 0.9 02/17/2006 18:50:00 6.5 0.5 8 4.9 6.3 0.5 8 4.6 6.4 0.6 7.6 4.6 151 0 151 165 1.1 0 1.4 1.1 02/17/2006 19:00:00 6.1 0.5 7.6 4.9 5.8 0.6 7.2 4.6 5.7 0.6 7.2 3.8 151 0 151 165 1.2 0 1.4 1.1 02/17/2006 19:10:00 5.8 0.6 7.2 4.2 5.6 0.6 6.8 3.8 5.3 0.6 8 3.8 151 0 151 165 1.2 0 1.4 1.1 02/17/2006 19:20:00 5.7 0.5 7.2 4.6 5.6 0.6 6.8 4.2 5.3 0.6 6.8 3.8 151 0 151 165 1.3 0 1.4 1.4 02/17/2006 19:30:00 5.1 0.6 6.8 3 4.9 0.5 6.5 3 4.9 0.7 6.5 2.6 151 0 151 165 1.3 0 1.4 1.4 02/17/2006 19:40:00 4.7 0.7 6.5 3 4.7 0.7 6.5 3 4.6 0.8 6.8 3 151 0 151 165 1.4 0 1.4 1.4 02/17/2006 19:50:00 5 0.6 6.8 3 4.9 0.6 6.5 3 4.8 0.6 6.5 2.6 151 0 151 165 1.4 0 1.4 1.4 02/17/2006 20:00:00 5.5 0.6 6.8 3.8 5.4 0.7 6.8 3.4 5 0.8 7.6 3.4 151 0 151 165 1.4 0 1.6 1.4 02/17/2006 20:10:00 5.6 0.6 7.2 3.8 5.6 0.7 7.2 3.4 6.1 0.8 8 4.2 151 0 151 165 1.4 0 1.6 1.4 02/17/2006 20:20:00 5.5 0.4 6.8 4.2 6 0.5 7.6 4.6 6.4 0.5 7.6 4.9 151 0 151 165 1.4 0 1.6 1.4 02/17/2006 20:30:00 5.5 0.3 6.5 4.6 6.1 0.4 6.8 4.9 6 0.4 6.8 4.9 151 0 151 165 1.4 0 1.6 1.4 02/17/2006 20:40:00 5 0.4 6.1 3.8 5.4 0.4 6.5 4.2 5.2 0.6 6.5 3.4 151 0 151 165 1.4 0 1.6 1.4 02/17/2006 20:50:00 4.4 0.4 5.7 3.4 5.1 0.3 6.1 4.2 4.7 0.6 6.1 3 151 0 151 165 1.4 0 1.6 1.4 02/17/2006 21:00:00 3.9 0.5 4.9 2.6 4.7 0.5 6.1 3.4 4.3 0.7 6.1 3 151 0 151 165 1.4 0 1.6 1.4 02/17/2006 21:10:00 4.1 0.6 5.3 2.3 4.9 0.6 6.1 3 4.6 0.8 6.5 2.6 151 0 151 165 1.4 0 1.6 1.4 02/17/2006 21:20:00 4.1 0.5 5.7 2.6 4.8 0.6 6.5 3 5.1 0.7 6.5 3 151 0 151 165 1.4 0 1.4 1.4 02/17/2006 21:30:00 3.6 0.4 4.9 2.6 4.2 0.5 5.7 3 4.8 0.4 6.1 3.8 151 0 151 165 1.4 0 1.4 1.4 02/17/2006 21:40:00 3.2 0.6 4.6 1.9 3.8 0.6 4.9 2.3 4.1 0.6 5.3 3 151 0 151 165 1.4 0 1.6 1.4 02/17/2006 21:50:00 3.2 0.6 4.6 1.5 4 0.7 5.3 1.9 3.9 0.6 5.7 2.3 151 0 151 165 1.4 0 1.6 1.4 02/17/2006 22:00:00 3.1 0.5 4.6 1.9 4.1 0.6 5.3 2.3 4.3 0.7 6.1 2.3 151 0 151 165 1.5 0 1.6 1.4 02/17/2006 22:10:00 2.7 0.4 3.8 1.1 4 0.4 4.9 2.6 4.2 0.7 5.7 2.3 151 0 151 165 1.5 0 1.6 1.4 02/17/2006 22:20:00 2.5 0.5 3.8 1.5 4.1 0.7 5.7 2.6 4.2 0.7 5.7 2.3 151 0 151 165 1.6 0 1.6 1.6 02/17/2006 22:30:00 2.6 0.5 3.8 1.5 3.8 0.6 4.9 2.6 4.2 0.5 5.7 3 151 0 151 165 1.5 0 1.6 1.4 02/17/2006 22:40:00 1.7 1 3.4 0.4 2.5 0.7 4.2 0.7 3.6 0.4 4.9 2.6 151 0 151 165 1.4 0 1.6 1.4 02/17/2006 22:50:00 0.4 0 0.4 0.4 0.9 1 3.8 0.4 1.7 1.5 4.6 0.4 151 0 165 165 1.4 0 1.4 1.4 02/17/2006 23:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 151 0 165 165 1.2 0 1.4 1.4 02/17/2006 23:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 151 0 165 165 1.2 0 1.4 1.4 02/17/2006 23:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 151 0 165 165 1.2 0 1.4 1.1 02/17/2006 23:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 151 0 165 165 1.2 0 1.4 1.1 02/17/2006 23:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 151 0 165 165 1.4 0 1.4 1.4 02/17/2006 23:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 151 0 165 165 1.4 0 1.6 1.4 02/18/2006 00:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 151 0 165 165 1.4 0 1.6 1.4 02/18/2006 00:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 151 0 165 165 1.5 0 1.6 1.4 02/18/2006 00:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 151 0 165 165 1.6 0 1.6 1.6 02/18/2006 00:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 151 0 165 165 1.6 0 1.6 1.6 02/18/2006 00:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 151 0 165 165 1.7 0 1.8 1.6 02/18/2006 00:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 151 0 165 165 1.7 0 1.8 1.6 02/18/2006 01:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 151 0 165 165 1.7 0 1.6 1.6 02/18/2006 01:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 151 0 165 165 1.7 0 1.8 1.6 02/18/2006 01:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 151 0 165 165 1.7 0 1.8 1.6 02/18/2006 01:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 151 0 165 165 1.7 0 1.8 1.6 02/18/2006 01:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 151 0 165 165 1.7 0 1.8 1.6 02/18/2006 01:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 151 0 165 165 1.7 0 1.8 1.6 02/18/2006 02:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 151 0 165 165 1.7 0 1.8 1.6 02/18/2006 02:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 151 0 165 165 1.7 0 1.8 1.6 02/18/2006 02:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 151 0 165 165 1.7 0 1.8 1.6 02/18/2006 02:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 151 0 165 165 1.7 0 1.8 1.6 02/18/2006 02:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 151 0 165 165 1.7 0 1.8 1.6 02/18/2006 02:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 151 0 165 165 1.7 0 1.8 1.6 02/18/2006 03:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 151 0 165 165 1.7 0 1.8 1.6 02/18/2006 03:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 150 0 165 165 1.7 0 1.8 1.6 02/18/2006 03:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 150 0 165 165 1.7 0 1.8 1.6 02/18/2006 03:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 151 0 165 165 1.7 0 1.8 1.6 02/18/2006 03:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 151 0 165 165 1.7 0 1.8 1.6 02/18/2006 03:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 151 0 165 165 1.7 0 1.8 1.6 02/18/2006 04:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 1.1 0.4 151 0 165 165 1.8 0 1.8 1.6 02/18/2006 04:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 150 0 165 165 1.8 0 1.8 1.6 02/18/2006 04:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 150 0 165 165 1.8 0 1.8 1.6 02/18/2006 04:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 150 0 165 165 1.7 0 1.8 1.6 02/18/2006 04:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 150 0 165 165 1.8 0 1.8 1.6 02/18/2006 04:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 150 0 165 165 1.8 0 1.8 1.6 02/18/2006 05:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 150 0 165 165 1.8 0 1.8 1.6 02/18/2006 05:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 150 0 165 165 1.8 0 1.8 1.8 02/18/2006 05:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 150 0 165 165 1.8 0 1.8 1.8 02/18/2006 05:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 150 0 165 165 1.8 0 1.8 1.6 02/18/2006 05:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 150 0 165 165 1.8 0 1.8 1.6 02/18/2006 05:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 150 0 165 165 1.8 0 1.8 1.8 02/18/2006 06:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 150 0 165 165 1.8 0 1.8 1.6 02/18/2006 06:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 151 0 165 165 1.8 0 1.8 1.6 02/18/2006 06:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 151 0 165 165 1.8 0 1.8 1.6 02/18/2006 06:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 151 0 165 165 1.7 0 1.8 1.6 02/18/2006 06:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 151 0 165 165 1.9 0 2.1 1.8 02/18/2006 06:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 151 0 165 165 2 0 2.3 1.8 02/18/2006 07:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 151 0 165 165 2.1 0 2.3 1.8 02/18/2006 07:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 151 0 165 165 2.1 0.1 2.3 1.8 02/18/2006 07:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 151 0 165 165 1.9 0 2.1 1.8 02/18/2006 07:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 151 0 165 165 1.7 0 1.8 1.4 02/18/2006 07:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 151 0 165 165 1.4 0 1.6 1.4 02/18/2006 07:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 151 0 165 165 1.4 0 1.6 1.4 02/18/2006 08:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 151 0 165 165 1.4 0 1.6 1.4 02/18/2006 08:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 151 0 165 165 1.4 0 1.6 1.4 02/18/2006 08:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 151 0 165 165 1.5 0 1.6 1.4 02/18/2006 08:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 151 0 165 165 1.6 0 1.8 1.4 02/18/2006 08:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 151 0 165 165 1.7 0 1.8 1.6 02/18/2006 08:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 151 0 165 165 1.7 0 1.8 1.6 02/18/2006 09:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 151 0 165 165 1.8 0 1.8 1.8 02/18/2006 09:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 151 0 165 165 2.1 0.1 2.6 1.8 02/18/2006 09:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 150 0 165 165 2.6 0.1 2.8 2.3 02/18/2006 09:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 150 0 165 165 3.2 0.2 3.5 2.8 02/18/2006 09:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 148 1 165 165 3.6 0 3.8 3.5 02/18/2006 09:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.5 0.2 1.1 0.4 154 4 165 165 3.5 0.1 3.5 3.3 02/18/2006 10:00:00 0.5 0.2 1.1 0.4 0.5 0.2 1.1 0.4 0.8 0.2 1.5 0.4 162 5 164 165 2.9 0.1 3.3 2.6 02/18/2006 10:10:00 0.6 0.2 1.1 0.4 0.5 0.2 1.1 0.4 0.6 0.3 1.1 0.4 155 7 164 165 2.4 0 2.8 2.3 02/18/2006 10:20:00 0.7 0.3 1.5 0.4 0.7 0.4 1.5 0.4 0.5 0.3 1.5 0.4 156 7 159 165 2.8 0.1 3.3 2.6 02/18/2006 10:30:00 0.4 0.2 1.1 0.4 0.4 0.2 1.1 0.4 0.4 0.1 1.1 0.4 167 9 174 165 3 0 3.3 2.8 02/18/2006 10:40:00 0.6 0.4 1.9 0.4 0.5 0.3 1.5 0.4 0.4 0.2 1.1 0.4 183 9 178 165 3 0 3.3 2.8 02/18/2006 10:50:00 0.5 0.3 1.5 0.4 0.6 0.4 1.9 0.4 0.5 0.4 2.3 0.4 174 15 164 165 3.4 0.2 3.5 2.8 02/18/2006 11:00:00 2.3 1.3 4.6 0.4 2.7 0.7 4.2 0.4 2.1 0.6 3.8 0.4 166 11 163 165 3.5 0 3.5 3.3 02/18/2006 11:10:00 3.5 0.8 5.7 1.9 3.4 0.7 5.3 1.9 3.3 0.8 5.3 1.5 166 10 171 165 3 0.3 3.5 2.3 02/18/2006 11:20:00 4.5 0.9 6.8 2.3 4.3 0.9 6.5 2.3 4.3 0.8 6.8 2.3 177 8 179 165 2.1 0 2.6 1.8 02/18/2006 11:30:00 5.3 0.9 7.6 3 5.1 0.8 7.2 3 5.1 0.7 6.8 3.4 173 13 179 165 2.1 0 2.6 1.8 02/18/2006 11:40:00 4.8 0.6 6.5 3 4.6 0.6 6.1 2.6 4.8 0.6 6.5 3.4 160 6 158 165 2.6 0.3 3.3 2.3 02/18/2006 11:50:00 5.6 0.5 7.2 4.6 5.4 0.5 7.2 4.6 5.8 0.5 7.6 4.9 158 5 159 165 2.6 0.2 3.3 2.3 02/18/2006 12:00:00 5.9 0.6 7.6 3.8 5.7 0.6 7.6 3.8 5.9 0.6 7.6 3 179 13 187 165 2.6 0 2.8 2.3 02/18/2006 12:10:00 6.4 0.9 8.8 4.2 6.3 0.8 8.8 4.2 6.6 0.9 9.5 4.6 188 11 179 165 3 0.1 3.3 2.6 02/18/2006 12:20:00 7.1 1 9.1 4.6 7 1 8.8 4.9 7.6 1 9.9 4.9 180 10 180 165 3 0 3.3 2.8 02/18/2006 12:30:00 6.8 0.8 8.8 4.9 6.7 0.8 8.4 4.9 7 0.8 9.9 4.9 187 7 186 165 3.4 0.1 3.5 3.3 02/18/2006 12:40:00 6.9 1.1 11.1 4.6 6.8 1.1 11.1 4.6 7.2 1.1 11.5 4.9 184 10 203 165 3.1 0.2 3.5 2.8 02/18/2006 12:50:00 9.2 0.7 11.1 6.5 9.3 0.8 10.7 6.5 9.5 0.9 11.8 6.5 192 5 201 165 2.9 0 3 2.8 02/18/2006 13:00:00 9 1 11.5 6.1 9.1 1 11.5 6.5 9.3 1.1 11.8 6.8 193 6 191 165 2.9 0 3 2.8 02/18/2006 13:10:00 7.9 1 10.7 5.3 7.7 1 10.7 5.3 8.2 1 11.1 5.3 182 9 200 165 2.9 0 3 2.8 02/18/2006 13:20:00 8.6 1 11.1 6.5 8.4 1 10.7 6.1 8.9 0.9 11.5 6.1 180 8 184 165 2.9 0 3 2.8 02/18/2006 13:30:00 8.2 1 10.7 5.3 8.2 1 11.1 5.3 8.3 1.1 11.5 5.7 185 10 178 165 2.8 0 2.8 2.8 02/18/2006 13:40:00 8.1 1.1 10.7 5.3 7.9 1.1 10.7 4.6 8.2 1.1 11.1 5.7 184 12 198 165 2.8 0 2.8 2.6 02/18/2006 13:50:00 6.3 1.1 8.4 3.8 6.3 1.1 8.4 3.4 6.5 1 8.8 4.6 182 10 189 165 2.7 0 2.8 2.6 02/18/2006 14:00:00 8 1.1 10.3 4.6 8 1.1 10.3 4.6 8 1.2 10.3 5.3 193 8 199 165 2.7 0 2.8 2.6 02/18/2006 14:10:00 8 0.8 9.9 5.7 8.1 0.8 9.9 5.7 8 0.9 9.9 5.3 200 6 196 165 2.5 0 2.8 2.6 02/18/2006 14:20:00 9.2 0.8 12.2 7.6 9.2 0.7 11.8 7.6 9.3 0.8 11.8 7.2 195 5 192 165 2.6 0 2.8 2.6 02/18/2006 14:30:00 9.5 0.9 11.8 6.8 9.4 0.9 11.5 7.2 9.5 1 11.8 6.8 189 6 184 165 2.7 0 2.8 2.6 02/18/2006 14:40:00 9.9 1 12.2 7.2 9.7 1 11.8 7.2 10.1 1.1 12.6 6.8 186 7 180 165 2.8 0 2.8 2.6 02/18/2006 14:50:00 10.1 0.9 12.6 7.6 9.9 0.8 12.2 7.2 10.2 0.9 12.6 8 184 6 192 165 2.9 0 3 2.8 02/18/2006 15:00:00 9.9 1 12.2 6.5 9.6 1 11.8 6.8 10 1 13 7.2 182 7 181 165 2.9 0 3 2.8 02/18/2006 15:10:00 9.9 0.9 13 7.6 9.8 0.9 12.6 7.6 10.1 1 12.6 8 184 8 187 165 2.9 0 3 2.8 02/18/2006 15:20:00 10.3 1.2 13.3 7.6 10.1 1.2 13.3 8 10.4 1.1 13.7 7.2 182 9 188 165 2.9 0 3 2.8 02/18/2006 15:30:00 10.2 1.1 13 7.6 10.1 1 12.6 7.6 10.5 1 13 8 185 9 191 165 3 0 3 2.8 02/18/2006 15:40:00 10 1.2 13.3 6.5 9.9 1.2 13 6.1 10.2 1.2 13.7 7.6 186 8 186 165 3 0 3 2.8 02/18/2006 15:50:00 11 1.2 13.7 8 11 1.2 13.3 8 11.1 1.4 14.5 8.4 187 8 192 165 3 0 3 2.8 02/18/2006 16:00:00 10.9 1.2 14.1 8.4 10.8 1.2 14.5 8 11 1.1 13.7 8.4 187 7 197 165 3 0 3 2.8 02/18/2006 16:10:00 11 0.9 13.7 8 11 0.9 13.7 8 11.1 1 13.3 7.6 193 6 190 165 3 0 3.3 2.8 02/18/2006 16:20:00 9.7 0.6 11.8 8 9.4 0.7 11.8 7.6 10 0.8 13 7.6 179 8 194 165 2.8 0 3 2.6 02/18/2006 16:30:00 10.1 1 12.6 7.6 9.8 0.8 11.5 7.6 10.2 1 12.6 7.6 176 7 176 165 2.6 0.1 2.8 2.3 02/18/2006 16:40:00 10.5 0.9 13.3 8.4 10.2 0.9 12.6 8 10.7 0.9 13.3 8.4 180 6 189 165 2.5 0 2.6 2.3 02/18/2006 16:50:00 9.7 0.8 11.8 7.6 9.3 0.8 11.1 7.6 9.8 0.8 11.8 7.2 177 6 185 165 2.4 0 2.6 2.3 02/18/2006 17:00:00 8.9 1.2 11.5 6.1 8.6 1.1 11.1 6.1 9.1 1.1 11.8 6.5 176 6 178 165 2.4 0 2.6 2.3 02/18/2006 17:10:00 9.1 0.9 11.1 6.5 8.9 0.8 10.7 6.5 9.2 1 11.8 6.8 176 8 175 165 2.3 0 2.6 2.3 02/18/2006 17:20:00 8.8 1.1 11.5 6.5 8.6 1 10.7 6.1 8.9 1.1 11.5 6.5 175 9 167 165 2.3 0 2.6 2.3 02/18/2006 17:30:00 10 0.8 11.8 8 9.6 0.7 11.5 8 10 0.8 12.2 7.6 174 6 176 165 2.2 0 2.3 2.1 02/18/2006 17:40:00 10.5 0.8 12.2 8 10.2 0.8 11.8 8 10.6 0.9 12.6 8 174 13 172 165 2.3 0 2.3 2.3 02/18/2006 17:50:00 9.4 0.9 11.8 7.2 9.1 0.8 11.1 7.2 9.5 1 12.6 7.6 172 7 187 165 2.3 0 2.3 2.1 02/18/2006 18:00:00 9.2 1.1 11.5 6.1 8.8 1 11.1 6.1 9.2 1.1 11.5 6.1 173 6 180 165 2.3 0 2.6 2.3 02/18/2006 18:10:00 9.2 1 11.5 6.5 8.9 0.9 11.1 6.1 9.3 1 11.1 6.5 174 6 165 165 2.2 0 2.3 2.1 02/18/2006 18:20:00 9.1 0.9 11.1 7.2 8.7 0.8 10.7 6.8 9.1 1 11.5 7.2 174 6 176 165 2.2 0 2.3 2.1 02/18/2006 18:30:00 7.9 0.8 9.9 5.3 7.5 0.8 9.5 5.3 7.8 0.9 9.9 5.3 171 7 170 165 2.2 0 2.3 2.1 02/18/2006 18:40:00 6.7 0.6 8.4 5.3 6.5 0.6 8 5.3 6.8 0.7 8.8 5.7 170 8 162 165 2.1 0 2.3 1.8 02/18/2006 18:50:00 8.4 0.6 9.9 6.1 8.1 0.6 9.5 6.1 8.4 0.5 9.5 6.5 170 9 165 165 2.1 0 2.3 1.8 02/18/2006 19:00:00 8.3 0.6 9.9 6.8 8 0.6 9.5 6.5 8.4 0.6 9.9 6.8 169 7 173 165 2.1 0 2.3 2.1 02/18/2006 19:10:00 9.5 1.6 12.6 5.7 9.2 1.5 12.2 5.3 9.6 1.5 12.6 5.7 174 7 184 165 2.3 0 2.6 2.3 02/18/2006 19:20:00 12 1.2 14.5 8.4 11.7 1.1 13.7 8 11.8 1.3 14.1 9.1 181 5 178 165 2.7 0 2.8 2.6 02/18/2006 19:30:00 11.9 1 14.5 9.5 11.5 1 13.7 8.8 11.9 1 13.7 9.5 176 6 176 165 2.8 0 2.8 2.6 02/18/2006 19:40:00 10.8 1 13 8.4 10.5 0.9 12.6 8.4 11 1 13.3 8 168 8 164 165 2.5 0 2.8 2.3 02/18/2006 19:50:00 11 0.8 12.6 7.6 10.6 0.8 11.8 7.2 11.2 0.9 12.6 7.6 167 8 165 165 2.6 0.1 2.8 2.6 02/18/2006 20:00:00 10.6 0.6 11.8 7.6 10.2 0.6 11.8 7.6 10.8 0.6 12.6 8.4 169 6 189 165 2.5 0 2.8 2.3 02/18/2006 20:10:00 10.8 0.6 12.6 9.5 10.3 0.6 12.2 9.1 10.9 0.7 13 9.5 172 6 165 165 2.6 0.1 2.8 2.6 02/18/2006 20:20:00 10.4 0.5 11.5 8.8 10 0.5 11.1 8.4 10.4 0.6 11.8 9.1 176 4 165 165 2.6 0 2.8 2.3 02/18/2006 20:30:00 10 1 12.6 7.2 9.8 1 11.8 7.2 10.1 1 12.2 7.2 182 5 181 165 3 0.1 3.3 2.6 02/18/2006 20:40:00 7.6 0.9 9.9 4.9 7.5 0.9 9.9 4.6 7.7 0.9 9.9 5.3 183 7 192 165 3 0 3.3 2.8 02/18/2006 20:50:00 6.5 1.1 9.9 3.4 6.4 1.1 9.5 3.8 6.6 1.1 9.1 3.4 193 8 204 165 3.2 0 3.5 2.8 02/18/2006 21:00:00 5.9 0.8 8 3.8 5.8 0.8 8 3.8 6 0.8 7.6 4.2 191 9 193 165 3.2 0 3.5 3 02/18/2006 21:10:00 6.9 0.9 8.8 4.9 6.7 0.8 8.4 4.9 6.6 0.8 9.5 4.6 180 8 189 165 3.2 0 3.3 3 02/18/2006 21:20:00 6.3 1 8.8 4.2 6.2 1 8.8 3.8 6.2 1 8.4 4.2 183 9 177 165 3.2 0 3.5 3 02/18/2006 21:30:00 6.2 1 8.4 3.4 6.1 1 8.4 3.8 6.1 0.9 8.4 4.2 186 11 187 165 3.3 0 3.5 3.3 02/18/2006 21:40:00 6.8 0.9 9.5 4.9 6.6 0.8 9.1 4.6 6.8 0.8 9.1 4.6 180 9 173 165 3.4 0 3.5 3.3 02/18/2006 21:50:00 6.9 1.1 9.1 3.4 6.7 1 9.1 3.8 6.8 1 8.8 3.4 185 9 194 165 3.5 0 3.5 3.3 02/18/2006 22:00:00 6.7 0.7 8.4 4.2 6.6 0.7 8.4 4.2 6.7 0.7 8.8 4.6 189 6 186 165 3.5 0 3.5 3.5 02/18/2006 22:10:00 5.6 0.5 6.8 4.2 5.5 0.5 6.8 4.2 5.6 0.5 6.8 4.2 182 5 188 165 3.5 0 3.5 3.5 02/18/2006 22:20:00 3.5 0.8 5.7 0.7 3.4 0.8 5.3 1.1 3.4 0.8 5.3 1.9 168 11 171 165 3.3 0 3.5 3.3 02/18/2006 22:30:00 2.6 0.5 4.2 1.1 2.6 0.6 4.2 1.1 2.5 0.6 4.2 1.1 190 11 192 165 3.7 0 3.8 3.3 02/18/2006 22:40:00 2.4 0.8 3.4 0.4 2.3 0.7 3.8 0.4 2.4 0.6 3.4 0.4 156 22 197 165 3.6 0.2 4 3.3 02/18/2006 22:50:00 1.8 0.6 3.8 0.4 1.7 0.6 3.4 0.4 1.4 0.6 3 0.4 199 13 171 165 3.6 0 3.8 3.3 02/18/2006 23:00:00 1.4 0.7 3.4 0.4 1.4 0.7 3.4 0.4 1.4 0.8 3 0.4 147 43 102 165 3.5 0.2 4 3 02/18/2006 23:10:00 0.7 0.6 2.3 0.4 0.7 0.6 2.3 0.4 0.6 0.4 1.9 0.4 297 79 286 165 3.3 0.2 3.5 3 02/18/2006 23:20:00 1.6 0.4 2.3 0.7 1.7 0.3 2.3 0.7 0.9 0.3 1.9 0.4 297 7 298 165 3.8 0 4 3.5 02/18/2006 23:30:00 1.1 0.5 2.3 0.4 1.2 0.5 2.3 0.4 0.7 0.4 1.5 0.4 288 7 294 165 4.1 0 4.5 3.8 02/18/2006 23:40:00 1.8 0.3 2.3 1.1 2 0.3 2.6 1.1 1.3 0.5 2.3 0.4 288 6 287 165 4 0 4.3 3.8 02/18/2006 23:50:00 1.2 0.4 2.3 0.4 1.5 0.3 2.3 0.7 1.2 0.3 2.3 0.4 263 10 255 165 4 0.1 4.3 3.8 02/19/2006 00:00:00 1.9 0.5 2.6 0.4 2 0.4 3 0.7 1.9 0.6 3 0.4 238 17 247 165 4.4 0.2 4.8 4.3 02/19/2006 00:10:00 1.3 0.4 2.3 0.4 1.3 0.4 2.3 0.4 1.4 0.5 2.3 0.4 226 9 215 165 4.6 0 4.8 4.5 02/19/2006 00:20:00 0.9 0.5 1.9 0.4 0.8 0.5 2.3 0.4 0.8 0.5 1.9 0.4 294 29 298 165 4.6 0 4.8 4.5 02/19/2006 00:30:00 0.5 0.3 1.5 0.4 0.5 0.3 1.5 0.4 0.5 0.3 1.5 0.4 302 33 253 165 4.3 0 4.5 4.3 02/19/2006 00:40:00 1 0.5 1.9 0.4 0.8 0.5 1.9 0.4 1.1 0.5 1.9 0.4 328 18 328 165 4.3 0 4.5 4.3 02/19/2006 00:50:00 0.8 0.5 1.9 0.4 0.8 0.5 1.9 0.4 1 0.5 1.9 0.4 340 14 328 165 4.2 0 4.5 4.3 02/19/2006 01:00:00 0.4 0.2 2.3 0.4 0.4 0.1 1.5 0.4 0.4 0.1 1.1 0.4 316 64 258 165 4.6 0.2 5 4.3 02/19/2006 01:10:00 1.9 1.1 4.6 0.4 1.9 1.2 4.9 0.4 1.3 0.9 3.8 0.4 301 24 319 165 5.2 0.1 5.5 5 02/19/2006 01:20:00 2.2 1.1 5.7 0.4 2.4 1 6.1 0.4 1.7 1 4.9 0.4 280 16 297 165 5.2 0 5.5 5 02/19/2006 01:30:00 2.9 0.9 4.9 0.7 3.1 0.8 4.6 0.7 2 1 4.2 0.4 284 15 279 165 5.1 0.1 5.2 5 02/19/2006 01:40:00 4.3 1.7 6.5 0.4 4.3 1.7 6.8 0.4 3.2 1.9 6.5 0.4 280 24 292 165 5.3 0.1 5.7 5 02/19/2006 01:50:00 4.8 1.2 7.6 1.9 5.2 1 7.6 2.6 4.9 0.9 6.8 2.3 277 11 302 165 5.8 0 6 5.5 02/19/2006 02:00:00 3.5 1.2 7.2 0.4 4.2 1.3 7.6 0.7 3.6 1.3 6.8 0.4 252 18 242 165 5.8 0 6 5.7 02/19/2006 02:10:00 2.6 1 5.3 0.4 3.1 1.1 5.7 0.4 2.2 1.2 4.9 0.4 254 28 270 165 5.7 0.1 6 5.5 02/19/2006 02:20:00 1.9 1.3 5.3 0.4 2.2 1.4 5.7 0.4 1.5 1.1 4.6 0.4 238 49 247 165 5.7 0 6 5.7 02/19/2006 02:30:00 1.4 0.8 3.4 0.4 1.5 0.9 4.2 0.4 1.2 0.8 3.4 0.4 185 47 261 165 5.3 0.3 5.7 4.8 02/19/2006 02:40:00 1 0.9 4.2 0.4 1.1 1 4.6 0.4 0.9 0.7 3.8 0.4 220 61 283 165 4.5 0 4.8 4.3 02/19/2006 02:50:00 1.6 0.6 3.4 0.4 1.7 0.7 3.4 0.4 1.1 0.7 2.6 0.4 321 21 302 165 4.4 0.3 4.8 3.8 02/19/2006 03:00:00 1.1 0.6 2.6 0.4 1.1 0.6 3 0.4 1.1 0.6 2.6 0.4 181 61 316 165 3.3 0.2 3.8 2.8 02/19/2006 03:10:00 1.4 1.3 5.7 0.4 1.6 1.5 5.7 0.4 1.2 1.2 4.9 0.4 205 64 284 165 3.6 0.6 4.5 2.8 02/19/2006 03:20:00 1.5 1.1 4.6 0.4 1.8 1.2 4.6 0.4 1.1 0.8 4.2 0.4 219 49 241 165 4.1 0 4.5 4 02/19/2006 03:30:00 3.5 1.5 6.5 0.4 3.7 1.3 6.8 0.7 2.8 1.2 5.7 0.4 278 20 301 165 4.8 0.4 5.5 4.3 02/19/2006 03:40:00 5.3 0.8 7.2 2.6 5.2 0.8 6.8 2.6 4.1 0.7 6.1 1.9 296 9 304 165 5.4 0.1 5.5 5 02/19/2006 03:50:00 6.7 1 9.1 4.2 6.7 1 9.5 4.6 5 1.1 8.4 2.6 300 7 300 165 5.5 0.3 6 5 02/19/2006 04:00:00 6.8 1.3 8.8 3 6.7 1.3 9.1 3.4 5.2 1.3 8 2.6 304 5 308 165 5.9 0.1 6 5.7 02/19/2006 04:10:00 6.1 0.9 8 3.4 6.1 0.8 8 3.8 4.7 0.8 6.8 2.6 295 5 302 165 5.8 0 6 5.7 02/19/2006 04:20:00 5.6 0.8 8 3.8 5.7 0.8 8.4 3.8 4.8 0.8 6.5 3 289 7 300 165 5.7 0 6 5.5 02/19/2006 04:30:00 5.1 0.8 6.8 2.6 5.2 0.7 6.8 3 4.5 0.9 6.8 1.9 284 9 274 165 5.5 0 5.7 5.2 02/19/2006 04:40:00 4 1 6.8 2.3 4.7 0.7 6.8 2.6 4.3 0.6 5.7 1.9 259 12 279 165 4.6 0.3 5.5 4.3 02/19/2006 04:50:00 3.8 0.7 5.7 1.9 4.2 0.5 6.1 2.6 4.1 0.5 5.7 2.6 244 15 277 165 5 0 5.2 4.8 02/19/2006 05:00:00 3.1 0.5 4.6 1.5 3.2 0.6 5.7 1.5 3.1 0.5 4.9 1.5 244 11 266 165 5.4 0 5.7 5 02/19/2006 05:10:00 2.8 0.7 4.6 1.1 3.1 0.7 5.3 1.1 3.2 0.6 4.9 1.9 244 13 273 165 5.8 0 6 5.5 02/19/2006 05:20:00 4.3 1.3 6.8 1.5 4.7 1.2 6.8 1.5 4.3 1.4 6.8 1.1 275 11 277 165 5.7 0 5.7 5.7 02/19/2006 05:30:00 3.6 0.8 6.1 1.9 4 0.8 6.5 2.3 3.7 0.8 6.1 1.9 277 16 289 165 5.6 0.1 6 5.5 02/19/2006 05:40:00 3.5 1 6.1 1.5 3.7 0.9 6.1 1.9 3.3 0.7 4.9 1.5 289 10 298 165 6.1 0.2 6.5 5.7 02/19/2006 05:50:00 2.6 0.8 4.6 0.7 2.9 0.6 4.6 1.5 2.7 0.7 4.6 1.1 277 9 279 165 6.1 0.2 6.5 5.7 02/19/2006 06:00:00 4 0.6 5.7 1.9 4.1 0.6 6.1 1.9 4 0.6 5.7 1.9 282 7 280 165 5.8 0.1 6 5.7 02/19/2006 06:10:00 3.9 0.8 5.7 2.3 4.8 0.6 6.1 3.4 4.5 0.6 6.5 3 264 10 281 165 5.6 0 5.7 5.5 02/19/2006 06:20:00 3.8 0.9 6.5 1.5 4.8 0.7 7.2 3 4.6 0.7 6.8 3 264 9 269 165 5.6 0 5.7 5.5 02/19/2006 06:30:00 5.3 0.7 6.5 2.6 5.6 0.5 6.5 4.2 5.4 0.6 6.5 3.4 280 7 278 165 5.4 0 5.7 5.2 02/19/2006 06:40:00 6.5 0.6 8 5.3 6.6 0.6 8 4.9 5.3 0.8 7.6 3.4 293 6 292 165 5.6 0.3 6.2 5.2 02/19/2006 06:50:00 6.8 0.9 8.4 4.6 6.9 0.9 8.4 4.6 5.1 0.9 8 3 299 5 300 165 5.9 0.1 6.2 5.7 02/19/2006 07:00:00 6.3 0.8 8.8 4.2 6.3 0.8 8.8 4.2 5.7 1 8.4 3 310 7 313 165 6.2 0 6.2 6 02/19/2006 07:10:00 6.2 0.5 7.6 4.9 6.2 0.5 7.6 4.9 4.7 0.7 7.2 3.4 298 5 299 165 6.1 0 6.2 5.7 02/19/2006 07:20:00 6.7 0.6 8 4.9 6.7 0.6 8 4.9 6 1 8.4 3.8 295 5 293 165 5.6 0.2 6 5.2 02/19/2006 07:30:00 7 0.5 8.4 5.7 7.1 0.5 8.4 5.7 6.4 0.9 8.4 4.2 293 5 297 165 5.2 0 5.5 5 02/19/2006 07:40:00 6.9 0.4 8 5.7 6.9 0.4 8 5.7 5.3 0.8 7.2 3.4 303 5 297 165 5.3 0 5.5 5.2 02/19/2006 07:50:00 7 0.5 8.8 5.7 7 0.5 9.1 5.7 5.8 0.8 7.6 4.2 306 5 302 165 5.2 0 5.5 5 02/19/2006 08:00:00 6.4 0.5 7.6 4.6 6.4 0.5 7.6 4.6 5.5 0.6 6.8 3.8 308 4 306 165 5.2 0 5.5 5.2 02/19/2006 08:10:00 5.9 0.5 6.8 4.6 5.9 0.5 6.8 4.6 4.9 0.5 6.8 3.8 306 5 300 165 5.2 0 5.2 5 02/19/2006 08:20:00 5.6 0.4 6.5 4.6 5.6 0.4 6.5 4.9 4.4 0.5 5.3 3.4 304 3 292 165 5.1 0 5.2 5 02/19/2006 08:30:00 5.3 0.4 6.5 4.6 5.3 0.4 6.1 4.6 4.3 0.5 5.7 3 305 4 305 165 4.9 0 5 4.8 02/19/2006 08:40:00 5.1 0.4 5.7 4.2 5.1 0.3 5.7 4.2 3.9 0.5 5.3 3 301 5 303 165 4.9 0 5 4.8 02/19/2006 08:50:00 4.5 0.6 6.1 3 4.6 0.6 6.5 3 3.4 0.6 5.3 1.9 296 5 300 165 5.1 0 5.2 5 02/19/2006 09:00:00 4.2 0.4 4.9 3 4.3 0.5 5.3 3 3 0.4 4.2 1.9 295 4 289 165 5.2 0 5.2 5 02/19/2006 09:10:00 3.5 0.4 4.2 2.6 3.6 0.4 4.2 2.6 3 0.7 4.2 1.9 284 9 301 165 5.4 0 5.5 5 02/19/2006 09:20:00 3.5 0.4 4.2 2.6 3.7 0.3 4.2 3 3.8 0.3 4.6 3 271 4 270 165 5.6 0 5.7 5.5 02/19/2006 09:30:00 3.6 0.4 4.6 2.6 3.7 0.4 4.2 2.6 3.5 0.4 4.6 2.3 289 6 296 165 5.7 0 5.7 5.5 02/19/2006 09:40:00 3.6 0.5 5.3 2.3 3.6 0.5 4.6 2.3 3 0.5 4.2 1.9 305 5 290 165 5.6 0 5.7 5.5 02/19/2006 09:50:00 3.4 0.4 4.6 2.6 3.4 0.4 4.2 2.6 3.1 0.5 4.2 2.3 309 5 304 165 5.7 0 6 5.5 02/19/2006 10:00:00 3.7 0.4 4.6 2.6 3.7 0.4 4.6 2.6 3.5 0.4 4.6 2.6 313 4 307 165 5.6 0 5.7 5.5 02/19/2006 10:10:00 3.4 0.5 4.6 2.3 3.4 0.5 4.6 2.3 3 0.5 4.2 1.5 307 5 303 165 5.4 0 5.7 5.2 02/19/2006 10:20:00 3.4 0.4 4.2 2.6 3.3 0.3 4.2 2.3 2.7 0.4 3.8 1.9 298 5 294 165 5.2 0 5.5 5.2 02/19/2006 10:30:00 3.8 0.6 4.9 2.6 3.8 0.6 4.9 2.6 3.2 0.6 4.6 1.9 297 9 292 165 5.2 0 5.5 5 02/19/2006 10:40:00 4.3 0.5 5.7 2.6 4.4 0.5 5.7 3 3.9 0.7 5.3 2.3 283 7 282 165 5.2 0 5.5 5 02/19/2006 10:50:00 3.1 0.8 6.1 1.5 4.1 0.6 6.1 3.4 3.9 0.5 6.1 3 269 7 254 165 5.4 0.2 6 5.2 02/19/2006 11:00:00 3.6 0.8 5.7 2.3 3.8 0.8 5.7 2.3 3.4 1 5.3 1.9 287 16 247 165 5.6 0.2 6 5.2 02/19/2006 11:10:00 3.7 1 6.5 1.1 3.8 1 6.8 1.5 3.3 0.9 6.1 1.9 288 15 273 165 5.4 0 5.7 5.2 02/19/2006 11:20:00 2.8 0.6 4.6 1.1 3.1 0.6 4.6 1.5 2.9 0.6 4.9 1.1 288 15 281 165 5.8 0.1 6.2 5.5 02/19/2006 11:30:00 2.7 0.6 4.2 1.1 3 0.5 4.2 1.1 2.9 0.6 4.2 1.1 282 15 295 165 5.9 0.1 6.2 5.5 02/19/2006 11:40:00 3.6 0.9 5.7 1.5 4.3 0.5 5.7 3 4.2 0.5 5.7 2.6 270 8 284 165 6.1 0.2 6.2 5.5 02/19/2006 11:50:00 3.4 0.8 4.9 1.1 3.7 0.7 4.9 1.1 3.6 0.7 5.3 1.5 276 9 281 165 5.9 0 6 5.5 02/19/2006 12:00:00 3.2 0.7 4.6 1.5 3.4 0.6 4.6 1.5 2.9 0.7 4.2 0.7 287 6 286 165 5.9 0.1 6.2 5.7 02/19/2006 12:10:00 4.2 0.7 5.3 1.9 4.3 0.7 5.7 2.3 3.4 0.6 4.9 1.5 294 5 299 165 6 0.1 6.2 5.7 02/19/2006 12:20:00 4 0.8 5.3 1.9 4.1 0.7 5.7 2.3 3.3 0.5 5.3 1.9 292 9 289 165 5.9 0.1 6.2 5.5 02/19/2006 12:30:00 3.3 0.9 5.3 1.5 3.4 0.8 5.3 1.9 3.2 0.7 4.9 1.9 298 21 313 165 5.4 0.2 5.7 4.8 02/19/2006 12:40:00 3.7 0.6 5.3 2.3 3.7 0.6 4.9 2.3 3.3 0.6 4.9 1.9 308 9 308 165 5.2 0 5.7 5 02/19/2006 12:50:00 2.9 0.5 4.2 1.5 2.9 0.6 4.2 1.5 2.6 0.5 3.8 1.5 312 9 302 165 5.6 0 5.7 5.2 02/19/2006 13:00:00 3.4 0.4 4.2 2.3 3.4 0.4 4.2 2.3 2.9 0.4 3.8 1.9 305 6 311 165 5.6 0.1 5.7 5.5 02/19/2006 13:10:00 3.7 0.5 4.9 2.6 3.8 0.5 5.3 2.6 3 0.5 4.6 1.9 300 8 309 165 5.7 0.1 6 5.5 02/19/2006 13:20:00 3.3 0.8 4.9 1.1 3.8 0.8 5.3 1.9 3.4 0.9 5.3 1.5 274 18 285 165 5.9 0 6.2 5.7 02/19/2006 13:30:00 3.8 0.6 5.7 2.3 4.9 0.7 6.8 3.4 4.7 0.8 6.5 3 260 11 228 165 5.9 0.2 6.7 5.5 02/19/2006 13:40:00 3.8 0.7 5.3 1.9 4.5 0.6 5.7 2.3 4.4 0.6 6.1 2.6 260 9 274 165 5.7 0.1 6.2 5.5 02/19/2006 13:50:00 3.6 0.7 5.7 1.9 4 0.6 5.7 2.3 3.8 0.6 5.3 2.3 249 14 244 165 5.9 0 6 5.2 02/19/2006 14:00:00 3.8 1 6.5 1.9 4.3 0.9 6.5 2.3 4.1 0.8 6.5 2.3 257 15 247 165 5.7 0 6 5.5 02/19/2006 14:10:00 4.1 0.7 6.1 2.3 4.4 0.6 6.1 2.6 4 0.7 6.1 2.3 278 9 275 165 5.6 0.1 6 5 02/19/2006 14:20:00 3.5 0.9 6.1 1.9 3.8 1 6.1 1.9 3.5 0.8 6.1 1.9 276 11 286 165 5.8 0.2 6.2 5.2 02/19/2006 14:30:00 5 1 7.2 2.6 5 1 7.2 2.6 4.4 1 6.5 1.9 288 13 295 165 5.2 0.1 5.5 4.8 02/19/2006 14:40:00 5.3 0.8 6.5 2.6 5.3 0.8 6.8 3 4.4 1 6.8 1.9 293 7 299 165 4.8 0.2 5.2 4.3 02/19/2006 14:50:00 4.2 0.8 6.1 2.3 4.3 0.8 6.5 2.3 3.5 0.9 6.8 1.5 297 9 291 165 5.1 0.1 5.5 4.8 02/19/2006 15:00:00 4.5 0.8 6.5 2.3 4.5 0.8 6.1 2.6 3.7 0.8 5.3 1.5 298 9 316 165 5.1 0.1 5.5 4.5 02/19/2006 15:10:00 6.1 1 8.4 3.8 6.1 1 8.4 3.4 4.9 0.9 6.8 2.6 301 8 305 165 4.9 0 5 4.5 02/19/2006 15:20:00 7 1 9.5 4.6 6.9 1 9.5 4.6 5.9 1.1 8.8 3 305 7 321 165 4.6 0.1 4.8 4.3 02/19/2006 15:30:00 6.9 1.1 9.1 4.6 6.9 1.1 9.1 4.6 5.4 1 8 3.4 299 7 307 165 4.6 0.1 5.2 4 02/19/2006 15:40:00 6.3 1 8.8 4.2 6.3 0.9 8.4 4.2 5.2 1 8.4 3 290 6 295 165 4.6 0 5.2 4.3 02/19/2006 15:50:00 7.2 1.2 10.7 4.6 7.1 1.1 10.7 4.6 6.4 1.5 9.9 3.4 300 16 322 165 4.5 0 5 4.3 02/19/2006 16:00:00 5.2 2.2 8.8 1.1 4.9 2.1 8.8 0.7 5.1 2.4 10.3 0.7 339 29 334 165 5.1 0.1 5.5 4.8 02/19/2006 16:10:00 5.5 1.1 8.8 3 5.5 1 8.8 3.4 4.9 1 7.2 3 308 10 297 165 4.9 0.3 5.5 4.3 02/19/2006 16:20:00 6.2 1.1 9.9 3.4 6.1 1.1 9.5 3.4 5.5 1.3 10.7 2.6 309 16 301 165 4.4 0 4.8 3.8 02/19/2006 16:30:00 5.8 0.8 7.2 3 5.8 0.8 7.6 3 4.8 0.8 6.8 3 305 7 296 165 4.1 0.1 4.5 3.8 02/19/2006 16:40:00 6.6 0.6 8.8 4.6 6.5 0.7 8.4 4.6 5.6 0.8 7.6 3.8 307 6 305 165 3.6 0.1 3.8 3.5 02/19/2006 16:50:00 5.6 0.9 7.6 3.8 5.5 0.9 7.6 3.8 5 0.8 7.2 3.4 311 8 318 165 3.5 0.1 3.8 3.3 02/19/2006 17:00:00 4.5 0.8 6.8 2.6 4.4 0.8 6.5 2.6 4 1 6.1 1.9 311 11 313 165 3.7 0 4 3.5 02/19/2006 17:10:00 4.5 0.7 6.1 3 4.4 0.7 6.1 3 3.7 0.9 6.1 1.9 304 8 312 165 3.4 0 3.8 3.3 02/19/2006 17:20:00 4.3 0.7 5.7 2.3 4.3 0.7 5.7 2.6 3.5 0.6 5.3 2.3 297 8 302 165 3.1 0 3.3 3 02/19/2006 17:30:00 3.4 0.6 5.3 2.3 3.4 0.6 5.3 1.9 2.9 0.6 4.9 1.5 296 10 295 165 3 0.1 3.3 2.8 02/19/2006 17:40:00 2.4 0.4 3.4 1.1 2.4 0.4 3.4 1.1 2.1 0.4 3.4 1.1 305 9 300 165 2.9 0 3 2.8 02/19/2006 17:50:00 2.9 0.4 3.8 1.9 2.9 0.4 3.8 1.9 2.4 0.5 3.4 1.1 295 11 302 165 2.7 0 2.8 2.6 02/19/2006 18:00:00 2.2 0.3 3 1.5 2.3 0.3 3 1.5 1.8 0.4 2.6 0.7 300 16 306 165 2.6 0 2.8 2.6 02/19/2006 18:10:00 2.4 0.3 3.4 1.9 2.4 0.3 3.4 1.5 2.4 0.4 3.4 1.5 318 6 319 165 2.5 0 2.8 2.6 02/19/2006 18:20:00 2.9 0.4 3.8 1.9 2.9 0.4 3.8 1.9 2.1 0.4 3 1.1 304 7 305 165 2.4 0 2.8 2.3 02/19/2006 18:30:00 1.9 0.5 3 0.7 2 0.5 3 1.1 1.5 0.6 3 0.7 301 6 309 165 2.4 0 2.6 2.3 02/19/2006 18:40:00 0.9 0.5 2.6 0.4 1 0.5 2.6 0.4 0.7 0.4 1.9 0.4 293 13 258 165 2.4 0 2.6 2.3 02/19/2006 18:50:00 1.5 0.7 3 0.4 1.4 0.6 2.6 0.4 1.5 0.6 3 0.4 323 33 357 165 2.3 0 2.6 2.3 02/19/2006 19:00:00 0.9 0.6 3 0.4 1 0.6 2.6 0.4 0.8 0.5 2.3 0.4 291 35 307 165 2.3 0 2.6 2.1 02/19/2006 19:10:00 0.9 0.5 2.3 0.4 1 0.5 2.3 0.4 1 0.6 2.6 0.4 341 58 354 165 2.4 0 2.6 2.1 02/19/2006 19:20:00 1 0.9 3.4 0.4 1.4 1.2 4.6 0.4 1.1 0.9 3.8 0.4 282 38 242 165 2.2 0 2.3 2.1 02/19/2006 19:30:00 2.4 0.8 4.2 0.7 2.8 1 4.9 0.7 2.6 0.9 4.9 0.7 264 12 248 165 2.4 0.1 2.8 2.3 02/19/2006 19:40:00 1.9 0.6 3 0.4 2.4 0.6 3.4 0.4 1.9 0.7 3.4 0.4 269 15 241 165 2.6 0 2.8 2.3 02/19/2006 19:50:00 2 0.5 3.4 1.1 2.5 0.5 3.8 1.5 2.1 0.5 3.4 0.7 265 5 263 165 2.7 0 2.8 2.6 02/19/2006 20:00:00 2.7 0.7 4.2 0.7 3.3 0.6 4.6 1.5 2.9 0.6 4.2 1.9 265 6 277 165 2.8 0 3 2.6 02/19/2006 20:10:00 1 0.8 3 0.4 1.3 1 3.4 0.4 1.2 0.9 3.4 0.4 249 20 255 165 2.5 0.2 2.8 2.3 02/19/2006 20:20:00 1 0.7 2.6 0.4 1 0.7 2.6 0.4 1.1 0.6 2.6 0.4 181 15 177 165 2.1 0 2.3 1.8 02/19/2006 20:30:00 2.1 0.4 3 1.1 2 0.4 3 1.1 2.2 0.4 3 1.5 168 7 163 165 2.2 0 2.3 2.1 02/19/2006 20:40:00 2 0.3 2.6 1.5 2 0.3 2.6 1.5 2.1 0.2 2.6 1.5 163 2 166 165 2.3 0 2.6 2.3 02/19/2006 20:50:00 2.3 0.2 2.6 1.9 2.2 0.2 2.6 1.9 2.4 0.2 3 1.9 162 6 164 165 2.3 0 2.3 2.3 02/19/2006 21:00:00 1.6 0.3 2.3 1.1 1.7 0.3 2.6 1.1 1.8 0.3 2.6 0.7 166 11 167 165 2.3 0 2.6 2.3 02/19/2006 21:10:00 0.7 0.5 1.9 0.4 0.9 0.5 2.3 0.4 0.8 0.5 1.9 0.4 117 49 124 165 2.4 0 2.8 2.3 02/19/2006 21:20:00 0.6 0.3 1.5 0.4 0.8 0.4 1.9 0.4 0.8 0.4 1.9 0.4 102 19 83 165 2.6 0 2.8 2.6 02/19/2006 21:30:00 0.9 0.5 1.9 0.4 1.2 0.5 1.9 0.4 1.3 0.2 1.9 0.4 80 23 113 165 2.4 0 2.6 2.3 02/19/2006 21:40:00 0.6 0.4 1.9 0.4 0.7 0.4 1.9 0.4 0.8 0.5 1.9 0.4 90 45 119 165 2.3 0 2.6 2.3 02/19/2006 21:50:00 0.6 0.3 1.5 0.4 0.5 0.3 1.5 0.4 0.7 0.4 1.5 0.4 154 8 135 165 2.2 0 2.6 2.1 02/19/2006 22:00:00 1.5 0.4 2.3 0.4 1.4 0.4 2.3 0.4 1.6 0.4 2.6 0.7 158 9 157 165 2.4 0 2.6 2.3 02/19/2006 22:10:00 2.5 0.3 3.4 1.5 2.6 0.3 3.4 1.9 2.5 0.4 3 1.5 162 3 164 165 2.4 0 2.6 2.3 02/19/2006 22:20:00 2 0.3 2.6 1.5 2.1 0.3 2.6 1.5 2 0.4 3 1.1 171 8 176 165 2.3 0 2.6 2.3 02/19/2006 22:30:00 1.8 0.4 2.6 1.1 1.9 0.3 2.6 1.1 1.9 0.4 2.6 0.7 178 13 173 165 2.4 0 2.6 2.1 02/19/2006 22:40:00 2.2 0.3 2.6 1.5 2.3 0.2 2.6 1.5 2.4 0.2 3 1.9 187 9 198 165 2.4 0.1 2.8 2.3 02/19/2006 22:50:00 2.1 0.2 2.6 1.5 2.2 0.2 2.6 1.5 2.4 0.2 2.6 1.5 182 2 181 165 2.6 0 2.8 2.6 02/19/2006 23:00:00 2.2 0.3 2.6 1.1 2.1 0.3 2.6 1.1 2.4 0.3 3 1.5 174 5 180 165 2.4 0 2.6 2.3 02/19/2006 23:10:00 1.5 0.5 2.6 0.4 1.5 0.5 2.6 0.4 1.7 0.5 3 0.7 185 13 192 165 2.4 0 2.6 2.3 02/19/2006 23:20:00 1.6 0.4 2.6 0.7 1.7 0.3 2.6 0.7 1.8 0.3 2.6 0.7 176 7 196 165 2.6 0 2.8 2.3 02/19/2006 23:30:00 2 0.4 3 0.7 2 0.4 3 0.7 2.1 0.4 3 0.7 212 15 215 165 2.6 0.1 2.8 2.6 02/19/2006 23:40:00 2.7 0.3 3.4 1.9 2.8 0.3 3.4 2.3 2.8 0.4 3.4 1.9 230 7 223 165 2.7 0 2.8 2.3 02/19/2006 23:50:00 2.2 0.3 3 1.5 2.2 0.3 3 1.5 2.3 0.2 2.6 1.9 231 5 242 165 2.8 0 2.8 2.6 02/20/2006 00:00:00 2.1 0.2 2.6 1.9 2.2 0.2 2.6 1.9 2.3 0.2 2.6 1.9 224 2 225 165 2.5 0.1 2.8 2.3 02/20/2006 00:10:00 2.4 0.3 3 1.9 2.4 0.2 3 1.9 2.3 0.3 3 1.5 236 7 242 165 2.7 0 2.8 2.6 02/20/2006 00:20:00 1.7 0.4 2.6 0.7 1.8 0.3 2.6 1.1 1.8 0.3 2.3 1.1 250 5 240 165 2.9 0 3 2.8 02/20/2006 00:30:00 1.4 0.5 2.6 0.4 1.6 0.4 2.6 0.4 1.6 0.4 2.6 0.4 260 9 246 165 2.9 0 3 2.8 02/20/2006 00:40:00 2.4 0.5 3.4 1.1 2.8 0.4 3.8 1.5 2.4 0.4 3.4 1.1 253 6 242 165 2.7 0 2.8 2.6 02/20/2006 00:50:00 2 0.5 3 1.1 2.2 0.4 3.4 1.1 2.1 0.4 3 1.1 280 8 268 165 2.7 0 2.8 2.6 02/20/2006 01:00:00 1.6 0.3 2.6 0.7 1.8 0.3 2.6 1.1 1.7 0.4 2.6 0.7 274 8 278 165 2.7 0 2.8 2.6 02/20/2006 01:10:00 1.6 0.4 2.6 0.4 1.9 0.4 3 0.7 1.8 0.4 3 0.4 261 10 248 165 2.9 0 3 2.8 02/20/2006 01:20:00 2.4 0.5 3.4 0.7 2.5 0.4 3.4 1.5 2.3 0.4 3.4 1.5 237 9 227 165 3 0 3.3 2.8 02/20/2006 01:30:00 1.8 0.5 3 0.4 2.1 0.4 3 0.7 1.9 0.5 3 0.7 255 12 226 165 3 0 3.3 2.8 02/20/2006 01:40:00 0.7 0.3 1.5 0.4 0.9 0.4 1.9 0.4 0.8 0.4 1.9 0.4 265 12 272 165 3 0 3.3 2.8 02/20/2006 01:50:00 0.9 0.4 1.9 0.4 0.9 0.4 1.9 0.4 1 0.5 2.3 0.4 244 12 245 165 3 0 3.3 2.8 02/20/2006 02:00:00 0.5 0.2 1.9 0.4 0.4 0.2 1.9 0.4 0.4 0.1 1.1 0.4 224 15 242 165 2.7 0 2.8 2.6 02/20/2006 02:10:00 0.4 0.1 1.1 0.4 0.4 0 0.4 0.4 0.4 0.1 1.1 0.4 179 17 164 165 2.8 0 2.8 2.6 02/20/2006 02:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 160 4 165 165 2.7 0 2.8 2.6 02/20/2006 02:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 157 0 165 165 2.6 0 2.8 2.6 02/20/2006 02:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 157 0 165 165 2.5 0 2.8 2.6 02/20/2006 02:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0.1 0.7 0.4 157 0 165 165 2.4 0 2.6 2.3 02/20/2006 03:00:00 0.5 0.2 1.1 0.4 0.4 0.1 0.7 0.4 0.8 0.4 1.5 0.4 109 79 346 165 2.2 0 2.6 2.1 02/20/2006 03:10:00 0.4 0.1 0.7 0.4 0.4 0 0.7 0.4 0.6 0.3 1.5 0.4 350 11 346 165 2.3 0 2.6 2.3 02/20/2006 03:20:00 1 0.5 1.9 0.4 0.8 0.4 1.5 0.4 1.3 0.3 2.3 0.4 20 3 16 165 2.5 0 2.6 2.3 02/20/2006 03:30:00 1.8 0.2 2.3 1.1 1.5 0.5 2.3 0.4 1.8 0.2 2.3 1.1 15 2 12 165 2.4 0 2.6 2.3 02/20/2006 03:40:00 2.4 0.3 3 1.9 2.2 0.4 3 1.5 2.2 0.3 3 1.5 20 3 18 165 2.2 0 2.6 2.1 02/20/2006 03:50:00 2.6 0.2 3 2.3 2.5 0.2 3 1.9 2.9 0.2 3 2.3 24 0 24 165 2.2 0 2.3 2.1 02/20/2006 04:00:00 2.1 0.2 2.6 1.9 2.3 0.2 2.6 1.9 2.4 0.2 3 1.9 24 0 23 165 2.3 0 2.3 2.3 02/20/2006 04:10:00 1.6 0.3 2.3 1.1 1.7 0.4 2.3 1.1 1.8 0.3 2.3 1.1 24 0 24 165 2.4 0 2.6 2.3 02/20/2006 04:20:00 0.6 0.3 1.5 0.4 0.7 0.4 1.5 0.4 0.8 0.4 1.5 0.4 35 9 24 165 2.4 0 2.6 2.3 02/20/2006 04:30:00 0.4 0 0.4 0.4 0.4 0 0.7 0.4 0.4 0 0.4 0.4 63 0 165 165 2.5 0 2.8 2.3 02/20/2006 04:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 63 0 165 165 2.4 0 2.6 2.3 02/20/2006 04:50:00 0.8 0.5 1.9 0.4 0.8 0.5 2.3 0.4 0.8 0.5 1.9 0.4 48 21 63 165 2.2 0 2.3 2.1 02/20/2006 05:00:00 0.9 0.3 1.5 0.4 0.8 0.3 1.9 0.4 0.9 0.3 1.5 0.4 24 2 23 165 2 0.1 2.3 1.8 02/20/2006 05:10:00 0.8 0.4 2.3 0.4 0.7 0.4 1.9 0.4 0.8 0.5 2.6 0.4 9 13 12 165 1.9 0 1.8 1.8 02/20/2006 05:20:00 0.8 0.3 1.5 0.4 0.5 0.3 1.1 0.4 1 0.3 1.9 0.4 12 10 358 165 1.8 0 1.8 1.6 02/20/2006 05:30:00 1 0.4 1.9 0.4 0.4 0.1 1.1 0.4 1 0.4 1.9 0.4 357 2 359 165 1.7 0 1.8 1.6 02/20/2006 05:40:00 2.5 0.4 3.4 1.5 1.9 0.8 3.4 0.4 2.6 0.4 3.4 1.1 11 8 20 165 1.5 0 1.6 1.4 02/20/2006 05:50:00 2.3 0.2 2.6 1.5 2.2 0.2 2.6 1.5 2.4 0.3 3 1.5 25 5 19 165 1.3 0 1.6 1.1 02/20/2006 06:00:00 1.9 0.4 2.6 1.1 1.9 0.4 2.6 0.7 2 0.3 2.6 1.1 32 5 28 165 1 0 1.4 0.9 02/20/2006 06:10:00 0.9 0.6 1.9 0.4 0.9 0.6 1.9 0.4 1.1 0.7 2.3 0.4 54 7 38 165 0.8 0 0.9 0.9 02/20/2006 06:20:00 0.4 0.1 1.1 0.4 0.5 0.2 1.1 0.4 0.4 0.2 1.1 0.4 103 26 119 165 0.8 0 0.9 0.9 02/20/2006 06:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 119 0 165 165 0.8 0 0.9 0.7 02/20/2006 06:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 119 0 165 165 0.5 0 0.9 0.4 02/20/2006 06:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 119 0 165 165 0.5 0 0.7 0.4 02/20/2006 07:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 185 72 165 165 0.3 0 0.7 0.2 02/20/2006 07:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0.2 1.5 0.4 231 15 165 165 0.4 0 0.7 0.2 02/20/2006 07:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.7 0.4 220 0 165 165 0.4 0 0.7 0.2 02/20/2006 07:30:00 0.4 0.2 1.1 0.4 0.4 0 0.4 0.4 0.4 0.1 1.1 0.4 216 9 198 165 0.3 0 0.4 0.2 02/20/2006 07:40:00 0.6 0.3 1.1 0.4 0.4 0.1 1.1 0.4 0.6 0.4 1.5 0.4 179 4 191 165 0.4 0 0.7 0.2 02/20/2006 07:50:00 0.6 0.5 1.9 0.4 0.6 0.4 1.5 0.4 0.7 0.5 1.9 0.4 176 1 172 165 0.4 0 0.7 0.2 02/20/2006 08:00:00 0.8 0.5 1.9 0.4 0.6 0.4 1.5 0.4 0.8 0.4 1.9 0.4 174 0 173 165 0.3 0 0.4 0.2 02/20/2006 08:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 175 0 165 165 0.2 0 0.2 -0.1 02/20/2006 08:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 175 0 165 165 0.2 0 0.2 0.2 02/20/2006 08:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 175 0 165 165 0.2 0 0.4 0.2 02/20/2006 08:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 174 0 165 165 0.1 0 0.2 -0.1 02/20/2006 08:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 174 0 165 165 0.1 0 0.2 -0.1 02/20/2006 09:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 174 0 165 165 0.1 0 0.2 -0.1 02/20/2006 09:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 174 0 165 165 0.2 0.1 0.7 0.2 02/20/2006 09:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 174 0 165 165 1.4 0.4 2.1 0.7 02/20/2006 09:30:00 0.4 0 0.7 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 103 90 354 165 1.7 0.3 2.3 1.4 02/20/2006 09:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 354 0 165 165 1.2 0 1.4 0.9 02/20/2006 09:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 354 0 165 165 1.1 0 1.4 1.1 02/20/2006 10:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 354 0 165 165 1.4 0 1.6 1.4 02/20/2006 10:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 354 0 165 165 1.4 0 1.6 1.4 02/20/2006 10:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 281 16 165 165 1.7 0.1 1.8 1.6 02/20/2006 10:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 243 43 165 165 2 0 2.3 1.8 02/20/2006 10:40:00 0.4 0.1 1.1 0.4 0.4 0.1 1.1 0.4 0.4 0 0.4 0.4 233 33 239 165 2.1 0 2.3 1.8 02/20/2006 10:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 128 0 165 165 1.9 0 2.1 1.8 02/20/2006 11:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.7 0.4 128 0 165 165 2.4 0.3 2.8 1.8 02/20/2006 11:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 128 0 165 165 2.7 0 2.8 2.6 02/20/2006 11:20:00 0.5 0.4 1.9 0.4 0.5 0.5 2.6 0.4 0.6 0.5 2.6 0.4 357 94 260 165 2.5 0.2 2.8 1.8 02/20/2006 11:30:00 0.8 0.6 3 0.4 0.7 0.5 3 0.4 0.8 0.5 2.3 0.4 295 43 316 165 2 0 2.1 1.8 02/20/2006 11:40:00 3.3 1 5.3 0.7 3.3 1 5.3 1.1 2.7 0.9 4.9 0.4 310 11 304 165 1.8 0 1.8 1.6 02/20/2006 11:50:00 3.9 0.5 5.3 2.6 3.9 0.5 4.9 2.6 3.4 0.6 4.9 1.9 306 7 307 165 1.9 0 1.8 1.8 02/20/2006 12:00:00 4.3 0.5 5.3 2.6 4.2 0.5 5.3 2.6 3.4 0.5 4.9 2.3 303 6 307 165 2.1 0 2.6 1.8 02/20/2006 12:10:00 4.3 0.5 5.3 3 4.3 0.5 5.3 3 3.5 0.6 4.9 2.3 295 6 299 165 2.3 0 2.6 2.1 02/20/2006 12:20:00 5.1 0.5 6.8 3.8 5.1 0.5 6.5 3.8 4 0.7 6.1 2.3 303 5 301 165 2.2 0 2.6 2.1 02/20/2006 12:30:00 6 0.6 7.6 3.8 5.9 0.6 7.2 3.8 4.5 0.6 6.5 3 299 5 301 165 2.3 0 2.6 2.1 02/20/2006 12:40:00 7.5 0.9 9.5 5.3 7.4 0.9 9.1 5.3 6.4 1.1 8.4 3.8 307 6 310 165 2.1 0 2.3 1.8 02/20/2006 12:50:00 7.7 0.6 9.1 5.3 7.7 0.6 9.1 5.3 6.3 0.8 8 3.4 306 5 307 165 2.1 0 2.3 1.8 02/20/2006 13:00:00 8.3 0.6 9.9 6.5 8.2 0.6 9.9 6.5 6.4 0.7 8.8 4.6 304 4 307 165 2 0 2.3 1.8 02/20/2006 13:10:00 8 0.6 9.9 6.5 7.9 0.6 9.9 6.5 6.5 1 8.4 4.6 306 5 302 165 2.3 0 2.6 2.1 02/20/2006 13:20:00 7.8 0.6 9.1 6.1 7.7 0.6 9.1 6.1 7.1 1 9.1 4.6 311 6 312 165 2.4 0.2 2.8 1.8 02/20/2006 13:30:00 8.1 0.8 10.7 6.1 8.1 0.8 10.3 5.7 7 1 9.5 4.2 308 5 311 165 2.6 0 2.8 2.6 02/20/2006 13:40:00 9 0.7 10.3 6.5 8.8 0.7 10.3 6.5 8.5 1 10.7 4.9 313 5 313 165 2.5 0 2.8 2.3 02/20/2006 13:50:00 8.9 0.7 10.7 6.8 8.7 0.7 10.7 6.8 8.5 0.7 10.3 6.1 316 5 311 165 2.4 0 2.6 2.3 02/20/2006 14:00:00 7.8 1 9.9 5.3 7.7 1 9.9 5.3 7 1.2 9.1 3.8 309 9 310 165 2.4 0 2.6 2.3 02/20/2006 14:10:00 9 1.1 11.1 6.1 8.9 1.1 11.1 5.7 7 0.9 9.1 4.9 302 8 286 165 2.5 0 2.8 2.6 02/20/2006 14:20:00 7.5 0.9 9.9 4.9 7.4 0.9 9.9 4.9 6.4 1 8.8 4.2 304 7 292 165 2.7 0 3 2.6 02/20/2006 14:30:00 6.8 0.6 9.1 5.3 6.7 0.6 9.1 4.9 6.3 0.9 8.4 3.8 310 6 305 165 2.9 0 3 2.8 02/20/2006 14:40:00 5.4 0.6 7.2 3.8 5.3 0.7 7.2 3.8 4.8 0.9 7.2 3 305 8 313 165 2.6 0.1 2.8 2.6 02/20/2006 14:50:00 4.5 0.6 6.1 2.6 4.5 0.6 5.7 2.6 3.7 0.8 5.7 1.9 294 8 303 165 2.4 0 2.6 2.3 02/20/2006 15:00:00 4.4 0.8 6.5 2.6 4.6 0.8 6.5 2.6 4 0.9 6.1 2.3 286 12 285 165 2.4 0 2.6 2.3 02/20/2006 15:10:00 5.5 0.9 7.2 3 6 0.6 7.6 4.2 5.5 0.8 7.6 3 279 10 295 165 2.2 0 2.6 2.1 02/20/2006 15:20:00 5.4 2.1 9.9 1.9 6 1.7 10.3 3 5.5 1.6 9.9 3 272 13 287 165 2.2 0 2.3 1.8 02/20/2006 15:30:00 9.7 1.8 13 5.3 9.8 1.8 13 5.3 8.6 2 13.3 4.2 289 9 292 165 2.3 0 2.6 2.3 02/20/2006 15:40:00 8.9 1.7 13.3 6.1 9 1.7 13.7 6.1 7.7 2 13.7 3.8 290 10 273 165 2.3 0 2.6 2.3 02/20/2006 15:50:00 7.7 1.3 10.3 4.6 7.9 1.3 10.7 4.6 7.4 1.7 11.1 3 281 8 276 165 2.1 0 2.3 1.8 02/20/2006 16:00:00 7.7 1 10.3 4.6 8 1 10.3 4.6 7.9 1.2 10.3 4.2 277 6 273 165 2 0 2.3 1.8 02/20/2006 16:10:00 6.6 1.3 10.3 3.8 7.1 1.5 11.5 4.2 6.4 1.7 11.1 2.6 281 14 286 165 2 0 2.3 1.8 02/20/2006 16:20:00 7 1.3 10.3 3.4 7.2 1.3 11.1 3.8 6.5 1.5 11.1 2.6 285 11 279 165 2.2 0 2.3 2.1 02/20/2006 16:30:00 5.6 1.7 8.8 2.3 5.7 1.7 9.1 2.3 5.3 1.6 8.8 1.9 301 15 287 165 2.4 0.1 2.8 2.1 02/20/2006 16:40:00 6.8 1.7 10.3 3.4 6.8 1.6 10.3 3.8 5.7 1.3 10.3 3 307 10 325 165 2.6 0.1 2.8 2.3 02/20/2006 16:50:00 5 1.2 7.2 2.3 5 1.1 7.2 2.3 4.4 1 7.2 1.9 302 15 318 165 2.4 0 2.6 2.3 02/20/2006 17:00:00 6.8 1.7 10.7 3.4 6.7 1.6 10.7 3.8 5.7 1.3 9.5 2.6 305 11 307 165 2.3 0 2.6 2.1 02/20/2006 17:10:00 6.2 1.3 8.8 3.8 6.2 1.3 8.8 3.8 5.2 1.3 8.8 2.6 299 9 289 165 2 0.1 2.3 1.8 02/20/2006 17:20:00 4.4 0.8 6.5 2.3 4.3 0.8 6.1 2.3 3.9 1 5.7 1.9 306 22 315 165 1.7 0 1.8 1.4 02/20/2006 17:30:00 4.5 1.1 7.2 1.5 4.5 1.1 7.6 1.5 4 1 7.2 1.1 301 19 315 165 1.4 0 1.6 1.4 02/20/2006 17:40:00 5 1.3 8 1.5 5.1 1.2 7.6 2.6 4.6 1 8.4 1.9 286 17 288 165 1.2 0 1.4 1.1 02/20/2006 17:50:00 5.7 1.5 8.8 2.3 5.8 1.4 8.8 2.6 5.1 1.3 9.1 2.6 286 10 281 165 1 0 1.4 0.9 02/20/2006 18:00:00 5.7 1.2 9.9 2.6 5.8 1.1 10.3 3.4 5.2 1.2 8.4 3 282 8 277 165 0.9 0 1.1 0.9 02/20/2006 18:10:00 5.5 1.3 9.1 2.3 5.9 1.6 10.7 2.6 5.6 1.5 10.7 1.9 276 15 273 165 0.8 0 1.1 0.7 02/20/2006 18:20:00 7.6 1.7 13.3 4.2 7.7 1.6 13 4.9 6.7 1.5 11.5 3.8 285 11 285 165 0.8 0 0.9 0.9 02/20/2006 18:30:00 7.1 1.7 12.2 4.2 7.2 1.7 12.6 4.2 6.2 1.5 11.1 3 292 11 282 165 0.9 0.1 1.4 0.7 02/20/2006 18:40:00 7.2 1.3 10.3 3.8 7.8 1.3 11.1 4.6 7.2 1.3 10.3 3.8 276 9 272 165 0.8 0 0.9 0.7 02/20/2006 18:50:00 8.6 1.3 12.2 5.3 8.8 1.2 12.2 5.7 7.7 1.3 11.1 4.2 284 9 299 165 0.9 0 1.4 0.9 02/20/2006 19:00:00 10.8 1.8 15.6 6.8 10.8 1.8 15.6 6.8 9.2 1.9 14.1 4.6 290 10 299 165 1.3 0 1.4 0.9 02/20/2006 19:10:00 11.2 1.5 15.3 7.2 11.2 1.5 15.3 7.6 9.3 1.6 13.3 5.3 295 9 287 165 1.4 0 1.6 1.1 02/20/2006 19:20:00 9.8 1.2 14.1 7.2 9.8 1.2 14.5 7.2 8.2 1.4 13.3 5.3 299 9 307 165 1.2 0 1.4 1.1 02/20/2006 19:30:00 9.6 1.2 13.3 6.8 9.6 1.2 13.3 6.5 7.9 1.4 12.6 5.3 300 12 292 165 1.2 0 1.4 0.9 02/20/2006 19:40:00 9.9 1.2 13 6.8 9.8 1.2 13 6.8 7.9 1.6 13.3 4.9 300 10 316 165 1.2 0 1.4 0.9 02/20/2006 19:50:00 9 1.7 13.3 4.2 9 1.7 13.7 4.9 7.9 2 13.3 3.8 293 13 300 165 1.2 0 1.4 0.9 02/20/2006 20:00:00 10.4 2.6 16.8 5.3 10.3 2.7 16.4 5.3 8.9 2.2 14.1 4.2 307 9 302 165 1.1 0.1 1.4 0.9 02/20/2006 20:10:00 13.8 1.8 17.9 9.5 13.7 1.7 17.9 9.9 11.8 1.8 16.4 6.5 307 8 301 165 1.4 0 1.6 1.4 02/20/2006 20:20:00 16 2.3 22.6 11.5 15.9 2.3 22.1 11.5 13.4 2.2 20.2 8.4 306 7 305 165 1.5 0 1.6 1.4 02/20/2006 20:30:00 18.1 2.4 22.9 11.5 18 2.5 22.9 11.1 14.6 2.8 24.4 8.8 302 8 311 165 1.5 0 1.6 1.4 02/20/2006 20:40:00 16.7 1.7 21.8 12.2 16.6 1.7 21.8 12.2 14.7 2.5 20.6 8.8 305 9 310 165 1.4 0 1.6 1.4 02/20/2006 20:50:00 17.2 2.4 22.9 11.8 17.1 2.4 22.6 11.8 14.5 2.4 20.2 8.8 303 9 298 165 1.4 0 1.6 1.1 02/20/2006 21:00:00 14.8 2 21 9.5 14.7 2 20.6 9.9 12.1 2.1 19.9 7.2 298 9 291 165 1.2 0 1.4 0.9 02/20/2006 21:10:00 15.2 1.8 19.9 10.3 15.3 1.8 20.2 10.3 12.8 2.4 18.7 7.2 295 10 289 165 1 0 1.4 0.9 02/20/2006 21:20:00 12.5 1.9 17.6 8.8 12.4 1.9 17.6 8.4 11 2.1 16.8 6.1 307 9 312 165 0.8 0 0.9 0.7 02/20/2006 21:30:00 13.4 1.7 19.5 8 13.3 1.7 18.7 8.4 11.9 1.9 16.4 7.2 308 8 298 165 0.6 0 0.7 0.4 02/20/2006 21:40:00 13.9 1.8 18.3 9.9 13.9 1.8 17.9 9.5 11.8 1.8 16.4 6.8 306 8 298 165 0.4 0 0.7 0.2 02/20/2006 21:50:00 13.1 1.7 17.2 8 13.1 1.7 17.2 7.6 10.8 1.7 15.3 7.6 302 9 304 165 0.4 0.1 0.7 0.2 02/20/2006 22:00:00 11.9 1.6 16.1 7.6 11.9 1.6 16.4 8 9.8 1.7 14.9 5.7 294 9 291 165 0.1 0 0.2 -0.1 02/20/2006 22:10:00 10.9 1.7 16.4 6.5 10.8 1.7 16.4 6.8 9 1.7 13.7 5.7 294 10 301 165 -0.1 0 0.2 -0.3 02/20/2006 22:20:00 12.3 1.3 15.3 8.8 12.3 1.3 15.3 8 9.9 1.5 14.5 6.8 293 8 301 165 -0.2 0.1 -0.1 -0.3 02/20/2006 22:30:00 11.5 1.7 16.4 8 11.5 1.8 16.1 7.6 10.2 2.1 16.1 6.1 298 13 319 165 -0.3 0 -0.1 -0.5 02/20/2006 22:40:00 11.2 1.6 15.3 7.2 11.1 1.6 15.6 6.8 9.6 1.9 15.6 6.1 300 11 274 165 -0.3 0 -0.3 -0.5 02/20/2006 22:50:00 10.8 1.8 17.2 7.6 10.8 1.8 17.2 7.2 9 1.8 16.4 5.3 300 9 290 165 -0.5 0 -0.3 -0.5 02/20/2006 23:00:00 9.8 1.5 13.3 5.7 9.7 1.5 13.7 5.3 8.6 1.5 13.3 3.8 304 11 297 165 -0.6 0 -0.5 -0.8 02/20/2006 23:10:00 7.4 1.2 10.3 4.2 7.4 1.2 10.3 4.6 6.5 1 9.1 4.6 304 13 290 165 -0.8 0.1 -0.5 -1 02/20/2006 23:20:00 8.7 1.7 13.7 4.6 8.6 1.7 13.3 4.6 7.8 1.7 14.5 3.4 305 13 304 165 -0.9 0 -0.8 -1 02/20/2006 23:30:00 11.6 2.7 17.9 6.5 11.5 2.7 17.6 6.1 10.5 2.7 16.8 4.2 309 8 295 165 -0.9 0 -0.8 -1 02/20/2006 23:40:00 12.7 1.3 17.9 9.5 12.6 1.3 17.6 9.5 11 1.8 17.2 6.8 309 8 310 165 -0.9 0 -0.8 -1.2 02/20/2006 23:50:00 13.5 1.2 16.4 9.5 13.4 1.3 16.4 9.5 10.8 1.6 14.9 7.2 304 7 305 165 -0.9 0 -0.8 -1.2 02/21/2006 00:00:00 13.3 1.6 18.3 9.5 13.2 1.6 17.9 9.5 10.6 2 16.8 5.7 303 9 302 165 -1 0 -0.8 -1.2 02/21/2006 00:10:00 13 2.2 18.7 8 13 2.2 18.3 8 10.8 2 16.4 6.5 303 9 298 165 -1 0 -0.8 -1.2 02/21/2006 00:20:00 12.3 1.7 17.2 8 12.2 1.7 16.8 8 10.4 1.8 15.6 6.1 306 7 310 165 -1.1 0 -1 -1.4 02/21/2006 00:30:00 14.3 2.4 23.3 8.4 14.2 2.5 24 8.4 11.9 2.4 19.9 6.1 304 9 308 165 -1.1 0 -1 -1.4 02/21/2006 00:40:00 15.3 1.6 19.1 11.1 15.2 1.6 18.7 11.1 12.3 2.2 17.9 7.6 302 7 313 165 -1.1 0 -1 -1.2 02/21/2006 00:50:00 13.4 1.8 19.1 8.8 13.4 1.8 19.1 8.8 10.9 2.2 17.9 6.8 303 8 307 165 -1.3 0.1 -1 -1.4 02/21/2006 01:00:00 12.5 1.7 17.6 8 12.5 1.6 17.9 8.4 10.1 1.7 16.1 6.5 296 9 281 165 -1.4 0 -1.2 -1.4 02/21/2006 01:10:00 12.5 1.6 16.8 8 12.5 1.6 16.4 7.6 10 1.7 14.1 6.1 302 8 303 165 -1.5 0 -1.4 -1.7 02/21/2006 01:20:00 14.3 2 19.1 8 14.3 2 19.5 8.8 11.9 1.9 16.8 7.6 292 9 300 165 -1.5 0 -1.4 -1.7 02/21/2006 01:30:00 14.4 2.6 20.2 8.4 14.3 2.6 19.9 8 11.3 2.4 17.9 5.7 300 7 301 165 -1.5 0 -1.4 -1.7 02/21/2006 01:40:00 14.4 2.2 19.5 9.9 14.4 2.2 19.5 9.5 11.4 2.2 18.3 6.8 300 8 297 165 -1.6 0 -1.4 -1.9 02/21/2006 01:50:00 14.5 1.9 18.7 9.9 14.4 2 18.7 9.9 12.1 2 16.8 8 304 8 310 165 -1.6 0 -1.4 -1.7 02/21/2006 02:00:00 15.6 1.7 19.5 10.7 15.6 1.7 19.9 10.7 12.9 1.8 18.3 8.8 301 9 291 165 -1.6 0 -1.4 -1.7 02/21/2006 02:10:00 16.9 2.1 22.1 10.7 16.8 2.1 21.8 10.3 14 2.2 20.6 8.8 304 8 313 165 -1.7 0 -1.4 -1.9 02/21/2006 02:20:00 16.4 2 23.7 11.1 16.3 2.1 23.3 10.7 12.9 2.2 22.9 8.4 302 7 300 165 -1.7 0 -1.4 -1.9 02/21/2006 02:30:00 16.1 1.8 21.4 10.3 16.1 1.9 21.8 10.7 12.6 1.9 17.9 8.4 301 7 302 165 -1.7 0 -1.4 -1.9 02/21/2006 02:40:00 17.1 2.1 22.1 12.6 17 2.1 22.1 12.2 14.9 2.9 21.4 8.8 306 7 307 165 -1.8 0.1 -1.4 -1.9 02/21/2006 02:50:00 16.5 2.1 21.8 11.5 16.4 2.1 21.4 11.8 13.5 1.9 19.1 8 303 7 302 165 -2 0 -1.9 -2.1 02/21/2006 03:00:00 17.3 2.1 22.1 12.6 17.2 2.1 22.1 12.2 13.6 2.2 21.8 8.4 299 7 291 165 -2 0 -1.9 -2.1 02/21/2006 03:10:00 16.4 1.8 20.6 12.2 16.3 1.9 20.6 12.2 13 1.7 17.9 8.4 302 8 302 165 -2.1 0 -1.9 -2.1 02/21/2006 03:20:00 17.2 1.9 22.6 11.8 17.1 1.9 22.1 11.5 14.1 2.3 21 9.1 302 7 298 165 -2.1 0 -1.9 -2.1 02/21/2006 03:30:00 17.1 2 22.9 12.2 17 2 22.9 12.2 14 2.5 21.8 8 302 9 294 165 -2.2 0 -1.9 -2.4 02/21/2006 03:40:00 18.6 2 22.6 12.6 18.6 2 22.9 12.6 14.8 2 20.2 9.1 299 8 291 165 -2.3 0 -2.1 -2.6 02/21/2006 03:50:00 16.2 2.7 22.9 10.3 16.1 2.7 22.9 9.9 13.8 2.4 22.1 8.4 307 8 307 165 -2.4 0 -2.1 -2.6 02/21/2006 04:00:00 17.3 2 22.6 11.8 17.2 2.1 22.6 11.5 14.3 2.1 21.4 9.9 303 9 292 165 -2.4 0.1 -2.1 -2.6 02/21/2006 04:10:00 16.5 2.1 22.6 10.7 16.4 2.1 22.6 11.1 13.2 1.8 18.7 8.8 301 8 295 165 -2.4 0 -2.1 -2.6 02/21/2006 04:20:00 14.5 1.9 19.9 9.9 14.4 1.9 19.5 10.3 11.8 1.9 17.9 7.6 302 8 298 165 -2.5 0 -2.4 -2.6 02/21/2006 04:30:00 12.6 1.5 17.2 9.5 12.5 1.5 17.2 9.5 10.7 1.7 15.6 6.8 306 9 329 165 -2.6 0 -2.4 -2.8 02/21/2006 04:40:00 13.6 2.2 19.1 9.1 13.5 2.2 19.1 9.1 12.4 2 16.4 7.2 312 6 301 165 -2.6 0.1 -2.6 -2.8 02/21/2006 04:50:00 15.1 1.6 19.5 11.5 15.1 1.6 19.1 11.8 13.6 2.1 18.7 8.8 310 7 309 165 -2.5 0 -2.6 -2.6 02/21/2006 05:00:00 16.9 1.8 21.8 11.8 16.8 1.9 21 11.5 13.3 2.6 20.2 8.8 302 7 304 165 -2.5 0 -2.1 -2.6 02/21/2006 05:10:00 18.3 2 22.9 12.6 18.3 2.1 23.3 12.2 15.3 2.6 22.1 9.9 304 7 307 165 -2.5 0 -2.4 -2.6 02/21/2006 05:20:00 19.5 2.1 24.8 13.7 19.4 2.2 24.8 13.7 16.5 2.4 22.6 11.1 305 8 303 165 -2.4 0 -2.1 -2.6 02/21/2006 05:30:00 19.3 2.3 24.4 12.6 19.2 2.3 24 12.2 17.9 2.4 24.4 11.5 310 6 325 165 -2.4 0 -2.1 -2.6 02/21/2006 05:40:00 18.7 1.9 23.7 13.7 18.7 1.9 23.3 13.3 16.6 2.4 22.9 10.7 307 6 313 165 -2.4 0 -2.1 -2.6 02/21/2006 05:50:00 17.2 1.5 21.8 13.7 17.2 1.6 21.8 13.3 15.9 2 20.6 10.3 311 6 302 165 -2.5 0 -2.4 -2.6 02/21/2006 06:00:00 16.7 1.4 21 13.3 16.6 1.4 21 13 16.4 1.4 20.2 11.5 316 6 314 165 -2.5 0 -2.6 -2.8 02/21/2006 06:10:00 17.3 1.5 21 12.6 17.2 1.5 20.2 12.6 16.4 1.7 20.2 11.5 312 6 313 165 -2.5 0 -2.4 -2.6 02/21/2006 06:20:00 15.1 1.3 19.9 12.2 15 1.3 19.9 11.8 14.3 1.5 18.7 10.3 315 7 310 165 -2.6 0 -2.6 -2.8 02/21/2006 06:30:00 17.5 2.2 22.1 12.2 17.4 2.2 22.1 12.2 15.9 2.4 21.4 10.3 310 6 305 165 -2.6 0.1 -2.4 -2.8 02/21/2006 06:40:00 17.7 1.3 21.4 14.5 17.6 1.3 20.6 14.5 16.4 1.7 20.6 11.5 312 6 316 165 -2.5 0 -2.4 -2.6 02/21/2006 06:50:00 17.4 1.7 21.4 13.3 17.3 1.7 21 13 16.5 2 21.8 11.8 313 6 319 165 -2.6 0 -2.6 -2.8 02/21/2006 07:00:00 18.6 2.2 24 13 18.5 2.3 22.9 12.6 17.2 2.2 22.1 11.5 311 7 313 165 -2.5 0.1 -2.4 -2.8 02/21/2006 07:10:00 16.7 1.8 21.4 11.5 16.6 1.9 21.4 11.5 15.1 1.8 21 10.3 310 8 292 165 -2.5 0 -2.4 -2.6 02/21/2006 07:20:00 16.2 1.6 19.9 12.2 16.1 1.6 19.9 12.2 14.9 2 19.1 9.9 310 7 309 165 -2.5 0 -2.4 -2.6 02/21/2006 07:30:00 15.7 1.3 19.9 11.8 15.6 1.3 19.5 11.8 14.7 1.7 19.5 10.7 313 5 319 165 -2.5 0 -2.4 -2.6 02/21/2006 07:40:00 15.4 1.5 19.9 10.7 15.3 1.5 19.9 11.1 14.7 1.6 19.1 9.5 315 7 317 165 -2.5 0 -2.4 -2.8 02/21/2006 07:50:00 15.9 1.5 19.9 10.3 15.8 1.5 19.9 10.7 15.2 1.3 17.9 10.3 315 6 305 165 -2.5 0.1 -2.4 -2.8 02/21/2006 08:00:00 16 1.5 19.5 12.2 16 1.5 19.5 11.8 14.2 1.7 18.7 10.3 310 7 304 165 -2.5 0 -2.6 -2.6 02/21/2006 08:10:00 15.5 1.7 20.2 10.3 15.4 1.7 19.5 10.3 14.1 2 18.7 9.1 312 8 307 165 -2.5 0 -2.4 -2.8 02/21/2006 08:20:00 15.3 1.7 21 11.5 15.2 1.8 20.6 11.1 14.6 1.7 19.5 11.1 315 6 312 165 -2.6 0 -2.6 -2.8 02/21/2006 08:30:00 17.5 1.4 20.6 14.1 17.3 1.4 20.6 14.1 16.5 1.4 20.2 12.2 314 7 304 165 -2.5 0 -2.4 -2.6 02/21/2006 08:40:00 17.8 1.3 20.6 14.5 17.7 1.3 20.6 14.5 16.9 1.5 21 12.6 313 6 312 165 -2.5 0 -2.1 -2.6 02/21/2006 08:50:00 16.4 1.3 19.5 11.8 16.3 1.3 19.5 12.2 15.6 1.5 20.2 10.7 315 7 310 165 -2.3 0 -2.1 -2.6 02/21/2006 09:00:00 16.1 1.5 19.1 11.8 16 1.5 18.7 11.8 15.5 1.7 19.5 11.1 317 6 312 165 -2.2 0 -2.1 -2.4 02/21/2006 09:10:00 16.5 1.5 20.6 12.2 16.3 1.5 20.2 12.6 16.2 1.5 20.2 12.6 318 5 319 165 -2.1 0 -1.9 -2.1 02/21/2006 09:20:00 16.9 1.7 22.6 12.6 16.7 1.7 22.1 12.2 16.4 1.9 22.6 11.5 319 6 316 165 -2 0.1 -1.7 -2.1 02/21/2006 09:30:00 16.3 1.6 21.8 12.6 16.1 1.5 21 12.6 15.8 1.7 20.6 11.5 318 7 326 165 -1.8 0.1 -1.7 -1.9 02/21/2006 09:40:00 19.1 2.2 24.8 13.3 18.9 2.2 24.4 13.3 18.5 2.2 24 13.3 319 6 319 165 -1.7 0 -1.4 -1.9 02/21/2006 09:50:00 18.3 1.9 22.9 13.3 18.1 1.9 22.6 13.3 17.5 1.9 21.4 11.8 319 8 308 165 -1.6 0 -1.4 -1.7 02/21/2006 10:00:00 17.5 1.7 21.8 13 17.3 1.7 21.4 13.3 17.2 1.7 22.6 12.2 322 7 315 165 -1.5 0 -1.4 -1.7 02/21/2006 10:10:00 16.3 2 21 11.1 16.1 2 21 10.7 16 2.1 20.6 9.9 322 6 310 165 -1.4 0 -1.2 -1.4 02/21/2006 10:20:00 15.9 1.8 20.2 11.8 15.8 1.8 19.9 11.1 15.2 1.8 19.9 9.1 319 9 305 165 -1.3 0 -1.2 -1.4 02/21/2006 10:30:00 16.4 1.8 21.4 12.2 16.3 1.8 21 12.2 15.3 2 19.9 10.7 316 9 305 165 -1.4 0 -1.2 -1.4 02/21/2006 10:40:00 15.2 2 21 10.7 15.1 2 21.4 10.3 14.2 1.8 19.5 8.8 316 9 306 165 -1.3 0 -1.2 -1.4 02/21/2006 10:50:00 15.7 1.7 19.9 11.1 15.5 1.8 19.9 11.1 15.2 1.7 21 10.7 321 10 321 165 -1.3 0 -1.2 -1.4 02/21/2006 11:00:00 17 2.1 22.6 11.8 16.9 2.1 22.1 12.2 16.5 2.4 22.1 9.9 319 8 318 165 -1.3 0 -1.2 -1.4 02/21/2006 11:10:00 17.3 2 21.4 12.6 17.2 2 21.8 11.8 16.5 1.7 20.2 11.8 316 7 325 165 -1.4 0 -1.2 -1.4 02/21/2006 11:20:00 16.7 1.8 22.6 12.2 16.6 1.8 22.1 11.8 16 1.8 20.6 10.3 318 10 300 165 -1.3 0 -1.2 -1.4 02/21/2006 11:30:00 17.2 1.5 21 13.7 17.1 1.5 20.6 13.3 16.6 1.7 22.1 11.5 317 7 318 165 -1.3 0 -1 -1.4 02/21/2006 11:40:00 19 1.7 23.3 13 18.8 1.7 23.3 13.3 18.5 1.7 22.9 12.6 317 6 316 165 -1.1 0 -1 -1.2 02/21/2006 11:50:00 16.9 1.5 20.6 12.6 16.7 1.5 20.6 12.6 16.1 1.7 21 9.9 315 5 323 165 -1 0 -0.8 -1.2 02/21/2006 12:00:00 17.2 1.7 21.4 12.6 17 1.7 21.4 12.2 16.7 1.9 21.8 11.5 321 8 320 165 -0.9 0 -0.8 -1.2 02/21/2006 12:10:00 17.1 1.7 21.8 12.6 16.9 1.7 21 12.2 16.5 1.6 20.2 11.5 319 8 307 165 -0.9 0 -0.8 -1.2 02/21/2006 12:20:00 17 1.9 22.9 10.3 16.8 1.9 22.9 10.3 16.2 2.2 22.6 10.7 317 8 314 165 -0.9 0 -0.8 -1 02/21/2006 12:30:00 15 1.7 19.1 10.3 14.8 1.6 18.7 10.3 14.4 1.9 18.7 6.5 323 9 330 165 -0.5 0.1 -0.3 -0.8 02/21/2006 12:40:00 13.1 1.7 16.8 8 12.9 1.6 16.4 8.4 12.6 1.7 16.1 8 320 8 315 165 -0.4 0 -0.3 -0.5 02/21/2006 12:50:00 13.1 1.3 16.1 9.1 12.9 1.2 15.6 9.1 12.6 1.2 15.3 8.8 321 8 317 165 -0.3 0 -0.1 -0.5 02/21/2006 13:00:00 13.7 1.6 17.2 9.1 13.5 1.6 16.8 9.1 13.1 1.8 16.4 8.8 316 6 313 165 -0.4 0 -0.3 -0.5 02/21/2006 13:10:00 13.9 1.5 17.2 9.9 13.8 1.5 17.2 9.9 12.6 1.4 16.1 9.9 314 8 305 165 -0.4 0 -0.3 -0.8 02/21/2006 13:20:00 14.6 1 17.2 11.1 14.5 1 16.8 11.1 12.4 1.7 16.8 8 309 5 301 165 -0.6 0 -0.5 -0.8 02/21/2006 13:30:00 15.5 1.3 19.1 12.6 15.3 1.3 19.1 12.6 14.6 2.1 19.5 9.1 315 7 317 165 -0.5 0 -0.3 -0.5 02/21/2006 13:40:00 15.8 1.5 19.9 12.2 15.6 1.5 19.9 12.2 15.3 1.7 20.2 11.1 320 7 323 165 -0.3 0 -0.1 -0.8 02/21/2006 13:50:00 17 1.4 20.2 13.3 16.9 1.4 20.2 13 16.1 1.7 20.6 10.3 315 7 318 165 -0.4 0 -0.3 -0.5 02/21/2006 14:00:00 17.3 1.2 19.9 14.1 17.2 1.3 19.9 14.1 16.9 1.5 20.6 11.1 318 7 317 165 -0.4 0 -0.3 -0.5 02/21/2006 14:10:00 16.9 1.3 21 14.1 16.8 1.3 21 13.7 16.7 1.6 21 13 319 5 319 165 -0.3 0 -0.3 -0.5 02/21/2006 14:20:00 16.7 1.3 19.9 12.2 16.6 1.4 20.2 12.6 16 1.9 20.6 10.7 315 6 313 165 -0.5 0 -0.3 -0.5 02/21/2006 14:30:00 16.4 0.9 18.7 14.1 16.3 0.9 18.7 14.1 15.4 1.1 17.9 13 314 5 315 165 -0.5 0 -0.3 -0.5 02/21/2006 14:40:00 16.4 1.1 19.5 13.3 16.3 1.1 19.1 13.3 15.5 1.5 19.1 10.7 315 7 311 165 -0.5 0 -0.3 -0.5 02/21/2006 14:50:00 17.7 1.3 20.6 14.5 17.6 1.3 20.6 14.1 17.4 1.3 20.2 14.1 317 5 310 165 -0.6 0 -0.5 -0.8 02/21/2006 15:00:00 18.2 1.1 21.4 14.9 18.1 1.2 20.6 14.9 17.4 1.5 21 13.3 314 4 310 165 -0.6 0 -0.5 -0.8 02/21/2006 15:10:00 18.7 1.2 21 14.5 18.6 1.1 20.6 14.9 18 1.3 21 13.7 315 4 323 165 -0.8 0 -0.5 -0.8 02/21/2006 15:20:00 19.3 1 21.8 16.1 19.2 1.1 22.1 15.6 18.6 1.3 22.1 15.3 314 4 316 165 -0.8 0 -0.8 -1 02/21/2006 15:30:00 18.2 1.3 21.4 14.1 18.1 1.3 21.4 14.1 17.2 1.7 20.2 9.9 312 5 310 165 -0.8 0 -0.8 -0.8 02/21/2006 15:40:00 18.7 1.3 22.1 15.3 18.6 1.3 21.8 14.9 17.6 1.4 20.2 13.3 313 5 310 165 -0.8 0 -0.5 -0.8 02/21/2006 15:50:00 19.6 1.1 22.6 16.4 19.5 1.2 22.1 15.6 18.8 1.5 21.8 14.9 314 5 310 165 -0.8 0 -0.5 -0.8 02/21/2006 16:00:00 18 1.2 20.6 14.9 17.9 1.2 21 14.5 17.6 1.3 22.1 14.1 316 5 309 165 -0.7 0 -0.5 -0.8 02/21/2006 16:10:00 17.7 1.3 20.6 13 17.6 1.3 20.6 13 16.7 1.5 20.2 11.8 315 7 304 165 -0.7 0 -0.5 -0.8 02/21/2006 16:20:00 18 1.5 21.8 13.3 17.9 1.5 21.8 12.6 17.7 1.5 21.4 13.3 320 7 310 165 -0.7 0 -0.5 -0.8 02/21/2006 16:30:00 18.8 1.5 22.1 14.5 18.6 1.5 21.8 14.5 18.3 1.6 21.8 13.3 318 7 312 165 -0.8 0 -0.5 -0.8 02/21/2006 16:40:00 18.4 1.5 21.4 14.1 18.3 1.5 21.4 13.3 17.8 1.8 21.4 11.8 316 6 314 165 -0.9 0 -0.8 -0.8 02/21/2006 16:50:00 16.9 1.7 21.4 13.7 16.8 1.7 21 13 16.1 1.9 21.8 11.5 316 6 325 165 -0.9 0 -0.8 -1 02/21/2006 17:00:00 17.8 1.3 21.4 14.5 17.7 1.3 21 14.1 17 1.7 21.4 12.2 314 6 319 165 -0.9 0 -0.8 -1 02/21/2006 17:10:00 17.9 1.5 21 14.1 17.7 1.5 21 13.3 17.3 1.5 20.2 11.5 315 5 313 165 -0.9 0 -0.8 -1 02/21/2006 17:20:00 17.8 1.4 21 14.1 17.7 1.5 21 13.3 17.1 1.7 21 12.6 314 5 313 165 -1 0 -0.8 -1.2 02/21/2006 17:30:00 17 1.2 19.9 14.1 16.8 1.2 19.5 13.7 16.1 1.4 19.9 12.2 316 6 312 165 -1.2 0 -1 -1.2 02/21/2006 17:40:00 16.5 1.2 19.5 13.7 16.4 1.2 19.5 13.3 15.6 1.5 19.1 12.2 315 5 310 165 -1.3 0 -1.2 -1.4 02/21/2006 17:50:00 15.6 1.1 18.3 11.5 15.5 1.1 17.9 11.8 14.8 1.3 17.6 10.3 314 6 312 165 -1.5 0 -1.2 -1.7 02/21/2006 18:00:00 15.4 1.1 17.9 13 15.3 1.1 17.9 12.6 14.5 1 17.2 12.2 314 5 311 165 -1.7 0 -1.4 -1.9 02/21/2006 18:10:00 15.8 1.1 18.3 13 15.6 1.1 18.3 13 14.9 1.5 17.9 11.1 314 5 307 165 -1.6 0 -1.4 -1.9 02/21/2006 18:20:00 15.9 1.1 18.7 12.2 15.8 1.2 18.7 12.2 15.2 1.3 17.9 11.1 315 5 319 165 -1.6 0 -1.4 -1.7 02/21/2006 18:30:00 16.6 1.1 19.1 12.2 16.5 1.1 19.1 12.2 15.6 1.2 17.9 11.8 314 4 307 165 -1.5 0 -1.4 -1.7 02/21/2006 18:40:00 15.5 1 17.6 12.6 15.4 1 17.6 12.6 14.8 1.1 17.2 10.7 314 5 307 165 -1.6 0 -1.4 -1.7 02/21/2006 18:50:00 14.6 1.1 16.8 11.8 14.4 1.1 16.8 11.5 12.9 1.2 15.6 9.9 311 5 308 165 -1.7 0 -1.4 -1.9 02/21/2006 19:00:00 14.8 0.9 17.6 12.6 14.7 1 17.2 12.6 13.4 1.1 16.1 9.9 312 4 312 165 -1.8 0 -1.7 -1.9 02/21/2006 19:10:00 13.7 1.2 16.8 10.3 13.6 1.2 16.8 10.3 12.2 1.3 15.3 8.8 311 5 310 165 -2 0 -1.9 -2.1 02/21/2006 19:20:00 12.5 1 15.6 10.3 12.4 1 15.6 10.3 11.6 1 14.1 8 314 6 308 165 -2 0 -1.9 -2.1 02/21/2006 19:30:00 10.9 1 13.7 7.6 10.8 1 13.7 7.6 10.1 1.1 13 7.2 316 6 317 165 -2 0 -1.9 -2.1 02/21/2006 19:40:00 10.3 1 12.6 8 10.2 1 12.2 7.2 9.2 0.9 11.5 6.8 311 6 307 165 -2 0 -1.9 -2.1 02/21/2006 19:50:00 11.6 1 14.1 9.1 11.5 1 13.7 8.8 9.6 1 11.8 7.2 308 5 300 165 -2.1 0 -1.9 -2.1 02/21/2006 20:00:00 11.9 0.8 14.1 9.9 11.8 0.8 14.5 9.5 9.4 1.1 11.8 6.8 306 4 301 165 -2.1 0 -1.9 -2.1 02/21/2006 20:10:00 10.3 0.8 12.2 8 10.1 0.8 12.2 8 8.6 1 11.1 6.1 309 5 305 165 -2.1 0 -1.9 -2.1 02/21/2006 20:20:00 9.9 0.8 11.8 8 9.9 0.8 11.8 8 8.2 0.9 10.3 6.1 308 4 302 165 -2.2 0 -2.1 -2.4 02/21/2006 20:30:00 9.3 0.8 11.1 7.2 9.2 0.8 11.1 7.2 8.1 0.8 9.9 5.3 310 6 305 165 -2.2 0 -2.1 -2.4 02/21/2006 20:40:00 10.1 0.8 12.2 8 10 0.8 12.2 8 9.4 0.8 11.8 7.6 313 4 304 165 -2.3 0 -2.1 -2.6 02/21/2006 20:50:00 11.2 0.7 13 8.8 11.1 0.7 13 8.8 10.1 1.1 12.6 6.8 311 4 318 165 -2.1 0 -1.9 -2.4 02/21/2006 21:00:00 10.8 0.9 13 8.8 10.6 0.9 13 8.4 9.7 0.9 11.8 7.2 312 5 308 165 -2.1 0 -1.9 -2.4 02/21/2006 21:10:00 9.8 0.9 11.8 7.2 9.6 0.9 11.8 7.2 9.3 0.9 11.8 6.8 316 6 315 165 -2.3 0 -2.1 -2.6 02/21/2006 21:20:00 9.7 0.7 11.8 7.6 9.5 0.7 11.5 7.6 9.6 0.9 12.2 7.2 319 5 325 165 -2.3 0 -2.1 -2.6 02/21/2006 21:30:00 9.1 1 11.1 6.8 9 1 11.1 6.8 8.6 1 10.7 5.3 315 5 307 165 -2.4 0 -2.1 -2.6 02/21/2006 21:40:00 7.5 1.2 10.7 4.9 7.5 1.1 10.7 4.9 6.8 1.2 10.7 3.8 316 7 308 165 -2.6 0 -2.4 -2.8 02/21/2006 21:50:00 8 0.9 10.3 5.7 7.9 0.8 9.9 5.7 7.3 1 9.9 4.6 314 7 302 165 -2.2 0 -2.1 -2.4 02/21/2006 22:00:00 8.1 0.8 10.3 5.7 8 0.8 9.9 6.5 7.5 0.8 10.3 5.7 315 6 298 165 -2.5 0 -2.1 -2.6 02/21/2006 22:10:00 9 0.9 10.7 5.3 8.8 0.9 10.7 5.7 7.9 1 10.3 4.9 311 5 313 165 -2.4 0 -2.1 -2.6 02/21/2006 22:20:00 7.9 1 10.3 5.3 7.8 1 10.3 5.3 7 0.9 9.1 4.6 311 5 309 165 -2.5 0 -2.4 -2.8 02/21/2006 22:30:00 6.9 0.7 8.4 4.9 6.8 0.7 8.4 4.9 6.2 0.9 8.8 3.8 312 7 326 165 -2.6 0 -2.6 -2.8 02/21/2006 22:40:00 5.9 0.6 7.6 3.8 5.8 0.6 7.2 4.2 5.7 0.6 6.8 3.8 318 6 321 165 -2.8 0 -2.6 -3 02/21/2006 22:50:00 6.2 0.6 8 4.9 6.2 0.6 7.6 4.9 5.7 0.7 8 3.8 313 7 315 165 -2.8 0 -2.6 -3 02/21/2006 23:00:00 6.6 0.6 8 4.9 6.5 0.6 8.4 4.9 5.9 0.7 7.6 3.8 312 6 306 165 -2.9 0.1 -2.8 -3 02/21/2006 23:10:00 6.2 0.8 8 4.2 6.1 0.8 8 3.8 5.4 0.9 7.6 3.4 308 6 321 165 -3 0 -2.8 -3.3 02/21/2006 23:20:00 5.2 1 7.2 2.6 5.1 1 7.6 2.6 4.3 0.9 6.8 2.3 308 7 300 165 -3.1 0 -2.8 -3.3 02/21/2006 23:30:00 5.1 0.8 7.2 3 5.1 0.8 7.2 3 4.1 0.8 6.1 1.9 304 8 297 165 -3.3 0 -3 -3.5 02/21/2006 23:40:00 3.8 0.6 5.3 2.3 3.7 0.6 5.3 2.3 3.3 0.7 5.3 1.9 308 8 312 165 -3.3 0 -3 -3.5 02/21/2006 23:50:00 4.9 0.8 6.8 3 4.8 0.8 6.8 3 4.7 0.8 6.8 3 324 10 334 165 -2.9 0 -2.6 -3.3 02/22/2006 00:00:00 4.6 0.6 6.1 3 4.5 0.6 6.1 3 4.6 0.5 6.1 3 326 9 328 165 -2.8 0 -2.6 -2.8 02/22/2006 00:10:00 5.1 0.7 7.2 3.4 5.1 0.7 7.2 3 5.2 0.6 6.8 3.8 326 8 319 165 -2.7 0 -2.6 -3 02/22/2006 00:20:00 4.7 0.5 6.1 3.4 4.6 0.5 5.7 3.4 4.8 0.5 6.1 3 331 8 313 165 -3 0 -2.8 -3 02/22/2006 00:30:00 5.3 0.6 6.8 3.8 5.2 0.6 6.8 3.4 5.2 0.6 8 3 324 9 316 165 -3 0 -2.8 -3 02/22/2006 00:40:00 5.9 0.7 8 4.6 5.7 0.7 7.6 3.8 5.6 0.6 7.2 4.2 316 6 315 165 -3 0.1 -2.8 -3.3 02/22/2006 00:50:00 6.1 0.6 8 4.9 6 0.6 7.6 4.9 5.9 0.6 7.6 4.6 318 6 321 165 -3.1 0 -2.8 -3.3 02/22/2006 01:00:00 6.7 0.6 8.4 5.3 6.6 0.6 8.4 5.3 5.9 0.6 7.2 3.4 310 6 310 165 -3.1 0 -3 -3.3 02/22/2006 01:10:00 7.1 0.7 8.8 4.9 7 0.7 8.8 5.3 6.4 0.7 8.4 4.2 311 5 309 165 -3 0 -2.8 -3.3 02/22/2006 01:20:00 6.6 0.9 9.9 4.6 6.5 0.9 9.9 4.6 6 0.9 9.5 3.8 313 7 321 165 -3 0 -2.8 -3.3 02/22/2006 01:30:00 7.6 1.1 10.3 5.3 7.5 1.1 10.3 4.9 6.9 1.2 10.3 4.6 316 7 312 165 -2.8 0.2 -2.6 -3 02/22/2006 01:40:00 7 0.8 8.8 4.6 6.9 0.8 9.1 4.6 6.2 0.9 8.8 3.8 313 9 330 165 -2.5 0 -2.4 -2.8 02/22/2006 01:50:00 7.8 1.2 11.1 4.9 7.7 1.1 10.7 4.9 6.2 1.1 9.5 3.8 303 7 320 165 -2.6 0.1 -2.4 -2.8 02/22/2006 02:00:00 9.1 0.8 11.8 6.8 9 0.8 11.5 6.8 8 1.2 10.3 4.6 310 5 306 165 -2.5 0 -2.6 -2.6 02/22/2006 02:10:00 8 0.9 10.3 5.7 7.8 0.8 9.9 5.7 7.5 0.9 9.5 5.3 315 4 319 165 -2.8 0 -2.6 -3 02/22/2006 02:20:00 7.5 0.7 9.5 5.3 7.4 0.7 9.1 4.9 6.8 0.8 9.1 4.6 313 6 305 165 -3 0 -2.8 -3.3 02/22/2006 02:30:00 8 0.8 9.9 6.1 8 0.8 9.9 6.1 6.7 1 10.3 4.2 308 6 305 165 -3 0 -2.8 -3 02/22/2006 02:40:00 8.3 0.8 10.3 6.1 8.2 0.8 9.9 6.1 6.8 1 9.5 4.6 305 5 309 165 -3 0 -2.8 -3 02/22/2006 02:50:00 8.2 1 10.3 5.3 8.2 0.9 10.3 5.3 7.1 1.1 9.5 4.2 307 6 308 165 -3.1 0 -2.8 -3.3 02/22/2006 03:00:00 8.9 0.9 10.7 6.1 8.8 0.9 11.1 6.1 7.8 1 11.1 4.9 310 5 310 165 -3 0 -2.8 -3 02/22/2006 03:10:00 9.8 0.9 11.5 7.6 9.6 0.9 11.5 7.2 8.2 1.1 11.1 5.7 308 5 305 165 -2.9 0 -2.8 -3 02/22/2006 03:20:00 10.7 1 12.6 8 10.6 1 12.6 8 9.2 1.1 11.5 5.7 308 4 311 165 -2.8 0 -2.6 -3 02/22/2006 03:30:00 10.3 0.9 12.6 7.6 10.1 0.8 12.2 7.6 8.4 0.9 10.7 6.1 306 5 308 165 -2.8 0 -2.6 -2.8 02/22/2006 03:40:00 11.1 1 13.3 8.8 10.9 1 13.3 8.4 9 1.1 12.6 6.1 306 4 301 165 -2.8 0 -2.6 -2.8 02/22/2006 03:50:00 11.7 1 13.7 9.1 11.5 1 13.3 8.8 9.2 1.1 12.2 6.1 305 5 307 165 -2.8 0 -2.6 -2.8 02/22/2006 04:00:00 13 1 14.9 9.9 12.8 1 14.9 9.9 10.7 1.2 14.5 6.8 307 5 317 165 -2.7 0 -2.6 -2.8 02/22/2006 04:10:00 13.4 1 15.3 10.7 13.2 1 15.3 10.7 11.3 1.2 15.3 7.6 307 5 300 165 -2.5 0 -2.1 -2.6 02/22/2006 04:20:00 13.2 1.3 16.1 9.1 13 1.3 15.6 9.5 10.9 1.2 14.5 7.2 307 5 305 165 -2.6 0 -2.6 -2.8 02/22/2006 04:30:00 14.1 1 16.1 10.3 14 1 16.1 10.3 11 1 14.1 7.2 307 3 304 165 -2.7 0 -2.6 -2.8 02/22/2006 04:40:00 14.1 0.6 15.6 11.8 14 0.6 15.3 11.5 11 1 13.3 8 307 2 307 165 -2.8 0 -2.6 -2.8 02/22/2006 04:50:00 13.4 0.8 15.3 9.9 13.3 0.8 14.9 9.9 11 1.3 14.1 7.6 307 4 307 165 -2.8 0 -2.6 -3 02/22/2006 05:00:00 13.5 1 15.3 11.1 13.4 1 15.6 11.1 10.3 1.4 14.1 7.2 306 4 307 165 -2.8 0 -2.6 -2.8 02/22/2006 05:10:00 12.6 0.8 14.5 10.3 12.5 0.8 14.1 9.9 10 1 12.6 7.2 307 4 308 165 -2.8 0 -2.6 -3 02/22/2006 05:20:00 11.7 0.8 13.7 9.1 11.6 0.8 13.7 9.5 10.2 1.3 13.3 6.5 309 4 307 165 -2.8 0 -2.6 -2.8 02/22/2006 05:30:00 11.9 0.9 14.9 9.9 11.8 0.9 14.9 9.5 10.6 1.2 13 7.6 311 5 311 165 -2.9 0 -2.8 -3 02/22/2006 05:40:00 12.9 1 14.9 9.9 12.8 1 15.3 9.9 11.1 1.2 14.5 8.4 309 4 307 165 -2.8 0 -2.6 -3 02/22/2006 05:50:00 13.5 1.1 16.4 9.5 13.4 1.1 16.4 9.5 11.9 1.3 14.9 8.8 310 5 295 165 -2.6 0 -2.6 -2.8 02/22/2006 06:00:00 14.1 0.9 16.1 11.1 14 0.9 16.1 11.5 12.1 1.3 14.5 8 310 4 309 165 -2.4 0 -2.1 -2.6 02/22/2006 06:10:00 13.2 1 15.3 9.9 13.1 0.9 14.9 9.5 11.3 1 13.7 9.1 309 3 307 165 -2.4 0 -2.1 -2.6 02/22/2006 06:20:00 13.4 1.2 16.1 10.3 13.2 1.2 16.1 9.9 11.1 1.3 14.5 7.6 308 4 309 165 -2.5 0 -2.4 -2.6 02/22/2006 06:30:00 13.5 1 15.3 11.1 13.4 1 14.9 11.1 11.3 1.1 14.1 8.8 309 4 315 165 -2.4 0 -2.1 -2.6 02/22/2006 06:40:00 13 1 15.3 9.5 12.9 1 15.3 9.5 10.8 1.2 13.3 7.2 307 4 309 165 -2.5 0 -2.4 -2.6 02/22/2006 06:50:00 12.3 1.2 15.3 8.4 12.2 1.2 15.3 8.4 10.1 1.4 16.1 7.2 308 5 323 165 -2.5 0 -2.1 -2.6 02/22/2006 07:00:00 12 1 14.1 9.1 11.9 1 13.7 8.8 9.5 1.2 12.6 7.2 307 4 301 165 -2.4 0 -2.1 -2.6 02/22/2006 07:10:00 12 1 13.7 9.1 11.9 0.9 13.7 9.1 10.1 1.1 12.6 6.5 309 4 310 165 -2.5 0 -2.4 -2.6 02/22/2006 07:20:00 11.7 0.7 14.1 9.9 11.6 0.7 14.1 9.5 10.2 1 12.6 7.6 311 3 307 165 -2.4 0 -2.1 -2.6 02/22/2006 07:30:00 11 0.8 13 8.8 10.9 0.8 13 8.8 9.6 1.2 12.6 6.5 311 5 308 165 -2.4 0 -2.1 -2.6 02/22/2006 07:40:00 12.1 0.8 14.1 9.9 12 0.8 13.7 9.9 10 1.2 13.3 7.2 308 3 307 165 -2.4 0 -2.1 -2.6 02/22/2006 07:50:00 12.1 0.9 14.5 9.1 12 0.9 14.5 9.5 9.6 1.2 13 6.5 306 4 307 165 -2.4 0 -2.1 -2.6 02/22/2006 08:00:00 11.1 1.3 14.1 7.2 11.1 1.3 13.7 7.2 8.7 1.3 11.8 5.3 304 5 304 165 -2.5 0 -2.1 -2.6 02/22/2006 08:10:00 10.4 0.7 12.2 8.4 10.3 0.7 12.6 8.4 7.6 0.9 10.7 5.7 300 5 313 165 -2.6 0 -2.4 -2.8 02/22/2006 08:20:00 10.7 0.8 12.6 8.8 10.7 0.8 12.6 8.8 7.6 0.8 10.7 5.7 299 4 301 165 -2.5 0 -2.4 -2.8 02/22/2006 08:30:00 11 0.6 12.6 9.1 11.1 0.7 12.6 9.1 8.4 1.1 11.1 6.5 296 4 292 165 -2.5 0 -2.4 -2.6 02/22/2006 08:40:00 10.9 0.9 13 8.4 10.9 0.9 13.3 8 8.2 1.1 11.1 5.7 299 6 299 165 -2.5 0 -2.4 -2.6 02/22/2006 08:50:00 11.3 0.9 14.1 9.1 11.2 0.9 13.7 8.8 9 1.4 13 6.1 305 6 308 165 -2.4 0 -2.1 -2.6 02/22/2006 09:00:00 11.7 1 14.9 9.1 11.6 0.9 14.5 9.1 9.1 1.3 13 6.8 305 4 303 165 -2.2 0 -2.1 -2.4 02/22/2006 09:10:00 10.7 0.8 13 8.4 10.6 0.8 12.6 8.4 7.8 0.9 10.7 5.7 298 5 304 165 -2.2 0 -2.1 -2.4 02/22/2006 09:20:00 10.4 0.7 13 8.8 10.4 0.7 12.2 8.8 8.2 1 10.7 6.1 296 5 300 165 -2.1 0 -1.9 -2.4 02/22/2006 09:30:00 10.6 0.6 12.2 9.1 10.6 0.6 12.6 9.1 8.3 1.1 11.8 6.1 295 5 291 165 -2.1 0 -1.9 -2.1 02/22/2006 09:40:00 10.7 0.6 12.2 8.8 10.7 0.7 12.2 8.8 8.3 1 11.5 6.1 296 3 299 165 -2.1 0 -1.9 -2.1 02/22/2006 09:50:00 10.6 0.7 12.2 8 10.6 0.7 12.2 8.4 7.7 0.9 10.3 5.7 299 4 298 165 -2 0 -1.9 -2.1 02/22/2006 10:00:00 9.9 0.6 11.5 8 9.8 0.7 11.5 8 7.1 0.7 9.5 5.7 300 5 301 165 -2 0 -1.9 -2.1 02/22/2006 10:10:00 9.8 0.8 11.8 7.2 9.7 0.8 11.8 7.2 7.2 0.9 9.9 4.6 300 6 303 165 -1.9 0 -1.7 -2.1 02/22/2006 10:20:00 9.6 0.8 11.1 7.2 9.6 0.8 11.1 7.2 7.1 0.8 9.5 4.6 298 4 304 165 -1.9 0 -1.7 -2.1 02/22/2006 10:30:00 9.6 0.7 11.1 7.6 9.6 0.7 11.1 7.6 7.1 0.8 9.5 4.9 298 4 300 165 -2 0 -1.9 -2.1 02/22/2006 10:40:00 9.1 0.7 10.7 7.6 9.1 0.7 10.7 7.6 6.7 0.8 9.1 5.3 299 5 297 165 -2 0 -1.9 -2.1 02/22/2006 10:50:00 9 0.7 11.1 7.2 9 0.7 10.7 7.2 7.1 0.9 10.3 5.3 295 5 298 165 -2.1 0 -1.9 -2.1 02/22/2006 11:00:00 9.7 0.7 11.5 7.2 9.7 0.8 11.8 7.2 7.4 0.8 9.9 5.3 297 4 296 165 -2.1 0 -1.9 -2.1 02/22/2006 11:10:00 10.2 0.7 11.8 8 10.2 0.7 11.8 7.2 8.4 1.1 11.8 5.7 293 5 283 165 -2 0 -1.9 -2.1 02/22/2006 11:20:00 8.7 0.7 10.3 6.8 8.7 0.7 10.3 6.8 6.6 0.8 8.8 4.6 295 4 294 165 -1.9 0 -1.7 -2.1 02/22/2006 11:30:00 9.3 0.8 11.5 7.2 9.3 0.9 11.5 7.2 7.4 1.2 11.1 4.9 295 6 287 165 -1.6 0 -1.4 -1.9 02/22/2006 11:40:00 8.8 1.1 12.2 6.1 8.7 1.1 12.2 6.1 6.9 1.2 9.9 4.6 297 6 303 165 -1.5 0 -1.4 -1.7 02/22/2006 11:50:00 8.7 1 10.7 6.8 8.7 1 11.1 6.5 6.8 1 9.9 4.6 302 7 297 165 -1.3 0 -1.2 -1.4 02/22/2006 12:00:00 8.8 0.9 11.1 6.5 8.8 1 11.5 6.5 7.1 1.1 10.7 4.2 297 7 296 165 -1.3 0 -1.2 -1.4 02/22/2006 12:10:00 9.9 0.8 11.8 7.2 9.9 0.8 11.5 7.2 8.1 1.3 11.8 4.9 295 8 284 165 -1.2 0 -1 -1.2 02/22/2006 12:20:00 10.1 0.9 11.8 8 10.1 0.9 12.2 8 7.9 1.1 10.7 5.3 300 6 293 165 -1 0 -0.8 -1.2 02/22/2006 12:30:00 9.7 1 12.2 6.8 9.6 1 12.2 6.8 7.6 1 11.1 5.3 304 7 306 165 -0.9 0 -0.8 -1.2 02/22/2006 12:40:00 9.5 1.1 11.8 6.1 9.4 1.1 11.8 6.1 7.8 1.1 11.5 4.9 306 7 302 165 -0.8 0 -0.5 -1 02/22/2006 12:50:00 9.2 0.9 11.5 6.8 9.1 0.9 11.1 6.8 7.8 1.1 10.7 5.3 304 7 307 165 -0.6 0 -0.5 -0.8 02/22/2006 13:00:00 9.8 1 12.2 6.8 9.7 1 12.2 7.2 8.2 1.2 10.7 4.9 307 7 304 165 -0.6 0 -0.5 -0.8 02/22/2006 13:10:00 9 1 13 6.5 8.9 1 12.6 6.8 8.4 1.3 12.2 5.3 314 8 313 165 -0.5 0.1 -0.3 -0.8 02/22/2006 13:20:00 11.5 1.1 13.7 8.8 11.4 1.2 13.3 8.4 9.5 1.3 13 6.5 307 6 300 165 -0.5 0 -0.3 -0.8 02/22/2006 13:30:00 11.3 1 13.7 8.4 11.1 1 13.3 8.8 9.3 1.1 11.8 6.5 308 5 302 165 -0.6 0 -0.5 -0.8 02/22/2006 13:40:00 11.3 1 14.1 8.8 11.2 1 13.7 8.8 9.5 1.3 12.6 5.7 308 6 307 165 -0.6 0 -0.5 -0.8 02/22/2006 13:50:00 11.7 1.1 14.1 8.8 11.6 1.1 14.1 8.4 9.3 1.3 12.2 6.5 306 5 302 165 -0.6 0 -0.5 -0.8 02/22/2006 14:00:00 11.7 1.2 14.9 8 11.6 1.2 14.5 8 9.5 1.4 13.3 6.1 307 5 309 165 -0.5 0 -0.3 -0.5 02/22/2006 14:10:00 10.9 1.1 13.7 8.4 10.9 1.1 13.3 8.4 8.4 1.1 12.2 5.3 303 6 307 165 -0.3 0 -0.3 -0.5 02/22/2006 14:20:00 9.1 1.1 11.5 6.5 9 1 11.1 6.5 7.5 1.1 10.7 4.9 306 7 291 165 -0.3 0 -0.1 -0.5 02/22/2006 14:30:00 9.7 1.2 12.6 6.8 9.6 1.2 12.6 6.8 8.1 1.4 11.5 4.6 306 8 297 165 -0.3 0 -0.1 -0.5 02/22/2006 14:40:00 11.1 1 13.7 8 11 1 13.3 8.4 8.6 1.3 11.8 5.7 302 6 301 165 -0.3 0 -0.3 -0.5 02/22/2006 14:50:00 12.5 1.1 14.5 8.8 12.5 1.1 14.5 8.8 9.4 1.1 13 6.8 305 6 298 165 -0.3 0 -0.3 -0.5 02/22/2006 15:00:00 11.3 1 13.3 8.8 11.3 1 13.3 8.4 8.6 1.1 12.2 5.7 301 6 297 165 -0.3 0 -0.3 -0.5 02/22/2006 15:10:00 11.8 1.3 14.1 8 11.7 1.3 14.5 8 8.8 1.1 12.2 6.1 302 5 294 165 -0.3 0 -0.3 -0.5 02/22/2006 15:20:00 12.2 1.2 14.9 8.8 12.1 1.2 14.9 8.8 9.6 1.4 13 7.2 306 5 297 165 -0.3 0 -0.3 -0.5 02/22/2006 15:30:00 10.4 1.2 14.9 7.6 10.3 1.3 14.9 6.8 8.6 1.5 12.2 5.7 302 7 297 165 -0.3 0 -0.3 -0.5 02/22/2006 15:40:00 10.4 1 14.9 8 10.4 1 14.1 8 8.9 1.7 13.3 5.7 302 10 308 165 -0.5 0 -0.3 -0.5 02/22/2006 15:50:00 10.4 1.2 13.3 7.2 10.3 1.2 13 6.8 8.8 1.4 13.7 5.7 307 8 309 165 -0.4 0 -0.3 -0.5 02/22/2006 16:00:00 12.4 1.2 15.3 8.8 12.4 1.2 15.6 9.1 10 1.3 14.1 7.2 304 7 296 165 -0.5 0 -0.3 -0.5 02/22/2006 16:10:00 13.5 1.1 16.1 9.9 13.4 1.1 16.1 10.3 10.1 1.2 13.7 6.5 300 5 296 165 -0.6 0 -0.5 -0.8 02/22/2006 16:20:00 12.7 1 15.3 8.8 12.6 1 15.6 8.8 9.6 1.1 13 6.8 301 6 297 165 -0.7 0 -0.5 -0.8 02/22/2006 16:30:00 12.2 1.1 15.3 9.5 12.1 1.1 14.9 9.1 8.9 1.1 14.1 6.5 302 5 310 165 -0.8 0 -0.5 -0.8 02/22/2006 16:40:00 11.2 1.3 14.1 7.2 11.1 1.3 14.1 7.6 8.6 1.2 11.8 5.7 301 6 304 165 -0.8 0 -0.5 -0.8 02/22/2006 16:50:00 11.4 0.9 13.7 8.8 11.3 0.9 13.7 8.4 8.7 1.2 13.7 6.1 305 6 305 165 -0.8 0 -0.5 -0.8 02/22/2006 17:00:00 10.8 1.2 14.9 7.6 10.8 1.2 14.9 8 9.1 1.1 12.2 6.5 307 8 304 165 -0.8 0 -0.8 -0.8 02/22/2006 17:10:00 10.9 1 13.7 8 10.8 1.1 13.7 7.6 9.7 1.3 13.3 6.5 309 6 305 165 -1 0 -0.8 -1.2 02/22/2006 17:20:00 12 1.1 14.9 9.5 12 1.1 14.9 9.1 10.1 1.5 14.9 6.8 307 6 301 165 -1 0 -1 -1.2 02/22/2006 17:30:00 12.1 0.9 14.5 9.9 12 0.9 14.5 9.9 10.7 1.1 13.7 7.6 310 4 316 165 -1.3 0.1 -1 -1.4 02/22/2006 17:40:00 11.3 1 14.1 8.8 11.2 1 14.1 8.8 9.8 1 12.2 7.2 310 5 305 165 -1.4 0 -1.2 -1.4 02/22/2006 17:50:00 11 1 13.3 7.6 10.9 1 13 7.6 10.4 1 12.6 6.5 315 6 310 165 -1.5 0 -1.4 -1.7 02/22/2006 18:00:00 10.2 0.8 12.6 7.6 10.1 0.9 12.2 7.6 9.9 1 12.6 6.5 318 6 310 165 -1.7 0 -1.4 -1.9 02/22/2006 18:10:00 9.7 0.9 11.8 7.2 9.6 0.9 11.8 7.2 9.4 0.9 11.5 6.8 320 6 323 165 -1.7 0 -1.4 -1.9 02/22/2006 18:20:00 9 1 11.1 6.1 8.8 1 11.1 5.7 8.6 1 11.1 5.3 320 8 321 165 -1.8 0 -1.7 -1.9 02/22/2006 18:30:00 9.7 1.3 13.3 7.2 9.6 1.3 13 6.8 9 1.2 12.6 6.5 315 7 302 165 -1.9 0 -1.7 -2.1 02/22/2006 18:40:00 9.2 1.5 11.8 4.9 9.1 1.4 12.2 5.3 8.1 1.3 12.2 4.9 312 10 300 165 -1.9 0 -1.7 -2.1 02/22/2006 18:50:00 9.4 1.3 14.1 5.7 9.3 1.3 14.1 5.7 8.2 1.4 12.2 4.9 310 9 316 165 -2 0 -1.7 -2.1 02/22/2006 19:00:00 9.2 1.9 15.6 3 9.1 1.9 16.1 3.4 7.4 1.8 14.1 3 305 10 299 165 -2 0 -1.9 -2.1 02/22/2006 19:10:00 9.3 1.8 13.7 4.6 9.1 1.8 13.3 3.8 7.6 1.7 12.6 2.6 304 9 307 165 -1.9 0 -1.7 -1.9 02/22/2006 19:20:00 8.9 1.3 12.6 5.7 8.8 1.3 13 5.7 7.4 1.6 11.5 3.8 302 11 290 165 -1.9 0 -1.7 -1.9 02/22/2006 19:30:00 8.8 1.6 14.1 5.7 8.7 1.5 14.1 5.7 7.1 1.6 11.8 3.8 302 11 307 165 -2 0 -1.9 -2.1 02/22/2006 19:40:00 8.7 1.8 13.7 4.6 8.6 1.8 13.7 4.2 7 1.7 11.5 2.3 298 10 297 165 -2 0 -1.9 -2.1 02/22/2006 19:50:00 10.1 1.5 14.1 6.5 10 1.4 13.7 6.5 8.1 1.4 11.8 4.6 298 9 300 165 -2 0 -1.9 -2.1 02/22/2006 20:00:00 11.5 1.5 17.9 8 11.4 1.5 17.9 7.6 9.1 1.5 14.1 6.1 301 7 297 165 -1.8 0 -1.7 -2.1 02/22/2006 20:10:00 9.9 1.1 12.6 7.2 9.8 1.1 12.6 7.2 8.2 1.4 12.6 5.3 300 9 289 165 -1.9 0.1 -1.7 -2.1 02/22/2006 20:20:00 10.8 1.3 14.9 6.8 10.6 1.3 14.1 6.5 8.7 1.4 12.6 5.3 295 8 302 165 -1.9 0 -1.7 -2.1 02/22/2006 20:30:00 12.5 1.5 15.6 8.8 12.4 1.5 15.6 8.4 9.5 1.3 14.9 6.5 301 6 291 165 -1.7 0 -1.4 -1.9 02/22/2006 20:40:00 11.7 1.3 16.1 8.4 11.5 1.3 14.9 8 9.1 1.3 12.6 6.1 301 7 307 165 -1.7 0 -1.4 -1.9 02/22/2006 20:50:00 10.7 1.3 14.9 8.4 10.7 1.3 14.5 8 8.8 1.4 13.3 5.7 301 9 283 165 -1.7 0 -1.4 -1.9 02/22/2006 21:00:00 12 2.2 16.4 7.6 11.9 2.2 16.8 7.6 9.4 1.5 14.1 6.1 302 7 302 165 -1.7 0 -1.4 -1.9 02/22/2006 21:10:00 14.4 1.3 17.9 11.1 14.3 1.3 18.3 11.1 10.7 1.2 14.9 8 300 6 300 165 -1.4 0 -1.2 -1.4 02/22/2006 21:20:00 13.6 1.5 19.5 9.9 13.6 1.5 19.5 9.9 10.4 1.5 16.8 7.6 300 6 306 165 -1.5 0 -1.2 -1.7 02/22/2006 21:30:00 12.3 1.4 15.3 8.4 12.3 1.4 15.6 8.8 9.6 1.5 14.5 6.5 300 6 305 165 -1.5 0 -1.4 -1.7 02/22/2006 21:40:00 12.8 1.4 16.1 9.1 12.7 1.4 15.6 9.1 10.1 1.4 14.1 7.2 303 6 303 165 -1.6 0 -1.4 -1.7 02/22/2006 21:50:00 10.6 1.3 14.5 6.8 10.5 1.3 14.5 6.8 8.8 1.2 11.8 6.1 305 7 305 165 -1.8 0.1 -1.4 -1.9 02/22/2006 22:00:00 9.8 1.1 12.6 7.2 9.7 1.1 12.2 7.2 8.4 1.4 12.2 4.9 305 7 310 165 -1.8 0 -1.7 -1.9 02/22/2006 22:10:00 9.9 1.5 13.7 5.7 9.8 1.5 13 5.7 8.2 1.6 11.8 3.8 306 6 305 165 -1.8 0 -1.7 -1.9 02/22/2006 22:20:00 8.4 1.3 12.6 6.1 8.4 1.3 12.6 6.1 6.9 1.1 9.9 4.6 301 8 295 165 -1.7 0 -1.4 -1.9 02/22/2006 22:30:00 9.4 2 13.3 5.7 9.4 2 13 5.3 7.3 1.4 11.5 4.2 302 9 303 165 -1.3 0.1 -1.2 -1.7 02/22/2006 22:40:00 7.1 1.1 10.3 4.2 7 1 9.9 4.2 5.8 1 9.9 3 299 9 292 165 -1.5 0.1 -1.2 -1.7 02/22/2006 22:50:00 8.4 1.3 11.5 4.2 8.4 1.3 11.5 3.8 6.6 1.2 11.1 3.8 297 9 295 165 -1 0.2 -0.8 -1.4 02/22/2006 23:00:00 5.8 1.5 9.5 1.9 6 1.3 9.5 3 5.5 1.2 9.1 2.3 282 13 302 165 -0.9 0 -0.8 -1.2 02/22/2006 23:10:00 3 1.3 7.2 0.4 3.3 1.3 6.8 0.4 3 1.5 7.2 0.4 241 49 244 165 -1.1 0 -0.8 -1.4 02/22/2006 23:20:00 1.7 1.4 5.3 0.4 1.8 1.6 5.3 0.4 1.8 1.4 4.9 0.4 210 64 275 165 -1.1 0 -0.8 -1.4 02/22/2006 23:30:00 1.8 1 4.6 0.4 1.8 1 4.2 0.4 2.1 0.9 4.2 0.4 168 36 249 165 -1.2 0 -0.8 -1.4 02/22/2006 23:40:00 2.6 1.1 5.7 0.4 2.6 1 5.7 0.4 2.7 0.9 5.7 0.4 182 64 238 165 -1.2 0.1 -0.8 -1.4 02/22/2006 23:50:00 0.9 0.7 3 0.4 1 0.7 3.8 0.4 1.3 0.7 3.4 0.4 182 79 268 165 -0.9 0 -0.5 -1 02/23/2006 00:00:00 0.6 0.5 2.6 0.4 0.6 0.5 2.6 0.4 0.7 0.5 3 0.4 177 82 227 165 -0.9 0 -0.8 -1.2 02/23/2006 00:10:00 1.1 0.8 3.4 0.4 1.1 0.8 3.8 0.4 1.3 0.8 3.4 0.4 42 90 338 165 -1 0 -0.8 -1.2 02/23/2006 00:20:00 1.5 0.9 4.9 0.4 1.5 1 4.6 0.4 1.8 0.8 3.8 0.4 216 56 279 165 -1 0 -0.8 -1.2 02/23/2006 00:30:00 1.5 1.1 4.2 0.4 1.5 1.2 4.2 0.4 1.7 1.1 3.8 0.4 207 43 281 165 -1 0 -0.8 -1.2 02/23/2006 00:40:00 1.9 0.9 4.2 0.4 2.1 0.9 4.2 0.4 2.3 0.8 4.9 0.4 262 20 256 165 -1 0 -0.8 -1.4 02/23/2006 00:50:00 0.8 0.6 2.6 0.4 0.9 0.6 2.6 0.4 1.1 0.6 2.6 0.4 193 29 246 165 -1 0 -0.8 -1.2 02/23/2006 01:00:00 1 0.8 3 0.4 1 0.8 2.6 0.4 1.4 0.8 3 0.4 184 24 150 165 -1.1 0 -0.8 -1.2 02/23/2006 01:10:00 0.8 0.4 1.9 0.4 0.8 0.5 1.9 0.4 1.2 0.6 2.3 0.4 162 18 145 165 -0.9 0 -0.8 -1.2 02/23/2006 01:20:00 0.4 0.1 1.1 0.4 0.4 0.1 1.1 0.4 0.6 0.3 1.5 0.4 130 39 144 165 -0.9 0 -0.8 -1 02/23/2006 01:30:00 0.8 0.7 3 0.4 0.8 0.8 3.4 0.4 1.1 0.6 3.4 0.4 307 56 272 165 -0.9 0 -0.8 -1 02/23/2006 01:40:00 2.5 0.6 4.2 0.7 2.8 0.5 4.2 1.5 2.9 0.5 3.8 1.5 274 10 278 165 -0.9 0 -0.8 -0.8 02/23/2006 01:50:00 2.6 0.6 3.8 1.1 3 0.5 4.2 1.9 2.9 0.5 4.2 1.9 274 7 279 165 -0.9 0 -0.8 -1 02/23/2006 02:00:00 2.7 0.7 4.6 0.7 3.4 0.8 4.9 1.5 3.3 0.8 4.9 1.9 266 12 255 165 -0.9 0 -0.8 -1.2 02/23/2006 02:10:00 2.7 0.5 3.8 1.5 3.6 0.4 4.6 2.6 3.5 0.3 4.6 3 264 6 254 165 -0.9 0 -0.8 -1.2 02/23/2006 02:20:00 2.7 0.7 4.6 1.1 3.8 0.5 4.9 1.9 3.5 0.5 4.6 2.3 265 6 271 165 -1 0 -0.8 -1.2 02/23/2006 02:30:00 2.3 0.6 3.8 0.7 3.3 0.5 4.2 1.9 3.1 0.4 3.8 2.3 264 5 277 165 -0.9 0 -0.8 -1.2 02/23/2006 02:40:00 2.2 0.7 4.2 0.4 3 0.6 4.2 1.5 2.9 0.4 3.8 1.9 259 8 275 165 -0.9 0 -0.8 -1.2 02/23/2006 02:50:00 1.4 0.4 2.3 0.4 1.6 0.4 2.3 0.4 2 0.4 3 1.1 221 11 242 165 -0.9 0 -0.8 -1.2 02/23/2006 03:00:00 0.7 0.3 1.5 0.4 0.7 0.4 1.9 0.4 1.3 0.4 1.9 0.4 225 13 213 165 -0.9 0 -0.8 -1 02/23/2006 03:10:00 0.8 0.3 1.5 0.4 0.7 0.4 1.5 0.4 1.4 0.3 1.9 0.4 209 16 217 165 -0.8 0 -0.5 -0.8 02/23/2006 03:20:00 0.5 0.2 1.1 0.4 0.5 0.3 1.1 0.4 1 0.4 1.9 0.4 210 14 228 165 -0.8 0 -0.8 -0.8 02/23/2006 03:30:00 0.6 0.3 1.5 0.4 0.8 0.4 1.9 0.4 1.3 0.3 2.3 0.4 227 23 260 165 -0.8 0 -0.5 -1 02/23/2006 03:40:00 2.9 1.3 5.3 0.4 3.4 1.3 5.7 0.7 3.3 1.1 5.3 1.5 271 11 271 165 -0.7 0 -0.5 -1 02/23/2006 03:50:00 2.8 1.2 5.3 0.4 3.2 1 5.7 0.4 3.1 1 5.7 1.1 272 19 277 165 -0.9 0 -0.8 -1.2 02/23/2006 04:00:00 1.7 0.9 4.2 0.4 2.1 0.9 4.2 0.4 2 0.9 4.6 0.4 272 15 287 165 -1.2 0 -1 -1.2 02/23/2006 04:10:00 1.2 0.8 4.2 0.4 1.4 0.8 4.2 0.4 1.7 0.5 3.4 0.4 244 22 286 165 -1.2 0 -1 -1.4 02/23/2006 04:20:00 1.6 0.6 2.6 0.4 1.8 0.6 3 0.4 2.1 0.5 3.4 1.1 242 20 257 165 -0.9 0.1 -0.8 -1.2 02/23/2006 04:30:00 1.3 0.8 3.8 0.4 1.6 1 3.8 0.4 1.9 0.9 3.4 0.4 249 8 253 165 -0.8 0 -0.5 -1 02/23/2006 04:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.5 0.2 1.5 0.4 225 4 165 165 -0.8 0 -0.5 -0.8 02/23/2006 04:50:00 0.6 0.4 1.9 0.4 0.5 0.4 1.9 0.4 1.4 0.5 2.3 0.4 166 26 147 165 -1 0.2 -0.8 -1.4 02/23/2006 05:00:00 1.4 0.5 2.3 0.4 1.5 0.5 2.3 0.4 1.9 0.4 2.6 1.1 163 13 151 165 -1.4 0 -1.2 -1.4 02/23/2006 05:10:00 0.9 0.6 2.3 0.4 1 0.6 2.3 0.4 1.5 0.4 2.6 0.7 162 7 162 165 -1.5 0 -1.4 -1.7 02/23/2006 05:20:00 2.6 0.4 3.4 1.9 2.6 0.4 3.4 1.9 2.9 0.3 3.4 1.9 152 8 155 165 -1.4 0 -1.2 -1.4 02/23/2006 05:30:00 1.5 0.4 2.3 0.7 1.7 0.4 2.3 0.7 2.1 0.3 2.6 1.1 164 10 141 165 -1.3 0 -1.2 -1.4 02/23/2006 05:40:00 2 0.7 3.4 0.4 2 0.6 3.4 0.7 2.3 0.6 3.8 1.1 175 9 184 165 -1.3 0 -1.2 -1.4 02/23/2006 05:50:00 3.2 0.3 3.8 2.3 3.2 0.3 3.8 2.3 3.4 0.3 4.2 2.6 179 5 179 165 -1.3 0.1 -1.2 -1.4 02/23/2006 06:00:00 3.5 0.2 4.2 3 3.5 0.2 4.2 3 3.9 0.2 4.6 3.4 181 1 180 165 -1.3 0 -1.2 -1.4 02/23/2006 06:10:00 3.3 0.3 3.8 2.6 3.3 0.3 3.8 2.6 3.6 0.3 4.2 3 179 4 183 165 -1.1 0 -1 -1.4 02/23/2006 06:20:00 2.6 0.5 3.4 1.5 2.7 0.4 3.4 1.5 3 0.5 3.8 1.5 175 3 173 165 -1 0 -0.8 -1.2 02/23/2006 06:30:00 2 0.3 2.6 1.5 2 0.3 2.6 1.5 2.3 0.3 3 1.9 178 4 174 165 -1.3 0 -1.2 -1.4 02/23/2006 06:40:00 1.5 0.3 2.3 0.7 1.4 0.3 2.3 0.7 1.9 0.3 2.6 1.1 173 6 166 165 -1.2 0 -1.2 -1.4 02/23/2006 06:50:00 2.3 0.8 4.6 0.4 2.3 0.7 4.6 0.7 2.5 0.6 4.2 1.1 198 11 205 165 -1 0 -0.8 -1.4 02/23/2006 07:00:00 3 0.8 4.6 1.1 3 0.8 4.6 1.1 3.2 0.6 4.6 1.5 199 13 206 165 -1 0 -0.8 -1.2 02/23/2006 07:10:00 3.5 0.4 4.2 2.6 3.6 0.4 4.6 2.6 3.4 0.4 4.2 2.3 209 4 209 165 -1.1 0 -1 -1.2 02/23/2006 07:20:00 3.1 0.6 4.6 1.9 3.2 0.6 4.9 1.9 3.3 0.6 4.9 1.9 212 6 207 165 -1.3 0 -1.2 -1.4 02/23/2006 07:30:00 2.2 0.5 3.4 1.5 2.3 0.5 3.4 1.5 2.6 0.4 3.4 1.5 215 4 217 165 -1.3 0 -1.2 -1.4 02/23/2006 07:40:00 2.1 0.6 3.4 0.4 2 0.6 3.4 0.4 2.4 0.5 3.4 1.5 187 17 183 165 -1.3 0 -1.2 -1.4 02/23/2006 07:50:00 1.8 0.4 3 0.7 1.6 0.5 3 0.4 2.1 0.4 3 1.1 182 11 191 165 -1.4 0 -1.2 -1.4 02/23/2006 08:00:00 1.6 0.5 3 0.4 1.6 0.5 3 0.4 1.7 0.4 2.6 0.7 197 11 203 165 -1.4 0 -1.2 -1.4 02/23/2006 08:10:00 1.8 0.6 3 0.4 1.8 0.6 3.4 0.4 1.8 0.4 3 1.1 229 18 242 165 -1.3 0 -1.2 -1.4 02/23/2006 08:20:00 0.8 0.6 2.6 0.4 0.9 0.6 3 0.4 1 0.5 2.3 0.4 224 27 274 165 -1.3 0 -1.2 -1.4 02/23/2006 08:30:00 2.4 1.6 5.3 0.4 2.7 1.7 5.3 0.4 2.5 1.7 5.3 0.4 251 27 287 165 -1 0.4 -0.1 -1.4 02/23/2006 08:40:00 2.5 1.2 6.8 0.4 3.2 1.5 6.8 0.4 2.9 1.4 6.8 0.7 281 22 261 165 -0.3 0 -0.1 -0.5 02/23/2006 08:50:00 2.7 0.6 4.6 1.1 2.9 0.5 4.6 1.5 2.6 0.5 4.6 1.5 306 8 300 165 -0.6 0 -0.5 -0.8 02/23/2006 09:00:00 3.2 1 5.3 0.4 3.6 1 5.7 0.4 3.4 1 5.3 0.4 283 19 268 165 -0.3 0.1 -0.1 -0.5 02/23/2006 09:10:00 5.2 1.2 8 3 5.3 1.2 8.4 3 4.7 1.3 7.6 2.3 292 9 291 165 -0.3 0 -0.1 -0.3 02/23/2006 09:20:00 4.5 1.2 7.2 1.5 4.8 1.1 7.6 2.6 4.8 1.1 8.4 2.6 281 10 277 165 -0.3 0 -0.1 -0.5 02/23/2006 09:30:00 5.7 1.8 11.1 2.6 5.7 1.7 11.1 2.6 5.5 1.7 9.9 2.6 310 16 309 165 -0.6 0 -0.5 -0.8 02/23/2006 09:40:00 9.3 0.8 12.2 6.8 9.2 0.8 11.8 6.8 8.4 1 10.7 4.6 311 6 307 165 -0.8 0 -0.5 -0.8 02/23/2006 09:50:00 8.7 1 11.1 6.1 8.6 1 11.1 6.1 8.1 1.3 10.7 5.3 312 7 310 165 -0.8 0 -0.8 -1 02/23/2006 10:00:00 10.4 1 13 8.4 10.3 1 13 8 9.2 1.8 13 5.3 309 11 312 165 -0.8 0 -0.5 -0.8 02/23/2006 10:10:00 11.7 1.1 14.9 9.5 11.8 1.1 14.9 9.5 9.1 1.2 12.6 6.1 294 4 298 165 -0.9 0 -0.8 -0.8 02/23/2006 10:20:00 11.2 1 13.3 8.4 11.2 1.1 13.3 8.4 8.7 1.3 12.2 5.7 294 5 296 165 -0.9 0 -0.8 -0.8 02/23/2006 10:30:00 9.6 1.3 13 6.1 9.5 1.3 12.6 6.1 7.8 1.3 11.5 4.6 304 9 295 165 -0.8 0 -0.5 -0.8 02/23/2006 10:40:00 8.1 1.3 11.8 4.6 8.1 1.3 12.2 4.9 6.9 1.5 11.5 4.2 306 9 310 165 -0.9 0 -0.8 -1.2 02/23/2006 10:50:00 6.8 1.4 9.9 3.4 6.8 1.4 9.9 3.4 5.7 1.3 9.5 2.6 304 10 297 165 -1 0 -0.8 -1.2 02/23/2006 11:00:00 4.6 1.2 7.2 1.5 4.7 1.2 7.2 1.9 4.2 1.2 7.6 1.9 299 15 310 165 -1 0 -0.8 -1.2 02/23/2006 11:10:00 5 1.6 9.1 2.3 5 1.5 9.1 2.3 4.4 1.3 9.1 1.9 310 14 312 165 -1 0 -0.8 -1.2 02/23/2006 11:20:00 6.3 1.4 11.1 2.3 6.2 1.4 11.1 2.3 6.1 1.4 9.9 2.6 323 17 315 165 -1 0 -0.8 -1.2 02/23/2006 11:30:00 7.8 1.5 10.7 4.9 7.8 1.6 10.7 4.6 7.4 1.6 11.1 4.2 322 14 313 165 -0.9 0 -0.5 -1.2 02/23/2006 11:40:00 9.6 1.6 13 6.1 9.6 1.5 13 5.7 9.2 2 13 4.9 316 9 319 165 -1.2 0 -0.8 -1.4 02/23/2006 11:50:00 11.2 1 14.1 8.4 11.1 1 14.1 8.4 10.8 1.1 13.3 8 319 6 307 165 -1.3 0 -1.2 -1.4 02/23/2006 12:00:00 8.8 1.3 12.2 6.1 8.7 1.3 12.2 6.1 8.2 1.5 11.8 4.9 323 11 311 165 -1.3 0 -1.2 -1.4 02/23/2006 12:10:00 7 1.1 9.9 4.6 6.9 1.1 9.9 4.6 6.6 1.1 9.5 3.8 323 8 315 165 -1.2 0 -1 -1.2 02/23/2006 12:20:00 5.6 1 8 2.6 5.6 1 8 3 5 1.2 7.6 1.9 313 11 302 165 -1.2 0.1 -0.8 -1.4 02/23/2006 12:30:00 5.6 0.9 8 3.4 5.4 0.9 8 3 5.3 0.8 8 3.4 337 14 344 165 -1.5 0 -1.4 -1.7 02/23/2006 12:40:00 7.1 1.3 9.9 4.2 7 1.3 9.9 4.2 6.6 1.4 11.1 3.8 320 8 323 165 -1.6 0.1 -1.2 -1.7 02/23/2006 12:50:00 7.3 1.1 10.3 4.6 7.2 1.1 10.7 4.2 6.9 1 9.9 4.2 320 10 305 165 -1.3 0 -1.2 -1.4 02/23/2006 13:00:00 7 1 9.5 4.9 7 1 9.5 4.9 6.6 1.1 9.5 3.8 318 9 310 165 -1.4 0 -1.2 -1.4 02/23/2006 13:10:00 6.7 1.3 9.1 4.6 6.6 1.3 9.1 3.4 6.3 1.2 9.1 3.8 322 15 313 165 -1.3 0.1 -1 -1.4 02/23/2006 13:20:00 5 0.9 7.6 2.6 4.8 1.1 7.6 1.9 4.7 0.8 7.2 2.6 331 22 313 165 -1.4 0 -1.2 -1.4 02/23/2006 13:30:00 5.2 0.9 6.8 2.6 3.7 0.9 6.5 1.9 5.2 0.9 6.8 2.6 359 6 358 165 -1.6 0 -1.4 -1.9 02/23/2006 13:40:00 5.3 0.7 6.8 3.4 4 0.9 6.1 2.3 5.3 0.9 7.6 2.6 359 10 354 165 -2 0.1 -1.7 -2.1 02/23/2006 13:50:00 5.6 0.8 7.6 3 4.6 1.2 8 2.3 5.7 0.8 8 3 352 10 338 165 -1.9 0 -1.7 -2.1 02/23/2006 14:00:00 3.3 1.1 5.7 0.4 3.3 1 5.7 0.7 2.9 1 4.9 0.4 329 17 350 165 -1.4 0.1 -1.2 -1.7 02/23/2006 14:10:00 5.2 1.4 8.4 2.3 5.2 1.4 8.8 1.9 4.7 1.2 8.4 1.1 319 12 307 165 -1.2 0 -1 -1.4 02/23/2006 14:20:00 7.2 1 9.9 4.6 7.2 1 9.5 4.2 6.5 1.1 9.1 3.8 323 16 310 165 -1.4 0 -1.2 -1.4 02/23/2006 14:30:00 7.2 1 9.5 4.6 7 1.1 9.5 3.4 6.7 1 10.3 4.2 339 12 353 165 -1.5 0 -1.4 -1.7 02/23/2006 14:40:00 10.2 1.2 13.3 7.2 10.1 1.4 13.7 6.1 9.9 1.3 14.5 5.7 339 9 327 165 -1.8 0.2 -1.4 -2.1 02/23/2006 14:50:00 8.8 1.3 13 6.5 8.7 1.3 13 6.1 8.5 1.3 12.6 5.7 324 8 338 165 -2.5 0.1 -2.1 -2.8 02/23/2006 15:00:00 7.7 1 9.9 4.2 7.5 1 9.9 4.2 7.2 1 9.5 4.6 324 14 324 165 -2.2 0.1 -1.9 -2.6 02/23/2006 15:10:00 9.2 1.1 12.6 6.1 8.9 1.1 12.2 5.7 8.8 1.1 12.2 6.1 333 12 351 165 -2 0 -1.9 -2.1 02/23/2006 15:20:00 9.2 1 12.2 6.5 9.1 1.1 12.2 6.5 8.6 1.2 13 4.9 316 11 307 165 -2.2 0 -1.9 -2.4 02/23/2006 15:30:00 9.2 1.5 13 5.7 9.2 1.5 12.6 5.7 7.8 1.1 11.1 4.9 312 10 313 165 -2 0 -1.7 -2.1 02/23/2006 15:40:00 10.8 0.9 13.3 8.4 10.7 0.9 13 8.4 9.7 1.3 13.3 6.8 315 8 334 165 -2.1 0 -1.9 -2.4 02/23/2006 15:50:00 10 1.2 13.7 6.8 9.9 1.2 13.3 6.8 9.3 1.3 13 5.3 326 13 332 165 -1.8 0 -1.4 -2.1 02/23/2006 16:00:00 11.1 1.2 14.1 8.8 10.9 1.3 14.9 7.6 10.9 1.3 14.5 8 338 9 338 165 -1.4 0.1 -1.2 -1.7 02/23/2006 16:10:00 9.5 1.7 14.1 5.3 9.2 1.7 13.3 3.8 9.3 1.7 13.7 5.7 341 11 1 165 -1.2 0 -1 -1.4 02/23/2006 16:20:00 9.5 1.2 11.8 6.5 9.3 1.4 12.2 4.9 9.2 1.3 12.2 4.9 337 11 341 165 -1.2 0 -1 -1.2 02/23/2006 16:30:00 9.3 1.2 13.3 6.1 9.1 1.2 13 5.7 8.5 1.4 12.2 4.9 317 12 300 165 -1.3 0 -1 -1.4 02/23/2006 16:40:00 10.1 1.4 14.9 6.8 9.8 1.2 14.9 6.8 9.5 1.3 14.9 6.5 326 13 358 165 -1.2 0.2 -0.8 -1.4 02/23/2006 16:50:00 10.1 1.7 14.1 6.1 9.8 1.8 13.7 5.7 9.8 1.7 13.7 5.7 342 10 351 165 -1.4 0.2 -0.8 -1.7 02/23/2006 17:00:00 8.3 1.5 11.5 4.2 8.1 1.5 11.5 3.8 8 1.5 11.5 3.4 336 13 348 165 -0.9 0.1 -0.5 -1.2 02/23/2006 17:10:00 8.1 1.3 11.1 4.9 7.9 1.4 11.1 4.6 7.7 1.3 10.7 4.2 332 13 338 165 -1.3 0.2 -0.8 -1.7 02/23/2006 17:20:00 9.4 1.2 13 5.7 9 1.5 12.2 4.6 9.2 1.2 12.2 6.1 342 10 355 165 -1.7 0 -1.4 -1.9 02/23/2006 17:30:00 8.8 1.4 13.3 4.9 8.5 1.6 13.3 3.8 8.6 1.5 13 4.9 335 18 325 165 -1.9 0.1 -1.7 -2.1 02/23/2006 17:40:00 10.1 1.5 14.9 6.1 9.6 2 14.5 4.9 9.9 1.7 14.5 6.1 340 16 324 165 -2.4 0.2 -1.9 -2.8 02/23/2006 17:50:00 11.1 1.3 14.5 8.4 11 1.7 14.9 5.7 11 1.4 14.9 7.2 341 9 345 165 -2.8 0 -2.6 -2.8 02/23/2006 18:00:00 10.1 1.1 13.7 7.6 9.6 1.5 13.7 5.7 9.8 1.3 13.3 6.5 339 12 340 165 -2.7 0 -2.6 -2.8 02/23/2006 18:10:00 9.8 1.1 13 6.5 9.8 1.2 13.3 6.8 9.4 1.3 13.3 6.8 327 14 346 165 -2.5 0 -2.1 -2.8 02/23/2006 18:20:00 10.2 1.6 15.6 6.8 10 1.5 15.3 6.8 9.8 1.7 15.6 6.1 330 15 352 165 -2.2 0 -2.1 -2.6 02/23/2006 18:30:00 11.3 1.5 16.8 7.6 11 1.7 16.8 4.9 10.8 1.4 14.1 7.2 325 17 317 165 -2.1 0 -1.9 -2.1 02/23/2006 18:40:00 11.3 1.2 14.1 8 11.2 1.2 13.7 7.6 10.9 1.5 14.5 7.6 319 8 320 165 -2.3 0 -1.9 -2.6 02/23/2006 18:50:00 13.1 1.7 17.9 8.4 13.1 1.8 17.9 8.4 12.8 1.8 18.3 7.6 322 10 339 165 -2.5 0 -2.1 -2.6 02/23/2006 19:00:00 13.8 1.5 17.9 10.7 13.6 1.5 17.6 10.3 13.4 1.5 17.9 9.1 322 7 337 165 -2.4 0 -2.1 -2.6 02/23/2006 19:10:00 13.6 1.5 17.6 10.3 13.4 1.5 17.6 9.9 13 1.5 17.2 9.1 319 7 309 165 -2.5 0 -2.4 -2.6 02/23/2006 19:20:00 15.1 1.7 20.2 10.7 15 1.7 20.2 11.1 14.8 1.8 19.5 10.3 320 6 327 165 -2.5 0 -2.4 -2.8 02/23/2006 19:30:00 15.3 1.5 19.5 11.5 15.2 1.5 19.9 11.5 14.8 1.5 18.3 11.5 318 6 316 165 -2.5 0 -2.4 -2.6 02/23/2006 19:40:00 14.5 1.8 17.6 9.5 14.3 1.8 17.6 9.5 14 2 18.3 9.1 321 9 326 165 -2.5 0 -2.4 -2.6 02/23/2006 19:50:00 15.3 1.6 19.5 11.1 15.1 1.6 19.5 10.7 14.3 1.9 17.9 9.9 319 10 332 165 -2.5 0 -2.4 -2.6 02/23/2006 20:00:00 13.5 1.9 19.9 8.4 13.3 2.1 19.5 8 12.7 1.8 16.8 7.2 323 15 307 165 -2.6 0 -2.6 -2.8 02/23/2006 20:10:00 13 1.7 17.6 8.8 12.9 1.7 17.2 8.8 12.2 1.9 17.6 7.2 317 9 314 165 -2.7 0 -2.6 -2.8 02/23/2006 20:20:00 13.2 1.9 17.9 8.8 12.9 2 17.9 8.8 12.8 1.9 19.5 8.4 327 15 327 165 -2.8 0 -2.6 -3 02/23/2006 20:30:00 12.3 1.8 18.3 8.4 12 1.9 18.3 6.8 11.9 1.7 17.6 8.4 334 11 328 165 -2.9 0 -2.6 -3 02/23/2006 20:40:00 11.9 1.7 15.6 8 11.8 1.7 15.6 7.2 11 1.7 16.4 6.5 326 15 331 165 -2.8 0 -2.6 -2.8 02/23/2006 20:50:00 12.8 1.7 19.1 7.6 12.8 1.7 18.7 7.2 11.9 2 18.7 5.3 319 13 325 165 -2.6 0.1 -2.6 -2.8 02/23/2006 21:00:00 13.8 2.1 19.5 8.4 13.7 2.1 19.1 8.4 12.6 2.3 18.3 6.8 317 13 302 165 -2.6 0.1 -2.4 -2.8 02/23/2006 21:10:00 13 1.8 19.5 8.4 12.9 1.8 19.1 8.4 12 1.9 16.8 7.2 314 10 311 165 -2.5 0 -2.4 -2.6 02/23/2006 21:20:00 11.9 1.7 16.4 7.6 11.9 1.7 16.4 6.8 10.9 1.7 15.3 6.1 316 13 313 165 -2.5 0 -2.4 -2.8 02/23/2006 21:30:00 12.2 2.2 18.3 7.2 12.2 2.3 17.9 6.5 11.3 2.3 17.6 6.1 316 12 342 165 -2.6 0 -2.6 -2.8 02/23/2006 21:40:00 11.3 1.6 15.6 6.8 11.2 1.6 16.1 6.8 10.3 1.7 16.1 6.8 313 8 310 165 -2.7 0 -2.6 -2.8 02/23/2006 21:50:00 10.6 1.8 17.6 6.1 10.5 1.8 17.6 5.7 9.9 2.1 16.8 5.7 319 13 312 165 -2.7 0 -2.6 -2.8 02/23/2006 22:00:00 11.1 1.7 15.3 7.2 11 1.7 15.3 7.2 9.8 1.7 14.9 5.3 311 10 321 165 -2.7 0 -2.6 -2.8 02/23/2006 22:10:00 10.7 1.7 16.1 6.5 10.6 1.7 16.1 6.1 10.2 1.6 14.1 6.5 321 12 310 165 -2.7 0 -2.6 -2.8 02/23/2006 22:20:00 10 1.6 14.9 6.8 10 1.6 14.5 6.5 9.4 1.7 14.5 4.9 318 14 322 165 -2.8 0 -2.6 -3 02/23/2006 22:30:00 10.4 1.5 15.6 5.7 10.3 1.5 16.1 6.1 9.7 1.7 16.4 5.7 321 12 320 165 -3 0.1 -2.8 -3.3 02/23/2006 22:40:00 10.8 1.8 16.1 6.1 10.5 2.1 16.4 4.2 10.5 2 17.2 6.8 337 12 339 165 -3.3 0 -3 -3.5 02/23/2006 22:50:00 10.9 1.4 15.6 7.6 10.3 1.5 15.6 6.1 10.2 1.3 14.9 6.8 329 21 344 165 -3.4 0 -3.3 -3.5 02/23/2006 23:00:00 11.2 1.7 15.6 6.8 10.6 1.5 15.3 4.6 10.9 1.6 15.6 7.6 337 14 4 165 -3.5 0 -3.3 -3.5 02/23/2006 23:10:00 11.1 1.2 14.5 6.8 11 1.3 14.1 6.5 10.9 1.4 14.9 6.8 328 13 321 165 -3.5 0 -3.5 -3.5 02/23/2006 23:20:00 11 1.4 15.6 6.5 10.9 1.4 14.9 6.5 10.6 1.4 14.5 6.5 322 12 305 165 -3.5 0 -3.3 -3.5 02/23/2006 23:30:00 11.5 1.8 16.1 7.2 11.3 1.8 15.3 6.8 10.8 2 16.1 6.8 327 17 340 165 -3.5 0 -3.3 -3.5 02/23/2006 23:40:00 11.8 1.5 16.4 7.6 11.1 1.6 15.6 6.8 11.4 1.5 15.3 7.6 340 13 11 165 -3.6 0 -3.5 -3.7 02/23/2006 23:50:00 11.4 1.5 15.6 8 11 1.8 15.6 6.5 11.2 1.5 15.3 8 341 11 338 165 -3.6 0 -3.3 -3.5 02/24/2006 00:00:00 11.5 1.9 16.4 7.2 10.9 2 16.8 6.5 10.9 1.8 15.6 6.1 332 17 345 165 -3.6 0 -3.5 -3.5 02/24/2006 00:10:00 11.1 1.6 15.3 6.8 10.9 1.7 16.1 6.1 10.8 1.8 14.9 6.1 327 13 349 165 -3.5 0.1 -3.3 -3.5 02/24/2006 00:20:00 13 2.7 19.5 6.8 13 2.9 19.5 6.8 12.8 2.9 19.5 6.8 337 10 343 165 -3.5 0 -3.3 -3.7 02/24/2006 00:30:00 12.6 1.4 16.4 8 12.4 1.5 16.1 8 12 1.5 15.6 7.6 325 15 315 165 -3.5 0 -3.3 -3.5 02/24/2006 00:40:00 12.1 1.7 17.2 7.6 11.7 1.9 17.6 6.8 11.5 1.9 17.6 6.1 335 15 345 165 -3.6 0 -3.5 -3.5 02/24/2006 00:50:00 11.4 1.7 16.1 7.2 11 1.7 14.9 6.5 11.3 1.7 16.1 6.8 335 13 4 165 -3.5 0 -3.3 -3.5 02/24/2006 01:00:00 14.3 2.6 20.6 6.5 13.8 2.7 20.2 5.7 14.2 2.6 21.4 6.8 342 11 343 165 -3.5 0 -3.3 -3.5 02/24/2006 01:10:00 10.6 1.3 14.5 6.1 10.6 1.4 14.5 6.1 10.2 1.7 15.3 6.5 327 15 344 165 -3.5 0.1 -3.3 -3.7 02/24/2006 01:20:00 12.1 1.3 16.8 8.4 12.1 1.3 16.8 8.4 11.5 1.5 15.6 8 320 11 322 165 -3.4 0 -3.3 -3.7 02/24/2006 01:30:00 12.4 2 17.2 7.6 12.3 2 17.6 6.8 11.7 2.2 17.2 6.5 318 11 309 165 -3.3 0 -3.3 -3.5 02/24/2006 01:40:00 11.7 1.7 16.4 7.6 11.6 1.7 16.4 7.2 10.9 1.7 14.9 6.5 316 12 318 165 -3.4 0 -3.3 -3.5 02/24/2006 01:50:00 12 2.1 18.7 5.7 11.8 2.1 19.5 6.1 11.2 1.7 16.8 6.5 325 17 302 165 -3.4 0 -3.3 -3.5 02/24/2006 02:00:00 14 1.7 19.1 9.9 13.9 1.7 18.7 9.9 13 1.9 18.3 6.8 317 11 302 165 -3.4 0 -3.3 -3.5 02/24/2006 02:10:00 13.5 2.2 21.8 7.6 13.5 2.1 21.8 7.6 12 2.3 18.3 5.3 313 12 297 165 -3.4 0 -3.3 -3.5 02/24/2006 02:20:00 13.2 1.6 18.7 8.4 12.9 1.7 19.5 6.8 12.8 1.7 18.3 8.4 332 15 349 165 -3.4 0 -3.3 -3.5 02/24/2006 02:30:00 12.6 1.7 18.3 8.8 12.5 1.7 18.7 8.4 12.1 1.7 19.1 8.8 323 14 351 165 -3.5 0 -3.3 -3.5 02/24/2006 02:40:00 13.2 1.6 18.7 8.8 13 1.6 19.5 8.8 11.9 1.8 16.4 6.5 314 10 309 165 -3.4 0 -3.3 -3.5 02/24/2006 02:50:00 11.7 1.6 17.2 8 11.6 1.6 16.8 8 10.6 1.5 14.5 6.8 316 11 313 165 -3.4 0 -3.3 -3.5 02/24/2006 03:00:00 12.1 1.9 19.5 7.6 12.1 1.8 19.5 7.6 10.9 1.6 16.4 5.3 314 12 304 165 -3.5 0 -3.3 -3.5 02/24/2006 03:10:00 11.5 2.3 17.6 6.5 11.2 2.4 18.7 6.1 11.1 2.5 17.9 6.5 335 13 340 165 -3.6 0 -3.5 -3.7 02/24/2006 03:20:00 12.3 2.1 17.2 7.6 11.9 2.3 17.2 7.2 11.8 2.2 17.2 6.8 338 14 353 165 -3.6 0 -3.5 -3.9 02/24/2006 03:30:00 13.8 2 19.1 8.8 13.7 2.1 19.1 8.4 13.5 2.2 18.7 7.2 333 12 322 165 -3.5 0 -3.3 -3.5 02/24/2006 03:40:00 10.4 3.1 17.6 4.6 9.9 3.3 17.9 3.8 10.2 3.2 16.8 3.4 338 19 330 165 -3.4 0 -3.3 -3.5 02/24/2006 03:50:00 10 2.3 15.6 4.9 9.8 2.2 15.6 4.6 9.6 2.3 16.1 4.9 331 16 326 165 -3.5 0 -3.3 -3.5 02/24/2006 04:00:00 10.1 2.2 16.4 6.1 9.5 2 14.9 4.2 9.7 2.1 15.6 5.3 341 13 359 165 -3.6 0 -3.5 -3.9 02/24/2006 04:10:00 9.2 1.9 13.7 3.4 8.9 1.9 13.3 4.2 8.4 1.7 13.3 3.4 327 21 322 165 -3.7 0 -3.5 -3.9 02/24/2006 04:20:00 8.7 1.6 13.7 4.6 8.6 1.6 13.3 4.6 7.9 1.5 11.8 4.2 316 13 302 165 -3.5 0 -3.3 -3.5 02/24/2006 04:30:00 9.3 1.3 14.9 5.3 9.2 1.3 14.9 5.3 8 1.4 13.3 4.2 309 10 288 165 -3.5 0 -3.3 -3.5 02/24/2006 04:40:00 10.6 1.7 17.9 5.7 10.5 1.7 17.9 5.7 9.8 1.9 16.4 6.1 314 9 314 165 -3.5 0 -3.3 -3.9 02/24/2006 04:50:00 11 1.5 16.4 7.6 10.9 1.5 15.6 6.8 10.1 1.7 16.4 6.8 315 11 318 165 -3.5 0 -3.3 -3.5 02/24/2006 05:00:00 9.9 1.4 14.1 7.2 9.9 1.4 13.7 6.5 9.2 1.3 12.6 4.9 317 15 311 165 -3.6 0 -3.5 -3.5 02/24/2006 05:10:00 10.5 2 15.6 5.7 10.1 2.2 16.4 4.2 10.1 2.2 15.6 4.6 334 18 341 165 -3.6 0 -3.5 -3.7 02/24/2006 05:20:00 9.5 1.5 14.9 6.1 8.8 1.5 15.3 4.6 9.3 1.6 14.5 6.5 338 15 344 165 -3.7 0 -3.5 -3.9 02/24/2006 05:30:00 8.7 1.3 12.6 5.3 8.6 1.3 12.2 5.3 8.2 1.3 12.2 3.8 332 12 325 165 -3.8 0 -3.5 -3.9 02/24/2006 05:40:00 10.3 2.2 15.3 6.1 10 2.3 14.5 4.6 9.9 2.4 15.3 5.3 331 13 321 165 -3.8 0 -3.7 -3.9 02/24/2006 05:50:00 12.7 1.7 17.2 8.4 12.3 1.7 17.2 8 12.5 1.9 17.9 8 340 10 354 165 -3.9 0 -3.7 -3.9 02/24/2006 06:00:00 12.4 1.7 17.2 8.4 12.3 1.7 17.2 6.8 12.1 1.8 17.2 8.4 329 9 316 165 -3.8 0 -3.7 -4.2 02/24/2006 06:10:00 12.3 2.3 22.6 6.8 12.1 2.4 21.8 5.3 11.8 2.4 20.6 6.1 331 11 334 165 -3.9 0 -3.7 -4.2 02/24/2006 06:20:00 13 1.7 17.9 8.8 12.7 1.8 17.6 6.8 12.6 1.7 17.9 8 330 10 331 165 -4 0.1 -3.7 -4.2 02/24/2006 06:30:00 12 1.5 16.1 7.2 11.8 1.5 16.1 6.8 11.5 1.5 15.6 6.8 332 12 326 165 -4.2 0 -3.9 -4.4 02/24/2006 06:40:00 12.9 1.4 16.4 9.1 12.4 1.5 16.4 8.4 12.6 1.3 16.8 8.4 339 10 351 165 -4.3 0 -3.9 -4.6 02/24/2006 06:50:00 12.4 1.8 17.9 8 12.2 1.9 17.6 7.6 11.5 2.1 16.8 5.3 333 13 339 165 -4.2 0 -3.9 -4.4 02/24/2006 07:00:00 13 1.5 17.2 9.5 12.8 1.7 17.2 8.8 12.4 1.7 16.4 8.4 333 11 337 165 -4 0.1 -3.7 -4.2 02/24/2006 07:10:00 11.1 1.7 15.6 6.8 10.9 1.7 16.8 6.1 10.3 1.9 17.2 4.9 335 11 343 165 -4.1 0.1 -3.9 -4.4 02/24/2006 07:20:00 13.9 1.5 18.7 10.3 13.5 1.7 17.9 8.4 13.4 1.6 17.9 9.5 342 9 354 165 -4.1 0 -3.9 -4.4 02/24/2006 07:30:00 13.4 1.8 19.1 8.8 12.5 2.5 19.5 6.5 12.7 2.1 18.7 8 345 13 339 165 -4.2 0 -3.9 -4.4 02/24/2006 07:40:00 13.6 1.7 17.9 8.8 13.1 1.8 17.6 8.8 13.3 1.9 18.3 8.8 343 9 350 165 -4.2 0 -3.9 -4.4 02/24/2006 07:50:00 13 1.7 17.2 8.8 12.3 1.7 17.2 7.6 12.4 1.7 16.4 8.4 344 10 342 165 -4.2 0 -4.2 -4.4 02/24/2006 08:00:00 12.6 1.7 17.9 8.8 12.1 2.4 17.2 6.5 12.2 2 17.2 7.2 344 9 351 165 -4.2 0 -3.9 -4.4 02/24/2006 08:10:00 11 1.6 16.8 7.6 10.7 1.5 15.3 6.5 10.5 1.7 16.4 6.8 339 12 7 165 -4.3 0 -4.2 -4.4 02/24/2006 08:20:00 10.3 1.5 15.3 6.8 9.9 1.7 14.9 6.5 9.8 1.6 13.7 5.7 342 10 332 165 -4.3 0 -4.2 -4.4 02/24/2006 08:30:00 7.6 1.4 11.8 4.2 7.2 1.3 11.8 3.8 6.7 1.5 10.3 3 327 19 358 165 -4.3 0 -4.2 -4.4 02/24/2006 08:40:00 7.7 1.9 15.3 3.8 7.4 1.7 13.7 3.4 6.9 1.7 13.7 3.4 336 16 353 165 -4 0.1 -3.5 -4.4 02/24/2006 08:50:00 9.6 2.1 16.4 5.3 9.2 2.1 16.8 5.3 9 2.1 16.8 4.2 342 12 340 165 -3.4 0 -3.3 -3.9 02/24/2006 09:00:00 7.9 1.6 11.8 4.6 7.4 1.7 12.2 3.8 6.7 1.6 11.5 3.4 339 20 0 165 -3.2 0 -3 -3.5 02/24/2006 09:10:00 8.1 2.3 14.9 3.8 7.6 2.4 15.3 3.4 7.6 2.4 14.5 3.4 338 15 343 165 -3 0 -2.8 -3.3 02/24/2006 09:20:00 6.1 1.6 10.3 2.6 5.6 1.7 10.3 1.9 5.4 1.5 9.9 2.3 338 17 349 165 -2.7 0 -2.6 -2.8 02/24/2006 09:30:00 7 1.5 10.7 3.4 6.6 1.5 10.7 3 6.7 1.6 11.5 3 340 12 2 165 -2.7 0 -2.6 -2.8 02/24/2006 09:40:00 7.3 1.5 10.7 4.2 7 1.6 11.1 3.8 6.6 1.3 9.9 3.8 336 13 334 165 -2.5 0 -2.1 -2.8 02/24/2006 09:50:00 8.8 1.2 11.8 5.7 8 1.5 11.5 4.2 8.2 1.2 11.8 4.9 345 11 354 165 -2.5 0 -2.1 -2.8 02/24/2006 10:00:00 5.6 1.6 10.7 2.3 5 1.7 10.3 1.9 5.3 1.5 9.9 1.9 346 15 339 165 -2.2 0.2 -1.9 -2.8 02/24/2006 10:10:00 7.4 1.3 10.7 3.4 7.1 1.5 11.1 3.4 6.8 1.4 11.8 3.4 337 13 317 165 -2.1 0 -1.9 -2.4 02/24/2006 10:20:00 7.9 1.7 12.2 4.9 7.6 1.8 11.8 3.8 7.6 1.7 11.5 4.6 338 12 328 165 -2.4 0.1 -1.9 -2.6 02/24/2006 10:30:00 8.3 1.3 12.2 4.9 7.5 1.7 11.8 4.2 7.7 1.5 12.2 3.8 342 15 332 165 -2.2 0.1 -2.1 -2.6 02/24/2006 10:40:00 6.5 1.3 10.3 3 6.3 1.3 10.3 2.3 6.1 1.3 8.8 3 336 13 324 165 -2.1 0.2 -1.7 -2.6 02/24/2006 10:50:00 7.1 1.3 9.9 4.2 6.7 1.6 9.5 2.6 6.6 1.2 9.1 3.8 340 18 307 165 -1.8 0 -1.4 -2.1 02/24/2006 11:00:00 8.1 1.5 11.8 5.3 8 1.6 11.8 3.4 7.9 1.5 11.8 5.3 337 9 338 165 -2.1 0.2 -1.9 -2.6 02/24/2006 11:10:00 10.6 1.6 13.7 7.2 10.6 1.7 13.7 5.7 10.4 1.6 14.1 6.8 339 8 321 165 -2.4 0.1 -2.1 -2.6 02/24/2006 11:20:00 10.7 1.3 13.3 7.2 10.6 1.4 13.7 6.8 10.5 1.5 13.7 6.5 338 8 329 165 -2.4 0 -2.1 -2.6 02/24/2006 11:30:00 9.4 1.3 13.7 6.5 9.3 1.3 14.1 6.5 9.1 1.3 13.3 5.3 333 9 334 165 -2.4 0.1 -2.1 -2.6 02/24/2006 11:40:00 9.4 1.2 14.1 6.1 9.3 1.2 14.1 6.5 9.2 1.3 13.7 6.1 335 9 317 165 -2.3 0 -2.1 -2.6 02/24/2006 11:50:00 7.6 1.1 10.3 4.6 7.5 1.2 10.7 4.2 6.8 1.4 10.3 3 329 17 347 165 -1.8 0.1 -1.4 -2.1 02/24/2006 12:00:00 8.9 1.5 13 4.9 8.8 1.5 13.3 5.3 8.2 1.7 13.3 4.2 322 11 316 165 -1.6 0.2 -1.2 -2.1 02/24/2006 12:10:00 9 1.5 12.6 5.7 8.9 1.5 12.6 5.7 8.6 1.5 12.6 5.7 327 11 313 165 -1.9 0.2 -1.2 -2.1 02/24/2006 12:20:00 8.5 1.3 11.8 4.9 8.4 1.3 11.8 4.9 7.6 1.2 10.7 4.2 314 8 300 165 -1.6 0.2 -1.2 -1.9 02/24/2006 12:30:00 8.6 1.5 12.2 4.9 8.5 1.5 12.2 5.3 7.8 1.5 12.2 4.6 315 10 315 165 -1.6 0.1 -1.2 -1.9 02/24/2006 12:40:00 9.3 1 12.6 6.1 9.3 1 12.2 6.5 8.6 1.2 12.2 5.7 313 9 300 165 -1.9 0.1 -1.7 -2.1 02/24/2006 12:50:00 10 1.3 13 6.8 9.8 1.3 13 6.8 9.5 1.3 13.3 5.7 317 6 313 165 -2 0 -1.9 -2.1 02/24/2006 13:00:00 8.7 1 11.8 6.5 8.5 1 11.5 6.5 8 1 11.1 5.7 316 8 311 165 -1.8 0 -1.4 -1.9 02/24/2006 13:10:00 9.1 1.2 12.6 6.8 9 1.2 12.2 6.5 8 1.3 12.2 5.3 311 9 303 165 -1.8 0.2 -1.4 -2.1 02/24/2006 13:20:00 8.5 1 11.8 6.5 8.4 1 11.5 6.1 7.8 1.2 10.7 4.9 313 8 301 165 -1.6 0 -1.2 -1.9 02/24/2006 13:30:00 9.3 1.1 12.2 6.8 9.2 1.2 12.6 6.5 8 1.2 11.5 4.6 303 11 303 165 -1.7 0.1 -1.4 -2.1 02/24/2006 13:40:00 9.5 1.1 12.6 6.5 9.4 1.1 12.6 6.1 8 1.1 11.1 5.3 307 8 289 165 -1.8 0 -1.7 -2.1 02/24/2006 13:50:00 9.2 1.2 13 6.1 9.1 1.1 13 6.5 7.4 1.3 12.2 4.9 303 7 279 165 -1.8 0 -1.7 -1.9 02/24/2006 14:00:00 8.4 1 11.1 4.9 8.3 1 11.1 4.9 7.5 1.2 10.7 5.3 312 9 300 165 -1.5 0 -1.2 -1.7 02/24/2006 14:10:00 8.2 0.9 10.3 5.3 8 0.9 10.7 5.7 7.2 0.9 9.5 4.9 312 11 292 165 -1.4 0.1 -1.2 -1.7 02/24/2006 14:20:00 6.9 1.2 12.6 4.6 6.8 1.1 13 4.6 6.1 1.1 9.9 3.4 309 10 288 165 -1.3 0.2 -0.8 -1.4 02/24/2006 14:30:00 6.6 1 9.1 3.4 6.4 1 9.5 3.8 6.2 1 8.8 3.8 321 15 316 165 -1 0 -0.8 -1.2 02/24/2006 14:40:00 6.5 0.9 10.3 4.6 6.4 0.9 9.9 4.2 6 1 8.8 3.4 316 15 302 165 -1 0 -0.8 -1.2 02/24/2006 14:50:00 7.4 1 10.3 4.9 7.3 1 10.3 4.9 6.2 1.2 9.9 3.8 302 8 301 165 -1.3 0.1 -1 -1.4 02/24/2006 15:00:00 7.1 0.8 9.5 4.2 7 0.8 9.5 3.8 6.3 0.8 8.4 4.2 311 9 314 165 -1.2 0 -1 -1.4 02/24/2006 15:10:00 7.1 0.8 9.5 4.9 7 0.8 9.9 4.9 6.1 1 10.3 3.8 310 9 312 165 -1.1 0.1 -0.8 -1.4 02/24/2006 15:20:00 6.3 0.9 8.8 3.8 6.2 0.9 9.1 3.4 6.3 0.9 8.4 4.2 325 9 329 165 -0.9 0.1 -0.5 -1.2 02/24/2006 15:30:00 6.3 1 8.8 4.2 6.2 1 8.4 4.2 5.9 1 8.4 3.8 315 11 295 165 -0.9 0.2 -0.5 -1.2 02/24/2006 15:40:00 5.6 0.7 7.6 3.4 5.3 0.7 7.2 3 5.4 0.7 6.8 3.4 330 17 347 165 -0.9 0.1 -0.5 -1.2 02/24/2006 15:50:00 5.4 1.1 7.6 2.6 5 1.1 7.6 2.6 5.2 1 7.2 2.6 335 17 341 165 -0.5 0 -0.3 -0.5 02/24/2006 16:00:00 5.8 1 8.4 2.6 5.7 0.9 8 2.6 5.2 1 7.6 2.6 325 20 309 165 -0.8 0.1 -0.5 -1 02/24/2006 16:10:00 5.6 0.9 8.8 3.8 5.5 1 8.8 3 5.4 1 8 3 334 15 332 165 -0.6 0 -0.3 -1 02/24/2006 16:20:00 6.2 1.2 9.5 3.4 6 1.2 9.5 3 6.2 1.2 9.5 3.8 331 12 338 165 -0.8 0.1 -0.5 -1 02/24/2006 16:30:00 4.4 0.7 6.1 2.3 4.3 0.7 6.1 2.6 3.7 0.8 6.1 1.5 309 11 322 165 -1 0.1 -0.8 -1.4 02/24/2006 16:40:00 4.3 0.7 5.7 2.3 4.2 0.7 5.7 2.3 3.8 0.6 5.3 2.3 312 9 308 165 -0.9 0 -0.8 -1.2 02/24/2006 16:50:00 4.3 0.6 6.8 2.6 4.3 0.6 6.5 2.6 3.4 0.7 5.3 1.9 302 9 297 165 -1.3 0 -1 -1.4 02/24/2006 17:00:00 5.2 0.6 6.8 3.4 5.1 0.6 6.5 3 4.4 0.6 5.7 3 305 10 282 165 -1.5 0 -1.2 -1.7 02/24/2006 17:10:00 4.4 0.8 6.8 3 4.3 0.8 6.8 2.3 4.2 0.7 6.1 1.9 323 13 313 165 -1.4 0.1 -1.2 -1.7 02/24/2006 17:20:00 4.8 0.7 6.8 3 4.7 0.7 6.8 3 4 0.8 6.8 2.3 308 12 319 165 -1.7 0.2 -1.2 -1.9 02/24/2006 17:30:00 5.5 1.2 9.1 2.6 5.5 1.2 9.1 2.6 4.9 1.3 9.5 1.9 316 13 329 165 -2 0 -1.9 -2.1 02/24/2006 17:40:00 5.3 1 7.6 3 5 1 7.6 2.6 5.2 1.1 8.8 3.4 338 15 327 165 -2.1 0 -1.9 -2.4 02/24/2006 17:50:00 4.6 0.7 6.1 2.3 4.4 0.7 5.7 2.3 4.3 0.7 6.1 2.6 331 15 3 165 -2.4 0 -2.1 -2.6 02/24/2006 18:00:00 4.2 0.5 6.5 3 4.1 0.5 6.5 3 4.1 0.5 6.1 3.4 328 8 341 165 -2.8 0.1 -2.6 -3 02/24/2006 18:10:00 4.5 0.5 5.7 2.6 4.4 0.5 5.7 2.6 4.1 0.6 5.3 2.6 315 6 313 165 -3.2 0 -2.8 -3.5 02/24/2006 18:20:00 4.1 0.7 5.7 2.6 4 0.7 5.3 2.6 3.6 0.6 5.3 2.3 316 10 310 165 -3.3 0 -3 -3.5 02/24/2006 18:30:00 5.1 1.3 8.4 2.3 4.5 1.3 8 2.6 4.7 1.3 8 2.3 345 13 342 165 -3.2 0.1 -3 -3.5 02/24/2006 18:40:00 2.9 0.9 4.9 0.7 2.3 0.9 4.6 0.4 2.8 0.7 4.6 0.7 352 12 353 165 -3.2 0 -3 -3.5 02/24/2006 18:50:00 2.3 0.5 3.4 0.7 2.2 0.5 3.4 0.7 2.1 0.4 3.4 1.1 326 22 356 165 -3.2 0 -3 -3.3 02/24/2006 19:00:00 2.5 1.2 5.7 0.4 2.6 1.2 5.3 0.7 2.2 0.8 4.6 0.4 293 29 296 165 -3.2 0.1 -2.8 -3.5 02/24/2006 19:10:00 4.1 0.9 6.1 1.9 4.2 0.9 6.1 2.3 3.6 0.7 5.7 1.9 307 11 303 165 -3.2 0 -2.8 -3.5 02/24/2006 19:20:00 4.3 0.6 5.7 2.6 4.3 0.6 5.7 2.6 3.5 0.6 5.7 2.3 303 7 292 165 -3.1 0.1 -2.8 -3.3 02/24/2006 19:30:00 4.4 0.9 7.2 1.9 4.5 0.9 7.2 1.9 3.7 0.8 6.1 1.5 305 12 302 165 -3 0.1 -2.6 -3.3 02/24/2006 19:40:00 4.9 0.6 6.5 3.4 4.9 0.6 6.1 3.4 3.8 0.6 5.7 2.3 299 5 308 165 -3.2 0.1 -2.8 -3.5 02/24/2006 19:50:00 3.8 0.6 5.3 2.3 3.8 0.6 5.3 2.6 3.3 0.5 4.9 2.3 309 6 301 165 -3.5 0.1 -3.3 -3.5 02/24/2006 20:00:00 3.4 0.5 4.6 2.3 3.4 0.5 4.9 1.9 2.9 0.5 4.6 1.9 306 7 297 165 -3.5 0 -3.3 -3.7 02/24/2006 20:10:00 3 0.6 4.6 1.5 2.9 0.6 4.9 1.5 2.4 0.4 3.8 1.1 304 9 303 165 -3.5 0 -3.3 -3.5 02/24/2006 20:20:00 2.6 0.5 3.8 1.5 2.6 0.5 3.8 1.5 2.3 0.5 4.2 1.1 309 11 309 165 -3.3 0 -3.3 -3.5 02/24/2006 20:30:00 2.6 0.4 3.4 1.5 2.6 0.4 3.4 1.5 2.1 0.4 3 1.1 301 9 300 165 -3.5 0.1 -3.3 -3.5 02/24/2006 20:40:00 2.1 0.4 3 1.1 2.2 0.4 3 1.1 1.7 0.4 3 0.7 297 7 302 165 -3.6 0 -3.5 -3.7 02/24/2006 20:50:00 2 0.4 3 0.7 2 0.4 3 0.7 1.6 0.4 2.6 0.7 299 7 293 165 -3.7 0.1 -3.3 -3.9 02/24/2006 21:00:00 2.6 0.3 3.4 1.9 2.6 0.3 3.4 1.9 2.2 0.5 3.8 0.7 295 6 281 165 -3.6 0 -3.5 -3.5 02/24/2006 21:10:00 2.2 0.8 4.2 0.4 2 1 4.2 0.4 1.9 0.6 3.4 0.4 309 17 291 165 -3.5 0.1 -3.3 -3.9 02/24/2006 21:20:00 1.6 0.4 2.6 0.7 1.2 0.5 2.6 0.4 1.4 0.3 2.3 0.7 301 13 309 165 -3.5 0.1 -3.3 -3.9 02/24/2006 21:30:00 1.9 0.5 2.6 0.7 1.7 0.6 2.6 0.4 1.7 0.5 2.6 0.7 291 9 277 165 -3.3 0 -3.3 -3.5 02/24/2006 21:40:00 2 0.5 3.4 0.7 1.8 0.7 3.4 0.4 1.8 0.5 3 0.7 298 11 299 165 -3.4 0 -3.3 -3.5 02/24/2006 21:50:00 2.3 0.5 3 1.1 2.1 0.5 3 0.7 2 0.5 3 1.1 306 5 303 165 -3.5 0.1 -3.3 -3.5 02/24/2006 22:00:00 2.1 0.4 3 0.7 2 0.5 3 0.4 1.8 0.4 2.6 0.7 303 6 307 165 -3.5 0 -3.5 -3.7 02/24/2006 22:10:00 1.5 0.6 2.6 0.4 1.2 0.8 2.6 0.4 1.4 0.4 2.3 0.4 321 13 301 165 -3.5 0 -3.3 -3.5 02/24/2006 22:20:00 1 0.5 2.3 0.4 0.6 0.4 2.3 0.4 1.1 0.4 2.3 0.4 350 13 335 165 -3.5 0.1 -3.3 -3.5 02/24/2006 22:30:00 0.7 0.4 1.5 0.4 0.4 0 0.7 0.4 0.7 0.4 1.5 0.4 353 6 337 165 -3.7 0 -3.5 -3.9 02/24/2006 22:40:00 0.4 0.2 1.1 0.4 0.4 0 0.4 0.4 0.5 0.3 1.5 0.4 112 76 145 165 -3.7 0 -3.5 -3.9 02/24/2006 22:50:00 0.4 0.1 0.7 0.4 0.4 0 0.4 0.4 0.4 0.2 1.1 0.4 133 0 133 165 -4 0.1 -3.5 -4.2 02/24/2006 23:00:00 0.7 0.3 1.1 0.4 0.4 0 0.4 0.4 0.7 0.2 1.1 0.4 133 0 133 165 -3.8 0.1 -3.5 -4.2 02/24/2006 23:10:00 1 0.3 1.5 0.4 0.4 0 0.4 0.4 0.8 0.3 1.5 0.4 144 14 133 165 -3.6 0 -3.5 -3.7 02/24/2006 23:20:00 1.4 0.2 1.9 1.1 1 0.3 1.5 0.4 1.4 0.2 1.9 1.1 139 7 152 165 -3.5 0 -3.3 -3.5 02/24/2006 23:30:00 1.1 0.4 1.9 0.4 0.8 0.4 1.5 0.4 1.2 0.4 1.9 0.4 135 9 126 165 -3.5 0 -3.3 -3.5 02/24/2006 23:40:00 0.8 0.3 1.5 0.4 0.4 0 0.7 0.4 0.8 0.3 1.5 0.4 168 8 171 165 -3.7 0.1 -3.3 -3.9 02/24/2006 23:50:00 0.9 0.5 1.9 0.4 0.5 0.3 1.5 0.4 0.9 0.5 1.9 0.4 165 0 163 165 -3.8 0 -3.5 -3.9 02/25/2006 00:00:00 0.4 0.2 1.1 0.4 0.4 0 0.4 0.4 0.4 0.1 1.1 0.4 172 19 226 165 -4 0.2 -3.7 -4.4 02/25/2006 00:10:00 1.5 0.5 2.3 0.4 1.1 0.7 2.3 0.4 1.4 0.6 2.3 0.4 239 7 242 165 -3.6 0.4 -3 -4.4 02/25/2006 00:20:00 1.9 0.2 2.3 1.1 1.8 0.2 2.3 1.1 2 0.2 2.6 1.5 231 4 242 165 -3 0 -2.8 -3.3 02/25/2006 00:30:00 1.9 0.2 2.3 1.5 1.8 0.2 2.3 1.5 2 0.2 2.3 1.5 231 1 231 165 -3.1 0 -3 -3.3 02/25/2006 00:40:00 1.7 0.2 2.3 1.1 1.5 0.2 1.9 1.1 1.8 0.2 2.3 1.5 242 5 246 165 -3.1 0 -3 -3.3 02/25/2006 00:50:00 1.3 0.5 2.6 0.4 1.1 0.6 2.6 0.4 1.5 0.6 2.6 0.4 188 35 200 165 -3.4 0.1 -3 -3.5 02/25/2006 01:00:00 1.3 0.8 2.6 0.4 1 0.7 2.6 0.4 1.2 0.7 2.6 0.4 151 8 139 165 -3.8 0 -3.5 -3.9 02/25/2006 01:10:00 1.8 0.4 2.6 0.7 1.5 0.4 2.3 0.4 1.7 0.5 2.6 0.4 150 12 139 165 -3.7 0 -3.5 -3.9 02/25/2006 01:20:00 1.6 0.3 1.9 1.1 1.5 0.3 1.9 0.7 1.6 0.2 2.3 1.1 145 9 159 165 -3.7 0 -3.5 -3.9 02/25/2006 01:30:00 1.8 0.2 2.3 1.5 1.6 0.2 2.3 1.1 1.8 0.2 2.3 1.5 153 13 144 165 -4 0.1 -3.9 -4.2 02/25/2006 01:40:00 0.9 0.6 2.3 0.4 0.8 0.6 1.9 0.4 1 0.6 2.3 0.4 165 1 164 165 -3.8 0.1 -3.5 -4.2 02/25/2006 01:50:00 0.8 0.3 1.5 0.4 0.5 0.3 1.5 0.4 0.7 0.2 1.1 0.4 208 23 222 165 -3.5 0 -3.3 -3.9 02/25/2006 02:00:00 1.1 0.5 1.9 0.4 1 0.5 1.9 0.4 1 0.6 2.3 0.4 193 27 203 165 -3.4 0 -3.3 -3.5 02/25/2006 02:10:00 0.8 0.4 1.9 0.4 0.9 0.4 1.9 0.4 0.9 0.4 1.5 0.4 265 14 243 165 -3.5 0 -3.3 -3.5 02/25/2006 02:20:00 0.7 0.5 1.9 0.4 0.7 0.5 1.9 0.4 0.8 0.5 1.9 0.4 263 82 164 165 -3.2 0 -3 -3.5 02/25/2006 02:30:00 1.9 0.4 2.6 1.1 1.8 0.4 2.6 0.7 2 0.4 2.6 1.1 173 5 165 165 -3.5 0 -3.3 -3.5 02/25/2006 02:40:00 1.9 0.4 2.6 1.1 1.8 0.3 2.3 1.1 2.1 0.3 2.6 1.5 172 4 172 165 -3.3 0 -3 -3.5 02/25/2006 02:50:00 2 0.2 2.3 1.5 1.9 0.2 2.3 1.5 2.1 0.2 2.6 1.5 180 2 178 165 -3.1 0 -3 -3.3 02/25/2006 03:00:00 2.2 0.2 2.6 1.5 2.1 0.2 2.6 1.5 2.3 0.3 3 1.5 181 3 182 165 -3 0 -2.8 -3.3 02/25/2006 03:10:00 1.5 0.3 2.3 0.7 1.4 0.3 1.9 0.4 1.4 0.3 2.3 0.7 182 5 165 165 -3 0.1 -2.8 -3.3 02/25/2006 03:20:00 1.4 0.2 1.9 0.7 1.2 0.3 1.9 0.7 1.3 0.3 1.9 0.7 171 6 184 165 -3.1 0 -2.8 -3.3 02/25/2006 03:30:00 1.4 0.2 1.9 1.1 1.2 0.2 1.9 0.7 1.4 0.2 1.9 0.7 174 1 173 165 -3.2 0.1 -3 -3.5 02/25/2006 03:40:00 1.7 0.3 2.3 1.1 1.6 0.3 2.3 1.1 1.9 0.3 2.6 1.5 165 2 165 165 -3.2 0.1 -2.8 -3.5 02/25/2006 03:50:00 1.7 0.2 2.3 1.1 1.6 0.2 2.3 1.1 1.8 0.2 2.3 1.5 162 4 158 165 -3.6 0 -3.5 -3.5 02/25/2006 04:00:00 1.5 0.2 1.9 0.7 1.3 0.3 1.9 0.7 1.5 0.2 1.9 1.1 168 4 164 165 -3.3 0 -3 -3.5 02/25/2006 04:10:00 1.3 0.2 1.9 0.7 1 0.3 1.5 0.4 1.2 0.2 1.9 0.7 168 2 172 165 -3.2 0 -3 -3.3 02/25/2006 04:20:00 1.9 0.3 2.6 1.5 1.8 0.3 2.3 1.1 1.9 0.3 2.3 1.5 173 2 177 165 -3.1 0 -2.8 -3.3 02/25/2006 04:30:00 2 0.4 2.6 0.7 1.9 0.4 2.6 0.7 1.9 0.3 2.6 1.1 174 3 172 165 -3.1 0 -2.8 -3.3 02/25/2006 04:40:00 1.3 0.2 1.9 0.7 1.2 0.3 1.9 0.7 1.4 0.2 2.3 1.1 173 2 174 165 -3.2 0 -3 -3.3 02/25/2006 04:50:00 2.5 0.5 3.4 1.5 2.4 0.5 3.4 1.5 2.6 0.4 3.4 1.9 156 5 158 165 -3.4 0.1 -3 -3.5 02/25/2006 05:00:00 2.5 0.5 3.4 1.1 2.5 0.5 3.4 1.1 2.7 0.4 3.4 1.5 152 3 153 165 -3.7 0 -3.5 -3.7 02/25/2006 05:10:00 1.8 0.2 2.3 1.5 1.7 0.2 2.3 1.1 1.9 0.2 2.3 1.1 170 6 165 165 -3.6 0 -3.5 -3.7 02/25/2006 05:20:00 1.6 0.3 2.3 1.1 1.4 0.3 2.3 0.7 1.6 0.3 2.3 1.1 186 5 184 165 -3.5 0 -3.3 -3.7 02/25/2006 05:30:00 1.5 0.2 1.9 1.1 1.3 0.2 1.9 0.7 1.5 0.2 1.9 1.1 187 8 197 165 -3.5 0 -3.3 -3.5 02/25/2006 05:40:00 1.1 0.4 1.9 0.4 1.2 0.4 2.3 0.4 1.5 0.4 2.3 0.7 194 12 206 165 -3.2 0.2 -2.8 -3.5 02/25/2006 05:50:00 1.5 0.4 2.3 0.7 1.6 0.5 2.6 0.7 1.7 0.5 2.6 0.7 211 30 253 165 -3.1 0 -2.8 -3.3 02/25/2006 06:00:00 2.2 0.3 3 1.5 2.4 0.3 3 1.5 2.4 0.3 3 1.5 212 39 150 165 -2.5 0.3 -2.1 -3.3 02/25/2006 06:10:00 2.2 0.3 3 1.5 2.2 0.2 3 1.5 2.3 0.3 3 1.5 188 14 169 165 -3 0.1 -2.6 -3 02/25/2006 06:20:00 2.4 0.3 3 1.9 2.4 0.3 3 1.9 2.5 0.4 3.4 1.9 194 6 195 165 -2.9 0.1 -2.6 -3 02/25/2006 06:30:00 2.3 0.2 2.6 1.9 2.2 0.2 2.6 1.9 2.3 0.2 2.6 1.9 194 6 199 165 -2.6 0 -2.6 -2.8 02/25/2006 06:40:00 1.5 0.4 2.3 0.7 1.2 0.5 2.3 0.4 1.4 0.4 2.3 0.7 174 3 178 165 -3 0.1 -2.8 -3 02/25/2006 06:50:00 1.5 0.2 1.9 0.7 1.1 0.3 1.9 0.4 1.5 0.3 1.9 0.7 177 9 165 165 -2.9 0 -2.8 -3.3 02/25/2006 07:00:00 1.2 0.3 1.9 0.4 0.8 0.4 1.5 0.4 1.3 0.3 2.3 0.7 176 8 183 165 -2.7 0 -2.6 -3 02/25/2006 07:10:00 1 0.5 1.9 0.4 0.9 0.5 1.9 0.4 1.4 0.5 2.3 0.4 211 30 184 165 -2.3 0.2 -1.9 -2.8 02/25/2006 07:20:00 1.8 0.8 2.6 0.4 1.9 0.8 3 0.4 2 0.6 3 0.7 196 12 201 165 -2.2 0 -2.1 -2.6 02/25/2006 07:30:00 1.5 0.3 2.3 0.7 1.4 0.4 2.3 0.4 1.7 0.2 2.3 1.1 175 12 196 165 -2.7 0 -2.4 -2.8 02/25/2006 07:40:00 1.8 0.5 3 1.1 1.7 0.5 2.6 0.7 1.8 0.3 2.6 1.1 177 17 196 165 -2.6 0.1 -2.4 -3 02/25/2006 07:50:00 2.2 0.5 3 1.1 2.1 0.5 3 0.7 2.3 0.4 3 1.5 170 11 164 165 -2.4 0 -2.1 -2.6 02/25/2006 08:00:00 2.5 0.3 3.4 1.5 2.3 0.3 3 1.5 2.4 0.4 3.4 1.5 176 8 170 165 -2.1 0 -1.9 -2.1 02/25/2006 08:10:00 2.6 0.5 3.4 1.5 2.5 0.4 3.4 1.5 2.6 0.5 3.4 1.5 199 2 197 165 -1.9 0 -1.7 -2.1 02/25/2006 08:20:00 2.4 0.5 3.8 1.5 2.3 0.6 3.8 1.5 2.5 0.5 4.2 1.5 189 5 200 165 -1.9 0 -1.7 -1.9 02/25/2006 08:30:00 3.4 0.3 4.2 2.6 3.4 0.3 4.2 2.6 3.7 0.3 4.6 3 191 7 187 165 -1.4 0.2 -1.2 -1.9 02/25/2006 08:40:00 3.9 0.4 4.6 3 3.7 0.4 4.6 2.6 3.8 0.5 4.9 2.6 181 3 183 165 -1.6 0.1 -1.2 -1.9 02/25/2006 08:50:00 4.4 0.4 5.3 3.4 4.3 0.4 4.9 3.4 4.4 0.4 4.9 3 188 6 186 165 -1.8 0.2 -1.4 -2.1 02/25/2006 09:00:00 4 0.4 4.9 3 4 0.3 4.9 3 3.8 0.4 4.9 2.6 203 6 213 165 -1.4 0.1 -1.2 -1.4 02/25/2006 09:10:00 4.2 0.4 4.9 3 4.2 0.4 5.3 3 4.2 0.5 5.3 3 202 5 202 165 -1.3 0 -1 -1.7 02/25/2006 09:20:00 2.8 0.5 4.2 1.5 2.9 0.5 4.2 1.5 3 0.4 3.8 1.5 204 9 203 165 -0.9 0.1 -0.5 -1.2 02/25/2006 09:30:00 1.5 0.8 3 0.4 1.6 0.9 3 0.4 1.8 0.8 3.4 0.4 216 13 198 165 -0.7 0 -0.5 -0.8 02/25/2006 09:40:00 1.2 0.5 2.6 0.4 1.1 0.5 2.6 0.4 1.5 0.4 3 0.7 183 22 169 165 -0.6 0.1 -0.5 -0.8 02/25/2006 09:50:00 2.3 0.8 4.2 0.4 2.3 0.8 4.2 0.4 2.7 0.6 4.2 1.5 195 14 197 165 -0.8 0 -0.5 -0.8 02/25/2006 10:00:00 2.8 1.1 5.7 0.7 3 1.1 5.7 0.7 2.9 1 5.7 0.4 229 26 243 165 -0.6 0 -0.5 -1 02/25/2006 10:10:00 3.7 0.7 5.7 2.3 3.8 0.7 6.1 2.6 3.7 0.6 5.7 2.6 214 11 225 165 -0.3 0 -0.3 -0.5 02/25/2006 10:20:00 4.4 0.6 6.1 1.9 4.6 0.6 6.1 2.6 4.4 0.8 6.1 2.3 224 12 221 165 -0.3 0 -0.3 -0.5 02/25/2006 10:30:00 3.2 1.1 5.7 0.4 3.3 1.1 5.7 0.4 3.3 1.1 5.7 1.1 220 18 231 165 -0.4 0.1 -0.1 -0.8 02/25/2006 10:40:00 4 0.7 6.8 2.6 4 0.7 6.8 2.6 3.8 0.7 6.5 2.3 227 11 245 165 -0.6 0 -0.5 -0.8 02/25/2006 10:50:00 3.8 0.8 5.7 1.9 3.9 0.8 6.1 1.9 3.9 0.9 6.5 2.3 221 15 249 165 0.3 0.2 0.9 -0.5 02/25/2006 11:00:00 2.8 1.2 5.7 0.4 2.7 1.2 5.7 0.4 2.9 1.1 5.3 0.4 201 27 181 165 0.1 0 0.4 -0.1 02/25/2006 11:10:00 4.5 0.8 6.5 2.6 4.4 0.8 6.5 2.6 4.3 0.8 6.5 2.3 179 11 195 165 0 0.2 0.4 -0.3 02/25/2006 11:20:00 4 1 6.5 1.9 3.9 1 6.1 1.5 3.9 1 6.1 1.1 192 17 198 165 0 0 0.2 -0.3 02/25/2006 11:30:00 3.1 1.5 6.5 0.4 3 1.5 6.1 0.4 3.3 1.4 6.5 0.4 174 66 157 165 -0.2 0.1 0.2 -0.5 02/25/2006 11:40:00 2.2 1.2 5.7 0.4 2.2 1.1 5.7 0.4 2.6 1 4.9 0.4 180 28 164 165 0.2 0 0.7 -0.1 02/25/2006 11:50:00 2.4 1.5 6.5 0.4 2.3 1.5 6.5 0.4 2.6 1.3 6.1 0.4 156 41 133 165 0.2 0 0.7 -0.1 02/25/2006 12:00:00 2.7 1.7 6.5 0.4 2.7 1.7 6.8 0.4 3 1.3 6.8 1.1 217 49 291 165 0.8 0.1 1.1 0.2 02/25/2006 12:10:00 1.5 1.1 4.6 0.4 1.5 1.2 4.9 0.4 1.9 1 5.3 0.4 200 86 278 165 0.8 0.1 0.9 0.7 02/25/2006 12:20:00 4.5 1.7 9.9 0.4 4.7 1.7 9.9 0.4 4.5 1.7 9.9 0.7 291 24 276 165 1 0 1.4 0.7 02/25/2006 12:30:00 6.5 1.2 8.8 3.4 6.5 1.2 9.5 3.4 5.6 1.1 8.4 3 300 11 303 165 0.8 0 1.1 0.7 02/25/2006 12:40:00 6.6 0.9 9.1 4.6 6.7 0.9 9.1 4.6 6 1.1 9.1 3.4 289 8 286 165 0.5 0.1 0.7 0.2 02/25/2006 12:50:00 5.7 1 8 3.4 5.9 1 8.4 3.8 5.6 0.9 8 3.8 280 7 272 165 0.4 0 0.7 0.2 02/25/2006 13:00:00 5.2 1 7.6 3 5.6 1 8 3 5.3 1 8 2.6 276 7 284 165 0.5 0 0.7 0.4 02/25/2006 13:10:00 4.8 1 7.2 2.6 5.4 1 8 2.6 5.2 0.9 7.2 2.6 269 16 282 165 0.7 0.1 0.9 0.7 02/25/2006 13:20:00 2.9 0.7 4.6 1.1 3.5 0.7 5.3 1.1 3.2 0.8 4.9 1.1 253 12 242 165 0.7 0 0.9 0.7 02/25/2006 13:30:00 1.7 1.2 4.6 0.4 1.8 1.3 4.6 0.4 2 1 4.6 0.4 225 29 237 165 0.9 0 1.1 0.9 02/25/2006 13:40:00 1.2 0.6 2.6 0.4 1.2 0.7 3.4 0.4 1.6 0.6 3.4 0.4 208 56 267 165 0.8 0 0.9 0.7 02/25/2006 13:50:00 2.2 1.3 6.1 0.4 2.3 1.3 6.1 0.4 2.4 1 5.3 0.7 217 79 322 165 0.8 0 1.4 0.7 02/25/2006 14:00:00 2 1.1 4.9 0.4 2.1 1.1 4.9 0.4 2.5 0.9 4.9 0.4 172 72 282 165 1.2 0.2 1.6 0.9 02/25/2006 14:10:00 2.4 0.7 4.2 0.7 2.4 0.7 4.2 0.7 2.7 0.7 4.6 1.5 126 28 100 165 0.7 0 0.9 0.4 02/25/2006 14:20:00 1.9 0.8 4.6 0.4 1.9 0.8 4.6 0.4 2.4 0.5 3.4 0.7 132 43 63 165 0.7 0 0.9 0.4 02/25/2006 14:30:00 1.5 0.7 3 0.4 1.5 0.6 3 0.4 2.2 0.6 4.2 0.4 152 39 158 165 0.7 0 0.9 0.7 02/25/2006 14:40:00 1 0.7 3 0.4 1 0.7 3 0.4 1.5 0.7 3.4 0.4 173 45 196 165 0.7 0 0.9 0.7 02/25/2006 14:50:00 2.1 1.1 5.7 0.4 2.3 1.2 6.5 0.4 2.4 0.8 4.9 0.7 230 45 273 165 1.4 0.3 1.8 0.9 02/25/2006 15:00:00 3.9 2 8.8 0.4 4.5 2.3 9.5 0.4 4.3 2.3 9.9 0.4 264 17 273 165 2.1 0.2 2.6 1.6 02/25/2006 15:10:00 5.1 1.1 8.4 1.9 5.9 1 8.4 2.3 5.8 1 7.6 3 270 8 276 165 2.4 0 2.6 2.1 02/25/2006 15:20:00 4.4 1.4 8.4 1.5 4.8 1.3 8 2.3 4.7 1.3 8.4 2.3 267 12 277 165 2.5 0 2.8 2.3 02/25/2006 15:30:00 4.1 1.3 7.6 1.5 4.7 1.1 7.6 2.6 4.5 1.1 8 2.3 271 13 287 165 2.7 0 2.8 2.8 02/25/2006 15:40:00 8.7 2.7 14.9 3.4 8.9 2.5 15.3 4.2 8.2 2.3 14.5 4.2 291 18 289 165 2.9 0 3 2.8 02/25/2006 15:50:00 12 1.6 17.6 8.4 11.9 1.7 17.2 8 10.3 1.6 14.1 6.8 303 10 308 165 3 0 3.3 2.8 02/25/2006 16:00:00 14.4 1.6 18.7 10.3 14.3 1.6 18.3 9.9 11.1 1.7 16.8 7.6 302 7 299 165 2.9 0 3 2.8 02/25/2006 16:10:00 15.2 1.3 19.5 11.1 15.2 1.3 19.1 10.3 11.7 1.7 15.6 8.4 297 8 302 165 2.6 0.1 2.8 2.6 02/25/2006 16:20:00 14.9 1.2 18.7 11.5 14.9 1.2 18.7 11.5 11.7 1.6 16.8 8.4 302 7 300 165 2.4 0 2.6 2.3 02/25/2006 16:30:00 15.3 1.7 21.4 10.3 15.3 1.7 21.4 9.9 12.5 2.3 19.1 8 303 8 295 165 2.3 0 2.6 2.1 02/25/2006 16:40:00 16.3 1.7 20.2 12.6 16.3 1.7 19.9 12.2 13 1.6 16.8 9.1 300 7 300 165 2 0 2.3 1.8 02/25/2006 16:50:00 15.8 1.9 21 11.5 15.7 1.9 20.6 11.5 13 1.9 19.5 8 304 8 310 165 1.8 0 1.8 1.6 02/25/2006 17:00:00 14.8 1.8 19.1 8.4 14.8 1.8 19.1 9.1 12.1 1.6 16.8 8.4 302 8 301 165 1.5 0.1 1.8 1.4 02/25/2006 17:10:00 13.5 2.6 19.1 7.6 13.4 2.6 19.1 8.4 10.8 2.4 17.6 5.7 302 9 297 165 1.3 0 1.6 1.1 02/25/2006 17:20:00 9.9 1.9 14.1 5.3 9.8 1.8 14.1 5.3 8.3 1.7 14.1 3.4 303 10 305 165 1 0.1 1.4 0.9 02/25/2006 17:30:00 9 1.9 13.3 5.3 9 1.8 13.3 4.9 7.6 1.7 12.2 3.8 306 12 293 165 0.7 0 0.9 0.4 02/25/2006 17:40:00 9.6 1.6 14.1 4.9 9.5 1.5 13.7 4.9 8.1 1.6 12.2 3.8 306 11 288 165 0.3 0.1 0.7 0.2 02/25/2006 17:50:00 9.7 1.2 12.2 4.6 9.6 1.1 12.2 6.5 8.1 1.2 11.8 4.9 305 10 304 165 -0.1 0 0.2 -0.3 02/25/2006 18:00:00 12.1 1.9 17.2 6.5 12 1.8 17.2 6.5 10.7 1.8 17.2 6.5 310 8 312 165 -0.3 0 -0.1 -0.5 02/25/2006 18:10:00 12.4 1.5 16.1 8.8 12.3 1.5 16.1 8 10.1 1.4 14.5 6.5 305 9 307 165 -0.4 0 -0.3 -0.5 02/25/2006 18:20:00 12.9 2 18.3 8 12.8 1.9 18.3 7.6 10.3 1.5 14.5 7.2 300 8 297 165 -0.5 0 -0.3 -0.8 02/25/2006 18:30:00 14.8 1.7 18.7 10.3 14.7 1.7 18.7 10.7 12 1.8 17.6 7.6 301 8 295 165 -0.5 0 -0.3 -0.8 02/25/2006 18:40:00 14.5 2.8 20.2 8.8 14.4 2.9 20.2 8.4 11.7 2.1 17.9 6.8 304 8 293 165 -0.6 0 -0.5 -0.8 02/25/2006 18:50:00 14 2.4 21.4 8.8 13.9 2.4 20.6 8.4 12.1 2.4 18.7 6.8 307 10 297 165 -0.8 0 -0.5 -1 02/25/2006 19:00:00 10.9 2 15.6 6.1 10.8 1.9 15.3 6.1 9.2 1.7 14.5 3.8 305 12 290 165 -0.9 0 -0.8 -1.2 02/25/2006 19:10:00 9.5 1.3 13.3 6.5 9.5 1.3 13.7 6.5 7.9 1.3 11.8 4.6 300 12 298 165 -1 0 -1 -1.2 02/25/2006 19:20:00 7.7 1.7 12.2 3.8 7.6 1.7 11.8 3.4 6.8 1.7 11.5 2.6 304 15 312 165 -1.1 0 -1 -1.2 02/25/2006 19:30:00 6.7 1.3 10.7 4.2 6.7 1.2 10.3 3.4 5.7 1.2 9.9 2.6 301 14 330 165 -1.4 0 -1.2 -1.4 02/25/2006 19:40:00 8.1 1.3 12.6 5.7 8.1 1.3 12.2 5.3 7.2 1.5 11.8 3.8 300 12 287 165 -1.3 0 -1.2 -1.4 02/25/2006 19:50:00 8.7 1.6 11.8 4.6 8.7 1.5 12.2 4.6 7.4 1.5 11.5 3.8 303 11 294 165 -1.5 0 -1.2 -1.7 02/25/2006 20:00:00 9.9 1.6 14.1 6.1 9.8 1.6 14.1 5.3 8.6 1.5 13.3 5.3 306 10 302 165 -1.4 0 -1.2 -1.7 02/25/2006 20:10:00 9.8 1.3 13 6.1 9.7 1.3 13.3 6.1 8.6 1.5 12.2 5.3 305 11 295 165 -1.6 0 -1.4 -1.7 02/25/2006 20:20:00 7.6 1.1 10.3 4.2 7.5 1.1 10.3 3.8 7.1 1.1 10.7 4.2 314 9 323 165 -1.6 0 -1.4 -1.9 02/25/2006 20:30:00 9.5 1.7 13.7 4.9 9.5 1.7 13.7 4.9 8.5 1.5 12.2 4.9 311 8 300 165 -1.8 0 -1.7 -1.9 02/25/2006 20:40:00 9.9 1.5 14.1 6.1 9.8 1.5 14.1 6.5 9 1.7 13.3 4.9 313 9 318 165 -1.9 0.1 -1.7 -2.1 02/25/2006 20:50:00 10.7 1.3 13.7 7.6 10.6 1.3 13.7 7.6 9.9 1.3 13.7 6.1 315 8 318 165 -2 0 -1.9 -2.1 02/25/2006 21:00:00 9.6 1.3 13.3 4.9 9.5 1.3 13 4.9 9.5 1.3 13 5.7 327 9 325 165 -2.1 0 -1.9 -2.4 02/25/2006 21:10:00 11.9 1.3 14.1 8.8 11.7 1.3 14.5 8 11.6 1.3 14.5 8.4 326 7 339 165 -2.1 0 -1.9 -2.4 02/25/2006 21:20:00 11.2 1.4 14.9 7.6 11 1.4 15.3 8 11 1.5 15.3 8 328 9 337 165 -2 0 -1.9 -2.1 02/25/2006 21:30:00 12.2 1.5 16.4 8 12.1 1.5 16.1 7.6 12 1.5 16.8 8 327 9 318 165 -1.8 0 -1.7 -1.9 02/25/2006 21:40:00 13.8 1.5 18.7 11.1 13.6 1.6 18.7 10.7 13.4 1.6 18.3 9.9 327 9 315 165 -1.7 0 -1.4 -1.9 02/25/2006 21:50:00 13 1.3 16.8 9.1 12.8 1.3 16.8 8.8 12.5 1.5 17.2 8 319 8 318 165 -1.8 0.1 -1.4 -1.9 02/25/2006 22:00:00 13.6 1.6 17.6 9.9 13.4 1.7 17.2 9.5 13.4 1.7 17.6 9.1 323 7 325 165 -1.8 0 -1.7 -1.9 02/25/2006 22:10:00 13.5 1.7 17.2 8 13.3 1.7 17.2 7.6 12.9 1.7 16.8 8.8 324 11 328 165 -1.8 0 -1.7 -1.9 02/25/2006 22:20:00 13.9 2.3 19.5 8.8 13.8 2.3 19.5 8.4 13.3 2.2 17.6 8 321 10 306 165 -1.8 0 -1.7 -2.1 02/25/2006 22:30:00 14.1 1.8 19.5 9.9 14 1.8 19.1 9.5 13.7 1.7 19.1 9.5 321 9 305 165 -1.9 0 -1.7 -1.9 02/25/2006 22:40:00 15.6 2.2 20.6 10.7 15.5 2.2 21 10.3 15.2 2.3 19.9 9.9 321 7 315 165 -2 0 -1.9 -2.1 02/25/2006 22:50:00 16.7 1.7 21 12.6 16.6 1.7 20.6 12.6 16.3 1.7 19.9 10.3 316 6 318 165 -2.1 0 -1.9 -2.1 02/25/2006 23:00:00 17.7 1.1 19.9 14.5 17.6 1.2 19.9 14.5 17.1 1.3 20.2 13.7 315 5 317 165 -2.2 0 -2.1 -2.4 02/25/2006 23:10:00 17 1.4 20.2 12.6 16.9 1.4 20.2 11.8 16.3 1.7 20.6 10.7 318 7 314 165 -2.4 0 -2.1 -2.6 02/25/2006 23:20:00 17.9 1.5 21.4 13 17.8 1.5 20.6 13.3 17.4 1.6 21.4 13.3 318 6 316 165 -2.5 0 -2.4 -2.6 02/25/2006 23:30:00 17.4 1.9 21.8 13 17.2 1.9 21.4 12.6 16.9 1.9 22.1 12.2 322 8 319 165 -2.6 0 -2.6 -2.8 02/25/2006 23:40:00 19 1.4 22.6 14.9 18.8 1.4 22.1 14.9 18.9 1.5 22.6 14.9 324 7 318 165 -2.6 0 -2.6 -2.8 02/25/2006 23:50:00 18.5 1.6 22.1 14.5 18.4 1.6 22.1 14.5 18.3 1.7 22.9 12.6 321 6 317 165 -2.7 0 -2.6 -2.8 02/26/2006 00:00:00 17.7 1.4 21 13.7 17.6 1.4 21 13.3 17.3 1.5 20.6 12.6 319 6 312 165 -2.8 0 -2.6 -2.8 02/26/2006 00:10:00 17.8 1.4 21.4 13.3 17.6 1.5 21 13 17.5 1.5 20.6 13 322 7 323 165 -2.8 0 -2.6 -2.8 02/26/2006 00:20:00 17.2 1.4 20.6 13.7 17 1.4 20.6 13.3 17 1.7 21 12.2 324 7 318 165 -2.8 0 -2.6 -3 02/26/2006 00:30:00 17.2 1.3 20.6 13.3 17 1.3 20.6 13.7 16.8 1.3 20.6 12.2 323 7 326 165 -3 0 -2.8 -3 02/26/2006 00:40:00 18.9 1.5 22.9 13.7 18.8 1.5 22.6 14.1 18.7 1.6 22.9 12.6 318 7 312 165 -3 0 -2.8 -3.3 02/26/2006 00:50:00 20.4 1.7 24 16.8 20.3 1.7 23.7 16.4 19.5 1.7 23.7 15.6 313 5 307 165 -3 0 -2.8 -3.3 02/26/2006 01:00:00 19.8 1.4 22.9 14.9 19.7 1.4 23.3 14.9 18.3 1.8 23.3 14.1 312 6 316 165 -3 0 -2.8 -3.3 02/26/2006 01:10:00 18.8 1.3 22.6 14.9 18.7 1.3 22.6 14.5 17.9 1.5 22.1 14.1 315 6 312 165 -3.1 0 -3 -3.3 02/26/2006 01:20:00 18.9 1.3 21.8 15.6 18.8 1.3 22.1 14.9 18 1.3 21.4 14.9 315 6 309 165 -3.2 0 -3 -3.3 02/26/2006 01:30:00 17.4 1.5 20.6 12.6 17.2 1.5 20.6 13 16.8 1.8 20.6 11.8 321 8 318 165 -3.2 0 -3 -3.3 02/26/2006 01:40:00 17.1 1.6 20.2 11.8 17 1.5 20.2 12.2 16.8 1.8 20.6 11.5 321 7 311 165 -3.2 0 -3 -3.3 02/26/2006 01:50:00 15.5 1.4 19.9 11.8 15.4 1.5 19.5 11.5 15 1.5 19.5 10.7 319 8 311 165 -3.2 0 -3 -3.3 02/26/2006 02:00:00 14.9 1.6 18.7 10.7 14.7 1.6 18.7 10.7 14.2 1.5 17.9 10.3 317 8 307 165 -3.2 0 -3 -3.5 02/26/2006 02:10:00 14.3 1.7 18.3 10.3 14.1 1.7 17.9 10.3 13.9 1.7 18.3 10.3 322 8 312 165 -3.3 0 -3.3 -3.5 02/26/2006 02:20:00 15.8 1.7 20.6 12.2 15.6 1.7 20.2 11.5 15.1 1.7 20.2 9.9 317 8 317 165 -3.2 0 -3 -3.5 02/26/2006 02:30:00 14.9 1.5 18.7 11.5 14.7 1.5 18.7 11.8 14.3 1.8 19.1 8.8 317 6 313 165 -3.3 0 -3.3 -3.5 02/26/2006 02:40:00 15.6 1.6 20.2 11.5 15.5 1.6 20.6 11.1 14.4 1.8 17.9 9.5 313 7 301 165 -3.3 0 -3.3 -3.5 02/26/2006 02:50:00 15.8 1.5 19.1 11.5 15.7 1.5 18.7 11.5 13.5 1.7 17.9 8.8 309 6 310 165 -3.3 0 -3.3 -3.5 02/26/2006 03:00:00 15.2 1.5 19.1 11.1 15.1 1.5 19.1 11.5 13 1.7 17.6 8.8 307 7 297 165 -3.3 0 -3 -3.5 02/26/2006 03:10:00 14.2 1.2 17.6 11.5 14.1 1.2 17.6 11.5 11.4 1.6 15.6 7.6 302 8 307 165 -3.2 0 -3 -3.3 02/26/2006 03:20:00 13 1.2 16.4 9.9 12.9 1.2 16.4 10.3 10.6 1.4 14.9 7.6 303 7 305 165 -3.4 0 -3.3 -3.5 02/26/2006 03:30:00 14.1 0.9 16.4 11.8 14 1 16.1 11.8 11.1 1.6 17.2 8 299 7 295 165 -3.3 0 -3 -3.5 02/26/2006 03:40:00 17 1.7 21.4 12.6 17 1.7 21 12.6 13 1.7 17.6 9.5 298 6 299 165 -3.2 0 -3 -3.5 02/26/2006 03:50:00 18.4 1.7 22.1 11.8 18.4 1.7 22.6 12.6 14.4 2 20.6 10.7 296 6 298 165 -3.1 0 -2.8 -3.3 02/26/2006 04:00:00 17.4 1.3 20.6 13 17.4 1.4 21 13.3 13.2 1.9 19.9 9.5 296 6 291 165 -3 0 -2.8 -3 02/26/2006 04:10:00 17.2 1.5 20.2 13.3 17.2 1.5 20.6 13.7 13.8 2.2 19.9 9.9 293 5 295 165 -3 0 -2.8 -3.3 02/26/2006 04:20:00 15.8 1.5 19.5 11.5 15.8 1.6 19.5 11.5 12.4 1.7 19.1 8.4 298 6 293 165 -3 0 -2.8 -3.3 02/26/2006 04:30:00 15.9 1.3 19.5 12.2 15.9 1.3 19.9 12.6 12.2 1.8 17.6 8.4 294 6 292 165 -3 0 -2.8 -3.3 02/26/2006 04:40:00 16.5 1.6 20.2 11.8 16.5 1.6 21 11.1 13.6 2 21 8.8 292 4 286 165 -3 0 -2.8 -3 02/26/2006 04:50:00 15.6 1.3 18.7 12.6 15.6 1.4 18.7 12.2 12.5 2.2 19.1 8 293 5 290 165 -3 0 -2.8 -3.3 02/26/2006 05:00:00 15.2 1.2 18.3 11.1 15.2 1.3 18.3 11.1 11.8 1.6 16.8 8.8 295 6 301 165 -3 0 -2.8 -3 02/26/2006 05:10:00 14.8 1.4 18.3 10.3 14.8 1.5 18.3 10.3 12.1 2.1 18.7 8.4 294 7 284 165 -3 0 -2.8 -3.3 02/26/2006 05:20:00 16 1.5 19.1 11.5 16 1.5 19.5 11.1 13 2.3 19.1 8.4 292 5 290 165 -3 0 -2.8 -3 02/26/2006 05:30:00 15.5 1.2 18.7 12.6 15.6 1.2 18.7 12.2 12.1 1.7 17.2 8.4 293 6 291 165 -3 0 -2.8 -3 02/26/2006 05:40:00 15.7 1.7 19.5 11.8 15.6 1.7 19.1 11.5 12.2 1.5 17.6 8.4 300 6 298 165 -3 0 -2.8 -3 02/26/2006 05:50:00 14.9 1.3 19.1 11.5 14.8 1.3 19.1 11.5 11.6 1.6 18.3 8.8 299 8 297 165 -3.1 0 -2.8 -3.3 02/26/2006 06:00:00 15.5 1.5 19.5 11.1 15.4 1.5 19.5 11.5 11.9 1.5 15.6 8.8 300 6 300 165 -3 0 -2.8 -3.3 02/26/2006 06:10:00 15.5 1.2 18.7 12.2 15.5 1.2 18.7 11.8 12.6 1.9 17.2 8.4 300 7 283 165 -3 0 -2.8 -3.3 02/26/2006 06:20:00 14.2 1.1 17.6 11.1 14.1 1.1 16.8 10.7 10.9 1.7 16.4 8 300 7 292 165 -3 0 -2.8 -3.3 02/26/2006 06:30:00 14.9 1.1 19.1 11.8 14.8 1.2 19.1 11.5 11.5 1.6 16.4 7.6 297 7 289 165 -3 0 -2.8 -3 02/26/2006 06:40:00 13.5 1.3 17.6 10.3 13.5 1.3 17.6 9.9 10.8 1.8 16.1 7.6 296 7 285 165 -3 0 -2.8 -3.3 02/26/2006 06:50:00 12.9 1 16.1 9.1 12.8 1 16.4 9.1 10.8 1.5 14.5 7.6 306 8 294 165 -3.1 0 -3 -3.3 02/26/2006 07:00:00 14.8 1.7 18.7 11.8 14.7 1.7 18.7 11.5 13.3 2.2 19.1 8 311 6 310 165 -3 0 -2.8 -3.3 02/26/2006 07:10:00 14.4 1.4 18.3 11.5 14.3 1.5 17.9 10.7 12.7 1.7 17.2 8.4 310 6 310 165 -3 0 -2.8 -3.3 02/26/2006 07:20:00 12.4 1.7 16.1 9.1 12.4 1.7 15.6 8.8 11.6 1.8 15.6 7.6 311 6 308 165 -3 0 -2.8 -3 02/26/2006 07:30:00 12.6 1.7 16.8 8 12.5 1.7 16.8 8.8 10.7 1.8 17.6 7.2 305 7 304 165 -2.9 0 -2.6 -3.3 02/26/2006 07:40:00 11.1 1.1 14.5 8.4 11 1.2 14.5 8 9.1 1.4 13.7 6.1 306 7 301 165 -2.9 0 -2.8 -3 02/26/2006 07:50:00 12.4 1.5 16.4 9.1 12.3 1.5 16.4 9.1 10.6 1.5 15.3 7.2 308 8 292 165 -2.8 0 -2.6 -3 02/26/2006 08:00:00 12.4 1.4 15.6 8.4 12.3 1.4 15.6 8.4 11.5 1.7 16.1 7.6 312 8 310 165 -2.9 0 -2.6 -3 02/26/2006 08:10:00 14.4 1.7 18.7 10.7 14.3 1.7 18.7 10.7 11.8 2.2 18.3 7.6 307 7 313 165 -2.8 0 -2.6 -3 02/26/2006 08:20:00 13 1.8 19.5 9.1 12.9 1.8 19.1 8.8 11.9 2.3 19.9 7.2 312 8 314 165 -2.7 0 -2.6 -2.8 02/26/2006 08:30:00 14.6 1.9 20.2 10.3 14.5 1.9 19.9 10.7 12.3 1.7 16.1 8.4 307 6 293 165 -2.6 0 -2.6 -2.8 02/26/2006 08:40:00 14.4 1.7 19.5 10.7 14.3 1.7 19.1 11.1 13.1 1.9 17.2 7.6 310 6 304 165 -2.8 0 -2.6 -2.8 02/26/2006 08:50:00 14.9 1.8 19.1 11.1 14.7 1.8 19.1 11.1 13.1 1.9 17.9 9.1 308 9 307 165 -2.8 0 -2.6 -2.8 02/26/2006 09:00:00 14.4 1.7 19.1 9.5 14.4 1.7 18.7 9.1 12.5 2.1 19.5 7.6 309 8 305 165 -2.8 0 -2.6 -2.8 02/26/2006 09:10:00 13.5 1.5 16.8 9.5 13.4 1.5 17.2 9.5 12.7 1.7 16.1 8 313 6 307 165 -2.8 0 -2.6 -2.8 02/26/2006 09:20:00 13.4 1.5 18.3 9.5 13.3 1.5 17.6 9.5 12.2 1.9 16.4 8 311 7 312 165 -2.7 0 -2.6 -2.8 02/26/2006 09:30:00 13.2 1.3 16.4 9.1 13.1 1.3 16.1 9.5 11.8 1.7 15.6 6.5 310 6 307 165 -2.6 0 -2.6 -2.8 02/26/2006 09:40:00 14.2 1.5 17.6 10.3 14.1 1.5 17.6 10.7 12.9 1.7 17.2 8 311 6 307 165 -2.5 0 -2.4 -2.6 02/26/2006 09:50:00 13.6 1.2 17.6 9.9 13.5 1.2 17.2 9.1 11.9 1.5 15.6 6.5 309 7 301 165 -2.5 0 -2.6 -2.6 02/26/2006 10:00:00 15.4 1.2 18.7 13 15.3 1.2 18.7 12.6 13.7 1.8 17.9 9.5 310 5 313 165 -2.5 0 -2.4 -2.6 02/26/2006 10:10:00 15.9 1.7 20.2 11.1 15.7 1.7 20.2 11.1 14.1 2.1 19.1 8.4 310 6 306 165 -2.4 0 -2.1 -2.6 02/26/2006 10:20:00 15.2 1.7 19.5 10.7 15.1 1.7 19.5 11.1 13.5 1.8 17.6 8.4 310 5 310 165 -2.4 0 -2.1 -2.6 02/26/2006 10:30:00 15.1 1.5 19.1 11.5 15 1.5 19.1 11.5 13.1 1.9 18.3 8.4 309 6 310 165 -2.1 0 -1.9 -2.4 02/26/2006 10:40:00 13.5 1.7 17.9 9.5 13.5 1.7 17.6 9.5 11.9 2.4 19.5 6.8 308 10 312 165 -2 0 -1.9 -2.1 02/26/2006 10:50:00 15.9 1.5 19.1 11.8 15.8 1.4 18.7 11.8 13.8 1.6 17.9 9.9 310 7 307 165 -2 0 -1.9 -2.1 02/26/2006 11:00:00 14.1 1.5 19.1 10.3 14 1.6 19.1 9.9 12.2 2.4 19.1 6.8 309 8 313 165 -2 0 -1.9 -2.1 02/26/2006 11:10:00 13.6 1.3 16.8 8.8 13.4 1.3 16.4 8.8 11.5 1.5 15.3 7.6 308 7 308 165 -1.9 0 -1.7 -2.1 02/26/2006 11:20:00 13.4 1.6 19.1 9.1 13.3 1.6 18.3 9.5 12.2 2 17.6 7.2 312 8 318 165 -1.7 0 -1.4 -1.9 02/26/2006 11:30:00 12.7 1.7 16.4 7.2 12.6 1.7 16.8 7.6 11.4 1.7 16.4 7.2 311 8 310 165 -1.6 0 -1.4 -1.9 02/26/2006 11:40:00 14.7 1.9 18.7 9.1 14.6 2 19.1 9.1 12.8 2.1 19.1 7.6 309 6 308 165 -1.6 0 -1.4 -1.9 02/26/2006 11:50:00 13.3 1.7 17.2 9.5 13.1 1.7 17.2 9.5 11.8 2.1 16.1 7.2 309 9 301 165 -1.6 0 -1.4 -1.7 02/26/2006 12:00:00 13.5 1.7 16.8 8.4 13.4 1.7 16.8 8.4 11.5 1.9 16.1 6.5 307 8 309 165 -1.6 0 -1.4 -1.7 02/26/2006 12:10:00 10.9 1.6 14.5 6.5 10.8 1.6 14.9 6.1 9 1.6 12.6 4.9 303 8 308 165 -1.5 0 -1.4 -1.7 02/26/2006 12:20:00 12.8 1.4 17.2 9.1 12.8 1.5 17.2 8.8 9.9 1.5 14.1 6.5 299 7 298 165 -1.4 0 -1.4 -1.4 02/26/2006 12:30:00 12.4 1.5 15.6 8.4 12.3 1.5 15.6 8 10.2 1.5 15.3 6.5 300 9 293 165 -1.4 0 -1.2 -1.4 02/26/2006 12:40:00 9.2 2 14.5 4.9 9.2 1.9 14.1 4.6 8 2 13.3 3.8 304 10 312 165 -1.2 0 -1 -1.4 02/26/2006 12:50:00 8.3 1.8 13 5.3 8.2 1.8 13.3 5.3 7 1.5 11.5 4.2 303 9 292 165 -1 0.1 -0.8 -1.2 02/26/2006 13:00:00 9.2 1.2 12.2 5.7 9.2 1.2 11.8 6.1 8.3 1.3 11.8 4.9 295 13 302 165 -0.9 0 -0.5 -1 02/26/2006 13:10:00 11.4 1.5 16.4 7.2 11.5 1.5 16.4 7.2 9.9 2 14.9 5.3 296 10 287 165 -0.9 0.1 -0.5 -1 02/26/2006 13:20:00 11 1.3 14.5 6.8 11 1.3 14.5 6.5 9.1 1.7 14.5 4.2 294 7 287 165 -0.9 0 -0.8 -1 02/26/2006 13:30:00 11.1 1.3 15.6 8 11 1.3 15.6 7.6 9.1 1.5 14.5 6.1 300 8 315 165 -0.8 0 -0.5 -1 02/26/2006 13:40:00 9.8 1.3 13 6.1 9.8 1.3 13.3 6.1 8.1 1.1 11.8 5.3 304 9 302 165 -0.7 0 -0.5 -1 02/26/2006 13:50:00 9.9 1.1 12.6 6.1 9.9 1.1 12.6 6.1 7.9 1.2 11.1 4.9 297 9 307 165 -0.6 0 -0.5 -0.8 02/26/2006 14:00:00 10.8 1.2 14.1 7.2 10.7 1.3 13.7 7.2 9.3 1.7 13.7 6.1 300 11 297 165 -0.5 0 -0.3 -0.5 02/26/2006 14:10:00 12.6 1.4 16.4 8.8 12.5 1.4 16.4 8.8 10.5 2 16.1 6.8 306 8 310 165 -0.3 0 -0.3 -0.5 02/26/2006 14:20:00 12.7 1.3 17.6 9.5 12.6 1.3 17.6 9.1 10.5 1.5 14.1 7.2 308 6 305 165 -0.3 0 -0.1 -0.5 02/26/2006 14:30:00 10.8 0.9 13 8.4 10.7 0.9 13 8.4 9.5 1.4 12.2 5.7 309 5 309 165 -0.2 0 -0.1 -0.3 02/26/2006 14:40:00 8.5 1.2 11.8 5.3 8.4 1.2 11.5 5.3 7.3 1.3 10.3 4.6 307 8 302 165 -0.1 0 0.2 -0.3 02/26/2006 14:50:00 10.7 1.3 13.3 6.8 10.7 1.3 13.3 6.8 8.4 1.3 11.8 5.3 298 7 297 165 0 0 0.2 -0.1 02/26/2006 15:00:00 10.4 1.7 14.5 6.8 10.3 1.7 14.1 6.8 8.7 1.5 13.3 5.3 301 9 299 165 0 0 0.2 -0.1 02/26/2006 15:10:00 8.9 1.1 11.5 5.3 8.9 1.1 11.8 6.1 7.8 1.2 10.7 4.6 307 8 305 165 0.1 0 0.2 -0.1 02/26/2006 15:20:00 7.7 1.5 11.1 4.6 7.8 1.5 11.1 4.9 6.4 1.5 10.3 3.8 297 9 292 165 0.1 0 0.2 -0.1 02/26/2006 15:30:00 7.1 0.9 9.5 4.9 7.1 0.9 9.9 4.6 6.2 1.1 8.8 3.8 302 10 304 165 0.2 0 0.2 -0.1 02/26/2006 15:40:00 7.5 1 10.7 4.9 7.4 1 10.7 4.6 6.3 1.2 10.3 4.2 307 8 307 165 0.2 0 0.4 0.2 02/26/2006 15:50:00 5.6 0.9 8.4 3.8 5.7 0.8 8.4 4.2 4.9 0.8 6.8 3 309 8 311 165 0.5 0.1 0.7 0.2 02/26/2006 16:00:00 4.6 1.1 6.8 1.5 4.6 1 6.5 1.9 4.2 1.1 6.5 1.5 301 17 320 165 0.5 0 0.7 0.4 02/26/2006 16:10:00 3.7 1.4 6.8 0.7 3.8 1.3 7.2 1.1 3.4 1.3 6.5 0.7 301 19 313 165 0.6 0 0.9 0.2 02/26/2006 16:20:00 5.8 0.8 8.4 3.8 5.8 0.8 8.8 3.4 5.1 0.9 7.6 3 303 13 287 165 0.2 0.1 0.7 -0.1 02/26/2006 16:30:00 6.7 1.3 10.3 4.2 6.7 1.4 10.7 4.2 5.7 1.3 9.5 3.4 300 11 278 165 0.1 0 0.2 -0.1 02/26/2006 16:40:00 7.1 0.9 9.1 4.9 7.1 0.9 9.1 4.9 5.8 1 9.1 3.4 299 9 295 165 0 0 0.2 -0.1 02/26/2006 16:50:00 7 1 9.9 4.9 7 0.9 10.3 4.9 6.2 1 9.5 3.4 303 11 281 165 0.1 0 0.2 -0.1 02/26/2006 17:00:00 7.7 1.3 11.1 3.8 7.7 1.3 11.1 3.8 6.3 1.2 9.5 3.4 302 12 295 165 0.1 0 0.2 -0.1 02/26/2006 17:10:00 6.8 1.5 10.7 3.4 6.8 1.5 10.7 3.4 5.7 1.5 10.7 2.6 294 12 277 165 0.2 0 0.2 0.2 02/26/2006 17:20:00 7.3 1.1 9.5 4.2 7.4 1.1 9.9 4.2 6.4 1.2 9.5 3.8 287 8 289 165 0.2 0 0.2 0.2 02/26/2006 17:30:00 6.3 1.3 9.5 3.8 6.6 1.3 10.3 3.8 6.1 1.2 9.9 3 282 11 296 165 0.2 0 0.2 -0.1 02/26/2006 17:40:00 5 1.2 8 2.3 5.9 1.1 8.4 3.4 5.6 1 8.4 3.4 267 10 272 165 0 0 0.2 -0.1 02/26/2006 17:50:00 5.5 1.4 8.8 2.3 5.8 1.2 9.1 2.6 5.3 1.3 8.8 2.6 280 9 284 165 -0.1 0 0.2 -0.3 02/26/2006 18:00:00 8 1.7 11.5 3.4 8.1 1.7 11.5 4.6 7.4 1.8 11.1 3.4 283 7 290 165 0.1 0 0.2 -0.3 02/26/2006 18:10:00 6.1 1.2 8.8 3 6.4 1 9.1 3.4 5.9 1.2 8.8 2.6 278 11 265 165 0.1 0 0.2 -0.1 02/26/2006 18:20:00 4.1 1.8 7.6 0.4 4.5 1.7 7.6 1.5 3.8 1.7 7.2 1.1 272 15 288 165 0 0 0.2 -0.1 02/26/2006 18:30:00 4.7 1.4 8 1.1 5.1 1.2 8 1.5 4.4 1.2 8.4 1.1 279 13 283 165 0 0 0.2 -0.3 02/26/2006 18:40:00 4.1 1.3 7.2 1.5 4.7 1.1 7.6 2.6 4.6 0.9 6.8 2.6 268 10 281 165 0.1 0 0.2 -0.1 02/26/2006 18:50:00 6.3 2 11.5 3 7.2 1.7 11.5 4.2 6.7 1.7 11.5 3.8 271 9 282 165 0.1 0.1 0.4 -0.1 02/26/2006 19:00:00 10.8 0.9 13 8.8 10.8 0.9 13 8.4 8.4 1.2 11.8 5.7 295 7 298 165 0.5 0 0.7 0.2 02/26/2006 19:10:00 8.7 2.2 12.2 2.3 8.7 2.1 12.6 1.9 7.2 2 11.8 2.3 289 23 302 165 0.4 0.1 0.7 0.2 02/26/2006 19:20:00 8.3 2.1 12.6 2.3 8.3 2 12.6 1.1 6.7 2.3 11.1 1.1 291 12 287 165 0.2 0 0.4 -0.1 02/26/2006 19:30:00 6.8 1.8 11.5 2.3 6.9 1.7 11.5 2.6 5.4 1.8 11.1 1.5 298 15 310 165 0.2 0 0.4 0.2 02/26/2006 19:40:00 3.8 2.1 9.9 0.4 4.1 2.1 9.9 0.4 3 1.7 8 0.4 285 30 301 165 0.2 0 0.2 0.2 02/26/2006 19:50:00 0.6 0.3 1.5 0.4 0.6 0.3 1.5 0.4 0.7 0.4 1.9 0.4 181 51 218 165 0.1 0 0.2 -0.1 02/26/2006 20:00:00 0.7 0.4 1.9 0.4 0.7 0.4 2.3 0.4 0.7 0.4 1.9 0.4 203 22 247 165 0.1 0 0.2 -0.1 02/26/2006 20:10:00 3.6 1.2 6.1 0.7 4 1.2 6.5 1.5 3.6 1.2 6.1 0.7 277 11 280 165 0.2 0 0.4 -0.1 02/26/2006 20:20:00 2 1 4.9 0.4 2.5 1.1 4.9 0.4 2.4 1 5.3 0.4 238 24 284 165 0.2 0 0.2 0.2 02/26/2006 20:30:00 0.8 0.5 2.6 0.4 1 0.6 3 0.4 1.2 0.5 3 0.4 219 26 242 165 0.2 0 0.4 -0.1 02/26/2006 20:40:00 1.1 0.5 2.6 0.4 1.3 0.5 2.6 0.4 1.5 0.5 3 0.4 213 22 201 165 0.4 0 0.7 -0.1 02/26/2006 20:50:00 2.1 0.5 3.4 0.7 2.2 0.5 3.4 0.7 2.2 0.4 3 1.1 180 9 173 165 0.3 0 0.4 0.2 02/26/2006 21:00:00 2.9 0.6 4.6 1.5 3 0.6 4.9 1.5 3.1 0.7 4.9 1.9 193 19 194 165 0.4 0 0.7 0.2 02/26/2006 21:10:00 3.3 0.4 4.2 2.3 3.4 0.4 4.6 2.6 3.6 0.4 4.2 2.3 207 7 215 165 0.2 0 0.4 0.2 02/26/2006 21:20:00 2.7 0.7 4.2 0.4 2.9 0.6 4.2 1.1 2.8 0.7 4.6 0.7 227 16 220 165 0.3 0 0.7 0.2 02/26/2006 21:30:00 2.1 0.8 3.8 0.4 2.5 0.7 3.8 0.4 2.4 0.7 4.2 0.4 236 17 247 165 0.4 0 0.7 0.2 02/26/2006 21:40:00 0.5 0.3 1.9 0.4 0.7 0.4 2.3 0.4 1.3 0.5 2.3 0.4 131 23 176 165 0.2 0 0.4 -0.1 02/26/2006 21:50:00 1.7 0.8 3.4 0.4 1.7 0.8 4.2 0.4 2.1 0.6 4.9 0.4 202 11 211 165 0.2 0 0.4 -0.1 02/26/2006 22:00:00 3.3 0.5 4.6 1.1 3.6 0.5 4.9 1.5 3.5 0.5 5.3 1.5 244 9 265 165 0.2 0 0.4 -0.1 02/26/2006 22:10:00 3.7 0.7 4.9 1.5 4.1 0.5 4.9 2.3 4 0.5 4.9 2.6 268 13 279 165 0.1 0 0.2 -0.1 02/26/2006 22:20:00 2.3 1 4.6 0.4 2.7 1 4.9 0.7 2.8 0.9 5.3 1.5 261 20 281 165 0.2 0 0.4 -0.1 02/26/2006 22:30:00 2.9 0.4 3.8 1.9 3.1 0.3 3.8 1.9 3.2 0.4 4.2 2.3 212 7 194 165 -0.1 0.1 0.2 -0.3 02/26/2006 22:40:00 2.4 0.6 3.8 0.7 2.5 0.6 3.8 0.7 2.7 0.6 3.8 1.1 213 8 227 165 -0.2 0 -0.1 -0.3 02/26/2006 22:50:00 2.2 0.5 3.8 1.1 2.4 0.5 3.8 1.1 2.6 0.5 4.2 1.5 211 9 208 165 -0.2 0 -0.1 -0.3 02/26/2006 23:00:00 2.6 0.9 4.6 0.7 2.6 0.8 4.6 1.1 2.9 0.6 4.6 1.9 211 10 200 165 -0.3 0 -0.1 -0.3 02/26/2006 23:10:00 3.1 0.6 4.6 1.5 3.2 0.6 4.2 1.5 3.4 0.6 4.6 1.9 192 9 189 165 -0.3 0 -0.1 -0.5 02/26/2006 23:20:00 2 0.9 3.8 0.4 2.2 0.9 4.2 0.4 2.5 0.9 3.8 0.4 212 19 218 165 -0.3 0 -0.1 -0.5 02/26/2006 23:30:00 2.5 1 4.6 0.4 2.9 0.9 4.9 0.4 2.6 0.8 4.6 0.7 278 17 274 165 -0.2 0 -0.1 -0.5 02/26/2006 23:40:00 3.7 0.6 5.3 2.3 3.9 0.6 5.3 2.3 3.4 0.7 4.9 1.5 284 7 282 165 -0.3 0 -0.1 -0.5 02/26/2006 23:50:00 2.8 0.8 4.9 0.7 3.4 0.7 4.9 1.9 3.3 0.6 4.9 1.9 270 12 277 165 -0.3 0 -0.1 -0.5 02/27/2006 00:00:00 2.3 0.6 3.8 0.7 3.2 0.5 4.6 1.9 3 0.5 4.2 1.9 264 7 251 165 -0.3 0 -0.1 -0.5 02/27/2006 00:10:00 1.5 0.8 3.4 0.4 1.8 0.8 3.4 0.4 1.9 0.5 3.4 0.7 240 13 244 165 -0.3 0 -0.1 -0.5 02/27/2006 00:20:00 2.6 0.7 4.2 0.4 2.7 0.7 4.2 0.4 2.7 0.6 4.2 1.1 214 8 218 165 -0.3 0 -0.1 -0.5 02/27/2006 00:30:00 4.1 0.9 5.3 1.5 4.3 0.9 5.7 1.5 4.1 1.1 5.7 1.5 214 6 218 165 -0.6 0 -0.3 -0.8 02/27/2006 00:40:00 5.1 0.6 6.5 3.4 5.3 0.6 6.8 3.8 5.1 0.6 6.5 3 219 5 212 165 -0.7 0 -0.5 -0.8 02/27/2006 00:50:00 3.8 0.6 5.3 2.3 3.9 0.6 5.7 2.3 3.8 0.6 5.7 2.3 226 9 217 165 -0.8 0 -0.5 -0.8 02/27/2006 01:00:00 3.6 0.7 4.9 1.9 3.7 0.6 4.9 1.9 3.4 0.6 5.3 1.9 223 8 224 165 -0.6 0 -0.5 -0.8 02/27/2006 01:10:00 3.7 0.5 4.9 1.9 3.8 0.5 5.3 2.6 3.6 0.6 4.9 2.3 216 9 220 165 -0.6 0 -0.5 -0.8 02/27/2006 01:20:00 2 1 3.8 0.4 2.1 1 4.2 0.4 2.2 0.9 3.8 0.7 201 12 207 165 -0.8 0.1 -0.5 -0.8 02/27/2006 01:30:00 2 0.7 3.8 0.4 2.1 0.7 3.8 0.7 1.9 0.6 3.4 0.7 215 9 214 165 -0.9 0 -0.8 -0.8 02/27/2006 01:40:00 2.1 0.5 3.4 0.7 2.3 0.6 3.4 1.1 2.3 0.5 3.8 1.1 224 6 217 165 -0.7 0 -0.5 -0.8 02/27/2006 01:50:00 1.4 0.6 3 0.4 1.6 0.5 3 0.4 1.8 0.5 3 0.7 239 8 241 165 -0.5 0.1 -0.3 -0.8 02/27/2006 02:00:00 0.8 0.6 2.6 0.4 1.1 0.6 2.6 0.4 1.1 0.5 2.6 0.4 233 11 224 165 -0.5 0 -0.3 -0.8 02/27/2006 02:10:00 1.9 0.9 4.6 0.4 2.1 0.8 4.6 0.4 2.1 0.7 4.2 0.7 227 13 241 165 -0.5 0 -0.5 -0.8 02/27/2006 02:20:00 1.9 1 4.9 0.4 2.3 1 4.9 0.4 2.5 0.9 4.6 1.1 238 22 272 165 -0.7 0 -0.5 -0.8 02/27/2006 02:30:00 2.4 0.6 4.2 0.7 3 0.6 4.6 1.5 3 0.5 4.6 1.9 250 12 252 165 -0.5 0 -0.3 -0.5 02/27/2006 02:40:00 2.6 0.5 3.8 1.1 2.9 0.5 4.2 1.5 2.7 0.4 4.2 1.9 237 7 230 165 -0.4 0 -0.3 -0.5 02/27/2006 02:50:00 1.2 0.5 2.3 0.4 1.4 0.5 2.6 0.4 1.7 0.3 2.6 1.1 212 13 217 165 -0.4 0 -0.3 -0.8 02/27/2006 03:00:00 2 0.8 4.2 0.4 2.1 0.7 3.8 0.4 2.3 0.6 4.2 1.1 187 13 195 165 -0.6 0 -0.5 -0.8 02/27/2006 03:10:00 2.5 0.5 3.8 0.7 2.5 0.5 3.4 0.7 2.6 0.5 3.8 1.5 193 6 189 165 -0.8 0 -0.5 -0.8 02/27/2006 03:20:00 2.2 0.8 3.4 0.4 2.2 0.7 3.4 0.4 2.5 0.7 3.8 0.4 193 19 198 165 -0.6 0 -0.5 -0.8 02/27/2006 03:30:00 1.6 0.4 2.3 0.4 1.6 0.4 2.6 0.4 1.9 0.3 2.6 1.1 184 8 177 165 -0.6 0 -0.5 -0.8 02/27/2006 03:40:00 1.3 0.6 3 0.4 1.3 0.6 2.6 0.4 1.5 0.5 3 0.4 192 13 205 165 -0.6 0 -0.5 -0.8 02/27/2006 03:50:00 0.8 0.6 2.6 0.4 0.9 0.6 2.6 0.4 1 0.5 2.3 0.4 211 22 238 165 -0.5 0.1 -0.3 -0.8 02/27/2006 04:00:00 1.1 0.6 2.3 0.4 1.2 0.6 2.6 0.4 1.3 0.5 2.3 0.4 206 18 223 165 -0.4 0 -0.3 -0.5 02/27/2006 04:10:00 0.9 0.5 1.9 0.4 0.9 0.5 1.9 0.4 1.6 0.4 2.6 0.4 140 11 130 165 -0.7 0.1 -0.5 -0.8 02/27/2006 04:20:00 0.6 0.6 3 0.4 0.7 0.7 3 0.4 0.7 0.6 3 0.4 184 58 284 165 -0.8 0 -0.5 -0.8 02/27/2006 04:30:00 0.6 0.4 1.9 0.4 0.7 0.5 2.3 0.4 0.8 0.5 2.3 0.4 251 12 275 165 -0.5 0.1 -0.3 -1 02/27/2006 04:40:00 1.8 1.1 4.2 0.4 2.2 1.1 4.2 0.4 1.9 1 3.8 0.4 270 15 287 165 -0.2 0.1 0.2 -0.5 02/27/2006 04:50:00 4.7 1.7 10.7 1.1 4.9 1.5 10.7 2.3 4.4 1.5 10.7 1.9 284 11 279 165 0 0 0.2 -0.3 02/27/2006 05:00:00 10.4 2.2 14.9 5.7 10.4 2.1 14.5 6.5 9.5 2.5 14.1 4.6 305 15 319 165 -0.4 0.3 0.2 -1 02/27/2006 05:10:00 10.4 1.3 14.1 6.8 10.3 1.3 14.1 6.5 9.4 1.2 13 6.5 313 9 304 165 -1.3 0.1 -1 -1.7 02/27/2006 05:20:00 7.7 1.6 12.6 3.8 7.7 1.5 11.8 4.2 6.5 1.5 10.3 3 297 12 306 165 -1.6 0 -1.4 -1.9 02/27/2006 05:30:00 6.4 1 9.1 3.8 6.4 1 8.8 4.2 5.3 1 8.4 3 293 9 294 165 -1.6 0 -1.4 -1.7 02/27/2006 05:40:00 4.8 0.9 6.8 2.3 4.9 0.8 7.2 3 4.3 0.9 6.5 2.3 286 10 290 165 -1.7 0 -1.4 -1.9 02/27/2006 05:50:00 4.1 0.7 6.1 2.3 4.2 0.7 6.5 2.6 3.7 0.8 6.1 1.9 292 12 297 165 -1.7 0 -1.4 -1.9 02/27/2006 06:00:00 6.7 2.9 12.2 1.5 6.7 2.9 12.2 1.5 5.8 2.5 11.8 1.9 307 13 305 165 -1.6 0 -1.4 -1.7 02/27/2006 06:10:00 11.8 1.5 15.6 8.4 11.7 1.5 15.6 8.4 10.6 1.7 15.6 6.5 310 8 306 165 -1.9 0.1 -1.7 -2.1 02/27/2006 06:20:00 12 1.4 16.1 8.8 12 1.4 16.1 8.8 11.9 1.5 16.8 7.6 321 8 311 165 -2.1 0 -1.9 -2.4 02/27/2006 06:30:00 11.9 1.2 15.3 8.8 11.8 1.1 14.9 8.4 11.3 1.5 14.5 6.5 318 10 307 165 -2.2 0 -2.1 -2.4 02/27/2006 06:40:00 14.5 1.2 17.9 11.1 14.4 1.2 17.6 11.5 13.7 1.9 17.6 8.4 314 6 313 165 -2.4 0 -2.1 -2.6 02/27/2006 06:50:00 18.3 1.1 21 14.9 18.2 1.1 21 14.5 16.9 1.5 22.6 12.2 311 4 308 165 -2.5 0 -2.4 -2.6 02/27/2006 07:00:00 18 1.3 21.4 14.1 18 1.3 21.4 14.1 14.4 1.7 21 10.7 305 5 310 165 -2.7 0 -2.6 -2.8 02/27/2006 07:10:00 16.1 1.6 19.9 11.1 15.9 1.6 20.2 10.7 14.5 1.5 20.2 9.9 312 7 310 165 -3 0.1 -2.8 -3.3 02/27/2006 07:20:00 16 1.2 18.3 11.8 15.9 1.2 17.9 11.5 13.8 1.4 17.2 9.1 310 5 309 165 -3.2 0 -3 -3.3 02/27/2006 07:30:00 15.6 1.1 18.7 13 15.5 1.1 18.7 13 13.8 1.5 17.6 9.5 310 5 301 165 -3.4 0 -3.3 -3.5 02/27/2006 07:40:00 16.8 0.9 19.1 13.7 16.7 0.9 19.1 13.3 14.9 1.2 18.3 11.8 310 4 309 165 -3.6 0 -3.5 -3.7 02/27/2006 07:50:00 17.5 1.1 20.6 14.5 17.4 1.1 20.6 14.5 16.3 1.7 20.2 11.1 312 6 317 165 -3.6 0 -3.5 -3.7 02/27/2006 08:00:00 18.8 1.3 22.6 15.3 18.7 1.4 21.8 15.3 17.2 1.6 21 11.8 310 6 303 165 -3.7 0 -3.5 -3.9 02/27/2006 08:10:00 18.9 1.3 21.8 14.9 18.8 1.3 21.8 14.5 17.2 1.9 21 11.5 311 6 305 165 -3.8 0 -3.7 -3.9 02/27/2006 08:20:00 19.2 1.2 23.7 15.6 19.1 1.3 23.3 15.6 18.5 1.7 22.6 13.3 314 5 314 165 -3.9 0 -3.7 -3.9 02/27/2006 08:30:00 20.6 1.2 23.3 16.4 20.5 1.3 23.3 16.4 19.7 1.4 22.6 14.9 311 4 307 165 -4 0.1 -3.9 -4.2 02/27/2006 08:40:00 22.2 1.7 25.6 17.2 22.1 1.8 26 17.2 21.9 2.1 26 16.8 314 5 311 165 -4.3 0 -3.9 -4.4 02/27/2006 08:50:00 24 1.6 27.1 19.5 23.9 1.6 27.1 19.1 23.2 1.6 27.1 17.9 310 4 305 165 -4.5 0.1 -4.4 -4.6 02/27/2006 09:00:00 21.8 1.9 27.1 16.8 21.8 1.9 27.1 16.8 21 2 27.5 15.6 312 6 305 165 -4.7 0 -4.6 -4.8 02/27/2006 09:10:00 20.9 1.5 24.4 16.4 20.8 1.6 24.4 16.1 20.5 1.7 24.4 14.9 315 5 318 165 -4.7 0 -4.4 -4.8 02/27/2006 09:20:00 22.9 1.3 27.1 19.5 22.9 1.3 26.8 19.9 21.8 1.6 26.3 16.8 310 4 310 165 -4.7 0.1 -4.4 -4.8 02/27/2006 09:30:00 23.2 1.5 26.3 17.9 23.1 1.6 26 18.3 22.1 1.5 26 17.6 310 5 310 165 -4.7 0 -4.6 -4.8 02/27/2006 09:40:00 21.8 1.8 27.5 17.6 21.7 1.8 27.1 17.2 21.4 2 27.1 15.6 314 6 300 165 -4.8 0 -4.6 -5 02/27/2006 09:50:00 21.8 1.8 26 16.4 21.7 1.9 26 16.1 21.2 2.3 26 13.3 313 6 309 165 -5.2 0.1 -5 -5.5 02/27/2006 10:00:00 21.3 1.6 25.6 17.2 21.2 1.6 25.2 17.2 20.4 1.7 25.2 15.3 312 5 305 165 -5.5 0 -5.5 -5.7 02/27/2006 10:10:00 20.8 1.8 25.2 16.4 20.8 1.8 25.2 16.4 20 2.1 25.6 14.9 312 5 310 165 -5.5 0 -5.5 -5.7 02/27/2006 10:20:00 20 1.4 24 16.1 20 1.4 24.4 16.1 19.4 1.6 23.7 15.3 313 6 316 165 -5.6 0 -5.5 -5.7 02/27/2006 10:30:00 20.3 1.5 23.7 16.1 20.3 1.4 23.7 15.6 19.3 1.5 23.7 14.9 311 5 317 165 -5.7 0.1 -5.5 -5.7 02/27/2006 10:40:00 19 1.1 21.4 16.1 18.9 1.1 21.4 16.1 18.4 1.2 21.4 14.9 313 4 314 165 -5.6 0 -5.5 -5.7 02/27/2006 10:50:00 18.6 1.5 23.7 14.5 18.5 1.6 23.7 14.1 18.2 1.6 22.6 14.1 318 7 333 165 -5.2 0.1 -4.8 -5.7 02/27/2006 11:00:00 18.8 1.2 22.9 16.4 18.8 1.2 22.9 15.6 18.1 1.3 21.4 14.5 313 6 307 165 -5.3 0 -5 -5.5 02/27/2006 11:10:00 19.9 1.7 23.7 15.6 19.9 1.7 23.7 15.6 19.4 1.7 23.3 14.1 313 5 312 165 -5.6 0 -5.5 -5.7 02/27/2006 11:20:00 19.2 1.4 22.6 15.6 19.1 1.4 22.6 15.3 18.4 1.5 22.1 14.9 311 5 309 165 -5.7 0 -5.5 -5.7 02/27/2006 11:30:00 19.6 1.5 23.7 15.3 19.5 1.5 24 15.6 18.7 1.7 23.7 14.5 314 7 311 165 -5.6 0 -5.5 -5.7 02/27/2006 11:40:00 20.3 1.6 24.4 15.6 20.2 1.7 24 16.1 19.9 2.1 24.4 14.1 316 6 312 165 -5.6 0 -5.5 -5.7 02/27/2006 11:50:00 20.6 1.7 23.7 16.1 20.5 1.7 23.7 16.1 20.1 1.7 24 15.6 316 8 309 165 -5.9 0 -5.7 -6.1 02/27/2006 12:00:00 19.5 1.4 22.9 16.4 19.4 1.5 22.9 16.4 18.9 1.7 22.6 14.1 315 5 314 165 -6.1 0 -5.9 -6.1 02/27/2006 12:10:00 19 1.7 24.4 14.1 18.9 1.7 24.4 13.3 18.6 1.7 22.9 13.7 316 5 306 165 -6 0 -5.7 -6.1 02/27/2006 12:20:00 17.1 2 24 12.2 17 2 23.7 12.6 16.5 2 22.6 10.3 317 9 313 165 -6 0 -5.7 -6.1 02/27/2006 12:30:00 17 2.1 22.1 11.8 16.9 2.1 22.1 11.5 16.1 2.1 21.4 10.7 313 9 309 165 -6.2 0.1 -6.1 -6.6 02/27/2006 12:40:00 18.2 1.7 23.7 13.7 18.2 1.7 23.3 13.7 17.6 1.9 23.3 11.8 315 8 307 165 -6.5 0 -6.4 -6.6 02/27/2006 12:50:00 19 1.7 23.3 14.9 18.9 1.7 22.9 15.3 18.3 1.7 23.3 13.3 314 7 319 165 -6.7 0 -6.4 -6.8 02/27/2006 13:00:00 18 2 23.7 13 17.9 2 23.3 13 17.4 2.3 22.9 12.2 317 8 314 165 -6.8 0 -6.6 -6.8 02/27/2006 13:10:00 17.8 1.6 24.4 13 17.7 1.7 25.2 12.6 17.2 1.7 21.8 12.2 317 9 308 165 -6.7 0 -6.6 -6.8 02/27/2006 13:20:00 19.7 2.5 25.6 11.1 19.6 2.4 25.6 10.7 19 2.4 24.4 11.8 315 7 307 165 -6.7 0 -6.6 -6.8 02/27/2006 13:30:00 18 2 22.9 12.6 17.9 1.9 22.9 12.6 17 2.1 24.4 11.1 317 9 298 165 -6.7 0 -6.6 -6.8 02/27/2006 13:40:00 17.9 2.1 22.9 11.5 17.8 2.1 23.3 11.1 17.1 2.3 22.9 11.5 316 9 306 165 -6.7 0.1 -6.6 -6.8 02/27/2006 13:50:00 18.5 2.2 24.8 14.1 18.5 2.2 24.8 14.5 18.1 2.2 24.8 12.6 316 9 308 165 -6.9 0 -6.8 -7 02/27/2006 14:00:00 20.1 1.7 25.2 16.1 20.1 1.7 25.2 16.1 19.4 1.7 24 14.1 313 6 309 165 -7.1 0 -6.8 -7.2 02/27/2006 14:10:00 20.4 1.5 24.8 17.2 20.3 1.5 24.4 16.8 19.8 1.7 24.4 14.9 314 6 315 165 -7.1 0 -6.8 -7.2 02/27/2006 14:20:00 19.6 1.8 24 15.3 19.5 1.8 24 14.9 18.8 1.8 22.6 13.3 315 5 315 165 -7.1 0 -6.8 -7.2 02/27/2006 14:30:00 19.9 2 24.8 13.3 19.8 2 24.8 13.3 19.1 2.2 24 13.3 312 7 305 165 -7.1 0 -6.8 -7.4 02/27/2006 14:40:00 19.6 1.8 23.3 13 19.5 1.8 23.3 13.3 18.7 1.9 23.3 13 312 5 309 165 -7.3 0 -6.8 -7.4 02/27/2006 14:50:00 19 1.7 23.3 14.9 18.9 1.6 22.9 14.5 17.8 1.7 21.8 11.8 313 6 317 165 -7.4 0 -7.2 -7.4 02/27/2006 15:00:00 19.3 1.8 23.3 13.7 19.1 1.8 22.9 13.7 18.3 1.9 23.7 13 313 6 312 165 -7.4 0 -7.2 -7.6 02/27/2006 15:10:00 18.1 1.8 23.3 13.3 18 1.8 23.3 12.6 17 1.8 21 11.5 313 7 311 165 -7.2 0 -7 -7.4 02/27/2006 15:20:00 16.7 1.9 21.8 11.5 16.6 1.8 21 11.5 15.5 1.9 21 10.3 314 9 316 165 -6.9 0.1 -6.6 -7.2 02/27/2006 15:30:00 15 1.9 21.8 9.9 14.9 1.9 21.4 9.9 13.7 2.1 21.4 8 314 11 328 165 -6.7 0 -6.6 -6.8 02/27/2006 15:40:00 15 1.7 19.1 9.1 14.9 1.7 18.7 8.8 13.6 1.9 18.3 9.1 319 14 297 165 -6.6 0 -6.6 -6.8 02/27/2006 15:50:00 14.1 2 21.4 9.1 13.9 1.8 19.9 8.8 13.3 2 20.2 8.8 328 15 344 165 -6.5 0 -6.4 -6.8 02/27/2006 16:00:00 15.2 2 22.6 8 14.9 1.9 18.7 8.4 14.7 1.9 19.9 9.5 329 15 351 165 -6.6 0 -6.6 -6.8 02/27/2006 16:10:00 15.6 1.8 24 10.7 15.5 1.8 23.7 10.7 14.3 1.7 18.7 8.8 319 12 314 165 -6.7 0 -6.6 -6.8 02/27/2006 16:20:00 15.6 2.1 22.1 10.3 15.3 2 22.1 10.7 15 2.1 21.4 10.7 326 14 340 165 -6.7 0.1 -6.6 -6.8 02/27/2006 16:30:00 16.9 2.3 23.7 10.7 16.5 2.4 23.3 9.9 15.9 2.3 22.1 11.1 324 17 300 165 -6.9 0 -6.8 -7 02/27/2006 16:40:00 17 2.5 23.3 11.1 16.8 2.6 23.7 10.7 16.4 2.4 22.9 10.7 330 13 313 165 -6.9 0 -6.8 -6.8 02/27/2006 16:50:00 18.2 2.4 26 11.1 17.6 2.6 25.6 9.9 17.6 2.6 24.8 11.1 338 15 358 165 -6.8 0 -6.6 -7 02/27/2006 17:00:00 17.8 2 23.7 11.8 17.2 2.1 22.6 11.5 17.4 2.1 23.7 11.5 334 13 336 165 -6.9 0 -6.8 -7 02/27/2006 17:10:00 18.1 3.2 30.2 11.1 17.6 3.2 30.6 11.1 17.6 3.1 28.3 9.5 337 14 345 165 -7.1 0 -6.8 -7.2 02/27/2006 17:20:00 17.2 2.7 24.4 10.3 16.7 2.8 24.8 9.1 16.3 2.9 22.9 9.5 334 15 359 165 -7.2 0 -7 -7.2 02/27/2006 17:30:00 17.4 2.7 24.8 11.5 16.5 2.4 22.6 11.8 16.6 2.7 24.8 10.3 336 14 353 165 -7.2 0 -7 -7.4 02/27/2006 17:40:00 16.3 2.3 22.9 9.9 15.8 2.5 22.6 9.5 15.8 2.4 22.6 9.9 335 15 336 165 -7.2 0 -7 -7.2 02/27/2006 17:50:00 15.3 2.5 23.3 9.9 15 2.6 22.9 8.4 14.6 2.8 23.3 7.2 336 15 326 165 -7.2 0 -7 -7.2 02/27/2006 18:00:00 14.8 2.5 21.8 8.4 14.7 2.5 21.4 8.8 14 2.6 20.6 6.8 335 12 329 165 -7.2 0 -7 -7.2 02/27/2006 18:10:00 15.7 2.2 21.4 9.9 15.3 2.2 21.8 9.9 15.1 2.1 21 9.9 338 12 358 165 -7.3 0 -7.2 -7.4 02/27/2006 18:20:00 17.2 2.3 24 10.7 17.2 2.4 24.4 11.1 16.6 2.3 23.3 10.3 331 11 333 165 -7.3 0 -7.2 -7.4 02/27/2006 18:30:00 18.6 2.8 24.8 11.8 18.2 2.7 24.8 10.7 18.4 3.1 25.6 12.2 335 11 355 165 -7.3 0 -7.2 -7.4 02/27/2006 18:40:00 18.6 2.5 27.1 13.3 18.2 2.8 27.5 11.1 18.5 2.6 26.8 11.5 336 13 334 165 -7.3 0 -7.2 -7.4 02/27/2006 18:50:00 19.4 2.7 27.5 13.7 19.2 2.7 27.5 13.7 18.9 3.1 27.1 13.3 337 12 335 165 -7.4 0 -7.2 -7.4 02/27/2006 19:00:00 19.2 2.9 27.9 12.6 18.7 3.5 27.1 10.3 18.8 2.9 26 12.6 338 12 353 165 -7.4 0 -7.2 -7.4 02/27/2006 19:10:00 19.3 2.4 25.6 12.2 19.2 2.4 25.2 11.5 18.2 2.5 26 11.1 318 14 328 165 -7.5 0 -7.2 -7.6 02/27/2006 19:20:00 22.2 2.7 31.3 13 22.2 2.7 31.3 12.6 21.7 2.7 29.1 15.3 315 11 306 165 -7.5 0 -7.4 -7.6 02/27/2006 19:30:00 22 2.9 32.9 13.7 22 2.9 32.1 12.6 21 3.3 29.4 13 316 11 295 165 -7.6 0 -7.4 -7.6 02/27/2006 19:40:00 21.9 3.1 32.4 13 21.9 2.9 32.1 13.3 21.4 3.2 29.1 12.2 319 10 310 165 -7.6 0 -7.4 -7.6 02/27/2006 19:50:00 20.1 2.6 28.3 13 20 2.6 27.9 12.6 19 2.8 27.1 11.8 321 13 329 165 -7.6 0 -7.4 -7.9 02/27/2006 20:00:00 21.3 2.4 30.9 14.9 21 2.5 30.6 14.5 20.9 2.5 30.2 15.3 333 11 332 165 -7.6 0 -7.4 -7.6 02/27/2006 20:10:00 21.4 2.7 27.9 15.6 21.3 2.7 29.1 13.3 21.2 2.6 28.3 14.1 336 10 350 165 -7.5 0 -7.4 -7.6 02/27/2006 20:20:00 24.9 3.1 34 17.2 24.6 3.3 34 16.4 24.9 3.5 34.8 15.6 337 10 340 165 -7.4 0 -7.2 -7.6 02/27/2006 20:30:00 25 3.3 34 15.3 24.9 3.5 33.2 14.9 24.8 3.5 32.9 14.5 336 8 336 165 -7.2 0 -7 -7.4 02/27/2006 20:40:00 23.6 2.9 30.9 14.5 23.3 3.1 33.2 13.7 23.2 3.1 31.3 13.7 336 11 347 165 -7.1 0 -6.8 -7.2 02/27/2006 20:50:00 21.9 3.2 33.2 14.9 21.3 3.3 30.6 13.7 21.5 3.5 30.2 13.3 339 12 356 165 -7.1 0 -6.8 -7.2 02/27/2006 21:00:00 22.1 3.1 32.1 14.5 21.9 3.1 32.1 13.7 21.8 3.2 30.9 12.6 332 12 336 165 -7 0 -6.8 -7.2 02/27/2006 21:10:00 23.5 2.8 29.8 15.6 23.4 3.1 29.8 12.2 23.5 2.9 29.4 15.6 335 10 329 165 -6.9 0 -6.8 -7 02/27/2006 21:20:00 23.1 3.5 32.1 15.6 22.8 3.6 32.1 14.1 22.8 3.6 34.4 14.5 333 12 335 165 -6.8 0 -6.6 -7 02/27/2006 21:30:00 22.2 2.7 30.2 16.8 21.2 3.1 30.9 13 21.9 2.8 30.9 14.9 338 12 344 165 -6.9 0 -6.8 -7 02/27/2006 21:40:00 24 3.3 31.8 16.1 23.5 3.8 31.8 13.3 23.7 3.3 32.1 14.9 335 11 347 165 -6.8 0 -6.6 -7 02/27/2006 21:50:00 26.2 2.8 33.2 19.1 25.6 3.3 34 17.2 26.2 3.1 34 18.3 338 11 344 165 -6.8 0 -6.6 -6.8 02/27/2006 22:00:00 25.1 2.8 34 18.3 24.8 3.3 34.8 13.3 25.2 3.1 35.5 17.9 336 9 338 165 -6.8 0 -6.6 -6.8 02/27/2006 22:10:00 24.9 3.3 32.4 13.3 24.7 3.6 33.2 14.1 24.9 3.5 32.9 12.2 339 8 339 165 -6.8 0 -6.6 -6.8 02/27/2006 22:20:00 24.4 2.9 32.1 17.9 24.1 3.2 32.1 16.1 24.6 3.2 32.1 16.8 339 9 331 165 -6.8 0 -6.6 -6.8 02/27/2006 22:30:00 22.8 2.6 29.8 15.3 22.5 2.8 31.3 13 22.8 2.7 32.1 16.4 336 10 337 165 -6.9 0 -6.6 -7 02/27/2006 22:40:00 23.9 2.7 30.9 17.2 23.6 2.8 30.6 16.4 23.7 2.8 31.8 16.8 339 9 351 165 -6.9 0 -6.8 -7 02/27/2006 22:50:00 24.6 2.6 30.9 17.6 23.8 3.5 31.3 13 24.7 2.7 32.1 16.4 341 9 334 165 -6.9 0 -6.8 -7 02/27/2006 23:00:00 23.7 2.8 33.2 17.9 23.6 3.1 34 16.8 23.4 3.2 31.3 16.1 337 8 339 165 -7.1 0 -6.8 -7.2 02/27/2006 23:10:00 23.8 3.1 34 16.8 23.6 3.1 33.2 16.1 23.6 3.2 33.6 16.4 339 8 352 165 -7.1 0 -6.8 -7.2 02/27/2006 23:20:00 23.2 2.8 31.3 16.1 23.1 3.1 32.4 15.6 22.8 3.1 31.3 14.1 340 8 346 165 -7.1 0 -6.8 -7.2 02/27/2006 23:30:00 23.4 2.7 29.4 16.1 23.1 3.3 29.8 14.1 23 2.9 31.3 14.5 341 8 353 165 -7.1 0 -6.8 -7.2 02/27/2006 23:40:00 22.9 2.3 29.8 16.1 22.4 3.2 30.9 12.2 22.6 2.4 30.2 14.5 342 8 345 165 -7.1 0 -6.8 -7.2 02/27/2006 23:50:00 22.1 2 27.1 15.6 21.1 2.7 28.3 13.3 21.8 2.3 28.7 14.1 343 9 351 165 -7 0 -6.8 -7.2 02/28/2006 00:00:00 19.8 2.3 25.2 14.1 19.1 2.9 25.6 11.1 19.5 2.6 26 13 339 10 328 165 -6.9 0 -6.6 -7 02/28/2006 00:10:00 20.6 2.4 29.4 14.1 20 2.8 29.4 13.3 20.2 2.6 30.6 14.1 341 9 336 165 -6.9 0 -6.8 -7 02/28/2006 00:20:00 22.1 2.7 28.7 15.3 21.3 3.3 28.7 12.6 21.8 2.8 28.7 15.3 338 11 342 165 -6.9 0 -6.8 -6.8 02/28/2006 00:30:00 23.6 2.5 29.8 16.8 23.3 2.8 30.2 15.3 23.6 2.7 30.9 16.8 342 8 347 165 -6.8 0 -6.6 -6.8 02/28/2006 00:40:00 21.6 2.4 27.9 16.1 21.3 2.6 27.9 13.7 21.1 2.6 27.5 15.6 342 8 349 165 -6.8 0 -6.6 -6.8 02/28/2006 00:50:00 19.4 2.2 26.3 14.9 19.2 2.7 27.1 11.5 18.8 2.3 25.2 13.7 341 9 347 165 -6.8 0 -6.6 -6.8 02/28/2006 01:00:00 18.5 2.5 24.4 13.3 18.1 2.6 25.6 11.5 17.7 2.8 25.6 10.7 338 11 340 165 -6.8 0 -6.6 -6.8 02/28/2006 01:10:00 20 2.1 26.8 15.3 19.1 2.8 24.8 11.5 19.5 2.2 25.6 12.6 340 11 358 165 -6.8 0 -6.6 -6.8 02/28/2006 01:20:00 21.6 2.5 27.5 14.5 21.1 2.6 27.9 14.5 21.4 2.7 29.1 14.1 341 8 346 165 -6.8 0 -6.6 -6.8 02/28/2006 01:30:00 18.2 3.1 28.3 11.5 17.9 3.2 27.9 8.8 17.9 3.3 29.8 10.7 338 10 332 165 -6.8 0 -6.6 -6.8 02/28/2006 01:40:00 18.5 2.4 26.8 13 17.2 2.6 24 9.9 18.2 2.7 26.3 11.8 342 12 350 165 -6.8 0 -6.6 -6.8 02/28/2006 01:50:00 19.7 3.1 28.3 14.1 19 3.5 27.1 10.3 19.4 3.2 27.9 11.5 342 10 347 165 -6.7 0 -6.6 -6.8 02/28/2006 02:00:00 16.5 2.7 24.8 9.5 15.8 2.6 24.8 7.6 16.1 2.9 24.4 9.1 337 12 341 165 -6.8 0 -6.6 -6.8 02/28/2006 02:10:00 17.4 2.5 25.6 12.2 16.5 2.9 25.2 8.8 17.1 2.7 25.6 11.5 343 11 335 165 -6.6 0 -6.4 -6.8 02/28/2006 02:20:00 17.9 2.1 24.4 13.3 16.5 2.7 23.7 9.9 17.3 2.1 23.3 12.2 347 11 336 165 -6.6 0 -6.6 -6.8 02/28/2006 02:30:00 15.7 2.4 21.4 10.3 15.3 2.5 21 9.9 14.9 2.4 21 9.9 334 15 347 165 -6.7 0 -6.6 -6.8 02/28/2006 02:40:00 17.7 2.5 25.2 12.2 17.3 2.6 24 11.1 17.4 2.7 23.7 11.5 339 10 352 165 -6.8 0 -6.6 -6.8 02/28/2006 02:50:00 19.4 2.4 26.8 13.3 18.5 2.5 26 11.8 18.7 2.6 26 13 339 12 332 165 -6.9 0 -6.8 -7 02/28/2006 03:00:00 19.2 2.7 26.8 12.6 18.6 2.7 26.8 11.8 18.7 2.9 27.1 12.2 337 15 335 165 -7.1 0 -6.8 -7.2 02/28/2006 03:10:00 20.5 2.8 27.1 11.8 19.9 2.8 27.5 11.1 20.3 2.9 27.9 10.7 342 9 339 165 -7.2 0 -7 -7.2 02/28/2006 03:20:00 19.3 2.3 26 13.7 18.9 2.5 26.3 12.6 18.4 2.4 24.4 11.8 332 13 348 165 -7.3 0 -7 -7.4 02/28/2006 03:30:00 21.2 2.8 29.8 15.3 20.8 2.9 29.8 13.7 21.1 3.1 30.2 14.9 335 10 344 165 -7.2 0 -7 -7.4 02/28/2006 03:40:00 19.4 2 25.2 13.3 19.3 2.1 25.2 14.1 18.8 1.9 23.7 12.6 322 11 320 165 -7.5 0 -7.2 -7.6 02/28/2006 03:50:00 19.4 2.7 27.1 13.3 19.2 2.7 26.3 13 18.3 2.8 27.1 12.6 322 12 325 165 -7.6 0 -7.4 -7.6 02/28/2006 04:00:00 18.2 2.6 24.4 11.8 18.1 2.6 24 11.8 17.4 2.6 23.7 11.1 323 11 343 165 -7.7 0 -7.4 -7.9 02/28/2006 04:10:00 21.6 2.5 29.4 15.3 21.5 2.5 29.4 14.9 20.6 2.7 29.1 13 317 8 326 165 -7.7 0 -7.4 -8.1 02/28/2006 04:20:00 23.3 2.5 32.1 16.4 23.1 2.5 31.8 16.1 22.8 2.5 29.8 16.1 321 10 318 165 -7.5 0 -7.4 -7.6 02/28/2006 04:30:00 24.1 2.4 29.1 15.6 23.9 2.5 29.1 15.6 23.1 2.9 30.9 13 319 9 312 165 -7.7 0.1 -7.4 -8.1 02/28/2006 04:40:00 25.4 2.2 31.8 19.9 25.2 2.2 31.8 19.9 24.8 2.3 32.4 18.7 317 6 312 165 -8.1 0.1 -7.6 -8.5 02/28/2006 04:50:00 24.2 2.6 32.1 17.2 24 2.6 32.1 17.6 23.4 2.8 30.6 17.2 318 9 322 165 -8.1 0.1 -7.6 -8.3 02/28/2006 05:00:00 22.8 2.2 31.8 17.2 22.6 2.1 30.6 16.8 21.2 2.5 28.3 14.5 315 9 313 165 -8.1 0.1 -7.9 -8.5 02/28/2006 05:10:00 20.8 2.6 30.9 13.3 20.6 2.6 30.2 11.1 19.9 2.9 30.6 12.2 323 17 347 165 -7.8 0.3 -7.4 -8.5 02/28/2006 05:20:00 18 2.2 25.2 11.5 17.8 2.1 23.3 11.5 17 2.2 22.9 11.1 327 15 1 165 -8.2 0.2 -7.4 -8.5 02/28/2006 05:30:00 18.2 2.3 25.2 11.8 18 2.4 26 11.5 17.8 2.4 24.8 11.1 334 11 336 165 -7.4 0 -7.2 -7.6 02/28/2006 05:40:00 20.5 2.8 27.1 10.7 20.4 2.7 26.8 11.1 18.5 2.8 26 10.7 310 9 307 165 -8 0.3 -7.4 -8.5 02/28/2006 05:50:00 23.3 2 29.1 19.1 23.2 2 29.1 18.3 22.6 2.2 28.3 16.1 314 5 311 165 -8.6 0.2 -8.1 -9.1 02/28/2006 06:00:00 23.3 2.4 33.2 16.8 23.2 2.4 32.9 16.8 22.1 2.6 32.9 16.1 316 8 318 165 -8.8 0 -8.5 -9.1 02/28/2006 06:10:00 20.3 2.3 26.8 13.7 20.3 2.2 26.3 14.5 17.6 2.6 25.2 11.5 313 10 301 165 -9 0 -8.9 -9.3 02/28/2006 06:20:00 22.8 2.3 30.9 17.6 22.6 2.3 30.6 16.8 21 2.6 28.3 13 313 9 311 165 -8.9 0.1 -8.5 -9.3 02/28/2006 06:30:00 21.5 2.7 30.2 11.1 21.4 2.7 30.2 11.1 19.2 2.9 30.6 9.9 310 9 317 165 -8.4 0.1 -8.1 -8.7 02/28/2006 06:40:00 19.9 2.1 28.3 14.1 19.7 2.1 27.5 14.1 18.1 2.3 24 10.7 313 9 310 165 -8.8 0.1 -8.1 -8.9 02/28/2006 06:50:00 20.8 2.7 27.1 12.6 20.7 2.7 27.1 12.6 19 2.4 27.5 12.2 313 11 310 165 -8.7 0.1 -8.3 -8.9 02/28/2006 07:00:00 20.1 2.7 27.9 13 19.8 2.9 27.1 12.6 18.7 2.7 27.1 12.2 323 17 307 165 -8.2 0.1 -7.9 -8.5 02/28/2006 07:10:00 18.1 2.7 24.8 11.1 17.5 2.6 24.4 11.1 17.3 2.8 24.4 11.8 338 12 353 165 -7.7 0.1 -7.4 -8.1 02/28/2006 07:20:00 15.2 2.2 22.1 10.3 14.9 2.3 22.1 9.5 14.2 2.2 22.9 9.1 334 13 332 165 -7.8 0.1 -7.4 -8.1 02/28/2006 07:30:00 18.1 3.1 23.7 10.7 17.9 2.9 23.7 8.4 14.8 2.7 21.8 7.2 306 12 301 165 -8.5 0.4 -7.6 -9.1 02/28/2006 07:40:00 20.5 2.2 26 14.5 20.3 2.2 25.2 14.5 17.6 2.3 24.4 11.8 306 8 291 165 -8.9 0.2 -8.5 -9.3 02/28/2006 07:50:00 17.1 2.5 25.6 10.3 17 2.5 26.3 10.7 15.6 2.4 25.6 9.9 316 12 316 165 -8.8 0.1 -8.5 -9.1 02/28/2006 08:00:00 16.9 2.2 22.1 11.1 16.8 2.2 21.4 11.5 15.7 2.5 22.1 9.9 318 9 316 165 -8.9 0 -8.5 -8.9 02/28/2006 08:10:00 17.1 2.5 26.3 8.8 17 2.5 26.3 9.5 16.2 2.6 21.8 8.4 323 15 304 165 -8.4 0.2 -8.1 -8.9 02/28/2006 08:20:00 19.3 2.5 24.4 12.6 19.2 2.4 24.4 12.2 17.6 2.4 24 12.2 312 9 296 165 -8.3 0.1 -8.1 -8.7 02/28/2006 08:30:00 19.6 2.4 27.1 13 19.4 2.3 26.3 12.2 17.2 2.5 23.7 11.8 308 8 293 165 -8.4 0.1 -8.1 -8.5 02/28/2006 08:40:00 18 2.1 23.7 13 17.8 2 22.9 13 16 1.9 21 11.5 310 9 302 165 -8.5 0.1 -8.3 -8.5 02/28/2006 08:50:00 16.3 2 22.6 9.5 16.1 2.1 22.1 9.5 14.9 1.9 20.6 9.5 320 15 301 165 -8.2 0.1 -8.1 -8.7 02/28/2006 09:00:00 16 2.4 24 9.9 15.9 2.4 23.3 8.8 14.9 2.2 22.6 9.5 321 17 0 165 -8.3 0.1 -8.1 -8.5 02/28/2006 09:10:00 15 2.1 22.9 9.9 14.8 2 19.9 9.9 14.2 2.3 21 8.8 324 15 5 165 -8.1 0.1 -8.1 -8.5 02/28/2006 09:20:00 15.4 2.2 21 9.5 15.2 2.1 20.6 9.5 13.9 1.9 18.3 9.1 315 12 303 165 -8 0 -7.6 -8.3 02/28/2006 09:30:00 17.4 1.9 22.9 13.3 17.3 1.9 22.9 13.3 15.6 2.2 21 9.5 311 8 306 165 -8.1 0 -8.1 -8.3 02/28/2006 09:40:00 18.1 1.8 22.1 11.8 18 1.9 22.1 11.1 16 2.2 21.4 11.1 310 8 310 165 -8.3 0 -8.1 -8.5 02/28/2006 09:50:00 18.2 1.7 22.6 14.5 18.1 1.7 22.6 14.1 16.5 2 22.9 12.2 311 8 306 165 -8.3 0 -8.1 -8.5 02/28/2006 10:00:00 18.6 1.8 24 13.7 18.5 1.7 25.2 13.7 16.6 2.1 23.3 11.5 310 8 327 165 -8.4 0 -8.1 -8.5 02/28/2006 10:10:00 20.2 2.1 27.1 14.5 20 2.1 27.1 14.5 18.4 2.4 26.8 11.5 311 7 313 165 -8.5 0 -8.3 -8.5 02/28/2006 10:20:00 17.2 2 22.9 12.2 17.1 1.9 22.6 12.6 15.1 2.2 22.6 8.4 309 7 305 165 -8.4 0 -8.3 -8.5 02/28/2006 10:30:00 17.7 2.2 23.3 12.2 17.6 2.1 23.3 12.2 15.8 2.4 22.9 9.9 312 8 308 165 -8.6 0 -8.5 -8.9 02/28/2006 10:40:00 18 2.2 23.3 11.8 17.9 2.2 22.9 11.8 14.3 2.4 21.4 7.2 304 7 307 165 -8.8 0 -8.5 -8.9 02/28/2006 10:50:00 17 1.7 21 11.1 16.8 1.7 20.6 11.1 13.5 1.9 19.1 9.1 304 5 316 165 -8.6 0 -8.5 -8.9 02/28/2006 11:00:00 17.2 2 24 9.9 17 2 24.4 9.9 14.7 2.2 20.2 9.1 307 9 298 165 -8.4 0.1 -8.1 -8.7 02/28/2006 11:10:00 16.9 1.9 23.7 11.1 16.7 1.9 23.3 10.7 14 2 19.9 8.8 305 8 306 165 -8 0.1 -7.6 -8.5 02/28/2006 11:20:00 17.1 2.1 22.1 11.1 16.9 2 22.1 11.1 14 2.5 21.8 8.8 305 9 295 165 -8.1 0 -7.6 -8.3 02/28/2006 11:30:00 17.5 2.2 23.3 12.6 17.4 2.1 22.9 11.5 15.6 2.3 24.4 10.3 310 7 305 165 -8 0 -7.9 -8.1 02/28/2006 11:40:00 17.1 2 22.9 11.8 17 2 22.6 11.1 15.8 2 22.1 9.9 314 8 312 165 -7.9 0 -7.6 -8.1 02/28/2006 11:50:00 16.4 2.1 22.1 8.8 16.3 2.2 21.8 8 14.7 2.2 21 9.5 312 9 309 165 -7.4 0.2 -6.8 -7.9 02/28/2006 12:00:00 16.7 2 24.4 11.5 16.6 2 24.4 10.7 15 2.2 22.1 10.3 313 9 304 165 -7.5 0 -7.2 -7.6 02/28/2006 12:10:00 18 2.2 23.7 12.6 17.8 2.2 23.3 13.3 16.6 2.6 24.4 9.9 316 9 319 165 -7.4 0.1 -7 -7.6 02/28/2006 12:20:00 19.3 1.8 23.3 13.3 19.2 1.7 22.9 13 18.6 2.1 22.9 11.1 319 8 316 165 -7.3 0 -7 -7.4 02/28/2006 12:30:00 17.6 1.7 24.8 13.3 17.5 1.7 25.2 13.3 16.5 2.1 21.8 11.1 315 9 314 165 -7 0.1 -6.8 -7.2 02/28/2006 12:40:00 16.1 2.7 22.9 9.5 15.4 2.8 24 9.5 15.6 2.8 22.6 10.3 335 16 347 165 -6.7 0.1 -6.4 -6.8 02/28/2006 12:50:00 15.6 1.9 21.4 11.5 15.5 1.8 21.4 11.5 14.5 2 19.9 9.5 316 11 307 165 -6.8 0.1 -6.6 -7 02/28/2006 13:00:00 15.5 1.8 19.5 9.5 15.4 1.8 19.5 9.5 14.8 1.9 20.6 9.1 320 10 314 165 -6.7 0 -6.6 -6.8 02/28/2006 13:10:00 16.7 2 21 10.3 16.6 2 21.8 11.1 15.3 2.4 22.9 9.5 316 9 323 165 -6.7 0.2 -6.4 -6.8 02/28/2006 13:20:00 16.4 1.8 24 11.5 16.3 1.8 24.4 11.5 15.7 1.8 22.9 10.3 319 8 316 165 -6.7 0 -6.6 -7 02/28/2006 13:30:00 15.3 1.9 20.6 11.5 15.2 1.9 20.6 10.7 14.5 2.3 21.4 8.4 317 8 319 165 -6.6 0.1 -6.1 -6.8 02/28/2006 13:40:00 15.1 1.4 17.9 10.3 15 1.4 18.7 10.7 14.3 1.7 18.7 9.9 322 11 328 165 -6.4 0 -6.1 -6.6 02/28/2006 13:50:00 15.4 1.9 22.1 10.3 15.3 1.9 21.8 9.5 14.4 2.3 20.6 7.6 317 11 305 165 -6.3 0.2 -6.1 -6.6 02/28/2006 14:00:00 15.1 2 21.8 10.7 15.1 2.1 22.1 10.3 14.3 2 22.6 9.9 318 10 314 165 -6.4 0.1 -5.9 -6.8 02/28/2006 14:10:00 14.9 1.9 19.5 10.3 14.7 1.9 19.5 10.3 14.1 1.9 19.5 9.9 324 13 329 165 -6.1 0 -5.9 -6.4 02/28/2006 14:20:00 14.1 1.8 19.5 8.8 13.7 1.7 18.7 9.1 14 1.9 18.7 6.8 335 12 356 165 -6.2 0.1 -5.9 -6.4 02/28/2006 14:30:00 17.3 2.4 23.7 10.7 16.5 2.6 24.8 9.5 17.6 2.6 25.6 10.3 341 12 341 165 -6.2 0.1 -5.9 -6.4 02/28/2006 14:40:00 14.8 1.7 19.1 9.1 14.6 1.7 19.1 9.1 13.9 1.5 17.9 9.9 325 14 302 165 -6.2 0.2 -5.7 -6.6 02/28/2006 14:50:00 16.5 1.5 20.6 13 16.4 1.5 20.2 12.6 14.4 1.6 18.3 9.5 309 6 305 165 -6.5 0 -5.9 -6.8 02/28/2006 15:00:00 16.1 1.7 20.2 11.5 15.9 1.8 20.2 9.9 14.5 1.8 20.2 9.9 318 17 302 165 -6.4 0.1 -5.9 -6.8 02/28/2006 15:10:00 14.9 1.6 18.3 11.5 14.8 1.6 18.3 11.1 13.7 1.6 19.1 9.5 315 9 309 165 -6.2 0.1 -5.9 -6.6 02/28/2006 15:20:00 15.2 1.5 21.4 11.5 15.1 1.6 21 10.7 14.2 1.7 19.5 9.5 316 10 305 165 -6.3 0.1 -6.1 -6.4 02/28/2006 15:30:00 16.8 1.9 21 11.1 16.6 1.9 20.6 11.8 15.3 1.9 20.6 10.3 312 8 308 165 -6.4 0.1 -6.1 -6.6 02/28/2006 15:40:00 17.6 1.3 22.1 13.3 17.4 1.3 22.6 13 16.1 1.5 19.5 11.5 313 8 302 165 -6.5 0.1 -6.1 -6.8 02/28/2006 15:50:00 16.3 1.8 21 9.9 16.1 1.7 20.6 9.5 15.6 1.9 21 10.3 325 12 315 165 -6.1 0 -5.9 -6.4 02/28/2006 16:00:00 18 2.4 25.6 12.2 17.5 2.6 25.2 11.5 17.1 2.6 25.6 9.9 330 15 328 165 -6 0 -5.7 -6.4 02/28/2006 16:10:00 18.7 2 24 12.2 18.6 1.9 24 12.2 17.5 2 23.7 12.6 314 9 314 165 -6.3 0.2 -5.7 -6.6 02/28/2006 16:20:00 18.3 1.9 24 12.6 18.2 1.9 23.3 13 16.9 2.3 22.1 9.1 313 9 303 165 -6.5 0 -6.4 -6.8 02/28/2006 16:30:00 19.5 2.4 24.8 13.7 19.3 2.4 24.8 13.7 18.8 2.5 24.8 13.3 317 8 310 165 -6.5 0 -6.4 -6.6 02/28/2006 16:40:00 19.3 2 25.2 13.7 19.2 2 24.8 14.1 18.6 1.9 24.4 14.1 320 8 307 165 -6.5 0 -6.4 -6.6 02/28/2006 16:50:00 18.8 1.7 24 14.1 18.7 1.7 24 14.1 18.3 1.7 23.7 13.7 320 8 324 165 -6.5 0 -6.4 -6.8 02/28/2006 17:00:00 18.2 1.7 23.3 13 18.1 1.7 23.3 13 17.6 2 21.8 10.7 318 7 317 165 -6.5 0 -6.4 -6.6 02/28/2006 17:10:00 17.7 1.5 21.8 14.1 17.6 1.5 21.8 13.7 16.9 1.6 21.8 12.6 316 8 319 165 -6.5 0 -6.4 -6.8 02/28/2006 17:20:00 15.9 1.3 19.9 13 15.8 1.2 19.9 13.3 14.7 1.2 18.3 10.3 313 7 307 165 -6.5 0 -6.4 -6.8 02/28/2006 17:30:00 17.1 1.4 22.1 13 17 1.4 21.4 13 15.4 1.7 20.6 11.1 311 6 318 165 -6.8 0.1 -6.6 -7 02/28/2006 17:40:00 17 1.7 22.1 11.8 16.9 1.7 22.1 11.5 15.5 2.2 21 9.5 311 8 311 165 -6.9 0 -6.8 -7.2 02/28/2006 17:50:00 16.9 1.6 21.8 12.6 16.8 1.6 21.8 13 14.5 1.7 20.6 9.9 308 6 312 165 -7.1 0 -6.8 -7.2 02/28/2006 18:00:00 16.7 1.9 21.4 12.6 16.7 1.9 21 12.2 16 2.2 21.8 10.7 317 9 302 165 -7.1 0 -6.8 -7.2 02/28/2006 18:10:00 19.8 2.4 27.1 14.5 19.8 2.4 26.3 14.9 19.7 2.7 26 14.5 322 9 307 165 -7 0 -6.8 -7.2 02/28/2006 18:20:00 17.5 2.1 22.6 13 17.3 2.2 22.6 12.6 17.1 2.1 22.6 13 323 9 312 165 -7.2 0 -6.8 -7.4 02/28/2006 18:30:00 19.8 1.5 23.7 15.6 19.7 1.5 23.3 15.6 19.2 1.5 23.7 15.3 316 6 318 165 -7.4 0.1 -7 -7.6 02/28/2006 18:40:00 19.6 1.5 23.7 15.6 19.5 1.5 23.7 15.6 19.1 1.7 24.8 15.3 317 6 312 165 -7.4 0 -7.2 -7.4 02/28/2006 18:50:00 17.4 2.2 23.3 11.8 17.3 2.2 23.7 11.8 16.2 2.4 21 10.7 313 7 301 165 -7.4 0 -7.2 -7.4 02/28/2006 19:00:00 17.8 1.9 23.3 13 17.7 1.9 22.9 12.6 16.4 2.1 22.1 11.1 313 9 305 165 -7.3 0 -7 -7.4 02/28/2006 19:10:00 18.2 2.4 25.2 12.6 18.1 2.4 24.4 12.2 16.9 2.2 26.3 11.5 315 8 311 165 -7.2 0 -7 -7.4 02/28/2006 19:20:00 18.7 2.3 25.2 14.1 18.6 2.3 25.2 13.7 18.3 2.4 25.6 13 319 7 308 165 -7.2 0.1 -6.8 -7.4 02/28/2006 19:30:00 17.2 1.8 24 13 17 1.8 24.4 13 16.7 1.7 22.1 10.3 318 8 316 165 -7.4 0 -7.2 -7.4 02/28/2006 19:40:00 16.2 1.3 21.4 12.6 16.1 1.3 21 12.6 15.8 1.5 19.9 11.8 320 7 310 165 -7.4 0 -7.2 -7.4 02/28/2006 19:50:00 15.9 1.7 21 11.5 15.8 1.7 20.6 11.5 14.6 1.9 20.2 8.8 314 9 314 165 -7.2 0 -7 -7.4 02/28/2006 20:00:00 16.3 1.8 22.6 9.9 16.2 1.8 21.8 9.9 14.8 1.8 19.1 10.3 313 8 305 165 -7.3 0 -7.2 -7.4 02/28/2006 20:10:00 17.4 1.3 22.1 13 17.3 1.3 22.1 13 16.1 1.5 20.6 12.6 312 6 315 165 -7.2 0 -7 -7.4 02/28/2006 20:20:00 16.1 1.6 19.5 12.2 16 1.7 19.9 11.8 15 1.7 19.9 10.3 314 6 309 165 -7.4 0 -7.2 -7.4 02/28/2006 20:30:00 15.7 1.4 19.5 12.2 15.6 1.4 19.5 12.2 15 1.5 18.7 10.7 315 5 298 165 -7.4 0.1 -7.2 -7.4 02/28/2006 20:40:00 15.3 1.7 18.7 10.3 15.2 1.7 19.1 9.9 14.3 1.6 17.9 10.3 312 6 312 165 -7.3 0 -7 -7.4 02/28/2006 20:50:00 14.8 1.9 19.1 10.3 14.6 1.8 18.7 10.3 13.3 1.9 18.7 8.4 311 8 294 165 -7.1 0 -6.8 -7.2 02/28/2006 21:00:00 13.9 1.7 18.7 10.7 13.8 1.7 17.9 10.7 12.8 1.7 17.6 8.4 314 11 301 165 -6.9 0 -6.6 -7 02/28/2006 21:10:00 15.2 2.2 21 8.8 15.1 2.2 20.2 9.1 13.3 2 20.2 9.1 310 9 297 165 -6.7 0 -6.6 -6.8 02/28/2006 21:20:00 18.6 2 25.2 13 18.5 2 24.8 13 16.9 1.9 23.3 12.6 311 8 302 165 -6.8 0 -6.6 -7 02/28/2006 21:30:00 16.6 1.8 21.4 11.8 16.5 1.8 21.4 12.2 15.8 1.7 20.6 11.8 316 8 310 165 -6.7 0 -6.4 -6.8 02/28/2006 21:40:00 17.1 1.6 21 13 17 1.6 21 12.6 14.6 2 20.2 9.9 308 6 307 165 -6.8 0.1 -6.6 -7 02/28/2006 21:50:00 17.5 1.6 21.4 13 17.4 1.6 21 12.6 14.9 2 20.2 9.9 307 5 304 165 -7.1 0 -6.8 -7.4 02/28/2006 22:00:00 18.6 1.3 21.8 14.1 18.5 1.3 21.8 14.1 17.6 1.5 21 12.2 312 5 304 165 -7.2 0 -7 -7.2 02/28/2006 22:10:00 19.8 1.1 22.1 16.4 19.7 1.1 22.1 16.1 19.8 1.2 23.3 16.4 319 4 316 165 -7.2 0 -7 -7.4 02/28/2006 22:20:00 18.4 1.5 21.8 13 18.3 1.5 22.1 12.6 17.9 1.5 21.8 12.6 316 6 316 165 -7.2 0 -6.8 -7.2 02/28/2006 22:30:00 18.6 1.5 22.1 14.5 18.5 1.5 22.1 13.7 17.8 1.7 23.7 13 314 5 321 165 -7.1 0 -6.8 -7.2 02/28/2006 22:40:00 17.2 1.2 21.4 14.5 17.1 1.2 21 14.5 15.7 1.3 22.1 12.6 312 5 325 165 -7.1 0 -7 -7.2 02/28/2006 22:50:00 16 1.6 19.9 11.8 15.9 1.6 19.9 11.8 14.6 1.6 19.5 9.5 312 6 310 165 -6.9 0.1 -6.6 -7.2 02/28/2006 23:00:00 16.3 1.7 20.6 11.8 16.2 1.7 19.9 11.8 15.6 1.7 19.5 10.3 314 7 311 165 -6.6 0 -6.6 -6.8 02/28/2006 23:10:00 16.1 1.8 20.2 11.1 16 1.8 19.9 10.7 15.6 2.1 20.6 11.1 321 9 326 165 -6.5 0.1 -6.4 -6.8 02/28/2006 23:20:00 17 1.8 20.6 12.2 17 1.9 21 11.5 16.5 1.9 21 11.5 336 9 331 165 -6.4 0 -6.1 -6.6 02/28/2006 23:30:00 16.6 1.9 21.4 12.2 15.9 2.2 21.4 9.9 15.6 2.4 21.8 9.9 343 9 352 165 -6.4 0 -6.1 -6.8 02/28/2006 23:40:00 18 1.8 23.3 12.2 17.7 2.1 24 11.1 17 2 22.6 11.1 340 7 345 165 -6.4 0 -6.1 -6.6 02/28/2006 23:50:00 17 2.9 22.6 9.9 16.4 3.3 24 9.1 16.3 3.1 22.1 9.5 340 10 343 165 -6.4 0 -6.1 -6.6 03/01/2006 00:00:00 13 2.3 18.7 8 12.8 2.3 19.5 8 12.2 2.3 19.5 8 323 14 319 165 -6.4 0 -6.1 -6.6 03/01/2006 00:10:00 11.4 1.9 17.6 7.2 11.3 1.9 16.8 6.5 10.7 2.2 17.2 5.3 326 15 349 165 -6.5 0 -6.4 -6.8 03/01/2006 00:20:00 12.6 1.8 17.2 8.4 12.5 1.8 16.8 7.2 12.1 2.2 17.6 6.8 324 13 326 165 -6.4 0.1 -6.1 -6.6 03/01/2006 00:30:00 11.5 1.6 16.8 6.8 11.3 1.7 17.2 6.8 10.8 1.7 16.4 5.7 329 13 327 165 -6.7 0 -6.4 -6.8 03/01/2006 00:40:00 11.5 1.4 17.2 8 11 1.7 16.8 5.7 11.1 1.3 16.8 7.6 343 12 10 165 -6.8 0.1 -6.6 -7 03/01/2006 00:50:00 12.7 1.7 17.9 8.4 11.1 2.2 18.3 6.5 12.8 1.8 17.6 6.1 350 11 350 165 -6.9 0 -6.8 -7.2 03/01/2006 01:00:00 12 1.3 15.6 8.8 10.9 2 15.6 5.7 11.7 1.3 14.9 8.8 345 12 2 165 -7.2 0 -6.8 -7.4 03/01/2006 01:10:00 12.5 1.6 17.2 8.4 11.3 2.5 17.6 5.3 12.4 1.5 17.6 8.4 350 11 343 165 -7.2 0 -7 -7.4 03/01/2006 01:20:00 11.9 1.6 16.4 8.8 10.6 2.6 16.4 4.9 11.7 1.8 17.2 8 343 17 329 165 -7.2 0 -7 -7.4 03/01/2006 01:30:00 13.8 1.7 18.3 10.3 12.1 2.4 17.9 6.5 13.8 1.7 18.7 10.3 348 9 0 165 -7.3 0 -7 -7.4 03/01/2006 01:40:00 11.5 1.7 16.1 6.8 9.8 2.1 15.3 5.7 11.3 1.9 16.1 6.5 352 11 352 165 -7.4 0 -7.2 -7.4 03/01/2006 01:50:00 13 1.5 17.2 8 11.6 2.1 16.8 6.5 13.1 1.7 18.7 7.2 346 12 7 165 -7.4 0 -7.2 -7.6 03/01/2006 02:00:00 13 1.7 17.2 9.1 12.3 2.2 17.6 6.5 12.8 1.8 18.7 7.6 341 12 338 165 -7.5 0 -7.2 -7.6 03/01/2006 02:10:00 14.8 1.8 19.9 10.7 14.2 2.3 19.9 8.4 14.5 1.9 20.2 10.3 342 10 347 165 -7.5 0 -7.2 -7.6 03/01/2006 02:20:00 17 1.7 21 13 17.1 1.9 20.6 10.3 16.9 1.8 21.4 12.2 341 7 336 165 -7.3 0 -7.2 -7.4 03/01/2006 02:30:00 14.1 1.5 19.1 10.7 14.1 1.6 18.7 10.3 13.8 1.5 18.7 9.9 335 8 336 165 -7.4 0 -7.2 -7.6 03/01/2006 02:40:00 14.1 1.6 17.9 9.9 14 1.7 18.3 9.9 14 1.6 18.3 10.3 336 9 336 165 -7.4 0 -7.2 -7.4 03/01/2006 02:50:00 11.5 1.3 15.6 7.6 11.4 1.4 16.1 7.6 11.2 1.4 15.6 6.8 336 10 339 165 -7.5 0 -7.2 -7.6 03/01/2006 03:00:00 13.3 1.7 18.3 10.3 13.3 1.9 17.9 9.1 13.1 1.9 17.9 9.5 336 8 321 165 -7.3 0 -7 -7.4 03/01/2006 03:10:00 13 1.5 16.4 8 12.8 1.7 17.2 5.7 12.6 1.5 16.8 7.6 336 10 326 165 -7.3 0 -7.2 -7.4 03/01/2006 03:20:00 12 1.5 16.1 8.8 10.8 2.3 16.4 5.3 11.9 1.5 16.8 8 347 11 342 165 -7.3 0 -7.2 -7.4 03/01/2006 03:30:00 11.9 1.7 18.7 7.6 11.4 2.5 18.7 5.7 11.7 1.9 16.8 6.5 344 9 340 165 -7.4 0 -7.2 -7.6 03/01/2006 03:40:00 11 2.1 16.8 6.8 10.5 2.1 17.2 5.7 10.8 2.3 17.2 7.2 338 11 330 165 -7.2 0 -7 -7.4 03/01/2006 03:50:00 10.7 1.7 15.3 6.8 10 1.7 15.6 5.7 10.6 1.9 15.3 6.5 333 15 357 165 -7.2 0 -7 -7.2 03/01/2006 04:00:00 11.1 1.9 16.1 6.8 11 2 15.6 6.1 10.9 2.1 16.1 6.1 331 13 350 165 -7.2 0 -7 -7.4 03/01/2006 04:10:00 11.3 1.9 16.8 6.8 11.2 2 17.6 6.5 11.1 1.9 16.1 7.2 332 12 343 165 -7.1 0 -6.8 -7.2 03/01/2006 04:20:00 10.4 1.3 13.7 6.5 10.2 1.4 14.1 6.5 10 1.4 13 6.5 333 13 343 165 -7.2 0 -6.8 -7.4 03/01/2006 04:30:00 9.1 1.6 13.3 4.6 8.5 1.6 13.3 4.2 8.8 1.6 14.1 4.9 337 15 3 165 -7.1 0 -6.8 -7.4 03/01/2006 04:40:00 10.3 1.7 15.6 5.3 10.1 2 16.1 5.3 10 1.9 15.3 5.7 335 13 348 165 -7.1 0 -6.8 -7.2 03/01/2006 04:50:00 10.2 1.6 15.3 6.8 10 1.7 14.9 5.7 10.1 1.7 15.3 6.8 332 14 349 165 -7.1 0 -6.8 -7.2 03/01/2006 05:00:00 12 1.3 16.4 8 11.9 1.3 16.1 7.6 11 1.3 14.5 7.6 316 13 291 165 -7 0 -6.8 -7.2 03/01/2006 05:10:00 13.2 1.7 18.3 9.5 13.1 1.7 17.9 9.1 12.2 1.5 16.1 8 319 15 300 165 -6.9 0 -6.8 -7.2 03/01/2006 05:20:00 13.8 1.7 17.9 8.8 13.7 1.8 18.3 9.1 13.4 1.7 17.2 8.8 332 13 304 165 -7.1 0 -6.8 -7.2 03/01/2006 05:30:00 13.9 1.7 17.6 9.1 13.7 1.9 17.9 8.8 14 1.8 18.7 9.5 339 10 349 165 -7.1 0 -6.8 -7.2 03/01/2006 05:40:00 12.9 1.6 18.3 8.8 12.7 1.9 18.7 6.8 12.4 1.7 17.9 8 341 9 346 165 -7.1 0 -6.8 -7.2 03/01/2006 05:50:00 12.5 1.7 17.9 8 12 2.3 17.2 4.9 12.3 1.9 17.2 6.8 341 11 349 165 -6.9 0.1 -6.6 -7.2 03/01/2006 06:00:00 11 1.9 17.2 6.8 10.9 2.1 17.6 5.7 10.2 2.2 17.6 5.3 334 12 334 165 -7 0 -6.8 -7.2 03/01/2006 06:10:00 8.8 1.5 13 5.3 8.5 1.7 12.6 5.3 8.1 1.7 11.8 4.2 335 12 343 165 -7.2 0 -7 -7.4 03/01/2006 06:20:00 8.6 1.3 12.6 5.7 8.5 1.4 12.2 5.3 7.8 1.4 12.2 4.6 326 19 291 165 -7.2 0 -6.8 -7.2 03/01/2006 06:30:00 9.6 1.3 13.3 6.1 9.6 1.4 13.3 6.5 8.5 1.6 12.2 3.8 325 13 304 165 -7.2 0 -6.8 -7.4 03/01/2006 06:40:00 8.6 1.3 12.6 3.8 8.5 1.3 12.6 4.2 7.7 1.6 11.5 2.6 329 13 6 165 -7.3 0 -7.2 -7.4 03/01/2006 06:50:00 8.1 1.3 12.6 4.6 8 1.3 12.6 4.2 7.1 1.3 11.8 3.4 330 17 330 165 -7.5 0 -7.2 -7.6 03/01/2006 07:00:00 8.5 1.5 13.3 4.2 8.3 1.6 13.3 3.8 7.6 1.5 11.8 3.8 323 17 305 165 -7.4 0 -7.2 -7.6 03/01/2006 07:10:00 8 1.5 11.8 3.4 7.6 1.4 11.1 3.4 7 1.6 10.3 1.5 333 17 350 165 -7.3 0 -7 -7.4 03/01/2006 07:20:00 7.7 1.7 12.2 3.8 7.4 1.6 11.8 3.8 6.8 1.7 11.5 3 333 15 347 165 -7.3 0.1 -7 -7.4 03/01/2006 07:30:00 9.6 1.5 13.7 5.3 8.6 1.7 13.7 4.9 8.6 1.6 12.2 4.2 348 10 345 165 -7.2 0 -7 -7.2 03/01/2006 07:40:00 9.1 1.7 14.1 4.9 8.5 2 14.9 3.8 8.7 1.7 13.7 4.2 345 10 357 165 -7.1 0.1 -6.8 -7.2 03/01/2006 07:50:00 8.8 1.6 13.7 4.6 8.1 1.8 13.3 3.8 7.9 1.6 13 3.4 345 12 354 165 -7.1 0 -6.8 -7.2 03/01/2006 08:00:00 7.7 1.7 12.2 4.2 6.7 1.9 12.6 3.4 7.2 2.1 11.5 0.4 344 17 343 165 -6.9 0 -6.8 -7.2 03/01/2006 08:10:00 6.6 1.7 9.9 3 6.2 1.7 10.3 2.3 5.9 1.7 9.1 2.6 339 15 346 165 -6.9 0 -6.8 -7 03/01/2006 08:20:00 5.8 1.8 10.7 3 5.3 1.9 10.3 1.5 5 2.2 10.3 0.4 344 17 0 165 -6.8 0 -6.6 -7 03/01/2006 08:30:00 8.2 1.3 11.8 5.7 7.4 1.5 11.8 4.6 7.3 1.2 10.3 4.2 347 12 345 165 -6.7 0 -6.6 -6.8 03/01/2006 08:40:00 7 1.7 11.5 2.6 6 1.7 11.8 2.3 6.5 1.8 11.5 1.1 351 16 349 165 -6.4 0.1 -6.1 -6.6 03/01/2006 08:50:00 4.3 1.4 8.4 1.9 3.7 1.6 8 1.1 3.6 1.5 8 0.7 349 22 345 165 -6 0 -5.9 -6.4 03/01/2006 09:00:00 6.2 1.3 10.3 3.4 5.5 1.2 9.1 2.6 5.6 1.1 9.5 3 345 12 4 165 -5.8 0.1 -5.5 -6.1 03/01/2006 09:10:00 7 1.3 9.9 3.4 6.3 1.4 9.5 3 6.5 1.4 9.9 2.6 346 8 353 165 -5.7 0 -5.5 -5.7 03/01/2006 09:20:00 8 1.5 12.2 4.9 7.4 1.8 12.2 3.4 7.6 1.4 12.2 4.9 346 9 351 165 -5.4 0 -5.3 -5.7 03/01/2006 09:30:00 9 1.1 11.5 4.9 8.5 1.7 11.5 3.8 8.9 1.1 11.5 6.1 344 10 338 165 -5.4 0.1 -5.3 -5.7 03/01/2006 09:40:00 8.1 1.2 11.5 3 7.3 1.5 11.1 2.6 7.4 1.4 10.7 3 349 10 338 165 -5.2 0 -5 -5.5 03/01/2006 09:50:00 7.6 1.5 13 3.8 7.2 1.5 11.5 3.4 6.9 1.5 11.1 3.8 346 10 338 165 -5 0.1 -4.6 -5.3 03/01/2006 10:00:00 8.4 1.6 13 4.9 7.5 2.2 13.3 3.4 7.9 1.7 13.3 2.6 352 11 345 165 -4.8 0 -4.6 -5 03/01/2006 10:10:00 8.9 1.5 12.6 5.7 8.2 2 13 4.2 8.2 1.7 14.1 3.8 348 9 347 165 -4.7 0 -4.6 -4.8 03/01/2006 10:20:00 7.8 1.7 13 3.8 7.1 2 12.6 3.4 7.1 1.7 11.5 3.4 345 12 347 165 -4.5 0 -4.4 -4.6 03/01/2006 10:30:00 6.6 1.9 12.2 2.3 5.6 1.8 13 1.5 5.6 2.2 11.1 0.7 0 12 349 165 -4.4 0.3 -3.5 -4.6 03/01/2006 10:40:00 4.9 1.1 7.6 1.9 4.5 1.1 6.8 1.9 4.4 1.2 8 1.5 354 23 6 165 -3.8 0.2 -3.5 -4.2 03/01/2006 10:50:00 3.2 1 5.3 0.7 2.9 0.9 5.3 0.7 2.7 0.9 5.3 0.4 355 30 349 165 -3.5 0.2 -3 -3.9 03/01/2006 11:00:00 2.7 2 6.8 0.4 2.5 1.7 6.5 0.4 2.3 1.7 6.5 0.4 5 53 358 165 -2.7 0.4 -2.1 -3.3 03/01/2006 11:10:00 2.1 0.8 4.2 0.4 2.2 0.8 4.2 0.4 1.9 0.7 4.2 0.4 57 45 99 165 -2.5 0.2 -1.9 -3 03/01/2006 11:20:00 2.2 1 4.2 0.4 2.2 1 4.2 0.4 2 1 3.8 0.4 151 45 87 165 -2.8 0.1 -2.6 -3 03/01/2006 11:30:00 3.6 2.5 9.9 0.4 3.6 2.5 9.5 0.4 2.9 2.1 9.1 0.4 327 58 288 165 -2.4 0.3 -1.9 -2.8 03/01/2006 11:40:00 6.8 1.3 9.5 2.6 6.8 1.3 9.5 3.4 5.8 1.1 8.8 3 290 9 298 165 -3.4 0.2 -2.8 -3.7 03/01/2006 11:50:00 7.9 1.1 11.8 5.3 7.9 1.1 11.5 4.9 6.2 0.9 9.5 4.2 300 7 300 165 -3.8 0 -3.5 -3.9 03/01/2006 12:00:00 6.7 1.7 13 3 6.6 1.6 12.6 3.4 5.9 1.4 10.3 2.6 311 11 291 165 -3.4 0.4 -2.6 -4.2 03/01/2006 12:10:00 6.6 1 8.8 3.8 6.6 0.9 8.8 4.2 5.3 0.9 7.6 3 300 10 296 165 -2.8 0 -2.6 -3 03/01/2006 12:20:00 7.6 1.5 11.5 4.2 7.5 1.6 11.8 4.2 6 1.5 10.3 2.6 296 8 292 165 -3.2 0.2 -2.8 -3.5 03/01/2006 12:30:00 7.8 1.2 10.7 4.6 7.8 1.2 10.7 4.6 6.4 1.3 9.9 3.8 295 9 295 165 -3.4 0 -3 -3.5 03/01/2006 12:40:00 9.4 1 12.2 6.1 9.4 1 11.8 6.1 6.9 0.9 9.1 4.6 299 5 300 165 -3.4 0 -3.3 -3.5 03/01/2006 12:50:00 9.4 1 12.2 7.6 9.4 1 12.2 7.6 7.4 1.2 11.8 4.2 302 6 310 165 -3.5 0 -3.3 -3.5 03/01/2006 13:00:00 9.7 0.7 11.5 7.6 9.6 0.7 11.5 7.6 8.4 1.2 11.1 5.3 310 5 299 165 -3.3 0 -3.3 -3.5 03/01/2006 13:10:00 10.3 0.9 12.2 7.6 10.2 1 11.8 6.8 9.9 1 12.2 7.6 319 4 317 165 -3.2 0.1 -2.6 -3.5 03/01/2006 13:20:00 8.3 0.9 11.1 5.7 8.1 0.8 10.3 5.7 7.8 1 10.7 4.6 317 7 325 165 -2.9 0.1 -2.6 -3 03/01/2006 13:30:00 7.5 1.2 9.9 4.9 7.4 1.1 9.9 4.9 6.6 1.3 10.3 3.8 312 6 322 165 -2.8 0.1 -2.6 -3.3 03/01/2006 13:40:00 5.3 0.8 7.2 3.4 5.3 0.8 7.2 3.4 4.4 0.7 6.5 2.6 299 8 292 165 -2.6 0 -2.6 -2.8 03/01/2006 13:50:00 5.7 0.6 7.2 4.2 5.7 0.6 7.2 4.2 4.7 0.7 6.5 3 303 7 307 165 -2.8 0 -2.6 -3 03/01/2006 14:00:00 5.6 0.5 7.2 4.6 5.6 0.5 7.6 4.6 4.6 0.6 6.5 3 305 6 301 165 -2.6 0.1 -2.6 -2.8 03/01/2006 14:10:00 4.8 0.8 6.5 3 4.8 0.7 6.5 3 3.9 0.7 6.1 2.3 297 9 305 165 -2.5 0 -2.1 -2.6 03/01/2006 14:20:00 5.8 0.7 7.6 3.8 5.8 0.7 7.6 4.2 5.2 0.9 6.8 3.4 287 8 298 165 -2.3 0 -2.1 -2.6 03/01/2006 14:30:00 6.5 0.6 8.4 4.9 6.6 0.6 8 5.3 5.7 0.8 7.6 3.4 289 8 294 165 -2.4 0 -2.1 -2.6 03/01/2006 14:40:00 6.1 1 8.8 3.8 6.1 1 8.4 3.4 5 0.9 7.6 2.6 307 10 286 165 -1.8 0.3 -1.2 -2.6 03/01/2006 14:50:00 5.6 0.7 7.2 3.8 5.5 0.7 7.6 3.8 4.5 0.8 6.8 2.6 301 7 294 165 -1.8 0.1 -1.4 -2.1 03/01/2006 15:00:00 5.6 0.6 8 4.2 5.5 0.6 7.6 4.2 4.6 0.8 6.5 2.6 307 5 299 165 -1.7 0.1 -1.4 -1.9 03/01/2006 15:10:00 4.4 0.5 5.7 2.6 4.3 0.5 5.3 2.6 3.4 0.6 5.7 1.9 301 7 312 165 -1.4 0 -1.2 -1.7 03/01/2006 15:20:00 4.7 0.6 6.1 3.4 4.7 0.5 6.1 3.4 4.1 0.6 5.7 2.3 290 5 291 165 -1.4 0 -1.2 -1.7 03/01/2006 15:30:00 4 0.6 5.3 2.6 4 0.6 5.3 2.6 3.5 0.8 5.3 1.9 292 8 282 165 -1.7 0 -1.4 -1.9 03/01/2006 15:40:00 2.1 0.6 3.8 1.1 2.1 0.6 3.8 1.1 1.7 0.5 3.4 0.7 304 10 291 165 -1.2 0.3 -0.8 -1.7 03/01/2006 15:50:00 1.7 0.4 2.6 0.7 1.8 0.4 3 0.7 1.5 0.4 2.6 0.4 306 12 302 165 -0.3 0.2 0.2 -0.8 03/01/2006 16:00:00 1.6 0.3 2.3 0.7 1.7 0.3 2.3 1.1 1.4 0.3 2.3 0.7 293 9 282 165 -0.5 0 -0.3 -0.8 03/01/2006 16:10:00 1.7 0.5 2.6 0.7 1.8 0.5 2.6 0.4 1.4 0.5 2.3 0.4 291 9 296 165 -0.7 0.2 -0.1 -1 03/01/2006 16:20:00 0.6 0.3 1.9 0.4 0.7 0.4 1.5 0.4 0.6 0.3 1.5 0.4 291 33 294 165 0.1 0.1 0.4 -0.3 03/01/2006 16:30:00 1.3 0.6 2.6 0.4 1.3 0.6 2.6 0.4 1.4 0.6 2.6 0.4 161 8 165 165 -0.4 0.3 0.2 -0.8 03/01/2006 16:40:00 1.1 0.6 2.6 0.4 1.1 0.6 2.6 0.4 1.1 0.6 2.6 0.4 173 13 166 165 -0.4 0.1 -0.1 -0.8 03/01/2006 16:50:00 2.5 0.4 3.4 1.5 2.4 0.4 3.4 1.5 2.5 0.4 3.8 1.5 170 5 174 165 -1.3 0.2 -0.8 -1.7 03/01/2006 17:00:00 1.4 0.4 2.3 0.4 1.4 0.5 2.3 0.4 1.4 0.4 2.3 0.4 198 23 165 165 -1.7 0 -1.7 -1.9 03/01/2006 17:10:00 1.4 0.5 2.6 0.7 1.5 0.4 2.6 0.7 1.5 0.5 2.6 0.7 223 17 192 165 -1.8 0 -1.7 -1.9 03/01/2006 17:20:00 2.3 0.4 3 1.1 2.3 0.3 3 1.5 2.4 0.3 3 1.5 180 8 173 165 -2.1 0 -1.9 -2.4 03/01/2006 17:30:00 2.3 0.3 3 1.5 2.3 0.3 3 1.5 2.5 0.3 3.4 1.5 171 5 169 165 -2.3 0 -2.1 -2.6 03/01/2006 17:40:00 1.8 0.3 2.6 1.1 1.9 0.2 2.6 1.5 2 0.2 2.6 1.5 174 3 171 165 -2.4 0 -2.1 -2.6 03/01/2006 17:50:00 1.4 0.3 2.3 0.7 1.5 0.3 2.3 0.7 1.7 0.3 2.6 1.1 176 1 176 165 -2.5 0 -2.4 -2.6 03/01/2006 18:00:00 2 0.3 3 1.5 2.1 0.2 3 1.5 2.3 0.2 2.6 1.5 171 5 164 165 -2.5 0 -2.6 -2.8 03/01/2006 18:10:00 1.5 0.5 2.3 0.4 1.6 0.4 2.3 0.7 1.8 0.5 2.6 0.7 167 3 163 165 -2.6 0 -2.6 -2.8 03/01/2006 18:20:00 1.5 0.7 2.6 0.4 1.7 0.7 3 0.4 1.8 0.6 2.6 0.7 161 5 153 165 -2.8 0 -2.6 -2.8 03/01/2006 18:30:00 1.1 0.4 1.9 0.4 1.3 0.4 2.3 0.7 1.6 0.3 2.3 1.1 160 3 162 165 -2.8 0 -2.8 -3 03/01/2006 18:40:00 1.2 0.3 1.9 0.7 1.3 0.3 1.9 0.7 1.6 0.2 2.3 0.7 162 3 164 165 -2.9 0 -2.8 -3 03/01/2006 18:50:00 0.9 0.4 1.9 0.4 1 0.5 1.9 0.4 1.3 0.4 2.3 0.4 154 5 159 165 -3 0.1 -2.6 -3 03/01/2006 19:00:00 1.5 0.6 3 0.4 1.7 0.7 3 0.4 1.8 0.6 3 0.4 140 5 125 165 -3 0 -2.8 -3 03/01/2006 19:10:00 2.5 0.4 3.4 1.5 2.7 0.4 3.4 1.9 2.8 0.4 3.8 1.9 118 5 121 165 -3 0 -2.8 -3 03/01/2006 19:20:00 1.9 0.2 2.3 1.1 2.1 0.2 2.6 1.5 2.3 0.2 2.6 1.9 120 3 116 165 -3 0 -2.8 -3 03/01/2006 19:30:00 1.7 0.3 2.3 0.7 1.8 0.3 2.3 1.1 2 0.3 2.6 1.1 138 12 149 165 -3 0 -2.8 -3.3 03/01/2006 19:40:00 1.6 0.4 2.3 0.7 1.7 0.5 2.6 0.7 2.1 0.4 2.6 1.1 133 6 127 165 -3 0 -2.8 -3 03/01/2006 19:50:00 1.2 0.5 2.3 0.4 1.4 0.4 2.3 0.4 1.8 0.4 2.6 1.1 131 1 131 165 -3 0 -2.8 -3.3 03/01/2006 20:00:00 1.1 0.4 1.9 0.4 1.2 0.4 1.9 0.4 1.5 0.4 2.3 0.7 145 4 148 165 -2.9 0 -2.8 -3 03/01/2006 20:10:00 1.9 0.3 2.6 1.1 2 0.3 2.6 1.5 2.3 0.3 3 1.9 147 1 147 165 -2.8 0 -2.6 -2.8 03/01/2006 20:20:00 1.5 0.3 2.3 0.7 1.7 0.3 2.3 1.1 2 0.3 2.6 1.1 145 6 142 165 -2.8 0 -2.6 -2.8 03/01/2006 20:30:00 1.3 0.3 2.3 0.7 1.5 0.3 2.3 0.7 1.8 0.3 2.6 1.1 142 1 140 165 -2.9 0 -2.6 -3 03/01/2006 20:40:00 2.7 0.3 3.4 1.9 2.8 0.3 3.4 1.9 2.8 0.4 3.8 1.9 136 6 145 165 -2.7 0.1 -2.6 -3 03/01/2006 20:50:00 1.6 0.5 3 0.7 1.8 0.4 3 0.7 2.1 0.4 3 1.1 148 5 135 165 -2.5 0.1 -2.4 -2.8 03/01/2006 21:00:00 1.3 0.4 2.3 0.4 1.4 0.4 2.3 0.4 2 0.3 2.6 1.1 152 6 144 165 -2.5 0 -2.1 -2.6 03/01/2006 21:10:00 1.6 0.4 2.6 0.4 1.7 0.4 2.6 0.4 2.1 0.3 3 1.5 151 6 156 165 -2.5 0 -2.4 -2.6 03/01/2006 21:20:00 1.6 0.5 3 0.4 1.6 0.5 3 0.4 2.1 0.5 3 1.1 160 6 153 165 -2.4 0 -2.1 -2.6 03/01/2006 21:30:00 2.1 0.4 3 1.1 2.2 0.4 3 0.7 2.4 0.4 3 1.1 181 10 184 165 -2.3 0 -2.1 -2.6 03/01/2006 21:40:00 2.1 0.6 3 0.7 2.2 0.5 3 0.4 2.3 0.5 3.4 1.1 186 10 179 165 -2 0.1 -1.7 -2.1 03/01/2006 21:50:00 2.4 0.4 3.4 1.1 2.5 0.4 3.4 1.5 2.8 0.4 3.4 1.5 198 7 196 165 -2 0 -1.9 -2.1 03/01/2006 22:00:00 0.6 0.3 1.5 0.4 0.7 0.4 1.9 0.4 1.3 0.5 2.3 0.4 211 8 216 165 -2 0 -1.9 -2.1 03/01/2006 22:10:00 0.4 0.2 1.9 0.4 0.5 0.3 1.9 0.4 1.3 0.2 1.9 0.7 218 3 216 165 -2 0 -1.9 -2.1 03/01/2006 22:20:00 0.5 0.2 1.1 0.4 0.4 0.1 1.1 0.4 1.2 0.4 1.9 0.4 187 13 194 165 -2.1 0 -1.9 -2.1 03/01/2006 22:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0.2 1.1 0.4 177 0 165 165 -2.1 0 -2.1 -2.4 03/01/2006 22:40:00 0.4 0 0.7 0.4 0.4 0 0.4 0.4 0.8 0.3 1.5 0.4 236 43 266 165 -2.1 0 -2.1 -2.1 03/01/2006 22:50:00 0.6 0.3 1.5 0.4 0.6 0.3 1.5 0.4 0.8 0.3 1.5 0.4 287 8 289 165 -2.3 0 -2.1 -2.6 03/01/2006 23:00:00 1 0.6 2.3 0.4 0.9 0.7 2.3 0.4 1.3 0.8 2.6 0.4 232 39 200 165 -2.2 0 -1.9 -2.6 03/01/2006 23:10:00 0.9 0.5 2.3 0.4 1.2 0.5 2.3 0.4 1.7 0.7 2.6 0.4 182 6 199 165 -2 0 -1.9 -2.1 03/01/2006 23:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 176 9 165 165 -2.4 0.1 -1.9 -2.6 03/01/2006 23:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.7 0.4 165 0 165 165 -2.5 0 -2.4 -2.6 03/01/2006 23:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.7 0.3 1.5 0.4 107 76 165 165 -2.7 0 -2.6 -3 03/01/2006 23:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0.1 1.1 0.4 55 18 165 165 -2.8 0 -2.6 -3 03/02/2006 00:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0.1 1.1 0.4 104 0 165 165 -2.6 0.1 -2.6 -2.8 03/02/2006 00:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0.2 1.1 0.4 104 0 165 165 -2.5 0 -2.4 -2.6 03/02/2006 00:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0.1 0.7 0.4 104 0 165 165 -2.5 0 -2.4 -2.6 03/02/2006 00:30:00 0.8 0.4 1.5 0.4 0.9 0.5 1.5 0.4 1.2 0.5 1.9 0.4 117 12 126 165 -2.5 0 -2.6 -2.8 03/02/2006 00:40:00 0.5 0.2 1.1 0.4 0.7 0.3 1.1 0.4 1.2 0.4 1.9 0.4 136 0 136 165 -2.7 0 -2.6 -2.8 03/02/2006 00:50:00 0.4 0.2 1.1 0.4 0.6 0.3 1.5 0.4 1 0.4 1.5 0.4 127 11 136 165 -2.7 0 -2.6 -2.8 03/02/2006 01:00:00 0.5 0.2 1.1 0.4 0.4 0 0.7 0.4 0.7 0.2 1.1 0.4 156 27 176 165 -2.6 0.1 -2.6 -2.8 03/02/2006 01:10:00 0.8 0.3 1.5 0.4 0.6 0.4 1.5 0.4 1 0.3 1.5 0.4 184 6 187 165 -2.5 0 -2.4 -2.6 03/02/2006 01:20:00 1.2 0.7 3 0.4 1.4 0.7 3 0.4 1.6 0.7 2.6 0.4 174 7 162 165 -2.4 0 -2.1 -2.6 03/02/2006 01:30:00 2.2 0.8 3.8 0.7 2.4 0.7 3.8 0.7 2.4 0.5 3.4 1.1 168 7 172 165 -2.4 0 -2.1 -2.6 03/02/2006 01:40:00 2.5 0.4 3.4 1.1 2.6 0.4 3.4 1.5 2.7 0.4 3.4 1.9 162 14 163 165 -2.3 0.1 -2.1 -2.6 03/02/2006 01:50:00 3 0.4 3.8 1.5 3 0.4 3.8 1.9 3.3 0.3 4.2 2.3 150 4 151 165 -2.6 0 -2.6 -2.8 03/02/2006 02:00:00 2.9 0.4 3.8 1.9 3 0.4 3.8 1.9 3.2 0.3 4.2 2.3 153 6 166 165 -2.6 0 -2.6 -2.8 03/02/2006 02:10:00 3 0.3 3.8 2.3 3.1 0.3 3.8 2.3 3.4 0.3 4.2 2.6 149 6 154 165 -2.5 0 -2.6 -2.6 03/02/2006 02:20:00 3.2 0.4 3.8 1.9 3.2 0.4 3.8 1.9 3.3 0.4 4.2 1.9 154 5 153 165 -2.5 0 -2.4 -2.6 03/02/2006 02:30:00 2 0.5 3 0.7 2.2 0.5 3.4 1.1 2.6 0.5 3.8 1.5 150 8 137 165 -2.5 0 -2.1 -2.6 03/02/2006 02:40:00 2.8 0.4 3.4 1.5 2.8 0.3 3.8 1.9 3.1 0.3 3.8 2.6 157 6 150 165 -2.4 0 -2.1 -2.6 03/02/2006 02:50:00 3.5 0.8 5.7 1.9 3.5 0.8 5.3 2.3 3.6 0.6 5.3 2.6 164 9 182 165 -2.2 0 -2.1 -2.6 03/02/2006 03:00:00 5.8 0.6 7.2 4.2 5.6 0.5 6.8 3.8 5.5 0.6 7.2 4.2 172 5 181 165 -2.1 0 -1.9 -2.4 03/02/2006 03:10:00 6.4 0.9 8.8 4.6 6.2 0.8 8.4 4.6 6.4 0.7 7.6 4.6 171 10 170 165 -1.7 0.3 -1.2 -2.1 03/02/2006 03:20:00 6.8 0.6 8.4 5.3 6.5 0.5 8 5.3 6.8 0.6 8 5.3 169 6 165 165 -1.4 0 -1.2 -1.4 03/02/2006 03:30:00 5.8 0.5 6.5 4.6 5.6 0.4 6.5 4.6 5.7 0.5 6.5 4.6 170 3 171 165 -1.2 0 -1 -1.4 03/02/2006 03:40:00 5.1 0.4 6.1 4.2 5 0.3 5.7 4.2 5.2 0.4 6.1 4.6 175 3 170 165 -0.9 0.1 -0.8 -1.2 03/02/2006 03:50:00 4.3 0.4 4.9 3.4 4.2 0.4 4.9 3.4 4.5 0.5 5.7 3.4 184 3 180 165 -0.9 0 -0.8 -1 03/02/2006 04:00:00 4.2 0.4 4.9 3.4 4.2 0.4 4.9 3.4 4.4 0.4 5.3 3.4 186 3 184 165 -0.9 0 -0.8 -1 03/02/2006 04:10:00 3.2 0.2 3.8 2.6 3.3 0.2 3.8 2.6 3.7 0.2 4.2 3 187 7 183 165 -0.8 0 -0.5 -1 03/02/2006 04:20:00 3.1 0.4 4.6 2.3 3.1 0.4 4.2 2.3 3.5 0.4 4.2 2.6 185 6 199 165 -0.6 0 -0.5 -0.8 03/02/2006 04:30:00 3.1 0.6 5.7 1.9 3.1 0.6 5.3 1.9 3.4 0.4 4.9 2.3 177 10 196 165 -0.5 0 -0.3 -0.8 03/02/2006 04:40:00 3.4 0.7 5.3 1.1 3.4 0.6 5.3 1.5 3.7 0.5 5.3 2.6 157 8 163 165 -0.8 0.1 -0.5 -0.8 03/02/2006 04:50:00 3.8 0.7 5.7 1.5 3.8 0.7 5.7 1.9 4 0.6 6.1 1.9 168 10 162 165 -0.6 0 -0.5 -1 03/02/2006 05:00:00 2.6 0.7 4.2 0.7 2.7 0.6 4.2 1.1 3.1 0.5 4.9 1.9 174 10 186 165 -0.3 0.1 -0.1 -0.5 03/02/2006 05:10:00 2.9 1.6 7.2 0.4 3.1 1.5 7.2 0.4 3.3 1.3 6.5 0.4 199 22 185 165 -0.3 0 -0.1 -0.5 03/02/2006 05:20:00 3.6 1.6 8 0.7 3.7 1.5 8 1.1 3.8 1.4 8 1.5 192 13 205 165 -0.2 0 -0.1 -0.5 03/02/2006 05:30:00 3.6 1 6.5 1.1 3.7 0.9 6.5 1.1 4 0.8 5.7 1.9 187 11 201 165 -0.3 0 -0.1 -0.5 03/02/2006 05:40:00 1.2 0.9 4.2 0.4 1.4 0.9 4.6 0.4 1.9 0.8 4.2 0.4 182 22 181 165 -0.3 0 -0.1 -0.5 03/02/2006 05:50:00 3 1.9 6.1 0.4 3.1 1.8 6.1 0.4 3.3 1.4 6.1 1.1 185 17 216 165 -0.5 0.1 -0.3 -0.8 03/02/2006 06:00:00 3.3 0.7 6.1 1.5 3.4 0.7 6.1 1.5 3.5 0.6 6.1 2.3 175 15 231 165 -0.5 0 -0.3 -0.8 03/02/2006 06:10:00 1.9 0.6 3.4 0.4 2 0.6 3.4 0.4 2.5 0.5 4.2 1.1 147 18 176 165 -0.6 0 -0.5 -0.8 03/02/2006 06:20:00 2.5 1.2 5.3 0.4 2.5 1.2 4.9 0.4 2.9 1 5.3 1.1 159 12 162 165 -0.5 0 -0.3 -0.5 03/02/2006 06:30:00 2.7 0.7 4.6 0.4 2.7 0.6 4.6 0.7 3.2 0.6 4.6 1.1 160 26 159 165 -0.2 0 0.2 -0.5 03/02/2006 06:40:00 2.1 0.8 4.2 0.4 2.2 0.8 4.2 0.4 2.7 0.7 4.6 1.1 157 15 145 165 -0.1 0 0.2 -0.1 03/02/2006 06:50:00 3.9 1 6.1 1.5 3.9 0.9 5.7 1.9 4.2 0.9 6.5 2.6 154 13 170 165 0 0 0.2 -0.1 03/02/2006 07:00:00 3.2 1.2 5.3 0.4 3.3 1.1 5.3 0.4 3.4 1 4.9 1.1 167 11 180 165 0.1 0 0.2 -0.1 03/02/2006 07:10:00 5.2 0.5 6.8 3.8 5.2 0.5 6.8 4.2 5.3 0.6 6.8 3.8 173 6 173 165 0.1 0 0.2 -0.1 03/02/2006 07:20:00 6.1 0.6 8.4 4.6 6 0.6 8.4 4.6 6.2 0.6 8 4.6 171 5 161 165 0.1 0 0.2 -0.1 03/02/2006 07:30:00 7 1 9.5 5.3 6.9 0.9 9.1 5.3 7.3 1 9.1 5.3 170 6 183 165 0.3 0 0.7 0.2 03/02/2006 07:40:00 7.6 0.9 9.9 6.1 7.5 0.9 9.9 6.1 7.8 0.9 10.3 6.5 167 13 166 165 0.4 0.1 0.7 0.2 03/02/2006 07:50:00 10.4 0.5 11.8 9.1 10 0.4 11.1 8.8 10.6 0.5 11.8 9.1 167 7 185 165 0.5 0 0.7 0.2 03/02/2006 08:00:00 10.9 0.8 12.6 9.1 10.5 0.8 11.8 8.8 11.1 0.8 13 9.1 170 6 163 165 0.6 0 0.9 0.4 03/02/2006 08:10:00 12.2 0.7 14.1 9.5 11.8 0.6 13.7 9.9 12.5 0.7 14.1 10.3 169 11 273 165 0.7 0 0.9 0.4 03/02/2006 08:20:00 13.2 0.7 14.9 11.5 12.7 0.7 14.1 11.1 13.5 0.7 15.3 11.5 168 4 169 165 0.5 0 0.9 0.2 03/02/2006 08:30:00 11.7 1 13.3 8.8 11.2 1 13 8.8 12 1.1 13.7 8.8 171 9 169 165 0.4 0 0.7 0.2 03/02/2006 08:40:00 9.9 0.8 12.2 7.6 9.6 0.7 11.8 7.6 10.1 0.8 12.2 8 175 6 131 165 0.3 0 0.7 0.2 03/02/2006 08:50:00 11.6 1 13.7 9.5 11.2 1 13.3 9.1 11.8 1.1 14.5 9.5 168 8 165 165 0.4 0 0.7 0.2 03/02/2006 09:00:00 9.1 0.6 10.3 7.6 8.9 0.5 10.3 7.6 9.3 0.7 11.1 7.2 167 5 165 165 0.5 0 0.7 0.2 03/02/2006 09:10:00 9.5 0.8 12.2 7.6 9.3 0.8 11.8 7.6 9.5 0.9 12.2 6.8 166 11 164 165 0.5 0 0.7 0.2 03/02/2006 09:20:00 12.1 1 14.1 9.9 12 1 14.5 9.9 12.3 1.1 15.6 9.9 165 5 150 165 0.5 0 0.7 0.4 03/02/2006 09:30:00 14 1.5 17.9 11.5 13.7 1.3 17.6 11.1 14.2 1.3 17.9 10.7 167 13 165 165 0.7 0 0.9 0.7 03/02/2006 09:40:00 14.4 1.1 16.8 12.2 14.1 1 16.4 11.5 14.6 1.2 17.9 11.5 171 12 172 165 0.8 0 1.1 0.7 03/02/2006 09:50:00 14 1 16.4 11.1 13.6 0.9 15.6 11.1 14.1 1 16.4 11.5 169 9 172 165 0.9 0 1.1 0.9 03/02/2006 10:00:00 13.2 1.3 16.1 10.3 13 1.3 15.6 10.3 13.6 1.5 16.8 9.9 164 16 162 165 0.9 0.1 1.1 0.7 03/02/2006 10:10:00 14 1 17.2 11.8 13.6 0.9 16.8 11.5 14.2 1 16.8 11.8 169 11 164 165 0.8 0 0.9 0.7 03/02/2006 10:20:00 14.8 1 17.2 12.6 14.4 1 16.8 12.2 15.1 1 17.2 12.6 168 9 165 165 0.7 0 0.9 0.7 03/02/2006 10:30:00 13.2 1.5 16.8 10.7 13.1 1.5 16.8 10.3 13.5 1.7 17.9 10.7 167 17 164 165 0.7 0.1 0.9 0.7 03/02/2006 10:40:00 12 1.2 15.3 9.5 11.8 1.1 14.5 8.8 12.2 1.1 15.3 9.5 168 17 180 165 0.7 0 0.9 0.7 03/02/2006 10:50:00 13.6 1 16.8 11.1 13.3 0.9 15.6 11.1 13.9 1 16.1 11.5 168 8 167 165 0.5 0 0.7 0.4 03/02/2006 11:00:00 13 0.8 14.9 10.7 12.8 0.8 14.5 10.3 13.1 0.8 14.9 10.7 167 6 164 165 0.6 0 0.9 0.7 03/02/2006 11:10:00 11.3 1 13.3 9.1 11.4 1 13.7 9.1 11.5 1.1 14.1 9.1 163 9 165 165 0.7 0 0.9 0.7 03/02/2006 11:20:00 12.2 0.6 13.7 10.3 12.2 0.5 13.7 10.3 12.6 0.6 13.7 10.7 168 17 163 165 0.8 0 0.9 0.7 03/02/2006 11:30:00 12.1 0.8 13.7 9.9 12.1 0.8 13.7 9.9 12.3 0.9 14.1 9.9 165 6 164 165 0.8 0 0.9 0.7 03/02/2006 11:40:00 9.6 1 11.5 7.2 9.7 1 11.5 7.2 9.8 1.1 11.8 7.6 165 9 170 165 0.8 0 0.9 0.7 03/02/2006 11:50:00 7.2 0.6 8.8 6.1 7.2 0.6 8.8 5.7 7.4 0.6 9.1 6.1 160 4 162 165 0.8 0 0.9 0.7 03/02/2006 12:00:00 6.9 0.5 8 5.7 6.9 0.5 8 5.7 7.2 0.5 8.4 5.3 155 2 154 165 0.8 0 0.9 0.7 03/02/2006 12:10:00 6.6 0.5 7.6 5.3 6.7 0.4 7.6 5.3 6.8 0.5 8 5.3 154 3 155 165 0.8 0 0.9 0.9 03/02/2006 12:20:00 7.1 0.5 8.8 5.7 7.2 0.5 8.4 5.7 7.3 0.5 8.8 5.7 156 3 162 165 0.8 0 0.9 0.7 03/02/2006 12:30:00 7.3 0.5 8.8 5.7 7.3 0.5 8.4 5.7 7.5 0.5 9.1 6.5 161 8 162 165 0.9 0 1.1 0.9 03/02/2006 12:40:00 8 0.6 9.5 6.5 7.9 0.5 9.1 6.5 8.2 0.5 9.5 6.8 159 4 153 165 0.8 0 0.9 0.9 03/02/2006 12:50:00 7.6 0.4 8.4 6.5 7.6 0.3 8.4 6.5 7.9 0.4 8.8 6.8 161 10 162 165 0.8 0 0.9 0.9 03/02/2006 13:00:00 7.4 0.4 8.8 6.5 7.4 0.4 8.8 6.5 7.6 0.3 8.8 6.8 166 9 164 165 0.8 0 0.9 0.9 03/02/2006 13:10:00 7.9 0.5 9.5 6.1 7.9 0.5 9.1 6.1 8 0.5 9.1 6.1 166 5 176 165 0.8 0 1.1 0.9 03/02/2006 13:20:00 7.2 0.6 9.1 5.7 7.2 0.5 8.8 5.7 7.3 0.5 8.4 6.1 163 12 163 165 0.9 0 1.1 0.9 03/02/2006 13:30:00 5.5 0.5 6.8 4.6 5.6 0.5 6.8 4.6 5.8 0.5 6.8 4.6 160 6 161 165 0.9 0 1.1 0.9 03/02/2006 13:40:00 5.3 0.3 6.1 4.6 5.4 0.3 6.5 4.9 5.6 0.3 6.8 4.9 153 4 157 165 1 0 1.4 0.9 03/02/2006 13:50:00 5.6 0.4 6.8 4.6 5.8 0.4 6.8 4.9 6 0.3 6.8 5.3 147 0 147 165 1.1 0 1.4 0.9 03/02/2006 14:00:00 6.6 0.3 8 5.7 6.8 0.3 7.6 5.7 7 0.3 7.6 6.1 147 0 147 165 1.1 0 1.4 0.9 03/02/2006 14:10:00 7.2 0.5 8.8 6.1 7.3 0.4 8.8 6.5 7.4 0.5 8.8 6.1 147 0 147 165 1.2 0 1.4 1.1 03/02/2006 14:20:00 8.5 0.9 9.9 6.5 8.5 0.8 10.3 6.5 8.5 0.9 10.3 6.1 147 0 147 165 1.3 0 1.4 1.1 03/02/2006 14:30:00 9.4 0.4 10.7 8 9.4 0.4 10.3 8 9.5 0.5 10.7 8 147 0 147 165 1.3 0 1.4 1.1 03/02/2006 14:40:00 9.2 0.4 10.3 7.6 9.3 0.4 9.9 8 9.5 0.5 10.7 7.2 147 0 147 165 1.2 0 1.4 1.1 03/02/2006 14:50:00 8.8 0.6 9.9 6.5 8.8 0.6 9.9 6.8 8.7 0.8 10.3 6.5 147 0 147 165 1.2 0 1.4 1.1 03/02/2006 15:00:00 9.6 0.6 10.7 7.6 9.5 0.7 10.7 7.2 9.5 0.8 11.1 7.2 147 0 147 165 1.2 0 1.4 1.1 03/02/2006 15:10:00 9.3 0.4 10.3 8 9 0.4 9.9 7.6 9 0.5 10.3 6.8 147 0 147 165 1.1 0 1.4 0.9 03/02/2006 15:20:00 9.7 0.4 10.3 8.4 9.5 0.4 10.3 8 9.7 0.5 10.7 8 147 0 147 165 1.1 0 1.4 0.9 03/02/2006 15:30:00 9.6 0.4 10.3 8.4 9.3 0.4 9.9 7.6 9.5 0.5 10.3 8 147 0 147 165 1.1 0 1.4 1.1 03/02/2006 15:40:00 9 0.3 9.9 8 8.7 0.3 9.5 7.6 9.1 0.4 10.3 8 147 0 147 165 1.1 0 1.4 0.9 03/02/2006 15:50:00 8.6 0.3 9.5 7.2 8.4 0.3 9.1 7.2 8.7 0.4 9.1 7.2 147 0 147 165 1 0 1.1 0.9 03/02/2006 16:00:00 8 0.4 9.1 6.8 8 0.4 8.8 6.8 8.1 0.5 9.1 6.5 147 0 147 165 1 0 1.1 0.9 03/02/2006 16:10:00 7.9 0.4 8.8 6.8 8 0.3 8.8 6.8 8.1 0.4 8.8 6.8 147 0 147 165 1 0 1.1 0.9 03/02/2006 16:20:00 8.2 0.4 8.8 7.2 8.4 0.3 9.1 7.2 8.4 0.4 9.5 7.2 147 0 147 165 1 0 1.1 0.9 03/02/2006 16:30:00 8 0.6 9.1 6.1 8.3 0.6 9.5 6.5 8.3 0.6 9.5 5.7 147 0 147 165 1 0 1.4 0.9 03/02/2006 16:40:00 7.7 0.5 9.1 6.5 8.1 0.5 9.1 6.8 7.8 0.6 9.1 6.1 147 0 147 165 1 0 1.1 0.9 03/02/2006 16:50:00 7.7 0.4 8.8 6.5 8.2 0.3 9.1 7.2 7.9 0.4 9.1 6.5 147 0 147 165 1 0 1.1 0.9 03/02/2006 17:00:00 7.4 0.5 8.4 6.1 7.9 0.5 8.8 6.1 7.7 0.5 8.8 6.5 147 0 147 165 1 0 1.1 0.9 03/02/2006 17:10:00 6.8 0.4 8 6.1 7.5 0.4 8.4 6.5 7.3 0.5 8.4 5.7 147 0 147 165 1 0 1.4 0.9 03/02/2006 17:20:00 7.2 0.6 8.4 5.7 7.6 0.5 8.8 6.1 7.8 0.5 8.8 5.7 147 0 147 165 0.9 0 1.1 0.9 03/02/2006 17:30:00 6.6 0.4 8 5.7 7.3 0.4 8.4 6.1 7.5 0.4 8.4 6.1 147 0 147 165 1.1 0 1.4 0.9 03/02/2006 17:40:00 6.9 0.6 8.4 5.3 7.6 0.5 9.1 6.1 7.6 0.5 9.1 6.1 147 0 147 165 1.1 0 1.4 0.9 03/02/2006 17:50:00 6.6 0.8 8.4 4.6 7.3 0.8 9.1 5.3 7.5 0.7 9.1 5.3 147 0 147 165 1.1 0 1.4 0.9 03/02/2006 18:00:00 6.3 0.6 7.6 4.9 7.1 0.6 8.4 5.3 7.2 0.6 8.4 5.7 147 0 147 165 1.1 0 1.4 0.9 03/02/2006 18:10:00 6.5 0.5 7.6 4.9 7.3 0.5 8 5.7 7.5 0.5 8.8 6.5 147 0 147 165 1.1 0 1.4 0.9 03/02/2006 18:20:00 6.5 0.7 8 4.6 7.2 0.7 8.8 4.9 7.5 0.7 9.1 5.7 147 0 147 165 1.1 0 1.4 0.9 03/02/2006 18:30:00 7.3 0.6 8.8 5.3 7.8 0.6 9.1 5.7 8.1 0.6 9.5 6.5 147 0 147 165 1.1 0 1.4 0.9 03/02/2006 18:40:00 7.3 0.5 8.4 6.1 7.8 0.4 8.8 6.5 8.3 0.5 9.1 6.8 147 0 147 165 1.1 0 1.4 0.9 03/02/2006 18:50:00 7.1 0.6 8.4 5.3 7.7 0.6 8.8 5.7 8 0.6 9.1 5.7 147 0 147 165 1.1 0 1.4 1.1 03/02/2006 19:00:00 7.4 0.7 8.4 5.3 7.9 0.5 8.8 6.1 8.4 0.8 9.5 5.7 147 0 147 165 1.1 0 1.4 1.1 03/02/2006 19:10:00 7.3 0.8 8.4 5.3 7.8 0.6 8.8 6.1 8.2 0.6 9.5 6.5 147 0 147 165 1.2 0 1.4 1.1 03/02/2006 19:20:00 7.6 0.7 8.8 5.3 8 0.6 9.1 6.5 8.4 0.7 9.9 6.8 147 0 147 165 1.2 0 1.4 1.1 03/02/2006 19:30:00 8 0.7 9.5 5.7 8.2 0.6 9.5 6.5 8.7 0.7 10.3 7.2 147 0 147 165 1.2 0 1.4 1.1 03/02/2006 19:40:00 7.9 0.5 9.1 6.1 8.1 0.5 9.1 6.8 8.6 0.6 9.9 6.8 147 0 147 165 1.2 0 1.4 1.1 03/02/2006 19:50:00 7.6 0.6 8.8 5.7 7.9 0.6 9.1 6.5 8.2 0.6 9.5 6.5 147 0 147 165 1.2 0 1.4 1.1 03/02/2006 20:00:00 7.4 0.8 9.1 4.9 7.7 0.8 9.1 5.3 8 0.8 9.9 6.1 147 0 147 165 1.2 0 1.4 1.1 03/02/2006 20:10:00 8.2 0.6 9.5 6.1 8.4 0.6 9.5 6.1 8.7 0.7 10.3 6.8 147 0 147 165 1.2 0 1.4 1.1 03/02/2006 20:20:00 8.1 0.7 9.5 5.7 7.8 0.5 9.1 6.1 8.1 0.6 9.9 6.5 147 0 147 165 1.2 0 1.4 1.1 03/02/2006 20:30:00 8.8 0.5 9.9 7.2 8.1 0.5 9.5 6.5 8.4 0.6 10.3 7.2 147 0 147 165 1.2 0 1.4 1.1 03/02/2006 20:40:00 8.5 0.7 10.7 6.8 7.8 0.8 10.3 5.7 8.3 0.8 10.7 6.8 147 0 147 165 1.2 0 1.4 1.1 03/02/2006 20:50:00 8.6 0.5 9.9 7.2 7.8 0.8 9.5 5.7 8.3 0.8 10.3 6.1 147 0 147 165 1.2 0 1.4 0.9 03/02/2006 21:00:00 8.4 0.4 9.5 7.2 7.6 0.5 8.4 6.1 8 0.5 9.5 6.5 147 0 147 165 1.2 0 1.4 1.1 03/02/2006 21:10:00 8.2 0.5 9.9 7.2 7.4 0.6 9.1 5.7 7.8 0.6 9.9 6.5 147 0 147 165 1.2 0 1.4 1.1 03/02/2006 21:20:00 7.8 0.4 9.1 6.5 6.8 0.5 8.4 5.3 7.4 0.5 8.8 5.7 147 0 147 165 1.1 0 1.4 1.1 03/02/2006 21:30:00 7.5 0.5 9.1 6.1 6.4 0.6 8 4.9 7 0.6 8.4 4.9 147 0 147 165 1.1 0 1.4 0.9 03/02/2006 21:40:00 7.7 0.6 9.1 6.5 6.6 0.6 8.4 5.3 7.3 0.5 8.4 6.1 147 0 147 165 1.1 0 1.4 1.1 03/02/2006 21:50:00 7.2 0.5 8.4 6.1 6.1 0.5 7.6 4.9 7 0.5 8.8 5.3 147 0 147 165 1.2 0 1.4 1.1 03/02/2006 22:00:00 7.1 0.6 8.4 5.3 5.9 0.7 7.6 4.2 6.8 0.7 8.4 4.6 147 0 147 165 1.1 0 1.4 0.9 03/02/2006 22:10:00 6.5 0.5 7.6 5.7 5.2 0.5 6.1 4.2 6.2 0.6 7.6 4.6 147 0 147 165 1.1 0 1.4 0.9 03/02/2006 22:20:00 6.6 0.4 7.6 5.3 5.1 0.4 6.1 3.8 6.3 0.5 7.6 4.6 147 0 147 165 1.1 0 1.4 0.9 03/02/2006 22:30:00 6.7 0.5 7.6 5.3 5.1 0.4 5.7 4.2 6.3 0.5 7.6 4.9 147 0 147 165 1.1 0 1.4 0.9 03/02/2006 22:40:00 5.8 0.7 7.6 4.6 3.6 0.8 6.1 2.3 5.3 0.9 8 3.4 147 0 147 165 1.1 0 1.4 0.9 03/02/2006 22:50:00 6.1 0.6 7.2 4.2 3.8 0.5 4.9 2.3 5.6 0.6 6.8 3.8 147 0 147 165 1.1 0 1.4 0.9 03/02/2006 23:00:00 6 0.5 7.6 4.6 3.7 0.6 5.3 2.3 5.7 0.6 7.6 4.6 147 0 147 165 1.2 0 1.4 1.1 03/02/2006 23:10:00 5.6 0.5 6.8 4.2 3.1 0.5 4.2 1.9 4.8 0.5 6.1 3.8 147 0 147 165 1.2 0 1.4 1.1 03/02/2006 23:20:00 5.3 0.5 6.5 4.2 2.8 0.6 3.8 0.7 4.7 0.6 6.1 3.4 147 0 147 165 1.1 0 1.4 0.9 03/02/2006 23:30:00 5.5 0.5 6.8 4.2 3 0.5 4.2 1.5 4.8 0.6 6.5 3.4 147 0 147 165 1.1 0 1.4 0.9 03/02/2006 23:40:00 5.2 0.6 6.5 4.2 2.8 0.7 4.2 1.1 4.7 0.8 6.5 3 147 0 147 165 1.2 0 1.4 1.1 03/02/2006 23:50:00 5.6 0.7 6.8 3.8 3.1 0.7 4.6 1.1 5.1 0.9 6.8 3 147 0 147 165 1.2 0 1.4 0.9 03/03/2006 00:00:00 5.3 0.5 6.8 4.2 3.3 0.5 4.6 1.9 4.7 0.8 6.5 2.6 147 0 147 165 1.4 0 1.4 1.4 03/03/2006 00:10:00 5.3 0.4 6.5 4.2 3.3 0.5 4.6 2.3 4.6 0.6 5.7 3 147 0 147 165 1.4 0 1.6 1.4 03/03/2006 00:20:00 4.7 0.7 6.5 2.6 3.3 0.8 4.9 0.7 4.2 0.8 6.1 1.9 147 0 147 165 1.4 0 1.6 1.4 03/03/2006 00:30:00 4.9 0.6 6.1 3.4 3.5 0.7 4.6 1.5 4.5 0.9 6.1 2.3 147 0 147 165 1.4 0 1.6 1.4 03/03/2006 00:40:00 4.7 0.5 6.1 3.4 3.3 0.5 4.6 2.3 4.3 0.6 5.7 2.6 147 0 147 165 1.4 0 1.6 1.4 03/03/2006 00:50:00 4.9 0.5 6.1 3.4 3.3 0.5 4.6 1.5 4.6 0.5 5.3 3.4 147 0 147 165 1.5 0 1.6 1.4 03/03/2006 01:00:00 4.4 0.7 6.1 3 2.9 0.9 4.6 1.1 4.5 0.8 6.1 3 147 0 147 165 1.4 0 1.6 1.4 03/03/2006 01:10:00 3.5 0.5 4.9 2.3 0.8 0.9 3.4 0.4 3.9 0.5 5.3 3 147 0 147 165 1.4 0 1.6 1.4 03/03/2006 01:20:00 3.4 0.5 4.6 2.3 0.4 0 0.4 0.4 3.9 0.5 5.3 2.6 147 0 147 165 1.4 0 1.6 1.4 03/03/2006 01:30:00 2.9 0.5 4.2 1.9 0.4 0 0.4 0.4 3.3 0.5 4.6 2.3 147 0 147 165 1.4 0 1.6 1.4 03/03/2006 01:40:00 2.3 1.1 3.8 0.4 0.4 0 0.4 0.4 3.2 0.7 4.6 1.9 147 0 147 165 1.4 0 1.6 1.4 03/03/2006 01:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 2.2 0.9 4.2 0.7 147 0 165 165 1.3 0 1.4 1.4 03/03/2006 02:00:00 1.6 0.9 4.2 0.4 0.4 0 0.4 0.4 3.2 0.4 4.2 2.3 147 0 147 165 1.4 0 1.4 1.4 03/03/2006 02:10:00 2.7 0.6 3.8 0.7 0.4 0 0.4 0.4 3.6 0.5 4.9 2.3 147 0 147 165 1.4 0 1.4 1.4 03/03/2006 02:20:00 1 0.8 3 0.4 0.4 0 0.4 0.4 2.5 0.5 3.8 1.9 147 0 147 165 1.2 0 1.4 1.1 03/03/2006 02:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 2.3 0.5 3.4 1.5 147 0 165 165 1.2 0 1.4 1.1 03/03/2006 02:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 2.5 0.4 3.4 1.5 147 0 165 165 1.4 0 1.4 1.4 03/03/2006 02:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 3.4 0.5 4.6 2.3 147 0 165 165 1.4 0 1.6 1.4 03/03/2006 03:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 3.8 0.6 5.3 2.6 147 0 165 165 1.4 0 1.6 1.4 03/03/2006 03:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 2.8 0.6 3.8 1.5 147 0 165 165 1.3 0 1.4 1.4 03/03/2006 03:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 2 0.3 2.6 1.5 147 0 165 165 1.2 0 1.4 1.1 03/03/2006 03:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 2.3 0.8 3.8 1.1 147 0 165 165 1.2 0 1.4 1.1 03/03/2006 03:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 2.6 0.5 4.2 1.5 147 0 165 165 1.2 0 1.4 1.1 03/03/2006 03:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 3.8 0.6 4.9 2.6 147 0 165 165 1 0 1.4 0.9 03/03/2006 04:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 3.8 0.6 4.9 2.3 147 0 165 165 1 0 1.1 0.9 03/03/2006 04:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 3.7 0.7 4.6 1.5 147 0 165 165 1.1 0 1.4 0.9 03/03/2006 04:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 2.4 0.4 3.4 1.5 147 0 165 165 1.1 0 1.4 0.9 03/03/2006 04:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 2.2 0.4 3.4 1.5 147 0 165 165 1.1 0 1.4 0.9 03/03/2006 04:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 2.2 0.3 3 1.9 147 0 165 165 1.2 0 1.4 1.1 03/03/2006 04:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 2.9 0.5 3.8 1.9 147 0 165 165 1.2 0 1.4 1.4 03/03/2006 05:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 2.4 0.2 2.6 1.9 147 0 165 165 1.3 0 1.4 1.4 03/03/2006 05:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 2.6 0.3 3.4 1.9 147 0 165 165 1.4 0 1.4 1.4 03/03/2006 05:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 2.7 0.4 3.8 1.9 147 0 165 165 1.3 0 1.4 1.4 03/03/2006 05:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 3.1 0.2 3.4 2.6 147 0 165 165 1.2 0 1.4 1.1 03/03/2006 05:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 3 0.3 3.8 2.3 147 0 165 165 1.2 0 1.4 1.1 03/03/2006 05:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 2.1 0.4 3 1.5 147 0 165 165 1.2 0 1.4 1.1 03/03/2006 06:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 2.3 0.2 3 1.9 147 0 165 165 1.2 0 1.4 1.1 03/03/2006 06:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 1.8 0.3 2.6 1.1 147 0 165 165 1.2 0 1.4 1.1 03/03/2006 06:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 1.9 0.2 2.3 1.5 147 0 165 165 1.2 0 1.4 1.1 03/03/2006 06:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 1.4 0.3 2.3 0.7 147 0 165 165 1.2 0 1.4 1.1 03/03/2006 06:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 1.1 0.2 1.5 0.7 147 0 165 165 1.2 0 1.4 1.4 03/03/2006 06:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.9 0.3 1.5 0.4 147 0 165 165 1.2 0 1.4 1.4 03/03/2006 07:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0.2 1.1 0.4 147 0 165 165 1.2 0 1.4 1.1 03/03/2006 07:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.8 0.3 1.9 0.4 147 0 165 165 1 0 1.4 0.9 03/03/2006 07:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 1.7 0.3 2.6 0.7 147 0 165 165 1.1 0 1.4 0.9 03/03/2006 07:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 2 0.4 3 0.7 147 0 165 165 1.2 0 1.4 1.4 03/03/2006 07:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 1.8 0.6 3 0.7 147 0 165 165 1.4 0 1.4 1.4 03/03/2006 07:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 2.7 0.4 3.8 1.1 147 0 165 165 1.4 0 1.4 1.4 03/03/2006 08:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 1.8 0.5 3 1.1 147 0 165 165 1.4 0 1.6 1.4 03/03/2006 08:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 1.6 0.3 2.3 0.7 147 0 165 165 1.4 0 1.6 1.4 03/03/2006 08:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 1.9 0.3 2.6 0.7 147 0 165 165 1.4 0 1.6 1.4 03/03/2006 08:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 1.8 0.2 2.6 1.1 147 0 165 165 1.4 0 1.6 1.4 03/03/2006 08:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 1.5 0.2 1.9 0.7 147 0 165 165 1.4 0 1.6 1.4 03/03/2006 08:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 1.1 0.3 1.9 0.7 147 0 165 165 1.4 0 1.6 1.4 03/03/2006 09:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.7 0.3 1.5 0.4 147 0 165 165 1.5 0 1.6 1.4 03/03/2006 09:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 147 0 165 165 1.4 0 1.6 1.4 03/03/2006 09:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.9 0.6 2.3 0.4 147 0 165 165 1.4 0 1.6 1.4 03/03/2006 09:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 1.5 0.4 2.3 0.7 147 0 165 165 1.4 0 1.6 1.4 03/03/2006 09:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 1.6 0.2 2.3 1.1 147 0 165 165 1.4 0 1.4 1.4 03/03/2006 09:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 2.3 0.6 3.4 1.1 147 0 165 165 1.4 0 1.6 1.4 03/03/2006 10:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 2.3 0.5 3.4 1.5 147 0 165 165 1.4 0 1.6 1.4 03/03/2006 10:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 2.4 0.4 3.4 1.9 147 0 165 165 1.4 0 1.6 1.4 03/03/2006 10:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 2.5 0.3 3.4 1.5 147 0 165 165 1.4 0 1.6 1.4 03/03/2006 10:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 1.3 0.7 3 0.4 147 0 165 165 1.4 0 1.6 1.4 03/03/2006 10:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 2.8 1.1 4.9 0.4 147 0 165 165 1.4 0 1.4 1.4 03/03/2006 10:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 2.6 0.4 3.8 1.9 147 0 165 165 1.4 0 1.4 1.4 03/03/2006 11:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 3.6 0.4 4.2 2.6 147 0 165 165 1.4 0 1.4 1.4 03/03/2006 11:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 3.7 0.5 5.3 2.3 147 0 165 165 1.4 0 1.6 1.4 03/03/2006 11:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 2.9 0.6 4.6 1.5 147 0 165 165 1.4 0 1.6 1.4 03/03/2006 11:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 4.2 0.5 5.3 3 147 0 165 165 1.4 0 1.6 1.4 03/03/2006 11:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 3.8 0.4 4.9 3 147 0 165 165 1.5 0 1.6 1.4 03/03/2006 11:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 3.8 0.3 4.6 3 147 0 165 165 1.6 0 1.6 1.6 03/03/2006 12:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 3.4 0.4 4.6 2.3 138 17 165 165 1.7 0 1.8 1.6 03/03/2006 12:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 3.6 0.7 4.9 2.3 105 3 165 165 1.7 0 1.8 1.6 03/03/2006 12:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 2.8 0.6 4.2 1.9 112 2 165 165 1.7 0 1.8 1.6 03/03/2006 12:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 2.4 0.5 3.4 1.5 116 3 165 165 1.7 0 1.8 1.6 03/03/2006 12:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 2.7 0.5 3.8 1.1 109 5 165 165 1.7 0 1.8 1.6 03/03/2006 12:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 2.6 0.4 3.4 1.9 114 7 165 165 1.7 0 1.8 1.6 03/03/2006 13:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 2.1 0.3 3 1.1 111 3 165 165 1.7 0 1.8 1.6 03/03/2006 13:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 1.4 0.6 3 0.4 112 9 165 165 1.7 0 1.8 1.6 03/03/2006 13:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 2.8 0.3 3.4 1.9 108 5 165 165 1.7 0 1.8 1.6 03/03/2006 13:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 2.4 0.4 3.4 1.1 111 6 165 165 1.7 0 1.8 1.6 03/03/2006 13:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 2.4 0.5 3 1.1 107 1 165 165 1.7 0 1.8 1.6 03/03/2006 13:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 1.7 0.4 2.6 0.7 106 1 165 165 1.8 0 1.8 1.6 03/03/2006 14:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 1 0.2 1.9 0.4 101 7 165 165 1.9 0 1.8 1.8 03/03/2006 14:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.7 0.2 1.1 0.4 104 5 165 165 1.9 0 1.8 1.8 03/03/2006 14:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.9 0.3 1.5 0.4 103 5 165 165 1.9 0 1.8 1.8 03/03/2006 14:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.8 0.2 1.5 0.4 100 7 165 165 1.9 0 1.8 1.8 03/03/2006 14:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 1 0.3 1.9 0.4 108 6 165 165 1.9 0 1.8 1.8 03/03/2006 14:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.5 0.2 1.1 0.4 115 6 165 165 2 0 2.1 1.8 03/03/2006 15:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.5 0.4 1.5 0.4 124 6 165 165 2 0 2.3 1.8 03/03/2006 15:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 1.5 0.4 2.3 0.7 113 5 165 165 1.8 0 1.8 1.8 03/03/2006 15:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.9 0.3 1.5 0.4 91 13 165 165 1.8 0 1.8 1.6 03/03/2006 15:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.8 0.4 1.5 0.4 81 0 165 165 1.8 0 1.8 1.6 03/03/2006 15:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0.1 0.7 0.4 96 6 165 165 2.2 0 2.3 1.8 03/03/2006 15:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.6 0.3 1.5 0.4 118 17 165 165 2.1 0 2.3 1.8 03/03/2006 16:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0.1 0.7 0.4 123 4 165 165 1.9 0 2.1 1.8 03/03/2006 16:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0.1 0.7 0.4 127 5 165 165 1.9 0 1.8 1.8 03/03/2006 16:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 115 7 165 165 1.9 0 2.1 1.8 03/03/2006 16:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 101 22 165 165 1.9 0 2.1 1.8 03/03/2006 16:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 70 9 165 165 1.9 0 1.8 1.8 03/03/2006 16:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 83 0 165 165 1.9 0 1.8 1.8 03/03/2006 17:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 83 0 165 165 1.8 0 1.8 1.8 03/03/2006 17:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 87 5 165 165 1.8 0 1.8 1.6 03/03/2006 17:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 78 0 165 165 1.7 0 1.8 1.6 03/03/2006 17:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 61 7 165 165 1.7 0 1.8 1.6 03/03/2006 17:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 100 35 165 165 1.7 0 1.8 1.6 03/03/2006 17:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 99 6 165 165 1.7 0 1.8 1.6 03/03/2006 18:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 92 0 165 165 1.6 0 1.6 1.6 03/03/2006 18:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 92 0 165 165 1.5 0 1.6 1.4 03/03/2006 18:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 92 0 165 165 1.4 0 1.6 1.4 03/03/2006 18:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 92 0 165 165 1.3 0 1.4 1.4 03/03/2006 18:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 92 0 165 165 1.2 0 1.4 1.1 03/03/2006 18:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 92 0 165 165 1.1 0 1.4 0.9 03/03/2006 19:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 92 0 165 165 0.9 0 1.1 0.9 03/03/2006 19:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 92 0 165 165 0.8 0 0.9 0.7 03/03/2006 19:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 92 0 165 165 0.7 0 0.9 0.7 03/03/2006 19:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 92 0 165 165 0.7 0 0.9 0.7 03/03/2006 19:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 92 0 165 165 0.8 0 0.9 0.7 03/03/2006 19:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 92 0 165 165 0.9 0 1.1 0.9 03/03/2006 20:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 92 0 165 165 1 0 1.1 0.9 03/03/2006 20:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 92 0 165 165 1.1 0 1.4 0.9 03/03/2006 20:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 92 0 165 165 0.9 0 1.1 0.9 03/03/2006 20:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0.1 0.7 0.4 93 0 165 165 0.9 0 1.1 0.9 03/03/2006 20:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0.1 0.7 0.4 94 0 165 165 1 0 1.1 0.9 03/03/2006 20:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0.2 0.7 0.4 95 0 165 165 1.1 0 1.4 0.9 03/03/2006 21:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 96 0 165 165 1.1 0 1.4 0.9 03/03/2006 21:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 97 0 165 165 1 0 1.1 0.9 03/03/2006 21:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0.1 1.1 0.4 97 1 165 165 1 0 1.1 0.9 03/03/2006 21:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 1.2 0.2 1.5 0.7 106 2 165 165 1 0 1.4 0.9 03/03/2006 21:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 1.1 0.3 1.5 0.7 116 9 165 165 0.9 0 1.1 0.9 03/03/2006 21:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 1.2 0.2 1.9 0.7 145 6 165 165 0.9 0 1.1 0.9 03/03/2006 22:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 1.1 0.3 1.5 0.7 159 0 165 165 0.8 0 0.9 0.9 03/03/2006 22:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 1.1 0.3 1.5 0.4 159 0 165 165 0.8 0 0.9 0.9 03/03/2006 22:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 1.2 0.2 1.5 0.7 160 0 165 165 0.7 0 0.9 0.7 03/03/2006 22:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 1.3 0.2 1.9 0.7 160 0 165 165 0.5 0.1 0.7 0.2 03/03/2006 22:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 1.4 0.2 1.9 1.1 160 0 165 165 0.2 0 0.4 0.2 03/03/2006 22:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 1.4 0.2 1.9 0.7 160 0 165 165 0.2 0 0.4 0.2 03/03/2006 23:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 1.6 0.2 1.9 1.1 161 0 165 165 0.2 0 0.2 0.2 03/03/2006 23:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 1.7 0.2 1.9 1.1 162 0 165 165 0.1 0 0.2 -0.1 03/03/2006 23:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 1.9 0.2 2.3 1.1 164 0 165 165 0.1 0 0.2 -0.1 03/03/2006 23:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 1.9 0.3 2.6 1.1 164 3 165 165 0.2 0 0.4 0.2 03/03/2006 23:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 1.8 0.2 2.3 1.1 166 0 165 165 0.2 0 0.4 0.2 03/03/2006 23:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 1.9 0.3 2.6 1.5 166 0 165 165 0.2 0 0.4 0.2 03/04/2006 00:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 1.8 0.2 2.3 1.5 166 0 165 165 0.1 0 0.2 -0.1 03/04/2006 00:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 1.9 0.2 2.6 1.5 166 0 165 165 0.1 0 0.2 -0.1 03/04/2006 00:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 2 0.2 2.6 1.5 166 0 165 165 0 0 0.2 -0.1 03/04/2006 00:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 2 0.2 2.6 1.5 166 0 165 165 0 0 0.2 -0.1 03/04/2006 00:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 1.5 0.2 1.9 1.1 166 0 165 165 0 0 0.2 -0.1 03/04/2006 00:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 1.2 0.2 1.9 0.7 166 0 165 165 0 0 0.2 -0.1 03/04/2006 01:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.9 0.2 1.1 0.4 166 0 165 165 0 0 0.2 -0.1 03/04/2006 01:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 1.1 0.2 1.5 0.7 166 0 165 165 -0.1 0 -0.1 -0.3 03/04/2006 01:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 1.2 0.2 1.5 0.7 166 0 165 165 -0.2 0 -0.1 -0.3 03/04/2006 01:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 1.1 0.2 1.5 0.7 166 0 165 165 -0.3 0 -0.1 -0.3 03/04/2006 01:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 1.3 0.2 1.9 0.7 166 0 165 165 -0.4 0 -0.3 -0.5 03/04/2006 01:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 2.4 0.5 3 1.5 166 0 165 165 -0.5 0 -0.3 -0.5 03/04/2006 02:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 2.2 0.5 3.4 1.1 166 0 165 165 -0.3 0 -0.3 -0.5 03/04/2006 02:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 1.7 0.3 2.6 1.1 166 0 165 165 -0.4 0 -0.3 -0.5 03/04/2006 02:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 1.4 0.2 1.9 1.1 166 0 165 165 -0.6 0 -0.5 -0.8 03/04/2006 02:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 1.5 0.3 2.3 0.7 166 0 165 165 -0.8 0 -0.5 -0.8 03/04/2006 02:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 1.5 0.3 2.3 0.7 166 0 165 165 -0.9 0 -0.8 -0.8 03/04/2006 02:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 1.2 0.3 1.9 0.7 166 0 165 165 -0.8 0 -0.5 -0.8 03/04/2006 03:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 2 0.3 2.6 1.1 166 0 165 165 -0.6 0 -0.3 -0.8 03/04/2006 03:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 1.3 0.3 1.9 0.7 167 0 165 165 -0.3 0 -0.1 -0.5 03/04/2006 03:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.7 0.2 1.1 0.4 167 0 165 165 -0.3 0 -0.1 -0.3 03/04/2006 03:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.5 0.2 1.1 0.4 167 0 165 165 -0.2 0 -0.1 -0.3 03/04/2006 03:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 167 0 165 165 -0.3 0 -0.1 -0.5 03/04/2006 03:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 167 0 165 165 -0.5 0 -0.3 -0.8 03/04/2006 04:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 167 0 165 165 -0.5 0 -0.5 -0.5 03/04/2006 04:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 167 0 165 165 -0.5 0 -0.3 -0.5 03/04/2006 04:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 167 0 165 165 -0.5 0 -0.3 -0.8 03/04/2006 04:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 167 0 165 165 -0.4 0 -0.3 -0.5 03/04/2006 04:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 167 0 165 165 -0.4 0 -0.3 -0.5 03/04/2006 04:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 167 0 165 165 -0.5 0 -0.3 -0.5 03/04/2006 05:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 167 0 165 165 -0.4 0 -0.3 -0.5 03/04/2006 05:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 167 0 165 165 -0.5 0 -0.5 -0.8 03/04/2006 05:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 167 0 165 165 -0.5 0 -0.5 -0.8 03/04/2006 05:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0.2 1.1 0.4 167 0 165 165 -0.6 0 -0.5 -0.8 03/04/2006 05:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.7 0.4 167 0 165 165 -0.4 0 -0.3 -0.5 03/04/2006 05:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0.1 0.7 0.4 167 0 165 165 -0.3 0 -0.1 -0.5 03/04/2006 06:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.6 0.5 1.9 0.4 167 0 165 165 -0.3 0 -0.3 -0.5 03/04/2006 06:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.6 0.5 2.3 0.4 167 0 165 165 -0.3 0 -0.3 -0.5 03/04/2006 06:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.8 0.5 1.9 0.4 167 0 165 165 -0.3 0 -0.3 -0.5 03/04/2006 06:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.9 0.5 1.9 0.4 167 0 165 165 -0.2 0 -0.1 -0.3 03/04/2006 06:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.7 0.4 1.9 0.4 167 0 165 165 -0.2 0 -0.1 -0.3 03/04/2006 06:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 167 0 165 165 -0.2 0 -0.1 -0.3 03/04/2006 07:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.5 0.2 1.1 0.4 167 0 165 165 -0.1 0 0.2 -0.3 03/04/2006 07:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0.2 1.5 0.4 168 0 165 165 -0.1 0 -0.1 -0.3 03/04/2006 07:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0.1 0.7 0.4 168 0 165 165 -0.2 0 -0.1 -0.3 03/04/2006 07:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 168 0 165 165 -0.3 0 -0.1 -0.5 03/04/2006 07:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 168 0 165 165 -0.6 0 -0.5 -0.8 03/04/2006 07:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0.1 1.1 0.4 168 0 165 165 -0.6 0 -0.5 -0.8 03/04/2006 08:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 1.3 0.5 2.3 0.4 168 0 165 165 -0.5 0 -0.3 -0.5 03/04/2006 08:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 2.1 0.2 2.6 1.5 168 0 165 165 -0.4 0 -0.3 -0.5 03/04/2006 08:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 1.8 0.4 3 1.1 185 16 165 165 -0.2 0 -0.1 -0.5 03/04/2006 08:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 2.1 0.3 2.6 1.1 196 0 165 165 0 0 0.2 -0.3 03/04/2006 08:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 2.3 0.4 3 1.5 193 1 165 165 0.1 0 0.2 -0.1 03/04/2006 08:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 3 0.3 3.4 2.3 187 2 165 165 0.2 0 0.4 0.2 03/04/2006 09:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 2.3 0.5 3.4 1.5 176 5 165 165 0.3 0 0.4 0.2 03/04/2006 09:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 2.1 0.2 2.6 1.5 172 1 165 165 0.2 0 0.4 0.2 03/04/2006 09:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 1.9 0.2 2.6 1.5 171 0 165 165 0.3 0 0.7 0.2 03/04/2006 09:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.6 0.3 1.5 0.4 177 6 165 165 0.6 0.1 0.9 0.2 03/04/2006 09:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.7 0.4 177 6 165 165 0.8 0 0.9 0.7 03/04/2006 09:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 1 0.3 1.5 0.4 172 7 165 165 1.1 0.2 1.4 0.9 03/04/2006 10:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 1.6 0.4 2.6 0.7 184 8 165 165 1.8 0.2 2.3 1.4 03/04/2006 10:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 2.2 0.4 3.4 0.7 185 11 165 165 2.5 0.1 2.8 2.3 03/04/2006 10:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 2 0.5 3 0.7 172 10 165 165 2.2 0.2 2.6 1.8 03/04/2006 10:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 2 0.4 2.6 1.1 176 7 165 165 2 0.1 2.3 1.8 03/04/2006 10:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 1.9 0.4 2.6 1.1 171 10 165 165 2 0 2.6 1.8 03/04/2006 10:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 1.3 0.6 3 0.4 175 13 165 165 2.5 0.1 2.8 2.3 03/04/2006 11:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 1.8 0.5 2.6 0.7 186 12 165 165 2.6 0.1 2.8 2.6 03/04/2006 11:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 1.5 0.7 3 0.4 194 15 165 165 2.3 0 2.8 2.1 03/04/2006 11:20:00 0.4 0 0.7 0.4 0.4 0 0.4 0.4 0.6 0.6 2.3 0.4 193 17 194 165 2.3 0 2.6 1.8 03/04/2006 11:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.7 0.4 180 18 165 165 2 0.1 2.3 1.8 03/04/2006 11:40:00 0.4 0 0.4 0.4 0.4 0 1.1 0.4 0.4 0 0.7 0.4 171 17 165 165 2.1 0.3 2.8 1.8 03/04/2006 11:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.6 0.7 3.4 0.4 177 13 165 165 2.8 0.2 3 2.3 03/04/2006 12:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 2.3 0.7 3.4 0.4 173 11 165 165 2.1 0.2 2.6 1.8 03/04/2006 12:10:00 2 2.1 6.1 0.4 0.4 0 0.4 0.4 3 0.6 4.2 0.7 170 10 183 165 2.6 0.2 3 2.3 03/04/2006 12:20:00 4.9 0.5 6.5 3.4 1.6 2.5 8 0.4 3.5 0.4 4.6 2.3 184 9 185 165 2.7 0.1 3 2.3 03/04/2006 12:30:00 3.7 0.9 5.3 1.1 5.6 0.9 7.6 3 2.9 0.6 4.2 1.1 184 8 181 165 1.7 0.3 2.6 1.4 03/04/2006 12:40:00 2.8 1 4.6 0.4 4.8 0.8 6.5 2.6 2.6 0.5 3.8 1.1 193 11 195 165 2.4 0.5 3.3 1.4 03/04/2006 12:50:00 2.8 0.6 4.2 1.1 5.1 0.6 6.8 3.4 2.9 0.4 3.4 1.9 193 13 214 165 2.6 0.2 3.3 2.3 03/04/2006 13:00:00 2.9 0.8 4.2 0.4 5 0.8 6.8 3 2.8 0.5 3.8 0.7 199 11 185 165 2.5 0.1 2.8 2.1 03/04/2006 13:10:00 1.4 1 3.4 0.4 4 0.8 6.1 1.9 2.3 0.6 3.8 0.7 195 12 211 165 2 0.1 2.3 1.8 03/04/2006 13:20:00 2 0.8 3.8 0.4 3.9 0.7 5.7 2.3 2.3 0.6 3.4 0.7 175 12 154 165 2 0.1 2.6 1.8 03/04/2006 13:30:00 2.9 0.5 3.8 1.9 4.7 0.5 6.1 3.4 2.9 0.4 3.8 1.9 170 7 172 165 2 0.2 2.6 1.6 03/04/2006 13:40:00 2.4 0.6 3.4 0.7 4.1 0.5 5.3 2.6 2.5 0.5 3.4 1.5 166 5 167 165 1.4 0 1.6 1.4 03/04/2006 13:50:00 2.8 0.5 4.2 1.5 4.6 0.5 5.7 3.4 2.8 0.4 4.2 1.9 170 6 166 165 1.4 0 1.6 1.4 03/04/2006 14:00:00 2.5 0.4 3.8 1.5 4.3 0.5 6.1 3 2.5 0.4 3.4 1.5 170 14 170 165 1.6 0.2 2.1 1.4 03/04/2006 14:10:00 2.6 0.7 4.9 1.1 4.5 0.8 7.2 3 2.6 0.5 4.2 1.1 171 7 177 165 1.8 0.1 2.1 1.4 03/04/2006 14:20:00 2.7 0.7 4.2 0.4 4.6 0.7 6.5 2.6 2.7 0.5 3.8 1.5 177 12 168 165 1.5 0.1 1.6 1.4 03/04/2006 14:30:00 3.1 0.9 4.9 0.7 5.1 1 7.2 2.6 2.9 0.5 4.2 1.1 194 12 206 165 1.3 0 1.6 1.1 03/04/2006 14:40:00 2.8 0.9 4.6 0.4 4.8 0.9 6.8 1.9 2.7 0.5 3.8 1.5 188 13 204 165 1.2 0 1.4 0.9 03/04/2006 14:50:00 3.9 0.9 5.3 1.9 6 1.1 8 3 3.4 0.5 4.6 1.9 189 12 192 165 1 0.1 1.4 0.9 03/04/2006 15:00:00 4.2 0.8 6.1 1.5 6.4 1.1 8.8 3.4 4.8 1.8 8.8 2.3 189 8 194 165 0.7 0 0.9 0.4 03/04/2006 15:10:00 4.7 0.7 6.5 3 7 1 9.1 4.6 7.2 1 9.9 5.3 189 7 197 165 0.5 0 0.7 0.2 03/04/2006 15:20:00 4.7 0.4 6.1 3.8 7.1 0.6 8.8 5.3 7.3 0.8 9.9 4.9 186 10 189 165 0.4 0 0.7 0.2 03/04/2006 15:30:00 4.9 0.7 6.5 3.4 7.4 1.1 9.9 4.9 7.6 1 10.3 5.3 185 11 193 165 0.3 0 0.7 0.2 03/04/2006 15:40:00 5.1 0.5 6.5 3.8 7.5 0.8 9.9 4.9 7.8 0.8 9.9 6.1 186 8 197 165 0.1 0 0.2 -0.1 03/04/2006 15:50:00 4.6 0.6 6.5 3.4 6.8 0.9 8.8 4.6 7.1 0.8 9.1 4.9 180 9 184 165 0 0 0.2 -0.1 03/04/2006 16:00:00 5.3 0.6 6.5 3.8 7.8 0.8 9.5 5.3 8.2 1 10.7 5.7 185 7 187 165 -0.1 0 0.2 -0.3 03/04/2006 16:10:00 5 0.6 6.5 3.4 7.3 0.9 9.5 4.9 7.7 0.9 10.3 4.9 185 9 192 165 -0.1 0 -0.1 -0.3 03/04/2006 16:20:00 6.1 0.6 7.6 4.6 9 1 12.2 6.1 9.5 1 12.6 6.5 185 9 196 165 -0.2 0 -0.1 -0.3 03/04/2006 16:30:00 5.5 0.6 6.8 3.8 8 0.9 10.7 5.3 8.4 1 10.7 5.7 178 6 183 165 -0.1 0 0.2 -0.3 03/04/2006 16:40:00 5.1 0.6 6.5 3.8 7.4 0.8 9.9 5.7 7.7 1 9.9 5.3 180 8 181 165 0.1 0 0.2 -0.1 03/04/2006 16:50:00 5.8 0.6 7.2 4.6 8.3 0.8 11.1 6.1 8.6 0.8 11.5 6.5 186 7 186 165 0.2 0 0.4 0.2 03/04/2006 17:00:00 5.1 0.6 6.5 3.4 7.2 0.9 9.1 5.3 7.5 0.8 9.9 5.3 188 6 189 165 0.2 0 0.2 0.2 03/04/2006 17:10:00 5.1 0.4 6.1 4.2 7.3 0.5 8.8 5.7 7.7 0.6 9.1 5.7 196 6 191 165 0.2 0 0.4 0.2 03/04/2006 17:20:00 5.1 0.6 6.5 3.4 7.3 0.8 9.1 4.6 7.5 0.9 9.5 4.9 194 6 191 165 0.2 0 0.4 0.2 03/04/2006 17:30:00 4.8 0.4 6.1 3.8 6.9 0.6 8.4 5.3 7.1 0.8 8.8 5.3 187 7 193 165 0.2 0 0.4 0.2 03/04/2006 17:40:00 5 0.4 6.5 3.8 7.2 0.6 9.1 5.3 7.4 0.8 8.8 4.9 187 8 180 165 0.2 0 0.2 0.2 03/04/2006 17:50:00 4.2 0.5 5.3 3 6 0.7 8 3.8 6.1 0.6 8 4.9 191 7 194 165 0.2 0 0.2 0.2 03/04/2006 18:00:00 4.4 0.5 5.3 3 6.2 0.7 8 4.6 6.4 0.6 8 4.9 191 6 188 165 0.2 0 0.2 0.2 03/04/2006 18:10:00 4.5 0.4 5.7 3.4 6.3 0.6 8 4.9 6.6 0.6 8.4 5.3 184 7 177 165 0.1 0 0.2 -0.1 03/04/2006 18:20:00 5.1 0.5 6.1 3.8 7.2 0.7 8.4 5.3 7.5 0.7 8.8 5.7 183 6 187 165 0 0 0.2 -0.1 03/04/2006 18:30:00 4.5 0.5 5.7 3.4 6.3 0.7 8 4.9 6.6 0.7 8.4 4.9 181 6 192 165 -0.2 0 -0.1 -0.3 03/04/2006 18:40:00 3.7 0.4 4.6 2.6 5.2 0.4 6.5 3.8 5.6 0.5 7.2 4.6 179 6 184 165 -0.2 0 -0.1 -0.3 03/04/2006 18:50:00 4.3 0.3 4.9 3.4 6 0.4 6.8 4.9 6.3 0.4 7.2 4.6 179 3 180 165 -0.2 0 -0.1 -0.5 03/04/2006 19:00:00 4 0.4 4.9 2.6 5.6 0.5 6.8 4.2 5.9 0.5 7.2 4.6 180 5 190 165 -0.2 0 -0.1 -0.3 03/04/2006 19:10:00 4.1 0.2 4.6 3.4 5.7 0.2 6.1 4.9 6 0.3 6.8 4.9 178 4 183 165 -0.2 0 -0.1 -0.3 03/04/2006 19:20:00 3.9 0.2 4.6 3.4 5.4 0.3 6.1 4.6 5.8 0.3 6.5 4.9 179 3 182 165 -0.2 0 -0.1 -0.3 03/04/2006 19:30:00 3.7 0.4 4.6 3 5.3 0.5 6.5 4.2 5.6 0.5 6.5 4.6 176 4 176 165 -0.2 0 -0.1 -0.3 03/04/2006 19:40:00 3.7 0.5 4.9 2.6 5.2 0.5 6.5 4.2 5.4 0.6 6.8 4.2 174 6 171 165 -0.1 0 -0.1 -0.3 03/04/2006 19:50:00 4.4 0.3 5.3 3.8 6.1 0.5 7.6 5.3 6.2 0.5 8 4.9 176 5 179 165 -0.1 0 0.2 -0.3 03/04/2006 20:00:00 5.7 0.5 6.8 4.6 7.9 0.7 9.9 6.5 8.3 0.8 10.3 6.8 174 5 177 165 0.1 0 0.2 -0.3 03/04/2006 20:10:00 6 0.5 6.8 4.9 8.5 0.7 9.9 6.8 9 0.8 10.7 6.8 170 7 170 165 0.2 0 0.4 0.2 03/04/2006 20:20:00 6.5 0.6 7.6 4.9 9.3 1 11.5 6.8 9.9 1.1 12.2 6.8 168 14 165 165 0.4 0 0.7 0.2 03/04/2006 20:30:00 7.3 0.4 8 6.1 10.6 0.6 11.8 8.8 11.3 0.7 13.3 8.8 164 20 167 165 0.5 0 0.7 0.4 03/04/2006 20:40:00 6.9 0.4 8 6.1 10.1 0.6 12.2 8.8 10.7 0.7 13 8.4 165 15 165 165 0.5 0 0.7 0.2 03/04/2006 20:50:00 7.2 0.5 8 6.1 10.7 0.6 12.2 9.1 11.4 0.6 12.6 9.9 166 8 168 165 0.5 0 0.7 0.4 03/04/2006 21:00:00 7.4 0.5 8 6.5 11 0.7 12.6 9.1 11.7 0.9 13.7 9.1 166 11 167 165 0.5 0 0.7 0.4 03/04/2006 21:10:00 7.5 0.4 8.4 6.5 11.3 0.7 13 9.5 11.9 1 13.7 8.8 166 10 175 165 0.5 0 0.7 0.4 03/04/2006 21:20:00 8 1.2 13.7 6.5 11.8 0.7 13.3 9.9 12.5 0.9 14.9 9.9 167 14 165 165 0.5 0 0.7 0.4 03/04/2006 21:30:00 12.2 0.6 13.3 10.3 11.7 0.6 13 9.9 12.6 0.7 13.7 10.3 169 9 168 165 0.6 0 0.7 0.4 03/04/2006 21:40:00 11.7 0.6 13.3 9.9 11.2 0.5 13 9.5 12 0.8 13.7 9.5 169 11 173 165 0.6 0 0.7 0.4 03/04/2006 21:50:00 11.2 0.7 12.6 9.1 10.7 0.6 12.2 8.8 11.5 0.9 13.3 8.8 169 7 173 165 0.6 0 0.9 0.2 03/04/2006 22:00:00 12.2 0.6 13.7 10.3 11.7 0.6 13.3 9.9 12.4 0.7 14.5 10.7 169 11 166 165 0.5 0 0.9 0.2 03/04/2006 22:10:00 11.7 0.5 12.6 9.9 11.2 0.4 12.2 9.9 12 0.5 13 9.9 166 10 166 165 0.4 0.1 0.7 0.2 03/04/2006 22:20:00 12.6 0.8 14.5 10.3 12.2 0.8 14.5 10.3 13 0.9 14.9 11.1 165 17 164 165 0.3 0 0.7 0.2 03/04/2006 22:30:00 11.9 1 14.1 9.5 11.5 1 13.3 9.5 12.2 1 14.5 9.9 163 15 165 165 0.2 0 0.4 0.2 03/04/2006 22:40:00 11.9 0.8 13.7 9.9 11.5 0.7 13 9.5 12.2 0.8 14.1 9.9 168 10 173 165 0.2 0 0.2 0.2 03/04/2006 22:50:00 11.1 0.8 14.1 9.1 10.7 0.8 13.3 9.1 11.3 0.8 13.7 8.8 169 10 166 165 0.2 0 0.2 -0.1 03/04/2006 23:00:00 11 0.8 12.6 8.4 10.5 0.7 11.8 8.8 11.2 0.9 13.3 9.1 173 5 174 165 0.2 0 0.2 -0.1 03/04/2006 23:10:00 10 0.7 11.8 7.6 9.6 0.6 11.1 7.6 10.2 0.8 12.2 7.6 171 11 176 165 0.1 0 0.2 -0.1 03/04/2006 23:20:00 8.9 0.4 9.9 7.6 8.5 0.4 9.5 7.2 9.2 0.4 10.3 7.6 171 4 162 165 0 0 0.2 -0.1 03/04/2006 23:30:00 9.3 0.4 10.3 8.4 9 0.4 9.9 8 9.6 0.4 10.7 8 171 5 178 165 -0.1 0 0.2 -0.3 03/04/2006 23:40:00 9.6 0.4 10.3 8.4 9.2 0.4 9.9 8 9.9 0.5 11.5 8.4 172 4 178 165 -0.1 0 -0.1 -0.3 03/04/2006 23:50:00 9.7 0.5 11.1 8.4 9.4 0.4 10.3 8 10 0.5 11.1 8.4 172 5 171 165 -0.1 0 -0.1 -0.3 03/05/2006 00:00:00 8.9 0.5 10.3 7.6 8.6 0.5 9.5 7.6 9.1 0.5 10.7 7.6 170 4 186 165 -0.1 0 0.2 -0.3 03/05/2006 00:10:00 8 0.4 9.1 6.8 7.8 0.4 8.8 6.8 8.2 0.5 9.1 6.5 167 10 173 165 0.1 0 0.2 -0.1 03/05/2006 00:20:00 7.5 0.5 8.4 6.1 7.4 0.5 8.4 6.1 7.7 0.5 8.8 6.5 162 14 162 165 0.1 0 0.2 -0.1 03/05/2006 00:30:00 7.2 0.4 8 6.1 7.2 0.4 8 6.1 7.4 0.4 8.4 6.1 154 4 154 165 0.1 0 0.2 -0.1 03/05/2006 00:40:00 6.9 0.5 8.8 5.7 6.9 0.5 8.4 5.7 7.1 0.5 8.8 5.7 154 5 146 165 0.2 0 0.2 0.2 03/05/2006 00:50:00 8.6 0.7 9.9 6.8 8.5 0.7 9.9 6.8 9 0.7 10.7 7.6 158 6 164 165 0.2 0 0.4 0.2 03/05/2006 01:00:00 9.9 0.5 11.1 8.4 9.9 0.5 11.5 8.4 10.3 0.6 11.5 8.4 162 12 162 165 0.3 0 0.7 0.2 03/05/2006 01:10:00 10.1 0.7 11.5 8.4 10.1 0.7 11.5 8 10.6 0.8 11.8 9.1 165 5 165 165 0.4 0 0.7 0.2 03/05/2006 01:20:00 10.2 0.7 12.2 8.8 10.1 0.6 11.8 8.4 10.5 0.6 12.2 8.8 163 11 166 165 0.4 0 0.7 0.2 03/05/2006 01:30:00 9.6 0.4 10.7 8.8 9.4 0.3 10.3 8.8 9.9 0.4 11.1 8.8 167 9 174 165 0.4 0 0.7 0.2 03/05/2006 01:40:00 8.5 0.5 9.5 7.2 8.3 0.5 9.5 7.2 8.8 0.5 9.9 7.6 165 8 165 165 0.4 0 0.7 0.2 03/05/2006 01:50:00 7.4 0.4 8.4 6.5 7.2 0.4 8.4 6.1 7.7 0.4 8.8 6.8 158 8 162 165 0.4 0 0.7 0.2 03/05/2006 02:00:00 6.9 0.5 8.4 5.7 6.7 0.4 8 5.7 7.1 0.4 8 5.7 152 3 158 165 0.4 0 0.7 0.2 03/05/2006 02:10:00 6.4 0.5 8 5.3 6.3 0.5 7.6 4.9 6.7 0.5 8 5.3 152 4 159 165 0.5 0 0.7 0.2 03/05/2006 02:20:00 6.3 0.5 7.2 4.9 6.2 0.5 7.2 4.6 6.7 0.6 8 5.3 155 6 164 165 0.7 0.1 0.9 0.7 03/05/2006 02:30:00 6.7 0.5 7.6 5.3 6.6 0.5 7.2 5.3 7.1 0.6 8.4 5.3 158 3 160 165 0.8 0 0.9 0.7 03/05/2006 02:40:00 6.4 0.6 7.6 5.3 6.3 0.5 7.6 4.9 6.8 0.6 8.4 4.9 161 4 164 165 0.8 0 0.9 0.7 03/05/2006 02:50:00 6 0.3 6.8 4.9 5.8 0.3 6.5 4.9 6.4 0.3 7.2 5.7 156 3 151 165 0.8 0 0.9 0.9 03/05/2006 03:00:00 6.5 0.4 7.6 5.3 6.5 0.4 7.2 5.3 6.8 0.4 7.6 5.3 149 2 151 165 0.8 0 0.9 0.9 03/05/2006 03:10:00 5.2 0.8 6.5 3.4 5.1 0.7 6.5 3.4 5.5 0.6 6.8 3.8 156 4 153 165 0.8 0 0.9 0.9 03/05/2006 03:20:00 3.7 0.4 4.6 2.6 3.7 0.4 4.2 2.6 4.1 0.4 4.9 3 155 3 164 165 0.8 0 0.9 0.9 03/05/2006 03:30:00 3.4 0.5 4.9 1.5 3.3 0.5 4.9 1.1 3.8 0.4 4.9 2.6 164 10 141 165 0.9 0 1.1 0.9 03/05/2006 03:40:00 3.8 0.5 5.7 2.6 3.8 0.5 6.1 2.6 4.2 0.5 5.7 3 154 7 144 165 0.8 0 1.1 0.9 03/05/2006 03:50:00 1.6 0.7 3 0.4 1.4 0.9 3 0.4 2.2 0.6 3.4 1.1 162 2 162 165 0.8 0 0.9 0.7 03/05/2006 04:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.6 0.3 1.5 0.4 162 0 165 165 0.7 0 0.9 0.7 03/05/2006 04:10:00 0.4 0 0.4 0.4 1.4 1.7 4.6 0.4 2.7 1.5 4.9 0.4 170 5 165 165 0.7 0 0.9 0.4 03/05/2006 04:20:00 0.4 0 0.4 0.4 2.3 1.2 4.6 0.4 2.7 1.1 4.6 0.7 173 0 165 165 0.8 0 0.9 0.7 03/05/2006 04:30:00 1.6 2.2 7.6 0.4 3 2.3 8 0.4 3 1.9 7.2 0.4 213 56 300 165 0.8 0 0.9 0.7 03/05/2006 04:40:00 7.5 1.9 10.7 4.2 8.1 2 11.8 4.6 7.8 2.4 11.5 4.2 312 7 303 165 0.6 0 0.9 0.4 03/05/2006 04:50:00 10.5 1.3 13.7 7.2 11.1 1.3 14.5 7.6 11.2 1.5 14.5 7.6 317 6 320 165 0.3 0.1 0.7 0.2 03/05/2006 05:00:00 12.2 1.6 16.1 8.4 13 1.6 17.2 9.1 12.5 1.5 16.8 8.8 313 7 304 165 0.2 0 0.2 0.2 03/05/2006 05:10:00 13.5 1.4 17.6 9.9 14.4 1.4 18.7 10.7 12.4 1.7 18.3 8.4 305 8 299 165 0.2 0 0.4 0.2 03/05/2006 05:20:00 13.9 1.7 17.9 8.8 15 1.8 19.1 9.5 12.9 2.2 19.1 9.1 296 7 292 165 0.3 0 0.4 0.2 03/05/2006 05:30:00 13.2 1.2 16.8 9.9 14.2 1.2 17.6 11.5 12.4 1.8 16.8 8.8 293 7 302 165 0.4 0 0.7 0.2 03/05/2006 05:40:00 13.3 1.2 16.4 9.9 14.1 1.2 17.2 11.1 11.9 1.5 15.3 8.4 301 8 303 165 0.4 0 0.7 0.2 03/05/2006 05:50:00 14.5 1.4 18.7 11.8 15.3 1.5 19.9 11.5 13.1 1.7 17.6 9.1 303 7 303 165 0.2 0 0.4 0.2 03/05/2006 06:00:00 15.6 1.2 18.3 13 16.3 1.3 19.1 13.7 15.8 1.4 20.2 11.8 311 6 304 165 0.1 0 0.2 -0.1 03/05/2006 06:10:00 21.2 2.3 25.2 14.1 21.9 2.2 25.6 15.3 21.7 2.5 27.1 15.3 312 5 311 165 -0.1 0.1 0.2 -0.3 03/05/2006 06:20:00 23.2 1.7 27.5 18.3 23.5 1.7 27.9 18.3 24 1.9 30.6 18.7 319 8 321 165 -0.5 0 -0.3 -0.5 03/05/2006 06:30:00 21.9 1.8 25.6 16.8 22.1 1.8 26 17.2 22.8 2.2 27.1 17.2 322 6 318 165 -0.5 0 -0.3 -0.8 03/05/2006 06:40:00 21.6 1.8 26.8 16.8 21.9 1.9 26.8 17.6 22.6 2.2 28.3 16.8 321 6 326 165 -0.3 0 -0.3 -0.5 03/05/2006 06:50:00 22.2 1.9 27.5 16.8 22.6 2 28.7 17.6 23.5 2.1 29.1 17.9 321 7 309 165 -0.3 0 -0.1 -0.5 03/05/2006 07:00:00 22.8 1.8 27.1 16.4 23.2 1.9 28.3 16.1 23.8 2.1 29.4 18.7 321 6 310 165 -0.3 0 -0.3 -0.5 03/05/2006 07:10:00 21 1.7 26.3 16.4 21.4 1.7 26.8 16.8 21.7 1.8 27.5 17.2 318 7 321 165 -0.4 0 -0.3 -0.5 03/05/2006 07:20:00 22.3 1.7 26 17.9 22.7 1.8 26.8 17.9 23 2 27.9 17.2 317 6 313 165 -0.6 0 -0.5 -0.8 03/05/2006 07:30:00 20.4 2 25.2 14.1 20.9 2.1 25.6 14.9 21.1 2.5 26 13.3 316 5 318 165 -0.6 0 -0.5 -0.8 03/05/2006 07:40:00 23 1.5 27.1 16.4 23.3 1.5 27.9 16.4 24 1.8 28.7 16.8 316 5 313 165 -0.8 0 -0.5 -1 03/05/2006 07:50:00 21 1.5 24.8 17.6 21.2 1.6 25.2 17.6 21.7 1.9 26.3 16.8 317 5 318 165 -0.9 0 -0.8 -1.2 03/05/2006 08:00:00 21.8 1.8 26 17.2 22 1.9 26.8 17.2 22.4 2.2 27.5 17.6 317 5 316 165 -0.9 0 -0.8 -1 03/05/2006 08:10:00 20.5 1.6 24 14.9 20.6 1.7 24.4 14.5 21.1 1.8 25.2 15.6 319 6 311 165 -0.8 0 -0.5 -0.8 03/05/2006 08:20:00 20.9 1.5 24.4 16.4 21.1 1.6 24.4 16.8 21.6 1.8 25.6 15.6 317 5 318 165 -0.6 0 -0.5 -0.8 03/05/2006 08:30:00 22.1 1.7 25.6 17.2 22.3 1.8 26 17.2 23 2.1 27.1 16.4 317 5 323 165 -0.5 0 -0.3 -0.8 03/05/2006 08:40:00 20.7 1.8 24.8 14.5 20.8 1.9 24.8 13.7 21.9 2.2 27.5 14.5 318 6 319 165 -0.5 0 -0.5 -0.8 03/05/2006 08:50:00 19.6 1.4 22.6 16.1 19.9 1.5 22.9 16.1 20.8 1.7 24.4 16.1 317 6 311 165 -0.6 0 -0.5 -0.8 03/05/2006 09:00:00 18.8 1.7 22.9 13.7 18.9 1.8 23.3 14.1 19.9 2.1 24.8 14.9 319 6 320 165 -0.6 0 -0.5 -0.8 03/05/2006 09:10:00 17.4 1.7 21.8 13 17.3 1.7 22.1 12.6 18.3 2.1 22.9 13.3 320 7 313 165 -0.6 0 -0.5 -0.8 03/05/2006 09:20:00 18.9 1.4 22.6 15.3 19 1.5 22.9 15.3 19.9 1.7 23.7 15.3 317 5 312 165 -0.5 0 -0.5 -0.8 03/05/2006 09:30:00 18 1.5 21.4 13.3 18.2 1.5 21.8 13.7 18.6 1.6 22.6 14.9 317 6 307 165 -0.5 0 -0.3 -0.5 03/05/2006 09:40:00 18.5 2 23.3 11.8 18.7 2.1 23.3 12.6 19.1 2.3 24.8 13 318 6 320 165 -0.4 0 -0.3 -0.5 03/05/2006 09:50:00 19.2 1.6 23.3 14.9 19.3 1.6 23.3 14.9 20.1 1.8 24.4 14.5 318 5 327 165 -0.3 0 -0.3 -0.5 03/05/2006 10:00:00 18.7 1.7 23.3 13 18.7 1.7 23.3 13.3 19.3 1.8 24 14.1 319 6 315 165 -0.3 0 -0.1 -0.5 03/05/2006 10:10:00 18.7 1.7 22.6 13.7 18.8 1.7 22.9 14.1 19.3 1.9 24.4 13.7 320 6 312 165 -0.2 0 -0.1 -0.3 03/05/2006 10:20:00 18.2 1.8 21.8 12.6 18.4 1.8 22.1 12.6 18.9 1.9 22.6 12.2 318 6 326 165 0.1 0.1 0.4 -0.3 03/05/2006 10:30:00 18.9 1.7 22.6 13.3 19.3 1.7 22.9 14.1 19.4 1.9 23.3 13.7 320 6 322 165 0.4 0 0.7 0.2 03/05/2006 10:40:00 17.8 1.9 23.3 12.6 18 1.9 23.7 11.8 17.6 2.2 23.3 11.8 317 6 319 165 0.2 0.1 0.7 0.2 03/05/2006 10:50:00 16.9 2 22.1 11.1 17 2 22.6 11.5 15.9 2.1 21 9.5 315 9 305 165 0.1 0 0.2 -0.1 03/05/2006 11:00:00 16.3 1.9 22.6 11.5 16.4 2 22.1 11.5 15.4 2 21.8 10.7 313 8 307 165 0 0 0.2 -0.1 03/05/2006 11:10:00 14.7 1.7 20.2 11.1 14.7 1.7 19.9 11.1 14 1.7 18.3 8.4 316 7 302 165 0.1 0 0.2 -0.1 03/05/2006 11:20:00 14.5 2.2 19.5 9.1 14.6 2.2 19.5 9.5 14 2.4 19.5 9.1 317 9 314 165 0.1 0 0.2 -0.1 03/05/2006 11:30:00 15.2 2 19.9 11.1 15.2 2.1 20.2 10.3 14.6 2.3 19.5 9.1 316 7 314 165 0.2 0 0.4 0.2 03/05/2006 11:40:00 15.4 1.6 20.2 11.5 15.4 1.7 20.2 11.8 14.9 2 20.2 8.8 317 6 320 165 0.4 0 0.7 0.2 03/05/2006 11:50:00 15.8 1.6 19.5 10.7 15.8 1.7 19.5 10.3 15.1 1.7 19.9 9.9 317 8 322 165 0.7 0.1 0.9 0.4 03/05/2006 12:00:00 16.5 1.9 21 11.8 16.6 1.9 21.4 12.2 15.7 2 21 10.3 314 9 315 165 0.8 0 1.1 0.7 03/05/2006 12:10:00 17.7 2.7 23.7 11.5 17.7 2.6 23.7 10.7 16.9 2.8 22.6 11.1 316 9 313 165 1.2 0 1.4 0.9 03/05/2006 12:20:00 17.9 1.7 21.8 13.7 17.7 1.8 21.8 13 17.2 2.3 23.7 11.5 317 7 317 165 1.2 0.1 1.6 0.9 03/05/2006 12:30:00 16.6 1.7 20.6 11.8 16.4 1.7 20.6 11.5 16.3 2 21.4 9.1 319 7 322 165 1.4 0 1.6 1.4 03/05/2006 12:40:00 17.4 1.8 22.1 13 17.3 1.8 22.1 12.2 16.6 2.1 21.8 10.3 316 6 304 165 1.2 0 1.4 1.1 03/05/2006 12:50:00 17.7 2.1 22.9 12.6 17.6 2.1 22.1 12.6 17.2 2.5 22.9 9.9 317 7 307 165 1.4 0 1.6 1.4 03/05/2006 13:00:00 16.4 1.8 22.6 11.8 16.3 1.7 22.6 12.2 15.9 1.9 21 9.5 316 8 315 165 1.5 0 1.6 1.4 03/05/2006 13:10:00 17.4 1.6 22.1 13.3 17.2 1.6 22.1 13.3 16.7 2 21.4 9.1 316 6 313 165 1.4 0 1.6 1.4 03/05/2006 13:20:00 16.9 1.6 20.6 12.2 16.9 1.7 20.6 12.2 16 1.8 20.2 11.5 314 6 310 165 1.4 0 1.6 1.4 03/05/2006 13:30:00 17.2 2 22.6 11.8 17.1 2 22.6 11.8 16.5 2.3 23.3 10.7 316 7 314 165 1.5 0 1.6 1.4 03/05/2006 13:40:00 18.4 1.8 22.6 13.7 18.3 1.8 22.6 13.7 17.5 2 22.9 10.3 315 6 325 165 1.5 0.1 1.6 1.4 03/05/2006 13:50:00 17.6 1.4 21 14.1 17.5 1.4 21 13.7 17 2 20.6 11.5 316 6 311 165 1.4 0 1.6 1.4 03/05/2006 14:00:00 18.7 1.8 24 12.6 18.6 1.7 24 13 17.6 2 23.3 10.3 315 7 318 165 1.2 0 1.4 0.9 03/05/2006 14:10:00 15.9 2.1 21.4 11.1 15.8 2.1 21.4 11.1 14.8 2.3 21.4 8.4 314 9 310 165 1.4 0.1 1.6 0.9 03/05/2006 14:20:00 16.5 2.3 21.8 10.7 16.3 2.3 22.1 11.1 15.8 2.5 21.8 10.3 316 8 319 165 1.5 0 1.6 1.4 03/05/2006 14:30:00 16.7 2.4 22.1 11.1 16.6 2.4 22.1 10.7 15.7 2.3 21.4 9.5 315 9 321 165 1.5 0.1 1.8 1.4 03/05/2006 14:40:00 16.8 2 21.4 11.8 16.7 1.9 21 12.2 15.7 2.3 22.1 10.7 313 8 314 165 1.7 0 1.8 1.6 03/05/2006 14:50:00 17.2 1.8 21.4 11.8 17.1 1.8 21.4 12.2 16.3 2.2 20.2 10.7 315 7 314 165 1.5 0 1.6 1.4 03/05/2006 15:00:00 17.2 2.6 22.9 11.1 17 2.6 22.6 11.1 15.6 3.1 23.7 9.5 313 9 314 165 1.5 0 1.8 1.4 03/05/2006 15:10:00 19.3 2 25.2 12.6 19.2 2 25.2 12.2 18.1 2.2 25.2 11.1 314 6 316 165 1.4 0.1 1.8 1.4 03/05/2006 15:20:00 18.4 1.8 22.9 13.7 18.3 1.9 22.6 13.3 17.5 2 21.8 11.5 316 6 307 165 1.4 0 1.6 1.4 03/05/2006 15:30:00 17.4 1.9 22.9 12.6 17.3 1.9 22.6 12.2 15.7 2.1 21 10.7 312 9 304 165 1.2 0.1 1.6 0.9 03/05/2006 15:40:00 14.7 1.7 17.9 11.1 14.6 1.7 18.3 10.3 13.8 1.9 18.7 9.9 316 8 321 165 1.4 0 1.6 1.4 03/05/2006 15:50:00 16.4 1.9 21 11.8 16.2 2 20.6 10.7 15.4 2.1 20.6 9.9 314 7 312 165 1.4 0 1.6 1.4 03/05/2006 16:00:00 17.5 1.9 21.4 11.5 17.3 1.9 21.4 11.5 16.7 2.2 21.4 10.3 315 7 311 165 1.4 0 1.6 1.4 03/05/2006 16:10:00 16.2 1.9 21.4 11.8 16.1 1.9 21 11.1 15.5 2.1 20.2 9.9 319 8 323 165 1.4 0 1.6 1.4 03/05/2006 16:20:00 15.3 2.2 19.9 9.9 15.1 2.3 19.9 9.9 14.4 2.2 19.5 8.8 317 8 316 165 1.4 0 1.6 1.4 03/05/2006 16:30:00 15.1 1.5 18.7 10.7 15 1.5 18.7 10.3 14.6 1.7 18.3 9.1 318 7 314 165 1.4 0 1.4 1.4 03/05/2006 16:40:00 15.1 2.1 19.5 9.5 15 2 19.1 9.1 14 2.2 19.5 8.8 315 8 316 165 1.1 0 1.4 0.9 03/05/2006 16:50:00 12.5 1.2 16.1 9.1 12.3 1.2 15.6 8.4 11.8 1.6 16.8 8.4 316 8 321 165 1.1 0 1.4 0.9 03/05/2006 17:00:00 13 2 19.9 8.4 12.9 2 19.5 8.4 12.4 2.1 17.9 8.4 316 6 310 165 0.9 0 1.1 0.9 03/05/2006 17:10:00 14.8 1.7 18.7 11.1 14.6 1.7 18.7 10.7 13.3 1.7 17.9 8 313 7 308 165 0.7 0 0.9 0.7 03/05/2006 17:20:00 14 1.4 17.6 9.1 13.9 1.5 17.6 8.4 12.4 1.6 16.8 7.6 311 8 303 165 0.5 0 0.7 0.2 03/05/2006 17:30:00 16.8 1.7 21 12.2 16.7 1.7 21 11.5 15 2.2 20.2 9.5 311 6 314 165 0.4 0.1 0.7 0.2 03/05/2006 17:40:00 15.9 1.7 21 10.7 15.9 1.7 20.6 10.7 15 2 19.9 9.5 312 7 306 165 -0.1 0.1 0.2 -0.3 03/05/2006 17:50:00 16.3 1.5 20.6 12.6 16.2 1.4 20.6 13 14.6 1.9 18.7 9.9 311 7 313 165 -0.3 0 -0.1 -0.5 03/05/2006 18:00:00 14.6 1.3 18.3 11.1 14.5 1.3 17.9 11.5 14 1.7 17.6 8.8 314 8 310 165 -0.5 0 -0.3 -0.5 03/05/2006 18:10:00 13.8 2 20.2 9.5 13.7 2.1 21 9.5 12.8 2.3 19.1 8 311 8 322 165 -0.6 0 -0.5 -0.8 03/05/2006 18:20:00 14.7 1.7 20.6 11.1 14.6 1.7 21.4 10.7 12.3 2.2 18.7 8 304 9 298 165 -0.7 0.1 -0.5 -0.8 03/05/2006 18:30:00 15.4 2 20.6 9.9 15.4 2.1 21 10.3 13.4 2.3 20.2 8.8 306 8 311 165 -0.8 0.1 -0.5 -0.8 03/05/2006 18:40:00 13.8 1.6 17.6 9.9 13.7 1.6 17.6 9.5 12.4 1.7 16.8 8.4 309 9 310 165 -0.9 0 -0.8 -1 03/05/2006 18:50:00 16.2 1.5 19.9 12.6 16.1 1.5 19.5 12.2 13.2 1.9 18.7 8 303 7 305 165 -0.9 0 -0.8 -1.2 03/05/2006 19:00:00 17.5 2 22.1 11.1 17.4 2.1 22.1 11.5 14.3 2.2 21 9.9 305 7 300 165 -0.9 0 -0.8 -1 03/05/2006 19:10:00 16.5 2.2 22.1 12.2 16.4 2.3 22.1 12.2 13.4 2.1 19.9 8.8 304 8 294 165 -0.9 0 -0.8 -1.2 03/05/2006 19:20:00 14.9 1.5 19.1 11.5 14.9 1.5 19.1 11.1 13.2 1.9 19.1 9.5 309 7 301 165 -1 0 -0.8 -1.2 03/05/2006 19:30:00 13.6 1.3 17.6 9.9 13.5 1.4 17.2 9.5 12.2 1.5 15.6 8.8 312 6 307 165 -1.2 0 -1 -1.4 03/05/2006 19:40:00 12.2 1.1 15.3 8.8 12 1.1 15.3 8.8 11.9 1.2 14.9 8 316 7 315 165 -1.2 0 -1.2 -1.4 03/05/2006 19:50:00 12.6 1.3 15.3 9.1 12.4 1.3 15.3 9.1 11.8 1.2 14.5 8.8 317 9 302 165 -1.3 0 -1.2 -1.4 03/05/2006 20:00:00 12.4 1.5 15.6 8.4 12.2 1.5 15.6 8.4 12 1.5 15.6 7.6 322 7 325 165 -1.4 0 -1.2 -1.4 03/05/2006 20:10:00 14.3 1.5 17.9 10.7 14.1 1.5 17.9 10.7 13.8 1.6 17.9 9.5 319 7 318 165 -1.4 0 -1.2 -1.4 03/05/2006 20:20:00 14.4 1.4 18.3 10.3 14.3 1.4 17.9 9.9 13.8 1.7 17.6 9.9 317 6 314 165 -1.3 0 -1.2 -1.4 03/05/2006 20:30:00 13.2 1.4 17.2 9.5 13.1 1.4 17.6 9.5 12.2 1.7 17.9 8.4 314 8 318 165 -1.4 0 -1.2 -1.4 03/05/2006 20:40:00 12 1.4 15.3 7.6 11.9 1.3 14.9 7.2 11 1.7 14.9 7.2 311 8 312 165 -1.4 0 -1.2 -1.4 03/05/2006 20:50:00 11.8 1.2 14.5 8.8 11.7 1.2 14.9 8.8 10.1 1.4 13.7 6.8 308 7 299 165 -1.4 0 -1.2 -1.4 03/05/2006 21:00:00 13 1.2 16.4 9.9 12.9 1.2 16.4 9.9 11.9 1.5 16.4 8 311 7 308 165 -1.4 0 -1.4 -1.4 03/05/2006 21:10:00 13.7 1.3 17.2 10.3 13.6 1.3 17.2 10.3 12.3 1.5 16.8 8 311 6 313 165 -1.4 0 -1.2 -1.4 03/05/2006 21:20:00 13.4 1.1 16.1 10.7 13.3 1.2 16.1 10.3 11.9 1.4 15.6 8 310 6 310 165 -1.4 0 -1.2 -1.4 03/05/2006 21:30:00 11.8 1.1 14.9 8.4 11.6 1.1 14.5 8.4 10.8 1.2 14.5 7.2 312 6 310 165 -1.5 0 -1.4 -1.7 03/05/2006 21:40:00 11 1.1 14.1 8.4 11 1.1 14.1 8 9.9 1.4 13.7 6.1 308 7 293 165 -1.4 0 -1.4 -1.7 03/05/2006 21:50:00 10.5 1.3 13.7 6.8 10.4 1.3 13.7 7.2 9.4 1.5 14.5 6.1 309 7 313 165 -1.4 0 -1.4 -1.4 03/05/2006 22:00:00 10.2 1 12.6 7.6 10.1 1.1 13 7.6 8.4 1 11.5 5.7 306 8 302 165 -1.6 0 -1.4 -1.7 03/05/2006 22:10:00 10.7 1.3 14.9 7.6 10.6 1.3 14.9 7.6 9.4 1.3 13 6.5 311 8 304 165 -1.6 0 -1.4 -1.9 03/05/2006 22:20:00 11.6 1.1 14.9 8.8 11.5 1.1 15.3 8.8 9.6 1.1 13.7 6.8 308 6 304 165 -1.6 0 -1.4 -1.7 03/05/2006 22:30:00 13 1.6 17.6 9.5 12.9 1.6 17.2 9.5 11.6 1.7 16.1 7.6 311 6 304 165 -1.5 0 -1.4 -1.7 03/05/2006 22:40:00 12.4 1.2 15.3 8.8 12.3 1.2 15.3 8.8 11 1.7 15.3 6.8 309 7 319 165 -1.5 0 -1.2 -1.9 03/05/2006 22:50:00 11.5 1.1 13.7 8 11.4 1.1 13.7 8.4 10.5 1.3 13.7 5.7 310 7 304 165 -1.5 0 -1.4 -1.7 03/05/2006 23:00:00 12.2 1.7 16.8 8 12.1 1.7 16.8 8 10.8 1.5 14.9 7.2 310 6 307 165 -1.6 0 -1.4 -1.7 03/05/2006 23:10:00 14.1 1.4 18.7 10.3 14 1.5 18.3 10.7 12.5 1.6 17.2 8 310 7 311 165 -1.5 0 -1.4 -1.7 03/05/2006 23:20:00 16.3 1.7 20.2 10.7 16.2 1.7 20.2 11.1 13.2 2 17.9 8 304 6 305 165 -1.4 0 -1.2 -1.4 03/05/2006 23:30:00 16.5 1.5 21 12.6 16.5 1.5 21 12.2 14.4 1.9 19.9 9.9 308 7 302 165 -1.4 0 -1.2 -1.4 03/05/2006 23:40:00 17.6 2 24 13 17.5 2 24 13 15.7 2.5 21.8 9.5 309 7 303 165 -1.3 0 -1.2 -1.4 03/05/2006 23:50:00 20.1 1.9 24 13.7 20 1.9 23.7 14.5 18.1 2 22.9 11.1 308 6 306 165 -1.4 0 -1.2 -1.4 03/06/2006 00:00:00 20.8 1.6 25.2 15.6 20.8 1.7 25.2 16.1 18.6 2.2 24 12.6 307 6 303 165 -1.5 0 -1.4 -1.7 03/06/2006 00:10:00 20.9 1.5 24.4 16.4 20.9 1.5 24.8 16.4 19.2 2.1 24.8 13.3 309 5 310 165 -1.6 0 -1.4 -1.9 03/06/2006 00:20:00 23 1.5 26.8 18.3 22.9 1.6 26.8 18.7 21.4 2.2 27.1 15.3 309 5 296 165 -1.6 0 -1.4 -1.9 03/06/2006 00:30:00 22.3 1.7 26 17.2 22.3 1.7 25.6 16.8 20.9 2.5 25.6 13.3 309 5 307 165 -1.7 0 -1.4 -1.9 03/06/2006 00:40:00 21.5 1.8 27.1 16.8 21.5 1.7 26.8 16.4 19.1 2.2 24 14.1 307 6 302 165 -1.7 0 -1.4 -1.9 03/06/2006 00:50:00 21.1 1.6 26.8 17.2 21 1.6 26.8 17.2 19 2.4 24 13.3 307 5 310 165 -1.9 0 -1.7 -1.9 03/06/2006 01:00:00 20.8 1.6 25.2 16.4 20.7 1.7 24.8 15.6 18.4 2.1 24.4 13 307 6 305 165 -2 0 -1.7 -2.1 03/06/2006 01:10:00 21.3 1.5 24.8 16.1 21.3 1.6 24.8 16.1 19.2 2.3 24 13.3 307 5 303 165 -2 0 -1.9 -2.1 03/06/2006 01:20:00 21.4 1.9 26 16.8 21.4 1.9 26 16.8 18.9 2 24.8 13.3 307 6 300 165 -2 0 -1.9 -2.1 03/06/2006 01:30:00 21.6 1.5 24.4 17.6 21.5 1.5 24.4 17.2 18.7 1.9 24 13.7 306 5 304 165 -2 0 -1.9 -2.1 03/06/2006 01:40:00 21.5 1.6 24.4 17.2 21.5 1.7 24.8 16.8 18.3 2.2 23.3 11.5 305 4 301 165 -2.1 0 -1.9 -2.1 03/06/2006 01:50:00 21.5 1.4 25.6 18.3 21.4 1.4 25.6 17.9 18.3 2 22.9 12.6 305 4 312 165 -2.1 0 -1.9 -2.1 03/06/2006 02:00:00 22.1 1.6 26 17.9 22.1 1.6 26 17.9 20.4 2 25.6 14.1 308 4 313 165 -2.1 0 -1.9 -2.1 03/06/2006 02:10:00 22.2 1.6 26 17.9 22.2 1.7 26 17.6 20.2 2.2 24.8 13 308 4 300 165 -2.1 0 -1.9 -2.1 03/06/2006 02:20:00 21.2 1.7 26 15.6 21.1 1.7 25.6 15.6 19.2 2.6 24.8 13 308 5 307 165 -2 0.1 -1.9 -2.1 03/06/2006 02:30:00 19.9 1.5 22.9 15.6 19.8 1.5 22.9 15.3 16.7 2 21.8 11.8 305 5 299 165 -2 0 -1.9 -2.1 03/06/2006 02:40:00 20.7 1.7 24 16.4 20.6 1.7 24 16.1 17.8 2.2 23.7 11.1 306 5 310 165 -1.8 0 -1.7 -2.1 03/06/2006 02:50:00 19.8 1.5 24 16.1 19.7 1.6 24 15.3 15.6 1.7 20.6 11.5 302 5 298 165 -1.9 0 -1.7 -1.9 03/06/2006 03:00:00 20.1 1.5 23.3 15.6 20.1 1.5 23.3 14.5 17.3 2.1 22.9 11.5 306 5 303 165 -2 0 -1.9 -2.1 03/06/2006 03:10:00 20.4 1.3 23.3 14.5 20.3 1.3 22.9 14.5 17 2 24 11.5 305 4 305 165 -2 0 -1.9 -2.1 03/06/2006 03:20:00 19.9 1.2 22.6 16.1 19.9 1.2 22.6 16.1 16.9 1.7 21.8 12.2 306 4 302 165 -2.1 0 -1.9 -2.4 03/06/2006 03:30:00 18.2 1.7 21.8 14.1 18.1 1.7 21.8 14.1 14.7 2.3 20.6 10.3 304 5 304 165 -2.2 0 -1.9 -2.6 03/06/2006 03:40:00 18.9 1.4 22.6 15.3 18.8 1.4 22.6 14.5 14.7 1.9 19.5 10.3 303 5 301 165 -2.2 0 -2.1 -2.4 03/06/2006 03:50:00 19.1 1.3 22.6 15.6 19 1.3 22.6 15.3 15 1.6 19.1 10.7 303 5 300 165 -2.2 0 -2.1 -2.4 03/06/2006 04:00:00 17.4 1.1 20.6 14.5 17.4 1.2 20.2 14.1 13.8 1.8 19.9 9.5 305 4 298 165 -2.2 0 -2.1 -2.4 03/06/2006 04:10:00 17.3 1.5 20.2 13.7 17.2 1.5 20.2 13.7 13.4 1.7 17.6 9.1 303 5 304 165 -2.2 0 -2.1 -2.6 03/06/2006 04:20:00 16.6 1.2 19.9 14.1 16.7 1.2 19.9 13.3 12.8 1.5 16.4 9.1 297 5 302 165 -2.4 0 -2.1 -2.6 03/06/2006 04:30:00 15.4 0.7 17.9 13.3 15.5 0.7 17.9 13 12.6 1.3 17.2 8.8 291 3 294 165 -2.2 0 -2.1 -2.6 03/06/2006 04:40:00 15 0.8 17.9 13 15.1 0.8 17.9 12.6 12 1.3 15.3 8.8 293 3 294 165 -2.3 0 -2.1 -2.6 03/06/2006 04:50:00 14.3 1.1 16.4 11.1 14.3 1.1 16.4 10.7 10.9 1.6 15.6 7.2 296 5 291 165 -2.3 0 -2.1 -2.6 03/06/2006 05:00:00 14.2 0.9 16.1 11.8 14.1 1 16.1 11.5 10.1 1.1 14.1 7.6 299 4 301 165 -2.5 0 -2.1 -2.6 03/06/2006 05:10:00 14.4 0.7 16.4 12.2 14.4 0.7 16.8 12.2 10.9 1.3 14.9 8 294 4 291 165 -2.5 0 -2.6 -2.6 03/06/2006 05:20:00 15.5 1 18.3 13 15.5 1 17.9 12.6 11 1.3 14.5 8 295 3 295 165 -2.5 0 -2.6 -2.8 03/06/2006 05:30:00 16.8 1 19.1 13.3 16.8 1 18.7 13.3 11.6 1.2 15.3 9.1 299 4 304 165 -2.4 0 -2.1 -2.6 03/06/2006 05:40:00 16.9 0.9 19.1 14.5 16.9 0.9 19.5 14.1 12.1 1.3 15.6 9.1 298 4 305 165 -2.3 0 -2.1 -2.6 03/06/2006 05:50:00 16.5 1 19.1 14.1 16.5 1 19.1 14.5 11.6 1.3 16.8 9.1 300 4 300 165 -2.6 0 -2.4 -2.8 03/06/2006 06:00:00 17.8 1.1 20.6 14.9 17.7 1.1 20.6 14.1 14 1.8 18.7 9.9 305 5 300 165 -2.4 0 -2.1 -2.6 03/06/2006 06:10:00 16.5 1.3 19.1 13.3 16.4 1.3 19.1 13 13.6 1.7 17.6 8.8 306 5 306 165 -2.4 0.1 -2.1 -2.6 03/06/2006 06:20:00 16.2 1.1 18.7 13 16.1 1.1 18.7 13 13.6 1.6 17.6 9.9 307 5 307 165 -2.5 0 -2.6 -2.8 03/06/2006 06:30:00 15.3 1.3 17.9 11.1 15.1 1.4 17.9 11.1 11.9 1.5 17.6 8 305 5 302 165 -2.6 0 -2.6 -2.8 03/06/2006 06:40:00 15.6 1.2 18.3 11.8 15.5 1.3 18.3 11.8 12.5 1.4 16.1 9.1 306 4 301 165 -2.9 0 -2.6 -3 03/06/2006 06:50:00 15.6 1.5 17.9 10.7 15.4 1.5 17.9 10.3 11.9 1.4 16.1 8.8 303 5 306 165 -2.8 0 -2.6 -3 03/06/2006 07:00:00 15.6 1.6 18.3 11.1 15.4 1.6 18.3 11.1 12.4 1.3 15.6 8.8 306 3 307 165 -2.8 0 -2.6 -3 03/06/2006 07:10:00 11.9 1.3 14.9 8 11.7 1.2 14.1 7.6 9.7 1.4 13 5.7 307 6 304 165 -3.2 0 -2.8 -3.5 03/06/2006 07:20:00 12.9 1.1 15.6 9.9 12.7 1.1 15.6 9.5 10.7 1.3 13.7 6.8 307 5 308 165 -3 0 -2.8 -3.3 03/06/2006 07:30:00 14.1 0.7 15.6 11.8 14 0.8 16.1 11.5 12.6 1 14.9 9.9 310 3 303 165 -2.9 0 -2.8 -3 03/06/2006 07:40:00 14.7 0.7 16.4 12.2 14.7 0.7 16.4 12.2 13.2 0.9 15.3 10.3 310 3 307 165 -2.9 0.1 -2.8 -3 03/06/2006 07:50:00 14.7 0.6 16.1 13 14.6 0.6 16.1 13 13.8 0.8 15.3 11.1 312 3 315 165 -3 0 -2.8 -3.3 03/06/2006 08:00:00 14.3 0.7 15.6 11.8 14.2 0.7 15.6 11.5 13.5 0.8 14.9 9.9 312 3 310 165 -2.8 0.1 -2.6 -3 03/06/2006 08:10:00 14.4 0.6 16.1 12.2 14.3 0.7 16.1 12.2 13 1 15.3 9.5 310 3 314 165 -2.6 0 -2.4 -2.8 03/06/2006 08:20:00 14.4 0.8 16.1 11.8 14.2 0.9 16.4 11.5 12.6 1.1 15.3 9.5 310 4 306 165 -2.5 0 -2.4 -2.8 03/06/2006 08:30:00 11.4 1.5 14.9 7.6 11.3 1.4 14.5 8 10.5 1.7 13.7 6.8 317 8 316 165 -2.5 0 -2.1 -2.6 03/06/2006 08:40:00 8.5 1.5 11.8 4.6 8.4 1.5 11.5 4.2 7.4 1.7 11.5 3 314 10 315 165 -2.1 0 -1.7 -2.4 03/06/2006 08:50:00 9.5 1.2 11.8 6.1 9.4 1.2 11.8 6.5 7.8 1.3 11.1 4.9 306 9 300 165 -1.9 0.1 -1.7 -2.1 03/06/2006 09:00:00 9.1 1.7 13 4.2 9 1.7 12.6 3.8 7.9 1.7 12.2 3 310 9 311 165 -2 0 -1.7 -2.1 03/06/2006 09:10:00 9.7 1.9 14.1 6.5 9.7 1.9 13.7 6.1 7.8 1.5 11.8 4.2 303 7 304 165 -1.7 0.1 -1.2 -1.9 03/06/2006 09:20:00 9.9 1.6 16.1 6.8 9.9 1.6 15.6 6.8 8 1.7 14.9 5.3 298 8 292 165 -1.3 0.1 -1 -1.4 03/06/2006 09:30:00 9.1 1.1 12.2 6.1 9.1 1.1 11.8 6.5 8 1.5 12.2 4.9 289 7 283 165 -1.3 0 -1.2 -1.4 03/06/2006 09:40:00 9.2 1.2 13.3 6.5 9.1 1.2 13.7 6.1 7.1 1 10.3 4.6 301 6 290 165 -1.3 0 -1 -1.7 03/06/2006 09:50:00 9.3 1.1 12.6 5.3 9.2 1.1 12.6 5.3 7.5 1 11.5 4.9 304 7 310 165 -1 0.1 -0.8 -1.2 03/06/2006 10:00:00 7.1 1.4 11.5 4.6 7 1.5 11.5 4.2 6.3 1.2 10.7 4.2 312 11 295 165 -0.7 0.2 -0.1 -1.2 03/06/2006 10:10:00 7.7 0.7 9.9 5.3 7.6 0.8 9.9 4.9 6.4 1 8.8 4.2 309 7 310 165 -0.9 0 -0.8 -1.2 03/06/2006 10:20:00 7.1 0.6 8.8 5.3 7.1 0.7 8.8 4.9 6.1 0.9 8 3.4 307 7 314 165 -1.1 0 -0.8 -1.2 03/06/2006 10:30:00 6.1 0.5 7.6 4.6 6 0.6 7.6 4.9 5.2 0.7 7.6 3.4 306 7 302 165 -0.9 0.1 -0.5 -1.2 03/06/2006 10:40:00 5.7 0.8 8.4 3.8 5.6 0.8 8 3.8 4.8 0.8 6.8 3 305 8 305 165 -0.7 0 -0.5 -1 03/06/2006 10:50:00 4.5 0.7 7.2 2.6 4.5 0.7 7.6 2.6 4.1 0.7 6.5 2.6 293 10 288 165 -0.8 0.1 -0.5 -1 03/06/2006 11:00:00 4.8 0.9 6.5 2.6 5.2 0.9 6.8 3 4.9 0.9 6.5 3 275 7 268 165 -0.6 0 -0.3 -0.8 03/06/2006 11:10:00 5.2 0.8 6.8 3 5.4 0.6 6.8 3.8 5.1 0.8 6.8 3 278 8 283 165 -0.6 0 -0.3 -0.8 03/06/2006 11:20:00 3.7 0.6 5.7 2.3 4.2 0.6 6.1 2.3 4 0.6 5.3 2.3 267 9 265 165 -0.1 0.1 0.2 -0.5 03/06/2006 11:30:00 5.7 1.2 8.4 2.3 5.8 1.1 8.4 2.3 5.3 1.2 8.8 2.3 285 10 281 165 -0.3 0.1 0.2 -0.5 03/06/2006 11:40:00 5.2 1 7.6 3 5.5 0.9 7.6 3.4 5.2 0.9 7.2 2.6 276 8 282 165 -0.6 0 -0.5 -0.8 03/06/2006 11:50:00 5.5 0.7 7.2 3.4 5.7 0.7 6.8 4.2 5.6 0.7 7.2 3.8 274 6 282 165 -0.5 0.1 -0.1 -0.8 03/06/2006 12:00:00 4.6 0.7 6.5 2.6 4.7 0.6 6.8 2.6 4.4 0.9 6.8 2.6 285 17 277 165 -0.3 0 -0.1 -0.5 03/06/2006 12:10:00 4.8 0.6 6.5 3.4 4.7 0.6 6.1 3.4 3.9 0.7 5.7 2.3 305 7 310 165 -0.4 0 -0.1 -0.8 03/06/2006 12:20:00 4.2 0.7 5.7 2.3 4.2 0.6 5.7 2.3 3.5 0.5 4.9 2.3 293 13 302 165 -0.5 0 -0.3 -0.8 03/06/2006 12:30:00 4.5 0.6 6.1 2.6 4.7 0.7 6.1 3 4.4 0.8 5.7 2.3 277 9 267 165 -0.7 0.1 -0.3 -0.8 03/06/2006 12:40:00 5.5 0.8 7.2 3.8 5.5 0.7 7.2 3.8 5 0.9 7.2 2.6 305 12 314 165 -0.5 0 -0.3 -0.8 03/06/2006 12:50:00 5.4 0.6 6.8 3.4 5.3 0.6 6.8 3.4 4.8 0.6 6.5 3 309 7 306 165 -0.5 0 -0.3 -0.5 03/06/2006 13:00:00 4.8 0.6 6.1 3 4.7 0.6 6.5 3 4.2 0.8 6.1 2.3 308 9 296 165 -0.3 0 -0.1 -0.5 03/06/2006 13:10:00 5.1 0.6 6.5 3.8 5.1 0.6 6.5 3.4 4.1 0.6 5.7 2.6 304 7 310 165 -0.3 0 -0.3 -0.5 03/06/2006 13:20:00 6.2 0.8 8.8 4.6 6.2 0.8 8.4 4.2 5.1 0.9 8 3 300 9 309 165 -0.9 0.1 -0.5 -1.2 03/06/2006 13:30:00 5.9 0.6 7.2 4.2 5.9 0.6 6.8 3.8 5.2 0.6 6.8 3.4 309 5 298 165 -0.7 0.1 -0.3 -1 03/06/2006 13:40:00 5.1 0.8 6.8 3.4 5.1 0.8 6.8 3.4 4.6 0.9 6.8 1.9 308 8 297 165 -0.3 0.1 0.2 -0.5 03/06/2006 13:50:00 4.4 0.5 5.7 2.6 4.4 0.5 5.7 2.6 4.2 0.6 5.3 3 315 8 300 165 0.2 0.1 0.4 -0.1 03/06/2006 14:00:00 4.1 0.4 5.3 3 4 0.5 5.3 3 3.7 0.4 4.9 2.6 313 8 308 165 0.2 0.1 0.7 -0.1 03/06/2006 14:10:00 4.3 0.5 5.3 3 4.2 0.5 5.3 3 4.3 0.5 5.3 3 318 7 308 165 0.4 0 0.7 0.2 03/06/2006 14:20:00 4 0.5 5.3 2.6 4 0.5 5.3 2.6 3.7 0.6 5.3 2.6 313 8 315 165 0.5 0.2 0.9 0.2 03/06/2006 14:30:00 3.7 0.7 5.3 2.3 3.7 0.7 5.3 2.3 3.1 0.6 4.6 1.5 295 9 307 165 0.2 0 0.7 -0.1 03/06/2006 14:40:00 3.4 0.5 4.6 2.3 3.5 0.5 4.6 2.3 2.9 0.5 4.2 1.9 296 8 296 165 0 0.2 0.7 -0.3 03/06/2006 14:50:00 3.5 0.5 4.9 2.3 3.5 0.5 4.9 2.3 3.2 0.5 4.9 1.9 308 11 289 165 0.9 0.3 1.4 0.7 03/06/2006 15:00:00 4 0.5 5.3 2.6 4 0.5 4.9 2.6 3.4 0.6 4.9 2.3 306 7 310 165 0.7 0.2 1.4 0.2 03/06/2006 15:10:00 3.7 0.6 5.3 2.3 3.8 0.6 5.3 2.3 3 0.6 4.9 1.5 300 8 297 165 0.6 0.2 0.9 0.2 03/06/2006 15:20:00 3.5 0.6 4.6 1.9 3.5 0.6 4.6 1.5 2.9 0.4 4.6 1.9 302 9 301 165 0.4 0.1 0.9 0.2 03/06/2006 15:30:00 3.4 0.6 4.9 1.9 3.4 0.6 4.6 1.9 2.8 0.5 4.6 1.5 301 9 296 165 0.5 0.4 1.4 -0.1 03/06/2006 15:40:00 2.4 0.5 3.4 1.1 2.3 0.5 3.4 1.1 1.9 0.5 3.4 0.7 296 9 285 165 -0.1 0.1 0.2 -0.3 03/06/2006 15:50:00 1.9 0.4 2.6 1.1 1.9 0.4 2.6 1.1 1.6 0.4 2.6 0.7 288 7 296 165 -0.1 0 0.2 -0.3 03/06/2006 16:00:00 1.9 0.5 3.4 0.7 1.9 0.5 3.4 0.7 1.5 0.5 3 0.4 296 10 297 165 0.7 0.4 1.4 -0.1 03/06/2006 16:10:00 2.3 0.4 3.4 1.5 2.4 0.3 3 1.5 2.3 0.4 3 1.1 282 8 287 165 0.7 0.3 1.4 0.2 03/06/2006 16:20:00 1.7 0.5 3.4 0.7 1.9 0.5 3.4 0.7 1.8 0.6 3 0.4 221 47 125 165 0.2 0 0.7 0.2 03/06/2006 16:30:00 2.7 0.4 3.8 1.5 2.7 0.4 3.8 1.5 2.7 0.4 3.8 1.5 139 13 143 165 0.1 0.2 0.7 -0.1 03/06/2006 16:40:00 3.1 0.4 4.2 1.9 3.2 0.4 4.2 1.9 3.1 0.5 4.2 1.9 136 6 130 165 -0.3 0 -0.1 -0.5 03/06/2006 16:50:00 2.4 0.6 3.8 0.4 2.4 0.6 4.2 0.7 2.3 0.6 3.8 0.4 168 27 132 165 -0.4 0 -0.3 -0.5 03/06/2006 17:00:00 3.3 0.5 4.6 2.3 3.3 0.5 4.6 2.3 3.3 0.6 4.9 2.3 158 12 161 165 -0.6 0 -0.3 -0.8 03/06/2006 17:10:00 3.7 0.6 5.7 1.5 3.7 0.6 5.7 1.9 3.7 0.5 4.9 2.6 152 12 154 165 -0.8 0 -0.5 -0.8 03/06/2006 17:20:00 2.6 0.6 4.2 0.4 2.6 0.6 4.2 0.4 2.5 0.6 4.6 1.1 159 16 155 165 -0.8 0 -0.5 -0.8 03/06/2006 17:30:00 1.8 0.9 3.4 0.4 2 0.9 3.8 0.4 1.8 0.9 3.4 0.4 138 15 137 165 -0.8 0 -0.5 -0.8 03/06/2006 17:40:00 0.9 0.5 2.3 0.4 1 0.5 2.6 0.4 0.8 0.4 2.3 0.4 95 30 94 165 -0.9 0 -0.8 -1 03/06/2006 17:50:00 1.6 0.9 3 0.4 1.7 0.9 3 0.4 1.7 0.9 3 0.4 66 38 40 165 -1.1 0.2 -0.8 -1.4 03/06/2006 18:00:00 2.4 0.3 3.4 1.5 2.5 0.3 3.4 1.5 2.6 0.3 3.4 1.9 54 7 52 165 -1.5 0 -1.2 -1.7 03/06/2006 18:10:00 2.6 0.4 3.4 1.5 2.8 0.4 3.8 1.9 2.8 0.4 3.8 1.9 63 8 83 165 -1.7 0 -1.4 -1.7 03/06/2006 18:20:00 3.2 0.3 3.8 2.6 3.3 0.3 3.8 2.6 3.3 0.2 4.2 2.6 53 3 48 165 -1.7 0 -1.4 -1.9 03/06/2006 18:30:00 3 0.2 3.4 2.6 3.2 0.2 3.8 2.6 3.2 0.2 3.8 2.6 51 2 47 165 -1.8 0 -1.7 -1.9 03/06/2006 18:40:00 2.5 0.3 3.4 1.5 2.7 0.3 3.4 1.5 2.8 0.3 3.4 2.3 49 6 47 165 -1.8 0 -1.7 -1.9 03/06/2006 18:50:00 2.2 0.2 3 1.9 2.4 0.2 3 1.9 2.4 0.2 3 1.9 42 4 43 165 -1.9 0 -1.7 -1.9 03/06/2006 19:00:00 1.6 0.3 2.3 1.1 1.7 0.3 2.6 1.1 1.9 0.2 2.6 1.5 36 2 34 165 -1.9 0 -1.9 -2.1 03/06/2006 19:10:00 1.6 0.3 2.3 1.1 1.7 0.3 2.3 1.1 2 0.3 2.6 1.5 26 3 25 165 -1.9 0 -1.9 -1.9 03/06/2006 19:20:00 1.8 0.3 2.3 1.1 1.9 0.3 2.6 1.1 2.2 0.3 2.6 1.9 21 2 25 165 -1.9 0 -1.7 -1.9 03/06/2006 19:30:00 1.3 0.3 1.9 0.7 1.5 0.4 2.3 0.7 1.8 0.3 2.6 1.1 22 3 23 165 -1.9 0 -1.9 -1.9 03/06/2006 19:40:00 1.5 0.3 2.3 0.7 1.5 0.3 2.3 0.7 2 0.4 2.6 1.5 19 0 19 165 -2 0 -1.9 -1.9 03/06/2006 19:50:00 2.7 0.2 3.4 1.9 2.6 0.3 3.4 1.9 3 0.2 3.4 2.3 21 2 26 165 -2 0 -1.9 -2.1 03/06/2006 20:00:00 2.9 0.3 3.4 2.3 2.5 0.4 3.4 1.1 3.3 0.2 3.8 2.6 16 4 14 165 -2 0 -1.9 -2.1 03/06/2006 20:10:00 2.7 0.2 3 2.3 2.1 0.4 3 1.1 3.1 0.2 3.4 2.6 13 2 18 165 -2.1 0 -1.9 -2.1 03/06/2006 20:20:00 3.1 0.3 3.8 2.3 2 0.5 3.4 1.1 3.4 0.3 4.2 2.6 7 4 12 165 -2.1 0 -2.1 -2.1 03/06/2006 20:30:00 2.8 0.3 3.8 2.3 1.8 0.4 3 0.7 3.1 0.3 3.8 2.3 357 3 1 165 -2.2 0 -2.1 -2.4 03/06/2006 20:40:00 2.8 0.3 3.4 2.3 2.7 0.4 3.8 1.5 3.1 0.3 3.8 2.6 348 4 354 165 -2.2 0 -2.1 -2.4 03/06/2006 20:50:00 3.1 0.3 3.8 2.3 2.8 0.5 4.2 1.1 3.3 0.3 3.8 2.6 349 5 347 165 -2.3 0 -2.1 -2.6 03/06/2006 21:00:00 2.5 0.4 3.4 1.5 2.5 0.4 3.4 1.1 2.6 0.4 3.4 1.9 339 9 334 165 -2.3 0 -2.1 -2.6 03/06/2006 21:10:00 3.4 0.6 5.3 2.3 3.2 0.8 5.3 1.1 3.5 0.6 5.3 2.6 348 6 349 165 -2.2 0 -2.1 -2.6 03/06/2006 21:20:00 3.6 0.3 4.6 3 3.5 0.6 4.9 1.5 3.8 0.3 4.6 3 348 4 348 165 -2.3 0 -2.1 -2.6 03/06/2006 21:30:00 3.7 0.5 5.3 2.6 3 0.9 5.7 0.7 3.8 0.5 5.7 2.6 353 6 344 165 -2.2 0 -2.1 -2.6 03/06/2006 21:40:00 4.3 0.4 5.3 3.4 3.5 0.8 5.7 1.5 4.4 0.4 5.3 3 352 6 344 165 -2.2 0 -2.1 -2.4 03/06/2006 21:50:00 4.3 0.5 5.7 3 3.7 0.6 5.3 1.9 4.4 0.5 5.7 3.4 350 5 350 165 -2.3 0 -2.1 -2.6 03/06/2006 22:00:00 4.1 0.4 5.3 3 3.8 0.8 5.7 1.5 4.3 0.4 5.3 3.4 349 5 349 165 -2.3 0 -2.1 -2.4 03/06/2006 22:10:00 4 0.4 4.9 3 3.4 0.7 4.9 1.9 4.3 0.4 5.3 3.4 350 6 353 165 -2.3 0 -2.1 -2.4 03/06/2006 22:20:00 3.8 0.4 4.9 2.6 3.5 0.8 5.3 1.5 4.1 0.3 4.9 3 349 6 346 165 -2.3 0 -2.1 -2.6 03/06/2006 22:30:00 4.1 0.5 5.3 3 3.9 0.8 5.7 1.5 4.3 0.4 5.7 3.4 347 6 346 165 -2.4 0 -2.1 -2.6 03/06/2006 22:40:00 4.1 0.4 5.3 3 4 0.7 5.7 1.5 4.3 0.4 5.3 3.4 347 6 340 165 -2.4 0 -2.1 -2.6 03/06/2006 22:50:00 4.6 0.5 5.7 3.4 3.6 1 6.1 1.9 4.8 0.5 6.1 3.8 353 5 353 165 -2.3 0 -2.1 -2.6 03/06/2006 23:00:00 5.1 0.6 6.8 3.8 4.6 1.2 6.8 1.9 5.2 0.6 7.2 4.2 348 7 355 165 -2.3 0 -2.1 -2.4 03/06/2006 23:10:00 4.8 0.6 6.1 3.8 3.5 1 6.1 1.5 4.9 0.5 6.1 3.8 356 7 354 165 -2.3 0 -2.1 -2.6 03/06/2006 23:20:00 4.6 0.5 6.1 3.4 3.9 1 6.5 1.9 4.8 0.5 6.1 3.8 351 7 340 165 -2.3 0 -2.1 -2.4 03/06/2006 23:30:00 5 0.5 6.8 3.8 4.6 0.8 6.8 2.6 5.2 0.5 7.2 4.2 349 5 350 165 -2.2 0 -2.1 -2.4 03/06/2006 23:40:00 5.4 0.5 6.5 3.8 5 0.8 6.8 2.6 5.5 0.5 6.8 4.2 348 6 349 165 -2.2 0 -2.1 -2.4 03/06/2006 23:50:00 5.5 0.6 7.2 4.2 5.4 0.7 7.2 3 5.6 0.5 7.2 4.6 346 6 353 165 -2.1 0 -2.1 -2.1 03/07/2006 00:00:00 4.5 0.6 6.1 3.4 3.9 0.9 6.1 1.5 4.7 0.5 6.5 3.4 351 6 346 165 -2.2 0 -2.1 -2.4 03/07/2006 00:10:00 5.2 0.6 7.2 3.8 4.8 1.1 7.6 2.3 5.2 0.6 6.8 3.8 348 7 341 165 -2.3 0 -2.1 -2.6 03/07/2006 00:20:00 5.4 0.7 7.6 3.8 5.1 1.1 7.6 1.9 5.5 0.8 7.6 3.8 347 6 349 165 -2.2 0 -2.1 -2.4 03/07/2006 00:30:00 5.7 0.8 7.6 3.8 5.5 1 8 2.6 5.9 0.8 8 4.2 346 7 349 165 -2.2 0 -2.1 -2.6 03/07/2006 00:40:00 5.5 0.9 7.6 3.4 4.8 1.2 7.6 2.3 5.6 0.9 7.6 3.8 350 8 349 165 -2.3 0 -2.1 -2.6 03/07/2006 00:50:00 6.8 1.4 9.5 4.6 6.1 2.3 9.9 2.3 6.7 1.2 9.1 4.6 350 9 349 165 -2.4 0 -2.1 -2.6 03/07/2006 01:00:00 7.7 0.9 9.5 5.7 7.6 1 9.5 3.8 7.6 0.9 9.9 5.7 341 7 339 165 -2.4 0 -2.1 -2.6 03/07/2006 01:10:00 7.6 0.8 10.3 4.9 7.4 1.2 11.1 4.2 7.7 0.8 10.3 5.3 344 7 347 165 -2.4 0 -2.1 -2.6 03/07/2006 01:20:00 7.7 1 10.3 4.9 7.2 1.2 9.9 3.8 7.8 1 10.3 5.3 346 8 357 165 -2.4 0 -2.1 -2.6 03/07/2006 01:30:00 7.8 0.8 9.9 6.1 7.6 1.2 10.7 4.2 7.8 0.8 10.7 5.3 344 7 339 165 -2.5 0 -2.1 -2.6 03/07/2006 01:40:00 9 0.8 10.7 6.8 8.8 1.2 11.1 5.3 9 0.8 11.1 6.1 346 6 343 165 -2.5 0 -2.4 -2.6 03/07/2006 01:50:00 8.8 0.9 10.7 6.5 8.9 1 11.5 6.1 8.9 0.8 11.5 6.8 342 6 347 165 -2.5 0 -2.6 -2.8 03/07/2006 02:00:00 9.4 0.8 11.5 7.2 9.6 1 11.8 7.6 9.4 0.9 11.8 7.2 340 6 349 165 -2.6 0 -2.6 -2.8 03/07/2006 02:10:00 8.4 0.9 10.3 6.1 8.1 1.3 11.1 4.2 8.6 1 11.1 6.5 344 9 352 165 -2.6 0 -2.6 -2.8 03/07/2006 02:20:00 8.6 0.8 10.7 6.1 8.5 1.1 11.1 4.2 8.8 0.9 11.1 6.1 342 7 343 165 -2.7 0 -2.6 -2.8 03/07/2006 02:30:00 9 1 12.2 6.8 9 1.1 12.6 5.3 9.1 1.1 12.2 6.8 342 8 340 165 -2.5 0 -2.6 -2.6 03/07/2006 02:40:00 9.5 1 11.8 6.5 9.5 1.1 11.8 6.1 9.3 1 11.8 6.5 339 8 338 165 -2.5 0 -2.6 -2.8 03/07/2006 02:50:00 9.1 1.1 12.6 6.5 8.8 1.3 12.2 3.8 8.9 1.1 11.8 6.5 342 9 336 165 -2.5 0 -2.6 -2.6 03/07/2006 03:00:00 9.6 1 12.2 6.5 9.6 1.2 12.6 5.7 9.4 1 11.5 6.1 341 8 349 165 -2.6 0 -2.6 -2.8 03/07/2006 03:10:00 10.2 0.7 12.2 8 10.3 1 13.3 6.5 10 1 12.6 7.6 342 6 338 165 -2.6 0 -2.6 -2.8 03/07/2006 03:20:00 9.7 0.9 11.8 7.6 9.8 1 12.2 6.8 9.6 0.9 11.8 6.8 342 6 351 165 -2.6 0 -2.6 -2.8 03/07/2006 03:30:00 9.2 1 11.8 5.7 9.1 1.3 12.2 4.2 8.9 1.1 11.1 4.9 342 6 338 165 -2.6 0 -2.6 -2.8 03/07/2006 03:40:00 8.7 1 11.1 6.1 8.2 1.6 11.1 4.2 8.5 0.9 10.7 6.5 346 8 345 165 -2.6 0 -2.6 -2.8 03/07/2006 03:50:00 8 1 9.9 5.3 7.6 1.6 10.3 3 7.6 1 9.9 4.9 346 7 343 165 -2.6 0 -2.6 -2.8 03/07/2006 04:00:00 8.4 1.4 11.5 5.7 7.6 2 11.5 3 8.3 1.5 12.2 5.3 349 8 354 165 -2.8 0 -2.6 -2.8 03/07/2006 04:10:00 8.7 1 11.1 6.1 8.5 1.8 11.5 3 8.7 1.1 11.1 6.1 346 7 341 165 -2.8 0 -2.6 -2.8 03/07/2006 04:20:00 8.7 1.3 11.8 6.5 8.3 1.8 12.2 3.4 8.6 1.1 11.5 6.1 346 9 344 165 -2.8 0 -2.6 -2.8 03/07/2006 04:30:00 8.3 1 11.1 5.3 8.1 1.5 11.1 4.2 8.1 1.1 10.7 4.9 342 8 344 165 -2.9 0 -2.8 -3 03/07/2006 04:40:00 8.1 1 11.1 5.3 7.8 1.5 11.1 3.4 8.1 1 11.1 4.9 342 11 334 165 -3 0 -2.8 -3 03/07/2006 04:50:00 8.8 1 11.5 6.5 8.2 1.5 11.5 4.2 8.8 1.1 11.8 6.1 345 9 355 165 -3 0 -2.8 -3 03/07/2006 05:00:00 9.5 1 12.2 7.2 9.1 1.4 13 5.3 9.1 1 11.8 6.5 345 8 348 165 -3 0 -2.8 -3 03/07/2006 05:10:00 9.2 1.2 13 6.1 8.9 1.5 12.2 4.6 9 1.1 11.8 6.5 344 8 354 165 -2.9 0 -2.8 -3 03/07/2006 05:20:00 8.9 1.2 13 4.9 8.6 1.7 13.3 3.4 8.5 1.2 12.2 4.6 345 8 349 165 -2.9 0 -2.8 -3 03/07/2006 05:30:00 8.6 1.4 12.2 4.9 8.2 1.7 12.2 4.2 8.3 1.3 11.8 5.3 344 8 334 165 -3 0 -2.8 -3 03/07/2006 05:40:00 8.6 1 10.7 6.1 7.9 1.7 11.5 4.2 8.3 1 11.1 5.7 348 8 340 165 -3 0 -2.8 -3 03/07/2006 05:50:00 7.9 1.3 10.3 3.8 7.7 1.5 10.7 3 7.5 1.3 10.3 3.8 342 9 356 165 -3 0 -2.8 -3.3 03/07/2006 06:00:00 7 1.7 11.5 1.9 6.7 1.8 11.8 2.3 6.6 1.5 11.1 2.6 338 15 345 165 -3 0 -2.8 -3 03/07/2006 06:10:00 8 1.5 11.5 3.8 7.9 1.6 12.2 2.6 7.6 1.5 11.8 4.2 343 8 343 165 -3 0 -2.8 -3 03/07/2006 06:20:00 6.8 1 9.9 3.4 6.7 1.1 9.1 3.4 6.3 1.1 9.1 3 341 9 321 165 -3.1 0 -3 -3.3 03/07/2006 06:30:00 5.4 1.2 8.4 1.9 4.9 1.5 8.8 1.5 4.7 1.3 7.6 0.4 344 15 339 165 -3.2 0 -3 -3.5 03/07/2006 06:40:00 5.7 1.2 9.1 2.6 5.4 1.4 9.1 2.3 4.9 1.2 8 1.9 344 12 350 165 -3.3 0 -3.3 -3.5 03/07/2006 06:50:00 7.2 1.6 11.5 3.4 7.1 1.6 11.8 3.4 6.5 1.6 9.9 3 338 9 322 165 -3.3 0 -3.3 -3.3 03/07/2006 07:00:00 8 1.2 10.7 4.6 8 1.2 11.1 3.8 7.3 1.3 10.3 4.2 338 9 353 165 -3.4 0 -3.3 -3.5 03/07/2006 07:10:00 9.9 1.4 13.3 5.3 9.8 1.5 13.7 5.3 9.1 1.7 13 5.3 337 8 330 165 -3.5 0 -3.3 -3.5 03/07/2006 07:20:00 9.5 1.2 12.6 5.7 9.4 1.3 12.6 5.7 9.1 1.3 12.6 5.7 335 8 329 165 -3.6 0 -3.5 -3.5 03/07/2006 07:30:00 9.3 1.9 14.9 3.8 8.9 2.1 14.9 4.2 8.7 1.8 13 4.2 338 15 333 165 -3.6 0 -3.3 -3.5 03/07/2006 07:40:00 9.6 1.7 14.1 4.9 9.2 2 13.3 4.2 9.1 1.7 14.5 5.3 342 11 3 165 -3.6 0 -3.5 -3.5 03/07/2006 07:50:00 10.4 1.7 14.5 5.7 9.6 1.9 14.5 4.9 10 1.9 14.9 5.3 344 12 348 165 -3.5 0 -3.3 -3.5 03/07/2006 08:00:00 8.5 1.6 12.2 4.6 7.8 1.5 12.2 4.6 8.3 1.6 12.2 4.6 343 15 351 165 -3.5 0 -3.3 -3.5 03/07/2006 08:10:00 8.2 1.4 12.6 4.6 8.1 1.4 12.6 4.2 7.6 1.2 10.7 4.6 327 13 297 165 -3.6 0 -3.5 -3.5 03/07/2006 08:20:00 10.7 1 13.3 8.4 10.5 1 13 8 9.4 1.1 12.2 6.5 310 6 307 165 -3.6 0 -3.5 -3.7 03/07/2006 08:30:00 10.8 0.9 13 7.6 10.7 0.9 13 8 9.2 1.3 13 6.5 310 5 312 165 -3.8 0 -3.5 -3.9 03/07/2006 08:40:00 12.4 1.3 15.6 9.9 12.3 1.3 15.6 9.9 10.5 1.5 14.5 7.2 308 6 307 165 -3.9 0 -3.7 -4.2 03/07/2006 08:50:00 13.2 1 16.8 10.7 13.1 1.1 16.8 10.7 11.9 1.3 16.4 8.8 311 5 322 165 -4 0 -3.9 -4.2 03/07/2006 09:00:00 13.4 1.2 16.4 10.3 13.3 1.2 16.8 9.9 12.1 1.2 14.9 8.8 311 5 291 165 -4.1 0 -3.9 -4.4 03/07/2006 09:10:00 13.7 1.3 16.4 9.9 13.6 1.3 16.4 10.3 12.4 1.5 15.6 8 311 6 311 165 -4 0 -3.9 -4.2 03/07/2006 09:20:00 14.5 1.5 18.3 9.5 14.4 1.5 18.3 9.5 12.8 1.7 17.2 7.2 310 5 315 165 -3.9 0 -3.7 -4.2 03/07/2006 09:30:00 15.3 1.3 17.9 9.9 15.2 1.3 17.6 10.3 13.2 1.7 16.4 8.8 310 5 308 165 -3.9 0 -3.7 -3.9 03/07/2006 09:40:00 15.3 1 17.6 12.2 15.2 1 17.6 12.2 12.8 1.5 16.1 8.8 308 5 304 165 -3.9 0 -3.9 -4.2 03/07/2006 09:50:00 16.6 1.1 19.1 13.3 16.6 1.1 19.1 13.3 13.7 1.5 17.6 9.1 308 4 304 165 -4.1 0 -3.9 -4.2 03/07/2006 10:00:00 16.2 1 18.7 13.7 16.2 1 18.3 13.3 14.1 1.6 17.9 10.3 309 5 309 165 -4.1 0 -3.9 -4.2 03/07/2006 10:10:00 16.7 1.2 20.2 13 16.6 1.3 20.2 13.3 13.8 1.7 18.7 9.5 308 4 308 165 -4.1 0 -3.9 -4.2 03/07/2006 10:20:00 17.2 1.2 20.2 13.7 17.2 1.2 19.9 13.3 14 1.7 18.3 9.5 305 5 304 165 -4.2 0 -3.9 -4.4 03/07/2006 10:30:00 17.9 1.3 20.6 14.5 17.9 1.3 20.6 14.1 14.1 1.5 18.3 9.9 305 5 308 165 -4.2 0 -3.9 -4.4 03/07/2006 10:40:00 18.5 1.2 22.1 15.3 18.5 1.2 22.1 14.5 15.1 1.7 20.6 11.1 306 5 305 165 -4.2 0 -4.2 -4.4 03/07/2006 10:50:00 18.5 1.5 21 14.5 18.4 1.5 21 14.1 16 2 20.6 10.7 308 5 313 165 -4.2 0 -3.9 -4.4 03/07/2006 11:00:00 18.5 1.1 21 15.3 18.5 1.1 21 15.3 16.4 1.5 20.2 12.6 310 4 308 165 -4.2 0 -4.2 -4.4 03/07/2006 11:10:00 18.6 1.3 21 14.1 18.6 1.3 21 14.5 16.7 1.7 20.6 11.8 310 4 313 165 -4.2 0 -3.9 -4.4 03/07/2006 11:20:00 18.7 1.3 21.4 15.3 18.6 1.3 21.4 15.3 17.1 1.4 21 13.7 312 4 307 165 -4.1 0 -3.9 -4.4 03/07/2006 11:30:00 19.4 1 21.4 16.8 19.4 0.9 21.4 16.8 17.4 1.6 21 12.2 310 4 307 165 -3.9 0 -3.7 -4.2 03/07/2006 11:40:00 19.2 0.9 21 16.4 19.1 0.9 21.4 16.1 17.5 1.4 21 12.2 311 4 311 165 -3.7 0.1 -3.5 -3.9 03/07/2006 11:50:00 18.7 1.4 21.4 14.1 18.6 1.4 21.4 14.5 17 1.7 20.6 13 309 5 305 165 -3.6 0 -3.3 -3.7 03/07/2006 12:00:00 18.2 1.7 22.6 13.3 18.2 1.7 22.6 13.3 16.6 2.5 21.8 9.9 310 5 312 165 -3.6 0 -3.3 -3.7 03/07/2006 12:10:00 18.8 1.6 22.1 14.1 18.7 1.7 22.6 13.3 16 2.5 21.4 10.7 306 6 302 165 -3.5 0 -3.3 -3.5 03/07/2006 12:20:00 17.2 1.4 20.6 12.6 17.1 1.5 20.6 11.8 13.8 1.8 18.7 9.5 301 8 289 165 -3.2 0 -2.8 -3.5 03/07/2006 12:30:00 18.6 1.7 22.1 13.7 18.6 1.9 22.9 13.3 14.6 2 20.2 9.9 297 5 290 165 -3.3 0 -3 -3.5 03/07/2006 12:40:00 18.8 1.9 22.6 14.1 18.8 2 22.1 14.1 15.7 2.4 21.4 9.5 305 6 309 165 -3.2 0.1 -3 -3.5 03/07/2006 12:50:00 20.1 1.5 22.9 16.1 20 1.5 22.9 16.1 16.3 2.2 21.4 11.5 305 5 308 165 -3.5 0 -3.3 -3.5 03/07/2006 13:00:00 21.4 1.3 23.7 17.6 21.3 1.3 24 17.2 18.1 1.9 23.3 13.7 306 4 304 165 -3.5 0 -3.3 -3.5 03/07/2006 13:10:00 21.8 1.4 26 18.7 21.8 1.4 26 18.7 19.8 1.7 24.4 14.5 309 4 309 165 -3.4 0 -3.3 -3.5 03/07/2006 13:20:00 22.1 1.7 25.6 16.4 21.9 1.7 25.6 16.1 21.1 1.7 24 15.3 312 6 305 165 -3.4 0 -3 -3.5 03/07/2006 13:30:00 23.2 1.3 26 18.7 23.2 1.3 25.6 18.7 22 1.8 26.3 15.6 310 5 302 165 -3.4 0 -3.3 -3.5 03/07/2006 13:40:00 22.9 1.4 26 18.7 22.9 1.4 25.6 18.7 21.5 1.9 25.6 16.4 310 4 310 165 -3.3 0 -3.3 -3.5 03/07/2006 13:50:00 21.3 2 24.8 13.3 21.2 2 25.2 13.7 20.2 2.1 23.7 13.3 311 6 307 165 -3.2 0 -3 -3.5 03/07/2006 14:00:00 20.7 1.9 24.8 16.4 20.6 1.9 24.8 16.4 19.5 1.9 23.7 14.5 313 7 301 165 -3.3 0 -3 -3.5 03/07/2006 14:10:00 21 1.8 24.8 15.3 20.8 1.9 24.8 15.3 20.5 2.2 25.6 15.6 317 6 313 165 -3.3 0 -3.3 -3.5 03/07/2006 14:20:00 22.6 2 27.5 16.1 22.5 2 27.5 16.4 22.3 2.2 28.7 15.6 319 5 323 165 -3.4 0 -3.3 -3.5 03/07/2006 14:30:00 21.9 2.3 26 15.3 21.7 2.3 26 15.3 21.5 2.5 26.8 14.5 317 6 316 165 -3.4 0.1 -3 -3.5 03/07/2006 14:40:00 21.7 1.6 26.3 17.6 21.5 1.7 26.3 17.6 21.2 1.7 25.6 16.8 318 5 307 165 -3.2 0 -3 -3.5 03/07/2006 14:50:00 21.5 1.7 25.2 16.8 21.4 1.7 25.2 16.1 21 2 26 15.6 319 6 318 165 -3 0 -2.8 -3.3 03/07/2006 15:00:00 20.2 2.3 25.2 14.9 20 2.3 25.2 14.9 19.4 2.6 24.8 11.8 318 6 317 165 -2.9 0 -2.6 -3 03/07/2006 15:10:00 21.6 2.7 26.3 13 21.5 2.6 26.3 12.6 21.2 2.8 27.9 13 319 7 310 165 -3 0 -2.6 -3 03/07/2006 15:20:00 22.2 2 26.8 15.6 22.1 2 27.1 15.6 21.6 2.2 27.5 15.3 317 5 311 165 -3 0.1 -2.8 -3.3 03/07/2006 15:30:00 19.4 2.2 23.7 13 19.3 2.2 23.7 13 18.8 2.4 24.4 11.5 318 9 326 165 -3.1 0 -2.8 -3.3 03/07/2006 15:40:00 19.4 2.3 26 14.1 19.3 2.3 26 14.1 18.4 2.6 24.8 13 316 9 312 165 -3.3 0 -3 -3.5 03/07/2006 15:50:00 17.1 2.4 21.8 10.3 17 2.3 21.4 11.1 15.8 1.9 20.6 11.1 314 8 307 165 -3.2 0.1 -3 -3.5 03/07/2006 16:00:00 14.7 2.2 19.5 9.1 14.6 2.2 19.5 9.5 13.6 2.1 18.3 8.8 315 11 292 165 -2.8 0.1 -2.6 -3.3 03/07/2006 16:10:00 18.3 2.2 23.3 11.8 18.2 2.2 22.9 11.8 17.5 2.2 22.1 11.1 319 7 322 165 -3.2 0.1 -2.8 -3.5 03/07/2006 16:20:00 18.3 2.4 23.7 11.8 18.2 2.3 23.3 11.8 17.4 2.9 24 6.8 322 9 315 165 -3.5 0 -3.3 -3.7 03/07/2006 16:30:00 18.4 1.9 23.3 13.7 18.2 1.9 22.9 13.3 17.6 2 22.1 11.8 320 6 319 165 -3.7 0 -3.3 -3.9 03/07/2006 16:40:00 19.3 1.7 24.4 14.9 19.1 1.7 24.4 14.9 18.9 1.9 24.4 14.1 319 6 319 165 -4 0.1 -3.9 -4.4 03/07/2006 16:50:00 17.8 1.7 22.1 13.3 17.7 1.8 22.1 13.3 17.5 1.8 22.1 12.6 321 9 323 165 -4.2 0 -3.9 -4.4 03/07/2006 17:00:00 18.4 1.6 22.6 13.7 18.4 1.6 22.6 14.1 18.1 1.6 22.6 13.7 318 7 313 165 -4.4 0 -4.4 -4.6 03/07/2006 17:10:00 16.4 2 21 10.3 16.3 2 21 10.3 16.1 2.1 21.8 10.7 320 8 310 165 -4.3 0 -4.2 -4.4 03/07/2006 17:20:00 17.2 2.3 22.9 13 17.1 2.4 22.9 12.6 16.8 2.3 21.8 11.1 317 7 305 165 -4.4 0 -4.2 -4.6 03/07/2006 17:30:00 15.4 1.7 20.2 10.7 15.3 1.8 20.2 11.5 14.8 1.7 20.2 10.3 317 7 326 165 -4.5 0 -4.4 -4.6 03/07/2006 17:40:00 17.3 1.5 21.8 13.7 17.2 1.6 21.8 13.3 16.4 1.6 20.6 11.8 315 6 309 165 -4.4 0 -4.4 -4.6 03/07/2006 17:50:00 16 1.9 20.6 12.2 15.9 1.9 20.2 11.1 15.3 2 20.2 11.1 317 7 310 165 -4.6 0.1 -4.4 -4.8 03/07/2006 18:00:00 15.1 1.6 18.7 11.1 15 1.6 18.7 11.5 14.4 1.9 19.1 8.4 316 7 317 165 -4.8 0 -4.6 -4.8 03/07/2006 18:10:00 13.4 1.5 16.8 8.4 13.3 1.5 16.8 8.8 11.3 1.5 15.6 8.4 305 8 295 165 -5.2 0.2 -4.8 -5.5 03/07/2006 18:20:00 13.8 1.7 18.7 9.5 13.7 1.7 18.7 9.9 12.5 2.1 18.3 7.6 309 7 309 165 -5.7 0.1 -5.5 -5.9 03/07/2006 18:30:00 13.6 1.5 18.7 9.9 13.5 1.5 18.7 9.9 13 1.8 19.1 8.8 316 8 314 165 -6 0 -5.9 -6.1 03/07/2006 18:40:00 13.8 2.3 19.5 9.1 13.7 2.3 19.1 8.4 11.9 2 16.8 7.6 306 10 297 165 -5.8 0 -5.7 -6.1 03/07/2006 18:50:00 17.5 2.1 21.8 11.8 17.4 2.1 22.1 12.2 14.8 2.4 21.4 10.7 304 8 292 165 -5.8 0 -5.5 -5.7 03/07/2006 19:00:00 18.8 2.3 25.6 14.5 18.7 2.3 26 14.1 16.6 2.4 24 10.3 305 7 305 165 -5.9 0 -5.7 -6.1 03/07/2006 19:10:00 20.1 2.5 24.8 13.3 20.1 2.6 24.8 13 17.8 2.4 24 10.7 304 7 296 165 -6.1 0 -5.9 -6.4 03/07/2006 19:20:00 22.3 2.2 27.5 16.4 22.3 2.2 27.5 16.4 18.9 2 25.2 14.9 302 6 298 165 -6 0 -5.7 -6.1 03/07/2006 19:30:00 23.8 2.2 29.1 17.9 23.8 2.3 29.1 17.6 20.1 2.2 27.9 14.5 300 6 303 165 -6 0 -5.7 -6.1 03/07/2006 19:40:00 21.4 2.1 27.5 16.4 21.3 2.1 27.9 16.1 17.4 2.4 25.6 11.8 300 7 284 165 -6.2 0 -6.1 -6.4 03/07/2006 19:50:00 21.6 1.8 26.8 17.2 21.6 1.9 26.8 16.8 17.4 2.2 25.6 11.8 299 6 293 165 -6.3 0 -6.1 -6.6 03/07/2006 20:00:00 22.3 2.2 27.1 15.3 22.3 2.3 27.5 15.3 17.9 2.9 25.2 12.6 299 7 297 165 -6.4 0 -6.1 -6.6 03/07/2006 20:10:00 21.2 1.9 25.2 16.1 21.2 2 25.6 16.1 16.6 2.3 23.7 11.5 294 6 295 165 -6.5 0 -6.4 -6.8 03/07/2006 20:20:00 19.8 1.8 25.2 14.9 19.8 1.8 24.8 14.9 15.7 2 21.8 10.7 298 6 298 165 -6.6 0 -6.6 -6.8 03/07/2006 20:30:00 20.5 2.5 26.3 13.7 20.5 2.6 26.3 14.1 16.8 2.6 24.4 11.5 299 7 300 165 -6.8 0 -6.6 -6.8 03/07/2006 20:40:00 22.2 1.9 27.9 16.8 22.2 1.9 27.5 17.2 18.3 2.2 25.2 13 299 7 300 165 -6.9 0 -6.8 -7 03/07/2006 20:50:00 23.2 1.9 28.7 18.3 23.3 1.9 28.3 18.3 18.4 2.3 24.8 13 298 6 295 165 -6.8 0 -6.6 -7 03/07/2006 21:00:00 22.1 2.2 27.1 16.1 22.1 2.2 27.1 16.1 17.9 2.4 26 13 298 6 290 165 -6.9 0 -6.8 -7 03/07/2006 21:10:00 23.3 1.8 27.5 17.6 23.3 1.9 27.5 18.3 20.2 2.5 27.1 14.5 301 7 302 165 -7.1 0 -6.8 -7.2 03/07/2006 21:20:00 22.6 2.3 27.9 17.6 22.6 2.4 27.9 17.2 19.3 2.2 26 14.1 300 6 297 165 -7.3 0 -7 -7.4 03/07/2006 21:30:00 22.5 2.1 27.1 16.4 22.4 2.2 27.5 16.8 20 2.6 27.5 14.9 303 7 291 165 -7.4 0 -7.2 -7.6 03/07/2006 21:40:00 22.2 2 26.3 16.1 22.2 2.1 26.3 15.6 19.1 2.1 25.2 13.3 300 7 302 165 -7.5 0 -7.4 -7.6 03/07/2006 21:50:00 22.5 1.9 26.3 14.9 22.5 2 26.3 15.6 18.5 2.2 25.6 13.3 299 5 305 165 -7.4 0 -7.2 -7.6 03/07/2006 22:00:00 21.9 1.7 27.1 17.6 21.9 1.7 26.8 17.6 18.7 2.1 24.4 14.1 301 6 300 165 -7.5 0 -7.2 -7.6 03/07/2006 22:10:00 21.3 2.3 26 14.5 21.3 2.3 26.3 14.1 18 2.5 24 11.5 301 6 306 165 -7.5 0 -7.4 -7.6 03/07/2006 22:20:00 20.7 2.6 27.1 13.7 20.7 2.7 27.1 13.7 17.4 2.3 23.3 10.3 301 7 302 165 -7.5 0 -7.2 -7.6 03/07/2006 22:30:00 21.1 1.7 26 16.8 21 1.7 26.8 17.2 16.9 2.1 22.9 12.6 299 6 292 165 -7.3 0 -7.2 -7.4 03/07/2006 22:40:00 20.5 2.2 26 14.9 20.5 2.2 26 14.1 16.1 2.2 23.3 10.7 299 6 291 165 -7.3 0 -7 -7.4 03/07/2006 22:50:00 18.7 2.4 26 13 18.7 2.4 25.2 12.6 15.3 2.4 22.1 10.3 301 8 298 165 -7.3 0 -7.2 -7.4 03/07/2006 23:00:00 22.3 2.5 27.9 16.1 22.3 2.5 27.9 16.1 18 2.6 24.4 11.5 301 7 291 165 -7.3 0 -6.8 -7.4 03/07/2006 23:10:00 21 2.6 27.1 15.6 21 2.7 27.1 14.9 17 2.7 26 11.8 300 7 300 165 -7.3 0 -7 -7.4 03/07/2006 23:20:00 20.7 2.4 26.3 14.9 20.7 2.5 26.3 14.5 16.8 2.8 27.5 10.7 294 7 278 165 -7.3 0 -7.2 -7.4 03/07/2006 23:30:00 21.4 2.2 27.5 16.1 21.5 2.3 27.9 16.1 17.3 2.6 25.6 12.2 294 7 297 165 -7.3 0 -7.2 -7.4 03/07/2006 23:40:00 20.8 2.1 26.3 14.5 20.8 2.1 26.3 14.1 16.9 2.5 24.4 11.8 294 7 297 165 -7.3 0 -7.2 -7.4 03/07/2006 23:50:00 20.5 2.7 26.3 14.5 20.4 2.7 26.8 15.3 16.9 2.6 24.8 11.1 299 8 292 165 -7.4 0 -7.2 -7.6 03/08/2006 00:00:00 18.5 2.8 28.3 13 18.5 2.8 28.3 12.6 15 2.8 25.2 9.1 299 7 302 165 -7.5 0 -7.2 -7.6 03/08/2006 00:10:00 20.2 2.9 26 11.1 20.2 3.1 26.3 9.9 16.5 3.2 24.4 9.1 300 7 287 165 -7.6 0 -7.4 -7.9 03/08/2006 00:20:00 21.1 2.3 26 12.6 21.2 2.3 26 12.6 16.8 2.3 24.4 11.8 295 6 293 165 -7.7 0 -7.6 -7.9 03/08/2006 00:30:00 19.6 1.8 23.7 14.1 19.6 1.9 24 13.7 16.2 2.1 22.1 11.1 299 8 296 165 -7.9 0 -7.6 -8.1 03/08/2006 00:40:00 21.4 2.3 27.1 16.4 21.3 2.4 27.5 16.1 17.8 2.7 26.8 11.5 300 8 302 165 -8 0 -7.6 -8.1 03/08/2006 00:50:00 20.5 2.1 26.3 14.9 20.4 2.2 26.3 14.5 16.2 2.2 22.6 11.5 297 6 291 165 -8 0 -7.6 -8.1 03/08/2006 01:00:00 21.6 2.5 27.5 14.9 21.7 2.5 27.1 14.9 17.6 2.7 24.8 11.5 297 7 298 165 -8.1 0 -7.9 -8.1 03/08/2006 01:10:00 23.5 2.2 30.2 16.1 23.5 2.3 30.2 16.1 19.8 2.9 29.8 12.6 299 7 295 165 -8.1 0 -8.1 -8.3 03/08/2006 01:20:00 24.5 2.8 30.9 16.8 24.5 2.9 30.9 17.6 21.1 3.5 29.1 13.7 299 7 301 165 -8.2 0 -8.1 -8.3 03/08/2006 01:30:00 24.4 2.7 29.8 17.2 24.4 2.7 29.8 17.2 21.7 3.5 28.7 15.3 299 7 289 165 -8.3 0 -8.1 -8.5 03/08/2006 01:40:00 24 2.5 30.9 17.2 24 2.6 31.3 17.2 21.1 2.8 28.3 14.5 299 6 295 165 -8.5 0 -8.3 -8.5 03/08/2006 01:50:00 23.4 2.7 30.6 15.3 23.4 2.7 30.6 15.6 20.5 2.8 27.5 13.3 300 7 298 165 -8.5 0 -8.3 -8.5 03/08/2006 02:00:00 24.5 2.4 29.1 17.9 24.5 2.4 29.1 17.2 22 2.6 28.3 14.9 302 6 291 165 -8.5 0 -8.3 -8.7 03/08/2006 02:10:00 24.7 2.9 31.3 17.9 24.7 2.9 31.3 17.6 23.1 2.8 30.6 16.1 304 8 288 165 -8.5 0 -8.3 -8.5 03/08/2006 02:20:00 25.9 2.7 34 18.3 25.9 2.8 33.6 18.7 23.7 2.9 32.1 16.8 303 7 292 165 -8.3 0 -8.1 -8.5 03/08/2006 02:30:00 27.2 3.1 35.9 19.9 27.2 3.1 36.3 20.2 24.9 3.5 35.9 16.4 301 7 301 165 -8.1 0 -8.1 -8.3 03/08/2006 02:40:00 29.5 2.6 35.9 23.3 29.5 2.7 36.3 22.9 27.6 2.8 34.8 18.7 302 7 294 165 -8.2 0 -8.1 -8.3 03/08/2006 02:50:00 28.3 2.7 34.8 21.8 28.3 2.7 35.2 21 26.9 2.7 33.2 18.7 306 7 306 165 -8.3 0 -8.1 -8.5 03/08/2006 03:00:00 28.1 2.8 36.3 21.4 28.1 2.8 35.9 21.4 26.8 3.1 35.5 19.9 308 7 304 165 -8.4 0 -8.3 -8.5 03/08/2006 03:10:00 29.6 2.8 37.5 21.8 29.6 2.8 36.3 21.4 28.4 3.3 35.5 20.6 308 7 309 165 -8.4 0 -8.3 -8.5 03/08/2006 03:20:00 29.6 2.2 34.8 22.9 29.6 2.2 34.8 22.6 29.1 2.6 35.2 19.5 311 6 303 165 -8.3 0 -8.1 -8.5 03/08/2006 03:30:00 30.1 2.5 36.7 24.4 30.1 2.5 36.7 24 29.4 2.7 35.9 20.2 309 6 293 165 -8.2 0 -8.1 -8.5 03/08/2006 03:40:00 32 2.8 38.6 25.6 32.1 2.8 39.4 26 31.6 3.2 39.4 22.9 310 6 310 165 -8.2 0 -8.1 -8.3 03/08/2006 03:50:00 33.8 2.5 40.9 26 33.9 2.6 40.5 26.3 33.1 2.8 40.1 25.2 307 6 310 165 -8.1 0 -8.1 -8.3 03/08/2006 04:00:00 33.9 2.3 39.8 27.9 34 2.4 40.1 27.9 33.1 2.7 41.6 25.6 307 6 309 165 -8.2 0 -8.1 -8.3 03/08/2006 04:10:00 31.6 2.6 38.6 24 31.6 2.6 38.6 24 30.1 2.7 37.8 21.4 305 6 301 165 -8.3 0 -8.1 -8.5 03/08/2006 04:20:00 32.7 2.7 39 25.2 32.8 2.8 39.4 25.2 30.9 2.8 38.2 21.4 304 6 304 165 -8.3 0 -8.1 -8.5 03/08/2006 04:30:00 29.6 2.8 37.1 23.3 29.6 2.9 36.7 22.6 27.9 2.9 37.1 20.2 304 7 293 165 -8.4 0 -8.1 -8.5 03/08/2006 04:40:00 30.9 2.7 38.2 24 30.9 2.8 37.8 24 29.9 3.2 37.5 22.9 306 7 303 165 -8.4 0 -8.3 -8.5 03/08/2006 04:50:00 32.2 2.8 40.1 24.4 32.3 2.8 40.9 24.8 31.2 3.2 39 21.4 306 7 300 165 -8.5 0 -8.3 -8.5 03/08/2006 05:00:00 32.5 2.8 39.8 25.2 32.6 2.9 39.4 25.2 31.4 3.2 38.6 21 307 6 308 165 -8.3 0 -8.1 -8.5 03/08/2006 05:10:00 34.3 3.1 42.8 26.8 34.4 3.2 43.6 27.1 33.3 3.3 42.8 25.2 306 6 304 165 -8.3 0 -8.1 -8.5 03/08/2006 05:20:00 36.4 2.5 42.8 29.1 36.6 2.6 43.6 29.1 35.5 2.7 42.8 25.6 307 5 304 165 -8.2 0 -8.1 -8.5 03/08/2006 05:30:00 35.4 2.6 41.6 27.1 35.5 2.7 42.4 27.1 34.8 2.8 40.9 24 308 5 302 165 -8.2 0 -8.1 -8.5 03/08/2006 05:40:00 34 2.6 41.6 26.8 34 2.7 41.3 27.1 33.1 2.7 41.3 26.3 307 6 314 165 -8.1 0 -8.1 -8.3 03/08/2006 05:50:00 32 3.1 38.2 24.4 32.1 3.2 38.2 24 30.9 2.9 37.8 23.3 307 6 306 165 -8.1 0 -7.9 -8.3 03/08/2006 06:00:00 30.9 2.9 38.2 23.7 30.9 3.1 38.2 24 30.1 2.9 38.6 22.9 307 6 297 165 -8 0 -7.9 -8.1 03/08/2006 06:10:00 31.3 2.6 36.7 23.7 31.4 2.6 36.7 23.3 30.3 2.8 36.7 22.1 308 7 308 165 -8 0 -7.9 -8.1 03/08/2006 06:20:00 29.8 2.7 36.3 24 29.8 2.8 37.1 23.3 28.6 3.1 36.3 21.4 307 7 301 165 -7.9 0 -7.6 -8.1 03/08/2006 06:30:00 30.1 2.4 36.7 24 30.1 2.5 36.7 23.3 28.9 2.8 35.9 21 306 7 296 165 -7.7 0 -7.4 -7.9 03/08/2006 06:40:00 31.2 2.5 36.7 22.1 31.2 2.6 37.1 21.4 30.5 2.8 37.5 21.4 307 6 306 165 -7.5 0 -7.2 -7.6 03/08/2006 06:50:00 30.8 3.1 38.6 22.9 30.8 3.2 38.6 22.9 29.5 3.5 36.3 20.6 306 7 305 165 -7.4 0 -7.2 -7.6 03/08/2006 07:00:00 34.1 2.7 40.5 26.3 34.1 2.7 40.9 25.6 33.3 2.6 40.5 26.3 309 7 310 165 -7.2 0 -7 -7.4 03/08/2006 07:10:00 34.6 2.6 40.5 29.1 34.6 2.7 41.3 29.1 33.5 2.6 40.1 26.3 307 6 307 165 -6.9 0.1 -6.6 -7.2 03/08/2006 07:20:00 34.6 2.7 42.4 27.5 34.7 2.8 42.4 27.5 33.7 2.6 40.1 25.2 307 6 298 165 -6.8 0 -6.6 -6.8 03/08/2006 07:30:00 36 3.1 42.8 28.7 36.1 3.2 43.6 28.3 35.3 3.2 43.2 26.8 307 5 301 165 -6.5 0 -6.4 -6.8 03/08/2006 07:40:00 36.5 2.7 43.6 29.4 36.6 2.8 43.6 29.4 35.8 2.9 44.8 26.3 308 5 302 165 -6.4 0 -6.1 -6.6 03/08/2006 07:50:00 37.2 2.7 43.6 29.8 37.3 2.9 43.9 28.7 36.4 3.2 45.1 26.8 307 5 307 165 -6.4 0 -6.1 -6.6 03/08/2006 08:00:00 37.5 2.3 43.2 30.6 37.7 2.4 43.2 30.9 36.9 2.3 42.8 29.4 307 5 303 165 -6.1 0 -5.9 -6.4 03/08/2006 08:10:00 36.5 2.6 42.1 28.3 36.5 2.8 42.4 28.3 35.9 2.9 42.4 27.5 307 5 302 165 -6 0.1 -5.7 -6.4 03/08/2006 08:20:00 34.4 2.5 41.3 27.1 34.4 2.6 41.3 28.3 34 2.7 40.9 26.3 310 5 302 165 -5.9 0 -5.7 -6.1 03/08/2006 08:30:00 32.4 2.9 40.5 23.3 32.4 3.1 40.9 22.9 32.1 2.9 39 24 313 6 304 165 -5.9 0 -5.7 -6.1 03/08/2006 08:40:00 34.1 2.7 41.3 26 34 2.8 41.6 24.8 33.6 2.7 40.9 25.2 311 5 304 165 -5.6 0.1 -5.3 -5.9 03/08/2006 08:50:00 33.3 2.2 39 26 33.1 2.2 38.6 25.2 32.9 2.6 39.4 26 313 6 316 165 -5.5 0 -5.5 -5.7 03/08/2006 09:00:00 32.7 2.7 39 23.7 32.7 2.7 39.4 23.7 32 2.9 40.1 22.9 311 6 310 165 -5.6 0 -5.5 -5.7 03/08/2006 09:10:00 34.2 2.7 39.8 27.1 34.2 2.7 39.4 27.1 33.4 2.9 39.4 26.3 310 6 309 165 -5.6 0 -5.5 -5.7 03/08/2006 09:20:00 31.9 2.5 38.6 24.4 31.8 2.6 38.6 24.4 31 2.7 40.1 23.7 312 6 314 165 -5.5 0 -5.5 -5.7 03/08/2006 09:30:00 34.3 3.1 42.1 26.8 34.3 3.1 42.1 26.3 34.3 3.1 42.1 24.4 314 6 310 165 -5.4 0.1 -5 -5.7 03/08/2006 09:40:00 35.7 2.7 41.3 27.9 35.8 2.7 41.3 27.9 35.9 2.9 42.1 25.6 314 5 311 165 -5.3 0 -5 -5.7 03/08/2006 09:50:00 30.9 2.5 38.2 22.9 30.8 2.6 37.1 22.9 30.7 2.9 37.5 22.1 316 7 311 165 -5.6 0 -5.5 -5.7 03/08/2006 10:00:00 31 2.6 36.7 21.4 30.9 2.6 36.7 21.4 30.6 2.8 37.1 22.9 316 8 313 165 -5.6 0 -5.5 -5.7 03/08/2006 10:10:00 30.9 2.5 37.5 22.1 30.8 2.6 37.5 22.6 30.2 2.7 37.8 22.1 312 7 306 165 -5.5 0 -5.3 -5.7 03/08/2006 10:20:00 32.4 2.6 40.5 26 32.4 2.6 40.9 25.6 32.1 2.6 38.6 25.2 312 6 313 165 -5.3 0 -5 -5.5 03/08/2006 10:30:00 34.6 2.5 40.5 28.7 34.6 2.5 40.9 27.9 34 2.6 41.3 28.3 310 6 312 165 -5.2 0 -5 -5.5 03/08/2006 10:40:00 35.8 2.2 41.6 26.8 35.7 2.3 42.1 26.8 35.3 2.4 40.9 28.7 310 6 310 165 -5.3 0.1 -5 -5.5 03/08/2006 10:50:00 36.8 2.8 43.6 29.1 36.9 2.9 43.9 28.7 36.6 2.9 43.6 27.5 310 6 307 165 -5.3 0 -5 -5.3 03/08/2006 11:00:00 35.4 2.6 41.6 27.5 35.4 2.7 42.1 27.5 34.9 2.8 41.6 26 310 6 308 165 -5.1 0.1 -4.6 -5.3 03/08/2006 11:10:00 35.2 2.9 42.8 27.5 35.3 3.1 43.2 27.5 34.7 2.9 43.9 27.1 311 6 309 165 -4.6 0 -4.4 -4.8 03/08/2006 11:20:00 35.3 2.7 42.4 26.3 35.3 2.8 42.4 26 34.9 2.7 41.3 26.8 310 6 300 165 -4.6 0 -4.4 -4.6 03/08/2006 11:30:00 34.6 2.3 40.9 28.7 34.7 2.3 41.3 28.7 34.6 2.4 40.5 28.3 312 6 309 165 -4.5 0 -4.4 -4.6 03/08/2006 11:40:00 35.3 2.8 40.9 25.6 35.3 2.9 41.6 24.8 34.8 3.2 41.3 24 310 6 307 165 -4.7 0 -4.4 -4.8 03/08/2006 11:50:00 36.1 2.1 42.4 30.2 36.2 2.2 42.1 30.2 35.3 2.5 40.5 28.7 306 4 300 165 -4.4 0 -4.4 -4.6 03/08/2006 12:00:00 30.9 2.4 36.3 23.3 30.8 2.4 36.3 23.3 30.5 2.8 37.1 22.9 314 7 307 165 -4.4 0 -4.2 -4.6 03/08/2006 12:10:00 31.5 2.5 39 26 31.5 2.5 38.6 26 31.3 2.7 39.8 24.4 314 6 310 165 -4.5 0 -4.4 -4.6 03/08/2006 12:20:00 29.8 2.8 35.5 21.4 29.8 2.8 35.9 20.6 28.9 2.9 35.2 21.8 310 8 310 165 -4.3 0 -4.2 -4.6 03/08/2006 12:30:00 31.6 3.1 38.2 22.1 31.6 3.1 38.6 21.8 30.5 3.2 37.8 22.1 307 6 302 165 -4.2 0 -3.9 -4.4 03/08/2006 12:40:00 29.9 2.6 34.8 21.4 29.8 2.6 34.8 21.8 28.7 2.7 34 20.2 309 6 304 165 -4 0 -3.7 -4.2 03/08/2006 12:50:00 27.7 1.9 33.2 22.9 27.6 1.9 33.2 22.6 26.9 2.4 33.6 20.6 312 5 308 165 -3.9 0 -3.7 -4.2 03/08/2006 13:00:00 27.4 2.4 33.6 20.6 27.3 2.4 33.6 21 26.6 2.7 34 20.2 312 6 315 165 -3.6 0.1 -3.5 -3.9 03/08/2006 13:10:00 25.6 2.7 32.9 18.7 25.6 2.7 32.4 19.1 25.1 3.1 35.5 18.3 314 7 320 165 -3.4 0 -3.3 -3.5 03/08/2006 13:20:00 27.8 2.5 33.6 21.4 27.8 2.5 33.6 21.8 27.1 2.7 33.2 19.5 312 7 314 165 -3.5 0 -3.3 -3.5 03/08/2006 13:30:00 26.5 2.5 36.3 19.9 26.4 2.5 36.7 19.5 25.3 2.7 35.5 17.2 311 7 303 165 -3.4 0 -3.3 -3.5 03/08/2006 13:40:00 28.9 2.6 34.4 22.6 28.9 2.7 34.8 22.6 27.8 3.1 36.7 19.5 309 6 312 165 -3.3 0 -3 -3.5 03/08/2006 13:50:00 26.3 2.8 33.6 19.9 26.2 2.8 33.2 19.9 25.7 3.3 34 18.7 313 7 319 165 -3.1 0.1 -2.8 -3.3 03/08/2006 14:00:00 26.4 2.3 32.1 20.6 26.3 2.3 31.8 20.6 25 2.9 32.1 17.2 311 8 312 165 -3.1 0 -3 -3.3 03/08/2006 14:10:00 27 2.3 31.3 21.4 27 2.3 31.8 21.8 24.9 2.7 32.4 18.3 307 6 303 165 -3.2 0 -2.8 -3.3 03/08/2006 14:20:00 26.9 2.5 32.1 20.2 26.8 2.5 32.1 19.9 25 2.8 30.9 17.2 307 6 301 165 -3 0 -2.8 -3.3 03/08/2006 14:30:00 25.5 2.2 31.3 19.5 25.5 2.2 30.9 19.5 24.4 2.7 30.6 16.8 310 6 308 165 -2.8 0.1 -2.6 -3 03/08/2006 14:40:00 23.9 3.1 31.3 15.3 23.8 3.1 31.3 14.5 23 2.8 30.2 14.1 313 7 305 165 -2.5 0 -2.1 -2.8 03/08/2006 14:50:00 20.9 2.6 27.9 13.7 20.8 2.6 27.9 13.7 19.1 2.6 28.3 13 310 8 311 165 -2.2 0 -2.1 -2.6 03/08/2006 15:00:00 22.9 3.3 31.3 15.6 22.8 3.3 31.8 16.1 21.8 3.2 29.8 15.6 315 8 302 165 -2 0 -1.9 -2.1 03/08/2006 15:10:00 23.8 3.2 37.5 17.6 23.7 3.2 37.8 17.6 22.8 3.2 36.3 14.9 315 8 305 165 -2.1 0 -1.9 -2.1 03/08/2006 15:20:00 27 3.2 34.4 16.4 26.9 3.2 34.4 17.2 26.7 3.3 34.4 14.9 320 10 315 165 -2 0 -1.9 -2.1 03/08/2006 15:30:00 23.2 3.3 30.9 13.7 23.1 3.3 30.9 13.7 22.5 3.5 30.9 14.1 322 9 315 165 -2 0 -1.9 -2.1 03/08/2006 15:40:00 22.3 2.8 28.7 14.1 22.2 2.8 28.3 14.9 21.1 2.9 27.9 12.6 315 10 300 165 -2.3 0.2 -1.9 -2.6 03/08/2006 15:50:00 24.7 2.9 33.6 13 24.6 2.9 34 13.7 23.6 3.3 32.9 13 314 9 312 165 -2.7 0 -2.6 -2.8 03/08/2006 16:00:00 25 3.3 32.9 18.3 24.8 3.3 32.9 18.3 24.7 3.5 33.6 17.9 317 6 319 165 -2.8 0 -2.6 -3 03/08/2006 16:10:00 24.5 2.5 31.8 17.9 24.4 2.5 31.3 17.9 23.7 2.6 30.6 17.2 315 8 307 165 -2.9 0 -2.8 -3 03/08/2006 16:20:00 25.3 2.5 31.8 17.6 25.2 2.6 32.1 17.6 23.4 2.7 31.3 15.3 308 7 304 165 -3.3 0.1 -3 -3.5 03/08/2006 16:30:00 25.4 2.3 30.9 20.6 25.3 2.3 30.9 20.6 23.8 2.4 29.1 16.4 309 8 300 165 -3.5 0 -3.3 -3.7 03/08/2006 16:40:00 28.4 2.7 33.6 20.6 28.3 2.7 33.6 21 27 3.2 33.6 18.3 309 7 312 165 -3.5 0 -3.3 -3.5 03/08/2006 16:50:00 29.3 2.6 36.7 22.6 29.3 2.6 36.7 22.6 28.5 2.6 34.8 20.2 311 8 307 165 -3.6 0 -3.5 -3.5 03/08/2006 17:00:00 30.6 2.4 37.1 23.3 30.5 2.4 36.7 23.3 29.9 2.4 35.9 23.3 311 7 302 165 -3.6 0 -3.5 -3.7 03/08/2006 17:10:00 30.3 2.1 35.9 24.4 30.3 2.2 35.9 24.4 30 2.2 36.3 25.2 311 6 307 165 -3.6 0 -3.5 -3.7 03/08/2006 17:20:00 34 2.2 39.4 27.5 34 2.3 39 27.5 34.1 2.4 40.1 26.8 318 4 323 165 -3.8 0.2 -3.5 -4.2 03/08/2006 17:30:00 34.9 2.3 39.8 28.3 34.9 2.3 39.8 28.3 34.9 2.6 40.1 27.9 318 5 319 165 -4.4 0 -4.2 -4.6 03/08/2006 17:40:00 34.2 2.2 39.4 27.5 34.1 2.2 39.8 27.1 34 2.4 40.5 26.3 320 6 316 165 -4.5 0 -4.4 -4.6 03/08/2006 17:50:00 32.7 2.5 38.6 25.6 32.7 2.6 39.8 25.6 32.9 2.5 39.4 24.4 316 7 310 165 -4.6 0 -4.4 -4.6 03/08/2006 18:00:00 36.7 2.3 42.1 29.8 36.9 2.4 42.8 29.8 37 2.6 42.8 30.2 312 5 315 165 -4.7 0 -4.6 -4.8 03/08/2006 18:10:00 35.4 1.9 39.4 28.7 35.5 2 40.1 28.7 35.2 2.4 41.3 29.1 312 7 304 165 -4.7 0 -4.6 -4.8 03/08/2006 18:20:00 34.7 2.5 39.8 28.3 34.9 2.5 39.8 28.3 34.2 2.6 41.3 26.8 310 6 298 165 -4.7 0 -4.6 -4.6 03/08/2006 18:30:00 34.3 2.4 40.1 26.8 34.4 2.4 40.1 26.8 34 2.5 40.9 26.3 312 6 304 165 -4.7 0 -4.4 -4.8 03/08/2006 18:40:00 31.7 3.3 39 25.2 31.8 3.5 39 24.4 31.9 3.8 39.4 23.3 313 5 316 165 -4.7 0 -4.6 -5 03/08/2006 18:50:00 29.3 2.2 35.2 24.4 29.3 2.2 35.5 24.4 28.2 2.4 33.6 21.8 305 8 304 165 -4.7 0 -4.6 -4.8 03/08/2006 19:00:00 26.7 2.2 32.4 21.8 26.6 2.3 32.4 21.8 25.3 2.6 33.6 19.1 308 7 305 165 -4.7 0 -4.4 -4.6 03/08/2006 19:10:00 26.3 2.1 31.8 20.6 26.3 2.2 31.3 20.2 25 2.8 31.3 17.2 309 7 297 165 -4.7 0 -4.6 -4.8 03/08/2006 19:20:00 24.2 2.3 30.2 17.2 24.2 2.3 30.6 17.2 23.7 2.6 28.7 14.9 313 8 300 165 -4.8 0 -4.6 -5 03/08/2006 19:30:00 24 2.3 30.2 17.6 24 2.3 29.8 17.6 21.9 3.1 29.8 15.3 307 7 304 165 -4.9 0 -4.6 -5 03/08/2006 19:40:00 24.2 2.5 32.4 14.9 24.2 2.5 32.4 15.3 21.6 3.3 29.4 13.7 303 9 302 165 -5 0 -4.8 -5.3 03/08/2006 19:50:00 22.9 2.3 27.9 17.2 22.9 2.3 28.3 17.2 20.7 2.7 27.5 14.1 304 9 309 165 -5 0 -4.8 -5.3 03/08/2006 20:00:00 23.2 2.4 29.4 17.2 23.2 2.4 29.4 16.8 20 2.8 28.7 14.5 301 8 290 165 -5.2 0.1 -5 -5.3 03/08/2006 20:10:00 24.7 2.5 30.9 18.7 24.7 2.5 31.3 18.7 22.8 3.1 31.3 16.1 305 7 308 165 -5.2 0 -5 -5.5 03/08/2006 20:20:00 24.1 2.6 30.6 17.6 24.1 2.7 30.6 16.8 22.7 3.1 31.8 15.3 308 9 312 165 -5.2 0 -5 -5.3 03/08/2006 20:30:00 25.5 2.5 31.8 18.3 25.4 2.6 31.8 18.7 24.7 2.8 31.3 16.4 313 8 304 165 -5.1 0 -5 -5.3 03/08/2006 20:40:00 25.3 2.4 30.9 19.9 25.3 2.5 30.9 18.7 24.8 2.4 30.6 17.9 313 7 308 165 -5.1 0 -5 -5.3 03/08/2006 20:50:00 25.9 2.7 32.9 20.6 25.9 2.8 32.9 18.7 24.8 2.9 31.8 18.3 310 8 300 165 -5.3 0 -5 -5.5 03/08/2006 21:00:00 27.5 2.5 32.9 19.1 27.5 2.5 33.2 19.5 26.6 2.7 34 19.9 310 7 312 165 -5.3 0 -5 -5.5 03/08/2006 21:10:00 26.8 2.4 34.8 20.6 26.7 2.5 34 19.9 26.6 2.7 34 19.5 314 6 321 165 -5.4 0 -5.3 -5.5 03/08/2006 21:20:00 26.2 2.3 32.1 20.6 26.2 2.3 31.3 21 26.1 2.6 32.1 19.1 313 6 307 165 -5.5 0 -5.3 -5.7 03/08/2006 21:30:00 26 2.4 33.2 20.2 25.9 2.5 32.9 20.2 25 2.7 32.9 17.6 313 9 315 165 -5.5 0 -5.5 -5.7 03/08/2006 21:40:00 24.5 2.7 31.3 18.3 24.4 2.7 31.3 17.9 23.6 2.9 31.8 17.2 313 8 303 165 -5.6 0.1 -5.5 -5.9 03/08/2006 21:50:00 24.5 2.3 29.4 17.9 24.4 2.3 29.1 17.2 23.9 2.8 30.9 16.4 315 7 332 165 -5.8 0 -5.7 -6.1 03/08/2006 22:00:00 26.7 2.5 33.6 20.2 26.6 2.5 33.2 20.6 26 2.7 33.2 18.7 315 6 314 165 -5.9 0 -5.7 -5.9 03/08/2006 22:10:00 30.4 2.8 36.3 22.1 30.4 2.8 36.7 22.1 30 2.9 36.3 21.8 312 6 313 165 -6 0 -5.7 -6.1 03/08/2006 22:20:00 31.5 2.8 37.5 21.8 31.5 2.8 39 21.4 31.2 2.9 37.8 22.1 314 6 312 165 -6.2 0.1 -6.1 -6.4 03/08/2006 22:30:00 31.8 3.1 40.5 24.4 31.8 3.1 40.1 24.4 31.2 3.2 40.5 23.7 312 7 318 165 -6.3 0 -5.9 -6.6 03/08/2006 22:40:00 31.9 2.7 37.8 23.3 31.8 2.8 38.2 23.3 31.6 2.5 37.1 23.3 314 7 311 165 -6.2 0 -6.1 -6.6 03/08/2006 22:50:00 33.8 3.1 40.9 25.6 33.8 3.1 40.9 26 33.4 3.3 40.5 24 312 6 310 165 -6.1 0.1 -5.7 -6.4 03/08/2006 23:00:00 36.5 2.8 42.4 27.9 36.4 2.8 42.4 28.7 36 2.9 42.8 27.9 313 5 312 165 -6 0 -5.7 -6.1 03/08/2006 23:10:00 36.9 2.2 42.1 30.2 36.8 2.3 42.4 29.8 36.7 2.5 42.4 27.9 316 6 314 165 -6 0 -5.7 -6.1 03/08/2006 23:20:00 38.2 2.5 43.6 32.1 38.2 2.7 44.8 31.8 38.2 2.9 44.8 29.8 318 6 310 165 -6 0 -5.7 -6.1 03/08/2006 23:30:00 38.2 2.1 42.8 32.4 38.5 2.3 43.6 32.4 38.6 2.1 43.2 33.2 312 4 313 165 -5.9 0 -5.7 -6.1 03/08/2006 23:40:00 37.1 2.3 45.1 30.6 37.2 2.4 45.1 30.2 37.2 2.5 44.8 30.2 313 5 306 165 -5.8 0 -5.5 -5.9 03/08/2006 23:50:00 36.2 2.5 42.1 27.5 36.3 2.6 42.4 26.8 36.5 2.7 43.9 26.3 315 5 310 165 -5.7 0 -5.5 -5.7 03/09/2006 00:00:00 35.9 2.2 40.5 28.7 36 2.3 40.5 29.1 36 2.5 40.9 28.7 314 5 317 165 -5.6 0 -5.5 -5.7 03/09/2006 00:10:00 35.8 2.1 40.5 28.7 35.8 2.2 40.5 28.7 35.8 2.4 40.9 28.3 314 5 307 165 -5.5 0 -5.5 -5.7 03/09/2006 00:20:00 35.8 2.2 40.5 28.7 36 2.3 40.9 29.4 36.1 2.5 40.9 27.1 313 5 303 165 -5.6 0 -5.5 -5.7 03/09/2006 00:30:00 33.1 2.4 37.8 27.1 33.2 2.4 38.2 27.1 33.2 2.7 39.8 27.1 314 4 319 165 -5.6 0 -5.3 -5.7 03/09/2006 00:40:00 32.2 2.2 37.8 26 32.3 2.4 37.8 26 32.1 2.5 40.1 26 312 5 305 165 -5.5 0 -5.3 -5.7 03/09/2006 00:50:00 32.2 2.2 37.5 26.3 32.2 2.2 38.2 26 31.8 2.2 38.2 24.8 312 5 314 165 -5.4 0 -5.3 -5.7 03/09/2006 01:00:00 31.9 2.2 37.5 26 31.9 2.3 37.8 26 31.8 2.5 38.2 24 312 6 308 165 -5.4 0.1 -5.3 -5.7 03/09/2006 01:10:00 32.8 2 37.5 26 32.9 2.1 37.5 26 32.8 2.2 37.5 25.6 314 5 310 165 -5.2 0 -5 -5.5 03/09/2006 01:20:00 31.4 2.1 37.8 26.3 31.5 2.2 37.5 26.3 31.2 2.3 37.1 24.8 311 4 307 165 -5.1 0 -4.8 -5.3 03/09/2006 01:30:00 33.1 2 37.5 26 33.2 2.1 37.8 25.6 33.1 2.3 39.4 26 313 5 313 165 -5 0 -4.8 -5.3 03/09/2006 01:40:00 32.2 2 35.9 26 32.3 2.1 36.7 26 32.4 2.1 38.2 24.4 312 5 316 165 -5.3 0 -5 -5.5 03/09/2006 01:50:00 32.1 2.4 37.1 25.6 32.1 2.4 36.7 26 31.5 2.5 36.7 24.8 309 5 311 165 -5.2 0 -5 -5.5 03/09/2006 02:00:00 31.2 2.3 37.1 25.2 31.2 2.3 37.5 24.8 30.9 2.5 37.1 22.9 310 5 308 165 -5.1 0 -5 -5.3 03/09/2006 02:10:00 30.5 2.8 37.8 24 30.6 2.8 37.8 24 30 3.3 39 19.1 310 6 313 165 -5.2 0 -5 -5.3 03/09/2006 02:20:00 30.8 2.5 37.8 24.4 30.8 2.6 38.2 23.3 30.2 2.7 38.2 24.8 311 6 312 165 -5.2 0 -5 -5.5 03/09/2006 02:30:00 31.5 2.5 36.3 25.6 31.5 2.6 36.7 24.4 31.4 2.9 37.8 24.4 314 6 314 165 -5.3 0 -5 -5.3 03/09/2006 02:40:00 32.7 2.6 38.2 26 32.8 2.7 38.6 25.6 32.4 2.7 38.6 25.6 310 5 310 165 -5.3 0 -5 -5.5 03/09/2006 02:50:00 32.9 2.9 39 23.3 32.9 2.9 39 24 32.5 3.1 38.2 22.9 313 6 305 165 -5.7 0.1 -5.5 -6.1 03/09/2006 03:00:00 34.3 2.5 40.1 28.7 34.4 2.5 40.1 28.3 33.7 2.6 40.5 26.3 311 7 307 165 -6 0 -5.7 -6.1 03/09/2006 03:10:00 32.7 2.5 38.6 26 32.8 2.6 39 26 32.4 2.7 40.5 24 311 6 305 165 -6 0 -5.9 -6.1 03/09/2006 03:20:00 35.4 2.1 41.3 30.6 35.5 2.2 40.9 30.9 35.5 2.3 41.6 29.8 314 4 311 165 -5.9 0 -5.7 -6.1 03/09/2006 03:30:00 32.7 1.9 37.1 26.3 32.7 2 37.1 26.8 32.4 2 36.3 27.1 314 6 315 165 -6 0 -5.7 -6.1 03/09/2006 03:40:00 34.2 2.3 40.1 27.1 34.2 2.4 39.4 26.8 34.1 2.5 42.1 25.2 316 6 321 165 -5.9 0 -5.7 -6.1 03/09/2006 03:50:00 33.5 3.2 40.9 24.4 33.5 3.3 41.3 24.4 33.4 3.6 40.9 23.7 315 6 314 165 -5.9 0 -5.7 -5.9 03/09/2006 04:00:00 33.2 2.4 39 27.1 33.3 2.4 39.4 27.1 32.7 2.5 38.6 26.3 312 6 310 165 -6.1 0 -5.9 -6.4 03/09/2006 04:10:00 33.6 2.8 40.5 26 33.6 2.9 40.9 26 33.6 2.8 40.9 26.8 314 6 306 165 -6.2 0 -6.1 -6.4 03/09/2006 04:20:00 32.7 2.7 38.2 26 32.8 2.7 38.6 26 32.5 2.7 38.6 22.6 313 6 305 165 -6.1 0 -5.9 -6.4 03/09/2006 04:30:00 32.4 2.2 37.1 26 32.5 2.4 37.5 25.6 32.2 2.5 39.4 25.2 312 6 313 165 -6 0 -5.7 -6.1 03/09/2006 04:40:00 32.2 2.1 36.7 25.2 32.2 2.2 36.3 25.2 31.8 2.5 36.7 23.7 314 6 307 165 -6 0 -5.7 -6.1 03/09/2006 04:50:00 31.1 2.6 40.5 24 31 2.6 40.5 24 30.9 2.5 39.4 24 317 8 302 165 -5.8 0 -5.5 -5.9 03/09/2006 05:00:00 33.2 2.8 40.5 24.8 33.2 2.9 41.3 23.7 33.3 3.1 41.6 23.3 318 6 316 165 -5.6 0 -5.5 -5.7 03/09/2006 05:10:00 31.2 1.9 35.5 24.8 31.2 1.9 35.5 24.4 30.9 2.3 36.3 24 313 6 322 165 -5.8 0 -5.7 -5.9 03/09/2006 05:20:00 31 1.7 35.9 27.1 31 1.8 35.9 26.8 30.8 2.1 37.5 24.4 312 6 316 165 -5.9 0 -5.7 -6.1 03/09/2006 05:30:00 31.9 2.2 38.6 26.3 31.8 2.3 37.8 26.3 32.1 2.4 38.6 26.3 317 7 319 165 -6 0 -5.7 -6.1 03/09/2006 05:40:00 34.6 2.8 42.4 28.7 34.6 3.1 43.2 27.9 34.3 3.1 46.2 26.8 315 6 306 165 -6 0 -5.7 -6.1 03/09/2006 05:50:00 35.7 2.7 42.4 27.9 35.8 2.8 42.4 27.9 35.3 2.7 41.3 27.5 312 6 307 165 -6 0 -5.7 -6.1 03/09/2006 06:00:00 33.3 2.7 39.8 24.4 33.3 2.8 39.8 24 33.2 2.9 40.1 26 316 7 313 165 -6.1 0 -5.9 -6.4 03/09/2006 06:10:00 35.7 2.7 41.6 29.8 35.7 2.8 42.1 29.4 35.4 2.9 42.8 27.9 315 6 320 165 -6 0 -5.9 -6.1 03/09/2006 06:20:00 37.8 2.5 42.8 30.9 37.9 2.7 43.6 30.2 37.6 2.9 44.8 29.1 313 5 316 165 -6 0 -5.7 -6.1 03/09/2006 06:30:00 37.2 2.5 43.2 30.2 37.2 2.6 43.2 30.2 37.1 2.7 44.3 28.7 315 6 313 165 -6 0 -5.7 -6.1 03/09/2006 06:40:00 36.6 2.5 43.2 30.6 36.6 2.6 43.6 30.2 36.8 2.6 43.2 29.8 316 6 312 165 -6.1 0 -5.9 -6.1 03/09/2006 06:50:00 37.2 2.2 42.4 31.8 37.3 2.3 42.8 30.9 37.1 2.4 43.6 30.2 313 5 307 165 -6 0 -5.7 -6.1 03/09/2006 07:00:00 37.4 2.3 42.1 30.2 37.5 2.4 42.1 29.8 37.5 2.5 42.8 29.1 314 5 321 165 -6 0 -5.7 -6.1 03/09/2006 07:10:00 37.6 2.4 42.8 28.3 37.7 2.5 42.8 28.3 37.5 2.7 42.8 27.9 312 5 305 165 -5.9 0 -5.7 -6.1 03/09/2006 07:20:00 39.3 2.3 44.8 32.9 39.6 2.6 45.1 32.4 39.2 2.7 45.5 29.1 310 5 308 165 -5.8 0 -5.5 -5.9 03/09/2006 07:30:00 39.3 2.5 47.7 30.6 39.7 2.7 47 31.8 39.4 2.8 45.9 30.6 311 5 305 165 -5.8 0 -5.7 -5.9 03/09/2006 07:40:00 38.8 2.4 44.8 31.8 39.1 2.6 45.1 32.1 38.8 2.6 44.8 30.9 312 5 303 165 -5.8 0 -5.5 -5.9 03/09/2006 07:50:00 39.1 2.7 44.8 30.9 39.4 2.9 45.9 30.2 39.1 2.9 45.9 30.9 313 6 309 165 -5.6 0 -5.5 -5.7 03/09/2006 08:00:00 40.3 2.4 46.2 33.2 40.7 2.6 46.2 34 40.4 2.8 46.6 32.4 313 5 314 165 -5.5 0 -5.3 -5.7 03/09/2006 08:10:00 39.2 2.2 45.1 33.6 39.5 2.4 45.1 34 39.4 2.6 45.1 32.1 313 5 310 165 -5.4 0 -5.3 -5.7 03/09/2006 08:20:00 38.7 2.4 43.6 32.4 38.8 2.6 43.9 31.8 38.8 2.6 44.8 30.9 314 6 318 165 -5.3 0 -5.3 -5.5 03/09/2006 08:30:00 39.1 2.1 44.8 32.4 39.3 2.2 44.8 32.1 39 2.5 44.8 29.1 313 6 307 165 -5.3 0 -5 -5.5 03/09/2006 08:40:00 38.8 2.3 44.3 32.9 39 2.5 45.1 32.4 39 2.6 45.9 29.4 316 6 310 165 -5.1 0 -5 -5.3 03/09/2006 08:50:00 38.9 2.3 43.6 32.1 39 2.5 43.9 32.4 38.8 2.7 45.1 30.9 316 6 308 165 -5 0 -4.8 -5.3 03/09/2006 09:00:00 37.4 2.1 42.8 30.9 37.4 2.3 43.6 30.9 37.6 2.4 43.9 30.6 318 6 312 165 -4.9 0 -4.8 -5 03/09/2006 09:10:00 36.8 1.9 40.9 31.8 36.7 2 40.9 31.3 36.8 2.2 42.8 30.9 316 6 305 165 -4.8 0 -4.6 -5 03/09/2006 09:20:00 36.4 2.1 42.1 28.3 36.4 2.1 42.1 28.3 36.6 2.2 42.4 29.4 315 5 309 165 -4.7 0 -4.4 -4.8 03/09/2006 09:30:00 37.6 2.7 43.6 30.6 37.8 2.9 43.9 30.2 37.9 2.9 43.9 30.2 315 5 314 165 -4.7 0 -4.4 -4.6 03/09/2006 09:40:00 36.8 2.4 43.2 29.1 36.8 2.5 43.2 30.6 36.8 2.6 44.3 27.9 318 6 315 165 -4.5 0 -4.4 -4.6 03/09/2006 09:50:00 35.8 2.1 40.5 30.2 35.8 2.2 41.3 29.8 36 2.4 42.1 29.1 318 6 316 165 -4.5 0 -4.4 -4.6 03/09/2006 10:00:00 34.5 2.2 40.9 28.7 34.4 2.2 40.1 28.3 34.4 2.4 39.4 27.1 316 7 304 165 -4.4 0 -4.4 -4.6 03/09/2006 10:10:00 35.1 2.2 40.9 29.1 35 2.3 40.9 28.3 35.3 2.5 41.3 27.5 318 5 323 165 -4.4 0 -4.4 -4.6 03/09/2006 10:20:00 33.3 2.5 38.6 24 33.2 2.5 38.2 23.7 33.2 2.6 39.4 24 317 7 316 165 -4.4 0 -4.2 -4.6 03/09/2006 10:30:00 33.9 2.2 39 27.1 33.8 2.3 38.6 27.5 33.7 2.5 39.8 26 317 6 303 165 -4.4 0 -4.4 -4.6 03/09/2006 10:40:00 34.8 2.2 42.1 29.1 34.8 2.3 42.8 29.4 34.8 2.7 43.9 28.3 315 5 316 165 -4.4 0 -4.4 -4.6 03/09/2006 10:50:00 36 2.6 41.3 29.4 36.2 2.7 41.3 29.1 35.9 2.7 43.2 29.8 311 5 309 165 -4.3 0 -4.2 -4.6 03/09/2006 11:00:00 37.1 2.5 42.8 30.2 37.3 2.6 42.8 29.8 37.2 2.8 43.2 29.4 313 6 313 165 -4.2 0.1 -3.9 -4.4 03/09/2006 11:10:00 38.3 1.7 42.8 32.4 38.7 2 43.2 32.4 38.7 2.2 43.2 31.8 314 5 313 165 -3.8 0.1 -3.5 -3.9 03/09/2006 11:20:00 36.2 2.6 41.6 29.4 36.3 2.7 42.1 29.1 36.7 2.8 42.4 28.3 316 5 312 165 -3.7 0 -3.5 -3.9 03/09/2006 11:30:00 36.3 2.3 43.6 30.2 36.3 2.4 44.3 30.2 36.5 2.6 43.9 28.7 315 5 309 165 -3.8 0 -3.5 -3.9 03/09/2006 11:40:00 35.4 2.1 40.5 29.1 35.5 2.2 40.9 29.1 35.4 2.4 40.9 25.6 314 5 310 165 -3.8 0 -3.5 -3.9 03/09/2006 11:50:00 33.8 2.3 38.6 26 33.8 2.3 39 26.3 33.7 2.6 39.8 25.2 313 5 319 165 -3.9 0 -3.7 -4.2 03/09/2006 12:00:00 32.4 1.8 37.5 27.1 32.5 1.9 37.8 26.8 32.5 2 38.2 26.3 313 5 322 165 -3.8 0 -3.5 -4.2 03/09/2006 12:10:00 31.6 2.4 37.1 23.3 31.6 2.5 37.8 24 31.4 2.6 38.6 25.2 314 5 312 165 -3.7 0 -3.5 -3.9 03/09/2006 12:20:00 31.6 2.1 35.9 25.2 31.6 2.2 36.7 24 31.4 2.2 36.7 25.2 313 6 310 165 -3.7 0 -3.5 -3.9 03/09/2006 12:30:00 29.3 1.9 34 24 29.2 1.9 33.6 24.4 29.3 2.2 34.8 23.7 317 6 318 165 -3.5 0 -3.3 -3.7 03/09/2006 12:40:00 28.7 1.5 33.2 23.7 28.6 1.5 32.4 22.9 28.1 2 33.6 21.8 313 6 305 165 -3.5 0 -3.3 -3.5 03/09/2006 12:50:00 29.5 1.9 34.4 23.7 29.5 1.9 33.6 23.7 28.9 1.9 33.6 24.4 312 6 305 165 -3.4 0 -3.3 -3.5 03/09/2006 13:00:00 29.8 2.1 35.5 24.8 29.7 2.1 35.5 24 29.3 2.3 34.8 21.8 315 7 314 165 -3.3 0 -3.3 -3.5 03/09/2006 13:10:00 33 1.7 37.1 27.1 33 1.8 37.1 27.1 32.7 2.1 37.5 27.1 312 5 308 165 -3.3 0 -3.3 -3.5 03/09/2006 13:20:00 34.3 2.3 39.4 28.7 34.4 2.4 39 27.9 34.2 2.7 40.9 27.1 314 6 310 165 -3.2 0 -3 -3.5 03/09/2006 13:30:00 34 2 38.6 28.3 34.1 2.1 39.4 27.9 34.2 2.3 39 27.1 314 6 308 165 -3.1 0 -3 -3.3 03/09/2006 13:40:00 34.8 1.9 39.4 28.3 34.9 1.9 39.8 28.3 35 2.3 40.9 27.1 314 6 310 165 -3 0 -2.8 -3.3 03/09/2006 13:50:00 35.7 2.3 41.3 27.9 35.8 2.3 41.3 28.3 36.1 2.5 42.1 27.9 315 6 310 165 -3 0 -2.8 -3.3 03/09/2006 14:00:00 36.2 1.7 39.4 30.6 36.4 1.7 40.1 30.6 36.3 2 40.1 30.6 312 5 311 165 -3 0 -2.8 -3.3 03/09/2006 14:10:00 35.3 1.7 39.8 30.6 35.4 1.7 39.8 30.6 35.2 2.1 39.8 29.8 311 4 307 165 -3 0 -2.8 -3 03/09/2006 14:20:00 34.1 2.1 39.4 26.8 34.2 2.2 39 26.8 33.9 2.2 37.8 27.9 312 5 301 165 -3 0 -2.8 -3 03/09/2006 14:30:00 32.9 1.9 36.7 27.1 33 2 37.1 26.8 32.9 2.2 37.8 24 313 5 312 165 -3 0 -2.8 -3 03/09/2006 14:40:00 33.3 2.2 39.8 26 33.3 2.3 39.8 24.8 33.3 2.4 40.5 27.5 316 5 311 165 -3 0 -2.8 -3.3 03/09/2006 14:50:00 34 2.3 39.8 28.3 34 2.4 39.8 27.9 34.2 2.5 39.8 26.8 315 6 312 165 -3 0 -2.8 -3 03/09/2006 15:00:00 34.2 2 40.9 29.4 34.2 2.1 40.5 29.1 34.3 2.4 41.6 27.1 315 5 315 165 -2.8 0 -2.6 -2.8 03/09/2006 15:10:00 35 2.3 42.8 28.7 35 2.4 42.4 28.7 35.3 2.6 42.8 27.5 315 5 312 165 -2.8 0 -2.6 -2.8 03/09/2006 15:20:00 33.3 1.9 39.8 28.7 33.3 2.1 39.8 28.3 33.5 2.4 40.9 27.1 316 5 311 165 -2.8 0 -2.6 -2.8 03/09/2006 15:30:00 34.3 1.7 38.2 28.3 34.4 1.7 38.2 27.9 34.6 2 39.4 28.3 314 4 307 165 -2.7 0.1 -2.6 -2.8 03/09/2006 15:40:00 33.4 1.7 38.2 28.3 33.5 1.8 37.8 28.7 33.7 1.9 37.8 27.5 315 3 320 165 -2.6 0 -2.6 -2.8 03/09/2006 15:50:00 33.7 1.8 39.4 27.9 33.8 1.9 39 27.9 34.1 2.2 40.1 28.3 315 5 307 165 -2.5 0 -2.4 -2.8 03/09/2006 16:00:00 34.1 2.1 39 27.9 34.1 2.2 39 27.5 34.5 2.4 40.1 27.1 317 4 312 165 -2.5 0 -2.4 -2.6 03/09/2006 16:10:00 33.9 1.6 37.1 27.5 33.9 1.7 37.5 27.5 34.1 1.9 38.2 25.6 316 4 318 165 -2.4 0 -2.1 -2.6 03/09/2006 16:20:00 33.8 1.7 38.2 27.9 34 1.8 38.2 28.3 34.2 2.1 40.5 26.8 313 3 315 165 -2.3 0 -2.1 -2.6 03/09/2006 16:30:00 31.8 1.8 35.9 26.8 31.8 1.9 35.5 26.3 31.4 2.1 35.9 25.6 311 5 307 165 -2.3 0 -2.1 -2.6 03/09/2006 16:40:00 32.4 1.7 35.9 28.3 32.4 1.8 35.9 27.5 31.6 2.2 35.9 24.8 309 5 307 165 -2.4 0 -2.1 -2.6 03/09/2006 16:50:00 33 2.1 39.8 26.3 33 2.2 39.4 26.3 32.2 2.3 38.6 26.3 308 4 306 165 -2.2 0 -2.1 -2.6 03/09/2006 17:00:00 32.9 2 37.5 26 32.9 2 37.1 26 32.3 2.3 37.1 23.7 308 4 304 165 -2.2 0 -1.9 -2.4 03/09/2006 17:10:00 32.6 2 37.5 27.1 32.7 2.1 37.1 27.1 32.1 2.2 36.7 26.3 309 5 307 165 -2.4 0 -2.1 -2.6 03/09/2006 17:20:00 32.2 1.8 36.3 26 32.3 1.9 36.3 26 32 2.2 37.1 22.1 311 5 310 165 -2.5 0 -2.4 -2.6 03/09/2006 17:30:00 31.6 1.7 35.5 25.6 31.7 1.8 35.5 24.4 31.4 2 35.9 24.8 311 5 307 165 -2.5 0 -2.6 -2.6 03/09/2006 17:40:00 30.7 1.9 34.8 23.7 30.7 1.9 34.8 24 30.3 2.3 34.8 23.3 310 4 305 165 -2.5 0 -2.4 -2.6 03/09/2006 17:50:00 30.3 1.7 34 22.9 30.3 1.7 34.4 22.9 29.8 1.9 34.4 23.3 310 4 313 165 -2.5 0 -2.6 -2.6 03/09/2006 18:00:00 30.7 1.8 35.2 23.7 30.8 1.9 35.2 24.4 30.3 1.9 34.4 23.7 310 5 307 165 -2.5 0 -2.6 -2.8 03/09/2006 18:10:00 31.9 1.8 37.8 27.5 31.9 1.8 37.1 27.5 31.9 2 37.5 27.1 314 5 329 165 -2.5 0 -2.6 -2.6 03/09/2006 18:20:00 31.6 1.9 35.9 26.3 31.6 1.9 36.3 26.3 32.1 2.4 39 25.2 316 6 318 165 -2.6 0 -2.6 -2.8 03/09/2006 18:30:00 30.8 1.9 37.1 26 30.8 2 37.5 26.3 30.6 2 35.2 25.2 313 5 307 165 -2.8 0 -2.6 -3 03/09/2006 18:40:00 30.9 2 35.2 24.8 30.9 2.1 35.2 24.4 30.5 2.3 36.7 23.3 311 5 317 165 -2.9 0 -2.8 -3 03/09/2006 18:50:00 30.9 2.2 34.4 25.2 31 2.2 34.8 25.2 30.6 2.3 34.8 22.9 311 5 307 165 -2.8 0 -2.6 -3 03/09/2006 19:00:00 31.6 1.6 34.8 26.8 31.6 1.7 35.2 26.3 31.1 1.8 35.5 24 310 5 308 165 -2.8 0 -2.6 -3 03/09/2006 19:10:00 30.8 1.6 37.1 26.3 30.9 1.7 36.7 26.3 30.4 1.8 34 25.6 310 5 307 165 -3 0 -2.8 -3 03/09/2006 19:20:00 32.1 1.9 36.7 26.8 32.1 2 37.1 26.3 31.7 2.2 37.1 25.6 310 4 310 165 -3.1 0 -3 -3.3 03/09/2006 19:30:00 31.9 2.1 36.7 26.3 32 2.2 36.3 26.3 31.4 2.4 35.9 24 310 5 307 165 -3.2 0 -3 -3.5 03/09/2006 19:40:00 32.7 1.8 36.7 27.1 32.7 1.9 36.7 26.8 32.2 2 36.3 26.3 309 5 309 165 -3.1 0 -3 -3.3 03/09/2006 19:50:00 32.7 1.5 35.9 27.1 32.7 1.6 35.9 26.8 32.3 1.6 37.1 27.5 309 4 315 165 -3.2 0 -3 -3.3 03/09/2006 20:00:00 32.2 1.8 35.5 26.3 32.2 1.9 35.5 26.3 31.7 2.2 35.5 24.8 310 5 310 165 -3.2 0 -3 -3.3 03/09/2006 20:10:00 32.3 1.7 36.3 27.5 32.3 1.8 37.1 27.5 31.6 2.1 36.7 24.8 309 5 307 165 -3.2 0 -2.8 -3.3 03/09/2006 20:20:00 31.9 2.3 37.1 25.6 31.9 2.4 37.1 26.3 31.8 2.6 37.5 24.4 313 5 311 165 -3.1 0 -2.8 -3.3 03/09/2006 20:30:00 31.4 1.9 36.7 26 31.4 2 36.3 26 31.1 2 36.3 23.3 312 5 305 165 -3.2 0 -3 -3.3 03/09/2006 20:40:00 31.6 2 36.3 24.4 31.6 2.2 36.7 24.4 31.2 2.2 36.3 24.4 311 5 304 165 -3.3 0 -3 -3.5 03/09/2006 20:50:00 31.6 1.8 35.5 26.3 31.6 1.9 35.9 26.3 31.4 2.1 36.3 24.8 312 5 307 165 -3.1 0 -2.8 -3.3 03/09/2006 21:00:00 30.6 1.9 34.8 25.2 30.5 2.1 34.8 25.6 30.3 2.2 35.5 24.8 312 5 307 165 -3.1 0 -2.8 -3.3 03/09/2006 21:10:00 29.3 1.9 34.4 24.8 29.2 1.9 33.6 24.4 29.3 2 34.4 23.7 315 6 317 165 -3.2 0 -3 -3.3 03/09/2006 21:20:00 28.5 1.9 32.9 22.9 28.5 2 33.2 22.6 28.5 2.2 32.9 22.6 315 6 310 165 -3.3 0 -3 -3.5 03/09/2006 21:30:00 28.3 1.7 32.4 24 28.3 1.7 32.4 23.7 28.1 1.7 32.9 24 315 6 313 165 -3.4 0 -3.3 -3.5 03/09/2006 21:40:00 30.1 2.1 36.3 24.8 30.1 2.1 36.7 24.8 30.3 2.3 36.3 24.4 315 5 314 165 -3.2 0 -2.8 -3.5 03/09/2006 21:50:00 28.2 1.7 32.1 23.3 28.1 1.7 32.1 22.6 28 1.8 32.9 22.9 314 6 321 165 -3.2 0 -3 -3.5 03/09/2006 22:00:00 28.3 2.1 32.4 22.1 28.2 2.2 32.4 22.9 28 2.1 32.9 22.6 314 5 310 165 -3.2 0 -2.8 -3.3 03/09/2006 22:10:00 29.1 2.2 34 22.6 29.1 2.3 34 22.6 28.7 2.2 33.6 22.9 312 6 308 165 -3.1 0 -2.8 -3.3 03/09/2006 22:20:00 29.1 2 33.2 22.6 29 2 33.2 22.6 28.5 2.2 33.2 22.1 312 5 304 165 -3.2 0 -3 -3.3 03/09/2006 22:30:00 29.2 1.7 33.6 24.8 29.2 1.7 33.6 24.4 29.1 1.9 34.8 24 313 5 316 165 -3.2 0 -2.8 -3.3 03/09/2006 22:40:00 28.2 1.9 32.9 23.3 28.2 2 32.9 23.7 28 1.9 34 22.9 313 5 309 165 -3.2 0 -3 -3.3 03/09/2006 22:50:00 29.5 1.7 33.6 24 29.5 1.8 34 23.3 29 1.8 33.2 23.7 310 5 305 165 -3 0 -2.8 -3.3 03/09/2006 23:00:00 28.8 1.8 33.6 23.3 28.8 1.9 34 23.7 28.4 2.1 33.2 23.3 312 5 307 165 -3 0.1 -2.8 -3.3 03/09/2006 23:10:00 28.1 1.8 33.2 24 28.1 1.8 32.9 23.7 27.6 2 32.4 21 312 5 305 165 -3.1 0 -2.8 -3.3 03/09/2006 23:20:00 28.7 1.8 33.6 24 28.7 1.8 34 24 27.9 1.7 32.4 23.3 309 5 307 165 -3 0 -2.8 -3 03/09/2006 23:30:00 29.1 1.6 33.6 24 29 1.6 32.9 23.7 28.5 1.6 32.4 24 310 5 306 165 -2.9 0 -2.8 -3 03/09/2006 23:40:00 28.9 1.5 33.2 24.8 28.9 1.5 33.2 24.4 28.7 1.7 33.2 22.1 312 4 312 165 -2.8 0 -2.6 -3 03/09/2006 23:50:00 28.6 2.2 32.9 21.8 28.6 2.2 33.2 21.4 28.4 2.5 33.2 20.2 314 5 311 165 -2.9 0 -2.6 -3 03/10/2006 00:00:00 28.3 2.4 33.2 21 28.3 2.4 33.2 21 27.8 2.5 33.6 18.7 313 5 309 165 -2.8 0 -2.6 -2.8 03/10/2006 00:10:00 27.5 2.2 33.2 21 27.4 2.2 32.4 21 26.6 2.4 32.4 21 312 6 301 165 -2.5 0.1 -2.1 -2.8 03/10/2006 00:20:00 27 2.2 33.6 19.9 27 2.2 33.6 19.9 26.3 2.4 31.8 17.6 311 6 320 165 -2.4 0 -2.1 -2.6 03/10/2006 00:30:00 25.8 2.1 30.6 18.7 25.7 2.1 30.6 19.1 24.9 2.3 30.2 19.1 312 6 307 165 -2.5 0 -2.1 -2.6 03/10/2006 00:40:00 25.6 2 33.2 20.2 25.5 2 32.9 19.9 23.9 2.2 32.4 18.3 308 5 312 165 -2.4 0 -2.1 -2.6 03/10/2006 00:50:00 22.6 1.8 26.8 17.6 22.5 1.8 27.1 17.2 19.3 2.2 24.4 14.9 304 5 304 165 -2.4 0.1 -1.9 -2.6 03/10/2006 01:00:00 23.4 2.3 28.3 15.6 23.2 2.2 27.5 15.6 20.7 2.4 25.6 14.5 306 6 310 165 -2 0.1 -1.7 -2.1 03/10/2006 01:10:00 23.4 1.7 27.9 17.9 23.3 1.7 27.5 18.3 22.4 2.2 27.9 15.3 312 5 312 165 -2.3 0.2 -1.9 -2.8 03/10/2006 01:20:00 22 1.7 26 16.1 21.7 1.6 26 16.8 19.6 2 24.4 13 308 6 314 165 -2.7 0 -2.6 -2.8 03/10/2006 01:30:00 21.5 2.2 27.1 15.6 21.3 2.1 27.1 15.6 18.5 2.3 24.8 11.5 306 7 298 165 -2.5 0.1 -2.1 -2.8 03/10/2006 01:40:00 18.8 2.2 24.4 13.7 18.7 2.1 23.7 13.3 16.4 2.4 24.4 9.5 309 8 302 165 -2 0.1 -1.9 -2.6 03/10/2006 01:50:00 20.2 2.4 26 12.2 20.1 2.4 26 12.2 18.8 2.4 24 11.5 312 6 311 165 -2 0 -1.7 -2.4 03/10/2006 02:00:00 17.2 2.2 21.8 9.5 17.1 2.1 21.8 10.3 16 2.6 21 8.8 314 7 312 165 -2.5 0.1 -2.1 -2.8 03/10/2006 02:10:00 16.2 2.3 23.3 10.7 16.1 2.2 22.6 10.3 14.2 2.4 20.6 6.8 310 9 298 165 -2.6 0 -2.6 -2.8 03/10/2006 02:20:00 14.5 1.9 19.9 9.1 14.4 1.9 19.5 8.8 12.7 2.3 20.6 6.8 309 8 308 165 -2.6 0 -2.6 -2.8 03/10/2006 02:30:00 13.5 1.5 16.8 9.5 13.4 1.5 16.8 9.5 11.8 1.9 16.4 6.5 309 8 316 165 -2.6 0.1 -2.4 -2.8 03/10/2006 02:40:00 13.1 2.3 20.6 7.2 13.2 2.3 19.9 6.8 11.8 2.8 20.6 4.6 317 10 329 165 -2.4 0 -2.1 -2.6 03/10/2006 02:50:00 12.4 2.2 18.3 7.2 12.3 2.3 18.7 6.5 10.7 2.2 16.8 5.3 320 17 312 165 -2.2 0 -2.1 -2.6 03/10/2006 03:00:00 12.3 2.3 19.1 7.6 12.3 2.2 19.5 7.6 11.2 2.6 18.3 5.7 317 12 316 165 -2 0 -1.9 -2.1 03/10/2006 03:10:00 12 2 19.5 6.8 11.8 2.1 18.7 6.1 11.2 2 16.4 7.2 322 13 303 165 -2 0 -1.9 -2.1 03/10/2006 03:20:00 9.4 1.5 13.7 5.7 9.3 1.5 14.1 5.7 8.6 1.6 12.2 4.6 317 11 304 165 -2.4 0.1 -2.1 -2.6 03/10/2006 03:30:00 9.8 1.5 13.7 6.5 9.6 1.5 13.7 6.1 9.1 1.5 13.7 5.3 317 10 308 165 -2.4 0 -2.1 -2.6 03/10/2006 03:40:00 10.3 1.8 16.1 4.9 10.1 1.8 16.4 4.2 9.6 1.9 15.6 5.3 323 17 339 165 -2.4 0 -2.1 -2.6 03/10/2006 03:50:00 8.9 1.5 14.9 3.8 8.7 1.5 14.9 3.8 8.2 1.5 11.8 4.2 313 13 294 165 -2.2 0 -1.9 -2.6 03/10/2006 04:00:00 8.3 1.7 13.3 4.9 8.2 1.7 13.3 4.6 7 1.5 11.1 4.2 306 10 316 165 -2.4 0.1 -2.1 -2.6 03/10/2006 04:10:00 7.1 1.2 9.9 4.2 6.9 1.2 10.3 3.4 6.2 1.2 9.1 2.6 311 17 290 165 -2.5 0 -2.1 -2.6 03/10/2006 04:20:00 6.8 1.5 11.1 3 6.6 1.7 10.7 2.3 6.5 1.6 11.8 3 321 15 328 165 -2.3 0.1 -1.9 -2.6 03/10/2006 04:30:00 6.2 1.3 9.5 2.6 5.5 1.6 9.5 1.5 6.1 1.2 9.5 3.4 356 29 303 165 -2.7 0.3 -2.1 -3.3 03/10/2006 04:40:00 5.4 0.8 7.6 3 4.3 1.2 7.2 1.1 5.3 0.9 7.2 3 6 15 10 165 -2.9 0.2 -2.6 -3.3 03/10/2006 04:50:00 6.4 1.2 11.1 3.8 5.1 1.5 10.7 1.9 6.5 1.3 12.2 4.2 0 12 16 165 -3.1 0.2 -2.6 -3.5 03/10/2006 05:00:00 7.8 1 10.7 4.6 5.9 1.5 9.9 3 7.9 1.1 10.3 3.8 359 11 351 165 -3.7 0 -3.5 -3.9 03/10/2006 05:10:00 8.7 1.2 12.6 6.1 6.8 2.4 13 3.4 8.6 1.3 12.6 5.7 352 9 340 165 -4.2 0.1 -3.7 -4.6 03/10/2006 05:20:00 10.8 1 13.7 8.4 11 1.1 14.1 8.4 10.7 1 13.3 7.2 339 5 340 165 -4.2 0 -3.9 -4.4 03/10/2006 05:30:00 12 1 14.9 9.1 12.2 1 15.3 9.5 11.9 0.9 14.9 9.1 338 4 334 165 -4.3 0 -3.9 -4.4 03/10/2006 05:40:00 11.9 1.2 15.3 8.8 12 1.5 16.1 7.6 11.5 1.2 15.3 8.8 342 5 336 165 -4.5 0 -4.4 -4.6 03/10/2006 05:50:00 9.6 1.5 14.1 6.5 9.2 1.7 14.1 4.9 8.5 1.7 12.6 4.2 341 8 340 165 -4.6 0 -4.4 -4.8 03/10/2006 06:00:00 9 1.2 12.2 6.1 8.6 1.5 11.8 3.8 7.9 1.5 11.1 3.8 344 7 353 165 -4.7 0 -4.6 -4.8 03/10/2006 06:10:00 10 1.1 13.3 7.2 9.7 1.5 14.1 5.7 9.1 1.1 11.8 5.7 342 7 341 165 -4.8 0 -4.6 -5 03/10/2006 06:20:00 10.5 1 13.7 8 10.3 1.3 14.5 5.7 9.9 1 12.6 7.2 343 6 348 165 -4.7 0 -4.6 -4.8 03/10/2006 06:30:00 9.8 1.5 13.3 5.7 8.9 1.7 13.3 4.9 9.2 1.5 13.3 5.7 346 6 352 165 -4.8 0 -4.6 -5 03/10/2006 06:40:00 9.1 1.1 11.8 5.7 8.1 1.7 11.8 3.8 8.6 1.2 11.5 4.9 347 9 339 165 -4.8 0 -4.6 -5 03/10/2006 06:50:00 10 1.2 13 6.5 9 1.7 13 4.6 9.3 1.3 13 5.7 347 8 339 165 -4.8 0 -4.6 -5 03/10/2006 07:00:00 10.3 1.3 13.3 6.5 10.1 1.5 13.7 6.1 9.3 1.5 13 5.3 340 7 345 165 -4.8 0 -4.6 -5 03/10/2006 07:10:00 9.5 1.3 13 5.7 9.2 1.5 13.3 5.3 8.8 1.3 12.6 4.6 340 9 344 165 -4.8 0 -4.6 -5 03/10/2006 07:20:00 8.4 1 11.8 4.6 8 1.3 12.2 3.4 7.5 1.1 10.3 3.8 343 8 343 165 -4.8 0 -4.6 -5 03/10/2006 07:30:00 7.8 1.2 11.1 4.2 7.6 1.3 11.1 3.8 6.6 1.5 9.9 1.5 332 14 340 165 -4.9 0 -4.6 -5 03/10/2006 07:40:00 4.4 1.5 7.6 0.7 4 1.7 7.6 0.4 3.2 1.6 7.2 0.4 321 21 358 165 -4.8 0 -4.6 -5 03/10/2006 07:50:00 5.1 1.3 8 0.7 4.4 1.3 7.6 0.4 4 1.4 6.8 0.4 335 22 9 165 -4.7 0 -4.6 -5 03/10/2006 08:00:00 6.8 1 9.1 4.2 5.6 1.7 9.5 2.6 6.2 1.2 9.1 2.6 352 10 352 165 -4.5 0.1 -4.2 -4.6 03/10/2006 08:10:00 7.7 1.3 11.8 5.3 7.1 2.1 12.2 3 7.2 1.3 10.7 4.6 341 10 339 165 -4.1 0 -3.7 -4.4 03/10/2006 08:20:00 7.6 1.2 11.1 4.6 6.8 1.7 11.1 3.4 6.4 1.5 10.7 2.6 345 9 347 165 -3.9 0 -3.7 -3.9 03/10/2006 08:30:00 7.3 1.2 10.7 3.4 5.9 1.4 9.9 2.6 6.6 1.5 10.3 1.9 351 9 347 165 -3.6 0 -3.3 -3.7 03/10/2006 08:40:00 6.5 1.2 9.9 3.4 6.1 1.6 10.3 1.9 5.7 1.5 9.5 1.5 336 13 340 165 -3.3 0.2 -3 -3.5 03/10/2006 08:50:00 7.3 1.6 11.1 3.8 6.9 1.7 10.7 3 6.6 1.7 10.3 2.6 337 13 351 165 -2.8 0 -2.6 -3.3 03/10/2006 09:00:00 8.5 1.3 11.8 4.9 7.5 1.5 11.8 4.2 7.8 1.5 11.1 4.2 345 10 332 165 -2.9 0 -2.8 -3 03/10/2006 09:10:00 7.1 1.3 10.3 3 6.2 1.4 9.1 2.3 6.4 1.3 9.9 2.6 345 12 350 165 -2.8 0 -2.6 -3 03/10/2006 09:20:00 5.9 1.7 9.5 1.5 5.2 1.5 8.8 0.7 4.6 1.6 8.8 0.7 338 22 348 165 -2.2 0.1 -1.9 -2.8 03/10/2006 09:30:00 4.9 1 8.4 2.3 4.5 1.2 8 1.5 4.5 0.9 7.6 1.9 332 16 325 165 -1.8 0 -1.4 -2.1 03/10/2006 09:40:00 5.9 1.2 10.3 3 5.7 1.3 10.3 2.6 5.5 1 8.4 3 320 15 330 165 -1.9 0.2 -1.4 -2.1 03/10/2006 09:50:00 5.9 1.1 9.9 2.6 5.6 1.1 9.5 2.6 5.7 1.1 9.5 3.4 333 16 328 165 -2 0 -1.9 -2.1 03/10/2006 10:00:00 5.3 1.5 8.8 1.9 5.2 1.5 9.1 1.1 4.8 1.4 7.6 1.5 317 21 302 165 -2 0.3 -1.4 -2.6 03/10/2006 10:10:00 3.4 1.5 7.2 0.4 3.2 1.6 7.2 0.4 2.7 1.4 6.5 0.4 312 51 305 165 -0.9 0.3 -0.3 -1.7 03/10/2006 10:20:00 1.8 1.2 4.9 0.4 1.7 1.2 4.6 0.4 2 1.1 5.3 0.4 359 102 57 165 -0.7 0.3 -0.3 -1.4 03/10/2006 10:30:00 1.5 0.8 3.4 0.4 1.4 0.8 3.4 0.4 1.7 0.9 4.2 0.4 8 94 58 165 -0.7 0.2 -0.3 -1.2 03/10/2006 10:40:00 1.3 1 3.8 0.4 1.3 0.9 3.4 0.4 1.4 1 3.4 0.4 201 49 209 165 -0.2 0.3 0.2 -0.8 03/10/2006 10:50:00 2.4 0.8 4.2 0.4 2.1 0.7 3.8 0.4 2.5 0.7 4.2 0.4 148 35 165 165 0 0.2 0.7 -0.5 03/10/2006 11:00:00 4.4 2.6 9.1 0.4 4.5 2.5 8.8 0.4 3.9 2.2 8 0.4 267 53 293 165 -0.4 0.7 0.4 -1.9 03/10/2006 11:10:00 7.5 1.1 10.3 4.6 7.5 1 9.9 4.2 6.1 1.1 9.1 3.8 296 8 302 165 -2.1 0 -1.7 -2.4 03/10/2006 11:20:00 8.2 1.1 12.6 5.7 8.1 1.1 11.8 5.3 6.7 1.1 9.9 4.2 303 8 305 165 -1.9 0.1 -1.7 -2.1 03/10/2006 11:30:00 8 1.1 11.1 5.3 7.8 1.3 10.7 4.2 7.3 1 9.5 4.6 321 19 309 165 -1.1 0.6 0.2 -1.9 03/10/2006 11:40:00 8.3 1.5 12.2 4.6 7.7 1.5 12.2 3.8 8 1.6 12.6 4.9 338 14 332 165 0.3 0.1 0.7 -0.1 03/10/2006 11:50:00 12.2 1.9 16.8 7.6 11 2.5 16.4 5.7 11.7 2 16.4 6.8 346 9 344 165 0.6 0.1 0.9 0.2 03/10/2006 12:00:00 10.2 1.3 13.7 6.5 7.8 1.6 13 4.2 9.7 1.4 13.3 5.7 355 9 2 165 1.4 0.1 1.6 0.9 03/10/2006 12:10:00 11 1.7 15.3 7.6 9.6 2.4 14.9 4.2 11 1.8 16.1 7.2 348 8 351 165 1.5 0 1.8 1.4 03/10/2006 12:20:00 6.8 1.3 9.5 3.4 5.6 1.5 9.9 2.6 6.5 1.2 9.5 3.8 357 15 345 165 2.1 0.2 2.6 1.6 03/10/2006 12:30:00 7.8 1.1 9.9 3.8 5.9 1.4 9.9 2.3 7.5 1.1 9.9 4.2 0 9 8 165 2.2 0 2.3 1.8 03/10/2006 12:40:00 6 1.5 10.7 3 4.9 1.7 10.7 1.9 5.7 1.6 10.7 2.3 352 14 7 165 2.4 0.1 2.8 2.1 03/10/2006 12:50:00 6.4 1.4 9.5 3.4 6 1.8 10.3 2.3 5.9 1.3 9.1 3 343 12 345 165 2.5 0.3 2.8 1.8 03/10/2006 13:00:00 6 1.3 9.9 3 5.1 1.7 10.3 1.5 5.8 1.4 9.5 3 339 29 345 165 1.9 0.5 2.6 0.2 03/10/2006 13:10:00 7.2 1.6 10.3 2.6 7.2 1.7 11.5 2.6 6.9 1.9 11.1 2.3 296 19 277 165 0.1 0.2 0.7 -0.3 03/10/2006 13:20:00 6 2.1 10.7 0.4 5.7 2.1 10.7 0.4 5.7 2 10.7 1.9 318 29 348 165 0.7 0.2 0.9 0.2 03/10/2006 13:30:00 5.7 2.2 11.8 1.9 5.5 2.1 11.5 1.9 5.2 2.1 11.5 1.9 318 23 352 165 0.9 0.1 1.4 0.7 03/10/2006 13:40:00 4.1 1.7 8 0.4 4.1 1.8 8.4 0.4 4 1.5 8.4 0.7 291 56 249 165 0.9 0.1 1.4 0.7 03/10/2006 13:50:00 6.3 1.2 9.5 2.3 6.9 1.5 10.3 2.6 6.9 1.5 10.3 3.4 264 17 250 165 0.4 0.2 0.9 -0.1 03/10/2006 14:00:00 6.1 1.4 10.3 3 7 1.6 10.3 3 7 1.6 9.9 3 262 17 238 165 0.4 0.1 0.7 -0.1 03/10/2006 14:10:00 5.8 1.7 9.9 1.1 5.8 1.7 9.5 1.1 5.6 1.6 9.1 2.3 308 30 332 165 0.7 0.2 1.1 0.2 03/10/2006 14:20:00 6.8 1.9 11.5 1.1 6.8 1.9 11.5 0.7 6.5 1.7 12.2 2.3 296 29 286 165 0.8 0.1 1.4 0.7 03/10/2006 14:30:00 6.2 1.6 15.3 3 5.8 1.8 13.3 2.3 6 1.3 11.5 3 328 32 307 165 0.9 0.3 1.4 0.4 03/10/2006 14:40:00 8.2 1.1 11.5 4.6 8.1 1.1 11.5 4.6 7.8 1.3 11.1 4.2 308 19 284 165 0.2 0.2 0.7 -0.1 03/10/2006 14:50:00 6.3 0.8 9.5 4.6 6.1 0.8 9.1 3.4 6 0.6 8.4 4.6 328 13 299 165 0.7 0.5 1.6 -0.1 03/10/2006 15:00:00 5.6 0.7 6.8 3.4 5.5 0.8 7.2 3 5.5 0.8 6.8 3.4 333 9 339 165 1.6 0.1 1.8 1.4 03/10/2006 15:10:00 5.4 0.7 6.8 3 5.2 0.6 6.5 3 5.2 0.7 6.5 3.4 328 11 351 165 1.2 0.3 1.8 0.9 03/10/2006 15:20:00 6.4 0.6 8 4.9 5.9 1.2 7.6 2.6 6.2 0.7 7.6 4.2 341 9 335 165 1.3 0 1.6 1.1 03/10/2006 15:30:00 4.8 1.5 7.2 0.4 4.1 1.5 7.6 0.4 4.3 1.7 6.8 0.4 340 21 345 165 1.5 0 1.8 1.4 03/10/2006 15:40:00 4 0.7 5.7 2.3 3.1 0.8 5.3 1.1 3.7 0.7 5.7 2.3 347 12 355 165 1.4 0 1.6 1.4 03/10/2006 15:50:00 6.1 1 9.1 4.6 5.9 1 9.1 4.2 6 1 9.1 3.4 326 13 341 165 1 0.2 1.4 0.7 03/10/2006 16:00:00 7.3 1 9.5 4.9 7.2 1 9.9 4.6 7.2 0.9 9.1 4.9 333 7 339 165 0.4 0.2 0.9 0.2 03/10/2006 16:10:00 5.5 0.7 7.6 4.2 5.4 0.7 7.2 3.8 5.2 0.8 6.8 3 317 11 323 165 0.1 0 0.2 -0.1 03/10/2006 16:20:00 5.2 0.6 6.8 3.8 5.1 0.7 6.5 3.4 4.6 0.8 6.8 2.6 304 13 310 165 -0.3 0.1 0.2 -0.5 03/10/2006 16:30:00 5 0.5 6.8 3.4 4.9 0.5 6.5 3.4 4.1 0.7 6.5 2.6 299 9 302 165 -0.5 0 -0.3 -0.5 03/10/2006 16:40:00 5.1 0.8 6.8 3.4 4.9 0.8 6.8 3 4.3 0.6 6.5 3 302 11 298 165 -0.5 0 -0.3 -0.5 03/10/2006 16:50:00 5.7 0.6 7.6 4.2 5.5 0.7 7.2 3.8 4.6 0.7 7.6 3 301 6 294 165 -0.5 0 -0.5 -0.8 03/10/2006 17:00:00 5.6 0.8 8 4.2 5.5 0.9 7.6 3.8 4.7 0.8 7.2 3 302 8 295 165 -0.5 0 -0.3 -0.8 03/10/2006 17:10:00 6.1 1.2 8.8 3 6 1.2 8.4 3 5.2 1 8 3 304 9 312 165 -0.6 0 -0.5 -0.8 03/10/2006 17:20:00 9 1.1 11.8 6.1 8.9 1.1 11.5 5.7 7.4 1.2 10.7 4.9 305 8 301 165 -0.9 0 -0.5 -1 03/10/2006 17:30:00 6.9 2.2 10.7 2.6 6.7 2.3 11.1 2.3 6.4 1.9 11.1 2.6 318 14 308 165 -0.9 0 -0.8 -1 03/10/2006 17:40:00 4.9 0.7 7.2 3.4 4.7 0.7 6.8 3 4.9 0.7 7.2 3 329 9 334 165 -0.9 0 -0.8 -1 03/10/2006 17:50:00 4.7 0.5 5.7 3.4 4.4 0.5 5.7 2.6 4.8 0.5 6.1 3.8 324 9 334 165 -1 0 -0.8 -1.2 03/10/2006 18:00:00 4.4 0.6 5.7 2.6 4.2 0.7 5.3 1.9 4.4 0.6 5.7 2.3 337 7 328 165 -1.2 0 -1.2 -1.4 03/10/2006 18:10:00 3.7 1.2 6.5 0.7 2.6 0.8 4.6 0.4 4.1 1.3 6.8 0.7 347 15 358 165 -1.3 0 -1.2 -1.4 03/10/2006 18:20:00 2.8 1.1 5.7 0.4 2.6 1.2 5.7 0.4 2.3 1 4.6 0.4 280 27 296 165 -1.1 0.1 -0.8 -1.4 03/10/2006 18:30:00 4.5 0.7 6.5 3 4.3 0.8 6.5 2.6 3.6 0.5 5.3 2.3 302 6 298 165 -1.2 0 -1 -1.4 03/10/2006 18:40:00 5.1 0.7 6.8 3 4.9 0.7 6.5 3 4.1 0.6 5.7 2.6 301 8 302 165 -1.2 0 -1.2 -1.4 03/10/2006 18:50:00 4.8 0.5 6.1 3 4.6 0.5 5.7 3 4.3 0.5 5.3 3 311 13 302 165 -1.3 0 -1.2 -1.4 03/10/2006 19:00:00 4.7 0.5 5.7 3.4 4.5 0.5 5.7 3 4.8 0.4 6.1 3.4 331 11 321 165 -1.5 0 -1.4 -1.7 03/10/2006 19:10:00 5.4 0.7 7.2 3.8 3.9 1 6.8 1.9 5.7 0.7 7.2 4.2 352 6 348 165 -1.9 0.1 -1.4 -2.1 03/10/2006 19:20:00 5.1 0.7 6.8 3 3.6 0.9 6.8 2.3 5.5 0.6 6.8 3.8 357 8 357 165 -2 0 -1.9 -2.1 03/10/2006 19:30:00 4.9 0.8 6.5 2.6 3.8 0.9 6.5 2.3 5.1 0.8 6.8 3.4 349 9 351 165 -2.1 0 -1.9 -2.1 03/10/2006 19:40:00 4.9 0.7 6.5 2.6 4.7 0.8 6.1 2.3 4.7 0.6 6.1 3 314 9 309 165 -1.9 0 -1.7 -2.1 03/10/2006 19:50:00 4.4 0.6 5.7 3 4 0.8 5.7 1.5 4.4 0.5 5.3 3 325 15 309 165 -1.8 0.1 -1.4 -1.9 03/10/2006 20:00:00 4.6 0.6 6.1 1.9 4.3 0.6 6.1 1.5 4.3 0.5 5.7 2.6 316 14 330 165 -1.8 0 -1.7 -2.1 03/10/2006 20:10:00 4.9 0.7 6.5 3.4 4.6 0.7 6.1 3 4.4 0.6 5.7 2.6 308 7 304 165 -1.8 0 -1.7 -1.9 03/10/2006 20:20:00 4.3 0.4 5.3 3.4 3.9 0.5 5.3 1.9 4.2 0.5 5.3 3 320 11 312 165 -1.9 0.1 -1.7 -2.1 03/10/2006 20:30:00 4 0.5 5.7 3 3.7 0.6 5.3 1.9 3.8 0.4 4.6 2.3 321 15 293 165 -2.1 0 -1.9 -2.1 03/10/2006 20:40:00 4.9 0.5 6.1 3.8 4.7 0.5 6.1 3.4 4.3 0.5 5.3 3 305 8 297 165 -2.1 0 -1.9 -2.4 03/10/2006 20:50:00 4 0.7 5.7 2.6 3.8 0.7 5.3 2.6 3.8 0.6 5.3 2.6 310 5 309 165 -2.1 0 -1.9 -2.1 03/10/2006 21:00:00 4.3 0.5 5.3 3 4 0.5 4.9 2.6 3.6 0.7 4.9 2.3 304 6 305 165 -2.4 0 -2.1 -2.6 03/10/2006 21:10:00 4.7 0.4 5.7 3.8 4.5 0.4 5.7 3.8 4 0.7 5.7 2.6 300 8 289 165 -2.2 0.1 -2.1 -2.6 03/10/2006 21:20:00 3.9 0.5 4.9 2.6 3.6 0.6 4.6 2.3 3.4 0.6 4.6 1.9 306 6 302 165 -2.5 0 -2.1 -2.6 03/10/2006 21:30:00 3.5 0.5 5.3 2.3 3.1 0.5 4.9 1.5 3.4 0.4 4.6 2.3 316 7 328 165 -2.4 0 -2.1 -2.6 03/10/2006 21:40:00 2.8 0.5 4.2 1.5 2.4 0.6 3.8 1.1 2.7 0.6 4.2 1.1 307 9 304 165 -2.4 0 -2.1 -2.6 03/10/2006 21:50:00 4.2 0.6 4.9 1.5 4.1 0.6 5.3 1.1 4.4 0.8 5.7 2.6 287 5 291 165 -2.4 0 -2.1 -2.6 03/10/2006 22:00:00 3.9 0.8 5.3 2.3 4.1 0.5 5.3 3 4.3 0.4 5.3 3.4 271 8 284 165 -2.4 0 -2.1 -2.6 03/10/2006 22:10:00 3.5 0.5 4.9 2.3 3.2 0.6 4.9 1.9 3.1 0.6 5.3 1.9 305 8 279 165 -2.3 0 -2.1 -2.6 03/10/2006 22:20:00 2.7 0.4 3.8 1.9 2.2 0.5 3.4 0.7 2.7 0.3 3.4 1.9 330 17 301 165 -2.2 0 -2.1 -2.6 03/10/2006 22:30:00 3 0.3 3.8 2.3 2.6 0.4 3.8 1.5 3 0.3 3.8 1.9 334 12 332 165 -2.4 0 -2.1 -2.6 03/10/2006 22:40:00 2.4 0.4 3.4 1.1 1.4 0.8 3 0.4 2.3 0.4 3 1.5 348 20 312 165 -2.5 0 -2.4 -2.6 03/10/2006 22:50:00 1.9 0.3 2.6 1.5 0.7 0.5 1.9 0.4 2.1 0.2 2.6 1.5 353 4 351 165 -2.4 0.1 -1.9 -2.6 03/10/2006 23:00:00 1.8 0.3 2.3 1.1 1 0.5 2.3 0.4 2.1 0.3 2.6 1.5 347 3 351 165 -2 0 -1.7 -2.4 03/10/2006 23:10:00 2 0.3 2.6 1.5 0.9 0.3 1.5 0.4 2.2 0.2 2.6 1.5 1 10 351 165 -1.7 0 -1.4 -1.9 03/10/2006 23:20:00 1.7 0.4 2.6 0.7 0.8 0.5 2.3 0.4 1.8 0.2 2.3 1.1 14 12 29 165 -1.4 0.1 -1.2 -1.7 03/10/2006 23:30:00 1.2 0.3 1.9 0.4 0.4 0.2 1.1 0.4 1.4 0.3 2.3 0.7 18 9 10 165 -1.2 0 -1 -1.4 03/10/2006 23:40:00 0.9 0.6 1.9 0.4 0.6 0.3 1.1 0.4 1.1 0.4 1.9 0.4 84 29 43 165 -0.9 0 -0.8 -1.2 03/10/2006 23:50:00 0.5 0.3 1.5 0.4 0.4 0 0.4 0.4 0.7 0.3 1.5 0.4 121 4 118 165 -1.2 0 -1 -1.4 03/11/2006 00:00:00 0.8 0.4 1.9 0.4 0.4 0.1 1.1 0.4 1 0.4 1.9 0.4 139 13 160 165 -1.4 0 -1.2 -1.4 03/11/2006 00:10:00 2 0.3 2.6 1.5 1.3 0.4 1.9 0.7 2.1 0.3 2.6 1.5 143 13 160 165 -1.6 0 -1.2 -1.9 03/11/2006 00:20:00 1.8 0.3 2.3 1.1 1.1 0.3 1.5 0.4 1.9 0.2 2.3 1.5 131 2 131 165 -1.7 0 -1.7 -1.9 03/11/2006 00:30:00 1.4 0.3 1.9 0.7 0.6 0.3 1.1 0.4 1.4 0.4 2.3 0.4 133 7 129 165 -1.7 0 -1.7 -1.9 03/11/2006 00:40:00 1.1 0.6 2.3 0.4 0.5 0.3 1.5 0.4 1.2 0.6 2.3 0.4 130 7 128 165 -1.7 0 -1.4 -1.9 03/11/2006 00:50:00 0.8 0.5 1.9 0.4 0.4 0 0.4 0.4 1 0.4 1.9 0.4 157 11 162 165 -1.8 0 -1.7 -1.9 03/11/2006 01:00:00 0.4 0 0.7 0.4 0.4 0 0.4 0.4 0.5 0.2 1.1 0.4 164 0 163 165 -1.9 0 -1.7 -1.9 03/11/2006 01:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0.1 0.7 0.4 164 0 165 165 -1.6 0 -1.4 -1.9 03/11/2006 01:20:00 0.5 0.3 1.1 0.4 0.4 0 0.4 0.4 0.9 0.4 1.5 0.4 64 49 43 165 -1.6 0 -1.4 -1.7 03/11/2006 01:30:00 0.8 0.6 2.3 0.4 0.5 0.3 1.9 0.4 0.9 0.5 2.3 0.4 55 13 74 165 -1.6 0.1 -1.4 -1.9 03/11/2006 01:40:00 1.8 0.3 2.3 1.1 1.2 0.4 1.9 0.4 1.9 0.2 2.6 1.5 63 5 65 165 -1.5 0 -1.4 -1.7 03/11/2006 01:50:00 1.6 0.3 2.3 1.1 0.8 0.4 1.5 0.4 1.8 0.2 2.3 1.1 48 8 56 165 -1.6 0 -1.4 -1.7 03/11/2006 02:00:00 1.4 0.3 1.9 0.4 0.6 0.3 1.5 0.4 1.6 0.2 2.3 1.1 38 5 35 165 -1.6 0 -1.4 -1.7 03/11/2006 02:10:00 1.7 0.5 2.6 0.4 1.1 0.5 2.3 0.4 1.7 0.4 2.6 0.7 66 15 65 165 -1.6 0 -1.4 -1.9 03/11/2006 02:20:00 0.5 0.3 1.5 0.4 0.4 0 0.7 0.4 0.7 0.3 1.5 0.4 116 9 130 165 -1.7 0 -1.4 -1.9 03/11/2006 02:30:00 1.9 0.6 3 0.4 1.5 0.7 3 0.4 1.8 0.6 3 0.7 77 11 81 165 -1.8 0 -1.7 -1.9 03/11/2006 02:40:00 3 0.4 3.8 1.9 2.7 0.5 3.8 1.5 2.6 0.4 3.4 1.5 73 11 65 165 -1.8 0 -1.7 -1.9 03/11/2006 02:50:00 2.2 1.1 4.2 0.4 1.8 1.2 3.8 0.4 2.1 0.9 3.8 0.4 81 14 71 165 -1.7 0 -1.4 -1.9 03/11/2006 03:00:00 2.2 0.5 3.4 1.1 1.7 0.6 3.4 0.4 2.1 0.5 3 0.7 81 8 78 165 -1.6 0 -1.4 -1.9 03/11/2006 03:10:00 2.4 0.8 3.8 0.4 2 1 3.8 0.4 2.3 0.7 3.8 1.1 77 10 81 165 -1.5 0 -1.4 -1.7 03/11/2006 03:20:00 3.2 0.3 4.2 2.6 3 0.3 3.8 2.3 3.1 0.3 3.8 2.3 81 4 80 165 -1.6 0 -1.4 -1.7 03/11/2006 03:30:00 3.1 0.2 3.8 2.6 2.9 0.2 3.4 2.3 3 0.2 3.8 2.6 81 4 80 165 -1.4 0 -1.2 -1.4 03/11/2006 03:40:00 3.3 0.2 3.8 2.6 3 0.3 3.8 2.3 3.2 0.3 3.8 2.3 85 2 84 165 -1.2 0 -0.8 -1.4 03/11/2006 03:50:00 3.5 0.3 4.2 2.6 3.3 0.3 3.8 2.6 3.5 0.3 4.2 3 84 4 85 165 -0.9 0 -0.8 -1.2 03/11/2006 04:00:00 4.1 0.3 4.6 3.4 4 0.3 4.6 3 3.9 0.3 4.6 3 77 3 75 165 -1 0 -0.8 -1.2 03/11/2006 04:10:00 4.2 0.4 4.9 3 4.1 0.4 4.9 2.6 4 0.3 4.6 3 67 6 70 165 -1 0 -1 -1.2 03/11/2006 04:20:00 3.9 0.4 4.9 3 3.7 0.4 4.9 2.6 3.6 0.3 4.6 3 64 5 65 165 -1.1 0 -0.8 -1.2 03/11/2006 04:30:00 4 0.3 4.6 3 3.8 0.4 4.6 2.6 3.7 0.4 4.6 2.6 66 5 68 165 -1.1 0 -0.8 -1.2 03/11/2006 04:40:00 4.1 0.3 4.6 3.4 4 0.3 4.6 3 3.9 0.3 4.6 3 63 4 66 165 -0.9 0 -0.8 -1.2 03/11/2006 04:50:00 4.7 0.3 5.7 4.2 4.6 0.4 5.7 3.8 4.5 0.3 5.7 3.8 56 2 59 165 -0.9 0 -0.8 -1.2 03/11/2006 05:00:00 4.6 0.4 5.3 3.4 4.4 0.4 5.3 3.4 4.1 0.4 4.9 3.4 55 4 63 165 -0.9 0 -0.8 -1 03/11/2006 05:10:00 5.3 0.5 7.6 4.2 5.2 0.6 7.6 4.2 4.8 0.5 6.8 3.8 60 7 65 165 -0.8 0 -0.5 -1 03/11/2006 05:20:00 5.8 0.6 7.2 4.2 5.8 0.7 7.6 4.2 5.4 0.6 6.8 3.4 73 8 75 165 -0.3 0.1 -0.1 -0.5 03/11/2006 05:30:00 6.4 0.6 7.6 4.6 6.5 0.6 8 4.6 6.3 0.6 7.6 4.6 87 6 91 165 0.1 0.1 0.7 -0.1 03/11/2006 05:40:00 6.1 0.7 7.6 4.2 6.1 0.8 7.6 3.8 5.9 0.8 7.6 3.8 102 5 93 165 0.3 0 0.7 0.2 03/11/2006 05:50:00 5 0.6 6.8 3.4 4.9 0.7 6.5 3 4.8 0.8 6.5 3 109 6 111 165 0.1 0 0.4 -0.1 03/11/2006 06:00:00 4.6 0.6 6.5 3.4 4.3 0.6 6.1 2.6 4.3 0.5 5.3 3 122 7 138 165 -0.1 0 0.2 -0.3 03/11/2006 06:10:00 4.7 0.4 5.7 3.8 4.5 0.5 5.7 3.4 4.5 0.4 5.7 3.4 121 6 119 165 0 0 0.2 -0.1 03/11/2006 06:20:00 5.2 0.5 6.1 3.8 5.1 0.6 6.1 3.4 5 0.5 6.1 3 124 4 128 165 0.1 0 0.2 -0.1 03/11/2006 06:30:00 5 0.6 7.2 3.8 4.9 0.6 7.2 3.8 4.8 0.6 6.8 3 121 6 126 165 0.1 0 0.2 -0.1 03/11/2006 06:40:00 5.6 0.6 6.8 4.2 5.6 0.6 6.8 4.2 5.5 0.6 6.8 3.8 126 5 126 165 0.2 0 0.2 0.2 03/11/2006 06:50:00 5.2 1.1 8 3 5.1 1.2 8 2.6 5 1 7.6 3 122 8 116 165 0.1 0 0.2 -0.1 03/11/2006 07:00:00 8.7 0.6 9.9 6.8 8.9 0.6 9.9 6.5 8.3 0.8 9.9 5.7 113 6 128 165 0.6 0.2 0.9 0.2 03/11/2006 07:10:00 8.1 0.7 9.5 5.7 8.2 0.8 9.5 5.7 8 0.7 9.1 5.7 120 3 116 165 0.6 0 0.9 0.4 03/11/2006 07:20:00 6.9 0.4 8.4 5.7 7 0.4 8.4 5.7 7 0.5 8.8 5.3 122 5 121 165 0.3 0.1 0.7 0.2 03/11/2006 07:30:00 6.7 0.5 8 5.3 6.6 0.4 8 5.3 6.5 0.4 7.6 5.3 125 3 125 165 0.2 0 0.4 0.2 03/11/2006 07:40:00 6 0.7 7.6 4.6 5.9 0.7 7.6 3.8 5.9 0.7 8 3.8 124 5 128 165 0.1 0 0.2 0.2 03/11/2006 07:50:00 7.7 0.5 9.5 6.1 7.7 0.5 9.5 6.1 7.6 0.5 8.8 6.1 125 4 122 165 0.3 0 0.7 0.2 03/11/2006 08:00:00 7.8 0.7 9.9 6.5 7.9 0.7 10.3 6.5 7.7 0.6 9.5 6.1 129 6 124 165 0.5 0 0.7 0.2 03/11/2006 08:10:00 7.7 0.8 9.9 5.7 7.7 0.8 9.9 5.7 7.6 0.8 9.9 5.3 133 7 137 165 0.5 0 0.7 0.7 03/11/2006 08:20:00 7.5 0.9 10.3 5.3 7.6 0.9 10.3 5.7 7.2 1 9.9 5.3 135 7 134 165 0.5 0 0.7 0.4 03/11/2006 08:30:00 8.2 1 11.5 5.7 8.1 1 11.1 5.7 8.1 1.2 11.1 5.3 145 9 151 165 0.7 0.1 0.9 0.4 03/11/2006 08:40:00 8.4 1.4 12.2 5.7 8.4 1.4 12.6 5.7 8.1 1.3 11.8 5.3 140 8 136 165 0.9 0.1 1.4 0.7 03/11/2006 08:50:00 10 1.3 12.2 6.8 10.1 1.3 12.2 6.1 9.9 1.3 12.6 6.1 136 9 124 165 1 0.2 1.4 0.7 03/11/2006 09:00:00 11 1 13.3 7.6 11.1 1 13.7 8 10.8 1.2 13.3 6.8 133 6 133 165 1.4 0 1.4 1.4 03/11/2006 09:10:00 11.8 1 13.7 9.1 12 1 13.7 9.1 11.8 1 14.1 8.8 133 5 127 165 1.4 0 1.6 1.4 03/11/2006 09:20:00 11 1.1 13.7 6.8 11.1 1.1 14.1 8 10.9 1.3 13.7 7.2 133 6 133 165 1.4 0 1.4 1.4 03/11/2006 09:30:00 11.5 0.8 13.7 9.1 11.7 0.8 14.1 9.1 11.4 1 14.1 8.4 133 6 128 165 1.4 0 1.6 1.4 03/11/2006 09:40:00 11.6 1.1 15.6 8.4 11.7 1.2 16.4 8.4 11.6 1.1 14.5 8.8 134 7 124 165 1.3 0 1.4 1.1 03/11/2006 09:50:00 12.3 1.2 14.9 9.5 12.4 1.2 15.3 9.9 12.2 1.3 15.3 8.8 132 6 129 165 1.3 0.1 1.6 1.1 03/11/2006 10:00:00 11.3 1.2 14.5 8.8 11.5 1.2 14.9 8.8 11.2 1.4 15.3 8 135 6 129 165 1.4 0 1.6 1.4 03/11/2006 10:10:00 12.4 1.1 14.5 9.1 12.6 1.1 15.3 9.1 12.3 1.2 14.9 8.4 134 6 128 165 1.4 0 1.6 1.4 03/11/2006 10:20:00 12.1 1 14.1 8.8 12.2 1 14.5 9.1 11.9 1.2 14.5 8.4 134 6 144 165 1.4 0 1.6 1.4 03/11/2006 10:30:00 11.8 1.1 14.9 8.8 12 1.2 14.5 8.8 11.7 1.2 14.5 8 132 7 135 165 1.4 0 1.6 1.4 03/11/2006 10:40:00 13.3 1.2 16.4 9.9 13.5 1.2 16.1 9.1 13.3 1.3 16.1 9.1 132 7 129 165 1.4 0 1.6 1.4 03/11/2006 10:50:00 12.4 1.1 15.6 8 12.6 1.1 15.6 8.8 12.3 1.2 15.6 8.8 128 5 130 165 1.3 0 1.4 1.4 03/11/2006 11:00:00 12.6 1.5 16.1 9.5 12.8 1.5 16.4 9.5 12.4 1.6 16.8 8.4 128 8 123 165 1.4 0 1.6 1.4 03/11/2006 11:10:00 12.4 1.5 15.6 8.8 12.5 1.5 16.1 8.8 12.2 1.7 16.1 8.4 124 6 128 165 1.2 0 1.4 0.9 03/11/2006 11:20:00 11.6 1 14.1 8.4 11.8 1.1 14.1 7.2 11.2 1.2 14.1 6.8 120 6 121 165 0.8 0.1 1.4 0.7 03/11/2006 11:30:00 11 1.1 14.5 8 11.2 1.1 14.9 8 10.7 1.3 14.9 7.2 123 7 125 165 0.5 0 0.7 0.4 03/11/2006 11:40:00 10.6 1 13 8 10.7 1 13.3 7.6 10.1 1 12.6 6.8 118 6 115 165 0.2 0.1 0.7 0.2 03/11/2006 11:50:00 10.7 0.7 13.3 8.4 10.9 0.7 13 8.4 10.2 1 12.6 6.8 113 5 111 165 0.1 0 0.2 -0.1 03/11/2006 12:00:00 10.7 0.8 12.6 8.4 10.8 0.8 12.6 8 10.1 1 11.8 7.2 112 6 108 165 0.1 0 0.2 -0.1 03/11/2006 12:10:00 10.8 0.9 13 7.6 11 0.9 13.3 8 10.4 0.9 12.6 7.2 109 6 109 165 0.1 0 0.2 -0.1 03/11/2006 12:20:00 11.4 0.7 12.6 9.5 11.6 0.7 13 9.5 10.9 1 13 8 111 5 119 165 0.2 0 0.4 0.2 03/11/2006 12:30:00 12.4 1 15.3 9.1 12.7 1 16.1 9.5 11.9 1.2 15.3 8 113 5 116 165 0.5 0 0.7 0.2 03/11/2006 12:40:00 12.1 0.9 14.5 9.9 12.3 1 14.5 10.3 11.5 1.1 14.1 8 117 5 121 165 0.7 0.1 0.9 0.7 03/11/2006 12:50:00 12.5 1.3 15.6 9.1 12.7 1.3 16.4 9.1 12.3 1.5 16.1 8.8 124 6 127 165 1 0 1.4 0.9 03/11/2006 13:00:00 14.2 1.5 18.3 10.7 14.4 1.5 18.7 10.7 14.1 1.5 18.7 10.3 135 6 124 165 1.2 0 1.4 1.1 03/11/2006 13:10:00 15.4 1.3 18.3 11.8 15.6 1.3 18.7 12.2 15 1.2 18.3 11.1 134 5 133 165 1.1 0 1.4 0.9 03/11/2006 13:20:00 14.2 1.3 17.9 10.3 14.5 1.4 17.9 10.3 13.7 1.5 16.8 8.8 129 5 143 165 1.1 0 1.4 0.9 03/11/2006 13:30:00 13.2 1.3 16.4 9.1 13.4 1.3 16.8 9.1 13 1.5 16.4 8.4 132 6 135 165 1.1 0 1.4 0.9 03/11/2006 13:40:00 12.6 1 15.6 9.5 12.8 1.1 16.1 9.9 12.4 1.2 15.6 9.1 131 7 128 165 1.2 0 1.4 1.1 03/11/2006 13:50:00 12.9 1.1 15.6 10.7 13 1.2 16.1 10.3 12.7 1.3 15.6 9.5 134 6 143 165 1.3 0 1.4 1.4 03/11/2006 14:00:00 14.1 1.2 16.8 11.5 14.3 1.2 17.2 11.5 14 1.3 16.8 9.9 132 7 126 165 1.4 0 1.6 1.4 03/11/2006 14:10:00 14.3 1.3 17.2 10.7 14.5 1.3 17.6 10.7 14.2 1.4 17.2 10.3 133 6 127 165 1.4 0 1.6 1.4 03/11/2006 14:20:00 14.1 1.2 16.8 10.3 14.3 1.2 17.2 10.3 14 1.3 17.2 9.5 134 6 128 165 1.4 0 1.6 1.4 03/11/2006 14:30:00 13.8 1.7 17.9 9.9 13.9 1.7 17.9 9.5 13.5 2 17.6 8.4 131 10 143 165 1.3 0 1.6 1.4 03/11/2006 14:40:00 12.6 1.2 15.3 9.1 12.8 1.3 15.6 9.5 12.3 1.4 16.1 8 127 6 116 165 1.2 0 1.4 1.4 03/11/2006 14:50:00 13.7 1.5 17.6 9.9 14 1.6 18.3 9.9 13.4 1.8 17.6 9.5 127 6 121 165 1.2 0 1.4 1.1 03/11/2006 15:00:00 13.8 1.6 17.2 8.8 14 1.6 17.6 8.8 13.6 1.8 17.9 7.6 125 6 127 165 1.1 0 1.4 1.1 03/11/2006 15:10:00 13.4 1.3 16.8 9.9 13.6 1.3 17.2 9.9 13.2 1.3 16.4 9.5 123 6 119 165 1.1 0 1.4 0.9 03/11/2006 15:20:00 12.9 1.4 16.4 8.8 13.1 1.5 16.4 9.1 12.4 1.5 15.6 8 122 7 118 165 1.1 0 1.4 0.9 03/11/2006 15:30:00 13.5 1.3 16.4 9.9 13.7 1.3 16.4 10.3 13.2 1.4 16.4 9.5 124 7 126 165 1 0 1.4 0.9 03/11/2006 15:40:00 13.8 1.2 16.8 9.5 14 1.3 17.2 9.5 13.5 1.3 16.8 9.1 123 5 116 165 0.9 0 1.1 0.9 03/11/2006 15:50:00 12.7 1.4 15.6 9.5 12.8 1.4 16.1 9.1 12.2 1.3 15.3 8.8 119 7 115 165 0.9 0 1.1 0.9 03/11/2006 16:00:00 12.6 1.1 15.3 9.5 12.8 1.2 15.6 9.5 12.3 1.1 14.9 8.4 120 5 118 165 1 0 1.1 0.9 03/11/2006 16:10:00 11.9 1.4 15.3 8 12.1 1.4 15.3 8.4 11.5 1.7 15.3 7.2 120 7 119 165 1 0 1.1 0.9 03/11/2006 16:20:00 11.4 1.5 15.6 8 11.6 1.5 16.1 8.4 11.1 1.5 14.9 8 118 7 113 165 0.9 0 1.1 0.9 03/11/2006 16:30:00 12.4 1.6 16.1 8 12.6 1.6 16.4 8.8 12.1 1.7 15.3 7.6 120 9 110 165 0.9 0 1.4 0.9 03/11/2006 16:40:00 13.2 1.4 16.8 9.5 13.4 1.5 17.6 9.5 12.7 1.5 16.8 8 118 6 116 165 0.9 0 1.4 0.9 03/11/2006 16:50:00 13.8 1.3 17.2 10.3 14 1.3 17.6 11.1 13.3 1.4 16.8 9.9 120 6 121 165 0.9 0 1.1 0.9 03/11/2006 17:00:00 12.5 1.5 16.4 8.8 12.8 1.6 16.8 9.1 12.2 1.4 16.1 8 120 5 119 165 0.8 0 1.1 0.9 03/11/2006 17:10:00 13 1.7 16.8 8 13.2 1.8 17.2 8 12.3 1.8 16.4 8 118 7 111 165 0.7 0 0.9 0.7 03/11/2006 17:20:00 13.2 1.3 16.1 9.5 13.4 1.2 16.4 9.5 12.5 1.3 16.1 9.1 116 6 111 165 0.5 0 0.7 0.4 03/11/2006 17:30:00 12.8 1.7 16.4 8 13.1 1.7 16.8 8.4 12.3 1.8 16.4 7.6 116 7 113 165 0.6 0 0.7 0.7 03/11/2006 17:40:00 13.9 1.2 16.8 10.3 14.2 1.3 17.2 10.7 13.2 1.5 16.1 8.8 108 5 117 165 0.5 0 0.7 0.4 03/11/2006 17:50:00 14.4 1.3 16.8 9.5 14.6 1.3 17.2 9.5 13.7 1.5 16.8 9.5 105 5 101 165 0.4 0 0.7 0.2 03/11/2006 18:00:00 13.8 1.2 16.1 9.9 14 1.2 16.8 10.3 13.2 1.3 17.2 9.9 106 6 108 165 0.3 0.1 0.7 0.2 03/11/2006 18:10:00 13.4 1.5 16.4 9.1 13.6 1.6 16.8 9.1 12.5 1.8 16.1 6.8 109 6 115 165 0.2 0 0.2 -0.1 03/11/2006 18:20:00 12 1.6 16.4 7.6 12.2 1.7 16.8 7.6 11.2 1.6 14.5 6.8 113 8 116 165 -0.1 0 0.2 -0.3 03/11/2006 18:30:00 11.5 1.4 14.5 7.2 11.7 1.4 15.3 7.6 10.7 1.5 14.1 6.8 112 7 110 165 -0.3 0 -0.1 -0.3 03/11/2006 18:40:00 13.3 1.3 16.4 9.9 13.6 1.4 17.2 9.9 12.6 1.6 16.8 8.4 112 7 118 165 -0.3 0 -0.1 -0.3 03/11/2006 18:50:00 13 1.5 15.6 8.8 13.3 1.5 16.1 9.1 12.2 1.6 15.3 8 109 5 111 165 -0.3 0 -0.1 -0.3 03/11/2006 19:00:00 11.7 1.3 15.3 8 11.9 1.4 15.3 8 10.9 1.5 14.1 7.2 109 6 108 165 -0.2 0 -0.1 -0.5 03/11/2006 19:10:00 12 1.2 15.3 8.4 12.2 1.2 15.3 8.4 11.3 1.3 14.5 7.2 111 7 108 165 -0.1 0 0.2 -0.3 03/11/2006 19:20:00 11.9 1.5 15.6 6.5 12.1 1.6 15.6 6.5 11.2 1.6 15.6 7.6 111 7 110 165 0.1 0 0.2 -0.1 03/11/2006 19:30:00 12.7 1.2 15.6 8.8 12.9 1.2 15.6 9.1 11.9 1.3 14.5 8.4 105 5 108 165 0.2 0 0.2 0.2 03/11/2006 19:40:00 12 1.6 15.3 7.6 12.2 1.7 15.6 7.6 11.1 1.7 14.9 6.5 109 7 107 165 0.2 0 0.2 0.2 03/11/2006 19:50:00 11.7 1.3 14.1 8 11.9 1.3 14.5 8.4 11.1 1.3 14.1 7.6 107 5 101 165 0.1 0 0.2 -0.1 03/11/2006 20:00:00 11.8 1.2 14.9 8 12 1.3 14.9 7.2 11.2 1.4 14.1 7.2 108 5 93 165 0.2 0 0.4 0.2 03/11/2006 20:10:00 11.2 1.1 14.5 7.6 11.4 1.1 15.3 8 10.5 1.2 13.7 6.8 105 6 109 165 0.4 0 0.7 0.2 03/11/2006 20:20:00 12.1 1.5 15.6 7.2 12.3 1.5 15.6 7.6 11.4 1.6 15.3 7.2 104 6 105 165 0.5 0 0.7 0.2 03/11/2006 20:30:00 12 1.2 14.9 8 12.2 1.2 15.3 8.4 11.3 1.3 14.9 8.4 105 6 102 165 0.5 0 0.7 0.2 03/11/2006 20:40:00 11.9 1.2 14.5 8.8 12.1 1.2 14.5 8.4 10.9 1.4 14.5 7.2 101 6 94 165 0.5 0 0.7 0.2 03/11/2006 20:50:00 11.5 1.2 14.1 8 11.7 1.3 14.5 8.4 10.7 1.3 13.7 7.2 104 6 106 165 0.5 0 0.7 0.4 03/11/2006 21:00:00 12.4 1.2 15.3 8 12.6 1.2 15.6 8.8 11.7 1.3 14.5 7.6 103 7 83 165 0.5 0 0.7 0.4 03/11/2006 21:10:00 12 1.2 14.5 7.6 12.3 1.2 14.9 7.6 11.3 1.3 14.5 7.2 100 6 86 165 0.5 0 0.7 0.2 03/11/2006 21:20:00 11.4 1.2 14.9 8 11.6 1.2 15.3 8 10.6 1.3 13.7 7.2 102 6 107 165 0.4 0 0.7 0.2 03/11/2006 21:30:00 11.3 1.4 14.5 8 11.5 1.4 14.5 8 10.5 1.5 13.7 6.1 103 8 93 165 0.5 0 0.7 0.2 03/11/2006 21:40:00 11.3 1.2 14.1 7.6 11.5 1.2 14.1 7.2 10.5 1.2 13.3 6.8 109 6 107 165 0.6 0 0.7 0.4 03/11/2006 21:50:00 12.7 1.7 16.1 7.2 12.8 1.7 16.4 7.6 11.9 1.8 16.4 6.8 109 6 105 165 0.7 0 0.9 0.7 03/11/2006 22:00:00 12.6 1.2 15.3 9.1 12.8 1.2 16.1 9.1 12 1.3 14.9 8.8 107 6 106 165 0.7 0 0.9 0.7 03/11/2006 22:10:00 11.4 1.3 14.1 8.4 11.6 1.3 14.9 8.4 10.7 1.4 13.7 6.5 107 7 99 165 0.8 0 0.9 0.7 03/11/2006 22:20:00 12.4 1.5 16.1 7.2 12.6 1.5 16.1 7.2 11.7 1.7 15.3 7.6 106 6 112 165 0.8 0 0.9 0.7 03/11/2006 22:30:00 13.4 1.1 16.4 9.1 13.6 1.1 16.4 8.8 12.6 1.4 16.4 9.1 105 6 100 165 0.8 0 0.9 0.7 03/11/2006 22:40:00 12.7 1.2 16.1 9.1 12.9 1.3 16.4 9.5 11.8 1.5 16.1 7.6 109 6 114 165 0.8 0 0.9 0.7 03/11/2006 22:50:00 14.4 1.1 16.8 10.3 14.6 1.1 17.2 10.7 13.6 1.3 16.4 9.1 108 5 110 165 0.8 0 0.9 0.7 03/11/2006 23:00:00 13.3 1.5 16.8 8.8 13.5 1.5 17.6 9.1 12.6 1.5 16.4 8.4 110 5 114 165 0.8 0 0.9 0.7 03/11/2006 23:10:00 13.1 1.2 16.4 9.9 13.3 1.3 16.8 9.9 12.3 1.6 15.6 8.8 109 5 111 165 0.8 0 0.9 0.7 03/11/2006 23:20:00 12.7 1.6 16.1 7.2 12.9 1.7 16.1 8 11.8 1.7 15.3 7.6 110 6 109 165 0.8 0 0.9 0.9 03/11/2006 23:30:00 13 1.4 15.6 8 13.3 1.5 16.1 8.4 12.3 1.5 15.6 7.6 108 5 106 165 0.8 0 0.9 0.9 03/11/2006 23:40:00 12.7 1.2 16.1 8.8 12.9 1.2 16.1 9.1 11.8 1.5 15.3 7.6 107 7 112 165 0.8 0 1.1 0.9 03/11/2006 23:50:00 12.1 1.4 15.6 8 12.2 1.5 15.6 7.6 11.3 1.5 14.9 7.6 107 6 106 165 0.9 0 1.1 0.9 03/12/2006 00:00:00 12 1.6 15.3 8 12.3 1.6 15.6 8 11.2 1.7 14.9 7.2 104 7 112 165 0.9 0 1.1 0.9 03/12/2006 00:10:00 12.7 1.5 15.6 8 13 1.5 15.6 8 12 1.6 16.1 8 107 5 98 165 0.9 0 1.1 0.9 03/12/2006 00:20:00 11.1 1.3 14.1 6.8 11.2 1.4 14.1 7.2 10.3 1.3 13.3 7.2 103 7 106 165 0.9 0 1.4 0.9 03/12/2006 00:30:00 11.7 1.2 15.3 6.8 11.9 1.2 15.6 7.6 11 1.2 14.1 7.6 106 6 97 165 0.9 0 1.1 0.9 03/12/2006 00:40:00 10.9 1 13.3 8 11.1 1 13.7 8 10.3 1.2 13 6.8 105 6 92 165 1 0 1.1 0.9 03/12/2006 00:50:00 11.7 1.2 14.9 8 11.8 1.3 14.9 8.4 10.9 1.3 14.1 7.6 103 5 123 165 0.9 0 1.1 0.9 03/12/2006 01:00:00 11.5 1.5 14.5 7.6 11.7 1.5 14.9 7.6 10.6 1.5 14.5 6.5 106 7 94 165 1 0 1.1 0.9 03/12/2006 01:10:00 10.8 1.2 13.7 7.6 11 1.2 13.7 7.2 10.3 1.1 13.7 7.6 104 7 99 165 1 0 1.1 0.9 03/12/2006 01:20:00 11.2 1.1 13.3 7.6 11.3 1.1 13.7 8 10.5 1.2 13 7.2 103 6 104 165 0.8 0 1.1 0.9 03/12/2006 01:30:00 10.7 1.2 13.3 7.6 10.8 1.2 13.7 7.6 9.9 1.3 13 6.8 102 6 107 165 0.8 0 1.1 0.9 03/12/2006 01:40:00 11.3 1.4 14.1 6.8 11.5 1.5 14.1 6.8 10.5 1.5 14.5 6.8 103 7 107 165 0.9 0 1.1 0.9 03/12/2006 01:50:00 11.7 1.1 14.1 7.6 12 1.2 14.5 8.4 11 1.3 14.5 6.5 100 6 95 165 0.9 0 1.1 0.9 03/12/2006 02:00:00 10.5 1.2 13.7 6.8 10.7 1.3 13.3 6.8 9.8 1.2 12.6 6.8 104 7 101 165 1 0 1.1 0.9 03/12/2006 02:10:00 11.6 1.2 14.9 7.6 11.8 1.2 14.5 8.4 10.8 1.2 13.7 7.6 100 6 102 165 1.1 0 1.1 0.9 03/12/2006 02:20:00 11.9 1.3 14.9 8.4 12.1 1.3 14.9 8.8 11.3 1.3 14.1 7.2 101 6 102 165 1.1 0 1.4 0.9 03/12/2006 02:30:00 12.3 1.2 14.9 8.4 12.5 1.2 14.9 8.8 11.4 1.3 14.1 7.6 99 6 101 165 1.1 0 1.4 0.9 03/12/2006 02:40:00 11.8 1.2 14.5 8.8 12 1.2 14.5 9.1 11.1 1.3 14.1 7.2 96 6 98 165 1.2 0 1.4 0.9 03/12/2006 02:50:00 11.5 1.3 14.1 8 11.7 1.3 14.5 8 10.9 1.3 13.7 7.6 92 7 87 165 1.2 0 1.4 1.1 03/12/2006 03:00:00 11.6 1 14.1 8.8 11.8 1.1 14.1 8.4 10.9 1.2 13.7 6.8 96 6 97 165 1.2 0 1.4 1.1 03/12/2006 03:10:00 11.7 1.3 15.3 8.4 11.9 1.3 15.3 8.8 11 1.5 14.5 7.6 96 6 101 165 1.2 0 1.4 1.1 03/12/2006 03:20:00 11.5 1.2 14.5 8 11.7 1.2 15.3 8 10.8 1.3 14.1 8 93 6 89 165 1.2 0 1.4 1.1 03/12/2006 03:30:00 11.9 1.3 14.9 7.6 12.1 1.3 15.3 7.6 11 1.3 14.1 7.6 95 6 94 165 1.3 0 1.4 1.4 03/12/2006 03:40:00 11.3 1.2 14.5 8.4 11.5 1.3 14.9 8.4 10.8 1.3 14.5 6.8 93 7 77 165 1.3 0 1.4 1.4 03/12/2006 03:50:00 11.3 1.2 13.7 8 11.4 1.2 14.1 8.4 10.6 1.2 13.7 7.2 95 7 99 165 1.4 0 1.4 1.4 03/12/2006 04:00:00 11.2 1.4 14.5 7.2 11.3 1.4 14.1 7.6 10.5 1.3 14.5 7.2 94 7 96 165 1.3 0 1.4 1.4 03/12/2006 04:10:00 11.9 1.1 14.5 8.4 12.2 1.1 14.5 8.8 11.4 1.2 13.7 8.4 94 7 95 165 1.4 0 1.4 1.4 03/12/2006 04:20:00 11.5 1.5 14.5 7.6 11.7 1.5 15.3 7.6 10.8 1.5 15.3 6.8 94 7 91 165 1.4 0 1.4 1.4 03/12/2006 04:30:00 11.7 1.3 14.9 8 11.9 1.3 15.3 8.4 11 1.2 15.3 8.4 95 6 102 165 1.4 0 1.4 1.4 03/12/2006 04:40:00 11.3 1.2 14.5 8.4 11.5 1.3 14.9 8.4 10.7 1.3 14.5 7.2 94 7 88 165 1.4 0 1.6 1.4 03/12/2006 04:50:00 11.2 1.3 14.9 7.2 11.4 1.3 15.6 7.6 10.6 1.3 14.5 7.6 92 7 74 165 1.4 0 1.6 1.4 03/12/2006 05:00:00 11.7 1.2 14.5 8.4 11.9 1.2 14.5 8.8 11.1 1.3 13.7 7.2 89 6 93 165 1.4 0 1.6 1.4 03/12/2006 05:10:00 11.3 1.5 14.9 7.6 11.5 1.5 15.3 7.2 10.8 1.3 14.5 7.2 89 8 84 165 1.4 0 1.4 1.4 03/12/2006 05:20:00 12.2 1.2 14.9 8.8 12.4 1.2 14.9 8.8 11.5 1.3 14.5 8 88 6 94 165 1.4 0 1.6 1.4 03/12/2006 05:30:00 11.2 1.5 15.3 7.6 11.4 1.5 15.3 8 10.7 1.5 14.5 6.5 89 7 85 165 1.4 0 1.6 1.4 03/12/2006 05:40:00 11 1.1 13.3 8 11.2 1.2 14.1 8.4 10.5 1.1 13 8 86 6 89 165 1.4 0 1.6 1.4 03/12/2006 05:50:00 11.1 1.4 14.5 7.2 11.4 1.4 15.3 7.6 10.6 1.2 14.1 7.6 91 8 102 165 1.4 0 1.6 1.4 03/12/2006 06:00:00 11 1.2 13.7 8 11.2 1.2 14.1 8.4 10.5 1.2 14.1 8 90 7 91 165 1.4 0 1.6 1.4 03/12/2006 06:10:00 11.5 1.5 14.9 7.6 11.7 1.6 15.3 7.6 11 1.6 15.3 7.6 89 7 84 165 1.4 0 1.6 1.4 03/12/2006 06:20:00 11.2 1.3 14.9 7.2 11.4 1.4 14.5 7.6 10.7 1.5 13.7 7.2 91 8 89 165 1.4 0 1.6 1.4 03/12/2006 06:30:00 11.4 1.3 14.5 7.6 11.7 1.4 14.9 7.6 10.9 1.3 14.5 7.6 89 7 87 165 1.4 0 1.6 1.4 03/12/2006 06:40:00 11.2 1.3 14.5 7.2 11.4 1.4 14.5 8 10.7 1.3 13.7 7.6 91 7 77 165 1.4 0 1.6 1.4 03/12/2006 06:50:00 11.1 1.2 14.1 8 11.3 1.3 14.1 8 10.6 1.3 13.7 7.2 85 6 84 165 1.4 0 1.6 1.4 03/12/2006 07:00:00 11.4 1.5 14.5 6.8 11.6 1.5 14.9 7.2 11.1 1.5 14.5 7.2 87 8 85 165 1.4 0 1.6 1.4 03/12/2006 07:10:00 10.9 1.4 14.1 6.8 11.1 1.5 14.5 6.8 10.6 1.4 13.7 7.2 88 8 83 165 1.4 0 1.6 1.4 03/12/2006 07:20:00 10.6 1.3 14.5 7.2 10.9 1.4 14.5 7.2 10.3 1.3 14.1 6.8 84 7 88 165 1.4 0 1.6 1.4 03/12/2006 07:30:00 9.9 1.5 14.5 6.8 10.1 1.7 14.9 6.5 9.7 1.7 14.9 5.7 84 8 90 165 1.4 0 1.6 1.4 03/12/2006 07:40:00 10.5 1.3 14.1 7.2 10.7 1.3 14.1 7.2 10.2 1.3 13 6.5 83 7 87 165 1.3 0 1.4 1.4 03/12/2006 07:50:00 10.1 1.3 13.3 7.2 10.3 1.3 13.7 7.2 9.8 1.3 13 6.5 83 9 83 165 1.2 0 1.4 1.1 03/12/2006 08:00:00 10 1.3 13.7 6.8 10.2 1.3 14.1 7.2 9.5 1.3 13 5.3 86 7 87 165 1.4 0 1.6 1.4 03/12/2006 08:10:00 10.8 1.4 14.1 7.6 11.1 1.5 14.5 7.6 10.4 1.4 13.3 6.5 84 6 81 165 1.4 0 1.6 1.4 03/12/2006 08:20:00 10.4 1.1 13 8 10.6 1.1 13.3 7.6 10.1 1.2 14.1 7.6 79 9 77 165 1.3 0 1.4 1.4 03/12/2006 08:30:00 9.7 1.4 13.3 6.1 9.9 1.5 13.3 5.7 9.4 1.3 12.6 6.1 77 7 70 165 1.2 0 1.4 1.1 03/12/2006 08:40:00 9.4 1.2 13.3 5.7 9.5 1.3 13.3 6.1 9.1 1 12.6 5.7 75 9 88 165 1.1 0 1.4 0.9 03/12/2006 08:50:00 9 1 13 6.1 9.2 1.1 13 6.5 8.8 0.9 12.2 6.5 75 8 91 165 0.9 0 1.1 0.9 03/12/2006 09:00:00 9.4 1.3 13.3 6.1 9.6 1.5 14.1 6.1 9.2 1.3 13 6.5 74 8 73 165 0.9 0 1.1 0.9 03/12/2006 09:10:00 9.3 1.2 13.7 6.8 9.4 1.2 13.7 6.1 8.9 1.1 12.6 6.1 74 8 82 165 0.9 0 1.1 0.9 03/12/2006 09:20:00 9.2 1.2 13 6.5 9.4 1.2 13.3 6.5 8.9 1.1 12.2 5.7 75 7 76 165 0.9 0 1.1 0.9 03/12/2006 09:30:00 9.6 1.2 13 6.1 9.8 1.2 13.3 6.5 9.2 1.2 12.2 6.5 80 7 80 165 0.9 0 1.1 0.9 03/12/2006 09:40:00 9 1 11.5 6.1 9.1 1 12.2 6.1 8.7 1 11.1 6.1 76 8 75 165 1.1 0 1.4 0.9 03/12/2006 09:50:00 9.8 1.4 13.3 6.1 10 1.5 13.7 6.1 9.5 1.4 13.3 6.1 80 7 85 165 1.1 0 1.4 0.9 03/12/2006 10:00:00 9.6 1.2 12.6 6.1 9.8 1.2 13 6.1 9.3 1.3 12.6 5.7 81 7 91 165 1.2 0 1.4 1.1 03/12/2006 10:10:00 8.7 1 11.5 5.7 8.8 1 11.8 5.3 8.3 0.9 10.7 6.1 83 8 84 165 1.2 0 1.4 1.1 03/12/2006 10:20:00 9 1.3 12.6 5.3 9.1 1.3 12.6 5.7 8.7 1.2 12.2 5.3 81 7 85 165 1.2 0 1.4 1.1 03/12/2006 10:30:00 7.9 1.1 11.5 4.6 7.9 1.2 11.8 4.6 7.6 1.1 10.3 4.9 72 9 75 165 1.2 0 1.4 1.1 03/12/2006 10:40:00 9.1 1.6 12.6 5.3 9.2 1.7 13 4.9 8.7 1.6 12.2 4.6 72 8 80 165 1.1 0 1.4 0.9 03/12/2006 10:50:00 9.2 1.7 13.3 5.3 9.3 1.7 13.7 4.9 8.9 1.7 13.7 4.9 72 10 75 165 1 0 1.1 0.9 03/12/2006 11:00:00 8.1 1.5 12.6 4.9 8.1 1.5 13 4.9 7.7 1.2 12.2 5.3 73 10 84 165 1 0 1.1 0.9 03/12/2006 11:10:00 10 1.2 12.6 6.8 10.2 1.3 13 6.5 9.7 1.3 12.6 6.5 75 7 81 165 0.8 0.1 1.1 0.7 03/12/2006 11:20:00 8.6 1.1 11.1 6.1 8.8 1.1 11.5 6.1 8.2 1 10.3 5.3 71 8 61 165 0.7 0 0.9 0.7 03/12/2006 11:30:00 8.2 1.5 12.2 5.3 8.3 1.5 12.2 5.3 8 1.3 11.5 5.3 71 9 81 165 0.6 0 0.9 0.4 03/12/2006 11:40:00 9.1 1.1 12.2 6.8 9.3 1.1 12.2 6.8 8.7 1.1 11.8 6.8 72 7 82 165 0.5 0 0.7 0.2 03/12/2006 11:50:00 9.6 1.4 13.3 6.1 9.7 1.5 13.7 6.1 9.1 1.3 13 6.1 70 8 70 165 0.6 0 0.9 0.4 03/12/2006 12:00:00 9.6 1.3 13.3 6.1 9.8 1.4 13.3 6.5 9.4 1.3 13 6.1 70 10 65 165 0.7 0 0.9 0.7 03/12/2006 12:10:00 9.8 1.1 13 6.8 10 1.2 13.3 6.8 9.4 1.2 13 5.3 68 8 68 165 0.7 0 0.9 0.7 03/12/2006 12:20:00 9 1.2 12.2 5.3 9.1 1.2 12.2 5.7 8.7 1 11.1 5.7 66 9 67 165 0.6 0 0.9 0.7 03/12/2006 12:30:00 9.2 1.6 13.3 4.9 9.2 1.6 13.3 4.9 8.9 1.5 12.2 4.9 62 9 68 165 0.5 0 0.9 0.4 03/12/2006 12:40:00 9 1.3 12.2 6.1 9.2 1.4 12.6 6.1 8.6 1.3 12.2 5.7 59 9 57 165 0.5 0 0.9 0.2 03/12/2006 12:50:00 8.3 1.4 12.2 4.9 8.4 1.5 12.2 5.3 7.9 1.5 11.5 4.9 58 11 49 165 0.7 0 0.9 0.7 03/12/2006 13:00:00 7.7 1.3 11.5 4.9 7.6 1.4 11.8 4.9 7.4 1.2 11.5 4.6 55 11 72 165 0.8 0 0.9 0.7 03/12/2006 13:10:00 8.4 1.5 12.6 5.3 8.4 1.6 13 5.3 8.2 1.5 12.6 4.9 60 11 58 165 0.8 0 0.9 0.9 03/12/2006 13:20:00 7.7 1.4 11.5 4.2 7.7 1.5 11.8 4.2 7.5 1.5 11.5 3 58 12 65 165 0.8 0 1.1 0.9 03/12/2006 13:30:00 8.2 1.5 11.8 4.6 8.2 1.5 11.8 4.6 7.9 1.4 11.5 4.2 56 11 55 165 0.8 0 0.9 0.7 03/12/2006 13:40:00 7.9 1.5 11.8 4.6 7.9 1.6 12.2 4.2 7.6 1.5 11.5 4.6 51 11 58 165 0.8 0 0.9 0.9 03/12/2006 13:50:00 6.9 1.2 11.8 4.2 6.8 1.3 11.8 3.8 6.6 1.2 12.2 4.6 43 12 68 165 0.9 0 1.1 0.9 03/12/2006 14:00:00 7.7 1.7 11.8 4.6 7.6 1.8 12.2 4.2 7.3 1.7 11.5 3.8 49 11 47 165 1 0 1.1 0.9 03/12/2006 14:10:00 7.6 1.3 10.3 4.9 7.6 1.3 10.7 4.6 7.3 1.2 10.3 4.9 51 11 46 165 0.9 0 1.1 0.9 03/12/2006 14:20:00 8.4 1.5 13.3 5.3 8.4 1.5 13 5.3 8 1.3 11.5 3.8 53 11 68 165 0.9 0 1.1 0.9 03/12/2006 14:30:00 7.1 1 11.1 4.6 6.9 1.1 11.1 4.2 6.6 1 10.3 4.2 47 12 65 165 0.9 0 1.1 0.9 03/12/2006 14:40:00 7.4 1.4 11.1 4.2 7.3 1.5 11.1 3.8 7.1 1.4 10.3 4.2 46 11 53 165 1 0 1.1 0.9 03/12/2006 14:50:00 7 1.1 9.9 4.6 6.9 1.1 9.9 4.2 6.7 1 9.5 4.2 45 13 51 165 1.1 0 1.4 0.9 03/12/2006 15:00:00 7.2 1 9.9 5.3 7.1 1 9.9 4.9 7.1 1 9.5 4.2 43 11 60 165 1.1 0 1.4 0.9 03/12/2006 15:10:00 7.2 1.2 11.1 4.9 7.1 1.3 11.5 4.6 6.9 1.2 11.1 3.8 43 11 39 165 1.2 0 1.4 1.1 03/12/2006 15:20:00 7.8 1.3 10.7 4.6 7.7 1.4 11.1 4.6 7.6 1.3 11.5 4.6 45 9 57 165 1.2 0 1.4 1.1 03/12/2006 15:30:00 7.3 1 10.7 4.6 7.2 1.1 10.7 4.6 7 1 9.9 4.6 41 9 37 165 1.2 0 1.4 1.1 03/12/2006 15:40:00 6.8 1 9.9 4.2 6.6 1 9.9 3.8 6.6 1 9.1 4.2 40 9 46 165 1.3 0 1.4 1.1 03/12/2006 15:50:00 7.1 1.1 9.5 4.6 6.9 1.2 9.9 4.2 6.9 1.1 10.3 4.2 43 10 51 165 1.3 0 1.4 1.4 03/12/2006 16:00:00 7.7 1.2 10.7 4.6 7.6 1.2 10.7 4.6 7.2 1.1 9.9 4.9 47 10 37 165 1.4 0 1.6 1.4 03/12/2006 16:10:00 7.6 1.2 11.5 4.6 7.5 1.2 11.5 4.6 7.2 1 9.5 4.6 43 9 35 165 1.4 0 1.6 1.4 03/12/2006 16:20:00 7.7 1.1 10.7 5.3 7.6 1.1 10.7 4.9 7.2 1 9.9 4.6 40 9 37 165 1.4 0 1.6 1.4 03/12/2006 16:30:00 8 1.3 11.8 4.9 8 1.4 11.8 4.6 7.6 1.3 11.8 4.2 47 9 58 165 1.4 0 1.6 1.4 03/12/2006 16:40:00 7.3 1.5 11.1 4.2 7.2 1.5 11.1 3.8 6.9 1.3 10.7 3.8 47 10 56 165 1.5 0 1.6 1.4 03/12/2006 16:50:00 7.8 1.3 11.5 5.3 7.7 1.4 11.5 5.3 7.4 1.3 11.8 4.6 51 10 59 165 1.5 0 1.6 1.4 03/12/2006 17:00:00 7.3 1.1 10.3 4.6 7.2 1.2 10.7 3.8 6.7 1 8.8 4.2 54 10 56 165 1.5 0 1.6 1.4 03/12/2006 17:10:00 7.2 1.5 10.7 3.4 7.1 1.6 10.7 3 6.8 1.4 10.7 3.8 52 10 70 165 1.5 0 1.6 1.4 03/12/2006 17:20:00 7.5 1.3 11.1 4.2 7.4 1.3 11.1 3.8 6.9 1.1 10.3 4.6 55 10 58 165 1.6 0 1.6 1.4 03/12/2006 17:30:00 7.6 1.7 11.8 3.8 7.6 1.7 12.6 3.8 7.1 1.5 11.1 3.4 55 8 56 165 1.6 0 1.8 1.6 03/12/2006 17:40:00 8.6 1.5 13 4.2 8.6 1.5 12.6 3.8 8.1 1.4 11.5 4.9 58 9 72 165 1.7 0 1.8 1.6 03/12/2006 17:50:00 8.1 1.4 11.8 5.3 8 1.5 11.8 5.3 7.7 1.4 11.5 4.9 57 9 53 165 1.7 0 1.8 1.6 03/12/2006 18:00:00 9.4 1.5 13.3 6.5 9.3 1.5 13 5.7 8.6 1.3 12.2 5.7 59 9 65 165 1.6 0 1.8 1.4 03/12/2006 18:10:00 8.3 1.5 11.5 3.8 8.2 1.5 11.1 3.4 7.8 1.4 11.1 3.4 58 9 52 165 1.7 0 1.8 1.4 03/12/2006 18:20:00 7.3 1.3 11.8 4.2 7.1 1.3 11.8 3.8 6.6 1.2 9.9 3.8 57 10 62 165 1.6 0 1.8 1.4 03/12/2006 18:30:00 7.7 1.4 11.1 4.6 7.6 1.5 10.7 4.6 7.1 1.3 10.7 4.2 60 9 64 165 1.7 0 1.8 1.6 03/12/2006 18:40:00 8.8 1.4 13 5.3 8.7 1.4 13 4.6 8.2 1.2 11.8 5.3 62 8 70 165 1.7 0 1.8 1.6 03/12/2006 18:50:00 7.3 1.3 11.1 4.6 7.2 1.4 11.5 4.2 6.8 1.2 10.7 3.8 58 10 52 165 1.7 0 1.8 1.6 03/12/2006 19:00:00 7.5 1.2 11.1 4.6 7.4 1.2 11.1 4.2 7 1.1 10.7 4.2 58 10 64 165 1.7 0 1.8 1.6 03/12/2006 19:10:00 8 1.5 12.2 4.6 7.9 1.6 11.8 4.2 7.4 1.3 11.5 4.6 59 9 58 165 1.7 0 1.8 1.6 03/12/2006 19:20:00 8.1 1.6 12.6 4.9 8 1.6 12.6 4.6 7.6 1.3 11.1 4.6 63 9 67 165 1.7 0 1.8 1.6 03/12/2006 19:30:00 7.4 1.7 11.1 3.8 7.4 1.8 11.5 3.8 7 1.6 10.3 3.4 61 10 57 165 1.7 0 1.8 1.6 03/12/2006 19:40:00 7.8 1.4 10.7 4.9 7.7 1.4 10.7 4.2 7.3 1.2 10.3 4.9 59 9 73 165 1.7 0 1.8 1.6 03/12/2006 19:50:00 8.1 1.3 11.1 4.9 8 1.3 11.1 5.3 7.5 1.2 10.3 4.9 63 8 66 165 1.8 0 1.8 1.6 03/12/2006 20:00:00 7.5 1.5 11.1 4.9 7.4 1.5 10.7 4.6 7 1.3 10.7 4.2 61 9 70 165 1.8 0 1.8 1.6 03/12/2006 20:10:00 7.6 1.2 10.3 4.9 7.4 1.2 10.3 4.6 7.1 1 9.5 4.6 63 9 80 165 1.8 0 1.8 1.6 03/12/2006 20:20:00 6.3 1 9.1 4.2 6.1 1 9.1 3.4 5.9 0.8 8 3.8 61 10 52 165 1.8 0 1.8 1.6 03/12/2006 20:30:00 7.5 1.2 11.1 5.3 7.3 1.3 11.5 4.9 6.9 1.1 9.9 4.6 57 9 71 165 1.8 0 1.8 1.6 03/12/2006 20:40:00 7.3 1.1 10.7 4.6 7.1 1.2 10.3 3.8 6.8 1.2 10.3 4.6 59 9 67 165 1.8 0 1.8 1.6 03/12/2006 20:50:00 7.4 1.3 11.8 4.9 7.2 1.4 11.5 4.2 6.7 1.3 10.7 4.2 60 9 61 165 1.8 0 1.8 1.6 03/12/2006 21:00:00 7.9 1.5 11.1 4.9 7.7 1.6 11.1 4.6 7.3 1.5 10.7 4.6 61 8 65 165 1.8 0 1.8 1.6 03/12/2006 21:10:00 7.3 1.2 10.3 3.8 7.1 1.3 10.7 3 6.8 1.2 9.9 4.2 62 8 62 165 1.8 0 1.8 1.6 03/12/2006 21:20:00 6.7 1.1 9.9 4.2 6.5 1.1 9.5 4.2 6.2 1 9.1 4.2 58 9 59 165 1.8 0 1.8 1.6 03/12/2006 21:30:00 6.6 1.6 10.7 3 6.4 1.7 10.7 2.6 6.1 1.3 9.1 3 60 9 68 165 1.8 0 1.8 1.6 03/12/2006 21:40:00 5.9 1.5 10.3 3 5.6 1.6 10.3 2.3 5.2 1.4 9.1 3 56 11 61 165 1.8 0 1.8 1.6 03/12/2006 21:50:00 6.1 1.3 9.5 3 5.9 1.5 9.1 2.6 5.9 1.2 9.1 3 51 9 61 165 1.8 0 1.8 1.6 03/12/2006 22:00:00 5.7 1.2 9.1 3 5.4 1.2 9.1 3 5.2 1.2 8.4 3 52 10 66 165 1.8 0 1.8 1.6 03/12/2006 22:10:00 6.3 0.9 8.8 4.2 6.1 1 8.4 4.2 5.9 1 8.8 3.8 51 10 52 165 1.8 0 1.8 1.6 03/12/2006 22:20:00 5.7 1 8.4 3.4 5.5 1 8.4 3 5.3 0.9 8 3.4 51 11 52 165 1.8 0 1.8 1.6 03/12/2006 22:30:00 5.8 1 8.4 3 5.6 1.1 8.4 3 5.4 1 7.6 3 62 9 65 165 1.8 0 1.8 1.6 03/12/2006 22:40:00 5.9 1.2 9.9 3 5.6 1.3 8.8 2.6 5.5 1.1 8.4 3 54 10 60 165 1.8 0 1.8 1.6 03/12/2006 22:50:00 7.8 1.2 10.3 4.9 7.5 1.2 10.3 4.2 7.1 1.1 9.1 4.6 61 8 60 165 1.8 0 1.8 1.6 03/12/2006 23:00:00 7.1 1.2 9.9 3.8 6.7 1.3 9.9 3 6.2 1.2 9.1 3.8 66 10 72 165 1.8 0 1.8 1.6 03/12/2006 23:10:00 6.1 1.2 9.1 3.4 5.7 1.3 8.8 3 5.7 1.1 8.8 3 69 9 78 165 1.8 0 1.8 1.6 03/12/2006 23:20:00 6.5 1.1 9.1 4.2 6.2 1.2 8.8 3.8 6.1 1 8.8 3.8 64 11 87 165 1.8 0 1.8 1.6 03/12/2006 23:30:00 6.7 0.9 9.1 4.2 6.4 1 8.8 3.4 6.2 0.8 8.4 4.2 70 7 73 165 1.8 0 1.8 1.6 03/12/2006 23:40:00 5 0.8 7.6 3.4 4.7 0.8 7.2 3 4.6 0.7 6.8 3 55 8 54 165 1.8 0 1.8 1.6 03/12/2006 23:50:00 6.7 1.1 9.5 4.2 6.4 1.2 9.5 3.8 6.1 1 9.1 3.8 59 8 58 165 1.8 0 1.8 1.6 03/13/2006 00:00:00 6.4 0.9 8.8 4.6 6.1 1 8.8 3.8 5.8 0.8 8 4.2 61 6 61 165 1.7 0 1.8 1.6 03/13/2006 00:10:00 6.2 1.1 8.8 3.8 6 1.1 8.8 3.4 5.7 1.1 8.8 3.4 61 5 62 165 1.7 0 1.8 1.6 03/13/2006 00:20:00 4.9 1 7.6 3.4 4.6 1.1 7.6 2.6 4.5 1 7.2 2.6 61 0 62 165 1.7 0 1.8 1.6 03/13/2006 00:30:00 5.6 0.9 8.4 3.8 5.3 1 8 3 5.1 0.9 7.2 3 59 4 58 165 1.8 0 1.8 1.6 03/13/2006 00:40:00 5.3 1 8.4 2.3 5 1.1 8 1.9 4.8 1 6.8 2.6 57 8 51 165 1.8 0 1.8 1.6 03/13/2006 00:50:00 4.9 1 7.6 2.3 4.6 1.1 7.2 1.9 4.5 0.9 6.8 2.6 54 9 62 165 1.7 0 1.8 1.6 03/13/2006 01:00:00 4.5 0.7 6.5 2.6 4 0.7 6.1 2.3 4.2 0.6 5.7 2.6 51 10 69 165 1.7 0 1.8 1.6 03/13/2006 01:10:00 5.8 1.2 8.4 2.6 5.5 1.4 8 2.3 5.3 1.2 7.6 2.6 64 10 60 165 1.7 0 1.8 1.6 03/13/2006 01:20:00 5.3 0.9 7.6 3.4 4.9 1 7.6 3 4.8 0.8 6.8 3.4 70 0 70 165 1.7 0 1.8 1.6 03/13/2006 01:30:00 4.9 0.7 6.8 3.4 4.4 0.7 6.5 2.6 4.6 0.7 6.8 2.3 67 10 44 165 1.7 0 1.8 1.6 03/13/2006 01:40:00 4.7 0.7 6.1 2.6 4.3 0.7 6.1 2.3 4.2 0.7 6.1 2.3 44 9 46 165 1.7 0 1.8 1.6 03/13/2006 01:50:00 5.4 0.7 6.8 3 5.1 0.7 6.5 2.6 4.8 0.7 6.5 2.6 44 7 47 165 1.7 0 1.8 1.6 03/13/2006 02:00:00 5.2 0.6 6.5 3.8 4.9 0.6 6.5 3 4.7 0.6 6.1 2.6 46 7 56 165 1.7 0 1.8 1.6 03/13/2006 02:10:00 5.1 0.7 6.8 3 4.8 0.8 6.8 3 4.6 0.6 6.1 3 49 7 55 165 1.7 0 1.8 1.6 03/13/2006 02:20:00 5.4 0.5 6.5 3.8 5.2 0.6 6.5 3.4 4.8 0.6 6.1 3.4 51 6 57 165 1.7 0 1.8 1.6 03/13/2006 02:30:00 6 0.6 7.2 3.8 5.7 0.6 7.2 3 5.4 0.7 6.8 3.8 40 5 44 165 1.7 0 1.8 1.6 03/13/2006 02:40:00 6 0.5 7.2 4.6 5.7 0.5 6.8 4.2 5.7 0.5 6.8 4.2 38 5 36 165 1.7 0 1.8 1.6 03/13/2006 02:50:00 5.6 0.4 6.5 4.2 5.3 0.4 6.1 3.8 5.2 0.5 6.5 3.8 38 3 36 165 1.7 0 1.8 1.6 03/13/2006 03:00:00 4.8 0.5 6.1 3 4.4 0.6 5.7 2.3 4.5 0.6 5.7 2.6 37 5 44 165 1.7 0 1.8 1.4 03/13/2006 03:10:00 4.6 0.4 5.7 3.4 4.1 0.5 4.9 2.6 4.3 0.5 5.3 3 30 5 37 165 1.7 0 1.8 1.6 03/13/2006 03:20:00 4.1 0.5 4.9 2.6 3.3 0.5 4.6 1.5 3.8 0.4 4.9 2.6 23 6 29 165 1.7 0 1.8 1.6 03/13/2006 03:30:00 4.8 0.5 6.1 3 4 0.6 5.3 1.9 4.5 0.6 5.7 3 19 4 19 165 1.7 0 1.8 1.6 03/13/2006 03:40:00 5.2 0.6 6.8 3.4 4.4 0.7 6.1 2.6 5 0.7 6.5 3.4 23 6 22 165 1.7 0 1.8 1.6 03/13/2006 03:50:00 5.5 0.5 6.8 3.8 4.9 0.6 6.5 3 5.1 0.5 6.5 3.8 25 5 34 165 1.7 0 1.8 1.6 03/13/2006 04:00:00 5.7 0.4 6.8 4.2 5 0.6 6.5 3 5.5 0.5 6.5 4.2 21 5 26 165 1.7 0 1.8 1.6 03/13/2006 04:10:00 5.7 0.5 6.8 4.2 4.7 0.7 6.1 3.4 5.4 0.5 6.5 4.2 17 3 21 165 1.7 0 1.8 1.6 03/13/2006 04:20:00 5.6 0.6 7.2 4.2 4.7 0.7 6.1 3 5.4 0.5 6.8 4.2 17 4 11 165 1.7 0 1.8 1.6 03/13/2006 04:30:00 5.2 0.5 6.5 3.8 3.7 0.8 5.7 1.9 5 0.5 6.5 3.8 12 6 16 165 1.7 0 1.8 1.6 03/13/2006 04:40:00 6.1 0.4 6.8 4.9 5.1 0.6 6.5 3.4 5.8 0.4 6.8 4.6 16 3 18 165 1.7 0 1.8 1.6 03/13/2006 04:50:00 6.4 0.5 7.2 4.9 5.4 0.8 6.8 3 6.1 0.6 7.2 4.6 20 4 14 165 1.7 0 1.8 1.6 03/13/2006 05:00:00 6.7 0.3 7.6 5.3 5.4 0.6 6.8 3.8 6.5 0.4 7.6 5.3 14 3 13 165 1.7 0 1.8 1.6 03/13/2006 05:10:00 6.4 0.5 7.6 5.3 5.3 0.7 6.8 3.8 6.2 0.4 7.2 5.3 15 1 18 165 1.6 0 1.8 1.6 03/13/2006 05:20:00 6 0.3 6.8 4.9 5.2 0.4 6.1 4.2 5.7 0.4 6.5 4.6 15 0 15 165 1.6 0 1.8 1.4 03/13/2006 05:30:00 5.5 0.3 6.1 4.6 4.7 0.3 5.7 3.8 5.3 0.3 6.1 4.2 15 0 15 165 1.5 0 1.6 1.4 03/13/2006 05:40:00 5.9 0.5 7.6 4.6 3.7 1 6.8 1.9 5.7 0.5 7.2 4.6 15 0 15 165 1.5 0 1.6 1.4 03/13/2006 05:50:00 6.4 0.6 8.4 4.9 3.5 1.1 6.5 1.5 6.1 0.5 7.6 4.9 15 0 15 165 1.6 0 1.6 1.4 03/13/2006 06:00:00 6.3 0.6 7.6 4.9 3.5 1.1 6.8 1.5 6.3 0.6 8 5.3 15 0 15 165 1.6 0 1.6 1.4 03/13/2006 06:10:00 6 0.5 7.2 4.6 3 0.8 6.1 1.5 6 0.5 7.2 4.9 15 0 15 165 1.6 0 1.8 1.4 03/13/2006 06:20:00 6.1 0.5 7.6 4.9 3.1 1.1 7.2 1.5 5.9 0.5 7.2 4.9 15 0 15 165 1.6 0 1.8 1.4 03/13/2006 06:30:00 6.7 0.8 8.8 4.6 3.8 1.3 7.6 1.5 6.4 0.8 8 4.2 15 0 15 165 1.6 0 1.8 1.6 03/13/2006 06:40:00 6.4 0.5 7.6 5.3 3.1 0.8 5.7 1.5 6.1 0.4 7.2 4.9 15 0 15 165 1.6 0 1.8 1.6 03/13/2006 06:50:00 5.3 0.7 7.2 3.8 4.2 1.2 6.5 1.5 5 0.6 6.5 3.4 15 0 15 165 1.6 0 1.8 1.4 03/13/2006 07:00:00 4.9 0.6 6.5 3.4 2.5 0.8 5.3 0.7 4.8 0.6 6.1 3.4 15 0 15 165 1.6 0 1.6 1.4 03/13/2006 07:10:00 5.7 0.7 7.6 3.8 2.9 0.9 6.1 1.1 5.6 0.8 7.2 3.8 15 0 15 165 1.6 0 1.8 1.6 03/13/2006 07:20:00 6.1 0.4 7.2 4.9 3.3 1 6.1 1.9 5.9 0.5 7.2 4.6 15 0 15 165 1.5 0 1.6 1.4 03/13/2006 07:30:00 6.3 0.6 8.4 4.6 3.6 0.9 6.5 1.9 5.9 0.5 7.6 4.6 15 0 15 165 1.4 0 1.6 1.4 03/13/2006 07:40:00 6.2 0.7 8.4 4.6 3.4 1 6.5 1.5 6.1 0.8 8.4 4.2 15 0 15 165 1.3 0 1.4 1.4 03/13/2006 07:50:00 6.7 0.8 8.8 4.6 3.6 0.9 6.8 1.5 6.7 0.9 8.8 4.2 15 0 15 165 1.2 0 1.4 1.1 03/13/2006 08:00:00 8.2 0.8 9.9 6.5 5.9 1.5 9.5 3 8.1 0.7 10.3 6.5 15 0 15 165 1 0 1.4 0.9 03/13/2006 08:10:00 8.7 0.9 10.7 6.5 6.4 1.6 9.9 3 8.8 0.8 10.7 6.5 15 0 15 165 0.9 0 1.1 0.9 03/13/2006 08:20:00 8.4 0.8 10.7 6.5 6.7 1.1 9.1 3.8 8.3 0.9 10.7 6.1 15 0 15 165 0.8 0 0.9 0.9 03/13/2006 08:30:00 8.5 1 11.1 6.1 6.3 1.8 11.1 3 8.4 1 11.1 6.5 15 0 15 165 0.8 0 0.9 0.7 03/13/2006 08:40:00 8.2 0.9 9.9 5.7 6 1.3 9.1 3.4 8.1 1 10.3 5.7 15 0 15 165 0.7 0 0.9 0.7 03/13/2006 08:50:00 8.7 0.7 11.1 7.2 6.1 1.5 9.9 3.4 8.6 0.7 10.3 6.8 15 0 15 165 0.5 0 0.7 0.4 03/13/2006 09:00:00 7.8 0.7 9.5 6.1 5.2 0.9 7.6 3.4 7.9 0.7 9.5 6.1 15 0 15 165 0.3 0.1 0.7 0.2 03/13/2006 09:10:00 7.5 0.8 9.5 5.3 6.1 1.3 8.8 3 7.5 0.9 9.5 4.6 15 0 15 165 0.2 0 0.2 0.2 03/13/2006 09:20:00 6.8 0.8 8.8 4.9 5.3 1.4 8.4 2.6 6.7 0.8 8.8 5.3 15 0 15 165 0.2 0 0.2 -0.1 03/13/2006 09:30:00 6.9 0.5 8.8 5.7 5.7 0.9 7.6 3.4 6.9 0.6 8.4 5.3 15 0 15 165 0.2 0 0.2 0.2 03/13/2006 09:40:00 6.9 0.7 9.1 5.3 6.1 1 8.8 3 6.7 0.6 8.8 5.3 15 0 15 165 0.2 0 0.2 -0.1 03/13/2006 09:50:00 6.8 0.5 8.4 5.3 5.7 1.2 8 2.6 6.7 0.5 8 5.3 15 0 15 165 0.1 0 0.2 -0.1 03/13/2006 10:00:00 6.6 0.6 8.4 4.9 5.2 1.3 8 2.3 6.5 0.7 8.8 5.3 15 0 15 165 0 0 0.2 -0.1 03/13/2006 10:10:00 7 0.6 8.8 5.7 4.5 1.1 7.2 2.6 7 0.6 9.1 5.7 15 0 15 165 -0.1 0 -0.1 -0.3 03/13/2006 10:20:00 7.5 0.8 10.3 5.3 5.9 1.3 8.8 3 7.5 0.8 9.9 5.7 15 0 15 165 -0.3 0 -0.1 -0.5 03/13/2006 10:30:00 7.1 0.8 9.5 5.3 4.6 1.3 8.4 1.9 7.1 0.8 9.9 4.9 15 0 15 165 -0.4 0 -0.3 -0.5 03/13/2006 10:40:00 6.6 0.8 8.4 4.6 5.4 1.4 7.6 1.9 6.6 0.7 8.8 4.9 15 0 15 165 -0.6 0 -0.5 -0.8 03/13/2006 10:50:00 6.7 0.5 8.4 5.3 5.7 1 8 2.6 6.6 0.6 8.4 5.3 15 0 15 165 -0.7 0 -0.5 -0.8 03/13/2006 11:00:00 7.2 0.6 9.1 5.7 6.6 0.8 8.8 4.6 6.9 0.5 8.8 5.7 15 0 15 165 -0.8 0 -0.5 -0.8 03/13/2006 11:10:00 8.3 1 10.7 6.1 7.8 1.2 10.3 4.6 8 1.1 10.3 5.7 15 0 15 165 -0.7 0 -0.5 -0.8 03/13/2006 11:20:00 7.2 0.6 9.1 5.3 7 0.6 8.8 5.7 6.8 0.6 8.8 5.3 9 15 15 165 -0.4 0.1 -0.3 -0.8 03/13/2006 11:30:00 7.6 0.7 9.1 5.7 7.4 0.7 9.5 4.9 7.2 0.6 8.8 5.3 332 7 338 165 -0.3 0 -0.1 -0.5 03/13/2006 11:40:00 7.4 0.8 9.1 5.3 7.2 0.8 8.8 4.9 7.1 0.7 9.1 5.3 332 9 323 165 -0.3 0 -0.1 -0.3 03/13/2006 11:50:00 6.8 0.9 9.1 4.2 6.7 0.9 9.1 4.2 6.4 0.7 8.4 4.6 325 12 338 165 -0.2 0 -0.1 -0.3 03/13/2006 12:00:00 6.7 1 9.9 3.8 6.6 1 10.3 3.8 6.2 1 9.5 3.4 323 13 340 165 -0.1 0.1 0.2 -0.3 03/13/2006 12:10:00 6.8 0.9 8.8 4.9 6.8 0.9 8.8 4.9 5.7 0.8 8 3.8 312 10 302 165 0.1 0 0.4 -0.1 03/13/2006 12:20:00 6.5 1.1 9.5 4.6 6.5 1.1 9.5 3.8 5.7 0.8 9.1 3.8 316 14 299 165 0.4 0.1 0.7 0.2 03/13/2006 12:30:00 6.7 1.2 9.5 4.2 6.7 1.3 9.5 3.8 5.8 1.1 9.1 3.4 308 21 301 165 0.2 0 0.4 0.2 03/13/2006 12:40:00 5.1 0.9 8.4 2.6 5.2 1 8 2.6 4.9 1.1 8.4 3 296 22 273 165 0.2 0 0.4 0.2 03/13/2006 12:50:00 6.7 1.2 9.9 3 6.8 1.2 9.9 3 6 1.4 10.3 2.3 294 16 279 165 0.1 0 0.4 -0.1 03/13/2006 13:00:00 8.4 1.8 12.6 2.3 8.5 1.9 13.3 2.3 7.7 1.9 13.7 3 289 13 282 165 -0.1 0 0.2 -0.3 03/13/2006 13:10:00 8.5 1.7 12.6 4.2 8.6 1.7 13 4.2 7.6 1.7 13.3 3.8 287 13 279 165 -0.1 0 0.2 -0.3 03/13/2006 13:20:00 10.7 1.3 14.1 7.6 10.9 1.3 14.1 6.8 8.4 1.7 12.6 4.9 293 8 291 165 -0.2 0 -0.1 -0.3 03/13/2006 13:30:00 8.9 1.5 13 4.6 9 1.6 13 4.6 7.4 1.4 11.5 3.4 298 15 312 165 -0.2 0 -0.1 -0.3 03/13/2006 13:40:00 10.6 1.3 13.7 6.8 10.7 1.4 14.1 7.2 8.7 1.7 13 4.6 291 8 284 165 -0.2 0 -0.1 -0.3 03/13/2006 13:50:00 12.1 1.3 16.4 8.4 12.3 1.3 16.8 8 9 1.6 16.8 6.1 298 6 312 165 -0.2 0 -0.1 -0.3 03/13/2006 14:00:00 12.5 1.1 15.3 9.1 12.5 1.1 15.3 9.1 10.9 1.5 14.1 6.8 306 6 305 165 -0.3 0 -0.1 -0.3 03/13/2006 14:10:00 12.6 0.9 15.3 10.7 12.6 1 15.3 10.3 11.4 1.4 14.1 7.2 309 5 307 165 -0.3 0 -0.1 -0.5 03/13/2006 14:20:00 13.9 1 17.2 11.1 13.8 1 17.2 11.1 13 1 15.6 9.1 310 4 304 165 -0.3 0 -0.1 -0.5 03/13/2006 14:30:00 13.6 1.3 17.6 10.3 13.5 1.3 17.6 10.3 13 1.2 17.2 9.5 313 5 300 165 -0.3 0 -0.1 -0.5 03/13/2006 14:40:00 12.8 1.3 16.4 9.5 12.6 1.3 16.8 9.5 11.9 1.5 15.6 7.6 312 7 312 165 -0.3 0 -0.1 -0.3 03/13/2006 14:50:00 12.6 1.3 16.1 9.1 12.4 1.3 16.1 9.1 10.9 1.5 15.3 7.6 309 6 305 165 -0.2 0 -0.1 -0.3 03/13/2006 15:00:00 11.6 1.6 15.3 7.6 11.3 1.5 15.3 7.6 10.4 1.1 13.7 8 314 9 299 165 -0.2 0 -0.1 -0.3 03/13/2006 15:10:00 9.8 1.7 14.5 5.7 9.7 1.7 14.1 5.3 8.1 1.7 14.9 4.2 306 9 297 165 -0.3 0 -0.1 -0.3 03/13/2006 15:20:00 8.7 1.5 13.3 4.9 8.7 1.5 12.6 4.9 7.5 1.4 12.2 4.9 307 9 312 165 -0.1 0 0.2 -0.5 03/13/2006 15:30:00 10.1 1 12.6 7.2 10.1 1 12.6 7.2 7.9 1.2 11.5 4.6 298 9 297 165 -0.1 0 0.2 -0.1 03/13/2006 15:40:00 8.7 1.3 12.2 5.7 8.7 1.3 12.2 6.1 8 1.1 11.1 5.7 325 17 290 165 0 0 0.2 -0.1 03/13/2006 15:50:00 8.6 1 11.5 5.3 8.5 1 11.1 5.7 7.8 1 10.3 5.3 316 14 314 165 0.1 0 0.2 -0.1 03/13/2006 16:00:00 8.6 1.1 11.8 5.7 8.5 1.1 11.8 5.7 7.6 1.1 10.3 5.3 315 15 297 165 0.1 0 0.2 -0.1 03/13/2006 16:10:00 9.5 1.2 12.6 6.1 9.4 1.2 11.8 6.1 7.8 1.1 11.5 4.9 306 10 300 165 0 0 0.2 -0.1 03/13/2006 16:20:00 10 1 12.6 6.8 9.9 1 12.6 7.2 7.7 1 9.9 4.9 304 8 294 165 -0.2 0 -0.1 -0.5 03/13/2006 16:30:00 10.2 1 12.6 7.6 10.1 1 12.2 7.6 8.6 1.2 13.3 6.1 303 9 310 165 -0.3 0 -0.3 -0.5 03/13/2006 16:40:00 9.7 1 12.6 7.6 9.7 0.9 12.6 7.2 8.2 1.2 12.6 5.3 306 9 312 165 -0.6 0.1 -0.3 -0.8 03/13/2006 16:50:00 10.4 0.9 12.2 8 10.4 0.9 12.2 7.6 8.5 1 11.1 6.5 306 7 310 165 -0.8 0 -0.8 -0.8 03/13/2006 17:00:00 10.5 0.9 13 8 10.4 0.9 13 8.4 8 1 11.8 5.7 299 5 306 165 -0.9 0 -0.8 -1 03/13/2006 17:10:00 9.3 1 12.6 6.5 9.2 1 12.6 6.5 7.4 1.2 10.7 4.6 297 9 293 165 -0.9 0 -0.8 -1.2 03/13/2006 17:20:00 8.2 1.2 11.5 5.3 8.2 1.2 11.5 5.3 7.6 1.3 11.1 4.9 319 13 330 165 -0.8 0 -0.5 -0.8 03/13/2006 17:30:00 8.9 1.4 14.1 4.9 8.8 1.5 14.9 4.9 9 1.4 13.3 6.5 335 11 344 165 -0.8 0 -0.5 -0.8 03/13/2006 17:40:00 7.4 1.1 9.9 3.4 7.2 1 9.9 4.2 6.8 1 9.1 3 323 14 338 165 -0.7 0 -0.5 -0.8 03/13/2006 17:50:00 9.4 1.1 11.8 6.5 9.3 1 11.5 6.1 7.4 1.1 10.3 4.2 302 8 290 165 -0.9 0.1 -0.5 -1.2 03/13/2006 18:00:00 7.3 1.3 10.7 4.6 7.2 1.4 10.7 3.8 6.7 1.2 10.3 4.2 322 15 316 165 -1 0 -1 -1.2 03/13/2006 18:10:00 7 1.2 10.3 4.2 6.9 1.2 9.9 3.4 6.3 1 8.8 3.8 320 14 304 165 -1 0 -0.8 -1.2 03/13/2006 18:20:00 5.8 1 9.1 3.8 5.6 1.1 9.1 3.4 5.2 1.1 8.4 3 325 14 314 165 -1.2 0 -1 -1.4 03/13/2006 18:30:00 6.8 1.6 11.1 3 6.4 1.7 11.1 2.3 6 1.5 9.9 3 341 12 346 165 -1.2 0 -1 -1.2 03/13/2006 18:40:00 6.5 1.3 9.9 3.4 5.9 1.3 9.5 2.3 5.8 1.3 8.8 2.6 343 12 356 165 -1.3 0 -1.2 -1.4 03/13/2006 18:50:00 5.7 1.1 8.8 3.4 5.2 1.1 9.1 3 4.8 1.2 8 2.3 337 16 341 165 -1.4 0 -1.2 -1.4 03/13/2006 19:00:00 4.5 1.5 9.5 1.5 3.8 1.4 9.1 1.1 4.1 1.3 7.6 1.5 338 23 340 165 -1.6 0 -1.4 -1.7 03/13/2006 19:10:00 5.1 1.1 9.1 2.3 4.8 1.2 9.1 1.9 4.7 1.2 8.4 2.3 331 17 318 165 -1.7 0 -1.4 -1.9 03/13/2006 19:20:00 5.6 1.2 8.8 3 5.3 1.1 8.4 2.6 5.2 1.2 8.4 2.6 333 14 341 165 -1.7 0.1 -1.4 -1.9 03/13/2006 19:30:00 4.2 1.9 8 0.4 3.5 1.7 8.4 0.4 3.9 1.9 8.4 0.4 339 51 0 165 -2.1 0 -1.9 -2.4 03/13/2006 19:40:00 1.7 1.6 7.2 0.4 1.6 1.5 7.6 0.4 1.5 1.3 7.2 0.4 203 90 309 165 -2.2 0 -2.1 -2.6 03/13/2006 19:50:00 2.3 1.9 9.9 0.4 2 2 9.9 0.4 2.1 1.6 8.8 0.4 348 72 309 165 -2.2 0 -2.1 -2.4 03/13/2006 20:00:00 2.6 1.4 6.8 0.4 2.1 1.3 6.8 0.4 2.1 1.1 5.7 0.4 356 45 325 165 -2.1 0 -1.9 -2.1 03/13/2006 20:10:00 5.5 1.6 9.5 1.9 5 1.7 9.1 1.1 4.4 2 9.1 0.7 337 19 339 165 -2.2 0 -2.1 -2.6 03/13/2006 20:20:00 6.7 1.2 9.1 3.4 6 1.3 9.1 3 6.1 1.1 8.8 3 344 15 0 165 -2.5 0.1 -2.1 -2.6 03/13/2006 20:30:00 10.8 2.3 15.6 4.9 10.5 2.5 15.6 4.2 10.4 2.4 15.3 5.3 339 10 357 165 -2.5 0 -2.4 -2.6 03/13/2006 20:40:00 13.5 2 17.6 8.4 13.5 2.3 18.7 8 13.2 1.9 17.2 8.8 339 6 338 165 -2.5 0 -2.6 -2.6 03/13/2006 20:50:00 14.7 1.7 17.9 9.5 14.7 1.7 18.3 9.5 14 1.5 17.9 9.9 338 7 336 165 -2.6 0 -2.6 -2.8 03/13/2006 21:00:00 13 1.7 17.2 8.4 13 1.9 18.3 7.6 12.4 1.7 16.4 8 337 9 334 165 -2.6 0 -2.6 -2.8 03/13/2006 21:10:00 11.6 1.4 15.6 7.6 11.6 1.5 16.1 7.6 11.2 1.5 17.2 7.2 336 9 341 165 -2.6 0 -2.6 -2.8 03/13/2006 21:20:00 10.9 1.6 15.3 7.2 10.8 1.5 15.3 7.6 10.8 1.6 15.6 6.5 336 9 334 165 -2.5 0 -2.1 -2.8 03/13/2006 21:30:00 11.1 1.3 14.1 7.2 11.1 1.4 14.5 7.2 11.1 1.4 14.1 7.2 332 9 327 165 -2.2 0 -2.1 -2.6 03/13/2006 21:40:00 8 1.4 11.1 3.8 8 1.5 11.8 3.8 8 1.5 11.8 4.2 325 17 320 165 -2.1 0 -1.9 -2.1 03/13/2006 21:50:00 10 1.3 14.5 6.1 10.1 1.3 14.1 6.8 9.5 1.7 13.3 5.3 284 8 295 165 -2.6 0.1 -2.1 -2.8 03/13/2006 22:00:00 11.6 1.2 15.3 8.4 11.6 1.2 15.3 8 11.1 1.7 14.9 6.5 283 7 297 165 -2.6 0 -2.6 -2.8 03/13/2006 22:10:00 10.9 1.1 13.7 7.6 10.9 1.1 13.3 7.6 9.5 1.6 14.1 5.7 291 8 291 165 -2.5 0 -2.4 -2.8 03/13/2006 22:20:00 11.7 0.9 13.7 9.1 11.7 0.8 13.7 9.5 10.6 1.4 13.7 6.8 288 6 294 165 -2.6 0 -2.6 -2.8 03/13/2006 22:30:00 11.5 1.1 14.1 8.4 11.5 1.1 14.1 8.4 10.7 1.5 14.5 6.1 287 6 286 165 -2.6 0.1 -2.1 -2.8 03/13/2006 22:40:00 12 0.9 14.5 9.5 12.1 0.9 14.9 9.1 11.5 1.4 14.9 6.1 285 6 278 165 -2.6 0 -2.6 -2.8 03/13/2006 22:50:00 12.1 1.1 14.5 7.6 12.2 1.1 14.9 7.6 11.7 1.6 16.1 7.2 288 6 289 165 -2.6 0 -2.6 -2.8 03/13/2006 23:00:00 10.6 1.5 13.7 6.5 10.6 1.5 13.7 6.5 9.9 1.7 13.7 6.1 291 8 291 165 -2.5 0.1 -2.1 -2.8 03/13/2006 23:10:00 9.7 1.2 11.8 6.8 9.7 1.1 11.8 6.8 9.1 1.5 13 5.3 291 9 294 165 -2.2 0 -1.9 -2.6 03/13/2006 23:20:00 9.8 1.4 13 5.7 9.7 1.4 13 5.3 8.7 1.5 13.3 4.9 292 10 281 165 -2.3 0 -2.1 -2.6 03/13/2006 23:30:00 9 1.2 11.5 4.2 9 1.1 11.5 4.9 7.9 1.2 11.5 4.6 296 11 292 165 -2.4 0 -2.1 -2.6 03/13/2006 23:40:00 9.8 1 12.2 6.5 9.8 1 11.8 6.8 8.5 1.2 12.2 4.9 295 9 294 165 -2.4 0 -2.1 -2.6 03/13/2006 23:50:00 9.8 1.1 12.2 6.5 9.8 1.1 12.2 6.5 8.6 1.3 11.8 4.9 295 9 296 165 -2.4 0 -2.1 -2.6 03/14/2006 00:00:00 10.1 1 12.2 6.8 10 1.1 12.6 6.5 9.3 1.5 13 5.3 289 9 298 165 -2.5 0 -2.4 -2.8 03/14/2006 00:10:00 11.2 1 13.7 8.8 11.4 0.9 13.7 9.1 11.3 1.1 13.7 7.6 279 7 288 165 -2.8 0 -2.6 -3 03/14/2006 00:20:00 9.2 1.1 11.5 5.3 9.3 1.1 11.8 5.7 9.6 1.5 13 4.9 284 9 279 165 -2.8 0 -2.6 -3 03/14/2006 00:30:00 8.2 1.2 11.1 4.9 8.3 1.1 11.1 4.9 8.3 1.3 11.5 4.2 286 12 282 165 -2.6 0.1 -2.4 -2.8 03/14/2006 00:40:00 6.9 1.1 9.5 4.2 6.8 1.1 9.5 4.2 6.4 1.3 9.9 3 291 13 280 165 -2.4 0.1 -2.1 -2.6 03/14/2006 00:50:00 6.3 1.1 8.8 3 6.4 1.1 8.8 2.3 6.2 1.3 9.1 2.6 284 15 280 165 -2.4 0 -2.1 -2.6 03/14/2006 01:00:00 5.8 1 8 2.6 6 0.9 8 3.4 5.9 1.2 8.4 2.6 278 13 284 165 -2.6 0.2 -2.4 -3 03/14/2006 01:10:00 9.9 1.7 14.5 4.9 9.9 1.9 14.5 4.6 9.4 2.1 13.3 4.6 327 17 341 165 -2.5 0.3 -2.1 -3.3 03/14/2006 01:20:00 10.1 1.8 14.1 6.1 10 1.9 14.5 5.7 9.9 2 14.5 5.7 329 15 336 165 -2.2 0 -1.9 -2.4 03/14/2006 01:30:00 9.3 1.1 13.3 6.8 9.2 1.2 13 6.5 8.2 1.3 12.2 5.3 311 13 307 165 -2.2 0.1 -1.9 -2.6 03/14/2006 01:40:00 8.2 1.2 11.5 4.9 8.1 1.3 11.8 4.6 7.4 1.2 11.1 3.8 309 14 280 165 -2.4 0.1 -2.1 -2.6 03/14/2006 01:50:00 8.6 1.7 13.7 4.2 8 1.7 11.8 3.8 8.6 1.6 14.1 5.3 339 13 5 165 -2.5 0 -2.1 -2.6 03/14/2006 02:00:00 7.1 1.9 12.2 1.5 6.9 2 12.2 1.1 6.9 1.9 11.8 1.5 326 20 329 165 -2.3 0 -2.1 -2.6 03/14/2006 02:10:00 8.9 2.3 13.7 4.2 8.6 2.3 13.7 4.2 8.5 2.7 14.9 4.2 328 21 343 165 -2.4 0.1 -2.1 -2.6 03/14/2006 02:20:00 11.6 2.1 16.8 6.5 11.4 2.3 17.6 6.1 10.8 2 16.1 5.7 335 10 347 165 -2.4 0 -2.1 -2.6 03/14/2006 02:30:00 10 2.1 15.3 4.9 9.4 2.2 15.3 4.9 8.9 2.2 14.1 3.8 337 16 347 165 -2.2 0 -2.1 -2.6 03/14/2006 02:40:00 9.1 2 15.3 4.6 8.5 1.9 13.3 4.6 8.4 1.9 14.1 3.8 339 14 0 165 -2.4 0 -2.1 -2.6 03/14/2006 02:50:00 10 2.1 14.9 5.3 9.4 2.4 15.6 3.8 9.2 2.2 14.9 3.4 339 15 335 165 -2.3 0 -2.1 -2.6 03/14/2006 03:00:00 9.5 1.8 14.5 4.9 9 1.7 14.1 4.6 8.9 1.9 14.1 4.6 337 14 343 165 -2.2 0 -2.1 -2.4 03/14/2006 03:10:00 9 1.6 13.3 5.7 8.9 1.7 13.3 4.9 8.6 1.7 13.3 4.9 333 11 329 165 -2.3 0 -2.1 -2.6 03/14/2006 03:20:00 10 2 14.9 5.7 9.7 2.2 15.3 4.9 9.6 2.1 14.5 5.3 334 12 347 165 -2.2 0.1 -1.9 -2.6 03/14/2006 03:30:00 10.5 1.5 14.5 6.5 10.5 1.7 14.5 5.7 10.5 1.5 14.5 7.2 333 10 338 165 -2 0 -1.9 -2.1 03/14/2006 03:40:00 9.7 1.7 14.5 6.5 9.6 1.6 14.5 6.5 9.4 1.7 14.1 5.3 328 10 319 165 -2.2 0 -1.9 -2.6 03/14/2006 03:50:00 8.1 1.7 12.6 3.4 8.1 1.7 12.6 3 7.7 1.8 12.2 3.4 325 12 327 165 -2.5 0.1 -2.1 -2.6 03/14/2006 04:00:00 7.8 1.7 12.6 3 7.6 1.7 12.6 3 7.4 1.8 11.5 2.3 329 17 323 165 -2.4 0.1 -2.1 -2.6 03/14/2006 04:10:00 11.4 1.9 15.3 6.8 11.3 2.1 15.3 5.7 10.9 2.2 15.6 6.1 331 10 334 165 -2.4 0 -2.1 -2.6 03/14/2006 04:20:00 14 1.7 18.3 9.5 13.3 1.9 18.3 8 13.6 1.8 17.9 8.8 336 12 344 165 -2.3 0 -2.1 -2.6 03/14/2006 04:30:00 12 1.7 16.1 7.6 11.8 1.8 16.8 7.2 10.9 2.1 15.3 5.3 333 11 347 165 -2.5 0.1 -2.1 -2.6 03/14/2006 04:40:00 11.9 1.7 16.8 8 11.5 2.1 17.2 5.7 11.4 2 16.1 6.8 329 13 325 165 -2.2 0.1 -1.9 -2.6 03/14/2006 04:50:00 12.4 1.9 19.5 8.4 12.2 2.1 18.7 7.2 11.9 2 18.7 7.2 336 9 337 165 -2.3 0 -2.1 -2.6 03/14/2006 05:00:00 13.2 1.7 17.6 9.1 13.1 1.7 17.6 8.8 12.9 1.9 17.6 8.8 332 10 334 165 -2.1 0.1 -1.9 -2.4 03/14/2006 05:10:00 11 2.2 17.6 5.3 10.6 2.5 16.8 4.6 10.6 2.4 16.4 3.8 340 15 337 165 -2 0 -1.9 -2.1 03/14/2006 05:20:00 10.6 1.6 15.3 7.2 10 1.8 14.9 5.3 10.4 1.7 14.9 6.5 335 14 315 165 -1.9 0.1 -1.4 -2.1 03/14/2006 05:30:00 11.8 1.6 16.1 9.1 11.6 1.7 16.1 6.8 11.3 1.7 15.6 7.2 329 17 327 165 -1.7 0 -1.4 -1.9 03/14/2006 05:40:00 11.3 2.1 17.9 5.7 11.1 2.3 17.9 4.9 10.6 2.1 19.1 6.5 317 13 319 165 -1.7 0 -1.4 -1.9 03/14/2006 05:50:00 9.7 2.1 15.6 4.6 9.6 2.1 15.3 4.6 8.7 2.1 16.4 3.8 320 17 327 165 -1.8 0 -1.4 -2.1 03/14/2006 06:00:00 7.4 1.7 11.8 1.9 7.2 1.8 12.2 1.5 6.6 1.7 11.1 2.3 324 17 341 165 -2 0 -1.7 -2.1 03/14/2006 06:10:00 9.5 1.6 13.7 4.9 9.3 1.9 13.7 4.2 9.1 1.7 13.3 4.9 331 16 340 165 -1.5 0 -1.2 -1.9 03/14/2006 06:20:00 10.9 2.4 17.6 5.7 10.7 2.5 17.9 5.3 10.4 2.6 16.8 4.9 329 14 336 165 -1.4 0.1 -1.2 -1.7 03/14/2006 06:30:00 9.7 2.2 14.9 5.3 9.5 2.3 15.3 4.6 9.2 2.4 14.9 4.2 322 17 313 165 -1.3 0 -1.2 -1.4 03/14/2006 06:40:00 8 2.5 13.3 1.9 7.7 2.6 13 1.5 7.2 2.5 13 1.1 327 20 328 165 -1.6 0 -1.4 -1.9 03/14/2006 06:50:00 7.6 1.7 13.7 2.3 7 1.9 13 1.5 7 1.8 14.5 3 340 23 20 165 -1.7 0 -1.4 -1.9 03/14/2006 07:00:00 10.4 1.9 15.3 6.1 10.2 2 14.5 4.6 10 1.9 14.1 5.3 335 12 349 165 -1.7 0 -1.4 -2.1 03/14/2006 07:10:00 12.4 2.5 18.3 6.5 11.1 2.5 17.9 4.9 11.8 2.6 19.5 6.1 348 19 45 165 -1.4 0.2 -1 -1.9 03/14/2006 07:20:00 14.5 2.4 20.6 7.6 12.9 2.9 21.8 4.9 14.2 2.4 20.2 6.8 342 18 326 165 -1.3 0 -1.2 -1.4 03/14/2006 07:30:00 13.2 2.4 23.7 8 12.9 2.5 22.6 6.8 12.4 2.3 21.8 6.8 326 14 326 165 -1.2 0 -0.8 -1.4 03/14/2006 07:40:00 12.3 2.2 18.3 6.8 11.9 2.6 18.3 5.7 11.6 2.5 18.3 5.7 326 18 341 165 -1 0 -0.8 -1.4 03/14/2006 07:50:00 11.8 2.4 20.6 7.2 11.7 2.5 20.2 6.8 11.2 2.6 20.6 5.7 323 12 324 165 -1 0 -0.8 -1.2 03/14/2006 08:00:00 12 1.9 18.7 6.8 11.5 2.2 19.5 5.3 12 1.9 18.3 6.5 336 13 314 165 -0.9 0.1 -0.8 -1.2 03/14/2006 08:10:00 15 3.2 23.7 9.1 15.1 3.2 23.7 8.4 14.8 3.2 23.3 9.1 331 9 326 165 -0.9 0 -0.8 -1 03/14/2006 08:20:00 15.6 2.5 22.1 10.3 15.6 2.6 22.1 10.3 15.5 2.6 22.1 9.9 334 10 338 165 -0.8 0 -0.5 -1 03/14/2006 08:30:00 14.7 2.1 20.2 9.1 14.7 2.1 19.9 8.8 14.2 2.2 19.5 8 331 9 343 165 -0.5 0.1 -0.3 -0.8 03/14/2006 08:40:00 15.2 2.5 21.4 8.4 15.1 2.7 21 6.8 14.9 2.6 22.1 8 330 12 344 165 -0.4 0 -0.3 -0.5 03/14/2006 08:50:00 14.8 2.2 21 9.5 14.7 2.3 21 8.4 14.4 2.3 21.4 8.8 331 12 322 165 -0.3 0 -0.1 -0.5 03/14/2006 09:00:00 13.1 2.5 19.1 7.2 13 2.5 19.5 6.8 12.3 2.6 17.9 5.7 328 11 340 165 -0.2 0 0.2 -0.3 03/14/2006 09:10:00 15.8 2.8 24.4 8.8 15.7 2.7 24 8.8 15.1 2.8 22.6 7.6 328 10 321 165 -0.3 0 -0.1 -0.5 03/14/2006 09:20:00 16.9 2.8 26.3 9.5 16.8 2.9 26.8 9.5 15.8 2.7 23.3 7.6 330 13 333 165 -0.2 0 0.2 -0.3 03/14/2006 09:30:00 14.9 2.4 21 8.8 14.8 2.4 21.4 8 13.7 2.5 19.9 8 329 10 328 165 0.1 0.1 0.2 -0.3 03/14/2006 09:40:00 13.6 2.4 20.2 7.6 13.6 2.6 19.9 7.2 12.4 2.7 19.9 6.1 326 15 305 165 0.2 0 0.4 0.2 03/14/2006 09:50:00 15.3 2.9 24 8.4 15 3.3 23.7 7.6 14.5 3.1 22.1 8 333 12 328 165 0.2 0 0.2 -0.1 03/14/2006 10:00:00 15.2 3.1 22.1 7.6 15.2 3.2 22.1 6.8 14.2 3.1 21.4 6.5 332 12 330 165 0.1 0 0.4 -0.1 03/14/2006 10:10:00 16.6 3.1 23.3 9.5 16.4 3.3 23.3 8 15.9 3.2 22.1 7.6 335 14 319 165 0.2 0 0.4 -0.1 03/14/2006 10:20:00 17.3 2.4 22.1 10.7 16.9 3.1 22.1 8 17 2.5 21.8 10.3 335 12 345 165 0.1 0 0.2 -0.1 03/14/2006 10:30:00 14 3.5 23.7 6.5 13.7 3.6 23.7 6.8 13.5 3.8 24 5.7 332 16 333 165 0.2 0.1 0.7 -0.1 03/14/2006 10:40:00 12.2 2.2 17.9 7.6 12 2.3 18.3 6.1 10.9 2.4 17.6 6.1 324 17 312 165 0.4 0 0.7 0.2 03/14/2006 10:50:00 11.1 2.8 22.1 4.9 10.8 2.9 19.1 4.6 10.4 2.7 19.1 3 333 15 353 165 0.7 0 0.9 0.4 03/14/2006 11:00:00 13.6 2.7 21.4 5.7 13.3 3.1 21.8 5.3 13.2 2.7 21 7.2 330 15 330 165 0.4 0.1 0.9 0.2 03/14/2006 11:10:00 12.8 2.5 20.2 7.2 12.7 2.5 19.9 7.2 12.3 2.6 20.6 7.6 327 12 328 165 0.5 0.1 0.9 0.2 03/14/2006 11:20:00 10.8 2.4 17.6 5.3 10.8 2.3 17.9 5.3 10.3 2.5 18.7 4.9 322 14 345 165 0.7 0.2 1.1 0.2 03/14/2006 11:30:00 12.2 2.3 17.2 7.2 12 2.4 17.2 6.5 11.7 2.3 16.8 6.5 331 12 346 165 0.9 0 1.1 0.9 03/14/2006 11:40:00 12.2 2.5 18.7 6.5 11.4 2.9 18.7 4.9 12.1 2.6 18.3 6.8 339 14 344 165 0.8 0 0.9 0.7 03/14/2006 11:50:00 11.2 2.4 16.8 6.8 11.1 2.6 16.8 5.7 11 2.5 17.6 6.5 333 12 338 165 0.9 0 1.1 0.9 03/14/2006 12:00:00 13.1 2.4 19.1 6.5 12.9 2.6 19.5 5.3 12.8 2.4 19.5 6.5 335 10 339 165 0.8 0 1.1 0.9 03/14/2006 12:10:00 13.1 2.7 21.4 6.8 12.7 3.1 21.8 6.1 13.1 2.7 21.4 8 340 13 343 165 0.9 0 1.1 0.9 03/14/2006 12:20:00 14.1 2.2 19.1 8.8 13.5 2.8 18.7 5.7 14 2.3 18.3 7.2 340 11 328 165 0.9 0.1 1.4 0.9 03/14/2006 12:30:00 13.7 1.9 19.1 8.8 13.4 2.2 18.7 7.2 13.5 2 17.9 8 336 10 340 165 0.9 0 1.4 0.7 03/14/2006 12:40:00 13.2 2.1 16.8 7.6 12.8 2.6 17.2 5.3 12.5 2.2 17.6 6.8 337 10 329 165 1.2 0.1 1.6 0.9 03/14/2006 12:50:00 13.6 2.2 19.1 7.2 13.5 2.3 19.1 6.8 12.7 2.3 19.1 6.5 334 10 331 165 1.1 0 1.4 0.9 03/14/2006 13:00:00 13 2 18.3 8 12.9 2.1 18.3 8 12.7 2.3 18.3 7.2 329 10 322 165 1 0.1 1.6 0.9 03/14/2006 13:10:00 11.9 2.2 18.3 6.1 11.8 2.5 18.7 4.9 11.7 2.3 17.9 6.1 334 12 305 165 1.1 0 1.4 0.9 03/14/2006 13:20:00 14.1 2.1 18.7 8.8 13.9 2.3 18.3 8.8 13.8 2.1 19.1 9.9 340 8 349 165 1.2 0 1.4 0.9 03/14/2006 13:30:00 14.1 1.9 18.3 7.6 14.2 2.1 19.1 6.5 13.7 2.1 18.7 6.8 336 7 348 165 1.1 0 1.4 0.9 03/14/2006 13:40:00 13.4 1.9 20.2 9.1 13.1 2.2 20.2 6.8 13.3 1.9 20.6 8.4 340 9 344 165 1.2 0 1.4 0.9 03/14/2006 13:50:00 13 2.4 17.9 6.8 12.3 2.9 18.7 4.9 13.1 2.3 18.3 8 343 11 347 165 1.1 0.1 1.6 0.9 03/14/2006 14:00:00 13.9 2.3 19.9 8 13.5 2.7 20.6 7.6 13.8 2.4 19.5 8.8 343 8 338 165 1.4 0.2 1.8 1.1 03/14/2006 14:10:00 15.4 1.4 20.6 11.5 14.6 2.4 20.2 6.8 15.3 1.6 20.6 11.1 344 8 354 165 1.2 0 1.4 0.9 03/14/2006 14:20:00 13 1.7 16.8 9.1 11.1 2.5 17.2 5.7 12.9 1.9 17.2 8 347 11 341 165 1.4 0.1 1.8 0.9 03/14/2006 14:30:00 14.8 2.1 19.1 8.8 13.6 2.5 18.7 6.5 14.7 2.2 19.1 9.5 345 8 353 165 1.5 0.2 1.8 1.4 03/14/2006 14:40:00 15 1.4 18.7 11.5 14.3 2.4 19.1 7.6 15 1.6 19.1 10.3 342 9 338 165 1.2 0 1.4 1.1 03/14/2006 14:50:00 15.2 1.3 18.3 11.1 15.3 1.4 18.7 11.1 15.1 1.5 18.7 11.1 335 8 333 165 1.2 0 1.4 0.9 03/14/2006 15:00:00 14.8 2.1 19.9 9.5 14.1 2.7 19.5 6.8 14.7 2.4 19.9 8 344 9 349 165 1.1 0 1.4 0.9 03/14/2006 15:10:00 13.9 1.6 17.6 9.5 13.2 2.1 17.9 8.4 13.6 1.9 18.7 8.4 344 10 346 165 1.3 0 1.6 1.1 03/14/2006 15:20:00 14 2.2 19.1 8 14 2.4 19.5 7.6 14 2.2 18.7 8.4 335 9 342 165 0.9 0 1.4 0.9 03/14/2006 15:30:00 13.7 1.8 18.3 8.8 13.3 2.3 18.7 7.2 13.8 1.9 19.9 8.8 339 9 332 165 1 0 1.4 0.9 03/14/2006 15:40:00 10.8 1.8 15.3 6.8 10.6 1.9 16.1 4.9 10.8 2 16.1 6.8 332 15 333 165 1.1 0.1 1.4 0.9 03/14/2006 15:50:00 9.8 1.5 14.5 6.5 9.5 1.5 14.9 6.1 9.6 1.7 15.6 6.1 330 19 338 165 1.1 0.2 1.6 0.9 03/14/2006 16:00:00 9.7 2.1 14.9 4.9 9.3 2.2 14.9 4.2 9.3 2.3 15.3 5.7 329 19 347 165 1.2 0 1.4 0.9 03/14/2006 16:10:00 12 1.8 17.2 7.2 12 1.9 18.7 7.2 12 2 17.2 6.8 335 12 341 165 1.1 0 1.4 0.9 03/14/2006 16:20:00 12 1.9 19.1 8 11.7 2.1 19.9 6.8 11.8 1.9 17.6 7.6 337 11 344 165 1 0 1.4 0.9 03/14/2006 16:30:00 12.7 2.3 19.1 7.6 12.4 2.3 17.9 6.5 12.6 2.1 17.9 8 332 12 347 165 0.8 0 0.9 0.7 03/14/2006 16:40:00 13.4 2.2 19.1 8.8 13.1 2.4 19.9 8 13.4 2.3 19.9 8.4 336 11 344 165 0.7 0 0.9 0.7 03/14/2006 16:50:00 14.4 1.9 17.9 9.5 14.3 2.1 19.1 6.8 14.2 2.2 18.3 8.4 336 8 350 165 0.5 0 0.7 0.4 03/14/2006 17:00:00 14.3 2.4 18.7 6.8 13.8 2.5 19.1 6.5 14.1 2.6 19.1 6.8 336 11 349 165 0.5 0 0.9 0.4 03/14/2006 17:10:00 11 2.7 16.8 5.3 9.8 2.4 16.8 4.6 10.8 2.6 16.8 5.7 346 22 355 165 0.6 0 0.9 0.4 03/14/2006 17:20:00 9.1 2.2 15.6 4.6 8.8 2.4 15.6 4.9 8.9 2.3 16.4 3.4 333 17 340 165 0.7 0 0.9 0.4 03/14/2006 17:30:00 10.4 2.4 16.1 5.7 10.2 2.4 16.4 6.1 10.2 2.6 16.1 4.9 332 13 340 165 0.5 0 0.7 0.2 03/14/2006 17:40:00 12.8 1.8 20.2 9.1 12.6 2.3 21.4 7.6 12.6 2 19.9 8 338 11 344 165 0.3 0.1 0.7 0.2 03/14/2006 17:50:00 13.1 1.5 17.2 9.1 13.1 1.7 17.6 7.6 12.9 1.6 17.9 8.8 336 9 315 165 0.2 0 0.4 0.2 03/14/2006 18:00:00 12.9 2 17.9 6.8 12.9 2 17.6 6.8 12.5 2.3 17.6 6.1 333 8 332 165 0.1 0 0.2 -0.1 03/14/2006 18:10:00 11.7 2.9 18.7 6.1 11.6 3.1 19.9 5.7 11.5 3.1 18.3 4.6 332 13 336 165 -0.1 0 0.2 -0.1 03/14/2006 18:20:00 10.5 2.1 16.4 5.7 10.4 2.3 15.6 4.6 10.1 2.1 15.3 4.9 329 12 321 165 -0.1 0 0.2 -0.3 03/14/2006 18:30:00 11.8 2 15.6 7.6 11.5 2.3 16.1 4.6 11.5 2.3 16.8 6.5 333 12 325 165 -0.2 0 -0.1 -0.3 03/14/2006 18:40:00 12.5 2 17.6 7.6 12.3 2.3 17.2 5.3 11.9 1.9 16.8 6.1 327 13 325 165 -0.3 0 -0.3 -0.5 03/14/2006 18:50:00 10.6 2.4 18.3 5.3 10.4 2.7 18.3 4.2 9.6 2.6 19.1 3 330 15 337 165 -0.7 0.2 -0.3 -1 03/14/2006 19:00:00 12.2 2.1 18.3 6.8 11.9 2.4 18.7 6.1 12 2.1 20.6 6.8 335 10 332 165 -0.9 0 -0.8 -1 03/14/2006 19:10:00 9.8 2.5 15.3 4.6 9.3 2.8 15.6 4.2 9.7 2.6 15.3 4.2 338 15 345 165 -0.9 0 -0.8 -1 03/14/2006 19:20:00 6.7 1.2 10.3 3.4 6.3 1.2 8.8 3.4 6.5 1.4 10.7 3.4 329 20 4 165 -1.1 0 -0.8 -1.2 03/14/2006 19:30:00 6 1.5 9.9 2.3 5.9 1.5 10.3 2.6 5.2 1.7 11.1 1.9 314 16 334 165 -1.3 0.1 -1 -1.4 03/14/2006 19:40:00 6.5 1.7 11.8 3 6.2 1.8 11.8 2.3 5.8 1.9 10.7 1.5 338 22 319 165 -1.3 0 -1.2 -1.4 03/14/2006 19:50:00 9.1 2.1 15.3 4.2 9 2.2 15.3 4.2 8.5 2.4 14.5 2.6 335 11 338 165 -1.3 0 -1 -1.4 03/14/2006 20:00:00 6.8 1.8 11.8 2.6 6.6 1.8 11.5 2.6 6.5 1.9 11.5 2.3 331 12 332 165 -1.1 0 -1 -1.4 03/14/2006 20:10:00 6.7 2.1 12.6 3 6.6 2.1 12.6 2.6 5.8 2.1 12.6 1.9 326 16 321 165 -1.4 0.1 -1.2 -1.4 03/14/2006 20:20:00 4.3 1.5 8.8 0.4 3.9 1.6 9.5 0.4 3.9 1.4 8.4 0.7 353 36 327 165 -1.6 0 -1.4 -1.7 03/14/2006 20:30:00 4.6 1.3 8 1.5 4.2 1.3 7.6 1.1 4.4 1.3 8.4 1.1 354 41 357 165 -1.4 0 -1.2 -1.7 03/14/2006 20:40:00 7 1.6 11.5 3.4 6.7 1.8 11.5 2.6 6.8 1.7 9.9 1.5 338 22 336 165 -1.5 0 -1.4 -1.7 03/14/2006 20:50:00 8.7 1.4 12.6 4.9 8.6 1.5 13 4.6 8.1 1.5 12.2 4.6 324 11 336 165 -1.6 0 -1.4 -1.9 03/14/2006 21:00:00 5.2 1.2 8.8 2.3 4.8 1.2 8.4 1.9 5 1.2 10.3 2.3 340 22 354 165 -1.7 0 -1.4 -1.9 03/14/2006 21:10:00 7.1 1.8 12.6 3 6.8 2.1 12.6 1.9 6.8 1.7 13 3.8 335 15 310 165 -1.6 0 -1.4 -1.9 03/14/2006 21:20:00 8.4 1.9 13.7 4.2 8.1 2.2 13.7 3 8.1 1.6 12.2 4.6 331 18 310 165 -1.6 0 -1.4 -1.7 03/14/2006 21:30:00 7 1.5 11.1 3 6.9 1.5 11.1 3.4 6.6 1.6 10.7 2.6 325 13 328 165 -1.6 0 -1.4 -1.9 03/14/2006 21:40:00 6.6 1.5 10.7 3.4 6.5 1.7 10.7 2.3 6.3 1.4 11.5 3 332 14 321 165 -1.8 0.1 -1.7 -1.9 03/14/2006 21:50:00 6.5 1.5 10.7 3.4 6.4 1.5 10.7 3.4 6.4 1.3 9.9 4.2 325 13 303 165 -1.6 0 -1.4 -2.1 03/14/2006 22:00:00 7.4 1.9 12.6 3.8 6.9 1.8 11.8 3.4 7.1 2 12.6 3.8 331 22 5 165 -1.7 0 -1.4 -1.9 03/14/2006 22:10:00 6.9 1.8 11.1 2.6 6.7 1.9 11.5 2.3 6.7 1.7 10.7 3.4 328 16 320 165 -1.7 0 -1.4 -1.9 03/14/2006 22:20:00 9.3 2 13.3 4.9 9.1 2.1 14.1 4.9 9.1 1.8 14.5 4.9 333 11 322 165 -1.9 0.1 -1.7 -2.1 03/14/2006 22:30:00 9.6 2.2 14.9 4.6 9.4 2.2 14.5 4.9 9.3 2.1 15.3 4.9 325 12 311 165 -1.7 0 -1.4 -1.9 03/14/2006 22:40:00 9.6 1.8 15.6 6.1 9.5 1.8 14.9 6.5 9.1 1.8 14.5 5.7 327 12 316 165 -1.9 0 -1.7 -2.1 03/14/2006 22:50:00 9.7 2.1 16.1 5.7 9.6 2.2 16.1 4.2 9.3 2.2 16.1 4.9 328 13 325 165 -1.9 0.1 -1.7 -2.1 03/14/2006 23:00:00 9.7 1.2 13.3 5.3 9.5 1.3 13.3 4.2 9.5 1.2 12.6 6.1 334 13 342 165 -1.9 0.1 -1.4 -2.1 03/14/2006 23:10:00 10 1.6 13.7 6.8 10 1.7 14.5 6.1 9.6 1.7 13.3 6.1 328 11 323 165 -1.9 0 -1.7 -2.1 03/14/2006 23:20:00 9.4 2.1 14.9 5.3 8.9 2.3 14.9 3.8 9.1 1.9 15.3 5.3 333 15 319 165 -1.8 0 -1.4 -1.9 03/14/2006 23:30:00 6.7 1.5 10.7 3.4 6.3 1.7 10.3 2.3 6.5 1.5 10.3 3.4 332 21 326 165 -1.8 0 -1.7 -1.9 03/14/2006 23:40:00 8.1 1.5 12.2 4.9 8 1.5 11.8 3 8 1.5 11.8 4.9 330 13 311 165 -2 0.1 -1.7 -2.1 03/14/2006 23:50:00 8 1.2 11.8 4.9 7.8 1.4 11.8 3.4 7.8 1.3 12.2 4.6 322 15 326 165 -1.9 0 -1.7 -2.1 03/15/2006 00:00:00 8.2 1.3 11.8 4.6 8 1.5 11.5 4.2 8 1.2 11.5 4.9 330 14 316 165 -1.8 0 -1.7 -2.1 03/15/2006 00:10:00 8.1 2.4 12.2 3.4 7.9 2.4 12.6 3.4 8 2.6 13.7 3.4 330 13 334 165 -2 0.1 -1.7 -2.1 03/15/2006 00:20:00 7.9 1.6 11.5 3.8 7.7 1.8 11.5 3.8 7.9 1.6 11.5 4.2 334 15 333 165 -2.1 0.2 -1.7 -2.6 03/15/2006 00:30:00 7.4 1 9.9 4.9 7.3 1 10.3 4.6 7.3 1 9.9 4.2 333 11 340 165 -2.2 0.2 -1.9 -2.6 03/15/2006 00:40:00 7.9 0.9 10.3 5.7 7.7 1 10.3 4.2 7.6 0.9 9.9 5.3 334 9 343 165 -2.5 0 -2.4 -2.8 03/15/2006 00:50:00 7.9 0.9 10.7 6.1 7.6 1 11.1 3.4 7.7 1 9.9 4.9 340 9 353 165 -2.5 0 -2.1 -2.8 03/15/2006 01:00:00 7.5 0.9 9.5 5.3 7.4 1 9.5 3.4 7.4 0.8 9.1 4.9 334 9 333 165 -2.5 0 -2.4 -2.6 03/15/2006 01:10:00 7.2 0.6 9.1 5.7 7 0.6 9.1 5.3 7.1 0.6 9.1 5.7 323 7 326 165 -2.6 0 -2.4 -2.8 03/15/2006 01:20:00 7.1 0.6 9.5 5.7 6.9 0.6 9.5 5.3 7 0.6 8.8 4.9 325 8 338 165 -2.7 0 -2.6 -2.8 03/15/2006 01:30:00 7.5 0.8 11.1 5.7 7.3 0.9 11.8 5.7 7.3 0.8 11.1 5.7 328 9 340 165 -2.9 0.1 -2.6 -3.3 03/15/2006 01:40:00 7.9 1.3 12.2 5.7 7.7 1.5 12.2 5.3 7.9 1.5 12.2 5.7 327 8 336 165 -2.7 0.3 -2.1 -3 03/15/2006 01:50:00 7.9 1 10.3 6.1 7.7 1 10.3 4.9 7.7 1 10.3 5.3 335 7 339 165 -2.5 0 -2.4 -2.6 03/15/2006 02:00:00 7.7 1.2 11.1 4.9 7.5 1.2 11.1 4.9 7.5 1.2 11.1 5.3 333 11 349 165 -2.6 0 -2.6 -2.8 03/15/2006 02:10:00 8 1.3 11.1 5.3 7.9 1.3 11.5 4.6 7.9 1.3 11.1 5.3 332 9 351 165 -2.6 0 -2.6 -2.8 03/15/2006 02:20:00 8.4 1.5 13 5.3 8.2 1.7 12.6 4.6 8.5 1.5 13.3 5.7 339 11 356 165 -2.6 0.1 -2.4 -2.8 03/15/2006 02:30:00 7.2 1.2 10.3 4.6 7 1.2 10.3 4.6 7.1 1.3 10.7 4.2 333 12 2 165 -2.5 0 -2.4 -2.6 03/15/2006 02:40:00 8.1 1.8 11.8 4.6 8 1.9 11.8 3.8 7.8 1.9 11.5 4.2 331 11 333 165 -2.6 0.1 -2.4 -2.8 03/15/2006 02:50:00 7.1 1.2 10.3 3.8 6.9 1.2 9.9 4.2 6.9 1.2 9.9 4.2 326 14 320 165 -2.5 0 -2.4 -2.8 03/15/2006 03:00:00 8.2 0.9 10.7 5.7 8 1.3 11.5 3.8 8.1 1.1 11.1 5.7 336 9 343 165 -2.6 0 -2.6 -2.8 03/15/2006 03:10:00 7.2 1.4 10.3 3.4 7 1.5 10.3 2.3 7.1 1.5 10.3 3.4 330 12 345 165 -2.5 0 -2.4 -2.6 03/15/2006 03:20:00 6.8 1.2 9.9 4.2 6.3 1.3 9.5 3 6.6 1.2 10.3 3.4 338 17 353 165 -2.5 0 -2.1 -2.8 03/15/2006 03:30:00 7.3 1.7 11.1 3.4 7.1 1.8 11.1 2.6 7 1.9 10.7 2.3 335 11 342 165 -2.5 0.1 -2.6 -2.8 03/15/2006 03:40:00 5.5 1 8.8 3.4 5.4 1 8.4 3.4 5.3 1 8.8 3 318 12 327 165 -2.6 0 -2.6 -2.8 03/15/2006 03:50:00 6.1 0.8 7.6 4.2 6 0.8 7.6 4.2 5.1 0.7 7.2 3.4 307 9 311 165 -2.8 0 -2.6 -2.8 03/15/2006 04:00:00 6.7 0.7 9.1 4.9 6.6 0.7 9.1 4.6 5.7 0.8 7.6 3.8 308 8 291 165 -2.6 0.1 -2.6 -2.8 03/15/2006 04:10:00 6.2 1 9.1 4.2 6.1 1 8.8 3.8 5.4 0.9 8 3.4 305 9 300 165 -2.5 0 -2.4 -2.8 03/15/2006 04:20:00 7 0.8 8.4 4.9 6.9 0.9 8.4 4.6 5.7 1 8 3.4 305 6 306 165 -2.8 0 -2.6 -3 03/15/2006 04:30:00 7 0.6 9.1 4.9 6.9 0.7 8.8 4.9 6.5 0.8 9.1 4.2 310 6 309 165 -2.9 0 -2.8 -3 03/15/2006 04:40:00 6.8 0.7 8.8 4.6 6.7 0.7 8.8 4.2 6.2 0.7 8.4 4.6 312 8 301 165 -3 0 -2.8 -3 03/15/2006 04:50:00 6 0.6 8 4.6 5.9 0.7 7.6 4.2 6 0.6 8 4.2 323 9 323 165 -2.9 0 -2.6 -3 03/15/2006 05:00:00 6.6 0.6 8.4 4.9 6.4 0.6 8 4.6 6.3 0.7 8 4.9 315 8 309 165 -2.8 0 -2.6 -3 03/15/2006 05:10:00 5.5 0.7 7.2 3.8 5.4 0.7 7.2 3.4 5.2 0.6 6.8 3 314 11 319 165 -2.9 0.1 -2.6 -3 03/15/2006 05:20:00 6.9 0.6 8.4 5.3 6.9 0.6 8.4 5.3 5.3 0.6 7.2 3.8 301 6 301 165 -2.8 0 -2.6 -3 03/15/2006 05:30:00 6.1 0.7 8.8 4.2 5.9 0.7 8 4.2 5.7 0.6 7.6 4.2 315 8 320 165 -2.9 0 -2.6 -3 03/15/2006 05:40:00 5.2 0.8 7.2 3.4 5.1 0.8 7.2 3.4 4.7 1 7.2 2.3 310 12 305 165 -2.8 0 -2.6 -3 03/15/2006 05:50:00 6 1 8 3.8 5.9 1 7.6 3.8 4.8 0.9 7.6 3 299 9 292 165 -2.7 0 -2.6 -3 03/15/2006 06:00:00 6.4 0.9 8.4 4.6 6.3 0.9 8 4.2 5.3 0.7 8 3.8 307 9 302 165 -2.9 0 -2.8 -3 03/15/2006 06:10:00 6.4 0.7 7.6 4.6 6.3 0.7 7.6 4.2 5.1 0.7 6.8 3.4 306 7 300 165 -3 0 -2.8 -3.3 03/15/2006 06:20:00 5.5 0.9 8 3 5.4 0.9 7.6 3 4.8 0.8 6.8 2.6 310 12 291 165 -3 0 -2.8 -3.3 03/15/2006 06:30:00 4.8 0.6 6.5 3.4 4.7 0.7 6.8 2.6 4.6 0.6 6.5 3 319 11 321 165 -3.1 0 -2.8 -3.5 03/15/2006 06:40:00 4.7 0.6 6.5 2.6 4.4 0.8 6.5 1.9 4.7 0.6 6.5 3.4 334 11 333 165 -3 0.1 -2.8 -3.5 03/15/2006 06:50:00 5.1 0.8 7.2 3.4 5 0.8 7.2 3 4.9 0.7 6.8 3 335 7 329 165 -3.5 0 -3.3 -3.5 03/15/2006 07:00:00 5.7 0.7 7.2 4.2 5.2 1 7.6 2.3 5.9 0.7 7.6 4.2 346 7 355 165 -3.3 0.2 -3 -3.5 03/15/2006 07:10:00 3.9 0.8 5.7 2.6 3.6 0.8 6.1 1.9 3.8 0.9 6.1 2.6 333 12 338 165 -3.3 0.1 -3 -3.5 03/15/2006 07:20:00 5 1.2 6.8 2.3 4.7 1.3 7.2 1.5 5.1 1.1 6.8 2.6 337 11 329 165 -3.3 0 -3 -3.5 03/15/2006 07:30:00 4.1 1 6.8 2.3 3.8 1.2 7.2 1.1 4.1 1.1 7.2 1.9 345 15 346 165 -3.1 0.1 -2.8 -3.5 03/15/2006 07:40:00 3 0.6 4.9 1.9 2.5 0.8 4.9 0.7 3.1 0.6 4.6 1.9 349 13 340 165 -3.2 0 -2.8 -3.3 03/15/2006 07:50:00 3.8 0.5 5.3 2.6 3.6 0.5 4.9 2.3 3.8 0.5 5.3 2.6 333 10 313 165 -2.6 0.2 -2.1 -3 03/15/2006 08:00:00 4 1 6.5 2.3 3.8 1.2 6.1 1.5 4.1 1 6.1 2.6 332 14 348 165 -2 0.2 -1.7 -2.6 03/15/2006 08:10:00 3.6 0.6 5.3 2.3 3.3 0.7 5.3 1.9 3.8 0.6 5.7 2.3 336 12 335 165 -1.7 0.1 -1.4 -2.1 03/15/2006 08:20:00 3.2 0.6 4.2 1.5 3 0.6 4.2 1.1 3.3 0.5 4.6 1.5 330 12 334 165 -1.5 0 -1.2 -1.7 03/15/2006 08:30:00 2.6 0.6 4.2 1.5 2.3 0.7 3.8 0.7 2.6 0.6 4.2 1.1 329 15 327 165 -1 0.1 -0.5 -1.4 03/15/2006 08:40:00 2.2 0.5 3.8 0.4 2.1 0.6 3.4 0.4 1.8 0.5 3 0.4 298 10 296 165 -0.5 0 -0.1 -0.8 03/15/2006 08:50:00 1.5 0.6 3 0.4 1.2 0.7 2.6 0.4 1.4 0.5 2.6 0.4 320 17 294 165 0.1 0.4 0.7 -0.8 03/15/2006 09:00:00 2.3 0.6 3.4 0.7 2 0.6 3.4 0.4 2.1 0.6 3.4 0.7 327 14 319 165 -0.2 0.2 0.2 -0.5 03/15/2006 09:10:00 3.5 0.6 4.9 1.5 3.4 0.6 4.6 1.5 2.9 0.6 4.2 1.5 308 9 292 165 -0.6 0.3 -0.1 -1.2 03/15/2006 09:20:00 3.6 0.5 5.3 2.3 3.6 0.5 4.9 2.6 3 0.6 4.2 1.5 310 12 304 165 0.4 0.2 0.9 -0.5 03/15/2006 09:30:00 3.2 0.6 4.9 1.5 3.1 0.7 4.9 1.1 3 0.6 4.9 1.9 327 13 341 165 0.8 0.3 1.4 0.4 03/15/2006 09:40:00 3.8 0.9 6.1 1.9 3.6 0.8 6.1 1.9 3.7 0.9 6.5 2.3 329 16 340 165 0.8 0.1 1.4 0.2 03/15/2006 09:50:00 3.7 0.7 5.3 1.5 3.7 0.7 5.3 1.9 3.5 0.7 5.3 1.9 322 10 318 165 0.5 0.3 0.9 -0.1 03/15/2006 10:00:00 3.2 0.6 4.9 1.5 2.7 0.7 4.9 1.1 2.6 0.6 4.2 1.5 347 11 355 165 1.4 0.2 1.8 0.2 03/15/2006 10:10:00 2.6 0.8 4.2 0.7 2.8 0.6 4.2 1.5 2.5 0.6 4.2 0.7 300 30 348 165 0.9 0.3 1.4 0.2 03/15/2006 10:20:00 3.2 0.8 4.6 1.5 3.3 0.7 4.6 1.9 2.9 0.6 4.6 1.9 284 12 288 165 -0.3 0.3 0.2 -1 03/15/2006 10:30:00 3.8 0.6 5.3 2.3 3.8 0.5 4.9 2.6 3 0.5 4.6 1.9 302 7 297 165 -0.8 0.2 -0.3 -1.2 03/15/2006 10:40:00 3.6 0.7 5.3 1.9 3.5 0.7 4.9 1.9 3.2 0.8 5.3 1.5 316 18 320 165 0.5 0.4 1.1 -0.3 03/15/2006 10:50:00 4.4 0.4 5.7 3.8 4.4 0.4 5.3 3.4 3.6 0.6 4.9 2.3 304 9 310 165 -0.3 0.4 0.4 -1 03/15/2006 11:00:00 5.5 0.5 6.8 3.8 5.4 0.5 6.5 3.8 4.4 0.7 6.1 3 304 6 307 165 -0.8 0.2 -0.3 -1.4 03/15/2006 11:10:00 5.3 0.5 6.5 3.4 5.2 0.5 6.5 3.4 4.6 0.6 6.1 3 308 7 310 165 -0.8 0.2 -0.3 -1.2 03/15/2006 11:20:00 5.5 0.4 6.8 4.2 5.5 0.4 6.8 4.2 4.5 0.7 6.5 3 305 4 297 165 -0.8 0 -0.5 -1.2 03/15/2006 11:30:00 5.8 0.5 7.2 4.6 5.7 0.5 7.2 4.6 4.4 0.6 6.1 3 302 5 303 165 -0.6 0 -0.5 -0.8 03/15/2006 11:40:00 6.2 0.5 7.2 4.6 6.1 0.5 7.2 4.6 4.6 0.7 7.6 3 300 4 309 165 -0.8 0 -0.5 -1 03/15/2006 11:50:00 6.4 0.6 7.6 4.6 6.3 0.6 7.6 4.6 5.5 0.9 7.6 3.4 309 8 308 165 -0.3 0.3 0.2 -1.2 03/15/2006 12:00:00 6.4 0.7 8 4.2 6.3 0.7 7.6 4.2 6.1 0.8 7.6 3.8 314 5 310 165 -0.1 0.1 0.2 -0.5 03/15/2006 12:10:00 6.3 0.9 8 3.8 6.3 0.9 8 3.8 5.5 0.9 7.2 3 308 8 302 165 -0.1 0.1 0.2 -0.5 03/15/2006 12:20:00 6.4 0.5 7.6 5.3 6.4 0.5 7.6 5.3 5.1 0.7 6.8 3.4 304 5 298 165 -0.1 0 0.2 -0.5 03/15/2006 12:30:00 5.4 0.7 7.2 3.8 5.4 0.7 7.2 3.8 4.7 0.8 6.8 3 306 6 306 165 0.1 0.2 0.7 -0.3 03/15/2006 12:40:00 5.4 0.5 6.8 4.2 5.4 0.5 6.8 4.2 4.8 0.6 6.5 3 306 5 307 165 0.4 0.2 0.9 -0.1 03/15/2006 12:50:00 4.6 0.6 6.1 3 4.5 0.6 5.7 2.6 4.1 0.7 6.1 2.3 308 11 307 165 0.6 0.3 1.4 -0.1 03/15/2006 13:00:00 4.4 0.7 6.1 2.6 4.4 0.7 6.1 1.9 4.2 0.8 6.1 1.9 313 12 313 165 1.2 0.2 1.6 0.7 03/15/2006 13:10:00 4.3 0.4 5.7 3 4.3 0.4 5.7 3 3.9 0.6 5.3 2.3 288 8 294 165 0.6 0.4 1.6 0.2 03/15/2006 13:20:00 4.9 0.6 6.5 3.4 4.8 0.6 6.5 3.4 4.4 0.8 6.1 2.6 309 9 309 165 0.5 0.2 1.4 -0.1 03/15/2006 13:30:00 4.6 0.8 6.5 2.6 4.6 0.8 6.8 2.6 3.9 1 6.1 1.9 295 10 291 165 0.9 0.1 1.4 0.7 03/15/2006 13:40:00 4.3 0.8 6.5 3 4.3 0.7 6.5 2.6 3.8 0.9 6.5 2.3 298 12 308 165 0.7 0.2 1.1 0.2 03/15/2006 13:50:00 4.1 0.5 5.7 2.6 4 0.5 5.3 2.6 3.9 0.6 5.7 2.3 318 11 319 165 1.2 0.3 1.8 0.7 03/15/2006 14:00:00 4.3 0.8 6.1 1.9 4.3 0.8 6.1 1.5 3.8 0.7 5.7 1.5 299 12 307 165 1.4 0.3 1.8 0.7 03/15/2006 14:10:00 3.5 0.5 4.6 2.3 3.4 0.5 4.9 2.3 3.1 0.5 4.2 1.9 308 9 295 165 1.4 0.4 2.3 0.9 03/15/2006 14:20:00 3.9 0.6 5.3 2.3 3.8 0.6 4.9 1.9 3.8 0.6 5.3 2.3 325 19 330 165 2.2 0.3 2.8 1.6 03/15/2006 14:30:00 4.5 0.8 6.5 2.6 4.4 0.8 6.8 2.6 4.2 0.8 6.5 2.3 316 12 302 165 1.7 0.4 3 0.9 03/15/2006 14:40:00 4.5 1 6.8 2.3 4.4 1 6.5 1.9 4 0.9 6.5 2.3 315 13 322 165 2.2 0.4 2.8 1.4 03/15/2006 14:50:00 5 0.6 6.5 3 4.9 0.6 6.5 2.6 4.7 0.7 6.5 2.6 318 8 323 165 2 0.2 2.6 1.1 03/15/2006 15:00:00 4.6 0.7 6.1 2.6 4.6 0.7 6.1 2.3 4.2 0.7 5.7 2.6 312 10 302 165 1.4 0.2 1.8 0.9 03/15/2006 15:10:00 4.5 0.7 6.1 2.6 4.5 0.7 6.1 2.3 4.3 0.8 6.1 2.3 316 10 326 165 2 0.1 2.3 1.6 03/15/2006 15:20:00 4.9 0.6 6.5 3.4 4.9 0.6 6.5 3.4 4.2 0.7 5.7 2.6 306 6 297 165 1.4 0.2 2.1 0.9 03/15/2006 15:30:00 4 0.6 5.7 2.6 4 0.6 5.7 2.6 3.7 0.7 5.7 1.9 300 17 314 165 1.4 0.2 1.8 0.9 03/15/2006 15:40:00 3.5 0.5 4.9 1.9 3.5 0.5 4.9 2.3 3.3 0.6 4.6 1.9 303 16 313 165 1.6 0.2 2.1 1.4 03/15/2006 15:50:00 2.9 0.7 4.9 1.1 2.9 0.7 4.6 0.7 2.6 0.7 4.2 0.7 299 12 311 165 1.8 0.2 2.3 1.4 03/15/2006 16:00:00 3.2 0.5 4.9 1.5 3.2 0.5 4.6 1.9 3 0.5 4.6 1.5 293 14 283 165 1.6 0.2 2.3 1.1 03/15/2006 16:10:00 3.6 0.4 4.6 2.6 3.6 0.4 4.6 2.3 3.2 0.5 4.6 1.9 297 11 292 165 1.4 0.2 2.1 0.9 03/15/2006 16:20:00 3.6 0.3 4.6 3 3.6 0.3 4.6 2.6 3.1 0.5 4.2 1.9 304 6 302 165 1.1 0.2 1.6 0.7 03/15/2006 16:30:00 2.7 0.5 4.2 1.5 2.7 0.5 4.2 1.5 2.3 0.5 4.2 0.7 296 6 287 165 1.2 0.2 1.6 0.9 03/15/2006 16:40:00 2.9 0.5 4.6 1.5 2.9 0.5 4.6 1.5 2.6 0.5 3.8 1.5 290 12 274 165 1.2 0.2 1.8 0.9 03/15/2006 16:50:00 3.1 0.6 4.9 1.5 3 0.8 4.9 0.7 2.9 0.7 5.3 1.1 334 14 338 165 2.1 0.3 2.8 1.4 03/15/2006 17:00:00 3.6 0.5 4.9 2.3 3.5 0.5 4.9 2.3 3.5 0.5 4.6 1.9 330 6 326 165 2.4 0.3 3 1.6 03/15/2006 17:10:00 3.8 0.6 5.3 2.3 3.7 0.7 4.9 1.9 3.8 0.7 5.3 2.3 331 11 338 165 1.9 0.2 2.3 1.4 03/15/2006 17:20:00 2.7 0.7 4.2 1.1 2.2 0.6 3.8 0.4 2.6 0.8 4.2 1.1 331 30 3 165 1.8 0.2 2.3 1.4 03/15/2006 17:30:00 3.4 0.4 4.6 2.3 3.4 0.4 4.2 2.3 2.7 0.4 4.2 1.5 297 5 298 165 0.8 0.2 1.4 0.2 03/15/2006 17:40:00 3 0.4 3.8 1.5 3 0.4 3.8 1.5 2.8 0.5 3.8 1.9 314 22 312 165 0.7 0.2 1.4 0.2 03/15/2006 17:50:00 3.3 0.5 4.6 2.3 3.2 0.4 4.6 2.3 3.2 0.4 4.2 2.3 322 8 332 165 1 0.1 1.4 0.9 03/15/2006 18:00:00 3.7 0.4 4.6 2.6 3.6 0.4 4.6 2.6 3.6 0.4 4.6 2.6 337 6 348 165 0.8 0 0.9 0.7 03/15/2006 18:10:00 3.4 0.5 4.6 2.6 3.4 0.5 4.2 2.6 3.3 0.5 4.6 2.3 328 6 333 165 0.5 0 0.9 0.4 03/15/2006 18:20:00 3.4 0.6 4.6 1.5 3.3 0.6 4.9 1.5 3.3 0.6 4.6 1.5 330 6 328 165 0.2 0.1 0.7 -0.1 03/15/2006 18:30:00 3.7 0.4 4.6 2.6 3.6 0.4 4.6 2.3 3.5 0.4 4.6 1.9 322 9 313 165 -0.2 0.1 0.2 -0.3 03/15/2006 18:40:00 3.4 0.4 4.2 2.6 3.4 0.4 4.2 2.3 3.4 0.3 4.2 2.3 333 6 338 165 -0.7 0.2 -0.3 -0.8 03/15/2006 18:50:00 3.9 0.5 4.9 2.6 3.9 0.5 4.9 2.6 3.8 0.5 4.9 2.6 333 6 332 165 -1.2 0.2 -0.8 -1.7 03/15/2006 19:00:00 3.4 0.5 4.6 2.6 3.3 0.4 4.6 1.9 3.2 0.5 4.6 1.5 332 9 325 165 -1.6 0 -1.4 -1.9 03/15/2006 19:10:00 3.2 0.4 4.6 2.3 3.2 0.5 4.2 1.9 3.2 0.4 4.2 2.3 336 8 327 165 -1.9 0.1 -1.7 -2.1 03/15/2006 19:20:00 3.1 0.5 4.2 1.9 2.7 0.6 3.8 1.1 3 0.5 4.2 1.9 349 13 336 165 -2.1 0 -1.9 -2.1 03/15/2006 19:30:00 2.9 0.5 4.2 1.9 2.2 0.6 4.2 1.1 3 0.4 4.2 2.3 2 10 353 165 -2 0 -1.9 -2.1 03/15/2006 19:40:00 3.7 0.4 4.9 2.6 2.9 0.7 4.9 1.5 3.7 0.5 4.9 2.6 351 8 351 165 -2.1 0 -1.9 -2.1 03/15/2006 19:50:00 3.1 0.5 4.2 1.9 2.5 0.8 4.2 1.1 3.3 0.4 4.6 2.3 356 13 354 165 -2 0 -1.9 -2.1 03/15/2006 20:00:00 3.3 0.3 3.8 2.3 2.8 0.6 4.2 1.5 3.4 0.3 4.2 2.3 349 7 347 165 -2.1 0 -1.9 -2.1 03/15/2006 20:10:00 3.1 0.3 4.2 1.9 2.6 0.7 4.2 1.1 3.3 0.3 4.2 2.6 347 7 347 165 -2.1 0 -1.9 -2.1 03/15/2006 20:20:00 2.9 0.4 4.2 1.5 2.3 0.7 3.8 0.7 3 0.4 4.2 1.9 352 11 343 165 -2.3 0 -2.1 -2.6 03/15/2006 20:30:00 2.5 0.4 3.8 1.5 1.7 0.7 3.8 0.4 2.8 0.4 3.8 1.9 356 8 350 165 -2.2 0 -2.1 -2.4 03/15/2006 20:40:00 2.6 0.3 3.4 1.9 2.5 0.5 3.4 0.7 2.9 0.3 3.4 2.3 345 5 349 165 -2.4 0.1 -2.1 -2.6 03/15/2006 20:50:00 2.4 0.4 3.4 1.5 1.9 0.6 3.4 0.4 2.5 0.3 3.4 1.9 347 10 356 165 -2.5 0 -2.4 -2.8 03/15/2006 21:00:00 2.2 0.5 3.4 1.5 1.8 0.6 3.8 0.4 2.5 0.4 3.4 1.5 351 7 349 165 -2.6 0 -2.6 -2.8 03/15/2006 21:10:00 2.3 0.3 3.4 1.5 1.8 0.5 2.6 0.7 2.4 0.3 3.4 1.5 347 5 356 165 -2.5 0 -2.6 -2.8 03/15/2006 21:20:00 2.6 0.5 3.8 1.5 1.9 0.7 3.8 0.4 2.7 0.4 3.8 1.9 352 6 350 165 -2.6 0 -2.6 -2.8 03/15/2006 21:30:00 2.1 0.3 3 1.5 1.5 0.6 3 0.4 2.2 0.3 3 1.5 351 8 352 165 -2.6 0 -2.6 -2.8 03/15/2006 21:40:00 2.2 0.3 3 1.5 1.9 0.5 3 0.7 2.2 0.3 3 1.5 338 8 341 165 -2.5 0 -2.6 -2.6 03/15/2006 21:50:00 1.6 0.3 2.3 1.1 1.5 0.3 2.3 0.7 1.8 0.3 2.6 1.1 316 6 326 165 -2.5 0 -2.4 -2.6 03/15/2006 22:00:00 1 0.4 1.9 0.4 0.7 0.4 1.5 0.4 1.4 0.3 1.9 0.7 320 6 312 165 -2.5 0 -2.4 -2.6 03/15/2006 22:10:00 0.7 0.2 1.1 0.4 0.4 0.1 0.7 0.4 1.4 0.2 1.9 1.1 335 0 335 165 -2.5 0 -2.6 -2.8 03/15/2006 22:20:00 1.3 0.4 2.3 0.4 1.1 0.5 2.3 0.4 1.7 0.3 2.6 1.1 343 9 335 165 -2.5 0 -2.4 -2.8 03/15/2006 22:30:00 1.6 0.2 1.9 1.1 1.5 0.4 2.3 0.4 2 0.2 2.6 1.5 344 4 341 165 -2.5 0 -2.4 -2.6 03/15/2006 22:40:00 0.9 0.3 1.9 0.4 0.8 0.3 1.9 0.4 1.5 0.2 1.9 1.1 338 8 338 165 -2.5 0 -2.4 -2.6 03/15/2006 22:50:00 0.5 0.3 1.5 0.4 0.5 0.3 1.5 0.4 1.1 0.3 1.9 0.4 324 0 325 165 -2.5 0 -2.4 -2.6 03/15/2006 23:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.5 0.2 1.1 0.4 324 0 165 165 -2.6 0 -2.4 -2.8 03/15/2006 23:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.7 0.2 1.1 0.4 324 0 165 165 -2 0.2 -1.7 -2.6 03/15/2006 23:20:00 0.4 0 0.7 0.4 0.4 0.1 0.7 0.4 0.9 0.3 1.5 0.4 296 1 296 165 -1.7 0 -1.4 -1.9 03/15/2006 23:30:00 0.4 0.2 1.1 0.4 0.4 0.1 1.1 0.4 1 0.3 1.5 0.4 299 4 296 165 -2.2 0 -1.9 -2.4 03/15/2006 23:40:00 0.4 0.1 0.7 0.4 0.4 0 0.4 0.4 1 0.2 1.5 0.7 307 8 332 165 -2.1 0 -1.9 -2.1 03/15/2006 23:50:00 0.6 0.2 1.1 0.4 0.4 0 0.7 0.4 1.3 0.2 1.5 1.1 349 10 356 165 -2.4 0.1 -2.1 -2.6 03/16/2006 00:00:00 1.1 0.4 1.9 0.4 1.1 0.4 1.9 0.4 1.4 0.3 1.9 0.7 19 5 22 165 -2.5 0 -2.4 -2.6 03/16/2006 00:10:00 1.1 0.3 1.5 0.7 1.2 0.2 1.9 0.7 1.6 0.2 1.9 1.1 22 0 23 165 -2.5 0 -2.4 -2.8 03/16/2006 00:20:00 0.6 0.2 1.1 0.4 0.7 0.2 1.1 0.4 1.3 0.2 1.5 1.1 22 0 22 165 -2.6 0 -2.6 -2.8 03/16/2006 00:30:00 0.4 0 0.4 0.4 0.4 0 0.7 0.4 0.7 0.4 1.5 0.4 22 0 165 165 -2.5 0 -2.1 -2.6 03/16/2006 00:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 22 0 165 165 -3 0.3 -2.6 -3.5 03/16/2006 00:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.5 0.2 0.7 0.4 25 6 165 165 -3 0.4 -2.4 -3.5 03/16/2006 01:00:00 0.4 0.2 0.7 0.4 0.5 0.2 1.1 0.4 0.9 0.2 1.5 0.4 122 51 162 165 -2.2 0.1 -1.9 -2.6 03/16/2006 01:10:00 0.6 0.3 1.1 0.4 0.5 0.3 1.1 0.4 1.1 0.2 1.5 0.4 163 0 162 165 -2 0 -1.7 -2.1 03/16/2006 01:20:00 1.5 0.2 1.9 0.7 1.6 0.2 2.3 0.7 1.8 0.3 2.3 0.7 171 5 165 165 -1.7 0 -1.7 -1.9 03/16/2006 01:30:00 1.2 0.3 1.9 0.4 1.3 0.3 1.9 0.4 1.7 0.2 2.3 1.1 184 3 182 165 -1.7 0 -1.4 -1.9 03/16/2006 01:40:00 1.8 0.3 2.3 1.1 1.8 0.3 2.3 1.1 2.1 0.2 2.6 1.5 181 6 182 165 -1.8 0 -1.4 -2.1 03/16/2006 01:50:00 1.6 0.3 2.3 0.7 1.5 0.4 2.3 0.7 2 0.2 2.6 1.5 204 6 195 165 -2 0 -1.9 -2.1 03/16/2006 02:00:00 0.7 0.4 1.9 0.4 0.6 0.4 1.9 0.4 1.2 0.4 2.3 0.4 206 6 204 165 -1.8 0 -1.4 -1.9 03/16/2006 02:10:00 0.5 0.3 1.5 0.4 0.4 0.2 1.5 0.4 0.8 0.4 1.9 0.4 191 6 187 165 -1.8 0.1 -1.4 -2.1 03/16/2006 02:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 188 0 165 165 -2.2 0 -2.1 -2.4 03/16/2006 02:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 188 0 165 165 -2.2 0 -2.1 -2.4 03/16/2006 02:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0.2 1.1 0.4 171 8 165 165 -2.4 0.2 -2.1 -2.6 03/16/2006 02:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0.2 1.1 0.4 164 0 165 165 -2.9 0.1 -2.6 -3 03/16/2006 03:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 1.2 0.2 1.5 0.7 170 7 165 165 -2.4 0.2 -2.1 -2.8 03/16/2006 03:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 1 0.4 1.5 0.4 179 0 165 165 -2.1 0 -1.9 -2.1 03/16/2006 03:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.5 0.2 1.1 0.4 179 0 165 165 -1.8 0 -1.4 -2.1 03/16/2006 03:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.5 0.2 1.1 0.4 199 3 165 165 -2 0 -1.9 -2.1 03/16/2006 03:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.7 0.2 1.1 0.4 234 8 165 165 -2 0 -1.9 -2.1 03/16/2006 03:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0.1 0.7 0.4 236 0 165 165 -2 0 -1.9 -2.1 03/16/2006 04:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.7 0.4 236 0 165 165 -2.2 0 -1.9 -2.4 03/16/2006 04:10:00 0.4 0.2 1.1 0.4 0.4 0 0.4 0.4 0.9 0.3 1.5 0.4 236 0 236 165 -2 0.1 -1.7 -2.4 03/16/2006 04:20:00 0.5 0.2 1.1 0.4 0.4 0 0.4 0.4 1 0.2 1.5 0.4 235 0 236 165 -1.8 0 -1.7 -1.9 03/16/2006 04:30:00 0.6 0.2 1.1 0.4 0.4 0 0.4 0.4 1 0.2 1.5 0.4 235 0 236 165 -1.7 0 -1.4 -1.9 03/16/2006 04:40:00 0.4 0.1 1.1 0.4 0.4 0 0.4 0.4 0.7 0.2 1.1 0.4 245 19 294 165 -2.2 0.2 -1.7 -2.6 03/16/2006 04:50:00 0.7 0.2 1.5 0.4 0.4 0.1 1.1 0.4 1.1 0.2 1.5 0.7 311 13 322 165 -2.8 0 -2.6 -3 03/16/2006 05:00:00 0.5 0.2 1.1 0.4 0.4 0 0.7 0.4 1 0.2 1.5 0.7 322 0 322 165 -2.9 0 -2.8 -3 03/16/2006 05:10:00 0.4 0.1 0.7 0.4 0.4 0 0.4 0.4 1.1 0.3 1.5 0.4 322 0 322 165 -2.8 0 -2.6 -3 03/16/2006 05:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.5 0.2 1.1 0.4 280 47 165 165 -3 0.1 -2.6 -3.3 03/16/2006 05:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 224 0 165 165 -3.4 0 -3 -3.5 03/16/2006 05:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 224 0 165 165 -3.6 0.1 -3.3 -3.9 03/16/2006 05:50:00 0.7 0.5 1.9 0.4 0.5 0.4 1.5 0.4 1 0.6 2.3 0.4 304 66 25 165 -3.7 0.2 -3 -4.2 03/16/2006 06:00:00 0.8 0.4 1.5 0.4 0.6 0.2 1.1 0.4 1.4 0.2 1.9 0.7 25 4 32 165 -2.4 0.3 -1.9 -3.3 03/16/2006 06:10:00 0.4 0 0.4 0.4 0.4 0 0.7 0.4 0.6 0.3 1.1 0.4 24 5 165 165 -2 0 -1.9 -2.1 03/16/2006 06:20:00 1.2 0.6 2.3 0.4 1.2 0.6 2.6 0.4 1.7 0.6 2.6 0.7 72 6 62 165 -2.1 0 -1.9 -2.1 03/16/2006 06:30:00 2.4 0.4 3 1.9 2.6 0.3 3.4 1.9 2.9 0.3 3.4 2.3 54 3 53 165 -2.4 0.2 -2.1 -2.8 03/16/2006 06:40:00 3.2 0.2 3.4 2.6 3.3 0.2 3.8 3 3.5 0.2 3.8 3 42 4 49 165 -2.7 0 -2.6 -2.8 03/16/2006 06:50:00 2.9 0.2 3.4 2.3 2.9 0.2 3.4 2.6 3.1 0.2 3.4 2.6 31 2 36 165 -2.8 0 -2.6 -2.8 03/16/2006 07:00:00 2.7 0.2 3 2.3 2.6 0.3 3 1.9 2.8 0.2 3.4 2.3 30 2 34 165 -2.8 0 -2.6 -2.8 03/16/2006 07:10:00 2.3 0.2 2.6 1.9 2.3 0.3 3 1.9 2.5 0.3 3 1.9 33 2 31 165 -2.9 0 -2.8 -3 03/16/2006 07:20:00 2.2 0.2 2.6 1.5 2.3 0.3 3 1.5 2.5 0.2 3 1.9 39 3 36 165 -2.6 0.1 -2.4 -3 03/16/2006 07:30:00 2.6 0.4 3.4 1.5 2.7 0.4 3.4 1.5 2.7 0.4 3.4 1.9 43 2 42 165 -2.5 0 -2.1 -2.6 03/16/2006 07:40:00 3.1 0.3 3.8 2.3 3.2 0.3 3.8 2.6 3.2 0.4 3.8 2.3 56 9 65 165 -2.5 0 -2.1 -2.6 03/16/2006 07:50:00 3.5 0.2 3.8 3 3.6 0.2 4.2 3 3.7 0.2 4.2 3.4 66 6 70 165 -2.1 0.1 -1.9 -2.4 03/16/2006 08:00:00 3.3 0.2 3.8 2.6 3.4 0.2 3.8 3 3.5 0.2 4.2 3 43 8 54 165 -2 0 -1.9 -2.4 03/16/2006 08:10:00 3.5 0.2 4.2 3 3.5 0.2 4.2 3 3.8 0.2 4.2 3.4 36 3 39 165 -1.9 0 -1.7 -2.1 03/16/2006 08:20:00 3.2 0.3 4.2 2.6 3.2 0.3 4.2 2.6 3.4 0.2 3.8 3 35 4 48 165 -1.4 0.2 -1 -1.9 03/16/2006 08:30:00 3.2 0.3 3.8 2.6 3.2 0.3 3.8 2.6 3.3 0.2 3.8 2.6 43 2 47 165 -1.3 0 -1.2 -1.4 03/16/2006 08:40:00 3.4 0.3 4.2 2.6 3.5 0.3 4.2 3 3.5 0.3 4.2 2.6 52 6 61 165 -1.6 0.2 -1.2 -1.9 03/16/2006 08:50:00 3.9 0.2 4.2 3 3.8 0.2 4.2 3 3.9 0.2 4.6 3.4 58 4 58 165 -2 0 -1.9 -2.1 03/16/2006 09:00:00 3.7 0.3 4.2 3 3.7 0.3 4.2 3 3.9 0.2 4.2 3.4 56 4 50 165 -1.8 0 -1.4 -1.9 03/16/2006 09:10:00 3.8 0.3 4.6 3 3.8 0.3 4.6 3 3.8 0.3 4.9 3 43 4 52 165 -1.6 0 -1.4 -1.7 03/16/2006 09:20:00 3.8 0.3 4.6 3 3.7 0.4 4.6 2.6 3.9 0.3 4.6 3 38 3 39 165 -1.6 0 -1.4 -1.7 03/16/2006 09:30:00 3.3 0.4 4.6 2.6 3.2 0.4 4.6 2.6 3.2 0.3 3.8 2.3 57 13 75 165 -1.7 0 -1.4 -1.9 03/16/2006 09:40:00 3.5 0.4 4.6 2.6 3.6 0.4 4.6 2.6 3.5 0.4 4.6 2.6 81 6 84 165 -1.7 0 -1.7 -1.9 03/16/2006 09:50:00 3 0.5 4.2 1.9 3 0.5 4.2 1.9 2.9 0.4 4.2 1.9 67 9 84 165 -1.9 0 -1.7 -2.1 03/16/2006 10:00:00 4.7 1.2 7.2 1.9 4.8 1.2 7.6 1.5 4.5 1.3 6.8 1.5 83 17 98 165 -1.7 0.2 -1.2 -2.1 03/16/2006 10:10:00 6.9 0.6 8.4 4.9 6.9 0.6 8.4 4.9 6.5 0.7 8 4.2 112 4 105 165 -1.5 0 -1 -1.4 03/16/2006 10:20:00 5.6 0.5 7.2 4.6 5.7 0.5 7.2 4.6 5.7 0.6 7.6 4.2 119 5 112 165 -1.4 0.1 -0.8 -1.4 03/16/2006 10:30:00 5.3 0.4 6.5 3.8 5.4 0.4 6.5 4.2 5.5 0.4 6.8 4.2 121 5 119 165 -1.4 0.1 -0.8 -1.4 03/16/2006 10:40:00 5.8 0.6 8 4.2 5.9 0.6 7.6 4.6 5.8 0.6 7.6 4.6 121 7 127 165 -1.4 0 -1.2 -1.4 03/16/2006 10:50:00 7.1 0.9 9.1 4.9 7.1 0.8 9.1 4.6 7 0.9 9.1 4.9 126 8 118 165 -1.4 0.1 -0.8 -1.4 03/16/2006 11:00:00 6.8 0.6 8.4 5.3 6.8 0.6 8.8 5.3 6.7 0.6 8 4.9 137 6 134 165 -1.3 0 -1.2 -1.4 03/16/2006 11:10:00 6.6 0.9 8 4.2 6.5 0.8 8.4 4.2 6.7 0.9 8.8 4.6 154 5 157 165 -1.4 0 -1.2 -1.7 03/16/2006 11:20:00 5.1 0.6 6.8 3.4 5.1 0.6 6.8 3.4 5.1 0.7 6.8 1.9 145 11 150 165 -1.6 0 -1.4 -1.7 03/16/2006 11:30:00 4.9 0.7 6.8 3.4 4.9 0.7 7.2 3.4 5 0.8 7.2 3 141 9 150 165 -1.6 0 -1.2 -1.7 03/16/2006 11:40:00 4.5 0.8 6.8 2.6 4.6 0.8 7.2 3 4.4 0.8 6.8 2.6 125 11 128 165 -1.4 0 -1.2 -1.4 03/16/2006 11:50:00 5 1 7.6 2.3 5.1 0.9 8 2.6 4.7 0.9 7.2 2.3 114 11 114 165 -1.4 0 -1.2 -1.4 03/16/2006 12:00:00 6.2 0.8 8 3.4 6.4 0.8 8 3.8 5.9 0.8 8 3.8 117 6 125 165 -1.6 0 -1.4 -1.7 03/16/2006 12:10:00 6.7 1.2 9.1 4.6 6.8 1.2 9.5 4.2 6.5 1.2 9.1 3.8 117 7 128 165 -1.6 0 -1.4 -1.7 03/16/2006 12:20:00 7.3 0.8 9.1 4.9 7.5 0.8 9.1 5.3 7.1 0.8 8.8 5.3 114 6 119 165 -1.3 0 -1.2 -1.4 03/16/2006 12:30:00 6.8 1.1 9.1 4.6 6.9 1.1 9.5 4.6 6.5 1.1 9.1 3.8 112 8 98 165 -1.1 0 -1 -1.2 03/16/2006 12:40:00 7.5 0.8 9.1 4.9 7.7 0.8 9.1 4.9 7.2 0.8 9.1 4.9 112 7 109 165 -1 0 -0.8 -1.2 03/16/2006 12:50:00 7.5 1.2 10.7 4.2 7.7 1.2 10.7 4.2 7.2 1.2 9.9 3.8 108 7 110 165 -1 0 -0.8 -1.2 03/16/2006 13:00:00 7.4 1 9.9 4.9 7.5 1.1 9.9 4.9 7 1 9.5 4.2 107 9 111 165 -1 0.1 -0.8 -1.4 03/16/2006 13:10:00 7.8 0.8 9.5 4.9 8 0.8 9.9 4.9 7.4 0.9 9.5 4.9 100 6 102 165 -0.9 0 -0.5 -1.2 03/16/2006 13:20:00 6.9 0.8 8.8 4.6 7 0.8 9.1 4.6 6.7 0.7 8.4 4.9 107 7 111 165 -0.6 0 -0.5 -0.8 03/16/2006 13:30:00 7.1 1 9.1 4.6 7.2 1 9.5 4.6 6.7 1 9.1 4.6 106 8 100 165 -0.8 0.1 -0.5 -0.8 03/16/2006 13:40:00 5.8 1 8 3.8 6 1 8.8 4.2 5.6 1 8.4 3.8 108 8 110 165 -0.6 0 -0.5 -0.8 03/16/2006 13:50:00 7.1 0.6 8.8 4.9 7.3 0.6 8.8 5.3 6.7 0.7 8.4 4.6 111 7 114 165 -0.8 0.1 -0.5 -0.8 03/16/2006 14:00:00 6.2 0.8 8.4 4.2 6.4 0.8 8 4.2 6 0.8 7.6 3.4 99 8 105 165 -0.8 0.1 -0.5 -1 03/16/2006 14:10:00 5.8 1 8 3.4 5.9 1 8.4 3.8 5.5 0.9 7.2 3.4 106 9 113 165 -0.9 0 -0.8 -1.2 03/16/2006 14:20:00 5.5 0.7 7.2 3 5.7 0.7 7.6 3.4 5.2 0.7 6.8 3 103 9 111 165 -0.9 0 -0.8 -1 03/16/2006 14:30:00 5.6 0.8 8 3.4 5.7 0.8 8 3.4 5.5 0.9 7.6 3.4 118 8 117 165 -0.9 0 -0.8 -1.4 03/16/2006 14:40:00 5.5 0.7 7.2 3.4 5.6 0.7 7.2 3.4 5.3 0.7 7.2 3.4 110 8 99 165 -0.9 0.1 -0.8 -1.4 03/16/2006 14:50:00 5.4 0.7 6.8 3.8 5.6 0.7 7.2 3.8 5.3 0.7 6.8 3 103 7 98 165 -1.1 0.1 -0.8 -1.4 03/16/2006 15:00:00 5.5 0.7 7.2 3.8 5.6 0.7 7.6 3.8 5.4 0.7 7.2 3.4 108 11 120 165 -0.9 0.1 -0.8 -1.2 03/16/2006 15:10:00 5.3 0.6 7.2 3.8 5.4 0.6 7.6 3.8 5.1 0.7 6.8 3.4 96 9 99 165 -0.9 0 -0.8 -1.2 03/16/2006 15:20:00 4.7 1 7.2 3 4.8 1 7.2 3 4.6 0.9 7.2 3 105 9 92 165 -1.2 0 -1 -1.4 03/16/2006 15:30:00 4.3 0.8 6.1 2.6 4.4 0.8 6.1 2.6 4.2 0.7 6.1 2.6 111 9 107 165 -0.9 0.1 -0.8 -1.2 03/16/2006 15:40:00 4.6 0.8 6.5 2.6 4.8 0.8 6.8 2.6 4.7 0.7 6.5 2.6 109 13 102 165 -0.9 0 -0.8 -1 03/16/2006 15:50:00 4.7 0.9 6.8 2.3 4.8 1 6.8 2.6 4.6 0.8 6.5 2.6 105 11 108 165 -0.9 0 -0.8 -1.2 03/16/2006 16:00:00 3.7 0.8 5.3 1.9 3.9 0.8 5.3 2.3 3.7 0.7 5.3 1.9 102 11 92 165 -0.8 0 -0.3 -1 03/16/2006 16:10:00 3.4 0.7 5.3 1.5 3.6 0.6 4.9 2.3 3.5 0.6 5.3 2.3 92 13 99 165 -0.4 0 -0.1 -0.8 03/16/2006 16:20:00 4.4 0.9 6.5 2.3 4.6 0.9 6.8 2.6 4.4 0.8 6.5 2.6 97 11 93 165 -0.9 0.1 -0.5 -1.4 03/16/2006 16:30:00 4.2 0.6 6.1 2.3 4.3 0.7 6.1 2.6 4.2 0.7 6.8 2.6 89 10 115 165 -1 0.1 -0.5 -1.2 03/16/2006 16:40:00 4.2 0.5 5.7 3 4.3 0.6 5.7 3 4.1 0.6 5.7 2.6 98 13 106 165 -0.9 0 -0.8 -1.4 03/16/2006 16:50:00 4.6 0.8 6.8 2.6 4.7 0.7 6.8 2.6 4.4 0.7 6.8 2.6 102 9 97 165 -0.9 0 -0.8 -1.2 03/16/2006 17:00:00 4.3 0.6 5.7 3 4.4 0.6 6.1 3 4.1 0.6 6.8 2.6 90 11 102 165 -1.1 0 -0.8 -1.7 03/16/2006 17:10:00 4.8 0.8 6.8 3 4.9 0.8 6.8 3 4.6 0.8 6.5 3 81 9 79 165 -1.4 0.1 -1.2 -1.7 03/16/2006 17:20:00 4.4 0.8 6.1 2.6 4.6 0.8 6.1 2.6 4.3 0.8 6.1 2.6 83 8 78 165 -1.4 0 -1.2 -1.4 03/16/2006 17:30:00 4.1 0.7 5.7 2.3 4.2 0.7 6.1 2.6 4.1 0.7 6.1 2.3 82 15 79 165 -1.3 0 -1.2 -1.4 03/16/2006 17:40:00 5.1 0.6 6.8 3.4 5.3 0.7 6.8 3.8 4.9 0.7 6.8 3.4 75 8 65 165 -1.6 0 -1.4 -1.9 03/16/2006 17:50:00 4.8 0.6 6.5 3.4 5 0.6 6.8 3.4 4.7 0.6 6.5 3 68 6 70 165 -1.7 0 -1.4 -1.9 03/16/2006 18:00:00 4.5 0.6 6.1 3 4.6 0.6 6.1 3 4.4 0.6 6.1 3 62 7 54 165 -1.6 0 -1.4 -1.9 03/16/2006 18:10:00 5.3 0.8 6.8 3 5.4 0.8 6.8 3 5.1 0.7 6.5 2.6 60 6 64 165 -2 0.2 -1.4 -2.6 03/16/2006 18:20:00 5.1 0.5 6.8 3.8 5.2 0.6 6.8 4.2 4.9 0.5 6.5 3.8 64 6 58 165 -2.2 0.1 -1.9 -2.8 03/16/2006 18:30:00 4.9 0.4 6.5 3.8 5.1 0.4 6.8 3.8 4.7 0.5 5.7 3.4 61 5 51 165 -2.3 0 -2.1 -2.6 03/16/2006 18:40:00 5 0.5 6.1 3.4 5.2 0.5 6.5 3.4 4.8 0.5 5.7 3.4 67 8 56 165 -2.4 0 -2.1 -2.6 03/16/2006 18:50:00 4.5 0.6 6.1 3 4.7 0.6 6.1 3.4 4.3 0.6 6.1 3.4 67 6 73 165 -2.4 0.1 -2.1 -2.8 03/16/2006 19:00:00 5.2 0.4 6.5 4.2 5.4 0.4 6.5 4.6 4.9 0.5 6.1 3.8 59 4 61 165 -2.2 0 -2.1 -2.8 03/16/2006 19:10:00 5.2 0.4 6.5 3.8 5.3 0.4 6.5 4.2 5 0.5 6.5 3.4 56 4 54 165 -2.1 0 -1.9 -2.4 03/16/2006 19:20:00 5.4 0.5 6.5 3.8 5.5 0.5 6.5 4.2 5 0.6 6.5 3.4 54 5 55 165 -2.1 0 -1.9 -2.1 03/16/2006 19:30:00 5.8 0.6 7.2 4.2 5.9 0.6 7.6 4.2 5.3 0.6 7.2 3.4 54 6 46 165 -2 0 -1.9 -2.1 03/16/2006 19:40:00 5.9 0.7 7.6 3.8 6 0.8 7.6 3.8 5.5 0.8 7.2 3.4 53 7 61 165 -2 0.1 -1.7 -2.4 03/16/2006 19:50:00 4.7 0.7 7.2 3 4.8 0.7 7.2 3 4.5 0.7 6.5 2.3 52 8 46 165 -2 0.2 -1.7 -2.4 03/16/2006 20:00:00 5.6 0.6 6.8 3.4 5.7 0.7 6.8 3.8 5.3 0.6 6.5 3.4 52 6 56 165 -2 0.2 -1.7 -2.4 03/16/2006 20:10:00 5.2 0.7 7.2 3.4 5.2 0.7 7.2 3 4.9 0.6 6.8 3.4 50 5 48 165 -2 0.1 -1.7 -2.6 03/16/2006 20:20:00 4.7 0.6 6.1 3 4.7 0.6 6.1 3.4 4.3 0.6 6.1 3 48 8 54 165 -1.9 0.1 -1.7 -2.4 03/16/2006 20:30:00 4.7 0.6 6.1 3 4.7 0.6 6.1 3 4.4 0.6 6.5 3 43 8 50 165 -1.8 0.1 -1.4 -2.4 03/16/2006 20:40:00 5 0.9 7.2 3 5 0.9 7.6 3 4.7 0.9 7.2 3 47 8 43 165 -1.7 0 -1.4 -1.9 03/16/2006 20:50:00 4.9 0.6 6.1 3.4 4.9 0.6 6.1 3.4 4.5 0.6 6.1 3 47 7 42 165 -1.7 0 -1.4 -1.9 03/16/2006 21:00:00 5.2 0.5 6.1 3.8 5.2 0.5 6.5 3.8 5.1 0.6 6.5 3.8 38 5 41 165 -1.6 0 -1.4 -1.9 03/16/2006 21:10:00 5.6 0.3 6.1 4.2 5.6 0.4 6.1 4.6 5.4 0.5 6.5 3.8 37 4 44 165 -1.6 0 -1.4 -1.9 03/16/2006 21:20:00 5.6 0.4 6.5 4.6 5.6 0.4 6.8 4.6 5.5 0.5 6.5 4.2 35 3 33 165 -1.6 0 -1.4 -2.1 03/16/2006 21:30:00 5.2 0.4 6.1 4.2 5.2 0.5 6.1 3.8 5.1 0.6 6.5 3.4 36 4 37 165 -1.7 0.1 -1.4 -2.1 03/16/2006 21:40:00 5.5 0.3 6.5 4.6 5.6 0.4 6.8 4.2 5.4 0.4 6.1 4.2 32 4 32 165 -1.6 0.1 -1.4 -1.9 03/16/2006 21:50:00 5.4 0.6 6.8 3.4 5.4 0.6 6.8 3.4 5.2 0.6 6.5 3.4 28 4 22 165 -1.7 0.2 -1.4 -2.1 03/16/2006 22:00:00 5.2 0.4 6.5 4.2 5.1 0.4 6.5 4.2 5.2 0.4 6.1 4.2 29 3 27 165 -1.7 0.2 -1.4 -1.9 03/16/2006 22:10:00 5.4 0.6 6.8 4.2 5.4 0.7 6.8 4.2 5.3 0.6 6.8 3.8 35 4 43 165 -1.6 0.2 -1.2 -1.9 03/16/2006 22:20:00 6.1 0.5 7.6 4.6 6.1 0.5 7.6 4.6 5.9 0.6 7.2 4.6 39 5 41 165 -1.4 0 -1.2 -1.7 03/16/2006 22:30:00 6.3 0.6 8 4.6 6.3 0.6 8 4.6 6.1 0.7 7.6 4.2 36 6 29 165 -1.4 0 -1.2 -1.4 03/16/2006 22:40:00 5.8 0.7 7.6 3.8 5.8 0.7 8 4.2 5.8 0.7 8 4.2 34 6 38 165 -1.3 0 -0.8 -1.7 03/16/2006 22:50:00 5.9 0.8 7.6 3.4 5.9 0.8 7.6 3.4 5.8 0.8 7.6 3.4 37 6 42 165 -1.3 0 -1 -1.4 03/16/2006 23:00:00 5.8 0.5 6.8 4.6 5.8 0.5 6.8 4.6 5.6 0.6 6.8 4.2 41 5 39 165 -1.2 0 -1 -1.2 03/16/2006 23:10:00 5.1 0.6 6.8 3.4 5.1 0.7 6.8 3 4.9 0.7 6.5 2.6 42 6 51 165 -1.1 0 -0.8 -1.4 03/16/2006 23:20:00 5.5 0.5 6.8 4.2 5.5 0.5 6.8 4.2 5.2 0.5 6.5 3.8 43 5 44 165 -1 0 -0.8 -1.2 03/16/2006 23:30:00 4.7 0.8 6.8 2.6 4.8 0.9 6.8 2.6 4.5 0.8 6.5 3 51 8 43 165 -0.9 0 -0.8 -1.2 03/16/2006 23:40:00 4.2 0.7 5.7 2.6 4.3 0.7 5.7 2.6 4.2 0.6 5.7 2.6 55 8 50 165 -0.9 0 -0.8 -1.2 03/16/2006 23:50:00 5.2 0.8 7.2 2.6 5.4 0.8 7.2 3 5.2 0.7 6.8 3 65 8 63 165 -0.9 0 -0.8 -1.2 03/17/2006 00:00:00 5.3 1 8 2.6 5.4 1 8 3 5.2 1 8.4 3 59 9 54 165 -0.9 0 -0.8 -1 03/17/2006 00:10:00 6.4 1 8.4 3.4 6.6 1 8.8 3.8 6.3 1 8.4 3.8 66 8 63 165 -0.8 0 -0.5 -1 03/17/2006 00:20:00 6 1 8.4 4.2 6.2 1 8.4 4.2 5.9 0.9 8 3.8 66 7 63 165 -0.8 0 -0.5 -0.8 03/17/2006 00:30:00 5.5 0.9 7.6 3 5.5 0.9 7.6 3.4 5.2 0.9 7.6 3 61 9 66 165 -0.8 0 -0.5 -0.8 03/17/2006 00:40:00 5.5 0.8 7.6 3.8 5.6 0.9 7.6 3.8 5.4 0.9 7.2 3.8 62 9 63 165 -0.8 0 -0.5 -0.8 03/17/2006 00:50:00 6.3 0.9 8 4.2 6.4 0.9 8.4 4.2 6.1 0.8 8 4.2 61 6 58 165 -0.8 0 -0.5 -0.8 03/17/2006 01:00:00 7.3 0.6 8.4 5.3 7.4 0.6 8.8 5.3 7.1 0.7 8.4 4.9 60 7 70 165 -1 0.1 -0.8 -1.4 03/17/2006 01:10:00 6 1 8.4 4.2 6.1 1 8.4 3.8 5.7 1 8.4 3.8 53 8 48 165 -1.2 0.1 -1 -1.7 03/17/2006 01:20:00 5.3 0.8 7.2 3.4 5.3 0.8 7.2 3.4 5.1 0.7 6.8 3.4 48 9 44 165 -1 0.1 -0.8 -1.4 03/17/2006 01:30:00 5 0.7 6.8 3 5 0.8 6.8 3 4.9 0.7 6.8 3 44 10 49 165 -1 0.2 -0.8 -1.4 03/17/2006 01:40:00 5.5 1 8.4 3.4 5.6 1 8.8 3 5.2 1 8.8 3.4 56 9 60 165 -0.9 0.2 -0.5 -1.4 03/17/2006 01:50:00 5.4 1.1 8 2.6 5.5 1.1 8 2.6 5.4 1.1 8 2.6 65 11 80 165 -0.8 0 -0.5 -1.2 03/17/2006 02:00:00 5.9 0.9 8.4 3.8 6 1 8.8 3.8 5.8 0.8 9.1 3.8 71 7 78 165 -0.7 0 -0.5 -1 03/17/2006 02:10:00 6 1.3 9.1 3.4 6.1 1.3 9.5 3 5.9 1.2 9.1 3.4 73 8 64 165 -0.8 0.1 -0.5 -1.2 03/17/2006 02:20:00 6.8 1 9.1 4.2 7 1 9.1 4.2 6.7 1 8.8 4.2 75 7 76 165 -0.7 0.1 -0.5 -1.2 03/17/2006 02:30:00 6.1 0.9 8.4 3.8 6.3 0.9 8.4 4.2 6 0.8 7.6 4.2 77 7 78 165 -0.6 0.1 -0.5 -1 03/17/2006 02:40:00 6.3 0.8 8.4 4.2 6.5 0.8 8.4 4.2 6.3 0.7 8 4.6 73 9 78 165 -0.6 0 -0.5 -1 03/17/2006 02:50:00 6.4 0.7 8.4 4.9 6.5 0.8 8.8 4.6 6.2 0.8 8 4.2 72 7 74 165 -0.8 0.2 -0.5 -1.4 03/17/2006 03:00:00 6.5 0.8 8 4.6 6.7 0.8 8.4 4.6 6.5 0.8 8 4.2 63 6 68 165 -0.8 0 -0.5 -1 03/17/2006 03:10:00 6.5 0.9 8.4 4.2 6.6 0.9 8.8 4.6 6.3 0.8 8 4.2 58 7 56 165 -0.9 0.1 -0.8 -1.4 03/17/2006 03:20:00 6 0.8 8 4.2 6.1 0.8 8 4.2 5.8 0.9 8.4 3.8 51 7 49 165 -0.9 0.1 -0.8 -1.4 03/17/2006 03:30:00 5.1 0.7 6.8 2.6 5.1 0.7 7.2 2.6 5 0.7 7.2 2.6 45 9 53 165 -0.9 0 -0.8 -1.4 03/17/2006 03:40:00 4.2 0.6 6.5 2.6 4.2 0.6 6.5 3 4.2 0.6 6.1 3 43 7 44 165 -0.9 0 -0.8 -1 03/17/2006 03:50:00 4.1 0.6 5.7 3 4.2 0.6 5.7 3 4.1 0.7 5.7 2.6 96 27 133 165 -0.8 0.1 -0.5 -1.2 03/17/2006 04:00:00 3.6 1.1 5.7 0.4 3.6 1.1 5.7 0.7 3.7 1 6.1 1.5 123 9 127 165 -0.5 0 -0.3 -0.8 03/17/2006 04:10:00 1.8 0.5 3 0.4 1.9 0.5 3 0.4 2 0.4 3.4 0.7 102 12 100 165 -0.5 0 -0.5 -0.8 03/17/2006 04:20:00 1.1 0.5 1.9 0.4 1.1 0.5 2.3 0.4 1.4 0.4 2.3 0.4 60 20 67 165 -0.7 0.1 -0.5 -1.4 03/17/2006 04:30:00 0.9 0.6 2.3 0.4 0.9 0.6 2.3 0.4 0.7 0.4 2.3 0.4 79 13 95 165 -0.9 0 -0.8 -1 03/17/2006 04:40:00 1.4 0.8 3.4 0.4 1.3 0.9 3.4 0.4 1.1 0.6 2.6 0.4 56 30 37 165 -0.9 0 -0.8 -1.2 03/17/2006 04:50:00 1.7 0.6 3.4 0.4 1.6 0.8 3.8 0.4 1.5 0.5 3.4 0.7 65 19 87 165 -0.9 0 -0.8 -1.2 03/17/2006 05:00:00 2.1 0.6 3 0.4 2.1 0.7 3 0.4 1.9 0.6 3.4 0.4 83 18 93 165 -0.9 0 -0.8 -1.2 03/17/2006 05:10:00 2.4 0.3 3 1.9 2.5 0.3 3.4 1.9 2.8 0.3 3.8 1.9 107 5 106 165 -0.5 0.3 0.2 -1.4 03/17/2006 05:20:00 2.9 0.2 3.4 2.3 2.9 0.2 3.8 2.3 3.2 0.2 3.8 2.6 112 5 107 165 0.1 0.1 0.2 -0.8 03/17/2006 05:30:00 2.9 0.2 3.4 2.3 3 0.2 3.8 2.6 3.2 0.2 4.2 2.6 114 3 119 165 0.2 0.1 0.4 -0.3 03/17/2006 05:40:00 3.2 0.3 3.8 2.6 3.3 0.3 3.8 2.6 3.4 0.3 3.8 2.6 104 6 111 165 0.1 0.1 0.4 -0.3 03/17/2006 05:50:00 2.6 0.3 3.4 1.9 2.6 0.3 3.4 1.9 2.9 0.3 3.4 2.3 103 5 88 165 0.1 0.2 0.4 -0.5 03/17/2006 06:00:00 2 0.5 3 0.4 1.8 0.6 3 0.4 2.2 0.5 3.4 0.4 149 27 106 165 0.2 0.1 0.4 -0.3 03/17/2006 06:10:00 2.1 0.5 3.4 1.1 2 0.5 3.4 0.7 2.2 0.4 3.4 1.5 137 8 129 165 0.1 0 0.2 -0.3 03/17/2006 06:20:00 2.2 0.4 3 1.1 2 0.4 3 1.1 2.1 0.3 3 1.5 136 6 144 165 -0.2 0 -0.1 -0.5 03/17/2006 06:30:00 2.3 0.4 3.4 1.1 2.1 0.4 3.4 1.1 2.3 0.3 3.4 1.5 140 10 144 165 -0.2 0 0.2 -0.5 03/17/2006 06:40:00 2.8 0.3 3.4 1.9 2.6 0.3 3.4 1.9 2.8 0.3 3.4 2.3 147 5 145 165 -0.1 0 0.2 -0.5 03/17/2006 06:50:00 2.7 0.4 3.4 1.9 2.6 0.4 3.4 1.9 2.7 0.3 3.4 1.9 149 4 146 165 0.1 0 0.2 -0.3 03/17/2006 07:00:00 2.8 0.4 3.8 1.9 2.7 0.4 3.8 1.5 2.8 0.3 3.8 1.9 149 5 148 165 0.1 0 0.2 -0.3 03/17/2006 07:10:00 3.1 0.5 4.2 1.9 3 0.5 4.2 1.9 3.1 0.4 4.2 1.9 151 5 154 165 0.1 0 0.2 -0.3 03/17/2006 07:20:00 3.1 0.4 4.2 2.3 3 0.4 3.8 2.3 3.2 0.3 4.2 2.6 153 6 148 165 0.1 0 0.2 -0.3 03/17/2006 07:30:00 3 0.4 3.8 2.3 2.9 0.4 3.8 2.3 3.2 0.3 4.2 2.6 150 5 163 165 0.1 0 0.2 -0.5 03/17/2006 07:40:00 3.1 0.4 4.2 2.3 2.9 0.4 3.8 1.9 3.2 0.3 4.6 2.6 153 4 156 165 0 0 0.2 -0.5 03/17/2006 07:50:00 4.4 0.7 6.1 3 4.3 0.6 5.7 2.6 4.4 0.5 5.7 3 152 4 152 165 0 0 0.2 -0.5 03/17/2006 08:00:00 4.2 0.9 5.7 2.3 4.2 0.9 5.7 2.3 4.3 0.8 5.7 2.6 144 8 154 165 0.1 0 0.2 -0.3 03/17/2006 08:10:00 4.4 0.7 6.1 3 4.3 0.7 6.1 3 4.4 0.6 6.1 2.3 137 6 136 165 0.1 0 0.2 -0.1 03/17/2006 08:20:00 4.2 0.6 6.1 2.3 4.1 0.6 5.7 2.6 4.1 0.5 5.3 3 132 8 135 165 0.1 0 0.2 -0.1 03/17/2006 08:30:00 4.9 1 7.2 2.6 4.9 1 7.6 2.6 4.9 1 7.2 3 125 9 121 165 0.2 0 0.2 0.2 03/17/2006 08:40:00 5.6 0.6 7.2 4.2 5.5 0.6 7.6 4.2 5.6 0.6 7.2 4.2 135 8 134 165 0.1 0 0.2 -0.3 03/17/2006 08:50:00 6.6 1.1 9.1 4.2 6.5 1.1 9.5 3.8 6.5 1.1 9.1 4.2 141 10 126 165 0 0 0.2 -0.3 03/17/2006 09:00:00 5.9 1.5 9.9 2.6 5.8 1.5 10.3 2.6 5.9 1.5 10.3 3 141 10 130 165 0.2 0 0.2 -0.1 03/17/2006 09:10:00 9.5 1.5 12.6 5.3 9.6 1.5 13 4.9 9.1 1.6 12.6 4.2 131 8 130 165 0.4 0.2 0.9 -0.3 03/17/2006 09:20:00 10.2 1 12.6 8 10.3 1 13 7.6 10 1.1 12.2 6.8 134 7 135 165 0.7 0 0.9 0.4 03/17/2006 09:30:00 9.9 0.8 11.8 7.6 9.9 0.8 12.2 7.6 9.7 0.9 12.6 7.2 134 7 135 165 0.8 0 0.9 0.7 03/17/2006 09:40:00 8.5 0.7 10.3 6.8 8.4 0.6 10.3 6.8 8.6 0.7 10.3 6.8 152 4 149 165 0.8 0 1.1 0.9 03/17/2006 09:50:00 7.7 0.4 9.1 6.8 7.6 0.4 8.8 6.8 7.8 0.4 9.1 6.5 153 3 153 165 0.8 0 0.9 0.9 03/17/2006 10:00:00 6.9 0.4 8 6.1 6.8 0.4 7.6 6.1 7 0.3 7.6 6.1 155 2 157 165 0.6 0.2 0.9 -0.1 03/17/2006 10:10:00 6.7 0.4 7.6 5.3 6.6 0.4 7.6 5.3 6.7 0.5 7.6 5.3 151 3 148 165 0.7 0.2 0.9 0.2 03/17/2006 10:20:00 5.9 0.6 7.2 4.6 5.8 0.5 7.2 4.6 6 0.6 7.2 4.6 156 5 151 165 0.7 0 0.9 0.2 03/17/2006 10:30:00 5.7 0.4 7.2 4.6 5.5 0.4 6.8 4.6 5.7 0.4 6.8 4.9 155 3 153 165 0.5 0 0.9 0.2 03/17/2006 10:40:00 5.5 0.4 6.5 4.6 5.3 0.4 6.1 4.2 5.5 0.4 6.1 4.6 160 3 163 165 0.3 0.1 0.7 -0.3 03/17/2006 10:50:00 5.4 0.5 6.1 4.2 5.2 0.4 6.1 4.2 5.3 0.4 6.5 4.2 155 4 154 165 0.2 0.2 0.4 -0.3 03/17/2006 11:00:00 7.4 1.2 10.3 4.9 7.3 1.1 9.9 4.9 7.4 1.2 9.9 4.6 149 5 151 165 0.1 0.1 0.7 -0.3 03/17/2006 11:10:00 8.2 1.5 11.1 5.7 8.1 1.5 11.1 5.3 8.3 1.5 11.5 6.1 152 6 145 165 -0.1 0 0.2 -0.5 03/17/2006 11:20:00 8.6 0.4 9.5 7.2 8.4 0.4 9.1 7.2 8.8 0.5 9.5 7.2 159 8 154 165 0.1 0.1 0.2 -0.3 03/17/2006 11:30:00 8.2 0.5 10.3 6.5 8.1 0.5 10.3 6.1 8.4 0.6 11.1 6.8 158 9 148 165 -0.1 0.1 0.2 -0.5 03/17/2006 11:40:00 9.6 0.8 11.8 7.2 9.6 0.8 11.5 7.2 9.7 0.9 11.8 7.2 149 4 150 165 0.1 0 0.2 -0.3 03/17/2006 11:50:00 9.8 0.7 11.8 8.4 9.9 0.7 11.8 8.4 9.9 0.8 11.8 7.6 152 4 146 165 0.1 0 0.2 -0.3 03/17/2006 12:00:00 9.4 0.8 11.5 7.6 9.3 0.8 11.5 7.2 9.2 0.8 11.1 7.2 160 13 162 165 0.1 0 0.2 -0.3 03/17/2006 12:10:00 8.3 0.8 10.3 6.5 8.2 0.7 10.3 6.5 8.2 0.8 10.3 6.1 160 7 156 165 0.1 0 0.2 -0.3 03/17/2006 12:20:00 7.8 0.9 10.3 6.1 7.8 0.9 9.9 5.7 7.7 1 9.9 5.3 159 9 157 165 0.1 0 0.2 -0.3 03/17/2006 12:30:00 6.6 0.5 7.6 5.3 6.6 0.5 7.6 5.3 6.6 0.5 7.6 5.3 160 3 162 165 0.1 0 0.2 -0.5 03/17/2006 12:40:00 6.9 0.8 10.3 5.3 6.8 0.7 10.3 5.3 6.9 0.6 8.8 5.7 156 5 157 165 0.2 0.1 0.2 -0.5 03/17/2006 12:50:00 7.1 0.6 8.8 5.7 7 0.5 8.4 6.1 7.1 0.6 8.8 5.7 161 7 156 165 0.2 0 0.4 -0.1 03/17/2006 13:00:00 6.4 0.7 8.4 4.9 6.3 0.7 8 4.9 6.3 0.6 8 4.9 154 5 154 165 0.1 0 0.2 -0.1 03/17/2006 13:10:00 7.7 2.2 10.7 3.8 7.8 2.3 10.7 3.8 7.6 2.3 11.1 3.8 145 5 140 165 0.1 0 0.2 -0.3 03/17/2006 13:20:00 10 0.6 11.5 8.4 10.1 0.6 11.5 8.4 9.9 0.8 11.5 7.6 147 3 148 165 0.1 0 0.2 -0.3 03/17/2006 13:30:00 10.8 0.7 12.6 8.4 10.8 0.7 12.6 8.4 10.8 0.9 12.6 8 147 2 146 165 0.1 0.2 0.2 -0.3 03/17/2006 13:40:00 10.7 0.7 12.2 8.4 10.7 0.6 12.2 8.8 10.7 0.7 12.6 8.4 147 3 145 165 0.2 0.1 0.7 -0.3 03/17/2006 13:50:00 10.2 0.6 11.5 8.4 10.2 0.6 11.5 8.8 10.1 0.8 11.8 8 148 3 145 165 0.3 0.1 0.7 -0.1 03/17/2006 14:00:00 10.3 0.6 11.8 8.4 10.3 0.6 11.8 8.8 10.1 0.7 11.5 8 147 4 145 165 0.4 0.1 0.9 0.2 03/17/2006 14:10:00 10.8 0.5 11.8 9.1 10.7 0.5 11.8 9.1 10.8 0.6 11.8 8.4 153 3 158 165 0.4 0.1 0.7 0.2 03/17/2006 14:20:00 10.5 0.6 11.8 8.8 10.5 0.5 11.8 8.4 10.6 0.6 11.8 8.8 152 3 153 165 0.4 0.1 0.7 0.2 03/17/2006 14:30:00 10.6 0.5 11.8 8.4 10.6 0.5 11.8 8.8 10.6 0.6 11.8 9.1 148 3 152 165 0.5 0.2 0.9 0.2 03/17/2006 14:40:00 10.7 0.6 12.6 8.8 10.7 0.6 12.2 8.8 10.6 0.7 12.2 8.4 147 5 142 165 0.6 0.2 0.9 0.2 03/17/2006 14:50:00 11 0.6 13 9.1 11 0.6 13 9.1 11 0.7 12.6 9.1 146 4 142 165 0.7 0.2 0.9 0.2 03/17/2006 15:00:00 11.4 0.5 12.6 9.9 11.4 0.5 12.6 10.3 11.6 0.6 12.6 9.9 151 2 147 165 0.7 0 0.9 0.2 03/17/2006 15:10:00 10.3 0.6 11.5 8.4 10.3 0.6 11.5 8.4 10.4 0.7 11.8 8.4 148 4 151 165 0.7 0.1 0.9 0.4 03/17/2006 15:20:00 10 0.9 12.2 7.6 10 0.8 12.2 7.6 10.1 0.9 12.2 8 142 4 138 165 0.8 0 0.9 0.4 03/17/2006 15:30:00 10.6 0.8 12.6 8 10.6 0.8 12.6 7.2 10.4 1 12.6 7.2 138 6 136 165 0.9 0 1.1 0.7 03/17/2006 15:40:00 10.1 0.8 12.2 8 10.2 0.8 12.2 8.4 10 0.9 12.6 7.2 136 6 135 165 0.9 0.2 1.4 0.7 03/17/2006 15:50:00 10.1 1 12.2 7.6 10.2 1 12.6 7.6 10.2 1.1 13.3 7.6 138 7 146 165 0.9 0.2 1.4 0.7 03/17/2006 16:00:00 11.4 0.9 13.3 8 11.5 0.9 13.7 8.4 11.4 1.1 13.7 8 139 6 141 165 1.1 0.2 1.4 0.7 03/17/2006 16:10:00 12.2 0.7 14.1 9.9 12.4 0.7 14.1 9.9 12.4 0.9 14.1 9.1 139 4 136 165 1.1 0.1 1.4 0.7 03/17/2006 16:20:00 11.8 0.8 13.7 9.5 12.1 0.8 13.7 9.9 12.2 0.8 13.7 9.1 139 4 136 165 0.9 0 1.1 0.7 03/17/2006 16:30:00 11.2 0.8 13.7 9.1 11.5 0.8 13.7 9.9 11.4 0.9 13.7 9.1 141 4 132 165 1.1 0 1.4 0.7 03/17/2006 16:40:00 12.5 0.9 14.5 10.3 12.9 1 15.3 9.9 12.9 1.1 15.3 9.1 141 5 144 165 1.1 0 1.4 0.7 03/17/2006 16:50:00 12.8 0.8 15.3 9.9 13.1 0.8 14.9 10.3 13.2 0.9 15.6 10.3 138 1 137 165 1.2 0 1.4 0.9 03/17/2006 17:00:00 13 0.8 14.9 10.7 13.3 0.8 14.9 11.1 13.3 0.9 15.3 9.9 137 0 138 165 1.1 0 1.4 0.9 03/17/2006 17:10:00 13.1 0.8 14.9 10.7 13.3 0.8 15.3 10.3 13.2 0.8 15.6 11.1 138 0 138 165 1.2 0 1.4 0.9 03/17/2006 17:20:00 12.9 0.8 14.9 11.1 13.1 0.7 14.9 11.1 13.1 0.8 15.3 11.1 137 0 137 165 1.2 0 1.4 0.9 03/17/2006 17:30:00 14 0.9 17.2 11.8 14 0.9 16.8 12.2 14.1 1 16.8 11.1 138 0 137 165 1.2 0 1.4 0.9 03/17/2006 17:40:00 13.3 0.8 15.3 11.1 13.3 0.8 15.3 11.5 13.4 1 16.1 10.3 138 0 137 165 1.2 0 1.4 0.9 03/17/2006 17:50:00 14.1 0.9 16.4 11.5 14 0.9 16.4 11.5 14.1 1.1 16.4 11.1 138 0 137 165 1.2 0 1.4 0.9 03/17/2006 18:00:00 14.6 1.1 16.8 11.5 14.4 1 16.4 11.5 14.6 1.2 17.9 10.3 138 0 137 165 1.2 0 1.4 0.9 03/17/2006 18:10:00 13.5 1 16.1 11.1 13.3 1 15.3 11.1 13.4 1.1 16.8 10.3 137 0 138 165 1.2 0 1.4 0.9 03/17/2006 18:20:00 12.6 1.3 16.4 9.5 12.4 1.3 16.1 9.5 12.5 1.2 16.4 9.5 138 0 137 165 1.2 0 1.4 0.9 03/17/2006 18:30:00 12.4 1.3 16.1 9.5 12.1 1.3 15.6 9.1 12 1.4 15.6 8 137 0 137 165 1.1 0 1.4 0.9 03/17/2006 18:40:00 12.5 1 14.5 8.8 12.1 1 14.1 8.8 12 1 14.9 9.1 137 0 137 165 1.1 0 1.4 0.7 03/17/2006 18:50:00 10.9 1.1 13.7 8 10.9 1 13.3 8.4 10.6 1.2 13.7 7.6 137 0 137 165 1 0 1.1 0.7 03/17/2006 19:00:00 10.2 1.2 14.5 7.2 10.2 1.2 14.1 7.2 9.8 1.3 14.1 6.1 137 0 137 165 1.1 0 1.4 0.9 03/17/2006 19:10:00 9.9 1 12.6 6.5 9.8 1 12.6 7.2 9.2 1.2 12.6 6.5 137 0 137 165 1.1 0 1.4 0.9 03/17/2006 19:20:00 9.8 1 13 6.8 9.6 1 12.6 6.5 9.1 1.1 12.6 6.5 137 0 137 165 1.2 0 1.4 0.9 03/17/2006 19:30:00 9.1 0.7 11.1 7.2 8.9 0.7 11.1 6.8 8.6 0.8 11.1 6.5 137 0 137 165 1.2 0 1.4 0.9 03/17/2006 19:40:00 8.7 1.1 11.1 6.1 8.6 1.1 11.1 5.7 8.4 1.1 10.7 5.3 137 0 137 165 1.2 0 1.4 0.9 03/17/2006 19:50:00 8.4 1 11.1 6.1 8.5 1.1 11.5 6.1 8.3 1.1 10.7 6.1 137 0 137 165 1.1 0 1.4 0.7 03/17/2006 20:00:00 8.5 1 12.2 6.5 8.8 1 11.8 6.8 8.4 1.1 10.7 5.7 137 0 137 165 1.1 0 1.4 0.7 03/17/2006 20:10:00 7.4 1 9.9 5.3 7.7 1.1 10.3 5.3 6.9 1.4 10.7 3.8 137 0 137 165 1.1 0 1.4 0.7 03/17/2006 20:20:00 6.8 1 9.1 4.2 7 1 9.1 4.6 5.6 1.4 8.8 1.5 137 0 137 165 1.2 0 1.4 0.9 03/17/2006 20:30:00 7.9 0.6 9.9 6.5 7.5 0.6 9.1 6.1 6.6 0.8 8.4 4.6 137 0 137 165 1.2 0 1.4 0.9 03/17/2006 20:40:00 7.5 0.7 9.9 5.3 7.1 0.8 9.1 5.3 6 0.9 8.4 3.8 137 0 137 165 1.1 0.1 1.4 0.9 03/17/2006 20:50:00 7.4 0.7 8.8 5.3 7 0.7 8.4 4.6 6 0.8 8 3.4 137 0 137 165 1.1 0.1 1.4 0.9 03/17/2006 21:00:00 7.4 0.7 9.1 5.3 6.9 0.8 8.8 4.6 5.7 0.9 8 3.4 137 0 137 165 1.2 0.2 1.4 0.9 03/17/2006 21:10:00 7.1 0.6 9.5 5.3 6.6 0.7 8.8 4.6 5.5 0.8 7.6 2.6 137 0 137 165 1.2 0.2 1.4 0.9 03/17/2006 21:20:00 6.9 0.6 8.4 5.3 6.4 0.6 8.4 4.6 5.3 0.8 7.2 2.3 137 0 137 165 1.2 0.1 1.6 0.9 03/17/2006 21:30:00 6.2 0.6 8 4.6 5.6 0.7 7.6 3.4 4.7 0.8 7.2 2.6 137 0 138 165 1.3 0.1 1.6 0.9 03/17/2006 21:40:00 6.4 0.9 9.1 4.9 5.6 0.9 8 3.8 4.8 1.1 8 2.3 137 0 137 165 1.4 0.1 1.6 0.9 03/17/2006 21:50:00 5.7 0.6 6.8 3.4 4.9 0.8 6.5 2.3 1.8 1.7 5.3 0.4 137 0 137 165 1.4 0 1.6 1.1 03/17/2006 22:00:00 5.8 0.4 6.8 4.9 5.1 0.5 6.5 4.2 0.4 0 0.4 0.4 137 0 137 165 1.4 0.1 1.6 1.1 03/17/2006 22:10:00 5.6 0.4 6.5 4.6 5 0.5 6.1 3.8 0.4 0 0.4 0.4 137 0 137 165 1.5 0 1.6 1.1 03/17/2006 22:20:00 5.1 0.6 6.5 3.8 4.4 0.7 6.1 2.6 0.4 0 0.4 0.4 137 0 137 165 1.5 0 1.8 1.4 03/17/2006 22:30:00 5.2 0.5 6.8 4.2 4.3 0.5 5.7 3 0.4 0 0.4 0.4 137 0 137 165 1.6 0 1.8 1.4 03/17/2006 22:40:00 5.4 0.6 6.8 3.4 4.6 0.7 6.1 2.6 0.4 0 0.4 0.4 137 0 137 165 1.6 0 1.8 1.4 03/17/2006 22:50:00 5.3 0.6 6.5 3.4 4.8 0.6 6.5 3 0.4 0 0.4 0.4 137 0 137 165 1.7 0 1.8 1.4 03/17/2006 23:00:00 5.1 0.7 6.8 3 4.9 0.6 6.1 3 0.4 0 0.4 0.4 137 0 137 165 1.9 0 1.8 1.6 03/17/2006 23:10:00 4.5 0.4 5.7 3 4.5 0.4 5.7 3.4 0.4 0 0.4 0.4 138 0 138 165 1.9 0 2.1 1.6 03/17/2006 23:20:00 3.7 0.4 4.9 2.6 3.7 0.4 4.9 2.6 0.4 0 0.4 0.4 135 5 138 165 2.1 0 2.3 1.6 03/17/2006 23:30:00 3 0.4 4.2 1.5 3 0.4 4.2 1.5 0.4 0 0.4 0.4 129 8 130 165 2.2 0 2.3 1.8 03/17/2006 23:40:00 2.8 0.5 3.8 1.9 2.9 0.4 3.8 1.5 0.4 0 0.4 0.4 124 8 114 165 2.3 0 2.3 2.1 03/17/2006 23:50:00 3.5 0.5 5.3 2.3 3.6 0.4 4.6 2.6 0.4 0 0.4 0.4 126 9 106 165 2.3 0 2.6 2.1 03/18/2006 00:00:00 3 0.6 4.6 1.5 3.1 0.6 4.6 1.5 0.4 0 0.4 0.4 128 8 122 165 2.4 0 2.6 2.1 03/18/2006 00:10:00 2.7 0.4 3.8 1.5 2.9 0.4 4.2 1.9 0.4 0 0.4 0.4 125 6 129 165 2.4 0.1 2.6 1.8 03/18/2006 00:20:00 3.1 0.4 4.6 1.9 3.2 0.5 4.6 1.9 0.4 0 0.4 0.4 126 7 123 165 2.4 0.1 2.6 1.8 03/18/2006 00:30:00 2.8 0.5 4.2 1.5 3 0.5 4.2 1.5 0.4 0 0.4 0.4 120 9 126 165 2.3 0 2.6 1.8 03/18/2006 00:40:00 2.3 0.7 3.8 1.1 2.4 0.8 4.2 0.7 2 1 3.8 0.4 122 6 114 165 2.1 0.1 2.3 1.6 03/18/2006 00:50:00 0.9 0.5 2.3 0.4 0.8 0.5 2.3 0.4 1.1 0.5 2.3 0.4 111 9 114 165 2.1 0 2.3 1.6 03/18/2006 01:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0.1 0.7 0.4 86 19 165 165 2 0 2.3 1.8 03/18/2006 01:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0.1 0.7 0.4 23 14 165 165 1.8 0 1.8 1.6 03/18/2006 01:20:00 0.4 0.1 0.7 0.4 0.4 0 0.4 0.4 0.9 0.2 1.5 0.4 4 7 1 165 1.8 0 1.8 1.4 03/18/2006 01:30:00 0.4 0.1 0.7 0.4 0.4 0 0.4 0.4 1 0.2 1.5 0.4 14 1 14 165 1.7 0 1.8 1.4 03/18/2006 01:40:00 0.4 0.1 1.1 0.4 0.4 0 0.4 0.4 0.8 0.3 1.5 0.4 5 8 357 165 1.8 0 1.8 1.4 03/18/2006 01:50:00 0.7 0.4 1.5 0.4 0.4 0 0.4 0.4 1.3 0.2 1.9 0.7 2 6 7 165 1.8 0.1 1.8 1.4 03/18/2006 02:00:00 0.9 0.3 1.5 0.4 0.4 0 0.4 0.4 1.3 0.2 1.9 0.7 354 1 355 165 1.8 0 1.8 1.4 03/18/2006 02:10:00 1.2 0.2 1.9 0.7 0.4 0.2 1.1 0.4 1.4 0.2 1.9 1.1 348 6 344 165 1.8 0 1.8 1.4 03/18/2006 02:20:00 1.5 0.4 2.3 0.7 1.2 0.5 2.3 0.4 1.6 0.2 2.3 1.1 323 16 294 165 1.9 0 2.1 1.6 03/18/2006 02:30:00 1.8 0.3 2.3 0.7 1.6 0.3 2.3 0.7 1.8 0.4 2.6 0.7 303 7 305 165 1.8 0 1.8 1.4 03/18/2006 02:40:00 1.2 0.3 1.9 0.4 1.1 0.3 1.9 0.4 1.5 0.3 2.3 0.7 304 6 301 165 1.7 0 1.8 1.4 03/18/2006 02:50:00 1.9 0.4 2.6 1.1 1.8 0.4 2.6 0.7 1.7 0.3 2.3 1.1 301 4 296 165 1.7 0 1.8 1.4 03/18/2006 03:00:00 2.6 0.4 3.4 1.5 2.4 0.4 3 1.5 2 0.4 3 1.5 298 5 295 165 1.7 0 1.8 1.4 03/18/2006 03:10:00 3.1 0.4 4.2 2.3 2.9 0.4 3.8 1.9 2.6 0.4 3.4 1.9 301 5 303 165 1.7 0 1.8 1.4 03/18/2006 03:20:00 3.8 0.3 4.6 3 3.6 0.3 4.2 2.6 3.3 0.4 4.6 2.3 305 2 304 165 1.7 0 1.8 1.4 03/18/2006 03:30:00 4.4 0.6 5.3 3 3.5 0.5 4.6 2.6 3.6 0.4 4.6 2.6 304 0 304 165 1.6 0 1.8 1.4 03/18/2006 03:40:00 4.4 0.6 5.3 2.6 3.8 0.6 4.9 1.9 4.3 0.5 5.7 2.6 304 0 304 165 1.4 0.1 1.6 1.4 03/18/2006 03:50:00 3.3 0.5 4.6 2.3 2.9 0.5 4.2 1.9 3.9 0.5 4.9 2.6 304 0 304 165 1.3 0 1.4 1.4 03/18/2006 04:00:00 3.1 0.6 4.2 1.5 2.6 0.6 4.2 0.7 3.5 0.5 4.9 2.3 304 0 304 165 1.2 0 1.4 1.1 03/18/2006 04:10:00 3 0.4 4.6 2.3 2.6 0.4 3.8 1.9 3.5 0.4 4.6 2.3 304 0 304 165 1 0 1.4 0.9 03/18/2006 04:20:00 3.5 0.5 4.6 2.3 3 0.5 4.2 1.5 3.9 0.5 5.3 3 304 0 304 165 0.9 0 1.1 0.9 03/18/2006 04:30:00 4 0.6 5.3 2.6 3.1 0.8 4.9 1.5 4.6 0.6 5.7 3 304 0 304 165 0.9 0 1.1 0.9 03/18/2006 04:40:00 3.2 0.6 4.9 2.3 2.8 0.7 4.6 0.7 3.6 0.6 4.9 2.3 304 0 304 165 0.9 0 1.1 0.9 03/18/2006 04:50:00 2.3 0.3 3 1.5 1.8 0.5 2.6 0.4 2.8 0.3 3.8 1.9 304 0 304 165 0.9 0 1.1 0.9 03/18/2006 05:00:00 2.8 0.5 4.6 1.5 2.2 0.7 3.8 0.4 3.3 0.5 4.9 2.3 304 0 304 165 0.8 0 0.9 0.7 03/18/2006 05:10:00 3.5 0.6 4.9 1.9 2.7 0.8 4.6 1.1 4.1 0.6 5.3 2.6 304 0 304 165 0.8 0 0.9 0.7 03/18/2006 05:20:00 2.7 0.3 3.4 1.9 2.2 0.4 3 0.7 3.2 0.4 4.2 2.3 304 0 304 165 0.8 0 0.9 0.7 03/18/2006 05:30:00 3.7 0.6 4.9 2.6 3.4 0.6 4.9 2.3 4.1 0.6 5.7 3 304 0 304 165 0.8 0 0.9 0.7 03/18/2006 05:40:00 3.6 0.6 5.3 2.3 3.1 0.7 5.3 1.9 3.8 0.7 5.7 2.3 304 0 304 165 0.8 0 0.9 0.7 03/18/2006 05:50:00 3.8 0.5 4.9 2.6 3.4 0.5 4.9 2.3 4.1 0.5 5.7 3 304 0 304 165 0.8 0 0.9 0.7 03/18/2006 06:00:00 3.1 0.4 4.2 2.3 2.8 0.4 4.2 1.9 3.5 0.4 4.6 2.6 304 0 304 165 0.8 0 0.9 0.7 03/18/2006 06:10:00 3.7 0.6 4.9 2.3 3.3 0.6 4.6 2.3 4 0.6 5.3 2.6 304 0 304 165 0.7 0 0.9 0.4 03/18/2006 06:20:00 4 0.8 5.3 2.3 3.8 1 5.7 1.9 4.2 0.8 5.7 2.6 304 0 304 165 0.8 0 0.9 0.7 03/18/2006 06:30:00 1.9 0.4 3 0.7 1.8 0.4 3 0.4 2.2 0.4 3 1.1 304 0 304 165 0.7 0 0.9 0.7 03/18/2006 06:40:00 2.1 0.3 2.6 1.5 2 0.3 3 1.5 2.2 0.3 3 1.1 304 0 304 165 0.7 0 0.9 0.4 03/18/2006 06:50:00 2.8 0.6 4.6 1.5 2.7 0.6 4.6 1.5 2.6 0.6 5.3 1.9 304 0 304 165 0.7 0 0.9 0.4 03/18/2006 07:00:00 3.9 0.5 5.3 2.6 3.8 0.5 5.3 2.6 3.9 0.6 5.3 2.3 304 0 304 165 0.6 0 0.7 0.7 03/18/2006 07:10:00 3.6 0.5 4.9 2.6 3.5 0.5 4.6 2.3 3.8 0.4 4.9 2.6 304 0 304 165 0.5 0 0.7 0.2 03/18/2006 07:20:00 2.8 0.4 3.8 1.5 2.4 0.5 3.4 1.1 3.2 0.4 4.2 2.3 304 0 304 165 0.6 0 0.7 0.4 03/18/2006 07:30:00 3.8 0.6 5.7 2.6 3.2 0.8 5.7 1.5 4.1 0.6 6.5 3 304 0 304 165 0.7 0 0.9 0.7 03/18/2006 07:40:00 3.3 0.6 4.6 1.9 2.5 0.9 4.6 0.7 3.8 0.6 5.7 2.6 304 0 304 165 0.7 0 0.9 0.7 03/18/2006 07:50:00 3.9 0.5 4.9 2.6 3.5 0.7 4.6 1.5 4.2 0.5 5.3 3 304 0 304 165 0.8 0 0.9 0.7 03/18/2006 08:00:00 3.9 0.5 5.3 2.6 3.2 0.8 4.9 1.5 4.3 0.5 5.7 3 304 0 304 165 0.8 0 0.9 0.9 03/18/2006 08:10:00 3.5 0.5 4.9 2.3 2.9 0.7 4.6 1.1 3.9 0.5 5.7 2.6 304 0 304 165 0.8 0 0.9 0.7 03/18/2006 08:20:00 4 0.9 6.1 2.6 3.4 1.2 6.1 0.7 4.5 0.8 6.8 3 304 0 304 165 0.8 0 0.9 0.7 03/18/2006 08:30:00 4.6 0.5 6.1 3.4 4.1 0.8 5.7 1.5 5 0.5 6.5 3.8 304 0 304 165 0.8 0 0.9 0.7 03/18/2006 08:40:00 4.6 0.6 6.1 3.4 4.2 0.7 6.1 2.3 5 0.6 6.8 3.8 304 0 304 165 0.9 0 1.1 0.9 03/18/2006 08:50:00 4.6 0.5 5.7 3.4 3.9 0.8 5.7 1.9 5 0.4 6.5 4.2 304 0 304 165 0.8 0 0.9 0.9 03/18/2006 09:00:00 4.6 0.5 5.7 3.4 3.6 1 5.7 1.5 5.1 0.5 6.5 3.8 304 0 304 165 0.8 0 0.9 0.7 03/18/2006 09:10:00 4.5 0.5 5.7 3 3.3 1 5.3 1.5 5 0.5 6.5 3.8 304 0 304 165 0.9 0 1.1 0.9 03/18/2006 09:20:00 5.1 1 7.2 3.4 4.4 1.4 7.2 1.5 5.6 1 7.6 3.8 304 0 305 165 0.9 0 1.1 0.9 03/18/2006 09:30:00 4.5 0.5 6.1 3.4 3.8 0.9 6.1 1.5 5.2 0.5 6.8 4.2 305 0 305 165 0.9 0 1.1 0.9 03/18/2006 09:40:00 4.3 0.7 6.1 3 3.8 0.8 5.3 1.9 4.8 0.7 6.5 3.4 305 0 305 165 0.9 0 1.1 0.9 03/18/2006 09:50:00 5.2 0.5 6.8 3.8 4.7 0.9 6.1 1.5 5.9 0.5 8 4.2 309 6 319 165 1 0 1.4 0.9 03/18/2006 10:00:00 4.8 0.4 5.7 3.8 4.7 0.4 5.7 3.4 5.3 0.5 6.8 4.2 324 3 322 165 1.1 0 1.4 0.9 03/18/2006 10:10:00 5 0.5 6.1 3.8 4.5 1 6.1 1.9 5.6 0.4 6.8 4.6 336 5 334 165 1.3 0 1.4 0.9 03/18/2006 10:20:00 4.7 0.4 6.1 3.4 3.8 0.8 5.7 1.9 5.4 0.4 6.8 4.2 346 2 346 165 1.4 0 1.6 1.4 03/18/2006 10:30:00 4.5 0.4 5.7 3.4 3.6 1 5.3 1.5 5.1 0.4 6.1 3.8 345 5 350 165 1.4 0 1.6 1.4 03/18/2006 10:40:00 4.6 0.4 5.7 3.8 2.8 1.1 5.7 1.1 5.2 0.4 6.1 4.2 353 5 345 165 1.4 0 1.6 1.4 03/18/2006 10:50:00 4.2 0.3 4.9 3.4 2.2 0.7 4.2 1.1 4.9 0.4 5.7 4.2 355 3 353 165 1.6 0 1.8 1.4 03/18/2006 11:00:00 4.6 0.6 5.7 3 3.3 1.1 5.7 1.1 5 0.6 6.5 3.4 354 2 355 165 1.7 0 1.8 1.6 03/18/2006 11:10:00 4.5 0.5 5.7 3.4 3 1.3 5.7 0.7 4.8 0.5 6.1 3.8 352 0 352 165 1.7 0 1.8 1.6 03/18/2006 11:20:00 4.5 0.8 6.1 3 3.6 1.4 5.7 0.4 4.9 0.7 6.5 3 351 0 351 165 1.7 0 1.8 1.6 03/18/2006 11:30:00 3.5 0.5 5.3 2.6 2.1 1 5.3 0.4 4 0.6 5.7 2.6 351 0 351 165 1.7 0 1.8 1.6 03/18/2006 11:40:00 3.4 0.5 4.9 2.3 2.2 1 5.3 0.4 3.8 0.6 5.3 2.3 350 2 338 165 1.8 0 1.8 1.6 03/18/2006 11:50:00 3.9 0.3 4.6 3 3.4 0.7 4.9 0.7 4.1 0.4 4.9 2.6 345 4 338 165 1.8 0 1.8 1.6 03/18/2006 12:00:00 3.2 0.5 4.2 1.9 2.2 1 4.2 0.4 3.6 0.6 4.9 1.9 345 10 349 165 1.9 0 1.8 1.8 03/18/2006 12:10:00 3 0.4 3.8 1.9 2 0.8 3.4 0.4 3.1 0.4 4.2 1.9 348 7 336 165 2 0 2.3 1.6 03/18/2006 12:20:00 3.3 0.4 4.2 2.3 1.5 0.6 3 0.4 3.5 0.4 4.9 2.3 357 7 3 165 2.3 0 2.3 2.1 03/18/2006 12:30:00 3.3 0.4 4.6 2.6 3 0.7 4.9 0.7 3.5 0.5 4.9 1.9 343 7 336 165 2.3 0 2.6 2.3 03/18/2006 12:40:00 2.9 0.5 4.2 1.9 2.1 1 4.6 0.4 3.2 0.5 4.6 1.9 350 8 346 165 2.5 0.1 2.8 2.3 03/18/2006 12:50:00 2.7 0.4 3.8 1.9 1.7 0.9 4.2 0.4 3.2 0.4 4.2 2.3 356 8 344 165 2.9 0.1 3.3 2.6 03/18/2006 13:00:00 2.8 0.6 4.6 1.5 2.1 0.9 4.2 0.4 3.2 0.5 4.2 1.9 349 7 356 165 3.4 0.1 3.8 3 03/18/2006 13:10:00 5 0.9 8 3 4.2 1.2 6.8 1.5 4.6 0.9 7.2 2.6 346 12 354 165 3.7 0.1 4 3 03/18/2006 13:20:00 5.3 0.9 7.6 2.3 5.1 1 7.6 1.5 5.1 0.9 7.2 2.6 338 9 338 165 3.5 0.1 3.8 2.8 03/18/2006 13:30:00 5.9 0.7 7.6 4.2 5.7 0.8 7.6 3.8 5.6 0.8 7.2 3.8 337 8 332 165 3.4 0.1 3.5 2.8 03/18/2006 13:40:00 7 1.1 9.5 4.6 6.8 1.3 9.9 4.2 6.8 1.1 9.5 4.2 339 8 355 165 3.1 0 3.5 2.8 03/18/2006 13:50:00 7.6 0.8 10.3 5.7 7 1.5 10.3 3 7.2 0.8 9.1 4.6 342 10 328 165 3.4 0.1 3.8 3 03/18/2006 14:00:00 7.4 0.9 9.5 4.9 7.3 1 9.9 3 6.9 0.9 9.5 4.2 338 7 333 165 3.4 0.2 3.8 2.8 03/18/2006 14:10:00 6.3 1 8.8 4.2 5.9 1 8 3.4 5.9 0.9 8 3.4 337 11 354 165 3.5 0.1 3.8 3.3 03/18/2006 14:20:00 6.6 0.9 9.1 4.6 6 1 9.5 2.6 6.5 0.9 9.9 4.6 340 12 333 165 3.1 0.1 3.5 2.8 03/18/2006 14:30:00 6.1 0.8 8 3.8 6.1 0.8 8 3.8 5.7 0.7 7.2 3.8 321 13 293 165 3.1 0.1 3.5 2.8 03/18/2006 14:40:00 7.8 1.1 10.3 5.3 7.7 1.1 9.9 5.3 6.8 1.1 9.9 4.2 311 13 314 165 2.8 0.3 3.3 2.3 03/18/2006 14:50:00 8.7 0.8 11.5 6.5 8.7 0.8 11.1 6.5 7.2 1.2 10.3 4.2 306 9 295 165 2.2 0.1 2.6 1.8 03/18/2006 15:00:00 9.3 1 11.5 6.8 9.3 1 11.5 6.8 7.3 0.9 9.9 5.3 302 6 300 165 2.2 0 2.6 1.8 03/18/2006 15:10:00 10 0.8 12.2 8 10 0.8 11.8 7.6 7.6 0.9 9.9 5.3 301 5 300 165 2 0.1 2.3 1.4 03/18/2006 15:20:00 9.3 1 12.6 6.8 9.3 1 13 6.5 7.4 1.3 13 4.9 298 8 285 165 2 0.1 2.3 1.4 03/18/2006 15:30:00 8.4 1.1 11.1 5.7 8.3 1.1 10.7 5.3 7.2 1.2 10.3 4.2 306 10 296 165 2.1 0 2.3 1.8 03/18/2006 15:40:00 8.6 1.4 13.3 5.3 8.4 1.5 13.7 4.6 8.3 1.5 13 5.7 328 15 349 165 2.3 0 2.6 2.1 03/18/2006 15:50:00 7.8 1.3 11.1 4.6 7.5 1.4 11.5 4.6 7.4 1.2 11.5 4.9 333 14 333 165 2.4 0.1 2.8 1.8 03/18/2006 16:00:00 9.4 1.7 14.5 3.8 9.1 1.8 14.5 3.8 8.9 1.6 14.1 3.4 333 13 353 165 2.6 0.2 3 1.8 03/18/2006 16:10:00 9.3 1.3 13.3 4.6 9 1.2 12.2 5.3 8.8 1.3 12.6 4.6 325 16 0 165 2.3 0.2 2.6 1.8 03/18/2006 16:20:00 10 1.5 15.3 6.1 10 1.5 15.6 6.5 9.5 1.5 14.9 6.1 324 13 346 165 1.8 0.1 1.8 1.4 03/18/2006 16:30:00 10.7 1.3 13.7 6.5 10.6 1.3 13.7 6.5 9.4 1.4 14.1 5.7 310 7 314 165 1.7 0 1.8 1.1 03/18/2006 16:40:00 11.8 1.3 14.5 8.4 11.7 1.3 14.5 8.4 10.9 1.3 14.5 7.6 314 7 307 165 1.6 0 1.8 1.6 03/18/2006 16:50:00 13.1 1.7 17.6 8.4 13.1 1.7 18.7 8.8 12.9 1.7 16.8 8.4 329 10 341 165 1.5 0 1.6 1.4 03/18/2006 17:00:00 13.4 1.7 16.8 8.4 13.4 1.6 17.2 8.4 13.2 1.7 17.6 8.8 332 8 323 165 1.5 0 1.6 1.4 03/18/2006 17:10:00 12.9 1.7 18.7 8.4 12.8 1.8 18.3 7.2 12.8 1.7 18.3 8.8 334 11 348 165 1.5 0 1.6 1.4 03/18/2006 17:20:00 11.3 1 13.7 7.6 11.2 1 13.7 8 10.7 1.2 13.3 6.1 319 13 309 165 1.2 0 1.4 0.9 03/18/2006 17:30:00 12.1 1.7 16.8 5.7 12 1.7 17.2 6.1 11.2 1.9 16.4 5.7 311 11 317 165 1.1 0 1.4 0.9 03/18/2006 17:40:00 12.4 2.4 17.6 6.5 12.4 2.3 17.6 6.5 11.8 2.6 18.7 6.5 318 12 332 165 1.1 0 1.4 0.9 03/18/2006 17:50:00 11.8 2.1 20.2 7.6 11.8 2.1 20.2 7.6 11.6 2.3 20.2 7.2 330 9 334 165 1.2 0 1.4 0.9 03/18/2006 18:00:00 15.2 2.1 21.4 10.7 15.1 2.2 21.4 9.1 14.9 2.1 21 9.5 333 9 325 165 1.2 0 1.4 1.1 03/18/2006 18:10:00 14.7 2.7 21.8 8.4 14.3 3.1 22.1 6.5 14.5 2.6 21.4 9.5 335 13 326 165 0.9 0.2 1.4 0.7 03/18/2006 18:20:00 15.1 2.1 19.9 9.9 14.4 2.7 21 6.8 15 2.1 20.2 9.1 337 12 339 165 0.4 0.1 0.7 0.2 03/18/2006 18:30:00 16.7 2.8 23.7 10.7 16.3 3.3 24.4 6.8 16.4 3.1 24 10.3 335 11 348 165 0.1 0 0.2 -0.1 03/18/2006 18:40:00 17.2 2.6 23.7 11.8 17.2 2.8 25.2 8.4 17.1 2.7 24.8 11.1 331 11 340 165 0.1 0 0.2 -0.1 03/18/2006 18:50:00 17.5 2.8 25.6 11.8 17.1 2.9 25.6 10.3 17.5 2.8 26.3 12.2 334 10 336 165 -0.2 0 -0.1 -0.3 03/18/2006 19:00:00 18.7 2.3 26 13 18.4 2.6 27.5 9.9 18.5 2.6 26 11.5 332 12 340 165 -0.3 0 -0.1 -0.5 03/18/2006 19:10:00 19.6 2.9 26.8 13.3 19.4 3.3 27.1 11.5 19.5 2.9 27.1 14.1 335 11 321 165 -0.3 0 -0.1 -0.5 03/18/2006 19:20:00 18.9 2.9 27.5 12.2 18.7 3.1 27.5 11.5 18.8 2.9 27.9 14.1 330 12 326 165 -0.3 0 -0.1 -0.5 03/18/2006 19:30:00 18.1 2.5 25.2 13.7 18.2 2.5 26.3 13.3 18 2.6 26 11.5 329 11 330 165 -0.3 0 -0.3 -0.5 03/18/2006 19:40:00 17.5 2.3 22.6 11.5 17 2.9 24.4 8.8 17.4 2.6 26 12.6 334 13 351 165 -0.3 0 -0.1 -0.5 03/18/2006 19:50:00 16.8 2.4 23.3 11.5 16.3 2.6 22.6 9.1 16.4 2.5 23.3 11.1 334 13 348 165 -0.3 0.1 -0.1 -0.5 03/18/2006 20:00:00 17 2 22.9 12.2 17.1 2.1 23.3 12.2 16.9 2.2 22.9 12.2 328 11 332 165 -0.2 0 0.2 -0.3 03/18/2006 20:10:00 15.4 2.2 22.6 9.5 15.1 2.5 22.6 8 14.9 2.3 22.6 8 325 15 345 165 -0.3 0 -0.1 -0.3 03/18/2006 20:20:00 15.4 2 23.3 10.7 15.4 2 23.3 11.1 14.7 1.8 18.7 9.5 319 12 301 165 -0.3 0 -0.1 -0.5 03/18/2006 20:30:00 17.3 1.7 22.1 13 17.2 1.7 22.1 11.8 16.7 1.8 21.4 12.2 319 11 313 165 -0.1 0 0.2 -0.3 03/18/2006 20:40:00 18.1 2.2 24.8 11.8 18.1 2.2 24.8 11.5 16.7 2.4 22.9 10.3 311 11 312 165 0.1 0 0.2 -0.1 03/18/2006 20:50:00 17.8 2.3 26.8 12.2 17.8 2.2 26 11.8 16.7 2.5 26.3 10.7 312 9 316 165 0.1 0.1 0.2 -0.1 03/18/2006 21:00:00 17.9 2.3 24 12.6 17.9 2.3 24.8 11.8 16.7 2.7 24.8 10.3 313 9 324 165 0.2 0 0.4 -0.1 03/18/2006 21:10:00 17.6 2.2 22.1 11.1 17.6 2.2 21.8 11.5 17.1 2.3 21.8 11.5 317 12 302 165 0.2 0 0.4 0.2 03/18/2006 21:20:00 16.9 2.2 24.4 12.2 16.9 2.2 24 11.8 16.4 2.5 25.2 11.8 317 11 314 165 0.2 0 0.4 -0.1 03/18/2006 21:30:00 16.8 2.2 22.6 10.7 16.7 2.2 22.1 10.7 15.6 2.1 22.9 11.1 315 12 305 165 0.2 0 0.2 0.2 03/18/2006 21:40:00 17.4 2.1 21.8 10.7 17.3 2.1 22.1 10.3 16.5 2 22.9 10.3 314 10 307 165 0.1 0 0.2 -0.1 03/18/2006 21:50:00 16.8 2.4 22.6 10.3 16.7 2.4 22.1 9.5 15.9 2.6 21.8 9.1 316 10 302 165 0.1 0 0.2 -0.1 03/18/2006 22:00:00 17.2 2 23.7 12.6 17.1 2 23.7 11.8 16.3 2.1 22.9 10.7 315 12 304 165 0.1 0 0.2 -0.1 03/18/2006 22:10:00 17 2.2 25.2 11.5 16.9 2.2 24.8 11.8 16.2 2.3 22.9 9.5 320 14 295 165 -0.1 0 0.2 -0.3 03/18/2006 22:20:00 16.3 1.8 21.8 11.5 16.2 1.8 21 11.5 15.9 2 21.4 10.7 321 11 325 165 -0.3 0 -0.1 -0.3 03/18/2006 22:30:00 16.8 2.2 22.9 11.8 16.7 2.2 23.3 11.8 15.6 2.3 22.1 10.3 313 10 307 165 -0.3 0 -0.3 -0.5 03/18/2006 22:40:00 18.1 2.5 23.3 12.2 18 2.5 23.3 11.5 16.9 2.6 24.4 10.3 313 12 322 165 -0.3 0 -0.3 -0.5 03/18/2006 22:50:00 16.4 2.6 24 9.5 16.4 2.6 24 9.5 15.5 2.9 24.8 9.1 318 13 330 165 -0.4 0 -0.3 -0.5 03/18/2006 23:00:00 16.3 2.4 22.9 9.9 16.1 2.4 23.3 9.5 15.4 2.3 22.6 10.3 319 15 305 165 -0.5 0 -0.3 -0.5 03/18/2006 23:10:00 17.3 2.1 21.8 11.8 17.1 2 21.4 11.5 15.8 2 19.9 9.1 312 10 313 165 -0.6 0 -0.5 -0.8 03/18/2006 23:20:00 16.1 2.6 22.6 8 15.9 2.6 22.6 8.8 15.6 2.5 22.6 8 322 15 290 165 -0.4 0.1 -0.3 -0.8 03/18/2006 23:30:00 16.6 2.3 22.6 9.5 16.5 2.2 22.1 9.5 15.4 2.3 22.1 10.3 315 12 312 165 -0.4 0 -0.3 -0.8 03/18/2006 23:40:00 16.7 2.3 24 10.3 16.4 2.4 23.3 9.9 15.7 2.1 22.6 9.5 328 15 307 165 -0.5 0 -0.5 -0.8 03/18/2006 23:50:00 16.7 2.3 23.3 9.9 16.6 2.3 23.3 9.5 15.7 2.4 22.1 9.9 314 13 307 165 -0.6 0 -0.5 -0.8 03/19/2006 00:00:00 18.1 2.2 25.6 12.6 18.1 2.2 25.2 12.2 17.1 2.5 25.2 11.5 316 12 299 165 -0.7 0 -0.5 -1 03/19/2006 00:10:00 17.7 2.4 24.8 12.6 17.6 2.4 24.8 12.6 15.9 2.4 22.1 10.3 309 9 300 165 -0.8 0 -0.5 -0.8 03/19/2006 00:20:00 18.4 2.4 26 12.6 18.3 2.4 26.3 12.2 16.8 2.4 22.6 11.1 309 9 312 165 -0.8 0 -0.8 -0.8 03/19/2006 00:30:00 19.3 2.3 24.8 13.7 19.2 2.3 24.8 13.7 17.6 2.9 24.8 9.9 309 11 313 165 -0.8 0 -0.5 -0.8 03/19/2006 00:40:00 18.7 2.8 29.1 12.2 18.7 2.8 28.7 11.8 18.1 2.8 28.3 11.5 316 10 313 165 -0.8 0 -0.5 -0.8 03/19/2006 00:50:00 17.4 2.2 25.2 11.8 17.4 2.2 24.8 11.5 17 2.1 23.3 12.2 317 10 300 165 -0.9 0 -0.8 -1 03/19/2006 01:00:00 17.1 2.2 23.7 13 17.1 2.2 23.7 12.6 16.8 2.2 24 12.6 321 9 316 165 -0.9 0 -0.8 -1 03/19/2006 01:10:00 17.6 2.4 26.3 13 17.5 2.4 26 12.2 17 2.5 24.4 11.5 317 9 297 165 -0.9 0 -0.8 -1 03/19/2006 01:20:00 17.6 2.4 24 11.8 17.6 2.4 23.7 11.8 17.3 2.4 23.7 10.7 319 8 308 165 -0.9 0 -0.8 -1 03/19/2006 01:30:00 19.3 2 24 14.1 19.3 2 24 14.1 19.2 2.2 24 14.1 322 9 322 165 -0.8 0 -0.5 -0.8 03/19/2006 01:40:00 17.8 2.2 24 11.8 17.4 2.5 23.7 11.5 17.3 2.4 24 11.5 328 15 300 165 -0.8 0.1 -0.5 -1 03/19/2006 01:50:00 18.5 2.4 25.6 11.8 18.4 2.4 25.6 11.8 17.8 2.7 25.6 11.5 317 10 314 165 -0.9 0 -0.8 -1 03/19/2006 02:00:00 17.4 2.8 25.2 11.8 17.4 2.8 25.2 10.7 16.6 3.1 26.3 11.1 321 13 318 165 -0.9 0 -0.8 -1 03/19/2006 02:10:00 16.8 2.2 23.3 12.2 16.5 2.3 23.7 11.1 16.3 2.3 22.9 10.7 329 15 301 165 -0.9 0 -0.8 -1.2 03/19/2006 02:20:00 17.7 2.6 24.8 11.8 16.8 2.6 23.3 11.1 17.6 2.7 25.2 10.7 337 14 347 165 -1 0 -0.8 -1.2 03/19/2006 02:30:00 20.1 2.6 26 13 19.9 2.8 26 12.6 19.9 2.8 27.9 12.6 338 9 348 165 -1 0 -0.8 -1.2 03/19/2006 02:40:00 15.7 2 22.9 10.3 15.6 2 22.6 10.3 15 1.9 21 9.9 320 12 303 165 -0.9 0 -0.8 -1.2 03/19/2006 02:50:00 16 2.3 21.4 10.3 15.4 2.3 22.1 10.7 15.4 2.6 22.1 9.5 330 16 312 165 -0.9 0 -0.8 -1 03/19/2006 03:00:00 15.7 1.8 20.2 9.9 15.6 1.7 19.9 9.9 15.1 2 20.6 9.9 324 12 315 165 -1 0 -0.8 -1.2 03/19/2006 03:10:00 17.4 2.1 24.8 12.2 17.4 2.2 25.6 11.1 16.6 2.1 24.8 12.2 318 9 313 165 -0.9 0 -0.8 -1.2 03/19/2006 03:20:00 16 1.4 19.9 12.2 15.9 1.4 19.5 12.2 15.3 1.5 19.1 10.3 319 8 308 165 -1 0 -0.8 -1.2 03/19/2006 03:30:00 15.2 1.5 19.5 11.5 15.1 1.5 19.1 11.1 15 1.5 18.3 10.7 324 9 326 165 -1 0 -0.8 -1.2 03/19/2006 03:40:00 16.7 2.2 21.8 10.3 16.6 2.2 22.1 10.3 16.2 2.4 21.8 10.3 319 10 315 165 -0.9 0 -0.8 -1 03/19/2006 03:50:00 16.2 1.5 21.8 9.5 16.2 1.5 21.8 9.5 15.7 1.7 21.4 10.7 320 9 314 165 -1 0 -0.8 -1.2 03/19/2006 04:00:00 15.6 1.9 21 11.1 15.5 1.9 21 11.1 14.4 2.1 19.9 8.8 314 10 307 165 -1 0 -0.8 -1.2 03/19/2006 04:10:00 15.5 1.7 20.2 11.1 15.4 1.7 20.2 10.7 14.6 1.7 19.5 9.9 317 11 309 165 -1 0 -0.8 -1.2 03/19/2006 04:20:00 14.7 1.7 19.1 9.5 14.6 1.7 19.5 10.7 13.9 1.8 21.4 9.1 318 10 304 165 -1 0 -0.8 -1.2 03/19/2006 04:30:00 15.6 1.9 22.1 10.7 15.5 1.9 22.1 10.7 14.4 1.9 22.1 8.4 315 9 321 165 -1 0 -0.8 -1.2 03/19/2006 04:40:00 16.2 1.5 20.2 12.6 16.2 1.5 20.2 12.2 15.1 1.6 19.1 10.7 313 7 319 165 -1 0.1 -0.8 -1.4 03/19/2006 04:50:00 17.8 1.3 21 14.1 17.7 1.3 20.6 14.1 17 1.3 20.6 13 314 7 320 165 -1.2 0 -1 -1.4 03/19/2006 05:00:00 15.8 1.7 21.4 11.5 15.6 1.8 21.8 11.8 15.4 1.8 20.2 11.1 322 13 311 165 -1.2 0 -1 -1.2 03/19/2006 05:10:00 13.9 1.3 17.9 9.5 13.7 1.5 18.7 9.5 13.4 1.5 17.6 9.5 330 11 342 165 -1 0 -0.8 -1.2 03/19/2006 05:20:00 14.8 1.2 17.9 11.1 14.7 1.2 17.9 11.8 13.9 1.3 16.8 9.1 315 7 313 165 -1 0 -0.8 -1.2 03/19/2006 05:30:00 16.2 1.3 22.6 12.6 16.1 1.3 22.1 12.2 15.7 1.5 22.6 11.8 319 9 320 165 -1 0 -0.8 -1.4 03/19/2006 05:40:00 16.9 1.6 21.4 12.2 16.8 1.7 21 10.7 16.5 1.6 21.4 13 326 12 318 165 -0.9 0 -0.5 -1.2 03/19/2006 05:50:00 14.4 1.4 17.9 10.3 14.3 1.5 18.7 9.9 13.6 1.5 17.6 8 319 10 310 165 -0.9 0 -0.8 -1.2 03/19/2006 06:00:00 14.6 1.5 19.1 11.1 14.5 1.5 19.1 10.7 13.7 1.6 18.7 9.5 316 8 316 165 -1 0 -0.8 -1.2 03/19/2006 06:10:00 14.3 2.5 19.9 9.1 14.2 2.5 19.9 9.1 13.5 2.6 19.9 7.2 318 11 309 165 -0.9 0 -0.8 -1.2 03/19/2006 06:20:00 12.6 1.6 19.1 8.8 12.5 1.7 18.7 8.4 12 1.5 17.6 8.4 322 12 307 165 -1 0 -0.8 -1.2 03/19/2006 06:30:00 14.9 1.7 18.7 11.1 14.8 1.7 18.7 10.7 13.8 1.9 18.7 9.5 312 6 316 165 -1 0 -0.8 -1.2 03/19/2006 06:40:00 16.8 1.3 19.9 13.3 16.7 1.3 19.9 13 16.1 1.5 19.9 12.2 315 5 312 165 -1.2 0 -1 -1.4 03/19/2006 06:50:00 15.5 1.5 19.9 11.1 15.4 1.5 19.9 10.7 15 1.7 19.9 9.1 317 7 313 165 -1.3 0 -1.2 -1.4 03/19/2006 07:00:00 16.3 1.3 19.9 12.2 16.2 1.3 19.9 12.2 15.6 1.5 20.2 11.8 316 6 317 165 -1.3 0 -1.2 -1.4 03/19/2006 07:10:00 18.2 2 23.7 14.1 18.1 2 23.7 13.7 17.9 2.3 23.7 12.2 321 7 307 165 -1.2 0 -1 -1.4 03/19/2006 07:20:00 10.3 4.5 19.9 1.5 10.2 4.5 19.9 2.3 8.9 5.1 19.9 0.7 326 23 338 165 -1 0 -0.8 -1.2 03/19/2006 07:30:00 4.6 2.5 11.8 0.4 4.4 2.6 11.1 0.4 3.3 2 8.8 0.4 323 64 291 165 -1 0.1 -0.8 -1.2 03/19/2006 07:40:00 9.4 2.1 15.3 4.9 9.4 2.1 15.3 4.9 8.4 1.9 13.3 4.2 312 12 303 165 -0.6 0.2 -0.3 -1 03/19/2006 07:50:00 7.8 1.7 10.7 3.4 7.7 1.7 11.1 3.4 6.7 1.7 10.7 2.6 307 9 290 165 -0.4 0 -0.3 -0.5 03/19/2006 08:00:00 7.6 1 9.9 4.9 7.6 0.9 9.9 4.9 6.3 1 9.5 3.8 303 9 308 165 -0.5 0 -0.3 -0.5 03/19/2006 08:10:00 7.8 1.2 10.7 4.9 7.8 1.2 11.1 4.9 6.1 1.1 10.3 3.8 298 7 286 165 -0.7 0.1 -0.5 -0.8 03/19/2006 08:20:00 9.5 1.1 12.2 7.2 9.4 1.1 12.2 6.5 7.1 1.1 10.3 4.9 299 6 295 165 -0.8 0 -0.5 -1 03/19/2006 08:30:00 9.7 1 12.6 6.8 9.6 0.9 12.2 6.8 7.2 1 10.7 4.9 299 6 295 165 -0.8 0 -0.5 -1 03/19/2006 08:40:00 9.8 0.6 11.5 8 9.8 0.6 11.5 8.4 8.1 1.1 10.7 5.3 305 5 304 165 -0.8 0 -0.5 -1 03/19/2006 08:50:00 10.3 0.7 11.8 8.4 10.3 0.7 11.8 8.4 9.8 0.9 11.8 7.2 310 3 310 165 -0.7 0 -0.5 -0.8 03/19/2006 09:00:00 12 0.5 13 10.7 11.9 0.5 13 10.7 11.7 0.8 13 9.1 312 3 320 165 -0.6 0 -0.5 -0.8 03/19/2006 09:10:00 11.1 1 13 9.1 11 1 13 8.8 10.9 1 13 8.4 315 3 312 165 -0.3 0.1 -0.1 -0.8 03/19/2006 09:20:00 6.7 1.3 9.5 4.6 6.7 1.2 9.1 4.6 5.9 1.6 9.1 2.6 309 5 309 165 0.4 0.4 1.1 -0.3 03/19/2006 09:30:00 4.3 0.7 6.1 1.9 4.3 0.7 6.1 2.3 3.5 1.1 6.1 0.4 310 11 302 165 1.6 0.1 1.8 1.1 03/19/2006 09:40:00 5.2 0.8 6.8 3 5.1 0.8 6.8 3 4.7 0.9 6.1 2.6 311 6 306 165 1.5 0.2 1.8 0.9 03/19/2006 09:50:00 5.3 0.7 7.6 3.8 5.2 0.7 7.2 3.8 4.6 0.8 6.5 2.6 304 8 302 165 0.7 0.2 1.1 0.2 03/19/2006 10:00:00 5.7 0.6 7.2 4.2 5.6 0.6 7.2 4.2 4.4 0.6 6.1 3 298 7 302 165 0.7 0.1 0.9 0.2 03/19/2006 10:10:00 4.9 0.6 6.1 3 4.8 0.6 6.1 3 4 0.6 6.1 2.6 296 9 295 165 1.1 0.1 1.4 0.7 03/19/2006 10:20:00 4.1 0.8 5.7 2.3 4.1 0.8 5.7 1.9 3.8 0.8 5.7 1.9 284 8 277 165 1.2 0 1.6 0.9 03/19/2006 10:30:00 2.3 0.9 3.8 0.4 2.2 0.9 3.8 0.4 2 0.8 3.8 0.4 286 18 288 165 1.8 0.3 3 1.4 03/19/2006 10:40:00 1 0.5 2.6 0.4 1.1 0.6 3 0.4 1.1 0.5 3 0.4 263 22 254 165 3 0.4 3.8 2.3 03/19/2006 10:50:00 1.9 0.5 3 1.1 1.6 0.5 2.6 0.7 2 0.5 3.4 0.7 235 13 238 165 2.4 0.1 3 2.3 03/19/2006 11:00:00 1.7 0.6 3 0.4 1.8 0.6 3 0.4 1.9 0.6 3 0.4 254 7 245 165 1.7 0.2 2.6 1.4 03/19/2006 11:10:00 2.2 0.6 4.2 0.7 2.2 0.7 4.2 0.7 2.2 0.6 3.8 0.7 216 12 211 165 2.7 0.2 3 1.8 03/19/2006 11:20:00 4.9 0.6 6.1 2.6 4.7 0.6 6.1 2.6 5 0.6 6.1 3 173 10 172 165 1.6 0.4 2.8 1.1 03/19/2006 11:30:00 5.6 0.5 6.8 4.2 5.3 0.4 6.5 4.2 5.7 0.5 6.8 4.2 166 4 165 165 1.2 0.1 1.6 0.9 03/19/2006 11:40:00 5.5 0.4 6.8 4.6 5.2 0.4 6.5 4.2 5.6 0.5 6.8 4.6 162 5 159 165 1.4 0 1.6 1.4 03/19/2006 11:50:00 4.5 0.5 5.7 3 4.4 0.5 5.7 3 4.5 0.5 5.7 3 158 11 172 165 1.4 0.1 1.8 1.4 03/19/2006 12:00:00 4.3 0.5 5.3 3.4 4.2 0.5 5.3 3.4 4.4 0.5 6.1 3.4 152 6 162 165 1.1 0 1.8 0.9 03/19/2006 12:10:00 4.1 0.4 4.9 3.4 3.9 0.4 4.9 3.4 4.1 0.4 4.9 3.4 150 6 149 165 1.1 0 1.4 0.9 03/19/2006 12:20:00 3.5 0.4 4.6 2.3 3.4 0.4 4.2 1.9 3.5 0.4 4.6 2.3 153 7 151 165 1.3 0 1.6 0.9 03/19/2006 12:30:00 3.6 0.4 4.9 2.6 3.5 0.4 4.6 2.6 3.7 0.4 4.6 2.6 153 6 155 165 1.4 0.1 1.6 0.9 03/19/2006 12:40:00 3.8 0.4 4.6 2.6 3.7 0.4 4.9 2.6 3.9 0.3 4.6 3 151 6 146 165 1.1 0 1.4 0.7 03/19/2006 12:50:00 4.1 0.4 4.9 3 3.9 0.4 4.9 3 3.9 0.5 5.3 2.6 143 8 163 165 1.2 0.2 1.6 0.7 03/19/2006 13:00:00 4.9 0.6 6.8 3.8 4.7 0.5 6.5 3.8 4.9 0.5 6.8 3.8 155 5 157 165 1.2 0.1 1.6 0.7 03/19/2006 13:10:00 6.4 0.4 7.2 5.7 6.2 0.4 7.2 5.3 6.6 0.4 7.6 5.3 150 4 151 165 0.9 0.2 1.8 0.2 03/19/2006 13:20:00 5.9 0.4 6.8 4.6 5.8 0.4 6.8 4.6 6 0.4 6.8 4.9 149 3 148 165 0.7 0.2 1.1 0.2 03/19/2006 13:30:00 5.6 0.5 6.5 4.6 5.5 0.4 6.5 4.2 5.7 0.5 6.8 4.6 149 4 148 165 0.7 0.2 1.4 0.2 03/19/2006 13:40:00 5.5 0.4 6.5 4.6 5.5 0.4 6.5 4.2 5.6 0.5 6.8 4.6 143 5 145 165 1.2 0.2 1.6 0.7 03/19/2006 13:50:00 5 0.5 6.5 3.8 5 0.5 6.5 3.8 4.9 0.5 6.5 3.4 138 6 138 165 1.5 0 1.6 1.1 03/19/2006 14:00:00 4.5 0.5 6.1 3 4.5 0.5 5.7 3 4.6 0.5 5.7 3.4 140 9 136 165 1.6 0.1 1.8 0.9 03/19/2006 14:10:00 4.7 0.5 6.1 3.8 4.6 0.5 6.1 3.4 4.8 0.5 6.5 3.4 140 7 130 165 2 0.1 2.3 1.4 03/19/2006 14:20:00 4.8 0.4 6.1 3.4 4.7 0.4 6.1 3.4 4.8 0.4 6.1 3.8 145 6 148 165 1.7 0.1 2.1 1.4 03/19/2006 14:30:00 5.1 0.3 5.7 4.2 5 0.3 5.7 4.2 5.2 0.3 6.1 4.2 144 4 139 165 1.4 0.1 1.8 0.9 03/19/2006 14:40:00 5.5 0.4 6.5 4.2 5.4 0.4 6.5 4.2 5.5 0.4 6.5 4.6 148 4 147 165 1.4 0 1.6 1.4 03/19/2006 14:50:00 5 0.4 5.7 4.2 4.9 0.5 6.1 4.2 5.1 0.5 6.1 3.8 152 3 145 165 1.5 0.1 1.8 1.4 03/19/2006 15:00:00 4.4 0.4 5.3 3.4 4.4 0.4 5.3 3.4 4.5 0.4 5.7 3.8 153 5 161 165 1.9 0 2.1 1.8 03/19/2006 15:10:00 4.2 0.3 4.9 3.4 4.2 0.3 4.9 3.4 4.3 0.3 4.9 3.4 150 6 148 165 1.9 0.2 2.3 1.4 03/19/2006 15:20:00 3.9 0.3 4.9 3 3.8 0.4 5.3 2.6 3.9 0.4 4.9 3 146 6 130 165 1.7 0 1.8 1.4 03/19/2006 15:30:00 3.9 0.3 4.6 3 3.9 0.3 4.6 3 4 0.4 4.9 3 151 7 150 165 1.8 0 1.8 1.6 03/19/2006 15:40:00 3.9 0.3 4.6 3 3.8 0.3 4.6 3 4 0.3 4.6 3 155 4 157 165 2 0 2.3 1.8 03/19/2006 15:50:00 3.9 0.3 4.6 3.4 3.8 0.3 4.9 3.4 4 0.3 4.9 3.4 151 5 148 165 2.1 0 2.3 1.8 03/19/2006 16:00:00 3.9 0.4 4.9 2.3 3.8 0.4 4.6 2.6 4 0.4 4.9 3 148 7 159 165 2.6 0 2.8 2.3 03/19/2006 16:10:00 3.9 0.4 4.9 3 3.9 0.4 4.9 3 4 0.4 4.9 3 145 11 145 165 2.9 0 3 2.8 03/19/2006 16:20:00 3.9 0.4 4.9 3 3.8 0.4 4.9 2.6 3.9 0.4 4.9 2.6 152 7 156 165 2.9 0 3.3 2.8 03/19/2006 16:30:00 3.8 0.5 4.9 2.3 3.7 0.5 4.9 2.3 3.8 0.5 5.3 2.3 143 11 157 165 2.9 0 3.3 2.8 03/19/2006 16:40:00 3.3 0.3 4.2 2.6 3.2 0.3 4.2 2.3 3.3 0.3 4.2 2.6 138 8 115 165 2.9 0 3 2.8 03/19/2006 16:50:00 2.8 0.5 4.2 1.5 2.7 0.5 4.2 1.5 2.8 0.6 4.6 1.5 145 8 156 165 3.1 0 3.3 2.8 03/19/2006 17:00:00 2.5 0.4 3.8 1.9 2.5 0.4 3.8 1.9 2.5 0.4 3.8 1.5 139 15 143 165 2.5 0.1 3 2.1 03/19/2006 17:10:00 1.8 0.3 2.6 0.7 1.8 0.3 2.6 0.7 1.8 0.4 2.6 0.7 114 11 101 165 3.1 0.1 3.5 2.6 03/19/2006 17:20:00 1 0.5 2.3 0.4 1 0.5 2.3 0.4 0.9 0.5 2.3 0.4 112 7 139 165 2.6 0.2 3.3 1.8 03/19/2006 17:30:00 1.2 0.4 1.9 0.4 1.1 0.4 1.9 0.4 1.4 0.5 2.3 0.4 30 26 12 165 2.7 0.2 3 2.3 03/19/2006 17:40:00 1.7 0.3 2.3 0.7 1.5 0.3 2.3 0.7 1.9 0.3 2.6 1.1 21 11 7 165 3 0.4 3.8 2.1 03/19/2006 17:50:00 2 0.4 3 1.1 1.6 0.4 3 0.4 2.1 0.4 3 1.1 350 6 341 165 3.4 0.3 4 2.6 03/19/2006 18:00:00 2.8 0.4 3.4 1.9 2.4 0.6 3.4 0.7 2.8 0.4 3.8 1.9 347 6 347 165 3 0.3 3.8 2.6 03/19/2006 18:10:00 2 0.5 3 0.7 1.6 0.5 2.6 0.4 2 0.5 3 1.1 0 15 358 165 4.1 0.2 4.5 3.5 03/19/2006 18:20:00 1.6 0.4 2.6 0.4 1.2 0.5 2.6 0.4 1.8 0.4 2.6 1.1 352 10 350 165 4.1 0.1 4.5 3.5 03/19/2006 18:30:00 0.9 0.3 1.9 0.4 1 0.4 2.3 0.4 1.3 0.2 1.9 0.7 345 19 317 165 4 0.1 4.3 3.5 03/19/2006 18:40:00 1.6 0.2 1.9 1.1 1.9 0.2 2.3 1.1 1.5 0.3 1.9 0.7 305 4 308 165 3.4 0.4 4.5 2.3 03/19/2006 18:50:00 0.9 0.5 1.9 0.4 0.9 0.5 1.9 0.4 0.8 0.3 1.9 0.4 283 14 302 165 2.4 0.3 2.8 1.6 03/19/2006 19:00:00 0.4 0.2 1.5 0.4 0.4 0.2 1.1 0.4 0.5 0.2 1.1 0.4 260 43 153 165 2.2 0 2.6 1.8 03/19/2006 19:10:00 0.4 0.2 1.5 0.4 0.4 0.2 1.5 0.4 0.6 0.2 1.1 0.4 153 0 153 165 1.9 0.2 2.3 1.4 03/19/2006 19:20:00 0.4 0.1 0.7 0.4 0.4 0.1 0.7 0.4 0.4 0.1 1.1 0.4 186 43 153 165 1.7 0.1 1.8 1.4 03/19/2006 19:30:00 1.7 0.7 3 0.4 1.7 0.8 3 0.4 1.6 0.8 2.6 0.4 212 15 204 165 1.8 0 2.1 1.6 03/19/2006 19:40:00 2.4 0.2 3 1.9 2.5 0.2 3 1.9 2.6 0.3 3 1.5 206 1 206 165 2 0 2.3 1.8 03/19/2006 19:50:00 2.2 0.5 3 0.4 2.3 0.5 3 0.7 2.5 0.4 3.4 1.1 216 9 211 165 1.9 0 2.1 1.8 03/19/2006 20:00:00 1.3 0.4 2.6 0.4 1.5 0.4 2.6 0.4 1.7 0.3 2.6 1.1 224 15 270 165 1.8 0 2.3 1.6 03/19/2006 20:10:00 1.2 0.6 3 0.4 1.3 0.6 3 0.4 1.2 0.3 2.6 0.4 282 28 310 165 1.8 0.1 2.3 1.4 03/19/2006 20:20:00 3.5 0.7 5.7 1.9 3.5 0.7 5.7 1.9 3.2 0.7 5.3 1.5 316 6 319 165 1.9 0.1 2.3 1.4 03/19/2006 20:30:00 2.9 1 5.3 1.1 3 0.9 5.3 1.1 2.6 0.9 4.9 1.1 306 9 322 165 1.8 0.1 2.1 1.6 03/19/2006 20:40:00 1.5 0.9 3.4 0.4 1.6 1 3.4 0.4 1.5 0.7 3.4 0.4 316 24 306 165 2.1 0 2.3 1.8 03/19/2006 20:50:00 0.7 0.5 3.4 0.4 0.9 0.7 3 0.4 0.8 0.6 2.3 0.4 295 38 286 165 1.9 0 2.3 1.8 03/19/2006 21:00:00 0.6 0.4 1.9 0.4 0.7 0.5 2.3 0.4 0.7 0.5 1.9 0.4 300 72 252 165 2 0 2.3 1.8 03/19/2006 21:10:00 0.4 0.2 1.5 0.4 0.5 0.3 1.9 0.4 0.6 0.4 1.9 0.4 235 49 128 165 2 0.2 2.3 1.6 03/19/2006 21:20:00 0.7 0.5 1.5 0.4 0.7 0.4 1.5 0.4 1 0.5 1.9 0.4 130 6 128 165 1.5 0.1 1.8 1.4 03/19/2006 21:30:00 1.6 1 3.4 0.4 1.8 1 3.4 0.4 1.5 1 3.4 0.4 325 90 288 165 1.7 0.2 2.1 1.4 03/19/2006 21:40:00 2.3 0.6 3.4 0.4 2.5 0.5 3.4 1.1 2.4 0.5 3.4 1.1 281 6 290 165 2 0 2.3 1.8 03/19/2006 21:50:00 0.7 0.5 2.6 0.4 1.1 0.7 3 0.4 1.2 0.6 2.6 0.4 224 47 271 165 1.9 0 1.8 1.6 03/19/2006 22:00:00 0.4 0.2 1.5 0.4 0.5 0.3 1.9 0.4 0.6 0.3 1.5 0.4 186 66 266 165 1.8 0 1.8 1.6 03/19/2006 22:10:00 0.5 0.3 1.5 0.4 0.7 0.4 1.9 0.4 0.8 0.4 1.9 0.4 264 21 249 165 1.9 0 2.1 1.8 03/19/2006 22:20:00 0.8 0.4 1.9 0.4 0.9 0.5 2.3 0.4 0.8 0.5 2.6 0.4 258 11 246 165 1.9 0 2.1 1.6 03/19/2006 22:30:00 0.9 0.5 1.9 0.4 1.1 0.5 2.3 0.4 1.1 0.6 2.6 0.4 262 13 259 165 1.8 0 1.8 1.6 03/19/2006 22:40:00 1.7 0.5 2.6 0.4 1.8 0.4 2.6 0.7 1.7 0.3 2.3 0.7 288 9 291 165 1.9 0 2.1 1.8 03/19/2006 22:50:00 1.7 0.3 2.6 0.7 1.8 0.4 2.6 0.7 1.8 0.4 2.6 0.7 288 5 282 165 2.1 0 2.3 1.8 03/19/2006 23:00:00 1.2 0.5 2.3 0.4 1.3 0.5 2.3 0.4 1.4 0.4 2.6 0.4 289 12 294 165 2.3 0 2.6 1.8 03/19/2006 23:10:00 1.3 0.4 2.3 0.4 1.5 0.3 2.6 0.4 1.7 0.4 2.6 0.7 278 9 278 165 2.3 0 2.6 2.3 03/19/2006 23:20:00 1.5 0.5 2.6 0.4 1.7 0.5 2.6 0.4 1.7 0.4 2.6 0.7 301 8 304 165 2.2 0 2.6 2.1 03/19/2006 23:30:00 1.5 0.3 2.3 0.7 1.6 0.3 2.3 1.1 1.5 0.3 2.3 0.7 296 9 291 165 2.1 0 2.3 1.8 03/19/2006 23:40:00 1 0.5 1.9 0.4 1.1 0.6 1.9 0.4 1.4 0.5 2.3 0.7 307 4 296 165 2.1 0 2.3 1.8 03/19/2006 23:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.5 0.3 1.1 0.4 275 47 165 165 2 0 2.3 1.8 03/20/2006 00:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.8 0.2 1.5 0.4 178 16 165 165 1.9 0 2.1 1.8 03/20/2006 00:10:00 0.4 0.1 1.1 0.4 0.4 0.1 1.1 0.4 0.9 0.3 1.5 0.4 259 24 288 165 2.1 0 2.3 1.8 03/20/2006 00:20:00 0.4 0.2 1.1 0.4 0.4 0.2 1.1 0.4 1 0.3 1.5 0.4 289 4 300 165 1.9 0 1.8 1.8 03/20/2006 00:30:00 1.2 0.2 1.5 0.7 1.4 0.2 1.9 0.7 1.9 0.2 2.3 1.1 317 9 310 165 1.7 0 1.8 1.6 03/20/2006 00:40:00 1.5 0.3 2.3 0.7 0.9 0.4 1.9 0.4 1.9 0.3 2.3 1.1 357 10 356 165 1.4 0 1.6 1.4 03/20/2006 00:50:00 1.7 0.3 2.3 1.1 1.6 0.3 2.3 1.1 1.8 0.3 2.3 1.1 40 13 54 165 1.7 0.2 1.8 1.4 03/20/2006 01:00:00 1.9 0.3 2.6 1.5 1.9 0.4 2.6 1.1 2.2 0.3 2.6 1.9 53 0 54 165 1.9 0 2.3 1.8 03/20/2006 01:10:00 1.5 0.4 2.3 0.7 1.4 0.4 2.3 0.4 1.9 0.3 2.6 1.1 42 5 43 165 1.8 0 1.8 1.6 03/20/2006 01:20:00 0.5 0.2 1.5 0.4 0.5 0.2 1.1 0.4 1.1 0.2 1.5 0.4 49 13 65 165 1.7 0 1.8 1.6 03/20/2006 01:30:00 1 0.4 1.5 0.4 0.8 0.3 1.5 0.4 1.6 0.3 2.3 0.7 30 16 25 165 1.6 0 1.6 1.6 03/20/2006 01:40:00 0.6 0.3 1.5 0.4 0.4 0.2 1.1 0.4 1 0.5 1.9 0.4 13 0 13 165 1.6 0 1.6 1.4 03/20/2006 01:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 13 0 165 165 1.4 0 1.6 1.4 03/20/2006 02:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0.1 0.7 0.4 13 0 165 165 1.5 0 1.8 1.4 03/20/2006 02:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 19 24 165 165 1.8 0 1.8 1.6 03/20/2006 02:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.7 0.2 1.1 0.4 114 0 165 165 1.8 0 1.8 1.6 03/20/2006 02:30:00 0.5 0.3 1.1 0.4 0.4 0 0.4 0.4 1.1 0.3 1.5 0.7 144 19 161 165 1.9 0 2.1 1.8 03/20/2006 02:40:00 1.5 0.4 2.3 0.7 1.1 0.6 2.3 0.4 1.8 0.4 2.6 1.1 163 1 166 165 1.9 0 1.8 1.8 03/20/2006 02:50:00 1.9 0.2 2.3 1.5 1.8 0.2 2.3 1.5 2.1 0.2 2.6 1.5 162 2 162 165 1.7 0 1.8 1.4 03/20/2006 03:00:00 1.6 0.3 2.3 1.1 1.5 0.3 2.3 1.1 1.9 0.3 2.6 1.1 160 2 162 165 1.5 0 1.6 1.4 03/20/2006 03:10:00 2 0.2 2.3 1.5 1.9 0.2 2.3 1.5 2.3 0.2 2.6 1.9 154 4 160 165 1.6 0 1.8 1.4 03/20/2006 03:20:00 1.7 0.3 2.3 0.7 1.6 0.3 2.3 0.4 2.1 0.3 2.6 1.1 151 5 156 165 1.7 0 1.8 1.6 03/20/2006 03:30:00 1.4 0.3 1.9 0.4 1.4 0.3 1.9 0.4 1.9 0.2 2.3 1.1 152 4 150 165 1.7 0 1.8 1.6 03/20/2006 03:40:00 1.6 0.3 2.3 0.7 1.5 0.3 2.3 0.7 2 0.3 2.6 1.1 141 6 144 165 1.6 0 1.6 1.4 03/20/2006 03:50:00 1.9 0.2 2.6 1.5 1.9 0.3 2.6 1.5 2.3 0.2 2.6 1.9 140 2 140 165 1.5 0 1.6 1.4 03/20/2006 04:00:00 1.2 0.3 1.9 0.4 1 0.4 1.9 0.4 1.6 0.3 2.3 1.1 145 8 144 165 1.4 0 1.6 1.4 03/20/2006 04:10:00 1 0.3 1.5 0.4 0.7 0.3 1.5 0.4 1.5 0.2 1.9 1.1 162 5 158 165 1.4 0 1.6 1.4 03/20/2006 04:20:00 0.8 0.4 1.9 0.4 0.6 0.4 1.5 0.4 1.1 0.5 1.9 0.4 166 2 166 165 1.5 0 1.6 1.4 03/20/2006 04:30:00 0.8 0.3 1.5 0.4 0.5 0.2 1.1 0.4 1.3 0.3 1.9 0.4 186 6 193 165 1.5 0 1.6 1.4 03/20/2006 04:40:00 0.5 0.2 1.1 0.4 0.4 0.1 1.1 0.4 1 0.2 1.5 0.4 218 28 266 165 1.6 0 1.8 1.4 03/20/2006 04:50:00 0.5 0.3 1.1 0.4 0.5 0.2 1.1 0.4 1.1 0.2 1.5 0.4 314 17 280 165 1.4 0.1 1.6 1.4 03/20/2006 05:00:00 1.2 0.4 1.9 0.4 1.2 0.4 1.9 0.4 1.4 0.3 2.6 0.7 304 10 317 165 1.3 0 1.4 1.1 03/20/2006 05:10:00 1.1 0.4 1.9 0.4 1 0.4 1.9 0.4 1.5 0.3 2.3 0.7 320 22 302 165 1.2 0 1.4 1.1 03/20/2006 05:20:00 1.1 0.5 2.3 0.4 0.7 0.4 1.9 0.4 1.8 0.3 2.6 1.1 358 10 14 165 1 0 1.4 0.9 03/20/2006 05:30:00 1.9 0.5 3 1.1 0.9 0.5 3 0.4 2.3 0.4 3.4 1.5 358 5 349 165 1 0 1.4 0.9 03/20/2006 05:40:00 3 0.4 3.8 2.3 2.7 0.7 4.2 1.1 3.3 0.3 3.8 2.6 347 4 344 165 0.8 0.1 1.1 0.7 03/20/2006 05:50:00 3.2 0.4 4.2 2.3 3.1 0.5 4.6 1.5 3.3 0.5 4.2 1.9 339 12 342 165 0.6 0 0.9 0.4 03/20/2006 06:00:00 3.5 0.8 6.1 2.3 3.5 0.8 6.1 2.3 3.3 0.6 5.3 1.9 301 9 296 165 0.7 0.1 0.9 0.4 03/20/2006 06:10:00 4.9 0.4 6.1 3.8 4.9 0.4 6.1 3.8 4.3 0.5 6.1 3 305 5 304 165 0.7 0 0.9 0.7 03/20/2006 06:20:00 5.7 1.1 8.4 3 5.6 1.2 8.4 3 4.7 0.8 7.6 3 302 7 297 165 0.6 0 0.7 0.4 03/20/2006 06:30:00 8 0.7 9.9 6.5 8 0.7 9.5 6.1 6.3 1 9.5 4.2 297 5 291 165 0.5 0 0.7 0.4 03/20/2006 06:40:00 7.3 1 9.5 4.2 7.3 1 9.1 4.6 5.8 0.9 9.9 3.8 302 8 310 165 0.5 0 0.7 0.2 03/20/2006 06:50:00 8 0.9 9.9 4.9 8 0.9 9.9 5.3 6.6 1 9.1 4.6 296 5 293 165 0.5 0 0.7 0.2 03/20/2006 07:00:00 6.9 1 9.5 4.6 6.8 1 9.9 3.8 6 1 9.5 3.8 305 12 314 165 0.4 0 0.7 0.2 03/20/2006 07:10:00 5.3 0.8 7.6 3.4 5.2 0.7 7.2 3.4 5.3 0.7 7.6 3.8 324 13 313 165 0.5 0 0.7 0.4 03/20/2006 07:20:00 6.3 1.3 9.9 3 6.3 1.3 9.9 3 5.6 1.2 10.3 2.6 304 11 326 165 0.6 0.1 0.9 0.2 03/20/2006 07:30:00 8.4 1.3 11.5 4.9 8.4 1.3 11.1 4.6 7.1 1.1 10.7 4.6 304 9 297 165 0.5 0 0.9 0.2 03/20/2006 07:40:00 9.2 1 11.8 6.5 9.2 1 11.8 6.5 7 1 11.5 4.9 303 5 305 165 0.5 0 0.7 0.2 03/20/2006 07:50:00 10.2 1 13.7 8 10.1 1 13.7 7.6 7.6 1 11.5 5.7 301 5 304 165 0.3 0 0.7 0.2 03/20/2006 08:00:00 9.8 1.1 13 7.2 9.8 1.1 12.6 6.5 7.8 1.2 11.5 5.3 302 7 307 165 0.3 0 0.7 0.2 03/20/2006 08:10:00 10.7 1.3 14.1 8 10.6 1.3 14.5 6.8 8.6 1.2 11.8 6.1 305 5 304 165 0.4 0 0.7 0.2 03/20/2006 08:20:00 11.7 1 14.5 8 11.5 1 14.1 7.6 8.9 1.2 12.6 6.1 302 6 306 165 0.2 0 0.4 -0.1 03/20/2006 08:30:00 12 1 14.5 9.1 11.9 1 14.5 9.1 9 1.2 12.6 6.5 301 6 301 165 0 0 0.2 -0.1 03/20/2006 08:40:00 12.1 1.3 14.9 9.1 12 1.3 14.9 9.1 9.4 1.3 13 6.1 303 6 304 165 0.1 0 0.2 -0.1 03/20/2006 08:50:00 11.6 1 14.5 8.8 11.5 1 14.5 9.1 9.3 1.5 13 6.1 304 7 305 165 0.2 0 0.4 -0.1 03/20/2006 09:00:00 11.5 1 14.1 8.4 11.4 1.1 14.1 8.8 9.4 1.5 14.1 6.1 304 7 313 165 0.2 0 0.2 -0.1 03/20/2006 09:10:00 10.9 1.2 13.7 7.6 10.9 1.2 13.7 8 8.8 1.2 11.8 6.5 304 6 311 165 0.1 0 0.2 -0.1 03/20/2006 09:20:00 11.1 1.4 14.5 7.2 11 1.4 14.5 7.2 9 1.5 13 5.7 306 6 308 165 0.1 0 0.2 -0.1 03/20/2006 09:30:00 12.2 1.2 14.9 8.8 12 1.3 14.5 8 10 1.5 13.7 6.8 307 6 307 165 0.2 0 0.4 0.2 03/20/2006 09:40:00 11.7 1.2 14.9 7.2 11.6 1.2 14.5 7.2 10.4 1.5 14.1 6.8 309 7 305 165 0.3 0 0.7 0.2 03/20/2006 09:50:00 11.8 1.2 14.9 8.4 11.6 1.2 14.5 8.4 9.5 1.5 14.1 6.1 305 6 302 165 0.3 0 0.4 0.2 03/20/2006 10:00:00 11.1 1.4 14.9 8 10.9 1.4 14.5 7.6 9.5 1.4 13 6.1 308 6 305 165 0.3 0 0.4 0.2 03/20/2006 10:10:00 12.2 1.2 16.4 8.4 12.1 1.2 16.1 8.4 10.5 1.4 14.1 6.5 309 5 310 165 0.2 0 0.4 0.2 03/20/2006 10:20:00 12.3 1.1 14.9 9.5 12.2 1.1 14.5 9.5 10.4 1.5 14.1 7.2 307 6 310 165 0.5 0 0.7 0.2 03/20/2006 10:30:00 11.8 1.2 14.9 8.4 11.7 1.2 14.9 7.6 9.9 1.4 13 6.5 306 5 307 165 0.5 0 0.7 0.2 03/20/2006 10:40:00 11.9 1.3 15.3 7.6 11.8 1.3 14.9 7.2 9.4 1.2 12.6 6.8 302 6 298 165 0.6 0 0.9 0.7 03/20/2006 10:50:00 12.9 1.1 14.9 9.9 12.8 1.2 14.9 9.9 9.5 1.2 13 6.8 301 5 298 165 0.7 0 0.9 0.7 03/20/2006 11:00:00 12.8 1.7 16.8 9.1 12.7 1.7 16.8 8.8 10.4 1.5 14.5 6.5 304 6 305 165 0.8 0 0.9 0.7 03/20/2006 11:10:00 12.7 1.3 15.3 9.1 12.6 1.3 15.3 8.8 9.6 1.5 14.1 6.8 301 6 295 165 0.9 0 1.1 0.9 03/20/2006 11:20:00 13.5 1.3 16.4 10.3 13.4 1.3 16.8 9.9 10.6 1.5 14.9 7.2 302 6 304 165 1 0 1.4 0.9 03/20/2006 11:30:00 14.2 1.2 16.8 10.3 14.1 1.2 16.8 10.3 10.9 1.7 16.1 7.2 303 7 302 165 1.1 0 1.4 0.9 03/20/2006 11:40:00 15.3 1 17.6 12.6 15.3 1 17.6 12.2 11 1.2 14.9 8.8 301 5 300 165 1.3 0.1 1.6 1.1 03/20/2006 11:50:00 15.3 1.2 17.9 11.5 15.3 1.2 17.6 11.5 11.2 1.4 15.6 7.6 302 5 299 165 1.6 0 1.8 1.4 03/20/2006 12:00:00 15 1.2 18.3 11.8 14.9 1.3 18.3 11.5 11.6 1.5 15.3 8 304 6 298 165 1.8 0.1 2.1 1.6 03/20/2006 12:10:00 16.6 0.9 18.7 13.3 16.6 0.9 18.3 13 11.5 1.3 15.3 8.8 302 3 302 165 1.7 0.2 1.8 1.4 03/20/2006 12:20:00 16.2 1.4 19.1 11.5 16.1 1.5 19.1 11.5 11.9 1.5 16.8 8.8 302 4 302 165 1.4 0 1.6 1.1 03/20/2006 12:30:00 15.4 1 17.6 12.6 15.4 1 17.6 12.6 11.1 1.4 14.9 8 302 4 302 165 1.7 0 1.8 1.4 03/20/2006 12:40:00 16.6 1.1 19.1 12.2 16.6 1.1 18.7 12.2 12 1.3 16.1 8.8 302 3 301 165 2 0 2.3 1.8 03/20/2006 12:50:00 15.7 1.2 17.9 11.1 15.7 1.2 18.3 11.5 11.5 1.3 16.1 8.8 303 4 303 165 2 0.2 2.3 1.6 03/20/2006 13:00:00 15.8 1 18.3 12.6 15.7 1.1 18.3 12.6 11.7 1.3 16.1 8.8 303 3 302 165 1.7 0 1.8 1.4 03/20/2006 13:10:00 15.4 1.1 18.3 11.8 15.4 1.1 18.3 11.5 11.6 1.7 16.1 7.6 303 4 307 165 1.6 0 1.8 1.6 03/20/2006 13:20:00 15.2 1.4 18.7 11.1 15.1 1.4 18.3 10.7 11.6 1.9 16.8 7.6 303 5 304 165 1.7 0 1.8 1.4 03/20/2006 13:30:00 16 1.2 18.3 11.5 16 1.2 18.7 11.8 11.7 1.3 16.4 8 302 5 301 165 1.7 0 1.8 1.6 03/20/2006 13:40:00 15.3 1.2 18.7 12.6 15.2 1.3 18.3 12.2 12 1.5 16.1 8.4 305 5 301 165 1.8 0.1 2.3 1.6 03/20/2006 13:50:00 15.4 1.4 17.9 12.6 15.4 1.5 17.9 12.2 13 1.5 16.8 9.1 308 5 305 165 1.9 0 2.1 1.8 03/20/2006 14:00:00 15.7 1.4 19.1 12.2 15.6 1.4 19.5 12.2 13.9 2.3 19.1 9.5 310 6 310 165 2 0 2.3 1.8 03/20/2006 14:10:00 15.7 1.3 19.5 11.8 15.6 1.3 19.1 12.2 14.9 1.9 19.9 9.1 313 6 316 165 2.1 0.1 2.6 1.8 03/20/2006 14:20:00 15.4 1.1 18.7 11.1 15.3 1.1 18.3 11.5 14 1.7 18.3 9.5 311 6 312 165 2.2 0 2.6 1.6 03/20/2006 14:30:00 16.5 1.3 18.7 13.3 16.4 1.3 18.7 13 13.5 1.5 17.6 9.9 307 6 305 165 2.3 0 2.6 1.8 03/20/2006 14:40:00 17.1 1.1 20.2 14.1 17 1.1 19.9 14.1 14.7 1.5 17.9 11.1 308 4 305 165 2.2 0 2.6 1.8 03/20/2006 14:50:00 16.1 1.2 18.3 12.6 16 1.1 18.3 12.6 13.9 1.4 17.6 9.9 310 6 307 165 2.1 0.1 2.6 1.8 03/20/2006 15:00:00 16.3 1.1 18.7 13 16.3 1.1 18.7 13.3 13.9 1.7 17.9 9.9 308 5 309 165 1.8 0.2 2.6 1.1 03/20/2006 15:10:00 14.9 1.2 17.6 12.2 14.8 1.1 17.6 11.8 13.3 1.4 17.2 8.8 312 6 305 165 2.1 0.2 2.6 1.6 03/20/2006 15:20:00 14.5 1.3 17.9 10.3 14.4 1.2 17.6 10.3 12.7 1.7 17.2 8 309 7 296 165 1.9 0.1 2.3 1.4 03/20/2006 15:30:00 14 2.1 19.5 9.1 13.9 2.1 19.1 9.1 12.6 1.7 16.4 8 309 8 303 165 1.5 0.2 1.8 1.1 03/20/2006 15:40:00 10 1.2 13.3 7.2 9.5 1.5 13 4.9 9.7 1.2 13 6.8 335 15 316 165 1.2 0 1.4 1.1 03/20/2006 15:50:00 12.8 2.4 18.7 8 11.9 2.6 19.5 6.5 12 2.2 17.6 7.2 342 11 345 165 1 0 1.4 0.9 03/20/2006 16:00:00 15.9 1.9 21.4 10.3 15.3 2.2 20.6 8 15 2.1 21 9.5 342 8 353 165 1.1 0 1.6 0.9 03/20/2006 16:10:00 15.9 1.7 20.2 10.7 15.7 2.1 20.2 9.5 15.4 2 21.4 9.1 337 11 349 165 1.8 0.2 2.3 1.4 03/20/2006 16:20:00 16.3 2.1 22.1 11.8 15.9 2.6 21.8 9.5 16.3 2.1 22.1 11.1 341 9 330 165 1.4 0.1 1.8 1.4 03/20/2006 16:30:00 14.7 1.7 19.1 10.7 13.6 2.4 19.5 7.6 14.5 1.7 18.7 9.9 343 10 358 165 1.1 0 1.4 0.9 03/20/2006 16:40:00 14.1 2 18.3 8.4 13.7 2.4 18.7 7.2 13.5 2.1 19.1 9.1 334 13 341 165 1.1 0 1.4 0.9 03/20/2006 16:50:00 14.6 1.8 19.9 8.4 14.4 2.1 19.9 8 14.4 2 20.2 8.4 331 11 332 165 0.9 0.1 1.1 0.7 03/20/2006 17:00:00 15.7 2.2 21 11.5 15.2 2.2 21.4 10.3 15.2 2.4 21.4 9.1 334 12 350 165 1.1 0.3 1.6 0.7 03/20/2006 17:10:00 15.5 2.2 20.6 8.8 15.1 2.4 21 8.4 15.1 2.3 19.9 8.8 335 12 358 165 1.8 0 1.8 1.4 03/20/2006 17:20:00 16.2 1.8 23.3 10.3 16 2 22.9 9.9 15.6 1.9 21.4 11.5 327 13 314 165 1 0.2 1.6 0.7 03/20/2006 17:30:00 16.9 1.9 22.6 9.5 16.8 1.9 22.1 9.1 16.2 2.3 21.8 9.1 321 13 302 165 0.8 0 1.1 0.7 03/20/2006 17:40:00 16.7 1.7 21.8 11.5 16.6 1.7 21.4 11.8 16.2 1.9 22.1 10.3 326 11 320 165 0.5 0 0.7 0.2 03/20/2006 17:50:00 18.7 2.6 27.1 11.8 18.6 2.5 27.1 11.8 17.8 2.3 26.3 11.5 314 9 310 165 0.4 0 0.7 0.2 03/20/2006 18:00:00 18.4 2.6 27.1 11.8 18.3 2.6 27.1 11.5 17.2 2.7 24 9.9 314 11 315 165 0.4 0 0.7 0.2 03/20/2006 18:10:00 17.6 1.7 22.1 9.5 17.5 1.7 21.8 9.9 16.5 2.1 23.7 9.1 315 10 309 165 0.3 0 0.7 0.2 03/20/2006 18:20:00 17.2 2.2 24 9.9 17.2 2.2 24 9.5 15.9 2.5 24.8 9.9 314 11 331 165 0.2 0 0.4 0.2 03/20/2006 18:30:00 16.1 2 22.1 10.3 16.1 2 22.1 10.7 15.4 2 21.8 10.3 314 9 308 165 0.2 0 0.2 -0.1 03/20/2006 18:40:00 16.5 2.3 22.9 11.8 16.4 2.3 22.9 11.5 15.6 2 22.1 9.9 316 9 294 165 0.2 0 0.2 0.2 03/20/2006 18:50:00 15.8 1.9 21.4 10.3 15.7 1.9 21.4 10.7 14.9 2.1 19.9 9.5 315 8 314 165 0.2 0 0.4 0.2 03/20/2006 19:00:00 14.5 1.8 20.6 10.3 14.4 1.9 21 10.3 13.9 2 19.5 9.5 322 10 344 165 0.1 0 0.2 -0.1 03/20/2006 19:10:00 15.4 1.7 20.6 10.7 15.3 1.7 20.6 10.7 15 1.7 20.2 10.3 319 9 317 165 0 0 0.2 -0.1 03/20/2006 19:20:00 16.1 1.7 21.4 10.7 16 1.7 21.4 10.7 14.9 1.6 20.2 8.8 314 8 322 165 -0.3 0.1 -0.1 -0.5 03/20/2006 19:30:00 17.2 1.3 21 13.3 17.1 1.3 21.4 13.7 16.2 1.5 21.8 12.6 313 6 308 165 -0.3 0 -0.3 -0.5 03/20/2006 19:40:00 18.1 1.7 24.8 13.3 18 1.7 24.4 12.6 17.2 1.9 25.2 12.2 315 8 313 165 -0.3 0 -0.1 -0.5 03/20/2006 19:50:00 18.3 1.6 22.9 13 18.1 1.6 22.6 13 17.3 1.8 22.6 11.5 315 6 321 165 -0.4 0 -0.3 -0.5 03/20/2006 20:00:00 19.7 1.3 23.3 16.4 19.6 1.3 23.3 15.6 19 1.4 23.7 14.9 314 6 311 165 -0.3 0 -0.1 -0.5 03/20/2006 20:10:00 19.3 1.7 23.7 14.9 19.2 1.7 24 14.9 18.2 1.7 22.6 13 313 5 304 165 -0.3 0 -0.3 -0.5 03/20/2006 20:20:00 20.7 1.6 24.4 16.1 20.6 1.6 24 16.1 20.1 1.7 24.4 14.9 314 5 312 165 -0.3 0 -0.3 -0.5 03/20/2006 20:30:00 20.5 1.3 23.3 17.2 20.4 1.4 23.7 16.4 19.8 1.6 24 16.4 313 5 313 165 -0.4 0 -0.1 -0.5 03/20/2006 20:40:00 21.3 1.6 26.3 17.2 21.3 1.7 25.6 17.2 20.1 1.7 24.8 15.6 311 5 304 165 -0.6 0 -0.3 -0.8 03/20/2006 20:50:00 22.1 1.6 26.8 16.4 22 1.6 26.8 16.8 21.4 1.7 25.2 15.6 312 5 311 165 -0.3 0.1 -0.1 -0.8 03/20/2006 21:00:00 22.3 1.5 25.6 17.2 22.3 1.5 25.6 16.8 21.5 1.6 25.6 17.2 311 5 306 165 -0.5 0 -0.3 -0.8 03/20/2006 21:10:00 22.4 1.7 27.1 17.6 22.3 1.6 26.3 17.9 21 1.9 26 14.9 310 6 313 165 -0.6 0.1 -0.3 -0.8 03/20/2006 21:20:00 22.7 1.5 26.8 18.7 22.6 1.5 26.8 18.3 21.1 1.9 26.8 14.9 310 6 315 165 -0.7 0 -0.5 -0.8 03/20/2006 21:30:00 21 1.7 26.3 16.8 20.9 1.7 25.6 16.8 19.4 1.7 24.4 14.9 311 6 311 165 -0.8 0 -0.5 -1 03/20/2006 21:40:00 21.2 1.8 27.9 14.9 21.1 1.8 28.3 14.9 20.1 2.2 28.3 14.9 314 8 304 165 -0.5 0 -0.1 -1 03/20/2006 21:50:00 21.6 1.7 26.3 16.8 21.5 1.6 26.3 16.8 20.6 1.7 25.6 15.3 313 6 310 165 -0.6 0 -0.3 -0.8 03/20/2006 22:00:00 22.9 1.9 30.2 17.9 22.8 1.9 29.4 17.6 21.8 2.3 29.4 14.5 313 6 303 165 -0.6 0.2 -0.1 -0.8 03/20/2006 22:10:00 22.7 1.7 27.5 17.9 22.6 1.6 27.5 17.9 22.2 1.7 27.1 17.9 316 7 327 165 -0.5 0.1 -0.1 -0.8 03/20/2006 22:20:00 22.3 1.8 26.8 17.6 22.2 1.8 26.8 16.8 21.7 1.9 26.8 16.8 316 8 308 165 -0.2 0.2 0.2 -0.5 03/20/2006 22:30:00 21.6 1.6 25.6 16.8 21.5 1.6 26 16.8 21.2 1.7 26 14.9 315 7 312 165 -0.2 0 -0.1 -0.5 03/20/2006 22:40:00 21.7 1.7 29.8 16.8 21.6 1.7 29.8 16.8 21.4 1.7 26.8 16.1 318 8 298 165 -0.1 0 0.2 -0.3 03/20/2006 22:50:00 21.4 2 29.4 16.8 21.3 2 29.1 16.8 20.9 2.1 27.1 16.4 316 7 318 165 -0.2 0 -0.1 -0.3 03/20/2006 23:00:00 21.9 2.3 27.9 17.2 21.8 2.3 28.3 16.4 21.6 2.1 27.5 16.8 319 8 309 165 -0.2 0 -0.1 -0.5 03/20/2006 23:10:00 23.4 2.1 30.6 17.6 23.3 2.1 30.9 18.3 23 2.2 30.6 17.9 317 7 313 165 -0.3 0 -0.1 -0.5 03/20/2006 23:20:00 22.4 1.6 26.8 18.3 22.3 1.7 26.3 17.9 22.2 1.7 26.3 17.9 317 7 305 165 -0.5 0 -0.3 -0.8 03/20/2006 23:30:00 21.9 2.1 27.1 16.4 21.8 2.1 27.1 16.8 21.7 2.2 27.1 16.1 317 8 310 165 -0.5 0 -0.3 -0.8 03/20/2006 23:40:00 21.9 2.1 29.1 17.2 21.9 2.1 28.7 17.6 21.6 2.3 29.1 16.4 316 8 304 165 -0.5 0 -0.3 -0.8 03/20/2006 23:50:00 21.2 2.6 29.1 13.7 21.2 2.6 29.1 13 20.9 2.6 29.4 12.2 317 8 298 165 -0.5 0 -0.3 -0.8 03/21/2006 00:00:00 20.2 1.9 29.1 15.3 20.1 2 28.7 14.9 19.9 2 26.3 14.9 316 9 310 165 -0.6 0 -0.3 -0.8 03/21/2006 00:10:00 20.8 2.1 27.9 16.1 20.8 2.1 27.5 16.1 20.1 2.2 27.5 14.1 316 9 318 165 -0.8 0 -0.5 -1 03/21/2006 00:20:00 21.7 2.4 28.3 16.1 21.6 2.4 27.9 15.6 21.3 2.6 28.3 15.3 318 9 329 165 -0.5 0 -0.3 -0.8 03/21/2006 00:30:00 21.8 1.6 26.8 17.2 21.7 1.6 26.3 17.2 21.4 1.8 27.5 16.8 317 7 326 165 -0.7 0.2 -0.3 -0.8 03/21/2006 00:40:00 21.8 1.8 27.5 17.6 21.7 1.9 27.9 17.6 21.1 2.2 28.3 15.6 314 7 310 165 -0.7 0 -0.3 -1 03/21/2006 00:50:00 21.3 2.4 29.1 16.4 21.3 2.4 29.4 16.1 21 2.6 28.3 15.6 317 8 321 165 -0.6 0 -0.3 -1 03/21/2006 01:00:00 22.2 2.3 28.7 16.4 22.2 2.3 28.7 16.1 21.7 2.5 27.9 14.5 318 9 321 165 -0.8 0 -0.5 -1 03/21/2006 01:10:00 21.8 1.9 27.9 15.6 21.8 1.8 27.1 16.4 21.4 2 26.3 13.7 316 6 310 165 -0.9 0 -0.8 -1.2 03/21/2006 01:20:00 22.8 1.6 27.5 17.9 22.8 1.6 27.1 17.9 22.6 1.7 27.9 16.4 315 6 316 165 -1.1 0 -0.8 -1.2 03/21/2006 01:30:00 22.8 2.2 30.2 17.2 22.7 2.2 30.2 17.2 22.1 2.4 29.8 16.4 314 7 310 165 -1.2 0 -0.8 -1.4 03/21/2006 01:40:00 23.2 1.8 29.4 18.7 23.2 1.8 29.1 19.5 22.8 2 27.9 16.4 314 6 306 165 -1 0 -0.8 -1.4 03/21/2006 01:50:00 23.6 1.7 28.3 19.1 23.6 1.7 28.3 19.1 23.2 1.8 28.3 17.2 313 6 313 165 -1.3 0.1 -1 -1.4 03/21/2006 02:00:00 23.4 1.9 27.9 17.6 23.3 2 27.9 17.9 23 2.3 28.3 16.8 315 7 320 165 -1.2 0.1 -1 -1.4 03/21/2006 02:10:00 22.7 2 28.3 16.4 22.6 2.1 28.3 16.4 22.2 2 27.5 15.6 316 8 315 165 -1.1 0 -0.8 -1.4 03/21/2006 02:20:00 22.6 2.2 29.1 17.6 22.5 2.2 28.7 17.6 22.2 2.2 27.9 16.4 316 8 317 165 -1 0.2 -0.5 -1.4 03/21/2006 02:30:00 21.8 2.3 30.9 15.3 21.8 2.3 30.6 14.5 21.2 2.4 29.4 14.5 316 8 303 165 -1.2 0 -0.8 -1.4 03/21/2006 02:40:00 22.3 2.3 29.4 17.2 22.3 2.2 29.4 17.2 21.8 2.3 30.6 16.8 315 8 298 165 -1.2 0.1 -0.8 -1.4 03/21/2006 02:50:00 21.8 2.4 27.9 17.2 21.8 2.4 27.5 16.8 21.4 2.7 29.8 16.1 318 10 308 165 -0.8 0.1 -0.5 -1.2 03/21/2006 03:00:00 21.4 2 27.5 15.6 21.3 2 27.5 15.6 20.9 2.1 28.3 14.9 317 8 310 165 -1 0 -0.5 -1.2 03/21/2006 03:10:00 21.9 2.2 29.4 16.4 21.8 2.2 28.7 16.8 21.3 2.4 27.9 14.9 316 8 307 165 -0.8 0.1 -0.5 -1.2 03/21/2006 03:20:00 21.6 2.4 29.4 14.1 21.6 2.4 29.4 15.3 21 2.8 30.2 11.5 317 10 307 165 -0.7 0.2 -0.3 -1.2 03/21/2006 03:30:00 21.6 2.4 27.5 15.3 21.5 2.3 27.5 15.6 20.9 2.4 27.9 13.3 315 8 317 165 -0.6 0.1 -0.3 -0.8 03/21/2006 03:40:00 21.6 2.4 27.5 15.6 21.6 2.4 27.1 15.3 20.8 2.7 28.3 13.7 317 10 305 165 -0.6 0.1 -0.3 -0.8 03/21/2006 03:50:00 20.3 2.5 28.3 13.3 20.2 2.4 27.5 13.3 19.4 2.4 26.3 11.8 319 12 316 165 -0.6 0.2 -0.3 -0.8 03/21/2006 04:00:00 20.2 2.4 30.2 14.1 20.1 2.4 31.3 14.1 19.6 2.4 27.1 13 319 11 301 165 -0.6 0.2 -0.1 -1 03/21/2006 04:10:00 20.6 2.2 27.9 14.1 20.5 2.2 27.1 14.1 20 2.2 26.8 14.5 321 9 331 165 -0.7 0.1 -0.3 -0.8 03/21/2006 04:20:00 19.7 2.2 26.8 13.7 19.6 2.2 26 13.3 19.3 2.5 26.3 13 325 13 321 165 -0.5 0 -0.3 -0.8 03/21/2006 04:30:00 19.7 2.6 27.1 13.7 19.7 2.6 27.1 13.3 19.2 2.8 27.5 12.6 324 11 336 165 -0.5 0 -0.3 -0.5 03/21/2006 04:40:00 20 2.1 25.6 14.5 19.9 2.1 25.2 14.1 19.4 2.4 26 13 325 11 320 165 -0.3 0 -0.1 -0.5 03/21/2006 04:50:00 19.3 2.2 26 13.3 19.2 2.1 26 13 18.6 2.1 23.7 12.6 321 13 307 165 -0.5 0 -0.3 -0.8 03/21/2006 05:00:00 19.3 2 25.2 14.5 19.1 2.2 25.2 13.3 19 2.3 25.6 13.3 327 12 319 165 -0.6 0 -0.5 -0.8 03/21/2006 05:10:00 18.9 2.2 24.4 10.7 18.8 2.1 24 10.7 17.9 2.4 25.2 11.5 320 13 324 165 -0.6 0 -0.3 -0.8 03/21/2006 05:20:00 18.5 2.4 24.4 12.6 18.4 2.6 24.4 9.5 17.5 2.5 25.6 9.5 318 14 307 165 -0.6 0 -0.3 -0.8 03/21/2006 05:30:00 19.2 2.2 26 14.1 19.1 2.2 26.8 13.7 18.2 2.4 26.8 12.2 319 10 338 165 -0.4 0 -0.3 -0.5 03/21/2006 05:40:00 18.4 2.5 27.1 12.6 18.4 2.4 27.9 12.6 17.2 2.3 23.7 12.6 317 11 308 165 -0.3 0.1 -0.1 -0.5 03/21/2006 05:50:00 18.7 2.4 26 13 18.6 2.5 25.6 13 17 2.4 23.3 11.1 313 11 322 165 -0.3 0 -0.1 -0.5 03/21/2006 06:00:00 17.4 1.8 22.1 11.8 17.3 1.9 21.8 11.8 16.9 2 21.4 12.2 326 12 319 165 -0.5 0 -0.3 -0.5 03/21/2006 06:10:00 16.5 2.1 22.6 11.1 16.4 2.2 22.9 10.3 15.9 1.9 20.6 11.5 328 12 319 165 -0.5 0 -0.3 -0.8 03/21/2006 06:20:00 16.2 2.2 21.4 10.3 16.2 2.3 22.1 9.5 15.7 2.3 21 9.5 331 12 338 165 -0.5 0 -0.5 -0.5 03/21/2006 06:30:00 16.1 2.2 22.1 11.8 16 2.3 22.1 11.8 15.6 2.4 22.1 10.7 331 10 332 165 -0.5 0 -0.3 -0.8 03/21/2006 06:40:00 17.4 2.7 24 11.5 17.1 2.7 24 10.7 17 2.9 24.4 11.5 335 10 328 165 -0.5 0 -0.3 -0.5 03/21/2006 06:50:00 17.2 2.1 22.9 12.6 17.2 2.2 23.3 11.8 17 2.2 21.8 11.8 334 9 316 165 -0.4 0 -0.3 -0.5 03/21/2006 07:00:00 16.4 2.1 22.9 10.7 16.3 2.2 22.6 11.1 16.2 2.2 21.8 11.5 336 10 343 165 -0.5 0 -0.3 -0.5 03/21/2006 07:10:00 17 2.2 22.6 11.8 17.1 2.3 22.9 11.5 16.6 2.6 23.7 9.5 332 10 348 165 -0.4 0 -0.1 -0.5 03/21/2006 07:20:00 15.8 2.3 21.4 9.9 15.8 2.4 21.8 10.3 15.5 2.4 22.1 10.3 332 10 337 165 -0.5 0 -0.3 -0.8 03/21/2006 07:30:00 17.1 2.2 24 11.1 17 2.3 24 8.8 17.3 2.1 23.7 12.6 337 9 332 165 -0.4 0 -0.3 -0.8 03/21/2006 07:40:00 17.1 2.1 22.1 11.5 17 2.3 22.1 11.5 17.1 2.2 22.6 9.9 334 10 333 165 -0.3 0 -0.3 -0.5 03/21/2006 07:50:00 16.5 1.7 21.4 12.2 16.5 1.9 21.8 11.8 16.5 1.9 21.4 12.2 334 9 339 165 -0.3 0 -0.3 -0.5 03/21/2006 08:00:00 16.9 1.8 22.6 11.1 17 2.1 22.6 11.1 17.1 2.1 22.6 11.5 336 9 351 165 -0.3 0 -0.1 -0.5 03/21/2006 08:10:00 15.9 1.7 20.6 11.5 15.9 1.9 19.9 11.1 15.5 2 20.2 9.9 331 9 325 165 -0.3 0 -0.1 -0.5 03/21/2006 08:20:00 15.6 1.9 20.6 9.5 15.5 2.1 21.8 9.9 15.3 2.2 21.8 10.3 334 10 335 165 -0.3 0 -0.1 -0.5 03/21/2006 08:30:00 15.9 2.3 22.1 11.1 15.8 2.5 22.1 9.5 15.9 2.4 22.6 10.7 335 9 340 165 -0.2 0 -0.1 -0.5 03/21/2006 08:40:00 16.5 1.8 22.9 12.6 16.5 1.9 22.9 10.3 16.4 2.1 23.7 11.5 333 8 339 165 0 0 0.2 -0.3 03/21/2006 08:50:00 14.8 1.7 19.9 10.7 14.7 1.8 19.5 9.1 14.6 1.9 19.5 9.9 332 10 333 165 -0.1 0 0.2 -0.3 03/21/2006 09:00:00 15.2 2.1 21.8 10.3 15.1 2.2 22.1 10.7 15.1 2.2 21 9.9 334 9 336 165 0 0 0.2 -0.1 03/21/2006 09:10:00 15.1 1.9 20.6 9.9 15.1 2 20.2 9.1 15 1.9 19.9 9.9 331 9 325 165 0.1 0 0.2 -0.3 03/21/2006 09:20:00 15 1.8 19.5 9.9 15.1 1.9 19.9 9.5 14.9 2 19.5 9.5 333 8 339 165 0.2 0 0.2 -0.1 03/21/2006 09:30:00 14.4 1.7 17.9 9.9 14.3 1.8 18.3 8.8 14.1 1.6 18.7 9.9 334 9 353 165 0.2 0 0.4 0.2 03/21/2006 09:40:00 14.6 1.9 20.6 9.9 14.3 2 20.2 9.5 14.3 2.1 20.6 9.1 333 11 1 165 0.2 0 0.4 0.2 03/21/2006 09:50:00 15.4 1.8 20.2 11.5 15.4 1.9 20.2 11.1 15.4 2 21.4 10.7 332 10 350 165 0.5 0 0.9 0.2 03/21/2006 10:00:00 15 2.1 20.2 10.3 14.4 2.7 21 8 14.8 2 19.9 9.9 335 13 327 165 0.5 0 0.7 0.4 03/21/2006 10:10:00 13.9 1.5 18.3 9.9 13.8 1.7 18.3 8.4 13.6 1.6 17.2 9.1 335 9 332 165 0.5 0 0.7 0.4 03/21/2006 10:20:00 13.7 1.5 17.9 9.9 13.2 2 17.9 7.6 13.6 1.7 18.3 9.1 341 10 8 165 0.5 0 0.7 0.4 03/21/2006 10:30:00 13.6 1.5 16.8 9.9 13.5 1.7 17.6 7.6 13.6 1.5 17.2 10.3 338 8 345 165 0.7 0 0.9 0.4 03/21/2006 10:40:00 13.6 1.3 17.2 9.9 12.5 1.9 16.1 7.2 13.5 1.5 17.2 9.5 346 9 354 165 0.8 0 1.1 0.7 03/21/2006 10:50:00 13.1 1.2 16.8 9.5 13.1 1.3 16.8 9.9 12.9 1.3 17.2 9.5 335 8 328 165 0.9 0 1.4 0.9 03/21/2006 11:00:00 14.6 1.4 18.7 10.7 12.8 2.3 18.3 7.2 14.4 1.4 17.9 9.9 348 10 338 165 1.2 0 1.4 0.9 03/21/2006 11:10:00 14.6 1.3 18.3 9.9 13.2 2 17.2 7.2 14.5 1.4 18.7 9.9 349 7 349 165 1.4 0 1.6 1.4 03/21/2006 11:20:00 13.4 1.7 19.5 9.9 12.9 1.7 17.9 9.1 13.3 1.7 18.3 9.5 341 9 355 165 1.4 0 1.6 1.4 03/21/2006 11:30:00 14.2 1.9 21 9.9 13.1 2.1 19.9 7.2 14.2 2 23.7 9.9 346 9 354 165 1.4 0 1.6 1.1 03/21/2006 11:40:00 14 1.8 18.3 8.8 13.8 2.1 19.1 8 14.1 1.7 18.3 8.8 341 8 342 165 1.3 0 1.4 1.4 03/21/2006 11:50:00 13.5 1.5 17.6 10.3 13.1 1.8 17.2 7.2 13.2 1.5 17.2 8.4 339 11 327 165 1.4 0 1.6 1.4 03/21/2006 12:00:00 14.6 1.8 19.9 9.9 13.4 2.1 20.2 8.8 14.5 2 20.6 10.3 346 11 348 165 1.5 0 1.6 1.4 03/21/2006 12:10:00 14.9 2.2 21 9.5 13.4 2.3 19.1 7.6 14.9 2.3 20.2 8.8 347 10 350 165 1.5 0 1.8 1.4 03/21/2006 12:20:00 17 2.1 22.1 11.8 15.2 2.9 22.1 8.4 17.1 2.2 22.1 10.7 350 7 349 165 1.4 0 1.6 1.4 03/21/2006 12:30:00 16.1 2 22.1 11.8 14.2 2.7 21 8.8 16.2 2.1 21.8 11.5 349 9 352 165 1.7 0 1.8 1.4 03/21/2006 12:40:00 16.5 2 21.4 11.8 14.7 2.4 20.6 8.8 16.1 2.2 22.9 10.7 348 8 353 165 1.7 0 1.8 1.6 03/21/2006 12:50:00 16.8 1.9 22.1 12.2 15.1 2.6 22.1 8.4 16.2 2.1 21.4 11.1 349 8 351 165 1.8 0 1.8 1.6 03/21/2006 13:00:00 17.7 2.2 22.1 10.7 15.1 3.2 21.4 8.4 17.5 2.1 21.8 10.3 351 8 0 165 1.9 0.1 2.3 1.6 03/21/2006 13:10:00 16.3 2 21 10.7 14.5 2.5 21.4 8.8 15.7 2 20.2 10.7 349 6 356 165 1.8 0 1.8 1.6 03/21/2006 13:20:00 16.6 2.2 21 10.7 14.1 2.4 20.6 8.8 16.2 2.3 21.8 10.3 350 7 353 165 1.8 0.1 2.1 1.6 03/21/2006 13:30:00 16.3 1.7 21.4 12.6 14.5 2.3 19.5 9.1 16 1.7 20.2 11.5 349 8 353 165 1.9 0 2.3 1.6 03/21/2006 13:40:00 17.4 1.7 22.9 12.6 14.8 2.6 21.4 9.5 17 1.7 22.9 11.8 352 8 9 165 1.8 0 1.8 1.6 03/21/2006 13:50:00 16.1 1.3 19.5 11.8 13.4 2.4 19.1 8.8 15.5 1.5 19.1 9.9 352 8 358 165 2 0 2.3 1.8 03/21/2006 14:00:00 15 1.5 20.2 11.8 12.5 2.5 18.3 7.6 14.6 1.6 20.2 11.1 352 9 11 165 2 0 2.3 1.8 03/21/2006 14:10:00 15.8 1.7 20.2 11.5 12.2 2.4 17.9 7.6 15.3 1.7 19.9 11.1 354 7 351 165 2 0 2.3 1.8 03/21/2006 14:20:00 14.1 1.7 19.1 9.5 11.7 2.1 19.1 6.5 13.7 1.7 19.5 8.4 352 7 352 165 2 0 2.3 1.8 03/21/2006 14:30:00 14.8 1.8 20.6 10.7 11.8 2.5 20.6 7.2 14.5 1.7 20.6 10.7 353 8 351 165 2.1 0 2.3 1.8 03/21/2006 14:40:00 14.5 1.9 22.6 10.7 11.9 2.3 20.2 7.6 14.3 2 21.8 9.9 352 6 348 165 2 0 2.3 1.8 03/21/2006 14:50:00 13.7 1.8 19.1 9.5 11.8 2.5 18.3 6.8 13.6 1.8 19.9 10.3 351 8 8 165 2.1 0 2.3 1.8 03/21/2006 15:00:00 13.9 1.5 17.6 9.9 11.7 1.9 16.8 8 13.8 1.5 17.2 9.5 351 7 356 165 2.2 0.1 2.6 1.8 03/21/2006 15:10:00 14.2 1.8 21.4 8.8 12.1 2.2 19.1 8 13.9 2 20.6 8.4 352 9 15 165 2.3 0 2.6 2.1 03/21/2006 15:20:00 14.9 1.9 20.2 10.3 12.2 2.3 17.9 7.2 14.5 1.9 20.6 9.9 351 8 5 165 2.3 0 2.6 2.1 03/21/2006 15:30:00 14.3 1.5 19.5 10.7 12.3 2.1 17.2 7.6 13.9 1.7 19.1 9.5 350 6 3 165 2.2 0 2.3 1.8 03/21/2006 15:40:00 14 1.9 19.5 10.7 12 2.2 17.9 6.8 13.7 2 19.1 9.1 349 8 359 165 2 0 2.3 1.8 03/21/2006 15:50:00 15 2.3 21 10.3 11.3 2.1 16.8 7.2 14.6 2.2 19.9 9.1 355 7 1 165 2.1 0 2.3 1.8 03/21/2006 16:00:00 14.6 1.9 21 11.1 11.7 2.1 17.9 7.6 14.7 1.9 21.4 10.7 355 8 9 165 2.1 0 2.3 1.8 03/21/2006 16:10:00 14.6 2 20.2 10.3 11.6 2.1 17.2 6.8 14.5 2.2 21 9.9 354 8 10 165 2.3 0 2.6 2.1 03/21/2006 16:20:00 14.9 1.8 20.2 10.7 13.1 2.6 20.6 7.2 14.5 1.9 19.1 9.9 349 7 349 165 2.1 0 2.3 1.8 03/21/2006 16:30:00 14.7 1.8 19.9 9.5 12.6 2.5 18.3 6.5 14.4 1.9 20.2 9.1 350 8 354 165 2 0 2.3 1.8 03/21/2006 16:40:00 15.4 1.5 19.1 11.1 13.6 2.6 18.3 7.6 15.1 1.6 19.5 10.3 350 8 353 165 2 0 2.3 1.8 03/21/2006 16:50:00 14.4 1.7 20.6 10.7 12.1 2.3 17.2 7.2 14.3 1.7 19.9 10.7 350 8 359 165 1.9 0 2.1 1.8 03/21/2006 17:00:00 15.1 1.8 19.1 10.7 11.7 2.5 17.6 6.8 14.9 1.9 19.5 10.3 356 8 356 165 2 0 2.3 1.8 03/21/2006 17:10:00 13 1.7 18.7 9.5 11 2.2 17.6 6.5 12.9 1.9 19.9 8.4 351 8 356 165 1.9 0 2.3 1.8 03/21/2006 17:20:00 13.8 1.4 17.6 9.9 10.5 1.9 16.8 6.8 13.8 1.6 19.1 10.3 355 7 350 165 2 0 2.3 1.8 03/21/2006 17:30:00 14.2 1.7 19.1 9.1 11.8 2.4 18.3 7.6 14.3 1.7 19.9 8.4 352 7 350 165 2 0.1 2.3 1.8 03/21/2006 17:40:00 13 1.3 16.8 8.8 11.2 2.2 17.6 6.8 12.9 1.3 16.4 9.5 351 7 350 165 1.9 0 1.8 1.8 03/21/2006 17:50:00 13.1 1.7 18.3 8.8 11.1 2.2 17.9 6.1 13.1 1.6 17.6 8.8 351 7 352 165 2 0 2.3 1.8 03/21/2006 18:00:00 12.6 1.9 17.9 7.6 12 2.6 17.9 6.8 12.3 1.9 17.9 8 347 7 351 165 1.9 0 2.1 1.8 03/21/2006 18:10:00 13.4 2 18.7 9.5 11.6 2.4 19.1 6.8 13.2 1.8 17.2 9.1 351 8 359 165 2.1 0 2.3 1.6 03/21/2006 18:20:00 13.4 1.6 17.9 8.8 11.9 2.4 17.2 6.8 13.5 1.7 18.3 7.2 350 9 346 165 2.1 0 2.3 1.8 03/21/2006 18:30:00 13.6 1.5 19.1 9.1 12.8 2.1 17.2 7.2 13.5 1.6 18.3 9.1 348 6 3 165 1.9 0 2.1 1.8 03/21/2006 18:40:00 13.1 1.3 16.8 9.5 11.9 2.6 17.2 6.8 13.3 1.3 16.8 9.5 351 6 359 165 1.9 0 2.1 1.8 03/21/2006 18:50:00 12.1 1.6 16.1 8 11 2.5 16.8 6.1 12.2 1.8 15.6 6.5 351 9 6 165 1.9 0 2.1 1.8 03/21/2006 19:00:00 12.2 1.5 15.6 8.8 11 2.6 17.6 5.7 12.2 1.7 16.8 8.4 351 9 351 165 1.9 0 2.1 1.8 03/21/2006 19:10:00 11.3 1.4 16.4 8 10.7 2.4 17.2 5.7 11.5 1.5 15.6 7.6 348 7 351 165 1.8 0 2.1 1.8 03/21/2006 19:20:00 11.6 1.2 14.9 8.4 11.2 2.1 17.6 6.5 11.5 1.4 15.3 7.6 345 9 348 165 1.8 0 1.8 1.6 03/21/2006 19:30:00 11.1 1.3 15.3 8.4 11.5 1.9 17.2 6.8 11.1 1.3 14.9 8 343 6 340 165 1.8 0 1.8 1.6 03/21/2006 19:40:00 10.2 1.3 13.7 6.8 10.7 1.8 14.9 5.7 10.1 1.3 13.3 6.8 340 0 340 165 1.7 0 1.8 1.6 03/21/2006 19:50:00 11.1 1.4 14.9 6.8 11.6 1.8 16.4 6.5 11.2 1.5 15.3 7.6 340 0 340 165 1.7 0 1.8 1.6 03/21/2006 20:00:00 10.9 1.3 14.9 5.3 11.3 1.9 16.1 6.1 10.9 1.3 14.1 6.5 340 0 340 165 1.8 0.1 2.1 1.4 03/21/2006 20:10:00 10.5 1.3 14.9 6.8 11.1 1.5 15.6 6.8 10.5 1.4 14.5 7.2 340 0 340 165 1.8 0 1.8 1.6 03/21/2006 20:20:00 11 1.2 14.9 7.6 11.6 1.8 16.4 7.2 10.9 1.3 14.5 6.8 340 0 340 165 1.8 0 1.8 1.6 03/21/2006 20:30:00 10.5 1.4 14.9 6.8 11.3 1.9 16.4 6.8 10.3 1.5 13.7 6.8 340 0 340 165 1.8 0 1.8 1.6 03/21/2006 20:40:00 10.4 0.8 13.3 8 11.4 1.5 15.3 6.1 10.2 1 13 7.6 340 0 340 165 1.9 0 1.8 1.8 03/21/2006 20:50:00 9.9 1 12.6 7.2 11.1 1.3 14.5 7.2 10 1 12.6 6.5 340 0 340 165 1.8 0 1.8 1.6 03/21/2006 21:00:00 10.5 1.2 14.9 7.2 12 1.6 17.9 7.6 10.9 1.3 15.3 8 340 0 340 165 1.8 0 1.8 1.6 03/21/2006 21:10:00 10.1 1.1 13 7.6 11.5 1.5 15.6 7.6 10.4 1.2 13.3 6.8 340 0 340 165 1.8 0 1.8 1.6 03/21/2006 21:20:00 9.2 1 12.6 6.8 10.3 1.2 14.9 7.6 9.5 1 12.2 6.8 340 0 340 165 1.8 0 1.8 1.6 03/21/2006 21:30:00 9.5 1.4 13 6.5 10.8 1.8 15.3 6.5 9.8 1.4 13 6.1 340 0 340 165 1.8 0 1.8 1.6 03/21/2006 21:40:00 9.9 1 12.6 7.6 11.4 1.1 14.1 8.4 10.3 1.1 12.6 6.5 339 0 339 165 1.9 0 1.8 1.6 03/21/2006 21:50:00 9.1 1.1 12.6 6.1 10.3 1.3 13.7 7.6 9.4 1.2 12.2 6.1 339 0 339 165 1.9 0 2.1 1.8 03/21/2006 22:00:00 8.4 1 10.7 6.1 9.3 1.3 12.2 5.3 8.6 1 11.1 6.1 339 0 339 165 1.9 0 2.1 1.8 03/21/2006 22:10:00 9 1 11.8 6.8 10.1 1.4 13.3 6.1 9.3 1.2 13 6.5 339 0 339 165 2 0 2.3 1.8 03/21/2006 22:20:00 9 1.1 11.8 6.1 10.1 1.3 13.3 5.7 9.3 1.2 12.2 6.1 339 0 339 165 2 0 2.3 1.8 03/21/2006 22:30:00 9.4 1.2 12.2 6.1 10.7 1.4 14.9 7.2 9.6 1.5 13 5.3 339 0 339 165 2.1 0 2.3 1.8 03/21/2006 22:40:00 9.6 1.3 14.1 6.1 10.3 1.9 16.4 5.7 10.1 1.3 13.3 6.8 339 1 339 165 2.3 0 2.6 2.1 03/21/2006 22:50:00 9.9 1.1 13.3 6.8 10.8 1.3 14.9 7.6 10.5 1.2 14.5 7.6 338 1 338 165 2.3 0 2.6 2.1 03/21/2006 23:00:00 10.3 1.2 14.1 7.2 11.1 1.4 15.6 7.6 10.7 1.4 14.9 7.2 337 3 338 165 2.4 0 2.6 2.3 03/21/2006 23:10:00 10.7 1.2 14.1 7.2 11.1 1.4 14.9 7.2 10.9 1.4 14.5 8 335 6 345 165 2.5 0 2.8 2.6 03/21/2006 23:20:00 10.5 1.1 14.1 7.6 10.5 1.2 14.1 7.2 10.4 1.1 14.5 7.6 334 6 333 165 2.6 0 2.8 2.6 03/21/2006 23:30:00 11.1 1.2 14.1 8.8 11.1 1.5 14.9 6.5 11 1.3 14.1 8.8 340 5 341 165 2.6 0 2.8 2.6 03/21/2006 23:40:00 11.3 1.7 15.3 7.2 11.2 1.8 15.3 4.9 11.1 1.7 15.3 6.8 336 7 333 165 2.9 0.1 3.3 2.6 03/21/2006 23:50:00 10.7 1.3 14.5 7.6 10.4 1.5 14.5 6.8 10.3 1.4 13.3 6.8 341 8 338 165 3.1 0 3.3 2.8 03/22/2006 00:00:00 9.1 1.7 13 5.7 9 1.8 13.3 3.4 9 1.7 13.3 5.3 337 8 343 165 3.4 0.1 3.5 2.8 03/22/2006 00:10:00 7.8 1.3 11.5 4.6 7.6 1.5 11.1 4.2 7.7 1.4 11.1 4.9 334 11 335 165 3.5 0 3.5 3.3 03/22/2006 00:20:00 8.8 1.7 13 5.3 8.6 1.7 13 5.3 8.5 1.5 12.2 5.3 328 9 332 165 3.5 0 3.5 3.3 03/22/2006 00:30:00 8.5 1.5 12.6 5.7 8.4 1.5 13 5.3 8.2 1.5 11.8 4.9 328 11 336 165 3.4 0 3.5 3.3 03/22/2006 00:40:00 8.5 1.7 13 4.9 8.2 1.8 13 5.3 7.8 1.4 11.5 4.6 334 12 339 165 3.2 0 3.5 3 03/22/2006 00:50:00 11.6 1.5 15.6 7.2 11.5 1.5 16.1 6.8 10.5 1.7 14.9 6.8 337 7 343 165 3.3 0 3.5 3.3 03/22/2006 01:00:00 11.6 1.7 16.1 6.5 11.3 2 16.8 6.1 10.7 1.7 16.4 5.7 339 11 348 165 3.3 0 3.5 3 03/22/2006 01:10:00 11.9 1.5 15.3 6.8 11.7 1.7 15.3 6.8 11 1.6 14.5 7.2 338 9 340 165 3.3 0 3.5 3.3 03/22/2006 01:20:00 11.8 1.9 16.4 8 11.4 1.7 17.2 7.6 11.5 1.7 16.4 8 338 10 351 165 3.4 0 3.8 3 03/22/2006 01:30:00 12.2 1.7 16.1 7.6 11.8 2 16.4 6.5 11.4 1.6 16.1 6.8 339 10 337 165 3.4 0.1 3.8 3 03/22/2006 01:40:00 12.8 1.9 17.6 6.1 12.5 2.1 17.6 6.5 11.7 2.2 17.6 5.3 338 9 339 165 3.7 0 4 3.5 03/22/2006 01:50:00 13.8 1.7 17.6 8.8 13.7 1.9 17.9 8.4 13.3 1.8 17.9 8.8 335 8 338 165 4 0 4.3 3.5 03/22/2006 02:00:00 12 2.3 19.5 6.8 11.9 2.4 20.2 6.8 11.4 2.2 17.6 7.2 332 11 343 165 3.9 0 4.3 3.5 03/22/2006 02:10:00 11.4 1.6 16.1 8 11.3 1.7 15.6 5.7 10.9 1.7 15.6 6.8 329 9 325 165 3.9 0.1 4.3 3.5 03/22/2006 02:20:00 12.7 1.9 17.6 8.8 12.4 2.1 18.3 7.2 12.1 1.7 16.8 8 333 12 333 165 4.1 0 4.3 3.8 03/22/2006 02:30:00 13.5 1.7 17.2 8.8 13.4 1.7 18.3 8.4 12.8 2 17.6 7.2 321 10 325 165 3.9 0 4.3 3.5 03/22/2006 02:40:00 14 1.7 20.6 8.4 13.9 1.7 21.4 8.8 13.6 1.7 19.9 8.4 322 9 317 165 3.6 0.1 3.8 3.3 03/22/2006 02:50:00 13.5 1.6 17.2 8.4 13.3 1.6 16.8 8 12.5 1.7 16.8 7.2 317 11 310 165 3.5 0 3.5 3.3 03/22/2006 03:00:00 15.2 1.5 19.5 11.5 15.1 1.5 19.5 11.5 13.6 1.9 20.2 8.4 312 9 328 165 3.4 0 3.5 3.3 03/22/2006 03:10:00 15.3 1.6 19.1 11.1 15.2 1.6 18.7 11.1 13.7 1.9 18.3 9.1 312 9 328 165 3.3 0 3.5 3 03/22/2006 03:20:00 15.5 1.7 19.5 10.3 15.4 1.7 19.9 9.9 14.8 1.7 19.9 8.4 320 10 330 165 3.5 0.1 4 3.3 03/22/2006 03:30:00 14.8 1.7 18.7 10.7 14.7 1.7 18.7 10.7 14.3 1.7 18.7 10.3 320 9 326 165 3.5 0.1 3.8 3.3 03/22/2006 03:40:00 15.4 1.7 19.5 11.5 15.3 1.7 19.5 11.1 14.2 1.9 19.9 9.1 315 9 314 165 3.6 0.1 3.8 3.3 03/22/2006 03:50:00 16.3 2.2 23.7 10.7 16.2 2.2 23.7 10.7 15.4 2.5 23.3 9.5 316 8 314 165 3.7 0.4 4.8 3.3 03/22/2006 04:00:00 16.2 1.7 20.6 10.7 16.1 1.7 20.6 11.1 14.9 2.2 20.2 8.8 313 9 320 165 4 0.1 4.5 3.5 03/22/2006 04:10:00 17.5 1.6 21 13.7 17.3 1.6 21 13.3 16.2 1.8 21.4 11.5 314 8 326 165 3.9 0.3 4.3 3.3 03/22/2006 04:20:00 17.6 1.6 21 13 17.6 1.6 21 13 16.7 1.8 21 12.2 316 10 313 165 3.6 0.2 4.3 3.3 03/22/2006 04:30:00 17.3 1.6 21.8 13.7 17.2 1.5 21.4 13.3 16.2 1.8 20.6 11.8 317 9 316 165 3.5 0.1 4 3 03/22/2006 04:40:00 17.3 1.7 22.1 12.6 17.2 1.7 21.8 12.6 16.6 1.7 21 11.8 321 12 312 165 3.7 0.3 4.3 3.3 03/22/2006 04:50:00 18.7 1.8 24 13.3 18.6 1.8 23.7 12.6 17.9 1.8 22.9 12.2 315 8 307 165 3.6 0.2 4 3.3 03/22/2006 05:00:00 18.1 1.8 22.9 13.7 17.9 1.8 22.9 13.3 16.8 1.7 22.6 11.8 314 8 320 165 3.6 0.1 3.8 3.3 03/22/2006 05:10:00 19.3 1.9 24.4 11.8 19.2 1.8 24 12.2 18.1 2.1 23.3 11.8 312 6 318 165 3.5 0.1 3.8 3.3 03/22/2006 05:20:00 19.2 1.6 23.7 14.9 19.1 1.6 23.3 14.5 17.3 2.1 22.9 11.5 310 8 302 165 3.2 0.2 3.5 2.8 03/22/2006 05:30:00 19 1.7 22.6 13.7 18.8 1.7 22.1 13.7 17.4 1.6 21.8 12.2 312 7 307 165 3.2 0.1 3.5 3 03/22/2006 05:40:00 19.7 1.8 24.4 11.8 19.5 1.7 24.4 11.8 17.6 2.3 22.6 11.1 309 7 303 165 3.3 0 3.5 3 03/22/2006 05:50:00 20.8 2 26.8 14.5 20.7 2 27.1 14.9 18.4 2.4 26.3 11.5 307 7 316 165 3.5 0 3.8 3.3 03/22/2006 06:00:00 20.9 2.1 26.8 15.6 20.8 2.1 26 15.6 18 2.2 23.7 11.8 306 8 298 165 3.5 0 3.8 3.3 03/22/2006 06:10:00 21.7 1.8 26.8 15.6 21.5 1.7 26.3 15.6 18.3 2 24.4 13 305 6 301 165 3.5 0.1 3.8 3.3 03/22/2006 06:20:00 21.6 1.6 25.6 16.8 21.5 1.5 25.2 16.8 18 2 23.7 12.6 304 6 300 165 3.5 0 4 3.3 03/22/2006 06:30:00 22.2 1.7 27.5 16.4 22 1.7 26.8 16.8 18.4 2.2 24.4 13 304 7 300 165 3.4 0 3.8 3.3 03/22/2006 06:40:00 21.7 2.4 26.8 14.5 21.5 2.3 26 14.1 17.9 2.1 24.4 11.5 304 6 299 165 3.3 0 3.5 3 03/22/2006 06:50:00 22.3 2 26.3 15.6 22.2 2 26.8 16.1 18.9 2.2 26.8 13.7 304 5 305 165 3.3 0 3.5 3 03/22/2006 07:00:00 22.7 1.9 27.5 17.6 22.6 1.9 27.5 17.6 19.2 2.2 26.8 13.3 304 5 312 165 3.3 0 3.5 3 03/22/2006 07:10:00 22.9 1.8 27.9 17.6 22.8 1.7 27.1 17.2 18.5 1.9 23.7 13.3 302 5 295 165 3.3 0 3.5 3 03/22/2006 07:20:00 22.5 2 27.1 16.8 22.4 2 26.3 17.2 18.3 2.1 24 13.7 303 5 302 165 3.3 0 3.5 3.3 03/22/2006 07:30:00 22.7 1.6 26.3 17.6 22.6 1.6 26.8 17.2 18.2 1.9 24.8 13.3 303 5 301 165 3.3 0 3.5 3.3 03/22/2006 07:40:00 22 1.7 25.6 15.6 21.9 1.7 25.2 16.1 17.8 1.9 22.9 11.8 303 5 292 165 3.2 0 3.5 3 03/22/2006 07:50:00 21.4 1.5 25.2 17.6 21.4 1.5 25.2 17.9 17.8 1.7 22.1 13.3 304 5 306 165 3.2 0 3.3 3 03/22/2006 08:00:00 20.6 1.9 25.2 15.6 20.5 1.9 24.8 15.3 17.5 1.7 22.1 12.6 305 5 300 165 3.3 0 3.5 3.3 03/22/2006 08:10:00 19.4 2.4 25.6 14.1 19.2 2.3 25.6 13.7 16.6 2.1 24 10.7 306 5 313 165 3.4 0 3.5 3.3 03/22/2006 08:20:00 16.8 2.2 21.4 11.8 16.5 2.1 20.6 11.1 13.9 2.1 19.5 9.1 305 7 302 165 3.5 0 3.8 3.5 03/22/2006 08:30:00 16.9 1.8 21 12.2 16.8 1.7 21 12.2 13.9 1.8 19.5 9.1 306 6 302 165 3.7 0.1 4 3.5 03/22/2006 08:40:00 19.2 1.6 22.6 15.6 19 1.5 23.3 15.3 15.3 2.1 22.9 9.5 303 6 302 165 3.6 0 3.8 3.5 03/22/2006 08:50:00 19.7 1.7 24 14.9 19.6 1.7 24 14.9 15.6 1.9 21 10.3 304 5 306 165 4 0.2 4.5 3.5 03/22/2006 09:00:00 19.9 1.7 24 15.3 19.8 1.7 23.7 15.3 15.8 1.6 20.2 10.7 303 5 296 165 3.7 0 3.8 3.5 03/22/2006 09:10:00 18.6 1.8 24.4 13.3 18.5 1.8 24.4 13.7 15.7 1.8 21.8 9.9 306 6 305 165 3.8 0 4 3.5 03/22/2006 09:20:00 18.1 1.9 22.9 13 18 1.8 22.9 12.2 15 1.7 20.2 11.5 305 7 311 165 4 0 4.3 3.8 03/22/2006 09:30:00 20.1 1.7 24.4 14.5 20 1.6 23.7 14.5 15.6 2 22.1 10.3 301 6 292 165 3.8 0 4.3 3.5 03/22/2006 09:40:00 18.9 1.7 22.9 13.7 18.8 1.7 22.9 13.3 14.7 1.6 19.1 11.1 303 6 300 165 4.2 0.1 4.8 3.8 03/22/2006 09:50:00 15 2.4 21.8 8.4 14.9 2.3 21.8 8.8 11.6 2.3 19.1 4.9 302 7 300 165 4.8 0.3 5.7 4.5 03/22/2006 10:00:00 8.4 2.6 13.3 1.1 8.3 2.6 13.3 0.7 5.6 2.3 11.1 0.4 301 20 304 165 6.2 0.4 6.7 5.2 03/22/2006 10:10:00 5.2 2.1 10.7 0.7 5.2 2.2 10.7 0.4 3.8 1.8 9.5 0.4 288 53 288 165 6.7 0.2 7.5 6.2 03/22/2006 10:20:00 6.6 1.8 10.7 2.3 6.6 1.8 10.7 2.3 5.5 1.9 10.7 0.7 292 15 278 165 6.2 0.4 7.5 5.2 03/22/2006 10:30:00 12.1 2.2 16.8 5.7 12.1 2.2 16.8 5.3 11.1 2 16.8 5.7 286 8 287 165 4.8 0.3 5.5 4.3 03/22/2006 10:40:00 12.6 2.4 16.8 6.8 12.7 2.3 17.2 6.8 12.1 2.3 17.2 6.1 283 8 294 165 4.3 0.1 4.5 4.3 03/22/2006 10:50:00 14.9 1.4 19.1 11.5 15 1.4 18.7 11.5 14.1 1.6 18.7 9.9 283 5 280 165 4.1 0 4.3 3.8 03/22/2006 11:00:00 14.4 1.7 18.3 9.9 14.4 1.7 18.3 9.9 11.8 1.9 16.8 7.2 292 7 289 165 4.1 0 4.3 3.8 03/22/2006 11:10:00 16 1.3 19.5 12.6 16 1.3 19.5 12.6 11.7 1.6 16.4 8.4 301 5 297 165 4.2 0 4.5 4 03/22/2006 11:20:00 15.4 1.5 19.5 10.7 15.3 1.5 19.5 10.7 11.8 1.7 18.3 8 302 5 297 165 4.3 0 4.5 4.3 03/22/2006 11:30:00 15.8 1.6 18.7 10.3 15.8 1.6 19.1 10.3 11.9 1.6 16.4 8.4 302 6 301 165 4.4 0 4.5 4.3 03/22/2006 11:40:00 15.4 1.5 19.1 10.7 15.4 1.6 19.1 10.7 11 1.4 16.1 7.2 299 5 299 165 4.3 0 4.5 4.3 03/22/2006 11:50:00 14.9 1.4 17.9 10.7 14.8 1.4 17.9 10.3 11.2 1.5 16.8 8 300 6 300 165 4.4 0 4.5 4.3 03/22/2006 12:00:00 14.9 1.5 18.7 10.7 14.9 1.6 18.7 11.1 11.7 1.5 16.1 7.6 300 6 302 165 4.4 0 4.8 4.3 03/22/2006 12:10:00 14.4 1.7 18.3 9.9 14.3 1.7 19.1 9.5 11.5 1.7 17.9 7.2 302 7 303 165 4.6 0 4.8 4.3 03/22/2006 12:20:00 15.4 1.6 18.7 9.9 15.3 1.6 18.3 9.9 11.7 1.3 16.8 8.4 299 7 302 165 4.4 0 4.8 3.8 03/22/2006 12:30:00 15.1 1.5 18.7 10.7 15 1.5 18.7 10.3 11.1 1.2 16.1 8.4 298 6 281 165 4.4 0 4.8 4.3 03/22/2006 12:40:00 14.6 1.7 17.9 9.9 14.5 1.7 17.9 9.5 10.6 1.3 16.1 6.8 298 6 295 165 4.4 0 4.8 4.3 03/22/2006 12:50:00 14.8 1.6 17.6 10.3 14.7 1.6 17.6 9.5 11.5 1.7 17.2 7.6 294 5 288 165 4.3 0 4.5 4 03/22/2006 13:00:00 13.6 1.7 17.6 8.8 13.6 1.7 17.6 8.8 10.6 1.7 15.6 6.5 295 7 288 165 4.4 0 4.8 4.3 03/22/2006 13:10:00 13.5 1.7 18.7 7.6 13.5 1.8 18.3 7.6 10.4 1.6 14.9 6.5 296 7 296 165 4.4 0 4.8 3.5 03/22/2006 13:20:00 12.2 2.2 17.9 7.6 12.2 2.3 18.3 7.6 10.4 2.5 17.6 5.7 294 9 271 165 4.6 0 4.8 4.3 03/22/2006 13:30:00 10.6 1.9 15.6 6.1 10.6 1.9 16.1 5.7 9.1 2.1 15.3 4.6 292 7 282 165 4.6 0.1 5 4.3 03/22/2006 13:40:00 9.2 1.5 13 5.7 9.2 1.5 13 5.7 8.5 1.7 13.7 4.9 284 9 264 165 4.6 0 5 4.3 03/22/2006 13:50:00 7.5 1.5 12.2 3.8 7.6 1.5 11.8 3.8 7 1.6 12.2 4.2 291 13 261 165 4.8 0.3 5.5 4.3 03/22/2006 14:00:00 7.6 2 11.5 3 7.6 2.1 11.5 2.6 6.7 1.8 10.7 3 291 10 282 165 4.8 0.3 5.5 4.3 03/22/2006 14:10:00 7.3 1.2 10.7 4.9 7.2 1.2 10.7 4.9 6.1 1.3 11.1 2.6 295 11 291 165 5.4 0.1 6.2 5 03/22/2006 14:20:00 8.6 1.3 11.8 4.9 8.5 1.2 11.5 4.9 7 1 10.3 4.2 302 8 298 165 5 0 5.5 4.8 03/22/2006 14:30:00 6.8 1.2 9.5 3.8 6.7 1.2 9.1 3.8 5.5 0.9 7.6 3 303 11 303 165 5.2 0.1 5.7 5 03/22/2006 14:40:00 8.3 1.4 12.2 4.9 8.2 1.4 11.8 4.9 6.9 1.3 10.3 3.8 302 9 302 165 5.1 0.1 5.5 4.8 03/22/2006 14:50:00 9.9 1.1 13 6.5 9.9 1.1 13 7.2 7.5 1 10.7 4.9 300 6 297 165 4.4 0.2 5 4 03/22/2006 15:00:00 11.2 1.1 14.5 8 11.2 1 14.1 8 8.2 1 11.5 6.1 299 5 302 165 4 0 4.3 3.8 03/22/2006 15:10:00 10.4 1.2 14.5 7.2 10.4 1.2 14.1 7.2 8.5 1.3 14.5 5.7 304 7 312 165 4 0 4.3 3.8 03/22/2006 15:20:00 9.6 1.2 12.6 6.1 9.6 1.2 12.2 6.1 8.2 1.3 11.8 5.3 308 8 306 165 4.3 0.2 4.8 4 03/22/2006 15:30:00 8.7 1 12.2 6.1 8.7 1 11.5 5.7 7.2 1 10.3 4.9 299 8 296 165 4.4 0 4.8 4.3 03/22/2006 15:40:00 9.9 0.7 11.8 7.6 9.8 0.7 11.5 7.6 8.7 1.1 11.8 5.3 309 5 312 165 4.4 0 4.8 4.3 03/22/2006 15:50:00 8.9 0.6 10.7 7.2 8.8 0.6 10.3 7.6 7.9 0.9 10.3 5.7 309 5 301 165 4.5 0 4.8 4.3 03/22/2006 16:00:00 8.3 1 9.9 5.3 8.2 1.1 9.9 4.2 7.2 0.8 9.5 5.3 312 13 305 165 4.3 0.1 4.8 4.3 03/22/2006 16:10:00 6.1 0.9 8 3.8 6 1 8 3 5.6 0.8 8 3 320 19 306 165 5.1 0.1 5.2 4.5 03/22/2006 16:20:00 6.1 0.9 8 3.8 5.2 1.4 8.8 2.3 6.2 0.9 8.8 3.8 349 10 346 165 5.2 0 5.5 5 03/22/2006 16:30:00 5.9 0.7 8 4.2 4.8 1 7.2 2.6 5.8 0.6 7.6 3.8 350 7 346 165 5.5 0 5.7 5.2 03/22/2006 16:40:00 6.1 0.7 8 4.2 4.6 1.5 8.4 2.3 6 0.7 7.6 4.2 357 8 346 165 5.5 0 5.7 5.2 03/22/2006 16:50:00 6.7 0.7 8.8 5.3 5.9 1.1 8.4 3 6.6 0.7 8 4.2 347 9 351 165 5.1 0 5.5 4.8 03/22/2006 17:00:00 7 0.7 8.8 4.9 6.3 1 8.8 3.8 7.1 0.8 9.5 5.3 345 8 351 165 4.8 0.1 5 4.5 03/22/2006 17:10:00 7.2 1 9.5 4.2 6.6 1.3 9.5 3 7.3 1.1 9.5 3.8 344 8 339 165 4.3 0.1 4.8 4 03/22/2006 17:20:00 7.1 0.8 9.5 4.9 6.9 1 9.1 3.8 7.1 0.8 9.1 4.9 341 7 340 165 4.2 0.1 4.5 4 03/22/2006 17:30:00 6.4 1.1 9.5 4.2 6 1.3 9.1 2.3 6.5 1.2 9.9 4.2 337 11 350 165 3.9 0.1 4.3 3.3 03/22/2006 17:40:00 5.6 0.6 7.6 4.2 5.3 0.9 7.6 2.6 5.6 0.6 7.6 4.2 340 11 334 165 4 0.2 4.3 3.3 03/22/2006 17:50:00 6.6 1.2 9.5 4.6 6.3 1.3 9.9 3 6.4 1.5 9.9 3.4 338 11 334 165 3.8 0.2 4.3 3.3 03/22/2006 18:00:00 6.8 0.9 8.8 4.6 6.6 1.2 9.5 3 6.9 0.9 9.1 4.2 335 11 338 165 3.3 0.2 3.8 2.8 03/22/2006 18:10:00 6.8 0.8 8.8 4.9 6.7 1 8.8 4.6 6.7 0.8 9.1 4.2 336 11 347 165 2.8 0 3.3 2.6 03/22/2006 18:20:00 7 1.1 10.3 4.2 6.2 1 8.8 2.6 7 1.1 9.9 4.2 343 12 354 165 2.6 0.1 2.8 2.1 03/22/2006 18:30:00 7.1 1.1 9.9 4.2 6.4 1.4 10.3 2.6 7.2 1.1 9.9 4.9 346 10 351 165 2.2 0.1 2.6 1.6 03/22/2006 18:40:00 8.3 1.2 11.8 5.7 8 1.3 11.5 4.9 8.4 1.3 11.5 5.7 338 11 324 165 2 0.1 2.3 1.6 03/22/2006 18:50:00 7.8 1.1 10.3 4.9 7.3 1.4 10.3 3 7.7 1.2 11.1 4.2 342 11 340 165 1.8 0 1.8 1.4 03/22/2006 19:00:00 8 0.9 10.7 6.5 7.4 1.2 10.3 3.8 7.9 0.8 10.3 6.1 345 9 352 165 1.5 0.2 1.8 1.1 03/22/2006 19:10:00 8.7 1.6 12.6 5.7 8.6 1.6 13.3 5.7 8.7 1.7 13.7 5.3 340 9 336 165 1 0 1.4 0.9 03/22/2006 19:20:00 7.2 0.7 9.1 5.7 7.2 0.8 9.5 3.8 7.2 0.8 9.1 4.9 339 7 343 165 0.8 0 0.9 0.7 03/22/2006 19:30:00 6.6 0.7 8.8 4.9 6.4 0.9 9.5 3.8 6.7 0.9 9.9 4.6 336 11 328 165 0.8 0 0.9 0.7 03/22/2006 19:40:00 7.6 1.2 10.3 4.6 7.5 1.2 10.3 4.2 7.5 1.2 10.3 4.6 334 10 332 165 0.8 0.1 1.1 0.7 03/22/2006 19:50:00 9.2 1.2 13.3 6.1 9.1 1.2 13.3 5.3 9.2 1.1 12.2 5.3 333 9 346 165 1 0 1.4 0.9 03/22/2006 20:00:00 8.6 1.1 12.2 5.7 8.3 1.6 11.8 3.4 8.7 1.2 12.2 5.7 340 9 331 165 0.9 0.1 1.1 0.9 03/22/2006 20:10:00 8.4 1.5 11.8 6.1 8.2 1.6 12.2 3.4 8.6 1.4 12.2 6.1 342 7 333 165 0.8 0 0.9 0.7 03/22/2006 20:20:00 8.1 0.9 10.7 5.7 7.8 1.2 10.3 3.8 8 1 10.7 4.6 334 12 350 165 0.8 0 1.1 0.7 03/22/2006 20:30:00 8.2 0.9 10.3 5.7 7.9 1.3 11.1 3.4 8.3 1 10.3 5.7 339 10 336 165 0.7 0 0.9 0.7 03/22/2006 20:40:00 6.4 0.9 9.1 4.2 6.3 1 9.1 3.8 6.5 1 9.1 4.2 332 12 327 165 0.8 0 0.9 0.7 03/22/2006 20:50:00 6.2 1.2 9.5 4.2 6.1 1.2 9.5 3.8 6.4 1.2 9.5 4.2 329 10 341 165 0.8 0 0.9 0.7 03/22/2006 21:00:00 7 1.2 11.1 4.6 6.9 1.2 11.5 4.6 7 1.3 11.1 3.4 327 11 334 165 0.8 0 1.1 0.7 03/22/2006 21:10:00 6.9 0.8 9.1 4.6 6.7 0.8 9.1 3.4 6.9 0.9 9.9 4.9 329 9 316 165 0.8 0 0.9 0.7 03/22/2006 21:20:00 7.2 0.9 9.5 4.9 7.1 0.9 9.5 4.6 7.1 0.9 9.5 4.9 322 9 328 165 0.8 0 0.9 0.7 03/22/2006 21:30:00 6.1 0.8 8.4 4.6 6 0.8 8.8 3.8 6 0.9 8.8 3.8 324 10 323 165 0.6 0 0.9 0.4 03/22/2006 21:40:00 6.7 0.8 9.1 4.6 6.6 0.9 9.1 4.6 6.8 0.8 9.1 4.9 322 8 338 165 0.7 0 0.9 0.7 03/22/2006 21:50:00 7.1 1.2 10.3 5.3 7 1.3 10.3 4.9 7.1 1.2 10.3 4.9 328 8 336 165 0.5 0 0.7 0.4 03/22/2006 22:00:00 7.3 0.9 9.5 4.9 7.2 0.9 9.9 4.9 7.2 1 9.9 4.9 327 9 323 165 0.5 0 0.9 0.2 03/22/2006 22:10:00 7.4 1 10.3 5.3 7.3 1 10.7 4.9 7.3 0.9 9.5 5.3 327 10 339 165 0.4 0 0.7 0.2 03/22/2006 22:20:00 7.2 1 9.9 5.3 7 1 9.9 4.9 7.1 1 9.9 4.9 321 8 316 165 0.1 0 0.7 -0.1 03/22/2006 22:30:00 7 1 9.5 4.9 6.8 1 9.1 4.6 6.6 1 9.1 3.8 319 10 309 165 0 0 0.2 -0.1 03/22/2006 22:40:00 6.3 0.7 8 4.2 6.2 0.7 7.6 3.8 6.1 0.7 8 4.6 324 11 307 165 0.1 0.1 0.4 -0.1 03/22/2006 22:50:00 4.8 0.6 6.5 3.4 4.6 0.6 6.5 3.4 4.7 0.5 6.5 3.4 327 9 315 165 0.2 0 0.7 0.2 03/22/2006 23:00:00 4.8 0.6 6.5 3.4 4.4 0.9 6.8 1.9 5 0.5 6.5 3.8 339 12 340 165 0.6 0.1 0.9 0.2 03/22/2006 23:10:00 5.4 0.6 7.2 4.2 5 0.8 7.2 2.3 5.6 0.7 8 4.2 338 11 341 165 0.5 0 0.9 0.2 03/22/2006 23:20:00 5.4 1 7.6 3 5.3 1 8 3 5.5 0.9 8 3.4 328 10 336 165 0.5 0 0.7 0.2 03/22/2006 23:30:00 5.6 0.8 7.6 4.2 5.5 0.8 7.6 3.8 5.6 0.8 8 3.8 330 8 325 165 0.4 0 0.7 0.2 03/22/2006 23:40:00 5.6 0.7 7.2 4.2 5.5 0.7 7.2 3.8 5.7 0.8 7.6 4.2 335 8 334 165 0.4 0.1 0.7 0.2 03/22/2006 23:50:00 6.4 0.7 8 4.9 6.4 0.7 8.4 4.6 6.4 0.7 8 4.9 339 5 341 165 0.3 0 0.7 0.2 03/23/2006 00:00:00 6.2 0.5 7.6 4.6 6.1 0.6 7.6 4.6 6.2 0.5 7.6 4.9 334 7 333 165 0.2 0.1 0.4 0.2 03/23/2006 00:10:00 5.6 0.5 7.2 4.6 5.6 0.5 7.2 3.8 5.7 0.4 6.8 4.6 329 8 338 165 -0.1 0.2 0.2 -0.3 03/23/2006 00:20:00 5.6 0.6 7.2 4.6 5.5 0.6 7.2 4.2 5.6 0.5 7.2 4.2 320 8 319 165 -0.2 0 -0.1 -0.5 03/23/2006 00:30:00 5.9 0.5 7.2 4.6 5.8 0.5 7.2 4.6 5.6 0.6 7.6 3.8 316 8 311 165 -0.2 0 0.2 -0.3 03/23/2006 00:40:00 5.7 0.5 7.2 4.6 5.6 0.5 6.8 4.6 5.6 0.4 7.2 4.2 315 8 318 165 0.2 0.1 0.7 -0.1 03/23/2006 00:50:00 5.3 0.5 6.8 3.8 5.2 0.5 6.8 3.4 5.1 0.6 6.8 3.4 315 9 332 165 0.2 0 0.2 -0.1 03/23/2006 01:00:00 5.8 1 8.4 2.6 5.7 1 8.8 3 5.7 1.2 9.1 3.4 319 17 328 165 0.1 0.2 0.9 -0.1 03/23/2006 01:10:00 6 0.7 7.6 3.4 5.9 0.8 8 3.4 5.9 0.7 8 3.8 330 9 320 165 0.4 0.2 0.9 0.2 03/23/2006 01:20:00 5.8 0.6 8 4.6 5.7 0.6 8 4.6 5.8 0.6 8.4 4.6 325 7 331 165 0.2 0.1 0.7 -0.1 03/23/2006 01:30:00 5.2 0.4 6.5 3.8 5.1 0.5 6.5 3.8 4.8 0.6 6.5 3 310 10 327 165 0.2 0.1 0.7 -0.1 03/23/2006 01:40:00 6 0.5 7.2 4.6 5.9 0.4 6.8 4.9 5.5 0.8 7.2 3.4 310 8 304 165 -0.1 0.1 0.2 -0.3 03/23/2006 01:50:00 5.7 0.6 6.8 4.2 5.6 0.5 6.8 4.2 5.7 0.7 7.2 3.8 321 7 318 165 0.1 0.1 0.7 -0.3 03/23/2006 02:00:00 5.4 0.8 7.2 3 5.3 0.8 7.6 3 5.3 0.8 6.8 3 326 11 342 165 0.3 0.1 0.7 0.2 03/23/2006 02:10:00 4.9 0.7 6.8 3.4 4.8 0.7 6.5 3 4.5 0.6 6.5 3.4 312 10 314 165 0.5 0 0.9 0.4 03/23/2006 02:20:00 5.7 0.8 7.6 3.8 5.7 0.8 7.6 3.8 5 0.7 6.8 3.4 302 8 301 165 0.4 0.1 0.7 0.2 03/23/2006 02:30:00 5.6 0.6 7.2 3.8 5.6 0.6 7.2 3.8 5.2 0.6 6.5 3.4 309 9 308 165 0.3 0 0.7 0.2 03/23/2006 02:40:00 4.9 0.5 6.1 3.4 4.7 0.5 6.1 3 4.7 0.6 6.5 3.4 317 12 328 165 0.4 0 0.7 0.2 03/23/2006 02:50:00 4.1 0.6 5.7 2.3 4 0.6 5.7 2.3 3.8 0.6 5.3 2.3 309 11 300 165 0.7 0 0.9 0.4 03/23/2006 03:00:00 4.9 0.7 6.8 3.4 4.8 0.7 6.8 3.4 4.3 0.6 6.1 3 307 7 302 165 0.2 0 0.7 0.2 03/23/2006 03:10:00 5.1 0.5 6.5 3.4 5 0.5 6.1 3.4 4.5 0.6 6.1 3 307 5 305 165 0.5 0 0.7 0.2 03/23/2006 03:20:00 4.7 0.5 6.1 3.8 4.7 0.5 6.1 3.8 4.2 0.5 5.3 2.6 305 6 295 165 0.6 0 0.9 0.2 03/23/2006 03:30:00 5.3 0.5 6.8 4.2 5.2 0.5 6.8 4.2 4.2 0.5 5.7 3 301 5 302 165 0.6 0 0.9 0.4 03/23/2006 03:40:00 5 0.5 6.1 3.8 5 0.5 6.1 3.8 4.1 0.5 5.3 2.6 301 5 304 165 0.5 0 0.7 0.2 03/23/2006 03:50:00 4.2 0.6 5.7 3 4.2 0.6 5.7 2.6 3.8 0.5 5.3 2.6 304 6 297 165 0.7 0 0.9 0.2 03/23/2006 04:00:00 4.6 0.5 5.7 3.4 4.5 0.5 5.7 3.4 3.9 0.5 4.9 2.6 301 6 293 165 0.7 0.1 0.9 0.4 03/23/2006 04:10:00 3.7 0.6 5.3 2.3 3.7 0.6 5.3 1.9 3.2 0.5 4.9 1.9 298 4 296 165 0.8 0 1.1 0.7 03/23/2006 04:20:00 1.7 0.5 3 0.7 1.4 0.6 2.6 0.4 1.8 0.5 3 0.7 301 6 299 165 1.1 0.1 1.4 0.9 03/23/2006 04:30:00 1.4 0.3 2.3 0.4 1.1 0.4 1.9 0.4 1.6 0.3 2.6 0.7 302 7 297 165 1.4 0 1.6 1.1 03/23/2006 04:40:00 1.2 0.5 2.6 0.4 0.9 0.5 2.6 0.4 1.6 0.3 2.3 0.7 313 5 302 165 1.1 0 1.4 0.9 03/23/2006 04:50:00 1.7 0.5 3 0.7 1.4 0.5 2.6 0.4 1.8 0.3 2.6 1.1 297 5 295 165 1.3 0.1 1.6 0.9 03/23/2006 05:00:00 1.6 0.6 3 0.7 1.4 0.6 2.6 0.4 1.7 0.5 3 0.7 288 8 286 165 1.4 0 1.6 1.1 03/23/2006 05:10:00 1.8 0.5 2.6 0.4 1.7 0.6 2.6 0.4 1.8 0.4 2.6 1.1 283 8 294 165 1.2 0.1 1.6 0.9 03/23/2006 05:20:00 2.3 1.2 4.9 0.4 2.2 1.3 4.6 0.4 2.4 1 4.6 1.1 278 9 284 165 1.7 0.1 1.8 1.4 03/23/2006 05:30:00 4.5 0.6 6.1 3 4.5 0.7 6.1 3 3.8 0.7 5.7 2.3 296 7 292 165 1.2 0 1.6 0.9 03/23/2006 05:40:00 4.9 0.9 6.5 3 4.8 0.9 6.5 3 3.9 0.7 6.1 2.3 293 4 296 165 1.2 0.1 1.6 0.9 03/23/2006 05:50:00 2.8 0.8 4.2 0.4 2.7 0.9 4.2 0.4 2.4 0.6 3.8 0.4 289 16 296 165 1.8 0.1 2.1 1.6 03/23/2006 06:00:00 1.1 0.5 1.9 0.4 1.1 0.5 1.9 0.4 1.8 0.4 2.6 0.4 268 22 286 165 2.3 0.1 2.6 2.1 03/23/2006 06:10:00 1.9 0.5 3.4 1.1 1.9 0.5 3 1.1 2 0.5 3 1.1 301 9 317 165 1.9 0.2 2.3 1.4 03/23/2006 06:20:00 1.1 0.4 2.3 0.4 0.9 0.5 2.3 0.4 1.6 0.4 2.6 0.4 278 24 310 165 1.4 0 1.6 1.4 03/23/2006 06:30:00 1 0.3 1.9 0.4 0.8 0.4 1.5 0.4 1.4 0.3 1.9 0.4 245 9 251 165 1.5 0.1 1.6 1.4 03/23/2006 06:40:00 1 0.3 1.5 0.4 0.6 0.3 1.5 0.4 1.5 0.3 2.3 0.7 227 10 229 165 2 0.4 2.8 1.4 03/23/2006 06:50:00 1.3 0.4 1.9 0.4 0.8 0.5 1.9 0.4 1.6 0.5 2.3 0.4 200 8 192 165 2.2 0.2 2.8 1.8 03/23/2006 07:00:00 1 0.5 1.9 0.4 0.8 0.4 1.5 0.4 1.4 0.2 1.9 1.1 210 5 205 165 2.4 0.2 2.8 1.8 03/23/2006 07:10:00 0.9 0.4 1.5 0.4 0.7 0.3 1.5 0.4 1.3 0.2 1.9 0.7 207 7 210 165 3 0.1 3.3 2.6 03/23/2006 07:20:00 1.2 0.3 1.9 0.4 1.1 0.3 1.9 0.4 1.5 0.4 2.3 0.7 244 18 227 165 3.3 0 3.5 3 03/23/2006 07:30:00 1 0.5 1.9 0.4 0.9 0.5 1.9 0.4 1.4 0.4 2.3 0.4 247 13 244 165 3.5 0.1 3.8 3 03/23/2006 07:40:00 1.2 0.4 2.3 0.4 1 0.5 2.3 0.4 1.5 0.3 2.3 0.7 300 18 284 165 3.2 0 3.5 3 03/23/2006 07:50:00 1.4 0.3 1.9 0.4 1.3 0.3 2.3 0.4 1.6 0.2 2.3 1.1 296 9 287 165 3.6 0.1 3.8 3.3 03/23/2006 08:00:00 0.6 0.4 1.5 0.4 0.4 0.1 1.1 0.4 0.7 0.5 1.9 0.4 237 49 287 165 4.5 0.4 5 3.8 03/23/2006 08:10:00 0.6 0.4 1.9 0.4 0.4 0.1 1.1 0.4 0.5 0.3 1.5 0.4 173 33 128 165 5.1 0.3 5.7 4.5 03/23/2006 08:20:00 0.7 0.5 1.9 0.4 0.4 0.1 0.7 0.4 0.5 0.4 1.9 0.4 214 51 277 165 5.2 0.6 6 4.5 03/23/2006 08:30:00 0.6 0.4 1.9 0.4 0.4 0.1 1.1 0.4 0.6 0.3 1.5 0.4 225 38 279 165 5.9 0.2 6.2 5.5 03/23/2006 08:40:00 0.9 0.4 1.9 0.4 0.7 0.4 1.5 0.4 0.5 0.3 1.1 0.4 255 35 277 165 5.6 0.3 6.2 5 03/23/2006 08:50:00 0.6 0.3 1.5 0.4 0.5 0.2 1.1 0.4 0.6 0.3 1.5 0.4 217 30 210 165 5.2 0.1 5.7 5 03/23/2006 09:00:00 0.4 0.2 1.1 0.4 0.4 0.1 0.7 0.4 0.4 0.2 1.1 0.4 218 1 218 165 4.6 0.1 5 4.3 03/23/2006 09:10:00 0.9 0.4 1.9 0.4 0.9 0.4 1.5 0.4 1 0.5 1.9 0.4 228 10 234 165 4.1 0.1 4.5 3.8 03/23/2006 09:20:00 1 0.5 2.3 0.4 0.9 0.5 2.3 0.4 1 0.3 1.9 0.4 227 23 235 165 4.5 0.3 5.2 4 03/23/2006 09:30:00 0.9 0.5 2.3 0.4 0.9 0.5 2.3 0.4 1.1 0.5 2.6 0.4 226 22 235 165 5 0 5.2 4.8 03/23/2006 09:40:00 0.9 0.4 1.5 0.4 0.8 0.4 1.5 0.4 0.9 0.3 1.5 0.4 225 45 267 165 4.8 0.4 5.7 4.3 03/23/2006 09:50:00 1 0.5 2.6 0.4 1 0.6 2.6 0.4 1 0.5 2.3 0.4 272 20 266 165 4.1 0 4.3 3.8 03/23/2006 10:00:00 1.3 0.5 2.6 0.4 1.5 0.5 2.6 0.4 1.4 0.5 2.3 0.4 265 12 276 165 4.1 0.2 4.8 3.5 03/23/2006 10:10:00 1.2 0.6 3 0.4 1.3 0.7 2.6 0.4 1.1 0.6 2.6 0.4 260 28 276 165 5.5 0.3 6 4.8 03/23/2006 10:20:00 2.1 0.6 3.4 0.4 2 0.6 3.8 0.4 2.1 0.6 3.8 0.4 160 16 150 165 5.4 0.3 6.2 5 03/23/2006 10:30:00 2.2 0.4 3.4 1.1 2.2 0.4 3.4 1.1 2.3 0.5 3.8 1.1 145 17 137 165 5.1 0.1 5.5 4.8 03/23/2006 10:40:00 1.3 0.7 3.4 0.4 1.3 0.7 3.4 0.4 1.3 0.7 3.4 0.4 150 26 129 165 5.6 0.4 6.2 5.2 03/23/2006 10:50:00 1 0.6 3 0.4 1 0.6 3 0.4 0.9 0.6 2.6 0.4 153 41 90 165 6.5 0.2 7.3 6.2 03/23/2006 11:00:00 1.5 0.7 3 0.4 1.5 0.7 3 0.4 1.6 0.6 3 0.4 131 29 139 165 6.4 0.2 7 6 03/23/2006 11:10:00 1.5 0.7 3 0.4 1.4 0.7 3.4 0.4 1.4 0.7 3 0.4 224 30 225 165 6 0.3 6.7 5.5 03/23/2006 11:20:00 1.3 0.4 2.3 0.4 1.7 0.5 2.6 0.4 1.7 0.6 2.6 0.4 260 7 268 165 5.2 0.2 5.7 4.8 03/23/2006 11:30:00 1 0.6 2.6 0.4 1.2 0.6 2.6 0.4 1.1 0.6 2.6 0.4 248 19 250 165 5.6 0.1 6.2 5 03/23/2006 11:40:00 1.3 0.4 2.3 0.4 1.4 0.4 2.3 0.4 1.3 0.4 2.3 0.4 243 15 238 165 5.7 0.2 6.2 5.5 03/23/2006 11:50:00 1.6 0.5 2.6 0.4 1.7 0.4 2.6 0.7 1.5 0.5 2.6 0.4 249 21 224 165 6.4 0 6.7 6.2 03/23/2006 12:00:00 1.3 0.6 2.6 0.4 1.4 0.5 2.6 0.4 1.4 0.5 2.6 0.4 228 26 221 165 6.4 0 6.7 6 03/23/2006 12:10:00 1.6 0.7 3.4 0.4 1.7 0.7 3.4 0.4 1.5 0.8 3.8 0.4 207 58 292 165 6.4 0.2 7 6 03/23/2006 12:20:00 0.6 0.4 2.6 0.4 0.6 0.4 2.3 0.4 0.6 0.5 1.9 0.4 232 69 175 165 7.3 0.2 8 7 03/23/2006 12:30:00 0.6 0.4 2.3 0.4 0.7 0.4 2.3 0.4 0.6 0.4 1.9 0.4 151 35 89 165 8.2 0.6 9.3 7.3 03/23/2006 12:40:00 1.7 1.1 4.2 0.4 1.7 1.1 4.6 0.4 1.7 1.2 3.8 0.4 152 13 150 165 9 1 10.3 7 03/23/2006 12:50:00 2.9 0.6 4.6 1.5 2.8 0.6 4.6 1.1 2.9 0.6 4.6 1.5 157 13 147 165 5.6 0.4 7 5.2 03/23/2006 13:00:00 1.4 0.6 2.6 0.4 1.4 0.6 3 0.4 1.5 0.7 3 0.4 163 17 146 165 6.1 0.3 6.7 5.5 03/23/2006 13:10:00 1.3 1 3.8 0.4 1.4 1 3.8 0.4 1.4 1 3.4 0.4 181 33 165 165 6.8 0.2 7.3 6.2 03/23/2006 13:20:00 1.8 0.6 3 0.4 1.8 0.6 3.4 0.4 1.8 0.6 3.4 0.4 156 17 147 165 6.8 0.1 7 6.5 03/23/2006 13:30:00 2.3 0.6 4.2 0.7 2.3 0.6 3.8 0.7 2.3 0.5 3.4 0.7 157 12 165 165 6.5 0.3 7.3 6 03/23/2006 13:40:00 2.1 0.7 3.8 0.7 2.1 0.7 3.4 0.4 2.1 0.7 3.8 0.4 155 14 163 165 6.3 0.2 7 6 03/23/2006 13:50:00 1.1 0.6 2.6 0.4 1.1 0.6 3 0.4 1.1 0.5 2.6 0.4 301 90 12 165 7.1 0 7.5 7 03/23/2006 14:00:00 3.6 0.7 5.3 1.9 3.6 0.7 4.9 1.9 3.2 0.7 4.9 1.5 295 15 311 165 6.4 0.3 7.3 6 03/23/2006 14:10:00 4.2 0.6 5.3 3 4.2 0.6 5.7 3 3.2 0.5 4.6 1.9 299 5 298 165 6.1 0.1 6.2 5.7 03/23/2006 14:20:00 4.6 0.5 5.7 3.4 4.5 0.5 5.7 3.4 3.7 0.6 4.9 2.3 301 6 293 165 5.7 0 5.7 5.5 03/23/2006 14:30:00 3.3 0.7 4.9 1.1 3.3 0.7 4.6 1.5 2.7 0.6 4.2 1.5 297 10 301 165 6.1 0.2 6.7 5.5 03/23/2006 14:40:00 2.7 0.4 3.8 1.1 2.8 0.4 3.8 1.5 2.6 0.5 4.2 1.1 282 8 293 165 6.4 0 6.7 6.2 03/23/2006 14:50:00 1.7 0.8 3.4 0.4 1.7 0.8 3.4 0.4 1.5 0.7 3 0.4 273 53 314 165 7.2 0.5 8 6.2 03/23/2006 15:00:00 1.4 0.5 2.6 0.4 1.4 0.6 2.3 0.4 1.2 0.6 2.6 0.4 324 20 332 165 7.7 0.2 8.3 7.3 03/23/2006 15:10:00 0.8 0.6 2.3 0.4 0.8 0.6 2.3 0.4 0.8 0.6 2.3 0.4 328 5 333 165 8.7 0.8 10.3 7.5 03/23/2006 15:20:00 0.9 0.5 2.3 0.4 0.9 0.5 2.3 0.4 0.9 0.6 2.3 0.4 130 69 108 165 8.6 1.2 10.6 7 03/23/2006 15:30:00 0.8 0.4 1.5 0.4 0.8 0.4 1.5 0.4 0.9 0.5 2.3 0.4 117 17 142 165 6.7 0.3 7.5 6.2 03/23/2006 15:40:00 1.1 0.4 2.3 0.4 1.1 0.4 2.3 0.4 1 0.4 2.3 0.4 93 15 87 165 6.9 0 7.3 6.7 03/23/2006 15:50:00 0.9 0.5 1.9 0.4 0.8 0.4 1.9 0.4 0.7 0.4 1.9 0.4 90 19 63 165 6.4 0.4 7.3 5.7 03/23/2006 16:00:00 1.3 0.5 2.3 0.4 1.3 0.5 2.3 0.4 1.2 0.5 2.3 0.4 108 12 120 165 5.6 0 6 5.5 03/23/2006 16:10:00 1.9 0.6 3.4 0.4 1.8 0.7 3.4 0.4 1.9 0.6 3.4 0.4 114 17 88 165 5.3 0 5.7 5 03/23/2006 16:20:00 2.1 0.6 3 0.4 2.1 0.6 3 0.4 2 0.6 3.4 0.4 113 13 102 165 5.1 0 5.2 5 03/23/2006 16:30:00 1.4 0.6 3 0.4 1.3 0.7 2.6 0.4 1.2 0.6 2.3 0.4 102 22 72 165 5.1 0 5.5 4.8 03/23/2006 16:40:00 1.4 0.5 2.3 0.4 1.4 0.4 2.3 0.4 1.3 0.5 2.6 0.4 62 19 32 165 5.1 0 5.5 5 03/23/2006 16:50:00 1.2 0.5 2.3 0.4 1.2 0.5 2.3 0.4 1.2 0.5 1.9 0.4 107 24 124 165 4.9 0 5.2 4.8 03/23/2006 17:00:00 1.1 0.6 2.3 0.4 1.1 0.5 2.3 0.4 1.1 0.5 2.3 0.4 60 33 34 165 5.4 0.2 6.2 5 03/23/2006 17:10:00 1.1 0.5 2.3 0.4 1.1 0.4 2.3 0.4 1 0.4 1.9 0.4 55 17 39 165 5.9 0.4 7 5.5 03/23/2006 17:20:00 0.9 0.4 1.9 0.4 0.8 0.4 1.9 0.4 1 0.3 1.5 0.4 43 14 51 165 6.4 0.3 7.3 5.5 03/23/2006 17:30:00 1.3 0.5 2.3 0.4 0.9 0.4 1.9 0.4 1.3 0.5 2.3 0.4 12 15 354 165 5.4 0 6 5.2 03/23/2006 17:40:00 1.9 0.4 2.6 1.1 1.3 0.5 2.6 0.4 1.8 0.4 3 1.1 4 10 12 165 4.9 0.3 5.5 4.5 03/23/2006 17:50:00 1.5 0.4 2.3 0.4 1 0.4 2.3 0.4 1.6 0.5 2.3 0.4 3 13 10 165 4.7 0 4.8 4.5 03/23/2006 18:00:00 1.2 0.5 2.3 0.4 0.9 0.4 1.9 0.4 1 0.5 2.3 0.4 355 7 359 165 4.5 0 4.8 4.3 03/23/2006 18:10:00 0.9 0.3 1.5 0.4 1 0.3 1.9 0.4 0.9 0.3 1.5 0.4 305 23 310 165 4 0.2 4.5 3.5 03/23/2006 18:20:00 1.2 0.3 1.9 0.4 0.9 0.3 1.9 0.4 1.2 0.3 1.9 0.4 351 22 342 165 3.6 0 3.8 3.5 03/23/2006 18:30:00 0.8 0.4 1.5 0.4 0.7 0.4 1.5 0.4 1 0.4 1.9 0.4 350 22 10 165 3.6 0.1 3.8 3.3 03/23/2006 18:40:00 2.1 0.2 2.6 1.1 2.1 0.2 2.6 1.5 2.1 0.2 2.6 1.5 322 8 320 165 3.1 0 3.5 2.8 03/23/2006 18:50:00 2.5 0.3 3 1.9 2.6 0.2 3 1.9 2.5 0.3 3 1.9 334 9 340 165 2.7 0.2 3 2.3 03/23/2006 19:00:00 2.7 0.3 3.4 1.9 2.7 0.3 3.4 2.3 2.5 0.3 3 1.9 310 5 310 165 2.6 0 2.8 2.3 03/23/2006 19:10:00 2.9 0.2 3.8 2.3 3 0.2 3.8 2.3 2.4 0.3 3.4 1.5 302 5 295 165 2.5 0 2.8 2.3 03/23/2006 19:20:00 2.9 0.3 3.8 2.3 2.9 0.3 3.8 2.3 2.7 0.3 3.8 1.9 308 5 304 165 2.4 0 3 2.3 03/23/2006 19:30:00 3.4 0.5 4.6 1.9 3.4 0.5 4.6 2.3 3 0.5 4.6 1.9 307 4 307 165 2.2 0 2.3 1.8 03/23/2006 19:40:00 4.1 0.6 5.3 2.6 4.2 0.6 5.3 2.6 3.4 0.6 4.9 1.9 300 5 294 165 1.9 0.1 2.3 1.8 03/23/2006 19:50:00 4.8 0.4 5.7 3.4 4.9 0.4 5.7 3.4 4.2 0.6 5.7 2.6 292 5 294 165 1.7 0 1.8 1.6 03/23/2006 20:00:00 5.1 0.6 6.5 3.4 5.1 0.6 6.5 3 4.5 0.8 6.1 2.3 290 6 288 165 1.7 0 1.8 1.4 03/23/2006 20:10:00 5.6 0.4 6.5 4.2 5.7 0.4 6.5 4.6 4.9 0.7 6.5 3.4 292 4 289 165 1.4 0 1.6 1.4 03/23/2006 20:20:00 5.1 0.4 6.5 3.8 5.1 0.4 6.5 4.2 4.4 0.7 6.1 2.6 293 4 290 165 1.4 0 1.8 1.4 03/23/2006 20:30:00 4 0.6 4.9 2.6 4.1 0.6 5.3 2.6 3.3 0.5 4.6 2.3 301 6 298 165 1.7 0 1.8 1.4 03/23/2006 20:40:00 3.6 0.5 4.6 2.6 3.8 0.5 4.9 2.6 3 0.4 3.8 2.3 302 7 300 165 1.8 0 2.1 1.6 03/23/2006 20:50:00 3.2 0.5 4.6 2.3 3.4 0.5 4.6 2.3 2.8 0.4 4.2 1.9 300 7 302 165 1.7 0 1.8 1.4 03/23/2006 21:00:00 2.7 0.5 3.8 1.9 2.9 0.4 4.2 1.9 2.6 0.4 3.4 1.9 295 5 298 165 1.7 0 1.8 1.4 03/23/2006 21:10:00 4 0.4 5.7 2.6 4.1 0.4 5.7 3 3.4 0.4 4.6 2.6 303 6 294 165 1.5 0.1 1.8 1.4 03/23/2006 21:20:00 4 0.4 5.3 3 4.1 0.4 5.7 3.4 3.4 0.4 5.3 2.3 303 5 302 165 1.3 0 1.6 0.9 03/23/2006 21:30:00 4.3 0.5 5.7 3 4.4 0.5 5.7 2.6 3.6 0.5 4.9 2.6 303 5 304 165 0.9 0.1 1.4 0.7 03/23/2006 21:40:00 5.2 0.6 6.8 3.4 5.3 0.7 6.8 3.8 4.3 0.7 6.5 2.6 296 7 295 165 0.8 0 0.9 0.7 03/23/2006 21:50:00 5.6 0.5 7.2 4.6 5.7 0.5 7.2 4.6 4.7 0.6 6.5 3 294 5 293 165 1 0 1.4 0.9 03/23/2006 22:00:00 4.7 0.7 6.8 3.4 4.9 0.7 6.8 3.4 4 0.8 7.2 2.6 299 6 295 165 1.1 0 1.4 0.9 03/23/2006 22:10:00 3.9 0.6 5.7 2.6 4.1 0.6 5.7 3 3.5 0.6 5.3 1.9 297 7 291 165 1.2 0 1.4 0.9 03/23/2006 22:20:00 4.3 0.7 6.1 2.6 4.4 0.6 6.1 3 3.7 0.6 5.7 2.6 296 5 295 165 1.1 0 1.6 0.9 03/23/2006 22:30:00 4.6 0.6 5.7 3.4 4.7 0.6 6.1 3.4 4 0.6 5.7 2.6 292 6 291 165 1.1 0 1.4 0.9 03/23/2006 22:40:00 4.7 0.6 7.2 3.4 4.8 0.6 6.8 3.4 4.1 0.7 6.8 3 298 7 298 165 0.9 0 1.1 0.7 03/23/2006 22:50:00 6 0.8 7.6 4.2 6 0.7 7.6 4.6 4.7 0.7 6.5 3 299 5 299 165 0.7 0 0.9 0.4 03/23/2006 23:00:00 5.9 0.7 7.2 3.8 6 0.7 7.2 3.8 5.1 0.9 7.2 3 291 5 285 165 0.4 0.1 0.7 0.2 03/23/2006 23:10:00 5.8 0.4 6.8 4.6 5.9 0.4 6.8 4.6 4.9 0.7 6.8 3 295 5 302 165 0.2 0 0.4 0.2 03/23/2006 23:20:00 5.7 0.6 7.2 4.2 5.8 0.6 7.2 4.6 4.5 0.6 6.5 3 300 5 301 165 0.3 0 0.7 0.2 03/23/2006 23:30:00 4.8 0.6 6.1 3.4 4.9 0.5 6.1 3.4 4 0.6 5.7 3 301 5 300 165 0.5 0 0.9 0.2 03/23/2006 23:40:00 5.1 0.6 6.5 3.4 5.2 0.6 6.8 3.8 4 0.6 5.3 2.6 297 5 293 165 0.5 0 0.7 0.2 03/23/2006 23:50:00 4.3 0.7 5.7 2.6 4.4 0.7 6.1 2.6 3.6 0.7 5.3 2.3 306 7 299 165 0.4 0.1 0.7 0.2 03/24/2006 00:00:00 5.4 1.1 8 2.6 5.5 1.1 8 3 4.5 0.9 7.6 2.6 302 8 300 165 0.3 0 0.7 0.2 03/24/2006 00:10:00 7.4 0.5 8.4 5.7 7.4 0.6 8.8 5.7 5.7 0.7 7.6 4.2 297 4 298 165 0.1 0 0.7 -0.1 03/24/2006 00:20:00 6.7 0.7 8.8 4.9 6.7 0.7 8.8 4.6 5.3 0.6 6.8 3.8 302 5 305 165 -0.1 0 0.2 -0.3 03/24/2006 00:30:00 6.9 0.6 8.4 4.9 6.9 0.6 8.4 5.3 5.3 0.6 7.2 3.8 298 4 302 165 -0.1 0 0.2 -0.3 03/24/2006 00:40:00 6.6 0.7 8 4.2 6.6 0.7 8 4.2 5.1 0.7 7.2 3 301 6 306 165 -0.1 0 0.2 -0.3 03/24/2006 00:50:00 5.6 0.7 7.2 3.4 5.7 0.6 6.8 3.8 4.5 0.6 5.7 3 302 5 298 165 -0.1 0 0.2 -0.3 03/24/2006 01:00:00 4.2 0.6 5.7 2.6 4.3 0.6 6.1 3 3.7 0.8 6.1 2.3 300 7 303 165 -0.1 0 0.2 -0.3 03/24/2006 01:10:00 6.1 1 8.4 4.2 6.2 1 8.4 4.2 5 0.9 7.6 3 295 5 290 165 -0.3 0.1 0.2 -1 03/24/2006 01:20:00 7.2 0.5 8.4 6.1 7.3 0.5 8.8 6.1 6.2 0.8 8.4 4.2 293 4 284 165 -0.6 0 -0.5 -1.2 03/24/2006 01:30:00 6.2 0.8 8 3.8 6.2 0.8 8 3.8 5.1 1 8 3 295 6 290 165 -0.6 0 -0.5 -0.8 03/24/2006 01:40:00 5 1.2 7.2 2.3 5 1.1 7.2 2.3 4.2 1.1 6.5 1.9 301 10 307 165 -0.5 0.1 -0.3 -0.8 03/24/2006 01:50:00 5.8 0.7 7.6 3.8 5.8 0.7 7.6 4.2 4.8 0.8 7.2 2.6 291 7 294 165 -0.4 0 -0.1 -0.8 03/24/2006 02:00:00 5.6 0.7 7.2 3.8 5.7 0.7 7.2 3.8 4.7 0.9 6.8 3 291 5 292 165 -0.5 0 -0.3 -1 03/24/2006 02:10:00 6 0.4 6.8 4.9 6.1 0.4 7.2 4.9 5 0.7 6.8 3 293 5 286 165 -0.5 0 -0.3 -0.8 03/24/2006 02:20:00 5.5 0.5 6.8 4.2 5.6 0.5 6.8 4.2 4.6 0.6 6.5 3.4 294 5 294 165 -0.3 0.1 -0.1 -0.5 03/24/2006 02:30:00 5.3 0.4 6.5 4.2 5.4 0.5 6.5 4.2 5.1 0.8 6.8 3.4 286 5 283 165 0 0 0.2 -0.3 03/24/2006 02:40:00 5.1 0.5 6.1 3.8 5.2 0.5 6.5 4.2 5.3 0.5 6.8 3.8 283 4 286 165 -0.2 0.1 0.7 -0.5 03/24/2006 02:50:00 4.6 0.4 5.3 3.4 4.8 0.4 5.7 3.8 5 0.4 6.1 3.8 282 5 288 165 -0.2 0 -0.1 -0.8 03/24/2006 03:00:00 4.6 0.4 5.7 3.8 4.7 0.4 5.7 3.8 4.7 0.5 6.1 2.6 283 4 288 165 0.1 0.2 0.4 -0.3 03/24/2006 03:10:00 3.7 0.5 5.3 2.6 3.8 0.5 5.3 2.6 3.4 0.6 4.6 2.3 292 5 293 165 0 0 0.2 -0.5 03/24/2006 03:20:00 3.2 0.4 4.2 1.5 3.4 0.4 4.6 1.9 2.7 0.4 3.8 1.9 294 5 279 165 0 0 0.2 -0.3 03/24/2006 03:30:00 3.4 0.4 4.2 2.6 3.6 0.4 4.6 2.6 3.1 0.4 4.6 2.3 290 4 295 165 -0.2 0.1 0.7 -0.8 03/24/2006 03:40:00 3.3 0.5 4.2 1.1 3.5 0.4 4.2 2.3 3.3 0.4 4.2 2.3 279 4 285 165 -0.2 0.1 -0.1 -0.5 03/24/2006 03:50:00 4.4 0.4 5.3 3.4 4.5 0.4 5.3 3.4 3.7 0.5 4.9 2.3 294 8 302 165 -0.5 0.1 -0.3 -0.8 03/24/2006 04:00:00 5.3 0.4 6.1 4.6 5.3 0.4 6.1 4.2 3.9 0.5 5.3 2.3 303 3 303 165 -0.3 0.2 -0.1 -0.8 03/24/2006 04:10:00 5.1 0.6 6.5 3.4 5.1 0.6 6.5 3.4 3.9 0.5 5.3 2.6 303 5 303 165 -0.2 0 -0.1 -0.3 03/24/2006 04:20:00 5.5 0.4 6.5 4.6 5.6 0.4 6.5 4.9 4.3 0.6 6.1 3 299 4 286 165 -0.2 0.1 -0.1 -0.5 03/24/2006 04:30:00 5.3 0.8 6.8 2.6 5.3 0.8 6.8 2.6 4.7 1 6.8 1.9 292 9 284 165 -0.4 0 -0.1 -0.8 03/24/2006 04:40:00 5.8 1 7.2 2.3 5.7 1 7.6 2.6 4.9 0.9 8 3 305 11 306 165 -0.6 0.1 -0.3 -0.8 03/24/2006 04:50:00 6.5 0.9 8.8 3.4 6.4 0.9 8.8 3.8 5.1 0.7 7.6 3.4 303 6 294 165 -0.8 0.2 -0.5 -1.2 03/24/2006 05:00:00 4.8 1.7 8.8 1.9 4.8 1.7 8.8 1.5 4.3 1.2 6.8 1.5 314 15 309 165 -1.6 0.3 -1 -2.6 03/24/2006 05:10:00 5.5 1.3 8.4 1.9 5.4 1.3 8 1.9 4.4 1 8 1.9 303 9 304 165 -2 0.1 -1.4 -2.6 03/24/2006 05:20:00 7.5 0.7 9.1 5.3 7.4 0.7 9.1 4.9 6 0.9 8 3.8 304 6 297 165 -1.7 0 -1.4 -2.6 03/24/2006 05:30:00 5.8 0.9 8 3.8 5.9 0.8 8 3.8 4.8 0.9 8 2.6 299 8 295 165 -1.6 0 -1.4 -1.9 03/24/2006 05:40:00 5 0.8 7.6 3.4 5.1 0.8 7.6 3.4 4.5 1 7.2 2.6 294 9 282 165 -1.3 0 -0.8 -1.7 03/24/2006 05:50:00 5.3 1.1 8.4 2.6 5.4 1.1 8.8 2.6 4.4 0.9 6.8 2.3 298 7 297 165 -1.3 0.1 -0.8 -1.9 03/24/2006 06:00:00 7.7 0.8 9.9 4.9 7.7 0.8 9.9 4.9 6.3 1 9.1 3.8 295 5 290 165 -1.6 0 -1.4 -2.1 03/24/2006 06:10:00 7.6 1 9.5 4.2 7.6 1 9.1 4.2 6 1 8.4 3.4 298 7 292 165 -1.6 0 -1.4 -2.1 03/24/2006 06:20:00 5.4 1 8.4 3 5.4 1 8 3 4.7 0.7 6.5 2.6 314 13 297 165 -1.8 0.2 -1.4 -2.1 03/24/2006 06:30:00 4.3 0.7 6.5 2.6 4.3 0.8 6.5 1.5 4.1 0.7 6.1 1.9 325 14 325 165 -2 0 -1.7 -2.1 03/24/2006 06:40:00 3.8 1 6.1 0.4 3.9 1 5.7 0.7 3.5 0.6 4.9 1.5 311 17 298 165 -1.8 0 -1.4 -2.1 03/24/2006 06:50:00 2.8 0.8 4.9 0.7 3.1 0.7 5.3 1.5 2.6 0.6 4.6 1.5 300 13 290 165 -1.8 0.1 -1.4 -2.1 03/24/2006 07:00:00 2.5 0.9 4.9 0.4 2.8 0.8 4.9 1.1 2.3 0.8 4.6 0.4 296 13 290 165 -1.4 0.1 -1.2 -1.9 03/24/2006 07:10:00 3.3 0.8 5.3 1.1 3.6 0.8 5.7 1.5 3 0.7 4.9 1.9 303 10 291 165 -1.4 0.2 -1 -2.1 03/24/2006 07:20:00 4.1 0.7 6.1 2.6 4.2 0.7 6.1 2.3 3.7 0.6 6.1 2.3 311 15 302 165 -0.9 0.1 -0.8 -1.4 03/24/2006 07:30:00 4.5 1 6.8 1.5 4.6 1 6.5 1.5 3.7 0.8 6.5 1.5 295 8 274 165 -0.9 0.1 -0.8 -1.4 03/24/2006 07:40:00 2 1.1 4.2 0.4 2.2 1.1 4.2 0.4 2.1 0.7 4.2 0.7 298 14 301 165 -0.4 0.2 0.2 -0.8 03/24/2006 07:50:00 1.1 1 4.2 0.4 1.1 1 4.2 0.4 1.2 0.9 3 0.4 3 47 278 165 0.2 0.1 0.7 -0.1 03/24/2006 08:00:00 0.8 0.8 3 0.4 0.9 0.8 3 0.4 1.4 1 3.8 0.4 276 39 295 165 0.2 0.3 1.1 -0.3 03/24/2006 08:10:00 2 0.6 3 0.4 2.1 0.7 3.4 0.4 2.5 0.6 3.8 1.1 269 17 278 165 -0.3 0 -0.1 -0.5 03/24/2006 08:20:00 1.9 0.7 3 0.4 1.7 0.9 3 0.4 2 0.7 3.4 0.4 254 27 241 165 0.1 0.1 0.4 -0.3 03/24/2006 08:30:00 3.6 1 6.1 1.9 3.4 1.1 5.7 1.5 3.1 1.1 5.7 1.1 307 8 309 165 0.5 0.1 0.9 0.2 03/24/2006 08:40:00 3.4 0.9 5.7 1.1 3.4 1 5.7 0.7 2.7 1 4.9 0.4 304 17 307 165 0.6 0.2 1.1 0.2 03/24/2006 08:50:00 5.4 1.4 8 1.9 5.4 1.4 8 1.9 4.1 1.5 6.8 0.4 304 12 301 165 1.1 0.1 1.6 0.7 03/24/2006 09:00:00 5.7 1.1 8 3.4 5.6 1.1 8 3.4 4.5 1.1 6.8 2.3 306 9 312 165 0.9 0.1 1.4 0.7 03/24/2006 09:10:00 3.9 1.1 7.2 1.5 3.9 1.1 6.8 1.9 3 1 5.7 0.4 298 18 300 165 1.7 0.3 2.3 1.1 03/24/2006 09:20:00 3.7 1 6.5 1.1 3.7 1 6.1 1.5 3 1 5.7 0.4 296 13 277 165 1.8 0.2 2.3 1.4 03/24/2006 09:30:00 4.4 1.1 6.8 1.9 4.4 1.1 6.8 1.5 3.7 1.1 6.1 1.1 298 13 286 165 1.8 0.2 2.3 1.4 03/24/2006 09:40:00 4.9 1.1 8 1.5 4.9 1.1 8 1.5 4.2 1 6.5 1.9 295 13 297 165 1.7 0.1 2.1 1.4 03/24/2006 09:50:00 6 1 9.1 3.4 6 1 8.8 3.8 5.1 0.9 8.4 2.3 301 12 286 165 1.4 0.2 1.8 1.1 03/24/2006 10:00:00 6.7 1.4 9.9 3.4 6.7 1.3 9.9 3.4 5.6 1.3 9.1 3 298 10 297 165 1.4 0.3 2.1 0.9 03/24/2006 10:10:00 7.7 1 10.3 4.9 7.6 1 10.3 4.9 6.8 1.2 9.9 4.2 296 12 301 165 1 0.1 1.4 0.7 03/24/2006 10:20:00 7.2 0.9 11.1 4.9 7.2 0.9 10.7 4.9 5.8 1 8.4 3 294 8 289 165 0.8 0.1 1.1 0.7 03/24/2006 10:30:00 4.7 1.8 9.1 1.9 4.9 2 9.5 1.9 4.6 1.8 9.9 1.1 287 18 297 165 1.2 0.4 2.1 0.7 03/24/2006 10:40:00 4.4 1.4 7.2 0.7 4.6 1.5 7.2 0.4 4.5 1.5 7.2 0.7 285 27 274 165 1.7 0.2 2.3 1.4 03/24/2006 10:50:00 3.9 1.2 6.8 0.4 4.1 1.3 7.2 0.4 3.8 1.5 6.8 0.4 285 23 266 165 2.3 0.4 3 1.4 03/24/2006 11:00:00 4.8 1.1 8.8 2.3 4.8 1.1 8.4 2.3 4.4 1.1 8 2.3 291 12 289 165 1.6 0.2 2.6 1.4 03/24/2006 11:10:00 4.8 1.1 7.6 2.3 4.8 1 7.6 2.3 4.1 1 6.5 1.5 298 12 298 165 2 0.4 3.3 1.4 03/24/2006 11:20:00 5.7 1 8 2.6 5.7 1 7.6 2.6 4.6 0.9 7.2 2.3 297 9 293 165 1.8 0.1 2.6 1.6 03/24/2006 11:30:00 7.4 1 11.5 4.9 7.4 1 11.1 4.6 6.3 1.3 9.5 3.8 298 10 291 165 1.4 0.2 1.8 0.9 03/24/2006 11:40:00 8 1.1 11.1 5.7 7.9 1.1 10.7 5.7 7 1 10.7 4.6 305 11 287 165 1.2 0 1.4 1.1 03/24/2006 11:50:00 8.4 0.6 10.3 6.8 8.3 0.7 9.9 6.5 7.3 0.9 9.1 4.9 307 7 302 165 1.5 0.1 2.1 1.4 03/24/2006 12:00:00 6.9 1 9.5 4.6 6.9 1 9.5 4.6 5.8 1 8.8 3.4 304 8 310 165 1.8 0 2.3 1.6 03/24/2006 12:10:00 7.4 0.7 9.1 4.9 7.4 0.7 9.1 4.9 6 1 8.8 3.8 297 6 297 165 1.5 0 1.6 1.4 03/24/2006 12:20:00 7.7 1.2 11.1 4.6 7.7 1.2 11.1 4.6 6 1.1 8.8 2.6 302 6 297 165 1.7 0 1.8 1.6 03/24/2006 12:30:00 7.8 1.3 10.7 4.2 7.8 1.3 11.1 4.2 6.6 1 8.8 3.8 303 9 294 165 1.8 0.1 2.3 1.6 03/24/2006 12:40:00 6.6 1.2 9.5 4.2 6.6 1.2 9.1 4.2 5.7 1.2 9.1 2.6 299 11 291 165 2.4 0.2 2.8 1.8 03/24/2006 12:50:00 6.8 0.7 8.8 4.9 6.8 0.7 8.8 4.9 6.1 1 8.8 3.8 288 9 281 165 1.8 0.1 2.1 1.6 03/24/2006 13:00:00 8.4 0.8 10.3 6.5 8.4 0.9 10.3 6.1 6.9 0.9 9.9 4.9 305 5 305 165 1.8 0 2.1 1.6 03/24/2006 13:10:00 7.9 0.9 9.9 5.3 7.9 0.9 9.9 5.3 7 1.2 9.9 3.8 293 9 284 165 2 0.1 2.3 1.6 03/24/2006 13:20:00 9.4 0.7 11.5 7.2 9.4 0.7 11.5 7.6 8.5 1.1 10.7 5.3 289 6 282 165 1.7 0 2.1 1.4 03/24/2006 13:30:00 8.1 1.1 11.1 4.9 8 1.1 11.1 4.9 6.8 1.1 10.3 3.8 302 8 302 165 2 0 2.3 1.6 03/24/2006 13:40:00 8.3 1 11.5 6.5 8.3 0.9 11.1 6.1 6.6 1 9.5 4.2 298 7 309 165 2 0 2.3 1.8 03/24/2006 13:50:00 7.8 0.9 9.9 5.3 7.8 0.9 9.9 5.3 5.9 0.8 8.4 4.2 299 5 298 165 2.2 0 2.6 1.8 03/24/2006 14:00:00 6.5 1.2 8.8 2.6 6.6 1.1 8.8 3.8 5.7 1 8 2.3 289 11 300 165 2.3 0.1 3.3 1.8 03/24/2006 14:10:00 5.6 0.9 7.6 3.4 5.6 0.9 7.6 3.4 5 0.8 6.8 2.6 289 11 297 165 2.7 0.1 3.3 2.3 03/24/2006 14:20:00 6.2 0.8 8 3.4 6.3 0.7 8 4.6 6 1 8.8 3 283 8 278 165 2.4 0 2.8 2.1 03/24/2006 14:30:00 6 0.8 8 3.8 6 0.8 7.6 3.8 5.4 0.8 7.6 3 291 9 295 165 2.5 0.1 3.3 2.3 03/24/2006 14:40:00 5 0.7 6.5 3 5 0.8 6.5 2.6 4.5 0.8 6.5 2.6 302 11 303 165 2.9 0.1 3.3 2.6 03/24/2006 14:50:00 6.1 0.9 8.4 3.8 6.1 1 8.4 3.8 5.2 1.1 8 3 294 8 289 165 2.9 0.1 3.5 2.3 03/24/2006 15:00:00 5.9 0.8 7.6 3.4 5.8 0.8 7.6 3.4 4.8 0.9 7.2 1.9 299 7 297 165 2.9 0.1 3 2.3 03/24/2006 15:10:00 5.7 1.1 8 3.4 5.7 1.1 8 3.4 5 1 7.6 2.3 303 9 302 165 3.1 0.1 3.5 2.8 03/24/2006 15:20:00 7.7 0.8 9.9 5.3 7.7 0.8 9.9 5.3 6.1 0.9 9.9 4.2 303 6 309 165 2.7 0.1 3.3 2.3 03/24/2006 15:30:00 6.5 1 8.4 4.2 6.4 1 8.4 4.2 5.5 0.9 7.6 3.4 303 9 295 165 2.9 0.1 3.5 2.6 03/24/2006 15:40:00 6.6 0.6 8.4 4.9 6.6 0.6 8.4 4.9 5.3 0.6 7.6 3.8 297 6 293 165 2.8 0 3.3 2.6 03/24/2006 15:50:00 6.4 0.6 8.4 4.6 6.6 0.6 8.4 4.9 6.1 1 8 3.8 281 9 276 165 2.6 0.1 2.8 2.3 03/24/2006 16:00:00 5.2 1 8 3 5.3 1 8 3 5.2 1 8.4 3 284 7 283 165 2.6 0 2.8 2.3 03/24/2006 16:10:00 5.4 0.7 7.6 3.4 5.4 0.7 7.2 3.4 4.6 0.8 7.2 2.6 295 9 285 165 2.8 0 3 2.6 03/24/2006 16:20:00 4.9 1.1 7.2 2.6 4.9 1.1 7.2 2.6 4.4 1 6.8 1.9 293 14 289 165 2.8 0.1 3.3 2.6 03/24/2006 16:30:00 3.7 0.5 4.9 2.3 3.7 0.5 4.9 1.9 3.2 0.6 5.3 1.9 309 17 310 165 3.7 0.3 4.3 3.3 03/24/2006 16:40:00 5.3 1 7.6 2.6 4.8 1.3 7.6 2.3 5.2 1 7.2 2.3 342 13 338 165 4 0.1 4.5 3.5 03/24/2006 16:50:00 5.3 0.8 7.2 3 5.2 0.8 6.8 3 4.6 0.6 6.8 3 314 17 291 165 3.6 0.2 4 3.3 03/24/2006 17:00:00 6.2 0.9 9.1 3.8 6.1 0.9 9.1 3.8 5.3 1 8.8 3.4 302 13 319 165 2.7 0.2 3.3 2.3 03/24/2006 17:10:00 6 0.7 7.6 4.2 6 0.7 7.6 4.2 5 0.8 7.2 3 306 10 300 165 2.5 0.2 3.3 2.1 03/24/2006 17:20:00 6.8 0.6 8 4.6 6.8 0.6 8 4.9 5.7 0.8 8 3.8 304 6 305 165 2.2 0.2 2.6 1.8 03/24/2006 17:30:00 6.8 1 8.4 4.2 6.8 1 8.4 4.2 6.3 1.1 8.8 3.4 311 7 309 165 2.1 0 2.6 1.8 03/24/2006 17:40:00 7.4 0.8 8.8 4.9 7.4 0.8 8.8 4.6 5.7 0.7 8 3.8 301 6 301 165 2.1 0.1 2.8 1.8 03/24/2006 17:50:00 7.4 0.7 9.1 5.3 7.3 0.7 8.8 5.7 5.8 0.8 8.4 4.2 301 7 298 165 2 0.1 2.3 1.8 03/24/2006 18:00:00 7.5 1 9.5 4.9 7.5 1 9.9 5.3 6.2 1.1 8.8 3.4 304 7 297 165 1.8 0 2.3 1.6 03/24/2006 18:10:00 6.9 0.7 9.5 4.6 6.9 0.7 9.1 4.6 5.8 1 9.1 3.4 300 10 284 165 1.7 0 2.3 1.4 03/24/2006 18:20:00 7 0.6 8.4 4.9 7 0.6 8.4 4.9 5.9 0.8 8 4.2 305 7 295 165 1.6 0 1.8 1.4 03/24/2006 18:30:00 6.8 0.8 9.1 4.6 6.8 0.8 8.8 4.6 5.2 0.8 6.8 3 301 5 301 165 1.5 0.1 1.8 1.4 03/24/2006 18:40:00 6.9 0.8 8.8 4.6 6.9 0.8 8.8 4.6 5.2 0.8 8 3.4 301 5 296 165 1.3 0.1 1.8 1.1 03/24/2006 18:50:00 7.5 0.8 9.5 5.7 7.5 0.8 9.1 4.9 5.7 0.7 8 4.2 302 6 292 165 1.1 0 1.6 0.9 03/24/2006 19:00:00 7.9 0.7 9.9 6.1 7.8 0.7 9.9 5.7 6.2 0.9 8.4 4.6 303 6 297 165 0.9 0.1 1.4 0.7 03/24/2006 19:10:00 8 0.8 9.5 5.7 7.9 0.9 9.9 5.3 6.7 0.8 8.4 4.9 308 6 305 165 0.6 0 0.9 0.2 03/24/2006 19:20:00 7.3 0.7 8.8 5.3 7.2 0.7 9.1 5.3 6.2 0.8 8 4.2 306 6 304 165 0.3 0 0.7 0.2 03/24/2006 19:30:00 6.6 0.5 8.4 5.3 6.5 0.6 8.8 4.9 4.9 0.6 6.8 3.4 301 6 290 165 0.2 0 0.4 0.2 03/24/2006 19:40:00 7.2 0.6 8.4 5.7 7.1 0.6 8.8 5.7 5.6 0.7 7.6 3.8 305 5 297 165 0.2 0 0.4 0.2 03/24/2006 19:50:00 7.2 0.7 8.8 5.3 7.1 0.6 8.8 5.7 6.2 1 9.1 4.2 310 8 314 165 0.1 0 0.2 -0.1 03/24/2006 20:00:00 7.4 0.9 9.5 4.9 7.3 0.8 9.5 4.9 6.2 0.8 8.4 4.2 306 8 313 165 0.2 0 0.4 -0.1 03/24/2006 20:10:00 7.7 0.8 9.5 5.3 7.6 0.8 9.5 5.3 6.4 0.9 9.1 4.2 307 7 296 165 0.1 0 0.2 -0.1 03/24/2006 20:20:00 6.9 0.9 8.8 4.2 6.8 0.9 8.8 4.2 6 1 8.4 3.8 308 7 315 165 0.1 0 0.2 -0.1 03/24/2006 20:30:00 5.3 1.1 8 3.4 5.2 1.1 8.8 3.4 4.9 1 7.6 3 316 10 314 165 0.1 0 0.2 -0.1 03/24/2006 20:40:00 4.9 0.7 6.5 3.4 4.8 0.7 6.1 3 4.7 0.8 6.5 2.6 316 8 313 165 0.1 0 0.2 -0.1 03/24/2006 20:50:00 4.8 0.7 6.8 3.4 4.7 0.6 6.5 3.4 4.8 0.6 6.1 3.4 317 8 313 165 0.1 0 0.2 -0.1 03/24/2006 21:00:00 4.5 0.7 6.5 3 4.5 0.7 6.5 3 4.4 0.8 6.1 2.3 316 8 313 165 0.1 0 0.2 -0.1 03/24/2006 21:10:00 4.8 0.6 6.8 3 4.8 0.6 6.5 3 4.5 0.6 6.1 3 317 12 313 165 0.1 0 0.2 -0.1 03/24/2006 21:20:00 5.9 0.9 8.4 3.8 5.8 0.9 8.4 4.2 5.2 0.7 6.8 3.4 312 10 305 165 0.1 0 0.2 -0.1 03/24/2006 21:30:00 5.9 0.8 8 4.2 5.8 0.7 8 4.2 5.6 0.7 8 3.8 318 8 310 165 0.1 0 0.2 -0.1 03/24/2006 21:40:00 6.4 0.6 7.6 4.9 6.4 0.6 7.6 4.6 6 0.8 7.6 3.8 312 10 311 165 0 0 0.2 -0.1 03/24/2006 21:50:00 6.3 0.6 8 4.9 6.2 0.6 8 4.6 6 0.7 7.6 3.8 316 9 325 165 -0.1 0 0.2 -0.1 03/24/2006 22:00:00 5.8 0.8 8.4 4.6 5.8 0.8 8.4 4.6 5.9 0.8 8.4 4.6 320 8 326 165 0.1 0.1 0.2 -0.1 03/24/2006 22:10:00 6.1 0.7 8 4.6 6.1 0.7 7.6 4.9 6.2 0.7 8.4 4.6 335 8 345 165 0.1 0 0.2 -0.1 03/24/2006 22:20:00 5.9 1 8.8 3.8 5.8 1 9.5 3.8 5.9 0.8 8 3.8 335 9 346 165 0.1 0 0.2 -0.1 03/24/2006 22:30:00 7.2 0.6 9.1 5.7 7.1 0.7 9.5 4.9 7.3 0.7 9.5 5.3 338 8 343 165 0.2 0 0.2 -0.1 03/24/2006 22:40:00 7.8 0.7 9.5 5.7 6.6 1.5 9.5 3.4 8.1 0.7 9.9 6.1 349 8 353 165 0.2 0 0.2 -0.1 03/24/2006 22:50:00 7.1 0.7 9.1 5.3 5.2 1.2 8.8 3 7.5 0.8 9.9 5.3 355 8 357 165 0.2 0 0.4 0.2 03/24/2006 23:00:00 7.2 0.7 9.1 5.7 5.2 1.1 8 2.6 7.6 0.7 9.5 5.7 355 6 353 165 0.3 0 0.7 0.2 03/24/2006 23:10:00 6.1 0.7 8 3.8 4 1 8 2.3 6.4 0.7 8 4.2 358 7 10 165 0.5 0 0.9 0.2 03/24/2006 23:20:00 5.7 0.6 8 4.2 3.9 1 6.8 2.3 5.9 0.6 7.6 3.8 357 7 356 165 0.4 0 0.7 0.2 03/24/2006 23:30:00 5.8 0.7 8 3.8 4.1 0.9 6.1 2.3 6 0.7 8 4.2 354 8 357 165 0.3 0 0.7 0.2 03/24/2006 23:40:00 5.6 0.7 8 4.2 3.8 1 7.2 1.5 5.9 0.8 9.1 4.2 356 8 336 165 0.4 0 0.7 -0.1 03/24/2006 23:50:00 5.4 0.6 7.6 3.8 4.6 1 7.6 2.3 5.5 0.7 7.2 3.4 347 9 341 165 0.2 0 0.4 -0.3 03/25/2006 00:00:00 4.3 0.7 6.5 2.6 3.5 0.9 6.1 1.1 4.3 0.9 6.5 2.3 345 17 357 165 0.2 0.1 0.7 -0.3 03/25/2006 00:10:00 3 0.9 4.9 0.4 3 0.8 4.9 0.4 2.9 0.8 4.9 1.1 297 17 322 165 0.1 0 0.2 -0.1 03/25/2006 00:20:00 4.3 0.5 6.1 3 4.2 0.6 6.1 1.9 3.9 0.6 5.7 2.3 312 13 310 165 -0.2 0 -0.1 -0.3 03/25/2006 00:30:00 4.6 0.8 7.2 3 4.3 0.8 7.2 1.9 4.6 0.7 7.2 2.6 334 13 355 165 -0.1 0 0.2 -0.5 03/25/2006 00:40:00 4.9 0.6 6.5 3.4 4.7 0.6 6.5 2.6 5 0.6 6.5 3.4 333 9 329 165 -0.2 0 0.2 -0.5 03/25/2006 00:50:00 4.4 0.6 5.7 3 4.3 0.6 5.7 3 4.5 0.5 5.7 3.4 330 8 328 165 -0.2 0 0.2 -0.5 03/25/2006 01:00:00 4.4 0.9 6.5 2.6 3.9 0.9 6.1 1.5 4.5 0.9 7.2 2.6 340 12 355 165 -0.1 0.2 0.2 -0.5 03/25/2006 01:10:00 3 0.7 4.9 1.9 2.4 0.8 4.6 0.4 3.2 0.7 5.3 1.9 344 13 344 165 0 0.2 0.2 -0.5 03/25/2006 01:20:00 2.5 0.7 4.6 0.7 2.2 0.7 4.6 0.4 2.4 0.6 4.2 1.1 318 22 321 165 -0.1 0.1 0.2 -0.8 03/25/2006 01:30:00 3.5 0.9 6.5 1.1 3.5 0.9 6.5 1.1 3.6 0.8 6.1 1.9 301 22 294 165 0 0 0.2 -0.3 03/25/2006 01:40:00 5 1 8 2.6 5 1.1 7.6 2.6 4.9 1 8 2.3 294 12 291 165 -0.1 0 0.2 -0.5 03/25/2006 01:50:00 6.2 1 8.8 2.6 6.2 1.1 9.1 2.6 5.8 1 8.8 3.8 293 10 294 165 -0.3 0.1 -0.1 -0.8 03/25/2006 02:00:00 6.2 1 8.8 3 6.2 1 8.8 3 5.5 1 8 3.4 298 11 286 165 -0.3 0.1 -0.1 -0.8 03/25/2006 02:10:00 6.2 0.8 9.1 4.2 6.1 0.8 9.1 4.2 5.2 0.9 8.8 3.4 302 11 295 165 -0.3 0.1 -0.1 -0.8 03/25/2006 02:20:00 5.7 1 8.8 3.4 5.5 1.1 8.8 2.6 5.6 0.9 8 2.6 325 22 308 165 -0.3 0.1 -0.1 -0.8 03/25/2006 02:30:00 6.4 0.6 8.4 4.9 5.3 1.1 8 2.6 6.5 0.8 8.4 3.8 344 18 309 165 -0.1 0 0.2 -0.8 03/25/2006 02:40:00 5.6 0.7 7.2 3.8 4.6 1.1 7.2 2.3 6 0.8 8.4 3.8 352 9 3 165 0.1 0 0.2 -0.5 03/25/2006 02:50:00 4.4 0.6 6.1 2.6 3.8 0.8 5.7 1.5 4.6 0.6 6.1 3.4 343 20 350 165 0 0 0.2 -0.3 03/25/2006 03:00:00 5.1 1 8 3 5.1 1 8 3 4.6 0.7 8 2.6 307 15 305 165 -0.3 0.1 -0.1 -0.5 03/25/2006 03:10:00 5.2 0.9 7.6 2.6 5.1 0.8 7.6 2.6 5.2 0.7 6.8 3.4 324 13 349 165 -0.3 0 -0.1 -0.5 03/25/2006 03:20:00 6.5 0.6 8.4 4.6 6.5 0.6 8.4 4.6 5.4 0.8 7.2 3.4 300 9 299 165 -0.4 0 -0.1 -0.8 03/25/2006 03:30:00 6.6 0.9 9.1 4.6 6.5 0.9 9.1 3.8 5.9 0.7 8.8 4.2 312 15 303 165 -0.5 0 -0.3 -0.8 03/25/2006 03:40:00 6.5 0.7 9.1 4.9 6.4 0.7 8.8 4.6 6 0.7 8.4 4.6 314 9 300 165 -0.5 0.1 -0.3 -0.8 03/25/2006 03:50:00 6.2 0.7 8 3.8 6.1 0.7 7.6 3.8 6.3 0.7 8 3.8 328 9 322 165 -0.6 0.1 -0.3 -1 03/25/2006 04:00:00 5.3 0.7 7.2 3 4.9 0.8 8 3 5.4 0.7 8 3.8 339 11 350 165 -0.5 0.2 -0.1 -1 03/25/2006 04:10:00 4.6 0.7 6.5 1.9 4.1 0.8 6.1 1.5 4.6 0.7 6.1 2.6 340 15 341 165 -0.4 0.2 -0.1 -0.8 03/25/2006 04:20:00 6.1 1 8.8 3.8 5.8 1.2 8.8 2.3 5.8 0.8 8.4 3.8 322 22 296 165 -0.5 0.2 -0.1 -1 03/25/2006 04:30:00 6.7 0.8 8.8 4.6 6.7 0.8 8.8 4.6 5.6 0.8 8 3.4 304 9 326 165 -0.6 0 -0.5 -1 03/25/2006 04:40:00 6.1 0.8 7.6 4.2 6 0.8 7.6 4.2 5.4 0.8 8.4 3 305 12 296 165 -0.6 0 -0.5 -0.8 03/25/2006 04:50:00 6.5 0.9 9.5 4.2 6.4 0.9 9.1 3.8 5.7 1 8.8 3.4 299 11 277 165 -0.5 0.1 -0.3 -0.8 03/25/2006 05:00:00 7.7 0.9 10.3 5.3 7.7 1 9.9 4.9 6.6 1 9.1 4.2 299 10 295 165 -0.6 0 -0.3 -1 03/25/2006 05:10:00 7.5 1.1 9.9 3.8 7.5 1.2 9.9 4.2 6.5 1 10.3 3.8 302 8 301 165 -0.5 0.1 -0.3 -1 03/25/2006 05:20:00 7 0.8 9.1 4.9 7 0.8 9.1 5.3 6 0.9 8.8 3.4 303 10 294 165 -0.6 0 -0.5 -1 03/25/2006 05:30:00 6.3 0.8 8.4 4.2 6.2 0.8 8 4.2 6.2 0.8 8.8 4.6 317 8 312 165 -0.7 0 -0.5 -1 03/25/2006 05:40:00 4.6 0.8 6.8 3 4.5 0.8 6.5 3 4.6 0.8 6.8 2.3 324 13 319 165 -0.6 0 -0.5 -1.2 03/25/2006 05:50:00 5 1.7 9.1 1.5 5 1.8 9.5 1.1 4.9 1.7 9.5 1.9 308 22 297 165 -0.4 0.1 -0.3 -1 03/25/2006 06:00:00 7.5 1.3 9.9 3.4 7.5 1.3 9.9 3.4 7.2 1.4 10.3 3 287 10 293 165 -0.6 0 -0.5 -1.2 03/25/2006 06:10:00 8.3 1.2 10.7 5.3 8.3 1.1 10.7 4.9 7 1.3 10.3 3.8 295 8 283 165 -0.8 0 -0.5 -1.2 03/25/2006 06:20:00 6.6 1.3 9.9 3.4 6.6 1.3 9.5 3.4 5.7 1.1 8.8 3 303 10 325 165 -0.6 0.1 -0.3 -1.2 03/25/2006 06:30:00 5.9 0.9 8.4 3.4 5.8 1 8.4 3.4 5.1 0.8 8.4 2.6 302 14 298 165 -0.6 0 -0.3 -1 03/25/2006 06:40:00 5.7 1.1 8.4 3.4 5.6 1.1 8.4 3.4 5.2 1 8 3.4 310 13 289 165 -0.8 0 -0.5 -0.8 03/25/2006 06:50:00 4.9 1.3 8 2.3 4.4 1.2 8.4 2.3 5 1.3 7.6 2.6 336 17 349 165 -0.6 0.2 -0.3 -0.8 03/25/2006 07:00:00 4.9 1.3 8 1.5 4.7 1.2 7.6 1.5 4.8 1.3 7.2 1.9 327 21 356 165 -0.2 0 0.2 -0.8 03/25/2006 07:10:00 3.8 1 6.5 1.1 4 0.9 6.1 1.5 4.1 0.8 6.1 1.5 282 22 296 165 -0.3 0 -0.1 -0.5 03/25/2006 07:20:00 4.7 1 6.8 2.3 5.1 1 7.2 2.3 5.4 1.1 7.6 2.3 274 12 278 165 -0.6 0 -0.5 -1 03/25/2006 07:30:00 4.7 1.2 7.2 1.9 5.1 1.2 7.6 1.5 5.3 1.1 8 2.6 274 11 256 165 -0.6 0.1 -0.3 -1.2 03/25/2006 07:40:00 4.5 1.5 7.6 0.7 4.7 1.6 8 0.4 4.9 1.5 8 1.5 284 18 291 165 -0.6 0 -0.3 -0.8 03/25/2006 07:50:00 4.7 1 7.2 1.9 4.7 1 6.8 1.9 4.4 1 7.2 2.3 296 16 336 165 -0.5 0 -0.5 -0.8 03/25/2006 08:00:00 5.5 1.8 9.5 1.5 5 1.5 9.5 1.1 5.3 1.7 9.9 1.9 325 22 4 165 -0.4 0 -0.3 -0.8 03/25/2006 08:10:00 5.1 1 8 2.3 5 1 7.2 2.3 4.7 1 8 2.6 316 22 353 165 -0.6 0 -0.5 -1 03/25/2006 08:20:00 5.4 1.1 8.8 2.6 5.4 1 8.8 2.6 4.9 1 8 1.9 299 18 338 165 -0.6 0 -0.5 -1.2 03/25/2006 08:30:00 5.1 1.1 8.4 2.6 4.7 0.8 7.6 2.3 5.1 1.1 8.8 3.4 325 17 354 165 -0.5 0 -0.3 -1 03/25/2006 08:40:00 5.5 1.4 9.1 2.6 5.3 1.3 8.8 1.9 5.3 1.3 8.8 2.6 326 16 329 165 -0.3 0.1 -0.1 -0.8 03/25/2006 08:50:00 5.5 1.3 9.1 1.9 5.3 1.1 8.4 2.6 5.1 1.3 9.9 3 318 26 353 165 -0.3 0.1 -0.1 -0.8 03/25/2006 09:00:00 5.6 0.9 8.8 3 5.4 1 8.8 2.6 5.1 0.9 7.6 2.3 314 18 301 165 -0.3 0.1 -0.3 -0.8 03/25/2006 09:10:00 5.8 1.2 8.8 3 5.8 1.2 8.8 2.6 5.1 1 8 3 301 12 291 165 -0.3 0 -0.1 -0.8 03/25/2006 09:20:00 5.9 0.9 8.4 3.4 5.8 0.9 8 3 5.5 0.9 7.6 3 310 9 313 165 -0.5 0 -0.3 -0.8 03/25/2006 09:30:00 5.4 0.8 7.6 3.4 5.3 0.8 7.6 3 4.9 0.7 6.8 3 307 13 310 165 -0.3 0 -0.3 -0.8 03/25/2006 09:40:00 6.2 0.7 8.4 4.2 6.1 0.6 8.4 4.6 6 0.8 8.4 3.4 312 13 320 165 -0.5 0.1 -0.1 -0.5 03/25/2006 09:50:00 6.4 1 8.8 4.2 6.2 1.1 9.1 2.6 6.4 0.8 8.4 4.6 334 12 330 165 0 0.1 0.2 -0.3 03/25/2006 10:00:00 6 1 8.8 3.8 5.7 1.1 8.8 3 5.9 1 8.8 3.8 339 11 359 165 0.3 0 0.7 0.2 03/25/2006 10:10:00 5.8 1.1 8.4 3.4 5.1 1.2 8.4 2.6 5.9 1.1 8.8 3.4 346 12 348 165 0.5 0 0.7 0.2 03/25/2006 10:20:00 6.2 1.2 9.5 3.4 5.5 1.1 9.1 3.4 6.3 1.2 10.3 3 342 12 350 165 0.4 0.1 0.7 0.2 03/25/2006 10:30:00 7.9 1.3 12.2 5.3 7.6 1.4 12.6 4.2 7.9 1.2 12.2 4.9 339 10 331 165 0.2 0 0.4 -0.1 03/25/2006 10:40:00 7.4 1.2 11.1 4.6 7.2 1.3 10.7 3.4 7.2 1.3 9.9 3.8 330 13 334 165 0.2 0 0.4 -0.1 03/25/2006 10:50:00 7.4 1.3 10.7 4.6 7.3 1.3 10.3 4.6 7.2 1.3 10.7 4.6 327 9 329 165 0.6 0.1 0.9 0.2 03/25/2006 11:00:00 6.8 1.2 9.9 3.8 6.7 1.2 9.9 2.3 6.5 1.2 9.1 3.4 323 17 327 165 0.8 0 0.9 0.2 03/25/2006 11:10:00 6 1 9.1 3 6 0.9 8.8 3 5.5 1.1 9.1 3 309 14 319 165 0.4 0.1 0.7 0.2 03/25/2006 11:20:00 7 1.1 9.9 4.2 6.9 1.2 10.3 4.2 6.5 1.4 10.3 3.4 321 17 339 165 0.3 0 0.7 0.2 03/25/2006 11:30:00 6.6 0.9 8.4 4.2 6.6 0.8 8.4 4.2 6.4 1 9.1 4.2 318 11 326 165 0.5 0 0.9 0.2 03/25/2006 11:40:00 6.3 0.8 8.4 4.2 6.2 0.8 8.4 4.2 6.3 1 8.4 4.2 321 10 329 165 0.6 0 0.9 0.4 03/25/2006 11:50:00 6.7 0.8 9.1 4.6 6.6 0.9 9.1 4.6 6.6 0.9 9.1 4.2 324 12 325 165 0.8 0 0.9 0.4 03/25/2006 12:00:00 7.1 0.7 9.9 5.3 7.1 0.7 9.5 5.3 7 0.8 9.5 4.6 325 11 340 165 0.9 0 1.4 0.4 03/25/2006 12:10:00 9.2 1.2 12.2 6.1 9.2 1.2 12.2 5.7 9.1 1.1 11.5 6.1 335 9 344 165 1.1 0 1.4 0.7 03/25/2006 12:20:00 9.1 1.2 12.2 6.5 9 1.3 12.6 5.7 8.9 1.3 12.6 5.3 337 10 343 165 1.1 0.1 1.4 0.7 03/25/2006 12:30:00 9.4 1.1 11.8 5.3 9.4 1.2 11.8 5.7 9 1.1 11.5 6.1 340 8 344 165 1.1 0 1.4 0.7 03/25/2006 12:40:00 9.1 1.5 12.6 5.7 9.1 1.5 13 5.7 8.6 1.3 13 5.7 338 9 346 165 1.4 0.2 2.1 0.9 03/25/2006 12:50:00 9.4 1 11.8 7.2 9.4 1.1 11.8 6.8 8.6 1.2 11.5 6.1 340 6 338 165 2.3 0.2 2.6 1.6 03/25/2006 13:00:00 9.8 0.9 11.8 7.2 9.8 1 12.2 6.5 9.4 1 11.5 5.7 340 6 339 165 2.7 0.4 3.5 2.1 03/25/2006 13:10:00 9.1 1 12.2 6.5 9.1 1.2 12.2 4.9 8.9 1 11.8 6.1 340 7 332 165 2.7 0.2 3.3 2.3 03/25/2006 13:20:00 9.5 0.8 12.2 7.2 9.5 1 12.2 6.5 9.3 0.9 11.5 6.8 340 6 338 165 2 0.2 2.6 1.6 03/25/2006 13:30:00 8.7 0.9 11.5 6.5 8.6 1 11.5 6.1 8.6 1 11.5 5.7 337 8 341 165 1.4 0.2 1.8 0.7 03/25/2006 13:40:00 9.3 1.1 12.6 6.1 9.3 1.2 12.2 5.3 9.1 1.1 12.2 5.3 340 6 333 165 1.1 0 1.4 0.7 03/25/2006 13:50:00 9.4 1.2 12.6 6.1 9 1.5 12.6 4.9 9.4 1.2 13 6.5 343 8 354 165 1.2 0.2 1.6 0.7 03/25/2006 14:00:00 9.9 1 13 8 9.7 1.3 14.1 4.9 9.8 1 12.6 7.6 341 7 343 165 1.4 0.1 1.6 0.9 03/25/2006 14:10:00 10.3 1 13.3 7.2 10.4 1.1 13.3 5.7 10.3 1 13 7.2 340 6 347 165 1.6 0 1.8 1.4 03/25/2006 14:20:00 10.4 1 13.7 8 10.3 1.3 14.1 5.3 10.2 1.1 13.3 7.6 341 7 325 165 1.8 0 1.8 1.6 03/25/2006 14:30:00 10.7 0.9 13.3 8.4 10.7 1.1 13.7 8 10.6 1 13.3 7.2 340 7 343 165 1.7 0.1 1.8 1.4 03/25/2006 14:40:00 10.4 1.1 14.1 8.4 10.5 1.1 14.9 7.2 10.6 1 14.1 8 338 7 349 165 1.4 0.1 1.6 1.4 03/25/2006 14:50:00 10.6 1.2 13.7 7.2 10.6 1.3 14.1 7.6 10.5 1.4 14.5 7.6 335 8 338 165 1.4 0 1.6 0.9 03/25/2006 15:00:00 12.1 1.3 17.2 7.6 12 1.3 17.2 7.6 12 1.5 16.8 7.6 335 9 349 165 1.4 0 1.8 1.4 03/25/2006 15:10:00 11.3 1.3 15.6 7.6 11.2 1.5 16.4 7.2 11.4 1.5 16.1 7.2 336 8 339 165 1.3 0 1.4 1.4 03/25/2006 15:20:00 11 1.4 15.3 6.5 11.1 1.5 15.6 6.5 10.9 1.6 14.9 6.1 335 9 339 165 1.2 0 1.4 0.9 03/25/2006 15:30:00 10 1.5 13.7 6.1 9.7 1.5 13.3 5.3 9.7 1.6 13 5.7 336 12 327 165 1.2 0 1.4 0.9 03/25/2006 15:40:00 8.8 1.1 11.5 5.7 8.5 1.3 12.6 4.9 8.7 1.2 11.5 5.7 340 12 348 165 1.4 0 1.6 1.4 03/25/2006 15:50:00 10.4 1.3 14.1 7.2 10.4 1.4 14.9 7.2 10.4 1.3 14.9 6.8 338 8 347 165 1.2 0 1.4 1.1 03/25/2006 16:00:00 10.3 1.3 13.7 6.5 9.9 1.5 13.3 5.7 10.2 1.3 13.3 6.5 340 10 354 165 1.1 0 1.4 0.9 03/25/2006 16:10:00 10.7 1.5 15.3 6.5 10.5 1.9 14.9 4.6 10.7 1.5 14.9 6.5 341 9 339 165 1.2 0 1.4 0.9 03/25/2006 16:20:00 10.9 1.5 14.5 6.5 10.7 1.7 15.6 6.5 10.8 1.5 14.5 6.5 341 9 342 165 1.3 0.1 1.4 0.9 03/25/2006 16:30:00 11.1 1.1 14.1 7.2 10.8 1.7 14.1 5.3 11.1 1.2 14.5 6.8 340 9 340 165 0.9 0.1 1.4 0.4 03/25/2006 16:40:00 11.9 1.1 14.9 8.8 11.9 1.2 14.9 8.8 11.9 1.3 15.6 8.4 336 8 334 165 0.8 0.1 0.9 0.2 03/25/2006 16:50:00 10.4 1.2 13.7 8 10.2 1.3 13.7 6.5 10.3 1.3 13.3 7.2 336 10 343 165 1.1 0 1.4 0.4 03/25/2006 17:00:00 11.6 1.4 15.3 8 11.6 1.5 15.3 6.8 11.5 1.5 14.5 7.2 337 7 339 165 1 0.1 1.4 0.2 03/25/2006 17:10:00 11.8 1.2 14.9 8.8 11.8 1.3 15.3 8 11.5 1.3 14.9 8.4 335 7 343 165 1 0 1.1 0.4 03/25/2006 17:20:00 11.2 1.3 14.1 8 11.1 1.6 15.3 5.3 11 1.5 14.5 6.8 335 9 341 165 1 0 1.4 0.7 03/25/2006 17:30:00 10.8 1.3 13.7 7.2 10.6 1.5 14.1 6.1 10.5 1.6 14.5 5.7 337 10 337 165 1 0 1.4 0.7 03/25/2006 17:40:00 10.9 1.4 14.5 7.2 10.8 1.6 14.9 6.1 10.4 1.5 14.5 6.8 335 8 335 165 1.1 0 1.4 0.7 03/25/2006 17:50:00 11.6 1.6 14.9 6.1 11.5 1.6 15.3 6.5 11.2 1.7 14.9 6.5 334 9 334 165 0.9 0 1.1 0.7 03/25/2006 18:00:00 10.9 1.4 14.1 7.6 11 1.5 14.5 7.6 10.7 1.5 14.9 6.8 334 6 340 165 0.9 0 1.1 0.9 03/25/2006 18:10:00 10.5 1.2 13.3 7.6 10.5 1.3 13.7 6.5 10.5 1.2 14.1 6.8 335 8 333 165 0.8 0 0.9 0.7 03/25/2006 18:20:00 11.1 1.5 15.3 7.2 10.9 1.5 14.5 7.2 10.9 1.5 15.3 7.2 334 9 348 165 0.8 0 0.9 0.7 03/25/2006 18:30:00 11.5 1.2 16.4 8.4 11.5 1.3 16.1 8.4 11.5 1.3 15.6 7.6 335 8 338 165 0.7 0 0.9 0.7 03/25/2006 18:40:00 11.2 1.3 13.7 7.6 11.2 1.3 14.5 8 11 1.4 14.5 8 333 8 340 165 0.6 0 0.7 0.4 03/25/2006 18:50:00 12.9 1.4 16.8 9.1 12.9 1.5 16.8 8.4 13 1.4 16.4 8.4 337 8 338 165 0.7 0 0.9 0.7 03/25/2006 19:00:00 13 1.2 16.1 9.5 13 1.3 16.4 9.1 12.9 1.3 16.8 9.1 334 7 331 165 0.6 0 0.9 0.7 03/25/2006 19:10:00 12.9 1.6 16.8 6.8 12.8 1.7 17.2 7.2 12.8 1.5 16.1 6.8 336 9 333 165 0.5 0 0.7 0.4 03/25/2006 19:20:00 12.7 1.7 17.2 8.8 12.8 1.9 17.9 8 12.6 1.9 16.8 8.4 337 8 339 165 0.5 0 0.7 0.2 03/25/2006 19:30:00 13.4 1.6 18.3 9.1 13.6 1.7 18.7 8.8 13.3 1.6 19.1 9.1 336 7 341 165 0.5 0 0.7 0.2 03/25/2006 19:40:00 12.7 1.5 15.6 9.5 12.6 1.5 16.4 9.1 12.5 1.5 16.8 8 336 9 325 165 0.5 0 0.7 0.4 03/25/2006 19:50:00 13.6 1.2 16.8 9.5 13.7 1.3 16.8 8.8 13.6 1.3 17.6 10.3 337 7 333 165 0.5 0 0.7 0.4 03/25/2006 20:00:00 12.3 1.7 17.2 6.5 12.3 1.9 17.2 4.6 12.1 1.7 16.8 7.2 337 8 333 165 0.4 0 0.7 0.2 03/25/2006 20:10:00 12.1 1.5 16.4 7.6 11.8 1.6 15.6 7.6 12 1.7 15.3 6.8 335 11 351 165 0.4 0 0.7 0.2 03/25/2006 20:20:00 11.8 1.6 16.4 8 11.6 1.7 16.4 6.8 11.7 1.7 16.8 8 341 9 328 165 0.4 0 0.7 0.2 03/25/2006 20:30:00 10.5 2 14.5 5.7 10.1 1.9 14.5 5.3 10.8 1.7 14.5 6.8 342 9 347 165 0.5 0 0.7 0.2 03/25/2006 20:40:00 10.6 1.7 14.9 5.7 10.4 1.8 15.6 5.7 10.5 1.9 15.3 5.7 338 9 350 165 0.4 0 0.7 0.2 03/25/2006 20:50:00 11.1 1.6 14.9 7.2 10.4 1.9 14.9 4.9 11.6 1.7 16.8 7.6 344 9 351 165 0.3 0 0.7 0.2 03/25/2006 21:00:00 11.5 1.5 14.9 6.8 10.7 1.9 15.3 5.3 11.7 1.7 14.9 8 344 10 334 165 0.3 0 0.7 0.2 03/25/2006 21:10:00 9.4 1.4 13.3 6.5 9 1.6 13.3 4.2 9.6 1.4 14.5 6.1 341 11 350 165 0.3 0 0.7 0.2 03/25/2006 21:20:00 11.2 1.6 16.4 7.6 10.8 1.8 15.6 6.1 11.3 1.7 17.2 6.5 340 10 345 165 0.2 0 0.4 0.2 03/25/2006 21:30:00 12 1.3 16.4 8.4 12 1.5 16.8 8 12.3 1.3 16.1 8.4 339 8 340 165 0.4 0 0.7 0.2 03/25/2006 21:40:00 12 1.3 15.3 9.1 12 1.5 15.6 7.2 12.3 1.5 16.4 8.8 340 8 344 165 0.6 0 0.9 0.4 03/25/2006 21:50:00 11.7 1.8 16.4 4.9 11.1 2 17.2 5.3 11.8 1.9 16.4 7.6 343 9 339 165 0.5 0 0.7 0.2 03/25/2006 22:00:00 10.8 1.5 15.3 5.7 10.3 1.7 15.3 5.3 10.6 1.6 14.9 6.5 341 11 355 165 0.5 0 0.7 0.2 03/25/2006 22:10:00 10.9 1.7 15.3 7.2 10.8 1.8 16.1 6.5 10.6 1.7 16.1 6.5 334 11 337 165 0.6 0 0.9 0.4 03/25/2006 22:20:00 12 1.3 15.3 7.6 11.9 1.4 15.3 8 11.8 1.4 15.3 7.6 334 8 330 165 0.6 0 0.9 0.4 03/25/2006 22:30:00 12.1 1.2 16.1 8.4 12.1 1.3 16.1 8.8 12 1.2 16.1 8.8 333 7 326 165 0.5 0 0.7 0.4 03/25/2006 22:40:00 11.3 1.6 16.1 7.6 11.3 1.7 16.8 6.8 10.9 1.5 16.1 8 337 9 342 165 0.6 0 0.7 0.7 03/25/2006 22:50:00 11.8 1.7 16.4 7.6 11.8 1.7 16.4 7.6 11.4 1.7 15.6 7.2 337 8 334 165 0.7 0 0.9 0.2 03/25/2006 23:00:00 10.3 1.6 14.5 6.5 9.9 1.7 14.9 4.9 9.9 1.7 14.1 5.3 337 11 350 165 0.7 0 0.9 0.7 03/25/2006 23:10:00 11.1 1.7 14.9 6.8 11.1 1.7 14.9 6.5 10.6 1.8 15.3 6.1 332 9 339 165 0.8 0 0.9 0.7 03/25/2006 23:20:00 11.6 1.6 16.1 7.6 11.5 1.7 16.4 6.5 11 1.6 14.5 5.7 335 8 351 165 0.8 0 0.9 0.7 03/25/2006 23:30:00 9.8 1.5 13.7 6.1 9.5 1.6 13 4.9 9.2 1.5 13.3 5.3 331 12 338 165 0.8 0 0.9 0.7 03/25/2006 23:40:00 10.2 1.8 14.5 5.3 10.1 1.9 14.9 4.9 9.5 2.1 14.5 4.2 333 12 345 165 0.8 0 0.9 0.7 03/25/2006 23:50:00 8.8 1.7 13 5.3 8.5 1.9 13.3 4.2 8.3 1.7 12.6 4.6 332 14 331 165 0.8 0 0.9 0.7 03/26/2006 00:00:00 10.3 1.5 14.1 6.8 10.2 1.5 14.1 6.1 9.9 1.5 14.1 6.1 333 12 341 165 0.8 0 0.9 0.7 03/26/2006 00:10:00 10.2 1.7 14.5 6.5 10.1 1.7 14.5 6.5 9.7 1.7 13.7 5.7 332 13 341 165 0.8 0 0.9 0.7 03/26/2006 00:20:00 11.1 1.3 14.5 7.2 11 1.3 14.5 7.2 10.7 1.4 14.9 7.6 332 9 320 165 0.8 0 0.9 0.7 03/26/2006 00:30:00 12 1.8 16.4 7.6 11.8 2 16.4 6.5 11.8 2.1 17.2 6.1 332 12 330 165 0.8 0 0.9 0.7 03/26/2006 00:40:00 12.1 1.8 16.8 8 11.9 2 17.2 6.5 11.9 2 16.8 7.6 335 12 332 165 0.7 0 0.9 0.7 03/26/2006 00:50:00 12.1 1.8 16.8 6.5 12 1.9 16.8 6.5 11.5 1.8 15.6 6.8 333 9 335 165 0.6 0 0.7 0.4 03/26/2006 01:00:00 12.2 2 16.4 6.1 12 2.2 17.2 6.1 11.9 2 16.8 7.2 334 12 346 165 0.5 0 0.7 0.2 03/26/2006 01:10:00 11.8 2.3 17.2 6.5 11.5 2.3 18.3 5.7 11.5 2.2 17.9 4.2 335 11 345 165 0.5 0 0.7 0.2 03/26/2006 01:20:00 12.1 1.9 17.2 8 12 2 16.8 8.4 11.7 2.2 17.9 6.5 331 11 326 165 0.7 0 0.9 0.4 03/26/2006 01:30:00 12.1 1.8 17.6 8.4 12 1.9 17.6 7.2 11.6 1.8 16.8 7.6 331 10 338 165 0.7 0 0.9 0.7 03/26/2006 01:40:00 11 1.7 15.6 6.5 11 1.8 16.4 6.1 10.6 1.7 15.3 6.5 327 9 333 165 0.6 0 0.9 0.7 03/26/2006 01:50:00 9.7 1.3 12.6 4.9 9.5 1.3 12.6 4.9 8.8 1.1 11.8 5.3 327 14 302 165 0.3 0.2 0.7 0.2 03/26/2006 02:00:00 10.5 1.2 14.1 6.5 10.4 1.2 13.7 6.5 9.9 1.5 13.7 6.1 321 12 307 165 0 0 0.2 -0.3 03/26/2006 02:10:00 9.2 1.5 13.7 4.9 9.1 1.6 14.1 4.9 8.2 1.6 12.6 3.8 321 13 339 165 -0.1 0 0.2 -0.3 03/26/2006 02:20:00 10.9 2.5 16.4 5.3 10.8 2.6 17.2 4.6 9.9 2.6 16.1 3.8 328 13 342 165 0.1 0.1 0.7 -0.3 03/26/2006 02:30:00 10.5 1.7 15.6 6.5 10.1 1.7 15.3 6.5 9.7 2 15.6 5.3 334 12 332 165 0.6 0 0.9 0.4 03/26/2006 02:40:00 8.3 1.7 12.2 4.2 8 1.7 12.2 4.2 7.4 1.6 11.5 3.8 335 14 334 165 0.7 0 0.9 0.7 03/26/2006 02:50:00 8.2 1.9 12.6 2.6 8.2 1.8 12.2 2.3 7.3 1.8 11.1 1.9 326 14 305 165 0.4 0.1 0.7 0.2 03/26/2006 03:00:00 8.8 1.5 13.3 4.6 8.7 1.5 13.3 4.6 8.1 1.6 12.6 4.2 325 13 316 165 0.2 0 0.4 0.2 03/26/2006 03:10:00 9.1 1.4 12.2 5.3 9 1.3 11.8 5.7 8 1.7 11.5 1.9 315 12 317 165 -0.2 0.1 0.2 -0.3 03/26/2006 03:20:00 8.5 1.8 13.3 4.6 8.5 1.9 14.5 4.6 7.6 2.1 13 3.4 326 15 342 165 -0.2 0.2 0.4 -0.5 03/26/2006 03:30:00 8.2 1.4 11.5 4.6 8.1 1.5 11.1 4.2 7.6 1.5 11.8 4.2 324 14 338 165 0.1 0.1 0.4 -0.3 03/26/2006 03:40:00 8.1 1.5 12.6 5.3 8 1.5 12.2 5.3 7.1 1.5 11.5 3.8 319 12 315 165 -0.3 0 -0.1 -0.5 03/26/2006 03:50:00 9.2 1.5 13 5.7 9.2 1.5 13.3 5.7 8.6 1.9 13.3 4.6 326 15 337 165 -0.3 0.1 0.2 -0.5 03/26/2006 04:00:00 9.6 1.7 13.3 4.2 9.6 1.7 13.7 3.4 8.4 1.5 12.2 2.6 316 15 324 165 -0.3 0.1 -0.1 -0.5 03/26/2006 04:10:00 11.6 1.9 16.4 5.7 11.3 2 16.4 4.9 10.8 1.8 15.6 5.7 331 13 344 165 -0.1 0.1 0.2 -0.5 03/26/2006 04:20:00 11 1.9 17.6 7.2 10.6 1.8 16.1 6.8 10.1 1.8 15.3 6.1 336 12 2 165 0.2 0 0.7 0.2 03/26/2006 04:30:00 11.1 1.8 15.3 7.2 10.9 1.9 16.1 6.8 10.3 1.8 15.6 6.8 334 11 316 165 0.4 0 0.7 0.2 03/26/2006 04:40:00 12.2 1.7 16.8 8 12.1 1.7 16.4 8 11.8 1.7 15.6 7.6 328 9 328 165 0.7 0 0.9 0.2 03/26/2006 04:50:00 13.5 1.5 17.2 9.1 13.4 1.5 16.8 9.5 13.2 1.6 17.2 8.8 327 9 322 165 0.5 0.2 0.9 0.2 03/26/2006 05:00:00 13.5 1.3 16.8 9.9 13.4 1.3 16.8 9.1 13.1 1.3 15.6 8.8 321 8 330 165 0.2 0.1 0.7 -0.1 03/26/2006 05:10:00 13.3 1.3 16.4 8.8 13 1.5 16.4 8.4 12.8 1.5 17.2 8.8 321 10 332 165 0.1 0 0.2 -0.1 03/26/2006 05:20:00 12.8 1.2 15.6 8.8 12.7 1.2 15.6 9.1 12.2 1.3 16.4 7.6 321 9 325 165 -0.2 0 -0.1 -0.3 03/26/2006 05:30:00 13 1.3 16.4 8.8 12.9 1.3 16.1 9.1 12.8 1.3 16.1 9.5 326 8 329 165 0.2 0.2 0.7 -0.3 03/26/2006 05:40:00 12.4 1.4 16.1 9.1 12.3 1.4 15.6 8.4 11.8 1.5 16.4 8.4 323 10 325 165 0.3 0.2 0.7 -0.1 03/26/2006 05:50:00 12.4 1.7 16.4 8.4 12.2 1.7 17.2 7.6 11.9 1.8 16.1 7.6 325 9 341 165 0.1 0 0.7 -0.1 03/26/2006 06:00:00 13.6 1.5 17.2 9.9 13.5 1.7 17.9 9.9 13.2 1.7 17.9 8.8 329 9 334 165 0.7 0.2 1.1 0.2 03/26/2006 06:10:00 10.9 1.7 16.4 6.8 10.8 1.6 16.4 6.8 10.1 1.8 16.1 6.1 327 10 338 165 0.5 0 0.9 0.2 03/26/2006 06:20:00 11 1.4 15.3 7.2 10.8 1.5 15.6 6.8 10.2 1.5 14.5 6.5 337 9 334 165 0.8 0 0.9 0.4 03/26/2006 06:30:00 10.6 1.9 16.1 5.7 10.3 2 15.6 4.9 10 1.9 15.3 5.7 338 10 352 165 0.6 0.1 0.9 0.2 03/26/2006 06:40:00 12.4 1.5 16.4 8.8 12 1.8 17.2 6.8 12.1 1.5 15.3 7.6 341 9 342 165 0.7 0 0.9 0.7 03/26/2006 06:50:00 12.3 1.5 16.4 8 12 2 16.1 6.1 11.9 1.7 16.1 6.8 343 7 346 165 0.9 0 1.1 0.7 03/26/2006 07:00:00 10.9 1.7 15.6 6.8 10.6 1.9 15.3 5.3 10.8 1.8 16.1 6.1 342 8 350 165 0.9 0 1.1 0.7 03/26/2006 07:10:00 9.3 1.7 13.7 4.9 8.8 1.8 14.5 4.6 8.7 1.7 13.3 4.6 343 9 338 165 0.9 0 1.1 0.9 03/26/2006 07:20:00 9.2 1.5 13 5.3 8.6 1.6 13 4.9 9 1.5 11.8 4.6 340 12 4 165 0.9 0 1.1 0.9 03/26/2006 07:30:00 10.8 1.7 15.6 7.2 10.4 1.9 14.9 5.3 10.4 1.6 15.3 6.8 338 10 328 165 1 0 1.4 0.9 03/26/2006 07:40:00 10.1 1.2 13.3 7.2 9.5 1.5 13.3 5.3 9.6 1.3 13.7 6.1 340 12 358 165 1.2 0 1.4 0.9 03/26/2006 07:50:00 10.3 1.7 14.1 5.7 10.1 1.8 13.7 5.3 10.2 1.7 14.5 6.5 336 11 333 165 1.4 0 1.6 1.4 03/26/2006 08:00:00 9.8 2.2 14.9 4.9 9.4 2.2 14.9 4.2 9.5 2.1 14.5 4.9 334 11 331 165 1.7 0.2 2.1 1.4 03/26/2006 08:10:00 10.5 1.9 15.3 6.5 10.3 2 15.3 5.7 10.3 1.9 14.9 6.5 333 12 333 165 1.8 0 2.1 1.6 03/26/2006 08:20:00 9.8 1.7 14.5 6.1 9.5 1.9 14.5 3.8 9.7 1.6 14.9 6.1 334 12 333 165 1.8 0.1 1.8 1.6 03/26/2006 08:30:00 10 1.2 13 6.5 9.8 1.3 13 6.1 9.9 1.3 12.6 6.5 331 11 342 165 1.5 0.1 1.8 1.4 03/26/2006 08:40:00 10.1 1.3 13.7 6.8 9.9 1.6 14.5 5.7 10 1.3 13.7 7.2 338 9 344 165 2.1 0 2.3 1.8 03/26/2006 08:50:00 11.5 1.3 15.3 8.4 11.4 1.7 15.3 6.1 11.7 1.4 15.3 8.8 339 9 328 165 2.1 0 2.3 1.8 03/26/2006 09:00:00 11.6 1.5 15.3 6.8 11 1.9 15.6 6.5 11.6 1.6 15.3 7.6 341 11 340 165 2.1 0.1 2.3 1.8 03/26/2006 09:10:00 11.7 1.2 15.3 8.4 11 1.7 15.3 6.5 11.7 1.2 14.1 8.4 344 8 338 165 1.9 0 2.1 1.8 03/26/2006 09:20:00 10.5 1.8 15.3 6.8 10.2 2.2 15.6 4.6 10.1 1.7 15.3 6.8 339 9 340 165 2 0 2.3 1.8 03/26/2006 09:30:00 11 1.7 15.3 6.8 10.6 2 15.6 5.3 10.7 1.7 15.6 5.3 338 12 336 165 2 0.1 2.3 1.8 03/26/2006 09:40:00 10.1 1.5 13.7 6.1 9.9 1.7 13.7 4.9 10 1.6 13.3 6.1 337 10 330 165 1.9 0 2.1 1.8 03/26/2006 09:50:00 8.9 1.2 11.5 6.1 8.8 1.2 11.5 6.1 8.3 1.2 12.2 5.3 327 11 330 165 2.1 0 2.3 1.8 03/26/2006 10:00:00 9.8 1.7 14.9 4.6 9.7 1.7 14.9 4.2 9.6 1.7 13.7 4.6 334 8 332 165 2.9 0.2 3.3 2.3 03/26/2006 10:10:00 8.2 1.6 11.8 2.6 7.6 2 11.5 1.9 8.1 1.5 11.8 3 342 11 336 165 2.9 0.1 3.3 2.3 03/26/2006 10:20:00 9.2 1.2 12.2 6.1 9.1 1.5 12.2 5.3 9.2 1.3 13 5.7 339 9 341 165 2.7 0.3 3.3 1.8 03/26/2006 10:30:00 8.6 1.3 12.6 5.3 8.2 1.5 13 4.6 8.3 1.3 13.7 5.7 339 11 343 165 2.5 0.1 2.8 1.8 03/26/2006 10:40:00 9.8 1.7 14.5 4.9 9.3 2.1 14.1 4.6 9.6 1.6 13.7 6.1 340 12 333 165 3.2 0.3 3.8 2.3 03/26/2006 10:50:00 10.5 1.3 13.7 7.2 10.5 1.3 13.3 6.8 10 1.6 13.7 4.9 332 10 320 165 3.8 0.2 4.3 3.3 03/26/2006 11:00:00 9.1 1.6 13.3 5.7 9 1.6 13.3 4.9 8.8 1.7 13 4.9 328 13 337 165 3.5 0.4 4.3 2.8 03/26/2006 11:10:00 10.1 1.3 14.1 6.8 10 1.5 13.7 5.3 10 1.3 13.7 6.5 333 9 333 165 2.5 0.2 3 1.8 03/26/2006 11:20:00 10.8 1.8 14.9 5.3 10.7 1.8 14.9 5.7 10.5 1.9 14.5 4.6 328 14 340 165 2.3 0.1 2.6 1.8 03/26/2006 11:30:00 9.5 1.6 13.7 4.6 9.3 1.7 13.3 4.6 9 1.9 12.6 4.2 334 11 330 165 2.7 0.2 3.3 1.8 03/26/2006 11:40:00 9 1.1 12.6 6.8 8.7 1.5 13 4.2 8.7 1 11.8 5.3 339 11 344 165 3.2 0.3 3.5 2.6 03/26/2006 11:50:00 9.5 1.3 12.2 5.3 9.3 1.6 12.6 4.9 9.3 1.4 12.6 5.7 339 9 346 165 2.8 0 3.3 2.6 03/26/2006 12:00:00 10.2 1.3 13.3 6.8 10 1.6 13.3 5.3 10 1.5 13.7 6.1 339 10 332 165 3 0.1 3.3 2.8 03/26/2006 12:10:00 9.7 1.5 13.7 5.7 9.5 1.7 13.3 4.2 9.5 1.5 14.1 6.1 339 9 336 165 2.9 0 3.3 2.6 03/26/2006 12:20:00 10.1 1.2 14.1 6.5 10.1 1.2 14.9 7.2 10.1 1.3 13.7 6.8 332 9 338 165 3.4 0.4 4.3 2.8 03/26/2006 12:30:00 10.7 1.5 13.3 7.2 10.6 1.6 14.1 6.8 10.7 1.7 14.5 6.1 334 8 336 165 3.4 0.3 4.5 2.8 03/26/2006 12:40:00 11.4 1.6 14.9 7.2 11.4 1.6 14.5 6.8 11.2 1.7 15.6 6.8 334 8 334 165 3 0.2 3.8 2.6 03/26/2006 12:50:00 11.4 1.5 15.3 7.2 11.2 1.7 14.9 6.5 11.3 1.7 16.8 7.6 335 9 347 165 3.4 0.1 3.8 3 03/26/2006 13:00:00 10.2 1.6 14.5 5.7 10.2 1.6 14.1 6.1 10 1.5 13.7 6.1 335 8 352 165 3.8 0.1 4.3 3.3 03/26/2006 13:10:00 9.9 1.4 13.3 6.5 9.9 1.5 13.7 4.6 9.6 1.4 13 5.7 336 8 344 165 4.6 0.5 5.5 3.8 03/26/2006 13:20:00 9.5 1.1 12.6 6.1 9.4 1 12.2 6.1 9.2 1 12.2 6.1 331 8 332 165 4.9 0.3 5.7 4.3 03/26/2006 13:30:00 9.5 1.2 12.6 6.5 9.1 1.6 12.2 4.2 9.2 1.2 11.8 5.3 337 9 332 165 4.8 0.3 5.5 4.3 03/26/2006 13:40:00 9.6 1.3 13 4.9 9.2 1.8 13 4.6 9.7 1.3 13.3 4.6 339 11 325 165 4.7 0.3 5.5 4.3 03/26/2006 13:50:00 8.9 1.3 11.8 5.7 8.7 1.6 11.5 4.6 8.8 1.2 12.2 5.3 337 11 329 165 4.8 0.2 5.2 4.3 03/26/2006 14:00:00 9.9 1 12.6 6.8 10 1.1 12.6 6.8 10 1.1 13.3 7.2 338 8 338 165 4.4 0 5 4.3 03/26/2006 14:10:00 9.1 1.1 11.8 6.1 9 1.2 11.8 5.3 9.2 1.3 12.2 6.5 339 9 331 165 4.4 0.1 5 4 03/26/2006 14:20:00 8.6 0.8 11.1 6.8 8.2 1.2 11.1 4.2 8.5 0.8 10.7 5.7 340 13 347 165 5.4 0.5 6 4.3 03/26/2006 14:30:00 9.5 1.2 12.6 6.1 9.5 1.3 12.2 6.1 9.4 1.3 12.6 6.5 336 9 328 165 4.9 0.2 5.7 4.5 03/26/2006 14:40:00 9.8 1.1 12.2 6.8 9.8 1.2 12.2 6.5 9.6 1.2 12.6 6.5 338 7 330 165 4.8 0.1 5 4.5 03/26/2006 14:50:00 9.8 1.1 12.2 6.8 9.8 1.1 12.2 6.5 9.7 1 12.2 6.8 335 8 343 165 4.6 0.5 5.2 3.5 03/26/2006 15:00:00 9.6 1.3 13 6.5 9.4 1.6 13.3 4.9 9.9 1.3 12.6 6.5 340 9 343 165 3.2 0.2 3.8 2.8 03/26/2006 15:10:00 8.8 1 11.8 6.5 8.8 1 11.5 5.7 8.9 1.1 11.5 6.5 334 9 326 165 3.3 0 3.5 3 03/26/2006 15:20:00 7.9 1 10.7 5.7 7.9 1 11.5 4.9 7.8 0.9 9.9 5.3 335 9 332 165 4.1 0.2 4.5 3.5 03/26/2006 15:30:00 9.7 1.2 12.6 6.8 9.1 1.6 12.6 5.3 9.7 1.5 13.3 6.1 343 9 351 165 4 0.1 4.5 3.3 03/26/2006 15:40:00 8.5 1 11.8 6.1 7.9 1.4 11.1 4.6 8.7 1.1 11.8 6.1 344 10 343 165 3.8 0.2 4.3 2.8 03/26/2006 15:50:00 9.2 1.3 12.2 6.1 9.2 1.4 13 5.7 9.4 1.3 12.6 6.5 340 8 344 165 2.9 0.3 3.5 2.3 03/26/2006 16:00:00 10.1 0.9 12.6 8 9.8 1.5 13 5.7 10 1 12.6 7.2 344 6 342 165 2.8 0 2.8 2.3 03/26/2006 16:10:00 10.6 0.9 13.3 6.8 10.2 1.3 14.5 6.1 10.8 1 13.3 8 341 9 333 165 2.4 0.1 2.8 2.3 03/26/2006 16:20:00 9.1 1.2 13.7 5.7 9.1 1.4 14.1 4.9 9.2 1.2 13.3 6.1 339 9 336 165 2.3 0.1 2.6 2.1 03/26/2006 16:30:00 9.3 1 11.8 6.5 9.4 1.2 12.6 4.9 9.2 1 11.8 6.5 339 7 351 165 2.4 0 2.6 2.3 03/26/2006 16:40:00 9.2 1.2 12.2 6.5 8.9 1.8 13 3.4 9.4 1.2 13 6.8 342 8 336 165 2.3 0 2.6 2.1 03/26/2006 16:50:00 9.3 1 11.5 5.7 9.3 1.2 11.8 5.7 9.5 1.1 11.8 4.6 339 8 343 165 2.3 0 2.6 2.1 03/26/2006 17:00:00 9.7 1 11.8 6.5 9.8 1 12.2 6.5 9.6 1.1 11.8 6.1 335 7 335 165 2.6 0 2.8 2.3 03/26/2006 17:10:00 9.7 1.2 12.6 6.1 9.9 1.2 12.6 6.5 9.7 1.3 12.6 6.8 338 5 338 165 2.6 0 2.8 2.6 03/26/2006 17:20:00 10.5 0.9 12.6 7.2 10.5 1.2 13.3 6.1 10.4 1 12.6 7.2 339 7 339 165 3.1 0.3 3.8 2.6 03/26/2006 17:30:00 11.1 1.1 14.1 8.8 11.1 1.3 14.1 6.8 11.3 1.1 14.1 8.4 342 6 341 165 3.6 0.2 4 3 03/26/2006 17:40:00 10.6 1.1 13.7 8 10.7 1.2 14.5 7.6 10.7 1 13.3 8.4 334 8 346 165 3 0.3 3.8 2.6 03/26/2006 17:50:00 9.7 1.3 13.3 5.7 9.3 1.9 13.3 4.6 9.6 1.4 13 6.5 338 11 340 165 2.3 0.2 2.8 1.8 03/26/2006 18:00:00 9.6 1 12.2 7.2 9.5 1.3 13 4.6 9.7 1 12.6 7.2 337 11 338 165 2.3 0.1 2.8 1.8 03/26/2006 18:10:00 9.7 0.8 12.2 7.6 9.7 1.2 12.2 4.9 9.6 0.8 11.8 6.8 336 8 332 165 2.3 0.2 2.8 1.6 03/26/2006 18:20:00 10.1 1 13 7.2 10.2 1.1 13 7.2 10.1 1.1 13.7 7.2 337 6 336 165 2 0 2.3 1.6 03/26/2006 18:30:00 9 1.2 13.3 5.7 9 1.3 13.3 4.9 8.8 1.3 13.3 5.7 336 8 339 165 2 0 2.3 1.8 03/26/2006 18:40:00 9.9 1.1 13.3 6.5 9.9 1.1 13.3 6.8 9.9 1.1 12.6 6.5 329 9 332 165 2.1 0 2.3 1.8 03/26/2006 18:50:00 9.7 1.3 13.3 6.5 9.7 1.3 13.3 6.1 9.4 1.3 13.3 6.5 334 9 351 165 2.1 0 2.3 1.8 03/26/2006 19:00:00 10.9 1 13 8.4 10.8 1.1 13.3 6.1 10.9 1 14.5 8.4 334 9 329 165 2.2 0 2.3 1.8 03/26/2006 19:10:00 10.3 1.2 14.1 7.2 10.4 1.3 14.1 6.5 10.4 1.3 13.7 7.2 338 9 340 165 2.1 0.1 2.6 1.6 03/26/2006 19:20:00 10.4 0.8 13 8.4 10.6 0.9 13.7 8.4 10.3 0.9 14.5 8 339 6 342 165 1.9 0 2.1 1.6 03/26/2006 19:30:00 10.8 1.1 13.7 8 10.9 1.1 13.7 7.2 10.9 1.2 13.7 8.4 335 6 339 165 1.8 0 1.8 1.6 03/26/2006 19:40:00 10.4 1 13 7.2 10.4 1.1 13.3 6.8 10.3 1 13.3 7.2 338 8 341 165 1.9 0 1.8 1.8 03/26/2006 19:50:00 9.7 1 12.2 6.8 9.5 1.3 12.6 4.9 9.7 1.1 12.6 6.5 340 9 341 165 1.8 0 1.8 1.6 03/26/2006 20:00:00 10.3 1 12.6 7.2 10.3 1.3 12.6 5.3 10.4 1.1 12.6 6.5 338 8 338 165 1.7 0 1.8 1.6 03/26/2006 20:10:00 10.4 1.1 13.3 7.2 10.6 1.3 13.3 6.1 10.5 1.2 13.3 7.2 338 7 339 165 1.7 0 1.8 1.4 03/26/2006 20:20:00 9.3 1 12.6 6.5 9 1.4 12.2 4.6 9.3 1.1 13 6.5 341 10 337 165 1.8 0 1.8 1.4 03/26/2006 20:30:00 8.7 1 11.1 5.7 8.2 1.5 11.8 4.2 8.5 1.1 12.2 5.7 344 9 334 165 1.7 0 1.8 1.1 03/26/2006 20:40:00 8.9 1 11.1 6.5 8.8 1.3 11.1 4.2 8.8 1 11.1 6.5 340 7 332 165 1.6 0 1.8 1.1 03/26/2006 20:50:00 8.4 0.9 12.6 5.7 8.1 1 12.2 5.3 8.2 1 11.5 5.7 337 10 330 165 1.5 0 1.6 0.9 03/26/2006 21:00:00 9.4 1 12.6 6.8 9 1.5 12.6 4.6 9.4 1.1 13 7.2 340 10 337 165 1.5 0 1.6 1.1 03/26/2006 21:10:00 8.7 0.9 11.5 6.5 8.5 1.1 11.5 5.3 8.7 1 11.1 6.5 339 9 333 165 1.5 0 1.6 1.1 03/26/2006 21:20:00 9.1 1.5 12.6 5.7 9.1 1.5 12.6 5.7 9.1 1.4 12.2 6.1 334 9 330 165 1.7 0.1 2.1 1.4 03/26/2006 21:30:00 9.6 0.9 12.6 7.6 9.4 1.3 12.6 4.6 9.7 1 13 7.2 341 8 331 165 1.9 0.1 2.1 1.4 03/26/2006 21:40:00 9.1 0.9 11.5 6.8 9.1 1 11.1 6.8 9.1 0.9 11.8 6.8 333 7 326 165 1.8 0 1.8 1.6 03/26/2006 21:50:00 8.9 0.9 12.2 6.5 9 1 12.2 6.5 8.9 0.9 12.2 6.1 336 7 340 165 1.7 0 1.8 1.6 03/26/2006 22:00:00 9.2 1.1 12.2 6.8 8.9 1.7 13 4.6 9.4 1.1 12.2 7.2 344 7 340 165 1.7 0 1.8 1.6 03/26/2006 22:10:00 9.1 0.8 11.1 7.2 8.8 1.3 11.8 4.2 9.3 0.9 11.5 7.2 343 7 343 165 1.7 0 1.8 1.6 03/26/2006 22:20:00 8.9 0.9 11.1 6.8 8.7 1.2 11.1 4.9 9 1 11.1 6.5 342 7 332 165 1.7 0 1.8 1.6 03/26/2006 22:30:00 8.2 0.8 10.7 6.5 7.4 1.2 9.9 4.2 8.5 0.9 11.5 6.8 346 8 354 165 1.8 0 1.8 1.6 03/26/2006 22:40:00 8.6 0.8 11.8 6.5 8.2 1.2 13 4.9 8.7 0.8 11.5 6.1 345 6 344 165 1.7 0 1.8 1.6 03/26/2006 22:50:00 7.2 0.8 9.5 5.3 6.2 1.5 9.9 3 7.3 0.8 9.9 5.3 349 7 338 165 1.7 0 1.8 1.4 03/26/2006 23:00:00 8.3 1 10.7 5.7 8.1 1.3 11.1 3.4 8.2 1 10.7 5.3 341 8 339 165 1.7 0 1.8 1.4 03/26/2006 23:10:00 8 1.1 11.1 4.9 7.5 1.6 11.5 3.4 8.2 1 11.1 5.7 346 7 337 165 1.9 0 2.1 1.6 03/26/2006 23:20:00 7.5 0.9 9.9 4.2 6.9 1.5 9.9 3.4 7.7 0.9 9.9 5.3 346 8 347 165 1.8 0 1.8 1.8 03/26/2006 23:30:00 7.3 0.7 9.5 5.3 6 1.5 9.5 3 7.4 0.7 9.5 5.7 351 8 352 165 1.8 0 2.1 1.6 03/26/2006 23:40:00 6.4 0.6 8 4.6 5.6 1.3 8.4 2.6 6.6 0.6 8 4.9 348 9 343 165 1.9 0 2.1 1.8 03/26/2006 23:50:00 6.9 1 9.5 4.6 5.8 1.5 9.1 2.6 6.9 1 9.9 4.9 349 6 349 165 1.9 0 2.1 1.8 03/27/2006 00:00:00 8.1 1 9.9 5.7 6.9 1.7 10.7 3.4 8.1 1 10.3 6.1 350 7 342 165 1.8 0 1.8 1.6 03/27/2006 00:10:00 7.7 1 10.3 5.3 6.7 1.5 10.3 3.4 7.8 1.1 10.3 4.9 349 8 354 165 1.7 0 1.8 1.6 03/27/2006 00:20:00 7.4 1.2 10.3 3.8 7.2 1.5 10.7 3.4 7.4 1.3 11.5 4.9 340 8 339 165 1.8 0 1.8 1.6 03/27/2006 00:30:00 6.7 1.1 9.1 4.2 6.4 1.4 9.1 2.6 6.8 1.1 8.8 4.2 343 9 341 165 2 0 2.1 1.8 03/27/2006 00:40:00 5.8 1.3 9.1 3.8 5.1 1.6 9.9 2.3 5.8 1.2 9.1 3.8 346 10 340 165 2 0 2.3 1.8 03/27/2006 00:50:00 6.2 1 8.4 4.2 6.1 1.1 8.8 3 6.3 0.9 8.8 4.6 334 11 338 165 2 0.1 2.3 1.8 03/27/2006 01:00:00 6.4 0.8 8.4 4.2 6.4 0.9 8.4 2.6 6.5 0.8 8.4 3.4 340 7 336 165 2.4 0 2.6 2.3 03/27/2006 01:10:00 4.9 0.7 6.8 3 4.3 1.1 6.8 1.9 5.1 0.7 7.2 3.8 343 10 330 165 2.4 0 2.6 2.3 03/27/2006 01:20:00 5.5 0.7 7.2 3.4 5 1.1 6.8 2.3 5.6 0.6 6.8 3.8 343 11 351 165 2.4 0 2.6 2.3 03/27/2006 01:30:00 4.3 0.7 6.1 2.6 3.5 0.8 5.3 1.1 4.4 0.6 6.1 3 348 8 347 165 2.4 0 2.6 2.3 03/27/2006 01:40:00 4.2 0.6 5.7 2.6 3.9 0.8 5.7 1.9 4.3 0.6 6.1 1.9 340 11 4 165 2.4 0 2.6 2.3 03/27/2006 01:50:00 4.2 0.8 6.1 2.6 3.9 1.1 6.1 1.1 4.3 0.7 6.1 2.6 342 8 334 165 2.4 0 2.6 2.3 03/27/2006 02:00:00 5 0.6 6.5 3.4 4.8 0.7 7.2 2.6 5.1 0.6 7.2 3 343 6 347 165 2.4 0 2.6 2.3 03/27/2006 02:10:00 4.2 0.4 5.3 3 2.7 0.8 4.9 1.1 4.3 0.5 5.7 3.4 357 7 10 165 2.3 0 2.3 2.1 03/27/2006 02:20:00 4.4 0.4 6.1 3.4 2.8 1 5.7 1.1 4.6 0.4 5.7 3.8 356 7 351 165 2.3 0 2.6 2.3 03/27/2006 02:30:00 3.9 0.4 4.9 3 3.1 0.7 4.9 1.5 4.1 0.5 4.9 2.6 350 6 356 165 2.4 0 2.6 2.3 03/27/2006 02:40:00 4.1 0.5 5.3 3 3.9 0.8 5.3 1.5 4.3 0.4 5.7 3.4 339 7 340 165 2.4 0 2.6 2.3 03/27/2006 02:50:00 5 0.6 6.5 3.4 5 0.7 6.5 2.6 5.2 0.5 6.5 3.4 341 5 349 165 2.5 0 2.8 2.3 03/27/2006 03:00:00 5.7 0.5 7.2 4.6 5.6 0.6 6.8 3 5.8 0.5 7.2 4.2 342 5 349 165 2.6 0 2.8 2.3 03/27/2006 03:10:00 5.6 0.7 6.8 3.4 4.9 0.8 6.5 2.6 5.7 0.6 7.2 3.4 346 8 353 165 2.6 0 2.8 2.6 03/27/2006 03:20:00 5.6 0.7 7.6 3.8 4.8 1.1 7.2 1.9 5.7 0.7 8 3.4 349 8 355 165 2.3 0 2.6 2.1 03/27/2006 03:30:00 5.2 0.7 6.5 3.8 4.5 1.2 6.5 1.5 5.3 0.6 6.8 3.8 347 9 338 165 2.1 0 2.3 1.8 03/27/2006 03:40:00 5.5 0.6 7.2 4.2 4.4 1.3 7.2 1.9 5.5 0.6 7.2 4.2 350 8 343 165 2 0 2.3 1.8 03/27/2006 03:50:00 4.8 0.6 6.5 3 3.6 0.8 5.3 1.9 5 0.7 6.5 3.4 352 9 352 165 2.1 0 2.3 1.8 03/27/2006 04:00:00 4.7 0.5 5.7 2.3 3.6 0.9 5.7 1.5 4.9 0.4 6.1 3.4 351 7 1 165 2.1 0 2.3 1.8 03/27/2006 04:10:00 4.6 0.5 5.7 3 3.3 1 5.7 1.5 4.8 0.5 6.1 3 353 6 355 165 2 0 2.3 1.8 03/27/2006 04:20:00 4.5 0.4 5.3 3.4 3.7 0.7 4.9 1.5 4.7 0.4 5.7 3.8 348 5 350 165 2 0.1 2.3 1.8 03/27/2006 04:30:00 4.7 0.5 6.1 3.4 3.8 0.8 6.1 1.5 4.9 0.6 6.5 3.4 349 6 351 165 2.1 0 2.3 1.8 03/27/2006 04:40:00 4.8 0.6 6.5 3.4 3.9 1 6.1 1.9 4.9 0.5 6.5 3.8 348 8 357 165 2 0 2.3 1.8 03/27/2006 04:50:00 4.9 0.5 6.1 3.8 3.2 1 6.5 1.9 5.2 0.4 6.1 4.2 354 5 349 165 2.1 0 2.3 1.8 03/27/2006 05:00:00 5.2 0.5 6.8 3.8 3.7 0.8 6.5 1.9 5.4 0.5 6.8 4.2 353 5 358 165 2.2 0 2.3 2.1 03/27/2006 05:10:00 5 0.4 6.1 3.8 4.2 1 6.1 1.5 5.3 0.4 6.1 4.2 349 6 349 165 2.1 0 2.3 1.8 03/27/2006 05:20:00 5 0.7 7.2 3.8 4.6 1 6.8 1.9 5.1 0.6 6.8 4.2 342 9 351 165 2 0 2.3 1.8 03/27/2006 05:30:00 4.9 0.4 5.7 4.2 3.9 1 5.7 1.9 5.1 0.4 6.1 4.2 350 5 349 165 2.1 0.1 2.3 1.8 03/27/2006 05:40:00 4.9 0.6 6.5 2.6 4.6 0.9 6.1 1.9 5.1 0.6 6.5 3.4 345 6 349 165 2.1 0 2.3 1.8 03/27/2006 05:50:00 4.7 0.5 5.7 3.4 4 0.8 5.7 1.9 4.8 0.5 5.7 3.4 348 6 356 165 1.9 0 2.1 1.8 03/27/2006 06:00:00 5 0.6 6.1 3.4 4.2 1.1 6.5 1.9 5.1 0.6 6.5 3.8 348 7 340 165 1.9 0 2.1 1.6 03/27/2006 06:10:00 4.7 0.5 6.1 3.4 3.9 0.8 5.7 1.9 4.9 0.5 6.5 3.8 349 7 351 165 2.1 0 2.3 1.8 03/27/2006 06:20:00 4.8 0.5 6.1 3.4 3.5 0.9 5.7 1.5 5 0.5 6.1 3.8 352 7 344 165 2.3 0 2.6 2.1 03/27/2006 06:30:00 4.7 0.6 5.7 3 3.2 0.8 5.3 1.5 4.9 0.5 6.1 3.8 353 6 351 165 2.3 0 2.6 2.3 03/27/2006 06:40:00 4.4 0.6 5.7 3 3.2 0.7 4.9 1.9 4.7 0.6 5.7 3.4 351 9 352 165 2.3 0 2.6 2.3 03/27/2006 06:50:00 4.7 0.4 5.7 3.8 3.3 1 5.7 1.9 4.9 0.4 6.1 3.8 355 8 348 165 2.4 0 2.6 2.3 03/27/2006 07:00:00 4.9 0.5 6.1 3.8 2.9 0.7 4.6 1.5 5 0.5 6.1 4.2 357 4 359 165 2.4 0 2.8 2.3 03/27/2006 07:10:00 4.6 0.4 5.3 3.4 3.3 0.7 5.3 1.5 4.7 0.4 5.7 3.4 353 4 349 165 2.9 0.1 3.3 2.6 03/27/2006 07:20:00 3.9 0.5 4.9 2.6 2.7 0.9 4.6 1.1 4.2 0.5 4.9 3 353 6 349 165 3.2 0.1 3.5 3 03/27/2006 07:30:00 4.2 0.5 5.3 2.6 3 0.7 4.6 1.5 4.5 0.5 5.7 3 354 6 3 165 3.8 0 4 3.5 03/27/2006 07:40:00 4.1 0.5 5.7 3 2.6 0.6 4.6 1.1 4.3 0.4 5.3 3 354 6 351 165 4 0 4.3 3.8 03/27/2006 07:50:00 3.9 0.5 5.3 2.6 2.6 0.9 4.9 1.1 4 0.5 5.3 3 354 7 358 165 4.3 0 4.5 4 03/27/2006 08:00:00 4.4 0.5 6.1 3.4 2.7 0.8 5.3 1.1 4.5 0.5 6.1 3.4 354 6 354 165 4.4 0 4.8 4.3 03/27/2006 08:10:00 4.4 0.6 6.1 3 2.9 0.8 4.9 1.1 4.4 0.6 6.1 3 354 7 1 165 4.7 0.1 5 4.3 03/27/2006 08:20:00 4.5 0.6 5.7 3 3.4 1.1 5.7 1.1 4.4 0.7 6.1 3 349 7 344 165 4.9 0.2 5.2 4.5 03/27/2006 08:30:00 4.7 0.5 6.1 3.4 3.4 1 5.7 1.1 4.6 0.4 5.7 3.4 352 7 349 165 5.2 0.1 5.5 4.8 03/27/2006 08:40:00 4.8 0.5 6.5 3.8 3.1 0.8 5.3 1.5 4.7 0.6 6.1 3 354 6 0 165 5.4 0.1 5.7 5 03/27/2006 08:50:00 4.3 0.6 5.7 3 3 1 5.7 1.1 4.3 0.6 5.7 3 353 11 353 165 5.9 0 6.2 5.7 03/27/2006 09:00:00 3.6 0.4 4.9 2.6 2.3 0.6 3.8 1.1 3.6 0.4 4.6 2.6 2 7 358 165 6.6 0.2 7 6 03/27/2006 09:10:00 3.7 0.4 4.6 2.6 2.4 0.6 4.2 0.7 3.6 0.5 4.6 2.3 359 8 4 165 7.1 0.1 7.5 7 03/27/2006 09:20:00 3.3 0.5 4.6 2.3 2.4 0.7 4.2 0.7 3.2 0.4 4.2 2.3 6 13 12 165 7.8 0.2 8.3 7.3 03/27/2006 09:30:00 3.9 0.5 4.9 2.6 3.5 0.7 4.6 1.5 3.8 0.6 5.3 2.3 20 12 7 165 7.4 0.6 8.5 6.7 03/27/2006 09:40:00 4.3 0.9 6.5 2.3 4.2 0.9 6.1 2.3 4.2 0.8 6.1 2.6 28 11 12 165 7.3 0.2 7.5 6.7 03/27/2006 09:50:00 3.7 0.5 4.9 2.6 3.5 0.5 4.6 1.5 3.6 0.5 4.9 2.3 23 11 16 165 7.1 0.4 8.3 6.2 03/27/2006 10:00:00 3.5 0.8 5.7 1.9 3.3 0.9 5.7 1.5 3.4 0.9 6.1 1.9 27 12 26 165 7.6 0.4 8.3 7 03/27/2006 10:10:00 2.9 0.6 4.6 1.5 2.5 0.7 4.6 1.1 2.9 0.7 4.6 1.5 16 13 31 165 7.5 0.5 8.5 6.7 03/27/2006 10:20:00 4 1 6.5 1.5 3.7 1 6.1 1.5 3.9 1 6.8 1.9 22 12 21 165 7.7 0.1 8.5 7.5 03/27/2006 10:30:00 3.4 0.6 5.3 1.9 3 0.8 5.3 1.5 3.2 0.7 5.3 1.9 16 12 27 165 7.4 0.2 8 7 03/27/2006 10:40:00 3.3 0.6 4.6 1.9 3.2 0.6 4.6 1.5 3.2 0.6 4.9 1.9 29 13 6 165 7.4 0.4 8.5 6.7 03/27/2006 10:50:00 3.3 0.8 4.9 1.1 3 0.8 4.9 1.1 3.3 0.8 4.9 1.1 17 15 12 165 7.6 0.4 8.5 7 03/27/2006 11:00:00 2.9 0.6 4.9 1.5 2.8 0.6 4.6 1.5 2.8 0.7 4.6 1.5 28 10 29 165 8.1 0.4 8.8 7.3 03/27/2006 11:10:00 2.2 0.7 3.4 0.7 2.2 0.7 3.4 0.7 2 0.8 3.4 0.4 29 12 27 165 7.6 0.3 8.3 7 03/27/2006 11:20:00 3.4 1 5.7 1.9 3.3 1 5.7 1.9 3.3 1 5.7 1.5 43 11 44 165 7.2 0.6 8.5 6.2 03/27/2006 11:30:00 3.1 0.8 4.6 0.7 3.1 0.8 4.6 0.7 3.1 0.8 4.2 0.7 50 12 48 165 6.4 0.4 7.3 5.7 03/27/2006 11:40:00 3.7 1 6.5 1.9 3.8 1 6.1 1.9 3.6 1 5.7 1.5 54 13 47 165 6.6 0.4 7.5 5.7 03/27/2006 11:50:00 3.2 0.7 5.3 1.5 3.1 0.7 5.3 1.5 2.9 0.8 4.9 1.1 25 35 37 165 7.3 0.7 8.5 6.2 03/27/2006 12:00:00 2.8 0.6 4.2 1.5 2.5 0.7 3.8 0.7 2.6 0.6 4.2 1.1 346 9 349 165 9.3 0.7 10.3 8 03/27/2006 12:10:00 3.3 0.7 4.9 1.1 3 0.8 4.9 0.7 3.2 0.7 4.9 1.1 345 9 349 165 9.6 0.1 10.1 9.3 03/27/2006 12:20:00 2.7 0.5 4.2 1.5 2.3 0.6 3.8 1.1 2.6 0.6 4.2 1.1 352 12 337 165 8.9 0.4 9.8 8.3 03/27/2006 12:30:00 2.6 0.5 3.8 1.1 2.3 0.5 3.8 0.7 2.4 0.5 3.8 1.1 351 15 348 165 8.6 0.3 9.3 8 03/27/2006 12:40:00 2.9 0.6 4.9 1.5 2.6 0.6 4.6 1.1 2.8 0.6 4.6 1.5 353 26 24 165 8.8 0.5 9.6 8 03/27/2006 12:50:00 2.4 0.7 4.2 0.7 2.1 0.6 3.8 0.4 2.2 0.8 4.2 0.4 354 27 339 165 8.9 0.3 9.6 8.3 03/27/2006 13:00:00 3.3 0.9 5.3 1.1 3.1 1 5.3 0.7 3.3 1 5.3 0.4 18 21 27 165 8.6 0.7 9.6 7.5 03/27/2006 13:10:00 4.2 0.5 5.7 2.6 4.2 0.5 5.7 2.6 4.3 0.6 5.7 2.6 28 7 25 165 6.6 0.7 8 5.5 03/27/2006 13:20:00 3.6 0.5 5.3 2.3 3.4 0.6 4.9 1.9 3.7 0.5 4.9 2.3 18 9 20 165 6.7 0.7 7.8 5.7 03/27/2006 13:30:00 3.2 0.5 4.2 1.5 3.1 0.6 4.2 1.5 3.2 0.6 4.6 1.1 35 10 33 165 6.6 0.7 7.8 5.5 03/27/2006 13:40:00 4 0.5 5.3 2.6 4 0.5 5.3 2.6 4 0.6 5.3 2.6 33 10 29 165 5.7 0.4 6.5 5.2 03/27/2006 13:50:00 3.8 0.5 5.3 2.3 3.7 0.5 4.9 1.9 3.8 0.5 4.9 1.9 30 8 37 165 6.1 0.3 6.7 5.5 03/27/2006 14:00:00 4.4 0.5 5.3 3.4 4.3 0.5 5.3 3 4.4 0.5 5.7 3.4 28 7 19 165 6.1 0.7 7 4.5 03/27/2006 14:10:00 4.8 0.3 5.7 3.4 4.8 0.4 5.7 3.4 4.9 0.4 5.7 3.4 33 5 42 165 5.7 0.4 6.7 5 03/27/2006 14:20:00 4.7 0.4 5.7 3.8 4.8 0.4 5.7 3.4 4.8 0.5 6.1 3.4 33 4 36 165 4.9 0 5.5 4.8 03/27/2006 14:30:00 4.5 0.4 5.3 3.4 4.5 0.4 5.3 3 4.5 0.5 5.3 3.4 32 6 30 165 4.8 0 5 4.8 03/27/2006 14:40:00 4.1 0.4 4.9 3 4.1 0.4 4.9 2.6 4.1 0.4 4.9 3 30 6 33 165 5.4 0.4 6 4.8 03/27/2006 14:50:00 4.6 0.6 6.5 3 4.5 0.7 6.5 2.6 4.6 0.7 6.1 3 25 7 19 165 6.1 0.2 6.7 5.7 03/27/2006 15:00:00 4.7 0.5 6.1 3.4 4.5 0.5 6.1 3 4.8 0.5 6.1 3 21 6 22 165 6.3 0.2 6.7 6 03/27/2006 15:10:00 4.3 0.5 5.3 2.6 4.3 0.6 5.7 2.6 4.3 0.6 6.1 2.6 26 8 30 165 6.1 0 6.2 5.7 03/27/2006 15:20:00 4.5 0.5 5.7 3.4 4.4 0.5 5.3 3 4.4 0.5 6.1 3 30 8 31 165 5.2 0.3 6.2 4.5 03/27/2006 15:30:00 4.8 0.5 6.1 3.8 4.7 0.6 6.1 2.6 4.7 0.5 6.1 3.4 25 6 29 165 4.9 0 5.7 4.8 03/27/2006 15:40:00 5.1 0.5 6.5 3.8 5 0.5 6.1 3.4 4.9 0.6 6.5 3.4 26 6 23 165 4.9 0 5.2 4.8 03/27/2006 15:50:00 5.4 0.8 7.2 3.4 5.3 0.8 7.6 2.3 5.2 0.8 7.2 3.4 26 9 31 165 5.1 0.1 5.5 4.8 03/27/2006 16:00:00 5.5 0.7 6.8 3.4 5.4 0.8 7.2 3.4 5.4 0.8 6.8 3.8 32 9 26 165 5.1 0.2 5.7 4.8 03/27/2006 16:10:00 5.3 0.9 7.2 3.4 5.2 1 7.2 3 5 0.8 7.6 2.6 25 11 19 165 5.6 0.2 6 5 03/27/2006 16:20:00 5.6 0.9 7.2 3.4 5.5 1 7.2 3 5.5 0.9 7.6 3.4 30 9 39 165 4.6 0.2 5.2 4.3 03/27/2006 16:30:00 5.9 0.8 7.6 3.8 5.7 0.8 7.6 3.4 5.7 0.8 8 3.8 22 8 33 165 4.8 0.4 5.5 4.3 03/27/2006 16:40:00 5.9 0.7 7.6 3.4 5.8 0.8 7.6 3.4 5.7 0.7 7.6 4.2 24 7 23 165 5.5 0 5.7 5.2 03/27/2006 16:50:00 6 0.7 7.6 3.8 6 0.8 7.2 3.8 5.9 0.8 7.6 3.8 29 6 29 165 5 0.3 5.5 4.5 03/27/2006 17:00:00 5.4 0.5 6.8 3.8 5.3 0.6 6.8 3 5.4 0.6 6.5 3.8 26 7 23 165 4.9 0.3 5.5 4.3 03/27/2006 17:10:00 4.8 0.5 6.1 3.4 4.4 0.7 5.7 2.3 4.8 0.7 6.5 3 19 8 19 165 5.5 0.2 6 5 03/27/2006 17:20:00 4.7 0.5 6.5 3.4 4.3 0.6 6.1 3 4.7 0.6 6.5 3 19 8 6 165 5.2 0.5 5.7 4.3 03/27/2006 17:30:00 4.7 0.5 6.1 3.4 4.6 0.5 6.1 3 4.6 0.5 6.1 3 31 7 29 165 4 0.3 4.5 3.5 03/27/2006 17:40:00 4.3 0.6 5.7 2.6 4.3 0.6 5.7 2.3 4.2 0.6 5.7 2.6 30 8 15 165 3.5 0 3.5 3.3 03/27/2006 17:50:00 4.1 0.6 5.3 2.3 4 0.6 5.3 2.3 4 0.5 5.3 3 26 9 27 165 3.5 0 3.5 3.3 03/27/2006 18:00:00 4.5 0.5 5.7 3.4 4.5 0.5 5.7 3.4 4.3 0.5 5.3 3 30 5 29 165 3.2 0 3.5 3 03/27/2006 18:10:00 4.3 0.5 5.7 2.6 4.3 0.5 5.7 3 4.2 0.5 5.3 3 28 7 32 165 3.3 0 3.8 3 03/27/2006 18:20:00 4.3 0.6 6.1 3 4.2 0.6 6.1 3 4.1 0.6 6.1 2.6 25 7 26 165 3.2 0 3.5 2.8 03/27/2006 18:30:00 4.4 0.5 5.3 2.6 4.2 0.6 5.3 1.9 4 0.6 5.3 2.3 22 6 26 165 3 0 3.3 2.8 03/27/2006 18:40:00 3.8 0.5 4.9 2.6 3.8 0.5 4.9 2.6 3.6 0.5 4.9 2.6 30 9 29 165 2.9 0 3.5 2.8 03/27/2006 18:50:00 3.6 0.7 5.3 2.3 3.5 0.7 4.9 1.9 3.4 0.7 4.9 1.9 28 11 32 165 2.9 0 3.5 2.8 03/27/2006 19:00:00 3.8 0.6 5.3 1.9 3.6 0.6 5.3 1.5 3.7 0.6 4.9 1.9 27 17 20 165 2.9 0 3.5 2.6 03/27/2006 19:10:00 4.1 1 6.1 1.5 4.3 1 6.5 1.9 4.1 0.8 6.1 1.9 68 15 66 165 2.4 0.1 2.8 2.3 03/27/2006 19:20:00 5.5 0.8 7.2 3.4 5.7 0.9 7.2 3.4 5.3 0.8 7.2 2.6 64 9 70 165 2.4 0.1 3 2.3 03/27/2006 19:30:00 6 0.7 7.6 4.2 6.2 0.7 7.6 4.6 5.8 0.6 7.6 4.2 73 4 73 165 2.5 0.1 3 2.3 03/27/2006 19:40:00 4.8 0.7 6.1 3 5.1 0.7 6.5 3.4 4.7 0.6 6.1 3 71 5 74 165 2.5 0.1 3 2.3 03/27/2006 19:50:00 3.8 0.5 5.3 2.6 4.1 0.5 5.3 3 3.8 0.5 4.9 2.6 77 7 77 165 2.4 0 2.8 2.3 03/27/2006 20:00:00 4 0.7 5.3 1.9 4.3 0.7 5.7 2.3 4.1 0.6 5.3 2.6 76 7 88 165 2.5 0 3 2.3 03/27/2006 20:10:00 2.6 0.6 4.2 1.5 3 0.5 4.2 1.9 2.8 0.5 4.2 1.5 60 9 72 165 2.4 0 2.6 2.3 03/27/2006 20:20:00 2.4 0.5 3.4 1.5 2.7 0.5 3.8 1.5 2.4 0.5 3.8 1.5 66 9 59 165 2.4 0 2.6 2.3 03/27/2006 20:30:00 3.1 0.3 3.8 2.6 3.4 0.2 4.2 3 3.4 0.3 3.8 2.3 91 6 81 165 2.3 0 2.8 2.1 03/27/2006 20:40:00 3.3 0.2 3.8 3 3.6 0.2 4.2 3.4 3.6 0.2 4.2 3 96 2 94 165 2.4 0.1 3 2.3 03/27/2006 20:50:00 3.4 0.2 3.8 3 3.8 0.2 4.2 3.4 3.8 0.2 4.2 3.4 86 4 92 165 2.4 0 2.6 2.3 03/27/2006 21:00:00 3 0.2 3.4 2.6 3.4 0.2 3.8 3 3.5 0.2 3.8 3 80 0 81 165 2.3 0 2.6 1.8 03/27/2006 21:10:00 2.7 0.3 3.4 2.3 3 0.3 3.8 2.6 3.2 0.2 3.8 2.6 72 7 80 165 2.1 0 2.3 1.8 03/27/2006 21:20:00 3.5 0.4 4.6 2.6 3.7 0.4 4.6 3 4.1 0.4 4.9 3.4 61 3 61 165 2.2 0 2.3 1.8 03/27/2006 21:30:00 3.6 0.2 3.8 3 3.9 0.2 4.2 3.4 4.1 0.2 4.6 3.4 64 3 61 165 2.1 0 2.3 1.8 03/27/2006 21:40:00 3.7 0.2 4.2 3.4 4 0.2 4.6 3.4 4 0.2 4.6 3.4 80 5 81 165 2.1 0 2.3 1.8 03/27/2006 21:50:00 3.3 0.3 3.8 2.6 3.7 0.3 4.2 3 3.6 0.3 4.2 3 96 4 89 165 2.2 0 2.3 2.1 03/27/2006 22:00:00 3.4 0.4 4.6 2.3 3.6 0.4 4.6 2.6 3.5 0.4 4.6 2.3 116 8 119 165 2.1 0 2.3 1.8 03/27/2006 22:10:00 3.6 0.3 4.6 2.6 3.8 0.3 4.6 3 3.9 0.3 4.9 3.4 128 7 128 165 2.1 0 2.3 1.8 03/27/2006 22:20:00 4.1 0.4 5.3 3 4.2 0.4 5.3 3 4.2 0.4 5.3 3 133 6 128 165 2.2 0 2.3 1.8 03/27/2006 22:30:00 4.4 0.4 5.7 3.4 4.5 0.4 5.7 3.8 4.6 0.4 5.7 3.8 134 5 131 165 2.3 0 2.6 2.1 03/27/2006 22:40:00 4.5 0.3 4.9 3.4 4.6 0.3 5.3 3.8 4.6 0.3 5.3 3.8 136 4 134 165 2.3 0 2.6 2.1 03/27/2006 22:50:00 4.5 0.4 5.3 3.4 4.5 0.3 5.3 3.4 4.6 0.4 5.3 3.4 143 4 147 165 2.2 0 2.3 2.1 03/27/2006 23:00:00 4.6 0.5 6.1 3.4 4.5 0.5 6.1 3.8 4.7 0.5 6.5 3.8 151 6 151 165 2.2 0 2.3 2.1 03/27/2006 23:10:00 3.9 0.5 4.9 2.3 3.8 0.5 4.9 2.6 4.1 0.6 5.7 2.3 156 6 145 165 2.2 0 2.3 2.1 03/27/2006 23:20:00 3.2 0.4 4.6 2.3 3.2 0.4 4.6 2.3 3.4 0.4 4.2 2.3 157 8 148 165 2.1 0 2.3 1.8 03/27/2006 23:30:00 3 0.5 4.2 1.9 2.9 0.5 4.2 1.9 3.3 0.4 4.2 2.3 156 9 140 165 2 0 2.3 1.8 03/27/2006 23:40:00 3 0.3 3.8 1.9 2.9 0.3 3.8 1.9 3.3 0.3 4.2 2.6 161 5 156 165 1.9 0 2.1 1.6 03/27/2006 23:50:00 2.6 0.4 3.4 1.5 2.6 0.4 3.4 1.5 2.9 0.4 3.8 1.9 159 5 158 165 1.9 0 2.1 1.6 03/28/2006 00:00:00 2.2 0.3 3 1.1 2 0.3 2.6 1.1 2.4 0.2 3 1.9 162 8 159 165 1.9 0 2.1 1.8 03/28/2006 00:10:00 1.9 0.4 2.6 0.7 1.8 0.4 2.6 0.4 2.2 0.3 3 1.5 158 6 159 165 1.8 0 1.8 1.6 03/28/2006 00:20:00 2.1 0.4 3 0.7 1.9 0.4 2.6 0.4 2.2 0.3 3 1.5 152 9 164 165 1.7 0 1.8 1.6 03/28/2006 00:30:00 1.2 0.4 2.3 0.4 0.8 0.5 2.3 0.4 1.4 0.4 2.3 0.4 135 9 137 165 1.5 0.2 1.8 0.9 03/28/2006 00:40:00 1.8 0.4 2.6 0.7 1.6 0.5 2.3 0.4 2.1 0.4 2.6 1.1 145 10 145 165 1.4 0.1 1.8 0.9 03/28/2006 00:50:00 2 0.3 2.6 1.5 1.9 0.4 2.6 1.1 2.2 0.4 3 1.5 145 6 142 165 1.4 0 1.6 1.4 03/28/2006 01:00:00 1.6 0.5 2.3 0.4 1.5 0.5 2.3 0.4 1.8 0.5 2.6 0.4 156 8 151 165 1.3 0 1.6 1.1 03/28/2006 01:10:00 1.2 0.3 2.3 0.4 0.9 0.5 1.9 0.4 1.5 0.4 2.3 0.7 155 5 161 165 1.3 0 1.6 1.4 03/28/2006 01:20:00 1.8 0.4 2.6 0.4 1.7 0.5 2.6 0.4 2.1 0.3 2.6 1.1 151 7 160 165 1.2 0 1.6 1.1 03/28/2006 01:30:00 2.1 0.4 3 1.5 2.1 0.4 3 1.1 2.4 0.3 3 1.9 157 8 158 165 1.2 0 1.4 1.1 03/28/2006 01:40:00 2 0.3 2.6 1.1 2.1 0.3 2.6 1.5 2.3 0.3 3 1.5 152 6 161 165 1.2 0 1.4 0.9 03/28/2006 01:50:00 1.8 0.3 2.3 1.1 1.8 0.3 2.6 1.1 2.1 0.2 2.6 1.5 153 5 154 165 1.2 0.1 1.4 0.9 03/28/2006 02:00:00 1.7 0.2 2.3 1.1 1.7 0.2 2.3 1.1 2 0.3 2.6 1.1 148 6 157 165 1.1 0.2 1.4 0.9 03/28/2006 02:10:00 2 0.2 2.3 1.5 2.1 0.2 2.3 1.5 2.4 0.2 3 1.9 140 2 140 165 1.1 0.1 1.4 0.7 03/28/2006 02:20:00 2.2 0.2 2.6 1.5 2.3 0.2 2.6 1.5 2.5 0.2 3 1.9 136 3 135 165 1.2 0 1.4 0.9 03/28/2006 02:30:00 2.3 0.3 3 1.5 2.4 0.3 3 1.9 2.6 0.3 3.4 1.9 140 7 146 165 1.2 0 1.4 0.9 03/28/2006 02:40:00 2.8 0.2 3.4 2.3 2.9 0.2 3.4 2.3 3.1 0.2 3.4 2.6 152 3 154 165 1.2 0 1.4 0.9 03/28/2006 02:50:00 2.3 0.2 3 1.9 2.5 0.2 3 1.9 2.7 0.2 3.4 2.3 152 2 151 165 1.2 0 1.4 0.9 03/28/2006 03:00:00 2.4 0.3 3 1.9 2.5 0.2 3 1.5 2.7 0.2 3 1.9 153 0 154 165 1.1 0 1.4 0.9 03/28/2006 03:10:00 2.6 0.3 3 1.9 2.6 0.3 3 1.9 2.7 0.2 3.4 2.3 153 0 154 165 1.1 0 1.4 0.7 03/28/2006 03:20:00 2 0.2 2.6 1.5 2 0.2 2.6 1.5 2.2 0.2 2.6 1.5 153 0 154 165 1.1 0 1.4 0.7 03/28/2006 03:30:00 2 0.2 2.3 1.9 2 0.2 2.3 1.9 2.2 0.1 2.3 1.9 153 0 154 165 1.1 0 1.4 0.4 03/28/2006 03:40:00 1.8 0.2 2.3 1.5 1.8 0.2 2.3 1.5 2 0.2 2.6 1.5 153 0 154 165 1.1 0 1.4 0.9 03/28/2006 03:50:00 2.1 0.2 2.6 1.5 2.2 0.2 2.6 1.9 2.3 0.2 2.6 1.9 153 0 154 165 1 0 1.4 0.9 03/28/2006 04:00:00 2.3 0.2 2.6 1.9 2.4 0.3 3 1.9 2.6 0.1 3 2.3 153 0 154 165 1.1 0 1.4 0.9 03/28/2006 04:10:00 2.4 0.2 2.6 2.3 2.7 0.2 3 2.3 2.7 0.2 3 2.6 153 0 154 165 1.1 0 1.4 0.9 03/28/2006 04:20:00 2.6 0.2 3 2.3 2.9 0.2 3.4 2.6 3 0.2 3.4 2.6 153 0 154 165 1.1 0 1.4 0.9 03/28/2006 04:30:00 2.5 0.2 3 1.9 2.9 0.2 3.4 2.6 3 0.2 3.4 2.6 153 0 154 165 0.9 0 1.4 0.9 03/28/2006 04:40:00 2.6 0.2 3 2.3 2.9 0.2 3.4 2.6 2.9 0.2 3.4 2.6 153 0 154 165 1 0 1.4 0.9 03/28/2006 04:50:00 2.9 0.2 3.4 2.3 3.2 0.2 3.8 2.6 3.2 0.2 3.8 2.6 153 0 154 165 1 0 1.4 0.7 03/28/2006 05:00:00 3.4 0.2 3.8 3 3.7 0.2 4.2 3 3.6 0.2 4.2 3 153 0 154 165 1.1 0 1.4 0.7 03/28/2006 05:10:00 3.6 0.2 3.8 3.4 3.8 0.2 4.2 3.4 3.7 0.2 4.2 3.4 153 0 154 165 1 0 1.4 0.7 03/28/2006 05:20:00 3.3 0.3 3.8 2.6 3.4 0.3 3.8 3 3.3 0.2 3.8 2.6 153 0 154 165 1 0 1.4 0.4 03/28/2006 05:30:00 3 0.3 3.8 1.9 3.2 0.3 3.8 2.3 3 0.3 3.8 2.3 153 0 154 165 1.1 0 1.4 0.4 03/28/2006 05:40:00 2.9 0.3 3.8 2.3 3 0.3 3.8 2.3 2.8 0.3 3.8 2.3 153 0 154 165 1.1 0 1.4 0.7 03/28/2006 05:50:00 3.3 0.3 3.8 2.3 3.4 0.3 3.8 2.6 3.3 0.3 3.8 2.3 153 0 154 165 1.1 0 1.4 0.7 03/28/2006 06:00:00 2.8 0.4 3.8 1.9 2.8 0.4 3.8 1.9 2.7 0.3 3.4 2.3 153 0 154 165 0.9 0.1 1.4 0.2 03/28/2006 06:10:00 2.4 0.4 3 1.5 2.4 0.4 3 1.5 2.4 0.3 3 1.9 153 0 154 165 0.8 0 0.9 0.7 03/28/2006 06:20:00 2.8 0.3 3.8 1.9 2.8 0.3 3.8 1.9 2.7 0.3 3.4 1.9 153 0 154 165 0.8 0 0.9 0.7 03/28/2006 06:30:00 2.5 0.4 3.4 1.5 2.5 0.4 3.4 1.5 2.4 0.3 3 1.9 153 0 154 165 0.7 0 0.9 0.7 03/28/2006 06:40:00 2 0.3 2.6 1.1 2 0.3 3 1.1 1.9 0.2 2.6 1.5 153 0 154 165 0.7 0 0.9 0.7 03/28/2006 06:50:00 2.4 0.3 3 1.5 2.4 0.3 3.4 1.5 2.5 0.2 3.4 1.9 153 0 154 165 0.7 0 0.9 0.7 03/28/2006 07:00:00 2.3 0.3 3 1.5 2.3 0.3 3 1.5 2.5 0.2 3 1.9 153 0 154 165 0.7 0 0.9 0.7 03/28/2006 07:10:00 2.1 0.3 3 1.5 2.1 0.3 3 1.5 2.3 0.2 3 1.9 153 0 154 165 0.8 0 0.9 0.7 03/28/2006 07:20:00 2.3 0.4 3.4 1.5 2.4 0.4 3.4 1.5 2.5 0.3 3.4 1.9 153 0 154 165 1.1 0.2 1.6 0.7 03/28/2006 07:30:00 2.8 0.5 4.2 1.5 2.8 0.4 3.8 1.9 2.9 0.4 3.8 2.3 153 0 154 165 1.7 0.1 1.8 1.4 03/28/2006 07:40:00 3.7 0.5 4.9 2.6 3.7 0.5 4.6 2.6 3.8 0.5 4.9 2.6 153 0 154 165 2 0 2.3 1.6 03/28/2006 07:50:00 3.1 0.4 4.2 1.9 3 0.4 4.2 1.9 3.2 0.4 4.2 2.6 154 0 154 165 2.3 0 2.6 1.8 03/28/2006 08:00:00 2.8 0.4 3.4 1.9 2.7 0.3 3.4 1.9 3 0.3 3.4 2.3 154 0 154 165 2.4 0.1 2.8 1.8 03/28/2006 08:10:00 2.9 0.5 3.8 1.9 2.8 0.4 3.8 1.9 3.2 0.4 3.8 2.3 163 2 164 165 2.7 0 2.8 2.6 03/28/2006 08:20:00 3.3 0.4 4.6 1.9 3.1 0.4 4.2 2.3 3.4 0.3 4.2 2.3 164 1 165 165 2.7 0.1 3 2.3 03/28/2006 08:30:00 3.1 0.3 3.8 2.3 2.8 0.3 3.8 1.9 3.1 0.3 3.8 2.6 165 11 165 165 2.9 0.1 3.3 2.3 03/28/2006 08:40:00 3.1 0.3 3.8 2.3 2.8 0.4 3.8 1.9 3.2 0.3 3.8 2.3 167 5 165 165 3.1 0 3.3 2.6 03/28/2006 08:50:00 3.2 0.3 4.2 2.3 2.8 0.3 4.2 1.9 3.2 0.3 4.2 2.6 166 6 164 165 2.7 0.1 3.3 2.3 03/28/2006 09:00:00 3 0.3 3.8 2.3 2.5 0.3 3.8 1.9 3 0.2 3.4 2.3 169 5 173 165 2.3 0.1 2.6 1.8 03/28/2006 09:10:00 2.7 0.3 3.4 1.9 2.3 0.3 3 1.5 2.7 0.3 3.4 1.9 174 5 179 165 2.3 0 2.6 1.6 03/28/2006 09:20:00 2.4 0.3 3.4 1.5 2.2 0.3 3 1.5 2.4 0.3 3.4 1.5 166 4 166 165 2.5 0.1 2.8 1.8 03/28/2006 09:30:00 2.1 0.4 3.4 1.1 2.1 0.4 3 1.1 2.3 0.3 3 1.5 160 5 165 165 2.6 0 2.8 2.1 03/28/2006 09:40:00 2.5 0.4 3.4 1.5 2.5 0.4 3.4 1.5 2.7 0.3 3.4 1.9 153 13 152 165 2.8 0 3 2.6 03/28/2006 09:50:00 3.2 0.4 4.2 2.3 3.2 0.4 4.6 2.3 3.4 0.4 4.6 2.3 145 7 147 165 3 0 3.3 2.8 03/28/2006 10:00:00 3.3 0.5 4.6 1.9 3.3 0.5 4.6 1.9 3.4 0.5 4.9 1.9 147 8 149 165 3 0.1 3.5 2.6 03/28/2006 10:10:00 3.6 0.4 4.9 2.3 3.6 0.5 4.9 2.6 3.8 0.5 5.3 2.3 144 11 145 165 3 0 3.3 2.8 03/28/2006 10:20:00 4.3 0.5 5.7 3 4.2 0.6 5.7 3 4.4 0.6 6.1 3 148 9 156 165 3 0.1 3.3 2.6 03/28/2006 10:30:00 4.2 0.4 5.3 3 4.1 0.5 5.7 2.6 4.3 0.4 6.1 3 150 9 143 165 3 0.1 3.3 2.6 03/28/2006 10:40:00 4.4 0.6 6.1 3 4.3 0.6 6.1 3 4.5 0.6 6.1 3 148 9 151 165 3.1 0.1 3.5 2.8 03/28/2006 10:50:00 4.5 0.6 6.1 3 4.5 0.6 6.1 3 4.4 0.7 6.1 3 139 9 145 165 3 0.1 3.5 2.6 03/28/2006 11:00:00 4.4 0.6 6.1 2.6 4.4 0.6 6.5 3 4.4 0.6 6.1 2.3 138 10 126 165 3 0.1 3.5 2.8 03/28/2006 11:10:00 4.8 0.5 6.1 3 4.7 0.5 6.1 3 4.8 0.6 6.5 3.4 146 14 148 165 3.2 0.2 3.8 2.8 03/28/2006 11:20:00 4.7 0.6 6.8 3.4 4.8 0.7 6.8 3.4 4.8 0.7 7.2 3.4 147 9 144 165 3.6 0 3.8 3.3 03/28/2006 11:30:00 4.5 0.6 6.1 2.6 4.5 0.6 6.1 2.6 4.6 0.7 6.5 2.6 157 9 153 165 3.8 0 4.3 3.5 03/28/2006 11:40:00 4.5 0.5 5.7 3.4 4.4 0.5 6.1 3.4 4.6 0.5 6.1 3.4 159 13 162 165 3.6 0.2 4.3 3.3 03/28/2006 11:50:00 3.9 0.7 6.5 2.3 3.9 0.7 6.1 2.3 4 0.6 5.3 2.3 157 9 142 165 3.7 0.3 4.5 3.3 03/28/2006 12:00:00 3.7 0.6 5.7 2.3 3.7 0.5 5.3 1.9 3.6 0.5 5.3 2.6 154 12 157 165 4 0.1 4.5 3.5 03/28/2006 12:10:00 3.2 0.5 4.6 1.5 3.2 0.5 4.6 1.9 3.2 0.6 4.6 1.5 149 10 145 165 4.2 0 4.8 3.8 03/28/2006 12:20:00 3.2 0.7 5.7 1.9 3.2 0.7 5.3 1.5 3.2 0.7 5.3 1.9 159 13 164 165 4.5 0 4.8 4.3 03/28/2006 12:30:00 3.6 0.8 5.7 1.5 3.5 0.8 5.3 1.5 3.6 0.7 4.9 1.9 156 13 148 165 4.3 0.1 4.8 4.3 03/28/2006 12:40:00 3.6 0.8 5.7 1.5 3.6 0.8 5.7 1.9 3.5 0.8 5.7 1.9 143 18 157 165 4.4 0.1 4.8 4.3 03/28/2006 12:50:00 3.2 0.7 5.3 1.5 3.2 0.7 5.3 1.9 3.2 0.8 5.3 1.5 144 15 153 165 4.6 0 5 4.3 03/28/2006 13:00:00 3.2 0.8 4.9 0.7 3.2 0.8 5.3 0.7 3.2 0.8 5.3 0.7 149 13 139 165 4.7 0.1 5 4.5 03/28/2006 13:10:00 3.9 0.7 5.7 2.3 3.8 0.7 5.7 2.3 3.8 0.6 5.7 2.3 157 13 172 165 4.6 0 5 4.3 03/28/2006 13:20:00 3.1 0.5 4.2 1.9 3.1 0.5 4.6 1.9 3.2 0.5 4.6 1.9 149 16 132 165 4.6 0.1 5 4.3 03/28/2006 13:30:00 3.3 0.8 5.3 1.5 3.3 0.8 5.3 1.1 3.3 0.8 4.9 1.1 142 17 156 165 4.8 0 5.2 4.8 03/28/2006 13:40:00 3.1 0.9 5.7 0.7 3.1 0.9 5.7 0.7 3.1 0.9 5.3 1.1 145 20 157 165 5.1 0.1 5.5 4.8 03/28/2006 13:50:00 3.1 0.8 4.9 1.1 3.1 0.8 4.9 1.1 3.1 0.7 5.3 1.5 139 17 155 165 5.1 0 5.5 5 03/28/2006 14:00:00 3 0.6 4.6 1.5 3 0.6 4.6 0.7 2.9 0.7 4.2 0.4 146 22 133 165 5.2 0.1 5.7 4.8 03/28/2006 14:10:00 3.5 0.7 6.1 1.9 3.5 0.7 6.1 1.9 3.4 0.8 5.3 0.7 138 16 144 165 5.6 0.3 6 5 03/28/2006 14:20:00 3.2 0.8 4.9 1.1 3.2 0.8 4.9 1.1 3.2 0.7 4.9 1.1 159 15 147 165 5.7 0 6 5.5 03/28/2006 14:30:00 3.2 0.7 4.9 1.9 3.2 0.7 5.3 1.9 3.2 0.7 4.9 1.5 152 20 151 165 5.6 0 6 5.5 03/28/2006 14:40:00 3.3 0.7 5.3 1.5 3.3 0.7 5.3 1.1 3.2 0.7 5.3 1.5 135 17 130 165 5.7 0.3 6.2 5.2 03/28/2006 14:50:00 2.1 0.8 4.6 0.4 2.1 0.9 4.6 0.4 1.9 0.9 4.9 0.4 107 38 124 165 6.6 0.2 7 6 03/28/2006 15:00:00 2.1 0.6 3.8 0.4 2.1 0.6 3.4 0.4 1.9 0.6 3 0.4 95 36 119 165 6.5 0.1 7 6 03/28/2006 15:10:00 3 0.6 4.6 1.5 3.1 0.6 4.6 1.5 2.9 0.7 4.2 1.1 111 15 115 165 6.6 0.4 7.3 5.7 03/28/2006 15:20:00 2.4 1 5.3 0.4 2.5 1 5.3 0.4 2.2 0.9 5.3 0.4 101 32 67 165 6.4 0.2 7 5.7 03/28/2006 15:30:00 2.7 0.8 4.6 0.7 2.7 0.8 4.6 0.7 2.6 0.7 4.2 0.7 101 24 116 165 6.2 0.2 6.7 5.7 03/28/2006 15:40:00 2.7 0.7 4.6 0.7 2.7 0.8 4.6 0.4 2.6 0.7 4.6 0.4 86 33 108 165 5.8 0.2 6.2 5.2 03/28/2006 15:50:00 3 0.5 4.2 1.9 3 0.5 4.2 1.5 2.9 0.5 3.8 1.5 54 10 57 165 5.1 0.3 5.7 4.3 03/28/2006 16:00:00 2.9 0.5 4.2 1.5 2.9 0.5 4.2 1.5 2.9 0.6 4.2 1.5 46 8 53 165 3.6 0.4 4.5 2.8 03/28/2006 16:10:00 2.9 0.6 4.6 1.5 2.9 0.6 4.9 1.5 2.8 0.5 4.2 1.5 42 13 44 165 3.2 0.1 3.5 2.6 03/28/2006 16:20:00 3.3 0.4 4.2 2.3 3.3 0.4 4.2 2.3 3.3 0.4 4.2 2.3 40 7 39 165 3 0 3.3 2.8 03/28/2006 16:30:00 3.1 0.5 4.6 1.9 3 0.5 4.6 1.9 3 0.5 4.2 1.9 34 13 23 165 3.6 0.2 3.8 3 03/28/2006 16:40:00 3.4 0.4 4.2 2.3 3.4 0.4 4.2 1.9 3.4 0.5 4.6 2.3 26 8 37 165 3.3 0.2 4.3 3 03/28/2006 16:50:00 2.9 0.5 4.2 1.5 2.8 0.5 4.2 1.5 2.9 0.5 4.2 1.9 26 15 29 165 4.6 0.1 5 4 03/28/2006 17:00:00 3.1 0.5 4.2 1.5 3 0.5 4.2 1.9 3.1 0.6 4.2 1.5 40 9 34 165 4.4 0.1 5 4.3 03/28/2006 17:10:00 2.6 0.5 3.8 0.7 2.6 0.5 3.8 1.1 2.6 0.5 3.4 1.1 37 11 48 165 4.3 0.1 5 4.3 03/28/2006 17:20:00 2.3 0.6 3.4 0.7 2.1 0.6 3.4 0.4 2.2 0.6 3.4 0.7 23 9 39 165 4.9 0.2 5.5 4.5 03/28/2006 17:30:00 2 0.5 3.8 1.1 1.9 0.5 3.4 0.7 1.8 0.5 3 0.7 27 11 25 165 4.9 0.1 5.5 4.5 03/28/2006 17:40:00 1.9 0.6 3 0.4 1.8 0.6 3 0.4 1.7 0.6 3.4 0.4 30 16 37 165 4.8 0.2 5.2 4.3 03/28/2006 17:50:00 1.9 0.5 3 0.4 1.8 0.5 3 0.4 1.6 0.6 3 0.4 29 17 13 165 4.8 0.1 5.2 4.5 03/28/2006 18:00:00 1.7 0.6 3 0.4 1.7 0.6 3 0.4 1.6 0.5 3 0.4 44 11 54 165 4.5 0.2 5.5 4.3 03/28/2006 18:10:00 2.3 0.4 3.4 1.5 2.3 0.4 3.4 1.5 2.3 0.4 3.4 1.5 54 16 39 165 4 0.2 4.5 3.5 03/28/2006 18:20:00 2.6 0.5 3.8 1.5 2.6 0.5 4.2 1.5 2.6 0.5 4.2 1.5 43 11 25 165 3.6 0.1 4.3 3.5 03/28/2006 18:30:00 2.5 0.5 3.8 1.1 2.5 0.5 3.8 1.1 2.5 0.5 3.8 1.1 44 13 54 165 3.5 0 3.8 3.5 03/28/2006 18:40:00 2.4 0.4 3 1.1 2.4 0.4 3 1.1 2.4 0.4 3.4 1.5 39 7 29 165 3.2 0.1 3.5 2.8 03/28/2006 18:50:00 1.9 0.3 2.6 1.1 1.7 0.3 2.6 0.7 1.8 0.3 2.6 1.1 21 13 22 165 2.9 0 3 2.8 03/28/2006 19:00:00 1.8 0.4 2.6 0.7 1.7 0.4 2.3 0.7 1.8 0.4 2.6 0.7 22 8 22 165 3 0.1 3.3 2.8 03/28/2006 19:10:00 1.4 0.4 2.6 0.4 1.1 0.4 2.3 0.4 1.4 0.5 2.6 0.7 11 9 15 165 2.9 0 3 2.8 03/28/2006 19:20:00 1.5 0.3 1.9 0.7 1.3 0.4 1.9 0.4 1.4 0.4 2.3 0.7 25 8 23 165 2.5 0.1 2.8 2.3 03/28/2006 19:30:00 1.9 0.2 2.3 1.1 1.7 0.2 2.3 1.1 2 0.3 2.6 1.5 25 2 26 165 2.1 0.1 2.3 1.8 03/28/2006 19:40:00 2.3 0.3 3 1.5 1.8 0.4 2.6 0.7 2.4 0.3 3 1.9 12 5 7 165 1.9 0 2.1 1.8 03/28/2006 19:50:00 1.8 0.3 2.3 1.1 1.1 0.4 2.3 0.4 1.8 0.3 2.6 1.1 4 5 9 165 1.8 0 1.8 1.6 03/28/2006 20:00:00 1.9 0.3 2.6 1.1 1.4 0.5 2.3 0.4 2 0.3 2.6 1.5 13 2 15 165 1.8 0 1.8 1.6 03/28/2006 20:10:00 1.6 0.2 2.3 1.1 1.4 0.4 2.3 0.4 1.8 0.2 2.3 1.5 349 5 347 165 1.9 0 1.8 1.8 03/28/2006 20:20:00 1.4 0.2 1.9 1.1 1.1 0.3 1.9 0.4 1.6 0.2 2.3 1.1 351 0 351 165 1.9 0 2.1 1.8 03/28/2006 20:30:00 1.3 0.2 1.9 0.7 1 0.4 1.9 0.4 1.5 0.2 1.9 1.1 351 0 351 165 2 0 2.3 1.8 03/28/2006 20:40:00 1.4 0.3 2.3 0.7 1.2 0.3 1.9 0.4 1.5 0.2 1.9 0.7 346 9 0 165 2 0 2.3 1.8 03/28/2006 20:50:00 1.2 0.4 2.3 0.4 1.4 0.4 2.3 0.4 1.2 0.4 2.3 0.4 332 13 315 165 2 0 2.3 1.8 03/28/2006 21:00:00 1.3 0.4 2.3 0.4 1.5 0.4 3 0.7 1.4 0.4 2.3 0.4 308 15 328 165 2 0 2.3 1.8 03/28/2006 21:10:00 1.5 0.4 2.6 0.4 1.7 0.4 2.6 0.7 1.5 0.5 2.6 0.4 322 18 327 165 2.1 0 2.3 1.8 03/28/2006 21:20:00 2.8 0.4 3.8 1.9 2.9 0.3 3.8 1.9 2.8 0.3 3.8 1.9 332 6 338 165 2 0 2.3 1.8 03/28/2006 21:30:00 3.3 0.4 4.2 2.3 3.3 0.4 4.2 2.3 3.2 0.4 4.2 2.3 322 7 320 165 1.8 0 2.1 1.6 03/28/2006 21:40:00 3.5 0.4 4.2 2.6 3.6 0.3 4.6 3 3.7 0.3 4.6 3 332 6 333 165 1.7 0 1.8 1.6 03/28/2006 21:50:00 3.3 0.2 3.8 2.6 3.4 0.3 4.2 2.3 3.4 0.2 3.8 3 341 4 339 165 1.6 0 1.8 1.4 03/28/2006 22:00:00 3.4 0.4 4.2 2.6 2.8 0.6 4.2 1.5 3.5 0.3 4.2 2.6 350 4 345 165 1.5 0 1.6 1.4 03/28/2006 22:10:00 3.2 0.4 4.2 1.9 3.1 0.6 4.2 1.5 3.3 0.4 4.2 2.3 344 5 349 165 1.7 0 1.8 1.6 03/28/2006 22:20:00 3.2 0.4 4.2 2.6 2.8 0.7 4.2 1.1 3.3 0.3 4.2 2.6 347 7 351 165 1.8 0 1.8 1.6 03/28/2006 22:30:00 3.6 0.4 4.6 2.6 2.3 0.5 3.8 1.1 3.7 0.4 4.6 3 356 6 359 165 1.8 0 1.8 1.6 03/28/2006 22:40:00 3.4 0.4 4.2 2.6 3.4 0.5 4.6 1.9 3.5 0.4 4.2 2.6 343 4 344 165 1.7 0 1.8 1.6 03/28/2006 22:50:00 3.3 0.4 4.6 2.3 3.2 0.6 4.9 1.5 3.4 0.4 4.2 2.6 345 5 340 165 1.7 0 1.8 1.6 03/28/2006 23:00:00 3.6 0.4 4.6 2.6 3.4 0.5 4.6 2.3 3.6 0.3 4.6 3 345 4 349 165 1.7 0 1.8 1.4 03/28/2006 23:10:00 3.8 0.4 4.6 2.6 3.3 0.6 4.6 1.5 3.8 0.3 4.6 3 347 6 353 165 1.4 0.1 1.6 0.9 03/28/2006 23:20:00 4.2 0.5 5.3 3 4.2 0.5 5.7 3 4.2 0.4 5.3 3 340 5 350 165 1.4 0 1.6 1.4 03/28/2006 23:30:00 4.6 0.5 6.1 3.4 4.1 0.8 6.1 1.9 4.6 0.6 6.1 3.4 346 6 356 165 1.4 0.1 1.6 1.4 03/28/2006 23:40:00 4.8 0.4 5.7 3.8 3.8 0.8 5.7 2.3 5 0.4 5.7 4.2 349 5 352 165 1.4 0 1.8 1.4 03/28/2006 23:50:00 4.2 0.5 5.3 3.4 4.4 0.5 5.7 3 4.4 0.5 5.7 3.4 340 4 347 165 1.1 0.1 1.4 0.9 03/29/2006 00:00:00 4.5 0.5 5.7 3.4 4.2 0.7 5.7 2.3 4.6 0.5 5.7 3.8 347 3 350 165 1 0.2 1.4 0.7 03/29/2006 00:10:00 4 0.4 4.9 3 3.5 0.7 4.9 1.9 4.2 0.4 5.3 3 348 5 351 165 1.2 0.1 1.6 0.9 03/29/2006 00:20:00 3.7 0.3 4.9 3 3.8 0.4 4.9 2.3 3.9 0.3 4.9 3.4 341 5 347 165 1.4 0 1.6 1.1 03/29/2006 00:30:00 3.6 0.4 4.6 2.6 3.6 0.3 4.2 2.6 3.7 0.3 4.6 2.6 341 5 347 165 1.4 0.1 1.6 0.9 03/29/2006 00:40:00 2.6 0.4 3.4 1.5 2.8 0.4 3.4 1.9 2.7 0.3 3.4 1.9 327 7 319 165 1.4 0 1.6 1.4 03/29/2006 00:50:00 3.3 0.5 4.2 1.9 3.3 0.6 4.6 1.9 3.6 0.5 4.6 2.3 343 5 338 165 1.5 0 1.6 1.4 03/29/2006 01:00:00 2.8 0.5 3.8 1.1 3 0.5 4.2 1.1 3.1 0.4 3.8 1.5 334 8 343 165 1.8 0.2 2.3 1.4 03/29/2006 01:10:00 1.7 0.6 3 0.4 1.8 0.6 3 0.4 1.9 0.5 3.4 0.4 321 26 332 165 2 0.1 2.3 1.6 03/29/2006 01:20:00 1.1 0.4 2.6 0.4 1.3 0.4 3 0.7 1.4 0.5 3.4 0.7 297 6 280 165 1.6 0 1.8 1.4 03/29/2006 01:30:00 0.7 0.4 2.3 0.4 0.8 0.5 1.9 0.4 0.7 0.4 1.5 0.4 296 18 291 165 1.9 0.2 2.3 1.4 03/29/2006 01:40:00 1.2 0.5 2.3 0.4 1.3 0.5 2.6 0.4 1.5 0.6 2.6 0.4 322 29 280 165 1.9 0.2 2.6 1.4 03/29/2006 01:50:00 1.4 0.6 2.6 0.4 1.7 0.5 2.6 0.4 1.6 0.5 2.6 0.4 298 20 329 165 1.7 0.2 2.1 0.9 03/29/2006 02:00:00 1.7 0.4 3.4 0.7 1.9 0.4 3.4 1.1 1.7 0.4 3.4 0.7 312 17 321 165 1.7 0 1.8 1.4 03/29/2006 02:10:00 1.5 0.4 2.3 0.4 1.7 0.4 2.6 0.7 1.6 0.4 3 0.7 303 16 288 165 1.8 0 1.8 1.4 03/29/2006 02:20:00 1.9 0.7 3.8 0.7 2.2 0.6 3.8 1.1 2.2 0.7 4.2 0.7 298 13 293 165 1.7 0 1.8 1.1 03/29/2006 02:30:00 1.9 0.6 3.4 0.4 2.1 0.6 3.8 0.7 2.3 0.8 4.2 0.7 314 20 303 165 1.4 0 1.6 1.1 03/29/2006 02:40:00 3.3 1.2 5.7 0.4 3.5 1.2 6.1 0.4 3.2 0.9 5.7 1.5 297 9 298 165 1.4 0 1.8 1.1 03/29/2006 02:50:00 4.8 0.6 7.6 3.4 4.9 0.6 8 3.8 4.3 0.6 6.1 2.3 306 7 304 165 1.5 0.1 1.8 0.9 03/29/2006 03:00:00 6.3 0.8 8.8 4.6 6.3 0.8 8.8 4.6 5.2 0.8 7.6 3 306 7 302 165 1.4 0 1.6 0.9 03/29/2006 03:10:00 7 0.9 9.9 4.9 7 0.8 9.9 4.6 5.5 0.8 8 3.4 303 6 294 165 1.7 0 1.8 1.4 03/29/2006 03:20:00 7.4 0.6 8.8 4.9 7.3 0.7 9.1 4.9 5.7 0.7 7.6 4.2 303 5 305 165 1.7 0 1.8 1.4 03/29/2006 03:30:00 6.9 0.6 8.4 5.3 6.9 0.6 8.4 5.3 5.3 0.8 7.2 3.8 304 5 296 165 1.7 0 1.8 1.1 03/29/2006 03:40:00 5.7 1 8 2.6 5.6 1 8 2.6 4.8 1 7.6 1.9 300 11 303 165 1.8 0.1 1.8 1.4 03/29/2006 03:50:00 5.2 0.6 6.8 3.4 5.2 0.6 6.5 3.4 4.5 0.6 5.7 3 307 10 300 165 1.7 0.1 1.8 1.4 03/29/2006 04:00:00 4.9 0.7 6.5 2.6 4.9 0.7 6.5 3 3.9 0.5 5.7 2.6 302 9 296 165 1.6 0 1.8 1.1 03/29/2006 04:10:00 5.2 0.6 7.2 3.8 5.3 0.6 6.8 3.4 4.1 0.5 5.3 2.6 301 6 302 165 1.5 0.1 1.6 1.1 03/29/2006 04:20:00 5.5 0.6 6.8 3.8 5.6 0.6 6.8 4.2 4.3 0.5 5.7 3 298 5 301 165 1.5 0.1 1.8 1.4 03/29/2006 04:30:00 5.8 0.5 6.8 4.6 5.9 0.5 7.2 4.6 4.5 0.5 6.1 3.4 302 5 298 165 1.4 0.1 1.6 0.9 03/29/2006 04:40:00 5.8 0.7 7.2 3.8 5.8 0.7 7.2 4.2 4.3 0.6 6.1 3 298 6 307 165 1.4 0 1.6 1.1 03/29/2006 04:50:00 5.1 0.8 6.8 3.4 5.1 0.8 6.8 3 4.3 0.7 6.1 2.6 306 8 295 165 1.4 0 1.6 1.1 03/29/2006 05:00:00 4.6 0.5 5.7 3.4 4.6 0.4 5.7 3.4 4.1 0.5 5.3 2.6 309 5 308 165 1.2 0 1.6 0.9 03/29/2006 05:10:00 4.1 0.5 5.3 2.6 4.2 0.5 5.3 2.6 3.5 0.5 5.3 2.3 308 7 304 165 1 0.1 1.4 0.7 03/29/2006 05:20:00 4.6 0.5 6.1 3.4 4.7 0.5 6.5 3.8 3.8 0.5 5.7 2.6 305 5 300 165 0.8 0 0.9 0.7 03/29/2006 05:30:00 5.5 0.8 7.2 3 5.4 0.8 7.2 3 4.7 0.8 6.5 2.6 308 8 309 165 1.1 0.1 1.4 0.7 03/29/2006 05:40:00 3.4 0.7 4.9 1.5 3.5 0.6 4.9 1.5 3.6 0.6 4.9 2.3 318 8 310 165 1.2 0 1.4 0.9 03/29/2006 05:50:00 2.9 0.6 4.6 1.1 3 0.5 4.6 1.9 3.1 0.4 4.2 1.9 321 13 298 165 1.3 0.1 1.6 0.9 03/29/2006 06:00:00 3.4 0.7 6.1 1.9 3.6 0.7 5.7 1.5 3.4 0.6 6.1 1.9 313 15 291 165 1.3 0.1 1.6 0.9 03/29/2006 06:10:00 4.5 0.8 6.8 2.3 4.6 0.8 6.8 2.6 4.1 0.7 6.1 2.3 308 9 296 165 1.5 0.2 1.8 0.9 03/29/2006 06:20:00 5.4 0.8 7.2 3.8 5.5 0.8 7.6 3.8 4.6 0.6 6.1 3.4 303 7 292 165 1.4 0.1 1.6 0.9 03/29/2006 06:30:00 6.5 0.6 7.6 4.6 6.5 0.6 7.6 4.9 4.9 0.5 6.5 3.8 304 4 299 165 1.3 0 1.6 0.7 03/29/2006 06:40:00 5.9 0.5 6.8 4.9 6 0.5 6.8 4.6 4.4 0.5 5.7 3 302 5 302 165 1.4 0 1.6 1.4 03/29/2006 06:50:00 6.1 0.4 7.2 4.9 6.2 0.3 7.2 5.3 4.6 0.6 6.5 3.4 296 3 295 165 1.6 0 1.8 1.4 03/29/2006 07:00:00 5.3 0.6 6.5 3.8 5.4 0.6 6.8 3.8 4.1 0.4 5.3 3 302 5 301 165 1.8 0.1 2.1 1.6 03/29/2006 07:10:00 3.5 0.7 5.3 1.9 3.6 0.7 5.3 1.9 3.5 0.6 5.3 2.3 319 12 313 165 2.1 0 2.3 1.8 03/29/2006 07:20:00 4.2 1 6.5 1.9 4.3 1 6.5 2.3 3.8 0.8 6.1 1.9 313 9 306 165 2.6 0 2.8 2.3 03/29/2006 07:30:00 5.3 1 7.2 3 5.3 1 7.2 2.6 4.6 0.9 6.5 2.6 310 9 305 165 2.5 0.1 2.8 1.8 03/29/2006 07:40:00 5.1 1.1 7.6 2.3 5.1 1 7.2 2.3 4.3 1 6.8 1.9 307 9 318 165 2.5 0.1 2.8 2.3 03/29/2006 07:50:00 6.1 0.8 7.6 4.2 6 0.8 7.6 4.2 5.3 0.8 7.2 3.4 310 6 307 165 2.4 0.2 2.8 1.8 03/29/2006 08:00:00 6.2 0.7 8 4.2 6 0.7 7.6 4.2 5.1 0.8 7.6 3.4 308 6 306 165 2.8 0.2 3.3 2.3 03/29/2006 08:10:00 6.2 0.6 7.6 4.6 6.1 0.6 7.2 4.6 5.2 0.7 6.8 3.4 307 6 305 165 3 0.2 3.5 2.6 03/29/2006 08:20:00 6.5 0.8 8.8 4.6 6.4 0.8 8.8 4.6 5.2 0.8 7.2 3.4 303 8 301 165 2.6 0.1 2.8 2.3 03/29/2006 08:30:00 6.4 0.6 8 4.6 6.4 0.6 8 4.6 5.2 0.8 7.2 3.4 294 5 295 165 2.4 0.2 2.8 1.8 03/29/2006 08:40:00 6.2 0.7 8 4.2 6.2 0.7 7.6 4.2 4.6 0.7 6.5 3 299 5 302 165 2.6 0.1 2.8 2.3 03/29/2006 08:50:00 5.1 0.6 6.5 3.8 5.1 0.6 6.5 3.4 4.2 0.6 5.7 2.6 302 7 304 165 3 0.1 3.5 2.8 03/29/2006 09:00:00 4.3 1 6.5 2.6 4.2 1.1 6.5 1.5 3.7 0.5 5.7 2.6 319 18 297 165 3.7 0.2 4.5 3 03/29/2006 09:10:00 2.6 0.8 4.6 0.7 2.6 0.8 4.6 0.4 2.5 0.8 4.2 0.7 327 15 317 165 4.9 0.2 5.2 4.3 03/29/2006 09:20:00 2.5 1.2 5.7 0.7 2.5 1.2 5.7 0.7 2.1 1 5.3 0.4 309 18 284 165 5 0.2 5.5 4.5 03/29/2006 09:30:00 5.6 0.8 7.6 3.8 5.6 0.8 7.6 3.8 4.4 0.7 7.2 2.6 297 7 293 165 3.6 0.4 4.8 3 03/29/2006 09:40:00 5.6 0.6 6.8 3.8 5.6 0.7 7.2 3.8 4.5 0.6 6.8 2.6 298 6 298 165 3.3 0.1 3.8 3 03/29/2006 09:50:00 4.9 0.5 6.1 3.4 4.9 0.5 6.1 3.4 4 0.5 4.9 3 302 5 298 165 3.6 0.1 4.3 3.3 03/29/2006 10:00:00 5.3 0.5 6.5 3.4 5.4 0.6 6.5 3.4 4.4 0.6 5.7 2.6 295 5 295 165 3.6 0.2 4.3 3.3 03/29/2006 10:10:00 5.6 0.5 6.5 3.4 5.6 0.5 6.5 3.8 4.9 0.6 6.5 3.4 302 8 307 165 3.6 0.1 4.3 3.5 03/29/2006 10:20:00 5.2 0.5 6.8 3.8 5.2 0.5 6.5 3.8 5 0.6 6.5 3 311 9 300 165 4.3 0.1 4.8 3.8 03/29/2006 10:30:00 4.7 0.8 6.5 3 4.9 0.9 6.5 2.6 4.4 1 6.5 2.3 283 12 280 165 4.1 0 4.8 3.8 03/29/2006 10:40:00 5.2 0.5 6.5 4.2 5.3 0.5 6.5 4.2 4.9 0.7 6.5 3 285 7 277 165 4 0 4.5 3.8 03/29/2006 10:50:00 4.1 0.5 5.7 2.6 4 0.5 5.7 2.6 3.9 0.5 4.9 2.6 321 11 304 165 5 0.7 6 3.8 03/29/2006 11:00:00 3.9 0.4 4.9 2.6 3.8 0.4 4.9 2.6 3.7 0.5 4.9 2.3 322 9 319 165 5.9 0.1 6.2 5.7 03/29/2006 11:10:00 3.9 0.6 6.1 2.3 3.8 0.6 6.1 1.5 3.8 0.6 6.1 1.5 336 12 302 165 6.6 0.3 7.3 5.7 03/29/2006 11:20:00 3.2 0.4 4.2 1.9 3.1 0.4 4.2 1.5 3.1 0.4 4.2 2.3 329 9 323 165 7.1 0.1 7.5 6.7 03/29/2006 11:30:00 3.2 0.6 4.9 1.9 3.1 0.6 4.9 1.9 3 0.8 5.3 1.1 320 9 320 165 6.7 0.5 7.8 6 03/29/2006 11:40:00 3.9 0.5 4.9 3 3.9 0.5 5.3 2.6 3.7 0.5 4.9 2.6 316 9 326 165 6.1 0.3 6.7 5.7 03/29/2006 11:50:00 3.5 0.5 4.9 2.3 3.5 0.5 4.9 2.3 3.4 0.5 4.9 1.9 317 9 297 165 6.2 0 6.7 6 03/29/2006 12:00:00 3.7 0.6 5.3 2.6 3.7 0.6 4.9 2.3 3.4 0.6 4.9 2.3 313 6 319 165 5.9 0.2 6.7 5.7 03/29/2006 12:10:00 3.7 0.6 4.9 2.6 3.6 0.6 4.9 2.3 3.3 0.6 4.9 1.9 310 9 316 165 5.9 0.2 6.5 5.5 03/29/2006 12:20:00 3.4 0.6 4.6 2.3 3.4 0.6 4.6 1.9 3 0.6 4.6 1.5 308 9 307 165 6.1 0.3 7 5.7 03/29/2006 12:30:00 3.4 0.6 4.6 1.5 3.3 0.6 4.6 1.5 3.1 0.6 4.2 1.1 311 10 305 165 6.4 0.3 7 5.7 03/29/2006 12:40:00 2.8 0.5 4.2 1.5 2.7 0.5 4.2 1.5 2.4 0.5 3.8 1.1 317 12 317 165 7.4 0.3 8 6.5 03/29/2006 12:50:00 2.7 0.4 4.2 1.9 2.7 0.5 4.2 1.9 2.4 0.5 4.2 1.1 307 9 304 165 7 0.1 7.5 6.7 03/29/2006 13:00:00 2.7 0.5 3.8 1.5 2.7 0.5 4.2 1.5 2.4 0.5 3.8 1.5 296 9 297 165 6.7 0.2 7.3 6.2 03/29/2006 13:10:00 2.9 0.5 4.6 1.5 2.9 0.5 4.6 1.1 2.4 0.5 4.2 0.7 303 10 293 165 6.6 0.3 7.3 6.2 03/29/2006 13:20:00 3.1 0.4 4.2 1.9 3.1 0.4 4.2 1.9 2.6 0.4 3.8 1.1 302 7 300 165 6.8 0.2 7.3 6.5 03/29/2006 13:30:00 3.2 0.6 4.2 1.1 3.2 0.6 4.2 1.1 2.6 0.5 4.2 1.5 299 10 305 165 6.2 0.2 6.7 5.5 03/29/2006 13:40:00 2.2 0.6 3.4 0.4 2.2 0.6 3.8 0.4 1.8 0.6 4.2 0.4 302 15 276 165 6.6 0.4 7.3 5.5 03/29/2006 13:50:00 1.2 0.7 3 0.4 1.1 0.7 3.4 0.4 0.9 0.6 2.6 0.4 263 61 298 165 7.1 0.3 7.8 6.5 03/29/2006 14:00:00 1.4 0.9 3.8 0.4 1.3 0.9 3.8 0.4 0.8 0.6 3 0.4 268 38 287 165 7.3 0.3 7.8 6.7 03/29/2006 14:10:00 1.9 1.1 4.6 0.4 1.9 1.1 4.2 0.4 1.4 0.9 4.2 0.4 309 56 312 165 8.1 0.1 8.5 7.5 03/29/2006 14:20:00 2.6 0.8 4.2 0.4 2.6 0.9 4.2 0.4 2.2 0.8 3.8 0.7 312 19 317 165 8.5 0.2 9 7.8 03/29/2006 14:30:00 2.6 0.8 4.6 0.4 2.6 0.7 4.6 1.1 1.9 0.8 3.8 0.4 295 15 297 165 8.1 0.3 9 7.5 03/29/2006 14:40:00 2.4 0.8 4.9 0.7 2.4 0.9 4.9 0.4 1.8 0.8 4.2 0.4 309 27 294 165 8.1 0.2 8.5 7.5 03/29/2006 14:50:00 2.6 0.5 4.2 1.5 2.7 0.5 4.2 1.5 1.9 0.5 3 0.4 305 17 301 165 8.5 0.1 9 7.8 03/29/2006 15:00:00 2.7 0.8 4.6 0.4 2.7 0.8 4.6 0.7 2 0.6 3.8 0.4 304 19 304 165 8 0.1 8.5 7.5 03/29/2006 15:10:00 1.3 0.6 3 0.4 1.2 0.6 3 0.4 0.9 0.5 2.6 0.4 308 56 288 165 8.2 0.2 8.5 7.8 03/29/2006 15:20:00 1.7 0.6 3 0.4 1.7 0.6 3 0.4 1.2 0.5 2.6 0.4 304 18 289 165 8.1 0.2 8.5 7.5 03/29/2006 15:30:00 2.8 0.7 4.6 1.5 2.8 0.7 4.6 1.9 2.3 0.7 4.9 1.1 304 12 308 165 8.4 0.2 8.8 7.3 03/29/2006 15:40:00 3.8 0.8 5.3 1.9 3.8 0.8 5.3 1.9 3.4 0.8 4.9 1.1 311 6 309 165 7.6 0.3 8.3 7 03/29/2006 15:50:00 3.9 0.4 4.9 2.6 3.9 0.4 4.9 2.6 3.1 0.5 4.2 1.9 301 8 305 165 6.9 0.1 7.5 6.7 03/29/2006 16:00:00 3.8 0.7 5.7 1.9 3.8 0.7 5.7 1.9 3.1 0.8 4.9 1.1 305 11 300 165 7 0 7.3 6.7 03/29/2006 16:10:00 2.8 0.7 4.2 0.7 2.8 0.8 4.6 0.4 2 0.9 4.6 0.4 302 20 323 165 7.7 0.2 8.5 7.3 03/29/2006 16:20:00 3.1 1.2 5.3 0.4 3.1 1.2 5.3 0.4 2.3 1.1 5.3 0.4 294 23 296 165 7.9 0.5 8.5 7 03/29/2006 16:30:00 4.2 0.6 6.5 2.6 4.2 0.6 6.5 2.6 3.6 0.7 5.7 2.3 302 7 309 165 6.9 0.4 7.5 6.2 03/29/2006 16:40:00 4.1 0.5 4.9 2.6 4.1 0.5 5.3 2.6 3.5 0.6 4.9 2.3 307 5 308 165 6.6 0.1 7 6.2 03/29/2006 16:50:00 3.2 0.3 4.2 2.3 3.1 0.3 3.8 2.3 2.9 0.4 3.8 1.9 319 8 313 165 6.9 0.3 7.8 6.5 03/29/2006 17:00:00 3.7 0.5 4.6 2.3 3.7 0.5 4.6 2.3 3.1 0.6 4.9 1.9 306 8 301 165 6.7 0.4 7.8 6 03/29/2006 17:10:00 3.9 0.4 4.9 3 3.8 0.4 4.9 3 3.5 0.4 4.9 2.6 313 6 311 165 6.2 0 6.5 6 03/29/2006 17:20:00 3.4 0.6 4.9 1.5 3.4 0.6 4.9 1.5 3.1 0.6 4.6 1.5 315 15 338 165 6.1 0.2 6.5 5.7 03/29/2006 17:30:00 3.5 0.3 4.6 2.6 3.5 0.3 4.2 2.6 3.3 0.4 4.2 2.3 326 12 336 165 6.3 0.1 6.7 6 03/29/2006 17:40:00 3.8 0.4 4.9 3 3.8 0.4 4.9 2.6 3.3 0.4 4.2 2.3 308 5 309 165 5.6 0.2 6.2 5.2 03/29/2006 17:50:00 3.4 0.4 4.2 1.9 3.4 0.4 4.6 2.3 3.3 0.5 4.6 2.3 315 6 316 165 5.6 0 5.7 5.2 03/29/2006 18:00:00 3.2 0.4 4.2 2.3 3.2 0.4 4.2 2.3 3.1 0.4 4.2 1.9 320 9 310 165 5.8 0 6.2 5.7 03/29/2006 18:10:00 2.9 0.4 3.8 2.3 2.9 0.4 3.8 1.9 2.8 0.4 3.8 1.9 318 8 312 165 5.6 0 6 5.5 03/29/2006 18:20:00 2.9 0.4 3.8 1.9 3 0.4 3.8 1.9 2.9 0.4 3.8 1.9 317 8 313 165 5.4 0.2 6 5 03/29/2006 18:30:00 2.1 0.3 3 1.5 2.1 0.3 3 1.5 2.2 0.3 3 1.5 326 6 316 165 5.2 0 5.7 5 03/29/2006 18:40:00 1.8 0.3 3 1.1 1.8 0.3 3 1.1 1.6 0.3 2.6 1.1 311 10 303 165 4.9 0.2 5.5 4.5 03/29/2006 18:50:00 1.7 0.2 2.3 1.5 1.8 0.2 2.3 1.5 1.2 0.2 1.9 0.7 304 0 304 165 4.4 0 4.8 4.3 03/29/2006 19:00:00 2.1 0.2 2.6 1.5 2.1 0.2 2.6 1.5 1.5 0.2 2.3 1.1 303 1 304 165 4 0 4.5 3.8 03/29/2006 19:10:00 2.6 0.2 3.4 1.9 2.6 0.2 3.4 2.3 1.9 0.3 3 1.1 296 2 293 165 3.6 0.1 3.8 3.3 03/29/2006 19:20:00 2.4 0.4 3.4 1.5 2.4 0.4 3.4 1.5 1.7 0.3 2.6 1.1 298 2 298 165 3.1 0.1 3.5 3 03/29/2006 19:30:00 1.5 0.4 2.6 0.7 1.5 0.4 2.6 0.7 1.1 0.3 1.9 0.4 296 6 302 165 2.9 0 3 2.8 03/29/2006 19:40:00 2.1 0.6 3 0.7 2.2 0.5 3.4 1.1 1.7 0.6 3 0.7 293 5 302 165 2.9 0.1 3 2.6 03/29/2006 19:50:00 0.9 0.4 2.3 0.4 1.2 0.3 2.3 0.4 0.8 0.4 1.9 0.4 283 3 279 165 3 0 3.3 2.8 03/29/2006 20:00:00 1.4 0.2 2.3 0.7 1.6 0.2 2.3 1.1 1.2 0.3 2.3 0.7 287 6 277 165 3 0 3.3 2.8 03/29/2006 20:10:00 1.3 0.2 1.9 1.1 1.6 0.2 1.9 1.1 1.2 0.3 1.9 0.7 294 2 295 165 2.9 0 3.3 2.6 03/29/2006 20:20:00 1.6 0.4 2.3 0.7 1.8 0.3 2.3 1.1 1.5 0.2 1.9 0.7 299 2 302 165 2.7 0 2.8 2.6 03/29/2006 20:30:00 1.3 0.2 1.9 0.7 1.6 0.2 2.3 1.1 1.3 0.3 1.9 0.7 299 1 299 165 2.6 0 2.8 2.3 03/29/2006 20:40:00 1.7 0.3 2.6 1.1 2 0.3 2.6 1.5 1.6 0.3 2.3 0.7 300 5 296 165 2.6 0 2.8 2.3 03/29/2006 20:50:00 1.9 0.3 3 1.1 2.2 0.3 3 1.5 1.8 0.3 2.6 1.1 313 10 306 165 2.2 0.1 2.6 1.8 03/29/2006 21:00:00 1.9 0.5 3 0.4 2.1 0.5 3 1.1 2 0.5 3 1.1 315 10 325 165 2.2 0.2 2.6 1.8 03/29/2006 21:10:00 1.6 0.4 2.3 0.7 1.9 0.3 2.6 1.1 1.7 0.3 2.3 1.1 306 6 304 165 2.4 0 2.8 2.1 03/29/2006 21:20:00 1.9 0.4 3 1.1 2.1 0.4 3 1.5 1.5 0.3 2.3 0.7 297 5 300 165 2.4 0 2.6 2.3 03/29/2006 21:30:00 2.8 0.3 3.4 1.9 3 0.3 3.4 2.3 2.3 0.4 3 1.5 298 5 297 165 2.4 0 2.6 2.3 03/29/2006 21:40:00 2.2 0.4 3 1.1 2.5 0.4 3 1.5 1.9 0.4 3 0.7 302 4 306 165 2.3 0 2.6 2.1 03/29/2006 21:50:00 1.5 0.5 2.6 0.4 1.8 0.5 3 0.7 1.4 0.4 2.6 0.4 293 2 303 165 2.4 0 2.6 2.3 03/29/2006 22:00:00 0.5 0.3 1.5 0.4 0.6 0.4 1.9 0.4 0.6 0.4 1.9 0.4 271 13 292 165 2.4 0 2.6 2.3 03/29/2006 22:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 261 1 165 165 2.2 0 2.3 2.1 03/29/2006 22:20:00 0.4 0.1 1.1 0.4 0.4 0.2 1.1 0.4 0.4 0.2 1.1 0.4 227 22 212 165 2.4 0 2.8 2.1 03/29/2006 22:30:00 1 0.3 1.5 0.4 1.3 0.3 1.9 0.4 1.4 0.4 1.9 0.4 222 9 210 165 2.7 0 2.8 2.3 03/29/2006 22:40:00 1.1 0.3 1.9 0.7 1.4 0.3 2.3 1.1 1.6 0.2 2.3 1.1 213 7 206 165 2.4 0.1 2.8 2.1 03/29/2006 22:50:00 1.4 0.2 1.9 0.7 1.8 0.2 2.3 1.5 1.9 0.2 2.3 1.5 204 4 207 165 2.3 0 2.6 1.8 03/29/2006 23:00:00 1.1 0.2 1.5 0.7 1.5 0.2 1.9 1.1 1.6 0.2 2.3 1.1 203 3 205 165 2.2 0 2.3 1.8 03/29/2006 23:10:00 1.3 0.4 1.9 0.7 1.6 0.3 2.3 1.1 1.7 0.3 2.3 1.1 200 1 201 165 2.1 0 2.3 1.8 03/29/2006 23:20:00 1 0.4 1.5 0.4 1.4 0.3 1.9 0.7 1.5 0.3 2.3 0.7 200 1 199 165 2.1 0 2.3 1.6 03/29/2006 23:30:00 0.4 0 0.4 0.4 1.1 0.3 1.5 0.4 1.2 0.4 1.9 0.4 200 1 165 165 2 0 2.3 1.6 03/29/2006 23:40:00 1.2 0.3 1.9 0.4 1.6 0.2 2.3 1.1 1.7 0.3 2.3 1.1 203 4 208 165 2 0 2.3 1.6 03/29/2006 23:50:00 1.3 0.3 1.9 0.4 1.7 0.3 2.3 0.7 1.8 0.2 2.3 1.1 191 7 202 165 2.1 0 2.3 1.8 03/30/2006 00:00:00 1.9 0.3 2.6 1.1 2.2 0.2 2.6 1.5 2.3 0.2 2.6 1.5 189 2 189 165 2.2 0 2.3 1.8 03/30/2006 00:10:00 2 0.3 2.3 1.5 2.2 0.3 2.6 1.5 2.3 0.3 3 1.5 176 5 188 165 2.3 0 2.6 2.1 03/30/2006 00:20:00 2 0.2 2.6 1.5 2 0.2 2.6 1.5 2 0.2 2.6 1.5 168 3 174 165 2 0 2.3 1.6 03/30/2006 00:30:00 2.3 0.2 2.6 1.5 2.3 0.2 2.6 1.9 2.4 0.2 3 1.9 173 4 176 165 2.1 0.1 2.3 1.6 03/30/2006 00:40:00 2.1 0.2 2.6 1.5 2.2 0.2 2.6 1.5 2.2 0.2 2.6 1.9 164 8 165 165 2 0 2.3 1.6 03/30/2006 00:50:00 2.8 0.3 3.4 1.9 2.7 0.3 3.4 2.3 2.7 0.3 3.4 1.9 170 5 172 165 2 0 2.3 1.6 03/30/2006 01:00:00 2.4 0.4 3.4 1.5 2.5 0.3 3.4 1.9 2.4 0.3 3 1.9 175 6 176 165 1.9 0.1 2.1 1.4 03/30/2006 01:10:00 2.4 0.5 3 1.5 2.5 0.4 3 1.9 2.4 0.3 3 1.9 170 4 174 165 1.8 0 1.8 1.4 03/30/2006 01:20:00 2.4 0.3 3 1.5 2.6 0.3 3 1.9 2.6 0.3 3 1.9 171 5 167 165 1.8 0.1 2.1 1.4 03/30/2006 01:30:00 2.1 0.3 2.6 1.5 2.3 0.2 2.6 1.9 2.2 0.3 3 1.5 167 3 169 165 1.5 0.1 1.8 0.9 03/30/2006 01:40:00 2.9 0.4 3.8 1.9 3 0.4 3.8 2.3 3 0.4 3.8 2.3 178 10 192 165 1.5 0 1.8 0.9 03/30/2006 01:50:00 3.6 0.3 4.2 3 3.7 0.3 4.2 3 4 0.3 4.6 3.4 183 3 183 165 1.6 0 1.8 1.4 03/30/2006 02:00:00 4.4 0.3 5.3 3.8 4.3 0.3 4.9 3.8 4.5 0.3 4.9 3.4 166 5 164 165 1.4 0.1 1.6 1.1 03/30/2006 02:10:00 4.9 0.3 5.3 3.8 4.7 0.3 5.3 3.8 4.6 0.3 4.9 3.4 163 2 169 165 1.1 0 1.4 0.9 03/30/2006 02:20:00 5.3 0.4 6.1 4.6 5.1 0.4 5.7 4.2 5.1 0.3 5.7 4.2 161 13 157 165 1.2 0 1.6 1.1 03/30/2006 02:30:00 4.9 0.4 6.5 4.2 4.8 0.4 6.1 4.2 4.8 0.4 6.1 4.2 160 3 156 165 1.4 0 1.6 1.1 03/30/2006 02:40:00 6 0.8 7.6 2.3 5.8 0.7 7.2 2.6 5.9 0.7 7.6 3 157 7 160 165 1.4 0 1.6 1.1 03/30/2006 02:50:00 4.6 0.9 6.5 1.5 4.5 0.9 6.1 1.5 4.6 1 6.8 1.5 152 13 165 165 1.3 0.1 1.6 0.9 03/30/2006 03:00:00 4.3 0.8 6.5 2.6 4.3 0.7 6.1 2.6 4.4 0.6 6.1 3 155 11 147 165 1.1 0 1.4 0.9 03/30/2006 03:10:00 5.3 0.5 6.5 4.2 5.1 0.5 6.5 3.8 5.2 0.5 6.5 3.8 161 11 162 165 0.8 0 1.1 0.7 03/30/2006 03:20:00 4.7 0.7 6.8 3 4.5 0.7 6.5 3 4.7 0.7 6.5 3.4 160 5 161 165 0.6 0 0.9 0.4 03/30/2006 03:30:00 3.1 0.4 3.8 2.3 3.1 0.4 3.8 2.3 3.1 0.4 3.8 2.3 183 15 159 165 0.5 0 0.7 0.2 03/30/2006 03:40:00 3.4 0.5 4.9 2.3 3.6 0.6 5.3 2.3 3.5 0.6 5.3 2.3 206 6 218 165 0.6 0 0.9 0.4 03/30/2006 03:50:00 5.7 1.1 8 3 5.8 1 8 3.4 5.7 1.1 8 3.4 204 10 194 165 0.7 0 0.9 0.7 03/30/2006 04:00:00 6.7 0.6 8.8 5.3 6.7 0.6 8.8 5.3 6.6 0.6 8 4.9 197 4 193 165 0.5 0 0.9 0.2 03/30/2006 04:10:00 6.9 0.5 8.4 5.7 6.9 0.5 8.4 5.7 6.9 0.6 8.4 5.3 196 3 187 165 0.5 0 0.9 0.2 03/30/2006 04:20:00 7.3 0.5 8.8 6.1 7.4 0.5 8.8 6.1 7.4 0.5 8.8 5.7 198 4 198 165 0.2 0.2 0.7 -0.3 03/30/2006 04:30:00 7.8 0.7 9.5 6.1 7.7 0.7 9.5 6.1 7.9 0.8 9.5 6.1 191 5 191 165 0.5 0.1 0.7 -0.3 03/30/2006 04:40:00 8.4 0.7 10.3 6.5 8.1 0.6 9.5 6.5 8.5 0.7 10.3 6.8 180 5 177 165 0.4 0 0.7 0.2 03/30/2006 04:50:00 8.7 1.2 11.5 6.5 8.4 1.1 11.1 6.1 8.8 1.1 11.5 6.8 174 12 174 165 0.4 0.1 0.9 -0.1 03/30/2006 05:00:00 9 1 11.1 7.2 8.6 0.9 10.7 7.2 9.1 1 11.1 7.2 174 6 175 165 0.6 0 0.9 0.2 03/30/2006 05:10:00 8.7 0.8 11.5 6.5 8.4 0.8 11.1 6.8 8.8 0.8 11.1 6.5 177 7 185 165 0.7 0.2 0.9 0.2 03/30/2006 05:20:00 9.4 1.2 12.6 6.5 9.1 1.1 11.8 6.1 9.4 1.2 13 6.5 175 12 183 165 0.8 0.1 1.1 0.2 03/30/2006 05:30:00 10.3 1.7 13.3 6.5 10 1.6 13 6.1 10.5 1.7 13.7 6.8 169 7 168 165 0.8 0.1 1.4 0.4 03/30/2006 05:40:00 9.9 1.2 13 7.6 9.5 1.1 12.6 7.6 10.1 1.2 13.3 7.6 176 5 176 165 1 0 1.4 0.9 03/30/2006 05:50:00 8.9 0.6 10.3 6.8 8.5 0.6 9.9 6.8 9.1 0.6 10.7 7.2 175 5 176 165 0.9 0 1.4 0.7 03/30/2006 06:00:00 9 0.6 10.3 7.2 8.5 0.6 9.5 6.8 9.1 0.5 10.3 7.6 174 5 178 165 0.9 0.2 1.4 0.7 03/30/2006 06:10:00 8.4 0.7 10.3 6.8 8.1 0.6 9.9 6.5 8.7 0.7 10.7 6.8 173 8 178 165 1.2 0.2 1.6 0.7 03/30/2006 06:20:00 8.6 0.9 10.7 6.1 8.3 0.8 10.3 6.1 8.6 0.8 10.7 6.5 176 7 179 165 1.3 0.2 1.6 0.9 03/30/2006 06:30:00 9.5 1.1 11.5 6.5 9.4 1.1 11.1 6.1 9.6 1.1 12.2 6.5 185 6 183 165 1.3 0.2 1.6 0.9 03/30/2006 06:40:00 9.4 0.9 11.1 6.8 9.1 1 11.1 6.8 9.6 1.1 11.5 7.2 180 6 190 165 1.3 0.1 1.6 0.9 03/30/2006 06:50:00 6.2 0.8 8.4 4.6 6 0.8 8 4.6 6.4 0.8 8.4 4.9 174 6 172 165 1.3 0.1 1.6 0.9 03/30/2006 07:00:00 5.4 0.6 6.8 4.2 5.3 0.5 6.8 3.8 5.5 0.6 7.2 3.8 174 9 173 165 1.4 0.2 1.6 0.9 03/30/2006 07:10:00 5.6 0.8 8 3 5.5 0.8 7.6 3.4 5.9 0.8 8.4 3.8 174 9 192 165 1.4 0.2 1.6 0.9 03/30/2006 07:20:00 7.3 0.5 8.8 5.3 7.1 0.5 8.4 5.3 7.5 0.6 8.8 5.7 174 6 177 165 1.5 0.1 1.8 1.1 03/30/2006 07:30:00 7.9 0.6 9.1 5.7 7.6 0.6 9.1 5.3 8.1 0.6 9.9 6.5 173 5 166 165 1.6 0.1 1.8 1.4 03/30/2006 07:40:00 8.4 0.9 10.7 6.5 8.2 0.9 10.3 6.1 8.7 0.9 11.1 6.8 173 6 181 165 1.6 0.1 1.8 1.4 03/30/2006 07:50:00 8.4 0.8 10.7 6.5 8.2 0.8 10.7 6.1 8.6 0.8 11.1 6.8 175 12 183 165 1.6 0.1 1.8 1.4 03/30/2006 08:00:00 8.1 0.8 10.7 6.5 7.9 0.8 10.7 6.5 8.3 0.7 10.7 6.5 169 6 173 165 1.6 0.1 1.8 1.4 03/30/2006 08:10:00 9.9 1.3 13 6.8 9.7 1.3 13.7 7.2 10 1.1 13.7 7.2 183 12 190 165 1.8 0.1 1.8 1.6 03/30/2006 08:20:00 10.5 1 13 7.2 10.3 1 12.6 7.2 10.7 1.1 13 7.6 187 5 189 165 1.8 0.1 2.1 1.4 03/30/2006 08:30:00 8 1.1 11.1 5.7 7.7 1 11.1 5.3 8.2 1 11.8 5.7 179 8 174 165 1.6 0.1 1.8 1.1 03/30/2006 08:40:00 10.3 0.7 12.6 8 10 0.7 12.2 8 10.6 0.8 12.6 8 170 5 165 165 1.6 0.2 1.8 1.4 03/30/2006 08:50:00 11.9 0.7 13.7 9.5 11.5 0.7 13 9.1 12.2 0.8 14.1 9.5 167 5 165 165 1.6 0.2 1.8 1.4 03/30/2006 09:00:00 12.5 0.8 14.9 10.3 12.2 0.8 14.1 10.3 12.7 1 14.9 10.3 167 9 165 165 1.5 0.2 1.8 1.1 03/30/2006 09:10:00 13.6 0.7 15.6 11.5 13.2 0.7 15.3 11.1 13.9 0.7 15.3 11.8 167 11 167 165 1.5 0.2 1.8 1.1 03/30/2006 09:20:00 11.3 0.9 13 9.1 10.9 0.8 12.6 9.1 11.5 0.9 13.3 9.5 166 8 164 165 1.5 0.2 1.8 1.1 03/30/2006 09:30:00 11.4 0.6 13 9.5 11 0.6 12.2 9.1 11.8 0.6 13.3 9.9 168 11 167 165 1.5 0.2 1.8 0.9 03/30/2006 09:40:00 11.3 0.7 13 9.5 11 0.7 12.6 9.1 11.5 0.8 13.3 9.1 167 11 161 165 1.7 0.3 2.1 1.1 03/30/2006 09:50:00 12 0.6 13.7 10.3 11.7 0.6 13 9.9 12.4 0.6 13.7 10.7 163 13 165 165 1.7 0.2 2.1 1.4 03/30/2006 10:00:00 13.2 0.7 14.9 11.1 12.8 0.6 14.5 11.1 13.6 0.7 15.6 11.1 167 13 165 165 1.7 0.2 2.1 1.4 03/30/2006 10:10:00 12.4 1 14.9 9.9 12 1 14.1 9.5 12.7 1 14.9 9.5 170 4 165 165 1.7 0.2 1.8 1.4 03/30/2006 10:20:00 11 1.3 14.5 8.4 10.6 1.3 13.7 8 11.2 1.2 14.5 8.8 172 10 170 165 1.8 0.1 2.1 1.4 03/30/2006 10:30:00 12.8 0.8 14.5 9.9 12.4 0.7 14.1 9.9 13.1 0.9 14.9 11.1 170 5 165 165 1.8 0.1 2.1 1.4 03/30/2006 10:40:00 12.9 0.9 14.9 10.7 12.6 0.8 14.1 9.9 13.2 1 15.3 10.3 168 15 165 165 1.8 0 1.8 1.4 03/30/2006 10:50:00 14.2 1 16.4 11.1 13.8 0.9 15.6 11.1 14.6 1 16.8 10.7 168 14 169 165 1.7 0 1.8 1.4 03/30/2006 11:00:00 12.8 0.8 14.5 10.7 12.4 0.8 14.1 10.3 13 1 14.5 10.7 166 16 169 165 1.6 0 2.1 1.4 03/30/2006 11:10:00 13.8 0.7 15.6 11.1 13.3 0.6 14.9 11.1 14 0.8 15.3 11.1 167 11 165 165 1.6 0 1.8 1.4 03/30/2006 11:20:00 13.2 0.7 14.9 11.1 12.8 0.6 14.5 11.1 13.5 0.7 15.3 11.5 167 10 172 165 1.7 0 1.8 1.4 03/30/2006 11:30:00 12.5 0.7 14.1 10.7 12 0.6 13.7 10.3 12.7 0.8 14.5 11.1 167 3 165 165 1.7 0 1.8 1.4 03/30/2006 11:40:00 12 0.5 13 10.3 11.6 0.4 12.6 10.3 12.4 0.5 13.7 10.3 168 5 172 165 1.5 0.1 1.8 1.1 03/30/2006 11:50:00 11.3 0.5 12.6 9.9 11 0.5 12.2 9.5 11.6 0.6 13 9.5 165 7 165 165 1.5 0 1.8 1.1 03/30/2006 12:00:00 12 0.4 13 10.7 11.6 0.4 12.6 10.3 12.3 0.5 13.3 10.3 166 14 164 165 1.5 0.1 1.8 0.9 03/30/2006 12:10:00 11.4 0.5 12.6 9.9 11.1 0.4 12.2 9.5 11.7 0.6 13 9.9 164 5 164 165 1.5 0.2 1.8 0.9 03/30/2006 12:20:00 9.6 0.6 11.1 7.6 9.4 0.6 11.1 7.6 9.9 0.7 11.5 8.4 162 13 159 165 1.5 0.1 1.8 0.9 03/30/2006 12:30:00 10.9 1.6 14.5 8.4 10.8 1.6 14.1 8 11.1 1.6 14.9 8.8 156 6 157 165 1.6 0.2 1.8 0.9 03/30/2006 12:40:00 13.4 0.5 14.5 11.8 13.4 0.5 14.5 11.8 13.8 0.6 14.9 11.5 152 2 151 165 1.7 0.1 1.8 1.4 03/30/2006 12:50:00 14.2 0.8 16.4 11.8 14.2 0.7 16.1 11.5 14.7 0.8 16.4 11.8 152 4 162 165 1.7 0.1 1.8 1.4 03/30/2006 13:00:00 14.4 0.9 16.8 11.8 14.2 0.8 16.4 11.5 14.6 0.8 17.2 12.2 153 5 152 165 1.7 0 2.3 1.4 03/30/2006 13:10:00 13.9 1 16.1 10.3 13.7 1 16.1 10.7 14 1 16.8 10.7 154 6 152 165 1.8 0 1.8 1.4 03/30/2006 13:20:00 14.5 0.7 16.8 12.6 14.3 0.7 16.8 12.2 14.6 0.8 16.8 11.8 154 5 163 165 1.8 0 1.8 1.4 03/30/2006 13:30:00 14.2 0.9 16.4 11.1 13.8 0.9 16.1 11.5 14.2 1 16.4 11.5 156 4 148 165 1.7 0 1.8 1.6 03/30/2006 13:40:00 13 0.6 14.5 11.1 12.8 0.6 14.5 11.1 12.9 0.6 14.1 11.1 152 3 152 165 1.7 0 1.8 1.6 03/30/2006 13:50:00 12.6 0.7 14.5 10.3 12.5 0.7 14.5 10.7 12.4 0.9 14.1 9.1 150 3 156 165 1.7 0 1.8 1.6 03/30/2006 14:00:00 12.4 0.5 13.7 11.5 12.3 0.5 14.1 11.1 12.4 0.6 13.7 9.9 156 2 150 165 1.7 0 1.8 1.6 03/30/2006 14:10:00 12.7 0.7 14.5 9.9 12.6 0.7 14.5 9.9 12.5 1 14.9 9.5 157 0 157 165 1.8 0 1.8 1.6 03/30/2006 14:20:00 12.8 1.3 16.1 9.5 12.8 1.3 16.1 9.5 12.7 1.3 16.1 10.3 156 0 157 165 1.8 0 1.8 1.6 03/30/2006 14:30:00 14.7 1 17.2 11.8 14.6 1 17.2 11.5 15.3 1.3 18.7 12.2 155 3 153 165 1.8 0 1.8 1.6 03/30/2006 14:40:00 15.1 1 17.2 12.2 14.7 1 16.8 11.8 15.8 1.1 18.3 12.2 157 11 155 165 1.8 0 2.1 1.6 03/30/2006 14:50:00 16 0.9 18.3 13.7 15.8 0.8 17.9 13.3 15.9 1.1 17.9 12.2 156 12 160 165 1.8 0 2.1 1.6 03/30/2006 15:00:00 16.1 0.8 17.9 13.7 15.8 0.8 17.6 13.3 16.4 0.9 17.9 14.1 157 9 159 165 1.8 0 1.8 1.6 03/30/2006 15:10:00 15 0.7 17.2 12.2 14.8 0.6 16.8 12.2 15.2 0.8 17.6 12.6 155 2 153 165 1.8 0 1.8 1.6 03/30/2006 15:20:00 14.5 0.6 15.6 12.6 14.4 0.6 16.1 12.6 14.7 0.8 16.1 12.6 153 2 149 165 1.8 0 1.8 1.6 03/30/2006 15:30:00 13.9 0.7 15.6 11.5 13.8 0.7 15.6 11.5 14.3 0.8 16.1 12.2 155 0 156 165 1.7 0 1.8 1.4 03/30/2006 15:40:00 12.9 0.7 14.9 10.7 12.8 0.8 14.5 10.3 12.9 1 15.3 10.3 155 0 155 165 1.7 0 1.8 1.4 03/30/2006 15:50:00 12.3 0.6 13.7 10.3 12.3 0.6 13.7 10.3 12.4 0.7 14.1 9.9 154 0 154 165 1.8 0 1.8 1.4 03/30/2006 16:00:00 12.2 0.6 14.1 9.9 12 0.7 13.7 9.5 12.3 0.7 14.5 11.1 154 0 154 165 1.8 0 1.8 1.4 03/30/2006 16:10:00 12.3 0.8 14.1 9.9 12.1 0.8 14.1 9.9 12.2 1 14.1 9.1 154 0 154 165 1.8 0 1.8 1.4 03/30/2006 16:20:00 12.9 0.7 14.1 11.1 12.6 0.7 14.1 10.3 12.7 1 14.5 9.5 154 0 154 165 1.7 0 1.8 1.4 03/30/2006 16:30:00 12.6 0.8 14.5 10.3 12.3 0.7 14.5 10.3 12.4 0.8 14.1 10.3 154 0 154 165 1.7 0 1.8 1.4 03/30/2006 16:40:00 12.9 0.8 14.9 10.7 12.5 0.8 14.5 10.3 12.4 1 14.5 9.5 154 0 154 165 1.8 0 1.8 1.4 03/30/2006 16:50:00 12.9 0.8 14.9 10.7 12.6 0.8 14.5 10.3 12.6 1 14.9 9.5 154 0 154 165 1.8 0 1.8 1.1 03/30/2006 17:00:00 13.2 1.1 15.3 10.3 12.9 1 14.9 9.9 12.9 1.2 15.3 9.1 154 0 154 165 1.8 0 1.8 1.4 03/30/2006 17:10:00 13.2 0.9 14.9 10.3 12.8 0.8 14.5 9.9 13 0.9 14.9 10.7 154 0 154 165 1.8 0 1.8 1.4 03/30/2006 17:20:00 12.5 1 14.5 9.1 12.2 0.9 13.7 8.8 12.3 1.1 14.5 8.8 154 0 154 165 1.7 0 1.8 1.4 03/30/2006 17:30:00 13.2 1.1 15.6 10.3 12.8 1.1 14.9 10.3 13 1.3 15.6 8.8 154 0 154 165 1.8 0 1.8 1.4 03/30/2006 17:40:00 13 0.9 14.9 9.5 12.6 0.9 14.9 9.1 12.9 1.1 15.3 9.5 154 0 154 165 1.8 0 1.8 1.1 03/30/2006 17:50:00 13.3 1 14.9 11.1 12.9 1 14.5 10.7 13.1 1.2 15.3 9.9 154 0 154 165 1.8 0 1.8 1.6 03/30/2006 18:00:00 12.9 1.1 15.6 9.1 12.6 1 15.6 9.5 12.7 1.3 15.6 8 154 0 154 165 1.8 0 1.8 1.6 03/30/2006 18:10:00 13.5 0.8 15.3 11.5 13 0.8 14.9 11.1 13.2 0.9 15.3 11.1 154 0 154 165 1.8 0 1.8 1.6 03/30/2006 18:20:00 13.7 0.7 15.3 11.5 13.1 0.7 14.5 10.7 13.3 1 15.3 9.5 154 0 154 165 1.8 0 1.8 1.6 03/30/2006 18:30:00 13.6 1 15.6 11.1 13.1 0.9 15.3 10.7 13 1 15.3 9.9 154 0 154 165 1.7 0 1.8 1.6 03/30/2006 18:40:00 12.7 1 14.9 9.9 12.3 0.9 14.1 10.3 12 1 14.1 9.1 154 0 154 165 1.7 0 1.8 1.6 03/30/2006 18:50:00 13.6 0.7 15.3 11.5 13.1 0.6 14.5 11.5 12.9 0.8 14.9 10.7 154 0 154 165 1.8 0 1.8 1.6 03/30/2006 19:00:00 13.6 1 15.6 11.1 12.9 0.9 14.9 10.7 12.8 1.1 15.3 10.3 154 0 154 165 1.7 0 1.8 1.6 03/30/2006 19:10:00 13.9 0.8 15.6 11.8 13.1 0.8 14.9 11.1 13.2 1.1 15.6 10.3 154 0 154 165 1.8 0 1.8 1.6 03/30/2006 19:20:00 13.1 0.9 14.9 9.9 12.3 0.8 14.5 9.5 12.1 1.4 14.5 7.2 154 0 154 165 1.8 0 1.8 1.6 03/30/2006 19:30:00 13.3 1.1 15.3 10.7 12.7 1 14.5 10.3 12.6 1.2 14.9 10.3 154 0 154 165 1.7 0 1.8 1.6 03/30/2006 19:40:00 13.6 0.9 15.3 10.7 13 0.9 14.9 10.3 13.1 1 14.9 9.9 154 0 154 165 1.7 0 1.8 1.6 03/30/2006 19:50:00 13.7 0.6 14.9 11.8 13 0.6 14.5 11.5 13.4 0.8 15.3 11.5 154 0 155 165 1.7 0 1.8 1.6 03/30/2006 20:00:00 12.7 0.8 14.9 10.3 11.8 0.7 14.1 9.5 12.5 1 14.9 9.5 154 0 154 165 1.8 0 1.8 1.6 03/30/2006 20:10:00 13 0.9 14.9 10.3 12.2 0.9 14.5 9.5 13 1 15.3 9.9 154 0 154 165 1.7 0 1.8 1.6 03/30/2006 20:20:00 11.8 0.7 13.3 9.9 10.9 0.6 12.6 8.8 11.9 0.9 13.7 8.8 154 0 154 165 1.7 0 1.8 1.6 03/30/2006 20:30:00 12 0.7 13.3 9.1 8 1 11.1 7.2 12.1 1 14.1 8.4 154 0 154 165 1.7 0 1.8 1.6 03/30/2006 20:40:00 12.4 0.7 14.5 10.7 7.4 0.2 7.6 7.2 12.9 1 14.9 9.5 154 0 154 165 1.7 0 1.8 1.6 03/30/2006 20:50:00 11.4 1 13.3 7.2 8 0.6 9.1 6.8 11.8 1.2 13.7 7.6 154 0 154 165 1.5 0 1.8 1.4 03/30/2006 21:00:00 11.4 0.7 13 9.5 8.5 0.2 8.8 7.6 11.7 1 13.7 9.1 154 0 154 165 1.5 0 1.6 1.4 03/30/2006 21:10:00 11.5 0.7 13.3 9.5 8.3 0.3 8.8 7.6 11.6 1 14.1 8.8 154 0 154 165 1.5 0 1.6 1.4 03/30/2006 21:20:00 11.5 1 13.3 8.4 8.1 0.2 8.8 7.6 11.4 1.2 13.3 6.8 154 0 154 165 1.5 0 1.6 1.4 03/30/2006 21:30:00 12.6 1.1 14.5 9.1 8.1 0.2 8.4 7.6 10.7 2.2 14.1 7.6 154 0 154 165 1.5 0 1.6 1.4 03/30/2006 21:40:00 13 0.7 14.5 11.1 7.9 0.2 8.4 7.2 7.8 0.2 8 7.2 154 0 154 165 1.5 0 1.6 1.4 03/30/2006 21:50:00 13.1 0.8 14.9 10.3 7.8 0.2 8.4 6.8 7.6 0.2 8 6.8 154 0 154 165 1.5 0 1.6 1.4 03/30/2006 22:00:00 13.1 0.7 14.5 10.7 7.7 0.3 8 6.8 7.4 0.2 8 6.8 154 0 154 165 1.4 0 1.8 1.4 03/30/2006 22:10:00 12.8 0.6 14.1 11.1 7.9 0.3 8.4 6.8 7.3 0.2 7.6 6.8 154 0 154 165 1.3 0 1.6 1.1 03/30/2006 22:20:00 12.8 0.6 14.5 11.1 8 0.2 8.4 6.8 7.3 0.2 7.6 6.8 154 0 154 165 1.4 0 1.6 1.4 03/30/2006 22:30:00 13 0.7 14.5 11.1 7.9 0.2 8.4 7.2 7.2 0.2 7.6 6.8 154 0 154 165 1.3 0 1.6 1.1 03/30/2006 22:40:00 12.4 0.6 14.1 10.7 7.7 0.3 8.4 6.8 7.1 0.2 7.6 6.8 154 0 154 165 1.1 0 1.4 0.9 03/30/2006 22:50:00 12.2 0.5 13.3 11.1 7.5 0.4 8.4 6.8 7 0.2 7.2 6.5 154 0 154 165 1 0 1.4 0.9 03/30/2006 23:00:00 11.6 0.9 13 8.4 7.3 0.3 8 6.5 6.9 0.2 7.2 6.5 154 0 154 165 0.9 0 1.1 0.9 03/30/2006 23:10:00 12 0.4 13 10.7 7.4 0.3 8 6.8 6.8 0.2 7.2 6.5 154 0 154 165 1 0 1.4 0.9 03/30/2006 23:20:00 11.7 0.6 13 9.9 7.2 0.2 8 6.5 6.7 0.2 6.8 6.1 154 0 154 165 1.1 0 1.4 0.9 03/30/2006 23:30:00 11.8 0.7 13 8.4 7.2 0.2 8 6.5 6.6 0.2 6.8 6.1 154 0 154 165 1.1 0 1.4 0.9 03/30/2006 23:40:00 11.2 0.5 12.6 9.9 7 0.2 7.6 6.5 6.4 0.2 6.8 6.1 154 0 154 165 1.2 0 1.4 1.1 03/30/2006 23:50:00 11.5 0.8 12.6 8.8 7 0.2 7.6 6.5 6.4 0.2 6.8 6.1 154 0 154 165 1.2 0 1.4 1.1 03/31/2006 00:00:00 10.9 1 13 8.4 6.9 0.2 7.2 6.5 6.3 0.2 6.8 5.7 154 0 154 165 1.2 0 1.4 0.9 03/31/2006 00:10:00 9.1 0.9 11.5 8 6.7 0.2 7.2 6.1 6.2 0.2 6.8 5.7 154 0 154 165 1.1 0 1.4 0.9 03/31/2006 00:20:00 9.8 1.3 11.8 7.2 6.6 0.2 7.2 6.1 6.1 0.2 6.5 5.7 154 0 154 165 1.1 0 1.4 0.9 03/31/2006 00:30:00 9.1 0.7 10.7 7.2 6.6 0.2 7.2 6.1 6 0.2 6.5 5.7 154 0 154 165 1.1 0 1.4 0.9 03/31/2006 00:40:00 10.2 0.5 11.1 8.8 6.5 0.2 6.8 6.1 5.9 0.2 6.5 5.3 154 0 154 165 1.2 0 1.4 1.1 03/31/2006 00:50:00 9.9 0.6 11.5 7.6 6.4 0.2 6.8 5.7 5.8 0.4 6.5 3.8 154 0 154 165 1.2 0 1.4 1.1 03/31/2006 01:00:00 9.7 0.6 11.1 8 6.3 0.2 6.8 6.1 5.9 0.2 6.1 5.3 154 0 154 165 1.1 0 1.4 0.9 03/31/2006 01:10:00 9 1.1 11.1 6.5 6.4 0.3 7.2 5.7 5.9 0.2 6.1 5.7 154 0 154 165 1.1 0 1.4 0.9 03/31/2006 01:20:00 7.6 0.3 8.4 6.5 6.3 0.3 6.8 5.3 5.8 0.2 6.1 5.3 154 0 154 165 1.2 0 1.4 0.9 03/31/2006 01:30:00 7.6 0.2 8 6.8 6.2 0.2 6.8 5.7 5.6 0.2 6.1 4.9 154 0 154 165 1.2 0 1.4 1.1 03/31/2006 01:40:00 7.4 0.3 8.4 6.5 6.1 0.2 6.5 4.9 5.6 0.2 6.1 4.9 154 0 154 165 1.2 0 1.4 1.1 03/31/2006 01:50:00 7.5 0.2 8 6.8 6.1 0.2 6.5 5.3 5.4 0.2 5.7 4.9 154 0 154 165 1.2 0 1.4 1.1 03/31/2006 02:00:00 8 0.8 9.9 6.8 6.2 0.2 6.8 5.3 5.4 0.2 6.1 4.9 154 0 154 165 1.4 0 1.6 1.4 03/31/2006 02:10:00 7.8 0.8 9.9 6.5 6 0.2 6.5 5.3 5.3 0.3 6.1 4.2 154 0 154 165 1.4 0 1.6 1.4 03/31/2006 02:20:00 7.3 0.2 8 6.5 4.9 0.8 6.5 3.4 5.1 0.3 5.7 4.2 154 0 154 165 1.5 0 1.6 1.4 03/31/2006 02:30:00 8.1 1 9.9 6.8 4.8 0.6 6.1 3 5 0.3 5.7 4.2 154 0 154 165 1.6 0 1.8 1.4 03/31/2006 02:40:00 8.3 1 9.9 6.8 5.1 0.3 6.1 4.6 4.9 0.4 5.7 3.8 154 0 154 165 1.5 0.1 1.6 1.4 03/31/2006 02:50:00 6.9 0.3 7.6 6.5 4.7 0.6 6.1 3.4 4 0.9 5.7 1.9 154 0 154 165 1.4 0 1.6 1.4 03/31/2006 03:00:00 7 0.2 7.2 6.5 4.6 0.5 5.7 3 3.3 0.9 5.3 1.5 154 0 155 165 1.4 0 1.6 1.4 03/31/2006 03:10:00 7.7 1.2 10.7 6.5 4.7 0.5 6.5 3.4 0.6 0.6 3 0.4 154 0 154 165 1.4 0 1.6 1.4 03/31/2006 03:20:00 9.3 0.6 10.7 7.2 4.7 0.3 5.3 3.8 0.4 0 0.4 0.4 154 0 154 165 1.4 0 1.6 1.4 03/31/2006 03:30:00 8.9 1 10.3 6.1 4.6 0.4 5.7 3.4 0.4 0 0.4 0.4 154 0 154 165 1.4 0 1.6 1.4 03/31/2006 03:40:00 9.1 0.6 10.3 6.8 4.4 0.3 5.3 3.4 0.4 0 0.4 0.4 154 0 154 165 1.5 0 1.6 1.4 03/31/2006 03:50:00 9.3 0.6 10.7 7.6 4.2 0.4 4.9 3 0.4 0 0.4 0.4 154 0 154 165 1.5 0 1.6 1.4 03/31/2006 04:00:00 8.5 1.6 10.7 5.7 4.4 0.3 5.7 3.8 0.4 0 0.4 0.4 154 0 154 165 1.4 0 1.6 1.4 03/31/2006 04:10:00 5.6 0.3 6.5 4.9 3.9 0.4 4.6 2.6 0.4 0 0.4 0.4 154 0 154 165 1.4 0 1.6 1.4 03/31/2006 04:20:00 5.4 0.2 6.1 4.9 4 0.4 4.6 2.3 0.4 0 0.4 0.4 154 0 154 165 1.4 0 1.6 1.4 03/31/2006 04:30:00 5.2 0.2 6.1 4.6 3.4 0.5 4.6 2.3 0.4 0 0.4 0.4 154 0 154 165 1.3 0 1.4 1.4 03/31/2006 04:40:00 5.4 0.2 6.1 4.9 3.5 0.5 4.6 2.3 0.4 0 0.4 0.4 154 0 154 165 1.4 0 1.6 1.1 03/31/2006 04:50:00 5.4 0.2 5.7 4.9 2.9 0.4 4.2 1.9 0.4 0 0.4 0.4 154 0 154 165 1.4 0 1.6 1.4 03/31/2006 05:00:00 5.2 0.2 5.7 4.9 2.7 0.3 3.8 1.9 0.4 0 0.4 0.4 154 0 154 165 1.4 0 1.6 1.4 03/31/2006 05:10:00 5.2 0.2 5.7 4.6 2.6 0.4 3.8 1.5 0.4 0 0.4 0.4 154 0 154 165 1.4 0 1.6 1.4 03/31/2006 05:20:00 5.1 0.2 5.7 4.6 2.4 0.3 3 1.1 0.4 0 0.4 0.4 154 0 154 165 1.5 0 1.6 1.4 03/31/2006 05:30:00 5 0.2 5.3 4.6 2 0.3 2.6 1.1 0.4 0 0.4 0.4 154 0 154 165 1.6 0 1.8 1.4 03/31/2006 05:40:00 5 0.2 5.3 4.6 2.4 0.4 3.4 1.1 0.4 0 0.4 0.4 154 0 154 165 1.7 0 1.8 1.4 03/31/2006 05:50:00 4.8 0.2 5.3 4.2 1.2 0.9 3 0.4 0.4 0 0.4 0.4 154 0 154 165 1.7 0 1.8 1.4 03/31/2006 06:00:00 4.6 0.3 4.9 3.8 0.4 0 0.4 0.4 0.4 0 0.4 0.4 154 0 154 165 1.7 0 1.8 1.6 03/31/2006 06:10:00 4.5 0.2 4.9 3.8 0.4 0 0.4 0.4 0.4 0 0.4 0.4 154 0 154 165 1.7 0 1.8 1.6 03/31/2006 06:20:00 4.3 0.2 4.9 3.8 0.4 0 0.4 0.4 0.4 0 0.4 0.4 154 0 154 165 1.7 0 1.8 1.6 03/31/2006 06:30:00 4.3 0.3 4.9 3.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 154 0 154 165 1.7 0 1.8 1.6 03/31/2006 06:40:00 4.2 0.2 4.6 3.8 0.4 0 0.4 0.4 0.4 0 0.4 0.4 154 0 154 165 1.7 0 1.8 1.6 03/31/2006 06:50:00 4.1 0.2 4.6 3.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 154 0 154 165 1.7 0 1.8 1.6 03/31/2006 07:00:00 3.9 0.3 4.6 3 0.4 0 0.4 0.4 0.4 0 0.4 0.4 154 3 154 165 1.8 0 1.8 1.6 03/31/2006 07:10:00 3.8 0.4 4.6 2.3 0.4 0 0.4 0.4 0.4 0 0.4 0.4 154 4 155 165 1.8 0 1.8 1.6 03/31/2006 07:20:00 3.8 0.4 4.2 2.3 0.4 0 0.4 0.4 0.4 0 0.4 0.4 150 5 149 165 1.8 0 1.8 1.6 03/31/2006 07:30:00 3.8 0.2 4.2 2.6 0.4 0 0.4 0.4 0.4 0 0.4 0.4 150 5 145 165 1.8 0 1.8 1.6 03/31/2006 07:40:00 3.7 0.3 4.2 3 0.4 0 0.4 0.4 0.4 0 0.4 0.4 151 5 151 165 1.8 0 1.8 1.6 03/31/2006 07:50:00 3.1 0.3 3.8 2.3 0.4 0 0.4 0.4 0.4 0 0.4 0.4 150 4 153 165 1.8 0 1.8 1.6 03/31/2006 08:00:00 2.7 0.2 3 2.3 0.4 0 0.4 0.4 0.4 0 0.4 0.4 152 4 153 165 1.8 0 1.8 1.6 03/31/2006 08:10:00 2.9 0.3 3.4 1.9 0.4 0 0.4 0.4 0.4 0 0.4 0.4 150 4 147 165 1.8 0 1.8 1.6 03/31/2006 08:20:00 2.8 0.2 3.4 2.3 0.4 0 0.4 0.4 0.4 0 0.4 0.4 152 5 153 165 1.8 0 1.8 1.6 03/31/2006 08:30:00 3 0.4 3.8 2.3 0.4 0 0.4 0.4 0.4 0 0.4 0.4 151 4 150 165 1.9 0 1.8 1.8 03/31/2006 08:40:00 3.6 0.4 4.2 2.6 0.4 0 0.4 0.4 2.4 1.1 3.8 0.4 152 5 149 165 1.9 0 2.1 1.6 03/31/2006 08:50:00 3.5 0.3 4.2 2.6 0.4 0 0.4 0.4 3 0.2 3.8 2.3 153 4 153 165 1.9 0 2.1 1.8 03/31/2006 09:00:00 3.4 0.4 4.2 2.6 0.4 0 0.4 0.4 2.9 0.2 3.4 2.3 149 5 159 165 2 0 2.1 1.8 03/31/2006 09:10:00 3.6 0.3 4.2 2.6 3.4 1.1 4.6 0.4 2.9 0.2 3.4 2.6 149 4 143 165 2 0 2.1 1.8 03/31/2006 09:20:00 3.4 0.3 4.2 2.6 3.7 0.3 4.6 3 2.9 0.2 3.4 2.6 150 5 156 165 2 0 2.3 1.8 03/31/2006 09:30:00 3.5 0.3 4.2 2.6 3.2 0.4 3.8 2.3 3 0.3 3.4 2.3 150 4 144 165 2.1 0 2.3 1.8 03/31/2006 09:40:00 3.6 0.4 4.9 2.6 3.2 0.5 4.6 2.3 3.2 0.2 3.8 2.6 151 5 163 165 2.1 0 2.3 1.8 03/31/2006 09:50:00 3.7 0.3 4.6 3 2.8 0.3 3.4 2.3 3.3 0.2 3.8 2.6 147 4 153 165 2.2 0 2.3 2.1 03/31/2006 10:00:00 4 0.4 4.9 3 2.8 0.4 4.2 2.3 3.5 0.3 4.6 3 147 4 151 165 2.2 0 2.3 2.1 03/31/2006 10:10:00 3.8 0.3 4.6 3 2.3 0.2 2.6 1.9 3.6 0.3 4.2 3 148 4 153 165 2.3 0 2.3 2.1 03/31/2006 10:20:00 3.4 0.6 4.2 1.9 2.2 0.2 2.6 1.9 5 1.4 6.8 2.6 148 4 142 165 2.3 0 2.6 2.3 03/31/2006 10:30:00 3.2 0.8 4.6 1.9 2.3 0.2 3 1.9 5.9 0.5 6.8 4.2 147 5 158 165 2.4 0 2.8 2.3 03/31/2006 10:40:00 2.2 0.4 3.8 1.5 2.4 0.2 3 1.9 6.2 0.4 6.8 4.9 147 4 150 165 2.6 0 2.8 2.6 03/31/2006 10:50:00 3.5 1 4.9 1.5 2.9 0.7 4.6 1.9 6 0.4 6.8 4.6 147 4 143 165 2.9 0 3 2.6 03/31/2006 11:00:00 9.8 3.1 14.1 4.2 3.6 0.4 4.6 3 6.4 0.4 7.2 5.3 147 4 144 165 2.9 0 3 2.8 03/31/2006 11:10:00 12.2 1 14.1 8.8 4.8 1 6.8 3.4 8.4 2.4 14.5 5.7 148 4 145 165 3 0 3.3 2.8 03/31/2006 11:20:00 12.2 1 14.1 8.8 6.3 0.4 7.2 4.9 12 1.1 14.1 8.4 146 5 148 165 3 0 3.3 2.8 03/31/2006 11:30:00 11.9 0.8 13.7 9.9 6.4 0.4 7.2 5.3 11.6 0.9 14.1 8.4 145 5 145 165 3.1 0 3.3 2.8 03/31/2006 11:40:00 11.2 0.8 13 8.8 8.1 2.6 12.2 4.9 11 0.9 13.3 8.8 144 4 143 165 3.1 0 3.3 3 03/31/2006 11:50:00 10.5 0.9 12.2 8 10.4 0.9 12.6 8 10.3 0.9 12.2 7.6 146 4 146 165 3.1 0 3.3 3 03/31/2006 12:00:00 10 0.6 11.5 8.4 9.9 0.6 11.5 8 9.7 0.8 11.5 7.6 146 4 150 165 3.1 0 3.3 3 03/31/2006 12:10:00 9.6 0.7 11.5 6.8 9.6 0.7 11.1 6.8 9.4 0.8 11.1 6.8 147 5 147 165 3.2 0 3.5 3 03/31/2006 12:20:00 8.5 0.7 9.9 6.1 8.4 0.7 9.9 6.1 8.2 0.8 9.9 6.1 145 5 147 165 3.4 0 3.5 3.3 03/31/2006 12:30:00 7.5 0.8 9.1 5.3 7.4 0.8 9.1 4.9 7.2 0.8 9.1 5.3 145 4 143 165 3.5 0 3.8 3.3 03/31/2006 12:40:00 6 0.6 7.6 3.8 5.9 0.6 7.2 3.8 5.8 0.6 7.2 3.4 143 4 145 165 3.7 0 3.8 3.5 03/31/2006 12:50:00 5.5 0.5 6.5 4.6 5.4 0.5 6.5 4.6 5.4 0.5 6.5 3.8 148 5 145 165 3.6 0 3.8 3.5 03/31/2006 13:00:00 5.1 0.3 5.7 4.2 4.9 0.3 5.3 4.2 5 0.3 5.7 4.2 153 2 149 165 3.7 0 3.8 3.5 03/31/2006 13:10:00 4.2 0.3 4.9 3.4 4.1 0.3 4.9 3.4 4.3 0.3 4.9 3.4 154 3 154 165 3.8 0 4 3.5 03/31/2006 13:20:00 4.1 0.4 4.9 3 3.9 0.4 4.9 3 4 0.4 4.9 3 152 4 158 165 4 0.1 4.3 3.5 03/31/2006 13:30:00 3.3 0.5 4.6 1.9 3.1 0.5 4.6 1.9 3.3 0.5 4.6 1.9 148 8 161 165 4.1 0.1 4.5 3.5 03/31/2006 13:40:00 3.4 0.5 4.6 1.9 3.3 0.5 4.6 1.1 3.3 0.5 4.2 1.9 142 5 145 165 4 0 4.3 3.5 03/31/2006 13:50:00 3.4 0.5 4.9 2.3 3.3 0.5 4.9 2.3 3.2 0.6 4.9 1.9 144 8 144 165 4 0.1 4.3 3.5 03/31/2006 14:00:00 3.4 0.5 5.3 1.9 3.4 0.5 4.9 1.9 3.2 0.5 4.9 1.9 133 10 126 165 4.2 0.1 4.5 3.5 03/31/2006 14:10:00 3.1 0.5 4.6 1.5 3.1 0.5 4.6 1.5 2.9 0.5 4.2 1.5 138 15 114 165 4.5 0.1 4.8 4 03/31/2006 14:20:00 2.5 0.6 4.2 1.1 2.5 0.6 4.2 1.1 2.2 0.5 3.8 0.7 116 17 122 165 5.1 0.3 5.7 4.5 03/31/2006 14:30:00 2.8 0.7 5.3 0.7 2.7 0.7 4.9 0.7 2.5 0.6 3.8 1.1 139 13 143 165 5.2 0.2 5.5 4.8 03/31/2006 14:40:00 3.4 0.5 4.6 2.3 3.3 0.5 4.6 1.9 3.4 0.5 4.9 1.9 150 8 145 165 4.8 0.2 5.2 4.5 03/31/2006 14:50:00 3.3 0.6 5.3 2.3 3.3 0.6 4.9 2.3 3.5 0.5 4.6 2.3 145 9 162 165 4.8 0.2 5.2 4.3 03/31/2006 15:00:00 3.1 0.6 4.9 1.5 2.9 0.7 4.9 1.1 3.2 0.6 4.6 1.5 153 10 144 165 4 0 4.5 3.5 03/31/2006 15:10:00 4.3 1.9 8.4 0.7 4.3 2.1 8.4 0.4 3.9 1.6 7.6 0.7 272 58 288 165 3.2 0.4 4 2.1 03/31/2006 15:20:00 8.2 1 10.3 5.3 8.1 1 10.3 5.3 6.6 0.8 9.1 4.6 298 7 301 165 2.4 0 2.6 2.1 03/31/2006 15:30:00 10.5 1.5 13.3 7.6 10.5 1.5 13.7 7.6 8.3 1.2 12.6 5.7 303 7 302 165 1.9 0.2 2.3 1.4 03/31/2006 15:40:00 10.2 0.9 12.6 8 10.1 0.9 12.2 7.6 7.6 0.8 9.9 5.7 301 5 294 165 1.7 0.1 2.3 1.4 03/31/2006 15:50:00 10.1 1.3 13.7 6.8 10 1.3 13.7 6.8 7.6 1.2 10.7 4.9 302 5 303 165 1.7 0 1.8 1.1 03/31/2006 16:00:00 10.1 1 11.8 6.8 10 1 11.8 6.8 7.7 1.1 10.3 5.7 303 4 304 165 1.7 0 1.8 1.6 03/31/2006 16:10:00 10.6 1.2 14.9 7.6 10.6 1.2 14.5 7.6 8.9 1.4 13.3 6.1 306 4 302 165 1.7 0 1.8 1.4 03/31/2006 16:20:00 12.7 1 14.9 10.3 12.7 1 15.3 9.9 11.3 1.2 13.7 8 307 3 305 165 1.6 0 1.8 0.9 03/31/2006 16:30:00 12.5 1.2 14.9 9.9 12.4 1.2 15.3 9.9 11.6 1.2 14.9 8.4 310 2 310 165 1.2 0 1.4 0.9 03/31/2006 16:40:00 13 1.4 16.1 9.1 12.9 1.4 16.1 9.1 11.9 1.5 15.3 8 308 2 309 165 1.1 0 1.4 0.9 03/31/2006 16:50:00 13.4 1 15.3 10.3 13.4 1 15.3 10.3 11.8 1.1 14.5 9.1 307 2 306 165 1.1 0 1.4 0.9 03/31/2006 17:00:00 14.3 1.2 16.8 10.3 14.3 1.3 16.8 10.3 12.4 1.3 15.3 9.1 306 0 306 165 1.1 0 1.4 0.9 03/31/2006 17:10:00 14.6 0.7 16.1 12.2 14.6 0.7 16.1 11.8 12.7 1.2 14.9 8 306 0 306 165 1.2 0 1.4 0.9 03/31/2006 17:20:00 13.8 1.2 16.4 10.7 13.8 1.3 16.4 10.7 10.4 1.4 14.9 7.6 302 3 306 165 1.4 0 1.6 1.4 03/31/2006 17:30:00 13.1 1 15.3 10.7 13 1 15.3 10.3 9.5 1 12.2 6.5 298 3 300 165 1.4 0 1.6 1.4 03/31/2006 17:40:00 12.5 1.2 14.9 9.5 12.4 1.2 14.9 9.1 9.2 1.1 12.6 6.5 301 3 299 165 1.4 0 1.6 1.4 03/31/2006 17:50:00 12.8 1 15.6 10.3 12.7 1 15.6 9.9 9.5 1.3 15.3 6.8 301 3 305 165 1.4 0 1.6 1.4 03/31/2006 18:00:00 13.2 1.3 16.4 8.8 13.1 1.3 16.1 8.8 10.3 1.5 15.6 6.1 307 4 301 165 1.5 0 1.8 1.4 03/31/2006 18:10:00 13 1.5 17.2 8.8 12.8 1.5 16.8 8.4 10.5 1.5 14.9 6.5 307 4 298 165 1.6 0 1.8 1.4 03/31/2006 18:20:00 13.1 1.5 16.4 9.5 13 1.5 16.4 9.1 10.2 1.4 13.7 6.8 304 3 302 165 1.4 0 1.6 1.4 03/31/2006 18:30:00 14.3 1.2 17.9 11.1 14.2 1.2 17.6 11.1 10.5 1.2 14.1 7.6 299 4 302 165 1.2 0 1.4 1.1 03/31/2006 18:40:00 15.1 1.1 17.6 11.1 15.1 1.1 17.2 11.5 11.3 1.5 15.3 7.2 297 4 300 165 1.1 0 1.4 0.9 03/31/2006 18:50:00 15.4 0.9 17.9 13 15.4 1 17.9 13 11.5 1.3 16.4 8.4 297 2 297 165 1.1 0 1.4 0.9 03/31/2006 19:00:00 14.5 1.6 17.9 10.7 14.4 1.6 17.9 10.7 11 1.5 15.6 7.2 296 3 298 165 0.8 0 1.1 0.7 03/31/2006 19:10:00 14.2 1.2 16.8 11.5 14.2 1.3 16.8 10.7 11 1.6 16.4 7.6 297 2 299 165 0.7 0 0.9 0.7 03/31/2006 19:20:00 14.6 1.3 17.6 11.1 14.6 1.3 17.2 11.1 12.2 1.7 16.8 8 292 4 289 165 0.5 0 0.7 0.2 03/31/2006 19:30:00 14.3 1.3 17.9 11.1 14.2 1.4 17.9 10.3 11 1.5 16.4 7.6 295 4 292 165 0.4 0 0.7 0.2 03/31/2006 19:40:00 14.2 1.5 17.2 10.7 14.1 1.5 17.2 10.3 10.7 1.3 14.9 7.6 299 2 299 165 0.4 0 0.7 0.2 03/31/2006 19:50:00 15.1 1.6 18.7 10.7 15 1.7 18.7 10.7 11.6 1.5 16.8 7.6 298 4 302 165 0.5 0 0.7 0.2 03/31/2006 20:00:00 15.3 1.3 19.1 11.5 15.2 1.3 19.5 11.5 11.8 1.6 16.4 8.4 298 5 299 165 0.5 0 0.7 0.2 03/31/2006 20:10:00 14.7 1.8 18.7 9.5 14.6 1.8 19.1 9.9 11.3 1.6 16.1 7.6 298 5 291 165 0.4 0 0.7 0.2 03/31/2006 20:20:00 16 1.6 20.2 11.8 15.9 1.7 20.2 11.5 11.8 1.6 16.1 6.8 299 4 303 165 0.4 0 0.7 0.2 03/31/2006 20:30:00 15.8 1.5 19.1 10.7 15.8 1.5 19.1 10.7 12.1 1.9 17.9 8 297 5 291 165 0.4 0 0.7 0.2 03/31/2006 20:40:00 16 1.5 19.5 11.5 16 1.5 19.1 11.5 12.2 1.6 17.2 8.4 297 4 298 165 0.4 0 0.7 0.2 03/31/2006 20:50:00 16.1 1.3 18.7 11.8 16.1 1.3 18.7 12.2 12.1 1.5 17.2 8 296 4 296 165 0.3 0 0.7 0.2 03/31/2006 21:00:00 14.4 1.4 18.3 10.7 14.5 1.5 18.7 10.7 12.4 2.2 18.7 8 293 5 294 165 0.3 0 0.7 0.2 03/31/2006 21:10:00 14.8 1.7 19.5 10.3 14.7 1.7 19.5 10.7 12 1.7 19.5 8.4 294 6 297 165 0.3 0 0.7 0.2 03/31/2006 21:20:00 15.8 1.4 18.7 11.5 15.8 1.5 18.7 11.5 11.9 1.4 15.6 8.4 299 5 303 165 0.4 0 0.7 0.2 03/31/2006 21:30:00 13.9 1.5 17.6 9.9 13.8 1.6 17.9 9.5 11 1.6 15.6 7.6 295 6 297 165 0.3 0 0.7 0.2 03/31/2006 21:40:00 14.2 1.3 17.9 11.1 14.2 1.3 17.6 10.7 12 1.7 17.2 8.4 293 5 301 165 0.3 0 0.7 0.2 03/31/2006 21:50:00 15.3 1.1 17.9 12.6 15.4 1.1 17.9 12.2 13.6 1.6 17.6 9.5 290 3 286 165 0.2 0 0.4 0.2 03/31/2006 22:00:00 14.4 1.1 17.6 10.3 14.5 1.2 17.6 9.9 12.5 1.7 17.2 7.6 290 3 286 165 0.1 0 0.2 -0.1 03/31/2006 22:10:00 13.1 1.7 16.8 9.1 13 1.7 16.8 9.1 10 1.5 14.5 6.5 299 6 291 165 0.1 0 0.2 -0.1 03/31/2006 22:20:00 11.8 1.6 16.1 7.2 11.7 1.6 16.1 7.2 8.9 1.5 14.5 5.7 302 5 304 165 0.1 0 0.2 -0.1 03/31/2006 22:30:00 11.6 1.8 17.6 5.7 11.6 1.8 18.3 5.3 9.4 1.8 16.4 5.7 301 8 302 165 0.4 0 0.7 0.2 03/31/2006 22:40:00 11.4 1.7 16.8 7.6 11.3 1.7 16.8 7.6 8.9 1.5 13.7 5.3 299 7 300 165 0.2 0.1 0.7 -0.1 03/31/2006 22:50:00 11.5 1.7 17.2 6.8 11.5 1.7 17.2 6.8 10.1 1.9 16.4 4.9 295 8 307 165 0 0 0.2 -0.1 03/31/2006 23:00:00 10.7 1.3 16.4 8 10.6 1.3 16.4 7.6 9 1.5 14.1 5.3 294 7 295 165 0.2 0 0.4 -0.1 03/31/2006 23:10:00 10.7 1.2 13.7 6.8 10.5 1.2 13.3 6.8 9 1.6 13.3 4.6 292 6 295 165 0.1 0 0.2 -0.1 03/31/2006 23:20:00 10 1.8 15.6 6.5 9.9 1.7 15.3 6.1 8.4 1.7 13.7 4.6 293 7 300 165 0.1 0 0.2 -0.1 03/31/2006 23:30:00 9.6 1.8 14.9 5.3 9.5 1.8 14.9 4.9 8.1 1.9 14.5 4.2 296 9 318 165 0.4 0.1 0.7 0.2 03/31/2006 23:40:00 10.3 1.9 15.3 6.1 10.2 1.9 15.3 5.7 8.7 1.9 14.1 4.9 295 9 296 165 0.2 0 0.4 0.2 03/31/2006 23:50:00 9.9 1.7 15.3 5.7 9.8 1.7 14.9 5.3 8.6 1.8 13.7 4.9 293 8 297 165 0.2 0.1 0.7 0.2 04/01/2006 00:00:00 9.6 1.7 14.1 5.3 9.6 1.7 14.1 5.7 8.4 1.7 12.6 4.2 292 8 299 165 0.1 0 0.2 -0.1 04/01/2006 00:10:00 8 1.3 11.5 4.6 7.9 1.3 11.5 4.6 7 1.2 10.7 4.6 305 13 291 165 0.1 0 0.2 -0.1 04/01/2006 00:20:00 7.1 1.5 10.7 3.8 7 1.4 10.7 4.2 6 1.2 9.5 3 306 13 302 165 0.2 0 0.4 -0.1 04/01/2006 00:30:00 7.7 1.3 13 4.2 7.6 1.2 13 4.2 6.8 1.1 10.3 4.2 305 13 291 165 0.3 0 0.7 -0.1 04/01/2006 00:40:00 8.7 1.5 12.2 4.6 8.7 1.5 12.2 4.6 7.1 1.2 11.1 3.8 298 9 302 165 0.2 0 0.7 -0.1 04/01/2006 00:50:00 10.1 1.2 13 6.1 10.1 1.2 12.6 6.1 8.3 1.5 12.6 4.9 293 6 298 165 0.1 0 0.2 -0.1 04/01/2006 01:00:00 10.5 1.5 14.1 7.2 10.5 1.5 14.1 6.8 8.9 1.9 14.1 4.9 293 6 288 165 0.1 0 0.2 -0.1 04/01/2006 01:10:00 11.4 1.3 15.6 7.6 11.5 1.2 15.3 7.6 9.5 1.5 13.7 6.1 293 6 292 165 0.2 0 0.2 -0.1 04/01/2006 01:20:00 10.9 1.3 14.1 6.8 10.9 1.3 14.5 7.2 9.1 1.4 14.9 5.7 295 6 283 165 0.2 0 0.2 -0.1 04/01/2006 01:30:00 11.3 1.5 15.6 6.8 11.3 1.5 15.3 6.5 8.9 1.6 15.6 4.9 296 5 290 165 0.1 0 0.2 -0.1 04/01/2006 01:40:00 11.5 1.5 15.3 6.8 11.5 1.6 15.3 6.5 9.4 1.7 14.1 4.9 293 6 307 165 0.2 0 0.2 -0.1 04/01/2006 01:50:00 11 2.1 16.8 6.1 11 2 16.4 6.1 9.3 2.1 15.6 3.8 295 7 293 165 0.2 0 0.2 -0.1 04/01/2006 02:00:00 12.6 1.2 16.1 9.5 12.5 1.2 16.1 9.9 10 1.5 13.7 6.8 295 5 295 165 0.1 0 0.2 0.2 04/01/2006 02:10:00 12.8 1.2 17.2 9.5 12.8 1.2 16.4 9.5 10 1.4 13.7 6.5 296 5 298 165 0.2 0 0.4 -0.1 04/01/2006 02:20:00 12.2 1.6 15.3 7.2 12.1 1.6 15.6 7.6 9.6 1.5 14.5 6.1 296 5 285 165 0.2 0 0.4 0.2 04/01/2006 02:30:00 11.8 1.4 14.9 8 11.7 1.4 14.5 8 9.6 1.6 13.7 6.1 295 6 299 165 0.2 0 0.7 0.2 04/01/2006 02:40:00 10.3 1.7 14.1 6.1 10.3 1.6 13.7 6.1 8.4 1.6 14.1 4.6 298 8 293 165 0.3 0 0.7 0.2 04/01/2006 02:50:00 10 1.5 13.3 6.1 10 1.5 13.7 6.1 8.2 1.5 13 4.2 295 8 302 165 0.4 0.1 0.7 0.2 04/01/2006 03:00:00 9.3 1.5 13.7 5.3 9.3 1.5 13.7 5.3 8 1.5 13 4.2 294 9 288 165 0.4 0 0.7 0.2 04/01/2006 03:10:00 10.2 1.5 14.5 6.8 10.1 1.5 14.1 7.2 8 1.4 12.6 4.2 300 8 293 165 0.5 0 0.7 0.2 04/01/2006 03:20:00 9.9 2 14.1 4.9 9.8 1.9 13.7 5.3 7.9 1.8 13 3.4 300 8 312 165 0.6 0 0.9 0.4 04/01/2006 03:30:00 11.1 1.3 15.3 6.8 11 1.3 15.3 7.2 8.5 1.5 13 4.9 299 5 298 165 0.5 0 0.9 0.2 04/01/2006 03:40:00 11.4 1.7 16.1 7.2 11.3 1.7 15.6 7.2 8.9 1.5 15.3 5.7 301 7 306 165 0.2 0.1 0.7 0.2 04/01/2006 03:50:00 12 1.8 17.2 6.5 11.8 1.8 16.8 6.5 9.2 1.5 13.7 4.6 302 7 301 165 0.1 0 0.2 -0.1 04/01/2006 04:00:00 11.8 1.7 16.1 7.6 11.7 1.7 15.6 7.6 9.4 1.6 15.6 6.1 305 6 307 165 0.3 0 0.7 -0.1 04/01/2006 04:10:00 10.3 1.7 14.1 5.7 10.1 1.7 13.3 5.7 8.1 1.5 11.8 4.9 302 7 291 165 0.4 0 0.7 0.2 04/01/2006 04:20:00 9.9 1.5 13.3 5.7 9.7 1.5 13 6.1 7.7 1.3 11.1 4.2 299 8 292 165 0.3 0.1 0.7 0.2 04/01/2006 04:30:00 11.6 1.4 15.3 8 11.5 1.4 14.5 8 9 1.3 12.6 5.7 299 7 303 165 0.2 0 0.4 -0.1 04/01/2006 04:40:00 9.9 1.5 14.1 6.5 9.8 1.5 14.1 6.1 7.6 1.5 11.1 4.2 299 7 298 165 0.1 0 0.4 -0.1 04/01/2006 04:50:00 9.6 1.6 13.7 4.9 9.6 1.6 14.1 5.7 7.6 1.5 12.6 4.2 298 6 293 165 0.1 0 0.2 -0.3 04/01/2006 05:00:00 9.5 1.3 13.3 5.7 9.4 1.3 13 6.1 7.8 1.2 11.1 3.8 295 6 294 165 0.1 0 0.2 -0.1 04/01/2006 05:10:00 10.7 1.3 13.3 6.8 10.6 1.2 13.3 6.5 8.4 1.3 13 5.3 295 5 296 165 -0.1 0 0.2 -0.1 04/01/2006 05:20:00 9.9 1.5 13.3 5.7 9.8 1.5 13 6.1 7.8 1.2 11.8 4.6 299 7 301 165 -0.1 0 -0.1 -0.3 04/01/2006 05:30:00 11.5 1.5 14.9 7.2 11.5 1.5 14.9 7.2 8.7 1.3 12.6 5.3 299 7 298 165 -0.1 0 0.2 -0.3 04/01/2006 05:40:00 10.3 1.8 13.7 4.9 10.3 1.8 13.3 4.9 8.1 1.5 11.8 4.2 302 7 297 165 0 0 0.2 -0.1 04/01/2006 05:50:00 10.7 1.8 14.5 6.5 10.6 1.8 14.1 6.1 8.2 1.5 11.8 4.9 304 6 304 165 0 0 0.2 -0.1 04/01/2006 06:00:00 11.9 1.3 15.6 8.8 11.8 1.3 15.6 8.8 9.4 1.3 12.6 6.1 303 6 307 165 -0.1 0 0.2 -0.1 04/01/2006 06:10:00 12.3 1.5 15.6 8.4 12.2 1.5 15.6 8 9.6 1.2 13.7 6.5 303 6 307 165 -0.1 0 0.2 -0.3 04/01/2006 06:20:00 12.3 1.5 16.1 8 12.2 1.5 16.1 8 9.9 1.4 13 6.5 305 7 307 165 -0.1 0 0.2 -0.1 04/01/2006 06:30:00 13.2 1.4 17.2 9.5 13.1 1.4 16.8 9.1 10.6 1.3 15.3 7.6 305 6 310 165 0 0 0.2 -0.1 04/01/2006 06:40:00 13.8 1.7 17.6 10.3 13.7 1.7 17.2 9.9 10.8 1.3 14.5 7.6 304 6 302 165 -0.1 0 -0.1 -0.3 04/01/2006 06:50:00 13.8 1.5 17.6 9.1 13.7 1.5 17.2 9.5 10.4 1.4 15.3 7.2 303 5 305 165 -0.1 0 -0.1 -0.3 04/01/2006 07:00:00 13.7 1.7 17.6 9.5 13.7 1.7 17.2 9.1 11 1.7 16.4 7.6 305 6 300 165 -0.2 0 -0.1 -0.3 04/01/2006 07:10:00 13.8 1.1 16.4 10.3 13.7 1.1 16.1 9.9 11.7 1.3 15.3 8.4 308 6 305 165 -0.3 0 -0.1 -0.3 04/01/2006 07:20:00 13.6 1.3 16.8 9.1 13.4 1.3 16.8 9.5 11.3 1.5 16.1 7.6 307 5 311 165 -0.3 0 -0.1 -0.5 04/01/2006 07:30:00 13.7 1.5 16.8 9.5 13.6 1.5 16.8 9.5 11.3 1.5 15.6 7.6 307 5 305 165 -0.3 0 -0.1 -0.5 04/01/2006 07:40:00 13.7 1.5 16.8 9.9 13.6 1.5 16.8 10.3 11.6 1.5 14.9 7.6 308 5 307 165 -0.3 0 -0.1 -0.5 04/01/2006 07:50:00 14.5 1.3 17.9 11.1 14.5 1.2 17.6 11.1 12.5 1.4 15.6 9.1 308 5 303 165 -0.3 0 -0.1 -0.3 04/01/2006 08:00:00 14 1.5 17.6 10.7 13.9 1.5 17.6 10.3 11.6 1.5 15.3 8.4 307 5 310 165 -0.3 0 -0.1 -0.5 04/01/2006 08:10:00 14.6 1.7 18.7 10.3 14.5 1.7 18.3 9.5 13 1.8 17.6 8.4 310 6 301 165 -0.3 0 -0.1 -0.3 04/01/2006 08:20:00 14.6 1.6 18.7 11.1 14.5 1.7 18.7 11.1 12.8 1.6 16.4 8.4 308 5 308 165 -0.2 0 -0.1 -0.3 04/01/2006 08:30:00 14.3 1.3 17.2 11.1 14.1 1.4 17.2 10.7 12.4 1.4 15.3 8.8 309 6 310 165 -0.2 0 -0.1 -0.3 04/01/2006 08:40:00 14 1.4 17.2 9.9 13.9 1.5 17.6 9.5 12.2 1.5 17.6 8 309 5 311 165 -0.1 0 0.2 -0.3 04/01/2006 08:50:00 14.7 1.5 17.2 10.3 14.6 1.5 17.2 10.3 11.3 1.5 15.3 7.6 303 6 301 165 0 0 0.2 -0.1 04/01/2006 09:00:00 13.6 1.4 16.8 9.9 13.6 1.5 17.2 9.5 10.5 1.4 15.3 7.6 303 6 309 165 -0.1 0 0.2 -0.1 04/01/2006 09:10:00 13.2 1.3 16.4 9.1 13.2 1.3 15.6 9.1 9.8 1.2 13.3 6.5 302 6 297 165 -0.1 0 0.2 -0.1 04/01/2006 09:20:00 12.9 1.6 16.1 8.4 12.9 1.6 16.4 8.4 10 1.4 14.1 6.5 301 6 305 165 -0.1 0 0.2 -0.1 04/01/2006 09:30:00 13.7 1.2 17.2 9.9 13.6 1.3 17.6 9.9 11.1 1.3 14.9 8 304 5 324 165 0.1 0 0.2 -0.1 04/01/2006 09:40:00 14 1.3 16.8 9.1 13.9 1.3 16.4 9.5 11.1 1.3 14.9 8 304 6 307 165 0 0 0.2 -0.1 04/01/2006 09:50:00 13 1.7 16.4 8.4 12.9 1.7 16.4 8 10.6 1.7 14.9 6.1 305 6 310 165 0.1 0 0.2 -0.1 04/01/2006 10:00:00 12.7 1.7 16.8 8 12.6 1.7 16.8 8 10 1.4 13.7 6.8 303 6 304 165 0.2 0 0.4 0.2 04/01/2006 10:10:00 13.1 1.3 16.1 9.5 13.1 1.3 16.1 9.5 10 1.3 15.3 7.2 303 6 304 165 0.3 0 0.4 0.2 04/01/2006 10:20:00 13 1.2 15.6 9.1 12.9 1.2 15.6 8.8 9.7 1 12.6 6.5 300 6 298 165 0.2 0 0.4 0.2 04/01/2006 10:30:00 13.2 1.3 16.1 8.8 13.2 1.3 16.1 8.8 10.2 1.3 13.3 7.2 302 6 297 165 0.2 0 0.2 0.2 04/01/2006 10:40:00 13.3 1.2 16.8 9.1 13.2 1.3 16.8 9.1 9.9 1.1 13.3 6.8 300 5 300 165 0.2 0 0.4 0.2 04/01/2006 10:50:00 13.8 1.6 16.4 8.4 13.7 1.6 16.8 8.4 10.1 1.3 15.6 6.8 299 5 291 165 0.3 0 0.7 0.2 04/01/2006 11:00:00 14.2 1.1 16.8 11.1 14.2 1.2 17.2 11.5 10.1 1 13.3 7.2 300 4 299 165 0.4 0 0.7 0.2 04/01/2006 11:10:00 14.6 1.1 17.2 11.5 14.6 1.2 16.8 11.5 10.4 1 13.3 7.6 300 4 304 165 0.5 0 0.7 0.2 04/01/2006 11:20:00 13.4 1.1 16.1 10.3 13.4 1.1 16.1 9.9 10 1.3 14.1 7.2 302 5 305 165 0.7 0 0.9 0.4 04/01/2006 11:30:00 13.2 1.1 16.1 9.1 13.1 1.2 16.1 8.8 9.8 1 13 7.2 302 5 291 165 0.8 0 0.9 0.7 04/01/2006 11:40:00 12.7 1.3 15.3 9.1 12.7 1.3 15.3 9.1 9.6 1.1 13.3 6.8 302 6 305 165 0.8 0 0.9 0.7 04/01/2006 11:50:00 12.2 1.1 15.3 8.4 12.1 1.2 15.3 8.8 9.9 1.3 13.3 6.8 305 6 304 165 0.7 0 0.9 0.4 04/01/2006 12:00:00 12 0.8 14.5 9.5 12 0.8 14.5 9.1 9.4 1.2 13 6.5 305 5 304 165 0.7 0.1 0.9 0.4 04/01/2006 12:10:00 12.2 0.9 14.5 9.1 12.1 0.9 14.5 9.1 10 1.2 13.7 6.5 306 5 310 165 0.8 0 0.9 0.7 04/01/2006 12:20:00 11.8 1.3 14.1 8.4 11.8 1.3 14.5 8 9.5 1.3 13 6.1 307 4 307 165 0.9 0 1.4 0.7 04/01/2006 12:30:00 10.5 1.2 13 7.2 10.5 1.2 13 7.2 8.2 1 10.7 5.7 307 6 307 165 1.4 0.1 1.6 0.9 04/01/2006 12:40:00 10.5 0.9 12.2 8 10.4 0.9 12.6 7.6 8.6 1.2 11.8 5.7 308 5 310 165 1.2 0 1.6 0.9 04/01/2006 12:50:00 10.4 1.2 13 6.1 10.3 1.2 12.6 6.5 8.9 1.3 12.6 4.9 310 6 305 165 1.1 0.1 1.4 0.9 04/01/2006 13:00:00 10.6 1 12.6 7.6 10.5 0.9 12.6 7.2 9.9 1.3 12.6 6.1 314 6 313 165 1 0 1.4 0.9 04/01/2006 13:10:00 10.2 0.8 12.2 7.6 10.2 0.8 12.2 7.6 8.7 1.1 11.8 5.7 310 6 302 165 1.4 0 1.6 1.1 04/01/2006 13:20:00 9.9 0.9 11.8 6.8 9.8 0.9 11.8 6.8 8.8 1 11.1 5.7 311 6 312 165 1.5 0 1.6 1.4 04/01/2006 13:30:00 10.8 1.5 13.7 7.6 10.6 1.5 13.7 7.2 9.2 1.4 12.2 5.3 310 6 302 165 1.5 0 1.8 1.4 04/01/2006 13:40:00 9.9 1.2 12.6 6.8 9.8 1.2 12.6 6.5 9.3 1.3 13.3 5.3 317 8 316 165 1.7 0 1.8 1.4 04/01/2006 13:50:00 9.6 1.2 13 6.1 9.5 1.2 13.3 6.1 9 1.3 12.2 5.3 320 9 316 165 1.7 0 1.8 1.6 04/01/2006 14:00:00 8.9 1.3 11.8 4.9 8.9 1.3 11.8 4.6 8.1 1.3 11.5 4.6 321 12 312 165 1.8 0 2.3 1.6 04/01/2006 14:10:00 10.7 1.2 13.7 8 10.6 1.2 14.1 7.6 10 1.4 13.7 5.7 326 9 325 165 2.3 0.1 2.6 1.8 04/01/2006 14:20:00 9.8 1.9 14.5 6.1 9.7 1.8 14.1 5.7 9.3 2.2 14.9 5.3 327 10 328 165 2.4 0.1 3 2.3 04/01/2006 14:30:00 9.2 1.5 13.3 5.7 9.1 1.5 12.6 5.7 8.7 1.6 12.6 5.3 325 13 313 165 3.1 0 3.5 2.6 04/01/2006 14:40:00 9.5 1.3 14.5 6.5 9.4 1.3 13.7 6.1 9.2 1.5 14.9 6.5 326 11 322 165 3.1 0 3.5 2.8 04/01/2006 14:50:00 10 1 13 7.2 9.9 1 12.6 6.8 9.7 1 12.6 6.5 321 9 329 165 2.9 0.1 3.3 2.3 04/01/2006 15:00:00 12.1 1.3 15.3 8.8 11.9 1.3 15.3 8.8 11.5 1.6 14.5 8 317 6 308 165 2.7 0.1 3.3 2.1 04/01/2006 15:10:00 12.7 1.3 14.9 8.8 12.5 1.3 14.9 9.1 12.2 1.3 14.9 8 320 7 324 165 3 0.1 3.3 2.6 04/01/2006 15:20:00 13.7 0.9 15.6 9.9 13.4 1 15.3 9.5 12.5 1.1 14.5 9.1 314 4 310 165 2.7 0.2 3 2.1 04/01/2006 15:30:00 13.1 1.1 15.6 9.1 12.9 1.1 15.6 9.1 12.5 1.3 15.3 8.8 316 5 316 165 2.5 0 2.8 2.1 04/01/2006 15:40:00 12.2 1.2 14.9 8.8 12 1.2 14.5 8.8 11.8 1.3 14.5 8.4 317 6 325 165 2.6 0 2.8 2.3 04/01/2006 15:50:00 11.5 1 14.5 9.1 11.4 1 14.5 9.1 10.3 1 13 7.6 312 6 307 165 3.3 0.2 3.5 2.6 04/01/2006 16:00:00 10.3 1.2 13.7 6.8 10.2 1.1 13.3 6.5 9.6 1.3 13 6.1 314 9 315 165 3.1 0.2 3.5 2.6 04/01/2006 16:10:00 9.1 1.1 13 6.5 9 1.1 12.6 6.5 8.6 1.2 12.6 6.1 320 9 315 165 3.1 0.3 3.5 2.3 04/01/2006 16:20:00 7.7 1 11.1 4.9 7.6 1 11.1 4.9 7.1 0.9 10.3 4.6 315 9 309 165 3.3 0.2 3.8 2.8 04/01/2006 16:30:00 8 1.1 12.2 5.3 7.9 1.1 11.8 5.3 7.4 1 9.9 4.6 315 10 303 165 3.5 0.2 3.8 2.8 04/01/2006 16:40:00 8.1 1.1 11.1 5.3 8 1.1 10.7 5.3 7.7 1 11.1 4.9 322 9 319 165 3.2 0.2 3.8 2.6 04/01/2006 16:50:00 6.9 0.8 8.8 4.9 6.8 0.8 8.8 4.6 6.6 0.8 8.8 4.2 321 10 334 165 3.5 0.2 3.8 2.8 04/01/2006 17:00:00 6.3 0.8 8 3.8 6.1 0.8 8 3.8 5.9 0.8 8 3.4 324 13 326 165 3.8 0.2 4.3 3.3 04/01/2006 17:10:00 6.1 1 9.1 4.2 6 1.1 9.5 3.4 5.9 1 8.8 3.4 326 14 305 165 4 0 4.3 3.5 04/01/2006 17:20:00 5.8 0.8 7.6 3.4 5.4 0.9 7.2 3 5.6 0.7 7.6 3 339 15 324 165 4 0 4.3 3.5 04/01/2006 17:30:00 5.8 1 8 3.8 4.8 1.3 8.4 1.9 5.8 1 8 3.4 352 10 354 165 3.8 0.1 4.3 3 04/01/2006 17:40:00 5.2 0.7 7.2 3.4 4.7 0.8 6.8 2.6 5.1 0.9 8 3 341 23 358 165 3.8 0.1 4.5 3.5 04/01/2006 17:50:00 5.4 0.8 8.4 3 5.2 1 8.4 2.3 5.3 0.7 7.6 3.4 326 14 314 165 3.3 0.2 3.8 2.8 04/01/2006 18:00:00 5.3 0.6 6.8 3.4 5.2 0.7 6.8 3.4 5.2 0.6 6.8 3.4 331 9 334 165 3.4 0.2 3.5 2.8 04/01/2006 18:10:00 5.6 0.6 6.8 3.8 5.5 0.6 6.8 4.2 5.2 0.7 7.2 3.8 320 12 321 165 3.4 0 3.5 2.8 04/01/2006 18:20:00 6.9 0.8 8.8 4.9 6.8 0.8 8.8 4.9 6.4 0.8 8.4 4.2 312 7 308 165 2.8 0.2 3.3 2.3 04/01/2006 18:30:00 9 1.4 11.8 6.1 8.9 1.4 11.5 6.1 7.7 1.5 11.5 3.8 309 6 298 165 2.4 0.2 2.8 1.8 04/01/2006 18:40:00 10.7 0.8 12.6 8 10.6 0.8 12.6 8 10.1 0.9 12.2 7.6 315 4 311 165 2 0.1 2.3 1.4 04/01/2006 18:50:00 9.6 1 11.8 6.8 9.5 1 11.5 6.8 8.8 1 11.8 6.8 312 4 311 165 1.8 0 1.8 0.9 04/01/2006 19:00:00 8.1 0.7 10.3 6.8 8 0.7 10.3 6.5 7.8 0.7 9.5 5.7 318 5 317 165 1.5 0 1.8 1.4 04/01/2006 19:10:00 8.6 0.6 9.9 7.2 8.5 0.6 9.9 6.8 7.8 0.8 9.5 5.3 312 5 309 165 1.2 0 1.6 0.9 04/01/2006 19:20:00 7.9 0.9 9.9 5.7 7.8 0.9 9.9 5.7 7.2 1.1 9.5 4.6 312 6 315 165 0.8 0.1 1.1 0.7 04/01/2006 19:30:00 6.8 0.6 8.4 5.7 6.8 0.6 8.4 5.3 5.2 0.8 8 3 297 7 283 165 0.5 0 0.7 0.2 04/01/2006 19:40:00 7.1 1 9.5 4.9 7.1 1 9.5 4.9 5.9 1.4 9.5 3.4 294 8 286 165 0.3 0.1 0.7 0.2 04/01/2006 19:50:00 7.4 1 10.3 5.3 7.5 1 10.3 5.3 6.1 1.2 9.9 3.8 296 7 278 165 0.2 0 0.2 0.2 04/01/2006 20:00:00 5.1 1 6.8 3 5.1 1 6.8 2.6 4 0.9 6.5 1.9 300 7 310 165 -0.1 0.1 0.2 -0.3 04/01/2006 20:10:00 3.5 1.2 6.1 1.1 3.6 1.2 6.1 0.7 3.3 1 5.7 0.7 283 12 304 165 -0.1 0 0.2 -0.3 04/01/2006 20:20:00 4.9 0.9 6.8 2.6 4.8 0.9 6.8 2.6 4.1 0.8 6.1 1.9 297 10 295 165 -0.2 0 -0.1 -0.3 04/01/2006 20:30:00 5.1 0.7 6.8 3 5 0.8 6.5 3 4.1 0.6 5.7 2.6 302 8 292 165 -0.5 0 -0.3 -0.5 04/01/2006 20:40:00 4.4 0.7 6.8 3 4.4 0.7 6.8 3.4 3.7 0.7 5.7 2.3 306 8 298 165 -0.6 0 -0.3 -0.8 04/01/2006 20:50:00 5.7 0.6 7.6 3.8 5.7 0.6 7.6 4.2 4.9 0.6 6.5 3 307 7 312 165 -0.8 0 -0.5 -0.8 04/01/2006 21:00:00 5.6 0.5 6.8 4.2 5.7 0.5 6.8 4.2 4.7 0.7 6.5 3 295 8 298 165 -0.7 0 -0.5 -0.8 04/01/2006 21:10:00 5.3 0.3 6.5 4.6 5.4 0.3 6.5 4.6 5.1 0.5 6.1 3.4 286 4 291 165 -0.7 0 -0.5 -0.8 04/01/2006 21:20:00 5.7 0.5 7.2 4.2 5.7 0.5 7.2 4.6 4.4 0.6 6.5 3 299 5 293 165 -0.6 0 -0.3 -0.8 04/01/2006 21:30:00 6.5 0.8 8.4 4.6 6.6 0.8 8.4 4.6 5.7 1 8.4 3 291 7 294 165 -0.6 0 -0.5 -0.8 04/01/2006 21:40:00 6.8 1.3 10.3 3.4 6.8 1.3 10.7 3.4 5.9 1.5 10.3 3 290 7 287 165 -0.6 0.1 -0.3 -0.8 04/01/2006 21:50:00 6.2 1.1 9.1 3 6.5 0.9 8.8 4.6 6 1 8.4 3.8 278 9 285 165 -0.4 0 -0.3 -0.8 04/01/2006 22:00:00 4.6 0.9 7.2 1.9 5.1 0.9 7.2 2.3 4.9 0.8 7.2 2.6 253 10 251 165 -0.5 0 -0.3 -0.8 04/01/2006 22:10:00 3.1 1.4 5.7 0.4 3.1 1.5 5.7 0.4 3.2 1.4 6.1 0.4 215 20 234 165 -0.5 0 -0.3 -0.8 04/01/2006 22:20:00 5.6 2.3 9.9 0.4 6.3 2.5 9.5 0.4 5.7 2.1 9.5 0.7 267 22 284 165 -0.6 0 -0.5 -0.8 04/01/2006 22:30:00 7.1 0.9 8.8 4.9 7.2 0.9 9.1 4.9 6.4 1.2 8.8 3.8 291 8 300 165 -0.3 0.1 -0.1 -0.5 04/01/2006 22:40:00 6.5 1.4 9.1 3 7.1 0.8 8.8 5.3 7 0.9 9.1 4.9 274 7 281 165 -0.2 0 -0.1 -0.3 04/01/2006 22:50:00 5.1 1.2 8.8 2.3 5.8 1 8.8 3.8 5.6 1 8.8 3.4 261 10 271 165 0.1 0.2 0.7 -0.3 04/01/2006 23:00:00 3.5 1.2 6.5 0.4 3.7 1 6.5 0.7 3.6 0.9 6.5 1.1 242 22 286 165 0.2 0 0.7 -0.1 04/01/2006 23:10:00 4.2 0.8 6.5 2.3 4.4 0.7 6.5 2.6 4.4 0.6 6.5 2.6 248 12 244 165 -0.1 0.1 0.2 -0.3 04/01/2006 23:20:00 7.3 2.2 14.1 3 7.7 2.1 14.1 4.2 7.2 2 13.7 3.8 278 8 277 165 -0.2 0 0.2 -0.5 04/01/2006 23:30:00 9.9 1.2 13 6.5 9.9 1.1 13 6.5 8.6 1.3 12.2 4.9 292 7 284 165 0.1 0 0.2 -0.1 04/01/2006 23:40:00 11.2 1.5 14.9 7.6 11.1 1.5 14.5 7.6 8.9 1.2 12.6 6.1 302 7 290 165 0.1 0 0.2 -0.3 04/01/2006 23:50:00 13 1.2 16.1 9.9 12.9 1.2 16.1 10.3 10.1 1.2 13.7 6.8 305 6 294 165 0.1 0 0.2 -0.1 04/02/2006 00:00:00 13.1 1.2 16.8 10.7 13 1.2 16.8 10.3 10.3 1.4 15.6 7.2 303 7 319 165 0.2 0.1 0.7 -0.3 04/02/2006 00:10:00 13.3 1.4 17.6 9.9 13.2 1.4 17.6 9.9 10.4 1.6 15.6 6.8 302 7 302 165 0.6 0 0.9 0.2 04/02/2006 00:20:00 15.6 1.6 19.9 10.3 15.6 1.6 19.5 10.3 11.9 1.7 17.2 8.4 305 5 305 165 0.9 0 1.1 0.7 04/02/2006 00:30:00 12.4 1.4 16.8 9.1 12.3 1.5 17.2 8.8 10.3 1.7 15.6 6.8 306 7 298 165 0.7 0 0.9 0.7 04/02/2006 00:40:00 12.1 1.7 16.4 8.4 12 1.7 16.4 8.8 9.9 1.4 14.1 6.8 306 8 293 165 0.5 0 0.9 0.2 04/02/2006 00:50:00 13.4 1.5 16.8 9.9 13.4 1.5 16.4 9.9 10.8 1.5 15.3 6.8 304 8 305 165 0.4 0 0.7 0.2 04/02/2006 01:00:00 12.6 1.3 15.6 8.8 12.5 1.2 15.6 8.8 10 1.5 14.9 6.8 304 7 299 165 0.3 0.1 0.7 0.2 04/02/2006 01:10:00 13.5 1.3 16.4 9.1 13.4 1.3 16.8 9.1 12.1 1.8 16.4 8.4 312 7 323 165 0.2 0 0.4 0.2 04/02/2006 01:20:00 14 1.2 17.2 10.7 13.8 1.3 16.8 10.3 12.8 1.5 17.2 8.8 313 6 301 165 0.1 0 0.2 -0.1 04/02/2006 01:30:00 12.2 1.7 16.4 8.4 12.1 1.6 16.4 8 10.4 1.7 16.8 6.1 309 8 317 165 0.1 0.1 0.2 -0.1 04/02/2006 01:40:00 13.7 1.5 17.2 9.9 13.6 1.5 16.8 9.5 11.4 1.7 16.1 7.2 307 7 310 165 0.2 0 0.4 -0.1 04/02/2006 01:50:00 15.7 1.7 19.1 9.5 15.6 1.7 19.1 9.9 14.5 2.2 18.3 8.4 314 7 309 165 0.2 0 0.4 -0.1 04/02/2006 02:00:00 13.4 1.4 16.8 10.3 13.2 1.4 16.8 10.3 12.5 1.8 16.4 6.8 313 7 318 165 -0.1 0 0.2 -0.3 04/02/2006 02:10:00 11.3 1.1 14.9 8.4 11.2 1.1 14.9 8.8 10.2 1.1 14.1 8 312 7 305 165 -0.3 0.1 -0.1 -0.5 04/02/2006 02:20:00 12.5 1.3 16.1 8.4 12.4 1.3 16.4 8.4 10.9 1.3 15.3 6.8 309 7 312 165 -0.3 0.1 0.2 -0.5 04/02/2006 02:30:00 12.9 1.6 16.4 8.4 12.8 1.7 16.4 8 10.3 1.7 14.5 6.1 306 6 303 165 -0.1 0 0.2 -0.1 04/02/2006 02:40:00 10.5 1.5 14.9 7.2 10.5 1.5 14.9 7.2 8.8 1.5 15.6 4.9 306 8 302 165 -0.1 0 0.2 -0.3 04/02/2006 02:50:00 8.6 1.1 11.1 5.7 8.6 1.1 11.1 5.7 7 1.1 9.9 4.2 304 7 300 165 -0.2 0 -0.1 -0.3 04/02/2006 03:00:00 7.4 1.1 10.3 4.6 7.4 1.1 10.3 4.6 5.7 1.1 9.5 3 297 6 295 165 -0.3 0 -0.1 -0.5 04/02/2006 03:10:00 5.8 1 8.4 3.4 5.7 1 8 3.4 4.7 1 7.6 2.6 295 8 302 165 -0.3 0 -0.1 -0.5 04/02/2006 03:20:00 6.8 1 9.1 3.8 6.8 1.1 9.5 3.8 5.6 1 8.8 3 295 8 286 165 -0.3 0 -0.1 -0.5 04/02/2006 03:30:00 6.2 1 8.8 4.2 6.1 1 8.4 4.2 5.1 1.1 8.4 3 303 8 313 165 -0.3 0 -0.3 -0.5 04/02/2006 03:40:00 6 0.9 8 4.2 6 0.9 8 4.2 5.2 1.1 8.8 2.6 306 8 307 165 -0.5 0 -0.3 -0.8 04/02/2006 03:50:00 5.5 0.6 7.2 3.8 5.4 0.6 7.2 3.8 4.8 0.8 6.8 3 308 9 301 165 -0.6 0.1 -0.5 -0.8 04/02/2006 04:00:00 6.9 1.2 9.5 4.2 6.8 1.2 9.1 3.8 6.4 1.1 9.1 3.8 313 8 302 165 -0.6 0 -0.5 -0.8 04/02/2006 04:10:00 6.7 0.8 9.1 4.2 6.6 0.8 9.1 4.2 5.9 1 8 3 310 8 302 165 -0.6 0 -0.5 -0.8 04/02/2006 04:20:00 7.5 1.1 9.9 5.3 7.4 1 9.9 5.3 6.2 1.1 9.1 3.8 307 8 304 165 -0.6 0 -0.5 -0.8 04/02/2006 04:30:00 6.8 1.1 9.5 4.6 6.8 1.2 9.5 4.2 5.7 1.1 8.4 3 304 9 305 165 -0.6 0 -0.5 -0.8 04/02/2006 04:40:00 6.6 1 8.8 4.2 6.6 1 8.8 4.2 5.5 1 8.4 3.4 302 8 290 165 -0.7 0 -0.5 -0.8 04/02/2006 04:50:00 7.4 0.7 9.1 5.7 7.4 0.7 9.1 5.7 5.6 0.8 8.4 4.2 301 5 306 165 -0.5 0 -0.5 -0.8 04/02/2006 05:00:00 7.9 0.8 10.3 5.3 7.9 0.8 9.9 5.3 6.1 0.8 8.4 4.6 302 7 299 165 -0.6 0 -0.5 -0.8 04/02/2006 05:10:00 6.3 0.8 8.8 4.2 6.3 0.8 8.4 4.2 5.1 0.9 7.6 3 293 7 300 165 -0.6 0 -0.5 -0.8 04/02/2006 05:20:00 6.3 0.9 8.4 3.4 6.3 1 8.4 3.8 5.5 1 7.6 2.3 291 7 291 165 -0.5 0 -0.3 -0.8 04/02/2006 05:30:00 5.4 1 8 2.6 5.5 1 8.4 2.6 4.6 1 7.6 2.3 298 14 285 165 -0.6 0 -0.5 -0.8 04/02/2006 05:40:00 5.3 1.1 8 3 5.3 1.1 8.4 3 4.7 1 7.2 2.3 298 12 284 165 -0.5 0 -0.3 -0.8 04/02/2006 05:50:00 5.3 0.9 7.6 3 5.3 0.9 7.2 3 4.7 1 7.2 2.3 308 11 314 165 -0.5 0 -0.5 -0.8 04/02/2006 06:00:00 5.1 0.9 7.2 2.6 5 0.9 7.2 3 4.3 0.8 6.8 2.6 303 10 305 165 -0.6 0 -0.5 -0.8 04/02/2006 06:10:00 5.6 0.9 8 3.4 5.5 0.9 8 3.8 4.8 1 7.6 2.6 302 9 293 165 -0.7 0 -0.5 -0.8 04/02/2006 06:20:00 5.3 1.3 8 1.9 5.3 1.2 8 1.9 4.6 1.2 8 1.9 291 9 297 165 -0.8 0 -0.5 -1 04/02/2006 06:30:00 4.2 0.8 7.2 2.3 4.2 0.9 7.2 1.9 3.6 0.8 6.8 1.9 293 11 290 165 -0.8 0 -0.5 -1 04/02/2006 06:40:00 4.4 0.9 6.8 2.3 4.4 0.9 6.8 2.6 3.9 1 6.1 2.3 298 11 289 165 -0.7 0 -0.5 -0.8 04/02/2006 06:50:00 3.6 1 6.5 1.5 3.8 0.8 6.5 2.3 3.7 0.6 5.7 1.9 284 17 307 165 -0.6 0 -0.5 -0.8 04/02/2006 07:00:00 3.3 1 5.7 0.4 3.6 1 5.7 1.1 3.6 0.9 5.7 1.9 272 13 284 165 -0.7 0 -0.5 -0.8 04/02/2006 07:10:00 4.2 1 7.2 1.9 4.6 0.9 7.6 2.6 4.6 0.8 7.2 3 274 9 279 165 -0.5 0.1 -0.3 -0.8 04/02/2006 07:20:00 5.6 1 8 3.4 5.8 1 8 3.8 5.7 1.1 8.4 3.4 283 6 285 165 -0.3 0 -0.1 -0.5 04/02/2006 07:30:00 6.6 0.5 8 5.3 6.7 0.5 8.4 5.3 6.3 0.7 8 4.2 287 5 287 165 -0.2 0 -0.1 -0.5 04/02/2006 07:40:00 5.5 0.8 7.2 3.4 5.6 0.8 7.2 3.4 5.2 0.9 7.2 3 287 4 295 165 -0.4 0 -0.3 -0.5 04/02/2006 07:50:00 6.8 0.5 8 5.3 6.8 0.5 8 5.3 5.5 0.7 7.6 3.8 296 5 297 165 -0.2 0 0.2 -0.5 04/02/2006 08:00:00 8.3 0.7 10.3 6.8 8.3 0.6 10.3 6.8 6.4 1 9.1 4.6 302 6 300 165 0.2 0.1 0.7 -0.1 04/02/2006 08:10:00 8 0.6 9.5 6.5 7.9 0.6 9.5 6.5 5.9 0.7 8 4.2 303 4 307 165 0.2 0 0.4 -0.1 04/02/2006 08:20:00 8.6 0.6 10.7 7.6 8.6 0.6 10.7 7.6 6.7 1.1 10.3 4.6 295 6 290 165 0.2 0 0.2 0.2 04/02/2006 08:30:00 9.6 0.8 11.8 6.8 9.5 0.8 12.2 6.8 7.8 1.1 11.1 4.9 293 5 292 165 0.4 0 0.7 0.2 04/02/2006 08:40:00 6 2.7 10.3 0.4 6 2.7 10.3 0.4 4.8 2.5 9.9 0.4 288 26 296 165 0.8 0.1 1.4 0.7 04/02/2006 08:50:00 3.6 1.5 7.6 0.4 3.7 1.5 7.2 0.4 3.2 1.2 6.8 0.4 313 112 284 165 1.5 0.1 1.8 1.1 04/02/2006 09:00:00 1.7 1.4 6.5 0.4 1.7 1.5 6.5 0.4 1.9 1.2 5.7 0.4 176 79 307 165 2 0.2 2.3 1.6 04/02/2006 09:10:00 2.6 1.5 4.9 0.4 2.6 1.5 5.7 0.4 3 1.2 5.3 0.4 162 66 165 165 2.4 0.1 2.6 1.8 04/02/2006 09:20:00 4.1 0.8 5.7 1.1 4 0.8 6.1 1.1 4.4 0.8 6.1 1.9 166 7 165 165 1.9 0.1 2.3 1.4 04/02/2006 09:30:00 1.9 1.3 4.2 0.4 1.8 1.3 4.6 0.4 2.2 1.3 4.6 0.4 254 69 167 165 2.2 0.3 2.8 1.6 04/02/2006 09:40:00 2.4 1.3 4.6 0.4 2.4 1.3 4.9 0.4 2.8 1.2 5.3 0.4 234 24 211 165 2.4 0.3 2.8 1.6 04/02/2006 09:50:00 3.1 1 5.7 0.4 3.2 1 5.7 0.4 3.3 0.8 5.3 1.1 245 30 284 165 2.1 0.2 2.6 1.6 04/02/2006 10:00:00 3 0.5 4.6 1.5 2.8 0.6 4.6 1.1 3.1 0.4 4.6 2.3 222 16 224 165 2.4 0.2 2.8 1.8 04/02/2006 10:10:00 2 1.1 4.9 0.4 1.8 1.1 4.6 0.4 2.3 1 4.9 0.4 204 41 230 165 3.3 0.4 3.8 2.3 04/02/2006 10:20:00 1.8 0.7 3 0.4 1.5 0.7 3 0.4 2.1 0.7 4.2 0.4 165 13 145 165 3.2 0 3.5 3 04/02/2006 10:30:00 1 0.6 2.6 0.4 0.6 0.5 2.3 0.4 1.2 0.6 2.6 0.4 209 86 290 165 3.4 0.4 4.5 3 04/02/2006 10:40:00 1.3 0.7 3 0.4 0.9 0.6 3 0.4 1.4 0.6 2.6 0.4 137 29 176 165 4.5 0.1 5 4.3 04/02/2006 10:50:00 2 1 4.2 0.4 1.7 1.1 4.2 0.4 2.2 1 4.6 0.4 129 26 125 165 3.8 0.7 5.5 2.8 04/02/2006 11:00:00 3.2 0.7 5.3 1.5 2.9 0.8 4.9 0.4 3.2 0.7 4.9 1.1 144 14 129 165 3 0 3.3 2.8 04/02/2006 11:10:00 3.9 0.6 5.3 2.6 3.6 0.6 5.3 1.9 3.9 0.5 5.3 2.6 143 13 129 165 2.9 0 3.3 2.8 04/02/2006 11:20:00 4.3 1 6.8 2.3 4 1.1 6.8 1.9 4.3 1 6.5 1.9 141 9 119 165 2.9 0 3.5 2.6 04/02/2006 11:30:00 4.8 0.6 6.5 3.4 4.5 0.6 6.5 3 4.8 0.6 6.8 3.4 149 9 133 165 2.4 0 2.8 2.3 04/02/2006 11:40:00 4 0.5 5.3 2.6 3.7 0.5 4.9 2.3 4 0.5 5.3 2.3 152 9 145 165 2.6 0 2.8 2.3 04/02/2006 11:50:00 3.9 0.9 6.8 2.3 3.5 1 6.5 1.5 3.9 1 6.8 1.9 149 13 171 165 2.9 0.1 3.3 2.6 04/02/2006 12:00:00 3.6 0.8 5.3 1.9 3.1 0.9 4.9 1.1 3.6 0.8 5.7 1.9 169 11 156 165 3.3 0 3.5 2.8 04/02/2006 12:10:00 3.9 1 6.1 1.9 3.4 1.1 6.5 1.1 3.9 1 6.5 1.9 167 9 171 165 3.4 0.1 3.8 3.3 04/02/2006 12:20:00 4.4 0.6 6.5 3 4 0.7 6.1 2.3 4.5 0.6 6.5 3 165 11 165 165 3.5 0 3.8 3.5 04/02/2006 12:30:00 4.5 0.6 5.7 3 4.1 0.7 5.7 2.6 4.6 0.7 6.1 3 170 8 165 165 3.6 0 3.8 3.5 04/02/2006 12:40:00 3.8 0.9 6.1 1.9 3.3 1 5.7 1.1 3.8 0.9 6.5 1.9 172 9 180 165 3.6 0 3.8 3.5 04/02/2006 12:50:00 4.5 0.6 6.8 3 4.1 0.6 6.1 2.6 4.7 0.6 6.5 3 172 9 178 165 3.4 0 4 3 04/02/2006 13:00:00 4.8 0.5 6.1 3.4 4.4 0.5 5.7 3 4.8 0.4 5.7 3.4 163 9 163 165 3 0.1 3.3 2.6 04/02/2006 13:10:00 4.8 0.7 7.2 3 4.4 0.7 6.8 2.3 4.8 0.7 6.8 3 173 9 173 165 3.3 0.1 3.5 3 04/02/2006 13:20:00 4.7 0.6 6.1 3 4.2 0.6 6.1 2.6 4.8 0.7 6.8 3 168 8 172 165 3.4 0 3.5 2.8 04/02/2006 13:30:00 4.8 0.9 6.8 2.6 4.6 0.9 7.2 2.6 4.9 1 7.2 2.6 173 13 173 165 3.2 0.1 3.5 2.6 04/02/2006 13:40:00 4.2 1 6.1 1.9 4 1 6.1 1.5 4.1 0.9 6.1 1.9 205 13 198 165 3.5 0.1 3.8 2.8 04/02/2006 13:50:00 3.7 0.7 5.3 2.3 3.6 0.7 5.3 1.9 3.7 0.8 5.7 1.9 213 9 218 165 3.5 0.2 4 2.8 04/02/2006 14:00:00 4.1 0.6 5.7 2.6 4.1 0.7 6.1 2.6 4.2 0.7 6.1 2.6 213 13 217 165 3.6 0.2 4 3.5 04/02/2006 14:10:00 5.1 0.7 6.5 3 5 0.8 6.5 3 5.1 0.9 7.2 3 200 10 194 165 3.3 0 3.8 2.8 04/02/2006 14:20:00 4.6 1 7.2 2.3 4.5 1 7.2 2.3 4.6 1.1 7.6 2.6 217 14 206 165 3.2 0 3.5 3 04/02/2006 14:30:00 4.9 0.6 6.5 3 5 0.6 6.5 3 5 0.7 7.2 2.6 213 10 207 165 3 0.1 3.3 2.6 04/02/2006 14:40:00 4.4 0.7 6.5 3 4.5 0.8 6.5 2.6 4.5 0.7 6.1 3 210 12 216 165 2.9 0.1 3.3 2.6 04/02/2006 14:50:00 5.6 1.3 9.1 2.6 5.6 1.3 9.1 2.6 5.7 1.2 9.1 3 195 12 214 165 2.9 0 3.3 2.8 04/02/2006 15:00:00 5.9 1 8.4 3.8 6 1 8.8 3.4 6 1.1 9.1 3 207 9 210 165 2.6 0.2 2.8 2.1 04/02/2006 15:10:00 6.3 0.8 8 4.2 6.5 0.8 8.4 4.2 6.4 1 8.4 3.8 217 8 230 165 2.4 0.1 2.8 1.8 04/02/2006 15:20:00 5.1 0.9 7.2 2.6 5.1 0.9 7.2 2.6 5 0.9 7.2 3 215 8 213 165 2.3 0 2.6 1.6 04/02/2006 15:30:00 5.4 0.6 6.8 3.8 5.5 0.7 6.8 3.8 5.5 0.8 7.2 3 207 10 211 165 2 0.1 2.3 1.6 04/02/2006 15:40:00 5 0.8 7.2 3 5 0.8 7.2 3 5.2 0.8 7.2 3.4 201 6 199 165 1.7 0.1 2.1 1.1 04/02/2006 15:50:00 3.9 0.5 5.3 2.6 3.9 0.5 5.3 2.3 4.1 0.5 5.3 3 185 11 195 165 1.6 0 1.8 1.1 04/02/2006 16:00:00 3.4 0.6 5.3 1.9 3.3 0.5 5.3 1.9 3.6 0.5 5.3 2.3 181 10 191 165 1.5 0.1 1.8 0.9 04/02/2006 16:10:00 3.9 0.7 5.7 2.3 3.8 0.7 5.7 2.3 4.1 0.6 5.7 2.6 178 8 176 165 1.4 0.1 1.6 0.9 04/02/2006 16:20:00 3.7 0.4 4.9 2.6 3.6 0.4 4.9 2.6 3.8 0.4 4.9 3 173 6 181 165 1.4 0 1.6 0.9 04/02/2006 16:30:00 3.8 0.4 4.9 3 3.7 0.3 4.6 2.6 4 0.4 4.9 3 162 5 164 165 1.4 0 1.6 1.1 04/02/2006 16:40:00 5.4 0.7 7.2 3.4 5.2 0.7 6.8 3.4 5.5 0.8 6.8 3.4 167 7 166 165 1.6 0 1.8 0.9 04/02/2006 16:50:00 6 0.3 6.8 4.9 5.7 0.3 6.5 4.9 6.2 0.3 6.8 5.3 166 8 164 165 1.4 0.1 1.6 1.4 04/02/2006 17:00:00 6.3 0.4 7.2 5.3 6 0.4 6.8 4.9 6.5 0.5 7.6 5.7 163 6 164 165 1.4 0.1 1.8 0.9 04/02/2006 17:10:00 6.4 0.4 7.2 5.3 6.1 0.4 6.8 4.9 6.5 0.5 7.6 5.3 166 17 164 165 1.2 0 1.4 0.9 04/02/2006 17:20:00 7.5 0.8 9.1 5.3 7.2 0.8 8.8 5.3 7.7 0.8 9.1 5.7 164 6 162 165 1.1 0 1.4 0.7 04/02/2006 17:30:00 7.4 0.6 8.8 5.7 7.3 0.6 8.4 6.1 7.5 0.7 8.8 5.7 163 8 163 165 1.2 0 1.4 0.7 04/02/2006 17:40:00 6.8 0.5 8 5.3 6.5 0.5 8 5.3 7 0.6 8.8 5.3 166 9 164 165 1.1 0 1.4 0.7 04/02/2006 17:50:00 6.4 0.5 7.2 4.9 6.2 0.5 6.8 4.9 6.7 0.5 7.6 4.9 168 4 165 165 1.1 0 1.4 0.9 04/02/2006 18:00:00 5.9 0.4 6.8 4.9 5.7 0.4 6.5 4.9 6 0.5 6.8 4.9 171 4 176 165 1.1 0 1.4 0.7 04/02/2006 18:10:00 6 0.4 6.8 4.9 5.8 0.3 6.5 4.9 6.3 0.4 7.2 4.9 169 4 176 165 1.2 0 1.4 0.9 04/02/2006 18:20:00 6.4 0.5 7.6 4.9 6.2 0.5 7.2 4.9 6.6 0.5 8 4.9 167 8 162 165 1.1 0 1.4 0.9 04/02/2006 18:30:00 7.5 0.5 8.8 6.1 7.3 0.5 8.4 6.1 7.7 0.6 9.1 5.7 168 4 166 165 1.1 0 1.4 0.9 04/02/2006 18:40:00 8.3 0.4 9.1 6.8 7.9 0.4 8.8 6.8 8.5 0.4 9.5 7.2 168 5 168 165 1 0 1.1 0.9 04/02/2006 18:50:00 7.7 0.4 8.8 6.5 7.4 0.4 8.4 6.1 7.8 0.4 9.1 6.5 170 8 169 165 0.9 0 1.1 0.9 04/02/2006 19:00:00 7.5 0.5 8.8 6.5 7.3 0.5 8.4 6.1 7.7 0.5 8.8 6.5 168 11 165 165 1 0 1.1 0.9 04/02/2006 19:10:00 7.9 0.5 9.1 6.5 7.6 0.5 8.8 6.5 8 0.6 9.1 6.5 166 3 165 165 1 0 1.4 0.9 04/02/2006 19:20:00 8.4 0.5 9.9 6.8 8.2 0.5 9.5 6.8 8.6 0.5 9.9 6.8 164 14 165 165 1.1 0 1.4 0.9 04/02/2006 19:30:00 9 0.5 10.3 7.2 8.8 0.5 9.9 7.2 9.1 0.6 10.3 6.8 164 12 162 165 1.1 0 1.4 0.9 04/02/2006 19:40:00 9.8 0.8 11.1 7.2 9.6 0.7 10.7 7.2 10 1 11.5 6.8 166 11 165 165 1.2 0 1.4 1.1 04/02/2006 19:50:00 9.7 0.7 11.1 8 9.5 0.6 10.7 7.6 9.8 0.7 11.5 8.4 166 4 165 165 1.2 0 1.4 1.1 04/02/2006 20:00:00 9.4 0.8 11.1 7.2 9.2 0.7 10.7 6.8 9.6 0.8 11.5 7.2 167 3 164 165 1.3 0 1.4 0.9 04/02/2006 20:10:00 8.7 0.7 10.3 6.8 8.5 0.6 9.9 6.8 8.8 0.7 10.3 6.8 166 13 167 165 1.3 0 1.4 1.1 04/02/2006 20:20:00 8.7 0.5 9.9 7.2 8.5 0.5 9.9 7.2 8.9 0.6 10.3 7.6 166 6 164 165 1.4 0 1.6 1.1 04/02/2006 20:30:00 8.9 0.5 9.9 7.2 8.7 0.5 10.3 6.8 9.1 0.5 10.3 7.6 166 5 165 165 1.4 0 1.6 1.4 04/02/2006 20:40:00 9.2 0.6 10.7 7.2 9 0.5 10.3 7.6 9.4 0.6 10.7 7.2 169 6 165 165 1.4 0 1.6 1.4 04/02/2006 20:50:00 9.3 0.6 10.7 7.2 9.1 0.5 10.3 7.2 9.6 0.7 11.1 7.2 168 6 167 165 1.4 0 1.6 1.4 04/02/2006 21:00:00 9.6 0.6 11.1 7.6 9.4 0.6 10.7 7.6 9.8 0.7 11.5 7.2 167 8 165 165 1.4 0 1.6 1.4 04/02/2006 21:10:00 8.5 1 10.3 6.5 8.4 0.9 9.9 6.5 8.7 1 10.7 6.5 166 4 166 165 1.4 0 1.6 1.4 04/02/2006 21:20:00 9.5 0.7 11.1 7.6 9.3 0.6 11.1 7.2 9.7 0.8 11.1 7.6 167 12 165 165 1.5 0 1.6 1.4 04/02/2006 21:30:00 10.7 0.5 11.8 8.4 10.4 0.5 11.5 8.4 11 0.6 12.2 8.4 166 8 164 165 1.4 0 1.6 1.4 04/02/2006 21:40:00 10.8 0.5 12.6 9.1 10.6 0.5 11.8 9.1 11.1 0.5 12.6 9.1 165 12 164 165 1.4 0 1.6 1.4 04/02/2006 21:50:00 10.8 0.7 12.2 8 10.6 0.7 11.8 8.4 11 0.8 12.6 7.6 163 10 164 165 1.4 0 1.6 1.4 04/02/2006 22:00:00 10.4 0.5 11.8 8.8 10.3 0.5 11.5 8.8 10.6 0.6 11.8 8.8 162 10 161 165 1.4 0 1.6 1.4 04/02/2006 22:10:00 10.4 0.6 12.2 8.4 10.3 0.6 11.8 8.8 10.6 0.6 12.2 9.1 162 6 156 165 1.4 0 1.6 1.4 04/02/2006 22:20:00 11.2 0.6 13 9.5 11.2 0.6 13 9.9 11.5 0.6 13 9.5 164 7 163 165 1.5 0 1.6 1.4 04/02/2006 22:30:00 10.9 0.7 13.3 9.5 10.9 0.7 13.3 9.5 11.2 0.7 13.7 8.8 163 8 160 165 1.5 0 1.6 1.4 04/02/2006 22:40:00 9.9 0.6 11.5 8.4 9.8 0.6 11.1 8.4 10.1 0.6 11.5 8.8 162 9 153 165 1.4 0 1.6 1.4 04/02/2006 22:50:00 9.9 0.5 11.1 8.4 9.8 0.5 11.1 8.4 10.1 0.6 11.8 8 162 9 160 165 1.5 0 1.6 1.4 04/02/2006 23:00:00 10.1 0.6 11.5 8.4 10 0.6 11.1 8.8 10.4 0.6 11.8 8.4 163 4 165 165 1.5 0 1.6 1.4 04/02/2006 23:10:00 10.6 0.5 11.8 9.1 10.5 0.5 11.8 9.1 11 0.5 12.6 9.1 163 12 166 165 1.4 0 1.6 1.4 04/02/2006 23:20:00 10.7 0.6 12.2 9.1 10.7 0.5 12.2 9.5 11 0.6 13 9.5 165 12 181 165 1.5 0 1.6 1.4 04/02/2006 23:30:00 10.4 0.7 12.6 8.8 10.4 0.6 12.2 8.8 10.6 0.6 12.6 9.1 165 3 165 165 1.5 0 1.6 1.4 04/02/2006 23:40:00 10.4 0.8 12.2 8.8 10.4 0.7 12.2 8.8 10.5 0.7 12.2 8.8 166 6 165 165 1.6 0 1.8 1.4 04/02/2006 23:50:00 11 0.6 12.6 9.5 10.9 0.5 12.2 9.1 11.2 0.6 13 9.5 167 10 165 165 1.6 0 1.8 1.4 04/03/2006 00:00:00 10.4 0.5 11.8 8.8 10.4 0.5 11.8 8.8 10.6 0.5 11.8 8.8 164 2 173 165 1.6 0 1.8 1.6 04/03/2006 00:10:00 9.1 0.8 11.1 7.2 9 0.8 10.7 7.2 9.1 0.9 11.5 6.8 162 9 163 165 1.6 0 1.8 1.6 04/03/2006 00:20:00 8.8 0.7 10.7 6.5 8.8 0.6 10.7 6.5 8.9 0.6 10.7 7.2 162 8 158 165 1.6 0 1.8 1.4 04/03/2006 00:30:00 8.4 0.7 10.3 6.8 8.3 0.7 10.3 6.8 8.5 0.7 9.9 6.5 164 1 164 165 1.7 0 1.8 1.4 04/03/2006 00:40:00 8.2 0.8 10.7 6.1 8.1 0.8 10.7 5.7 8.2 0.8 10.7 6.1 164 0 164 165 1.7 0 1.8 1.6 04/03/2006 00:50:00 8.8 0.8 11.5 6.8 8.7 0.8 11.1 7.2 9.1 0.8 11.5 7.2 164 0 164 165 1.7 0 1.8 1.6 04/03/2006 01:00:00 8.8 0.7 10.7 6.5 8.7 0.6 10.3 6.5 8.8 0.7 10.7 6.8 164 0 164 165 1.7 0 1.8 1.6 04/03/2006 01:10:00 9.8 0.5 11.1 8.4 9.6 0.5 10.7 8 9.9 0.5 11.1 8.4 164 0 164 165 1.7 0 1.8 1.6 04/03/2006 01:20:00 9.6 0.6 11.1 8 9.5 0.5 10.7 7.6 9.7 0.6 11.1 7.6 164 0 164 165 1.6 0 1.8 1.6 04/03/2006 01:30:00 8.9 0.8 10.7 6.8 8.9 0.7 10.3 6.8 9.1 0.7 10.7 7.2 164 0 164 165 1.7 0 1.8 1.6 04/03/2006 01:40:00 8.3 0.6 9.9 6.8 8.3 0.6 9.5 6.8 8.5 0.6 9.9 7.2 164 0 164 165 1.7 0 1.8 1.6 04/03/2006 01:50:00 8.5 0.6 10.3 6.8 8.5 0.6 9.9 7.2 8.7 0.6 9.9 7.2 164 0 164 165 1.7 0 1.8 1.6 04/03/2006 02:00:00 7.9 0.5 9.5 6.5 8 0.5 9.1 6.5 8.1 0.4 9.9 7.2 164 0 164 165 1.7 0 1.8 1.6 04/03/2006 02:10:00 7.6 0.4 8.8 6.5 7.6 0.4 8.8 6.8 7.8 0.4 8.8 6.8 164 0 164 165 1.7 0 1.8 1.6 04/03/2006 02:20:00 7.5 0.5 8.8 6.5 7.5 0.4 8.8 6.5 7.7 0.4 8.8 6.5 164 0 164 165 1.7 0 1.8 1.6 04/03/2006 02:30:00 7.2 0.6 8.8 6.1 7.2 0.6 8.8 6.1 7.5 0.5 8.8 6.5 164 0 164 165 1.7 0 1.8 1.6 04/03/2006 02:40:00 7.6 0.6 9.5 6.1 7.7 0.6 9.5 6.1 7.9 0.6 9.1 6.5 164 0 164 165 1.7 0 1.8 1.6 04/03/2006 02:50:00 8.6 0.5 9.5 7.2 8.6 0.4 9.9 7.6 8.7 0.5 9.9 7.2 164 0 164 165 1.7 0 1.8 1.6 04/03/2006 03:00:00 8 0.7 9.5 6.5 8.1 0.6 9.9 6.8 8.3 0.6 9.9 6.5 164 0 164 165 1.7 0 1.8 1.6 04/03/2006 03:10:00 7.1 0.6 8.4 5.7 7.3 0.5 8.4 6.1 7.4 0.6 8.8 6.1 164 0 164 165 1.7 0 1.8 1.6 04/03/2006 03:20:00 6.5 0.4 8 5.7 6.7 0.4 8 5.7 6.8 0.4 8 6.1 164 0 164 165 1.7 0 1.8 1.6 04/03/2006 03:30:00 5.9 0.4 7.2 4.9 6 0.4 7.2 5.3 6.3 0.4 7.2 5.3 164 0 164 165 1.7 0 1.8 1.6 04/03/2006 03:40:00 5.3 0.3 6.5 4.6 5.4 0.3 6.1 4.9 5.8 0.3 6.5 4.9 164 0 164 165 1.7 0 1.8 1.6 04/03/2006 03:50:00 5.1 0.4 6.1 4.2 5.2 0.4 6.1 4.2 5.5 0.4 6.5 4.6 164 0 164 165 1.8 0 1.8 1.6 04/03/2006 04:00:00 5 0.4 6.1 4.2 5.1 0.4 6.1 4.2 5.4 0.4 6.1 4.6 164 0 164 165 1.8 0 1.8 1.6 04/03/2006 04:10:00 4.2 0.4 5.3 3 4.3 0.5 5.3 3 4.7 0.4 5.7 3.8 164 0 164 165 1.7 0 1.8 1.6 04/03/2006 04:20:00 3.5 0.4 4.2 2.6 3.5 0.4 4.6 2.6 4.1 0.3 4.9 3.4 164 0 164 165 1.8 0 1.8 1.6 04/03/2006 04:30:00 2.8 0.4 3.8 1.9 2.7 0.4 3.8 1.9 3.5 0.4 4.6 2.6 164 0 164 165 1.8 0 1.8 1.6 04/03/2006 04:40:00 3.6 0.6 4.6 2.3 3.6 0.5 4.6 2.3 3.9 0.4 4.6 3 164 0 164 165 1.7 0 1.8 1.6 04/03/2006 04:50:00 3.6 0.5 4.6 2.3 3.6 0.5 4.6 2.3 3.9 0.5 4.6 2.6 164 0 164 165 1.7 0 1.8 1.6 04/03/2006 05:00:00 3.8 0.4 4.6 3 3.8 0.3 4.6 3 4 0.4 4.6 3 164 0 164 165 1.7 0 1.8 1.6 04/03/2006 05:10:00 3.2 0.4 4.2 2.6 3.4 0.3 4.2 2.6 3.4 0.3 4.2 2.3 164 0 164 165 1.7 0 1.8 1.6 04/03/2006 05:20:00 2.5 0.6 3.8 1.1 2.6 0.5 3.8 1.1 2.7 0.4 3.8 1.9 164 0 164 165 1.7 0 1.8 1.6 04/03/2006 05:30:00 3.4 0.4 4.2 2.6 3.5 0.4 4.2 2.3 3.3 0.3 4.2 2.3 164 0 164 165 1.7 0 1.8 1.6 04/03/2006 05:40:00 3.9 0.7 5.3 2.3 4 0.6 5.3 2.6 3.9 0.6 5.3 2.6 164 0 164 165 1.7 0 1.8 1.6 04/03/2006 05:50:00 4.2 0.5 4.9 2.6 4.3 0.5 5.3 2.6 4.2 0.4 5.3 3 164 0 164 165 1.8 0 1.8 1.6 04/03/2006 06:00:00 4.4 0.5 5.7 3.4 4.4 0.4 5.7 3.4 4.2 0.4 4.9 3.4 164 0 164 165 1.8 0 1.8 1.6 04/03/2006 06:10:00 4.5 0.3 5.7 3.8 4.6 0.3 5.7 3.8 4.5 0.3 5.3 3.8 164 0 164 165 1.8 0 1.8 1.6 04/03/2006 06:20:00 5.4 0.5 6.5 4.2 5.6 0.6 6.8 4.2 5.3 0.6 6.5 4.2 164 0 164 165 1.8 0 2.1 1.6 04/03/2006 06:30:00 6.6 0.8 8.8 4.2 6.7 0.8 8.8 4.6 6.6 0.8 9.1 4.9 163 4 164 165 2 0 2.3 1.8 04/03/2006 06:40:00 6.8 1 8.8 4.6 6.8 1 9.1 4.6 6.8 1 8.4 4.6 169 14 165 165 2 0 2.3 1.8 04/03/2006 06:50:00 5.8 0.7 8.8 4.2 5.8 0.8 8.8 4.2 6 0.8 7.6 4.2 167 8 176 165 2 0 2.3 1.8 04/03/2006 07:00:00 4.5 0.6 6.5 3 4.3 0.6 6.1 3 4.7 0.5 6.1 3 163 9 189 165 1.9 0 2.1 1.8 04/03/2006 07:10:00 4.4 0.6 5.7 3 4.3 0.6 5.7 2.6 4.8 0.5 6.5 3.8 159 11 172 165 2.1 0 2.3 1.8 04/03/2006 07:20:00 4.3 1 6.1 1.9 4 1 5.7 1.9 4.8 1 6.8 2.6 165 7 167 165 2.3 0 2.6 2.1 04/03/2006 07:30:00 3.2 1 5.3 0.7 3.1 1 4.9 0.4 3.8 0.8 5.7 1.9 164 11 143 165 2.4 0 2.6 2.3 04/03/2006 07:40:00 3.4 0.8 5.7 1.5 3.3 0.8 5.3 1.5 3.8 0.7 5.7 2.3 168 9 177 165 2.4 0 2.6 2.3 04/03/2006 07:50:00 4.9 0.4 6.1 3.8 4.6 0.4 5.7 3.4 5 0.5 6.5 3.4 171 11 172 165 2.6 0 2.8 2.3 04/03/2006 08:00:00 6.7 0.9 9.1 4.9 6.3 0.9 8.8 4.9 6.7 0.9 9.1 4.9 176 6 176 165 2.7 0 2.8 2.6 04/03/2006 08:10:00 6.4 0.8 8.4 4.6 6 0.8 8 4.2 6.5 0.8 8.4 4.9 177 6 184 165 2.8 0 2.8 2.6 04/03/2006 08:20:00 7.3 0.5 8.8 6.1 6.9 0.4 8 5.7 7.4 0.4 8.4 6.5 178 3 179 165 2.9 0 3 2.8 04/03/2006 08:30:00 7.9 0.7 9.9 5.3 7.6 0.7 9.9 4.9 7.9 0.8 10.3 5.7 179 7 188 165 3 0 3.3 2.8 04/03/2006 08:40:00 7.3 0.6 8.8 5.7 7.1 0.6 8.8 5.7 7.6 0.6 9.1 5.7 187 5 190 165 3.2 0 3.3 3 04/03/2006 08:50:00 7.1 0.9 9.5 5.3 6.8 0.8 9.1 4.6 7.3 0.8 9.1 5.3 182 4 183 165 3.2 0 3.3 3 04/03/2006 09:00:00 5.7 1 8.4 3.8 5.4 1 8 3.4 5.8 0.9 8.4 4.2 175 6 167 165 3.2 0 3.3 3 04/03/2006 09:10:00 3.3 0.8 4.9 1.9 3.1 0.7 4.9 1.5 3.4 0.7 5.3 1.9 189 12 179 165 3.2 0 3.3 3 04/03/2006 09:20:00 4.1 1 6.5 2.3 3.9 1 6.1 1.9 4.2 1 6.5 2.3 166 11 167 165 3.2 0 3.5 3.3 04/03/2006 09:30:00 7.4 0.8 8.8 4.6 7.1 0.7 8.4 4.6 7.4 0.8 8.8 4.6 174 4 176 165 3.4 0 3.5 3.3 04/03/2006 09:40:00 7.6 0.5 8.8 6.1 7.2 0.6 8.4 5.3 7.7 0.6 8.8 6.1 169 12 172 165 3.4 0 3.5 3.3 04/03/2006 09:50:00 5.5 0.9 7.2 3.4 5.3 0.8 6.8 3.4 5.6 0.8 7.6 3.8 175 6 170 165 3.4 0 3.5 3.3 04/03/2006 10:00:00 6.6 0.5 7.6 5.3 6.3 0.5 7.2 4.9 6.6 0.6 7.6 4.9 166 4 165 165 3.5 0 3.5 3.3 04/03/2006 10:10:00 6.1 0.9 8.4 3.8 5.9 0.8 8 3.8 6.2 0.7 8.4 4.2 162 12 166 165 3.5 0 3.5 3.3 04/03/2006 10:20:00 6.8 0.8 8.4 4.6 6.6 0.8 8 4.2 6.8 0.8 8.8 4.9 163 6 165 165 3.5 0 3.8 3.3 04/03/2006 10:30:00 5.8 0.9 7.6 3.4 5.7 0.9 7.2 3.4 5.8 1 7.6 3.8 179 9 176 165 3.6 0 3.8 3.5 04/03/2006 10:40:00 6.5 0.6 8 4.6 6.3 0.6 8 4.6 6.5 0.6 8.4 4.9 180 7 182 165 3.6 0 3.8 3.5 04/03/2006 10:50:00 5.5 1.2 8 2.6 5.4 1.2 8 2.6 5.6 1.1 8.4 3 183 7 187 165 3.8 0 4 3.5 04/03/2006 11:00:00 7.8 1 10.7 5.7 7.6 1 10.3 5.7 8 1.1 10.7 5.7 179 5 180 165 4 0 4.3 3.8 04/03/2006 11:10:00 10 0.5 11.5 8.4 9.6 0.5 10.7 8 10.2 0.6 11.5 8.8 177 5 182 165 4 0 4.3 3.8 04/03/2006 11:20:00 9.5 0.6 11.1 8.4 9.2 0.5 10.7 8 9.8 0.5 11.1 8.4 180 4 184 165 3.9 0 4 3.8 04/03/2006 11:30:00 9.2 0.7 10.7 7.2 8.9 0.7 10.7 7.2 9.4 0.7 11.5 7.6 180 5 182 165 3.9 0 4 3.8 04/03/2006 11:40:00 7.4 0.6 9.5 6.1 7.2 0.5 9.1 5.7 7.8 0.6 9.9 6.1 182 6 175 165 3.9 0 4 3.8 04/03/2006 11:50:00 6.4 0.9 8.4 3.8 6.1 0.8 8 3.8 6.6 0.9 8.4 3.8 174 9 165 165 3.9 0 4 3.8 04/03/2006 12:00:00 6.7 0.6 8.4 4.9 6.3 0.6 8 4.6 6.7 0.6 8 5.3 167 6 170 165 4 0 4.3 3.8 04/03/2006 12:10:00 6.2 0.6 7.6 4.6 5.9 0.6 7.2 4.2 6.2 0.6 8 4.9 173 5 172 165 4.1 0 4.5 3.8 04/03/2006 12:20:00 7.4 0.8 9.5 5.7 7 0.7 8.8 4.9 7.3 0.8 9.1 5.3 172 6 177 165 4.2 0 4.5 3.8 04/03/2006 12:30:00 7.2 0.7 8.8 4.9 6.9 0.6 8.4 4.9 7.3 0.6 8.8 5.3 174 5 175 165 4.4 0 4.5 4 04/03/2006 12:40:00 8 0.5 9.5 6.5 7.7 0.5 8.8 6.5 8 0.5 9.5 6.8 174 5 176 165 4.5 0 4.8 4 04/03/2006 12:50:00 10.2 0.9 11.8 7.2 9.6 0.8 11.1 6.5 10.3 0.9 12.2 8 172 5 174 165 4.3 0.1 4.5 3.8 04/03/2006 13:00:00 9.2 0.8 10.7 6.5 8.8 0.8 10.3 6.1 9.2 0.8 10.7 6.8 178 5 179 165 4.3 0 4.5 3.8 04/03/2006 13:10:00 7.9 0.8 9.5 5.7 7.7 0.7 9.1 5.3 8 0.9 10.3 5.7 182 5 186 165 4.6 0.1 4.8 4 04/03/2006 13:20:00 4.8 1.4 8 1.9 4.7 1.4 7.6 1.9 4.8 1.5 8 1.9 191 9 179 165 5 0.1 5.2 4.5 04/03/2006 13:30:00 4.8 1.2 8 2.3 4.6 1.2 7.6 2.3 4.9 1.1 8.8 2.6 184 10 186 165 5 0 5.2 4.5 04/03/2006 13:40:00 6.2 0.8 8.4 4.2 6 0.8 8 4.2 6.2 0.8 8.4 4.2 187 10 190 165 4.9 0 5.2 4.5 04/03/2006 13:50:00 7.2 1.1 9.1 3.4 6.8 1.1 8.8 3.4 7.2 1.1 9.5 4.2 182 7 183 165 5 0.1 5.2 4.5 04/03/2006 14:00:00 9.5 0.6 11.5 7.2 9.1 0.6 11.5 7.2 9.6 0.7 11.1 6.8 176 10 177 165 5.2 0.1 5.5 4.8 04/03/2006 14:10:00 8.3 0.7 9.9 6.5 8 0.7 9.5 6.1 8.5 0.8 9.9 6.5 177 6 174 165 5.4 0 5.7 5 04/03/2006 14:20:00 6.8 0.9 8.8 4.6 6.5 0.9 8.8 4.6 7 1 9.1 4.6 175 6 174 165 6 0.1 6.2 5.5 04/03/2006 14:30:00 3.7 0.8 5.7 2.3 3.5 0.8 5.3 1.9 3.9 0.7 5.7 2.6 168 7 176 165 5.7 0.1 6 5.5 04/03/2006 14:40:00 2.3 0.7 3.4 0.4 2 0.8 3.4 0.4 2.4 0.7 3.8 0.4 157 17 164 165 5.9 0.2 6.5 5.7 04/03/2006 14:50:00 2.4 1.5 4.9 0.4 2.3 1.6 5.3 0.4 2.4 1.5 4.9 0.4 220 28 227 165 6.9 0.3 7.5 6 04/03/2006 15:00:00 4.7 0.7 6.5 3 4.8 0.7 6.5 3 4.8 0.7 6.5 3 216 9 220 165 6.4 0 6.7 6.2 04/03/2006 15:10:00 3.6 0.6 5.7 2.3 3.4 0.6 5.3 1.9 3.7 0.6 4.9 2.3 195 17 211 165 6.7 0 7 6.5 04/03/2006 15:20:00 2.9 0.6 4.9 1.5 2.8 0.6 4.6 1.5 3.1 0.6 4.6 0.7 162 26 196 165 6.8 0 7 6.7 04/03/2006 15:30:00 2.9 0.3 3.8 1.9 2.7 0.4 3.8 1.5 3.1 0.3 3.8 2.3 164 11 165 165 7 0 7.3 6.7 04/03/2006 15:40:00 2.2 0.6 3.4 0.7 2 0.7 3 0.4 2.4 0.5 3.4 1.1 170 12 151 165 6.9 0 7.3 6.7 04/03/2006 15:50:00 2 0.6 3.4 0.7 1.8 0.6 3 0.4 2.2 0.4 3.4 1.1 176 18 195 165 7.1 0 7.5 7 04/03/2006 16:00:00 0.7 0.6 2.6 0.4 0.6 0.6 2.6 0.4 0.9 0.8 3 0.4 201 47 161 165 7.4 0 7.8 7 04/03/2006 16:10:00 0.5 0.4 2.3 0.4 0.4 0.2 1.5 0.4 0.7 0.5 2.3 0.4 131 94 4 165 8.1 0.1 8.5 7.5 04/03/2006 16:20:00 3.4 0.9 4.9 1.5 3.2 1.1 4.9 0.4 3.6 0.9 5.3 1.9 39 22 50 165 7.6 0.6 8.3 6.7 04/03/2006 16:30:00 4.5 0.4 5.3 3 4.3 0.4 5.3 2.6 4.5 0.5 5.7 3 47 5 51 165 6.6 0 6.7 6 04/03/2006 16:40:00 3.8 0.3 4.9 2.6 3.6 0.4 4.6 2.6 3.9 0.4 4.9 2.6 48 4 55 165 6.4 0.2 6.7 6 04/03/2006 16:50:00 3.4 0.3 4.2 2.6 3.3 0.3 4.2 2.6 3.7 0.3 4.6 2.6 36 6 50 165 6.4 0.2 6.7 5.7 04/03/2006 17:00:00 4 0.4 4.9 2.6 4 0.4 4.9 2.6 4.1 0.4 4.9 2.6 42 6 44 165 6.6 0 6.7 6 04/03/2006 17:10:00 3.5 0.3 4.6 2.6 3.5 0.3 4.2 2.6 3.6 0.4 4.9 2.6 42 3 36 165 6.1 0.2 6.7 5.7 04/03/2006 17:20:00 3.7 0.3 4.6 2.6 3.7 0.4 4.6 2.3 3.7 0.5 4.6 2.3 39 4 43 165 6.1 0 6.2 5.5 04/03/2006 17:30:00 3.9 0.3 4.9 3.4 4 0.3 4.9 3.4 4 0.4 4.9 3 35 4 33 165 5.9 0.1 6.2 5.7 04/03/2006 17:40:00 4.3 0.3 4.9 3.4 4.2 0.3 4.9 3.4 4.4 0.3 5.3 3.8 31 3 32 165 5.7 0 6 5.7 04/03/2006 17:50:00 4 0.7 5.3 2.6 3.9 0.7 5.3 2.6 4.1 0.6 5.3 2.6 25 6 26 165 5.7 0.1 5.7 5.5 04/03/2006 18:00:00 2.1 0.4 3 1.1 1.6 0.4 2.6 0.7 2.2 0.4 3 1.1 351 11 17 165 5.6 0.1 5.7 5.2 04/03/2006 18:10:00 0.8 0.4 1.9 0.4 1 0.4 2.3 0.4 1.3 0.3 2.3 0.7 13 29 333 165 5.6 0.2 6 5.2 04/03/2006 18:20:00 0.5 0.2 1.1 0.4 0.6 0.3 1.1 0.4 0.9 0.3 1.5 0.4 14 28 348 165 5.6 0.2 6 5.2 04/03/2006 18:30:00 0.7 0.2 1.1 0.4 0.9 0.3 1.5 0.4 1 0.2 1.5 0.4 336 10 341 165 5.6 0.2 6.2 5.2 04/03/2006 18:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0.2 1.1 0.4 325 0 165 165 5.7 0.1 6 5.2 04/03/2006 18:50:00 0.4 0.1 1.1 0.4 0.4 0.2 1.1 0.4 0.5 0.2 1.5 0.4 336 43 143 165 5.6 0.1 5.7 5.2 04/03/2006 19:00:00 1.3 0.3 1.9 0.4 1.5 0.3 1.9 0.7 1.6 0.3 2.3 0.7 182 8 178 165 5.5 0 5.7 5 04/03/2006 19:10:00 0.4 0.1 0.7 0.4 0.4 0.1 0.7 0.4 0.4 0.2 1.1 0.4 186 0 186 165 5.2 0 5.7 5 04/03/2006 19:20:00 0.9 0.4 1.9 0.4 1.1 0.4 1.9 0.4 1.3 0.4 1.9 0.4 186 0 186 165 5.2 0.1 5.5 4.8 04/03/2006 19:30:00 1 0.5 1.9 0.4 1.2 0.5 2.3 0.4 1.2 0.5 2.3 0.4 218 27 261 165 5 0 5.2 4.5 04/03/2006 19:40:00 2.1 0.3 2.6 1.5 2.2 0.2 3 1.5 2.2 0.3 2.6 1.1 306 17 286 165 5 0 5.2 4.5 04/03/2006 19:50:00 1.9 0.4 3 1.1 2.1 0.4 3.4 1.5 2.1 0.3 3 1.5 331 10 339 165 4.9 0 5 4.3 04/03/2006 20:00:00 2.2 0.6 3.4 1.5 1.7 0.5 3 0.7 2.5 0.6 3.4 1.5 352 9 349 165 4.8 0 5 4.5 04/03/2006 20:10:00 2.7 0.6 3.4 1.5 2.6 0.7 3.8 1.1 2.9 0.4 3.8 1.5 20 6 15 165 4.8 0.1 5 4.3 04/03/2006 20:20:00 1 0.4 1.9 0.4 1 0.4 1.5 0.4 1.5 0.4 2.3 0.7 24 0 24 165 4.9 0 5.2 4.5 04/03/2006 20:30:00 0.9 0.5 2.3 0.4 0.9 0.6 2.3 0.4 1.3 0.6 3 0.4 98 38 87 165 5.1 0.2 5.2 4.5 04/03/2006 20:40:00 0.8 0.4 1.9 0.4 0.8 0.4 1.5 0.4 1.1 0.6 1.9 0.4 135 11 151 165 5 0.1 5.2 4.5 04/03/2006 20:50:00 0.7 0.4 1.9 0.4 0.7 0.4 1.5 0.4 1.2 0.4 2.3 0.4 173 15 165 165 5.1 0 5.2 5 04/03/2006 21:00:00 1.4 0.5 2.6 0.4 1.4 0.6 2.6 0.4 1.8 0.4 2.6 0.7 162 13 172 165 4.9 0 5.5 4.5 04/03/2006 21:10:00 0.9 0.4 1.9 0.4 1 0.3 1.9 0.4 1.5 0.3 2.3 1.1 147 10 154 165 4.7 0 4.8 4.5 04/03/2006 21:20:00 1.4 0.5 2.3 0.4 1.4 0.5 2.3 0.4 1.8 0.3 2.3 1.1 135 3 140 165 4.6 0 4.8 4.3 04/03/2006 21:30:00 1.5 0.5 2.3 0.4 1.4 0.5 1.9 0.4 1.9 0.4 2.3 0.7 156 6 164 165 4.5 0 4.8 4.3 04/03/2006 21:40:00 0.5 0.3 1.5 0.4 0.6 0.4 1.5 0.4 0.7 0.4 1.5 0.4 119 32 84 165 4.6 0 4.8 4.3 04/03/2006 21:50:00 1.4 0.4 2.3 0.4 1.3 0.4 2.3 0.4 1.8 0.4 2.6 1.1 155 8 162 165 4.7 0 5 4.5 04/03/2006 22:00:00 0.8 0.3 1.5 0.4 0.8 0.3 1.5 0.4 1.3 0.2 1.9 0.7 135 11 118 165 4.5 0 4.8 4.3 04/03/2006 22:10:00 1 0.5 1.9 0.4 1.2 0.4 1.9 0.4 1.5 0.2 1.9 1.1 123 3 119 165 4.6 0 4.8 4.3 04/03/2006 22:20:00 1.6 0.3 2.3 0.7 1.7 0.3 2.3 1.1 1.9 0.3 2.6 1.5 126 6 130 165 4.6 0.1 4.8 4.3 04/03/2006 22:30:00 2.4 0.2 2.6 1.9 2.5 0.2 3 1.9 2.6 0.2 3 2.3 103 4 99 165 4.6 0 4.8 4.5 04/03/2006 22:40:00 3.3 0.4 4.2 2.3 3.4 0.4 4.2 2.6 3.5 0.3 4.2 2.6 113 6 118 165 4.6 0 4.8 4.5 04/03/2006 22:50:00 3.1 0.3 3.8 1.9 3.3 0.3 3.8 2.3 3.3 0.3 3.8 2.3 130 4 129 165 4.5 0 4.8 4.5 04/03/2006 23:00:00 2.8 0.3 3.4 1.9 3 0.3 3.4 2.3 3 0.3 3.8 2.3 112 7 123 165 4.6 0 4.8 4.5 04/03/2006 23:10:00 1.5 0.8 3 0.4 1.7 0.9 3 0.4 1.8 0.8 3 0.4 67 30 81 165 4.5 0 4.8 4.3 04/03/2006 23:20:00 0.7 0.5 1.9 0.4 0.7 0.5 1.9 0.4 1.3 0.6 2.6 0.4 41 43 18 165 4.3 0 4.5 4.3 04/03/2006 23:30:00 1 0.8 3 0.4 1 0.8 3 0.4 1.5 0.8 3.4 0.4 140 79 143 165 4.3 0 4.5 4 04/03/2006 23:40:00 2.7 0.4 3.4 1.5 2.6 0.4 3.4 1.5 2.6 0.4 3.8 1.5 157 9 156 165 4.3 0 4.8 4.3 04/03/2006 23:50:00 3.4 0.4 4.2 2.6 3.3 0.4 4.2 2.6 3.3 0.5 4.6 2.3 162 4 164 165 4.3 0 4.5 4.3 04/04/2006 00:00:00 3.2 0.5 4.6 2.3 3.2 0.5 4.6 2.3 3.4 0.5 4.9 2.3 162 4 165 165 4.1 0 4.5 4 04/04/2006 00:10:00 3.8 0.4 4.9 3 3.8 0.4 4.6 3 4.1 0.4 4.9 3 161 7 163 165 4 0 4.3 3.8 04/04/2006 00:20:00 3.9 0.3 4.6 3 3.8 0.3 4.6 3 4 0.3 4.9 3.4 154 5 148 165 3.8 0 4 3.8 04/04/2006 00:30:00 3.4 0.3 4.2 2.6 3.3 0.3 3.8 2.6 3.3 0.3 4.2 2.6 157 5 156 165 3.9 0 4.3 3.8 04/04/2006 00:40:00 3.4 0.3 4.2 2.6 3.3 0.3 3.8 2.6 3.4 0.4 4.2 2.6 167 8 175 165 4.2 0 4.5 4 04/04/2006 00:50:00 3 0.4 3.8 2.3 3 0.4 3.8 2.3 3.1 0.4 4.2 2.3 179 4 169 165 4.5 0 4.8 4.3 04/04/2006 01:00:00 3.8 0.5 4.6 2.6 3.6 0.4 4.6 2.6 3.6 0.4 4.6 2.3 178 4 177 165 4.3 0 4.5 4.3 04/04/2006 01:10:00 1 0.6 3 0.4 1 0.7 2.6 0.4 1.4 0.7 2.6 0.4 250 72 183 165 4.1 0.1 4.5 3.8 04/04/2006 01:20:00 1.3 0.5 2.3 0.4 1.4 0.5 2.6 0.4 1.9 0.5 2.6 0.4 325 23 332 165 4.1 0 4.3 3.8 04/04/2006 01:30:00 1.4 0.9 3 0.4 1.3 0.8 2.6 0.4 1.9 0.8 3.4 0.4 341 20 350 165 4.1 0 4.5 4.3 04/04/2006 01:40:00 0.9 0.7 2.6 0.4 1 0.7 2.6 0.4 1.3 0.7 2.6 0.4 177 94 83 165 4.4 0.2 4.8 4 04/04/2006 01:50:00 0.4 0.2 1.1 0.4 0.4 0.2 1.1 0.4 0.8 0.5 1.9 0.4 65 33 99 165 3.8 0.3 4.3 3.3 04/04/2006 02:00:00 1.2 1 3.4 0.4 0.9 0.8 3 0.4 2 1 3.8 0.4 335 41 4 165 2.9 0 3.3 2.8 04/04/2006 02:10:00 3.6 0.3 4.2 2.6 2.5 0.4 3.4 1.1 4 0.3 4.6 3 358 4 356 165 2.8 0 2.8 2.8 04/04/2006 02:20:00 3.1 0.4 3.8 2.3 2.4 0.3 3 1.5 3.6 0.4 4.2 2.6 9 2 7 165 2.8 0 2.8 2.6 04/04/2006 02:30:00 1.9 0.8 3 0.4 2 0.8 3 0.4 2.1 0.8 3.4 0.7 55 24 31 165 3.6 0.5 4.5 2.8 04/04/2006 02:40:00 1.9 0.6 3 0.4 2 0.6 3.4 0.4 2.2 0.6 3.4 0.7 42 11 28 165 4 0.5 4.5 3 04/04/2006 02:50:00 1.3 1 3.4 0.4 1.3 1 3.4 0.4 1.5 0.8 3 0.4 132 27 105 165 3 0.4 4 2.6 04/04/2006 03:00:00 0.4 0.1 0.7 0.4 0.4 0.1 1.1 0.4 0.6 0.3 1.5 0.4 133 11 138 165 3.6 0.4 4.3 2.8 04/04/2006 03:10:00 0.4 0.1 1.1 0.4 0.4 0 0.7 0.4 0.8 0.5 1.9 0.4 84 26 68 165 3 0.2 3.5 2.6 04/04/2006 03:20:00 0.4 0.1 1.1 0.4 0.5 0.2 1.1 0.4 0.8 0.5 1.9 0.4 96 11 88 165 2.8 0.2 3.3 2.3 04/04/2006 03:30:00 0.4 0.1 1.1 0.4 0.4 0 0.4 0.4 0.7 0.4 1.9 0.4 117 26 165 165 3 0.3 3.8 2.6 04/04/2006 03:40:00 0.9 0.3 1.5 0.4 0.8 0.3 1.5 0.4 1.4 0.2 1.9 0.7 167 4 170 165 3.8 0 4 3.5 04/04/2006 03:50:00 0.8 0.3 1.5 0.4 0.9 0.4 1.5 0.4 1.3 0.4 1.9 0.4 163 1 162 165 3.8 0 4 3.5 04/04/2006 04:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.5 0.3 1.1 0.4 165 0 165 165 3.8 0 4 3.5 04/04/2006 04:10:00 0.4 0.1 1.1 0.4 0.4 0.1 1.1 0.4 0.6 0.4 1.9 0.4 164 2 153 165 3.8 0 3.8 3.5 04/04/2006 04:20:00 1.3 0.4 1.9 0.4 1.3 0.4 2.3 0.4 1.6 0.3 2.3 0.7 153 6 148 165 3.3 0.3 3.8 2.8 04/04/2006 04:30:00 0.4 0 0.7 0.4 0.4 0 0.4 0.4 0.5 0.2 1.1 0.4 149 7 142 165 2.9 0 2.8 2.8 04/04/2006 04:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 147 0 165 165 2.8 0 2.8 2.6 04/04/2006 04:50:00 0.8 0.4 1.9 0.4 0.5 0.2 1.1 0.4 1.1 0.6 2.3 0.4 62 61 1 165 2.9 0 3 2.8 04/04/2006 05:00:00 1.8 0.4 2.6 1.1 1 0.6 2.6 0.4 2.2 0.4 3 1.5 3 6 16 165 2.4 0.3 2.8 1.8 04/04/2006 05:10:00 1 0.6 2.6 0.4 0.9 0.6 2.6 0.4 1.5 0.6 2.6 0.4 0 23 21 165 2.2 0.2 2.6 1.8 04/04/2006 05:20:00 0.4 0 0.7 0.4 0.4 0.1 0.7 0.4 0.4 0.2 1.1 0.4 298 6 310 165 2.8 0 2.8 2.6 04/04/2006 05:30:00 1.1 0.6 2.3 0.4 1.2 0.6 2.3 0.4 1.5 0.6 2.3 0.4 183 51 142 165 2.9 0 3 2.8 04/04/2006 05:40:00 0.8 0.5 2.3 0.4 0.9 0.5 2.3 0.4 1.5 0.4 2.3 0.4 173 6 170 165 2.9 0 3 2.8 04/04/2006 05:50:00 0.5 0.3 1.9 0.4 0.5 0.3 1.9 0.4 1 0.4 1.9 0.4 185 17 222 165 2.9 0 3 2.8 04/04/2006 06:00:00 1.8 1.3 3.8 0.4 1.9 1.3 3.8 0.4 1.9 1.2 4.2 0.4 264 30 281 165 2.9 0 3 2.6 04/04/2006 06:10:00 2.9 0.6 4.2 0.4 2.9 0.5 3.8 0.7 2.3 0.5 3.8 1.1 290 7 294 165 2.7 0 2.8 2.6 04/04/2006 06:20:00 2.6 0.4 3.4 1.9 2.6 0.4 3.4 1.9 2.5 0.3 3 1.5 310 12 288 165 2.7 0 2.8 2.3 04/04/2006 06:30:00 2.7 0.5 3.8 1.9 2.7 0.5 3.8 1.5 3 0.5 3.8 1.9 334 5 330 165 2.6 0 2.8 2.6 04/04/2006 06:40:00 3.1 0.5 4.6 1.9 2.4 0.6 3.8 0.7 3.3 0.4 4.2 2.3 351 5 352 165 2.5 0 2.8 2.3 04/04/2006 06:50:00 1 0.7 3 0.4 0.7 0.4 1.5 0.4 1.6 0.5 3 0.4 31 23 2 165 2.7 0 2.8 2.6 04/04/2006 07:00:00 0.5 0.4 1.9 0.4 0.5 0.3 1.9 0.4 0.9 0.6 2.3 0.4 346 28 25 165 2.9 0 3 2.8 04/04/2006 07:10:00 0.4 0.2 1.1 0.4 0.5 0.3 1.5 0.4 0.9 0.4 1.5 0.4 290 12 304 165 2.9 0 3 2.8 04/04/2006 07:20:00 0.4 0.1 0.7 0.4 0.4 0 0.7 0.4 0.7 0.4 1.9 0.4 250 10 261 165 2.8 0 2.8 2.6 04/04/2006 07:30:00 0.5 0.3 1.9 0.4 0.6 0.4 1.9 0.4 1 0.5 2.3 0.4 244 19 268 165 2.8 0 2.8 2.6 04/04/2006 07:40:00 0.5 0.4 1.9 0.4 0.7 0.5 1.9 0.4 0.9 0.5 2.3 0.4 262 6 268 165 2.9 0 3 2.6 04/04/2006 07:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0.1 1.1 0.4 341 51 165 165 2.9 0 3 2.8 04/04/2006 08:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.5 0.2 1.1 0.4 310 15 165 165 2.9 0 3 2.8 04/04/2006 08:10:00 0.8 0.5 1.9 0.4 0.9 0.5 2.3 0.4 1.2 0.5 2.3 0.4 254 17 243 165 2.9 0 3 2.6 04/04/2006 08:20:00 1.1 0.5 2.3 0.4 1.4 0.4 2.6 0.4 1.6 0.4 2.6 0.4 276 5 274 165 2.9 0 3 2.8 04/04/2006 08:30:00 2 0.4 2.6 1.1 2.2 0.4 3 1.1 2.4 0.4 3 1.5 277 4 275 165 2.9 0 3 2.8 04/04/2006 08:40:00 1.6 0.4 2.6 0.7 2.2 0.3 3 1.5 2.3 0.3 3 1.1 270 6 276 165 2.9 0 3 2.8 04/04/2006 08:50:00 1.7 0.5 2.6 0.4 1.9 0.5 3 0.7 1.9 0.4 2.6 1.1 289 6 282 165 3 0 3.3 2.8 04/04/2006 09:00:00 2.2 0.4 3.4 1.5 2.4 0.4 3.4 1.5 2.1 0.4 3 1.1 291 5 298 165 3.2 0 3.3 3 04/04/2006 09:10:00 2.7 0.5 3.8 1.5 2.9 0.4 3.8 1.9 2.3 0.4 3.4 1.5 299 4 296 165 3.1 0 3.3 3 04/04/2006 09:20:00 2.1 0.3 3 1.5 2.4 0.2 3 1.9 1.9 0.3 2.6 1.1 297 6 309 165 3.2 0 3.5 3 04/04/2006 09:30:00 2.8 0.4 3.4 1.9 2.9 0.3 3.8 1.9 2.8 0.5 3.8 1.5 318 7 313 165 3.4 0 3.5 3.3 04/04/2006 09:40:00 2.2 0.6 3.4 1.1 2.2 0.5 3.8 1.1 2.2 0.6 3.8 0.7 323 8 327 165 3.6 0.1 3.8 3.3 04/04/2006 09:50:00 1.6 0.4 2.3 0.4 1.7 0.4 2.3 0.4 1.8 0.3 2.6 0.7 331 5 327 165 3.9 0 4.3 3.5 04/04/2006 10:00:00 1 0.4 1.9 0.4 0.6 0.3 1.5 0.4 1.5 0.4 2.3 0.4 2 10 356 165 4.3 0 4.5 3.8 04/04/2006 10:10:00 1.1 0.4 1.9 0.4 0.8 0.4 1.9 0.4 1.5 0.3 2.3 0.7 19 13 34 165 4.3 0.1 4.5 3.8 04/04/2006 10:20:00 1 0.4 2.3 0.4 0.5 0.2 1.5 0.4 1.6 0.3 2.6 0.7 0 5 355 165 4.4 0 4.5 3.8 04/04/2006 10:30:00 1.3 0.5 2.3 0.4 1 0.5 2.3 0.4 1.6 0.4 2.3 0.4 12 6 28 165 4.7 0.1 5 4.3 04/04/2006 10:40:00 1.1 0.5 2.3 0.4 0.8 0.5 1.9 0.4 1.6 0.4 2.3 0.7 12 10 352 165 4.9 0.2 5.5 4.5 04/04/2006 10:50:00 0.8 0.4 1.9 0.4 0.5 0.3 1.5 0.4 1.2 0.4 2.3 0.4 1 11 12 165 5.5 0.1 5.7 5 04/04/2006 11:00:00 0.9 0.4 1.9 0.4 0.7 0.4 1.9 0.4 1.4 0.4 2.3 0.4 356 7 345 165 5.3 0.2 5.7 4.8 04/04/2006 11:10:00 1 0.4 1.9 0.4 0.8 0.4 1.9 0.4 1.4 0.4 2.3 0.4 15 13 1 165 5.3 0.2 5.7 4.8 04/04/2006 11:20:00 0.4 0.2 1.5 0.4 0.4 0.1 1.1 0.4 0.6 0.4 1.9 0.4 16 18 9 165 5.2 0.1 5.7 5 04/04/2006 11:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.7 0.4 28 2 165 165 4.8 0.2 5.2 4.8 04/04/2006 11:40:00 0.4 0.1 1.1 0.4 0.4 0 0.7 0.4 0.4 0 0.7 0.4 30 5 46 165 4.9 0.1 5.2 4.8 04/04/2006 11:50:00 1.4 0.8 2.6 0.4 1.1 0.6 2.6 0.4 1.5 0.8 2.6 0.4 344 33 5 165 5.3 0 5.7 5 04/04/2006 12:00:00 0.5 0.3 1.5 0.4 0.5 0.2 1.5 0.4 0.7 0.4 1.9 0.4 307 21 336 165 5.2 0 5.2 5 04/04/2006 12:10:00 0.8 0.6 2.6 0.4 0.8 0.6 2.3 0.4 1.1 0.7 2.6 0.4 334 27 339 165 5.4 0.1 5.7 4.8 04/04/2006 12:20:00 1.3 0.6 3 0.4 1.2 0.6 2.6 0.4 1.7 0.5 3 0.7 2 21 21 165 5.6 0 5.7 5 04/04/2006 12:30:00 3.1 0.6 4.2 1.1 3.1 0.6 4.2 0.7 3.4 0.6 4.6 1.5 33 5 32 165 4.6 0.4 5.7 3.8 04/04/2006 12:40:00 3 0.4 3.8 1.9 2.6 0.5 3.8 1.1 3.2 0.4 4.2 1.9 19 6 18 165 4.6 0.1 5 4.3 04/04/2006 12:50:00 3.1 0.5 3.8 1.9 2.5 0.5 3.8 1.5 3.3 0.5 4.2 1.9 19 9 12 165 4.9 0 5 4.5 04/04/2006 13:00:00 2.8 0.4 3.8 1.9 2.8 0.4 3.8 1.5 3 0.4 3.8 1.5 32 8 33 165 4.6 0 4.8 4.3 04/04/2006 13:10:00 2.8 0.3 3.8 1.9 2.6 0.4 3.4 1.1 3 0.3 3.8 1.9 20 6 13 165 4.6 0.1 4.8 4.3 04/04/2006 13:20:00 2.5 0.5 3.8 1.1 1.8 0.5 3.4 0.7 2.7 0.4 3.8 1.5 6 5 14 165 4.9 0 5 4.5 04/04/2006 13:30:00 3.2 0.5 4.2 1.9 3 0.7 4.2 1.1 3.5 0.5 4.6 2.3 15 7 19 165 4.9 0.1 5 4.3 04/04/2006 13:40:00 4.2 0.4 5.3 3 3.9 0.5 4.9 1.9 4.2 0.4 4.9 2.6 15 6 4 165 4.6 0.2 4.8 4.3 04/04/2006 13:50:00 5.2 0.5 6.8 3.8 5.1 0.5 6.5 3.4 5.2 0.5 6.5 3.4 22 6 6 165 4.3 0.2 4.8 3.8 04/04/2006 14:00:00 5.9 0.7 7.2 4.2 5.8 0.8 7.2 3.8 5.9 0.8 7.2 4.2 21 5 25 165 4 0 4.8 3.8 04/04/2006 14:10:00 7.1 0.4 8 5.7 6.9 0.5 8 5.3 7 0.6 8 5.7 19 3 20 165 3.8 0 4 3.5 04/04/2006 14:20:00 6.6 0.4 7.2 4.9 6.2 0.5 7.2 4.9 6.6 0.6 7.6 4.9 16 3 14 165 3.8 0 4 3.5 04/04/2006 14:30:00 7 0.3 8 6.1 6.3 0.5 7.6 4.2 7.1 0.4 8 5.7 10 2 359 165 3.9 0 4 3.5 04/04/2006 14:40:00 7.1 0.4 8 6.1 6.1 0.9 8 3.4 7.2 0.5 8.4 6.1 8 4 16 165 4 0 4.3 3.5 04/04/2006 14:50:00 6.8 0.6 8 5.3 5.3 1.1 7.6 3 6.8 0.7 8.4 4.9 6 4 10 165 4 0 4.3 3.5 04/04/2006 15:00:00 7.2 0.4 8.4 6.1 5.5 1.1 7.6 3.4 7.3 0.5 8.4 6.1 6 5 5 165 4 0 4.3 3.5 04/04/2006 15:10:00 7.4 0.7 8.8 5.7 5.8 1.3 8 2.6 7.5 0.7 8.8 5.7 6 4 10 165 4 0 4.3 3.5 04/04/2006 15:20:00 8.4 0.5 9.5 6.5 6.9 1.1 8.8 3.8 8.4 0.6 9.5 6.8 8 3 9 165 4 0 4.3 3.5 04/04/2006 15:30:00 8.7 0.4 9.5 7.2 7.3 1 8.8 4.2 8.9 0.4 9.9 7.6 9 3 10 165 4 0 4 3.5 04/04/2006 15:40:00 8.7 0.5 9.5 7.2 6.1 1 9.1 3.4 8.8 0.5 9.9 7.2 6 3 353 165 3.8 0 4 3.5 04/04/2006 15:50:00 8.6 0.4 9.5 7.2 6.7 0.9 8.4 4.2 8.7 0.5 9.9 7.2 7 2 9 165 3.8 0 4 3.5 04/04/2006 16:00:00 8.3 0.4 9.1 6.8 7 0.8 8.8 4.6 8.4 0.5 9.5 6.8 9 3 8 165 3.8 0 4.5 3.5 04/04/2006 16:10:00 7.4 0.4 8.8 6.5 5.9 1 8.4 3 7.8 0.4 8.8 6.5 8 3 10 165 3.8 0 4 3.5 04/04/2006 16:20:00 7.6 0.3 8.4 7.2 5.9 0.8 8 3.8 7.9 0.4 9.1 6.5 7 2 11 165 3.8 0 4 3.5 04/04/2006 16:30:00 8 0.6 9.5 6.5 5.1 0.8 7.6 3.8 8.2 0.6 9.9 6.8 2 4 6 165 4 0 4.3 3.5 04/04/2006 16:40:00 8.6 0.8 10.7 5.7 6.2 1.2 9.1 3.4 8.7 0.8 10.7 5.7 4 6 6 165 4 0 4.3 3.5 04/04/2006 16:50:00 8.4 0.6 9.9 6.8 7.3 1 9.1 4.2 8.4 0.7 9.9 6.1 11 5 16 165 4 0 4.3 3.8 04/04/2006 17:00:00 9.4 0.9 11.1 6.5 8.9 1 11.1 5.7 9 1 11.1 6.5 17 5 16 165 4 0 4.3 3.8 04/04/2006 17:10:00 9.7 1.2 12.6 6.5 9.2 1.3 12.2 5.7 9.4 1.3 12.6 6.1 18 6 23 165 3.8 0 4 3.8 04/04/2006 17:20:00 10.1 1.3 13 6.8 9.5 1.6 13 5.3 9.7 1.5 13 6.1 17 7 20 165 3.7 0 3.8 3.5 04/04/2006 17:30:00 10 0.8 11.8 7.6 9.4 1.1 11.8 6.1 9.7 1 11.8 7.6 17 7 20 165 3.6 0 3.8 3.5 04/04/2006 17:40:00 9.1 0.9 11.1 6.5 7.9 1.3 10.7 3.8 8.9 1 11.8 6.5 11 7 5 165 3.6 0 3.8 3.5 04/04/2006 17:50:00 9.4 0.9 11.8 6.5 8 1.1 10.7 4.9 9.3 1 11.8 6.8 11 6 9 165 3.6 0 3.8 3.5 04/04/2006 18:00:00 9 1.1 11.8 6.5 7.9 1.4 11.5 4.9 8.8 1.1 11.8 6.1 12 6 20 165 3.6 0 3.8 3.5 04/04/2006 18:10:00 9.5 1.2 12.2 6.1 8.3 1.7 12.2 4.6 9.3 1.3 12.6 6.5 12 7 22 165 3.5 0 3.5 3.5 04/04/2006 18:20:00 9.5 1.3 13.3 5.7 7.6 1.7 11.1 3.4 9.2 1.2 11.8 5.7 8 6 10 165 3.5 0 3.5 3.5 04/04/2006 18:30:00 9 1 11.1 6.5 7.6 1.2 10.3 3.8 8.8 1 11.1 6.1 10 7 22 165 3.4 0 3.5 3.3 04/04/2006 18:40:00 9.2 1.1 11.8 6.1 8.1 1.5 11.8 4.6 8.9 1.2 12.2 5.7 13 7 25 165 3.3 0 3.5 3.3 04/04/2006 18:50:00 9.3 1.5 13.3 6.1 8.1 1.8 13.3 4.2 8.9 1.3 13 6.5 11 7 21 165 3.2 0 3.5 3.3 04/04/2006 19:00:00 9.9 1.3 13 6.5 8.1 1.3 11.5 4.9 9.8 1.2 13 7.2 9 6 3 165 3.2 0 3.3 3 04/04/2006 19:10:00 10 1 12.2 7.6 7.7 1.2 11.5 4.9 9.9 1 12.2 7.2 7 6 354 165 3.1 0 3.3 3 04/04/2006 19:20:00 9.5 0.8 11.8 7.2 7.8 1 10.3 4.9 9.3 0.8 11.5 7.2 10 6 2 165 3.1 0 3.3 3 04/04/2006 19:30:00 9.6 1.2 13 6.8 8.1 1.4 11.5 4.9 9.3 1.2 12.6 6.1 10 7 12 165 3 0 3.3 3 04/04/2006 19:40:00 10.5 1.1 13.7 7.6 8.5 1.7 13.7 5.3 10.1 1.3 13 7.2 9 7 18 165 3 0 3.3 2.8 04/04/2006 19:50:00 10.9 1.6 14.5 7.6 8.9 2 13.7 4.9 10.6 1.6 14.5 7.2 10 6 8 165 3 0 3 2.8 04/04/2006 20:00:00 9.5 1.2 13 6.5 7.3 1.3 11.1 4.2 9.2 1.1 12.2 6.5 6 7 6 165 3 0 3.3 2.8 04/04/2006 20:10:00 9.6 1.1 11.5 6.8 8 1.6 11.1 4.2 9.3 1.1 11.5 6.8 10 6 7 165 2.9 0 3 2.8 04/04/2006 20:20:00 9.7 1.3 12.6 6.8 7.4 1.7 11.5 3.8 9.6 1.3 12.6 6.5 7 6 12 165 2.9 0 3 2.8 04/04/2006 20:30:00 9.5 0.9 12.2 7.6 7.3 1.5 10.7 4.2 9.4 1 12.2 7.2 8 6 356 165 2.8 0 2.8 2.8 04/04/2006 20:40:00 9.2 1 11.8 5.7 6.8 1.3 10.3 3.4 9.1 1.1 11.8 6.5 5 7 4 165 2.7 0 2.8 2.6 04/04/2006 20:50:00 9.2 1.2 12.6 6.1 6.8 1.7 11.8 3.8 9 1.1 12.2 6.1 6 8 7 165 2.7 0 2.8 2.6 04/04/2006 21:00:00 9.8 1.2 13.3 6.5 7.2 1.5 11.8 3.4 9.5 1.1 12.6 6.8 4 7 17 165 2.7 0 2.8 2.6 04/04/2006 21:10:00 8.6 0.8 11.1 6.8 6.1 1 8.8 4.2 8.4 0.9 11.1 6.1 2 6 0 165 2.7 0 2.8 2.6 04/04/2006 21:20:00 7.7 1.7 13.3 4.9 6.7 1.3 10.7 3.4 7.4 1.7 13.7 4.6 345 13 1 165 2.6 0 2.8 2.6 04/04/2006 21:30:00 9.6 1.1 13.3 6.1 8.1 1.7 12.6 3.8 9.1 1.2 12.6 6.1 352 7 349 165 2.7 0 2.8 2.6 04/04/2006 21:40:00 8.5 1.4 12.6 5.3 7.4 1.8 13.3 3 8.1 1.3 12.6 5.7 351 7 349 165 2.7 0 2.8 2.6 04/04/2006 21:50:00 7.9 1.6 11.8 4.9 6 2 12.2 2.6 7.7 1.5 11.5 4.9 1 8 348 165 2.7 0 2.8 2.6 04/04/2006 22:00:00 10 1.6 14.1 5.7 8.3 1.7 13 4.2 9.7 1.5 13.7 5.3 353 8 359 165 2.7 0 2.8 2.6 04/04/2006 22:10:00 10.9 1.6 14.1 7.2 8.2 1.7 12.2 4.6 10.6 1.7 14.1 7.2 355 6 359 165 2.8 0 3 2.8 04/04/2006 22:20:00 9.3 1.2 13.3 6.5 7.9 1.6 11.8 4.2 8.9 1.3 13.3 6.1 354 10 0 165 2.7 0 2.8 2.6 04/04/2006 22:30:00 9.4 1.2 12.2 6.1 8.3 1.7 11.8 4.2 9.2 1.3 12.6 6.1 350 9 354 165 2.7 0 2.8 2.6 04/04/2006 22:40:00 8.7 1.1 11.8 5.3 7.7 1.5 11.1 3.8 8.5 1.1 12.2 4.9 351 10 356 165 2.7 0 2.8 2.6 04/04/2006 22:50:00 8.7 1.5 11.8 4.6 7.5 1.5 11.1 4.6 8.7 1.5 13 4.9 350 14 0 165 2.7 0 2.8 2.6 04/04/2006 23:00:00 9.3 1.3 12.2 5.7 8.4 1.4 11.8 3.4 8.9 1.5 12.6 5.7 349 8 353 165 2.7 0 2.8 2.6 04/04/2006 23:10:00 9 1.1 13 6.5 7.7 1.5 11.8 4.2 8.7 1.2 12.6 5.7 351 9 9 165 2.6 0 2.8 2.6 04/04/2006 23:20:00 9.5 1 13.3 6.8 8.9 1.4 13.7 4.9 9.3 1 13.3 7.2 348 8 344 165 2.6 0 2.8 2.6 04/04/2006 23:30:00 8.6 1.1 11.1 6.5 7.4 1.6 11.8 3.4 8.5 1.2 11.5 6.1 352 9 359 165 2.7 0 2.8 2.6 04/04/2006 23:40:00 8.5 1.1 12.2 6.1 6.5 1.7 12.2 3.8 8.6 1.1 12.2 5.3 358 9 358 165 2.7 0 2.8 2.6 04/04/2006 23:50:00 8.6 1 11.5 4.9 6.3 1.3 10.3 3.4 8.5 1.2 11.8 4.2 359 9 356 165 2.7 0 2.8 2.6 04/05/2006 00:00:00 9.3 1.2 13 6.5 7.9 1.8 13.7 4.2 9.3 1.3 13.7 6.1 353 11 343 165 2.7 0 2.8 2.6 04/05/2006 00:10:00 7.3 0.9 9.9 4.9 5.9 1.5 9.5 2.6 7.3 0.9 9.9 4.9 355 11 349 165 2.7 0 2.8 2.6 04/05/2006 00:20:00 6.6 0.8 8.8 4.6 5.7 1.5 8.8 2.3 6.6 0.7 8.8 4.9 346 13 324 165 2.7 0 2.8 2.6 04/05/2006 00:30:00 7.2 1 10.3 4.9 7.1 1.1 10.3 4.6 7.2 1 10.3 4.9 338 10 340 165 2.8 0 3 2.6 04/05/2006 00:40:00 8.3 1.7 13.3 4.9 8.3 1.7 13.3 4.9 8.3 1.6 13 4.9 331 9 332 165 2.9 0 3 2.8 04/05/2006 00:50:00 10.6 1.2 14.1 7.6 10.5 1.2 13.7 7.6 10.3 1.3 14.1 6.8 335 7 329 165 3 0 3.3 2.8 04/05/2006 01:00:00 7.7 1.2 11.1 4.9 7 1.7 10.7 3.4 7.5 1.2 10.3 4.6 348 11 345 165 2.9 0 3 2.8 04/05/2006 01:10:00 8.7 1.6 12.6 5.7 8.4 2 12.2 3.8 8.5 1.7 13.3 5.3 334 12 335 165 3 0.1 3.3 2.8 04/05/2006 01:20:00 10.5 1.8 14.9 6.5 10.4 1.9 14.9 5.3 10.3 1.7 14.5 6.5 333 11 332 165 3.2 0 3.5 3 04/05/2006 01:30:00 11.4 1.6 16.1 7.2 11.2 1.6 16.1 7.2 11.1 1.7 15.3 7.6 333 11 340 165 3.3 0 3.5 3 04/05/2006 01:40:00 10.5 1.2 13.7 7.6 10.4 1.1 13.7 7.2 10.1 1.3 13.7 6.8 326 11 306 165 3.1 0.1 3.5 3 04/05/2006 01:50:00 11.6 1.9 17.2 7.2 11.4 1.9 16.8 6.8 11.6 2.1 17.9 6.1 331 11 323 165 3.3 0.1 3.8 2.8 04/05/2006 02:00:00 11.1 1.7 15.3 7.2 11 1.8 15.3 6.8 11 1.8 15.3 4.6 333 11 346 165 3.6 0.1 3.8 3.3 04/05/2006 02:10:00 10.3 1.7 14.5 6.8 9.8 1.7 14.5 6.1 10 1.7 14.1 6.1 340 11 336 165 3.5 0 3.8 3.3 04/05/2006 02:20:00 9.8 1.2 13.3 5.7 9.6 1.4 13.7 4.9 9.4 1.1 13 6.1 338 10 329 165 3.6 0 3.8 3.5 04/05/2006 02:30:00 8.1 1.3 11.1 4.2 8 1.3 10.7 4.2 7.7 1.2 10.3 4.9 327 9 313 165 3.5 0 3.8 3.3 04/05/2006 02:40:00 7.7 0.9 9.9 5.3 7.4 1.1 9.9 4.2 7.4 1 9.9 4.2 334 12 335 165 3.3 0 3.5 3.3 04/05/2006 02:50:00 8 1.5 12.6 5.3 7.8 1.6 12.6 4.2 7.7 1.4 11.5 4.9 336 15 327 165 3.5 0.1 3.8 3.3 04/05/2006 03:00:00 9.5 1.7 13.3 6.5 9.3 1.6 13.3 6.1 8.8 1.4 12.2 5.7 319 10 312 165 3.3 0 3.5 3.3 04/05/2006 03:10:00 10.4 1.2 15.3 7.6 10.3 1.3 14.9 7.2 9.4 1.2 13 6.5 314 8 294 165 3.3 0 3.5 3 04/05/2006 03:20:00 12.9 1.5 16.1 8.8 12.7 1.5 15.6 8.8 10.8 1.6 15.3 6.8 309 9 307 165 3.5 0.1 3.8 3.3 04/05/2006 03:30:00 13.9 1.5 18.3 9.9 13.8 1.5 17.9 9.9 11.9 1.7 16.8 8 310 6 302 165 3.6 0.1 3.8 3.5 04/05/2006 03:40:00 12.6 1.2 16.4 9.5 12.5 1.2 16.1 9.9 10.5 1.6 15.3 7.2 308 7 301 165 3.6 0 3.8 3.5 04/05/2006 03:50:00 13.1 1.5 16.4 8.4 13.1 1.5 16.4 8.8 11.1 1.4 14.9 7.6 309 7 305 165 3.6 0.1 3.8 3.5 04/05/2006 04:00:00 15.5 1.3 18.3 12.2 15.4 1.3 18.7 12.2 13.9 1.6 17.9 9.5 312 6 310 165 3.5 0 3.8 3.3 04/05/2006 04:10:00 14.6 1 17.6 11.8 14.4 1 17.6 11.8 13 1.2 16.8 8.8 312 5 316 165 3.5 0 3.5 3.3 04/05/2006 04:20:00 14.8 1 17.6 11.8 14.7 1.1 17.2 11.8 13.9 1.1 17.2 10.7 315 5 312 165 3.5 0 3.8 3.3 04/05/2006 04:30:00 14.8 1.4 19.1 11.1 14.6 1.4 19.1 11.1 13.1 1.5 16.8 9.1 312 6 307 165 3.5 0 3.5 3.3 04/05/2006 04:40:00 14.9 1.5 18.7 10.7 14.7 1.5 18.7 9.9 13.2 1.7 17.6 9.1 311 6 311 165 3.5 0 3.5 3.3 04/05/2006 04:50:00 14.8 1.3 18.7 11.1 14.7 1.3 18.3 11.1 12.9 1.5 17.6 9.1 310 6 319 165 3.5 0 3.5 3.3 04/05/2006 05:00:00 14.9 1.3 17.9 11.1 14.9 1.3 17.9 11.5 12.6 1.4 16.1 9.1 309 6 309 165 3.6 0 3.8 3.3 04/05/2006 05:10:00 14.3 1.5 18.7 10.7 14.2 1.5 18.3 10.7 12.1 1.3 15.6 8.8 309 7 302 165 3.9 0.1 4.3 3.5 04/05/2006 05:20:00 14.8 1.7 18.7 10.3 14.7 1.7 18.3 9.9 12.4 1.7 16.4 8 308 6 304 165 3.8 0.2 4.3 3.5 04/05/2006 05:30:00 15.2 1.4 18.7 10.7 15.1 1.5 18.7 10.7 13.2 1.6 17.2 9.1 310 7 322 165 3.5 0 3.8 3.5 04/05/2006 05:40:00 14.8 1.5 19.9 9.5 14.7 1.5 19.9 9.9 13 1.7 20.2 9.1 312 8 312 165 3.5 0 3.8 3.3 04/05/2006 05:50:00 14.8 1.9 20.2 9.1 14.7 1.8 20.2 9.1 12.8 1.9 19.5 7.6 312 7 317 165 3.6 0 3.8 3.3 04/05/2006 06:00:00 15.7 1.3 19.5 11.5 15.6 1.3 19.5 10.7 13.5 1.5 17.6 9.5 308 8 306 165 3.5 0.1 3.8 3.3 04/05/2006 06:10:00 15.7 1.9 22.1 9.9 15.5 1.9 22.6 9.9 14.2 2.1 23.3 8.8 314 9 323 165 3.5 0 3.8 3.3 04/05/2006 06:20:00 16.4 2.1 23.7 11.5 16.2 2.1 23.7 11.5 14.9 2.2 22.6 7.2 314 8 312 165 3.6 0.1 3.8 3.3 04/05/2006 06:30:00 17.7 1.6 24 13.7 17.5 1.6 24 13.3 16.4 2.2 21.8 9.5 315 8 322 165 3.8 0 4.3 3.5 04/05/2006 06:40:00 16.6 1.8 22.6 12.2 16.5 1.8 22.1 11.5 15.3 2 23.3 10.7 315 8 319 165 3.8 0.1 4.3 3.5 04/05/2006 06:50:00 16.7 1.6 22.1 12.6 16.5 1.6 21.4 12.6 15 1.7 20.2 10.3 313 6 313 165 4 0 4.3 3.8 04/05/2006 07:00:00 17.5 1.9 23.7 10.7 17.3 1.9 23.3 10.7 15.8 1.9 20.6 9.9 313 8 323 165 3.9 0 4.3 3.8 04/05/2006 07:10:00 19.3 1.3 22.1 14.5 19.2 1.3 22.6 14.5 17.5 1.4 21 11.8 311 5 306 165 3.6 0 3.8 3.5 04/05/2006 07:20:00 18.9 1.2 21.4 15.6 18.7 1.2 21 15.6 17.4 1.4 21.4 12.6 312 5 314 165 3.8 0 3.8 3.5 04/05/2006 07:30:00 18.1 1.2 21 14.1 18 1.2 21.4 14.5 16.1 1.3 19.1 11.8 311 5 310 165 3.8 0 4 3.5 04/05/2006 07:40:00 17 1.2 19.9 13.7 16.9 1.2 19.5 13.3 14.4 1.2 17.6 10.3 309 4 309 165 3.8 0.1 4 3.5 04/05/2006 07:50:00 16.1 1.2 19.1 13 16 1.3 19.1 13 13.7 2 18.3 8.4 309 6 310 165 4 0.2 4.5 3.5 04/05/2006 08:00:00 16.3 1.3 20.6 12.6 16.2 1.3 20.6 12.6 14.4 1.5 19.1 10.7 311 5 315 165 4 0 4.5 3.8 04/05/2006 08:10:00 17.8 1 20.6 14.5 17.7 1 20.6 14.9 15.5 1.4 19.1 10.7 310 3 310 165 3.8 0 3.8 3.5 04/05/2006 08:20:00 17.4 1.3 20.2 14.1 17.3 1.3 20.2 14.1 14.6 1.3 18.3 10.7 309 4 305 165 3.7 0 4 3.5 04/05/2006 08:30:00 15 1.5 18.7 11.1 14.9 1.5 18.7 10.3 13 1.3 16.1 9.5 310 5 304 165 4.3 0 4.5 3.8 04/05/2006 08:40:00 14.9 1.1 17.2 10.7 14.8 1.1 17.2 10.3 12.5 1.2 15.3 9.1 309 4 302 165 4.4 0 4.5 3.8 04/05/2006 08:50:00 14.7 1 17.9 11.1 14.5 1 17.6 11.1 12.6 1.3 16.8 9.1 310 4 308 165 4.7 0.1 5 4 04/05/2006 09:00:00 14.5 1.5 17.6 10.3 14.3 1.5 17.6 10.3 12.7 1.5 16.1 9.1 311 6 308 165 4.9 0 5.2 4.5 04/05/2006 09:10:00 13.5 1.5 17.9 9.5 13.4 1.5 17.9 9.5 11.2 1.7 17.2 7.6 306 9 282 165 5 0.1 5.2 4.5 04/05/2006 09:20:00 13.4 2 17.6 8 13.3 2 17.2 8 11.2 1.5 15.3 6.5 308 9 301 165 5 0.2 5.5 4.5 04/05/2006 09:30:00 14.7 2.1 20.6 9.5 14.6 2.1 19.9 9.5 12.2 2 16.8 8 307 8 298 165 5.1 0.1 5.5 4.8 04/05/2006 09:40:00 15.9 2 21.8 9.9 15.9 2 21.8 11.1 13.5 1.9 21.4 9.1 308 7 306 165 5.1 0.1 5.5 5 04/05/2006 09:50:00 16.4 1.7 20.6 10.7 16.3 1.7 19.9 10.7 14 1.9 19.1 9.5 309 6 302 165 5.2 0.1 5.7 4.8 04/05/2006 10:00:00 15.9 1.6 20.6 11.8 15.9 1.6 19.9 11.5 12.7 1.6 17.9 9.1 307 6 300 165 5.2 0 5.5 5 04/05/2006 10:10:00 15 1.9 19.9 10.7 14.8 1.8 19.1 10.7 12.5 1.7 16.8 8 308 8 302 165 5.6 0.1 5.7 5.2 04/05/2006 10:20:00 14.1 1.7 18.3 9.9 13.9 1.8 18.3 9.9 12 1.5 15.6 8.8 308 7 300 165 5.6 0.1 5.7 5.2 04/05/2006 10:30:00 12 1.5 15.3 7.2 11.9 1.5 15.3 7.2 10 1.6 14.1 5.3 304 8 309 165 6 0.2 6.5 5.5 04/05/2006 10:40:00 9.8 1.7 13.3 5.3 9.8 1.6 13.7 4.6 8.3 1.7 13 3 307 11 314 165 6.6 0.1 7 6.2 04/05/2006 10:50:00 8.1 1.5 12.2 4.6 8 1.5 11.8 4.2 6.7 1.5 11.5 3.4 302 13 295 165 7.1 0.1 7.5 6.7 04/05/2006 11:00:00 10.2 2 14.9 4.2 10.2 2 15.3 4.6 9 2 14.9 4.2 290 7 286 165 6.3 0.2 7 6 04/05/2006 11:10:00 11.9 1.5 14.9 6.8 11.9 1.4 14.5 6.8 9.8 1.7 14.5 6.1 295 7 291 165 6 0 6.2 5.7 04/05/2006 11:20:00 11.2 1.6 15.6 7.2 11.2 1.6 15.3 6.8 8.5 1.2 12.6 5.7 301 6 298 165 6.1 0 6.2 6 04/05/2006 11:30:00 9.9 2 13.7 5.7 9.9 2.1 13.7 5.7 7.9 1.6 12.2 4.6 305 8 314 165 6.3 0.1 6.7 6 04/05/2006 11:40:00 12 1.2 15.3 9.5 11.9 1.1 14.9 9.5 10.4 1.8 15.3 6.5 310 5 309 165 6.1 0 6.2 6 04/05/2006 11:50:00 12.7 1.4 15.6 9.1 12.6 1.5 15.6 8.8 11 1.3 15.3 6.8 312 6 305 165 6.3 0 6.5 6.2 04/05/2006 12:00:00 11.7 1 14.9 9.5 11.7 1 14.5 9.1 9.7 1.2 13.3 6.5 308 6 302 165 6.3 0.1 6.5 6.2 04/05/2006 12:10:00 11 1.2 14.1 6.8 10.9 1.2 13.7 7.2 9 1.2 12.2 5.3 308 6 305 165 6.4 0 6.7 6.2 04/05/2006 12:20:00 11.7 1.2 14.9 7.6 11.6 1.3 14.5 7.6 9.6 1.2 12.6 6.1 308 5 302 165 6.6 0 7.3 6.2 04/05/2006 12:30:00 10.9 1.4 14.9 7.2 10.8 1.3 14.5 7.2 9.8 1.3 13 6.5 312 6 307 165 6.6 0 7 6.2 04/05/2006 12:40:00 10.1 1.5 13.7 7.2 10 1.4 13.7 6.5 8.7 1.6 13.3 5.3 310 6 307 165 6.8 0 7 6.7 04/05/2006 12:50:00 9.3 1.2 12.2 5.3 9.2 1.2 12.2 5.3 8.5 1.3 12.6 4.9 315 8 321 165 7.2 0.2 7.5 7 04/05/2006 13:00:00 9 1.1 12.2 6.1 8.9 1.1 12.2 6.1 8.5 1.2 12.2 5.7 316 6 314 165 7.2 0 7.5 7 04/05/2006 13:10:00 9.9 1 13.3 7.2 9.7 1 13 7.2 9.2 1.1 12.6 6.8 317 7 313 165 7 0 7.3 7 04/05/2006 13:20:00 10.4 1.2 13.3 7.2 10.3 1.1 13 7.2 9.3 1.2 11.8 6.1 311 8 304 165 7 0.1 7.5 6.7 04/05/2006 13:30:00 10.8 1.2 14.1 7.2 10.8 1.2 14.1 7.2 8.8 1.2 12.6 5.7 305 7 295 165 6.9 0 7.3 6.7 04/05/2006 13:40:00 11.2 1.5 15.6 6.8 11 1.5 15.6 6.5 9.8 1.7 14.9 5.7 311 8 307 165 6.9 0.1 7.3 6.7 04/05/2006 13:50:00 13 1.4 15.6 9.1 12.8 1.3 15.6 9.5 11.3 1.6 14.9 7.2 312 8 310 165 6.6 0 7 6.2 04/05/2006 14:00:00 12.8 1.6 16.4 8 12.6 1.5 16.1 8 11.9 1.6 15.6 7.6 318 7 313 165 6.7 0 7 6.2 04/05/2006 14:10:00 12.3 1.6 15.6 8.4 12.2 1.5 16.1 8.8 11.1 1.8 16.1 6.5 317 8 317 165 6.7 0 7 6.2 04/05/2006 14:20:00 12.9 1.1 16.4 9.9 12.8 1.1 16.1 9.5 11.9 1.3 14.9 8.8 318 7 321 165 6.5 0 7 6.2 04/05/2006 14:30:00 12.5 1.6 16.1 8.4 12.3 1.6 15.6 8.4 11.8 1.7 15.6 7.6 320 8 319 165 6.4 0.1 7 6 04/05/2006 14:40:00 13.6 1.7 17.9 8.8 13.4 1.5 17.9 8.8 13.1 1.9 17.9 6.8 319 7 316 165 5.9 0.2 6.2 5.5 04/05/2006 14:50:00 14.7 1.3 16.8 10.7 14.4 1.3 16.8 10.7 13.5 1.5 16.8 9.5 314 6 313 165 5.6 0.1 5.7 5.2 04/05/2006 15:00:00 14.1 1.3 17.6 11.1 13.9 1.3 17.2 10.7 13 1.5 16.8 8.8 316 8 311 165 5.3 0 5.5 5.2 04/05/2006 15:10:00 14.5 2 18.7 10.3 14.3 2 18.3 9.9 13.4 2.1 18.3 8.4 316 7 317 165 5.4 0 5.7 5.2 04/05/2006 15:20:00 15.4 1.4 19.1 10.7 15.2 1.3 18.3 10.7 14.2 1.9 18.3 8.8 317 7 328 165 5.4 0 5.7 5.2 04/05/2006 15:30:00 15.9 1.3 18.7 11.5 15.6 1.3 18.7 11.1 14.7 1.7 18.7 10.7 316 5 314 165 5.2 0 5.5 5 04/05/2006 15:40:00 15.9 1.1 17.9 12.6 15.8 1.1 17.9 12.2 14.4 1.5 18.3 9.1 311 5 314 165 5 0 5.2 4.8 04/05/2006 15:50:00 14.4 1.4 17.6 11.1 14.3 1.5 17.2 10.7 13.2 1.5 17.2 9.1 312 6 323 165 4.9 0 5.2 4.8 04/05/2006 16:00:00 13.3 1.7 17.2 9.5 13.1 1.7 16.8 9.1 11.8 1.6 16.4 7.2 311 6 310 165 5.2 0 5.2 5 04/05/2006 16:10:00 12.2 1.1 14.9 8.8 12.1 1.1 14.5 8.8 10.4 1.2 14.1 7.2 310 6 313 165 5.2 0 5.5 5 04/05/2006 16:20:00 11.9 1 14.1 9.1 11.8 1 14.1 9.1 11 1 13.7 8 314 6 311 165 5.2 0 5.5 5 04/05/2006 16:30:00 11.1 1.1 13.3 8 10.9 1 13.3 8 10.4 1.3 13.7 6.8 316 6 326 165 5.3 0 5.5 5 04/05/2006 16:40:00 12.2 1.1 14.5 8.8 11.9 1.1 14.1 9.1 11.7 1.3 14.1 8 316 5 311 165 5.2 0.1 5.5 5 04/05/2006 16:50:00 11.4 0.8 13.3 9.1 11.2 0.7 13 9.5 11.1 1 13.3 8.4 316 4 318 165 5.1 0 5.2 4.5 04/05/2006 17:00:00 11.5 0.8 13.3 9.5 11.3 0.8 13.7 9.1 10.9 0.9 13 7.6 316 5 315 165 5.1 0 5.2 4.8 04/05/2006 17:10:00 11.7 0.9 14.1 9.5 11.5 0.9 14.1 9.5 11.4 1.1 15.3 9.1 316 6 323 165 4.7 0.1 5 4.5 04/05/2006 17:20:00 13.4 1.3 16.1 9.5 13.2 1.3 15.6 9.9 12.8 1.3 16.4 9.1 317 6 316 165 4.3 0.3 4.8 3.5 04/05/2006 17:30:00 13.3 1.3 17.6 9.5 13.1 1.3 17.9 9.5 12.8 1.5 17.2 8 318 7 318 165 3.8 0 4.3 3.5 04/05/2006 17:40:00 12.3 1.3 16.4 8 12.2 1.3 16.1 8 11.4 1.8 16.4 7.2 316 9 325 165 3.6 0 4.3 3.3 04/05/2006 17:50:00 12.6 1.7 17.9 8.8 12.5 1.7 17.6 8.4 12.1 1.7 16.4 8.4 330 12 314 165 3.8 0 4 3.3 04/05/2006 18:00:00 10.8 1.2 14.1 8 10.7 1.2 14.5 8 10.6 1.4 16.1 7.2 326 9 326 165 4 0 4.3 3.5 04/05/2006 18:10:00 10.2 1.6 14.5 4.9 10.2 1.5 14.1 4.9 9.6 1.8 13.7 4.9 317 10 313 165 3.8 0 4 3.5 04/05/2006 18:20:00 10.9 1.5 15.6 7.6 10.8 1.5 15.3 7.6 9.9 1.8 17.9 5.7 314 12 315 165 3.6 0.1 3.8 3 04/05/2006 18:30:00 13.1 2 17.2 7.2 13 2 17.2 7.2 12.4 2.3 17.2 6.8 316 7 311 165 3.5 0.1 3.8 3 04/05/2006 18:40:00 13.4 1.7 18.7 9.1 13.2 1.7 18.7 8.4 12.3 1.5 16.1 7.6 317 9 302 165 3.2 0.2 3.8 2.8 04/05/2006 18:50:00 14.4 1.5 19.5 9.9 14.2 1.6 19.5 10.3 13.1 1.7 16.4 9.5 315 7 307 165 3 0.1 3.3 2.8 04/05/2006 19:00:00 13.1 1.8 18.7 8 12.9 1.8 18.3 8.4 11.9 1.7 16.8 8 313 7 308 165 2.9 0.1 3.3 2.6 04/05/2006 19:10:00 14.7 1.7 18.7 10.7 14.5 1.7 18.3 10.7 14 1.5 17.6 10.3 318 7 317 165 2.9 0 3 2.3 04/05/2006 19:20:00 13.9 1.8 20.6 9.1 13.7 1.8 20.2 9.1 13.2 1.7 17.9 8.4 319 9 310 165 2.8 0 3 2.8 04/05/2006 19:30:00 13.6 1.8 17.9 8.4 13.4 1.8 17.6 8.8 12.5 1.8 16.8 8.4 315 9 299 165 2.7 0 2.8 2.6 04/05/2006 19:40:00 13.6 2.1 18.7 8.8 13.4 2.1 18.3 8.4 12.7 2.3 17.9 7.6 318 10 322 165 2.4 0 2.8 2.3 04/05/2006 19:50:00 13.8 1.5 18.3 9.5 13.7 1.5 17.6 9.9 12.7 1.5 16.8 8.8 313 8 304 165 2.2 0.1 2.6 1.6 04/05/2006 20:00:00 14.9 1.6 17.9 9.9 14.7 1.7 18.3 9.9 13.2 1.6 16.8 8 311 7 307 165 2 0 2.3 1.6 04/05/2006 20:10:00 15.4 2.2 20.6 10.3 15.2 2.2 20.6 10.3 13.6 2.2 20.6 9.1 312 8 302 165 2 0.1 2.3 1.4 04/05/2006 20:20:00 19.1 1.9 25.2 13.7 18.9 1.8 24.4 13.7 18.2 2.3 24.4 11.1 316 7 315 165 2 0.1 2.3 1.4 04/05/2006 20:30:00 20.1 1.9 24.8 14.1 19.9 1.9 25.6 13.7 18.7 2.2 24 13 314 6 310 165 1.9 0.1 2.1 1.4 04/05/2006 20:40:00 17.3 2.9 24 8 17.3 2.9 24.4 8.4 14 3.6 21.8 5.7 308 9 322 165 1.9 0 1.8 1.8 04/05/2006 20:50:00 10.4 3.5 16.8 2.6 10.3 3.6 16.8 1.9 7.6 2.9 16.1 1.1 305 26 318 165 1.9 0 2.1 1.8 04/05/2006 21:00:00 10.4 3.5 17.6 1.1 10.5 3.5 17.2 1.5 7.4 2.8 14.9 1.1 298 29 295 165 1.9 0 2.3 1.8 04/05/2006 21:10:00 13.5 2.5 17.9 5.7 13.5 2.6 18.7 1.9 10.3 2.9 16.4 2.3 308 11 322 165 1.9 0 2.1 1.6 04/05/2006 21:20:00 15.1 2.2 20.2 9.5 15.1 2.2 20.2 9.1 11.7 2.7 17.6 4.9 307 9 309 165 1.7 0 1.8 1.6 04/05/2006 21:30:00 12.8 2.9 19.5 4.6 12.8 3.1 20.2 4.6 10.2 3.5 19.9 2.6 308 12 310 165 1.5 0.1 1.8 1.4 04/05/2006 21:40:00 13.9 2.2 18.3 8 13.9 2.2 19.1 7.2 12.1 2.5 17.2 6.5 312 9 326 165 1.2 0 1.4 1.1 04/05/2006 21:50:00 15.7 2 19.1 9.9 15.7 2 20.2 9.1 13.3 2.3 18.3 6.5 309 7 309 165 1.4 0 1.4 1.4 04/05/2006 22:00:00 18.2 1.7 22.9 13.3 18 1.6 22.9 14.1 16.9 2.3 22.6 11.5 313 6 304 165 1.2 0 1.4 1.1 04/05/2006 22:10:00 19.6 1.7 23.3 15.6 19.4 1.7 23.3 14.5 19.2 2 23.3 13.7 318 5 316 165 1.2 0 1.4 0.9 04/05/2006 22:20:00 22.1 1.4 24.8 17.2 21.9 1.4 24.4 17.2 21.3 1.5 25.2 16.1 314 4 312 165 1.3 0 1.6 1.1 04/05/2006 22:30:00 19.8 1.9 23.7 12.6 19.6 1.9 23.3 13 18.6 2.1 23.3 11.5 315 5 315 165 1.3 0 1.6 1.1 04/05/2006 22:40:00 17.9 1.7 21.8 12.2 17.8 1.7 22.1 12.2 16.3 2 20.6 9.5 313 6 308 165 0.9 0 1.4 0.9 04/05/2006 22:50:00 16.5 2 22.1 10.3 16.5 2.1 22.6 10.3 14.1 2.5 21 5.7 309 7 309 165 0.8 0 0.9 0.7 04/05/2006 23:00:00 14 2 19.9 8.8 14.1 2 19.5 8.8 11.3 2.3 17.9 5.3 306 9 297 165 0.7 0 0.9 0.4 04/05/2006 23:10:00 15.5 2.4 20.2 8.4 15.3 2.4 19.9 6.5 12.4 2.2 16.8 4.6 303 7 302 165 0.5 0 0.7 0.2 04/05/2006 23:20:00 17.2 2.1 21.4 10.3 17.1 2.1 21.4 11.5 14.1 1.7 18.3 8 304 7 298 165 0.5 0 0.7 0.4 04/05/2006 23:30:00 18.6 1.8 22.1 13.3 18.6 1.8 22.1 13.3 14 1.8 18.7 8.8 301 6 305 165 0.6 0 0.7 0.4 04/05/2006 23:40:00 17.4 1.6 21 12.2 17.4 1.6 21 12.2 13.1 1.5 18.3 9.1 299 6 294 165 0.7 0 0.9 0.7 04/05/2006 23:50:00 17.4 1.3 20.2 13.3 17.4 1.3 20.2 13.3 12.5 1.5 16.8 9.1 300 5 297 165 0.5 0 0.7 0.4 04/06/2006 00:00:00 17 1.5 20.6 13.3 17 1.5 20.6 13 13.5 2 20.2 9.1 305 5 307 165 0.5 0 0.7 0.2 04/06/2006 00:10:00 18.7 1.5 21.8 14.9 18.7 1.5 21.8 14.5 15 1.8 19.9 11.1 305 5 304 165 0.6 0 0.7 0.7 04/06/2006 00:20:00 20.2 1.3 22.9 16.1 20.2 1.3 22.9 15.6 16 1.6 20.2 12.2 304 5 310 165 0.5 0 0.7 0.4 04/06/2006 00:30:00 20.3 1.3 23.3 15.6 20.3 1.4 23.3 15.6 16.5 2 21.4 11.1 305 4 304 165 0.5 0 0.7 0.2 04/06/2006 00:40:00 19.7 1.2 22.1 15.3 19.7 1.2 21.8 14.9 16.3 1.7 20.6 11.5 306 4 308 165 0.3 0 0.7 0.2 04/06/2006 00:50:00 19.4 1.2 22.1 15.6 19.5 1.2 22.6 15.6 15.8 1.7 19.5 11.5 305 4 304 165 0.3 0 0.7 0.2 04/06/2006 01:00:00 18.6 1.5 22.1 14.1 18.6 1.5 22.1 14.5 14.3 1.5 19.1 9.9 302 5 298 165 0.2 0 0.2 -0.1 04/06/2006 01:10:00 19.5 1.5 22.9 15.3 19.5 1.5 22.9 15.3 14.3 1.7 20.2 10.3 301 5 296 165 0.2 0 0.4 -0.1 04/06/2006 01:20:00 19.4 1.5 22.1 14.5 19.4 1.5 22.1 14.1 15.6 2.2 20.6 10.7 305 4 304 165 0.1 0 0.2 -0.1 04/06/2006 01:30:00 19.7 1.3 22.1 15.6 19.7 1.3 22.6 15.6 15.9 2.1 20.6 11.1 305 5 302 165 0 0 0.2 -0.1 04/06/2006 01:40:00 18.9 1.5 22.6 15.3 18.9 1.6 22.9 15.3 14.8 2 19.9 9.9 305 4 302 165 0 0 0.2 -0.1 04/06/2006 01:50:00 17.8 1.1 20.6 14.9 17.8 1.1 20.6 15.3 13 1.7 17.6 9.1 303 4 304 165 -0.1 0 0.2 -0.3 04/06/2006 02:00:00 17.4 1.2 21 14.5 17.4 1.2 21 14.1 13.5 1.8 18.3 9.5 306 4 310 165 -0.1 0 -0.1 -0.3 04/06/2006 02:10:00 16.5 1.8 20.6 10.7 16.5 1.8 20.6 11.1 11.7 1.5 15.6 8.4 300 5 297 165 -0.1 0 -0.1 -0.3 04/06/2006 02:20:00 14.1 1.1 17.2 10.7 14.2 1.1 17.6 10.7 12 1.7 16.4 8.8 293 7 293 165 -0.2 0 -0.1 -0.3 04/06/2006 02:30:00 15 1.1 17.6 12.2 15 1.1 17.6 12.2 11.4 1.5 16.1 8.4 299 6 296 165 -0.3 0 -0.1 -0.5 04/06/2006 02:40:00 16 1 18.7 13 15.9 1.1 19.1 13 12.2 1.5 16.4 8.8 304 6 301 165 -0.3 0 -0.3 -0.5 04/06/2006 02:50:00 15.6 1 18.7 13.3 15.5 1 19.1 13 13.8 1.5 17.6 10.3 311 6 307 165 -0.3 0 -0.3 -0.5 04/06/2006 03:00:00 14.3 1.2 17.2 10.3 14.2 1.2 16.8 10.3 12.2 1.5 16.1 8 309 6 317 165 -0.3 0 -0.1 -0.5 04/06/2006 03:10:00 14.7 1 17.2 12.2 14.6 1 17.6 11.8 10.6 1.2 14.9 7.6 302 5 302 165 -0.6 0 -0.5 -0.8 04/06/2006 03:20:00 14.8 1.3 18.3 11.5 14.7 1.3 17.9 11.1 10.9 1.2 16.1 8.4 304 4 304 165 -0.5 0 -0.5 -0.8 04/06/2006 03:30:00 13.8 1.1 17.2 10.7 13.8 1.2 16.8 10.7 10.8 1.5 15.3 7.6 298 7 294 165 -0.6 0 -0.5 -0.8 04/06/2006 03:40:00 13 1.7 17.2 8.8 12.9 1.7 17.2 8.4 9.9 1.5 15.3 6.5 301 6 299 165 -0.5 0 -0.5 -0.8 04/06/2006 03:50:00 12.8 1.3 15.3 9.1 12.8 1.3 15.6 9.5 10 1.1 13 7.2 306 6 302 165 -0.7 0 -0.5 -0.8 04/06/2006 04:00:00 12.6 1.3 16.1 9.1 12.5 1.3 16.1 8.8 11.2 1.3 15.3 8 311 7 302 165 -0.8 0 -0.5 -1 04/06/2006 04:10:00 12.4 1.3 14.9 8.8 12.2 1.3 15.3 8.4 11.2 1.3 14.5 7.2 313 7 319 165 -0.8 0 -0.8 -1.2 04/06/2006 04:20:00 9.8 1.8 14.5 5.3 9.8 1.7 14.1 5.3 8.6 1.7 12.6 3 313 9 305 165 -1 0 -0.8 -1.2 04/06/2006 04:30:00 8.5 1.6 13.3 4.9 8.5 1.6 13.3 4.9 7.3 1.8 11.5 2.3 313 12 340 165 -1.1 0 -0.8 -1.2 04/06/2006 04:40:00 14.7 3.2 21 6.8 14.6 3.2 21 7.2 11.9 1.8 17.6 5.3 308 7 298 165 -0.9 0.1 -0.8 -1.2 04/06/2006 04:50:00 18.7 1.5 22.1 14.5 18.6 1.5 21.8 14.5 15.2 1.7 19.9 10.7 307 5 300 165 -0.8 0 -0.5 -0.8 04/06/2006 05:00:00 18.7 1.3 22.1 13.3 18.7 1.3 21.8 13.3 15.3 1.8 19.9 10.7 307 4 303 165 -0.8 0 -0.5 -0.8 04/06/2006 05:10:00 13 3.2 19.9 3 13 3.1 19.9 3.4 10.4 3.2 16.8 2.6 302 11 307 165 -0.9 0 -0.8 -1.2 04/06/2006 05:20:00 6 2.7 14.5 0.7 6.1 2.7 13.7 1.1 4.9 2.1 13 1.1 288 33 297 165 -1.1 0 -1 -1.4 04/06/2006 05:30:00 7.8 1.7 11.8 4.2 7.8 1.7 12.2 4.2 6.2 1.7 11.8 2.3 308 12 318 165 -1.2 0 -1 -1.4 04/06/2006 05:40:00 6.5 3.1 13.7 0.7 6.5 3.2 13.3 0.7 5.4 3.1 13.3 0.4 286 32 285 165 -1.1 0 -1 -1.2 04/06/2006 05:50:00 9.8 2.5 15.3 4.6 9.8 2.4 15.6 4.6 7.8 2.1 14.5 3.4 298 10 293 165 -0.9 0 -0.8 -1.2 04/06/2006 06:00:00 10.9 2.2 16.8 6.1 10.9 2.1 16.8 6.1 9.1 2 16.8 5.3 303 11 298 165 -0.7 0 -0.3 -1.2 04/06/2006 06:10:00 12.7 2.2 19.5 7.6 12.6 2.2 19.1 7.6 10.6 2 16.1 6.1 303 9 297 165 -0.7 0.1 -0.5 -0.8 04/06/2006 06:20:00 13 1.8 18.3 8.8 12.9 1.8 18.3 8.8 10.6 1.8 16.4 6.8 305 7 300 165 -1 0.2 -0.8 -1.4 04/06/2006 06:30:00 11.9 1.5 15.3 8.8 11.8 1.5 15.3 8.8 9.4 1.5 14.9 5.3 303 6 309 165 -1.3 0 -1.2 -1.4 04/06/2006 06:40:00 12.6 1.1 15.6 9.1 12.6 1 14.9 9.1 9.9 1.5 13.3 6.5 305 6 304 165 -1.3 0 -1.2 -1.4 04/06/2006 06:50:00 13.6 1.3 16.4 9.5 13.6 1.3 16.4 9.5 10.9 1.4 14.1 7.2 306 6 300 165 -1.2 0 -0.8 -1.4 04/06/2006 07:00:00 13 1.5 16.4 8.8 13 1.5 16.8 9.1 9.8 1.3 14.1 6.8 301 6 300 165 -1 0 -0.8 -1.2 04/06/2006 07:10:00 13.6 1.5 18.3 10.3 13.6 1.5 17.9 10.3 10.4 1.8 16.8 6.8 298 6 298 165 -1 0 -0.8 -1.2 04/06/2006 07:20:00 10.2 2.1 16.4 5.7 10.1 2 16.1 5.3 8.1 1.8 15.3 4.6 298 9 300 165 -0.9 0.1 -0.5 -1.2 04/06/2006 07:30:00 11.1 1.5 14.5 7.6 11 1.5 14.5 7.6 8.6 1.5 13.3 5.3 296 6 304 165 -0.7 0 -0.5 -0.8 04/06/2006 07:40:00 10.6 1.2 13.7 6.8 10.5 1.2 13.7 6.8 8.2 1.2 11.5 5.3 302 6 298 165 -0.8 0.1 -0.5 -0.8 04/06/2006 07:50:00 11.4 1 14.5 8.8 11.4 1.1 14.5 8.8 8.6 1.1 13.3 6.1 301 7 304 165 -1 0 -0.8 -1.2 04/06/2006 08:00:00 11.9 0.8 13.7 9.9 12 0.8 13.7 9.9 9.3 1.1 12.6 6.1 296 3 290 165 -1 0 -0.8 -1.2 04/06/2006 08:10:00 12.5 1.3 16.1 9.5 12.6 1.3 16.1 9.5 9.9 1.5 13.7 5.7 295 5 293 165 -1 0 -0.8 -1.2 04/06/2006 08:20:00 11.6 1.5 14.9 8 11.5 1.5 14.9 7.6 9.2 1.5 13.3 4.9 301 8 298 165 -0.7 0 -0.5 -1 04/06/2006 08:30:00 12.5 1.7 16.1 7.2 12.5 1.7 15.6 7.6 9.3 1.3 13.7 6.5 300 6 301 165 -0.4 0 -0.3 -0.5 04/06/2006 08:40:00 11.9 1.3 15.6 8 11.9 1.3 15.3 8 9.8 1.3 14.5 6.5 308 6 312 165 -0.2 0 0.2 -0.5 04/06/2006 08:50:00 12.5 1.5 16.8 8.4 12.5 1.5 16.8 8 10.4 1.7 16.4 7.2 308 5 310 165 -0.1 0 0.2 -0.3 04/06/2006 09:00:00 11.4 1.4 14.5 6.5 11.3 1.4 14.5 6.5 8.5 1.2 12.6 5.7 303 6 302 165 0.1 0 0.2 -0.1 04/06/2006 09:10:00 11 1.4 13.7 6.5 11 1.3 13.7 6.8 8.1 1.2 11.8 5.3 301 5 301 165 0.2 0 0.4 -0.1 04/06/2006 09:20:00 8.4 1.5 12.2 5.3 8.4 1.5 12.2 5.3 6.8 1.3 11.1 3 298 7 295 165 0.4 0 0.7 0.2 04/06/2006 09:30:00 8.3 1 12.2 5.7 8.4 1 12.2 5.7 7.7 1.2 11.1 4.6 292 7 293 165 0.5 0 0.9 0.2 04/06/2006 09:40:00 9.1 1.5 12.2 4.6 9.2 1.5 12.2 4.6 8.4 1.7 11.8 4.2 291 7 290 165 0.5 0.2 0.9 -0.1 04/06/2006 09:50:00 11.6 0.8 13.3 9.1 11.7 0.8 13.3 9.5 9.8 1.3 12.6 6.1 293 4 291 165 0.2 0 0.2 -0.1 04/06/2006 10:00:00 10.7 0.9 12.6 8.8 10.8 0.9 12.6 8.4 8.2 1 11.5 5.3 298 4 295 165 0.5 0 0.7 0.2 04/06/2006 10:10:00 10.6 1 12.6 7.6 10.7 1 13 7.2 8.4 1.3 11.8 5.3 296 5 292 165 0.5 0 0.7 -0.1 04/06/2006 10:20:00 10.9 1.1 13.3 8 11 1.1 13.3 7.2 8.7 1.1 11.8 5.3 297 6 300 165 0.5 0.1 0.9 0.2 04/06/2006 10:30:00 10.7 1 13.7 7.6 10.8 1 14.1 8 8.2 1.3 11.8 5.7 298 5 293 165 0.7 0.1 0.9 0.2 04/06/2006 10:40:00 10.1 1 12.2 7.2 10.1 1 12.2 7.2 7.5 0.9 10.7 5.3 303 5 301 165 0.9 0 1.4 0.7 04/06/2006 10:50:00 10.4 0.7 12.2 8.4 10.5 0.7 12.2 8.4 7.6 1 10.3 5.7 304 3 302 165 1 0.1 1.4 0.7 04/06/2006 11:00:00 9.2 1 12.6 6.5 9.2 1 12.2 6.1 7.4 1.1 11.8 4.9 306 7 316 165 1.5 0.3 1.8 0.9 04/06/2006 11:10:00 8.5 0.7 10.7 6.1 8.6 0.7 10.7 6.5 7 1 9.9 4.6 294 6 298 165 1.7 0 1.8 1.6 04/06/2006 11:20:00 8.8 1 11.5 5.3 8.9 1 11.1 5.3 7.7 1.2 10.7 4.6 292 6 301 165 1.7 0 1.8 1.4 04/06/2006 11:30:00 10.5 0.9 13 7.2 10.5 0.9 12.6 7.6 7.7 1 10.7 5.7 302 5 303 165 1.6 0.1 1.8 1.1 04/06/2006 11:40:00 9.5 0.9 11.8 7.6 9.5 0.9 11.8 7.6 7.4 1 10.7 4.9 304 5 305 165 1.8 0 2.3 1.4 04/06/2006 11:50:00 7.8 1.8 10.7 3 7.8 1.8 10.7 3.4 6.8 1.6 10.7 3 292 9 293 165 1.8 0.1 2.3 1.4 04/06/2006 12:00:00 7.7 1.3 10.3 3.4 8 1.2 10.7 3.4 7.6 1.4 10.7 3.8 283 9 282 165 2.2 0 2.6 1.8 04/06/2006 12:10:00 9.7 0.7 11.8 8 9.8 0.7 11.8 7.6 8.6 1.1 11.5 5.7 292 7 291 165 2 0 2.3 1.8 04/06/2006 12:20:00 8.8 0.7 10.3 6.5 8.7 0.7 10.3 6.1 7.6 1.1 10.3 4.6 309 7 308 165 2.4 0.2 2.8 1.8 04/06/2006 12:30:00 8.4 1 11.1 6.5 8.4 1 11.1 6.1 6.8 1.1 10.3 4.6 299 7 302 165 2.4 0.1 2.8 1.8 04/06/2006 12:40:00 8 1.5 10.7 3 8 1.4 10.7 4.2 6.5 1.1 10.7 3.4 301 9 301 165 2.6 0.1 3 1.8 04/06/2006 12:50:00 7.3 1.1 10.3 2.6 7.3 1 9.9 2.6 6.2 1.1 9.1 2.6 300 10 304 165 3 0.1 3.3 2.6 04/06/2006 13:00:00 6.3 1.3 9.1 3 6.4 1.4 9.5 3 5.8 1.5 9.5 2.3 292 13 295 165 3 0.2 3.5 2.8 04/06/2006 13:10:00 7.1 1.5 10.7 3.8 7.1 1.5 10.7 3.4 6 1.5 10.7 2.6 310 12 324 165 3.6 0 4 3.3 04/06/2006 13:20:00 7.1 0.9 8.8 4.6 7.1 0.9 9.1 4.9 5.8 0.8 8.4 3.8 305 7 302 165 3.4 0 3.5 3.3 04/06/2006 13:30:00 6.5 0.9 8.8 3.4 6.5 0.8 8.8 3.8 5.7 1 8 3 307 8 310 165 3.5 0 3.5 3.3 04/06/2006 13:40:00 5.3 0.8 8 3.8 5.3 0.8 7.6 3.8 4.8 0.8 7.2 2.6 310 10 305 165 3.8 0.2 4.3 3.5 04/06/2006 13:50:00 6 1 7.6 3.8 5.9 1 8 3.8 5.3 0.9 8 3 312 9 300 165 4.1 0.1 4.5 3.8 04/06/2006 14:00:00 6.6 0.7 8.4 4.9 6.6 0.7 8.4 4.9 5.3 0.7 8 3.8 306 6 300 165 3.8 0.2 4.3 3.5 04/06/2006 14:10:00 6.5 0.6 8.4 4.9 6.4 0.6 8 4.9 5.6 1 8.4 3.8 310 6 322 165 3.6 0 4 3.5 04/06/2006 14:20:00 6.4 0.5 7.6 5.3 6.4 0.5 7.6 5.3 6.4 0.5 7.6 4.9 322 4 323 165 4.1 0 4.5 4 04/06/2006 14:30:00 6.3 0.6 7.6 4.6 6.3 0.6 7.6 4.6 5.6 0.7 7.2 3.8 312 8 312 165 4.3 0.2 4.5 4 04/06/2006 14:40:00 6.4 0.7 8.4 4.6 6.3 0.7 8.4 4.6 6.2 0.8 8 4.2 317 5 317 165 4.3 0 4.5 4.3 04/06/2006 14:50:00 6.8 0.4 7.6 5.3 6.7 0.4 7.6 5.3 6.6 0.5 8 4.9 318 4 319 165 4.3 0 4.5 4.3 04/06/2006 15:00:00 6.3 0.6 8 4.6 6.2 0.6 8 4.6 6.2 0.5 7.6 4.6 320 6 323 165 4.3 0 4.8 4.3 04/06/2006 15:10:00 5.7 0.9 7.2 3 5.7 0.9 7.2 2.3 5.6 0.8 7.2 3 325 9 322 165 4.8 0.2 5.2 4 04/06/2006 15:20:00 5.4 1 6.8 2.6 5.4 1 6.8 2.6 5.1 1.1 6.8 2.3 313 7 317 165 4.4 0 4.8 4.3 04/06/2006 15:30:00 5.2 0.6 6.8 3 5.1 0.6 6.8 3 5.2 0.6 6.8 3.4 323 10 305 165 4.8 0.2 5.2 4.3 04/06/2006 15:40:00 4.5 0.8 6.5 2.3 4.5 0.8 6.5 2.3 4.1 1.1 6.8 1.5 311 15 298 165 4.9 0.1 5.5 4.8 04/06/2006 15:50:00 4 1.1 5.7 1.1 3.8 1.3 6.1 1.1 3.7 1.1 5.7 0.7 327 20 322 165 5.2 0.1 5.7 5 04/06/2006 16:00:00 4.1 1 5.7 1.5 3.9 1.2 5.7 1.1 3.6 0.8 5.7 1.1 322 24 281 165 5.4 0.3 6.2 4.8 04/06/2006 16:10:00 4.3 0.5 5.7 2.6 4.2 0.5 5.7 3 3.9 0.6 5.7 2.3 321 15 347 165 5.2 0.3 5.7 4.8 04/06/2006 16:20:00 5.1 0.7 6.8 3.4 4.7 1.1 6.8 1.9 4.9 0.8 6.8 3 349 11 335 165 5.8 0.1 6.2 5.5 04/06/2006 16:30:00 4.6 0.7 6.5 3 3.7 0.8 6.1 1.9 4.5 0.7 6.8 3 357 11 356 165 5.2 0.1 5.7 5 04/06/2006 16:40:00 5.2 0.7 6.8 3.4 5 0.8 6.8 2.6 5 0.7 7.2 3.4 335 15 353 165 5.2 0 5.5 5 04/06/2006 16:50:00 5.4 0.6 7.2 3.8 5 0.9 7.6 2.3 5.4 0.6 7.6 3.8 349 6 348 165 5.2 0 5.5 5 04/06/2006 17:00:00 5.2 0.6 7.6 3.4 4.3 1 7.2 2.3 5.1 0.6 7.2 3 351 8 349 165 5.3 0 5.5 5 04/06/2006 17:10:00 5.2 0.7 6.8 3.8 4.7 1.2 7.2 1.9 5.1 0.7 6.8 3.8 343 13 341 165 5.2 0 5.2 5 04/06/2006 17:20:00 5.3 0.7 7.6 3.8 5 1 8 2.3 5.3 0.7 8.4 3.8 347 8 358 165 5.1 0 5.2 4.8 04/06/2006 17:30:00 5 0.6 6.8 3.8 4.3 1.1 6.8 1.9 5 0.6 6.8 3.8 349 9 338 165 4.9 0 5.2 4.8 04/06/2006 17:40:00 4.9 0.7 6.5 2.6 4.5 1 6.5 2.3 4.7 0.7 6.8 3 347 9 338 165 4.9 0 5.2 4.8 04/06/2006 17:50:00 5 0.6 6.1 3 4.5 0.8 6.5 2.6 4.9 0.7 6.5 3 349 8 351 165 4.9 0.1 5.2 4.5 04/06/2006 18:00:00 4.8 0.6 7.2 3.4 4.6 0.8 7.2 1.9 4.8 0.7 7.6 3 341 9 338 165 4.6 0 4.8 4.5 04/06/2006 18:10:00 4.8 0.6 6.1 3.4 4.6 0.8 6.5 2.3 4.7 0.6 6.5 3 342 9 334 165 4.6 0 5 4.3 04/06/2006 18:20:00 4.6 0.9 6.8 3 4.6 1 6.8 2.3 4.5 0.9 6.5 2.6 339 8 340 165 4.1 0.2 4.8 3.5 04/06/2006 18:30:00 4.5 0.6 6.1 3.4 4.2 1 6.1 1.5 4.6 0.5 6.1 3 346 9 352 165 3.9 0 4.3 3.5 04/06/2006 18:40:00 4.7 0.5 6.1 3.8 4.6 0.5 5.7 3.4 4.6 0.5 6.1 3.4 330 6 332 165 3.6 0.1 4 3.5 04/06/2006 18:50:00 4.6 0.4 5.7 3.8 4.5 0.4 5.3 3.8 4.5 0.4 5.7 3.4 328 8 333 165 3.3 0 3.5 3 04/06/2006 19:00:00 4.7 0.5 6.1 3.4 4.6 0.6 6.1 2.6 4.5 0.5 5.7 3 336 11 341 165 3 0.2 3.5 2.6 04/06/2006 19:10:00 4.5 0.5 5.7 3 4.4 0.6 6.1 2.6 4.5 0.6 6.1 3 339 6 354 165 2.9 0.1 3.5 2.3 04/06/2006 19:20:00 4.3 0.5 5.7 2.6 4.2 0.6 6.1 2.6 4.2 0.6 5.3 2.6 341 8 341 165 2.5 0.2 2.8 1.8 04/06/2006 19:30:00 4.4 0.5 5.3 3 4.3 0.5 5.7 2.6 4.2 0.5 5.3 2.6 335 11 348 165 2.1 0 2.3 1.8 04/06/2006 19:40:00 3.9 0.5 4.9 2.3 3.8 0.5 4.9 2.6 3.8 0.5 4.9 2.6 334 7 335 165 1.8 0 1.8 1.6 04/06/2006 19:50:00 3.9 0.5 5.3 2.6 3.9 0.5 5.3 2.6 3.7 0.5 4.9 2.6 334 8 333 165 1.6 0.1 1.8 1.4 04/06/2006 20:00:00 3.8 0.5 5.3 2.6 3.8 0.6 5.3 1.9 3.6 0.4 4.9 2.6 340 8 353 165 1.3 0 1.6 1.1 04/06/2006 20:10:00 4.7 0.7 6.1 3 4.6 0.8 6.5 2.6 4.5 0.8 6.1 3 344 6 338 165 1.1 0 1.4 0.9 04/06/2006 20:20:00 4.2 0.7 6.1 2.3 3.4 1.1 6.1 1.1 4.2 0.6 5.7 2.6 358 9 345 165 1.1 0 1.4 0.9 04/06/2006 20:30:00 4.5 0.6 5.7 3.4 3.6 1.1 6.1 1.9 4.4 0.5 5.7 3 355 8 359 165 1.1 0 1.4 0.9 04/06/2006 20:40:00 4.7 0.4 6.1 3.4 3.4 1 6.1 1.9 4.7 0.5 6.5 3.4 359 9 343 165 0.9 0 1.1 0.9 04/06/2006 20:50:00 4.9 0.5 6.1 3.4 3.5 1 6.1 1.9 4.9 0.5 6.1 3.8 356 7 359 165 0.9 0 1.1 0.7 04/06/2006 21:00:00 5.4 0.6 6.8 3.8 5.3 0.7 6.8 2.6 5.4 0.5 6.5 4.2 346 6 347 165 0.7 0 0.9 0.7 04/06/2006 21:10:00 5.1 0.6 6.5 3.8 4.9 0.8 6.8 2.6 4.9 0.5 6.1 3.8 348 6 340 165 0.5 0 0.9 0.2 04/06/2006 21:20:00 5.7 0.6 7.2 4.2 5 1 6.8 2.6 5.5 0.6 6.8 4.2 350 6 5 165 0.5 0 0.7 0.2 04/06/2006 21:30:00 5.6 0.6 7.2 3.8 4.9 0.9 7.6 2.6 5.5 0.7 7.6 3.8 351 6 352 165 0.6 0 0.9 0.7 04/06/2006 21:40:00 5 1 6.8 3 4.2 1.3 6.8 1.5 4.9 0.9 6.5 3 352 7 353 165 0.4 0.1 0.7 0.2 04/06/2006 21:50:00 4.7 0.6 6.1 3.4 3.5 1 6.1 1.9 4.4 0.6 5.7 3 354 5 350 165 0.2 0 0.4 0.2 04/06/2006 22:00:00 3.4 0.5 4.6 2.3 3.2 0.5 4.6 1.9 3.4 0.5 4.9 2.3 341 7 343 165 0.3 0 0.4 0.2 04/06/2006 22:10:00 1.7 0.6 3.4 0.4 1.4 0.7 3.4 0.4 2.2 0.5 3.8 0.7 0 21 6 165 0.4 0.1 0.7 -0.1 04/06/2006 22:20:00 2.4 0.5 3.8 1.5 1.7 0.5 3.4 0.4 2.8 0.5 4.2 1.5 355 7 3 165 0.4 0.1 0.7 0.2 04/06/2006 22:30:00 3 0.5 4.2 1.9 2.6 0.7 4.2 0.7 3.2 0.5 4.6 1.9 348 7 343 165 0.2 0 0.4 0.2 04/06/2006 22:40:00 3.3 0.4 4.6 2.3 2.2 0.6 3.8 1.1 3.5 0.5 4.9 2.3 2 8 3 165 0.2 0 0.4 -0.1 04/06/2006 22:50:00 2.6 0.5 3.4 1.5 1.9 0.5 3 0.7 2.8 0.5 3.8 1.5 7 8 351 165 0.1 0 0.2 -0.1 04/06/2006 23:00:00 2 0.5 3 1.1 1.4 0.4 2.6 0.4 2.2 0.5 3.4 1.1 12 11 5 165 0.1 0 0.2 -0.1 04/06/2006 23:10:00 0.7 0.3 1.5 0.4 0.5 0.2 1.5 0.4 1 0.3 1.5 0.4 357 9 5 165 0.2 0 0.2 -0.1 04/06/2006 23:20:00 1.1 0.4 1.9 0.4 0.6 0.4 1.5 0.4 1.4 0.3 2.3 0.7 353 0 353 165 0.1 0 0.2 -0.1 04/06/2006 23:30:00 0.4 0.1 1.1 0.4 0.4 0 0.4 0.4 0.6 0.3 1.1 0.4 352 0 353 165 0 0 0.2 -0.1 04/06/2006 23:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 352 0 165 165 -0.1 0 0.2 -0.1 04/06/2006 23:50:00 0.4 0.1 1.1 0.4 0.4 0.1 1.5 0.4 0.4 0 0.7 0.4 310 39 269 165 -0.2 0.1 -0.1 -0.5 04/07/2006 00:00:00 0.4 0.2 1.1 0.4 0.4 0.1 1.1 0.4 0.4 0.1 1.1 0.4 270 0 270 165 -0.1 0 0.2 -0.5 04/07/2006 00:10:00 0.4 0.1 1.1 0.4 0.4 0 0.4 0.4 0.4 0.1 0.7 0.4 269 1 270 165 0 0 0.2 -0.1 04/07/2006 00:20:00 1.7 0.7 3.4 0.4 1.5 0.8 3.4 0.4 1.3 0.6 3 0.4 292 13 293 165 0.2 0.1 0.4 -0.1 04/07/2006 00:30:00 3.1 0.3 3.8 2.3 3.1 0.3 3.8 2.3 2.5 0.4 4.2 1.5 296 4 292 165 0.2 0 0.4 -0.1 04/07/2006 00:40:00 3.2 0.2 3.8 2.6 3.2 0.2 3.8 2.6 2.6 0.4 3.8 1.9 298 3 295 165 0.4 0 0.7 0.2 04/07/2006 00:50:00 2.8 0.3 3.4 2.3 2.8 0.3 3.4 1.9 2.4 0.3 3 1.5 303 4 300 165 0.3 0 0.7 0.2 04/07/2006 01:00:00 2.5 0.3 3 1.5 2.4 0.3 3 1.5 2.1 0.3 3 1.5 301 2 301 165 0.5 0 0.9 0.4 04/07/2006 01:10:00 2.2 0.4 3 1.1 2.2 0.4 3 0.7 2 0.4 3 0.7 301 10 299 165 0.6 0 0.9 0.2 04/07/2006 01:20:00 2.6 0.5 3.8 1.1 2.6 0.6 3.8 1.1 2.2 0.5 3.8 1.1 299 8 285 165 0.6 0 0.9 0.4 04/07/2006 01:30:00 3.2 0.5 4.2 2.3 3.1 0.5 4.2 1.9 3.1 0.4 4.2 1.5 288 3 287 165 0.5 0 0.7 0.2 04/07/2006 01:40:00 2.3 0.4 3 1.5 2 0.4 3 1.1 2.5 0.5 3.8 1.5 294 5 295 165 0.4 0 0.7 0.2 04/07/2006 01:50:00 1.7 0.3 2.3 1.1 1.4 0.3 2.3 0.4 1.6 0.4 2.6 0.7 296 5 297 165 0.5 0.1 0.9 0.2 04/07/2006 02:00:00 1.3 0.4 2.6 0.4 1.1 0.5 2.3 0.4 1.3 0.5 2.6 0.4 284 10 276 165 0.9 0 1.1 0.7 04/07/2006 02:10:00 0.8 0.3 1.5 0.4 0.5 0.2 1.5 0.4 1.1 0.3 1.5 0.4 294 7 287 165 0.7 0 0.9 0.4 04/07/2006 02:20:00 1.3 0.5 2.3 0.4 1 0.5 2.3 0.4 0.9 0.4 2.3 0.4 296 13 286 165 0.7 0.1 0.9 0.4 04/07/2006 02:30:00 1.3 0.3 2.3 0.7 1 0.4 2.3 0.4 1.3 0.3 1.9 0.7 300 6 297 165 0.9 0 1.1 0.7 04/07/2006 02:40:00 1.2 0.4 2.3 0.7 0.8 0.5 1.9 0.4 1.6 0.2 2.3 1.1 315 3 317 165 0.9 0 1.4 0.9 04/07/2006 02:50:00 1.6 0.3 2.3 0.7 1.3 0.3 1.9 0.7 1.6 0.3 2.3 0.7 316 3 317 165 1.1 0 1.4 0.9 04/07/2006 03:00:00 0.6 0.3 1.1 0.4 0.4 0.1 1.1 0.4 0.8 0.4 1.5 0.4 311 0 310 165 1.2 0 1.4 0.9 04/07/2006 03:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0.1 0.7 0.4 36 51 165 165 1.2 0 1.4 0.9 04/07/2006 03:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0.2 0.7 0.4 44 22 165 165 1.4 0 1.6 1.1 04/07/2006 03:30:00 1.2 0.5 1.9 0.4 0.7 0.5 1.9 0.4 1.2 0.4 1.9 0.4 325 6 322 165 1.6 0 1.8 1.4 04/07/2006 03:40:00 1 0.6 2.3 0.4 0.8 0.5 1.9 0.4 1.2 0.5 1.9 0.4 318 6 322 165 1.8 0 1.8 1.4 04/07/2006 03:50:00 0.4 0.1 0.7 0.4 0.4 0 0.4 0.4 0.4 0.1 0.7 0.4 282 13 270 165 1.8 0 1.8 1.6 04/07/2006 04:00:00 1.4 1 3.4 0.4 1.3 1 3.8 0.4 1.6 0.9 3.4 0.4 273 9 282 165 1.7 0 1.8 1.4 04/07/2006 04:10:00 2.8 0.3 3.4 1.9 2.7 0.3 3.4 1.5 2.8 0.4 3.8 1.9 291 5 281 165 1.5 0 1.8 1.4 04/07/2006 04:20:00 3.1 0.3 4.2 2.3 3 0.4 4.2 2.3 3.2 0.4 4.2 1.9 286 4 284 165 1.8 0 1.8 1.6 04/07/2006 04:30:00 3.4 0.3 4.2 2.6 3.4 0.3 4.2 2.3 3 0.5 4.2 1.9 291 6 281 165 1.8 0 1.8 1.6 04/07/2006 04:40:00 2.4 0.5 3.4 1.5 2.3 0.5 3.4 1.1 2.2 0.4 3 1.5 298 5 293 165 2 0 2.3 1.8 04/07/2006 04:50:00 1.4 0.5 2.3 0.4 1.4 0.5 2.3 0.4 1.7 0.4 2.6 0.7 305 3 304 165 2.1 0 2.3 1.8 04/07/2006 05:00:00 0.6 0.3 1.5 0.4 0.4 0.2 1.1 0.4 0.9 0.3 1.9 0.4 298 13 302 165 2.3 0 2.3 2.3 04/07/2006 05:10:00 0.7 0.3 1.5 0.4 0.5 0.2 1.5 0.4 1 0.2 1.5 0.4 280 9 282 165 2.2 0 2.6 1.8 04/07/2006 05:20:00 1.6 0.5 2.6 0.4 1.4 0.5 2.3 0.4 1.9 0.4 2.6 0.7 311 9 310 165 1.5 0.3 2.1 0.9 04/07/2006 05:30:00 2.2 0.2 2.6 1.5 1.8 0.2 2.3 1.1 1.8 0.3 2.6 1.1 301 6 300 165 1.2 0.1 1.4 0.9 04/07/2006 05:40:00 2.3 0.8 3.4 0.4 2.1 1 3.4 0.4 2 0.7 3.4 0.4 280 16 294 165 1.4 0 1.6 1.4 04/07/2006 05:50:00 1.5 0.2 2.3 0.7 1.1 0.3 1.9 0.4 1.3 0.4 1.9 0.4 258 12 261 165 1.4 0 1.6 1.1 04/07/2006 06:00:00 1.5 0.2 1.9 1.1 1.3 0.2 1.9 0.7 1.8 0.3 2.3 1.1 284 3 278 165 1.8 0 1.8 1.4 04/07/2006 06:10:00 1.6 0.2 2.3 1.1 1.4 0.2 1.9 1.1 1.8 0.3 2.3 0.7 287 4 285 165 1.9 0 1.8 1.6 04/07/2006 06:20:00 1.8 0.3 2.3 1.1 1.7 0.3 2.3 0.7 1.7 0.3 2.6 1.1 295 2 297 165 1.9 0 1.8 1.8 04/07/2006 06:30:00 1.6 0.4 2.6 0.7 1.4 0.4 2.3 0.7 1.7 0.4 2.6 0.7 298 3 296 165 1.9 0 2.1 1.8 04/07/2006 06:40:00 1.2 0.3 1.9 0.7 0.9 0.4 1.5 0.4 1.4 0.3 2.3 0.7 297 2 296 165 2 0 2.1 1.8 04/07/2006 06:50:00 1.4 0.3 1.9 0.4 1.3 0.3 1.9 0.4 1.6 0.3 2.3 0.7 281 6 279 165 2.2 0.1 2.6 1.8 04/07/2006 07:00:00 1.5 0.3 2.3 0.7 1.5 0.3 2.3 0.7 1.8 0.3 2.3 0.7 264 7 254 165 2.5 0 2.8 2.6 04/07/2006 07:10:00 1.4 0.4 2.6 0.4 1.5 0.3 2.3 0.7 1.8 0.2 2.3 1.1 260 6 255 165 2.7 0 2.8 2.6 04/07/2006 07:20:00 0.7 0.4 1.5 0.4 0.6 0.4 1.5 0.4 1.1 0.4 1.9 0.4 265 9 258 165 3 0 3.3 2.8 04/07/2006 07:30:00 0.4 0.1 0.7 0.4 0.4 0.1 1.1 0.4 0.6 0.3 1.5 0.4 249 4 276 165 3.1 0 3.3 3 04/07/2006 07:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 247 0 165 165 3.2 0 3.3 3 04/07/2006 07:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 247 0 165 165 3.1 0 3.3 3 04/07/2006 08:00:00 0.4 0.1 1.1 0.4 0.4 0.1 1.1 0.4 0.5 0.2 1.1 0.4 247 0 247 165 3 0 3.3 2.8 04/07/2006 08:10:00 1 0.3 1.9 0.4 1 0.3 1.9 0.4 1.3 0.3 1.9 0.4 252 9 241 165 2.8 0 3 2.6 04/07/2006 08:20:00 0.8 0.4 1.5 0.4 0.5 0.3 1.5 0.4 1.2 0.3 1.9 0.7 234 6 238 165 3.1 0 3.3 2.8 04/07/2006 08:30:00 0.4 0.1 1.1 0.4 0.4 0 0.4 0.4 0.6 0.3 1.5 0.4 220 0 220 165 3.2 0 3.5 3 04/07/2006 08:40:00 0.4 0.1 1.1 0.4 0.4 0 0.4 0.4 0.5 0.2 1.5 0.4 221 3 229 165 3.4 0.1 3.8 3 04/07/2006 08:50:00 0.4 0.1 0.7 0.4 0.4 0 0.4 0.4 0.6 0.4 1.9 0.4 199 43 131 165 4.2 0.3 4.8 3.5 04/07/2006 09:00:00 0.4 0.2 1.5 0.4 0.4 0.2 1.1 0.4 0.7 0.4 1.9 0.4 131 32 136 165 5.1 0.2 5.5 4.3 04/07/2006 09:10:00 0.8 0.5 2.3 0.4 0.8 0.6 2.3 0.4 1.3 0.6 2.6 0.4 154 32 164 165 5.5 0.1 5.7 5 04/07/2006 09:20:00 0.9 0.6 3 0.4 0.9 0.6 3 0.4 1.3 0.6 3 0.4 156 15 159 165 5.2 0.1 5.7 5 04/07/2006 09:30:00 1.4 0.7 3 0.4 1.2 0.7 3 0.4 1.6 0.7 3.4 0.4 172 17 159 165 5.4 0.1 6.2 5 04/07/2006 09:40:00 1.9 0.8 3.4 0.4 1.5 0.8 3.4 0.4 2.1 0.6 3.4 0.4 147 17 144 165 5.3 0.1 5.7 5 04/07/2006 09:50:00 2.1 0.6 3.4 0.7 1.6 0.8 3.4 0.4 2.1 0.6 3.4 0.4 153 17 142 165 5.3 0 5.7 5 04/07/2006 10:00:00 2.2 0.6 3.4 0.4 1.8 0.7 3.4 0.4 2.5 0.6 4.2 0.7 157 12 165 165 5.2 0 5.5 5 04/07/2006 10:10:00 2.4 0.7 4.2 0.4 2 0.8 4.2 0.4 2.4 0.6 3.8 0.7 158 11 164 165 5.3 0 5.7 5.2 04/07/2006 10:20:00 2.4 0.6 3.8 1.1 2.1 0.6 3.4 0.4 2.5 0.5 3.8 1.1 143 13 164 165 5.2 0.1 5.7 5 04/07/2006 10:30:00 2.8 0.6 4.6 1.1 2.5 0.7 4.2 0.7 2.8 0.6 4.6 1.5 144 15 145 165 5.2 0.1 5.7 5 04/07/2006 10:40:00 3 0.5 4.2 1.5 2.8 0.5 4.2 1.5 3.1 0.5 4.2 1.5 144 12 170 165 5.6 0 6 5.2 04/07/2006 10:50:00 3.1 0.7 4.9 1.5 2.9 0.8 4.9 0.7 3.1 0.6 4.9 1.5 151 11 160 165 5.4 0.1 5.7 5.2 04/07/2006 11:00:00 3.1 0.8 5.3 1.5 3.1 0.8 5.3 1.5 3.3 0.7 6.1 1.9 149 12 148 165 5.4 0.1 6 5.2 04/07/2006 11:10:00 3.2 0.7 4.9 1.9 3.1 0.7 4.9 1.9 3.3 0.6 5.3 1.9 152 14 148 165 5.6 0 6 5.5 04/07/2006 11:20:00 3.1 0.7 4.6 1.1 3.1 0.7 4.9 0.7 3.2 0.7 4.6 1.5 141 15 151 165 5.6 0.1 6 5.5 04/07/2006 11:30:00 3.3 0.7 4.9 1.9 3.3 0.7 5.3 1.5 3.4 0.6 4.9 1.9 152 13 165 165 5.9 0 6.2 5.7 04/07/2006 11:40:00 3.2 0.7 4.9 1.9 3.2 0.7 4.9 1.9 3.2 0.6 4.6 1.5 151 13 153 165 5.7 0 6.2 5.5 04/07/2006 11:50:00 3.3 0.6 5.3 1.5 3.3 0.6 5.3 1.9 3.5 0.6 4.9 1.9 159 13 164 165 5.9 0.1 6.2 5.7 04/07/2006 12:00:00 3.7 0.8 6.5 1.9 3.7 0.8 6.5 1.9 3.7 0.8 6.1 1.9 159 9 156 165 5.7 0.1 6.2 5.2 04/07/2006 12:10:00 3.8 0.6 5.3 2.3 3.7 0.6 5.3 1.9 3.8 0.7 5.7 2.3 153 10 163 165 5.3 0.1 5.7 5 04/07/2006 12:20:00 3.2 0.6 4.6 1.1 3.2 0.6 4.9 1.9 3.3 0.6 4.6 1.9 153 9 154 165 5.4 0.1 5.7 5.2 04/07/2006 12:30:00 3.6 0.5 4.9 2.3 3.5 0.5 4.6 2.3 3.6 0.6 5.3 2.3 159 9 163 165 5.4 0 5.7 5.2 04/07/2006 12:40:00 3.5 0.6 5.7 1.1 3.4 0.6 5.7 1.1 3.6 0.6 5.3 2.3 154 11 173 165 5.5 0.1 5.7 5.2 04/07/2006 12:50:00 3.7 0.6 5.3 2.6 3.7 0.6 5.7 2.6 3.7 0.5 5.7 2.6 149 10 151 165 5.5 0.2 5.7 5.2 04/07/2006 13:00:00 3.5 0.7 6.5 1.9 3.5 0.7 6.1 1.9 3.6 0.7 6.1 1.9 150 10 133 165 5.5 0 5.7 5.2 04/07/2006 13:10:00 4.2 0.6 5.7 2.3 4.1 0.6 5.7 1.9 4.2 0.6 6.1 2.6 143 11 121 165 5.5 0 5.7 5.2 04/07/2006 13:20:00 4.4 0.6 5.7 2.6 4.4 0.6 6.1 2.6 4.5 0.6 5.7 3 144 11 121 165 5.3 0.1 5.5 5 04/07/2006 13:30:00 4.2 0.6 6.1 2.6 4.3 0.6 6.1 2.6 4.3 0.6 6.5 2.6 143 9 126 165 5.2 0 5.5 5 04/07/2006 13:40:00 4.2 0.7 6.1 2.3 4.2 0.7 6.1 2.3 4.2 0.6 5.7 2.6 141 15 153 165 5.3 0.1 5.7 5 04/07/2006 13:50:00 4.1 0.7 6.1 2.6 4.1 0.7 6.5 2.6 4.3 0.6 6.5 2.6 142 13 135 165 5.2 0 5.5 5 04/07/2006 14:00:00 4.1 0.7 6.1 1.9 4.1 0.7 6.5 1.9 4.1 0.7 6.1 2.6 137 11 158 165 5.2 0 5.5 5 04/07/2006 14:10:00 3.8 0.6 5.7 2.3 3.8 0.7 5.7 2.3 3.9 0.7 6.1 2.3 141 15 165 165 5.6 0.1 6 5.2 04/07/2006 14:20:00 3.9 0.7 5.7 2.3 3.9 0.7 5.7 2.3 3.8 0.7 5.3 1.9 148 13 165 165 5.7 0.1 6.2 5.5 04/07/2006 14:30:00 3.1 0.7 5.3 1.1 3.1 0.6 4.9 1.5 3.2 0.6 4.9 1.9 140 12 164 165 5.8 0.1 6.5 5.5 04/07/2006 14:40:00 3.2 0.6 4.6 1.9 3.3 0.6 4.9 1.9 3.4 0.6 5.7 1.9 145 11 136 165 5.9 0 6.2 5.7 04/07/2006 14:50:00 3.3 0.6 4.9 1.9 3.2 0.6 4.9 1.9 3.4 0.6 4.9 1.9 146 11 139 165 6.3 0 6.7 6 04/07/2006 15:00:00 3.2 0.6 4.9 2.3 3.2 0.6 4.9 2.3 3.3 0.7 5.3 1.9 141 12 134 165 6.2 0 6.5 6 04/07/2006 15:10:00 3.5 0.5 4.9 2.6 3.5 0.5 4.9 2.3 3.6 0.5 4.9 1.9 141 12 145 165 6.1 0 6.7 6 04/07/2006 15:20:00 3.2 0.6 4.9 1.9 3.2 0.6 4.9 1.9 3.3 0.6 5.3 1.5 145 11 131 165 6.1 0 6.7 5.7 04/07/2006 15:30:00 3.4 0.6 4.9 1.9 3.4 0.6 5.3 1.5 3.4 0.6 4.9 1.9 138 10 137 165 6.2 0.1 6.7 5.7 04/07/2006 15:40:00 3.7 0.5 5.3 2.3 3.7 0.5 4.9 2.3 3.6 0.6 5.3 2.3 138 12 143 165 6.1 0.1 6.2 5.7 04/07/2006 15:50:00 3.8 0.6 5.3 1.9 3.8 0.5 5.7 2.3 3.8 0.5 4.9 2.3 152 12 147 165 6.1 0 6.2 5.7 04/07/2006 16:00:00 3.8 0.6 5.3 1.1 3.8 0.6 5.3 1.1 4 0.5 5.3 2.6 146 12 148 165 6.2 0 6.7 6 04/07/2006 16:10:00 4.6 0.5 6.1 3.4 4.5 0.6 6.1 3.4 4.6 0.5 6.1 2.6 149 13 142 165 6 0 6.2 5.7 04/07/2006 16:20:00 4.5 0.6 6.1 3 4.4 0.6 5.7 3 4.6 0.5 5.7 3 161 10 165 165 6.1 0 6.2 5.7 04/07/2006 16:30:00 4.4 0.6 6.1 3 4.4 0.6 5.7 2.3 4.5 0.5 6.1 3 167 8 165 165 6.1 0 6.7 6 04/07/2006 16:40:00 4.9 0.7 7.2 2.6 4.8 0.7 7.6 2.6 5.1 0.8 6.8 3.4 173 9 168 165 6.2 0 6.7 6 04/07/2006 16:50:00 6.1 0.7 8 3.8 5.9 0.7 7.6 3.4 6.2 0.7 8 4.6 175 11 181 165 5.9 0.1 6.5 5.7 04/07/2006 17:00:00 5.7 0.6 7.2 3.8 5.6 0.6 7.2 3.4 5.9 0.6 7.6 4.2 179 7 174 165 5.8 0.1 6.2 5.7 04/07/2006 17:10:00 5.7 0.5 7.6 4.2 5.5 0.5 6.8 4.2 5.8 0.6 7.2 4.2 177 7 180 165 5.7 0 6 5.5 04/07/2006 17:20:00 6.2 0.5 7.6 4.6 6 0.5 7.6 4.6 6.5 0.6 8.4 4.6 172 6 173 165 5.4 0.2 5.7 5 04/07/2006 17:30:00 8 0.5 8.8 6.5 7.7 0.4 8.4 6.5 8.2 0.4 9.1 6.8 166 14 164 165 4.7 0.1 5 4.5 04/07/2006 17:40:00 8.2 0.4 9.1 6.8 7.9 0.4 8.8 6.8 8.5 0.4 9.5 7.2 170 7 169 165 4.6 0 4.8 4.5 04/07/2006 17:50:00 8.5 0.6 9.5 6.8 8.2 0.6 9.5 6.8 8.7 0.6 9.9 6.8 170 4 172 165 4.3 0.1 5 4.3 04/07/2006 18:00:00 7.6 0.4 8.8 6.5 7.4 0.4 8.4 6.5 7.7 0.5 8.8 6.1 171 5 175 165 4.4 0 4.5 4.3 04/07/2006 18:10:00 7.9 0.5 9.1 6.5 7.6 0.5 8.8 6.5 8 0.6 9.5 6.5 171 12 169 165 4.4 0 5 4.3 04/07/2006 18:20:00 8.3 0.6 9.5 6.5 8 0.5 9.5 6.5 8.5 0.7 9.9 6.8 170 5 176 165 4 0 4.3 3.8 04/07/2006 18:30:00 8.4 0.7 9.9 6.5 8.2 0.6 9.9 6.5 8.6 0.7 10.3 6.8 173 5 169 165 3.7 0 3.8 3.3 04/07/2006 18:40:00 8.6 0.7 9.9 6.1 8.3 0.6 9.5 6.1 8.7 0.7 10.7 6.8 176 5 176 165 3.7 0 3.8 3.5 04/07/2006 18:50:00 8.8 0.8 10.7 6.5 8.6 0.8 10.3 6.5 8.8 0.8 10.7 6.8 177 5 184 165 3.5 0.1 3.8 3 04/07/2006 19:00:00 9.3 0.6 10.7 7.2 8.9 0.5 10.3 7.2 9.4 0.6 10.7 7.6 171 5 180 165 3.3 0 3.5 3 04/07/2006 19:10:00 9 0.6 10.3 7.6 8.7 0.5 10.3 7.2 9.4 0.6 10.7 7.6 170 11 165 165 3.1 0 3.3 3 04/07/2006 19:20:00 8.6 0.6 10.3 7.2 8.3 0.6 9.9 6.8 8.8 0.6 9.9 7.2 172 6 168 165 3 0 3.3 2.8 04/07/2006 19:30:00 8.3 0.4 9.5 6.8 8 0.4 8.8 6.5 8.4 0.5 9.5 6.8 170 4 166 165 2.8 0 3 2.6 04/07/2006 19:40:00 9.4 0.6 10.7 7.6 9.1 0.6 10.3 7.2 9.7 0.6 10.7 7.6 168 3 173 165 2.6 0.1 3 2.3 04/07/2006 19:50:00 9.5 0.6 10.7 8 9.2 0.5 10.3 7.6 9.7 0.6 11.1 7.6 170 6 251 165 2.5 0.1 2.8 2.1 04/07/2006 20:00:00 9.2 0.5 10.3 7.6 8.8 0.5 9.9 7.6 9.2 0.5 10.3 7.2 175 8 174 165 2.6 0 2.8 2.3 04/07/2006 20:10:00 9 0.6 10.3 7.2 8.7 0.6 9.9 7.2 9.3 0.7 10.7 7.6 171 4 173 165 2.6 0 2.8 2.3 04/07/2006 20:20:00 9 0.5 10.7 8 8.6 0.4 10.3 7.2 9.2 0.5 10.3 7.6 168 4 165 165 2.5 0 2.6 2.3 04/07/2006 20:30:00 8.8 0.6 10.3 7.2 8.4 0.5 9.9 6.8 8.9 0.6 10.3 7.6 171 6 165 165 2.5 0 2.8 2.3 04/07/2006 20:40:00 8.5 0.8 11.1 6.1 8.2 0.7 10.3 6.5 8.6 0.8 10.3 6.5 173 13 184 165 2.5 0.1 2.8 2.1 04/07/2006 20:50:00 9.1 0.6 10.7 7.2 8.7 0.5 10.3 6.8 9.2 0.6 10.7 8 172 7 169 165 2.4 0.2 2.6 1.8 04/07/2006 21:00:00 9.3 0.8 11.1 6.8 9 0.8 10.7 6.5 9.6 0.8 11.8 7.6 174 5 173 165 2.5 0 2.8 1.8 04/07/2006 21:10:00 7.3 0.9 9.9 5.3 7.1 0.8 9.9 5.3 7.6 0.9 10.3 5.3 179 7 174 165 2.4 0 2.8 2.3 04/07/2006 21:20:00 7.2 0.7 9.1 4.9 7 0.7 8.8 4.9 7.4 0.8 9.5 5.3 176 7 176 165 2.4 0 2.6 2.1 04/07/2006 21:30:00 7.6 0.7 9.5 5.7 7.3 0.7 9.1 5.7 7.6 0.7 9.1 5.7 179 6 182 165 2.4 0 2.6 2.1 04/07/2006 21:40:00 7.2 0.7 8.8 5.3 7.1 0.6 8.8 5.7 7.4 0.7 9.1 5.3 181 7 172 165 2.3 0 2.6 1.8 04/07/2006 21:50:00 6.9 0.7 8.4 4.9 6.7 0.6 8 4.6 7 0.7 8.8 5.3 179 7 181 165 2.2 0 2.6 1.6 04/07/2006 22:00:00 7.4 0.9 9.9 5.3 7.2 0.8 9.1 4.9 7.6 0.9 9.5 5.3 180 9 184 165 2.2 0 2.6 1.6 04/07/2006 22:10:00 7.7 0.8 10.3 6.1 7.5 0.8 9.9 5.7 7.8 0.8 9.9 5.7 179 8 182 165 2.1 0 2.3 1.8 04/07/2006 22:20:00 8.1 0.8 9.9 6.5 7.8 0.7 9.5 6.1 8.3 0.7 9.9 6.5 172 13 173 165 2 0.1 2.3 1.6 04/07/2006 22:30:00 9.4 0.9 11.5 7.2 9.1 0.8 11.1 6.8 9.6 0.9 11.8 7.2 174 8 183 165 2 0.1 2.3 1.6 04/07/2006 22:40:00 9.4 0.9 11.1 6.5 9.1 0.9 10.7 6.1 9.7 0.9 11.5 7.2 175 11 181 165 1.9 0.1 2.3 1.6 04/07/2006 22:50:00 10.2 1 12.6 7.2 10 0.9 12.2 7.6 10.5 0.9 13 7.6 181 6 181 165 2 0.1 2.3 1.6 04/07/2006 23:00:00 8.5 0.8 11.1 6.1 8.4 0.8 10.7 6.1 8.7 0.9 10.7 6.1 185 9 183 165 2 0.1 2.3 1.6 04/07/2006 23:10:00 9.3 1.2 11.8 6.1 9.1 1.1 11.8 6.1 9.4 1.2 11.8 6.1 185 7 181 165 2.1 0 2.3 1.8 04/07/2006 23:20:00 9 1 11.5 6.1 8.8 1 11.1 6.1 9.1 1 11.8 6.5 185 8 176 165 2.1 0 2.3 1.8 04/07/2006 23:30:00 8.9 1 11.5 6.5 8.6 1 11.1 6.1 9.1 1 12.2 6.8 171 13 185 165 2.1 0 2.3 1.8 04/07/2006 23:40:00 9.7 1 12.2 7.6 9.4 0.9 11.5 7.2 9.9 1 11.8 7.2 167 5 172 165 2 0 2.3 1.8 04/07/2006 23:50:00 10 1 12.6 8 9.7 0.9 12.2 8 10.2 1 13.3 7.6 168 10 178 165 2 0 2.3 1.6 04/08/2006 00:00:00 10.2 1.1 13.3 8 10.1 1.1 13.3 7.6 10.2 1.1 13.3 7.6 181 9 184 165 2.1 0.1 2.3 1.6 04/08/2006 00:10:00 10.7 1 13.3 8.8 10.4 1 12.6 8.4 10.8 1 13.7 8 177 7 177 165 2.1 0.1 2.3 1.6 04/08/2006 00:20:00 10.9 1.2 14.5 8 10.8 1.1 14.1 8 11.2 1.2 14.1 8.4 186 7 189 165 2.1 0.1 2.3 1.6 04/08/2006 00:30:00 11.1 1.3 14.5 8 11 1.2 14.1 8 11.2 1.3 14.5 8 186 7 196 165 2.1 0.2 2.6 1.6 04/08/2006 00:40:00 10.9 1.1 14.5 8 10.8 1.1 13.7 8 11 1.1 13.3 8 184 8 176 165 2.3 0 2.6 1.8 04/08/2006 00:50:00 11.6 0.9 14.5 8.8 11.5 0.9 14.9 8.8 11.9 1.1 14.1 8.8 185 5 195 165 2.3 0 2.6 1.8 04/08/2006 01:00:00 10.2 1 12.2 7.6 10.1 0.9 11.8 7.6 10.3 1 12.6 8 186 5 188 165 2.3 0 2.6 1.8 04/08/2006 01:10:00 8.9 0.7 11.1 7.2 8.5 0.7 10.7 6.8 8.9 0.7 11.1 7.2 178 6 184 165 2.3 0 2.6 1.8 04/08/2006 01:20:00 8.5 0.8 10.7 5.7 8.4 0.8 10.3 5.3 8.6 0.8 10.3 6.8 186 6 189 165 2.3 0 2.6 1.8 04/08/2006 01:30:00 8.9 0.7 10.7 7.2 8.7 0.7 10.7 7.2 9.1 0.8 11.1 7.2 185 7 182 165 2.4 0 2.6 2.3 04/08/2006 01:40:00 8.1 0.9 10.3 6.1 8 0.9 10.3 6.1 8.3 0.9 10.7 6.1 185 8 198 165 2.4 0 2.6 1.8 04/08/2006 01:50:00 7.7 0.7 9.9 5.7 7.6 0.7 9.5 5.7 7.8 0.7 9.9 6.1 176 7 181 165 2.4 0 2.6 2.1 04/08/2006 02:00:00 8.5 1 11.1 6.1 8.4 1 10.7 6.1 8.7 1.1 11.5 6.1 184 7 189 165 2.4 0 2.8 2.3 04/08/2006 02:10:00 8.8 0.8 10.7 6.8 8.7 0.8 10.3 6.8 9 0.8 10.7 7.2 181 5 183 165 2.5 0 2.8 2.3 04/08/2006 02:20:00 8.3 0.8 10.3 6.5 8.2 0.7 10.3 6.1 8.6 0.8 11.1 6.8 178 8 183 165 2.4 0 2.6 2.3 04/08/2006 02:30:00 9 0.8 10.7 6.8 8.8 0.7 10.3 6.5 9.2 0.8 10.7 7.2 182 5 185 165 2.5 0 2.8 2.3 04/08/2006 02:40:00 8.4 0.8 10.3 6.5 8.2 0.8 9.9 6.5 8.6 0.9 10.7 6.1 178 6 184 165 2.6 0 2.8 2.6 04/08/2006 02:50:00 9.5 0.6 10.7 6.8 9.2 0.5 10.3 6.8 9.8 0.6 11.1 8 175 4 165 165 2.5 0 2.6 2.6 04/08/2006 03:00:00 10 0.5 11.1 8.4 9.7 0.5 10.7 8.4 10.3 0.5 11.5 9.1 171 3 176 165 2.4 0 2.8 2.3 04/08/2006 03:10:00 9.9 0.4 10.7 8.8 9.5 0.3 10.3 8.4 10.1 0.5 11.1 8.4 171 3 166 165 2.4 0 2.6 2.3 04/08/2006 03:20:00 9.6 0.8 11.5 7.6 9.4 0.8 11.1 7.2 9.8 0.8 11.8 7.6 172 5 173 165 2.4 0 2.6 2.3 04/08/2006 03:30:00 9.5 0.6 10.7 7.6 9.2 0.6 10.3 7.2 9.7 0.7 11.1 8 175 5 179 165 2.5 0 2.6 2.3 04/08/2006 03:40:00 9.5 0.4 10.7 8 9.2 0.4 10.3 8 9.7 0.5 10.7 8.4 170 8 173 165 2.4 0 2.6 2.3 04/08/2006 03:50:00 10.3 0.8 12.2 9.1 10 0.7 11.8 8.8 10.5 0.8 13 8.8 167 13 165 165 2.4 0 2.6 2.3 04/08/2006 04:00:00 13.2 0.5 14.5 11.1 12.8 0.5 14.1 11.1 13.6 0.6 14.9 10.7 165 13 173 165 2.4 0 2.6 2.3 04/08/2006 04:10:00 13.8 0.9 15.6 11.8 13.4 0.8 15.3 11.5 14.1 1 16.1 11.5 168 10 168 165 2.4 0 2.6 1.8 04/08/2006 04:20:00 13.9 0.8 15.6 11.5 13.5 0.7 14.9 11.1 14.1 0.8 16.1 11.8 167 4 166 165 2.4 0 2.6 1.8 04/08/2006 04:30:00 14.1 0.8 16.4 11.8 13.7 0.8 16.1 11.8 14.5 0.8 16.4 11.8 167 3 167 165 2.4 0 2.6 1.8 04/08/2006 04:40:00 13.5 0.8 15.3 11.1 13.2 0.7 14.9 11.1 13.7 0.8 15.3 11.8 167 5 162 165 2.3 0 2.6 2.1 04/08/2006 04:50:00 13.6 0.7 15.6 11.1 13.2 0.7 14.9 11.5 13.9 0.8 16.1 11.5 168 15 165 165 2.3 0 2.6 1.8 04/08/2006 05:00:00 13.6 0.7 15.3 11.5 13.2 0.7 14.9 11.1 13.9 0.8 15.6 11.5 167 13 172 165 2.3 0 2.8 2.1 04/08/2006 05:10:00 13.4 0.6 14.9 11.8 12.9 0.5 14.5 11.1 13.7 0.7 14.9 11.5 168 11 167 165 2.3 0 2.6 1.8 04/08/2006 05:20:00 12.2 0.7 14.1 9.9 11.8 0.6 13.3 9.9 12.4 1 14.5 9.9 169 9 165 165 2.3 0 2.6 2.3 04/08/2006 05:30:00 12 0.6 13.7 9.9 11.7 0.6 13.3 9.9 12.2 0.7 14.1 10.3 166 16 165 165 2.3 0 2.6 2.3 04/08/2006 05:40:00 12.4 0.8 14.9 9.9 12.1 0.8 14.1 9.9 12.6 0.9 15.3 9.9 166 9 165 165 2.2 0 2.3 2.1 04/08/2006 05:50:00 12.6 0.8 14.5 10.3 12.3 0.7 14.1 10.3 12.7 0.9 14.5 9.9 167 13 169 165 2 0 2.3 1.8 04/08/2006 06:00:00 12.8 0.6 14.5 10.7 12.5 0.6 14.1 10.7 13.1 0.7 15.3 10.7 167 9 165 165 2 0 2.3 1.8 04/08/2006 06:10:00 13.2 0.8 14.9 11.1 12.8 0.7 14.1 10.7 13.5 0.8 15.3 10.7 169 7 174 165 2 0 2.3 1.8 04/08/2006 06:20:00 12.6 0.8 14.5 10.3 12.2 0.7 13.7 10.3 12.8 0.9 14.5 10.3 171 4 173 165 2 0 2.3 1.8 04/08/2006 06:30:00 13.3 0.7 14.5 11.1 12.9 0.6 14.1 11.1 13.5 0.7 14.9 11.5 172 9 178 165 1.9 0 2.1 1.8 04/08/2006 06:40:00 13.3 0.8 15.3 11.5 12.9 0.7 14.9 10.7 13.5 0.9 15.6 9.9 174 4 179 165 1.9 0 2.1 1.8 04/08/2006 06:50:00 12.2 0.6 13.7 10.7 11.8 0.6 13.3 9.9 12.5 0.7 14.1 10.7 172 4 172 165 1.9 0 2.1 1.8 04/08/2006 07:00:00 11.1 0.7 13 8.8 10.7 0.7 12.2 8 11.4 0.8 13 9.1 174 5 172 165 1.8 0 1.8 1.6 04/08/2006 07:10:00 10 0.5 11.8 8.4 9.7 0.5 11.1 8 10.2 0.5 11.8 8.8 173 5 173 165 1.7 0 1.8 1.6 04/08/2006 07:20:00 9.4 0.6 10.7 7.2 9.2 0.6 10.7 7.2 9.6 0.7 11.1 7.6 170 15 171 165 1.7 0 1.8 1.6 04/08/2006 07:30:00 8 0.7 9.9 6.5 7.8 0.6 9.5 6.1 8 0.9 10.3 6.1 166 8 165 165 1.7 0 1.8 1.6 04/08/2006 07:40:00 7.6 0.3 8 6.5 7.3 0.3 8 6.1 7.8 0.4 8.8 6.5 167 10 172 165 1.6 0 1.8 1.6 04/08/2006 07:50:00 7.4 0.3 8 6.5 7.2 0.3 7.6 6.5 7.6 0.4 8.4 6.1 163 7 165 165 1.6 0 1.8 1.4 04/08/2006 08:00:00 6.7 0.4 7.6 5.7 6.6 0.4 7.6 5.7 6.9 0.5 8 5.3 161 3 162 165 1.5 0 1.6 1.4 04/08/2006 08:10:00 6.2 0.4 6.8 4.9 6.1 0.3 6.8 4.9 6.4 0.4 7.2 4.9 152 4 152 165 1.5 0 1.6 1.4 04/08/2006 08:20:00 6.7 0.5 8 5.7 6.6 0.5 8 5.3 6.8 0.5 8 5.3 153 5 143 165 1.5 0 1.6 1.4 04/08/2006 08:30:00 6.6 0.4 7.6 5.3 6.6 0.4 8 5.3 6.7 0.4 8 5.7 154 3 156 165 1.7 0 1.8 1.4 04/08/2006 08:40:00 6.7 0.4 7.6 5.3 6.7 0.4 7.6 5.7 6.8 0.5 7.6 5.3 150 4 150 165 1.7 0 1.8 1.6 04/08/2006 08:50:00 6.3 0.3 7.2 5.7 6.2 0.3 7.2 5.7 6.5 0.4 7.6 5.3 152 4 150 165 1.7 0 1.8 1.6 04/08/2006 09:00:00 6.4 0.4 7.2 5.3 6.4 0.4 7.2 4.9 6.6 0.4 7.6 5.3 152 6 160 165 1.7 0 1.8 1.6 04/08/2006 09:10:00 7.3 0.4 8.4 6.1 7.2 0.4 8.4 6.1 7.4 0.5 8.4 5.3 149 3 148 165 1.7 0 1.8 1.6 04/08/2006 09:20:00 7.1 0.4 8 5.7 7 0.4 8 5.7 7.2 0.5 8.4 5.7 150 3 151 165 1.7 0 1.8 1.6 04/08/2006 09:30:00 7.3 0.4 8 6.1 7.3 0.4 8 6.1 7.5 0.4 8.8 6.1 150 1 151 165 1.6 0 1.8 1.4 04/08/2006 09:40:00 6.9 0.4 7.6 5.7 6.9 0.4 8 5.7 7 0.5 8 5.7 151 0 151 165 1.5 0 1.6 1.4 04/08/2006 09:50:00 6.7 0.3 7.2 6.1 6.6 0.3 7.6 5.7 6.9 0.3 7.6 5.7 151 0 151 165 1.5 0 1.6 1.4 04/08/2006 10:00:00 5.9 0.4 6.8 4.9 5.8 0.4 6.8 4.9 6.1 0.4 6.8 4.9 151 0 151 165 1.6 0 1.6 1.4 04/08/2006 10:10:00 5.7 0.4 6.5 4.9 5.5 0.3 6.5 4.6 5.9 0.4 6.8 4.6 151 0 151 165 1.5 0 1.6 1.4 04/08/2006 10:20:00 4.9 0.5 6.1 3.8 4.8 0.5 5.7 3.8 5.2 0.5 6.5 4.2 151 0 152 165 1.4 0 1.6 1.4 04/08/2006 10:30:00 4.9 0.4 5.7 3.8 4.7 0.4 5.7 3.8 5.1 0.4 5.7 4.2 151 0 151 165 1.4 0 1.6 1.4 04/08/2006 10:40:00 4.8 0.4 5.7 3.8 4.7 0.4 5.7 3.8 5 0.4 6.1 3.8 151 0 151 165 1.4 0 1.6 1.4 04/08/2006 10:50:00 4.2 0.2 4.6 3.8 4.1 0.2 4.6 3.4 4.5 0.2 4.9 4.2 151 0 151 165 1.4 0 1.6 1.4 04/08/2006 11:00:00 4.5 0.3 5.3 3.8 4.4 0.3 5.3 3.8 4.8 0.3 5.3 3.8 151 0 151 165 1.3 0 1.4 1.4 04/08/2006 11:10:00 4.3 0.4 5.3 3 4.2 0.4 5.3 3 4.7 0.4 5.7 3.4 151 0 151 165 1.3 0 1.4 1.4 04/08/2006 11:20:00 3 0.4 3.8 1.9 2.9 0.4 3.8 1.9 3.4 0.4 4.2 2.3 151 0 151 165 1.4 0 1.6 1.4 04/08/2006 11:30:00 2.3 0.4 3 1.1 2.3 0.4 3 1.1 2.8 0.4 3.4 1.9 151 0 151 165 1.4 0 1.6 1.4 04/08/2006 11:40:00 0.6 0.5 1.9 0.4 0.6 0.5 1.9 0.4 1.3 0.7 2.3 0.4 151 0 151 165 1.4 0 1.6 1.4 04/08/2006 11:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 151 0 165 165 1.6 0 1.8 1.4 04/08/2006 12:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 151 0 165 165 1.7 0 1.8 1.6 04/08/2006 12:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 151 0 165 165 1.8 0 1.8 1.6 04/08/2006 12:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 151 0 165 165 1.9 0 2.1 1.8 04/08/2006 12:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 151 0 165 165 2.2 0.1 2.6 1.8 04/08/2006 12:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 151 0 165 165 2.4 0 2.6 2.3 04/08/2006 12:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 151 0 165 165 2.5 0 2.8 2.3 04/08/2006 13:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 151 0 165 165 2.4 0 3 2.3 04/08/2006 13:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 151 0 165 165 2.1 0 2.3 1.8 04/08/2006 13:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 151 0 165 165 2.1 0.2 2.6 1.4 04/08/2006 13:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.7 0.4 151 0 165 165 2.6 0 2.8 1.8 04/08/2006 13:40:00 0.4 0.3 1.5 0.4 0.4 0 0.4 0.4 0.9 0.5 1.9 0.4 183 13 195 165 2.4 0.1 2.8 1.8 04/08/2006 13:50:00 1.3 0.2 1.9 0.7 0.4 0 0.4 0.4 1.6 0.2 1.9 1.1 204 8 216 165 2.2 0 2.3 1.8 04/08/2006 14:00:00 2 0.3 3 1.5 1.7 0.6 3 0.4 2.1 0.2 2.6 1.5 232 6 242 165 2.1 0 2.3 1.8 04/08/2006 14:10:00 2.8 0.2 3 2.3 3.1 0.2 3.4 2.6 3.1 0.3 3.8 2.3 233 3 242 165 2.2 0 2.3 1.8 04/08/2006 14:20:00 3.1 0.2 3.4 2.6 3.5 0.3 4.2 3 3.3 0.2 3.8 2.6 230 0 231 165 2.2 0 2.3 2.1 04/08/2006 14:30:00 2.1 0.8 3.4 0.4 2.6 0.6 3.8 1.5 2.7 0.5 3.8 1.9 245 16 231 165 2.2 0 2.3 2.1 04/08/2006 14:40:00 1.1 0.5 1.9 0.4 2 0.3 2.6 1.1 2 0.4 2.6 1.1 276 7 282 165 2.5 0 2.8 2.3 04/08/2006 14:50:00 0.4 0.2 1.1 0.4 1 0.6 2.3 0.4 1.2 0.6 2.6 0.4 282 9 269 165 2.9 0.1 3.3 2.3 04/08/2006 15:00:00 1.3 0.6 2.6 0.4 1.8 0.5 2.6 0.4 1.8 0.5 2.6 0.4 288 11 297 165 3.1 0 3.5 2.8 04/08/2006 15:10:00 1.6 0.7 2.6 0.4 1.5 0.7 2.6 0.4 1.8 0.5 2.6 0.7 311 8 308 165 3.6 0.2 4.3 3.3 04/08/2006 15:20:00 2 0.8 4.2 0.4 1.9 0.8 4.2 0.4 2.1 0.6 3.8 0.7 316 13 300 165 4 0 4.3 3.5 04/08/2006 15:30:00 3.1 0.8 5.7 0.7 3 0.9 5.7 0.4 3 0.6 4.9 1.5 322 14 333 165 3.7 0.1 4 3.3 04/08/2006 15:40:00 3 0.6 4.6 0.7 2.9 0.5 4.2 1.1 2.9 0.5 4.2 1.1 324 17 340 165 3.3 0 3.5 2.6 04/08/2006 15:50:00 2.5 0.9 4.2 0.4 2.1 0.9 4.2 0.4 2.8 0.8 3.8 0.7 330 33 343 165 3.2 0 3.5 2.8 04/08/2006 16:00:00 4.1 1.3 6.8 0.4 4.3 1.2 6.8 0.7 4.1 1 6.5 1.1 269 21 279 165 3 0 3.3 2.8 04/08/2006 16:10:00 2.5 1.2 5.7 0.4 2.7 1.2 5.7 0.7 2.5 0.9 5.7 1.1 274 22 290 165 3.4 0.2 3.8 2.8 04/08/2006 16:20:00 1.2 0.8 3 0.4 1.2 0.8 3 0.4 1.4 0.8 3.4 0.4 217 39 239 165 3.3 0.2 3.5 2.8 04/08/2006 16:30:00 1.1 0.6 2.6 0.4 1 0.6 2.6 0.4 1.6 0.5 3 0.4 194 22 229 165 3.4 0.1 3.8 3 04/08/2006 16:40:00 0.7 0.4 1.9 0.4 0.6 0.4 1.9 0.4 0.9 0.7 2.6 0.4 177 45 142 165 3.4 0.4 4.5 2.8 04/08/2006 16:50:00 1.6 0.8 3 0.4 1.6 0.8 3 0.4 1.5 0.6 3 0.4 278 18 286 165 4.7 0.2 5 4 04/08/2006 17:00:00 1.5 0.5 2.6 0.4 2 0.6 3.4 0.4 2.1 0.5 3 0.7 257 14 256 165 4.6 0.1 5 4.3 04/08/2006 17:10:00 1.1 0.4 1.9 0.4 0.7 0.4 2.3 0.4 1.5 0.4 2.3 0.4 190 35 245 165 4.7 0.3 5.2 4 04/08/2006 17:20:00 1.4 0.3 2.3 0.7 0.7 0.4 1.9 0.4 1.3 0.3 2.3 0.7 188 17 172 165 4.3 0.1 4.8 4 04/08/2006 17:30:00 1.6 0.4 2.6 0.4 0.8 0.5 2.3 0.4 1.5 0.5 2.3 0.4 176 20 178 165 4.5 0 4.8 4.3 04/08/2006 17:40:00 1.3 0.5 2.3 0.4 0.6 0.3 1.5 0.4 1.3 0.5 2.3 0.4 168 5 167 165 4.1 0.1 4.5 3.5 04/08/2006 17:50:00 0.9 0.4 1.5 0.4 0.4 0 0.4 0.4 0.9 0.4 1.9 0.4 174 9 170 165 4.6 0.3 5.2 4 04/08/2006 18:00:00 0.8 0.4 1.5 0.4 0.4 0 0.4 0.4 0.8 0.4 1.9 0.4 172 3 173 165 5.1 0 5.5 4.8 04/08/2006 18:10:00 1 0.4 1.9 0.4 0.4 0 0.4 0.4 0.9 0.3 1.5 0.4 184 11 173 165 4.9 0.1 5.2 4.8 04/08/2006 18:20:00 0.6 0.3 1.5 0.4 0.4 0 0.4 0.4 0.5 0.2 1.1 0.4 178 14 165 165 5.2 0 5.5 4.8 04/08/2006 18:30:00 0.4 0 0.7 0.4 0.4 0 0.4 0.4 0.4 0 0.7 0.4 167 14 323 165 5.4 0.1 5.7 5 04/08/2006 18:40:00 0.4 0.1 1.1 0.4 0.4 0 0.4 0.4 0.4 0.1 1.1 0.4 324 1 325 165 4.9 0.4 5.7 4.3 04/08/2006 18:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.7 0.4 325 0 165 165 4.8 0.2 5.2 4.3 04/08/2006 19:00:00 0.4 0.1 0.7 0.4 0.4 0 0.4 0.4 0.4 0.2 1.1 0.4 325 0 325 165 4.2 0 4.5 4.3 04/08/2006 19:10:00 0.4 0.1 1.1 0.4 0.4 0 0.4 0.4 0.5 0.2 1.1 0.4 325 0 325 165 4.3 0 4.5 4.3 04/08/2006 19:20:00 0.4 0.1 0.7 0.4 0.4 0 0.4 0.4 0.5 0.2 1.1 0.4 325 0 325 165 4.3 0.1 4.5 3.8 04/08/2006 19:30:00 0.6 0.3 1.5 0.4 0.4 0 0.4 0.4 0.8 0.4 1.5 0.4 325 0 325 165 3.7 0.3 4.8 2.8 04/08/2006 19:40:00 1.4 0.6 2.3 0.4 0.9 0.5 1.9 0.4 1.5 0.6 2.3 0.4 344 14 351 165 2.8 0.2 3.5 2.3 04/08/2006 19:50:00 2.1 0.4 3 1.5 1.8 0.7 3 0.4 2.2 0.4 3 1.5 357 12 342 165 2.4 0.1 2.6 1.8 04/08/2006 20:00:00 1.7 0.8 3.4 0.4 1.6 0.9 3.8 0.4 1.8 0.8 3.8 0.4 331 4 333 165 2.3 0 2.6 1.8 04/08/2006 20:10:00 1.8 0.6 3.4 0.7 1.8 0.7 3.4 0.4 1.8 0.6 3.4 0.7 327 10 323 165 2.3 0 2.6 2.1 04/08/2006 20:20:00 1.6 0.6 2.6 0.4 1.6 0.6 2.6 0.4 1.5 0.5 2.3 0.4 319 6 313 165 2.3 0 2.6 2.1 04/08/2006 20:30:00 2.4 0.4 3.8 1.5 2.5 0.4 3.8 1.1 2 0.4 3 0.7 302 9 299 165 2.6 0 2.8 2.3 04/08/2006 20:40:00 3.4 0.5 4.9 2.3 3.5 0.5 4.9 2.3 2.5 0.4 3.8 1.5 302 4 301 165 2.7 0 2.8 2.6 04/08/2006 20:50:00 4.4 0.4 5.3 3.4 4.5 0.4 5.3 3.4 3.3 0.5 4.9 2.3 300 4 304 165 2.7 0.1 3 2.3 04/08/2006 21:00:00 3.9 0.3 4.9 3 4 0.3 4.9 3.4 3 0.4 4.2 2.3 301 4 299 165 3 0 3.3 2.8 04/08/2006 21:10:00 3.7 0.3 4.6 3 3.8 0.3 4.6 3 3.1 0.4 4.2 2.3 297 4 306 165 2.9 0 3 2.8 04/08/2006 21:20:00 3.6 0.2 4.2 3 3.8 0.3 4.6 3 3.6 0.4 4.6 2.3 288 5 294 165 2.9 0 3 2.8 04/08/2006 21:30:00 3.4 0.3 4.2 2.6 3.5 0.3 4.2 3 3.6 0.3 4.2 2.6 277 2 279 165 2.7 0 2.8 2.6 04/08/2006 21:40:00 2.6 0.5 3.4 1.1 3 0.2 3.8 2.6 3 0.3 3.4 2.3 273 6 276 165 2.7 0 2.8 2.6 04/08/2006 21:50:00 1.6 0.6 3 0.4 1.5 0.7 3 0.4 1.7 0.5 3 0.7 196 35 252 165 2.5 0.1 2.8 2.3 04/08/2006 22:00:00 1.8 0.3 2.3 0.7 1.6 0.4 2.3 0.7 1.9 0.3 2.6 1.1 151 7 150 165 2.5 0.1 2.8 2.3 04/08/2006 22:10:00 1.5 0.7 2.6 0.4 1.3 0.7 2.6 0.4 1.7 0.6 3 0.7 166 5 172 165 2.4 0.1 2.8 2.3 04/08/2006 22:20:00 1.8 0.5 3 1.1 1.7 0.6 3.4 0.7 2 0.5 3 1.1 183 17 206 165 2.4 0 2.8 2.3 04/08/2006 22:30:00 2.9 0.3 3.8 2.3 3.2 0.3 4.2 2.3 3.2 0.3 4.2 2.6 226 6 228 165 2.7 0.1 3 2.3 04/08/2006 22:40:00 2 0.7 4.6 0.4 2.3 0.6 4.6 1.1 2.4 0.6 4.9 1.1 223 14 233 165 3 0 3.3 2.8 04/08/2006 22:50:00 1.8 0.5 3 0.4 2.1 0.5 3.4 0.7 2.2 0.4 3 1.5 218 11 244 165 2.9 0 3 2.6 04/08/2006 23:00:00 2.7 0.7 4.2 1.1 3.1 0.8 5.3 1.5 3.1 0.6 4.6 1.5 238 13 244 165 2.7 0 3 2.6 04/08/2006 23:10:00 3.1 0.5 4.6 1.5 3.4 0.5 4.9 2.3 3.3 0.4 4.6 2.3 245 8 254 165 3.2 0.1 3.5 2.8 04/08/2006 23:20:00 2.5 0.6 4.2 0.7 3 0.5 4.6 1.9 3 0.4 4.2 1.9 268 14 261 165 3.6 0 3.8 3.3 04/08/2006 23:30:00 2.6 0.6 3.8 1.1 3 0.6 4.2 1.9 3 0.5 4.2 1.9 279 6 277 165 3.5 0 3.8 3.3 04/08/2006 23:40:00 3 0.7 4.2 1.1 3.4 0.6 4.6 1.5 3.3 0.5 4.6 1.9 262 30 285 165 3.1 0.1 3.3 2.6 04/08/2006 23:50:00 3 0.7 4.2 1.5 3 0.6 4.2 1.5 3.4 0.7 4.6 1.9 188 6 187 165 2.3 0.1 2.6 2.1 04/09/2006 00:00:00 3.1 0.5 4.2 2.3 3 0.5 4.2 1.9 3.4 0.5 4.2 2.6 189 5 184 165 2.5 0 2.8 2.3 04/09/2006 00:10:00 2.9 0.3 3.4 2.3 2.8 0.3 3.4 2.3 3.1 0.3 3.8 2.6 182 3 180 165 2.4 0 2.6 2.3 04/09/2006 00:20:00 1.6 0.9 3 0.4 1.5 0.9 2.6 0.4 1.8 1 3.4 0.4 176 6 177 165 2.7 0 2.8 2.3 04/09/2006 00:30:00 0.8 0.5 1.9 0.4 0.7 0.4 1.5 0.4 0.9 0.5 1.9 0.4 181 13 164 165 2.7 0 2.8 2.6 04/09/2006 00:40:00 0.8 0.4 1.5 0.4 0.7 0.4 1.5 0.4 1.2 0.4 1.9 0.4 169 7 157 165 2.8 0 3 2.6 04/09/2006 00:50:00 0.5 0.2 1.1 0.4 0.4 0.1 1.1 0.4 0.9 0.3 1.9 0.4 172 2 172 165 2.9 0.1 3 2.6 04/09/2006 01:00:00 0.5 0.3 1.5 0.4 0.5 0.3 1.1 0.4 1.3 0.3 1.9 0.4 176 11 165 165 3.2 0.1 3.5 2.8 04/09/2006 01:10:00 0.5 0.3 1.5 0.4 0.6 0.3 1.5 0.4 1.4 0.2 1.9 0.7 195 11 203 165 3.5 0 3.5 3.3 04/09/2006 01:20:00 1.8 0.4 2.3 0.7 1.8 0.4 2.6 0.7 2 0.4 3 1.1 193 1 193 165 3.3 0.1 3.5 3 04/09/2006 01:30:00 2 0.3 2.6 1.5 2.1 0.2 2.6 1.5 2.5 0.2 3 1.9 201 5 196 165 3.3 0.2 3.5 2.8 04/09/2006 01:40:00 1.5 0.5 2.3 0.4 1.6 0.5 2.3 0.4 1.9 0.6 2.6 0.4 206 9 211 165 3.5 0 3.8 3.3 04/09/2006 01:50:00 1.7 0.3 1.9 0.7 1.8 0.2 2.3 1.1 2.2 0.3 2.6 1.5 210 5 205 165 3.8 0 4 3.5 04/09/2006 02:00:00 0.5 0.3 1.5 0.4 0.5 0.4 1.5 0.4 0.6 0.4 1.9 0.4 265 28 238 165 3.5 0.2 4 3 04/09/2006 02:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0.2 1.1 0.4 208 18 165 165 3.1 0 3.3 2.8 04/09/2006 02:20:00 0.4 0.1 1.1 0.4 0.4 0.1 1.1 0.4 0.7 0.3 1.5 0.4 186 8 192 165 3.3 0 3.5 3 04/09/2006 02:30:00 1.7 0.6 2.6 0.4 1.7 0.7 3 0.4 1.9 0.5 3 1.1 184 9 192 165 3.5 0.1 4 3.3 04/09/2006 02:40:00 1.7 0.4 2.6 0.7 1.9 0.4 3 1.1 2.1 0.3 3 1.1 201 3 199 165 4 0 4.3 3.8 04/09/2006 02:50:00 1.2 0.5 2.3 0.4 1.3 0.6 2.6 0.4 1.7 0.5 2.6 0.7 206 5 208 165 3.8 0 4.3 3.5 04/09/2006 03:00:00 1.5 0.5 2.6 0.4 1.5 0.5 3 0.4 1.6 0.3 2.3 0.7 211 13 215 165 3.6 0 3.8 3.5 04/09/2006 03:10:00 1.1 0.4 1.9 0.4 1 0.4 1.9 0.4 1.5 0.4 2.3 0.7 192 23 209 165 3.8 0.1 4 3.5 04/09/2006 03:20:00 1.3 0.3 1.9 0.7 1.2 0.3 1.9 0.4 1.4 0.4 2.3 0.4 187 17 204 165 3.3 0 3.5 3 04/09/2006 03:30:00 1.5 0.2 2.3 0.7 1.4 0.3 2.3 0.7 1.9 0.2 2.3 1.1 173 11 197 165 3 0 3.3 2.8 04/09/2006 03:40:00 2.9 0.5 3.8 1.9 3 0.5 3.8 1.9 3 0.7 4.2 1.1 196 2 196 165 3.4 0.3 4.3 2.8 04/09/2006 03:50:00 2.7 0.3 3.4 2.3 2.9 0.4 3.8 2.3 3 0.4 4.2 2.3 191 8 197 165 4 0 4.3 3.5 04/09/2006 04:00:00 3.1 0.3 3.8 2.3 3.1 0.3 3.8 2.3 3.2 0.3 3.8 2.3 178 5 181 165 3.5 0.2 3.8 3 04/09/2006 04:10:00 4.1 0.4 4.6 3 4 0.4 4.6 3 3.9 0.5 4.6 2.6 188 2 192 165 3.1 0 3.5 2.6 04/09/2006 04:20:00 4.5 0.3 4.9 3.8 4.5 0.3 4.9 3.8 4.1 0.4 5.3 3 190 6 190 165 3.2 0 3.5 3 04/09/2006 04:30:00 4.9 0.2 5.3 4.6 5 0.2 5.7 4.6 5 0.3 5.7 4.2 198 2 199 165 3.5 0.1 3.8 3 04/09/2006 04:40:00 4.4 0.3 5.3 3.8 4.6 0.3 5.3 4.2 4.6 0.3 5.3 3.8 199 2 198 165 3.5 0 3.8 3.3 04/09/2006 04:50:00 4 0.3 4.6 3 4 0.3 4.6 3.4 4 0.4 4.6 3 193 6 199 165 3.3 0 3.5 3.3 04/09/2006 05:00:00 3.4 0.3 4.2 2.6 3.5 0.3 4.2 2.6 3.6 0.3 4.2 3 193 3 199 165 3.3 0 3.5 3.3 04/09/2006 05:10:00 3.7 0.3 4.2 3 3.8 0.3 4.6 3 4.1 0.4 4.9 3 192 3 196 165 3.6 0 3.8 3.5 04/09/2006 05:20:00 3.3 0.2 3.8 2.6 3.4 0.2 4.2 3 3.6 0.2 4.2 3 200 2 201 165 3.5 0 3.5 3.3 04/09/2006 05:30:00 3.7 0.3 4.6 3 3.8 0.3 4.6 3 4 0.4 4.9 2.6 195 4 191 165 3.6 0 3.8 3.5 04/09/2006 05:40:00 3.2 0.6 4.6 1.9 3.2 0.6 4.6 1.9 3.3 0.6 4.9 2.3 192 7 192 165 3.7 0 3.8 3.5 04/09/2006 05:50:00 2.8 0.8 4.6 1.5 2.8 0.8 4.6 1.5 2.8 0.7 4.6 1.5 201 17 200 165 3.6 0 3.8 3.5 04/09/2006 06:00:00 4.1 0.3 4.9 3 4.1 0.4 4.9 3 4.1 0.3 4.9 3.4 193 6 196 165 3.6 0.1 3.8 3.3 04/09/2006 06:10:00 4.5 0.4 5.3 3.4 4.7 0.4 5.3 3.8 4.9 0.5 5.7 3.4 197 4 200 165 3.6 0.1 3.8 3.3 04/09/2006 06:20:00 4.1 0.3 4.9 3.4 4.3 0.3 4.9 3.8 4.4 0.3 5.3 3.4 196 4 198 165 3.6 0 3.8 3.5 04/09/2006 06:30:00 4.3 0.7 6.1 3 4.4 0.7 6.1 3 4.3 0.7 6.1 2.6 207 9 215 165 3.6 0 3.8 3.5 04/09/2006 06:40:00 3.8 0.5 4.9 2.6 3.9 0.6 5.3 2.6 3.8 0.4 4.9 3 209 11 217 165 3.6 0.1 3.8 3.5 04/09/2006 06:50:00 3.8 0.5 5.3 3 3.9 0.5 5.3 3 4.1 0.4 5.3 3 199 6 204 165 3.4 0 3.5 3.3 04/09/2006 07:00:00 3.9 0.6 4.9 2.3 4 0.6 5.3 2.3 4.1 0.6 5.3 3 209 4 205 165 3.6 0 3.8 3.5 04/09/2006 07:10:00 3.2 0.5 4.6 2.3 3.2 0.5 4.6 2.3 3.1 0.4 4.2 2.3 230 9 244 165 3.8 0.1 4.3 3.5 04/09/2006 07:20:00 2.6 0.5 3.8 1.5 2.7 0.5 3.8 1.9 2.8 0.5 4.2 1.5 207 6 203 165 4 0 4.3 3.8 04/09/2006 07:30:00 2.8 0.6 3.8 1.1 2.9 0.6 3.8 1.1 3.3 0.5 4.2 2.3 202 5 194 165 4 0 4.3 3.8 04/09/2006 07:40:00 1.9 0.4 3 1.1 2 0.4 3 1.1 2.6 0.3 3.4 1.9 199 14 180 165 4 0 4.3 3.8 04/09/2006 07:50:00 2 0.6 3 0.7 1.9 0.5 3 0.7 2.2 0.6 3.4 1.1 184 7 178 165 4.1 0 4.3 3.8 04/09/2006 08:00:00 0.9 0.6 2.3 0.4 1 0.6 2.3 0.4 1.1 0.6 2.3 0.4 233 22 218 165 4.1 0 4.5 4 04/09/2006 08:10:00 0.7 0.3 1.5 0.4 0.7 0.3 1.5 0.4 1.4 0.5 2.3 0.4 311 19 322 165 4.3 0.1 4.5 4 04/09/2006 08:20:00 0.6 0.2 1.1 0.4 0.5 0.2 0.7 0.4 1.3 0.3 1.9 0.7 322 0 322 165 4.1 0 4.3 3.8 04/09/2006 08:30:00 0.6 0.4 1.5 0.4 0.6 0.4 1.9 0.4 1.1 0.3 1.9 0.4 303 9 305 165 4.4 0 4.8 4.3 04/09/2006 08:40:00 0.7 0.5 1.9 0.4 0.7 0.5 2.3 0.4 1.1 0.5 2.6 0.4 331 122 280 165 4 0.4 4.8 2.8 04/09/2006 08:50:00 1.2 0.7 2.6 0.4 1.3 0.7 3 0.4 1.4 0.7 3 0.4 276 11 279 165 3.7 0.3 4.3 2.8 04/09/2006 09:00:00 1.7 0.6 2.6 0.4 1.8 0.6 3 0.4 1.7 0.6 3 0.4 297 15 274 165 4.1 0.1 4.5 3.5 04/09/2006 09:10:00 1 0.5 2.3 0.4 0.9 0.5 2.3 0.4 1.4 0.3 2.3 0.7 330 27 304 165 4.2 0 4.5 3.5 04/09/2006 09:20:00 0.6 0.3 1.1 0.4 0.4 0 0.7 0.4 1 0.3 1.5 0.4 18 10 10 165 4.4 0.1 4.8 4 04/09/2006 09:30:00 0.4 0 0.7 0.4 0.4 0 0.7 0.4 0.6 0.3 1.5 0.4 84 33 106 165 4.5 0.1 4.8 4.3 04/09/2006 09:40:00 0.4 0.2 1.1 0.4 0.4 0.1 0.7 0.4 0.8 0.4 1.9 0.4 133 14 112 165 4.5 0.1 4.8 4.3 04/09/2006 09:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0.1 0.7 0.4 139 0 165 165 4.8 0.3 5.5 3.8 04/09/2006 10:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0.1 1.1 0.4 224 24 165 165 5.5 0 5.7 5 04/09/2006 10:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0.1 1.1 0.4 325 0 165 165 5.7 0.2 6 5 04/09/2006 10:20:00 0.8 0.6 2.3 0.4 0.7 0.5 2.6 0.4 1 0.7 2.6 0.4 188 102 133 165 5.5 0.1 5.7 5 04/09/2006 10:30:00 0.6 0.4 1.5 0.4 0.4 0.1 1.1 0.4 0.6 0.3 1.5 0.4 204 98 139 165 5.2 0.4 6 4.5 04/09/2006 10:40:00 0.7 0.4 1.9 0.4 0.5 0.2 1.5 0.4 0.7 0.4 1.9 0.4 346 6 348 165 6.6 0.2 7 5.7 04/09/2006 10:50:00 0.4 0 0.7 0.4 0.4 0 0.4 0.4 0.4 0.1 0.7 0.4 350 0 350 165 6.7 0.2 7 6.2 04/09/2006 11:00:00 0.6 0.3 1.9 0.4 0.4 0.2 1.5 0.4 0.6 0.3 1.9 0.4 39 53 103 165 6.1 0.2 6.7 5.7 04/09/2006 11:10:00 1 0.5 2.3 0.4 0.6 0.4 1.9 0.4 0.7 0.4 1.9 0.4 347 27 348 165 5.9 0 6.2 5.7 04/09/2006 11:20:00 1.7 0.5 3 0.4 1.2 0.5 2.3 0.4 1.5 0.5 2.6 0.4 343 20 320 165 6.2 0.1 6.5 6 04/09/2006 11:30:00 2.8 0.9 4.9 1.1 2.4 0.8 4.6 0.7 2.5 0.9 4.6 0.7 335 18 354 165 6.2 0 6.5 5.5 04/09/2006 11:40:00 3.1 1.1 6.5 0.4 2.6 1.1 6.1 0.4 3 1 6.1 0.7 349 13 353 165 6.3 0.1 6.7 6 04/09/2006 11:50:00 3 1.2 4.6 0.4 2.7 1.2 4.9 0.4 2.7 1.3 4.9 0.4 339 24 309 165 7.1 0 7.5 6.2 04/09/2006 12:00:00 3.5 0.6 5.7 1.9 3 0.6 4.9 1.5 3.3 0.7 4.9 1.1 6 16 358 165 6.1 0.5 7 5.5 04/09/2006 12:10:00 3.9 1 6.1 1.5 3 0.9 5.3 1.1 3.7 0.9 5.7 1.5 0 9 356 165 5.6 0.1 5.7 5.5 04/09/2006 12:20:00 3.4 0.9 4.9 1.1 2.9 0.9 5.3 0.7 3.2 0.9 4.9 0.7 352 19 351 165 5.5 0 5.7 5.5 04/09/2006 12:30:00 3 0.8 4.9 1.1 2.5 0.8 4.9 0.7 2.9 1 4.9 0.4 0 11 7 165 5.8 0.1 6 5.5 04/09/2006 12:40:00 2 0.8 4.2 0.4 1.9 0.8 4.2 0.4 1.8 0.7 3.4 0.4 356 36 291 165 6.1 0 6.2 5.7 04/09/2006 12:50:00 3.4 0.7 4.9 1.5 3.4 0.7 4.9 1.5 2.9 0.8 4.9 0.4 303 22 279 165 5.3 0.2 6 4.8 04/09/2006 13:00:00 3.9 0.7 5.7 2.3 3.6 0.8 5.3 1.5 3.8 0.7 5.7 2.3 342 13 353 165 5.4 0 5.7 5 04/09/2006 13:10:00 3.5 0.7 5.7 1.5 3.3 0.9 5.7 1.5 3.6 0.7 5.3 1.9 350 15 345 165 5.8 0.1 6 5.5 04/09/2006 13:20:00 2.5 0.4 3.4 1.5 2.6 0.4 3.8 1.1 2.5 0.5 3.8 1.1 314 17 355 165 5.9 0.1 6.2 5.5 04/09/2006 13:30:00 2.8 0.5 4.2 1.9 2.9 0.5 4.2 1.9 2.5 0.6 4.6 1.1 297 12 306 165 5.4 0.3 6 5 04/09/2006 13:40:00 2.3 0.6 3.8 0.4 2.5 0.5 3.8 1.1 2.3 0.7 3.8 0.4 291 11 278 165 5.2 0.1 5.7 5 04/09/2006 13:50:00 3.1 0.5 4.9 1.5 3.3 0.5 5.3 1.9 3 0.6 4.9 1.5 304 12 314 165 5.3 0.1 5.7 5 04/09/2006 14:00:00 3.8 0.7 6.1 2.3 3.8 0.7 6.1 2.6 3.5 0.7 5.7 1.9 319 17 332 165 5.5 0.3 6 4.8 04/09/2006 14:10:00 3.9 0.7 5.3 2.3 4 0.7 5.7 1.9 3.5 0.7 5.3 1.5 308 15 301 165 6.1 0.2 6.7 5.5 04/09/2006 14:20:00 6.1 1.7 10.3 2.6 6 1.7 10.7 3 5.7 2 9.9 1.9 329 21 344 165 5.5 0.2 6 5 04/09/2006 14:30:00 8 1 9.9 6.1 7.9 1.2 10.3 4.9 7.9 1 11.5 5.7 346 6 340 165 4.7 0.2 5 4.3 04/09/2006 14:40:00 6 0.9 8.4 3.8 5.5 1.3 8.4 3 5.9 0.9 8 3.4 350 11 340 165 5 0 5.2 4.8 04/09/2006 14:50:00 6.3 1.2 9.1 3.8 6 1.3 9.1 2.6 6.1 1.2 8.8 3.4 343 11 342 165 5.1 0.1 5.2 4.8 04/09/2006 15:00:00 6.8 1 8.8 4.6 5.8 1.2 9.1 2.6 7 1 9.9 4.9 352 9 4 165 5.4 0 5.7 5 04/09/2006 15:10:00 6.8 1.5 11.1 3.4 5.9 1.7 11.8 3 6.8 1.6 10.7 1.9 353 10 341 165 5.7 0.1 6 5 04/09/2006 15:20:00 7.4 1.1 10.7 4.2 6.8 1.5 9.9 3.4 7.1 1.2 11.1 4.2 351 8 12 165 5.2 0.1 5.7 5 04/09/2006 15:30:00 6.8 1.5 10.3 3 6.3 1.8 11.1 1.9 6.5 1.6 11.1 3 348 10 348 165 5 0 5.5 4.5 04/09/2006 15:40:00 5.6 0.8 7.6 3.8 4.9 1.1 7.6 2.3 5.3 0.8 7.6 3.4 350 10 2 165 5.4 0.1 5.7 5 04/09/2006 15:50:00 5 1.2 8 2.3 5 1.2 8 2.3 4.7 1 6.8 1.9 328 15 330 165 5.6 0.1 5.7 5 04/09/2006 16:00:00 6.1 1.7 10.3 2.6 6.1 1.6 10.3 3 5.8 1.7 10.3 2.6 321 15 318 165 5.9 0.2 6.2 5 04/09/2006 16:10:00 6 0.8 8.4 4.2 5.6 1 8.4 2.6 5.4 0.8 8 3.4 338 17 11 165 5.6 0.1 5.7 5 04/09/2006 16:20:00 7 1.3 10.7 3.4 6.9 1.3 10.3 3.4 6.6 1.3 9.5 3.4 327 9 326 165 5.6 0.1 5.7 5 04/09/2006 16:30:00 9 1.6 13 4.9 8.9 1.6 13 5.3 8 1.5 12.2 4.9 314 8 315 165 5.4 0.1 5.7 5 04/09/2006 16:40:00 10.6 1 13 8 10.5 1 12.6 7.6 9.7 1.2 12.6 6.5 315 6 304 165 5.1 0 5.5 4.8 04/09/2006 16:50:00 11.5 0.9 13.3 7.6 11.3 0.9 13.7 8 10.6 1.1 13 7.2 314 5 316 165 5.2 0.1 5.5 4.8 04/09/2006 17:00:00 11.4 1.2 14.5 8 11.2 1.1 14.1 8.4 11 1.2 14.1 7.6 320 6 305 165 5.2 0.1 5.7 4.8 04/09/2006 17:10:00 11.1 1 13.3 8 11 1 13.3 7.6 10.5 1.1 13 6.5 316 7 316 165 4.9 0.4 5.7 4.5 04/09/2006 17:20:00 12 1.3 14.9 8 11.8 1.3 14.9 8.4 11.3 1.3 13.7 7.6 318 7 310 165 4.4 0.1 4.8 4 04/09/2006 17:30:00 12.8 1.5 15.6 7.2 12.5 1.5 15.6 7.2 12 1.5 14.5 6.8 318 7 307 165 4.3 0.1 4.8 3.8 04/09/2006 17:40:00 13.5 0.9 16.1 10.3 13.3 0.8 15.6 9.9 12.9 1.1 15.3 9.1 317 4 316 165 4.3 0 4.8 3.8 04/09/2006 17:50:00 14 0.8 15.6 11.1 13.7 0.8 15.3 11.5 13.5 1.1 16.1 9.9 318 4 319 165 4.5 0.2 4.8 4.3 04/09/2006 18:00:00 15.3 1.1 18.3 10.3 15.1 1.1 17.9 10.3 14.7 1.2 18.3 11.1 317 6 321 165 4.3 0.1 4.8 4 04/09/2006 18:10:00 15.1 1.2 18.3 11.5 14.9 1.2 17.9 11.1 14.3 1.4 17.2 9.1 316 6 315 165 4.3 0 4.5 4.3 04/09/2006 18:20:00 15.4 1.2 17.9 11.5 15.2 1.1 17.6 11.8 14.9 1.4 18.7 11.1 318 5 317 165 4.1 0 4.5 3.8 04/09/2006 18:30:00 15 1.7 19.5 10.3 14.8 1.7 19.1 10.3 14.2 1.7 17.6 9.5 317 6 313 165 4 0.2 4.8 3.5 04/09/2006 18:40:00 15 1.2 17.9 12.2 14.9 1.2 18.3 11.8 14.4 1.4 17.9 9.9 315 5 311 165 3.8 0.1 4 3.3 04/09/2006 18:50:00 14.3 1.1 17.2 11.1 14.2 1.2 16.8 11.1 13.5 1.5 17.2 9.5 315 6 315 165 3.6 0.1 3.8 3.3 04/09/2006 19:00:00 13.2 1 16.4 10.7 13 1.1 16.8 10.3 12.5 1.2 15.3 9.5 315 6 310 165 3.5 0 3.8 3.3 04/09/2006 19:10:00 13.9 1.1 16.4 10.3 13.7 1.1 16.1 10.3 13.1 1.3 16.1 9.5 316 5 307 165 3.3 0 3.5 3 04/09/2006 19:20:00 14 1.1 16.4 10.7 13.9 1.1 16.4 10.7 13.1 1.6 17.6 8.8 315 7 312 165 3 0 3.3 2.8 04/09/2006 19:30:00 13.7 1.2 17.2 10.7 13.5 1.2 17.2 10.7 12.3 1.5 15.6 8 313 6 312 165 2.9 0 3 2.8 04/09/2006 19:40:00 13.7 1.1 16.1 10.3 13.6 1.2 16.1 10.3 12.4 1.5 15.3 8.8 312 6 310 165 2.8 0 3 2.6 04/09/2006 19:50:00 14.9 1.2 18.7 11.8 14.7 1.2 18.3 11.5 14.5 1.2 17.9 11.1 317 5 313 165 2.7 0 2.8 2.6 04/09/2006 20:00:00 14.7 1 17.2 12.2 14.6 1 17.2 11.8 14.1 1.1 16.4 10.7 317 6 315 165 2.6 0 2.8 2.3 04/09/2006 20:10:00 15.8 1.2 18.7 13 15.6 1.2 18.7 13 14.5 1.4 17.9 10.3 314 6 308 165 2.4 0 2.6 2.3 04/09/2006 20:20:00 16.5 1.3 19.5 13.3 16.4 1.3 19.9 13.3 15.9 1.6 19.5 11.5 315 6 311 165 2.3 0 2.6 2.3 04/09/2006 20:30:00 17.2 1.2 19.5 13.7 17 1.2 19.5 13.7 16.4 1.4 19.5 11.8 314 5 314 165 2.3 0 2.6 2.3 04/09/2006 20:40:00 18 1 20.2 14.9 18 1 20.2 14.5 16.1 1.5 19.1 11.1 311 4 308 165 2.3 0 2.6 2.3 04/09/2006 20:50:00 17.6 1 20.2 14.9 17.5 1 20.2 14.9 16.5 1.2 19.5 12.6 313 4 309 165 2.3 0 2.3 2.1 04/09/2006 21:00:00 17.9 1.2 20.6 14.9 17.8 1.3 20.6 14.5 16.5 1.5 20.6 10.7 312 5 311 165 2.2 0 2.3 1.8 04/09/2006 21:10:00 18.2 1 20.2 14.5 18.1 1 19.9 14.5 17.5 1.2 20.2 13.7 313 4 310 165 2 0 2.3 1.8 04/09/2006 21:20:00 18.2 1.1 20.6 15.3 18.1 1.2 20.6 14.9 16.5 1.4 19.5 12.2 311 4 308 165 2 0 2.1 1.8 04/09/2006 21:30:00 17.3 1.2 21 14.1 17.2 1.2 21 13.7 15.5 1.5 20.2 11.8 311 4 309 165 1.9 0 2.1 1.8 04/09/2006 21:40:00 17.2 1.3 20.2 13 17.1 1.3 20.2 13 15.9 1.8 20.6 11.1 312 5 310 165 1.9 0 2.1 1.8 04/09/2006 21:50:00 17.7 1.5 21.8 13.7 17.6 1.6 21 13.3 16.6 1.7 20.6 11.8 312 5 314 165 2 0 2.3 1.8 04/09/2006 22:00:00 17.4 1.3 20.2 13.7 17.4 1.3 20.2 14.1 15.2 1.8 19.5 10.7 310 5 304 165 1.9 0 2.1 1.8 04/09/2006 22:10:00 17.7 1.4 20.6 13.3 17.6 1.5 20.6 13.7 15 1.7 19.1 10.3 309 4 307 165 1.9 0 1.8 1.8 04/09/2006 22:20:00 17 1.4 20.6 12.2 16.9 1.4 20.2 11.8 14.5 1.7 18.7 9.9 308 5 307 165 1.8 0 1.8 1.6 04/09/2006 22:30:00 15.6 1.3 19.1 11.8 15.5 1.3 19.1 11.8 13.1 1.7 16.4 9.1 308 5 309 165 1.7 0 1.8 1.6 04/09/2006 22:40:00 15.3 1.4 18.3 10.7 15.2 1.4 18.3 10.7 12.4 1.7 17.2 8.4 307 5 307 165 1.7 0 1.8 1.6 04/09/2006 22:50:00 15.1 1.1 18.3 11.8 15.1 1.1 18.3 11.8 12 1.5 16.4 8.8 306 5 305 165 1.6 0 1.8 1.4 04/09/2006 23:00:00 14.3 1.4 17.6 11.1 14.2 1.5 17.6 10.7 11.5 1.8 17.6 7.6 306 6 313 165 1.6 0 1.8 1.4 04/09/2006 23:10:00 15.1 1.3 18.3 12.2 15.1 1.4 18.3 12.2 11.8 1.7 16.1 8.4 304 6 301 165 1.6 0 1.8 1.6 04/09/2006 23:20:00 15.9 1.3 18.7 11.8 15.9 1.4 18.7 11.5 11.4 1.2 16.1 8.4 303 5 306 165 1.5 0 1.6 1.4 04/09/2006 23:30:00 15.2 1.6 19.1 11.5 15.1 1.6 18.7 11.5 11.2 1.3 14.9 8 302 5 298 165 1.5 0 1.6 1.4 04/09/2006 23:40:00 15.5 1.2 17.9 11.5 15.5 1.2 17.9 11.1 11.4 1.3 15.3 8.4 303 5 300 165 1.4 0 1.6 1.4 04/09/2006 23:50:00 15.3 1.4 18.7 11.1 15.3 1.4 18.3 11.1 11.4 1.3 15.6 8 303 5 301 165 1.3 0 1.4 1.1 04/10/2006 00:00:00 15.8 1.4 18.3 11.8 15.9 1.4 18.3 11.1 11.5 1.2 15.6 8.4 302 5 307 165 1.2 0 1.4 0.9 04/10/2006 00:10:00 15 1.6 17.9 10.7 15 1.6 17.9 10.3 10.9 1.3 14.9 7.2 301 5 301 165 1.1 0 1.4 0.9 04/10/2006 00:20:00 14.3 1.3 16.8 11.1 14.3 1.3 17.2 11.1 10.4 1.1 13.7 7.6 302 5 308 165 1.1 0 1.4 0.9 04/10/2006 00:30:00 14 1.2 16.8 10.3 14 1.3 16.8 9.9 11.2 1.4 14.9 8.4 306 6 301 165 1.1 0 1.4 0.9 04/10/2006 00:40:00 13.5 1.4 16.4 8.4 13.5 1.5 16.8 8.4 10.8 1.3 15.6 7.6 307 5 303 165 1.1 0 1.4 0.9 04/10/2006 00:50:00 13.5 1.2 16.1 7.2 13.5 1.3 16.1 7.6 10.6 1.4 14.5 7.2 306 5 305 165 1.1 0 1.4 0.9 04/10/2006 01:00:00 14.2 1.7 19.1 9.1 14.2 1.7 18.7 8.8 10.6 1.6 15.3 6.8 304 5 298 165 1.2 0 1.4 1.1 04/10/2006 01:10:00 14.3 1.1 17.2 10.7 14.3 1.1 16.8 10.7 10.1 1.2 14.5 7.6 304 4 304 165 1.1 0 1.4 0.9 04/10/2006 01:20:00 13.8 1.2 16.1 10.3 13.9 1.3 16.1 10.3 9.8 1.1 13.3 7.2 304 4 307 165 0.9 0 1.1 0.9 04/10/2006 01:30:00 13.9 0.8 15.6 9.9 13.9 0.9 16.4 9.9 9.8 1 13 7.2 303 4 299 165 0.8 0 0.9 0.7 04/10/2006 01:40:00 12.8 1.1 15.3 9.5 12.8 1.1 15.6 9.5 9.3 1.2 13.3 6.5 302 5 302 165 0.8 0 0.9 0.7 04/10/2006 01:50:00 12.7 1.1 15.6 9.5 12.7 1.1 15.3 9.5 9.6 1.1 13 6.5 304 5 296 165 0.8 0 0.9 0.9 04/10/2006 02:00:00 13.1 1.1 15.6 10.3 13.1 1.1 15.3 10.3 9.6 1.1 12.6 7.2 304 5 300 165 0.8 0 0.9 0.7 04/10/2006 02:10:00 12.5 1 15.6 9.9 12.5 1 16.1 9.9 9.3 1.1 13 6.8 304 5 298 165 0.8 0 0.9 0.7 04/10/2006 02:20:00 13.2 0.9 16.1 10.3 13.2 1 15.6 10.7 9.7 1.2 13.3 7.2 302 5 300 165 0.7 0 0.9 0.7 04/10/2006 02:30:00 13.6 1 15.6 11.1 13.6 1 16.1 11.5 9.7 1 13 7.2 302 5 307 165 0.8 0 0.9 0.7 04/10/2006 02:40:00 14.2 1 16.4 11.1 14.3 1.1 16.8 11.1 10.2 1.1 14.1 7.6 301 5 304 165 0.8 0 0.9 0.7 04/10/2006 02:50:00 14.2 1.1 16.4 11.5 14.2 1.1 16.4 11.1 10.1 1.1 13.7 8 301 5 300 165 0.8 0 0.9 0.7 04/10/2006 03:00:00 14 0.9 16.1 11.8 14 0.9 16.1 11.5 9.5 1 13.7 6.8 302 3 304 165 0.8 0 0.9 0.7 04/10/2006 03:10:00 12.9 1 14.9 9.5 13 1 14.9 9.9 9.1 0.9 12.2 7.2 301 4 302 165 0.8 0 0.9 0.7 04/10/2006 03:20:00 13.1 0.8 14.9 10.7 13.1 0.9 14.9 10.7 9.2 1 12.6 7.2 299 4 298 165 1 0 1.1 0.9 04/10/2006 03:30:00 13.1 0.7 14.5 10.3 13.1 0.8 14.5 10.7 8.9 0.8 11.5 6.8 301 3 300 165 1 0 1.4 0.9 04/10/2006 03:40:00 13.5 1 15.6 9.9 13.6 1 16.1 10.3 9.5 1 13 6.5 302 4 307 165 1.1 0 1.4 0.9 04/10/2006 03:50:00 13.2 1.1 15.3 9.9 13.2 1.1 15.3 9.9 9.5 1 13 7.2 301 5 300 165 1.1 0 1.4 0.9 04/10/2006 04:00:00 12.8 1.2 16.4 10.3 12.8 1.2 16.4 9.9 9 1 12.6 6.8 302 5 308 165 1.1 0 1.4 0.9 04/10/2006 04:10:00 13.2 1 15.3 11.1 13.2 1 15.6 11.1 9.4 1 12.6 7.2 301 4 304 165 1.1 0 1.4 0.9 04/10/2006 04:20:00 12.4 0.9 14.9 9.9 12.4 0.9 14.9 9.9 9.1 1 12.2 6.5 300 5 302 165 1.1 0 1.4 0.9 04/10/2006 04:30:00 12.6 0.9 15.6 10.3 12.7 1 15.6 10.7 9.1 1.2 13 6.8 299 5 303 165 1.1 0 1.4 0.9 04/10/2006 04:40:00 12.9 1.1 15.3 9.5 12.9 1.1 15.3 9.9 9.2 1.2 13.7 6.8 299 4 302 165 1.1 0 1.4 0.9 04/10/2006 04:50:00 12.7 1.1 15.6 9.9 12.8 1.1 15.6 10.3 9.1 1.1 13 6.8 302 4 296 165 1.1 0 1.4 0.9 04/10/2006 05:00:00 12.5 1 14.9 9.1 12.5 1 14.9 9.1 9.1 1 12.2 6.5 304 4 301 165 1 0 1.4 0.9 04/10/2006 05:10:00 12.9 1.1 15.3 9.9 12.9 1.1 15.3 9.9 8.8 0.9 11.1 6.1 302 4 307 165 1.1 0 1.4 0.9 04/10/2006 05:20:00 12.9 0.9 14.5 9.9 12.9 0.9 14.5 9.9 9 1 13 6.8 300 4 300 165 1.1 0 1.4 0.9 04/10/2006 05:30:00 12.7 0.7 14.5 9.1 12.8 0.7 14.5 9.5 8.8 0.9 13 7.2 301 3 293 165 1.1 0 1.4 0.9 04/10/2006 05:40:00 11.5 1.1 13.7 8 11.5 1.1 14.1 8 9.1 1.2 12.6 6.1 306 5 302 165 1.1 0 1.4 0.9 04/10/2006 05:50:00 12.2 0.9 14.1 9.9 12.2 1 14.1 9.9 10.1 1.1 12.6 7.6 308 4 307 165 1.1 0 1.4 0.9 04/10/2006 06:00:00 11.7 1 13.7 8.8 11.6 1 13.3 8.4 10.3 1.3 13.7 6.8 310 5 310 165 1.1 0 1.4 0.9 04/10/2006 06:10:00 12.8 1 15.3 9.1 12.8 1 15.3 9.9 10.2 1.1 13 7.2 307 5 304 165 1.2 0 1.4 1.1 04/10/2006 06:20:00 13 1 15.6 9.9 13 1 15.6 9.9 10.4 1.5 14.5 7.2 307 5 312 165 1.3 0 1.4 1.1 04/10/2006 06:30:00 12.4 1.1 15.3 9.1 12.4 1.1 14.9 9.1 9.2 1 12.6 7.2 304 5 305 165 1.4 0 1.4 1.4 04/10/2006 06:40:00 13.9 1.2 16.4 9.9 13.9 1.2 16.4 10.7 10.3 1.3 13.7 7.6 302 5 304 165 1.4 0 1.6 1.4 04/10/2006 06:50:00 13.2 0.9 14.9 9.9 13.2 0.9 15.3 9.9 9.9 1.3 13.3 6.8 305 5 302 165 1.4 0 1.6 1.4 04/10/2006 07:00:00 12.9 1 15.6 10.3 12.8 1 15.6 10.3 9.5 1.1 12.6 7.2 304 4 305 165 1.4 0 1.6 1.4 04/10/2006 07:10:00 14.6 0.9 16.4 12.2 14.6 0.9 16.4 11.8 10.3 1.1 14.5 8 302 4 310 165 1.4 0 1.6 1.4 04/10/2006 07:20:00 14 1 16.8 11.5 14 1 16.8 11.5 10.1 1.2 14.5 7.6 302 4 294 165 1.4 0 1.6 1.4 04/10/2006 07:30:00 13.5 1.3 16.8 10.7 13.5 1.4 17.2 10.7 10.3 1.4 16.4 6.8 301 6 297 165 1.5 0 1.6 1.4 04/10/2006 07:40:00 15.3 1.1 18.3 12.2 15.3 1.1 18.3 11.8 11.1 1.3 16.1 8 301 6 310 165 1.6 0 1.8 1.4 04/10/2006 07:50:00 15.4 1.3 17.9 11.5 15.4 1.3 18.3 11.5 11.1 1.2 15.3 8 300 5 300 165 1.7 0 1.8 1.6 04/10/2006 08:00:00 14.7 1.3 17.2 11.1 14.7 1.3 17.2 11.1 10.8 1.3 14.9 7.6 299 5 299 165 1.7 0 1.8 1.6 04/10/2006 08:10:00 14.3 1.2 17.2 11.1 14.3 1.2 17.2 11.1 10.6 1.2 14.1 7.2 300 5 310 165 1.7 0 1.8 1.6 04/10/2006 08:20:00 12.5 1 14.9 10.3 12.4 1 14.9 10.3 10.2 1.7 14.5 6.8 303 8 303 165 1.5 0 1.8 1.4 04/10/2006 08:30:00 13.3 1.2 15.6 9.9 13.1 1.2 15.6 10.3 12 1.3 15.3 7.2 310 5 310 165 1.7 0.1 1.8 1.4 04/10/2006 08:40:00 11.9 1.3 15.3 8.8 11.8 1.3 14.9 8.8 11 1.5 14.1 7.6 312 5 308 165 2 0 2.3 1.6 04/10/2006 08:50:00 10.9 1 13 8 10.8 0.9 13 8 9.4 1.2 12.6 6.5 309 6 310 165 2.1 0 2.3 1.8 04/10/2006 09:00:00 11.5 1.1 14.5 8.8 11.4 1.1 14.1 8.8 10.3 1.5 14.1 6.5 310 6 304 165 1.9 0 2.1 1.8 04/10/2006 09:10:00 11.2 1.2 14.5 7.6 11.1 1.2 14.1 8 9.6 1.3 13 6.8 307 8 300 165 1.9 0 1.8 1.8 04/10/2006 09:20:00 11.8 1.5 15.6 8 11.8 1.5 16.1 7.6 9.7 1.4 13.7 6.1 304 7 292 165 1.9 0 2.1 1.8 04/10/2006 09:30:00 13.1 1.1 15.6 9.5 13.1 1.1 15.6 9.9 9.6 1 13 6.8 302 5 303 165 1.8 0 1.8 1.8 04/10/2006 09:40:00 12 1.4 15.3 7.6 12.1 1.4 15.3 7.6 8.9 1.1 12.2 6.1 300 5 295 165 2 0 2.3 1.8 04/10/2006 09:50:00 10.1 1.1 12.6 7.2 10.2 1 13 7.2 7.7 1.1 11.5 5.3 300 5 297 165 2.1 0 2.3 1.8 04/10/2006 10:00:00 9.3 0.8 11.8 6.8 9.3 0.8 11.5 7.2 7.1 0.9 9.9 4.6 301 5 304 165 2.4 0.1 2.6 1.8 04/10/2006 10:10:00 9.6 0.8 11.8 7.2 9.7 0.8 11.8 7.2 7.6 1 11.5 4.9 300 6 298 165 2.6 0 2.8 2.3 04/10/2006 10:20:00 11 0.9 13.3 8.8 11 0.9 13.3 8.4 9.3 1.5 13 5.7 294 7 289 165 2.4 0.2 2.8 1.8 04/10/2006 10:30:00 10.4 1 13 8 10.5 1 13.3 8 9.2 1.5 12.6 5.3 292 6 289 165 2.3 0.2 2.6 1.8 04/10/2006 10:40:00 9.4 0.9 11.8 7.2 9.5 1 11.8 7.2 8.4 1.7 11.8 4.6 291 8 295 165 2.4 0.1 2.8 2.1 04/10/2006 10:50:00 9.7 0.9 11.5 7.2 9.8 0.9 11.8 7.2 8.4 1.5 11.8 5.3 293 8 296 165 2.6 0.1 2.8 2.3 04/10/2006 11:00:00 9.8 1 12.2 7.2 9.9 1.1 12.2 7.2 8.2 1.2 11.5 4.9 296 9 291 165 2.5 0.1 2.8 2.3 04/10/2006 11:10:00 9.8 1 12.2 6.8 9.9 1 12.2 7.2 8.5 1.2 11.5 5.7 301 10 295 165 2.4 0 2.6 2.3 04/10/2006 11:20:00 9 0.9 12.2 5.7 9.1 1 11.8 6.1 7.1 1 10.3 4.6 301 7 292 165 2.7 0 2.8 2.1 04/10/2006 11:30:00 7.8 1.2 11.1 4.2 7.8 1.2 11.1 4.2 6.7 1.3 10.3 3.4 307 9 305 165 2.9 0.2 3.3 2.3 04/10/2006 11:40:00 9.7 1.1 12.6 6.8 9.7 1.1 12.6 6.8 8.4 1 10.7 5.7 309 7 294 165 2.9 0.1 3.5 2.6 04/10/2006 11:50:00 10.6 0.9 13.3 8 10.6 0.9 13.3 8 8.6 1.1 11.8 6.1 306 7 285 165 2.7 0.3 3 2.1 04/10/2006 12:00:00 9.7 1.2 12.6 6.1 9.6 1.2 12.6 6.1 8.8 1.3 12.2 5.7 308 11 308 165 2.9 0.2 3 2.1 04/10/2006 12:10:00 8.7 0.8 10.7 6.5 8.7 0.8 11.1 6.5 7.4 1.1 9.9 4.9 305 9 295 165 3.1 0.1 3.5 2.3 04/10/2006 12:20:00 10.1 1.4 13 6.8 10.1 1.4 13 6.8 8.3 1.5 13 4.2 304 8 315 165 3 0.2 3.5 2.6 04/10/2006 12:30:00 9.8 1.5 13 6.1 9.8 1.5 13 6.5 8.8 1.6 13 5.3 311 7 305 165 2.7 0.2 3 2.1 04/10/2006 12:40:00 7.6 2.2 13.7 3 7.6 2.2 14.1 3.8 6.9 2 13.3 3 302 15 291 165 3.3 0.2 3.8 2.3 04/10/2006 12:50:00 10.7 1.5 14.1 6.5 10.7 1.5 14.1 6.1 9.3 1.9 14.1 4.2 294 10 285 165 2.7 0.3 3.3 2.1 04/10/2006 13:00:00 11.5 1.3 14.5 7.6 11.5 1.3 14.5 8 9.3 1.5 13.7 5.3 295 8 304 165 2.2 0 2.6 1.8 04/10/2006 13:10:00 11.4 1.1 14.1 8.4 11.4 1 13.7 8.4 9.4 1.5 13.3 6.5 300 9 301 165 2.1 0.2 2.8 1.6 04/10/2006 13:20:00 12.6 1.3 16.1 9.1 12.5 1.4 16.1 9.1 10.4 1.7 15.3 7.2 305 8 304 165 2.3 0.2 2.8 1.6 04/10/2006 13:30:00 10.8 1.5 15.6 8 10.8 1.5 15.3 8 8.7 1.6 12.6 6.1 298 10 302 165 2.3 0.1 2.6 1.8 04/10/2006 13:40:00 8.5 0.9 10.7 5.3 8.5 0.9 10.3 5.7 7.2 1 9.9 4.6 306 7 313 165 2.6 0 2.8 2.3 04/10/2006 13:50:00 8.1 1.3 10.7 4.9 8.5 1.1 10.7 5.3 7.6 1.1 10.3 4.6 293 19 296 165 2.7 0 3 2.6 04/10/2006 14:00:00 10.7 1.8 14.5 6.5 10.7 1.8 14.5 6.5 9 1.7 13.3 5.3 309 7 298 165 2.7 0.3 3.3 2.1 04/10/2006 14:10:00 11 1.7 14.9 7.2 11 1.7 14.9 7.2 9.1 2.1 14.5 5.7 302 9 304 165 2.4 0.1 2.8 2.1 04/10/2006 14:20:00 13.2 1.3 17.6 9.9 13.1 1.3 17.6 9.9 10.9 1.8 15.3 7.2 307 9 300 165 2.2 0.2 2.6 1.6 04/10/2006 14:30:00 12.1 1.4 15.3 8.4 12.1 1.4 15.3 8.4 10.4 1.5 15.3 7.2 307 9 314 165 2.3 0.1 2.6 1.8 04/10/2006 14:40:00 10.6 1.6 14.1 6.5 10.6 1.7 14.1 6.5 8.9 1.4 12.6 5.7 311 10 307 165 2.4 0.1 2.8 1.8 04/10/2006 14:50:00 10.8 2.1 14.5 6.1 10.7 2.1 14.5 6.1 9.2 2.1 13.7 4.6 310 9 303 165 2.3 0.2 2.8 1.6 04/10/2006 15:00:00 9.1 1.1 11.8 5.7 9.1 1.1 11.8 5.7 8.5 1.2 11.5 5.7 314 9 309 165 2.3 0.1 2.6 1.6 04/10/2006 15:10:00 10.2 1.3 14.5 6.5 10.1 1.3 14.1 6.5 8.6 1.5 13 5.3 309 8 310 165 2.6 0 2.8 2.3 04/10/2006 15:20:00 10.4 1.9 16.4 5.7 10.3 1.8 16.1 6.1 9.6 1.8 16.4 5.3 317 12 319 165 2.9 0.1 3.3 2.3 04/10/2006 15:30:00 11.2 1.9 15.3 5.7 11.1 1.8 14.9 4.9 10.2 2.1 16.1 5.3 316 11 314 165 2.6 0.2 3 2.1 04/10/2006 15:40:00 12.1 1.9 17.6 7.6 12 1.9 17.6 7.6 10.6 2 16.8 6.5 311 8 298 165 2.6 0.1 2.8 2.3 04/10/2006 15:50:00 14.8 1.5 18.3 10.3 14.7 1.5 18.3 9.9 13 2.1 18.3 6.5 310 7 305 165 2.1 0.1 2.6 1.8 04/10/2006 16:00:00 13.2 1.5 17.2 9.5 13.1 1.5 16.8 9.5 10.7 1.7 15.3 6.8 306 6 304 165 1.5 0.3 2.1 0.9 04/10/2006 16:10:00 11.9 1.7 16.1 7.2 11.8 1.7 16.1 7.2 10.2 1.7 16.1 6.1 304 9 302 165 1.6 0.2 1.8 0.9 04/10/2006 16:20:00 12.4 1.5 15.6 9.1 12.3 1.5 15.6 9.5 10.2 1.6 14.9 6.5 301 9 293 165 1.8 0.2 2.1 1.4 04/10/2006 16:30:00 12.8 1.5 16.4 9.5 12.7 1.6 16.8 9.5 10.5 1.9 16.4 6.1 302 9 305 165 1.8 0.1 2.1 1.4 04/10/2006 16:40:00 12.7 1.5 16.1 8.8 12.7 1.5 15.6 8.4 10.2 1.5 14.5 6.5 299 9 293 165 2 0 2.3 1.6 04/10/2006 16:50:00 12.1 1.4 15.6 8.4 12.1 1.4 15.3 8.4 9.5 1.5 13.7 6.1 297 8 298 165 1.7 0.1 2.1 1.1 04/10/2006 17:00:00 13.4 1.7 17.9 9.9 13.5 1.7 17.9 9.5 11.4 1.7 16.1 7.2 292 7 293 165 1.7 0 2.3 1.4 04/10/2006 17:10:00 13.6 1.7 17.9 9.5 13.5 1.7 18.3 9.5 10.8 1.7 15.3 7.2 300 8 292 165 1.7 0.1 1.8 1.4 04/10/2006 17:20:00 13.5 1.5 17.2 9.5 13.5 1.5 16.8 9.5 10.9 1.5 15.6 7.6 300 8 298 165 1.5 0.1 1.8 1.1 04/10/2006 17:30:00 15.7 1.5 18.7 11.1 15.7 1.5 18.7 10.7 12.1 1.3 16.4 8.4 301 7 302 165 1.3 0.1 1.6 0.9 04/10/2006 17:40:00 16.6 1.4 20.2 13.3 16.6 1.4 20.6 13 13 1.6 17.2 9.5 300 6 302 165 1 0.2 1.4 0.9 04/10/2006 17:50:00 18.1 1.4 21.4 14.1 18.1 1.5 21.4 14.1 13.5 1.5 17.6 9.9 299 5 297 165 0.8 0 0.9 0.7 04/10/2006 18:00:00 16.8 1.3 20.6 13.3 16.9 1.3 21 13.3 13.4 1.7 18.3 9.5 294 6 290 165 0.9 0 1.4 0.9 04/10/2006 18:10:00 15.7 0.9 18.3 13 15.8 1 18.3 12.2 13.2 1.8 17.2 9.1 291 5 289 165 1.1 0 1.4 0.9 04/10/2006 18:20:00 14.4 1.5 18.3 10.7 14.4 1.5 17.9 10.7 11.7 1.7 16.8 8 296 7 300 165 1.1 0 1.4 0.9 04/10/2006 18:30:00 14 1.5 18.7 10.7 14 1.6 18.3 10.7 11.6 2.5 18.3 7.6 295 8 285 165 1.1 0 1.4 0.9 04/10/2006 18:40:00 15.2 1 17.9 12.2 15.3 1.1 18.3 12.2 12.9 2.1 16.8 8.4 292 5 293 165 0.9 0 1.1 0.9 04/10/2006 18:50:00 14.9 1.5 18.7 11.1 14.9 1.6 18.7 10.7 11.7 2.2 17.6 8 296 6 288 165 0.9 0 0.9 0.9 04/10/2006 19:00:00 14.4 1.1 16.8 11.1 14.4 1.1 16.8 11.1 11.4 1.5 15.6 8 296 6 296 165 0.8 0 0.9 0.9 04/10/2006 19:10:00 14 1.5 16.8 10.3 14 1.6 16.8 10.3 11.1 2 16.1 6.8 297 7 300 165 0.8 0 0.9 0.7 04/10/2006 19:20:00 12.9 1.1 14.9 9.1 13 1.1 15.3 9.1 10.4 1.6 14.5 6.8 293 5 298 165 0.7 0 0.9 0.7 04/10/2006 19:30:00 12.2 0.7 13.7 9.1 12.3 0.7 14.1 9.5 11.6 1.2 14.5 8 284 5 281 165 0.4 0 0.7 0.2 04/10/2006 19:40:00 12.6 1.3 17.2 9.5 12.6 1.3 17.2 9.5 11.1 1.9 16.1 6.1 288 7 292 165 0.2 0 0.4 -0.1 04/10/2006 19:50:00 12.7 1 15.3 9.5 12.7 1 15.6 9.9 11.1 1.6 16.1 7.6 288 5 292 165 0.1 0 0.2 -0.1 04/10/2006 20:00:00 11.4 1 13.7 8.4 11.6 0.9 14.1 8.8 10.6 1.2 13.3 6.1 285 6 286 165 0 0 0.2 -0.1 04/10/2006 20:10:00 9.5 1.1 12.6 6.5 9.7 1.1 12.6 6.8 9.1 1.3 12.2 4.9 284 5 286 165 -0.1 0 -0.1 -0.3 04/10/2006 20:20:00 6.8 0.8 8.8 4.6 7.1 0.8 9.1 4.9 6.5 0.8 9.1 3.8 281 7 275 165 -0.3 0 -0.1 -0.5 04/10/2006 20:30:00 6.6 1 9.1 4.6 6.7 1 9.1 4.2 5.8 1.3 9.1 3 287 9 279 165 -0.3 0 -0.3 -0.5 04/10/2006 20:40:00 7.2 1.1 9.9 4.2 7.2 1.1 9.9 4.2 5.8 1.1 9.9 3.4 296 9 295 165 -0.4 0 -0.3 -0.5 04/10/2006 20:50:00 9 1.1 11.8 6.1 9 1.1 11.8 6.1 7.5 1.2 10.3 4.6 291 6 294 165 -0.3 0 -0.1 -0.5 04/10/2006 21:00:00 9.1 0.7 10.7 7.2 9.1 0.8 10.7 7.2 7.9 1.2 11.1 4.9 289 5 287 165 -0.3 0 -0.1 -0.5 04/10/2006 21:10:00 9.9 0.7 11.8 7.6 10 0.8 11.8 7.6 8.7 1.1 11.5 5.7 288 4 291 165 -0.4 0 -0.3 -0.5 04/10/2006 21:20:00 10.3 0.9 12.6 8 10.4 1 12.6 7.6 9.1 1.3 12.2 5.3 288 5 290 165 -0.5 0 -0.3 -0.5 04/10/2006 21:30:00 9.6 0.8 11.1 7.2 9.7 0.8 11.5 7.6 8.3 1.2 11.1 5.3 290 6 291 165 -0.5 0 -0.3 -0.8 04/10/2006 21:40:00 9.6 0.7 11.1 7.2 9.6 0.7 11.1 7.2 7.4 1 9.9 4.9 294 5 287 165 -0.5 0 -0.3 -0.5 04/10/2006 21:50:00 9.3 0.6 11.1 7.2 9.3 0.7 11.1 7.2 6.8 1 9.9 4.9 297 4 302 165 -0.6 0.1 -0.3 -0.8 04/10/2006 22:00:00 10.4 0.6 11.8 8.8 10.5 0.6 11.8 8.8 7.9 1 10.7 5.7 295 3 296 165 -0.6 0 -0.3 -1 04/10/2006 22:10:00 11.3 0.5 12.6 9.5 11.4 0.5 13 9.1 8.8 1 12.2 6.5 294 3 294 165 -0.3 0 -0.3 -0.5 04/10/2006 22:20:00 11.1 0.8 13.3 8.8 11.1 0.8 13.7 8.4 8.1 1.1 11.8 5.7 297 4 295 165 -0.3 0 -0.1 -0.5 04/10/2006 22:30:00 11.2 1 13.3 9.1 11.3 1 13.3 9.1 9.1 1.6 13 6.5 292 6 285 165 -0.3 0 -0.1 -0.5 04/10/2006 22:40:00 10.6 0.9 13 8.4 10.6 0.9 12.6 8.4 8.1 1.2 12.6 6.1 295 5 297 165 -0.3 0 -0.1 -0.3 04/10/2006 22:50:00 8.5 1.3 12.6 5.3 8.5 1.5 13 5.7 7.3 1.5 11.8 3.8 300 9 286 165 -0.5 0.1 -0.1 -0.8 04/10/2006 23:00:00 9 1.4 12.6 5.7 9 1.4 12.6 5.3 7.4 1.4 11.1 3.8 295 8 292 165 -0.3 0.1 -0.1 -0.8 04/10/2006 23:10:00 11.4 1.2 14.1 7.2 11.5 1.3 14.1 7.6 9.4 1.5 13.3 5.3 293 7 290 165 -0.1 0 0.2 -0.5 04/10/2006 23:20:00 10.4 1 13 7.6 10.3 1 13 8 8.3 1.1 11.8 5.7 305 7 294 165 -0.2 0 -0.1 -0.5 04/10/2006 23:30:00 10.2 1.4 13.7 6.5 10.1 1.4 13.7 6.8 8.5 1.3 13.7 5.3 306 9 301 165 -0.3 0.1 -0.1 -0.5 04/10/2006 23:40:00 9.4 1.3 13 6.1 9.3 1.3 12.6 6.1 7.3 1.2 11.5 4.2 299 8 291 165 -0.2 0.1 0.2 -0.5 04/10/2006 23:50:00 8.2 2.1 11.8 3 8.1 2 11.8 2.6 6.8 1.9 10.7 1.9 297 12 288 165 -0.2 0.1 0.2 -0.3 04/11/2006 00:00:00 9.1 1.5 12.6 6.1 9 1.5 12.6 6.1 7.4 1.7 11.5 3.8 288 9 284 165 -0.2 0 -0.1 -0.3 04/11/2006 00:10:00 7.7 1.7 11.8 3.4 7.7 1.7 11.5 3.8 6 2 11.8 1.9 291 13 283 165 -0.2 0.1 -0.1 -0.3 04/11/2006 00:20:00 9.3 1.4 12.2 5.7 9.2 1.4 12.2 5.3 8.1 1.5 11.5 4.9 288 8 286 165 -0.2 0 -0.1 -0.3 04/11/2006 00:30:00 10.6 1.4 14.1 7.2 10.6 1.4 14.5 7.6 9.5 1.6 13.7 5.3 282 6 277 165 -0.3 0 -0.1 -0.3 04/11/2006 00:40:00 12.5 1.2 14.9 9.5 12.5 1.2 14.9 9.1 10.5 1.6 13.7 6.8 289 6 282 165 -0.1 0 0.2 -0.3 04/11/2006 00:50:00 12.8 1.3 16.1 8.8 12.8 1.4 16.4 8.8 10.2 1.6 14.9 6.8 294 6 289 165 0.1 0 0.2 -0.1 04/11/2006 01:00:00 12.7 2 16.4 8 12.6 2.1 16.4 8 10.4 2.1 15.3 5.7 291 6 286 165 0.1 0 0.2 -0.3 04/11/2006 01:10:00 11 1.5 13.7 6.1 10.8 1.4 13.7 6.8 9.1 1.6 13 4.2 291 7 285 165 -0.2 0 -0.1 -0.3 04/11/2006 01:20:00 11.1 1.2 14.5 8 11 1.3 14.5 7.6 9 1.6 13 4.6 293 7 291 165 0 0.1 0.2 -0.3 04/11/2006 01:30:00 11.4 1.1 14.5 8.4 11.3 1.1 14.5 8.4 9 1.2 13 6.5 296 7 291 165 0 0 0.2 -0.3 04/11/2006 01:40:00 10.7 1.5 14.1 6.5 10.5 1.4 13.7 6.1 8.5 1.4 12.2 4.2 297 7 292 165 0.1 0 0.2 -0.1 04/11/2006 01:50:00 8.9 1.5 11.8 4.6 8.7 1.5 11.8 4.9 7.4 1.5 11.1 3.4 295 8 294 165 -0.1 0 0.2 -0.3 04/11/2006 02:00:00 8.2 1.2 11.5 3.8 8.1 1.1 11.1 3.8 6.8 1.4 10.3 3 291 8 284 165 -0.2 0 -0.1 -0.3 04/11/2006 02:10:00 7.8 0.9 9.9 5.7 7.7 0.9 10.3 4.9 6.4 1.1 9.5 4.2 290 6 296 165 -0.2 0 -0.1 -0.3 04/11/2006 02:20:00 7.8 1 10.3 4.9 7.8 0.9 10.3 4.9 7 1 9.5 4.2 284 5 287 165 -0.2 0 -0.1 -0.5 04/11/2006 02:30:00 8.2 0.8 9.9 5.7 8.1 0.9 10.3 5.7 6.8 1.1 9.5 3.8 291 5 294 165 0 0 0.2 -0.1 04/11/2006 02:40:00 7.9 0.8 9.5 5.7 7.8 0.9 9.9 4.9 6.2 1 9.1 3.8 297 7 294 165 0.2 0.1 0.4 -0.1 04/11/2006 02:50:00 8.9 0.7 10.7 6.8 8.8 0.7 10.3 6.8 6.7 0.8 9.1 4.9 302 5 302 165 0.2 0 0.2 -0.1 04/11/2006 03:00:00 10 0.9 11.8 7.6 9.9 0.9 11.8 7.6 7.6 1.1 11.1 5.3 304 5 300 165 0.2 0 0.4 -0.1 04/11/2006 03:10:00 9.5 0.7 11.5 7.6 9.4 0.8 11.5 7.6 7.6 0.8 9.9 5.7 306 5 307 165 0.2 0 0.2 -0.1 04/11/2006 03:20:00 8.7 0.7 10.7 6.5 8.7 0.7 10.3 6.5 6.6 0.7 8.4 4.9 303 4 305 165 0.1 0 0.2 -0.1 04/11/2006 03:30:00 7.7 1.1 10.7 4.6 7.7 1.1 10.7 4.6 6 1 9.1 3.8 301 6 301 165 0.2 0 0.4 -0.1 04/11/2006 03:40:00 3.2 1.7 6.8 0.4 3.2 1.8 6.8 0.4 2.2 1.4 6.1 0.4 286 64 297 165 -0.3 0.1 -0.1 -0.5 04/11/2006 03:50:00 1.9 1.1 5.3 0.4 1.9 1.3 5.3 0.4 1.3 1.1 4.9 0.4 272 29 286 165 -0.3 0.1 -0.1 -0.8 04/11/2006 04:00:00 3.6 1.3 6.5 1.1 4 1.5 6.8 1.1 3.5 1.6 6.8 0.4 267 14 278 165 0.1 0.1 0.4 -0.3 04/11/2006 04:10:00 6.3 1.3 9.5 3.4 6.6 1.1 9.1 4.2 6.1 1 9.5 4.2 279 10 294 165 0.4 0 0.7 0.2 04/11/2006 04:20:00 5.6 1 8 3.4 6.6 0.8 9.1 4.2 6.1 0.8 8 4.2 272 6 277 165 0.5 0 0.9 0.2 04/11/2006 04:30:00 4.6 1.9 7.6 0.4 4.5 1.9 7.6 0.4 3.8 1.7 6.8 0.4 274 28 277 165 0.4 0 0.7 0.2 04/11/2006 04:40:00 2.9 1 4.9 0.4 3.2 1.3 6.5 0.4 2.5 1.3 5.3 0.4 247 23 255 165 0.3 0 0.7 0.2 04/11/2006 04:50:00 5.7 0.9 7.6 3 6 0.8 8 4.2 5.8 0.8 8 4.2 277 6 282 165 0.5 0.2 0.9 -0.1 04/11/2006 05:00:00 3.2 0.7 4.9 1.1 3.5 1 5.3 1.5 3.5 1 5.3 1.5 272 12 271 165 1.1 0.3 1.6 0.7 04/11/2006 05:10:00 3.6 1.2 5.7 1.1 3.9 1.3 6.5 1.5 3.8 1.3 6.5 1.5 260 11 241 165 1.4 0.1 1.6 1.1 04/11/2006 05:20:00 5.9 0.6 6.8 3.8 6 0.5 7.2 4.9 5.5 0.7 6.8 3.8 285 8 293 165 1.4 0.1 1.6 1.4 04/11/2006 05:30:00 4.6 1.1 6.5 2.3 4.8 1 6.5 3 4.5 0.8 6.1 3 282 9 294 165 1.4 0 1.6 1.4 04/11/2006 05:40:00 4.1 0.5 5.3 2.6 4.7 0.5 6.1 3.8 4.6 0.5 6.1 3.4 268 8 269 165 1.4 0 1.8 1.4 04/11/2006 05:50:00 3.1 0.8 5.3 1.5 3.7 0.6 4.9 1.9 3.3 0.8 4.9 1.1 258 9 245 165 1.3 0.1 1.6 0.9 04/11/2006 06:00:00 2.4 0.6 4.2 1.1 2.6 0.9 4.6 0.7 2 0.6 4.2 0.4 249 15 268 165 0.9 0.1 1.1 0.7 04/11/2006 06:10:00 1.9 0.8 3.8 0.4 1.7 0.9 3.8 0.4 1.4 0.8 3.4 0.4 268 20 288 165 0.8 0 0.9 0.7 04/11/2006 06:20:00 2.3 0.8 4.6 0.4 2.3 0.9 4.6 0.4 1.9 0.8 3.8 0.4 262 20 292 165 0.9 0 1.1 0.9 04/11/2006 06:30:00 1.9 0.7 3.4 0.4 2 1 4.6 0.4 1.8 0.9 4.6 0.4 266 17 270 165 1.1 0 1.4 0.9 04/11/2006 06:40:00 2.7 0.7 3.8 1.1 2.9 0.5 4.2 1.5 2.7 0.5 3.8 1.1 273 10 284 165 1.3 0 1.4 0.9 04/11/2006 06:50:00 1.8 0.7 4.2 0.4 1.6 0.8 3.8 0.4 1.6 0.7 3.8 0.4 224 58 287 165 1.2 0 1.4 0.9 04/11/2006 07:00:00 1.1 0.7 3.8 0.4 1.1 0.8 3.4 0.4 0.8 0.5 2.6 0.4 274 23 272 165 0.9 0 1.1 0.9 04/11/2006 07:10:00 1.1 0.6 2.3 0.4 0.9 0.6 2.3 0.4 1.1 0.6 2.3 0.4 189 69 146 165 1.1 0 1.4 0.9 04/11/2006 07:20:00 1 0.5 1.9 0.4 0.7 0.5 1.9 0.4 0.8 0.5 1.9 0.4 147 28 104 165 1.2 0.1 1.6 0.9 04/11/2006 07:30:00 1.4 0.5 2.3 0.4 1.1 0.7 2.3 0.4 1.5 0.6 2.3 0.4 133 6 139 165 1.4 0 1.6 1.4 04/11/2006 07:40:00 1 0.5 1.9 0.4 0.7 0.5 1.9 0.4 1 0.5 1.9 0.4 122 0 122 165 1.3 0 1.4 0.9 04/11/2006 07:50:00 0.6 0.6 2.3 0.4 0.6 0.6 2.3 0.4 0.6 0.6 2.6 0.4 150 45 147 165 1.7 0.2 1.8 1.4 04/11/2006 08:00:00 2.6 0.4 3.4 1.9 2.5 0.5 3.4 1.5 2.5 0.4 3.4 1.5 152 5 155 165 1.5 0.1 1.8 1.4 04/11/2006 08:10:00 3.5 0.3 4.2 2.6 3.3 0.3 3.8 2.6 3.5 0.3 4.2 2.6 163 6 162 165 1.4 0 1.6 1.4 04/11/2006 08:20:00 2.8 0.5 3.8 1.9 2.6 0.5 3.8 1.5 2.9 0.5 3.8 1.9 160 5 156 165 1.2 0 1.4 1.1 04/11/2006 08:30:00 2.6 0.4 3.4 1.9 2.3 0.4 3 1.5 2.4 0.4 3.4 1.5 166 6 162 165 1 0 1.4 0.9 04/11/2006 08:40:00 2.1 0.2 2.6 1.5 1.8 0.3 2.3 1.1 1.9 0.2 2.6 1.5 179 13 167 165 1.3 0.2 1.8 0.9 04/11/2006 08:50:00 2.3 0.3 3 1.5 2.1 0.3 2.6 1.1 2.3 0.3 3 1.9 186 4 179 165 2 0 2.3 1.6 04/11/2006 09:00:00 2.6 0.4 3.4 1.9 2.4 0.4 3.4 1.5 2.6 0.3 3.8 1.5 171 8 176 165 2.1 0 2.3 2.1 04/11/2006 09:10:00 2.1 0.5 3.8 1.5 1.8 0.6 3.4 0.7 2.2 0.5 3.8 1.5 169 5 167 165 2 0 2.3 1.8 04/11/2006 09:20:00 4.2 0.4 4.9 3 4 0.4 4.9 2.6 4.2 0.4 5.3 3 174 6 181 165 1.8 0 2.1 1.6 04/11/2006 09:30:00 4.8 0.5 5.7 3.4 4.6 0.5 5.3 3.4 4.9 0.4 5.7 3.8 177 5 173 165 1.5 0.1 1.8 1.4 04/11/2006 09:40:00 4.6 0.6 6.1 3.4 4.4 0.6 6.1 3.4 4.5 0.6 6.5 2.6 181 8 184 165 1.4 0 1.4 1.1 04/11/2006 09:50:00 4.6 0.7 6.1 2.6 4.6 0.8 6.5 2.6 4.6 0.7 6.5 2.6 195 13 197 165 1.5 0 1.6 1.4 04/11/2006 10:00:00 4.7 1 7.2 2.6 4.8 1 7.2 3 4.6 1 7.2 2.6 201 15 196 165 1.5 0.1 1.6 1.4 04/11/2006 10:10:00 5.2 0.6 7.2 3.8 5.2 0.7 7.2 3.4 5.3 0.7 7.2 3.8 194 7 205 165 0.9 0.1 1.4 0.7 04/11/2006 10:20:00 4.6 0.5 6.1 3.4 4.4 0.5 5.7 3.4 4.8 0.6 6.5 3 192 5 196 165 0.4 0.1 0.9 0.2 04/11/2006 10:30:00 3.6 0.4 4.9 2.6 3.5 0.4 4.9 2.6 3.7 0.4 4.9 2.6 194 5 196 165 0.2 0 0.2 -0.1 04/11/2006 10:40:00 3.2 0.4 4.2 2.3 3.1 0.4 3.8 1.9 3.3 0.4 4.2 2.3 178 8 185 165 0.1 0 0.2 -0.1 04/11/2006 10:50:00 2.3 0.4 3 1.5 2.1 0.4 3 1.1 2.4 0.4 3.4 1.5 166 6 172 165 0 0 0.2 -0.1 04/11/2006 11:00:00 2.1 0.2 2.6 1.5 1.8 0.3 2.6 1.1 2.1 0.3 2.6 1.5 162 2 160 165 0.1 0 0.2 -0.1 04/11/2006 11:10:00 2.3 0.3 3 1.5 2.1 0.3 2.6 1.1 2.4 0.2 3 1.5 156 5 151 165 0.1 0 0.2 -0.1 04/11/2006 11:20:00 2.6 0.2 3 1.9 2.5 0.2 3 1.9 2.6 0.2 3 1.9 149 3 148 165 0.2 0 0.2 0.2 04/11/2006 11:30:00 3.5 0.6 4.9 2.3 3.5 0.6 4.9 2.3 3.3 0.5 4.6 2.3 147 4 147 165 0.2 0 0.4 0.2 04/11/2006 11:40:00 3.9 0.4 4.6 3 3.8 0.4 4.6 2.6 3.7 0.3 4.6 3 148 5 150 165 0.4 0 0.7 0.2 04/11/2006 11:50:00 3.4 0.5 4.2 1.9 3.4 0.5 4.2 1.9 3.4 0.5 4.2 2.3 146 6 147 165 0.7 0 0.9 0.4 04/11/2006 12:00:00 3.7 0.5 4.9 2.6 3.8 0.6 4.9 2.6 3.6 0.6 4.9 2.3 134 5 135 165 0.8 0 0.9 0.7 04/11/2006 12:10:00 4.4 0.7 6.5 3.4 4.4 0.6 6.5 3.4 4.3 0.6 6.5 3 142 5 147 165 0.8 0 0.9 0.9 04/11/2006 12:20:00 6.2 0.7 8.4 4.6 6.2 0.7 8.4 4.6 6 0.6 7.6 4.2 140 8 147 165 0.9 0 1.1 0.7 04/11/2006 12:30:00 5.2 0.8 7.6 3 5.1 0.8 7.2 3 5.1 0.7 7.2 3 158 8 157 165 0.8 0 1.1 0.9 04/11/2006 12:40:00 5.8 0.7 7.6 4.2 5.7 0.6 7.2 4.2 5.9 0.7 7.6 4.6 158 12 170 165 0.9 0 1.1 0.9 04/11/2006 12:50:00 5.2 0.6 6.5 3.8 5.1 0.6 6.5 3.8 5.2 0.6 6.8 3.4 152 13 156 165 0.9 0 1.1 0.9 04/11/2006 13:00:00 4.4 0.7 5.7 2.3 4.3 0.6 5.7 2.6 4.4 0.6 6.1 3 156 11 157 165 1.1 0 1.4 0.9 04/11/2006 13:10:00 5.6 0.8 8 4.2 5.5 0.8 8 4.2 5.5 0.7 8 3.8 154 8 148 165 1.1 0 1.4 0.9 04/11/2006 13:20:00 5.1 0.8 7.6 3 5.1 0.7 7.2 3 5.1 0.7 7.2 3 154 9 176 165 1.1 0 1.4 0.9 04/11/2006 13:30:00 5.4 0.5 7.2 3.8 5.3 0.5 7.2 3.8 5.4 0.5 7.2 4.2 151 7 153 165 0.9 0 1.4 0.9 04/11/2006 13:40:00 7 1.1 9.9 4.9 7 1.1 9.9 4.9 6.9 1.1 9.9 5.3 154 8 164 165 1.1 0.1 1.4 0.9 04/11/2006 13:50:00 9.1 1 11.5 6.8 9.1 1 11.5 6.8 9 1.2 11.5 6.1 162 5 165 165 1.5 0 1.6 1.4 04/11/2006 14:00:00 11.3 0.8 13 9.5 11.4 0.8 13 9.1 11.4 1 13.3 8.8 165 14 164 165 1.7 0 1.8 1.6 04/11/2006 14:10:00 12 0.6 13.3 10.7 12.2 0.6 13.7 10.3 12.4 0.6 13.7 10.7 166 15 165 165 1.5 0 1.6 1.4 04/11/2006 14:20:00 13.9 0.8 16.1 11.5 14 0.7 16.1 11.5 14.3 0.9 16.4 12.2 165 8 165 165 1.5 0 1.6 1.4 04/11/2006 14:30:00 13.5 0.8 15.3 11.1 13.6 0.8 15.3 11.5 13.9 1 16.1 10.7 165 10 164 165 1.6 0 1.8 1.4 04/11/2006 14:40:00 13.2 0.8 15.3 10.7 13.3 0.8 15.3 10.7 13.6 0.9 15.6 10.7 164 6 162 165 1.5 0 1.6 1.4 04/11/2006 14:50:00 12 1.2 14.9 8.8 12 1.2 14.9 8.8 12.2 1.3 15.6 8.8 162 13 164 165 1.4 0 1.6 1.4 04/11/2006 15:00:00 9.8 1.1 13 7.6 9.8 1.2 13 7.6 9.8 1.1 13 7.6 160 6 160 165 1.4 0 1.6 1.4 04/11/2006 15:10:00 10.1 1.4 13 6.8 10.1 1.3 13 7.2 10.3 1.4 13.7 6.8 161 6 164 165 1.4 0 1.6 1.4 04/11/2006 15:20:00 9.1 1 12.2 6.8 9.2 0.9 12.2 6.8 9.2 1 12.2 6.8 158 7 165 165 1.4 0 1.6 1.4 04/11/2006 15:30:00 9.2 0.7 11.1 7.2 9.3 0.7 11.1 7.6 9.4 0.8 11.5 6.8 161 5 164 165 1.4 0 1.6 1.4 04/11/2006 15:40:00 9.3 0.6 10.7 7.6 9.4 0.6 10.7 7.6 9.3 0.7 11.1 7.6 162 4 165 165 1.4 0 1.6 1.4 04/11/2006 15:50:00 9.8 0.6 11.5 8.4 10 0.6 11.5 8 10 0.7 12.2 6.8 168 8 174 165 1.5 0 1.6 1.4 04/11/2006 16:00:00 10.5 0.6 11.8 8.4 10.6 0.6 11.8 8.8 10.7 0.7 12.6 8.8 165 5 169 165 1.4 0.1 1.6 1.4 04/11/2006 16:10:00 9.4 0.6 11.1 8 9.5 0.6 11.1 8 9.7 0.7 11.5 7.2 162 2 163 165 1.3 0 1.4 1.1 04/11/2006 16:20:00 8.9 0.5 9.9 7.6 9 0.5 10.3 8 9.1 0.5 10.7 7.6 162 10 165 165 1.3 0 1.4 1.1 04/11/2006 16:30:00 9.6 0.8 11.1 6.8 9.6 0.8 11.1 6.8 10.1 0.8 12.6 7.6 155 5 155 165 1.2 0 1.4 1.1 04/11/2006 16:40:00 11.4 0.7 13 9.1 11.4 0.7 13 9.1 11.8 0.7 13.3 9.5 163 1 163 165 1.2 0 1.4 1.1 04/11/2006 16:50:00 12.3 0.5 13.3 11.1 12.3 0.5 13.3 11.1 12.6 0.6 14.1 9.9 163 0 163 165 1.2 0 1.4 1.1 04/11/2006 17:00:00 12.4 0.5 13.7 10.7 12.4 0.5 13.7 10.7 12.7 0.6 14.1 10.7 163 0 163 165 1.2 0 1.4 0.9 04/11/2006 17:10:00 11.8 0.7 13 9.5 11.8 0.7 13 9.9 12.1 0.8 13.7 9.9 163 0 163 165 1.1 0 1.4 0.9 04/11/2006 17:20:00 10.8 0.7 12.2 9.5 10.9 0.6 12.2 9.1 11 0.9 12.6 8.4 163 0 163 165 1 0 1.4 0.9 04/11/2006 17:30:00 9.9 0.6 11.1 8 9.9 0.6 11.1 8 9.8 0.7 11.1 7.2 163 0 163 165 1.1 0 1.4 0.9 04/11/2006 17:40:00 9.5 0.6 11.1 7.6 9.6 0.6 11.5 8 9.4 0.7 11.1 7.2 163 0 163 165 0.9 0 1.1 0.9 04/11/2006 17:50:00 9.2 0.6 10.3 7.6 9.4 0.7 11.1 7.6 9.1 0.7 10.7 7.2 163 0 163 165 1.1 0 1.4 0.9 04/11/2006 18:00:00 8.5 0.6 9.9 6.5 8.6 0.6 9.9 6.1 8.2 0.7 9.9 6.1 163 0 163 165 1.1 0 1.4 0.9 04/11/2006 18:10:00 8.5 0.6 9.9 6.5 8.5 0.6 9.9 6.5 8.2 0.6 9.5 6.1 163 0 163 165 0.9 0 1.1 0.9 04/11/2006 18:20:00 7 0.9 8.8 5.3 7.1 0.9 8.8 5.3 6.8 0.8 8.4 4.9 163 0 163 165 0.9 0 1.1 0.9 04/11/2006 18:30:00 5.7 0.5 6.8 4.6 5.9 0.5 7.2 4.6 5.7 0.6 6.8 3.8 163 0 163 165 0.9 0 1.1 0.9 04/11/2006 18:40:00 5.7 0.5 6.8 4.6 5.8 0.5 6.8 4.6 5.6 0.5 7.2 4.2 163 0 163 165 1.1 0 1.4 0.9 04/11/2006 18:50:00 6.4 0.6 7.6 4.2 6.6 0.6 7.6 4.6 6.2 0.7 7.6 3.8 163 0 163 165 1.1 0 1.4 0.9 04/11/2006 19:00:00 5.4 0.6 6.8 4.2 5.5 0.6 6.8 3.8 5.2 0.8 6.5 2.6 163 0 163 165 1.2 0 1.4 1.1 04/11/2006 19:10:00 5.9 0.6 7.2 4.2 5.9 0.6 7.2 4.2 5.9 0.6 7.2 4.2 163 0 163 165 1.2 0 1.4 0.9 04/11/2006 19:20:00 6 0.4 6.8 4.9 6 0.4 6.8 4.9 5.9 0.5 6.8 3.8 163 0 163 165 1.4 0 1.6 1.4 04/11/2006 19:30:00 6.6 0.5 8 5.3 6.4 0.4 7.6 5.3 6.6 0.5 8 5.3 163 0 163 165 1.4 0 1.6 1.4 04/11/2006 19:40:00 6.7 0.6 7.6 4.9 6.4 0.5 7.2 4.9 6.6 0.6 8 4.9 163 0 163 165 1.4 0 1.6 1.4 04/11/2006 19:50:00 6.3 0.7 8 4.2 6 0.6 7.2 3.8 6.3 0.7 8 4.2 163 0 163 165 1.4 0 1.6 1.4 04/11/2006 20:00:00 7.2 0.5 8.4 5.7 7.2 0.5 8.4 5.3 7.2 0.5 8.8 5.3 163 0 163 165 1.6 0 1.6 1.4 04/11/2006 20:10:00 7.4 0.4 8 6.1 7.3 0.4 8 6.1 7.4 0.5 8.4 5.3 163 0 163 165 1.7 0 1.8 1.4 04/11/2006 20:20:00 5.6 0.6 7.2 4.2 5.7 0.6 7.2 4.2 5.8 0.7 7.6 4.2 163 0 163 165 1.7 0 1.8 1.4 04/11/2006 20:30:00 5.4 0.4 6.8 4.6 5.6 0.4 7.2 4.6 5.8 0.3 6.8 4.9 163 0 163 165 1.7 0 1.8 1.6 04/11/2006 20:40:00 5.4 0.4 6.1 4.2 5.7 0.5 6.8 4.6 5.8 0.5 6.8 4.6 163 0 163 165 1.7 0 1.8 1.6 04/11/2006 20:50:00 4.9 0.5 6.1 3.8 5 0.7 6.5 3.8 5.2 0.7 6.8 3.8 163 0 163 165 1.7 0 1.8 1.6 04/11/2006 21:00:00 4.4 0.5 5.7 3 4.3 0.5 5.3 3 4.6 0.4 6.1 3.8 163 0 163 165 1.7 0 1.8 1.6 04/11/2006 21:10:00 4.2 0.6 5.7 3 4.2 0.6 5.7 3 4.4 0.5 5.7 3 163 0 162 165 1.8 0 1.8 1.6 04/11/2006 21:20:00 3 0.5 4.2 1.9 2.4 0.8 4.2 0.7 3.5 0.4 4.2 2.6 162 0 162 165 1.8 0 1.8 1.6 04/11/2006 21:30:00 2.9 0.4 3.8 2.3 2.6 0.4 3.4 1.9 3.7 0.3 4.6 3 162 0 162 165 1.8 0 1.8 1.6 04/11/2006 21:40:00 2.3 1.3 4.2 0.4 1.9 1.2 3.8 0.4 2.9 1.2 4.6 0.4 162 0 162 165 1.8 0 1.8 1.6 04/11/2006 21:50:00 0.4 0.1 1.1 0.4 0.4 0 0.4 0.4 0.8 0.4 1.5 0.4 162 0 162 165 1.9 0 2.1 1.8 04/11/2006 22:00:00 1.6 0.9 3 0.4 0.8 0.8 2.6 0.4 2.1 0.8 3.4 0.4 162 0 162 165 2 0 2.3 1.8 04/11/2006 22:10:00 2.3 0.5 3.8 1.1 1.6 0.7 3.4 0.4 2.4 0.6 3.8 1.1 162 0 162 165 2.1 0 2.3 1.8 04/11/2006 22:20:00 3.1 0.4 4.2 1.9 2.7 0.5 3.8 1.5 3.2 0.4 4.2 1.9 158 13 161 165 2.2 0 2.3 2.1 04/11/2006 22:30:00 1.7 0.8 3 0.4 1.2 0.8 2.6 0.4 2.1 0.7 3.8 0.4 149 17 118 165 2.1 0 2.3 1.8 04/11/2006 22:40:00 2.4 0.8 4.2 1.1 1.6 1 3.8 0.4 2.5 0.8 4.2 1.1 144 10 151 165 2.2 0 2.3 1.8 04/11/2006 22:50:00 3.3 0.4 4.2 2.3 2.8 0.4 3.8 1.9 3.5 0.4 4.6 2.6 153 6 151 165 2.3 0 2.6 2.3 04/11/2006 23:00:00 3 0.5 3.8 1.9 2.4 0.7 3.4 1.1 3.2 0.5 4.2 2.3 161 4 164 165 2.3 0 2.6 2.1 04/11/2006 23:10:00 3 0.4 3.8 1.9 2.7 0.4 3.8 1.9 3.4 0.4 4.6 2.3 163 6 153 165 2.4 0 2.6 2.3 04/11/2006 23:20:00 1.8 0.9 3 0.4 1.7 0.7 3 0.4 2.4 0.6 3.4 1.1 163 3 162 165 2.4 0 2.6 2.3 04/11/2006 23:30:00 1.2 0.5 2.3 0.4 0.4 0.2 1.5 0.4 1.7 0.3 2.3 0.7 164 2 165 165 2.4 0 2.6 2.3 04/11/2006 23:40:00 1.4 0.2 1.9 1.1 1 0.2 1.5 0.7 1.4 0.3 1.9 0.7 163 1 162 165 2.4 0 2.6 2.3 04/11/2006 23:50:00 2.2 0.4 3 1.5 1.8 0.4 2.6 1.1 2.5 0.4 3.4 1.5 162 1 162 165 2.5 0 2.8 2.6 04/12/2006 00:00:00 3 0.3 3.4 1.9 2.6 0.3 3.4 1.5 3.2 0.3 3.8 2.6 158 5 162 165 2.6 0 2.8 2.6 04/12/2006 00:10:00 2.4 0.3 3 1.5 2.2 0.3 3 1.5 2.5 0.3 3 1.9 152 5 153 165 2.7 0 2.8 2.6 04/12/2006 00:20:00 2.8 0.2 3 2.3 2.6 0.2 3 2.3 2.8 0.2 3.4 2.3 158 2 157 165 2.7 0 2.8 2.6 04/12/2006 00:30:00 2.4 0.5 3.4 1.5 2 0.5 3 1.1 2.5 0.4 3.4 1.5 161 3 160 165 2.8 0 3 2.6 04/12/2006 00:40:00 2.2 0.4 3 1.1 1.8 0.4 2.6 0.7 2.3 0.4 3 1.5 164 9 156 165 2.8 0 2.8 2.6 04/12/2006 00:50:00 1 0.6 2.3 0.4 0.7 0.5 1.9 0.4 1.1 0.7 2.6 0.4 184 9 170 165 2.7 0 2.8 2.6 04/12/2006 01:00:00 0.4 0 0.7 0.4 0.4 0 0.4 0.4 0.4 0.1 1.1 0.4 185 4 200 165 2.7 0 2.8 2.6 04/12/2006 01:10:00 0.5 0.2 1.1 0.4 0.4 0.1 0.7 0.4 0.5 0.2 1.1 0.4 144 33 118 165 2.6 0 2.8 2.6 04/12/2006 01:20:00 1.4 0.4 2.3 0.4 1 0.5 1.9 0.4 1.4 0.3 1.9 0.7 119 1 118 165 2.6 0 2.8 2.6 04/12/2006 01:30:00 2.1 0.4 3 1.1 1.9 0.4 2.6 0.7 2 0.5 3 1.1 105 9 102 165 2.5 0 2.8 2.6 04/12/2006 01:40:00 2.4 0.5 3.4 1.5 2.2 0.5 3 1.1 2.4 0.5 3.4 1.1 104 5 104 165 2.7 0 2.8 2.6 04/12/2006 01:50:00 2 0.7 3.4 0.7 1.9 0.7 3.4 0.4 2.1 0.6 3.4 1.1 115 5 106 165 2.6 0 2.8 2.6 04/12/2006 02:00:00 2 0.4 2.6 0.7 1.9 0.5 2.6 0.7 2 0.4 2.6 1.1 120 4 118 165 2.6 0 2.8 2.6 04/12/2006 02:10:00 1.6 0.3 2.3 0.7 1.3 0.3 2.3 0.7 1.8 0.3 2.6 1.1 155 14 165 165 2.5 0 2.8 2.3 04/12/2006 02:20:00 2.4 0.2 2.6 1.9 2.1 0.2 2.6 1.5 2.5 0.2 3 1.9 162 7 165 165 2.5 0 2.8 2.6 04/12/2006 02:30:00 1.8 0.2 2.3 1.5 1.5 0.2 1.9 1.1 2.1 0.2 2.6 1.9 170 8 162 165 2.5 0 2.8 2.3 04/12/2006 02:40:00 1.7 0.2 2.3 1.1 1.4 0.2 1.9 0.7 1.9 0.3 2.6 1.1 172 10 173 165 2.5 0 2.6 2.6 04/12/2006 02:50:00 1.1 0.4 1.9 0.4 0.7 0.4 1.9 0.4 1.5 0.3 2.3 0.7 157 5 163 165 2.4 0 2.6 2.3 04/12/2006 03:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0.1 1.1 0.4 153 0 165 165 2.4 0 2.6 2.3 04/12/2006 03:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 153 0 165 165 2.4 0 2.6 2.3 04/12/2006 03:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 153 0 165 165 2.3 0 2.6 2.3 04/12/2006 03:30:00 0.8 0.4 1.5 0.4 0.6 0.4 1.9 0.4 1.2 0.5 1.9 0.4 20 79 342 165 2.3 0 2.6 2.3 04/12/2006 03:40:00 0.6 0.3 1.5 0.4 0.5 0.2 1.1 0.4 1.1 0.5 1.9 0.4 337 9 339 165 2.3 0 2.6 2.1 04/12/2006 03:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.7 0.4 286 4 165 165 2.4 0 2.6 2.3 04/12/2006 04:00:00 0.5 0.2 1.1 0.4 0.4 0 0.7 0.4 1.1 0.5 1.9 0.4 312 28 347 165 2.5 0 2.6 2.3 04/12/2006 04:10:00 0.5 0.4 1.5 0.4 0.5 0.3 1.5 0.4 1.4 0.3 2.3 0.7 340 6 343 165 2.5 0 2.8 2.6 04/12/2006 04:20:00 2 0.3 2.6 1.1 1.2 0.5 2.3 0.4 2.4 0.3 3 1.9 343 6 349 165 2.5 0 2.6 2.3 04/12/2006 04:30:00 1.7 0.2 2.3 1.1 1 0.5 2.3 0.4 2.3 0.2 2.6 1.9 349 2 349 165 2.4 0 2.6 2.3 04/12/2006 04:40:00 1.8 0.5 3 1.1 1.8 0.5 3 0.7 2.2 0.4 3.4 1.5 322 15 310 165 2.4 0 2.6 2.1 04/12/2006 04:50:00 2.1 0.5 3.4 0.7 2.3 0.5 3.4 0.7 2.5 0.5 3.4 1.1 309 7 312 165 2.5 0 2.6 2.3 04/12/2006 05:00:00 1.1 0.6 2.3 0.4 1.1 0.7 2.6 0.4 1.4 0.5 2.6 0.4 301 8 301 165 2.4 0 2.6 2.3 04/12/2006 05:10:00 0.5 0.2 1.5 0.4 0.4 0.1 1.1 0.4 1.1 0.4 2.3 0.4 334 6 344 165 2.4 0 2.6 2.3 04/12/2006 05:20:00 0.5 0.3 1.9 0.4 0.5 0.3 1.9 0.4 1.2 0.6 2.6 0.4 300 12 283 165 2.4 0 2.6 2.3 04/12/2006 05:30:00 0.4 0.2 1.1 0.4 0.4 0 0.4 0.4 0.6 0.4 1.9 0.4 276 12 261 165 2.6 0 2.8 2.3 04/12/2006 05:40:00 0.5 0.5 2.6 0.4 0.4 0.3 2.3 0.4 0.6 0.5 3 0.4 235 58 353 165 2.7 0 2.8 2.6 04/12/2006 05:50:00 0.5 0.3 1.9 0.4 0.4 0 0.7 0.4 0.7 0.5 1.9 0.4 190 102 133 165 2.7 0 2.8 2.6 04/12/2006 06:00:00 1.1 0.5 3 0.4 0.9 0.5 3 0.4 1.5 0.5 3.8 0.4 149 58 330 165 2.5 0 2.8 2.6 04/12/2006 06:10:00 1.7 0.8 3 0.4 1.8 0.9 3.8 0.4 1.8 0.8 3.4 0.4 279 58 301 165 2.9 0 3 2.6 04/12/2006 06:20:00 0.7 0.6 2.6 0.4 0.8 0.6 2.6 0.4 1 0.6 2.6 0.4 289 82 294 165 2.8 0 3 2.8 04/12/2006 06:30:00 0.7 0.5 1.9 0.4 0.5 0.4 1.9 0.4 1.3 0.5 2.3 0.4 150 24 138 165 2.6 0.1 2.8 2.3 04/12/2006 06:40:00 2.6 1.7 4.9 0.4 2.7 1.7 4.9 0.4 2.7 1.7 5.3 0.4 303 76 283 165 2.7 0.1 3 2.3 04/12/2006 06:50:00 3.6 0.8 5.3 1.5 3.9 0.6 5.3 2.3 3.4 0.6 4.6 0.4 281 8 292 165 3.2 0 3.5 2.8 04/12/2006 07:00:00 3 0.6 4.6 1.1 3.2 0.6 4.6 1.5 2.5 0.7 4.2 0.4 286 8 282 165 3.2 0.2 3.8 2.8 04/12/2006 07:10:00 1.5 0.7 3 0.4 1.7 0.7 3.4 0.4 1.7 0.5 3 0.7 292 6 293 165 3.8 0 4 3.5 04/12/2006 07:20:00 1.3 0.8 3 0.4 1.9 1.2 3.8 0.4 1.8 1.1 3.4 0.4 266 16 248 165 4 0 4.3 3.8 04/12/2006 07:30:00 2.6 1.2 4.6 0.4 3.3 1.2 4.9 0.4 2.9 1.2 4.9 0.4 271 16 283 165 4.3 0 4.5 4 04/12/2006 07:40:00 2.6 0.9 4.6 0.7 3.7 0.6 4.9 1.9 3.3 0.8 5.3 1.9 263 9 278 165 4.2 0.2 4.5 3.8 04/12/2006 07:50:00 3.5 0.7 4.9 1.1 4 0.6 4.9 1.5 3.8 0.8 4.9 1.1 275 8 274 165 4.2 0 4.5 4.3 04/12/2006 08:00:00 2.9 0.7 5.3 1.1 3 0.8 5.3 1.1 2.5 0.6 4.2 0.7 290 13 282 165 4.2 0 4.5 4.3 04/12/2006 08:10:00 4.8 1.2 8.8 2.6 4.9 1.2 8.4 3 4 1.1 8.4 2.6 291 7 285 165 4.2 0 4.5 4.3 04/12/2006 08:20:00 6.9 0.5 8.4 5.3 6.9 0.5 8.4 5.3 5.2 0.6 7.2 3.8 293 4 301 165 4.3 0 4.5 4.3 04/12/2006 08:30:00 6.5 0.8 8.4 4.6 6.5 0.8 8.4 4.2 4.8 0.7 6.5 2.6 297 5 301 165 4.3 0 4.5 4.3 04/12/2006 08:40:00 6.5 0.6 8 4.9 6.4 0.6 8 4.6 4.9 0.6 6.5 2.6 302 4 300 165 4.4 0 4.5 4.3 04/12/2006 08:50:00 2.8 1.3 5.7 0.4 2.7 1.3 5.3 0.4 1.8 1.1 4.6 0.4 292 39 298 165 4 0.3 4.5 3.5 04/12/2006 09:00:00 4.1 0.5 4.9 2.3 4.1 0.5 5.3 2.3 3.6 0.9 6.1 0.4 289 7 276 165 3.8 0.3 4.3 3.3 04/12/2006 09:10:00 2.7 1 4.9 0.7 3 0.9 4.9 1.1 2.5 1 4.6 0.4 277 13 296 165 4.3 0 4.5 4.3 04/12/2006 09:20:00 3.3 0.9 4.6 1.1 3.5 0.8 4.9 1.5 3.2 0.8 4.9 1.5 281 9 282 165 4.3 0 4.5 4 04/12/2006 09:30:00 4 0.4 4.9 3 4.1 0.4 4.9 3 3.4 0.5 4.9 1.9 292 5 288 165 4.4 0 4.5 4.3 04/12/2006 09:40:00 3.4 0.4 4.2 2.3 3.4 0.4 4.2 2.3 2.8 0.4 3.8 1.5 298 6 294 165 4.5 0 4.8 4.5 04/12/2006 09:50:00 3.6 0.4 4.6 2.6 3.6 0.4 4.6 2.3 3.2 0.5 4.6 1.9 288 4 292 165 4.5 0 4.5 4.5 04/12/2006 10:00:00 3.5 0.4 4.6 2.3 3.6 0.4 4.9 2.6 3.1 0.5 4.2 1.9 287 5 288 165 4.6 0 4.8 4.5 04/12/2006 10:10:00 3.9 0.6 5.3 1.9 3.9 0.6 5.3 1.9 3.2 0.6 4.6 1.1 293 8 286 165 4.8 0 5 4.5 04/12/2006 10:20:00 3.1 0.8 5.3 1.1 3.2 0.9 4.9 1.1 2.8 0.8 4.6 0.4 299 15 300 165 5 0 5.2 4.5 04/12/2006 10:30:00 1.5 0.8 4.2 0.4 1.5 0.9 4.2 0.4 1.7 0.6 3.4 0.4 296 19 297 165 4.8 0 5 4.5 04/12/2006 10:40:00 2.9 1.3 6.5 0.7 2.9 1.4 6.5 0.4 2.8 1 5.7 1.1 310 23 305 165 4.7 0 5 4.5 04/12/2006 10:50:00 3.6 0.8 5.3 1.9 3.5 0.8 5.3 1.9 3.5 0.8 5.3 1.5 312 13 327 165 4.8 0 5 4.5 04/12/2006 11:00:00 4.1 1 6.1 1.5 4.1 1 6.8 1.5 3.7 0.8 5.7 1.9 305 11 312 165 4.7 0 4.8 4.5 04/12/2006 11:10:00 5.3 0.6 7.2 3.4 5.2 0.6 7.2 3.4 4.7 0.7 7.2 2.6 310 11 326 165 4.8 0 5 4.8 04/12/2006 11:20:00 7 0.8 9.9 4.6 6.9 0.8 9.5 4.6 6.8 0.9 9.5 4.6 311 5 310 165 4.8 0.1 5 4.5 04/12/2006 11:30:00 7.6 0.9 9.5 5.3 7.5 0.9 9.5 5.3 6.7 1.1 9.1 4.2 307 6 309 165 4.6 0 4.8 4.5 04/12/2006 11:40:00 7.7 0.8 9.1 4.9 7.5 0.8 8.8 4.9 6.7 1.1 8.8 3.8 307 6 312 165 4.8 0 5 4.5 04/12/2006 11:50:00 7.2 0.7 9.5 4.9 7 0.7 8.8 4.6 6.6 0.8 9.1 4.2 310 6 303 165 4.8 0 5 4.5 04/12/2006 12:00:00 7.7 0.7 9.5 5.7 7.5 0.7 9.1 5.7 7.2 0.8 9.1 4.6 313 6 305 165 4.8 0 5 4.5 04/12/2006 12:10:00 7.1 0.9 9.9 4.9 7 0.9 9.5 4.9 6.4 1 9.1 3.8 311 8 310 165 4.7 0.1 5 4.3 04/12/2006 12:20:00 6.9 0.8 8.8 4.6 6.8 0.7 8.4 4.6 6.2 1.1 8.4 3.8 307 7 308 165 4.4 0 4.8 4.3 04/12/2006 12:30:00 8 1 10.7 4.9 7.8 1 10.3 5.3 7 1.3 10.3 3.8 307 7 315 165 4.3 0 4.5 4.3 04/12/2006 12:40:00 9.4 0.6 10.7 6.8 9.3 0.7 10.7 6.8 8.8 0.8 11.1 6.5 311 5 315 165 4.4 0 4.8 4.3 04/12/2006 12:50:00 9.3 0.7 11.5 6.8 9.2 0.8 11.5 6.8 8.5 0.9 10.3 6.5 309 5 302 165 4.3 0 4.5 4 04/12/2006 13:00:00 9.4 0.6 10.7 7.6 9.4 0.7 10.7 6.8 8.5 1.2 11.1 5.3 307 5 309 165 4.3 0.1 4.5 3.8 04/12/2006 13:10:00 9.3 0.7 11.1 7.6 9.4 0.7 11.1 7.2 8.2 1.3 11.1 4.9 303 6 304 165 3.9 0 4.3 3.5 04/12/2006 13:20:00 9.6 0.7 11.5 8 9.6 0.7 11.5 7.6 8.3 1.3 11.8 5.7 305 6 315 165 4.1 0.1 4.5 3.5 04/12/2006 13:30:00 9.6 0.6 11.1 7.6 9.6 0.6 11.1 8 8.3 1 11.5 5.7 305 5 304 165 4.4 0 4.8 4 04/12/2006 13:40:00 11.2 1 13.3 8.4 11.1 1 13 8 9.8 1.3 12.2 6.5 305 4 305 165 4.1 0 4.3 3.8 04/12/2006 13:50:00 10.5 0.8 12.6 8 10.6 0.8 12.2 8.4 8.3 1 11.1 6.1 298 6 292 165 4.4 0.1 4.8 4.3 04/12/2006 14:00:00 8.9 1.3 11.8 6.1 8.9 1.3 11.8 6.1 7.2 1.2 10.7 4.6 297 7 298 165 4.8 0.1 5 4.3 04/12/2006 14:10:00 8 0.7 9.5 6.1 8 0.8 9.5 6.1 6.4 0.9 8.8 4.6 296 6 292 165 5 0.2 5.2 4.5 04/12/2006 14:20:00 7.6 1 9.5 4.2 7.6 1.1 9.5 3.8 6.2 1.1 9.5 3.8 297 9 297 165 4.7 0.1 5 4.5 04/12/2006 14:30:00 8.6 0.8 11.1 6.5 8.6 0.8 11.1 6.8 6.8 1.1 10.7 4.9 299 7 307 165 4.4 0.1 4.8 3.8 04/12/2006 14:40:00 7.7 1.3 11.5 4.6 7.7 1.3 11.8 4.6 6.4 1.6 12.6 3.8 294 9 283 165 4.6 0.1 5 4.3 04/12/2006 14:50:00 7.9 1 10.7 5.3 8 1 10.7 5.7 6.6 1.1 10.3 4.6 294 9 286 165 4.8 0.2 5.2 4.3 04/12/2006 15:00:00 7.2 1.1 10.3 4.6 7.2 1.1 10.3 4.6 6.5 1.2 9.5 3 307 8 310 165 5.1 0.2 5.5 4.5 04/12/2006 15:10:00 6.9 1 10.3 4.2 6.8 1 9.9 3.8 6.3 1.2 10.3 3 310 9 324 165 4.9 0.2 5.2 4.3 04/12/2006 15:20:00 10.1 2.7 16.8 5.3 10 2.8 16.4 5.3 9.1 2.8 16.4 4.2 302 16 293 165 4.7 0.3 5.2 4 04/12/2006 15:30:00 10.3 1.6 14.9 7.2 10.3 1.6 14.5 7.2 9 1.5 13.3 5.3 297 12 296 165 4.1 0.1 4.5 3.5 04/12/2006 15:40:00 8.2 1.3 11.5 3.8 8.2 1.3 11.5 4.6 7.5 1.4 11.1 3.8 304 11 290 165 4.4 0.2 4.8 3.8 04/12/2006 15:50:00 8.1 1 10.3 5.7 8.1 1 10.7 5.7 7 1.2 9.5 3.8 300 10 288 165 4.3 0.2 4.8 3.8 04/12/2006 16:00:00 8 1 11.1 5.3 8.2 1.1 10.3 5.3 7.5 1.3 10.3 4.6 283 10 290 165 4 0.1 4.5 3.5 04/12/2006 16:10:00 10.3 1.3 12.6 6.1 10.3 1.3 12.6 6.5 8.3 1.4 12.6 5.3 302 7 307 165 3.6 0.1 4 3.3 04/12/2006 16:20:00 10.7 1 13.7 7.6 10.7 1 14.1 7.6 9 1.3 12.2 6.1 305 7 294 165 3.8 0.2 4.3 3.3 04/12/2006 16:30:00 10.1 1.1 13 7.2 10 1.1 13 7.6 9.1 1.3 12.2 6.1 309 8 304 165 4 0.1 4.3 3.5 04/12/2006 16:40:00 11.1 1.4 15.3 7.2 11 1.3 14.9 7.6 9.5 1.7 14.1 5.7 307 7 318 165 4.1 0.1 4.3 3.8 04/12/2006 16:50:00 11.2 1.3 14.9 7.2 11.1 1.3 14.9 8 9.5 1.8 14.5 6.1 307 9 318 165 3.8 0 4.3 3.5 04/12/2006 17:00:00 14 1.3 17.9 11.1 14 1.4 17.9 10.7 10.9 1.6 17.6 7.2 303 6 300 165 3.5 0 3.8 3.5 04/12/2006 17:10:00 13.8 1.3 16.8 9.9 13.8 1.3 17.2 9.9 11 1.8 15.6 7.6 302 6 301 165 3.2 0.1 3.5 3 04/12/2006 17:20:00 14.5 1.5 18.7 9.5 14.5 1.5 18.7 9.5 11.3 1.7 16.1 7.2 295 7 286 165 3 0 3.3 2.8 04/12/2006 17:30:00 14.6 1.5 18.7 9.9 14.6 1.6 18.3 9.5 11.4 1.5 16.4 8 298 8 291 165 2.8 0 3 2.8 04/12/2006 17:40:00 15.2 1.5 19.1 11.8 15.2 1.6 19.5 11.8 11.8 1.6 16.4 8 301 6 296 165 2.6 0 2.8 2.6 04/12/2006 17:50:00 16.2 1.7 19.9 11.5 16.2 1.7 20.2 11.1 12.2 1.5 17.9 9.1 298 6 293 165 2.5 0 2.6 2.3 04/12/2006 18:00:00 16.4 1.3 20.2 12.2 16.4 1.4 20.2 11.8 13 1.8 19.5 8.8 297 7 291 165 2.4 0 2.6 2.3 04/12/2006 18:10:00 18.7 2 22.6 13.3 18.7 2.1 22.6 13.3 14.3 1.6 19.5 10.3 298 5 302 165 2.3 0 2.6 2.3 04/12/2006 18:20:00 18.3 1.6 22.1 14.9 18.2 1.6 22.1 14.5 14.1 1.7 19.1 9.9 298 6 297 165 2.3 0 2.6 2.3 04/12/2006 18:30:00 19.6 2.3 23.7 14.1 19.6 2.3 24 13.7 15.4 1.9 20.6 10.7 297 6 290 165 2.3 0 2.6 2.1 04/12/2006 18:40:00 20 1.7 23.7 15.3 20 1.8 23.7 15.3 15.5 2.2 21.4 10.7 296 6 297 165 2.3 0 2.6 2.1 04/12/2006 18:50:00 20.3 1.6 24.4 15.6 20.3 1.7 24.4 15.6 15.8 1.8 21.8 11.5 296 6 300 165 2.3 0 2.3 2.1 04/12/2006 19:00:00 19.6 1.5 23.3 15.3 19.6 1.5 22.6 15.3 14.8 1.5 19.1 10.7 299 5 297 165 2.1 0 2.6 1.8 04/12/2006 19:10:00 19 1.7 24.4 14.9 19 1.7 24.8 14.5 15.2 2.2 22.9 10.3 301 7 307 165 2.1 0 2.3 1.8 04/12/2006 19:20:00 19.5 2.3 24.8 14.5 19.5 2.3 24.8 14.5 15.3 2.2 21.4 10.3 298 7 303 165 1.9 0 2.1 1.8 04/12/2006 19:30:00 19.1 2.2 24.8 14.1 19 2.2 24.8 14.5 15.9 2.3 23.3 10.7 303 7 300 165 1.8 0 1.8 1.8 04/12/2006 19:40:00 20.5 1.9 26.3 15.6 20.4 1.9 26.3 16.1 16.7 1.9 23.3 11.8 302 7 305 165 1.7 0 1.8 1.6 04/12/2006 19:50:00 21.3 1.8 25.2 16.4 21.3 1.8 25.2 16.4 16.6 1.9 22.9 11.5 299 6 294 165 1.7 0 1.8 1.4 04/12/2006 20:00:00 20.7 1.7 26 15.3 20.7 1.8 25.6 15.6 16.7 2 24 12.6 302 7 304 165 1.7 0 1.8 1.6 04/12/2006 20:10:00 19.3 2 24 14.5 19.3 2 24.4 14.1 15.7 2.4 22.9 10.7 302 6 302 165 1.5 0 1.8 1.4 04/12/2006 20:20:00 18.6 1.9 24 13.7 18.6 1.9 24.4 13.7 14.8 2.4 21.4 9.9 303 6 307 165 1.5 0 1.6 1.4 04/12/2006 20:30:00 17.9 2 22.1 12.6 17.9 2.1 22.6 12.6 14.4 2 20.6 9.1 299 7 299 165 1.4 0 1.6 1.4 04/12/2006 20:40:00 16.9 2 22.6 12.6 16.9 2 22.9 12.6 13.5 2.3 19.9 8.8 300 7 296 165 1.2 0 1.4 1.1 04/12/2006 20:50:00 17.6 2 22.1 11.8 17.5 2.1 21.8 11.5 15 2.5 21.8 9.5 306 8 313 165 1.1 0 1.4 0.9 04/12/2006 21:00:00 16.8 1.7 20.6 11.1 16.7 1.7 21 11.1 13.6 2.2 20.2 8.8 303 7 300 165 1 0 1.1 0.9 04/12/2006 21:10:00 16.6 2.2 22.1 12.2 16.6 2.2 22.6 11.8 14 2.5 20.2 8.8 306 7 296 165 0.8 0 0.9 0.7 04/12/2006 21:20:00 16.1 1.4 20.2 12.2 15.9 1.4 19.5 12.2 13.5 2 18.3 8 306 8 300 165 0.8 0 0.9 0.7 04/12/2006 21:30:00 16.2 1.7 21 11.8 16.2 1.7 21 12.2 13.3 1.9 19.5 9.1 305 7 294 165 0.7 0 0.9 0.7 04/12/2006 21:40:00 16.8 2 22.1 11.1 16.7 2 21.8 11.5 14.2 2.1 22.9 9.1 307 6 315 165 0.6 0 0.9 0.4 04/12/2006 21:50:00 16.8 1.6 20.6 12.6 16.8 1.6 21 12.6 12.8 1.8 17.9 9.1 298 6 291 165 0.5 0 0.7 0.2 04/12/2006 22:00:00 17.4 1.4 20.2 11.8 17.4 1.4 20.6 11.8 13.3 1.8 18.3 9.9 296 5 284 165 0.6 0 0.7 0.2 04/12/2006 22:10:00 17 1.6 21.4 13 17.1 1.6 21.4 13 13.3 1.7 18.7 8.8 296 5 300 165 0.6 0 0.7 0.4 04/12/2006 22:20:00 16 1.7 19.9 12.2 16 1.7 19.9 11.5 13 2 17.9 8.8 298 8 298 165 0.4 0.1 0.7 0.2 04/12/2006 22:30:00 15.3 1.7 19.5 11.5 15.3 1.7 19.9 11.5 12.5 2.1 19.1 8.4 302 8 310 165 0.2 0 0.4 0.2 04/12/2006 22:40:00 16.5 1.5 22.1 11.8 16.4 1.5 21.4 12.2 14.3 1.8 19.5 9.5 308 6 309 165 0.2 0 0.2 -0.1 04/12/2006 22:50:00 17.3 1.8 21.8 12.6 17.2 1.8 21.4 12.2 14.8 2.3 20.2 9.9 308 6 298 165 0.1 0 0.2 -0.1 04/12/2006 23:00:00 17.7 1.5 22.6 13.7 17.7 1.5 22.1 13.3 15 2.3 20.6 9.1 307 6 298 165 0 0 0.2 -0.3 04/12/2006 23:10:00 18.4 1.5 22.6 14.1 18.4 1.5 22.9 13.7 15.3 2.1 22.9 11.1 306 6 298 165 -0.2 0 -0.1 -0.3 04/12/2006 23:20:00 19.2 1.9 25.2 14.1 19.1 1.9 24.8 14.1 17.1 2.7 25.2 11.1 308 6 308 165 -0.3 0 -0.3 -0.5 04/12/2006 23:30:00 20.5 2.4 26.3 15.3 20.5 2.5 26.3 14.9 17.7 2.9 24.4 11.8 306 6 304 165 -0.6 0 -0.5 -0.8 04/12/2006 23:40:00 20.3 2 24.8 15.6 20.3 2 25.2 15.3 16.5 2 22.9 10.7 303 6 303 165 -0.8 0 -0.5 -0.8 04/12/2006 23:50:00 21.6 2.1 26.3 15.3 21.6 2.2 26.8 15.6 16.7 2.2 23.3 10.3 300 5 296 165 -0.9 0 -0.8 -1.2 04/13/2006 00:00:00 19.8 1.9 23.3 15.3 19.8 2 23.7 14.9 16.3 2.5 22.6 11.5 301 7 297 165 -1 0 -0.8 -1.2 04/13/2006 00:10:00 18.6 2.4 26.3 14.5 18.6 2.4 26.3 14.5 16.3 2.6 24.4 11.5 306 7 305 165 -1.2 0 -1 -1.4 04/13/2006 00:20:00 19.6 1.7 23.3 14.9 19.6 1.7 23.3 14.9 15.2 1.8 19.9 11.1 300 6 295 165 -1.3 0 -1.2 -1.4 04/13/2006 00:30:00 20.2 2 24.8 14.1 20.2 2 24.8 14.1 16.5 2.1 21.8 11.1 301 7 303 165 -1.4 0 -1.2 -1.7 04/13/2006 00:40:00 18.9 1.8 24.8 14.5 18.9 1.8 24.8 14.5 15.2 1.8 21.8 10.3 301 6 297 165 -1.6 0 -1.4 -1.9 04/13/2006 00:50:00 18.4 1.9 23.7 14.5 18.3 2 23.3 14.5 15.4 2.2 23.3 10.3 303 7 311 165 -1.8 0 -1.7 -1.9 04/13/2006 01:00:00 18.5 2.3 24 13.3 18.5 2.3 24 13.3 15.9 2.4 23.3 10.3 306 7 302 165 -2 0 -1.9 -2.1 04/13/2006 01:10:00 18.3 1.3 22.6 14.9 18.3 1.4 22.1 14.9 16.1 2.2 22.1 10.7 307 6 314 165 -2 0 -1.9 -2.1 04/13/2006 01:20:00 19.5 2.1 24 14.5 19.6 2.1 24 14.5 15.4 2.1 22.6 10.7 300 7 295 165 -2 0 -1.9 -2.1 04/13/2006 01:30:00 18.5 1.9 23.7 13 18.5 1.9 23.7 13 15.7 2.5 22.6 10.7 303 8 297 165 -2.1 0 -1.9 -2.4 04/13/2006 01:40:00 19.7 1.7 24 13.7 19.6 1.8 24 13.7 16.6 2.2 22.6 10.7 305 6 299 165 -2.2 0 -2.1 -2.4 04/13/2006 01:50:00 20.5 1.6 24.4 16.4 20.4 1.6 24.4 15.3 18.5 2.2 24 13 308 6 309 165 -2.3 0 -2.1 -2.6 04/13/2006 02:00:00 20.7 2.1 26.3 16.4 20.6 2.2 26.8 15.6 18.3 2.6 24.4 12.2 308 6 305 165 -2.5 0 -2.1 -2.6 04/13/2006 02:10:00 22.1 2.2 26.3 13.7 22.1 2.3 26.8 13.3 20.3 2.5 24.8 13.7 309 6 303 165 -2.5 0 -2.4 -2.6 04/13/2006 02:20:00 23.3 1.7 26.3 19.1 23.2 1.7 26.8 19.1 21.6 2.1 26 16.4 310 5 305 165 -2.5 0 -2.6 -2.6 04/13/2006 02:30:00 22.2 1.5 26 17.6 22.2 1.5 25.6 17.6 19.3 2.3 24.8 13 306 5 308 165 -2.6 0 -2.6 -2.8 04/13/2006 02:40:00 21.6 1.8 25.2 16.8 21.5 1.8 25.6 17.2 18.9 2.4 24 13 306 5 305 165 -2.6 0 -2.6 -2.8 04/13/2006 02:50:00 23.6 1.7 27.1 18.7 23.5 1.8 27.1 18.7 21.3 2 26.3 15.3 307 5 302 165 -2.6 0 -2.6 -2.8 04/13/2006 03:00:00 23.5 1.8 27.5 19.1 23.5 1.9 27.5 18.7 21.5 2.3 27.1 14.5 308 6 307 165 -2.7 0 -2.6 -2.8 04/13/2006 03:10:00 23.8 1.7 27.5 19.1 23.8 1.7 27.5 19.1 22.3 2 26.8 16.1 309 5 309 165 -2.8 0 -2.6 -2.8 04/13/2006 03:20:00 24.8 1.5 27.9 21 24.8 1.5 27.9 19.9 22.6 1.8 26.8 17.6 308 5 304 165 -2.8 0 -2.6 -3 04/13/2006 03:30:00 23.9 1.8 29.1 18.3 23.9 1.8 28.7 18.3 21.4 2.3 28.7 14.1 307 5 310 165 -2.9 0 -2.8 -3 04/13/2006 03:40:00 24.5 2.1 28.7 19.1 24.5 2.1 28.7 18.7 21.5 2.9 29.1 13.3 306 5 302 165 -2.8 0 -2.6 -3 04/13/2006 03:50:00 25.8 1.6 30.2 21.4 25.8 1.7 30.6 21.4 22.7 2.2 28.7 16.4 306 4 302 165 -2.8 0 -2.8 -3 04/13/2006 04:00:00 25.7 1.7 29.4 20.2 25.7 1.8 29.1 20.2 22.7 2.2 29.1 15.6 306 4 302 165 -2.9 0 -2.6 -3 04/13/2006 04:10:00 23.9 1.7 27.9 19.1 23.9 1.7 28.3 19.1 21.7 2.3 27.1 16.4 308 6 311 165 -3 0 -2.8 -3 04/13/2006 04:20:00 24.3 2.4 30.2 18.7 24.3 2.4 30.2 18.7 21.9 2.3 27.9 15.3 308 6 292 165 -2.9 0 -2.8 -3 04/13/2006 04:30:00 25.1 1.9 28.7 18.7 25.1 1.9 28.7 18.3 22.5 2.7 27.9 14.9 307 5 310 165 -2.9 0 -2.8 -3 04/13/2006 04:40:00 25.2 1.5 28.7 21.4 25.2 1.5 28.7 21.4 23.5 2 27.9 16.8 309 5 301 165 -2.9 0 -2.8 -3 04/13/2006 04:50:00 22.4 1.3 25.2 17.2 22.4 1.3 25.6 16.8 21.1 2.1 25.6 15.3 311 5 308 165 -2.9 0 -2.6 -3 04/13/2006 05:00:00 21.8 1.7 27.1 17.6 21.8 1.7 27.1 17.2 20.4 1.8 24.8 15.3 311 6 309 165 -2.8 0 -2.6 -2.8 04/13/2006 05:10:00 22.4 1.6 25.6 16.4 22.3 1.7 26.3 16.4 21.6 1.7 25.2 16.8 312 5 309 165 -2.8 0 -2.6 -2.8 04/13/2006 05:20:00 23.3 1.9 27.9 18.7 23.2 1.9 28.3 18.7 22.3 2.1 27.1 16.8 312 5 307 165 -2.7 0 -2.6 -2.8 04/13/2006 05:30:00 23.6 1.5 27.1 19.5 23.5 1.5 27.1 19.5 23.3 1.7 27.1 18.7 315 6 306 165 -2.5 0 -2.6 -2.8 04/13/2006 05:40:00 22.8 1.5 26.8 18.7 22.7 1.5 26.3 19.1 22.3 1.7 26.3 17.2 315 6 310 165 -2.6 0 -2.6 -2.8 04/13/2006 05:50:00 24.6 1.8 29.4 19.5 24.5 1.8 29.4 20.2 24.4 2.1 30.6 18.3 315 5 310 165 -2.5 0 -2.4 -2.6 04/13/2006 06:00:00 26.5 1.3 29.4 21.4 26.5 1.4 30.2 21.8 25.5 1.7 29.4 20.2 312 4 319 165 -2.4 0 -2.1 -2.6 04/13/2006 06:10:00 26.5 1.6 30.6 21.4 26.4 1.7 30.6 21.4 26.3 1.7 30.6 21 316 6 321 165 -2.2 0 -2.1 -2.6 04/13/2006 06:20:00 25.6 1.6 29.4 20.2 25.5 1.6 29.1 20.2 25.7 1.8 30.2 19.9 317 6 311 165 -2.1 0 -2.1 -2.4 04/13/2006 06:30:00 25.9 1.8 30.2 19.5 25.8 1.8 29.4 19.5 25.8 2 29.8 18.7 316 5 310 165 -2.1 0 -1.9 -2.4 04/13/2006 06:40:00 26.6 2.1 31.3 19.9 26.5 2.2 30.9 19.9 26.2 2.4 31.8 20.2 314 6 310 165 -2 0 -1.9 -2.1 04/13/2006 06:50:00 27.6 1.7 32.9 22.9 27.6 1.7 32.9 22.6 26.7 1.8 31.8 20.6 311 5 310 165 -1.7 0 -1.4 -2.1 04/13/2006 07:00:00 26.8 1.8 31.3 22.1 26.7 1.8 31.3 21.8 26.1 1.9 30.9 21 313 5 311 165 -1.6 0 -1.4 -1.7 04/13/2006 07:10:00 27.5 1.9 32.4 22.1 27.4 1.9 32.4 22.9 27.2 2.1 33.6 21.8 314 5 313 165 -1.6 0 -1.4 -1.9 04/13/2006 07:20:00 27.2 2.1 32.4 18.7 27.1 2.1 32.4 19.1 26.5 2.4 32.1 17.9 312 5 310 165 -1.4 0 -1.2 -1.4 04/13/2006 07:30:00 26.7 1.7 31.8 22.6 26.5 1.7 31.8 21.8 26.1 2.2 31.8 19.9 313 6 314 165 -1.3 0 -1.2 -1.4 04/13/2006 07:40:00 26.2 2 30.2 20.2 26.1 2.1 30.2 20.6 26 2.1 31.3 19.5 316 5 315 165 -1.2 0 -1 -1.4 04/13/2006 07:50:00 25.1 1.7 28.7 20.2 24.9 1.7 28.7 19.9 24.4 2.1 29.8 18.3 317 7 318 165 -1 0 -0.8 -1.2 04/13/2006 08:00:00 25.5 1.7 30.9 20.2 25.2 1.7 29.8 20.2 25 2.1 30.2 18.7 319 7 322 165 -0.9 0 -0.8 -1.2 04/13/2006 08:10:00 26.4 2.4 30.6 20.6 26.2 2.5 30.9 20.2 25.8 2.8 31.3 17.9 316 6 316 165 -0.6 0 -0.5 -0.8 04/13/2006 08:20:00 25.8 2.2 30.6 14.9 25.6 2.2 30.6 14.9 25.3 2.5 31.3 17.6 316 6 307 165 -0.4 0.1 -0.1 -0.5 04/13/2006 08:30:00 26.1 1.5 29.8 21.4 25.9 1.5 29.4 21 25.9 1.7 30.6 20.6 316 5 321 165 -0.3 0 -0.3 -0.5 04/13/2006 08:40:00 25.8 2.3 29.8 19.9 25.7 2.3 29.8 19.9 24.8 2.5 29.8 17.9 312 6 307 165 -0.3 0 -0.1 -0.5 04/13/2006 08:50:00 26.5 2.3 32.1 20.2 26.4 2.4 31.8 20.6 25.1 2.7 32.1 18.7 311 6 321 165 -0.2 0 -0.1 -0.5 04/13/2006 09:00:00 26.5 2.2 32.1 20.6 26.5 2.3 32.1 21 25.7 2.4 31.8 19.1 311 6 301 165 0 0 0.2 -0.1 04/13/2006 09:10:00 24.9 1.8 29.1 20.2 24.7 1.8 29.1 20.2 24.7 2.2 29.8 16.8 318 5 316 165 0.1 0 0.2 -0.1 04/13/2006 09:20:00 26.2 2.1 31.3 20.2 26.1 2.1 30.9 19.9 26 2.3 31.8 19.5 316 5 317 165 0.2 0 0.2 -0.1 04/13/2006 09:30:00 26.8 2 30.9 19.1 26.8 2 30.6 18.7 26.5 2 31.8 20.6 314 4 310 165 0.2 0 0.4 0.2 04/13/2006 09:40:00 26.1 2.4 34.8 19.5 26 2.4 34.4 19.1 25.8 2.5 31.8 18.3 315 5 308 165 0.3 0 0.7 0.2 04/13/2006 09:50:00 23.7 1.9 28.3 18.7 23.5 1.9 27.9 18.7 23.3 2.2 28.3 17.6 318 8 316 165 0.6 0.1 0.9 0.2 04/13/2006 10:00:00 22.7 2.5 28.3 15.3 22.4 2.6 27.9 14.9 22 2.6 28.7 14.5 319 9 312 165 0.7 0 0.9 0.7 04/13/2006 10:10:00 24.9 1.7 29.4 20.6 24.8 1.7 29.1 20.6 24.4 2.1 29.4 18.3 315 5 312 165 0.6 0 0.7 0.7 04/13/2006 10:20:00 24.4 2 29.8 18.7 24.3 2 29.8 18.7 23.7 2.4 30.2 16.1 314 5 307 165 0.6 0 0.9 0.4 04/13/2006 10:30:00 25.3 2 29.4 19.9 25.2 2 29.8 20.2 24.8 2.4 29.1 18.7 313 5 314 165 0.7 0 0.9 0.7 04/13/2006 10:40:00 25.5 2 29.8 17.9 25.4 2.1 29.4 18.3 24.3 2.2 29.1 14.9 312 5 316 165 0.8 0 0.9 0.7 04/13/2006 10:50:00 25 2 29.8 18.7 24.8 2.1 29.8 18.3 24.7 2.2 29.4 16.1 317 5 315 165 0.8 0 0.9 0.7 04/13/2006 11:00:00 26.6 2 30.2 16.4 26.5 2 29.8 16.8 26.2 2.2 29.8 17.2 315 6 312 165 0.7 0 0.9 0.7 04/13/2006 11:10:00 26.2 1.7 29.8 19.1 26.1 1.7 29.8 19.1 26.2 1.8 30.9 20.6 316 5 304 165 0.7 0 0.9 0.7 04/13/2006 11:20:00 25.1 2.2 30.2 18.7 24.9 2.2 30.2 18.7 24.6 2.2 30.2 19.1 316 6 306 165 0.8 0 0.9 0.7 04/13/2006 11:30:00 26.2 2 30.2 20.6 26.1 2.1 30.6 20.6 25 2 28.7 17.9 312 7 306 165 0.8 0 0.9 0.7 04/13/2006 11:40:00 26.7 2.2 31.8 19.9 26.6 2.3 31.8 19.1 25.7 2.7 32.1 17.9 313 6 316 165 0.8 0 0.9 0.9 04/13/2006 11:50:00 27.4 2 31.8 17.9 27.4 2.1 31.8 17.2 26.6 2.1 31.8 20.2 313 6 314 165 0.8 0 0.9 0.7 04/13/2006 12:00:00 27.6 2 31.8 18.7 27.5 2 31.8 19.1 26.1 2.2 31.3 18.3 311 6 307 165 0.8 0 0.9 0.7 04/13/2006 12:10:00 27.3 2 31.8 22.6 27.2 2.1 31.8 22.6 25.7 2.5 31.8 19.1 310 5 307 165 0.9 0 1.1 0.7 04/13/2006 12:20:00 26.9 1.5 30.9 22.1 26.8 1.6 30.9 22.1 25.6 2 30.6 19.1 312 6 305 165 1.1 0 1.4 0.9 04/13/2006 12:30:00 24.6 2 30.9 17.9 24.4 2.1 30.6 17.2 23.6 2.4 30.2 16.8 316 7 324 165 1.3 0 1.6 1.4 04/13/2006 12:40:00 24.5 2.2 29.1 17.2 24.4 2.2 29.4 16.4 23 2.3 28.3 15.6 311 7 304 165 1.5 0 1.8 1.4 04/13/2006 12:50:00 24.1 1.6 27.9 19.5 23.9 1.6 27.9 19.9 23.2 2 29.1 17.6 313 6 315 165 1.6 0 1.8 1.4 04/13/2006 13:00:00 25.6 1.7 29.4 20.2 25.5 1.7 29.1 20.2 24.9 1.9 29.8 19.1 315 6 310 165 1.6 0 1.8 1.4 04/13/2006 13:10:00 24.4 2.2 29.4 19.5 24.2 2.2 29.1 19.1 22.9 2.8 29.8 15.6 313 8 313 165 1.7 0 1.8 1.6 04/13/2006 13:20:00 23.7 1.7 27.1 19.1 23.6 1.8 27.5 18.7 22.3 1.8 26.3 16.1 309 6 304 165 1.7 0 1.8 1.6 04/13/2006 13:30:00 25.4 2.2 30.9 18.7 25.3 2.3 30.6 18.3 24 2.6 29.8 17.9 311 6 307 165 1.7 0 1.8 1.6 04/13/2006 13:40:00 27.6 1.8 31.8 22.1 27.6 1.9 31.8 22.1 25.5 2.5 32.1 19.1 307 5 307 165 1.6 0 1.8 1.4 04/13/2006 13:50:00 25.8 1.7 29.8 21.8 25.7 1.8 29.4 21.4 24.3 2.1 29.8 19.5 309 5 307 165 1.7 0 1.8 1.6 04/13/2006 14:00:00 25.4 1.7 29.4 19.5 25.3 1.8 29.8 19.1 23.6 2.4 28.7 16.4 310 6 302 165 1.7 0 1.8 1.6 04/13/2006 14:10:00 22.7 2.3 27.9 16.8 22.6 2.3 27.9 16.8 21.4 2.6 28.3 15.3 313 8 307 165 1.8 0 1.8 1.6 04/13/2006 14:20:00 23.8 2.3 29.4 17.2 23.7 2.3 29.4 17.6 22.4 2.6 28.7 16.1 311 8 311 165 1.8 0 2.1 1.8 04/13/2006 14:30:00 24.2 2.1 29.1 19.1 24.1 2.2 29.1 18.7 22.9 2.5 27.9 16.8 312 6 309 165 1.9 0 2.1 1.6 04/13/2006 14:40:00 22.9 2.3 27.5 15.6 22.8 2.3 27.9 15.6 21.6 2.6 27.9 15.6 311 7 315 165 2.3 0 2.6 1.8 04/13/2006 14:50:00 23.8 1.7 28.3 19.1 23.7 1.8 27.9 19.1 22.1 2.1 27.1 16.8 310 6 310 165 2.2 0 2.3 2.1 04/13/2006 15:00:00 25.3 1.8 29.1 20.2 25.2 1.8 29.1 19.9 23.2 2.3 28.7 16.4 309 5 306 165 2.1 0.1 2.3 1.8 04/13/2006 15:10:00 25.8 2.2 29.8 18.3 25.7 2.2 29.8 17.6 24.2 1.9 28.7 18.3 310 5 305 165 1.9 0 2.3 1.8 04/13/2006 15:20:00 25.1 2.4 30.2 19.9 25 2.4 30.2 19.5 23.8 2.3 29.8 17.9 312 6 305 165 2.1 0.1 2.6 1.8 04/13/2006 15:30:00 25 2.1 31.3 19.9 24.8 2.1 31.3 19.5 24 2 30.6 17.9 313 6 319 165 2 0.1 2.3 1.8 04/13/2006 15:40:00 25.2 1.9 29.4 18.7 25 1.9 29.1 19.5 24.9 2.3 30.6 17.9 317 6 319 165 1.9 0 2.1 1.8 04/13/2006 15:50:00 25.1 2.1 32.1 20.2 24.9 2.1 31.8 20.2 24.4 2.6 31.8 17.6 316 6 309 165 1.9 0 2.1 1.8 04/13/2006 16:00:00 25.2 1.7 29.4 20.6 24.9 1.8 29.4 20.2 24 2.2 29.1 17.9 313 6 316 165 1.7 0 1.8 1.4 04/13/2006 16:10:00 25.4 2.3 31.3 20.2 25.3 2.4 31.8 19.1 24 2.5 31.8 17.2 311 5 309 165 1.4 0.1 1.6 1.1 04/13/2006 16:20:00 26.3 1.9 30.6 21 26.2 1.9 30.6 20.2 25.2 2.2 29.8 19.9 312 7 309 165 1.2 0 1.6 0.9 04/13/2006 16:30:00 25.1 2.4 30.9 18.3 24.9 2.5 30.9 16.8 24.2 2.4 32.9 16.4 316 7 312 165 1.4 0.2 1.8 0.9 04/13/2006 16:40:00 25.3 2.4 30.9 18.3 25.1 2.4 30.9 18.3 24.4 2.8 30.2 16.8 315 6 310 165 1.4 0.2 1.8 1.1 04/13/2006 16:50:00 26.6 1.7 29.8 19.9 26.4 1.7 29.8 19.5 25.7 2 29.8 20.2 314 5 313 165 1.5 0 1.6 1.4 04/13/2006 17:00:00 24.2 2.4 29.4 17.6 24 2.4 29.8 17.9 23.4 2.6 28.3 16.4 315 6 310 165 1.4 0 1.6 1.4 04/13/2006 17:10:00 25.9 2.1 32.1 19.9 25.8 2.2 32.1 19.9 25.2 2.5 32.1 17.9 314 5 310 165 1.4 0 1.6 1.4 04/13/2006 17:20:00 24.8 1.7 29.8 17.9 24.6 1.8 29.4 17.9 24 2.4 29.4 14.9 314 6 317 165 1.4 0 1.6 1.4 04/13/2006 17:30:00 22.6 2.1 26.3 16.1 22.3 2 26.3 14.9 21.1 2.6 26.3 13.3 314 7 319 165 1.2 0 1.4 1.1 04/13/2006 17:40:00 22.3 2.1 27.5 16.1 22.1 2.1 27.9 16.1 21.3 2.4 27.1 14.1 315 6 315 165 1.1 0 1.4 0.9 04/13/2006 17:50:00 23.3 2.1 27.1 16.4 23.1 2.1 27.1 16.4 22.2 2.2 26.8 14.5 314 6 315 165 1 0 1.4 0.9 04/13/2006 18:00:00 22.9 2.2 27.5 16.8 22.8 2.2 27.9 17.2 21.7 2.6 27.9 15.3 313 7 320 165 0.8 0 1.1 0.7 04/13/2006 18:10:00 23.6 2 29.1 16.4 23.5 2 28.7 16.8 22.3 2.5 27.1 14.9 313 6 313 165 0.8 0 0.9 0.7 04/13/2006 18:20:00 22.6 1.7 26.3 16.8 22.3 1.7 26.8 16.8 21.5 2 26 13.7 316 6 312 165 0.7 0 0.9 0.7 04/13/2006 18:30:00 21.1 2.3 27.1 16.1 20.9 2.2 27.1 15.6 20.4 2.5 27.1 13.3 318 6 314 165 0.8 0 0.9 0.7 04/13/2006 18:40:00 21.7 2.1 26.3 15.6 21.5 2.1 26.8 15.3 20.8 2.3 26 14.5 317 7 315 165 0.8 0 0.9 0.7 04/13/2006 18:50:00 21.7 2 27.1 15.6 21.5 2.1 27.1 15.6 20.9 2.3 26.8 13.3 316 6 302 165 0.6 0 0.9 0.4 04/13/2006 19:00:00 22.7 2.2 28.3 15.6 22.6 2.3 27.9 15.6 21.9 2.3 26.3 14.9 315 6 307 165 0.3 0.1 0.7 0.2 04/13/2006 19:10:00 21.8 2.1 26 15.3 21.5 2.1 26 14.9 21.3 2.3 26.3 15.3 317 6 309 165 0.2 0 0.2 0.2 04/13/2006 19:20:00 20.4 1.8 26.8 16.1 20.2 1.8 26.3 16.1 19.3 2.1 24.8 13.3 316 7 307 165 0.1 0 0.2 -0.1 04/13/2006 19:30:00 22.2 2.3 27.5 15.6 22 2.3 27.5 15.3 21.3 2.6 27.1 14.1 315 6 313 165 0.1 0 0.2 -0.1 04/13/2006 19:40:00 23 1.7 27.1 17.2 22.8 1.7 27.1 17.2 22.5 1.8 26.8 16.4 315 6 311 165 0 0 0.2 -0.1 04/13/2006 19:50:00 22.5 1.7 26.3 17.2 22.4 1.8 26 16.4 21.8 2 26 16.8 316 6 313 165 -0.1 0 0.2 -0.3 04/13/2006 20:00:00 22.7 2 27.1 16.8 22.5 2 27.5 16.8 21.6 2.4 27.5 15.3 314 7 317 165 -0.2 0 -0.1 -0.3 04/13/2006 20:10:00 22.9 1.9 27.1 16.8 22.8 1.9 27.5 16.8 22 2.3 27.9 16.1 315 6 323 165 -0.3 0 -0.1 -0.5 04/13/2006 20:20:00 22 2 26.8 16.4 21.8 2 26.3 16.1 21.2 2 25.6 15.3 315 6 304 165 -0.5 0 -0.3 -0.8 04/13/2006 20:30:00 23.1 1.7 26.3 17.9 23.1 1.7 26.3 17.6 21.5 2.5 26.8 15.3 311 6 308 165 -0.6 0 -0.5 -0.8 04/13/2006 20:40:00 22.8 1.7 28.3 19.1 22.7 1.7 28.3 18.7 21.5 2.2 26.8 15.3 311 6 304 165 -0.7 0 -0.5 -0.8 04/13/2006 20:50:00 24 1.9 28.7 18.3 23.9 1.9 28.7 18.7 22.7 2.1 27.9 17.2 312 5 302 165 -0.6 0 -0.5 -0.8 04/13/2006 21:00:00 24.1 2.1 29.8 17.6 24.1 2.1 29.4 17.2 23 2.5 29.4 15.6 312 7 309 165 -0.7 0.1 -0.5 -0.8 04/13/2006 21:10:00 24.7 1.7 29.4 20.2 24.7 1.8 29.8 20.2 23.7 2 29.1 17.9 313 6 297 165 -0.9 0 -0.8 -1 04/13/2006 21:20:00 25.9 1.5 30.6 21.4 25.8 1.5 30.9 21.4 24.9 1.9 31.8 19.1 314 6 310 165 -0.9 0 -0.8 -1.2 04/13/2006 21:30:00 25.1 1.8 29.4 20.2 25 1.8 29.1 20.2 24.5 1.9 29.1 18.3 315 6 319 165 -1 0 -0.8 -1.2 04/13/2006 21:40:00 24.1 2.1 28.7 14.9 23.9 2.1 28.3 14.9 23.2 2.5 28.3 14.5 315 6 322 165 -1 0 -0.8 -1.2 04/13/2006 21:50:00 23.1 2 27.9 18.3 22.9 2.1 28.3 17.9 22.1 2.4 27.9 15.6 314 7 313 165 -1.1 0 -0.8 -1.2 04/13/2006 22:00:00 22.2 1.7 28.3 18.3 22.1 1.8 28.7 17.6 21.4 2 26.8 14.1 312 6 297 165 -1.3 0 -1.2 -1.4 04/13/2006 22:10:00 22 1.9 27.1 17.6 21.9 1.9 27.1 17.6 21.1 2.3 27.9 15.6 313 6 305 165 -1.3 0 -1.2 -1.4 04/13/2006 22:20:00 22.3 2.2 27.1 16.4 22.2 2.2 26.8 16.1 20.7 2.5 27.1 13.7 312 6 308 165 -1.3 0 -1.2 -1.4 04/13/2006 22:30:00 22.4 2.1 27.9 16.8 22.3 2.1 27.5 16.4 20.4 2.4 26 14.9 309 6 307 165 -1.3 0 -1.2 -1.4 04/13/2006 22:40:00 20.2 1.7 24.4 15.3 20.1 1.7 24.8 14.9 19.2 1.9 24.8 14.1 314 8 316 165 -1.3 0 -1.2 -1.4 04/13/2006 22:50:00 21.6 2.4 26.8 16.1 21.5 2.4 27.1 15.6 20.7 2.7 27.1 13.7 314 6 308 165 -1.4 0 -1.2 -1.4 04/13/2006 23:00:00 21.8 1.6 25.6 17.9 21.7 1.7 25.6 17.6 21.1 1.9 25.2 16.1 313 5 313 165 -1.4 0 -1.2 -1.4 04/13/2006 23:10:00 19.8 1.9 26 15.6 19.6 1.9 26 15.3 18.7 2.4 26.3 13.3 313 7 310 165 -1.4 0 -1.2 -1.4 04/13/2006 23:20:00 21.6 1.8 25.6 15.6 21.6 1.9 26 16.1 19.5 2.1 25.2 14.1 309 5 303 165 -1.4 0 -1.4 -1.4 04/13/2006 23:30:00 21.3 1.7 26 16.1 21.1 1.7 26 16.4 19.2 2.1 24.4 13.3 310 6 297 165 -1.5 0 -1.4 -1.4 04/13/2006 23:40:00 19.5 2 24.4 13.7 19.3 2 24.4 13.3 18.3 2.2 25.6 12.6 315 6 315 165 -1.4 0 -1.4 -1.7 04/13/2006 23:50:00 20.3 1.9 25.6 15.3 20.1 1.9 25.2 14.9 18.7 2 23.3 12.2 312 5 306 165 -1.4 0 -1.2 -1.4 04/14/2006 00:00:00 20.4 1.7 24.4 14.9 20.3 1.7 24.8 15.6 18.5 2.2 24.4 13 312 5 302 165 -1.4 0 -1.2 -1.4 04/14/2006 00:10:00 19.7 2 23.7 13 19.5 2 23.7 12.6 18.2 1.9 22.6 12.6 313 7 312 165 -1.3 0 -1.2 -1.4 04/14/2006 00:20:00 20.2 1.6 24.4 15.3 20.1 1.6 24 15.3 18 1.8 22.9 12.2 310 6 309 165 -1.3 0 -1.2 -1.4 04/14/2006 00:30:00 19.7 2.1 24.8 14.5 19.5 2.1 24.8 14.9 17.9 2.3 24.4 12.6 312 6 312 165 -1.4 0 -1.2 -1.4 04/14/2006 00:40:00 21.5 1.5 25.2 16.1 21.3 1.5 25.2 16.4 19.9 1.7 24 14.5 311 5 308 165 -1.4 0 -1.2 -1.7 04/14/2006 00:50:00 20.9 2 26 16.1 20.7 2.1 26 16.1 18.6 2.1 24.8 13 310 6 305 165 -1.4 0 -1.4 -1.7 04/14/2006 01:00:00 20 1.9 24.8 13.7 19.7 1.8 24.4 14.5 18.3 2.1 23.3 11.8 314 8 316 165 -1.5 0 -1.4 -1.7 04/14/2006 01:10:00 20.9 1.7 25.2 15.6 20.7 1.7 25.2 16.1 20 2 24 13.7 317 6 322 165 -1.5 0 -1.4 -1.7 04/14/2006 01:20:00 19.3 1.5 23.7 14.9 19.1 1.4 23.3 15.3 18.2 1.7 22.1 13 316 6 314 165 -1.7 0 -1.4 -1.9 04/14/2006 01:30:00 20.3 1.7 23.7 14.9 20.2 1.7 23.7 14.9 18.2 2.2 23.7 12.6 311 5 312 165 -1.6 0 -1.4 -1.9 04/14/2006 01:40:00 21.7 1.5 24.8 16.4 21.6 1.5 25.2 16.1 18.8 2.3 24.4 12.2 307 5 302 165 -1.6 0 -1.4 -1.7 04/14/2006 01:50:00 22.3 2.1 26.8 17.6 22.2 2.1 26.8 17.2 18.8 2.7 24.4 12.2 306 6 302 165 -1.6 0 -1.4 -1.7 04/14/2006 02:00:00 22.2 1.7 26 17.2 22.1 1.7 25.6 16.8 19.6 2.3 25.2 13.3 307 6 292 165 -1.4 0 -1.4 -1.4 04/14/2006 02:10:00 23 1.4 27.5 19.5 22.9 1.5 27.5 19.1 20.4 1.9 25.6 16.1 308 5 306 165 -1.5 0 -1.4 -1.7 04/14/2006 02:20:00 22.5 1.8 27.1 16.8 22.3 1.9 27.1 16.8 20.5 2.1 25.6 15.3 311 7 296 165 -1.6 0 -1.4 -1.9 04/14/2006 02:30:00 21.9 1.7 26.3 17.2 21.7 1.7 26 17.2 21 2 26 16.1 315 7 325 165 -1.6 0 -1.4 -1.9 04/14/2006 02:40:00 20.8 1.6 25.2 15.6 20.7 1.6 25.2 15.6 19.5 1.7 23.3 14.5 312 5 307 165 -1.7 0 -1.4 -1.9 04/14/2006 02:50:00 20.6 1.6 24 16.1 20.5 1.7 24.8 16.4 19.3 2 23.7 12.6 313 7 303 165 -1.6 0 -1.4 -1.9 04/14/2006 03:00:00 21 2 26 16.4 21 2 26 16.1 19.3 2 25.6 13.7 311 6 309 165 -1.6 0 -1.4 -1.7 04/14/2006 03:10:00 20.9 1.7 24.8 16.1 20.8 1.8 24.8 15.6 18.9 2 24.4 13.3 310 6 310 165 -1.5 0 -1.4 -1.7 04/14/2006 03:20:00 21.3 2 26.3 16.4 21.2 2 26 16.4 19.7 2.2 24.8 14.1 311 5 301 165 -1.7 0 -1.4 -1.9 04/14/2006 03:30:00 22.7 1.6 27.5 18.7 22.6 1.7 27.1 18.3 21 2.2 26.8 14.5 310 5 315 165 -1.6 0 -1.4 -1.7 04/14/2006 03:40:00 23.8 2.2 29.1 18.3 23.8 2.2 28.7 18.3 22.3 2.3 28.7 16.1 311 6 314 165 -1.5 0 -1.4 -1.7 04/14/2006 03:50:00 25 1.8 30.2 19.5 25 1.9 30.2 19.5 23.3 2.4 29.4 16.1 310 6 309 165 -1.5 0 -1.4 -1.7 04/14/2006 04:00:00 22.6 2.2 27.9 17.2 22.5 2.2 27.5 16.8 20.6 2.6 27.1 14.9 310 6 318 165 -1.6 0 -1.4 -1.7 04/14/2006 04:10:00 22.4 1.3 25.6 18.7 22.3 1.3 25.2 18.7 20.1 1.9 24.8 14.5 308 4 310 165 -1.6 0 -1.4 -1.9 04/14/2006 04:20:00 22.3 1.7 27.1 17.9 22.2 1.7 27.1 18.3 20.5 2.2 26 14.9 311 7 310 165 -1.6 0 -1.4 -1.9 04/14/2006 04:30:00 23.7 2 29.8 18.3 23.6 2 30.2 18.3 21.7 2.6 28.7 14.1 310 6 307 165 -1.6 0 -1.4 -1.9 04/14/2006 04:40:00 24.4 2 28.7 18.7 24.3 2.1 29.1 18.7 22.9 2.3 27.5 16.4 311 6 309 165 -1.5 0 -1.4 -1.7 04/14/2006 04:50:00 23.7 2 29.8 16.8 23.6 2.1 30.2 17.2 22.9 2.1 29.4 16.4 316 7 311 165 -1.6 0 -1.4 -1.7 04/14/2006 05:00:00 23.5 1.7 27.5 18.3 23.3 1.7 27.1 18.7 22.9 1.8 27.1 17.2 315 6 309 165 -1.6 0 -1.4 -1.7 04/14/2006 05:10:00 24.4 1.6 28.3 19.1 24.3 1.7 28.3 19.1 22.7 2 27.1 16.8 310 5 315 165 -1.6 0 -1.4 -1.7 04/14/2006 05:20:00 25.2 2.2 30.6 19.9 25.1 2.3 30.6 18.7 23.8 2.9 30.6 15.6 311 6 314 165 -1.6 0 -1.4 -1.9 04/14/2006 05:30:00 24.4 1.9 28.7 20.2 24.3 1.9 28.7 19.9 23.2 2.3 27.5 16.8 311 6 305 165 -1.7 0 -1.4 -1.9 04/14/2006 05:40:00 27.1 2.5 32.4 18.7 27.1 2.5 32.9 19.1 26.5 2.9 33.6 17.9 312 6 317 165 -1.6 0.1 -1.4 -1.9 04/14/2006 05:50:00 26 2.1 31.8 20.6 25.9 2.2 31.8 20.2 24.1 2.4 30.9 17.9 310 6 309 165 -1.6 0 -1.4 -1.9 04/14/2006 06:00:00 25.8 2.1 31.3 20.2 25.8 2.2 31.3 20.6 24.9 2.5 30.9 18.7 313 7 310 165 -1.6 0 -1.4 -1.7 04/14/2006 06:10:00 26.1 2.4 31.8 19.5 26.1 2.5 31.8 18.7 25.5 2.8 32.1 17.6 314 6 313 165 -1.6 0 -1.4 -1.9 04/14/2006 06:20:00 24.8 2.4 32.1 19.5 24.7 2.5 32.1 19.5 24 2.7 32.4 16.4 313 6 313 165 -1.6 0 -1.4 -1.7 04/14/2006 06:30:00 24.6 2.5 31.8 17.9 24.5 2.6 31.8 17.9 24.2 2.8 31.3 17.2 316 7 321 165 -1.6 0 -1.4 -1.9 04/14/2006 06:40:00 26.2 2.6 33.6 18.7 26.1 2.7 33.2 18.3 26.2 2.7 34 19.1 315 7 313 165 -1.4 0.1 -1.2 -1.7 04/14/2006 06:50:00 26.6 2.4 32.1 19.9 26.5 2.5 32.4 19.9 26.3 2.7 31.8 17.9 316 5 311 165 -1.4 0 -1.2 -1.4 04/14/2006 07:00:00 24.4 2.1 29.1 18.7 24.2 2.1 29.1 17.9 24 2.4 29.8 16.4 317 6 313 165 -1.6 0 -1.4 -1.9 04/14/2006 07:10:00 25.1 2.3 30.9 19.1 25 2.3 31.8 18.7 24.6 2.3 29.8 18.7 314 5 316 165 -1.7 0 -1.4 -1.9 04/14/2006 07:20:00 22.6 1.9 27.9 17.9 22.5 1.9 27.1 17.6 21.4 2.4 27.1 14.9 312 6 308 165 -1.8 0 -1.4 -1.9 04/14/2006 07:30:00 21.6 2.3 26 15.3 21.4 2.3 26 14.9 21.1 2.6 27.9 14.9 316 6 316 165 -1.7 0 -1.4 -1.9 04/14/2006 07:40:00 22.7 1.9 27.9 17.2 22.6 1.9 27.9 17.2 22.2 2.2 26.8 13.7 315 5 316 165 -1.6 0 -1.4 -1.7 04/14/2006 07:50:00 23.6 1.7 27.5 17.9 23.4 1.7 27.5 18.3 22.7 2.2 27.5 14.5 314 5 317 165 -1.4 0 -1.2 -1.7 04/14/2006 08:00:00 25 1.7 30.6 19.5 24.9 1.8 30.6 19.5 24.3 2.1 29.4 16.8 314 5 307 165 -1.4 0 -1.2 -1.4 04/14/2006 08:10:00 25.7 1.4 29.4 18.7 25.6 1.5 29.1 18.3 24.8 1.8 29.1 18.7 313 5 316 165 -1.4 0 -1.2 -1.4 04/14/2006 08:20:00 26.4 2.4 30.9 17.9 26.4 2.4 30.9 17.9 25.5 2.7 31.3 17.9 312 5 310 165 -1.3 0 -1 -1.4 04/14/2006 08:30:00 25.5 1.8 30.9 19.5 25.4 1.9 30.9 19.1 24.7 2.1 30.2 17.9 313 5 307 165 -1.2 0 -1 -1.4 04/14/2006 08:40:00 21.9 2.4 27.1 15.3 21.7 2.5 26.8 15.3 21.1 2.6 27.9 14.5 316 6 319 165 -1 0 -0.8 -1.2 04/14/2006 08:50:00 24 1.8 28.3 17.9 23.8 1.8 27.9 17.9 23 2.3 28.7 15.6 315 6 312 165 -1.2 0 -1 -1.4 04/14/2006 09:00:00 24.8 2.2 32.1 19.1 24.6 2.2 32.1 19.5 24.4 2.3 32.4 18.3 318 7 316 165 -1.1 0 -1 -1.2 04/14/2006 09:10:00 25 2.2 32.1 18.7 24.9 2.2 32.1 18.7 23.9 2.5 32.4 17.2 313 6 311 165 -1.2 0 -1 -1.4 04/14/2006 09:20:00 26.4 1.8 30.6 21.8 26.4 2 30.6 21.4 25.2 2.4 31.3 18.7 310 6 313 165 -1.3 0 -1.2 -1.4 04/14/2006 09:30:00 24.3 1.8 28.7 19.5 24.2 1.9 29.1 19.5 21.6 2.1 26.8 16.1 307 6 302 165 -1.4 0 -1.2 -1.7 04/14/2006 09:40:00 24.3 1.5 27.5 18.7 24.2 1.6 27.9 18.7 20.2 2.1 27.1 14.9 305 5 300 165 -1.6 0 -1.4 -1.7 04/14/2006 09:50:00 24 1.2 26.8 19.9 24 1.2 26.3 20.2 20.8 1.6 24 16.4 306 3 302 165 -1.6 0 -1.4 -1.7 04/14/2006 10:00:00 22.6 1.4 25.6 17.9 22.5 1.5 26 17.9 19.4 1.8 23.7 14.1 306 5 313 165 -1.4 0 -1.2 -1.7 04/14/2006 10:10:00 22.2 1.2 24.8 18.3 22.1 1.3 24.8 17.9 20.3 1.6 24 15.3 310 4 312 165 -1.4 0 -1.2 -1.4 04/14/2006 10:20:00 21.3 1.8 25.6 15.6 21.2 1.8 25.2 15.3 20.6 2.1 25.2 14.5 315 7 315 165 -1.1 0 -0.8 -1.4 04/14/2006 10:30:00 19.5 2.1 24.8 14.5 19.3 2 24.4 14.1 18.9 2 25.2 14.1 319 8 324 165 -0.7 0 -0.5 -1 04/14/2006 10:40:00 21.6 2.2 27.1 15.6 21.4 2.2 26.8 16.1 21.1 2.6 27.1 13.3 319 7 332 165 -0.5 0 -0.3 -0.8 04/14/2006 10:50:00 23.2 2.2 28.3 15.3 23 2.3 29.1 15.6 22.9 2.4 29.1 17.2 320 7 321 165 -0.6 0 -0.3 -0.8 04/14/2006 11:00:00 20.7 2.2 26.3 13.7 20.5 2.2 26.3 13.7 20 2.4 26.8 13.7 317 7 315 165 -0.5 0 -0.3 -0.5 04/14/2006 11:10:00 20.3 2.3 26 13.3 20.2 2.3 26 13.3 19.7 2.5 26 13 318 8 318 165 -0.4 0 -0.3 -0.5 04/14/2006 11:20:00 20.6 2.1 26 14.5 20.4 2.1 26.3 14.5 19.8 2.3 26.3 14.5 317 8 311 165 -0.5 0 -0.3 -0.5 04/14/2006 11:30:00 21.3 1.9 26.3 15.6 21.2 1.9 26 15.3 20.1 2.4 26.3 12.2 314 8 303 165 -0.6 0 -0.3 -0.8 04/14/2006 11:40:00 22.9 1.5 26 18.3 22.8 1.5 26 18.7 20.9 2 24.8 14.9 308 5 301 165 -0.8 0.1 -0.5 -0.8 04/14/2006 11:50:00 23 1.8 26.8 14.9 23.1 1.8 26.8 14.9 21.2 2.6 26 14.1 308 5 305 165 -0.6 0 -0.5 -0.8 04/14/2006 12:00:00 23.3 1.6 27.1 18.7 23.3 1.7 26.8 18.7 21.7 2.3 26 15.6 309 4 307 165 -0.6 0 -0.5 -0.8 04/14/2006 12:10:00 24.3 1.1 27.5 21.8 24.4 1.1 27.5 21.4 21.5 2 26 14.9 307 3 305 165 -0.6 0 -0.5 -0.8 04/14/2006 12:20:00 24.4 1.6 28.3 19.5 24.4 1.6 28.7 19.1 21.8 2.3 26.3 14.1 307 4 303 165 -0.7 0 -0.5 -0.8 04/14/2006 12:30:00 23.6 1.3 26.8 20.2 23.6 1.3 26.8 20.2 20.9 2.3 26.8 14.5 307 4 305 165 -0.6 0 -0.5 -0.8 04/14/2006 12:40:00 23.6 1.5 26.3 17.2 23.6 1.5 26.8 17.2 21.1 2.1 26 14.5 307 4 307 165 -0.5 0 -0.3 -0.5 04/14/2006 12:50:00 23.3 1.1 25.6 20.6 23.3 1.1 26 20.2 21.4 1.7 24.8 15.3 308 3 302 165 -0.4 0 -0.3 -0.5 04/14/2006 13:00:00 23.5 1.1 27.1 20.2 23.5 1.2 27.1 20.2 21.2 2 25.2 14.5 308 3 305 165 -0.3 0 -0.3 -0.5 04/14/2006 13:10:00 22.2 1.4 26 18.3 22.1 1.5 25.2 17.6 20.9 1.6 24.8 14.5 311 5 311 165 -0.3 0 -0.1 -0.5 04/14/2006 13:20:00 22.2 1.7 26.3 16.4 22.1 1.7 26 16.8 21.9 1.9 27.1 17.2 316 5 318 165 -0.3 0 -0.1 -0.5 04/14/2006 13:30:00 21 1.7 25.6 16.8 20.9 1.7 26 16.8 20.3 2.3 25.6 13.3 315 6 310 165 -0.1 0 0.2 -0.3 04/14/2006 13:40:00 21 1.7 25.2 14.9 20.9 1.7 25.2 15.6 19.4 2.1 24 12.6 311 5 309 165 -0.1 0 0.2 -0.3 04/14/2006 13:50:00 20.6 1.4 23.7 16.8 20.5 1.5 23.7 16.4 18.9 1.7 22.9 14.9 311 5 307 165 -0.1 0 0.2 -0.3 04/14/2006 14:00:00 21 1.3 24 17.6 20.9 1.3 24.4 16.8 19.1 1.7 23.7 14.1 311 5 310 165 -0.1 0 0.2 -0.3 04/14/2006 14:10:00 20.6 1.4 24 16.1 20.5 1.5 23.7 16.1 18.8 1.7 22.9 14.5 311 5 312 165 -0.1 0 0.2 -0.3 04/14/2006 14:20:00 21.2 1 23.7 18.3 21.1 1 23.7 17.9 18.8 1.9 22.6 12.2 309 4 310 165 0 0 0.2 -0.1 04/14/2006 14:30:00 20.7 1.2 24.8 16.8 20.7 1.2 24.8 16.8 18.3 1.7 21.8 13.7 310 4 304 165 0.1 0 0.2 -0.1 04/14/2006 14:40:00 20.7 1.3 23.3 16.4 20.6 1.3 22.9 15.6 18.8 1.7 22.6 14.9 311 5 310 165 0.2 0 0.4 -0.1 04/14/2006 14:50:00 20.2 1.6 23.7 16.1 20.1 1.7 23.3 15.6 18.9 1.8 23.3 12.2 312 5 310 165 0.2 0 0.2 -0.1 04/14/2006 15:00:00 20.3 1.7 24.4 14.5 20.1 1.7 24 14.1 18.8 1.7 22.6 14.5 312 5 311 165 0.2 0 0.4 -0.1 04/14/2006 15:10:00 20.2 1.6 24 15.3 20 1.6 23.7 15.6 19.2 1.7 23.3 15.3 315 6 312 165 0.2 0 0.4 0.2 04/14/2006 15:20:00 20.5 1.5 24.4 16.4 20.3 1.5 24 16.1 19.8 1.7 24.8 14.9 315 6 319 165 0.1 0 0.2 -0.1 04/14/2006 15:30:00 20.2 1.4 24.8 17.2 20.1 1.5 24 16.4 18.9 1.6 22.6 13.7 313 5 321 165 0.1 0 0.2 -0.1 04/14/2006 15:40:00 20.4 1.6 24.4 16.1 20.3 1.6 24 16.4 19.3 1.8 23.3 13.7 313 6 312 165 -0.1 0 0.2 -0.3 04/14/2006 15:50:00 20 1.5 23.3 15.3 19.8 1.5 22.9 15.6 18.7 1.9 23.3 11.5 315 7 305 165 -0.1 0 0.2 -0.3 04/14/2006 16:00:00 19.2 1.3 21.8 15.3 19.1 1.4 21.8 14.9 18.4 1.7 22.1 13.7 314 5 314 165 -0.1 0 0.2 -0.3 04/14/2006 16:10:00 19.9 1.8 24 14.9 19.7 1.9 23.7 14.9 18.7 1.7 23.3 13.3 313 7 305 165 -0.2 0 -0.1 -0.3 04/14/2006 16:20:00 19 1.4 22.9 14.5 18.9 1.5 22.6 14.5 17.7 2 22.6 11.8 312 7 323 165 -0.2 0 -0.1 -0.5 04/14/2006 16:30:00 19.5 1.5 22.6 15.6 19.4 1.5 22.6 15.3 17.5 1.8 21 11.5 311 5 308 165 -0.3 0 -0.1 -0.5 04/14/2006 16:40:00 20.9 1.5 24 16.4 20.9 1.6 24 16.4 19.1 2 23.3 13 309 4 307 165 -0.5 0 -0.3 -0.8 04/14/2006 16:50:00 21.1 1.5 24 15.6 21 1.5 24 16.1 19.1 1.8 22.9 13.7 310 5 304 165 -0.7 0.1 -0.5 -0.8 04/14/2006 17:00:00 21.4 1.3 23.7 17.6 21.4 1.3 23.7 17.6 19.6 1.7 22.9 14.9 310 4 309 165 -0.9 0 -0.8 -1 04/14/2006 17:10:00 21.9 1.4 24.8 16.8 21.9 1.5 25.2 16.4 20.4 1.7 24 14.9 310 4 309 165 -1 0 -0.8 -1.2 04/14/2006 17:20:00 22.2 1.2 24.8 17.6 22.2 1.3 24.8 17.2 20.9 1.5 24 14.9 310 4 315 165 -1.2 0 -1 -1.4 04/14/2006 17:30:00 21.8 1.3 24 17.6 21.8 1.4 24 17.6 20.3 1.7 23.3 15.3 310 4 317 165 -1.3 0 -1.2 -1.4 04/14/2006 17:40:00 21.4 1.2 23.7 16.8 21.3 1.3 23.7 16.4 19.7 1.6 23.3 15.3 310 4 307 165 -1.3 0 -1.2 -1.4 04/14/2006 17:50:00 22.2 1.2 24.4 18.7 22.2 1.2 24.8 18.3 19.8 1.5 22.6 15.3 308 4 306 165 -1.5 0 -1.2 -1.7 04/14/2006 18:00:00 20.8 1.7 24.8 16.4 20.7 1.7 24.8 16.4 18.4 2.1 23.3 13.7 308 5 305 165 -1.7 0 -1.4 -1.9 04/14/2006 18:10:00 21.8 1.3 25.6 18.3 21.8 1.3 25.2 18.3 19 2.1 24.8 13.3 307 4 297 165 -2 0 -1.9 -2.1 04/14/2006 18:20:00 22.1 1.7 24.8 16.8 22.1 1.8 24.4 16.4 18.8 2.2 23.7 13.3 306 4 312 165 -2 0 -1.9 -2.1 04/14/2006 18:30:00 20 1.7 26 15.3 19.9 1.7 26.3 14.9 18.3 2.3 25.6 11.8 308 6 308 165 -1.9 0 -1.7 -2.1 04/14/2006 18:40:00 20.1 1.5 23.7 16.1 20.1 1.5 23.7 16.1 18.2 2.6 24 11.5 309 6 307 165 -1.9 0 -1.7 -1.9 04/14/2006 18:50:00 19.7 1.6 23.3 15.6 19.6 1.7 22.9 15.6 18.1 2.5 22.9 11.8 309 6 311 165 -1.9 0 -1.7 -1.9 04/14/2006 19:00:00 20.1 1.8 25.2 15.6 20 1.8 25.2 15.6 18.4 2 22.6 12.2 309 6 299 165 -2 0 -1.9 -2.1 04/14/2006 19:10:00 23.1 1.2 25.6 19.5 23.1 1.3 26 19.1 21 1.7 24.4 16.1 308 5 304 165 -2.4 0.1 -2.1 -2.6 04/14/2006 19:20:00 21.8 1.2 25.2 17.2 21.8 1.3 25.2 17.2 18.9 2.1 23.7 13 307 5 305 165 -2.5 0 -2.4 -2.6 04/14/2006 19:30:00 20.6 1.2 24.4 16.4 20.6 1.2 24 16.1 16.9 2 22.6 11.1 306 4 297 165 -2.6 0 -2.6 -2.8 04/14/2006 19:40:00 19 1.4 22.1 14.9 19 1.5 22.1 14.9 15.4 2.1 20.2 11.1 305 4 304 165 -2.7 0 -2.6 -2.8 04/14/2006 19:50:00 19.9 1.3 22.6 15.6 19.9 1.3 22.6 15.6 17 2.7 21.8 10.7 308 5 304 165 -2.9 0 -2.6 -3 04/14/2006 20:00:00 17.6 1.3 21 14.1 17.6 1.4 21 13.7 14.8 2.2 21 10.3 306 6 301 165 -3 0 -2.8 -3.3 04/14/2006 20:10:00 19.1 2.6 24 12.6 19.1 2.6 24 12.6 16 2.7 24 9.5 306 6 310 165 -3.1 0 -2.8 -3.3 04/14/2006 20:20:00 21.5 1.7 24.8 16.8 21.5 1.7 24.8 16.4 17.3 2.1 22.6 11.8 303 5 304 165 -3 0 -2.8 -3.3 04/14/2006 20:30:00 20.7 1.7 24.4 15.6 20.6 1.7 24.4 15.6 17.5 2.4 24 11.5 306 5 307 165 -3 0 -2.8 -3.3 04/14/2006 20:40:00 21.1 1.6 24.8 16.1 21 1.6 24.4 16.1 18.6 1.9 23.3 13 309 5 307 165 -3 0 -2.8 -3.3 04/14/2006 20:50:00 21.7 1.7 25.6 17.6 21.7 1.7 25.6 16.8 19.3 2.1 24 13 307 5 310 165 -3 0 -2.8 -3 04/14/2006 21:00:00 22.9 1.1 25.6 19.1 22.9 1.2 25.2 19.1 20.2 1.7 24.8 14.1 308 4 305 165 -3 0 -2.8 -3 04/14/2006 21:10:00 20.5 1.6 24 16.8 20.5 1.6 24 16.4 18 2.3 24 11.1 307 5 307 165 -3 0 -2.8 -3.3 04/14/2006 21:20:00 20.1 1.7 23.7 15.3 20 1.7 24 14.9 17.3 2.2 22.9 12.2 307 5 302 165 -3 0 -2.8 -3.3 04/14/2006 21:30:00 20.5 1.8 25.6 15.6 20.4 1.8 25.6 15.3 19.1 2.5 26 12.6 311 6 316 165 -2.8 0 -2.6 -2.8 04/14/2006 21:40:00 20.5 1.5 22.9 16.1 20.4 1.5 23.3 15.6 18.5 2.1 23.7 13.3 310 5 309 165 -2.9 0 -2.8 -3 04/14/2006 21:50:00 20.3 1.6 24 15.6 20.2 1.6 24 15.6 18.7 2.4 26 12.6 311 6 310 165 -2.9 0 -2.8 -3 04/14/2006 22:00:00 20.1 1.7 24 15.6 20 1.7 24 15.6 18.4 1.7 22.9 12.2 311 6 302 165 -2.9 0 -2.8 -3 04/14/2006 22:10:00 21.1 1.5 25.6 16.1 21.1 1.5 25.2 16.1 19.1 1.9 25.2 14.1 309 5 312 165 -2.9 0 -2.6 -3 04/14/2006 22:20:00 20.9 1.5 24.8 16.4 20.9 1.5 24.4 16.8 17.8 1.8 24 13.7 307 5 306 165 -2.9 0 -2.8 -3 04/14/2006 22:30:00 19.9 1.7 23.3 14.9 19.8 1.7 23.7 15.3 17.5 2.2 24 11.5 309 6 319 165 -2.9 0 -2.6 -3 04/14/2006 22:40:00 19.7 1.3 23.7 15.3 19.6 1.3 23.7 16.1 18.2 1.5 22.6 14.1 312 6 310 165 -3 0 -2.8 -3 04/14/2006 22:50:00 20.6 1.3 23.3 17.2 20.5 1.3 23.7 16.8 18 2 22.6 12.2 309 4 309 165 -2.7 0 -2.6 -3 04/14/2006 23:00:00 20.3 1.3 24 16.4 20.3 1.3 24 16.4 18.4 2 22.9 11.8 310 4 307 165 -2.6 0 -2.6 -2.8 04/14/2006 23:10:00 18.3 1.5 22.6 14.5 18.2 1.6 22.1 13.7 15.5 2.3 20.6 10.3 307 6 301 165 -2.6 0 -2.6 -2.8 04/14/2006 23:20:00 18.3 1.7 23.3 13.7 18.2 1.7 22.9 13.7 14.5 2.2 21.8 10.3 304 6 310 165 -2.6 0 -2.6 -2.8 04/14/2006 23:30:00 17.2 2.1 22.1 12.2 17 2.1 21.8 12.6 16 2.2 21.4 8.8 311 6 315 165 -2.8 0 -2.6 -3 04/14/2006 23:40:00 19.7 1.9 24.4 15.3 19.6 1.9 24 15.3 17.6 2.3 23.7 11.8 310 6 305 165 -2.9 0 -2.8 -3 04/14/2006 23:50:00 18.7 1.8 23.7 14.5 18.5 1.7 23.3 14.9 18.2 2.1 23.7 13.3 317 7 321 165 -2.9 0 -2.8 -3 04/15/2006 00:00:00 18.7 1.7 22.6 13.7 18.5 1.7 22.6 13.7 17.7 1.7 22.6 13 316 8 316 165 -2.8 0 -2.6 -3.3 04/15/2006 00:10:00 18.6 1.4 24 15.3 18.3 1.4 22.9 14.9 18.1 1.5 23.3 13.7 320 6 332 165 -2.8 0 -2.6 -3 04/15/2006 00:20:00 18.3 1.7 22.6 13.3 18.1 1.7 22.6 12.6 18 1.7 22.1 12.6 322 7 319 165 -2.6 0.1 -2.6 -3 04/15/2006 00:30:00 16.5 2.6 23.7 9.9 16.5 2.6 24 10.3 16.1 2.6 24.4 11.1 324 11 302 165 -2.2 0.1 -1.9 -2.6 04/15/2006 00:40:00 17.1 2.5 23.3 10.3 16.9 2.4 22.6 10.3 16.3 2.4 21 10.3 317 8 309 165 -2 0.1 -1.9 -2.4 04/15/2006 00:50:00 15.7 1.8 19.9 11.5 15.5 1.8 19.9 11.5 15.3 1.9 21 9.1 321 9 310 165 -2 0 -1.7 -2.1 04/15/2006 01:00:00 16.5 1.6 20.6 11.8 16.3 1.6 20.6 11.5 14.7 1.5 17.9 10.7 312 7 301 165 -2 0 -1.9 -2.1 04/15/2006 01:10:00 17.7 1.8 21.4 12.2 17.5 1.7 21.4 12.6 16 1.9 20.2 9.5 313 7 312 165 -2.1 0 -1.9 -2.1 04/15/2006 01:20:00 16.7 1.7 21 12.2 16.5 1.7 21 12.2 14.9 1.9 19.9 9.5 311 6 308 165 -2.4 0 -2.1 -2.6 04/15/2006 01:30:00 18.5 2 24 14.5 18.3 2 24.4 14.5 15.9 2.3 23.3 10.3 307 7 310 165 -2.5 0 -2.4 -2.6 04/15/2006 01:40:00 20.2 2.7 26.3 13.3 20 2.7 26 13 18.2 2.9 24.4 11.1 312 7 316 165 -2.4 0.1 -1.9 -2.6 04/15/2006 01:50:00 21.8 2.5 27.5 15.6 21.7 2.5 27.5 14.9 20.3 2.6 27.5 12.2 313 7 305 165 -1.9 0 -1.7 -2.1 04/15/2006 02:00:00 22.2 2.1 26.8 16.4 22.1 2.1 26.8 16.1 21.3 2.4 26.8 14.5 314 6 312 165 -1.9 0.1 -1.7 -2.1 04/15/2006 02:10:00 21.4 2.6 29.1 15.6 21.3 2.6 28.7 15.6 20.2 2.7 27.1 14.1 312 6 304 165 -2.1 0 -1.9 -2.4 04/15/2006 02:20:00 23.1 2.1 27.5 18.3 23 2.1 27.5 18.7 21.9 2.3 28.3 14.9 314 7 318 165 -2.1 0 -1.9 -2.4 04/15/2006 02:30:00 23.4 1.9 27.5 18.3 23.3 1.9 27.9 17.9 22.3 2 27.9 17.2 312 6 309 165 -2.4 0 -2.1 -2.6 04/15/2006 02:40:00 23 1.9 27.5 18.3 22.9 1.9 27.5 18.3 22 1.9 26.3 16.1 314 6 312 165 -2.5 0 -2.1 -2.6 04/15/2006 02:50:00 24 2.3 31.3 17.2 23.9 2.3 30.9 17.9 23.2 2.6 28.7 16.8 315 6 305 165 -2.5 0 -2.1 -2.6 04/15/2006 03:00:00 27 2.2 33.2 21.4 26.8 2.3 32.9 21 27 2.5 33.6 21 317 5 313 165 -2.2 0.1 -1.9 -2.6 04/15/2006 03:10:00 28.1 1.9 33.2 22.6 28 1.9 33.2 22.9 28 2.2 33.2 22.1 316 5 319 165 -2.3 0 -2.1 -2.6 04/15/2006 03:20:00 26.5 1.8 30.9 21.8 26.4 1.8 30.9 21.8 26.2 2.2 31.8 20.2 314 5 318 165 -2.5 0 -2.4 -2.6 04/15/2006 03:30:00 23 2.5 28.3 16.8 22.9 2.5 28.3 16.8 21.9 2.4 27.5 13.3 313 7 302 165 -2.5 0 -2.4 -2.6 04/15/2006 03:40:00 23.5 2.2 28.3 17.6 23.4 2.2 28.7 16.4 23 2.3 29.1 17.2 316 6 306 165 -2.1 0.1 -1.9 -2.6 04/15/2006 03:50:00 24 2 29.4 17.2 23.8 2 29.1 17.2 23.1 2 29.1 17.6 315 7 309 165 -2 0 -1.9 -2.1 04/15/2006 04:00:00 25 1.7 28.7 19.9 24.9 1.7 28.7 19.9 23.6 2 27.9 17.9 311 5 305 165 -2 0 -1.9 -2.1 04/15/2006 04:10:00 23.5 1.3 26.3 19.5 23.4 1.4 26.3 19.1 22.4 1.5 25.6 17.9 313 5 312 165 -2.1 0 -1.9 -2.1 04/15/2006 04:20:00 24.8 1.1 27.5 20.6 24.7 1.2 27.5 21 24.1 1.5 27.5 18.7 312 4 312 165 -2.1 0 -1.9 -2.6 04/15/2006 04:30:00 24.7 1.6 29.1 20.6 24.6 1.6 29.1 20.6 24.6 1.9 30.2 18.7 315 5 316 165 -2.1 0 -1.9 -2.4 04/15/2006 04:40:00 25 1.7 30.2 20.2 25 1.7 30.6 20.2 24.6 2.2 29.4 18.7 314 5 312 165 -1.9 0 -1.7 -2.1 04/15/2006 04:50:00 23.5 1.6 27.9 19.5 23.4 1.7 27.9 19.1 23.1 1.6 27.5 18.7 314 5 313 165 -1.9 0 -1.7 -2.1 04/15/2006 05:00:00 24.2 1.5 27.5 20.2 24.1 1.6 27.1 19.9 23.2 1.6 27.5 16.8 312 4 308 165 -1.9 0 -1.7 -1.9 04/15/2006 05:10:00 24.7 1.7 28.3 20.2 24.7 1.7 28.3 19.9 24.1 1.8 27.9 17.6 314 6 310 165 -1.8 0 -1.7 -2.1 04/15/2006 05:20:00 24.8 1.5 28.3 20.2 24.7 1.5 28.3 20.2 24.1 1.8 30.9 18.7 313 5 304 165 -2 0 -1.7 -2.1 04/15/2006 05:30:00 24.7 1.4 27.9 19.5 24.6 1.5 27.9 19.9 23.1 1.7 27.9 16.8 310 5 312 165 -2.2 0 -1.9 -2.6 04/15/2006 05:40:00 23.9 1.7 27.5 19.1 23.9 1.7 27.5 19.1 23 1.7 27.1 17.9 313 6 310 165 -2.2 0 -2.1 -2.6 04/15/2006 05:50:00 22.4 1.6 26.8 18.3 22.3 1.7 26.3 17.9 21.6 2 25.6 14.5 312 5 307 165 -2.2 0 -2.1 -2.6 04/15/2006 06:00:00 22.7 1.5 26.8 17.2 22.5 1.5 26.3 17.2 21.4 2.3 26.8 15.3 313 7 319 165 -2.1 0 -1.9 -2.6 04/15/2006 06:10:00 23.8 1.9 28.3 18.7 23.7 2 28.7 18.3 23.5 2.1 28.7 15.6 314 6 310 165 -2.1 0 -1.9 -2.1 04/15/2006 06:20:00 25 1.7 29.1 19.9 24.9 1.7 29.1 19.9 23.5 2.3 29.4 17.9 311 6 312 165 -2.2 0 -1.9 -2.4 04/15/2006 06:30:00 25.8 2 30.2 21 25.7 2 30.9 19.9 25.7 2.4 30.9 18.3 315 6 309 165 -2 0 -1.9 -2.4 04/15/2006 06:40:00 27.9 2.1 32.9 21 27.8 2.1 33.2 20.6 27.9 2.5 34.4 17.6 316 4 319 165 -2 0 -1.9 -2.1 04/15/2006 06:50:00 29 1.7 32.9 23.3 29 1.7 32.9 24 29.2 1.9 32.4 21.4 314 4 315 165 -2 0 -1.9 -2.1 04/15/2006 07:00:00 27.4 1.9 32.1 21.8 27.4 2 32.1 21 27.1 2.2 32.4 21.4 313 5 308 165 -2 0 -1.9 -2.1 04/15/2006 07:10:00 24.8 1.7 29.1 19.9 24.6 1.8 29.1 20.2 24.5 2.1 29.4 18.7 316 6 317 165 -2.1 0 -1.9 -2.1 04/15/2006 07:20:00 24.6 1.7 28.7 19.5 24.5 1.7 28.7 18.7 24.3 2.2 28.3 16.8 315 5 311 165 -2.1 0 -1.9 -2.4 04/15/2006 07:30:00 25.1 2.1 30.2 17.9 25 2.1 29.8 17.9 25.2 2.2 30.9 18.3 316 5 319 165 -2.2 0 -2.1 -2.6 04/15/2006 07:40:00 26.7 1.8 31.3 20.6 26.7 1.8 31.3 19.9 26.3 2.2 32.1 17.9 313 5 317 165 -2.5 0 -2.4 -2.6 04/15/2006 07:50:00 28.7 1.9 33.2 23.7 28.6 2 33.2 23.7 28.7 2.2 34 23.3 316 4 312 165 -2.5 0 -2.4 -2.8 04/15/2006 08:00:00 27.2 2.4 32.9 20.2 27 2.4 33.2 20.6 27.2 2.6 34.8 19.5 318 7 316 165 -2.4 0 -2.1 -2.6 04/15/2006 08:10:00 24.7 1.9 29.1 19.5 24.5 1.9 29.1 19.9 24.2 2.2 29.1 14.5 317 6 311 165 -2.3 0 -2.1 -2.6 04/15/2006 08:20:00 26.7 2.2 32.1 19.1 26.6 2.2 32.1 19.9 26.8 2.3 32.4 20.2 316 5 318 165 -2.3 0 -2.1 -2.6 04/15/2006 08:30:00 25.8 1.6 29.8 21 25.7 1.7 29.8 21 25.5 1.7 29.8 19.5 315 6 316 165 -2.4 0 -2.1 -2.6 04/15/2006 08:40:00 26 1.5 31.3 21 26 1.6 31.3 20.6 25.5 1.9 30.6 19.1 312 5 312 165 -2.5 0 -2.4 -2.6 04/15/2006 08:50:00 24.3 2.6 30.2 17.2 24.3 2.7 30.6 16.8 23.5 2.8 29.1 16.1 313 7 310 165 -2.5 0 -2.4 -2.6 04/15/2006 09:00:00 22.8 1.6 27.1 19.1 22.7 1.7 27.5 19.1 21.8 1.7 25.6 16.4 313 6 305 165 -2.5 0 -2.1 -2.6 04/15/2006 09:10:00 24.9 1.6 29.1 20.2 24.8 1.7 28.7 20.2 24.4 1.9 29.4 19.9 313 6 309 165 -2.5 0 -2.4 -2.8 04/15/2006 09:20:00 23.8 1.4 27.1 19.9 23.7 1.5 27.5 19.5 23.1 1.7 26.8 19.1 312 5 310 165 -2.8 0 -2.6 -2.8 04/15/2006 09:30:00 21.7 1.5 25.2 17.2 21.6 1.5 24.8 17.2 20.3 2 24.4 15.3 311 5 309 165 -2.8 0 -2.6 -2.8 04/15/2006 09:40:00 19.7 1.4 22.9 14.1 19.6 1.5 22.6 13.7 18 2.1 22.9 12.6 311 5 302 165 -2.6 0 -2.6 -2.8 04/15/2006 09:50:00 19.2 1.6 23.7 14.1 19.1 1.6 22.9 14.1 17.8 2.4 22.6 11.1 312 6 320 165 -2.5 0 -2.4 -2.6 04/15/2006 10:00:00 20.9 1.6 24.8 15.6 20.8 1.7 24.4 15.6 19.9 2 24 14.1 312 5 306 165 -2.5 0 -2.4 -2.6 04/15/2006 10:10:00 21.1 1.4 24.8 17.2 21 1.4 24.8 17.6 20.3 1.7 24 14.5 315 5 309 165 -2.3 0 -2.1 -2.6 04/15/2006 10:20:00 23.2 1.3 25.6 17.2 23.2 1.3 26 17.2 22.1 1.7 26 17.6 312 4 312 165 -2.3 0 -2.1 -2.6 04/15/2006 10:30:00 22.1 1.2 24.4 17.6 21.9 1.3 24.4 17.6 21.4 1.8 25.2 14.5 314 5 315 165 -2.2 0 -2.1 -2.6 04/15/2006 10:40:00 20.3 1.5 23.7 14.9 20.2 1.5 23.7 15.3 16.5 1.9 21 11.5 306 6 302 165 -2 0 -1.7 -2.1 04/15/2006 10:50:00 17.9 1.7 21.8 13 17.8 1.7 21.8 12.6 15.6 2.6 22.6 9.5 309 8 300 165 -1.6 0.1 -1.4 -1.9 04/15/2006 11:00:00 18.2 1.7 21.8 12.6 18.2 1.7 21.4 12.6 15.5 2.4 22.1 10.3 307 7 308 165 -1.5 0 -1.2 -1.7 04/15/2006 11:10:00 17.9 1.6 21.4 13.3 17.9 1.7 21.8 13.3 14.1 1.7 18.7 9.9 304 6 300 165 -1.6 0 -1.4 -1.7 04/15/2006 11:20:00 18.9 1.4 22.6 14.9 18.8 1.4 22.1 14.9 15.7 2 20.2 10.7 307 5 309 165 -1.6 0 -1.4 -1.9 04/15/2006 11:30:00 17.2 1.5 21 13 17.1 1.5 21.4 13 15.2 1.8 20.2 10.7 310 6 311 165 -1.5 0.1 -1.2 -1.9 04/15/2006 11:40:00 19.3 1.2 21.8 15.6 19.3 1.3 21.8 14.9 15.5 1.6 20.2 11.1 307 4 304 165 -1.4 0 -1.2 -1.4 04/15/2006 11:50:00 20 1.7 23.7 13.3 19.8 1.7 23.3 13 19.3 2.1 23.7 12.6 316 6 317 165 -1.3 0 -1 -1.4 04/15/2006 12:00:00 18.7 1.7 24.4 13.7 18.5 1.7 24.4 13.7 18.2 1.9 25.2 12.2 318 7 321 165 -1.1 0 -0.8 -1.4 04/15/2006 12:10:00 18.9 1.7 23.3 14.5 18.7 1.7 23.3 14.1 18.3 2.1 22.9 11.8 317 7 314 165 -0.9 0 -0.8 -1.2 04/15/2006 12:20:00 15.3 1.9 20.2 8.4 15 1.9 19.9 6.8 15 1.8 21 9.5 323 8 329 165 -0.5 0.2 -0.3 -0.8 04/15/2006 12:30:00 15.2 2 20.6 9.9 15.1 2 20.6 9.9 14.6 2 20.6 9.9 320 9 314 165 -0.3 0.1 0.2 -0.5 04/15/2006 12:40:00 16.3 2.5 22.9 10.3 16.1 2.4 22.9 10.3 15 2.5 21.4 8.4 313 8 298 165 -0.4 0.1 -0.1 -0.8 04/15/2006 12:50:00 17.4 2.1 23.3 11.8 17.2 2.1 23.3 11.5 16.2 1.9 22.9 11.8 318 9 308 165 -0.6 0.1 -0.5 -0.8 04/15/2006 13:00:00 17.5 1.9 21.8 12.2 17.4 1.9 21.8 13 16.4 2 21.4 10.7 316 9 306 165 -0.6 0.1 -0.3 -0.8 04/15/2006 13:10:00 17.9 2.3 24 13.3 17.8 2.3 23.7 11.8 16.3 2.3 23.3 11.5 312 7 307 165 -0.7 0.1 -0.5 -1 04/15/2006 13:20:00 20.9 1.8 24.4 15.3 20.8 1.8 24.4 15.3 19.9 2.4 24 13 313 5 314 165 -1 0 -0.8 -1.2 04/15/2006 13:30:00 19.3 2 24.4 14.5 19.1 2 24.4 14.1 18.7 2.1 23.7 12.6 321 9 304 165 -0.9 0.1 -0.5 -1.2 04/15/2006 13:40:00 20.3 2.2 27.1 14.5 20.2 2.2 26.8 14.5 19.6 1.9 24.8 14.9 319 9 310 165 -0.7 0 -0.5 -0.8 04/15/2006 13:50:00 18.8 2 23.3 12.2 18.7 2 23.7 12.6 17.8 2.2 24.4 12.2 316 9 312 165 -0.6 0 -0.5 -0.8 04/15/2006 14:00:00 17.2 2.1 23.3 12.2 17.1 2.1 23.3 11.8 16.4 2 21.4 11.1 317 9 318 165 -0.6 0 -0.5 -0.8 04/15/2006 14:10:00 16.4 1.8 21.4 12.6 16.3 1.8 21 12.2 15.6 2.2 23.3 11.1 318 9 307 165 -0.5 0 -0.1 -0.8 04/15/2006 14:20:00 13.8 1.9 20.2 9.1 13.6 1.9 20.2 8.8 12.9 2.2 18.3 8.4 323 15 312 165 -0.1 0.1 0.2 -0.5 04/15/2006 14:30:00 11 1.8 15.6 6.5 10.9 1.8 16.1 6.5 9.8 2.1 16.1 4.6 310 12 317 165 0.1 0.1 0.7 -0.8 04/15/2006 14:40:00 8.4 2.1 13.7 3.4 8.1 2.1 13.7 3.4 7.4 1.7 11.8 3 323 24 304 165 0.7 0.3 1.4 -0.1 04/15/2006 14:50:00 7.8 1.4 11.5 4.6 7.9 1.4 11.1 4.2 7 1.5 11.5 3 303 15 297 165 0.4 0.3 1.4 -0.1 04/15/2006 15:00:00 10.1 1.2 14.9 7.2 9.9 1.3 14.9 6.8 9.9 1.1 13.7 7.2 331 11 338 165 0.5 0.2 0.9 -0.3 04/15/2006 15:10:00 10.7 1.3 14.5 6.8 10.6 1.3 14.1 7.2 10.3 1.3 14.1 7.2 323 11 333 165 0.5 0.2 0.9 0.2 04/15/2006 15:20:00 11.6 1.5 15.6 7.2 11.5 1.4 15.3 7.2 10.5 1.4 14.9 6.1 316 14 299 165 0.2 0.3 0.7 -0.8 04/15/2006 15:30:00 12.1 1.2 15.3 9.1 12 1.2 15.6 8.8 10.8 1.5 15.3 7.2 313 8 304 165 0.1 0 0.2 -0.5 04/15/2006 15:40:00 12.4 1.2 16.8 9.5 12.3 1.3 16.4 8.8 11.9 1.2 16.4 8.8 328 13 313 165 0.3 0.2 0.9 -0.3 04/15/2006 15:50:00 13.1 1.4 18.3 9.5 13 1.4 18.7 9.5 12.5 1.5 17.6 8.4 322 10 315 165 0.5 0.2 0.9 0.2 04/15/2006 16:00:00 16 2 20.6 11.1 15.8 2 21 11.5 15.3 2.1 19.9 10.3 321 10 297 165 0.2 0.2 0.9 -0.3 04/15/2006 16:10:00 13.3 1.8 18.3 9.1 13.2 1.8 18.3 8.8 12.9 1.6 17.9 8.8 327 13 304 165 0.3 0.1 0.7 -0.3 04/15/2006 16:20:00 15.7 1.3 18.7 12.2 15.4 1.3 18.7 11.5 15.2 1.5 18.3 10.7 323 6 323 165 0.1 0 0.2 -0.1 04/15/2006 16:30:00 15.9 1.6 19.1 11.8 15.6 1.5 19.1 11.5 15.2 1.8 19.1 11.5 324 7 321 165 0.2 0.1 0.7 -0.1 04/15/2006 16:40:00 16.9 1.7 19.9 11.8 16.6 1.6 19.5 11.8 16.4 1.9 20.2 11.5 325 6 329 165 0.1 0 0.2 -0.1 04/15/2006 16:50:00 14.8 1.6 18.3 10.7 14.5 1.5 17.6 9.9 14.2 1.8 17.9 9.9 323 8 320 165 0 0 0.2 -0.3 04/15/2006 17:00:00 15.6 1.5 18.3 10.3 15.3 1.5 17.9 10.3 14.8 1.5 17.9 9.1 318 5 312 165 -0.3 0.1 0.2 -0.5 04/15/2006 17:10:00 13.9 1.5 17.2 9.1 13.7 1.5 16.8 8.8 13 1.7 17.6 8.8 319 9 322 165 -0.4 0 -0.3 -0.5 04/15/2006 17:20:00 11.5 1.6 15.6 7.2 11.4 1.6 14.9 7.2 10.7 1.9 14.9 6.1 320 9 332 165 -0.2 0 -0.1 -0.5 04/15/2006 17:30:00 9.5 1.5 13.7 5.7 9.4 1.6 13.7 5.3 8.7 1.4 12.6 5.7 322 17 312 165 0.1 0.1 0.2 -0.3 04/15/2006 17:40:00 10.4 1.7 13.3 5.7 10.3 1.7 13.3 6.1 9.3 1.9 12.6 4.2 318 10 314 165 0.2 0 0.4 -0.1 04/15/2006 17:50:00 11.9 1 14.5 8.8 12 1 14.5 9.1 11 1.1 14.1 6.8 314 5 318 165 -0.1 0 0.2 -0.3 04/15/2006 18:00:00 10.5 1.2 13 5.7 10.5 1.2 13.7 6.5 9.5 1.3 13 5.7 316 7 311 165 -0.1 0 0.2 -0.3 04/15/2006 18:10:00 9.4 1.1 12.6 6.5 9.3 1 12.2 6.5 8.5 1.4 11.5 4.6 317 9 335 165 -0.2 0.1 -0.1 -0.3 04/15/2006 18:20:00 9.9 1.5 13.7 5.3 9.8 1.5 13.7 4.9 8.9 1.7 12.2 4.2 315 10 313 165 -0.3 0 -0.1 -0.5 04/15/2006 18:30:00 9.9 1.3 13.7 6.1 9.8 1.3 13.3 6.5 9.1 1.3 12.2 4.9 315 8 322 165 -0.6 0 -0.5 -0.8 04/15/2006 18:40:00 11.3 1.4 15.6 8.4 11.2 1.4 15.3 8.4 10.5 1.4 13.7 6.1 315 9 302 165 -0.9 0.1 -0.5 -1.2 04/15/2006 18:50:00 9.8 1.1 12.6 6.8 9.7 1.2 12.2 6.5 9.4 1.2 12.6 6.1 327 11 319 165 -0.9 0 -0.8 -1.2 04/15/2006 19:00:00 8.1 1.3 11.8 4.6 7.8 1.4 11.1 3.8 7.6 1.5 11.1 3 335 13 347 165 -1 0 -0.8 -1.2 04/15/2006 19:10:00 8.3 1.2 11.1 5.7 8.1 1.2 11.1 5.7 7.8 1.3 11.5 4.9 326 11 338 165 -1.3 0.1 -1.2 -1.4 04/15/2006 19:20:00 7.6 1.7 12.6 3.8 7.5 1.8 12.2 3.8 7.2 1.7 11.1 3.8 329 12 331 165 -1.5 0 -1.2 -1.7 04/15/2006 19:30:00 8.8 1.6 13.7 4.9 8.8 1.6 13 5.3 8.2 1.6 12.6 4.6 318 12 310 165 -1.1 0.1 -0.8 -1.4 04/15/2006 19:40:00 9.9 1.8 14.5 5.7 9.8 1.8 14.5 5.7 9 1.7 13.7 4.9 318 15 298 165 -1 0 -0.8 -1.2 04/15/2006 19:50:00 7.8 2.3 13 1.9 7.2 2.5 13.3 1.9 7.6 2.2 13 1.5 347 16 344 165 -1.4 0.2 -0.8 -1.7 04/15/2006 20:00:00 3.9 1.3 8.4 1.1 3.5 1.4 8 0.7 3.6 1.3 8 1.1 340 23 331 165 -1.8 0 -1.4 -1.9 04/15/2006 20:10:00 5.9 1.3 11.1 2.6 5.4 1.2 9.1 2.6 5.7 1.5 11.1 2.6 339 22 8 165 -1.9 0.2 -1.4 -2.4 04/15/2006 20:20:00 4.7 1.4 8.4 1.5 4.7 1.5 8.8 1.9 4.1 1.4 8 0.7 300 19 290 165 -2.1 0 -1.9 -2.1 04/15/2006 20:30:00 5.8 1.4 9.9 3.4 5.8 1.4 9.9 3 5.1 1.2 8.4 2.6 306 13 302 165 -2 0.1 -1.7 -2.1 04/15/2006 20:40:00 2.6 0.9 4.6 0.7 2 1 4.2 0.4 2.4 0.8 4.6 0.4 347 20 6 165 -2.2 0.1 -2.1 -2.6 04/15/2006 20:50:00 1.2 0.8 4.2 0.4 1.1 0.7 3.8 0.4 1.1 0.7 2.6 0.4 351 45 41 165 -2.4 0 -2.1 -2.6 04/15/2006 21:00:00 3.3 1 5.3 1.5 2.8 0.8 4.9 1.1 3.1 1 5.7 1.5 333 17 4 165 -2.5 0 -2.1 -2.6 04/15/2006 21:10:00 2.5 0.5 3.4 1.1 2.4 0.5 3.4 0.7 2.4 0.5 3.4 1.1 310 18 305 165 -2.7 0.1 -2.4 -3 04/15/2006 21:20:00 3.5 1.5 6.5 0.7 3.4 1.5 6.5 0.4 2.9 1.1 5.7 0.4 292 14 295 165 -3 0 -2.8 -3.3 04/15/2006 21:30:00 4.2 0.8 6.8 2.6 4.1 0.8 6.5 2.3 3.4 0.6 5.7 1.9 305 8 303 165 -3.2 0.1 -2.8 -3.3 04/15/2006 21:40:00 6.2 1.1 8.8 3.8 6 1.1 8.4 3.8 5.5 1 7.6 3 312 9 313 165 -2.9 0 -2.8 -3 04/15/2006 21:50:00 4.7 0.8 7.2 3 4.6 0.7 6.8 3 4.3 0.9 6.5 2.3 317 14 311 165 -3 0 -2.8 -3.3 04/15/2006 22:00:00 6.3 1 8.8 3.8 6.2 1 8.4 3.8 5.6 1.2 8 3 312 9 304 165 -2.9 0 -2.6 -3 04/15/2006 22:10:00 6.2 1 8.4 3.8 6.1 1 8.8 3.8 4.8 0.9 7.2 2.6 305 5 306 165 -2.9 0.1 -2.6 -3 04/15/2006 22:20:00 5.1 0.7 6.5 3.4 4.9 0.7 6.5 3.4 4.5 0.6 6.1 3 312 6 310 165 -3.2 0 -2.8 -3.5 04/15/2006 22:30:00 4.4 0.7 6.5 3 4.2 0.8 6.5 2.6 3.9 0.6 5.7 2.6 310 8 308 165 -3.2 0.2 -2.8 -3.5 04/15/2006 22:40:00 2.5 1.2 4.9 0.4 2.2 1.3 4.6 0.4 2.5 1 4.6 0.7 353 33 319 165 -3 0.2 -2.6 -3.3 04/15/2006 22:50:00 0.9 0.5 2.3 0.4 0.7 0.4 2.3 0.4 1.2 0.4 2.3 0.4 106 36 62 165 -2.6 0 -2.6 -2.8 04/15/2006 23:00:00 0.9 0.5 1.9 0.4 0.7 0.4 1.9 0.4 0.9 0.5 1.9 0.4 77 56 27 165 -2.6 0 -2.4 -2.8 04/15/2006 23:10:00 1.6 0.6 2.6 0.4 1.4 0.6 2.3 0.4 1.7 0.4 2.6 1.1 111 38 154 165 -2.9 0.1 -2.6 -3 04/15/2006 23:20:00 2.4 0.4 3 1.5 2.1 0.5 3 1.1 2.4 0.4 3 1.5 145 10 147 165 -3 0 -2.8 -3.3 04/15/2006 23:30:00 1 0.7 2.3 0.4 0.7 0.5 1.9 0.4 1 0.6 2.3 0.4 162 1 160 165 -3 0 -2.8 -3 04/15/2006 23:40:00 1 0.6 2.3 0.4 0.7 0.6 2.3 0.4 0.9 0.6 2.3 0.4 264 41 238 165 -3.3 0.1 -2.8 -3.5 04/15/2006 23:50:00 2.1 0.6 3.4 0.7 1.9 0.6 3.4 0.4 2.2 0.5 3.4 0.7 241 7 236 165 -2.9 0.1 -2.6 -3.3 04/16/2006 00:00:00 1.9 0.4 2.6 0.7 1.6 0.4 2.3 0.4 1.7 0.6 2.6 0.7 303 20 320 165 -2.9 0.1 -2.6 -3.3 04/16/2006 00:10:00 2.1 0.6 3 0.7 1.8 0.7 3 0.4 2.2 0.6 3 0.7 339 2 343 165 -3.3 0 -3 -3.5 04/16/2006 00:20:00 0.8 0.4 1.5 0.4 0.4 0.2 1.1 0.4 1 0.4 1.9 0.4 335 7 338 165 -3.4 0 -3 -3.5 04/16/2006 00:30:00 1.3 0.7 2.6 0.4 0.7 0.5 1.9 0.4 1.4 0.8 2.6 0.4 7 7 12 165 -3 0.1 -2.6 -3.3 04/16/2006 00:40:00 0.4 0 0.7 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 46 24 63 165 -2.5 0.1 -2.1 -3 04/16/2006 00:50:00 0.7 0.4 1.5 0.4 0.4 0.2 1.1 0.4 0.6 0.4 1.5 0.4 85 39 113 165 -2.7 0.1 -2.6 -3 04/16/2006 01:00:00 1.3 0.5 2.3 0.4 0.8 0.6 1.9 0.4 1.1 0.6 2.6 0.4 118 32 148 165 -3 0 -2.8 -3.3 04/16/2006 01:10:00 1.6 0.5 2.6 0.7 1.1 0.6 2.3 0.4 1.6 0.5 2.3 0.7 144 3 146 165 -3.1 0 -2.8 -3.3 04/16/2006 01:20:00 1.8 0.3 2.6 1.1 1.3 0.4 2.3 0.4 1.8 0.3 2.6 1.5 161 7 162 165 -3 0 -2.8 -3 04/16/2006 01:30:00 1.8 0.2 2.3 1.5 1.3 0.3 1.9 0.4 1.8 0.2 2.3 1.5 169 10 175 165 -2.9 0 -2.8 -3.3 04/16/2006 01:40:00 1.8 0.3 2.3 1.1 1.2 0.4 1.9 0.4 1.7 0.3 2.6 1.1 164 2 164 165 -2.9 0 -2.8 -3 04/16/2006 01:50:00 0.7 0.4 1.9 0.4 0.4 0.1 1.1 0.4 0.6 0.3 1.5 0.4 164 0 164 165 -3.2 0 -2.8 -3.3 04/16/2006 02:00:00 1.4 0.7 2.6 0.4 1.1 0.6 2.3 0.4 1.4 0.7 2.3 0.4 167 4 178 165 -3.1 0.1 -2.8 -3.5 04/16/2006 02:10:00 1.6 0.4 2.6 0.7 1 0.6 2.3 0.4 1.7 0.4 2.6 0.7 173 4 178 165 -3 0 -2.8 -3.3 04/16/2006 02:20:00 1.4 0.3 2.3 0.7 0.5 0.4 1.9 0.4 1.3 0.3 1.9 0.7 163 2 162 165 -3.1 0 -3 -3.3 04/16/2006 02:30:00 2.2 0.4 3 1.5 1.8 0.5 2.6 0.7 2.3 0.4 3 1.5 167 4 166 165 -3.1 0 -3 -3.3 04/16/2006 02:40:00 2.1 0.5 3 1.1 1.6 0.7 2.6 0.4 2.3 0.5 3 1.1 171 5 169 165 -3.2 0 -3 -3.5 04/16/2006 02:50:00 2.4 0.2 3 1.9 2.1 0.2 2.6 1.5 2.6 0.2 3 1.9 166 4 163 165 -3.1 0 -3 -3.3 04/16/2006 03:00:00 3.1 0.6 4.2 1.9 2.8 0.6 3.8 1.5 3.3 0.6 4.2 2.3 170 3 169 165 -3.1 0 -2.8 -3.3 04/16/2006 03:10:00 3.9 0.3 4.6 3 3.6 0.3 4.2 3 3.9 0.4 4.6 3 169 4 165 165 -3.1 0 -2.8 -3.3 04/16/2006 03:20:00 3.9 0.4 4.6 3 3.6 0.3 4.2 2.6 3.9 0.4 4.6 3 168 3 169 165 -3 0 -2.8 -3.3 04/16/2006 03:30:00 4 0.2 4.6 3.4 3.8 0.2 4.2 3.4 4.1 0.3 4.6 3.4 169 4 174 165 -2.9 0 -2.8 -3.3 04/16/2006 03:40:00 3.8 0.4 4.6 3 3.6 0.4 4.6 2.6 3.7 0.4 4.6 2.6 160 6 160 165 -3 0 -2.8 -3.3 04/16/2006 03:50:00 3.7 0.7 5.3 2.3 3.6 0.8 5.3 2.3 3.5 0.6 4.9 2.3 148 5 143 165 -3.1 0 -2.8 -3.3 04/16/2006 04:00:00 3.6 0.9 5.7 1.5 3.5 0.9 5.7 1.1 3.5 0.8 5.3 1.9 148 8 146 165 -3.1 0 -2.8 -3.3 04/16/2006 04:10:00 4.2 0.8 5.7 2.3 4 0.8 5.3 2.3 4 0.7 5.3 2.6 159 7 162 165 -2.9 0 -2.6 -3.3 04/16/2006 04:20:00 5.4 0.5 6.5 3.8 5.2 0.5 6.1 3.8 5.3 0.6 6.5 3.8 159 5 160 165 -2.7 0 -2.6 -2.8 04/16/2006 04:30:00 5.5 0.6 6.5 3.4 5.3 0.6 6.1 3.4 5.4 0.6 6.5 3.8 155 5 155 165 -2.6 0 -2.6 -2.8 04/16/2006 04:40:00 4.2 0.5 5.7 3 4.1 0.4 5.3 3 4.2 0.4 5.7 3 155 7 148 165 -2.5 0 -2.6 -2.8 04/16/2006 04:50:00 4.8 0.4 5.7 3.4 4.7 0.4 5.7 3 4.6 0.4 5.7 3.8 154 5 158 165 -2.5 0 -2.4 -2.8 04/16/2006 05:00:00 5.2 0.4 6.1 4.2 5.1 0.4 6.1 3.8 5.1 0.4 6.1 4.2 151 4 152 165 -2.2 0 -2.1 -2.6 04/16/2006 05:10:00 5.4 0.4 6.8 4.2 5.3 0.4 6.8 4.2 5.4 0.4 6.8 4.2 156 6 150 165 -2 0 -1.9 -2.1 04/16/2006 05:20:00 5.3 0.6 7.2 4.2 5.1 0.6 6.8 3.8 5.2 0.6 7.2 3.8 154 5 151 165 -2 0 -1.9 -2.1 04/16/2006 05:30:00 5.3 0.7 7.2 3.4 5.1 0.7 6.8 3.4 5.1 0.7 7.2 3.4 156 7 165 165 -1.8 0 -1.7 -2.1 04/16/2006 05:40:00 4.7 0.6 6.1 3 4.6 0.5 5.7 3 4.6 0.5 6.1 3 152 6 148 165 -1.8 0 -1.4 -1.9 04/16/2006 05:50:00 5.3 0.8 7.2 3.4 5.1 0.8 7.2 3.4 4.9 0.6 6.5 3.4 149 5 156 165 -1.6 0 -1.4 -1.9 04/16/2006 06:00:00 5.2 0.6 6.8 3.8 5 0.6 6.8 3.8 5 0.6 6.5 3.8 152 6 156 165 -1.4 0 -1.2 -1.4 04/16/2006 06:10:00 5.7 0.7 7.6 4.6 5.5 0.7 7.6 4.2 5.6 0.6 7.2 4.2 152 5 145 165 -1.4 0 -1.2 -1.4 04/16/2006 06:20:00 6 0.9 8.4 3.8 5.9 0.8 8 4.2 6 0.9 8.4 3.4 153 9 164 165 -1.2 0 -1 -1.2 04/16/2006 06:30:00 6.6 1.1 8.8 4.2 6.5 1 8.4 4.2 6.5 1.1 8.8 4.6 159 6 162 165 -1 0 -0.8 -1.2 04/16/2006 06:40:00 6.4 0.7 8 4.9 6.3 0.7 8 4.6 6.4 0.7 8 4.9 156 6 145 165 -1.1 0 -1 -1.2 04/16/2006 06:50:00 6.1 0.6 7.6 4.6 5.9 0.6 7.2 4.2 6.1 0.6 8 4.6 153 7 156 165 -1.2 0 -1 -1.2 04/16/2006 07:00:00 6.4 0.6 8 4.6 6.2 0.6 7.6 4.2 6.3 0.6 7.6 4.6 155 5 153 165 -1.4 0 -1.2 -1.4 04/16/2006 07:10:00 5.7 0.6 7.6 4.6 5.5 0.6 7.2 4.2 5.6 0.5 7.2 4.6 160 4 162 165 -1.6 0 -1.4 -1.9 04/16/2006 07:20:00 7 0.8 9.1 5.3 6.7 0.8 8.8 5.3 6.9 0.7 8.4 5.3 163 6 165 165 -1.7 0 -1.4 -1.9 04/16/2006 07:30:00 6.9 0.9 9.9 5.3 6.6 0.8 9.1 4.9 6.9 0.8 8.8 4.9 161 11 165 165 -1.7 0 -1.4 -1.9 04/16/2006 07:40:00 7.6 0.6 9.9 6.1 7.3 0.6 9.1 6.1 7.5 0.6 9.5 6.5 164 12 164 165 -1.7 0 -1.4 -1.9 04/16/2006 07:50:00 8.1 0.8 9.9 6.1 7.8 0.8 9.5 6.1 8.2 0.9 9.9 6.5 166 4 179 165 -1.6 0 -1.4 -1.7 04/16/2006 08:00:00 9.2 0.8 11.5 7.6 8.8 0.8 10.7 7.2 9.3 0.8 11.1 7.2 167 7 166 165 -1.3 0 -1.2 -1.4 04/16/2006 08:10:00 10.1 0.7 11.8 8.4 9.8 0.6 11.1 8 10.1 0.7 11.8 7.6 163 8 164 165 -1.4 0.1 -1.2 -1.7 04/16/2006 08:20:00 10 0.6 11.5 8 9.7 0.5 11.1 7.6 10 0.6 11.8 8 164 13 167 165 -1.8 0 -1.7 -1.9 04/16/2006 08:30:00 9.4 0.6 11.1 8 9.2 0.6 10.7 7.6 9.6 0.7 11.1 7.2 164 10 165 165 -1.7 0 -1.4 -1.9 04/16/2006 08:40:00 10.1 0.8 12.6 7.6 9.9 0.7 11.8 8 10.3 0.9 12.6 8 163 6 167 165 -1.5 0 -1.2 -1.7 04/16/2006 08:50:00 9.9 1 12.2 7.6 9.7 0.9 11.8 7.6 10 1.1 12.2 7.2 166 7 164 165 -1.6 0 -1.4 -1.7 04/16/2006 09:00:00 9.8 0.4 11.1 8.8 9.6 0.4 10.7 8.8 10.1 0.5 11.5 9.1 166 14 165 165 -1.5 0 -1.4 -1.9 04/16/2006 09:10:00 9.6 0.6 11.1 8 9.5 0.5 11.1 8 9.8 0.7 11.5 8 160 5 164 165 -1.5 0 -1.4 -1.7 04/16/2006 09:20:00 9.3 0.8 11.5 7.6 9.2 0.7 11.1 7.6 9.4 0.8 11.5 7.2 159 6 159 165 -1.7 0 -1.4 -1.9 04/16/2006 09:30:00 8.7 0.5 9.9 6.8 8.5 0.5 10.3 6.1 8.8 0.6 10.3 6.8 160 5 146 165 -1.5 0 -1.4 -1.7 04/16/2006 09:40:00 9.1 0.5 10.3 7.6 9 0.5 10.7 7.6 9.2 0.6 10.7 7.6 158 5 160 165 -1.6 0 -1.4 -1.7 04/16/2006 09:50:00 8.6 0.5 10.3 6.8 8.5 0.6 9.9 6.8 8.8 0.6 10.3 6.8 153 4 151 165 -1.5 0 -1.4 -1.9 04/16/2006 10:00:00 8 0.4 9.1 7.2 7.9 0.4 8.8 6.8 8.1 0.4 9.1 6.8 155 4 158 165 -1.4 0 -1.2 -1.4 04/16/2006 10:10:00 7.6 0.6 9.5 6.5 7.5 0.6 9.5 6.1 7.7 0.7 9.5 6.1 156 3 154 165 -1.4 0 -1.2 -1.7 04/16/2006 10:20:00 8.1 1 11.8 6.1 8.1 1 11.5 5.7 8 1.2 11.5 5.3 158 4 156 165 -1.3 0 -1 -1.4 04/16/2006 10:30:00 9.9 0.7 11.8 8.4 10 0.7 11.8 8.4 9.9 0.7 11.8 8.4 151 5 152 165 -0.9 0.1 -0.8 -1.4 04/16/2006 10:40:00 10.4 0.7 12.2 8.4 10.6 0.8 12.6 8.4 10.7 0.8 12.6 8.4 151 5 144 165 -0.6 0 -0.5 -0.8 04/16/2006 10:50:00 12.1 0.6 13.7 10.3 12.3 0.6 13.7 10.3 12.2 0.9 14.1 9.9 149 3 149 165 -0.5 0 -0.3 -0.8 04/16/2006 11:00:00 12.9 1 15.6 10.7 13.1 1 15.6 11.1 13.1 1.1 15.6 9.9 150 4 153 165 -0.5 0 -0.3 -0.8 04/16/2006 11:10:00 14 0.8 16.1 11.5 14.2 0.8 16.1 11.8 14.1 1 16.4 11.1 150 4 148 165 -0.4 0.1 -0.3 -0.8 04/16/2006 11:20:00 14.4 0.8 16.4 12.2 14.7 0.8 17.2 12.2 14.6 1 16.8 9.9 151 3 146 165 -0.3 0 -0.3 -0.5 04/16/2006 11:30:00 15.6 1.1 18.7 13 15.7 1.1 19.5 13.3 15.6 1.3 18.7 11.8 147 4 145 165 -0.5 0.1 -0.1 -0.8 04/16/2006 11:40:00 15.8 0.7 17.6 13.7 15.9 0.7 17.6 14.1 15.9 1 17.9 13.3 148 4 144 165 -0.3 0 -0.1 -0.5 04/16/2006 11:50:00 16.9 1.2 19.5 14.1 17.3 1.2 19.9 14.5 17.2 1.3 20.2 14.1 148 5 143 165 -0.3 0 -0.1 -0.5 04/16/2006 12:00:00 16.4 1.1 18.7 13.3 16.7 1.1 19.1 13.7 16.7 1.3 19.9 13.3 148 4 149 165 -0.3 0 -0.1 -0.5 04/16/2006 12:10:00 17.6 1.1 19.9 14.1 18.1 1.1 20.6 14.5 17.9 1.2 20.2 14.5 147 4 147 165 -0.1 0 0.2 -0.3 04/16/2006 12:20:00 17.2 1.3 21 13.7 17.8 1.3 21.4 14.9 17.4 1.5 21.8 12.6 148 5 145 165 -0.2 0 0.2 -0.5 04/16/2006 12:30:00 18.2 1 20.6 15.3 18.9 1.1 21.4 15.6 18.6 1.3 21.4 14.9 148 3 151 165 -0.2 0.1 0.2 -0.3 04/16/2006 12:40:00 18.3 0.9 20.2 16.1 18.9 0.9 21 16.1 18.9 1 21 16.4 148 4 148 165 -0.1 0 0.2 -0.3 04/16/2006 12:50:00 18.5 1 21.4 15.6 19 1.1 22.1 16.1 18.8 1.2 21.4 14.1 147 4 151 165 0 0 0.2 -0.1 04/16/2006 13:00:00 18.4 0.8 21 15.6 19 0.8 22.1 16.1 18.7 1 21.4 15.3 146 4 147 165 -0.1 0 0.2 -0.3 04/16/2006 13:10:00 17.1 1.4 19.9 13 17.6 1.5 21 13.3 17.2 1.7 21 13.3 146 6 145 165 0.1 0.1 0.4 -0.3 04/16/2006 13:20:00 18.2 1.1 20.6 15.3 19.4 1.5 22.6 15.6 19.1 1.5 22.1 14.5 147 5 147 165 0.1 0 0.2 -0.1 04/16/2006 13:30:00 17.8 0.6 18.7 15.3 18.9 0.9 20.6 15.6 18.3 1 20.6 15.3 146 5 143 165 0.2 0.1 0.4 -0.1 04/16/2006 13:40:00 17.8 1.3 20.6 14.1 18.2 1.3 20.6 14.5 17.5 1.3 19.9 14.5 143 5 143 165 0.2 0 0.4 -0.1 04/16/2006 13:50:00 17.3 1.1 20.2 14.1 17 1.1 19.9 14.1 16.5 1.1 19.1 13 142 5 143 165 0.2 0 0.7 0.2 04/16/2006 14:00:00 16.3 1.5 20.2 10.3 16.2 1.3 19.5 11.1 15.7 1.4 19.9 11.1 140 6 136 165 0.3 0.1 0.7 0.2 04/16/2006 14:10:00 17.7 1.3 21 13.7 17.5 1.2 19.9 13.7 16.8 1.3 19.5 12.2 138 6 139 165 0.2 0 0.4 0.2 04/16/2006 14:20:00 18.4 1.3 21.4 14.5 17.2 1.2 19.9 13.3 16.6 1.4 19.5 12.6 139 6 150 165 0.2 0 0.7 0.2 04/16/2006 14:30:00 19 1.7 23.3 14.5 17 1.4 20.2 12.6 16.4 1.7 21.4 12.2 144 0 145 165 0.4 0 0.7 0.2 04/16/2006 14:40:00 20.5 1.7 24.4 16.4 18.4 1.2 21 15.3 19.1 1.5 22.6 13.3 144 0 145 165 0.4 0 0.7 0.2 04/16/2006 14:50:00 18.5 1.3 21 14.5 17.1 1.1 19.1 13.7 17.5 1.4 20.2 12.6 144 0 145 165 0.5 0 0.7 0.2 04/16/2006 15:00:00 18.8 1.2 21.8 15.6 18.8 1.2 21.4 16.1 18.3 1.3 21.4 14.5 144 0 145 165 0.6 0 0.9 0.4 04/16/2006 15:10:00 17.6 1.2 21 13.7 18.1 1.3 21.4 13.3 17.9 1.3 22.1 13.3 144 0 145 165 0.7 0 0.9 0.4 04/16/2006 15:20:00 17.9 1.4 21 13.3 18.3 1.2 21.8 14.5 17.4 1.4 21.4 13.7 144 0 145 165 0.8 0.1 0.9 0.4 04/16/2006 15:30:00 17.6 1.7 22.1 13.3 17.8 1.7 23.3 14.1 16.7 1.7 21.4 11.8 144 0 145 165 0.8 0 0.9 0.7 04/16/2006 15:40:00 18.2 1.3 20.6 14.9 19 1.2 21.4 15.3 17.4 1.4 20.2 13.3 144 0 145 165 0.8 0 0.9 0.7 04/16/2006 15:50:00 18.2 1.3 22.1 14.1 19.2 1.3 22.6 14.9 17.3 1.3 21.4 12.2 145 0 145 165 0.8 0 0.9 0.7 04/16/2006 16:00:00 17.3 1.3 19.9 13.7 18.1 1.4 21 14.9 16.1 1.4 19.1 12.2 145 0 145 165 0.8 0 0.9 0.9 04/16/2006 16:10:00 17.1 1.8 20.6 12.2 17.8 1.7 21.4 13.3 15.7 1.7 19.5 11.1 145 0 145 165 0.9 0 1.1 0.9 04/16/2006 16:20:00 17.1 1.1 19.9 13 17.8 1 20.2 14.5 15.6 1.1 18.7 12.6 145 0 145 165 0.8 0 1.1 0.9 04/16/2006 16:30:00 15 2.7 19.1 8 15.3 1.8 19.1 8 13.1 1.6 16.4 8 145 0 145 165 0.9 0 1.1 0.9 04/16/2006 16:40:00 15.2 2.1 17.6 8.8 16 1.6 19.5 12.2 14.2 1.4 17.2 11.1 145 0 145 165 0.8 0 1.1 0.9 04/16/2006 16:50:00 9.7 2.8 16.4 7.6 13.8 1.6 17.6 7.6 12 1.8 16.8 7.6 145 0 145 165 0.9 0 0.9 0.9 04/16/2006 17:00:00 8.1 0.3 8.8 7.2 13.6 1.4 17.2 8.8 12.1 1.6 16.1 7.6 145 0 145 165 0.8 0 0.9 0.9 04/16/2006 17:10:00 7.8 0.3 8.8 7.2 13.3 1.4 16.4 7.6 11.7 1.6 14.9 7.2 145 0 145 165 0.8 0 0.9 0.9 04/16/2006 17:20:00 7.5 0.2 8.4 7.2 12.3 1.5 16.1 6.8 11 1.4 14.9 7.2 145 0 145 165 0.8 0 0.9 0.9 04/16/2006 17:30:00 10.5 3.1 15.3 7.2 12.8 1.5 16.8 7.6 11.2 1.7 15.6 6.8 145 0 145 165 0.8 0 0.9 0.9 04/16/2006 17:40:00 12.5 1.7 14.9 6.8 12.2 2 16.1 6.8 11 1.8 15.3 6.1 145 0 145 165 0.8 0 0.9 0.9 04/16/2006 17:50:00 10.3 2.6 14.9 6.5 10.9 2 15.3 6.5 10.4 1.5 14.1 5.3 145 0 145 165 0.8 0 0.9 0.7 04/16/2006 18:00:00 7.6 1.4 12.6 6.8 9.1 2.1 13 6.8 10.6 1 13 7.2 145 0 145 165 0.8 0 0.9 0.7 04/16/2006 18:10:00 6.9 0.2 7.2 6.5 10.8 2.5 14.1 5.3 12 1.2 14.5 8 145 0 145 165 0.8 0 1.1 0.7 04/16/2006 18:20:00 6.7 0.2 7.2 6.5 11.8 1.2 14.1 6.8 11.4 1.6 14.9 8 145 0 145 165 1 0 1.4 0.9 04/16/2006 18:30:00 6.5 0.3 7.2 5.7 7.9 1.7 12.6 6.8 8.3 0.3 8.8 7.2 145 0 145 165 1.2 0 1.4 0.9 04/16/2006 18:40:00 5.8 0.4 6.8 4.6 6.8 0.2 7.2 6.1 7.4 0.5 8.4 6.1 145 0 145 165 1.2 0 1.4 1.1 04/16/2006 18:50:00 5.5 0.3 6.5 4.9 6.7 0.2 7.2 6.1 7.2 0.5 8.4 6.1 145 0 145 165 1.1 0 1.4 0.9 04/16/2006 19:00:00 5.5 0.4 6.5 4.6 6.6 0.3 7.2 5.7 7 0.5 8.4 6.1 145 0 145 165 0.5 0 0.9 0.2 04/16/2006 19:10:00 5.8 0.5 6.8 4.9 6.8 0.3 7.2 6.1 7.3 0.6 8.8 5.7 145 0 145 165 0.3 0 0.7 0.2 04/16/2006 19:20:00 5.8 0.5 6.8 4.9 6.8 0.3 7.2 6.1 7.3 0.6 8.8 6.1 145 0 145 165 0.2 0 0.2 -0.1 04/16/2006 19:30:00 6.3 0.4 7.2 5.3 7 0.2 7.2 6.5 8.1 0.4 8.8 6.5 145 0 145 165 -0.1 0 0.2 -0.1 04/16/2006 19:40:00 6.3 0.4 7.2 4.9 7 0.2 7.2 6.5 8.1 0.5 8.8 6.5 145 0 145 165 -0.2 0.1 -0.1 -0.3 04/16/2006 19:50:00 6.3 0.4 7.2 4.9 7 0.2 7.2 6.1 8.1 0.4 8.8 6.5 145 0 145 165 -0.3 0 -0.1 -0.5 04/16/2006 20:00:00 6.1 0.4 6.8 5.3 6.9 0.2 7.2 6.1 7.8 0.5 8.8 6.5 145 0 145 165 -0.3 0 -0.1 -0.5 04/16/2006 20:10:00 6.2 0.4 6.8 4.9 6.9 0.2 7.2 6.5 7.9 0.4 8.8 6.5 145 0 145 165 -0.2 0 -0.1 -0.3 04/16/2006 20:20:00 5.8 0.3 6.8 4.9 6.8 0.2 7.2 6.1 7.4 0.5 8.4 6.1 145 0 145 165 -0.3 0 -0.1 -0.5 04/16/2006 20:30:00 6.3 0.3 6.8 5.7 7 0.2 7.2 6.5 7.9 0.4 8.8 6.8 145 0 145 165 -0.3 0 -0.1 -0.5 04/16/2006 20:40:00 6.5 0.3 6.8 5.3 7 0.2 7.2 6.5 8.1 0.3 8.8 7.2 145 0 145 165 -0.4 0 -0.3 -0.5 04/16/2006 20:50:00 6.4 0.3 7.2 5.3 7 0.2 7.6 6.5 8 0.4 8.8 6.5 145 0 145 165 -0.4 0 -0.3 -0.5 04/16/2006 21:00:00 6.7 0.2 7.2 6.1 7.2 0.2 7.6 6.8 8.4 0.3 9.1 6.8 145 0 145 165 -0.5 0 -0.5 -0.8 04/16/2006 21:10:00 6.7 0.2 7.2 5.7 8.8 2.2 12.6 6.8 8.5 0.6 12.2 6.8 145 0 145 165 -0.5 0 -0.5 -0.8 04/16/2006 21:20:00 6.7 0.2 7.2 6.1 11.8 1.4 14.5 6.8 9.7 1.5 13.7 8 145 0 145 165 -0.6 0 -0.5 -0.8 04/16/2006 21:30:00 6.6 0.2 6.8 6.1 9.1 2.2 13 6.8 8.3 0.3 9.1 7.2 145 0 145 165 -0.5 0 -0.3 -0.8 04/16/2006 21:40:00 6.7 0.2 7.2 6.1 8.3 1.8 13.7 6.8 8.7 0.7 12.6 8 154 12 145 165 -0.5 0 -0.3 -0.8 04/16/2006 21:50:00 6.8 0.2 7.2 6.5 12.1 1.3 14.9 8.4 11.4 1.7 13.7 8.4 168 12 164 165 -0.3 0 -0.1 -0.5 04/16/2006 22:00:00 6.9 0.1 7.2 6.5 13.7 0.8 15.6 11.5 12.8 0.8 14.5 10.7 166 17 163 165 -0.3 0 -0.3 -0.5 04/16/2006 22:10:00 6.7 0.2 7.2 6.5 11.4 1 14.1 8.8 9.6 1.6 13.7 7.6 166 11 164 165 -0.3 0 -0.3 -0.5 04/16/2006 22:20:00 6.7 0.2 7.2 6.1 7.8 1.1 11.8 6.8 8.4 0.2 8.8 7.6 166 9 165 165 -0.4 0 -0.3 -0.5 04/16/2006 22:30:00 6.6 0.2 7.2 6.1 7.2 0.2 7.6 6.8 8.2 0.4 8.8 7.2 166 8 162 165 -0.5 0 -0.3 -0.5 04/16/2006 22:40:00 6.3 0.3 6.8 5.7 7.1 0.2 7.6 6.5 7.8 0.4 8.8 6.5 168 5 165 165 -0.5 0 -0.3 -0.5 04/16/2006 22:50:00 5.9 0.4 6.8 4.9 6.8 0.3 7.2 6.1 7.4 0.6 8.8 6.1 176 5 176 165 -0.5 0 -0.3 -0.8 04/16/2006 23:00:00 5.3 0.3 6.1 4.2 6.4 0.3 6.8 5.3 6.5 0.5 7.6 5.3 175 5 172 165 -0.6 0 -0.5 -0.8 04/16/2006 23:10:00 4.2 0.5 5.3 3 5.2 0.6 6.5 3.8 5.2 0.6 6.8 4.2 177 7 170 165 -0.7 0 -0.5 -0.8 04/16/2006 23:20:00 3.7 0.4 4.6 3 4.5 0.4 5.7 3.4 4.9 0.5 6.8 3.8 191 6 186 165 -0.8 0 -0.5 -1 04/16/2006 23:30:00 2.8 0.6 4.2 1.1 3.4 0.7 4.9 1.9 4.3 0.6 5.7 2.6 202 7 201 165 -0.9 0 -0.8 -1.2 04/16/2006 23:40:00 2.5 0.8 4.6 0.7 3.1 0.8 5.3 1.5 4.1 1 6.8 2.3 202 8 211 165 -0.9 0 -0.8 -1.2 04/16/2006 23:50:00 2.8 0.5 3.8 1.9 3.4 0.5 4.9 2.3 4.5 0.6 5.7 3 202 6 193 165 -1 0 -0.8 -1.2 04/17/2006 00:00:00 2.1 0.5 3 0.7 2.8 0.5 3.8 1.5 3.6 0.6 5.3 1.9 199 5 210 165 -1 0 -0.8 -1.2 04/17/2006 00:10:00 0.5 0.4 2.3 0.4 2 0.4 3 0.7 2.7 0.5 3.8 1.1 196 6 183 165 -1 0 -0.8 -1.2 04/17/2006 00:20:00 0.4 0 0.4 0.4 2.6 0.4 3.4 1.1 3.3 0.4 4.2 2.3 195 5 165 165 -1 0 -0.8 -1.2 04/17/2006 00:30:00 0.4 0 0.4 0.4 3.3 0.6 4.6 1.5 4.2 0.7 6.1 2.3 198 5 165 165 -1 0 -0.8 -1.2 04/17/2006 00:40:00 0.4 0 0.4 0.4 4 0.6 5.7 2.6 4.8 0.6 6.1 3.8 196 7 165 165 -1 0 -1 -1.2 04/17/2006 00:50:00 0.5 0.8 4.6 0.4 4.7 0.6 6.1 3.4 5.3 0.6 6.8 4.2 193 7 204 165 -1.1 0 -0.8 -1.2 04/17/2006 01:00:00 4.5 0.5 6.1 3.4 5.5 0.6 7.2 4.2 6.2 0.6 7.6 4.9 192 6 182 165 -1.1 0 -1 -1.2 04/17/2006 01:10:00 3.8 0.5 4.9 2.3 4.8 0.6 6.1 3 5.5 0.7 7.2 4.2 196 6 200 165 -1.2 0 -1 -1.4 04/17/2006 01:20:00 2.7 0.7 4.2 1.1 3.6 0.8 5.3 1.5 4.4 0.8 6.1 3 201 6 194 165 -1.2 0 -1.2 -1.4 04/17/2006 01:30:00 2.2 0.5 3 0.7 3 0.5 4.2 1.5 3.6 0.6 4.9 2.3 199 6 197 165 -1.3 0 -1.2 -1.4 04/17/2006 01:40:00 2.9 0.3 3.4 2.3 3.8 0.4 4.6 3 4.3 0.4 5.3 3.4 193 3 197 165 -1.2 0 -1.2 -1.4 04/17/2006 01:50:00 2.4 0.3 3 1.9 3.3 0.3 3.8 2.6 3.9 0.3 4.6 3 198 4 198 165 -1.2 0 -1.2 -1.4 04/17/2006 02:00:00 2.6 0.3 3.4 1.9 3.4 0.3 4.2 3 3.8 0.3 4.6 3.4 188 4 189 165 -1.3 0 -1.2 -1.4 04/17/2006 02:10:00 2.5 0.3 3 1.9 3.2 0.3 3.8 2.6 3.3 0.3 4.2 2.6 180 3 180 165 -1.3 0 -1.2 -1.4 04/17/2006 02:20:00 2.8 0.4 3.8 1.9 3.6 0.5 4.9 2.3 4 0.6 5.7 2.6 187 6 197 165 -1.2 0 -1.2 -1.4 04/17/2006 02:30:00 2.9 0.5 4.2 1.9 3.8 0.6 4.9 2.6 4.1 0.5 5.3 3 190 6 184 165 -1.3 0 -1.2 -1.4 04/17/2006 02:40:00 2.7 0.5 4.2 1.5 3.5 0.6 5.3 2.6 3.9 0.6 5.3 2.6 189 7 187 165 -1.3 0 -1.2 -1.4 04/17/2006 02:50:00 2.3 0.4 3.4 1.5 3.1 0.5 4.2 2.3 3.5 0.5 4.9 2.6 193 8 194 165 -1.3 0 -1.2 -1.4 04/17/2006 03:00:00 2.8 0.3 3.4 1.5 3.7 0.3 4.2 2.6 4.3 0.5 5.7 3 197 5 193 165 -1.4 0 -1.2 -1.4 04/17/2006 03:10:00 2.4 0.4 3 1.1 3.1 0.5 4.2 1.9 3.8 0.5 4.9 2.3 199 6 197 165 -1.4 0 -1.2 -1.4 04/17/2006 03:20:00 1 0.6 2.3 0.4 1.6 0.6 3 0.4 2.4 0.6 3.8 1.1 197 9 200 165 -1.4 0 -1.2 -1.4 04/17/2006 03:30:00 0.6 0.4 1.9 0.4 1.1 0.7 2.6 0.4 2.2 0.4 3.4 1.5 195 7 189 165 -1.4 0 -1.2 -1.7 04/17/2006 03:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.6 0.4 2.3 0.4 223 16 165 165 -1.5 0 -1.4 -1.7 04/17/2006 03:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.7 0.4 1.9 0.4 201 9 165 165 -1.5 0 -1.4 -1.7 04/17/2006 04:00:00 0.6 0.3 1.5 0.4 1.3 0.6 2.3 0.4 2.2 0.5 3 1.1 192 5 193 165 -1.4 0 -1.2 -1.7 04/17/2006 04:10:00 0.6 0.3 1.5 0.4 1.2 0.5 2.3 0.4 2.3 0.3 3 1.1 196 4 190 165 -1.5 0 -1.4 -1.7 04/17/2006 04:20:00 0.7 0.4 1.9 0.4 1.3 0.6 2.6 0.4 2.4 0.4 3 1.5 197 6 194 165 -1.4 0 -1.4 -1.4 04/17/2006 04:30:00 0.7 0.5 1.9 0.4 1.1 0.8 2.6 0.4 2.5 0.5 3.8 1.5 202 7 196 165 -1.4 0 -1.2 -1.4 04/17/2006 04:40:00 0.8 0.6 2.3 0.4 1.3 0.8 3 0.4 2.5 0.7 3.8 0.7 199 8 188 165 -1.4 0 -1.2 -1.4 04/17/2006 04:50:00 1.5 0.5 2.3 0.4 2.1 0.5 3 0.7 3 0.4 3.8 1.9 198 3 197 165 -1.4 0 -1.2 -1.4 04/17/2006 05:00:00 0.4 0.2 1.1 0.4 0.6 0.4 1.9 0.4 1.9 0.5 3 0.7 212 9 199 165 -1.4 0 -1.2 -1.4 04/17/2006 05:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 1.3 0.3 2.3 0.7 210 12 165 165 -1.4 0 -1.4 -1.7 04/17/2006 05:20:00 0.4 0 0.4 0.4 0.4 0.2 1.5 0.4 1.7 0.5 2.6 0.4 199 11 165 165 -1.4 0 -1.4 -1.4 04/17/2006 05:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0.2 1.1 0.4 248 21 165 165 -1.5 0 -1.2 -1.4 04/17/2006 05:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 1 0.5 2.3 0.4 213 15 165 165 -1.6 0 -1.4 -1.7 04/17/2006 05:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 1.5 0.5 2.6 0.4 202 7 165 165 -1.4 0 -1.2 -1.4 04/17/2006 06:00:00 0.4 0 0.4 0.4 0.8 0.6 1.9 0.4 2 0.5 3 0.7 194 9 165 165 -1.4 0 -1.2 -1.4 04/17/2006 06:10:00 0.4 0 0.4 0.4 1.4 0.2 1.9 0.7 2.5 0.2 3 1.9 184 3 165 165 -1.4 0 -1.2 -1.4 04/17/2006 06:20:00 0.4 0 0.4 0.4 1.3 0.2 1.9 0.7 2.4 0.2 2.6 1.9 181 2 165 165 -1.3 0.1 -0.8 -1.4 04/17/2006 06:30:00 0.7 0.5 1.9 0.4 1.4 0.6 2.6 0.4 2.4 0.5 3 1.1 177 3 172 165 -0.8 0 -0.5 -1 04/17/2006 06:40:00 0.4 0 0.4 0.4 0.4 0 0.7 0.4 0.6 0.3 1.5 0.4 184 3 165 165 -0.5 0.1 -0.3 -0.8 04/17/2006 06:50:00 1 0.6 2.3 0.4 1.4 0.9 3 0.4 2.3 0.6 3.4 1.1 175 4 170 165 -1 0 -0.8 -1.2 04/17/2006 07:00:00 1.9 0.4 2.6 0.7 2.3 0.6 3.4 0.7 2.9 0.4 3.8 1.9 170 5 164 165 -1 0 -1 -1.2 04/17/2006 07:10:00 0.5 0.3 1.5 0.4 0.5 0.3 1.5 0.4 1.7 0.2 2.3 1.1 180 8 165 165 -1.1 0 -0.8 -1.4 04/17/2006 07:20:00 1.3 0.6 2.3 0.4 2.1 0.5 3 0.4 2.8 0.4 3.4 1.5 182 3 177 165 -0.5 0.2 -0.1 -0.8 04/17/2006 07:30:00 1.2 0.2 1.5 0.7 1.8 0.2 2.3 1.1 2.8 0.2 3.4 2.3 189 2 190 165 -0.5 0 -0.3 -0.8 04/17/2006 07:40:00 1.7 0.3 2.3 0.7 2.2 0.3 2.6 1.5 3.2 0.3 3.8 2.6 190 3 187 165 -0.2 0 0.2 -0.5 04/17/2006 07:50:00 1.8 0.3 2.6 1.1 2.4 0.3 3.4 1.5 3.2 0.3 4.2 2.6 183 3 185 165 0.2 0 0.4 -0.1 04/17/2006 08:00:00 1.6 0.5 2.6 0.7 2 0.6 3 0.7 2.8 0.4 3.4 1.9 177 7 173 165 0.4 0 0.7 0.2 04/17/2006 08:10:00 1.2 0.5 2.3 0.4 1.6 0.6 3.4 0.4 2.6 0.4 3.4 1.9 171 9 168 165 0.8 0 0.9 0.7 04/17/2006 08:20:00 2.3 0.6 3.8 0.7 2.9 0.8 4.6 0.7 3.3 0.5 4.2 1.9 167 9 165 165 0.8 0 0.9 0.7 04/17/2006 08:30:00 2.2 0.5 3.4 1.1 2.7 0.6 4.6 1.5 3 0.4 4.2 1.9 174 8 169 165 0.9 0 1.1 0.9 04/17/2006 08:40:00 2.4 0.5 3.8 1.1 2.7 0.6 4.6 1.1 3.4 0.4 4.2 2.3 180 7 164 165 0.8 0 0.9 0.7 04/17/2006 08:50:00 1.9 0.5 3 0.7 2.2 0.6 3.8 0.7 2.9 0.4 3.8 1.9 180 7 164 165 1.1 0.1 1.4 0.7 04/17/2006 09:00:00 1.5 0.5 3 0.7 1.7 0.6 3.8 0.4 2.7 0.4 4.6 1.9 180 10 176 165 1.2 0 1.4 0.7 04/17/2006 09:10:00 1.9 0.7 3.4 0.7 2.4 1 4.6 0.4 2.9 0.6 4.2 1.5 162 8 156 165 1.3 0.1 1.6 0.9 04/17/2006 09:20:00 2.1 0.3 3 1.1 3 0.4 4.2 1.9 3.1 0.3 3.8 2.3 162 9 165 165 1.5 0.1 1.8 0.9 04/17/2006 09:30:00 2.3 0.6 3.8 1.1 2.7 1.1 4.6 0.4 3.2 0.4 4.6 1.9 156 8 164 165 1.5 0 1.8 0.9 04/17/2006 09:40:00 2.4 0.6 3.8 1.1 2.3 1.3 4.6 0.4 3.4 0.5 4.6 2.3 155 15 167 165 1.6 0 1.8 1.1 04/17/2006 09:50:00 2.8 0.5 4.2 1.9 3.3 0.5 4.6 2.3 3.7 0.3 4.6 3 163 12 157 165 1.5 0 1.6 1.4 04/17/2006 10:00:00 2.6 0.6 4.2 1.5 3.1 0.6 4.9 1.9 3.3 0.4 4.6 2.3 164 10 137 165 1.8 0 1.8 1.6 04/17/2006 10:10:00 2.2 0.4 3.4 1.1 2.8 0.4 3.8 1.9 3.4 0.5 4.6 2.3 156 10 160 165 1.6 0.2 1.8 1.4 04/17/2006 10:20:00 1.8 0.4 2.6 0.7 2.5 0.4 3.4 1.5 3 0.6 4.6 1.5 157 11 143 165 1.4 0.1 1.8 0.9 04/17/2006 10:30:00 1.8 0.7 3.8 0.7 2.6 0.7 4.6 1.5 2.9 0.9 5.3 0.7 156 12 148 165 2 0 2.3 1.6 04/17/2006 10:40:00 2.2 0.6 4.2 0.7 3.5 0.8 6.1 1.9 3.8 0.6 5.7 2.3 164 18 183 165 2.2 0 2.3 2.1 04/17/2006 10:50:00 1.8 0.6 3.4 0.4 2.8 0.9 4.6 0.4 3.4 1.1 5.7 0.4 172 10 171 165 2.3 0 2.8 2.1 04/17/2006 11:00:00 2 0.6 3.4 0.7 3.1 0.8 4.9 1.1 3.4 0.8 5.3 1.5 170 9 168 165 2.3 0 2.8 2.1 04/17/2006 11:10:00 2.2 0.6 3.4 0.7 3.2 0.7 4.9 1.5 3.9 0.9 5.7 2.3 171 9 162 165 2.3 0 2.6 2.3 04/17/2006 11:20:00 2 0.5 3.8 0.7 3 0.6 4.9 1.5 3.3 0.7 4.9 1.5 168 9 174 165 2.7 0 2.8 2.6 04/17/2006 11:30:00 2.4 0.7 3.8 1.1 3.2 0.6 4.6 1.9 3.7 0.8 5.3 1.1 168 9 169 165 2.9 0 3 2.6 04/17/2006 11:40:00 2.3 0.5 3.8 0.4 2.9 0.5 4.6 1.1 3.6 0.6 5.3 1.1 170 10 174 165 2.8 0 3 2.6 04/17/2006 11:50:00 2.3 0.4 3.4 1.5 3 0.4 4.2 2.3 3.7 0.6 5.3 2.3 174 11 164 165 2.8 0 2.8 2.6 04/17/2006 12:00:00 2.3 0.5 3.4 1.5 2.9 0.4 3.8 1.9 3.5 0.6 4.9 2.3 161 11 164 165 2.8 0.1 3 2.6 04/17/2006 12:10:00 2.7 0.5 3.8 1.1 3.7 0.6 5.3 1.9 4.9 1 6.8 2.3 150 9 164 165 3 0 3 2.8 04/17/2006 12:20:00 2.5 0.4 3.4 1.5 4.5 0.7 6.5 2.6 5.1 0.6 6.8 3.4 145 8 137 165 2.9 0 3 2.8 04/17/2006 12:30:00 2.3 0.3 3.4 1.5 4.7 0.6 6.8 3.4 4.8 0.6 6.5 3.4 146 8 151 165 2.9 0 3 2.6 04/17/2006 12:40:00 2 0.5 3 1.1 4.3 0.7 6.8 3 4.3 0.7 6.5 2.6 142 11 135 165 2.7 0.1 3 2.3 04/17/2006 12:50:00 1.9 0.4 3 1.1 4.1 0.6 5.7 3 4.1 0.5 5.7 3.4 149 9 141 165 2.4 0.2 3 2.1 04/17/2006 13:00:00 2.1 0.4 3.4 1.1 4.4 0.6 6.8 2.6 4.4 0.6 6.5 2.6 135 11 138 165 2.5 0.1 2.8 2.3 04/17/2006 13:10:00 2.6 0.4 3.4 1.5 5.2 0.6 6.8 3 5.3 0.6 6.5 3 144 8 154 165 2.7 0.2 3 2.3 04/17/2006 13:20:00 2.9 0.3 3.4 2.3 5.8 0.5 6.8 4.6 6 0.6 7.2 4.6 153 4 151 165 2.9 0.2 3.5 2.6 04/17/2006 13:30:00 2.8 0.3 3.8 1.9 5.6 0.6 7.6 4.6 5.7 0.6 7.2 4.6 148 6 157 165 2.9 0 3.3 2.6 04/17/2006 13:40:00 2.6 0.3 3.4 1.9 5.3 0.5 7.2 4.2 5.4 0.5 6.8 4.2 150 6 147 165 2.9 0.2 3.5 2.6 04/17/2006 13:50:00 2.8 0.2 3.4 2.3 5.8 0.5 7.2 4.6 5.9 0.5 6.8 4.6 147 6 155 165 3.3 0.2 3.8 2.8 04/17/2006 14:00:00 3.2 0.4 4.2 2.3 6.4 0.6 8.4 4.9 6.6 0.6 8.4 5.3 146 4 145 165 2.2 0.3 2.8 1.8 04/17/2006 14:10:00 3.5 0.4 4.6 2.3 7.3 0.8 9.5 5.3 7.3 0.8 9.9 5.3 137 5 136 165 1.5 0.2 1.8 0.9 04/17/2006 14:20:00 2.8 0.4 3.8 2.3 6.2 0.8 8 4.9 6.2 0.8 8 4.6 137 4 139 165 0.9 0.2 1.4 0.7 04/17/2006 14:30:00 3.1 0.4 4.2 2.3 6.6 0.6 8 4.9 6.7 0.7 9.5 4.9 149 6 157 165 0.4 0 0.7 0.2 04/17/2006 14:40:00 2.8 0.4 3.8 1.5 5.9 0.7 7.6 3.8 6.2 0.7 8 4.6 160 7 162 165 0 0.1 0.4 -0.5 04/17/2006 14:50:00 1.6 0.5 2.6 0.7 3.9 0.8 6.1 2.6 4.1 0.8 5.7 2.6 161 8 173 165 -0.2 0.1 -0.1 -0.5 04/17/2006 15:00:00 0.4 0.2 1.5 0.4 1.4 0.9 3.4 0.4 1.5 1 3.4 0.4 144 64 179 165 -0.2 0.1 0.2 -0.5 04/17/2006 15:10:00 0.4 0 0.4 0.4 2 0.5 3 0.4 2 0.6 3.4 0.4 317 12 165 165 1.4 0.7 2.3 -0.5 04/17/2006 15:20:00 0.4 0.3 2.6 0.4 1.9 0.8 3.4 0.4 1.9 0.8 3.4 0.4 349 43 118 165 1.8 0 2.3 1.6 04/17/2006 15:30:00 2.2 1.1 4.9 0.4 2 1.2 4.9 0.4 2 1.1 4.6 0.4 135 27 123 165 2.4 0.1 2.8 1.8 04/17/2006 15:40:00 3.7 0.4 4.6 2.6 3.5 0.4 4.6 2.3 3.7 0.4 4.6 2.6 140 9 133 165 1.9 0.1 2.6 1.6 04/17/2006 15:50:00 3.7 0.7 5.7 1.9 3.7 0.8 6.1 1.9 3.5 0.8 5.3 1.5 121 8 110 165 2 0 2.3 1.8 04/17/2006 16:00:00 4.2 0.6 6.1 1.9 4.2 0.7 6.1 1.5 4.1 0.6 5.3 2.3 124 7 123 165 2.5 0.3 3 1.8 04/17/2006 16:10:00 5 0.8 6.8 3 5 0.8 6.8 3 5 0.9 6.8 2.6 131 13 119 165 2.9 0.1 3.3 2.6 04/17/2006 16:20:00 5.6 0.4 6.8 4.6 5.6 0.5 6.8 4.2 5.6 0.5 6.8 3.8 139 6 147 165 3 0.1 3.3 2.6 04/17/2006 16:30:00 6.6 0.6 8 4.9 6.6 0.6 8 4.9 6.7 0.6 8 4.9 142 5 143 165 2.8 0 3 2.6 04/17/2006 16:40:00 6.8 0.4 8 5.7 6.8 0.4 8 5.7 6.7 0.5 8 4.9 135 5 135 165 2.7 0 3 2.6 04/17/2006 16:50:00 6.8 0.5 8.4 4.6 6.8 0.6 8.8 4.9 6.8 0.5 8.4 5.7 136 5 119 165 2.4 0.1 2.8 2.3 04/17/2006 17:00:00 7.5 0.4 8.8 6.5 7.4 0.4 8.4 6.1 7.5 0.5 8.8 6.1 141 6 137 165 1.8 0.2 2.6 1.4 04/17/2006 17:10:00 7.5 0.4 8.4 6.1 7.4 0.4 8.4 5.7 7.5 0.5 8.8 5.7 145 4 145 165 1.4 0 1.6 1.1 04/17/2006 17:20:00 7.3 0.5 8.4 5.7 7.3 0.4 8 5.7 7.4 0.6 8.4 4.9 145 4 145 165 1.5 0 1.8 1.1 04/17/2006 17:30:00 7.5 0.4 8.4 6.1 7.5 0.4 8.4 6.1 7.6 0.5 8.4 6.1 142 3 139 165 1.9 0.2 2.3 1.4 04/17/2006 17:40:00 7.4 0.6 8.8 6.1 7.4 0.5 8.8 6.1 7.3 0.6 8.4 5.3 142 5 141 165 1.5 0.2 2.1 0.9 04/17/2006 17:50:00 7.2 0.5 8.4 5.3 7.3 0.5 8 5.7 7.1 0.7 8.4 5.3 137 5 135 165 1.3 0.1 1.4 0.9 04/17/2006 18:00:00 6.2 0.8 8 4.6 6.1 0.9 8.4 4.2 6.2 0.8 8 4.6 154 11 139 165 1.1 0 1.6 0.7 04/17/2006 18:10:00 4.8 1.2 6.8 1.9 4.8 1.3 6.8 1.5 4.9 1.1 6.8 1.9 157 18 133 165 1.4 0.2 2.1 0.9 04/17/2006 18:20:00 3.5 0.6 4.9 1.9 3.4 0.6 4.9 1.5 3.7 0.6 5.3 2.3 161 17 192 165 1.8 0.1 2.1 1.6 04/17/2006 18:30:00 4.1 0.8 6.1 2.3 4.1 0.8 5.7 2.3 4.2 1 6.1 2.3 140 11 153 165 1.9 0 2.3 1.6 04/17/2006 18:40:00 4.7 0.7 6.5 3.4 4.6 0.7 6.5 3 4.7 0.6 6.5 3 141 8 145 165 1.4 0.2 1.8 0.9 04/17/2006 18:50:00 3.9 0.4 4.9 2.6 3.8 0.4 4.9 2.6 3.9 0.4 4.9 2.6 146 8 131 165 1.4 0 1.8 1.1 04/17/2006 19:00:00 3.7 0.5 4.9 2.3 3.8 0.5 4.9 2.6 3.7 0.5 4.9 2.6 151 13 159 165 1.8 0 1.8 1.4 04/17/2006 19:10:00 4.1 0.4 4.9 3 4.2 0.4 4.9 2.6 4.1 0.5 4.9 2.6 130 9 122 165 1.6 0.2 1.8 0.9 04/17/2006 19:20:00 4.1 0.4 4.9 3 4.2 0.4 5.3 3 4 0.4 4.9 3 123 5 89 165 0.8 0.1 1.4 0.7 04/17/2006 19:30:00 3.2 0.4 4.2 2.3 3.3 0.4 4.2 2.3 3.1 0.4 4.2 2.3 121 6 120 165 0.5 0 0.7 0.2 04/17/2006 19:40:00 3.4 0.3 4.2 2.3 3.5 0.4 4.6 2.6 3.4 0.4 4.2 2.3 122 6 121 165 0.4 0 0.7 0.2 04/17/2006 19:50:00 3.7 0.4 4.6 2.6 3.8 0.5 4.9 2.6 3.7 0.4 4.9 3 116 4 113 165 0.3 0 0.7 0.2 04/17/2006 20:00:00 4.3 0.3 4.9 3.4 4.4 0.3 4.9 3.4 4.3 0.4 5.3 3.4 120 6 114 165 0.2 0 0.4 0.2 04/17/2006 20:10:00 4.3 0.3 4.9 3.4 4.4 0.3 5.3 3.4 4.3 0.3 4.9 3.4 123 3 124 165 0.2 0 0.4 0.2 04/17/2006 20:20:00 4.4 0.3 4.9 3.8 4.5 0.3 5.3 3.8 4.4 0.4 5.3 2.6 127 5 126 165 0.3 0 0.4 0.2 04/17/2006 20:30:00 4.7 0.3 5.3 3.8 4.8 0.2 5.3 4.2 4.6 0.4 5.3 3 118 3 118 165 0.4 0 0.7 0.2 04/17/2006 20:40:00 4.6 0.3 5.3 4.2 4.7 0.3 5.3 4.2 4.5 0.4 5.3 3 121 2 118 165 0.3 0 0.7 0.2 04/17/2006 20:50:00 4.5 0.2 4.9 3.8 4.6 0.2 4.9 3.8 4.5 0.2 4.9 3.4 118 2 119 165 0.4 0 0.7 0.2 04/17/2006 21:00:00 4.3 0.2 4.9 3.8 4.4 0.2 4.9 3.8 4.3 0.2 4.9 3.4 114 2 114 165 0.4 0 0.7 0.2 04/17/2006 21:10:00 4.2 0.3 4.9 3.4 4.3 0.3 4.9 3.8 4.2 0.3 4.9 3 113 2 113 165 0.3 0 0.7 0.2 04/17/2006 21:20:00 3.9 0.2 4.2 3.4 4 0.2 4.6 3.4 3.9 0.2 4.6 3 108 6 116 165 0.3 0 0.7 0.2 04/17/2006 21:30:00 3.7 0.2 4.2 3 3.8 0.2 4.2 3 3.8 0.3 4.2 3 83 8 96 165 0.3 0.1 0.7 0.2 04/17/2006 21:40:00 3.6 0.3 4.2 2.6 3.6 0.4 4.2 2.3 3.5 0.3 4.2 2.3 58 8 63 165 0.3 0 0.4 0.2 04/17/2006 21:50:00 2.5 0.3 3 1.9 2.4 0.3 3 1.5 2.5 0.4 3 1.5 45 13 32 165 0.3 0 0.7 0.2 04/17/2006 22:00:00 2.2 0.4 3.4 1.5 2.2 0.4 3.4 1.1 2.2 0.3 3 1.5 70 17 62 165 0.5 0 0.7 0.2 04/17/2006 22:10:00 2 1 4.6 0.4 2 1 4.6 0.4 2.2 1 4.6 0.4 127 18 119 165 0.2 0.1 0.7 0.2 04/17/2006 22:20:00 2.6 0.7 3.8 1.1 2.6 0.8 4.2 1.1 2.5 0.7 4.2 1.1 79 9 75 165 0.3 0.1 0.7 -0.1 04/17/2006 22:30:00 3.2 0.5 4.6 1.9 3.3 0.5 4.9 1.9 3.2 0.5 4.6 2.3 89 6 96 165 0.7 0 0.9 0.7 04/17/2006 22:40:00 2.6 0.4 3.4 1.9 2.8 0.4 3.4 1.9 2.9 0.3 3.8 1.9 86 9 83 165 0.5 0 0.7 0.4 04/17/2006 22:50:00 1.9 0.3 2.6 1.1 1.9 0.3 2.6 1.1 2.2 0.3 3 1.5 87 8 87 165 0.7 0 0.9 0.7 04/17/2006 23:00:00 2 0.6 3.4 0.7 2 0.7 3.4 0.7 2.3 0.6 3.4 1.1 87 17 80 165 0.8 0 0.9 0.7 04/17/2006 23:10:00 1.7 0.5 3 0.7 1.6 0.6 3 0.4 2 0.4 3 1.1 66 11 73 165 0.7 0 0.9 0.7 04/17/2006 23:20:00 2.3 0.6 4.2 1.5 2.2 0.7 4.2 1.1 2.4 0.5 3.8 1.1 45 18 78 165 0.7 0 0.9 0.7 04/17/2006 23:30:00 3.4 0.5 4.9 2.6 3.4 0.5 4.9 2.6 3.3 0.5 4.6 2.3 33 4 33 165 0.5 0 0.7 0.4 04/17/2006 23:40:00 5.2 0.6 6.8 3.4 5.1 0.6 6.5 3.4 5.1 0.6 6.5 3.4 24 5 18 165 0.5 0 0.7 0.2 04/17/2006 23:50:00 5.2 0.8 7.2 3.4 5.1 1.1 7.6 2.6 5.1 0.9 7.6 3 52 26 81 165 0.5 0 0.9 0.2 04/18/2006 00:00:00 7.1 1.1 9.9 4.9 7.2 1.1 9.9 4.9 6.9 1.1 9.9 4.2 105 12 102 165 0.8 0 0.9 0.7 04/18/2006 00:10:00 6 1 8.8 3.8 6.1 1 8.8 4.2 5.9 1.1 8.8 3.8 125 7 125 165 0.6 0 0.7 0.7 04/18/2006 00:20:00 5 1 7.6 2.3 5.1 1 7.6 2.3 5.1 0.9 6.8 2.6 110 23 130 165 0.5 0 0.7 0.4 04/18/2006 00:30:00 4.1 0.8 6.5 2.3 4.1 0.9 6.8 2.3 4.1 0.7 6.1 2.3 57 21 89 165 0.3 0.1 0.7 0.2 04/18/2006 00:40:00 4.6 0.5 5.7 2.6 4.4 0.6 5.7 2.6 4.8 0.5 5.7 3.4 23 6 29 165 0.1 0 0.2 -0.1 04/18/2006 00:50:00 4.1 0.5 5.7 2.6 4 0.6 5.7 1.9 4.2 0.5 5.7 3 28 7 33 165 -0.1 0 0.2 -0.1 04/18/2006 01:00:00 5.3 0.4 6.5 4.2 5.3 0.5 6.8 4.2 4.9 0.5 6.5 3.4 43 4 42 165 -0.2 0 0.2 -0.3 04/18/2006 01:10:00 4.3 0.6 5.7 3.4 4.3 0.6 6.1 3.4 4.2 0.5 5.7 3.4 37 7 44 165 0 0 0.2 -0.1 04/18/2006 01:20:00 3.7 0.2 4.2 3 3.7 0.3 4.2 3 3.7 0.3 4.6 3 39 3 43 165 0.1 0 0.2 -0.3 04/18/2006 01:30:00 3.6 0.3 4.6 3 3.5 0.3 4.2 2.6 3.7 0.2 4.6 3 30 3 46 165 0.2 0 0.2 0.2 04/18/2006 01:40:00 4.1 0.3 4.9 3 4.1 0.4 5.3 3 4.2 0.4 4.9 3.4 31 5 33 165 0.2 0 0.4 0.2 04/18/2006 01:50:00 4.1 0.3 4.9 3 4 0.4 4.9 3 4.2 0.4 4.9 3 26 4 34 165 0.2 0 0.4 -0.1 04/18/2006 02:00:00 4.5 0.3 5.3 3.8 4.2 0.4 5.3 3.4 4.6 0.3 5.3 4.2 23 3 25 165 0.1 0 0.2 -0.1 04/18/2006 02:10:00 5.6 0.7 7.2 3.8 5.4 0.8 7.2 2.3 5.6 0.8 7.6 3.8 23 5 23 165 0.2 0 0.2 -0.1 04/18/2006 02:20:00 5.6 1 8 3.8 5.5 1 8 3.4 5.4 0.9 8 3.4 39 7 36 165 0.1 0 0.2 -0.1 04/18/2006 02:30:00 6.1 0.9 8.8 3.8 6.1 1 9.1 3.4 6 0.9 8.8 3.4 39 8 51 165 0.2 0 0.2 -0.1 04/18/2006 02:40:00 4.9 0.7 6.5 3 4.2 1 6.1 1.9 4.7 0.7 6.5 2.6 18 7 23 165 0.2 0 0.2 0.2 04/18/2006 02:50:00 4.3 0.5 5.7 3 4.1 0.6 5.7 2.3 4.1 0.6 6.1 2.6 36 11 25 165 0.2 0 0.4 0.2 04/18/2006 03:00:00 3.9 0.5 5.3 2.6 3.5 0.9 5.3 1.1 3.8 0.5 4.9 2.6 30 15 26 165 0.2 0 0.4 0.2 04/18/2006 03:10:00 4.2 0.5 5.3 3 3.3 0.8 4.9 1.5 4.2 0.5 5.7 3 16 7 10 165 0.3 0 0.4 0.2 04/18/2006 03:20:00 5.2 0.6 6.1 3.8 4 0.8 5.7 1.9 5 0.5 6.1 3.4 13 5 34 165 0.4 0 0.7 0.2 04/18/2006 03:30:00 3.9 0.7 5.7 2.3 3 0.6 4.6 1.5 3.5 0.7 5.3 2.3 16 9 9 165 0.3 0 0.7 0.2 04/18/2006 03:40:00 4.2 1.2 7.2 1.5 3.5 1.2 6.8 1.1 4 1.1 7.2 1.5 19 12 12 165 0.3 0 0.4 0.2 04/18/2006 03:50:00 5.3 0.8 7.6 3.8 3.1 1 5.7 1.5 5.1 0.8 7.2 3.4 6 6 357 165 0.2 0 0.4 0.2 04/18/2006 04:00:00 5.1 0.6 6.5 3 3.5 1.2 5.7 1.5 4.7 0.6 6.5 3.4 10 9 9 165 0.2 0 0.4 0.2 04/18/2006 04:10:00 4.7 0.7 6.5 3 2.8 1 5.3 1.1 4.4 0.6 6.5 3 4 9 358 165 0.2 0 0.4 0.2 04/18/2006 04:20:00 5.1 0.6 6.5 3 3.6 1 6.1 1.5 5 0.7 6.5 3.4 11 6 15 165 0.2 0 0.4 -0.1 04/18/2006 04:30:00 4.9 0.4 5.7 3.8 3.7 0.9 5.7 1.1 4.9 0.4 6.1 3.8 14 6 10 165 0.2 0 0.4 0.2 04/18/2006 04:40:00 4.4 0.4 5.3 3.4 3.7 0.9 4.9 1.1 4.4 0.4 5.3 2.3 1 17 25 165 0.3 0 0.7 0.2 04/18/2006 04:50:00 4.7 0.5 6.1 3 4.2 0.8 5.7 1.9 4.6 0.5 5.7 3 346 6 354 165 0.2 0 0.2 0.2 04/18/2006 05:00:00 4.9 0.8 7.2 3 3.6 1.1 6.1 1.1 4.8 0.8 6.8 3 353 5 356 165 0.1 0 0.2 -0.1 04/18/2006 05:10:00 5.8 0.8 8.4 4.2 4.2 1 6.8 2.3 5.6 0.8 8 3.8 354 8 342 165 0.2 0 0.4 0.2 04/18/2006 05:20:00 7.2 0.6 8.8 5.3 4.5 1 8 2.6 7.1 0.6 8.8 5.7 8 5 16 165 0.4 0 0.7 0.2 04/18/2006 05:30:00 6.5 1.1 8.8 4.2 4.3 1.2 7.2 1.9 6.3 1.1 8.8 3.8 1 8 4 165 0.5 0 0.7 0.2 04/18/2006 05:40:00 5.5 1.9 8.8 1.9 4.5 1.5 8.4 1.5 5.3 1.9 8.8 2.3 20 12 18 165 0.5 0 0.7 0.4 04/18/2006 05:50:00 4.8 1 6.8 2.6 4.6 1.1 7.2 2.3 4.6 1 7.2 2.3 39 13 62 165 0.5 0 0.7 0.4 04/18/2006 06:00:00 5.5 0.8 7.6 3.8 5.4 0.8 7.2 3.4 5.5 0.7 7.6 3.8 36 7 38 165 0.6 0 0.7 0.4 04/18/2006 06:10:00 5 0.6 6.5 3.4 4.9 0.7 6.5 3 5 0.7 6.8 3 36 5 35 165 0.6 0 0.7 0.4 04/18/2006 06:20:00 4.3 0.5 6.1 3.4 4.2 0.5 5.7 3 4.3 0.6 5.7 3 34 4 32 165 0.6 0 0.9 0.4 04/18/2006 06:30:00 3.7 0.8 4.9 1.9 3.5 0.9 4.9 1.5 3.9 0.8 5.3 2.3 32 6 30 165 0.7 0 0.9 0.7 04/18/2006 06:40:00 3.8 0.7 5.3 2.3 3.6 0.7 5.3 1.9 3.9 0.7 5.7 2.3 40 10 44 165 0.8 0 0.9 0.7 04/18/2006 06:50:00 3.7 0.8 5.7 1.9 3.4 0.8 5.3 1.5 3.5 0.8 5.7 2.3 25 7 20 165 0.8 0 0.9 0.7 04/18/2006 07:00:00 3.1 1 5.3 1.5 2.8 1 4.9 1.1 3.2 1 5.3 1.5 28 9 25 165 0.8 0 0.9 0.7 04/18/2006 07:10:00 3.6 1 5.3 1.9 2.9 0.8 4.6 1.1 3.6 1 5.7 1.5 13 23 12 165 0.9 0 1.1 0.7 04/18/2006 07:20:00 3.2 0.8 4.9 1.5 2.9 0.8 4.9 1.1 3.3 0.8 4.9 1.5 34 17 25 165 1 0 1.1 0.9 04/18/2006 07:30:00 4.5 0.6 6.1 2.6 3.8 0.8 5.3 1.5 4.5 0.7 6.1 3 19 8 10 165 1.2 0.1 1.6 0.9 04/18/2006 07:40:00 3.7 0.6 4.9 2.3 3.5 0.7 4.9 1.5 3.8 0.6 5.3 2.3 31 7 19 165 1.5 0 1.6 1.4 04/18/2006 07:50:00 3.9 0.6 5.7 2.6 3.8 0.6 5.3 2.6 3.9 0.6 5.7 2.6 43 12 37 165 1.5 0 1.8 1.4 04/18/2006 08:00:00 4.8 0.7 6.5 3 4.8 0.8 6.5 3 4.8 0.8 6.5 3 46 9 48 165 1.7 0.2 2.3 1.4 04/18/2006 08:10:00 4.7 0.8 6.5 3 4.6 0.9 6.5 2.6 4.8 0.8 6.8 3 29 10 18 165 2.4 0.2 2.8 2.1 04/18/2006 08:20:00 4.5 0.7 6.1 2.6 4.3 0.8 5.7 2.3 4.5 0.7 6.1 3 25 8 34 165 2.3 0 2.6 1.8 04/18/2006 08:30:00 5 0.6 6.5 3.4 4.5 0.8 6.5 1.9 4.9 0.7 6.5 3.4 20 8 29 165 2.4 0.1 2.8 2.1 04/18/2006 08:40:00 5.2 0.7 6.8 3.4 4.9 0.9 6.8 2.6 5 0.9 6.8 2.6 25 7 23 165 1.9 0.2 2.3 1.4 04/18/2006 08:50:00 5.2 0.6 6.5 3.4 4.8 0.7 6.5 3 4.9 0.6 6.5 3 28 9 16 165 1.8 0.1 2.1 1.6 04/18/2006 09:00:00 5.7 0.7 7.6 3.8 5.3 0.8 7.2 1.9 5.6 0.7 7.2 3.4 27 9 16 165 1.8 0 1.8 1.8 04/18/2006 09:10:00 5.7 0.6 7.6 4.2 3.7 1.1 6.5 1.9 5.6 0.6 7.2 3.8 8 6 11 165 1.8 0 1.8 1.6 04/18/2006 09:20:00 5.8 0.7 7.6 3.8 3.3 0.9 6.5 1.5 5.7 0.6 7.2 4.6 3 7 357 165 2.2 0.3 2.8 1.8 04/18/2006 09:30:00 6.3 0.7 8 4.6 4.9 1.5 7.6 1.9 6.3 0.8 8.4 4.2 11 8 19 165 2.5 0.2 2.8 2.1 04/18/2006 09:40:00 6.1 1 8.4 3.4 4.9 1.5 8 1.5 6.1 1 8.4 3.4 11 9 16 165 2.3 0 2.6 2.3 04/18/2006 09:50:00 6.7 1 9.5 4.9 5.3 1.9 9.5 1.9 6.8 1.1 9.9 4.9 11 8 21 165 2 0.2 2.6 1.6 04/18/2006 10:00:00 6.1 0.7 7.6 4.2 4.6 1.1 7.6 2.3 6 0.7 7.6 3.8 4 10 358 165 2.4 0.6 3.5 1.6 04/18/2006 10:10:00 5.3 0.7 7.2 3 4.1 1 7.2 2.3 5.3 0.8 7.2 2.3 7 11 0 165 3.1 0.1 3.5 2.8 04/18/2006 10:20:00 5.3 0.6 6.5 3.4 4.5 1 6.5 2.3 5.4 0.7 7.2 3.4 14 9 8 165 3 0.1 3.5 2.8 04/18/2006 10:30:00 5.2 0.6 6.5 3.4 4.9 0.6 6.1 3 5.1 0.7 7.2 3.4 24 8 7 165 2.3 0.3 3 1.8 04/18/2006 10:40:00 5.7 0.8 7.2 3.8 5.4 0.9 7.2 2.6 5.3 0.8 7.2 3.8 36 13 34 165 1.3 0.4 1.8 0.9 04/18/2006 10:50:00 4.4 1.3 7.6 2.3 3.9 1.5 7.6 1.5 4.1 1.2 7.6 1.9 6 19 26 165 1 0 1.4 0.9 04/18/2006 11:00:00 3.4 0.4 4.6 1.9 3.3 0.5 4.6 1.5 3.3 0.4 4.2 2.6 342 8 344 165 3 1 4.5 1.4 04/18/2006 11:10:00 3.7 0.7 5.3 2.3 3.3 0.8 4.9 1.1 3.8 0.7 5.3 1.9 351 13 356 165 4.3 0.5 5 3.3 04/18/2006 11:20:00 3.7 0.6 4.9 2.3 2.9 0.8 4.6 0.7 3.4 0.6 4.9 2.3 12 11 10 165 3.5 0.9 5.2 2.3 04/18/2006 11:30:00 4.1 0.6 5.7 2.6 3.6 0.8 5.7 1.5 4.2 0.7 5.7 2.3 18 11 27 165 4.9 0.1 5.5 4.5 04/18/2006 11:40:00 4.5 0.6 6.5 2.3 4.2 0.7 6.5 1.9 4.5 0.6 6.8 2.6 22 9 36 165 4.3 0.4 5 3.5 04/18/2006 11:50:00 4.9 0.6 6.1 3.4 4.4 0.9 6.1 2.3 4.9 0.6 6.8 3.4 17 10 29 165 3.6 0.1 4 3 04/18/2006 12:00:00 5.2 0.8 7.2 3 4.7 1.1 7.2 2.3 5.1 0.8 7.2 3 21 14 16 165 3.5 0.5 4.3 2.8 04/18/2006 12:10:00 4.8 0.6 6.5 3 4.6 0.7 6.1 2.3 4.7 0.6 6.1 3.4 25 9 29 165 3.3 0.3 4 2.3 04/18/2006 12:20:00 5.3 0.7 6.8 3.4 5.2 0.8 6.8 3 5.2 0.8 6.8 2.6 30 8 23 165 3 0.2 3.5 2.6 04/18/2006 12:30:00 5.3 0.8 7.6 3.4 5.2 0.8 8 2.6 5.2 0.7 7.6 3.8 27 8 29 165 2.7 0.2 3.3 2.3 04/18/2006 12:40:00 6.4 0.7 8.4 4.2 6.1 0.9 8 3.4 6.2 0.8 7.6 4.2 25 10 43 165 2.3 0 2.6 1.8 04/18/2006 12:50:00 6.3 0.8 8 4.2 5.8 1.1 7.6 2.6 6.1 0.8 8 4.2 19 9 23 165 2.4 0 2.6 2.3 04/18/2006 13:00:00 6 0.6 7.2 4.6 5.9 0.6 7.6 3.8 5.9 0.6 7.6 4.2 26 6 30 165 2.4 0 2.8 2.3 04/18/2006 13:10:00 6 0.8 8 4.2 5.8 0.8 8.4 3.8 5.9 0.9 8 3.8 24 8 31 165 3.3 0.4 4 2.6 04/18/2006 13:20:00 6.4 0.6 7.6 4.9 6.3 0.6 7.6 4.6 6.3 0.6 7.6 4.6 28 6 19 165 3.5 0.1 3.8 2.8 04/18/2006 13:30:00 5.7 0.7 7.2 3.8 5.6 0.8 7.2 3.8 5.7 0.7 7.2 3.8 25 6 16 165 3.2 0.2 3.5 2.6 04/18/2006 13:40:00 5.9 0.6 7.2 3.8 5.8 0.7 7.2 3.8 5.9 0.7 7.2 3.4 33 6 34 165 2.9 0.2 3.3 2.3 04/18/2006 13:50:00 5.1 0.8 6.8 3.4 5 0.9 6.8 2.6 5.2 0.8 7.2 3.4 30 10 19 165 2.3 0.2 2.6 1.8 04/18/2006 14:00:00 5.7 0.6 6.8 3.8 5.6 0.6 6.8 3.8 5.6 0.7 6.8 4.2 33 6 34 165 2.1 0 2.3 1.8 04/18/2006 14:10:00 6 0.9 7.6 3.4 5.9 1 8 3.4 5.8 1 8 3.8 31 7 35 165 2.3 0 2.3 1.8 04/18/2006 14:20:00 5.7 0.9 7.6 3.4 5.6 0.9 7.2 3 5.7 0.9 7.6 3.4 32 7 32 165 2.4 0.1 2.8 1.8 04/18/2006 14:30:00 4.8 0.7 6.8 2.6 4.7 0.8 6.5 2.6 4.7 0.8 6.1 3 26 10 23 165 2.7 0.1 3 2.3 04/18/2006 14:40:00 5.1 0.5 6.5 3.8 4.9 0.6 6.1 2.6 5.1 0.6 6.8 2.6 25 11 18 165 2.7 0.1 3 2.3 04/18/2006 14:50:00 5 0.7 6.5 3 4.8 0.7 6.5 3 5 0.8 6.8 3.4 26 8 22 165 3.3 0.3 3.8 2.3 04/18/2006 15:00:00 4.9 0.6 6.5 3.4 4.7 0.6 6.5 3 4.8 0.6 6.5 3.4 24 8 31 165 3.4 0.3 4 2.8 04/18/2006 15:10:00 5.1 0.7 7.2 3.4 4.9 0.8 7.2 2.3 5.1 0.8 7.2 2.6 23 8 23 165 4 0 4.3 3.5 04/18/2006 15:20:00 5.3 0.6 6.8 3.8 5.1 0.7 6.8 3.4 5.4 0.6 6.8 3.8 23 7 29 165 4 0 4.3 3.8 04/18/2006 15:30:00 5.2 0.6 6.8 3 5.1 0.6 6.5 3 5.1 0.7 6.5 3.4 24 7 11 165 4 0 4.3 3.8 04/18/2006 15:40:00 5.1 0.5 6.8 3.8 5 0.6 6.8 3.8 5 0.6 6.8 3.4 30 8 29 165 3.8 0 4.3 3.3 04/18/2006 15:50:00 4.8 0.6 6.5 2.6 4.6 0.6 6.5 2.6 4.7 0.6 6.5 2.6 24 8 35 165 4.1 0.2 4.5 3.3 04/18/2006 16:00:00 4.6 0.7 6.1 3 4.3 0.7 5.7 2.3 4.6 0.7 6.5 2.6 23 9 25 165 4.2 0.1 4.5 3.8 04/18/2006 16:10:00 4.5 0.5 5.7 3 4.4 0.6 5.7 3 4.3 0.6 5.7 2.6 30 13 33 165 4 0.2 4.5 3.3 04/18/2006 16:20:00 4.7 0.6 6.1 3 4.7 0.6 6.1 3 4.7 0.7 6.5 2.6 37 10 28 165 3.5 0.3 4.3 3 04/18/2006 16:30:00 4.8 0.8 6.5 3 4.7 0.9 6.5 2.6 4.6 0.9 6.5 2.6 31 10 33 165 3.7 0.3 4.3 2.8 04/18/2006 16:40:00 5 0.7 6.5 3 4.8 0.7 6.5 2.6 4.8 0.8 6.8 2.6 28 10 31 165 4 0.3 4.5 3 04/18/2006 16:50:00 5.8 0.7 7.2 4.2 5.6 0.7 7.2 3.4 5.7 0.7 7.6 3.8 22 6 21 165 3.5 0.6 4.5 2.6 04/18/2006 17:00:00 5.5 0.5 6.8 3.8 5.3 0.6 6.5 3.8 5.4 0.5 6.5 4.2 21 6 15 165 2.7 0.2 3.3 2.6 04/18/2006 17:10:00 4.4 0.5 5.7 3 4 0.7 5.7 1.9 4.4 0.5 5.7 3 17 6 19 165 3.3 0.2 3.8 2.8 04/18/2006 17:20:00 4 0.5 4.9 2.6 3.6 0.6 4.9 1.9 3.9 0.5 4.9 3 16 9 18 165 2.9 0 3.3 2.6 04/18/2006 17:30:00 4.6 0.7 6.5 1.5 3.9 1 6.1 1.1 4.5 0.7 6.1 2.3 19 16 15 165 2.6 0.1 2.8 2.6 04/18/2006 17:40:00 4.5 0.5 5.7 3 3.5 0.9 5.7 1.9 4.5 0.5 5.7 3.4 10 6 9 165 2.5 0 2.8 2.6 04/18/2006 17:50:00 3.6 0.6 5.3 1.9 2.7 0.8 4.9 1.1 3.5 0.7 5.3 1.9 5 11 15 165 2.5 0 2.8 2.6 04/18/2006 18:00:00 2.6 0.7 3.8 1.1 2.2 0.6 3.8 0.7 2.3 0.6 3.4 0.7 347 8 357 165 2.4 0.1 2.6 1.8 04/18/2006 18:10:00 2.8 0.6 4.2 1.1 2.9 0.7 4.6 1.1 2.4 0.6 4.2 1.1 302 19 278 165 2.9 0.4 3.8 1.8 04/18/2006 18:20:00 4.9 1.4 8 2.3 4.9 1.5 8 2.6 4.7 1.6 8 2.3 332 15 346 165 4.1 0.2 4.5 3.5 04/18/2006 18:30:00 6.7 0.8 8.4 4.2 5.2 1.3 8 2.3 6.6 0.9 8 3.8 4 9 354 165 3.1 0.8 4.5 1.4 04/18/2006 18:40:00 6.9 0.7 8.8 5.3 5.7 1.2 8.4 3 6.6 0.7 8 4.9 10 9 8 165 1.4 0.2 1.8 1.4 04/18/2006 18:50:00 5.1 0.8 6.8 3.8 5.1 0.8 7.2 3.4 4.8 0.8 6.5 3.4 339 8 342 165 1.2 0 1.4 1.1 04/18/2006 19:00:00 4.6 0.5 5.7 3.4 4.6 0.6 6.1 3 4.5 0.5 5.7 3.4 341 6 337 165 1.3 0 1.4 0.9 04/18/2006 19:10:00 4.8 0.6 6.8 3 4.6 0.8 6.8 2.6 4.6 0.7 6.5 3 345 8 338 165 1.4 0 1.6 1.4 04/18/2006 19:20:00 5.1 0.6 6.8 3.8 5.1 0.6 6.8 4.2 4.9 0.6 6.5 3.8 332 8 334 165 1.4 0 1.6 1.4 04/18/2006 19:30:00 5.8 0.5 7.2 4.6 5.7 0.5 6.8 4.6 5.6 0.5 7.2 4.6 333 6 334 165 1.4 0 1.6 1.4 04/18/2006 19:40:00 5.2 0.7 6.8 3.8 5 0.7 7.2 3 4.9 0.6 6.5 3.8 329 9 326 165 1.5 0 1.8 1.1 04/18/2006 19:50:00 4.5 0.5 6.1 3 4 0.9 6.1 1.9 4.5 0.5 5.7 3.4 349 8 348 165 1.5 0.1 1.6 1.4 04/18/2006 20:00:00 3.7 0.4 4.9 2.3 3.7 0.5 4.6 1.9 3.7 0.4 4.9 2.3 338 6 328 165 1.2 0 1.4 1.1 04/18/2006 20:10:00 2.4 0.5 3.4 1.5 1.8 0.7 3.4 0.4 2.5 0.4 3.8 1.5 351 9 343 165 1.2 0 1.4 1.1 04/18/2006 20:20:00 2.4 0.8 4.6 0.7 1.5 0.9 4.6 0.4 2.3 0.7 4.6 0.7 1 10 20 165 1.2 0 1.4 1.1 04/18/2006 20:30:00 4.5 0.5 6.1 3.4 3.5 0.7 5.3 1.5 4.4 0.6 5.7 3 11 7 11 165 1.2 0 1.4 0.9 04/18/2006 20:40:00 5 0.4 6.1 3.8 3.9 0.8 5.7 1.9 5 0.5 6.1 3.4 353 10 3 165 1.1 0 1.4 0.9 04/18/2006 20:50:00 5.1 1.1 7.6 3 4.9 1.3 7.6 1.5 4.8 1 7.2 2.6 341 8 343 165 0.9 0 1.1 0.9 04/18/2006 21:00:00 5.1 0.9 7.6 3.4 5 0.9 7.2 3 4.8 0.9 7.2 3 330 9 349 165 0.8 0 0.9 0.9 04/18/2006 21:10:00 4.1 0.4 5.3 3 4 0.4 5.3 3 3.8 0.4 4.9 2.6 322 9 312 165 0.8 0 0.9 0.9 04/18/2006 21:20:00 3.1 0.5 4.6 1.5 3 0.6 4.6 1.1 3 0.4 3.8 1.9 321 11 331 165 0.8 0 0.9 0.7 04/18/2006 21:30:00 3.8 0.4 4.9 3 3.7 0.4 4.9 2.3 3.5 0.4 4.6 2.3 334 7 346 165 0.7 0 0.9 0.7 04/18/2006 21:40:00 4.4 0.6 6.1 3 4.4 0.6 6.1 3 4.2 0.6 5.7 3 334 8 334 165 0.6 0 0.9 0.4 04/18/2006 21:50:00 5.6 0.8 7.2 4.2 5.6 0.9 7.6 3 5.3 0.7 7.2 4.2 339 8 336 165 0.5 0 0.7 0.2 04/18/2006 22:00:00 5.6 0.7 7.6 3.8 5.6 0.8 8 3.4 5.4 0.7 7.2 3.8 343 7 351 165 0.5 0 0.7 0.2 04/18/2006 22:10:00 4.8 0.5 6.1 3.4 3.8 0.9 5.7 1.9 4.8 0.4 5.7 3.8 354 8 7 165 0.4 0.1 0.7 0.2 04/18/2006 22:20:00 4.9 0.7 6.8 3.4 4.9 0.6 6.8 3.4 4.8 0.6 6.5 3.8 337 8 332 165 0.3 0 0.7 0.2 04/18/2006 22:30:00 4.5 0.6 6.1 3.4 4.4 0.6 6.1 2.6 4.4 0.5 5.7 3.4 342 7 349 165 0.2 0 0.7 -0.1 04/18/2006 22:40:00 5.2 0.7 7.2 3.8 5.1 0.7 7.2 3.4 5 0.6 6.8 3.4 331 8 323 165 0.3 0.1 0.7 -0.1 04/18/2006 22:50:00 6.4 0.6 7.6 4.9 6.4 0.6 7.6 4.9 6.1 0.6 7.6 4.2 340 7 340 165 0.3 0 0.4 0.2 04/18/2006 23:00:00 6.4 0.7 8.4 4.6 6.4 0.9 9.1 3.8 6.2 0.8 8.4 4.2 342 6 344 165 0.4 0 0.7 0.2 04/18/2006 23:10:00 6.1 0.9 8.4 4.2 6.1 1 8.4 3.4 6 0.8 8 4.2 332 9 325 165 0.5 0 0.9 0.2 04/18/2006 23:20:00 5.6 0.7 7.6 4.2 5.5 0.7 7.6 3.8 5.5 0.8 7.6 3.8 331 9 326 165 0.6 0.1 0.9 0.2 04/18/2006 23:30:00 6.6 0.7 8.4 4.9 6.6 0.9 8.8 3.4 6.4 0.8 8.4 4.6 343 6 341 165 0.4 0 0.7 0.2 04/18/2006 23:40:00 6.1 0.7 7.6 4.6 6.1 0.8 7.6 3 5.9 0.7 7.6 4.2 342 6 333 165 0.4 0 0.7 0.2 04/18/2006 23:50:00 5.7 0.5 6.8 4.6 5.6 0.5 7.2 4.6 5.3 0.5 6.5 3.8 338 5 338 165 0.2 0 0.2 -0.1 04/19/2006 00:00:00 5.3 0.7 7.6 4.2 5.2 0.7 7.2 3.8 5 0.6 7.2 4.2 330 5 336 165 0.2 0 0.4 0.2 04/19/2006 00:10:00 6.7 0.8 8.4 4.6 6.6 0.9 8.4 4.6 6.3 0.9 8.4 4.2 333 8 332 165 0.5 0.1 0.9 0.2 04/19/2006 00:20:00 6.3 0.6 7.6 4.9 6.2 0.6 8 4.9 6.1 0.6 7.6 4.6 334 7 344 165 0.7 0 0.9 0.7 04/19/2006 00:30:00 4.8 0.7 6.8 3 4.7 0.7 6.8 2.6 4.7 0.7 6.8 3 322 9 317 165 0.8 0.1 0.9 0.7 04/19/2006 00:40:00 5.2 1 8 3 4.9 1.1 8.4 3 4.9 1 8 3.4 337 12 350 165 0.6 0 0.9 0.4 04/19/2006 00:50:00 4.9 0.8 7.2 3.4 4.1 1.3 7.6 1.1 4.8 0.8 7.2 3.4 350 7 356 165 0.7 0 0.9 0.7 04/19/2006 01:00:00 4.5 0.7 6.1 3 4.4 0.8 6.1 2.6 4.3 0.7 6.1 3 332 13 340 165 0.3 0.1 0.7 0.2 04/19/2006 01:10:00 3.3 0.6 4.9 1.9 3 0.7 4.9 1.1 3.1 0.5 4.6 1.9 332 20 355 165 0.4 0 0.7 0.2 04/19/2006 01:20:00 1.5 0.5 3.4 0.4 1.1 0.6 3 0.4 1.1 0.6 3 0.4 313 16 341 165 0.5 0 0.7 0.2 04/19/2006 01:30:00 2.9 1.5 5.3 0.4 2.6 1.7 5.3 0.4 2.4 1.7 5.3 0.4 313 11 321 165 0.4 0 0.7 0.2 04/19/2006 01:40:00 3.7 1 5.7 1.5 3.6 1.1 5.7 0.4 3.4 0.9 5.7 1.1 315 12 315 165 0.7 0 0.9 0.7 04/19/2006 01:50:00 3.9 0.6 5.3 2.3 3.8 0.7 5.3 1.9 3.9 0.6 5.3 2.3 321 11 316 165 0.8 0 1.1 0.7 04/19/2006 02:00:00 3.6 0.7 6.1 2.3 3.4 0.8 5.7 1.5 3.5 0.7 5.7 1.9 332 9 330 165 0.9 0 1.1 0.9 04/19/2006 02:10:00 4.5 1.1 6.8 1.9 4.3 1.3 7.6 1.1 4.2 1 6.8 1.9 335 13 347 165 0.9 0 1.1 0.9 04/19/2006 02:20:00 3.8 1.1 6.5 1.9 3.6 1.2 6.5 1.1 3.7 1 5.7 1.9 334 12 344 165 1 0 1.1 0.9 04/19/2006 02:30:00 4.3 0.7 6.5 2.6 4.1 0.7 6.5 2.6 4 0.7 5.7 2.3 324 14 330 165 0.9 0 1.1 0.9 04/19/2006 02:40:00 4.3 0.5 6.1 3 4.2 0.5 6.1 3 4.1 0.5 5.3 3 314 6 325 165 0.9 0 1.1 0.9 04/19/2006 02:50:00 4.3 0.7 6.5 2.6 4.2 0.7 6.5 2.3 4 0.7 6.1 2.3 319 9 328 165 1 0 1.4 0.9 04/19/2006 03:00:00 3.9 0.8 5.7 2.3 3.8 0.8 5.7 1.9 3.8 0.8 5.3 2.3 316 8 312 165 0.9 0.1 1.4 0.9 04/19/2006 03:10:00 4.1 0.6 5.7 2.6 3.9 0.6 5.3 2.6 3.7 0.7 5.7 1.9 312 11 305 165 0.8 0 0.9 0.7 04/19/2006 03:20:00 3 0.8 4.9 1.1 2.7 1 4.9 0.4 3 0.8 4.9 1.1 335 26 305 165 0.8 0 0.9 0.7 04/19/2006 03:30:00 3.8 0.5 4.9 2.3 2.9 0.8 4.9 1.1 4 0.4 5.3 3 356 8 358 165 1.1 0.1 1.4 0.9 04/19/2006 03:40:00 3.4 0.5 4.6 1.9 2.7 0.7 4.6 1.1 3.6 0.6 4.9 1.9 343 16 334 165 1.2 0 1.4 0.9 04/19/2006 03:50:00 3 0.5 4.2 1.9 2.6 0.7 4.2 0.7 3.1 0.4 4.6 2.3 335 21 15 165 0.8 0.1 1.4 0.7 04/19/2006 04:00:00 2.3 0.4 3.4 1.5 2 0.5 3.4 1.1 2.4 0.4 3.4 1.5 331 14 309 165 0.7 0 0.9 0.7 04/19/2006 04:10:00 3.1 0.5 4.2 1.9 2.7 0.6 4.2 1.5 3.1 0.5 4.2 1.5 338 10 348 165 0.7 0 0.9 0.7 04/19/2006 04:20:00 3.7 0.6 4.9 2.3 3.6 0.6 4.9 2.3 3.6 0.6 5.3 1.9 328 10 344 165 0.7 0.1 1.1 0.7 04/19/2006 04:30:00 3.9 0.7 5.7 2.6 3.8 0.7 5.7 1.9 3.7 0.8 5.3 1.9 307 12 317 165 1 0 1.4 0.9 04/19/2006 04:40:00 5.7 0.7 7.2 4.2 5.6 0.7 7.2 3.8 5.5 0.7 7.2 3.8 317 7 319 165 0.8 0 1.1 0.7 04/19/2006 04:50:00 6.3 0.6 8 4.9 6.2 0.6 8 4.9 6.1 0.5 8 4.6 319 7 308 165 0.7 0 0.9 0.7 04/19/2006 05:00:00 6.8 0.7 8.8 5.3 6.6 0.6 8.4 4.9 6.3 0.6 8.4 4.6 316 5 314 165 0.8 0 0.9 0.7 04/19/2006 05:10:00 5.8 0.7 7.6 4.2 5.7 0.7 7.6 4.2 5.5 0.6 7.6 4.2 316 6 325 165 0.8 0 0.9 0.7 04/19/2006 05:20:00 6.5 0.7 8 4.6 6.4 0.7 8 4.2 6.1 0.8 8 4.2 316 7 316 165 0.8 0 0.9 0.7 04/19/2006 05:30:00 5.1 0.8 7.2 3.4 5 0.8 6.8 3.4 4.9 0.6 7.2 3.4 333 10 317 165 0.8 0 0.9 0.7 04/19/2006 05:40:00 5.5 1.1 8 3 5.3 1.2 8 2.3 4.7 0.8 7.2 2.6 316 15 302 165 0.8 0 0.9 0.7 04/19/2006 05:50:00 7.6 0.9 9.9 4.6 7.5 1 9.5 4.6 6 1 9.1 3.4 303 6 304 165 0.8 0 0.9 0.7 04/19/2006 06:00:00 7.3 0.9 9.5 4.9 7.2 0.8 9.5 4.9 5.8 0.9 8 3.8 303 5 295 165 0.8 0 1.1 0.7 04/19/2006 06:10:00 7.1 0.7 8.8 5.3 7.1 0.7 8.8 5.3 5.2 0.7 6.8 3.8 300 5 299 165 0.8 0 0.9 0.9 04/19/2006 06:20:00 5.3 1 7.2 3 5.1 1 7.2 3 4.4 0.8 6.8 2.6 307 8 299 165 0.8 0 0.9 0.7 04/19/2006 06:30:00 3.1 0.8 6.5 1.5 2.9 1 6.8 0.7 3 0.8 5.7 0.7 290 13 287 165 0.9 0 1.1 0.7 04/19/2006 06:40:00 4.1 0.7 5.7 2.3 4 0.7 5.7 1.9 3.8 0.6 5.7 2.3 312 9 305 165 1.3 0.2 1.6 0.9 04/19/2006 06:50:00 4.5 1 6.8 2.6 4.4 1 6.8 2.6 3.9 0.7 5.7 1.9 303 11 290 165 1.5 0 1.8 1.4 04/19/2006 07:00:00 5.6 0.9 8.4 3.8 5.5 0.9 8 3.4 5.1 0.9 8 3.4 310 10 337 165 1.8 0 2.1 1.6 04/19/2006 07:10:00 6.2 1.2 8.8 3.8 5.8 1.2 8.4 3 5.6 1.2 8.4 3 320 9 326 165 2.1 0 2.3 1.8 04/19/2006 07:20:00 6.8 0.8 9.9 4.9 6.5 0.8 9.9 4.6 5.8 1.1 8.8 3.4 312 8 313 165 2 0 2.3 1.8 04/19/2006 07:30:00 6.8 0.7 8.8 4.9 6.5 0.7 8.4 4.6 5.3 1 8.8 3.4 304 8 326 165 1.9 0 2.1 1.8 04/19/2006 07:40:00 6.8 0.8 9.1 4.6 6.6 0.8 8.8 4.6 6.1 1.1 8.8 3.4 289 8 301 165 1.8 0 1.8 1.4 04/19/2006 07:50:00 5.6 1 8.4 3 5.5 0.9 8.4 3.8 5.1 1.2 8 3 288 10 310 165 1.7 0.1 1.8 1.4 04/19/2006 08:00:00 4.9 0.9 7.2 2.6 4.7 0.9 6.8 2.3 3.9 1 6.1 1.5 294 9 289 165 2.2 0.2 2.8 1.6 04/19/2006 08:10:00 3.6 0.7 5.3 1.5 3.3 0.9 5.3 0.7 3.1 0.8 4.9 1.1 302 22 299 165 2.9 0.1 3.3 2.6 04/19/2006 08:20:00 3.9 0.8 6.1 2.3 3.6 0.8 6.1 1.5 3.3 0.8 4.9 1.5 318 21 297 165 3.5 0.3 4 2.8 04/19/2006 08:30:00 4.4 0.8 6.8 2.3 4.2 0.9 6.8 2.3 3.5 0.9 6.1 1.9 307 13 319 165 2.7 0.2 3.5 2.3 04/19/2006 08:40:00 5.2 1 8.8 2.6 5.2 1 8.4 3 5.2 1.2 8.4 2.3 304 24 282 165 2.1 0.2 2.6 1.6 04/19/2006 08:50:00 7.8 1.2 10.3 4.6 7.8 1.2 10.3 4.9 6.9 1.1 9.9 3.4 292 6 292 165 1.7 0 1.8 1.4 04/19/2006 09:00:00 8.3 0.7 10.7 6.5 8.3 0.7 10.3 6.1 6.8 0.9 9.5 4.6 296 5 297 165 1.5 0 1.8 1.1 04/19/2006 09:10:00 7.2 1 9.5 4.9 7.2 1 9.5 4.9 5.6 0.9 8 3.4 297 5 295 165 1.8 0 2.1 1.4 04/19/2006 09:20:00 6.3 1 8.8 4.6 6.3 1 8.4 4.6 5 0.8 7.2 3 296 7 287 165 1.9 0.1 2.1 1.4 04/19/2006 09:30:00 4.1 0.8 6.1 2.3 4.1 0.8 6.1 2.6 3.7 0.9 6.1 1.9 303 18 341 165 2.7 0.5 3.5 1.8 04/19/2006 09:40:00 4.2 0.8 5.7 1.9 4 0.8 5.7 1.5 3.9 0.8 5.3 1.1 331 19 304 165 4 0.3 4.5 3 04/19/2006 09:50:00 3 1 5.3 1.1 3 1.1 5.3 0.7 2.7 1.1 5.3 0.4 298 32 282 165 4.2 0.5 5 3 04/19/2006 10:00:00 4.6 0.8 6.8 2.6 4.6 0.8 6.5 2.6 3.8 0.7 6.1 1.9 294 11 296 165 2.7 0.3 3.3 2.3 04/19/2006 10:10:00 5.1 0.5 6.1 3 5 0.5 6.5 2.6 4.3 0.7 5.7 2.3 305 7 314 165 3.1 0.1 3.5 2.8 04/19/2006 10:20:00 5.3 0.5 6.5 4.2 5.3 0.5 6.5 3.8 4.1 0.5 5.7 2.6 300 6 304 165 3.2 0.1 3.5 3 04/19/2006 10:30:00 5.2 0.6 6.8 3.8 5.2 0.5 6.8 3.8 4.3 0.6 6.5 2.6 302 8 306 165 3 0 3.3 2.8 04/19/2006 10:40:00 4.1 0.5 5.7 2.6 4.1 0.5 5.7 2.6 3.5 0.5 4.9 2.3 296 6 302 165 2.7 0.1 3 2.6 04/19/2006 10:50:00 4 0.5 5.7 3 4.1 0.5 5.3 3 3.5 0.6 5.3 1.9 294 7 286 165 2.7 0 2.8 2.6 04/19/2006 11:00:00 4.5 0.6 5.7 2.3 4.5 0.7 6.1 2.3 3.7 0.6 5.3 1.9 296 8 296 165 2.9 0 3.3 2.8 04/19/2006 11:10:00 4.5 0.4 5.7 3.4 4.5 0.4 5.3 3.4 3.7 0.7 5.3 2.3 305 9 314 165 2.9 0.1 3.3 2.6 04/19/2006 11:20:00 3.3 0.8 5.7 1.5 3.2 0.8 5.7 1.1 3 0.9 4.9 1.1 312 8 305 165 3.7 0.3 4.3 3 04/19/2006 11:30:00 2.8 0.9 4.6 0.7 2.3 0.8 4.2 0.4 2.8 1 4.9 0.7 357 21 15 165 4.6 0.3 5.5 3.8 04/19/2006 11:40:00 2.8 0.8 4.9 1.1 2.3 0.8 4.2 0.4 2.6 0.8 4.6 0.7 6 17 3 165 4.9 0.2 5.5 4.5 04/19/2006 11:50:00 2.7 0.5 3.8 1.5 2.3 0.5 3.4 1.1 2.5 0.6 3.8 0.4 2 22 356 165 4.3 0.2 4.8 4.3 04/19/2006 12:00:00 1.5 1 5.7 0.4 1.5 1.1 5.3 0.4 1.5 1 4.9 0.4 97 51 116 165 4.6 0.4 5.2 4.3 04/19/2006 12:10:00 1.8 0.7 3.4 0.4 1.7 0.8 3.4 0.4 1.6 0.8 3.4 0.4 58 47 29 165 4.9 0.5 5.7 4.3 04/19/2006 12:20:00 1.5 0.7 4.2 0.4 1.4 0.8 3.8 0.4 1.6 0.8 4.6 0.4 106 58 122 165 4.6 0.7 6.7 3.8 04/19/2006 12:30:00 2.1 0.7 3.8 0.4 2 0.7 3.8 0.4 2 0.7 4.2 0.4 46 98 164 165 6.2 0.1 6.7 5.7 04/19/2006 12:40:00 1.5 0.9 4.2 0.4 1.4 0.9 3.8 0.4 1.2 0.8 3.4 0.4 96 45 94 165 5.3 0.2 6 5 04/19/2006 12:50:00 1.5 0.9 4.2 0.4 1.3 1 4.2 0.4 1.3 1 3.8 0.4 148 94 147 165 4.9 0.3 5.5 4.5 04/19/2006 13:00:00 2 1 3.8 0.4 2 1 3.8 0.4 2 0.9 4.2 0.4 173 10 170 165 4.2 0.1 4.8 3.8 04/19/2006 13:10:00 2.6 0.5 4.2 1.5 2.6 0.5 4.2 1.5 2.6 0.5 4.2 1.5 167 12 165 165 3.8 0.1 4.3 3.5 04/19/2006 13:20:00 3.6 0.6 4.9 2.3 3.6 0.6 4.9 2.3 3.6 0.5 4.9 2.3 154 8 164 165 3.5 0 3.5 3.3 04/19/2006 13:30:00 3.9 0.4 5.3 2.6 3.8 0.5 5.3 3 3.9 0.5 5.7 2.3 160 7 157 165 3.3 0 3.5 2.8 04/19/2006 13:40:00 4 0.6 6.1 2.6 4 0.6 6.1 2.6 4 0.6 6.1 2.6 140 17 125 165 3.3 0 3.5 2.8 04/19/2006 13:50:00 3.8 0.5 5.3 1.9 3.8 0.6 5.3 1.9 3.9 0.5 5.3 2.6 131 8 121 165 3.6 0.1 4 3.3 04/19/2006 14:00:00 3.9 0.6 5.7 2.6 3.9 0.6 5.7 2.3 4 0.6 5.7 1.9 129 10 137 165 3.8 0.2 4.3 3.3 04/19/2006 14:10:00 3.6 0.6 5.3 1.5 3.6 0.7 5.3 1.5 3.6 0.7 5.3 1.9 126 10 127 165 3.5 0.1 3.8 3.3 04/19/2006 14:20:00 3.7 0.6 5.3 1.9 3.7 0.7 5.3 1.9 3.8 0.8 5.3 1.5 142 12 155 165 3.5 0 3.8 3.3 04/19/2006 14:30:00 4.8 0.6 6.8 3 4.7 0.6 6.5 3 4.8 0.6 6.5 3 150 10 147 165 3.2 0 3.5 2.6 04/19/2006 14:40:00 5.2 0.3 6.1 4.6 5.1 0.4 6.1 4.2 5.2 0.4 6.1 4.2 151 5 146 165 2.8 0 3.3 2.6 04/19/2006 14:50:00 5.4 0.5 6.5 4.2 5.3 0.5 6.5 4.2 5.5 0.5 6.5 4.2 150 5 153 165 2.8 0.2 3 1.8 04/19/2006 15:00:00 5.4 0.3 6.1 4.9 5.3 0.3 6.1 4.6 5.5 0.3 6.1 4.6 150 3 146 165 2.4 0 2.6 2.3 04/19/2006 15:10:00 5.7 0.4 6.5 4.6 5.6 0.4 6.8 4.6 5.7 0.5 6.8 4.6 151 3 156 165 2.5 0 2.8 2.3 04/19/2006 15:20:00 6.5 0.4 7.6 5.7 6.4 0.4 7.2 5.3 6.6 0.4 7.6 5.7 151 3 151 165 2.7 0 2.8 2.3 04/19/2006 15:30:00 6.9 0.4 8 5.7 6.8 0.4 7.6 5.3 7 0.4 8.4 5.7 151 3 155 165 2.4 0.1 2.8 2.3 04/19/2006 15:40:00 7 0.4 8 5.7 6.9 0.4 7.6 5.7 7.1 0.5 8.4 6.1 153 3 152 165 2.3 0 2.6 2.1 04/19/2006 15:50:00 6.5 0.4 7.6 5.3 6.4 0.4 7.2 5.3 6.6 0.4 7.6 5.7 149 4 148 165 2.1 0.1 2.6 1.8 04/19/2006 16:00:00 5.7 0.5 6.5 3.8 5.7 0.5 6.8 4.2 5.8 0.5 6.8 4.2 148 5 146 165 2 0.2 2.6 1.6 04/19/2006 16:10:00 5.2 0.4 6.5 4.2 5.1 0.4 6.1 4.2 5.3 0.4 6.5 3.8 151 6 149 165 1.8 0.1 2.1 1.4 04/19/2006 16:20:00 4.8 0.6 6.1 3 4.8 0.6 6.5 3 4.9 0.6 6.5 3.4 146 8 157 165 1.5 0.1 1.8 0.9 04/19/2006 16:30:00 4.2 0.3 5.3 3.4 4.1 0.3 4.9 3.4 4.2 0.4 5.7 3.4 148 7 158 165 1.4 0 1.6 1.1 04/19/2006 16:40:00 4.7 0.4 6.1 3.8 4.7 0.5 6.1 3.8 4.8 0.5 6.1 3.8 146 7 137 165 1.4 0 1.6 1.1 04/19/2006 16:50:00 4.8 0.5 6.1 3.8 4.8 0.5 6.1 3.8 4.8 0.5 6.1 3.8 140 6 131 165 1.4 0 1.8 0.9 04/19/2006 17:00:00 5 0.5 6.5 3.8 5 0.5 6.5 3.8 5.1 0.5 6.1 3.8 144 8 139 165 1.7 0.1 2.1 1.4 04/19/2006 17:10:00 4.5 0.5 5.7 3 4.6 0.5 5.7 3.4 4.4 0.5 6.1 3.4 141 8 143 165 1.8 0 1.8 1.4 04/19/2006 17:20:00 4.3 0.4 5.3 3.4 4.4 0.4 5.3 3.4 4.4 0.4 6.1 3.4 137 8 133 165 1.8 0 1.8 1.4 04/19/2006 17:30:00 4.5 0.6 6.5 3 4.6 0.6 6.5 3 4.4 0.6 6.1 3 131 8 135 165 1.6 0 1.8 1.4 04/19/2006 17:40:00 5 0.8 6.8 3.4 5 0.8 6.8 3 4.9 0.6 6.5 3.8 140 9 138 165 1.7 0 1.8 1.4 04/19/2006 17:50:00 5.6 0.5 6.5 4.2 5.6 0.5 6.8 4.2 5.6 0.6 6.8 3.8 140 6 148 165 1.8 0 1.8 1.4 04/19/2006 18:00:00 6.1 0.5 7.6 4.6 6.1 0.5 7.6 4.6 6.1 0.6 7.6 4.2 144 7 144 165 1.9 0 1.8 1.8 04/19/2006 18:10:00 6.5 0.5 8 5.3 6.5 0.5 8 5.3 6.4 0.6 7.6 4.6 144 5 145 165 1.9 0 2.1 1.8 04/19/2006 18:20:00 5.6 0.5 6.8 4.2 5.7 0.5 7.2 3.8 5.6 0.6 6.8 3.4 142 6 148 165 1.9 0 2.1 1.8 04/19/2006 18:30:00 5.5 0.6 6.8 4.2 5.6 0.5 7.2 4.2 5.5 0.5 6.8 4.2 143 6 136 165 1.9 0 2.1 1.8 04/19/2006 18:40:00 5.8 0.5 6.8 4.2 5.8 0.5 6.8 4.6 5.8 0.6 7.2 4.2 150 5 148 165 1.8 0.1 2.1 1.4 04/19/2006 18:50:00 5.2 0.5 6.5 3.8 5.3 0.5 6.5 4.2 5.2 0.5 6.5 3.8 142 5 149 165 1.6 0 1.8 1.4 04/19/2006 19:00:00 5.7 0.5 7.2 4.6 5.8 0.5 6.8 4.2 5.8 0.6 7.2 4.2 146 5 147 165 1.7 0 1.8 1.4 04/19/2006 19:10:00 5.8 0.6 7.2 4.2 5.9 0.6 6.8 4.2 5.7 0.6 6.8 3.8 145 5 146 165 1.7 0 1.8 1.4 04/19/2006 19:20:00 5.9 0.5 7.2 4.2 5.9 0.5 7.2 4.2 5.8 0.6 7.2 3.8 148 5 151 165 1.8 0.1 1.8 1.4 04/19/2006 19:30:00 5.6 0.5 6.8 4.2 5.7 0.5 6.8 4.2 5.5 0.6 7.2 4.2 145 6 143 165 1.9 0.1 2.1 1.4 04/19/2006 19:40:00 5.6 0.4 6.8 4.6 5.7 0.4 6.8 4.6 5.5 0.5 6.8 4.2 143 5 151 165 1.8 0.1 1.8 1.4 04/19/2006 19:50:00 6.1 0.4 6.8 4.9 6.2 0.4 6.8 5.3 6.2 0.4 7.2 4.9 145 4 151 165 1.8 0 1.8 1.8 04/19/2006 20:00:00 6.2 0.4 7.2 4.6 6.2 0.4 7.2 4.9 6.3 0.5 7.2 4.9 148 4 152 165 1.8 0 2.3 1.6 04/19/2006 20:10:00 5.9 0.4 7.2 4.6 5.8 0.4 6.8 4.6 6.1 0.5 7.2 4.6 151 5 158 165 1.7 0 1.8 1.6 04/19/2006 20:20:00 3.8 1.3 6.5 0.4 3.8 1.4 6.1 0.7 3.8 1.3 6.5 1.1 187 30 164 165 1.7 0 1.8 1.6 04/19/2006 20:30:00 3.5 0.8 5.7 1.9 3.4 0.8 5.3 1.9 3.7 0.6 5.7 2.3 180 13 164 165 1.7 0 1.8 1.6 04/19/2006 20:40:00 2.3 0.4 3.4 1.5 2.2 0.4 3.4 1.1 2.7 0.4 3.4 1.9 173 11 179 165 1.5 0 1.8 1.4 04/19/2006 20:50:00 1.5 0.4 2.6 0.4 1.3 0.5 2.6 0.4 1.8 0.4 2.6 0.7 176 9 179 165 1.4 0 1.6 1.4 04/19/2006 21:00:00 1.1 0.4 1.9 0.4 0.9 0.4 1.9 0.4 1.4 0.4 2.3 0.7 162 6 156 165 1.2 0 1.4 1.1 04/19/2006 21:10:00 1.4 0.9 3.4 0.4 1.3 0.9 3 0.4 1.5 0.9 3.4 0.4 189 9 197 165 1.1 0 1.4 0.9 04/19/2006 21:20:00 2.7 0.6 4.2 1.5 2.7 0.6 4.2 1.1 2.9 0.5 4.2 1.5 188 8 191 165 1.3 0 1.6 1.1 04/19/2006 21:30:00 3.2 0.3 3.8 2.6 3.1 0.3 3.8 2.3 3.4 0.4 4.2 2.3 171 5 169 165 1.2 0 1.4 1.1 04/19/2006 21:40:00 3 0.4 4.2 1.9 3 0.4 4.2 1.9 3.3 0.4 4.2 2.3 167 4 165 165 1.1 0 1.4 0.9 04/19/2006 21:50:00 3.1 0.8 5.3 1.1 3 0.8 4.9 1.1 3.4 0.7 5.3 1.9 174 10 176 165 1.1 0 1.4 0.9 04/19/2006 22:00:00 1.7 0.4 3 0.7 1.7 0.5 2.6 0.4 2.1 0.3 3 1.5 174 11 166 165 0.8 0 1.1 0.7 04/19/2006 22:10:00 2 0.4 2.6 0.7 1.9 0.5 2.6 0.4 2.1 0.5 3 0.4 140 11 129 165 0.5 0 0.7 0.4 04/19/2006 22:20:00 1.9 0.3 3 0.7 1.8 0.4 3.4 0.4 2.2 0.3 3 1.5 142 9 137 165 0.6 0 0.7 0.4 04/19/2006 22:30:00 2.9 0.4 4.2 1.9 2.9 0.4 3.8 1.9 3.2 0.4 4.2 2.3 135 6 136 165 0.6 0 0.9 0.4 04/19/2006 22:40:00 2.5 0.4 3.4 1.1 2.4 0.5 3 1.1 2.8 0.4 3.4 1.5 149 8 136 165 0.5 0 0.7 0.4 04/19/2006 22:50:00 1.7 0.5 3 0.7 1.5 0.7 3 0.4 2.1 0.5 3.4 0.7 137 14 142 165 0.4 0.1 0.7 0.2 04/19/2006 23:00:00 1.7 0.4 2.6 0.7 1.6 0.5 2.6 0.4 2 0.3 2.6 1.1 136 11 116 165 0.1 0.1 0.4 -0.3 04/19/2006 23:10:00 2.6 0.5 3.4 1.1 2.5 0.6 3.4 0.4 2.7 0.6 3.8 0.7 126 8 123 165 -0.2 0 0.2 -0.3 04/19/2006 23:20:00 2.8 0.5 3.8 1.5 2.7 0.6 3.8 0.7 2.9 0.6 4.6 1.1 134 11 120 165 0 0 0.2 -0.1 04/19/2006 23:30:00 2.2 0.4 3.4 1.5 2.1 0.4 3.4 1.1 2.5 0.4 3.4 1.5 133 9 136 165 -0.2 0 -0.1 -0.3 04/19/2006 23:40:00 2.1 0.5 3.4 0.7 2 0.6 3.4 0.4 2.4 0.5 3.4 1.1 131 10 145 165 -0.3 0 -0.1 -0.5 04/19/2006 23:50:00 1.7 0.3 2.3 0.7 1.5 0.4 2.3 0.4 1.9 0.4 2.6 0.7 109 9 115 165 -0.3 0 -0.3 -0.5 04/20/2006 00:00:00 2.5 0.5 3.4 1.5 2.6 0.5 3.8 1.1 2.8 0.5 3.8 1.9 120 7 117 165 -0.5 0 -0.3 -0.5 04/20/2006 00:10:00 2.9 0.5 4.2 1.9 3 0.5 4.2 1.9 3 0.4 4.2 1.9 129 6 126 165 -0.5 0 -0.3 -0.8 04/20/2006 00:20:00 3.3 0.3 4.2 2.6 3.4 0.3 4.2 2.6 3.5 0.4 4.2 2.3 131 7 130 165 -0.6 0 -0.5 -0.8 04/20/2006 00:30:00 2.9 0.5 4.2 1.9 3 0.6 4.2 1.9 3 0.6 4.2 1.5 134 14 128 165 -0.7 0 -0.5 -0.8 04/20/2006 00:40:00 2 1 3.8 0.4 2 1.1 3.8 0.4 2.3 1 4.6 0.4 147 6 144 165 -0.7 0 -0.5 -0.8 04/20/2006 00:50:00 0.4 0.1 1.1 0.4 0.4 0 0.7 0.4 0.5 0.2 1.1 0.4 159 5 143 165 -0.8 0 -0.5 -0.8 04/20/2006 01:00:00 0.9 0.5 1.9 0.4 0.7 0.4 1.9 0.4 1.2 0.5 2.6 0.4 170 4 165 165 -0.9 0 -0.8 -1 04/20/2006 01:10:00 0.4 0.1 1.1 0.4 0.4 0.1 1.1 0.4 0.5 0.3 1.5 0.4 156 9 170 165 -1.1 0 -0.8 -1.2 04/20/2006 01:20:00 0.6 0.4 1.5 0.4 0.5 0.2 1.1 0.4 0.7 0.4 1.5 0.4 190 69 151 165 -1.3 0 -1.2 -1.4 04/20/2006 01:30:00 1.7 0.6 3 0.4 1.3 0.5 2.6 0.4 1.8 0.5 3 0.7 335 10 349 165 -1.5 0 -1.4 -1.7 04/20/2006 01:40:00 2.6 0.2 3 2.3 1.2 0.5 2.6 0.4 2.7 0.2 3 2.3 356 5 349 165 -1.6 0 -1.4 -1.7 04/20/2006 01:50:00 2.3 0.3 3 1.5 0.9 0.5 2.6 0.4 2.3 0.4 3 1.5 5 4 12 165 -1.6 0 -1.4 -1.9 04/20/2006 02:00:00 1.4 0.2 1.9 1.1 0.4 0.2 1.1 0.4 1.6 0.2 1.9 1.1 3 0 4 165 -1.6 0 -1.4 -1.7 04/20/2006 02:10:00 1.1 0.4 2.3 0.4 0.8 0.5 2.3 0.4 1.2 0.3 2.3 0.4 321 29 294 165 -1.4 0.1 -1.2 -1.7 04/20/2006 02:20:00 3.1 0.5 3.8 1.9 3 0.5 4.2 1.5 2.5 0.5 3.4 1.1 292 8 287 165 -1.2 0 -1 -1.4 04/20/2006 02:30:00 3.7 0.4 4.9 2.6 3.6 0.4 4.9 2.3 3.3 0.5 4.6 1.9 293 4 291 165 -1.1 0 -1 -1.2 04/20/2006 02:40:00 4.2 0.3 4.9 3.4 4.2 0.3 5.3 3.4 3.7 0.5 4.9 2.6 290 3 292 165 -1 0 -0.8 -1.2 04/20/2006 02:50:00 4.1 0.6 5.3 2.6 4 0.6 4.9 2.3 3 0.4 4.2 1.9 299 4 300 165 -0.9 0 -0.8 -1.2 04/20/2006 03:00:00 2.9 0.5 4.2 1.9 2.7 0.6 4.2 1.5 2.4 0.4 3.4 1.5 300 6 295 165 -0.9 0 -0.8 -1.2 04/20/2006 03:10:00 2.5 0.3 3 1.9 2.3 0.4 3 1.5 2.3 0.4 3 1.5 305 7 302 165 -0.9 0 -0.8 -1 04/20/2006 03:20:00 1.5 0.6 2.6 0.4 1.2 0.6 2.6 0.4 1.6 0.6 3 0.7 314 9 317 165 -0.9 0 -0.8 -0.8 04/20/2006 03:30:00 0.8 0.5 2.6 0.4 0.7 0.7 3 0.4 1.2 0.6 3.4 0.4 282 10 274 165 -0.6 0 -0.5 -0.8 04/20/2006 03:40:00 1.7 0.5 3 0.4 2 0.5 3 1.1 2.3 0.4 3.4 1.5 252 8 244 165 -0.6 0 -0.5 -0.8 04/20/2006 03:50:00 2.4 0.4 3.4 1.5 2.3 0.4 3 1.5 2.6 0.3 3.4 1.9 241 2 240 165 -1 0 -0.8 -1.2 04/20/2006 04:00:00 2.7 0.3 3.4 1.9 2.7 0.3 3.4 1.9 3.1 0.3 3.8 2.3 236 12 245 165 -1 0 -0.8 -1.2 04/20/2006 04:10:00 2.1 0.3 2.6 1.5 2 0.3 2.6 1.5 2.4 0.3 3 1.9 213 2 215 165 -1.2 0 -1 -1.2 04/20/2006 04:20:00 2.4 0.3 3 1.5 2.3 0.3 3 1.5 2.6 0.3 3.4 1.5 200 6 194 165 -1 0 -0.8 -1.2 04/20/2006 04:30:00 1.9 0.6 3 0.7 1.9 0.6 3 0.7 2.3 0.5 3.4 1.5 195 8 196 165 -1.2 0 -1 -1.4 04/20/2006 04:40:00 0.9 0.4 2.3 0.4 0.9 0.4 2.3 0.4 1.4 0.3 2.6 0.7 236 39 319 165 -1.3 0 -1.2 -1.4 04/20/2006 04:50:00 2 0.3 2.6 1.5 1.8 0.3 2.6 1.1 2.2 0.3 2.6 1.9 317 2 314 165 -1.4 0 -1.2 -1.4 04/20/2006 05:00:00 0.5 0.3 1.5 0.4 0.4 0.2 1.1 0.4 0.8 0.5 1.9 0.4 318 0 318 165 -1.5 0 -1.4 -1.7 04/20/2006 05:10:00 0.5 0.3 1.5 0.4 0.5 0.2 1.5 0.4 0.9 0.4 1.9 0.4 181 38 166 165 -1.4 0 -1.2 -1.7 04/20/2006 05:20:00 1.3 0.4 2.3 0.4 1.2 0.4 2.3 0.4 1.6 0.3 2.3 0.7 124 13 134 165 -1.3 0 -1 -1.4 04/20/2006 05:30:00 2.3 0.2 2.6 1.5 2.5 0.2 3 1.5 2.6 0.3 3 1.9 136 2 135 165 -1.2 0 -1 -1.2 04/20/2006 05:40:00 2.4 0.3 3 1.5 2.5 0.3 3 1.5 2.7 0.2 3 1.9 139 4 141 165 -1.1 0 -1 -1.2 04/20/2006 05:50:00 1.9 0.3 2.6 0.7 2.1 0.3 2.6 1.1 2.4 0.3 3 1.5 149 6 147 165 -1 0 -0.8 -1.2 04/20/2006 06:00:00 1.7 0.2 2.3 1.1 1.8 0.3 2.6 1.1 2.2 0.2 3 1.9 149 9 143 165 -1.1 0 -1 -1.2 04/20/2006 06:10:00 0.7 0.4 1.9 0.4 0.7 0.5 1.9 0.4 1.4 0.4 2.3 0.7 154 3 153 165 -1.1 0 -1 -1.2 04/20/2006 06:20:00 1.1 0.5 1.9 0.4 1.3 0.5 2.3 0.4 1.8 0.3 2.3 0.7 161 3 160 165 -1.1 0 -1 -1.2 04/20/2006 06:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0.1 1.1 0.4 158 0 165 165 -1 0 -0.8 -1.2 04/20/2006 06:40:00 0.5 0.4 1.9 0.4 0.5 0.4 1.5 0.4 0.9 0.5 2.3 0.4 157 2 152 165 -0.9 0 -0.8 -1.2 04/20/2006 06:50:00 1.2 0.4 2.3 0.4 1.2 0.4 2.3 0.4 1.7 0.3 2.6 0.7 149 7 149 165 -0.9 0 -0.8 -1.2 04/20/2006 07:00:00 1.7 0.5 3 0.4 1.8 0.5 3 0.4 2.1 0.5 3.4 0.7 142 7 138 165 -0.9 0 -0.8 -1 04/20/2006 07:10:00 1.9 0.3 3 1.1 2 0.3 3 1.1 2.3 0.3 3 1.9 137 9 145 165 -0.9 0 -0.8 -1 04/20/2006 07:20:00 2.2 0.4 3.4 0.7 2.3 0.5 3.4 1.1 2.5 0.4 3.4 1.5 148 9 150 165 -0.8 0 -0.5 -1 04/20/2006 07:30:00 2.4 0.4 3.4 1.5 2.5 0.4 3.4 1.5 2.7 0.3 3.8 1.9 150 9 150 165 -0.6 0 -0.5 -0.8 04/20/2006 07:40:00 2.6 0.5 4.2 1.9 2.7 0.4 4.2 1.5 3 0.4 4.2 2.3 152 7 147 165 -0.5 0 -0.5 -0.8 04/20/2006 07:50:00 3.1 0.5 4.2 1.9 3.1 0.5 4.6 1.9 3.5 0.5 4.6 2.3 157 5 154 165 -0.5 0 -0.3 -0.8 04/20/2006 08:00:00 2.5 0.4 3.4 1.9 2.6 0.3 3.4 1.9 2.9 0.3 3.4 2.3 159 5 154 165 -0.5 0 -0.3 -0.8 04/20/2006 08:10:00 2.6 0.3 3.4 1.9 2.6 0.3 3.4 1.9 2.9 0.3 3.4 2.3 160 6 159 165 -0.5 0 -0.3 -0.5 04/20/2006 08:20:00 2.6 0.3 3.4 1.9 2.5 0.2 3 1.9 2.8 0.2 3.4 2.3 159 6 164 165 -0.5 0 -0.3 -0.5 04/20/2006 08:30:00 2.8 0.5 4.2 1.9 2.8 0.4 3.8 1.9 3.2 0.4 4.2 2.3 157 11 155 165 -0.3 0 -0.3 -0.5 04/20/2006 08:40:00 3.5 0.3 4.2 3 3.4 0.3 4.2 3 3.8 0.3 4.6 3 159 3 161 165 -0.3 0 -0.3 -0.5 04/20/2006 08:50:00 3.1 0.4 3.8 1.9 3.1 0.4 3.8 1.9 3.5 0.3 4.6 2.6 159 5 162 165 -0.3 0 -0.1 -0.5 04/20/2006 09:00:00 2.6 0.5 3.8 1.5 2.5 0.5 3.8 1.1 3 0.4 4.2 1.9 158 15 125 165 -0.1 0 0.2 -0.3 04/20/2006 09:10:00 2.2 0.8 3.4 0.4 2.2 0.8 3.4 0.4 2.7 0.7 4.2 1.1 152 9 143 165 -0.1 0 0.2 -0.1 04/20/2006 09:20:00 3 0.6 4.2 1.1 3 0.6 4.2 1.1 3.3 0.5 4.6 1.9 153 8 152 165 0.1 0 0.2 -0.1 04/20/2006 09:30:00 3 0.4 4.2 1.9 3.1 0.5 4.2 1.9 3.4 0.4 4.6 2.3 150 10 160 165 0.4 0.1 0.9 0.2 04/20/2006 09:40:00 3.7 0.5 4.9 2.6 3.7 0.5 4.9 2.6 3.9 0.4 5.3 2.6 142 6 143 165 0.7 0 0.9 0.7 04/20/2006 09:50:00 4.8 0.5 5.7 3.4 4.7 0.5 5.7 3.4 5 0.5 6.1 3.4 144 6 145 165 0.8 0 1.4 0.7 04/20/2006 10:00:00 5.1 0.5 6.5 3.8 5.1 0.5 6.5 3.8 5.3 0.5 6.8 4.2 148 5 150 165 1.3 0 1.4 1.1 04/20/2006 10:10:00 4.8 0.4 5.7 3.8 4.8 0.4 6.1 3.8 4.9 0.4 6.1 3.8 144 5 139 165 1.3 0 1.6 1.1 04/20/2006 10:20:00 4.5 0.4 5.7 3.4 4.5 0.4 5.7 3.4 4.6 0.4 5.7 3.4 147 6 154 165 1.1 0 1.4 0.9 04/20/2006 10:30:00 4.5 0.4 5.7 3.4 4.4 0.4 5.7 3.4 4.6 0.4 5.7 3 148 7 148 165 1.2 0 1.4 0.9 04/20/2006 10:40:00 4.7 0.5 6.1 3.4 4.6 0.5 5.7 3.4 4.8 0.4 6.1 3.8 149 5 153 165 1.1 0 1.4 0.9 04/20/2006 10:50:00 4.8 0.4 6.1 3.8 4.6 0.4 6.1 3.4 4.8 0.4 5.7 3.8 151 4 151 165 0.9 0.1 1.4 0.7 04/20/2006 11:00:00 5.1 0.4 6.1 4.2 4.9 0.5 5.7 3.8 5.1 0.4 6.1 3.8 151 4 148 165 0.8 0 1.1 0.7 04/20/2006 11:10:00 4.2 0.4 5.3 3.4 4.1 0.4 5.3 3 4.3 0.3 5.7 3.4 148 5 145 165 1 0 1.4 0.9 04/20/2006 11:20:00 4.3 0.5 5.7 3 4.2 0.5 5.7 3 4.5 0.5 5.7 3.4 150 6 142 165 1 0 1.4 0.9 04/20/2006 11:30:00 5.5 0.4 6.5 4.2 5.4 0.4 6.1 4.2 5.6 0.4 6.8 4.2 146 5 148 165 1 0.1 1.4 0.9 04/20/2006 11:40:00 4.4 0.6 6.1 3 4.3 0.5 5.7 2.6 4.6 0.5 6.1 3.4 151 6 153 165 0.9 0 1.4 0.9 04/20/2006 11:50:00 3.8 0.5 4.9 2.3 3.7 0.5 4.9 2.3 4 0.5 5.3 2.6 157 5 159 165 0.9 0 1.1 0.9 04/20/2006 12:00:00 3.4 0.5 4.9 2.3 3.4 0.6 4.9 1.9 3.7 0.5 5.3 2.6 156 8 163 165 1.4 0.2 1.8 0.9 04/20/2006 12:10:00 3.9 0.6 5.3 2.3 3.9 0.7 5.7 2.3 4.1 0.7 5.7 2.3 160 12 167 165 2 0 2.3 1.6 04/20/2006 12:20:00 4.7 1 7.6 2.6 4.6 0.9 7.2 2.6 4.8 0.8 7.2 3.4 169 6 166 165 2.1 0.1 2.6 1.8 04/20/2006 12:30:00 6.6 0.8 8.4 4.9 6.4 0.7 8.4 4.9 6.7 0.7 8.4 4.9 163 6 164 165 1.7 0.2 1.8 1.4 04/20/2006 12:40:00 8.3 0.7 9.9 6.8 8 0.7 9.5 6.5 8.5 0.7 10.3 6.8 164 13 162 165 1 0.1 1.4 0.9 04/20/2006 12:50:00 8 0.7 9.5 6.5 7.7 0.6 9.1 6.1 8.2 0.8 9.9 6.1 172 9 164 165 0.7 0 0.9 0.4 04/20/2006 13:00:00 7.2 0.5 8.4 5.7 7.1 0.5 8.4 5.7 7.4 0.5 8.4 5.7 166 4 164 165 0.8 0.1 1.4 0.4 04/20/2006 13:10:00 6.7 0.5 8.4 4.9 6.5 0.5 8 4.9 6.8 0.5 8 5.3 158 5 158 165 1.2 0 1.6 0.9 04/20/2006 13:20:00 7.4 0.8 9.5 5.3 7.2 0.7 9.5 5.7 7.5 0.7 9.5 5.7 156 5 156 165 1.7 0.1 1.8 1.4 04/20/2006 13:30:00 8.9 0.6 11.8 7.6 8.7 0.6 11.8 7.2 9 0.6 11.1 7.2 162 6 160 165 2.2 0.1 2.6 1.8 04/20/2006 13:40:00 8.2 0.6 9.5 6.8 7.9 0.5 9.5 6.5 8.3 0.6 9.9 6.8 163 5 168 165 2.1 0 2.6 1.8 04/20/2006 13:50:00 8.4 0.6 10.3 6.5 8.2 0.5 9.9 6.5 8.6 0.6 10.3 6.8 164 8 169 165 2.4 0.1 2.8 1.8 04/20/2006 14:00:00 8.3 0.6 9.5 6.5 8.2 0.6 9.5 6.5 8.4 0.7 9.9 6.8 148 6 152 165 2.1 0.1 2.6 1.8 04/20/2006 14:10:00 8.1 0.4 9.1 6.8 7.9 0.4 8.8 6.8 8.2 0.4 9.1 6.8 156 3 159 165 1.7 0 1.8 1.6 04/20/2006 14:20:00 8 0.5 9.5 6.1 7.9 0.6 9.9 6.1 8.2 0.6 9.9 6.8 157 6 154 165 1.8 0.1 2.1 1.4 04/20/2006 14:30:00 8.5 0.7 10.3 6.5 8.5 0.7 10.3 6.5 8.5 0.8 10.3 6.1 156 6 150 165 2.2 0 2.6 1.8 04/20/2006 14:40:00 8.3 0.7 10.3 5.7 8.1 0.7 10.3 5.7 8.4 0.6 9.9 6.8 155 4 159 165 2.2 0 2.6 1.8 04/20/2006 14:50:00 9 1 11.5 7.2 8.9 1 11.1 6.8 9.1 1.1 11.5 6.8 156 5 152 165 2.1 0.1 2.3 1.8 04/20/2006 15:00:00 10.1 0.5 11.5 8.4 9.9 0.5 11.5 8.8 10.2 0.6 11.8 8.4 155 4 150 165 1.9 0 2.1 1.8 04/20/2006 15:10:00 9 0.7 10.7 7.2 9 0.7 10.7 7.2 9.1 0.8 10.7 6.1 152 4 152 165 2.2 0 2.3 1.8 04/20/2006 15:20:00 10.3 0.5 11.8 8.8 10.3 0.5 12.2 8.8 10.5 0.6 12.6 8.8 153 4 154 165 2.3 0 2.6 2.1 04/20/2006 15:30:00 10.2 0.6 11.5 8.4 10.1 0.5 11.8 8.4 10.2 0.8 12.2 7.2 152 4 151 165 2.4 0 2.6 2.3 04/20/2006 15:40:00 10.5 0.7 13 8 10.4 0.8 12.6 8 10.5 0.9 12.6 8 153 5 151 165 2.1 0 2.6 1.8 04/20/2006 15:50:00 8.6 0.9 10.7 6.8 8.6 0.8 11.1 6.8 8.7 0.9 11.5 6.5 156 5 159 165 2.1 0 2.3 1.8 04/20/2006 16:00:00 10.1 1.2 13.3 6.8 10.1 1.2 13 7.2 10.1 1.1 13.3 8 151 3 145 165 2.3 0 2.6 2.1 04/20/2006 16:10:00 12.5 1.2 16.1 9.5 12.5 1.2 15.6 9.1 12.4 1.3 16.1 8.8 152 6 151 165 1.4 0.5 2.3 0.7 04/20/2006 16:20:00 9.9 0.8 12.2 7.6 9.8 0.8 11.8 7.6 9.7 0.9 12.6 7.6 152 5 151 165 0.6 0 0.9 0.4 04/20/2006 16:30:00 9.5 0.9 11.8 7.6 9.5 0.8 12.2 8 9.3 1.1 11.8 6.5 149 5 144 165 0.8 0 1.1 0.7 04/20/2006 16:40:00 8.2 1.3 11.1 5.3 8.2 1.3 11.1 5.3 8.2 1.4 11.1 4.9 155 5 150 165 0.6 0 0.9 0.4 04/20/2006 16:50:00 7 0.6 8.4 5.3 7 0.5 8.4 5.3 7 0.6 8.4 5.3 150 7 153 165 0.8 0 0.9 0.4 04/20/2006 17:00:00 7.8 2.2 13.3 4.9 7.8 2.2 13.3 4.9 7.8 2.1 14.9 4.9 147 6 137 165 0.9 0 1.4 0.9 04/20/2006 17:10:00 10.5 0.6 12.2 9.1 10.5 0.6 12.2 9.1 10.4 0.8 12.6 6.8 148 4 147 165 1.1 0 1.4 0.9 04/20/2006 17:20:00 10.7 0.6 12.2 9.1 10.8 0.6 12.6 8.8 10.7 0.8 12.6 8.8 147 5 146 165 1.2 0 1.6 1.1 04/20/2006 17:30:00 11.6 1 13.3 9.1 11.6 0.9 13.3 8.8 11.5 1.1 13.7 8.4 149 4 148 165 1.4 0 1.6 1.4 04/20/2006 17:40:00 12.7 0.8 14.1 10.7 12.8 0.8 14.1 10.7 12.7 0.9 14.9 9.5 145 3 144 165 1.3 0 1.6 0.9 04/20/2006 17:50:00 11.1 0.8 13 9.5 11.1 0.8 13 9.1 11.2 0.8 13.3 9.1 150 3 145 165 1.2 0.1 1.6 0.9 04/20/2006 18:00:00 10.4 1.3 15.6 8.4 10.4 1.3 15.3 8.4 10.4 1.3 15.6 8 148 4 142 165 1.4 0 1.6 1.4 04/20/2006 18:10:00 12.4 1.1 15.6 10.3 12.6 1 16.1 10.3 12.6 1.1 16.8 9.9 155 5 148 165 1.1 0.1 1.4 0.9 04/20/2006 18:20:00 10.5 0.6 12.6 8.8 10.6 0.7 12.6 8.8 10.6 0.7 12.6 8.4 149 5 151 165 0.9 0 1.1 0.9 04/20/2006 18:30:00 12.2 0.8 13.7 9.5 12.2 0.8 13.7 9.5 12.3 1 14.1 9.1 146 4 148 165 1.1 0 1.4 0.9 04/20/2006 18:40:00 12.4 0.7 14.1 10.3 12.4 0.7 14.1 10.3 12.5 1 14.9 9.9 147 4 147 165 1.2 0 1.4 1.1 04/20/2006 18:50:00 13.2 1 14.9 10.3 13.2 1 14.9 10.3 13.5 1 15.6 9.1 149 3 153 165 1.1 0 1.4 0.9 04/20/2006 19:00:00 12.8 0.8 14.5 10.7 12.8 0.7 14.1 10.7 13 0.9 14.9 10.7 150 3 151 165 1.1 0 1.4 0.9 04/20/2006 19:10:00 12.1 0.7 13.7 9.5 12.2 0.7 13.7 9.5 12.1 0.8 13.7 8.4 145 5 149 165 1.1 0 1.4 0.9 04/20/2006 19:20:00 12.6 0.7 14.5 10.7 12.7 0.7 14.9 10.7 12.7 0.7 14.9 10.7 144 5 145 165 1.3 0 1.6 1.1 04/20/2006 19:30:00 12.7 1 14.9 10.3 12.8 1 14.9 10.7 12.8 1.1 15.3 9.9 145 4 146 165 1.2 0 1.4 1.1 04/20/2006 19:40:00 12.7 1 15.6 10.3 12.9 0.9 15.3 10.3 12.7 0.9 15.3 10.3 142 2 142 165 1.4 0 1.6 1.4 04/20/2006 19:50:00 12 1.1 14.9 9.1 12.2 1.1 15.3 9.5 12.2 1 14.9 9.5 142 0 142 165 1.3 0 1.4 1.4 04/20/2006 20:00:00 12.4 1 14.5 9.5 12.5 0.9 15.3 9.5 12.5 1 15.3 8.8 142 0 142 165 1.4 0 1.6 1.1 04/20/2006 20:10:00 13 1.3 15.6 10.3 13.2 1.3 15.6 10.3 13.1 1.5 15.6 9.5 142 0 142 165 1.2 0 1.4 0.9 04/20/2006 20:20:00 11.5 1.4 16.1 9.1 11.8 1.3 16.1 9.5 11.6 1.4 16.8 8.4 142 0 142 165 1.3 0.1 1.6 0.9 04/20/2006 20:30:00 13.1 1.1 15.6 10.3 13.2 1.1 15.6 10.3 13.1 1.3 15.6 8.8 142 0 142 165 1.4 0 1.6 1.4 04/20/2006 20:40:00 12.1 1.2 15.3 9.5 12.4 1.2 15.6 9.5 12.4 1.3 15.6 8 142 0 142 165 1.4 0 1.6 1.4 04/20/2006 20:50:00 14 1.5 16.8 10.3 14.2 1.4 16.8 10.7 14.1 1.5 17.6 10.3 142 0 142 165 1.5 0 1.6 1.4 04/20/2006 21:00:00 14.3 1 16.4 11.1 14.3 1 16.8 11.5 14.3 1.1 16.4 10.3 142 0 142 165 1.5 0 1.6 1.4 04/20/2006 21:10:00 14.6 1.2 18.3 11.5 14.7 1.1 18.3 11.8 14.8 1.1 18.3 12.2 142 0 142 165 1.5 0 1.6 1.4 04/20/2006 21:20:00 13.4 1.3 16.1 9.5 13.5 1.4 16.1 9.9 13.6 1.5 16.4 8.4 142 0 142 165 1.5 0 1.6 1.4 04/20/2006 21:30:00 13.3 1.2 16.8 10.3 13.3 1.2 16.1 10.3 13.3 1.4 16.8 9.9 142 0 142 165 1.6 0 1.8 1.4 04/20/2006 21:40:00 13.5 1.1 15.6 9.9 13.5 1 15.6 10.7 13.4 1.2 16.8 10.3 142 0 142 165 1.7 0 1.8 1.4 04/20/2006 21:50:00 13.6 1.2 16.1 9.5 13.6 1.2 16.1 9.1 13.5 1.2 15.6 9.1 142 0 142 165 1.7 0 1.8 1.4 04/20/2006 22:00:00 14.1 1.1 16.1 9.5 13.9 1.1 16.1 9.5 13.9 1.2 16.4 10.3 142 0 142 165 1.7 0 1.8 1.6 04/20/2006 22:10:00 13.3 1.2 16.8 10.3 13.4 1.2 16.4 9.9 13.1 1.3 16.1 9.5 142 0 142 165 1.7 0 1.8 1.6 04/20/2006 22:20:00 14 1 16.8 11.1 13.9 1 16.8 11.5 13.7 1 15.6 11.1 142 0 142 165 1.7 0 1.8 1.6 04/20/2006 22:30:00 13.4 1.3 16.1 9.1 13.4 1.4 16.1 8.8 13.2 1.6 16.1 9.1 142 0 142 165 1.7 0 1.8 1.4 04/20/2006 22:40:00 13.3 1.1 15.6 8.4 13.3 1.1 16.1 8.8 12.9 1.2 16.4 7.6 142 0 142 165 1.7 0 1.8 1.6 04/20/2006 22:50:00 13.2 1.2 16.4 9.9 13.3 1.2 16.1 9.9 13.2 1.3 16.1 8.4 142 0 142 165 1.7 0 1.8 1.6 04/20/2006 23:00:00 12.8 1.1 15.3 10.3 12.9 1.2 15.6 9.9 12.5 1.3 15.6 9.1 142 0 142 165 1.7 0 1.8 1.6 04/20/2006 23:10:00 13 1.2 16.8 9.1 13 1.2 16.8 8.8 12.9 1.3 16.4 9.1 142 0 142 165 1.7 0 1.8 1.6 04/20/2006 23:20:00 12.3 1 14.5 9.9 12.3 1.1 14.5 9.9 12.5 1.1 16.1 9.5 142 0 142 165 1.7 0 1.8 1.6 04/20/2006 23:30:00 12.2 1 14.5 8.8 12.1 1.1 14.5 8.8 12.3 1.2 14.9 9.1 142 0 142 165 1.8 0 1.8 1.6 04/20/2006 23:40:00 12.2 1 14.9 9.5 12.2 1 14.9 9.1 12.5 1.1 16.1 9.5 142 0 142 165 1.8 0 1.8 1.6 04/20/2006 23:50:00 12.8 1 15.3 9.9 12.8 1 15.3 9.9 13.2 1.1 15.6 10.3 142 0 142 165 1.8 0 1.8 1.6 04/21/2006 00:00:00 14.1 1 16.8 11.8 14.2 1 17.2 11.8 14.7 1.1 17.2 11.1 142 0 142 165 1.8 0 1.8 1.6 04/21/2006 00:10:00 13 1.2 16.4 9.5 13.1 1.2 16.4 9.5 13.4 1.3 17.2 9.9 142 0 142 165 1.9 0 1.8 1.8 04/21/2006 00:20:00 14.3 1.7 17.9 9.5 14.4 1.7 17.9 9.9 14.6 2 18.3 9.1 142 0 142 165 1.9 0 2.1 1.6 04/21/2006 00:30:00 14.5 1.5 17.9 11.1 14.6 1.5 17.9 11.1 14.9 1.9 19.1 9.9 142 0 143 165 2 0 2.3 1.8 04/21/2006 00:40:00 14.6 1.3 17.6 11.1 14.9 1.3 17.6 11.5 15.2 1.5 18.3 10.7 144 1 145 165 2.2 0 2.3 1.8 04/21/2006 00:50:00 13.9 2.6 18.3 9.1 13.5 2.6 17.6 9.5 16 1.7 20.2 10.3 144 6 140 165 2.3 0.1 2.6 1.8 04/21/2006 01:00:00 15.9 2.6 20.6 8.8 10.2 1.7 17.2 9.1 16.5 1.6 21 12.2 141 7 141 165 2.4 0.2 2.6 1.8 04/21/2006 01:10:00 17.1 1.4 20.2 12.6 17.1 1.4 20.2 13 17 1.7 21 11.5 139 5 145 165 2.7 0 2.8 2.3 04/21/2006 01:20:00 15.8 1.5 18.7 9.5 15.7 1.5 18.7 9.9 15.6 1.8 19.5 10.3 140 7 138 165 2.9 0 3 2.6 04/21/2006 01:30:00 15.5 1.4 19.5 10.7 15.5 1.4 19.1 11.1 15.1 1.5 19.9 11.1 138 7 150 165 3 0 3.3 2.8 04/21/2006 01:40:00 15 1.2 18.7 11.8 15 1.2 18.3 11.1 14.7 1.3 17.9 11.1 140 6 147 165 3.3 0 3.5 3 04/21/2006 01:50:00 13.3 1.2 16.1 10.3 13.3 1.2 16.4 9.9 13.1 1.1 15.6 9.9 145 5 151 165 3.5 0 3.5 3.3 04/21/2006 02:00:00 10.7 1.1 13 8 10.5 1.1 13 8 10.4 1.2 12.6 7.2 156 11 153 165 3.5 0 3.5 3.5 04/21/2006 02:10:00 9.1 0.5 10.7 7.6 8.9 0.5 10.3 7.6 9.2 0.6 10.3 6.8 165 7 164 165 3.3 0 3.5 3 04/21/2006 02:20:00 9.2 0.6 11.1 7.6 8.9 0.6 10.7 7.6 9.2 0.6 11.1 8 160 9 157 165 3 0 3.3 2.8 04/21/2006 02:30:00 8.2 0.7 10.3 6.5 8 0.6 9.9 6.5 8.4 0.6 9.9 5.7 163 11 165 165 2.9 0 3 2.6 04/21/2006 02:40:00 7.4 1.1 11.1 5.3 7.1 1 11.1 5.3 7.4 0.8 9.5 5.7 167 8 165 165 2.7 0 2.8 2.6 04/21/2006 02:50:00 7.1 0.9 9.9 4.9 6.8 0.8 9.1 4.9 7.1 0.8 9.5 5.3 169 8 171 165 2.7 0 2.8 2.6 04/21/2006 03:00:00 9.5 1.2 12.2 7.2 9.2 1.2 11.8 6.8 9.4 1.2 12.2 7.6 166 11 165 165 2.7 0 2.8 2.6 04/21/2006 03:10:00 10.7 1 13.3 8.8 10.4 1 13 8.4 10.9 1 13 8.8 166 12 165 165 2.6 0.2 2.8 2.3 04/21/2006 03:20:00 7.7 1.2 9.9 5.3 7.4 1.1 9.5 4.9 7.8 1.2 10.3 5.3 173 6 163 165 2.3 0 2.6 2.3 04/21/2006 03:30:00 5.5 0.3 6.5 4.6 5.2 0.3 6.1 4.2 5.7 0.3 6.5 4.9 168 12 164 165 2.3 0 2.3 2.1 04/21/2006 03:40:00 4.8 0.7 6.5 3.4 4.5 0.6 6.1 3.4 4.8 0.6 6.5 3.8 165 9 164 165 2.3 0 2.6 2.1 04/21/2006 03:50:00 5.4 0.6 6.8 3.8 5.2 0.6 6.5 3.8 5.3 0.6 6.8 3.8 161 13 156 165 2.3 0 2.6 2.3 04/21/2006 04:00:00 6.3 0.7 8.4 4.2 6.1 0.7 8 4.2 6.4 0.6 8 4.9 157 14 138 165 2.5 0 2.8 2.3 04/21/2006 04:10:00 5.4 0.7 7.6 3.8 5.3 0.7 7.2 3.8 5.5 0.6 6.8 4.6 161 7 153 165 2.6 0 2.8 2.6 04/21/2006 04:20:00 6.4 1.1 8.8 4.6 6.3 1 8.4 4.6 6.6 1.1 9.1 4.6 157 4 149 165 2.6 0 2.8 2.6 04/21/2006 04:30:00 8.7 1 11.8 6.1 8.4 1 11.1 5.7 8.8 0.9 11.8 6.5 164 13 160 165 2.5 0.1 2.8 2.3 04/21/2006 04:40:00 8.5 1 11.5 6.5 8.2 1 11.1 6.5 8.5 1 11.5 6.5 170 6 167 165 2.3 0 2.6 2.3 04/21/2006 04:50:00 7.4 0.9 9.5 5.7 7.2 0.9 9.1 5.3 7.5 0.9 9.5 5.7 169 12 163 165 2.3 0 2.6 2.3 04/21/2006 05:00:00 7.5 0.4 8.8 6.5 7.3 0.4 8.8 6.1 7.7 0.5 8.8 6.5 166 13 165 165 2.3 0 2.6 2.1 04/21/2006 05:10:00 6.7 0.8 8.8 5.3 6.4 0.8 8.4 4.9 6.8 0.8 8.8 5.3 168 6 165 165 2.3 0 2.3 2.1 04/21/2006 05:20:00 6.6 0.6 7.6 4.9 6.3 0.5 7.2 4.9 6.7 0.6 8 4.9 172 5 166 165 2.3 0 2.3 2.1 04/21/2006 05:30:00 5.4 0.6 6.8 3.8 5.2 0.6 6.5 3.8 5.4 0.6 6.8 3.8 179 6 174 165 2.3 0 2.3 2.1 04/21/2006 05:40:00 6.1 0.8 7.6 4.2 5.9 0.7 7.6 3.8 6.2 0.8 8 4.2 176 5 173 165 2.1 0 2.3 2.1 04/21/2006 05:50:00 2.7 1.2 5.3 0.4 2.7 1.2 5.3 0.4 2.7 1.1 4.9 0.4 232 39 212 165 2.1 0 2.3 2.1 04/21/2006 06:00:00 3.4 1.1 6.5 0.4 3.4 1.1 6.5 0.4 3.4 1 6.1 0.4 213 13 218 165 2.1 0 2.3 1.8 04/21/2006 06:10:00 5.2 0.8 6.8 2.6 5.2 0.8 7.2 2.6 5.2 0.9 7.2 2.3 203 10 204 165 2 0 2.3 1.8 04/21/2006 06:20:00 4.7 0.8 6.5 2.6 4.7 0.8 6.5 2.6 4.7 0.8 6.8 2.6 199 7 205 165 1.9 0 2.1 1.8 04/21/2006 06:30:00 5.1 0.8 6.8 3 5.2 0.8 7.2 3 5.1 0.8 6.8 3 213 9 219 165 2 0 2.3 1.8 04/21/2006 06:40:00 4.4 0.8 6.8 2.6 4.3 0.8 6.8 3 4.6 0.8 7.6 3.4 196 8 185 165 2.1 0 2.3 1.8 04/21/2006 06:50:00 6.3 0.8 8.4 4.6 6.3 0.8 8.4 4.6 6.5 1 9.1 4.6 192 6 194 165 2.1 0 2.3 1.8 04/21/2006 07:00:00 7.6 0.8 9.1 4.2 7.7 0.8 9.5 4.6 7.6 1 9.5 4.6 198 7 205 165 2 0 2.3 1.8 04/21/2006 07:10:00 6.1 0.9 8.8 3.8 6.2 0.9 8.8 4.2 6.2 1 9.1 4.2 195 6 201 165 2 0 2.1 1.8 04/21/2006 07:20:00 7.3 1.3 9.5 4.9 7.2 1.3 9.5 4.6 7.2 1.5 10.3 4.2 184 8 197 165 2 0 2.3 1.8 04/21/2006 07:30:00 7 0.8 9.1 4.6 7 0.8 8.8 4.2 7 0.7 9.5 4.9 185 9 187 165 2.2 0 2.3 2.1 04/21/2006 07:40:00 6.4 1 9.1 3.4 6.3 1 8.4 3 6.4 0.8 8.8 3.8 183 11 162 165 2.4 0 2.6 2.3 04/21/2006 07:50:00 5.7 0.7 7.6 3.8 5.7 0.7 7.6 3.8 6 0.7 7.6 3.8 178 12 178 165 2.6 0 2.8 2.3 04/21/2006 08:00:00 6.6 0.8 8.4 3.8 6.5 0.8 8.4 3.8 6.9 0.8 8.8 4.2 180 9 180 165 3 0.1 3.3 2.6 04/21/2006 08:10:00 6.4 1.2 9.1 2.6 6.3 1.2 9.1 2.3 6.7 1.1 9.5 3.8 184 13 187 165 3.5 0.1 3.8 3.3 04/21/2006 08:20:00 7.2 1.3 10.7 4.2 7.2 1.3 10.7 3.8 7.2 1.2 10.3 4.6 192 10 194 165 3.4 0 3.5 3.3 04/21/2006 08:30:00 6.8 0.9 8.8 4.2 6.6 0.9 8.4 3.8 7.1 1 9.1 4.6 183 10 173 165 3.2 0.1 3.5 2.8 04/21/2006 08:40:00 6.8 1 8.4 4.2 6.5 1 8.8 3.8 6.9 1 9.1 4.2 180 12 192 165 3.3 0.1 3.5 3 04/21/2006 08:50:00 6.6 1 9.1 3.8 6.5 0.9 9.1 3.8 6.6 0.9 9.9 3.8 183 11 190 165 4 0.2 4.5 3.5 04/21/2006 09:00:00 8.4 1.3 11.5 4.9 8.2 1.3 11.1 4.9 8.6 1.2 12.2 6.1 182 10 178 165 4.1 0.1 4.5 3.5 04/21/2006 09:10:00 9.8 0.8 11.8 7.6 9.4 0.8 11.5 7.2 9.9 0.9 12.2 7.6 180 7 181 165 3.8 0 4 3.3 04/21/2006 09:20:00 8.8 1 11.1 5.3 8.6 1 11.1 5.3 9 1 11.8 6.5 183 9 182 165 4.1 0.1 4.5 3.8 04/21/2006 09:30:00 7.7 1 10.7 4.9 7.5 1.1 10.7 4.6 8 1.1 10.7 4.6 181 11 196 165 4.4 0 4.8 3.8 04/21/2006 09:40:00 6.9 1.2 10.3 3.8 6.9 1.2 10.3 3.8 7.1 1.1 9.9 3.4 190 12 189 165 4.8 0.2 5.2 4.3 04/21/2006 09:50:00 7.3 1.2 9.9 3.8 7.2 1.1 9.5 3.8 7.3 1.1 9.9 4.9 182 15 213 165 4.9 0 5.2 4.5 04/21/2006 10:00:00 8.3 1.7 12.6 4.9 8.1 1.7 12.2 4.6 8.5 1.7 13 5.3 180 12 165 165 5.2 0.3 5.7 4.5 04/21/2006 10:10:00 10.6 1.3 13.3 6.5 10.2 1.2 13 6.1 11 1.3 14.1 6.5 175 7 174 165 4.3 0.1 4.5 3.8 04/21/2006 10:20:00 10.8 0.6 12.2 8.8 10.4 0.6 11.8 8.8 11.1 0.7 13.3 9.1 174 6 171 165 4.6 0.3 5.2 3.8 04/21/2006 10:30:00 9.4 1 11.5 6.8 9 1 11.5 6.5 9.6 1.1 11.8 6.5 176 6 178 165 5.1 0.1 5.5 4.8 04/21/2006 10:40:00 8.4 1 10.7 5.7 8.2 1 10.7 5.3 8.7 0.9 11.1 5.7 177 9 180 165 5.2 0.1 5.5 4.8 04/21/2006 10:50:00 8.5 1 11.8 5.7 8.3 1.1 11.1 5.3 8.7 1.1 11.1 6.1 186 7 192 165 5.2 0 5.5 5 04/21/2006 11:00:00 8.2 1.1 10.7 4.9 8 1.1 10.7 5.3 8.4 1.1 11.5 5.3 178 10 182 165 5.4 0 5.7 5.2 04/21/2006 11:10:00 7.8 1.1 11.1 4.2 7.5 1.1 11.1 3.8 8 1.1 11.5 4.9 179 10 192 165 5.1 0.1 5.5 4.8 04/21/2006 11:20:00 8.3 0.8 10.3 5.7 8.1 0.9 10.3 5.3 8.6 0.9 10.7 6.1 175 13 178 165 5.6 0.1 6 5.5 04/21/2006 11:30:00 8.1 1.1 10.7 4.9 7.9 1.1 10.3 4.6 8.4 1 11.1 5.7 179 11 180 165 5.8 0.1 6 5.2 04/21/2006 11:40:00 9.4 1.1 13.3 6.1 9.2 1.1 13 5.7 9.8 1.2 13.7 6.1 178 9 178 165 5.8 0.1 6 5.5 04/21/2006 11:50:00 9.4 1 11.8 6.5 9.1 1 11.5 6.5 9.7 1.1 13 6.5 176 13 182 165 5.7 0.1 6 5.5 04/21/2006 12:00:00 8.2 1.1 10.7 5.3 8 1 10.3 4.9 8.3 1 11.1 5.7 180 9 163 165 5.8 0.1 6.2 5.2 04/21/2006 12:10:00 7.3 1 10.3 4.6 7.2 1 9.9 4.6 7.6 1.2 10.7 5.3 190 13 162 165 5.7 0.4 6.5 5 04/21/2006 12:20:00 6.8 0.9 9.1 4.2 6.6 0.9 8.8 3.8 7.1 0.9 9.1 4.9 169 13 166 165 5.9 0.2 6.2 5.5 04/21/2006 12:30:00 7 0.8 9.1 5.3 6.8 0.8 8.8 4.9 7.2 0.8 9.5 4.9 168 13 165 165 6.1 0.3 6.7 5.5 04/21/2006 12:40:00 7.6 0.8 9.5 5.7 7.4 0.9 9.5 5.3 7.8 0.9 9.9 5.3 167 9 175 165 5.2 0.2 5.7 4.5 04/21/2006 12:50:00 9.9 0.7 11.8 8 9.6 0.7 11.8 8 10.2 0.8 12.2 8.4 168 13 175 165 5.1 0.2 5.7 4.3 04/21/2006 13:00:00 10.2 0.7 11.8 8 9.9 0.7 11.5 8 10.5 0.7 11.8 8.4 168 17 169 165 4.9 0.2 5.5 4.3 04/21/2006 13:10:00 10.5 0.8 12.6 8 10.2 0.8 12.6 7.6 10.9 0.9 13.3 8 172 5 182 165 5 0.3 5.7 4.5 04/21/2006 13:20:00 10.5 0.7 12.2 8.8 10.2 0.7 12.2 8.4 10.7 0.8 13.3 8.4 171 6 177 165 5.1 0.2 5.7 4.5 04/21/2006 13:30:00 10.4 1.1 12.2 7.6 10.1 1.1 12.2 7.6 10.5 1.1 13.3 7.6 170 12 169 165 5.3 0.2 5.7 4.5 04/21/2006 13:40:00 11.4 1 13.3 8 11.1 1 13 7.6 11.6 1.1 14.1 8 166 12 165 165 4.5 0.2 5.2 4.3 04/21/2006 13:50:00 10.4 1 12.2 6.8 10.1 1 11.8 6.8 10.7 1.1 12.6 8 166 13 164 165 5 0.1 5.5 4.5 04/21/2006 14:00:00 10.9 0.8 12.6 8.8 10.5 0.7 11.8 8.8 11.2 0.9 13 8 167 19 165 165 4.3 0.2 5 4.3 04/21/2006 14:10:00 10.1 0.7 11.8 8 9.7 0.7 11.5 8 10.4 0.7 12.2 8.4 166 14 165 165 4.9 0.2 5.2 4.3 04/21/2006 14:20:00 8.9 0.6 10.7 7.2 8.6 0.6 10.3 7.2 9.2 0.6 10.3 7.2 168 24 157 165 4.9 0.2 5.5 4.3 04/21/2006 14:30:00 8 1 11.5 5.3 7.7 0.9 11.5 4.9 8.3 0.9 10.3 5.7 172 10 173 165 4.8 0.3 5.5 4.3 04/21/2006 14:40:00 7.1 1 9.9 4.6 6.9 0.9 9.5 4.6 7.4 1 10.3 4.6 175 10 177 165 5.3 0.1 5.7 5 04/21/2006 14:50:00 6.9 0.9 10.3 4.9 7 1 9.9 4.9 7 1 9.9 4.9 198 12 195 165 5.1 0.2 5.7 4.8 04/21/2006 15:00:00 6.5 0.8 8.8 4.2 6.5 0.8 8.8 4.6 6.6 0.8 8.4 4.2 200 10 204 165 4.5 0 5 4.5 04/21/2006 15:10:00 7.1 1 9.9 4.9 7 1 9.9 4.6 7.2 1 9.5 4.2 184 9 178 165 4.6 0.3 5.2 4.3 04/21/2006 15:20:00 9.4 1 11.1 5.3 9.1 0.9 10.7 5.3 9.7 1 11.8 6.1 174 9 176 165 4.1 0.5 5.2 3.3 04/21/2006 15:30:00 8.1 0.7 9.9 6.5 7.8 0.7 9.5 6.5 8.4 0.8 10.7 6.8 176 7 165 165 3.5 0.1 3.8 3.3 04/21/2006 15:40:00 7.3 0.5 8.4 6.1 6.9 0.5 8.4 5.7 7.5 0.5 9.1 6.1 176 6 164 165 3.5 0 3.8 3.5 04/21/2006 15:50:00 8.1 0.5 9.5 6.5 7.8 0.5 8.8 6.5 8.4 0.6 9.9 6.8 171 5 169 165 3.9 0.1 4.3 3.5 04/21/2006 16:00:00 7.4 0.5 8.4 6.5 7.1 0.4 8.4 6.1 7.7 0.5 8.8 6.5 170 9 170 165 3.6 0 3.8 3.5 04/21/2006 16:10:00 7.8 0.6 9.1 5.7 7.5 0.6 8.8 5.7 8.1 0.7 9.5 6.1 167 17 165 165 3.8 0 4 3.5 04/21/2006 16:20:00 8 0.6 9.1 6.1 7.7 0.5 8.8 6.1 8.2 0.7 9.5 6.1 168 6 169 165 3.8 0 4 3.5 04/21/2006 16:30:00 8.4 0.6 9.9 6.5 8.1 0.6 9.5 6.8 8.7 0.6 10.3 7.2 168 11 164 165 4.1 0.1 4.5 3.8 04/21/2006 16:40:00 8.9 0.4 9.9 7.2 8.6 0.4 9.9 6.8 9.2 0.4 10.3 8 170 13 171 165 4.4 0 4.8 4.3 04/21/2006 16:50:00 8.5 0.5 10.3 7.2 8.2 0.4 9.9 7.2 8.8 0.5 10.3 6.8 167 4 165 165 4.1 0 4.3 4 04/21/2006 17:00:00 8.3 0.7 9.5 6.5 8 0.6 9.5 6.5 8.5 0.8 9.9 6.5 170 13 227 165 3.9 0 4.3 3.5 04/21/2006 17:10:00 8.4 0.5 9.5 6.8 8.1 0.5 9.1 6.8 8.7 0.6 9.9 6.8 170 13 164 165 3.7 0.1 4 3.5 04/21/2006 17:20:00 9.1 0.4 10.3 7.6 8.8 0.4 9.5 7.2 9.4 0.5 10.7 7.6 168 8 165 165 3.9 0 4.3 3.5 04/21/2006 17:30:00 9.5 0.6 10.7 7.6 9.2 0.5 10.3 7.6 9.8 0.7 11.1 7.6 169 11 165 165 3.5 0 3.8 3.3 04/21/2006 17:40:00 9.5 0.5 11.1 7.6 9.2 0.5 10.3 7.2 9.8 0.6 11.1 8 168 6 163 165 3.5 0.1 4 3.3 04/21/2006 17:50:00 9.3 0.5 10.3 8 9 0.4 9.9 8 9.6 0.5 10.7 8.4 167 4 179 165 3.8 0 4 3.5 04/21/2006 18:00:00 9.8 0.5 11.1 8.4 9.5 0.5 10.7 8.4 10.1 0.6 11.1 8.4 167 17 165 165 3.5 0 3.8 3.3 04/21/2006 18:10:00 8.6 0.5 9.9 6.8 8.4 0.5 9.9 6.8 8.8 0.6 9.9 7.2 167 18 166 165 3.5 0 3.5 3.3 04/21/2006 18:20:00 8.1 0.4 8.8 6.8 7.8 0.4 8.8 6.5 8.2 0.5 9.1 6.5 164 3 165 165 3.3 0 3.5 3 04/21/2006 18:30:00 8.1 0.4 9.1 7.2 7.9 0.3 8.8 7.2 8.3 0.3 9.1 7.2 165 12 165 165 3.4 0 3.5 3 04/21/2006 18:40:00 7.6 0.4 9.1 6.5 7.3 0.4 8.8 6.5 7.8 0.4 9.1 6.8 168 13 161 165 3.5 0 3.5 3.3 04/21/2006 18:50:00 7.6 0.4 8.4 6.1 7.3 0.4 8 6.1 7.7 0.4 8.4 6.5 168 8 174 165 3.1 0.1 3.5 2.8 04/21/2006 19:00:00 7.3 0.5 9.1 5.7 7.2 0.5 8.8 5.7 7.4 0.5 8.8 5.7 173 7 178 165 3 0 3 2.8 04/21/2006 19:10:00 7.2 0.5 8.4 5.7 7 0.4 8 5.7 7.3 0.6 8.4 5.3 172 4 172 165 3 0 3.3 2.8 04/21/2006 19:20:00 6.1 0.5 7.2 4.9 5.9 0.4 6.8 4.9 6.2 0.5 7.6 4.6 173 9 172 165 2.9 0 3 2.8 04/21/2006 19:30:00 5.6 0.5 6.8 4.6 5.5 0.4 6.8 4.6 5.8 0.5 7.2 4.6 168 10 165 165 2.8 0 2.8 2.6 04/21/2006 19:40:00 5.7 0.5 6.8 4.2 5.6 0.4 6.5 4.2 6 0.5 7.2 4.9 172 10 178 165 2.7 0 2.8 2.6 04/21/2006 19:50:00 4.9 0.6 6.5 3 4.8 0.5 6.1 3.4 5.1 0.5 6.5 3.4 174 6 180 165 2.6 0.1 2.8 2.3 04/21/2006 20:00:00 4.1 0.5 5.3 3 4 0.5 5.3 2.6 4.4 0.6 6.1 3.4 172 7 168 165 2.4 0 2.6 2.3 04/21/2006 20:10:00 3.9 0.4 4.9 3 3.8 0.4 4.6 2.6 4.1 0.4 4.9 3 173 6 177 165 2.3 0 2.6 2.1 04/21/2006 20:20:00 3.9 0.4 5.3 3 3.8 0.4 4.9 2.6 4.1 0.3 4.9 3 174 6 181 165 2.2 0 2.3 1.8 04/21/2006 20:30:00 4.9 0.5 6.5 3.4 4.7 0.5 6.1 3.4 5 0.5 6.1 3 173 9 178 165 2.1 0 2.3 1.8 04/21/2006 20:40:00 5.6 0.5 6.8 4.2 5.5 0.4 6.8 4.2 5.7 0.5 6.8 4.2 170 9 165 165 1.9 0 2.1 1.8 04/21/2006 20:50:00 5.9 0.5 7.2 4.6 5.7 0.5 7.2 4.6 5.9 0.6 7.2 4.6 169 6 185 165 1.8 0 2.1 1.6 04/21/2006 21:00:00 5.4 0.6 6.8 3.8 5.2 0.6 6.5 3.8 5.6 0.7 7.2 4.2 173 7 160 165 1.8 0 1.8 1.6 04/21/2006 21:10:00 4.9 0.8 6.8 3 4.7 0.7 6.8 3 5.1 0.8 6.8 3.4 176 9 173 165 1.7 0 1.8 1.6 04/21/2006 21:20:00 4 0.6 5.3 2.6 4 0.6 4.9 2.6 4.3 0.5 5.7 3 180 7 187 165 1.7 0 1.8 1.6 04/21/2006 21:30:00 4 0.5 5.3 2.6 4 0.5 5.3 2.3 4.3 0.5 5.3 2.6 183 6 179 165 1.8 0 2.1 1.6 04/21/2006 21:40:00 4.3 0.5 5.7 2.6 4.2 0.5 5.3 3 4.5 0.5 5.7 3.4 180 6 177 165 1.8 0 1.8 1.6 04/21/2006 21:50:00 4.6 0.4 5.7 3.8 4.5 0.4 5.3 3.4 4.7 0.5 5.7 3.8 185 4 183 165 1.7 0 1.8 1.6 04/21/2006 22:00:00 4.5 0.4 5.7 3.8 4.4 0.4 5.3 3.4 4.8 0.4 5.7 3.8 182 4 182 165 1.6 0 1.8 1.4 04/21/2006 22:10:00 4.1 0.4 4.9 3 4.2 0.4 4.9 3 4.2 0.5 5.3 2.6 197 6 191 165 1.6 0 1.8 1.4 04/21/2006 22:20:00 3.2 0.6 4.6 1.9 3.3 0.6 4.6 1.9 3.3 0.5 4.6 2.3 208 7 204 165 1.5 0 1.6 1.4 04/21/2006 22:30:00 3.6 0.7 4.9 2.3 3.6 0.7 4.9 2.3 3.8 0.7 5.3 1.9 195 11 183 165 1.6 0 1.8 1.4 04/21/2006 22:40:00 4.5 0.5 5.7 3.4 4.4 0.5 5.3 3 4.7 0.5 6.1 3.8 177 6 179 165 1.7 0 1.8 1.4 04/21/2006 22:50:00 4.6 0.5 5.7 3.4 4.4 0.4 5.7 3.4 4.8 0.4 6.1 3 174 6 179 165 1.5 0 1.8 1.4 04/21/2006 23:00:00 4.3 0.5 5.3 3.4 4.1 0.5 5.3 3.4 4.5 0.5 5.7 3.4 172 6 173 165 1.4 0 1.6 1.4 04/21/2006 23:10:00 3.7 0.4 4.9 2.6 3.7 0.4 4.9 3 4.1 0.4 5.3 3 190 6 187 165 1.4 0 1.6 1.4 04/21/2006 23:20:00 3.6 0.9 5.3 1.9 3.6 0.8 4.9 1.9 3.8 0.9 5.7 1.9 185 6 186 165 1.4 0 1.6 1.1 04/21/2006 23:30:00 2.5 0.4 3.4 1.5 2.5 0.4 3.4 1.5 2.6 0.4 3.4 1.9 188 4 184 165 1.2 0 1.4 0.9 04/21/2006 23:40:00 1.9 0.3 2.6 1.1 1.9 0.3 2.6 1.1 2.2 0.3 3 1.5 185 4 183 165 1.4 0 1.4 1.1 04/21/2006 23:50:00 2.3 0.4 3.8 1.1 2.2 0.4 3.4 1.1 2.6 0.4 3.4 1.5 171 9 165 165 1.2 0 1.4 0.9 04/22/2006 00:00:00 2.7 0.3 3.4 1.9 2.6 0.3 3.4 1.5 2.9 0.4 3.8 1.9 173 7 167 165 1.2 0 1.4 0.9 04/22/2006 00:10:00 2.9 0.3 3.8 2.3 2.9 0.3 3.8 2.3 3.1 0.3 3.8 2.3 185 5 180 165 1.2 0 1.4 0.9 04/22/2006 00:20:00 3.6 0.3 4.2 3 3.5 0.3 4.2 3 3.8 0.3 4.6 3 177 2 177 165 1.2 0 1.4 1.1 04/22/2006 00:30:00 2.4 0.6 3.8 1.1 2.4 0.5 3.8 1.5 2.8 0.5 4.2 1.9 189 7 181 165 1.1 0 1.4 0.9 04/22/2006 00:40:00 1.6 0.4 3.4 0.7 1.6 0.4 3 0.7 2.1 0.3 3 1.5 185 10 189 165 1.1 0 1.4 0.9 04/22/2006 00:50:00 1.6 0.4 3 0.7 1.5 0.5 3 0.4 2 0.3 3 1.1 181 6 185 165 1.2 0 1.4 1.1 04/22/2006 01:00:00 0.9 0.4 1.9 0.4 0.7 0.4 1.9 0.4 1.4 0.3 2.3 0.4 195 15 178 165 1.2 0 1.4 0.9 04/22/2006 01:10:00 0.4 0.2 1.1 0.4 0.4 0.2 1.1 0.4 1 0.3 1.9 0.4 213 8 214 165 1.1 0 1.4 0.9 04/22/2006 01:20:00 0.5 0.2 1.1 0.4 0.4 0.1 1.1 0.4 1.2 0.3 1.5 0.4 169 36 181 165 0.9 0 1.1 0.9 04/22/2006 01:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.7 0.2 1.5 0.4 140 49 165 165 0.8 0 0.9 0.9 04/22/2006 01:40:00 1 0.4 1.9 0.4 0.9 0.5 1.9 0.4 1.3 0.5 2.3 0.4 176 14 180 165 0.9 0 1.1 0.9 04/22/2006 01:50:00 0.7 0.4 1.5 0.4 0.9 0.3 1.5 0.4 1.4 0.3 1.9 0.7 194 3 188 165 1.1 0 1.4 0.9 04/22/2006 02:00:00 0.4 0 0.4 0.4 0.4 0.1 1.1 0.4 1 0.2 1.5 0.4 202 0 165 165 1.1 0 1.4 0.9 04/22/2006 02:10:00 0.4 0.2 1.5 0.4 0.7 0.4 1.5 0.4 1.2 0.3 1.9 0.4 210 8 210 165 1.2 0 1.4 0.9 04/22/2006 02:20:00 0.4 0.3 1.5 0.4 0.5 0.3 1.5 0.4 1 0.4 1.9 0.4 206 7 207 165 1.1 0 1.4 0.9 04/22/2006 02:30:00 1.4 0.4 2.3 0.7 1.5 0.4 2.3 0.4 1.8 0.3 2.6 1.1 200 4 192 165 1.1 0 1.4 0.9 04/22/2006 02:40:00 1.7 0.3 2.3 0.7 1.8 0.4 2.6 0.7 2.2 0.3 2.6 1.5 175 5 189 165 1.1 0 1.4 0.9 04/22/2006 02:50:00 1.4 0.4 1.9 0.4 1.3 0.4 1.9 0.4 1.8 0.2 2.3 1.1 177 5 179 165 1 0 1.4 0.9 04/22/2006 03:00:00 0.9 0.5 1.9 0.4 0.8 0.4 1.9 0.4 1.3 0.3 1.9 0.7 183 2 184 165 1.1 0 1.4 0.9 04/22/2006 03:10:00 1.1 0.2 1.5 0.7 0.7 0.4 1.5 0.4 1.6 0.2 1.9 1.1 179 4 186 165 0.9 0 1.1 0.9 04/22/2006 03:20:00 1.5 0.2 1.9 1.1 1.4 0.2 1.9 0.7 2 0.2 2.3 1.5 166 9 165 165 0.8 0 1.1 0.9 04/22/2006 03:30:00 1.6 0.2 1.9 1.1 1.3 0.2 1.9 0.7 2 0.2 2.3 1.5 166 6 165 165 0.8 0 0.9 0.7 04/22/2006 03:40:00 1.1 0.3 1.9 0.7 0.6 0.3 1.5 0.4 1.5 0.2 1.9 1.1 168 3 169 165 0.8 0 0.9 0.9 04/22/2006 03:50:00 1.1 0.2 1.9 0.4 0.8 0.3 1.5 0.4 1.6 0.2 1.9 1.1 170 3 165 165 0.8 0 1.1 0.7 04/22/2006 04:00:00 0.5 0.2 1.1 0.4 0.4 0 0.4 0.4 1 0.3 1.5 0.4 172 0 172 165 0.9 0 1.1 0.9 04/22/2006 04:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.5 0.2 0.7 0.4 172 0 165 165 0.9 0 1.1 0.9 04/22/2006 04:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.8 0.3 1.1 0.4 164 8 165 165 0.7 0 0.9 0.7 04/22/2006 04:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 1 0.2 1.5 0.7 156 0 165 165 0.5 0 0.7 0.2 04/22/2006 04:40:00 0.5 0.2 1.5 0.4 0.4 0 0.4 0.4 1.2 0.2 1.9 0.7 156 1 157 165 0.3 0.1 0.7 0.2 04/22/2006 04:50:00 0.7 0.3 1.1 0.4 0.4 0 0.4 0.4 1.2 0.2 1.5 0.7 169 1 165 165 0.2 0 0.4 0.2 04/22/2006 05:00:00 0.4 0.2 1.1 0.4 0.4 0 0.4 0.4 1.2 0.3 1.9 0.4 171 3 170 165 0.3 0 0.7 0.2 04/22/2006 05:10:00 0.8 0.3 1.5 0.4 0.6 0.3 1.1 0.4 1.3 0.2 1.9 0.7 186 5 181 165 0.3 0 0.7 0.2 04/22/2006 05:20:00 0.4 0.1 0.7 0.4 0.4 0 0.4 0.4 0.8 0.3 1.5 0.4 178 2 183 165 0.4 0 0.7 0.2 04/22/2006 05:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.7 0.2 1.1 0.4 177 0 165 165 0.5 0 0.7 0.2 04/22/2006 05:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.5 0.2 1.1 0.4 177 0 165 165 0.5 0 0.7 0.4 04/22/2006 05:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.6 0.2 1.1 0.4 177 0 165 165 0.5 0 0.7 0.4 04/22/2006 06:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 1.3 0.2 1.9 0.7 193 11 165 165 0.5 0 0.7 0.2 04/22/2006 06:10:00 0.5 0.2 1.1 0.4 0.4 0 0.4 0.4 1.3 0.3 1.9 0.4 210 5 210 165 0.5 0 0.7 0.2 04/22/2006 06:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.6 0.3 1.5 0.4 214 0 165 165 0.7 0 0.9 0.7 04/22/2006 06:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.7 0.4 214 0 165 165 0.8 0 1.1 0.7 04/22/2006 06:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0.2 1.1 0.4 214 0 165 165 1.1 0 1.4 0.9 04/22/2006 06:50:00 0.4 0.2 1.1 0.4 0.4 0.2 1.5 0.4 0.8 0.3 1.9 0.4 271 17 278 165 1.1 0 1.4 0.9 04/22/2006 07:00:00 0.4 0.1 0.7 0.4 0.4 0.1 1.1 0.4 1.1 0.2 1.5 0.4 265 6 262 165 1.2 0 1.4 0.9 04/22/2006 07:10:00 0.4 0.1 0.7 0.4 0.4 0 0.4 0.4 0.8 0.4 1.5 0.4 256 5 262 165 1.4 0 1.6 1.4 04/22/2006 07:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0.2 1.1 0.4 252 0 165 165 1.8 0.1 2.3 1.4 04/22/2006 07:30:00 0.4 0.1 0.7 0.4 0.4 0 0.4 0.4 0.5 0.2 1.1 0.4 265 15 285 165 2.9 0.3 3.5 2.3 04/22/2006 07:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.6 0.2 1.1 0.4 285 0 165 165 3.4 0.2 3.8 3.3 04/22/2006 07:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 285 0 165 165 4 0.1 4.5 3.8 04/22/2006 08:00:00 0.4 0 0.7 0.4 0.4 0 0.4 0.4 0.4 0.1 1.1 0.4 235 24 223 165 4.7 0.2 5.2 4.3 04/22/2006 08:10:00 0.5 0.3 1.9 0.4 0.4 0.2 1.9 0.4 0.5 0.4 1.9 0.4 131 64 338 165 5.6 0.2 6 5 04/22/2006 08:20:00 0.9 0.5 2.3 0.4 0.7 0.5 1.9 0.4 0.9 0.5 2.3 0.4 168 32 170 165 5.1 0.1 5.5 4.5 04/22/2006 08:30:00 0.9 0.5 1.9 0.4 0.7 0.5 1.9 0.4 0.9 0.5 2.3 0.4 255 33 189 165 4.6 0.2 5.2 4.3 04/22/2006 08:40:00 1 0.5 2.3 0.4 0.8 0.5 2.3 0.4 1.2 0.5 2.6 0.4 236 33 165 165 4.1 0.1 4.5 3.5 04/22/2006 08:50:00 0.9 0.6 2.6 0.4 0.7 0.5 2.6 0.4 1 0.5 2.6 0.4 202 58 186 165 4.1 0 4.3 3.8 04/22/2006 09:00:00 2.5 0.6 4.2 0.7 2 0.7 3.8 0.4 2.5 0.6 3.8 1.1 147 23 221 165 3.7 0.4 4.3 2.8 04/22/2006 09:10:00 2.9 0.7 4.6 0.4 2.7 0.8 4.2 0.4 3 0.6 4.2 0.7 176 18 165 165 3 0.1 3.5 2.3 04/22/2006 09:20:00 2.2 0.5 3.8 0.4 1.9 0.6 3 0.4 2.2 0.6 3.8 0.7 183 20 175 165 4 0.4 4.8 3.3 04/22/2006 09:30:00 3 0.6 4.6 1.5 2.8 0.6 4.2 1.1 3.1 0.6 4.6 1.5 161 8 160 165 4.3 0 4.5 3.8 04/22/2006 09:40:00 3.5 0.9 6.1 1.5 3.1 1 6.1 1.1 3.5 0.8 5.7 1.5 154 13 165 165 4.1 0.1 4.8 3.8 04/22/2006 09:50:00 3.9 0.6 5.7 2.6 3.6 0.6 5.3 2.3 3.9 0.6 5.3 2.6 148 13 160 165 4.1 0.1 4.5 3.8 04/22/2006 10:00:00 3.5 0.7 5.3 1.9 3.2 0.7 5.3 1.5 3.6 0.7 5.7 1.9 149 17 144 165 3.8 0 4.3 3.3 04/22/2006 10:10:00 3.7 0.6 5.3 2.3 3.4 0.7 5.3 1.5 3.8 0.6 5.3 1.9 147 17 177 165 3.9 0.2 4.3 3 04/22/2006 10:20:00 3.8 0.5 5.3 2.3 3.5 0.6 5.3 1.9 4 0.5 5.3 2.6 155 12 151 165 3.9 0 4.3 3.5 04/22/2006 10:30:00 4.1 0.6 6.1 3 3.8 0.7 5.7 2.3 4.1 0.6 5.7 2.6 152 12 166 165 4.1 0.3 4.8 3.8 04/22/2006 10:40:00 4.4 0.8 7.2 2.3 4.2 0.9 6.5 2.3 4.4 0.8 6.5 2.3 147 15 135 165 4.6 0 4.8 4.3 04/22/2006 10:50:00 4 0.8 6.1 1.9 3.7 0.9 5.7 1.5 4 0.8 6.5 1.5 141 17 153 165 4.7 0 5 4.5 04/22/2006 11:00:00 3.6 0.8 5.7 1.9 3.3 0.9 5.7 1.5 3.7 0.8 5.7 1.9 141 16 160 165 4.6 0.1 5 4.3 04/22/2006 11:10:00 3.1 0.8 5.3 1.1 2.8 1 5.3 0.4 3.2 0.9 5.7 0.7 127 22 143 165 3.8 0.2 4.5 3.5 04/22/2006 11:20:00 2.1 0.9 3.8 0.4 1.6 0.9 3.4 0.4 2.1 0.9 3.8 0.4 156 26 150 165 3.5 0 3.8 3.3 04/22/2006 11:30:00 3 0.6 4.9 1.5 2.6 0.7 4.2 0.7 3 0.6 4.6 1.1 148 15 165 165 3.6 0.1 4 3.3 04/22/2006 11:40:00 2.4 0.5 3.4 0.7 1.8 0.7 3 0.4 2.3 0.5 3.4 1.1 153 18 180 165 3.3 0 3.5 2.8 04/22/2006 11:50:00 2.8 0.8 4.9 0.4 2.3 0.9 4.6 0.4 2.9 0.7 4.6 1.1 145 15 121 165 3.3 0 3.5 2.8 04/22/2006 12:00:00 2.7 0.4 3.8 1.9 2.2 0.5 3.8 1.1 2.7 0.5 3.8 1.5 148 8 139 165 3.2 0.2 3.8 2.8 04/22/2006 12:10:00 2.7 0.8 5.3 0.7 2.4 1 5.3 0.4 2.7 0.9 4.9 0.4 146 17 135 165 4.6 0.4 5.2 3.8 04/22/2006 12:20:00 3.9 0.8 6.5 1.9 3.8 0.8 5.7 1.9 4 0.7 6.1 2.3 149 13 158 165 5.1 0.2 5.5 4.5 04/22/2006 12:30:00 3.6 0.7 6.1 2.3 3.3 0.8 5.3 1.5 3.6 0.8 6.5 1.9 140 14 126 165 4.5 0.1 5 4.3 04/22/2006 12:40:00 3.7 0.8 6.1 2.3 3.3 0.9 5.7 1.5 3.6 0.8 5.7 1.1 142 12 145 165 4.6 0.1 5.2 4.5 04/22/2006 12:50:00 3.6 0.8 5.3 1.5 3.4 0.9 5.7 0.7 3.7 0.8 5.3 1.9 151 16 128 165 5.4 0.1 5.7 5 04/22/2006 13:00:00 3.2 0.9 5.3 0.4 2.9 1 4.9 0.4 3.1 0.9 4.9 0.4 146 22 164 165 5.6 0.2 6.5 5.2 04/22/2006 13:10:00 3.3 0.8 5.7 1.9 3.2 0.8 6.1 1.5 3.4 0.7 5.3 1.9 141 16 148 165 5.3 0.1 5.7 5 04/22/2006 13:20:00 3.5 0.7 5.7 2.3 3.3 0.8 5.7 1.9 3.5 0.7 5.3 1.9 154 15 131 165 5.6 0 5.7 5.2 04/22/2006 13:30:00 3.3 0.7 5.3 1.9 3.2 0.7 5.3 1.9 3.3 0.7 5.3 1.9 140 13 144 165 5.6 0.2 6.2 5.2 04/22/2006 13:40:00 3.9 1 6.1 1.9 3.8 1 6.5 1.5 3.7 0.8 6.1 1.9 143 17 153 165 6.1 0.2 6.7 5.7 04/22/2006 13:50:00 3.4 1 6.1 0.7 3.4 1 6.1 0.7 3.5 0.9 5.7 1.5 133 17 139 165 6.1 0.3 7 5.7 04/22/2006 14:00:00 5 0.8 7.6 3 4.9 0.8 7.6 3 5 0.7 6.8 3 138 17 116 165 5.7 0.4 6.5 5 04/22/2006 14:10:00 4.9 0.5 6.5 3.4 4.8 0.5 6.1 3.4 4.9 0.5 6.5 3.8 157 12 164 165 4.7 0.2 5.2 4.5 04/22/2006 14:20:00 6.4 0.9 8 4.2 6.3 0.9 8 4.6 6.5 0.9 8.4 4.6 162 12 163 165 4.3 0.3 5 3.5 04/22/2006 14:30:00 8.2 0.9 9.9 5.7 7.9 0.8 9.5 5.7 8.3 0.9 9.9 5.3 166 10 163 165 3.7 0.1 4 3.3 04/22/2006 14:40:00 7.6 0.7 9.5 5.7 7.4 0.7 9.5 5.7 7.7 0.7 9.5 5.3 159 8 166 165 3.3 0.1 3.5 2.8 04/22/2006 14:50:00 7 0.8 9.1 5.3 6.9 0.7 8.8 5.3 7.1 0.8 9.1 4.9 158 7 161 165 3.5 0.2 4.3 2.8 04/22/2006 15:00:00 6 0.7 7.6 4.2 6 0.7 8 4.2 6.3 0.7 8.4 4.2 151 10 154 165 4.1 0.1 4.5 3.5 04/22/2006 15:10:00 6.4 0.8 8.4 4.9 6.3 0.8 8 4.6 6.5 0.7 8.4 4.6 151 10 164 165 4.2 0.2 4.5 3.8 04/22/2006 15:20:00 6.6 0.7 8.8 4.9 6.5 0.7 8.8 4.6 6.8 0.7 8.4 4.2 155 6 145 165 4 0.1 4.5 3.5 04/22/2006 15:30:00 7.3 0.8 9.1 4.9 7.1 0.7 8.8 4.9 7.5 0.8 9.1 5.3 167 11 183 165 4.6 0.2 5 3.8 04/22/2006 15:40:00 8.5 0.6 9.9 6.5 8.3 0.6 10.3 6.5 8.8 0.7 10.3 6.8 169 6 169 165 5.2 0.2 5.7 4.5 04/22/2006 15:50:00 8 0.6 9.5 6.5 7.9 0.6 9.5 6.1 8.3 0.7 10.3 6.5 167 10 166 165 6 0.2 6.2 5.2 04/22/2006 16:00:00 7.3 0.7 9.1 5.7 7.1 0.7 9.5 5.3 7.5 0.7 9.1 6.1 170 12 165 165 6.1 0.2 6.5 5.7 04/22/2006 16:10:00 7.1 0.6 9.1 5.3 7 0.6 9.1 5.3 7.3 0.6 9.9 5.7 168 10 173 165 5.8 0.1 6.2 5.5 04/22/2006 16:20:00 6.9 1.1 9.1 3.4 6.7 1.1 9.5 3.4 7.1 1.2 9.5 3.4 174 12 177 165 5.4 0.3 6 4.8 04/22/2006 16:30:00 7.3 0.5 8.8 6.1 7.2 0.6 8.8 5.7 7.5 0.6 8.8 5.7 163 17 164 165 5.8 0.2 6.2 5 04/22/2006 16:40:00 6.8 0.6 8.4 5.3 6.6 0.6 8.8 4.9 7 0.6 9.1 5.3 164 13 158 165 5.4 0.3 6.2 5 04/22/2006 16:50:00 7.6 0.5 8.8 6.1 7.4 0.5 8.8 5.7 7.8 0.6 8.8 6.1 169 12 177 165 5.2 0.4 6 4.5 04/22/2006 17:00:00 8 0.5 9.1 6.5 7.7 0.5 8.8 6.1 8.2 0.6 9.5 6.5 169 4 166 165 4.4 0.1 4.8 4 04/22/2006 17:10:00 7.4 0.5 8.8 5.7 7.2 0.4 8.4 6.1 7.6 0.5 8.8 6.5 169 4 164 165 4.1 0.1 4.5 3.5 04/22/2006 17:20:00 6.8 0.6 8 5.3 6.6 0.5 8 4.9 7 0.6 8.4 4.6 167 6 171 165 4 0.1 4.3 3.5 04/22/2006 17:30:00 5.7 0.7 7.2 4.2 5.5 0.7 7.2 3.8 5.9 0.6 8 4.6 169 9 165 165 4.3 0.2 5 3.8 04/22/2006 17:40:00 6.8 0.6 8 5.3 6.6 0.5 7.6 4.9 7 0.6 8.4 5.3 168 7 170 165 4.8 0.2 5.2 4.3 04/22/2006 17:50:00 7 0.5 8.4 4.9 6.7 0.5 8 4.6 7.3 0.5 8.8 5.7 173 9 169 165 4.6 0.1 4.8 4.3 04/22/2006 18:00:00 6.5 0.6 8 4.6 6.3 0.6 7.6 4.9 6.6 0.7 8.4 4.6 178 7 181 165 4.7 0.1 5 4.3 04/22/2006 18:10:00 6.5 0.6 8.4 4.9 6.2 0.6 8 4.6 6.5 0.7 8.8 4.9 177 8 175 165 4.2 0.3 4.8 3.5 04/22/2006 18:20:00 5 0.8 6.8 3 4.9 0.8 6.5 3 5.1 0.9 7.2 3 176 12 173 165 3.6 0 3.8 3.3 04/22/2006 18:30:00 4.2 0.5 6.1 2.6 4.2 0.5 6.1 3 4.4 0.4 5.7 3.4 176 8 179 165 4.1 0.1 4.3 3.5 04/22/2006 18:40:00 4.9 0.5 6.1 3.8 4.8 0.5 6.1 3.4 5.1 0.5 6.5 3.8 171 5 166 165 3.8 0.2 4.3 3.3 04/22/2006 18:50:00 4 0.4 5.3 3 3.9 0.4 4.9 3 3.9 0.4 4.9 3 174 7 164 165 3.3 0 3.5 3 04/22/2006 19:00:00 4.3 0.5 5.7 2.6 4.2 0.5 5.3 3 4.4 0.6 6.1 3 174 9 168 165 3.3 0 3.5 3 04/22/2006 19:10:00 4.1 0.4 5.3 3 4 0.4 4.9 3 4.2 0.5 5.3 3 173 9 187 165 3.5 0 3.5 3.3 04/22/2006 19:20:00 5.2 0.5 6.1 3.8 5 0.5 6.1 3.8 5.3 0.6 6.8 3.8 169 10 164 165 3.2 0 3.5 3 04/22/2006 19:30:00 5.5 0.3 6.1 4.6 5.3 0.3 5.7 4.2 5.6 0.3 6.1 4.6 167 12 164 165 3.2 0 3.5 3 04/22/2006 19:40:00 5.2 0.5 6.1 3.4 5 0.5 6.1 3.4 5.3 0.5 6.5 3.8 172 9 177 165 3.1 0 3.3 3 04/22/2006 19:50:00 4.9 0.7 6.1 3.4 4.7 0.6 6.1 3 4.9 0.6 6.1 3.4 171 6 169 165 2.9 0 3.3 2.6 04/22/2006 20:00:00 5 0.5 6.1 3.8 4.8 0.5 5.7 3.4 5.1 0.5 6.1 3.8 172 10 172 165 2.7 0 2.8 2.6 04/22/2006 20:10:00 5.3 0.4 6.1 3.8 5.1 0.4 6.1 3.8 5.3 0.5 6.5 4.2 169 8 165 165 2.5 0 2.8 2.6 04/22/2006 20:20:00 4.6 0.4 5.3 3.4 4.4 0.4 5.3 3.4 4.6 0.4 5.3 3.4 170 11 172 165 2.4 0 2.6 2.3 04/22/2006 20:30:00 3.8 0.4 4.9 3 3.8 0.4 4.9 3 4 0.4 4.9 3 175 7 168 165 2.3 0 2.6 2.3 04/22/2006 20:40:00 4.3 0.3 4.9 3.4 4.2 0.3 4.9 3.4 4.5 0.3 5.3 3.8 171 5 173 165 2.2 0 2.3 2.1 04/22/2006 20:50:00 4.4 0.4 5.3 3.4 4.3 0.4 4.9 3 4.5 0.4 5.3 3.4 174 5 170 165 2.1 0 2.3 1.8 04/22/2006 21:00:00 4.3 0.4 4.9 3.4 4.2 0.4 4.9 3.4 4.4 0.3 5.3 3.4 173 5 175 165 2.1 0 2.3 1.8 04/22/2006 21:10:00 4.1 0.4 5.3 3 4 0.4 4.9 3 4.3 0.4 4.9 3.4 170 9 170 165 2 0 2.1 1.8 04/22/2006 21:20:00 4.2 0.5 5.3 3 4.1 0.4 4.9 3 4.3 0.5 5.7 3.4 172 6 169 165 1.9 0 2.1 1.8 04/22/2006 21:30:00 4.1 0.5 4.9 2.6 4.1 0.4 4.9 3 4.3 0.4 5.3 3 169 5 165 165 1.9 0 2.3 1.8 04/22/2006 21:40:00 4.3 0.4 5.3 3 4.2 0.4 4.9 3 4.5 0.5 5.3 3.4 174 6 176 165 1.8 0 2.1 1.6 04/22/2006 21:50:00 4.5 0.2 4.9 3.8 4.4 0.2 4.9 3.8 4.7 0.2 5.3 4.2 176 4 177 165 1.7 0 1.8 1.6 04/22/2006 22:00:00 4.3 0.3 4.9 3.8 4.2 0.2 4.9 3.8 4.6 0.3 5.7 3.8 172 4 177 165 1.7 0 1.8 1.6 04/22/2006 22:10:00 3.9 0.2 4.6 3.4 3.8 0.2 4.6 3.4 4.2 0.2 4.9 3.8 171 3 174 165 1.7 0 1.8 1.6 04/22/2006 22:20:00 4.2 0.3 4.9 3.4 4.1 0.3 4.6 3.4 4.6 0.3 5.3 3.8 171 4 169 165 1.6 0 1.8 1.4 04/22/2006 22:30:00 3.8 0.4 4.6 3 3.7 0.3 4.2 3 4.1 0.3 4.6 3 173 4 173 165 1.6 0 1.8 1.4 04/22/2006 22:40:00 3.4 0.2 3.8 3 3.3 0.2 3.8 3 3.7 0.2 4.2 3 167 4 167 165 1.5 0 1.6 1.4 04/22/2006 22:50:00 3.3 0.3 3.8 2.6 3.2 0.3 3.8 2.6 3.6 0.3 4.2 3 167 3 165 165 1.4 0 1.6 1.4 04/22/2006 23:00:00 3.5 0.2 3.8 2.6 3.5 0.2 3.8 2.6 3.7 0.2 4.2 3.4 167 5 165 165 1.4 0 1.6 1.4 04/22/2006 23:10:00 3.7 0.2 4.2 3.4 3.7 0.2 4.2 3.4 4 0.2 4.2 3.4 174 2 167 165 1.4 0 1.6 1.4 04/22/2006 23:20:00 3.3 0.4 4.2 2.3 3.3 0.4 4.2 2.3 3.5 0.4 4.6 2.6 175 3 171 165 1.5 0 1.8 1.4 04/22/2006 23:30:00 2.3 0.2 2.6 1.9 2.4 0.2 3 1.9 2.9 0.2 3.4 2.3 175 6 171 165 1.5 0 1.6 1.4 04/22/2006 23:40:00 2.7 0.3 3.4 1.9 2.7 0.2 3.4 1.9 3 0.2 3.4 2.6 176 7 171 165 1.6 0 1.8 1.4 04/22/2006 23:50:00 2.1 0.3 3 1.5 2.1 0.3 3 1.5 2.3 0.3 3 1.5 167 4 166 165 1.4 0.1 1.6 1.4 04/23/2006 00:00:00 2.7 0.3 3.4 1.5 2.7 0.3 3 1.5 2.8 0.3 3.4 1.9 171 4 178 165 1.4 0 1.6 1.1 04/23/2006 00:10:00 2.5 0.3 3 1.9 2.5 0.2 3 1.9 2.8 0.3 3.4 2.3 170 3 172 165 1.5 0 1.6 1.4 04/23/2006 00:20:00 2 0.2 2.3 1.5 2 0.2 2.3 1.5 2.3 0.2 2.6 1.5 169 4 171 165 1.5 0 1.6 1.4 04/23/2006 00:30:00 2.4 0.3 3 1.9 2.5 0.3 3 1.9 2.8 0.2 3.4 2.3 170 6 165 165 1.6 0 1.8 1.4 04/23/2006 00:40:00 2.4 0.2 3 1.9 2.4 0.2 3 1.9 2.7 0.2 3 2.3 154 4 162 165 1.2 0 1.6 1.1 04/23/2006 00:50:00 2.1 0.3 2.6 1.5 2.1 0.3 2.6 1.5 2.4 0.2 3 1.5 158 5 150 165 1.1 0 1.4 0.9 04/23/2006 01:00:00 2.4 0.2 3.4 1.9 2.4 0.2 3 1.9 2.4 0.2 3 1.9 161 5 160 165 1.1 0 1.4 0.9 04/23/2006 01:10:00 2.1 0.4 3 1.5 2.1 0.4 3 1.5 2.4 0.3 3 1.9 159 5 165 165 1.2 0 1.4 1.1 04/23/2006 01:20:00 1.7 0.2 2.3 1.5 1.5 0.2 1.9 1.1 1.9 0.2 2.3 1.5 163 4 160 165 1.1 0 1.4 0.9 04/23/2006 01:30:00 1.6 0.3 2.3 0.7 1.4 0.3 2.3 0.7 1.9 0.3 2.6 1.5 169 4 171 165 1.2 0 1.4 0.9 04/23/2006 01:40:00 1.9 0.3 2.6 1.5 1.9 0.2 2.3 1.1 2.2 0.2 2.6 1.5 190 6 183 165 1.4 0 1.6 1.1 04/23/2006 01:50:00 1.5 0.3 2.3 0.7 1.5 0.3 2.6 0.7 2 0.2 2.3 1.5 197 1 200 165 1.4 0.1 1.6 1.1 04/23/2006 02:00:00 1.3 0.4 2.3 0.4 1.4 0.4 2.3 0.4 1.8 0.3 2.6 1.1 200 1 204 165 1.4 0 1.6 1.1 04/23/2006 02:10:00 1.4 0.4 2.3 0.7 1.5 0.4 2.3 0.4 2.1 0.3 2.6 1.5 182 9 186 165 1.5 0 1.6 1.4 04/23/2006 02:20:00 1 0.3 1.9 0.7 1.1 0.3 1.9 0.7 1.7 0.2 1.9 1.1 171 1 166 165 1.4 0 1.6 1.1 04/23/2006 02:30:00 0.8 0.4 1.5 0.4 0.8 0.4 1.5 0.4 1.5 0.3 2.3 0.7 167 1 170 165 1.3 0 1.4 1.1 04/23/2006 02:40:00 0.6 0.3 1.5 0.4 0.4 0.2 1.5 0.4 1.1 0.3 1.5 0.7 166 1 165 165 1.1 0 1.4 0.9 04/23/2006 02:50:00 0.6 0.3 1.1 0.4 0.4 0 0.4 0.4 1 0.3 1.5 0.4 165 0 165 165 1.2 0.1 1.4 0.9 04/23/2006 03:00:00 0.6 0.3 1.5 0.4 0.4 0 0.4 0.4 1 0.3 1.9 0.4 175 4 176 165 1.3 0 1.6 1.1 04/23/2006 03:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.5 0.2 1.1 0.4 175 0 165 165 1.1 0 1.4 0.9 04/23/2006 03:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.7 0.4 151 49 165 165 0.6 0.1 0.9 0.2 04/23/2006 03:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0.1 0.7 0.4 41 17 165 165 0.2 0 0.4 0.2 04/23/2006 03:40:00 0.7 0.4 1.5 0.4 0.6 0.4 1.9 0.4 1 0.5 1.9 0.4 128 29 146 165 0.7 0.2 1.1 0.2 04/23/2006 03:50:00 0.8 0.5 1.5 0.4 0.8 0.5 1.9 0.4 1.4 0.3 1.9 0.7 146 0 146 165 1 0 1.4 0.9 04/23/2006 04:00:00 0.7 0.3 1.5 0.4 0.8 0.3 1.5 0.4 1.4 0.3 1.9 0.4 142 6 134 165 1.3 0.1 1.6 0.9 04/23/2006 04:10:00 0.7 0.5 1.9 0.4 0.7 0.6 1.9 0.4 1.4 0.5 2.3 0.4 125 9 138 165 1.2 0 1.4 1.1 04/23/2006 04:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.5 0.2 1.1 0.4 112 0 165 165 1.1 0 1.4 0.9 04/23/2006 04:30:00 0.4 0 0.4 0.4 0.4 0.2 1.1 0.4 0.7 0.4 1.5 0.4 112 0 165 165 1.4 0 1.6 1.4 04/23/2006 04:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0.1 1.1 0.4 112 1 165 165 1.5 0 1.6 1.4 04/23/2006 04:50:00 0.4 0.1 1.1 0.4 0.4 0.1 1.1 0.4 0.8 0.3 1.5 0.4 57 20 44 165 1.4 0 1.6 1.1 04/23/2006 05:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.6 0.2 1.5 0.4 43 1 165 165 1.2 0 1.4 1.1 04/23/2006 05:10:00 0.6 0.4 1.9 0.4 0.6 0.5 1.9 0.4 0.6 0.4 1.5 0.4 92 8 83 165 1.4 0 1.6 1.4 04/23/2006 05:20:00 1.5 0.2 1.9 0.7 1.5 0.2 1.9 1.1 1.7 0.3 2.3 0.7 92 5 87 165 1.4 0 1.6 1.4 04/23/2006 05:30:00 0.9 0.5 1.9 0.4 1 0.5 1.9 0.4 1.5 0.3 2.3 0.7 104 5 100 165 1.4 0 1.6 1.4 04/23/2006 05:40:00 0.5 0.3 1.5 0.4 0.5 0.2 1.5 0.4 0.9 0.4 1.9 0.4 100 10 91 165 1.5 0 1.8 1.4 04/23/2006 05:50:00 1.2 0.3 1.9 0.4 1.2 0.3 1.9 0.4 1.6 0.3 2.3 0.4 113 1 112 165 1.6 0 1.8 1.4 04/23/2006 06:00:00 0.4 0.2 1.5 0.4 0.5 0.3 1.5 0.4 1.1 0.3 1.9 0.4 118 3 119 165 1.7 0 1.8 1.6 04/23/2006 06:10:00 1.2 0.7 2.3 0.4 1.2 0.7 2.6 0.4 1.7 0.5 2.6 0.7 89 0 90 165 1.7 0 1.8 1.6 04/23/2006 06:20:00 2 0.4 2.6 1.1 2 0.5 3 1.1 2.2 0.3 3 1.5 71 11 82 165 1.8 0 1.8 1.8 04/23/2006 06:30:00 2 0.3 2.6 1.5 2.1 0.3 2.6 1.5 2.3 0.3 3 1.5 58 8 57 165 1.8 0 1.8 1.6 04/23/2006 06:40:00 2 0.3 2.6 1.5 2.1 0.3 2.6 1.5 2.2 0.3 3 1.5 82 6 75 165 1.8 0 1.8 1.6 04/23/2006 06:50:00 1.8 0.4 2.6 0.7 1.8 0.5 2.6 0.7 2.1 0.4 3 1.1 79 13 91 165 2.2 0 2.3 1.8 04/23/2006 07:00:00 1.8 0.5 3 0.4 1.7 0.6 3 0.4 2.2 0.5 3.4 1.1 28 9 29 165 2 0.1 2.3 1.8 04/23/2006 07:10:00 2.9 0.3 3.4 2.3 2.9 0.3 3.4 2.3 3.4 0.2 3.8 2.6 29 3 33 165 1.7 0 1.8 1.4 04/23/2006 07:20:00 2.3 0.3 3 1.9 2.3 0.3 3 1.5 2.9 0.2 3.4 2.3 33 6 42 165 1.5 0 1.6 1.4 04/23/2006 07:30:00 2.5 0.2 3 2.3 2.5 0.2 3 2.3 2.8 0.2 3 2.3 40 3 42 165 1.7 0 1.8 1.4 04/23/2006 07:40:00 2.8 0.2 3.4 2.3 2.8 0.2 3.4 2.3 3.1 0.2 3.4 2.3 35 2 37 165 1.8 0 1.8 1.6 04/23/2006 07:50:00 2.8 0.6 4.2 0.4 2.9 0.6 3.8 0.7 2.9 0.6 4.2 1.5 35 9 37 165 2 0 2.3 1.8 04/23/2006 08:00:00 2.4 0.4 3 1.1 2.4 0.4 3.4 1.1 2.6 0.4 3.4 1.5 37 7 34 165 2.1 0 2.3 1.8 04/23/2006 08:10:00 2.5 0.5 3.4 1.1 2.4 0.6 3.4 0.4 2.8 0.4 3.4 1.5 24 8 29 165 2.4 0 2.6 2.3 04/23/2006 08:20:00 2.2 0.6 3.4 0.4 2.3 0.6 3.4 0.7 2.5 0.5 3.4 1.5 27 9 31 165 2.9 0.1 3.3 2.3 04/23/2006 08:30:00 2.6 0.5 3.4 1.5 2.6 0.5 3.4 1.1 2.8 0.5 3.8 1.9 36 10 31 165 3.1 0 3.5 2.8 04/23/2006 08:40:00 2.7 0.5 4.6 1.5 2.7 0.5 4.6 1.5 3 0.4 4.2 1.9 44 9 43 165 2.6 0 2.8 2.6 04/23/2006 08:50:00 2.9 0.4 3.8 1.9 2.9 0.4 3.8 1.9 3.2 0.4 4.2 1.9 42 8 39 165 2.6 0 2.8 2.6 04/23/2006 09:00:00 3 0.5 3.8 1.9 3 0.5 3.8 1.5 3.1 0.4 4.2 1.9 47 6 43 165 2.8 0 3 2.6 04/23/2006 09:10:00 2.7 0.5 3.8 1.5 2.7 0.5 3.8 1.5 2.9 0.5 4.2 1.5 51 11 48 165 2.7 0 2.8 2.6 04/23/2006 09:20:00 3.2 0.6 5.3 1.9 3.1 0.6 5.3 1.9 3.2 0.6 4.6 1.9 49 13 50 165 2.8 0 3 2.6 04/23/2006 09:30:00 3.8 0.5 5.3 2.3 3.7 0.6 5.3 2.3 3.9 0.5 5.3 2.3 39 7 32 165 2.7 0 2.8 2.6 04/23/2006 09:40:00 3.5 0.4 4.6 2.3 3.4 0.4 4.2 2.3 3.7 0.4 4.6 2.6 35 7 31 165 2.7 0 2.8 2.6 04/23/2006 09:50:00 3.9 0.4 4.9 2.6 3.7 0.4 4.6 2.3 3.9 0.4 4.9 3 33 7 32 165 2.8 0 3 2.6 04/23/2006 10:00:00 3 0.5 3.8 1.5 2.9 0.5 3.8 1.1 3.1 0.5 4.2 2.3 34 10 36 165 2.8 0 2.8 2.6 04/23/2006 10:10:00 3.4 0.6 4.6 1.9 3.3 0.6 4.6 1.1 3.6 0.6 4.9 1.9 29 8 21 165 2.9 0 3 2.8 04/23/2006 10:20:00 3.1 0.6 4.2 1.5 2.9 0.6 4.2 1.1 3.1 0.5 4.6 1.9 28 7 18 165 3.3 0.2 3.8 2.8 04/23/2006 10:30:00 2.8 0.7 4.9 1.5 2.6 0.7 4.9 0.7 2.9 0.6 4.9 1.1 28 13 20 165 4 0 4.3 3.5 04/23/2006 10:40:00 1.9 0.4 3 1.1 1.6 0.5 2.6 0.7 2 0.4 3 1.1 35 10 20 165 3.8 0.2 4.3 3.5 04/23/2006 10:50:00 2.4 0.4 3.4 1.5 2 0.5 3 0.7 2.4 0.5 3.8 1.1 38 11 31 165 3.5 0 3.8 3.3 04/23/2006 11:00:00 3 0.5 3.8 1.5 2.7 0.6 3.8 0.7 3 0.6 3.8 1.5 32 6 39 165 3.1 0.1 3.5 2.8 04/23/2006 11:10:00 2.4 0.4 3.4 1.5 2 0.5 3 0.7 2.4 0.4 3.8 1.1 29 10 39 165 3.3 0.2 3.5 2.8 04/23/2006 11:20:00 2.6 0.6 4.6 1.5 2.2 0.6 4.6 0.7 2.5 0.6 4.9 1.5 36 10 31 165 4.1 0.3 4.5 3.5 04/23/2006 11:30:00 4.4 0.5 5.7 2.6 4.1 0.5 5.7 2.3 4.3 0.6 5.7 2.6 30 8 31 165 3.6 0.3 4.5 3.3 04/23/2006 11:40:00 5.2 0.4 6.1 3.4 5.1 0.5 6.1 3.4 5.4 0.5 6.1 3.4 30 5 24 165 3 0.1 3.5 2.8 04/23/2006 11:50:00 5.5 0.4 6.8 4.6 5.5 0.5 6.5 4.2 5.8 0.5 6.8 4.6 36 4 41 165 2.7 0 3 2.6 04/23/2006 12:00:00 5.2 0.5 6.5 3.8 5 0.6 6.1 3.4 5.2 0.7 6.8 3.4 31 7 26 165 3.5 0.4 4.5 2.8 04/23/2006 12:10:00 5.2 0.4 6.1 3.8 5 0.5 6.1 3 5.2 0.6 6.5 3.4 30 7 28 165 4.4 0.1 4.8 4.3 04/23/2006 12:20:00 5.4 0.5 6.5 3.8 5.2 0.5 6.5 3.8 5.4 0.5 6.5 3.8 30 8 27 165 4.7 0.2 5 4.3 04/23/2006 12:30:00 4.6 0.5 6.5 3.4 4.4 0.5 6.1 3 4.7 0.5 6.1 3 33 5 32 165 4.6 0.2 5 4.3 04/23/2006 12:40:00 4.7 0.8 6.8 2.6 4.3 0.8 6.1 2.3 4.6 0.9 6.5 2.6 25 12 23 165 4.9 0.3 5.5 4.3 04/23/2006 12:50:00 4.9 0.4 6.1 3.4 4.7 0.5 6.1 3.4 4.7 0.5 6.1 3 31 6 26 165 4.8 0.1 5 4.3 04/23/2006 13:00:00 4.4 0.7 5.7 2.6 4.2 0.7 5.7 2.3 4.4 0.8 6.1 2.6 38 9 52 165 4.8 0.2 5.5 4.5 04/23/2006 13:10:00 4.6 0.8 6.5 2.6 4.4 0.9 6.5 2.6 4.6 0.9 6.8 2.6 32 11 30 165 5.4 0.1 5.7 4.8 04/23/2006 13:20:00 4.5 0.5 6.5 3.4 4.3 0.6 6.1 2.3 4.5 0.6 6.5 3 27 7 22 165 5.5 0.2 6 5 04/23/2006 13:30:00 4.3 0.9 7.2 2.6 4.1 1 6.8 2.3 4.1 1 6.8 1.9 24 11 27 165 6.1 0.4 6.7 5 04/23/2006 13:40:00 4.9 0.6 6.5 3 4.3 0.9 6.5 1.9 4.8 0.6 6.5 3.4 15 10 19 165 5.5 0.1 6.2 5 04/23/2006 13:50:00 5.1 0.5 6.5 3.8 4.9 0.6 6.5 3.4 5.1 0.6 6.1 3.4 22 7 19 165 5.7 0 5.7 5.2 04/23/2006 14:00:00 4.6 0.6 6.1 3 4.5 0.7 6.1 3 4.5 0.7 6.1 3 27 8 25 165 5.7 0.1 6 5 04/23/2006 14:10:00 4.6 0.6 6.1 3 4.5 0.6 5.7 2.6 4.5 0.6 6.1 3 30 7 33 165 5.7 0.3 6.2 5 04/23/2006 14:20:00 4.3 0.5 5.3 2.6 4 0.7 5.3 1.9 4.2 0.6 5.7 2.6 20 8 26 165 5.5 0.2 6 4.8 04/23/2006 14:30:00 4.8 0.8 7.2 2.6 4.3 1.1 6.8 1.9 4.8 0.8 6.8 3.4 17 8 14 165 4.9 0.3 5.7 4.3 04/23/2006 14:40:00 4.9 0.9 7.2 2.3 4.4 1 6.5 1.9 4.8 0.9 6.8 2.3 16 9 14 165 4.8 0.4 5.5 4.3 04/23/2006 14:50:00 5 0.7 7.2 3 4.7 0.7 6.8 3 5 0.7 6.8 2.6 21 8 29 165 5.8 0.3 6.5 5.2 04/23/2006 15:00:00 5.1 0.6 6.5 3.4 4.9 0.7 6.8 3 4.9 0.7 6.8 3.4 25 9 23 165 5 0.3 5.5 4 04/23/2006 15:10:00 6.1 0.8 8 4.2 5.9 0.8 7.6 3.8 5.9 0.8 8 4.2 27 7 15 165 4 0.2 4.5 3.3 04/23/2006 15:20:00 6.7 0.6 8 4.6 6.7 0.7 8 4.9 6.5 0.8 8.4 4.2 32 6 40 165 3.6 0.1 3.8 3.3 04/23/2006 15:30:00 6.8 0.9 9.1 4.2 6.7 1 8.8 4.2 6.6 1 8.8 4.2 26 8 25 165 3.5 0.3 3.8 2.6 04/23/2006 15:40:00 7.5 1.2 10.7 5.3 6.5 1 10.3 3.8 7.1 1.2 11.1 4.6 19 14 7 165 2.2 0.3 2.8 1.8 04/23/2006 15:50:00 7.9 1 11.1 5.3 7.6 1.2 11.1 4.2 7.8 1 10.3 5.7 348 8 349 165 2.3 0 2.6 1.8 04/23/2006 16:00:00 6 0.5 7.6 4.9 5.9 0.6 7.6 3.8 5.8 0.5 7.2 4.2 343 8 345 165 2.6 0 2.8 2.3 04/23/2006 16:10:00 6.5 0.7 8.4 4.9 6.1 1 8.4 2.6 6.4 0.7 8.4 4.6 349 5 345 165 3 0.1 3.5 2.8 04/23/2006 16:20:00 6.9 0.7 9.1 5.3 6.8 0.8 9.1 4.9 6.6 0.8 8.4 4.9 340 8 332 165 3.4 0 3.5 3 04/23/2006 16:30:00 7.2 0.8 10.7 5.3 7 1.1 11.1 3.8 6.9 0.9 10.3 4.9 343 9 347 165 3.3 0 3.5 3 04/23/2006 16:40:00 7.5 1 11.1 5.3 6.5 1.6 11.1 3.4 7.3 1.1 11.1 5.3 351 9 351 165 4 0.1 4.3 3.5 04/23/2006 16:50:00 7.9 0.9 11.1 4.9 6.5 1.4 9.5 3.4 7.8 1 11.1 5.3 356 9 9 165 4.1 0.3 4.5 3.5 04/23/2006 17:00:00 8.7 1.3 12.2 6.5 7.9 2 12.2 4.2 8.4 1.3 12.6 6.1 349 8 343 165 3.5 0.1 3.8 3.3 04/23/2006 17:10:00 9 1.3 14.1 6.5 7.3 1.7 12.2 3.4 9 1.3 12.2 6.1 354 9 7 165 3.9 0.2 4.3 3.3 04/23/2006 17:20:00 7.1 1.2 9.9 4.2 7 1.4 10.3 2.6 6.8 1.2 10.3 4.2 341 9 336 165 4.1 0.3 4.8 3.5 04/23/2006 17:30:00 6.9 0.9 9.1 3.8 5.9 1.1 8.4 3.4 7 1 9.9 4.6 356 12 4 165 4.1 0.4 4.8 3.5 04/23/2006 17:40:00 8 1.3 12.6 5.3 7.4 1.7 13 3.4 7.8 1.3 11.8 5.3 348 15 332 165 3.8 0.2 4.3 3.5 04/23/2006 17:50:00 8.4 1.3 11.8 5.7 8.3 1.3 11.5 5.3 7.9 1.5 12.2 3.8 328 14 298 165 4.1 0.1 4.5 3.8 04/23/2006 18:00:00 7.5 1.2 10.7 4.6 7.3 1.3 11.1 4.2 7.3 1.1 10.3 4.2 333 11 329 165 3.7 0.3 4.5 3 04/23/2006 18:10:00 7.7 1.6 12.6 3.4 7.6 1.6 12.6 2.6 7.5 1.5 11.8 3.4 330 12 322 165 3 0 3.3 2.8 04/23/2006 18:20:00 10.6 1.9 15.3 6.5 10.2 2.2 15.6 5.3 10.4 2 16.1 6.5 336 12 318 165 3.4 0.2 3.8 3 04/23/2006 18:30:00 10.3 1 13 8.4 10.1 1.2 13 6.1 10.2 1.3 14.1 7.2 341 9 360 165 3.6 0.1 3.8 3.3 04/23/2006 18:40:00 11.7 1.6 15.6 6.8 11.6 1.8 15.3 6.5 11.4 1.5 15.3 7.2 337 8 339 165 3.1 0.1 3.5 3 04/23/2006 18:50:00 11.8 1.5 15.3 8 11.3 1.6 16.1 6.8 11.6 1.5 15.3 8 344 10 354 165 3.4 0 3.5 3 04/23/2006 19:00:00 10.4 1.5 14.1 7.2 10.2 1.6 14.1 6.8 10 1.5 14.1 7.2 332 13 334 165 3.6 0 3.8 3.3 04/23/2006 19:10:00 12.2 1.7 17.9 8.4 11.9 1.7 16.1 5.7 11.8 1.7 16.4 8 340 10 5 165 3.4 0 3.5 3 04/23/2006 19:20:00 13.7 1.9 17.9 8.4 13.4 2.2 17.9 7.2 13 2.3 17.6 6.5 330 16 339 165 2.9 0 3.3 2.6 04/23/2006 19:30:00 13.6 1.7 17.9 9.1 13.6 1.8 17.6 8 13.5 1.7 17.6 9.1 334 11 343 165 2.6 0 2.8 2.6 04/23/2006 19:40:00 14.2 1.8 19.9 7.2 13.9 2 19.5 7.6 13.7 2.2 19.9 7.2 325 15 321 165 2.6 0 2.8 2.6 04/23/2006 19:50:00 15 1.9 19.9 10.7 14.8 2 19.5 10.7 14.3 2.3 19.5 8 324 14 313 165 2.5 0 2.6 2.6 04/23/2006 20:00:00 14.5 1.7 18.7 10.3 14.3 1.7 19.9 10.3 13.8 1.8 18.7 9.1 329 15 346 165 2.5 0 2.8 2.6 04/23/2006 20:10:00 14.5 2.1 19.1 9.9 14.2 2.2 19.1 8.8 13.9 2.2 19.9 8.8 329 16 327 165 2.6 0 2.8 2.6 04/23/2006 20:20:00 14.5 1.7 19.9 9.1 14.4 1.7 20.2 9.1 13.7 2.1 21.4 8 323 13 325 165 2.5 0 2.8 2.3 04/23/2006 20:30:00 15.5 2.1 21 9.5 15.2 2.1 21 9.5 14.8 1.9 19.9 10.3 328 15 319 165 2.5 0 2.8 2.3 04/23/2006 20:40:00 15.9 2.1 21.8 10.7 15.7 2.2 21.4 9.5 15.4 2.3 22.9 9.9 330 15 325 165 2.4 0 2.6 2.3 04/23/2006 20:50:00 17.3 2.3 23.3 9.9 17.1 2.4 23.3 8.8 16.7 2.4 22.9 10.7 323 13 310 165 2.6 0 2.8 2.3 04/23/2006 21:00:00 16.9 2.3 23.7 9.5 16.7 2.3 23.3 8.8 16 2.2 21.8 8.4 321 12 315 165 2.5 0 2.8 2.3 04/23/2006 21:10:00 17.3 2.2 22.9 11.1 17.2 2.2 22.9 11.5 16.7 2.3 22.6 11.5 318 8 306 165 2.5 0 2.8 2.3 04/23/2006 21:20:00 17.4 1.8 23.3 13.7 17.2 1.8 22.9 13 16.7 1.8 22.1 12.2 320 8 316 165 2.3 0 2.6 2.3 04/23/2006 21:30:00 17.9 1.4 23.7 13.7 17.7 1.4 23.3 13.7 17.3 1.7 23.3 12.2 318 7 318 165 2.3 0 2.6 2.1 04/23/2006 21:40:00 18.2 1.9 23.7 14.1 17.9 1.9 23.7 13.3 17.3 1.8 22.6 13.3 318 8 319 165 2.3 0 2.6 2.3 04/23/2006 21:50:00 18.5 1.5 22.9 13.7 18.2 1.5 22.6 13 17.8 1.5 21.8 13 318 6 304 165 2.3 0 2.6 2.3 04/23/2006 22:00:00 18 1.6 22.1 13.7 17.8 1.6 22.1 13.7 16.6 1.5 21.8 12.2 315 7 310 165 2.3 0 2.6 2.1 04/23/2006 22:10:00 18.4 1.6 22.6 14.5 18.2 1.6 22.1 14.1 17.6 1.7 22.9 13.7 318 8 323 165 2.4 0 2.6 2.3 04/23/2006 22:20:00 18.6 1.8 25.6 14.5 18.5 1.9 25.6 14.5 17.4 2.3 25.2 11.1 314 7 315 165 2.4 0.1 2.8 2.3 04/23/2006 22:30:00 18.6 1.5 23.7 15.3 18.5 1.5 24 14.9 16.9 2 24 11.1 313 6 326 165 2.4 0 2.6 2.3 04/23/2006 22:40:00 18 1.7 21.8 13 17.8 1.7 21.4 13 16.6 2 22.1 11.5 314 8 309 165 2.3 0 2.6 2.1 04/23/2006 22:50:00 18.9 1.6 22.6 14.5 18.8 1.7 22.6 14.1 17.5 1.7 22.6 13 314 6 309 165 2.3 0 2.6 2.3 04/23/2006 23:00:00 18.6 1.9 25.2 14.5 18.5 1.8 24.8 14.5 17.4 1.7 22.1 12.6 314 6 317 165 2.3 0 2.6 2.1 04/23/2006 23:10:00 18.7 1.5 24.4 15.6 18.5 1.5 24.4 15.6 17.6 1.5 21.8 13.7 314 5 312 165 2.3 0 2.6 2.1 04/23/2006 23:20:00 20.7 1.8 26.8 16.4 20.5 1.9 26.8 16.4 19.2 2 26.3 13.3 313 5 312 165 2.4 0 2.6 2.3 04/23/2006 23:30:00 19.8 1.5 24 14.9 19.7 1.5 24.4 15.3 18.3 1.6 23.7 14.5 312 5 307 165 2.4 0 2.6 2.3 04/23/2006 23:40:00 20.2 2.2 28.7 16.1 20.1 2.2 28.3 16.1 19.2 2.2 26.3 14.1 315 6 303 165 2.5 0 2.8 2.3 04/23/2006 23:50:00 20 1.5 26.8 17.2 19.8 1.5 26 16.8 18.7 1.8 26.3 14.1 313 5 323 165 2.5 0 2.8 2.3 04/24/2006 00:00:00 20.6 1.7 25.6 14.9 20.5 1.7 25.6 15.3 18.8 1.7 25.2 13.7 311 6 297 165 2.6 0 2.8 2.3 04/24/2006 00:10:00 20.1 1.6 23.7 15.6 20 1.7 24 14.9 18.4 1.9 22.9 12.6 311 6 308 165 2.7 0 2.8 2.6 04/24/2006 00:20:00 19.8 1.6 24.4 15.3 19.7 1.6 24 14.9 18.5 1.9 23.7 13.3 314 6 312 165 2.6 0.1 2.8 2.6 04/24/2006 00:30:00 21.2 1.8 25.2 17.2 21.1 1.9 25.6 16.8 19.5 2 24.8 14.1 311 6 302 165 2.5 0 2.8 2.3 04/24/2006 00:40:00 21.3 1.7 26.3 17.2 21.2 1.7 26.3 16.8 20.3 1.7 24.8 15.3 313 5 304 165 2.3 0 2.6 2.3 04/24/2006 00:50:00 21.7 1.9 25.6 16.8 21.5 1.9 26 16.1 20.6 2.1 25.2 15.6 313 5 307 165 2.3 0 2.3 2.1 04/24/2006 01:00:00 21.9 1.8 26.3 16.4 21.8 1.9 26.3 16.4 21.3 2.1 26.8 15.6 316 6 310 165 2.3 0 2.6 2.1 04/24/2006 01:10:00 21.5 1.9 27.5 14.9 21.4 2 27.5 15.6 20.8 2 28.3 15.6 317 7 325 165 2.3 0 2.6 2.1 04/24/2006 01:20:00 20.4 1.4 24.8 16.8 20.3 1.5 24.8 16.4 19.3 1.5 23.7 15.6 314 6 302 165 2.1 0 2.3 1.8 04/24/2006 01:30:00 21 1.5 25.6 17.6 20.9 1.5 25.2 17.6 20.2 1.9 26 14.9 315 6 310 165 2.1 0 2.3 2.1 04/24/2006 01:40:00 19.5 1.7 25.2 14.9 19.3 1.7 24.4 14.5 18.7 2 26.3 14.9 317 8 309 165 2.2 0 2.3 1.8 04/24/2006 01:50:00 18.9 2.1 24 14.9 18.7 2.1 24 14.5 18.4 2.2 24.4 13.3 318 9 296 165 2.3 0 2.3 2.1 04/24/2006 02:00:00 17.5 1.7 22.1 13 17.3 1.7 22.6 13 17.2 1.8 24 13 320 9 328 165 2.3 0 2.6 2.1 04/24/2006 02:10:00 18.8 1.7 24.4 15.3 18.6 1.7 23.3 14.9 17.5 1.7 22.9 13 313 8 313 165 2.3 0 2.3 2.3 04/24/2006 02:20:00 18.5 1.7 23.3 13.3 18.3 1.7 23.3 13 17.6 1.9 22.6 11.8 316 8 311 165 2.3 0 2.3 2.1 04/24/2006 02:30:00 18.3 1.7 22.6 14.1 18.2 1.7 22.9 14.1 17.5 2 23.7 11.5 317 9 300 165 2.3 0 2.6 2.1 04/24/2006 02:40:00 17.8 1.9 22.1 11.8 17.7 1.9 22.1 12.2 17.4 1.8 21.4 12.2 322 10 319 165 2.4 0 2.6 2.3 04/24/2006 02:50:00 18.3 1.6 22.1 13 18.1 1.6 21.8 13.3 17.9 1.5 22.6 13.7 317 8 301 165 2.2 0 2.6 1.8 04/24/2006 03:00:00 18.9 1.7 24.4 15.3 18.8 1.7 24.8 14.9 18.2 1.7 24.8 13.7 314 7 321 165 2 0 2.3 1.8 04/24/2006 03:10:00 20.5 2.2 26.3 13.7 20.4 2.2 26 13.3 19.9 2.5 25.6 11.8 317 7 312 165 1.9 0 2.1 1.8 04/24/2006 03:20:00 20.7 2 25.2 15.3 20.5 2.1 25.6 15.3 20.3 2.3 25.6 14.5 318 7 311 165 2.1 0 2.3 1.8 04/24/2006 03:30:00 21.8 1.4 25.2 17.9 21.7 1.4 24.8 17.9 20.8 1.6 24.8 16.4 314 5 314 165 2.2 0 2.3 1.8 04/24/2006 03:40:00 22.6 1.9 26.8 18.3 22.4 2 26.8 17.9 21.7 1.9 27.5 16.4 315 6 307 165 2 0 2.3 1.8 04/24/2006 03:50:00 19 1.5 22.1 13 18.8 1.5 22.6 13.7 18.5 1.7 22.6 12.6 317 6 326 165 1.9 0 2.1 1.8 04/24/2006 04:00:00 20.6 1.7 24.4 15.6 20.4 1.7 24 15.6 19.9 1.9 24.8 14.1 316 5 316 165 1.9 0 2.1 1.6 04/24/2006 04:10:00 20 1.7 24 15.6 19.8 1.6 24 16.1 19.1 2 25.2 13.7 317 7 324 165 1.9 0 2.1 1.8 04/24/2006 04:20:00 19 1.6 23.7 14.1 18.7 1.5 23.7 13.7 18.6 1.7 22.9 13.7 322 8 313 165 1.8 0 1.8 1.6 04/24/2006 04:30:00 18.8 1.9 23.3 13.3 18.6 2 23.3 13 18.1 2 22.9 11.8 320 8 313 165 1.9 0 2.1 1.6 04/24/2006 04:40:00 18.6 1.5 22.9 14.5 18.5 1.5 22.6 14.5 18.2 1.7 22.6 13.3 319 6 316 165 2 0 2.3 1.8 04/24/2006 04:50:00 19.1 1.8 23.7 14.9 18.9 1.9 24 14.9 18.3 1.9 22.9 13.7 319 9 302 165 2.1 0 2.3 1.8 04/24/2006 05:00:00 18.9 1.7 24.8 13.3 18.7 1.7 24.8 13.7 18.6 1.9 25.2 14.5 327 8 314 165 2.3 0 2.6 2.1 04/24/2006 05:10:00 19.1 1.6 22.9 13.3 18.9 1.7 22.6 13 18.5 1.8 22.9 12.2 319 8 323 165 2.3 0 2.6 2.1 04/24/2006 05:20:00 17.8 1.5 22.9 13 17.6 1.5 22.6 12.6 17.3 1.9 23.3 12.2 320 8 314 165 2.4 0 2.6 2.3 04/24/2006 05:30:00 17.5 1.8 21.4 12.2 17.3 1.7 21 12.2 16.9 1.9 22.9 11.1 321 8 319 165 2.4 0 2.6 2.3 04/24/2006 05:40:00 18.5 2 23.7 12.6 18.4 2 24 12.6 17.8 2.2 24.4 12.6 319 8 301 165 2.4 0 2.6 2.3 04/24/2006 05:50:00 17.7 1.6 22.6 12.6 17.4 1.6 22.1 12.2 16.9 1.7 21.4 11.1 319 7 312 165 2.4 0 2.6 2.3 04/24/2006 06:00:00 17.6 1.8 21 11.5 17.3 1.7 21 11.1 17.1 1.8 22.1 11.5 320 8 314 165 2.4 0 2.6 2.3 04/24/2006 06:10:00 17.9 1.4 21.8 14.9 17.6 1.4 21.4 14.5 17.1 1.5 21.8 13 317 6 307 165 2.4 0 2.6 2.3 04/24/2006 06:20:00 17.7 1.7 21.4 11.5 17.4 1.7 21.4 12.2 17.1 1.7 21 10.7 319 8 310 165 2.4 0 2.6 2.3 04/24/2006 06:30:00 18.4 1.6 21.8 13.3 18.2 1.6 22.1 14.1 17.7 1.9 21.8 10.7 317 6 323 165 2.4 0 2.6 2.3 04/24/2006 06:40:00 17.7 1.7 21.8 11.8 17.5 1.7 21.8 11.8 16.7 1.9 20.6 11.5 316 6 305 165 2.4 0 2.6 2.3 04/24/2006 06:50:00 17.9 1.5 21 13.7 17.6 1.5 21 13.7 17.4 1.5 21.8 13.7 319 6 318 165 2.4 0 2.6 2.3 04/24/2006 07:00:00 16.4 1.7 21 12.6 16.2 1.7 20.6 11.8 15.4 1.9 20.2 10.3 315 7 303 165 2.3 0 2.6 2.3 04/24/2006 07:10:00 16.8 1.9 22.6 12.2 16.7 1.9 22.6 12.2 15.4 1.4 19.9 11.1 312 7 306 165 2.3 0 2.6 2.3 04/24/2006 07:20:00 16.9 1.5 20.2 12.6 16.7 1.5 20.2 13 15.3 1.7 20.6 10.3 313 6 307 165 2.4 0 2.6 2.3 04/24/2006 07:30:00 15.3 1.4 19.5 11.5 15.1 1.4 19.5 10.7 14.7 1.4 17.9 10.7 317 7 301 165 2.4 0 2.6 2.3 04/24/2006 07:40:00 14.9 1.4 18.7 11.8 14.6 1.3 18.3 11.8 14.3 1.6 18.3 10.3 318 7 320 165 2.5 0 2.8 2.3 04/24/2006 07:50:00 14.5 1.4 17.6 10.3 14.3 1.5 17.9 9.9 14.2 1.5 17.6 9.9 318 6 317 165 2.6 0 2.8 2.6 04/24/2006 08:00:00 13.7 1.5 17.6 9.5 13.5 1.5 17.6 9.1 13 1.4 16.8 9.5 318 7 305 165 2.6 0 2.8 2.6 04/24/2006 08:10:00 14.8 1.4 18.3 9.9 14.6 1.4 17.9 9.9 14.1 1.5 18.3 10.3 316 6 309 165 2.6 0 2.8 2.6 04/24/2006 08:20:00 15.1 1.6 18.3 10.7 14.9 1.7 18.3 10.7 13.6 1.7 17.2 8.8 313 8 306 165 2.7 0 2.8 2.6 04/24/2006 08:30:00 14.6 1.6 18.3 9.9 14.5 1.6 17.9 9.1 12.8 1.7 16.8 8.4 310 7 312 165 2.7 0 2.8 2.6 04/24/2006 08:40:00 14.1 1.4 17.6 10.7 13.9 1.5 17.2 10.7 12.3 1.4 15.6 8 311 7 294 165 2.9 0 3 2.8 04/24/2006 08:50:00 11.4 1.3 14.5 7.6 11.2 1.3 14.1 7.2 10 1.5 13.7 6.5 311 8 318 165 3 0 3.3 2.8 04/24/2006 09:00:00 11.2 1.5 14.5 6.8 11 1.5 14.5 6.5 9.9 1.5 13.3 5.7 311 8 309 165 3 0 3.3 2.8 04/24/2006 09:10:00 9.9 1.6 13.7 6.1 9.7 1.6 13.7 6.1 8.4 1.5 12.6 4.6 309 9 314 165 3.1 0 3.3 3 04/24/2006 09:20:00 6.5 1.7 12.2 3.4 6.4 1.7 11.5 3 5.6 1.5 10.7 3 303 14 307 165 3.3 0 3.5 3 04/24/2006 09:30:00 8.6 1.4 11.8 3.8 8.8 1.5 12.2 4.9 8.4 1.7 12.2 3.8 283 9 288 165 3.3 0 3.5 3.3 04/24/2006 09:40:00 7.5 1.6 10.7 4.2 7.6 1.5 10.7 4.2 7.2 1.5 10.7 3.8 283 8 287 165 3.6 0.3 4.3 3.3 04/24/2006 09:50:00 7.4 1.1 10.7 3.8 7.6 1.1 10.7 4.2 7.3 1.1 10.3 4.6 281 8 292 165 3.9 0 4.3 3.5 04/24/2006 10:00:00 6.7 1.3 10.3 3.8 6.6 1.3 10.7 3.8 5.6 1 8.4 3 296 9 311 165 3.8 0.1 4.3 3.5 04/24/2006 10:10:00 8.1 0.8 9.9 5.7 8.1 0.8 9.5 5.7 7.3 1.2 10.7 4.9 289 6 295 165 3.5 0 3.8 3.5 04/24/2006 10:20:00 6.9 1.1 9.5 4.2 6.9 1.1 9.9 4.2 5.9 1 9.1 3 292 9 298 165 3.8 0.1 4.3 3.5 04/24/2006 10:30:00 8.4 1.7 12.2 3.8 8.4 1.7 12.2 4.2 7.2 2 11.5 3 297 11 304 165 3.9 0 4.3 3.5 04/24/2006 10:40:00 8.3 1 10.7 5.7 8.3 1 10.7 5.7 6.9 1.1 11.1 4.9 299 9 301 165 4.1 0.1 4.5 3.8 04/24/2006 10:50:00 7.7 1 9.9 5.3 7.7 1 10.3 4.9 6.3 1 9.1 3.8 302 8 308 165 4.4 0.1 4.8 4 04/24/2006 11:00:00 6.4 1.2 9.5 3.8 6.4 1.2 9.5 3.8 5.5 1.2 8.4 2.6 295 12 290 165 4.1 0.1 4.5 3.5 04/24/2006 11:10:00 4.2 1.5 9.1 1.5 4.3 1.5 8.8 0.4 4.1 1.5 8.8 0.4 283 24 303 165 4.7 0.7 6.2 3.5 04/24/2006 11:20:00 5.6 1.5 9.9 1.9 6.3 1.5 9.9 2.6 6 1.3 8.8 3 266 17 244 165 5.8 0.3 6.5 5.2 04/24/2006 11:30:00 6.5 1.3 10.3 3.4 7.3 1.3 9.9 3.8 7 1.5 10.7 3.8 270 10 280 165 5.3 0.2 5.7 4.8 04/24/2006 11:40:00 6.2 1.1 8.8 3.4 7.2 1.1 9.9 4.6 6.9 1.3 9.9 3.8 267 10 272 165 5.3 0.2 6 4.8 04/24/2006 11:50:00 7.5 1.5 10.7 4.2 8 1.3 11.5 4.9 7.6 1.5 11.1 4.2 276 13 275 165 5.2 0.2 5.7 4.8 04/24/2006 12:00:00 6.3 1.4 9.9 3 7.1 1.2 10.3 4.2 6.6 1.2 9.5 3.4 260 13 243 165 5.4 0.1 5.7 4.8 04/24/2006 12:10:00 6 1 8.4 3 6.5 1 8.8 3.4 6 1.2 8.4 2.6 273 15 271 165 5.4 0.1 5.7 4.8 04/24/2006 12:20:00 5.9 1 8.8 3 6.4 1 8.4 3.8 5.9 1.1 8 3.4 277 12 277 165 5.4 0.3 5.7 4.5 04/24/2006 12:30:00 5.7 0.9 8 3.4 6.1 1 8.4 4.2 5.9 1 8 3.4 273 9 277 165 5.4 0.3 6 4.8 04/24/2006 12:40:00 5 1.1 8 1.9 5 1 8 2.6 4.5 1.3 8.8 1.9 292 15 272 165 5.3 0.2 5.7 5 04/24/2006 12:50:00 4.6 1.1 7.6 2.3 4.7 1 7.6 2.6 4.2 1 7.2 1.9 298 17 309 165 5.9 0 6.2 5.7 04/24/2006 13:00:00 4.5 1.1 7.2 1.5 4.7 1.1 7.2 2.3 4.5 1 6.8 2.3 261 18 239 165 5.7 0.4 6.5 5.2 04/24/2006 13:10:00 4.5 0.9 7.2 1.9 4.8 0.9 7.2 2.6 4.6 1 7.6 1.9 266 20 241 165 5.6 0.2 5.7 5.2 04/24/2006 13:20:00 4.7 1 7.2 2.3 5 0.9 7.6 2.6 4.5 1 7.2 1.9 280 11 282 165 5.6 0.2 6 5 04/24/2006 13:30:00 4.1 1.3 6.8 1.5 4.5 1.3 7.6 1.5 4.3 1.3 7.6 1.9 273 16 282 165 5.9 0.4 6.7 5.2 04/24/2006 13:40:00 4.1 1.1 7.2 1.5 4.7 1 7.2 2.3 4.4 1.1 8 1.9 259 19 286 165 6.6 0.2 7 6.2 04/24/2006 13:50:00 4.4 1 6.8 1.5 4.5 0.9 7.2 1.9 4.2 1 6.8 1.5 235 30 226 165 6.3 0.4 7 5.7 04/24/2006 14:00:00 3.6 1.2 6.1 1.1 4 1.3 7.2 1.9 3.7 1.2 6.8 1.1 271 16 295 165 6.2 0.3 7 5.7 04/24/2006 14:10:00 4.7 1 8 1.9 5 0.8 8 2.3 4.7 1 7.2 2.3 253 15 282 165 6 0 6.2 5.7 04/24/2006 14:20:00 4.3 0.8 6.5 2.3 4.6 0.8 6.8 2.3 4.3 0.9 6.5 1.5 275 17 282 165 6.2 0 6.7 6 04/24/2006 14:30:00 4.1 1.1 7.2 1.9 4.8 1.2 7.6 2.6 4.6 1.3 7.6 2.3 267 13 271 165 6.3 0.1 6.7 6 04/24/2006 14:40:00 4.5 0.8 6.5 2.3 4.6 1 7.2 2.3 4.3 1 6.5 2.3 296 19 305 165 6 0.2 6.7 5.5 04/24/2006 14:50:00 4.1 1 7.2 1.5 4.2 0.9 7.2 1.9 3.5 0.9 6.8 0.7 288 32 287 165 7.1 0.1 7.8 6.2 04/24/2006 15:00:00 4.2 0.9 6.8 2.3 4.2 0.9 6.8 2.3 3.5 0.8 5.3 1.9 300 15 298 165 6.8 0.1 7.5 6.2 04/24/2006 15:10:00 5.9 1.1 10.7 3.4 6 1.1 10.3 3.4 5 1 8 2.3 308 11 309 165 7 0.1 7.3 6.7 04/24/2006 15:20:00 6 1.1 8.4 2.6 6 1.1 8.4 2.6 5.1 1.1 7.2 1.5 308 10 307 165 6.1 0.3 7 5.7 04/24/2006 15:30:00 4.5 1 6.8 2.6 4.6 1 6.8 2.6 4.2 1.1 7.2 2.3 286 11 285 165 5.5 0.1 6 5.2 04/24/2006 15:40:00 5.3 1.5 8.4 1.9 5.4 1.3 8.4 2.3 4.9 1.5 8.8 1.9 297 18 303 165 5.6 0.2 6.2 5.2 04/24/2006 15:50:00 4.6 1.2 6.5 1.1 4.6 1.2 6.5 0.7 3.9 1 6.5 1.1 303 17 302 165 5.7 0.2 6 5.2 04/24/2006 16:00:00 3.8 1 6.1 0.7 3.8 1 6.1 0.4 3.2 0.9 5.7 0.4 292 35 310 165 5.9 0.2 6.2 5.5 04/24/2006 16:10:00 3.2 1.2 5.7 0.4 3.3 1.2 5.7 0.4 3.1 1.1 5.3 0.7 251 29 250 165 6.4 0.1 6.7 6 04/24/2006 16:20:00 4 1.2 6.1 1.1 4.1 1.2 6.1 1.1 4.1 1.2 6.8 1.5 220 12 214 165 5.7 0 6.2 5.5 04/24/2006 16:30:00 4.6 0.9 6.5 1.5 4.8 0.9 6.5 2.6 4.7 1 6.5 1.5 220 18 202 165 5.6 0.2 6.2 5.2 04/24/2006 16:40:00 3.8 1 6.1 1.9 4.2 0.7 6.1 1.9 3.9 0.8 5.7 2.3 247 18 237 165 5.7 0.1 6 5.5 04/24/2006 16:50:00 3.2 0.8 4.9 0.7 3.6 0.8 5.3 1.1 3.2 0.9 4.9 1.1 264 16 242 165 5.8 0.1 6.2 5.5 04/24/2006 17:00:00 3.7 0.8 6.5 1.9 4.3 0.8 6.1 2.6 4.2 0.8 6.1 2.6 259 11 275 165 5.5 0 5.7 5 04/24/2006 17:10:00 4.4 0.9 6.5 2.3 4.8 0.8 6.5 2.6 4.5 1 6.8 2.6 272 11 276 165 5.2 0.2 5.7 4.8 04/24/2006 17:20:00 5.1 1 7.6 2.6 5.2 1 7.6 2.6 4.9 1.2 8.4 1.9 287 9 287 165 4.5 0.1 5 3.8 04/24/2006 17:30:00 6.5 1 8.8 4.2 6.9 0.8 8.4 4.6 6.7 1 9.1 4.2 277 8 276 165 4.3 0.1 4.8 4.3 04/24/2006 17:40:00 5.2 0.8 7.2 3 5.9 0.8 7.6 3.4 5.7 1 8 3.4 273 10 271 165 4.4 0.1 4.8 4 04/24/2006 17:50:00 5.8 0.8 7.6 3.4 5.9 0.7 7.6 3.8 5.4 0.9 8 3 286 8 273 165 4.3 0.2 4.8 3.8 04/24/2006 18:00:00 4.6 0.7 6.1 2.6 4.6 0.7 6.1 2.3 4.1 0.8 6.1 1.5 289 9 272 165 4.2 0.1 4.5 3.8 04/24/2006 18:10:00 4.9 0.6 6.5 3 4.9 0.6 6.1 3 4.6 0.8 6.5 2.3 303 15 317 165 4.3 0.2 4.8 3.5 04/24/2006 18:20:00 5.6 0.6 7.6 4.2 5.5 0.6 7.2 4.2 5.4 0.6 7.2 3.8 316 6 306 165 4.3 0.2 4.8 3.8 04/24/2006 18:30:00 5.3 0.4 6.5 4.2 5.2 0.5 6.5 4.2 5 0.6 6.5 3.4 313 5 312 165 4 0.1 4.5 3.5 04/24/2006 18:40:00 4.4 0.5 6.1 3 4.4 0.5 6.1 3 4.3 0.5 5.7 3 316 6 316 165 4 0 4.3 3.5 04/24/2006 18:50:00 4.8 0.6 6.1 3 4.7 0.6 6.1 3 3.9 0.6 5.3 2.3 307 4 312 165 3.8 0.1 4.3 3.3 04/24/2006 19:00:00 4.2 0.5 6.1 2.6 4.2 0.5 5.7 2.6 3.6 0.6 4.9 1.9 306 7 312 165 3.5 0.2 3.8 3 04/24/2006 19:10:00 4.9 0.6 6.1 3 4.9 0.6 6.1 3 3.9 0.6 5.7 2.3 299 8 296 165 3.4 0 3.5 3 04/24/2006 19:20:00 5.3 0.3 6.1 4.2 5.3 0.4 6.1 4.2 4.8 0.6 5.7 3 309 5 306 165 3.2 0 3.5 3 04/24/2006 19:30:00 5.2 0.6 6.1 3.4 5.2 0.6 6.1 3 4.5 0.7 6.1 3 307 5 307 165 2.9 0 3.3 2.3 04/24/2006 19:40:00 4.9 0.4 5.7 3.8 4.9 0.4 5.7 3.4 3.9 0.5 4.9 2.6 305 4 307 165 2.6 0.1 2.8 1.8 04/24/2006 19:50:00 5.2 0.4 6.1 4.2 5.1 0.4 6.1 4.2 3.9 0.5 5.3 3 303 4 300 165 2.4 0 2.6 2.3 04/24/2006 20:00:00 5.2 0.4 6.5 4.2 5.1 0.4 6.5 4.2 4.1 0.5 5.3 3 306 5 301 165 2.1 0 2.3 1.8 04/24/2006 20:10:00 5 0.4 6.1 4.2 5 0.3 5.7 4.2 4 0.5 5.3 2.6 304 5 303 165 1.9 0 2.1 1.8 04/24/2006 20:20:00 4.5 0.4 5.3 3.4 4.6 0.4 5.7 3.4 4.2 0.5 5.7 3 285 6 293 165 1.7 0 1.8 1.6 04/24/2006 20:30:00 4.7 0.5 5.7 3.4 4.7 0.5 5.7 3.4 4.6 0.6 5.7 2.6 280 6 277 165 1.5 0.1 1.6 1.4 04/24/2006 20:40:00 4.3 0.4 5.3 3.4 4.3 0.4 5.3 3 3.9 0.5 4.9 2.6 287 4 288 165 1.4 0 1.6 1.4 04/24/2006 20:50:00 3.6 0.4 4.6 2.6 3.6 0.4 4.6 2.6 3.4 0.4 4.2 2.3 281 6 284 165 1.4 0 1.6 1.4 04/24/2006 21:00:00 2.7 0.4 3.4 1.9 2.8 0.4 3.4 1.5 2.7 0.5 3.8 1.5 283 5 279 165 1.4 0 1.4 1.4 04/24/2006 21:10:00 2.5 0.4 3.4 1.1 2.4 0.4 3.4 0.7 2.3 0.5 3 0.7 281 6 282 165 1.4 0 1.6 1.4 04/24/2006 21:20:00 1.9 0.4 2.6 0.7 1.9 0.4 2.6 0.7 2 0.3 3 0.4 264 16 274 165 1.4 0 1.6 1.4 04/24/2006 21:30:00 1.4 0.5 3 0.4 1.4 0.6 3 0.4 1.8 0.4 2.6 0.7 243 17 237 165 1.4 0 1.6 1.4 04/24/2006 21:40:00 1.2 0.3 1.9 0.4 1.1 0.4 2.3 0.4 1.5 0.3 2.3 0.7 251 15 270 165 1.4 0 1.6 1.4 04/24/2006 21:50:00 0.8 0.3 1.9 0.4 0.6 0.4 1.9 0.4 1 0.5 2.3 0.4 236 22 271 165 1.3 0 1.4 1.4 04/24/2006 22:00:00 0.9 0.4 1.9 0.4 0.7 0.4 1.9 0.4 1 0.4 2.3 0.4 250 22 207 165 1.3 0 1.6 1.1 04/24/2006 22:10:00 0.6 0.3 1.5 0.4 0.4 0.1 1.5 0.4 0.7 0.3 1.5 0.4 232 22 197 165 1.2 0 1.4 1.1 04/24/2006 22:20:00 0.7 0.4 1.5 0.4 0.5 0.3 1.5 0.4 0.7 0.4 1.9 0.4 202 23 208 165 1.1 0 1.4 0.9 04/24/2006 22:30:00 1.7 0.3 2.3 1.1 1.6 0.3 2.3 0.7 1.7 0.3 2.6 1.1 118 9 124 165 0.6 0 0.9 0.2 04/24/2006 22:40:00 1.5 0.2 2.3 0.7 1.4 0.3 2.3 0.7 1.5 0.2 2.3 0.7 114 9 104 165 0.4 0.1 0.7 0.2 04/24/2006 22:50:00 1.1 0.3 1.9 0.4 1 0.4 1.9 0.4 1.4 0.3 1.9 0.7 103 12 95 165 0.5 0 0.7 0.2 04/24/2006 23:00:00 0.5 0.3 1.5 0.4 0.4 0.2 1.5 0.4 0.5 0.3 1.5 0.4 95 0 95 165 0.8 0 0.9 0.7 04/24/2006 23:10:00 2.3 0.5 3 0.7 2.2 0.6 3 0.4 2.3 0.6 3 0.4 127 8 129 165 0.6 0 0.9 0.4 04/24/2006 23:20:00 2.4 0.2 2.6 1.9 2.3 0.2 2.6 1.9 2.3 0.2 2.6 1.5 133 0 134 165 0.5 0 0.7 0.2 04/24/2006 23:30:00 2.4 0.2 2.6 1.9 2.2 0.3 2.6 1.9 2.3 0.3 2.6 1.1 130 6 134 165 0.5 0 0.7 0.2 04/24/2006 23:40:00 2.7 0.2 3.4 2.3 2.6 0.2 3.4 2.3 2.6 0.2 3 2.3 122 3 120 165 0.2 0 0.7 0.2 04/24/2006 23:50:00 2.9 0.3 3.4 2.3 2.8 0.3 3.4 1.9 2.8 0.3 3.4 2.3 129 4 124 165 0.1 0 0.2 -0.1 04/25/2006 00:00:00 2.4 0.3 3 1.9 2.2 0.3 3 1.5 2.2 0.2 2.6 1.5 124 1 124 165 -0.1 0 0.2 -0.3 04/25/2006 00:10:00 2.2 0.3 2.6 1.5 2 0.3 2.6 1.1 2 0.3 2.6 1.5 119 5 121 165 -0.2 0 -0.1 -0.3 04/25/2006 00:20:00 2.7 0.3 3.4 1.9 2.6 0.3 3.4 1.9 2.6 0.4 3.8 1.9 112 8 99 165 -0.1 0 0.2 -0.3 04/25/2006 00:30:00 3.1 0.3 3.8 2.3 3.1 0.3 4.2 2.3 3.1 0.3 3.8 2.3 109 6 105 165 -0.2 0 -0.1 -0.3 04/25/2006 00:40:00 2.7 0.4 3.8 1.5 2.6 0.5 3.8 1.5 2.7 0.4 3.8 1.9 110 6 110 165 -0.1 0 0.2 -0.1 04/25/2006 00:50:00 2.1 0.4 3 1.5 2 0.4 3 0.7 2.2 0.3 3 1.5 89 14 63 165 -0.2 0 -0.1 -0.3 04/25/2006 01:00:00 1.9 0.3 2.6 1.1 1.8 0.4 2.6 0.7 2 0.4 2.6 1.5 99 15 68 165 -0.2 0.1 -0.1 -0.5 04/25/2006 01:10:00 2.1 0.3 2.6 1.5 2 0.3 2.6 1.5 2.2 0.3 3 1.5 98 8 108 165 -0.3 0 -0.3 -0.5 04/25/2006 01:20:00 1.9 0.4 2.6 1.1 1.8 0.4 2.6 0.7 2.1 0.3 2.6 1.5 94 9 100 165 -0.3 0 -0.1 -0.5 04/25/2006 01:30:00 2.1 0.2 2.6 1.5 2 0.3 2.6 1.5 2 0.3 2.6 1.5 81 15 98 165 -0.3 0 -0.3 -0.5 04/25/2006 01:40:00 1.3 0.4 2.6 0.4 0.9 0.6 2.6 0.4 1.5 0.4 2.6 0.7 37 8 39 165 -0.5 0 -0.3 -0.5 04/25/2006 01:50:00 2.1 0.6 3 0.7 1.9 0.7 3 0.4 2 0.5 3 0.4 98 27 106 165 -0.5 0 -0.3 -0.8 04/25/2006 02:00:00 1.3 0.5 2.6 0.4 0.7 0.5 2.6 0.4 1 0.5 2.6 0.4 139 10 122 165 -0.7 0 -0.5 -0.8 04/25/2006 02:10:00 0.8 0.4 1.5 0.4 0.5 0.3 1.5 0.4 0.5 0.3 1.1 0.4 112 22 94 165 -0.9 0 -0.8 -1 04/25/2006 02:20:00 1.8 0.5 3 0.4 1.5 0.7 2.6 0.4 1.6 0.6 2.6 0.4 101 12 100 165 -0.8 0 -0.5 -0.8 04/25/2006 02:30:00 2.4 0.2 3 1.9 2.4 0.3 3 1.5 2.4 0.3 3 1.9 108 7 112 165 -0.7 0 -0.5 -0.8 04/25/2006 02:40:00 1.6 0.4 2.6 0.4 1.5 0.5 2.3 0.4 1.7 0.5 2.3 0.7 96 7 107 165 -0.6 0 -0.5 -0.8 04/25/2006 02:50:00 1.6 0.7 2.6 0.4 1.2 0.8 2.6 0.4 1.8 0.6 2.6 0.7 45 23 30 165 -0.6 0.2 -0.5 -1 04/25/2006 03:00:00 1.7 0.4 2.6 0.7 1.5 0.5 2.6 0.4 1.8 0.5 2.6 0.7 81 26 39 165 -0.9 0 -0.8 -1.2 04/25/2006 03:10:00 1.6 0.4 2.6 1.1 1.4 0.5 2.6 0.4 1.8 0.5 3 1.1 70 18 49 165 -0.8 0 -0.5 -1 04/25/2006 03:20:00 2.2 0.3 2.6 1.1 2 0.4 2.6 0.4 2.3 0.3 3 1.5 45 7 39 165 -0.9 0 -0.8 -1 04/25/2006 03:30:00 1.9 0.3 2.6 1.1 1.7 0.3 2.3 0.7 2 0.3 2.6 1.1 71 12 70 165 -0.7 0 -0.5 -0.8 04/25/2006 03:40:00 2.1 0.7 3 0.7 1.7 0.7 3 0.4 2.4 0.6 3.4 1.5 45 26 29 165 -0.8 0.1 -0.5 -1.2 04/25/2006 03:50:00 2.5 0.2 3.4 1.9 2.1 0.3 3.4 1.5 2.6 0.2 3 2.3 23 6 40 165 -1.1 0 -0.8 -1.2 04/25/2006 04:00:00 2 0.3 2.6 1.1 1.8 0.3 2.6 0.7 2.1 0.2 2.6 1.5 43 10 36 165 -0.9 0 -0.8 -1.2 04/25/2006 04:10:00 2.1 0.3 3 1.5 2 0.3 2.6 1.1 2.2 0.2 3 1.9 54 6 73 165 -0.9 0 -0.5 -1 04/25/2006 04:20:00 2 0.3 2.6 0.7 1.8 0.4 2.6 0.4 2.2 0.2 2.6 1.5 55 7 52 165 -0.8 0 -0.5 -1 04/25/2006 04:30:00 2.2 0.3 2.6 1.5 2 0.3 2.6 1.1 2.3 0.3 3 1.9 55 5 52 165 -0.9 0 -0.8 -1 04/25/2006 04:40:00 2.2 0.4 3.4 1.5 2 0.4 3 1.1 2.4 0.4 3.4 1.5 68 15 70 165 -0.8 0 -0.5 -0.8 04/25/2006 04:50:00 2.1 0.4 3 1.1 1.9 0.4 3 0.7 2.4 0.3 3.4 1.5 64 8 73 165 -0.9 0 -0.8 -1 04/25/2006 05:00:00 2.3 0.3 3 1.9 2.1 0.3 2.6 1.5 2.4 0.3 3 1.9 42 9 44 165 -0.9 0 -0.8 -1.2 04/25/2006 05:10:00 2.2 0.2 3 1.9 1.9 0.3 2.6 1.1 2.3 0.2 2.6 1.9 27 4 29 165 -0.9 0 -0.8 -1.2 04/25/2006 05:20:00 1.7 0.3 2.3 0.7 1.2 0.4 1.9 0.4 1.7 0.3 2.3 1.1 30 9 22 165 -0.9 0 -0.8 -1 04/25/2006 05:30:00 1.2 0.3 2.3 0.4 0.6 0.4 2.3 0.4 1.3 0.4 2.3 0.7 80 10 49 165 -0.6 0 -0.5 -0.8 04/25/2006 05:40:00 1.8 0.3 2.3 1.1 1.4 0.4 2.3 0.4 1.9 0.4 2.6 0.7 64 11 65 165 -0.5 0 -0.5 -0.8 04/25/2006 05:50:00 2.5 0.2 3 1.9 1.8 0.4 2.3 0.7 2.6 0.3 3 1.9 21 8 23 165 -0.7 0 -0.5 -0.8 04/25/2006 06:00:00 2.2 0.2 2.6 1.9 1.8 0.2 2.3 1.1 2.3 0.2 2.6 1.9 24 4 19 165 -0.7 0 -0.5 -0.8 04/25/2006 06:10:00 2.2 0.2 2.6 1.9 1.8 0.2 2.3 1.1 2.4 0.2 2.6 1.9 28 2 27 165 -0.5 0 -0.3 -0.8 04/25/2006 06:20:00 2.4 0.2 3 1.9 1.9 0.4 2.6 0.7 2.6 0.2 3 2.3 25 6 33 165 -0.3 0 -0.3 -0.5 04/25/2006 06:30:00 3.1 0.3 3.8 2.6 2.7 0.3 3.4 2.3 3.3 0.3 3.8 2.6 28 3 25 165 -0.3 0 -0.1 -0.5 04/25/2006 06:40:00 3.3 0.2 3.8 3 2.7 0.3 3.4 2.3 3.5 0.2 4.2 3 20 2 20 165 -0.3 0 -0.1 -0.5 04/25/2006 06:50:00 3.1 0.3 3.8 2.3 2.7 0.3 3.4 2.3 3.2 0.3 3.8 2.3 24 5 18 165 -0.2 0 -0.1 -0.3 04/25/2006 07:00:00 2.6 0.2 3 2.3 2.4 0.2 3 1.9 2.6 0.2 3.4 2.3 43 6 35 165 0 0 0.2 -0.3 04/25/2006 07:10:00 2.9 0.2 3.4 2.3 2.5 0.2 3 1.9 2.9 0.3 3.4 1.9 30 3 29 165 0.1 0 0.2 -0.1 04/25/2006 07:20:00 2.3 0.5 3.4 1.1 2 0.6 3 0.4 2.6 0.5 3.4 1.9 46 15 36 165 0.1 0 0.2 -0.1 04/25/2006 07:30:00 1.8 0.4 3 0.7 1.3 0.5 2.6 0.4 1.9 0.4 2.6 0.4 74 13 50 165 0.3 0 0.7 -0.1 04/25/2006 07:40:00 2.7 0.4 3.8 1.9 2.4 0.4 3.4 1.5 2.7 0.4 3.8 1.5 55 10 43 165 0.5 0 0.9 0.2 04/25/2006 07:50:00 3.1 0.3 3.8 2.3 2.9 0.4 3.4 2.3 3.2 0.4 3.8 2.3 38 4 40 165 0.4 0 0.7 0.2 04/25/2006 08:00:00 2.7 0.3 3.4 1.9 2.3 0.4 3.4 1.5 2.7 0.3 3.4 1.9 37 7 44 165 0.5 0 0.7 0.2 04/25/2006 08:10:00 2.5 0.5 3.4 1.5 2.1 0.5 3.4 0.7 2.5 0.4 3.4 1.5 47 9 42 165 0.4 0 0.7 0.2 04/25/2006 08:20:00 2.1 0.3 2.6 1.5 1.8 0.4 2.6 0.7 2.2 0.3 3 1.5 55 5 50 165 0.4 0 0.7 0.2 04/25/2006 08:30:00 2.3 0.4 3 1.5 2 0.5 3 0.7 2.2 0.4 3 1.5 55 9 58 165 0.2 0 0.7 0.2 04/25/2006 08:40:00 3.4 0.5 4.2 2.3 3 0.5 3.8 1.5 3.4 0.5 4.2 2.3 31 5 34 165 0.2 0 0.4 -0.1 04/25/2006 08:50:00 3.6 0.3 4.2 3 3.3 0.3 4.2 2.6 3.7 0.3 4.2 3 30 3 25 165 0.2 0 0.7 0.2 04/25/2006 09:00:00 2.6 0.4 3.4 1.9 2.3 0.4 3.4 1.5 2.5 0.4 3.8 1.5 43 7 32 165 0.4 0 0.7 0.2 04/25/2006 09:10:00 1.9 0.5 3 0.7 1.4 0.6 3 0.4 1.7 0.4 2.6 0.7 59 16 66 165 0.4 0 0.7 0.2 04/25/2006 09:20:00 2 0.7 4.2 0.7 1.5 0.9 3.8 0.4 1.7 0.8 3.8 0.4 89 17 90 165 0.8 0.1 1.1 0.2 04/25/2006 09:30:00 2.7 0.6 4.6 1.1 2.5 0.7 4.6 0.7 2.6 0.6 4.9 1.1 116 20 94 165 1.2 0.1 1.4 0.9 04/25/2006 09:40:00 2.2 0.6 4.2 0.4 1.8 0.8 3.8 0.4 2.1 0.6 4.2 0.4 120 15 123 165 1.7 0.3 2.3 1.4 04/25/2006 09:50:00 2.2 0.6 4.2 1.1 1.9 0.8 4.2 0.4 2.2 0.7 4.2 0.4 144 17 129 165 2.4 0 2.8 2.1 04/25/2006 10:00:00 2.2 0.7 3.8 0.7 1.8 0.9 3.8 0.4 2.2 0.7 4.2 0.7 142 19 117 165 2.5 0.3 3 2.1 04/25/2006 10:10:00 3 0.7 5.3 1.5 2.8 0.8 5.3 0.7 3 0.8 4.9 1.5 131 18 144 165 2.5 0.3 2.8 1.8 04/25/2006 10:20:00 4.1 0.6 6.1 2.6 3.8 0.7 6.1 2.3 4.1 0.7 6.5 2.3 143 9 141 165 2 0 2.3 1.8 04/25/2006 10:30:00 3.1 0.7 4.9 1.5 2.8 0.8 4.9 1.1 3.2 0.8 5.3 1.1 149 11 140 165 1.8 0.1 2.3 1.4 04/25/2006 10:40:00 3.7 0.6 5.3 1.5 3.5 0.6 4.9 1.1 3.7 0.6 5.7 2.3 153 10 164 165 1.8 0.3 2.6 1.4 04/25/2006 10:50:00 4.1 0.6 5.7 2.6 3.9 0.7 6.5 2.3 4.1 0.7 6.1 2.3 145 8 150 165 2.7 0.3 3.3 2.3 04/25/2006 11:00:00 2.4 0.8 4.6 0.7 2.1 1 4.6 0.4 2.4 0.8 4.6 0.7 139 18 136 165 2.9 0 3 2.3 04/25/2006 11:10:00 3.2 0.6 4.6 1.9 3.1 0.6 4.9 1.5 3.2 0.6 4.6 1.5 148 13 158 165 3.5 0.2 3.8 2.8 04/25/2006 11:20:00 3.6 0.8 5.7 1.9 3.3 0.8 5.7 1.1 3.6 0.8 5.7 1.9 138 12 110 165 3.1 0.4 3.8 2.3 04/25/2006 11:30:00 3.3 1 5.7 1.1 3 1.1 5.7 0.4 3.2 1 6.1 0.4 126 15 135 165 3.5 0.2 3.8 2.3 04/25/2006 11:40:00 3.8 0.8 5.3 1.9 3.6 0.8 5.7 1.5 3.8 0.8 6.1 1.9 136 14 124 165 3.5 0.3 4.3 2.8 04/25/2006 11:50:00 4 1 7.6 1.5 3.8 1.1 7.6 0.7 4 1 8 1.9 139 14 103 165 3 0.2 3.5 2.3 04/25/2006 12:00:00 5.4 0.8 7.6 3.4 5.4 0.9 7.6 3.4 5.3 0.9 7.6 3.4 131 15 118 165 2.6 0 2.8 2.1 04/25/2006 12:10:00 6 0.5 7.2 3.8 6 0.6 7.2 3.8 5.9 0.7 8 3 132 11 121 165 2.8 0.1 3 2.3 04/25/2006 12:20:00 6.7 0.6 8 4.9 6.7 0.6 8 4.9 6.7 0.7 8 4.6 134 10 133 165 2.1 0.2 2.8 1.8 04/25/2006 12:30:00 5.1 1.3 8.4 1.9 5 1.3 8.4 1.9 5.3 1.3 8.4 2.3 170 11 166 165 1.5 0.2 2.1 1.4 04/25/2006 12:40:00 5.2 1.1 7.6 0.7 5 1.1 7.2 1.1 5.2 1.2 7.6 1.1 158 19 167 165 1.4 0.1 1.8 1.4 04/25/2006 12:50:00 5.9 0.6 7.6 4.6 5.8 0.6 7.2 4.2 6 0.7 7.6 4.6 160 8 162 165 2.5 0.2 2.8 1.8 04/25/2006 13:00:00 6.1 0.7 7.6 3.8 6 0.7 7.6 3.8 6.3 0.7 7.6 4.2 149 7 157 165 1.8 0.1 2.6 1.6 04/25/2006 13:10:00 4.9 0.4 6.1 3.8 4.8 0.4 6.1 3.8 4.9 0.4 6.5 3.8 146 6 154 165 2.5 0.1 3 1.8 04/25/2006 13:20:00 5.4 0.7 6.8 3.4 5.3 0.7 6.8 3 5.3 0.6 6.8 3.4 148 8 147 165 3.2 0.1 3.5 2.8 04/25/2006 13:30:00 4.9 0.5 6.5 3.4 4.8 0.5 6.8 3.4 4.9 0.4 6.1 3.8 143 6 139 165 3.2 0.2 3.8 2.8 04/25/2006 13:40:00 4.8 0.8 7.2 3 4.8 0.7 6.8 3 4.8 0.8 6.8 3 146 7 148 165 3.4 0.2 3.5 2.6 04/25/2006 13:50:00 5.5 0.7 7.2 3.8 5.4 0.7 7.2 3.8 5.5 0.6 7.2 3.8 144 9 154 165 3.3 0.2 3.8 2.6 04/25/2006 14:00:00 5.9 0.6 7.2 4.2 5.9 0.6 7.6 4.2 5.8 0.7 7.6 4.2 140 9 139 165 3.6 0.2 4.3 2.8 04/25/2006 14:10:00 6.9 0.8 9.1 4.9 6.9 0.9 9.1 4.9 6.9 0.9 8.8 4.9 142 8 135 165 3.8 0.1 4.3 3.5 04/25/2006 14:20:00 7.9 0.5 9.5 6.1 7.9 0.5 9.9 6.1 7.8 0.6 9.5 6.1 138 4 139 165 4 0.1 4.3 3.5 04/25/2006 14:30:00 8.1 0.6 9.5 6.5 8.1 0.6 9.5 6.5 8.2 0.7 9.9 5.7 142 5 139 165 3.8 0.5 4.5 2.8 04/25/2006 14:40:00 8.3 0.4 9.5 7.2 8.3 0.4 9.5 7.2 8.3 0.5 9.5 6.8 141 5 139 165 3 0.1 3.3 2.6 04/25/2006 14:50:00 8.2 0.6 9.5 6.5 8.2 0.6 9.5 6.8 8 0.7 9.9 5.7 138 5 141 165 2.9 0 3 2.3 04/25/2006 15:00:00 7.9 0.5 9.5 6.5 8 0.5 9.5 6.5 7.9 0.7 9.5 6.1 138 6 129 165 2.8 0 3 2.3 04/25/2006 15:10:00 8.4 0.6 9.5 6.8 8.4 0.6 9.9 6.8 8.4 0.7 9.9 6.1 138 4 132 165 2.9 0.1 3.3 2.8 04/25/2006 15:20:00 8.1 0.7 9.5 6.1 8.1 0.8 9.5 6.1 8.2 0.7 9.9 6.1 141 5 137 165 3 0 3.3 3 04/25/2006 15:30:00 7.5 0.6 8.8 5.7 7.6 0.6 8.8 5.7 7.6 0.6 9.1 6.1 139 6 142 165 3.7 0.2 4.3 3.3 04/25/2006 15:40:00 8.1 0.5 9.5 6.8 8.2 0.5 9.5 6.8 8.2 0.6 9.9 6.5 140 5 148 165 3.4 0.1 3.8 2.8 04/25/2006 15:50:00 8.5 0.4 9.5 7.2 8.5 0.4 9.5 7.2 8.6 0.5 9.9 6.1 141 3 145 165 3.1 0.2 3.5 2.8 04/25/2006 16:00:00 8.4 0.6 10.3 6.8 8.5 0.6 10.3 6.8 8.5 0.7 10.7 6.8 139 3 137 165 3 0 3.3 2.6 04/25/2006 16:10:00 7.8 0.7 9.5 4.9 7.9 0.8 9.5 4.9 7.8 0.9 10.3 5.3 131 6 129 165 2.4 0 2.8 2.3 04/25/2006 16:20:00 7.2 0.6 8.4 4.9 7.3 0.7 8.4 5.3 7 0.8 8.4 4.6 129 5 128 165 2.4 0.1 2.8 2.3 04/25/2006 16:30:00 7.1 0.8 8.8 4.9 7.1 0.8 9.1 4.9 7 0.8 8.4 4.6 133 6 130 165 2.9 0 3.3 2.6 04/25/2006 16:40:00 7 0.5 8.4 5.3 7.1 0.6 8.4 5.7 7.1 0.6 8.4 4.9 137 7 128 165 2.9 0 3 2.6 04/25/2006 16:50:00 7.3 0.7 9.1 5.3 7.4 0.7 9.1 5.3 7.3 0.8 9.5 4.9 134 6 140 165 2.9 0 3 2.8 04/25/2006 17:00:00 6.4 0.7 8.4 4.2 6.6 0.7 8.4 4.2 6.5 0.7 8 3.8 133 11 146 165 3.8 0.2 4.3 3 04/25/2006 17:10:00 6.7 0.8 8.8 4.6 6.8 0.8 8.8 4.9 6.7 0.8 8.8 4.9 131 7 132 165 3.7 0 4 3.5 04/25/2006 17:20:00 6.9 0.6 8.4 4.9 7 0.6 8.4 4.9 6.9 0.7 8.8 5.3 133 6 136 165 3.6 0.1 4 3.3 04/25/2006 17:30:00 6.5 0.6 8.4 4.9 6.6 0.7 8.8 5.3 6.5 0.8 9.1 4.6 133 7 133 165 3.2 0.1 3.5 2.8 04/25/2006 17:40:00 7 0.6 8.4 5.3 7.2 0.6 8.4 5.3 6.9 0.7 8.4 4.6 129 5 122 165 2.6 0.1 3 2.6 04/25/2006 17:50:00 7.2 0.6 8.8 5.7 7.3 0.6 8.8 5.7 7.1 0.7 9.1 5.3 133 5 139 165 2.5 0 2.8 2.3 04/25/2006 18:00:00 7.9 0.7 9.5 6.5 8 0.6 9.5 6.5 8 0.7 10.3 6.1 139 5 144 165 2.4 0 2.8 2.3 04/25/2006 18:10:00 6.5 0.9 8.8 4.9 6.5 0.9 8.8 4.9 6.4 1 8.8 4.6 136 5 135 165 2.1 0 2.3 1.8 04/25/2006 18:20:00 5.1 0.5 6.5 4.2 5.2 0.5 6.8 4.2 5 0.4 6.1 3.8 131 6 144 165 2.3 0.2 2.8 1.8 04/25/2006 18:30:00 5.4 0.6 7.6 3 5.4 0.6 7.6 3.4 5.3 0.7 7.2 3.4 134 7 140 165 2.7 0.1 3 2.3 04/25/2006 18:40:00 5.2 0.4 6.5 3.8 5.3 0.4 6.5 4.2 5.1 0.4 6.1 4.2 134 7 136 165 2.4 0 2.6 2.3 04/25/2006 18:50:00 4.9 0.4 6.5 3.8 4.9 0.4 6.5 3.4 4.8 0.4 6.1 3.4 138 6 136 165 2.4 0 2.6 2.3 04/25/2006 19:00:00 4.4 0.5 5.7 3 4.4 0.5 5.7 2.6 4.3 0.6 6.1 3 142 6 138 165 2.4 0 2.6 2.3 04/25/2006 19:10:00 5.3 1.1 7.6 2.6 5.1 1.1 7.6 2.6 5.4 1.2 8.4 3 156 9 164 165 1.9 0.4 2.6 1.4 04/25/2006 19:20:00 6.2 0.7 7.6 4.2 6.2 0.7 7.6 4.2 6.3 0.7 7.6 4.2 155 5 153 165 1.2 0 1.4 1.1 04/25/2006 19:30:00 6.1 0.5 7.2 4.6 6.1 0.5 7.6 4.6 6.1 0.6 7.6 3.8 157 7 150 165 1 0.1 1.4 0.9 04/25/2006 19:40:00 5.9 0.9 8 4.2 6 0.9 8 4.2 5.7 1 8 3 161 11 162 165 0.8 0 0.9 0.7 04/25/2006 19:50:00 3.7 0.6 5.3 1.9 3.8 0.6 5.3 1.9 3.3 0.6 4.9 1.9 156 10 165 165 0.8 0 0.9 0.7 04/25/2006 20:00:00 4.8 0.7 6.1 2.3 4.7 0.7 6.1 2.3 4.5 0.6 6.1 2.6 148 8 153 165 1 0 1.4 0.9 04/25/2006 20:10:00 3.6 1.1 5.3 0.7 3.6 1.1 5.7 0.7 3.5 1.1 5.3 0.4 142 17 159 165 1.2 0 1.4 0.9 04/25/2006 20:20:00 4.4 0.5 5.3 3.4 4.4 0.5 5.3 3.4 4.3 0.5 5.7 3 151 5 154 165 1.4 0 1.6 1.1 04/25/2006 20:30:00 6.4 1.9 10.3 3.4 6.4 1.8 9.9 3.4 6.2 1.8 9.9 3 151 6 148 165 1.4 0 1.6 1.4 04/25/2006 20:40:00 8.6 0.6 10.7 6.8 8.6 0.7 10.7 6.5 8.3 0.8 10.7 6.1 153 6 154 165 1.2 0 1.4 0.9 04/25/2006 20:50:00 6.2 0.9 8.8 4.6 6.1 1 8.8 4.2 5.9 0.9 8.8 4.2 147 9 139 165 0.8 0 1.1 0.7 04/25/2006 21:00:00 4.8 0.6 6.8 3 4.8 0.6 6.5 3 4.5 0.7 6.5 3 141 12 147 165 0.8 0 1.1 0.7 04/25/2006 21:10:00 4.4 0.7 6.1 2.3 4.4 0.7 6.1 2.6 4.2 0.7 6.1 2.6 137 7 130 165 0.9 0 1.1 0.7 04/25/2006 21:20:00 4.8 0.6 6.1 3 4.9 0.6 6.1 3.4 4.6 0.7 6.1 3 131 8 142 165 1.1 0 1.4 0.9 04/25/2006 21:30:00 5.2 0.6 6.5 3.4 5.4 0.6 6.5 3.8 5.2 0.6 6.5 3.8 122 6 128 165 1.2 0 1.4 1.1 04/25/2006 21:40:00 4.5 0.4 5.3 3.4 4.7 0.4 5.7 3.8 4.6 0.4 5.3 3.4 128 6 127 165 1.2 0 1.4 0.9 04/25/2006 21:50:00 5.3 0.6 6.8 3.8 5.4 0.6 7.2 3.8 5.3 0.6 6.5 3.8 133 7 125 165 1.4 0 1.6 1.1 04/25/2006 22:00:00 5.9 0.5 7.6 4.2 6.1 0.6 7.6 4.6 6 0.5 7.6 4.9 129 6 125 165 1.4 0 1.6 1.4 04/25/2006 22:10:00 6.5 0.4 7.6 5.3 6.6 0.4 8 5.3 6.5 0.4 7.6 5.3 133 4 125 165 1.5 0 1.6 1.4 04/25/2006 22:20:00 6.6 0.8 8.8 4.9 6.7 0.7 8.8 5.3 6.7 0.7 9.1 5.7 133 5 141 165 1.5 0 1.6 1.4 04/25/2006 22:30:00 5.9 1.2 9.1 3 5.9 1.2 8.8 2.6 5.9 1.2 8.4 2.3 139 13 139 165 1.4 0 1.6 1.4 04/25/2006 22:40:00 6.3 0.6 7.2 4.6 6.3 0.6 8 4.9 6.2 0.6 8 4.6 141 7 152 165 1.5 0 1.6 1.4 04/25/2006 22:50:00 6 0.5 7.2 4.6 6 0.5 6.8 4.9 5.8 0.6 7.2 3.4 135 4 135 165 1.2 0 1.6 1.1 04/25/2006 23:00:00 6.4 0.6 8 4.6 6.5 0.6 8.4 4.9 6.2 0.7 8.4 4.6 131 5 122 165 1.3 0 1.6 1.1 04/25/2006 23:10:00 6.9 0.6 8.4 4.9 7 0.6 8.4 5.3 6.6 0.7 8 4.6 130 6 128 165 1.3 0 1.6 1.1 04/25/2006 23:20:00 6.3 0.5 8 4.9 6.4 0.5 8 4.9 6.3 0.6 8 4.9 132 6 143 165 1 0 1.4 0.9 04/25/2006 23:30:00 6.1 0.5 7.2 4.6 6.1 0.5 7.6 4.6 6 0.5 7.2 4.6 143 6 149 165 1.2 0 1.4 0.9 04/25/2006 23:40:00 5.3 0.6 7.2 3.8 5.3 0.6 7.2 3.8 5.2 0.6 7.2 3 137 9 116 165 1.4 0 1.6 0.9 04/25/2006 23:50:00 6.4 1.7 10.3 3.8 6.4 1.7 10.7 3.8 6.4 1.8 10.7 3.8 149 9 163 165 1.4 0 1.6 1.4 04/26/2006 00:00:00 7 0.9 8.8 4.9 7 0.9 9.1 4.9 6.9 1 9.1 4.6 163 5 164 165 1.2 0 1.6 0.9 04/26/2006 00:10:00 4.2 0.6 6.1 2.6 4.2 0.6 6.1 2.6 4 0.8 6.5 2.3 143 13 160 165 1 0 1.1 0.9 04/26/2006 00:20:00 4.6 0.5 6.1 3.4 4.6 0.5 6.5 3.4 4.3 0.5 6.1 2.6 138 6 139 165 1.2 0.1 1.4 0.9 04/26/2006 00:30:00 4.5 0.6 6.8 3.4 4.4 0.6 6.1 3 4.5 0.6 6.5 3 142 12 158 165 1.4 0 1.6 1.4 04/26/2006 00:40:00 4.8 0.6 6.8 3 4.8 0.7 6.5 3 4.6 0.6 6.1 3 144 11 129 165 1.4 0 1.6 1.4 04/26/2006 00:50:00 3.9 0.4 4.9 3 3.8 0.4 4.9 2.6 3.8 0.4 4.9 3 141 6 144 165 1.2 0 1.4 1.1 04/26/2006 01:00:00 5.3 0.7 6.8 3.8 5.3 0.7 6.8 3.8 5.1 0.6 6.5 3.8 139 5 138 165 1.3 0 1.4 1.1 04/26/2006 01:10:00 5.3 0.7 7.2 3.4 5.2 0.7 7.2 3 5.2 0.7 7.6 2.6 140 8 135 165 1.4 0 1.6 1.4 04/26/2006 01:20:00 6.3 2.2 11.1 2.6 6.3 2.3 10.7 2.6 6.1 2.3 11.5 2.3 141 15 144 165 1.5 0 1.6 1.4 04/26/2006 01:30:00 8.3 0.8 10.7 6.1 8.3 0.8 11.1 6.1 8.2 0.8 10.3 6.5 131 8 123 165 1 0 1.4 0.9 04/26/2006 01:40:00 7.2 0.6 8.8 5.7 7.2 0.5 8.8 6.1 7 0.6 8.4 5.3 138 7 145 165 1.2 0 1.4 0.9 04/26/2006 01:50:00 6.8 0.7 8.4 5.3 6.8 0.8 8.4 5.3 6.8 0.7 8.4 4.9 134 8 128 165 1.3 0 1.4 1.1 04/26/2006 02:00:00 6.1 0.9 8.8 4.2 6.1 1 9.1 4.2 6 1 9.5 3.8 125 9 119 165 1.4 0 1.6 1.4 04/26/2006 02:10:00 8.9 1.6 11.8 3.8 8.9 1.5 11.8 3.8 8.9 1.7 11.5 3.4 147 7 158 165 1.2 0.2 1.6 0.9 04/26/2006 02:20:00 7.2 0.8 9.5 5.7 7.3 0.8 9.5 5.7 7.2 0.8 9.5 4.9 131 6 139 165 0.8 0 1.1 0.7 04/26/2006 02:30:00 6.7 0.5 8 4.9 6.7 0.5 8.4 5.3 6.7 0.5 8.4 4.9 131 5 134 165 0.9 0 1.1 0.9 04/26/2006 02:40:00 7.1 0.8 9.1 5.3 7.1 0.8 9.1 5.7 7 0.7 9.1 5.7 133 6 139 165 1.1 0 1.4 0.9 04/26/2006 02:50:00 7.7 0.8 9.9 5.7 7.8 0.8 9.9 5.7 7.7 0.9 10.3 5.3 131 7 126 165 1.4 0 1.6 1.4 04/26/2006 03:00:00 8 0.9 10.3 5.7 8.1 0.9 10.7 5.7 8.2 1 10.7 5.7 133 17 125 165 1.6 0 1.8 1.4 04/26/2006 03:10:00 6.9 0.6 8.8 5.3 6.9 0.6 8.8 5.3 6.9 0.6 8.8 5.7 153 5 157 165 1.3 0 1.6 1.1 04/26/2006 03:20:00 4.9 1 8 3 5 1 7.6 3.4 4.8 0.9 6.8 3 141 8 143 165 1.4 0 1.6 1.4 04/26/2006 03:30:00 8.4 1 10.7 4.6 8.5 0.9 10.7 4.9 8.4 1.2 10.7 5.3 143 14 136 165 1.6 0 1.8 1.4 04/26/2006 03:40:00 7.3 0.5 8.4 6.1 7.3 0.5 8.4 6.1 7.5 0.5 8.8 6.1 152 3 153 165 1.5 0 1.6 1.4 04/26/2006 03:50:00 7 0.5 8 5.3 7.1 0.5 8 5.3 6.9 0.5 8 5.3 142 5 150 165 1.6 0 1.8 1.4 04/26/2006 04:00:00 8.1 0.5 9.5 6.5 8.3 0.5 9.9 6.8 8.2 0.6 9.9 6.8 131 6 132 165 1.5 0.1 1.8 1.1 04/26/2006 04:10:00 7.6 0.7 9.5 6.1 7.8 0.7 9.5 6.1 7.7 0.8 10.3 5.3 133 6 128 165 1.2 0 1.4 1.1 04/26/2006 04:20:00 7.3 0.7 8.8 5.7 7.5 0.7 9.1 5.7 7.3 0.7 8.8 5.3 125 3 129 165 1.4 0 1.6 1.4 04/26/2006 04:30:00 6.4 0.3 7.2 5.3 6.6 0.4 7.6 5.3 6.4 0.4 7.2 4.9 120 3 124 165 1.5 0 1.8 1.4 04/26/2006 04:40:00 7.1 0.5 8 6.1 7.4 0.5 8.4 6.1 7.1 0.5 8.4 5.3 117 3 115 165 1.7 0 1.8 1.6 04/26/2006 04:50:00 6.5 0.3 7.2 5.7 6.7 0.3 7.6 5.7 6.5 0.5 7.6 4.6 114 4 114 165 1.7 0 1.8 1.6 04/26/2006 05:00:00 7.4 1.7 13 4.9 7.5 1.7 13 4.9 7.4 1.7 11.8 4.2 117 10 123 165 1.7 0 1.8 1.6 04/26/2006 05:10:00 9.4 1 11.8 6.5 9.5 1 11.8 6.8 9.3 1 11.8 6.1 124 7 128 165 1.5 0.1 1.8 1.4 04/26/2006 05:20:00 9.8 1.1 12.6 7.6 9.9 1.1 12.6 7.2 9.7 1 12.6 7.2 123 7 121 165 1.1 0 1.4 0.9 04/26/2006 05:30:00 9.8 0.5 10.7 8 10 0.5 11.1 8.4 9.7 0.7 11.5 7.2 121 4 118 165 1.2 0 1.4 0.9 04/26/2006 05:40:00 9.8 0.7 11.5 7.6 10 0.7 11.8 7.6 9.8 0.8 11.5 7.2 121 4 128 165 1.4 0 1.6 1.4 04/26/2006 05:50:00 8.4 1 10.7 5.7 8.6 1 11.1 5.7 8.4 1 10.7 5.3 121 5 125 165 1.6 0 1.8 1.4 04/26/2006 06:00:00 8.3 1 11.1 5.7 8.4 1 11.1 6.1 8.2 1 11.1 5.7 128 7 120 165 1.7 0 1.8 1.4 04/26/2006 06:10:00 8.9 0.9 10.7 6.5 9 0.9 11.1 6.8 8.5 1 10.7 5.3 122 7 117 165 1.4 0.1 1.6 1.1 04/26/2006 06:20:00 9.6 0.5 10.7 8.4 9.8 0.5 11.1 8.4 9.5 0.5 11.1 8 122 3 124 165 1.3 0 1.6 0.9 04/26/2006 06:30:00 8.8 0.5 10.3 7.6 9 0.5 10.7 7.6 8.6 0.7 10.3 6.5 117 3 118 165 1.5 0 1.8 1.4 04/26/2006 06:40:00 9.4 0.9 12.6 6.1 9.7 0.9 12.2 6.5 9.1 1.1 12.2 5.7 114 5 114 165 1.6 0 1.8 1.6 04/26/2006 06:50:00 9.9 1.2 12.6 6.8 10.1 1.2 13 6.8 9.6 1.5 13 5.7 116 7 118 165 1.7 0 1.8 1.6 04/26/2006 07:00:00 9.4 0.8 11.8 6.5 9.6 0.9 12.2 6.5 9.5 0.9 12.2 6.8 125 7 123 165 1.7 0 1.8 1.6 04/26/2006 07:10:00 9.1 1.1 11.5 6.8 9.3 1.1 11.5 6.8 9.2 1.3 11.8 6.1 126 7 122 165 1.8 0 1.8 1.6 04/26/2006 07:20:00 8.6 1 11.5 4.9 8.7 1 11.5 5.3 8.6 0.9 11.1 6.1 123 6 125 165 1.8 0 1.8 1.6 04/26/2006 07:30:00 9.8 1 12.6 7.6 9.8 1 12.6 7.6 9.9 1.2 13 7.6 132 11 136 165 1.7 0 1.8 1.6 04/26/2006 07:40:00 11.8 1.3 14.9 8.4 11.7 1.3 14.9 8.4 11.7 1.5 15.3 8.4 138 6 145 165 1.5 0.1 1.8 1.4 04/26/2006 07:50:00 8.4 1.1 10.7 6.1 8.4 1.1 10.7 5.7 8.3 1.2 11.8 5.3 128 7 121 165 1.5 0 1.6 1.4 04/26/2006 08:00:00 8.6 0.9 11.1 6.1 8.6 0.8 11.1 6.5 8.5 0.9 11.1 5.7 124 5 127 165 1.6 0 1.8 1.4 04/26/2006 08:10:00 7.7 0.7 9.5 6.1 7.8 0.6 9.5 6.1 7.8 0.8 9.9 5.7 120 7 128 165 1.7 0 1.8 1.6 04/26/2006 08:20:00 8.4 1 10.3 5.3 8.5 1 10.3 5.3 8.4 1 10.3 5.3 122 7 124 165 1.7 0 1.8 1.6 04/26/2006 08:30:00 8.9 0.9 11.5 6.5 9 0.9 11.5 6.5 8.7 1 11.5 6.1 128 9 122 165 1.7 0 1.8 1.6 04/26/2006 08:40:00 9.3 1.1 11.8 6.5 9.4 1.1 11.5 6.1 9.3 1.2 12.2 5.7 139 7 144 165 1.7 0 1.8 1.6 04/26/2006 08:50:00 7.5 1 9.9 5.3 7.7 1 10.3 5.7 7.4 1 9.9 4.9 121 3 118 165 1.8 0 1.8 1.6 04/26/2006 09:00:00 6.9 0.5 8 5.3 7 0.5 8.4 5.7 6.8 0.6 8.4 5.3 118 5 121 165 1.8 0 1.8 1.6 04/26/2006 09:10:00 9.1 1 11.5 6.5 9.1 1 11.1 6.1 8.7 1.1 11.1 5.3 104 5 102 165 1.8 0 1.8 1.6 04/26/2006 09:20:00 7.6 0.9 9.9 4.9 7.6 0.9 9.9 5.3 7.6 1 9.9 5.3 141 15 145 165 1.8 0 1.8 1.6 04/26/2006 09:30:00 7 0.7 9.1 4.9 7.1 0.7 9.1 4.9 6.7 0.6 8.4 4.6 125 6 125 165 1.8 0 1.8 1.6 04/26/2006 09:40:00 8.1 1.2 12.2 5.7 8.3 1.2 11.8 5.7 7.6 1.1 11.5 5.7 119 6 121 165 1.9 0 2.1 1.8 04/26/2006 09:50:00 8.8 0.9 11.1 5.7 9 0.9 11.1 6.1 8.3 0.9 10.3 5.7 117 6 125 165 2 0 2.3 1.8 04/26/2006 10:00:00 10 1.2 13 6.8 10.2 1.2 13.3 6.8 9.5 1.2 13.3 7.2 115 7 117 165 2.1 0 2.3 1.8 04/26/2006 10:10:00 9.6 1 12.2 6.5 9.9 1 12.6 6.1 9.3 1 12.2 6.8 118 6 112 165 2.4 0 2.6 2.1 04/26/2006 10:20:00 9.9 1.2 13.3 6.8 10.2 1.2 13.7 6.8 9.5 1.3 13.3 4.9 117 7 129 165 2.1 0.1 2.6 1.8 04/26/2006 10:30:00 9.9 1.1 12.6 6.1 10.1 1.1 13.3 6.5 9.5 1.1 12.2 6.1 117 7 123 165 2.6 0.1 2.8 1.8 04/26/2006 10:40:00 10.5 1.2 13 7.6 10.8 1.2 13.7 7.6 9.9 1.2 13 6.5 112 6 111 165 2.9 0 3.3 2.8 04/26/2006 10:50:00 10.5 1 13.3 8 10.7 1 13.3 8 9.9 1 13 7.2 111 5 105 165 3 0 3.3 2.8 04/26/2006 11:00:00 10.8 1.7 14.5 5.3 11 1.7 14.5 5.3 10.2 1.7 13.7 5.7 115 7 114 165 3.1 0 3.3 2.8 04/26/2006 11:10:00 10.6 1.6 14.9 7.2 10.9 1.7 15.3 7.6 10.2 1.5 14.9 6.1 112 8 110 165 3.2 0 3.3 3 04/26/2006 11:20:00 11.3 1.3 13.7 8 11.5 1.4 14.1 8 10.7 1.5 14.1 7.2 111 6 110 165 3 0.1 3.5 2.8 04/26/2006 11:30:00 13.6 1.3 18.3 9.1 13.8 1.3 18.3 8.8 13.3 1.5 17.2 8 130 9 134 165 2.1 0.5 3 1.6 04/26/2006 11:40:00 10.4 1.5 14.1 7.6 10.6 1.5 14.5 8 10.2 1.7 14.9 6.5 128 7 132 165 1.7 0 1.8 1.6 04/26/2006 11:50:00 9.2 1.7 13 5.7 9.5 1.6 13 6.1 9.1 1.5 12.6 4.9 117 7 121 165 2.1 0.2 2.6 1.6 04/26/2006 12:00:00 8.6 0.9 11.1 6.1 8.9 0.9 11.1 5.7 8.1 1 10.7 6.1 115 7 115 165 2.5 0 2.6 2.3 04/26/2006 12:10:00 9.6 1.9 14.9 5.7 9.9 1.9 14.9 5.7 9 2 14.1 4.2 112 8 102 165 2.7 0 2.8 2.6 04/26/2006 12:20:00 10.5 1.2 13.3 6.8 10.7 1.2 13.7 7.6 9.7 1.2 13 6.8 107 6 105 165 2.8 0 2.8 2.8 04/26/2006 12:30:00 9.9 1.7 14.1 5.7 10.1 1.7 14.1 5.7 9 1.6 13.3 4.9 109 8 113 165 3 0 3.3 2.8 04/26/2006 12:40:00 13.3 1.5 16.1 7.6 13.5 1.5 16.1 7.2 12.4 1.6 15.6 8 107 6 107 165 2.3 0.3 2.8 1.8 04/26/2006 12:50:00 10.8 1.2 13 7.2 11.1 1.2 13.7 7.6 10.2 1.2 13.3 6.8 108 6 110 165 2.6 0.2 3 2.3 04/26/2006 13:00:00 9.7 1.1 12.6 6.8 9.9 1.2 13 6.8 9.2 1.1 11.5 6.1 105 8 99 165 3.2 0 3.5 2.8 04/26/2006 13:10:00 9.2 1.7 13 6.1 9.4 1.7 13.3 6.1 8.6 1.6 12.6 4.6 104 8 102 165 3.3 0 3.5 3.3 04/26/2006 13:20:00 9.7 1.5 14.1 5.7 9.9 1.5 14.1 6.1 9.1 1.5 13.7 5.3 107 9 108 165 3.2 0 3.3 3 04/26/2006 13:30:00 10.6 1.3 13.7 7.2 10.9 1.3 14.1 7.6 10.2 1.3 13.3 6.8 102 7 102 165 3.1 0.1 3.3 3 04/26/2006 13:40:00 10.2 1.2 13.3 6.8 10.4 1.2 14.1 7.2 9.6 1.3 13 6.5 101 6 93 165 3 0 3.3 3 04/26/2006 13:50:00 9.7 1.3 13 5.7 10 1.4 13.3 6.1 9.3 1.3 12.6 6.1 98 8 85 165 3.1 0 3.3 3 04/26/2006 14:00:00 9.7 1.4 12.2 5.7 9.9 1.5 13 5.7 9.2 1.4 12.6 5.7 98 10 90 165 3 0.1 3.3 2.8 04/26/2006 14:10:00 10.7 1.7 14.5 6.8 11 1.7 14.5 7.2 10.5 1.7 14.5 6.5 118 9 117 165 2.2 0.4 3 1.8 04/26/2006 14:20:00 8.7 1 11.5 6.1 8.9 1 11.8 6.1 8 1.1 11.5 5.3 111 7 111 165 2.2 0.2 2.6 1.8 04/26/2006 14:30:00 8.6 1.6 12.2 4.6 8.8 1.5 12.2 4.9 8.1 1.5 11.8 4.2 101 9 114 165 2.7 0 2.8 2.3 04/26/2006 14:40:00 9.7 1.6 13.7 6.1 9.9 1.6 13.7 6.5 9 1.5 13 4.9 98 6 90 165 2.9 0.1 3.3 2.8 04/26/2006 14:50:00 11 1.2 13.7 7.6 11.3 1.2 14.5 7.2 10.3 1.3 13.3 6.8 93 8 97 165 3.2 0 3.3 3 04/26/2006 15:00:00 11.7 1.5 14.9 7.2 11.9 1.6 15.3 8 11 1.7 14.5 5.7 97 7 99 165 3 0 3.3 2.8 04/26/2006 15:10:00 11 1.9 15.6 7.2 11.2 1.9 16.1 6.8 10.3 1.9 14.9 6.5 98 8 96 165 3 0 3.3 2.8 04/26/2006 15:20:00 12.5 2.5 17.2 6.5 12.7 2.5 17.9 6.5 12 2.6 17.6 6.8 116 9 114 165 2.2 0.6 3 1.6 04/26/2006 15:30:00 11.6 1.3 14.5 7.6 11.7 1.3 14.5 7.6 10.6 1.3 13.7 6.8 107 9 93 165 1.7 0 1.8 1.6 04/26/2006 15:40:00 10.8 1.1 13.7 7.2 11.1 1.2 14.1 7.6 10.2 1.2 13 6.8 88 6 92 165 1.8 0 2.1 1.6 04/26/2006 15:50:00 9.8 1.3 13 6.5 10 1.3 13 6.5 9.3 1.3 12.2 6.1 90 9 89 165 2.2 0 2.3 1.8 04/26/2006 16:00:00 11.5 1.6 16.4 7.6 11.7 1.7 16.8 8 10.7 1.6 15.6 6.5 106 13 112 165 2.1 0.3 2.6 1.6 04/26/2006 16:10:00 10.5 1.5 13 7.2 10.7 1.5 13.7 7.2 9.6 1.5 13 6.1 95 8 97 165 1.7 0 1.8 1.6 04/26/2006 16:20:00 12 1.4 14.9 7.2 12.3 1.5 15.6 6.8 11.2 1.5 14.1 7.2 90 6 85 165 1.7 0 1.8 1.6 04/26/2006 16:30:00 10.6 1.5 13.3 6.8 10.8 1.5 13.7 6.8 10.1 1.4 13.7 6.5 88 7 91 165 1.8 0 1.8 1.8 04/26/2006 16:40:00 10.1 1.3 13.3 7.2 10.6 1.4 13.7 7.2 9.9 1.3 13.3 7.2 93 7 90 165 1.9 0 1.8 1.8 04/26/2006 16:50:00 10 1.2 12.6 5.3 10.2 1.2 13 6.1 9.4 1.2 13 6.5 99 7 91 165 1.9 0 2.1 1.8 04/26/2006 17:00:00 9 1.2 11.8 6.1 9.3 1.3 11.8 6.5 8.5 1.3 11.8 4.9 97 8 99 165 2 0 2.3 1.8 04/26/2006 17:10:00 9.1 1.3 11.8 4.9 9.3 1.4 11.8 5.3 8.7 1.3 11.5 5.3 88 8 96 165 2.1 0 2.3 1.8 04/26/2006 17:20:00 10.9 1 13.7 8 11.2 1 13.7 8 10.3 1.1 13 7.6 87 5 92 165 1.8 0 2.3 1.6 04/26/2006 17:30:00 10.4 1.3 13 7.2 10.6 1.3 13.3 7.2 9.9 1.4 13.3 6.5 91 6 90 165 1.8 0 1.8 1.6 04/26/2006 17:40:00 9.4 1.3 12.6 6.1 9.6 1.3 13 6.5 9.2 1.3 12.2 6.5 84 8 91 165 1.8 0 1.8 1.6 04/26/2006 17:50:00 9.8 1.1 11.5 6.8 10 1.1 11.8 6.8 9.4 1.1 11.5 6.1 84 6 84 165 1.8 0 1.8 1.6 04/26/2006 18:00:00 9.9 1 11.8 6.5 10.2 1 12.2 6.8 9.6 1.1 11.8 6.5 87 5 84 165 1.9 0 2.1 1.8 04/26/2006 18:10:00 9.2 1.1 11.1 4.9 9.4 1.1 11.5 4.9 8.7 1 10.7 5.7 88 6 88 165 2.1 0 2.3 1.8 04/26/2006 18:20:00 8.7 1.1 11.1 5.7 9 1.1 11.5 5.7 8.4 1.2 11.5 5.7 85 9 86 165 2.2 0 2.3 2.1 04/26/2006 18:30:00 8.1 1 11.1 5.3 8.4 1.1 11.1 5.3 8.1 1 10.3 5.7 79 7 80 165 2 0.1 2.3 1.8 04/26/2006 18:40:00 9.2 1 11.5 6.5 9.5 1 11.8 6.5 9 1 11.5 5.7 81 7 87 165 1.8 0 1.8 1.6 04/26/2006 18:50:00 8.6 1 11.1 5.7 8.9 1.1 11.1 5.7 8.5 1.1 11.5 6.1 79 8 84 165 1.8 0 1.8 1.6 04/26/2006 19:00:00 8.6 1.1 11.1 5.7 8.8 1.1 11.5 6.1 8.1 1.2 10.7 5.3 87 8 83 165 1.8 0 1.8 1.6 04/26/2006 19:10:00 8.7 1 10.7 6.1 8.9 1 10.7 6.1 8.4 1 11.1 5.7 95 5 97 165 1.8 0 1.8 1.6 04/26/2006 19:20:00 8.4 0.9 10.3 6.1 8.5 0.9 10.7 5.7 7.7 1 9.9 5.7 95 7 91 165 1.9 0 2.1 1.8 04/26/2006 19:30:00 8.2 0.9 10.3 5.3 8.5 1 10.7 6.1 7.9 0.9 10.7 6.1 85 6 88 165 1.8 0 2.1 1.6 04/26/2006 19:40:00 8.5 1 11.1 6.1 8.7 1 11.5 6.5 8.2 1 10.7 5.3 87 8 90 165 1.8 0 1.8 1.6 04/26/2006 19:50:00 9 1 11.1 6.1 9.2 0.9 11.1 6.5 8.5 0.9 10.7 6.1 82 2 82 165 1.7 0 1.8 1.6 04/26/2006 20:00:00 6.7 1.2 9.5 3.8 7.1 1.1 9.9 4.6 6.5 1.2 9.9 3.8 82 0 82 165 1.6 0 1.8 1.4 04/26/2006 20:10:00 6.6 0.9 8.4 3.8 7.1 0.9 9.1 4.2 6.7 0.8 8.4 4.6 82 0 82 165 1.4 0 1.6 1.4 04/26/2006 20:20:00 6.4 1 8.8 3.8 6.9 0.9 9.1 4.6 6.4 0.9 8.8 4.2 82 0 82 165 1.4 0 1.6 1.4 04/26/2006 20:30:00 6.5 0.7 8 4.6 7 0.8 8.4 4.9 6.5 0.7 8 4.6 82 0 83 165 1.4 0 1.4 1.4 04/26/2006 20:40:00 5.5 0.7 7.2 3.8 5.9 0.7 7.6 4.2 5.7 0.6 7.2 4.2 82 0 82 165 1.3 0 1.4 1.1 04/26/2006 20:50:00 5 0.5 6.8 3.8 5.4 0.6 7.2 3.8 5.2 0.5 6.8 4.2 82 0 82 165 1.2 0 1.4 0.9 04/26/2006 21:00:00 5.1 0.7 6.8 3.4 5.6 0.7 7.6 3.8 5.4 0.6 6.8 3.4 82 0 82 165 1.1 0 1.4 0.9 04/26/2006 21:10:00 5.4 0.5 7.2 4.2 6.2 0.5 7.6 4.6 5.6 0.5 6.8 4.2 82 0 82 165 1.2 0 1.4 0.9 04/26/2006 21:20:00 5.9 0.5 7.2 4.6 6.5 0.4 7.6 4.9 6.1 0.5 7.6 4.9 82 0 82 165 1.2 0 1.4 0.9 04/26/2006 21:30:00 5.6 0.6 6.8 4.2 6.2 0.6 7.6 4.6 5.6 0.7 7.2 4.2 82 0 82 165 1.3 0 1.4 1.1 04/26/2006 21:40:00 4.9 0.4 5.7 3.8 5.6 0.4 6.5 3.8 5 0.5 6.1 3.8 82 0 82 165 1.4 0 1.4 1.4 04/26/2006 21:50:00 5.4 0.4 6.8 3.8 6.1 0.5 7.6 4.2 5.5 0.6 7.2 3.8 82 0 83 165 1.4 0 1.6 1.4 04/26/2006 22:00:00 5.1 0.5 6.1 3.8 5.5 0.5 6.5 4.2 5.4 0.7 6.5 3.4 82 0 83 165 1.3 0 1.4 1.4 04/26/2006 22:10:00 3.5 0.4 4.6 2.3 3.9 0.4 4.9 2.6 3.8 0.5 4.9 2.3 83 0 82 165 1.2 0 1.4 1.1 04/26/2006 22:20:00 2.8 0.5 3.8 1.1 3.1 0.5 4.2 1.5 3.1 0.4 4.2 1.9 82 0 82 165 1.2 0 1.4 1.1 04/26/2006 22:30:00 0.9 1 3.8 0.4 3.1 0.8 4.9 1.1 2.8 0.6 4.9 1.5 82 0 82 165 1 0.1 1.4 0.9 04/26/2006 22:40:00 0.4 0 0.4 0.4 3.7 0.6 4.9 2.3 3.3 0.5 4.9 1.9 82 0 165 165 0.9 0 1.1 0.9 04/26/2006 22:50:00 0.4 0 0.4 0.4 3.6 1.1 5.7 0.4 3.4 0.9 5.3 1.5 82 0 165 165 1 0 1.4 0.9 04/26/2006 23:00:00 0.4 0 0.4 0.4 1.8 2.2 6.1 0.4 3.8 1.1 6.1 1.1 82 0 165 165 1.1 0.1 1.4 0.9 04/26/2006 23:10:00 0.4 0 0.4 0.4 4.5 0.5 5.7 3 4.3 0.6 5.7 2.6 82 0 165 165 1.5 0 1.6 1.1 04/26/2006 23:20:00 0.4 0 0.4 0.4 4.6 0.6 5.7 2.6 4.3 0.6 5.7 2.6 82 0 165 165 1.5 0 1.6 1.4 04/26/2006 23:30:00 0.4 0 0.4 0.4 4.4 0.5 5.7 3.4 4.1 0.6 5.3 2.6 82 0 165 165 1.4 0 1.6 1.4 04/26/2006 23:40:00 0.4 0 0.4 0.4 3.8 0.6 5.3 2.3 3.6 0.6 4.9 2.3 82 0 165 165 1.4 0 1.6 1.4 04/26/2006 23:50:00 0.4 0 0.4 0.4 3.3 0.3 4.2 2.6 3.3 0.4 3.8 2.3 82 0 165 165 1.3 0 1.4 1.4 04/27/2006 00:00:00 0.4 0 0.4 0.4 3.6 0.4 4.6 2.3 3.6 0.4 4.6 2.3 82 0 165 165 1.2 0 1.4 1.1 04/27/2006 00:10:00 0.4 0 0.4 0.4 4.1 0.6 5.3 2.3 3.8 0.5 4.9 2.3 82 0 165 165 1.2 0 1.4 1.1 04/27/2006 00:20:00 0.4 0 0.4 0.4 4.6 0.5 5.7 3 4.4 0.5 5.7 3 82 0 165 165 1.4 0 1.6 1.1 04/27/2006 00:30:00 0.4 0 0.4 0.4 4.6 0.3 5.3 3.8 4.2 0.4 4.9 3 82 0 165 165 1.4 0 1.6 1.4 04/27/2006 00:40:00 0.4 0 0.4 0.4 3.9 0.6 5.3 2.3 3.6 0.6 4.9 1.9 82 0 165 165 1.2 0 1.4 1.1 04/27/2006 00:50:00 0.4 0 0.4 0.4 3.3 0.8 5.3 1.5 3.1 0.7 4.9 1.9 82 0 165 165 1.3 0 1.4 1.1 04/27/2006 01:00:00 0.4 0 0.4 0.4 3.1 0.8 5.3 1.5 3 0.6 4.9 1.5 82 0 165 165 1.3 0 1.4 1.4 04/27/2006 01:10:00 0.4 0 0.4 0.4 3.4 0.7 5.7 1.5 3.2 0.7 4.9 1.9 82 0 165 165 1.3 0 1.4 0.9 04/27/2006 01:20:00 0.4 0 0.4 0.4 3.9 0.8 6.1 1.9 3.7 0.8 5.7 1.9 82 0 165 165 1.4 0 1.6 1.4 04/27/2006 01:30:00 0.4 0 0.4 0.4 4.1 0.8 5.7 1.9 3.8 0.7 5.3 1.9 82 0 165 165 1.5 0 1.6 1.4 04/27/2006 01:40:00 0.4 0 0.4 0.4 4.3 0.8 6.1 2.3 4 0.8 6.1 2.3 82 0 165 165 1.5 0 1.6 1.4 04/27/2006 01:50:00 0.4 0 0.4 0.4 4.1 0.8 6.1 1.9 3.9 0.8 6.1 1.5 82 0 165 165 1.4 0 1.6 1.4 04/27/2006 02:00:00 0.4 0 0.4 0.4 3.9 0.9 6.1 1.9 3.7 0.8 5.3 1.5 82 0 165 165 1.4 0 1.6 1.4 04/27/2006 02:10:00 0.4 0 0.4 0.4 4.7 0.8 6.8 3 4.4 0.7 6.1 2.6 82 0 165 165 1.2 0 1.4 1.1 04/27/2006 02:20:00 0.4 0 0.4 0.4 6.7 0.8 8 4.2 6.1 0.7 7.6 3.4 82 0 165 165 1.1 0 1.4 0.9 04/27/2006 02:30:00 0.4 0 0.4 0.4 6.1 0.4 6.8 4.9 5.5 0.5 6.5 4.2 82 0 165 165 1.1 0 1.4 0.9 04/27/2006 02:40:00 0.4 0 0.4 0.4 5.2 0.9 6.8 3 4.7 0.9 6.5 2.3 82 0 165 165 0.9 0 1.1 0.9 04/27/2006 02:50:00 0.4 0 0.4 0.4 3.1 0.6 4.9 1.9 2.9 0.6 4.2 1.1 82 0 165 165 1 0 1.4 0.9 04/27/2006 03:00:00 0.4 0 0.4 0.4 0.7 0.9 4.6 0.4 3.8 1 6.1 1.5 82 0 165 165 1.1 0.1 1.4 0.9 04/27/2006 03:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 3.6 0.9 5.7 1.5 82 0 165 165 1.4 0 1.6 1.4 04/27/2006 03:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 3.6 0.8 5.7 1.9 82 0 165 165 1.4 0 1.6 1.4 04/27/2006 03:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 3.3 0.7 5.3 1.9 82 0 165 165 1.5 0 1.6 1.4 04/27/2006 03:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 1.6 1.1 3.8 0.4 82 0 165 165 1.5 0 1.6 1.4 04/27/2006 03:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 82 0 165 165 1.5 0 1.6 1.4 04/27/2006 04:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 82 0 165 165 1.5 0 1.6 1.4 04/27/2006 04:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 82 0 165 165 1.6 0 1.6 1.4 04/27/2006 04:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 82 0 165 165 1.6 0 1.6 1.6 04/27/2006 04:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 82 0 165 165 1.5 0 1.6 1.4 04/27/2006 04:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 82 0 165 165 1.6 0 1.6 1.4 04/27/2006 04:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 82 0 165 165 1.6 0 1.8 1.4 04/27/2006 05:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 82 0 165 165 1.7 0 1.8 1.6 04/27/2006 05:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 82 0 165 165 1.7 0 1.8 1.6 04/27/2006 05:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 82 0 165 165 1.7 0 1.8 1.6 04/27/2006 05:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 82 0 165 165 1.7 0 1.8 1.4 04/27/2006 05:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 82 0 165 165 1.7 0 1.8 1.6 04/27/2006 05:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 82 0 165 165 1.7 0 1.8 1.6 04/27/2006 06:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 82 0 165 165 1.7 0 1.8 1.6 04/27/2006 06:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 82 0 165 165 1.7 0 1.8 1.6 04/27/2006 06:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 82 0 165 165 1.8 0 1.8 1.6 04/27/2006 06:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 82 0 165 165 1.8 0 1.8 1.6 04/27/2006 06:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 81 0 165 165 1.7 0 1.8 1.6 04/27/2006 06:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 81 0 165 165 1.7 0 1.8 1.6 04/27/2006 07:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 81 0 165 165 1.8 0 1.8 1.6 04/27/2006 07:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 80 0 165 165 1.8 0 1.8 1.6 04/27/2006 07:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 67 23 165 165 1.8 0 1.8 1.6 04/27/2006 07:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 17 9 165 165 1.8 0 1.8 1.6 04/27/2006 07:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 7.1 3.2 10.7 0.4 15 7 165 165 1.8 0 1.8 1.6 04/27/2006 07:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 6.8 1 9.5 4.2 31 11 165 165 1.8 0 1.8 1.6 04/27/2006 08:00:00 7.3 2.8 9.9 0.4 8.9 3.6 14.1 0.4 9.9 1.6 14.5 5.3 41 8 26 165 1.8 0 1.8 1.6 04/27/2006 08:10:00 10.3 1.9 13.7 5.7 10.6 1.6 13.7 6.5 10.6 1.7 14.1 5.7 34 7 37 165 1.8 0 1.8 1.6 04/27/2006 08:20:00 9.3 1.3 12.2 5.7 9.2 1.3 11.8 5.7 9.2 1.4 12.6 5.3 35 7 31 165 1.8 0 1.8 1.6 04/27/2006 08:30:00 9.8 1.6 13.7 4.9 9.7 1.7 13.7 4.9 9.5 1.6 13.3 5.3 31 7 28 165 1.8 0 1.8 1.8 04/27/2006 08:40:00 8.7 1.6 13.3 5.3 8.6 1.7 13.7 4.2 8.2 1.7 13.3 4.6 35 9 45 165 1.8 0 1.8 1.6 04/27/2006 08:50:00 12 1.6 15.6 7.2 11.9 1.7 16.1 7.2 11.8 1.7 16.4 8 38 8 43 165 2 0 2.3 1.6 04/27/2006 09:00:00 11 1.6 15.3 7.2 11 1.6 14.9 6.8 10.6 1.7 14.9 6.5 43 9 35 165 1.9 0 2.1 1.8 04/27/2006 09:10:00 10.5 1.5 14.1 6.8 10.5 1.5 14.1 7.2 10.4 1.5 14.5 7.2 38 8 41 165 2 0 2.1 1.8 04/27/2006 09:20:00 11.8 1.6 15.6 7.6 11.8 1.7 16.1 7.6 11.5 1.8 16.4 6.8 37 8 40 165 2.2 0 2.3 1.8 04/27/2006 09:30:00 10.2 1.9 14.1 6.1 10.1 2 14.5 5.7 9.9 1.7 14.5 6.1 34 9 22 165 2.3 0 2.6 2.1 04/27/2006 09:40:00 12 2.5 16.4 5.7 12 2.6 16.4 5.7 11.9 2.7 17.2 6.1 38 8 36 165 2.3 0 2.6 2.1 04/27/2006 09:50:00 11.5 1.7 15.3 8 11.4 1.7 15.3 7.2 11.3 1.7 15.6 7.6 34 9 36 165 2 0 2.3 1.8 04/27/2006 10:00:00 11.8 1.7 17.6 7.6 11.8 1.8 17.6 8 11.6 1.6 16.4 7.2 40 9 51 165 2.4 0 2.6 2.3 04/27/2006 10:10:00 13.5 1.7 18.7 7.6 13.6 1.8 18.7 7.2 13.2 1.8 17.9 8 42 8 45 165 2.1 0.2 2.6 1.8 04/27/2006 10:20:00 11.4 1.5 14.9 7.6 11.3 1.5 15.3 7.6 11 1.4 14.5 7.6 37 8 46 165 2 0 2.3 1.8 04/27/2006 10:30:00 13.1 2.1 18.3 8.4 13 2.1 18.7 8 12.5 2.2 18.3 7.6 37 10 39 165 2.6 0 2.8 2.1 04/27/2006 10:40:00 14.4 2.2 19.5 8 14.4 2.3 20.2 8 13.9 2.2 20.2 7.2 38 9 45 165 2.6 0.1 2.8 2.3 04/27/2006 10:50:00 14.3 2.2 19.5 9.9 14.3 2.2 19.9 9.9 13.9 2.3 20.2 8.4 38 8 45 165 2.6 0 2.8 2.3 04/27/2006 11:00:00 14.4 2 19.9 9.9 14.3 2.1 19.9 9.9 13.8 2.1 19.9 8.8 33 8 35 165 2.7 0 2.8 2.6 04/27/2006 11:10:00 12.8 2.1 19.9 8 12.6 2.2 19.9 8 12.2 1.9 19.1 8.4 31 9 43 165 2.7 0 2.8 2.6 04/27/2006 11:20:00 14.9 2.1 20.6 9.5 14.8 2.3 20.2 9.1 14.5 2.3 19.5 8.8 33 9 43 165 2.7 0 2.8 2.6 04/27/2006 11:30:00 14.9 2.3 20.2 9.9 14.8 2.4 20.6 10.3 14.3 2.2 20.6 9.5 33 9 43 165 2.7 0 2.8 2.6 04/27/2006 11:40:00 13.3 2.1 19.1 8 13.1 2.2 19.1 8 12.8 2.2 19.5 8.4 30 10 37 165 2.7 0 2.8 2.6 04/27/2006 11:50:00 14.9 2.7 20.6 8.8 14.7 2.8 21.4 8.4 14.3 2.6 21 8.8 31 9 42 165 2.7 0 2.8 2.6 04/27/2006 12:00:00 14.8 2 19.5 8.8 14.6 2.1 19.5 8.8 14.3 2.2 19.5 9.9 32 8 36 165 2.6 0 2.8 2.6 04/27/2006 12:10:00 16.3 1.9 21.4 11.5 16.3 1.9 21.4 11.1 16 2.1 21.4 9.9 36 8 41 165 2.3 0 2.6 2.3 04/27/2006 12:20:00 15.5 2.5 21.4 9.1 15.3 2.6 21.4 8.4 15 2.6 19.9 9.1 31 8 29 165 2.3 0.1 2.8 2.1 04/27/2006 12:30:00 15.6 2.3 20.6 9.5 15.1 2.4 20.6 9.5 15 2.3 20.2 9.9 25 9 30 165 2.6 0 2.8 2.6 04/27/2006 12:40:00 15.7 1.7 19.9 10.7 15.1 1.8 19.9 9.1 15 1.7 18.7 10.7 21 8 23 165 2.6 0 2.8 2.6 04/27/2006 12:50:00 16 2 20.2 9.9 15.3 2.3 20.6 7.6 15.3 1.8 19.9 9.5 20 8 25 165 2.6 0 2.8 2.6 04/27/2006 13:00:00 14.2 2.3 21.8 9.1 13.5 2.6 21.4 8 13.5 2.2 21 8.8 22 9 32 165 2.5 0 2.8 2.6 04/27/2006 13:10:00 15.3 2 21.4 10.7 14.1 2.5 21.4 8.8 14.6 2.2 21.8 9.1 17 9 23 165 2.6 0 2.8 2.6 04/27/2006 13:20:00 15.7 1.7 20.2 11.5 13.7 2.5 19.1 8.4 15.1 1.9 19.5 10.3 13 9 18 165 2.5 0 2.8 2.3 04/27/2006 13:30:00 16.7 1.7 21.8 12.6 15.3 2.4 21.8 9.1 16.1 2 22.6 11.8 15 7 19 165 2.4 0 2.6 2.3 04/27/2006 13:40:00 17.4 2.3 24 11.5 15.9 2.9 23.3 9.5 16.9 2 22.6 11.8 15 8 18 165 2.4 0 2.6 2.3 04/27/2006 13:50:00 17.6 2.2 22.6 12.2 15.6 2.9 22.1 8 17.4 2.3 23.3 11.1 13 8 14 165 2.3 0 2.3 2.1 04/27/2006 14:00:00 16.8 1.9 21.8 12.2 14.4 2.8 21 8.4 16.4 2 22.1 10.7 12 8 12 165 2 0 2.3 1.8 04/27/2006 14:10:00 17.1 2.1 22.6 10.7 15.2 2.7 22.1 8.8 16.6 2.1 22.6 11.1 15 8 14 165 2 0 2.1 1.8 04/27/2006 14:20:00 18.1 2.2 22.9 12.6 14.8 3.2 21.4 8 18.1 2.2 22.6 13.3 11 8 12 165 1.9 0 2.1 1.8 04/27/2006 14:30:00 16.1 2.6 22.1 9.9 14.2 3.5 22.6 6.8 16.2 2.6 22.9 9.5 13 8 25 165 1.9 0 1.8 1.8 04/27/2006 14:40:00 15.7 2.3 21.4 9.9 12.1 2.9 19.9 7.2 15.4 2.4 21.4 8 7 8 14 165 1.8 0 1.8 1.8 04/27/2006 14:50:00 16.3 2.3 23.3 9.9 12.1 2.5 21.8 7.2 15.9 2.5 22.6 9.5 7 8 4 165 1.8 0 1.8 1.8 04/27/2006 15:00:00 15.2 2 22.6 10.7 11 2.7 21.4 6.8 14.9 1.9 20.6 11.1 3 10 38 165 1.8 0 1.8 1.8 04/27/2006 15:10:00 14.6 2.4 21.8 9.5 10.8 2.8 19.9 5.7 14.3 2.4 21.8 9.9 5 8 359 165 1.8 0 1.8 1.6 04/27/2006 15:20:00 14.3 2.1 20.2 9.5 10.1 2.4 17.6 6.1 14 2.1 21 8.4 2 7 7 165 1.8 0 1.8 1.6 04/27/2006 15:30:00 14.2 2.5 23.3 9.9 10.3 2.7 20.2 5.7 14 2.5 23.3 9.1 2 2 3 165 1.8 0 1.8 1.6 04/27/2006 15:40:00 15.2 2.5 21 8.8 11.7 2.9 21 6.8 14.8 2.5 20.2 8.4 358 7 6 165 1.8 0 1.8 1.6 04/27/2006 15:50:00 14.8 2 20.6 9.5 10.5 1.9 16.8 6.5 14.2 2.2 19.1 8.8 0 7 358 165 1.8 0 1.8 1.6 04/27/2006 16:00:00 13.6 2 20.2 8 10.4 2.4 19.1 6.1 13 1.8 18.7 8.8 356 8 15 165 1.8 0 1.8 1.6 04/27/2006 16:10:00 16 2.6 23.3 9.1 11.8 2.6 19.5 6.5 15.4 2.6 22.1 7.2 357 7 9 165 1.8 0 1.8 1.6 04/27/2006 16:20:00 15.9 1.8 21.8 11.8 11.8 2.6 18.3 6.8 15.2 1.9 20.2 10.7 357 8 4 165 1.7 0 1.8 1.6 04/27/2006 16:30:00 14 1.7 19.1 9.5 10.2 2 16.8 6.5 13.3 2 17.9 8.8 358 6 353 165 1.7 0 1.8 1.6 04/27/2006 16:40:00 15.6 2.1 20.6 9.5 11.3 1.9 17.6 6.5 14.9 2.3 19.5 9.1 2 7 358 165 1.7 0 1.8 1.6 04/27/2006 16:50:00 12.2 2.2 20.6 8 10.2 2.4 19.1 6.1 11.7 2.1 19.9 7.6 10 8 18 165 1.5 0.1 1.8 1.4 04/27/2006 17:00:00 10.7 1.1 14.1 8 10.2 1.5 14.5 5.3 10.2 1.2 13.7 7.6 20 8 28 165 1.3 0 1.4 1.1 04/27/2006 17:10:00 9.9 1.1 12.6 6.5 9.6 1.2 12.6 6.1 9.3 1.1 11.8 5.7 28 6 32 165 1.2 0 1.4 0.9 04/27/2006 17:20:00 8.9 1.1 13 6.1 8.7 1.1 13 5.7 8.4 1.1 12.2 5.3 32 0 32 165 1.1 0 1.4 0.9 04/27/2006 17:30:00 6.9 1.3 11.5 4.6 6.6 1.3 11.5 3.8 6.3 1.2 9.5 3.8 32 0 32 165 0.9 0 1.1 0.9 04/27/2006 17:40:00 1.5 1.9 6.5 0.4 1.1 1.6 6.1 0.4 1.4 1.7 6.8 0.4 32 0 32 165 0.5 0.2 0.9 0.2 04/27/2006 17:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 32 0 165 165 0.2 0 0.2 0.2 04/27/2006 18:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 32 0 165 165 0.2 0 0.4 0.2 04/27/2006 18:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 32 0 165 165 0.2 0 0.4 0.2 04/27/2006 18:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 32 0 165 165 0.2 0 0.4 0.2 04/27/2006 18:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 32 0 165 165 0.1 0 0.2 -0.1 04/27/2006 18:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 32 0 165 165 -0.3 0 -0.1 -0.3 04/27/2006 18:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 32 0 165 165 -0.2 0 0.2 -0.5 04/27/2006 19:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 32 0 165 165 0 0 0.2 -0.1 04/27/2006 19:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 32 0 165 165 0 0 0.2 -0.3 04/27/2006 19:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 32 0 165 165 -0.1 0 0.2 -0.3 04/27/2006 19:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 32 0 165 165 -0.2 0 -0.1 -0.3 04/27/2006 19:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 32 0 165 165 -0.3 0 -0.1 -0.3 04/27/2006 19:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 32 0 165 165 -0.3 0 -0.1 -0.5 04/27/2006 20:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 32 0 165 165 -0.6 0.1 -0.3 -0.8 04/27/2006 20:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 32 0 165 165 -0.8 0 -0.8 -0.8 04/27/2006 20:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 32 0 165 165 -0.8 0 -0.5 -0.8 04/27/2006 20:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 32 0 165 165 -0.8 0 -0.5 -0.8 04/27/2006 20:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 32 0 165 165 -0.8 0 -0.5 -0.8 04/27/2006 20:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 32 0 165 165 -0.7 0 -0.5 -0.8 04/27/2006 21:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 32 0 165 165 -0.7 0 -0.5 -0.8 04/27/2006 21:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 32 0 165 165 -0.8 0 -0.5 -0.8 04/27/2006 21:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 32 0 165 165 -0.8 0 -0.5 -0.8 04/27/2006 21:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 32 0 165 165 -0.8 0 -0.5 -0.8 04/27/2006 21:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 32 0 165 165 -0.7 0 -0.5 -0.8 04/27/2006 21:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 32 0 165 165 -0.7 0 -0.5 -0.8 04/27/2006 22:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 32 0 165 165 -0.6 0 -0.5 -0.8 04/27/2006 22:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 32 0 165 165 -0.6 0 -0.5 -0.8 04/27/2006 22:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 32 0 165 165 -0.6 0 -0.5 -0.8 04/27/2006 22:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 32 0 165 165 -0.6 0 -0.5 -0.8 04/27/2006 22:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 32 0 165 165 -0.6 0 -0.5 -0.8 04/27/2006 22:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 32 0 165 165 -0.6 0 -0.5 -0.8 04/27/2006 23:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 32 0 165 165 -0.6 0 -0.5 -0.8 04/27/2006 23:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 32 0 165 165 -0.5 0 -0.5 -0.8 04/27/2006 23:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 32 0 165 165 -0.5 0 -0.5 -0.5 04/27/2006 23:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 32 0 165 165 -0.5 0 -0.3 -0.5 04/27/2006 23:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 32 0 165 165 -0.5 0 -0.3 -0.5 04/27/2006 23:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 32 0 165 165 -0.5 0 -0.3 -0.5 04/28/2006 00:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 32 0 165 165 -0.4 0 -0.3 -0.8 04/28/2006 00:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 32 0 165 165 -0.3 0 -0.3 -0.5 04/28/2006 00:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 32 0 165 165 -0.4 0 -0.3 -0.5 04/28/2006 00:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 32 0 165 165 -0.5 0 -0.5 -0.5 04/28/2006 00:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 32 0 165 165 -0.5 0 -0.3 -0.5 04/28/2006 00:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 32 0 165 165 -0.4 0 -0.3 -0.5 04/28/2006 01:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 32 0 165 165 -0.3 0 -0.3 -0.5 04/28/2006 01:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 32 0 165 165 -0.3 0 -0.3 -0.5 04/28/2006 01:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 32 0 165 165 -0.3 0 -0.3 -0.5 04/28/2006 01:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 32 0 165 165 -0.3 0 -0.3 -0.5 04/28/2006 01:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 32 0 165 165 -0.3 0 -0.3 -0.5 04/28/2006 01:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 32 0 165 165 -0.3 0 -0.1 -0.5 04/28/2006 02:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 32 0 165 165 -0.3 0 -0.1 -0.5 04/28/2006 02:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 32 0 165 165 -0.2 0 -0.1 -0.3 04/28/2006 02:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 32 0 165 165 -0.1 0 0.2 -0.1 04/28/2006 02:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 32 0 165 165 -0.1 0 0.2 -0.3 04/28/2006 02:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 32 0 165 165 -0.2 0 -0.1 -0.3 04/28/2006 02:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 32 0 165 165 -0.2 0 -0.1 -0.3 04/28/2006 03:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 32 0 165 165 -0.2 0 -0.1 -0.3 04/28/2006 03:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 32 0 165 165 -0.2 0 -0.1 -0.3 04/28/2006 03:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 32 0 165 165 -0.1 0 0.2 -0.3 04/28/2006 03:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 32 0 165 165 -0.1 0 0.2 -0.1 04/28/2006 03:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 32 0 165 165 -0.2 0 -0.1 -0.3 04/28/2006 03:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 32 0 165 165 -0.2 0 -0.1 -0.3 04/28/2006 04:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 32 0 165 165 -0.1 0 -0.1 -0.3 04/28/2006 04:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 32 0 165 165 -0.1 0 0.2 -0.1 04/28/2006 04:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 32 0 165 165 -0.1 0 0.2 -0.1 04/28/2006 04:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 32 0 165 165 0 0 0.2 -0.1 04/28/2006 04:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 32 0 165 165 0 0 0.2 -0.1 04/28/2006 04:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 32 0 165 165 -0.1 0 0.2 -0.3 04/28/2006 05:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 32 0 165 165 -0.2 0 -0.1 -0.3 04/28/2006 05:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 32 0 165 165 -0.2 0 -0.1 -0.3 04/28/2006 05:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 32 0 165 165 -0.1 0 0.2 -0.3 04/28/2006 05:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 32 0 165 165 0 0 0.2 -0.1 04/28/2006 05:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 32 0 165 165 0.1 0 0.2 -0.1 04/28/2006 05:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 32 0 165 165 0.1 0 0.2 -0.1 04/28/2006 06:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 32 0 165 165 0 0 0.2 -0.1 04/28/2006 06:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 32 0 165 165 0.1 0 0.2 -0.1 04/28/2006 06:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 32 0 165 165 0.1 0 0.2 -0.1 04/28/2006 06:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 32 0 165 165 0.2 0 0.2 -0.1 04/28/2006 06:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 32 0 165 165 0.1 0 0.2 -0.1 04/28/2006 06:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 32 0 165 165 0 0 0.2 -0.1 04/28/2006 07:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 32 0 165 165 -0.1 0 0.2 -0.3 04/28/2006 07:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 32 0 165 165 -0.1 0 0.2 -0.3 04/28/2006 07:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 32 0 165 165 0 0 0.2 -0.1 04/28/2006 07:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 32 0 165 165 0.1 0 0.2 -0.1 04/28/2006 07:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 32 0 165 165 0.1 0 0.2 -0.1 04/28/2006 07:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 32 0 165 165 0.2 0 0.2 0.2 04/28/2006 08:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 32 0 165 165 0.3 0 0.7 0.2 04/28/2006 08:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 32 0 165 165 0.3 0 0.7 0.2 04/28/2006 08:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 32 0 165 165 0.5 0.1 0.9 0.2 04/28/2006 08:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 32 0 165 165 0.9 0 1.4 0.7 04/28/2006 08:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 32 0 165 165 1.3 0 1.4 1.1 04/28/2006 08:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 32 0 165 165 1.3 0 1.6 0.9 04/28/2006 09:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 32 0 165 165 1.1 0 1.4 0.9 04/28/2006 09:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 32 0 165 165 1.4 0 1.6 1.4 04/28/2006 09:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 32 0 165 165 1.5 0 1.8 1.4 04/28/2006 09:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 32 0 165 165 1.7 0 1.8 1.6 04/28/2006 09:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 33 0 165 165 1.7 0 1.8 1.6 04/28/2006 09:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 1 165 165 1.8 0 1.8 1.6 04/28/2006 10:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 37 0 165 165 1.8 0 1.8 1.6 04/28/2006 10:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 38 0 165 165 1.8 0 1.8 1.6 04/28/2006 10:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 38 0 165 165 1.9 0 2.1 1.6 04/28/2006 10:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 38 0 165 165 2 0 2.3 1.8 04/28/2006 10:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 39 0 165 165 2.1 0 2.3 1.8 04/28/2006 10:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 47 10 165 165 2.1 0 2.3 1.8 04/28/2006 11:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 65 0 165 165 2.3 0.1 2.8 1.8 04/28/2006 11:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 83 17 165 165 2.6 0.1 2.8 1.8 04/28/2006 11:20:00 0.4 0 0.4 0.4 2 0.6 3 0.4 0.4 0 0.4 0.4 107 7 165 165 2.9 0 3.3 2.6 04/28/2006 11:30:00 0.4 0 0.4 0.4 2.2 0.4 3 1.1 0.5 0.5 2.6 0.4 108 5 165 165 3.3 0.2 3.5 2.8 04/28/2006 11:40:00 1.2 1 3 0.4 2.2 0.4 3 1.1 2.3 0.5 3.8 1.1 109 7 111 165 3.6 0.3 4.3 2.8 04/28/2006 11:50:00 2.6 0.4 3.4 1.5 2.6 0.5 3.4 1.1 2.7 0.4 3.8 1.5 111 10 115 165 4 0.1 4.3 3.5 04/28/2006 12:00:00 2.9 0.4 4.2 1.9 2.8 0.4 4.2 1.5 3.1 0.4 4.2 2.3 113 6 108 165 3.8 0.1 4.3 3.3 04/28/2006 12:10:00 2.6 0.4 3.8 1.5 2.4 0.4 3.8 1.1 2.6 0.4 3.8 1.5 112 9 108 165 3.8 0 4 3.5 04/28/2006 12:20:00 2.1 0.4 3 0.7 1.8 0.5 3 0.4 2.2 0.4 3 0.7 116 12 110 165 4 0.2 4.3 3.3 04/28/2006 12:30:00 1.9 0.4 3 1.1 1.4 0.5 2.3 0.4 1.9 0.5 3 1.1 124 7 129 165 4 0.1 4.8 3.3 04/28/2006 12:40:00 1.8 0.5 2.6 0.4 1.1 0.6 2.6 0.4 1.6 0.5 3 0.4 146 11 143 165 4.3 0.3 5.2 3.5 04/28/2006 12:50:00 0.5 0.4 1.9 0.4 0.4 0.1 1.5 0.4 0.5 0.4 1.9 0.4 75 51 148 165 5.8 0.4 6.5 5 04/28/2006 13:00:00 0.9 0.6 2.3 0.4 0.7 0.5 2.3 0.4 0.7 0.5 2.3 0.4 109 38 142 165 6.9 0.2 7.3 6.5 04/28/2006 13:10:00 1.1 0.6 2.6 0.4 0.8 0.5 2.6 0.4 1 0.6 2.3 0.4 92 35 68 165 6.2 0.5 7.3 5.7 04/28/2006 13:20:00 1.6 0.6 3 0.4 1 0.7 2.6 0.4 1.5 0.7 3 0.4 73 30 30 165 6.1 0.2 6.7 5.7 04/28/2006 13:30:00 1.8 0.4 3 0.4 1.1 0.6 2.6 0.4 1.6 0.3 2.6 0.4 31 22 37 165 5.9 0.4 6.7 5.5 04/28/2006 13:40:00 2 0.5 3.4 0.4 1.9 0.6 3.4 0.4 2 0.6 3.4 0.7 50 35 126 165 5.9 0.4 7 5 04/28/2006 13:50:00 1.7 0.5 3 0.7 1.7 0.5 3 0.4 1.6 0.6 3.4 0.4 97 30 135 165 5.4 0.2 5.7 5 04/28/2006 14:00:00 2.6 0.8 4.9 0.7 2.6 0.8 4.9 0.7 2.5 0.7 4.6 0.4 76 24 61 165 4.6 0.4 5.7 4.3 04/28/2006 14:10:00 3.1 0.5 4.2 1.9 3.1 0.5 4.2 1.9 3 0.5 4.2 1.5 46 15 43 165 4.1 0.5 4.8 3.3 04/28/2006 14:20:00 3.5 0.6 4.6 1.9 3.4 0.6 4.6 1.9 3.4 0.6 4.6 1.9 33 9 19 165 4 0.4 4.8 3.3 04/28/2006 14:30:00 3.4 0.6 5.3 1.9 3.2 0.6 5.7 1.9 3.4 0.6 6.5 1.9 27 10 13 165 4.4 0.4 5 3.5 04/28/2006 14:40:00 4.2 0.6 6.1 3 4.1 0.8 6.1 1.9 4.3 0.7 6.1 3 23 9 29 165 4 0.4 4.5 2.8 04/28/2006 14:50:00 4.4 0.7 6.8 2.6 4.3 0.7 6.8 2.6 4.4 0.8 6.8 2.3 30 9 28 165 3.5 0.2 4.3 3 04/28/2006 15:00:00 5.1 0.8 7.2 3 5.1 0.8 7.2 3 5.2 0.8 7.2 2.6 32 8 34 165 3.5 0.2 4 2.6 04/28/2006 15:10:00 4.5 0.7 6.1 2.6 4.3 0.8 6.1 1.9 4.6 0.8 6.5 2.6 24 10 28 165 4.1 0.7 5.2 2.8 04/28/2006 15:20:00 4.3 0.6 5.7 3 4.1 0.8 5.7 2.3 4.3 0.6 6.1 2.6 27 11 39 165 3.6 0.7 5 2.6 04/28/2006 15:30:00 4.8 0.8 6.8 2.6 4.3 0.9 6.5 2.3 4.8 0.9 7.2 2.6 18 10 20 165 4.6 0.7 5.7 3.3 04/28/2006 15:40:00 4.1 0.7 6.1 2.6 3.9 0.7 5.7 1.9 4.1 0.6 6.1 2.6 22 8 19 165 3.8 0.3 4.5 3.3 04/28/2006 15:50:00 4.3 1 6.8 2.3 4 1.1 6.5 1.9 4.2 1 6.5 2.3 23 10 18 165 3.9 0.3 4.5 3.3 04/28/2006 16:00:00 4.7 0.5 5.7 3.4 4.5 0.6 5.7 3 4.5 0.6 5.7 3 22 6 25 165 3.6 0.3 4.5 3 04/28/2006 16:10:00 4.9 0.6 6.1 3.4 4.7 0.7 6.5 3 4.9 0.6 6.1 3 23 9 22 165 3.2 0.3 3.8 2.6 04/28/2006 16:20:00 4.4 0.7 6.1 3 4.3 0.7 6.1 3 4.4 0.7 6.1 2.6 28 7 8 165 3.7 0.6 4.5 2.3 04/28/2006 16:30:00 4.3 0.7 6.5 2.3 4 0.9 6.1 1.9 4.4 0.7 6.1 2.3 21 11 31 165 4.7 0.1 5 4.3 04/28/2006 16:40:00 4.6 0.6 6.1 3 4 0.9 6.1 1.9 4.5 0.7 6.5 3 16 10 10 165 5.3 0.1 5.7 5 04/28/2006 16:50:00 5.8 0.7 7.6 3.8 5.4 0.9 7.2 3 5.9 0.7 7.6 3.8 21 7 12 165 5.2 0.1 6 4.8 04/28/2006 17:00:00 5.9 0.7 7.6 3.8 4.7 0.8 6.5 2.6 6.1 0.7 8 3.8 13 7 3 165 4.6 0.1 5 4.3 04/28/2006 17:10:00 6.1 0.7 7.6 4.2 4.9 1 6.8 2.6 6.2 0.8 8.4 4.2 11 8 15 165 5.1 0.2 5.7 4.8 04/28/2006 17:20:00 6.5 0.8 8.4 3.8 5.8 1.3 8 2.6 6.6 0.8 8.8 4.2 17 9 6 165 4.8 0.6 5.7 4.3 04/28/2006 17:30:00 6 0.9 8 3.8 5.8 0.9 8 2.6 5.8 1 8.4 3.8 25 8 20 165 4.4 0 4.8 4.3 04/28/2006 17:40:00 6 0.9 8 3.4 5.7 1 8 2.6 5.8 0.9 7.6 3.4 25 9 32 165 4.2 0.1 4.5 3.8 04/28/2006 17:50:00 6.3 0.5 7.6 4.6 6.2 0.7 7.6 3 6.2 0.6 7.6 4.6 29 6 37 165 4 0 4.3 3.8 04/28/2006 18:00:00 6.1 1 8.8 3.4 5.9 1.1 8.4 2.6 6 1 9.1 3 25 8 28 165 4.1 0 4.3 3.8 04/28/2006 18:10:00 6.6 0.7 8 3.8 6.5 0.8 8 3 6.4 0.7 8 4.2 25 5 18 165 4.1 0 4.3 3.5 04/28/2006 18:20:00 6.1 0.8 8 3.8 5.6 1 8 3 5.9 0.9 8 3.8 19 9 19 165 4.2 0.1 4.5 3.5 04/28/2006 18:30:00 5.3 0.8 7.6 3.4 4.9 0.9 7.6 2.6 5.2 0.8 7.6 3.4 20 10 37 165 4.4 0.3 5 3.5 04/28/2006 18:40:00 5.8 0.8 7.6 3.8 5.7 0.8 7.6 3.4 5.7 0.8 8 3.8 32 6 29 165 3.8 0.1 4.3 3.3 04/28/2006 18:50:00 5.8 0.7 7.6 3.8 5.8 0.8 7.2 3.4 5.6 0.8 7.2 4.2 31 7 27 165 3.4 0.2 3.8 2.8 04/28/2006 19:00:00 6.6 0.7 8.4 4.6 6.5 0.8 8.4 4.6 6.3 0.9 8 3.8 32 7 36 165 2.9 0.1 3.3 2.3 04/28/2006 19:10:00 7.3 0.6 8.8 5.3 7.3 0.7 9.1 5.3 7.1 0.8 8.8 4.9 38 5 38 165 2.7 0 2.8 2.3 04/28/2006 19:20:00 7.1 1 9.5 4.9 7 1.1 9.5 4.2 6.8 1.1 9.1 4.6 31 6 29 165 2.4 0.1 2.8 1.8 04/28/2006 19:30:00 6 0.7 7.6 4.2 5 1.1 7.6 2.3 6 0.8 7.6 3.4 14 6 27 165 2.1 0.1 2.3 1.8 04/28/2006 19:40:00 5.1 0.6 6.5 3.8 3.7 0.7 5.3 2.3 4.9 0.6 6.8 3.4 10 4 6 165 1.8 0.1 2.1 1.6 04/28/2006 19:50:00 5 0.5 6.5 3.8 3.2 0.7 5.7 1.9 4.8 0.5 6.5 3.8 5 5 12 165 1.8 0.2 1.8 1.4 04/28/2006 20:00:00 6.5 0.8 9.1 4.9 4.5 1 8.8 2.6 6.4 0.9 8.8 4.2 5 7 360 165 2 0.1 2.3 1.6 04/28/2006 20:10:00 6.6 0.8 9.1 4.9 4.5 1.1 7.6 2.3 6.5 0.7 8.4 4.9 4 6 12 165 2 0 2.3 1.6 04/28/2006 20:20:00 4.5 0.8 6.1 2.3 3.6 0.8 5.7 1.5 4.2 0.8 6.5 2.3 8 11 1 165 2.1 0 2.3 1.6 04/28/2006 20:30:00 5.5 0.7 7.2 3.4 4.9 0.9 6.5 1.9 5.5 0.7 7.2 3.8 16 7 12 165 2 0.1 2.3 1.8 04/28/2006 20:40:00 6.7 1 9.1 4.6 5 1 7.6 2.6 6.4 1 8.8 4.6 8 7 2 165 1.7 0.1 1.8 1.4 04/28/2006 20:50:00 6.9 1.3 10.3 4.6 5.2 1.6 9.9 2.6 6.6 1.2 10.3 4.2 358 8 354 165 1.8 0.1 1.8 1.4 04/28/2006 21:00:00 7.7 1.3 11.5 4.9 5.9 1.7 11.5 3 7.6 1.2 11.1 5.3 356 7 347 165 1.9 0.1 2.1 1.6 04/28/2006 21:10:00 7.4 1 10.3 5.3 5.5 1.4 10.3 3 7.3 1.1 10.3 4.6 3 9 349 165 2 0.1 2.3 1.4 04/28/2006 21:20:00 7.2 1 9.9 5.3 4.8 1.1 8.4 2.6 7.1 1 9.9 4.9 6 5 5 165 1.9 0 2.1 1.6 04/28/2006 21:30:00 8 1 9.9 4.9 5.5 1.1 9.1 3 8.1 1 10.3 5.7 3 7 3 165 1.9 0 2.1 1.6 04/28/2006 21:40:00 7.4 0.9 9.5 5.3 5.7 1.3 8.8 3 7.3 1 10.7 5.3 355 7 343 165 1.8 0 1.8 1.6 04/28/2006 21:50:00 8.3 0.8 10.7 6.1 7.6 1.2 10.7 4.2 8.1 0.9 10.3 5.3 350 6 358 165 1.9 0 2.1 1.4 04/28/2006 22:00:00 9.4 1 11.5 6.5 8.4 1.5 11.8 4.6 9 1.2 11.8 5.7 351 5 354 165 2 0 2.3 1.6 04/28/2006 22:10:00 10.8 1.5 14.5 6.5 8.1 1.7 13 4.9 11 1.7 15.3 6.5 357 7 7 165 2.2 0 2.3 1.8 04/28/2006 22:20:00 9.7 1 13 6.8 8.3 1.6 12.2 4.9 9.5 1.1 12.6 6.8 352 7 359 165 2.2 0 2.3 1.6 04/28/2006 22:30:00 10.5 1.2 14.9 8.4 7.8 1.6 12.2 4.6 10.6 1.2 14.1 7.2 358 6 6 165 2.1 0 2.3 1.8 04/28/2006 22:40:00 9.4 1.1 12.6 6.8 8.3 1.7 13.3 4.6 9 1.3 13 6.5 351 8 343 165 1.8 0.1 2.3 1.4 04/28/2006 22:50:00 11.6 1.7 15.3 7.2 9.1 1.8 13.3 5.3 11.2 1.7 15.3 7.2 356 10 7 165 1.8 0.1 2.1 1.4 04/28/2006 23:00:00 12 1.2 15.3 9.5 8.6 1.9 13.7 5.3 11.8 1.2 14.9 8.4 358 6 1 165 2.1 0 2.3 1.8 04/28/2006 23:10:00 11.5 1.3 16.4 7.2 8.5 1.7 13.3 4.9 11.3 1.2 14.9 7.6 359 7 3 165 2.2 0 2.3 1.8 04/28/2006 23:20:00 11.3 1.9 16.8 7.2 8.4 2.3 15.6 3.8 11.2 1.8 16.8 7.2 0 8 351 165 2.3 0 2.3 1.8 04/28/2006 23:30:00 7.4 1.3 10.3 4.9 6.4 1.5 9.9 3 7.2 1.4 10.7 4.2 13 9 355 165 1.8 0.1 2.3 1.6 04/28/2006 23:40:00 10.1 2 16.8 6.8 7.9 1.8 13.7 4.2 9.6 2.1 16.8 6.1 6 9 354 165 1.4 0.1 1.6 1.4 04/28/2006 23:50:00 11.4 1.6 16.1 8 8.9 1.8 15.6 4.9 11.1 1.6 14.9 6.8 4 9 350 165 1.4 0 1.6 1.4 04/29/2006 00:00:00 10 1.3 15.3 8 7.3 1.4 11.8 4.9 9.9 1.2 14.5 8 5 7 359 165 1.3 0 1.4 1.1 04/29/2006 00:10:00 9 1.7 14.5 6.1 7.5 1.6 11.8 3.8 8.7 1.7 13.3 5.3 355 9 2 165 1.3 0 1.6 1.1 04/29/2006 00:20:00 9.6 1.5 14.9 6.8 8.7 1.4 12.6 5.7 9 1.5 13.3 5.7 351 9 4 165 1.4 0 1.6 1.4 04/29/2006 00:30:00 9.4 1.2 13.7 6.8 7.6 1.5 11.8 3.8 9.2 1.2 13 6.5 357 8 357 165 1.4 0 1.4 1.4 04/29/2006 00:40:00 7.7 0.8 10.3 6.1 7 1.4 9.9 3.4 7.4 0.7 9.1 5.7 350 8 351 165 1.3 0 1.4 1.1 04/29/2006 00:50:00 8.3 0.7 10.7 6.1 7.6 1.2 9.9 3.8 8 0.6 10.3 6.1 350 6 355 165 1.2 0 1.4 1.1 04/29/2006 01:00:00 8.5 0.9 11.5 6.1 7.9 1.1 11.1 4.2 8.1 0.9 10.3 5.7 345 9 353 165 1.3 0 1.4 1.4 04/29/2006 01:10:00 8.7 0.9 10.7 6.5 7.9 1.5 11.1 4.2 8.4 1 10.3 5.7 351 7 6 165 1.4 0 1.6 1.4 04/29/2006 01:20:00 6.8 1.1 9.9 4.6 5.5 1.3 9.1 2.6 6.4 1.1 9.9 3.8 353 12 1 165 1.4 0 1.6 1.4 04/29/2006 01:30:00 8.3 1.3 11.8 4.9 6.3 1.2 9.5 3.4 7.9 1.3 11.5 4.9 358 8 1 165 1.5 0 1.6 1.4 04/29/2006 01:40:00 9 1 12.2 6.5 6.5 1.3 11.5 4.2 8.7 1 11.5 6.1 4 7 2 165 1.4 0 1.6 1.4 04/29/2006 01:50:00 7.4 0.9 9.5 5.3 5.4 1.3 9.1 3 7.1 0.9 9.5 5.3 6 8 2 165 1.4 0 1.6 1.4 04/29/2006 02:00:00 8.5 1.1 12.2 4.6 6.6 1.5 10.3 3.8 8.2 1 11.1 5.7 9 8 8 165 1.5 0 1.6 1.4 04/29/2006 02:10:00 8.1 0.7 9.5 6.1 5.6 1 9.1 3 7.9 0.8 9.9 4.9 7 6 1 165 1.6 0 1.8 1.4 04/29/2006 02:20:00 6.6 0.8 9.1 4.9 4.6 0.9 6.8 2.6 6.3 0.7 8.8 4.9 3 8 1 165 1.6 0 1.6 1.4 04/29/2006 02:30:00 7.1 0.8 9.1 4.9 5.9 1.3 8.8 3 6.7 0.8 8.8 4.2 353 8 357 165 1.6 0 1.8 1.4 04/29/2006 02:40:00 5 1 7.6 3 4.2 0.9 6.8 1.5 4.5 0.8 7.6 3 351 12 5 165 1.4 0 1.6 1.4 04/29/2006 02:50:00 5.2 1.6 8.8 1.5 4.5 1.5 8.4 1.1 4.6 1.3 8 1.5 18 20 16 165 1.4 0 1.6 1.4 04/29/2006 03:00:00 5.7 1.6 9.5 1.5 5 1.7 9.1 1.5 5.1 1.5 8 1.5 14 15 31 165 1.5 0 1.6 1.4 04/29/2006 03:10:00 6.5 0.9 8.8 4.6 6 0.9 8.4 3.8 6.1 0.9 8.4 4.2 24 9 37 165 1.4 0.1 1.6 1.4 04/29/2006 03:20:00 6.9 1 9.9 4.9 6.8 1.1 9.9 4.2 6.7 0.8 9.1 4.9 27 7 26 165 1.3 0 1.6 1.1 04/29/2006 03:30:00 8 0.7 9.9 6.1 7.8 0.8 9.9 5.3 7.7 0.8 9.5 4.9 25 5 25 165 1.1 0 1.4 0.9 04/29/2006 03:40:00 7.9 0.5 9.1 6.5 6.8 1 8.8 3.8 7.8 0.6 9.1 6.1 14 4 12 165 1.2 0 1.4 1.1 04/29/2006 03:50:00 6.5 0.7 8 4.6 5.5 0.9 7.6 3 6.4 0.8 8.4 3.8 16 6 11 165 1.1 0 1.4 0.9 04/29/2006 04:00:00 6.9 0.8 8.4 4.9 4.9 1.2 8 2.6 6.9 0.7 8.4 4.9 6 6 11 165 1.2 0 1.4 1.1 04/29/2006 04:10:00 6.2 1.1 9.1 2.6 4.4 1.1 7.6 2.3 5.9 1.1 8.8 3.4 357 9 354 165 1.2 0 1.4 1.1 04/29/2006 04:20:00 6.2 1.3 8.4 2.3 5.2 1.2 8 2.3 6.1 1.2 8 2.6 351 9 3 165 1.2 0 1.4 1.1 04/29/2006 04:30:00 6.9 1 10.7 4.9 6 1.3 10.3 3 6.6 0.9 9.9 4.6 350 8 355 165 1.3 0 1.4 1.1 04/29/2006 04:40:00 7.9 0.7 10.7 6.1 6.2 1.5 9.1 3.4 7.5 0.8 10.3 4.9 354 6 5 165 1.4 0 1.4 1.1 04/29/2006 04:50:00 6.8 0.8 9.5 4.2 5.6 1.2 8.4 3 6.6 0.8 8.8 4.2 353 7 353 165 1.4 0 1.4 1.4 04/29/2006 05:00:00 8 1.1 11.8 5.7 7.5 1.7 12.2 3.4 7.8 1 11.5 5.3 348 7 347 165 1.4 0 1.6 1.4 04/29/2006 05:10:00 8.7 1 11.8 6.1 8.4 1.4 11.5 4.6 8.3 1.1 11.5 5.7 343 8 338 165 1.3 0 1.4 1.1 04/29/2006 05:20:00 8.2 0.9 10.7 5.7 8.1 1 9.9 4.6 7.9 0.8 10.3 5.7 343 7 349 165 1.2 0 1.4 1.1 04/29/2006 05:30:00 10.6 1.2 13.3 8 10.1 1.4 13.7 6.5 10.4 1.3 13.3 7.2 346 7 347 165 1.1 0 1.4 0.9 04/29/2006 05:40:00 10.5 1 13.3 8.4 9.7 1.2 13.3 5.3 10.3 1 13.3 7.6 348 8 354 165 1 0 1.1 0.9 04/29/2006 05:50:00 9.4 1.4 13.3 6.8 8.7 1.2 12.2 5.3 9.2 1.4 13.3 6.5 344 10 3 165 1.1 0 1.4 0.9 04/29/2006 06:00:00 11 1.6 14.9 7.6 10.4 1.9 14.9 5.3 10.7 1.7 15.3 6.8 347 9 5 165 1.1 0 1.4 0.9 04/29/2006 06:10:00 10 1.3 13.3 7.2 9.9 1.3 13.7 6.8 9.7 1.4 13 6.8 341 7 346 165 1.1 0 1.4 0.9 04/29/2006 06:20:00 8.7 1.4 11.8 6.1 8.5 1.7 12.2 4.2 8.4 1.3 12.2 5.7 344 9 338 165 1.1 0 1.4 0.9 04/29/2006 06:30:00 8.8 0.9 11.8 6.8 7.5 1.3 10.3 4.2 8.8 1.1 12.6 6.5 353 8 2 165 1.2 0 1.4 0.9 04/29/2006 06:40:00 7.8 1 10.7 5.3 7.3 1.3 11.1 4.6 7.5 1 11.1 4.6 346 10 3 165 1.4 0 1.6 1.4 04/29/2006 06:50:00 8.7 1.2 11.5 5.3 7.7 1.4 10.7 4.2 8.5 1.1 11.5 5.7 351 11 354 165 1.4 0 1.6 1.4 04/29/2006 07:00:00 7.3 1.2 10.7 4.9 6.3 1.3 9.9 3 7.2 1.3 10.3 4.2 352 8 5 165 1.5 0 1.8 1.4 04/29/2006 07:10:00 7.5 1.3 11.5 4.6 6.7 1.6 12.2 3 7.4 1.3 10.7 4.2 349 8 359 165 1.7 0 1.8 1.6 04/29/2006 07:20:00 7.8 1 10.3 5.3 7.1 1.7 11.1 3 7.7 1 10.3 5.3 348 9 333 165 1.8 0 2.1 1.6 04/29/2006 07:30:00 7.5 1 10.3 4.9 6.5 1.3 10.3 3.4 7.6 1 10.3 4.9 350 10 354 165 1.9 0 2.1 1.8 04/29/2006 07:40:00 6.8 1.2 10.3 4.6 5.6 1.7 9.9 2.6 7 1.1 9.5 4.2 352 9 349 165 1.9 0 2.1 1.8 04/29/2006 07:50:00 6.4 0.8 9.1 4.6 5.9 1.3 9.9 2.3 6.3 0.9 9.1 3.8 347 9 350 165 2 0 2.3 1.8 04/29/2006 08:00:00 6.7 0.7 9.1 4.6 5.6 1.1 7.6 2.6 6.6 0.9 8.8 4.6 349 13 357 165 2.1 0 2.3 2.1 04/29/2006 08:10:00 5.6 0.7 7.6 3.8 5.3 0.8 7.6 2.6 5.5 0.7 8 3.8 336 11 351 165 2.3 0 2.6 2.1 04/29/2006 08:20:00 6.2 1.4 10.7 2.6 5.9 1.5 10.7 2.3 6.1 1.4 10.3 2.6 340 12 343 165 2.4 0 2.6 2.3 04/29/2006 08:30:00 6.3 1 9.1 4.2 6.2 1 8.8 3.4 6.3 1 9.1 4.2 330 9 331 165 2.6 0 2.8 2.3 04/29/2006 08:40:00 7.4 1 9.9 4.9 7.3 1 9.5 4.9 7.3 1 9.9 4.9 327 9 328 165 2.9 0 3 2.6 04/29/2006 08:50:00 6.8 0.9 9.9 5.3 6.8 0.9 9.5 5.3 6.8 1 10.7 4.6 321 8 319 165 2.9 0 3 2.8 04/29/2006 09:00:00 6.6 0.8 9.5 4.6 6.5 0.8 9.1 4.2 6.6 0.9 9.5 4.6 331 9 333 165 2.7 0 3 2.6 04/29/2006 09:10:00 6.2 0.8 8 3.4 6.1 0.9 8.4 3 6.1 0.9 8 3.4 326 11 341 165 2.8 0 3 2.6 04/29/2006 09:20:00 7.1 0.8 9.1 4.2 7 0.9 9.1 3.8 7.1 0.9 9.5 4.6 336 12 319 165 2.9 0 3 2.6 04/29/2006 09:30:00 6.4 0.7 8 4.6 6.4 0.7 8.4 4.9 6.4 0.7 8.4 4.9 331 9 332 165 3 0 3.3 2.8 04/29/2006 09:40:00 6.5 1.3 10.3 3.8 6.5 1.4 10.7 4.2 6.4 1.5 10.3 3.4 332 10 339 165 3.1 0 3.3 2.8 04/29/2006 09:50:00 5.9 1.1 9.1 3.8 6 1.1 9.5 3 6 0.9 8.8 4.2 332 10 328 165 3.7 0.3 4.3 3 04/29/2006 10:00:00 5.8 0.8 7.2 3 5.8 0.8 7.6 2.6 5.6 0.8 8.4 3.4 328 13 309 165 4.4 0.2 5 4.3 04/29/2006 10:10:00 5.9 0.8 8 3 5.8 0.8 8.4 2.6 5.9 0.8 8 3.8 332 9 314 165 4.7 0.3 5.2 3.8 04/29/2006 10:20:00 7.6 0.9 10.3 5.7 7.5 0.9 10.7 5.7 7.5 1 10.7 4.9 331 8 344 165 4.8 0.2 5.2 4.5 04/29/2006 10:30:00 7.2 1 9.1 4.9 7 1.2 9.5 4.2 7.2 1 9.1 4.6 338 10 336 165 4.6 0.2 5.2 4.3 04/29/2006 10:40:00 6 1.2 8.4 3.4 5.9 1.2 8.8 3.4 5.8 1.3 9.5 3 330 11 335 165 5.4 0.3 6 4.8 04/29/2006 10:50:00 5.3 0.9 7.6 3.4 5.3 0.9 8 3.4 5.2 1 8 3 325 15 335 165 5.8 0.3 6.2 5 04/29/2006 11:00:00 5.3 1 7.2 2.6 5.2 1 7.6 2.6 4.9 0.8 6.8 3 322 11 307 165 5.1 0.2 5.5 4.8 04/29/2006 11:10:00 5.8 1 9.1 3.4 5.7 1 9.1 3.4 5.2 1 8.4 2.6 314 13 304 165 5.5 0.4 6 4.8 04/29/2006 11:20:00 6.1 0.8 8 4.2 6.1 0.8 8 4.2 5.2 0.8 7.6 3 307 9 305 165 5.5 0.3 6 5 04/29/2006 11:30:00 8 1.2 10.3 4.9 8 1.2 10.7 4.9 7.2 1.6 10.3 3.8 313 11 302 165 5.1 0.3 6 4.8 04/29/2006 11:40:00 7.3 1.3 10.3 4.6 7.3 1.3 10.7 4.6 7.2 1.3 11.1 4.9 327 11 326 165 5.6 0.3 6.2 5 04/29/2006 11:50:00 8.5 0.8 10.3 6.5 8.4 0.8 10.3 6.8 7.8 0.9 9.5 5.3 314 5 309 165 5.4 0.3 6 5 04/29/2006 12:00:00 8.7 0.6 9.9 6.5 8.6 0.6 9.9 6.5 8.5 0.6 9.9 6.5 323 9 332 165 5.3 0.1 5.7 4.8 04/29/2006 12:10:00 9.2 0.7 11.5 7.2 9.2 0.7 11.5 7.2 8.6 0.7 10.7 6.5 314 5 307 165 5.3 0.2 5.7 4.8 04/29/2006 12:20:00 10.2 0.7 12.6 8.4 10.2 0.6 12.2 8.4 8.9 1 11.5 5.3 309 6 310 165 4.9 0 5.2 4.8 04/29/2006 12:30:00 10.3 0.9 12.2 8 10.2 0.9 11.8 7.6 9.9 1 12.6 6.8 316 5 322 165 5.1 0.1 5.2 4.5 04/29/2006 12:40:00 9.9 0.7 11.8 7.2 9.8 0.7 11.5 6.8 9.6 0.9 11.5 6.8 318 6 312 165 5.4 0.1 5.7 4.8 04/29/2006 12:50:00 10.3 0.8 12.2 7.6 10.2 0.7 11.8 7.6 10 0.8 12.2 7.2 318 6 315 165 5.6 0.2 6 5 04/29/2006 13:00:00 9.9 0.7 11.5 7.6 9.8 0.7 11.5 8 9.2 1 11.5 6.5 315 7 315 165 5.5 0 5.7 5 04/29/2006 13:10:00 10.2 0.8 11.8 8 10.1 0.8 11.8 7.6 9.2 0.9 11.1 6.5 311 5 300 165 5.1 0 5.5 4.5 04/29/2006 13:20:00 9.9 1 12.6 6.8 9.9 1 12.6 6.8 9 1.1 11.5 6.5 312 6 322 165 5.2 0 5.5 5 04/29/2006 13:30:00 10.1 0.7 11.8 7.2 10.1 0.7 11.5 7.2 9 1 11.5 6.5 311 5 307 165 5.2 0 5.5 5 04/29/2006 13:40:00 10.4 0.6 12.6 8.8 10.4 0.6 12.2 8.8 9.9 0.8 11.8 7.6 314 5 311 165 5.2 0 5.5 5 04/29/2006 13:50:00 9 0.7 10.7 6.5 8.9 0.7 10.7 6.5 8.8 0.8 10.7 6.5 318 6 320 165 5.6 0.2 6 5.2 04/29/2006 14:00:00 9.1 0.8 11.1 6.5 9 0.8 11.1 6.8 8.8 1 11.1 5.7 317 7 310 165 5.8 0.1 6.2 5.5 04/29/2006 14:10:00 8.6 1.3 11.5 5.7 8.5 1.3 11.5 5.7 7.9 0.9 9.9 5.7 315 9 305 165 6.1 0.2 6.2 5.5 04/29/2006 14:20:00 10.2 0.9 12.6 8 10.2 0.9 12.2 8.4 9.2 1.1 12.6 6.1 310 5 305 165 5.4 0 5.7 5.2 04/29/2006 14:30:00 9.9 1.2 12.6 6.8 9.9 1.2 12.6 6.5 8.9 1.2 12.6 6.1 312 7 310 165 5.6 0 5.7 5.2 04/29/2006 14:40:00 10 1.2 11.8 6.1 9.8 1.2 11.8 5.7 9.6 1.2 11.5 5.7 317 6 314 165 5.8 0.1 6 5.7 04/29/2006 14:50:00 9.7 0.8 11.5 7.2 9.6 0.8 11.5 6.8 9.5 1 11.8 6.1 316 6 317 165 5.8 0 6 5.5 04/29/2006 15:00:00 9.9 1 12.2 6.5 9.8 1 12.2 6.8 9.2 1.2 11.8 6.1 317 10 316 165 5.7 0 6 5.5 04/29/2006 15:10:00 9.4 1.2 11.8 6.1 9.4 1.2 11.8 6.1 8.9 1.3 11.5 5.7 315 8 310 165 5.6 0.1 6 5.2 04/29/2006 15:20:00 10.3 0.8 12.6 8 10.2 0.8 12.6 7.6 10 0.9 11.8 7.2 317 7 310 165 5.5 0.2 6 4.8 04/29/2006 15:30:00 9.7 1 11.8 6.8 9.6 1 11.8 6.5 9.2 1 12.2 6.1 318 7 324 165 5.6 0 6 5.5 04/29/2006 15:40:00 9.8 1 11.8 7.6 9.6 1 11.8 7.2 9.4 1 11.5 6.5 319 5 319 165 5.4 0 5.7 5.2 04/29/2006 15:50:00 8.3 1.1 10.7 4.6 8.1 1.1 11.1 4.6 7.8 1.2 10.7 4.2 321 8 331 165 5.7 0.1 6 5.2 04/29/2006 16:00:00 8.3 0.6 9.9 6.5 8.2 0.6 9.9 6.1 8 0.8 9.9 4.9 318 7 316 165 5.3 0.1 5.7 5 04/29/2006 16:10:00 9.1 0.9 11.5 6.8 9 0.9 11.1 6.5 8.7 1 11.1 5.7 320 8 328 165 5.3 0.1 5.7 5 04/29/2006 16:20:00 9.7 0.9 11.8 7.6 9.6 0.9 11.8 7.6 9.3 0.9 11.5 7.2 320 5 317 165 5.2 0 5.5 5 04/29/2006 16:30:00 9.4 0.7 11.5 6.8 9.3 0.7 11.5 6.1 9 0.9 11.1 6.8 321 7 323 165 5.2 0 5.5 5 04/29/2006 16:40:00 10.1 0.9 12.2 7.6 10 0.8 12.2 7.2 9.7 0.9 12.6 6.5 319 5 314 165 5.2 0 5.7 5 04/29/2006 16:50:00 11.3 0.8 13.3 8.4 11.1 0.8 13 8.4 10.9 0.8 13.3 8.4 318 5 322 165 5.1 0 5.2 4.8 04/29/2006 17:00:00 9.9 1.3 12.2 6.1 9.7 1.2 11.8 5.7 9.3 1.3 11.8 5.3 320 7 315 165 5.1 0 5.2 4.8 04/29/2006 17:10:00 9.9 0.8 11.5 7.2 9.7 0.7 11.1 7.2 9.3 1 11.5 6.5 319 6 321 165 5 0 5.5 4.8 04/29/2006 17:20:00 10.1 0.8 11.8 6.8 9.9 0.8 11.8 7.2 9.7 1 12.6 7.2 318 4 325 165 4.8 0.1 5 4.3 04/29/2006 17:30:00 10.2 1 13 6.8 10.1 1 12.2 6.5 9.8 1.1 12.6 5.7 318 4 311 165 4.4 0 5 4.3 04/29/2006 17:40:00 9.4 1.1 12.2 6.8 9.3 1.1 12.2 6.8 9.1 1.2 12.2 6.1 320 5 322 165 4.4 0 4.8 4 04/29/2006 17:50:00 9 1 11.5 6.1 9 1.1 11.5 5.7 8.7 1.1 12.2 5.7 321 9 310 165 4.4 0 4.5 4 04/29/2006 18:00:00 7.4 0.6 9.1 5.7 7.4 0.6 9.5 5.7 7.1 0.8 8.8 4.2 317 9 288 165 4.4 0 4.8 4 04/29/2006 18:10:00 7.5 0.8 9.5 5.3 7.4 0.8 9.1 5.3 7 0.7 8.8 4.9 314 8 310 165 4.5 0 4.8 4 04/29/2006 18:20:00 7.2 1 10.3 4.9 7.1 1 9.9 4.9 7.1 1 9.9 4.2 324 9 321 165 4.7 0 5 4.5 04/29/2006 18:30:00 7.6 0.7 9.5 5.3 7.6 0.7 9.5 5.3 7.6 0.8 9.9 5.3 320 7 313 165 4.6 0.1 4.8 4.3 04/29/2006 18:40:00 7.1 0.7 8.8 4.9 7.1 0.8 9.1 4.6 6.8 0.7 8.4 4.6 322 14 325 165 4.4 0 4.8 3.8 04/29/2006 18:50:00 6 0.9 8.4 4.2 6 1 8.4 4.2 6 1 8.4 4.2 337 11 342 165 4.3 0 4.5 3.8 04/29/2006 19:00:00 6.4 0.8 9.1 4.2 6.1 1.2 9.5 2.6 6.4 0.8 9.5 4.6 346 9 336 165 4.1 0 4.5 4.3 04/29/2006 19:10:00 7 0.6 9.1 4.9 6.8 0.8 8.8 4.6 7 0.6 8.8 5.3 343 9 354 165 4 0 4.3 3.8 04/29/2006 19:20:00 7.4 1 10.3 5.3 7.3 0.9 9.9 5.7 7.1 0.9 9.9 4.9 330 8 335 165 3.9 0 4.3 3.5 04/29/2006 19:30:00 8 0.7 9.5 5.7 7.9 0.7 9.5 5.7 7.5 0.7 9.1 4.6 317 7 307 165 4 0 4.3 3.5 04/29/2006 19:40:00 7.1 0.6 8.4 5.3 7 0.6 8.4 5.3 6.4 0.7 8 4.6 315 6 314 165 4 0 4.3 3.3 04/29/2006 19:50:00 7 0.5 8.4 5.3 6.9 0.5 8.4 5.3 6.2 0.6 7.6 4.2 312 4 309 165 3.8 0 4 3.5 04/29/2006 20:00:00 7.7 0.8 9.5 5.7 7.7 0.8 9.5 5.7 6.2 0.8 8.4 4.2 307 4 316 165 3.8 0 4 3.5 04/29/2006 20:10:00 8.2 0.7 9.9 6.5 8.2 0.7 9.9 6.5 7 0.7 8.4 4.9 310 5 305 165 3.6 0 3.8 3.5 04/29/2006 20:20:00 6.7 1 9.1 4.6 6.7 1 9.5 4.6 6.1 0.8 8.4 4.2 320 12 307 165 3.5 0 3.8 3.3 04/29/2006 20:30:00 5.6 0.7 7.6 4.2 5.5 0.7 7.6 4.2 5.4 0.6 7.6 4.2 333 8 325 165 3 0.1 3.3 2.8 04/29/2006 20:40:00 6.8 0.7 9.1 4.9 6.7 0.7 8.4 4.9 6.5 0.7 8.4 4.6 336 9 346 165 3 0 3.3 2.8 04/29/2006 20:50:00 5.9 0.7 8 4.2 5.8 0.7 7.6 4.2 5.6 0.6 7.6 3.8 331 13 344 165 3 0 3.3 2.8 04/29/2006 21:00:00 5.8 0.7 7.2 4.2 5.7 0.7 7.2 3.8 5.8 0.6 7.2 4.2 329 9 310 165 2.8 0 3 2.6 04/29/2006 21:10:00 5.7 0.6 7.6 4.2 5.6 0.6 7.6 4.2 5.6 0.6 7.2 4.2 328 8 336 165 2.7 0 2.8 2.6 04/29/2006 21:20:00 5.9 0.9 8.8 3.8 5.9 1 9.1 3.8 5.8 1 8.4 3.4 333 11 341 165 2.9 0.1 3 2.6 04/29/2006 21:30:00 4.7 0.5 6.1 3.4 4.6 0.5 6.1 3.4 4.4 0.7 6.1 3 318 10 323 165 2.7 0 2.8 2.6 04/29/2006 21:40:00 6.3 0.9 8 4.2 6.3 1 8.4 4.2 4.7 0.7 6.8 2.6 301 5 302 165 2.6 0.1 3 2.3 04/29/2006 21:50:00 7.1 0.7 8.4 4.2 7.2 0.7 8.4 4.2 5.2 0.5 6.8 3.8 303 3 300 165 2.9 0 3 2.8 04/29/2006 22:00:00 6.1 0.8 7.6 3.8 6.1 0.8 8 3.8 4.9 0.8 7.2 3.4 307 6 307 165 2.9 0 3 2.8 04/29/2006 22:10:00 4.7 0.6 6.1 3.4 4.7 0.6 6.1 3 4 0.7 6.5 2.3 302 9 314 165 2.8 0 3 2.6 04/29/2006 22:20:00 5.5 0.6 7.2 4.2 5.5 0.7 7.2 3.8 4.9 0.7 7.6 3 298 9 285 165 2.6 0 2.8 2.6 04/29/2006 22:30:00 6.2 0.6 7.6 4.6 6.2 0.6 7.6 4.6 4.9 0.7 7.2 3.4 302 7 304 165 2.6 0 2.8 2.3 04/29/2006 22:40:00 5.6 0.7 7.2 4.2 5.7 0.6 7.2 4.2 4.6 0.9 7.6 2.6 303 9 313 165 2.7 0 2.8 2.6 04/29/2006 22:50:00 5.6 0.8 6.8 3.4 5.6 0.9 6.8 3 4.6 0.8 6.8 2.6 302 8 296 165 2.6 0 2.8 2.6 04/29/2006 23:00:00 4.5 0.9 7.2 3 4.4 0.9 7.2 2.6 4.1 0.7 6.1 2.3 317 11 317 165 2.4 0 2.6 2.3 04/29/2006 23:10:00 3.7 0.7 5.3 1.1 3.6 0.7 5.7 1.1 3.2 0.6 4.6 1.9 295 10 296 165 2.4 0 2.6 2.3 04/29/2006 23:20:00 3.5 0.6 4.9 1.1 3.5 0.6 4.9 0.7 3.5 0.6 4.9 1.5 290 11 287 165 2.5 0 2.8 2.3 04/29/2006 23:30:00 3.8 0.7 5.3 1.9 3.7 0.7 5.3 1.5 3.6 0.9 5.3 1.9 304 14 288 165 2.7 0 2.8 2.6 04/29/2006 23:40:00 4.3 1 6.8 1.9 4.2 1 6.8 1.9 3.6 0.8 6.5 1.5 306 7 294 165 2.7 0 2.8 2.6 04/29/2006 23:50:00 6.1 1 8 3.4 6 1 8 3.4 5 0.8 6.8 3 306 6 303 165 2.4 0 2.8 2.3 04/30/2006 00:00:00 6.9 0.6 8.4 5.3 6.8 0.6 8.4 5.3 5.4 0.7 7.2 3.8 307 4 307 165 2.2 0 2.3 1.8 04/30/2006 00:10:00 6 0.8 7.6 4.2 6 0.8 7.6 4.2 4.4 0.5 5.7 3 303 4 300 165 2.3 0 2.6 2.1 04/30/2006 00:20:00 6.1 0.5 7.2 4.9 6.1 0.5 7.2 4.9 4.5 0.5 6.5 3.4 301 4 301 165 2.4 0 2.6 2.3 04/30/2006 00:30:00 5.8 0.6 6.8 3.4 5.8 0.6 7.2 3.4 4.7 0.6 6.5 3 297 6 307 165 2.4 0 2.6 2.3 04/30/2006 00:40:00 4.1 0.9 7.6 2.3 4.1 0.9 7.6 2.3 3.5 0.7 6.8 2.3 303 11 287 165 2.4 0 2.8 2.3 04/30/2006 00:50:00 2.2 0.6 3.4 0.7 1.9 0.6 3.4 0.4 2.1 0.5 3 0.7 327 24 312 165 2.1 0 2.6 1.8 04/30/2006 01:00:00 2.4 0.8 4.9 0.7 1.7 0.9 4.6 0.4 2.5 0.8 4.2 0.7 351 15 8 165 2.3 0 2.6 2.1 04/30/2006 01:10:00 1.1 0.5 2.3 0.4 0.5 0.4 1.9 0.4 0.9 0.5 2.3 0.4 341 29 356 165 2 0.1 2.6 1.8 04/30/2006 01:20:00 0.7 0.4 2.3 0.4 0.4 0.1 1.5 0.4 0.5 0.3 1.9 0.4 4 24 351 165 1.9 0 2.1 1.6 04/30/2006 01:30:00 0.7 0.4 1.5 0.4 0.4 0.2 1.5 0.4 0.5 0.3 1.5 0.4 29 12 355 165 1.9 0 2.1 1.8 04/30/2006 01:40:00 1 0.4 1.9 0.4 0.4 0.2 1.1 0.4 0.6 0.4 1.9 0.4 339 16 349 165 2 0 2.3 1.8 04/30/2006 01:50:00 1 0.4 1.9 0.4 0.4 0.2 1.1 0.4 0.8 0.4 1.9 0.4 322 17 307 165 2 0.1 2.3 1.8 04/30/2006 02:00:00 0.5 0.2 1.5 0.4 0.4 0 0.7 0.4 0.5 0.3 1.5 0.4 302 33 248 165 2.2 0.1 2.6 1.8 04/30/2006 02:10:00 1.4 0.7 3 0.4 1.1 0.7 3 0.4 1.6 0.7 3 0.4 260 13 272 165 2.4 0 2.6 2.3 04/30/2006 02:20:00 3.2 0.6 4.6 1.5 2.9 0.7 4.6 1.1 2.9 0.8 4.9 1.5 286 10 280 165 2.3 0 2.6 2.1 04/30/2006 02:30:00 2.6 0.5 3.8 1.1 2.3 0.6 3.4 0.4 2.5 0.5 3.4 1.5 289 13 302 165 2.3 0 2.6 2.3 04/30/2006 02:40:00 2.1 1 4.2 0.4 1.7 1.1 3.8 0.4 2 0.8 4.2 0.4 292 8 295 165 2.3 0 2.6 2.3 04/30/2006 02:50:00 3 0.4 3.8 1.9 2.7 0.5 3.8 1.5 2.4 0.5 3.8 1.1 298 7 288 165 2.3 0 2.6 2.1 04/30/2006 03:00:00 3 0.5 4.2 1.9 2.7 0.5 4.2 1.1 2.5 0.5 4.2 1.1 294 9 290 165 2.2 0 2.3 1.8 04/30/2006 03:10:00 2 0.8 3.4 0.7 1.4 1 3.4 0.4 1.8 0.8 3.4 0.4 298 12 286 165 2.3 0 2.6 2.1 04/30/2006 03:20:00 2.1 0.5 3.8 0.7 1.7 0.6 3.4 0.4 1.9 0.6 3.4 0.7 293 11 275 165 2.4 0.1 2.6 2.1 04/30/2006 03:30:00 1.3 0.6 2.3 0.4 0.8 0.5 2.3 0.4 1.4 0.4 2.6 0.4 290 15 300 165 2.4 0 2.6 2.3 04/30/2006 03:40:00 0.5 0.2 1.5 0.4 0.4 0 0.7 0.4 0.5 0.3 1.5 0.4 305 18 292 165 2.7 0 2.8 2.6 04/30/2006 03:50:00 0.4 0.1 1.1 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 320 0 320 165 2.5 0.1 2.8 2.3 04/30/2006 04:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 320 0 165 165 2.4 0.1 2.6 2.3 04/30/2006 04:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 320 0 165 165 2.4 0 2.6 2.3 04/30/2006 04:20:00 0.8 0.6 1.9 0.4 0.6 0.4 1.9 0.4 0.9 0.7 2.3 0.4 302 26 276 165 2.4 0 2.6 2.3 04/30/2006 04:30:00 2 0.4 3 1.1 1.7 0.5 3 0.7 2.1 0.5 3 1.1 281 6 272 165 2.3 0 2.6 2.3 04/30/2006 04:40:00 0.8 0.4 1.9 0.4 0.5 0.3 1.5 0.4 0.8 0.3 1.9 0.4 291 6 282 165 2.3 0 2.3 2.1 04/30/2006 04:50:00 0.7 0.3 1.5 0.4 0.4 0.1 1.1 0.4 0.7 0.3 1.5 0.4 291 5 294 165 2.3 0 2.6 2.1 04/30/2006 05:00:00 0.7 0.3 1.5 0.4 0.4 0.1 1.1 0.4 1 0.3 1.5 0.4 285 0 285 165 2.4 0 2.6 2.3 04/30/2006 05:10:00 0.6 0.4 1.5 0.4 0.4 0.2 1.1 0.4 0.7 0.3 1.5 0.4 285 0 284 165 2.5 0 2.6 2.3 04/30/2006 05:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0.1 0.7 0.4 285 0 165 165 2.4 0 2.8 2.3 04/30/2006 05:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 285 0 165 165 2.4 0 2.6 2.3 04/30/2006 05:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 285 0 165 165 2.1 0 2.3 1.8 04/30/2006 05:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0.1 0.7 0.4 229 30 165 165 2.5 0.1 3 2.3 04/30/2006 06:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 188 0 165 165 3.3 0.2 3.8 2.8 04/30/2006 06:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 188 0 165 165 4.1 0.1 4.5 3.5 04/30/2006 06:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 188 0 165 165 4.9 0 5.2 4.5 04/30/2006 06:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 188 0 165 165 5.7 0.3 6.2 5 04/30/2006 06:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 188 0 165 165 6.6 0.2 7.3 6.2 04/30/2006 06:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 188 0 165 165 7.7 0.3 8.5 7 04/30/2006 07:00:00 0.4 0.1 1.1 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 188 0 188 165 7.6 0.6 8.5 6.2 04/30/2006 07:10:00 0.4 0 0.7 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 188 0 188 165 6.1 0.3 7 5.7 04/30/2006 07:20:00 0.4 0.1 1.1 0.4 0.4 0 0.4 0.4 0.4 0.1 1.1 0.4 188 0 188 165 6.7 0.1 7.3 6 04/30/2006 07:30:00 0.4 0.2 1.1 0.4 0.4 0.1 1.1 0.4 0.4 0.1 0.7 0.4 168 8 164 165 5.7 0.4 6.7 5 04/30/2006 07:40:00 0.4 0.1 0.7 0.4 0.4 0.1 0.7 0.4 0.5 0.3 1.5 0.4 164 0 164 165 5 0.3 5.5 4.3 04/30/2006 07:50:00 0.4 0 0.7 0.4 0.4 0 0.4 0.4 0.4 0.1 1.1 0.4 164 0 164 165 4.1 0.1 4.5 4 04/30/2006 08:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 164 0 165 165 4.6 0.3 5 4.3 04/30/2006 08:10:00 0.6 0.2 1.1 0.4 0.5 0.2 1.1 0.4 0.4 0.2 1.1 0.4 164 0 164 165 4.5 0.1 5 4 04/30/2006 08:20:00 0.5 0.2 1.1 0.4 0.4 0.1 1.1 0.4 0.4 0.2 1.1 0.4 164 0 164 165 4 0 4.3 3.8 04/30/2006 08:30:00 1 0.3 1.5 0.4 0.8 0.3 1.5 0.4 0.8 0.3 1.5 0.4 152 9 156 165 4.1 0 4.5 3.8 04/30/2006 08:40:00 1.4 0.2 1.9 0.7 1.2 0.2 1.9 0.7 1.3 0.2 1.9 0.7 146 7 148 165 4 0 4.3 3.8 04/30/2006 08:50:00 1.5 0.3 2.3 0.7 1.4 0.3 2.3 0.7 1.4 0.3 2.3 0.7 141 8 132 165 3.8 0.1 4 3.5 04/30/2006 09:00:00 1.7 0.3 2.3 1.1 1.6 0.3 2.3 0.7 1.6 0.3 2.6 0.7 137 10 130 165 3.8 0.2 4.3 3.5 04/30/2006 09:10:00 1.9 0.2 2.3 1.1 1.7 0.3 2.3 1.1 1.8 0.3 2.6 1.1 136 5 135 165 4.1 0.1 4.5 3.8 04/30/2006 09:20:00 2.4 0.3 3 1.9 2.2 0.3 3 1.5 2.4 0.3 3 1.9 137 6 145 165 4.4 0 4.8 4.3 04/30/2006 09:30:00 2.9 0.4 4.2 1.9 2.7 0.4 4.2 1.9 2.7 0.4 4.2 1.9 135 8 138 165 5.1 0.2 5.5 4.5 04/30/2006 09:40:00 3.2 0.3 4.2 2.6 3 0.3 3.8 2.3 3.2 0.3 4.2 2.3 138 7 135 165 4.1 0.2 4.5 3.5 04/30/2006 09:50:00 3.3 0.4 4.2 2.3 3.1 0.4 4.2 1.9 3.3 0.4 4.6 2.3 143 10 133 165 4.5 0 4.8 4.3 04/30/2006 10:00:00 3.6 0.3 4.9 3 3.5 0.4 4.9 2.6 3.6 0.4 4.6 2.6 146 8 142 165 4.8 0.1 5 4.5 04/30/2006 10:10:00 4.2 0.5 5.7 3 4.1 0.5 5.3 3 4.1 0.5 5.3 3 148 7 147 165 4.6 0 4.8 4 04/30/2006 10:20:00 4.6 0.4 5.7 3.4 4.6 0.4 5.3 3.4 4.6 0.4 5.3 3.4 144 7 149 165 4.1 0 4.5 3.8 04/30/2006 10:30:00 4.5 0.4 5.3 3.8 4.5 0.4 5.7 3.8 4.4 0.4 5.3 3.4 140 6 139 165 4.2 0.3 4.8 3.5 04/30/2006 10:40:00 5 0.4 6.1 3.8 5 0.4 6.1 3.8 4.8 0.4 6.1 3.8 138 7 135 165 4.6 0 5 4.5 04/30/2006 10:50:00 5.2 0.6 7.2 3 5.3 0.7 7.6 3.4 5.2 0.6 7.2 3.8 140 11 135 165 4.6 0.2 5.2 4.3 04/30/2006 11:00:00 6.4 0.7 7.6 4.2 6.4 0.7 8 4.6 6.6 0.7 8.4 4.6 144 7 138 165 4.8 0.2 5.5 4.3 04/30/2006 11:10:00 7.6 0.5 9.1 6.5 7.6 0.5 9.1 6.5 7.6 0.5 8.8 6.1 142 5 145 165 4.4 0.2 5 3.8 04/30/2006 11:20:00 8.4 0.6 9.9 6.5 8.4 0.6 9.9 6.8 8.4 0.7 10.3 5.3 138 5 136 165 4.4 0.2 5 4.3 04/30/2006 11:30:00 8.1 0.6 9.1 6.1 8.1 0.6 9.5 6.5 8 0.7 9.5 5.7 136 6 136 165 4.5 0.4 5 3.8 04/30/2006 11:40:00 8.4 0.6 10.3 6.8 8.4 0.6 9.9 6.8 8.4 0.6 9.9 6.8 139 5 131 165 3.9 0 4.3 3.5 04/30/2006 11:50:00 8.4 0.8 11.1 6.5 8.4 0.8 11.1 6.5 8.6 0.9 11.5 6.5 142 5 139 165 4.5 0.4 5 3.5 04/30/2006 12:00:00 8.2 0.8 10.3 6.5 8.3 0.8 10.7 6.1 8.4 0.8 10.7 6.1 140 7 148 165 4.4 0.3 5 3.5 04/30/2006 12:10:00 7.6 0.6 9.1 6.1 7.6 0.6 9.1 6.1 7.6 0.7 9.9 5.7 142 7 146 165 4.5 0.1 4.8 3.8 04/30/2006 12:20:00 7.8 0.6 9.9 6.1 7.8 0.7 10.3 6.1 7.9 0.7 10.3 5.7 142 7 142 165 4.6 0.1 5 4.3 04/30/2006 12:30:00 7.6 0.5 9.1 6.1 7.6 0.6 9.1 6.5 7.7 0.7 9.9 6.1 140 7 143 165 4.6 0.1 5 4.3 04/30/2006 12:40:00 7.6 0.6 8.8 6.1 7.6 0.6 8.8 5.7 7.7 0.7 9.1 5.3 140 8 146 165 4.8 0.1 5 4.5 04/30/2006 12:50:00 8.1 0.5 9.1 6.5 8.1 0.5 9.5 6.8 8.2 0.5 9.5 6.5 137 5 136 165 4.3 0.2 4.8 3.8 04/30/2006 13:00:00 8.3 0.4 9.5 6.8 8.3 0.4 9.5 6.8 8.4 0.5 9.9 7.2 139 5 149 165 4.4 0.3 4.8 4 04/30/2006 13:10:00 7.7 0.7 9.5 5.3 7.7 0.7 9.5 5.3 7.7 0.7 9.5 6.1 140 8 138 165 5.1 0.2 5.5 4.3 04/30/2006 13:20:00 7.9 0.4 9.5 6.5 7.8 0.4 8.8 6.1 8.1 0.5 9.9 6.5 153 5 164 165 5.1 0 5.2 5 04/30/2006 13:30:00 8.5 0.8 9.9 6.8 8.3 0.7 9.9 6.8 8.8 0.8 10.7 6.8 157 9 157 165 5.1 0 5.5 4.8 04/30/2006 13:40:00 8.4 0.5 9.5 7.2 8.2 0.5 9.5 6.8 8.6 0.5 9.5 7.2 165 5 165 165 4.8 0 5 4.5 04/30/2006 13:50:00 8.2 0.5 9.1 6.5 8 0.5 9.1 6.5 8.4 0.6 9.9 6.8 170 8 169 165 4.9 0 5 4.8 04/30/2006 14:00:00 7.7 0.4 8.8 6.5 7.5 0.5 8.8 6.5 8 0.5 9.1 6.5 169 10 173 165 4.9 0 5 4.8 04/30/2006 14:10:00 8.5 0.4 9.5 7.2 8.2 0.4 9.1 7.2 8.8 0.5 10.3 7.2 166 18 165 165 4.8 0.2 5.2 4.5 04/30/2006 14:20:00 9 0.5 10.3 7.6 8.7 0.5 9.9 7.2 9.3 0.5 10.7 7.6 166 9 169 165 4.5 0 4.8 4.3 04/30/2006 14:30:00 9.2 0.5 10.7 8 8.9 0.5 10.3 7.6 9.5 0.6 11.1 8 168 5 171 165 4.4 0.2 4.8 3.8 04/30/2006 14:40:00 9.2 0.4 10.7 8 8.9 0.4 10.3 7.6 9.5 0.5 10.7 7.6 166 10 169 165 3.7 0.1 4.3 3 04/30/2006 14:50:00 9.4 0.8 11.1 6.8 9.1 0.8 11.1 6.8 9.7 0.8 11.5 7.6 170 9 179 165 3.3 0.1 3.8 2.6 04/30/2006 15:00:00 9.7 0.5 10.7 7.6 9.4 0.5 10.3 7.6 10.1 0.5 11.5 8 167 5 162 165 3.3 0.1 3.5 2.6 04/30/2006 15:10:00 9.7 0.5 11.1 8 9.4 0.5 10.7 8 10 0.5 11.8 8.4 168 5 169 165 3.9 0.2 4.3 3.5 04/30/2006 15:20:00 9.4 0.5 10.7 7.6 9 0.5 10.3 8 9.7 0.6 11.1 8.4 170 9 172 165 4 0 4.3 3.5 04/30/2006 15:30:00 8.5 0.6 9.9 6.8 8.3 0.5 9.5 6.8 8.8 0.6 10.3 6.8 167 13 165 165 4.1 0.1 4.3 3.5 04/30/2006 15:40:00 9 0.5 10.3 7.6 8.8 0.5 10.3 7.6 9.3 0.5 10.7 8 170 5 177 165 4.1 0 4.3 3.8 04/30/2006 15:50:00 9.1 0.7 11.1 7.2 8.9 0.6 10.7 7.2 9.4 0.7 11.1 7.6 174 5 176 165 4 0 4.3 3.8 04/30/2006 16:00:00 10.2 0.9 12.2 8.4 9.9 0.8 11.5 8 10.4 0.9 12.2 8.4 169 6 164 165 3.5 0.3 4 2.8 04/30/2006 16:10:00 10.4 0.6 11.8 9.1 10.1 0.6 11.5 8.4 10.7 0.7 12.6 9.1 165 12 169 165 3.1 0.2 3.5 2.6 04/30/2006 16:20:00 11.8 0.8 13.7 9.5 11.5 0.7 13.3 9.1 12.1 0.8 14.1 9.1 166 14 177 165 3 0.2 3.5 2.3 04/30/2006 16:30:00 11.4 0.7 12.6 8.8 11 0.6 12.2 9.1 11.6 0.8 13.3 9.5 172 6 175 165 2.9 0.2 3.5 2.3 04/30/2006 16:40:00 11.2 0.7 13 8.8 10.8 0.6 12.2 9.1 11.4 0.8 13.3 9.5 170 5 165 165 2.7 0 2.8 2.1 04/30/2006 16:50:00 10.3 0.6 11.8 8.8 9.9 0.5 11.1 8.8 10.6 0.6 12.2 8.8 172 5 173 165 2.8 0 3 2.3 04/30/2006 17:00:00 10.2 0.6 11.8 8.8 9.9 0.6 11.8 8.4 10.5 0.7 12.6 8.8 168 5 175 165 3.2 0.3 3.8 2.6 04/30/2006 17:10:00 11.5 0.9 13.7 9.1 11.1 0.9 13.7 8.8 11.7 1.1 14.1 9.5 167 7 164 165 3.2 0.4 3.8 2.3 04/30/2006 17:20:00 12.3 0.8 14.1 9.5 11.9 0.8 13.7 9.5 12.6 0.8 14.1 10.3 166 12 163 165 2.6 0.1 3 1.8 04/30/2006 17:30:00 11.8 0.6 13 9.9 11.4 0.6 12.6 9.5 12.2 0.6 13.3 9.9 167 5 165 165 2.6 0.2 3 1.8 04/30/2006 17:40:00 11.8 0.7 13.3 9.9 11.5 0.6 13 9.5 12.1 0.9 13.7 9.5 168 8 168 165 2.5 0.1 2.8 1.8 04/30/2006 17:50:00 12 0.5 13.3 10.3 11.7 0.5 13 10.3 12.3 0.7 13.7 10.3 169 11 171 165 2.4 0.2 2.8 1.8 04/30/2006 18:00:00 11.6 0.8 13.3 8.8 11.3 0.7 13 8.8 11.8 0.9 13.7 9.1 167 10 183 165 2.3 0.2 2.6 1.8 04/30/2006 18:10:00 12.3 0.6 13.7 10.3 12 0.6 13.3 10.3 12.6 0.8 14.1 10.3 166 5 168 165 2.3 0 2.6 1.6 04/30/2006 18:20:00 11.7 0.7 13 9.5 11.3 0.6 12.6 9.1 12 0.7 13.7 10.3 168 8 166 165 2.2 0 2.3 1.6 04/30/2006 18:30:00 11.1 0.6 12.6 9.1 10.7 0.5 12.2 9.1 11.3 0.6 13 9.1 167 12 168 165 2.3 0 2.6 1.8 04/30/2006 18:40:00 11.5 0.7 13.3 9.5 11.1 0.7 12.6 9.5 11.8 0.8 13.7 9.5 172 4 179 165 2.1 0 2.6 1.8 04/30/2006 18:50:00 10.4 0.6 12.2 8.8 10.1 0.5 12.2 8.4 10.6 0.7 12.2 8 175 5 183 165 2.1 0 2.3 1.6 04/30/2006 19:00:00 9.7 0.6 11.1 7.6 9.4 0.5 10.7 8 9.9 0.6 11.5 8 174 5 181 165 2 0 2.3 1.8 04/30/2006 19:10:00 9.3 0.7 11.1 6.8 9.1 0.7 11.1 6.8 9.5 0.8 11.5 6.8 175 5 174 165 2 0 2.3 1.8 04/30/2006 19:20:00 8.8 0.5 9.9 6.8 8.5 0.5 9.5 6.8 8.9 0.6 10.3 7.2 172 5 177 165 1.9 0 2.1 1.8 04/30/2006 19:30:00 8.4 0.6 10.3 6.8 8.1 0.6 9.9 6.8 8.7 0.7 10.7 6.8 170 7 173 165 1.9 0 1.8 1.8 04/30/2006 19:40:00 9 1 11.8 6.8 8.8 1.1 11.5 6.8 9.1 1.1 13 6.5 164 14 148 165 1.8 0 1.8 1.6 04/30/2006 19:50:00 9 0.9 11.8 6.1 8.9 0.8 11.8 6.5 9.2 1 12.2 6.5 158 5 165 165 1.4 0.1 1.8 1.1 04/30/2006 20:00:00 7.6 0.6 9.1 6.1 7.4 0.6 8.8 6.1 7.7 0.6 9.1 6.1 162 3 160 165 1.2 0 1.4 1.1 04/30/2006 20:10:00 7.4 0.5 8.8 5.7 7.3 0.5 8.4 5.7 7.5 0.5 8.8 5.7 161 8 160 165 1.5 0 1.6 1.4 04/30/2006 20:20:00 9 0.7 10.7 6.8 8.8 0.7 10.3 6.8 9.4 0.7 11.1 7.2 157 5 160 165 1.7 0 1.8 1.4 04/30/2006 20:30:00 8.7 0.7 10.3 7.2 8.5 0.6 9.9 6.8 8.8 0.7 11.1 7.2 160 5 172 165 1.7 0 1.8 1.6 04/30/2006 20:40:00 8.8 0.6 10.3 7.2 8.7 0.6 10.3 7.2 8.9 0.6 10.7 7.2 159 6 160 165 1.7 0 1.8 1.6 04/30/2006 20:50:00 9.8 0.5 11.1 8 9.6 0.5 10.7 8 10 0.6 11.1 8 157 4 156 165 1.7 0 1.8 1.6 04/30/2006 21:00:00 10 0.6 12.2 8 9.8 0.6 11.8 7.6 10.2 0.6 12.2 7.6 157 4 151 165 1.7 0 1.8 1.6 04/30/2006 21:10:00 8.4 0.9 10.7 6.1 8.2 0.9 10.7 6.1 8.5 1 10.7 6.1 179 5 151 165 1.3 0.1 1.8 0.9 04/30/2006 21:20:00 7 0.5 8 5.7 6.8 0.4 8 5.7 7.1 0.5 8.4 5.3 178 5 184 165 1 0 1.1 0.9 04/30/2006 21:30:00 6 0.5 7.2 4.6 5.7 0.5 6.8 4.6 5.9 0.5 7.2 4.6 167 4 167 165 1.1 0 1.4 0.9 04/30/2006 21:40:00 5.9 0.4 6.8 4.9 5.7 0.3 6.5 4.6 5.8 0.3 6.8 4.6 163 2 164 165 0.9 0 1.1 0.9 04/30/2006 21:50:00 5.1 0.5 6.5 3.8 4.9 0.5 6.5 3.4 5 0.5 6.5 3.8 157 4 162 165 1.1 0 1.4 0.9 04/30/2006 22:00:00 7.3 1.5 9.5 4.6 7.1 1.5 9.1 4.6 7.2 1.6 10.3 3.8 161 3 164 165 1.2 0.1 1.6 0.9 04/30/2006 22:10:00 8.8 0.8 10.7 6.5 8.7 0.8 10.7 6.5 8.9 0.8 10.7 6.8 156 4 154 165 1.7 0 1.8 1.4 04/30/2006 22:20:00 9.1 0.6 11.5 7.2 9 0.6 11.1 7.2 9.2 0.7 11.5 7.6 157 4 159 165 1.8 0 1.8 1.6 04/30/2006 22:30:00 8.2 0.9 10.7 6.1 8.2 1 10.7 6.1 8.3 1 10.7 6.1 156 9 151 165 1.9 0 1.8 1.8 04/30/2006 22:40:00 7.9 0.7 9.1 5.7 7.9 0.7 9.1 5.7 8 0.7 9.5 5.7 145 5 143 165 1.9 0 1.8 1.8 04/30/2006 22:50:00 9.1 0.9 11.1 7.6 9.1 0.9 11.1 7.6 9.1 1 11.5 7.2 146 4 145 165 1.9 0 2.1 1.8 04/30/2006 23:00:00 10.8 0.8 12.6 8.4 10.7 0.8 12.6 8.4 10.9 0.9 13 8.4 151 5 139 165 2 0 2.3 1.8 04/30/2006 23:10:00 11.6 0.6 13 9.5 11.6 0.6 13.3 9.5 11.8 0.8 13.7 8.8 148 6 146 165 2 0 2.3 1.8 04/30/2006 23:20:00 11.9 0.9 13.7 9.1 11.9 1 14.1 9.1 11.8 1.1 14.1 8.8 140 6 139 165 1.8 0 1.8 1.6 04/30/2006 23:30:00 13.1 1.5 16.1 9.5 13.1 1.5 16.1 9.5 13.1 1.7 16.8 9.9 145 4 143 165 1.2 0.3 1.8 0.9 04/30/2006 23:40:00 10.1 0.7 11.8 8 10.1 0.6 12.2 8 10 0.8 11.8 7.6 141 5 131 165 1.1 0 1.4 0.9 04/30/2006 23:50:00 12.6 2.6 17.9 7.6 12.6 2.6 17.9 8.8 12.6 2.7 18.3 8.8 145 7 147 165 1.3 0 1.6 0.9 05/01/2006 00:00:00 10.4 2.9 16.8 6.5 10.2 2.9 16.4 6.5 10.5 3.1 17.2 6.8 158 6 159 165 0.7 0 0.9 0.7 05/01/2006 00:10:00 7.6 0.5 8.8 6.5 7.6 0.5 8.8 6.1 7.5 0.5 9.1 6.1 148 4 152 165 0.9 0 1.4 0.7 05/01/2006 00:20:00 7.7 1 11.5 6.1 7.7 1 11.5 6.1 7.6 1 11.8 5.7 148 5 157 165 1.2 0 1.4 0.9 05/01/2006 00:30:00 11.1 1.3 14.1 7.6 11.1 1.3 14.1 7.6 11 1.2 14.1 7.6 147 6 145 165 1.7 0.1 1.8 1.4 05/01/2006 00:40:00 13.1 1 15.6 10.7 13.1 0.9 15.3 10.3 13.1 1.1 16.1 9.9 146 4 151 165 1.5 0 1.8 1.4 05/01/2006 00:50:00 12.5 0.8 14.1 9.1 12.3 0.8 14.1 9.5 12.7 1 14.5 9.9 156 4 150 165 0.9 0.2 1.6 0.7 05/01/2006 01:00:00 10.4 0.9 13 8.4 10.4 0.9 13 8 10.3 1.1 13.3 7.6 145 7 151 165 0.9 0 1.4 0.7 05/01/2006 01:10:00 11.5 0.7 13 9.5 11.6 0.7 13 9.5 11.5 0.8 13.7 8.4 144 5 145 165 1.5 0.1 1.8 0.9 05/01/2006 01:20:00 11.5 0.7 13.3 9.5 11.5 0.7 13 9.5 11.4 0.8 13.3 8.8 141 6 139 165 1.8 0 1.8 1.6 05/01/2006 01:30:00 11.9 0.9 13.7 8.8 12 0.9 14.1 8.8 11.8 1 14.1 8.4 136 7 135 165 1.8 0 1.8 1.6 05/01/2006 01:40:00 11.3 1 13.3 8.4 11.4 1 13.7 8.8 11.1 1.1 13.3 6.8 134 6 128 165 1.8 0 1.8 1.6 05/01/2006 01:50:00 10.1 1.1 14.1 8 10.1 1.1 13.7 8 10 1.1 14.1 7.6 138 6 142 165 1.8 0 1.8 1.6 05/01/2006 02:00:00 11.8 1.5 15.3 8 11.9 1.5 16.1 8 11.6 1.5 14.9 8.4 137 7 128 165 2 0 2.1 1.8 05/01/2006 02:10:00 13.3 1 15.6 10.7 13.5 1 15.6 10.7 13 1.2 16.4 9.9 135 6 135 165 2 0 2.3 1.8 05/01/2006 02:20:00 12.8 1.3 16.4 9.9 12.9 1.2 17.2 10.3 12.6 1.4 16.1 9.5 137 6 148 165 1.9 0 2.1 1.8 05/01/2006 02:30:00 15.2 1 17.2 11.8 15.2 1 17.6 11.8 15.2 1.1 17.6 11.1 141 6 137 165 2.1 0 2.3 1.8 05/01/2006 02:40:00 16 1.3 18.7 13.3 16 1.3 18.3 13.3 16.1 1.5 19.1 13 149 5 152 165 2 0.1 2.3 1.8 05/01/2006 02:50:00 15.2 0.8 17.2 13 15 0.8 16.8 13 15.4 0.9 17.6 12.2 151 2 156 165 1.7 0 1.8 1.6 05/01/2006 03:00:00 14.1 1.2 16.8 11.5 14.1 1.2 17.2 11.1 14.2 1.2 17.2 11.5 148 4 140 165 1.8 0 2.1 1.6 05/01/2006 03:10:00 13.7 1.5 16.8 10.3 13.6 1.5 16.8 10.3 13.6 1.7 17.6 10.3 148 4 152 165 1.7 0 1.8 1.6 05/01/2006 03:20:00 12.9 0.8 16.1 11.1 12.9 0.7 16.1 11.1 12.8 0.7 15.3 11.1 142 4 136 165 1.8 0 2.1 1.6 05/01/2006 03:30:00 12.6 1.2 16.1 9.1 12.7 1.2 16.1 9.5 12.5 1.3 15.6 9.1 138 5 133 165 2 0 2.3 1.8 05/01/2006 03:40:00 14 1.7 17.6 9.9 14.2 1.8 17.9 9.9 13.9 1.9 17.6 7.6 134 7 143 165 2.2 0 2.3 2.1 05/01/2006 03:50:00 15 1.3 18.3 11.8 15.1 1.3 18.7 11.8 14.8 1.3 17.9 11.1 135 5 135 165 2.2 0 2.3 2.1 05/01/2006 04:00:00 14.1 1.3 17.6 10.7 14.2 1.3 17.6 10.7 13.9 1.4 17.6 10.7 134 7 148 165 2.3 0 2.3 2.1 05/01/2006 04:10:00 14.1 1.2 16.8 10.3 14.3 1.2 17.2 10.3 14 1.4 17.2 9.5 131 6 144 165 2.3 0 2.6 2.1 05/01/2006 04:20:00 14 1.2 17.2 11.1 14.2 1.2 17.6 11.5 13.8 1.2 17.2 11.1 125 5 121 165 2.3 0 2.6 2.3 05/01/2006 04:30:00 13.4 1.2 16.8 9.9 13.6 1.3 17.2 9.5 13.2 1.2 16.4 10.3 123 5 119 165 2.3 0 2.6 2.1 05/01/2006 04:40:00 14.3 1.4 17.6 10.7 14.5 1.4 17.9 11.1 14.2 1.5 19.1 9.9 127 5 120 165 2.1 0 2.3 2.1 05/01/2006 04:50:00 14.5 1.7 17.9 10.3 14.6 1.7 17.9 10.3 14.1 1.8 18.7 9.9 131 8 147 165 2.2 0 2.3 2.1 05/01/2006 05:00:00 13.9 1.5 17.9 9.9 14.1 1.5 17.6 10.3 13.6 1.6 17.6 8.8 126 7 135 165 2.3 0 2.6 2.3 05/01/2006 05:10:00 15.4 1.4 19.1 12.2 15.6 1.4 19.1 12.2 15.2 1.5 19.5 11.1 127 7 135 165 2.4 0 2.6 2.3 05/01/2006 05:20:00 14 1.8 18.3 9.9 14.3 1.8 19.1 9.9 13.7 1.8 18.3 9.9 124 6 133 165 2.3 0 2.6 2.3 05/01/2006 05:30:00 14.1 1.5 17.2 9.9 14.4 1.5 17.9 9.9 13.7 1.5 17.2 9.1 121 7 122 165 2.4 0 2.6 2.3 05/01/2006 05:40:00 14.7 1.6 18.7 10.7 15 1.6 18.3 10.7 14.3 1.7 17.9 9.1 120 6 127 165 2.3 0 2.6 2.3 05/01/2006 05:50:00 17.8 2.2 22.6 13.3 18 2.2 22.9 13 17.4 2.5 22.9 11.1 127 8 123 165 1.7 0.4 2.6 0.9 05/01/2006 06:00:00 14.7 2 18.7 8.8 14.9 2 19.1 9.1 14.2 2 18.7 9.1 121 5 121 165 1.5 0.1 1.8 0.9 05/01/2006 06:10:00 13.6 1.7 17.6 9.1 13.8 1.8 17.9 9.5 13 1.9 17.9 6.8 119 5 113 165 2 0 2.3 1.6 05/01/2006 06:20:00 12.9 2 17.6 8 13.1 2.1 17.9 8 12.4 2.1 16.8 7.2 118 10 105 165 2.3 0 2.6 2.1 05/01/2006 06:30:00 14.9 1.5 17.9 10.3 15.2 1.5 18.3 10.7 14.2 1.6 17.9 10.3 114 6 109 165 2.3 0 2.6 2.3 05/01/2006 06:40:00 13.3 1.5 17.6 9.1 13.6 1.6 17.6 8.8 12.5 1.8 17.2 8.4 112 7 111 165 2.3 0 2.6 2.3 05/01/2006 06:50:00 14.9 1.4 18.7 11.5 15.2 1.4 19.5 11.8 14.4 1.5 19.1 11.1 110 6 117 165 2.3 0 2.6 2.1 05/01/2006 07:00:00 15.2 2.9 20.2 8.4 15.4 2.9 21 8.4 14.4 2.9 19.9 8.4 111 7 109 165 2.4 0 2.6 2.3 05/01/2006 07:10:00 16.3 2 21 10.7 16.7 2 21.8 11.5 15.6 2.1 21 10.3 114 7 111 165 2.4 0 2.6 2.3 05/01/2006 07:20:00 16.9 1.7 21 12.2 17.2 1.8 21.4 12.6 15.9 1.8 21 11.1 112 6 110 165 2.1 0 2.3 1.8 05/01/2006 07:30:00 15.7 1.8 19.9 10.7 15.9 1.8 20.2 11.1 15.2 1.9 19.1 10.7 118 7 128 165 2.4 0 2.6 2.1 05/01/2006 07:40:00 16.3 2.7 21.4 8.8 16.6 2.8 21.4 9.5 15.6 2.8 21 8.4 118 6 112 165 2.6 0 2.8 2.6 05/01/2006 07:50:00 16.8 1.9 21.4 10.7 17.1 1.9 22.1 11.5 15.7 2.1 21.4 10.7 111 6 108 165 2.4 0 2.8 2.3 05/01/2006 08:00:00 16.3 1.8 20.6 11.5 16.6 1.8 21 11.1 15.8 1.9 21 11.1 118 7 106 165 2.5 0 2.8 2.3 05/01/2006 08:10:00 14.9 2.2 20.2 8 15.2 2.2 20.6 8.8 14.1 2.4 20.2 7.6 118 9 123 165 2.5 0 2.6 2.6 05/01/2006 08:20:00 16.8 2.8 22.9 9.5 17 2.9 23.7 10.3 15.9 2.9 22.9 9.5 111 8 115 165 2.5 0 2.6 2.3 05/01/2006 08:30:00 15.7 2 21.4 10.3 15.9 2.1 21.8 10.3 15 2.2 22.1 9.1 117 6 115 165 2.2 0 2.6 2.1 05/01/2006 08:40:00 16.5 2.1 21.4 11.1 16.7 2.2 21.8 10.7 15.8 2.1 20.6 10.3 115 6 106 165 2.2 0 2.3 2.1 05/01/2006 08:50:00 16.4 2.3 21 9.5 16.6 2.3 21.4 9.1 15.8 2.5 21 9.1 116 9 105 165 2.1 0.1 2.3 1.8 05/01/2006 09:00:00 17.3 2.6 23.3 11.8 17.6 2.6 24 11.8 16.5 2.8 23.3 10.7 113 7 108 165 2 0 2.3 1.8 05/01/2006 09:10:00 16.6 2.4 24 9.9 16.9 2.5 22.9 9.9 15.7 2.3 21.4 10.3 113 7 107 165 2.1 0.1 2.3 1.8 05/01/2006 09:20:00 18.9 1.7 22.9 13 19.2 1.8 23.3 13 18.4 1.9 22.6 12.6 109 6 105 165 1.8 0 1.8 1.6 05/01/2006 09:30:00 17.2 2.3 22.1 10.7 17.4 2.3 22.9 11.5 16.5 2.5 22.1 9.9 111 7 106 165 1.7 0 1.8 1.6 05/01/2006 09:40:00 16.6 2.1 22.1 11.1 16.8 2.2 22.1 11.5 15.5 2.2 21 9.5 108 7 107 165 1.8 0 1.8 1.6 05/01/2006 09:50:00 18.5 2.2 22.9 12.2 18.7 2.3 23.3 11.8 17.3 2.2 23.3 9.9 108 6 106 165 1.8 0 1.8 1.6 05/01/2006 10:00:00 17.3 2.2 21.8 11.5 17.7 2.2 22.1 11.5 16.4 2.3 21.4 10.7 110 6 116 165 1.7 0 1.8 1.6 05/01/2006 10:10:00 16.1 2.6 22.6 10.3 16.5 2.6 23.3 9.5 15.2 2.7 22.6 9.1 107 8 106 165 1.7 0 1.8 1.6 05/01/2006 10:20:00 18 2.3 22.9 12.6 18.4 2.3 23.7 13 16.9 2.2 21.4 11.1 104 5 105 165 1.8 0 1.8 1.6 05/01/2006 10:30:00 17.4 2.2 22.6 11.8 17.8 2.3 22.9 11.8 16.4 2.2 21.8 10.3 106 6 102 165 1.8 0 1.8 1.6 05/01/2006 10:40:00 15.7 3.2 22.1 8.4 16 3.2 22.1 8 14.6 3.3 21.4 8 108 8 107 165 1.8 0 2.1 1.8 05/01/2006 10:50:00 16.9 2.3 22.1 9.5 17.1 2.4 22.6 9.1 15.8 2.5 22.6 10.3 104 8 110 165 1.8 0 1.8 1.6 05/01/2006 11:00:00 17.3 2.4 21 10.3 17.6 2.5 21.4 9.9 16.5 2.6 21 8.4 100 7 102 165 1.8 0 1.8 1.6 05/01/2006 11:10:00 16 2.3 22.6 9.9 16.2 2.4 23.7 10.3 15.2 2.3 21.4 9.1 106 7 102 165 1.7 0 1.8 1.6 05/01/2006 11:20:00 16.3 2.2 21.8 10.3 16.7 2.3 22.9 9.9 15.1 2.3 20.2 8.8 100 8 102 165 1.7 0 1.8 1.6 05/01/2006 11:30:00 16.7 2.3 21.4 10.3 17 2.3 21.8 10.7 15.9 2.3 20.6 10.7 94 6 87 165 1.7 0 1.8 1.6 05/01/2006 11:40:00 15.2 2.6 22.9 9.1 15.5 2.6 22.1 9.9 14.5 2.6 21.8 8.4 93 8 102 165 1.7 0 1.8 1.6 05/01/2006 11:50:00 16.1 2.4 20.6 9.1 16.6 2.5 21.4 9.5 15.3 2.6 20.2 8 94 7 92 165 1.8 0 1.8 1.6 05/01/2006 12:00:00 15 1.9 19.5 9.5 15.5 2 19.5 9.5 14.2 1.9 18.7 9.1 94 8 99 165 1.8 0 1.8 1.6 05/01/2006 12:10:00 15.7 2 20.2 11.1 15.9 2 20.6 11.1 14.9 2 20.2 9.9 89 7 98 165 1.8 0 1.8 1.6 05/01/2006 12:20:00 15.7 1.7 19.5 11.5 16 1.7 19.9 10.7 14.9 1.8 19.1 9.9 90 8 101 165 1.8 0 1.8 1.6 05/01/2006 12:30:00 15 1.9 19.5 9.5 15.3 2 19.9 9.1 14.2 1.9 19.1 9.9 87 7 98 165 1.8 0 1.8 1.6 05/01/2006 12:40:00 14.8 1.8 20.6 10.7 15 1.9 20.6 10.7 14 1.8 20.2 9.9 85 8 86 165 1.8 0 1.8 1.6 05/01/2006 12:50:00 16.2 2.3 21.8 10.7 16.5 2.4 22.1 11.1 15.5 2.2 20.6 9.5 85 8 85 165 1.8 0 1.8 1.6 05/01/2006 13:00:00 15.7 2.3 21.4 11.5 16 2.4 21.8 11.5 15.1 2.3 21.8 10.3 86 8 84 165 1.8 0 1.8 1.6 05/01/2006 13:10:00 15.5 1.9 21.4 11.1 15.8 1.9 21 10.7 14.9 2 20.2 9.5 88 8 96 165 1.8 0 1.8 1.6 05/01/2006 13:20:00 15.8 2.7 22.1 9.1 16.2 2.8 21.8 9.5 15.4 2.7 21.4 9.1 85 7 85 165 1.8 0 1.8 1.8 05/01/2006 13:30:00 15.1 2.2 20.6 10.3 15.3 2.2 20.6 10.3 14.5 2.1 19.9 9.1 85 8 98 165 1.9 0 1.8 1.8 05/01/2006 13:40:00 15.9 1.8 21 11.5 16.2 1.9 21.8 11.5 15 1.9 20.2 10.7 85 7 91 165 1.9 0 1.8 1.8 05/01/2006 13:50:00 16.4 2 21.4 10.7 16.8 2.1 21.8 11.5 15.7 2 20.6 10.7 86 7 98 165 1.9 0 2.1 1.8 05/01/2006 14:00:00 15.5 2.1 19.9 10.3 15.9 2.1 19.9 11.1 14.6 2.1 19.9 9.5 88 9 102 165 1.9 0 2.1 1.8 05/01/2006 14:10:00 16 2.6 21 8.8 16.3 2.6 21.4 8.8 15.2 2.6 20.6 8.4 90 8 88 165 1.9 0 2.1 1.8 05/01/2006 14:20:00 15.7 2.4 21 9.1 16.1 2.4 21.4 9.1 15 2.4 20.2 9.9 88 7 95 165 1.9 0 2.1 1.8 05/01/2006 14:30:00 15 2 20.2 9.9 15.3 2.1 21 10.7 14.3 2.2 18.7 9.5 88 8 87 165 1.9 0 2.1 1.8 05/01/2006 14:40:00 16 2.2 21.4 10.7 16.2 2.2 21.4 11.1 15.2 2.1 19.9 9.5 89 8 96 165 1.9 0 2.1 1.8 05/01/2006 14:50:00 16.7 2.2 22.1 11.1 17 2.2 22.9 11.5 15.7 2.2 21.4 10.3 89 8 80 165 1.9 0 1.8 1.8 05/01/2006 15:00:00 15.7 2.6 23.3 9.9 16.1 2.6 23.7 9.9 15.2 2.5 21.4 9.9 92 8 101 165 1.9 0 1.8 1.8 05/01/2006 15:10:00 15.6 2.1 20.6 10.7 16.2 2.2 21.8 11.1 14.9 2 20.6 10.3 90 8 85 165 1.9 0 1.8 1.8 05/01/2006 15:20:00 15.6 2.3 21 10.7 16.1 2.4 21.4 10.3 14.8 2.3 21.4 9.9 87 7 78 165 1.9 0 1.8 1.8 05/01/2006 15:30:00 15.2 2.1 19.9 10.3 15.8 2.2 20.6 10.7 14.6 2.1 19.5 9.1 90 7 84 165 1.9 0 2.1 1.6 05/01/2006 15:40:00 14.4 1.9 19.9 9.5 15 2 20.6 10.3 13.9 2 19.5 8.8 88 7 88 165 1.9 0 1.8 1.8 05/01/2006 15:50:00 14.9 1.7 18.7 9.9 15.3 1.7 19.1 10.7 14.2 1.8 17.9 9.5 91 7 91 165 1.9 0 1.8 1.8 05/01/2006 16:00:00 14.4 1.8 18.7 8.8 15 1.9 19.5 9.5 13.7 1.7 18.3 9.1 90 7 84 165 1.8 0 1.8 1.8 05/01/2006 16:10:00 13.9 1.9 18.3 9.1 14.3 1.9 19.1 9.1 13 1.7 16.8 8.8 91 8 88 165 1.8 0 1.8 1.8 05/01/2006 16:20:00 13.7 1.9 17.6 8.8 14.3 2 18.7 9.1 13 2 17.6 8 90 7 85 165 1.8 0 1.8 1.6 05/01/2006 16:30:00 13.9 1.5 16.8 9.9 14.4 1.5 17.6 9.9 13.3 1.6 17.2 9.5 88 6 87 165 1.8 0 1.8 1.6 05/01/2006 16:40:00 13.7 1.5 16.8 8.4 14.2 1.6 17.6 9.1 13.1 1.5 16.1 8.8 92 6 90 165 1.8 0 1.8 1.6 05/01/2006 16:50:00 13.2 1.7 16.4 8 13.7 1.7 16.8 8.8 12.1 1.7 16.1 7.6 96 6 99 165 1.8 0 1.8 1.6 05/01/2006 17:00:00 13.9 1.3 16.4 9.9 14.2 1.4 16.8 9.9 12.9 1.5 15.6 9.1 95 7 93 165 1.8 0 1.8 1.6 05/01/2006 17:10:00 14 1.5 17.9 9.9 14.3 1.5 18.7 9.9 13 1.5 16.4 8.8 97 6 99 165 1.8 0 2.1 1.6 05/01/2006 17:20:00 12.8 1.7 18.7 8.4 13.2 1.8 19.5 9.1 12 1.8 18.3 8.4 102 7 102 165 2.1 0 2.3 1.8 05/01/2006 17:30:00 13.6 1.6 17.6 9.1 14 1.6 17.9 9.5 13 1.7 17.2 8.8 102 6 104 165 2.2 0 2.3 1.8 05/01/2006 17:40:00 12.3 1.9 15.6 7.2 12.6 2 16.1 7.6 11.5 1.9 15.3 6.8 101 6 88 165 2.3 0 2.3 2.1 05/01/2006 17:50:00 12.8 1.4 15.6 9.1 13.1 1.3 15.6 9.5 12.1 1.5 15.3 8.8 102 6 103 165 2.4 0 2.6 2.1 05/01/2006 18:00:00 13.1 1.2 16.8 9.1 13.5 1.2 17.6 9.9 12.2 1.5 16.4 8.4 102 7 95 165 2.7 0 3 2.6 05/01/2006 18:10:00 13.4 1.3 17.2 9.5 13.6 1.3 16.8 9.9 12.7 1.3 16.1 9.1 106 6 113 165 3 0.1 3.3 2.8 05/01/2006 18:20:00 13.3 1.1 16.1 8.8 13.5 1.1 16.4 9.5 12.7 1.3 16.1 9.1 110 6 111 165 3.2 0 3.5 3 05/01/2006 18:30:00 11.8 1.6 15.3 7.2 12 1.6 15.3 7.2 11.2 1.5 14.9 6.5 109 6 102 165 3.3 0 3.5 3.3 05/01/2006 18:40:00 11.8 1.2 14.9 9.1 11.9 1.2 15.3 9.1 11.4 1.2 14.5 8 118 5 112 165 3.5 0 3.5 3.3 05/01/2006 18:50:00 9.9 0.8 12.2 7.6 10 0.8 12.6 8 9.7 1 13 6.8 123 6 114 165 3.5 0 3.5 3.3 05/01/2006 19:00:00 9.4 0.8 11.5 7.2 9.5 0.8 11.5 7.2 9.2 0.8 11.5 6.8 125 5 139 165 3.5 0 3.5 3.5 05/01/2006 19:10:00 9 1 11.5 6.5 9.1 1 12.2 6.5 8.8 0.9 11.5 6.8 127 6 122 165 3.5 0 3.5 3.5 05/01/2006 19:20:00 9.5 0.7 11.1 7.2 9.5 0.7 11.5 7.2 9.4 0.8 11.5 6.8 128 6 132 165 3.5 0 3.5 3.3 05/01/2006 19:30:00 8.7 0.8 10.7 6.8 8.7 0.8 10.7 6.8 8.3 0.8 10.3 6.1 133 6 131 165 3.5 0 3.5 3.3 05/01/2006 19:40:00 8 1 9.9 5.3 8 1 9.9 5.3 7.9 1 10.3 5.7 135 6 133 165 3.5 0 3.8 3.5 05/01/2006 19:50:00 6.9 0.5 8 5.3 6.9 0.5 8 5.3 6.9 0.6 8.4 5.3 134 6 129 165 3.5 0 3.8 3.5 05/01/2006 20:00:00 7.3 0.5 8.4 5.7 7.2 0.5 8.4 5.7 7.1 0.6 8.4 5.7 142 6 147 165 3.5 0 3.5 3.5 05/01/2006 20:10:00 7.3 0.5 8.8 5.7 7.2 0.5 8.4 6.1 7.3 0.5 8.8 6.1 147 3 145 165 3.5 0 3.5 3.5 05/01/2006 20:20:00 7.1 0.5 8.4 5.7 7 0.5 8.4 5.7 7 0.5 8.4 5.3 144 3 147 165 3.5 0 3.5 3.3 05/01/2006 20:30:00 6.8 0.3 7.6 6.1 6.7 0.3 7.2 6.1 6.9 0.3 7.6 6.1 148 3 145 165 3.6 0 3.5 3.5 05/01/2006 20:40:00 6.5 0.4 7.6 5.7 6.4 0.4 7.6 5.7 6.7 0.4 7.6 5.7 149 3 151 165 3.6 0 3.5 3.3 05/01/2006 20:50:00 6.3 0.7 7.6 4.9 6.2 0.7 7.6 4.6 6.5 0.6 7.6 5.3 152 3 153 165 3.6 0 3.8 3.5 05/01/2006 21:00:00 5.5 0.3 6.1 4.9 5.3 0.3 6.1 4.6 5.8 0.3 6.5 4.9 158 2 157 165 3.6 0 3.8 3.5 05/01/2006 21:10:00 4.7 0.3 5.3 4.2 4.5 0.3 5.3 3.8 5 0.3 5.7 4.2 159 3 161 165 3.6 0 3.8 3.5 05/01/2006 21:20:00 4.5 0.2 4.9 3.8 4.4 0.2 4.9 3.8 4.8 0.2 5.3 4.2 152 3 157 165 3.6 0 3.8 3.5 05/01/2006 21:30:00 4.7 0.2 5.3 4.2 4.6 0.2 4.9 3.8 4.9 0.2 5.7 4.2 154 3 152 165 3.5 0 3.5 3.3 05/01/2006 21:40:00 4.6 0.3 5.3 3.8 4.5 0.3 4.9 3.8 4.8 0.3 5.3 4.2 151 5 152 165 3.4 0 3.5 3.3 05/01/2006 21:50:00 3.6 0.6 4.9 2.3 3.5 0.6 4.9 2.3 3.9 0.6 5.3 2.6 152 7 143 165 3.3 0 3.5 3.3 05/01/2006 22:00:00 4.1 0.8 5.7 2.6 4 0.8 5.7 2.6 4.2 0.7 5.3 2.6 143 6 135 165 3.3 0 3.5 3 05/01/2006 22:10:00 4.8 0.4 5.7 3.8 4.8 0.5 5.7 3.4 4.9 0.5 6.1 3.8 144 5 136 165 3.3 0 3.5 3.3 05/01/2006 22:20:00 5.5 0.5 6.5 4.2 5.4 0.4 6.5 4.2 5.7 0.4 6.5 4.6 154 3 158 165 3.3 0 3.5 3.3 05/01/2006 22:30:00 5.4 0.4 6.8 4.6 5.3 0.4 6.5 4.6 5.5 0.4 6.5 4.6 155 5 157 165 3.3 0 3.5 3.3 05/01/2006 22:40:00 5.6 0.5 7.2 4.2 5.4 0.5 6.8 4.2 5.8 0.5 6.8 4.6 160 7 163 165 3.1 0.1 3.5 2.8 05/01/2006 22:50:00 5.2 0.6 7.2 3.8 5.2 0.6 7.2 3.8 5.4 0.6 7.2 4.2 162 6 162 165 2.8 0 3 2.6 05/01/2006 23:00:00 5.5 0.6 6.8 4.2 5.4 0.6 6.8 4.2 5.6 0.7 7.2 4.6 170 7 176 165 2.7 0 2.8 2.6 05/01/2006 23:10:00 4.1 0.9 6.5 2.3 4 0.8 6.1 2.6 4.1 1 6.8 2.6 168 8 173 165 2.5 0.1 2.8 2.3 05/01/2006 23:20:00 4.3 0.6 5.7 3 4.3 0.5 5.7 3 4.2 0.5 5.7 3 153 5 157 165 2.6 0 2.8 2.3 05/01/2006 23:30:00 3.6 0.3 4.6 2.6 3.5 0.3 4.2 2.6 3.5 0.3 4.2 2.6 156 5 156 165 2.6 0 2.8 2.6 05/01/2006 23:40:00 3.9 0.2 4.6 3.4 3.8 0.2 4.2 3.4 3.9 0.3 4.6 3.4 150 2 150 165 2.7 0 3 2.6 05/01/2006 23:50:00 4.1 0.5 5.7 2.6 4 0.5 5.3 2.3 4.1 0.4 5.7 3 153 5 151 165 2.9 0 3 2.8 05/02/2006 00:00:00 4.3 0.8 6.8 2.6 4.2 0.7 6.1 2.3 4.3 0.7 6.5 2.6 142 10 164 165 2.9 0 3 2.8 05/02/2006 00:10:00 5.5 0.7 6.8 4.2 5.5 0.7 7.2 3.8 5.5 0.7 7.2 3.8 142 7 143 165 2.9 0 3 2.8 05/02/2006 00:20:00 5.3 0.6 6.8 4.2 5.3 0.6 6.8 4.2 5.4 0.6 8 3.8 143 9 123 165 2.9 0 3.3 2.8 05/02/2006 00:30:00 5.3 0.8 7.6 3.4 5.2 0.8 7.2 3 5.3 0.8 7.6 3.4 145 10 160 165 3 0 3.3 3 05/02/2006 00:40:00 5 0.7 6.8 3 4.9 0.7 6.5 3 5 0.7 7.2 3.4 141 10 134 165 3.1 0 3.3 3 05/02/2006 00:50:00 5.7 0.7 7.2 3.4 5.7 0.7 7.2 3.4 5.7 0.8 7.2 3.4 138 8 131 165 3.2 0 3.5 3 05/02/2006 01:00:00 9.2 2.1 14.5 4.9 9.1 2.1 14.5 5.3 8.9 2.3 14.5 4.6 143 8 154 165 3.2 0.1 3.5 2.6 05/02/2006 01:10:00 7.7 2.3 12.6 4.9 7.6 2.2 12.6 4.9 7.8 2.4 13 4.6 149 7 151 165 2.2 0.1 2.6 1.8 05/02/2006 01:20:00 4.2 0.8 5.7 2.6 4 0.8 6.1 2.6 4.2 0.6 5.7 3 146 5 134 165 2 0 2.1 1.8 05/02/2006 01:30:00 3.9 0.4 4.9 3 3.9 0.5 4.9 3 4.1 0.5 5.3 3 140 6 137 165 2 0 2.3 1.8 05/02/2006 01:40:00 5.2 0.4 6.1 4.2 5.2 0.4 6.1 4.2 5.3 0.4 6.5 4.2 136 8 145 165 2.3 0 2.6 1.8 05/02/2006 01:50:00 5 0.6 6.5 3.8 5 0.5 6.8 3.8 5.1 0.5 6.5 3.8 134 8 116 165 2.4 0 2.6 2.1 05/02/2006 02:00:00 6.2 0.7 8 4.2 6.2 0.7 7.6 4.2 6.3 0.6 8 4.9 135 5 130 165 2.4 0 2.6 2.3 05/02/2006 02:10:00 5.6 0.6 7.2 4.2 5.5 0.6 7.2 4.2 5.6 0.6 7.2 4.2 143 5 146 165 2.5 0 2.8 2.3 05/02/2006 02:20:00 6.4 0.6 8 4.9 6.3 0.6 8 4.6 6.4 0.6 8 4.9 141 6 137 165 2.6 0 2.8 2.6 05/02/2006 02:30:00 8.8 1.2 10.7 6.1 8.7 1.1 10.7 6.1 8.7 1.2 11.1 6.1 147 7 150 165 2.5 0 2.8 2.3 05/02/2006 02:40:00 8.6 0.8 10.3 6.8 8.4 0.8 10.3 6.8 8.7 0.9 10.7 6.5 155 3 154 165 2.4 0 2.6 2.3 05/02/2006 02:50:00 7.5 0.4 8.8 6.8 7.5 0.4 8.8 6.8 7.6 0.4 8.8 6.5 149 3 150 165 2.4 0 2.6 2.3 05/02/2006 03:00:00 7 0.4 8 6.1 7 0.4 8 6.1 7.1 0.4 8 6.1 151 3 153 165 2.3 0 2.6 2.1 05/02/2006 03:10:00 5.6 0.4 6.8 4.6 5.5 0.4 6.8 4.2 5.7 0.5 6.8 4.2 152 4 150 165 2.2 0 2.3 2.1 05/02/2006 03:20:00 5.6 0.4 6.5 4.6 5.5 0.4 6.5 4.6 5.7 0.4 6.5 4.6 150 4 150 165 2.3 0 2.6 2.3 05/02/2006 03:30:00 6.4 0.7 8 4.9 6.4 0.7 8 4.9 6.6 0.7 8.4 5.3 149 5 145 165 2.4 0 2.6 2.3 05/02/2006 03:40:00 7.4 0.6 9.1 5.7 7.4 0.6 8.8 5.7 7.4 0.6 8.8 5.7 147 5 157 165 2.3 0 2.6 2.3 05/02/2006 03:50:00 9.1 1 11.5 6.8 9 1 11.8 6.8 9 1 11.8 6.5 143 5 143 165 2.4 0 2.6 2.3 05/02/2006 04:00:00 10.3 1.2 13 7.6 10.2 1.2 13 7.6 10.3 1.2 13 7.6 147 5 147 165 2.4 0 2.6 2.3 05/02/2006 04:10:00 8.8 0.8 10.7 6.5 8.8 0.8 10.3 6.5 8.7 0.8 10.7 6.1 144 6 151 165 2.3 0 2.3 2.3 05/02/2006 04:20:00 10.7 1 12.6 7.6 10.7 1 12.6 7.6 10.5 1 12.2 7.6 148 4 156 165 2.3 0 2.6 2.1 05/02/2006 04:30:00 8 0.8 9.9 6.1 8 0.8 9.9 6.1 7.7 0.9 9.9 5.7 146 5 150 165 2.3 0 2.6 2.1 05/02/2006 04:40:00 7.2 0.8 9.9 5.3 7.1 0.8 9.9 5.3 7 0.7 9.9 4.9 149 5 160 165 2.4 0 2.6 2.3 05/02/2006 04:50:00 11 0.8 13.3 9.1 11 0.9 13 9.1 11 0.9 13 8.8 151 6 150 165 2.4 0 2.6 2.3 05/02/2006 05:00:00 9.9 0.7 11.8 8 9.9 0.7 12.2 8.4 9.9 0.8 11.8 7.6 147 5 148 165 2.7 0 3 2.3 05/02/2006 05:10:00 8.7 0.7 10.3 7.2 8.6 0.7 10.3 7.2 8.7 0.8 10.3 6.8 149 3 145 165 2.7 0 2.8 2.6 05/02/2006 05:20:00 7.5 0.6 9.1 5.7 7.4 0.6 9.1 5.7 7.4 0.7 9.1 5.7 146 4 148 165 2.7 0 2.8 2.3 05/02/2006 05:30:00 8.5 0.7 10.7 6.8 8.5 0.8 10.7 6.8 8.3 0.8 10.7 6.8 144 4 144 165 2.8 0 3 2.6 05/02/2006 05:40:00 8.2 0.6 9.9 6.5 8.2 0.6 9.9 6.5 8.1 0.7 10.3 6.1 140 7 137 165 2.9 0 3 2.8 05/02/2006 05:50:00 7.9 0.7 10.3 6.1 7.9 0.7 9.5 6.1 8 0.7 9.9 5.7 139 7 145 165 3 0 3 2.8 05/02/2006 06:00:00 11 1.8 13.7 6.5 11.1 1.9 13.7 6.5 10.7 2 13.7 5.7 138 6 147 165 2.8 0.2 3.3 2.6 05/02/2006 06:10:00 12.1 1 14.9 9.5 12.1 1 14.5 9.1 12.1 1.1 14.5 8.4 140 6 139 165 2.5 0 2.8 2.6 05/02/2006 06:20:00 10.6 1 13.3 8 10.7 1 13.3 8.4 10.3 1 12.6 7.6 137 6 150 165 2.4 0 2.6 2.3 05/02/2006 06:30:00 10 1 12.2 7.6 10 1 12.6 7.6 9.8 1 12.2 6.8 132 8 143 165 2.4 0 2.6 2.3 05/02/2006 06:40:00 9.1 0.8 11.8 6.8 9.2 0.8 11.5 7.2 9.1 0.8 11.5 6.8 132 6 126 165 2.4 0 2.6 2.3 05/02/2006 06:50:00 9.1 0.7 11.1 7.6 9.2 0.7 11.1 7.6 8.9 0.8 11.1 6.8 130 7 134 165 2.6 0 2.8 2.3 05/02/2006 07:00:00 9.3 0.9 11.1 6.5 9.3 0.9 11.1 6.5 9.2 1 11.5 5.7 130 6 133 165 2.7 0 2.8 2.6 05/02/2006 07:10:00 9.1 0.8 11.5 6.5 9.1 0.8 11.5 6.5 8.9 0.8 10.7 6.1 131 6 133 165 2.8 0 2.8 2.8 05/02/2006 07:20:00 9.3 1 11.5 6.8 9.4 1 11.5 6.8 9.1 1 11.8 6.8 129 8 124 165 2.7 0 2.8 2.6 05/02/2006 07:30:00 10 0.7 11.8 8.4 10 0.8 12.2 8.4 9.7 0.8 11.8 7.6 134 6 129 165 2.9 0 3 2.6 05/02/2006 07:40:00 11.5 1.8 15.3 8 11.6 1.8 15.3 8 11.4 2 15.6 7.2 141 6 132 165 3 0 3.3 2.8 05/02/2006 07:50:00 11.7 0.8 13.7 9.1 11.7 0.9 13.7 9.1 11.7 0.8 13.7 9.5 143 5 135 165 3 0 3.3 2.8 05/02/2006 08:00:00 10.9 0.9 13.3 8 10.8 1 13 7.6 11 1 13.7 8 154 6 139 165 3 0 3.3 3 05/02/2006 08:10:00 10.6 0.6 11.8 9.1 10.6 0.6 11.8 9.1 10.6 0.8 12.2 8.4 148 3 147 165 3.1 0 3.3 3 05/02/2006 08:20:00 10.1 0.9 12.6 7.2 10.2 1 13 6.8 9.8 1.2 13 6.5 136 7 131 165 3.3 0 3.5 2.8 05/02/2006 08:30:00 12.5 0.8 14.5 9.9 12.6 0.8 14.5 9.9 12.3 1 14.5 8.8 139 5 136 165 3.2 0 3.5 3.3 05/02/2006 08:40:00 11.1 0.8 13.3 9.1 11 0.8 13.7 9.1 11.1 0.8 13.3 8.8 148 5 142 165 3.1 0.1 3.5 3 05/02/2006 08:50:00 10.7 0.8 12.6 8.4 10.6 0.8 12.6 8.4 10.5 0.9 12.6 7.6 141 6 136 165 3.2 0 3.3 3 05/02/2006 09:00:00 10.8 1 13.3 8 10.8 1 13 7.6 10.7 1 13.7 8 139 6 142 165 3 0 3.3 2.8 05/02/2006 09:10:00 10.1 0.8 12.2 7.6 10.2 0.8 11.8 7.6 9.8 1 12.2 7.6 136 5 140 165 2.9 0 3.3 2.8 05/02/2006 09:20:00 9.6 1 11.8 6.5 9.6 1 11.8 6.8 9.4 1.2 11.8 5.7 139 7 132 165 3.3 0 3.5 3 05/02/2006 09:30:00 9.6 0.8 11.8 7.2 9.6 0.8 11.8 7.2 9.5 0.8 12.2 7.2 144 5 143 165 3.4 0 3.5 3.3 05/02/2006 09:40:00 9.1 0.6 10.3 7.6 9.1 0.6 10.3 7.6 9.2 0.6 11.1 7.6 144 5 147 165 3.3 0 3.5 3.3 05/02/2006 09:50:00 9 0.6 11.1 7.2 9 0.7 10.7 7.2 8.8 0.7 10.7 6.5 138 5 145 165 3.3 0 3.5 3.3 05/02/2006 10:00:00 10.2 0.9 12.6 7.6 10.2 0.9 12.2 7.6 10.3 1 12.6 6.5 140 5 136 165 3.3 0 3.5 3.3 05/02/2006 10:10:00 10.6 0.7 12.2 8.8 10.5 0.7 12.2 8.8 10.4 0.8 12.6 7.6 141 4 139 165 2.9 0 3.3 2.8 05/02/2006 10:20:00 9.6 0.6 11.1 7.6 9.6 0.7 11.5 7.6 9.4 0.8 11.5 6.8 139 5 134 165 3.3 0 3.5 3 05/02/2006 10:30:00 9.2 0.6 10.7 7.6 9.3 0.6 10.7 7.2 9.2 0.7 10.7 7.2 140 6 136 165 3.5 0 3.8 3.5 05/02/2006 10:40:00 9.4 0.6 10.7 7.2 9.4 0.6 10.3 6.8 9.4 0.7 11.5 7.2 142 6 148 165 3.5 0 3.8 3.3 05/02/2006 10:50:00 9.3 0.6 10.3 7.6 9.2 0.6 10.3 7.2 9.4 0.7 10.7 6.8 149 3 150 165 3.3 0 3.5 3.3 05/02/2006 11:00:00 7.6 0.5 8.8 6.1 7.5 0.5 8.4 6.1 7.5 0.6 8.8 4.9 148 7 145 165 3.5 0 3.5 3.3 05/02/2006 11:10:00 7.6 0.7 9.5 5.3 7.6 0.7 9.1 5.7 7.7 0.7 9.5 4.6 143 6 142 165 3.6 0.1 3.8 3.3 05/02/2006 11:20:00 8.8 0.7 10.3 7.2 8.8 0.7 10.7 7.2 8.9 0.7 10.7 7.2 144 6 142 165 3.4 0 3.5 2.8 05/02/2006 11:30:00 9.8 0.4 10.7 8.4 9.8 0.4 10.7 8.8 10 0.5 11.1 8.8 146 4 149 165 3.3 0 3.5 2.8 05/02/2006 11:40:00 10 0.6 11.5 8.4 10 0.6 11.5 8 10.2 0.6 11.5 8.4 145 4 145 165 3.2 0 3.5 2.8 05/02/2006 11:50:00 9.3 0.6 11.1 7.2 9.3 0.6 11.1 7.6 9.3 0.7 11.1 6.8 144 6 145 165 3.2 0 3.5 2.8 05/02/2006 12:00:00 9.1 0.6 10.7 7.2 9 0.6 11.1 7.2 9.3 0.6 10.7 7.2 148 4 145 165 3 0.1 3.3 2.6 05/02/2006 12:10:00 8.5 0.5 9.9 7.2 8.5 0.6 9.9 6.8 8.6 0.7 10.3 6.8 145 6 144 165 3.1 0 3.3 2.6 05/02/2006 12:20:00 8.6 0.6 9.9 6.8 8.5 0.6 9.9 6.5 8.5 0.7 9.9 5.7 144 5 150 165 3.2 0 3.3 2.8 05/02/2006 12:30:00 8.4 0.8 10.7 5.7 8.4 0.7 10.3 5.3 8.1 0.7 9.9 5.7 139 5 136 165 3.1 0 3.3 2.8 05/02/2006 12:40:00 8.8 0.8 11.5 6.5 8.8 0.8 11.1 6.5 8.6 1 11.1 4.9 138 5 135 165 3.2 0 3.5 2.8 05/02/2006 12:50:00 9.7 0.7 11.5 7.2 9.7 0.7 11.5 8 9.4 0.8 11.8 6.5 138 5 135 165 3.2 0 3.3 2.8 05/02/2006 13:00:00 10.1 0.6 12.6 8.4 10.1 0.7 12.2 8 10 0.9 12.2 6.8 139 5 142 165 3.2 0 3.3 2.8 05/02/2006 13:10:00 9 0.7 10.3 6.5 9 0.6 10.3 6.8 8.9 0.7 10.7 6.5 139 4 142 165 3.2 0 3.5 2.8 05/02/2006 13:20:00 9.1 0.8 11.5 6.8 9.2 0.8 11.5 7.2 8.8 1 11.5 5.7 136 5 136 165 3.2 0 3.5 2.8 05/02/2006 13:30:00 8.7 0.8 10.3 6.5 8.7 0.8 10.3 6.5 8.4 0.9 10.7 5.7 138 6 133 165 3.3 0 3.5 3.3 05/02/2006 13:40:00 8.5 0.9 10.7 6.5 8.5 0.9 10.3 6.5 8.4 1 10.3 5.7 139 6 140 165 3.3 0 3.5 3 05/02/2006 13:50:00 9.3 0.6 10.7 7.2 9.3 0.6 10.3 7.2 9.2 0.7 10.7 6.8 140 5 135 165 3.2 0 3.3 3.3 05/02/2006 14:00:00 8.2 0.8 10.7 6.5 8.3 0.8 10.3 6.5 8.2 0.9 10.7 6.5 143 6 147 165 3.3 0 3.5 3.3 05/02/2006 14:10:00 5.3 1.2 9.5 3.4 5.1 1.3 9.5 3 5.5 1.2 9.1 3.4 161 8 140 165 3.5 0 3.5 3.3 05/02/2006 14:20:00 3.4 0.4 4.6 2.3 3.3 0.4 4.6 2.3 3.4 0.5 4.6 2.3 163 5 162 165 3.5 0.1 3.8 3.3 05/02/2006 14:30:00 2.6 0.4 3.4 1.5 2.4 0.5 3.4 1.5 2.4 0.6 4.2 0.4 164 9 169 165 3.7 0 3.8 3.3 05/02/2006 14:40:00 2.6 0.3 3.4 1.9 2.5 0.3 3.4 1.9 2.4 0.3 3.4 1.5 154 7 165 165 3.8 0 4 3.5 05/02/2006 14:50:00 3.3 0.5 4.6 1.9 3.2 0.5 4.6 1.9 3.3 0.5 4.2 1.9 155 9 146 165 4 0.1 4.5 3.5 05/02/2006 15:00:00 4.4 0.6 6.1 2.6 4.3 0.6 5.7 2.6 4.3 0.5 5.7 3 151 6 150 165 4.3 0.1 4.5 4 05/02/2006 15:10:00 4.7 0.5 6.1 3.4 4.6 0.5 6.1 3 4.6 0.5 6.5 3 142 13 138 165 4.1 0.2 4.5 3.5 05/02/2006 15:20:00 4.8 0.7 6.5 2.6 4.7 0.7 6.1 2.6 4.8 0.7 6.5 2.6 142 8 145 165 3.7 0.2 4 3.3 05/02/2006 15:30:00 5.3 0.6 6.8 3.4 5.1 0.6 6.8 3 5.2 0.6 7.2 3.8 146 8 141 165 3.5 0.1 3.8 3 05/02/2006 15:40:00 4.4 0.4 5.7 3.4 4.3 0.4 5.7 3 4.4 0.4 5.3 3.4 138 6 137 165 3.6 0.1 3.8 3 05/02/2006 15:50:00 4.4 0.3 5.7 3.4 4.3 0.4 6.1 3.4 4.4 0.4 5.7 3.8 138 5 136 165 4 0.2 4.5 3.3 05/02/2006 16:00:00 4.9 0.6 6.1 3 4.9 0.6 6.1 3 4.9 0.6 6.1 3 139 6 122 165 4.3 0.2 4.8 3.8 05/02/2006 16:10:00 5.7 0.8 8 3.8 5.6 0.9 8.4 3.4 5.6 0.9 8 3.8 137 7 133 165 4.3 0.2 4.8 3.8 05/02/2006 16:20:00 7.8 0.7 9.5 6.1 7.8 0.7 9.1 6.1 7.8 0.7 9.1 5.7 140 5 139 165 3.8 0.1 4.3 3.3 05/02/2006 16:30:00 8.7 0.9 10.7 6.1 8.6 0.9 10.7 6.5 8.6 1 10.7 6.1 145 4 141 165 3.8 0 4 3.3 05/02/2006 16:40:00 9.2 0.6 10.3 7.6 9.1 0.6 10.3 7.6 9.3 0.6 10.7 7.6 151 4 149 165 3.6 0.1 3.8 3.3 05/02/2006 16:50:00 6.4 0.8 8.4 4.2 6.2 0.9 8.4 4.2 6.6 1 8.8 4.2 172 8 159 165 3.5 0 3.8 3 05/02/2006 17:00:00 5.5 0.5 6.5 4.2 5.3 0.5 6.5 4.2 5.4 0.5 6.5 4.2 156 12 169 165 3.3 0 3.8 3 05/02/2006 17:10:00 5.3 0.5 6.5 4.2 5.1 0.5 6.1 3.8 5.4 0.5 6.8 4.2 157 4 159 165 3.4 0 3.5 3.3 05/02/2006 17:20:00 4.7 0.4 5.7 3.8 4.5 0.4 5.7 3.8 4.9 0.4 6.1 3.8 157 5 164 165 3.4 0 3.5 2.8 05/02/2006 17:30:00 5.4 0.4 6.5 3.8 5.2 0.4 6.5 3.8 5.5 0.4 6.5 4.2 160 10 139 165 3.5 0 3.8 3.3 05/02/2006 17:40:00 6.5 0.4 7.2 4.9 6.2 0.4 7.2 4.9 6.5 0.4 7.2 4.9 163 3 164 165 3.3 0 3.5 3 05/02/2006 17:50:00 7.5 0.7 8.8 5.7 7.3 0.7 8.4 5.7 7.6 0.8 8.8 5.7 152 2 153 165 3.3 0 3.5 2.8 05/02/2006 18:00:00 7.5 0.4 8.8 6.1 7.4 0.4 8.4 6.1 7.6 0.4 8.8 6.1 149 4 150 165 3.2 0 3.3 2.8 05/02/2006 18:10:00 7.5 0.4 8.8 6.5 7.4 0.4 8.8 6.1 7.7 0.4 8.8 6.5 156 4 159 165 3.3 0 3.5 3 05/02/2006 18:20:00 7.5 0.6 8.4 4.9 7.2 0.6 8.4 4.9 7.7 0.7 9.1 4.9 157 6 156 165 3.3 0 3.5 3.3 05/02/2006 18:30:00 6.2 0.6 7.2 4.9 5.9 0.6 6.8 4.6 6.3 0.6 7.6 4.9 169 4 173 165 3.1 0.1 3.5 2.8 05/02/2006 18:40:00 5.3 0.3 6.1 4.6 5.1 0.3 6.1 4.6 5.5 0.3 6.5 4.6 162 3 160 165 3.1 0 3.3 3 05/02/2006 18:50:00 4.8 0.5 5.7 3.4 4.6 0.5 5.3 3.4 5 0.5 6.1 3.8 162 3 165 165 3.2 0 3.3 3 05/02/2006 19:00:00 4.4 0.3 4.9 3.8 4.3 0.3 4.9 3.4 4.6 0.3 5.3 3.8 156 4 160 165 3 0 3.3 2.8 05/02/2006 19:10:00 4.7 0.3 5.7 3.8 4.6 0.3 5.3 3.8 4.8 0.3 5.7 3.8 150 3 147 165 3 0 3 2.8 05/02/2006 19:20:00 4.3 0.3 4.9 3.4 4.3 0.3 4.9 3.4 4.4 0.4 5.3 3.4 147 5 151 165 3 0 3 2.8 05/02/2006 19:30:00 5.6 0.7 7.2 3.8 5.7 0.7 7.2 4.2 5.5 0.8 7.2 3.4 141 5 138 165 3 0 3.3 2.8 05/02/2006 19:40:00 7.1 0.6 8.4 5.3 7.1 0.6 8.4 5.3 7 0.8 8.4 4.6 143 5 139 165 3 0 3.3 2.8 05/02/2006 19:50:00 8.3 0.9 10.3 6.5 8.2 0.8 9.9 6.5 8.4 1 10.7 6.5 152 6 156 165 3 0 3.3 2.8 05/02/2006 20:00:00 7.9 0.8 9.5 6.1 7.7 0.7 9.5 5.7 8.1 0.7 9.9 6.5 156 5 159 165 2.6 0.1 2.8 2.6 05/02/2006 20:10:00 5.7 0.8 8 3.8 5.6 0.8 8 4.2 5.7 0.9 8 4.2 158 5 158 165 2.5 0 2.8 2.3 05/02/2006 20:20:00 4.3 0.5 5.7 3.4 4.3 0.5 5.7 3 4.4 0.6 5.7 3 145 5 146 165 2.5 0 2.8 2.1 05/02/2006 20:30:00 5.8 0.8 7.6 4.6 5.8 0.8 7.6 4.6 5.9 0.8 8 4.2 142 5 137 165 2.6 0 2.8 2.3 05/02/2006 20:40:00 6.3 0.4 7.2 5.3 6.3 0.4 7.2 4.9 6.4 0.5 7.6 4.9 141 4 143 165 2.7 0 2.8 2.3 05/02/2006 20:50:00 6.2 0.6 8 4.6 6.2 0.6 7.6 4.6 6.1 0.6 7.6 4.6 141 8 144 165 2.7 0 2.8 2.3 05/02/2006 21:00:00 6.2 0.5 7.2 5.3 6.2 0.5 7.6 4.9 6.1 0.5 7.2 4.6 133 5 129 165 2.8 0 2.8 2.3 05/02/2006 21:10:00 6.7 0.8 8.4 4.6 6.7 0.7 8.4 4.6 6.7 0.8 8.8 4.6 132 7 129 165 2.9 0 3 2.3 05/02/2006 21:20:00 6.6 0.7 8 4.2 6.6 0.6 8.4 4.2 6.6 0.7 8 4.6 142 8 148 165 2.9 0 3 2.3 05/02/2006 21:30:00 5.4 0.9 7.2 3.8 5.4 0.9 7.2 3.8 5.5 0.9 7.2 3.8 148 3 144 165 2.8 0 3 2.3 05/02/2006 21:40:00 6.3 0.5 8 4.9 6.2 0.5 7.6 4.9 6.3 0.5 7.6 4.6 142 5 145 165 2.8 0 3 2.3 05/02/2006 21:50:00 6.1 0.5 7.2 4.9 6.2 0.5 7.2 4.6 6.2 0.5 7.2 4.9 138 4 142 165 2.9 0 3 2.6 05/02/2006 22:00:00 5.1 0.5 6.1 3.8 5.1 0.5 6.5 3.8 5.2 0.5 6.5 3.4 138 6 141 165 2.9 0 3.3 2.6 05/02/2006 22:10:00 6.5 0.9 8.4 4.6 6.6 0.9 8.4 4.9 6.3 0.9 8.4 4.2 119 6 112 165 2.8 0 3 2.3 05/02/2006 22:20:00 6.4 0.6 8.4 4.6 6.6 0.6 8.4 4.6 6.2 0.7 8 4.2 115 5 119 165 2.7 0 2.8 2.3 05/02/2006 22:30:00 6.4 0.4 7.2 4.9 6.6 0.4 7.6 4.9 6.3 0.5 7.2 4.6 113 5 113 165 2.5 0 2.8 2.3 05/02/2006 22:40:00 6.2 0.5 7.2 4.9 6.4 0.5 7.6 4.6 6 0.6 7.2 4.2 116 3 119 165 2.5 0 2.6 2.3 05/02/2006 22:50:00 6.1 0.4 7.2 4.9 6.2 0.4 7.2 4.6 5.7 0.6 6.8 3.8 114 3 114 165 2.6 0 2.8 2.6 05/02/2006 23:00:00 6.6 0.3 8 5.7 6.8 0.3 7.6 6.1 6.5 0.5 7.6 4.2 122 5 127 165 2.5 0 2.8 2.6 05/02/2006 23:10:00 6.7 0.5 8 5.7 6.9 0.5 8 5.7 6.6 0.6 8 4.2 120 4 125 165 2.5 0 2.8 2.6 05/02/2006 23:20:00 6.9 0.5 8.4 4.9 7 0.5 8.4 5.3 6.9 0.6 8.4 4.9 123 4 114 165 2.6 0 2.8 2.6 05/02/2006 23:30:00 6.4 0.3 7.2 5.3 6.6 0.3 7.2 5.3 6.2 0.5 7.2 3.8 117 3 109 165 2.6 0 2.8 2.6 05/02/2006 23:40:00 6.2 0.3 6.8 4.9 6.4 0.3 7.2 5.3 5.9 0.4 6.8 4.6 113 2 108 165 2.7 0 2.8 2.6 05/02/2006 23:50:00 5.6 0.3 6.5 4.6 5.9 0.3 6.8 4.9 5.5 0.5 6.5 3.4 106 4 101 165 2.8 0 2.8 2.6 05/03/2006 00:00:00 6 0.5 7.6 4.2 6.2 0.5 8 4.6 5.9 0.6 7.6 4.2 94 5 76 165 2.9 0 2.8 2.8 05/03/2006 00:10:00 6.2 0.4 7.2 4.9 6.5 0.4 7.6 5.3 6.2 0.5 7.2 4.9 92 4 91 165 2.9 0 3 2.8 05/03/2006 00:20:00 6.2 0.5 7.2 4.2 6.4 0.5 7.6 4.6 6 0.6 7.2 4.2 93 5 88 165 2.9 0 3 2.8 05/03/2006 00:30:00 6.4 0.6 8 4.6 6.6 0.6 8 4.6 6.1 0.6 7.2 4.6 96 7 91 165 2.9 0 3 2.8 05/03/2006 00:40:00 7.7 0.4 8.4 6.5 7.9 0.4 8.8 6.5 7.4 0.5 8.4 6.1 84 4 90 165 3 0 3 2.8 05/03/2006 00:50:00 7.6 0.5 8.8 5.3 7.9 0.5 9.1 5.3 7.5 0.5 8.8 5.7 82 3 75 165 3 0 3.3 2.8 05/03/2006 01:00:00 7 0.5 9.1 5.7 7.3 0.5 9.1 6.1 6.9 0.5 8 5.7 83 6 81 165 3 0 3.5 2.8 05/03/2006 01:10:00 7.4 0.5 8.8 5.3 7.7 0.5 8.8 5.7 7 0.6 8.8 4.9 90 4 91 165 3 0 3.3 2.6 05/03/2006 01:20:00 8.5 0.3 9.5 6.5 8.8 0.3 9.5 6.8 8.2 0.5 9.1 6.5 93 3 96 165 3 0 3.3 2.8 05/03/2006 01:30:00 9.4 0.8 11.1 7.2 9.6 0.8 11.5 7.2 8.8 1 11.1 5.7 94 4 93 165 3.2 0 3.5 2.8 05/03/2006 01:40:00 9.8 0.4 10.7 8 10.1 0.4 11.5 8 9.5 0.5 10.7 7.6 95 4 93 165 3.3 0 3.5 2.8 05/03/2006 01:50:00 10.3 0.5 11.5 8.4 10.7 0.5 11.8 8.4 9.9 0.8 11.1 6.8 94 3 94 165 3.4 0 3.5 2.8 05/03/2006 02:00:00 10.5 0.7 12.6 6.8 10.8 0.7 13 7.2 10 0.9 11.8 6.5 94 4 92 165 3.4 0.1 3.5 2.8 05/03/2006 02:10:00 10.7 0.6 11.8 8.4 11 0.7 12.6 8.4 10.3 0.9 12.2 7.6 93 4 89 165 3.5 0.1 3.5 2.8 05/03/2006 02:20:00 9.8 0.9 11.8 6.5 10.1 1 12.6 7.6 9.3 1.1 11.8 6.8 95 5 85 165 3.5 0.2 3.8 2.8 05/03/2006 02:30:00 10 0.9 11.8 7.2 10.2 0.9 11.8 8 9.4 1 11.8 6.8 99 5 99 165 3.5 0.1 3.5 2.8 05/03/2006 02:40:00 9.8 1 12.2 6.8 10.1 1 12.2 6.8 9.4 1 12.2 6.8 97 6 93 165 3.5 0.2 3.8 2.8 05/03/2006 02:50:00 10.4 1.2 14.1 7.2 10.6 1.3 14.5 7.2 9.8 1.3 13.3 6.5 97 9 102 165 3.5 0.2 3.5 2.6 05/03/2006 03:00:00 11 1.3 14.5 7.6 11.2 1.3 14.9 8 10.3 1.4 14.9 6.8 106 7 104 165 2.5 0.3 3.8 1.6 05/03/2006 03:10:00 8.4 0.9 10.7 6.1 8.6 1 11.1 6.1 7.7 1 9.9 4.6 102 5 96 165 2.2 0.3 2.8 1.8 05/03/2006 03:20:00 9.1 0.7 10.7 6.1 9.3 0.7 11.1 6.5 8.6 0.8 10.3 6.1 92 5 82 165 2.9 0.1 3.3 2.6 05/03/2006 03:30:00 9.3 0.7 10.7 6.8 9.6 0.8 11.1 6.8 8.9 0.9 10.7 5.7 87 6 86 165 3.1 0 3.3 2.8 05/03/2006 03:40:00 9.1 1 11.5 6.5 9.3 1.1 11.8 6.5 8.6 1 11.1 5.7 93 8 98 165 3 0 3.3 3 05/03/2006 03:50:00 8.5 0.9 10.7 6.1 8.8 0.9 11.1 6.5 8.1 0.9 10.7 5.7 92 8 98 165 3 0 3.3 2.8 05/03/2006 04:00:00 9.4 1 12.2 6.8 9.7 1 12.2 6.8 9.1 1 12.2 6.1 89 7 96 165 2.9 0 3 2.8 05/03/2006 04:10:00 9.9 1.4 12.6 6.5 10.2 1.4 13.3 6.5 9.4 1.4 12.2 6.1 94 8 98 165 2.9 0 3 2.8 05/03/2006 04:20:00 10.3 1 12.6 6.8 10.5 1 13 7.2 9.7 1 12.2 6.8 98 6 95 165 2.9 0 3 2.8 05/03/2006 04:30:00 9.6 1.1 13 6.8 9.9 1.2 13 7.2 9.2 1.2 12.6 6.1 94 7 95 165 2.9 0 3 2.8 05/03/2006 04:40:00 10.2 1.2 13 6.8 10.5 1.2 13.3 6.8 9.9 1.2 13 7.2 88 8 96 165 2.8 0 3 2.8 05/03/2006 04:50:00 9.6 1.5 13.7 6.1 9.9 1.5 14.1 6.1 9.3 1.4 13.3 6.1 90 7 97 165 2.9 0 3 2.6 05/03/2006 05:00:00 10.1 1.1 13.3 6.8 10.4 1.1 13.7 7.2 9.7 1.1 12.6 6.8 84 6 87 165 2.7 0 2.8 2.6 05/03/2006 05:10:00 9.5 1.2 12.6 6.1 9.8 1.2 13 6.5 9.2 1.1 12.2 5.7 78 7 77 165 2.7 0 2.8 2.6 05/03/2006 05:20:00 8.5 1 12.2 5.7 8.8 1 12.2 6.5 8.4 1 11.1 5.3 72 8 73 165 2.8 0 2.8 2.6 05/03/2006 05:30:00 9.1 1.3 13 6.1 9.4 1.3 13.3 6.8 8.9 1.2 13 6.1 76 8 70 165 2.9 0 3 2.6 05/03/2006 05:40:00 7.5 1.1 10.3 4.9 7.7 1.1 10.3 5.3 7.4 1 10.3 4.9 66 8 60 165 2.9 0 3 2.6 05/03/2006 05:50:00 7.6 1 9.9 5.3 7.8 1 10.3 5.3 7.4 1 9.9 4.9 66 7 72 165 2.9 0 3 2.6 05/03/2006 06:00:00 7.4 1.3 11.1 4.2 7.6 1.3 11.1 4.2 7.2 1.2 10.3 4.6 58 10 55 165 2.9 0.1 3.5 2.6 05/03/2006 06:10:00 8.1 1.2 11.8 5.3 8.2 1.2 11.5 5.3 7.9 1.3 11.5 4.9 49 8 41 165 3 0.1 3.3 2.6 05/03/2006 06:20:00 8.7 1.2 12.2 5.7 8.8 1.3 12.2 5.7 8.5 1.2 12.2 6.1 54 10 60 165 3 0.1 3.3 2.6 05/03/2006 06:30:00 8.4 1.2 11.1 4.6 8.6 1.3 11.1 4.2 8.1 1.2 10.7 5.3 56 9 29 165 3 0.1 3.3 2.6 05/03/2006 06:40:00 8.6 1.5 11.8 4.2 8.8 1.5 11.8 4.2 8.4 1.4 11.8 4.2 57 9 56 165 3.1 0.1 3.3 2.6 05/03/2006 06:50:00 8.6 1.7 13 4.9 8.8 1.8 13.3 4.9 8.3 1.6 12.6 4.6 59 10 63 165 3.2 0.1 3.5 2.6 05/03/2006 07:00:00 10 1.6 14.5 6.5 10.2 1.6 14.5 6.5 9.8 1.5 14.1 6.5 65 9 65 165 3.3 0.1 3.5 2.8 05/03/2006 07:10:00 10.3 1.5 14.9 6.5 10.4 1.7 14.9 6.5 9.9 1.6 13.7 5.7 58 9 43 165 3.3 0.1 3.5 2.8 05/03/2006 07:20:00 8.9 1.3 12.6 6.1 9 1.3 13 6.1 8.7 1.2 12.2 6.1 53 9 62 165 3.2 0.1 3.5 2.6 05/03/2006 07:30:00 9.6 1.5 15.3 6.5 9.7 1.7 15.3 6.5 9.2 1.6 14.9 5.7 57 9 54 165 3.2 0.1 3.5 2.8 05/03/2006 07:40:00 9.6 1.8 13.7 5.7 9.7 1.9 13.7 5.3 9.3 1.9 13.3 5.3 52 9 63 165 3.3 0 3.5 2.6 05/03/2006 07:50:00 9.4 1.7 14.1 4.9 9.5 1.8 14.1 4.9 9.1 1.7 14.1 5.3 49 10 44 165 3.3 0 3.5 3 05/03/2006 08:00:00 9.8 1.7 13.7 6.1 9.8 1.8 14.1 6.1 9.5 1.7 14.5 5.7 45 9 57 165 3.5 0 3.5 3 05/03/2006 08:10:00 9.5 1.3 13.3 6.5 9.5 1.4 13.7 6.1 9.3 1.3 13.3 5.7 38 8 47 165 3.5 0 3.8 3.3 05/03/2006 08:20:00 10.8 1.5 14.1 7.6 10.8 1.5 14.5 7.6 10.6 1.5 14.5 7.2 37 6 41 165 3.6 0 3.8 3.5 05/03/2006 08:30:00 9.9 1.1 13 6.8 9.9 1.2 13.3 6.5 9.6 1.3 12.6 6.1 35 8 33 165 3.6 0.1 3.8 3 05/03/2006 08:40:00 11.5 1.7 14.9 7.6 11.5 1.7 14.9 7.6 11.3 1.7 15.3 7.2 42 8 37 165 3.3 0 3.5 2.6 05/03/2006 08:50:00 11.8 1.5 16.1 8.4 11.8 1.6 16.4 8.4 11.5 1.6 16.1 7.2 36 7 43 165 3.5 0.1 3.8 2.8 05/03/2006 09:00:00 11.4 1.5 14.9 7.2 11.5 1.5 14.9 6.8 11.3 1.6 16.1 7.6 35 6 36 165 3.6 0.1 4 3.3 05/03/2006 09:10:00 11.8 1.6 16.8 8 11.8 1.6 16.4 8 11.4 1.7 16.8 7.2 34 7 51 165 3.5 0.1 3.8 3.3 05/03/2006 09:20:00 12 1.5 16.8 8 12 1.5 16.8 8.4 11.5 1.7 16.1 7.6 34 7 28 165 3.5 0.2 3.5 2.8 05/03/2006 09:30:00 11.5 1.5 14.5 7.6 11.4 1.6 14.5 7.6 11.1 1.5 15.3 8 32 8 32 165 3.5 0.1 3.5 2.8 05/03/2006 09:40:00 12.5 1.5 15.6 8.8 12.5 1.5 15.6 8.8 12.2 1.5 16.8 8.4 33 7 39 165 3.5 0.1 3.8 3 05/03/2006 09:50:00 13.5 1.7 17.6 8 13.4 1.7 17.9 6.5 13 1.7 17.2 6.8 32 8 37 165 3.5 0 3.8 3.3 05/03/2006 10:00:00 13 1.8 18.3 8.4 13 1.9 18.3 8 12.8 1.9 17.6 8.4 33 8 41 165 3.5 0.1 3.8 3 05/03/2006 10:10:00 14.2 1.6 17.2 9.5 14.2 1.7 17.6 8.8 13.6 1.8 18.7 7.6 37 7 46 165 3.5 0.1 3.8 2.8 05/03/2006 10:20:00 13.7 2.1 17.9 8.8 13.7 2.2 18.3 8.4 13.5 2.2 18.3 8.4 37 7 41 165 3.4 0 3.5 3.3 05/03/2006 10:30:00 14.1 1.7 18.3 9.1 14 1.8 18.7 9.5 13.7 1.8 18.3 8.4 31 8 48 165 3.3 0 3.5 3.3 05/03/2006 10:40:00 14.7 1.7 19.5 9.9 14.7 1.8 19.5 9.1 14.3 1.8 19.1 9.1 33 8 26 165 3.2 0 3.5 2.8 05/03/2006 10:50:00 14.7 1.9 19.1 9.5 14.7 2.1 19.1 9.1 14.4 2.1 19.5 9.5 34 8 35 165 3 0.1 3.3 2.6 05/03/2006 11:00:00 14.1 2.1 19.9 8.8 14 2.3 19.5 8.8 13.7 2.2 19.5 8.8 30 8 22 165 3 0 3.3 2.6 05/03/2006 11:10:00 14.8 2.1 19.1 9.5 14.7 2.2 19.1 9.5 14.4 2.3 19.1 9.1 31 7 41 165 2.9 0 3 2.3 05/03/2006 11:20:00 16.5 2.1 20.6 10.7 16.3 2.2 20.6 10.7 15.7 2.2 21 9.9 30 8 28 165 2.7 0.2 3 1.8 05/03/2006 11:30:00 14.9 2.1 19.1 9.9 14.8 2.2 19.5 9.5 14.5 1.9 19.5 8.8 31 8 32 165 2.5 0.1 2.8 1.8 05/03/2006 11:40:00 16.2 2.2 21 10.7 16.1 2.4 21 10.7 15.6 2.4 20.6 9.5 31 7 28 165 2.4 0.1 2.6 1.8 05/03/2006 11:50:00 16 1.7 19.9 11.1 15.7 1.8 19.5 10.7 15.3 1.8 20.2 10.7 24 9 32 165 2.4 0.1 2.6 1.8 05/03/2006 12:00:00 14.6 2.2 21 9.9 14.3 2.4 21.4 9.1 13.9 2.2 21 9.1 25 9 29 165 2.5 0 2.8 2.1 05/03/2006 12:10:00 15.9 2.2 21.4 10.7 15.5 2.5 21.8 9.9 15.4 2.3 21 10.7 24 8 35 165 2.5 0.1 2.8 2.3 05/03/2006 12:20:00 15.2 2.6 21.8 9.5 14.6 3.1 21.4 7.6 14.7 2.5 20.6 9.9 22 9 32 165 2.4 0 2.6 2.3 05/03/2006 12:30:00 14.5 2.1 19.1 9.5 13.7 2.2 19.1 8.8 13.9 2.1 19.1 9.1 21 9 18 165 2.4 0 2.8 2.3 05/03/2006 12:40:00 14.1 1.7 17.9 9.9 12.9 2.3 17.6 6.5 13.9 1.6 17.6 10.3 18 8 31 165 2.3 0 2.6 2.1 05/03/2006 12:50:00 15.7 1.6 19.5 11.5 13.6 1.8 17.9 8.4 15.3 1.8 21 10.7 14 6 14 165 2.1 0 2.6 1.8 05/03/2006 13:00:00 15.7 1.7 19.1 10.3 14.3 2.3 19.5 9.1 15.4 1.8 20.2 10.3 16 6 26 165 2.1 0 2.3 1.8 05/03/2006 13:10:00 16.2 1.6 19.9 11.1 13.9 2.4 19.1 8.8 15.7 1.7 19.5 11.5 14 6 12 165 2.2 0 2.3 2.1 05/03/2006 13:20:00 16 1.7 20.2 10.7 13.6 2.4 18.7 7.6 15.7 1.8 19.5 10.7 13 6 18 165 2.3 0 2.3 2.1 05/03/2006 13:30:00 17.1 1.6 21 12.6 15.5 2.2 20.6 9.9 16.6 1.7 21 12.6 16 7 21 165 2.3 0 2.3 2.3 05/03/2006 13:40:00 16.9 2.1 21.8 11.5 15.1 2.6 21.4 8.4 16.1 2.2 21.8 10.3 16 6 16 165 2.3 0 2.6 2.3 05/03/2006 13:50:00 17.2 2 20.6 11.8 15.7 2.5 20.2 8.8 16.9 2.1 21.8 11.8 15 6 23 165 2.3 0 2.6 2.3 05/03/2006 14:00:00 16.6 1.7 21 11.1 14.6 2.5 21 8.4 16.3 1.7 21 11.5 14 7 22 165 2.3 0 2.6 2.3 05/03/2006 14:10:00 16.5 1.9 21 11.5 14.9 2.6 21 7.6 16.1 2.3 21.4 11.5 16 7 18 165 2.3 0 2.6 2.3 05/03/2006 14:20:00 14.6 1.8 19.5 10.7 12.3 2.5 19.1 7.2 14.3 1.9 19.9 10.3 13 7 16 165 2.3 0 2.6 2.3 05/03/2006 14:30:00 14.1 1.9 19.5 9.1 11.7 2.4 17.9 6.5 13.9 1.9 20.2 9.1 12 9 20 165 2.4 0 2.6 1.8 05/03/2006 14:40:00 14.3 1.7 19.1 10.3 11.4 2.1 17.2 6.5 14 1.9 19.9 9.9 10 7 1 165 2.2 0 2.3 1.8 05/03/2006 14:50:00 14.9 1.8 19.1 9.9 12.4 2.3 17.6 6.5 14.7 1.9 19.1 9.5 12 7 10 165 2.3 0 2.6 1.8 05/03/2006 15:00:00 14.7 1.8 18.7 9.5 11.3 2.4 18.3 6.5 14.6 1.9 19.9 10.3 9 7 18 165 2.3 0 2.6 1.8 05/03/2006 15:10:00 15.6 1.7 20.2 11.8 12.6 2.6 19.5 7.6 15.2 1.7 19.5 11.8 11 7 18 165 2.4 0 2.8 2.1 05/03/2006 15:20:00 15.3 1.7 19.5 11.1 12.9 2.5 19.1 7.2 15.1 1.9 20.6 10.3 12 8 0 165 2.6 0 2.8 2.3 05/03/2006 15:30:00 16.1 1.9 20.2 10.3 13.6 2.6 19.1 7.2 15.9 1.9 20.6 10.7 12 7 13 165 2.7 0 2.8 2.6 05/03/2006 15:40:00 16.7 1.9 21 12.2 14.4 2.5 20.6 8.4 16.1 1.9 21.8 11.5 12 7 18 165 2.7 0 2.8 2.6 05/03/2006 15:50:00 16.9 2.1 21.4 12.2 14.7 2.7 20.6 8.8 16.6 2.2 21.8 12.6 13 7 12 165 2.8 0 2.8 2.3 05/03/2006 16:00:00 17.2 2 21.4 11.5 14.8 2.7 20.2 8.8 16.8 2.1 21.4 12.2 13 7 18 165 2.9 0 3 2.3 05/03/2006 16:10:00 15.2 1.8 20.2 10.7 13 2.2 19.9 8.4 15 1.9 19.9 10.3 12 7 18 165 2.9 0 3 2.6 05/03/2006 16:20:00 17.3 1.8 21 12.2 15.2 2.6 20.6 8.8 16.9 2 20.6 11.8 14 7 2 165 2.8 0 2.8 2.3 05/03/2006 16:30:00 15.1 1.5 18.7 10.3 12.7 2.2 18.3 8 14.9 1.7 19.1 10.3 12 6 12 165 2.9 0 3 2.6 05/03/2006 16:40:00 15.6 1.7 20.2 10.7 12.9 2.3 19.1 7.2 15.3 1.7 20.2 10.7 10 7 7 165 2.8 0 3 2.6 05/03/2006 16:50:00 15.7 2 20.6 11.5 13.1 2.5 20.2 7.6 15.6 2.1 21 11.1 11 7 8 165 2.9 0 3 2.6 05/03/2006 17:00:00 16.1 1.9 20.2 9.9 14.3 2.5 20.2 8.4 15.9 1.8 21 11.1 15 7 15 165 2.9 0 3.3 2.6 05/03/2006 17:10:00 16.9 1.7 22.6 12.2 14.5 2.6 21.4 9.1 16.4 1.7 22.6 12.6 13 7 12 165 2.9 0 3 2.6 05/03/2006 17:20:00 16.4 1.8 21.8 11.1 12.7 2.3 19.5 7.2 16.3 1.9 20.6 11.1 8 6 14 165 2.9 0 3 2.6 05/03/2006 17:30:00 16.1 1.9 21.4 11.5 13.6 2.7 21.4 8.4 15.8 1.9 21 11.1 12 7 16 165 3 0.1 3.3 2.6 05/03/2006 17:40:00 16.1 1.7 19.9 11.1 13.4 2.5 19.5 7.6 15.8 1.7 20.6 11.8 11 8 19 165 3 0 3.3 2.6 05/03/2006 17:50:00 17.1 1.7 21.8 12.6 15 2.7 21.4 9.1 16.7 1.6 21 12.2 13 8 20 165 2.9 0.1 3.3 2.3 05/03/2006 18:00:00 16.1 2.1 21 10.7 13.5 2.8 21.4 8 15.9 2.2 21.4 10.7 12 8 15 165 2.7 0 3.3 2.3 05/03/2006 18:10:00 14.3 1.9 21 9.9 11.3 2.5 19.5 7.2 14 2 20.2 9.5 9 8 14 165 2.7 0 2.8 2.3 05/03/2006 18:20:00 12.6 1.5 17.2 8.8 9.3 1.7 14.9 5.7 12.7 1.7 16.8 8.8 4 7 344 165 2.7 0 3 2.3 05/03/2006 18:30:00 13.6 1.8 19.5 9.1 11 2 16.8 6.8 13.6 1.9 19.9 9.1 2 10 358 165 2.7 0 2.8 2.1 05/03/2006 18:40:00 13.1 2.1 19.9 9.5 10.2 2.4 17.9 6.1 13.1 2.1 19.1 8.4 0 8 356 165 2.7 0 2.8 2.3 05/03/2006 18:50:00 13.8 1.8 19.1 9.9 10 2.1 16.8 6.1 13.8 1.9 19.1 9.5 360 6 356 165 2.6 0 2.8 2.1 05/03/2006 19:00:00 14 1.5 18.3 9.9 9.9 1.6 15.3 6.1 14 1.6 18.7 9.9 1 6 5 165 2.6 0 2.8 2.1 05/03/2006 19:10:00 12.7 1.5 17.6 8.4 9.6 2 16.8 6.1 12.6 1.5 17.9 8.8 358 8 359 165 2.5 0 2.6 2.3 05/03/2006 19:20:00 11.5 1.5 17.2 7.6 8.9 1.9 15.3 5.7 11.4 1.6 16.4 7.6 359 8 359 165 2.4 0.1 2.8 1.8 05/03/2006 19:30:00 11.6 1.7 16.8 8 9.5 1.8 16.1 5.7 11.3 1.6 16.8 7.2 356 9 4 165 2.6 0 2.8 1.8 05/03/2006 19:40:00 11.3 1.3 16.1 8.8 9.4 1.8 14.5 5.7 11.1 1.4 16.8 7.6 354 7 354 165 2.7 0.1 2.8 2.1 05/03/2006 19:50:00 11.6 1.3 14.5 8 9.4 1.7 14.1 5.3 11.5 1.1 14.5 8.8 355 8 357 165 2.7 0.1 3 2.1 05/03/2006 20:00:00 9.2 1.2 11.8 4.9 8.1 1.4 12.2 4.2 9.3 1.4 13 4.9 351 9 0 165 2.7 0 3 2.3 05/03/2006 20:10:00 8.7 1.1 11.8 6.5 8.1 1.5 11.8 4.6 8.7 1.1 12.2 6.1 348 8 351 165 2.6 0 2.8 2.3 05/03/2006 20:20:00 9.5 1 12.6 6.8 9 1.2 12.6 5.3 9.5 1.1 14.1 6.8 348 7 350 165 2.8 0.1 3 2.3 05/03/2006 20:30:00 7.2 0.6 9.5 4.9 7.2 0.7 9.9 5.3 7.2 0.8 9.1 4.9 341 9 3 165 2.8 0.1 3 2.6 05/03/2006 20:40:00 7.8 1.1 11.1 5.3 7.8 1.3 11.1 4.2 7.8 1.1 10.7 5.3 341 8 355 165 2.8 0.1 3 2.3 05/03/2006 20:50:00 8.2 0.9 11.8 6.5 8.2 0.9 12.6 5.7 8.2 0.9 11.1 6.1 341 7 344 165 2.9 0.1 3 2.6 05/03/2006 21:00:00 8.1 1 11.1 6.1 8.1 1.1 10.7 5.3 8.2 1.1 11.8 5.7 341 7 336 165 3 0.1 3.3 2.6 05/03/2006 21:10:00 8.2 0.7 10.3 6.1 8 1 10.3 4.6 8.3 0.6 10.7 6.5 345 8 353 165 3 0 3.3 2.8 05/03/2006 21:20:00 7.9 0.9 10.7 5.7 8 0.9 10.3 5.7 8 1 11.1 5.7 336 8 336 165 3.2 0 3.5 2.6 05/03/2006 21:30:00 7.1 1 9.9 4.6 7.2 1 9.9 4.9 7.2 0.9 9.9 5.3 337 8 333 165 3.2 0 3.5 2.8 05/03/2006 21:40:00 7.6 0.9 9.9 5.3 7.6 1 10.3 4.6 7.8 1 10.3 5.3 338 9 332 165 3.3 0 3.5 2.8 05/03/2006 21:50:00 7 0.9 9.1 5.3 7 1 9.1 3.8 7.2 0.8 9.1 5.3 337 8 341 165 3.2 0.2 3.5 2.6 05/03/2006 22:00:00 6.9 1 9.1 4.2 6.5 1.7 9.5 2.6 7.1 0.9 9.1 5.3 346 8 344 165 3.3 0.1 3.5 2.8 05/03/2006 22:10:00 6.4 0.7 8.4 4.2 6.5 0.8 8.8 3 6.7 0.7 8.8 4.6 340 7 339 165 3.3 0.2 3.5 2.8 05/03/2006 22:20:00 5.5 0.6 6.8 4.2 5.4 0.9 7.2 2.3 5.9 0.6 7.6 4.2 344 9 349 165 3.2 0.3 3.8 2.8 05/03/2006 22:30:00 4.8 0.4 6.1 3.8 4.9 0.4 6.5 3.8 4.9 0.5 6.5 3.8 335 6 344 165 3.4 0.2 3.8 3 05/03/2006 22:40:00 3.2 0.5 4.9 1.9 3.2 0.5 4.9 2.3 3.4 0.4 4.9 2.3 327 7 339 165 3.3 0.2 3.5 2.8 05/03/2006 22:50:00 3.1 0.4 4.2 2.3 3.2 0.4 4.2 2.3 3.2 0.4 3.8 1.9 322 10 335 165 3.3 0.2 3.5 2.8 05/03/2006 23:00:00 2.7 0.3 3.4 1.9 2.9 0.3 3.8 2.3 2.7 0.4 3.4 1.5 309 4 305 165 3.3 0.2 3.5 2.8 05/03/2006 23:10:00 1.7 0.9 3.4 0.4 1.8 0.9 3.4 0.4 1.9 0.7 3.4 0.4 307 19 312 165 3.2 0.2 3.5 2.6 05/03/2006 23:20:00 0.8 0.6 2.6 0.4 0.8 0.6 2.3 0.4 0.9 0.5 2.3 0.4 200 72 200 165 3.3 0.2 3.8 2.8 05/03/2006 23:30:00 2.4 0.5 3.8 0.7 2.4 0.5 3.8 0.7 2.2 0.6 3.4 0.4 111 21 124 165 3.5 0.2 3.8 3 05/03/2006 23:40:00 3.1 0.6 4.2 1.5 3.2 0.6 4.6 1.5 3.5 0.6 4.9 1.9 220 22 246 165 3.2 0.2 3.8 2.6 05/03/2006 23:50:00 3.4 0.5 4.6 2.3 3.6 0.5 4.6 2.3 3.5 0.5 4.6 2.3 215 17 247 165 2.8 0.1 3 2.6 05/04/2006 00:00:00 5.1 0.8 6.5 3 5 0.7 6.1 3 5.2 0.8 6.5 3 172 9 164 165 3.1 0.1 3.5 2.6 05/04/2006 00:10:00 5.7 0.8 8 3.4 5.7 0.8 8 3.8 5.7 0.8 7.6 4.2 153 11 145 165 3.2 0.3 3.5 2.6 05/04/2006 00:20:00 6.2 0.4 7.2 5.3 6.2 0.4 7.6 5.3 6.1 0.4 7.2 4.9 144 5 144 165 3.4 0.2 3.5 2.8 05/04/2006 00:30:00 8.8 0.9 10.3 6.1 8.8 0.9 10.7 6.5 8.5 1 10.7 6.1 144 5 145 165 3.5 0.2 3.8 3 05/04/2006 00:40:00 9.2 0.5 10.7 8 9.2 0.5 10.7 8 9.2 0.6 10.7 7.2 149 3 146 165 3.6 0.1 3.8 3.3 05/04/2006 00:50:00 9.2 0.4 10.3 7.6 9.2 0.4 10.3 7.6 9.1 0.6 10.3 7.2 148 3 148 165 3.5 0.1 3.8 3.3 05/04/2006 01:00:00 9.1 0.4 10.7 8 9.2 0.4 10.7 8 9.1 0.5 10.3 7.6 149 3 145 165 3.6 0.1 4 3.3 05/04/2006 01:10:00 8.2 0.6 9.5 6.5 8.2 0.6 9.5 6.5 8.2 0.7 9.5 6.5 152 4 150 165 3.5 0.1 3.8 3.3 05/04/2006 01:20:00 6.4 0.7 8.4 4.9 6.5 0.6 8 4.9 6.3 0.7 8 4.6 153 4 157 165 3.4 0.2 3.5 3 05/04/2006 01:30:00 5.8 0.4 6.8 4.9 5.9 0.4 6.8 4.9 6 0.4 6.8 5.3 151 4 148 165 3.3 0.2 3.5 2.8 05/04/2006 01:40:00 5.6 0.3 6.5 4.9 5.7 0.3 6.5 4.9 5.8 0.4 6.5 4.6 151 3 149 165 3.3 0.2 3.5 2.8 05/04/2006 01:50:00 6 0.5 7.6 4.6 6.1 0.5 7.6 4.9 6.1 0.5 7.6 4.9 151 3 148 165 3.2 0.2 3.5 2.8 05/04/2006 02:00:00 6.6 0.5 8.4 5.3 6.6 0.5 8.4 4.9 6.7 0.6 8.4 5.3 152 3 150 165 3.2 0.2 3.5 2.8 05/04/2006 02:10:00 6.1 0.4 7.2 5.3 6.1 0.4 7.2 5.3 6.3 0.4 7.2 5.3 156 2 162 165 3.2 0.2 3.5 2.6 05/04/2006 02:20:00 5.9 0.3 6.8 5.3 6 0.3 6.8 5.3 6.2 0.4 7.2 5.3 153 3 164 165 3.2 0.2 3.5 2.8 05/04/2006 02:30:00 5.6 0.3 6.1 4.6 5.7 0.3 6.5 4.9 5.8 0.3 6.5 4.9 150 2 145 165 3.1 0.2 3.5 2.6 05/04/2006 02:40:00 4.9 0.4 6.1 3.8 5.1 0.4 6.1 4.2 5.1 0.4 6.1 3.8 149 4 154 165 3 0.2 3.5 2.6 05/04/2006 02:50:00 4.9 0.4 6.1 3.8 5 0.4 6.1 4.2 5.1 0.5 6.1 3.8 148 5 144 165 3 0.3 3.3 2.6 05/04/2006 03:00:00 5.1 0.6 6.5 3.8 5.3 0.6 6.5 4.2 5.2 0.6 6.8 4.2 144 6 142 165 3 0.2 3.3 2.6 05/04/2006 03:10:00 5.3 0.4 6.5 4.2 5.4 0.4 6.5 4.6 5.3 0.5 6.1 3.8 143 5 140 165 2.9 0.3 3.3 2.6 05/04/2006 03:20:00 5.3 0.4 6.5 4.2 5.5 0.4 6.5 4.6 5.3 0.4 6.1 3.8 144 4 147 165 3 0.1 3 2.6 05/04/2006 03:30:00 5.2 0.4 6.1 4.2 5.4 0.4 6.1 4.6 5.2 0.4 6.1 3.8 140 5 147 165 3 0.1 3.3 2.6 05/04/2006 03:40:00 5.8 0.6 7.6 4.2 5.9 0.6 7.6 4.6 5.8 0.6 7.6 4.6 144 6 137 165 2.9 0.2 3.3 2.6 05/04/2006 03:50:00 7.5 0.5 8.8 6.5 7.5 0.4 8.4 6.5 7.6 0.5 9.1 6.5 152 4 151 165 2.9 0.2 3.3 2.6 05/04/2006 04:00:00 5.9 0.8 8 4.2 5.9 0.7 7.6 4.2 6 0.8 8 4.2 154 4 156 165 2.9 0 3.3 2.3 05/04/2006 04:10:00 4.2 0.7 5.7 2.3 4.2 0.6 5.7 2.3 4.4 0.6 5.7 2.3 158 4 151 165 2.9 0 3 2.6 05/04/2006 04:20:00 2.8 0.6 4.2 1.1 2.9 0.5 4.2 1.5 2.9 0.4 4.2 1.9 156 7 151 165 2.9 0 3 2.6 05/04/2006 04:30:00 3.9 0.4 5.7 3 4 0.4 5.7 3 3.8 0.4 5.3 2.6 141 5 142 165 2.9 0 3 2.6 05/04/2006 04:40:00 4.2 0.5 5.7 2.6 4.2 0.5 5.7 2.6 4.3 0.5 5.3 3 146 9 145 165 2.9 0 3 2.6 05/04/2006 04:50:00 5.1 0.4 6.1 4.2 5.3 0.4 6.1 4.2 5.2 0.4 6.5 3.8 142 5 124 165 2.9 0.1 3 2.6 05/04/2006 05:00:00 4.9 0.4 6.1 3.8 5 0.4 6.1 3.8 5.1 0.4 6.1 3.8 145 5 143 165 2.9 0.2 3 2.6 05/04/2006 05:10:00 5.6 0.4 6.5 4.6 5.6 0.4 6.5 4.6 5.8 0.4 6.5 4.6 151 6 154 165 2.8 0.2 3.3 2.3 05/04/2006 05:20:00 5 0.5 6.1 3.8 4.9 0.5 6.1 3.8 5.2 0.5 6.5 4.2 154 9 157 165 2.9 0.2 3.3 2.6 05/04/2006 05:30:00 4.9 0.4 5.7 3.4 5 0.4 6.1 3.4 4.9 0.5 6.1 3.4 139 8 131 165 2.9 0.2 3.3 2.6 05/04/2006 05:40:00 4.9 0.5 6.1 3.8 5 0.4 6.1 3.8 5 0.5 6.1 3.8 151 5 143 165 3 0.1 3.3 2.6 05/04/2006 05:50:00 4.1 0.4 5.3 3.4 4.2 0.4 5.3 3.4 4.3 0.4 5.3 3 156 5 162 165 3 0.1 3.3 2.6 05/04/2006 06:00:00 3.3 0.4 4.6 2.3 3.3 0.4 4.2 2.3 3.5 0.3 4.6 2.6 156 4 153 165 3 0.1 3.3 2.8 05/04/2006 06:10:00 2.9 0.5 3.8 1.1 3 0.5 3.8 1.5 3.1 0.5 4.2 1.9 158 8 143 165 2.9 0.1 3.3 2.6 05/04/2006 06:20:00 3.1 0.5 4.2 1.9 3.2 0.4 4.2 1.9 3.4 0.4 4.6 2.6 154 6 154 165 2.9 0.1 3.3 2.6 05/04/2006 06:30:00 3.2 0.5 4.9 1.9 3.2 0.5 4.6 1.9 3.4 0.4 4.6 2.3 162 8 166 165 3 0 3.3 2.8 05/04/2006 06:40:00 2.6 0.5 3.8 1.5 2.7 0.5 3.8 1.5 2.9 0.5 4.6 1.1 163 9 162 165 2.9 0.1 3.3 2.6 05/04/2006 06:50:00 3.2 0.5 4.6 1.9 3.3 0.5 4.6 1.9 3.4 0.4 4.6 2.3 159 10 199 165 2.9 0.1 3.3 2.6 05/04/2006 07:00:00 3.1 0.5 4.2 1.9 3.1 0.5 4.2 1.9 3.3 0.4 4.6 2.3 161 6 165 165 2.9 0 3.3 2.8 05/04/2006 07:10:00 3.4 0.5 4.6 2.3 3.4 0.5 4.6 2.3 3.6 0.5 4.6 2.6 158 7 164 165 3.1 0 3.3 2.8 05/04/2006 07:20:00 3.5 0.3 4.2 2.6 3.5 0.3 4.2 2.6 3.8 0.4 4.6 3 163 5 153 165 3.2 0 3.5 2.8 05/04/2006 07:30:00 3.8 0.5 5.3 2.6 3.8 0.4 4.9 3 4 0.5 5.3 2.6 167 5 165 165 3.2 0 3.5 2.8 05/04/2006 07:40:00 4.1 0.4 4.9 3 4 0.3 4.9 3 4.3 0.4 5.3 3.4 168 6 165 165 3.2 0 3.5 2.8 05/04/2006 07:50:00 3.8 0.5 4.9 2.6 3.7 0.4 4.9 2.6 4 0.5 5.3 3 169 7 179 165 3.1 0.1 3.5 2.8 05/04/2006 08:00:00 4 0.4 5.3 3 4 0.4 4.9 3 4.3 0.3 5.3 3.4 162 11 173 165 3.4 0.1 3.5 2.8 05/04/2006 08:10:00 3.8 0.4 4.9 2.6 3.8 0.4 4.9 2.6 4.1 0.4 4.9 3 162 12 165 165 3.4 0.1 3.8 2.8 05/04/2006 08:20:00 3.7 0.5 4.9 2.3 3.6 0.5 4.6 2.3 3.9 0.5 5.3 2.6 163 10 183 165 3.6 0.1 4 3.3 05/04/2006 08:30:00 3.4 0.4 4.6 2.6 3.5 0.4 4.6 2.6 3.6 0.4 4.6 2.6 170 8 170 165 3.9 0 4.3 3.5 05/04/2006 08:40:00 4 0.4 4.9 3 4 0.4 5.3 3 4.3 0.4 5.3 3 156 9 164 165 4 0.1 4.3 3.5 05/04/2006 08:50:00 4.5 0.4 5.7 3.8 4.5 0.4 5.7 3.8 4.7 0.4 5.7 3.4 154 4 153 165 3.8 0 4 3.5 05/04/2006 09:00:00 5.6 0.4 6.8 4.6 5.5 0.4 6.5 4.6 5.8 0.4 6.5 4.9 154 3 144 165 3.8 0 4.3 3.5 05/04/2006 09:10:00 6.2 0.3 6.8 5.3 6.1 0.3 6.5 5.3 6.3 0.4 7.2 5.3 155 2 157 165 3.6 0 3.8 3.3 05/04/2006 09:20:00 4.7 0.5 6.1 3.8 4.6 0.5 5.7 3.8 4.9 0.4 6.1 3.8 157 5 153 165 3.6 0.1 3.8 3.5 05/04/2006 09:30:00 4.6 0.3 5.3 3.8 4.5 0.3 5.3 3.8 4.9 0.3 6.1 3.8 160 4 157 165 3.6 0 4 3.5 05/04/2006 09:40:00 4.1 0.4 4.9 2.6 4.2 0.4 4.9 2.6 4.4 0.4 5.3 3.4 165 5 168 165 4 0 4.3 3.5 05/04/2006 09:50:00 4.8 0.5 6.1 3.8 4.8 0.5 6.1 3.8 4.9 0.4 6.1 3.8 156 7 150 165 3.8 0 4 3.3 05/04/2006 10:00:00 5.1 0.4 6.1 4.2 5 0.4 6.1 3.8 5.3 0.4 6.8 3.8 157 5 158 165 4.4 0.3 5 3.5 05/04/2006 10:10:00 5.1 0.4 6.1 4.2 5.1 0.4 6.1 4.2 5.3 0.4 6.5 4.6 156 9 161 165 4.4 0.3 5 4 05/04/2006 10:20:00 5.3 0.4 6.5 3.8 5.2 0.4 6.1 3.8 5.4 0.4 6.5 4.6 154 9 154 165 3.9 0 4.3 3.5 05/04/2006 10:30:00 4.7 0.4 5.7 3.8 4.7 0.4 6.1 3.4 5 0.4 6.1 3.8 148 5 147 165 4.3 0 4.8 3.8 05/04/2006 10:40:00 5 0.4 6.1 3.8 4.9 0.4 6.1 3.4 5.2 0.5 6.1 3.8 154 9 161 165 4.7 0.1 5 4 05/04/2006 10:50:00 5.4 0.3 6.5 4.6 5.3 0.4 6.1 4.2 5.5 0.3 6.5 4.6 149 6 147 165 4.5 0 4.8 4.3 05/04/2006 11:00:00 5.8 0.4 6.8 4.6 5.8 0.5 6.8 4.6 5.9 0.5 7.2 4.2 139 5 129 165 4.5 0 4.8 4.5 05/04/2006 11:10:00 6.4 0.5 7.6 4.9 6.4 0.5 7.6 4.9 6.6 0.5 8.4 4.9 141 6 143 165 4.9 0.2 5.2 4.5 05/04/2006 11:20:00 7.3 0.5 8.4 6.1 7.2 0.5 8.4 5.7 7.5 0.5 8.8 6.1 149 4 152 165 5.1 0 5.5 5 05/04/2006 11:30:00 8.1 0.3 8.8 7.2 8 0.3 8.8 7.2 8.3 0.3 9.1 6.8 149 3 148 165 4.6 0.1 5 4.5 05/04/2006 11:40:00 8.3 0.5 9.5 7.2 8.3 0.5 9.5 7.2 8.5 0.5 9.9 7.2 147 3 144 165 4.3 0 4.8 3.8 05/04/2006 11:50:00 6.1 0.9 8 4.2 6 0.9 8 4.6 6.3 0.9 8.4 4.6 151 4 149 165 4.5 0 4.8 4.3 05/04/2006 12:00:00 5.2 0.3 5.7 4.2 5.2 0.3 6.1 4.2 5.3 0.3 6.1 4.2 150 4 152 165 4.4 0 4.5 4.3 05/04/2006 12:10:00 5.2 0.3 6.5 4.6 5.2 0.3 6.5 4.6 5.4 0.4 6.5 4.2 145 4 144 165 4.3 0 4.5 4.3 05/04/2006 12:20:00 6.2 0.4 7.2 4.9 6.2 0.4 7.6 4.9 6.3 0.4 7.2 5.3 150 4 152 165 4.4 0 4.5 4.3 05/04/2006 12:30:00 6.1 0.4 6.8 5.3 6.2 0.4 7.2 5.3 6.3 0.5 7.2 4.6 145 4 142 165 4.7 0 5 4.5 05/04/2006 12:40:00 6.7 0.5 8 5.7 6.8 0.4 8 5.3 6.9 0.5 8 5.3 145 4 141 165 5.1 0.1 5.5 4.8 05/04/2006 12:50:00 7 0.4 8 6.1 7 0.4 8 5.7 7.1 0.5 8.4 5.7 147 6 151 165 4.8 0.1 5.2 4.3 05/04/2006 13:00:00 7 0.4 8.4 6.1 7 0.4 8.4 6.1 7 0.6 8.4 4.9 148 4 151 165 4.9 0.1 5.5 4.5 05/04/2006 13:10:00 7.1 0.5 8.8 5.7 7.2 0.5 8.8 5.7 7.2 0.6 8.8 5.7 146 6 140 165 4.9 0.3 5.5 4.3 05/04/2006 13:20:00 7.6 0.8 9.5 5.7 7.5 0.7 9.1 5.7 7.8 0.8 9.5 5.7 155 8 165 165 4.8 0 5 4.5 05/04/2006 13:30:00 8.2 0.7 9.5 6.5 8.1 0.6 9.5 6.5 8.5 0.8 9.9 6.5 160 15 151 165 4.9 0 5 4.8 05/04/2006 13:40:00 8.5 0.7 9.9 6.1 8.2 0.7 9.5 6.1 8.7 0.8 9.9 6.1 169 9 164 165 4.9 0.2 5.2 4.5 05/04/2006 13:50:00 8.6 0.5 9.9 6.8 8.3 0.5 9.5 6.5 8.9 0.5 10.3 7.2 170 4 170 165 5.3 0.1 5.7 4.8 05/04/2006 14:00:00 7.9 0.6 9.1 6.1 7.7 0.5 9.1 6.5 8.2 0.6 9.5 6.5 163 9 166 165 5.6 0 5.7 5 05/04/2006 14:10:00 8.9 0.8 10.7 6.8 8.7 0.7 10.3 6.8 9.2 0.8 10.7 7.2 162 8 160 165 5.7 0 5.7 5.2 05/04/2006 14:20:00 9.2 0.6 10.3 7.2 9.1 0.5 10.3 7.6 9.5 0.6 11.1 7.6 161 11 161 165 5.7 0.1 6 5.2 05/04/2006 14:30:00 8.3 0.6 9.9 6.8 8.3 0.6 9.5 6.8 8.5 0.6 9.9 6.8 151 5 164 165 5.4 0.2 6 5 05/04/2006 14:40:00 9.8 0.8 11.1 8 9.8 0.7 11.1 8 10 0.7 11.1 8 149 4 144 165 4.7 0.2 5.5 4.3 05/04/2006 14:50:00 10 0.4 11.1 8.4 9.9 0.4 10.7 8.4 9.9 0.6 11.5 8 152 3 152 165 4.5 0 4.8 4.3 05/04/2006 15:00:00 9 0.6 10.3 7.2 9 0.5 10.3 7.2 9 0.7 10.3 7.2 148 3 154 165 4.6 0 4.8 4.5 05/04/2006 15:10:00 8.7 0.4 9.5 7.6 8.7 0.4 9.5 7.6 8.5 0.6 9.5 6.5 148 4 151 165 4.6 0 5 4.5 05/04/2006 15:20:00 9 0.5 9.9 7.6 9.1 0.5 10.3 7.6 8.9 0.8 10.3 6.1 149 3 151 165 5 0.1 5.2 4.3 05/04/2006 15:30:00 9.3 0.4 10.3 8 9.4 0.4 10.3 8.4 9.5 0.5 10.3 8 149 3 150 165 5.2 0 5.2 5 05/04/2006 15:40:00 8.6 0.5 9.9 6.8 8.6 0.5 9.9 6.5 8.6 0.7 9.9 6.5 148 4 154 165 4.9 0 5.5 4.5 05/04/2006 15:50:00 8.1 0.5 9.1 6.5 8.1 0.5 9.1 6.8 8 0.6 9.5 6.5 142 5 141 165 4.6 0 5 4.5 05/04/2006 16:00:00 7.9 0.8 9.5 6.1 8 0.8 9.9 5.7 7.8 0.9 9.5 4.9 139 6 126 165 4.4 0 4.8 4 05/04/2006 16:10:00 8.4 0.6 9.9 6.5 8.4 0.6 9.9 6.5 8.3 0.8 9.9 6.1 147 6 151 165 4.4 0.2 4.8 3.8 05/04/2006 16:20:00 8.9 0.4 10.3 7.6 9 0.4 10.3 7.6 8.8 0.6 10.3 6.5 146 4 145 165 4.6 0 4.8 4.5 05/04/2006 16:30:00 9.3 0.5 10.7 7.6 9.3 0.5 11.1 8 9.3 0.5 10.7 7.2 150 4 153 165 4.3 0.1 4.8 3.8 05/04/2006 16:40:00 9.5 0.7 10.7 7.6 9.6 0.7 10.7 7.2 9.3 0.9 10.7 7.2 147 4 153 165 4.2 0 4.8 3.8 05/04/2006 16:50:00 9.8 0.9 11.8 7.6 9.9 0.8 11.8 8 9.7 0.9 11.8 7.6 147 5 148 165 4.2 0.1 4.5 3.8 05/04/2006 17:00:00 10 0.6 11.5 8.4 10 0.6 11.5 8.4 10 0.8 11.8 7.2 147 4 150 165 4 0.1 4.3 3.3 05/04/2006 17:10:00 9.6 0.5 10.7 8 9.6 0.5 10.7 7.6 9.5 0.7 11.1 7.6 147 4 147 165 4 0 4.3 3.5 05/04/2006 17:20:00 10.5 1 12.2 8 10.4 0.9 12.2 8.4 10.4 1.1 12.6 7.6 150 4 153 165 4 0.1 4.3 3.5 05/04/2006 17:30:00 10.8 0.7 13 8.4 10.8 0.7 12.6 8.4 10.9 0.7 13 8.8 154 4 145 165 3.8 0.1 4.3 3.3 05/04/2006 17:40:00 10.4 0.7 11.8 8.4 10.4 0.7 11.8 8.4 10.3 0.7 11.5 8.4 149 3 145 165 3.8 0 4 3.5 05/04/2006 17:50:00 10.2 0.6 11.8 8 10.2 0.6 11.8 8.4 10 0.8 11.8 6.8 145 4 148 165 4 0 4.3 3.5 05/04/2006 18:00:00 9.3 0.8 11.5 7.2 9.2 0.8 11.1 6.8 9.2 0.9 11.1 6.8 157 8 169 165 4 0.1 4.3 3.5 05/04/2006 18:10:00 9.4 0.6 11.1 7.6 9.2 0.6 10.7 7.6 9.5 0.6 11.1 7.6 168 5 172 165 3.7 0.1 4 3.5 05/04/2006 18:20:00 10.9 0.9 12.6 8.8 10.6 0.8 12.2 8.8 11.1 0.9 13 8.8 170 11 177 165 3.5 0 3.8 3.5 05/04/2006 18:30:00 11.7 0.6 13.3 9.9 11.4 0.6 12.6 9.5 11.8 0.7 13.7 9.9 169 7 165 165 3.4 0 3.8 3.3 05/04/2006 18:40:00 11.6 0.7 13.3 9.1 11.3 0.6 12.6 9.1 11.9 0.7 13.7 9.9 169 11 170 165 3.4 0 3.5 3.3 05/04/2006 18:50:00 11.2 0.7 13.3 9.5 10.9 0.7 13 9.1 11.6 0.8 13.3 9.5 168 10 166 165 3.3 0 3.5 3.3 05/04/2006 19:00:00 11.6 0.6 13 9.9 11.3 0.6 12.6 9.9 11.9 0.7 13.3 9.9 169 8 173 165 3.2 0 3.5 3 05/04/2006 19:10:00 10.9 0.8 12.6 8.8 10.6 0.7 12.2 8.8 11.1 0.7 13 9.1 168 12 165 165 3.2 0 3.3 3 05/04/2006 19:20:00 10 0.7 11.8 8.4 9.8 0.6 11.5 8.4 10.3 0.7 11.8 8.4 169 5 166 165 3.2 0 3.3 2.8 05/04/2006 19:30:00 9.7 0.5 11.1 8.4 9.5 0.4 10.3 8.4 10 0.5 11.1 8.4 167 15 165 165 3.1 0 3.3 3 05/04/2006 19:40:00 9.3 0.8 11.1 7.2 9.2 0.9 11.1 7.2 9.5 0.9 11.5 6.8 158 6 145 165 3 0 3.3 2.8 05/04/2006 19:50:00 9.9 0.6 11.8 8.4 10 0.6 11.5 8 10.1 0.8 11.5 7.6 152 3 151 165 2.9 0 3 2.8 05/04/2006 20:00:00 10.6 1.4 14.5 8 10.6 1.3 14.1 8 10.6 1.5 14.1 7.2 150 3 163 165 2.9 0 3 2.8 05/04/2006 20:10:00 12.7 0.8 14.9 10.3 12.7 0.8 14.9 9.9 12.5 1 14.9 9.5 153 6 151 165 2.7 0.1 3 2.3 05/04/2006 20:20:00 12.5 1.2 15.6 9.5 12.6 1.1 15.3 9.9 12.5 1.2 15.6 9.5 151 4 156 165 2.7 0 3 2.3 05/04/2006 20:30:00 13.8 0.7 17.9 12.2 13.9 0.7 17.9 11.5 13.9 0.8 17.2 11.5 152 4 155 165 2.6 0.1 2.8 2.1 05/04/2006 20:40:00 14.5 1.2 17.9 11.1 14.4 1.1 17.9 11.1 14.5 1.3 18.7 10.7 161 6 164 165 2.4 0.2 2.8 1.8 05/04/2006 20:50:00 11.9 1.2 14.9 8.8 11.9 1.2 14.9 8.4 12 1.3 15.3 8 152 9 135 165 2.3 0 2.6 2.1 05/04/2006 21:00:00 12.7 0.7 14.5 10.7 12.7 0.7 14.5 10.7 12.8 0.8 14.5 9.9 151 4 150 165 2.1 0 2.6 1.8 05/04/2006 21:10:00 12.8 0.9 14.9 9.5 12.8 0.8 14.5 9.9 12.8 1 14.9 8.8 148 4 151 165 1.9 0.1 2.3 1.6 05/04/2006 21:20:00 11.6 0.9 13.3 9.1 11.6 0.9 13.3 8.8 11.7 1.1 13.7 8.8 153 5 153 165 2 0 2.3 1.6 05/04/2006 21:30:00 12.2 0.7 14.1 10.3 12.2 0.7 14.1 10.3 12.2 0.8 14.5 9.5 151 4 150 165 2 0 2.3 1.6 05/04/2006 21:40:00 14 0.8 16.1 11.5 14 0.8 15.6 11.5 14 1 16.4 10.7 152 4 152 165 2 0.1 2.3 1.8 05/04/2006 21:50:00 15.1 0.7 16.8 13 15 0.7 16.8 13 15.1 0.8 16.8 12.6 152 4 148 165 1.8 0 2.1 1.6 05/04/2006 22:00:00 14.9 0.6 16.1 12.6 14.7 0.6 16.1 13 15 0.7 16.4 12.6 151 2 148 165 1.6 0.1 2.3 1.4 05/04/2006 22:10:00 14.5 0.7 16.1 12.2 14.3 0.6 15.6 11.8 14.4 0.8 16.1 11.8 151 0 151 165 1.6 0.2 1.8 1.4 05/04/2006 22:20:00 14.3 0.8 16.1 11.5 14.2 0.8 16.1 10.7 14.2 1 16.1 10.3 151 0 151 165 1.6 0.1 1.8 1.4 05/04/2006 22:30:00 14.8 0.9 16.8 11.8 14.6 0.9 16.4 11.8 14.5 1 16.8 11.5 151 0 151 165 1.6 0.2 1.8 1.4 05/04/2006 22:40:00 15.1 0.8 17.2 11.8 14.9 0.8 16.8 11.8 14.8 1.1 16.8 10.7 151 0 151 165 1.7 0.1 1.8 1.4 05/04/2006 22:50:00 15.5 0.8 17.2 12.6 15.2 0.8 16.8 12.2 15.8 1 17.6 10.7 151 0 151 165 1.8 0.1 2.1 1.6 05/04/2006 23:00:00 14.9 1 17.2 11.8 14.8 1.1 17.2 11.5 15.3 1.3 17.9 11.1 151 0 151 165 2 0 2.3 1.8 05/04/2006 23:10:00 16.1 1.1 18.7 13 15.9 1.1 18.3 13 16.3 1.1 18.7 13 150 0 150 165 2.4 0 2.6 2.1 05/04/2006 23:20:00 15.9 1.1 18.7 13 15.6 1 18.3 12.6 15.8 1.2 19.1 12.2 148 3 150 165 2.4 0 2.6 2.3 05/04/2006 23:30:00 16.3 1.1 19.1 13.7 16.1 1 18.7 13.7 16.3 1.3 19.5 12.6 150 4 153 165 2.4 0 2.6 2.3 05/04/2006 23:40:00 14.4 1.1 17.6 11.1 14.4 1.1 17.2 11.5 14.3 1.3 17.2 10.3 144 5 144 165 2.6 0 2.8 2.3 05/04/2006 23:50:00 15 1.1 17.2 11.8 14.9 1 17.2 12.2 14.8 1.3 17.9 11.1 145 5 144 165 2.9 0 3 2.6 05/05/2006 00:00:00 14.4 1.1 16.8 11.5 14.5 1.1 16.8 11.1 14.3 1.4 17.2 9.9 145 5 140 165 3 0.1 3.3 2.8 05/05/2006 00:10:00 14.8 1.1 18.3 11.5 14.9 1.1 18.3 11.5 14.8 1.1 17.9 10.7 144 5 141 165 3.2 0 3.5 2.8 05/05/2006 00:20:00 15.5 1.1 18.7 12.2 15.5 1.2 18.7 11.8 15.3 1.1 18.7 12.2 144 6 145 165 3.5 0.1 3.5 2.8 05/05/2006 00:30:00 15.8 1.2 19.1 12.6 15.9 1.2 18.7 11.8 15.6 1.3 19.1 11.8 142 6 142 165 3.6 0 3.8 3.5 05/05/2006 00:40:00 15.5 1.3 18.7 11.8 15.5 1.3 18.7 12.2 15.2 1.3 19.1 11.5 142 6 146 165 3.9 0 4 3.5 05/05/2006 00:50:00 15 1.3 17.9 10.3 15.1 1.4 17.9 9.9 14.6 1.5 17.6 9.5 142 5 138 165 4 0.1 4.3 3.5 05/05/2006 01:00:00 13.5 1 16.1 10.3 13.6 1 16.4 10.7 13.2 1.1 16.1 9.5 143 6 151 165 4.1 0.2 4.5 3.5 05/05/2006 01:10:00 11.8 1.2 14.5 8.4 11.8 1.2 14.9 8.8 11.3 1.3 13.7 8 144 4 147 165 4.3 0 4.5 3.8 05/05/2006 01:20:00 10.4 0.8 12.2 8.8 10.4 0.8 12.6 8.4 10 0.8 11.8 7.6 143 5 142 165 4.3 0.1 4.5 3.8 05/05/2006 01:30:00 9.5 0.6 11.1 7.6 9.5 0.6 11.1 7.6 9.1 0.7 10.7 6.5 141 4 139 165 4.3 0.1 4.5 3.8 05/05/2006 01:40:00 9 0.5 10.3 8 9.1 0.5 10.7 7.6 8.8 0.6 11.1 6.8 142 4 135 165 4.4 0 4.5 3.8 05/05/2006 01:50:00 8.5 0.7 10.3 6.8 8.6 0.7 9.9 6.8 8.4 0.7 10.3 6.1 145 3 143 165 4.4 0 4.8 4 05/05/2006 02:00:00 7.2 0.5 8.4 6.1 7.2 0.5 8.4 6.1 6.9 0.5 8 5.3 145 5 146 165 4.4 0 4.8 4 05/05/2006 02:10:00 6 0.8 8 3.4 6 0.7 7.6 3.8 5.8 0.8 7.6 4.2 142 6 143 165 4.5 0 4.8 4.3 05/05/2006 02:20:00 5 0.6 6.5 3 5 0.6 6.1 3 5.1 0.6 6.5 3.4 156 10 154 165 4.3 0 4.5 3.8 05/05/2006 02:30:00 5.5 0.5 6.8 4.2 5.4 0.5 6.5 3.8 5.6 0.5 6.8 4.2 153 5 150 165 4.3 0 4.5 3.8 05/05/2006 02:40:00 6.4 1.3 10.3 3.8 6.2 1.2 9.9 3.8 6.4 1.3 10.3 4.2 154 8 154 165 4.3 0 4.5 3.8 05/05/2006 02:50:00 6.6 1.2 9.1 3.8 6.4 1.1 8.8 3.8 6.6 1.1 9.5 4.2 166 9 165 165 4.2 0.1 4.5 3.8 05/05/2006 03:00:00 5.7 1 7.6 3.8 5.5 0.9 7.2 3.4 5.8 0.8 7.6 3.8 167 10 169 165 4.1 0.1 4.3 3.5 05/05/2006 03:10:00 6.6 0.8 8.4 4.6 6.4 0.7 8.8 4.6 6.7 0.9 8.4 4.6 167 8 165 165 4.1 0 4.3 3.8 05/05/2006 03:20:00 5.9 0.8 8 3.8 5.7 0.7 7.6 3.8 5.9 0.7 8 4.2 170 12 160 165 4.1 0 4.5 3.5 05/05/2006 03:30:00 6 1.2 8.4 3.4 5.8 1.1 8 3 6.1 1.1 8.4 3.8 163 12 165 165 4.1 0.1 4.3 3.5 05/05/2006 03:40:00 6 0.9 8.8 3.8 5.8 0.8 8 3.8 6.1 0.7 8 3.8 162 11 180 165 4.1 0.1 4.3 3.5 05/05/2006 03:50:00 5.9 1.1 8.4 3 5.8 1.1 8.8 2.6 6 1 8.8 3.4 165 13 165 165 4.1 0.1 4.3 3.5 05/05/2006 04:00:00 5.2 0.9 8 3.8 5.1 0.8 8 3.4 5.3 0.8 8 3.8 169 12 160 165 4.1 0.1 4.3 3.5 05/05/2006 04:10:00 5.3 0.8 8 3.4 5.2 0.7 7.6 3.4 5.5 0.7 7.2 3.8 168 9 170 165 4.1 0 4.5 3.5 05/05/2006 04:20:00 4.6 0.6 6.5 3 4.5 0.6 6.1 3 4.7 0.6 6.5 3.4 162 7 165 165 4.1 0.1 4.5 3.5 05/05/2006 04:30:00 5.6 1.1 8.8 3 5.6 1 8.4 3 5.7 1 8.8 3 156 11 190 165 4.1 0.1 4.5 3.5 05/05/2006 04:40:00 7 0.6 8.8 5.3 6.9 0.6 8.8 5.3 7.1 0.6 8.8 5.7 153 6 159 165 4.1 0.1 4.5 3.8 05/05/2006 04:50:00 7.2 1.1 10.3 4.2 7.1 1 10.7 4.2 7.4 1.1 11.1 4.9 162 13 148 165 4.2 0 4.5 3.8 05/05/2006 05:00:00 7 1.2 10.3 4.9 6.9 1.1 10.3 4.6 7.1 1.1 10.3 4.9 172 13 182 165 4.2 0 4.5 3.8 05/05/2006 05:10:00 8.6 1.3 12.6 5.7 8.4 1.2 12.2 5.7 8.7 1.2 12.2 6.8 169 11 179 165 4.1 0 4.5 3.5 05/05/2006 05:20:00 10.2 1.2 14.1 7.2 9.8 1.2 13.3 7.2 10.2 1.2 13.7 7.6 174 8 181 165 4.1 0.1 4.5 3.5 05/05/2006 05:30:00 10.2 0.8 12.2 7.6 9.9 0.8 12.2 7.6 10.1 0.9 12.6 8 169 7 180 165 4 0.1 4.3 3.5 05/05/2006 05:40:00 10.5 0.6 12.2 8.8 10.3 0.6 11.8 8.8 10.6 0.6 11.8 9.1 169 4 167 165 4.1 0.1 4.3 3.5 05/05/2006 05:50:00 10.8 0.9 13.7 8 10.5 0.8 13 8 11 1 13.3 8.4 170 5 166 165 4.1 0.1 4.3 3.5 05/05/2006 06:00:00 9 0.7 10.7 7.2 8.7 0.6 10.3 6.8 9.1 0.7 10.7 7.2 171 5 171 165 4.1 0.1 4.3 3.5 05/05/2006 06:10:00 8.4 1.2 11.1 5.7 8.2 1.1 10.7 5.7 8.6 1.2 11.5 6.1 169 9 164 165 4 0.1 4.3 3.5 05/05/2006 06:20:00 10.6 0.7 12.2 8.4 10.2 0.6 12.2 8 10.7 0.7 12.2 8.4 169 7 164 165 4 0 4.3 3.5 05/05/2006 06:30:00 8.5 1 10.3 5.7 8.2 0.9 9.9 5.7 8.6 1 10.3 6.1 173 6 170 165 3.9 0 4.3 3.5 05/05/2006 06:40:00 9.5 1 11.8 6.5 9.2 1 11.1 6.8 9.5 1 11.5 6.5 170 9 155 165 3.9 0 4 3.3 05/05/2006 06:50:00 10.2 0.6 11.8 8.8 10 0.6 11.5 8.8 10.3 0.7 12.2 8.4 168 17 171 165 3.8 0 4 3 05/05/2006 07:00:00 10.6 0.7 12.2 8.8 10.2 0.7 11.8 8.8 10.7 0.8 12.6 9.1 171 11 176 165 3.7 0.1 3.8 3.5 05/05/2006 07:10:00 10.1 0.7 11.8 8 9.7 0.7 11.5 7.6 10.3 0.7 12.2 8 171 5 174 165 3.7 0.1 3.8 3 05/05/2006 07:20:00 10.6 1 12.6 8.4 10.3 1 12.2 8.4 10.8 1 13 8.8 169 5 167 165 3.7 0 3.8 3 05/05/2006 07:30:00 11.6 0.9 13.3 9.1 11.2 0.8 13 8.8 11.8 1 13.7 9.1 171 11 174 165 3.6 0 3.8 3.5 05/05/2006 07:40:00 10 0.8 11.8 7.6 9.7 0.8 11.5 7.2 10.3 0.9 11.8 8 172 8 175 165 3.6 0 3.8 3.5 05/05/2006 07:50:00 8.4 0.6 9.9 6.5 8.1 0.6 9.9 6.5 8.7 0.7 9.9 6.8 170 5 165 165 3.7 0 4 3.5 05/05/2006 08:00:00 9.1 0.9 11.1 6.8 8.8 0.8 10.7 6.5 9.3 0.8 11.1 7.6 169 12 169 165 3.7 0 3.8 3.5 05/05/2006 08:10:00 10.2 0.5 11.5 8.4 9.9 0.5 11.1 8.4 10.5 0.6 11.8 8.8 169 5 171 165 3.8 0 4 3.5 05/05/2006 08:20:00 10.6 0.7 12.2 8.8 10.3 0.7 11.8 8.4 10.8 0.7 12.2 9.1 168 4 165 165 3.7 0 4 3.5 05/05/2006 08:30:00 11.2 0.7 12.6 9.1 10.8 0.6 12.6 9.1 11.2 0.8 13 9.1 167 8 165 165 3.6 0 3.8 3.5 05/05/2006 08:40:00 11 0.5 12.2 9.5 10.7 0.5 11.8 9.5 11.2 0.6 12.6 9.5 165 17 165 165 3.6 0 3.8 3.5 05/05/2006 08:50:00 10.2 0.8 11.8 8 9.9 0.7 11.5 8 10.5 0.8 12.2 8 168 8 165 165 3.9 0 4.3 3.5 05/05/2006 09:00:00 8.4 0.7 9.9 6.8 8.2 0.6 9.5 6.5 8.6 0.8 9.9 6.5 167 10 165 165 4.1 0.1 4.5 3.8 05/05/2006 09:10:00 8.3 0.7 9.9 6.5 8.1 0.6 9.5 6.5 8.5 0.7 10.3 6.5 171 5 166 165 3.8 0 4.3 3.5 05/05/2006 09:20:00 6.6 0.6 8 5.3 6.3 0.6 8 4.9 6.9 0.6 8.4 5.3 172 8 177 165 3.9 0 4.3 3.3 05/05/2006 09:30:00 6.4 0.5 7.6 5.3 6.2 0.4 7.2 5.3 6.7 0.5 8 5.3 170 5 170 165 4 0.2 4.3 3.5 05/05/2006 09:40:00 6.3 0.5 7.2 4.9 6.1 0.5 6.8 4.9 6.5 0.5 7.6 5.3 167 8 165 165 3.9 0 4.3 3.8 05/05/2006 09:50:00 6.8 0.5 8.4 5.3 6.5 0.5 8 4.9 7 0.6 8.8 5.7 164 4 157 165 4 0.1 4.3 3.5 05/05/2006 10:00:00 7.9 0.5 9.1 6.8 7.7 0.5 8.8 6.8 8.1 0.5 9.5 6.8 167 13 167 165 4.2 0.1 4.5 3.8 05/05/2006 10:10:00 8.5 0.9 10.7 6.8 8.3 0.9 10.3 6.8 8.8 1 10.7 7.2 166 12 163 165 4.1 0.2 4.5 3.5 05/05/2006 10:20:00 9.8 0.4 10.7 8.4 9.5 0.4 10.7 8.4 10.1 0.5 11.5 8.4 166 8 162 165 4 0.2 4.3 3.5 05/05/2006 10:30:00 8.9 0.5 9.9 7.2 8.7 0.5 9.9 7.2 9.2 0.6 10.3 6.8 163 14 165 165 4.1 0.1 4.3 3.5 05/05/2006 10:40:00 8.4 0.8 9.9 6.1 8.3 0.8 9.5 6.1 8.6 0.9 10.3 6.1 163 9 163 165 4.3 0.1 4.8 3.8 05/05/2006 10:50:00 7.4 1.5 10.7 4.2 7.5 1.5 10.3 4.6 7.5 1.7 11.1 4.6 160 13 163 165 4.6 0.1 5 4.3 05/05/2006 11:00:00 9.5 0.7 10.7 7.2 9.3 0.6 10.3 7.2 9.9 0.7 11.5 7.6 168 13 170 165 4.3 0.2 4.8 3.8 05/05/2006 11:10:00 6.6 0.8 8.4 4.6 6.5 0.8 8.4 4.6 6.9 0.9 8.8 4.9 173 13 180 165 4.7 0.1 5 4 05/05/2006 11:20:00 6.7 1.1 10.3 4.6 6.5 1.1 10.3 4.6 6.8 1 10.3 4.9 174 8 189 165 4.6 0 4.8 4.5 05/05/2006 11:30:00 7.1 0.8 8.8 4.9 7 0.8 8.4 4.9 7.3 0.9 9.5 4.9 168 10 165 165 4.8 0 5 4.5 05/05/2006 11:40:00 9.6 0.6 11.5 7.6 9.3 0.6 11.1 7.2 9.8 0.8 11.8 8 165 7 234 165 4.4 0.1 5 3.8 05/05/2006 11:50:00 9.7 0.6 11.1 8 9.5 0.6 10.7 8 10 0.6 11.5 8.4 164 13 165 165 4.6 0.1 5 4 05/05/2006 12:00:00 9.8 0.7 11.5 8 9.6 0.7 11.1 7.6 10 0.8 11.8 8 162 8 164 165 4.5 0 4.8 4.3 05/05/2006 12:10:00 10.3 0.6 11.8 8.4 10 0.6 11.8 8.4 10.5 0.5 12.2 8.8 165 7 161 165 4.4 0.2 4.8 3.8 05/05/2006 12:20:00 10.1 0.6 11.5 8.4 9.9 0.6 11.5 8.4 10.3 0.6 11.5 8.4 164 11 165 165 4.9 0.2 5.2 4.3 05/05/2006 12:30:00 8.8 0.7 10.3 6.8 8.7 0.6 10.3 7.2 9 0.7 10.7 6.8 160 12 163 165 4.8 0.1 5.2 4.5 05/05/2006 12:40:00 8.2 0.7 9.9 6.5 8.1 0.7 10.3 6.5 8.3 0.7 10.3 6.1 158 12 165 165 4.8 0 5.2 4.5 05/05/2006 12:50:00 8.4 0.7 10.3 6.8 8.1 0.6 9.9 6.8 8.6 0.7 10.3 6.5 161 15 160 165 4.9 0 5.2 4.8 05/05/2006 13:00:00 9.2 0.6 10.7 8 8.9 0.6 10.3 7.6 9.5 0.6 11.1 7.6 164 4 164 165 5.3 0 5.7 5 05/05/2006 13:10:00 9.5 0.6 10.7 7.6 9.3 0.5 10.3 8 9.8 0.7 11.5 7.2 165 7 158 165 5.2 0.1 5.5 4.8 05/05/2006 13:20:00 8.7 0.6 9.9 7.2 8.5 0.6 9.9 6.8 9 0.6 10.3 7.2 164 10 164 165 5.7 0.3 6.2 5 05/05/2006 13:30:00 8.6 0.9 10.3 6.1 8.4 0.8 9.9 6.1 8.8 1 11.1 6.1 163 9 165 165 5.5 0.2 5.7 5.2 05/05/2006 13:40:00 8.7 0.6 10.3 7.2 8.5 0.6 10.3 7.2 9 0.6 10.7 7.6 166 4 173 165 5.6 0.2 6 5 05/05/2006 13:50:00 7.1 0.9 8.8 4.6 6.9 0.8 8.8 4.9 7.3 0.9 9.1 5.3 165 18 166 165 5.6 0 5.7 5.5 05/05/2006 14:00:00 7.2 0.4 8 5.7 7 0.4 8 5.7 7.5 0.4 8.4 6.5 167 6 166 165 5.7 0 6 5.5 05/05/2006 14:10:00 7.6 0.6 8.8 5.7 7.4 0.5 8.4 5.7 7.9 0.7 9.1 6.1 167 3 165 165 5.7 0.1 6.2 5.5 05/05/2006 14:20:00 7.4 0.7 8.8 5.7 7.3 0.6 8.4 5.7 7.6 0.7 9.1 6.1 165 9 165 165 5.7 0.1 6 5.5 05/05/2006 14:30:00 7.8 0.5 8.8 6.5 7.6 0.4 8.8 6.1 8 0.5 9.1 6.5 166 8 165 165 5.9 0.2 6.2 5.5 05/05/2006 14:40:00 8.2 0.5 9.1 6.5 8 0.5 9.1 6.5 8.5 0.6 9.9 6.5 166 13 164 165 5.7 0 6 5.5 05/05/2006 14:50:00 7.3 0.5 8.8 6.1 7.1 0.5 8.4 5.3 7.5 0.5 8.8 6.1 167 6 168 165 6.1 0.3 6.7 5.5 05/05/2006 15:00:00 7.5 0.4 8.4 6.1 7.3 0.4 8 6.1 7.7 0.5 8.8 6.5 167 4 171 165 6.3 0.1 6.7 6 05/05/2006 15:10:00 7.4 0.4 8.8 5.7 7.3 0.4 8.4 5.7 7.7 0.5 9.1 6.5 166 6 163 165 6.1 0 6.2 5.7 05/05/2006 15:20:00 7.6 0.5 9.1 5.7 7.5 0.4 8.8 6.1 7.8 0.5 8.8 6.5 160 13 164 165 6 0 6.2 5.7 05/05/2006 15:30:00 6.9 0.6 8.4 5.3 6.9 0.6 8.4 5.3 7 0.6 8.4 5.7 147 5 150 165 5.7 0 5.7 5.5 05/05/2006 15:40:00 6.4 0.4 7.2 5.3 6.4 0.4 7.6 5.7 6.6 0.4 7.6 5.3 145 4 142 165 5.6 0.1 5.7 5.5 05/05/2006 15:50:00 6.6 0.4 7.6 5.3 6.7 0.4 7.6 5.7 6.8 0.4 8 5.7 144 5 142 165 5.8 0.1 6 5.7 05/05/2006 16:00:00 7.2 0.6 8.8 5.7 7.3 0.6 8.4 5.7 7.4 0.7 8.8 5.3 145 4 145 165 5.5 0 5.7 5.2 05/05/2006 16:10:00 8.3 0.5 9.5 6.8 8.3 0.5 9.5 6.8 8.3 0.5 9.1 6.5 145 4 143 165 4.9 0.1 5.2 4.5 05/05/2006 16:20:00 8.2 0.5 9.5 6.8 8.2 0.5 9.1 6.5 8.2 0.5 9.5 6.5 144 4 143 165 4.7 0 5 4.5 05/05/2006 16:30:00 7.6 0.4 8.4 6.5 7.7 0.4 8.4 6.5 7.7 0.5 8.8 6.5 144 3 145 165 4.6 0 4.8 4.5 05/05/2006 16:40:00 6.8 0.5 8 5.7 6.8 0.5 7.6 5.3 6.7 0.6 8 4.9 139 6 158 165 4.5 0 4.8 4.3 05/05/2006 16:50:00 6 0.4 6.8 4.6 6.1 0.4 6.8 4.9 6 0.4 6.8 4.6 139 4 138 165 4.6 0.1 4.8 4.3 05/05/2006 17:00:00 6 0.4 6.8 4.9 6.1 0.4 7.2 4.9 6 0.4 7.2 4.6 137 4 140 165 4.8 0.1 5 4.5 05/05/2006 17:10:00 5.5 0.5 6.5 4.2 5.6 0.5 6.8 4.2 5.5 0.6 6.8 4.2 135 6 136 165 4.8 0 5 4.8 05/05/2006 17:20:00 5.3 0.5 6.5 3.8 5.4 0.5 6.5 3.8 5.3 0.5 6.8 3.8 134 6 138 165 4.9 0 5 4.8 05/05/2006 17:30:00 5.8 0.6 7.2 4.2 6 0.6 7.2 4.6 5.7 0.6 7.2 4.2 134 5 136 165 4.8 0 5.5 4.8 05/05/2006 17:40:00 5.3 0.5 7.2 4.2 5.5 0.5 7.2 4.2 5.3 0.5 6.8 4.2 132 7 143 165 4.8 0 5 4.8 05/05/2006 17:50:00 5.1 0.4 6.1 3.8 5.2 0.4 6.1 3.8 5.1 0.4 6.1 3.4 138 6 138 165 4.9 0 5 4.8 05/05/2006 18:00:00 4.3 0.6 5.7 3 4.4 0.6 5.7 3 4.3 0.6 5.7 2.6 135 10 147 165 5.2 0.1 5.5 4.8 05/05/2006 18:10:00 4.9 0.6 6.5 3.8 5 0.6 6.8 3.4 5 0.6 6.8 3.4 132 7 130 165 5.2 0.1 5.5 5 05/05/2006 18:20:00 5.8 0.5 7.2 4.6 5.9 0.5 7.2 4.2 5.8 0.6 7.2 4.2 136 7 141 165 5 0 5.5 4.5 05/05/2006 18:30:00 7.4 0.8 9.1 5.7 7.4 0.7 8.8 5.7 7.6 0.8 9.1 5.7 145 5 148 165 4.3 0.2 4.8 3.8 05/05/2006 18:40:00 7.4 0.5 8.8 6.1 7.4 0.5 8.8 6.1 7.4 0.5 9.1 6.5 146 3 151 165 4.1 0.2 4.5 3.5 05/05/2006 18:50:00 6.7 0.4 8 5.3 6.6 0.4 7.6 5.3 6.8 0.4 8 5.7 152 4 158 165 4.1 0.1 4.3 3.5 05/05/2006 19:00:00 6.2 0.4 7.2 4.9 6.2 0.3 7.2 5.3 6.3 0.4 7.2 5.3 151 3 156 165 4 0.1 4.3 3.5 05/05/2006 19:10:00 6.3 0.4 6.8 4.9 6.3 0.4 7.2 5.3 6.4 0.4 7.2 4.9 143 4 145 165 3.8 0 4 3.5 05/05/2006 19:20:00 6.1 0.4 7.2 4.9 6.2 0.4 7.2 4.9 6.2 0.5 7.2 4.2 139 3 135 165 3.7 0 4 3.5 05/05/2006 19:30:00 5.1 0.5 6.1 3.8 5.2 0.5 6.5 3.8 5.1 0.6 6.5 3.4 139 5 143 165 3.8 0 4 3.3 05/05/2006 19:40:00 5.1 0.5 6.1 3.4 5.1 0.5 6.1 3 5.1 0.5 6.1 3.8 140 6 140 165 3.8 0 4 3.3 05/05/2006 19:50:00 5.7 0.5 6.5 4.2 5.7 0.5 6.5 3.8 5.6 0.6 6.8 4.2 141 5 129 165 3.8 0 4 3.3 05/05/2006 20:00:00 5.9 0.3 6.8 4.9 6 0.3 6.8 5.3 6.1 0.4 6.8 5.3 144 4 145 165 3.8 0 4 3.3 05/05/2006 20:10:00 6.1 0.3 6.8 4.9 6.1 0.3 6.8 4.9 6.3 0.4 6.8 4.9 150 3 150 165 3.8 0 4 3 05/05/2006 20:20:00 5.7 0.4 6.5 4.2 5.6 0.4 6.5 4.6 5.8 0.4 6.8 4.6 152 2 156 165 3.6 0 3.8 3.5 05/05/2006 20:30:00 5.4 0.4 6.5 4.2 5.3 0.4 6.1 4.2 5.5 0.5 6.8 4.2 152 4 157 165 3.6 0 3.8 3.5 05/05/2006 20:40:00 5.7 0.4 6.5 4.6 5.7 0.4 6.5 4.6 5.9 0.4 6.8 4.6 156 4 153 165 3.6 0 3.8 3.3 05/05/2006 20:50:00 5.4 0.5 7.2 4.2 5.4 0.5 6.8 4.2 5.5 0.6 7.6 4.2 158 6 152 165 3.6 0 3.8 3.3 05/05/2006 21:00:00 5 0.5 6.1 3.4 4.9 0.5 6.1 3.8 5.2 0.5 6.8 3.4 157 6 163 165 3.5 0.1 3.8 3 05/05/2006 21:10:00 4.8 0.4 6.1 3.4 4.7 0.4 5.7 3.4 4.9 0.5 6.1 3.4 163 8 164 165 3.5 0 3.5 3 05/05/2006 21:20:00 5.1 0.4 6.1 3.8 5 0.3 5.7 3.8 5.3 0.4 6.1 4.2 166 6 165 165 3.5 0 3.5 3.3 05/05/2006 21:30:00 5.2 0.3 6.1 4.6 5 0.3 5.7 4.2 5.4 0.4 6.1 4.6 165 4 165 165 3.4 0 3.5 3.3 05/05/2006 21:40:00 5 0.3 5.7 4.2 4.9 0.3 5.3 4.2 5.3 0.3 6.1 4.6 164 15 162 165 3.3 0 3.5 3.3 05/05/2006 21:50:00 4.7 0.4 5.7 3.4 4.6 0.4 5.7 3.4 4.9 0.4 6.1 3.8 162 10 150 165 3.3 0 3.5 3.3 05/05/2006 22:00:00 5.7 0.4 6.8 4.2 5.6 0.4 6.8 4.6 6 0.5 6.8 4.6 155 4 151 165 3.3 0 3.5 3 05/05/2006 22:10:00 5.4 0.4 6.1 4.2 5.3 0.4 6.1 4.2 5.6 0.4 6.5 4.6 155 3 151 165 3.3 0 3.5 3 05/05/2006 22:20:00 4.8 0.4 6.1 3.8 4.8 0.4 6.1 3.8 5.2 0.4 6.1 4.2 156 5 147 165 3.2 0 3.5 3 05/05/2006 22:30:00 5.1 0.3 5.7 4.2 5 0.3 5.7 4.2 5.3 0.3 6.1 4.6 155 9 154 165 3 0 3.3 2.8 05/05/2006 22:40:00 4.7 0.4 5.3 3.8 4.6 0.3 5.3 3.8 4.9 0.3 5.7 4.2 156 3 157 165 3 0 3.3 2.8 05/05/2006 22:50:00 4.1 0.2 4.6 3.4 4.1 0.2 4.6 3.4 4.5 0.2 4.9 3.8 156 3 152 165 3 0 3.3 2.8 05/05/2006 23:00:00 3.5 0.3 4.2 2.6 3.5 0.3 4.2 2.6 3.8 0.3 4.6 3 156 3 164 165 3 0 3.3 2.8 05/05/2006 23:10:00 3.2 0.3 3.8 2.6 3.2 0.3 3.8 2.6 3.5 0.3 4.2 2.6 149 8 152 165 3 0.1 3.3 2.6 05/05/2006 23:20:00 3.1 0.3 3.8 2.6 3.1 0.3 3.8 2.6 3.3 0.3 4.2 2.6 149 4 142 165 3 0.1 3.3 2.8 05/05/2006 23:30:00 2.6 0.3 3.4 1.9 2.8 0.3 3.4 2.3 3 0.3 3.8 2.3 149 4 149 165 2.9 0.1 3.3 2.6 05/05/2006 23:40:00 1.7 0.6 3 0.4 1.8 0.6 3 0.4 2.1 0.6 3.4 0.7 145 15 156 165 2.9 0.1 3.3 2.6 05/05/2006 23:50:00 1.5 0.4 2.6 0.4 1.6 0.4 2.6 0.4 1.9 0.3 2.6 1.1 124 5 114 165 2.9 0.1 3.3 2.6 05/06/2006 00:00:00 1.4 0.4 2.3 0.7 1.4 0.4 2.6 0.7 1.7 0.4 2.6 1.1 120 3 114 165 2.9 0.1 3.3 2.8 05/06/2006 00:10:00 0.4 0.1 1.1 0.4 0.4 0.1 1.1 0.4 0.9 0.3 1.5 0.4 119 0 119 165 2.9 0.1 3.3 2.6 05/06/2006 00:20:00 1.1 0.6 1.9 0.4 1.1 0.6 1.9 0.4 1.5 0.4 2.3 0.4 90 19 84 165 2.9 0.2 3 2.6 05/06/2006 00:30:00 1 0.2 1.5 0.7 1 0.3 1.9 0.4 1.4 0.2 1.9 0.7 76 3 73 165 2.7 0.2 3 2.3 05/06/2006 00:40:00 1.3 0.2 1.9 0.7 1.3 0.3 1.9 0.4 1.6 0.4 1.9 0.4 82 2 82 165 2.6 0.1 2.8 2.3 05/06/2006 00:50:00 0.6 0.3 1.5 0.4 0.4 0.1 1.1 0.4 1 0.3 1.5 0.4 20 14 21 165 2.6 0.1 2.8 2.3 05/06/2006 01:00:00 0.5 0.3 1.5 0.4 0.4 0.1 1.1 0.4 0.9 0.2 1.5 0.4 41 5 43 165 2.6 0.1 3 2.3 05/06/2006 01:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.8 0.3 1.5 0.4 34 10 165 165 2.6 0.1 2.8 2.1 05/06/2006 01:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.7 0.3 1.5 0.4 21 0 165 165 2.7 0 2.8 2.3 05/06/2006 01:30:00 1.6 0.7 2.6 0.4 0.8 0.5 2.3 0.4 1.8 0.5 3 0.4 6 6 5 165 2.7 0 2.8 2.3 05/06/2006 01:40:00 2.3 0.4 3 1.5 1.7 0.5 3 0.4 2.5 0.3 3.4 1.5 13 9 355 165 2.7 0 2.8 2.3 05/06/2006 01:50:00 2.3 0.3 3 1.5 2.1 0.3 3 1.1 2.6 0.2 3 1.9 22 6 23 165 2.4 0.1 2.8 2.3 05/06/2006 02:00:00 2.3 0.3 3 1.5 2.4 0.3 3 1.5 2.6 0.2 3 2.3 28 3 28 165 2.2 0 2.6 1.8 05/06/2006 02:10:00 1.5 0.3 2.3 0.7 1.1 0.4 1.9 0.4 1.8 0.3 2.6 1.1 21 4 26 165 2.2 0.1 2.3 1.6 05/06/2006 02:20:00 2.1 0.2 2.6 1.5 1 0.4 2.3 0.4 2.3 0.2 3 1.9 7 4 6 165 2.2 0.1 2.3 1.8 05/06/2006 02:30:00 2.4 0.3 3.4 1.9 1.1 0.5 2.6 0.4 2.6 0.3 3.4 1.9 355 3 350 165 2.3 0.1 2.6 1.8 05/06/2006 02:40:00 3.1 0.3 3.8 2.3 2.2 0.8 3.8 0.7 3.3 0.3 4.2 2.3 353 6 2 165 2.1 0.2 2.3 1.4 05/06/2006 02:50:00 3.4 0.2 3.8 2.6 2.3 0.6 3.8 1.1 3.2 0.4 3.8 1.9 347 1 344 165 1.7 0.1 1.8 1.4 05/06/2006 03:00:00 3.3 0.3 4.2 2.6 2.2 0.8 3.8 0.7 2.8 0.4 3.8 1.9 348 0 349 165 1.6 0.1 1.8 1.1 05/06/2006 03:10:00 3.1 0.3 3.8 2.6 1.7 0.6 3.4 0.7 3.2 0.3 3.8 2.6 349 0 349 165 1.5 0.1 1.8 1.1 05/06/2006 03:20:00 3 0.2 3.8 2.3 1.3 0.6 3 0.4 3.3 0.3 4.2 2.6 349 0 349 165 1.6 0 1.8 1.1 05/06/2006 03:30:00 3.1 0.3 3.8 2.6 1.7 0.6 3 0.4 3.6 0.2 4.2 3 350 0 350 165 1.5 0.1 1.6 0.9 05/06/2006 03:40:00 2.8 0.2 3.4 2.3 0.4 0.3 2.3 0.4 3.3 0.2 4.2 3 350 0 350 165 1.5 0.1 1.8 0.9 05/06/2006 03:50:00 2.2 0.2 3 1.5 0.4 0 0.4 0.4 2.6 0.3 3.4 1.9 350 0 350 165 1.7 0.2 1.8 1.4 05/06/2006 04:00:00 1.9 0.2 2.3 1.5 0.4 0 0.4 0.4 2.3 0.2 2.6 1.9 350 0 350 165 1.7 0.1 1.8 1.4 05/06/2006 04:10:00 2.3 0.2 3 1.9 0.4 0 0.4 0.4 2.6 0.2 3.4 2.3 350 0 350 165 1.7 0 1.8 1.4 05/06/2006 04:20:00 2.4 0.2 3 1.9 0.4 0 0.4 0.4 2.7 0.2 3.4 2.3 350 0 350 165 1.7 0 1.8 1.4 05/06/2006 04:30:00 1.9 0.3 2.6 1.5 0.4 0 0.4 0.4 2.2 0.3 3 1.5 350 0 350 165 1.8 0.1 2.1 1.4 05/06/2006 04:40:00 2.1 0.5 3.4 1.5 0.4 0 0.4 0.4 2.3 0.4 3.8 1.9 350 0 351 165 1.8 0.1 2.1 1.4 05/06/2006 04:50:00 2.9 0.3 3.8 2.3 0.4 0 0.4 0.4 2.9 0.3 3.8 2.3 351 0 351 165 1.9 0.1 2.1 1.4 05/06/2006 05:00:00 2.7 0.2 3.4 2.3 0.4 0 0.4 0.4 2.9 0.2 3.4 2.3 351 0 352 165 1.9 0.1 2.1 1.4 05/06/2006 05:10:00 2.9 0.2 3.4 2.3 0.4 0 0.4 0.4 3 0.2 3.4 2.6 352 0 352 165 1.9 0.1 2.1 1.4 05/06/2006 05:20:00 2.5 0.2 3 1.9 0.4 0 0.4 0.4 2.8 0.2 3.4 2.3 352 0 353 165 1.8 0.1 1.8 1.4 05/06/2006 05:30:00 2.8 0.3 3.4 2.3 0.4 0 0.4 0.4 3.1 0.3 3.8 2.3 352 0 353 165 1.8 0.2 2.1 1.4 05/06/2006 05:40:00 2.7 0.2 3.4 2.3 0.4 0 0.4 0.4 3 0.2 3.4 2.3 353 0 353 165 1.8 0.1 2.1 1.4 05/06/2006 05:50:00 3.3 0.4 4.2 2.3 0.6 0.4 2.3 0.4 3.4 0.4 4.6 2.3 354 0 354 165 1.9 0.1 2.1 1.4 05/06/2006 06:00:00 3.5 0.3 4.2 2.6 1.8 0.8 3.8 0.7 3.7 0.3 4.2 3 352 3 354 165 1.9 0.1 2.1 1.4 05/06/2006 06:10:00 3.8 0.2 4.2 3 2.4 0.7 4.2 0.7 4.1 0.3 4.6 3.4 350 5 354 165 2 0.1 2.1 1.4 05/06/2006 06:20:00 4.2 0.4 5.3 3 2.9 0.7 4.9 1.5 4.3 0.3 4.9 3.4 349 3 344 165 2 0 2.3 1.4 05/06/2006 06:30:00 4.2 0.3 4.9 3.4 2.5 0.7 4.6 1.1 4.4 0.3 4.9 3.8 353 4 356 165 2 0.1 2.3 1.4 05/06/2006 06:40:00 4.2 0.3 4.9 3.4 2.1 0.5 3.4 1.1 4.6 0.3 5.3 3.8 356 3 358 165 2.1 0.1 2.3 1.6 05/06/2006 06:50:00 4.4 0.3 4.9 3.4 3.1 0.8 4.9 1.5 4.6 0.3 5.3 4.2 351 4 351 165 2.2 0.1 2.6 1.8 05/06/2006 07:00:00 4.3 0.3 4.9 3.8 2.6 0.6 4.2 1.1 4.6 0.3 5.3 3.8 355 4 353 165 2.4 0.1 2.6 1.8 05/06/2006 07:10:00 4.2 0.3 4.9 3.4 2.6 0.6 4.2 1.5 4.3 0.4 4.9 3.4 3 6 360 165 2.4 0.1 2.6 1.8 05/06/2006 07:20:00 4 0.4 4.9 3 2.5 0.5 4.2 1.1 4.2 0.4 4.9 2.6 3 4 359 165 2.7 0.2 3.3 1.8 05/06/2006 07:30:00 3.6 0.4 4.6 2.6 2.8 1.1 4.9 1.1 3.8 0.4 4.9 2.3 357 9 358 165 3 0.1 3.3 2.6 05/06/2006 07:40:00 3.9 0.4 4.9 2.6 4.3 0.8 5.7 1.9 4 0.4 4.9 3 345 6 349 165 3 0.1 3.3 2.6 05/06/2006 07:50:00 3.6 0.5 4.9 2.3 3.7 0.8 5.3 1.9 3.9 0.4 5.3 2.6 347 9 358 165 3 0.1 3.3 2.6 05/06/2006 08:00:00 3.3 0.7 4.9 1.9 3 0.9 4.9 0.7 3.4 0.6 5.7 1.9 348 11 354 165 3 0.2 3.3 2.6 05/06/2006 08:10:00 2.9 0.8 4.6 1.1 2.4 0.9 4.9 0.7 3 0.8 4.9 1.1 349 14 340 165 3.2 0.2 3.5 2.6 05/06/2006 08:20:00 2.1 0.5 3.8 0.7 1.9 0.6 4.2 0.4 2.1 0.4 3 1.1 333 14 319 165 3.2 0.1 3.5 2.8 05/06/2006 08:30:00 2.5 0.4 4.2 1.5 2.6 0.4 4.2 1.1 2.4 0.4 3.4 1.5 329 10 332 165 3.2 0.1 3.5 2.8 05/06/2006 08:40:00 2.1 0.5 3.4 1.1 2.1 0.5 3.4 1.1 2.1 0.5 3 0.7 337 10 358 165 3.5 0.1 3.8 3 05/06/2006 08:50:00 2.4 0.6 4.6 1.1 2.2 0.6 4.2 1.1 2.4 0.7 4.2 0.7 341 13 359 165 3.8 0.2 4.3 3 05/06/2006 09:00:00 3.5 1 5.7 1.1 3.4 1 5.7 0.7 3.3 0.9 5.3 1.1 335 15 348 165 4.3 0.1 4.8 4 05/06/2006 09:10:00 2.4 0.7 4.6 0.4 2.5 0.7 4.6 0.4 2.2 0.7 4.2 0.4 310 15 307 165 4.2 0.2 4.5 3.5 05/06/2006 09:20:00 3.2 0.8 4.9 0.7 3.3 0.8 5.3 0.7 2.7 0.8 4.9 0.4 301 10 303 165 3.7 0.1 4 3.3 05/06/2006 09:30:00 4.7 0.8 6.5 3 4.7 0.7 6.5 3 3.8 0.7 5.3 2.3 300 7 296 165 3.6 0 3.8 3 05/06/2006 09:40:00 5.3 0.6 6.8 3.8 5.3 0.6 6.5 3.4 4.5 0.7 6.1 2.6 307 6 307 165 4 0.1 4.5 3.5 05/06/2006 09:50:00 5.6 0.7 8.4 4.2 5.6 0.7 8 4.2 4.7 0.7 7.6 2.6 305 10 299 165 4.6 0.2 5 3.8 05/06/2006 10:00:00 6 0.6 7.2 4.2 6 0.6 7.2 4.2 5 0.9 7.6 3 303 8 309 165 4.4 0 4.5 4.3 05/06/2006 10:10:00 5.9 0.9 8 3 5.9 0.9 8 3 4.9 1 8 3 295 9 286 165 4.5 0 4.8 4.3 05/06/2006 10:20:00 6.2 1.3 9.1 2.6 6.2 1.3 8.8 2.3 5.2 1.3 8.8 2.3 293 10 295 165 4.3 0 4.5 4.3 05/06/2006 10:30:00 6.5 0.9 9.1 4.2 6.4 0.9 8.8 3.8 5.4 0.8 7.6 3.4 304 10 293 165 4.3 0 4.8 4 05/06/2006 10:40:00 4.9 0.9 7.6 2.3 4.8 0.9 8 2.3 4.5 1 7.6 1.9 309 11 309 165 4.6 0.2 5 4.3 05/06/2006 10:50:00 6.3 1 8.4 3.8 6.3 0.9 8.8 3.8 6.2 0.8 8.4 4.2 336 8 339 165 4.8 0 5 4.5 05/06/2006 11:00:00 6.3 1.3 9.9 3 6 1.2 10.3 3 6.3 1.4 9.9 2.6 344 10 357 165 5.3 0 5.5 5 05/06/2006 11:10:00 6.2 0.8 8.4 4.2 5.7 1.2 8.8 2.6 6.1 0.7 8.4 4.6 346 8 344 165 5.7 0.2 6.2 5 05/06/2006 11:20:00 6.1 1 8.4 3.8 5.9 1 8.4 2.6 6.2 1 8.8 3.8 347 6 351 165 5.9 0.1 6 5.7 05/06/2006 11:30:00 6.9 1.1 9.9 3.8 6.4 1.5 10.3 3 6.8 1.1 9.1 3.8 346 13 339 165 5.9 0.2 6.7 5.7 05/06/2006 11:40:00 6.9 1.1 9.5 3.8 6.3 1.5 9.5 2.6 6.8 1.1 9.1 3.8 348 10 335 165 6.2 0.2 6.7 6 05/06/2006 11:50:00 6.4 0.8 8.8 4.2 6 1.1 8.4 3.4 6.4 1 9.1 4.6 344 10 356 165 5.8 0.1 6.2 5.7 05/06/2006 12:00:00 5.9 1 8.4 3 5.4 1.3 9.1 2.3 5.7 1.1 8.4 2.3 347 11 351 165 6.2 0.2 6.7 5.7 05/06/2006 12:10:00 5.7 1.4 9.5 2.6 5.4 1.5 9.5 2.6 5.3 1.5 9.1 2.6 344 14 336 165 6.7 0.2 7 6.2 05/06/2006 12:20:00 6.5 1 10.3 3.4 5.8 1.1 8.8 3.4 6.1 1.2 9.9 3.4 345 17 1 165 6.4 0.3 7.3 6 05/06/2006 12:30:00 5.9 0.8 8 4.2 5.8 0.9 8 3.4 5.4 0.9 7.6 3 331 17 314 165 6.9 0.3 8 6.5 05/06/2006 12:40:00 6.5 0.8 8.4 4.2 6.5 0.8 8.8 3.8 5.8 1 8.4 3.4 319 16 294 165 7.3 0 7.8 7 05/06/2006 12:50:00 5.9 0.9 8.4 3.4 5.7 1 8.8 3 5.5 0.8 8 3 345 10 345 165 6.3 0.3 7.3 5.7 05/06/2006 13:00:00 5 0.8 6.8 3 5.1 0.7 7.2 3 4.7 0.8 6.8 3 323 13 312 165 6.9 0.4 7.8 6.2 05/06/2006 13:10:00 6.2 1.2 10.7 3.8 6.3 1.2 10.7 4.2 5.6 1.1 9.1 3 313 8 301 165 7.2 0.1 7.5 6.7 05/06/2006 13:20:00 7.3 1.2 9.9 4.2 7.4 1.2 9.9 4.2 6.4 1.2 9.9 3.4 308 7 306 165 5.1 0.7 6.7 4.5 05/06/2006 13:30:00 6.7 1 9.5 3.4 6.7 1 9.5 4.2 5.7 0.8 8.8 3.8 310 8 308 165 4.6 0 4.8 4.3 05/06/2006 13:40:00 10.2 1.1 13.3 7.2 10.2 1.1 13.7 7.6 8.2 1.3 12.6 4.9 303 6 299 165 4.4 0.2 4.8 4.3 05/06/2006 13:50:00 8.2 1 11.1 6.1 8.2 1 10.7 6.1 7.4 1 10.7 4.2 311 8 331 165 4.3 0 4.5 4.3 05/06/2006 14:00:00 9.1 1 12.2 6.5 9.1 1 12.2 6.5 8.1 1 11.1 5.7 311 9 304 165 4.5 0 4.8 4.3 05/06/2006 14:10:00 11.2 1.6 14.9 7.6 11.2 1.6 14.9 7.6 9.7 1.3 13.3 6.8 309 8 302 165 4.4 0 4.8 3.8 05/06/2006 14:20:00 11.5 1.3 16.1 8.4 11.5 1.3 16.1 8.4 10.4 1.2 14.9 7.2 310 7 296 165 4.1 0 4.5 4 05/06/2006 14:30:00 12.3 1.3 15.6 7.6 12.2 1.3 15.6 8 11.2 1.3 14.1 6.5 310 6 308 165 4 0 4.3 3.8 05/06/2006 14:40:00 13.3 1.1 15.6 9.5 13.3 1.1 15.6 9.5 12.8 1.2 15.3 8.4 313 5 312 165 4 0 4.3 3.5 05/06/2006 14:50:00 14 0.8 16.8 11.8 14 0.8 16.8 11.8 13.7 1 16.1 9.1 314 4 310 165 4 0 4.3 3.8 05/06/2006 15:00:00 13.9 0.9 15.6 10.7 13.8 0.9 15.6 10.7 13.5 1 16.1 9.5 316 5 307 165 3.8 0 4 3.8 05/06/2006 15:10:00 13.8 1 15.6 11.1 13.7 1.1 15.6 11.1 13.4 1.2 16.1 9.9 316 5 311 165 3.8 0 4 3.8 05/06/2006 15:20:00 14.7 0.8 17.2 12.2 14.6 0.8 16.8 12.6 14.2 1 16.4 10.7 318 5 321 165 3.6 0.2 3.8 3 05/06/2006 15:30:00 15.5 1.3 17.9 11.1 15.5 1.3 17.9 11.1 15.4 1.3 18.3 11.1 316 5 316 165 3.5 0.2 4 2.8 05/06/2006 15:40:00 16.6 1.1 19.5 13 16.5 1.1 19.9 13.3 16.5 1.2 19.9 13.3 315 4 313 165 3.6 0.1 3.8 3 05/06/2006 15:50:00 16.3 1.1 18.7 12.6 16.2 1.1 18.7 13 16.1 1.2 18.7 12.6 316 4 320 165 3.8 0 4.3 3.3 05/06/2006 16:00:00 15.4 1 18.3 12.6 15.4 1 17.9 12.6 15.4 1.1 17.9 12.6 317 5 319 165 4 0 4 3.8 05/06/2006 16:10:00 15.5 1 17.6 12.2 15.5 1 17.6 11.8 15.1 1.1 17.9 11.5 315 5 317 165 3.8 0 4.3 3.3 05/06/2006 16:20:00 15.4 1.1 18.3 11.5 15.4 1.2 18.7 11.5 14.7 1.1 17.2 11.1 313 5 312 165 3.8 0 4.3 3.5 05/06/2006 16:30:00 16.4 1.2 18.7 13 16.4 1.3 18.7 13 15.3 1.5 18.7 11.1 311 4 309 165 4 0 4.3 3.8 05/06/2006 16:40:00 17 0.9 19.1 14.9 16.9 0.9 19.1 14.5 15.6 1.1 18.3 12.6 312 4 307 165 4 0 4.5 3.8 05/06/2006 16:50:00 16.6 1.1 18.7 13.7 16.6 1.1 18.7 13.3 15.3 1.2 18.3 11.8 311 5 302 165 4.1 0 4.3 4 05/06/2006 17:00:00 16.8 1 19.5 13.7 16.7 1.1 19.5 13.7 15.8 1.2 18.3 10.7 310 4 304 165 4 0 4.3 3.8 05/06/2006 17:10:00 16.6 1.1 19.1 12.6 16.6 1.1 19.5 13 16.4 1.5 19.9 10.3 313 5 308 165 3.9 0 4.3 3.5 05/06/2006 17:20:00 16.8 1.3 20.2 12.6 16.7 1.3 20.2 12.6 16.6 1.4 19.9 11.5 314 5 317 165 4 0 4.3 3.5 05/06/2006 17:30:00 17.2 1.2 19.5 11.8 17.1 1.2 19.9 12.6 16.7 1.3 19.5 11.1 314 4 313 165 4 0 4.3 3.5 05/06/2006 17:40:00 16.6 1.1 19.5 12.6 16.5 1.2 19.5 12.6 16 1.3 19.5 11.8 314 5 316 165 3.8 0.1 4.3 3.3 05/06/2006 17:50:00 15.7 1.2 18.3 11.8 15.6 1.3 17.9 11.5 15.2 1.5 20.2 10.7 315 6 314 165 3.7 0.1 4 3.3 05/06/2006 18:00:00 15.4 1.1 18.3 11.8 15.3 1.1 18.3 12.2 15.2 1.3 18.7 11.8 316 5 312 165 3.8 0 4 3.5 05/06/2006 18:10:00 15.3 1.2 18.3 12.6 15.2 1.2 17.9 12.2 14.7 1.4 18.3 9.1 316 6 308 165 3.8 0.1 4 3.3 05/06/2006 18:20:00 15.1 1.4 18.7 10.7 14.9 1.4 18.7 10.7 14.4 1.7 18.3 9.5 315 5 301 165 3.6 0.1 3.8 3.3 05/06/2006 18:30:00 15.6 1.1 18.7 11.8 15.5 1.2 18.7 11.8 14.6 1.5 17.9 9.9 314 5 312 165 3.5 0 3.5 3 05/06/2006 18:40:00 16.2 1.5 19.5 12.2 16 1.5 19.1 11.8 15.6 1.6 19.1 11.1 314 4 312 165 3.5 0 3.5 3.3 05/06/2006 18:50:00 15.3 1.5 19.1 11.1 15.3 1.5 19.1 11.1 13.9 1.7 18.3 9.1 311 6 304 165 3.5 0.1 3.5 2.8 05/06/2006 19:00:00 15.8 1.1 17.6 12.2 15.7 1.1 17.6 12.2 13.1 1.5 16.8 9.5 308 5 307 165 3.3 0 3.5 3 05/06/2006 19:10:00 15.7 1.2 19.9 12.6 15.7 1.2 19.5 12.6 13.4 1.4 16.8 10.3 309 5 304 165 3.3 0 3.5 3.3 05/06/2006 19:20:00 15.8 1.2 18.3 11.8 15.7 1.1 17.9 12.2 14.5 1.5 17.6 8.4 312 5 305 165 3.2 0 3.5 2.8 05/06/2006 19:30:00 15.5 1.1 17.9 13 15.5 1.1 17.9 13 13.7 1.3 16.8 10.3 310 4 308 165 3 0.1 3.5 2.8 05/06/2006 19:40:00 16.2 0.9 18.3 13.7 16.1 0.9 18.3 13.7 14.2 1.5 17.6 10.3 310 5 319 165 2.9 0.1 3.3 2.3 05/06/2006 19:50:00 16.4 1.3 19.9 12.6 16.2 1.3 19.5 12.2 15 1.6 19.1 10.7 313 5 319 165 2.9 0 3 2.6 05/06/2006 20:00:00 16.5 1.2 20.2 13 16.4 1.2 19.9 12.6 15 1.8 19.5 10.3 311 6 319 165 2.9 0 3 2.6 05/06/2006 20:10:00 16.6 1.1 19.1 13.3 16.5 1.1 18.7 13.3 14.6 1.5 18.3 10.7 310 5 312 165 2.7 0 2.8 2.6 05/06/2006 20:20:00 17.3 1.3 19.9 14.5 17.2 1.3 19.9 14.5 15.1 1.5 19.9 10.3 310 5 308 165 2.7 0 2.8 2.6 05/06/2006 20:30:00 17.6 1.2 20.2 14.1 17.5 1.3 20.2 13.7 15.2 1.5 18.7 10.7 309 5 309 165 2.7 0 2.8 2.6 05/06/2006 20:40:00 18 1.1 20.2 14.5 18 1.2 20.2 14.1 15 1.5 18.3 11.5 308 4 308 165 2.7 0 2.8 2.3 05/06/2006 20:50:00 18.2 0.7 20.2 16.1 18.3 0.7 19.9 15.6 15.1 1.3 18.7 11.8 308 3 309 165 2.6 0 2.8 2.3 05/06/2006 21:00:00 17.3 0.8 18.7 14.1 17.3 0.9 18.7 13.7 14.8 1.2 18.7 11.5 309 3 306 165 2.6 0.1 2.8 2.3 05/06/2006 21:10:00 16.9 1 19.9 13 16.9 1 19.5 13.3 14.5 1.5 17.6 10.3 308 4 310 165 2.5 0 2.8 2.1 05/06/2006 21:20:00 16.5 1 19.1 13.3 16.5 1 19.1 13.3 13 1.5 17.6 9.1 306 3 309 165 2.4 0 2.6 2.3 05/06/2006 21:30:00 15.5 1.3 18.3 12.6 15.6 1.3 18.3 12.6 12.2 1.5 16.4 8.4 304 5 304 165 2.4 0 2.6 1.8 05/06/2006 21:40:00 14.2 1.1 17.6 11.8 14.2 1.1 17.2 11.5 11.6 1.8 17.2 8 305 6 307 165 2.3 0.1 2.6 1.8 05/06/2006 21:50:00 14.1 1.1 17.2 11.1 14.1 1.1 17.6 11.1 11.2 1.3 14.9 8.4 304 5 304 165 2.2 0.1 2.6 1.8 05/06/2006 22:00:00 15.2 0.9 17.2 12.6 15.3 1 17.6 12.2 11.1 1.2 14.9 8.8 302 4 298 165 2.2 0.1 2.3 1.8 05/06/2006 22:10:00 15.3 1 17.6 12.2 15.3 1.1 17.6 12.2 11.9 1.5 15.6 8.8 306 5 305 165 2.1 0.1 2.3 1.6 05/06/2006 22:20:00 15 0.8 17.2 12.6 15.1 0.8 17.6 12.6 12.4 1.7 16.4 8.8 307 5 302 165 2 0.1 2.3 1.6 05/06/2006 22:30:00 15.5 1 17.9 12.6 15.5 1.1 17.9 11.8 13.7 1.3 16.4 10.3 309 4 304 165 2 0.1 2.3 1.4 05/06/2006 22:40:00 15.3 1.3 19.5 11.8 15.3 1.3 19.5 11.8 13.6 1.9 19.1 9.1 308 5 309 165 2 0.1 2.3 1.6 05/06/2006 22:50:00 16 1 18.7 13 16.1 1 18.3 13.3 13.7 1.5 17.6 8.8 308 3 307 165 2 0.1 2.3 1.6 05/06/2006 23:00:00 15 1 17.9 12.2 15 1 17.9 12.6 13 1.4 16.8 9.1 308 4 310 165 1.9 0.1 2.3 1.4 05/06/2006 23:10:00 15.1 1.5 18.3 10.7 15.1 1.6 18.3 10.3 12 1.5 16.1 7.6 306 4 304 165 1.8 0.2 2.1 1.4 05/06/2006 23:20:00 15.8 1.3 17.6 11.1 15.8 1.3 17.9 11.1 12.7 1.3 16.1 8.8 307 3 303 165 1.8 0.1 1.8 1.1 05/06/2006 23:30:00 14.8 1.6 18.3 10.3 14.8 1.7 18.3 10.3 11.4 1.6 16.8 8 305 5 304 165 1.8 0.1 1.8 1.4 05/06/2006 23:40:00 15.1 1.1 17.6 11.5 15.2 1.1 17.9 11.5 12 1.3 15.3 8.4 306 4 302 165 1.8 0 1.8 1.4 05/06/2006 23:50:00 15.4 1.1 17.2 11.8 15.4 1.1 17.2 11.8 12.4 1.5 16.4 8 306 4 303 165 1.8 0 1.8 1.6 05/07/2006 00:00:00 14.9 0.9 17.6 11.8 14.9 0.9 17.2 12.2 12.1 1.3 15.3 8.4 307 4 307 165 1.8 0 1.8 1.6 05/07/2006 00:10:00 14.1 1 16.1 10.3 14.1 1 16.1 11.1 11.7 1.3 16.4 7.2 307 4 307 165 1.7 0 1.8 1.6 05/07/2006 00:20:00 14.6 0.8 16.4 11.8 14.7 0.8 16.4 11.8 12.2 1.1 15.3 9.1 308 3 309 165 1.7 0 1.8 1.6 05/07/2006 00:30:00 14.4 1.1 16.1 10.3 14.3 1.2 16.1 10.3 11.9 1.3 14.9 8 307 4 304 165 1.7 0 1.8 1.6 05/07/2006 00:40:00 14.6 1 16.4 11.1 14.6 1 16.4 11.1 11.6 1.3 15.3 8.4 307 4 304 165 1.6 0 1.6 1.4 05/07/2006 00:50:00 14.1 1.3 16.4 11.1 14.1 1.3 16.8 11.1 11.6 1.3 15.3 8 307 4 305 165 1.5 0 1.6 1.4 05/07/2006 01:00:00 13.8 1.2 16.1 9.5 13.8 1.3 16.1 8.8 11 1.2 14.5 8 306 5 308 165 1.4 0 1.8 1.4 05/07/2006 01:10:00 13.7 1.2 16.8 9.9 13.7 1.2 16.4 9.9 10.6 1.3 14.5 7.2 305 5 295 165 1.4 0 1.6 1.4 05/07/2006 01:20:00 13.8 1 16.4 11.1 13.8 1 16.4 11.1 10.4 1.1 13.7 8 303 5 299 165 1.4 0 1.6 1.4 05/07/2006 01:30:00 13.5 1.1 16.4 10.7 13.5 1.1 16.4 10.7 9.9 1.2 13.7 6.5 302 5 297 165 1.4 0 1.6 1.4 05/07/2006 01:40:00 13.9 1.2 16.1 10.3 14 1.2 16.4 10.3 10.2 1 13 7.6 303 5 302 165 1.2 0 1.4 0.9 05/07/2006 01:50:00 14.1 1.3 16.8 10.3 14.1 1.3 16.8 10.3 9.9 1 13.3 7.6 301 4 297 165 1.1 0 1.4 0.9 05/07/2006 02:00:00 13.4 1.2 16.4 10.7 13.4 1.2 16.4 10.7 10 1.4 14.5 6.8 298 5 295 165 1.1 0 1.4 0.9 05/07/2006 02:10:00 13.2 1 15.6 10.3 13.3 1 16.1 10.3 9.9 1.2 13.7 7.2 300 5 302 165 1 0 1.4 0.7 05/07/2006 02:20:00 13.9 1 16.8 11.5 14 1.1 16.4 11.8 10.1 1.1 15.3 7.6 299 5 313 165 0.9 0.1 1.1 0.2 05/07/2006 02:30:00 13.7 1 16.4 10.7 13.8 1.1 16.4 11.1 10.1 1.2 14.1 6.8 300 5 300 165 0.9 0 1.1 0.2 05/07/2006 02:40:00 13.5 1 15.6 9.9 13.6 1.1 16.1 10.3 10.3 1.2 13.7 7.2 300 5 302 165 0.8 0.1 1.1 0.2 05/07/2006 02:50:00 13.3 1.3 17.2 9.1 13.3 1.4 16.8 9.1 10 1.1 14.1 7.6 300 5 298 165 0.8 0.1 1.1 0.2 05/07/2006 03:00:00 13.4 1.3 16.4 9.5 13.5 1.3 16.4 9.5 9.9 1.2 13.3 6.8 299 5 298 165 0.8 0 1.4 0.7 05/07/2006 03:10:00 13.5 1.5 16.1 10.3 13.6 1.5 16.4 9.9 10.5 1.3 14.5 6.8 302 6 296 165 0.7 0 0.9 0.7 05/07/2006 03:20:00 13.7 1.2 16.1 9.9 13.8 1.2 16.4 9.9 10.3 1.1 13.7 7.6 301 6 300 165 0.6 0 0.9 0.4 05/07/2006 03:30:00 13.2 1.2 15.6 10.3 13.2 1.2 15.6 10.3 10 1.2 14.9 6.8 302 6 303 165 0.5 0 0.7 0.2 05/07/2006 03:40:00 11.7 1.1 14.5 8.4 11.7 1.2 14.1 8 9.2 1.2 13.3 6.5 301 6 298 165 0.3 0 0.7 0.2 05/07/2006 03:50:00 13 1 16.4 10.3 13 1 16.4 10.3 9.5 1.1 12.6 7.2 303 5 297 165 0.1 0 0.2 -0.1 05/07/2006 04:00:00 13.4 1 15.3 9.5 13.5 1 15.6 9.9 9.6 1 12.6 7.6 301 4 302 165 0.1 0 0.4 -0.1 05/07/2006 04:10:00 13.2 1 16.1 9.9 13.2 1 16.4 9.9 9.8 1 12.6 7.6 302 5 301 165 -0.1 0 0.2 -0.3 05/07/2006 04:20:00 13.1 1 14.9 9.5 13.1 1 15.3 9.5 9.2 0.8 11.8 6.8 301 4 302 165 -0.2 0 -0.1 -0.3 05/07/2006 04:30:00 13.3 1.2 15.6 9.1 13.4 1.2 16.1 9.5 9.9 1.1 13.7 7.2 304 5 302 165 -0.3 0 -0.1 -0.3 05/07/2006 04:40:00 12.4 1.1 14.9 9.1 12.4 1.1 14.9 9.1 9.6 1.3 13.7 6.1 302 6 312 165 -0.3 0 -0.1 -0.5 05/07/2006 04:50:00 12.8 1.3 16.4 9.9 12.8 1.3 16.4 9.5 9.9 1.3 13 6.1 303 5 302 165 -0.3 0 -0.1 -0.5 05/07/2006 05:00:00 15.2 1.4 18.3 10.7 15.3 1.5 18.3 11.1 11.5 1.5 16.1 7.6 303 5 304 165 -0.3 0 -0.1 -0.5 05/07/2006 05:10:00 16.5 1.5 19.5 12.6 16.5 1.5 19.5 12.6 13.5 1.7 18.3 9.1 307 5 307 165 -0.3 0 -0.1 -0.5 05/07/2006 05:20:00 16.7 1.3 19.1 13 16.7 1.3 19.5 12.6 13.3 1.7 17.9 9.9 305 6 306 165 -0.5 0 -0.3 -0.8 05/07/2006 05:30:00 15.4 1.3 17.9 11.8 15.5 1.3 18.3 11.8 11.3 1.3 15.3 8.4 299 5 291 165 -0.5 0 -0.3 -0.5 05/07/2006 05:40:00 15.1 1.5 17.9 11.1 15.2 1.5 18.7 10.7 11.4 1.7 16.1 8 303 5 302 165 -0.5 0 -0.3 -0.8 05/07/2006 05:50:00 15.1 1.2 18.3 11.5 15.1 1.3 18.3 11.5 10.9 1.3 16.1 8.4 302 5 299 165 -0.5 0 -0.3 -0.8 05/07/2006 06:00:00 14.8 1.3 18.3 11.1 14.8 1.3 18.3 11.1 11.1 1.5 17.2 8 303 5 301 165 -0.4 0.1 -0.3 -0.8 05/07/2006 06:10:00 15.2 1.5 18.3 11.8 15.2 1.5 18.3 11.8 12 1.7 16.1 8.4 304 6 302 165 -0.3 0 -0.3 -0.5 05/07/2006 06:20:00 14.1 1.3 17.9 10.7 14.1 1.3 17.2 10.7 11.6 1.5 15.6 8 305 6 310 165 -0.3 0 -0.1 -0.5 05/07/2006 06:30:00 13.5 1.3 17.9 9.1 13.5 1.3 17.6 9.1 11.5 1.7 16.4 7.6 306 7 304 165 -0.3 0 -0.1 -0.5 05/07/2006 06:40:00 13.3 1.3 17.6 9.5 13.3 1.3 17.6 9.5 10.2 1.3 15.3 7.6 302 6 308 165 -0.2 0 -0.1 -0.5 05/07/2006 06:50:00 12.9 1.1 15.6 9.9 12.9 1.2 16.1 9.9 10.2 1.3 14.1 7.2 301 6 295 165 -0.1 0 0.2 -0.3 05/07/2006 07:00:00 12.6 1.3 15.6 8.8 12.6 1.3 16.1 8.4 9.9 1.5 14.1 6.1 302 6 300 165 0 0 0.2 -0.1 05/07/2006 07:10:00 13.6 1.5 16.8 8.4 13.6 1.5 16.8 8.4 10.7 1.4 15.3 7.6 303 6 297 165 0 0 0.2 -0.3 05/07/2006 07:20:00 13.7 1.5 17.2 9.9 13.7 1.5 17.2 9.5 10.5 1.2 14.1 7.6 303 6 297 165 0.1 0 0.2 -0.3 05/07/2006 07:30:00 14.2 1.2 17.2 10.7 14.3 1.2 17.2 10.7 11.2 1.3 15.3 7.6 305 6 310 165 0.1 0 0.2 -0.5 05/07/2006 07:40:00 13 1.7 16.4 8.8 12.9 1.7 16.4 8.4 11 1.7 15.6 7.2 305 7 307 165 0.2 0.1 0.7 -0.5 05/07/2006 07:50:00 12.1 1.7 16.8 7.6 12 1.7 16.8 7.6 10 1.7 15.3 5.7 305 7 315 165 0.4 0 0.7 0.2 05/07/2006 08:00:00 11 1.4 14.9 8 11.1 1.5 15.3 8 8.9 1.7 14.1 6.1 298 8 288 165 0.5 0 0.7 0.2 05/07/2006 08:10:00 10.6 1 13 7.6 10.6 1 13 8.4 8.6 1.2 12.2 5.3 300 8 298 165 0.6 0.1 0.9 0.2 05/07/2006 08:20:00 10.6 1.4 14.1 6.8 10.6 1.4 14.5 6.5 9 1.6 13.3 6.1 301 9 309 165 0.7 0.1 0.9 0.2 05/07/2006 08:30:00 11.5 1.3 14.9 8.4 11.6 1.3 14.5 8.4 9.4 1.7 14.1 5.3 300 8 301 165 0.7 0.1 0.9 0.2 05/07/2006 08:40:00 11.7 1.1 14.5 8.8 11.8 1.1 14.9 9.1 9.2 1.3 13 6.5 299 7 294 165 0.8 0 1.1 0.7 05/07/2006 08:50:00 11.8 1.5 14.9 7.2 11.8 1.5 14.9 7.2 9.9 1.5 13.7 5.7 306 7 310 165 0.8 0.1 1.1 0.2 05/07/2006 09:00:00 9.9 1.2 12.6 6.1 9.9 1.2 12.6 6.1 8.1 1.2 11.5 4.9 304 7 297 165 0.9 0.1 1.4 0.2 05/07/2006 09:10:00 9.6 1.5 13.7 5.7 9.6 1.5 13.7 4.9 7.9 1.4 11.8 4.9 303 8 307 165 1.2 0.1 1.4 0.7 05/07/2006 09:20:00 10.1 1.5 13.7 5.7 10.1 1.5 13.7 5.7 8.6 1.5 13 4.9 303 9 287 165 1.2 0 1.4 0.7 05/07/2006 09:30:00 9.1 1.1 11.5 5.7 9.1 1.1 11.5 5.7 7.9 1.1 10.7 4.9 306 6 310 165 1.4 0.1 1.6 0.9 05/07/2006 09:40:00 9.5 1.2 12.2 5.3 9.6 1.2 12.2 6.1 7.9 1.1 11.5 4.9 305 5 305 165 1.6 0 1.8 1.1 05/07/2006 09:50:00 8.8 1 11.5 5.3 8.9 1.1 11.5 5.7 7.5 1.3 11.8 4.6 305 9 302 165 1.6 0 1.8 1.4 05/07/2006 10:00:00 8.3 1.1 11.5 5.7 8.4 1.1 11.1 5.7 7.3 1.2 10.3 4.6 310 8 314 165 2.1 0.1 2.3 1.6 05/07/2006 10:10:00 7.6 1.5 12.2 4.6 7.7 1.4 12.2 4.9 6.7 1.6 12.2 3.8 304 10 307 165 2.1 0 2.3 1.8 05/07/2006 10:20:00 8.1 1.2 11.8 4.9 8.2 1.2 11.5 4.9 7.3 1.5 11.8 4.2 301 12 293 165 2.1 0 2.3 1.8 05/07/2006 10:30:00 7.4 1 9.9 4.2 7.5 1 9.9 4.2 6.6 1.2 9.1 4.2 298 13 297 165 2.4 0.2 2.8 1.8 05/07/2006 10:40:00 7.9 1.1 10.3 5.3 8 1.1 10.3 4.9 7 1.4 10.7 4.2 298 14 292 165 2.4 0 2.8 2.1 05/07/2006 10:50:00 8.1 1.2 11.8 4.9 8.2 1.2 11.5 4.9 7.2 1.5 10.7 4.2 304 12 302 165 2.6 0 3 2.3 05/07/2006 11:00:00 9.6 1.2 12.2 6.5 9.6 1.2 12.2 6.5 8.8 1.7 12.6 4.9 311 9 321 165 2.5 0.1 2.8 2.3 05/07/2006 11:10:00 9.8 1.2 14.1 7.2 9.8 1.2 14.1 6.8 8.6 1.4 12.6 5.7 310 6 307 165 2.4 0.1 3 2.3 05/07/2006 11:20:00 8.9 1.2 11.8 5.3 8.9 1.2 11.5 5.3 7.9 1.4 11.1 3.4 309 10 298 165 2.6 0 2.8 2.3 05/07/2006 11:30:00 8.7 1.3 12.2 5.7 8.8 1.3 12.6 5.7 7.8 1.6 12.2 5.3 302 14 288 165 2.6 0 2.8 2.6 05/07/2006 11:40:00 9 1.3 11.8 3.4 9.1 1.3 12.2 3.8 7.9 1.6 13.3 4.2 295 12 282 165 2.9 0.1 3.5 2.6 05/07/2006 11:50:00 10.6 1.7 14.5 5.3 10.6 1.6 14.1 5.7 9.6 1.5 12.2 4.9 307 10 308 165 2.4 0.1 3 2.3 05/07/2006 12:00:00 9.9 1.2 13 6.5 9.9 1.2 13.3 6.8 8.6 1.4 12.2 5.3 309 8 300 165 2.7 0.2 3 2.1 05/07/2006 12:10:00 8.9 1.1 12.6 6.8 9 1.1 12.2 6.5 7.9 1.4 11.5 4.6 307 9 301 165 2.9 0.1 3.3 2.6 05/07/2006 12:20:00 8.5 1.2 12.2 4.9 8.5 1.1 12.2 5.3 7.8 1.4 10.7 4.6 309 11 304 165 3.2 0 3.5 2.8 05/07/2006 12:30:00 8.1 0.9 10.7 5.3 8.2 0.9 11.1 5.3 7.3 1.1 10.7 4.6 299 15 294 165 3.3 0 3.8 3 05/07/2006 12:40:00 8.7 1 11.1 6.5 8.7 1 11.1 6.5 7.3 1.2 10.3 4.9 308 6 297 165 3.4 0.1 4.3 3 05/07/2006 12:50:00 7.8 0.9 10.3 5.3 7.8 0.8 9.9 5.7 6.5 0.9 9.5 3.8 306 8 297 165 3.8 0.2 4.3 3.3 05/07/2006 13:00:00 7.7 0.9 9.9 5.3 7.7 0.9 9.5 4.9 6.9 0.9 9.1 3.8 311 6 317 165 3.6 0 3.8 3.5 05/07/2006 13:10:00 7.5 0.9 9.9 5.3 7.5 0.9 9.9 5.3 6.9 1 9.9 4.6 315 7 305 165 4.2 0.1 4.8 3.8 05/07/2006 13:20:00 8.4 0.9 10.7 5.3 8.5 0.8 11.1 5.7 7.1 0.9 9.1 4.6 304 9 301 165 3.4 0.2 4 3 05/07/2006 13:30:00 7.4 0.8 9.9 4.6 7.6 0.8 10.7 4.9 7 1.2 10.3 4.2 287 12 268 165 3.3 0.1 3.8 3 05/07/2006 13:40:00 7.7 1 10.7 4.6 7.9 1.1 10.3 4.6 7.1 1.4 10.7 4.2 292 11 302 165 3.3 0.1 4 3 05/07/2006 13:50:00 7.4 0.9 10.3 4.9 7.5 0.9 10.3 5.3 6.5 0.9 8.8 4.2 309 7 305 165 3.5 0.3 4.3 3 05/07/2006 14:00:00 6.5 1.3 9.9 3 6.6 1.2 9.9 3 5.8 1.3 9.5 2.6 304 15 287 165 4.1 0.1 4.5 3.5 05/07/2006 14:10:00 7.6 1.2 10.3 3.8 7.6 1.1 10.3 3.8 6.6 1.4 10.3 3 304 11 312 165 4 0.3 5 3.5 05/07/2006 14:20:00 8.1 0.8 9.9 5.3 8 0.8 9.9 5.3 7.4 1.1 10.3 3 311 8 310 165 4.6 0.2 5.2 4.3 05/07/2006 14:30:00 7.2 0.9 8.8 3 7.2 0.9 9.1 3 5.9 0.9 9.5 3.8 304 9 306 165 4.8 0.1 5.2 4.5 05/07/2006 14:40:00 6.6 1.2 9.5 3 6.7 1.2 9.5 3.4 5.9 1.2 8.4 3 303 13 301 165 4.8 0.2 5.2 4.3 05/07/2006 14:50:00 6.6 1 8.8 3.8 6.6 1 8.8 3.8 5.4 1.2 8.8 2.3 305 9 307 165 5.4 0.3 6.2 4.8 05/07/2006 15:00:00 6.3 1 9.1 3.4 6.3 1 8.8 3.4 5.5 1 8.4 3 306 12 299 165 5.3 0.2 5.7 4.8 05/07/2006 15:10:00 7.9 0.8 9.9 5.7 7.9 0.8 9.9 5.7 7 1 9.1 4.2 308 9 297 165 4.4 0.3 5.2 4 05/07/2006 15:20:00 7 1 9.9 4.2 7 1 10.3 4.2 5.9 1.1 8.4 2.6 308 7 317 165 4.4 0.3 5 4 05/07/2006 15:30:00 6.8 1 10.3 3.8 6.8 1 10.7 4.2 6 1.1 9.9 3.4 309 9 292 165 4.8 0.2 5.5 4.5 05/07/2006 15:40:00 7.5 1 9.9 4.6 7.5 1 9.9 4.6 6.6 1.2 9.1 4.2 310 8 306 165 4.5 0 4.8 4.3 05/07/2006 15:50:00 7.3 0.9 9.1 4.9 7.2 0.9 9.1 4.6 6.1 1 8.4 3 307 7 303 165 4.4 0.1 4.8 3.8 05/07/2006 16:00:00 6.2 1.4 9.5 2.3 6.3 1.4 9.1 2.3 5.4 1.2 8.4 2.3 297 14 303 165 4 0.1 4.5 3.8 05/07/2006 16:10:00 6 1.1 9.9 2.6 6 1 9.5 3.8 5.4 1.1 8.4 3 302 13 280 165 4.1 0.3 4.8 3.5 05/07/2006 16:20:00 6.8 1 8.4 3.4 6.7 1 8.4 3.4 6 1 8.4 3 309 8 305 165 3.8 0 4 3.8 05/07/2006 16:30:00 6.6 1 9.1 3.8 6.6 1 9.5 3.4 5.9 1.2 9.1 2.3 309 8 310 165 4.4 0.4 5 3.8 05/07/2006 16:40:00 6.7 1.2 9.1 3.4 6.7 1.2 9.1 3.4 6 1.1 8.8 3.4 310 9 313 165 4.9 0.1 5.5 4.5 05/07/2006 16:50:00 5.9 1.2 8.8 3 6 1.1 8.8 3.4 5.5 1.2 8.8 3 297 17 325 165 4.4 0.4 5.2 3.8 05/07/2006 17:00:00 5.8 1 8 3 5.8 1 8 2.6 4.9 1 7.6 2.6 298 12 305 165 4.5 0.2 5 4 05/07/2006 17:10:00 7.6 0.9 9.9 5.3 7.5 0.9 9.9 5.3 6.4 1 8.8 3.8 309 6 309 165 4 0 4.5 3.8 05/07/2006 17:20:00 8.2 0.8 9.9 6.1 8.1 0.9 10.3 5.7 6.9 0.9 9.1 4.6 308 5 316 165 4.3 0 4.5 4 05/07/2006 17:30:00 7.6 1 9.9 5.3 7.6 1 9.9 4.9 6.3 1 8.8 4.2 306 7 309 165 3.8 0.3 4.3 3.3 05/07/2006 17:40:00 7.9 0.7 10.3 6.1 8 0.7 10.3 6.1 6.5 0.9 9.9 4.2 304 6 300 165 3.5 0.2 4 3.3 05/07/2006 17:50:00 7.2 0.7 8.8 5.3 7.2 0.7 8.8 5.7 6.5 0.7 8.4 4.6 311 4 305 165 4 0 4.3 3.8 05/07/2006 18:00:00 6.3 0.7 8.4 4.2 6.3 0.6 8 4.6 5.6 0.8 8.4 3 309 5 314 165 4.2 0.1 4.5 3.8 05/07/2006 18:10:00 5.1 0.9 7.6 2.6 5.2 0.9 8 3 4.6 1 6.8 1.9 305 11 296 165 4.4 0.2 4.8 4 05/07/2006 18:20:00 5.9 0.9 8.4 3.4 5.8 0.9 8.4 3.4 5 1.1 8 2.6 308 9 310 165 4.6 0 5 4.3 05/07/2006 18:30:00 6.4 0.7 8.4 4.9 6.4 0.7 8 4.6 6.1 0.8 8 3.8 315 6 317 165 4.1 0.1 4.5 3.8 05/07/2006 18:40:00 5.4 0.9 7.2 3.4 5.3 0.8 7.2 3.4 4.8 1 7.6 2.6 309 8 306 165 4.1 0.2 4.8 3.8 05/07/2006 18:50:00 4.2 0.6 5.7 2.6 4.3 0.6 5.7 2.6 3.3 0.7 5.3 1.9 305 9 296 165 4.6 0.1 5 4.5 05/07/2006 19:00:00 3.5 0.7 5.3 1.5 3.7 0.6 5.3 1.9 3.3 0.6 4.6 1.9 294 13 304 165 4.4 0.2 4.8 3.8 05/07/2006 19:10:00 3.3 0.9 5.3 1.1 3.5 0.8 5.7 1.5 3 0.7 4.6 1.5 288 17 299 165 4 0 4.3 3.5 05/07/2006 19:20:00 2.7 0.7 4.6 0.7 3.2 0.7 4.9 1.5 3 0.7 4.6 1.5 275 13 272 165 3.5 0 3.8 3.3 05/07/2006 19:30:00 3.2 0.7 4.6 1.5 3.3 0.7 4.9 1.5 2.9 0.8 4.6 1.1 291 9 289 165 3.3 0.3 3.8 2.6 05/07/2006 19:40:00 2.7 0.6 4.6 1.1 2.8 0.5 4.6 1.5 2.5 0.5 3.8 1.5 283 8 290 165 2.6 0.1 3.3 2.3 05/07/2006 19:50:00 2.9 0.6 4.6 1.9 3.1 0.5 4.6 1.9 2.7 0.6 3.8 1.5 284 12 292 165 2.7 0.2 3 2.3 05/07/2006 20:00:00 3.5 0.5 4.6 2.3 3.7 0.5 4.6 2.3 3.1 0.5 4.2 1.5 295 8 302 165 2.9 0 3.3 2.6 05/07/2006 20:10:00 3.4 0.3 4.2 2.3 3.6 0.3 4.6 2.3 3.3 0.5 4.6 1.9 282 5 289 165 2.6 0.1 3.3 2.1 05/07/2006 20:20:00 3.7 0.2 4.2 3 3.8 0.2 4.2 3 3.7 0.3 4.6 3 281 2 274 165 2.1 0.2 2.6 1.6 05/07/2006 20:30:00 3.9 0.2 4.6 3.4 3.9 0.2 4.6 3.4 3.6 0.3 4.2 3 286 2 286 165 1.8 0.1 2.1 1.4 05/07/2006 20:40:00 3.1 0.3 3.8 2.6 3.3 0.3 3.8 2.6 3.1 0.3 3.8 2.3 284 1 290 165 1.8 0 1.8 1.4 05/07/2006 20:50:00 3 0.3 4.2 2.3 3.2 0.3 4.2 2.6 3.1 0.3 4.2 2.3 279 5 274 165 1.7 0 1.8 1.6 05/07/2006 21:00:00 2.6 0.5 3.8 1.1 3.2 0.4 4.2 2.6 3.1 0.3 3.8 2.6 257 7 252 165 1.7 0 1.8 1.6 05/07/2006 21:10:00 2.5 0.4 3.4 1.5 3.3 0.2 3.8 2.6 3.3 0.2 3.8 2.6 261 5 260 165 1.8 0 1.8 1.6 05/07/2006 21:20:00 2.2 0.4 3.4 1.1 2.6 0.4 3.4 1.9 2.7 0.4 3.4 1.9 266 10 250 165 1.7 0 1.8 1.6 05/07/2006 21:30:00 1.8 0.3 2.6 1.1 2.1 0.3 2.6 1.5 2.2 0.2 2.6 1.5 277 4 282 165 1.5 0 1.6 1.4 05/07/2006 21:40:00 1.5 0.3 2.3 0.7 1.9 0.3 3 1.1 2.1 0.2 2.6 1.5 258 6 268 165 1.7 0 1.8 1.6 05/07/2006 21:50:00 1.6 0.4 2.3 0.7 2 0.4 2.6 0.7 2.2 0.3 2.6 1.5 249 7 249 165 1.8 0 1.8 1.6 05/07/2006 22:00:00 1.3 0.3 2.3 0.4 1.7 0.3 2.6 0.7 2 0.2 2.6 1.5 266 8 257 165 1.7 0 1.8 1.4 05/07/2006 22:10:00 0.9 0.4 1.9 0.4 1.1 0.4 2.3 0.4 1.4 0.3 2.3 0.7 281 1 277 165 1.4 0 1.6 0.9 05/07/2006 22:20:00 0.5 0.2 1.1 0.4 0.6 0.3 1.5 0.4 1.1 0.3 1.5 0.7 282 0 282 165 1.5 0 1.6 1.1 05/07/2006 22:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.5 0.2 1.1 0.4 282 0 165 165 1.4 0.1 1.6 0.9 05/07/2006 22:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.7 0.3 1.5 0.4 210 21 165 165 1.4 0.2 1.6 0.9 05/07/2006 22:50:00 0.4 0.2 1.1 0.4 0.4 0.2 1.1 0.4 1 0.2 1.5 0.7 172 9 186 165 1.1 0 1.4 0.9 05/07/2006 23:00:00 0.4 0.2 1.1 0.4 0.4 0 0.4 0.4 0.9 0.3 1.5 0.4 169 5 164 165 0.9 0 1.1 0.9 05/07/2006 23:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0.1 0.7 0.4 175 0 165 165 0.9 0.1 1.4 0.9 05/07/2006 23:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 175 0 165 165 0.7 0 0.9 0.7 05/07/2006 23:30:00 1 0.6 1.9 0.4 0.9 0.6 1.9 0.4 1 0.6 2.3 0.4 187 8 191 165 0.9 0 1.1 0.7 05/07/2006 23:40:00 1.9 0.3 2.6 1.1 2 0.3 2.6 1.1 2.1 0.3 2.6 1.5 181 4 182 165 1.1 0 1.4 0.7 05/07/2006 23:50:00 1.7 0.3 2.6 1.1 1.7 0.3 2.3 1.1 2 0.3 3 1.1 170 5 168 165 1 0 1.4 0.9 05/08/2006 00:00:00 1.8 0.5 2.6 0.4 1.9 0.5 2.6 0.4 2 0.4 3 1.1 177 5 183 165 0.9 0 1.1 0.7 05/08/2006 00:10:00 2.6 0.4 3.4 1.9 2.7 0.4 3.4 1.9 3 0.3 3.8 2.6 188 3 193 165 1.2 0.1 1.4 0.9 05/08/2006 00:20:00 2.5 0.5 3.4 1.5 2.6 0.5 3.4 1.5 2.9 0.5 3.8 1.9 178 5 179 165 1.2 0 1.4 0.9 05/08/2006 00:30:00 2.2 0.4 3 1.5 2.2 0.4 3 1.5 2.5 0.3 3.4 1.9 165 5 163 165 0.9 0.1 1.1 0.7 05/08/2006 00:40:00 2.3 0.5 3.8 1.1 2.3 0.5 3.4 1.1 2.4 0.3 3.4 1.9 174 11 181 165 0.7 0 0.9 0.7 05/08/2006 00:50:00 1.9 0.4 3 0.7 1.9 0.4 2.6 0.4 2.2 0.4 3.4 0.7 186 10 177 165 1.1 0.1 1.4 0.9 05/08/2006 01:00:00 1.7 0.5 2.6 0.4 1.7 0.6 2.6 0.4 2.2 0.4 3 1.1 185 6 193 165 1.2 0 1.4 0.9 05/08/2006 01:10:00 1.8 0.4 2.6 0.7 1.8 0.4 2.6 0.4 2.2 0.3 3 1.5 175 3 170 165 1 0 1.4 0.9 05/08/2006 01:20:00 1.6 0.3 2.3 1.1 1.7 0.3 2.3 1.1 1.9 0.3 2.6 1.1 174 6 165 165 1 0 1.1 0.9 05/08/2006 01:30:00 1.3 0.3 1.9 0.7 1.3 0.3 1.9 0.7 1.8 0.3 2.6 1.1 164 3 164 165 0.9 0 1.1 0.9 05/08/2006 01:40:00 1 0.3 1.5 0.4 0.9 0.3 1.5 0.4 1.7 0.2 2.3 1.1 163 3 164 165 1.1 0 1.4 0.9 05/08/2006 01:50:00 1.4 0.4 2.3 0.4 1.5 0.3 2.3 0.7 2 0.2 3 1.5 154 9 161 165 1.1 0 1.4 0.9 05/08/2006 02:00:00 1.7 0.3 2.6 0.7 1.8 0.4 2.6 0.7 2.3 0.3 3 1.9 151 6 145 165 1.1 0 1.4 0.9 05/08/2006 02:10:00 1.7 0.3 2.3 1.1 1.8 0.3 2.6 1.1 2.3 0.2 3 1.9 158 4 160 165 1.1 0 1.4 0.9 05/08/2006 02:20:00 1.4 0.4 2.3 0.4 1.5 0.4 2.3 0.4 2.1 0.3 2.6 1.5 163 2 159 165 1 0 1.4 0.9 05/08/2006 02:30:00 1.1 0.2 1.5 0.7 1.3 0.2 1.9 0.7 1.9 0.2 2.3 1.5 164 0 164 165 1 0 1.4 0.9 05/08/2006 02:40:00 1.1 0.2 1.5 0.4 1.2 0.3 1.9 0.4 1.9 0.2 2.3 1.5 158 5 164 165 1 0 1.4 0.9 05/08/2006 02:50:00 1 0.3 1.9 0.4 0.9 0.4 1.9 0.4 1.5 0.2 1.9 1.1 151 3 149 165 1 0 1.4 0.9 05/08/2006 03:00:00 0.6 0.3 1.5 0.4 0.9 0.4 1.9 0.4 1.5 0.2 2.3 1.1 146 5 158 165 0.9 0 1.1 0.9 05/08/2006 03:10:00 0.4 0 0.4 0.4 0.4 0.2 1.1 0.4 1.2 0.3 1.9 0.4 144 4 165 165 1 0 1.4 0.9 05/08/2006 03:20:00 0.5 0.3 1.5 0.4 0.8 0.5 1.9 0.4 1.4 0.4 2.3 0.7 145 0 145 165 1 0 1.1 0.9 05/08/2006 03:30:00 1.6 0.3 2.3 0.7 1.7 0.3 2.6 1.1 2.2 0.2 3 1.9 149 5 162 165 0.8 0 1.1 0.9 05/08/2006 03:40:00 2 0.3 2.6 1.1 2.2 0.3 3 1.5 2.4 0.3 3.4 1.9 152 6 153 165 0.9 0 1.1 0.9 05/08/2006 03:50:00 2.1 0.4 2.6 1.1 2.2 0.3 2.6 1.5 2.5 0.3 3 1.5 149 5 153 165 0.9 0 1.1 0.9 05/08/2006 04:00:00 2 0.4 3 1.1 2.2 0.4 3 1.5 2.5 0.3 3 1.9 149 5 151 165 0.9 0 1.1 0.9 05/08/2006 04:10:00 1.9 0.4 2.6 1.1 2.1 0.3 3 1.5 2.4 0.2 3 1.9 148 6 145 165 0.8 0 1.1 0.7 05/08/2006 04:20:00 2.1 0.4 3 0.7 2.3 0.4 3.4 1.1 2.6 0.3 3 1.9 150 4 156 165 0.8 0 0.9 0.7 05/08/2006 04:30:00 2.6 0.3 3.4 1.9 2.7 0.3 3.4 1.9 2.8 0.3 3.4 1.9 147 4 145 165 0.8 0 0.9 0.7 05/08/2006 04:40:00 2.5 0.4 3.4 1.5 2.6 0.4 3.4 1.9 3 0.3 3.4 2.3 146 5 141 165 0.9 0 1.1 0.9 05/08/2006 04:50:00 3.1 0.5 4.2 1.5 3.2 0.5 4.2 1.9 3.3 0.4 4.2 2.6 147 5 147 165 1.1 0 1.4 0.9 05/08/2006 05:00:00 3.5 0.5 4.6 2.3 3.7 0.4 4.6 2.6 3.8 0.4 4.6 2.6 143 4 145 165 1.1 0 1.4 0.9 05/08/2006 05:10:00 3.4 0.2 3.8 2.6 3.5 0.2 3.8 2.6 3.6 0.3 4.2 2.6 143 3 142 165 1.2 0 1.4 0.9 05/08/2006 05:20:00 2.7 0.5 3.8 1.1 2.8 0.6 3.8 1.5 3.1 0.5 3.8 1.9 141 5 150 165 1.2 0 1.4 1.1 05/08/2006 05:30:00 2.9 0.4 4.2 1.9 3 0.4 4.2 1.9 3.1 0.4 4.2 2.3 140 5 135 165 1.2 0 1.4 1.1 05/08/2006 05:40:00 3.2 0.4 4.6 2.3 3.3 0.4 4.6 2.3 3.4 0.4 4.6 2.6 139 6 135 165 1.4 0 1.6 1.4 05/08/2006 05:50:00 3.5 0.5 4.6 1.9 3.6 0.6 4.9 1.9 3.8 0.5 4.9 2.3 144 8 148 165 1.4 0 1.6 1.4 05/08/2006 06:00:00 4.1 0.6 5.3 2.6 4.2 0.5 5.3 2.6 4.2 0.5 5.3 3 136 8 136 165 1.5 0 1.6 1.4 05/08/2006 06:10:00 4.5 0.7 6.1 3 4.6 0.7 6.5 3 4.7 0.6 6.1 3.4 139 8 135 165 1.2 0.1 1.6 0.9 05/08/2006 06:20:00 2.9 0.5 4.2 1.5 3 0.5 4.2 1.9 3.1 0.4 3.8 1.9 136 5 137 165 0.9 0 1.1 0.9 05/08/2006 06:30:00 4.4 0.6 5.7 2.3 4.5 0.6 5.7 2.6 4.4 0.5 5.7 3.4 142 5 144 165 1.1 0 1.4 0.9 05/08/2006 06:40:00 3.3 0.6 4.9 2.3 3.4 0.5 4.9 2.3 3.6 0.5 4.9 2.6 140 6 140 165 1.2 0 1.4 1.1 05/08/2006 06:50:00 3.4 0.3 4.2 2.6 3.5 0.3 4.6 2.6 3.7 0.3 4.6 3 142 4 148 165 1.3 0 1.6 1.1 05/08/2006 07:00:00 3.1 0.4 3.8 2.3 3.2 0.4 4.2 2.3 3.4 0.4 4.6 2.6 138 8 127 165 1.4 0 1.6 1.4 05/08/2006 07:10:00 3.6 0.5 4.9 2.3 3.8 0.5 5.3 2.3 3.9 0.5 5.3 2.6 134 8 126 165 1.2 0 1.4 1.1 05/08/2006 07:20:00 4.5 0.8 6.8 2.3 4.6 0.8 6.8 2.3 4.7 0.8 7.2 2.6 139 8 138 165 1 0 1.4 0.9 05/08/2006 07:30:00 3.7 0.6 5.3 1.9 3.9 0.6 5.3 1.9 3.8 0.6 5.3 1.9 118 9 135 165 0.9 0 1.1 0.9 05/08/2006 07:40:00 3 0.5 4.2 1.9 3.1 0.5 4.2 2.3 3.1 0.4 4.2 2.3 108 7 116 165 1 0 1.4 0.9 05/08/2006 07:50:00 4.2 0.6 5.7 2.3 4.3 0.6 6.1 2.6 4.1 0.6 5.3 2.6 104 6 94 165 1.1 0 1.4 0.9 05/08/2006 08:00:00 4.3 0.4 5.7 3 4.5 0.5 5.7 3 4.2 0.5 5.7 3 98 6 99 165 1.2 0 1.4 1.1 05/08/2006 08:10:00 5.7 0.7 7.6 4.2 5.9 0.8 8 4.2 5.6 0.7 7.6 3.8 111 4 112 165 1.4 0 1.6 1.4 05/08/2006 08:20:00 6 0.7 8.8 4.6 6.2 0.7 8.4 4.6 6 0.7 7.6 4.2 123 9 130 165 1.4 0 1.6 1.4 05/08/2006 08:30:00 5 0.6 6.8 3.8 5.1 0.5 6.8 3.8 5.1 0.5 6.5 3.8 133 6 145 165 1.4 0.1 1.6 0.9 05/08/2006 08:40:00 4.6 0.6 6.1 2.6 4.8 0.6 6.5 3 4.6 0.6 6.1 2.6 135 7 136 165 1.7 0 1.8 0.9 05/08/2006 08:50:00 5.8 0.7 7.2 4.2 6.3 0.6 8 4.6 6.1 0.8 8 3.8 133 8 128 165 1.7 0 1.8 1.1 05/08/2006 09:00:00 6.2 1.3 9.9 3.4 6.4 1.3 10.3 3.4 6.1 1.3 9.5 3.8 131 8 127 165 1.7 0 1.8 1.4 05/08/2006 09:10:00 8.1 1 11.1 5.7 8.2 1 11.5 5.7 7.4 1.2 10.7 4.6 134 7 129 165 1.7 0 1.8 1.4 05/08/2006 09:20:00 8.4 1 11.1 6.1 8.4 1 11.5 6.1 8.1 1.2 10.3 4.9 142 8 135 165 1.8 0 1.8 1.4 05/08/2006 09:30:00 8.8 0.8 10.7 6.5 8.9 0.8 10.7 6.5 8.9 0.9 11.1 6.5 140 6 135 165 1.9 0 2.1 1.8 05/08/2006 09:40:00 7.6 0.9 9.9 5.3 7.7 0.8 9.9 6.1 7.8 1.1 9.9 4.9 134 7 135 165 1.9 0 2.1 1.8 05/08/2006 09:50:00 7.8 0.9 9.9 5.3 7.8 0.9 9.9 5.3 7.7 1 10.3 5.7 125 6 135 165 2 0 2.1 1.8 05/08/2006 10:00:00 8.7 1 11.5 6.1 8.8 1 11.5 6.1 8.8 1 11.5 6.5 125 6 124 165 2 0 2.3 1.8 05/08/2006 10:10:00 8.2 0.9 10.7 5.7 8.3 0.9 10.7 5.7 8.2 0.8 10.7 6.1 135 9 140 165 1.9 0 2.1 1.8 05/08/2006 10:20:00 9.4 1.2 13.3 6.8 9.4 1.2 13.3 6.8 9.2 1.5 13.7 6.1 137 9 156 165 2.1 0 2.3 1.8 05/08/2006 10:30:00 8.2 0.9 11.8 6.5 8.5 0.9 12.2 6.8 8.2 0.9 11.8 5.7 126 5 120 165 2.1 0 2.3 1.8 05/08/2006 10:40:00 10.5 1.5 13.3 7.6 10.6 1.5 13.7 7.6 10.5 1.4 13.7 7.2 138 7 132 165 2.2 0 2.6 1.8 05/08/2006 10:50:00 8.4 0.9 10.7 5.3 8.7 0.9 10.7 5.7 8.4 0.9 10.7 4.9 128 7 137 165 2.1 0.2 2.6 1.8 05/08/2006 11:00:00 7.7 0.8 9.9 5.3 7.9 0.8 9.9 5.7 7.6 0.7 9.5 5.7 119 7 119 165 2.3 0.1 2.8 1.8 05/08/2006 11:10:00 9.3 1.5 13 6.1 9.5 1.5 13 6.1 9 1.6 13.7 5.3 115 6 110 165 2.6 0.1 2.8 2.3 05/08/2006 11:20:00 10.3 1.2 13.3 7.6 10.5 1.2 13.3 8 10.3 1.3 13.7 7.2 126 6 125 165 2.1 0.1 2.3 1.8 05/08/2006 11:30:00 9.3 1 11.5 6.8 9.5 1 11.8 7.2 9.1 1 11.8 6.8 121 4 122 165 1.8 0 2.3 1.6 05/08/2006 11:40:00 8.9 0.8 10.7 6.1 9.1 0.8 11.1 6.1 8.5 0.9 10.7 6.1 113 6 118 165 2.6 0.2 2.8 1.8 05/08/2006 11:50:00 9.6 0.8 11.8 6.8 9.9 0.9 11.8 6.5 9.3 1 12.6 6.5 110 5 116 165 2.7 0 2.8 2.3 05/08/2006 12:00:00 9.5 1.1 12.2 6.5 9.8 1.1 13 6.5 9.1 1.2 11.8 5.7 108 6 101 165 2.9 0 3 2.6 05/08/2006 12:10:00 10.4 1.7 15.3 6.5 10.7 1.7 15.6 6.1 9.9 1.7 15.6 5.7 116 8 114 165 2.8 0 3 2.3 05/08/2006 12:20:00 11.6 1.7 15.6 8 11.8 1.7 15.6 8.4 11.5 1.9 15.3 6.8 123 5 126 165 2.4 0.1 2.6 1.8 05/08/2006 12:30:00 9.4 1.3 13 5.7 9.6 1.3 13.3 5.7 9.1 1.2 13.3 4.9 116 8 105 165 2.7 0 2.8 2.3 05/08/2006 12:40:00 10.3 1 12.2 5.7 10.5 1 13 5.7 9.8 1.1 12.2 6.5 112 7 114 165 2.5 0 2.8 2.3 05/08/2006 12:50:00 9.9 1.2 13.3 6.5 10.1 1.2 13.3 6.8 9.3 1.3 13 6.5 107 6 102 165 2.7 0 2.8 2.3 05/08/2006 13:00:00 10.5 1.5 13.3 6.5 10.8 1.5 13.3 6.5 9.9 1.5 13.3 5.3 108 7 105 165 2.8 0 3 2.3 05/08/2006 13:10:00 10.3 1.2 13 6.8 10.5 1.2 13.3 7.2 9.8 1.2 13.3 7.2 112 8 104 165 2.9 0 3 2.6 05/08/2006 13:20:00 9.4 1.9 13.3 4.2 9.6 2 13.7 3.8 9 1.9 13.3 3.8 117 8 102 165 3 0 3.3 2.6 05/08/2006 13:30:00 10.9 1.2 13.7 8 11.2 1.2 13.7 7.6 10.3 1.3 13.3 6.8 107 6 105 165 3 0 3.3 2.8 05/08/2006 13:40:00 11.7 1.3 15.3 8.8 12 1.3 15.6 8.8 11.2 1.4 16.4 7.6 109 8 112 165 2.9 0 3.3 2.6 05/08/2006 13:50:00 11.9 1.3 14.5 8 12.1 1.4 14.5 8 11.3 1.6 14.5 7.2 114 7 113 165 2.8 0.1 3 2.3 05/08/2006 14:00:00 10.7 1.2 13.3 7.2 10.9 1.2 13.7 6.8 10.2 1.3 13.7 6.5 114 7 116 165 2.7 0 3 2.3 05/08/2006 14:10:00 10.3 1.4 14.1 7.2 10.5 1.4 14.1 7.6 9.7 1.3 14.5 6.5 109 7 99 165 2.7 0 3 2.6 05/08/2006 14:20:00 12.8 1.2 15.3 8 13.1 1.2 15.6 8 12.3 1.5 15.6 8 110 6 108 165 2.9 0 3 2.8 05/08/2006 14:30:00 11 1.5 14.1 7.6 11.2 1.5 14.9 7.6 10.4 1.5 14.1 6.8 109 9 98 165 2.9 0 3 2.6 05/08/2006 14:40:00 12.5 1.5 16.4 9.1 12.8 1.5 16.8 8.4 12.1 1.7 16.4 8.4 111 8 106 165 2.8 0 3 2.6 05/08/2006 14:50:00 12.4 1.5 15.6 7.6 12.6 1.6 16.4 7.2 11.6 1.7 15.3 7.2 111 8 116 165 2.8 0 3 2.6 05/08/2006 15:00:00 12.5 1.3 16.8 8.8 12.8 1.4 17.2 8.8 11.9 1.7 16.4 6.5 114 9 126 165 2.8 0 3 2.6 05/08/2006 15:10:00 11.7 1.8 16.4 6.1 11.9 1.8 16.1 6.1 11.3 1.7 16.4 6.1 119 9 126 165 2.6 0 2.8 2.6 05/08/2006 15:20:00 11.4 2 16.1 6.5 11.6 2 16.4 6.8 11 2 16.4 6.8 117 9 119 165 2.3 0 2.8 2.3 05/08/2006 15:30:00 11.5 2.2 17.2 6.8 11.8 2.2 17.6 6.8 11.1 2.4 16.8 6.1 116 9 118 165 2.3 0 2.3 2.1 05/08/2006 15:40:00 10.9 1.7 16.1 5.7 11.2 1.8 16.4 5.7 10.7 1.7 15.6 6.5 113 8 111 165 2.2 0 2.3 2.1 05/08/2006 15:50:00 11.4 1.3 14.5 8.4 11.7 1.3 14.9 8 10.8 1.4 15.3 7.6 108 7 106 165 2.4 0.1 2.8 2.1 05/08/2006 16:00:00 12.8 1.4 16.1 9.1 13.1 1.4 16.4 9.5 12.2 1.5 15.6 8.4 115 7 119 165 3 0.1 3.3 2.6 05/08/2006 16:10:00 12.5 1.5 16.8 9.1 12.7 1.5 16.8 9.5 12.2 1.6 15.6 7.2 121 8 119 165 3.5 0.1 3.5 3 05/08/2006 16:20:00 12 1 15.6 9.1 12.2 1.1 16.1 9.5 11.9 1.2 15.3 8.4 123 6 112 165 3.6 0 4 3.5 05/08/2006 16:30:00 11.2 1.2 14.1 8 11.4 1.2 14.5 8 11.1 1.2 14.1 8 130 8 123 165 3.9 0 4 3.5 05/08/2006 16:40:00 11.6 1 13.7 8.8 11.7 1 14.5 9.1 11.4 1 14.1 8.4 139 6 133 165 3.8 0 4.3 3.3 05/08/2006 16:50:00 12.3 1.1 14.5 9.1 12.3 1.2 14.5 8.8 12.1 1.2 14.9 8.4 142 5 145 165 3.6 0 3.8 3.5 05/08/2006 17:00:00 11.3 1.2 14.9 8.8 11.3 1.2 14.9 8.8 11.2 1.2 14.9 8.4 138 6 144 165 3.8 0 4.3 3.5 05/08/2006 17:10:00 11.9 1.4 15.3 7.6 12 1.4 15.3 8 11.7 1.4 15.3 8.4 137 6 144 165 4.1 0.1 4.3 3.5 05/08/2006 17:20:00 13.3 1.3 16.4 10.3 13.5 1.3 16.4 10.7 13.2 1.4 16.8 8.8 131 8 135 165 4.1 0.1 4.3 3.5 05/08/2006 17:30:00 12.4 1.2 15.6 9.1 12.5 1.2 16.1 8.8 12.2 1.4 16.4 8.4 134 7 135 165 3.4 0.3 3.8 2.8 05/08/2006 17:40:00 10.2 1 12.6 8 10.2 0.9 12.6 8 10.1 1 12.6 7.2 136 7 129 165 3 0 3.3 2.8 05/08/2006 17:50:00 10 0.9 12.6 7.6 10.1 1 13 7.6 9.6 1 12.2 6.5 131 12 128 165 3 0.1 3.3 2.6 05/08/2006 18:00:00 9.3 0.8 11.1 7.2 9.3 0.8 11.1 7.2 9.3 0.9 11.1 7.2 137 5 139 165 3 0.1 3 2.6 05/08/2006 18:10:00 7 0.8 9.5 5.7 7.1 0.8 9.9 5.3 6.9 0.9 9.5 4.9 131 8 142 165 2.9 0 3 2.6 05/08/2006 18:20:00 5.9 0.8 7.6 4.2 5.9 0.8 7.6 4.2 5.9 0.8 7.6 3.8 130 7 128 165 2.8 0 3 2.3 05/08/2006 18:30:00 6.8 1.5 11.5 4.2 6.9 1.5 11.5 4.6 6.6 1.3 11.1 4.2 119 10 128 165 2.9 0.1 3.5 2.6 05/08/2006 18:40:00 11.4 1.7 14.9 6.8 11.7 1.7 15.6 7.2 11 1.8 14.1 6.1 110 9 105 165 3.6 0.1 3.8 3.3 05/08/2006 18:50:00 11.3 1.3 14.5 8.4 11.6 1.3 14.9 8.8 11.1 1.3 14.9 8.4 115 7 115 165 3.8 0 4 3.5 05/08/2006 19:00:00 11.6 1.2 14.5 8.4 11.8 1.3 14.5 8.4 11.1 1.5 14.9 7.6 111 8 110 165 3.6 0 3.8 3.5 05/08/2006 19:10:00 11.3 1 13.7 8.8 11.5 1 13.7 8.8 10.8 1.2 13.7 7.2 108 6 98 165 3.5 0 3.5 3.5 05/08/2006 19:20:00 10.4 1.3 13.3 7.2 10.6 1.3 13.3 7.2 9.8 1.4 13 6.5 106 7 101 165 3.6 0 3.5 3.3 05/08/2006 19:30:00 11.8 1 14.9 8.4 12 1 14.5 8.4 11.1 1.2 14.1 8 103 5 111 165 3.5 0 3.5 3.3 05/08/2006 19:40:00 10.9 1.4 14.1 6.8 11.1 1.3 14.5 7.2 10.3 1.5 13.7 6.5 104 6 106 165 3.4 0 3.5 3.3 05/08/2006 19:50:00 10.7 1 13 6.8 11 1 13.3 6.8 10.2 1.3 12.2 5.3 107 4 100 165 3.1 0.1 3.3 2.8 05/08/2006 20:00:00 9.9 1.4 13.3 6.5 10.2 1.4 13.7 6.5 9.4 1.4 12.6 5.7 105 8 99 165 3 0 3.3 2.8 05/08/2006 20:10:00 9.9 1.3 12.2 5.3 10.2 1.3 12.6 6.1 9.4 1.3 11.8 5.3 104 7 106 165 2.9 0 3 2.8 05/08/2006 20:20:00 9.3 1.5 12.6 6.1 9.5 1.5 13 6.1 8.7 1.5 12.6 4.9 97 7 94 165 2.8 0 2.8 2.6 05/08/2006 20:30:00 8.9 1.2 11.8 5.3 9.2 1.2 12.2 6.1 8.5 1.3 12.6 5.7 95 7 94 165 2.7 0 2.8 2.6 05/08/2006 20:40:00 8.4 1 10.7 5.7 8.7 1 11.1 5.7 8 1 10.3 5.3 93 7 90 165 2.5 0.1 2.8 2.3 05/08/2006 20:50:00 7.1 1.2 9.5 3.4 7.4 1.2 10.3 3.8 6.8 1.1 9.5 4.2 99 9 100 165 2.6 0.1 2.8 1.8 05/08/2006 21:00:00 6.7 1.1 9.5 4.2 6.9 1.1 9.5 4.2 6.4 1.1 9.5 3.8 94 11 81 165 2.4 0 2.6 2.3 05/08/2006 21:10:00 7.5 1.1 10.3 4.6 7.8 1.1 10.7 4.9 7.2 1.1 10.3 4.2 93 7 98 165 2.2 0 2.6 2.1 05/08/2006 21:20:00 6.6 1.3 9.1 3.4 6.8 1.3 9.5 3.4 6.5 1.2 9.1 3.4 91 9 102 165 2.5 0 2.8 2.3 05/08/2006 21:30:00 6.4 1 8.8 3.8 6.6 1 8.8 4.2 6.2 1 8.8 3.8 95 9 94 165 2.6 0.1 2.8 2.3 05/08/2006 21:40:00 6.4 1 9.1 3.4 6.6 1.1 9.5 3.4 6.2 1 8.4 3.4 86 12 89 165 2.6 0 2.8 2.1 05/08/2006 21:50:00 8.2 0.9 10.7 5.7 8.5 0.9 10.7 5.7 8 0.9 10.3 5.7 99 14 106 165 2.8 0 3 2.1 05/08/2006 22:00:00 7.2 1 9.9 4.6 7.3 1 9.9 4.6 7 1 9.5 3.8 108 9 118 165 2.6 0.1 2.8 1.8 05/08/2006 22:10:00 7.6 1.2 10.3 4.2 7.9 1.2 10.7 4.9 7.2 1.2 9.9 4.2 102 8 102 165 2.7 0 2.8 2.1 05/08/2006 22:20:00 7.9 1.1 10.7 5.3 8.1 1.1 10.7 4.9 7.7 1.1 10.3 4.6 106 5 111 165 2.9 0 3 2.3 05/08/2006 22:30:00 8 1.2 10.3 4.9 8.2 1.3 10.3 4.9 7.6 1.2 9.5 4.6 104 8 102 165 2.9 0.1 3 2.6 05/08/2006 22:40:00 8 1.1 11.5 5.7 8.2 1.1 11.5 6.1 7.8 1 11.5 5.7 112 8 116 165 3 0.1 3.3 2.6 05/08/2006 22:50:00 7 0.9 8.8 4.6 7.1 1 9.1 4.6 6.8 1 8.8 4.2 120 7 111 165 3 0.1 3.3 2.6 05/08/2006 23:00:00 4.9 1.1 7.6 2.3 5.1 1.1 7.6 2.3 4.9 1 8 2.6 117 9 119 165 3 0 3.3 2.8 05/08/2006 23:10:00 6.9 1.3 9.1 2.6 7.1 1.3 9.5 3 6.8 1.3 9.5 2.6 106 8 105 165 3.3 0.1 3.5 2.8 05/08/2006 23:20:00 7.6 0.8 9.9 6.1 7.9 0.8 9.9 6.1 7.3 0.9 9.5 4.9 107 6 106 165 3.6 0 3.8 3.5 05/08/2006 23:30:00 6.9 0.6 9.5 5.7 7.1 0.6 9.9 5.7 6.8 0.7 9.1 4.6 108 5 103 165 3.6 0 3.8 3.5 05/08/2006 23:40:00 5.7 0.8 7.6 3.4 5.9 0.8 7.6 3.8 5.5 0.8 7.2 3.4 93 10 110 165 3.6 0 3.8 3.5 05/08/2006 23:50:00 6.8 1.5 10.7 3.4 6.9 1.5 11.1 3.4 6.7 1.5 10.7 3 88 22 84 165 3.9 0 4.3 3.8 05/09/2006 00:00:00 7.4 1.5 11.1 3.8 7.5 1.6 11.1 3.8 7.2 1.5 11.8 3.4 119 14 102 165 4.1 0.1 4.3 3.8 05/09/2006 00:10:00 6.2 1.5 10.3 3.8 6.3 1.5 10.3 3.8 5.8 1.5 9.5 3.4 117 11 102 165 4.2 0 4.5 4 05/09/2006 00:20:00 4.7 1.9 9.9 1.1 4.6 2.1 10.3 1.1 4.7 1.7 9.5 1.5 147 26 121 165 4.1 0.1 4.5 3.8 05/09/2006 00:30:00 5.1 0.6 7.2 3.8 5.1 0.6 7.2 3.4 5.2 0.5 6.8 3.4 162 8 162 165 3.5 0.1 3.8 3.3 05/09/2006 00:40:00 5.4 0.8 7.6 3.4 5.4 0.8 7.2 3.4 5.6 0.8 7.6 3.8 148 15 162 165 3.3 0 3.5 3.3 05/09/2006 00:50:00 4.9 1 8.4 2.6 4.9 1 8.4 2.6 5.1 1 7.6 3 140 12 148 165 3.2 0 3.5 3 05/09/2006 01:00:00 5.3 0.8 7.2 3.4 5.3 0.8 7.2 3.4 5.5 0.7 7.2 4.2 138 11 128 165 3.3 0 3.5 3.3 05/09/2006 01:10:00 4.4 0.7 6.8 3 4.5 0.7 6.5 3 4.5 0.6 6.5 3 129 11 121 165 3.4 0 3.5 3.3 05/09/2006 01:20:00 5.2 0.8 7.2 2.3 5.3 0.9 7.6 2.6 5.1 0.8 7.2 1.9 116 9 124 165 3.5 0.1 3.8 3.3 05/09/2006 01:30:00 5.2 0.5 6.5 4.2 5.4 0.4 6.5 4.2 5.2 0.5 6.5 3.4 115 6 103 165 3.6 0 3.8 3.3 05/09/2006 01:40:00 5.2 0.5 6.5 4.2 5.4 0.5 6.5 4.2 5.3 0.5 6.8 3.8 117 6 116 165 3.7 0 3.8 3.5 05/09/2006 01:50:00 5.8 0.5 7.2 4.6 6 0.5 7.6 4.9 5.8 0.6 7.2 4.6 116 4 111 165 3.9 0 4 3.5 05/09/2006 02:00:00 6.4 0.7 8 4.2 6.6 0.8 8.4 3.8 6.5 0.8 8.4 4.2 130 23 122 165 3.9 0 4.3 3.3 05/09/2006 02:10:00 6.3 0.8 8 4.6 6.2 0.7 8 4.2 6.3 0.6 7.6 4.6 149 7 154 165 3.3 0 3.5 2.8 05/09/2006 02:20:00 5.4 0.5 6.8 3.8 5.4 0.5 6.8 4.2 5.4 0.5 6.8 3.8 143 7 130 165 3.5 0 3.8 3 05/09/2006 02:30:00 5.8 0.9 8.4 4.2 5.9 0.9 8.4 3.8 5.9 0.8 8 3.8 137 8 140 165 3.6 0 3.8 3 05/09/2006 02:40:00 7.2 0.8 9.1 4.9 7.2 0.8 9.1 4.9 7.3 0.7 9.1 5.3 139 7 133 165 3.6 0 3.8 3.3 05/09/2006 02:50:00 6.8 0.6 8 4.9 6.8 0.6 8 4.9 6.8 0.7 8.4 4.6 139 7 158 165 3.5 0 3.8 3.3 05/09/2006 03:00:00 6.1 0.7 7.6 4.2 6.1 0.7 7.6 4.2 6.1 0.6 7.6 4.6 145 7 140 165 3.6 0 3.8 3.3 05/09/2006 03:10:00 5.7 0.8 8.8 3.8 5.8 0.8 8.8 3.8 5.9 0.6 8 3.8 140 9 125 165 3.6 0 3.8 3.3 05/09/2006 03:20:00 5.9 0.6 6.8 4.2 5.9 0.5 7.2 4.6 5.9 0.5 7.6 4.6 139 8 141 165 3.6 0 3.8 3.3 05/09/2006 03:30:00 5.9 1 9.5 3.8 6 1 9.5 3.8 5.9 1 9.5 4.2 138 10 135 165 3.7 0 3.8 3.5 05/09/2006 03:40:00 5.8 1 8.4 3.8 5.9 1 8.4 3.8 5.9 0.9 8 3.4 132 9 134 165 3.8 0 4 3.5 05/09/2006 03:50:00 7.3 0.9 10.3 5.3 7.4 0.9 10.3 5.3 7.3 1 11.1 4.9 123 9 112 165 4 0 4.3 3.8 05/09/2006 04:00:00 7.8 0.7 9.1 5.3 8 0.7 9.5 5.7 7.9 0.8 9.5 5.3 127 6 122 165 4.1 0 4.3 3.8 05/09/2006 04:10:00 9.2 1.7 11.8 5.7 9.4 1.7 12.2 6.1 9 1.7 12.2 5.7 117 7 116 165 4.1 0 4.3 4 05/09/2006 04:20:00 8.7 1 11.1 4.9 8.9 1.1 11.5 4.6 8.5 1.1 11.1 4.6 114 6 108 165 4 0 4.3 4 05/09/2006 04:30:00 9.1 1 11.5 5.7 9.4 1.1 11.8 5.7 8.9 1.1 11.5 5.7 117 6 123 165 4.1 0 4.3 4 05/09/2006 04:40:00 8 0.9 10.7 5.7 8.2 0.9 10.7 6.1 7.8 1 10.7 5.7 116 7 114 165 4.1 0 4.3 4 05/09/2006 04:50:00 9.9 1 13 8 10.1 1.1 13.3 8 9.7 1.2 13.3 6.8 120 8 115 165 3.8 0 4.3 3.5 05/09/2006 05:00:00 7.9 0.8 10.3 6.1 8.1 0.8 10.3 6.1 7.8 0.8 9.9 5.7 122 6 121 165 3.7 0 3.8 3.5 05/09/2006 05:10:00 8.3 0.8 10.7 6.5 8.5 0.8 11.1 6.5 8.1 0.8 11.1 6.1 115 6 107 165 4 0 4 3.8 05/09/2006 05:20:00 8.4 0.8 10.7 6.5 8.6 0.8 11.1 6.5 8.2 1 11.5 6.1 118 6 109 165 3.8 0 4 3.8 05/09/2006 05:30:00 7.8 0.6 9.1 6.5 8 0.6 9.5 6.5 7.7 0.6 9.1 4.9 114 5 106 165 3.8 0 3.8 3.5 05/09/2006 05:40:00 7.5 0.7 9.5 6.1 7.7 0.7 9.5 5.7 7.3 0.7 9.5 5.3 118 7 113 165 3.8 0 4 3.5 05/09/2006 05:50:00 7.5 0.7 9.1 5.7 7.7 0.7 9.1 5.7 7.3 0.7 9.1 5.7 118 5 128 165 3.9 0 4 3.5 05/09/2006 06:00:00 7.7 0.7 9.5 5.7 7.9 0.7 9.9 5.3 7.6 0.8 9.5 4.9 114 5 109 165 4 0 4.3 3.5 05/09/2006 06:10:00 7.4 0.7 8.8 5.7 7.6 0.7 9.1 6.1 7.3 0.7 9.1 5.7 117 6 121 165 3.9 0 4 3.5 05/09/2006 06:20:00 6.7 1 9.1 4.2 6.9 1 9.5 4.6 6.6 0.9 8.8 3.8 120 8 122 165 3.9 0 4.3 3.5 05/09/2006 06:30:00 7.1 0.8 8.4 4.6 7.3 0.8 9.1 4.6 6.8 0.8 8.8 4.6 113 7 115 165 3.9 0 4 3.5 05/09/2006 06:40:00 6.8 0.6 8.4 4.9 7 0.6 8.4 5.3 6.5 0.6 8.4 4.6 106 5 104 165 3.8 0 4 3.5 05/09/2006 06:50:00 6.2 0.8 7.6 4.2 6.4 0.8 8 4.2 5.8 0.8 7.6 3.8 108 5 99 165 3.8 0 3.8 3.5 05/09/2006 07:00:00 5.8 0.6 7.2 3.8 6 0.6 7.6 4.6 5.6 0.7 7.2 3.8 108 5 110 165 3.8 0 4 3.5 05/09/2006 07:10:00 5.7 0.4 6.5 4.6 5.9 0.4 6.8 4.6 5.5 0.5 6.8 3.8 103 5 99 165 3.8 0 4 3.5 05/09/2006 07:20:00 6.2 0.7 8 3 6.4 0.7 8 3.8 5.9 0.7 8 3.8 107 5 109 165 3.9 0 4 3.5 05/09/2006 07:30:00 6.5 0.6 8.4 4.9 6.7 0.6 8.4 4.6 6.3 0.7 8 4.2 107 6 106 165 4 0 4.3 3.5 05/09/2006 07:40:00 6.4 0.8 8.8 4.6 6.6 0.8 8.8 4.6 6.2 0.8 8 4.6 108 8 108 165 4 0 4.3 3.8 05/09/2006 07:50:00 6.9 0.8 8.8 4.9 7.1 0.8 8.4 5.3 6.6 0.9 8.4 4.2 112 5 117 165 4 0 4.3 3.8 05/09/2006 08:00:00 6 0.8 7.6 3.4 6.2 0.8 8 3.4 5.8 0.8 7.6 3.8 110 6 105 165 4 0 4.3 3.8 05/09/2006 08:10:00 5.5 0.6 6.8 3.4 5.6 0.6 7.2 3.4 5.3 0.7 6.8 3.4 107 5 104 165 3.8 0 4 3.8 05/09/2006 08:20:00 5.7 0.6 6.8 3.8 5.9 0.6 7.2 3.8 5.4 0.7 6.8 3.4 101 7 101 165 3.8 0 4 3.5 05/09/2006 08:30:00 6.4 0.5 7.2 4.6 6.7 0.5 7.6 4.6 6.3 0.6 7.6 4.2 106 6 106 165 4 0.1 4.3 3.5 05/09/2006 08:40:00 6.4 0.8 8 3.4 6.5 0.8 8.4 3.8 6.2 0.7 8 4.6 115 7 110 165 4 0.1 4.3 3.5 05/09/2006 08:50:00 6.8 0.8 8.8 4.2 7 0.8 8.8 3.8 6.6 0.8 8.4 4.2 102 7 106 165 4 0 4.3 3.8 05/09/2006 09:00:00 6.9 0.6 8.4 4.6 7.1 0.6 8.4 4.9 6.7 0.8 8.4 4.6 107 6 109 165 3.8 0 4.3 3.5 05/09/2006 09:10:00 6.2 0.8 8 4.2 6.4 0.8 8.4 4.2 6 0.8 7.6 4.2 95 7 88 165 3.5 0 3.8 3.3 05/09/2006 09:20:00 5.8 0.9 7.6 3 5.9 0.9 7.6 3 5.4 0.9 7.6 3 97 7 97 165 3.3 0 3.5 3.3 05/09/2006 09:30:00 5.9 0.8 7.6 3.8 6.1 0.8 7.6 3.4 5.7 0.9 7.6 3.4 94 8 86 165 3.5 0 3.5 3.3 05/09/2006 09:40:00 4.7 0.8 6.1 3 4.8 0.9 6.5 2.6 4.7 0.8 6.5 3.4 79 8 89 165 3.6 0 3.8 3.3 05/09/2006 09:50:00 4.3 0.7 6.1 2.6 4.5 0.7 6.5 2.6 4.4 0.7 6.5 2.6 77 9 84 165 3.6 0 3.8 3.5 05/09/2006 10:00:00 3.7 0.6 5.3 2.3 3.9 0.6 5.3 2.3 3.9 0.5 5.3 2.6 67 8 70 165 3.6 0 3.8 3.3 05/09/2006 10:10:00 4.3 0.6 6.1 2.6 4.4 0.6 6.1 3 4.2 0.5 5.7 3 71 9 65 165 3.6 0 3.8 3.3 05/09/2006 10:20:00 4.8 0.8 6.5 2.6 4.9 0.9 6.5 3 4.9 0.8 6.8 2.6 77 8 73 165 3.6 0 3.8 3.5 05/09/2006 10:30:00 3.7 0.5 4.9 2.6 3.9 0.5 5.3 2.6 3.8 0.5 4.9 2.3 79 8 81 165 3.5 0 3.5 3.3 05/09/2006 10:40:00 3.4 0.6 4.9 1.9 3.5 0.6 5.3 2.3 3.5 0.5 4.9 2.3 80 8 87 165 3.3 0.1 3.5 2.8 05/09/2006 10:50:00 3.8 0.5 4.9 2.6 3.9 0.5 4.9 2.6 3.9 0.4 4.9 3 76 6 84 165 3 0.1 3.3 2.6 05/09/2006 11:00:00 3.8 0.5 4.9 2.3 3.8 0.5 4.9 2.3 3.8 0.5 4.6 2.6 68 7 74 165 3.3 0.2 3.8 2.8 05/09/2006 11:10:00 3 0.7 5.3 1.9 3 0.7 4.9 1.9 3 0.7 4.9 1.5 59 10 45 165 3.6 0 3.8 3.3 05/09/2006 11:20:00 3.7 0.6 6.1 2.6 3.6 0.7 6.1 2.3 3.4 0.6 4.9 2.3 59 13 52 165 3.9 0.2 4.3 3.3 05/09/2006 11:30:00 4.6 0.7 6.5 2.6 4.7 0.8 6.8 2.6 4.7 0.7 6.8 3 70 12 63 165 4.4 0 4.8 3.8 05/09/2006 11:40:00 4.1 1.1 7.2 2.3 4.2 1.1 7.6 2.3 4.2 1 7.6 2.6 65 12 74 165 4.4 0 4.8 4 05/09/2006 11:50:00 5.2 1 8.4 2.6 5.3 1 8 3 5.3 1 8.4 2.6 62 11 81 165 4.6 0.2 5 4 05/09/2006 12:00:00 5.7 1.1 8.4 2.6 5.7 1.2 8.4 3 5.6 1.1 8.4 3.4 51 8 48 165 4.4 0.1 4.8 4.3 05/09/2006 12:10:00 4.8 1.1 7.2 2.3 4.9 1.1 7.6 2.3 4.8 1.1 7.6 2.6 56 11 46 165 4.4 0.2 4.8 4 05/09/2006 12:20:00 5.6 0.9 8 3.4 5.7 1 8 3.4 5.5 0.9 8.4 3.4 58 10 56 165 4.3 0.1 4.8 3.8 05/09/2006 12:30:00 5.7 1.1 8.8 3 5.8 1.1 8.8 3 5.6 1 8.4 3.4 57 9 50 165 4.1 0.1 4.5 3.5 05/09/2006 12:40:00 5.1 0.8 7.2 3 5.1 0.9 6.8 3 5.1 0.8 7.2 3.4 77 13 81 165 4.4 0.2 4.8 3.8 05/09/2006 12:50:00 5.7 0.6 7.2 3.8 5.8 0.7 7.2 3.8 5.7 0.7 7.2 3.8 123 13 96 165 4.2 0.2 4.8 3.5 05/09/2006 13:00:00 5 0.8 7.2 3.4 5 0.8 7.2 3.4 5 0.8 7.2 3 130 6 130 165 4 0 4.3 3.5 05/09/2006 13:10:00 4.8 0.6 6.5 3 4.9 0.7 6.5 3.4 4.8 0.6 6.1 3.4 118 8 122 165 4.1 0.1 4.3 3.5 05/09/2006 13:20:00 5.1 0.5 6.8 3.8 5.1 0.6 6.8 3.8 5.1 0.5 6.5 3.4 118 6 129 165 4.1 0 4.3 3.8 05/09/2006 13:30:00 5.2 0.4 6.1 4.2 5.3 0.4 6.1 4.2 5.1 0.5 6.5 3.8 123 6 127 165 4 0 4.3 3.8 05/09/2006 13:40:00 4.6 0.5 5.7 2.6 4.7 0.5 5.7 3.4 4.6 0.4 5.7 3 107 6 106 165 4.2 0.1 4.5 3.8 05/09/2006 13:50:00 4.4 0.6 6.1 3 4.5 0.6 6.5 3 4.5 0.6 6.1 3 112 7 110 165 4.4 0 4.8 4 05/09/2006 14:00:00 5.3 0.7 6.8 3.4 5.4 0.7 7.2 3.4 5.1 0.6 6.8 3.4 110 6 118 165 4.1 0.2 4.5 3.5 05/09/2006 14:10:00 4.8 0.5 5.7 3.4 4.9 0.5 5.7 3.4 4.7 0.6 5.7 3.4 113 5 115 165 4.1 0.1 4.5 3.8 05/09/2006 14:20:00 4 0.7 5.3 2.3 4 0.7 5.7 2.3 4 0.7 6.1 1.9 107 9 116 165 4.5 0 4.8 4.3 05/09/2006 14:30:00 4.2 0.5 5.3 3 4.2 0.5 5.7 2.6 4.1 0.5 5.3 2.6 105 7 102 165 4.4 0.2 5 4 05/09/2006 14:40:00 4.1 0.6 6.1 2.6 4.1 0.6 6.1 2.3 4.1 0.6 5.7 2.6 100 9 94 165 4.9 0 5.2 4.5 05/09/2006 14:50:00 4.3 0.8 6.8 1.9 4.4 0.9 6.8 1.9 4.4 0.8 6.8 2.6 101 11 87 165 5.2 0.2 5.7 4.8 05/09/2006 15:00:00 4.6 0.8 6.8 2.6 4.7 0.8 6.8 3 4.6 0.8 7.2 3 101 12 102 165 5.1 0.1 5.5 4.5 05/09/2006 15:10:00 4.7 0.8 7.2 2.6 4.8 0.9 7.2 2.6 4.6 0.8 6.8 1.9 101 11 88 165 5.1 0.1 5.5 4.8 05/09/2006 15:20:00 4 0.8 6.5 1.9 4 0.9 6.8 2.3 4 0.8 6.8 2.3 97 12 98 165 5 0.2 5.5 4.8 05/09/2006 15:30:00 4.1 0.7 5.7 2.3 4.1 0.8 6.1 1.9 4.1 0.7 6.1 2.3 106 10 118 165 5.5 0 5.7 5.2 05/09/2006 15:40:00 3.8 0.7 5.7 1.9 3.9 0.7 5.7 1.5 4 0.7 6.1 2.3 102 11 103 165 5.5 0.1 5.7 5 05/09/2006 15:50:00 3.6 0.7 5.3 1.9 3.5 0.8 5.3 1.5 3.5 0.7 5.3 1.9 92 18 102 165 5.7 0 6 5.5 05/09/2006 16:00:00 3.9 0.7 6.1 1.9 3.9 0.8 6.5 1.9 3.8 0.9 5.7 1.1 98 10 102 165 5.7 0 6 5.5 05/09/2006 16:10:00 3.5 0.5 4.9 2.3 3.6 0.5 4.9 1.9 3.5 0.5 4.9 1.9 97 13 107 165 5.7 0.1 6 5.5 05/09/2006 16:20:00 4.1 0.7 6.5 2.3 4.2 0.7 6.5 2.3 4.2 0.7 5.7 2.3 101 13 84 165 5.4 0 5.7 5.2 05/09/2006 16:30:00 3.9 0.7 5.7 2.3 3.9 0.7 5.7 2.3 3.9 0.7 5.7 2.3 95 17 100 165 5.2 0.2 5.7 4.8 05/09/2006 16:40:00 3.3 0.8 5.3 1.1 3.3 0.8 5.3 1.1 3.3 0.7 4.9 1.5 64 11 60 165 4.8 0.1 5.2 4.8 05/09/2006 16:50:00 3.3 0.6 4.6 1.5 3.3 0.6 4.6 1.5 3.3 0.7 4.9 1.9 69 15 54 165 4.6 0 4.8 4.5 05/09/2006 17:00:00 2.9 1 5.7 1.1 2.9 1 5.7 1.1 3.1 0.8 4.9 1.5 56 11 52 165 4.1 0.1 4.5 3.8 05/09/2006 17:10:00 3.5 0.6 4.9 1.9 3.6 0.6 4.9 1.9 3.7 0.6 4.9 2.3 70 8 75 165 4.4 0.3 5 3.8 05/09/2006 17:20:00 2.9 0.5 4.2 1.5 3 0.5 4.6 1.5 3 0.5 4.6 1.9 65 9 67 165 4.8 0.2 5 4.3 05/09/2006 17:30:00 2.4 0.7 4.2 0.7 2.4 0.7 4.2 0.7 2.6 0.6 4.2 1.1 64 12 62 165 4.6 0.1 5 4.3 05/09/2006 17:40:00 3.3 0.5 4.2 1.9 3.4 0.5 4.6 2.3 3.2 0.5 4.2 1.9 55 9 39 165 4.1 0.1 4.5 3.8 05/09/2006 17:50:00 3.6 0.7 5.3 1.9 3.6 0.7 5.3 1.9 3.6 0.6 4.9 2.3 32 12 14 165 4.1 0.1 4.3 3.8 05/09/2006 18:00:00 3.8 0.7 5.3 1.9 3.6 0.8 5.3 1.1 3.8 0.7 5.3 1.9 22 8 28 165 4 0.2 4.3 3.5 05/09/2006 18:10:00 4.1 0.4 5.3 3 3.9 0.5 4.9 2.3 4.2 0.5 5.3 2.6 21 6 28 165 3.9 0.2 4.3 3.5 05/09/2006 18:20:00 4.4 0.7 5.7 2.6 4.2 0.7 5.7 1.9 4.3 0.7 5.7 2.6 20 6 19 165 3.9 0.2 4.3 3.5 05/09/2006 18:30:00 4.4 0.7 6.1 2.6 4.3 0.8 5.7 2.6 4.5 0.7 6.1 2.6 23 8 27 165 3.9 0.2 4.3 3.3 05/09/2006 18:40:00 4 0.6 5.7 2.6 3.8 0.7 5.7 2.3 4.2 0.6 5.7 2.6 21 7 22 165 4 0.2 4.3 3.5 05/09/2006 18:50:00 2.3 0.5 3.4 0.7 2.3 0.6 3.4 0.4 2.6 0.6 3.8 0.7 22 11 15 165 4.6 0.4 5.2 3.8 05/09/2006 19:00:00 3.1 1 4.6 0.4 2.6 1 4.6 0.4 3.4 1.1 4.9 0.7 12 9 359 165 5.1 0.1 5.5 4.5 05/09/2006 19:10:00 3.8 0.6 5.3 2.3 2.7 0.7 4.6 1.1 4.1 0.5 5.3 2.6 5 8 3 165 4.7 0.2 5 4.3 05/09/2006 19:20:00 3.7 0.5 4.9 2.6 2.5 0.6 3.8 1.1 3.9 0.6 5.3 2.3 3 8 3 165 4.3 0.2 4.8 3.8 05/09/2006 19:30:00 3.5 0.5 4.6 2.3 2.8 0.7 4.2 1.1 3.8 0.6 4.9 2.6 10 8 5 165 4.1 0 4.5 3.8 05/09/2006 19:40:00 3.4 0.5 4.6 2.3 2.7 0.6 4.2 0.7 3.8 0.5 4.9 2.6 12 5 14 165 4 0.1 4.3 3.5 05/09/2006 19:50:00 3.9 0.3 4.6 3 3.4 0.6 4.6 1.1 4.1 0.4 5.3 3 17 6 5 165 3.9 0.1 4.3 3.5 05/09/2006 20:00:00 4.2 0.4 5.3 3 4 0.5 4.9 2.6 4.5 0.5 5.3 3 20 4 19 165 3.8 0 4.3 3.3 05/09/2006 20:10:00 3.8 0.3 4.2 3 3.4 0.4 4.2 2.3 4.1 0.3 4.9 3 17 4 20 165 3.6 0.1 3.8 3.3 05/09/2006 20:20:00 3.3 0.4 4.2 2.3 3 0.5 4.2 1.5 3.6 0.3 4.2 2.6 18 4 26 165 3.7 0.1 3.8 3.3 05/09/2006 20:30:00 3.5 0.5 4.6 2.3 2.8 0.6 4.2 1.1 3.8 0.5 5.3 2.6 13 6 13 165 3.7 0.1 3.8 3.3 05/09/2006 20:40:00 3.3 0.4 4.6 2.3 2.4 0.6 4.6 1.1 3.7 0.4 4.9 3 9 6 28 165 3.7 0.1 3.8 3.3 05/09/2006 20:50:00 3.6 0.4 4.6 2.3 3.3 0.6 4.6 1.5 3.7 0.5 4.6 2.6 19 7 26 165 3.7 0.1 4 3.3 05/09/2006 21:00:00 3.6 0.4 4.6 2.6 3.6 0.4 4.6 2.3 3.9 0.4 4.9 2.6 26 4 26 165 3.5 0.2 3.8 3 05/09/2006 21:10:00 3.6 0.4 4.6 3 3.4 0.5 4.6 1.9 4 0.3 4.9 3.4 21 6 22 165 3.5 0.2 3.8 2.8 05/09/2006 21:20:00 3.5 0.4 4.2 2.6 3.5 0.4 4.6 2.3 3.8 0.4 4.6 3 24 4 25 165 3.5 0.1 3.8 2.8 05/09/2006 21:30:00 3.6 0.4 4.9 2.6 3.5 0.4 4.9 2.6 3.9 0.4 4.6 2.6 22 4 22 165 3.5 0.2 3.8 3 05/09/2006 21:40:00 2.9 0.3 3.8 2.3 2.7 0.4 3.8 1.5 3.2 0.4 4.2 2.3 19 4 22 165 3.5 0.1 3.5 2.8 05/09/2006 21:50:00 2.1 0.4 3 0.7 1.5 0.6 3 0.4 2.1 0.7 3 0.4 357 20 19 165 3.5 0.1 3.5 2.8 05/09/2006 22:00:00 3 0.5 4.2 1.9 3.1 0.5 4.2 1.9 2.5 0.6 4.2 0.7 305 7 305 165 3.2 0.2 3.5 2.8 05/09/2006 22:10:00 2.8 0.3 3.4 1.9 2.9 0.3 3.4 2.3 2.4 0.4 3.4 1.1 290 10 285 165 3 0 3.3 2.8 05/09/2006 22:20:00 3.2 0.3 3.8 2.6 3.3 0.3 3.8 2.6 2.4 0.4 3.4 1.5 302 3 300 165 3 0 3.3 2.8 05/09/2006 22:30:00 2.9 0.4 3.8 2.3 3 0.4 3.8 2.3 2.3 0.4 3.4 1.1 300 3 305 165 2.9 0 3 2.8 05/09/2006 22:40:00 3.7 0.4 4.2 2.6 3.8 0.4 4.6 2.6 2.6 0.4 3.8 1.9 300 2 299 165 2.9 0 3 2.8 05/09/2006 22:50:00 3.9 0.2 4.6 3.4 4 0.2 4.6 3.4 3 0.5 4.6 1.5 297 4 291 165 2.9 0 2.8 2.6 05/09/2006 23:00:00 4.2 0.3 4.9 3.4 4.2 0.3 4.9 3.4 3 0.4 3.8 2.3 302 2 302 165 2.9 0 3 2.8 05/09/2006 23:10:00 3.9 0.3 4.6 3 3.9 0.3 4.6 3 3.5 0.5 4.9 1.9 307 6 306 165 2.8 0 3 2.6 05/09/2006 23:20:00 3.3 0.4 4.6 1.9 3.3 0.4 4.6 2.3 3 0.6 4.2 1.5 308 9 308 165 2.8 0 3 2.6 05/09/2006 23:30:00 2.8 0.3 3.4 1.9 2.8 0.3 3.4 1.9 2.6 0.4 3.8 1.5 311 7 327 165 2.8 0 3 2.6 05/09/2006 23:40:00 1.8 0.5 2.6 0.4 1.8 0.5 3 0.4 1.8 0.4 2.6 0.4 307 13 307 165 2.9 0 3.3 2.8 05/09/2006 23:50:00 1.3 0.4 2.3 0.4 1.4 0.5 2.6 0.4 1.2 0.5 2.3 0.4 291 10 332 165 3 0 3.3 2.8 05/10/2006 00:00:00 1.6 0.5 2.6 0.4 1.7 0.6 3 0.4 1.3 0.5 2.6 0.4 298 7 294 165 2.9 0 3 2.8 05/10/2006 00:10:00 1.5 0.5 2.3 0.4 1.4 0.5 2.3 0.4 1.4 0.4 2.6 0.4 311 8 296 165 2.8 0 2.8 2.3 05/10/2006 00:20:00 2.4 0.9 4.2 0.7 2.4 0.9 4.2 0.7 1.9 0.7 3.4 0.4 307 9 305 165 2.8 0 3 2.3 05/10/2006 00:30:00 3.7 0.5 4.9 2.6 3.7 0.5 4.9 2.3 3 0.4 4.2 1.9 303 5 307 165 3 0.1 3.3 2.3 05/10/2006 00:40:00 4.2 0.5 5.7 3 4.2 0.5 5.7 3 3.5 0.6 5.3 2.3 298 5 297 165 3 0 3.3 2.6 05/10/2006 00:50:00 4.3 0.6 5.7 3 4.3 0.5 5.7 3 3.5 0.5 4.9 2.3 300 6 302 165 3 0.1 3.3 2.6 05/10/2006 01:00:00 3.5 0.6 4.9 2.6 3.6 0.5 4.9 2.6 3 0.5 4.6 1.5 293 6 291 165 2.9 0 3 2.6 05/10/2006 01:10:00 3.5 0.5 4.6 2.3 3.6 0.5 4.6 2.6 3 0.5 4.6 1.9 293 5 290 165 3 0.1 3.3 2.6 05/10/2006 01:20:00 2.1 0.9 4.2 0.4 2.2 1 4.2 0.4 1.7 0.8 3.4 0.4 286 8 301 165 3 0.1 3.3 2.6 05/10/2006 01:30:00 1.3 0.5 2.3 0.4 1.4 0.5 2.6 0.4 0.9 0.5 2.3 0.4 286 8 285 165 3 0.1 3.3 2.6 05/10/2006 01:40:00 1 0.5 1.9 0.4 1 0.5 1.9 0.4 0.9 0.5 1.9 0.4 284 4 285 165 3 0.1 3.3 2.6 05/10/2006 01:50:00 2.2 0.4 3 1.1 2.3 0.4 3 1.1 2.2 0.4 3 1.1 284 6 280 165 3 0.1 3.3 2.6 05/10/2006 02:00:00 2.4 0.3 3 1.9 2.5 0.3 3 1.9 2 0.4 3 1.1 292 4 286 165 3 0.1 3.3 2.6 05/10/2006 02:10:00 2.1 0.3 2.6 1.5 2.2 0.3 3 1.5 1.6 0.4 2.6 0.7 299 4 301 165 3 0.1 3 2.6 05/10/2006 02:20:00 2.3 0.4 3.4 1.5 2.5 0.4 3.4 1.5 2.1 0.7 3.4 0.7 286 7 277 165 2.9 0 3 2.6 05/10/2006 02:30:00 1.8 0.7 3 0.4 2 0.8 3 0.4 1.9 0.8 3.4 0.4 277 5 282 165 2.9 0 3 2.8 05/10/2006 02:40:00 0.9 0.4 1.5 0.4 1 0.5 1.9 0.4 0.9 0.5 1.9 0.4 243 19 251 165 2.9 0 3 2.8 05/10/2006 02:50:00 0.7 0.4 1.5 0.4 0.7 0.4 1.9 0.4 1 0.4 1.9 0.4 223 8 219 165 3 0 3.3 2.8 05/10/2006 03:00:00 0.4 0.1 1.1 0.4 0.4 0 0.4 0.4 0.5 0.2 1.5 0.4 231 0 231 165 3.2 0 3.3 3 05/10/2006 03:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 231 0 165 165 3.2 0 3.3 3 05/10/2006 03:20:00 0.4 0.1 1.1 0.4 0.4 0 0.7 0.4 0.4 0.2 1.9 0.4 163 29 180 165 3.1 0 3.3 2.8 05/10/2006 03:30:00 0.4 0.1 1.1 0.4 0.4 0 0.7 0.4 0.4 0 0.4 0.4 149 3 164 165 3 0 3.3 2.8 05/10/2006 03:40:00 0.5 0.2 1.1 0.4 0.4 0 0.7 0.4 0.4 0.2 1.5 0.4 162 4 164 165 2.9 0 3.3 2.8 05/10/2006 03:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 156 0 165 165 2.8 0 3 2.6 05/10/2006 04:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 82 58 165 165 2.7 0 2.8 2.6 05/10/2006 04:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 5 0 165 165 2.7 0 2.8 2.6 05/10/2006 04:20:00 0.4 0.2 1.5 0.4 0.4 0.3 1.9 0.4 0.4 0.1 1.1 0.4 15 11 26 165 2.7 0 2.8 2.6 05/10/2006 04:30:00 0.7 0.3 1.5 0.4 0.7 0.3 1.5 0.4 0.8 0.3 1.5 0.4 31 10 19 165 2.8 0 2.8 2.6 05/10/2006 04:40:00 0.8 0.2 1.5 0.4 0.5 0.2 1.1 0.4 0.9 0.3 1.5 0.4 17 5 18 165 2.7 0 2.8 2.3 05/10/2006 04:50:00 0.8 0.3 1.1 0.4 0.6 0.3 1.1 0.4 0.9 0.3 1.5 0.4 19 3 25 165 2.7 0 2.8 2.1 05/10/2006 05:00:00 0.8 0.3 1.5 0.4 0.6 0.3 1.5 0.4 0.6 0.3 1.5 0.4 26 11 18 165 2.7 0 2.8 2.1 05/10/2006 05:10:00 2 0.5 3 0.7 2 0.6 3 0.7 1.6 0.7 3 0.4 66 18 71 165 2.9 0 3 2.1 05/10/2006 05:20:00 2.1 0.5 3 0.4 2.1 0.5 3.4 0.4 2.1 0.4 3 1.1 72 11 91 165 3 0 3.3 2.6 05/10/2006 05:30:00 2.7 1 4.6 0.7 2.6 1 4.6 0.7 2.7 1 4.9 0.7 54 22 31 165 3 0 3.3 2.6 05/10/2006 05:40:00 2.9 0.3 3.8 2.3 2.8 0.3 3.8 2.3 2.9 0.4 4.2 2.3 42 7 48 165 2.6 0.1 2.8 1.8 05/10/2006 05:50:00 2.6 0.2 3 2.3 2.3 0.2 2.6 1.9 2.6 0.2 3 2.3 29 3 27 165 2.6 0 2.8 2.1 05/10/2006 06:00:00 2.8 0.2 3.4 2.3 2.6 0.3 3.4 1.9 2.8 0.3 3.4 2.3 28 6 32 165 2.7 0 3 2.3 05/10/2006 06:10:00 2.9 0.3 3.4 2.3 2.8 0.4 3.4 1.9 3 0.3 3.8 2.3 25 3 29 165 3 0.1 3.3 2.8 05/10/2006 06:20:00 3 0.3 3.8 2.3 3 0.4 3.8 2.3 3.1 0.3 4.2 2.3 30 6 26 165 3.3 0 3.5 3 05/10/2006 06:30:00 3.6 0.3 4.2 2.6 3.5 0.3 4.2 2.6 3.7 0.4 4.6 2.6 34 4 34 165 3.3 0 3.5 2.8 05/10/2006 06:40:00 3.6 0.4 4.6 2.6 3.7 0.4 4.6 2.6 3.8 0.4 4.6 3 31 3 31 165 3.3 0 3.5 2.8 05/10/2006 06:50:00 3 0.2 3.8 2.6 3 0.3 3.4 2.3 3.2 0.2 3.8 2.6 30 3 31 165 3.5 0 3.5 3.3 05/10/2006 07:00:00 3.2 0.4 3.8 2.3 3.3 0.4 4.2 2.3 3.4 0.4 4.2 2.6 35 5 32 165 3.4 0 3.5 3 05/10/2006 07:10:00 2.8 0.5 3.8 1.9 2.8 0.5 3.8 1.5 2.9 0.5 4.2 1.9 38 12 35 165 3.4 0 3.5 3.3 05/10/2006 07:20:00 3.1 0.8 5.7 1.1 2.2 0.8 4.9 0.4 3 0.6 4.9 1.5 4 10 16 165 3.5 0 3.8 3.3 05/10/2006 07:30:00 4.7 1 6.8 1.5 3.9 1.1 6.5 1.5 4.5 1 6.5 2.3 8 11 17 165 3.6 0 3.8 3.5 05/10/2006 07:40:00 5 0.4 6.1 4.2 3.8 0.8 5.7 1.9 4.9 0.5 6.1 3.4 8 5 12 165 3.6 0 4 3.3 05/10/2006 07:50:00 4.9 0.7 6.8 2.6 3.6 0.8 5.7 1.9 4.8 0.7 6.5 3 4 8 10 165 4.1 0.1 4.5 3.8 05/10/2006 08:00:00 5.6 0.6 6.8 3 4.7 0.9 6.5 2.3 5.5 0.7 7.2 3.4 11 6 14 165 4.1 0.1 4.5 3.8 05/10/2006 08:10:00 4.6 0.6 6.1 3.4 3.7 1 5.7 1.9 4.6 0.6 6.1 3.4 10 8 15 165 4.3 0.3 5 3.5 05/10/2006 08:20:00 3.6 0.7 4.9 1.9 2.6 0.8 4.9 1.1 3.5 0.7 4.9 1.9 359 9 4 165 4.9 0.2 5.5 4.5 05/10/2006 08:30:00 3.4 0.9 5.7 1.9 2.8 0.9 5.7 1.1 3.4 0.8 5.3 1.9 6 9 16 165 5.6 0.4 6.2 4.5 05/10/2006 08:40:00 4.8 0.7 6.5 3 3.6 1 6.5 1.5 4.7 0.7 6.5 2.6 5 9 4 165 4.6 0.1 5 4.3 05/10/2006 08:50:00 4.9 0.6 6.5 3.4 3.5 1.1 6.1 1.9 4.9 0.5 6.1 3.4 6 8 16 165 4.1 0.1 4.5 3.5 05/10/2006 09:00:00 4.3 0.5 5.7 2.3 2.9 0.8 5.3 1.5 4.3 0.5 5.7 3 3 6 16 165 4.1 0.2 4.8 3.8 05/10/2006 09:10:00 4.4 0.8 6.1 2.3 3.5 0.9 5.3 1.5 4.3 0.9 6.5 2.3 4 10 6 165 4.9 0.2 5.5 4.3 05/10/2006 09:20:00 5 0.7 6.5 3 4 0.9 6.5 1.9 5 0.6 7.2 3.8 353 8 10 165 5.4 0.3 5.7 4.3 05/10/2006 09:30:00 5 0.9 8 3.4 4.2 1 6.8 1.5 5 0.9 8 3 350 11 355 165 4.6 0.1 5 4.5 05/10/2006 09:40:00 6.2 0.8 7.6 3.8 6.1 0.8 8 3.8 6.2 0.9 8 4.2 327 8 338 165 4.8 0.2 5.2 4.5 05/10/2006 09:50:00 6.1 1.2 8.8 3 5.8 1.4 9.1 2.3 6.1 1.2 9.1 3 343 14 347 165 4.4 0 4.8 4.3 05/10/2006 10:00:00 4.8 1 7.2 2.3 4.4 1.2 7.2 1.5 4.7 1 7.2 2.6 347 23 332 165 4.1 0.2 4.5 3.5 05/10/2006 10:10:00 4.6 0.7 6.5 3 3.8 0.9 6.1 1.5 4.5 0.6 6.5 3 10 7 5 165 3.8 0.1 4 3.3 05/10/2006 10:20:00 4.4 0.7 6.1 2.3 3.4 0.9 5.7 1.5 4.4 0.5 6.1 3 6 8 14 165 3.5 0.1 3.8 3 05/10/2006 10:30:00 4 0.5 5.3 2.6 3.4 0.8 4.9 1.5 3.9 0.5 4.9 2.3 348 20 320 165 3.3 0.1 3.5 2.8 05/10/2006 10:40:00 5.5 1 8.4 3.4 5.4 1.1 8.4 3.4 5.3 1 8.8 3.4 338 8 344 165 3.5 0.1 3.8 3 05/10/2006 10:50:00 6.7 0.8 8.8 4.9 6.6 0.8 9.1 4.6 6.4 0.8 8.4 4.9 336 8 340 165 3.4 0.1 3.5 3 05/10/2006 11:00:00 7.9 0.9 9.9 6.1 7.9 0.9 10.3 5.7 7.7 0.9 9.9 5.7 341 6 339 165 3.3 0 3.5 2.8 05/10/2006 11:10:00 8.9 0.9 11.8 6.1 8.7 1.2 11.5 5.3 8.9 1 11.8 5.3 343 7 349 165 3.6 0.1 3.8 3.3 05/10/2006 11:20:00 8.7 1.2 13.3 6.1 8 1.7 12.6 3.8 8.7 1.2 12.6 6.5 348 9 351 165 3.7 0.2 4 3 05/10/2006 11:30:00 9.7 1.2 13 6.8 8.8 1.5 13 5.7 9.8 1.3 13 5.7 343 11 360 165 3.6 0 3.8 3.5 05/10/2006 11:40:00 9.2 1.1 13.3 6.8 9.1 1.2 13 6.1 9.2 1.2 13 5.7 336 12 352 165 3.7 0 4 3.3 05/10/2006 11:50:00 8.8 1.5 14.1 6.1 8 1.1 10.7 4.6 8.7 1.6 14.5 5.3 346 11 1 165 3.8 0.2 4.3 3.3 05/10/2006 12:00:00 10.6 1.6 15.3 6.8 9.3 1.5 14.1 5.3 10.6 1.8 16.1 7.2 350 9 11 165 4.1 0.1 4.5 3.5 05/10/2006 12:10:00 11.1 1.5 14.9 6.8 9.9 1.7 13.7 6.1 10.8 1.5 14.9 6.5 350 10 354 165 4.4 0.4 5 3.5 05/10/2006 12:20:00 11 1.5 15.3 7.6 9.3 1.7 14.1 5.3 10.8 1.6 14.9 6.8 353 10 8 165 4.9 0 5 4.3 05/10/2006 12:30:00 10 1.6 14.5 6.1 8.3 1.8 14.1 4.9 10 1.7 15.6 5.7 355 10 12 165 4.6 0.2 5 4.3 05/10/2006 12:40:00 10.7 1.4 13.7 7.2 9.3 2 14.9 4.6 10.6 1.6 15.6 6.8 351 9 348 165 4.1 0.2 4.5 3.5 05/10/2006 12:50:00 10.1 1.7 15.6 6.5 8.8 1.7 14.1 4.9 10.1 1.9 14.5 6.5 351 8 14 165 4 0.2 4.5 3.3 05/10/2006 13:00:00 9.4 1.3 14.1 6.5 7.4 1.5 11.8 4.6 9.4 1.3 14.1 6.1 358 8 10 165 4.3 0 4.5 3.8 05/10/2006 13:10:00 9.4 1.3 13.7 6.5 8 1.4 13 5.3 9.4 1.4 13.7 6.1 355 10 10 165 4.1 0.1 4.5 3.8 05/10/2006 13:20:00 8.7 1.7 12.2 3.8 7.2 1.6 12.2 2.6 8.6 1.8 12.2 4.6 353 9 339 165 4.3 0.1 4.8 3.8 05/10/2006 13:30:00 8.2 1.5 12.2 4.9 7.5 1.7 12.2 4.2 7.8 1.5 12.6 4.6 352 12 351 165 4.8 0.1 5 4.5 05/10/2006 13:40:00 6.8 1 9.9 4.6 6.3 1 8.8 3.4 6.6 1 10.7 4.2 345 9 352 165 4.8 0 5 4.3 05/10/2006 13:50:00 7.8 1.1 10.3 4.6 7 1.6 10.7 3.8 7.8 1.1 11.1 4.6 352 9 349 165 4.6 0 4.8 4.5 05/10/2006 14:00:00 6 1 9.5 4.2 4.9 1.3 8.4 2.3 5.9 1 9.5 3 359 12 358 165 4.7 0.1 5 4.5 05/10/2006 14:10:00 5.4 1 8.4 3.4 4.3 1.2 8 1.9 5.3 1 8 3.4 7 10 9 165 4.8 0.1 5.2 4.3 05/10/2006 14:20:00 6.4 0.9 8.4 4.6 6.1 1 8.4 3.4 6.3 0.9 8.8 4.2 20 7 16 165 4.1 0.2 4.8 3.5 05/10/2006 14:30:00 6.4 0.7 8.4 4.6 5.9 0.9 8 3.4 6.3 0.8 8 4.2 17 8 5 165 3.5 0.2 3.8 3 05/10/2006 14:40:00 6.5 0.7 8.4 4.6 6.1 0.9 8 3.4 6.5 0.8 8.4 3.8 16 7 12 165 3.5 0.2 3.8 3 05/10/2006 14:50:00 7 0.7 9.1 4.6 6.5 0.9 8.8 3 6.9 0.8 9.5 4.6 17 6 16 165 3.6 0.1 3.8 3.3 05/10/2006 15:00:00 7.4 0.5 8.4 5.3 6.9 0.7 8.4 3.8 7.4 0.6 8.8 5.3 17 4 19 165 3.6 0.1 4.3 3.3 05/10/2006 15:10:00 7.2 0.5 8.4 5.7 6.8 0.7 8 3.8 7.1 0.6 8.8 5.7 18 5 22 165 3.7 0.1 4 3.3 05/10/2006 15:20:00 7.3 0.4 8.8 5.7 6.7 0.6 8 4.2 7.5 0.5 8.4 5.7 16 4 18 165 3.7 0.1 4 3.3 05/10/2006 15:30:00 6.8 0.7 9.1 4.9 6.1 1 8 3 6.8 0.8 8.8 4.6 17 7 12 165 3.9 0.2 4.3 3.5 05/10/2006 15:40:00 7.4 0.6 8.8 4.9 7.1 0.9 8.8 3.4 7.4 0.6 9.1 5.3 22 5 21 165 3.8 0.1 4.3 3.5 05/10/2006 15:50:00 7 0.7 8.4 4.2 6.8 0.9 8.4 4.2 7.1 0.7 8.4 4.9 23 5 29 165 3.5 0.2 3.8 3.3 05/10/2006 16:00:00 6.4 0.4 7.6 4.6 6.1 0.5 7.2 4.6 6.5 0.5 8 4.9 22 4 23 165 3.5 0.2 3.8 3.3 05/10/2006 16:10:00 5.7 0.4 6.5 4.6 5.3 0.5 6.5 3.8 5.8 0.6 6.8 3.8 18 4 20 165 3.5 0.2 3.8 3.3 05/10/2006 16:20:00 5 0.5 6.1 3.4 4.6 0.5 5.7 3 5.2 0.5 6.1 3.8 17 3 16 165 3.6 0.2 4 3.3 05/10/2006 16:30:00 4.7 0.3 5.7 3.8 4.3 0.5 5.3 2.6 5 0.4 5.7 3.8 18 4 20 165 3.8 0 4 3.3 05/10/2006 16:40:00 4.7 0.3 5.3 3.8 4.5 0.4 5.3 3 4.9 0.4 5.7 4.2 19 4 18 165 4.1 0.1 4.5 3.5 05/10/2006 16:50:00 4 0.4 4.9 3 3.4 0.7 4.9 1.5 4.3 0.4 5.3 3 15 6 11 165 4.4 0 4.5 4.3 05/10/2006 17:00:00 4.1 0.4 4.9 2.6 4 0.4 4.9 1.9 4.3 0.4 5.3 3 21 3 20 165 4.4 0 4.5 4.3 05/10/2006 17:10:00 4 0.4 4.9 2.6 4 0.4 4.6 2.6 4.1 0.5 4.9 3 24 4 24 165 4.4 0.1 4.8 4.3 05/10/2006 17:20:00 4 0.3 4.6 3 4 0.4 4.9 3 4.2 0.4 4.9 3 28 3 28 165 4.5 0 4.8 4 05/10/2006 17:30:00 3.6 0.5 4.6 2.3 3.6 0.5 4.6 2.3 3.8 0.5 4.6 2.6 27 5 33 165 4.6 0.1 4.8 4.3 05/10/2006 17:40:00 3.7 0.5 4.9 2.3 3.7 0.5 4.6 1.9 3.8 0.5 4.9 2.6 26 6 25 165 4.6 0 4.8 4.3 05/10/2006 17:50:00 3.8 0.5 4.9 2.6 3.7 0.5 4.9 1.9 4 0.4 4.9 3 23 6 20 165 4.3 0 4.8 3.8 05/10/2006 18:00:00 3.6 0.4 4.6 1.9 3.5 0.5 4.6 1.9 3.8 0.5 4.9 2.3 22 5 21 165 4.3 0 4.8 3.8 05/10/2006 18:10:00 3.6 0.3 4.2 3 3.6 0.3 4.2 2.6 3.9 0.3 4.6 3 25 4 21 165 4.6 0.1 4.8 4 05/10/2006 18:20:00 3.4 0.4 4.2 2.3 3.3 0.4 4.2 2.3 3.4 0.4 4.2 2.3 23 4 18 165 4.5 0 4.8 4.3 05/10/2006 18:30:00 3 0.3 3.8 2.3 2.8 0.5 3.8 0.7 3.2 0.3 4.2 2.3 17 5 18 165 4.5 0 4.8 4.3 05/10/2006 18:40:00 2.6 0.4 3.4 1.9 2.4 0.5 3.4 1.1 2.8 0.4 3.8 1.9 17 5 20 165 4.6 0 4.8 4.5 05/10/2006 18:50:00 2.4 0.5 3.4 1.1 2.3 0.6 3.8 0.7 2.6 0.5 3.8 1.5 20 8 25 165 4.4 0 4.8 4.3 05/10/2006 19:00:00 2.8 0.4 3.4 1.5 2.6 0.4 3.4 1.9 2.9 0.4 3.8 1.9 17 4 18 165 4.1 0.2 4.5 3.5 05/10/2006 19:10:00 3.6 0.4 4.6 2.3 3.6 0.5 4.6 2.3 3.6 0.5 4.6 1.9 20 3 22 165 4 0 4.3 3.8 05/10/2006 19:20:00 3.6 0.2 4.2 2.6 3.4 0.3 4.2 2.6 3.5 0.3 4.2 2.6 18 3 15 165 3.8 0 4 3.5 05/10/2006 19:30:00 4 0.4 4.9 2.6 3.7 0.6 4.9 2.3 3.9 0.4 4.9 2.6 17 4 22 165 3.6 0 3.8 3.3 05/10/2006 19:40:00 4.6 0.3 5.3 3.8 4.5 0.4 5.3 3 4.6 0.4 5.3 3.4 18 3 20 165 3.5 0.2 3.8 3 05/10/2006 19:50:00 4.9 0.2 5.7 4.2 4.6 0.4 5.7 3 5.1 0.2 5.7 4.6 15 2 19 165 3.5 0.2 3.5 3 05/10/2006 20:00:00 4.8 0.2 5.3 4.2 3.7 0.9 5.3 1.9 5 0.2 5.7 4.2 11 4 19 165 3.3 0 3.5 2.8 05/10/2006 20:10:00 4.8 0.3 5.7 4.2 3 0.7 4.9 1.5 5 0.3 5.7 4.6 7 4 11 165 3.3 0 3.5 2.8 05/10/2006 20:20:00 5.3 0.3 6.1 4.2 3.8 0.7 5.7 1.9 5.5 0.3 6.5 4.6 10 3 14 165 3.3 0 3.5 2.8 05/10/2006 20:30:00 4.9 0.4 6.1 4.2 3 0.8 6.1 1.5 5.1 0.4 6.5 3.8 8 3 15 165 3.3 0 3.5 2.8 05/10/2006 20:40:00 4.2 0.3 4.9 3.4 2.6 0.6 4.2 1.5 4.2 0.3 4.9 3.4 7 4 9 165 3.3 0 3.5 2.6 05/10/2006 20:50:00 4.3 0.6 5.7 2.6 3 0.8 5.3 0.7 4.2 0.8 5.7 2.3 6 9 8 165 3.3 0 3.5 2.8 05/10/2006 21:00:00 3.6 0.4 4.6 2.6 3.2 0.6 4.6 1.5 3.6 0.5 4.9 2.3 350 8 355 165 3.2 0 3.5 3 05/10/2006 21:10:00 2.9 0.6 4.2 1.5 2.1 0.6 3.8 0.4 2.7 0.8 3.8 1.1 8 8 9 165 3.2 0 3.5 3 05/10/2006 21:20:00 3.8 0.5 4.9 2.3 2.8 0.8 4.9 1.1 3.6 0.7 4.9 1.5 9 7 12 165 3.2 0 3.5 2.8 05/10/2006 21:30:00 3.4 0.6 4.6 1.9 2.5 0.9 4.2 0.7 3.2 0.8 4.6 1.1 3 10 351 165 3.3 0 3.5 2.8 05/10/2006 21:40:00 3.4 0.4 4.6 2.6 2.4 0.8 4.6 1.1 3.3 0.4 4.2 2.3 355 8 356 165 3.2 0 3.3 3 05/10/2006 21:50:00 4.2 0.5 5.3 2.6 2.9 0.8 4.9 1.1 3.9 0.6 5.3 2.3 360 9 1 165 3.2 0 3.3 3 05/10/2006 22:00:00 4.9 0.5 5.7 3.4 3.1 0.7 5.3 1.5 4.7 0.5 5.7 3 7 5 4 165 3.2 0 3.5 3 05/10/2006 22:10:00 4 0.4 4.9 3 2.2 0.6 4.2 0.7 3.9 0.4 4.9 2.6 4 5 356 165 3.1 0 3.3 3 05/10/2006 22:20:00 4.5 0.5 5.7 3.4 3.4 0.8 5.3 1.5 4.4 0.5 5.7 3.4 11 6 19 165 3.2 0 3.3 2.8 05/10/2006 22:30:00 4.6 0.7 6.5 3 3.4 1 6.1 1.5 4.4 0.6 6.1 2.6 9 8 17 165 3.2 0 3.3 3 05/10/2006 22:40:00 4.7 0.7 6.1 2.6 3.5 1 5.7 1.5 4.6 0.7 6.1 2.6 11 6 19 165 3.1 0 3.3 2.8 05/10/2006 22:50:00 3.9 0.7 5.7 2.3 2.7 0.9 5.3 1.1 3.6 0.6 5.3 2.3 358 9 351 165 3 0 3.3 2.8 05/10/2006 23:00:00 3.7 0.8 5.7 1.5 3.3 1 6.1 1.1 3.4 0.8 6.1 0.4 346 13 356 165 3 0 3.3 2.8 05/10/2006 23:10:00 3.3 0.6 5.3 1.9 2.5 0.6 4.2 1.1 3 0.6 4.6 1.5 355 9 4 165 3.1 0 3.3 2.8 05/10/2006 23:20:00 4.1 0.5 5.7 3 2.9 0.7 4.9 1.5 3.9 0.5 5.3 2.6 355 5 349 165 3 0 3.3 2.8 05/10/2006 23:30:00 4 0.5 5.7 2.6 3.9 0.6 5.3 2.3 3.7 0.5 5.3 2.3 344 7 337 165 3 0 3.3 2.8 05/10/2006 23:40:00 4.2 0.6 5.7 3 4 0.7 6.1 1.9 4 0.6 5.7 2.6 344 8 343 165 3 0 3.3 2.6 05/10/2006 23:50:00 5.5 0.6 7.2 4.2 5.2 0.9 7.2 3 5.2 0.6 7.2 3.8 347 5 351 165 3 0.1 3.3 2.3 05/11/2006 00:00:00 5.5 0.6 6.8 4.2 4.9 0.9 6.8 2.6 5.2 0.6 6.5 3.8 349 7 349 165 2.8 0 3 2.3 05/11/2006 00:10:00 5.3 0.6 6.8 3.8 4.6 1 6.8 1.9 5 0.6 6.1 3.4 352 9 351 165 3 0.1 3.3 2.6 05/11/2006 00:20:00 6.2 0.9 8 4.2 6 1.1 7.6 3.4 5.9 0.9 7.6 3.8 27 9 18 165 2.9 0.2 3.3 2.1 05/11/2006 00:30:00 6.5 0.5 8 5.3 6.3 0.6 8 4.6 6.6 0.6 8 4.9 22 4 25 165 2.3 0 2.6 2.1 05/11/2006 00:40:00 5.8 0.7 7.2 4.2 3.6 1.2 6.5 1.5 5.6 0.8 7.2 4.2 5 8 12 165 2.1 0 2.3 2.1 05/11/2006 00:50:00 5.2 0.5 6.1 4.2 3.8 0.8 5.7 2.3 5.2 0.4 6.5 4.2 355 6 358 165 2.3 0 2.3 1.8 05/11/2006 01:00:00 5.4 0.6 6.8 3.4 5.2 0.7 7.2 3.4 5.2 0.6 6.5 3.4 341 8 345 165 2.4 0 2.6 1.8 05/11/2006 01:10:00 4.6 0.6 5.7 2.6 3.6 1 6.1 1.5 4.5 0.7 6.1 2.3 357 10 349 165 2.4 0 2.6 2.3 05/11/2006 01:20:00 5.3 0.6 7.2 3.8 3.9 1 6.8 2.3 5.5 0.7 6.8 3.8 4 9 8 165 2.5 0 2.8 2.3 05/11/2006 01:30:00 3.9 0.6 5.7 2.3 3.9 0.7 5.7 2.3 3.9 0.7 5.7 2.6 339 8 319 165 2.5 0 2.6 2.3 05/11/2006 01:40:00 3.8 0.6 5.3 2.6 3.7 0.7 5.7 1.9 3.7 0.5 4.9 2.3 335 11 340 165 2.7 0 2.8 2.6 05/11/2006 01:50:00 3.7 0.6 5.7 1.9 3.7 0.6 5.3 1.9 3.6 0.6 5.3 2.3 335 10 349 165 2.7 0 2.8 2.6 05/11/2006 02:00:00 5.2 0.7 8 3 5.2 0.7 7.6 3 5 0.7 7.2 3.4 344 6 354 165 2.7 0 2.8 2.6 05/11/2006 02:10:00 5.6 0.5 6.8 4.2 5.5 0.6 7.2 3.8 5.4 0.5 6.5 3.8 342 6 348 165 2.9 0 3 2.8 05/11/2006 02:20:00 5.5 0.6 7.2 4.2 5.2 0.8 6.8 2.6 5.3 0.6 6.8 3.8 348 5 358 165 2.9 0 3 2.8 05/11/2006 02:30:00 6.2 0.6 8 4.9 4.7 1.1 8 2.6 6 0.6 8 4.2 356 6 353 165 2.9 0 3 2.8 05/11/2006 02:40:00 5.6 0.7 7.6 4.2 5.3 0.8 7.6 2.6 5.4 0.8 7.6 3.4 347 7 7 165 2.9 0 3.3 2.8 05/11/2006 02:50:00 5.1 0.7 6.5 3.4 5.1 0.7 6.8 3.4 4.8 0.6 6.5 3.4 341 6 344 165 2.9 0 3 2.8 05/11/2006 03:00:00 5.5 0.6 7.2 3.8 5.4 0.7 7.2 3.4 5.2 0.5 6.5 3.8 343 6 351 165 2.9 0 3 2.8 05/11/2006 03:10:00 5.6 0.6 7.2 3.8 5.7 0.6 7.6 4.2 5.5 0.5 6.8 4.2 342 4 348 165 2.8 0 2.8 2.6 05/11/2006 03:20:00 5.7 0.7 7.6 4.2 5.8 0.8 7.6 4.2 5.4 0.8 6.8 3.4 342 5 337 165 2.7 0 2.8 2.6 05/11/2006 03:30:00 7 0.8 9.5 4.9 7 0.9 9.1 4.2 6.9 0.8 8.8 4.9 342 8 357 165 2.9 0.1 3 2.6 05/11/2006 03:40:00 7 0.8 8.4 4.6 6.6 1.3 8.8 3.4 6.9 1 9.1 4.2 348 8 340 165 3 0.1 3.3 2.6 05/11/2006 03:50:00 6.1 0.9 8.4 3.8 6 1.1 8.8 3 5.7 1 8.4 3.4 343 8 328 165 3 0.1 3.3 2.6 05/11/2006 04:00:00 6.2 0.9 8.4 4.6 4.9 1.2 8 2.6 6.1 0.9 8.4 4.2 357 7 356 165 2.9 0 3 2.3 05/11/2006 04:10:00 5.4 0.6 7.6 3.8 4.4 1 7.6 2.3 5.4 0.8 8 3.4 355 12 16 165 2.7 0 2.8 2.6 05/11/2006 04:20:00 5.2 0.9 7.6 3 4.4 1 7.2 2.3 5 0.8 7.2 3 353 9 353 165 2.6 0 2.8 2.6 05/11/2006 04:30:00 5.2 1.1 7.6 2.3 4.5 1 6.1 2.3 5 1.3 8 2.6 348 11 358 165 2.6 0 2.8 1.8 05/11/2006 04:40:00 6 0.8 8.8 3.8 6 0.9 8.8 3.4 5.9 0.8 8.8 3.8 339 8 339 165 2.6 0 2.8 2.6 05/11/2006 04:50:00 7.4 0.8 9.1 4.9 7.3 1 9.5 4.6 7.2 1 9.9 4.6 342 8 344 165 2.7 0 3 2.3 05/11/2006 05:00:00 7.4 1.2 10.7 4.9 7.4 1.4 11.5 3.8 7.2 1.3 10.7 4.6 341 7 342 165 2.9 0 3.3 2.6 05/11/2006 05:10:00 7 0.7 9.5 5.7 6.3 1.2 9.5 3.4 6.7 0.9 9.5 4.6 350 6 353 165 2.8 0 2.8 2.3 05/11/2006 05:20:00 7.4 1.2 11.1 5.3 6.7 1.1 9.5 4.2 7.3 1.3 12.6 4.9 347 8 5 165 2.7 0 2.8 2.6 05/11/2006 05:30:00 6.4 0.6 8.4 4.6 6.3 0.6 8 4.2 6.2 0.6 7.6 4.2 344 6 358 165 2.5 0 2.8 2.3 05/11/2006 05:40:00 7.2 0.8 9.5 4.9 7.2 1 10.3 4.9 6.7 0.8 9.1 4.9 340 8 343 165 2.5 0 2.8 2.3 05/11/2006 05:50:00 7.4 0.8 9.9 5.3 7 1 9.1 3.8 7.2 0.9 9.5 5.3 349 6 356 165 2.5 0 2.8 2.6 05/11/2006 06:00:00 6.7 0.8 8.8 4.9 6.6 0.9 8.8 4.2 6.3 0.8 8.4 4.2 346 6 349 165 2.6 0 2.8 2.3 05/11/2006 06:10:00 8.1 1 11.5 6.1 6.6 1.3 10.7 4.2 8 1 11.5 5.7 353 8 358 165 2.7 0 2.8 2.6 05/11/2006 06:20:00 7.7 0.7 9.9 6.1 7.3 1.1 10.3 4.2 7.2 0.8 9.9 5.3 349 6 344 165 2.7 0 2.8 2.6 05/11/2006 06:30:00 8.3 1.1 11.1 5.3 6.8 1.2 10.3 4.2 7.9 1.2 11.1 4.9 354 8 360 165 2.7 0 2.8 2.3 05/11/2006 06:40:00 7.7 1.6 11.8 3.8 6.8 1.6 11.8 3 7.3 1.6 11.1 3.8 351 9 357 165 2.7 0 2.8 2.6 05/11/2006 06:50:00 9.3 1.4 12.6 6.5 7.9 1.7 12.6 4.2 9 1.5 12.6 5.7 352 8 359 165 2.9 0 3.3 2.6 05/11/2006 07:00:00 10.2 1.2 14.1 8 8.3 1.4 11.8 5.3 9.7 1.2 13.7 6.8 354 8 9 165 3 0 3.3 2.8 05/11/2006 07:10:00 8.9 1.1 12.6 6.1 7.9 1.1 10.7 4.6 8.4 1.2 13 5.3 350 10 360 165 3 0 3.3 2.8 05/11/2006 07:20:00 10 1.2 13 7.2 8.2 1.7 12.6 4.9 9.6 1.2 12.6 6.1 353 7 356 165 3.2 0 3.5 3 05/11/2006 07:30:00 8.9 1.2 12.6 5.3 7 1.5 11.8 4.2 8.8 1.2 12.2 4.9 357 8 358 165 3.3 0 3.5 3.3 05/11/2006 07:40:00 9.1 1 12.2 6.8 6.8 1.3 11.1 4.2 8.9 1 12.2 6.1 3 7 6 165 3.3 0 3.5 3.3 05/11/2006 07:50:00 9.2 1 11.8 6.5 7 1.5 11.5 3.8 9.1 1.2 12.2 6.1 3 9 11 165 3.5 0 3.5 3.3 05/11/2006 08:00:00 8.8 1 10.7 5.7 6.4 1.4 9.9 3.8 8.8 1.1 11.5 6.1 6 7 11 165 3.5 0 3.5 3 05/11/2006 08:10:00 8.2 1 10.3 6.1 6.4 1.5 9.9 3.8 8.2 1.1 10.7 5.7 5 9 358 165 3.3 0 3.5 3 05/11/2006 08:20:00 8.1 0.9 9.9 5.7 6.6 1.5 9.9 3 7.9 1 10.7 5.7 10 7 20 165 3.2 0 3.5 2.8 05/11/2006 08:30:00 8.1 1 11.1 5.7 6.1 1.2 10.7 3.4 8 1 11.1 5.7 2 8 2 165 3.3 0 3.5 3 05/11/2006 08:40:00 8 1.2 11.8 5.7 6.5 1.6 9.9 3.4 7.8 1.2 11.5 5.3 10 8 13 165 3.2 0.2 3.5 2.6 05/11/2006 08:50:00 8.2 0.8 9.9 5.7 6.7 1.2 9.1 3.4 8 1 10.3 4.9 11 6 2 165 3.1 0 3.5 2.3 05/11/2006 09:00:00 7.7 1 9.9 4.9 6 1.3 9.1 3 7.8 1 10.3 5.3 8 7 7 165 3.5 0.1 3.8 3 05/11/2006 09:10:00 7.4 0.8 9.5 5.3 5.7 1.3 9.5 3 7.3 0.8 9.5 5.3 360 8 4 165 3.9 0.2 4.3 3.3 05/11/2006 09:20:00 7.4 0.9 10.7 4.9 5.8 1.2 10.3 3.4 7.4 0.9 9.5 5.3 7 8 358 165 3.8 0.1 4.3 3.3 05/11/2006 09:30:00 7.7 1.1 11.5 5.3 5.8 1.6 10.7 3 7.6 1.1 10.3 5.3 4 9 347 165 4 0.2 4.5 3.3 05/11/2006 09:40:00 6.6 1 9.1 3.4 4.8 1.2 8.4 2.6 6.4 1 8.8 3.8 7 8 18 165 4.7 0.1 5 4.3 05/11/2006 09:50:00 7.2 0.7 9.1 4.6 5.4 1.1 8.8 3 7.2 0.7 9.1 5.7 5 9 356 165 4.6 0.1 5 4.3 05/11/2006 10:00:00 6.6 1.1 9.5 4.2 4.7 1.2 8.8 2.3 6.6 1.1 9.5 3.8 360 7 9 165 4.8 0 5 4.5 05/11/2006 10:10:00 5.7 1 8.4 3.4 4.7 1 7.6 2.3 5.6 1 8 3.4 6 9 15 165 4.6 0.2 5 4 05/11/2006 10:20:00 7.1 1 9.5 4.9 5.3 1.1 8.4 3.4 6.8 1.1 9.9 4.6 6 10 355 165 4.2 0.1 4.5 3.8 05/11/2006 10:30:00 6.5 0.7 8.8 4.2 5.1 1.1 8.8 2.6 6.4 0.7 8.4 4.2 1 10 355 165 5.1 0.4 5.7 3.8 05/11/2006 10:40:00 6.3 0.9 9.5 4.6 5.2 1.3 8.4 2.3 6.1 1 9.5 3.8 358 9 356 165 5.1 0.2 5.5 4.3 05/11/2006 10:50:00 7.1 1.1 9.5 4.9 6.5 1.5 9.9 3 7 1.1 9.9 4.2 11 15 25 165 3.8 0.4 4.8 3 05/11/2006 11:00:00 7.7 0.9 9.1 5.7 7.1 1.3 9.5 2.6 7.7 1 9.9 4.9 17 6 5 165 3.3 0 3.5 3 05/11/2006 11:10:00 6.6 0.6 8.4 5.3 5 1.1 7.6 2.3 6.7 0.6 8.4 4.9 7 7 359 165 4.2 0.5 5 3.3 05/11/2006 11:20:00 7.3 1 9.9 4.6 6.3 1.5 9.5 2.6 7.2 1 9.5 4.9 12 8 14 165 5.6 0.2 6 4.8 05/11/2006 11:30:00 7 0.8 9.9 4.2 6.3 1 8.8 3 6.9 0.9 9.5 4.6 14 8 8 165 5.8 0 6 5.5 05/11/2006 11:40:00 6.4 1.1 8.8 3.4 5.4 1.2 8.4 2.6 6.4 1.1 8.8 3.8 10 11 11 165 6.1 0 6.2 5.7 05/11/2006 11:50:00 6 0.8 7.6 4.2 5.2 1.1 7.6 2.6 5.9 0.8 8 3.8 11 11 27 165 6.6 0 7 6.2 05/11/2006 12:00:00 6.9 1 9.1 3.4 6.7 1 9.1 3 6.7 0.9 9.1 4.2 23 8 31 165 5.4 0.5 6.7 4.8 05/11/2006 12:10:00 7.7 0.9 9.9 5.3 7.6 0.9 9.5 5.3 7.6 0.9 9.5 4.9 25 6 22 165 4.2 0.3 5 3.3 05/11/2006 12:20:00 7 0.9 9.9 4.9 6.4 1.1 9.5 3.4 6.9 0.9 9.5 4.9 16 6 19 165 4.2 0.5 5 3.3 05/11/2006 12:30:00 6 0.9 8.8 3.8 5.8 1 8.4 3 6 0.9 8 3.8 20 9 22 165 4.8 0.5 5.5 3.5 05/11/2006 12:40:00 6.3 0.8 8.4 4.2 5.1 1 8 3 6.4 0.7 8 4.6 10 8 20 165 4.1 0.3 4.8 3.5 05/11/2006 12:50:00 7 0.8 9.1 4.6 6.1 1.3 8.8 2.6 6.9 0.9 9.1 4.9 11 9 11 165 5.2 0.3 5.7 4.5 05/11/2006 13:00:00 5.9 0.9 8 3.4 5.8 0.9 8 3.4 5.8 0.9 8 3.4 25 10 34 165 5.6 0.4 6.2 5 05/11/2006 13:10:00 6.4 1 8.4 3.4 6.2 1 8.4 2.6 6.3 1 8.4 3.8 20 7 16 165 5.1 0.1 5.5 4.5 05/11/2006 13:20:00 5.8 0.9 8 3 4.7 0.9 7.6 2.6 5.9 0.8 8.4 3.4 5 9 7 165 5 0 5.2 4.8 05/11/2006 13:30:00 5.5 0.8 7.2 2.6 5.2 0.9 7.2 2.6 5.5 0.9 7.2 3.4 16 7 18 165 5.3 0.2 5.7 4.5 05/11/2006 13:40:00 6.3 0.7 8 4.6 6 1 8 3.8 6.4 0.8 8 4.2 16 7 11 165 5.3 0.4 6.2 4.8 05/11/2006 13:50:00 5.6 0.8 7.6 3.4 5.4 0.9 7.2 3 5.7 0.9 7.6 3.8 18 8 31 165 6.2 0.1 6.5 6 05/11/2006 14:00:00 5.8 0.8 7.6 3.4 5.6 1 7.6 2.3 5.9 0.8 8 3.4 22 11 42 165 6.1 0 6.5 5.7 05/11/2006 14:10:00 6.1 1 8.4 3 6 1 8 3.4 6.1 0.8 9.1 3.8 26 8 13 165 5.9 0.1 6.2 5.5 05/11/2006 14:20:00 6.6 0.8 8.8 4.2 6.5 0.9 8.4 4.2 6.4 0.9 8.8 4.6 23 7 26 165 5.6 0.1 6.2 5.5 05/11/2006 14:30:00 5.7 0.8 8 3.4 5.6 0.9 7.6 2.6 5.8 0.8 7.6 3.4 25 9 23 165 6.2 0 6.7 6 05/11/2006 14:40:00 5.9 0.8 8 3.4 5.9 0.8 8 3.4 6 0.7 8.4 3.8 24 9 26 165 6.2 0 6.5 6 05/11/2006 14:50:00 6 0.8 8 3.8 5.6 0.8 7.6 3.4 6.2 0.8 8.4 4.2 19 9 17 165 6.2 0 6.7 6 05/11/2006 15:00:00 5.2 0.8 8 3 5.3 0.9 7.6 3.4 5.2 1 7.2 2.6 29 10 25 165 5.9 0.2 6.7 5.7 05/11/2006 15:10:00 5.8 0.7 7.6 4.2 5.9 0.7 7.6 4.2 5.7 0.7 7.2 3.8 28 8 36 165 5.3 0.2 6 4.8 05/11/2006 15:20:00 5.9 0.9 7.6 3.4 5.8 0.9 7.6 2.6 5.9 0.9 7.6 3.4 20 7 19 165 4.9 0.2 5.2 4.3 05/11/2006 15:30:00 6.1 0.7 8 3.8 5.9 0.8 8 3.4 6.2 0.8 8.4 4.2 18 9 19 165 5.7 0.4 6.2 4.8 05/11/2006 15:40:00 6.1 0.8 8.4 4.2 5.8 0.9 8 3.8 6.2 0.8 8.4 4.2 18 10 44 165 6.1 0.1 6.5 5.7 05/11/2006 15:50:00 6.3 1 9.1 4.2 5.6 1.2 8.8 3 6.3 1.1 8.8 3.4 11 9 17 165 6.2 0 6.5 6 05/11/2006 16:00:00 5.5 0.9 7.2 3 5.4 0.9 7.2 2.6 5.6 0.9 7.2 3 20 9 10 165 6.1 0.2 6.2 5.5 05/11/2006 16:10:00 7.1 1 9.5 4.6 6.4 1.4 9.1 3 7 0.9 8.8 4.2 13 13 13 165 5.4 0.2 6 5 05/11/2006 16:20:00 6.6 1 9.5 3.8 5.6 1.3 8.4 2.6 6.5 1 9.5 3.8 8 12 15 165 6.1 0.2 6.5 5.7 05/11/2006 16:30:00 6.6 1 8.4 3.8 6.5 1 8.8 3.8 6.5 1 8.8 4.2 24 9 33 165 5.5 0.3 6 4.8 05/11/2006 16:40:00 7.2 0.9 8.8 4.6 7.3 1 9.1 4.6 7.1 1 9.1 4.2 30 7 34 165 4.8 0.1 5 4.3 05/11/2006 16:50:00 6.6 0.9 9.1 4.6 5.9 1.3 8.8 2.6 6.6 0.9 9.1 4.6 15 10 18 165 4.6 0 4.8 4.3 05/11/2006 17:00:00 6.1 0.9 8 3.8 4.5 0.8 6.8 2.6 6.2 0.9 8 4.2 6 7 4 165 4.6 0 4.8 4.3 05/11/2006 17:10:00 6.1 0.7 8 4.2 4.4 0.9 7.2 2.6 6.2 0.6 8 4.6 0 7 360 165 4.3 0 4.8 3.8 05/11/2006 17:20:00 5.3 0.8 7.2 3.4 4.7 0.9 6.5 2.3 5 0.8 6.8 3 355 11 356 165 5.6 0.6 6.5 4.3 05/11/2006 17:30:00 5.7 0.8 7.6 3.8 4.7 1.1 7.2 2.3 5.7 0.8 7.6 3.8 7 9 13 165 6.7 0.1 7 6.2 05/11/2006 17:40:00 5.6 1.1 9.1 3.4 4.8 1.1 6.8 2.3 5.6 1.3 8.8 3 10 9 359 165 6.5 0 6.7 6.2 05/11/2006 17:50:00 4.7 0.8 6.8 2.3 4 1 6.1 1.9 4.7 0.7 6.5 2.6 9 10 5 165 6.7 0.1 7.3 6.2 05/11/2006 18:00:00 3.9 0.6 5.7 2.3 3.6 0.6 4.9 1.5 4.1 0.6 6.1 2.6 16 9 3 165 6 0.2 6.7 5.2 05/11/2006 18:10:00 4.2 0.6 5.7 2.3 3.5 0.7 5.3 1.9 4.2 0.5 5.7 3 5 11 8 165 5.7 0.1 6 5.5 05/11/2006 18:20:00 3.7 0.5 4.9 2.6 3.4 0.8 4.9 1.5 3.8 0.5 4.9 2.6 16 9 16 165 5.7 0 6 5.5 05/11/2006 18:30:00 4.2 0.6 5.7 2.3 3.5 0.7 5.7 1.9 4.3 0.6 6.5 3 8 8 7 165 5.4 0 5.7 5.2 05/11/2006 18:40:00 3.4 1 5.3 1.5 3.2 0.8 5.3 1.5 3.3 0.9 5.3 1.5 10 17 354 165 5.5 0 5.7 5.5 05/11/2006 18:50:00 4.7 0.5 6.1 3 3.8 0.8 5.7 1.9 4.5 0.6 6.1 3 359 10 10 165 5.8 0.1 6 5.5 05/11/2006 19:00:00 4.1 0.7 6.1 2.3 3.7 0.9 6.8 1.5 3.9 0.6 5.7 2.3 360 13 349 165 6.2 0.2 6.5 5.7 05/11/2006 19:10:00 4.5 1 6.8 2.3 3.6 1 6.1 1.5 4.3 1 6.5 2.3 7 10 8 165 6.2 0.1 6.2 5.7 05/11/2006 19:20:00 4.9 0.7 6.8 3.4 4 1.2 7.6 1.5 4.8 0.7 6.8 3 359 11 347 165 6.1 0 6.2 5.7 05/11/2006 19:30:00 4.7 0.7 6.5 3.4 3.5 1 6.1 1.5 4.8 0.7 6.8 3.4 4 8 349 165 6 0.2 6.5 5.5 05/11/2006 19:40:00 5.9 0.8 8 4.2 4.6 1.5 7.6 1.9 5.8 0.8 7.6 3.8 355 9 349 165 5.6 0.1 6 4.8 05/11/2006 19:50:00 4.9 0.7 7.2 3.4 5 0.8 7.2 3.4 4.7 0.8 7.6 3 342 6 349 165 5.7 0.2 6 5 05/11/2006 20:00:00 4.8 0.5 6.1 3 4.5 0.8 6.1 1.9 4.7 0.5 6.1 2.6 343 12 330 165 5.4 0.2 5.7 5 05/11/2006 20:10:00 5.7 0.9 8.8 4.2 5.6 1 8.8 3 5.4 1 8.4 3.4 341 8 342 165 5.1 0.2 5.7 4.5 05/11/2006 20:20:00 5.2 0.6 6.5 3.4 5 0.7 6.5 3 4.9 0.6 6.5 2.6 345 8 339 165 5.1 0.2 5.5 4.8 05/11/2006 20:30:00 5.4 0.8 7.2 3.8 5.1 1 7.6 2.3 5.2 0.8 6.8 3 348 6 350 165 5 0 5.7 4.5 05/11/2006 20:40:00 5.6 0.7 8.4 4.2 4.6 1 7.6 2.3 5.5 0.8 8 3.8 355 8 12 165 4.9 0 5 4.5 05/11/2006 20:50:00 5 0.6 6.5 3.8 4.4 0.8 6.5 2.3 4.9 0.6 6.8 3.8 348 9 354 165 4.4 0.2 4.8 4 05/11/2006 21:00:00 4.3 0.5 6.1 3 4.1 0.9 5.7 1.5 4.2 0.6 5.3 3 346 9 349 165 4.1 0 4.3 3.8 05/11/2006 21:10:00 4.4 0.7 6.1 3 4.3 0.9 6.5 1.5 4.4 0.6 6.5 3 344 8 347 165 4 0 4.3 3.8 05/11/2006 21:20:00 5.6 0.8 7.6 3.4 5 1.1 7.6 2.3 5.3 0.8 7.2 3 350 9 350 165 4 0 4.3 3.8 05/11/2006 21:30:00 4.8 0.6 6.1 3.4 4.1 1 6.5 1.9 4.7 0.7 6.5 3.4 351 6 1 165 3.9 0 4.3 3.8 05/11/2006 21:40:00 4.6 0.5 6.1 3.4 4.1 1 6.5 1.9 4.5 0.5 5.7 3.4 350 6 346 165 4 0 4.3 3.8 05/11/2006 21:50:00 4.6 0.4 5.7 3.8 4.5 0.6 5.7 2.3 4.5 0.4 5.7 3 345 7 343 165 3.8 0 4 3.5 05/11/2006 22:00:00 4.5 0.5 5.7 2.6 4.2 0.8 6.1 2.3 4.4 0.6 6.1 3 346 8 345 165 3.8 0 4.3 3.5 05/11/2006 22:10:00 3.4 0.6 5.7 2.3 3 0.9 5.7 1.1 3.5 0.4 4.9 2.6 350 8 353 165 4.1 0.1 4.3 3.5 05/11/2006 22:20:00 3.3 0.7 6.1 2.3 2.9 0.8 6.1 1.1 3.2 0.8 5.3 1.9 346 11 348 165 4.1 0.1 4.3 3.5 05/11/2006 22:30:00 1.8 0.7 3.4 0.4 1.6 0.8 3.8 0.4 1.5 0.7 3.4 0.4 337 10 348 165 4.1 0.1 4.3 3.5 05/11/2006 22:40:00 1.1 0.7 3 0.4 1 0.7 2.6 0.4 0.9 0.7 3 0.4 321 24 349 165 4.3 0.1 4.5 3.5 05/11/2006 22:50:00 1.3 0.7 3.8 0.4 1.1 0.7 3.8 0.4 1 0.7 2.6 0.4 345 32 350 165 4.6 0.1 5 4.3 05/11/2006 23:00:00 1.3 0.5 2.6 0.4 1.1 0.5 2.6 0.4 1.3 0.6 2.6 0.4 360 15 20 165 4.6 0.1 4.8 4 05/11/2006 23:10:00 0.7 0.4 1.5 0.4 0.6 0.4 1.9 0.4 0.5 0.3 1.5 0.4 347 14 318 165 4.8 0 5 4.3 05/11/2006 23:20:00 1 0.5 2.6 0.4 0.9 0.5 2.6 0.4 0.7 0.5 3 0.4 2 30 351 165 4.9 0 5.2 4.5 05/11/2006 23:30:00 0.7 0.4 2.3 0.4 0.8 0.5 2.3 0.4 0.7 0.5 2.3 0.4 73 22 62 165 5.2 0.1 5.5 4.8 05/11/2006 23:40:00 0.7 0.4 2.3 0.4 0.7 0.5 2.6 0.4 0.6 0.4 2.3 0.4 81 28 84 165 4.8 0.2 5.2 4.3 05/11/2006 23:50:00 0.6 0.3 1.5 0.4 0.4 0.2 1.1 0.4 0.4 0.2 1.5 0.4 87 28 109 165 4.6 0.1 4.8 4.3 05/12/2006 00:00:00 0.5 0.2 1.1 0.4 0.4 0.1 1.1 0.4 0.4 0.1 0.7 0.4 133 12 126 165 4.6 0.1 5 4.3 05/12/2006 00:10:00 0.4 0.1 0.7 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 154 13 163 165 4.8 0 5 4.5 05/12/2006 00:20:00 0.5 0.3 1.1 0.4 0.5 0.2 1.1 0.4 0.4 0 0.4 0.4 139 13 136 165 4.7 0 5 4.5 05/12/2006 00:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 131 0 165 165 4.6 0 4.8 4.5 05/12/2006 00:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 131 0 165 165 4.5 0 4.8 4.5 05/12/2006 00:50:00 0.4 0.3 1.9 0.4 0.4 0.2 1.5 0.4 0.4 0.1 1.1 0.4 153 43 258 165 4.5 0 4.8 4.5 05/12/2006 01:00:00 1 0.6 3 0.4 1 0.8 3 0.4 0.5 0.4 2.3 0.4 249 30 286 165 4.5 0 4.8 4.3 05/12/2006 01:10:00 4 0.9 6.1 2.3 4.1 0.8 6.5 2.3 3.4 1 6.1 0.4 283 9 281 165 4.3 0 4.5 4.3 05/12/2006 01:20:00 5.3 0.6 6.8 3.4 5.4 0.6 6.8 3.4 4.9 0.8 6.8 2.6 288 7 289 165 4.6 0.1 4.8 4.5 05/12/2006 01:30:00 5.4 0.6 7.2 3.8 5.5 0.6 7.2 3.8 4.4 0.8 6.8 2.6 298 8 288 165 4.8 0 5 4.5 05/12/2006 01:40:00 4.7 0.8 7.2 3 4.8 0.8 7.2 3 3.8 0.7 6.1 2.3 300 8 306 165 5 0 5.2 4.8 05/12/2006 01:50:00 4.2 0.6 6.5 3 4.3 0.6 6.1 3 3.5 0.7 5.3 1.9 299 8 304 165 5.1 0 5.2 5 05/12/2006 02:00:00 4.5 0.6 6.5 2.6 4.6 0.6 6.5 3 3.6 0.6 4.9 2.6 302 9 320 165 5.1 0 5.5 5 05/12/2006 02:10:00 4.7 0.8 6.8 2.6 4.7 0.8 6.5 2.6 3.8 0.7 6.1 1.9 304 8 309 165 5.2 0 5.5 5 05/12/2006 02:20:00 4.9 0.8 7.2 3 4.8 0.8 7.2 3 4.1 0.7 6.8 2.3 309 10 310 165 5.2 0.1 5.5 4.8 05/12/2006 02:30:00 5.1 0.7 6.8 3 5.1 0.7 6.8 3 4 0.6 6.1 2.6 306 7 304 165 5.1 0 5.2 4.8 05/12/2006 02:40:00 6.1 0.6 7.6 4.2 6.1 0.6 8 3.8 4.7 0.8 6.8 3 302 7 301 165 5.2 0 5.5 4.8 05/12/2006 02:50:00 5.8 0.7 8.4 4.2 5.9 0.7 8.4 4.2 4.6 0.7 6.5 2.6 302 7 293 165 5.3 0 5.5 5 05/12/2006 03:00:00 4.5 0.7 6.5 3 4.6 0.7 6.5 3 4 0.8 6.5 2.3 295 8 297 165 5.4 0 5.7 5 05/12/2006 03:10:00 2.8 1 4.9 0.4 3 1 5.3 0.7 2.8 1 5.3 0.7 299 15 281 165 5.3 0 5.5 5.2 05/12/2006 03:20:00 1.8 0.7 3.8 0.4 2 0.8 4.2 0.4 1.8 0.6 3.4 0.4 293 8 284 165 5.3 0.1 5.7 5 05/12/2006 03:30:00 0.5 0.3 2.3 0.4 0.5 0.3 2.3 0.4 0.5 0.3 1.9 0.4 338 26 310 165 5.2 0.1 5.5 4.8 05/12/2006 03:40:00 0.5 0.3 1.9 0.4 0.5 0.3 1.9 0.4 0.4 0.2 1.5 0.4 161 102 231 165 5.8 0.1 6 5.2 05/12/2006 03:50:00 1.2 1 3.4 0.4 1.3 1 3.8 0.4 1 0.8 3.4 0.4 254 26 277 165 5.7 0 6 5.5 05/12/2006 04:00:00 3.7 0.5 4.9 2.3 3.8 0.6 4.9 2.3 3.6 0.6 4.9 1.5 282 7 279 165 5.7 0 5.7 5.5 05/12/2006 04:10:00 4.1 0.5 5.3 2.6 4.2 0.5 5.3 3 4.1 0.5 5.3 2.3 282 6 280 165 5.6 0 5.7 5.5 05/12/2006 04:20:00 3.5 0.5 4.6 2.3 3.6 0.5 4.9 2.6 3.7 0.5 4.9 1.9 285 6 284 165 5.6 0 5.7 5.2 05/12/2006 04:30:00 3.8 0.5 4.9 2.3 3.9 0.5 4.9 2.3 4.1 0.5 5.3 2.6 282 6 282 165 5.6 0 5.7 5.5 05/12/2006 04:40:00 3.8 0.8 5.3 2.3 3.9 0.8 5.7 2.3 3.9 0.8 5.3 2.3 287 8 283 165 5.7 0 6 5.5 05/12/2006 04:50:00 1.9 1.1 4.2 0.4 2 1.1 4.6 0.4 2.4 0.9 4.6 0.4 286 22 286 165 5.9 0 6 5.5 05/12/2006 05:00:00 2.3 1 4.6 0.4 2.6 1.2 4.9 0.4 3 0.9 4.9 0.4 269 13 286 165 6.1 0 6.2 5.5 05/12/2006 05:10:00 3.1 0.6 4.9 1.5 3.4 0.7 4.9 1.5 3.5 0.6 4.9 1.9 275 10 282 165 6.1 0 6.2 5.7 05/12/2006 05:20:00 4.4 0.7 6.1 2.3 4.5 0.7 6.1 2.3 4.3 0.6 5.7 2.6 282 7 290 165 6.1 0 6.2 5.7 05/12/2006 05:30:00 4.7 0.7 6.1 3 4.9 0.7 6.5 3 4.5 0.7 6.1 2.3 282 6 287 165 6.1 0.1 6.2 5.7 05/12/2006 05:40:00 3.7 0.9 5.7 1.5 4 0.8 5.7 1.9 3.9 0.9 5.7 1.5 279 6 286 165 6.2 0.1 6.2 5.7 05/12/2006 05:50:00 3.2 0.8 5.3 1.5 3.3 0.8 5.7 1.5 3.1 0.9 5.7 1.1 285 10 270 165 6.3 0.1 6.7 5.7 05/12/2006 06:00:00 1.6 0.8 3.4 0.4 1.6 0.9 3.4 0.4 1.3 0.8 3.4 0.4 319 29 290 165 6.4 0 6.7 5.7 05/12/2006 06:10:00 1.8 0.7 3.8 0.4 2 0.8 3.8 0.4 2.1 0.8 3.4 0.4 270 18 282 165 6.4 0 6.7 6.2 05/12/2006 06:20:00 3.3 0.6 4.9 1.9 3.4 0.5 4.9 2.3 3.5 0.6 5.3 2.3 284 7 289 165 6.5 0 6.7 6.2 05/12/2006 06:30:00 3.7 1.2 6.1 1.1 3.9 1.3 6.5 1.1 3.9 1.1 6.5 1.5 282 10 277 165 6.7 0 7 6.2 05/12/2006 06:40:00 4.3 0.8 6.1 2.3 4.6 0.7 6.8 3 4.5 0.9 6.8 2.3 277 10 268 165 7.1 0.3 7.8 6.2 05/12/2006 06:50:00 4.6 1 6.5 1.5 4.9 1 7.2 2.3 4.8 1 6.8 2.3 276 6 274 165 7.7 0.1 8.3 7 05/12/2006 07:00:00 2.3 0.7 4.2 0.4 2.5 0.6 4.2 1.1 2.1 0.8 4.2 0.4 276 11 277 165 8.6 0.3 9 7.8 05/12/2006 07:10:00 1.6 0.6 3.8 0.4 2 0.8 3.8 0.4 1.6 0.8 3.8 0.4 261 13 282 165 9.2 0.1 9.6 9 05/12/2006 07:20:00 1.6 0.5 2.6 0.4 2 0.8 3.4 0.4 1.7 0.9 3.4 0.4 274 14 275 165 9.8 0.2 10.3 9.3 05/12/2006 07:30:00 1.6 0.5 3 0.4 2 0.5 3 0.7 1.8 0.5 3 0.4 269 9 276 165 9.6 0 9.8 9.3 05/12/2006 07:40:00 1.4 1.1 3.8 0.4 1.5 1.1 3.8 0.4 1.4 1.1 3.8 0.4 288 26 282 165 9.2 0.4 9.8 8.3 05/12/2006 07:50:00 2.5 0.8 4.6 0.4 2.5 0.8 4.9 0.4 2.7 0.6 4.2 1.1 293 16 282 165 8.1 0.1 8.5 8 05/12/2006 08:00:00 0.5 0.4 2.3 0.4 0.5 0.3 2.3 0.4 0.6 0.5 2.3 0.4 331 43 325 165 8.4 0.3 9 7.8 05/12/2006 08:10:00 0.5 0.3 1.5 0.4 0.5 0.3 1.9 0.4 0.8 0.5 2.6 0.4 186 39 209 165 9 0.4 9.6 8.5 05/12/2006 08:20:00 1 0.5 2.3 0.4 1 0.5 2.6 0.4 1.2 0.5 2.3 0.4 300 53 291 165 9.8 0 10.1 9.6 05/12/2006 08:30:00 0.8 0.5 2.3 0.4 0.7 0.4 2.3 0.4 0.7 0.5 2.3 0.4 12 53 347 165 10.7 0.4 11.7 10.1 05/12/2006 08:40:00 0.7 0.4 1.9 0.4 0.8 0.5 1.9 0.4 0.8 0.5 1.9 0.4 310 36 311 165 10.3 0.3 11.1 10.1 05/12/2006 08:50:00 0.9 0.6 3 0.4 1.2 0.7 3 0.4 1.3 0.7 2.6 0.4 239 61 314 165 10 0.2 10.6 9.6 05/12/2006 09:00:00 1 0.6 2.6 0.4 1.4 0.7 3 0.4 1.3 0.6 2.6 0.4 275 21 258 165 9.9 0 10.3 9.6 05/12/2006 09:10:00 0.9 0.6 2.6 0.4 1.2 0.7 3 0.4 1 0.6 2.6 0.4 277 47 234 165 10 0 10.3 9.8 05/12/2006 09:20:00 2.5 0.9 4.2 0.4 2.8 0.8 4.2 0.4 2.4 0.8 3.8 0.4 280 19 284 165 9.8 0.2 10.3 9.6 05/12/2006 09:30:00 2 0.6 3.8 0.4 2.3 0.5 3.8 1.1 2.2 0.5 3.4 1.1 282 10 295 165 10 0.2 10.6 9.6 05/12/2006 09:40:00 0.9 0.4 1.9 0.4 1.3 0.5 2.6 0.4 1.2 0.5 2.6 0.4 294 36 269 165 10.7 0.3 11.7 10.3 05/12/2006 09:50:00 1.5 0.7 3.8 0.4 1.6 0.8 3.8 0.4 1.6 0.8 4.9 0.4 337 79 121 165 11.7 0.2 12.2 10.9 05/12/2006 10:00:00 0.6 0.4 2.3 0.4 0.8 0.5 2.6 0.4 0.7 0.5 2.3 0.4 185 66 177 165 10.4 0.2 11.1 10.3 05/12/2006 10:10:00 1.7 0.8 3.8 0.4 1.7 0.7 3.4 0.4 1.5 0.8 3 0.4 302 47 355 165 11.1 0.1 11.7 10.9 05/12/2006 10:20:00 2.4 0.6 3.8 0.7 2.1 0.5 3.8 0.7 2.4 0.6 4.6 0.7 351 24 357 165 11.3 0.2 11.9 10.9 05/12/2006 10:30:00 1.6 0.8 3.8 0.4 1.6 0.7 3.8 0.4 1.5 0.8 3 0.4 11 28 36 165 11.3 0 11.7 11.1 05/12/2006 10:40:00 1 0.7 2.6 0.4 1.1 0.6 2.6 0.4 1.1 0.6 2.6 0.4 353 29 356 165 11.7 0.3 12.7 11.1 05/12/2006 10:50:00 2.2 0.8 3.8 0.4 3 1 4.6 0.4 2.8 1 4.6 0.4 269 28 278 165 11.3 0.4 11.9 10.9 05/12/2006 11:00:00 2.5 0.6 4.2 0.7 3.2 0.5 4.2 1.5 3.2 0.5 4.6 1.9 271 9 277 165 11.1 0.4 11.9 10.6 05/12/2006 11:10:00 3.9 0.8 5.3 1.5 4.1 0.7 5.3 2.3 3.5 0.6 5.7 2.3 294 13 308 165 11.2 0.6 12.2 10.1 05/12/2006 11:20:00 4.4 0.5 5.7 3 4.5 0.5 5.7 3 3.7 0.5 5.3 2.6 299 6 292 165 10.3 0.2 11.1 9.8 05/12/2006 11:30:00 4.1 0.6 5.7 2.6 4.3 0.6 6.1 3 3.7 0.6 5.3 2.3 290 7 290 165 10.9 0.2 11.4 10.6 05/12/2006 11:40:00 4 0.8 6.1 1.9 4.3 0.7 6.1 2.6 3.9 0.8 5.7 1.9 286 9 301 165 11.7 0.1 12.2 11.4 05/12/2006 11:50:00 3 0.8 5.7 1.1 3.8 0.6 5.7 2.3 3.6 0.6 5.3 1.5 277 16 298 165 11.4 0.3 11.9 10.9 05/12/2006 12:00:00 2.4 0.5 3.8 1.5 3.1 0.4 4.2 1.9 2.8 0.5 4.2 1.5 274 9 289 165 12.4 0.3 13 11.7 05/12/2006 12:10:00 2.9 0.6 5.3 1.1 3.3 0.5 4.9 1.5 2.8 0.8 4.6 0.7 283 9 294 165 12.9 0.3 13.5 12.2 05/12/2006 12:20:00 3.1 0.9 5.3 0.7 3.5 0.8 5.3 1.5 2.9 1 5.3 1.1 286 12 276 165 13.1 0.1 13.5 12.5 05/12/2006 12:30:00 3.8 0.6 5.3 1.9 4.1 0.6 5.7 2.3 3.7 0.8 5.7 1.5 284 7 279 165 12.9 0.2 13.3 12.5 05/12/2006 12:40:00 4.3 0.7 6.1 2.6 4.5 0.6 6.8 2.6 3.8 0.8 6.1 1.9 292 9 287 165 12.3 0.2 12.7 11.9 05/12/2006 12:50:00 3.6 0.5 5.3 2.3 3.8 0.5 5.3 2.3 3.2 0.6 4.9 1.5 299 11 340 165 12.4 0.5 13.3 11.9 05/12/2006 13:00:00 2.3 0.6 4.2 0.7 2.9 0.5 4.2 1.5 2.6 0.6 4.2 0.7 274 14 290 165 13.6 0.2 14.1 12.7 05/12/2006 13:10:00 2.7 1 4.9 0.4 3.1 0.9 5.3 0.4 2.5 0.9 4.6 0.4 279 21 292 165 13.3 0.2 13.8 12.7 05/12/2006 13:20:00 3.3 0.8 5.7 1.1 3.5 0.8 5.7 1.1 2.8 0.7 4.6 1.1 290 16 297 165 14 0.2 14.4 13.3 05/12/2006 13:30:00 1.8 1.1 5.7 0.4 2.2 1.3 5.7 0.4 1.8 1 5.3 0.4 264 61 274 165 13.3 0.5 14.4 12.7 05/12/2006 13:40:00 3.1 0.9 5.3 0.7 3.4 0.9 5.7 1.1 2.3 0.8 4.6 0.4 287 29 297 165 12.9 0.1 13.3 12.5 05/12/2006 13:50:00 2.6 1 5.3 0.4 2.8 1 6.1 0.4 1.9 0.8 4.2 0.4 303 26 320 165 13.3 0 13.8 13 05/12/2006 14:00:00 2.8 0.8 4.6 0.4 3 0.7 5.3 1.1 2.4 0.7 4.2 0.4 315 38 305 165 13.1 0.2 13.5 12.5 05/12/2006 14:10:00 2.7 1.7 6.5 0.4 2.9 1.7 6.1 0.4 2.2 1.3 4.9 0.4 272 43 290 165 11.6 0.4 12.7 10.9 05/12/2006 14:20:00 2 1 3.8 0.4 2.2 0.9 3.8 0.4 2.4 0.8 4.6 0.4 166 35 153 165 10.3 0.4 11.4 9.6 05/12/2006 14:30:00 2.9 0.8 5.3 0.7 3.1 0.7 4.9 1.1 3.2 0.7 4.9 1.9 156 18 182 165 10.5 0.3 11.4 9.8 05/12/2006 14:40:00 2.5 1 4.9 0.4 2.7 1 4.9 0.4 2.8 1 4.9 0.4 149 17 162 165 10.8 0.4 11.7 9.8 05/12/2006 14:50:00 2.7 0.8 4.6 0.4 2.8 0.8 4.9 0.7 2.9 0.7 4.9 1.1 155 17 127 165 11.7 0.1 12.2 11.1 05/12/2006 15:00:00 2 0.9 4.2 0.4 2.3 0.8 4.6 0.4 2.6 0.8 4.9 0.7 158 22 165 165 11.2 0.2 11.7 10.6 05/12/2006 15:10:00 1.7 0.9 3.8 0.4 2 0.9 4.2 0.4 2.1 0.7 3.8 0.4 165 22 159 165 11.2 0.1 11.7 10.9 05/12/2006 15:20:00 2.4 1.6 5.7 0.4 2.7 1.5 5.7 0.4 1.9 1.1 5.3 0.4 265 56 274 165 12.1 0.6 13 10.9 05/12/2006 15:30:00 2.1 1.5 5.7 0.4 2.4 1.4 5.7 0.4 1.7 1.1 4.6 0.4 314 107 289 165 12.8 0.1 13.3 12.5 05/12/2006 15:40:00 4 1.4 6.5 0.4 4.3 1.4 6.5 0.4 2.8 1.3 6.1 0.4 289 41 302 165 13.1 0.1 13.3 12.7 05/12/2006 15:50:00 4.7 0.9 6.8 2.6 4.8 0.9 6.8 2.3 3.5 0.9 5.7 1.5 305 16 296 165 13.7 0.3 14.4 13 05/12/2006 16:00:00 4.8 0.9 7.2 2.6 4.9 0.9 7.2 2.3 4 1.1 6.5 0.7 314 16 282 165 14 0.1 14.6 13.8 05/12/2006 16:10:00 6.2 0.9 8.4 3.8 6.3 1 9.1 4.2 5.6 1.1 9.1 2.6 317 18 351 165 13.9 0.3 14.6 13.3 05/12/2006 16:20:00 6.3 1.1 8.4 3.4 6.3 1.1 8.8 3.4 5.8 1.1 8 3 322 17 316 165 13.6 0.3 14.1 12.7 05/12/2006 16:30:00 7.6 0.6 9.9 6.1 7.6 0.6 9.5 6.1 7.1 0.7 8.8 4.9 316 7 307 165 12.7 0 13 12.5 05/12/2006 16:40:00 7.7 0.8 10.3 4.6 7.7 0.8 9.5 5.3 7 0.8 9.5 4.2 313 8 307 165 12.5 0.1 13 12.5 05/12/2006 16:50:00 6.7 1 8.8 3.4 6.7 1 8.4 3.4 6 1 8 3 316 13 309 165 12.7 0.1 13 12.5 05/12/2006 17:00:00 5.9 0.7 8 3.4 6 0.7 8 3.8 5.1 0.9 7.2 3 315 12 310 165 13.5 0.1 13.8 13 05/12/2006 17:10:00 5.7 0.8 7.6 3.4 5.8 0.8 7.2 3 5.1 0.9 7.2 2.6 317 10 314 165 13.2 0 13.8 13 05/12/2006 17:20:00 5.3 0.8 6.8 3 5.4 0.8 7.6 2.6 5.1 0.8 6.8 3 326 11 305 165 13.4 0 13.5 13.3 05/12/2006 17:30:00 6.3 1.2 9.5 3 6.4 1.2 9.5 3 5.4 1.3 9.1 1.5 311 13 314 165 13.1 0.5 13.8 12.2 05/12/2006 17:40:00 7 0.8 9.5 4.6 7 0.8 9.5 4.2 6.5 0.8 8.4 4.6 317 9 310 165 12.1 0.2 12.7 11.7 05/12/2006 17:50:00 5.6 1.2 9.1 1.9 5.7 1.1 8.8 2.3 5 1.3 8.8 1.9 324 13 325 165 12.7 0.2 13.5 12.5 05/12/2006 18:00:00 5.8 1.2 8.8 2.6 5.9 1.2 9.1 3 5.1 1 8 2.3 313 10 307 165 12.6 0.3 13.3 11.9 05/12/2006 18:10:00 5.8 0.9 8.4 3.8 6 0.8 8.8 3.8 5.1 1 7.6 2.6 315 14 304 165 12.1 0 12.7 11.9 05/12/2006 18:20:00 4.7 1 7.2 2.6 4.9 1 7.2 2.6 4.3 0.8 6.1 2.3 323 17 302 165 12.5 0.3 13.3 11.9 05/12/2006 18:30:00 6 0.9 9.1 4.2 6.1 0.9 8.8 3.8 5.3 0.7 7.6 3.8 314 11 310 165 12.1 0.3 13 11.7 05/12/2006 18:40:00 5.4 1.1 8 2.6 5.5 1.1 7.6 2.6 4.5 1.1 7.2 1.9 315 12 306 165 11.8 0.1 12.2 11.7 05/12/2006 18:50:00 5.7 0.8 8 3.8 5.8 0.8 8.4 3.4 5.2 0.9 6.8 2.6 328 13 313 165 11.6 0 11.9 11.4 05/12/2006 19:00:00 5.5 1.1 8 2.6 5.7 1.1 8 3 4.9 1.2 7.6 1.9 315 12 321 165 11.7 0 11.9 11.4 05/12/2006 19:10:00 6.1 0.9 8 3.8 6.2 0.8 8 4.2 5.6 0.9 7.6 3.4 316 8 319 165 11.3 0.1 12.2 11.1 05/12/2006 19:20:00 7.2 1 10.3 3.8 7.2 1 9.9 4.2 6.4 1 8.8 3.8 314 6 313 165 10.9 0 11.4 10.9 05/12/2006 19:30:00 7 0.7 8.8 5.3 6.9 0.6 8.8 4.9 6.5 0.8 8.4 4.2 318 7 316 165 10.7 0 10.9 10.9 05/12/2006 19:40:00 7 0.7 8.8 4.9 7 0.7 8.8 5.3 6.5 0.7 8.4 3.8 319 7 324 165 10.7 0 10.9 10.3 05/12/2006 19:50:00 6.7 0.6 8.4 5.3 6.8 0.7 8 5.3 5.9 0.8 7.6 4.2 315 6 314 165 10.3 0.1 10.9 10.3 05/12/2006 20:00:00 5.3 0.7 7.6 3 5.5 0.7 8 3.4 4.5 0.7 6.5 3 317 8 307 165 10.3 0 10.6 10.1 05/12/2006 20:10:00 6.1 0.8 9.1 4.2 6.2 0.8 8.8 4.6 5.3 1.1 7.6 2.6 318 11 311 165 10.1 0 10.3 10.1 05/12/2006 20:20:00 6.2 0.9 8.8 4.2 6.4 0.9 8.8 4.2 5.5 0.8 8 3.4 313 7 310 165 9.8 0.2 10.3 9.6 05/12/2006 20:30:00 6.6 1 10.3 4.6 6.7 1 10.3 4.6 5.6 1.2 9.1 2.6 310 9 325 165 9.6 0 9.8 9 05/12/2006 20:40:00 7.7 1 10.3 4.6 7.8 1 10.3 4.9 6.6 1.1 10.3 2.3 310 9 314 165 9.4 0 9.6 9.3 05/12/2006 20:50:00 8.2 0.8 10.3 6.5 8.2 0.7 10.3 6.5 7.1 0.9 9.9 4.2 310 6 305 165 9 0.1 9.6 8.8 05/12/2006 21:00:00 8.8 0.9 11.5 6.5 8.7 0.8 11.5 6.5 7.6 1.1 11.5 4.9 312 7 305 165 8.7 0.1 9 8.3 05/12/2006 21:10:00 9.2 1 11.5 6.1 9.1 1 11.5 6.1 8.4 1.1 11.1 3.8 314 8 307 165 8.8 0.1 9.3 8.5 05/12/2006 21:20:00 8.2 1.1 12.2 4.9 8.2 1.1 12.2 5.3 7 1.2 10.7 4.2 312 8 313 165 8.7 0.2 9.3 8.3 05/12/2006 21:30:00 8.3 1.2 11.1 4.2 8.2 1.2 11.1 4.2 7.2 1.1 9.5 4.2 313 9 302 165 8.3 0.1 8.5 7.8 05/12/2006 21:40:00 8.5 0.8 11.1 6.8 8.5 0.7 10.7 6.8 7.3 0.9 9.9 4.9 311 7 314 165 8.3 0.1 8.5 8 05/12/2006 21:50:00 8.3 1 11.5 6.1 8.3 1 11.1 5.7 7.3 1 9.9 4.2 312 6 315 165 8.5 0.2 8.8 8 05/12/2006 22:00:00 7.9 0.9 10.3 5.7 7.8 0.9 9.9 5.7 7.1 0.9 9.5 4.2 320 7 320 165 8.4 0 8.5 8.3 05/12/2006 22:10:00 9.1 0.9 11.5 6.5 9.1 0.9 11.1 6.8 7.7 1.1 10.7 4.6 312 8 304 165 8.7 0 9 8.3 05/12/2006 22:20:00 9 1 11.5 6.5 9 1 11.8 6.5 7.5 1.1 10.3 4.2 308 7 309 165 8.9 0 9 8.5 05/12/2006 22:30:00 9.3 0.9 12.2 6.5 9.2 0.9 11.8 6.5 7.8 0.9 10.3 5.3 306 6 307 165 8.7 0 9 8.5 05/12/2006 22:40:00 8.8 1 12.2 6.1 8.7 1 11.8 6.1 7.4 1.2 12.6 4.6 309 8 310 165 8.6 0 8.8 8.5 05/12/2006 22:50:00 8.1 1.2 11.1 4.9 8 1.2 10.7 5.3 7.4 1.3 10.3 4.2 320 10 305 165 8.3 0 8.5 8 05/12/2006 23:00:00 8.3 1 10.7 4.9 8.3 1 10.7 5.3 7.4 1 9.9 4.6 317 10 301 165 8.5 0 8.8 8.3 05/12/2006 23:10:00 8.7 1 11.5 4.9 8.5 1 11.1 5.3 8.1 1 10.3 5.3 322 8 328 165 8.6 0.1 9 8 05/12/2006 23:20:00 8.5 0.9 11.5 4.9 8.4 0.9 11.1 4.9 8.2 1 11.5 4.9 322 10 336 165 8.8 0 9 8.5 05/12/2006 23:30:00 8.6 1 12.2 5.7 8.5 1 11.5 5.3 8.3 0.9 11.1 5.7 325 9 322 165 8.7 0 9 8.5 05/12/2006 23:40:00 9.1 1 11.1 6.5 9 1 11.1 6.5 8.9 1 11.5 6.8 326 9 322 165 8.8 0 9 8.5 05/12/2006 23:50:00 10.9 1.6 14.5 6.5 10.7 1.7 14.1 6.5 10.6 1.7 14.5 6.1 333 10 328 165 9.2 0.1 9.6 8.5 05/13/2006 00:00:00 10.6 1.2 14.1 6.5 10.5 1.3 14.5 6.5 10.3 1.5 15.3 6.5 338 10 336 165 9.2 0.1 9.6 9 05/13/2006 00:10:00 10.4 1 13.3 8.4 10.2 1.3 13 5.3 10.2 1.1 13.3 7.2 338 9 352 165 9 0 9.3 8.8 05/13/2006 00:20:00 9 1.2 12.6 6.5 8.7 1.4 12.2 5.3 8.8 1.2 12.2 6.1 339 13 332 165 8.9 0 9 8.5 05/13/2006 00:30:00 7.6 1 10.7 5.7 6.8 1.9 10.3 3 7.2 0.9 9.5 5.3 348 12 338 165 8.3 0.2 9 7.8 05/13/2006 00:40:00 7.8 0.7 9.9 5.7 6.8 1.4 10.3 3.8 7.4 0.8 9.9 5.3 350 10 340 165 7.9 0 8 7.5 05/13/2006 00:50:00 7.2 1.5 10.7 2.6 7 1.6 10.7 2.6 6.1 1.6 9.5 1.9 342 11 349 165 7.6 0 7.8 7.3 05/13/2006 01:00:00 3.8 1.2 6.5 0.4 3.5 1.1 6.5 0.4 2.6 1.1 5.3 0.4 354 20 360 165 7.4 0.1 7.8 6.7 05/13/2006 01:10:00 3.8 0.8 5.3 1.5 3.4 0.9 5.3 1.1 3.2 0.7 4.9 1.5 353 11 358 165 7 0.2 7.3 6.7 05/13/2006 01:20:00 4.6 1 7.6 1.9 4.4 1.3 7.2 1.9 4.2 1 7.2 1.5 346 11 331 165 6.7 0.1 7 6.2 05/13/2006 01:30:00 3.4 1 6.5 0.7 3 0.8 6.5 0.7 2.3 1.2 5.3 0.4 3 13 357 165 6.7 0 7 6.5 05/13/2006 01:40:00 3.4 0.8 5.3 1.5 2.9 0.8 5.7 1.5 2.9 1 4.9 0.4 4 13 349 165 6.6 0 6.7 6.2 05/13/2006 01:50:00 2.5 0.6 3.4 0.4 2 0.7 3.8 0.4 2.1 0.5 3.4 0.7 2 11 19 165 6.3 0.2 6.7 5.7 05/13/2006 02:00:00 2.2 0.5 3.8 1.1 2.2 0.6 3.8 0.7 1.7 0.7 3.4 0.4 335 23 338 165 6.2 0.2 6.2 5.5 05/13/2006 02:10:00 1.6 0.6 3.4 0.4 1.7 0.6 3.8 0.4 0.9 0.6 3.4 0.4 325 28 310 165 6.3 0.1 6.7 5.7 05/13/2006 02:20:00 1.1 0.7 3.4 0.4 1.3 0.7 3.4 0.4 0.5 0.4 2.6 0.4 323 24 322 165 6.8 0.1 7.3 6.2 05/13/2006 02:30:00 0.6 0.3 1.5 0.4 0.7 0.5 1.9 0.4 0.4 0.1 1.5 0.4 252 28 297 165 7.1 0 7.5 6.7 05/13/2006 02:40:00 1.2 0.5 2.3 0.4 1.5 0.5 2.6 0.4 0.9 0.5 2.3 0.4 176 32 165 165 7.4 0.1 7.8 7 05/13/2006 02:50:00 1.5 0.4 2.3 0.4 1.7 0.4 2.3 0.7 1.1 0.5 1.9 0.4 162 3 160 165 7.1 0.1 7.5 7 05/13/2006 03:00:00 1 0.4 1.9 0.4 1.4 0.3 2.3 0.7 0.6 0.4 1.9 0.4 116 15 165 165 7.2 0 7.3 6.7 05/13/2006 03:10:00 1.4 1 3 0.4 1.6 1 3.4 0.4 1.3 1 3 0.4 131 13 122 165 7.4 0 7.5 7 05/13/2006 03:20:00 2.1 0.3 2.6 1.1 2.5 0.3 3 1.5 2 0.3 2.6 0.7 112 5 116 165 7.1 0.1 7.5 6.7 05/13/2006 03:30:00 2.1 0.6 3.8 0.4 2.4 0.6 3.8 0.4 2.5 0.6 4.2 0.7 49 29 36 165 7.1 0 7.5 7 05/13/2006 03:40:00 2 0.7 4.2 0.4 2 0.7 3.8 0.4 2.4 0.6 4.6 1.1 18 13 9 165 7.1 0 7.5 7 05/13/2006 03:50:00 2.4 0.6 4.6 1.1 1.9 0.8 4.6 0.7 2.4 0.5 3.4 0.7 357 13 323 165 6.7 0 7.3 6.5 05/13/2006 04:00:00 2.8 0.7 4.9 1.1 2.9 0.8 4.9 1.1 2.8 0.6 4.6 1.1 331 23 286 165 6.6 0.2 7 6.2 05/13/2006 04:10:00 3.4 1.1 5.7 0.7 3.4 1.1 6.1 1.1 3.4 1 6.1 1.1 339 11 346 165 6.6 0.1 7 6.2 05/13/2006 04:20:00 3.4 1.1 6.1 1.1 3.4 1.2 6.5 1.1 3.5 1.2 6.5 1.5 341 9 338 165 6.7 0 7 6.5 05/13/2006 04:30:00 2.5 0.7 4.6 1.1 2.6 0.6 4.2 1.1 2.2 0.6 4.6 0.4 332 10 3 165 6.4 0.1 7 6 05/13/2006 04:40:00 0.6 0.4 3 0.4 0.7 0.5 2.6 0.4 0.5 0.3 1.5 0.4 317 26 261 165 6.6 0 7 6.2 05/13/2006 04:50:00 2.4 1 4.9 0.4 2.6 1 4.9 0.4 2 1.2 4.9 0.4 321 19 310 165 6.9 0.3 7.5 6.2 05/13/2006 05:00:00 2.9 1 5.3 0.7 2.8 0.9 5.7 0.7 2.6 1 4.9 0.4 337 15 358 165 6.9 0.1 7.3 6.7 05/13/2006 05:10:00 3.6 0.7 5.3 1.9 3.6 0.7 5.7 1.5 3.3 0.7 4.9 0.7 334 13 355 165 6.7 0.2 7 6.2 05/13/2006 05:20:00 3 0.7 4.2 0.7 3.2 0.7 4.6 0.7 2.6 0.8 4.2 0.7 299 15 290 165 6.6 0.1 7.3 6.2 05/13/2006 05:30:00 1.8 0.9 3.8 0.4 2.1 1 4.6 0.4 1.3 0.9 4.2 0.4 302 27 334 165 7.2 0.1 7.5 6.7 05/13/2006 05:40:00 3.1 0.8 5.3 1.5 3.4 0.8 5.7 1.5 2.8 0.9 5.7 1.1 285 11 275 165 6.8 0.1 7.3 6.2 05/13/2006 05:50:00 3.6 0.8 5.3 1.5 3.8 0.7 5.3 1.9 3.3 0.8 5.7 1.1 290 11 290 165 7 0.1 7.5 6.2 05/13/2006 06:00:00 2.9 0.5 4.2 1.1 3.2 0.4 4.2 1.9 2.6 0.7 4.6 0.7 290 14 302 165 7.4 0.4 8 6.7 05/13/2006 06:10:00 3 0.5 3.8 1.1 3.2 0.4 4.2 1.9 3.3 0.5 4.2 1.5 284 8 279 165 7.8 0.1 8.5 7.5 05/13/2006 06:20:00 3 0.7 4.6 1.1 3.2 0.7 4.6 0.7 2.6 0.6 4.2 0.7 288 11 292 165 8.1 0.1 8.5 7.8 05/13/2006 06:30:00 3.2 0.8 4.9 0.7 3.3 0.8 4.9 1.1 2.8 1 4.9 0.4 317 12 335 165 8.4 0.2 8.8 7.8 05/13/2006 06:40:00 2.6 0.9 4.6 0.7 2.7 0.8 4.6 1.1 2.5 1 4.2 0.4 319 12 319 165 8.9 0.2 9.3 8.3 05/13/2006 06:50:00 3 0.6 4.2 1.9 3.1 0.6 4.2 1.5 2.7 0.6 4.2 1.5 306 22 282 165 9.2 0.4 9.6 8.5 05/13/2006 07:00:00 3.3 0.5 4.6 1.9 3.4 0.5 4.6 2.3 3.4 0.5 4.6 1.9 290 7 289 165 8.4 0 8.8 8.3 05/13/2006 07:10:00 3.6 1 5.7 1.9 3.8 1 5.7 1.9 3.4 0.7 5.7 1.9 296 9 285 165 8.5 0.1 8.8 8 05/13/2006 07:20:00 4.8 0.5 6.1 3.4 4.9 0.5 6.1 3.8 4 0.6 6.5 3 301 7 295 165 8.5 0.1 8.8 7.8 05/13/2006 07:30:00 3.7 0.5 4.6 2.3 3.9 0.4 4.9 2.6 3.3 0.5 5.3 2.3 301 8 294 165 8.8 0 9 8.3 05/13/2006 07:40:00 2 0.8 3.8 0.4 2.4 0.7 3.8 1.1 1.9 0.6 3.4 0.4 297 15 314 165 9.6 0.6 10.6 8.8 05/13/2006 07:50:00 0.7 0.5 2.3 0.4 1 0.5 2.3 0.4 1 0.6 3 0.4 286 82 111 165 10.6 0 10.9 10.3 05/13/2006 08:00:00 1 0.6 2.6 0.4 1.1 0.6 3 0.4 0.9 0.5 2.3 0.4 0 76 37 165 10.9 0 11.4 10.6 05/13/2006 08:10:00 1.6 0.6 3 0.4 1.9 0.6 3 0.7 1.8 0.6 3 0.4 18 19 37 165 11.1 0 11.7 10.9 05/13/2006 08:20:00 1.1 0.5 2.6 0.4 1.5 0.5 2.6 0.4 1.5 0.5 3 0.4 62 22 92 165 10.6 0 10.9 10.3 05/13/2006 08:30:00 1.3 0.7 3.8 0.4 1.6 0.6 3 0.4 1.5 0.6 3 0.4 102 36 116 165 10.9 0.2 11.4 10.3 05/13/2006 08:40:00 0.5 0.5 2.6 0.4 0.6 0.5 2.6 0.4 0.7 0.5 3 0.4 20 90 175 165 11.4 0 12.2 11.1 05/13/2006 08:50:00 0.8 0.5 2.6 0.4 0.9 0.6 3.4 0.4 0.9 0.5 1.9 0.4 356 38 268 165 11.7 0.1 12.2 11.4 05/13/2006 09:00:00 1 0.5 2.6 0.4 1 0.6 3.8 0.4 0.8 0.4 1.9 0.4 298 21 244 165 11.8 0 12.2 11.7 05/13/2006 09:10:00 1.3 0.6 3 0.4 1.4 0.6 3 0.4 1.3 0.7 3.4 0.4 283 36 208 165 11.9 0.2 12.5 11.7 05/13/2006 09:20:00 2.1 0.5 3.4 1.1 2.1 0.5 3 0.7 1.7 0.4 2.6 0.7 305 10 291 165 11.1 0.5 11.9 10.3 05/13/2006 09:30:00 1.5 0.6 3 0.4 1.2 0.5 2.6 0.4 1.5 0.6 3 0.4 354 21 9 165 11.5 0.4 12.2 10.6 05/13/2006 09:40:00 2.5 0.7 4.6 1.1 2.3 0.7 4.2 1.1 2.3 0.7 3.8 0.7 329 22 344 165 11.7 0.2 11.9 10.9 05/13/2006 09:50:00 2.6 0.8 4.6 0.7 2.5 0.9 4.2 0.4 2.4 0.8 4.2 0.4 328 16 325 165 11.3 0.1 11.7 11.1 05/13/2006 10:00:00 1.2 0.6 3 0.4 1.1 0.6 3 0.4 1 0.6 2.6 0.4 328 22 337 165 11.9 0.2 12.2 11.4 05/13/2006 10:10:00 2.2 1.2 4.9 0.4 2 1.1 4.9 0.4 2 1 4.2 0.4 337 41 3 165 12.1 0.2 12.5 11.4 05/13/2006 10:20:00 3.6 0.7 6.1 2.3 3.2 0.7 5.3 1.5 3.5 0.7 5.7 1.9 333 28 0 165 12.1 0.3 12.5 11.4 05/13/2006 10:30:00 1.8 1 4.9 0.4 1.8 1 4.6 0.4 2.2 1 5.3 0.4 217 76 171 165 11.1 0.4 11.9 10.3 05/13/2006 10:40:00 1.3 0.7 3 0.4 1.3 0.7 3 0.4 1.5 0.7 3 0.4 134 66 144 165 10.7 0.1 11.1 10.3 05/13/2006 10:50:00 2.1 1.2 4.9 0.4 2.1 1.2 4.6 0.4 2.2 1.1 4.6 0.4 173 38 148 165 10.8 0.4 11.4 9.6 05/13/2006 11:00:00 2.1 0.9 4.9 0.4 2.1 0.9 4.6 0.4 2.3 0.9 4.9 0.4 155 18 143 165 9.7 0.1 10.1 9.3 05/13/2006 11:10:00 3.5 0.7 5.3 1.5 3.5 0.7 5.3 1.9 3.6 0.7 5.3 1.9 152 15 163 165 9.4 0.5 10.3 8.5 05/13/2006 11:20:00 2.8 0.7 4.6 1.1 2.8 0.7 4.9 1.1 2.9 0.7 4.6 1.1 151 18 142 165 9.2 0.2 9.6 8.8 05/13/2006 11:30:00 2.8 0.6 4.6 1.1 2.8 0.6 4.6 1.1 2.8 0.7 4.6 1.5 140 15 171 165 9.2 0.1 9.8 8.8 05/13/2006 11:40:00 3 0.6 4.6 1.1 3 0.6 4.6 1.5 3 0.7 4.9 1.1 145 15 141 165 9.9 0.1 10.3 9.6 05/13/2006 11:50:00 2.3 0.7 4.2 0.4 2.3 0.7 4.2 0.4 2.4 0.7 4.2 0.4 135 17 147 165 9.4 0.2 10.3 9 05/13/2006 12:00:00 3.1 0.7 5.3 1.5 3.2 0.7 4.9 1.5 3.2 0.6 4.9 1.5 137 15 146 165 9.1 0.3 9.6 8.5 05/13/2006 12:10:00 2.5 0.8 4.6 0.7 2.5 0.8 4.6 0.7 2.7 0.8 4.9 1.1 138 15 156 165 9.1 0.3 9.6 8.5 05/13/2006 12:20:00 2.5 1 5.3 0.7 2.5 1 5.3 0.7 2.8 0.9 5.3 0.7 146 16 147 165 9.4 0 9.6 9 05/13/2006 12:30:00 3.1 0.6 4.9 1.1 3.1 0.6 4.6 1.5 3.2 0.5 4.9 1.1 143 13 148 165 9.7 0 10.1 9.3 05/13/2006 12:40:00 3.3 0.8 4.9 1.5 3.2 0.8 4.9 1.5 3.4 0.7 5.3 1.5 159 11 149 165 9.6 0.1 10.1 9.3 05/13/2006 12:50:00 2.8 0.6 4.9 1.1 2.8 0.6 5.3 1.5 2.8 0.6 4.6 1.5 138 15 143 165 9.1 0 9.3 9 05/13/2006 13:00:00 2.5 0.6 4.2 0.7 2.5 0.6 4.2 0.7 2.6 0.6 4.6 1.5 137 18 147 165 9.2 0.1 9.6 9 05/13/2006 13:10:00 3 0.7 4.9 1.1 3 0.7 4.9 1.1 3 0.7 4.6 1.5 140 11 140 165 9.5 0.2 9.8 9 05/13/2006 13:20:00 3.3 0.7 4.9 1.5 3.3 0.7 5.3 1.5 3.4 0.7 5.3 1.9 150 12 154 165 9.4 0.1 9.6 9 05/13/2006 13:30:00 3.5 0.6 4.9 1.9 3.4 0.6 4.9 1.5 3.6 0.6 4.9 2.3 145 14 130 165 9.2 0 9.6 9 05/13/2006 13:40:00 3 0.8 5.7 1.9 3 0.8 5.7 1.5 3 0.9 5.7 1.1 145 12 145 165 9.2 0.2 9.6 9 05/13/2006 13:50:00 3.4 0.8 5.3 0.7 3.3 0.7 5.3 0.7 3.4 0.7 5.3 1.9 143 13 164 165 9.8 0.3 10.9 9.3 05/13/2006 14:00:00 3.4 0.6 5.3 2.3 3.3 0.6 5.3 1.9 3.4 0.6 5.7 2.3 137 10 151 165 9.9 0.3 10.9 9.6 05/13/2006 14:10:00 3.3 0.5 4.9 2.3 3.3 0.6 5.3 2.3 3.3 0.6 4.9 2.3 142 10 133 165 10 0.2 10.3 9.6 05/13/2006 14:20:00 3.4 0.4 4.6 2.3 3.4 0.4 4.9 2.3 3.5 0.5 5.3 2.3 140 9 141 165 10 0.2 10.6 9.6 05/13/2006 14:30:00 3.6 0.5 4.9 1.5 3.5 0.5 5.3 1.9 3.6 0.5 4.9 2.3 133 10 133 165 10.1 0.1 10.6 9.8 05/13/2006 14:40:00 3.6 0.4 4.9 2.6 3.5 0.5 4.9 2.3 3.6 0.5 5.3 2.3 137 8 130 165 10.3 0.1 10.9 10.3 05/13/2006 14:50:00 3.4 0.5 4.9 2.3 3.4 0.4 4.6 2.3 3.5 0.5 5.3 2.6 135 10 142 165 9.6 0.1 10.3 9.3 05/13/2006 15:00:00 3.4 0.4 4.9 2.3 3.4 0.5 4.9 2.3 3.5 0.5 4.9 2.6 140 10 162 165 10 0.2 10.3 9.3 05/13/2006 15:10:00 4 0.5 5.3 2.6 3.9 0.5 5.7 2.6 4 0.6 5.7 2.6 140 8 151 165 9.9 0 10.3 9.6 05/13/2006 15:20:00 4.4 0.5 6.1 3 4.4 0.6 6.1 2.6 4.4 0.5 6.1 3 139 7 143 165 10 0 10.3 9.6 05/13/2006 15:30:00 4.6 0.6 6.1 3 4.6 0.6 6.1 2.6 4.6 0.6 6.1 3 142 10 139 165 9.8 0.1 10.3 9.6 05/13/2006 15:40:00 4.9 0.6 6.8 3 4.9 0.6 6.8 3 4.9 0.6 6.8 3.4 141 9 142 165 10 0.1 10.6 9.6 05/13/2006 15:50:00 4.7 0.4 6.1 3.8 4.7 0.5 6.1 3.4 4.8 0.5 6.5 3.8 142 7 154 165 10.1 0 10.3 9.8 05/13/2006 16:00:00 4.8 0.5 6.1 3.4 4.8 0.5 6.1 3.4 4.9 0.5 6.5 3.4 141 9 141 165 10.2 0.2 10.9 9.6 05/13/2006 16:10:00 4.3 0.5 6.1 2.6 4.3 0.5 5.7 3.4 4.4 0.5 6.1 3.4 141 7 129 165 10.1 0 10.6 9.8 05/13/2006 16:20:00 4.6 0.5 5.7 3.4 4.6 0.5 6.5 3.4 4.7 0.5 6.1 3.4 142 7 147 165 10 0 10.3 9.8 05/13/2006 16:30:00 5 0.5 6.1 3 5 0.5 6.1 3 5.1 0.5 6.8 3.8 141 9 144 165 10.1 0 10.3 9.8 05/13/2006 16:40:00 4.6 0.4 5.7 3.4 4.6 0.4 5.7 3.4 4.7 0.5 6.1 3.4 134 6 129 165 9.8 0.2 10.3 9.6 05/13/2006 16:50:00 4.8 0.3 5.7 3 4.8 0.3 5.7 3.4 4.9 0.4 6.1 3.8 137 5 138 165 9.7 0.1 10.1 9.6 05/13/2006 17:00:00 4.8 0.5 6.1 3 4.8 0.5 6.1 3.4 4.9 0.5 6.8 3.4 145 7 157 165 9.8 0 10.1 9.6 05/13/2006 17:10:00 5.1 0.5 6.5 3.4 5 0.5 6.1 3.4 5.2 0.5 6.1 3.8 148 7 139 165 9.6 0.1 10.1 9.3 05/13/2006 17:20:00 5.3 0.4 6.5 3.8 5.3 0.4 6.5 4.2 5.4 0.5 6.5 3.4 145 5 140 165 9.6 0 9.8 9.3 05/13/2006 17:30:00 5 0.5 6.1 3.4 5 0.5 6.5 3.4 5 0.5 6.1 3.4 139 8 139 165 9.6 0.1 9.8 9.3 05/13/2006 17:40:00 4.5 0.7 5.7 2.3 4.5 0.7 5.7 2.6 4.5 0.7 5.7 2.6 138 9 139 165 9.5 0 9.6 9.3 05/13/2006 17:50:00 4.9 0.7 6.1 2.3 4.9 0.7 6.1 2.3 4.9 0.7 6.1 2.3 135 7 132 165 9.7 0.1 10.3 9.3 05/13/2006 18:00:00 4.6 0.5 6.1 3.4 4.7 0.5 5.7 3.4 4.6 0.5 5.7 3.4 135 7 119 165 9.6 0 9.8 9.3 05/13/2006 18:10:00 4.1 0.4 5.3 3 4.1 0.4 5.3 3 4.1 0.4 5.3 3 127 6 123 165 9.4 0 9.8 9 05/13/2006 18:20:00 4.4 0.7 5.7 3 4.4 0.6 5.7 3 4.5 0.7 5.7 2.3 135 11 119 165 9.4 0 9.6 9 05/13/2006 18:30:00 4.6 0.7 6.1 2.6 4.6 0.7 6.1 2.6 4.6 0.7 6.1 3 138 11 137 165 9.2 0.1 9.6 9 05/13/2006 18:40:00 4.5 0.6 5.7 2.6 4.5 0.5 5.7 3 4.6 0.5 6.5 3 142 12 145 165 8.8 0.1 9.6 8.5 05/13/2006 18:50:00 4.3 1.2 8 1.1 4.3 1.2 6.8 1.5 4.4 1.2 6.5 1.1 156 13 153 165 8.5 0 8.8 8.5 05/13/2006 19:00:00 4.8 0.8 6.1 2.3 4.7 0.8 6.1 2.6 4.7 0.7 6.1 2.3 154 12 156 165 8.4 0 8.8 8.3 05/13/2006 19:10:00 4.7 0.3 5.7 3.8 4.8 0.3 5.7 3.8 4.6 0.4 5.7 3.8 127 13 146 165 8.2 0 8.8 8 05/13/2006 19:20:00 2.4 1.1 4.6 0.4 2.5 1.2 4.9 0.4 3 1.1 4.9 1.1 103 17 99 165 8.3 0.2 9 8 05/13/2006 19:30:00 1.2 0.6 2.6 0.4 1.2 0.6 2.6 0.4 1.2 0.7 3 0.4 170 107 128 165 9.9 0.5 10.6 9 05/13/2006 19:40:00 0.8 0.6 2.3 0.4 0.8 0.6 2.3 0.4 0.8 0.6 2.3 0.4 323 36 351 165 10.5 0 11.1 10.3 05/13/2006 19:50:00 0.8 0.5 1.9 0.4 0.8 0.5 1.9 0.4 0.7 0.5 1.9 0.4 243 47 199 165 10.6 0.2 10.9 9.8 05/13/2006 20:00:00 1.8 0.3 2.6 1.1 1.8 0.3 2.6 1.1 1.7 0.3 2.6 0.7 216 17 232 165 9.5 0.3 10.3 9 05/13/2006 20:10:00 2.3 0.3 3 1.5 2.2 0.2 2.6 1.5 2.2 0.3 3 1.5 172 7 169 165 8.9 0 9 8.5 05/13/2006 20:20:00 2.5 0.3 4.2 1.9 2.4 0.4 4.2 1.5 2.4 0.3 3.8 1.9 143 15 135 165 8.5 0 8.8 8 05/13/2006 20:30:00 3.1 0.3 3.8 2.3 3 0.3 3.8 2.3 3 0.4 3.8 2.3 157 8 131 165 8 0 8.3 7.5 05/13/2006 20:40:00 3.2 0.3 3.8 2.3 3.1 0.4 3.8 2.3 3 0.4 4.2 1.9 152 9 159 165 7.6 0.1 7.8 7.3 05/13/2006 20:50:00 3.6 0.3 4.6 2.6 3.5 0.3 4.6 2.6 3.6 0.3 4.9 3 142 11 123 165 7.1 0.1 7.3 7 05/13/2006 21:00:00 3.3 0.3 4.2 2.3 3.3 0.3 4.2 2.6 3.4 0.3 4.2 2.6 144 8 137 165 6.7 0 7 6.2 05/13/2006 21:10:00 3.6 0.4 4.2 2.6 3.6 0.4 4.2 2.6 3.6 0.4 4.6 2.3 146 15 148 165 6.2 0 6.7 6 05/13/2006 21:20:00 3.1 0.4 4.2 1.9 3.2 0.4 4.2 1.9 3.3 0.4 4.2 1.9 135 10 131 165 6.1 0 6.2 6 05/13/2006 21:30:00 3.8 0.4 4.6 2.6 3.8 0.4 4.6 2.6 3.7 0.4 4.6 2.6 141 7 132 165 6.3 0 6.5 6 05/13/2006 21:40:00 3.8 0.3 4.6 3 3.8 0.3 4.6 3 3.8 0.3 4.6 3 141 7 126 165 6 0.1 6.2 5.7 05/13/2006 21:50:00 4.2 0.4 5.3 3.4 4.1 0.4 4.9 3.4 4.2 0.4 5.3 3 158 6 161 165 5.8 0 6 5.7 05/13/2006 22:00:00 3.5 0.4 4.2 2.6 3.4 0.3 4.2 2.6 3.4 0.4 4.2 2.6 162 4 164 165 5.7 0 6 5.7 05/13/2006 22:10:00 3.8 0.3 4.6 3 3.7 0.2 4.2 3 3.5 0.3 4.2 2.6 172 7 180 165 5.9 0 6 5.5 05/13/2006 22:20:00 3.9 0.2 4.2 3 3.8 0.2 4.2 3 3.8 0.4 4.6 3 180 3 181 165 6.4 0.1 6.7 5.7 05/13/2006 22:30:00 3.7 0.2 4.2 3.4 3.6 0.2 4.2 3.4 3.8 0.2 4.2 3.4 167 4 169 165 6.9 0.1 7.3 6.2 05/13/2006 22:40:00 3.4 0.3 4.2 2.6 3.3 0.3 4.2 2.6 3 0.3 3.8 2.3 162 6 171 165 6.5 0.3 7.3 6 05/13/2006 22:50:00 3.4 0.4 4.2 2.3 3.3 0.3 3.8 2.3 2.9 0.4 3.8 1.9 174 6 179 165 6.2 0 6.2 5.7 05/13/2006 23:00:00 3.2 0.5 4.2 2.3 3.2 0.4 3.8 2.3 2.9 0.5 4.2 1.9 176 6 179 165 6.3 0.1 6.7 5.7 05/13/2006 23:10:00 3.5 0.3 4.2 2.3 3.4 0.3 4.2 2.3 3.2 0.5 4.2 1.5 186 6 179 165 6.6 0 6.7 6.2 05/13/2006 23:20:00 2.9 0.5 3.8 1.5 2.9 0.4 4.2 1.9 2.4 0.4 3.4 1.5 183 8 183 165 6.5 0.1 6.7 6.2 05/13/2006 23:30:00 3.5 0.3 4.2 2.3 3.5 0.3 4.2 2.6 3.1 0.3 3.8 2.3 186 4 176 165 6.4 0.1 6.7 6 05/13/2006 23:40:00 3.7 0.4 4.6 2.6 3.7 0.4 4.6 2.6 3.4 0.5 4.6 2.3 190 5 194 165 6.5 0.1 6.7 6 05/13/2006 23:50:00 3.5 0.4 4.6 2.6 3.5 0.3 4.6 2.6 3.3 0.3 4.2 2.6 181 6 178 165 6.3 0.2 6.7 5.7 05/14/2006 00:00:00 3.7 0.6 5.3 2.6 3.7 0.6 5.7 2.6 3.5 0.5 5.7 2.3 184 8 197 165 6.3 0.1 6.5 6 05/14/2006 00:10:00 3.2 0.4 4.6 2.3 3.2 0.4 4.6 2.3 3 0.4 4.2 1.9 183 9 180 165 6.2 0 6.7 6 05/14/2006 00:20:00 3.8 0.4 4.9 2.6 3.9 0.4 4.9 2.6 3.6 0.5 4.6 2.3 199 7 206 165 6.4 0 6.7 6 05/14/2006 00:30:00 3.2 0.4 3.8 1.9 3.3 0.5 4.2 1.9 3 0.6 4.2 1.5 214 7 210 165 6.4 0 7 6 05/14/2006 00:40:00 2.9 0.2 3.4 2.6 3.1 0.2 3.4 2.6 3 0.2 3.4 2.3 218 6 225 165 6.7 0.1 7.3 6.2 05/14/2006 00:50:00 2.6 0.3 3 1.9 2.7 0.3 3.4 1.9 2.2 0.5 3 1.1 204 6 201 165 6.6 0.3 7.5 6 05/14/2006 01:00:00 1.3 0.8 2.6 0.4 1.4 0.9 3 0.4 1 0.8 3 0.4 224 33 215 165 6 0.2 6.2 5.5 05/14/2006 01:10:00 1.9 0.3 3.4 1.1 1.9 0.4 3 1.1 1.8 0.5 3 1.1 295 12 284 165 6.1 0 6.2 5.7 05/14/2006 01:20:00 1.9 0.2 2.6 1.5 1.6 0.3 2.6 0.7 1.8 0.4 2.6 1.1 341 15 355 165 5.7 0.1 6 5.5 05/14/2006 01:30:00 0.9 0.6 2.3 0.4 0.9 0.5 1.9 0.4 0.8 0.6 2.3 0.4 85 64 2 165 5.7 0.2 6.2 5.5 05/14/2006 01:40:00 0.4 0.1 1.1 0.4 0.4 0.2 1.1 0.4 0.4 0.1 1.1 0.4 114 13 121 165 5.8 0.1 6.2 5.7 05/14/2006 01:50:00 0.5 0.2 1.5 0.4 0.5 0.2 1.5 0.4 0.4 0 0.7 0.4 42 43 15 165 5.6 0 5.7 5.5 05/14/2006 02:00:00 0.4 0.1 1.1 0.4 0.4 0.1 1.1 0.4 0.4 0 0.4 0.4 38 0 38 165 5.7 0 6 5.7 05/14/2006 02:10:00 0.4 0 0.4 0.4 0.4 0.2 1.1 0.4 0.4 0 0.4 0.4 340 102 165 165 5.7 0 5.7 5.5 05/14/2006 02:20:00 1.2 0.5 2.3 0.4 1.4 0.4 2.3 0.7 1.1 0.7 2.3 0.4 169 6 180 165 5.6 0 5.7 5.2 05/14/2006 02:30:00 1.4 0.2 2.3 0.7 1.5 0.2 1.9 1.1 1.3 0.3 1.9 0.7 164 4 164 165 5.2 0.1 5.7 4.8 05/14/2006 02:40:00 1.7 0.4 2.6 0.7 1.8 0.4 2.6 1.1 1.4 0.5 2.6 0.4 173 8 177 165 4.9 0.1 5.2 4.5 05/14/2006 02:50:00 2.5 0.6 4.2 1.5 2.6 0.6 4.6 1.5 2.2 0.5 3.8 1.1 184 9 205 165 5.2 0.1 5.5 4.8 05/14/2006 03:00:00 3.6 0.8 5.3 1.9 3.5 0.7 5.3 1.9 3.2 0.8 5.3 1.9 187 6 187 165 4.9 0 5.2 4.8 05/14/2006 03:10:00 5 0.6 6.5 3.8 4.9 0.6 6.5 3.8 4.9 0.6 6.5 3.8 192 7 199 165 4.8 0.1 5 4.5 05/14/2006 03:20:00 5.3 0.6 6.8 3.8 5.3 0.6 6.8 3.8 5.3 0.6 6.8 3.4 192 7 198 165 4.4 0.1 4.8 4 05/14/2006 03:30:00 4.4 0.5 5.3 3.4 4.3 0.5 5.3 3.4 4.3 0.5 5.7 3.4 181 4 181 165 4.2 0.1 4.5 3.8 05/14/2006 03:40:00 3.6 0.4 4.9 2.6 3.6 0.4 4.6 2.6 3.4 0.3 4.2 2.3 181 6 189 165 4.2 0 4.8 3.8 05/14/2006 03:50:00 4 0.8 6.5 2.6 4 0.8 6.5 2.6 3.8 0.8 6.1 2.3 181 10 193 165 4.2 0.1 4.5 3.8 05/14/2006 04:00:00 5.2 0.7 7.2 2.3 5.2 0.7 7.2 2.3 5.2 0.7 6.8 3.4 187 10 201 165 4.2 0.1 4.5 3.8 05/14/2006 04:10:00 5.5 0.6 6.8 3.8 5.5 0.6 6.8 3.8 5.6 0.7 7.2 3.8 190 6 192 165 4.2 0.1 4.5 4 05/14/2006 04:20:00 5.6 0.4 6.5 4.9 5.7 0.4 6.8 4.9 5.7 0.5 6.8 4.6 198 4 201 165 4.1 0.1 4.5 3.8 05/14/2006 04:30:00 6 0.5 6.8 4.9 6.2 0.5 6.8 4.9 6.1 0.6 7.6 4.9 199 3 202 165 4.3 0 4.5 4 05/14/2006 04:40:00 4.8 0.4 5.7 3.8 4.8 0.4 5.7 3.8 4.6 0.4 5.7 3.4 193 4 196 165 4 0.2 4.5 3.5 05/14/2006 04:50:00 5.4 0.4 6.1 4.2 5.5 0.4 6.1 4.2 5.4 0.5 6.5 3.8 194 3 196 165 4.1 0.2 4.5 3.5 05/14/2006 05:00:00 5.1 0.6 6.8 3.8 5.1 0.6 6.8 3.8 5 0.5 6.8 3.4 188 5 194 165 4.1 0.2 4.5 3.5 05/14/2006 05:10:00 5 1 6.8 3 4.9 1 6.5 3 4.8 1 6.8 3 180 7 189 165 4 0.1 4.5 3.5 05/14/2006 05:20:00 4.5 0.7 6.8 3 4.4 0.7 6.8 3 4.3 0.6 6.5 3 178 8 184 165 4 0.2 4.5 3.5 05/14/2006 05:30:00 5.1 0.8 6.8 3.4 5 0.7 6.5 3.4 4.9 0.7 6.8 3.4 178 7 180 165 4.3 0.1 4.5 3.8 05/14/2006 05:40:00 5.5 0.5 6.8 4.2 5.3 0.5 6.5 4.2 5.2 0.6 6.8 3.4 182 6 181 165 4.3 0.1 4.8 4 05/14/2006 05:50:00 4.1 0.8 7.2 2.3 4.1 0.8 6.8 2.3 4 0.6 6.1 2.3 178 9 193 165 4.4 0.1 5 4.3 05/14/2006 06:00:00 4.8 0.6 7.2 3 4.7 0.5 6.8 3 4.9 0.5 6.1 3.4 177 9 178 165 4.6 0.1 5 4.3 05/14/2006 06:10:00 4.8 0.7 6.5 3.4 4.6 0.7 6.1 3 4.9 0.6 6.8 3.4 179 9 179 165 4.9 0 5 4.5 05/14/2006 06:20:00 4.9 0.7 6.5 2.6 4.8 0.6 6.5 2.6 5 0.6 6.5 3 183 9 180 165 5.1 0.1 5.2 4.8 05/14/2006 06:30:00 4.9 0.6 6.1 3.4 4.8 0.5 6.1 3.4 5.2 0.5 6.5 3.4 178 9 174 165 5.1 0 5.5 4.8 05/14/2006 06:40:00 5.3 0.6 6.8 3.4 5.2 0.6 7.2 3.4 5.5 0.7 6.8 3.4 177 9 177 165 5.2 0.1 5.7 5 05/14/2006 06:50:00 5.7 0.6 6.8 4.2 5.5 0.5 6.5 4.2 6 0.6 7.2 4.6 178 7 165 165 4.9 0.1 5.2 4.5 05/14/2006 07:00:00 5 0.6 6.5 3.8 4.9 0.6 6.5 3.4 5.1 0.6 7.2 3.8 183 9 173 165 5.2 0.1 5.5 4.8 05/14/2006 07:10:00 5.7 0.9 8.8 3.8 5.7 0.8 8.4 3.8 5.8 0.8 8.8 4.2 179 8 176 165 5.2 0 5.5 5 05/14/2006 07:20:00 6.7 0.7 8.8 4.6 6.5 0.7 8.8 4.6 6.9 0.7 8.4 5.3 178 8 182 165 5.2 0 5.5 5 05/14/2006 07:30:00 7.5 0.9 9.5 5.3 7.4 0.8 9.5 5.3 7.7 0.9 9.9 5.3 181 8 167 165 5.2 0 5.5 5 05/14/2006 07:40:00 7.8 1 9.9 4.9 7.6 1 9.9 4.9 7.9 1 10.3 5.3 182 8 173 165 5.2 0 5.5 5 05/14/2006 07:50:00 8 1 10.7 5.3 8 1 10.7 5.3 8.2 1 10.7 5.7 183 8 185 165 5.1 0.1 5.5 4.8 05/14/2006 08:00:00 7 0.9 9.1 4.6 7 0.9 9.1 4.9 7 1 9.5 4.6 188 9 196 165 5.5 0.1 6 5.2 05/14/2006 08:10:00 6.8 0.9 9.9 4.9 6.9 0.9 9.9 4.6 7.1 1 10.3 4.9 191 12 193 165 5.9 0 6.2 5.2 05/14/2006 08:20:00 6.7 0.9 9.1 4.2 6.7 0.8 9.1 4.2 6.9 0.8 8.8 4.9 185 12 210 165 6.1 0 6.5 5.7 05/14/2006 08:30:00 7.5 0.8 8.8 4.9 7.5 0.8 9.1 5.3 7.8 0.8 9.5 5.7 191 9 194 165 5.9 0.1 6.2 5.5 05/14/2006 08:40:00 7.8 1 11.1 4.9 7.7 1 10.7 4.9 8.1 1.1 10.7 5.3 183 13 168 165 6.6 0.4 7.3 5.5 05/14/2006 08:50:00 7.5 0.9 9.5 4.6 7.4 0.9 9.5 4.9 7.9 0.9 9.9 4.6 183 11 181 165 6.4 0.2 6.7 5.7 05/14/2006 09:00:00 8.2 1 9.9 4.9 8.1 0.9 9.5 4.9 8.5 1.1 10.3 5.7 173 9 165 165 5.6 0.1 6 5 05/14/2006 09:10:00 9.7 0.7 11.5 8 9.4 0.6 11.1 7.2 10 0.8 11.8 8 170 9 165 165 5.4 0 5.7 4.8 05/14/2006 09:20:00 10.3 0.6 11.8 8 10 0.6 11.5 8 10.6 0.7 12.2 8 172 10 164 165 5.6 0.3 6 4.8 05/14/2006 09:30:00 10.2 0.7 11.5 8.4 9.9 0.6 11.5 8.4 10.4 0.8 13 8.4 171 5 174 165 5.5 0.1 6 5 05/14/2006 09:40:00 8.9 0.7 10.3 6.1 8.7 0.7 10.3 6.1 9.3 0.8 11.1 6.5 173 9 167 165 5.5 0 5.7 5 05/14/2006 09:50:00 9.4 0.8 10.7 6.8 9.2 0.8 10.7 6.5 9.8 0.8 11.5 7.6 173 5 170 165 5.5 0 5.7 5.2 05/14/2006 10:00:00 9.6 0.9 12.2 7.6 9.4 0.8 11.5 7.2 9.9 1 12.2 7.6 172 8 170 165 5.6 0.2 6 5.2 05/14/2006 10:10:00 9.3 0.8 12.2 7.2 9.1 0.7 11.8 7.6 9.6 0.7 12.2 7.6 172 7 176 165 6.2 0.2 6.7 5.7 05/14/2006 10:20:00 8.9 0.6 10.7 7.6 8.7 0.6 10.3 7.2 9.2 0.7 11.1 7.6 172 5 170 165 6.2 0.2 6.7 5.5 05/14/2006 10:30:00 9.3 0.8 11.8 7.2 9.1 0.8 11.8 7.2 9.6 0.9 12.2 7.6 171 8 168 165 6.5 0 6.7 6 05/14/2006 10:40:00 10.4 0.9 12.2 8 10.2 0.8 12.2 8 10.9 0.9 13.3 8 168 9 163 165 6.4 0.1 6.7 6 05/14/2006 10:50:00 11.7 0.7 13.3 9.5 11.3 0.7 13 9.1 12.1 0.8 13.7 9.9 168 13 162 165 6.2 0.3 7 5.5 05/14/2006 11:00:00 12.3 0.6 13.7 10.7 12 0.6 13.3 10.3 12.8 0.6 14.1 10.7 167 16 162 165 6.7 0.4 7.3 5.5 05/14/2006 11:10:00 11.9 0.8 13.7 10.3 11.6 0.7 13.3 9.9 12.3 0.8 14.1 10.3 167 12 176 165 5.9 0.2 6.2 5.7 05/14/2006 11:20:00 11.3 0.7 12.6 9.1 10.9 0.6 12.2 9.1 11.6 0.7 13.3 9.1 168 9 167 165 5.5 0.1 5.7 5 05/14/2006 11:30:00 11.2 0.7 12.6 9.5 10.9 0.6 12.6 9.1 11.6 0.7 13 9.5 169 15 281 165 5.9 0.2 6.2 5.2 05/14/2006 11:40:00 12 0.5 13.3 10.3 11.6 0.5 12.6 10.3 12.4 0.5 13.7 11.1 167 5 165 165 5.6 0.2 6 5 05/14/2006 11:50:00 11 0.5 12.2 9.1 10.7 0.5 12.2 8.8 11.4 0.5 12.6 9.5 166 13 162 165 5.7 0.2 6.2 5 05/14/2006 12:00:00 10.9 0.6 12.2 9.1 10.6 0.5 11.8 9.1 11.2 0.6 12.6 9.5 167 17 164 165 6.1 0.2 6.7 5.5 05/14/2006 12:10:00 11.3 0.7 13 9.1 11.1 0.6 12.6 9.5 11.7 0.8 13.3 9.1 168 7 165 165 6.6 0.1 7 6.2 05/14/2006 12:20:00 12.1 0.8 14.1 9.9 11.8 0.7 13.3 9.9 12.5 0.8 14.5 9.9 171 15 165 165 6.1 0 6.2 5.5 05/14/2006 12:30:00 12.5 0.7 14.1 10.7 12.1 0.6 13.7 10.3 12.8 0.8 14.5 10.3 171 8 167 165 5.9 0.2 6.2 5.5 05/14/2006 12:40:00 12.2 0.6 13.7 10.3 11.8 0.5 13.7 10.3 12.6 0.7 13.7 10.7 168 7 171 165 6 0.2 6.2 5.5 05/14/2006 12:50:00 11.8 0.6 13.7 9.9 11.5 0.6 13.3 9.5 12.2 0.8 14.5 9.9 169 11 175 165 6.1 0.1 6.2 5.5 05/14/2006 13:00:00 12.9 0.8 14.9 10.7 12.5 0.7 14.5 10.7 13.2 0.8 15.6 10.3 170 10 172 165 5.8 0.2 6.2 5 05/14/2006 13:10:00 13.4 0.6 14.5 11.1 13 0.6 14.1 11.1 13.8 0.7 15.3 11.5 172 4 165 165 5.6 0 6.2 5.2 05/14/2006 13:20:00 13.1 1 14.9 9.9 12.8 0.9 14.9 9.9 13.3 1 14.9 10.7 170 9 170 165 5.7 0.1 6 5.5 05/14/2006 13:30:00 12.2 1 14.5 8.4 11.9 1 14.1 8.4 12.3 1.2 14.9 8.4 172 11 173 165 5.7 0.2 6 5 05/14/2006 13:40:00 11.8 1 13.3 9.1 11.6 0.8 13 8.8 12.1 1.1 14.1 9.5 171 9 172 165 5.7 0.2 6.2 5.2 05/14/2006 13:50:00 11.9 0.7 13.3 9.5 11.6 0.6 13.3 9.5 12 0.9 13.7 9.5 171 6 175 165 5.7 0.1 6 5 05/14/2006 14:00:00 11.5 0.7 13 9.5 11.2 0.6 13 9.9 11.8 0.7 13.7 9.9 169 15 177 165 5.9 0.1 6.2 5.5 05/14/2006 14:10:00 11.6 0.6 12.6 9.9 11.3 0.5 12.6 9.9 11.9 0.7 13.3 9.9 168 17 167 165 5.7 0.1 6 5.5 05/14/2006 14:20:00 11.7 0.7 13.7 9.9 11.4 0.6 13 9.5 12 0.7 13.7 9.9 168 4 165 165 5.7 0.1 6 5.2 05/14/2006 14:30:00 11.5 0.6 13 9.1 11.1 0.6 12.6 9.5 11.8 0.6 13.3 9.1 168 9 171 165 5.7 0 6 5.5 05/14/2006 14:40:00 10.9 0.8 12.6 8.4 10.7 0.7 12.6 8.4 11.1 0.9 13 8.8 171 5 174 165 5.9 0 6.2 5.2 05/14/2006 14:50:00 11 0.7 12.6 8 10.7 0.6 12.2 8.4 11.2 0.9 13.3 8.4 170 7 165 165 5.7 0.1 6 5.5 05/14/2006 15:00:00 11.3 0.5 12.6 9.5 11 0.4 12.2 9.5 11.6 0.6 13 9.5 167 10 179 165 5.7 0 6 5.5 05/14/2006 15:10:00 11 0.6 12.6 8.8 10.8 0.5 12.2 9.1 11.2 0.7 13 9.1 167 13 164 165 6 0.1 6.2 5.2 05/14/2006 15:20:00 11.5 0.5 13 9.9 11.1 0.5 12.6 9.9 11.8 0.6 13 9.9 167 10 167 165 5.8 0.1 6.2 5.2 05/14/2006 15:30:00 11.1 0.6 12.6 9.1 10.8 0.6 11.8 9.1 11.4 0.6 13 9.5 169 4 177 165 5.7 0.1 6 5.2 05/14/2006 15:40:00 10.6 0.8 12.2 8.8 10.3 0.7 11.8 8.8 10.9 0.8 12.6 8.8 169 13 165 165 5.9 0.1 6.2 5 05/14/2006 15:50:00 10.6 0.6 12.2 8.4 10.4 0.5 12.2 8.8 10.9 0.6 12.6 9.1 167 4 169 165 5.7 0.1 6 5.2 05/14/2006 16:00:00 9.8 0.8 11.5 8 9.6 0.7 11.1 7.6 10 0.9 11.8 7.6 170 10 166 165 5.7 0.1 6 5.5 05/14/2006 16:10:00 9.6 0.5 10.7 8 9.4 0.4 10.7 8 9.9 0.5 11.1 8.4 169 11 165 165 5.8 0.1 6 5.2 05/14/2006 16:20:00 9.8 0.5 11.1 8 9.5 0.5 10.7 8 10 0.6 11.1 8.4 170 5 165 165 5.5 0 5.7 5 05/14/2006 16:30:00 9.9 0.7 11.5 8 9.7 0.6 11.5 8 10.2 0.7 11.8 8.4 169 10 175 165 5.6 0.1 5.7 4.8 05/14/2006 16:40:00 10.3 0.6 11.5 8.4 10 0.5 11.1 8.4 10.6 0.7 12.2 8 174 4 175 165 5.4 0 5.7 4.8 05/14/2006 16:50:00 10.5 0.5 12.2 8 10.2 0.5 11.8 8 10.9 0.5 12.6 8.8 173 5 174 165 5.3 0 5.5 4.8 05/14/2006 17:00:00 10 0.5 11.5 8 9.8 0.5 11.1 8.4 10.3 0.6 11.5 8 173 4 165 165 5.6 0.1 5.7 5.2 05/14/2006 17:10:00 10.1 0.7 11.5 8 9.8 0.7 11.1 7.6 10.4 0.8 11.8 8 168 6 166 165 5.6 0.2 6 4.8 05/14/2006 17:20:00 10.5 0.6 11.8 8.8 10.2 0.5 11.5 8.8 10.8 0.6 12.2 8.8 169 5 170 165 5.3 0 5.5 5 05/14/2006 17:30:00 10 0.6 11.5 8.4 9.7 0.5 10.7 8 10.3 0.7 11.8 8 175 4 175 165 5.3 0.1 5.7 5 05/14/2006 17:40:00 9.9 0.4 10.7 8.8 9.6 0.4 10.7 8.4 10.3 0.5 11.5 8.8 173 4 173 165 5.6 0.2 6 5 05/14/2006 17:50:00 9.7 0.7 11.5 8 9.4 0.6 11.1 8 10 0.7 11.8 8 171 7 173 165 5.8 0.1 6.2 5.2 05/14/2006 18:00:00 10 0.6 11.1 8 9.7 0.5 10.7 8 10.3 0.7 11.8 8 168 9 162 165 5.6 0.2 6 5.2 05/14/2006 18:10:00 9.8 0.7 11.5 7.6 9.5 0.6 11.1 7.6 10 0.7 11.8 8 169 10 167 165 5.6 0.2 6 5.2 05/14/2006 18:20:00 10.2 0.5 11.5 8.8 9.9 0.5 11.5 8.4 10.5 0.6 12.2 8.8 170 9 179 165 5.7 0.1 6 5 05/14/2006 18:30:00 10 0.5 11.1 8.4 9.7 0.5 10.7 8.4 10.3 0.5 11.5 8.4 169 5 170 165 5.6 0.1 5.7 5 05/14/2006 18:40:00 10.4 0.5 11.5 8.8 10.1 0.5 11.1 8.8 10.6 0.6 11.8 8.8 169 5 165 165 5.4 0.1 5.7 5 05/14/2006 18:50:00 10.7 0.6 11.8 9.1 10.4 0.5 11.5 9.1 11 0.7 12.6 9.1 168 8 171 165 5.1 0.1 5.5 4.8 05/14/2006 19:00:00 10.1 0.5 11.1 8.8 9.9 0.4 11.1 8.8 10.4 0.5 11.8 8.8 169 8 170 165 5.2 0.1 5.5 4.5 05/14/2006 19:10:00 9.5 0.6 10.7 8 9.2 0.5 10.7 7.6 9.8 0.6 11.1 8 171 8 177 165 4.8 0.1 5.2 4.3 05/14/2006 19:20:00 9.7 0.5 10.7 7.6 9.5 0.4 10.7 7.6 10 0.6 11.5 7.6 174 4 173 165 4.6 0.2 5 4.3 05/14/2006 19:30:00 9.6 0.5 10.7 8 9.4 0.5 10.3 8 9.9 0.6 11.5 7.6 170 6 170 165 4.6 0.2 5.2 4 05/14/2006 19:40:00 9.2 0.6 10.7 7.2 9 0.6 10.3 7.2 9.3 0.7 11.1 7.2 171 5 174 165 4.5 0.2 4.8 3.8 05/14/2006 19:50:00 9.6 0.6 11.1 7.6 9.4 0.6 10.7 7.6 9.8 0.7 11.8 8 171 4 173 165 4.6 0.2 5 4.3 05/14/2006 20:00:00 9.7 0.5 11.5 8 9.4 0.5 11.1 8.4 9.9 0.6 11.8 7.6 172 4 171 165 4.6 0.2 5 4.3 05/14/2006 20:10:00 9.2 0.8 11.1 7.2 9 0.7 10.7 7.2 9.4 0.8 11.5 6.8 172 5 173 165 4.4 0.2 4.8 3.8 05/14/2006 20:20:00 8.1 0.6 9.5 6.1 7.9 0.5 9.5 6.1 8.2 0.7 9.5 6.5 172 5 173 165 4.4 0.1 4.8 3.8 05/14/2006 20:30:00 8 0.6 9.1 6.5 7.8 0.6 9.1 6.1 8.3 0.7 9.5 6.5 169 4 167 165 4.4 0 4.8 4.3 05/14/2006 20:40:00 8.3 0.6 9.5 6.8 8.1 0.5 9.1 6.8 8.5 0.7 9.9 6.8 173 9 172 165 4.3 0 4.5 4.3 05/14/2006 20:50:00 8.7 0.5 9.9 7.2 8.5 0.5 9.9 7.2 9 0.5 10.3 7.2 170 4 173 165 4.3 0 4.5 3.8 05/14/2006 21:00:00 9.1 0.7 10.7 6.8 8.9 0.6 10.7 6.8 9.3 0.7 10.7 7.6 174 5 176 165 4.1 0 4.5 3.8 05/14/2006 21:10:00 7.2 0.8 9.1 4.9 7.1 0.8 9.1 4.9 7.6 0.8 9.5 5.3 177 5 165 165 4.1 0.1 4.3 3.5 05/14/2006 21:20:00 5.7 0.5 6.5 4.2 5.8 0.5 6.8 3.8 6 0.5 7.2 4.2 191 5 192 165 3.8 0.1 4.3 3.3 05/14/2006 21:30:00 5.7 0.4 6.5 4.6 5.7 0.3 6.5 4.9 6 0.4 6.8 4.9 187 4 183 165 3.6 0.1 3.8 3 05/14/2006 21:40:00 5.8 0.4 6.8 4.6 5.8 0.4 6.5 4.6 6 0.4 6.8 4.9 182 4 181 165 3.5 0.2 3.8 2.8 05/14/2006 21:50:00 5.1 0.4 5.7 4.2 5.1 0.3 6.1 4.2 5.4 0.5 6.5 4.2 184 5 185 165 3.5 0.2 3.8 2.8 05/14/2006 22:00:00 5.2 0.3 6.1 4.6 5.1 0.3 5.7 4.6 5.4 0.3 6.1 4.6 178 3 174 165 3.4 0 3.8 2.8 05/14/2006 22:10:00 5.2 0.3 6.1 4.6 5.2 0.3 6.1 4.6 5.5 0.3 6.1 4.6 180 3 180 165 3.3 0 3.5 2.8 05/14/2006 22:20:00 4.9 0.3 5.7 4.2 4.9 0.3 5.3 4.2 5.1 0.2 5.7 4.6 183 2 180 165 3.3 0 3.5 2.8 05/14/2006 22:30:00 5.1 0.4 6.1 4.2 5.2 0.3 6.5 4.2 5.4 0.4 6.5 4.2 185 3 182 165 3.3 0 3.5 3 05/14/2006 22:40:00 5.2 0.3 6.1 4.2 5.2 0.3 6.1 4.6 5.5 0.3 6.1 4.6 184 3 190 165 3.3 0 3.5 3 05/14/2006 22:50:00 5.1 0.2 5.7 4.6 5.1 0.2 6.1 4.6 5.4 0.2 6.1 4.9 188 3 185 165 3.3 0 3.5 2.8 05/14/2006 23:00:00 5.2 0.3 6.1 4.6 5.4 0.2 6.1 4.6 5.6 0.3 6.5 4.9 193 4 192 165 3.4 0 3.5 2.8 05/14/2006 23:10:00 5.1 0.3 6.5 4.2 5.3 0.3 6.5 4.6 5.5 0.3 6.1 4.6 199 4 188 165 3.4 0 3.5 3.3 05/14/2006 23:20:00 5.3 0.4 6.5 4.6 5.5 0.4 6.8 4.9 5.6 0.4 6.8 4.6 197 3 204 165 3.4 0 3.5 3.3 05/14/2006 23:30:00 5.4 0.4 6.5 4.6 5.6 0.4 6.8 4.6 5.8 0.4 6.8 4.9 194 3 192 165 3.4 0 3.5 3.3 05/14/2006 23:40:00 5.1 0.4 6.1 4.2 5.3 0.4 6.1 4.2 5.2 0.5 6.1 4.2 197 5 197 165 3.3 0 3.5 3 05/14/2006 23:50:00 5 0.4 6.1 4.2 5.2 0.4 6.1 4.2 5.1 0.5 6.5 4.2 205 4 204 165 3.1 0 3.3 2.8 05/15/2006 00:00:00 5.2 0.5 6.1 3.8 5.4 0.5 6.5 3.8 5.3 0.5 6.5 4.2 204 3 208 165 3 0 3.5 2.8 05/15/2006 00:10:00 5.7 0.3 6.5 4.9 5.8 0.3 6.5 4.9 6 0.3 6.8 4.9 194 3 195 165 3.1 0 3.3 2.8 05/15/2006 00:20:00 5.5 0.3 6.1 4.6 5.6 0.3 6.5 4.6 5.9 0.3 6.8 4.9 187 4 191 165 3 0.1 3.3 2.8 05/15/2006 00:30:00 5.1 0.4 6.1 4.2 5.1 0.3 6.1 4.2 5.4 0.4 6.5 4.6 185 4 194 165 3 0 3.3 2.8 05/15/2006 00:40:00 4.6 0.3 5.3 4.2 4.5 0.3 5.3 3.8 4.8 0.3 5.7 4.2 181 4 184 165 3 0.1 3.3 2.6 05/15/2006 00:50:00 4.8 0.4 6.1 3.4 4.7 0.4 5.7 3.8 4.8 0.4 6.1 3.8 174 4 183 165 3 0.1 3.3 2.6 05/15/2006 01:00:00 4.7 0.4 5.7 3.8 4.6 0.3 5.7 3.8 4.6 0.3 5.7 3.8 174 3 179 165 3 0 3.3 2.8 05/15/2006 01:10:00 5.3 0.4 6.1 4.2 5.2 0.4 6.1 4.2 5.3 0.4 6.1 4.2 174 4 182 165 3 0 3.3 2.8 05/15/2006 01:20:00 4.9 0.3 5.7 4.2 4.9 0.3 5.7 4.2 5.2 0.3 6.1 4.6 182 3 176 165 3 0 3.3 2.8 05/15/2006 01:30:00 4.5 0.5 5.7 3.4 4.5 0.5 5.7 3.4 4.8 0.5 5.7 3.8 186 3 185 165 3 0 3.3 2.8 05/15/2006 01:40:00 3.6 0.2 4.2 3 3.6 0.2 4.2 3 3.8 0.2 4.2 3.4 181 2 178 165 2.9 0 3 2.8 05/15/2006 01:50:00 4 0.2 4.6 3.4 4.1 0.2 4.6 3.4 4.3 0.2 4.9 3.8 186 3 187 165 2.9 0 3 2.8 05/15/2006 02:00:00 4.2 0.2 4.6 3.8 4.2 0.2 4.6 3.8 4.4 0.2 4.9 3.8 180 2 180 165 2.8 0 3 2.6 05/15/2006 02:10:00 3.7 0.3 4.2 3.4 3.7 0.3 4.2 3.4 4.1 0.2 4.6 3.4 181 1 179 165 2.9 0 3 2.6 05/15/2006 02:20:00 4.2 0.4 4.9 3.4 4.3 0.4 4.9 3.4 4.5 0.4 5.3 3.8 185 3 192 165 2.9 0 3 2.8 05/15/2006 02:30:00 4.6 0.3 5.3 3.8 4.7 0.2 4.9 4.2 4.8 0.3 5.3 4.2 186 2 181 165 2.9 0 3 2.8 05/15/2006 02:40:00 3.6 0.4 4.9 2.3 3.8 0.4 4.9 2.6 3.7 0.4 4.9 2.6 195 5 192 165 2.9 0 3.3 2.8 05/15/2006 02:50:00 3.7 0.5 4.6 2.3 3.7 0.5 4.6 2.6 3.8 0.5 4.9 2.6 193 7 191 165 3 0.1 3.3 2.8 05/15/2006 03:00:00 3.5 0.4 4.6 2.3 3.6 0.4 4.6 2.3 3.7 0.5 4.9 2.3 209 7 200 165 2.9 0 3 2.6 05/15/2006 03:10:00 4 0.4 4.9 3 4.2 0.4 5.3 3 4.1 0.4 5.3 3 218 4 223 165 2.7 0 2.8 2.3 05/15/2006 03:20:00 4.3 0.3 4.9 3.8 4.6 0.3 5.3 3.8 4.5 0.3 5.3 3.4 218 3 222 165 2.8 0 3 2.3 05/15/2006 03:30:00 4.1 0.3 4.9 2.6 4.3 0.3 4.9 3 4.1 0.4 5.3 2.6 224 4 213 165 2.7 0 3 2.3 05/15/2006 03:40:00 3.5 0.4 4.6 2.3 3.7 0.4 4.6 3 3.6 0.4 4.6 2.3 238 6 234 165 2.9 0 3 2.3 05/15/2006 03:50:00 3.6 0.2 4.2 3 3.8 0.2 4.2 3 3.6 0.3 4.2 2.6 241 2 240 165 3 0.1 3.3 2.6 05/15/2006 04:00:00 3.7 0.5 4.9 2.3 3.9 0.6 4.9 2.6 3.7 0.6 5.3 2.6 233 9 221 165 3 0.1 3.3 2.3 05/15/2006 04:10:00 4.6 0.5 5.7 3.4 4.8 0.5 5.7 3.4 4.7 0.6 6.1 3 208 8 201 165 3.1 0.1 3.3 2.6 05/15/2006 04:20:00 4.5 0.8 5.7 2.6 4.7 0.8 5.7 2.6 4.7 1.1 6.1 2.3 201 4 198 165 3 0.1 3.3 2.3 05/15/2006 04:30:00 3.9 0.4 4.6 2.6 4.1 0.3 4.9 3 3.8 0.5 4.6 2.3 196 5 197 165 2.9 0.1 3 2.3 05/15/2006 04:40:00 4.7 0.3 5.7 3.8 4.7 0.3 5.3 3.8 4.7 0.4 5.7 3.8 190 5 193 165 2.6 0.2 3 1.8 05/15/2006 04:50:00 4.9 0.2 5.3 4.6 5 0.2 5.3 4.6 5.2 0.3 6.1 4.2 199 2 202 165 2.7 0 2.8 2.1 05/15/2006 05:00:00 4.9 0.2 5.3 4.6 5.1 0.2 5.7 4.6 5.2 0.4 6.1 3.8 200 2 202 165 2.7 0 2.8 2.3 05/15/2006 05:10:00 3.8 0.5 5.3 2.6 4 0.5 5.3 2.6 3.8 0.6 4.9 2.3 210 8 208 165 2.7 0 2.8 2.3 05/15/2006 05:20:00 3.6 0.4 4.6 2.6 3.6 0.4 4.6 3 3.7 0.5 4.6 2.6 201 10 195 165 2.9 0.2 3.3 2.1 05/15/2006 05:30:00 3.9 0.3 4.6 3 4 0.2 4.6 3 4 0.4 4.6 2.6 196 5 194 165 3.2 0 3.3 2.6 05/15/2006 05:40:00 3.5 0.2 4.2 3 3.6 0.2 4.2 3 3.5 0.3 4.2 2.6 204 3 204 165 3.4 0.1 3.5 3 05/15/2006 05:50:00 3.6 0.3 4.2 3 3.7 0.3 4.2 3 3.6 0.3 4.2 3 202 3 204 165 3.6 0.1 3.8 3.3 05/15/2006 06:00:00 3 0.5 3.8 1.9 3.1 0.5 3.8 2.3 3.1 0.5 4.2 2.3 197 1 196 165 3.8 0 4 3.3 05/15/2006 06:10:00 3.2 0.4 4.2 2.3 3.2 0.4 3.8 2.3 3.2 0.5 3.8 2.3 196 5 185 165 4 0 4.3 3.5 05/15/2006 06:20:00 3.3 0.4 4.2 2.3 3.3 0.4 4.2 2.3 3.3 0.4 4.2 2.3 183 6 184 165 4.1 0.2 4.8 3.5 05/15/2006 06:30:00 3.6 0.5 4.9 2.3 3.4 0.5 4.9 2.3 3.6 0.4 4.6 3 178 6 183 165 4.4 0 4.5 3.8 05/15/2006 06:40:00 3.8 0.5 4.9 2.6 3.6 0.4 4.6 2.3 3.8 0.4 4.9 2.6 179 8 185 165 4.1 0.1 4.5 3.8 05/15/2006 06:50:00 4 0.5 4.9 2.6 3.7 0.5 4.6 2.3 3.9 0.5 4.9 2.3 183 4 182 165 3.9 0.1 4.3 3.5 05/15/2006 07:00:00 4.2 0.5 5.7 3 3.9 0.5 5.7 2.6 4.1 0.5 5.3 3 172 10 162 165 4.1 0.1 4.5 3.5 05/15/2006 07:10:00 4.3 0.5 5.3 3.4 4.1 0.4 4.9 3 4.3 0.5 5.3 3 169 6 170 165 4.5 0.1 4.8 4 05/15/2006 07:20:00 2.9 0.6 4.2 1.1 2.9 0.5 4.2 1.1 3.1 0.5 4.6 1.9 170 9 165 165 4.9 0.2 5.2 4 05/15/2006 07:30:00 3.1 0.5 4.2 1.9 3 0.4 4.2 1.9 3.3 0.5 4.6 2.3 171 8 165 165 5.1 0 5.2 4.8 05/15/2006 07:40:00 3.2 0.4 4.2 1.5 2.9 0.4 3.8 0.7 3.3 0.4 4.2 2.3 168 9 173 165 5 0 5.2 4.8 05/15/2006 07:50:00 3.3 0.4 4.9 2.3 3.1 0.5 4.9 1.9 3.4 0.5 5.3 2.3 158 6 165 165 5.3 0 5.7 5 05/15/2006 08:00:00 3.7 0.4 4.9 3 3.5 0.4 4.6 2.6 3.7 0.4 4.9 2.6 161 7 160 165 5.4 0.1 5.7 5 05/15/2006 08:10:00 3.5 0.5 5.3 2.6 3.4 0.5 4.9 2.6 3.6 0.5 4.9 2.6 163 7 178 165 5.6 0 6 5.5 05/15/2006 08:20:00 3.3 0.6 4.9 1.9 3.2 0.6 4.9 1.9 3.4 0.6 4.6 2.3 159 9 156 165 6.1 0.2 6.2 5.2 05/15/2006 08:30:00 4.1 0.6 5.7 2.6 4 0.6 5.3 2.3 4.3 0.6 5.7 2.6 159 9 160 165 6.2 0 6.2 6 05/15/2006 08:40:00 4.5 0.4 6.1 3.8 4.4 0.4 6.1 3.4 4.6 0.4 6.1 3 163 5 165 165 6 0.1 6.2 5.7 05/15/2006 08:50:00 3.8 0.6 5.3 2.3 3.7 0.6 4.9 2.3 3.8 0.7 5.7 2.3 159 9 155 165 6.4 0.3 7 5.7 05/15/2006 09:00:00 3.8 0.7 5.3 1.5 3.8 0.7 5.3 1.5 3.8 0.7 5.7 1.9 161 12 156 165 6.8 0 7 6.7 05/15/2006 09:10:00 4.2 0.7 6.1 2.3 4.1 0.7 6.5 2.3 4.3 0.7 6.1 2.3 162 10 157 165 6.9 0.1 7.5 6.7 05/15/2006 09:20:00 5.1 0.7 7.2 3 4.9 0.7 7.2 2.6 5.1 0.7 6.8 3 171 9 165 165 7 0.1 7.5 6.7 05/15/2006 09:30:00 5.4 0.7 7.2 3.4 5.2 0.7 7.2 3.4 5.3 0.7 7.2 3.4 162 17 176 165 7.1 0 7.3 7 05/15/2006 09:40:00 5.8 0.6 7.6 3.8 5.7 0.6 7.2 3.8 6.1 0.6 8 4.2 163 12 173 165 7.5 0 7.8 7.3 05/15/2006 09:50:00 6.1 0.5 7.6 4.6 6 0.5 8 4.2 6.3 0.5 8 4.9 166 7 183 165 7.3 0.2 7.8 7 05/15/2006 10:00:00 6.3 0.6 8 3.8 6.1 0.6 8 3.8 6.5 0.7 8.4 4.6 167 7 172 165 7.6 0.1 8 7.3 05/15/2006 10:10:00 6.3 0.8 8.8 4.6 6.2 0.8 8.8 4.6 6.5 0.9 8.8 4.6 169 9 165 165 7.8 0 8.3 7.5 05/15/2006 10:20:00 6.3 0.7 8.4 4.6 6.3 0.7 8 4.2 6.6 0.7 8.4 4.6 169 6 165 165 7.5 0.1 7.8 7.3 05/15/2006 10:30:00 6.1 0.8 8 4.6 6 0.8 8 4.2 6.2 0.7 8 4.6 170 13 165 165 8.2 0.3 9 7.5 05/15/2006 10:40:00 6.2 0.7 8.4 4.6 6.2 0.8 8.4 4.2 6.4 0.8 8.8 4.6 164 13 225 165 8.1 0.2 8.8 7.5 05/15/2006 10:50:00 6.5 0.7 8.8 4.2 6.4 0.8 8.8 4.2 6.6 0.7 8.4 4.6 168 16 164 165 8.3 0.2 9 8 05/15/2006 11:00:00 6.3 0.7 8 4.6 6.1 0.7 8 4.6 6.5 0.8 8.4 4.6 170 11 171 165 7.8 0.1 8.5 7.5 05/15/2006 11:10:00 6.6 0.6 8.4 4.9 6.5 0.7 8.4 4.9 6.7 0.6 8.4 4.9 167 15 173 165 8.1 0.4 8.8 7.5 05/15/2006 11:20:00 6.1 0.8 8 4.2 6 0.8 8 3.8 6.1 0.9 8 3.8 163 12 151 165 8.3 0.4 9 7.8 05/15/2006 11:30:00 6.4 0.8 8.4 4.2 6.4 0.8 8.4 4.2 6.5 0.7 8.4 4.6 156 12 165 165 8.5 0.1 9 8.3 05/15/2006 11:40:00 6.3 0.6 8 4.6 6.3 0.7 8 4.6 6.5 0.7 8.8 4.6 151 9 165 165 8.6 0.2 9 8.3 05/15/2006 11:50:00 6.3 0.5 8.4 4.9 6.2 0.6 8.4 4.9 6.4 0.5 8.4 5.3 149 5 154 165 8.7 0.1 9 8.5 05/15/2006 12:00:00 6.2 0.6 8 4.2 6.1 0.6 8 3.8 6.4 0.6 8.4 4.9 149 7 147 165 8.7 0.2 9.3 8.3 05/15/2006 12:10:00 6.1 0.6 7.6 4.6 6.1 0.6 7.6 4.6 6.2 0.6 8 4.2 146 9 135 165 8.5 0.2 9 8.3 05/15/2006 12:20:00 5.9 0.5 7.6 4.6 5.9 0.5 7.2 4.6 6.1 0.5 8 5.3 148 6 151 165 8.7 0.1 9 8.5 05/15/2006 12:30:00 5.9 0.6 7.2 4.6 5.8 0.6 7.6 4.2 6 0.6 7.2 4.6 149 7 154 165 8.7 0.2 9 8.3 05/15/2006 12:40:00 5.4 0.6 6.8 3.8 5.3 0.6 7.6 3.4 5.4 0.6 7.2 3.8 146 9 156 165 8.8 0 9 8.5 05/15/2006 12:50:00 5.2 0.6 7.2 3.8 5.1 0.6 7.2 3.8 5.3 0.6 7.2 3.4 143 10 132 165 8.9 0.2 9.6 8.5 05/15/2006 13:00:00 5.4 0.6 7.6 4.2 5.3 0.7 7.6 3.8 5.4 0.6 6.8 4.2 140 8 151 165 8.5 0.1 8.8 8.3 05/15/2006 13:10:00 5 0.6 6.8 3.4 5 0.6 7.2 3.4 5.2 0.6 7.6 3.8 140 8 142 165 8.7 0.2 9.6 8.3 05/15/2006 13:20:00 5.2 0.6 7.6 3.8 5.2 0.7 7.6 3.8 5.3 0.7 7.6 3.8 141 9 130 165 8.7 0.2 9.3 8.3 05/15/2006 13:30:00 5.5 0.6 7.6 4.2 5.5 0.7 7.2 3.8 5.6 0.7 8 4.2 140 9 142 165 9 0.1 9.6 8.5 05/15/2006 13:40:00 5.6 0.6 7.6 3.8 5.6 0.6 7.2 3.4 5.8 0.8 7.6 4.2 143 10 143 165 8.9 0.2 9.3 8.3 05/15/2006 13:50:00 5.2 0.6 6.8 3.8 5.2 0.6 6.5 3.8 5.4 0.6 7.2 3.8 145 9 147 165 8.4 0 8.8 8.3 05/15/2006 14:00:00 5.3 0.7 7.2 3.4 5.3 0.7 7.2 3.8 5.3 0.7 7.2 3.4 141 10 145 165 8.7 0.2 9.3 8.5 05/15/2006 14:10:00 5.5 0.7 7.2 3.8 5.4 0.7 7.2 3.8 5.5 0.8 7.2 3.4 143 9 152 165 8.6 0.3 9.6 8.3 05/15/2006 14:20:00 5.6 0.6 7.6 4.6 5.6 0.7 7.6 4.2 5.8 0.7 7.6 4.2 142 7 138 165 9 0.2 9.8 8.5 05/15/2006 14:30:00 5.6 0.6 7.2 4.2 5.6 0.6 7.2 4.2 5.7 0.6 7.6 4.6 140 8 141 165 8.7 0 9 8.5 05/15/2006 14:40:00 5.8 0.5 8 4.2 5.8 0.6 8 4.2 5.8 0.5 7.6 4.6 142 7 140 165 9 0.2 9.6 8.8 05/15/2006 14:50:00 6.2 0.5 7.6 4.6 6.2 0.6 7.6 4.6 6.2 0.7 7.6 4.6 142 9 142 165 9.2 0.2 9.8 8.8 05/15/2006 15:00:00 6.1 0.5 7.6 4.9 6.1 0.5 7.2 4.9 6.1 0.5 7.2 4.9 141 8 122 165 9.1 0.3 10.1 8.5 05/15/2006 15:10:00 6.3 0.6 8 4.2 6.3 0.6 8 4.6 6.5 0.6 8 4.9 147 10 162 165 9.4 0.2 10.3 8.8 05/15/2006 15:20:00 6.6 0.6 8 4.9 6.6 0.6 8 5.3 6.8 0.6 8.4 5.3 152 6 153 165 9.4 0.2 9.8 9 05/15/2006 15:30:00 7.3 0.6 9.5 5.7 7.3 0.6 9.1 5.7 7.5 0.6 9.1 5.7 156 7 155 165 9.4 0.1 9.6 9 05/15/2006 15:40:00 7.5 0.5 9.1 6.1 7.3 0.6 9.1 5.7 7.6 0.5 9.1 6.1 161 8 143 165 8.8 0.3 9.6 8 05/15/2006 15:50:00 7.3 0.6 8.8 4.9 7.2 0.6 8.8 5.3 7.5 0.6 9.1 5.7 156 8 147 165 8.3 0.5 9 7.5 05/15/2006 16:00:00 7 0.8 8.8 4.9 6.9 0.8 8.8 4.9 7.1 0.8 9.1 4.9 164 7 157 165 9.1 0.1 9.8 8.8 05/15/2006 16:10:00 7.2 0.8 9.5 4.9 7.1 0.8 9.5 4.9 7.4 0.9 9.9 5.3 174 9 181 165 8.8 0.1 9.3 8.5 05/15/2006 16:20:00 6.7 0.7 8.4 4.9 6.7 0.7 8.4 4.9 7 0.8 9.5 4.9 178 13 183 165 8.5 0.1 9 8.3 05/15/2006 16:30:00 7 0.8 8.8 4.6 7 0.8 9.1 4.9 7 0.9 9.5 4.9 182 9 189 165 9.3 0.1 9.8 8.5 05/15/2006 16:40:00 5.1 1 7.2 2.6 5.3 1 7.6 3 5.3 0.9 7.2 3 194 15 187 165 9.4 0 9.8 9 05/15/2006 16:50:00 6.8 1.1 9.1 3.8 6.8 1.1 9.1 3.8 7 1.3 9.5 3.4 179 11 179 165 9 0.3 9.8 8.5 05/15/2006 17:00:00 6.7 0.9 9.1 4.6 6.6 0.9 9.1 4.6 6.7 1.1 9.5 4.2 179 9 189 165 8.9 0 9 8.5 05/15/2006 17:10:00 6.2 0.9 9.5 3.8 6.2 0.9 9.1 3.8 6.4 1 8.4 3.8 181 11 183 165 8.7 0 9 8.5 05/15/2006 17:20:00 6.3 0.7 8 4.6 6.2 0.7 7.6 4.6 6.5 0.7 8.4 4.6 177 9 175 165 8.6 0.1 8.8 8.5 05/15/2006 17:30:00 6 0.7 8 3.8 5.9 0.7 7.6 3.8 6.2 0.7 8 4.2 175 8 184 165 8.5 0 8.8 8.5 05/15/2006 17:40:00 6.5 0.7 8 4.6 6.3 0.6 7.6 4.6 6.6 0.7 8 4.9 172 7 165 165 8.3 0 8.5 8.3 05/15/2006 17:50:00 6.6 0.7 9.1 4.6 6.5 0.7 8.8 4.6 6.9 0.8 9.1 4.2 179 9 177 165 8.1 0 8.5 8 05/15/2006 18:00:00 5.8 0.8 8.4 3.8 5.7 0.8 8.8 3.8 6 0.7 8.4 4.6 177 9 174 165 8.2 0 8.5 8 05/15/2006 18:10:00 5.3 0.8 8 3.4 5.2 0.8 8 3.8 5.4 0.8 8.4 3.8 179 9 176 165 8.1 0 8.3 8 05/15/2006 18:20:00 5.9 0.6 7.6 4.6 5.8 0.6 7.2 4.2 6 0.5 7.2 4.6 176 8 164 165 8 0.1 8.5 7.8 05/15/2006 18:30:00 5.7 0.6 7.6 4.2 5.5 0.6 7.2 3.8 5.9 0.7 7.6 3.8 173 7 181 165 7.8 0 8.3 7.5 05/15/2006 18:40:00 5.9 0.8 8 3.8 5.7 0.7 7.6 3.8 5.9 0.9 8.4 3.8 173 7 172 165 7.6 0 7.8 7.5 05/15/2006 18:50:00 4.9 0.8 6.8 2.6 4.8 0.8 6.8 2.6 5 0.8 7.6 3 176 9 178 165 7.7 0 8.3 7.5 05/15/2006 19:00:00 4.3 0.6 6.5 3 4.3 0.7 6.5 3 4.4 0.7 6.5 2.6 183 11 184 165 7.8 0 7.8 7.5 05/15/2006 19:10:00 3.6 0.5 4.9 2.3 3.6 0.5 4.9 2.6 3.7 0.5 4.9 2.3 182 11 200 165 7.6 0 7.8 7.3 05/15/2006 19:20:00 3.1 0.8 4.9 1.5 3.2 0.8 4.9 1.5 3.2 1 4.9 1.1 204 12 197 165 7.6 0 7.8 7.5 05/15/2006 19:30:00 3 1.2 4.9 0.4 3.2 1.1 5.3 0.7 2.9 1.2 4.9 0.4 265 23 276 165 8 0.1 8.3 7.3 05/15/2006 19:40:00 3.5 0.4 4.6 2.6 3.6 0.4 4.6 2.6 2.8 0.5 4.2 1.5 297 6 303 165 8 0.1 8.3 7.3 05/15/2006 19:50:00 3.8 0.4 4.6 2.6 3.9 0.4 4.9 2.6 3 0.5 4.2 1.9 299 5 293 165 7.8 0 8 7.5 05/15/2006 20:00:00 3.7 0.5 4.6 2.6 3.8 0.5 4.9 2.6 2.9 0.4 4.2 1.9 300 6 300 165 7.6 0.1 8 7.3 05/15/2006 20:10:00 4.3 0.4 4.9 3.4 4.3 0.4 5.3 3.4 3.2 0.4 4.2 2.3 301 4 300 165 7.1 0.1 7.5 6.5 05/15/2006 20:20:00 4.7 0.4 5.7 3.8 4.8 0.4 5.7 3.8 3.8 0.6 5.3 2.3 298 6 298 165 6.5 0.2 7 6.2 05/15/2006 20:30:00 4.9 0.3 5.7 3.8 4.9 0.3 5.7 4.2 3.5 0.4 4.9 2.3 300 4 296 165 6.2 0.1 6.2 5.7 05/15/2006 20:40:00 4.6 0.5 5.7 3.4 4.6 0.5 5.7 3.4 3.7 0.6 5.3 2.3 302 8 306 165 6 0.1 6.2 5.5 05/15/2006 20:50:00 4.6 0.6 6.1 3.4 4.7 0.5 6.1 3.4 4 0.5 5.3 2.6 309 7 307 165 5.5 0.1 6 5.2 05/15/2006 21:00:00 4.7 0.7 6.1 3 4.7 0.7 6.1 3 4 0.6 5.7 2.6 310 5 318 165 5.2 0.2 5.7 4.8 05/15/2006 21:10:00 4.7 0.6 6.1 3.4 4.8 0.6 6.1 3.4 3.5 0.6 5.7 1.9 299 6 310 165 5.1 0.2 5.2 4.8 05/15/2006 21:20:00 4.4 0.5 5.7 3.4 4.5 0.5 6.1 3.4 3.4 0.6 4.9 2.3 297 4 291 165 4.9 0.2 5.2 4.5 05/15/2006 21:30:00 3.6 0.5 4.9 1.9 3.8 0.6 4.9 2.3 2.9 0.6 4.9 1.5 296 5 292 165 5 0.1 5.2 4.5 05/15/2006 21:40:00 3.5 1 4.9 1.5 3.7 0.9 5.3 1.9 3.2 0.9 4.9 1.1 293 5 284 165 4.9 0 5.2 4.5 05/15/2006 21:50:00 1.4 0.4 2.6 0.4 1.7 0.5 2.6 0.4 1.4 0.4 2.3 0.4 293 6 283 165 5 0 5.2 4.5 05/15/2006 22:00:00 2.8 0.9 4.9 1.1 3.1 0.8 4.9 1.1 3 0.9 4.9 1.1 280 6 289 165 4.9 0.1 5.2 4.5 05/15/2006 22:10:00 4.4 0.5 6.1 3.4 4.7 0.5 6.8 3.4 4.2 0.5 5.7 2.6 286 5 294 165 4.5 0 4.8 4.3 05/15/2006 22:20:00 5.9 0.6 7.2 4.6 6.1 0.6 7.2 4.6 5 0.7 6.8 3 292 4 294 165 4.3 0 4.5 4.3 05/15/2006 22:30:00 5 0.6 6.5 3.4 5 0.6 6.5 3.8 4.3 0.7 6.1 2.3 292 5 296 165 4.3 0 4.5 4.3 05/15/2006 22:40:00 5.2 0.6 6.5 3.4 5.3 0.6 6.8 3.8 4.2 0.8 6.5 2.6 294 6 287 165 4.2 0 4.5 4 05/15/2006 22:50:00 5.7 0.5 7.2 4.2 5.8 0.5 7.2 4.6 4.5 0.7 6.5 3 295 4 292 165 4.2 0 4.5 4 05/15/2006 23:00:00 5.5 0.5 6.8 3.4 5.6 0.5 6.8 3.8 4.3 0.6 6.1 2.6 298 5 293 165 4.1 0 4.5 3.8 05/15/2006 23:10:00 5.8 0.5 6.8 4.6 6 0.5 6.8 4.6 4.5 0.7 6.5 3 297 5 297 165 4 0 4.3 3.5 05/15/2006 23:20:00 5.4 0.6 6.8 3.8 5.5 0.6 7.2 3.8 4.3 0.6 6.1 3 299 6 295 165 3.9 0 4 3.5 05/15/2006 23:30:00 5.7 0.7 7.2 3.8 5.7 0.7 7.2 4.2 4.6 0.7 6.1 3 306 7 295 165 3.8 0 4 3.5 05/15/2006 23:40:00 4.7 0.5 6.5 3.4 4.8 0.5 6.5 3.4 4.3 0.6 5.7 2.6 310 6 310 165 3.7 0 3.8 3.5 05/15/2006 23:50:00 4.7 0.5 5.7 3.4 4.9 0.5 6.1 3.8 4.2 0.5 5.7 3 305 8 304 165 3.6 0 3.8 3.3 05/16/2006 00:00:00 5.5 0.7 6.8 3.8 5.6 0.6 6.8 4.2 4.2 0.6 5.7 2.6 302 5 297 165 3.6 0 3.8 3.3 05/16/2006 00:10:00 5.5 0.7 6.8 3.8 5.7 0.6 6.8 3.8 4.4 0.6 6.5 2.6 300 6 289 165 3.6 0 3.8 3.3 05/16/2006 00:20:00 5.4 0.5 6.5 4.2 5.5 0.5 6.8 4.2 4 0.6 5.3 2.6 301 4 297 165 3.5 0.1 3.8 3 05/16/2006 00:30:00 5.1 0.5 6.5 3.8 5.2 0.5 6.5 3.8 3.9 0.5 5.3 2.6 300 4 300 165 3.5 0.1 3.5 3 05/16/2006 00:40:00 5 0.6 6.5 3.8 5.2 0.6 6.5 3.8 4 0.6 5.7 2.6 298 5 302 165 3.4 0.1 3.5 3 05/16/2006 00:50:00 4.8 0.6 6.5 3.8 4.9 0.6 6.1 3.8 4.2 0.8 6.1 2.6 295 4 300 165 3.5 0.1 3.5 2.8 05/16/2006 01:00:00 5.4 0.6 6.8 4.2 5.5 0.6 6.8 4.2 4.8 0.8 6.5 2.6 291 4 290 165 3.4 0.1 3.5 2.8 05/16/2006 01:10:00 5.1 0.7 6.8 3.8 5.2 0.6 6.8 3.8 4.5 0.7 6.1 2.6 293 3 292 165 3.3 0 3.5 2.8 05/16/2006 01:20:00 4.9 0.3 5.7 4.2 5 0.3 6.1 4.2 3.8 0.5 5.3 2.6 297 4 299 165 3.3 0 3.5 2.8 05/16/2006 01:30:00 4.4 0.3 5.3 3.8 4.6 0.3 5.3 3.8 3.8 0.4 4.6 2.6 301 6 307 165 3.3 0 3.5 2.8 05/16/2006 01:40:00 3.9 0.3 4.6 3.4 4.1 0.3 4.9 3.4 3.5 0.4 4.6 2.6 307 2 306 165 3.3 0 3.5 3 05/16/2006 01:50:00 3.6 0.3 4.2 2.6 3.7 0.3 4.2 3 3.6 0.4 4.6 2.6 311 2 312 165 3.3 0 3.5 3 05/16/2006 02:00:00 2.9 0.3 3.8 2.3 3.1 0.3 3.8 2.3 2.8 0.4 3.8 1.9 304 8 295 165 3.4 0 3.5 3.3 05/16/2006 02:10:00 2.9 0.3 3.8 1.9 3.2 0.3 3.8 2.3 3.3 0.4 4.6 2.3 288 5 279 165 3.1 0.1 3.5 2.8 05/16/2006 02:20:00 3.1 0.3 3.8 2.3 3.3 0.4 4.2 2.6 3.4 0.3 4.2 2.6 278 6 277 165 3.1 0 3.3 2.8 05/16/2006 02:30:00 2.9 0.4 3.8 1.9 3.1 0.4 3.8 1.9 3.1 0.3 3.8 2.3 275 3 271 165 3.2 0 3.5 2.8 05/16/2006 02:40:00 2.5 0.3 3 1.5 2.6 0.3 3.4 1.9 2.8 0.2 3.4 2.3 275 4 273 165 3.3 0 3.5 3 05/16/2006 02:50:00 2.4 0.4 3 1.5 2.7 0.3 3 2.3 2.8 0.2 3.4 2.3 250 8 248 165 3.3 0 3.5 3 05/16/2006 03:00:00 2.1 0.5 3 0.4 2.1 0.6 3 0.4 2.6 0.3 3 1.9 233 7 243 165 3.2 0.1 3.8 2.8 05/16/2006 03:10:00 1.1 0.3 1.9 0.4 1.1 0.3 1.9 0.4 1.8 0.2 2.6 1.1 236 8 225 165 3.2 0 3.5 2.8 05/16/2006 03:20:00 0.8 0.3 1.5 0.4 0.8 0.3 1.5 0.4 1.5 0.2 1.9 1.1 239 5 236 165 3.1 0 3.3 2.8 05/16/2006 03:30:00 0.8 0.3 1.9 0.4 0.7 0.4 1.9 0.4 1.4 0.2 1.9 0.7 234 9 216 165 3 0.1 3.3 2.6 05/16/2006 03:40:00 0.8 0.3 1.5 0.4 0.8 0.3 1.5 0.4 1.3 0.2 1.9 0.7 226 6 229 165 3.2 0.1 3.5 2.6 05/16/2006 03:50:00 1 0.4 1.9 0.4 1 0.4 1.5 0.4 1.6 0.3 2.3 1.1 201 14 190 165 3.1 0.1 3.5 3 05/16/2006 04:00:00 0.9 0.3 1.5 0.4 0.8 0.4 1.5 0.4 1.3 0.4 1.9 0.4 195 11 190 165 3 0 3.5 2.8 05/16/2006 04:10:00 0.4 0.2 1.1 0.4 0.4 0.1 1.1 0.4 1.1 0.2 1.9 0.7 215 9 207 165 3.2 0.1 3.5 2.8 05/16/2006 04:20:00 0.7 0.3 1.5 0.4 0.5 0.3 1.5 0.4 1.2 0.2 1.5 0.7 237 7 233 165 3.5 0 3.8 3.3 05/16/2006 04:30:00 0.4 0.1 0.7 0.4 0.4 0 0.4 0.4 0.7 0.4 1.5 0.4 250 0 250 165 3.6 0 3.8 3.5 05/16/2006 04:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.5 0.2 1.1 0.4 250 0 165 165 3.3 0 3.5 3 05/16/2006 04:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.8 0.2 1.1 0.4 249 0 165 165 3.2 0 3.5 3 05/16/2006 05:00:00 0.4 0 0.7 0.4 0.4 0 0.4 0.4 0.8 0.3 1.5 0.4 249 1 237 165 3.3 0 3.5 3 05/16/2006 05:10:00 0.4 0.1 1.1 0.4 0.4 0 0.7 0.4 0.8 0.2 1.5 0.4 240 13 236 165 3.2 0 3.5 3 05/16/2006 05:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0.2 1.1 0.4 277 16 165 165 3.6 0.1 4 3.3 05/16/2006 05:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0.1 0.7 0.4 241 0 165 165 4.1 0.1 4.5 3.8 05/16/2006 05:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 241 0 165 165 4.6 0.2 5 4.3 05/16/2006 05:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.7 0.4 247 12 165 165 5.1 0.2 5.5 4.5 05/16/2006 06:00:00 0.6 0.4 1.5 0.4 0.4 0.2 1.1 0.4 0.9 0.4 1.5 0.4 309 41 4 165 5 0.1 5.5 4.5 05/16/2006 06:10:00 1.7 0.3 2.3 1.1 1.4 0.4 1.9 0.4 1.7 0.3 2.3 0.7 13 6 15 165 5.1 0.2 5.5 4.5 05/16/2006 06:20:00 2.1 0.2 2.6 1.9 2.1 0.2 2.6 1.5 2.2 0.2 2.6 1.9 23 5 29 165 5.2 0.1 5.5 4.8 05/16/2006 06:30:00 2.1 0.2 2.6 1.5 2.2 0.2 2.6 1.5 2.1 0.3 2.6 1.5 35 5 29 165 4.9 0 5.5 4.8 05/16/2006 06:40:00 1.7 0.4 2.6 0.7 1.8 0.4 2.6 0.7 1.6 0.4 2.3 0.7 46 9 35 165 5.1 0.1 5.5 4.8 05/16/2006 06:50:00 0.7 0.4 1.5 0.4 0.7 0.4 1.5 0.4 0.6 0.4 1.5 0.4 32 2 32 165 6.1 0.4 7 5.2 05/16/2006 07:00:00 0.5 0.3 1.5 0.4 0.5 0.3 1.9 0.4 0.4 0.3 1.5 0.4 10 58 117 165 6.1 0.6 7 5.2 05/16/2006 07:10:00 1.4 1 4.2 0.4 1.4 1.1 4.2 0.4 1.3 1 4.2 0.4 239 28 230 165 4.8 0.3 5.5 4.3 05/16/2006 07:20:00 2.8 0.6 4.2 1.5 2.9 0.6 4.2 1.1 2.5 0.7 4.2 0.7 284 12 286 165 4.9 0.4 5.5 4 05/16/2006 07:30:00 2.4 0.4 3.4 1.5 2.4 0.4 3.4 1.5 1.9 0.4 3.4 0.7 299 8 310 165 5.5 0.4 6.2 5 05/16/2006 07:40:00 3.1 0.5 4.2 1.5 3.1 0.5 4.2 1.5 2.5 0.6 4.2 1.1 293 8 291 165 6 0.2 6.2 5.5 05/16/2006 07:50:00 3.4 0.4 4.2 2.3 3.4 0.4 4.2 2.3 2.8 0.5 4.2 1.5 294 7 290 165 5.7 0 6 5.5 05/16/2006 08:00:00 3 0.5 4.6 1.5 3 0.5 4.2 1.9 2.3 0.6 3.8 0.7 299 8 305 165 6.2 0.3 7 5.7 05/16/2006 08:10:00 2.9 0.7 4.2 1.5 2.9 0.7 4.2 1.5 2.5 0.7 4.2 0.4 308 10 307 165 6.6 0 7 6.2 05/16/2006 08:20:00 3.4 0.7 4.9 1.1 3.4 0.8 4.9 1.1 3.1 0.7 4.9 1.1 320 11 313 165 6.7 0 7 6.5 05/16/2006 08:30:00 4 0.6 5.7 3 4 0.6 5.7 2.6 3.7 0.5 5.3 2.3 313 8 319 165 6.7 0.1 7.3 6.2 05/16/2006 08:40:00 4.6 0.5 6.1 3 4.6 0.5 6.1 3.4 4.2 0.7 5.7 2.6 313 8 309 165 5.9 0.2 6.2 5.7 05/16/2006 08:50:00 4.8 0.5 6.1 3.8 4.8 0.5 6.1 3.4 4.4 0.6 6.1 3 310 8 326 165 6 0.1 6.2 5.7 05/16/2006 09:00:00 4.8 0.6 6.8 3.4 4.8 0.5 6.1 3.4 4.3 0.7 6.5 2.6 310 8 325 165 5.9 0.1 6.2 5.7 05/16/2006 09:10:00 4.9 0.7 6.5 2.6 5 0.6 6.5 3 4.5 0.9 6.5 2.3 309 8 307 165 5.9 0.1 6.7 5.7 05/16/2006 09:20:00 4.3 0.7 5.7 2.6 4.3 0.7 5.7 2.6 3.6 0.8 5.7 1.9 309 9 313 165 6.1 0.2 7 5.7 05/16/2006 09:30:00 3.5 1 6.8 0.4 3.5 1.1 6.8 0.4 2.9 0.9 5.3 0.4 304 21 281 165 6.3 0.4 7.3 5.7 05/16/2006 09:40:00 2.9 0.7 5.7 1.9 2.9 0.7 5.7 1.9 2.5 0.6 4.6 1.1 310 13 293 165 6.5 0.3 7.5 6 05/16/2006 09:50:00 1.7 0.7 3.4 0.4 1.7 0.7 3.4 0.4 1.4 0.6 3 0.4 303 58 308 165 8 0.5 9.3 7 05/16/2006 10:00:00 1.6 0.7 3.4 0.4 1.6 0.7 3.8 0.4 1.3 0.8 3.4 0.4 321 94 233 165 9 0.2 9.3 8.5 05/16/2006 10:10:00 1.4 0.9 3.4 0.4 1.3 0.8 3.4 0.4 1.4 0.8 3.4 0.4 176 66 164 165 8 0.1 8.5 7.8 05/16/2006 10:20:00 1.4 0.7 4.6 0.4 1.4 0.7 4.6 0.4 1 0.6 2.6 0.4 194 90 241 165 8.3 0.3 8.5 7.8 05/16/2006 10:30:00 2 0.8 4.2 0.4 2 0.7 4.6 0.4 2.1 0.7 4.6 0.4 163 38 150 165 8.3 0.2 8.8 8 05/16/2006 10:40:00 2.5 0.8 4.6 0.7 2.5 0.8 4.9 0.7 2.7 1 4.9 0.4 135 35 167 165 7.5 0.6 8.5 6.7 05/16/2006 10:50:00 1.8 0.9 4.9 0.4 1.7 1 4.6 0.4 2 1 4.6 0.4 160 66 167 165 8.5 0.1 8.8 8 05/16/2006 11:00:00 2.5 1 4.6 0.4 2.5 1 4.6 0.4 2.5 1 4.9 0.4 133 26 132 165 7.4 0.3 8.3 7 05/16/2006 11:10:00 3.1 0.8 5.3 1.1 3 0.8 5.3 1.1 3.3 0.7 5.3 1.5 165 15 159 165 7.6 0.4 8.3 7.3 05/16/2006 11:20:00 3.8 0.8 6.1 1.9 3.9 0.8 6.5 1.5 4.1 0.7 6.1 2.3 150 16 124 165 7.5 0.1 7.8 7.3 05/16/2006 11:30:00 3.8 0.7 6.1 2.3 3.7 0.8 6.1 2.3 3.8 0.7 5.7 1.9 152 13 159 165 7.8 0.3 8.5 7.3 05/16/2006 11:40:00 3.6 1.1 6.1 0.7 3.5 1.1 6.1 0.7 3.7 1 6.1 1.1 149 22 143 165 7.6 0.2 8.3 7.3 05/16/2006 11:50:00 4.9 1 7.6 2.6 5 0.9 7.2 2.6 5.1 0.9 7.6 2.6 144 11 132 165 7.4 0.5 8.8 6.7 05/16/2006 12:00:00 5 0.9 6.8 2.6 5 0.9 6.8 3 5.1 0.8 6.8 3 146 12 148 165 7.3 0.3 8.3 6.7 05/16/2006 12:10:00 4.7 1 7.6 2.3 4.6 1 7.2 1.9 4.9 1 6.8 2.6 144 12 122 165 7.3 0.1 7.8 7 05/16/2006 12:20:00 4.7 0.8 6.5 2.6 4.6 0.8 6.5 2.6 4.9 0.8 6.8 2.6 150 12 136 165 7.4 0 7.8 7.3 05/16/2006 12:30:00 4 1.3 6.8 1.5 3.9 1.3 7.2 1.5 4.2 1.3 6.8 1.5 145 13 140 165 7.4 0.2 8.3 7 05/16/2006 12:40:00 5.2 0.6 6.8 3.8 5.2 0.6 6.8 3.8 5.3 0.7 6.8 3.4 151 8 148 165 7.6 0.1 8.3 7.3 05/16/2006 12:50:00 4.2 0.9 6.5 1.9 4.1 0.9 6.5 2.3 4.2 0.9 6.5 2.6 147 12 139 165 7.5 0.3 8 7 05/16/2006 13:00:00 3.9 0.8 6.1 1.9 3.9 0.8 5.7 2.3 4.2 0.8 6.5 2.3 145 15 130 165 7.7 0 8 7.5 05/16/2006 13:10:00 4.5 0.9 6.8 1.1 4.5 0.9 6.8 1.5 4.6 1 7.2 1.9 146 14 148 165 7.9 0.2 8.3 7.3 05/16/2006 13:20:00 4.8 0.7 6.5 3 4.8 0.7 6.5 3 4.9 0.7 6.8 3 146 12 145 165 7.3 0.1 7.8 7 05/16/2006 13:30:00 4.8 0.7 6.8 3 4.7 0.8 6.5 2.6 4.8 0.8 6.8 2.6 156 13 165 165 7.2 0.2 8 6.7 05/16/2006 13:40:00 4.6 0.8 6.5 2.6 4.6 0.8 6.5 2.6 4.6 0.8 6.5 2.3 147 14 139 165 7.8 0.2 8.3 7.3 05/16/2006 13:50:00 4.3 0.8 6.5 2.6 4.3 0.8 6.5 2.6 4.3 0.9 6.8 1.9 149 14 148 165 8 0.3 8.5 7.3 05/16/2006 14:00:00 5 0.7 6.5 2.6 5 0.8 6.8 2.3 5.1 0.7 6.8 2.6 150 12 140 165 8 0.4 8.8 7.3 05/16/2006 14:10:00 4.5 0.9 6.5 2.3 4.4 1 6.1 2.3 4.6 1 6.5 2.6 151 17 145 165 7.6 0.3 8.5 7.3 05/16/2006 14:20:00 4.8 0.7 6.5 3 4.8 0.7 6.5 3 4.8 0.7 6.8 3 149 12 151 165 7.7 0.1 8 7.5 05/16/2006 14:30:00 4.9 0.6 6.8 3.4 4.9 0.7 6.5 3 5.2 0.6 6.5 3.4 147 9 141 165 7.8 0 8.3 7.5 05/16/2006 14:40:00 4.9 0.5 6.5 3.4 4.9 0.5 6.1 3.4 5.1 0.6 6.5 3 144 9 146 165 7.8 0 8.3 7.5 05/16/2006 14:50:00 4.2 1 6.8 1.9 4.2 1 7.2 1.9 4.3 1 6.8 1.9 145 13 131 165 8.1 0.1 8.5 7.8 05/16/2006 15:00:00 2.7 0.6 4.6 1.1 2.7 0.5 4.6 1.5 2.8 0.7 4.9 0.7 139 17 127 165 8.2 0 8.5 8 05/16/2006 15:10:00 4.3 0.7 6.1 2.3 4.2 0.7 6.1 2.3 4.4 0.8 5.7 2.3 144 12 140 165 8.4 0.1 8.8 8 05/16/2006 15:20:00 4.1 0.7 6.1 2.6 4.2 0.8 6.1 2.6 4.3 0.7 6.1 2.6 131 12 133 165 8.5 0.1 8.8 8 05/16/2006 15:30:00 3.7 0.8 6.1 1.5 3.6 0.8 6.1 1.5 3.8 0.7 5.7 1.9 139 16 164 165 8.5 0.2 8.8 8 05/16/2006 15:40:00 3.2 1 5.3 0.7 3.2 1 5.7 0.4 3.3 1 5.7 0.7 124 23 147 165 8.7 0 9 8.5 05/16/2006 15:50:00 3.6 0.8 5.7 1.1 3.6 0.8 5.7 1.1 3.7 0.7 5.7 1.9 133 18 145 165 9 0 9.3 8.8 05/16/2006 16:00:00 4 0.6 6.1 2.3 4 0.6 5.7 2.3 4 0.6 5.7 2.6 148 14 137 165 8.3 0.2 9 8 05/16/2006 16:10:00 3.5 1 5.7 0.7 3.5 1 5.3 0.7 3.7 0.8 5.7 1.5 138 15 151 165 8.4 0.1 8.8 8 05/16/2006 16:20:00 4.1 0.8 6.1 1.5 4.2 0.8 6.1 1.9 4.2 0.8 6.1 2.3 137 17 150 165 8.3 0.1 8.8 8 05/16/2006 16:30:00 3.7 0.8 6.1 1.5 3.7 0.8 6.1 1.5 3.7 0.7 5.3 2.3 136 17 142 165 8.4 0.3 9 8 05/16/2006 16:40:00 3.3 0.6 5.3 1.9 3.3 0.7 5.3 1.9 3.3 0.7 5.3 1.9 144 13 132 165 8.5 0.1 9 8.3 05/16/2006 16:50:00 3.3 0.6 5.3 1.9 3.3 0.6 5.3 1.9 3.4 0.6 5.3 1.9 139 11 144 165 8.5 0.1 9 8.3 05/16/2006 17:00:00 3.2 0.5 4.9 2.3 3.2 0.5 4.9 2.3 3.2 0.5 5.3 1.9 134 15 122 165 8.6 0.1 9 8.5 05/16/2006 17:10:00 2.5 0.5 4.2 1.1 2.5 0.6 4.2 0.7 2.5 0.6 3.8 0.4 129 21 123 165 8.9 0.2 9.3 8.5 05/16/2006 17:20:00 1.8 0.7 3.4 0.4 1.8 0.7 3.4 0.4 2 0.7 3.4 0.4 111 41 121 165 9.4 0.3 10.1 9 05/16/2006 17:30:00 2 0.7 4.2 0.4 2 0.7 3.4 0.4 2.1 0.6 3.8 0.7 120 47 23 165 10.1 0.1 10.9 9.8 05/16/2006 17:40:00 2.2 0.9 4.9 0.4 2.2 0.9 4.6 0.4 2.2 1 6.8 0.4 63 43 41 165 9.8 0.2 10.6 9.3 05/16/2006 17:50:00 1.8 0.7 3.4 0.4 1.8 0.8 3.8 0.4 1.9 0.7 4.2 0.4 49 66 49 165 10.2 0.4 10.9 9.3 05/16/2006 18:00:00 1.8 0.8 3.8 0.4 1.8 0.8 3.8 0.4 1.8 0.8 4.2 0.4 31 53 26 165 10.3 0.3 11.1 9.6 05/16/2006 18:10:00 2.5 0.7 4.2 0.7 2.4 0.7 4.2 0.7 2.5 0.7 4.2 0.7 0 30 333 165 9.7 0.5 11.1 8.8 05/16/2006 18:20:00 1.9 0.8 3.4 0.4 1.8 0.8 3.4 0.4 2 0.8 3.4 0.4 346 36 32 165 9 0.2 9.8 8.8 05/16/2006 18:30:00 3.1 0.4 4.2 2.3 3.2 0.4 4.2 2.3 2.7 0.6 4.6 1.1 292 7 292 165 9 0.2 10.1 8.8 05/16/2006 18:40:00 3 0.4 4.2 1.9 3.1 0.4 4.2 1.9 2.6 0.5 4.2 1.5 299 7 297 165 9.2 0.1 9.6 8.8 05/16/2006 18:50:00 3.3 0.5 4.2 1.9 3.3 0.5 4.2 1.9 2.8 0.5 4.2 1.5 306 11 294 165 8.9 0.1 9 8.5 05/16/2006 19:00:00 3 0.6 4.2 1.5 2.8 0.7 4.2 1.1 2.7 0.5 4.2 1.5 329 22 302 165 9.5 0.2 9.8 9 05/16/2006 19:10:00 4.3 0.6 5.7 3 4.4 0.7 5.7 3 3.6 0.5 4.9 2.6 301 9 294 165 8.8 0.5 9.6 8 05/16/2006 19:20:00 5.2 0.5 6.5 3.8 5.2 0.5 6.5 3.8 3.9 0.5 5.3 3 299 5 284 165 7.6 0.2 8.3 7.3 05/16/2006 19:30:00 5.3 0.4 6.5 4.2 5.4 0.4 6.5 4.6 4.1 0.5 5.3 3 298 5 294 165 6.6 0.3 7.8 6 05/16/2006 19:40:00 6 0.3 6.8 5.3 6.1 0.3 7.2 5.3 4.5 0.5 6.1 3.4 302 5 294 165 6 0.2 6.2 5.5 05/16/2006 19:50:00 6.1 0.6 7.6 4.6 6.1 0.6 7.6 4.6 4.6 0.5 6.1 3.4 303 5 302 165 5.7 0.1 6 5.2 05/16/2006 20:00:00 5.7 0.5 6.8 3.8 5.8 0.5 6.8 3.8 4.2 0.6 6.1 2.6 301 4 296 165 5.5 0 5.7 5 05/16/2006 20:10:00 5.5 0.5 6.8 4.6 5.6 0.5 6.8 4.6 4.2 0.6 6.5 2.6 302 5 301 165 5.2 0.1 5.5 5 05/16/2006 20:20:00 6 0.4 7.2 4.9 6.1 0.4 7.2 4.9 4.5 0.6 6.5 3.4 299 4 303 165 5.1 0 5.5 4.8 05/16/2006 20:30:00 5.8 0.7 7.6 4.2 5.9 0.7 7.2 4.2 4.4 0.5 6.1 3 299 5 297 165 4.8 0.1 5 4.3 05/16/2006 20:40:00 5.5 0.7 7.2 3 5.5 0.7 7.2 3 4.1 0.7 5.7 2.3 299 5 301 165 4.7 0 5 4.5 05/16/2006 20:50:00 5.5 0.6 6.8 4.2 5.5 0.6 7.2 4.2 4.4 0.7 6.8 2.6 295 6 301 165 4.6 0 4.8 4.5 05/16/2006 21:00:00 5.4 0.5 6.5 4.2 5.5 0.5 6.8 4.2 4.5 0.7 6.5 2.6 291 4 291 165 4.5 0 4.8 4.3 05/16/2006 21:10:00 4.5 0.6 6.1 3 4.7 0.6 6.1 3 3.8 0.8 6.1 1.9 290 4 293 165 4.3 0 4.5 4.3 05/16/2006 21:20:00 3.7 0.4 4.6 2.6 3.8 0.4 4.9 2.6 3 0.5 4.2 1.9 294 5 289 165 4.3 0 4.5 4 05/16/2006 21:30:00 3.5 0.6 4.9 1.9 3.6 0.6 5.3 2.3 2.7 0.6 4.2 1.5 295 6 287 165 4.3 0 4.5 4.3 05/16/2006 21:40:00 3.9 0.6 4.9 2.3 4 0.5 4.9 2.6 3 0.6 4.6 1.9 296 5 295 165 4.3 0 4.5 4.3 05/16/2006 21:50:00 3.6 0.5 4.6 2.3 3.7 0.5 4.6 2.3 2.9 0.5 4.2 1.5 294 5 295 165 4.4 0 4.5 4.3 05/16/2006 22:00:00 3.9 0.4 5.3 3 4.1 0.4 5.3 3 3.4 0.6 4.6 2.3 291 5 290 165 4.3 0 4.5 4.3 05/16/2006 22:10:00 4.4 0.3 4.9 3.4 4.6 0.4 5.3 3.8 4.4 0.4 4.9 3 281 4 282 165 4.2 0 4.5 4.3 05/16/2006 22:20:00 4.3 0.2 4.9 3.8 4.6 0.3 4.9 3.8 4.4 0.3 5.3 3.4 284 3 289 165 4.1 0 4.3 3.8 05/16/2006 22:30:00 4.5 0.4 5.7 3.8 4.7 0.4 6.1 3.8 4 0.7 5.7 2.6 291 5 284 165 4 0 4.3 3.5 05/16/2006 22:40:00 3.7 0.4 4.6 2.6 3.9 0.4 4.9 3 3.4 0.5 4.6 1.9 289 4 284 165 3.9 0.1 4.3 3.5 05/16/2006 22:50:00 3.3 0.3 4.2 2.3 3.5 0.3 4.2 2.6 3.2 0.4 4.2 2.3 287 4 289 165 3.8 0.1 4 3.5 05/16/2006 23:00:00 3 0.2 3.8 2.3 3.2 0.2 3.8 2.6 2.9 0.4 3.8 1.5 287 6 292 165 3.8 0.1 4 3.5 05/16/2006 23:10:00 2.2 0.4 3.4 0.7 2.5 0.4 3.8 1.1 1.8 0.4 3 1.1 296 5 292 165 3.7 0.1 4 3.3 05/16/2006 23:20:00 1.6 0.3 2.6 1.1 2 0.3 3 1.5 1.6 0.4 3 0.7 290 5 281 165 3.7 0.2 4 3.3 05/16/2006 23:30:00 1.9 0.3 3 1.1 2.3 0.3 3 1.9 2.2 0.3 3 1.1 283 3 282 165 3.8 0.1 4 3.3 05/16/2006 23:40:00 2.4 0.3 3 1.1 2.7 0.3 3.4 1.9 2.6 0.4 3.4 1.5 281 4 284 165 3.8 0.1 4.5 3 05/16/2006 23:50:00 2.3 0.3 3 1.9 2.6 0.2 3 1.9 2.6 0.2 3 1.9 277 6 267 165 3.8 0 4 3.3 05/17/2006 00:00:00 1.6 0.4 2.6 0.7 2 0.4 3 1.1 2 0.4 3 1.1 278 3 277 165 3.9 0 4.3 3.5 05/17/2006 00:10:00 1 0.4 1.9 0.4 1.5 0.4 2.3 0.7 1.4 0.3 1.9 0.7 268 8 277 165 4 0 4.3 3.8 05/17/2006 00:20:00 1.1 0.5 2.3 0.4 1.5 0.4 2.3 0.4 1.5 0.4 2.6 0.4 247 13 231 165 4 0 4.3 3.5 05/17/2006 00:30:00 1.3 0.5 2.3 0.4 1.5 0.4 2.3 0.4 1.7 0.3 2.3 0.7 221 10 235 165 3.7 0.1 4 3.3 05/17/2006 00:40:00 1.7 0.2 2.3 1.1 1.9 0.2 2.3 1.1 2 0.2 2.6 1.5 198 6 196 165 3.5 0.1 3.8 3 05/17/2006 00:50:00 1.6 0.4 2.3 0.4 1.8 0.3 2.6 0.7 2 0.3 2.6 1.1 183 11 200 165 3.4 0.1 3.5 3 05/17/2006 01:00:00 1.6 0.4 2.3 0.4 1.7 0.4 2.3 0.7 2 0.3 2.6 1.1 172 6 166 165 3.1 0 3.5 2.8 05/17/2006 01:10:00 1.8 0.3 2.6 1.1 1.9 0.3 2.6 1.1 2 0.3 2.6 1.5 171 5 174 165 2.9 0.2 3.3 2.3 05/17/2006 01:20:00 1.3 0.4 2.3 0.4 1.3 0.3 2.3 0.4 1.5 0.3 2.3 0.7 175 7 203 165 2.8 0 2.8 2.3 05/17/2006 01:30:00 1.3 0.4 2.3 0.4 1.6 0.4 2.3 0.4 1.6 0.3 2.3 0.7 209 14 220 165 2.8 0 3 2.6 05/17/2006 01:40:00 1.8 0.3 2.6 0.7 2 0.3 2.6 1.1 2.2 0.3 2.6 1.5 181 13 193 165 3 0.1 3.3 2.6 05/17/2006 01:50:00 1.4 0.3 2.3 0.7 1.6 0.2 2.3 1.1 1.8 0.2 2.3 1.5 163 2 163 165 2.5 0.1 2.8 2.3 05/17/2006 02:00:00 1.1 0.4 2.3 0.4 1.3 0.3 1.9 0.4 1.5 0.3 1.9 0.7 168 6 172 165 2.5 0 2.8 2.3 05/17/2006 02:10:00 1.6 0.6 3 0.4 1.6 0.6 3 0.4 1.7 0.5 2.6 0.4 157 17 165 165 2.7 0.1 3 2.3 05/17/2006 02:20:00 2.1 0.5 3 0.7 2.1 0.4 3 0.7 2.2 0.4 3.4 1.1 166 10 185 165 2.6 0.1 2.8 2.1 05/17/2006 02:30:00 2.5 0.5 3.4 1.1 2.5 0.5 3.4 1.5 2.6 0.4 3.4 1.1 183 8 193 165 2.7 0 2.8 2.6 05/17/2006 02:40:00 2.9 0.3 3.8 1.9 3.1 0.3 3.8 2.3 3 0.3 3.8 2.3 202 9 205 165 2.7 0 2.8 2.3 05/17/2006 02:50:00 2.2 0.4 3 1.5 2.4 0.4 3.4 1.9 2.4 0.3 3.4 1.9 223 2 216 165 2.4 0.1 2.8 1.8 05/17/2006 03:00:00 1.5 0.3 2.3 0.7 1.8 0.3 2.3 1.1 2 0.3 2.6 1.5 230 3 224 165 2.5 0 2.8 1.8 05/17/2006 03:10:00 0.8 0.4 1.9 0.4 1.2 0.5 1.9 0.4 1.5 0.4 2.3 0.4 235 9 213 165 2.7 0 2.8 2.1 05/17/2006 03:20:00 1.8 0.4 2.6 0.7 1.9 0.4 2.6 0.7 2 0.4 2.6 0.7 191 10 185 165 2.6 0 2.8 2.3 05/17/2006 03:30:00 1.3 0.6 2.6 0.4 1.5 0.7 2.6 0.4 1.7 0.6 3 0.4 193 10 196 165 2.6 0.1 2.8 2.3 05/17/2006 03:40:00 2.1 0.4 3 1.1 2.2 0.3 3 1.5 2.4 0.3 3 1.1 189 5 184 165 2.6 0.1 2.8 2.6 05/17/2006 03:50:00 1.4 0.4 2.3 0.7 1.6 0.4 2.6 1.1 1.9 0.4 2.6 1.1 210 5 216 165 2.4 0 2.8 2.3 05/17/2006 04:00:00 1.7 0.2 2.3 1.1 1.8 0.2 2.3 1.5 2.1 0.2 2.6 1.5 210 11 216 165 2.6 0 2.8 2.3 05/17/2006 04:10:00 1.1 0.6 2.3 0.4 1.2 0.6 2.3 0.4 1.6 0.4 2.6 0.7 188 2 193 165 2.6 0 2.8 2.6 05/17/2006 04:20:00 0.4 0 0.4 0.4 0.4 0.2 1.1 0.4 0.9 0.4 1.5 0.4 189 0 165 165 2.4 0 2.6 2.3 05/17/2006 04:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0.1 1.1 0.4 199 6 165 165 2.3 0 2.6 2.1 05/17/2006 04:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 226 18 165 165 2.1 0.1 2.6 1.8 05/17/2006 04:50:00 0.4 0 0.7 0.4 0.4 0.1 1.1 0.4 0.4 0.2 1.1 0.4 227 11 218 165 1.8 0 2.1 1.6 05/17/2006 05:00:00 0.5 0.3 1.5 0.4 0.7 0.4 1.9 0.4 0.9 0.4 1.9 0.4 227 8 243 165 2.5 0.4 3 1.8 05/17/2006 05:10:00 0.4 0.1 1.1 0.4 0.5 0.3 1.5 0.4 0.5 0.3 1.5 0.4 223 14 205 165 3.2 0.1 3.5 2.8 05/17/2006 05:20:00 1.5 0.4 2.3 0.7 1.6 0.3 2.6 1.1 1.7 0.3 2.6 0.7 199 11 205 165 3.5 0 3.5 3.3 05/17/2006 05:30:00 0.7 0.4 1.5 0.4 0.8 0.4 1.9 0.4 0.9 0.4 1.9 0.4 183 5 175 165 3.5 0.1 3.8 3.3 05/17/2006 05:40:00 0.6 0.3 1.5 0.4 0.7 0.4 1.5 0.4 0.6 0.3 1.5 0.4 243 51 304 165 4.1 0.1 4.5 3.5 05/17/2006 05:50:00 0.6 0.4 1.5 0.4 0.7 0.5 1.9 0.4 0.7 0.5 1.9 0.4 236 66 185 165 4.5 0.2 4.8 3.8 05/17/2006 06:00:00 0.7 0.5 1.9 0.4 0.8 0.6 1.9 0.4 0.9 0.6 2.3 0.4 157 0 157 165 4 0.3 5 3.5 05/17/2006 06:10:00 0.5 0.3 1.5 0.4 0.6 0.4 1.5 0.4 1 0.4 1.5 0.4 155 5 145 165 3.6 0 3.8 3.5 05/17/2006 06:20:00 0.9 0.4 1.5 0.4 1.1 0.4 1.5 0.4 1.2 0.2 1.9 0.7 126 9 139 165 3.9 0.2 4.3 3.3 05/17/2006 06:30:00 0.4 0 0.7 0.4 0.4 0.1 0.7 0.4 0.4 0.2 1.1 0.4 128 28 121 165 4.4 0.2 5 3.8 05/17/2006 06:40:00 0.4 0.2 1.5 0.4 0.4 0.1 1.1 0.4 0.4 0.2 1.1 0.4 268 51 154 165 5.7 0.3 6.2 4.8 05/17/2006 06:50:00 0.7 0.4 1.9 0.4 0.6 0.4 1.9 0.4 0.9 0.5 1.9 0.4 122 16 138 165 5.4 0.3 6.2 4.8 05/17/2006 07:00:00 1 0.6 2.3 0.4 1 0.6 2.3 0.4 1 0.7 2.6 0.4 105 24 126 165 5.6 0.3 6.2 5 05/17/2006 07:10:00 1.3 0.4 2.3 0.4 1.2 0.5 2.3 0.4 1.4 0.5 2.3 0.4 133 12 144 165 5.7 0.1 6.2 5.5 05/17/2006 07:20:00 1.5 0.6 2.6 0.4 1.4 0.6 3 0.4 1.6 0.6 3 0.4 149 11 161 165 5.7 0 5.7 5.5 05/17/2006 07:30:00 2.3 0.5 3.8 0.7 2.2 0.5 3.8 1.1 2.3 0.5 3.8 1.1 147 12 135 165 5.6 0 6 5.5 05/17/2006 07:40:00 2.4 0.5 3.8 0.7 2.4 0.5 3.8 0.7 2.5 0.5 3.4 1.1 142 17 124 165 5.9 0 6.2 5.5 05/17/2006 07:50:00 2.6 0.6 4.6 1.1 2.6 0.6 4.2 0.4 2.7 0.5 4.2 1.5 137 17 122 165 6.2 0.3 6.7 5.5 05/17/2006 08:00:00 2.9 0.6 4.6 1.1 2.8 0.6 4.9 1.1 2.9 0.7 4.9 1.1 171 13 145 165 6.2 0.2 7 5.7 05/17/2006 08:10:00 3.2 0.5 4.6 2.3 3.1 0.5 4.6 1.9 3.3 0.5 4.9 2.3 165 12 158 165 5.7 0.1 6 5.2 05/17/2006 08:20:00 2.9 0.5 4.9 1.9 2.9 0.5 4.2 1.5 2.9 0.5 4.2 1.5 167 13 162 165 5.5 0 5.7 5.2 05/17/2006 08:30:00 3.1 0.6 5.3 1.9 3 0.6 4.9 1.5 3.1 0.5 4.6 1.9 161 14 137 165 5.7 0.1 6 5.5 05/17/2006 08:40:00 2.4 0.7 3.8 0.7 2.3 0.7 3.8 0.7 2.4 0.7 3.8 0.7 171 18 162 165 5.6 0.2 6 5.2 05/17/2006 08:50:00 2.1 0.6 3.8 1.1 2 0.6 3.4 0.7 2.1 0.6 3.4 0.7 172 18 173 165 5.6 0.3 6 4.8 05/17/2006 09:00:00 2 0.7 4.2 0.4 1.9 0.8 3.8 0.4 2 0.9 4.2 0.4 176 27 139 165 6.3 0.1 6.7 5.7 05/17/2006 09:10:00 3.2 0.8 4.6 0.7 3.1 0.8 4.6 0.7 3.3 0.8 4.9 0.4 163 13 163 165 6.7 0 7 6.2 05/17/2006 09:20:00 3.8 0.6 5.3 2.3 3.8 0.6 5.7 1.9 3.7 0.7 5.3 1.9 156 11 145 165 7 0.2 7.5 6.7 05/17/2006 09:30:00 3.9 0.7 5.3 2.3 3.9 0.7 5.7 2.3 4 0.7 6.1 2.3 148 10 160 165 7.3 0.2 8 7 05/17/2006 09:40:00 3.7 0.8 5.3 1.9 3.7 0.8 6.1 1.9 3.9 0.6 5.7 2.6 145 11 164 165 7.1 0.1 7.8 6.7 05/17/2006 09:50:00 4.1 0.7 5.7 2.6 4.1 0.8 6.1 2.3 4.2 0.8 6.1 2.6 143 10 157 165 7.4 0.5 8.5 6.7 05/17/2006 10:00:00 3.8 0.5 5.3 2.3 3.8 0.5 4.9 2.3 3.9 0.6 5.3 2.3 142 9 156 165 7.3 0.2 7.8 6.7 05/17/2006 10:10:00 4.7 0.7 6.8 2.6 4.7 0.7 6.8 2.6 4.8 0.7 6.5 3.4 148 10 143 165 7.3 0 7.8 7.3 05/17/2006 10:20:00 5.1 0.5 6.8 4.2 5.1 0.5 6.8 4.2 5.2 0.5 6.5 4.2 142 9 143 165 7.4 0.1 8 7.3 05/17/2006 10:30:00 4.7 0.6 6.5 3 4.7 0.6 6.5 3 4.8 0.7 6.8 3 145 9 129 165 7.3 0.2 8 7 05/17/2006 10:40:00 4.4 0.6 6.1 3 4.4 0.6 6.1 3 4.6 0.6 6.1 3 144 8 139 165 7.7 0.1 8.3 7.5 05/17/2006 10:50:00 4.6 0.7 6.8 2.3 4.5 0.7 6.8 2.3 4.7 0.6 6.8 3 142 8 148 165 7.8 0 8.3 7.5 05/17/2006 11:00:00 4.8 0.7 6.5 3.4 4.8 0.7 6.8 3 4.8 0.7 6.8 2.6 143 10 133 165 8.3 0.2 8.8 7.5 05/17/2006 11:10:00 5.4 0.6 7.2 3.8 5.4 0.7 7.2 3.8 5.5 0.6 7.2 3.8 144 8 138 165 7.5 0.1 7.8 7.3 05/17/2006 11:20:00 5.3 0.7 7.6 4.2 5.3 0.7 7.6 3.8 5.4 0.7 7.2 4.2 144 8 132 165 8 0.3 8.5 7.5 05/17/2006 11:30:00 4.5 0.6 6.1 3 4.5 0.6 6.1 3.4 4.6 0.6 6.8 3.4 137 9 123 165 7.6 0.2 8 7.3 05/17/2006 11:40:00 4.6 0.9 6.8 2.6 4.6 0.9 7.2 2.6 4.6 0.9 7.6 2.3 139 9 160 165 7.5 0 8 7.3 05/17/2006 11:50:00 4.3 0.8 6.1 2.6 4.3 0.8 6.5 2.6 4.6 0.8 6.5 2.6 148 12 163 165 7.3 0 7.8 7 05/17/2006 12:00:00 4.7 0.7 6.1 3 4.6 0.7 6.1 3 4.7 0.8 6.1 3 152 7 154 165 7.8 0.5 9 7.3 05/17/2006 12:10:00 5.5 1.1 8.8 2.3 5.4 1.1 8.8 1.9 5.7 1.1 8.8 3 164 13 165 165 9.3 0.2 9.8 8.8 05/17/2006 12:20:00 7 0.8 8.8 4.9 6.8 0.8 8.8 4.6 7.2 0.8 9.1 4.9 166 8 164 165 9.1 0.3 9.6 8.8 05/17/2006 12:30:00 7.2 0.6 9.1 5.7 7 0.7 8.8 5.3 7.5 0.6 9.1 6.1 172 7 175 165 9.2 0.4 9.8 8.3 05/17/2006 12:40:00 7.5 0.7 9.9 5.7 7.4 0.7 9.9 5.7 7.8 0.8 10.7 6.1 173 7 172 165 8.5 0.3 9.3 8 05/17/2006 12:50:00 8.2 0.8 9.5 5.3 8 0.8 9.5 4.9 8.4 0.9 9.9 4.9 172 10 165 165 8.3 0.2 8.8 7.8 05/17/2006 13:00:00 8.2 1 11.1 5.7 8 1 10.7 5.7 8.4 1.1 11.8 6.1 176 9 189 165 8.3 0.1 9 8 05/17/2006 13:10:00 7.8 0.8 9.9 6.1 7.6 0.8 9.5 5.7 8 0.8 10.3 6.1 171 11 178 165 8.1 0.2 8.5 7.8 05/17/2006 13:20:00 8.3 0.4 9.9 6.5 8.1 0.4 9.9 6.8 8.6 0.5 10.3 6.5 167 6 171 165 8 0.1 8.5 7.5 05/17/2006 13:30:00 9.3 0.7 10.7 7.6 9.1 0.6 10.3 7.2 9.6 0.7 11.1 7.2 163 13 165 165 7.7 0 8 7.5 05/17/2006 13:40:00 9.9 0.6 11.5 8.4 9.6 0.5 10.7 8 10.1 0.6 11.5 8 166 14 161 165 7.7 0.2 8 7.3 05/17/2006 13:50:00 10.2 0.5 11.8 8.8 9.9 0.5 11.5 8.4 10.5 0.5 11.5 8.4 163 9 162 165 7.7 0.2 8.3 7.3 05/17/2006 14:00:00 9.8 0.6 11.1 8.4 9.5 0.6 11.1 8 10 0.8 11.5 7.6 164 10 164 165 7 0.1 7.3 7 05/17/2006 14:10:00 7.9 0.7 9.5 6.5 7.9 0.7 9.5 6.1 8 0.7 10.3 6.5 162 6 165 165 7.1 0.1 7.5 6.7 05/17/2006 14:20:00 7.7 0.7 9.5 6.1 7.6 0.7 9.5 5.7 7.9 0.7 9.9 5.7 168 5 173 165 7.3 0 7.5 7.3 05/17/2006 14:30:00 7.2 0.8 9.5 4.9 7.1 0.8 9.5 4.6 7.3 0.9 9.1 4.6 178 10 177 165 7.6 0 7.8 7.3 05/17/2006 14:40:00 8 0.8 10.3 5.7 7.8 0.8 10.3 5.7 8.3 0.7 9.9 6.5 179 8 178 165 7.3 0 7.8 7.3 05/17/2006 14:50:00 7 1 9.1 3.8 6.9 1 8.8 3.8 7.2 0.9 9.5 4.2 181 8 177 165 7.1 0 7.5 6.7 05/17/2006 15:00:00 6.5 0.8 8.4 3.8 6.4 0.8 8 3.8 6.7 0.8 8.8 4.6 181 9 179 165 7.2 0 7.5 7 05/17/2006 15:10:00 6.4 0.7 8.4 4.2 6.3 0.7 8.4 4.2 6.4 0.7 8.4 4.6 177 15 170 165 7.4 0 7.8 7.3 05/17/2006 15:20:00 7.3 1.2 9.5 4.6 7.2 1.2 9.9 4.2 7.5 1.4 9.9 4.6 167 7 171 165 7.4 0.2 7.8 6.7 05/17/2006 15:30:00 8.5 0.4 9.5 7.2 8.3 0.4 9.1 6.8 8.7 0.6 9.5 6.8 166 10 164 165 6.7 0 7 6.7 05/17/2006 15:40:00 8.4 0.5 9.5 6.5 8.2 0.5 9.5 6.8 8.6 0.5 9.9 6.5 166 11 164 165 6.9 0 7.3 6.7 05/17/2006 15:50:00 9.1 0.6 10.7 7.6 8.8 0.6 10.3 7.2 9.2 0.6 11.1 7.6 166 12 165 165 6.9 0.1 7.3 6.7 05/17/2006 16:00:00 9.1 0.6 10.3 7.6 8.8 0.5 10.3 7.2 9.3 0.6 10.7 7.6 165 11 166 165 6.8 0 7.3 6.5 05/17/2006 16:10:00 8.9 0.5 10.3 7.6 8.6 0.5 9.5 7.2 9.2 0.5 10.3 8 167 11 170 165 6.9 0.1 7 6.7 05/17/2006 16:20:00 8.4 0.7 9.9 6.5 8.2 0.6 9.5 6.5 8.6 0.7 10.3 6.8 167 6 169 165 7.4 0.3 7.8 6.7 05/17/2006 16:30:00 8.2 0.6 9.1 6.5 8 0.5 8.8 6.1 8.3 0.6 9.5 6.5 166 11 165 165 7 0.2 7.5 6.7 05/17/2006 16:40:00 7.5 0.6 9.1 6.1 7.3 0.6 8.8 5.7 7.5 0.7 9.1 6.1 167 9 167 165 7.3 0.2 7.8 7 05/17/2006 16:50:00 7.2 0.5 8.4 5.7 7 0.5 8.4 5.3 7.5 0.5 8.8 6.1 166 9 158 165 7.4 0.1 7.8 7.3 05/17/2006 17:00:00 7 0.4 8 6.1 6.8 0.4 7.6 5.7 7.2 0.5 8.8 6.1 164 9 162 165 7.1 0.1 7.8 7 05/17/2006 17:10:00 7.1 0.7 8.8 4.9 7 0.6 8.4 4.9 7.3 0.7 9.1 4.9 161 7 159 165 7.1 0 7.5 6.7 05/17/2006 17:20:00 7.7 0.7 8.8 5.3 7.5 0.6 8.8 4.9 8 0.6 9.1 6.1 164 8 162 165 7.3 0 7.5 7 05/17/2006 17:30:00 7.9 0.5 9.1 6.1 7.7 0.5 8.8 6.5 8 0.6 9.5 6.8 167 5 165 165 6.9 0 7.3 6.7 05/17/2006 17:40:00 7 0.5 8.4 5.3 6.8 0.5 8 5.3 7.2 0.6 8.4 5.7 168 6 165 165 6.9 0 7.3 6.7 05/17/2006 17:50:00 6.5 0.6 8 4.9 6.3 0.6 7.6 4.9 6.7 0.6 8.4 5.3 167 6 165 165 6.9 0 7.3 6.7 05/17/2006 18:00:00 5.8 0.6 7.2 4.6 5.6 0.6 6.8 4.2 5.9 0.7 7.2 4.6 166 5 165 165 6.9 0 7.3 6.7 05/17/2006 18:10:00 4.7 0.4 6.1 3.8 4.6 0.4 5.7 3.8 5 0.5 6.1 3.8 164 8 177 165 7.2 0 7.3 7 05/17/2006 18:20:00 4.4 0.6 6.1 3 4.4 0.5 5.7 3.4 4.7 0.6 5.7 3 171 6 180 165 7.3 0 7.5 7.3 05/17/2006 18:30:00 4.2 0.6 5.7 2.6 4.2 0.6 5.7 3 4.6 0.6 6.1 3 172 9 180 165 7.4 0 7.5 7.3 05/17/2006 18:40:00 3.5 0.6 5.3 1.9 3.7 0.6 5.7 1.9 3.7 0.6 5.3 2.3 196 16 196 165 7.6 0 7.8 7 05/17/2006 18:50:00 3.8 0.6 5.3 2.3 3.9 0.6 5.3 2.6 4 0.6 5.3 2.6 202 8 212 165 7.4 0 7.8 7.3 05/17/2006 19:00:00 3.1 0.8 4.6 1.5 3.3 0.6 4.6 1.9 3.3 0.7 4.9 1.5 212 20 194 165 7.3 0 7.5 7.3 05/17/2006 19:10:00 1.9 0.7 3.8 0.7 2.2 0.6 4.2 1.1 2.1 0.6 3.8 0.7 267 14 227 165 7.2 0.1 7.5 7 05/17/2006 19:20:00 2 0.7 3 0.7 2.3 0.5 3.4 1.1 2.3 0.5 3.4 1.1 268 6 276 165 6.9 0 7.3 7 05/17/2006 19:30:00 1.2 0.3 1.9 0.7 1.6 0.3 2.3 1.1 1.7 0.3 2.3 0.7 257 8 264 165 6.9 0 7.3 6.7 05/17/2006 19:40:00 1.5 0.5 3 0.4 1.8 0.5 3.4 0.4 1.9 0.4 3 1.1 248 15 250 165 6.9 0 7.3 6.7 05/17/2006 19:50:00 1.9 0.5 3 0.4 2.6 0.4 3.8 1.5 2.6 0.4 3.4 1.5 261 7 268 165 6.6 0.1 7 6 05/17/2006 20:00:00 2.1 0.4 3 0.7 2.5 0.3 3.4 1.9 2.5 0.3 3.4 1.9 269 5 274 165 6.5 0.1 6.7 6 05/17/2006 20:10:00 1.7 0.3 2.3 0.7 2 0.3 2.6 1.1 1.9 0.4 2.6 0.7 276 7 269 165 6.2 0.1 6.5 5.7 05/17/2006 20:20:00 0.7 0.4 1.5 0.4 0.7 0.4 1.9 0.4 0.8 0.4 1.5 0.4 304 24 302 165 6.1 0.2 6.2 5.5 05/17/2006 20:30:00 1.5 0.6 3 0.4 1.3 0.6 3 0.4 1.4 0.6 2.6 0.4 327 30 347 165 6 0 6.2 5.5 05/17/2006 20:40:00 1.2 0.5 2.3 0.4 1.3 0.5 2.6 0.4 1.2 0.5 2.3 0.4 294 17 339 165 5.8 0 6.2 5.7 05/17/2006 20:50:00 1.8 0.5 3.4 1.1 1.5 0.6 3.4 0.4 2 0.5 3.4 0.7 337 22 350 165 5.7 0 6 5.5 05/17/2006 21:00:00 3.9 0.8 5.3 1.9 3.6 0.9 5.7 1.1 3.7 0.7 5.3 2.3 349 6 350 165 5.6 0 5.7 5.5 05/17/2006 21:10:00 3.5 0.5 4.9 2.3 3.4 0.5 4.9 1.9 3.7 0.5 4.9 2.6 345 7 350 165 5.5 0 5.7 5.5 05/17/2006 21:20:00 4 0.7 5.7 2.3 3.9 0.9 6.1 1.5 4.2 0.6 5.7 2.6 346 7 349 165 5.4 0 5.7 5.2 05/17/2006 21:30:00 4.3 0.6 6.1 2.6 4.3 0.6 6.1 2.6 4.1 0.6 6.1 3 334 10 344 165 5.4 0 5.7 5 05/17/2006 21:40:00 4.9 0.6 6.5 3.4 4.9 0.7 6.5 3 5 0.7 6.8 3.4 341 8 340 165 5.3 0 5.5 4.8 05/17/2006 21:50:00 4 0.8 6.1 2.3 4 0.8 6.1 2.3 4.1 0.7 5.7 2.6 339 7 332 165 5.3 0 5.5 4.8 05/17/2006 22:00:00 2.3 0.5 3.4 1.1 2.4 0.4 3.8 1.5 2.4 0.5 3.8 1.1 325 12 338 165 5.2 0.1 5.5 4.8 05/17/2006 22:10:00 2.1 0.5 3 1.1 2.3 0.5 3.4 1.1 2.4 0.4 3.4 1.5 317 9 332 165 5.1 0 5.5 4.8 05/17/2006 22:20:00 2.2 0.4 3.4 1.5 2.3 0.4 3.4 1.5 2.3 0.3 3 1.5 325 15 309 165 4.9 0 5 4.5 05/17/2006 22:30:00 2.5 0.4 3.8 1.5 2.5 0.5 3.8 1.5 2.5 0.5 3.8 1.1 329 17 336 165 4.9 0.1 5 4.5 05/17/2006 22:40:00 1.8 0.5 3 0.4 1.9 0.5 3 0.7 2.1 0.5 3 0.7 327 15 360 165 4.8 0 5 4.5 05/17/2006 22:50:00 2.4 0.7 3.8 1.1 2.5 0.8 4.2 0.7 2.7 0.6 4.2 1.5 340 15 344 165 4.9 0.2 5.5 4.5 05/17/2006 23:00:00 1.9 0.6 3.4 0.4 2 0.6 3.8 0.4 2.4 0.6 4.2 0.4 348 21 360 165 4.9 0.2 5.2 4.5 05/17/2006 23:10:00 1.9 0.6 3.4 0.7 1.9 0.7 3.4 0.4 2.3 0.5 3.4 1.5 348 9 349 165 4.8 0.1 5.5 4.5 05/17/2006 23:20:00 1.2 0.6 3 0.4 1.5 0.6 3.4 0.4 1.8 0.5 3 0.4 318 19 339 165 4.8 0.2 5.2 4.5 05/17/2006 23:30:00 1.5 0.5 2.6 0.4 1.7 0.5 3 0.4 1.9 0.4 3 0.7 307 21 282 165 4.8 0.1 5 4.3 05/17/2006 23:40:00 1.3 0.6 2.6 0.4 1.6 0.6 3 0.4 1.6 0.4 2.6 0.7 305 17 346 165 4.8 0.1 5 4.5 05/17/2006 23:50:00 1 0.5 2.3 0.4 1.2 0.5 2.3 0.4 1.5 0.4 2.3 0.4 311 19 316 165 4.6 0.1 5 4.3 05/18/2006 00:00:00 2 0.4 3.4 1.1 2.4 0.3 3.4 1.5 2.3 0.4 3 1.5 303 10 311 165 4.6 0.1 5.2 4.3 05/18/2006 00:10:00 2.5 0.5 3.8 1.1 2.8 0.5 4.2 1.5 2.5 0.4 3.8 1.5 299 8 289 165 4.6 0.1 5 4.3 05/18/2006 00:20:00 2.9 0.8 4.6 0.7 3.1 0.8 4.9 1.1 2.7 0.6 4.6 1.1 306 10 287 165 4.6 0.1 4.8 4.3 05/18/2006 00:30:00 2.3 0.7 3.8 0.7 2.7 0.6 4.2 1.1 2.5 0.6 4.2 1.1 300 10 293 165 4.6 0 4.8 4.3 05/18/2006 00:40:00 3.8 0.8 5.3 1.9 4 0.8 5.3 1.9 3.2 0.6 4.9 1.9 296 5 302 165 4.6 0 4.8 4.5 05/18/2006 00:50:00 4.3 0.6 5.7 3 4.5 0.6 5.7 3 3.5 0.6 4.9 2.3 298 7 298 165 4.6 0 4.8 4.5 05/18/2006 01:00:00 4.4 0.6 5.7 3 4.6 0.6 5.7 3 3.4 0.5 4.9 2.3 297 6 295 165 4.7 0 4.8 4.5 05/18/2006 01:10:00 3.3 0.4 4.2 2.3 3.5 0.4 4.6 2.3 2.9 0.4 4.2 1.9 298 5 297 165 4.6 0 4.8 4.5 05/18/2006 01:20:00 2 0.3 3 1.1 2.3 0.3 3 1.5 2.1 0.4 3 1.5 300 9 295 165 4.6 0 4.8 4.5 05/18/2006 01:30:00 1.5 0.5 2.6 0.4 1.5 0.6 3 0.4 1.7 0.5 3 0.4 332 20 351 165 4.8 0 5 4.5 05/18/2006 01:40:00 1 0.5 2.3 0.4 1.1 0.6 2.3 0.4 1.5 0.4 2.6 0.4 317 18 314 165 4.8 0 5 4.5 05/18/2006 01:50:00 1.1 0.5 2.3 0.4 1.3 0.6 2.6 0.4 1.6 0.5 3 0.4 299 18 285 165 4.8 0 5 4.5 05/18/2006 02:00:00 1.5 0.6 2.6 0.4 1.8 0.6 3 0.4 2.1 0.6 3.4 0.7 299 13 286 165 4.7 0.1 5 4.3 05/18/2006 02:10:00 2.1 0.9 4.2 0.4 2.4 0.8 4.6 0.4 2.9 0.8 4.6 1.1 287 9 280 165 4.7 0 5 4.5 05/18/2006 02:20:00 3.1 0.7 4.9 1.1 3.4 0.7 4.9 1.5 3.5 0.6 4.9 1.9 290 7 292 165 4.6 0 4.8 4.3 05/18/2006 02:30:00 2.7 0.7 4.2 1.1 3 0.7 4.6 1.5 3.2 0.5 4.6 1.9 287 7 282 165 4.6 0 4.8 4.3 05/18/2006 02:40:00 2.6 0.5 3.8 1.1 2.9 0.5 3.8 1.5 3.1 0.5 4.2 1.5 286 6 282 165 4.6 0 4.8 4.3 05/18/2006 02:50:00 3.5 0.5 4.9 1.9 3.8 0.5 5.3 2.3 3.6 0.6 5.3 2.3 289 6 286 165 4.6 0 4.8 4.5 05/18/2006 03:00:00 3.7 0.6 5.3 1.9 3.9 0.6 5.3 2.3 3.9 0.7 5.3 2.3 285 10 280 165 4.6 0 4.8 4.5 05/18/2006 03:10:00 4.5 0.8 6.5 2.6 4.6 0.8 6.8 2.6 4 0.9 6.5 1.9 292 8 284 165 4.7 0.1 5 4.3 05/18/2006 03:20:00 4.3 0.7 6.5 2.3 4.5 0.8 6.5 2.3 3.9 0.9 6.1 2.3 293 7 282 165 4.6 0 4.8 4.5 05/18/2006 03:30:00 4.7 0.8 6.5 3 4.8 0.8 6.5 3 4.5 0.8 6.8 2.3 290 8 302 165 4.7 0 4.8 4.5 05/18/2006 03:40:00 6.8 0.9 8.8 3 6.9 0.9 8.8 3 5.3 0.8 7.6 3 295 7 299 165 4.6 0 4.8 4.3 05/18/2006 03:50:00 7.8 0.8 9.1 4.9 7.9 0.8 9.5 4.9 5.6 0.7 7.6 3.4 301 4 301 165 4.6 0 4.8 4.3 05/18/2006 04:00:00 7.8 0.6 9.1 5.7 7.9 0.7 9.1 5.7 6.1 0.9 8.8 4.2 304 5 301 165 4.6 0 4.8 4.3 05/18/2006 04:10:00 8.1 0.6 9.5 5.7 8.2 0.6 9.5 5.7 6.1 0.7 8.4 4.6 305 4 306 165 4.5 0 4.8 4.3 05/18/2006 04:20:00 7.2 0.7 8.8 4.9 7.2 0.7 8.8 5.3 5.7 0.6 7.2 4.2 305 6 302 165 4.4 0.1 4.5 4 05/18/2006 04:30:00 7.4 0.9 9.1 5.3 7.5 0.9 9.1 4.9 6.1 0.8 8.4 3.8 305 6 302 165 4.4 0.1 4.8 4 05/18/2006 04:40:00 7.4 1 9.1 5.3 7.4 1 9.1 4.9 5.9 0.8 8.4 3.4 307 5 309 165 4.5 0.1 4.8 4.3 05/18/2006 04:50:00 7.7 0.7 9.5 6.1 7.7 0.7 9.5 5.7 6.6 0.8 8.8 4.6 310 4 321 165 4.6 0.1 4.8 4.3 05/18/2006 05:00:00 7.5 0.8 9.1 5.3 7.5 0.7 9.1 5.3 5.8 0.7 8.4 4.2 303 4 301 165 4.5 0.1 4.8 4.3 05/18/2006 05:10:00 7.1 0.9 8.8 4.6 7.1 0.9 8.8 4.6 5.6 0.7 8 4.2 305 6 316 165 4.6 0.1 4.8 4.3 05/18/2006 05:20:00 7.6 1 9.9 4.6 7.7 1 9.5 4.6 6 0.9 8.4 3.8 302 8 297 165 4.6 0.1 4.8 4.3 05/18/2006 05:30:00 8.3 0.7 9.5 5.7 8.3 0.7 9.9 6.1 6.3 0.8 9.5 4.2 303 6 295 165 4.6 0.1 4.8 4.3 05/18/2006 05:40:00 8.3 0.6 9.9 6.5 8.3 0.6 9.9 6.5 6 0.7 8.4 4.6 299 4 292 165 4.5 0.1 4.8 4.3 05/18/2006 05:50:00 8.9 0.7 10.7 7.2 9 0.7 10.7 7.2 6.6 0.8 9.1 4.9 297 4 298 165 4.6 0.1 4.8 4.3 05/18/2006 06:00:00 9.3 0.5 10.3 8 9.4 0.5 10.7 8 6.4 0.6 8.4 5.3 301 3 297 165 4.6 0.1 4.8 4.3 05/18/2006 06:10:00 9.3 0.6 10.3 6.8 9.4 0.6 10.7 6.8 6.3 0.5 8 4.9 301 3 305 165 4.7 0.1 5 4.3 05/18/2006 06:20:00 9.1 0.6 10.3 7.2 9.1 0.6 10.3 7.2 6.5 0.8 9.5 4.6 302 4 301 165 4.8 0 5 4.5 05/18/2006 06:30:00 8.5 0.6 9.9 6.8 8.6 0.6 9.9 6.5 6.3 0.8 8.8 4.6 299 5 300 165 4.9 0 5 4.5 05/18/2006 06:40:00 8 0.8 10.3 6.1 8.1 0.8 10.3 6.1 6.5 0.8 8.4 4.6 296 6 298 165 4.9 0 5 4.8 05/18/2006 06:50:00 7.6 0.9 10.3 5.7 7.7 0.9 10.3 5.7 6.2 0.8 9.1 4.2 297 7 301 165 5 0 5.2 4.5 05/18/2006 07:00:00 9.2 1 11.5 7.2 9.3 1 11.5 6.8 6.8 0.8 8.8 4.9 299 5 301 165 5 0 5.2 4.5 05/18/2006 07:10:00 9.9 0.6 11.1 7.6 10 0.6 11.1 7.6 6.9 0.7 8.8 4.9 301 3 301 165 5 0 5.2 4.5 05/18/2006 07:20:00 9.6 1 11.5 7.2 9.7 1 11.5 7.2 7 0.8 9.5 4.6 304 4 302 165 5.1 0 5.2 4.8 05/18/2006 07:30:00 8.4 0.8 10.3 6.1 8.4 0.8 10.3 6.1 6.4 0.8 8.8 4.6 303 5 305 165 5.2 0.1 5.5 4.8 05/18/2006 07:40:00 8.9 0.8 10.3 6.8 8.9 0.9 10.7 6.8 6.8 0.8 9.5 4.2 303 5 305 165 5.4 0.1 5.7 4.8 05/18/2006 07:50:00 8 0.8 9.9 6.1 8.1 0.8 9.9 6.1 6.2 0.8 8.4 4.2 303 5 308 165 5.4 0.1 5.7 5 05/18/2006 08:00:00 8 0.9 9.9 5.3 8.1 0.9 10.3 5.7 6.3 0.8 8 4.2 303 6 302 165 5.6 0 5.7 5.5 05/18/2006 08:10:00 8.1 0.8 10.3 5.7 8.1 0.8 9.9 6.1 6.4 0.9 8.8 4.6 304 5 310 165 5.7 0.1 6 5.2 05/18/2006 08:20:00 8.1 0.9 10.7 5.3 8.1 0.9 10.3 5.3 6.3 1 9.1 4.2 304 5 301 165 5.7 0.1 6 5.5 05/18/2006 08:30:00 7.4 1 9.5 4.6 7.5 1 9.5 4.6 5.7 0.8 8 3.8 300 6 303 165 6 0.2 6.2 5.2 05/18/2006 08:40:00 8.1 0.5 9.1 6.5 8.1 0.5 9.5 6.5 6.7 0.8 8.8 4.6 303 7 296 165 6.2 0.1 6.5 5.7 05/18/2006 08:50:00 7.7 0.6 9.5 6.1 7.7 0.7 9.1 5.7 5.9 0.8 8.4 3.8 304 5 302 165 6.3 0.1 6.5 5.7 05/18/2006 09:00:00 7.9 0.7 9.1 5.3 7.9 0.7 9.1 5.7 6 0.7 8 4.2 302 5 299 165 6.3 0 6.5 6.2 05/18/2006 09:10:00 6.9 0.7 9.1 5.3 6.9 0.7 9.5 4.9 5.8 0.8 7.6 3.4 306 6 303 165 6.3 0 6.5 6.2 05/18/2006 09:20:00 6.2 0.7 7.6 4.6 6.1 0.7 7.6 4.6 5.6 0.7 7.6 3.8 309 6 304 165 6.5 0 6.7 6 05/18/2006 09:30:00 5.3 0.8 8 3.8 5.3 0.8 8 3.4 5.1 0.9 7.6 3.4 310 7 315 165 6.7 0.1 7.3 6.2 05/18/2006 09:40:00 5.3 1 8.8 3 5.3 1 8.4 3 4.5 1.1 8 2.3 301 11 321 165 7.4 0.3 8 6.7 05/18/2006 09:50:00 4.9 0.5 6.8 3.8 4.9 0.6 7.2 3.8 3.9 0.6 6.1 2.6 299 7 293 165 7.6 0.1 8 7.3 05/18/2006 10:00:00 5 0.5 6.5 3.8 5 0.5 6.5 3.4 4 0.6 5.7 2.6 298 5 304 165 7.5 0 7.8 7.3 05/18/2006 10:10:00 4.7 0.5 6.5 3.4 4.7 0.6 6.5 3 3.9 0.6 5.7 2.3 300 7 301 165 7.5 0.2 8 7.3 05/18/2006 10:20:00 4.3 0.8 6.5 2.6 4.2 0.8 6.1 2.6 3.7 0.9 6.5 1.5 297 13 297 165 8.3 0 8.5 8 05/18/2006 10:30:00 4.2 1 6.1 2.3 4.2 1 6.5 1.9 3.8 1.1 6.5 1.5 305 17 316 165 8.9 0.5 9.8 8 05/18/2006 10:40:00 4.9 1.2 7.2 1.9 5 1.3 7.6 1.9 4.5 1.2 7.6 1.9 290 14 307 165 8.3 0.5 9.3 7.5 05/18/2006 10:50:00 5.1 1 8 1.9 5.1 1 8 1.9 4.5 1 6.8 1.9 297 17 308 165 8.2 0 8.5 7.8 05/18/2006 11:00:00 5.3 0.8 6.8 3 5.3 0.8 6.8 3 5 0.9 6.8 2.6 315 8 322 165 9.1 0.7 10.3 8.3 05/18/2006 11:10:00 4.8 0.9 6.8 2.6 4.9 0.8 6.8 2.6 4.3 0.9 6.8 1.9 303 20 290 165 10.7 0.3 11.4 9.8 05/18/2006 11:20:00 5.5 0.9 7.6 1.5 5.6 0.9 7.2 1.1 5 0.8 7.2 2.6 309 9 310 165 9.4 0.5 10.9 8.8 05/18/2006 11:30:00 5.7 0.7 7.2 3.8 5.8 0.7 7.2 3.8 5.3 0.7 6.8 3.4 311 7 317 165 8.3 0.1 8.8 8 05/18/2006 11:40:00 5 0.9 7.2 2.6 5.1 0.9 7.2 2.3 4.6 1 6.8 2.6 316 8 307 165 8.3 0.3 9 8 05/18/2006 11:50:00 5.1 0.7 6.5 3.4 5.1 0.7 6.5 3.4 4.8 0.6 6.5 3.4 314 11 314 165 8.7 0 9 8.5 05/18/2006 12:00:00 4.8 1.1 7.2 2.6 4.9 1.1 7.6 2.3 4.4 1.2 6.8 1.5 312 13 316 165 8.9 0.2 9.3 8.5 05/18/2006 12:10:00 6.4 1.7 9.1 2.3 6.4 1.7 9.5 2.3 5.6 1.6 9.1 1.9 310 12 299 165 8.9 0.3 9.3 8.5 05/18/2006 12:20:00 6.5 1.1 8.8 3.8 6.5 1.1 8.8 3.8 5.9 1.2 9.1 3 313 8 314 165 8.9 0.2 9 8.5 05/18/2006 12:30:00 6.9 1 9.1 4.2 7 1 9.1 4.2 6.1 1.2 9.1 3.4 300 12 312 165 8.7 0 9 8.5 05/18/2006 12:40:00 7.4 1.2 11.1 4.9 7.5 1.2 10.7 4.9 6.6 1.3 10.3 3.8 296 12 300 165 7.8 0.2 8.5 7.5 05/18/2006 12:50:00 7.1 1.2 9.9 4.2 7.2 1.2 9.9 4.6 6.3 1.5 9.9 3.4 291 12 284 165 7.6 0.2 8.5 7 05/18/2006 13:00:00 6.3 1.3 10.3 3.8 6.3 1.3 9.9 3.8 5.5 1.3 8.8 3 307 14 292 165 8.1 0.1 8.5 7.8 05/18/2006 13:10:00 7 0.8 9.1 4.6 7 0.8 8.8 4.6 6.1 0.9 8.8 3.4 309 8 302 165 8.1 0.2 8.5 8 05/18/2006 13:20:00 5.9 1.4 9.5 2.6 5.9 1.4 9.1 2.6 4.9 1.2 8.4 2.3 307 10 302 165 8.1 0.2 8.5 7.8 05/18/2006 13:30:00 5.5 1.2 8.8 2.3 5.4 1.3 8.4 1.5 4.9 1.5 8 0.4 323 13 321 165 9.6 0.5 10.6 8.5 05/18/2006 13:40:00 6.3 1 8.4 3.8 6.2 1 8.4 3.8 5.8 1 8 3.4 325 12 317 165 10.7 0.1 11.4 10.6 05/18/2006 13:50:00 6.8 1 9.9 4.2 6.8 1 9.9 4.6 6.2 1 9.9 3 314 9 331 165 11.3 0.1 11.9 11.1 05/18/2006 14:00:00 7.5 1.2 10.7 4.6 7.4 1.2 10.3 4.6 7.1 1.4 10.3 3.8 321 11 326 165 11.4 0 11.9 11.1 05/18/2006 14:10:00 8 1.2 11.1 4.9 7.9 1.2 10.7 4.9 7.6 1.2 10.7 4.6 322 10 314 165 11.3 0.2 11.9 10.9 05/18/2006 14:20:00 8.6 1.1 10.7 4.9 8.5 1.1 11.1 4.9 8.2 1.2 11.5 4.2 320 8 315 165 10.8 0.2 11.4 10.3 05/18/2006 14:30:00 7.6 1.4 10.7 3.8 7.6 1.3 10.7 4.2 7 1.5 9.9 3.8 314 7 319 165 10.9 0.1 11.4 10.6 05/18/2006 14:40:00 8.4 0.9 10.7 5.7 8.3 0.9 10.7 6.1 7.7 1 10.3 5.3 316 8 304 165 10.9 0 11.1 10.9 05/18/2006 14:50:00 9.3 0.7 11.1 7.2 9.2 0.7 11.5 7.2 9 0.8 10.7 6.1 322 6 311 165 11.1 0.2 11.7 10.6 05/18/2006 15:00:00 9.2 0.6 10.7 6.8 9.2 0.6 10.3 6.8 8.8 1 10.7 5.3 317 6 320 165 10.5 0 11.1 10.3 05/18/2006 15:10:00 9.7 0.7 11.8 7.2 9.6 0.7 11.8 7.6 9.3 0.9 11.5 6.5 319 5 316 165 10.4 0.2 11.1 10.1 05/18/2006 15:20:00 9.1 0.8 11.5 6.5 9.1 0.8 11.1 6.5 8.9 1 11.1 5.3 318 6 314 165 10.2 0.1 10.9 9.8 05/18/2006 15:30:00 8.7 0.9 11.5 6.5 8.6 0.8 11.1 6.5 8.5 0.9 11.1 6.1 318 6 322 165 10.3 0 10.6 10.3 05/18/2006 15:40:00 7.6 1 10.3 4.9 7.5 0.9 10.3 4.9 7.5 1.1 10.3 4.9 318 7 319 165 10.5 0.1 10.9 10.3 05/18/2006 15:50:00 8.3 0.8 11.1 6.8 8.3 0.8 10.7 6.5 8 0.8 9.9 5.3 320 6 322 165 10.6 0.2 11.1 10.3 05/18/2006 16:00:00 8.3 0.9 10.3 6.1 8.3 0.9 9.9 6.1 8.1 1 9.9 5.7 319 6 319 165 10.6 0 11.1 10.3 05/18/2006 16:10:00 8.8 0.7 11.1 6.8 8.7 0.7 10.7 6.5 8.6 0.8 10.3 6.5 320 6 323 165 10.5 0 10.9 10.3 05/18/2006 16:20:00 9.3 0.7 11.1 7.2 9.3 0.7 10.7 7.2 9 0.8 11.1 7.2 318 7 315 165 10.3 0.1 10.9 10.1 05/18/2006 16:30:00 9 0.9 10.7 6.5 9 0.9 10.7 6.5 8.6 1.1 11.1 5.3 316 7 308 165 10.1 0 10.9 9.8 05/18/2006 16:40:00 9.1 1.2 11.8 4.9 9.1 1.2 11.8 5.3 8.7 1.3 11.5 4.9 317 7 313 165 10 0.3 10.6 9.6 05/18/2006 16:50:00 9.7 1 12.2 6.1 9.6 1.1 11.8 6.1 9.2 1.3 14.1 5.7 316 6 331 165 9.9 0 10.3 9.6 05/18/2006 17:00:00 10.8 1.2 13.3 6.8 10.7 1.1 13.3 6.8 9.7 1.3 13.3 5.7 314 8 309 165 9.7 0.1 10.1 9.3 05/18/2006 17:10:00 10.8 1.5 13.3 6.5 10.8 1.4 13.3 6.8 9.8 1.6 13.3 6.1 315 10 320 165 9.6 0.1 9.8 9.3 05/18/2006 17:20:00 10.6 1.1 12.6 7.2 10.5 1 12.6 6.8 10.3 1.2 13.3 6.1 318 6 313 165 9.8 0 10.1 9.6 05/18/2006 17:30:00 9.8 1.3 13 6.5 9.7 1.3 13 6.5 9.1 1.3 12.2 4.9 315 9 309 165 9.7 0.1 10.1 9.3 05/18/2006 17:40:00 9.5 1.1 12.2 6.5 9.5 1.1 11.8 6.5 9 1.5 12.2 5.7 314 7 305 165 9.5 0 9.8 9 05/18/2006 17:50:00 10.5 0.8 13 8 10.5 0.8 13.3 8 10 1.1 12.6 6.8 317 7 315 165 9.4 0 9.8 9 05/18/2006 18:00:00 11.1 1.1 13.7 6.8 11 1.1 13.3 7.2 10.7 1.3 13.7 7.2 320 8 325 165 9.3 0.1 9.6 9 05/18/2006 18:10:00 10.8 1.6 14.1 6.1 10.7 1.6 14.1 4.6 10.3 1.7 14.1 4.6 321 12 316 165 9.4 0 9.6 9 05/18/2006 18:20:00 12 1.2 14.9 8.8 11.9 1.2 14.9 8.4 11.5 1.3 14.9 8.4 317 6 318 165 9 0 9.3 8.8 05/18/2006 18:30:00 11.8 1.5 15.3 7.6 11.7 1.5 15.3 7.6 11.4 1.5 14.9 7.2 319 6 307 165 8.8 0 9 8.5 05/18/2006 18:40:00 13.2 1.2 16.1 9.5 13 1.2 16.1 9.1 12.9 1.4 16.1 8 318 5 312 165 8.5 0 8.8 8.5 05/18/2006 18:50:00 11.5 1.1 14.9 9.1 11.4 1 14.9 8.8 10.8 1.2 14.1 7.6 317 8 310 165 8.5 0 8.8 8.3 05/18/2006 19:00:00 9.6 1.5 13.3 6.5 9.5 1.5 13.3 6.1 9 1.5 13.7 6.1 317 9 324 165 8.6 0 8.8 8 05/18/2006 19:10:00 8.7 1.1 11.5 5.7 8.7 1 11.5 6.1 7.8 1.2 11.1 4.6 311 10 305 165 8.7 0.1 9 8.3 05/18/2006 19:20:00 8.5 1.2 10.7 5.3 8.4 1.2 10.7 5.3 8.2 1.2 10.7 4.6 315 8 313 165 8.5 0 8.5 8.3 05/18/2006 19:30:00 8.9 0.8 10.7 6.5 8.8 0.8 10.7 6.5 8.5 1 11.1 5.7 313 7 314 165 8.2 0.2 8.5 7.8 05/18/2006 19:40:00 10.3 1 12.6 7.6 10.3 1.1 12.6 7.6 8.2 1 11.1 5.7 304 7 298 165 7.8 0.1 8.3 7.3 05/18/2006 19:50:00 9.8 0.9 12.2 7.2 9.9 0.9 12.2 7.2 7.5 0.9 10.3 5.3 303 6 296 165 7.5 0 7.8 7 05/18/2006 20:00:00 8.8 1.2 11.8 5.7 8.8 1.2 11.5 5.7 7 1 9.5 4.6 303 7 297 165 7.4 0.1 7.8 7 05/18/2006 20:10:00 8.7 0.9 10.7 6.1 8.6 0.9 10.7 6.5 7.2 1.1 9.9 4.6 305 9 314 165 7.3 0 7.5 7.3 05/18/2006 20:20:00 6.1 1.4 9.1 2.3 6.1 1.3 8.8 1.9 5.2 1.4 9.1 1.9 307 12 316 165 7.1 0.1 7.3 7 05/18/2006 20:30:00 4.3 1.2 8 1.5 4.4 1.2 8.4 0.7 3.3 1.1 7.2 0.7 305 15 308 165 6.8 0 7 6.7 05/18/2006 20:40:00 3.6 1 6.5 1.9 3.6 1 6.5 1.9 3.1 0.9 6.1 1.5 306 14 300 165 6.4 0.1 7 6 05/18/2006 20:50:00 3.5 0.6 4.9 1.9 3.4 0.6 5.3 1.5 3.2 0.6 4.9 1.5 326 17 328 165 6.1 0 6.7 5.7 05/18/2006 21:00:00 3.9 1 6.5 1.5 3.8 1 6.5 1.5 3.4 0.9 5.7 1.1 317 14 323 165 5.7 0.2 6 5.2 05/18/2006 21:10:00 5.7 1.1 8 3.4 5.7 1.1 8 3.4 5 1.2 8 2.3 309 9 311 165 5.4 0.1 5.7 5 05/18/2006 21:20:00 8 1.2 10.3 4.2 8 1.2 10.3 4.2 6.8 1.2 9.5 3.4 305 9 305 165 5.7 0.1 5.7 5 05/18/2006 21:30:00 8.3 0.8 10.3 6.5 8.3 0.8 10.3 6.5 7.2 1 10.7 4.9 309 6 305 165 5.6 0 6 5.2 05/18/2006 21:40:00 8.1 1.3 11.5 4.9 8.1 1.4 11.5 5.3 6.9 1.3 11.8 4.2 306 10 307 165 5.6 0.1 5.7 5.2 05/18/2006 21:50:00 8.5 1.4 11.8 4.6 8.5 1.4 11.8 4.9 7.2 1.4 9.9 3.8 307 9 300 165 5.4 0 5.7 5 05/18/2006 22:00:00 8.1 1.5 11.8 4.6 8.1 1.5 11.1 4.6 6.6 1.3 10.7 3 299 8 310 165 5.4 0.1 5.7 5 05/18/2006 22:10:00 8.8 1.3 11.8 5.3 8.8 1.2 12.2 5.7 7.4 1.3 12.2 4.6 307 7 311 165 5.7 0.1 5.7 5 05/18/2006 22:20:00 8.5 1 10.7 5.3 8.4 1 11.1 4.9 7.5 1 9.9 4.9 310 7 312 165 5.4 0.2 5.7 5 05/18/2006 22:30:00 8.8 0.9 11.8 6.8 8.8 0.9 11.8 6.5 7.5 1 10.7 4.9 308 7 299 165 5.1 0 5.5 4.8 05/18/2006 22:40:00 9.2 1 11.5 6.8 9.2 1 11.8 6.8 7.9 1 10.7 5.3 309 6 301 165 5.1 0 5.5 4.8 05/18/2006 22:50:00 9.6 1.2 12.6 6.8 9.7 1.2 13 6.8 7.9 1.3 11.5 4.9 304 7 303 165 5.1 0.1 5.5 4.8 05/18/2006 23:00:00 10.7 1.3 14.1 8 10.7 1.3 14.9 8 9.1 1.4 13.3 5.7 306 7 300 165 5.2 0 5.5 5 05/18/2006 23:10:00 10.5 0.9 13.3 8 10.5 1 13.3 8.4 9.5 1 12.2 6.8 312 6 307 165 5.2 0.1 5.5 4.8 05/18/2006 23:20:00 11.4 1 14.1 8 11.4 1 14.1 8 10.1 1.2 13.3 7.2 310 5 306 165 4.9 0 5 4.5 05/18/2006 23:30:00 10.9 0.9 13.3 8 10.9 0.9 13.3 8 9.4 1.3 13 6.8 309 6 310 165 4.8 0.1 5.5 4.5 05/18/2006 23:40:00 10.7 1.1 13.3 8.4 10.7 1.1 13.3 8 9 1.2 12.2 6.5 309 5 310 165 4.8 0.1 5 4.5 05/18/2006 23:50:00 11 1.1 13.3 8.4 11 1.1 13.7 7.6 9.7 1.3 13 6.5 310 7 305 165 4.8 0 5 4.5 05/19/2006 00:00:00 10.8 0.9 13 8.8 10.8 0.9 12.6 8.8 9.8 1.1 13 6.8 312 6 308 165 4.6 0.1 5 4.3 05/19/2006 00:10:00 10.5 0.7 12.2 8.8 10.6 0.7 12.2 8.8 9.7 0.9 11.8 6.5 312 5 300 165 4.4 0.1 4.8 4.3 05/19/2006 00:20:00 10.2 0.7 12.2 8 10.2 0.8 12.2 8 9.6 1 11.5 6.5 312 5 311 165 4.4 0.1 4.8 4 05/19/2006 00:30:00 10 0.7 11.8 7.2 10.1 0.8 11.8 7.6 9.2 0.8 11.1 6.5 312 4 308 165 4.3 0.1 4.5 3.8 05/19/2006 00:40:00 9.7 0.6 11.8 8 9.7 0.6 11.5 8 8.8 1 11.8 6.1 311 5 315 165 4.3 0.2 4.5 3.8 05/19/2006 00:50:00 9.3 0.8 11.5 7.2 9.3 0.8 11.5 6.8 8 1 10.7 4.9 309 5 297 165 4.2 0.2 4.5 3.5 05/19/2006 01:00:00 9.4 0.8 12.2 7.2 9.5 0.8 12.2 7.2 7.9 1 10.7 5.7 307 4 301 165 4.4 0 4.5 3.8 05/19/2006 01:10:00 9.1 0.7 10.7 6.5 9.1 0.7 10.7 6.5 8 1 10.3 4.9 310 5 304 165 4.4 0 4.5 3.8 05/19/2006 01:20:00 8.7 1.1 11.5 6.5 8.7 1.1 11.8 6.1 7.7 1 10.7 5.3 311 6 297 165 4.3 0.1 4.5 3.8 05/19/2006 01:30:00 9.1 0.8 11.1 6.8 9.1 0.8 11.1 6.5 8.7 1 11.8 4.9 313 5 308 165 4.3 0.1 4.5 3.5 05/19/2006 01:40:00 8.5 0.9 11.1 5.7 8.5 1 11.5 5.7 7.3 1.2 10.7 4.9 308 8 317 165 4.1 0 4.3 3.5 05/19/2006 01:50:00 9.3 1.2 12.6 6.1 9.4 1.2 12.6 6.1 7.3 1 10.7 5.3 300 7 300 165 4.1 0.1 4.5 3.8 05/19/2006 02:00:00 9.9 1.2 13 6.8 10 1.2 13 6.8 7.3 1 11.1 4.9 301 5 298 165 4.1 0.1 4.5 3.5 05/19/2006 02:10:00 8.8 0.8 11.1 6.1 8.8 0.8 11.1 6.8 7.1 1 10.7 4.6 305 6 304 165 4 0 4.3 3.8 05/19/2006 02:20:00 9.8 0.7 11.1 7.6 9.9 0.8 11.1 7.2 7.4 0.8 9.5 5.3 305 5 303 165 4 0 4.3 3.8 05/19/2006 02:30:00 9.9 1.2 13 6.8 10 1.2 13 6.8 7.6 1 11.5 5.3 300 6 300 165 4.1 0.2 4.5 3.8 05/19/2006 02:40:00 10.1 0.9 12.2 7.2 10.2 0.9 12.2 7.6 7.6 0.9 10.3 4.9 303 5 297 165 4.2 0.1 4.5 4 05/19/2006 02:50:00 11 0.9 13 8 11.1 0.9 13 8 8.2 0.9 11.1 6.1 304 5 302 165 4.1 0 4.3 4 05/19/2006 03:00:00 11.2 0.9 13 8.8 11.2 1 13 8.8 9 1.1 11.8 6.8 307 5 300 165 4.1 0 4.3 4 05/19/2006 03:10:00 9.5 1 12.2 7.2 9.5 1 12.2 7.2 8.2 1 11.5 6.1 308 6 319 165 4 0 4.3 3.5 05/19/2006 03:20:00 9.3 1 11.5 6.8 9.4 1 11.1 6.8 7.2 0.9 9.9 4.9 302 7 297 165 4.1 0.1 4.5 3.5 05/19/2006 03:30:00 7.8 1.3 10.3 4.2 7.8 1.3 10.7 4.2 6.4 1.1 10.3 4.2 305 9 298 165 4 0 4.3 3.5 05/19/2006 03:40:00 7.1 0.8 8.8 4.9 7.1 0.8 8.8 4.9 5.8 0.7 8.4 4.2 302 7 303 165 4.1 0 4.3 3.8 05/19/2006 03:50:00 7.1 0.9 9.5 4.9 7.1 0.9 9.9 4.9 5.9 0.9 8.8 4.2 302 8 299 165 4.1 0.1 4.5 3.8 05/19/2006 04:00:00 8.7 1 11.1 6.5 8.8 1 11.1 6.1 6.7 1.2 9.9 4.2 295 5 293 165 4.1 0 4.5 3.8 05/19/2006 04:10:00 7.6 1 10.7 5.7 7.6 1 11.1 5.7 6 1.1 9.9 4.2 299 6 292 165 4.3 0.1 4.5 3.8 05/19/2006 04:20:00 6.5 0.9 8.4 4.2 6.5 0.9 8.4 4.2 5.2 0.9 7.6 3.4 295 6 302 165 4.3 0 4.5 3.8 05/19/2006 04:30:00 7.3 0.7 9.1 5.7 7.4 0.7 9.1 5.3 6.2 1 8.8 3.8 290 6 295 165 4.3 0.1 4.5 3.8 05/19/2006 04:40:00 6 1.4 9.1 3.4 6.1 1.4 9.5 3.4 5 1.3 9.1 3 299 8 291 165 4.1 0.1 4.3 3.5 05/19/2006 04:50:00 4.6 0.6 6.1 3 4.7 0.6 6.1 3 4.6 0.5 5.7 3 315 7 318 165 3.8 0 4 3.3 05/19/2006 05:00:00 3.7 0.5 4.9 2.3 3.7 0.6 4.9 2.3 3.7 0.4 4.6 2.6 325 13 344 165 3.7 0.1 4.3 3.3 05/19/2006 05:10:00 3.8 0.5 5.3 2.6 3.8 0.5 5.7 2.6 3.7 0.5 4.9 1.9 314 7 321 165 3.8 0.1 4.3 3.3 05/19/2006 05:20:00 2.2 0.5 3.4 0.7 2.2 0.5 3 0.7 2.5 0.5 3.4 1.1 323 8 341 165 3.8 0.2 4.3 3.3 05/19/2006 05:30:00 2.7 0.7 4.2 1.5 2.7 0.7 4.2 1.5 2.6 0.6 3.8 1.5 299 6 306 165 4.3 0 4.5 3.8 05/19/2006 05:40:00 3.5 0.3 4.6 2.6 3.6 0.3 4.6 3 3.2 0.5 4.6 1.9 298 8 311 165 4.4 0 4.5 4.3 05/19/2006 05:50:00 2.9 0.6 4.6 1.5 3.3 0.6 4.6 1.9 3.3 0.5 4.6 1.9 273 9 283 165 4.5 0.1 4.8 3.8 05/19/2006 06:00:00 2.8 0.5 4.2 1.5 3.4 0.5 4.6 1.9 3.6 0.5 4.6 1.9 268 6 270 165 4.6 0 5 4 05/19/2006 06:10:00 2.4 0.6 3.4 0.7 2.7 0.5 3.8 1.1 2.8 0.4 3.4 1.5 249 8 246 165 5.1 0.1 5.5 4.5 05/19/2006 06:20:00 3.1 0.4 3.8 2.3 3.1 0.4 4.2 2.3 3.3 0.4 4.2 1.9 218 8 224 165 5.1 0.2 5.5 4.5 05/19/2006 06:30:00 2.8 0.4 4.2 2.3 2.7 0.4 3.8 2.3 3 0.3 4.2 2.3 206 4 199 165 5.4 0.2 5.7 4.8 05/19/2006 06:40:00 2.7 0.5 3.8 1.9 2.5 0.5 3.8 1.5 2.8 0.5 3.8 1.9 194 5 198 165 5.7 0.1 6 5.2 05/19/2006 06:50:00 2.9 0.5 4.2 1.9 2.7 0.5 4.2 1.5 3 0.5 4.2 1.9 170 10 162 165 6.2 0.2 6.5 5.5 05/19/2006 07:00:00 3.1 0.4 4.6 1.9 3 0.5 4.2 1.9 3.1 0.5 4.2 1.9 156 9 162 165 6.4 0.2 6.7 5.7 05/19/2006 07:10:00 2.7 0.4 3.8 1.9 2.6 0.5 3.8 1.5 2.8 0.4 3.8 1.9 143 9 145 165 6.2 0.1 6.5 5.7 05/19/2006 07:20:00 3.2 0.5 4.6 2.3 3.2 0.5 4.6 1.9 3.2 0.5 4.2 2.3 150 9 148 165 6.1 0 6.2 5.5 05/19/2006 07:30:00 4.4 0.5 5.7 2.6 4.2 0.4 5.3 2.6 4.3 0.5 5.3 2.6 163 6 153 165 6.1 0 6.2 5.5 05/19/2006 07:40:00 4.9 0.5 6.5 3.4 4.8 0.5 6.1 3.4 4.9 0.5 6.5 3.4 162 7 161 165 6.2 0.1 6.7 5.7 05/19/2006 07:50:00 5 0.6 6.5 3.4 4.9 0.5 6.1 3.4 5.1 0.5 6.5 3.8 168 8 179 165 6.1 0 6.5 6 05/19/2006 08:00:00 5.1 0.6 6.1 3 5 0.6 6.1 3 5.1 0.7 6.1 3 159 4 160 165 6.2 0 6.5 6 05/19/2006 08:10:00 4.8 0.7 6.5 3.4 4.8 0.6 6.5 3.4 5 0.7 6.5 3.4 156 10 168 165 6.2 0.2 6.7 5.7 05/19/2006 08:20:00 4 0.5 5.3 2.6 4 0.5 5.7 2.6 4.2 0.5 5.7 2.6 156 9 160 165 6.5 0 7 6.2 05/19/2006 08:30:00 4 0.5 4.9 2.6 4 0.5 5.3 2.6 4.1 0.5 5.3 3 155 9 147 165 6.7 0.2 7 6 05/19/2006 08:40:00 4 0.5 6.1 2.6 4.1 0.5 5.7 3 4.3 0.5 6.1 3 155 7 159 165 6.7 0.2 7.3 6.2 05/19/2006 08:50:00 4.2 0.5 5.7 2.6 4.2 0.5 5.3 3 4.4 0.5 6.1 3 158 7 150 165 6.4 0 6.7 6 05/19/2006 09:00:00 4.2 0.4 5.3 2.6 4.1 0.4 5.3 3 4.3 0.4 5.3 3.4 148 8 148 165 6.5 0.1 7 6.2 05/19/2006 09:10:00 3.3 0.6 4.6 1.9 3.3 0.6 4.9 1.9 3.4 0.6 4.9 2.3 150 14 141 165 6.6 0 7 6.2 05/19/2006 09:20:00 3.7 0.6 4.9 2.3 3.7 0.6 4.9 2.3 3.8 0.6 5.7 2.6 151 7 154 165 6.3 0 6.5 6 05/19/2006 09:30:00 3.8 0.5 5.7 2.3 3.7 0.5 5.3 2.3 3.9 0.5 5.3 2.6 152 8 138 165 6.2 0 6.2 6 05/19/2006 09:40:00 3.4 0.5 4.6 1.9 3.4 0.5 4.6 1.9 3.5 0.5 4.9 2.6 149 8 140 165 6.4 0 6.7 6 05/19/2006 09:50:00 3.6 0.4 4.9 2.3 3.6 0.4 4.9 2.3 3.7 0.4 4.9 2.3 141 7 139 165 6.5 0 6.7 6.2 05/19/2006 10:00:00 3.4 0.6 5.3 1.5 3.4 0.6 4.9 1.5 3.6 0.7 4.9 1.5 151 11 164 165 6.6 0.1 7 6.2 05/19/2006 10:10:00 3.5 0.6 4.9 2.3 3.6 0.6 4.9 2.3 3.8 0.5 4.9 2.3 155 13 147 165 7.1 0 7.3 7 05/19/2006 10:20:00 3.1 0.5 4.6 1.5 3.2 0.5 4.6 1.9 3.5 0.6 4.9 1.9 158 10 132 165 6.9 0 7.3 6.7 05/19/2006 10:30:00 3.2 0.5 4.9 1.5 3.3 0.5 4.9 1.9 3.4 0.5 4.9 2.3 153 8 140 165 7.3 0.2 7.8 7 05/19/2006 10:40:00 3.5 0.5 5.3 2.3 3.6 0.5 5.3 2.3 3.7 0.5 5.3 2.6 149 8 145 165 7.8 0.2 8.3 7.5 05/19/2006 10:50:00 3.6 0.7 5.3 2.3 3.8 0.7 5.7 2.3 3.8 0.6 5.7 2.3 152 9 168 165 7.9 0.1 8.3 7.5 05/19/2006 11:00:00 4.1 0.5 5.3 3 4.2 0.5 5.7 3 4.3 0.5 5.7 3 151 7 145 165 7.9 0.1 8.3 7.5 05/19/2006 11:10:00 4.5 0.5 6.1 3.4 4.5 0.5 6.1 3 4.5 0.5 6.5 3 153 8 152 165 7.7 0 7.8 7.5 05/19/2006 11:20:00 4.4 0.6 6.1 2.6 4.3 0.6 5.7 2.6 4.4 0.6 6.1 3 158 9 164 165 7.9 0.1 8.3 7.5 05/19/2006 11:30:00 4.8 0.6 6.5 3 4.7 0.5 6.1 3 4.8 0.6 7.2 3.4 161 7 164 165 7.8 0 8 7.5 05/19/2006 11:40:00 5.2 1.1 8.4 2.6 5.1 1.1 8 2.6 5.2 1.1 8.8 2.6 168 13 177 165 7.9 0 8.3 7.5 05/19/2006 11:50:00 7 1.3 9.5 3.4 6.8 1.2 9.1 3.4 7.1 1.2 9.9 3 172 10 166 165 7.8 0.1 8 7.5 05/19/2006 12:00:00 7.7 1 10.3 4.6 7.6 0.9 9.9 4.6 8 1 11.1 5.3 182 9 176 165 7.8 0 8 7.5 05/19/2006 12:10:00 8.5 1 11.1 5.7 8.5 1 11.1 6.1 8.7 1.1 11.5 5.7 187 8 182 165 7.7 0.1 8 7.5 05/19/2006 12:20:00 8 0.7 10.3 6.5 7.9 0.7 9.9 6.1 8.4 0.9 11.8 6.1 184 9 186 165 7.5 0 7.8 7.3 05/19/2006 12:30:00 8.4 0.9 10.7 5.7 8.4 0.9 10.7 6.1 8.7 0.9 11.5 5.7 182 9 191 165 7.3 0.1 7.5 7 05/19/2006 12:40:00 9.1 1 11.5 6.1 9 0.9 11.5 6.1 9.3 1 11.8 6.1 183 7 185 165 7 0 7.3 6.5 05/19/2006 12:50:00 9.4 1.1 11.8 6.5 9.3 1 11.5 6.8 9.5 1 13 6.8 187 8 193 165 6.7 0.2 7 6 05/19/2006 13:00:00 9.3 1 11.8 6.8 9.3 1 11.8 6.8 9.4 1.1 11.8 6.8 186 10 177 165 6.1 0.2 6.7 5.7 05/19/2006 13:10:00 9.5 1 12.2 6.5 9.4 1 12.2 6.5 9.7 1 12.2 7.2 186 6 189 165 5.5 0.1 5.7 5.2 05/19/2006 13:20:00 10.3 1 12.6 7.2 10.2 1 12.2 7.6 10.6 1 13 8 184 7 186 165 5.1 0 5.2 4.8 05/19/2006 13:30:00 9.7 0.8 11.8 7.6 9.6 0.8 11.5 7.2 9.8 0.8 11.8 7.2 179 7 178 165 4.9 0 5.2 4.8 05/19/2006 13:40:00 10.2 0.8 12.2 8 10 0.7 11.8 8 10.3 0.8 12.6 8 179 6 184 165 4.8 0 5.2 4.5 05/19/2006 13:50:00 9.9 1.2 13 7.2 9.7 1.2 12.6 7.2 10.2 1.2 13.3 7.2 177 7 170 165 4.8 0 5 4.5 05/19/2006 14:00:00 9.7 0.8 11.5 7.2 9.5 0.8 11.1 7.2 9.9 0.8 11.8 7.6 172 9 166 165 4.7 0.1 5 4.5 05/19/2006 14:10:00 10.5 0.7 12.2 8.4 10.3 0.6 11.8 8.4 10.6 0.7 12.2 9.1 170 8 166 165 4.7 0.1 5 4.5 05/19/2006 14:20:00 10.6 0.5 11.8 8.4 10.3 0.5 11.5 8.4 10.7 0.6 12.2 8.8 171 4 172 165 4.8 0 5 4.5 05/19/2006 14:30:00 10.9 0.5 11.8 9.1 10.6 0.5 11.8 8.8 11 0.5 12.2 9.1 172 4 168 165 4.8 0 5 4.5 05/19/2006 14:40:00 12.1 0.7 13.3 9.1 11.7 0.6 13 9.1 12.2 0.7 13.7 10.3 171 4 168 165 4.8 0 5 4.5 05/19/2006 14:50:00 12.2 0.5 13.3 10.3 11.8 0.5 13 10.3 12.4 0.6 13.7 9.9 172 4 165 165 4.7 0.1 5 4.3 05/19/2006 15:00:00 12.7 0.6 14.1 11.1 12.4 0.6 13.7 10.7 12.8 0.7 14.1 10.7 169 3 167 165 4.6 0.1 5 4.3 05/19/2006 15:10:00 13.1 0.7 14.5 10.3 12.8 0.7 14.1 10.7 13.2 0.8 14.9 10.7 171 4 176 165 4.5 0.1 4.8 4.3 05/19/2006 15:20:00 13.1 0.6 14.5 11.1 12.8 0.6 14.1 10.7 13.3 0.8 14.9 11.1 168 9 168 165 4.4 0.2 4.8 4.3 05/19/2006 15:30:00 12.9 0.6 14.1 11.1 12.7 0.6 14.1 11.1 13.2 0.7 14.5 11.1 168 5 170 165 4.3 0.2 4.5 3.8 05/19/2006 15:40:00 12.5 0.5 13.7 11.1 12.3 0.5 13.3 10.7 12.8 0.5 14.1 10.7 168 17 165 165 4.2 0.2 4.5 3.5 05/19/2006 15:50:00 12.1 0.6 13.3 10.3 11.9 0.6 13.3 9.9 12.3 0.6 13.7 10.7 167 6 171 165 4.2 0.2 4.5 3.5 05/19/2006 16:00:00 12 0.8 13.7 9.1 11.8 0.8 13.3 9.5 12.2 0.9 14.1 9.5 168 7 165 165 4.1 0.3 4.5 3.5 05/19/2006 16:10:00 12 0.7 13.3 9.9 11.8 0.6 13.3 9.9 12.3 0.6 13.7 10.3 169 9 169 165 4.2 0.2 4.5 3.5 05/19/2006 16:20:00 12.7 0.6 14.1 10.7 12.4 0.6 13.7 10.7 13 0.6 14.1 11.1 170 8 165 165 4.3 0.1 4.5 3.5 05/19/2006 16:30:00 12.8 0.6 14.5 10.7 12.5 0.6 14.1 10.7 13 0.6 14.5 11.1 170 5 167 165 4.3 0 4.5 3.5 05/19/2006 16:40:00 12 0.9 13.7 9.1 11.8 0.9 13.3 9.1 12.1 1 13.7 8.8 169 6 172 165 4.3 0 4.5 3.5 05/19/2006 16:50:00 12 1 14.5 9.5 11.8 1 14.1 9.5 12.2 1.1 14.5 9.5 174 9 184 165 4.3 0 4.5 4.3 05/19/2006 17:00:00 12.4 0.9 14.9 9.9 12.2 0.9 14.5 9.9 12.7 1 15.6 10.3 167 8 177 165 4.3 0 4.5 4.3 05/19/2006 17:10:00 12.7 1.1 16.1 9.5 12.5 1.1 16.1 9.5 12.9 1.2 15.6 9.5 166 13 165 165 4.3 0 4.5 4.3 05/19/2006 17:20:00 14.1 0.9 16.4 10.7 13.9 0.9 16.1 11.1 14.2 1 16.4 11.1 167 10 176 165 4.3 0 4.5 4.3 05/19/2006 17:30:00 15.3 1 17.6 12.6 15 1 17.2 12.2 15.4 1.2 17.9 12.2 168 13 166 165 4.3 0 4.5 4 05/19/2006 17:40:00 14.8 1 17.6 11.8 14.5 1 17.2 11.8 14.9 1 17.6 12.6 171 6 177 165 4.2 0 4.5 3.8 05/19/2006 17:50:00 13.8 1.1 16.8 11.5 13.5 1 16.4 11.1 13.9 1 17.2 10.7 169 4 173 165 4.2 0 4.5 3.8 05/19/2006 18:00:00 12.8 1.1 15.6 9.5 12.7 1 15.3 10.3 12.9 1.1 15.6 9.5 168 12 170 165 4.3 0 4.5 4 05/19/2006 18:10:00 11.3 0.8 13 8 11.1 0.8 13 8 11.3 0.9 13.3 7.6 166 11 162 165 4.4 0 4.5 4.3 05/19/2006 18:20:00 11.6 0.8 14.1 9.1 11.3 0.8 13.7 9.1 11.7 0.8 13.7 9.5 167 5 165 165 4.4 0 4.8 4 05/19/2006 18:30:00 12 1 14.5 9.5 11.8 0.9 14.1 9.5 12.1 1 14.1 9.5 166 11 171 165 4.4 0 4.8 4.3 05/19/2006 18:40:00 12.6 0.7 14.5 11.1 12.5 0.7 14.5 10.7 12.8 0.7 14.5 10.7 164 13 163 165 4.4 0 4.8 4.3 05/19/2006 18:50:00 11.8 1 13.7 9.5 11.6 1 13.7 9.5 12 1 14.1 9.1 167 7 165 165 4.6 0.1 4.8 4.3 05/19/2006 19:00:00 11.8 0.6 13.3 10.7 11.6 0.6 13 9.9 12 0.6 13.7 10.3 165 18 157 165 4.6 0 4.8 4.3 05/19/2006 19:10:00 12.5 0.7 14.1 9.9 12.3 0.6 13.7 10.3 12.5 0.7 14.1 10.7 163 5 164 165 4.6 0 4.8 4.3 05/19/2006 19:20:00 12.8 0.8 14.5 10.7 12.6 0.7 14.1 10.3 12.8 0.8 14.5 10.7 165 11 165 165 4.7 0 5 4.5 05/19/2006 19:30:00 12.9 0.6 14.5 10.7 12.7 0.6 14.5 10.7 13 0.7 14.5 9.9 166 11 165 165 4.9 0 5 4.5 05/19/2006 19:40:00 12.3 0.6 13.7 10.7 12.2 0.6 13.7 10.3 12.5 0.7 14.1 10.3 163 15 165 165 4.9 0 5 4.8 05/19/2006 19:50:00 12.2 0.6 14.1 10.3 12 0.6 13.3 10.3 12.3 0.6 13.7 10.7 162 9 162 165 4.9 0 5 4.8 05/19/2006 20:00:00 11.8 0.6 13 10.3 11.6 0.5 13 10.3 11.9 0.6 13.7 10.3 164 10 162 165 4.9 0 5.2 4.8 05/19/2006 20:10:00 10.7 0.8 12.2 8.8 10.5 0.7 12.2 8.8 10.8 0.8 12.6 8.4 163 17 160 165 4.9 0 5 4.8 05/19/2006 20:20:00 9.5 1.3 12.2 6.5 9.4 1.3 11.8 6.5 9.6 1.4 12.6 6.5 161 9 173 165 5 0 5 4.8 05/19/2006 20:30:00 10 1 13 8 9.7 1 12.2 8 10 0.9 12.6 8 160 6 162 165 4.9 0 5 4.8 05/19/2006 20:40:00 9.2 0.8 11.5 7.2 9.1 0.8 11.5 7.2 9.4 0.9 11.8 6.8 161 7 169 165 4.9 0 5 4.8 05/19/2006 20:50:00 8.8 1 11.5 6.8 8.7 1 11.5 6.5 8.9 0.9 11.8 6.5 162 8 171 165 5 0 5.2 4.8 05/19/2006 21:00:00 9.5 0.9 12.2 7.2 9.4 0.9 11.8 7.6 9.5 0.9 11.8 7.6 163 7 171 165 5.1 0 5.2 4.8 05/19/2006 21:10:00 8.9 0.8 10.7 6.8 8.7 0.8 10.7 6.8 9.1 0.9 11.1 6.8 164 9 165 165 5.2 0 5.2 5 05/19/2006 21:20:00 9 0.7 10.7 7.2 8.9 0.6 10.7 7.2 9.1 0.7 11.1 7.2 163 4 159 165 5.2 0 5.5 4.8 05/19/2006 21:30:00 8.9 0.6 10.7 7.6 8.7 0.6 10.3 7.2 8.9 0.7 10.7 7.2 162 12 164 165 5.2 0 5.5 5 05/19/2006 21:40:00 8.4 0.8 10.7 6.5 8.3 0.8 10.7 6.5 8.5 0.7 10.7 6.8 161 6 154 165 5.2 0.1 5.5 5 05/19/2006 21:50:00 8.9 0.7 10.7 6.8 8.7 0.7 10.3 6.8 8.9 0.8 10.7 6.8 164 12 164 165 5.2 0.1 5.5 5 05/19/2006 22:00:00 8.6 0.9 10.7 5.7 8.4 0.9 10.3 5.7 8.6 0.9 10.3 5.7 163 11 159 165 5.2 0 5.7 5 05/19/2006 22:10:00 7.8 1.1 10.3 5.3 7.7 1 9.9 5.3 8 1 10.3 5.7 162 9 147 165 5.3 0 5.5 5 05/19/2006 22:20:00 7.7 0.7 9.5 5.3 7.6 0.7 9.1 5.7 7.9 0.6 9.5 6.1 161 12 165 165 5.4 0 5.7 5 05/19/2006 22:30:00 7 0.7 8.4 4.9 6.9 0.7 8 5.3 7.2 0.8 9.1 4.9 166 7 165 165 5.4 0 5.7 5 05/19/2006 22:40:00 6 0.5 7.6 4.9 5.9 0.5 7.2 4.6 6.1 0.5 7.6 4.6 163 10 167 165 5.4 0 5.7 5 05/19/2006 22:50:00 5.6 0.6 7.2 3.8 5.5 0.6 7.2 3.8 5.6 0.7 7.2 3.8 163 6 153 165 5.4 0 5.7 5 05/19/2006 23:00:00 6.1 0.4 6.8 4.6 5.9 0.4 6.8 4.9 6.3 0.4 7.6 4.9 166 10 161 165 5.4 0 5.7 5 05/19/2006 23:10:00 5.7 0.4 6.5 4.6 5.5 0.4 6.5 4.6 5.9 0.4 6.8 4.9 167 4 167 165 5.5 0 5.7 5 05/19/2006 23:20:00 5 0.5 6.5 4.2 4.9 0.5 5.7 3.8 5.4 0.4 6.5 4.6 167 4 171 165 5.5 0 5.7 5.2 05/19/2006 23:30:00 3.5 0.4 4.6 2.3 3.4 0.4 4.2 2.6 3.9 0.4 4.9 2.6 167 6 170 165 5.4 0 5.7 5 05/19/2006 23:40:00 4 0.8 5.7 3 3.8 0.7 5.3 2.6 4.4 0.7 5.7 3 171 4 166 165 5.4 0 5.7 5 05/19/2006 23:50:00 5 0.4 5.7 3.4 4.9 0.4 5.7 3.4 5.3 0.5 6.1 3.8 172 3 167 165 5.4 0 5.5 5 05/20/2006 00:00:00 3.1 0.4 4.6 2.3 3.1 0.4 4.6 2.3 3.3 0.3 4.2 2.6 182 4 179 165 5.2 0.1 5.5 4.5 05/20/2006 00:10:00 4.1 0.4 4.9 3 4.1 0.4 4.6 3 4.4 0.5 4.9 3.4 180 2 181 165 4.9 0 5 4.3 05/20/2006 00:20:00 4.9 0.3 6.1 4.2 4.9 0.3 5.7 4.2 5.2 0.3 5.7 4.6 182 2 183 165 4.8 0.1 5 4.3 05/20/2006 00:30:00 5.7 0.3 6.5 4.6 5.7 0.3 6.5 4.9 5.9 0.4 6.8 4.6 183 2 185 165 4.9 0 5 4.3 05/20/2006 00:40:00 6 0.4 6.8 4.6 6.1 0.5 6.8 4.6 6.3 0.5 7.2 4.9 190 3 192 165 4.9 0 5 4.3 05/20/2006 00:50:00 6.2 0.3 6.8 5.7 6.3 0.3 6.8 5.7 6.5 0.3 7.2 5.7 191 2 188 165 4.9 0 5 4.3 05/20/2006 01:00:00 6.6 0.2 7.2 6.1 6.6 0.2 7.2 6.1 7.1 0.3 7.6 6.5 188 3 191 165 4.9 0 5.2 4.3 05/20/2006 01:10:00 5.8 0.3 6.5 5.3 5.9 0.3 6.5 5.3 6.1 0.3 6.8 4.9 191 1 192 165 5 0.1 5.2 4.3 05/20/2006 01:20:00 5.4 0.3 6.1 4.6 5.4 0.3 6.1 4.9 5.7 0.4 6.8 4.9 190 2 189 165 5 0 5 4.3 05/20/2006 01:30:00 5.6 0.4 6.1 4.6 5.5 0.4 6.1 4.6 6.1 0.4 6.8 4.9 187 1 187 165 4.9 0 5 4.3 05/20/2006 01:40:00 5.2 0.2 5.7 4.9 5.1 0.2 5.7 4.6 5.5 0.2 6.1 4.9 187 2 190 165 4.9 0 5 4.8 05/20/2006 01:50:00 5 0.2 5.7 4.6 4.9 0.2 5.3 4.6 5.5 0.2 6.1 4.9 182 2 183 165 4.8 0 5 4.8 05/20/2006 02:00:00 4.9 0.2 5.3 4.6 4.7 0.2 5.3 4.2 5 0.2 5.7 4.6 178 2 175 165 4.9 0 5 4.8 05/20/2006 02:10:00 5 0.3 5.7 4.6 4.8 0.3 5.3 4.2 4.8 0.4 5.7 4.2 178 2 177 165 4.9 0 5 4.8 05/20/2006 02:20:00 4.9 0.4 5.7 4.2 4.7 0.4 5.3 3.8 4.7 0.6 5.7 3.8 171 4 178 165 5 0 5.2 4.8 05/20/2006 02:30:00 4.6 0.6 5.7 3.4 4.4 0.6 5.3 3.4 4.4 0.6 5.7 3.4 165 6 165 165 4.9 0 5 4.8 05/20/2006 02:40:00 4.4 0.4 5.3 3.4 4.2 0.4 4.9 3.4 4.1 0.4 4.9 3.4 159 9 162 165 4.8 0 5 4.3 05/20/2006 02:50:00 4.7 0.3 5.7 3.4 4.5 0.3 5.3 3.4 4.4 0.4 5.3 3.8 159 3 164 165 4.9 0 5.2 4.3 05/20/2006 03:00:00 4.5 0.3 4.9 3.4 4.4 0.3 4.9 3.4 4.4 0.3 4.9 3.4 152 5 157 165 5 0 5.2 4.5 05/20/2006 03:10:00 3.7 0.5 4.9 2.6 3.6 0.5 4.6 2.6 3.8 0.4 4.6 2.6 155 6 153 165 4.9 0 5 4.5 05/20/2006 03:20:00 3.2 0.3 4.2 2.3 3.1 0.3 3.8 2.3 3.4 0.3 4.2 2.3 157 4 162 165 5 0 5.2 4.5 05/20/2006 03:30:00 2.9 0.6 4.2 1.5 2.8 0.6 4.2 1.1 3.4 0.6 4.6 1.9 164 7 175 165 5 0.1 5.2 4.5 05/20/2006 03:40:00 1.9 0.3 3 1.1 1.9 0.4 3 1.1 2.1 0.4 3 1.1 162 2 156 165 5 0 5 4.5 05/20/2006 03:50:00 1.7 0.3 2.3 0.7 1.7 0.3 2.3 0.7 2.1 0.3 2.6 1.5 160 4 161 165 5.1 0.1 5.5 4.8 05/20/2006 04:00:00 2.2 0.5 3 1.1 2.3 0.5 3.4 1.1 2.6 0.3 3.4 1.5 148 11 154 165 5.2 0.2 5.5 4.5 05/20/2006 04:10:00 1.8 0.5 2.6 0.7 1.9 0.5 3 0.4 2.2 0.3 3 1.5 143 7 127 165 5.1 0.2 5.2 4.5 05/20/2006 04:20:00 0.5 0.4 1.9 0.4 0.5 0.4 1.9 0.4 0.7 0.6 2.3 0.4 152 0 153 165 5.1 0.2 5.5 4.5 05/20/2006 04:30:00 1.7 0.4 2.3 0.7 1.6 0.4 2.3 0.7 2.3 0.4 3 1.5 46 82 153 165 5.3 0 5.5 4.8 05/20/2006 04:40:00 1.8 0.2 2.3 1.1 1.3 0.6 2.3 0.4 2.4 0.2 2.6 1.9 356 10 346 165 5.3 0 5.5 4.8 05/20/2006 04:50:00 3.1 0.4 3.8 1.9 2 0.8 3.8 0.4 3.5 0.4 4.2 2.6 359 9 7 165 5.2 0.1 5.5 4.8 05/20/2006 05:00:00 2.5 0.7 3.4 0.4 1.7 0.7 3.4 0.4 2.8 0.7 3.8 1.1 4 9 346 165 5.1 0 5.2 4.5 05/20/2006 05:10:00 1.7 0.4 2.6 0.4 1.5 0.7 2.6 0.4 1.9 0.3 2.6 1.1 23 12 23 165 4.9 0 5 4.5 05/20/2006 05:20:00 3.4 0.9 4.6 1.5 2.7 1.1 4.2 0.4 3.7 0.8 4.9 1.5 11 7 18 165 4.9 0 5 4.5 05/20/2006 05:30:00 3.3 0.4 4.6 1.9 2.5 0.6 3.8 1.1 3.5 0.4 4.6 2.6 1 12 355 165 4.9 0 5 4.5 05/20/2006 05:40:00 2.5 0.5 4.2 1.5 1.8 0.8 3.4 0.4 2.8 0.5 3.8 1.5 354 10 350 165 4.9 0 5 4.5 05/20/2006 05:50:00 0.9 0.5 1.9 0.4 0.5 0.3 1.9 0.4 1.6 0.5 2.6 0.4 347 23 10 165 4.9 0 5 4.5 05/20/2006 06:00:00 0.5 0.2 1.5 0.4 0.4 0.2 1.5 0.4 0.7 0.3 1.5 0.4 288 7 281 165 5.1 0.2 5.2 4.5 05/20/2006 06:10:00 1.1 0.6 2.3 0.4 1.1 0.7 2.3 0.4 1.2 0.4 2.3 0.4 288 5 288 165 5.1 0.1 5.2 4.5 05/20/2006 06:20:00 2.1 0.5 3.4 1.1 2.2 0.5 3.4 1.1 2 0.7 3.4 0.7 306 9 311 165 5.1 0.1 5.2 4.5 05/20/2006 06:30:00 1.9 0.4 3 1.1 1.8 0.4 3 0.4 2.3 0.3 3 1.5 334 9 326 165 5.2 0.2 5.2 4.5 05/20/2006 06:40:00 0.8 0.5 1.9 0.4 0.5 0.4 1.9 0.4 1 0.5 2.3 0.4 357 12 336 165 5.1 0.3 5.5 4.5 05/20/2006 06:50:00 0.4 0.1 0.7 0.4 0.4 0 0.4 0.4 0.4 0.1 1.1 0.4 78 45 48 165 5.1 0.2 5.5 4.5 05/20/2006 07:00:00 0.8 0.4 1.5 0.4 0.7 0.4 1.5 0.4 1 0.6 2.3 0.4 258 36 281 165 5.1 0.2 5.5 4.5 05/20/2006 07:10:00 0.6 0.4 2.3 0.4 0.5 0.4 2.3 0.4 1.3 0.4 2.3 0.4 280 12 289 165 5.1 0.1 5.5 4.8 05/20/2006 07:20:00 1.1 0.7 2.3 0.4 1.1 0.7 2.6 0.4 1.6 0.5 3 0.7 285 8 291 165 5.2 0.1 5.5 4.8 05/20/2006 07:30:00 3.2 0.6 4.6 1.9 3.3 0.6 4.9 1.5 2.8 0.6 4.2 1.5 295 6 294 165 5.1 0.1 5.5 4.8 05/20/2006 07:40:00 4 0.4 4.9 3 4.1 0.4 5.3 3 3 0.4 4.2 1.9 296 4 290 165 5.1 0.2 5.5 4.8 05/20/2006 07:50:00 3.8 0.6 5.3 2.3 3.9 0.6 5.3 2.3 2.9 0.5 4.2 1.9 301 5 298 165 5.2 0.2 5.5 4.8 05/20/2006 08:00:00 3.6 0.6 4.9 2.3 3.6 0.6 4.9 2.3 3.2 0.5 4.6 1.9 311 6 304 165 5.4 0 5.7 5 05/20/2006 08:10:00 2 1 3.8 0.7 1.7 1.3 4.2 0.4 2.2 0.7 4.2 1.1 334 16 314 165 5.7 0.2 6 5 05/20/2006 08:20:00 0.5 0.2 1.5 0.4 0.4 0 0.7 0.4 0.8 0.3 1.5 0.4 359 4 2 165 6.2 0.1 6.5 5.7 05/20/2006 08:30:00 0.4 0 0.7 0.4 0.4 0 0.4 0.4 0.4 0.2 1.5 0.4 356 22 266 165 6.6 0.2 7 6 05/20/2006 08:40:00 0.9 0.5 2.3 0.4 0.9 0.5 1.9 0.4 1.2 0.5 2.3 0.4 286 19 302 165 6.7 0.1 7.3 6.2 05/20/2006 08:50:00 1.2 0.5 2.3 0.4 1.1 0.6 2.6 0.4 1.6 0.4 2.3 0.7 301 11 310 165 6.2 0 6.7 6 05/20/2006 09:00:00 0.5 0.3 1.9 0.4 0.5 0.3 1.9 0.4 0.7 0.4 2.3 0.4 297 4 299 165 6.3 0 6.5 6 05/20/2006 09:10:00 0.5 0.2 1.1 0.4 0.5 0.3 1.5 0.4 1.2 0.3 1.9 0.4 266 9 274 165 6.4 0 6.7 6 05/20/2006 09:20:00 0.7 0.3 1.5 0.4 0.7 0.4 1.9 0.4 1.5 0.3 2.3 0.7 261 10 243 165 6.3 0.1 6.7 6 05/20/2006 09:30:00 1.1 0.5 2.3 0.4 1.1 0.5 2.3 0.4 1.7 0.3 2.6 1.1 235 20 244 165 6.7 0.1 7 6 05/20/2006 09:40:00 0.8 0.4 1.9 0.4 0.8 0.5 1.9 0.4 1.4 0.4 2.3 0.4 259 15 243 165 6.7 0.1 7 6.2 05/20/2006 09:50:00 0.8 0.5 2.3 0.4 0.7 0.5 2.3 0.4 1.1 0.7 2.6 0.4 252 22 237 165 6.9 0 7.3 6.2 05/20/2006 10:00:00 0.6 0.4 1.9 0.4 0.6 0.4 2.3 0.4 0.7 0.5 2.3 0.4 279 32 276 165 6.8 0 7 6.2 05/20/2006 10:10:00 1.4 0.5 2.6 0.4 1.9 0.6 3.4 0.4 2 0.5 3 0.7 260 12 253 165 6.9 0 7.3 6.7 05/20/2006 10:20:00 0.9 0.5 2.3 0.4 1 0.7 2.6 0.4 1.2 0.6 2.6 0.4 274 26 277 165 7.3 0.1 7.8 7 05/20/2006 10:30:00 0.9 0.6 2.6 0.4 0.9 0.7 3 0.4 1 0.7 2.6 0.4 256 45 239 165 7.4 0.2 7.8 6.7 05/20/2006 10:40:00 1 0.6 2.6 0.4 0.9 0.6 2.6 0.4 1.1 0.6 2.6 0.4 325 107 231 165 7.1 0 7.8 6.7 05/20/2006 10:50:00 1.3 0.8 3 0.4 1.4 0.8 3 0.4 1.5 0.8 3 0.4 258 66 284 165 7 0.3 7.8 6.2 05/20/2006 11:00:00 1.4 0.7 3 0.4 1.3 0.8 2.6 0.4 1.5 0.7 2.6 0.4 314 21 312 165 8 0.2 8.5 7.3 05/20/2006 11:10:00 1.1 0.7 2.6 0.4 0.9 0.6 2.6 0.4 1.1 0.6 2.3 0.4 22 58 18 165 7.9 0.1 8.3 7.5 05/20/2006 11:20:00 2.1 0.5 3.4 1.1 1.8 0.7 3.4 0.4 2.1 0.6 3.4 0.7 25 11 15 165 7.6 0 8 7 05/20/2006 11:30:00 1.9 0.7 3.4 0.4 1.7 0.8 3.4 0.4 2.2 0.6 3.8 0.7 36 10 17 165 7.4 0.2 8 7 05/20/2006 11:40:00 1.9 0.4 3 1.1 1.8 0.4 3.4 0.4 2 0.5 3 0.4 44 11 36 165 7.5 0.2 8 7 05/20/2006 11:50:00 1.2 0.6 3 0.4 1 0.6 3.4 0.4 1.3 0.6 2.6 0.4 45 47 30 165 8.1 0 8.5 8 05/20/2006 12:00:00 0.4 0.2 1.5 0.4 0.4 0.1 1.1 0.4 0.5 0.2 1.5 0.4 51 41 128 165 8.1 0.1 8.5 7.8 05/20/2006 12:10:00 1.3 0.5 2.3 0.4 1.2 0.6 2.6 0.4 1.6 0.5 2.6 0.4 115 17 111 165 7.3 0.4 8 6.7 05/20/2006 12:20:00 1.7 0.7 3.4 0.4 1.5 0.8 3.4 0.4 2 0.6 3.4 0.7 112 16 123 165 6.7 0 7 6.2 05/20/2006 12:30:00 1.4 0.6 2.6 0.4 1.2 0.6 2.6 0.4 1.8 0.4 3 0.4 114 21 116 165 6.8 0 7 6.7 05/20/2006 12:40:00 1.8 1.2 4.2 0.4 1.7 1.2 4.2 0.4 2 1 3.8 0.4 73 29 52 165 7 0.1 7.3 6.7 05/20/2006 12:50:00 2 0.7 3.8 0.4 1.9 0.7 3.4 0.4 1.9 0.6 3.4 0.7 60 20 49 165 7.3 0 7.5 7 05/20/2006 13:00:00 1.6 0.5 2.6 0.4 1.7 0.5 2.6 0.4 1.9 0.5 2.6 0.4 99 15 57 165 7.1 0.1 7.3 6.5 05/20/2006 13:10:00 1.2 0.5 2.6 0.4 1.5 0.5 2.6 0.4 1.7 0.5 2.6 0.4 83 17 94 165 6.9 0.1 7.3 6.2 05/20/2006 13:20:00 1.3 0.6 2.6 0.4 1.3 0.6 2.6 0.4 1.5 0.5 2.6 0.4 45 36 32 165 7.3 0.2 7.5 7 05/20/2006 13:30:00 2.2 0.4 3 1.1 2.2 0.5 3.4 0.4 2.5 0.4 3.4 1.5 21 11 23 165 7.4 0.1 7.8 7 05/20/2006 13:40:00 2 0.5 3 1.1 1.9 0.6 3 0.4 2.3 0.5 3.4 1.1 10 14 31 165 7.4 0.1 7.8 7 05/20/2006 13:50:00 0.6 0.4 1.9 0.4 0.6 0.3 1.9 0.4 0.8 0.5 1.9 0.4 349 28 37 165 7.8 0.1 8 7.3 05/20/2006 14:00:00 1 0.6 2.6 0.4 1 0.6 3 0.4 1.3 0.7 3 0.4 25 51 33 165 8 0 8.3 7.8 05/20/2006 14:10:00 2 0.5 3.4 0.7 1.7 0.6 3.4 0.4 2.2 0.4 3.4 1.1 356 9 355 165 8 0.1 8.3 7.8 05/20/2006 14:20:00 1.2 0.6 2.6 0.4 1 0.6 2.6 0.4 1.3 0.7 2.6 0.4 14 23 14 165 8 0 8.3 7.8 05/20/2006 14:30:00 0.8 0.5 2.3 0.4 0.9 0.5 2.3 0.4 1.4 0.6 2.6 0.4 130 30 141 165 7.4 0.4 8.3 6.7 05/20/2006 14:40:00 0.9 0.5 2.3 0.4 1 0.5 2.3 0.4 1.6 0.4 2.3 0.7 142 12 129 165 6.6 0.1 7 6 05/20/2006 14:50:00 0.6 0.3 1.5 0.4 0.8 0.4 1.9 0.4 1.3 0.3 2.3 0.4 124 8 130 165 6.6 0 7 6 05/20/2006 15:00:00 1.3 0.4 2.3 0.4 1.6 0.4 2.6 0.4 1.9 0.4 2.6 1.1 119 9 122 165 6.7 0.1 7 6.2 05/20/2006 15:10:00 0.7 0.3 1.5 0.4 1 0.4 1.9 0.4 1.5 0.4 2.3 0.7 103 8 110 165 6.7 0.1 7 6.2 05/20/2006 15:20:00 0.8 0.5 2.3 0.4 1.2 0.6 2.6 0.4 1.5 0.4 2.3 0.4 107 13 111 165 6.7 0.1 7 6.2 05/20/2006 15:30:00 1.4 0.7 3 0.4 1.7 0.6 3 0.4 1.8 0.5 2.6 0.4 57 30 31 165 6.9 0.1 7 6.2 05/20/2006 15:40:00 2.3 0.4 3 0.7 2.4 0.4 3.4 1.1 2.5 0.4 3.4 1.1 35 8 28 165 6.7 0 7 6.5 05/20/2006 15:50:00 3.5 0.5 5.3 2.3 3.6 0.5 5.3 2.6 3.6 0.6 4.9 2.3 32 7 25 165 6.6 0 6.7 6.2 05/20/2006 16:00:00 4.4 0.4 5.3 2.3 4.6 0.4 5.3 2.6 4.5 0.5 5.7 3 34 4 35 165 6.2 0 6.5 6 05/20/2006 16:10:00 4 0.6 5.3 2.6 4.1 0.6 5.3 2.6 4 0.6 5.3 2.3 26 7 26 165 6.2 0.1 6.2 6 05/20/2006 16:20:00 4.8 0.5 5.7 3 4.7 0.6 5.7 2.6 4.8 0.5 5.7 3.8 23 6 26 165 6.1 0 6.2 5.7 05/20/2006 16:30:00 4.8 0.6 5.7 3.4 4.7 0.7 6.1 2.6 4.8 0.6 6.1 3.4 22 7 21 165 6.2 0 6.2 6 05/20/2006 16:40:00 5.1 0.6 6.5 3.4 4.9 0.7 6.5 3 5 0.7 6.1 3.4 21 7 25 165 6.2 0 6.7 6 05/20/2006 16:50:00 5.8 0.5 6.8 3.8 5.7 0.6 6.8 3.8 5.7 0.6 7.2 3.8 24 5 23 165 6.1 0 6.5 5.7 05/20/2006 17:00:00 5.9 0.6 6.8 3.8 5.7 0.7 6.8 2.6 5.9 0.6 7.2 3.8 20 6 22 165 5.9 0 6.2 5.7 05/20/2006 17:10:00 6 0.7 7.2 3.8 5.9 0.8 7.2 3.4 6 0.7 7.2 4.2 21 5 19 165 5.8 0.1 6 5.5 05/20/2006 17:20:00 6 0.6 7.2 4.2 5.9 0.6 6.8 4.2 5.9 0.6 7.2 3.8 22 5 19 165 5.7 0.1 6 5.5 05/20/2006 17:30:00 5.8 0.6 7.2 4.2 5.6 0.7 6.8 3.4 5.5 0.7 6.8 3.8 21 6 12 165 5.8 0.1 6 5.5 05/20/2006 17:40:00 6.9 0.6 8.8 5.3 6.6 0.8 8.8 4.6 6.7 0.7 8.4 4.9 21 5 22 165 5.7 0.2 6.2 5.5 05/20/2006 17:50:00 7.7 0.5 9.1 6.1 7.4 0.6 9.1 4.9 7.7 0.6 9.1 5.3 19 4 22 165 5.6 0.2 6.2 5.2 05/20/2006 18:00:00 8 0.5 9.5 6.5 7.6 0.6 9.5 4.9 7.9 0.6 9.5 6.1 17 3 22 165 5.6 0.2 6 5.2 05/20/2006 18:10:00 7.4 0.5 8.4 5.7 6.7 0.8 8.4 3.4 7.4 0.6 8.8 4.9 15 4 17 165 5.6 0.2 6 5 05/20/2006 18:20:00 7.5 0.6 9.1 5.3 7.3 0.8 9.1 4.6 7.2 0.8 9.1 4.9 21 5 40 165 5.6 0.2 5.7 5.2 05/20/2006 18:30:00 7.4 0.5 8.8 6.1 6.7 1 8.8 3.8 7.4 0.6 8.8 5.7 15 6 18 165 5.5 0.2 5.7 5.2 05/20/2006 18:40:00 7.2 0.7 8.8 4.9 6.3 1 8.4 3.4 7.2 0.8 8.8 4.6 13 6 19 165 5.6 0.2 6 5.2 05/20/2006 18:50:00 6.2 0.7 8 4.2 5.4 1 7.2 3 6.2 0.6 7.6 4.6 13 7 22 165 5.7 0.2 6 5.2 05/20/2006 19:00:00 6.7 0.8 8.8 4.6 5.3 1.1 8.4 2.6 6.5 0.7 8.8 4.9 10 6 20 165 5.6 0.2 6.2 5.2 05/20/2006 19:10:00 7.6 1 9.9 4.9 6.6 1.4 9.5 2.6 7.3 1 9.5 4.6 13 8 4 165 5.6 0.3 6 5.2 05/20/2006 19:20:00 7.5 0.8 9.5 5.7 6.5 1.1 9.5 3.4 7.4 0.7 9.1 5.3 13 5 25 165 5.6 0.3 5.7 5.2 05/20/2006 19:30:00 7.3 1.1 10.7 4.9 6.3 1.6 10.7 3 7.2 1.1 10.7 4.9 13 8 19 165 5.6 0.3 5.7 5 05/20/2006 19:40:00 7.2 1 9.5 4.9 5.8 1.5 9.1 3 7.1 1.1 9.9 4.9 9 8 25 165 5.6 0.3 6 5 05/20/2006 19:50:00 7.4 1 9.5 4.9 5.6 1.3 9.5 2.6 7.2 1 9.9 5.3 7 6 19 165 5.6 0.3 5.7 5 05/20/2006 20:00:00 7.1 0.9 10.3 4.2 5.3 0.9 8 3 6.9 0.9 10.3 4.2 3 7 9 165 5.7 0.2 6 5 05/20/2006 20:10:00 8.4 1 11.1 5.7 6.3 1.2 9.9 3.8 8.1 1.1 11.1 5.3 1 8 356 165 5.7 0.2 6 5 05/20/2006 20:20:00 8.4 1.2 12.2 5.7 6.5 1.5 10.3 3.4 7.9 1.2 11.8 5.3 359 7 10 165 5.7 0.1 5.7 5 05/20/2006 20:30:00 10.3 1.3 14.1 7.2 7.9 1.5 12.2 4.9 9.9 1.6 14.9 6.1 360 8 9 165 5.7 0 5.7 5.2 05/20/2006 20:40:00 10.7 1.2 13.3 7.6 7.9 1.3 12.6 4.9 10.5 1.3 13 7.6 1 7 3 165 5.7 0 5.7 5.5 05/20/2006 20:50:00 10.6 1.1 13.7 6.5 8 1.7 13 4.6 10.3 1.2 13.3 6.1 0 8 11 165 5.7 0 5.7 5.5 05/20/2006 21:00:00 11 1.2 14.1 8 8.4 1.6 14.1 4.9 10.8 1.2 13.7 7.2 1 8 16 165 5.6 0 5.7 5.5 05/20/2006 21:10:00 10.6 1.3 14.5 5.7 7.8 1.7 14.5 3.8 10.3 1.3 14.5 6.5 2 7 13 165 5.5 0 5.7 5.2 05/20/2006 21:20:00 12.4 1.8 16.1 8.4 9.8 2 15.3 5.7 12.2 1.7 16.1 5.7 6 9 15 165 5.3 0 5.5 5 05/20/2006 21:30:00 13.5 1.8 18.7 8 10.9 2.6 19.5 6.8 13.1 1.8 18.3 8 1 11 349 165 5.2 0 5.5 5 05/20/2006 21:40:00 13.1 1.6 18.3 9.9 10.3 2 17.6 6.5 12.8 1.4 17.2 9.1 360 9 9 165 5.1 0.1 5.2 4.8 05/20/2006 21:50:00 12.9 2.2 18.3 8.8 10.7 2.6 17.2 4.9 12.4 2.2 17.9 7.6 359 11 356 165 4.9 0.1 5.2 4.5 05/20/2006 22:00:00 13.2 2.8 22.1 6.1 10.8 2.5 17.6 4.6 12.7 2.7 22.1 6.5 356 9 360 165 4.9 0 5.5 4.5 05/20/2006 22:10:00 13.6 2.2 19.9 7.6 10.9 2.4 18.3 6.1 13.1 2.1 17.9 7.6 357 9 358 165 4.8 0.1 5 4.3 05/20/2006 22:20:00 13.4 1.7 18.3 8.8 11 2.4 19.1 6.8 12.8 1.9 17.6 8 358 9 344 165 4.6 0.2 5 4.3 05/20/2006 22:30:00 13 1.5 16.8 9.1 10.4 2 15.3 6.1 12.6 1.5 17.2 8.8 3 9 6 165 4.6 0.1 4.8 4.3 05/20/2006 22:40:00 13.5 1.9 18.3 9.1 10.6 2.1 16.8 6.5 13.1 2.1 18.7 8 0 9 2 165 4.6 0.1 4.8 4 05/20/2006 22:50:00 12 1.6 16.1 8.4 9.6 2.1 16.8 5.7 11.7 1.7 17.2 7.2 1 10 6 165 4.6 0.1 4.8 4.3 05/20/2006 23:00:00 13.1 1.8 19.1 9.5 10.1 2.4 17.2 6.1 12.9 1.7 17.2 9.9 4 9 6 165 4.5 0.1 5 4 05/20/2006 23:10:00 14.1 1.9 20.6 9.9 10.7 2.2 20.2 6.5 13.8 2.1 19.5 9.1 6 8 18 165 4.4 0 4.5 4 05/20/2006 23:20:00 12.1 1.4 16.8 7.6 9.8 2 14.9 6.1 11.7 1.4 15.6 7.2 357 8 352 165 4.4 0 4.5 4 05/20/2006 23:30:00 11.7 1.1 15.3 8.8 8.7 1.4 13 6.1 11.4 1.2 15.3 6.8 2 8 7 165 4.3 0 4.5 3.8 05/20/2006 23:40:00 13.5 1.7 18.3 9.5 10.3 1.7 14.9 6.8 13 2 21 8.8 360 9 3 165 4.3 0 4.5 3.8 05/20/2006 23:50:00 13.4 1.5 18.7 8.8 11.8 2.3 18.7 8 12.7 1.6 17.9 8.4 352 8 338 165 4.2 0 4.5 4.3 05/21/2006 00:00:00 13.4 1.7 17.6 8.4 10.7 2.1 15.6 6.8 12.9 1.9 17.9 8.8 359 8 358 165 4.1 0 4.3 4 05/21/2006 00:10:00 14 1.5 18.3 9.9 11.5 2.3 16.8 6.8 13.5 1.5 17.2 9.1 356 9 7 165 4.1 0 4.3 4 05/21/2006 00:20:00 14.5 1.7 20.2 10.7 11.6 2.5 18.3 6.1 14.2 1.8 19.9 9.1 356 8 359 165 4.1 0 4.3 4 05/21/2006 00:30:00 13.5 1.9 18.3 7.6 11.6 2 16.8 6.5 13 2.2 18.7 7.2 352 9 11 165 4.1 0 4.3 3.5 05/21/2006 00:40:00 14.1 1.7 18.3 9.9 12.5 2.5 17.6 6.1 13.4 1.6 17.9 9.5 355 9 355 165 4.1 0 4.3 4 05/21/2006 00:50:00 13.8 1.5 18.7 10.3 12 2.3 17.6 7.2 13.1 1.7 17.9 9.1 353 8 0 165 4.1 0 4.3 4 05/21/2006 01:00:00 13.2 1.9 16.8 8.4 12 2.4 17.6 6.5 12.5 2.1 17.2 6.8 351 9 344 165 4.1 0 4.3 4 05/21/2006 01:10:00 15.3 1.7 20.2 10.3 12.4 2.5 18.7 7.6 15 1.8 18.7 9.9 356 7 358 165 4.1 0 4.3 4 05/21/2006 01:20:00 14.2 1.6 19.5 9.5 12.1 2 17.6 7.6 13.9 1.6 18.7 9.5 354 7 357 165 4.1 0 4.3 3.8 05/21/2006 01:30:00 14.1 1.4 17.9 10.3 11.2 2.1 17.2 7.2 13.9 1.6 17.6 9.1 358 8 359 165 4.1 0 4.3 3.8 05/21/2006 01:40:00 14.9 1.7 19.9 9.9 11.7 2.4 17.9 7.2 14.3 1.8 18.7 10.7 357 7 360 165 4.1 0 4.3 3.8 05/21/2006 01:50:00 13.7 1.7 19.1 9.9 11.7 2.1 18.3 7.2 13.1 1.7 19.1 9.5 355 8 354 165 4.1 0 4.3 3.8 05/21/2006 02:00:00 13.2 1.9 19.9 9.1 11.1 2.3 17.2 7.2 12.6 2.2 19.1 7.6 355 9 8 165 4.1 0 4.5 4 05/21/2006 02:10:00 13.1 1.9 17.9 8 11.5 2.5 18.3 6.5 12.4 1.8 16.4 7.2 355 10 346 165 4.2 0 4.5 4 05/21/2006 02:20:00 13.2 2.3 18.3 6.8 10.2 1.6 14.9 5.7 12.4 2.6 18.3 6.5 357 9 2 165 4.3 0 4.5 3.8 05/21/2006 02:30:00 13.5 1.7 17.9 7.6 10.4 1.7 15.6 5.3 13.1 1.8 18.3 6.8 0 8 16 165 4.4 0 4.5 4.3 05/21/2006 02:40:00 11.4 1.7 16.1 6.8 9.9 1.8 14.1 5.3 10.9 1.8 17.2 6.5 353 9 351 165 4.5 0 4.8 4.5 05/21/2006 02:50:00 8.3 1.5 12.6 4.9 7.5 1.4 12.2 3.8 7.8 1.6 12.6 4.2 351 14 5 165 4.4 0 4.5 4 05/21/2006 03:00:00 8.7 1.3 12.2 5.7 7.5 1.4 11.5 4.2 8.7 1.6 12.2 5.3 354 13 354 165 4.4 0 4.8 4.3 05/21/2006 03:10:00 9.4 2.3 14.5 5.3 8.7 2.1 14.5 3.8 9.2 2.4 15.6 4.6 348 11 1 165 4.6 0 4.8 4.5 05/21/2006 03:20:00 9.9 1.2 13.3 6.8 8.7 1.7 12.6 4.6 10.1 1.4 14.1 7.2 353 13 2 165 4.7 0 4.8 4.5 05/21/2006 03:30:00 9.2 1.9 14.5 4.6 8.3 2.1 14.9 3.8 9.3 1.8 14.5 5.7 348 14 348 165 4.8 0 5 4.5 05/21/2006 03:40:00 9.9 1.7 14.5 5.3 9.2 2 14.5 4.9 9.8 1.8 14.9 4.6 341 16 345 165 4.8 0 5 4.8 05/21/2006 03:50:00 10.9 2.2 18.7 4.9 10.8 2.3 18.3 4.6 10.4 2.1 19.1 4.9 327 16 334 165 4.9 0 5.2 4.8 05/21/2006 04:00:00 10.5 1.6 14.5 7.2 10.3 1.7 14.9 5.7 9.8 1.5 14.5 6.8 328 17 344 165 5 0 5.2 4.8 05/21/2006 04:10:00 11.3 2.9 19.1 5.7 11.1 3.1 18.3 4.6 10.6 2.8 17.9 4.6 330 15 319 165 5 0 5.2 4.8 05/21/2006 04:20:00 10.9 2.4 17.2 5.7 10.9 2.3 16.8 5.3 10.4 2.2 15.3 4.6 331 12 339 165 5.1 0 5.2 4.8 05/21/2006 04:30:00 11 1.7 16.8 6.5 10.5 2 16.8 6.1 10.7 1.9 16.1 6.1 339 14 338 165 5.1 0 5.2 5 05/21/2006 04:40:00 11.6 2.4 17.6 6.5 11.3 2.7 17.6 4.9 11 2.2 17.6 6.1 336 14 314 165 5.1 0.1 5.2 5 05/21/2006 04:50:00 10.9 2.2 16.4 6.5 10.4 2.5 17.2 6.1 10.4 2.2 16.8 6.5 345 16 346 165 5.1 0 5.5 5 05/21/2006 05:00:00 10.6 2 15.6 6.1 9.9 2.2 14.9 4.9 10.2 2.1 15.3 5.3 344 15 3 165 5.2 0 5.5 4.5 05/21/2006 05:10:00 9.3 1.5 13.3 6.1 8.9 1.5 12.6 5.3 9.2 1.5 13.3 5.7 341 12 316 165 5.2 0 5.5 5 05/21/2006 05:20:00 9 1.2 13 5.7 8.3 1.4 12.2 4.2 8.9 1.2 11.8 5.7 350 13 352 165 5.2 0.1 5.5 4.5 05/21/2006 05:30:00 9.5 2 16.1 5.7 9.3 2.1 16.1 3.8 9.1 1.8 15.6 5.7 337 15 325 165 5.4 0 5.7 5 05/21/2006 05:40:00 10.3 2.5 22.1 6.1 10.2 2.5 21.8 5.3 9.9 2.3 18.3 5.7 328 12 312 165 5.5 0 5.7 5 05/21/2006 05:50:00 11.5 2.5 19.1 5.7 10.8 2.9 18.7 4.9 11.4 2.5 18.3 6.8 342 15 338 165 5.6 0 5.7 5 05/21/2006 06:00:00 10.1 1.2 16.1 6.8 10.1 1.2 15.3 6.5 9.8 1.2 13.3 6.8 335 9 326 165 5.5 0 5.7 5 05/21/2006 06:10:00 8.8 1.3 12.2 4.6 8.4 1.3 12.2 4.6 8.6 1.3 11.5 3.4 341 15 350 165 5.6 0.1 5.7 5 05/21/2006 06:20:00 9.9 1.4 13.7 6.1 9.7 1.5 13.7 4.9 9.8 1.4 14.1 6.1 343 9 344 165 5.6 0.2 5.7 5 05/21/2006 06:30:00 9.2 1.3 12.6 6.1 9 1.3 12.6 6.1 8.9 1.4 13.3 6.1 334 13 336 165 5.7 0.2 6 5.2 05/21/2006 06:40:00 9.2 1.5 13 4.9 9 1.6 13 4.9 8.6 1.6 13 5.3 329 17 297 165 5.8 0.1 6 5.5 05/21/2006 06:50:00 8.8 1.5 13.7 5.7 8.6 1.7 14.1 5.3 8.6 1.6 13.7 5.3 335 14 322 165 5.9 0.1 6 5.5 05/21/2006 07:00:00 9.3 1.3 13.3 6.5 9.2 1.5 13.7 6.1 9.1 1.5 13.7 6.1 331 13 349 165 5.9 0 6 5.5 05/21/2006 07:10:00 8.9 1.5 13.3 5.3 8.6 1.5 12.6 4.9 8.4 1.7 13.3 4.6 334 15 358 165 5.9 0 6.2 5.5 05/21/2006 07:20:00 9.7 1.6 14.1 6.5 9.1 1.7 14.5 4.6 9.5 1.7 13.3 6.1 337 15 344 165 6.1 0.1 6.2 5.7 05/21/2006 07:30:00 10.3 1.8 16.1 6.1 10.3 1.8 15.6 6.1 10 2.2 16.1 5.3 330 12 338 165 6.2 0.1 6.5 5.7 05/21/2006 07:40:00 10.7 2.1 17.2 6.5 10.5 2.3 17.2 6.5 10.6 2.3 17.2 6.1 338 11 339 165 6.4 0 6.5 6.2 05/21/2006 07:50:00 11.5 2 15.6 6.8 11.3 2 15.6 6.5 11.3 2.2 16.4 6.5 339 10 327 165 6.4 0 6.7 5.7 05/21/2006 08:00:00 11.6 1.9 16.4 6.8 11.5 1.9 15.6 6.5 11.5 2 15.6 7.2 337 10 340 165 6.4 0.1 6.7 5.7 05/21/2006 08:10:00 10 1.5 14.9 6.5 9.9 1.5 15.3 6.1 9.7 1.5 14.1 5.7 337 10 347 165 6.4 0.1 6.7 5.7 05/21/2006 08:20:00 8.3 0.9 10.7 6.1 8.2 0.9 10.7 4.9 7.8 1.1 11.5 5.3 325 12 312 165 6.3 0.1 6.5 5.7 05/21/2006 08:30:00 8 1.2 11.5 4.6 7.9 1.2 10.7 4.6 7.8 1.2 10.3 4.2 330 15 349 165 6.3 0.2 6.7 5.7 05/21/2006 08:40:00 9 1.7 14.5 4.2 9 1.7 14.5 4.6 8.2 1.7 13.7 4.2 316 14 313 165 6.4 0.1 6.7 6 05/21/2006 08:50:00 8.8 1.5 13.7 5.3 8.7 1.5 13.7 4.6 8.4 1.3 12.2 4.9 331 13 292 165 6.2 0.2 6.7 5.7 05/21/2006 09:00:00 9.8 1.7 14.9 5.7 9.4 1.8 15.3 5.3 9.1 1.8 16.1 5.3 331 18 339 165 6.2 0.2 6.7 5.7 05/21/2006 09:10:00 10 1.2 13.3 7.2 10 1.2 14.1 7.2 9.6 1.3 13.3 6.1 329 15 344 165 6.3 0.1 6.7 6 05/21/2006 09:20:00 9 1.1 13.7 6.8 8.9 1.2 14.1 6.1 8.4 1.3 14.1 5.3 320 16 343 165 6.4 0.1 6.7 6 05/21/2006 09:30:00 8.1 1.2 11.1 5.3 8.1 1.1 11.1 4.9 7.5 1.1 10.3 4.6 316 11 318 165 6.4 0.1 6.7 6 05/21/2006 09:40:00 8.2 1.2 11.5 4.9 8.1 1.2 11.5 4.6 7.5 1.1 10.7 3.8 315 11 318 165 6.4 0.1 6.7 6 05/21/2006 09:50:00 7.9 0.8 9.9 5.3 7.9 0.8 9.9 5.3 7 1 9.5 3.4 312 10 326 165 6.6 0.2 7 6.2 05/21/2006 10:00:00 8.8 1 11.8 5.3 8.8 1 11.8 5.3 7.5 1.2 10.7 4.2 308 9 301 165 6.7 0 7 6.2 05/21/2006 10:10:00 10 1 12.6 6.5 10 1 12.2 6.8 8.1 1.1 10.7 4.9 305 7 300 165 6.9 0.1 7.3 6.7 05/21/2006 10:20:00 11 1.5 14.9 6.8 11 1.5 14.5 6.5 9 1.4 14.1 5.7 307 7 315 165 7.1 0 7.3 7 05/21/2006 10:30:00 10.4 1.5 14.5 6.8 10.4 1.4 14.5 6.8 8.9 1.4 13.7 6.1 308 8 297 165 7.4 0.1 7.8 7 05/21/2006 10:40:00 10.5 1.3 13.7 6.8 10.5 1.3 14.1 7.2 9 1.2 12.2 5.3 307 9 292 165 7.6 0 8 7.3 05/21/2006 10:50:00 10.2 1.4 14.1 6.5 10.2 1.4 13.7 6.1 8.7 1.4 13.7 5.3 307 9 293 165 8 0.2 8.3 7.3 05/21/2006 11:00:00 9.2 1.1 13 6.1 9.2 1.1 12.2 6.1 8.2 1.1 11.1 5.7 311 11 300 165 8.5 0.1 8.8 7.8 05/21/2006 11:10:00 8.7 1.2 12.6 5.3 8.6 1.2 12.2 5.7 7.8 1.3 12.6 4.6 314 12 319 165 8.5 0.2 9 8 05/21/2006 11:20:00 8.1 1.1 10.7 4.9 8.1 1.2 11.1 4.9 7.2 1 9.9 4.6 317 15 298 165 8.7 0.2 9.3 8.5 05/21/2006 11:30:00 7.5 1.4 9.9 3 7.5 1.3 10.3 3 7 1.3 9.9 3.4 318 15 330 165 9.6 0.1 9.8 9.3 05/21/2006 11:40:00 7.4 1.5 11.1 3.8 7.4 1.5 11.1 3.4 6.4 1.2 9.9 3.4 313 17 290 165 10 0.1 10.6 9.6 05/21/2006 11:50:00 8.5 1.3 14.1 4.9 8.5 1.3 14.1 5.3 7.2 1.3 12.2 4.2 305 10 285 165 8.9 0.3 9.6 8.5 05/21/2006 12:00:00 9.6 1 12.2 7.2 9.6 1 12.2 7.2 7.9 1.2 11.1 5.3 304 8 308 165 8.9 0.2 9.3 8.5 05/21/2006 12:10:00 9.2 1.2 13 6.1 9.2 1.2 13 6.5 8 1.5 11.5 4.2 309 10 293 165 9.4 0.2 9.8 9 05/21/2006 12:20:00 9.4 1.3 13 6.1 9.5 1.3 13.3 5.7 7.9 1.2 11.5 5.3 303 10 290 165 9.2 0.2 9.6 8.8 05/21/2006 12:30:00 10 1.1 13.7 6.8 10 1.1 13.3 6.8 8.2 1.2 11.1 5.3 305 7 303 165 9.2 0.2 9.6 8.8 05/21/2006 12:40:00 10.8 1.3 14.1 6.5 10.8 1.3 14.1 7.2 8.5 1.3 13 5.3 304 7 301 165 8.9 0.2 9.3 8.5 05/21/2006 12:50:00 11.5 1.3 16.4 8.8 11.5 1.2 16.4 8.8 9.9 1.6 14.9 6.5 310 9 312 165 8.7 0 9 8.5 05/21/2006 13:00:00 11.7 1.3 15.3 8 11.7 1.4 15.3 8 9.6 1.5 14.5 5.7 307 8 309 165 9.1 0.1 9.6 8.8 05/21/2006 13:10:00 11.8 1.3 15.6 7.6 11.8 1.2 15.6 8.4 9.8 1.3 15.6 7.2 308 7 328 165 9.4 0.3 9.8 9 05/21/2006 13:20:00 11.7 1.7 16.8 8.4 11.8 1.6 16.4 8 9.6 1.9 17.6 5.3 305 8 308 165 9.7 0.1 10.3 9.6 05/21/2006 13:30:00 12.7 1.5 16.8 8.8 12.7 1.5 17.2 8.8 10.5 1.8 16.4 7.2 309 11 307 165 9.5 0.1 9.8 9 05/21/2006 13:40:00 12 1.5 15.6 8 12 1.5 15.6 8.4 9.7 1.3 13 5.7 306 7 307 165 9.9 0.2 10.3 9.3 05/21/2006 13:50:00 12.2 1.5 16.4 8.4 12.2 1.5 16.4 8.4 10.2 1.5 14.9 7.2 308 7 305 165 9.9 0.2 10.3 9.6 05/21/2006 14:00:00 11.6 1.6 16.1 6.8 11.6 1.5 15.3 6.8 9.8 1.5 14.9 4.9 307 8 302 165 9.8 0.2 10.3 9.3 05/21/2006 14:10:00 12.4 1.3 16.1 9.5 12.4 1.3 16.1 9.5 10.4 1.3 14.1 6.5 308 6 308 165 9.8 0.1 10.1 9.6 05/21/2006 14:20:00 12.4 1.2 16.1 8.8 12.4 1.2 16.1 9.1 10.1 1.2 14.1 7.2 307 6 305 165 10 0.2 10.6 9.6 05/21/2006 14:30:00 12.2 1.3 16.4 8.4 12.1 1.3 16.4 8.4 10.2 1.6 15.6 6.8 309 8 307 165 9.8 0.1 10.1 9.6 05/21/2006 14:40:00 12.1 1.1 16.4 9.1 12 1.1 16.4 9.1 10.5 1.3 13.3 7.2 311 9 303 165 9.6 0 9.8 9.3 05/21/2006 14:50:00 12.3 1.3 15.6 8.8 12.2 1.2 15.6 9.1 10.7 1.5 14.9 7.2 310 6 308 165 9.8 0.2 10.3 9.6 05/21/2006 15:00:00 12.7 1.3 16.4 9.1 12.6 1.3 16.8 9.5 11 1.5 15.6 7.2 311 6 310 165 9.8 0.1 10.1 9.6 05/21/2006 15:10:00 13.7 1.2 16.8 10.7 13.6 1.2 16.8 10.7 11.6 1.4 15.6 8.8 310 7 303 165 9.6 0.1 10.3 9.6 05/21/2006 15:20:00 13.2 1.1 16.4 9.9 13.2 1.1 16.1 9.5 11.3 1.5 14.5 8 310 6 307 165 9.7 0.1 9.8 9.3 05/21/2006 15:30:00 13.1 1.2 16.8 9.9 13 1.3 16.4 9.9 11.3 1.3 14.9 8.4 309 6 305 165 9.4 0 9.6 9 05/21/2006 15:40:00 13.2 1.3 16.8 9.9 13.2 1.3 17.2 9.9 11.4 1.4 15.3 7.6 310 6 305 165 9.5 0.1 9.6 9 05/21/2006 15:50:00 13.4 1.1 15.6 9.9 13.2 1.1 15.6 9.9 12.5 1.1 16.8 9.1 314 5 310 165 9.7 0.2 10.3 9.6 05/21/2006 16:00:00 12.7 1 15.6 9.5 12.6 1 15.6 9.9 11.4 1.3 14.5 7.6 312 7 307 165 10 0.1 10.6 9.6 05/21/2006 16:10:00 12.7 1.3 17.2 9.1 12.6 1.3 16.4 9.5 11.2 1.4 14.5 7.2 311 7 295 165 9.8 0 10.1 9.6 05/21/2006 16:20:00 12.6 1 15.6 8.4 12.5 1.1 16.1 8.8 10.8 1.2 13.7 7.6 309 6 307 165 10 0 10.3 9.8 05/21/2006 16:30:00 12.4 1.2 16.1 8.4 12.3 1.2 15.3 8.4 10.8 1.7 15.6 6.5 310 7 321 165 10.1 0 10.3 9.8 05/21/2006 16:40:00 12.7 1.3 15.6 8.8 12.7 1.2 15.6 8.8 10.5 1.5 14.9 7.2 308 7 301 165 10 0 10.3 9.8 05/21/2006 16:50:00 12.8 1.3 16.8 8.8 12.8 1.3 17.2 9.1 10.9 1.5 16.1 6.8 309 7 310 165 10 0 10.3 9.8 05/21/2006 17:00:00 13.1 1.2 16.4 10.3 13 1.2 16.4 10.3 11.3 1.4 15.6 8 310 7 304 165 10 0.1 10.3 9.6 05/21/2006 17:10:00 13.4 1.3 19.1 10.3 13.3 1.4 18.7 9.9 11.5 1.3 17.6 8 309 7 321 165 9.9 0.2 10.6 9.3 05/21/2006 17:20:00 13.7 1.3 17.2 10.7 13.6 1.3 16.8 10.3 12 1.6 15.6 8.8 310 6 319 165 9.6 0 9.6 9.3 05/21/2006 17:30:00 14.5 1.2 18.3 10.7 14.4 1.2 17.9 10.7 12.1 1.4 16.8 8.8 308 7 309 165 9.6 0 9.8 9.3 05/21/2006 17:40:00 13.2 1.6 17.6 8 13.2 1.5 17.6 8.4 11.3 1.7 16.1 7.2 309 8 310 165 9.8 0 10.1 9.3 05/21/2006 17:50:00 12.8 1.3 17.2 8.8 12.8 1.3 17.6 8.8 11.3 1.3 15.3 8 311 9 305 165 10.1 0 10.3 9.6 05/21/2006 18:00:00 11.7 1.6 15.3 7.2 11.7 1.6 15.3 6.8 10.4 1.7 14.5 5.3 312 11 306 165 10.8 0.4 11.7 10.1 05/21/2006 18:10:00 10.2 1.7 14.9 4.6 10.3 1.6 14.5 5.3 8.9 1.5 13 3.8 308 15 297 165 11.3 0.2 11.7 10.9 05/21/2006 18:20:00 10.8 1.5 14.9 6.8 10.7 1.5 14.9 7.2 9.9 1.5 13.7 6.5 315 11 303 165 10.1 0.1 10.9 9.6 05/21/2006 18:30:00 11.7 1.4 15.3 8 11.6 1.4 15.3 8 10.5 1.5 14.5 7.2 310 8 304 165 9.9 0.2 10.3 9.6 05/21/2006 18:40:00 13.3 1.3 17.6 9.9 13.2 1.3 17.2 9.9 11.3 1.4 15.3 8 308 7 312 165 9.2 0.1 9.6 8.5 05/21/2006 18:50:00 13.7 1.2 17.6 9.5 13.6 1.3 17.2 9.1 11.7 1.6 17.2 7.6 310 6 301 165 9 0.2 9.3 8.5 05/21/2006 19:00:00 13.4 1.4 16.8 10.3 13.4 1.3 16.4 9.9 11 1.3 14.5 7.6 308 7 297 165 9 0 9 8.8 05/21/2006 19:10:00 13.3 1.1 17.6 11.1 13.3 1.1 17.6 10.7 11.4 1.5 16.8 7.6 310 6 318 165 9 0 9.3 8.5 05/21/2006 19:20:00 12.9 1.2 16.1 9.5 12.8 1.2 15.6 9.5 11 1.5 15.6 6.5 309 8 319 165 9 0 9.3 8.8 05/21/2006 19:30:00 13.5 1.3 19.1 9.9 13.4 1.3 18.7 10.3 11.6 1.5 17.6 7.6 310 7 314 165 9.3 0.2 9.6 8.5 05/21/2006 19:40:00 14.3 1.2 18.3 11.5 14.2 1.2 18.3 11.1 12.1 1.5 17.6 8.8 310 7 301 165 9.3 0.1 9.6 8.8 05/21/2006 19:50:00 14.9 1.5 18.7 9.9 14.9 1.5 18.7 9.9 12.7 1.3 16.1 9.1 309 5 303 165 9.1 0.1 9.3 8.5 05/21/2006 20:00:00 14.8 1.2 17.6 11.5 14.7 1.2 17.6 11.1 13 1.2 17.2 8.8 310 6 307 165 9 0 9 8.5 05/21/2006 20:10:00 14.2 1.3 17.6 11.1 14.1 1.3 17.6 11.1 12.2 1.6 16.1 7.6 309 7 316 165 8.9 0 9 8.8 05/21/2006 20:20:00 15.4 1.3 18.7 12.2 15.3 1.3 18.7 12.2 13.4 1.4 16.8 9.1 311 6 296 165 8.5 0.1 8.8 8.3 05/21/2006 20:30:00 15.1 1.3 19.1 11.5 15 1.3 18.7 11.5 13.2 1.5 16.4 9.5 310 6 290 165 8.2 0.1 8.5 8 05/21/2006 20:40:00 14.2 1.2 18.7 10.3 14.1 1.2 18.3 10.7 11.8 1.6 18.3 8 310 6 323 165 8 0 8.5 7.5 05/21/2006 20:50:00 14.6 1.3 17.2 10.7 14.5 1.3 17.2 11.1 12.7 1.4 15.3 9.1 311 6 317 165 7.8 0.1 8 7.5 05/21/2006 21:00:00 15.4 1.4 19.1 10.7 15.3 1.5 18.7 9.9 13 1.5 16.8 9.1 309 5 311 165 7.6 0 8 7.5 05/21/2006 21:10:00 16.2 1.2 19.1 12.2 16.1 1.2 19.5 12.6 14 1.3 17.9 11.1 310 4 304 165 7.6 0 7.8 7.3 05/21/2006 21:20:00 16.7 1.3 19.9 13.7 16.6 1.3 19.9 14.1 14.6 1.7 17.9 9.5 310 5 303 165 7.5 0 7.8 7.3 05/21/2006 21:30:00 16.6 1.3 19.1 13.3 16.5 1.3 19.1 13.3 14.5 1.5 18.3 10.7 310 4 310 165 7.6 0 7.8 7.3 05/21/2006 21:40:00 17 1.2 19.5 13.3 17 1.2 19.9 13 14.2 1.3 17.2 9.9 308 5 302 165 7.6 0 8 7.3 05/21/2006 21:50:00 16.3 1.1 18.7 11.5 16.2 1.1 18.3 11.1 13.4 1.3 16.8 9.9 309 4 313 165 7.9 0.1 8.3 7.5 05/21/2006 22:00:00 17.2 1.2 19.5 14.1 17.1 1.1 19.5 13.7 14.6 1.4 17.6 10.7 309 3 309 165 7.9 0 8.3 7.8 05/21/2006 22:10:00 16.8 1.1 19.9 13.3 16.7 1.1 19.5 13 14.6 1.2 17.9 11.5 311 4 308 165 7.7 0 8 7.5 05/21/2006 22:20:00 16.7 1.1 18.7 13 16.5 1.1 18.7 13 14.8 1.5 17.9 10.3 311 4 310 165 7.6 0 7.8 7.5 05/21/2006 22:30:00 17.2 1.1 19.9 13.7 17.1 1.1 19.9 13.3 15.1 1.2 18.3 11.8 310 4 305 165 7.6 0 8 7.3 05/21/2006 22:40:00 16.7 1.1 19.1 12.6 16.7 1.1 19.1 12.6 13.6 1.3 17.2 9.9 307 4 307 165 7.7 0 8 7.5 05/21/2006 22:50:00 16.2 1.5 20.6 11.5 16.1 1.5 20.2 11.5 14.4 1.4 17.9 11.1 311 5 307 165 7.6 0 7.8 7.3 05/21/2006 23:00:00 15.6 1.2 18.3 12.6 15.4 1.3 18.3 12.2 14.2 1.3 17.9 10.3 313 4 310 165 7.6 0 7.8 7.3 05/21/2006 23:10:00 15.4 1.2 17.9 12.6 15.3 1.3 17.9 11.8 12.7 1.1 15.6 8.8 308 5 303 165 7.6 0 7.8 7.3 05/21/2006 23:20:00 16 1.1 18.3 13 16 1.2 17.9 12.6 12.4 1.3 16.1 8.8 305 4 310 165 7.4 0.1 7.8 7.3 05/21/2006 23:30:00 15.8 1.1 18.7 11.8 15.7 1.1 18.3 11.8 12.2 1.3 16.4 9.1 306 5 302 165 7.6 0 8 7.3 05/21/2006 23:40:00 16.5 1.1 19.1 13.3 16.5 1.1 18.7 13 13.3 1.3 16.4 9.5 307 4 310 165 7.4 0.1 7.8 7.3 05/21/2006 23:50:00 16.2 1 18.3 12.6 16.2 1.1 18.7 12.2 12.4 1.3 16.4 9.1 306 4 300 165 7.3 0.1 7.8 7 05/22/2006 00:00:00 14.8 1.2 17.6 11.5 14.8 1.2 17.6 11.1 11.5 1.5 15.3 8.4 305 5 313 165 7.4 0.1 7.8 7 05/22/2006 00:10:00 13.4 1.7 17.2 9.5 13.4 1.7 16.8 9.9 10.1 1.3 13.7 6.8 302 6 299 165 7.4 0.1 7.8 7 05/22/2006 00:20:00 14.7 1.7 17.9 9.5 14.7 1.7 17.9 9.9 11.2 1.3 15.3 7.2 303 6 298 165 7.3 0.1 7.8 7 05/22/2006 00:30:00 14.1 1.3 17.6 11.1 14 1.3 17.6 10.7 10.8 1.3 15.6 7.6 303 6 314 165 7.4 0.1 8 7 05/22/2006 00:40:00 13.6 1.5 16.8 9.5 13.5 1.4 16.8 9.1 11 1.6 15.3 7.6 305 9 303 165 7.6 0.1 8 7 05/22/2006 00:50:00 14.7 1.3 18.7 11.1 14.7 1.3 18.3 11.5 11.6 1.5 17.6 8.8 305 6 311 165 7.6 0.1 7.8 7.3 05/22/2006 01:00:00 15.3 1.7 21 9.9 15.2 1.7 20.2 10.3 12.3 2.2 19.9 8 307 8 304 165 7.7 0.2 8.3 7.3 05/22/2006 01:10:00 15 1.5 18.3 10.3 14.9 1.5 18.3 10.3 12.4 1.7 17.2 8.8 307 7 297 165 7.7 0.1 8.3 7.3 05/22/2006 01:20:00 14.6 1.5 18.7 10.3 14.6 1.5 18.7 9.9 11.7 1.5 17.6 8.8 305 7 301 165 7.8 0.2 8.3 7.3 05/22/2006 01:30:00 14.5 1.4 18.3 11.5 14.4 1.4 18.3 11.5 11.7 1.7 16.4 8 306 7 304 165 7.7 0.2 8 7.3 05/22/2006 01:40:00 14.8 1.3 18.3 9.9 14.7 1.3 17.9 10.3 12.1 1.5 17.6 8 306 7 315 165 7.8 0.2 8.3 7.3 05/22/2006 01:50:00 14.5 1.3 18.7 11.1 14.4 1.3 18.7 10.7 11.4 1.7 17.6 7.2 304 8 310 165 7.8 0.2 8.3 7.3 05/22/2006 02:00:00 14.2 1.5 18.3 10.3 14.1 1.5 17.9 10.3 11.3 1.6 17.2 8 306 8 306 165 7.9 0.2 8.5 7.5 05/22/2006 02:10:00 13.7 1.5 17.2 8.4 13.6 1.5 17.2 8.4 11.6 1.5 16.4 7.6 310 9 296 165 7.8 0.2 8.3 7.5 05/22/2006 02:20:00 12.9 1.4 16.1 9.1 12.7 1.4 16.1 9.1 11.5 1.7 14.9 7.6 312 7 305 165 7.8 0.2 8 7.3 05/22/2006 02:30:00 13.8 1.3 17.6 9.9 13.6 1.2 17.2 9.9 12 1.7 16.1 6.8 311 8 293 165 8.3 0.2 8.8 7.8 05/22/2006 02:40:00 14.1 1.5 19.9 9.5 14 1.5 19.5 9.5 12.1 1.5 17.2 8.8 309 7 306 165 8 0.1 8.5 7.5 05/22/2006 02:50:00 14.6 1.3 19.1 11.1 14.5 1.4 19.5 10.7 11.6 1.4 16.1 8 306 7 308 165 7.8 0.2 8.5 7.3 05/22/2006 03:00:00 14 1.4 18.7 10.3 13.8 1.4 18.7 10.3 12.6 1.6 17.2 8.4 313 7 317 165 7.8 0.2 8.5 7.3 05/22/2006 03:10:00 13.1 1.5 17.6 9.5 13 1.4 17.6 9.5 12.2 1.6 17.2 7.6 318 8 325 165 8.5 0.3 9 8 05/22/2006 03:20:00 12.5 1.2 14.9 9.5 12.3 1.2 14.5 9.1 11.5 1.3 14.5 8.4 316 8 314 165 8.5 0.1 9 8 05/22/2006 03:30:00 13 1.1 15.3 9.1 12.9 1.1 15.3 9.5 11.7 1.3 14.9 8.4 314 8 313 165 8 0.1 8.5 7.5 05/22/2006 03:40:00 12.9 1.3 17.2 9.1 12.8 1.3 17.2 9.1 11.8 1.5 15.6 7.2 314 9 314 165 8.2 0.2 8.8 7.8 05/22/2006 03:50:00 12.9 1.5 16.4 8 12.7 1.5 16.1 7.6 12.4 1.6 16.8 8.4 318 7 325 165 8.4 0.2 9 8 05/22/2006 04:00:00 14.7 1.4 18.3 11.5 14.6 1.4 18.7 10.7 13.4 1.4 16.8 9.9 313 7 319 165 8 0.1 8.5 7.5 05/22/2006 04:10:00 15.3 1.2 18.7 12.2 15.2 1.2 18.7 11.5 13.5 1.5 16.8 9.1 311 8 300 165 8.1 0.2 8.5 7.5 05/22/2006 04:20:00 14.9 1.7 19.1 9.9 14.8 1.6 19.5 9.9 13.2 1.8 19.1 8.4 312 8 306 165 8.4 0.4 9 7.8 05/22/2006 04:30:00 13.9 1.7 18.7 8.4 13.8 1.7 18.3 9.1 12.8 1.5 17.6 9.1 316 10 306 165 8.3 0.2 8.8 7.8 05/22/2006 04:40:00 13.4 1.7 17.6 9.5 13.2 1.7 17.6 9.1 12.3 1.5 16.8 8.8 316 9 312 165 8.2 0.2 8.8 7.5 05/22/2006 04:50:00 13.6 1.2 16.8 9.5 13.4 1.2 16.4 9.5 13.2 1.2 16.1 8.8 323 8 329 165 8.5 0.1 9 8 05/22/2006 05:00:00 13.3 1.5 17.2 8.8 13.2 1.5 16.8 8.8 13.1 1.5 17.6 9.1 326 9 322 165 9.2 0.3 9.8 8.5 05/22/2006 05:10:00 12.8 1.4 16.8 9.9 12.7 1.4 16.8 9.5 12.5 1.4 17.2 8.8 322 7 319 165 9.2 0.1 9.6 8.5 05/22/2006 05:20:00 12.6 1.3 15.6 9.1 12.5 1.3 15.6 8.8 12.3 1.5 15.3 8.4 322 8 321 165 9.4 0.2 9.8 8.8 05/22/2006 05:30:00 13.3 1.3 16.1 9.9 13.1 1.2 16.1 10.3 13 1.3 16.8 9.5 325 8 325 165 9.6 0.1 10.1 9.3 05/22/2006 05:40:00 13.1 1.7 17.2 9.5 12.9 1.7 17.2 9.5 12.8 1.7 17.2 8.8 326 8 312 165 9.8 0.2 10.3 9.6 05/22/2006 05:50:00 12.5 1.5 16.8 8.4 12.3 1.6 17.6 8 12.3 1.5 16.8 9.1 334 9 351 165 10.6 0.1 10.9 10.1 05/22/2006 06:00:00 13 1.5 16.8 9.5 12.9 1.5 16.8 9.5 13.1 1.4 17.6 9.9 334 10 331 165 10.6 0.1 11.1 10.3 05/22/2006 06:10:00 12.2 1.4 16.8 8.8 12 1.5 17.2 8 11.8 1.6 16.4 8 328 11 340 165 10.6 0.1 11.1 10.1 05/22/2006 06:20:00 13.3 1.8 17.9 9.9 13.1 1.8 17.6 8.8 12.8 2 18.3 7.6 330 12 329 165 10.7 0.2 11.1 10.3 05/22/2006 06:30:00 13.1 1.6 17.6 9.1 13 1.5 17.2 9.1 12.7 1.5 17.6 7.2 327 8 330 165 10.7 0 10.9 10.6 05/22/2006 06:40:00 11.9 1.5 15.6 7.2 11.9 1.5 15.6 7.6 11.4 1.6 15.3 7.2 328 10 331 165 10.9 0 11.1 10.9 05/22/2006 06:50:00 13.2 1.8 18.7 9.1 13 1.9 18.3 8.8 12.9 1.8 18.3 9.1 332 10 328 165 11.1 0.2 11.4 10.9 05/22/2006 07:00:00 12.8 1.6 19.1 8.4 12.7 1.6 19.5 8.8 12.6 1.7 18.7 7.6 335 10 336 165 11.4 0.1 11.7 10.9 05/22/2006 07:10:00 12.5 1.7 18.7 8.8 12.4 1.7 18.3 8.8 12 1.7 17.2 8.4 332 9 338 165 11.6 0 11.9 11.4 05/22/2006 07:20:00 11.8 1.8 16.4 8.4 11.6 2 16.4 6.8 11.4 2 16.1 7.2 330 13 322 165 11.7 0 11.9 11.4 05/22/2006 07:30:00 12.2 1.7 17.2 7.6 11.8 1.7 16.8 7.6 11.9 1.9 17.2 6.5 334 12 330 165 11.9 0 12.2 11.4 05/22/2006 07:40:00 12.2 2.1 17.6 7.2 12.1 2.1 17.6 7.2 11.6 2.2 16.8 6.1 333 10 332 165 12 0 12.2 11.9 05/22/2006 07:50:00 12.3 1.4 16.4 8.8 12.2 1.4 16.1 8 11.7 1.5 15.3 8 332 11 325 165 12.3 0.1 12.5 11.9 05/22/2006 08:00:00 11.5 1.6 16.8 8 11.4 1.5 16.8 8 11.4 1.7 16.4 8 329 8 330 165 12.1 0 12.5 11.7 05/22/2006 08:10:00 11.8 1.4 15.3 7.6 11.6 1.6 15.6 6.8 11.6 1.5 16.1 6.8 332 12 333 165 12.4 0.1 12.7 11.9 05/22/2006 08:20:00 12.6 1.7 17.6 8 12.4 1.7 18.3 8.4 12.3 1.8 17.9 8 330 11 330 165 12.5 0 12.7 12.5 05/22/2006 08:30:00 13.1 1.5 17.2 9.5 13.1 1.4 17.2 9.9 13 1.5 16.4 9.1 331 9 323 165 12.5 0 12.7 12.5 05/22/2006 08:40:00 14.2 1.6 17.9 9.9 14.1 1.5 17.6 9.9 14.1 1.7 18.3 8.8 332 8 323 165 12.5 0 12.7 12.2 05/22/2006 08:50:00 13.4 1.5 17.9 9.5 13.3 1.5 17.9 9.1 13.3 1.5 17.2 7.6 333 8 339 165 12.7 0 13 12.5 05/22/2006 09:00:00 14 2 19.5 8.8 13.8 2.3 19.1 6.5 13.5 2 18.3 9.1 338 9 328 165 12.9 0 13.3 12.7 05/22/2006 09:10:00 11.9 1.4 15.6 8.8 11 2.2 16.1 5.3 11.3 1.6 15.6 7.2 345 11 334 165 13.3 0.1 13.5 13 05/22/2006 09:20:00 11.3 1.7 16.4 7.2 10.9 1.8 16.8 6.1 10.9 1.7 16.4 7.2 340 11 343 165 13.7 0 13.8 13.5 05/22/2006 09:30:00 11.6 1.5 15.3 7.6 11.3 1.9 15.3 5.7 11.3 1.5 15.3 7.6 338 13 346 165 13.8 0 14.4 13.5 05/22/2006 09:40:00 13.4 1.7 17.9 8.4 13.4 1.7 17.6 8.4 13.2 1.7 17.2 8 334 9 333 165 13.5 0 14.1 13.3 05/22/2006 09:50:00 13.8 1.6 17.6 10.3 13.7 1.7 18.3 9.9 13.4 1.9 18.3 8.4 337 9 329 165 13.4 0 14.1 13.3 05/22/2006 10:00:00 13.3 2 17.9 7.6 13.2 2.1 17.6 7.6 13 2.3 17.6 6.8 334 8 318 165 13.5 0.2 14.4 13.3 05/22/2006 10:10:00 12.2 1.9 18.3 7.2 12.1 2 17.6 6.5 11.9 2.2 18.3 6.1 336 9 353 165 13.8 0 14.1 13.5 05/22/2006 10:20:00 12.9 1.7 16.8 8 12.8 1.7 16.8 7.2 12.4 1.6 16.1 8 334 8 344 165 13.9 0 14.4 13.5 05/22/2006 10:30:00 12 1.8 16.4 6.8 12 2 17.2 7.6 11.7 2.1 16.8 6.5 337 9 337 165 14.2 0.1 14.6 13.8 05/22/2006 10:40:00 11.3 2 16.8 5.7 11.1 2.1 17.6 5.7 10.9 2.3 17.9 5.7 335 14 340 165 14 0.1 14.4 13.8 05/22/2006 10:50:00 10.5 2 15.3 6.1 10.1 2.1 14.9 5.3 10.2 2.2 14.9 5.7 337 14 328 165 14.6 0.2 15.5 14.1 05/22/2006 11:00:00 9.5 1.7 14.1 5.7 9.4 1.7 13.7 5.3 9.2 1.8 13.7 5.3 326 14 336 165 14.4 0.1 14.9 14.1 05/22/2006 11:10:00 9.2 1.5 13 5.3 9.1 1.4 13 4.9 8.6 1.4 12.6 4.9 320 12 307 165 14.6 0.1 14.9 14.4 05/22/2006 11:20:00 8.9 1.4 12.2 5.3 8.9 1.4 12.2 5.3 8.2 1.5 12.2 3.8 319 14 292 165 14.3 0 14.9 14.1 05/22/2006 11:30:00 8.4 1.2 12.2 4.9 8.4 1.2 12.6 5.3 7.5 1.1 10.7 3.8 317 15 300 165 14.8 0.2 15.2 14.6 05/22/2006 11:40:00 9.3 1.7 13 5.3 9.2 1.8 13.3 5.3 8.9 1.8 13 5.3 329 14 335 165 14.6 0 15.2 14.4 05/22/2006 11:50:00 8.2 1.7 12.2 3.8 8.2 1.7 12.6 4.2 7.5 1.7 11.8 3.8 316 16 332 165 14.7 0.2 15.2 14.6 05/22/2006 12:00:00 7.6 1.2 11.1 4.2 7.6 1.2 11.1 4.2 7.4 1.3 11.1 3.8 318 16 323 165 14.8 0 15.2 14.6 05/22/2006 12:10:00 7.1 1.5 10.3 2.6 7.3 1.4 10.3 3 6.5 1.3 10.3 2.6 299 22 334 165 15 0.3 16 14.6 05/22/2006 12:20:00 7.2 1.3 9.9 3.8 7.2 1.3 9.9 4.2 6.5 1.2 9.9 3 307 15 304 165 15.2 0.2 15.7 14.6 05/22/2006 12:30:00 7 1.3 10.3 2.6 7.2 1.2 10.3 4.2 6.4 1.4 10.7 2.6 302 14 294 165 15.2 0.1 15.7 14.9 05/22/2006 12:40:00 7.3 1.3 10.3 4.2 7.3 1.3 10.3 3.8 6.6 1.5 10.3 3.4 311 18 322 165 15.2 0.1 15.7 14.9 05/22/2006 12:50:00 6.5 1.7 10.7 2.6 6.5 1.7 10.7 3 6.2 2 11.8 2.3 325 22 330 165 15.5 0.3 16.3 14.9 05/22/2006 13:00:00 7.3 1.4 11.5 4.2 7.2 1.7 11.5 3 7 1.5 10.7 4.2 330 17 343 165 16 0.1 16.6 15.7 05/22/2006 13:10:00 6.7 1.2 9.5 3.4 6.7 1.2 9.1 3.4 6.5 1.3 9.1 3.4 324 17 353 165 16.1 0.1 16.6 16 05/22/2006 13:20:00 7.5 1.4 11.1 4.2 7.6 1.3 11.1 4.2 6.5 1.3 10.3 3.8 300 12 312 165 15.8 0.2 16.3 15.5 05/22/2006 13:30:00 7.5 1.2 10.3 4.9 7.6 1.1 10.3 4.9 6.8 1.2 9.9 4.2 312 12 333 165 16.1 0.6 17.1 15.5 05/22/2006 13:40:00 7.9 1.5 11.8 3.4 8 1.4 12.6 4.2 6.7 1.3 11.1 3.8 302 12 314 165 16.6 0.4 17.4 16 05/22/2006 13:50:00 8.8 0.9 11.5 5.7 8.9 0.9 11.5 6.1 7.4 1.2 10.7 4.9 297 9 313 165 15.5 0.1 16 15.2 05/22/2006 14:00:00 9.1 1.2 13 5.7 9.2 1.2 12.6 6.1 7.8 1.3 11.5 4.9 300 12 302 165 15.3 0 16 15.2 05/22/2006 14:10:00 8.2 0.9 11.1 6.1 8.3 0.9 11.5 6.1 7.3 1.2 11.1 4.6 306 11 309 165 16 0.4 16.8 15.2 05/22/2006 14:20:00 8.5 1.1 13 5.3 8.6 1 13 6.1 7.4 1.3 10.3 4.2 299 12 291 165 15.9 0.2 16.8 15.5 05/22/2006 14:30:00 8 1.2 11.5 5.7 8.2 1.1 11.5 5.7 6.8 1.2 11.1 4.2 299 8 290 165 15.7 0.3 16.8 15.2 05/22/2006 14:40:00 7.2 1.3 11.1 2.6 7.4 1.3 11.1 2.6 6.8 1.2 10.7 3.8 309 14 314 165 15.8 0.2 16.6 15.5 05/22/2006 14:50:00 7.5 1.2 10.7 3.8 7.6 1.1 11.1 4.2 6.5 1.2 9.5 3 305 11 290 165 15.9 0.1 16.6 15.5 05/22/2006 15:00:00 7.2 1.1 9.5 4.2 7.3 1.1 9.5 4.2 6.7 1.2 9.1 3.4 311 17 288 165 16.1 0.2 16.8 15.7 05/22/2006 15:10:00 6.5 1.3 9.9 2.3 6.7 1.3 9.5 2.6 6 1.3 9.9 3 301 20 301 165 16 0.3 16.8 15.7 05/22/2006 15:20:00 8.4 1.3 12.2 4.9 8.5 1.3 11.8 4.9 7.2 1.1 10.3 4.6 306 9 310 165 15.8 0.2 16.6 15.2 05/22/2006 15:30:00 7.4 1.1 11.5 4.9 7.5 1 11.1 4.9 6.8 1.3 12.2 3.8 298 11 294 165 15.7 0.1 16.3 15.5 05/22/2006 15:40:00 7.2 1.4 11.5 3.4 7.3 1.3 11.8 3.8 6.2 1.3 9.5 3.8 298 11 285 165 15.7 0.2 16.3 15.2 05/22/2006 15:50:00 7.8 1.4 12.6 4.9 7.9 1.3 12.6 4.9 6.7 1.3 12.2 3.8 303 9 287 165 15 0.2 15.7 14.6 05/22/2006 16:00:00 7.9 1.2 13.3 5.3 8.1 1.3 13.7 4.6 6.7 1.2 11.8 3.8 302 10 297 165 15.4 0.3 16 14.9 05/22/2006 16:10:00 8.5 1.2 12.2 5.7 8.6 1.2 12.2 5.7 7.1 1.2 11.1 3.8 300 8 305 165 15.2 0 15.5 14.9 05/22/2006 16:20:00 8.6 1 12.6 4.9 8.7 1 11.8 5.3 7.1 1 11.1 4.6 303 8 302 165 15.4 0 15.7 15.2 05/22/2006 16:30:00 8.7 1.2 13 6.1 8.8 1.2 12.6 6.1 7.4 1.3 11.1 4.6 304 10 303 165 15.5 0.1 16 15.2 05/22/2006 16:40:00 8.3 1 11.1 5.7 8.4 1 11.5 5.7 6.9 1.1 9.9 4.6 304 8 290 165 15.5 0.1 16 15.2 05/22/2006 16:50:00 8.4 0.9 11.5 5.7 8.5 0.9 11.8 5.7 6.7 1 11.5 4.6 301 7 291 165 15.6 0 16 15.2 05/22/2006 17:00:00 8.2 1.2 13 5.3 8.3 1.2 13.3 5.3 7.1 1.3 11.1 4.6 306 10 291 165 15.7 0 16 15.5 05/22/2006 17:10:00 7.9 1 11.8 5.7 8 1 11.8 6.1 6.8 1 9.9 4.6 303 10 283 165 16 0.1 16.3 15.5 05/22/2006 17:20:00 7.6 1 10.3 4.9 7.7 1 10.7 4.9 6.7 1.1 9.9 4.2 300 11 292 165 16.2 0 16.6 16 05/22/2006 17:30:00 6.8 1 10.7 3.8 6.9 1 11.1 4.2 6.2 1.3 10.3 3.4 306 12 314 165 15.8 0 16.3 15.5 05/22/2006 17:40:00 7.8 1 11.1 5.7 8 0.9 11.1 5.7 6.5 1.1 10.7 3.8 301 9 291 165 15.5 0.1 16 15.2 05/22/2006 17:50:00 7.4 1.1 10.7 4.9 7.6 1 10.7 4.9 6.2 1.1 9.1 3.8 303 9 292 165 15.1 0.1 15.7 14.9 05/22/2006 18:00:00 8.3 1 10.7 5.7 8.4 1 10.7 5.7 7 1 9.5 4.2 305 8 307 165 15 0.2 15.5 14.6 05/22/2006 18:10:00 9.6 1.2 13.7 6.1 9.6 1.3 13.7 5.7 8.1 1.2 12.2 5.3 308 6 302 165 14.7 0 14.9 14.6 05/22/2006 18:20:00 10.2 0.8 12.6 7.6 10.2 0.8 12.6 7.2 8.2 1.2 12.2 5.3 307 6 311 165 14.8 0 15.2 14.6 05/22/2006 18:30:00 9.7 1.2 13 6.8 9.8 1.1 13.3 6.8 8 1.1 11.5 4.6 305 6 312 165 14.7 0 14.9 14.6 05/22/2006 18:40:00 9.2 1.2 12.6 5.7 9.3 1.1 11.8 6.1 7.5 1.2 10.7 4.9 303 8 297 165 14.6 0.1 14.9 14.6 05/22/2006 18:50:00 8.7 1.2 12.2 6.1 8.8 1.2 11.8 6.5 7.1 1.1 10.7 4.2 303 8 296 165 14.6 0 15.2 14.4 05/22/2006 19:00:00 8.6 0.8 10.7 6.1 8.6 0.8 10.7 6.5 7.1 0.9 9.5 4.2 305 7 300 165 14.5 0 14.9 14.4 05/22/2006 19:10:00 8.1 1.2 10.7 4.9 8.2 1.1 10.7 5.3 7.1 1 10.3 4.6 310 8 304 165 14.5 0 14.6 14.4 05/22/2006 19:20:00 7.9 1 9.9 4.9 8 1 10.3 5.3 6.8 1 9.5 3.4 310 10 310 165 14.5 0 14.9 14.4 05/22/2006 19:30:00 8.6 1 11.5 5.7 8.7 1 11.8 6.1 7 1.2 9.9 4.9 305 9 296 165 14.2 0.2 14.6 13.8 05/22/2006 19:40:00 9 1.2 13 5.3 9.1 1.2 12.6 4.9 7.4 1 11.5 4.9 303 9 294 165 13.9 0 14.1 13.5 05/22/2006 19:50:00 8.9 1 10.7 4.6 9 0.9 10.7 4.6 7.1 1 10.3 4.6 298 8 296 165 13.7 0.1 14.1 13.5 05/22/2006 20:00:00 8.4 0.9 10.7 5.7 8.6 0.8 11.1 6.1 6.8 0.9 10.3 4.9 300 7 291 165 13.5 0 13.8 13.3 05/22/2006 20:10:00 8.5 1 11.5 5.3 8.6 1 11.5 5.7 6.9 1.1 10.7 3.8 300 7 292 165 13.5 0 13.8 13.3 05/22/2006 20:20:00 8.8 1.1 12.2 5.7 8.9 1.1 11.8 5.7 7.2 1.1 10.7 4.2 300 9 309 165 13.1 0.2 13.5 12.7 05/22/2006 20:30:00 8.8 1.4 12.6 5.7 8.9 1.3 12.6 6.1 7.3 1.3 11.5 4.2 301 8 292 165 12.8 0 13.3 12.2 05/22/2006 20:40:00 9.8 1 11.8 7.2 9.9 1 11.8 7.2 7.7 1.2 11.1 4.9 298 6 287 165 12.5 0 12.7 11.9 05/22/2006 20:50:00 10.5 1 12.6 8 10.5 0.9 12.6 7.6 8 1.1 11.5 5.3 296 5 297 165 12.1 0 12.5 11.9 05/22/2006 21:00:00 9.8 1 12.2 5.7 9.9 1 12.2 6.1 7.4 1 10.7 4.9 297 6 298 165 11.5 0 11.9 11.1 05/22/2006 21:10:00 9.4 1.3 11.8 5.3 9.5 1.3 12.2 5.7 7.3 1.4 11.1 3.8 296 6 294 165 11.3 0.2 11.7 10.9 05/22/2006 21:20:00 9.8 1 12.6 6.8 9.8 1 12.2 6.8 7.6 1.3 11.8 5.3 297 6 290 165 11.1 0.1 11.4 10.9 05/22/2006 21:30:00 9.5 0.9 12.2 6.8 9.6 0.9 11.8 7.2 7.3 1.1 12.6 4.9 297 5 289 165 11.1 0 11.4 10.6 05/22/2006 21:40:00 10 1.1 12.2 6.5 10.1 1.1 12.2 6.5 7.6 1 10.3 4.6 297 5 297 165 11.1 0.1 11.4 10.9 05/22/2006 21:50:00 8.9 0.8 11.1 6.8 9 0.8 10.7 6.5 7.3 1.1 11.1 4.9 294 6 283 165 11 0.1 11.4 10.6 05/22/2006 22:00:00 9.6 0.8 11.5 7.2 9.7 0.8 11.5 7.6 7.2 0.9 10.3 5.3 300 5 300 165 11.1 0 11.4 10.6 05/22/2006 22:10:00 8.7 0.8 10.7 6.5 8.8 0.8 11.1 6.5 6.7 0.8 9.1 4.9 302 6 300 165 11 0 11.4 10.6 05/22/2006 22:20:00 8.8 0.7 10.7 7.2 8.8 0.7 10.3 7.2 6.8 0.8 9.1 4.6 304 6 302 165 10.9 0 11.1 10.3 05/22/2006 22:30:00 8 1 9.9 5.7 8 1 9.9 5.7 6.8 0.8 9.1 4.9 307 8 310 165 11.1 0.1 11.4 10.6 05/22/2006 22:40:00 7.9 0.9 10.3 5.7 7.9 0.9 10.3 5.7 6.7 0.8 9.1 4.6 308 7 300 165 11.1 0 11.4 10.6 05/22/2006 22:50:00 7 0.6 8.8 5.3 7.1 0.6 8.8 5.7 5.9 0.8 7.6 3.8 307 6 304 165 11.1 0.1 11.4 10.9 05/22/2006 23:00:00 6.2 0.8 8.4 3.4 6.3 0.8 8.4 4.2 5.2 0.7 7.2 3 306 6 301 165 11.1 0 11.4 10.9 05/22/2006 23:10:00 6 0.8 8.4 4.2 6 0.8 8.4 4.6 5.2 0.8 7.6 3.4 311 8 309 165 11.1 0 11.4 10.9 05/22/2006 23:20:00 6 0.7 8.4 4.2 6 0.7 8 3.8 5.2 0.8 7.6 3.4 308 11 324 165 11.2 0.1 11.7 10.9 05/22/2006 23:30:00 6.4 0.8 8.8 4.6 6.4 0.8 9.1 4.2 5.1 0.9 8 3 302 8 301 165 11.1 0 11.4 10.9 05/22/2006 23:40:00 6.5 0.8 8.4 4.6 6.5 0.8 8 4.6 5.4 0.8 8 3.4 309 11 293 165 11.1 0 11.4 10.9 05/22/2006 23:50:00 6.3 0.8 8.4 4.6 6.3 0.8 8.4 4.6 5.2 0.6 7.2 3.8 308 8 299 165 11.3 0 11.7 11.1 05/23/2006 00:00:00 6.3 0.7 8 4.6 6.3 0.6 8 4.9 5.7 0.8 8.4 3.4 315 9 319 165 11.3 0 11.4 11.1 05/23/2006 00:10:00 6.2 0.9 8 3.8 6.2 0.9 8 3.4 5.3 0.8 7.6 3 309 9 302 165 11 0 11.4 10.6 05/23/2006 00:20:00 6.2 0.7 8 4.2 6.2 0.7 8 4.6 5.3 0.7 7.2 3.8 312 8 310 165 10.9 0 11.1 10.9 05/23/2006 00:30:00 6.4 0.8 9.5 4.2 6.4 0.8 9.1 4.2 5.4 1 8.4 3.8 311 9 317 165 11.1 0 11.4 10.9 05/23/2006 00:40:00 5.8 0.7 7.6 4.2 5.8 0.7 7.6 4.2 5.5 0.7 7.2 3.4 318 9 316 165 11.4 0.1 11.7 10.9 05/23/2006 00:50:00 5.4 0.6 7.2 4.2 5.5 0.6 7.2 4.2 5.2 0.6 6.8 3.4 318 9 310 165 11.5 0 11.7 11.1 05/23/2006 01:00:00 4.6 0.7 6.5 2.3 4.6 0.7 6.1 2.6 4.3 0.6 6.1 2.6 314 14 305 165 11.4 0.2 11.7 10.9 05/23/2006 01:10:00 4.6 0.7 6.5 2.6 4.6 0.7 6.5 3 4.6 0.7 6.5 2.6 326 13 321 165 11.3 0 11.7 10.9 05/23/2006 01:20:00 4.7 0.7 6.5 2.6 4.7 0.7 6.5 2.6 4.7 0.5 6.5 3.4 335 8 329 165 11.4 0.2 11.7 10.9 05/23/2006 01:30:00 5.5 0.6 6.8 4.2 5.4 0.7 6.8 3 5.4 0.6 7.2 4.2 334 8 338 165 11.2 0.1 11.7 10.9 05/23/2006 01:40:00 5.8 0.7 8.4 4.6 5.9 0.7 8.4 3.8 5.8 0.6 7.6 4.2 338 7 336 165 11.7 0 11.9 11.1 05/23/2006 01:50:00 5.2 0.8 8 3.8 4.9 1 8 2.3 5 0.7 7.6 3.8 344 8 340 165 11.4 0.1 11.7 10.9 05/23/2006 02:00:00 5.4 0.7 7.6 3.8 5.1 0.9 6.8 3 5.3 0.6 7.2 3.8 348 7 357 165 11.3 0 11.7 10.9 05/23/2006 02:10:00 7 0.8 9.5 5.3 5.8 1.2 8.8 3 6.8 0.8 8.8 4.6 353 7 357 165 11.7 0.1 12.2 11.1 05/23/2006 02:20:00 6.5 0.8 8.4 4.2 6 1.3 8.8 2.6 6.4 0.7 8 4.6 350 6 342 165 11.8 0.1 11.9 11.4 05/23/2006 02:30:00 7.1 0.9 9.5 4.6 5.7 1.2 8.8 3 7 0.9 9.5 4.6 354 7 360 165 11.9 0.1 12.2 11.7 05/23/2006 02:40:00 7.1 1 9.5 4.6 5.8 1.7 10.3 2.3 6.9 1 9.5 4.9 352 7 358 165 12.3 0 12.5 11.9 05/23/2006 02:50:00 6.9 0.7 8.8 5.3 5.4 1.1 8 2.6 6.9 0.8 9.5 4.9 356 8 357 165 12.1 0 12.2 11.7 05/23/2006 03:00:00 6.1 0.8 8.4 4.6 4.4 1 7.6 1.9 6.2 0.8 8.4 4.6 358 6 4 165 12.1 0.1 12.5 11.7 05/23/2006 03:10:00 6.6 1.1 10.3 4.2 5.5 1.4 9.1 2.6 6.3 1.1 9.9 4.6 353 8 1 165 11.7 0 11.9 11.1 05/23/2006 03:20:00 6.1 0.8 8.4 4.2 5.1 1.2 8 2.6 6 0.9 8.4 3.8 352 8 358 165 11.7 0.1 11.9 10.9 05/23/2006 03:30:00 6.6 1 9.1 4.2 6.1 1 8.8 3.4 6.5 1 8.8 4.6 344 10 353 165 11.4 0 11.7 10.9 05/23/2006 03:40:00 7.7 1 10.7 4.6 6 1.3 10.3 3.4 7.7 1 11.1 4.9 356 6 357 165 11.7 0 11.9 11.4 05/23/2006 03:50:00 8.3 1 11.1 6.1 7.5 1.6 11.1 3.8 8.3 1 11.1 5.3 351 7 6 165 11.7 0.1 11.9 11.4 05/23/2006 04:00:00 8.4 0.9 11.1 6.5 6.6 1.6 10.7 3.8 8.5 0.8 11.1 6.5 355 6 352 165 11.7 0 12.2 11.4 05/23/2006 04:10:00 8.7 1 11.8 6.5 7 1.5 11.5 4.2 8.8 1 11.8 6.5 355 6 7 165 11.5 0 11.7 10.9 05/23/2006 04:20:00 8.2 0.9 11.1 6.5 7.6 1.1 10.7 4.6 8.2 0.9 11.8 5.7 347 8 3 165 11.3 0 11.7 11.1 05/23/2006 04:30:00 8.7 0.6 10.7 6.8 8 1.3 11.1 3.8 8.4 0.6 10.7 6.8 349 7 344 165 11.3 0 11.4 11.1 05/23/2006 04:40:00 8.2 0.7 9.9 6.5 7.8 1 9.9 4.6 8.4 0.7 9.9 6.8 348 6 351 165 11.1 0 11.4 11.1 05/23/2006 04:50:00 7.3 1 9.9 4.6 6.8 1.3 9.5 3.4 7.3 0.8 9.1 5.3 347 9 349 165 11.2 0 11.4 11.1 05/23/2006 05:00:00 8 1.2 10.7 4.9 6.8 1.1 9.9 3.8 8.1 1.2 11.1 5.7 351 7 357 165 11.3 0.1 11.7 11.1 05/23/2006 05:10:00 9.4 1.2 13 7.2 8.3 1.6 13.3 4.9 9.4 1.1 12.2 6.8 348 10 343 165 11.7 0.1 11.9 11.1 05/23/2006 05:20:00 9.3 1.2 12.6 7.2 8.3 1.4 11.5 4.9 9.3 1.2 12.2 6.5 349 9 9 165 11.7 0.1 11.9 11.4 05/23/2006 05:30:00 9.7 1 12.6 6.8 8.2 1.5 11.5 4.6 9.8 1 12.6 6.8 353 7 359 165 11.9 0 11.9 11.4 05/23/2006 05:40:00 9.8 0.8 11.8 7.2 7.9 1.5 11.5 4.6 10 0.8 12.2 8.4 353 6 350 165 11.9 0 12.2 11.7 05/23/2006 05:50:00 9.4 1 11.8 7.6 8 1.8 12.6 4.2 9.6 0.8 12.2 8 351 9 337 165 12.3 0.1 12.7 11.7 05/23/2006 06:00:00 10 0.7 11.8 8.4 7.7 1.6 11.5 4.6 10.1 0.8 11.8 8.4 354 5 354 165 12.5 0 12.7 12.2 05/23/2006 06:10:00 9.7 0.8 12.2 8 7.3 1.6 11.5 4.2 9.9 0.8 11.8 8 356 7 4 165 12.7 0 13 12.5 05/23/2006 06:20:00 9.6 0.8 12.6 7.2 7.7 1.5 11.5 4.6 9.9 0.9 12.6 7.6 352 7 354 165 12.9 0 13 12.7 05/23/2006 06:30:00 8.8 0.6 10.7 7.2 7.6 1.5 10.7 4.2 8.8 0.7 10.7 6.8 350 8 348 165 12.7 0 13 12.5 05/23/2006 06:40:00 8.5 1 11.8 6.5 7.9 1.5 11.5 3.8 8.5 0.9 10.7 6.1 345 9 332 165 12.5 0 12.7 12.5 05/23/2006 06:50:00 7.9 0.8 9.9 5.7 7.7 1 10.3 4.6 7.9 0.8 10.3 5.7 343 8 346 165 12.7 0 13 12.5 05/23/2006 07:00:00 7.6 0.8 9.5 5.7 7.1 1.2 9.5 3.8 7.8 0.8 9.9 5.7 345 8 351 165 13.1 0 13.3 12.7 05/23/2006 07:10:00 7 0.7 8.4 5.3 6.4 1 8.4 3.4 7.2 0.8 9.1 5.7 349 6 354 165 13.4 0 13.5 12.7 05/23/2006 07:20:00 6.3 0.7 8.4 4.6 6.1 0.9 8.4 3 6.5 0.8 8.8 4.9 348 6 354 165 13.7 0.1 14.1 13.3 05/23/2006 07:30:00 5 0.6 6.8 3.4 3.8 1 6.1 1.9 4.9 0.7 6.8 3 357 9 2 165 14.6 0.4 15.2 14.1 05/23/2006 07:40:00 4.7 0.6 6.1 2.6 4.2 0.9 6.1 2.3 4.6 0.6 6.5 3 357 13 25 165 15.2 0 15.5 15.2 05/23/2006 07:50:00 5.3 0.7 7.2 3.4 4.3 1 6.8 2.3 5.2 0.8 7.2 3 353 10 10 165 15.2 0 15.5 15.2 05/23/2006 08:00:00 5.1 0.8 6.5 3 4.1 1 6.1 1.9 5 0.7 6.8 3.4 6 10 351 165 15.4 0 15.7 15.2 05/23/2006 08:10:00 6.1 0.7 8 4.2 5 1.1 7.6 2.3 6.2 0.7 8.4 4.6 9 11 12 165 15.3 0 15.7 15.2 05/23/2006 08:20:00 6.2 0.8 8.4 4.6 5.1 1.1 7.6 2.3 6.2 0.8 8.4 4.6 359 11 15 165 15.6 0.1 16 15.2 05/23/2006 08:30:00 5.7 0.7 7.6 3.8 4.4 1 7.6 2.3 5.7 0.8 8 3.4 8 9 25 165 15.9 0 16 15.7 05/23/2006 08:40:00 5 0.8 7.6 3.4 4.1 1 7.2 1.9 5 0.8 6.8 3 10 12 26 165 15.9 0 16.3 15.7 05/23/2006 08:50:00 5.7 0.6 7.6 3.8 5.4 0.8 7.6 3 5.6 0.8 8 3.8 22 9 27 165 15.6 0.1 16.3 15.5 05/23/2006 09:00:00 5.8 0.8 7.6 3.4 5.7 0.8 8 3.4 5.6 0.9 8 3.4 33 12 38 165 15.5 0.2 16.3 14.9 05/23/2006 09:10:00 6.3 0.8 8 4.2 6.3 0.8 8.4 3.8 6.3 0.8 8.8 3.8 32 8 34 165 15.1 0.1 15.7 14.9 05/23/2006 09:20:00 6.1 0.8 8.8 4.2 6 0.8 8.8 3.8 5.9 1 8.8 3.4 33 9 29 165 15.1 0 15.7 14.9 05/23/2006 09:30:00 6.1 0.8 8 4.2 6.1 0.8 8 3.8 5.9 0.8 8 3.8 32 10 46 165 15.2 0 15.7 14.9 05/23/2006 09:40:00 7.2 0.7 8.8 4.6 7.1 0.8 9.1 4.6 7.1 0.9 9.9 4.6 27 7 29 165 15 0 15.5 14.9 05/23/2006 09:50:00 7.7 0.6 9.5 5.7 7.6 0.7 9.5 5.3 7.8 0.7 9.9 5.7 27 6 30 165 14.5 0.1 15.2 14.1 05/23/2006 10:00:00 7.2 0.6 8.8 5.3 7 0.8 8.8 4.6 7.3 0.7 9.1 5.3 24 7 31 165 14.3 0 14.6 14.4 05/23/2006 10:10:00 7.2 0.6 8.8 4.9 6.9 0.8 8.8 3.8 7.4 0.6 9.1 5.3 21 6 12 165 14.2 0 14.6 14.1 05/23/2006 10:20:00 7.6 0.6 8.8 5.7 7.1 0.7 8.4 4.2 7.7 0.7 9.1 4.9 18 5 17 165 14 0 14.6 13.8 05/23/2006 10:30:00 7.5 0.4 8.4 5.7 7.4 0.5 8 5.7 7.3 0.6 8.4 5.7 25 4 23 165 13.9 0.1 14.4 13.8 05/23/2006 10:40:00 7.1 0.7 8.4 5.3 7.1 0.7 8.4 5.3 7.3 0.6 8.4 5.3 30 4 32 165 13.7 0 14.4 13.5 05/23/2006 10:50:00 5.2 0.6 6.5 3 5.3 0.6 6.5 2.6 5.3 0.7 6.8 3.4 46 7 40 165 13.9 0.1 14.4 13.5 05/23/2006 11:00:00 6.2 0.6 7.2 4.6 6.3 0.6 7.2 4.6 6.5 0.7 7.6 4.2 34 4 35 165 13.5 0.1 14.1 13.3 05/23/2006 11:10:00 6 0.4 6.8 4.6 6.1 0.4 6.8 4.2 6.4 0.5 7.2 4.6 33 5 34 165 13.4 0 13.5 13.3 05/23/2006 11:20:00 6.3 0.4 7.2 5.3 6.4 0.3 7.2 5.7 6.7 0.5 7.6 5.3 32 3 37 165 13.1 0 13.5 13 05/23/2006 11:30:00 6.3 0.3 7.2 5.3 6.2 0.4 7.2 5.3 6.7 0.3 7.6 5.3 24 4 24 165 13.2 0 13.5 13 05/23/2006 11:40:00 5.7 0.5 6.8 4.2 5.8 0.5 6.8 4.6 6 0.5 7.2 3.8 31 5 28 165 14 0.3 14.9 13.5 05/23/2006 11:50:00 4.9 0.6 6.1 3 4.9 0.6 6.1 2.6 5.1 0.6 6.5 3.4 37 7 48 165 15 0.3 16 14.6 05/23/2006 12:00:00 5 0.7 6.5 3 5 0.6 6.5 3 5 0.8 6.8 3 38 9 40 165 15.5 0.2 16 15.2 05/23/2006 12:10:00 6.1 0.5 6.8 4.6 6.1 0.5 7.2 4.2 6.1 0.7 7.2 3.8 37 5 26 165 14.8 0.2 15.5 14.4 05/23/2006 12:20:00 5 0.7 6.1 2.6 4.9 0.8 6.5 2.6 4.7 1 6.5 2.3 38 8 34 165 14.8 0.4 15.7 14.4 05/23/2006 12:30:00 4.7 0.6 5.7 2.6 4.6 0.7 6.1 2.6 4.3 0.7 6.1 1.9 40 7 45 165 15.6 0 16 15.5 05/23/2006 12:40:00 3.4 0.8 5.3 0.4 3.4 0.9 5.3 0.7 3.2 1 5.3 0.4 48 22 44 165 15.9 0.6 16.8 15.2 05/23/2006 12:50:00 3.4 0.6 4.6 2.3 3.5 0.6 4.9 1.9 3.1 0.6 4.6 1.9 44 12 44 165 16.3 0.1 16.8 16 05/23/2006 13:00:00 2.2 0.8 4.6 0.4 2.2 0.8 4.6 0.4 2.1 0.9 4.2 0.4 101 51 60 165 16.9 0.2 17.4 16.3 05/23/2006 13:10:00 1.9 0.8 4.6 0.4 1.9 0.8 4.6 0.4 1.9 0.8 3.8 0.4 101 45 122 165 17 0.2 17.7 16.6 05/23/2006 13:20:00 1.8 1 4.6 0.4 1.8 1 4.6 0.4 1.8 0.8 4.2 0.4 100 69 26 165 17.8 0 18 17.4 05/23/2006 13:30:00 2 1 5.3 0.4 1.9 0.9 4.9 0.4 1.8 0.9 4.6 0.4 81 53 77 165 17.5 0.2 17.7 16.8 05/23/2006 13:40:00 1.5 0.8 3.8 0.4 1.5 0.8 3.4 0.4 1.5 0.8 3.4 0.4 96 69 39 165 17.4 0 17.7 17.1 05/23/2006 13:50:00 2.8 0.8 4.6 0.4 2.7 0.9 5.3 0.4 2.4 0.9 4.9 0.4 53 30 80 165 17.8 0 18 17.4 05/23/2006 14:00:00 3.1 1 5.7 0.4 3.1 1 6.5 0.7 2.9 1 5.7 0.4 53 27 66 165 17.7 0.3 18.2 17.1 05/23/2006 14:10:00 3.7 0.6 4.9 1.9 3.7 0.6 5.3 1.5 3.7 0.7 4.9 1.9 44 10 54 165 17 0 17.4 16.8 05/23/2006 14:20:00 3.7 0.5 4.9 2.3 3.7 0.4 4.9 2.3 3.7 0.6 5.3 1.9 43 9 42 165 17.2 0.1 17.4 16.8 05/23/2006 14:30:00 3.4 0.4 4.9 2.6 3.4 0.4 4.6 2.6 3.5 0.4 4.9 2.3 34 7 39 165 17.4 0.1 18 16.8 05/23/2006 14:40:00 3.2 0.4 4.2 1.9 3.2 0.5 4.2 1.9 3.2 0.4 4.6 1.9 33 10 37 165 17.8 0 18 17.1 05/23/2006 14:50:00 3 0.6 4.2 0.4 3 0.5 4.2 0.7 3 0.6 4.6 0.7 40 14 28 165 17.9 0 18.2 17.1 05/23/2006 15:00:00 3.4 0.6 4.9 2.3 3.4 0.6 4.6 2.3 3.4 0.7 4.9 1.9 36 12 25 165 17.8 0 18.2 17.4 05/23/2006 15:10:00 3.7 0.4 4.9 3 3.7 0.4 4.9 2.6 3.7 0.5 4.9 2.6 34 8 29 165 17.7 0.2 18.2 17.1 05/23/2006 15:20:00 3.4 0.5 4.6 2.3 3.4 0.4 4.6 2.3 3.4 0.5 4.9 1.9 41 8 41 165 17.6 0.1 18.2 17.1 05/23/2006 15:30:00 3.7 0.5 4.9 2.3 3.7 0.5 4.6 2.3 3.7 0.5 5.3 2.6 31 8 45 165 18 0 18.5 17.7 05/23/2006 15:40:00 3.5 0.4 4.9 2.6 3.5 0.4 4.9 2.3 3.6 0.4 4.9 2.3 29 9 31 165 18.3 0.2 18.5 18 05/23/2006 15:50:00 3.4 0.5 4.6 2.3 3.3 0.5 4.9 2.3 3.5 0.5 4.9 1.9 28 10 37 165 18.5 0 18.8 18 05/23/2006 16:00:00 3.9 0.4 5.3 2.6 3.5 0.6 4.9 1.9 3.9 0.5 5.3 2.6 18 11 15 165 17.9 0.1 18.2 17.4 05/23/2006 16:10:00 3.9 0.5 5.7 2.6 3.4 0.6 5.3 1.9 3.9 0.5 5.3 2.6 13 9 11 165 18.4 0.1 18.5 18 05/23/2006 16:20:00 4 0.5 5.7 2.6 3 0.6 4.6 1.5 4.1 0.5 5.3 2.6 8 8 357 165 18.6 0 19.1 18.5 05/23/2006 16:30:00 3.8 0.5 5.3 2.6 3 0.7 4.6 1.5 3.8 0.5 5.3 2.3 5 9 4 165 19 0 19.4 18.8 05/23/2006 16:40:00 3.9 0.5 5.7 2.6 3.2 0.6 5.3 1.9 3.9 0.5 5.7 2.3 1 10 355 165 19.5 0.1 20 19.1 05/23/2006 16:50:00 3.5 0.4 4.9 2.3 3 0.6 4.6 1.9 3.5 0.4 4.9 2.6 358 12 12 165 19.5 0 19.7 19.1 05/23/2006 17:00:00 3.7 0.4 4.9 2.6 2.8 0.6 4.6 1.5 3.7 0.4 4.9 2.6 2 8 353 165 19.5 0 20 19.4 05/23/2006 17:10:00 3.7 0.5 4.9 2.6 3.1 0.6 4.6 1.5 3.6 0.5 4.9 2.6 355 8 353 165 19.5 0.2 20 19.1 05/23/2006 17:20:00 3.6 0.5 5.3 2.3 3.4 0.6 5.3 1.9 3.6 0.5 4.9 2.6 348 7 343 165 19.8 0 20.2 19.7 05/23/2006 17:30:00 3.6 0.4 4.6 2.3 3.2 0.6 4.6 1.5 3.6 0.4 4.6 2.6 350 12 359 165 20.2 0 20.5 20 05/23/2006 17:40:00 3.2 0.5 4.6 1.5 2.7 0.7 4.2 0.7 3.2 0.7 4.6 1.1 353 14 351 165 19.8 0.2 20.2 19.7 05/23/2006 17:50:00 3 0.6 4.6 1.9 2.6 0.6 4.2 1.1 2.9 0.6 4.2 1.5 351 14 329 165 19.6 0 20 19.4 05/23/2006 18:00:00 2.4 0.5 3.4 1.1 2.2 0.5 3.4 0.7 2.4 0.5 3.8 0.7 348 13 4 165 19.6 0 20 19.7 05/23/2006 18:10:00 2.7 0.5 4.2 1.5 2.4 0.5 3.8 1.5 2.6 0.5 3.8 1.1 348 10 354 165 19.9 0 20.2 19.7 05/23/2006 18:20:00 2.7 0.4 3.8 1.5 2.5 0.5 3.8 1.1 2.5 0.4 3.8 1.5 335 14 330 165 19.2 0.7 20 17.7 05/23/2006 18:30:00 2.5 0.3 3 1.9 2.5 0.3 3.4 1.5 2.5 0.3 3.4 1.9 338 9 331 165 18 0.2 18.5 17.7 05/23/2006 18:40:00 2.3 0.5 3.4 1.1 1.9 0.5 3.4 0.7 2.4 0.4 3.4 1.1 360 9 346 165 18.5 0 18.8 18.2 05/23/2006 18:50:00 1.6 0.3 2.3 0.7 1.4 0.4 2.3 0.7 1.8 0.4 2.6 0.7 353 11 15 165 18.9 0 19.1 18.5 05/23/2006 19:00:00 1.6 0.4 2.6 0.7 1.4 0.5 2.6 0.4 1.6 0.4 3 0.7 344 11 328 165 18.2 0 18.5 18 05/23/2006 19:10:00 1.3 0.3 2.3 0.7 1.2 0.3 2.3 0.7 1.2 0.5 2.6 0.4 338 8 357 165 17.8 0 18.2 17.4 05/23/2006 19:20:00 1.4 0.3 2.3 0.4 1.3 0.3 1.9 0.7 1.2 0.4 2.3 0.4 335 6 339 165 18.3 0 18.5 18 05/23/2006 19:30:00 1.5 0.4 2.6 0.7 1.4 0.4 2.3 0.4 1.4 0.4 2.3 0.4 344 9 3 165 18.4 0 18.5 18 05/23/2006 19:40:00 2.2 0.5 3 1.1 1.9 0.5 3 0.7 2 0.5 3 1.1 348 7 346 165 18.3 0 18.5 18.2 05/23/2006 19:50:00 2.2 0.3 3 1.5 2.1 0.4 3.4 1.1 2.1 0.3 3 1.1 338 7 343 165 18 0 18.2 17.7 05/23/2006 20:00:00 3.1 0.5 4.6 2.3 2.9 0.5 4.2 1.5 3 0.5 4.6 1.9 345 7 352 165 17.6 0 18 17.4 05/23/2006 20:10:00 3.5 0.4 4.6 2.6 3.2 0.6 4.6 1.5 3.2 0.4 4.6 2.3 349 6 349 165 17.4 0 17.7 17.1 05/23/2006 20:20:00 3.6 0.4 4.6 2.6 3.2 0.6 4.6 1.5 3.4 0.4 4.6 2.3 350 6 344 165 17 0 17.4 16.8 05/23/2006 20:30:00 3.6 0.4 4.6 2.6 2.9 0.7 4.6 1.1 3.5 0.4 4.6 2.3 354 6 347 165 16.7 0 16.8 16.6 05/23/2006 20:40:00 3.6 0.5 4.9 2.6 3.2 0.7 4.9 1.5 3.3 0.5 4.6 2.3 348 7 349 165 16.3 0.1 16.6 16 05/23/2006 20:50:00 4.5 0.5 6.1 3.4 4.3 0.6 5.7 2.6 4.2 0.4 5.3 3 343 9 337 165 15.7 0 16.3 15.5 05/23/2006 21:00:00 4.3 0.7 6.1 3 4 0.9 6.5 1.9 3.8 0.6 6.1 2.6 343 10 351 165 15 0.3 15.7 14.6 05/23/2006 21:10:00 4.1 0.6 5.7 2.6 3.8 0.8 5.7 1.5 3.4 0.7 5.7 1.5 344 10 332 165 14.2 0.2 14.6 13.5 05/23/2006 21:20:00 4.4 0.7 6.8 1.9 4.1 0.9 6.5 1.5 3.8 0.7 6.5 1.5 341 11 344 165 13.9 0 14.4 13.3 05/23/2006 21:30:00 5.3 0.9 8 2.6 5.2 0.9 7.6 1.9 4.8 0.8 7.2 2.6 334 12 333 165 13.9 0.1 14.4 13.3 05/23/2006 21:40:00 5 1.2 8.8 2.6 4.7 1.3 8.4 2.3 4.6 1 7.6 3 338 12 325 165 14.4 0 14.6 13.8 05/23/2006 21:50:00 5.9 1 8.4 3.4 5.8 1.1 8.8 3.8 5.5 0.8 7.6 3.4 338 9 347 165 14.4 0 14.6 14.1 05/23/2006 22:00:00 6.1 0.8 8 4.6 6 0.9 8.4 3.8 5.8 0.9 8.4 4.2 338 8 334 165 14.6 0 14.9 13.8 05/23/2006 22:10:00 5.1 0.9 7.2 3 5 1 7.2 1.9 5 0.8 6.8 2.6 340 8 328 165 14.7 0 14.9 14.6 05/23/2006 22:20:00 4.2 0.5 5.7 3 3.8 0.6 5.3 2.3 4.1 0.5 5.7 3 348 8 350 165 14.6 0 15.2 14.1 05/23/2006 22:30:00 5.1 0.6 6.8 3.8 5 0.6 6.5 3.4 4.9 0.6 6.8 3.8 340 6 335 165 14.3 0 14.6 14.1 05/23/2006 22:40:00 4.7 0.5 6.1 3.8 4.4 0.9 5.7 1.9 4.7 0.5 5.7 3.4 345 8 334 165 14.4 0 14.6 14.4 05/23/2006 22:50:00 5.4 0.5 7.6 3.8 5.1 0.8 7.2 2.6 5.4 0.5 6.5 4.2 345 8 321 165 14.4 0 14.6 14.4 05/23/2006 23:00:00 5.3 0.8 8 3.8 5.2 0.9 8 2.6 5.3 0.7 7.2 4.2 339 8 334 165 14.6 0 14.9 14.6 05/23/2006 23:10:00 5.1 0.6 7.2 3.8 5 0.8 7.2 2.3 5.1 0.6 6.8 3.8 341 10 344 165 14.7 0 15.2 14.6 05/23/2006 23:20:00 6 0.7 8 4.2 5.4 1.1 8 2.6 6 0.8 8.4 3.8 349 9 328 165 14.6 0 15.2 14.4 05/23/2006 23:30:00 6 0.7 9.1 4.2 5.7 1.1 9.9 2.6 5.8 0.8 8.4 3.8 345 8 342 165 14.4 0 14.9 14.1 05/23/2006 23:40:00 5.9 0.6 7.6 4.6 5.2 1 8 3 6.1 0.6 8 4.6 350 8 357 165 14.1 0 14.4 13.8 05/23/2006 23:50:00 6.5 0.7 8.8 4.9 6.4 0.8 8.8 4.2 6.6 0.7 8.4 4.6 342 7 344 165 14 0 14.4 13.3 05/24/2006 00:00:00 7.7 0.8 9.9 5.7 7.6 0.9 9.9 4.6 7.5 0.8 10.3 5.3 338 8 329 165 14.2 0.1 14.6 13.8 05/24/2006 00:10:00 7.1 1 10.3 4.6 7.2 1 9.9 4.9 7 1 9.5 4.6 338 7 332 165 14.3 0.1 14.6 13.8 05/24/2006 00:20:00 6.8 0.9 9.9 5.3 6.7 1.2 9.9 3 6.9 0.9 9.9 4.9 341 9 339 165 14.2 0.2 14.6 13.8 05/24/2006 00:30:00 7.9 1.1 10.7 5.3 7.9 1 10.3 5.3 7.7 1 10.3 5.7 337 9 326 165 14.4 0 14.9 13.8 05/24/2006 00:40:00 7.7 1.2 10.3 5.3 7.5 1.3 10.3 4.2 7.7 1.1 9.9 5.3 340 10 339 165 14.2 0 14.6 14.1 05/24/2006 00:50:00 8 1 11.5 5.7 7.9 1.1 11.1 4.6 7.8 0.9 10.3 5.7 339 9 336 165 14.5 0 14.9 14.4 05/24/2006 01:00:00 7.5 1.2 11.1 4.9 7.3 1.5 11.5 3.4 7.2 1.1 10.7 5.3 342 10 344 165 14.4 0 14.6 14.1 05/24/2006 01:10:00 8 1 11.5 5.3 7.3 1.6 11.5 3 7.8 1 9.9 5.7 346 9 337 165 14.2 0 14.6 14.1 05/24/2006 01:20:00 7.3 1 9.5 4.9 6.4 1.3 9.1 3 7.4 0.8 9.9 5.3 350 8 358 165 14.2 0 14.9 14.1 05/24/2006 01:30:00 7.6 1 10.3 5.3 6.4 1.3 11.1 3.4 7.5 1 9.9 4.9 351 8 345 165 14.2 0 14.6 14.1 05/24/2006 01:40:00 7.2 0.9 9.9 4.9 5.6 1.2 9.9 3.4 7.2 0.9 9.5 4.9 354 8 357 165 14.1 0.1 14.6 13.8 05/24/2006 01:50:00 8.1 1 11.1 5.7 6.3 1.1 9.5 3.8 8.3 1 11.1 6.1 354 8 3 165 14.2 0 14.4 13.8 05/24/2006 02:00:00 7.5 1 9.9 5.3 7.3 1.1 10.3 4.2 7.5 0.9 9.9 5.7 341 9 354 165 14.2 0 14.4 14.1 05/24/2006 02:10:00 7.4 0.8 10.3 5.3 6.5 1.5 9.9 2.3 7.6 0.8 9.5 5.3 350 9 331 165 14.1 0 14.6 13.8 05/24/2006 02:20:00 6.8 1 9.9 4.6 5.8 1.3 9.1 2.6 6.9 1 9.9 4.9 350 11 354 165 14.1 0 14.4 13.8 05/24/2006 02:30:00 6.7 0.9 9.1 5.3 6.3 1.3 9.9 3.4 6.8 0.8 9.5 5.3 348 8 350 165 13.9 0 14.4 13.5 05/24/2006 02:40:00 7.9 0.9 9.9 5.3 6.8 1.5 9.9 3 7.8 1 10.3 4.9 350 7 358 165 13.9 0 14.1 13.8 05/24/2006 02:50:00 7.1 0.7 9.9 4.9 6.8 1 9.5 3.8 7.3 0.6 9.1 5.3 347 7 358 165 13.9 0 14.4 13.5 05/24/2006 03:00:00 7.1 0.7 9.1 4.9 6.7 1.2 9.1 3.4 7.2 0.8 9.1 4.9 347 7 334 165 13.8 0 14.1 13.5 05/24/2006 03:10:00 7 0.7 8.8 4.9 6.5 1.3 8.8 3.4 7.1 0.6 8.8 5.3 348 8 343 165 13.8 0 14.1 13.5 05/24/2006 03:20:00 7.3 0.9 10.3 5.7 7 1 10.3 4.2 7.3 0.8 9.5 5.3 347 6 335 165 13.7 0.1 14.1 13.3 05/24/2006 03:30:00 7.4 0.8 10.3 5.7 7.1 1.2 10.3 3.4 7.4 0.7 9.9 5.7 345 8 339 165 13.7 0 13.8 13.5 05/24/2006 03:40:00 6.7 0.7 8.4 4.9 5.7 1.5 8.8 2.6 6.7 0.8 9.1 4.6 351 9 357 165 13.4 0 13.8 13.3 05/24/2006 03:50:00 7.3 0.8 9.5 5.3 7.4 0.9 9.9 4.9 7.3 0.8 9.9 5.7 341 7 341 165 13.4 0 13.5 13.3 05/24/2006 04:00:00 7.7 0.7 9.1 6.1 7.8 0.7 9.5 5.7 7.7 0.7 9.1 5.7 341 6 349 165 13.7 0 13.8 13.3 05/24/2006 04:10:00 6.9 0.7 8.8 5.3 7 0.8 9.1 3.4 7 0.6 8.8 5.3 342 7 333 165 13.3 0 13.8 13 05/24/2006 04:20:00 8.1 1 10.7 5.7 8.2 1 11.1 4.9 8 1.1 10.7 5.7 338 6 342 165 13.3 0.2 13.8 12.7 05/24/2006 04:30:00 7.9 1 10.7 5.3 7.9 1 10.7 4.2 7.8 1 10.7 5.3 338 7 333 165 13.8 0 14.1 13.3 05/24/2006 04:40:00 7.1 0.8 9.1 5.3 7.2 0.7 9.1 4.9 7.1 0.7 9.1 5.3 339 5 341 165 13.6 0 13.8 13.3 05/24/2006 04:50:00 5.7 0.6 8 4.2 5.1 1.1 8 2.3 5.8 0.6 7.2 4.2 349 9 350 165 13.4 0 14.1 13 05/24/2006 05:00:00 5.1 0.8 7.2 3 3.6 0.8 6.8 1.9 5.2 0.9 6.8 3.4 1 10 4 165 13.3 0.1 13.8 13 05/24/2006 05:10:00 4.4 0.5 6.1 3 3.2 0.7 5.7 1.5 4.5 0.6 5.7 3.4 3 9 19 165 13.9 0 14.1 13.8 05/24/2006 05:20:00 4.6 0.5 6.1 3.4 3.2 0.8 4.9 1.5 4.7 0.6 6.5 3.4 354 5 359 165 14.2 0 14.6 14.1 05/24/2006 05:30:00 5.3 0.4 6.5 4.2 4 0.8 6.5 2.3 5.4 0.5 6.8 4.2 353 6 1 165 14.4 0 14.6 14.4 05/24/2006 05:40:00 4.9 0.4 6.1 3.8 3.6 1.1 6.1 1.5 4.8 0.4 5.7 3.8 353 8 336 165 14.7 0 14.9 14.6 05/24/2006 05:50:00 4.1 0.8 5.7 1.9 2.8 1.1 5.7 0.7 3.9 0.9 5.3 1.5 358 9 346 165 15.1 0.2 15.5 14.9 05/24/2006 06:00:00 3.1 0.4 4.2 2.3 2.2 0.6 3.8 1.1 3.3 0.4 4.2 2.3 11 8 15 165 15.7 0 16 15.5 05/24/2006 06:10:00 3.1 0.4 3.8 1.9 2 0.6 3.4 0.4 3.1 0.4 4.2 2.3 8 8 359 165 16 0.1 16.6 15.2 05/24/2006 06:20:00 2.2 0.6 3.8 0.7 1.7 0.5 3 0.4 2 0.9 3.8 0.4 26 20 8 165 16.4 0 16.8 16.3 05/24/2006 06:30:00 2.2 0.5 4.2 1.1 2 0.5 3.8 0.7 2.1 0.5 4.2 1.1 35 7 39 165 16.2 0.1 16.8 16.3 05/24/2006 06:40:00 2.6 0.6 4.2 1.5 2.3 0.7 4.2 0.7 2.7 0.5 4.2 1.5 22 11 25 165 16.4 0.1 16.8 16.3 05/24/2006 06:50:00 2.4 0.7 4.2 0.4 2.1 0.8 4.2 0.4 2.2 0.7 3.8 0.7 29 8 26 165 16.9 0 17.1 16.8 05/24/2006 07:00:00 4.3 0.4 5.3 3 3.1 0.8 4.6 1.5 4 0.5 5.3 2.3 8 7 10 165 17.1 0 17.4 16.8 05/24/2006 07:10:00 4.1 0.6 5.7 3 3 1.1 5.7 1.5 3.8 0.5 5.3 2.6 357 8 354 165 17 0.1 17.4 16.8 05/24/2006 07:20:00 3.5 1 5.3 1.5 2.9 1 5.3 1.1 3.2 1 5.3 0.4 358 10 352 165 17.4 0 17.7 17.1 05/24/2006 07:30:00 1.7 0.5 3.4 0.4 1.5 0.6 3 0.4 1.4 0.6 3 0.4 16 12 14 165 17.9 0.1 18.2 17.7 05/24/2006 07:40:00 0.7 0.4 1.9 0.4 0.6 0.4 1.9 0.4 0.5 0.2 1.5 0.4 58 58 30 165 18 0.1 18.2 17.7 05/24/2006 07:50:00 0.6 0.4 1.9 0.4 0.7 0.4 1.9 0.4 0.6 0.4 1.9 0.4 351 76 291 165 18.5 0.2 18.8 18 05/24/2006 08:00:00 1.1 0.5 2.6 0.4 1.1 0.5 2.6 0.4 1.1 0.5 2.3 0.4 345 32 339 165 18.6 0.2 19.1 18.2 05/24/2006 08:10:00 1 0.5 2.6 0.4 1 0.6 2.6 0.4 1 0.5 2.3 0.4 48 41 90 165 18.5 0 18.8 18.2 05/24/2006 08:20:00 1.4 0.6 3 0.4 1.3 0.6 2.6 0.4 1.1 0.6 2.3 0.4 36 28 112 165 19 0 19.4 18.8 05/24/2006 08:30:00 1.9 0.5 3.4 0.7 1.6 0.5 3.4 0.7 1.8 0.5 3.4 0.4 6 15 357 165 19.3 0.1 19.7 18.8 05/24/2006 08:40:00 2.2 0.7 4.6 0.4 2.2 0.7 4.2 0.4 2 0.8 3.8 0.4 100 33 129 165 18.2 0.7 19.7 17.4 05/24/2006 08:50:00 1.7 0.6 3.4 0.4 1.7 0.5 3 0.4 1.8 0.5 3 0.4 140 19 142 165 16.9 0.3 17.4 16.6 05/24/2006 09:00:00 0.8 0.6 2.3 0.4 0.8 0.6 2.3 0.4 0.9 0.7 3 0.4 41 107 141 165 17.2 0.4 18.5 16.6 05/24/2006 09:10:00 1.5 0.9 4.2 0.4 1.5 0.9 3.8 0.4 1.2 0.8 3.4 0.4 83 35 36 165 17.2 0.6 18.5 16.3 05/24/2006 09:20:00 1.7 0.6 3.8 0.4 1.7 0.6 4.2 0.4 1.7 0.4 3 0.7 112 38 49 165 17.2 0.4 17.7 16.3 05/24/2006 09:30:00 1.2 0.8 2.6 0.4 1.1 0.7 3 0.4 1.1 0.8 3.4 0.4 111 98 17 165 17.5 1 18.8 16 05/24/2006 09:40:00 1.3 0.8 3 0.4 1.1 0.6 2.6 0.4 1.1 0.6 3 0.4 333 107 355 165 18.8 0.4 20.2 18.5 05/24/2006 09:50:00 2.4 0.5 3.4 1.1 2 0.5 3.8 0.7 2.2 0.5 3.4 1.1 3 14 351 165 19.9 0 20.2 19.7 05/24/2006 10:00:00 2.2 0.5 3.4 0.7 1.9 0.5 3.4 0.7 2 0.5 3 0.4 356 17 350 165 19.8 0 20.2 19.7 05/24/2006 10:10:00 0.9 0.5 2.3 0.4 0.9 0.5 2.6 0.4 0.9 0.6 2.3 0.4 44 72 29 165 19.7 0.2 20.2 18.8 05/24/2006 10:20:00 1.2 0.5 2.3 0.4 1.2 0.5 2.6 0.4 1.2 0.6 2.6 0.4 159 27 134 165 18.1 0.2 18.8 17.7 05/24/2006 10:30:00 1 0.7 3 0.4 1.1 0.8 3 0.4 1.2 0.8 3.4 0.4 160 33 128 165 18.5 0.1 18.8 18 05/24/2006 10:40:00 1.4 0.6 3 0.4 1.3 0.6 3 0.4 1.4 0.6 3.4 0.4 177 66 156 165 18.7 0.2 19.4 18.2 05/24/2006 10:50:00 1.9 0.5 3.4 1.1 1.8 0.5 3.8 1.1 2 0.5 3.8 0.4 160 11 164 165 17.9 0 18.2 17.7 05/24/2006 11:00:00 2.2 0.6 3.8 1.1 2.1 0.6 3.8 1.1 2.2 0.6 3.8 1.1 159 9 153 165 18 0 18.2 17.7 05/24/2006 11:10:00 2 0.3 3.4 1.5 2 0.3 3 1.5 2.1 0.4 3.4 1.1 157 7 158 165 18 0.2 18.2 17.4 05/24/2006 11:20:00 1.7 0.4 3 0.7 1.7 0.4 2.6 0.7 1.9 0.4 3 0.7 156 10 137 165 18 0.2 18.5 17.1 05/24/2006 11:30:00 1.8 0.6 3.8 0.4 1.7 0.7 3.4 0.4 2 0.6 3.4 0.4 161 18 164 165 18.5 0 18.8 18.2 05/24/2006 11:40:00 1.8 0.6 3 0.4 1.8 0.6 3 0.4 2 0.6 3.4 0.4 174 14 154 165 18.7 0 18.8 18.5 05/24/2006 11:50:00 2.1 0.6 3.8 0.7 2.1 0.6 3.8 0.7 2.2 0.7 3.8 0.7 179 19 165 165 18.3 0 18.8 18 05/24/2006 12:00:00 1.9 0.6 3.4 0.4 1.9 0.6 3.8 0.4 2.1 0.5 3.8 0.7 169 13 165 165 18.4 0.2 18.8 18 05/24/2006 12:10:00 1.7 0.7 3.4 0.4 1.7 0.7 3.8 0.4 1.9 0.6 3.8 0.7 163 17 165 165 18.4 0.1 18.8 18 05/24/2006 12:20:00 2.1 0.5 3.4 1.1 2.1 0.5 3 0.7 2.2 0.5 3.4 1.1 167 17 158 165 18.3 0.2 19.1 17.7 05/24/2006 12:30:00 1.2 0.5 2.6 0.4 1.2 0.6 2.6 0.4 1.5 0.5 3 0.4 174 22 139 165 18.5 0.1 19.1 18 05/24/2006 12:40:00 2.3 0.6 4.2 0.7 2.3 0.7 4.2 0.7 2.5 0.7 4.2 0.7 183 17 171 165 18.8 0.1 19.1 18.2 05/24/2006 12:50:00 2.4 0.3 3.4 1.5 2.3 0.3 3.4 1.1 2.5 0.4 3.8 1.5 164 9 162 165 18.2 0 18.5 18 05/24/2006 13:00:00 2.3 0.4 3.8 1.1 2.2 0.4 4.2 1.1 2.2 0.5 3.4 0.7 178 10 150 165 18.2 0.1 18.8 18 05/24/2006 13:10:00 2.1 0.4 3.4 1.1 2 0.4 3 1.1 2.1 0.5 3.4 1.1 177 12 170 165 18.4 0.2 19.1 17.7 05/24/2006 13:20:00 2 0.5 3 1.1 2 0.5 3 1.1 2.2 0.5 3.4 1.1 179 16 178 165 18.1 0.1 18.5 17.7 05/24/2006 13:30:00 2.1 0.5 3.4 0.7 2.1 0.5 3.4 0.4 2.1 0.5 3.8 1.1 183 15 193 165 18.5 0.1 18.8 18 05/24/2006 13:40:00 2.2 0.5 3.4 0.4 2.1 0.5 3.4 0.4 2.3 0.5 3.4 1.1 188 13 185 165 18.9 0 19.1 18.5 05/24/2006 13:50:00 2.4 0.5 4.2 1.1 2.4 0.5 4.2 1.1 2.5 0.6 4.6 0.7 186 13 167 165 19.3 0.1 19.7 18.8 05/24/2006 14:00:00 2.5 0.5 3.4 0.4 2.5 0.4 3.4 0.7 2.4 0.4 3.4 0.7 183 9 185 165 19.2 0.2 20 18.8 05/24/2006 14:10:00 2.5 0.4 3.4 1.1 2.5 0.4 3.4 1.1 2.4 0.4 3.4 1.1 183 9 180 165 19 0 19.7 18.5 05/24/2006 14:20:00 2.3 0.4 3.8 1.1 2.3 0.4 3.8 1.1 2.2 0.5 3.8 0.4 179 13 177 165 18.8 0 19.4 18.5 05/24/2006 14:30:00 2.2 0.4 3 1.1 2.1 0.4 3.4 1.1 2.2 0.4 3.4 1.5 172 12 157 165 18.7 0.3 19.4 18 05/24/2006 14:40:00 2.2 0.4 3.4 1.1 2.1 0.4 3.4 1.1 2.1 0.4 3.4 1.1 171 9 173 165 17.8 0 18.2 17.4 05/24/2006 14:50:00 1.9 0.4 3 0.4 1.8 0.4 3 0.4 1.8 0.3 3 0.7 169 9 164 165 17.9 0 18.2 17.7 05/24/2006 15:00:00 2 0.5 3.4 0.4 2 0.5 3 0.7 2.2 0.5 3.4 1.1 168 12 156 165 18.3 0 18.5 18 05/24/2006 15:10:00 1.9 0.6 3 0.4 2 0.6 3.4 0.4 2.2 0.6 3.4 0.7 162 17 181 165 18.4 0 18.5 18.2 05/24/2006 15:20:00 1.9 0.5 3 0.4 1.9 0.5 3 0.7 2 0.4 3 0.7 172 20 165 165 18.2 0 18.5 18 05/24/2006 15:30:00 2.1 0.6 3.4 0.4 2.1 0.5 3.4 0.7 1.9 0.6 3.4 0.4 181 19 164 165 19 0.3 19.4 18.5 05/24/2006 15:40:00 2.3 0.6 3.8 0.7 2.3 0.5 3.4 1.1 2.4 0.5 3.8 1.1 169 13 179 165 19.2 0 19.4 18.8 05/24/2006 15:50:00 2.2 0.6 3.8 0.7 2.2 0.5 3.8 1.1 2.4 0.5 3.8 0.7 172 13 153 165 19.5 0 19.7 19.4 05/24/2006 16:00:00 2.4 0.6 3.8 1.1 2.4 0.6 3.8 1.1 2.6 0.6 4.2 1.1 174 16 196 165 19.4 0 19.7 19.1 05/24/2006 16:10:00 2.8 0.5 4.2 1.5 2.8 0.4 4.2 1.5 2.8 0.5 4.2 1.1 179 9 180 165 19.2 0 19.7 18.8 05/24/2006 16:20:00 2.6 0.4 3.8 1.5 2.6 0.4 3.8 1.5 2.6 0.4 4.2 1.5 173 8 164 165 19.1 0 19.4 18.8 05/24/2006 16:30:00 2.7 0.4 3.8 1.9 2.7 0.3 3.4 1.5 2.7 0.3 3.4 1.9 170 7 190 165 19.2 0.1 19.7 18.8 05/24/2006 16:40:00 2.5 0.3 3.8 1.5 2.4 0.4 3.8 1.9 2.5 0.4 3.8 1.5 166 7 164 165 19.1 0 19.4 18.8 05/24/2006 16:50:00 2.4 0.3 3.4 1.5 2.4 0.3 3.4 1.5 2.4 0.3 3.4 1.9 142 7 135 165 18.7 0 19.1 18.2 05/24/2006 17:00:00 2.6 0.4 3.4 1.9 2.6 0.4 3.4 1.9 2.6 0.4 3.8 1.9 157 8 164 165 19 0 19.1 18.5 05/24/2006 17:10:00 2.6 0.5 4.2 1.5 2.6 0.5 4.2 1.5 2.7 0.4 3.8 1.5 152 10 165 165 19 0 19.4 18.8 05/24/2006 17:20:00 2.6 0.4 4.2 1.5 2.5 0.4 4.2 1.5 2.6 0.4 3.8 1.5 146 9 139 165 19.1 0 19.4 19.1 05/24/2006 17:30:00 2.5 0.3 3.8 1.9 2.5 0.3 3.4 1.5 2.5 0.3 3.4 1.9 145 9 147 165 19 0 19.1 18.8 05/24/2006 17:40:00 2.7 0.3 3.4 1.9 2.6 0.3 3.4 1.9 2.5 0.3 3.4 1.9 150 8 151 165 18.7 0 19.1 18.2 05/24/2006 17:50:00 2.4 0.3 3 1.9 2.4 0.2 3 1.9 2.4 0.2 3 1.9 145 6 142 165 17.8 0.2 18.5 17.4 05/24/2006 18:00:00 2.4 0.3 3 1.5 2.4 0.3 3 1.5 2.4 0.3 3 1.5 134 8 146 165 18.2 0.2 18.5 17.7 05/24/2006 18:10:00 2.2 0.3 3 1.5 2.2 0.3 3 1.5 2.2 0.3 3 1.1 128 6 125 165 18.3 0 18.5 18.2 05/24/2006 18:20:00 1.8 0.4 2.6 1.1 1.7 0.4 3 1.1 1.7 0.4 2.6 1.1 143 16 128 165 18 0 18.2 17.7 05/24/2006 18:30:00 1.7 0.2 2.3 1.1 1.6 0.2 1.9 1.1 1.4 0.3 1.9 0.4 177 5 180 165 17.9 0.2 18.8 17.4 05/24/2006 18:40:00 1.1 0.3 1.9 0.4 1 0.3 1.9 0.4 1 0.3 1.9 0.4 179 7 186 165 18.8 0.2 19.1 18.2 05/24/2006 18:50:00 0.8 0.3 1.9 0.4 0.8 0.3 1.9 0.4 0.8 0.3 1.5 0.4 173 7 169 165 19.2 0 19.7 19.1 05/24/2006 19:00:00 0.4 0.1 1.1 0.4 0.4 0.1 1.1 0.4 0.4 0.1 0.7 0.4 164 0 164 165 19.3 0 20 19.1 05/24/2006 19:10:00 0.4 0 0.7 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 66 49 42 165 19 0 19.1 18.8 05/24/2006 19:20:00 0.7 0.5 2.3 0.4 0.7 0.4 1.9 0.4 0.4 0.1 1.1 0.4 336 66 332 165 18.9 0 19.1 18.8 05/24/2006 19:30:00 0.5 0.3 1.5 0.4 0.5 0.3 1.5 0.4 0.4 0.1 1.1 0.4 253 17 300 165 18.8 0 19.1 18.5 05/24/2006 19:40:00 0.5 0.3 1.9 0.4 0.5 0.3 1.5 0.4 0.4 0.2 1.1 0.4 290 17 297 165 18.5 0 18.8 18.5 05/24/2006 19:50:00 0.7 0.3 1.5 0.4 0.6 0.3 1.5 0.4 0.5 0.3 1.9 0.4 297 5 302 165 18.5 0 18.5 18.2 05/24/2006 20:00:00 0.7 0.4 1.5 0.4 0.7 0.4 1.5 0.4 0.4 0.2 1.5 0.4 284 11 284 165 18.2 0 18.5 18 05/24/2006 20:10:00 1.6 0.2 2.3 1.1 1.6 0.2 2.3 1.1 1.2 0.3 1.9 0.4 293 6 291 165 17.8 0.1 18.2 17.4 05/24/2006 20:20:00 1.3 0.3 2.3 0.7 1.4 0.3 2.3 0.7 1 0.4 2.3 0.4 297 10 291 165 17.2 0 17.4 16.8 05/24/2006 20:30:00 2.3 0.6 3.4 1.1 2.3 0.6 3.4 1.1 1.6 0.5 3 0.4 299 8 307 165 16.8 0 17.1 16.8 05/24/2006 20:40:00 3 0.5 3.8 1.9 3 0.5 3.8 1.5 2.1 0.4 3 1.1 300 5 303 165 16.8 0 16.8 16.8 05/24/2006 20:50:00 3.8 0.3 4.6 2.6 3.8 0.3 4.6 2.6 2.7 0.4 3.8 1.5 305 3 307 165 16.8 0 16.8 16.8 05/24/2006 21:00:00 4.7 0.5 6.1 3.4 4.7 0.5 6.1 3.4 3.6 0.7 5.3 1.9 307 4 316 165 16.6 0 16.8 16.3 05/24/2006 21:10:00 5.7 0.5 6.8 4.6 5.7 0.5 6.8 4.6 4.4 0.5 5.7 3 306 5 302 165 16.4 0 16.6 16.3 05/24/2006 21:20:00 6.8 0.5 8.4 5.3 6.8 0.6 8 5.7 4.9 0.4 6.5 3.8 303 3 302 165 16.5 0 16.8 16.3 05/24/2006 21:30:00 7.4 0.6 9.1 6.1 7.4 0.6 9.1 6.1 5.4 0.7 7.6 4.2 303 4 307 165 16.6 0 16.8 16.6 05/24/2006 21:40:00 7.3 0.6 8.8 5.3 7.3 0.6 8.8 5.7 5.4 0.6 7.2 4.2 305 6 304 165 16.4 0 16.6 16.3 05/24/2006 21:50:00 7.5 0.5 8.8 6.5 7.6 0.5 8.8 6.1 5.4 0.6 7.2 4.2 302 4 300 165 16.3 0 16.6 16.3 05/24/2006 22:00:00 8.2 0.6 9.9 6.8 8.3 0.6 9.9 6.8 6.4 0.9 8.8 4.2 297 5 298 165 16.3 0 16.6 16.3 05/24/2006 22:10:00 9.1 0.5 10.3 7.6 9.2 0.5 10.7 7.6 6.9 0.7 9.1 5.3 295 5 300 165 16.1 0 16.6 16 05/24/2006 22:20:00 8.9 0.5 9.9 6.8 9 0.6 10.3 6.8 6.3 0.6 8.4 4.9 303 3 300 165 16.1 0 16.6 16 05/24/2006 22:30:00 7.8 0.5 8.8 6.1 7.8 0.5 9.1 6.5 5.6 0.6 8 4.2 301 4 304 165 15.9 0 16.3 15.7 05/24/2006 22:40:00 6.8 1.2 9.5 3.4 6.8 1.2 9.5 3.4 5.4 0.8 8 3.4 304 7 294 165 15.9 0 16.3 15.7 05/24/2006 22:50:00 4.9 0.6 6.5 3.4 5 0.7 6.5 3.8 4.3 0.5 5.7 3 307 8 305 165 15.7 0 16 15.7 05/24/2006 23:00:00 4.7 0.7 6.8 3 4.7 0.7 6.5 2.6 4.1 0.7 5.7 2.3 308 8 309 165 15.7 0 16 15.7 05/24/2006 23:10:00 5.4 0.7 7.6 3.8 5.5 0.7 7.6 3.8 4.8 0.6 6.5 3.4 308 9 303 165 15.5 0.2 15.7 15.2 05/24/2006 23:20:00 5.3 0.7 7.2 2.6 5.2 0.7 6.8 3 4.9 0.6 6.5 3.4 313 9 307 165 15.2 0 15.5 15.2 05/24/2006 23:30:00 7.9 0.8 9.5 5.7 7.9 0.8 9.9 5.7 6.1 0.7 7.6 4.2 303 5 302 165 15.4 0.1 15.7 15.2 05/24/2006 23:40:00 9.1 0.6 11.1 7.6 9.2 0.6 10.7 7.2 6.5 0.7 9.1 4.6 299 4 295 165 15.7 0 16 15.7 05/24/2006 23:50:00 8.8 0.5 9.9 6.8 9 0.5 10.3 7.2 6.6 0.8 8.8 4.9 298 4 298 165 15.8 0 16 15.7 05/25/2006 00:00:00 7.3 1.1 9.5 4.6 7.5 1.1 9.9 4.9 6.8 1.2 9.9 4.2 290 6 285 165 15.9 0 16.3 15.7 05/25/2006 00:10:00 5.3 0.8 7.6 3.4 5.4 0.8 8 3.4 5.7 0.9 8 3.4 287 8 286 165 15.7 0 16 15.7 05/25/2006 00:20:00 5.4 0.9 8.4 3.8 5.5 1 8.4 3.4 5.5 1 8.4 3 292 10 293 165 15.6 0 16 15.5 05/25/2006 00:30:00 7 0.8 9.1 5.3 7.1 0.8 9.5 5.3 6.1 0.9 9.5 3.8 302 7 295 165 15.6 0 15.7 15.5 05/25/2006 00:40:00 7 0.9 9.1 4.6 7.1 0.8 9.1 4.9 6.2 1 9.1 3.8 297 8 290 165 15.7 0.1 16.3 15.5 05/25/2006 00:50:00 6.6 1 9.1 4.9 6.7 1 8.8 4.9 6.1 1.1 9.1 3.8 298 8 295 165 16 0 16.3 16 05/25/2006 01:00:00 5.9 0.7 8.8 4.2 6 0.8 8.8 4.2 5.7 1 8.4 3.8 294 8 282 165 15.9 0 16.3 15.7 05/25/2006 01:10:00 6.7 1 9.5 4.6 6.8 1 9.5 4.6 6.4 1.1 9.1 3.8 291 6 289 165 15.9 0 16.3 15.7 05/25/2006 01:20:00 7.4 0.7 9.5 4.9 7.4 0.7 9.5 5.3 6.3 0.8 8.8 4.6 297 6 287 165 16.1 0.1 16.3 15.7 05/25/2006 01:30:00 8.3 0.6 10.3 6.5 8.4 0.6 10.3 6.8 6.6 0.9 9.1 4.6 296 5 290 165 16.2 0 16.3 16.3 05/25/2006 01:40:00 8.6 0.4 9.9 6.8 8.7 0.4 9.9 7.2 6.7 0.7 8.8 4.9 295 3 298 165 16.1 0 16.3 15.7 05/25/2006 01:50:00 8.9 0.4 9.9 7.6 9 0.4 9.9 8 6.7 0.8 8.8 4.9 296 4 297 165 15.9 0 16.3 15.7 05/25/2006 02:00:00 8.4 0.4 9.5 7.2 8.5 0.4 9.5 7.2 6.5 0.9 8.8 4.9 295 5 296 165 16.1 0 16.3 15.7 05/25/2006 02:10:00 8.2 0.5 9.5 7.2 8.4 0.5 9.5 7.2 7.2 0.7 8.8 5.3 292 4 289 165 15.9 0 16.3 15.5 05/25/2006 02:20:00 8.5 0.5 9.5 6.8 8.6 0.5 9.9 7.2 6.9 0.9 9.5 4.9 294 5 292 165 16 0 16.3 15.7 05/25/2006 02:30:00 8 0.7 9.9 6.1 8 0.7 9.9 6.1 6 0.7 8.8 4.2 300 5 297 165 16 0 16.3 15.7 05/25/2006 02:40:00 7.1 0.7 9.1 5.7 7.1 0.6 8.8 5.7 5.4 0.7 7.2 3.8 298 6 292 165 15.9 0 16.3 15.5 05/25/2006 02:50:00 6.8 0.7 8.8 4.9 6.8 0.7 8.4 4.9 5.4 0.7 7.6 3.8 297 5 298 165 15.7 0.1 16.3 15.7 05/25/2006 03:00:00 6.6 0.8 8.8 4.6 6.6 0.8 8.8 4.6 5.2 0.8 7.2 3 299 7 307 165 15.6 0 16 15.2 05/25/2006 03:10:00 7 0.8 9.5 4.9 7 0.8 9.5 5.3 5.3 0.9 8.4 3.4 299 6 290 165 15.6 0 15.7 15.2 05/25/2006 03:20:00 7.6 0.7 9.5 4.9 7.7 0.7 9.5 6.1 5.7 0.7 7.6 4.2 299 5 300 165 15.7 0.1 16.3 15.2 05/25/2006 03:30:00 7.4 0.9 9.1 4.9 7.5 0.9 9.1 5.3 5.6 0.8 8.8 3.8 300 5 304 165 15.7 0 16 15.5 05/25/2006 03:40:00 7.5 0.8 9.5 5.7 7.5 0.7 9.5 5.7 5.5 0.9 8.4 3.8 298 5 302 165 15.8 0.1 16 15.2 05/25/2006 03:50:00 7.8 0.7 9.9 6.1 7.8 0.7 9.9 6.1 6.8 1 9.9 3.8 291 4 290 165 15.6 0 15.7 15.2 05/25/2006 04:00:00 8.2 0.7 10.3 6.5 8.3 0.6 10.3 6.8 7.1 0.9 9.5 4.6 291 5 298 165 15.7 0 16 15.2 05/25/2006 04:10:00 7.5 0.8 9.5 5.3 7.6 0.8 9.9 5.3 6.6 1 9.5 3.8 291 5 287 165 16.1 0 16.3 15.5 05/25/2006 04:20:00 5.7 1.5 8.8 2.3 5.8 1.4 8.8 2.6 4.9 1.3 9.1 2.3 297 11 281 165 16.1 0.1 16.6 15.7 05/25/2006 04:30:00 3.6 0.8 5.7 1.1 3.7 0.8 5.7 1.1 3.3 0.8 5.7 1.5 302 12 298 165 16.3 0.1 16.6 15.7 05/25/2006 04:40:00 3.5 0.7 5.3 1.5 3.5 0.7 5.3 1.5 3.3 0.8 6.1 1.5 300 14 292 165 16.2 0.1 16.6 15.7 05/25/2006 04:50:00 4 0.8 6.5 2.3 4.1 0.8 6.5 2.3 3.8 1.1 7.6 1.9 294 10 290 165 16.1 0 16.6 15.7 05/25/2006 05:00:00 4.2 0.7 6.1 1.9 4.3 0.7 6.5 1.9 4.7 1 6.8 1.9 287 11 297 165 16.2 0.1 16.3 15.7 05/25/2006 05:10:00 3.6 0.8 5.3 1.5 3.6 0.8 5.7 1.9 3.8 0.8 6.1 2.3 287 11 281 165 16.6 0 16.8 16.3 05/25/2006 05:20:00 4.5 0.7 6.1 2.6 4.6 0.7 6.1 2.6 4.4 0.9 6.5 2.3 295 9 290 165 16.4 0 16.8 15.7 05/25/2006 05:30:00 5 0.7 6.8 3 5.1 0.8 7.2 3 4.6 0.8 7.2 2.3 294 8 286 165 16.5 0 16.8 16.3 05/25/2006 05:40:00 5.6 1.1 8.8 3 5.6 1.1 8.8 3.4 5.3 1.2 8.8 3 293 8 289 165 16.6 0 16.8 16.6 05/25/2006 05:50:00 7.2 1 10.3 4.6 7.3 1 9.9 4.9 6.4 1.1 9.1 3.4 293 8 307 165 16.4 0 16.8 16.3 05/25/2006 06:00:00 8 1.3 11.5 4.6 8.1 1.3 11.5 4.2 6.8 1.3 10.3 4.2 295 8 297 165 16.6 0 16.8 16.6 05/25/2006 06:10:00 9.4 0.8 11.8 7.6 9.5 0.9 11.8 7.6 8.1 1.2 11.5 4.9 291 5 282 165 16.7 0 16.8 16.6 05/25/2006 06:20:00 8.7 0.9 10.3 5.7 8.8 1 10.7 5.7 7.8 1.3 11.5 4.6 289 5 286 165 17 0 17.1 16.8 05/25/2006 06:30:00 8.9 0.8 10.7 6.8 9 0.8 10.7 6.5 8 1 9.9 4.9 289 4 278 165 17.1 0 17.4 17.1 05/25/2006 06:40:00 9.2 1.1 11.8 6.1 9.3 1.2 11.5 6.1 8.3 1.6 11.8 4.6 289 6 284 165 17.3 0 17.4 17.1 05/25/2006 06:50:00 8.7 1.1 11.8 6.1 8.8 1.2 11.1 5.7 8.3 1.5 12.2 4.6 287 6 282 165 17.5 0 17.7 17.4 05/25/2006 07:00:00 7.9 1.3 11.1 4.9 8 1.3 11.1 4.9 7.1 1.5 11.1 3.4 289 8 282 165 17.7 0 17.7 17.4 05/25/2006 07:10:00 7.4 0.9 9.5 4.9 7.5 0.9 9.1 4.9 6.3 1.1 8.8 3.4 291 7 290 165 17.8 0.1 18 17.4 05/25/2006 07:20:00 7.3 1.3 10.7 4.2 7.4 1.3 10.3 4.6 6.1 1.5 10.3 3.4 294 7 291 165 18 0 18.2 17.7 05/25/2006 07:30:00 7.3 1 10.3 4.2 7.3 1 10.3 4.2 6.5 1.2 9.5 3.4 289 7 294 165 18.2 0 18.5 18 05/25/2006 07:40:00 6.6 1.3 9.5 3.4 6.8 1.3 9.9 3.4 6.4 1.6 10.7 3 286 12 282 165 18.5 0 18.8 18.2 05/25/2006 07:50:00 7 1.5 10.3 3.4 7.1 1.5 10.3 3.8 6.1 1.6 9.9 2.6 291 12 295 165 18.7 0 18.8 18.5 05/25/2006 08:00:00 7.1 1.3 9.9 4.2 7.1 1.3 9.9 3.8 6.5 1.6 10.3 2.3 290 10 284 165 18.8 0 19.1 18.5 05/25/2006 08:10:00 7.1 1.1 9.5 4.2 7.1 1.1 9.5 4.2 6.4 1.3 9.1 3.8 289 10 282 165 19 0.1 19.1 18.5 05/25/2006 08:20:00 6.4 0.9 9.1 4.2 6.6 0.9 9.1 4.2 6.2 1.2 9.5 3.4 285 10 281 165 19.3 0 19.7 19.1 05/25/2006 08:30:00 5.5 1.2 8.8 2.3 5.7 1.2 9.1 2.3 5.1 1.6 8.8 1.9 291 15 291 165 19.7 0.1 20.2 19.4 05/25/2006 08:40:00 5 1 8 2.6 5.1 1 8 2.3 4.3 0.9 6.8 1.5 301 18 296 165 20.5 0.1 21.1 20.2 05/25/2006 08:50:00 6.8 1.5 10.7 2.6 6.9 1.5 11.1 2.6 6.5 1.7 11.1 3 287 13 283 165 20 0.3 21.1 19.4 05/25/2006 09:00:00 7.5 1.1 10.7 4.6 7.6 1.1 10.7 4.6 7.3 1.5 10.7 4.2 288 11 297 165 19.4 0 19.7 19.1 05/25/2006 09:10:00 6.4 1.5 9.5 2.6 6.5 1.5 9.5 2.6 5.9 1.5 9.1 2.3 293 13 289 165 19.5 0.1 20 19.1 05/25/2006 09:20:00 5.8 1.3 9.1 2.6 5.8 1.3 9.1 2.6 4.9 1.3 8.8 1.9 294 11 288 165 20.3 0.4 21.1 19.7 05/25/2006 09:30:00 4.3 1.1 6.8 1.9 4.5 1.1 7.2 1.9 4 1.2 6.8 0.7 283 17 277 165 21.1 0.2 21.7 20.8 05/25/2006 09:40:00 3.2 1.3 7.2 0.4 3.5 1.3 6.8 0.4 3 1.5 8.4 0.4 263 56 193 165 21.7 0.3 22.3 21.1 05/25/2006 09:50:00 3.7 1.3 6.8 0.4 4.2 1.3 6.8 0.4 3.8 1.5 6.8 0.4 261 24 284 165 21.3 0 21.7 20.8 05/25/2006 10:00:00 2.8 0.9 4.9 0.4 3.1 1 5.3 0.4 2.7 1 4.9 0.4 266 41 290 165 22.1 0 22.3 21.1 05/25/2006 10:10:00 3.6 0.9 5.7 1.5 4.1 1 7.2 1.9 3.7 1 5.7 1.5 268 17 256 165 22.2 0 22.6 22 05/25/2006 10:20:00 3.9 1 6.1 1.1 4.5 1 6.5 0.7 4.2 1 6.5 1.5 272 10 274 165 22.2 0 22.6 21.7 05/25/2006 10:30:00 4.5 1 6.5 1.5 4.8 0.8 6.8 1.9 4.5 1 7.2 1.9 278 11 282 165 22.7 0 22.9 22.3 05/25/2006 10:40:00 5.7 0.9 7.6 3 6.1 0.9 8 3.4 6.1 1 8.4 3.8 277 9 275 165 22 0.2 22.6 21.4 05/25/2006 10:50:00 6.8 0.8 8.8 4.2 7.1 0.8 9.1 4.9 7 0.9 9.1 4.2 280 8 273 165 21.4 0 21.7 20.5 05/25/2006 11:00:00 6.9 1.1 8.8 3.4 7.1 1 9.1 4.6 6.8 1.2 9.5 4.2 282 7 283 165 21.3 0.2 21.7 21.1 05/25/2006 11:10:00 6 0.9 8.4 3.8 6.6 0.8 8.8 4.2 6.5 1 8.8 3.8 276 9 289 165 21.9 0.2 22.3 21.4 05/25/2006 11:20:00 5.1 0.8 7.2 2.6 5.8 0.7 7.6 3.4 5.6 0.9 7.6 3 275 8 271 165 22.4 0 22.9 21.7 05/25/2006 11:30:00 6.4 1.1 8.8 3.4 7 0.9 8.8 4.2 6.9 1 8.4 4.6 273 6 282 165 22.3 0.4 22.9 21.1 05/25/2006 11:40:00 6.6 0.6 8.4 4.2 6.8 0.6 8.4 4.6 6.7 0.6 8.4 4.6 277 4 274 165 21.6 0.1 22 21.4 05/25/2006 11:50:00 6.5 0.6 8 4.6 6.6 0.6 7.6 4.6 6.2 0.8 8 3.8 288 8 287 165 21.8 0 22 21.7 05/25/2006 12:00:00 5.8 0.8 7.6 3 5.9 0.8 8 3 4.9 0.9 7.2 2.6 298 10 303 165 22.3 0.4 23.2 21.7 05/25/2006 12:10:00 5.8 0.5 7.2 4.6 5.8 0.5 7.2 4.2 4.6 0.6 6.8 2.6 299 6 297 165 22.7 0.1 23.2 22.3 05/25/2006 12:20:00 5 0.7 6.5 3.4 5.1 0.6 6.5 3.4 4.3 0.6 6.1 2.3 296 8 287 165 22.8 0.2 23.5 22.6 05/25/2006 12:30:00 4.1 0.7 6.1 1.9 4.2 0.6 6.1 2.6 3.6 0.7 5.7 2.3 287 10 285 165 23.7 0.2 24.4 23.2 05/25/2006 12:40:00 4.5 0.7 6.5 3 4.5 0.6 6.5 3 3.9 0.7 5.7 1.9 295 8 290 165 23.6 0 24.7 23.5 05/25/2006 12:50:00 4.8 0.6 6.8 3 4.8 0.6 6.5 3 4.1 0.6 6.1 2.6 302 10 304 165 23.5 0 23.8 23.2 05/25/2006 13:00:00 4.4 0.7 6.5 2.6 4.4 0.7 6.1 2.6 3.5 0.8 6.1 1.5 304 12 289 165 24.5 0.4 25.3 23.5 05/25/2006 13:10:00 5.5 0.9 7.6 3 5.5 0.9 8 3.4 4.5 1 8 1.9 301 9 307 165 24.8 0.1 25.3 24.1 05/25/2006 13:20:00 6.2 0.6 7.6 4.2 6.2 0.6 7.6 4.2 5.2 0.7 7.2 3.4 305 6 308 165 23.5 0.2 24.7 23.2 05/25/2006 13:30:00 6.5 0.7 8 4.6 6.5 0.7 8 4.6 5.4 0.7 7.2 3.4 305 8 300 165 23.3 0 23.5 22.9 05/25/2006 13:40:00 7.2 0.8 9.1 4.6 7.2 0.7 8.8 4.9 5.8 0.7 8 3.8 305 6 314 165 23.1 0.2 23.5 22.9 05/25/2006 13:50:00 7 0.7 8.8 4.6 7.1 0.7 9.1 4.6 5.8 0.7 8.4 4.2 305 6 302 165 22.7 0 23.5 22.3 05/25/2006 14:00:00 7 0.6 8.4 4.6 7 0.6 8.4 4.9 5.7 0.8 8 3.8 304 7 305 165 23 0.1 23.5 22.6 05/25/2006 14:10:00 7 0.6 8.4 5.3 7 0.5 8.4 5.3 5.5 0.8 8.4 3.8 304 5 308 165 23 0 23.5 22.9 05/25/2006 14:20:00 6.9 0.6 8.8 4.9 6.9 0.6 8.4 4.9 5.6 0.7 7.2 4.2 305 5 301 165 22.9 0 23.2 22.6 05/25/2006 14:30:00 6.7 0.6 8 4.6 6.7 0.6 8 4.9 5.6 0.7 7.2 3.8 307 5 313 165 23 0 23.2 22.9 05/25/2006 14:40:00 5.8 0.7 7.6 3.8 5.8 0.7 7.6 3.8 5.1 0.8 7.2 3 308 9 291 165 23.2 0.3 24.1 22.9 05/25/2006 14:50:00 6.1 0.7 7.6 4.2 6.1 0.7 7.6 4.2 5 0.7 7.2 3.4 302 6 300 165 23.3 0.2 24.4 22.9 05/25/2006 15:00:00 6.1 0.6 7.2 4.2 6.2 0.5 7.2 4.6 5.2 0.7 6.8 3.4 304 7 304 165 23 0 23.5 22.6 05/25/2006 15:10:00 6.2 0.7 8.8 4.6 6.2 0.7 8.8 4.2 5.5 0.9 8 3.8 309 7 307 165 23.3 0.2 23.8 22.9 05/25/2006 15:20:00 6.3 0.6 8 4.9 6.3 0.6 8 4.9 5.3 0.8 7.2 3.4 307 6 297 165 23 0 23.5 22.9 05/25/2006 15:30:00 6.2 0.6 7.6 4.2 6.2 0.6 7.6 4.2 5.6 0.7 7.6 3.8 309 6 310 165 23.1 0 23.8 22.9 05/25/2006 15:40:00 6.4 0.6 8 4.9 6.4 0.6 8 4.9 5.6 0.9 7.2 3.8 306 8 316 165 23.3 0.3 24.1 22.6 05/25/2006 15:50:00 6.2 0.6 8 4.6 6.2 0.6 8 4.6 5.3 0.7 8 3.8 304 8 304 165 23 0 23.2 22.6 05/25/2006 16:00:00 6.1 0.6 7.2 4.6 6.1 0.6 7.2 4.6 5.7 0.7 7.6 3.8 314 7 303 165 23.2 0 23.5 22.9 05/25/2006 16:10:00 6 0.6 8 4.6 6 0.6 7.6 4.2 5.8 0.8 7.6 3.4 315 8 327 165 23.2 0 23.5 22.6 05/25/2006 16:20:00 5.5 0.7 7.2 3.8 5.6 0.6 7.2 3.8 5.1 0.8 7.2 3.4 315 9 310 165 23.8 0.3 24.4 22.9 05/25/2006 16:30:00 6.2 0.6 8 4.6 6.1 0.6 7.6 4.6 5.7 0.7 7.6 3.8 315 7 310 165 23.7 0.1 24.1 22.9 05/25/2006 16:40:00 6.8 0.6 8 4.9 6.8 0.6 8 4.9 6 0.9 8 4.2 310 6 318 165 23 0.2 23.5 22.9 05/25/2006 16:50:00 6.7 0.6 8.4 4.9 6.7 0.6 8.4 4.9 6.3 0.8 8 4.2 311 5 300 165 22.8 0 23.2 22.6 05/25/2006 17:00:00 6.5 0.6 8 4.6 6.4 0.6 8 4.2 5.9 0.9 8 3.4 311 6 309 165 22.9 0 23.2 22.6 05/25/2006 17:10:00 5.8 0.8 7.6 3.8 5.8 0.8 7.6 3.8 5.5 0.8 7.2 3.4 312 8 309 165 22.8 0 23.2 22.6 05/25/2006 17:20:00 5.7 0.6 7.6 4.6 5.7 0.6 8 4.6 5.1 0.7 7.2 3.4 311 8 321 165 23 0.1 23.5 22.3 05/25/2006 17:30:00 5.7 0.7 7.2 3.8 5.6 0.7 7.2 3.8 5.2 0.9 6.5 2.6 310 8 306 165 22.7 0 23.2 22.3 05/25/2006 17:40:00 6.2 0.5 7.6 4.6 6.2 0.5 7.2 4.6 5.5 0.7 7.6 3.8 309 6 302 165 22.9 0.1 23.2 22.6 05/25/2006 17:50:00 5.7 0.6 6.8 3.8 5.7 0.6 7.2 3.8 5.1 0.8 6.8 3 307 8 304 165 22.7 0 22.9 22.3 05/25/2006 18:00:00 5.1 0.6 7.2 3.4 5.1 0.6 7.2 3.4 4.3 0.8 6.5 1.9 304 8 308 165 22.5 0 22.9 22.3 05/25/2006 18:10:00 5 0.6 6.5 3.8 5 0.6 6.5 3.4 4 0.6 5.7 2.6 299 5 299 165 22.3 0 22.6 22 05/25/2006 18:20:00 6 0.5 7.2 4.2 6 0.6 7.2 4.6 4.8 0.6 6.1 3 304 6 301 165 21.9 0.1 22.3 21.7 05/25/2006 18:30:00 6.6 0.5 8 5.3 6.6 0.5 8 5.3 5.1 0.6 7.2 3.8 304 5 307 165 21.8 0.1 22.3 21.4 05/25/2006 18:40:00 7.1 0.6 8.4 4.9 7.1 0.6 8.4 4.9 6 0.7 7.6 4.2 306 5 305 165 21.5 0 22 21.1 05/25/2006 18:50:00 6.8 0.6 8 4.6 6.8 0.6 8.4 4.9 5.2 0.6 6.8 3.8 303 5 291 165 21.1 0 21.4 20.8 05/25/2006 19:00:00 6 0.5 7.2 4.2 6 0.5 7.2 4.2 4.7 0.7 6.5 3 303 5 304 165 20.8 0.1 21.1 20.8 05/25/2006 19:10:00 6 0.5 7.2 4.6 6 0.5 7.2 4.2 4.4 0.5 6.1 3.4 299 5 297 165 20.6 0 20.8 20.5 05/25/2006 19:20:00 6 0.5 7.2 4.6 6 0.5 7.2 4.2 4.6 0.5 6.5 3.4 302 4 296 165 20.3 0 20.5 20.2 05/25/2006 19:30:00 6.1 0.4 6.8 4.6 6.1 0.5 7.2 4.6 4.6 0.5 6.1 3.4 302 4 298 165 20.1 0 20.5 20 05/25/2006 19:40:00 5.7 0.6 6.8 3.8 5.7 0.6 7.2 3.8 4.4 0.6 6.1 3 303 4 296 165 20 0 20.2 20 05/25/2006 19:50:00 5.5 0.5 6.5 3.8 5.5 0.5 6.5 3.4 4.3 0.6 6.1 3 299 6 306 165 20 0 20.2 20 05/25/2006 20:00:00 6.1 0.7 7.2 4.2 6.1 0.7 7.2 4.2 4.9 0.6 6.8 2.6 305 5 304 165 19.7 0.1 20 19.4 05/25/2006 20:10:00 6.2 0.4 7.2 4.6 6.2 0.4 7.2 4.9 4.6 0.5 6.1 3.8 304 3 302 165 19.5 0 19.7 19.4 05/25/2006 20:20:00 6 0.3 6.8 4.9 6 0.3 6.8 4.9 4.3 0.4 5.7 3 302 2 304 165 19.2 0 19.4 19.1 05/25/2006 20:30:00 6 0.4 6.8 4.6 6 0.4 6.8 4.9 4.9 0.5 6.1 3.8 305 4 301 165 19 0 19.1 18.5 05/25/2006 20:40:00 6.7 0.5 8 5.3 6.8 0.5 8 5.7 5.4 1.1 8.4 3.4 296 5 284 165 18.6 0 18.8 18.5 05/25/2006 20:50:00 7.1 0.6 8.8 4.9 7.2 0.6 8.8 5.3 6.2 1 8.4 3.8 293 4 285 165 18.5 0.1 18.8 18.2 05/25/2006 21:00:00 6.8 0.4 7.6 5.7 6.9 0.4 8 5.7 5.5 0.6 7.2 3.8 292 3 288 165 18 0.1 18.8 17.7 05/25/2006 21:10:00 6.9 0.4 8 6.1 7 0.4 8 6.1 5.9 0.7 7.2 3.8 293 3 296 165 17.4 0.1 17.7 17.4 05/25/2006 21:20:00 7.6 0.5 9.1 6.1 7.6 0.5 9.1 6.5 5.8 0.7 7.6 4.6 295 4 301 165 17.3 0 17.4 17.1 05/25/2006 21:30:00 7.8 0.8 9.9 5.7 7.8 0.8 9.9 5.3 5.7 0.9 8.4 3.8 304 4 304 165 17.3 0 17.4 17.1 05/25/2006 21:40:00 5.2 1.5 8.4 2.6 5.2 1.5 8.4 2.6 4.6 1 6.8 2.6 315 10 302 165 17.1 0 17.4 16.8 05/25/2006 21:50:00 2.1 1 4.2 0.4 2.1 1 4.2 0.4 2 0.9 4.2 0.4 315 27 313 165 17.4 0 17.7 17.4 05/25/2006 22:00:00 3.9 0.8 5.7 1.5 4 0.8 6.1 1.5 3.3 0.6 5.3 1.9 301 12 290 165 17.6 0.1 18 17.4 05/25/2006 22:10:00 5.6 0.6 8 3.8 5.6 0.6 7.6 3.8 4.1 0.6 6.1 2.3 297 8 301 165 17.3 0.2 17.7 16.8 05/25/2006 22:20:00 4.9 0.7 6.8 2.6 4.9 0.7 6.5 2.6 3.5 0.9 5.7 1.5 294 9 292 165 16.8 0 17.1 16.6 05/25/2006 22:30:00 4.6 0.9 6.5 1.5 4.7 0.8 6.1 1.9 4.1 1 6.1 1.1 281 12 289 165 16.8 0 16.8 16.6 05/25/2006 22:40:00 5.6 0.7 6.8 3.4 5.7 0.6 6.8 3.4 5 0.9 6.8 2.6 287 6 287 165 16.8 0 16.8 16.6 05/25/2006 22:50:00 6.3 0.6 7.6 4.6 6.4 0.6 7.6 4.6 5.5 0.8 7.2 3.4 292 6 293 165 16.9 0 17.1 16.8 05/25/2006 23:00:00 6.9 0.7 8.4 4.6 6.9 0.7 8.4 4.9 5.3 0.7 6.8 3 295 4 299 165 17.1 0 17.1 17.1 05/25/2006 23:10:00 7.4 0.6 8.8 6.1 7.5 0.6 8.8 6.1 6.1 0.9 8.4 3.8 295 4 294 165 17.1 0 17.4 16.8 05/25/2006 23:20:00 7.1 0.6 10.7 4.9 7.2 0.6 10.3 5.3 6.3 0.9 9.1 4.2 293 8 303 165 17 0 17.4 16.8 05/25/2006 23:30:00 7 0.7 9.5 5.3 7 0.7 9.5 5.3 5.6 0.8 7.6 3.4 301 9 291 165 17.3 0 17.4 17.1 05/25/2006 23:40:00 7.1 1 9.9 5.3 7.1 1 9.9 5.3 5.5 1 8.4 3.8 300 7 305 165 17.3 0 17.4 17.1 05/25/2006 23:50:00 6.9 0.7 9.5 5.3 6.9 0.7 9.1 5.3 5.3 0.7 7.6 3.8 299 7 304 165 17.3 0 17.4 17.1 05/26/2006 00:00:00 5.1 1.3 8 2.6 5.1 1.3 8 2.6 4.2 0.9 6.8 1.9 304 11 312 165 17.3 0.1 17.7 16.8 05/26/2006 00:10:00 2.8 0.8 4.9 1.1 2.9 0.8 4.9 1.5 2.6 0.8 5.3 0.7 303 18 311 165 17.5 0 17.7 17.4 05/26/2006 00:20:00 2.7 1 5.7 0.4 2.8 1 5.3 0.4 2.7 0.9 5.3 0.4 316 35 334 165 17.8 0 18 17.7 05/26/2006 00:30:00 0.8 0.5 2.3 0.4 0.9 0.6 2.6 0.4 1 0.6 3.4 0.4 267 29 219 165 17.5 0 18 17.4 05/26/2006 00:40:00 1.7 1.2 4.9 0.4 1.8 1.3 4.6 0.4 2 1 4.6 0.4 270 17 291 165 17.5 0 18 17.1 05/26/2006 00:50:00 3.6 0.8 5.7 1.1 3.6 0.8 5.3 0.7 3.1 0.8 4.9 1.1 304 13 292 165 17 0 17.4 16.8 05/26/2006 01:00:00 4 0.8 6.8 2.6 4 0.9 6.8 2.6 3.5 0.7 5.7 1.9 313 11 313 165 16.8 0 17.1 16.6 05/26/2006 01:10:00 4 0.6 5.3 2.6 4 0.6 5.3 2.6 3.5 0.6 4.9 1.9 313 10 309 165 16.8 0 17.1 16.6 05/26/2006 01:20:00 4.5 0.8 6.1 1.9 4.4 0.9 6.1 1.5 3.4 0.6 4.9 1.5 310 13 302 165 16.7 0.1 17.1 16.3 05/26/2006 01:30:00 5 0.8 7.6 3 5 0.8 7.6 2.6 3.4 0.9 5.3 1.1 296 9 306 165 16.5 0 16.8 16 05/26/2006 01:40:00 5.2 0.8 7.2 3 5.3 0.8 6.8 3 3.9 1 6.5 1.5 291 9 293 165 16.6 0 16.8 16.6 05/26/2006 01:50:00 5.4 0.9 8 2.6 5.4 0.9 8 3 3.8 1 6.8 1.9 297 9 304 165 16.6 0 16.8 16.6 05/26/2006 02:00:00 5.4 1.1 8.4 2.6 5.4 1 8.8 2.6 3.8 1.1 6.8 1.5 297 9 297 165 16.8 0 16.8 16.6 05/26/2006 02:10:00 5 1.2 8.4 2.3 5 1.1 8.4 2.3 3.4 1 6.5 0.4 294 10 307 165 16.6 0 16.8 16.6 05/26/2006 02:20:00 4.5 2.1 7.6 0.4 4.5 2.1 7.6 0.4 3.1 1.5 6.5 0.4 293 51 297 165 16.7 0 16.8 16.6 05/26/2006 02:30:00 2.7 1.1 5.7 0.4 2.7 1.1 4.9 0.4 2.1 1 4.9 0.4 300 29 298 165 16.8 0 17.4 16.8 05/26/2006 02:40:00 3.5 0.6 5.7 1.9 3.5 0.6 5.3 1.9 3.2 0.6 4.9 1.5 316 15 341 165 17 0.2 17.4 16.8 05/26/2006 02:50:00 4.1 0.7 6.1 1.9 4.1 0.7 6.1 1.9 3.5 0.6 5.3 1.1 309 9 293 165 17.1 0.2 17.7 16.8 05/26/2006 03:00:00 5.4 0.8 8 3.4 5.4 0.8 8 3.4 4.6 0.8 6.8 2.6 306 8 287 165 16.9 0 17.1 16.6 05/26/2006 03:10:00 5.3 0.7 7.2 3.4 5.3 0.7 7.2 3.4 4.6 0.7 6.5 2.6 308 8 306 165 16.9 0 17.1 16.3 05/26/2006 03:20:00 5.6 0.8 7.6 3.4 5.5 0.8 7.6 3 4.5 0.9 7.2 2.3 309 8 297 165 16.4 0.1 17.1 16.3 05/26/2006 03:30:00 5.7 0.8 8 3.8 5.6 0.8 7.6 3.8 4.7 0.8 6.8 2.6 309 7 313 165 16.6 0.2 16.8 16.3 05/26/2006 03:40:00 4.3 1.2 7.2 1.9 4.3 1.2 6.8 1.9 3.8 1 6.8 1.9 299 13 314 165 16.9 0 17.1 16.8 05/26/2006 03:50:00 3.4 0.8 4.9 0.7 3.4 0.9 4.9 0.4 3.2 0.6 5.3 1.5 298 12 290 165 17.1 0 17.4 16.8 05/26/2006 04:00:00 3.8 0.6 5.3 2.3 3.8 0.6 5.3 2.3 3.3 0.6 4.9 1.1 313 14 302 165 17.2 0.1 17.4 16.8 05/26/2006 04:10:00 3 0.7 4.6 1.5 3 0.7 4.9 1.5 2.8 0.6 4.9 1.5 307 21 316 165 17.3 0.1 17.4 17.1 05/26/2006 04:20:00 2.2 0.8 3.8 0.4 2.2 0.8 3.8 0.4 2.3 0.6 4.2 0.7 315 18 283 165 17.5 0 17.7 17.4 05/26/2006 04:30:00 2 0.6 3.8 0.7 1.8 0.7 4.2 0.4 2 0.7 3.8 0.4 321 26 289 165 17.3 0.1 17.7 16.8 05/26/2006 04:40:00 2.6 0.7 4.2 0.4 2.2 0.7 3.8 0.4 2.3 0.6 3.8 1.1 340 20 350 165 17.3 0.1 17.7 17.1 05/26/2006 04:50:00 2.7 0.7 4.2 0.7 2.3 0.9 4.2 0.4 2.6 0.7 4.6 1.1 353 15 348 165 17.5 0.1 17.7 17.4 05/26/2006 05:00:00 3.1 0.6 4.9 1.9 2.4 0.7 4.2 0.7 2.9 0.6 4.6 1.1 355 11 355 165 17.8 0 18 17.4 05/26/2006 05:10:00 2.7 0.7 4.6 1.1 2.3 0.7 4.6 0.7 2.5 0.6 4.2 1.1 346 11 335 165 18.1 0 18.2 17.7 05/26/2006 05:20:00 2.7 0.6 4.2 1.1 2.4 0.6 3.8 1.1 2.4 0.6 4.2 0.7 336 15 353 165 18.2 0 18.5 17.7 05/26/2006 05:30:00 2.6 0.5 3.8 1.5 2.1 0.5 3.4 0.7 2.3 0.5 3.4 1.1 342 15 325 165 18.3 0 18.5 18.2 05/26/2006 05:40:00 2.8 0.6 4.2 1.5 2.1 0.7 4.2 0.7 2.5 0.6 4.2 0.7 357 21 25 165 18.6 0.2 19.1 18.2 05/26/2006 05:50:00 2.4 0.9 4.2 0.7 2 1 4.2 0.4 2.5 0.9 4.6 0.4 19 16 39 165 19.7 0.4 20.5 19.1 05/26/2006 06:00:00 1.8 0.8 3.4 0.4 1.5 0.9 3.4 0.4 1.9 0.9 3.8 0.4 25 35 54 165 20.4 0 20.8 20.2 05/26/2006 06:10:00 1.6 0.6 2.6 0.4 1.4 0.6 2.6 0.4 1.6 0.5 3 0.4 338 35 18 165 20.2 0.2 20.8 20 05/26/2006 06:20:00 1.3 0.7 2.6 0.4 0.9 0.6 2.3 0.4 1.1 0.5 2.3 0.4 335 28 14 165 20.2 0.1 20.5 20 05/26/2006 06:30:00 1.9 0.9 4.2 0.4 1.8 1.1 4.2 0.4 1.7 0.8 3.4 0.4 304 29 302 165 20.4 0 20.8 20.2 05/26/2006 06:40:00 2.6 0.4 3.8 1.5 2.5 0.4 3.8 1.5 2 0.4 3 0.7 296 10 300 165 20 0 20.5 20 05/26/2006 06:50:00 2.7 0.7 4.6 1.1 2.5 0.7 4.6 0.7 2.4 0.7 4.2 1.1 328 17 336 165 20.6 0.3 21.1 20.2 05/26/2006 07:00:00 2.7 0.8 4.6 1.1 2.7 0.8 4.9 0.7 2.2 0.8 4.9 0.4 297 14 290 165 21.1 0 21.1 20.8 05/26/2006 07:10:00 3.5 0.7 4.9 1.5 3.6 0.7 4.9 1.5 3.1 0.6 4.6 1.5 291 7 289 165 20.2 0.1 20.8 20 05/26/2006 07:20:00 3.3 0.5 4.6 1.9 3.3 0.5 4.2 1.5 2.7 0.5 4.2 1.1 304 11 329 165 20.2 0 20.5 20 05/26/2006 07:30:00 2.8 0.6 4.2 1.5 2.5 0.7 4.2 1.1 2.6 0.7 4.6 0.7 326 28 279 165 21 0.5 22 20.2 05/26/2006 07:40:00 2.4 0.9 4.2 0.4 2.3 0.9 4.2 0.4 2.3 0.8 4.6 0.4 340 19 330 165 22.4 0.3 23.2 21.7 05/26/2006 07:50:00 1.9 0.6 3 0.4 2 0.5 3 0.4 1.7 0.6 3 0.4 328 9 325 165 23.4 0.2 24.1 22.9 05/26/2006 08:00:00 0.8 0.5 1.9 0.4 0.7 0.5 2.3 0.4 0.7 0.5 2.3 0.4 316 33 344 165 24.1 0.3 24.7 23.5 05/26/2006 08:10:00 0.9 0.5 2.6 0.4 0.8 0.5 2.6 0.4 0.7 0.4 2.3 0.4 310 43 9 165 24.4 0.1 24.7 24.1 05/26/2006 08:20:00 0.8 0.5 2.6 0.4 0.7 0.5 2.6 0.4 0.7 0.5 2.3 0.4 316 47 201 165 24.2 0.2 24.7 23.8 05/26/2006 08:30:00 1.6 0.5 3 0.4 1.6 0.5 3 0.4 1.4 0.6 2.6 0.4 289 38 332 165 23.5 0.4 24.4 22.9 05/26/2006 08:40:00 1.4 0.6 2.6 0.4 1.4 0.7 2.6 0.4 1.2 0.7 2.6 0.4 301 24 288 165 23.5 0.2 24.1 22.9 05/26/2006 08:50:00 0.9 0.5 3 0.4 0.9 0.6 3 0.4 0.8 0.5 2.3 0.4 295 43 280 165 24.1 0.1 24.7 23.5 05/26/2006 09:00:00 1.7 0.8 4.2 0.4 1.7 0.8 4.6 0.4 1.7 0.8 4.2 0.4 189 61 167 165 23.8 0.1 24.1 23.5 05/26/2006 09:10:00 2.1 0.5 3 0.7 2 0.6 3 0.4 2.3 0.5 3.4 0.7 138 17 144 165 23.2 0.2 23.8 22.9 05/26/2006 09:20:00 2.1 0.7 4.2 0.7 2.1 0.8 4.2 0.4 2.2 0.7 3.8 0.4 131 22 116 165 23.1 0 23.5 22.9 05/26/2006 09:30:00 2.1 0.6 3.8 0.7 2.1 0.6 3.8 0.7 2.2 0.6 4.2 1.1 139 19 162 165 23.4 0.1 24.1 22.9 05/26/2006 09:40:00 2.1 0.8 3.8 0.4 2.2 0.8 3.8 0.4 2.2 0.8 3.8 0.4 145 38 137 165 23.7 0 24.4 23.5 05/26/2006 09:50:00 1.5 0.8 3.4 0.4 1.4 0.8 3.8 0.4 1.3 0.8 3.8 0.4 47 66 109 165 24.3 0.6 25.3 23.5 05/26/2006 10:00:00 2.4 0.8 4.2 0.4 2.4 0.8 4.2 0.4 2.4 0.6 3.8 0.7 115 19 124 165 24.7 0.3 25.3 24.1 05/26/2006 10:10:00 1.4 0.8 3.8 0.4 1.4 0.8 3.8 0.4 1.3 0.8 3.4 0.4 173 94 122 165 24.2 0.4 25.3 23.8 05/26/2006 10:20:00 2.3 0.7 4.6 0.7 2.2 0.8 4.6 0.4 2 0.7 3.8 0.4 296 79 235 165 25.5 0.4 26.2 24.7 05/26/2006 10:30:00 1.5 1 4.6 0.4 1.5 1 4.9 0.4 1.3 0.8 4.2 0.4 145 61 219 165 24.2 0 24.7 23.8 05/26/2006 10:40:00 1.3 0.7 3.4 0.4 1.3 0.7 3.4 0.4 1.5 0.6 3.4 0.4 136 32 126 165 24.5 0.1 25 23.8 05/26/2006 10:50:00 1.6 1.1 4.2 0.4 1.5 1.1 4.2 0.4 1.4 0.9 3.4 0.4 10 86 355 165 25 0.4 25.9 24.1 05/26/2006 11:00:00 3.4 1.7 9.1 0.4 3.2 1.7 9.5 0.4 3.1 1.9 10.3 0.4 305 94 243 165 25.2 0.5 26.2 24.7 05/26/2006 11:10:00 2 1.2 5.3 0.4 2 1.2 4.6 0.4 1.7 1 4.2 0.4 340 107 317 165 25.6 0.3 26.2 24.7 05/26/2006 11:20:00 1.8 0.9 3.8 0.4 1.9 0.9 3.8 0.4 1.8 0.9 4.2 0.4 106 36 111 165 26.2 0.4 26.8 25 05/26/2006 11:30:00 2.4 0.8 4.6 0.4 2.4 0.8 4.2 0.4 2.3 0.8 4.6 0.4 140 27 152 165 25 0.3 25.6 23.8 05/26/2006 11:40:00 2.5 0.7 4.9 1.1 2.6 0.7 4.9 1.1 2.7 0.6 4.6 1.5 139 16 130 165 23.7 0.2 24.4 23.2 05/26/2006 11:50:00 3.7 0.8 5.7 1.9 3.8 0.9 6.1 1.9 3.8 0.8 5.7 1.9 131 12 156 165 23.9 0.2 24.4 23.5 05/26/2006 12:00:00 3.5 0.6 5.3 1.5 3.5 0.7 5.3 1.1 3.4 0.6 4.9 1.1 136 13 154 165 24 0.1 24.4 23.5 05/26/2006 12:10:00 3 0.6 4.6 1.5 3.1 0.6 4.6 1.5 3.1 0.5 4.6 1.5 140 13 133 165 24.1 0 24.4 23.8 05/26/2006 12:20:00 2.6 0.5 4.2 1.5 2.7 0.5 4.2 1.9 2.7 0.5 4.9 1.1 138 9 140 165 23.6 0.1 24.1 23.2 05/26/2006 12:30:00 3.2 0.6 4.6 1.5 3.3 0.6 4.6 1.5 3.3 0.6 5.7 1.9 141 16 151 165 23.9 0.2 24.4 23.5 05/26/2006 12:40:00 2.3 0.8 4.6 0.4 2.4 0.7 4.2 0.4 2.3 0.7 3.8 0.4 133 19 159 165 24.1 0 24.7 23.8 05/26/2006 12:50:00 2.4 0.7 4.6 0.7 2.5 0.7 4.6 0.7 2.5 0.7 4.6 0.7 156 12 142 165 24.7 0.1 25.3 24.4 05/26/2006 13:00:00 1.8 0.6 3 0.4 1.9 0.6 3.8 0.4 2 0.7 3.8 0.4 147 18 129 165 24.5 0.1 25 24.1 05/26/2006 13:10:00 1.6 0.7 3.8 0.4 1.7 0.6 3.4 0.4 1.9 0.6 3.8 0.4 158 16 158 165 24.3 0.2 24.7 24.1 05/26/2006 13:20:00 1.7 0.6 3.4 0.4 1.8 0.5 3.8 0.4 1.9 0.6 3.8 0.4 151 15 164 165 24.1 0.1 24.4 23.8 05/26/2006 13:30:00 1.7 1 4.2 0.4 1.8 0.9 4.2 0.4 1.6 0.9 4.2 0.4 164 22 160 165 24.6 0.4 25.3 23.8 05/26/2006 13:40:00 1.1 0.6 3.4 0.4 1.1 0.6 2.6 0.4 1.2 0.7 3.4 0.4 176 47 328 165 24.8 0 25.3 24.4 05/26/2006 13:50:00 1.1 0.6 3.4 0.4 1.1 0.6 3 0.4 0.9 0.6 2.6 0.4 185 56 334 165 24.8 0 25.3 24.4 05/26/2006 14:00:00 1.9 1.1 5.3 0.4 2 1.3 5.3 0.4 1.4 1 4.2 0.4 218 61 328 165 25 0.2 25.3 24.4 05/26/2006 14:10:00 2.1 1.4 6.8 0.4 2.2 1.5 6.5 0.4 1.4 1.1 6.1 0.4 280 79 273 165 25.1 0 25.6 24.7 05/26/2006 14:20:00 2.5 1.3 5.3 0.4 2.6 1.4 6.1 0.4 1.5 1 4.9 0.4 286 72 294 165 25 0.1 25.3 24.4 05/26/2006 14:30:00 3.5 1.3 6.5 0.4 3.5 1.3 6.5 0.4 2.5 1.2 6.1 0.4 284 45 322 165 25.3 0.2 25.6 25 05/26/2006 14:40:00 2.3 1.3 5.7 0.4 2.4 1.4 6.1 0.4 1.5 1 5.3 0.4 302 72 298 165 25.1 0 25.6 24.7 05/26/2006 14:50:00 2.6 1.1 5.7 0.4 2.5 1.2 6.1 0.4 1.5 1 4.6 0.4 292 64 297 165 25.3 0 25.6 24.7 05/26/2006 15:00:00 2.1 1.3 6.5 0.4 2.1 1.2 6.8 0.4 2 1 5.3 0.4 132 72 334 165 24.7 0.2 25.3 24.1 05/26/2006 15:10:00 1.3 0.6 3.4 0.4 1.3 0.6 3 0.4 1.3 0.6 3 0.4 146 36 165 165 23.7 0.2 24.4 23.5 05/26/2006 15:20:00 2.6 1.2 5.3 0.4 2.5 1.1 5.7 0.4 2.1 1.2 5.7 0.4 351 107 301 165 24.1 0.2 24.7 23.8 05/26/2006 15:30:00 2.5 1.4 6.8 0.4 2.4 1.3 6.1 0.4 1.9 1.3 6.1 0.4 180 102 177 165 24.3 0.2 24.7 23.8 05/26/2006 15:40:00 1.7 0.6 3.8 0.4 1.8 0.6 3.4 0.4 1.7 0.6 3.8 0.4 130 28 180 165 24.2 0.2 24.7 23.8 05/26/2006 15:50:00 1.4 0.9 4.9 0.4 1.3 0.8 4.2 0.4 1.1 0.7 3 0.4 166 69 360 165 24.5 0.3 25 24.1 05/26/2006 16:00:00 1 0.6 2.3 0.4 0.9 0.6 2.6 0.4 0.9 0.6 2.6 0.4 143 33 165 165 24.1 0.2 24.7 23.8 05/26/2006 16:10:00 1.5 0.8 4.2 0.4 1.5 0.8 4.2 0.4 1.2 0.7 4.6 0.4 148 86 328 165 24.1 0 24.4 24.1 05/26/2006 16:20:00 2.2 1.3 4.9 0.4 2.2 1.3 4.9 0.4 1.5 1 4.9 0.4 325 82 346 165 24.3 0 24.7 24.1 05/26/2006 16:30:00 1.1 0.9 4.2 0.4 1 0.8 3.4 0.4 0.8 0.6 2.6 0.4 175 82 18 165 24.1 0.1 24.4 24.1 05/26/2006 16:40:00 1.4 0.8 4.2 0.4 1.4 0.9 3.8 0.4 1.1 0.7 3 0.4 138 90 9 165 24 0 24.4 23.8 05/26/2006 16:50:00 1.8 1.1 5.3 0.4 1.7 1.2 5.3 0.4 1.5 1.1 4.6 0.4 196 79 300 165 23.8 0.2 24.4 23.5 05/26/2006 17:00:00 2.8 1.3 5.7 0.4 2.7 1.3 5.7 0.4 2 1.2 5.3 0.4 292 45 307 165 24.3 0 24.7 24.1 05/26/2006 17:10:00 3.4 1.2 5.7 0.7 3.3 1.3 5.7 0.4 1.8 1.1 4.6 0.4 291 32 309 165 24 0.1 24.7 23.8 05/26/2006 17:20:00 4.4 0.8 6.8 1.9 4.5 0.8 6.8 2.3 3.5 0.9 6.1 0.7 300 13 296 165 24.1 0.1 24.4 23.8 05/26/2006 17:30:00 4.6 0.7 6.1 2.6 4.7 0.8 6.5 2.3 3.6 0.9 5.7 0.4 305 12 300 165 24.4 0 24.7 24.4 05/26/2006 17:40:00 4.5 0.7 6.5 2.3 4.6 0.7 6.5 3 3.7 0.8 6.1 1.5 302 14 325 165 24.7 0 25.3 24.4 05/26/2006 17:50:00 4.8 0.6 6.1 2.6 4.9 0.6 6.1 3 3.7 0.8 5.7 1.9 303 10 293 165 24.7 0 25 24.4 05/26/2006 18:00:00 5.1 0.6 6.5 2.6 5.1 0.6 6.8 3 4.2 0.8 6.5 1.9 305 8 318 165 24.7 0 25.3 24.1 05/26/2006 18:10:00 5.2 0.6 7.2 3.8 5.2 0.5 7.2 3.8 4.3 0.8 6.1 2.6 305 8 302 165 24.7 0 25.3 24.7 05/26/2006 18:20:00 5.2 0.6 6.8 3.8 5.3 0.6 7.2 3.4 4 0.6 5.3 2.3 297 8 301 165 24.4 0 25.3 24.1 05/26/2006 18:30:00 5.3 0.4 6.5 4.2 5.3 0.4 6.5 4.6 4.4 0.6 5.7 3 305 5 302 165 24.1 0 24.4 24.1 05/26/2006 18:40:00 5.4 0.4 6.5 3.8 5.4 0.4 6.5 4.2 4.2 0.5 5.7 2.6 303 5 300 165 23.8 0 24.1 23.5 05/26/2006 18:50:00 5.5 0.4 6.8 4.2 5.5 0.4 6.8 4.2 4.3 0.6 5.7 3 303 5 301 165 23.5 0 24.1 23.2 05/26/2006 19:00:00 5.7 0.4 6.5 4.6 5.7 0.4 6.5 4.6 4.3 0.5 5.3 3 303 4 305 165 23.2 0 23.8 22.9 05/26/2006 19:10:00 5.5 0.5 6.5 4.2 5.5 0.5 6.5 4.2 4 0.5 5.3 2.6 300 4 312 165 22.9 0.1 23.5 22.9 05/26/2006 19:20:00 5.7 0.6 6.8 3.8 5.8 0.6 6.8 3.8 4.6 0.6 6.1 3 303 5 304 165 22.8 0.1 23.5 22.6 05/26/2006 19:30:00 6.5 0.4 7.2 5.3 6.5 0.4 7.2 5.3 4.7 0.5 6.1 3.4 303 3 307 165 22.5 0 22.6 22.3 05/26/2006 19:40:00 6.9 0.4 8 5.7 6.9 0.5 8 5.3 5.3 0.7 7.2 3.8 305 4 305 165 22.2 0 22.3 22 05/26/2006 19:50:00 7.5 0.4 8.8 6.5 7.4 0.4 8.4 6.1 6.4 0.6 7.6 4.9 310 2 310 165 22 0 22.3 21.7 05/26/2006 20:00:00 7.7 0.7 9.1 6.1 7.7 0.7 9.1 6.1 6.2 0.7 7.6 4.6 307 3 307 165 21.8 0 22 21.7 05/26/2006 20:10:00 9.1 0.7 10.7 6.8 9.1 0.8 11.1 6.5 7.3 0.9 9.5 4.9 308 5 308 165 21.6 0 21.7 21.4 05/26/2006 20:20:00 8.3 1 11.1 5.7 8.2 1 10.7 6.1 6.6 1 9.5 4.2 305 5 312 165 21.5 0 21.7 21.4 05/26/2006 20:30:00 7.4 0.7 9.9 5.7 7.4 0.7 9.9 5.7 5.7 0.9 8.4 4.2 305 6 302 165 21.2 0 21.4 21.1 05/26/2006 20:40:00 7.5 0.8 9.9 5.7 7.5 0.8 9.5 5.3 5.8 0.8 8 3.8 304 5 300 165 20.8 0 21.1 20.8 05/26/2006 20:50:00 7.3 0.6 8.8 5.7 7.3 0.6 8.4 5.7 5.6 0.7 7.6 3.8 304 4 305 165 20.6 0 20.8 20.2 05/26/2006 21:00:00 7.5 0.6 9.1 5.7 7.4 0.6 9.1 5.7 5.5 0.7 7.6 3.8 301 4 296 165 20.2 0 20.5 20 05/26/2006 21:10:00 7 1 9.1 4.6 7 1 8.8 4.6 5.1 0.8 7.2 3 300 6 294 165 19.9 0 20.2 19.7 05/26/2006 21:20:00 5.2 0.7 6.8 3 5.2 0.7 6.8 3 4.2 0.8 6.5 2.3 307 9 297 165 19.6 0 19.7 19.4 05/26/2006 21:30:00 5.1 0.7 7.2 3.4 5.1 0.7 6.8 3 4.3 0.8 6.8 2.6 308 10 315 165 19.7 0 20 19.7 05/26/2006 21:40:00 5.9 0.8 8 3.8 5.9 0.8 8 3.4 4.9 0.7 6.8 3 307 9 295 165 19.7 0 20 19.4 05/26/2006 21:50:00 5.6 0.7 7.2 3.8 5.6 0.6 7.2 3.8 4.7 0.6 6.5 3.4 310 8 292 165 19.4 0 19.7 19.1 05/26/2006 22:00:00 5.6 0.7 7.2 3 5.6 0.7 7.2 3 4.3 0.7 5.7 2.6 302 8 303 165 19.3 0 19.7 19.1 05/26/2006 22:10:00 6.4 0.5 7.6 4.9 6.4 0.6 7.6 4.6 4.6 0.6 6.5 2.6 299 5 304 165 19.4 0.2 19.7 19.1 05/26/2006 22:20:00 6.2 0.4 7.6 4.9 6.2 0.4 7.2 4.9 4.6 0.6 6.1 3.4 297 4 297 165 19.3 0 19.7 19.1 05/26/2006 22:30:00 6.5 0.5 7.6 5.3 6.4 0.5 7.2 4.9 4.9 0.6 6.8 3 297 4 297 165 19.2 0 19.4 19.1 05/26/2006 22:40:00 6.8 0.5 8 5.3 6.8 0.5 8 5.3 5 0.6 7.2 3.8 300 5 297 165 19.4 0.1 19.7 19.1 05/26/2006 22:50:00 7.1 0.6 8.4 5.7 7.1 0.6 8.4 5.7 5.2 0.6 6.8 3.8 299 4 300 165 19.7 0 20 19.4 05/26/2006 23:00:00 7.8 0.4 8.8 6.5 7.8 0.4 8.8 6.8 5.4 0.5 6.8 4.2 302 4 304 165 19.5 0 19.7 19.4 05/26/2006 23:10:00 7.4 0.5 8.4 6.1 7.4 0.5 8.4 6.5 5.7 0.7 7.6 4.2 297 4 298 165 19.7 0 20 19.7 05/26/2006 23:20:00 6.9 0.4 8 5.7 7 0.4 8 6.1 5.3 0.7 7.2 3.8 297 4 300 165 20 0 20.2 20 05/26/2006 23:30:00 7.4 0.5 8.8 6.1 7.5 0.5 8.8 6.1 5.4 0.6 7.2 4.2 298 3 303 165 19.7 0.1 20.2 19.7 05/26/2006 23:40:00 8.6 0.7 9.9 6.1 8.5 0.7 9.5 5.7 6.2 1 8.8 4.2 304 4 309 165 19.5 0.1 20 19.4 05/26/2006 23:50:00 8.3 0.6 9.9 6.5 8.2 0.6 9.9 6.1 6.2 0.8 8.4 4.2 303 5 300 165 19.6 0.1 20 19.7 05/27/2006 00:00:00 9.1 0.9 11.5 6.8 9.1 0.9 11.5 6.8 6.9 1 9.9 4.6 303 4 302 165 19.6 0 19.7 19.4 05/27/2006 00:10:00 9.1 1.1 11.5 6.8 9 1.1 11.5 6.8 7.2 1.2 10.3 4.6 304 6 301 165 19.7 0 20 19.7 05/27/2006 00:20:00 9.8 1.1 12.6 6.5 9.7 1.1 12.6 6.5 7.6 1.1 10.7 4.9 305 6 304 165 19.6 0 19.7 19.7 05/27/2006 00:30:00 10 1.2 13 6.8 9.8 1.2 12.6 6.8 8 1 10.7 4.9 304 6 296 165 19.8 0 20 19.7 05/27/2006 00:40:00 8.9 1.2 11.5 5.3 8.8 1.1 11.5 4.9 6.9 1.2 10.7 3 305 8 304 165 19.7 0 20 19.4 05/27/2006 00:50:00 8.3 1.5 13 4.6 8.3 1.4 12.2 4.6 6.5 1.3 9.5 3 304 6 303 165 19.7 0 20 19.7 05/27/2006 01:00:00 5.3 1.3 8.8 2.3 5.2 1.4 8.8 2.6 4.2 0.9 7.6 1.9 314 17 304 165 19.2 0.2 19.7 19.1 05/27/2006 01:10:00 5.9 1.6 8.8 2.6 5.9 1.6 8.8 2.6 4.8 1.1 7.2 2.6 313 15 302 165 19.2 0 19.4 19.1 05/27/2006 01:20:00 7.1 1 9.5 4.2 7.1 1 9.1 3.8 5.3 1 8.4 2.6 302 8 310 165 19.2 0 19.4 19.1 05/27/2006 01:30:00 8 1.1 11.1 5.7 7.9 1 11.1 5.3 6.2 1.1 10.3 3 295 6 299 165 19.1 0.1 19.4 19.1 05/27/2006 01:40:00 9.4 0.9 11.8 7.2 9.3 0.9 11.5 7.2 7.2 0.9 10.7 4.9 300 5 296 165 19.5 0 19.7 19.4 05/27/2006 01:50:00 9.4 0.9 11.8 6.8 9.4 0.9 11.5 6.5 7.1 0.9 9.9 4.6 302 5 304 165 19.6 0 20 19.7 05/27/2006 02:00:00 8.9 1 11.8 6.5 8.8 1 11.8 6.5 6.7 1.1 10.3 4.6 299 6 301 165 19.5 0 19.7 19.1 05/27/2006 02:10:00 7.3 1 9.9 4.6 7.3 1 9.9 4.2 5.4 1.2 8 1.9 295 8 287 165 19.2 0 19.7 19.1 05/27/2006 02:20:00 5.2 1.5 8.8 1.5 5.3 1.4 8.8 1.5 3.5 1.5 8 0.4 293 17 289 165 19 0 19.4 18.8 05/27/2006 02:30:00 5.3 1.4 8.4 1.9 5.3 1.4 8 1.1 3.4 1.4 7.2 0.4 287 21 294 165 19 0 19.1 18.8 05/27/2006 02:40:00 5.9 1.5 9.5 1.5 5.9 1.4 9.5 1.9 3.9 1.7 8.8 0.4 295 15 285 165 19.1 0 19.4 18.8 05/27/2006 02:50:00 6.5 1 9.1 2.6 6.5 1 8.8 3 5 1.2 8.8 1.5 289 10 297 165 19.2 0 19.7 19.1 05/27/2006 03:00:00 6.3 1 8.8 2.6 6.3 1 8.8 3.4 4.6 1.3 8 1.5 288 10 298 165 19.2 0 19.4 19.1 05/27/2006 03:10:00 6.7 1 9.1 3.8 6.7 0.9 9.1 4.2 5.2 1 9.1 1.9 290 9 294 165 19.2 0 19.4 19.1 05/27/2006 03:20:00 5.6 1.3 8.8 1.9 5.6 1.3 8.8 1.9 3.9 1.3 6.5 0.4 296 12 300 165 19 0 19.1 18.8 05/27/2006 03:30:00 6 1.3 9.1 2.3 5.9 1.3 9.1 1.9 4.1 1.5 8 0.4 300 12 303 165 19.2 0 19.4 18.8 05/27/2006 03:40:00 4.6 1.1 8.4 1.9 4.7 1.1 8 1.5 3.3 1.1 7.2 0.7 295 12 296 165 19.1 0 19.4 18.8 05/27/2006 03:50:00 5.3 1.2 8 1.9 5.3 1.2 7.6 2.6 4 1.5 7.2 0.7 287 13 278 165 19 0.1 19.7 18.8 05/27/2006 04:00:00 6.2 1.1 8.8 2.3 6.3 1.1 8.8 2.6 5.3 1.3 8.8 2.6 293 9 285 165 19.7 0.1 20.2 19.4 05/27/2006 04:10:00 5.3 1.2 8 2.3 5.3 1.2 8 2.6 4.3 1 6.8 2.3 298 10 295 165 20 0 20.2 19.7 05/27/2006 04:20:00 2.1 1.2 4.6 0.4 2.2 1.1 4.6 0.4 2.2 0.9 4.2 0.4 288 58 296 165 20 0 20.5 19.7 05/27/2006 04:30:00 0.5 0.3 1.9 0.4 0.6 0.4 1.9 0.4 0.6 0.4 1.9 0.4 180 76 150 165 20.2 0 20.5 20 05/27/2006 04:40:00 1.6 1 4.9 0.4 1.8 1 5.3 0.4 1.6 1 4.9 0.4 203 61 234 165 20.5 0.2 21.1 20.2 05/27/2006 04:50:00 1 0.6 2.6 0.4 1.2 0.7 3 0.4 1.2 0.5 3 0.4 222 33 222 165 20.5 0.3 21.1 20.2 05/27/2006 05:00:00 1.9 1.1 4.2 0.4 2 1.2 4.2 0.4 1.7 1 4.2 0.4 259 43 282 165 20.5 0 20.8 20.5 05/27/2006 05:10:00 4.1 1.2 6.8 0.7 4.2 1.2 6.8 1.1 3.6 1 6.5 1.5 297 15 302 165 20.4 0.1 20.8 20 05/27/2006 05:20:00 2.7 1.2 5.7 0.4 2.8 1.2 5.7 0.4 2.3 1.1 6.1 0.4 302 17 285 165 20.8 0 21.1 20.5 05/27/2006 05:30:00 1.9 0.9 4.2 0.4 2.1 1 4.9 0.4 1.9 0.9 4.6 0.4 310 32 273 165 20.8 0.1 21.1 20.8 05/27/2006 05:40:00 3.5 1.6 7.2 0.4 3.5 1.7 7.6 0.4 2.4 1.4 5.7 0.4 316 27 284 165 21.3 0 21.4 21.1 05/27/2006 05:50:00 2.2 1.7 6.5 0.4 2.3 1.6 6.5 0.4 1.8 1.2 5.7 0.4 294 64 314 165 21.5 0.2 22 21.1 05/27/2006 06:00:00 3.1 2.2 9.1 0.4 3 2.1 8.8 0.4 2.2 1.5 6.5 0.4 322 61 324 165 21.8 0 22 21.7 05/27/2006 06:10:00 5.1 2.2 9.9 0.4 4.7 2.1 9.9 0.4 3.8 2 8.8 0.4 351 51 342 165 22.1 0.1 22.3 21.7 05/27/2006 06:20:00 3.2 1.7 7.6 0.4 3 1.7 7.2 0.4 2 1.2 5.7 0.4 340 58 349 165 21.7 0.2 22.3 21.4 05/27/2006 06:30:00 4.6 2 8.8 0.4 4.4 2 8.8 0.4 3.4 1.8 8 0.4 317 39 310 165 22.4 0.4 22.9 21.7 05/27/2006 06:40:00 5.1 1.5 8.8 1.1 5 1.5 8.4 1.1 3.7 1.4 8.4 0.4 314 23 328 165 22.7 0 22.9 22.3 05/27/2006 06:50:00 5.1 1.8 10.3 1.1 5 1.8 9.9 0.7 3.9 1.8 8.4 0.4 319 24 343 165 23 0.1 23.5 22.3 05/27/2006 07:00:00 4.2 1.2 8.4 0.4 4.3 1.2 8 0.7 3.3 1.2 6.5 0.4 296 27 305 165 23 0.2 23.5 22.6 05/27/2006 07:10:00 4.5 1.5 7.6 0.7 4.6 1.5 7.6 0.7 3.7 1.4 6.8 0.4 278 23 285 165 22.5 0 22.9 22.3 05/27/2006 07:20:00 6.3 1 9.5 3.8 6.3 1 9.5 3.8 5 1.3 8.4 1.5 286 10 282 165 22.4 0 22.6 22.3 05/27/2006 07:30:00 6.6 0.8 8.8 4.2 6.6 0.7 8.8 4.2 5.3 1.1 8 2.6 293 9 292 165 22.4 0 22.9 22.3 05/27/2006 07:40:00 6.6 1 9.1 4.6 6.6 1 9.1 4.2 5.5 1.1 8.8 2.6 301 9 309 165 22.7 0.1 22.9 22.3 05/27/2006 07:50:00 7.5 0.7 9.9 5.7 7.4 0.7 9.9 5.7 6.5 0.8 9.1 3.8 311 8 303 165 22.8 0 22.9 22.6 05/27/2006 08:00:00 6.2 1.3 11.1 4.2 6.2 1.3 11.1 4.2 5.5 1.5 11.1 3 314 10 301 165 23.2 0.1 23.5 22.6 05/27/2006 08:10:00 5.9 0.8 8.4 3.8 5.9 0.8 8.4 3.8 5.4 0.8 7.2 3 317 8 318 165 23.7 0 24.4 23.5 05/27/2006 08:20:00 5.9 0.6 7.2 4.2 5.8 0.5 6.8 4.2 5.3 0.6 6.8 3 315 6 317 165 23.4 0.2 24.1 23.2 05/27/2006 08:30:00 6 0.6 8 4.6 6 0.6 8 4.6 5.2 0.7 6.8 3.8 306 9 304 165 23 0.1 23.5 22.9 05/27/2006 08:40:00 7.1 1.1 9.5 4.2 7 1.1 9.1 4.2 6 1.2 8.8 3.4 310 9 312 165 23 0 23.5 22.9 05/27/2006 08:50:00 7.8 1.1 11.1 4.9 7.8 1.1 11.1 4.6 6.8 1.1 10.3 4.2 308 6 302 165 23 0.1 23.5 22.9 05/27/2006 09:00:00 7.7 1.1 9.9 4.6 7.6 1.1 10.3 4.6 6.3 1.1 9.5 3.4 306 8 302 165 22.9 0 23.2 22.9 05/27/2006 09:10:00 7.7 1.1 12.2 4.9 7.7 1.1 11.8 4.9 6.5 1 8.8 3.8 306 9 292 165 22.8 0 23.2 22.6 05/27/2006 09:20:00 8.7 1 11.8 6.1 8.7 1.1 11.8 5.7 6.9 1 9.5 4.6 305 6 304 165 22.9 0.1 23.5 22.6 05/27/2006 09:30:00 7.9 1.2 10.7 4.2 7.9 1.2 10.7 3.8 6.6 1 9.9 4.2 306 8 302 165 22.8 0 23.2 22.6 05/27/2006 09:40:00 7.4 1.1 10.7 4.9 7.4 1.1 10.3 4.6 6.4 1 10.3 4.2 307 9 314 165 23.2 0.2 23.8 22.9 05/27/2006 09:50:00 7.1 1.3 9.9 3.8 7.1 1.3 10.3 3.8 6 1.2 9.9 3.4 308 11 307 165 23.1 0 23.5 22.9 05/27/2006 10:00:00 7.4 1.3 11.8 4.9 7.4 1.2 11.5 4.9 6.4 1.1 11.5 3.8 305 10 298 165 23.3 0 23.8 23.2 05/27/2006 10:10:00 7.6 1.2 10.7 4.2 7.6 1.2 10.7 4.2 6.1 1.2 9.9 3 305 7 289 165 23.2 0 23.5 22.9 05/27/2006 10:20:00 7.4 0.8 9.5 4.2 7.4 0.8 9.1 4.6 6.1 0.8 8.4 4.2 304 6 307 165 23.3 0 23.5 23.2 05/27/2006 10:30:00 7.3 1.3 10.7 4.2 7.4 1.3 10.7 4.6 6.1 1.1 10.7 3 304 10 289 165 23.2 0.2 23.8 22.9 05/27/2006 10:40:00 7 0.7 8.8 5.3 7 0.7 8.8 5.3 6.5 0.8 8.4 4.2 314 9 309 165 24.3 0.2 25 23.8 05/27/2006 10:50:00 6.5 1 9.5 3 6.4 1 10.3 2.6 6.2 0.9 8.4 3.8 324 11 350 165 24.8 0.3 25.3 24.4 05/27/2006 11:00:00 7.1 0.9 9.9 4.6 7.1 0.9 9.5 4.6 6.1 1 9.5 3.8 307 6 309 165 24.1 0.3 25 23.5 05/27/2006 11:10:00 6.9 1 8.8 3.8 6.9 0.9 8.8 3.8 6.3 0.9 8.4 2.6 311 6 312 165 23.8 0 24.1 23.5 05/27/2006 11:20:00 6.9 1 9.9 4.6 6.9 1 9.5 4.6 5.8 0.9 8 3.4 306 6 303 165 23.8 0 24.1 23.5 05/27/2006 11:30:00 6.8 0.6 9.1 4.9 6.8 0.6 8.8 4.9 5.7 0.9 8 3.4 304 6 303 165 23.6 0 24.1 23.5 05/27/2006 11:40:00 6.5 0.8 8 4.6 6.4 0.8 8 4.2 6 1 8 3.8 313 7 306 165 23.8 0.2 24.4 23.5 05/27/2006 11:50:00 7.1 0.5 8.4 5.7 7.1 0.5 8.8 5.3 6.7 0.7 8.4 4.9 313 5 312 165 23.8 0 24.4 23.5 05/27/2006 12:00:00 7.1 0.7 9.1 5.3 7.1 0.7 8.8 5.3 6.7 0.8 8.8 4.6 313 6 309 165 23.9 0.2 24.7 23.5 05/27/2006 12:10:00 7.4 0.6 8.8 5.7 7.3 0.6 8.8 5.7 7 0.8 9.1 5.3 316 6 324 165 24.3 0.3 25 23.8 05/27/2006 12:20:00 7.3 0.5 8.8 5.7 7.3 0.5 8.8 5.7 6.7 0.8 8.8 4.2 311 5 309 165 23.5 0.1 23.8 23.5 05/27/2006 12:30:00 7 0.5 8.4 5.3 7 0.5 8 5.3 6.8 0.7 9.1 4.9 314 4 313 165 23.4 0 23.5 23.2 05/27/2006 12:40:00 6.7 0.9 8.4 3.8 6.6 0.9 8.4 3.8 6.3 1 8.4 2.3 315 8 308 165 23.6 0.3 24.4 23.5 05/27/2006 12:50:00 6.2 0.8 8.4 4.2 6.2 0.8 8.4 4.2 5.5 0.9 7.6 3.4 311 11 313 165 24.2 0.1 24.7 23.8 05/27/2006 13:00:00 6.4 0.8 9.9 4.6 6.4 0.8 10.3 4.6 5.9 0.8 9.1 3.8 315 10 309 165 24.7 0.3 25.6 24.4 05/27/2006 13:10:00 6.2 0.9 8.4 4.2 6.1 0.9 8.4 4.2 5.5 1.1 8 3.4 311 8 309 165 24.9 0.2 25.9 24.7 05/27/2006 13:20:00 5.8 0.8 7.6 3.4 5.7 0.8 7.6 3.4 5.4 0.9 7.2 3 317 9 311 165 25.2 0.2 25.9 24.7 05/27/2006 13:30:00 5.9 0.7 7.6 3.8 5.8 0.7 7.2 3.4 5.3 0.9 7.2 3 312 7 329 165 25.1 0.5 26.2 24.4 05/27/2006 13:40:00 5.9 0.8 8 3 5.9 0.8 7.6 3 5.3 0.8 7.2 1.9 312 8 307 165 24.5 0.1 25.3 24.1 05/27/2006 13:50:00 5.9 0.6 7.2 4.2 5.9 0.7 7.6 4.2 5.6 0.8 6.8 3.4 317 8 310 165 24.5 0.1 25.3 23.8 05/27/2006 14:00:00 4.7 0.7 6.1 2.3 4.6 0.7 6.1 2.6 4.2 0.8 6.5 1.5 318 12 314 165 25.6 0.3 26.2 25 05/27/2006 14:10:00 4.3 0.6 5.7 2.6 4.3 0.6 5.7 2.6 3.7 0.7 5.7 1.5 315 11 304 165 25.7 0.1 26.2 25.6 05/27/2006 14:20:00 2.7 1.1 5.3 0.4 2.6 1.2 5.7 0.4 2.1 1.2 5.7 0.4 304 61 324 165 25.4 0.2 26.2 25.3 05/27/2006 14:30:00 2.8 0.9 4.6 0.4 2.8 1 6.5 0.4 2.1 0.9 5.3 0.4 289 36 284 165 25.4 0.1 25.6 25.3 05/27/2006 14:40:00 2.8 1 4.9 0.4 2.7 1.1 4.9 0.4 1.9 1 4.6 0.4 282 38 266 165 24.7 0.2 25.3 24.4 05/27/2006 14:50:00 3.2 1.1 6.5 0.4 3.3 1.1 6.5 0.4 2.4 1.1 6.5 0.4 298 28 305 165 25 0 25.3 25 05/27/2006 15:00:00 3.8 0.6 5.7 1.9 3.9 0.7 5.7 1.9 3 0.9 4.9 0.4 304 13 315 165 25.1 0 25.3 25 05/27/2006 15:10:00 4 0.7 5.7 2.3 4 0.7 6.5 1.9 3.1 1 5.3 0.7 302 13 314 165 25.4 0 25.6 25.3 05/27/2006 15:20:00 2.4 1.1 5.7 0.4 2.4 1.1 5.3 0.4 1.5 1.1 4.6 0.4 306 39 284 165 24.7 0.4 25.6 24.1 05/27/2006 15:30:00 1.3 0.6 3 0.4 1.3 0.6 3 0.4 1.3 0.7 3 0.4 135 49 124 165 23.6 0.1 24.1 23.2 05/27/2006 15:40:00 2.6 1.1 5.7 0.7 2.6 1.1 5.7 0.4 1.9 1.1 5.3 0.4 299 51 8 165 23.5 0.4 24.1 22.9 05/27/2006 15:50:00 1.4 0.6 3 0.4 1.4 0.6 3 0.4 1.3 0.7 3 0.4 149 53 91 165 22.9 0.2 23.5 22.6 05/27/2006 16:00:00 1.8 0.5 3 0.4 1.8 0.5 3.4 0.4 1.7 0.6 3 0.4 159 36 113 165 22.7 0.2 23.2 22 05/27/2006 16:10:00 2.3 0.4 3.4 1.5 2.3 0.4 3 1.1 2.4 0.4 3.4 1.5 142 19 139 165 22 0 22.3 21.7 05/27/2006 16:20:00 1.9 0.4 2.6 0.7 1.9 0.4 2.6 0.7 1.9 0.5 3 0.4 135 22 126 165 21.6 0 22 21.1 05/27/2006 16:30:00 1.8 0.8 3.8 0.4 1.8 0.9 3.4 0.4 1.8 1 3.8 0.4 152 16 173 165 21.2 0 21.7 21.1 05/27/2006 16:40:00 1.3 0.5 3 0.4 1.3 0.5 3 0.4 1.2 0.7 3 0.4 144 21 170 165 21.6 0 21.7 21.1 05/27/2006 16:50:00 0.9 0.9 4.2 0.4 0.8 0.8 3.8 0.4 0.7 0.5 3 0.4 149 69 334 165 21.8 0 22.3 21.4 05/27/2006 17:00:00 1 0.5 3.8 0.4 1 0.6 3.4 0.4 0.8 0.5 2.3 0.4 159 66 283 165 21.8 0 22 21.7 05/27/2006 17:10:00 1.4 0.6 2.6 0.4 1.4 0.6 2.6 0.4 1.5 0.5 2.3 0.4 160 53 127 165 21.8 0.2 22.3 21.1 05/27/2006 17:20:00 1.4 0.6 3 0.4 1.4 0.6 3 0.4 1.3 0.6 2.6 0.4 127 15 130 165 21.2 0 21.4 21.1 05/27/2006 17:30:00 0.8 0.5 2.3 0.4 0.8 0.5 2.6 0.4 0.9 0.5 2.3 0.4 124 27 157 165 21.6 0 21.7 21.4 05/27/2006 17:40:00 1 0.5 2.3 0.4 1.1 0.5 2.3 0.4 0.9 0.5 2.6 0.4 103 29 29 165 21.3 0 21.7 21.1 05/27/2006 17:50:00 2.4 1 4.9 0.4 2.3 0.9 4.6 0.4 2.1 1 4.2 0.4 21 27 20 165 22.1 0.2 22.6 21.4 05/27/2006 18:00:00 2.1 0.9 3.8 0.4 1.9 0.9 4.2 0.4 1.5 0.8 3.4 0.4 52 49 16 165 21.8 0.1 22.3 21.4 05/27/2006 18:10:00 2.3 0.5 3.8 0.7 2.2 0.5 3.4 0.7 1.9 0.7 3.8 0.4 30 15 20 165 21.8 0 22 21.4 05/27/2006 18:20:00 2.1 0.5 3 1.1 2.1 0.5 3 1.1 2.3 0.4 3 1.5 40 10 45 165 21.2 0 21.7 21.1 05/27/2006 18:30:00 2.2 0.4 3.4 1.1 2.1 0.4 3 1.1 2.1 0.4 3 1.1 27 9 37 165 21.2 0 21.4 21.1 05/27/2006 18:40:00 1.8 0.5 3 0.4 1.6 0.5 2.6 0.4 1.7 0.5 2.6 0.4 5 18 13 165 21.5 0.1 22 21.1 05/27/2006 18:50:00 2.1 0.3 3 1.1 1.9 0.4 2.6 0.7 2.1 0.3 3 1.5 343 10 338 165 22.1 0 22.3 21.7 05/27/2006 19:00:00 2.2 0.3 3 0.7 1.8 0.5 3.4 0.7 1.9 0.5 3 0.4 341 17 306 165 22.1 0 22.3 22 05/27/2006 19:10:00 3 0.6 4.2 1.5 3 0.6 4.6 1.5 2.6 0.6 4.2 1.1 311 10 310 165 21.9 0 22.3 21.7 05/27/2006 19:20:00 3.4 0.8 5.3 1.5 3.4 0.8 5.3 1.5 2.7 0.8 4.9 0.7 302 12 292 165 21.4 0 21.7 21.1 05/27/2006 19:30:00 3.9 0.5 5.3 2.3 3.9 0.5 5.7 2.3 3.3 0.5 4.9 1.9 301 8 307 165 21.5 0 21.7 21.1 05/27/2006 19:40:00 4.7 1.1 7.6 2.3 4.6 1.3 7.6 1.5 4 0.9 6.5 2.3 315 20 302 165 21.3 0 21.4 21.1 05/27/2006 19:50:00 4.2 0.7 5.7 1.1 4.1 0.7 5.7 1.5 4.1 0.6 5.3 2.3 332 16 322 165 20.8 0.2 21.1 20.5 05/27/2006 20:00:00 4 0.5 5.3 2.3 4 0.5 5.3 2.3 3.4 0.6 5.3 1.9 311 15 331 165 20.4 0 20.8 20.2 05/27/2006 20:10:00 3.4 0.5 5.3 2.3 3.4 0.5 5.3 2.3 2.9 0.5 4.2 1.5 309 11 304 165 20.2 0 20.5 20 05/27/2006 20:20:00 3.5 0.5 4.9 2.3 3.4 0.5 4.9 2.3 2.7 0.5 4.2 1.5 305 7 310 165 20 0 20.2 20 05/27/2006 20:30:00 3.9 0.5 5.3 2.6 3.8 0.6 5.7 1.9 3.1 0.6 4.9 1.5 312 9 309 165 19.8 0 20 19.7 05/27/2006 20:40:00 4.8 0.8 6.8 2.6 4.8 0.8 6.8 2.6 4.2 0.9 6.5 1.9 317 10 319 165 19.5 0.1 20 19.4 05/27/2006 20:50:00 5.9 1 8.8 4.2 5.8 1 8.4 3.8 5.3 0.9 7.6 3 318 9 334 165 19.3 0 19.4 19.1 05/27/2006 21:00:00 5.7 0.8 7.6 3.8 5.6 0.8 7.6 3.8 5 0.9 7.2 2.6 316 8 318 165 19.1 0 19.4 18.8 05/27/2006 21:10:00 5.4 0.6 7.2 3.8 5.3 0.6 7.2 3.8 4.5 0.7 6.5 2.6 308 9 341 165 18.9 0 19.1 18.8 05/27/2006 21:20:00 7.1 1 9.1 4.6 7 1 8.8 4.6 5.9 1.1 8.4 3 310 8 312 165 18.5 0.1 19.1 18.2 05/27/2006 21:30:00 8.5 1 10.7 5.7 8.4 0.9 10.3 5.7 8 0.9 10.3 5.7 320 9 321 165 18.4 0 18.5 18 05/27/2006 21:40:00 7.7 0.8 10.3 5.7 7.6 0.8 9.9 5.7 7.5 0.8 9.9 5.3 330 10 319 165 18.3 0 18.5 18.2 05/27/2006 21:50:00 8.3 0.9 10.3 5.7 8.2 0.9 10.7 6.1 7.7 0.9 10.3 5.7 326 11 337 165 18.5 0 18.8 18.2 05/27/2006 22:00:00 8.2 1.1 10.7 4.9 8 1.2 10.7 4.6 7.8 1.1 10.7 5.7 331 11 318 165 18.4 0.1 18.8 18 05/27/2006 22:10:00 8.4 1.2 11.1 5.7 8.3 1.3 11.5 3.8 8 1.2 11.5 5.3 333 11 323 165 18.9 0.1 19.1 18.5 05/27/2006 22:20:00 8.4 1.8 14.1 4.9 7.8 1.9 13.3 3.4 8.1 1.7 13.3 4.9 343 15 350 165 18.5 0 18.8 18.2 05/27/2006 22:30:00 9.2 1.2 12.6 6.1 8.9 1.3 12.6 4.6 9.1 1.2 11.8 6.5 338 11 341 165 18.9 0 19.1 18.8 05/27/2006 22:40:00 9.5 1.6 14.5 5.7 9 1.8 14.9 4.9 9 1.6 12.6 4.9 341 13 342 165 19 0 19.4 18.8 05/27/2006 22:50:00 10.1 1.7 16.1 6.5 9.5 1.7 16.1 4.6 9.5 1.7 14.9 6.1 345 16 1 165 19 0 19.4 18.8 05/27/2006 23:00:00 11.8 2.2 18.3 7.6 10.8 2.2 17.2 6.1 11.5 2.2 18.3 6.8 344 13 13 165 19.1 0 19.4 18.8 05/27/2006 23:10:00 13.5 1.7 17.9 10.3 11.5 2.3 17.9 6.5 13.3 1.7 18.3 9.5 354 11 10 165 19.3 0 19.4 19.1 05/27/2006 23:20:00 12.3 1.5 16.8 8 10.6 2 16.4 6.1 12 1.5 16.8 8.4 356 11 352 165 19.1 0.1 19.7 19.1 05/27/2006 23:30:00 12.6 2.1 18.3 8.4 11 2 17.2 6.1 12.5 2.2 18.7 8 350 13 356 165 19.1 0 19.4 19.1 05/27/2006 23:40:00 13 1.7 17.6 8.8 12.3 2.2 17.9 6.8 12.3 1.7 17.6 8 347 8 343 165 19 0 19.4 18.8 05/27/2006 23:50:00 12.5 1.6 17.2 8.4 11 2.1 17.2 5.3 12.3 1.7 16.4 7.2 349 11 352 165 19 0 19.4 19.1 05/28/2006 00:00:00 9.1 1.3 12.6 6.5 8.5 1.4 12.2 4.9 8.7 1.1 13 6.1 344 11 340 165 18.7 0.2 19.4 18.2 05/28/2006 00:10:00 9 1.2 12.6 6.5 8.5 1.2 13 4.9 8.6 1.3 13.3 5.3 339 13 356 165 18.5 0 18.8 18.2 05/28/2006 00:20:00 9 1.4 12.2 5.7 8.6 1.7 12.2 3.8 8.5 1.3 11.8 5.3 336 15 327 165 18.5 0 18.8 18.5 05/28/2006 00:30:00 9.5 1.5 14.1 6.1 9.4 1.5 14.1 6.1 9.4 1.5 13.7 6.5 331 11 319 165 18.8 0 19.1 18.5 05/28/2006 00:40:00 8.2 1.1 11.5 5.7 8.1 1.2 11.1 5.3 8 1.2 11.1 4.9 336 9 337 165 18.8 0 19.1 18.5 05/28/2006 00:50:00 8.9 1.2 13 5.7 8.5 1.5 12.6 4.9 8.9 1.2 11.8 6.1 343 9 349 165 18.7 0 19.1 18.5 05/28/2006 01:00:00 8.1 1.2 11.1 4.2 8 1.5 11.5 4.2 8.1 1.2 11.1 4.6 336 12 342 165 18.6 0 18.8 18.2 05/28/2006 01:10:00 8.1 0.9 10.3 6.1 7.7 1.2 10.3 3.8 8 1 10.7 5.7 337 13 349 165 18.6 0 18.8 18.5 05/28/2006 01:20:00 8.9 0.9 11.5 6.5 8.9 1 11.5 6.5 8.9 1 12.2 6.8 339 8 337 165 18.6 0 18.8 18.5 05/28/2006 01:30:00 9.5 0.7 12.2 7.6 9.6 0.8 11.8 7.6 9.4 0.8 11.8 7.2 340 6 340 165 18.6 0.1 19.1 18.5 05/28/2006 01:40:00 8.1 1.1 11.1 5.3 7.7 1.2 10.7 3.8 8.1 1.2 11.5 4.9 345 10 331 165 18.5 0 18.8 18.2 05/28/2006 01:50:00 8.3 1 11.5 6.1 8.3 1.2 12.6 5.3 8.5 1.1 12.6 6.5 343 8 347 165 18.5 0 18.8 18.5 05/28/2006 02:00:00 8.6 1 11.1 6.5 8.3 1.3 11.8 4.9 8.7 1 11.5 6.1 345 8 353 165 18.5 0 18.8 18.5 05/28/2006 02:10:00 8.7 0.8 11.1 6.8 8 1.5 11.8 4.2 8.8 0.9 11.8 6.8 350 6 349 165 18.2 0 18.5 18 05/28/2006 02:20:00 8.8 0.9 11.1 6.8 8.3 1.5 11.5 4.2 9 0.9 11.5 6.8 347 8 2 165 18.4 0.1 18.5 18.2 05/28/2006 02:30:00 8.2 1 11.1 5.3 7.3 1.3 10.7 3.8 8.2 1 10.7 6.1 349 8 353 165 18.2 0 18.5 18 05/28/2006 02:40:00 7.9 0.7 9.9 6.1 7.8 1 9.9 4.2 7.9 0.6 9.9 6.1 343 7 350 165 17.9 0 18.2 17.4 05/28/2006 02:50:00 7.6 0.7 9.1 5.7 7.2 1.1 9.1 3.8 7.6 0.8 9.5 5.3 346 7 341 165 17.8 0 18 17.4 05/28/2006 03:00:00 6.5 0.8 8.4 4.6 6.1 0.9 8.4 3.8 6.5 0.8 8.8 4.9 344 9 359 165 17.8 0 18 17.4 05/28/2006 03:10:00 5 0.6 6.5 3.8 4.1 1.2 6.8 1.9 5.1 0.6 6.8 3.8 353 11 340 165 17.4 0.1 17.7 17.1 05/28/2006 03:20:00 5.9 1 9.1 3.8 5.2 1.5 8.8 2.3 5.7 0.9 8.4 3.8 351 10 350 165 17.4 0 17.4 17.1 05/28/2006 03:30:00 5.3 0.6 6.8 3 5.1 0.8 6.5 2.6 5.2 0.5 6.5 3.8 345 7 347 165 17.1 0 17.4 16.8 05/28/2006 03:40:00 4.7 0.6 6.5 3.4 4.3 1 6.5 1.9 4.6 0.6 6.5 3.4 346 9 349 165 16.8 0 17.1 16.3 05/28/2006 03:50:00 5.3 0.8 7.2 3 5.1 1 7.2 2.6 5.2 0.7 6.8 3.4 342 10 351 165 16.6 0 16.8 16.6 05/28/2006 04:00:00 5.7 0.8 7.2 4.2 5.5 1.2 8 2.6 5.5 0.8 7.6 3.8 344 8 342 165 16.6 0 16.8 16.6 05/28/2006 04:10:00 4.9 0.6 6.5 3.4 4.2 1 6.8 2.3 4.9 0.6 6.5 3.8 350 6 334 165 16.8 0 16.8 16.8 05/28/2006 04:20:00 4.8 0.8 6.5 3 3.5 0.9 5.7 1.9 4.8 0.8 6.8 3 356 7 357 165 16.6 0 17.1 16.6 05/28/2006 04:30:00 6.2 0.5 7.6 4.9 4.9 1 7.2 2.6 6.3 0.5 7.6 4.9 353 5 355 165 16.6 0 16.8 16.6 05/28/2006 04:40:00 5.4 0.5 7.2 4.6 4.2 1 6.8 1.9 5.6 0.5 7.2 4.6 353 6 349 165 16.6 0 16.8 16.6 05/28/2006 04:50:00 4.9 0.5 6.1 3.8 4.6 0.9 6.5 2.3 4.9 0.5 6.5 4.2 344 8 334 165 16.8 0 16.8 16.8 05/28/2006 05:00:00 5 0.5 6.1 3.8 4.9 0.6 6.1 2.3 5 0.5 6.1 3.4 343 7 333 165 16.9 0 17.1 16.8 05/28/2006 05:10:00 5.4 0.7 7.6 3.8 5.2 1.1 6.8 2.3 5.3 0.7 7.2 3.4 345 7 344 165 17 0 17.1 16.8 05/28/2006 05:20:00 4.7 0.7 7.2 3.4 4.1 1.2 7.2 1.9 4.8 0.6 7.2 3.8 351 6 344 165 17 0 17.1 16.8 05/28/2006 05:30:00 5.6 0.7 8 3.8 4.5 1 7.2 1.5 5.6 0.7 7.6 3.8 353 5 350 165 17.3 0 17.4 17.1 05/28/2006 05:40:00 5.6 0.9 8 4.2 4.6 1.1 8 2.3 5.5 0.8 8 3.8 353 7 10 165 17.4 0 17.7 16.8 05/28/2006 05:50:00 4.9 0.8 7.6 3.4 4 1.2 7.2 1.5 5 0.7 7.6 3.8 355 9 25 165 17.6 0 17.7 17.1 05/28/2006 06:00:00 4.3 1 6.5 3 3 1.1 6.8 1.5 4.3 1 7.6 2.6 357 6 350 165 17.8 0 18.2 17.4 05/28/2006 06:10:00 3.3 0.8 6.1 1.9 2.5 1.1 6.1 0.7 3.1 0.8 6.1 1.5 357 10 336 165 18.5 0.1 18.8 18 05/28/2006 06:20:00 3.9 0.6 6.1 2.6 3.5 0.8 5.7 1.9 3.9 0.6 5.7 2.6 348 8 333 165 18.4 0 18.5 18.2 05/28/2006 06:30:00 2.5 1 4.6 1.1 1.9 1 4.2 0.4 2.5 1.1 4.9 0.7 351 8 358 165 18.8 0.2 19.4 18.5 05/28/2006 06:40:00 2.1 0.6 3.8 1.1 1.7 0.9 3.8 0.4 2 0.5 3.8 1.1 19 16 29 165 19.6 0 20 19.4 05/28/2006 06:50:00 4.1 0.4 5.3 3 4 0.6 5.3 1.9 4.3 0.5 5.3 3 25 9 16 165 18.7 0.3 19.7 18.5 05/28/2006 07:00:00 3.8 0.3 4.9 3 3.1 0.6 4.6 1.5 4.1 0.3 4.9 2.6 13 7 27 165 18.7 0 19.1 18.5 05/28/2006 07:10:00 3.6 0.3 4.6 3 2.5 0.5 3.8 1.5 3.8 0.4 4.6 3 360 7 359 165 19 0 19.4 18.8 05/28/2006 07:20:00 3.5 0.3 4.2 2.6 3.1 0.6 4.2 1.5 3.6 0.4 4.2 2.6 20 8 19 165 19.1 0 19.4 19.1 05/28/2006 07:30:00 3.7 0.5 4.6 2.6 3.7 0.5 4.6 2.6 3.8 0.4 4.9 2.6 41 6 32 165 18.7 0.2 19.4 18.5 05/28/2006 07:40:00 3.2 0.4 4.6 2.3 3.3 0.4 4.6 2.3 3.1 0.4 3.8 1.9 48 6 48 165 18.7 0 18.8 18.5 05/28/2006 07:50:00 2.5 0.8 4.6 0.4 2.5 0.7 4.2 0.7 2.3 0.7 4.6 0.7 71 35 90 165 19.4 0.4 20.2 18.8 05/28/2006 08:00:00 2.2 0.5 3.4 1.1 2.3 0.5 3.4 1.1 2.1 0.5 3.8 0.7 68 38 67 165 19.7 0.1 20 19.4 05/28/2006 08:10:00 2.9 0.5 4.2 1.5 2.9 0.5 4.2 1.5 2.8 0.6 4.2 1.5 38 13 39 165 19.9 0 20.2 19.4 05/28/2006 08:20:00 4 0.6 5.3 2.3 3.9 0.6 5.3 2.3 3.9 0.8 5.3 1.9 36 10 36 165 19.5 0.3 20 18.8 05/28/2006 08:30:00 4.4 0.4 5.3 3.4 4.4 0.4 5.3 3 4.4 0.5 5.7 3 39 6 39 165 18.5 0.2 18.8 18.2 05/28/2006 08:40:00 3.9 0.5 5.3 2.6 4 0.5 5.3 2.6 3.9 0.5 5.7 2.6 43 8 37 165 18.1 0 18.5 18 05/28/2006 08:50:00 3 0.9 5.3 0.7 3.1 0.8 5.3 1.1 2.8 0.9 4.9 0.4 60 26 65 165 18.8 0.4 19.7 18.2 05/28/2006 09:00:00 3.5 1 6.1 0.7 3.5 1.1 6.5 0.4 3.2 1.2 6.5 0.4 91 26 106 165 19.7 0.2 20.5 19.4 05/28/2006 09:10:00 3.1 0.8 5.3 0.4 3.1 0.9 5.3 0.4 3 0.9 4.9 0.7 119 22 116 165 19.6 0.3 20.2 19.1 05/28/2006 09:20:00 3.9 0.9 6.1 1.5 3.9 0.9 6.5 1.1 3.8 0.9 6.5 1.1 119 15 93 165 19.5 0 19.7 19.1 05/28/2006 09:30:00 3.7 0.8 6.1 1.1 3.7 0.8 5.7 1.1 3.5 0.9 5.3 0.7 120 18 124 165 19.1 0 19.4 18.8 05/28/2006 09:40:00 4.8 0.8 6.5 2.3 4.8 0.8 6.8 2.6 4.7 0.7 6.5 2.6 122 9 128 165 19.4 0 19.7 19.1 05/28/2006 09:50:00 4.5 0.8 6.1 2.3 4.6 0.8 6.5 2.3 4.5 0.9 6.5 1.1 122 12 122 165 19.2 0 19.7 18.8 05/28/2006 10:00:00 4 0.6 5.7 2.6 4 0.6 5.7 2.3 4 0.6 5.3 2.3 128 11 111 165 19 0.1 19.4 18.8 05/28/2006 10:10:00 4 0.7 5.7 2.3 4.1 0.8 6.1 1.9 4.1 0.8 6.1 1.9 133 12 113 165 19.4 0.1 19.7 18.8 05/28/2006 10:20:00 3.9 0.8 5.7 2.3 4 0.8 6.1 1.9 4 0.8 6.1 1.5 129 12 137 165 19.4 0 19.7 19.1 05/28/2006 10:30:00 4.7 0.9 6.5 2.3 4.7 0.9 6.5 1.9 4.6 0.8 6.5 2.6 124 13 132 165 19.3 0 19.7 19.1 05/28/2006 10:40:00 4.3 0.6 6.1 3 4.3 0.6 6.5 3 4.3 0.7 6.5 2.3 122 9 126 165 19.2 0 19.7 19.1 05/28/2006 10:50:00 4.6 0.7 6.1 2.3 4.7 0.7 6.5 2.6 4.5 0.8 6.8 2.6 119 10 130 165 19.2 0 19.4 19.1 05/28/2006 11:00:00 4.3 0.8 6.1 1.9 4.4 0.8 6.1 1.9 4.3 0.7 6.5 2.3 122 13 131 165 19.5 0.1 19.7 19.1 05/28/2006 11:10:00 4.2 0.8 6.1 1.9 4.3 0.8 6.1 2.3 4.2 0.8 6.1 2.6 117 11 115 165 19.6 0.1 20 19.1 05/28/2006 11:20:00 4.2 0.6 5.7 2.6 4.3 0.6 6.1 2.6 4.1 0.7 5.7 2.3 117 9 108 165 19.7 0.2 20.2 19.4 05/28/2006 11:30:00 4.2 0.7 6.1 2.6 4.3 0.7 6.1 2.6 4.2 0.6 5.7 2.6 111 9 115 165 20 0.3 20.5 19.4 05/28/2006 11:40:00 4.8 0.7 7.6 2.3 4.9 0.7 7.2 3 4.7 0.9 7.6 2.3 103 11 77 165 20 0.3 20.8 19.4 05/28/2006 11:50:00 3.3 0.8 5.3 1.1 3.4 0.8 5.7 1.1 3.1 0.8 4.9 0.4 71 22 59 165 19.8 0.3 20.5 19.1 05/28/2006 12:00:00 3.5 0.7 5.7 1.5 3.6 0.7 6.5 1.1 3.3 0.6 5.7 1.1 61 23 80 165 19.7 0.1 20 19.4 05/28/2006 12:10:00 3.4 0.8 5.7 1.1 3.5 0.7 5.7 0.7 3.1 0.7 4.6 1.1 81 38 87 165 20.1 0.1 20.5 19.7 05/28/2006 12:20:00 3.5 0.6 5.3 1.9 3.5 0.6 4.9 2.3 3.6 0.7 5.3 1.9 108 10 110 165 19.6 0.1 20 19.4 05/28/2006 12:30:00 4.3 0.6 6.1 2.6 4.4 0.6 5.7 2.6 4.3 0.7 6.1 2.6 119 9 122 165 19.5 0 20 19.1 05/28/2006 12:40:00 3.9 0.6 5.7 2.3 4 0.6 6.1 2.6 4.1 0.6 6.5 3 126 9 119 165 19.5 0.1 19.7 19.1 05/28/2006 12:50:00 4.1 0.6 5.7 2.6 4.1 0.6 5.7 3 4.2 0.8 6.5 2.3 128 11 123 165 19.5 0 20 19.4 05/28/2006 13:00:00 4.2 0.5 5.7 2.6 4.2 0.5 5.7 2.6 4.3 0.6 6.1 3 138 8 136 165 19.2 0.2 19.7 18.8 05/28/2006 13:10:00 3.8 0.6 6.1 2.6 3.8 0.7 6.5 2.3 3.9 0.6 6.5 2.6 136 13 133 165 19 0 19.4 18.5 05/28/2006 13:20:00 4.7 0.7 6.5 2.6 4.7 0.7 6.5 2.6 4.7 0.7 6.5 2.3 140 12 131 165 19 0.1 19.4 18.5 05/28/2006 13:30:00 4.7 0.7 6.5 2.6 4.6 0.7 6.5 2.6 4.7 0.8 6.5 2.3 153 13 148 165 18.6 0.3 19.4 18.2 05/28/2006 13:40:00 4.7 0.7 6.8 3 4.7 0.7 6.8 3 4.8 0.8 6.8 3 147 10 157 165 19 0.3 19.7 18.2 05/28/2006 13:50:00 4.2 0.7 6.5 2.3 4.2 0.7 6.1 2.3 4.2 0.7 6.1 1.9 151 13 156 165 18.3 0.4 19.1 17.7 05/28/2006 14:00:00 4.1 0.5 5.7 3 4 0.6 5.7 2.6 4.2 0.6 5.7 3 141 12 149 165 18 0.3 18.5 17.4 05/28/2006 14:10:00 4.3 0.6 5.7 3 4.3 0.6 5.7 3 4.3 0.6 6.1 3 142 8 145 165 18.1 0 18.5 17.7 05/28/2006 14:20:00 4.9 0.6 6.1 3.4 4.9 0.6 6.1 3.4 4.7 0.7 6.5 2.6 139 10 135 165 18.1 0.1 18.5 17.7 05/28/2006 14:30:00 4.3 0.7 6.1 2.6 4.3 0.7 6.5 2.6 4.3 0.7 6.1 2.3 141 9 144 165 17.8 0.2 18.2 17.1 05/28/2006 14:40:00 4 0.6 5.7 2.6 4 0.6 5.3 1.9 4.1 0.6 5.7 2.3 142 11 124 165 17.7 0.2 18 17.1 05/28/2006 14:50:00 3.5 0.8 5.3 1.9 3.5 0.7 5.7 1.9 3.5 0.8 5.3 1.9 146 13 156 165 17.8 0 18 17.4 05/28/2006 15:00:00 3.6 0.7 4.9 1.1 3.6 0.7 5.3 1.1 3.7 0.7 5.7 1.5 142 15 149 165 17.7 0 18 17.4 05/28/2006 15:10:00 3.9 0.6 5.3 2.6 3.9 0.6 5.7 2.6 4 0.6 5.3 3 141 10 131 165 17.7 0 18 17.4 05/28/2006 15:20:00 4.9 0.7 7.2 3 5 0.7 7.2 3 5 0.7 6.8 3 122 8 121 165 18.1 0.2 18.8 17.4 05/28/2006 15:30:00 4.7 0.6 6.8 3 4.8 0.6 6.8 2.6 4.7 0.7 6.8 2.6 125 9 122 165 17.8 0 18 17.7 05/28/2006 15:40:00 4.3 0.7 6.8 3 4.4 0.7 6.8 2.3 4.5 0.8 6.8 2.6 130 8 127 165 18 0.1 18.2 17.7 05/28/2006 15:50:00 4.6 0.6 6.1 3.4 4.6 0.6 6.1 3 4.7 0.5 6.5 3.4 145 14 119 165 17.5 0.5 18.2 16.6 05/28/2006 16:00:00 4.1 0.5 5.3 3 4.1 0.5 5.7 2.6 4.1 0.5 5.3 2.6 149 9 136 165 16.4 0 16.8 16.3 05/28/2006 16:10:00 3.7 0.7 6.1 2.3 3.7 0.7 5.7 1.9 3.8 0.8 5.7 1.9 144 11 153 165 16.4 0.2 16.8 16 05/28/2006 16:20:00 3.5 0.5 4.9 2.3 3.5 0.5 4.9 2.3 3.7 0.5 4.9 2.6 146 12 145 165 16 0 16.3 15.7 05/28/2006 16:30:00 3.5 0.7 5.3 1.9 3.5 0.7 4.9 1.9 3.7 0.7 5.3 1.9 148 8 154 165 16 0 16.3 15.7 05/28/2006 16:40:00 2.9 1 4.9 1.1 2.9 1 4.9 0.7 3 1 4.9 0.7 144 9 140 165 16 0 16.3 16 05/28/2006 16:50:00 4 0.5 5.3 2.6 4 0.5 5.3 2.6 4.1 0.6 5.3 2.3 148 9 141 165 15.7 0.3 16.6 15.2 05/28/2006 17:00:00 3.8 0.5 4.9 2.6 3.8 0.5 4.9 2.6 3.8 0.5 4.9 2.3 148 8 148 165 15.1 0.1 15.5 14.9 05/28/2006 17:10:00 3.9 0.5 5.3 2.6 3.8 0.5 5.3 2.3 4 0.5 5.3 3 155 9 158 165 14.8 0.1 15.5 14.6 05/28/2006 17:20:00 4 0.5 5.3 2.3 3.9 0.5 5.3 2.6 3.9 0.5 5.7 2.6 145 6 132 165 14.6 0 14.6 14.4 05/28/2006 17:30:00 3.9 0.4 4.9 2.6 3.9 0.4 4.9 2.6 3.9 0.4 4.9 2.6 138 7 144 165 14.5 0 14.9 14.1 05/28/2006 17:40:00 3.2 0.6 4.6 1.9 3.2 0.6 4.9 1.9 3.3 0.6 4.6 1.9 142 9 151 165 14.4 0 14.9 14.1 05/28/2006 17:50:00 2.2 0.3 3 1.5 2.2 0.3 3 1.5 2.2 0.4 3 1.1 133 9 114 165 14.6 0 14.9 14.6 05/28/2006 18:00:00 1.5 0.4 3 0.7 1.4 0.4 2.6 0.7 1.2 0.6 3 0.4 143 15 144 165 15 0.3 16 14.4 05/28/2006 18:10:00 1.6 0.2 1.9 1.5 1.5 0.2 1.9 1.1 1.4 0.3 1.9 0.4 166 1 164 165 16.6 0.4 17.1 15.7 05/28/2006 18:20:00 1.8 0.3 2.3 1.5 1.7 0.3 2.3 1.1 1.6 0.3 2.3 0.4 162 3 162 165 17.3 0.1 17.4 16.8 05/28/2006 18:30:00 2.2 0.4 3 1.1 2.1 0.4 3 1.1 1.7 0.4 2.6 0.7 143 9 127 165 16.3 0.8 17.4 14.9 05/28/2006 18:40:00 2.4 0.2 3 1.9 2.4 0.2 2.6 1.9 2.3 0.2 2.6 1.5 146 7 143 165 15.7 0.7 16.8 14.6 05/28/2006 18:50:00 2.2 0.3 2.6 1.1 2.1 0.3 2.6 1.1 1.9 0.4 2.6 1.1 145 12 141 165 14.7 0.7 16.3 14.1 05/28/2006 19:00:00 2.4 0.2 2.6 1.9 2.3 0.2 2.6 1.9 2.2 0.2 2.6 1.9 159 1 157 165 15.7 0.7 16.6 13.8 05/28/2006 19:10:00 2.4 0.2 2.6 1.9 2.3 0.3 2.6 1.9 2.2 0.3 2.6 1.5 162 2 162 165 16.4 0 16.6 16.3 05/28/2006 19:20:00 2.1 0.2 2.6 1.9 2 0.2 2.6 1.5 2 0.3 2.6 0.7 166 5 165 165 16.4 0 16.8 16.3 05/28/2006 19:30:00 1.9 0.3 2.3 1.1 1.8 0.3 2.3 1.1 1.9 0.3 2.3 1.5 182 8 173 165 16.4 0 16.8 16.3 05/28/2006 19:40:00 2 0.2 2.3 1.5 1.9 0.2 2.3 1.5 2 0.2 2.3 1.5 180 3 177 165 16.3 0 16.6 16.3 05/28/2006 19:50:00 2.4 0.2 3 1.9 2.3 0.2 2.6 1.9 2.4 0.2 2.6 1.9 180 1 179 165 16.1 0 16.6 16 05/28/2006 20:00:00 2.2 0.3 2.6 1.5 2.1 0.3 3 1.5 2 0.3 2.6 1.1 181 7 177 165 16.1 0 16.3 16 05/28/2006 20:10:00 2.2 0.2 2.6 1.9 2 0.2 2.6 1.5 2 0.2 2.6 1.1 179 4 196 165 15.8 0.1 16 15.7 05/28/2006 20:20:00 1.7 0.3 2.3 1.1 1.5 0.3 2.3 1.1 1.5 0.4 2.3 0.7 180 2 179 165 15.2 0.2 15.7 14.9 05/28/2006 20:30:00 1.6 0.2 1.9 1.1 1.5 0.2 1.9 1.1 1.5 0.2 1.9 1.1 169 4 172 165 15.5 0 15.7 14.9 05/28/2006 20:40:00 2 0.2 2.6 1.5 1.9 0.2 2.6 1.5 1.7 0.3 2.6 0.7 168 4 165 165 15.6 0 15.7 15.5 05/28/2006 20:50:00 1.9 0.2 2.3 1.5 1.8 0.2 2.3 1.1 1.9 0.2 2.3 1.1 175 3 179 165 15.2 0 15.5 14.9 05/28/2006 21:00:00 1.9 0.2 2.3 1.5 1.8 0.2 2.3 1.5 1.9 0.2 2.3 1.1 175 5 182 165 15.2 0 15.2 14.9 05/28/2006 21:10:00 1.4 0.2 1.9 1.1 1.3 0.2 1.9 0.7 1.4 0.2 1.9 0.7 172 6 175 165 15 0 15.5 14.6 05/28/2006 21:20:00 1.4 0.2 1.9 1.1 1.3 0.2 1.9 1.1 1.3 0.2 1.9 0.7 173 8 165 165 14.6 0 15.2 14.4 05/28/2006 21:30:00 1.3 0.3 1.9 0.4 1.3 0.3 1.9 0.4 1.1 0.3 1.5 0.4 191 2 192 165 14.1 0.1 14.6 13.8 05/28/2006 21:40:00 1.4 0.4 1.9 0.7 1.3 0.4 1.9 0.7 0.8 0.3 1.5 0.4 193 5 197 165 13.7 0.1 14.1 13.3 05/28/2006 21:50:00 1.2 0.4 2.3 0.4 1.1 0.5 2.3 0.4 1.1 0.5 2.3 0.4 161 10 145 165 13.4 0.1 13.8 13 05/28/2006 22:00:00 2.6 0.7 3.8 1.5 2.6 0.7 3.8 1.5 2.5 0.6 3.8 1.5 136 8 128 165 12.6 0.3 13.5 11.9 05/28/2006 22:10:00 3.3 0.4 3.8 2.3 3.3 0.4 3.8 2.3 3.1 0.5 3.8 1.9 150 8 135 165 11.9 0.2 12.2 10.9 05/28/2006 22:20:00 3.2 0.2 3.8 2.6 3.1 0.2 3.8 2.6 2.8 0.2 3.4 2.3 158 7 157 165 10.7 0.2 11.9 10.6 05/28/2006 22:30:00 2.6 0.4 3.4 1.9 2.6 0.4 3.4 1.9 2.3 0.5 3.4 1.5 162 5 164 165 11.1 0.3 11.7 10.9 05/28/2006 22:40:00 2.3 0.4 3 1.5 2.2 0.4 3 1.1 1.9 0.4 2.6 1.1 160 9 162 165 10.8 0.5 11.9 10.3 05/28/2006 22:50:00 2.8 0.4 3.4 1.9 2.7 0.4 3.4 1.9 2.5 0.4 3.4 1.5 151 13 130 165 11 0.5 12.2 10.3 05/28/2006 23:00:00 2.6 0.3 3 2.3 2.5 0.3 3 2.3 2.4 0.2 3 1.9 160 11 161 165 12.3 0.3 12.7 11.4 05/28/2006 23:10:00 3 0.5 4.2 1.9 3 0.5 4.2 1.9 2.9 0.5 3.8 1.5 148 16 135 165 10.5 0.4 11.4 10.1 05/28/2006 23:20:00 2.7 0.3 3.4 2.3 2.6 0.3 3.4 2.3 2.3 0.2 3 1.9 158 8 164 165 10.7 0.3 11.4 10.3 05/28/2006 23:30:00 3 0.4 3.8 2.3 3 0.4 3.8 2.3 2.9 0.4 3.8 2.3 136 11 137 165 10.2 0 10.6 10.1 05/28/2006 23:40:00 3.6 0.6 4.9 2.6 3.6 0.6 4.6 2.3 3.5 0.6 4.6 2.3 136 4 135 165 10.1 0 10.3 9.8 05/28/2006 23:50:00 3.3 0.6 4.6 1.9 3.3 0.6 4.6 1.9 3.2 0.6 4.2 1.9 135 3 137 165 10.1 0.1 10.6 9.6 05/29/2006 00:00:00 3.6 0.6 4.6 2.3 3.6 0.5 4.6 2.3 3.5 0.6 4.6 2.3 136 5 139 165 10.4 0 10.6 10.1 05/29/2006 00:10:00 3.6 0.3 4.2 3 3.6 0.3 4.2 3 3.3 0.3 3.8 2.6 145 3 145 165 10.6 0.1 10.9 10.3 05/29/2006 00:20:00 4 0.2 4.6 3.8 4 0.2 4.6 3.4 3.8 0.2 4.2 3.4 142 3 142 165 10.8 0 11.1 10.6 05/29/2006 00:30:00 4.3 0.3 4.9 3.8 4.2 0.2 4.9 3.8 4 0.2 4.6 3.4 142 2 146 165 10.8 0 11.1 10.6 05/29/2006 00:40:00 4.2 0.3 4.9 3.4 4.1 0.3 4.6 3.4 3.9 0.3 4.6 3.4 148 4 145 165 11 0 11.1 10.6 05/29/2006 00:50:00 3.9 0.2 4.2 3.4 3.8 0.2 4.2 3.4 3.6 0.2 4.2 3 153 2 158 165 10.9 0.1 11.1 10.6 05/29/2006 01:00:00 3.9 0.4 4.6 2.3 3.8 0.4 4.6 1.9 3.5 0.4 4.2 2.3 153 5 160 165 10.9 0 11.1 10.3 05/29/2006 01:10:00 3.9 0.3 4.6 3 3.7 0.3 4.6 3 3.5 0.4 4.2 2.6 161 3 161 165 11.2 0.1 11.7 10.9 05/29/2006 01:20:00 3.8 0.4 4.2 2.6 3.7 0.4 4.2 2.6 3.4 0.3 4.2 2.6 158 3 158 165 11.3 0.1 11.7 10.9 05/29/2006 01:30:00 3.8 0.4 4.6 2.6 3.7 0.4 4.2 2.6 3.7 0.5 4.6 2.3 161 15 161 165 11.3 0.1 11.7 10.9 05/29/2006 01:40:00 3.7 0.3 4.2 2.6 3.5 0.3 4.6 2.6 3.5 0.4 4.2 2.6 166 3 164 165 11.7 0.1 11.9 11.1 05/29/2006 01:50:00 3.2 0.4 3.8 2.3 3.1 0.3 3.8 2.3 2.9 0.4 3.8 1.9 167 4 164 165 11.9 0 12.2 11.7 05/29/2006 02:00:00 2.6 0.2 3 1.9 2.6 0.2 3 1.9 2.4 0.4 3 1.1 175 2 175 165 12.1 0 12.2 11.9 05/29/2006 02:10:00 2.6 0.6 3.4 1.5 2.6 0.5 3.4 1.9 2.6 0.5 3.4 1.9 169 6 162 165 12.2 0 12.5 11.9 05/29/2006 02:20:00 3.5 0.3 4.2 3 3.4 0.3 4.2 3 3.4 0.2 3.8 3 160 3 159 165 12 0 12.5 11.9 05/29/2006 02:30:00 3.7 0.3 4.6 3 3.7 0.3 4.2 3 3.5 0.3 4.2 2.6 146 6 150 165 11.9 0 12.2 11.9 05/29/2006 02:40:00 3.7 0.3 4.6 3 3.7 0.3 4.6 3 3.6 0.4 4.6 2.6 131 4 131 165 11.5 0 11.9 11.4 05/29/2006 02:50:00 3.2 0.4 4.2 2.3 3.2 0.4 4.2 2.3 3.2 0.4 4.2 2.6 130 6 135 165 11.3 0 11.7 11.1 05/29/2006 03:00:00 3.2 0.3 3.8 2.6 3.2 0.3 4.2 2.6 3.2 0.3 4.2 2.3 126 6 133 165 11 0.1 11.4 10.9 05/29/2006 03:10:00 2.5 0.2 3 1.9 2.5 0.2 3 2.3 2.6 0.2 3 1.9 128 5 122 165 10.7 0.1 10.9 10.6 05/29/2006 03:20:00 2.6 0.3 3.4 2.3 2.6 0.3 3.4 2.3 2.7 0.2 3.4 2.3 131 4 133 165 10.5 0 10.9 10.3 05/29/2006 03:30:00 2.7 0.4 3.4 1.9 2.7 0.4 3.8 1.9 2.7 0.4 3.4 1.9 137 5 130 165 10.3 0 10.9 10.3 05/29/2006 03:40:00 3 0.3 3.8 2.3 3 0.3 3.8 2.3 3 0.3 3.8 2.3 133 6 128 165 10.1 0 10.3 9.8 05/29/2006 03:50:00 3.2 0.3 3.8 2.6 3.2 0.3 3.8 2.6 3.2 0.3 3.8 2.6 135 5 134 165 9.9 0.2 10.3 9.3 05/29/2006 04:00:00 3.7 0.3 4.2 2.6 3.7 0.3 4.2 3 3.6 0.3 4.2 3 134 4 125 165 9.6 0.1 9.8 9.3 05/29/2006 04:10:00 3.9 0.4 5.3 2.6 3.9 0.4 4.9 3 3.9 0.4 4.9 3 143 6 145 165 9.6 0.1 9.8 9.3 05/29/2006 04:20:00 4 0.4 5.3 3 4 0.4 4.9 3 3.9 0.3 4.9 3 148 6 156 165 9.5 0.1 9.8 9 05/29/2006 04:30:00 3.9 0.4 4.9 3 3.9 0.4 4.9 3 3.8 0.4 4.9 3 148 5 149 165 9.3 0 9.6 9 05/29/2006 04:40:00 3.2 0.3 4.2 2.6 3.2 0.3 4.2 2.6 3.1 0.3 3.8 2.3 151 5 154 165 9 0.1 9.6 8.5 05/29/2006 04:50:00 4 0.5 5.3 2.6 3.9 0.5 4.9 3 3.8 0.4 4.9 2.6 149 5 147 165 9 0.2 9.3 8.5 05/29/2006 05:00:00 4.1 0.5 5.3 3 4.1 0.5 5.3 3 4 0.4 4.9 3 147 5 147 165 9.2 0.1 9.3 8.8 05/29/2006 05:10:00 4 0.5 5.3 3 4 0.5 5.3 3 3.9 0.4 4.9 3 145 5 141 165 9.2 0 9.6 8.8 05/29/2006 05:20:00 4.3 0.4 5.3 3.4 4.4 0.4 5.3 3.4 4.2 0.4 4.9 3.4 143 4 147 165 9.4 0.1 9.6 9 05/29/2006 05:30:00 4.7 0.4 5.7 3.8 4.7 0.4 5.7 3.8 4.6 0.4 5.7 3.8 145 4 151 165 9.2 0.1 9.6 8.8 05/29/2006 05:40:00 4.5 0.6 5.7 3 4.5 0.6 5.7 3 4.2 0.5 5.3 3 150 5 150 165 9.5 0.1 9.8 9.3 05/29/2006 05:50:00 3.9 0.5 4.9 2.6 3.9 0.5 5.3 2.6 3.7 0.4 5.3 2.6 146 9 143 165 9.8 0 9.8 9.3 05/29/2006 06:00:00 4.4 0.4 5.7 3.4 4.3 0.4 5.3 3.4 4.2 0.4 5.3 3.4 147 5 147 165 9.6 0.2 9.8 9 05/29/2006 06:10:00 5 0.5 6.1 3.8 4.9 0.5 6.1 3.8 4.7 0.4 5.7 3.8 145 4 145 165 9.9 0.2 10.3 9.3 05/29/2006 06:20:00 5.2 0.4 6.1 4.2 5.1 0.4 6.1 4.2 4.9 0.4 5.7 3.8 146 5 148 165 10.1 0.1 10.3 9.6 05/29/2006 06:30:00 5.5 0.5 6.5 3.8 5.4 0.5 6.5 3.8 5.3 0.5 6.1 3.4 148 5 151 165 10.2 0 10.6 10.3 05/29/2006 06:40:00 5.1 0.5 6.5 3.8 5.1 0.5 6.5 4.2 5.1 0.5 6.1 4.2 148 7 148 165 10.4 0 10.6 10.3 05/29/2006 06:50:00 4.4 0.6 5.3 2.6 4.3 0.6 5.3 2.6 4.3 0.5 5.3 3 153 5 151 165 10.5 0 10.9 10.6 05/29/2006 07:00:00 4.2 0.4 5.3 3 4.2 0.4 5.3 3 4.2 0.4 5.7 3 149 8 147 165 10.8 0 11.1 10.9 05/29/2006 07:10:00 4.3 0.4 4.9 3.4 4.2 0.3 4.9 3.4 4.2 0.4 4.9 3.4 152 5 152 165 11 0 11.4 10.9 05/29/2006 07:20:00 4.2 0.3 4.9 3.4 4.2 0.3 4.9 3.4 4.2 0.3 4.9 3.4 149 5 154 165 11.1 0 11.4 10.6 05/29/2006 07:30:00 4.2 0.4 4.9 3 4.2 0.4 4.9 3 4.2 0.4 5.7 3 143 6 140 165 11.1 0 11.4 10.9 05/29/2006 07:40:00 5 0.4 6.1 4.2 5 0.4 6.1 4.2 5 0.4 6.1 3.4 140 4 145 165 11.2 0.1 11.4 10.9 05/29/2006 07:50:00 5.1 0.4 5.7 4.2 5 0.4 6.1 4.2 5.1 0.4 6.5 3.8 139 5 140 165 10.9 0.1 11.1 10.3 05/29/2006 08:00:00 5.7 0.5 6.8 3.8 5.7 0.5 6.8 3.8 5.6 0.5 6.8 3.8 141 5 136 165 10.8 0.1 11.1 10.6 05/29/2006 08:10:00 5.9 0.6 7.2 4.2 5.8 0.6 7.2 4.2 5.9 0.6 7.2 4.6 147 5 138 165 11.2 0.2 11.9 10.9 05/29/2006 08:20:00 5.9 0.5 6.8 4.6 5.9 0.4 6.8 4.6 5.8 0.5 6.8 4.2 144 7 146 165 11.5 0 11.9 11.1 05/29/2006 08:30:00 5.6 0.7 7.2 3.4 5.6 0.7 7.2 3.4 5.6 0.6 7.2 4.6 147 9 141 165 11.1 0 11.7 10.9 05/29/2006 08:40:00 6.1 0.6 7.6 4.2 6 0.6 7.2 4.2 6 0.7 7.6 4.2 141 6 141 165 11.2 0.1 11.7 10.9 05/29/2006 08:50:00 6 0.8 8.4 4.2 6 0.8 8 4.2 5.9 0.8 8.4 4.2 138 10 118 165 11.3 0.3 11.9 10.9 05/29/2006 09:00:00 6.1 0.5 7.6 4.6 6.1 0.5 7.6 4.6 6.1 0.6 7.6 4.6 139 8 128 165 11.3 0.3 11.9 10.6 05/29/2006 09:10:00 6.5 0.8 8 4.6 6.4 0.8 8 4.6 6.5 0.8 8.8 4.6 144 10 126 165 11.3 0.1 11.9 10.9 05/29/2006 09:20:00 6.7 0.6 8 4.9 6.7 0.6 8.4 4.9 6.6 0.7 8 4.9 140 8 133 165 10.1 0.4 11.4 9.6 05/29/2006 09:30:00 6.6 0.6 8.4 4.9 6.6 0.6 9.1 4.9 6.6 0.6 8.4 4.9 142 7 145 165 9.4 0 9.8 9 05/29/2006 09:40:00 5.8 0.6 7.2 4.2 5.8 0.6 6.8 4.2 5.9 0.6 7.2 4.2 141 7 144 165 9.2 0.1 9.6 8.8 05/29/2006 09:50:00 5.4 0.5 6.8 3.8 5.4 0.5 6.8 4.2 5.4 0.5 6.8 3.8 141 7 145 165 9.7 0.1 10.1 9 05/29/2006 10:00:00 5.1 0.5 6.5 3.8 5.2 0.5 6.5 3.8 5.2 0.6 6.5 3 140 8 148 165 9.9 0.2 10.3 9.3 05/29/2006 10:10:00 5.1 0.6 7.2 3.4 5.1 0.6 7.2 3.4 5.2 0.7 7.2 3.8 142 11 134 165 9.8 0.1 10.3 9.3 05/29/2006 10:20:00 5.1 0.6 7.6 3.8 5.1 0.6 7.6 3.8 5.2 0.6 7.2 3.8 139 9 128 165 10.5 0.2 10.9 9.8 05/29/2006 10:30:00 5.8 0.8 8 4.2 5.8 0.8 8.4 4.2 5.9 0.7 8 4.2 137 7 145 165 10.4 0.2 10.9 10.1 05/29/2006 10:40:00 6.7 0.6 8.4 5.3 6.7 0.6 8.4 5.7 6.7 0.6 8.4 4.9 140 5 130 165 10.7 0.1 10.9 10.3 05/29/2006 10:50:00 7.4 0.5 8.8 6.1 7.4 0.5 8.8 5.7 7.6 0.6 9.1 6.1 140 5 145 165 10.6 0 10.9 10.3 05/29/2006 11:00:00 7.6 0.5 9.1 6.1 7.6 0.6 9.5 5.7 7.7 0.6 9.5 5.7 138 6 137 165 10.5 0 10.9 10.3 05/29/2006 11:10:00 7.7 0.5 9.1 5.7 7.7 0.5 9.5 5.3 7.8 0.6 9.9 6.5 142 6 139 165 10.4 0 10.9 10.1 05/29/2006 11:20:00 7.4 0.6 9.1 5.7 7.3 0.6 8.8 5.7 7.5 0.6 9.1 5.3 140 4 138 165 10.5 0.2 10.9 9.6 05/29/2006 11:30:00 6.7 0.7 8.4 4.9 6.7 0.7 8.4 4.6 6.8 0.7 8.8 4.9 139 6 138 165 10 0 10.3 9.8 05/29/2006 11:40:00 6 0.6 7.6 3.4 5.9 0.6 7.6 3.4 6 0.6 8 3.8 142 7 144 165 10.1 0 10.6 9.8 05/29/2006 11:50:00 6.1 0.6 8 4.6 6.1 0.6 8 4.2 6.1 0.7 8 4.2 137 8 129 165 10.5 0 10.9 10.3 05/29/2006 12:00:00 6 0.6 7.6 4.6 6 0.6 8 4.6 6 0.6 8.4 4.6 135 7 133 165 10.3 0.1 10.9 10.1 05/29/2006 12:10:00 6.2 0.6 8 4.9 6.2 0.7 8 4.6 6.2 0.7 8.8 4.9 139 7 143 165 10.4 0.1 10.9 10.1 05/29/2006 12:20:00 6.2 0.5 7.6 5.3 6.2 0.5 8 4.9 6.3 0.6 8 4.9 140 6 145 165 10.7 0.2 11.1 10.6 05/29/2006 12:30:00 6.5 0.6 8.4 4.9 6.4 0.6 8 4.9 6.6 0.6 8.8 4.9 140 8 140 165 10.7 0 11.1 10.6 05/29/2006 12:40:00 6.6 0.6 8.4 4.6 6.5 0.6 8.4 4.9 6.6 0.6 8.4 5.3 143 7 152 165 10.5 0 10.9 10.3 05/29/2006 12:50:00 6.4 0.6 8 4.6 6.4 0.6 8.4 4.9 6.4 0.6 8.4 4.9 127 7 126 165 10.7 0.2 11.1 10.3 05/29/2006 13:00:00 6.5 0.5 8 4.9 6.6 0.6 8 4.9 6.5 0.6 8.8 4.6 129 9 125 165 10.5 0.2 11.1 10.3 05/29/2006 13:10:00 6.5 0.6 8 4.9 6.5 0.7 8.4 4.6 6.7 0.7 8.8 4.9 146 7 147 165 10.9 0 11.1 10.6 05/29/2006 13:20:00 6.4 0.6 8.4 4.6 6.4 0.7 8.4 4.6 6.5 0.6 8 4.9 138 7 124 165 11.2 0 11.7 11.1 05/29/2006 13:30:00 6 0.8 8 3.4 6 0.9 8 3.4 6 0.8 8.4 3.8 139 10 128 165 11.5 0.2 11.9 10.9 05/29/2006 13:40:00 6.4 0.6 8.8 4.2 6.4 0.7 8.8 4.2 6.5 0.6 8 4.2 134 10 121 165 11.5 0.4 12.2 10.9 05/29/2006 13:50:00 6.5 0.7 8.8 4.6 6.6 0.8 8.4 4.2 6.6 0.8 8.4 4.2 132 9 128 165 11 0.2 11.4 10.9 05/29/2006 14:00:00 6.9 0.7 8.8 5.3 6.9 0.8 8.8 4.9 6.9 0.8 9.1 4.9 134 7 128 165 10.9 0 11.1 10.3 05/29/2006 14:10:00 6.7 0.8 9.1 4.9 6.6 0.8 9.1 5.3 6.7 0.8 9.1 4.9 141 9 127 165 11.1 0 11.4 10.6 05/29/2006 14:20:00 6.7 0.6 9.5 4.6 6.6 0.6 9.5 4.9 6.7 0.6 9.1 4.6 142 7 129 165 10.8 0.1 11.4 10.3 05/29/2006 14:30:00 6.3 0.5 7.2 4.9 6.2 0.5 7.6 4.9 6.3 0.6 7.6 4.9 141 7 128 165 10.7 0 11.1 10.3 05/29/2006 14:40:00 6 0.6 7.2 4.6 5.9 0.6 7.2 4.6 6 0.6 7.6 4.6 144 8 146 165 10.7 0.1 10.9 10.3 05/29/2006 14:50:00 5.4 0.5 6.5 3.8 5.3 0.5 6.8 3.8 5.3 0.5 6.8 4.2 147 13 151 165 10.4 0.1 10.9 10.1 05/29/2006 15:00:00 5.5 0.6 6.8 3.8 5.5 0.6 7.2 3.8 5.4 0.6 6.8 3.8 138 12 119 165 10.7 0 11.1 10.6 05/29/2006 15:10:00 4.7 0.5 6.1 3.4 4.7 0.5 6.1 3.4 4.8 0.5 6.5 3.8 143 9 144 165 10.6 0 11.1 10.3 05/29/2006 15:20:00 4.3 0.5 5.3 3 4.3 0.5 5.3 2.6 4.3 0.5 5.7 3 148 9 151 165 10.4 0.1 10.9 10.3 05/29/2006 15:30:00 4.6 0.5 5.7 3 4.6 0.5 5.7 2.6 4.7 0.5 5.7 3 143 7 146 165 10.6 0 10.9 10.3 05/29/2006 15:40:00 5 0.5 6.5 3.4 5 0.5 6.5 3.4 5 0.6 6.8 3.4 140 8 147 165 10.3 0.1 10.9 10.3 05/29/2006 15:50:00 4.4 0.4 5.7 3 4.4 0.5 5.7 3 4.5 0.5 5.7 3.4 143 6 152 165 10.3 0 10.9 9.8 05/29/2006 16:00:00 4.7 0.4 5.7 3.8 4.6 0.3 5.7 3.8 4.7 0.4 5.7 3.8 145 6 138 165 10.1 0.1 10.6 9.8 05/29/2006 16:10:00 4.3 0.4 5.7 3.4 4.3 0.4 5.7 3 4.4 0.4 5.7 3 152 7 153 165 10.1 0.2 10.6 9.6 05/29/2006 16:20:00 4.3 0.4 5.3 3 4.2 0.4 5.3 3.4 4.3 0.4 5.3 3 157 5 165 165 10 0.1 10.6 9.6 05/29/2006 16:30:00 4.3 0.3 5.3 3.4 4.2 0.3 5.3 3.4 4.4 0.3 4.9 3.4 155 6 155 165 9.9 0 10.3 9.6 05/29/2006 16:40:00 4.3 0.3 5.3 3.4 4.3 0.3 5.3 3.8 4.3 0.3 5.3 3.4 151 4 151 165 10 0.1 10.3 9.6 05/29/2006 16:50:00 3.6 0.4 4.6 2.3 3.6 0.4 4.2 2.3 3.6 0.4 4.6 2.6 152 5 161 165 9.6 0.1 9.8 9 05/29/2006 17:00:00 3 0.4 4.2 1.9 3 0.5 4.6 1.9 3.1 0.5 4.2 1.9 149 6 148 165 9.6 0.2 9.8 9 05/29/2006 17:10:00 2.3 0.3 3 1.5 2.3 0.3 3 1.5 2.4 0.4 3.4 1.5 149 9 149 165 9.6 0.1 9.8 9 05/29/2006 17:20:00 2.8 0.5 3.8 1.5 2.8 0.5 3.8 1.5 2.8 0.6 4.2 0.7 149 8 164 165 9.8 0 10.3 9.3 05/29/2006 17:30:00 3.1 0.5 4.6 2.3 3.2 0.5 4.9 2.3 3.2 0.5 4.6 2.3 148 15 136 165 9.6 0.1 9.8 9.3 05/29/2006 17:40:00 3.7 0.4 4.6 2.6 3.8 0.4 4.6 2.6 3.7 0.4 4.6 2.6 132 12 130 165 9.5 0.1 9.6 9 05/29/2006 17:50:00 3.6 0.4 4.9 2.6 3.7 0.5 5.3 2.6 3.7 0.5 5.3 2.6 131 10 145 165 9.4 0 9.8 9 05/29/2006 18:00:00 4.2 0.4 5.3 3 4.3 0.4 5.7 3.4 4.2 0.4 5.3 3.4 131 9 120 165 9.4 0 9.6 9.3 05/29/2006 18:10:00 4.2 0.4 5.3 3.4 4.3 0.4 5.3 3.4 4.2 0.4 5.3 3 145 10 143 165 9.4 0 9.6 9 05/29/2006 18:20:00 4.4 0.4 5.3 3.4 4.4 0.4 5.3 3.4 4.4 0.4 5.3 3.8 143 5 137 165 9.2 0 9.6 9 05/29/2006 18:30:00 4.4 0.4 4.9 3.4 4.4 0.4 5.3 3 4.4 0.4 5.3 3.4 137 4 143 165 9.2 0 9.3 9 05/29/2006 18:40:00 4.4 0.3 4.9 3.4 4.4 0.3 5.3 3.4 4.4 0.4 5.3 3.8 145 6 139 165 9.3 0 9.6 9 05/29/2006 18:50:00 4.3 0.4 5.3 3.4 4.4 0.4 5.3 3.4 4.4 0.4 5.3 3.4 144 6 141 165 9.2 0 9.6 9 05/29/2006 19:00:00 4 0.3 4.6 3 4 0.3 4.9 3 4.1 0.4 4.9 2.6 148 3 150 165 9.1 0 9.3 8.8 05/29/2006 19:10:00 4.2 0.3 4.9 3.4 4.2 0.3 4.9 3 4.1 0.4 4.9 2.6 140 5 147 165 9 0.1 9.3 8.8 05/29/2006 19:20:00 3.9 0.4 4.6 2.6 4 0.4 4.9 2.6 4 0.4 4.9 3 140 8 136 165 9 0.1 9.3 8.5 05/29/2006 19:30:00 3.8 0.3 4.6 3 3.7 0.3 4.6 3 3.8 0.3 4.6 3 151 9 164 165 8.9 0 9.3 8.5 05/29/2006 19:40:00 3.4 0.6 4.6 1.9 3.3 0.6 4.6 1.9 3.4 0.6 4.6 1.9 153 5 160 165 8.8 0 9 8.5 05/29/2006 19:50:00 3.1 0.3 3.8 2.6 3.1 0.3 3.8 2.3 3.1 0.3 4.6 2.3 142 5 142 165 8.7 0 8.8 8.3 05/29/2006 20:00:00 3.5 0.3 4.6 3 3.5 0.3 4.6 3 3.6 0.3 4.6 3 143 4 139 165 8.6 0 8.8 8.3 05/29/2006 20:10:00 3.5 0.3 4.2 2.6 3.5 0.3 4.2 2.6 3.5 0.3 4.2 2.6 142 2 142 165 8.5 0 8.8 8.5 05/29/2006 20:20:00 2.9 0.3 3.8 2.3 3 0.3 3.8 2.3 3 0.4 4.2 2.3 145 3 144 165 8.4 0 8.5 8.3 05/29/2006 20:30:00 2.3 0.2 3 1.9 2.3 0.2 3 1.9 2.3 0.2 2.6 1.9 145 5 150 165 8.4 0 8.8 8.3 05/29/2006 20:40:00 1.8 0.3 2.6 1.1 1.8 0.3 2.6 1.1 1.9 0.3 2.6 1.5 134 4 143 165 8.3 0 8.5 8 05/29/2006 20:50:00 1.7 0.3 2.3 1.1 1.7 0.3 2.3 1.1 1.8 0.3 2.3 0.7 126 5 122 165 8 0.1 8.3 7.5 05/29/2006 21:00:00 1.3 0.2 1.5 0.7 1.2 0.2 1.5 0.7 1.3 0.2 1.9 1.1 124 5 129 165 7.7 0.1 8 7.3 05/29/2006 21:10:00 1.3 0.2 1.9 0.7 1.3 0.2 1.9 0.7 1.4 0.2 1.9 0.7 118 0 118 165 7.5 0.1 8 7 05/29/2006 21:20:00 2 0.5 3 1.1 2.1 0.5 3 1.1 2.1 0.4 3 1.1 121 4 128 165 7.4 0.1 7.8 7 05/29/2006 21:30:00 2.1 0.4 2.6 1.5 2.1 0.3 3 1.5 2.1 0.4 2.6 0.7 126 7 129 165 7.5 0.1 7.8 7 05/29/2006 21:40:00 1.8 0.3 2.6 1.1 1.9 0.3 2.6 1.1 1.9 0.4 2.6 1.1 111 4 117 165 7.4 0 7.8 7.3 05/29/2006 21:50:00 2.6 0.2 3 2.3 2.6 0.2 3 2.3 2.6 0.2 3 2.3 131 5 135 165 7.4 0 8 7.3 05/29/2006 22:00:00 2.7 0.3 3.4 1.9 2.8 0.3 3.4 1.9 2.7 0.3 3 1.5 140 2 140 165 7.4 0 7.5 7.3 05/29/2006 22:10:00 2.9 0.3 3.4 1.9 2.8 0.3 3.4 1.9 2.8 0.3 3.4 1.9 146 3 145 165 7.4 0 8 7.3 05/29/2006 22:20:00 3.9 0.5 4.9 3 3.8 0.5 4.9 3 3.8 0.5 4.9 2.6 149 2 150 165 7.3 0 7.5 7 05/29/2006 22:30:00 4.2 0.4 4.9 3 4.1 0.4 4.9 3 4.2 0.4 4.9 3 152 3 148 165 7.4 0 7.5 7.3 05/29/2006 22:40:00 2.9 0.5 3.8 1.5 2.9 0.5 3.8 1.5 2.8 0.5 3.8 1.9 158 5 150 165 7.4 0 7.8 7.3 05/29/2006 22:50:00 2.4 0.4 3 1.1 2.5 0.4 3 1.5 2.4 0.4 3.4 1.5 168 9 169 165 7.5 0 8 7.3 05/29/2006 23:00:00 2.9 0.4 3.8 1.9 2.9 0.4 4.2 1.9 3 0.4 4.2 1.9 166 3 165 165 7.6 0 7.8 7.3 05/29/2006 23:10:00 3.4 0.2 4.2 2.6 3.4 0.2 3.8 3 3.6 0.2 4.2 3 163 8 165 165 7.4 0 7.5 7.3 05/29/2006 23:20:00 3.6 0.4 4.2 3 3.6 0.4 4.2 3 3.6 0.3 4.2 3 160 15 163 165 7.3 0.1 7.5 7 05/29/2006 23:30:00 3.9 0.2 4.2 3.4 3.9 0.2 4.2 3.4 3.8 0.2 4.2 3.4 156 2 159 165 7.2 0 7.5 7 05/29/2006 23:40:00 3.3 0.3 3.8 2.6 3.3 0.3 3.8 2.6 3.4 0.3 4.2 2.6 159 2 157 165 7.3 0 7.5 7 05/29/2006 23:50:00 3.2 0.2 3.8 2.6 3.2 0.2 3.8 2.6 3.2 0.3 3.8 2.6 161 2 160 165 7.3 0 7.5 7 05/30/2006 00:00:00 2.7 0.3 3.4 1.9 2.8 0.3 3.4 2.3 2.8 0.3 3.4 2.3 161 2 162 165 7.2 0 7.5 7 05/30/2006 00:10:00 2.3 0.2 2.6 1.9 2.4 0.2 2.6 1.9 2.3 0.2 2.6 1.9 157 4 163 165 7.1 0 7.3 6.7 05/30/2006 00:20:00 2.2 0.3 2.6 1.5 2.4 0.2 3 1.9 2.4 0.3 3 1.9 151 4 148 165 7.1 0 7.3 6.7 05/30/2006 00:30:00 2.5 0.2 3 1.9 2.6 0.2 3 2.3 2.5 0.2 3 2.3 143 2 142 165 7.1 0 7.3 6.7 05/30/2006 00:40:00 2.3 0.3 3 1.5 2.4 0.2 3 1.9 2.3 0.2 2.6 1.9 150 5 146 165 7.1 0.1 7.3 6.7 05/30/2006 00:50:00 2.4 0.3 3 1.5 2.6 0.3 3.4 1.9 2.5 0.3 3 1.9 148 3 147 165 7 0.1 7.3 6.5 05/30/2006 01:00:00 2.4 0.2 2.6 1.5 2.6 0.2 3 1.9 2.5 0.2 3 1.9 151 3 154 165 7 0.1 7.3 6.5 05/30/2006 01:10:00 2.9 0.3 3.4 2.3 3.1 0.3 3.8 2.3 2.8 0.3 3.4 2.3 148 2 149 165 7 0.1 7.3 6.2 05/30/2006 01:20:00 2.6 0.3 3.4 1.9 2.8 0.3 3.4 2.3 2.6 0.2 3 2.3 150 5 145 165 7 0.1 7.3 6.2 05/30/2006 01:30:00 2.5 0.2 3 1.9 2.7 0.2 3.4 2.3 2.7 0.2 3.4 2.3 156 3 150 165 7.1 0.2 7.5 6.5 05/30/2006 01:40:00 2.3 0.3 3 1.9 2.5 0.2 3 1.9 2.6 0.2 3 1.9 162 7 157 165 7.3 0.2 7.5 7 05/30/2006 01:50:00 1.6 0.4 2.6 0.4 2 0.4 2.6 0.7 2 0.4 2.6 0.4 160 8 171 165 7.4 0.1 7.5 7 05/30/2006 02:00:00 0.5 0.3 1.5 0.4 0.8 0.4 1.9 0.4 1.1 0.3 1.9 0.4 164 17 165 165 7.3 0.1 7.5 7 05/30/2006 02:10:00 1.1 0.6 2.6 0.4 1.5 0.5 2.6 0.4 1.5 0.4 2.6 0.7 177 16 157 165 7.3 0.1 7.5 7 05/30/2006 02:20:00 0.4 0 0.7 0.4 0.5 0.2 1.1 0.4 0.8 0.3 1.5 0.4 195 6 194 165 7.1 0.2 7.5 6.5 05/30/2006 02:30:00 0.4 0 0.4 0.4 0.4 0 0.7 0.4 0.4 0.2 1.1 0.4 179 7 165 165 7.1 0.2 7.3 6.7 05/30/2006 02:40:00 0.4 0 0.4 0.4 0.5 0.3 1.5 0.4 0.6 0.3 1.5 0.4 177 1 165 165 7.1 0.1 7.5 6.7 05/30/2006 02:50:00 0.4 0.1 1.1 0.4 0.5 0.3 1.5 0.4 0.6 0.3 1.5 0.4 222 14 224 165 7.1 0 7.3 6.7 05/30/2006 03:00:00 0.6 0.5 2.6 0.4 0.9 0.6 2.6 0.4 0.9 0.6 2.3 0.4 186 11 160 165 7.2 0 7.5 6.7 05/30/2006 03:10:00 1.4 0.6 2.6 0.4 1.7 0.5 3 0.4 1.8 0.5 3 0.7 162 8 158 165 7.3 0.1 7.5 6.7 05/30/2006 03:20:00 0.6 0.3 1.9 0.4 1.1 0.4 1.9 0.4 1.3 0.4 2.3 0.4 160 6 157 165 7.3 0.1 7.5 7 05/30/2006 03:30:00 0.8 0.6 2.6 0.4 1 0.6 3 0.4 1 0.6 2.3 0.4 141 21 148 165 7.3 0.1 7.5 6.7 05/30/2006 03:40:00 0.6 0.4 2.3 0.4 1.1 0.5 2.6 0.4 1.1 0.4 2.3 0.4 119 22 150 165 7.3 0 7.5 6.7 05/30/2006 03:50:00 1 0.6 2.3 0.4 1.3 0.6 2.6 0.4 1.4 0.5 2.3 0.4 126 13 118 165 7.3 0 7.5 6.7 05/30/2006 04:00:00 1.5 0.5 3 0.4 1.9 0.5 3 0.4 1.9 0.5 3 0.7 131 17 106 165 7.2 0 7.5 6.5 05/30/2006 04:10:00 1.7 0.5 3.4 0.4 2 0.5 3.4 0.4 2.1 0.4 3.4 0.7 135 14 123 165 7.1 0 7.3 6.5 05/30/2006 04:20:00 1.1 0.6 2.6 0.4 1.4 0.7 2.6 0.4 1.6 0.5 2.6 0.4 144 17 139 165 7.1 0 7.3 6.5 05/30/2006 04:30:00 1 0.5 2.3 0.4 1.3 0.6 2.3 0.4 1.4 0.5 2.6 0.4 137 12 132 165 7.1 0.1 7.3 6.2 05/30/2006 04:40:00 0.6 0.4 2.3 0.4 0.7 0.5 2.6 0.4 1 0.5 1.9 0.4 159 35 177 165 7.1 0.1 7.3 6.5 05/30/2006 04:50:00 0.8 0.4 1.9 0.4 1.1 0.5 2.3 0.4 1.2 0.5 2.3 0.4 106 8 114 165 7.1 0.1 7.3 6.7 05/30/2006 05:00:00 0.6 0.4 2.3 0.4 0.7 0.5 2.3 0.4 1 0.5 2.3 0.4 138 10 139 165 7.2 0.1 7.5 6.7 05/30/2006 05:10:00 1.1 0.6 2.6 0.4 1.4 0.6 3 0.4 1.7 0.5 3 0.7 160 7 141 165 7.2 0.1 7.5 6.7 05/30/2006 05:20:00 1.5 0.6 3 0.4 1.7 0.5 3 0.4 2 0.4 3 1.1 166 8 165 165 7.2 0.1 7.5 6.7 05/30/2006 05:30:00 1.2 0.6 2.6 0.4 1.4 0.6 2.6 0.4 1.7 0.5 2.6 0.4 164 4 165 165 7.2 0.1 7.5 6.7 05/30/2006 05:40:00 0.7 0.4 1.9 0.4 1 0.4 2.3 0.4 1.3 0.3 1.9 0.7 156 7 154 165 7.1 0.1 7.5 6.7 05/30/2006 05:50:00 1.8 0.4 2.6 0.7 2 0.4 3 1.1 2.1 0.3 3 1.5 153 9 164 165 7.1 0.2 7.5 6.7 05/30/2006 06:00:00 1.4 0.6 2.6 0.4 1.7 0.7 3 0.4 1.8 0.6 2.6 0.4 139 12 139 165 7.1 0.1 7.5 6.7 05/30/2006 06:10:00 1.2 0.4 2.3 0.4 1.5 0.4 2.6 0.4 1.7 0.3 2.6 1.1 137 12 144 165 7.1 0.2 7.3 6.7 05/30/2006 06:20:00 1.4 0.4 2.6 0.4 1.7 0.4 2.6 0.7 1.8 0.4 2.6 1.1 142 10 148 165 7.1 0.1 7.3 6.7 05/30/2006 06:30:00 1.3 0.4 2.3 0.4 1.6 0.4 2.3 0.7 1.7 0.4 2.6 0.7 127 15 129 165 7.1 0.1 7.5 6.7 05/30/2006 06:40:00 1.6 0.3 2.3 0.7 1.9 0.3 2.6 1.1 2.1 0.3 2.6 1.1 150 10 152 165 7.3 0.2 7.5 6.7 05/30/2006 06:50:00 1.3 0.5 2.3 0.4 1.4 0.4 2.3 0.4 1.7 0.4 2.3 0.7 153 19 148 165 7.3 0.2 7.5 7 05/30/2006 07:00:00 2 1 3.8 0.4 1.8 1.2 4.2 0.4 2 0.9 3.8 0.4 148 20 145 165 7.4 0.1 7.5 7 05/30/2006 07:10:00 2.3 0.5 3.4 1.1 2.4 0.5 3.4 1.1 2.4 0.5 3.4 1.1 128 17 114 165 7.4 0.1 7.8 7 05/30/2006 07:20:00 1.9 0.6 3.4 0.4 1.9 0.7 3.4 0.4 2.1 0.5 3.4 1.1 138 11 145 165 7.5 0 8 7.3 05/30/2006 07:30:00 2.4 0.5 3.8 1.1 2.4 0.6 3.8 1.1 2.4 0.5 3.8 1.5 135 9 137 165 7.6 0 8 7.3 05/30/2006 07:40:00 2.6 0.5 4.2 0.7 2.5 0.6 3.8 0.4 2.6 0.5 3.8 1.1 142 11 143 165 7.6 0 7.8 7.3 05/30/2006 07:50:00 2.7 0.4 3.8 1.9 2.6 0.4 3.8 1.5 2.8 0.4 4.2 1.9 142 11 147 165 7.6 0 7.8 7.3 05/30/2006 08:00:00 2.6 0.3 3.4 1.5 2.5 0.3 3.4 1.9 2.7 0.3 3.4 1.9 150 9 152 165 7.6 0.1 7.8 7.3 05/30/2006 08:10:00 2.1 0.5 3 1.1 2 0.5 3 0.7 2.3 0.4 3 1.5 154 15 149 165 7.5 0 7.8 7.3 05/30/2006 08:20:00 3.1 0.4 4.2 1.9 3 0.4 4.2 2.3 3.2 0.4 4.2 2.3 155 7 152 165 7.5 0 7.8 7.3 05/30/2006 08:30:00 2.8 0.5 4.2 1.5 2.8 0.6 3.8 1.1 2.9 0.6 4.2 1.5 141 12 156 165 7.6 0 7.8 7.3 05/30/2006 08:40:00 2.7 0.4 3.8 1.5 2.6 0.4 3.8 1.1 2.9 0.4 4.2 1.9 155 5 154 165 7.6 0 7.8 7.3 05/30/2006 08:50:00 2.9 0.4 3.8 1.9 2.8 0.5 3.8 1.5 3.1 0.4 4.2 2.3 158 8 162 165 7.5 0 7.8 7.3 05/30/2006 09:00:00 2.8 0.4 4.2 1.9 2.6 0.4 3.8 1.5 2.9 0.3 4.2 2.3 164 6 172 165 7.6 0 7.8 7.3 05/30/2006 09:10:00 3.1 0.3 3.8 2.3 2.9 0.3 3.8 1.9 3.2 0.3 4.2 2.3 170 9 176 165 7.5 0 7.8 7.3 05/30/2006 09:20:00 3.2 0.3 4.2 2.6 3.1 0.3 4.2 2.3 3.4 0.3 4.2 2.6 168 4 164 165 7.6 0 7.8 7 05/30/2006 09:30:00 2.7 0.3 3.4 1.5 2.6 0.3 3.4 1.5 2.9 0.3 3.4 2.3 168 5 163 165 7.5 0 7.8 7.3 05/30/2006 09:40:00 3 0.4 4.2 1.9 2.9 0.4 3.8 1.5 3.3 0.4 4.2 1.9 163 2 165 165 7.5 0.1 7.8 7 05/30/2006 09:50:00 3.4 0.3 4.2 2.6 3.2 0.3 4.2 2.3 3.5 0.3 4.2 2.6 163 4 176 165 7.4 0.1 7.8 7.3 05/30/2006 10:00:00 3.7 0.4 4.6 2.6 3.5 0.4 4.6 2.3 3.8 0.4 4.6 2.6 159 5 160 165 7.6 0.1 7.8 7.3 05/30/2006 10:10:00 3.6 0.4 4.6 2.6 3.5 0.4 4.6 2.3 3.8 0.4 4.6 2.6 157 4 162 165 7.5 0 7.8 7.3 05/30/2006 10:20:00 4 0.3 4.9 3.4 3.9 0.3 4.9 3 4.2 0.3 5.3 3.4 158 5 155 165 7.4 0.1 7.8 7.3 05/30/2006 10:30:00 4.9 0.6 6.1 3.8 4.8 0.6 6.1 3.8 5 0.6 6.5 3.8 151 5 150 165 7.4 0 7.8 7.3 05/30/2006 10:40:00 5.4 0.3 6.1 4.6 5.4 0.3 6.1 4.6 5.5 0.4 6.5 4.2 148 4 150 165 7.6 0 7.8 7.3 05/30/2006 10:50:00 4.8 0.4 5.7 3.8 4.8 0.4 5.7 3.8 5 0.5 6.1 3.4 147 3 145 165 7.6 0 7.8 7.3 05/30/2006 11:00:00 4.3 0.5 5.3 3 4.4 0.5 5.3 3 4.4 0.5 5.3 3 148 5 151 165 7.8 0.1 8 7.5 05/30/2006 11:10:00 5.1 0.4 6.1 4.2 5.2 0.4 6.1 4.2 5.2 0.5 6.5 3.8 145 4 145 165 7.9 0 8.3 7.5 05/30/2006 11:20:00 5.4 0.4 6.1 4.6 5.4 0.3 6.5 4.6 5.6 0.4 6.8 4.6 147 5 145 165 7.8 0 8 7.5 05/30/2006 11:30:00 5.5 0.4 6.5 4.6 5.4 0.4 6.1 4.6 5.6 0.4 6.8 4.6 148 4 148 165 7.8 0 8.3 7.5 05/30/2006 11:40:00 5.5 0.3 6.5 4.6 5.4 0.3 6.5 4.6 5.5 0.4 6.5 4.2 149 4 153 165 7.8 0 8 7.5 05/30/2006 11:50:00 5 0.5 6.1 3.8 5 0.4 6.1 3.8 5.1 0.5 6.1 4.2 148 6 139 165 7.8 0 8.3 7.5 05/30/2006 12:00:00 4.9 0.4 5.7 3.8 4.9 0.4 5.7 3.8 5 0.4 6.1 3.8 150 5 147 165 7.8 0 8 7.8 05/30/2006 12:10:00 5.2 0.3 6.1 4.2 5.2 0.3 6.1 4.2 5.3 0.3 6.1 4.2 149 5 146 165 7.8 0 8 7.5 05/30/2006 12:20:00 4.9 0.4 5.7 3.8 4.9 0.4 5.7 3.8 5.1 0.5 6.1 3.8 148 5 148 165 7.8 0 8 7.5 05/30/2006 12:30:00 4.9 0.5 6.1 3.8 4.9 0.4 6.1 3.8 5.1 0.5 6.1 3.8 148 5 154 165 7.8 0 8 7.3 05/30/2006 12:40:00 4.4 0.4 5.3 2.6 4.5 0.5 5.7 3 4.6 0.5 5.7 3 147 6 147 165 7.8 0 8.5 7.3 05/30/2006 12:50:00 3.4 0.6 4.9 2.3 3.5 0.6 4.9 2.3 3.6 0.6 4.9 2.3 141 10 138 165 7.8 0 8 7.3 05/30/2006 13:00:00 3.1 0.4 4.2 2.3 3.1 0.4 3.8 2.3 3.3 0.4 4.6 2.3 141 8 148 165 7.8 0.2 8 7.3 05/30/2006 13:10:00 3.1 0.4 4.6 2.3 3.1 0.4 4.6 2.3 3.3 0.4 4.6 2.6 141 7 130 165 7.8 0.2 8 7.5 05/30/2006 13:20:00 3.7 0.5 4.9 2.3 3.8 0.5 4.9 2.3 3.9 0.4 4.9 2.6 140 8 144 165 7.8 0.2 8 7.5 05/30/2006 13:30:00 4.1 0.5 5.7 3 4.1 0.5 5.3 2.6 4.2 0.4 5.3 3.4 144 7 145 165 7.8 0.2 8.5 7.5 05/30/2006 13:40:00 4.3 0.4 5.3 3 4.3 0.4 5.7 3.4 4.4 0.4 5.7 3 143 8 137 165 7.6 0.1 8.5 7.3 05/30/2006 13:50:00 4.3 0.4 5.3 3.4 4.3 0.4 5.3 3 4.4 0.5 5.7 3 141 7 136 165 7.6 0.2 8 7.3 05/30/2006 14:00:00 4 0.5 5.3 2.6 4 0.5 5.3 2.6 4 0.5 4.9 2.3 138 8 135 165 7.8 0.2 8 7.3 05/30/2006 14:10:00 4.3 0.6 6.1 3 4.3 0.6 5.7 2.6 4.2 0.6 5.7 2.6 143 8 149 165 7.9 0.1 8.3 7.5 05/30/2006 14:20:00 4.1 0.6 5.3 2.6 4.1 0.6 5.3 2.3 4 0.6 5.3 2.6 144 7 139 165 8 0.2 8.3 7.5 05/30/2006 14:30:00 3.8 0.5 5.3 2.6 3.8 0.5 5.3 2.6 3.7 0.4 5.3 2.6 146 8 147 165 8.1 0.2 8.5 7.5 05/30/2006 14:40:00 4.1 0.3 4.9 3 4 0.3 4.9 3 4.1 0.3 4.9 3 152 6 159 165 8.1 0.2 8.5 7.8 05/30/2006 14:50:00 3.9 0.4 5.3 2.6 3.8 0.4 4.9 2.6 4 0.4 5.3 3 157 8 162 165 8.4 0.2 9 7.8 05/30/2006 15:00:00 4.9 0.5 6.5 3.4 4.8 0.5 6.1 3.4 4.9 0.5 6.1 3.8 163 5 165 165 8.5 0.1 8.8 8 05/30/2006 15:10:00 5 0.6 7.2 3.8 4.9 0.6 6.8 3.8 5 0.6 7.2 3.8 157 10 176 165 8.8 0 9.3 8.5 05/30/2006 15:20:00 5.9 0.9 7.6 3.8 5.8 0.8 7.6 3.4 5.8 1 7.6 3.4 161 10 160 165 8.9 0.1 9.3 8.5 05/30/2006 15:30:00 8.3 0.8 9.5 5.7 8.1 0.7 9.5 5.7 8.4 0.8 9.9 6.1 166 16 157 165 8.9 0.1 9.3 8.5 05/30/2006 15:40:00 8.3 0.6 9.9 6.1 8 0.6 9.5 6.1 8.3 0.7 9.9 6.5 164 13 169 165 8.8 0 9 8.5 05/30/2006 15:50:00 6.9 0.8 8.8 4.6 6.7 0.7 8.8 4.6 6.9 0.8 8.8 4.9 163 14 165 165 8.8 0.1 9 8.5 05/30/2006 16:00:00 6 0.6 7.2 4.2 5.8 0.6 7.2 4.2 6 0.6 7.2 4.2 161 9 147 165 8.9 0.2 9.3 8.5 05/30/2006 16:10:00 5.9 0.6 7.2 4.6 5.8 0.5 7.2 4.2 6 0.5 7.6 4.9 162 7 165 165 9.3 0.2 9.6 8.8 05/30/2006 16:20:00 5.7 0.6 7.2 4.6 5.7 0.5 6.8 4.6 5.7 0.6 7.2 4.2 161 6 164 165 9.6 0.1 9.8 9 05/30/2006 16:30:00 5.6 0.5 7.2 4.2 5.5 0.5 6.8 3.8 5.8 0.4 6.8 4.6 161 6 170 165 9.6 0.1 9.8 9.3 05/30/2006 16:40:00 5.1 0.6 6.5 3.4 5.1 0.5 6.1 3.4 5.2 0.5 6.1 3.8 162 7 160 165 9.7 0 10.1 9.6 05/30/2006 16:50:00 5.8 0.5 7.2 4.2 5.7 0.5 6.8 4.2 5.9 0.5 7.2 4.6 158 15 160 165 10 0 10.3 9.6 05/30/2006 17:00:00 5.1 0.5 6.5 4.2 5.3 0.5 6.8 4.2 5.1 0.5 6.5 3.8 127 8 116 165 9.3 0.2 10.1 8.8 05/30/2006 17:10:00 5 0.4 6.1 4.2 5.1 0.4 6.8 4.2 4.9 0.4 6.5 3.8 122 4 119 165 9.2 0.2 9.6 8.5 05/30/2006 17:20:00 5.6 0.4 6.5 4.6 5.6 0.4 6.8 4.6 5.5 0.4 6.5 4.2 122 5 125 165 9.2 0.1 9.6 8.5 05/30/2006 17:30:00 5.6 0.4 6.8 4.6 5.6 0.4 6.8 4.6 5.5 0.4 6.8 3.8 128 6 128 165 9.1 0.1 9.3 8.5 05/30/2006 17:40:00 5.9 0.5 7.2 4.6 5.9 0.5 7.2 4.6 5.9 0.5 7.2 4.6 132 5 132 165 9 0.1 9.3 8.5 05/30/2006 17:50:00 5.8 0.6 7.6 4.2 5.8 0.6 7.6 3.8 5.6 0.6 7.6 4.2 131 6 130 165 9.1 0.1 9.6 8.8 05/30/2006 18:00:00 6.2 0.5 7.2 4.6 6.2 0.5 7.2 4.6 6.1 0.5 7.6 4.6 130 6 126 165 9.4 0.1 9.6 8.8 05/30/2006 18:10:00 6.2 0.7 7.6 3.8 6.2 0.7 8 4.2 6.2 0.7 7.6 4.6 135 10 134 165 9.7 0 9.8 9.3 05/30/2006 18:20:00 5.7 0.6 7.2 4.2 5.7 0.6 7.2 4.2 5.5 0.5 6.8 4.2 133 8 136 165 9.8 0 10.1 9.3 05/30/2006 18:30:00 5.6 0.7 7.2 3.8 5.6 0.7 7.2 3.8 5.6 0.7 7.2 3.8 134 9 142 165 9.8 0 10.1 9.6 05/30/2006 18:40:00 4.9 0.6 6.5 3.4 4.8 0.6 6.1 3.4 4.9 0.5 6.1 3 143 9 140 165 9.8 0.2 10.3 9.3 05/30/2006 18:50:00 4.7 0.6 6.5 2.6 4.6 0.6 6.1 2.6 4.7 0.6 6.5 2.6 140 12 162 165 10.1 0 10.6 9.8 05/30/2006 19:00:00 4.7 0.6 6.5 2.6 4.6 0.6 6.1 2.6 4.7 0.6 6.1 2.6 140 8 148 165 9.8 0 10.1 9.6 05/30/2006 19:10:00 4.4 0.5 6.1 2.6 4.3 0.6 5.7 2.6 4.5 0.6 6.1 2.6 145 11 154 165 9.6 0 9.8 9.6 05/30/2006 19:20:00 4.8 0.5 6.1 3.4 4.8 0.5 6.1 3.4 4.8 0.5 6.1 3.8 146 8 151 165 9.3 0 9.6 9 05/30/2006 19:30:00 4.5 0.6 6.5 2.6 4.5 0.6 6.1 2.6 4.7 0.6 6.5 3.4 147 10 164 165 9 0 9 9 05/30/2006 19:40:00 4.6 0.5 5.7 3.4 4.5 0.5 6.1 3.4 4.7 0.4 5.7 3.4 147 9 130 165 9.1 0.1 9.3 8.8 05/30/2006 19:50:00 4.2 0.4 5.3 3 4.1 0.4 5.3 2.6 4.3 0.4 5.7 3 146 9 136 165 8.6 0.1 9 8.5 05/30/2006 20:00:00 4 0.4 5.3 2.6 4 0.4 4.9 2.6 4.1 0.4 5.3 3 150 8 151 165 8.7 0 9 8.5 05/30/2006 20:10:00 4.2 0.5 5.7 3 4.2 0.5 5.7 2.6 4.3 0.5 6.1 3 151 8 154 165 8.7 0 9 8.5 05/30/2006 20:20:00 5.3 0.8 7.2 3 5.2 0.8 7.2 2.6 5.3 0.8 6.8 2.6 149 8 155 165 8.7 0.1 9 8.5 05/30/2006 20:30:00 5.5 0.6 6.8 3.8 5.5 0.6 6.8 3.8 5.6 0.6 6.8 4.2 149 7 156 165 8.7 0.1 9 8.3 05/30/2006 20:40:00 5.5 0.6 7.6 4.2 5.5 0.6 7.6 4.2 5.5 0.6 7.2 3.8 144 10 139 165 8.6 0.1 9 8.3 05/30/2006 20:50:00 5.3 0.5 6.8 4.2 5.3 0.5 6.8 4.2 5.3 0.5 6.8 3.8 142 9 139 165 8.5 0.2 9 8 05/30/2006 21:00:00 4.9 0.6 6.5 3.4 4.9 0.6 6.5 3.8 4.9 0.6 6.5 3.8 137 8 132 165 8.3 0.2 8.5 7.8 05/30/2006 21:10:00 4.3 0.5 5.7 3 4.4 0.5 5.7 3 4.4 0.5 5.7 2.6 133 12 154 165 8.3 0 8.5 8.3 05/30/2006 21:20:00 3.9 0.5 5.3 2.6 3.9 0.4 4.9 2.6 3.9 0.4 4.9 3 154 7 164 165 8.4 0 8.5 8.3 05/30/2006 21:30:00 3.9 0.6 5.3 2.6 3.9 0.6 4.9 3 4 0.5 4.9 3 155 6 156 165 8.5 0 9 8.3 05/30/2006 21:40:00 3.8 0.4 4.9 2.6 3.8 0.4 4.6 2.6 3.9 0.4 4.9 3 158 6 162 165 8.4 0 8.5 8.3 05/30/2006 21:50:00 3.4 0.4 4.2 2.3 3.3 0.3 4.2 2.3 3.4 0.3 4.6 2.6 161 5 158 165 8.3 0 8.5 8.3 05/30/2006 22:00:00 3.5 0.4 4.2 2.6 3.4 0.3 4.2 2.6 3.6 0.4 4.6 2.6 168 5 167 165 8.5 0 8.5 8.3 05/30/2006 22:10:00 3.3 0.3 3.8 2.6 3.2 0.3 3.8 2.3 3.2 0.3 3.8 2.6 162 4 165 165 8.5 0 8.8 8.3 05/30/2006 22:20:00 3 0.4 4.2 2.3 3 0.4 3.8 2.3 3.1 0.4 4.2 2.3 159 3 162 165 8.4 0 8.5 8.3 05/30/2006 22:30:00 2 0.2 2.6 1.5 2.1 0.2 2.6 1.5 2.2 0.2 2.6 1.5 157 6 164 165 8.5 0 8.5 8.3 05/30/2006 22:40:00 2 0.3 2.6 1.5 2 0.2 2.6 1.5 1.9 0.2 2.3 1.5 161 4 162 165 8.5 0 9 8.3 05/30/2006 22:50:00 1.6 0.2 1.9 1.1 1.6 0.2 1.9 1.1 1.7 0.3 2.3 1.1 162 3 165 165 8.5 0 8.5 8.3 05/30/2006 23:00:00 1.5 0.2 2.3 1.1 1.6 0.2 2.3 1.1 1.7 0.2 2.3 1.1 167 5 164 165 8.5 0 8.8 8.5 05/30/2006 23:10:00 2 0.5 3.4 1.1 2.1 0.5 3.4 1.1 2.1 0.4 3 1.1 186 11 197 165 8.8 0 9 8.5 05/30/2006 23:20:00 1.7 0.2 2.3 1.1 1.7 0.2 2.3 1.1 1.9 0.2 2.3 1.1 171 5 172 165 8.6 0.1 8.8 8.3 05/30/2006 23:30:00 1.9 0.2 2.3 1.5 1.9 0.2 2.3 1.5 2.1 0.2 2.6 1.9 161 8 165 165 8.4 0.1 8.8 8 05/30/2006 23:40:00 2.2 0.2 2.6 1.9 2.2 0.2 2.6 1.9 2.4 0.2 3 1.9 162 4 160 165 8.3 0 8.5 8 05/30/2006 23:50:00 2 0.2 2.6 1.5 2 0.2 2.6 1.5 2.1 0.2 2.6 1.5 179 3 177 165 8.5 0.1 8.8 8 05/31/2006 00:00:00 1.7 0.2 2.3 1.1 1.7 0.2 2.3 1.1 1.9 0.2 2.3 1.1 160 6 154 165 8.4 0.1 9 8 05/31/2006 00:10:00 1.9 0.2 2.3 1.1 2 0.2 2.3 1.5 2.1 0.2 2.6 1.5 151 7 163 165 8.3 0.1 8.5 8 05/31/2006 00:20:00 1.9 0.4 3 1.1 2 0.4 3 1.1 2.2 0.4 3 1.5 147 11 136 165 8.2 0 8.5 7.8 05/31/2006 00:30:00 2.5 0.4 3.4 1.9 2.5 0.4 3.4 1.9 2.5 0.3 3 1.5 162 4 164 165 8.2 0 8.5 7.8 05/31/2006 00:40:00 2.6 0.3 3.4 1.5 2.6 0.2 3 1.9 2.7 0.3 3.4 1.9 161 4 155 165 8.3 0.2 8.5 7.8 05/31/2006 00:50:00 2.6 0.3 3.4 1.5 2.7 0.3 3.4 1.9 2.9 0.3 3.4 2.3 150 7 149 165 8.3 0 8.8 7.8 05/31/2006 01:00:00 2.6 0.3 3.4 1.9 2.6 0.3 3.4 1.9 2.8 0.3 3.4 2.3 150 6 154 165 8.2 0 8.5 7.8 05/31/2006 01:10:00 2.5 0.4 3.4 1.5 2.6 0.3 3.4 1.5 2.7 0.3 3.4 1.9 156 8 162 165 8.1 0 8.5 7.5 05/31/2006 01:20:00 2.2 0.3 3 1.1 2.2 0.3 3 1.5 2.3 0.3 3 1.5 156 9 157 165 8 0.1 8.3 7.5 05/31/2006 01:30:00 2.7 0.4 3.4 1.5 2.7 0.4 3.4 1.5 2.8 0.4 3.4 1.9 164 8 177 165 8.3 0.1 8.5 7.8 05/31/2006 01:40:00 3.2 0.3 4.2 2.3 3.2 0.3 4.2 2.3 3.2 0.3 4.2 2.3 156 8 164 165 8.3 0 8.5 7.8 05/31/2006 01:50:00 2.8 0.4 3.8 1.9 2.9 0.4 3.8 1.9 2.8 0.3 3.8 1.9 164 9 165 165 8.3 0 8.5 7.8 05/31/2006 02:00:00 2.4 0.5 3.4 1.1 2.4 0.4 3.4 1.1 2.5 0.4 3.4 1.9 171 7 163 165 8.2 0 8.5 7.8 05/31/2006 02:10:00 2.1 0.4 3.4 1.1 2.1 0.4 3.4 1.1 2.1 0.4 3.8 1.1 174 8 183 165 8.2 0 8.5 7.8 05/31/2006 02:20:00 1.9 0.6 3 0.4 1.9 0.6 3 0.4 1.7 0.5 2.6 0.4 178 11 181 165 8.2 0 8.5 7.8 05/31/2006 02:30:00 2.3 0.6 3.4 0.7 2.3 0.6 3.8 0.4 2.2 0.5 3.4 1.1 191 16 179 165 8.3 0.1 8.5 7.8 05/31/2006 02:40:00 3.1 0.6 4.2 1.5 3.2 0.6 4.6 1.9 2.7 0.7 4.2 1.5 204 9 218 165 8.5 0 8.5 8 05/31/2006 02:50:00 3.6 0.6 5.3 1.9 3.7 0.6 5.7 2.3 3.5 0.6 5.7 1.9 216 4 216 165 8.5 0.1 8.5 8 05/31/2006 03:00:00 3.9 0.5 5.3 2.6 4 0.5 5.3 2.3 3.8 0.6 4.9 2.3 212 7 207 165 8.5 0.1 8.5 8 05/31/2006 03:10:00 4.2 0.3 5.3 3 4.4 0.4 5.3 3 4.2 0.4 4.9 2.3 213 8 210 165 8.5 0.1 8.5 8 05/31/2006 03:20:00 4.4 0.6 5.7 2.6 4.6 0.6 5.7 3 4.5 0.7 5.7 3 204 5 205 165 8.4 0.1 8.5 8 05/31/2006 03:30:00 3.2 0.5 4.2 1.9 3.3 0.5 4.6 1.9 3.2 0.5 4.6 1.5 215 6 223 165 8.3 0 8.5 8 05/31/2006 03:40:00 3.1 0.6 4.6 1.9 3.2 0.6 4.6 1.9 3.2 0.5 4.6 1.5 206 8 193 165 8.3 0 8.5 7.8 05/31/2006 03:50:00 3.9 0.4 4.6 2.6 3.9 0.4 4.9 3 3.7 0.5 4.9 2.6 199 5 199 165 8.3 0 8.5 7.8 05/31/2006 04:00:00 3.8 0.5 5.3 2.3 3.9 0.5 5.3 2.3 3.6 0.5 4.6 1.9 206 6 210 165 8.3 0.1 8.5 7.8 05/31/2006 04:10:00 4 0.5 5.7 2.6 4.1 0.5 5.7 3 3.8 0.6 5.3 2.6 208 6 206 165 8.3 0.2 8.5 7.8 05/31/2006 04:20:00 3.8 0.6 4.9 2.6 4 0.6 5.3 2.6 3.8 0.6 5.3 2.3 209 4 212 165 8.3 0 8.5 7.8 05/31/2006 04:30:00 3.3 0.4 4.2 2.3 3.4 0.4 4.2 2.3 3.2 0.5 4.2 1.9 207 6 215 165 8.2 0 8.5 7.8 05/31/2006 04:40:00 3 0.5 4.2 1.5 3.1 0.5 4.2 1.5 2.9 0.5 4.2 1.5 210 8 207 165 8.2 0 8.5 7.8 05/31/2006 04:50:00 2.8 0.4 3.8 1.9 2.9 0.4 3.8 1.9 2.9 0.4 3.8 1.9 211 8 217 165 8.2 0 8.5 7.5 05/31/2006 05:00:00 3.1 0.3 3.8 2.6 3.2 0.3 3.8 2.6 3.2 0.3 3.8 2.3 201 3 205 165 8.2 0 8.5 7.8 05/31/2006 05:10:00 3.5 0.5 4.9 2.3 3.6 0.5 4.6 2.6 3.3 0.5 4.9 2.3 203 4 207 165 8.2 0.1 8.5 7.8 05/31/2006 05:20:00 4.1 0.5 5.3 2.6 4.1 0.5 5.3 2.6 4.1 0.5 5.3 3 199 6 204 165 8.3 0.2 8.5 7.8 05/31/2006 05:30:00 3.3 0.5 4.2 1.9 3.3 0.5 4.2 1.9 3.3 0.5 4.6 2.3 199 8 190 165 8.3 0.1 8.5 7.8 05/31/2006 05:40:00 3.5 0.5 4.9 2.3 3.6 0.5 4.9 2.6 3.5 0.5 4.6 1.9 205 4 203 165 8.4 0.2 8.5 7.8 05/31/2006 05:50:00 3.5 0.4 4.9 2.6 3.6 0.4 4.9 2.3 3.4 0.5 4.9 1.9 206 7 197 165 8.4 0.2 8.5 8 05/31/2006 06:00:00 3.7 0.4 4.6 2.3 3.8 0.4 4.6 2.3 3.6 0.5 4.9 2.3 211 5 217 165 8.4 0.2 8.8 8 05/31/2006 06:10:00 4.1 0.4 4.6 3 4.3 0.4 4.9 3 4 0.4 4.9 2.6 216 4 211 165 8.5 0 8.8 8.3 05/31/2006 06:20:00 3.9 0.6 4.9 1.9 4.1 0.6 5.3 1.9 4 0.6 5.3 2.6 224 8 227 165 8.7 0 9 8.3 05/31/2006 06:30:00 3.2 0.5 4.2 1.5 3.4 0.5 4.6 1.5 3.2 0.5 4.2 1.9 217 10 238 165 8.8 0 9 8.5 05/31/2006 06:40:00 3.2 0.5 4.6 1.9 3.3 0.5 4.9 2.3 3.2 0.5 4.9 2.3 202 11 210 165 8.8 0 9 8.5 05/31/2006 06:50:00 2.6 0.4 3.8 1.5 2.6 0.4 3.8 1.5 2.8 0.4 4.2 1.9 192 8 176 165 8.7 0 9 8.5 05/31/2006 07:00:00 3.9 0.6 5.3 2.3 3.9 0.6 5.3 2.3 4 0.7 5.7 2.3 200 7 203 165 8.8 0 9 8.5 05/31/2006 07:10:00 2.8 0.5 4.2 1.1 2.8 0.5 4.2 1.1 2.9 0.5 4.2 1.1 200 13 203 165 8.9 0 9 8.5 05/31/2006 07:20:00 2.9 0.5 4.2 1.5 2.9 0.5 4.2 1.5 3.1 0.4 4.2 1.9 185 10 199 165 8.9 0 9 8.8 05/31/2006 07:30:00 5.4 0.9 7.2 2.6 5.3 0.9 6.8 2.6 5.6 0.9 7.2 3.4 182 8 189 165 9.1 0 9.3 8.8 05/31/2006 07:40:00 4.1 0.5 5.7 2.6 4.2 0.5 5.3 2.6 4.3 0.5 5.7 2.6 201 7 198 165 9.4 0 9.8 9 05/31/2006 07:50:00 3.6 0.6 4.9 1.9 3.5 0.5 4.9 1.9 3.8 0.6 5.7 2.3 192 11 182 165 9.6 0.1 9.8 9 05/31/2006 08:00:00 3.9 0.7 5.7 2.3 3.9 0.7 5.7 2.3 4.2 0.7 6.5 2.6 180 12 166 165 9.6 0.2 9.8 9 05/31/2006 08:10:00 4.5 0.6 6.5 2.6 4.5 0.7 6.1 2.6 4.7 0.7 6.8 2.6 192 15 179 165 9.8 0.1 10.1 9 05/31/2006 08:20:00 4.1 0.8 5.7 1.9 4.2 0.8 6.1 1.9 4.3 0.7 6.1 2.6 202 16 223 165 9.8 0 10.3 9.3 05/31/2006 08:30:00 4.8 0.7 6.5 3.4 4.9 0.7 6.5 3.4 4.8 0.8 6.5 3.4 215 9 224 165 9.9 0.1 10.3 9.6 05/31/2006 08:40:00 3.6 0.6 5.7 2.6 3.7 0.6 6.1 2.6 3.7 0.6 6.8 2.6 219 10 215 165 10.1 0.1 10.6 9.6 05/31/2006 08:50:00 3.8 0.8 6.1 1.9 4 0.7 6.1 2.3 3.8 0.7 6.1 1.9 240 19 241 165 10.5 0.1 11.1 10.3 05/31/2006 09:00:00 3.8 1.3 7.2 1.1 4 1.2 7.6 1.5 4 1.4 7.6 1.5 203 23 169 165 11.3 0.1 11.7 10.9 05/31/2006 09:10:00 5.4 0.9 8 3 5.5 0.9 7.6 3 5.6 0.9 7.6 3.4 206 13 189 165 10.8 0.1 11.4 10.9 05/31/2006 09:20:00 3.9 1.3 6.5 1.1 4 1.3 6.5 0.7 4 1.3 6.5 1.1 204 19 201 165 10.7 0 10.9 10.6 05/31/2006 09:30:00 3.4 1 5.7 0.7 3.5 1 6.1 0.7 3.6 0.9 5.7 1.5 199 19 225 165 10.9 0 11.1 10.6 05/31/2006 09:40:00 4 0.7 6.1 1.9 4.1 0.7 5.7 2.3 4.2 0.7 5.7 2.6 191 17 207 165 10.7 0 11.1 10.9 05/31/2006 09:50:00 4.6 1 6.5 1.9 4.6 1 6.5 1.9 4.7 1 7.2 2.6 174 12 165 165 10.5 0.1 10.9 10.3 05/31/2006 10:00:00 4.2 0.5 5.3 1.9 4.2 0.5 4.9 2.6 4.2 0.4 5.3 3 146 8 159 165 9.8 0.2 10.3 9.6 05/31/2006 10:10:00 3.3 0.5 4.6 1.9 3.2 0.5 4.6 1.9 3.3 0.5 4.6 2.3 148 11 165 165 10 0.1 10.3 9.6 05/31/2006 10:20:00 3.1 0.6 4.9 1.5 3 0.6 4.6 1.5 3.1 0.5 4.6 1.5 135 11 155 165 10.1 0 10.3 9.8 05/31/2006 10:30:00 3.6 0.4 4.6 2.3 3.6 0.5 4.6 2.3 3.6 0.5 4.9 2.3 136 7 129 165 10.5 0.2 10.9 10.1 05/31/2006 10:40:00 3.9 0.4 5.3 2.6 3.9 0.5 5.3 2.6 4 0.4 5.7 3 140 8 164 165 10.9 0.2 11.4 10.6 05/31/2006 10:50:00 3.7 0.4 4.9 2.6 3.7 0.4 4.9 2.6 3.8 0.5 4.9 2.6 139 6 147 165 10.7 0.2 11.4 9.8 05/31/2006 11:00:00 3 0.5 4.2 1.9 3 0.5 4.6 1.9 3 0.5 4.2 2.3 129 10 143 165 10.3 0 10.6 9.8 05/31/2006 11:10:00 2.9 0.5 3.8 1.9 2.9 0.5 4.2 1.9 2.9 0.4 3.8 1.9 132 9 140 165 10.6 0.1 10.9 9.8 05/31/2006 11:20:00 2.4 0.5 3.4 0.7 2.5 0.5 3.4 1.1 2.5 0.5 3.4 1.1 129 11 130 165 10.3 0 10.9 9.8 05/31/2006 11:30:00 1.8 0.5 3.4 0.7 1.8 0.5 3.4 0.7 1.9 0.5 3.4 0.7 138 9 125 165 10.7 0.1 10.9 10.3 05/31/2006 11:40:00 2.1 0.4 3.4 1.1 2.1 0.4 3.4 1.1 2.2 0.4 3.4 1.1 136 13 148 165 10.8 0 11.1 10.3 05/31/2006 11:50:00 1.3 0.5 3 0.4 1.3 0.6 3 0.4 1.4 0.5 3 0.4 142 15 143 165 11.1 0 11.4 10.9 05/31/2006 12:00:00 1.6 0.5 2.6 0.4 1.6 0.5 2.6 0.4 1.6 0.5 2.6 0.4 134 13 145 165 11.3 0 11.7 10.9 05/31/2006 12:10:00 1.9 0.7 3.4 0.4 2 0.7 3.8 0.4 2 0.5 3.4 0.7 142 16 145 165 11.4 0.1 11.7 10.9 05/31/2006 12:20:00 1.3 0.6 3 0.4 1.3 0.6 2.6 0.4 1.4 0.5 3 0.4 139 24 140 165 11.7 0.2 11.9 11.4 05/31/2006 12:30:00 1.7 0.7 3 0.4 1.8 0.7 3 0.4 1.8 0.6 3 0.4 126 22 164 165 11.7 0 11.9 11.7 05/31/2006 12:40:00 1.6 0.8 3.4 0.4 1.7 0.8 3.8 0.4 1.7 0.8 3.4 0.4 134 28 116 165 11.7 0.1 11.9 11.4 05/31/2006 12:50:00 1.8 0.9 4.6 0.4 1.8 0.8 4.2 0.4 1.7 1 4.2 0.4 51 82 62 165 11.7 0.1 11.9 11.4 05/31/2006 13:00:00 1.8 0.4 3 0.7 1.8 0.4 3 0.7 2.1 0.4 3 1.1 34 9 15 165 10.9 0.1 11.4 10.6 05/31/2006 13:10:00 1.8 0.6 3.8 0.4 1.8 0.6 3.4 0.4 1.8 0.7 3.8 0.4 44 58 323 165 10.8 0.2 11.4 10.3 05/31/2006 13:20:00 1.3 0.9 3.4 0.4 1.3 0.9 3.4 0.4 1.2 0.9 3.4 0.4 47 82 41 165 11.5 0.2 11.9 10.9 05/31/2006 13:30:00 2.6 0.4 3.8 1.5 2.5 0.4 3.4 1.1 2.5 0.4 3.8 1.5 32 15 15 165 11.1 0.2 11.9 10.6 05/31/2006 13:40:00 2.7 0.5 3.8 1.5 2.6 0.6 3.8 1.1 2.6 0.6 4.2 1.1 24 15 36 165 10.9 0 11.1 10.9 05/31/2006 13:50:00 2.6 0.7 4.2 0.4 2.2 0.7 3.8 0.4 2.8 0.8 4.6 0.4 14 14 17 165 11.1 0 11.4 10.9 05/31/2006 14:00:00 2.1 0.7 3.8 0.4 1.9 0.7 3.8 0.4 1.9 0.7 3.4 0.4 18 26 23 165 11.2 0 11.4 10.9 05/31/2006 14:10:00 2.1 0.6 3.4 0.4 1.9 0.6 3.4 0.4 1.7 0.6 3 0.4 23 33 28 165 11.3 0.1 11.7 10.9 05/31/2006 14:20:00 1.5 0.7 3.4 0.4 1.3 0.7 3 0.4 1.3 0.7 3 0.4 11 33 108 165 11.5 0.1 11.7 10.9 05/31/2006 14:30:00 2 0.5 3.8 0.7 1.8 0.5 3 0.4 1.8 0.5 3 0.7 9 16 358 165 11.1 0.2 11.7 10.6 05/31/2006 14:40:00 2.3 0.6 3.8 1.1 1.9 0.6 3.4 0.7 2.2 0.6 3.8 0.7 9 13 2 165 11.1 0.1 11.4 10.6 05/31/2006 14:50:00 1.6 0.6 3 0.4 1.4 0.7 3 0.4 1.5 0.7 3 0.4 55 43 3 165 11 0 11.4 10.9 05/31/2006 15:00:00 1.8 0.9 3.4 0.4 1.5 0.7 3.4 0.4 1.8 0.9 3.4 0.4 13 58 6 165 11.3 0.2 11.7 10.9 05/31/2006 15:10:00 2.1 0.6 3.4 0.7 2.1 0.6 3.4 0.7 2.3 0.5 3.4 0.7 37 12 36 165 10.9 0.2 11.4 10.6 05/31/2006 15:20:00 2 0.6 3.4 0.4 1.7 0.5 3.4 0.4 2 0.5 3 0.4 10 19 22 165 11.1 0.2 11.7 10.6 05/31/2006 15:30:00 2.3 0.4 3.4 1.5 1.9 0.5 3 0.7 2.4 0.4 3.4 1.5 9 12 8 165 11.3 0.1 11.7 10.9 05/31/2006 15:40:00 1.4 0.5 3.4 0.4 1.4 0.5 2.6 0.4 1.3 0.5 2.6 0.4 38 41 300 165 11.1 0 11.4 10.6 05/31/2006 15:50:00 1.3 0.7 3 0.4 1.1 0.6 2.6 0.4 1.2 0.7 3 0.4 28 51 350 165 11.3 0 11.7 10.9 05/31/2006 16:00:00 2 0.4 3 1.1 1.5 0.5 2.6 0.7 2 0.3 3 1.1 359 10 6 165 11.3 0.1 11.7 10.9 05/31/2006 16:10:00 1.4 0.3 2.3 0.7 0.9 0.4 1.9 0.4 1.6 0.3 2.3 0.7 2 8 359 165 11.3 0 11.4 10.9 05/31/2006 16:20:00 1.1 0.6 2.3 0.4 0.8 0.5 2.3 0.4 1.2 0.5 2.3 0.4 13 24 341 165 11.1 0.1 11.4 10.9 05/31/2006 16:30:00 0.8 0.5 2.3 0.4 0.7 0.5 2.6 0.4 0.8 0.5 2.3 0.4 29 64 109 165 11.3 0.1 11.7 10.9 05/31/2006 16:40:00 1.1 0.5 2.3 0.4 1.1 0.5 2.3 0.4 0.9 0.5 2.3 0.4 135 17 138 165 11.6 0 11.9 11.1 05/31/2006 16:50:00 0.7 0.4 1.9 0.4 0.7 0.4 1.9 0.4 0.7 0.4 1.9 0.4 45 47 8 165 11.4 0.1 11.9 10.9 05/31/2006 17:00:00 0.5 0.4 1.9 0.4 0.6 0.4 1.9 0.4 0.4 0.2 1.5 0.4 57 86 133 165 11.6 0.1 11.9 11.1 05/31/2006 17:10:00 0.4 0.1 1.1 0.4 0.4 0.2 1.1 0.4 0.4 0.2 1.5 0.4 38 58 20 165 11.7 0 11.9 11.4 05/31/2006 17:20:00 1 0.5 2.3 0.4 0.9 0.5 2.3 0.4 1.1 0.5 3 0.4 359 38 1 165 11.2 0.2 11.7 10.6 05/31/2006 17:30:00 0.5 0.3 1.5 0.4 0.6 0.3 1.5 0.4 0.7 0.4 1.9 0.4 4 35 23 165 11.3 0.1 11.7 10.9 05/31/2006 17:40:00 0.5 0.3 1.5 0.4 0.5 0.3 1.5 0.4 0.6 0.3 1.5 0.4 304 29 310 165 11.3 0 11.7 11.1 05/31/2006 17:50:00 0.7 0.4 1.9 0.4 0.6 0.4 1.9 0.4 0.7 0.4 1.9 0.4 343 3 344 165 11.2 0.1 11.7 10.9 05/31/2006 18:00:00 0.4 0.2 1.1 0.4 0.4 0.1 1.1 0.4 0.6 0.4 1.9 0.4 350 5 344 165 11.1 0.2 11.7 10.6 05/31/2006 18:10:00 0.4 0 0.7 0.4 0.4 0 0.4 0.4 0.4 0.2 1.1 0.4 355 0 355 165 10.9 0 11.4 10.6 05/31/2006 18:20:00 0.4 0.1 0.7 0.4 0.4 0.1 0.7 0.4 0.4 0.1 1.1 0.4 355 0 355 165 11.1 0 11.4 11.1 05/31/2006 18:30:00 0.4 0.1 1.1 0.4 0.4 0.2 1.1 0.4 0.4 0.2 1.1 0.4 356 4 14 165 11.1 0 11.4 10.9 05/31/2006 18:40:00 0.5 0.4 1.9 0.4 0.6 0.4 1.9 0.4 0.7 0.4 1.9 0.4 48 18 58 165 10.9 0 11.1 10.9 05/31/2006 18:50:00 1.1 0.6 2.3 0.4 1.2 0.6 2.3 0.4 1.4 0.5 2.3 0.4 114 8 108 165 10.9 0 11.4 10.9 05/31/2006 19:00:00 1.3 0.4 2.3 0.4 1.4 0.4 2.3 0.4 1.6 0.3 2.3 0.7 129 7 135 165 10.8 0 11.1 10.9 05/31/2006 19:10:00 1.8 0.3 2.6 1.1 1.9 0.3 2.6 1.1 1.9 0.2 2.6 1.5 134 4 129 165 10.7 0 11.1 10.9 05/31/2006 19:20:00 2.3 0.3 3 1.5 2.4 0.3 3 1.5 2.3 0.3 3 1.5 126 5 126 165 10.7 0 10.9 10.6 05/31/2006 19:30:00 2.4 0.3 3 1.9 2.5 0.2 3 1.9 2.4 0.2 3 1.5 126 5 121 165 10.4 0 10.6 10.3 05/31/2006 19:40:00 2.1 0.4 3 1.1 2.2 0.4 3 1.1 2.3 0.3 3 1.5 144 8 135 165 10.2 0 10.6 10.3 05/31/2006 19:50:00 1 0.6 2.3 0.4 1.1 0.7 2.3 0.4 1.3 0.7 2.6 0.4 146 13 126 165 10.1 0.1 10.3 9.6 05/31/2006 20:00:00 0.4 0.2 1.1 0.4 0.5 0.2 1.5 0.4 0.6 0.3 1.5 0.4 8 86 317 165 10.1 0 10.3 9.6 05/31/2006 20:10:00 0.4 0 0.4 0.4 0.4 0 0.7 0.4 0.5 0.2 1.1 0.4 349 14 165 165 10 0 10.3 9.8 05/31/2006 20:20:00 1.2 0.4 1.9 0.4 1.2 0.4 1.9 0.4 1.4 0.3 2.3 0.4 339 1 342 165 9.9 0 10.1 9.6 05/31/2006 20:30:00 1.3 0.4 2.3 0.4 1.4 0.4 2.3 0.4 1.5 0.3 2.3 0.7 327 9 320 165 9.6 0 9.8 9.3 05/31/2006 20:40:00 0.5 0.3 1.5 0.4 0.5 0.3 1.5 0.4 0.8 0.4 1.9 0.4 5 16 321 165 9.6 0 9.6 9.3 05/31/2006 20:50:00 1.2 0.3 1.9 0.4 1.3 0.3 1.9 0.4 1.4 0.2 1.9 1.1 324 1 325 165 9.4 0 9.6 9 05/31/2006 21:00:00 1.2 0.3 1.9 0.4 1.3 0.3 1.9 0.7 1.5 0.3 2.3 1.1 327 4 333 165 9.2 0.1 9.6 8.8 05/31/2006 21:10:00 0.4 0.2 1.5 0.4 0.4 0.2 1.5 0.4 0.6 0.3 1.5 0.4 319 1 319 165 9 0.1 9.3 8.8 05/31/2006 21:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0.1 0.7 0.4 319 0 165 165 9 0.1 9.3 8.5 05/31/2006 21:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.6 0.3 1.5 0.4 315 3 165 165 9 0.1 9.3 8.5 05/31/2006 21:40:00 1.4 0.6 2.3 0.4 1.5 0.6 2.6 0.4 1.6 0.5 2.6 0.4 313 4 316 165 8.9 0.2 9 8.5 05/31/2006 21:50:00 1.5 0.4 2.6 0.7 1.7 0.4 2.6 1.1 1.2 0.3 1.9 0.4 297 2 301 165 8.7 0.1 9.3 8.5 05/31/2006 22:00:00 2 0.4 3 1.1 2.2 0.4 3 1.5 2 0.4 3 1.1 292 3 289 165 8.7 0 9 8.5 05/31/2006 22:10:00 2.3 0.2 2.6 1.9 2.4 0.2 3 1.9 2.1 0.3 3 1.5 305 6 291 165 8.7 0.1 9 8.3 05/31/2006 22:20:00 2 0.3 2.6 1.1 2.2 0.3 3 1.5 1.6 0.4 2.6 0.7 301 4 308 165 8.7 0 9 8.5 05/31/2006 22:30:00 1.7 0.3 2.3 1.1 2 0.3 2.6 1.5 1.6 0.4 2.3 0.7 306 5 306 165 8.7 0 9 8.3 05/31/2006 22:40:00 1.7 0.5 3 0.4 2 0.4 3 0.7 1.6 0.4 2.6 0.7 303 5 304 165 8.8 0 9 8.3 05/31/2006 22:50:00 2 0.5 3 1.1 2.2 0.4 3.4 1.5 2.1 0.4 3 1.5 312 6 306 165 8.7 0 9 8.5 05/31/2006 23:00:00 1 0.6 2.6 0.4 1.1 0.7 2.6 0.4 1.3 0.6 2.6 0.4 331 9 329 165 8.7 0 8.8 8.5 05/31/2006 23:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.5 0.2 1.1 0.4 341 0 165 165 8.7 0 8.8 8.5 05/31/2006 23:20:00 0.4 0 0.4 0.4 0.4 0 0.7 0.4 0.6 0.2 1.1 0.4 341 0 165 165 8.7 0 8.8 8.5 05/31/2006 23:30:00 0.4 0.2 1.1 0.4 0.5 0.3 1.5 0.4 0.8 0.4 1.5 0.4 341 0 341 165 8.7 0 8.8 8.5 05/31/2006 23:40:00 0.6 0.3 1.5 0.4 0.5 0.3 1.5 0.4 1.1 0.3 1.5 0.7 341 0 341 165 8.7 0 9 8.5 05/31/2006 23:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.7 0.2 1.1 0.4 341 0 165 165 8.7 0 9 8.5 06/01/2006 00:00:00 1.1 0.5 2.3 0.4 1.3 0.6 2.3 0.4 1.3 0.3 1.9 0.7 318 15 311 165 8.7 0 9 8.5 06/01/2006 00:10:00 1.1 0.6 2.3 0.4 1.3 0.6 2.3 0.4 1.2 0.5 2.3 0.4 306 4 304 165 8.6 0 8.8 8.5 06/01/2006 00:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0.1 0.7 0.4 298 0 165 165 8.7 0 8.8 8.5 06/01/2006 00:30:00 0.5 0.2 1.1 0.4 0.5 0.3 1.1 0.4 0.6 0.4 1.5 0.4 198 66 165 165 8.7 0 9 8.5 06/01/2006 00:40:00 0.4 0.1 1.1 0.4 0.5 0.2 0.7 0.4 0.5 0.3 1.1 0.4 142 0 142 165 8.7 0 9 8.5 06/01/2006 00:50:00 0.4 0.2 1.1 0.4 0.4 0.2 1.1 0.4 0.9 0.2 1.5 0.4 142 1 142 165 8.8 0 9 8.5 06/01/2006 01:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.5 0.2 1.1 0.4 143 0 165 165 8.7 0.1 9 8.3 06/01/2006 01:10:00 0.4 0 0.7 0.4 0.4 0 0.4 0.4 0.4 0.2 1.5 0.4 110 45 1 165 8.3 0.2 9 8 06/01/2006 01:20:00 0.6 0.2 1.1 0.4 0.7 0.3 1.5 0.4 1.1 0.2 1.5 0.7 341 9 345 165 8.1 0.2 8.5 7.5 06/01/2006 01:30:00 0.4 0.2 1.1 0.4 0.5 0.2 1.1 0.4 1 0.2 1.5 0.4 327 0 327 165 8 0 8.5 7.5 06/01/2006 01:40:00 1.1 0.3 1.5 0.4 1.4 0.3 1.9 0.4 1.2 0.3 1.9 0.4 304 11 302 165 8.3 0 8.5 7.8 06/01/2006 01:50:00 2 0.3 2.6 1.1 2.2 0.3 2.6 1.5 1.9 0.3 2.6 1.1 301 8 293 165 8.5 0.1 8.5 7.8 06/01/2006 02:00:00 2.3 0.4 3 1.1 2.5 0.4 3.4 1.5 2.2 0.3 3 1.5 303 10 310 165 8.2 0 8.5 7.8 06/01/2006 02:10:00 1.4 0.3 2.3 0.7 1.6 0.2 2.3 1.1 1.4 0.4 2.6 0.7 296 7 284 165 8.3 0 8.5 7.8 06/01/2006 02:20:00 1 0.4 1.9 0.4 1 0.5 1.9 0.4 1 0.3 1.9 0.4 298 3 302 165 8.3 0.1 8.5 7.8 06/01/2006 02:30:00 1.1 0.4 2.3 0.4 1.2 0.5 2.3 0.4 1.2 0.3 2.3 0.7 301 5 297 165 8.5 0.1 8.5 8 06/01/2006 02:40:00 0.4 0 0.7 0.4 0.4 0 0.4 0.4 0.4 0.2 1.1 0.4 304 2 306 165 8.3 0.2 8.8 8 06/01/2006 02:50:00 0.4 0.2 1.1 0.4 0.4 0.2 1.1 0.4 0.6 0.3 1.5 0.4 25 90 123 165 8.2 0.2 8.5 7.8 06/01/2006 03:00:00 0.4 0.1 1.1 0.4 0.4 0 0.4 0.4 0.5 0.2 1.5 0.4 123 0 122 165 8 0.1 8.5 7.5 06/01/2006 03:10:00 0.4 0 0.7 0.4 0.4 0 0.4 0.4 0.6 0.3 1.5 0.4 17 76 325 165 7.9 0.3 8.5 7.3 06/01/2006 03:20:00 0.6 0.2 1.1 0.4 0.6 0.3 1.1 0.4 1 0.3 1.5 0.4 325 0 325 165 7.7 0.2 8 7.3 06/01/2006 03:30:00 1 0.7 2.6 0.4 0.8 0.6 2.3 0.4 1 0.7 2.6 0.4 349 22 10 165 7.6 0.1 8 7.3 06/01/2006 03:40:00 2.3 0.5 3.4 1.1 1.8 0.6 3.4 0.4 2.4 0.4 3.4 1.5 2 11 353 165 7.9 0.2 8 7.3 06/01/2006 03:50:00 3.3 0.3 3.8 2.3 2 0.5 3.8 1.1 3.6 0.4 4.2 2.6 1 5 349 165 7.8 0.2 8 7.3 06/01/2006 04:00:00 4 0.5 4.9 2.6 3.3 0.9 5.3 1.5 4 0.4 5.3 3 354 7 350 165 7.6 0 8 7.3 06/01/2006 04:10:00 3.3 0.4 4.6 2.3 3.1 0.7 4.6 1.5 3.6 0.3 4.2 2.6 348 8 338 165 7.8 0 7.8 7.3 06/01/2006 04:20:00 3.6 0.6 4.9 2.3 2.9 1 5.3 1.1 3.7 0.5 4.9 2.6 355 9 346 165 7.7 0 7.8 7.3 06/01/2006 04:30:00 2.9 0.5 4.2 2.3 2.5 0.7 4.2 1.1 3.1 0.6 4.9 2.3 15 5 17 165 7.8 0 7.8 7.3 06/01/2006 04:40:00 3.8 0.5 5.3 2.6 2.8 0.7 4.9 1.5 4 0.5 5.3 2.6 360 9 359 165 7.8 0 8.3 7.3 06/01/2006 04:50:00 4 0.3 4.9 3 2.8 0.7 4.9 1.5 4.1 0.3 4.9 3 0 8 357 165 7.7 0 8.3 7 06/01/2006 05:00:00 3.6 0.5 4.9 2.3 3.1 0.9 4.9 1.5 3.8 0.5 4.9 2.6 354 9 349 165 7.7 0 7.8 7 06/01/2006 05:10:00 4 0.6 5.7 2.6 4 0.8 5.7 1.9 4.1 0.6 5.7 3 345 6 349 165 7.6 0 7.8 7 06/01/2006 05:20:00 4.4 0.7 5.7 3 4.5 0.7 6.1 3 4.5 0.6 5.7 3.4 340 5 335 165 7.6 0 7.8 7.3 06/01/2006 05:30:00 3.7 0.3 4.6 3 3.8 0.4 4.6 2.6 3.8 0.3 4.6 3 342 5 350 165 7.8 0 8 7.5 06/01/2006 05:40:00 4.3 0.5 5.3 3 4.2 0.7 5.3 1.9 4.3 0.5 5.7 3 343 7 338 165 7.8 0 8 7.5 06/01/2006 05:50:00 4.6 0.4 5.7 3.4 4.6 0.6 5.7 2.3 4.7 0.5 5.7 3.4 341 7 336 165 8 0.1 8.3 7.5 06/01/2006 06:00:00 5.1 0.6 6.5 3.4 5.1 0.7 6.5 2.6 5.2 0.5 6.5 3.8 344 6 341 165 8 0.1 8.5 7.5 06/01/2006 06:10:00 3.7 0.8 6.1 2.3 3.1 1.2 6.5 1.1 3.9 0.7 5.7 2.6 352 7 344 165 8.1 0 8.3 7.5 06/01/2006 06:20:00 3 0.5 4.2 1.5 2.5 0.6 4.2 1.1 3.2 0.5 4.2 1.9 356 9 339 165 8.3 0.1 8.5 7.8 06/01/2006 06:30:00 3.1 0.5 4.6 1.9 3.1 0.6 4.6 1.5 3.2 0.5 4.6 2.3 329 11 330 165 8.7 0 9 8 06/01/2006 06:40:00 2.7 0.7 4.2 1.1 2.8 0.6 4.2 1.5 2.8 0.5 4.2 1.5 319 10 303 165 8.8 0 9 8.5 06/01/2006 06:50:00 2.2 0.4 3.4 1.1 2 0.6 3.4 0.4 2.5 0.5 3.8 1.5 344 12 350 165 9 0.1 9.3 8.5 06/01/2006 07:00:00 1.5 0.6 3 0.4 1.4 0.7 3 0.4 1.7 0.7 3 0.4 19 9 4 165 9.3 0 9.6 9 06/01/2006 07:10:00 0.9 0.5 2.3 0.4 0.8 0.5 2.3 0.4 1.2 0.4 1.9 0.4 24 12 38 165 9.6 0.2 10.1 8.8 06/01/2006 07:20:00 1.3 0.5 2.6 0.4 0.9 0.5 2.3 0.4 1.4 0.6 2.6 0.4 5 9 5 165 10 0.2 10.3 9.6 06/01/2006 07:30:00 1.6 0.6 3 0.4 1.6 0.7 3 0.4 1.9 0.6 3.4 0.4 20 32 27 165 10.1 0 10.6 9.8 06/01/2006 07:40:00 0.8 0.5 2.6 0.4 0.8 0.5 2.6 0.4 0.9 0.5 2.3 0.4 53 72 50 165 10.4 0.2 10.9 10.1 06/01/2006 07:50:00 0.8 0.5 2.6 0.4 0.8 0.6 2.6 0.4 1.2 0.5 2.6 0.4 136 11 140 165 10.4 0.2 10.9 10.3 06/01/2006 08:00:00 1.2 0.8 3.4 0.4 1.2 0.8 3.4 0.4 1.2 0.7 3.4 0.4 65 58 41 165 10.5 0.2 10.9 10.1 06/01/2006 08:10:00 1.9 0.7 3.8 0.4 1.9 0.7 3.8 0.4 2 0.7 4.2 0.4 30 10 35 165 10.9 0.1 11.1 10.1 06/01/2006 08:20:00 1.9 0.7 3.4 0.4 1.4 0.6 3 0.4 1.9 0.6 3 0.4 3 16 1 165 10.7 0.2 10.9 10.1 06/01/2006 08:30:00 3.2 0.5 4.9 1.9 2.7 0.6 4.6 1.1 3.2 0.6 4.6 1.1 10 11 19 165 10.9 0 11.1 10.3 06/01/2006 08:40:00 4.2 0.6 5.3 2.3 3.4 1.1 5.3 1.1 4.1 0.5 5.3 2.6 357 9 11 165 10.4 0.1 11.1 10.3 06/01/2006 08:50:00 4.3 0.5 5.7 3 4 0.8 5.7 1.9 4.1 0.5 5.7 3 348 8 347 165 11.4 0.2 11.7 10.9 06/01/2006 09:00:00 4.4 0.5 5.7 3.4 3.9 0.8 5.7 1.9 4.3 0.5 5.3 3 348 7 350 165 11.4 0 11.7 11.1 06/01/2006 09:10:00 4.6 0.5 5.7 3 4 1 6.1 1.9 4.6 0.6 6.1 3.4 349 8 341 165 11.7 0.3 12.2 11.1 06/01/2006 09:20:00 4.5 0.5 6.8 3.4 3.9 1 6.8 1.5 4.5 0.6 6.1 3 348 10 331 165 11.7 0 11.9 11.4 06/01/2006 09:30:00 5 0.6 6.8 3.4 4.7 0.7 6.5 2.6 5 0.6 6.5 3.4 343 10 353 165 11.6 0.2 12.2 11.1 06/01/2006 09:40:00 4.4 0.5 6.1 3 4.2 0.6 5.7 2.3 4.5 0.6 5.7 3 344 7 341 165 12.5 0.1 12.7 11.9 06/01/2006 09:50:00 4.1 0.6 5.7 2.3 4 0.7 5.7 1.9 4 0.6 5.7 2.3 339 9 338 165 12.3 0 12.7 11.9 06/01/2006 10:00:00 3.6 0.5 4.6 2.3 3.4 0.7 4.9 1.9 3.5 0.5 4.9 1.9 342 14 346 165 12.7 0.1 13 12.5 06/01/2006 10:10:00 3.1 1.1 5.3 0.7 2.7 1.1 5.3 0.7 2.8 1.2 5.3 0.4 344 20 346 165 12.8 0.1 13 12.5 06/01/2006 10:20:00 4.7 0.9 6.8 3 4 0.9 6.8 1.9 4.4 1 6.8 2.3 355 15 360 165 12.9 0 13.3 12.7 06/01/2006 10:30:00 5.7 0.7 7.2 3.8 4.6 0.8 7.2 2.6 5.6 0.8 7.6 3.4 2 12 11 165 12.7 0.1 13 12.2 06/01/2006 10:40:00 5.8 0.6 7.2 4.2 4.8 1 7.6 2.6 5.6 0.7 6.8 3.8 359 11 340 165 12.8 0 13 12.5 06/01/2006 10:50:00 5.6 1 8 3 4.8 1.1 8 2.6 5.5 1.1 8 3 359 15 12 165 12.5 0 12.7 11.9 06/01/2006 11:00:00 6.9 0.7 8.8 4.9 6.6 0.7 8.4 3.8 7.1 0.8 9.1 4.6 23 6 18 165 11.5 0.5 12.5 10.9 06/01/2006 11:10:00 7.5 0.8 9.1 4.9 7.3 0.8 9.1 4.6 7.7 0.9 9.5 5.3 24 7 26 165 10.7 0.2 11.4 10.3 06/01/2006 11:20:00 7.6 0.6 9.1 5.7 6.3 1.1 8.8 3.4 7.7 0.6 9.5 5.7 13 6 7 165 10.8 0.1 11.1 10.3 06/01/2006 11:30:00 7.8 0.6 9.1 5.7 6.6 1.1 8.8 3.8 7.8 0.7 9.5 5.7 13 7 16 165 10.7 0.1 11.1 10.1 06/01/2006 11:40:00 7 0.8 9.5 4.9 5.9 1.2 8.8 3 7.1 0.9 9.5 4.9 14 7 15 165 10.7 0.1 11.1 10.3 06/01/2006 11:50:00 6.4 0.6 8.8 4.6 5.2 1 8 2.6 6.6 0.7 8.8 4.6 11 8 16 165 11.3 0 11.7 10.6 06/01/2006 12:00:00 5.9 0.7 7.6 3.8 4.7 1 7.2 2.3 6 0.6 7.6 3.8 10 9 19 165 11.5 0 11.9 11.1 06/01/2006 12:10:00 5.9 0.7 8 4.2 5 0.8 7.2 3 6 0.8 8 4.2 14 11 7 165 11.9 0 11.9 11.7 06/01/2006 12:20:00 6.1 0.7 8 3.8 5.5 0.9 7.6 3 6.2 0.7 8 4.2 13 15 357 165 11.8 0.3 12.2 11.4 06/01/2006 12:30:00 5.6 0.8 7.6 3.4 4.8 1 6.8 2.6 5.5 0.8 7.6 3.4 4 15 360 165 12.1 0.4 13 11.1 06/01/2006 12:40:00 5.5 0.8 7.2 3.8 4.8 0.9 6.8 2.6 5.4 0.9 7.2 3 10 14 359 165 12.8 0.2 13 12.5 06/01/2006 12:50:00 5.8 0.8 8 3.8 5.1 1.1 8 2.3 5.8 0.9 8.4 3.8 5 13 344 165 13.1 0.2 13.5 12.5 06/01/2006 13:00:00 5.5 1 8.4 3 4.4 1 7.6 2.6 5.4 1.1 8.4 3 3 14 356 165 12.9 0.2 13.3 12.5 06/01/2006 13:10:00 5.1 0.7 7.2 3 4.7 0.8 6.8 2.3 5.1 0.8 7.6 3 20 12 13 165 12.3 0.2 13 11.9 06/01/2006 13:20:00 4.8 0.7 6.8 2.3 4.5 0.8 6.1 1.9 4.9 0.7 7.2 2.6 20 12 15 165 11.8 0 12.2 11.7 06/01/2006 13:30:00 4.9 0.8 6.8 2.6 4.5 1 6.8 2.3 4.9 0.9 6.8 2.3 18 15 15 165 12.2 0.4 12.7 11.4 06/01/2006 13:40:00 4.9 0.8 6.8 2.6 4.7 0.9 6.8 2.3 4.8 0.8 7.2 2.6 355 28 10 165 12.7 0.2 13 12.2 06/01/2006 13:50:00 4.7 0.6 6.1 2.6 4.2 0.8 6.1 2.3 4.6 0.7 6.1 1.9 13 17 43 165 12.8 0.2 13.3 12.5 06/01/2006 14:00:00 5.6 0.9 7.2 2.6 5.1 1.2 7.6 2.3 5.3 1 7.6 2.3 351 9 349 165 13.7 0.1 14.1 13 06/01/2006 14:10:00 6.1 0.6 7.6 4.6 5.8 0.8 7.6 3 6 0.6 7.2 4.2 345 7 353 165 13.5 0.1 14.4 13.3 06/01/2006 14:20:00 5.9 0.7 8 4.2 5.6 1.1 8 2.6 5.9 0.7 8 3.8 345 9 354 165 13.3 0.2 13.8 12.7 06/01/2006 14:30:00 5.1 0.6 6.5 3.4 4.5 1 6.5 2.3 5.1 0.7 6.8 3.4 347 11 345 165 14.4 0.2 14.6 13.5 06/01/2006 14:40:00 4.9 0.9 7.2 2.6 4.9 0.9 7.2 2.6 4.7 0.8 6.8 2.3 333 17 341 165 15.1 0.3 15.7 14.6 06/01/2006 14:50:00 4.7 0.6 6.1 2.6 4.3 0.9 6.1 2.3 4.7 0.6 6.5 2.6 348 9 344 165 14.5 0.5 15.2 13.8 06/01/2006 15:00:00 3.6 1 6.1 1.1 3.4 1 6.1 1.1 3 1.1 5.3 0.4 331 28 348 165 13.6 0 13.8 13.3 06/01/2006 15:10:00 3.8 0.7 6.1 2.3 3.8 0.8 5.7 1.9 3.6 0.7 5.7 2.3 333 15 321 165 13.8 0.2 14.1 13.3 06/01/2006 15:20:00 4.2 0.7 5.7 2.3 4.2 0.7 6.1 2.6 3.4 0.6 4.9 1.9 306 17 304 165 12.9 0.2 13.3 12.5 06/01/2006 15:30:00 4.7 0.9 6.8 3 4.7 0.9 6.8 2.6 4.1 0.9 6.1 1.9 294 9 304 165 12.3 0 12.7 11.7 06/01/2006 15:40:00 5.1 0.8 7.2 3 5.1 0.8 7.2 3 4.6 1 6.8 2.6 312 12 328 165 12.3 0 12.5 12.2 06/01/2006 15:50:00 4.7 0.5 6.1 3 4.7 0.5 6.1 3.4 4.1 0.6 6.1 1.9 311 10 298 165 12.8 0.1 13 12.5 06/01/2006 16:00:00 5.4 1 8.4 3.4 5.3 1 8.4 3 4.8 1.2 8.4 2.6 314 16 316 165 12.4 0.3 13 11.9 06/01/2006 16:10:00 4.6 0.6 6.1 2.6 4.6 0.6 6.5 2.6 4.1 0.7 5.7 2.3 309 10 326 165 11.7 0 12.2 11.4 06/01/2006 16:20:00 4.5 0.6 6.1 2.3 4.5 0.7 6.1 2.3 4.4 0.7 6.1 2.6 326 16 303 165 11.9 0 12.2 11.7 06/01/2006 16:30:00 4.4 0.8 6.8 1.9 4.2 0.9 6.5 1.9 4 0.9 6.5 1.9 323 22 322 165 12.3 0 12.7 11.9 06/01/2006 16:40:00 4.9 0.5 7.2 3.4 4.9 0.5 6.8 3.4 4 0.6 5.7 2.3 301 9 303 165 11.8 0.2 12.2 11.4 06/01/2006 16:50:00 4.8 0.8 6.8 2.6 4.8 0.8 6.8 2.6 4.3 0.8 6.5 2.3 311 13 310 165 11.3 0.3 11.7 10.9 06/01/2006 17:00:00 4.4 0.7 6.5 1.5 4.4 0.7 6.5 1.9 3.8 0.6 5.7 2.3 304 9 310 165 11.4 0.3 11.9 10.9 06/01/2006 17:10:00 4 0.6 5.7 1.9 4 0.6 5.7 2.3 3.5 0.7 4.9 1.9 314 13 309 165 11.8 0.3 12.5 10.9 06/01/2006 17:20:00 2.8 0.8 4.9 0.7 2.8 0.8 4.9 1.1 2.3 0.9 4.6 0.4 308 29 323 165 12.1 0.1 12.5 11.7 06/01/2006 17:30:00 3.2 0.5 4.6 1.9 3 0.6 4.6 1.5 2.9 0.7 4.6 1.1 327 26 343 165 12 0 12.5 11.7 06/01/2006 17:40:00 4 0.9 6.1 1.9 3.9 1 6.5 1.9 3.8 0.8 6.1 1.9 335 13 329 165 12.4 0.1 12.7 11.9 06/01/2006 17:50:00 3.8 1.1 6.8 1.9 3.7 1.1 6.5 1.9 3.4 1 6.1 1.1 333 15 338 165 12.4 0 12.7 12.2 06/01/2006 18:00:00 4.1 0.8 6.5 2.3 3.8 1 6.5 2.3 3.7 0.7 5.7 2.3 345 10 336 165 12.9 0.2 13.5 12.5 06/01/2006 18:10:00 4 0.8 6.1 2.3 4 0.8 5.7 1.9 3.7 0.9 6.1 1.5 336 13 333 165 14 0.2 14.4 13.5 06/01/2006 18:20:00 3.7 1.2 6.8 1.5 3.6 1.3 6.8 1.5 3.1 1.3 6.8 0.7 329 18 325 165 13.9 0.3 14.9 13 06/01/2006 18:30:00 4.6 0.8 6.5 2.3 4.4 1 6.5 1.9 3.9 1 6.1 1.5 331 17 299 165 12.5 0.2 13.8 12.2 06/01/2006 18:40:00 3.8 0.7 5.7 2.3 3.6 0.7 5.7 1.9 3.5 0.7 5.3 1.5 337 17 353 165 12.5 0 12.7 12.5 06/01/2006 18:50:00 4.2 0.7 6.1 2.3 4.1 0.7 6.1 2.3 3.9 0.7 5.7 2.3 325 20 354 165 12.3 0.2 12.7 11.9 06/01/2006 19:00:00 4.6 0.6 6.5 3 4.4 0.7 6.5 2.3 4.5 0.7 6.1 3 342 10 344 165 12.1 0.2 12.5 11.7 06/01/2006 19:10:00 4.7 0.7 7.2 3 4.7 0.6 6.8 3 4.2 0.8 6.8 2.6 310 15 336 165 12.6 0.1 13 12.2 06/01/2006 19:20:00 4.2 0.6 5.3 2.3 4.3 0.6 5.7 2.3 3.5 0.7 4.9 1.9 306 13 324 165 12.4 0.1 13 11.9 06/01/2006 19:30:00 4.2 0.8 6.8 2.6 4.3 0.8 7.2 2.6 3.6 0.7 5.7 1.9 307 12 305 165 11.9 0.3 12.5 11.1 06/01/2006 19:40:00 5.3 0.7 6.8 3.4 5.2 0.7 6.5 3 4.3 0.7 6.1 2.3 305 7 297 165 11.6 0.1 11.9 11.1 06/01/2006 19:50:00 6.5 1.1 9.1 3.4 6.5 1 9.1 3.4 5.3 1 8.4 2.3 305 9 305 165 11.5 0 11.9 11.1 06/01/2006 20:00:00 6.5 0.8 8.8 4.6 6.5 0.8 9.1 4.2 5.5 1 8.4 3 307 10 300 165 11.6 0.1 11.9 10.9 06/01/2006 20:10:00 6.9 1 9.1 4.2 6.8 1 9.1 4.2 6 0.9 8.8 3.4 314 12 305 165 11.5 0 11.9 11.1 06/01/2006 20:20:00 7.1 1.1 11.1 3.8 7.1 1.1 10.7 3.8 6.2 1.1 9.1 3.4 310 10 324 165 11.1 0.1 11.7 10.9 06/01/2006 20:30:00 6.7 0.7 9.1 4.6 6.6 0.7 9.1 4.6 5.8 0.8 7.6 3.4 315 13 294 165 10.6 0 11.1 10.3 06/01/2006 20:40:00 6.5 0.9 9.1 4.6 6.4 0.9 8.8 4.6 6 0.9 8.4 3.4 327 13 320 165 10.3 0 10.6 10.1 06/01/2006 20:50:00 6.4 0.9 9.1 4.2 6.4 0.9 9.1 4.2 5.7 1.1 9.1 2.6 314 9 313 165 10.2 0 10.6 9.8 06/01/2006 21:00:00 6.7 0.9 8.8 4.9 6.6 0.8 8.8 4.9 6.4 1 8.8 4.2 332 13 325 165 10.2 0 10.3 10.1 06/01/2006 21:10:00 6.4 1 8.8 3.8 6.3 1 9.1 3.4 5.8 1.2 8 1.9 320 10 343 165 9.9 0.1 10.3 9.6 06/01/2006 21:20:00 6.6 1.5 10.7 3.8 6.4 1.4 11.5 3.8 6.3 1.6 11.8 3.4 333 13 348 165 9.6 0 9.8 9.3 06/01/2006 21:30:00 6.9 1.2 10.7 4.2 6.8 1.2 10.7 3.8 6.6 1.2 9.1 3.8 332 9 354 165 9.6 0 9.8 9.3 06/01/2006 21:40:00 4.4 0.8 6.5 2.6 4.4 0.8 6.8 2.6 4 0.8 6.5 1.9 317 11 314 165 9.4 0 9.6 9 06/01/2006 21:50:00 4.1 0.9 7.6 2.3 4 0.9 7.6 1.5 3.8 1 6.1 1.5 335 13 329 165 9.3 0.2 9.6 8.8 06/01/2006 22:00:00 4.7 0.8 6.8 3 4.4 0.9 6.8 2.6 4.3 0.7 6.1 2.3 339 12 349 165 9.4 0.2 9.6 9 06/01/2006 22:10:00 5 1 6.8 2.3 4.8 1 6.8 1.9 4.7 0.8 6.8 3 332 17 351 165 9.2 0 9.6 9 06/01/2006 22:20:00 4.4 0.6 6.5 2.6 4.4 0.6 6.1 2.6 4.1 0.6 5.7 2.3 320 10 313 165 8.9 0.2 9.6 8.3 06/01/2006 22:30:00 5.8 0.6 7.6 4.2 5.7 0.7 7.6 3 5.4 0.7 6.8 3.4 319 12 329 165 8.7 0.1 9 8.3 06/01/2006 22:40:00 5.9 0.8 7.6 3.8 5.8 0.8 7.6 3.8 5 0.7 7.2 3 311 8 310 165 8.5 0 8.8 8 06/01/2006 22:50:00 6.1 0.9 8.4 3.4 6 0.8 8.4 3.8 5.5 1 7.6 3 315 8 312 165 8.3 0.1 8.5 8 06/01/2006 23:00:00 6.8 0.8 8.8 4.9 6.8 0.7 8.8 4.9 5.8 0.7 7.6 3.4 310 6 307 165 8.5 0 8.8 8.3 06/01/2006 23:10:00 7.5 0.8 9.5 4.9 7.5 0.8 9.9 5.3 6 1 9.5 3.4 306 8 307 165 8.7 0 9 8.3 06/01/2006 23:20:00 7.9 1 9.9 5.3 7.8 1 9.9 5.3 6.3 0.9 8.8 4.2 302 7 301 165 8.8 0 9 8.5 06/01/2006 23:30:00 6.4 0.8 8.4 4.6 6.4 0.8 8 4.6 5.6 0.9 7.6 3 311 6 315 165 8.5 0 9 8.3 06/01/2006 23:40:00 6.4 1.1 9.5 3.8 6.3 1 9.5 3.8 5.6 1.2 9.5 3.4 311 8 316 165 8.5 0 8.8 8.3 06/01/2006 23:50:00 7.5 0.7 9.1 5.3 7.4 0.7 9.1 5.3 6.7 0.9 9.5 4.2 313 7 316 165 8.7 0 9 8.5 06/02/2006 00:00:00 6.8 1 10.3 4.2 6.7 1 10.3 4.6 6.1 1.1 9.5 3.4 314 9 339 165 8.7 0 9 8.5 06/02/2006 00:10:00 6.6 1.1 9.9 3.8 6.4 1 9.9 3.8 5.7 1.1 9.5 3 322 11 326 165 8.8 0 9 8.5 06/02/2006 00:20:00 6 0.9 8.4 4.2 5.9 0.8 8 4.2 5.5 0.9 7.6 3 325 11 328 165 8.9 0 9 8.5 06/02/2006 00:30:00 6.2 1 9.9 3.8 6.1 1 9.9 3.4 5.5 1.3 9.9 3 316 11 320 165 8.9 0 9 8.5 06/02/2006 00:40:00 6.2 1.1 8.8 3 6.2 1.1 8.4 3 6 1.1 8.4 2.6 325 12 340 165 9.1 0.1 9.3 8.8 06/02/2006 00:50:00 6.1 1 8.8 3.4 6.1 1 8.8 3.8 5.5 1 8 2.6 324 15 328 165 9.1 0 9.3 8.8 06/02/2006 01:00:00 5.4 1.1 8 3 5.3 1.1 8 3 4.9 1.1 8.4 2.3 322 12 338 165 9 0 9 8.5 06/02/2006 01:10:00 4.8 1.1 9.1 2.6 4.7 1 8.8 3 4.4 0.9 8 2.6 330 12 351 165 8.9 0 9 8.5 06/02/2006 01:20:00 5.7 1.3 9.9 3 5.6 1.3 9.5 3.4 5.3 1.3 9.9 2.6 328 15 354 165 9.2 0 9.3 8.8 06/02/2006 01:30:00 6.3 1 9.5 4.2 6.3 1 9.1 4.2 5.6 1 9.5 3.4 319 12 332 165 8.9 0.1 9.3 8.5 06/02/2006 01:40:00 8.1 1.1 10.3 4.9 8.1 1.1 10.7 4.9 7.6 1.1 9.9 4.6 329 11 336 165 9.2 0.1 9.6 8.5 06/02/2006 01:50:00 8.8 1.2 11.8 5.3 8.7 1.2 11.8 5.3 8.2 1.1 10.7 6.1 336 6 329 165 9.9 0.1 10.3 9 06/02/2006 02:00:00 8.4 1.2 11.1 4.6 8.4 1.2 11.1 4.6 8.1 1.2 11.1 5.3 337 9 343 165 10 0.1 10.3 9.6 06/02/2006 02:10:00 7.9 1.3 10.7 4.6 7.7 1.4 10.7 4.6 7.1 1.3 10.3 4.6 337 9 338 165 9.8 0 10.1 9.3 06/02/2006 02:20:00 7.5 1 9.9 5.3 7.3 1.1 10.3 4.6 7.1 1 9.9 4.9 337 9 329 165 9.8 0 10.1 9.3 06/02/2006 02:30:00 6.7 1.2 10.7 3.8 6.5 1.2 10.3 3.4 6.4 1.1 9.9 3.8 335 9 325 165 9.8 0.2 10.1 9.3 06/02/2006 02:40:00 7.5 1.2 10.7 5.3 7.4 1.2 11.1 4.9 7 1.2 10.3 4.6 329 13 336 165 10 0.1 10.3 9.6 06/02/2006 02:50:00 7.6 1.4 10.7 3.8 7.5 1.4 10.7 3.8 6.9 1.4 9.5 3 324 13 336 165 9.8 0.1 10.1 9.3 06/02/2006 03:00:00 9.2 1.6 14.5 6.5 9.1 1.6 14.9 6.8 8.6 1.5 13.3 5.7 328 9 344 165 10 0.2 10.3 9.3 06/02/2006 03:10:00 8.2 1.2 11.1 4.9 8 1.2 11.1 4.6 7.6 1.3 11.1 4.2 328 10 343 165 10.1 0.1 10.6 9.6 06/02/2006 03:20:00 7.7 1 9.9 5.3 7.6 1 10.3 4.9 7 1 10.3 4.2 325 12 339 165 10.1 0.1 10.6 9.6 06/02/2006 03:30:00 7.7 0.8 9.9 5.7 7.5 0.8 9.9 4.9 7.1 0.9 9.5 4.6 320 8 306 165 9.4 0.1 9.8 9 06/02/2006 03:40:00 6.9 0.9 9.1 4.6 6.8 0.8 9.1 4.2 6.1 0.9 8.4 3.8 319 9 325 165 9.3 0 9.6 8.8 06/02/2006 03:50:00 7.5 1 9.9 4.9 7.3 1 9.9 4.6 7 0.8 9.5 4.9 327 12 309 165 9.9 0.3 10.6 9 06/02/2006 04:00:00 7.9 1.1 11.1 5.7 7.7 1 11.5 5.3 7.6 1.2 11.1 5.3 330 13 347 165 10.4 0.1 10.9 9.8 06/02/2006 04:10:00 7.5 1.3 10.3 4.6 7.3 1.4 10.3 4.2 7.1 1.2 9.9 3.8 326 18 310 165 10.5 0 10.9 10.3 06/02/2006 04:20:00 7.8 1.2 10.7 4.2 7.5 1.2 10.3 3.8 7.6 1.3 11.1 3.8 333 17 360 165 10.9 0.1 11.4 10.3 06/02/2006 04:30:00 8.3 1.2 12.2 4.9 8.3 1.3 12.6 5.3 7.9 1.3 12.6 5.3 324 15 343 165 11.1 0.2 11.7 10.9 06/02/2006 04:40:00 9 1.1 12.6 6.1 9 1.1 12.6 6.1 7.7 1.3 11.8 4.9 308 6 313 165 10.4 0.3 11.1 9.8 06/02/2006 04:50:00 8.6 1.2 12.2 5.7 8.6 1.2 12.2 5.3 7.2 1.2 11.1 4.9 307 12 304 165 10.4 0 10.6 10.3 06/02/2006 05:00:00 8.9 1.2 11.5 5.7 8.8 1.2 11.1 5.7 7.4 1 9.9 4.9 307 8 308 165 10.1 0 10.6 9.6 06/02/2006 05:10:00 8.9 1.1 12.2 5.3 8.9 1.1 11.8 5.3 7.2 1 11.1 4.6 305 7 302 165 10.2 0 10.3 10.1 06/02/2006 05:20:00 9.1 1.1 11.8 5.3 9.1 1.1 11.8 6.1 7.6 0.9 9.5 5.3 306 8 298 165 10.6 0.1 10.9 10.3 06/02/2006 05:30:00 10.1 1.1 12.6 6.1 10 1.1 13 6.1 8.3 1.1 12.6 5.3 303 8 302 165 10.7 0.1 11.1 9.8 06/02/2006 05:40:00 9.4 1.1 12.2 6.5 9.4 1.1 12.6 6.5 7.9 1.2 11.5 4.9 306 8 297 165 11 0.2 11.7 10.6 06/02/2006 05:50:00 9.1 1.7 12.6 4.6 9 1.6 12.6 4.9 7.5 1.3 11.5 3.4 307 10 305 165 10.9 0.2 11.4 10.6 06/02/2006 06:00:00 9.6 1.1 12.2 6.8 9.7 1.1 12.2 6.8 7.6 1 10.7 4.6 304 7 300 165 11 0.2 11.4 10.6 06/02/2006 06:10:00 9.3 0.9 11.5 6.8 9.3 1 11.5 6.8 7.4 1 10.3 4.9 305 7 293 165 11.1 0.2 11.7 10.6 06/02/2006 06:20:00 9 1.3 12.2 5.3 8.9 1.2 12.2 5.7 7.2 1.2 9.9 4.2 303 7 309 165 11.7 0.2 12.2 11.1 06/02/2006 06:30:00 8.4 1.1 11.5 5.7 8.3 1 11.1 6.1 6.9 1 9.1 4.6 306 8 296 165 12.1 0.2 12.5 11.7 06/02/2006 06:40:00 8.1 1 10.7 5.3 8 1 9.9 4.9 7 1.2 9.9 4.6 311 8 294 165 12.3 0 12.7 12.2 06/02/2006 06:50:00 7 1.5 9.9 2.6 6.9 1.4 9.9 2.3 6.1 1.2 9.1 2.3 313 16 312 165 12.7 0.2 13 12.5 06/02/2006 07:00:00 6.2 1.1 8.8 3.4 6.1 1.1 8.8 3.8 5.5 1 8 3.4 315 10 295 165 13.3 0 13.5 13 06/02/2006 07:10:00 6.3 0.9 8.8 4.6 6.2 0.9 8.4 4.2 5.7 1 8 3.4 322 10 326 165 13.5 0.1 13.5 13 06/02/2006 07:20:00 5.7 1.1 8.4 3.4 5.5 1.1 8 3.4 5.4 1.1 8 2.6 334 14 323 165 13.9 0.2 14.4 13 06/02/2006 07:30:00 5.3 1.4 8.8 2.6 5.3 1.5 8.4 2.3 4.9 1.5 8.4 1.9 326 15 319 165 14.4 0.2 14.9 13.8 06/02/2006 07:40:00 5.9 1 8.8 3 5.6 1 8.4 3 5.4 0.9 7.6 3.4 334 17 6 165 15 0 15.2 14.6 06/02/2006 07:50:00 5.5 0.9 8 3.4 5.3 0.9 7.6 3 5 0.9 7.6 3 333 12 359 165 15.5 0.3 15.7 14.9 06/02/2006 08:00:00 4.9 0.9 6.8 2.3 4.7 1 7.2 1.9 4.3 1 7.2 2.3 337 20 319 165 15.9 0.1 16.3 15.5 06/02/2006 08:10:00 4.9 0.8 7.2 2.3 4.7 1 7.2 1.9 4.5 0.8 6.5 2.6 328 19 319 165 15.6 0.2 16 15.5 06/02/2006 08:20:00 5.8 1.3 9.5 3 5.7 1.5 9.5 2.3 5.5 1.3 9.1 2.6 327 17 328 165 15.7 0.4 16.6 15.2 06/02/2006 08:30:00 5.9 0.8 8 3.8 5.4 1.3 8.4 2.6 5.7 1 9.1 3 337 17 332 165 15.2 0.1 16 15.2 06/02/2006 08:40:00 5.7 1.7 9.5 2.3 5.4 1.7 9.1 1.9 5.4 1.7 9.1 2.3 334 22 336 165 16.1 0.1 16.6 15.7 06/02/2006 08:50:00 6.2 0.8 8.4 4.2 6.2 0.8 8.4 4.2 6 1 8.4 3.8 323 12 339 165 15.3 0.2 16 14.9 06/02/2006 09:00:00 6.5 1 8.8 3.4 6.4 1 8.8 3.4 6.1 1 8.8 3.4 322 12 325 165 15.6 0.1 16.3 15.5 06/02/2006 09:10:00 6.5 1.1 9.5 3.8 6.4 1.1 9.1 3.8 5.8 1.5 8.8 2.3 320 17 322 165 15.9 0.2 16.3 15.5 06/02/2006 09:20:00 5.8 1 8 3 5.4 1 8 3.4 5.2 1.2 9.1 2.3 329 26 330 165 16.7 0 17.1 16.3 06/02/2006 09:30:00 5.9 1.3 9.9 1.9 5.9 1.2 9.9 1.9 5.1 1.2 9.5 1.1 307 19 274 165 16.1 0.3 16.8 15.7 06/02/2006 09:40:00 5.7 1.3 9.9 1.5 5.6 1.3 9.9 1.9 4.8 1.4 8.8 1.9 310 16 295 165 15.9 0.2 16.8 15.5 06/02/2006 09:50:00 5.2 1 7.6 3 5.2 1 7.2 2.6 4.4 1.1 7.6 1.5 304 12 285 165 16.9 0 17.7 16.8 06/02/2006 10:00:00 5.5 1 7.6 3 5.5 1 8 3 4.7 0.9 6.8 2.3 304 15 300 165 16.6 0.3 17.1 16.3 06/02/2006 10:10:00 5.1 1.1 8 2.3 5 1.1 8 2.3 4.3 1.1 7.6 1.5 300 15 302 165 17 0.1 17.4 16.6 06/02/2006 10:20:00 4.6 1 7.6 1.9 4.5 1.1 7.6 1.1 3.8 0.9 5.7 1.5 309 23 302 165 17.5 0.4 18 16.8 06/02/2006 10:30:00 5.8 1.3 10.3 3 5.4 1.4 10.3 2.3 5.4 1.2 8.8 3 345 29 329 165 17.8 0.2 18.2 17.4 06/02/2006 10:40:00 4 1 6.5 1.9 4 1.1 7.6 1.9 3.6 1.1 6.5 0.4 316 32 306 165 17.1 0.1 17.4 16.8 06/02/2006 10:50:00 4.5 1 6.8 1.9 4.5 1 6.5 1.9 4.1 1 6.1 1.5 315 14 305 165 17.7 0.5 18.5 16.8 06/02/2006 11:00:00 5.1 1.2 8.4 2.6 5 1.2 8.4 2.6 4.5 1.1 7.6 1.5 313 21 310 165 18.3 0.1 18.8 18 06/02/2006 11:10:00 4.7 1.3 8.8 0.7 4.7 1.3 8.4 0.7 4.1 1.2 8.4 1.1 304 26 302 165 18.2 0 18.5 18 06/02/2006 11:20:00 5.8 1.1 9.1 2.6 5.9 1.1 8.8 2.6 5 1.1 8 1.9 291 11 301 165 18 0.2 18.5 17.7 06/02/2006 11:30:00 6.3 1.2 9.5 3 6.3 1.2 9.1 3 5.4 1.2 8 2.3 304 13 281 165 18.1 0.1 18.5 17.7 06/02/2006 11:40:00 5.9 0.8 8 3.8 5.9 0.8 8.4 3.4 5.3 1 8.4 3 316 17 326 165 19 0.5 19.7 18 06/02/2006 11:50:00 5.9 1 9.1 3.4 5.9 1 9.9 3.8 5.3 1 8 3 297 12 297 165 18.2 0.4 19.4 17.7 06/02/2006 12:00:00 6.3 1.3 10.7 3 6.3 1.3 10.7 3 5.4 1.3 9.5 1.9 306 15 298 165 18.1 0.3 19.1 17.4 06/02/2006 12:10:00 6.7 1.3 9.5 3.8 6.6 1.3 9.9 3.4 5.7 1.3 8.8 1.9 316 18 299 165 19.1 0.2 19.7 18.8 06/02/2006 12:20:00 6.3 0.8 8.4 3.8 6 0.9 8.4 3.4 5.5 1 8 2.6 331 17 331 165 19.9 0.2 20.5 19.1 06/02/2006 12:30:00 6.7 1.5 9.9 3 6.7 1.5 9.5 3 5.8 1.5 8.8 2.3 312 15 315 165 19.2 0.7 20.2 18.2 06/02/2006 12:40:00 7.6 1 10.3 4.6 7.6 1 10.3 4.6 6.3 1.1 8.8 3.8 304 10 297 165 18.4 0.4 19.4 17.7 06/02/2006 12:50:00 7.6 1 11.1 4.9 7.6 1 11.1 4.9 6.2 1.1 11.5 3.8 301 8 286 165 18 0.1 18.5 17.7 06/02/2006 13:00:00 7.9 1.3 11.8 4.6 7.9 1.3 11.5 4.6 6.6 1.1 9.5 3.8 303 9 299 165 18.3 0.2 18.8 18 06/02/2006 13:10:00 8.2 0.9 11.5 6.1 8.2 0.9 10.7 5.7 6.9 1.1 9.5 4.2 306 9 309 165 18.2 0 18.5 18 06/02/2006 13:20:00 7.5 1.4 10.3 3.4 7.5 1.4 10.7 3.4 6.5 1.2 9.9 3.4 308 10 298 165 18.5 0.2 19.1 18 06/02/2006 13:30:00 7.3 1 9.9 4.9 7.3 0.9 9.9 4.9 6.2 1 8.8 3.8 299 9 300 165 19.2 0.1 19.7 18.8 06/02/2006 13:40:00 5.5 1 8 2.3 5.5 1 8 3 4.5 1 8 1.5 294 13 287 165 19.8 0.6 21.1 19.1 06/02/2006 13:50:00 5.5 1.3 10.3 2.6 5.5 1.3 10.3 2.6 4.4 1.2 8 1.9 292 13 274 165 20.6 0.2 21.1 20.2 06/02/2006 14:00:00 4.7 1.3 8.8 0.7 4.8 1.3 9.5 0.7 4.1 1.3 8 0.7 286 19 311 165 21 0.1 21.4 20.5 06/02/2006 14:10:00 4.8 1.5 7.6 0.4 4.9 1.5 7.6 0.7 3.8 1.3 6.8 0.4 290 32 298 165 20.5 0.3 21.1 20 06/02/2006 14:20:00 5 1.5 9.5 1.5 5.1 1.4 10.3 1.9 4.1 1.4 7.6 0.4 289 14 291 165 21 0.2 21.4 20.5 06/02/2006 14:30:00 4.1 1.4 7.2 1.1 4.2 1.3 7.2 0.7 3.3 1.3 7.6 0.7 280 33 328 165 20.3 0.6 21.1 19.1 06/02/2006 14:40:00 3.6 1.5 7.6 0.4 3.7 1.6 8 0.4 2.9 1.2 6.1 0.4 287 49 309 165 19.5 0.4 20.2 18.5 06/02/2006 14:50:00 3.7 1.5 8 0.7 3.7 1.5 8 0.4 2.6 1.3 5.7 0.4 280 35 289 165 17.8 0.2 18.5 17.4 06/02/2006 15:00:00 1.8 1 6.1 0.4 1.7 1 5.7 0.4 1.6 0.9 4.6 0.4 194 90 302 165 17.5 0 17.7 17.1 06/02/2006 15:10:00 1.9 1.2 6.1 0.4 1.9 1.2 6.1 0.4 2 1 5.7 0.4 191 66 165 165 17.8 0.2 18.2 17.4 06/02/2006 15:20:00 1.8 1.2 6.8 0.4 1.8 1.2 6.8 0.4 1.6 1 6.1 0.4 179 79 302 165 17.5 0.1 18 17.1 06/02/2006 15:30:00 3.2 1.6 6.5 0.4 3.1 1.5 6.5 0.4 2.2 1.5 7.6 0.4 332 82 214 165 17.9 0.3 18.5 17.4 06/02/2006 15:40:00 1.8 1 4.9 0.4 1.8 0.9 3.8 0.4 1.4 0.7 3.4 0.4 138 94 344 165 18.4 0.1 18.8 17.7 06/02/2006 15:50:00 1.9 0.7 4.2 0.4 1.9 0.7 4.2 0.4 1.9 0.7 3.8 0.4 162 53 213 165 18 0 18.2 17.7 06/02/2006 16:00:00 1.5 0.8 3.8 0.4 1.4 0.8 3.8 0.4 1.3 0.7 3 0.4 173 76 145 165 18.2 0 18.5 17.7 06/02/2006 16:10:00 2.6 0.9 5.3 0.4 2.6 0.8 5.3 0.4 2.3 0.8 4.6 0.4 165 79 335 165 17.2 0.4 18 16.6 06/02/2006 16:20:00 2.2 0.8 4.6 0.7 2.1 0.8 4.9 0.4 2 0.9 5.3 0.4 153 33 145 165 17 0.2 17.4 16.6 06/02/2006 16:30:00 2.5 0.6 4.2 1.1 2.5 0.6 4.2 1.1 2.5 0.8 4.6 0.7 139 19 159 165 16.6 0.3 17.1 16.3 06/02/2006 16:40:00 1.2 0.6 3 0.4 1.2 0.6 2.6 0.4 1.4 0.6 2.6 0.4 133 23 80 165 17.3 0.1 18 16.8 06/02/2006 16:50:00 1.8 1 6.1 0.4 1.8 1 5.7 0.4 1.5 0.8 3.4 0.4 172 64 302 165 17.4 0.1 17.7 17.1 06/02/2006 17:00:00 1.9 1.2 5.7 0.4 1.8 1.2 5.7 0.4 1.4 0.8 3.8 0.4 168 112 11 165 17.6 0.2 18 17.1 06/02/2006 17:10:00 1.9 0.9 4.9 0.4 1.9 0.9 4.6 0.4 1.9 1 4.9 0.4 159 22 143 165 16.9 0.1 17.4 16.6 06/02/2006 17:20:00 2.9 1.7 6.1 0.4 2.8 1.7 6.1 0.4 2.3 1.5 6.1 0.4 358 82 355 165 17.7 0.7 19.1 16.8 06/02/2006 17:30:00 4.4 1.5 7.2 1.1 4.4 1.6 7.2 1.1 3.5 1.7 6.5 0.4 327 27 302 165 19.2 0.2 20.2 18.8 06/02/2006 17:40:00 6.5 1.1 9.1 3.8 6.5 1.1 9.1 3.4 5.6 1 8 3 313 12 306 165 19.8 0.2 20.8 19.4 06/02/2006 17:50:00 6.6 0.8 9.1 4.2 6.6 0.8 9.1 4.6 5.6 0.9 8.8 3 306 8 306 165 19.6 0 20 19.4 06/02/2006 18:00:00 6.2 1.1 9.5 3.4 6.3 1.2 9.9 3.4 5.4 1.1 8.8 2.6 313 12 303 165 19.5 0 19.7 19.1 06/02/2006 18:10:00 6.7 1 9.1 4.2 6.6 1 9.1 4.6 5.7 1.1 8.4 3 310 12 318 165 19.2 0 19.4 19.1 06/02/2006 18:20:00 6.5 1 9.1 3.8 6.4 1 9.1 3.8 5.9 0.9 8.4 3.8 311 13 300 165 19.2 0.2 19.7 18.8 06/02/2006 18:30:00 6.2 1 9.1 3.8 6.2 1 9.5 3.8 5.8 1 9.9 3.4 323 16 324 165 19.7 0.2 20.2 19.4 06/02/2006 18:40:00 6.1 0.7 8 3 5.8 0.9 7.6 2.6 5.6 0.8 8 2.6 327 22 315 165 19.5 0 19.7 19.4 06/02/2006 18:50:00 6.3 1.2 9.9 3.8 6.1 1.1 9.9 3.8 5.8 1.3 9.9 1.9 333 17 347 165 19.4 0 19.7 19.1 06/02/2006 19:00:00 5.2 0.7 6.8 3.4 5.1 0.7 6.8 3.4 4.9 0.9 6.5 2.3 322 18 343 165 19.1 0 19.4 19.1 06/02/2006 19:10:00 5.1 0.7 6.8 3.4 5.1 0.7 6.8 3.4 4.8 0.8 6.8 3 320 9 317 165 19.3 0.2 19.7 19.1 06/02/2006 19:20:00 5.1 0.8 6.8 3.4 5.1 0.8 7.2 3 4.4 0.7 6.5 2.6 311 12 309 165 19.1 0.2 19.4 18.5 06/02/2006 19:30:00 5.8 0.8 8.4 4.2 5.8 0.8 8.4 4.2 5.3 0.8 7.2 3 313 8 312 165 18.4 0 18.5 18.2 06/02/2006 19:40:00 6 0.7 7.6 3.4 6 0.7 7.6 4.2 5.5 0.8 7.6 3.4 313 10 318 165 18.3 0 18.5 18.2 06/02/2006 19:50:00 5.7 0.7 7.6 4.2 5.6 0.6 7.2 4.2 5.3 0.8 7.6 3 322 12 328 165 18.5 0 18.5 18.2 06/02/2006 20:00:00 6.1 0.8 8 4.2 6.1 0.7 7.6 3.8 5.7 0.8 7.2 3.4 317 9 329 165 18.1 0 18.2 17.7 06/02/2006 20:10:00 7.5 0.9 9.5 5.3 7.4 0.9 9.5 5.3 6.6 1 9.1 4.2 310 8 313 165 17.5 0.1 18 17.4 06/02/2006 20:20:00 8.2 0.6 9.9 6.8 8.1 0.6 9.5 6.8 7.4 0.8 9.5 4.6 312 5 315 165 17.2 0 17.4 17.1 06/02/2006 20:30:00 7.8 0.7 9.9 5.7 7.7 0.7 9.9 5.7 6.9 0.9 9.5 4.6 310 7 313 165 16.8 0 17.1 16.8 06/02/2006 20:40:00 8.1 0.8 10.7 6.5 8 0.8 10.3 6.1 6.9 0.9 9.9 4.6 310 7 305 165 16.4 0.1 16.8 16 06/02/2006 20:50:00 8.5 0.7 10.7 6.5 8.4 0.7 10.3 6.5 7.2 1 9.9 4.6 309 6 314 165 16.1 0 16.6 15.7 06/02/2006 21:00:00 9 0.8 11.1 6.8 8.8 0.8 11.1 6.8 7.7 1 11.1 4.9 309 6 314 165 15.7 0 16 15.5 06/02/2006 21:10:00 9.7 0.8 11.8 8 9.5 0.8 11.8 7.6 8.3 1 11.8 5.3 308 5 302 165 15.2 0.2 15.7 14.9 06/02/2006 21:20:00 8.9 1 12.2 6.1 8.8 1 12.2 6.1 7.9 1 11.8 5.3 311 7 311 165 15 0.1 15.5 14.6 06/02/2006 21:30:00 10 1 12.6 7.6 9.9 1 12.2 7.6 8.8 1.1 12.6 6.5 312 7 305 165 14.9 0.1 15.2 14.6 06/02/2006 21:40:00 10.1 1 13.7 8 10 1 13.3 7.2 9.2 0.9 11.5 6.5 313 6 318 165 14.8 0.1 15.2 14.6 06/02/2006 21:50:00 10.3 0.9 13.3 8.4 10.2 0.9 13 8.4 9.5 0.9 12.2 7.2 313 6 309 165 14.6 0.1 15.2 14.4 06/02/2006 22:00:00 10.2 0.7 11.8 8 10.1 0.7 11.8 8 8.8 0.9 11.5 6.5 311 6 331 165 14.4 0.2 14.9 14.1 06/02/2006 22:10:00 10.4 0.8 12.2 8 10.3 0.7 11.8 8 8.9 1.1 11.8 6.1 311 6 307 165 14.5 0.2 14.9 14.1 06/02/2006 22:20:00 9.6 0.8 11.8 7.6 9.5 0.8 11.5 7.6 8.5 1 11.1 6.1 310 4 307 165 14.4 0.2 14.9 14.1 06/02/2006 22:30:00 8.8 0.8 10.7 6.8 8.8 0.8 10.7 6.8 7.7 0.7 9.9 5.3 310 5 306 165 14.4 0.1 14.6 14.1 06/02/2006 22:40:00 8.8 1.1 12.6 6.1 8.8 1.1 12.6 5.7 7.8 1.1 11.1 4.9 312 5 316 165 14.2 0 14.4 14.1 06/02/2006 22:50:00 9.2 0.9 11.8 7.2 9.1 1 11.8 7.2 8.1 1.1 10.7 5.3 312 6 311 165 14.5 0 14.6 14.4 06/02/2006 23:00:00 10 0.9 13 7.2 10 0.8 12.2 7.2 8.9 1 11.8 6.5 311 5 309 165 14.6 0 14.9 14.6 06/02/2006 23:10:00 10 0.9 11.8 6.8 9.9 0.9 11.8 6.8 8.8 1 11.1 5.7 311 5 307 165 14.7 0 15.2 14.4 06/02/2006 23:20:00 9.8 1.2 12.2 6.5 9.8 1.1 11.8 6.5 8.3 1.1 10.3 5.7 309 5 309 165 14.6 0 14.9 14.6 06/02/2006 23:30:00 10 0.8 12.2 7.6 9.9 0.8 11.8 7.6 7.8 0.9 9.9 5.3 306 4 303 165 14.5 0 14.6 14.1 06/02/2006 23:40:00 10.3 0.9 13 8 10.3 0.8 12.6 7.6 8.8 0.9 11.1 6.1 310 5 313 165 14.4 0 14.6 14.1 06/02/2006 23:50:00 10.4 0.8 12.2 7.6 10.4 0.8 12.2 7.2 8.5 0.8 10.3 6.5 308 4 307 165 14.4 0 14.9 14.1 06/03/2006 00:00:00 10.3 0.7 11.8 8.4 10.2 0.7 11.8 8 8.9 1 11.5 6.1 310 5 308 165 14.6 0 14.9 14.1 06/03/2006 00:10:00 11.4 0.8 13.3 9.1 11.2 0.7 13 9.1 10.3 0.9 11.8 7.6 313 3 310 165 14.4 0 15.2 14.1 06/03/2006 00:20:00 11.9 0.7 13.7 9.9 11.6 0.7 13.3 9.5 10.6 0.8 13 7.2 313 3 318 165 14.6 0 14.6 14.1 06/03/2006 00:30:00 11.7 0.7 13 9.5 11.4 0.7 13 9.5 10.2 0.8 12.2 7.6 312 3 307 165 14.5 0 14.6 13.8 06/03/2006 00:40:00 11.9 0.8 13.3 9.5 11.7 0.8 13.3 9.1 10.5 1 13.3 6.8 313 4 310 165 14.3 0 14.6 13.8 06/03/2006 00:50:00 12.8 0.7 14.5 9.9 12.6 0.7 14.5 10.3 11.3 0.9 13.3 8.8 312 3 314 165 14.3 0 14.6 13.8 06/03/2006 01:00:00 13.6 0.8 15.6 11.5 13.3 0.8 15.3 11.5 12.1 1.1 15.3 9.5 313 4 318 165 14.4 0 14.6 13.8 06/03/2006 01:10:00 14.2 0.7 15.6 11.5 13.9 0.7 15.3 11.5 12.8 1 14.9 9.5 313 3 312 165 14.4 0 14.9 13.8 06/03/2006 01:20:00 14.5 0.7 16.4 12.2 14.3 0.7 16.1 11.8 13 0.9 15.6 9.9 312 3 316 165 14.6 0.1 14.9 14.1 06/03/2006 01:30:00 14.6 0.8 16.4 12.2 14.4 0.8 16.1 11.5 13.4 1 15.3 10.3 313 3 314 165 14.5 0 14.6 14.1 06/03/2006 01:40:00 14.8 0.9 16.4 12.2 14.5 0.9 16.4 12.2 13.7 1 16.1 9.5 314 3 309 165 14.5 0.1 14.6 14.1 06/03/2006 01:50:00 14.7 0.8 16.8 12.2 14.4 0.8 16.8 11.8 13.1 1 16.1 10.3 313 3 310 165 14.5 0 14.9 13.8 06/03/2006 02:00:00 14.5 0.9 16.4 12.2 14.2 0.9 16.1 11.8 13 1.1 15.3 9.1 313 3 312 165 14.5 0 14.6 13.8 06/03/2006 02:10:00 14.9 0.7 16.8 12.6 14.6 0.8 16.4 12.6 13.3 1 16.1 9.5 313 3 309 165 14.4 0 14.6 13.8 06/03/2006 02:20:00 15.1 0.8 17.2 12.2 14.9 0.8 16.4 11.8 13.8 1.1 16.4 10.3 313 3 316 165 14.4 0 14.6 13.8 06/03/2006 02:30:00 14.9 0.6 16.4 13 14.7 0.7 16.4 12.2 13.1 1.1 16.4 9.9 311 2 314 165 14.5 0 14.6 14.1 06/03/2006 02:40:00 14.6 0.7 16.8 11.5 14.5 0.7 16.8 11.8 12.6 1.1 15.3 9.9 311 3 310 165 14.4 0 14.9 14.1 06/03/2006 02:50:00 14.5 0.8 16.1 11.1 14.3 0.8 15.6 11.1 12.6 1.1 14.9 9.5 310 3 307 165 14.3 0 14.6 13.8 06/03/2006 03:00:00 14.7 0.7 16.1 12.2 14.6 0.8 16.1 11.8 12.5 1.1 15.3 9.1 310 3 310 165 14.3 0 14.6 13.8 06/03/2006 03:10:00 15 0.8 17.2 11.8 14.8 0.8 16.8 12.2 13.2 1.1 16.1 10.3 311 3 311 165 14.3 0 14.6 13.8 06/03/2006 03:20:00 14.6 0.7 16.1 12.2 14.4 0.8 16.1 11.8 12.8 1 15.3 9.9 311 3 314 165 14.4 0 14.6 14.1 06/03/2006 03:30:00 14.3 0.8 16.1 11.5 14.1 0.8 16.1 11.1 12.7 1 14.9 9.5 312 3 310 165 14.3 0 14.6 14.1 06/03/2006 03:40:00 14.4 0.8 16.1 11.8 14.3 0.8 15.6 11.5 12.4 1.1 15.3 8.8 311 4 317 165 14.4 0 14.6 14.1 06/03/2006 03:50:00 14.1 0.8 16.1 11.5 13.9 0.8 16.1 11.1 12.4 1 14.9 9.5 312 4 310 165 14.4 0 14.6 14.4 06/03/2006 04:00:00 13.6 0.8 15.3 11.1 13.4 0.8 14.9 11.1 12.1 1.1 14.9 9.1 313 5 313 165 14.4 0 14.6 14.1 06/03/2006 04:10:00 13.1 0.8 14.9 10.7 12.8 0.8 14.9 10.7 11.8 1.1 14.1 8 315 5 309 165 14.2 0 14.4 14.1 06/03/2006 04:20:00 12.3 0.8 14.5 10.3 12 0.7 14.5 9.9 10.8 1 13.3 8 314 5 310 165 14 0.1 14.4 13.3 06/03/2006 04:30:00 12.4 0.8 14.5 9.9 12.1 0.8 13.7 9.5 11.4 1.2 14.1 8 316 5 316 165 14.2 0 14.6 13.5 06/03/2006 04:40:00 12.1 0.8 13.7 9.9 11.8 0.8 13.7 9.1 10.8 1.1 13.3 7.2 315 4 317 165 14.2 0 14.4 13.5 06/03/2006 04:50:00 11.6 0.8 14.9 9.5 11.4 0.8 14.9 9.1 9.7 1.2 12.6 6.8 312 5 309 165 14.4 0 14.6 13.8 06/03/2006 05:00:00 9.8 1 12.2 7.2 9.8 1 12.2 7.2 7.9 1 11.5 5.3 308 6 310 165 14.4 0.1 14.6 13.8 06/03/2006 05:10:00 9.3 1 12.6 6.8 9.3 1 12.6 6.8 7.6 1.1 12.2 4.6 309 6 315 165 14.3 0 14.6 13.8 06/03/2006 05:20:00 8.8 0.7 10.7 6.1 8.7 0.7 11.1 6.1 7 0.8 9.9 4.9 305 7 304 165 14.4 0.1 14.6 13.8 06/03/2006 05:30:00 11.3 0.9 13 8.4 11.4 0.9 13.3 8 8.8 1 11.5 6.1 296 4 297 165 14.5 0.1 14.9 14.1 06/03/2006 05:40:00 12.2 0.6 13.7 10.3 12.3 0.7 13.7 10.3 8.5 0.8 11.5 6.5 299 3 293 165 14.3 0 14.6 13.8 06/03/2006 05:50:00 12.5 0.5 13.7 10.7 12.6 0.6 14.1 10.7 9.2 1.1 12.6 6.8 297 3 297 165 14.3 0 14.6 13.8 06/03/2006 06:00:00 11.5 0.7 13.3 9.1 11.6 0.7 13.3 9.5 9.5 1.3 13.7 6.8 294 4 287 165 14.4 0 14.6 14.1 06/03/2006 06:10:00 10.9 0.9 13.3 8.8 11 0.9 13.3 8.8 8.9 1.5 13 5.7 297 6 307 165 14.7 0 14.9 14.4 06/03/2006 06:20:00 10.7 1.2 13.3 6.8 10.7 1.2 13.3 6.8 8.2 1.2 11.1 5.7 305 5 305 165 15.1 0.1 15.5 14.6 06/03/2006 06:30:00 10.4 1 13.3 8 10.3 1 13.3 8 8.3 1 11.1 6.1 305 5 312 165 15.5 0.1 15.7 14.9 06/03/2006 06:40:00 11.2 1.2 13.7 8.4 11.1 1.2 13.7 8 8.8 1.2 12.2 6.1 305 5 300 165 15.7 0.1 15.7 15.2 06/03/2006 06:50:00 11.4 1 13.3 9.1 11.3 1 13.3 9.1 9.2 1 11.8 6.8 305 4 310 165 15.7 0.1 16 15.2 06/03/2006 07:00:00 11.2 0.8 13.7 9.1 11.1 0.8 13.3 9.1 9 1 11.8 6.5 305 5 311 165 15.6 0.1 16 15.2 06/03/2006 07:10:00 11.7 1.1 14.1 8.8 11.6 1.1 14.1 8.4 9.5 1 12.2 6.8 306 5 309 165 15.8 0 16 15.5 06/03/2006 07:20:00 12.1 0.8 14.5 9.9 12 0.8 14.1 9.9 9.8 0.9 11.8 7.6 306 5 300 165 15.9 0 16.3 15.7 06/03/2006 07:30:00 10.3 1.2 13 6.8 10.2 1.2 13 6.8 8.2 1.3 11.5 4.6 302 6 307 165 16.4 0.3 16.8 16 06/03/2006 07:40:00 8.1 1.3 10.7 3 8.1 1.3 11.1 2.6 6.1 1.5 9.1 1.1 301 10 299 165 17 0.2 17.4 16.8 06/03/2006 07:50:00 6.8 1.2 9.9 3 6.8 1.2 9.9 3.4 5.5 1.1 8.4 2.6 303 12 294 165 17.2 0.1 17.4 16.6 06/03/2006 08:00:00 6.2 1.3 9.1 3 6.2 1.3 9.1 3 5.1 1.1 8 2.3 308 12 293 165 17.3 0 17.4 16.8 06/03/2006 08:10:00 6.9 1.5 10.7 3.4 6.9 1.5 9.9 3.4 5.5 1.2 9.5 2.3 300 15 288 165 17.4 0 17.4 17.1 06/03/2006 08:20:00 8.5 1.1 11.8 4.9 8.5 1.1 11.8 5.3 7.1 1.2 10.3 3.8 293 8 299 165 16.8 0.2 17.4 16.6 06/03/2006 08:30:00 8.1 1.1 11.8 5.3 8.3 1.1 11.5 6.1 7.5 1.3 10.7 4.2 285 10 287 165 16.4 0 16.8 16.3 06/03/2006 08:40:00 9.1 1.3 13 5.7 9.1 1.2 13 6.1 7.4 1.1 11.1 4.9 295 7 290 165 16.4 0 16.8 16.3 06/03/2006 08:50:00 8.4 1.1 11.8 5.3 8.3 1.1 11.5 5.7 7.3 1.3 11.1 3.8 293 11 311 165 16.6 0.1 16.8 16.6 06/03/2006 09:00:00 9.5 1.1 12.2 6.8 9.5 1.1 11.8 6.8 7.6 1.3 11.8 4.9 300 7 310 165 16.6 0 16.8 16.6 06/03/2006 09:10:00 10 0.7 11.5 7.6 10 0.8 11.8 7.6 7.4 0.8 9.5 5.7 299 4 298 165 16.5 0 16.8 16.3 06/03/2006 09:20:00 9.4 0.6 11.8 7.2 9.4 0.7 11.5 7.2 6.9 0.8 9.9 5.3 298 5 300 165 16.5 0 16.8 16.3 06/03/2006 09:30:00 9.8 0.8 11.8 6.8 9.9 0.8 11.5 6.8 7.5 0.9 10.7 4.6 298 6 297 165 16.6 0 16.8 16.6 06/03/2006 09:40:00 10 0.7 11.5 8 10.1 0.7 11.5 8 7.4 0.8 11.1 5.7 301 5 289 165 16.6 0 16.8 16.6 06/03/2006 09:50:00 9.7 0.8 11.8 6.8 9.7 0.8 11.8 6.5 7.5 0.7 9.9 5.3 303 6 299 165 16.6 0 17.1 16.6 06/03/2006 10:00:00 10 0.7 11.8 8.4 10 0.7 11.8 8 7.8 1 10.3 5.7 303 6 296 165 16.9 0 17.1 16.8 06/03/2006 10:10:00 8.9 0.7 10.7 6.8 8.9 0.7 10.7 6.8 7.2 0.9 9.1 4.6 304 5 303 165 17 0.2 17.4 16.8 06/03/2006 10:20:00 8.9 0.9 11.1 6.5 8.9 0.9 11.1 6.1 7.1 0.9 9.5 4.6 303 6 304 165 17 0 17.4 16.8 06/03/2006 10:30:00 8.5 1.1 11.1 4.9 8.5 1.1 10.7 4.6 7.3 1.1 10.7 4.6 307 9 324 165 17 0 17.1 16.8 06/03/2006 10:40:00 8 1.4 10.7 4.6 8 1.4 10.7 4.6 7.4 1.4 10.7 3.4 315 9 310 165 17.5 0 17.7 17.1 06/03/2006 10:50:00 8.2 1.3 11.8 4.9 8.2 1.3 11.5 5.3 7.2 1.4 11.1 3.4 310 10 291 165 17.5 0 18 17.4 06/03/2006 11:00:00 9.3 1.3 12.6 6.1 9.3 1.2 12.6 6.1 7.7 1.3 11.1 4.6 304 9 301 165 17.4 0 17.7 17.4 06/03/2006 11:10:00 11.2 1.3 14.1 7.6 11.1 1.4 14.1 7.6 8.6 1 12.2 5.7 303 8 290 165 17.5 0.1 17.7 17.1 06/03/2006 11:20:00 12.1 1 14.1 9.1 12.1 0.9 14.1 9.1 8.8 1 11.8 6.5 302 5 301 165 17.2 0 17.4 16.8 06/03/2006 11:30:00 11.6 1.3 14.1 6.8 11.5 1.3 13.7 6.8 9.2 1.1 12.2 6.1 305 6 307 165 17.5 0.2 18 17.1 06/03/2006 11:40:00 11 1.2 13.3 8 11 1.2 13.3 7.6 8.5 1.1 12.2 6.1 301 5 305 165 17.5 0 18 17.1 06/03/2006 11:50:00 11 1.2 14.1 8 10.9 1.2 13.7 8 9.3 1.2 12.2 6.1 308 7 307 165 17.8 0 18 17.4 06/03/2006 12:00:00 10.7 1.5 15.6 6.1 10.6 1.4 16.1 6.1 10 1.4 14.1 6.5 316 8 305 165 18.2 0 18.5 17.7 06/03/2006 12:10:00 11.1 1.5 14.9 7.2 10.9 1.5 14.5 7.2 10.1 1.7 14.9 6.5 315 9 315 165 18.2 0.1 18.5 18 06/03/2006 12:20:00 11.1 1.3 15.6 7.6 11 1.3 16.1 7.6 10.5 1.6 14.5 5.3 314 7 312 165 18.1 0.1 18.5 17.7 06/03/2006 12:30:00 10.3 1.2 13.7 7.2 10.3 1.2 13.7 7.2 9 1.6 13 5.3 310 9 309 165 18.1 0.1 18.5 17.7 06/03/2006 12:40:00 10.6 1 12.6 8 10.6 1 12.6 8 8.9 1.3 12.2 6.1 309 6 312 165 18 0 18.2 17.7 06/03/2006 12:50:00 9.5 1.2 12.2 6.5 9.5 1.2 12.2 6.5 7.8 1.3 12.2 4.9 303 6 303 165 18 0 18.2 17.7 06/03/2006 13:00:00 9.4 1.2 12.2 5.3 9.4 1.2 12.2 5.7 7.9 1.2 11.1 4.2 304 9 295 165 18.5 0.1 18.8 18.2 06/03/2006 13:10:00 9.6 1.2 12.6 6.1 9.6 1.2 12.6 5.7 8.2 1.3 11.5 4.2 307 8 307 165 18.6 0.2 19.1 18.2 06/03/2006 13:20:00 11 0.9 13.3 8.8 10.9 0.9 13 8.4 10.2 1.2 13.7 6.8 313 5 318 165 18.7 0.2 19.1 18.5 06/03/2006 13:30:00 9.9 1.1 12.2 7.2 9.8 1.1 12.2 7.2 9.1 1.2 12.2 6.1 313 6 300 165 18.7 0.2 19.1 18.5 06/03/2006 13:40:00 10.5 1.1 13.3 6.8 10.3 1 13 7.2 10 1.2 13.3 6.8 315 5 307 165 18.9 0 19.4 18.5 06/03/2006 13:50:00 10.9 1.4 13.7 7.2 10.8 1.4 13.7 7.2 9.8 1.5 13.3 5.7 307 11 295 165 19.1 0.1 19.7 18.8 06/03/2006 14:00:00 10.7 1.1 13 7.2 10.7 1.1 13.3 7.6 8.9 1.2 11.8 6.1 304 8 302 165 18.7 0 19.1 18.5 06/03/2006 14:10:00 10.7 1.5 13.7 6.8 10.7 1.4 13.7 6.8 8.8 1.4 12.6 5.3 301 8 304 165 18.9 0.1 19.4 18.5 06/03/2006 14:20:00 12.1 1 14.9 8.8 12.1 1 14.9 8.4 9.3 1.3 13.7 6.5 301 6 295 165 18.3 0 18.8 18 06/03/2006 14:30:00 11.9 1.2 15.3 8.4 11.8 1.2 14.9 8.4 9.4 1.3 13 6.8 303 8 311 165 18.3 0.1 18.8 18 06/03/2006 14:40:00 14.1 1.5 16.8 9.9 13.9 1.5 16.8 9.9 12.8 1.9 17.2 8 313 6 316 165 18.3 0.2 18.8 18 06/03/2006 14:50:00 12.7 1.2 16.1 9.1 12.6 1.2 15.6 9.1 11.9 1.6 16.1 7.2 316 10 332 165 18.1 0.2 18.5 17.7 06/03/2006 15:00:00 13.9 1.2 16.8 11.1 13.7 1.2 16.8 11.1 13 1.5 16.1 8.4 316 7 306 165 18.2 0 18.5 18 06/03/2006 15:10:00 11.7 1 14.5 8.8 11.5 1 14.1 8.4 10.6 1.4 13.3 5.7 317 8 320 165 18.3 0.3 18.8 17.7 06/03/2006 15:20:00 12.7 1.1 14.9 8.8 12.6 1.1 14.9 8.8 12.2 1.2 14.9 8.8 318 8 323 165 18.4 0.3 18.8 17.7 06/03/2006 15:30:00 12.7 1 15.3 9.5 12.7 1 15.3 9.9 10 1.5 14.1 6.8 306 6 310 165 17.9 0 18.2 17.7 06/03/2006 15:40:00 11.7 1.2 14.5 8.4 11.6 1.2 14.1 8.4 10.5 1.5 14.1 6.1 312 6 310 165 18.1 0 18.5 18 06/03/2006 15:50:00 10.4 1.2 12.6 6.5 10.3 1.1 12.6 7.2 9.3 1.4 12.6 5.7 313 7 310 165 18.4 0.1 19.1 18 06/03/2006 16:00:00 7.8 1.5 11.5 3.8 7.8 1.5 11.1 3.4 6.9 1.9 11.5 1.5 314 13 327 165 19.2 0.3 20 18.8 06/03/2006 16:10:00 5.1 1.9 9.1 0.7 5.2 2 9.5 0.4 4 1.3 7.2 0.4 295 39 331 165 19 0.1 19.7 18.5 06/03/2006 16:20:00 6.9 1.3 9.9 3 6.9 1.3 10.3 2.6 5.2 1.5 8.8 1.1 309 15 316 165 18.8 0.2 19.4 18.5 06/03/2006 16:30:00 6.3 1.8 9.9 0.4 6.3 2 9.9 0.7 4.9 1.7 9.5 0.7 306 35 315 165 19.3 0 19.7 19.1 06/03/2006 16:40:00 7.5 1.1 11.1 4.9 7.5 1.1 11.1 4.9 6.1 1.2 9.9 2.6 308 10 308 165 19.4 0 19.7 19.1 06/03/2006 16:50:00 7.6 1.1 10.3 4.9 7.6 1 10.7 4.9 6.9 1.2 10.7 4.2 309 13 315 165 18.9 0 19.4 18.5 06/03/2006 17:00:00 7.1 1.7 11.8 3.4 7.2 1.6 11.8 3.4 6.1 1.5 10.7 3 300 12 304 165 18.6 0 18.8 18.5 06/03/2006 17:10:00 6.7 1.6 11.1 3 6.7 1.6 11.5 3 5.5 1.5 9.1 2.6 298 12 299 165 18.7 0 19.1 18.2 06/03/2006 17:20:00 6 1.3 9.1 3 6.1 1.3 9.5 3.4 4.8 1.2 8.4 1.5 297 14 308 165 18.4 0.4 19.1 17.7 06/03/2006 17:30:00 7.5 1.3 9.9 4.2 7.5 1.3 10.3 4.2 5.9 1.3 9.1 2.3 302 10 300 165 17.6 0.1 18 17.1 06/03/2006 17:40:00 6.5 1.2 9.5 3.8 6.5 1.2 9.9 3.4 5.4 1.2 8.8 2.6 304 12 312 165 17.6 0.5 18.2 16.8 06/03/2006 17:50:00 7.6 1 9.9 5.3 7.6 1 10.3 4.6 6.2 1.3 10.3 3 305 9 314 165 17.4 0.2 18 16.8 06/03/2006 18:00:00 6.5 1.2 9.5 3.8 6.5 1.2 9.5 3.4 5.3 1.2 8.4 2.6 301 10 303 165 17.5 0.1 18 16.8 06/03/2006 18:10:00 6.9 1.1 9.5 3.8 6.9 1.1 9.5 3.8 5.4 1.3 8.8 0.7 300 8 295 165 17.7 0.3 18.2 17.1 06/03/2006 18:20:00 7.4 1 10.3 4.2 7.4 0.9 10.3 4.9 6.1 1 8.8 3.4 299 7 302 165 17.5 0.1 17.7 17.1 06/03/2006 18:30:00 7.8 1.2 10.3 4.2 7.7 1.2 10.3 4.2 6.3 1 9.5 3.8 297 7 290 165 17.2 0 17.4 16.8 06/03/2006 18:40:00 6.9 1 9.5 3.8 6.9 1 9.5 4.2 5.6 1 8.4 3 297 9 305 165 17.1 0 17.4 16.8 06/03/2006 18:50:00 7.1 1.4 11.1 4.2 7.2 1.4 10.7 4.6 6.1 1.3 9.1 3.8 295 11 309 165 16.8 0.1 17.1 16.6 06/03/2006 19:00:00 7.1 1.5 10.3 3 7.2 1.5 10.3 3.4 6.1 1.3 9.1 3 295 11 307 165 16.7 0 16.8 16.6 06/03/2006 19:10:00 7.3 1.1 9.9 4.2 7.3 1.1 9.9 4.2 6.1 1.1 9.5 3.4 295 10 283 165 16.5 0 16.8 16.3 06/03/2006 19:20:00 7.3 1.4 11.5 3.8 7.2 1.3 11.1 4.2 5.9 1.3 8.8 2.3 296 10 290 165 16.1 0 16.3 16 06/03/2006 19:30:00 7.4 1.5 11.8 4.2 7.5 1.5 11.1 3.8 6.7 1.7 11.1 2.6 291 9 279 165 15.9 0 16.3 15.5 06/03/2006 19:40:00 8.5 1.5 12.2 4.9 8.5 1.4 11.8 5.3 7.3 1.3 10.3 3.8 288 10 296 165 15.3 0.1 15.7 15.2 06/03/2006 19:50:00 9.8 1.2 13 6.8 9.8 1.1 13 7.2 7.8 1.2 11.1 4.2 297 7 293 165 15.1 0 15.5 14.6 06/03/2006 20:00:00 12.4 0.9 14.9 9.5 12.3 0.9 14.9 9.9 10.4 1.6 14.1 6.5 308 7 301 165 14.8 0 15.2 14.6 06/03/2006 20:10:00 13 0.6 14.9 11.1 12.8 0.7 14.5 11.1 11.6 1.1 14.5 8.4 310 4 311 165 14.6 0 14.9 14.6 06/03/2006 20:20:00 12 1 14.1 9.5 11.9 1 14.1 9.5 10.3 1.4 13.3 6.5 307 5 298 165 14.4 0 14.6 14.4 06/03/2006 20:30:00 10.3 1 13 7.6 10.3 1 13 8 8.1 1.2 11.8 5.3 303 6 296 165 14.3 0 14.6 14.1 06/03/2006 20:40:00 9.4 0.7 11.5 8 9.4 0.7 11.5 7.6 7.4 1 10.7 5.3 304 6 300 165 14 0 14.4 13.8 06/03/2006 20:50:00 7.7 1 9.9 5.3 7.6 1 9.9 5.3 6.3 1.1 9.1 3.8 304 9 301 165 13.8 0 14.1 13.3 06/03/2006 21:00:00 8.8 1.1 11.5 6.1 8.6 1.1 11.1 6.1 8.3 1.3 11.8 4.9 320 8 324 165 13.5 0.1 13.8 13 06/03/2006 21:10:00 8.2 0.8 10.7 6.1 8.1 0.8 11.1 6.1 7.6 0.9 9.9 5.3 317 9 322 165 13.1 0.2 13.5 12.5 06/03/2006 21:20:00 7.6 1.3 11.1 4.9 7.6 1.3 10.7 4.9 6.6 1.3 11.1 3.8 316 9 310 165 12.5 0.1 13.3 11.9 06/03/2006 21:30:00 7.2 1 9.5 4.2 7.1 1 9.9 2.6 6.3 1.1 10.3 2.3 314 10 302 165 12.3 0 12.7 11.7 06/03/2006 21:40:00 8 1.1 10.7 4.2 8.1 1.2 11.1 4.6 6.8 1.3 10.7 3 313 11 316 165 12.2 0 12.5 11.9 06/03/2006 21:50:00 8.9 1.5 12.2 4.2 8.9 1.5 12.6 4.6 7.1 1.7 12.2 1.1 307 10 302 165 12.3 0 12.5 11.9 06/03/2006 22:00:00 9.8 1.2 14.1 6.8 9.8 1.2 14.5 6.1 8.1 1.3 12.2 4.2 309 9 297 165 12.3 0 12.5 12.2 06/03/2006 22:10:00 9.6 1.2 13 5.3 9.6 1.2 12.6 5.3 7.9 1.5 12.6 3 309 8 316 165 12.3 0 12.5 12.2 06/03/2006 22:20:00 8.6 1.3 13 3.8 8.6 1.3 13 3.8 7.1 1.7 12.2 1.1 309 8 307 165 12.3 0 12.5 11.9 06/03/2006 22:30:00 8.9 1 11.8 6.5 8.9 0.9 11.5 6.5 7 0.9 9.9 5.3 304 7 302 165 12.4 0 12.7 12.2 06/03/2006 22:40:00 9.2 0.9 12.2 6.8 9.1 0.9 11.5 6.8 7.8 0.9 10.3 5.7 309 9 293 165 12.2 0 12.5 11.9 06/03/2006 22:50:00 7.4 1.4 10.7 4.2 7.3 1.4 10.3 4.2 6.6 1.3 9.9 3.4 312 10 310 165 12.1 0 12.5 11.7 06/03/2006 23:00:00 7.4 1.1 11.8 4.9 7.3 1.2 11.1 4.2 7.2 1.1 11.1 3.8 329 14 323 165 12.1 0.2 12.5 11.7 06/03/2006 23:10:00 8.2 1 11.5 5.7 8.1 1.2 11.8 4.9 7.5 1.2 10.7 3 330 17 342 165 11.9 0 12.2 11.7 06/03/2006 23:20:00 8.6 1.3 13 5.7 8.6 1.3 12.6 5.7 6.8 1.5 11.8 3 307 9 301 165 11.7 0 11.9 11.4 06/03/2006 23:30:00 7.8 1.6 11.8 3 7.8 1.7 11.8 2.3 6.3 1.7 10.7 1.1 310 11 305 165 11.5 0 11.7 11.4 06/03/2006 23:40:00 7.1 1.1 9.9 4.2 7 1.2 10.7 4.2 6 1.4 9.1 2.6 315 19 313 165 11.5 0 11.7 11.1 06/03/2006 23:50:00 5.4 1.7 9.5 1.9 5.2 1.7 9.9 1.5 4.2 2 10.7 0.4 330 26 344 165 11.3 0 11.7 11.1 06/04/2006 00:00:00 5.3 1.1 8.4 2.6 5.2 1.2 9.1 1.9 4.9 1 8.4 2.3 327 15 356 165 11.5 0 11.7 11.4 06/04/2006 00:10:00 6.8 1.2 10.3 4.2 6.5 1.2 9.9 3 6.2 1.2 9.9 3 338 15 11 165 11.5 0 11.9 11.4 06/04/2006 00:20:00 6.8 1.4 10.7 3.8 6.1 1.3 9.9 3 6.5 1.3 10.3 3.4 347 13 354 165 11.7 0 11.9 11.4 06/04/2006 00:30:00 6 1.4 9.9 2.3 5.6 1.3 10.3 2.3 5.5 1.3 9.5 2.6 340 18 341 165 11.5 0.1 11.7 11.1 06/04/2006 00:40:00 4.9 0.9 7.6 2.6 4.8 0.9 7.6 2.3 4.2 0.8 6.5 2.3 316 16 336 165 11.1 0.2 11.7 10.9 06/04/2006 00:50:00 5.8 1 8.4 3 5.7 1 8.4 2.6 4.4 1.1 7.2 1.9 309 15 314 165 10.6 0.1 10.9 10.3 06/04/2006 01:00:00 6 1.2 10.3 2.6 5.8 1.3 9.9 2.3 5.3 1.1 9.5 2.6 324 15 305 165 10.7 0.1 11.1 10.3 06/04/2006 01:10:00 7.8 1.2 10.7 4.9 7.7 1.2 10.7 4.9 6.8 1.1 9.9 3.8 312 12 316 165 11.1 0 11.4 10.9 06/04/2006 01:20:00 8.3 1.3 12.2 4.6 8.3 1.3 11.8 4.6 7.1 1.3 10.3 3.4 311 11 308 165 11 0 11.4 10.9 06/04/2006 01:30:00 8.2 1.3 12.2 4.6 8.1 1.3 11.8 4.2 7 1.3 10.3 3.4 312 12 302 165 10.9 0.1 11.1 10.6 06/04/2006 01:40:00 8.7 1 11.5 6.1 8.5 1 11.5 5.7 7.5 1.2 11.1 3.4 310 7 303 165 10.7 0.1 10.9 10.3 06/04/2006 01:50:00 9.1 0.8 11.8 6.5 9 0.8 11.5 6.8 7.8 0.9 11.1 5.7 310 4 318 165 10.6 0.2 10.9 10.3 06/04/2006 02:00:00 9.6 0.8 13.3 7.6 9.5 0.8 13 7.2 8.2 1.1 11.8 4.9 310 5 316 165 10.5 0.2 10.9 10.3 06/04/2006 02:10:00 10.4 0.7 11.8 8 10.2 0.7 12.2 8.4 9.2 0.8 11.8 6.8 311 4 307 165 10.5 0.2 10.9 10.3 06/04/2006 02:20:00 9.8 0.6 12.2 8.4 9.7 0.6 11.8 8.4 9.3 0.8 11.5 6.8 315 4 326 165 10.3 0.1 10.6 9.8 06/04/2006 02:30:00 9.5 0.7 11.8 7.2 9.4 0.7 11.8 6.8 8.5 0.9 11.1 6.1 312 5 313 165 10.3 0.1 10.9 9.8 06/04/2006 02:40:00 10.7 1 13.7 8.8 10.5 0.9 13.7 8.4 9.3 1 12.6 5.7 311 5 300 165 10.4 0.2 10.9 9.8 06/04/2006 02:50:00 9.9 0.9 13 7.6 9.8 0.9 12.6 7.2 8.3 1.2 11.8 5.3 310 5 311 165 10.4 0.1 10.9 9.8 06/04/2006 03:00:00 9.3 0.8 11.5 7.2 9.2 0.8 11.5 7.2 7.4 1 11.1 4.9 307 5 307 165 10.1 0.2 10.3 9.6 06/04/2006 03:10:00 8.8 0.7 10.7 6.5 8.7 0.7 10.3 6.1 6.7 0.7 8.8 4.6 302 5 309 165 9.8 0.2 10.6 9 06/04/2006 03:20:00 9.7 1.2 14.5 7.2 9.6 1.2 13.7 7.2 8 1.2 11.5 5.3 309 10 288 165 10.1 0.5 11.1 9.3 06/04/2006 03:30:00 8.8 1.3 13.3 5.7 8.7 1.3 13.3 5.7 7.4 1.1 11.1 4.9 310 9 314 165 10.6 0.2 11.1 10.3 06/04/2006 03:40:00 9.6 1 11.8 6.1 9.4 1 11.5 6.1 8.2 1.1 11.1 5.3 311 10 325 165 10.2 0.1 10.6 9.8 06/04/2006 03:50:00 11.9 1.5 16.4 8 11.7 1.5 16.1 8.4 10.5 1.7 16.1 6.8 311 10 300 165 10.9 0.4 11.4 9.8 06/04/2006 04:00:00 11.6 0.9 14.5 9.5 11.4 0.8 14.1 9.5 9.7 1.1 12.6 6.8 307 5 311 165 10.7 0.3 11.4 10.1 06/04/2006 04:10:00 12.2 1.1 15.3 9.5 12.1 1 15.3 9.5 10 1.4 14.1 7.2 308 7 297 165 10.6 0.2 10.9 10.1 06/04/2006 04:20:00 13.2 1.6 17.6 9.1 13 1.6 17.9 8.8 11.1 1.9 15.6 6.8 309 7 307 165 10.7 0.2 11.1 10.3 06/04/2006 04:30:00 12.5 1.4 19.9 10.3 12.4 1.3 19.5 9.9 10.5 1.7 16.1 7.6 309 8 302 165 10.6 0.2 11.1 10.3 06/04/2006 04:40:00 13.2 1.2 17.6 10.3 13 1.2 17.2 10.3 11.1 1.5 16.8 8.4 309 7 302 165 10.6 0.2 11.1 10.1 06/04/2006 04:50:00 12.4 1.2 16.1 9.1 12.2 1.2 16.8 9.5 11.5 1.1 14.1 7.2 315 7 309 165 10.5 0.3 11.1 9.8 06/04/2006 05:00:00 11.1 1.2 14.5 8.4 11 1.1 14.1 8.8 10.7 1.2 15.3 8 327 12 321 165 10.8 0.2 11.1 10.3 06/04/2006 05:10:00 11.3 1.6 16.1 7.6 11.2 1.7 16.4 7.6 10.3 1.4 14.5 6.8 321 15 305 165 10.9 0.2 11.4 10.3 06/04/2006 05:20:00 13.1 1.2 16.4 8.8 12.9 1.2 16.1 8.4 10.2 1.2 13.3 6.8 305 5 307 165 11.1 0.1 11.4 10.9 06/04/2006 05:30:00 13.2 1.9 17.6 8.4 13.1 1.9 17.2 8.8 10.4 1.7 17.6 6.8 303 7 301 165 11 0 11.4 10.9 06/04/2006 05:40:00 12.2 1.9 17.6 7.2 12 1.9 17.6 6.5 9.6 1.4 13.7 5.7 304 9 293 165 11.1 0.2 11.4 10.9 06/04/2006 05:50:00 9.7 1.4 12.6 6.8 9.6 1.3 13.7 6.5 8.8 1.3 12.2 4.9 317 12 298 165 11.5 0.2 11.9 10.9 06/04/2006 06:00:00 9.6 1.3 12.6 6.1 9.4 1.3 12.2 5.7 8.8 1.2 11.8 4.9 321 12 316 165 11.7 0.1 12.2 11.7 06/04/2006 06:10:00 9.3 1.4 13.7 6.1 9 1.3 13.7 5.7 8.7 1.3 12.2 5.3 329 12 346 165 12.1 0 12.5 11.9 06/04/2006 06:20:00 7.1 2.2 12.6 2.6 6.9 2.2 12.6 2.3 6.8 2.1 12.2 3 334 16 310 165 12.5 0.1 12.7 11.9 06/04/2006 06:30:00 6.1 1.8 11.1 2.3 6 1.7 11.1 2.3 5.5 1.7 10.3 1.9 319 17 348 165 12.7 0 12.7 12.2 06/04/2006 06:40:00 7.2 1.8 11.8 3.4 7.1 1.8 11.8 3.8 5.9 1.8 11.8 2.6 301 16 285 165 12.4 0.2 12.7 11.9 06/04/2006 06:50:00 11.4 1.5 16.1 7.2 11.5 1.5 16.1 7.2 10.4 1.7 14.9 5.7 286 7 300 165 11.3 0.2 11.9 10.9 06/04/2006 07:00:00 10.3 1.2 13.7 7.2 10.3 1.2 13.7 7.2 8.8 1.6 13.3 4.9 294 7 282 165 11.2 0.1 11.7 10.9 06/04/2006 07:10:00 10.1 1.1 13 6.1 10.1 1.1 12.6 6.1 8.5 1.5 11.8 4.9 293 7 290 165 11.4 0 11.7 10.9 06/04/2006 07:20:00 10.7 1.1 13.3 7.6 10.7 1.1 13.3 7.6 9 1.4 12.6 5.3 294 6 292 165 11.3 0.1 11.7 10.9 06/04/2006 07:30:00 9.6 1.3 13.3 6.5 9.6 1.3 13.3 6.5 7.9 1.5 11.8 4.6 299 9 289 165 11.7 0.1 11.9 11.1 06/04/2006 07:40:00 11.4 1.1 13.7 8.4 11.4 1.1 14.1 8.4 9.8 1.5 13 6.1 293 6 291 165 11.7 0.1 11.9 11.4 06/04/2006 07:50:00 12.1 1.2 15.6 9.1 12.2 1.2 15.6 7.6 10.3 1.7 14.5 6.5 294 6 289 165 11.6 0 11.9 11.1 06/04/2006 08:00:00 11.2 1.8 15.6 6.8 11.2 1.7 15.6 7.6 9.8 2.2 15.3 5.3 293 8 294 165 11.6 0.2 11.9 11.1 06/04/2006 08:10:00 11.6 1.4 15.3 7.6 11.5 1.5 15.6 8 9.6 1.7 14.9 5.7 296 8 292 165 12.1 0 12.5 11.9 06/04/2006 08:20:00 10.6 1.2 13.3 7.6 10.5 1.2 13.3 7.6 8.4 1.3 12.6 5.3 302 7 300 165 12.5 0 12.7 12.2 06/04/2006 08:30:00 11.8 1.6 18.3 8 11.6 1.5 17.9 7.6 9.3 1.3 15.6 5.7 301 6 304 165 12.9 0 13 12.7 06/04/2006 08:40:00 12.6 1.3 15.3 9.1 12.4 1.2 15.3 8.8 9.5 1.3 13.7 6.5 299 5 304 165 12.7 0 13 12.2 06/04/2006 08:50:00 11.5 1.3 16.1 8 11.4 1.2 15.6 8 9.1 1.3 13.7 6.1 299 6 297 165 12.7 0 13 12.2 06/04/2006 09:00:00 9.7 1.4 13.3 6.1 9.7 1.4 13 5.7 8 1.5 11.5 4.2 297 10 278 165 13.3 0.2 13.8 12.5 06/04/2006 09:10:00 7.7 1.7 12.2 3.8 7.4 1.9 11.8 3.4 7.3 1.8 11.8 3.4 333 17 335 165 14.2 0.3 15.2 13.3 06/04/2006 09:20:00 8.8 2.2 14.1 4.6 8.3 2 13.3 3.4 8 2.5 14.1 3 332 21 359 165 14.8 0 15.2 14.6 06/04/2006 09:30:00 8 1.5 12.6 4.2 7.5 1.5 13.7 4.2 7.3 1.7 12.6 3.8 328 22 350 165 14.9 0 15.2 14.6 06/04/2006 09:40:00 8.5 1.1 11.8 5.7 8.5 1 11.8 6.1 7.4 1.3 10.7 4.6 300 15 317 165 14.4 0.1 15.2 14.1 06/04/2006 09:50:00 7.8 1.6 13 4.2 7.8 1.5 12.2 3.8 7 1.3 10.7 4.2 304 17 289 165 14.7 0 15.2 14.4 06/04/2006 10:00:00 8.2 1.5 13.3 5.3 8.2 1.5 13 5.3 6.7 1.2 11.5 4.2 298 10 302 165 14.3 0 14.6 14.1 06/04/2006 10:10:00 7.6 1.3 12.2 4.2 7.6 1.3 11.8 4.2 6.8 1.1 10.3 3.8 306 17 302 165 15 0.2 15.5 14.6 06/04/2006 10:20:00 7.3 1.2 10.7 4.6 7 1.4 10.3 3 7 1.3 10.3 3.8 331 18 308 165 15.7 0.2 16.3 15.2 06/04/2006 10:30:00 6.6 1.2 9.9 3.4 6.3 1.3 9.5 2.6 6.3 1.3 9.9 3.4 324 28 360 165 16.1 0.1 16.6 15.7 06/04/2006 10:40:00 6.6 0.9 9.1 4.9 6.5 1 9.1 2.6 6 1.1 8.8 3.4 317 21 320 165 16.1 0.4 16.8 15.5 06/04/2006 10:50:00 6.5 1.1 10.3 2.6 6.5 1.1 10.3 3.8 5.6 1.2 8.8 1.5 298 17 290 165 16.4 0.5 16.8 15.7 06/04/2006 11:00:00 7 1.1 10.7 3.8 7 1.1 10.7 3.8 6.2 1.2 9.9 3.4 307 12 284 165 15.9 0.4 16.6 15.2 06/04/2006 11:10:00 8 0.8 10.3 6.1 8 0.8 10.3 5.7 7.1 1 9.9 4.9 310 9 313 165 15.1 0.3 15.7 14.6 06/04/2006 11:20:00 8.9 1 11.5 6.1 8.9 1 11.5 6.1 7.8 1 9.9 4.9 312 12 312 165 15.5 0.2 16 15.2 06/04/2006 11:30:00 8.3 1.1 11.1 4.9 8.3 1.1 11.1 5.3 7.3 1.1 10.3 4.6 310 8 307 165 15.5 0.2 16 15.2 06/04/2006 11:40:00 8.5 1.2 11.5 4.6 8.5 1.2 11.1 4.6 6.9 1.1 9.9 4.6 304 8 301 165 15.5 0.2 16 15.2 06/04/2006 11:50:00 7.4 1.5 11.1 4.2 7.4 1.5 11.5 4.2 6.5 1.7 11.1 3.4 300 14 314 165 15.3 0.1 16 14.9 06/04/2006 12:00:00 6.8 1.5 10.3 3.8 6.8 1.5 10.3 3.8 6.3 1.7 10.7 3 306 18 322 165 16 0 16.3 15.7 06/04/2006 12:10:00 7.6 1.5 10.7 4.2 7.6 1.5 10.7 3.8 6.5 1.3 10.3 3.4 299 12 296 165 16.4 0.4 17.1 15.7 06/04/2006 12:20:00 7.7 1 10.3 5.3 7.7 1 10.3 5.7 6.9 1.2 11.1 3.4 307 13 306 165 16.1 0.2 16.6 15.7 06/04/2006 12:30:00 5.2 0.8 7.6 3.8 4.8 0.9 7.2 2.6 4.9 0.9 6.8 2.6 339 21 334 165 17.5 0.9 19.1 16 06/04/2006 12:40:00 5.1 1.2 7.6 2.6 4.8 1.2 8 1.9 4.6 1.2 7.6 1.9 325 35 286 165 18.1 0.5 19.1 16.8 06/04/2006 12:50:00 4.8 1.2 7.6 1.5 4.8 1.2 7.2 1.5 4.5 1.2 8 1.5 302 21 279 165 17 0.2 17.4 16.8 06/04/2006 13:00:00 5.9 1.2 8.4 1.9 5.7 1.3 8.4 1.9 5.4 1.1 8.4 2.6 335 21 300 165 17.4 0.4 18.2 16.8 06/04/2006 13:10:00 5.6 1.1 8.4 3 5.6 1.1 8 3 5.3 1.2 8 3 327 18 344 165 18.2 0.1 18.5 17.7 06/04/2006 13:20:00 6.5 1.3 11.1 3 6.5 1.4 10.7 2.6 5.9 1.5 9.9 3 311 14 304 165 17.1 0.6 18.2 16.3 06/04/2006 13:30:00 6.9 1.2 9.9 4.2 6.8 1.2 9.9 4.2 6.3 1.3 10.3 3.4 316 18 279 165 16.9 0.4 18 16.3 06/04/2006 13:40:00 7.6 0.9 9.5 5.3 7.5 0.9 9.5 5.3 7 1.2 10.7 3.8 313 9 332 165 17.3 0.4 18 16.6 06/04/2006 13:50:00 7.2 1.3 10.3 4.2 7.2 1.3 9.9 4.2 6.7 1.3 10.3 3.8 314 10 315 165 17.3 0.1 18 17.1 06/04/2006 14:00:00 7.5 1.2 11.1 4.2 7.4 1.3 10.7 3 7.2 1.3 10.7 4.2 329 16 340 165 16.8 0.3 17.4 16.6 06/04/2006 14:10:00 7.3 1.1 9.9 3.8 6.8 1.5 10.3 3.4 7.1 1.3 10.7 3.4 344 15 357 165 17.9 0.3 18.8 17.1 06/04/2006 14:20:00 7.7 1 10.7 5.3 6.7 1.3 10.7 3 7.5 1 10.3 4.2 350 10 0 165 18 0 18.5 17.7 06/04/2006 14:30:00 7.2 0.8 10.3 4.9 6.4 1.2 10.7 3.4 7 0.9 9.9 4.9 345 15 344 165 18.2 0.1 18.8 18 06/04/2006 14:40:00 6.6 1.5 10.7 3 6.2 1.4 9.1 3 6.4 1.5 9.5 2.6 339 13 355 165 18.2 0.2 18.8 17.7 06/04/2006 14:50:00 6.9 0.9 9.5 4.6 6.7 1 9.1 4.2 6.5 1 8.8 3.8 337 15 351 165 18.7 0.1 19.4 18.2 06/04/2006 15:00:00 6.6 1.3 10.7 3.4 5.7 1.7 9.5 2.3 6.4 1.4 11.5 2.3 354 12 8 165 18.3 0 18.8 18 06/04/2006 15:10:00 6.4 1 9.1 3.8 6 1.2 9.1 3 6 1 8.8 3.8 329 23 308 165 18 0.1 18.2 17.4 06/04/2006 15:20:00 5.8 0.8 8 4.2 5.7 0.8 8 3.4 5.4 0.8 8.4 3 319 18 317 165 18 0.2 18.5 17.4 06/04/2006 15:30:00 5.8 0.9 8.4 2.6 5.4 1 8.4 2.6 5.5 1 7.6 2.6 326 22 317 165 18.6 0.2 19.4 18.2 06/04/2006 15:40:00 5.5 1.2 8.8 3 4.8 1.5 8.8 2.3 5.2 1.3 8.4 2.6 348 17 336 165 18.2 0.3 19.1 17.7 06/04/2006 15:50:00 4.1 1.3 7.6 0.7 3.6 1.3 7.6 0.4 3.5 1.5 6.8 0.4 338 35 344 165 18.1 0.4 19.4 17.7 06/04/2006 16:00:00 3.1 1.3 6.1 0.4 3.2 1.3 6.1 0.4 2.6 1.2 6.1 0.4 307 43 320 165 18.6 0.3 19.1 17.7 06/04/2006 16:10:00 5.6 1.5 11.1 2.6 5.6 1.5 11.1 2.6 5.1 1.6 11.1 2.3 302 18 293 165 17.1 0.4 18 16.6 06/04/2006 16:20:00 6.4 0.9 8.8 3.4 5.9 1.2 8.4 3 6 1.1 8 1.9 350 8 4 165 18.4 0.2 18.8 17.4 06/04/2006 16:30:00 7.3 1.1 9.9 4.6 6.6 1.6 10.3 3 7.2 1 9.5 4.9 348 9 358 165 18.2 0 18.5 18 06/04/2006 16:40:00 8.3 1 10.3 5.7 8.1 1.4 10.7 3 8.2 1.1 10.7 5.3 348 6 342 165 17.8 0 18 17.4 06/04/2006 16:50:00 7.5 0.8 9.1 4.9 7.2 1.3 9.5 3 7.4 0.8 9.1 4.9 346 8 341 165 17.4 0.1 17.7 17.1 06/04/2006 17:00:00 6.5 0.8 8.8 4.2 6.4 0.9 9.1 3.8 6.3 0.9 9.1 4.6 340 7 339 165 17.8 0.2 18.2 17.1 06/04/2006 17:10:00 6.4 0.9 8.4 4.2 5.8 1.3 8.8 3 6.3 1 8.4 3.8 349 8 349 165 17.6 0 18 17.4 06/04/2006 17:20:00 6.5 0.7 8.4 4.9 6.1 1.1 8.4 3.4 6.5 0.8 8.4 4.2 344 10 343 165 17.5 0 17.7 17.1 06/04/2006 17:30:00 7.1 1.1 9.5 4.6 7 1.1 9.1 3.8 6.8 1 8.8 4.2 339 8 334 165 17.1 0 17.4 16.8 06/04/2006 17:40:00 6.8 0.6 8.4 4.9 6.8 0.6 8.4 4.9 6.7 0.6 8.4 3.8 340 6 346 165 17 0.1 17.1 16.8 06/04/2006 17:50:00 6.6 0.7 8.4 4.9 6.5 0.8 8.4 3.8 6.5 0.8 8.8 4.2 338 10 354 165 16.8 0 17.1 16.6 06/04/2006 18:00:00 6.9 0.9 9.1 4.6 6.8 1 9.5 4.6 6.9 0.9 9.5 4.6 337 9 338 165 16.8 0 17.1 16.6 06/04/2006 18:10:00 6.4 0.8 8.8 4.2 6.3 0.9 9.1 3.8 6.3 0.8 9.1 4.2 344 7 338 165 16.6 0 16.8 16.6 06/04/2006 18:20:00 6.2 1 9.5 3.8 5.6 1.1 9.1 2.6 5.9 1 9.5 3.4 343 15 339 165 16.6 0 16.8 16.3 06/04/2006 18:30:00 5.9 0.9 8.8 3.4 5.5 1.2 9.1 2.6 5.9 1 8 3.4 347 11 341 165 16 0.2 16.6 15.7 06/04/2006 18:40:00 5.5 0.8 8 3.4 5.3 0.9 8 3 5.4 0.8 7.6 3.8 340 11 318 165 16.3 0.1 16.6 16 06/04/2006 18:50:00 5.9 0.8 8 3.8 5.9 0.9 8.4 4.2 5.9 0.8 8 3.8 339 11 343 165 16.1 0 16.3 16 06/04/2006 19:00:00 5 0.8 6.8 3.4 4.8 1 6.8 2.3 4.9 0.8 6.8 3 343 10 338 165 16.1 0 16.3 15.7 06/04/2006 19:10:00 5.5 0.6 7.6 4.2 5.3 0.7 7.6 3.4 5.4 0.7 7.2 3.4 339 11 352 165 16 0 16.3 15.7 06/04/2006 19:20:00 5.1 0.6 7.2 3 5 0.8 7.6 3 5.1 0.6 7.2 3.4 344 7 339 165 15.6 0 16 15.2 06/04/2006 19:30:00 4.5 0.7 6.1 2.6 4.4 0.8 5.7 2.3 4.6 0.7 6.1 2.6 343 9 338 165 15.5 0 15.7 14.9 06/04/2006 19:40:00 4.5 0.6 5.7 3 4.5 0.6 5.7 2.6 4.5 0.6 6.1 2.6 337 8 347 165 15.3 0.1 15.7 14.9 06/04/2006 19:50:00 4.8 0.8 6.8 2.6 4.8 0.8 6.8 2.6 4.8 0.8 6.5 2.6 335 7 329 165 15.1 0 15.5 14.6 06/04/2006 20:00:00 4.4 0.7 6.1 2.3 4.3 0.8 6.5 1.9 4.4 0.7 6.1 2.6 338 10 332 165 14.7 0 14.9 14.6 06/04/2006 20:10:00 4.6 0.5 6.1 3 4.6 0.6 6.1 3 4.5 0.5 6.1 3 333 8 333 165 14.6 0 14.6 14.4 06/04/2006 20:20:00 4.7 0.5 6.1 3.4 4.6 0.5 6.1 3 4.5 0.5 5.7 3 335 8 344 165 14.3 0 14.6 14.1 06/04/2006 20:30:00 4.1 0.5 5.3 3 4 0.6 5.3 1.9 4 0.5 5.3 3 341 7 333 165 13.7 0.2 14.4 13.3 06/04/2006 20:40:00 4.2 0.6 6.1 2.6 3.9 0.8 5.7 1.5 4 0.6 5.7 2.6 345 8 334 165 13.3 0 13.5 13 06/04/2006 20:50:00 2.9 0.4 3.8 1.9 2.4 0.5 3.8 1.1 2.8 0.4 3.8 1.9 350 11 358 165 13.1 0.1 13.8 12.5 06/04/2006 21:00:00 2.6 0.3 3.4 1.9 2.4 0.5 3.4 1.1 2.5 0.3 3.4 1.9 343 6 334 165 12.7 0.2 13.3 11.9 06/04/2006 21:10:00 3.4 0.4 4.6 2.6 3.4 0.5 4.6 2.3 3.3 0.4 4.6 2.6 338 7 326 165 11.7 0.3 12.5 10.9 06/04/2006 21:20:00 3.9 0.4 5.3 3 3.6 0.5 4.9 2.3 3.8 0.4 4.9 2.6 342 10 355 165 11.1 0 11.4 10.9 06/04/2006 21:30:00 3.6 0.4 4.6 2.6 3.2 0.7 4.9 1.1 3.5 0.4 4.6 2.3 347 9 3 165 11.1 0 11.4 10.9 06/04/2006 21:40:00 3.7 0.7 5.3 2.6 3.6 0.9 5.7 1.5 3.7 0.7 5.3 2.6 345 7 343 165 10.8 0 11.1 10.6 06/04/2006 21:50:00 4.2 0.6 6.1 3 4.2 0.8 6.1 2.6 4.2 0.7 6.1 3 345 5 344 165 11.1 0.1 11.4 10.9 06/04/2006 22:00:00 4.4 0.7 5.7 3 4.2 0.7 6.1 2.6 4.2 0.6 5.7 2.6 333 9 331 165 10.9 0.2 11.4 10.3 06/04/2006 22:10:00 4.4 0.5 6.1 3 4.4 0.5 6.1 3.4 3.9 0.5 4.9 2.3 316 11 301 165 11.5 0.1 11.9 10.9 06/04/2006 22:20:00 4.3 0.6 6.1 2.6 4.3 0.6 6.1 2.6 4.2 0.6 5.7 2.6 331 8 324 165 11.2 0 11.4 11.1 06/04/2006 22:30:00 3.6 0.6 5.7 2.3 3.6 0.6 5.3 2.3 3.3 0.6 4.9 1.9 318 8 322 165 11 0.1 11.4 10.9 06/04/2006 22:40:00 3.4 0.5 4.9 2.6 3.4 0.5 4.6 2.6 3 0.4 4.2 2.3 314 8 307 165 11.1 0 11.4 10.9 06/04/2006 22:50:00 3.9 0.5 6.1 2.3 4 0.5 5.7 2.3 2.9 0.4 4.2 1.9 302 7 300 165 11 0.2 11.4 10.6 06/04/2006 23:00:00 4.2 0.5 5.3 3 4.2 0.5 5.3 3 3.2 0.6 4.9 1.9 301 8 321 165 11.2 0.2 11.7 10.6 06/04/2006 23:10:00 3.9 0.6 5.3 2.6 4 0.6 5.3 2.6 3.2 0.5 4.6 1.9 304 7 300 165 11.3 0.1 11.7 10.9 06/04/2006 23:20:00 4.5 0.5 5.7 3 4.5 0.5 5.7 3.4 3.7 0.7 5.3 1.5 301 10 315 165 11.4 0 11.7 11.1 06/04/2006 23:30:00 4.6 0.4 5.3 3.4 4.7 0.4 5.7 3.4 3.5 0.4 4.6 2.3 301 5 302 165 11.3 0 11.7 11.1 06/04/2006 23:40:00 4.8 0.4 6.1 3.4 4.8 0.4 5.7 3.8 3.9 0.5 5.3 2.3 307 6 306 165 11.1 0.2 11.7 10.9 06/04/2006 23:50:00 5.1 0.5 6.5 3.8 5.1 0.5 6.5 3.4 3.9 0.5 6.1 2.6 307 6 323 165 10.9 0 11.1 10.6 06/05/2006 00:00:00 4.6 0.5 5.7 3.4 4.6 0.4 5.7 3.4 3.4 0.6 5.3 1.9 300 10 291 165 10.8 0.2 11.1 10.3 06/05/2006 00:10:00 5.5 0.5 6.8 4.2 5.5 0.5 6.8 4.2 4.1 0.6 6.5 3 299 5 304 165 10.8 0.3 11.4 10.1 06/05/2006 00:20:00 5.8 0.8 7.2 3.4 5.7 0.8 7.2 3.4 4.4 0.7 6.5 2.6 304 7 302 165 10.9 0.1 11.1 10.6 06/05/2006 00:30:00 6.1 0.9 8 3.8 6.1 0.9 8 3.8 4.6 0.9 6.5 1.9 303 6 307 165 10.7 0.1 11.1 10.6 06/05/2006 00:40:00 6 0.8 8 4.2 6 0.9 8 3.8 4.9 0.7 7.2 3 306 6 307 165 11 0.1 11.4 10.6 06/05/2006 00:50:00 6.7 0.7 8.4 4.9 6.7 0.7 8.4 4.6 5.2 0.7 7.6 3.4 306 7 295 165 11.1 0.2 11.7 10.6 06/05/2006 01:00:00 6.9 0.9 8.8 4.9 6.9 0.8 8.8 4.9 5.5 0.9 7.6 3.4 306 6 307 165 11.3 0.2 11.7 10.9 06/05/2006 01:10:00 7 0.8 8.8 5.3 6.9 0.8 8.8 4.9 5.4 0.8 8 3.8 304 6 302 165 11.1 0.2 11.4 10.9 06/05/2006 01:20:00 7.6 0.8 9.1 5.7 7.6 0.8 9.1 5.3 6 0.8 8.4 3.8 305 5 305 165 11.1 0.2 11.4 10.9 06/05/2006 01:30:00 7.2 0.9 9.1 4.6 7.1 0.9 8.8 4.9 5.9 0.8 8 3.8 309 6 310 165 11 0.1 11.4 10.6 06/05/2006 01:40:00 6 0.6 7.6 4.2 5.9 0.6 8 4.2 5.4 0.8 7.6 3.4 314 6 321 165 10.7 0.3 11.4 9.8 06/05/2006 01:50:00 4.6 0.7 6.1 2.6 4.5 0.7 6.1 3 4.4 0.6 6.1 3 325 8 325 165 10.5 0.2 10.9 9.8 06/05/2006 02:00:00 4.3 0.6 5.7 2.6 4.2 0.6 5.7 2.6 4 0.5 5.7 2.6 329 10 328 165 10.4 0.2 10.9 9.6 06/05/2006 02:10:00 4.3 0.6 5.7 2.6 4.2 0.6 5.7 2.6 3.9 0.8 5.7 1.5 323 9 313 165 10.3 0 10.9 10.1 06/05/2006 02:20:00 4.8 0.6 6.8 3.4 4.8 0.6 6.8 3.4 4.6 0.6 6.5 3 322 10 319 165 10.6 0 10.9 10.3 06/05/2006 02:30:00 5.2 0.8 7.6 3.8 5.1 0.7 7.2 3.4 4.7 0.8 7.6 2.6 317 9 318 165 10.6 0.1 10.9 10.3 06/05/2006 02:40:00 5.3 0.7 6.8 3.4 5.3 0.7 6.8 3.4 4.7 0.7 6.5 2.6 319 10 337 165 10.4 0 10.9 10.1 06/05/2006 02:50:00 5 0.7 8 3.4 4.9 0.7 8.4 3.4 4.5 0.5 6.5 3 323 12 346 165 10.1 0 10.3 9.8 06/05/2006 03:00:00 5.1 0.6 6.8 3.4 5.1 0.6 6.8 3 4.6 0.7 6.1 2.6 315 9 303 165 10.5 0 10.9 10.3 06/05/2006 03:10:00 5.4 1 8.4 3.4 5.3 1 8 3 4.8 1 7.6 3 327 12 340 165 10.2 0.1 10.6 9.8 06/05/2006 03:20:00 5.5 0.6 7.2 4.2 5.4 0.6 6.8 3.8 5 0.6 6.8 3.4 314 9 315 165 10.1 0.1 10.6 9.6 06/05/2006 03:30:00 5.8 0.9 8.4 3 5.6 0.9 8 3 5.1 0.9 7.2 2.6 320 13 331 165 10 0 10.3 9.6 06/05/2006 03:40:00 5.8 0.8 8 3.8 5.7 0.7 7.6 4.2 5.3 0.7 7.6 3.8 325 9 320 165 9.9 0 10.3 9.6 06/05/2006 03:50:00 5.8 0.7 8 4.2 5.7 0.7 8 3.8 5.1 1 7.6 3 313 13 333 165 10.1 0.1 10.6 9.6 06/05/2006 04:00:00 5.7 0.6 7.2 4.2 5.6 0.6 6.8 4.2 4.8 0.7 6.5 3 309 9 340 165 10.3 0 10.6 10.1 06/05/2006 04:10:00 4.5 0.6 6.1 3.4 4.5 0.6 5.7 3.4 4 0.7 6.1 2.3 313 9 314 165 10.3 0 10.6 9.8 06/05/2006 04:20:00 5 0.7 6.8 3 5 0.7 6.8 3 4.3 0.7 6.1 2.3 309 8 307 165 10.1 0.1 10.3 9.8 06/05/2006 04:30:00 4.9 0.7 6.8 3.4 4.9 0.7 7.2 3.4 4 0.7 6.1 2.6 306 8 314 165 10.1 0.1 10.6 9.6 06/05/2006 04:40:00 4.4 0.7 6.5 2.3 4.4 0.7 6.1 2.3 3.7 0.7 5.7 1.9 305 11 298 165 10.5 0.2 10.9 10.1 06/05/2006 04:50:00 3.7 0.9 6.5 1.9 3.7 0.8 6.1 2.3 3.4 0.8 6.1 1.5 316 12 321 165 10.9 0.1 11.4 10.6 06/05/2006 05:00:00 3.5 0.6 5.3 1.9 3.6 0.6 4.9 2.3 3 0.6 4.6 1.1 297 10 301 165 10.9 0.1 11.4 10.6 06/05/2006 05:10:00 3.8 0.6 5.3 2.6 3.8 0.6 5.3 2.6 3.5 0.7 5.3 1.9 295 10 292 165 10.8 0 11.1 10.6 06/05/2006 05:20:00 4.9 0.7 6.8 3.4 5 0.7 6.8 3.4 4.4 0.6 6.1 3 298 8 288 165 10.9 0 11.1 10.6 06/05/2006 05:30:00 5.6 0.8 7.6 3.4 5.7 0.8 7.6 3.4 4.7 0.6 7.6 3 303 8 288 165 10.9 0.2 11.1 10.6 06/05/2006 05:40:00 6.7 0.6 8.4 4.9 6.7 0.6 8.4 4.9 5.4 0.8 7.6 3.4 294 7 294 165 11.1 0.2 11.4 10.9 06/05/2006 05:50:00 6.4 0.6 8 4.6 6.4 0.6 8.4 4.6 5.1 0.8 7.6 3 296 9 287 165 11.1 0.2 11.4 10.9 06/05/2006 06:00:00 4.6 1.2 7.2 1.1 4.6 1.2 6.8 1.1 4.2 1.1 7.2 1.1 290 12 301 165 11.3 0.1 11.7 10.9 06/05/2006 06:10:00 2.1 1 4.2 0.4 2.2 1 4.2 0.4 2.1 0.8 4.6 0.4 307 45 290 165 12 0.3 12.5 11.4 06/05/2006 06:20:00 1.1 0.6 2.6 0.4 1.1 0.6 2.6 0.4 1.1 0.6 2.3 0.4 297 28 288 165 12.8 0.3 13.3 12.2 06/05/2006 06:30:00 0.5 0.2 1.5 0.4 0.4 0.2 1.5 0.4 0.4 0.2 1.5 0.4 271 1 271 165 13.3 0.1 13.5 13 06/05/2006 06:40:00 0.9 0.3 1.5 0.4 0.7 0.3 1.5 0.4 0.9 0.3 1.5 0.4 206 18 198 165 13.2 0.1 13.5 12.5 06/05/2006 06:50:00 0.4 0.2 1.5 0.4 0.4 0.2 1.5 0.4 0.4 0 0.7 0.4 221 29 256 165 13.7 0.4 14.4 12.7 06/05/2006 07:00:00 0.8 0.4 1.9 0.4 0.6 0.4 1.9 0.4 0.5 0.2 1.5 0.4 307 49 15 165 14.2 0.2 14.9 13.5 06/05/2006 07:10:00 1.4 0.4 2.6 0.4 1.3 0.4 2.3 0.4 1.1 0.4 2.3 0.4 346 30 360 165 14.8 0.2 15.2 14.4 06/05/2006 07:20:00 1.8 0.5 3.4 0.4 1.8 0.6 3 0.4 1.7 0.6 3.4 0.4 28 18 24 165 14.6 0.2 15.2 14.4 06/05/2006 07:30:00 1.1 0.5 2.3 0.4 1 0.5 2.3 0.4 0.8 0.5 2.3 0.4 36 61 5 165 14.8 0.2 15.2 14.4 06/05/2006 07:40:00 2.3 1 4.6 0.4 2.2 0.9 4.2 0.4 2.1 0.8 3.8 0.4 35 33 2 165 14.9 0 15.2 14.6 06/05/2006 07:50:00 2 1 4.2 0.4 1.9 1 4.6 0.4 1.8 0.9 4.2 0.4 33 27 58 165 14.8 0 15.2 14.6 06/05/2006 08:00:00 2.4 0.8 4.6 0.7 2.2 0.8 4.2 0.7 2 0.9 4.9 0.4 32 30 360 165 14.9 0.3 15.7 14.4 06/05/2006 08:10:00 2.4 0.7 4.2 1.1 2 0.6 3.4 0.7 1.9 0.8 3.4 0.4 6 11 357 165 15.6 0.1 16 15.2 06/05/2006 08:20:00 1.9 0.5 3.4 0.4 1.8 0.6 3 0.4 1.8 0.5 3 0.7 32 23 14 165 15.5 0 15.7 15.2 06/05/2006 08:30:00 2.6 0.6 4.2 1.1 2.5 0.6 4.2 1.1 2.4 0.6 4.2 0.7 41 15 59 165 15.2 0.1 15.7 14.9 06/05/2006 08:40:00 3 0.5 4.2 1.5 3 0.5 4.2 1.5 3 0.5 4.2 1.1 46 27 17 165 14.8 0.1 15.5 14.6 06/05/2006 08:50:00 2.2 0.6 3.8 0.4 2.3 0.6 4.2 0.4 2.2 0.7 3.4 0.4 90 47 124 165 15.5 0.2 16 15.2 06/05/2006 09:00:00 2.7 1 4.9 0.4 2.8 0.9 5.3 0.7 2.7 1 5.3 0.4 113 45 175 165 16.2 0.2 16.8 15.7 06/05/2006 09:10:00 3.2 0.9 5.7 0.7 3.3 1 5.7 0.4 3.3 1 5.7 1.5 157 51 283 165 15.8 0 16.3 15.7 06/05/2006 09:20:00 2.8 1 5.3 0.7 2.8 1 5.3 0.7 2.7 1 5.7 0.4 152 45 147 165 16.1 0 16.3 16 06/05/2006 09:30:00 2.6 1.1 4.9 0.4 2.6 1.1 4.9 0.4 2.6 1.1 4.6 0.4 168 49 178 165 15.9 0.2 16.3 15.7 06/05/2006 09:40:00 2.9 0.6 4.6 1.5 2.9 0.6 4.6 1.1 3 0.6 4.6 1.1 145 17 164 165 16.1 0.4 16.8 15.2 06/05/2006 09:50:00 2.6 0.6 4.6 1.1 2.6 0.6 4.2 1.1 2.7 0.6 4.6 1.1 157 17 176 165 15.1 0.1 15.7 14.9 06/05/2006 10:00:00 2.5 0.6 4.6 0.7 2.5 0.6 4.9 0.7 2.5 0.6 3.8 1.1 135 13 141 165 15.2 0.1 15.7 14.9 06/05/2006 10:10:00 3.5 0.8 5.3 1.5 3.6 0.8 5.3 1.5 3.6 0.8 5.7 1.9 138 13 144 165 15.5 0 16.3 15.2 06/05/2006 10:20:00 3.8 0.6 5.3 2.3 3.8 0.7 5.7 2.3 3.8 0.5 5.3 2.3 144 12 139 165 15.8 0.2 16.3 15.5 06/05/2006 10:30:00 3.9 0.7 6.1 1.9 3.9 0.7 6.5 1.5 3.9 0.7 6.1 2.3 145 12 137 165 15.5 0.2 16.3 15.2 06/05/2006 10:40:00 3.9 0.6 5.7 2.6 3.9 0.6 6.1 2.3 4 0.6 6.1 3 152 10 149 165 15.1 0.2 15.7 14.6 06/05/2006 10:50:00 4.5 0.7 6.1 2.6 4.4 0.7 6.1 3 4.5 0.6 5.7 3 154 9 172 165 15.1 0.1 15.7 14.9 06/05/2006 11:00:00 4.9 0.7 7.2 3.8 4.9 0.7 7.2 3.4 5 0.8 7.2 3 133 11 136 165 15.5 0.1 16.3 15.2 06/05/2006 11:10:00 4.7 0.8 6.5 2.6 4.7 0.9 6.8 2.6 4.8 0.8 6.8 2.6 129 10 126 165 15.9 0.1 16.6 15.7 06/05/2006 11:20:00 4.4 0.8 6.5 3 4.5 0.8 6.5 2.6 4.5 0.7 6.8 2.6 135 14 129 165 15.9 0.2 16.6 15.7 06/05/2006 11:30:00 4.9 0.8 7.2 3 5 0.9 7.6 3 5.1 0.9 7.2 3 128 9 136 165 16.1 0.1 16.8 15.7 06/05/2006 11:40:00 4.6 0.9 6.5 1.5 4.6 0.9 6.8 1.5 4.7 0.8 6.5 1.9 123 11 118 165 15.9 0.2 16.8 15.7 06/05/2006 11:50:00 4.3 0.8 6.5 2.6 4.3 0.8 6.5 2.6 4.4 0.8 7.2 3 119 11 115 165 16.2 0.3 17.1 15.7 06/05/2006 12:00:00 4.9 0.7 7.2 3.4 4.9 0.7 7.2 3.4 4.9 0.7 7.2 3 126 11 110 165 16.6 0.1 17.1 16.3 06/05/2006 12:10:00 4.9 0.7 6.5 3.4 4.8 0.7 6.5 3 5 0.7 6.8 3 136 11 122 165 16.2 0.1 16.8 16 06/05/2006 12:20:00 4.1 0.6 5.7 2.3 4 0.6 5.7 2.6 4.2 0.7 6.1 1.9 163 13 156 165 14.8 0.6 16.3 14.1 06/05/2006 12:30:00 4.7 0.7 6.5 2.6 4.7 0.8 6.8 2.6 4.6 0.7 6.5 1.9 140 13 148 165 14.7 0.3 15.5 14.4 06/05/2006 12:40:00 4.3 0.6 6.8 2.3 4.3 0.6 6.8 1.9 4.3 0.7 6.1 2.6 132 13 128 165 15.2 0.1 15.7 14.9 06/05/2006 12:50:00 3.8 0.6 5.3 2.3 3.7 0.6 5.7 2.3 3.7 0.6 5.7 2.3 133 13 119 165 14.8 0.3 15.5 14.4 06/05/2006 13:00:00 3.6 0.7 5.3 1.1 3.6 0.7 4.9 1.5 3.7 0.7 5.3 1.9 133 11 126 165 14.6 0.2 15.5 14.4 06/05/2006 13:10:00 3.1 0.6 4.9 1.5 3.1 0.6 4.9 1.5 3.3 0.6 4.9 1.9 136 17 135 165 14.4 0.3 15.2 13.8 06/05/2006 13:20:00 3.6 0.7 6.1 2.3 3.7 0.7 5.7 2.3 3.6 0.6 5.3 2.3 136 13 134 165 14.6 0 15.2 14.4 06/05/2006 13:30:00 3.4 0.6 5.3 1.9 3.4 0.6 5.3 2.3 3.6 0.7 5.3 1.9 145 15 148 165 14.2 0.1 14.6 13.8 06/05/2006 13:40:00 4.1 0.6 5.7 2.6 4.1 0.6 5.7 2.6 4.1 0.6 6.1 1.9 146 11 142 165 14.2 0.1 14.9 13.8 06/05/2006 13:50:00 4.2 0.8 6.5 2.3 4.2 0.8 7.2 1.9 4.2 0.8 6.8 2.3 144 12 146 165 14.5 0.2 15.2 14.1 06/05/2006 14:00:00 4.5 0.6 6.8 2.6 4.5 0.6 6.8 2.6 4.5 0.7 7.6 2.6 142 11 128 165 15 0.1 15.7 14.6 06/05/2006 14:10:00 4.3 0.7 6.1 3 4.2 0.7 6.1 2.6 4.4 0.7 6.1 2.6 145 11 132 165 14.6 0.1 15.2 14.4 06/05/2006 14:20:00 4.6 0.6 6.1 3 4.5 0.5 6.1 3 4.7 0.6 6.5 3.4 145 10 148 165 14.5 0.2 15.2 14.1 06/05/2006 14:30:00 4.7 0.5 6.8 3.4 4.7 0.5 6.8 3.4 4.8 0.5 6.8 3.4 142 8 161 165 14.6 0 14.9 14.4 06/05/2006 14:40:00 4.8 0.6 6.5 3 4.8 0.6 6.5 3 4.9 0.5 6.5 3 139 12 137 165 14.7 0 15.2 14.4 06/05/2006 14:50:00 4.7 0.6 6.1 3 4.7 0.6 6.1 3 4.7 0.6 6.1 3.4 142 13 135 165 14.3 0.3 14.9 13.8 06/05/2006 15:00:00 4.8 0.7 6.5 3 4.8 0.7 6.5 3 4.8 0.7 6.5 2.6 140 9 162 165 14 0.1 14.6 13.8 06/05/2006 15:10:00 5.7 0.5 6.8 4.6 5.7 0.5 6.8 4.2 5.7 0.6 7.2 3.8 138 7 136 165 14.4 0.2 14.9 14.1 06/05/2006 15:20:00 6 0.5 7.2 4.6 6 0.5 7.2 4.2 5.9 0.5 7.2 4.6 138 6 137 165 14.5 0.2 15.2 14.1 06/05/2006 15:30:00 6.1 0.5 7.6 4.6 6.1 0.5 7.6 4.6 6 0.6 7.2 4.6 137 5 138 165 14.8 0.1 15.2 14.6 06/05/2006 15:40:00 6.1 0.5 7.2 4.6 6.1 0.5 7.2 4.2 6 0.5 7.2 4.9 133 7 127 165 14.9 0.2 15.2 14.6 06/05/2006 15:50:00 6.4 0.5 7.6 5.3 6.4 0.5 7.6 4.9 6.4 0.5 7.6 4.6 134 4 139 165 14.6 0 14.9 14.4 06/05/2006 16:00:00 6.9 0.6 8.4 5.3 6.9 0.6 8.4 5.7 6.8 0.6 8.4 4.9 136 6 131 165 14.4 0 14.6 14.1 06/05/2006 16:10:00 6.7 0.6 8.4 4.9 6.8 0.6 8.4 5.3 6.7 0.6 8.4 4.9 136 8 129 165 14.7 0.1 15.2 14.6 06/05/2006 16:20:00 6.7 0.6 8 4.9 6.7 0.7 8.4 4.9 6.6 0.6 8.4 4.9 132 7 131 165 14.6 0 15.2 14.6 06/05/2006 16:30:00 7.1 0.7 8.4 4.9 7.1 0.7 8.8 5.3 6.9 0.7 8.4 4.9 129 6 128 165 14.4 0.2 14.9 14.1 06/05/2006 16:40:00 7 0.7 8.8 4.2 7.1 0.7 8.8 4.6 6.9 0.7 8.4 4.9 129 7 129 165 14.2 0.1 14.6 13.8 06/05/2006 16:50:00 7 0.6 8.4 4.9 7 0.6 8.8 4.9 6.8 0.7 8.4 4.6 125 5 122 165 14.2 0.1 14.4 13.8 06/05/2006 17:00:00 5.8 0.8 7.6 4.2 5.9 0.7 7.6 4.2 5.7 0.7 7.2 3.8 120 6 121 165 14.2 0 14.6 13.8 06/05/2006 17:10:00 4.9 0.5 6.1 3.4 4.9 0.5 6.5 3 4.8 0.6 6.1 3.4 115 7 111 165 14.4 0 14.6 14.4 06/05/2006 17:20:00 4 0.6 5.3 2.3 4 0.6 5.3 2.3 3.9 0.7 5.7 2.3 117 11 108 165 14.3 0 14.6 14.1 06/05/2006 17:30:00 3.7 0.4 4.6 2.6 3.7 0.4 4.9 2.3 3.8 0.5 5.3 2.3 114 12 111 165 14.4 0 14.6 14.4 06/05/2006 17:40:00 1.8 1 4.2 0.4 1.8 1 4.2 0.4 1.8 1.2 3.8 0.4 172 72 127 165 14.8 0.3 15.7 14.6 06/05/2006 17:50:00 1.4 0.8 4.2 0.4 1.4 0.9 4.2 0.4 1.3 1 4.2 0.4 333 102 104 165 16.2 0.3 16.8 15.7 06/05/2006 18:00:00 2.5 0.7 4.6 0.7 2.5 0.7 5.3 0.7 2.6 0.7 4.2 1.1 131 20 121 165 15.7 0.3 16.6 15.2 06/05/2006 18:10:00 2.7 0.5 3.4 1.5 2.7 0.5 3.8 1.1 2.6 0.5 3.4 1.1 128 13 116 165 15.1 0 15.5 14.9 06/05/2006 18:20:00 3.2 0.5 4.2 1.9 3.2 0.5 4.2 1.9 3.2 0.5 4.6 1.9 133 7 126 165 15.2 0 15.5 14.9 06/05/2006 18:30:00 3.5 0.4 4.6 2.3 3.5 0.4 4.6 2.3 3.5 0.4 4.6 2.3 147 9 133 165 14.9 0 15.2 14.6 06/05/2006 18:40:00 3.1 0.4 4.2 2.3 3.1 0.4 4.2 2.3 3.2 0.5 4.2 1.9 144 11 144 165 14.8 0.1 15.2 14.6 06/05/2006 18:50:00 3.8 0.6 5.7 2.6 3.8 0.5 5.7 2.6 3.8 0.5 5.3 2.6 159 15 179 165 14.4 0 14.9 14.1 06/05/2006 19:00:00 3.7 0.6 5.7 2.3 3.6 0.6 5.3 2.3 3.5 0.6 5.3 1.5 170 15 171 165 14.3 0 14.6 13.8 06/05/2006 19:10:00 4.1 0.6 5.3 2.6 4 0.6 5.3 2.6 4 0.6 5.7 2.3 178 9 186 165 14.1 0.1 14.4 13.5 06/05/2006 19:20:00 3.3 0.5 4.9 2.3 3.2 0.5 4.6 1.9 3.2 0.4 4.2 2.3 163 12 176 165 14 0 14.1 13.8 06/05/2006 19:30:00 3.8 0.4 4.9 2.6 3.8 0.4 4.9 2.6 3.9 0.4 4.9 2.6 152 9 150 165 13.5 0.1 13.8 13 06/05/2006 19:40:00 3.4 0.4 4.6 2.3 3.3 0.4 4.6 2.3 3.2 0.5 4.6 2.3 160 8 176 165 13.4 0 13.5 13.3 06/05/2006 19:50:00 4.3 0.5 5.3 3 4.2 0.5 5.7 3 4.1 0.5 5.7 2.6 164 7 165 165 13.3 0 13.5 13 06/05/2006 20:00:00 3.7 0.6 4.9 2.3 3.6 0.6 4.6 1.9 3.5 0.6 4.9 1.9 160 13 163 165 13 0 13.3 13 06/05/2006 20:10:00 3.7 0.6 4.9 1.1 3.6 0.6 4.9 1.5 3.6 0.7 4.9 1.5 166 10 165 165 13 0 13.3 12.7 06/05/2006 20:20:00 3.7 0.5 4.6 2.3 3.5 0.5 4.6 2.3 3.5 0.5 4.6 1.9 168 10 176 165 12.8 0.1 13.3 12.2 06/05/2006 20:30:00 2.9 0.4 3.8 2.3 2.8 0.4 3.8 1.9 2.9 0.3 3.8 1.9 158 9 162 165 12.6 0.1 13 12.2 06/05/2006 20:40:00 3.7 0.4 4.6 2.6 3.6 0.4 4.6 2.6 3.6 0.4 4.6 2.6 155 6 158 165 12.3 0.2 12.7 11.7 06/05/2006 20:50:00 3.4 0.4 4.6 2.3 3.3 0.4 4.2 2.3 3.4 0.4 4.6 2.3 160 7 155 165 12.3 0.1 12.5 11.7 06/05/2006 21:00:00 3 0.5 4.6 1.9 2.9 0.5 4.6 1.5 2.8 0.4 3.8 1.9 179 14 185 165 12.2 0 12.5 11.7 06/05/2006 21:10:00 2.3 0.4 3.4 1.5 2.3 0.4 3 1.5 2.1 0.4 3.4 1.5 203 14 200 165 12.4 0 12.5 11.9 06/05/2006 21:20:00 2.2 0.2 3 1.5 2.2 0.2 3 1.9 1.9 0.3 2.6 1.1 219 5 210 165 12.2 0 12.5 11.9 06/05/2006 21:30:00 2 0.4 2.6 0.7 2 0.5 2.6 0.4 2 0.5 3 0.7 172 39 214 165 11.9 0.2 12.2 11.4 06/05/2006 21:40:00 1.1 0.5 2.6 0.4 1.1 0.5 2.6 0.4 0.8 0.4 1.9 0.4 200 23 234 165 11.6 0.1 11.9 11.1 06/05/2006 21:50:00 1.2 0.5 3 0.4 1.2 0.5 3 0.4 1.2 0.4 2.3 0.4 182 22 205 165 11.3 0.1 11.9 10.9 06/05/2006 22:00:00 2.3 0.5 3.4 1.5 2.4 0.5 3.4 1.1 2.3 0.6 3.4 0.7 213 9 204 165 11.7 0.2 11.9 11.1 06/05/2006 22:10:00 3.1 0.2 3.8 2.6 3.2 0.2 3.8 2.6 3.3 0.3 4.2 2.6 202 4 208 165 11.7 0 11.9 11.1 06/05/2006 22:20:00 2.8 0.3 3.8 2.3 2.8 0.3 3.8 2.3 3 0.2 3.8 2.6 200 3 202 165 11.6 0 11.9 11.4 06/05/2006 22:30:00 2.2 0.3 2.6 1.9 2.2 0.3 3 1.9 2.3 0.3 3 1.9 192 3 194 165 11.4 0 11.7 11.1 06/05/2006 22:40:00 2.1 0.3 2.6 1.1 2 0.3 2.6 1.1 1.9 0.4 2.6 1.1 189 6 187 165 11.2 0 11.7 10.9 06/05/2006 22:50:00 2 0.2 2.3 1.5 1.9 0.2 2.3 1.5 1.9 0.2 2.3 1.5 187 3 183 165 11.2 0.1 11.7 10.9 06/05/2006 23:00:00 1.6 0.3 2.3 1.1 1.6 0.3 2.3 0.7 1.4 0.3 1.9 0.4 181 3 181 165 10.9 0 11.4 10.6 06/05/2006 23:10:00 1.1 0.2 1.5 0.7 1 0.2 1.5 0.4 0.9 0.2 1.5 0.7 180 3 184 165 10.9 0 11.1 10.6 06/05/2006 23:20:00 0.6 0.3 1.5 0.4 0.6 0.3 1.1 0.4 0.6 0.3 1.1 0.4 154 11 164 165 10.8 0.1 11.1 10.6 06/05/2006 23:30:00 0.4 0 0.7 0.4 0.4 0.1 0.7 0.4 0.4 0 0.4 0.4 148 0 148 165 11.1 0 11.4 10.9 06/05/2006 23:40:00 0.7 0.4 1.5 0.4 0.7 0.4 1.5 0.4 0.7 0.4 1.5 0.4 163 15 181 165 11.1 0.1 11.4 10.6 06/05/2006 23:50:00 0.8 0.3 1.5 0.4 0.8 0.3 1.5 0.4 1 0.2 1.5 0.4 185 10 169 165 11.3 0 11.7 10.9 06/06/2006 00:00:00 1.3 0.3 1.9 0.4 1.4 0.4 2.3 0.7 1.3 0.4 1.9 0.4 215 11 228 165 11.5 0 11.9 11.1 06/06/2006 00:10:00 1.7 0.6 3 0.4 1.9 0.5 3 0.7 1.6 0.3 2.6 0.7 279 22 297 165 11.5 0.1 11.9 11.1 06/06/2006 00:20:00 3.1 0.3 3.8 1.9 3.1 0.3 3.8 2.3 2.4 0.3 3 1.5 303 5 307 165 11.2 0 11.7 10.9 06/06/2006 00:30:00 3 0.3 3.8 2.3 3.1 0.3 3.8 2.6 2.1 0.3 3 1.1 298 3 305 165 11 0 11.1 10.9 06/06/2006 00:40:00 2.5 0.3 3 1.9 2.6 0.3 3.4 1.9 1.7 0.2 2.3 1.1 297 2 296 165 10.9 0 11.4 10.9 06/06/2006 00:50:00 1.8 0.5 2.6 0.4 2 0.4 3 0.7 2 0.4 3 0.7 294 3 295 165 11.1 0 11.4 10.9 06/06/2006 01:00:00 0.4 0.1 0.7 0.4 0.4 0.1 1.1 0.4 0.5 0.3 1.5 0.4 295 0 296 165 11.3 0 11.4 11.1 06/06/2006 01:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.7 0.4 295 0 165 165 11.1 0 11.4 10.9 06/06/2006 01:20:00 0.4 0 0.4 0.4 0.4 0.1 0.7 0.4 0.4 0 0.7 0.4 263 17 165 165 11.3 0 11.7 10.9 06/06/2006 01:30:00 0.7 0.4 1.5 0.4 0.8 0.4 1.5 0.4 0.8 0.4 1.5 0.4 289 32 316 165 11 0.2 11.4 10.3 06/06/2006 01:40:00 0.8 0.4 1.5 0.4 0.7 0.3 1.5 0.4 0.7 0.4 1.5 0.4 343 8 325 165 10.5 0 10.9 10.3 06/06/2006 01:50:00 0.4 0.1 1.1 0.4 0.4 0.1 1.1 0.4 0.4 0.1 0.7 0.4 298 102 150 165 10.3 0.2 10.9 9.8 06/06/2006 02:00:00 0.6 0.4 1.9 0.4 0.7 0.4 1.9 0.4 0.5 0.3 1.5 0.4 244 45 287 165 11 0.3 11.7 10.3 06/06/2006 02:10:00 1.9 0.3 2.6 1.1 2.1 0.3 2.6 1.5 1.7 0.5 2.3 0.7 287 3 286 165 11.5 0 11.7 11.1 06/06/2006 02:20:00 1 0.3 1.9 0.4 1.3 0.3 1.9 0.7 0.7 0.3 1.5 0.4 294 0 294 165 11.4 0 11.7 11.1 06/06/2006 02:30:00 0.8 0.3 1.9 0.4 1.2 0.3 1.9 0.7 0.8 0.2 1.5 0.4 272 21 245 165 11.3 0.1 11.7 10.9 06/06/2006 02:40:00 0.7 0.3 1.5 0.4 1.4 0.3 1.9 0.4 0.6 0.3 1.5 0.4 264 3 268 165 10.7 0.3 11.7 9.8 06/06/2006 02:50:00 0.6 0.3 1.5 0.4 0.9 0.4 1.5 0.4 0.6 0.3 1.9 0.4 273 10 268 165 9.8 0.3 10.3 9 06/06/2006 03:00:00 0.5 0.2 1.1 0.4 0.8 0.4 1.9 0.4 0.4 0.1 1.1 0.4 279 9 290 165 10 0.3 10.6 9 06/06/2006 03:10:00 0.4 0.1 1.1 0.4 0.5 0.2 1.9 0.4 0.4 0 0.4 0.4 255 12 243 165 10.1 0.1 10.6 9.8 06/06/2006 03:20:00 1.5 0.5 2.3 0.4 1.7 0.4 2.6 0.4 1.2 0.5 2.3 0.4 282 15 284 165 10.1 0.1 10.6 9.6 06/06/2006 03:30:00 0.8 0.4 1.9 0.4 1.1 0.4 1.9 0.4 1.1 0.4 2.3 0.4 306 8 298 165 10.1 0.2 10.6 9.6 06/06/2006 03:40:00 0.4 0 0.4 0.4 0.4 0 0.7 0.4 0.4 0 0.4 0.4 313 0 165 165 9.6 0.1 10.3 9 06/06/2006 03:50:00 0.6 0.3 1.1 0.4 0.8 0.3 1.5 0.4 0.7 0.3 1.5 0.4 186 79 133 165 9.7 0.2 10.1 9 06/06/2006 04:00:00 0.5 0.2 1.1 0.4 0.9 0.2 1.1 0.7 0.4 0.1 1.1 0.4 137 0 137 165 9.4 0 9.6 9 06/06/2006 04:10:00 0.9 0.2 1.5 0.4 1.1 0.2 1.5 0.7 1 0.2 1.5 0.7 134 3 136 165 9.6 0.1 9.8 9.3 06/06/2006 04:20:00 0.4 0.1 0.7 0.4 0.5 0.2 1.1 0.4 0.5 0.2 1.1 0.4 130 0 129 165 10.1 0.1 10.3 9.8 06/06/2006 04:30:00 0.4 0 0.4 0.4 0.4 0.2 1.1 0.4 0.4 0.1 0.7 0.4 130 0 165 165 10.1 0 10.3 9.8 06/06/2006 04:40:00 0.5 0.2 1.1 0.4 0.7 0.3 1.5 0.4 0.7 0.3 1.1 0.4 131 2 130 165 10.3 0 10.6 10.1 06/06/2006 04:50:00 0.5 0.2 1.1 0.4 0.6 0.4 1.5 0.4 0.5 0.3 1.5 0.4 194 38 252 165 10.7 0.1 11.1 10.3 06/06/2006 05:00:00 0.6 0.3 1.5 0.4 1.2 0.4 1.9 0.4 1.3 0.2 1.9 0.7 251 2 252 165 11.2 0.2 11.7 10.6 06/06/2006 05:10:00 0.6 0.3 1.5 0.4 1 0.3 1.5 0.4 0.8 0.4 1.5 0.4 241 5 233 165 11.7 0.2 11.9 11.1 06/06/2006 05:20:00 0.8 0.2 1.1 0.4 1.2 0.2 1.5 0.7 1.1 0.2 1.5 0.7 222 7 233 165 11.8 0.1 12.2 11.7 06/06/2006 05:30:00 0.4 0.2 1.1 0.4 0.9 0.2 1.5 0.4 0.8 0.2 1.5 0.4 216 0 217 165 12.2 0 12.5 11.7 06/06/2006 05:40:00 0.4 0 0.4 0.4 0.9 0.3 1.5 0.4 0.6 0.3 1.1 0.4 206 5 165 165 12.4 0.2 12.7 11.9 06/06/2006 05:50:00 1 0.6 1.9 0.4 1.4 0.2 1.9 1.1 1.3 0.2 1.5 0.7 195 4 193 165 12.6 0 12.7 12.2 06/06/2006 06:00:00 1.3 0.2 1.5 1.1 1.2 0.2 1.5 0.7 0.9 0.2 1.5 0.4 191 1 191 165 12.8 0.1 13 12.2 06/06/2006 06:10:00 1.3 0.2 1.5 1.1 1.3 0.2 1.5 0.7 0.7 0.2 1.1 0.4 180 1 185 165 12.9 0.1 13.3 12.7 06/06/2006 06:20:00 0.8 0.3 1.5 0.4 0.7 0.4 1.5 0.4 0.6 0.4 1.9 0.4 170 18 143 165 13.1 0 13.3 12.5 06/06/2006 06:30:00 1.4 0.2 1.9 1.1 1.4 0.2 1.9 1.1 1.4 0.2 1.9 0.7 119 2 124 165 12.6 0.1 13 11.9 06/06/2006 06:40:00 1.7 0.2 1.9 1.1 1.7 0.2 2.3 1.1 1.5 0.2 2.3 0.7 128 2 125 165 12.6 0 12.7 12.2 06/06/2006 06:50:00 1.3 0.3 2.3 0.7 1.3 0.3 2.3 0.4 1.1 0.4 1.9 0.4 125 13 128 165 12.9 0.1 13.3 12.5 06/06/2006 07:00:00 1.2 0.4 2.6 0.4 1.1 0.4 2.6 0.4 1.1 0.4 2.3 0.4 151 7 143 165 13.3 0 13.5 12.7 06/06/2006 07:10:00 1.6 0.3 2.6 1.1 1.6 0.3 2.6 1.1 1.6 0.3 2.3 0.7 142 10 147 165 13.3 0 13.5 12.7 06/06/2006 07:20:00 1.7 0.4 2.6 0.7 1.8 0.4 2.6 0.4 1.7 0.3 2.6 0.7 123 9 122 165 13.5 0.1 14.1 13 06/06/2006 07:30:00 1.8 0.3 2.6 1.1 1.8 0.3 2.6 0.7 1.7 0.4 2.6 0.4 112 11 108 165 13.5 0.2 13.8 12.7 06/06/2006 07:40:00 2.1 0.4 3 0.4 2.1 0.4 3 0.7 2.1 0.4 3 0.7 121 10 136 165 13.9 0.2 14.4 13.3 06/06/2006 07:50:00 1.9 0.4 3 0.7 2 0.4 3 0.7 1.9 0.4 3 0.4 109 13 102 165 14 0 14.6 13.8 06/06/2006 08:00:00 1.7 0.6 3 0.4 1.8 0.6 3.4 0.4 1.6 0.6 3 0.4 118 11 122 165 14.2 0 14.6 13.5 06/06/2006 08:10:00 2.3 0.4 3.4 1.1 2.3 0.4 3.4 1.1 2.4 0.5 3.8 1.1 124 12 128 165 13.9 0 14.1 13.3 06/06/2006 08:20:00 2.1 0.4 3 1.1 2.1 0.5 3.4 0.7 2.1 0.4 3.4 1.1 117 15 145 165 14.1 0 14.4 13.5 06/06/2006 08:30:00 2.1 0.4 3.4 0.7 2.2 0.4 3.4 0.4 2.1 0.5 3.4 0.7 117 12 116 165 14 0.2 14.6 13.5 06/06/2006 08:40:00 2.3 0.5 3.4 0.7 2.4 0.5 3.4 1.1 2.3 0.6 3.8 0.7 117 17 115 165 14.6 0 14.9 14.4 06/06/2006 08:50:00 2.2 0.5 3.4 1.1 2.3 0.5 3.8 1.1 2.2 0.4 3.8 1.5 125 14 128 165 14.5 0 14.9 14.4 06/06/2006 09:00:00 2.3 0.5 3.8 1.1 2.4 0.5 3.8 1.1 2.2 0.6 3.8 0.4 120 14 144 165 14.6 0.1 14.9 14.4 06/06/2006 09:10:00 2.5 0.4 3.4 1.5 2.5 0.4 3.8 1.5 2.5 0.5 4.2 0.7 120 14 157 165 14.7 0.1 15.2 14.4 06/06/2006 09:20:00 2.3 0.5 3.4 0.7 2.3 0.5 3.8 0.7 2.4 0.6 4.2 0.7 123 14 121 165 14.8 0.1 15.2 14.6 06/06/2006 09:30:00 2.7 0.6 4.6 1.1 2.7 0.6 4.6 1.1 2.6 0.6 4.2 1.1 131 12 143 165 15.1 0 15.5 14.9 06/06/2006 09:40:00 3 0.4 4.2 1.9 3 0.4 4.6 2.3 3.1 0.4 4.2 1.9 138 8 142 165 14.6 0.1 15.2 14.4 06/06/2006 09:50:00 3.1 0.3 4.2 2.3 3.1 0.4 4.6 2.3 3.1 0.3 4.2 2.3 135 6 136 165 14.5 0 14.9 14.4 06/06/2006 10:00:00 3.4 0.5 4.6 1.9 3.4 0.5 4.9 1.9 3.3 0.4 4.6 2.3 134 8 136 165 14.6 0 14.9 14.4 06/06/2006 10:10:00 3.3 0.5 4.9 1.9 3.3 0.5 5.3 1.9 3.3 0.5 4.9 2.3 133 8 138 165 14.9 0.1 15.5 14.6 06/06/2006 10:20:00 3.2 0.5 5.3 1.9 3.2 0.5 4.9 2.3 3.2 0.6 4.9 2.3 133 10 121 165 14.6 0.1 15.2 14.4 06/06/2006 10:30:00 3.2 0.4 4.6 2.3 3.2 0.5 4.6 2.3 3.3 0.5 4.6 2.3 133 10 137 165 14.6 0 14.9 14.4 06/06/2006 10:40:00 3 0.4 4.6 1.9 3 0.5 4.6 1.9 3 0.5 5.3 2.3 133 10 108 165 14.4 0.1 14.9 14.1 06/06/2006 10:50:00 3.3 0.6 5.7 1.9 3.3 0.6 5.7 1.9 3.3 0.7 5.3 1.9 135 14 141 165 14.1 0.1 14.4 13.8 06/06/2006 11:00:00 3.8 0.5 5.3 2.6 3.8 0.5 5.3 2.6 3.9 0.6 5.3 2.3 130 9 111 165 13.7 0 14.4 13.3 06/06/2006 11:10:00 4.3 0.5 6.1 2.6 4.4 0.5 6.1 2.6 4.5 0.5 6.1 3.4 134 9 145 165 13.4 0 13.8 13 06/06/2006 11:20:00 4.2 0.5 5.7 3 4.2 0.5 6.1 3 4.3 0.6 6.1 3 133 9 137 165 13.3 0 13.8 13 06/06/2006 11:30:00 4.6 0.6 6.5 3 4.6 0.6 6.5 3 4.7 0.7 6.8 2.3 129 10 118 165 13.2 0.1 13.5 13 06/06/2006 11:40:00 4.8 0.6 6.8 3.4 4.9 0.7 6.8 3.4 4.9 0.7 6.5 3 131 10 128 165 13.3 0 13.5 13 06/06/2006 11:50:00 5.3 0.7 7.2 3.8 5.4 0.8 7.6 3.8 5.5 0.6 7.6 3.8 133 10 134 165 13.3 0.1 13.5 13 06/06/2006 12:00:00 5.3 0.5 7.6 3.8 5.3 0.5 7.6 3.8 5.4 0.6 6.8 3.4 128 7 123 165 13 0.1 13.3 12.7 06/06/2006 12:10:00 5.3 0.7 7.2 3.8 5.4 0.7 7.2 3.4 5.5 0.6 7.2 3.4 133 10 148 165 13.1 0.3 13.5 12.7 06/06/2006 12:20:00 5.3 0.7 8 3.4 5.3 0.8 8 3 5.4 0.7 7.2 3 136 11 121 165 12.9 0.2 13.5 12.5 06/06/2006 12:30:00 5.4 0.6 7.2 4.2 5.5 0.6 7.2 3.8 5.6 0.6 7.2 4.2 135 9 134 165 13.2 0 13.5 12.7 06/06/2006 12:40:00 5.1 0.7 7.2 3.4 5.1 0.6 7.2 3.4 5.3 0.7 8 3.8 137 9 130 165 13.1 0.1 13.5 12.7 06/06/2006 12:50:00 5.1 0.6 6.5 3.8 5.1 0.6 7.2 3.8 5.2 0.6 6.8 3 136 10 128 165 13.1 0.3 13.8 12.5 06/06/2006 13:00:00 5.5 0.8 7.2 3.8 5.5 0.8 7.6 3.8 5.7 0.8 7.6 3.4 138 9 132 165 13.3 0.1 13.8 13 06/06/2006 13:10:00 5.9 0.6 7.2 4.2 6 0.6 8 4.2 6 0.7 8 4.2 133 8 129 165 13.6 0.1 13.8 13 06/06/2006 13:20:00 6.2 0.7 8.4 4.2 6.2 0.7 8 4.6 6.4 0.7 8.8 4.9 131 8 119 165 13.5 0 13.8 13 06/06/2006 13:30:00 6.2 0.6 8 4.2 6.3 0.6 7.6 4.2 6.3 0.5 7.6 4.9 126 7 127 165 13.7 0 14.1 13.3 06/06/2006 13:40:00 6.2 0.5 8 4.9 6.3 0.6 8 4.9 6.3 0.6 8 4.6 128 6 126 165 13.3 0.1 13.8 13 06/06/2006 13:50:00 6.2 0.6 8 4.6 6.2 0.6 8 4.6 6.3 0.6 7.6 4.6 131 7 128 165 13.3 0.2 14.1 13 06/06/2006 14:00:00 6 0.5 7.6 4.6 6 0.6 7.6 4.9 6.2 0.6 8 4.6 129 6 142 165 12.8 0.1 13.5 12.5 06/06/2006 14:10:00 6.4 0.6 8 4.9 6.4 0.6 8.4 4.9 6.5 0.6 8.4 4.9 134 7 126 165 13.1 0.2 13.8 12.7 06/06/2006 14:20:00 6.2 0.6 8.4 4.9 6.2 0.7 8 4.9 6.3 0.7 8.4 4.6 131 7 114 165 13.1 0.1 13.5 12.7 06/06/2006 14:30:00 5.8 0.5 8.4 4.6 5.8 0.6 8.8 4.6 5.9 0.6 8.4 4.6 134 8 106 165 13.3 0.1 13.8 13 06/06/2006 14:40:00 5.8 0.6 7.6 4.6 5.8 0.7 7.6 4.6 6 0.6 8.4 4.9 134 10 116 165 13.4 0 13.8 13.3 06/06/2006 14:50:00 5.7 0.7 8 4.2 5.8 0.7 8.4 4.2 5.8 0.7 8 3.8 130 8 121 165 13.1 0.2 13.5 12.7 06/06/2006 15:00:00 6.1 0.6 8 4.2 6.2 0.7 8 4.6 5.9 0.8 8 4.2 124 8 130 165 13 0.1 13.3 12.7 06/06/2006 15:10:00 6 0.6 7.2 4.2 6 0.6 7.6 4.2 5.9 0.7 7.6 3.8 125 8 133 165 12.9 0 13.3 12.5 06/06/2006 15:20:00 5.5 0.8 7.6 3.4 5.5 0.8 7.6 3.4 5.3 0.8 8 3.4 124 9 125 165 13 0.2 13.3 12.7 06/06/2006 15:30:00 5.7 0.6 7.2 4.2 5.8 0.6 7.2 4.2 5.6 0.7 7.2 3.8 122 6 121 165 12.8 0.1 13.3 12.5 06/06/2006 15:40:00 5.2 0.6 7.2 3.4 5.2 0.6 7.6 3.8 5.1 0.6 7.2 3.4 128 9 109 165 12.8 0 13 12.5 06/06/2006 15:50:00 5.2 0.6 6.8 3.8 5.3 0.6 6.8 3.8 5.2 0.7 7.2 3.4 126 8 135 165 13 0 13.3 12.7 06/06/2006 16:00:00 5.6 0.8 7.6 3.4 5.7 0.8 7.6 3.4 5.6 0.8 7.6 3.8 123 7 119 165 12.9 0.1 13.3 12.7 06/06/2006 16:10:00 5.2 0.6 7.2 3.8 5.3 0.7 8 3.4 5.3 0.7 7.6 3 120 7 113 165 12.7 0 13 12.5 06/06/2006 16:20:00 5.2 0.6 6.8 3.8 5.3 0.6 6.8 3.8 5.3 0.6 7.2 3.4 123 9 116 165 12.9 0 13 12.5 06/06/2006 16:30:00 5.1 0.6 7.2 3.8 5.2 0.6 7.2 3.4 5.1 0.7 6.8 3 119 8 115 165 12.7 0 13 12.5 06/06/2006 16:40:00 4.8 0.6 6.1 3 4.8 0.6 6.5 3 4.7 0.7 7.2 3.4 116 8 103 165 12.7 0 13 12.5 06/06/2006 16:50:00 4.8 0.7 6.5 3 4.9 0.7 6.5 3 4.8 0.7 6.8 3 117 9 117 165 12.8 0.1 13 12.5 06/06/2006 17:00:00 4.8 0.8 6.5 3 4.9 0.8 6.8 3 4.7 0.8 7.2 3 117 9 112 165 12.9 0 13.3 12.5 06/06/2006 17:10:00 4.8 0.7 6.8 2.3 4.9 0.7 7.2 2.6 4.7 0.6 6.5 3.4 113 7 109 165 12.9 0 13 12.5 06/06/2006 17:20:00 5 0.8 7.2 3 5.1 0.8 7.6 3 4.9 0.7 6.8 3.4 108 9 109 165 13 0 13.3 12.7 06/06/2006 17:30:00 4.5 0.7 6.5 2.6 4.6 0.7 6.5 2.6 4.4 0.7 6.5 3 99 8 102 165 13.2 0 13.3 12.7 06/06/2006 17:40:00 3.8 0.6 5.3 2.3 3.9 0.6 5.3 2.6 3.7 0.6 5.3 2.3 95 9 87 165 13.5 0.1 13.8 13 06/06/2006 17:50:00 3.3 0.4 4.6 1.9 3.3 0.4 4.6 2.3 3.3 0.5 4.9 2.3 105 11 112 165 13.9 0 14.1 13.5 06/06/2006 18:00:00 4 0.4 5.7 2.6 4.1 0.5 6.1 2.6 4 0.5 5.7 3 113 6 106 165 13.7 0.1 13.8 13.3 06/06/2006 18:10:00 3.9 0.3 4.9 3 4 0.4 4.9 3 3.9 0.4 5.3 2.6 112 5 106 165 13.5 0 13.5 12.7 06/06/2006 18:20:00 3.3 0.4 4.2 1.9 3.4 0.4 4.2 2.3 3.2 0.4 4.2 1.5 116 7 111 165 13.5 0 13.8 13 06/06/2006 18:30:00 2.8 0.3 3.4 1.9 2.9 0.4 3.8 1.5 2.8 0.4 3.8 1.5 115 9 116 165 13.8 0.1 14.1 13.3 06/06/2006 18:40:00 2.6 0.3 3.4 1.9 2.6 0.3 3.4 1.9 2.6 0.3 3.4 1.9 109 8 102 165 13.5 0.1 13.5 13 06/06/2006 18:50:00 3.4 0.3 3.8 2.3 3.4 0.3 3.8 2.6 3.3 0.3 3.8 2.3 128 5 127 165 13.4 0 13.5 13.3 06/06/2006 19:00:00 3.6 0.4 4.6 2.3 3.6 0.4 4.6 2.3 3.5 0.4 4.2 2.3 123 9 133 165 13.1 0.1 13.3 12.7 06/06/2006 19:10:00 3.6 0.5 4.6 2.6 3.6 0.4 4.6 2.3 3.5 0.4 4.9 2.3 122 12 139 165 12.8 0 13 12.7 06/06/2006 19:20:00 3.8 0.3 4.6 3 3.8 0.3 4.6 3 3.7 0.3 4.6 2.6 128 9 135 165 12.5 0.1 12.7 12.5 06/06/2006 19:30:00 3.8 0.3 4.9 3 3.8 0.3 4.6 3 3.7 0.4 4.6 2.6 128 9 115 165 12.3 0 12.5 12.2 06/06/2006 19:40:00 3.5 0.5 4.6 2.6 3.5 0.5 4.6 2.3 3.5 0.4 4.6 2.6 136 8 143 165 11.8 0.2 12.2 11.4 06/06/2006 19:50:00 4.2 0.4 5.3 3 4.2 0.4 5.3 3 4.2 0.4 5.3 3 139 11 137 165 11.4 0.1 11.9 10.9 06/06/2006 20:00:00 3.5 0.5 4.9 2.3 3.6 0.5 4.9 2.3 3.6 0.5 4.9 2.3 128 9 126 165 11.2 0.1 11.7 10.9 06/06/2006 20:10:00 2.9 0.4 4.2 1.9 2.9 0.4 4.2 1.9 3 0.4 3.8 2.3 124 8 108 165 11 0 11.4 10.6 06/06/2006 20:20:00 2.6 0.4 3.8 1.5 2.6 0.4 3.4 1.5 2.7 0.3 3.4 1.9 129 8 129 165 11.1 0 11.4 10.9 06/06/2006 20:30:00 3.5 0.4 4.6 2.6 3.5 0.4 4.6 2.6 3.4 0.4 4.6 2.3 138 9 147 165 10.6 0 11.1 10.6 06/06/2006 20:40:00 3.7 0.7 5.7 1.5 3.6 0.8 6.1 1.9 3.6 0.8 6.1 1.9 148 11 151 165 10.4 0.1 10.9 10.1 06/06/2006 20:50:00 4.8 0.8 6.5 2.3 4.7 0.8 6.5 2.6 4.8 0.7 6.5 2.6 156 16 165 165 10.3 0 10.6 10.1 06/06/2006 21:00:00 4.2 0.7 6.1 1.9 4.1 0.6 6.1 1.9 4.1 0.6 5.7 2.3 161 13 144 165 10.4 0 10.9 10.3 06/06/2006 21:10:00 4.5 0.6 6.1 3 4.4 0.6 6.1 2.6 4.4 0.6 7.6 3 162 13 162 165 10.1 0.1 10.6 9.8 06/06/2006 21:20:00 4.7 0.6 6.5 3 4.5 0.6 6.1 2.6 4.6 0.7 6.5 2.6 156 13 158 165 10 0 10.3 9.6 06/06/2006 21:30:00 5.7 0.6 6.8 3.4 5.5 0.5 6.8 3.8 5.7 0.7 7.2 3.8 161 8 179 165 9.4 0.1 9.8 9 06/06/2006 21:40:00 5.2 0.7 6.8 3.8 5 0.6 6.5 3.8 5 0.7 6.8 3.8 162 7 169 165 8.9 0.2 9.3 8.5 06/06/2006 21:50:00 6 0.8 7.2 3 5.8 0.8 7.2 3 6 0.8 7.2 3.8 162 8 174 165 8.7 0.2 9.3 8.3 06/06/2006 22:00:00 6.1 0.5 7.2 4.6 5.9 0.5 6.8 4.2 6.1 0.6 7.6 4.2 164 5 162 165 8.4 0.2 8.8 8 06/06/2006 22:10:00 5.4 0.4 6.8 4.2 5.2 0.4 6.5 4.2 5.3 0.5 6.8 4.2 163 4 164 165 8.3 0.1 8.5 7.8 06/06/2006 22:20:00 5.7 0.6 7.2 4.6 5.5 0.6 6.8 4.2 5.7 0.6 7.2 4.6 161 9 165 165 8.3 0.1 8.5 8 06/06/2006 22:30:00 7 0.8 8.4 4.9 6.7 0.8 8 4.9 7 0.9 8.4 4.9 162 11 165 165 8.2 0 8.5 8 06/06/2006 22:40:00 7.5 0.5 8.4 6.1 7.2 0.4 8 5.7 7.5 0.5 8.8 5.7 164 17 165 165 8.1 0 8.3 7.8 06/06/2006 22:50:00 7 0.5 8.4 5.7 6.8 0.5 8 5.7 7 0.6 8.4 5.3 163 5 164 165 8 0 8.3 7.8 06/06/2006 23:00:00 6.7 0.6 8.4 5.3 6.5 0.6 8.4 4.9 7 0.7 8.4 5.3 168 7 158 165 8 0 8.3 7.8 06/06/2006 23:10:00 7.9 0.7 9.5 6.1 7.7 0.7 9.5 6.1 8.1 0.7 10.3 6.5 179 7 189 165 8 0 8.5 7.5 06/06/2006 23:20:00 7.3 0.5 8.8 5.7 7.1 0.5 8.4 5.7 7.4 0.6 9.1 5.7 163 8 162 165 7.7 0 8 7.3 06/06/2006 23:30:00 7.5 0.7 9.1 5.3 7.2 0.6 8.8 5.3 7.6 0.7 9.1 5.7 168 11 182 165 7.7 0 8 7.3 06/06/2006 23:40:00 8.2 0.6 9.5 6.5 7.8 0.6 9.1 6.5 8.2 0.6 9.5 6.5 174 6 182 165 7.8 0 8.3 7.3 06/06/2006 23:50:00 6.9 0.8 9.1 5.3 6.7 0.8 8.8 4.9 7 0.8 9.5 5.3 172 8 182 165 7.6 0.2 7.8 7 06/07/2006 00:00:00 6.6 0.6 8.4 5.3 6.3 0.6 8 5.3 6.6 0.6 8.4 5.3 167 5 164 165 7.3 0.1 7.8 6.7 06/07/2006 00:10:00 8.2 0.7 9.5 6.1 7.9 0.7 9.1 6.1 8.3 0.7 9.9 6.5 166 10 165 165 7.3 0.2 7.8 6.7 06/07/2006 00:20:00 8 0.5 9.5 6.8 7.7 0.4 8.8 6.5 8 0.5 9.1 6.5 166 11 165 165 7.3 0.1 7.5 6.7 06/07/2006 00:30:00 7.2 0.3 8 6.5 6.9 0.3 7.6 6.1 7.3 0.3 8 6.1 165 13 158 165 7.1 0 7.5 6.7 06/07/2006 00:40:00 7 0.7 9.1 4.9 6.8 0.7 8.8 5.3 7.1 0.7 9.1 5.3 177 10 184 165 7.1 0.1 7.5 6.7 06/07/2006 00:50:00 7.3 0.6 8.8 5.7 7.2 0.6 8.8 5.7 7.4 0.6 8.8 5.7 185 5 185 165 7.1 0 7.3 6.2 06/07/2006 01:00:00 7 0.6 8.4 5.3 6.9 0.6 8.4 5.3 7.2 0.6 8.4 5.3 187 5 187 165 7.1 0 7.3 7 06/07/2006 01:10:00 6.4 0.5 7.6 4.9 6.4 0.5 8 5.3 6.6 0.5 7.6 5.3 193 4 194 165 7.1 0 7.3 7 06/07/2006 01:20:00 6.6 0.5 7.6 4.9 6.6 0.5 7.6 4.9 6.7 0.5 8 5.3 191 4 192 165 7 0.1 7.3 6.7 06/07/2006 01:30:00 6.1 0.9 7.6 4.2 6 0.9 7.6 4.2 6.2 1 8.4 4.2 185 5 190 165 7.1 0 7.3 6.7 06/07/2006 01:40:00 4.4 0.5 5.7 3.4 4.3 0.4 5.3 3.4 4.5 0.4 5.7 3.8 177 6 179 165 6.7 0 7 6.7 06/07/2006 01:50:00 4.5 0.3 5.3 3.8 4.4 0.3 5.3 3.8 4.7 0.3 5.3 3.8 167 11 164 165 6.6 0 7 6.2 06/07/2006 02:00:00 4.7 0.3 5.7 4.2 4.5 0.3 5.3 3.8 4.9 0.3 5.7 3.8 175 3 173 165 6.6 0 6.7 6.2 06/07/2006 02:10:00 4.8 0.3 5.3 3.8 4.7 0.3 5.3 4.2 4.9 0.4 5.7 3.8 177 3 180 165 6.6 0 7 6.2 06/07/2006 02:20:00 4.8 0.3 5.3 4.2 4.7 0.3 5.3 3.8 5 0.3 5.7 4.2 178 2 179 165 6.8 0 7 6.7 06/07/2006 02:30:00 5.1 0.5 6.1 4.2 5.1 0.5 6.1 4.2 5.2 0.4 6.5 4.2 183 4 183 165 6.9 0 7.3 6.7 06/07/2006 02:40:00 5.7 0.5 6.8 4.9 5.7 0.4 6.8 4.9 5.9 0.5 7.6 4.9 183 3 187 165 7.1 0 7.3 7 06/07/2006 02:50:00 5.4 0.3 6.1 4.6 5.4 0.3 6.1 4.6 5.5 0.3 6.1 4.6 178 3 180 165 7.1 0 7.5 7 06/07/2006 03:00:00 5.8 0.4 6.8 4.9 5.7 0.3 6.5 4.9 5.7 0.4 6.8 4.6 176 4 177 165 7 0 7.3 6.7 06/07/2006 03:10:00 6.4 0.5 7.6 5.3 6.2 0.4 7.2 5.3 6.4 0.5 7.6 5.3 171 5 169 165 7.1 0 7.5 7 06/07/2006 03:20:00 5.9 0.6 7.2 4.2 5.8 0.5 7.2 4.6 5.9 0.5 7.2 4.6 171 5 167 165 7.2 0 7.3 7 06/07/2006 03:30:00 6.8 0.6 8 5.3 6.6 0.6 8 5.3 6.7 0.5 7.6 5.3 169 12 167 165 7.3 0 7.5 7.3 06/07/2006 03:40:00 6 0.7 8 4.6 5.8 0.6 8.4 4.6 6.1 0.6 8 4.6 166 7 179 165 7.3 0 7.5 7.3 06/07/2006 03:50:00 6.7 0.8 8.8 4.6 6.6 0.7 8.4 4.2 6.7 0.7 8.4 4.6 161 8 165 165 7.3 0 7.8 7.3 06/07/2006 04:00:00 6.5 0.7 8 4.9 6.4 0.6 7.6 4.6 6.5 0.6 8 4.9 164 12 163 165 7.4 0 7.5 7.3 06/07/2006 04:10:00 7.3 0.5 8.8 6.1 7.1 0.4 8 6.1 7.3 0.6 8.8 5.7 165 5 168 165 7.5 0 7.8 7.5 06/07/2006 04:20:00 7.1 0.6 8.8 5.3 7 0.5 8.4 5.7 7.3 0.6 8.8 5.3 167 3 165 165 7.6 0 7.8 7.5 06/07/2006 04:30:00 6.2 0.5 7.2 4.9 6.1 0.5 7.2 4.9 6.4 0.5 7.6 4.9 171 5 169 165 7.4 0 7.5 7.3 06/07/2006 04:40:00 6 0.3 6.5 5.3 5.8 0.3 6.5 4.9 6.2 0.3 6.8 4.9 169 7 175 165 7.4 0 7.5 7 06/07/2006 04:50:00 5.5 0.5 6.8 4.6 5.5 0.4 6.8 4.6 5.7 0.5 6.8 4.6 168 3 176 165 7.3 0 7.5 7 06/07/2006 05:00:00 5.8 0.4 6.8 4.6 5.7 0.4 6.8 4.6 6 0.4 6.8 4.6 168 6 164 165 7.2 0 7.5 6.7 06/07/2006 05:10:00 4.7 0.6 6.5 3.8 4.6 0.5 6.1 3.4 4.9 0.6 6.5 3.8 166 9 170 165 6.9 0.1 7.3 6.2 06/07/2006 05:20:00 5.1 0.4 6.5 4.2 5.1 0.4 6.1 4.2 5.3 0.4 6.1 4.2 170 5 173 165 6.7 0 7 6.2 06/07/2006 05:30:00 4.7 0.3 5.3 4.2 4.7 0.3 5.3 3.8 5 0.3 5.7 4.2 174 4 171 165 6.6 0 7 6 06/07/2006 05:40:00 4 0.4 5.3 3.4 4 0.4 5.3 3.4 4.2 0.4 5.3 3.8 171 4 173 165 6.7 0 7 6.2 06/07/2006 05:50:00 3.6 0.2 4.2 3 3.6 0.2 4.2 3 3.9 0.2 4.6 3 170 5 178 165 6.7 0 6.7 6.2 06/07/2006 06:00:00 3.2 0.5 4.2 1.9 3.3 0.4 4.2 1.9 3.4 0.5 4.2 2.3 166 4 169 165 6.7 0 7 6.2 06/07/2006 06:10:00 3.7 0.6 4.9 1.9 3.8 0.6 4.9 2.3 3.9 0.6 4.9 2.3 156 5 152 165 6.8 0.1 7 6.2 06/07/2006 06:20:00 3.9 0.3 4.9 3 4 0.3 4.9 3 4.2 0.3 5.3 3.4 156 6 160 165 6.7 0 7 6.2 06/07/2006 06:30:00 3.8 0.3 4.6 3 4 0.3 4.6 3.4 4.1 0.3 4.9 3 155 4 155 165 6.9 0 7.3 6.5 06/07/2006 06:40:00 5.2 1 7.6 3.8 5.3 1 7.6 3.8 5.3 0.9 8 3.8 146 7 133 165 6.9 0 7.3 6.7 06/07/2006 06:50:00 6.8 0.7 8.4 4.9 6.9 0.7 8.4 5.3 6.9 0.7 8.4 4.9 146 8 140 165 6.9 0 7.3 7 06/07/2006 07:00:00 6 0.8 7.6 4.2 6 0.8 7.6 4.2 6.2 0.8 7.6 4.2 148 6 148 165 7.1 0 7.3 7 06/07/2006 07:10:00 3.5 0.4 4.9 2.6 3.6 0.4 5.3 2.6 3.8 0.3 5.3 3 160 10 141 165 7.1 0 7.3 7 06/07/2006 07:20:00 4.2 0.8 5.7 2.3 4.3 0.8 6.1 2.6 4.4 0.7 6.1 2.6 149 10 128 165 7.2 0 7.3 7.3 06/07/2006 07:30:00 5.3 0.6 6.5 3.8 5.4 0.6 6.8 4.2 5.5 0.6 6.8 3.8 146 5 145 165 7.2 0 7.8 7.3 06/07/2006 07:40:00 5.2 0.5 6.1 4.2 5.3 0.5 6.1 4.2 5.4 0.5 6.5 4.2 148 5 145 165 7.4 0 7.8 7.3 06/07/2006 07:50:00 5.8 0.4 6.8 4.6 5.8 0.4 6.8 4.9 5.9 0.4 6.8 4.6 152 5 146 165 7.3 0 7.5 7 06/07/2006 08:00:00 4.8 0.7 6.5 3 4.8 0.7 6.5 3 4.9 0.7 6.5 3 159 5 150 165 7.2 0 7.5 7 06/07/2006 08:10:00 4.5 0.5 5.7 3 4.6 0.6 6.1 3 4.7 0.5 6.1 3.4 156 5 163 165 8 0.1 8.5 7.5 06/07/2006 08:20:00 4.8 0.5 6.1 3.8 4.8 0.5 6.1 3.4 5 0.6 6.5 3 159 9 172 165 8 0.1 8.3 7.8 06/07/2006 08:30:00 6.3 0.6 8 4.9 6.2 0.6 8.4 4.9 6.4 0.7 8 4.9 168 6 165 165 7.9 0 8 7.8 06/07/2006 08:40:00 7.7 0.5 8.8 5.7 7.5 0.5 8.8 5.7 7.9 0.6 9.5 5.7 167 7 165 165 7.7 0 8 7.5 06/07/2006 08:50:00 8.3 0.6 9.5 6.5 8 0.6 9.1 6.5 8.6 0.7 9.9 6.5 172 9 175 165 7.5 0.1 7.8 7.3 06/07/2006 09:00:00 7.9 0.7 9.1 6.5 7.7 0.6 9.1 6.5 8.1 0.7 9.9 6.1 174 5 167 165 7.3 0 7.5 7.3 06/07/2006 09:10:00 6.4 0.8 8.4 4.9 6.3 0.8 8 4.9 6.7 0.8 8.4 4.9 176 5 174 165 7.3 0 7.8 7.3 06/07/2006 09:20:00 5.5 0.6 7.2 3.8 5.4 0.5 6.8 3.8 5.8 0.6 7.2 4.2 178 7 184 165 7.7 0.2 8 7.3 06/07/2006 09:30:00 5.7 0.5 6.8 4.2 5.7 0.5 7.2 4.6 5.8 0.5 7.2 4.6 169 6 172 165 8.1 0 8.5 7.8 06/07/2006 09:40:00 6.2 0.7 8 4.6 6.2 0.7 8.4 4.6 6.4 0.7 8 4.6 167 9 169 165 8.2 0.1 8.5 7.5 06/07/2006 09:50:00 6.6 0.6 8 4.9 6.5 0.5 8.4 5.3 6.8 0.6 8 5.3 164 10 163 165 8.1 0.2 8.5 7.5 06/07/2006 10:00:00 5.8 0.5 7.6 4.6 5.8 0.5 7.2 4.9 5.9 0.5 6.8 4.6 159 5 162 165 8.1 0.1 8.5 7.5 06/07/2006 10:10:00 5.4 0.5 6.8 4.2 5.4 0.5 6.8 4.2 5.5 0.5 6.8 4.2 152 7 156 165 8.1 0.1 8.5 7.8 06/07/2006 10:20:00 5.9 0.5 7.6 4.9 5.9 0.5 7.6 4.6 5.9 0.4 6.8 4.6 154 6 145 165 8.2 0.2 8.8 7.5 06/07/2006 10:30:00 6.3 0.3 7.2 5.3 6.2 0.3 7.2 5.3 6.5 0.4 7.6 5.7 170 5 165 165 7.9 0.2 8.3 7.3 06/07/2006 10:40:00 8.1 0.7 10.3 6.5 7.9 0.7 9.5 6.5 8.4 0.7 10.3 6.8 173 5 172 165 7.4 0.3 8 6.7 06/07/2006 10:50:00 6.6 0.9 8.8 4.6 6.4 0.9 8.4 4.2 6.7 1 9.1 4.9 168 7 171 165 7.4 0.1 7.8 6.7 06/07/2006 11:00:00 5.8 0.4 7.2 4.9 5.7 0.4 6.8 4.6 5.9 0.4 6.8 4.6 157 3 153 165 7.9 0.1 8.3 7.5 06/07/2006 11:10:00 7.1 1.8 13.7 5.3 7 1.8 13.3 5.3 7.1 1.7 13 4.9 151 7 153 165 7.8 0 8.3 7.3 06/07/2006 11:20:00 10.1 0.9 12.2 7.6 10.1 0.9 12.2 8 10.1 1 12.2 7.2 150 4 158 165 7.2 0.2 8 7 06/07/2006 11:30:00 10.7 0.7 13 9.1 10.7 0.7 13 8.8 10.7 0.7 13 8 151 4 153 165 7.3 0.1 7.5 6.7 06/07/2006 11:40:00 7.8 0.9 10.3 5.7 7.8 0.8 10.3 5.7 7.9 1 10.3 5.7 157 6 146 165 7.4 0 7.8 7.5 06/07/2006 11:50:00 7.2 0.5 8.4 5.7 7.1 0.5 8 5.3 7.2 0.6 8.4 5.7 162 10 152 165 7.4 0 7.8 7.3 06/07/2006 12:00:00 7.1 0.5 8.4 5.3 6.9 0.5 8 5.3 7.2 0.5 8.4 5.3 163 6 165 165 7.4 0.1 7.8 7.3 06/07/2006 12:10:00 6.9 0.5 8.4 5.7 6.8 0.5 8 5.3 7 0.5 8.4 5.7 159 5 156 165 7.8 0.1 8 7.5 06/07/2006 12:20:00 8.6 1.1 10.7 6.5 8.6 1.1 10.7 6.5 8.6 1.1 11.1 6.5 152 5 142 165 7.6 0 7.8 7.5 06/07/2006 12:30:00 10.2 0.8 11.8 7.6 10.2 0.8 12.2 7.2 9.9 1 11.8 7.6 146 5 144 165 7.5 0 8 7.5 06/07/2006 12:40:00 10.7 0.6 12.2 8.8 10.6 0.6 12.2 8.8 10.8 0.7 12.2 8.4 150 3 151 165 7.4 0 7.8 7.5 06/07/2006 12:50:00 10.5 0.6 11.8 8.4 10.5 0.6 11.5 8.8 10.5 0.8 11.8 7.2 150 4 148 165 7.5 0.1 7.8 7.3 06/07/2006 13:00:00 9.9 0.4 10.7 8.4 9.8 0.4 10.7 8.4 9.9 0.5 11.1 7.6 148 3 140 165 7.4 0 7.5 7.3 06/07/2006 13:10:00 9.3 0.5 10.7 7.6 9.3 0.5 10.3 8 9.3 0.6 10.7 7.2 149 3 143 165 7.4 0 7.5 7.3 06/07/2006 13:20:00 9 0.5 10.3 7.6 9 0.5 10.3 7.2 9 0.6 10.3 7.2 149 3 145 165 7.4 0 7.5 7.3 06/07/2006 13:30:00 8.8 0.5 10.3 7.2 8.8 0.6 10.3 7.6 8.8 0.6 10.3 6.5 152 4 145 165 7.3 0 7.5 7 06/07/2006 13:40:00 8.4 0.6 9.5 6.5 8.4 0.6 9.5 6.5 8.3 0.6 9.5 6.5 153 4 153 165 7.4 0 7.5 7 06/07/2006 13:50:00 10 1 12.2 8 10.1 1 11.8 7.6 10.1 1 11.8 7.2 152 4 151 165 7.4 0 7.8 7.3 06/07/2006 14:00:00 11.3 0.8 13.7 9.5 11.3 0.8 13.7 8.8 11.2 1 13.7 8 152 4 153 165 7.4 0 7.5 7 06/07/2006 14:10:00 8.9 1.2 12.2 6.5 8.8 1.2 12.6 6.5 9 1.2 13 6.8 155 4 159 165 7.3 0 7.5 7 06/07/2006 14:20:00 7.8 0.8 9.9 6.5 7.9 0.7 9.9 6.5 7.8 0.8 9.9 6.5 152 4 160 165 7.5 0 7.8 7.3 06/07/2006 14:30:00 9.2 0.9 10.7 7.2 9.2 0.8 11.1 7.2 9 0.9 11.1 6.8 151 5 155 165 7.4 0 7.5 7.3 06/07/2006 14:40:00 9.7 0.6 11.1 8 9.6 0.6 11.1 8 9.7 0.6 11.1 7.6 149 4 154 165 7.4 0.1 8 7 06/07/2006 14:50:00 9.1 0.5 10.7 7.6 9 0.5 10.3 7.6 9 0.6 10.7 7.6 151 3 150 165 7.4 0 8 7.3 06/07/2006 15:00:00 10 0.7 11.5 8 10 0.6 11.1 8 10.1 0.8 11.5 7.2 149 3 145 165 7.3 0 7.5 7 06/07/2006 15:10:00 9.2 0.7 11.1 7.6 9.2 0.7 11.1 7.2 9.2 0.8 11.1 7.2 151 3 145 165 7.4 0 7.5 7 06/07/2006 15:20:00 8.3 0.5 9.5 6.8 8.4 0.5 9.5 7.2 8.5 0.5 9.5 6.5 152 4 150 165 7.4 0 7.5 7 06/07/2006 15:30:00 8.7 0.4 9.9 7.2 8.8 0.4 9.9 7.6 8.9 0.5 9.9 7.2 153 4 147 165 7.1 0 7.3 6.7 06/07/2006 15:40:00 7.6 0.5 8.8 6.1 7.6 0.5 8.8 6.1 7.7 0.6 9.1 6.1 155 4 156 165 7.2 0 7.3 6.7 06/07/2006 15:50:00 9.7 1.5 12.2 6.5 9.8 1.5 11.8 6.5 9.4 1.6 11.8 5.7 148 6 155 165 7.3 0 7.5 7 06/07/2006 16:00:00 9.9 0.9 11.8 6.8 9.9 0.8 11.5 7.2 9.7 1 11.5 6.5 146 5 148 165 7.4 0 7.5 7.3 06/07/2006 16:10:00 10.2 0.8 11.8 7.6 10.1 0.8 11.8 8 10 1 12.2 7.2 148 4 145 165 7.4 0 7.5 7.3 06/07/2006 16:20:00 10.3 0.7 11.8 8.4 10.3 0.6 11.8 8.4 10.3 0.7 11.8 7.6 145 4 143 165 7.5 0 7.8 7.5 06/07/2006 16:30:00 10.3 0.6 12.2 8.8 10.3 0.6 12.2 8.8 10.3 0.6 11.8 8.8 145 4 149 165 7.5 0 7.8 7.5 06/07/2006 16:40:00 9.7 0.7 11.1 7.6 9.6 0.7 11.1 7.6 9.6 0.8 11.5 7.6 145 4 142 165 7.4 0 7.8 7.5 06/07/2006 16:50:00 9 0.8 10.7 6.5 9 0.8 10.7 6.1 8.9 0.8 11.1 6.8 146 6 145 165 7.4 0 7.8 7.5 06/07/2006 17:00:00 9.8 0.7 11.1 8 9.8 0.7 11.1 8 9.8 0.8 11.5 6.8 146 4 145 165 7.6 0 7.8 7.5 06/07/2006 17:10:00 10 0.6 11.5 8.4 9.9 0.6 11.5 8.4 9.9 0.7 11.8 7.6 147 5 148 165 7.6 0 7.8 7.5 06/07/2006 17:20:00 9.6 0.7 11.8 7.2 9.5 0.7 11.5 7.2 9.5 0.7 11.5 7.2 146 5 159 165 7.6 0 7.8 7.5 06/07/2006 17:30:00 9.3 0.7 11.1 7.6 9.3 0.7 11.1 7.6 9.1 0.9 11.5 6.1 144 6 140 165 7.6 0 7.8 7.5 06/07/2006 17:40:00 9.8 1 12.6 6.5 9.9 1.1 13 6.5 9.6 1 12.2 6.8 141 6 134 165 7.6 0 8.3 7.5 06/07/2006 17:50:00 10.6 0.9 13 8 10.5 0.9 13 8.4 10.6 0.9 13 8 147 5 147 165 7.7 0 7.8 7.5 06/07/2006 18:00:00 11.7 0.6 13 9.5 11.7 0.6 13 9.5 11.6 0.7 13 9.1 148 4 137 165 7.7 0 7.8 7.5 06/07/2006 18:10:00 11.1 0.6 12.6 9.1 11 0.6 12.6 9.1 11.1 0.7 12.6 8.4 149 3 149 165 7.5 0 8 7.3 06/07/2006 18:20:00 12.1 0.7 13.7 9.9 12.2 0.7 14.1 9.9 12.1 0.8 14.1 9.9 144 4 143 165 7.6 0 7.8 7.3 06/07/2006 18:30:00 11.8 0.7 13.3 9.9 11.8 0.7 13.3 9.9 11.8 0.8 13.7 9.5 147 3 143 165 7.6 0 8 7.3 06/07/2006 18:40:00 11.8 0.7 13.3 9.9 11.7 0.7 13.3 9.5 11.8 0.8 14.1 9.5 148 3 149 165 7.6 0.1 8.3 7 06/07/2006 18:50:00 11 0.7 13 8.8 11 0.7 13 9.1 10.8 0.8 13 8 145 5 148 165 7.6 0 7.8 7.3 06/07/2006 19:00:00 11.5 0.8 13.3 8.8 11.5 0.8 13 9.1 11.5 0.9 13.3 8.8 145 4 147 165 7.5 0.1 7.8 7.3 06/07/2006 19:10:00 11.8 0.7 13.7 9.5 11.7 0.7 13.3 9.5 11.7 0.9 14.1 8.8 144 4 145 165 7.6 0 8 7.3 06/07/2006 19:20:00 12.7 0.6 14.5 10.3 12.7 0.6 14.5 9.9 12.5 0.8 14.5 9.1 144 4 144 165 7.5 0.1 7.8 7.3 06/07/2006 19:30:00 11.9 0.9 14.1 9.1 11.9 0.9 14.1 9.5 11.7 1 14.1 9.1 144 4 139 165 7.4 0.1 8 7.3 06/07/2006 19:40:00 12.2 0.8 14.5 9.9 12.3 0.8 14.1 9.9 12.3 1 14.5 9.9 146 4 145 165 7.4 0 7.8 7.3 06/07/2006 19:50:00 11.2 0.9 13 8 11.2 0.9 13.3 8 11 1.1 13 8 145 7 137 165 7.5 0 7.8 7.3 06/07/2006 20:00:00 10.9 0.9 13.3 9.1 10.9 0.9 13 9.1 10.8 0.9 13.3 8.8 146 5 143 165 7.5 0 7.8 7.3 06/07/2006 20:10:00 12.4 1.1 14.9 9.1 12.4 1.1 14.5 8.8 12.2 1.2 14.9 8 142 6 152 165 7.5 0 7.8 7 06/07/2006 20:20:00 12.1 1.3 14.5 8 12.1 1.3 14.9 8.4 11.9 1.3 14.9 8.4 139 6 133 165 7.5 0 7.8 7.3 06/07/2006 20:30:00 10.5 0.9 13 8 10.5 0.9 13.3 8.4 10.3 1 12.6 8 140 7 136 165 7.4 0 7.8 7.5 06/07/2006 20:40:00 10.8 0.9 12.2 7.6 10.9 0.8 12.6 8 10.7 1 13 7.6 141 5 137 165 7.4 0 7.5 7.3 06/07/2006 20:50:00 11.3 0.7 13.3 8.4 11.5 0.8 13.7 8.4 11.2 0.8 13.3 9.1 141 5 147 165 7.4 0 7.5 7.3 06/07/2006 21:00:00 11.8 1.2 14.1 8.4 11.9 1.2 14.1 8 11.6 1.2 14.1 7.2 141 6 143 165 7.4 0 7.5 7.3 06/07/2006 21:10:00 12.3 1.1 14.9 9.5 12.4 1.2 14.9 9.5 12.4 1.2 15.3 8.4 140 6 133 165 7.3 0 7.5 7.3 06/07/2006 21:20:00 11.5 1 13.7 8.4 11.6 1.1 14.1 8 11.4 1.2 13.7 7.6 139 7 145 165 7.4 0 7.5 7.3 06/07/2006 21:30:00 11.6 0.8 14.1 9.1 11.7 0.8 14.1 9.5 11.5 1 13.3 8.4 140 6 142 165 7.3 0 7.8 7 06/07/2006 21:40:00 11.7 0.8 13.7 9.5 11.7 0.8 13.7 9.5 11.7 1 14.1 9.1 140 5 143 165 7.1 0 7.5 7 06/07/2006 21:50:00 12.2 1 14.9 9.1 12.2 1 14.9 9.1 12.2 1.1 14.9 8.8 141 5 133 165 7.1 0 7.3 7 06/07/2006 22:00:00 12.4 1.3 14.9 9.1 12.4 1.3 15.3 9.1 12.2 1.5 15.3 8.8 141 6 139 165 7.1 0 7.5 7 06/07/2006 22:10:00 12.9 1.1 14.9 9.9 12.9 1.1 14.9 9.5 12.8 1.3 15.3 9.1 149 3 151 165 7.1 0.1 7.3 7 06/07/2006 22:20:00 12.3 1 13.7 10.3 12.3 1 14.1 9.9 12.4 1.2 14.5 9.1 149 4 149 165 7 0 7.3 7 06/07/2006 22:30:00 12.3 0.7 14.1 9.5 12.3 0.7 14.1 10.3 12.2 0.8 13.7 9.9 146 4 149 165 6.8 0 7 6.7 06/07/2006 22:40:00 11.9 0.6 13.3 9.5 11.9 0.6 13.3 9.5 12 0.7 13.7 9.1 144 4 137 165 6.7 0 7 6.2 06/07/2006 22:50:00 11.3 0.6 13.3 9.5 11.2 0.7 13 9.5 11.4 0.7 13 9.5 150 3 152 165 7.1 0 7.3 6.5 06/07/2006 23:00:00 11 0.7 12.6 9.1 10.9 0.7 12.6 9.1 10.9 0.8 13 8.8 150 4 153 165 7.2 0 7.5 6.7 06/07/2006 23:10:00 12 1 14.1 9.5 12.1 1 14.5 9.1 11.9 1.1 14.1 9.5 147 5 145 165 7.3 0 7.5 6.7 06/07/2006 23:20:00 12.6 0.8 14.5 10.3 12.7 0.8 14.5 10.3 12.6 0.9 14.9 10.7 146 4 144 165 7.1 0 7.3 6.7 06/07/2006 23:30:00 12.8 0.8 15.3 10.7 12.9 0.8 15.6 10.7 12.9 0.8 14.5 10.3 145 5 147 165 7 0.1 7.3 6.2 06/07/2006 23:40:00 12.8 0.8 14.5 10.7 12.9 0.8 14.1 10.7 12.9 0.8 14.5 10.3 146 3 139 165 6.9 0.1 7 6.2 06/07/2006 23:50:00 12.4 1 15.3 9.9 12.5 1 15.3 9.9 12.3 1.1 14.9 9.5 146 4 145 165 6.9 0.1 7.3 6.2 06/08/2006 00:00:00 13.8 1.1 15.6 10.3 13.9 1.1 15.6 10.3 13.8 1.2 16.1 9.5 145 4 136 165 7.1 0 7.3 6.5 06/08/2006 00:10:00 11.8 0.8 13.7 9.9 11.8 0.9 13.7 9.5 11.7 0.9 13.7 9.1 145 4 142 165 7.1 0 7.3 6.5 06/08/2006 00:20:00 11.2 0.8 13 8.8 11.2 0.8 13 9.1 11.2 0.9 13.3 8.4 146 4 147 165 6.9 0.1 7.3 6.2 06/08/2006 00:30:00 10.8 0.7 12.6 9.1 10.9 0.6 12.6 9.1 10.7 0.7 12.6 8.8 142 4 146 165 6.9 0.1 7 6.2 06/08/2006 00:40:00 10.3 0.7 12.2 8.4 10.3 0.7 12.2 8.4 10.3 0.8 12.2 8.4 142 5 133 165 6.9 0.1 7 6.2 06/08/2006 00:50:00 9.5 0.9 11.8 7.2 9.5 0.8 11.8 6.5 9.4 0.9 11.5 6.8 145 6 145 165 7 0 7.3 6.5 06/08/2006 01:00:00 10.3 1 13 7.2 10.4 1 12.6 7.6 10.2 1.1 12.6 7.6 138 6 140 165 7 0 7.5 7 06/08/2006 01:10:00 9.6 0.8 11.8 7.6 9.6 0.8 11.8 7.6 9.4 0.9 11.8 6.8 140 7 133 165 7.1 0 7.3 7 06/08/2006 01:20:00 10.1 0.9 13 8 10.1 0.9 13 8 9.9 1 12.6 6.8 143 6 138 165 7.1 0 7.3 7 06/08/2006 01:30:00 9.8 0.7 11.5 6.8 9.8 0.7 11.8 7.6 9.6 0.7 11.1 7.6 138 7 139 165 7.1 0 7.3 7 06/08/2006 01:40:00 10.1 1.1 13.3 6.8 10.1 1.1 13.3 7.2 9.9 1.2 13.7 6.8 141 8 127 165 7.1 0 7.3 7 06/08/2006 01:50:00 11 1.1 13.3 7.2 11 1.1 13.3 7.2 10.9 1.3 14.1 7.6 140 7 141 165 7.3 0 7.3 7.3 06/08/2006 02:00:00 12.3 1.3 15.6 9.1 12.4 1.4 15.6 9.1 12.1 1.4 15.3 9.1 141 5 139 165 7.2 0 7.5 7.3 06/08/2006 02:10:00 12.1 1.3 14.5 8.8 12.2 1.3 14.9 9.1 11.8 1.5 15.3 8.4 140 6 138 165 7.2 0 7.3 7.3 06/08/2006 02:20:00 12.2 1.2 14.9 8.8 12.2 1.2 14.9 8.8 12 1.3 15.3 8.4 142 6 150 165 7.2 0 7.3 7.3 06/08/2006 02:30:00 12.1 1 14.5 9.5 12.2 1 14.5 9.1 11.9 1.3 14.5 7.6 141 7 144 165 7.2 0 7.3 7.3 06/08/2006 02:40:00 11.8 1.4 14.9 8 11.8 1.4 14.5 7.2 11.6 1.5 14.1 7.6 140 6 147 165 7.2 0 7.3 7 06/08/2006 02:50:00 12.5 1.2 15.3 9.1 12.6 1.2 15.3 9.5 12.4 1.3 14.9 8.8 141 5 143 165 7.1 0 7.3 7.3 06/08/2006 03:00:00 11.8 1.2 14.5 8.8 11.8 1.2 14.9 8.8 11.7 1.3 14.5 7.6 144 6 144 165 7.2 0 7.3 7.3 06/08/2006 03:10:00 10.2 0.8 12.6 7.6 10.2 0.8 12.6 7.6 10 0.8 12.6 7.6 142 6 139 165 7.3 0 7.3 6.7 06/08/2006 03:20:00 12.8 1.4 16.1 9.5 12.8 1.4 16.4 9.9 12.5 1.5 16.1 9.1 143 6 133 165 7.2 0 7.3 6.7 06/08/2006 03:30:00 11.3 1.1 14.1 8.4 11.4 1 14.5 8.4 11.2 1.2 13.7 6.8 140 8 145 165 7.2 0 7.3 6.7 06/08/2006 03:40:00 11.6 1.2 14.1 7.6 11.7 1.2 14.5 8 11.4 1.4 14.5 8 138 7 136 165 7.3 0 7.3 7.3 06/08/2006 03:50:00 12 1 14.5 8.8 12 1 14.5 9.1 11.7 1.1 14.9 8.8 138 7 137 165 7.3 0 7.5 6.7 06/08/2006 04:00:00 11.8 1.5 15.6 8.4 11.9 1.5 16.1 8.4 11.5 1.5 16.1 8.4 138 7 133 165 7.4 0.1 7.8 6.7 06/08/2006 04:10:00 11.1 1 13.3 7.6 11.1 1 13.7 8.4 10.8 1.2 13.7 8 135 6 122 165 7.4 0.1 7.5 6.7 06/08/2006 04:20:00 12.1 1.3 15.3 8.8 12.1 1.4 15.3 8.4 11.7 1.4 15.3 8.4 135 7 126 165 7.4 0.1 7.5 6.7 06/08/2006 04:30:00 10.8 1.2 14.9 8.4 10.8 1.2 14.9 8.4 10.7 1.2 14.5 7.6 139 8 146 165 7.4 0.1 7.5 7 06/08/2006 04:40:00 10.6 1.2 13.7 7.6 10.6 1.2 13.7 8 10.3 1.2 13.7 7.6 132 7 128 165 7.4 0.1 7.5 7 06/08/2006 04:50:00 11.5 1.3 14.9 8.8 11.5 1.3 14.9 8.4 11 1.3 14.9 7.6 136 8 128 165 7.5 0 7.8 7 06/08/2006 05:00:00 11.8 1.3 16.1 8.8 11.8 1.3 16.4 8.8 11.4 1.3 14.9 7.6 137 7 132 165 7.6 0 8 7.3 06/08/2006 05:10:00 11.5 1.1 14.9 8.8 11.5 1.1 14.9 8 11.2 1.2 14.1 8 138 8 151 165 7.6 0 7.8 7.3 06/08/2006 05:20:00 10.1 1.3 14.1 7.2 10.1 1.3 13.7 7.2 10 1.3 13.7 7.2 140 6 136 165 7.6 0 7.8 7.3 06/08/2006 05:30:00 11.5 1.3 15.3 8.4 11.5 1.3 15.3 8.4 11.3 1.5 14.9 7.2 133 8 131 165 7.6 0 7.8 7.5 06/08/2006 05:40:00 10.9 1.1 14.1 8.4 10.9 1.1 14.5 8.8 10.7 1.2 13.7 7.6 142 8 129 165 7.6 0 8 7.5 06/08/2006 05:50:00 10.8 1.9 15.3 6.8 10.9 1.9 15.3 6.5 10.4 1.7 14.5 6.5 135 13 149 165 7.6 0 7.8 7.5 06/08/2006 06:00:00 10.9 1 13.3 7.6 10.9 1 13.3 7.6 10.7 1.1 13.3 8 140 8 141 165 7.6 0 7.8 7.5 06/08/2006 06:10:00 11.2 1.2 14.9 7.6 11.2 1.2 14.9 8 11 1.3 14.9 8 142 8 139 165 7.6 0 8.3 7.5 06/08/2006 06:20:00 10 0.9 12.2 7.6 10 0.9 12.2 7.6 10 1 12.6 7.6 145 7 142 165 7.7 0 7.8 7.5 06/08/2006 06:30:00 9.6 1.4 13 7.2 9.6 1.4 13 7.2 9.6 1.3 12.6 6.8 147 7 158 165 7.6 0 7.8 7.5 06/08/2006 06:40:00 8.6 1.9 13.7 4.9 8.8 2 13.7 4.6 8.2 1.7 13.3 4.9 125 12 114 165 7.8 0 7.8 7.5 06/08/2006 06:50:00 12.2 1.7 16.8 9.1 12.4 1.7 17.2 9.1 11.9 1.7 16.1 8.4 125 7 126 165 7.7 0 7.8 7.5 06/08/2006 07:00:00 9.4 1.3 12.6 6.1 9.5 1.3 13 5.7 9.1 1.2 11.8 6.5 124 9 133 165 7.7 0 8 7.5 06/08/2006 07:10:00 11.5 1.5 14.5 7.6 11.7 1.4 14.9 7.2 11.1 1.6 15.3 7.2 119 6 121 165 7.7 0 8.3 7.5 06/08/2006 07:20:00 12 1.2 14.5 7.6 12.2 1.3 14.9 7.2 11.5 1.3 14.9 6.5 121 7 127 165 7.6 0 7.8 7.5 06/08/2006 07:30:00 11.7 1.7 16.1 7.2 11.9 1.7 16.4 7.2 11.4 1.7 14.5 6.8 121 7 118 165 7.6 0 7.8 7.5 06/08/2006 07:40:00 11.8 1.3 15.3 8.8 12 1.3 15.3 8.8 11.3 1.3 15.6 8.4 116 7 113 165 7.6 0 7.8 7.5 06/08/2006 07:50:00 12.7 2.1 18.3 7.6 12.9 2.2 18.7 7.6 12.3 2.2 18.7 8 122 8 118 165 7.6 0 7.8 7 06/08/2006 08:00:00 14.6 1.9 19.5 10.3 14.8 1.9 19.9 10.7 14 2.1 19.1 8.8 121 8 121 165 7.5 0.1 7.8 7 06/08/2006 08:10:00 14 1.7 18.7 10.3 14.2 1.7 19.1 10.3 13.7 1.7 18.3 8.8 132 8 125 165 7.4 0.1 7.5 7 06/08/2006 08:20:00 12.7 1.2 16.1 9.5 12.8 1.2 16.1 9.5 12.6 1.3 15.6 9.1 137 6 141 165 7.4 0.1 7.5 7 06/08/2006 08:30:00 12.5 1.6 17.2 9.1 12.6 1.6 17.2 8.8 12.1 1.6 16.4 8 127 10 125 165 7.4 0.1 7.5 6.7 06/08/2006 08:40:00 13.2 1.2 16.1 10.3 13.4 1.2 16.8 10.7 13 1.3 16.8 9.1 126 5 127 165 7.3 0 7.5 6.7 06/08/2006 08:50:00 14.1 1 16.8 11.1 14.3 1.1 16.8 11.5 13.9 1.2 16.8 11.1 125 6 121 165 7.3 0 7.5 7 06/08/2006 09:00:00 13.4 1.3 17.6 9.1 13.7 1.3 17.9 9.5 13.2 1.3 17.2 8.8 124 6 111 165 7.3 0 7.8 7 06/08/2006 09:10:00 13.4 1.1 16.8 10.3 13.5 1.1 17.2 10.3 13 1.2 17.6 9.1 126 7 118 165 7.4 0.1 7.5 6.7 06/08/2006 09:20:00 12.5 1.5 17.2 8.8 12.7 1.5 17.6 8.8 12.2 1.6 17.6 8.4 124 7 133 165 7.3 0.1 7.5 7 06/08/2006 09:30:00 13.3 1.1 16.8 10.3 13.5 1.1 16.8 10.7 12.9 1.3 16.4 9.5 122 5 130 165 7.3 0 7.8 6.7 06/08/2006 09:40:00 12.5 1.1 15.6 9.9 12.7 1.1 15.6 9.9 12.1 1.2 15.6 8.8 123 5 123 165 7.3 0 7.5 6.7 06/08/2006 09:50:00 11.9 1.1 15.6 10.3 12.2 1 15.6 10.3 11.6 1.1 14.5 8.8 123 5 124 165 7.3 0 7.5 7 06/08/2006 10:00:00 12.5 1.2 15.6 8.8 12.7 1.2 16.1 8.8 12.3 1.3 15.6 8 125 5 129 165 7.3 0 7.3 7 06/08/2006 10:10:00 11.9 1.5 16.8 9.1 12.1 1.6 16.4 9.5 11.5 1.5 16.8 8.4 122 6 116 165 7.2 0 7.3 7.3 06/08/2006 10:20:00 12.1 1.4 16.4 8.8 12.4 1.5 17.2 9.1 11.7 1.5 17.2 8.4 120 7 110 165 7.2 0 7.3 7 06/08/2006 10:30:00 11.4 1.8 15.3 7.6 11.6 1.8 15.6 7.6 10.9 1.9 15.3 7.2 118 6 106 165 7.3 0 7.5 7.3 06/08/2006 10:40:00 14.2 1.7 17.6 10.7 14.4 1.7 17.9 10.7 13.7 1.9 18.3 9.5 119 7 121 165 7.3 0 7.5 7.3 06/08/2006 10:50:00 13.1 1.7 16.8 9.5 13.3 1.7 17.6 9.1 12.8 1.6 17.2 8.8 124 6 116 165 7.3 0 7.5 7.3 06/08/2006 11:00:00 13.3 1.5 16.8 8 13.5 1.5 17.6 8.4 13 1.5 17.2 9.1 123 8 118 165 7.2 0 7.5 7.3 06/08/2006 11:10:00 13.4 1.3 16.8 9.1 13.6 1.4 17.2 9.5 13.1 1.4 17.2 9.5 126 7 122 165 7.3 0 7.3 7.3 06/08/2006 11:20:00 13.7 1.7 19.1 9.9 13.9 1.7 19.1 9.9 13.2 1.9 19.1 9.1 125 6 133 165 7.3 0 7.5 7.3 06/08/2006 11:30:00 14.4 1.4 17.9 10.7 14.6 1.5 18.3 11.1 14.1 1.7 18.7 9.1 126 6 126 165 7.3 0 7.5 7.3 06/08/2006 11:40:00 13.9 1.3 17.2 10.7 14.1 1.3 17.6 10.7 13.7 1.3 17.6 9.9 125 6 123 165 7.3 0 7.5 7.3 06/08/2006 11:50:00 14.2 1.8 18.7 7.2 14.5 1.9 19.1 6.8 13.9 1.8 18.7 9.1 120 7 106 165 7.4 0 7.5 7.3 06/08/2006 12:00:00 14.9 1.5 18.7 10.3 15.1 1.5 18.7 11.1 13.8 1.7 17.6 9.9 114 6 122 165 7.4 0 7.5 7.3 06/08/2006 12:10:00 14 1.5 17.6 8.4 14.3 1.5 17.6 8.8 13.4 1.6 17.6 8.8 114 6 130 165 7.4 0 7.8 7.3 06/08/2006 12:20:00 14.8 1.3 18.3 10.3 15 1.3 18.7 10.3 13.8 1.5 17.6 9.9 110 6 111 165 7.4 0.1 7.5 7 06/08/2006 12:30:00 15.2 1.6 19.5 9.9 15.4 1.6 19.5 9.9 14.3 1.8 18.3 9.5 104 6 105 165 7.4 0.1 7.5 7 06/08/2006 12:40:00 15.9 1.5 19.5 10.7 16.2 1.5 20.2 11.5 14.9 1.8 19.1 9.9 109 7 103 165 7.4 0.1 7.5 7 06/08/2006 12:50:00 15.2 1.7 19.9 11.1 15.4 1.7 20.2 11.1 14.4 1.7 18.3 9.9 112 7 116 165 7.4 0.1 7.5 7 06/08/2006 13:00:00 15.5 1.5 19.1 11.8 15.8 1.5 19.5 12.2 14.8 1.6 19.1 10.7 111 6 111 165 7.4 0.1 7.5 7 06/08/2006 13:10:00 14.8 1.6 18.7 10.7 15.1 1.6 19.1 11.1 14.2 1.7 18.7 9.1 114 7 111 165 7.4 0.1 7.5 7 06/08/2006 13:20:00 15.6 1.8 21 10.7 15.8 1.9 21.4 11.1 15.1 1.9 20.2 10.3 116 9 111 165 7.4 0.1 7.5 6.7 06/08/2006 13:30:00 14.5 2 20.2 8.8 14.8 2.1 21 9.5 14 2.1 19.9 8.8 115 8 110 165 7.4 0.1 7.5 7 06/08/2006 13:40:00 14.5 1.7 19.1 10.3 14.8 1.7 19.1 10.7 13.8 1.8 18.3 9.1 112 7 111 165 7.4 0.1 7.5 7 06/08/2006 13:50:00 16.2 1.8 23.7 10.3 16.5 1.8 24.4 10.7 15.3 1.9 21.8 10.3 113 7 116 165 7.4 0.1 7.5 6.7 06/08/2006 14:00:00 15 1.5 20.2 11.5 15.2 1.4 19.9 11.5 14.3 1.7 18.7 10.3 113 7 112 165 7.3 0 7.8 6.7 06/08/2006 14:10:00 15.4 1.6 18.7 9.9 15.7 1.7 19.5 10.3 14.7 1.7 18.7 9.9 111 7 112 165 7.2 0 7.5 7 06/08/2006 14:20:00 15.5 2 22.9 11.5 15.7 2.1 23.3 11.5 14.7 2.4 24 9.1 110 6 110 165 7.3 0 7.5 7 06/08/2006 14:30:00 14.9 1.9 20.2 8.4 15.1 2 20.2 8.8 14.1 2.1 19.1 8.8 108 7 107 165 7.4 0.1 7.8 6.7 06/08/2006 14:40:00 17 1.7 22.1 11.1 17.3 1.7 22.6 10.7 16.3 2 22.1 9.9 111 6 115 165 7.3 0 7.5 7.3 06/08/2006 14:50:00 16 1.9 21.4 10.7 16.3 1.9 21.8 11.1 15.1 2 21 9.5 112 6 111 165 7.4 0 7.5 7.3 06/08/2006 15:00:00 16.3 2 22.1 11.1 16.6 2 22.6 11.1 15.5 2.2 21 9.5 114 8 117 165 7.3 0 7.8 7.3 06/08/2006 15:10:00 15.9 1.8 20.6 10.3 16.2 1.8 20.6 9.9 15 1.9 19.5 9.1 114 8 115 165 7.4 0 7.5 7.3 06/08/2006 15:20:00 15.4 2.2 21.8 8.8 15.7 2.3 21 8.4 14.5 2.3 21 8.8 112 7 115 165 7.4 0 7.5 7.3 06/08/2006 15:30:00 17 1.7 21.8 11.1 17.3 1.7 22.1 12.2 16.2 1.9 21 10.3 112 7 117 165 7.4 0 7.5 7.3 06/08/2006 15:40:00 16.9 1.7 22.6 11.8 17.2 1.7 22.9 11.5 16 1.9 21 11.1 113 8 106 165 7.4 0 7.5 7.3 06/08/2006 15:50:00 17.1 2.2 22.1 9.1 17.4 2.2 22.6 9.1 16.2 2.2 22.6 9.1 118 8 130 165 7.4 0 7.5 7.3 06/08/2006 16:00:00 17 2.3 23.3 11.1 17.3 2.3 23.7 10.7 16.1 2.4 23.3 9.9 114 7 124 165 7.4 0 7.5 7.5 06/08/2006 16:10:00 17.5 2.3 24 10.7 17.7 2.3 24.8 10.7 16.4 2.1 22.1 11.8 110 7 107 165 7.4 0 7.5 7.5 06/08/2006 16:20:00 17.9 2 24.8 13 18.1 2 25.2 13 16.8 2.1 23.7 11.1 111 6 107 165 7.5 0 7.5 7.5 06/08/2006 16:30:00 18.6 2.1 22.9 13 18.8 2.1 22.9 13 17.5 2.5 23.3 10.3 111 7 119 165 7.5 0 7.8 7.5 06/08/2006 16:40:00 18.2 1.8 22.9 13 18.5 1.7 23.3 13 17.3 1.9 22.6 12.2 111 6 111 165 7.4 0 7.5 7.5 06/08/2006 16:50:00 17.5 1.9 21.8 12.6 17.7 1.9 22.1 12.6 16.5 2.1 21.4 11.5 112 6 114 165 7.4 0.1 7.5 7 06/08/2006 17:00:00 18.2 1.8 22.6 12.6 18.4 1.9 23.3 13 16.9 2.1 22.1 12.2 109 6 102 165 7.4 0.1 7.5 7 06/08/2006 17:10:00 18.5 2.1 24 11.8 18.8 2.1 24 11.8 17.3 2.3 23.7 11.5 109 6 106 165 7.4 0.1 7.5 7 06/08/2006 17:20:00 17.5 2.1 22.9 12.2 17.8 2.2 23.3 11.8 16.4 2.4 22.9 9.9 108 7 111 165 7.5 0 7.5 7 06/08/2006 17:30:00 19.3 2.1 23.7 12.2 19.6 2.1 24 11.8 18.1 2.4 23.7 11.5 106 6 100 165 7.6 0 7.8 7 06/08/2006 17:40:00 17.8 1.9 22.6 11.5 18.1 1.8 23.3 13 16.7 2 22.6 11.8 107 6 116 165 7.6 0 7.8 7 06/08/2006 17:50:00 18.4 2.2 23.7 11.8 18.6 2.2 23.7 11.5 17.1 2.2 23.3 11.1 104 7 108 165 7.6 0 7.8 7 06/08/2006 18:00:00 19.4 1.7 23.7 14.5 19.7 1.7 24.4 13.7 18.4 2 24 12.6 102 6 104 165 7.6 0 7.8 7 06/08/2006 18:10:00 19.8 2.3 25.2 12.6 20.1 2.3 25.6 12.6 18.8 2.6 25.6 11.5 103 7 102 165 7.6 0 7.8 7 06/08/2006 18:20:00 19.5 2.3 25.6 13 19.8 2.3 26 13.3 18.1 2.4 24.8 12.2 101 7 102 165 7.6 0 7.8 7.3 06/08/2006 18:30:00 19.9 2.1 26 14.1 20.3 2.1 26.3 14.9 18.7 2.4 24.8 13 101 6 99 165 7.6 0 7.8 7.3 06/08/2006 18:40:00 19.4 1.9 25.2 14.5 19.7 2 26 14.1 18.1 2.3 25.2 12.6 104 6 99 165 7.6 0 7.8 7.3 06/08/2006 18:50:00 18.5 2 23.7 12.6 18.8 2.1 23.7 13 17 2.2 22.1 9.9 105 6 110 165 7.6 0 7.8 7.3 06/08/2006 19:00:00 19.4 2.4 25.2 12.2 19.7 2.4 25.2 13.3 18.3 2.5 24.8 12.6 106 7 107 165 7.6 0 8 7.3 06/08/2006 19:10:00 19 2 25.2 12.6 19.4 2.1 24.8 13 18 2.2 23.3 11.1 105 6 103 165 7.7 0 7.8 7.5 06/08/2006 19:20:00 18.8 2.6 24.8 9.9 19.1 2.6 25.2 10.3 17.6 2.7 24.4 11.8 106 7 102 165 7.7 0 7.8 7.5 06/08/2006 19:30:00 19.5 2.4 24.4 12.6 19.8 2.4 24.8 14.1 18.4 2.5 25.2 11.1 106 6 102 165 7.8 0 8 7.8 06/08/2006 19:40:00 19.2 2.4 24.8 13 19.4 2.4 25.2 12.2 18 2.6 24 11.5 107 6 105 165 7.8 0 7.8 7.8 06/08/2006 19:50:00 17.6 2.1 22.9 12.6 17.9 2.1 22.9 12.2 16.7 2.2 22.6 10.7 107 7 102 165 7.8 0 7.8 7.8 06/08/2006 20:00:00 18.8 2.3 24 13.3 19.1 2.4 24.4 13.7 17.7 2.4 24.4 12.2 107 7 106 165 7.8 0 8 7.8 06/08/2006 20:10:00 17.7 2.3 22.1 10.3 18 2.4 22.6 11.5 16.6 2.4 22.6 11.1 109 7 106 165 7.8 0 7.8 7.8 06/08/2006 20:20:00 18.8 2.3 25.6 12.2 19.2 2.4 25.6 11.8 17.7 2.5 23.7 10.7 108 6 108 165 7.8 0 7.8 7.8 06/08/2006 20:30:00 18 2.3 23.7 11.5 18.4 2.3 24.4 12.2 16.9 2.3 22.6 11.8 109 8 105 165 7.8 0 8.3 7.8 06/08/2006 20:40:00 18.6 2.2 25.2 11.8 18.9 2.2 25.2 11.8 17.5 2.2 23.3 11.5 109 7 111 165 7.8 0 7.8 7.8 06/08/2006 20:50:00 18.9 1.8 23.3 13.3 19.2 1.9 23.7 13.7 17.5 2.3 23.3 11.1 108 6 114 165 7.8 0 7.8 7.8 06/08/2006 21:00:00 18.2 1.9 22.9 13.7 18.5 1.9 23.3 13.3 17.1 2.1 21.8 11.1 106 7 102 165 7.8 0 8.3 7.8 06/08/2006 21:10:00 18 2 23.3 12.2 18.3 2.1 23.7 13 16.8 2.2 23.3 9.9 108 8 98 165 7.8 0 7.8 7.8 06/08/2006 21:20:00 18.9 1.8 22.9 13.7 19.2 1.7 23.3 13.7 17.8 1.9 22.9 12.6 107 5 106 165 7.8 0 7.8 7.8 06/08/2006 21:30:00 18.1 2.3 23.7 10.7 18.5 2.3 23.7 10.7 17.1 2.4 23.3 9.9 108 7 114 165 7.8 0 7.8 7.3 06/08/2006 21:40:00 18.8 1.7 22.9 13.7 19.1 1.7 22.9 14.9 17.7 1.9 22.6 11.8 106 7 102 165 7.8 0 8 7.3 06/08/2006 21:50:00 17.9 2 22.1 12.2 18.3 2 22.6 13 17 2.1 22.1 11.8 108 6 106 165 7.8 0 7.8 7.3 06/08/2006 22:00:00 17.6 2.3 23.3 10.3 17.9 2.4 23.7 11.1 16.6 2.6 23.3 10.3 108 7 106 165 7.8 0 8 7.3 06/08/2006 22:10:00 18 1.7 22.1 12.6 18.3 1.7 22.1 13.3 17 1.9 22.1 11.8 108 6 104 165 7.8 0 7.8 7.3 06/08/2006 22:20:00 18.4 1.6 21.8 11.8 18.8 1.6 22.1 12.2 17.3 1.9 21.4 12.2 108 6 104 165 7.8 0 7.8 7.3 06/08/2006 22:30:00 18 2.2 22.9 11.5 18.3 2.3 22.9 11.5 16.8 2.2 22.1 10.7 107 7 108 165 7.8 0 7.8 7.3 06/08/2006 22:40:00 18.3 1.7 21.8 13.3 18.6 1.7 21.8 13.3 17.3 1.9 22.1 11.1 107 6 103 165 7.8 0 8 7.3 06/08/2006 22:50:00 17.3 1.9 21.8 12.6 17.6 1.9 22.1 13 16.2 2 20.6 11.5 107 6 118 165 7.8 0 8 7.3 06/08/2006 23:00:00 17.7 1.7 21.8 13 18 1.7 22.6 13 16.7 1.9 21.4 11.1 107 6 99 165 7.8 0 8 7.3 06/08/2006 23:10:00 17 1.8 21 10.7 17.3 1.9 21.8 10.7 15.7 2 21 9.9 107 7 111 165 7.8 0 8 7.3 06/08/2006 23:20:00 17.4 1.8 21.4 11.8 17.8 1.8 22.1 12.2 16.5 2.2 21 11.1 106 6 109 165 7.8 0 8 7.3 06/08/2006 23:30:00 17.1 2 21.8 11.8 17.4 2 22.1 11.8 15.9 2 21 11.1 104 6 107 165 7.8 0 8 7.3 06/08/2006 23:40:00 16.8 1.8 20.6 12.2 17.1 1.9 21 12.2 15.9 1.8 20.2 11.5 106 6 102 165 7.8 0 8 7.8 06/08/2006 23:50:00 16.7 1.7 20.6 11.8 17 1.7 21 11.1 15.5 1.8 19.9 10.7 106 6 102 165 7.8 0 8.3 7.8 06/09/2006 00:00:00 16.2 2.2 21 9.5 16.5 2.2 21.8 9.9 15.3 2.4 21 9.5 109 7 99 165 7.8 0 8.3 7.8 06/09/2006 00:10:00 16.9 1.7 21.4 11.8 17.2 1.7 21.8 12.2 15.9 1.9 21.8 11.5 107 6 114 165 7.9 0 8 7.8 06/09/2006 00:20:00 16.5 1.7 20.2 11.1 16.8 1.8 21.4 11.1 15.5 2.1 20.2 9.9 107 6 111 165 7.9 0 8 7.8 06/09/2006 00:30:00 15.8 2 21 10.3 16.1 2 21.4 11.1 14.8 2.1 20.6 10.3 108 6 107 165 8 0 8 7.8 06/09/2006 00:40:00 15.9 1.5 19.9 11.8 16.3 1.5 20.2 11.8 15.1 1.7 19.1 10.3 106 6 112 165 8 0 8 7.8 06/09/2006 00:50:00 15.7 1.8 19.5 9.1 16 1.9 19.5 9.9 14.9 1.9 19.1 9.5 106 7 107 165 8 0 8.5 7.8 06/09/2006 01:00:00 15.8 1.7 19.9 9.5 16.1 1.7 20.2 9.5 14.9 1.9 18.7 8.4 106 7 110 165 8 0 8.5 7.8 06/09/2006 01:10:00 15.7 1.6 20.6 11.8 16.1 1.7 21.4 11.1 14.9 1.8 19.5 9.1 105 7 105 165 7.9 0 8 7.8 06/09/2006 01:20:00 15.8 1.4 19.9 12.2 16.2 1.5 20.2 12.2 15 1.6 19.1 10.7 106 6 103 165 7.9 0 8 7.8 06/09/2006 01:30:00 16.1 1.7 20.6 12.2 16.4 1.7 20.6 12.6 15.1 1.8 19.1 10.3 105 7 103 165 7.9 0 8 7.8 06/09/2006 01:40:00 16.5 1.6 19.5 10.7 16.8 1.6 20.2 11.1 15.6 1.9 19.9 10.3 105 6 111 165 8 0 8 7.8 06/09/2006 01:50:00 15.7 1.4 20.2 11.8 16.1 1.5 20.6 12.6 14.9 1.6 19.1 10.7 107 6 113 165 8 0 8 7.8 06/09/2006 02:00:00 15.2 1.9 20.2 9.9 15.4 2 20.2 9.9 14.3 2.2 19.9 8 107 6 113 165 7.9 0.1 8.5 7.3 06/09/2006 02:10:00 15.5 1.5 19.5 11.8 15.8 1.5 19.9 11.8 14.8 1.5 18.3 9.5 108 6 110 165 7.9 0.1 8 7.3 06/09/2006 02:20:00 14.8 1.4 18.7 11.1 15.1 1.4 19.5 11.1 14.1 1.5 17.9 9.9 109 7 111 165 8 0.1 8 7.3 06/09/2006 02:30:00 15.1 1.3 17.9 10.3 15.4 1.3 18.3 10.3 14.1 1.5 18.7 9.9 109 5 116 165 8 0.1 8 7.3 06/09/2006 02:40:00 14.4 1.5 18.7 10.7 14.7 1.5 19.1 10.7 13.7 1.7 17.9 10.3 108 6 107 165 8 0.1 8 7.3 06/09/2006 02:50:00 14.7 1.3 18.3 11.1 15 1.4 18.3 11.1 13.8 1.7 19.1 9.1 107 5 111 165 8 0.1 8 7.3 06/09/2006 03:00:00 14.3 1.3 17.2 10.3 14.6 1.3 17.9 10.7 13.4 1.3 16.1 9.5 106 7 95 165 8 0.1 8 7.3 06/09/2006 03:10:00 14.6 1.2 17.6 11.1 14.9 1.3 17.9 11.5 13.8 1.4 16.4 9.5 106 6 105 165 7.9 0.1 8 7.3 06/09/2006 03:20:00 14 1.1 17.2 10.7 14.3 1.1 17.2 11.1 13.3 1.2 16.1 9.5 108 6 99 165 7.9 0.1 8 7.3 06/09/2006 03:30:00 13.9 1.5 17.6 8.4 14.1 1.5 17.6 8.4 13.1 1.5 17.2 8.8 109 6 114 165 8 0.1 8 7.3 06/09/2006 03:40:00 13.7 1.1 17.2 9.9 14 1.1 17.6 10.3 13.1 1.2 17.2 9.5 110 6 118 165 8 0.1 8 7.3 06/09/2006 03:50:00 13.3 1.3 16.4 8.8 13.6 1.3 16.8 8.8 12.5 1.4 16.1 8.4 110 6 116 165 8 0.1 8 7.3 06/09/2006 04:00:00 12.9 1.2 16.1 10.3 13.2 1.2 16.8 10.3 12.2 1.2 15.3 9.5 110 7 112 165 8 0.1 8 7.3 06/09/2006 04:10:00 12.4 1.3 15.6 8.4 12.7 1.3 16.1 8.8 11.9 1.6 15.6 7.6 113 6 112 165 8 0.1 8 7.3 06/09/2006 04:20:00 12.7 1.5 16.1 8 13 1.5 16.4 8.4 12.1 1.5 16.4 7.6 109 7 114 165 8 0 8 7.8 06/09/2006 04:30:00 12.1 1.4 15.3 7.6 12.4 1.5 15.6 7.6 11.4 1.5 14.9 7.2 111 6 107 165 8 0 8 7.8 06/09/2006 04:40:00 11.7 1.3 14.5 7.6 12 1.3 14.9 8 11.1 1.3 14.5 7.6 110 7 119 165 8 0 8 7.8 06/09/2006 04:50:00 11.9 1.3 15.6 7.6 12.2 1.3 16.1 8.4 11.2 1.4 14.9 8 111 6 112 165 8 0 8 7.8 06/09/2006 05:00:00 11.9 1.2 15.3 9.1 12.2 1.2 15.6 9.1 11.4 1.3 14.9 7.6 112 8 117 165 8 0 8 8 06/09/2006 05:10:00 11.5 1.1 14.5 7.2 11.8 1.2 15.3 7.6 11 1.3 14.9 8 114 7 102 165 8 0 8.3 8 06/09/2006 05:20:00 11.4 1.2 14.5 8.4 11.7 1.2 14.9 8 10.9 1.3 14.5 7.6 116 6 119 165 8 0 8.3 8 06/09/2006 05:30:00 11.8 1 14.5 8.8 12 1 14.9 9.1 11.2 1 13.7 8 113 6 114 165 8 0 8.3 8 06/09/2006 05:40:00 11.6 1.2 14.1 7.2 11.7 1.2 14.1 8 11 1.3 14.1 6.8 113 7 116 165 8 0 8.3 8 06/09/2006 05:50:00 11.1 1 14.1 7.6 11.3 1 14.5 7.6 10.6 1.2 13.7 7.2 117 6 122 165 8 0 8.3 8 06/09/2006 06:00:00 11 1.2 14.1 7.2 11.1 1.3 14.1 7.6 10.5 1.5 13.3 7.2 116 7 124 165 8 0 8.3 8 06/09/2006 06:10:00 11.1 0.9 13.3 8 11.4 0.9 13.7 8.4 10.7 1.1 14.1 7.6 118 6 110 165 8 0 8.5 8 06/09/2006 06:20:00 10.4 1.1 13.7 6.8 10.6 1.1 14.1 6.8 10 1.1 14.1 6.5 121 6 121 165 8 0 8.3 8 06/09/2006 06:30:00 10.6 1 13 7.6 10.8 1.1 13 7.6 10.4 1.2 13 7.2 121 6 122 165 8 0 8.3 7.5 06/09/2006 06:40:00 10.5 1 13.3 7.6 10.7 1 13.7 7.2 10.1 1.1 13.3 7.6 120 6 124 165 8 0 8.3 7.5 06/09/2006 06:50:00 10.4 1 13 8 10.6 1 13.3 8 9.9 1.1 13 6.8 119 6 111 165 8 0 8.3 7.5 06/09/2006 07:00:00 10.3 1 12.6 7.2 10.4 1 13.3 7.2 9.9 1 13 7.6 122 6 118 165 8 0 8.3 7.5 06/09/2006 07:10:00 10.5 1.1 13.3 7.6 10.6 1.1 13.7 8 10.3 1.1 13.3 7.2 126 8 148 165 8 0 8.3 7.5 06/09/2006 07:20:00 10.6 1.2 13.7 7.6 10.7 1.2 13.7 7.2 10.4 1.3 13.3 6.5 133 9 133 165 8.1 0 8.3 7.5 06/09/2006 07:30:00 11.1 1.3 15.3 7.6 11.1 1.3 15.3 7.2 10.8 1.3 14.1 8 133 8 128 165 8.1 0 8.3 7.8 06/09/2006 07:40:00 11.7 1.1 14.5 8.8 11.9 1.1 14.5 8.8 11.5 1.2 14.1 7.6 132 6 128 165 8.1 0 8.3 7.8 06/09/2006 07:50:00 10.4 1.1 13 8 10.6 1.1 13.3 8.4 10.2 1.1 13 7.2 135 7 135 165 8.1 0 8.3 7.8 06/09/2006 08:00:00 11.4 1.1 14.1 7.6 11.5 1.1 14.1 8.4 11.1 1.1 14.1 8.4 135 7 135 165 8.1 0 8.3 7.8 06/09/2006 08:10:00 10.8 1.1 14.1 7.6 10.8 1.1 14.1 7.6 10.6 1.1 14.5 8.4 140 8 133 165 8.1 0 8.3 7.8 06/09/2006 08:20:00 11 1.4 14.1 6.8 11 1.4 14.1 6.5 10.9 1.4 14.1 6.1 141 8 139 165 8.1 0 8.3 7.8 06/09/2006 08:30:00 11.4 1.3 14.5 8.4 11.5 1.3 14.9 8.4 11.5 1.3 14.5 8.4 141 7 136 165 8.1 0 8.3 7.8 06/09/2006 08:40:00 11.7 1.1 14.5 8.4 11.7 1.2 14.5 8.4 11.4 1.2 14.5 8.4 141 7 140 165 8.1 0 8.3 7.8 06/09/2006 08:50:00 11.7 0.9 13.7 9.5 11.8 0.8 13.7 9.5 11.5 1 13.7 8.4 141 5 143 165 8.2 0 8.5 7.8 06/09/2006 09:00:00 12 0.8 14.1 9.9 12 0.8 14.1 9.9 11.9 0.9 13.7 9.5 145 5 145 165 8.3 0 8.5 8.3 06/09/2006 09:10:00 12.3 0.8 14.1 10.3 12.3 0.8 14.1 10.3 12.1 1 14.5 9.1 145 4 148 165 8.3 0 8.5 8.3 06/09/2006 09:20:00 12.2 0.6 14.1 10.3 12.2 0.6 14.1 10.7 12.3 0.6 13.7 9.9 145 3 144 165 8.3 0 8.8 8.3 06/09/2006 09:30:00 12.3 0.6 13.7 10.3 12.3 0.6 13.7 10.7 12.2 0.7 13.7 10.3 145 4 150 165 8.5 0 8.5 8.3 06/09/2006 09:40:00 12.8 1 14.9 9.9 12.9 1 14.9 10.3 12.8 1 14.9 9.9 145 4 144 165 8.4 0 8.8 8.3 06/09/2006 09:50:00 13.2 0.7 14.9 11.5 13.3 0.6 14.9 11.8 13.1 0.7 14.5 11.1 145 3 144 165 8.4 0 8.5 8.3 06/09/2006 10:00:00 13.4 0.6 14.9 11.5 13.4 0.6 14.9 11.8 13.4 0.8 15.3 10.7 146 3 148 165 8.2 0 8.5 8 06/09/2006 10:10:00 12.9 0.5 13.7 11.1 12.9 0.5 14.1 11.1 12.9 0.6 14.1 10.3 145 3 139 165 8.3 0 8.5 8.3 06/09/2006 10:20:00 12.2 0.7 13.7 9.1 12.3 0.7 13.7 9.5 12.1 0.7 14.1 10.3 146 4 147 165 8.4 0 8.5 8.3 06/09/2006 10:30:00 12.4 0.8 14.9 9.5 12.5 0.8 14.9 9.5 12.4 0.9 14.9 9.5 146 4 147 165 8.2 0 8.8 8 06/09/2006 10:40:00 12.8 0.6 14.1 11.1 12.8 0.6 14.5 11.1 12.8 0.7 14.1 10.7 148 3 150 165 8.2 0 8.5 8 06/09/2006 10:50:00 13.6 0.8 15.6 11.1 13.6 0.8 15.3 11.5 13.6 0.9 15.3 10.3 147 3 151 165 8.1 0 8.3 8 06/09/2006 11:00:00 13.4 0.8 15.3 10.7 13.3 0.8 14.9 11.1 13.2 1 15.3 9.9 147 4 144 165 8 0 8.5 7.8 06/09/2006 11:10:00 12.2 0.7 14.1 10.3 12.3 0.7 14.1 10.7 12.1 0.8 13.7 9.9 147 4 147 165 8 0.1 8.3 7.5 06/09/2006 11:20:00 12.9 0.8 14.5 10.3 12.9 0.7 14.5 10.3 12.8 1 14.9 9.5 148 3 145 165 7.7 0 8 7.3 06/09/2006 11:30:00 11.9 0.8 14.1 10.3 11.9 0.8 14.1 10.3 11.8 0.8 13.7 9.9 149 3 153 165 7.6 0 7.8 7.3 06/09/2006 11:40:00 11.1 0.6 13 9.5 11.2 0.6 12.6 9.5 11.1 0.8 13 8.8 147 4 152 165 7.6 0 7.8 7.3 06/09/2006 11:50:00 11.4 0.6 13 9.1 11.4 0.6 13 9.5 11.3 0.7 13 9.1 148 3 145 165 7.6 0 7.8 7.3 06/09/2006 12:00:00 10.9 0.6 12.2 8.8 10.9 0.6 12.2 8.8 10.8 0.7 13 8.8 148 4 144 165 7.6 0 7.8 7.3 06/09/2006 12:10:00 11.4 0.7 13 9.5 11.4 0.7 13 9.5 11.3 0.8 13 9.1 147 5 143 165 7.6 0 7.8 7.3 06/09/2006 12:20:00 11.7 0.7 13.7 9.9 11.7 0.7 13.3 9.9 11.7 0.7 13.3 9.9 148 4 153 165 7.4 0 7.8 7 06/09/2006 12:30:00 11.5 0.9 13.3 9.1 11.5 0.9 13.3 9.1 11.2 1.1 13.7 7.6 148 4 146 165 7.6 0 7.8 7.3 06/09/2006 12:40:00 12.1 0.8 13.7 9.9 12.1 0.8 13.7 9.9 12.1 0.9 14.1 9.1 148 5 150 165 7.6 0 7.8 7.3 06/09/2006 12:50:00 12 0.8 14.5 9.5 12.1 0.8 14.5 9.9 11.8 0.9 13.7 9.1 146 4 147 165 7.7 0 7.8 7.3 06/09/2006 13:00:00 12.2 0.8 13.7 10.3 12.3 0.7 13.7 10.3 12 0.9 14.9 9.9 146 4 145 165 7.7 0 7.8 7.3 06/09/2006 13:10:00 11.9 0.7 13.3 9.5 11.9 0.7 13.3 9.1 11.9 0.8 13.7 9.1 146 4 150 165 7.7 0 7.8 7.3 06/09/2006 13:20:00 12.2 0.7 13.7 10.7 12.2 0.6 13.7 10.7 12.1 0.8 14.1 9.5 147 4 151 165 7.7 0 7.8 7.3 06/09/2006 13:30:00 13 1.1 15.3 9.5 13 1.1 15.3 9.5 12.9 1.2 15.3 9.1 145 4 143 165 7.7 0 7.8 7.5 06/09/2006 13:40:00 14.7 0.9 16.8 13 14.7 0.9 17.2 12.6 14.6 1 17.2 11.1 144 4 146 165 7.7 0 7.8 7.5 06/09/2006 13:50:00 16.1 0.7 17.9 14.1 16.1 0.7 17.9 14.1 16.2 0.8 17.9 14.1 145 3 141 165 7.8 0 8.3 7.5 06/09/2006 14:00:00 15.2 1 17.2 12.6 15.2 1 17.2 12.6 15 1 17.2 11.8 147 4 146 165 7.8 0 8 7.8 06/09/2006 14:10:00 15.5 1 17.6 12.6 15.6 1 17.6 12.2 15.4 1.3 17.9 11.5 147 3 148 165 8 0 8.3 7.8 06/09/2006 14:20:00 16.7 0.7 18.3 13.7 16.7 0.7 18.7 14.5 16.6 0.9 19.1 14.1 148 3 153 165 8.1 0 8.3 8 06/09/2006 14:30:00 15.8 0.9 17.9 13 15.7 1 17.9 13 15.8 1.1 18.7 11.8 151 3 148 165 8.5 0.2 9 8 06/09/2006 14:40:00 14.5 0.8 17.2 11.8 14.4 0.8 17.6 11.8 14.3 1 17.6 11.1 151 4 151 165 8.5 0.1 9 8.3 06/09/2006 14:50:00 15.3 0.8 17.9 13 15.3 0.8 17.9 13 15.2 1 18.3 12.2 151 3 153 165 8.3 0 8.5 8 06/09/2006 15:00:00 13.7 0.9 16.4 10.7 13.7 0.9 16.1 10.3 13.8 1 16.8 10.7 153 5 149 165 8 0 8.3 7.8 06/09/2006 15:10:00 12.7 1.1 15.6 9.5 12.7 1.1 15.6 9.9 12.7 1.2 15.6 8.4 151 4 159 165 7.8 0 8.5 7.8 06/09/2006 15:20:00 11.6 0.7 13.3 9.1 11.5 0.7 13.3 9.1 11.7 0.8 13.3 8.8 153 4 150 165 7.8 0 8 7.8 06/09/2006 15:30:00 11.8 1 13.7 8.8 11.6 1 13.3 9.1 11.9 1 14.1 8.8 156 5 158 165 7.7 0 7.8 7.5 06/09/2006 15:40:00 11.5 0.6 13.3 9.9 11.4 0.6 13.7 9.9 11.7 0.7 13.3 10.3 155 4 157 165 7.7 0 8.3 7.3 06/09/2006 15:50:00 10.8 0.6 12.2 9.1 10.8 0.6 12.2 9.1 11 0.7 12.6 9.1 153 3 152 165 7.7 0 7.8 7.3 06/09/2006 16:00:00 10.7 0.7 12.6 9.1 10.7 0.7 12.6 9.1 10.8 0.8 12.6 9.1 150 3 153 165 7.7 0 8 7.5 06/09/2006 16:10:00 10.8 0.6 12.2 8.8 10.8 0.6 12.6 9.1 10.8 0.8 12.2 9.1 149 3 147 165 7.7 0 7.8 7.5 06/09/2006 16:20:00 10.7 0.6 11.8 9.1 10.7 0.6 11.8 8.8 10.6 0.7 12.2 8 148 4 140 165 7.6 0 7.8 7.3 06/09/2006 16:30:00 11.2 0.8 13.3 8.8 11.2 0.9 13.3 9.1 11.1 1 13.7 8 148 3 148 165 7.6 0 7.8 7.3 06/09/2006 16:40:00 10.8 0.7 12.6 8.4 10.9 0.7 12.6 8.4 10.6 0.8 13 8 145 4 145 165 7.5 0 7.8 7 06/09/2006 16:50:00 10.1 0.6 11.5 8.8 10.1 0.6 11.5 8.4 10.1 0.6 11.5 8.4 148 3 145 165 7.6 0 7.8 7.3 06/09/2006 17:00:00 9.8 0.6 11.1 8 9.8 0.6 11.1 8 9.8 0.7 11.8 7.6 149 4 145 165 7.6 0 7.8 7.3 06/09/2006 17:10:00 10.1 0.7 12.2 8.4 10.2 0.7 11.8 8 10.1 0.8 11.8 8 148 4 145 165 7.5 0 7.8 7 06/09/2006 17:20:00 10.3 0.7 12.2 8.4 10.3 0.6 12.2 8.8 10.2 0.8 12.2 8 150 4 145 165 7.4 0.1 7.8 7 06/09/2006 17:30:00 10.4 1.2 12.6 8 10.4 1.2 12.6 7.6 10.2 1.2 13 7.2 147 5 146 165 7.4 0.1 7.5 6.7 06/09/2006 17:40:00 10.8 0.8 12.2 7.6 10.8 0.8 12.6 8.4 10.6 1 12.6 7.2 148 5 156 165 7.4 0.1 7.5 6.7 06/09/2006 17:50:00 11.3 0.8 13.3 8.4 11.3 0.8 13.3 8.4 11.1 1 13 7.6 148 3 145 165 7.4 0.1 7.5 6.7 06/09/2006 18:00:00 11.5 0.7 13.3 9.1 11.5 0.7 13.3 9.1 11.2 0.8 13 8.8 146 5 144 165 7.4 0 7.8 7.3 06/09/2006 18:10:00 12 1 14.1 9.5 12.1 1 14.1 9.1 12 1 14.5 9.5 148 4 149 165 7.4 0 7.5 7.3 06/09/2006 18:20:00 12.3 1 14.5 9.9 12.4 1 14.5 9.1 12.1 1.2 14.5 8.8 148 3 150 165 7.4 0 7.5 7.3 06/09/2006 18:30:00 11.3 0.6 12.6 9.1 11.4 0.6 12.6 9.5 11.1 0.8 12.6 8.8 150 3 153 165 7.4 0 7.5 7.3 06/09/2006 18:40:00 11 0.6 12.6 8.8 11 0.6 12.6 8.8 11 0.8 13 8.4 149 3 147 165 7.4 0 7.5 7.5 06/09/2006 18:50:00 10.9 0.7 12.6 8.8 11 0.7 13 8.8 10.8 0.8 12.2 8.4 149 3 150 165 7.5 0 7.8 7.5 06/09/2006 19:00:00 11.8 0.5 13.3 10.3 11.9 0.5 13.3 10.7 11.7 0.6 13.7 9.5 149 4 148 165 7.4 0.1 8 7.5 06/09/2006 19:10:00 11.8 0.8 13.7 9.9 11.9 0.8 13.7 9.9 11.6 1 14.5 8.8 146 4 145 165 7.6 0 7.8 7.5 06/09/2006 19:20:00 12.8 0.8 14.9 10.3 12.9 0.7 14.9 10.7 12.7 0.8 14.5 10.3 148 3 147 165 7.6 0 7.8 7.5 06/09/2006 19:30:00 13 0.8 14.5 10.7 13 0.8 14.5 10.3 12.9 1 14.9 10.3 149 3 152 165 7.5 0 7.5 7.5 06/09/2006 19:40:00 11.8 0.6 13.3 9.5 11.9 0.6 13.3 9.1 11.5 0.8 13 9.1 148 4 151 165 7.5 0 7.8 7.5 06/09/2006 19:50:00 12.7 0.7 14.5 10.7 12.7 0.7 14.5 10.7 12.4 0.9 14.1 9.5 148 4 147 165 7.5 0 7.8 7.5 06/09/2006 20:00:00 12.2 0.7 13.7 9.9 12.2 0.6 13.3 10.3 12 0.9 13.7 9.1 149 3 148 165 7.5 0 8 7.5 06/09/2006 20:10:00 12 0.6 13.3 9.9 12.1 0.6 13.3 10.3 11.8 0.6 13.7 9.5 149 3 146 165 7.5 0 7.8 7.5 06/09/2006 20:20:00 12 0.8 13.7 9.9 12.1 0.7 14.1 9.9 11.8 0.9 13.7 8.8 149 5 149 165 7.5 0 7.8 7.5 06/09/2006 20:30:00 11.9 0.6 13.3 10.3 12 0.7 13.7 10.3 11.9 0.8 13.7 9.1 150 4 154 165 7.4 0 7.5 7 06/09/2006 20:40:00 11.4 0.6 12.6 9.9 11.5 0.6 13 9.9 11.4 0.7 13.3 9.5 150 3 150 165 7.5 0 7.8 7.5 06/09/2006 20:50:00 11.5 0.5 12.6 9.9 11.6 0.5 13 10.3 11.4 0.6 13 8.8 151 3 147 165 7.4 0 7.5 7.3 06/09/2006 21:00:00 10.9 0.5 12.6 9.1 11 0.5 12.6 9.1 10.9 0.6 12.6 8.8 151 3 149 165 7.4 0 7.8 7.3 06/09/2006 21:10:00 10.4 0.7 12.2 8.4 10.5 0.7 12.2 8.4 10.4 0.8 12.6 8.4 151 3 154 165 7.4 0 7.5 7 06/09/2006 21:20:00 10.9 0.6 12.6 8.8 11 0.6 13 9.1 10.9 0.8 12.6 8 152 3 155 165 7.2 0 7.5 7 06/09/2006 21:30:00 10.9 0.6 12.6 9.5 10.9 0.6 12.6 9.5 11.1 0.7 13 9.1 153 4 153 165 7.1 0 7.3 7 06/09/2006 21:40:00 11.2 0.6 12.6 9.5 11.1 0.6 12.6 9.9 11.3 0.7 12.6 9.1 153 3 150 165 7.1 0 7.3 7 06/09/2006 21:50:00 10.5 0.4 11.5 8.8 10.5 0.4 11.5 8.8 10.6 0.6 11.5 7.6 151 3 151 165 7 0 7.3 7 06/09/2006 22:00:00 9.8 0.6 11.5 8 9.9 0.5 11.5 8.4 9.9 0.7 11.8 8 151 3 154 165 7.1 0 7.3 7 06/09/2006 22:10:00 9.4 0.6 11.1 8 9.5 0.6 11.5 8 9.4 0.7 11.8 8 148 3 148 165 7.2 0 7.3 7.3 06/09/2006 22:20:00 9.8 0.7 11.5 8 9.8 0.6 11.8 8 9.8 0.7 11.8 8 150 4 148 165 7.2 0 7.3 7.3 06/09/2006 22:30:00 10.1 0.5 11.8 8.8 10.1 0.5 11.5 8.8 10.3 0.6 12.2 8 152 3 151 165 7.1 0 7.3 7 06/09/2006 22:40:00 10.4 0.6 12.2 8.4 10.4 0.6 11.8 8.8 10.5 0.6 12.2 8.4 151 4 148 165 7 0 7.3 7 06/09/2006 22:50:00 9.9 0.8 11.8 8 9.9 0.8 11.8 8 10 0.8 12.2 7.6 154 4 158 165 6.9 0 7.3 7 06/09/2006 23:00:00 9.5 0.7 11.1 8 9.4 0.7 11.1 8 9.4 0.7 11.1 8 152 5 147 165 7.1 0 7.3 7 06/09/2006 23:10:00 10.2 0.7 11.8 8.4 10.2 0.7 11.8 8.4 10.1 0.9 12.2 8 150 4 153 165 7.3 0 7.5 7.3 06/09/2006 23:20:00 12.4 0.7 14.5 10.7 12.4 0.7 14.5 10.7 12.3 0.9 14.5 9.5 149 3 145 165 7.4 0 7.5 7.3 06/09/2006 23:30:00 13.4 0.7 15.3 10.7 13.5 0.8 15.3 11.1 13.3 0.9 14.9 10.7 149 4 146 165 7.4 0 7.5 7.3 06/09/2006 23:40:00 13 0.9 15.3 10.7 13.1 0.9 15.3 10.7 12.8 1 15.3 9.9 149 5 151 165 7.4 0 7.5 7.3 06/09/2006 23:50:00 13.7 0.8 15.3 11.1 13.7 0.8 15.3 11.1 13.7 0.9 15.3 10.7 151 3 148 165 7.4 0 7.5 7.3 06/10/2006 00:00:00 12.7 0.8 14.5 10.7 12.7 0.7 14.5 10.7 12.6 0.9 14.5 9.1 151 3 152 165 7.3 0 7.8 7.3 06/10/2006 00:10:00 12.8 0.7 14.5 10.7 12.8 0.7 14.5 11.1 12.6 1 14.9 9.5 151 3 146 165 7.3 0 7.5 7.3 06/10/2006 00:20:00 13 0.8 14.5 11.1 13.1 0.8 14.9 10.7 13 0.8 14.5 10.3 151 3 148 165 7.4 0 7.5 7.3 06/10/2006 00:30:00 12.4 0.9 14.5 9.5 12.5 0.8 14.1 9.5 12.3 1.1 14.5 8 151 3 150 165 7.4 0 7.5 7.3 06/10/2006 00:40:00 12.9 0.9 15.3 9.9 13 0.9 15.3 9.9 12.6 1.2 15.6 9.1 150 4 153 165 7.3 0 7.5 7.3 06/10/2006 00:50:00 12.2 0.6 13.7 10.7 12.2 0.6 13.7 10.7 12.1 0.7 14.1 9.9 152 3 149 165 7.3 0 7.5 7.3 06/10/2006 01:00:00 11.9 0.6 13.3 10.3 11.9 0.6 13.3 10.3 12 0.8 13.7 8.8 154 5 156 165 7.3 0 7.8 7.3 06/10/2006 01:10:00 12.6 0.8 14.5 10.3 12.5 0.8 14.5 9.9 12.7 0.8 14.9 9.9 153 6 148 165 7.1 0 7.3 7.3 06/10/2006 01:20:00 11.9 0.6 14.5 10.3 11.8 0.6 14.5 9.9 12 0.7 14.9 9.5 154 4 149 165 7.2 0 7.5 7 06/10/2006 01:30:00 12.5 0.6 14.5 10.7 12.4 0.6 14.5 10.7 12.5 0.6 14.1 10.3 154 3 157 165 7.2 0 7.3 7 06/10/2006 01:40:00 11.4 0.6 13.3 9.5 11.4 0.6 13.3 9.9 11.4 0.7 13 9.1 153 4 157 165 7.1 0 7.3 7 06/10/2006 01:50:00 10.9 0.7 13.3 9.1 10.9 0.7 13 8.8 10.9 0.7 12.2 8.8 150 4 157 165 7.1 0 7.3 7 06/10/2006 02:00:00 11.2 0.8 13.3 9.1 11.2 0.8 13.7 9.1 11.1 0.9 14.1 9.1 149 3 154 165 7.1 0 7.5 7 06/10/2006 02:10:00 11.1 0.5 12.6 9.5 11.1 0.5 12.6 9.5 11 0.6 12.6 9.1 150 3 148 165 7.1 0 7.3 7 06/10/2006 02:20:00 12.3 1 14.5 9.9 12.3 1 14.5 9.9 12.1 1 14.9 9.5 150 3 148 165 7.1 0 7.3 7 06/10/2006 02:30:00 12.5 1 15.3 10.7 12.5 1 15.3 10.3 12.4 1.1 16.1 10.3 152 3 153 165 7.1 0 7.3 7 06/10/2006 02:40:00 12.2 0.7 13.7 10.3 12.2 0.7 14.1 10.7 12.1 0.9 14.1 9.5 151 4 147 165 7.1 0 7.3 7 06/10/2006 02:50:00 12.1 0.7 13.7 9.9 12.2 0.7 13.7 10.3 12 0.8 13.7 9.5 150 3 151 165 7.1 0 7.3 7 06/10/2006 03:00:00 12.5 0.8 14.5 10.3 12.5 0.7 14.1 10.3 12.5 0.9 14.1 10.3 152 4 151 165 6.9 0 7.5 7 06/10/2006 03:10:00 12.7 0.7 14.5 10.7 12.7 0.7 14.5 10.7 12.6 1 15.6 9.9 152 4 153 165 6.9 0 7 7 06/10/2006 03:20:00 12.7 0.7 14.9 11.1 12.7 0.8 15.3 10.7 12.6 0.9 16.1 10.3 151 4 152 165 6.9 0 7 6.7 06/10/2006 03:30:00 13.1 0.8 15.3 10.7 13 0.8 15.6 10.7 13.2 1 15.6 10.7 154 5 150 165 6.9 0 7 7 06/10/2006 03:40:00 12.7 0.7 14.5 10.7 12.6 0.7 14.5 10.3 12.7 0.8 14.9 10.3 153 4 153 165 6.9 0 7 7 06/10/2006 03:50:00 12.2 0.7 13.7 9.9 12.2 0.7 13.7 10.3 11.9 0.8 13.7 9.1 150 3 151 165 6.9 0 7 6.7 06/10/2006 04:00:00 12.6 0.8 14.1 10.7 12.6 0.8 14.5 10.3 12.7 0.9 14.5 9.5 153 3 157 165 6.9 0 7 6.7 06/10/2006 04:10:00 13 1.3 16.4 7.6 12.8 1.2 15.6 7.2 13.1 1.3 16.4 8.8 167 12 166 165 6.6 0.2 7 6 06/10/2006 04:20:00 11.7 1.2 14.5 8.8 11.4 1.1 14.1 8.8 11.8 1.2 14.5 9.1 176 5 165 165 6.1 0 6.2 6 06/10/2006 04:30:00 10.6 0.8 13 8.8 10.3 0.8 12.6 8.4 10.7 0.8 13 8.8 169 8 180 165 6.1 0 6.2 6 06/10/2006 04:40:00 9 0.8 10.7 6.8 8.9 0.7 10.7 7.2 9 0.8 10.3 6.5 165 12 160 165 6.2 0 6.2 6 06/10/2006 04:50:00 8.4 0.7 10.3 6.8 8.3 0.6 10.3 6.8 8.6 0.7 10.3 6.8 160 4 160 165 6.2 0 6.2 6.2 06/10/2006 05:00:00 8.2 0.6 10.3 6.8 8.2 0.6 10.3 6.5 8.3 0.6 9.9 6.1 156 5 154 165 6.3 0 6.2 6.2 06/10/2006 05:10:00 10.4 0.8 12.6 8 10.4 0.8 12.6 8.4 10.3 0.9 13 8 150 5 154 165 6.4 0 6.5 6.2 06/10/2006 05:20:00 9.5 0.8 11.8 7.2 9.4 0.8 11.5 7.2 9.8 0.9 11.8 7.6 166 8 172 165 6.4 0 6.7 6.2 06/10/2006 05:30:00 11.1 1 13 8.4 10.8 0.9 12.6 8.4 11.2 1 13.3 9.1 175 5 165 165 6.3 0 6.7 6 06/10/2006 05:40:00 10.9 0.6 12.2 9.5 10.5 0.6 11.8 9.1 11 0.6 12.6 9.1 167 4 166 165 6.2 0 6.2 6 06/10/2006 05:50:00 10.1 0.6 11.8 8.4 9.9 0.6 11.5 8.4 10.2 0.7 11.8 8.4 166 13 162 165 6.2 0 6.2 6 06/10/2006 06:00:00 10.2 0.5 11.5 8.8 9.9 0.5 11.1 8.4 10.1 0.6 11.8 8.4 165 13 170 165 6.2 0 6.2 6.2 06/10/2006 06:10:00 9.9 0.6 11.5 8.4 9.8 0.6 11.1 8 10.1 0.7 11.8 8 164 5 165 165 6.3 0 6.5 6 06/10/2006 06:20:00 11.4 1.4 14.5 8.8 11.2 1.3 14.1 8.8 11.5 1.4 14.9 8.4 166 7 174 165 6.3 0 6.5 6.2 06/10/2006 06:30:00 13.6 1 16.1 11.1 13.2 0.9 15.3 11.1 13.8 1 16.4 11.1 170 4 167 165 5.9 0.1 6.2 5.7 06/10/2006 06:40:00 14.2 1 16.4 11.5 13.8 0.9 16.1 11.5 14.2 1.2 16.8 10.3 170 8 172 165 5.8 0 6 5.7 06/10/2006 06:50:00 12.9 0.8 14.5 10.7 12.6 0.7 14.1 10.3 13.1 0.8 15.3 10.3 166 17 160 165 5.9 0 6 5.7 06/10/2006 07:00:00 10.1 1.5 13 7.2 9.9 1.4 13 7.6 10.2 1.4 13.7 7.6 160 11 165 165 6.1 0 6.2 5.7 06/10/2006 07:10:00 9.1 0.7 10.7 7.6 9 0.7 10.7 7.6 9.4 0.6 11.1 7.6 157 4 163 165 6.2 0 6.2 6 06/10/2006 07:20:00 11.2 1.5 14.9 8.8 11.1 1.5 14.5 8.8 11.2 1.7 15.6 8.4 157 9 174 165 6.3 0 6.2 6 06/10/2006 07:30:00 13.9 0.9 16.1 11.5 13.5 0.8 15.6 11.1 14 1 16.1 11.1 172 6 164 165 5.7 0 6 5.5 06/10/2006 07:40:00 12.1 1.2 14.5 9.9 11.8 1.1 14.1 9.5 12.4 1.3 15.6 9.1 170 11 172 165 5.9 0.2 6.2 5.7 06/10/2006 07:50:00 11.7 1.2 14.9 9.1 11.5 1.1 14.1 9.1 11.9 1.1 14.9 9.5 169 5 166 165 6.2 0 6.2 6 06/10/2006 08:00:00 12.8 0.7 14.9 11.1 12.6 0.6 14.5 11.1 13.2 0.7 15.3 11.1 167 16 170 165 6.2 0 6.5 6 06/10/2006 08:10:00 13.8 0.6 14.9 11.5 13.5 0.6 14.9 11.5 14 0.8 15.6 10.7 166 12 165 165 6.4 0 6.7 6.2 06/10/2006 08:20:00 14.2 0.9 16.4 11.5 14 0.9 16.1 11.1 14.3 1 16.8 11.5 163 13 165 165 6.7 0.1 7 6.5 06/10/2006 08:30:00 15.2 0.8 17.9 13 15 0.8 17.9 12.6 15.5 0.9 17.9 12.6 165 7 165 165 6.9 0 7.3 6.7 06/10/2006 08:40:00 15.4 1.1 18.3 11.8 15.2 1 17.9 12.2 15.6 1.2 19.1 11.1 167 17 162 165 7.4 0.1 7.8 7 06/10/2006 08:50:00 14.4 0.8 16.8 11.8 14.2 0.8 16.1 11.8 14.6 0.9 16.4 11.8 167 7 165 165 7.5 0 7.8 7.5 06/10/2006 09:00:00 13.3 1.1 16.4 10.3 13.2 1 16.1 10.3 13.3 1.2 16.1 10.3 166 6 178 165 7.6 0.1 7.8 7.3 06/10/2006 09:10:00 12.8 0.9 14.9 10.3 12.7 0.9 14.5 10.3 12.9 1.1 15.3 9.5 167 12 135 165 7.6 0.2 8 7.3 06/10/2006 09:20:00 12.5 1.2 15.3 9.5 12.4 1.1 14.9 9.5 12.4 1.3 15.3 9.1 166 13 173 165 8.1 0 8.5 7.8 06/10/2006 09:30:00 12.3 1.2 14.9 8.4 12.1 1.1 14.5 8.4 12.4 1.4 16.1 8.4 168 5 170 165 8.1 0.3 8.5 7.5 06/10/2006 09:40:00 13.4 1 15.3 10.3 13.2 0.9 15.3 10.3 13.5 1.2 15.6 9.1 170 7 166 165 7.4 0 8 7.3 06/10/2006 09:50:00 12.7 1 14.5 9.1 12.6 1 14.5 9.5 12.8 1.2 15.3 9.5 168 13 170 165 7.4 0.1 7.5 7 06/10/2006 10:00:00 13.2 1.2 16.4 10.7 13.1 1.1 16.1 10.7 13.4 1.4 17.2 9.5 168 13 179 165 7.8 0.4 8.5 7.3 06/10/2006 10:10:00 13.1 1 15.6 10.7 12.8 0.9 15.3 10.7 13.4 1 15.6 10.3 171 13 173 165 8 0.3 8.5 7 06/10/2006 10:20:00 12.1 0.8 14.1 9.9 12 0.7 13.7 9.9 12.4 0.8 14.1 10.3 164 6 162 165 8.4 0.1 8.8 8 06/10/2006 10:30:00 13.1 0.9 15.3 10.7 13 0.8 14.9 10.7 13.2 1.1 15.6 9.9 167 13 165 165 7.9 0.4 9 7 06/10/2006 10:40:00 13.3 0.9 15.6 10.3 13.1 0.8 15.3 10.7 13.4 1.2 16.1 8.4 165 13 176 165 7.1 0.2 7.8 6.7 06/10/2006 10:50:00 13.6 1.2 16.1 10.7 13.4 1 16.1 10.7 13.7 1.4 16.4 9.5 164 9 162 165 7.4 0.4 8.3 6.7 06/10/2006 11:00:00 13.5 1.1 16.1 10.7 13.4 1.1 16.1 10.7 13.7 1.3 17.2 9.5 166 12 165 165 8.2 0.3 8.5 7.5 06/10/2006 11:10:00 12.8 1 15.3 9.1 12.6 0.9 14.9 9.5 12.9 1.1 15.6 9.1 163 5 163 165 7.5 0.2 8 7 06/10/2006 11:20:00 14.8 1.3 17.9 11.5 14.4 1.3 17.2 11.1 15.1 1.4 18.3 11.5 167 11 171 165 6.9 0.1 7.3 6.2 06/10/2006 11:30:00 13.2 1.3 16.4 9.9 12.8 1.2 15.6 9.5 13.5 1.3 16.4 9.9 168 9 178 165 6.8 0 7 6.2 06/10/2006 11:40:00 10.3 0.8 12.6 8.4 10.1 0.8 12.2 8.4 10.6 0.8 14.1 8.8 166 12 171 165 7 0 7.3 6.7 06/10/2006 11:50:00 10.4 1.3 14.1 6.5 10.2 1.2 14.1 6.8 10.4 1.3 13 7.6 164 10 160 165 7.1 0 7.3 6.7 06/10/2006 12:00:00 11.7 1 13.7 8.8 11.5 1 13.3 8.8 11.9 1.2 14.5 8 164 5 165 165 6.9 0.2 7.3 6 06/10/2006 12:10:00 11.3 1 13.3 8.8 11 1 13 8.8 11.5 1 13.7 8.8 169 10 173 165 6.7 0 7 6.2 06/10/2006 12:20:00 11.9 0.9 14.5 9.9 11.7 0.9 14.1 9.5 12.1 1 14.1 9.1 166 11 162 165 6.9 0 7.3 6.7 06/10/2006 12:30:00 12.2 1.3 16.1 9.1 12 1.2 15.6 9.1 12.4 1.3 15.6 9.1 166 14 167 165 7.3 0 7.5 7 06/10/2006 12:40:00 12.8 1.3 15.6 9.1 12.6 1.2 15.6 8.8 13.1 1.4 16.4 9.5 165 13 165 165 7.4 0 7.5 7.3 06/10/2006 12:50:00 13.9 1 16.1 10.7 13.7 1 15.6 11.1 14.1 1.2 16.1 10.7 166 4 164 165 7.4 0 7.5 7.3 06/10/2006 13:00:00 12.7 1 15.6 9.9 12.5 1 14.9 9.9 12.9 1.1 15.6 9.5 166 5 165 165 7.1 0 7.8 7 06/10/2006 13:10:00 13.3 1.2 16.1 9.9 13.2 1.1 16.1 10.3 13.6 1.3 16.1 9.1 154 6 156 165 6.7 0 7 6.5 06/10/2006 13:20:00 12.9 1.2 16.1 9.9 12.8 1.1 16.1 9.5 12.9 1.4 16.8 9.1 159 10 153 165 6.4 0 6.7 6.2 06/10/2006 13:30:00 13.5 1.2 16.8 10.3 13.2 1.2 16.4 10.3 13.6 1.2 16.8 9.9 175 8 179 165 6.4 0.1 6.7 6.2 06/10/2006 13:40:00 11 1 13.7 8.4 10.7 1 13.7 8.4 11.2 1 14.1 8.4 170 10 187 165 6.5 0 6.7 6.2 06/10/2006 13:50:00 12.4 1.6 16.1 9.1 12.1 1.6 15.3 9.1 12.8 1.7 16.8 9.5 169 6 165 165 6.9 0.1 7.3 6.7 06/10/2006 14:00:00 13.7 1.2 16.4 10.7 13.3 1.1 15.6 10.7 13.9 1.1 16.8 9.9 171 6 179 165 7.1 0 7.3 7 06/10/2006 14:10:00 13.5 1.1 16.4 10.7 13.1 1 15.6 10.7 13.7 1.2 16.8 10.7 171 6 177 165 7.3 0 7.5 7.3 06/10/2006 14:20:00 14.2 1.2 17.2 11.1 13.8 1.1 16.8 10.3 14.3 1.3 17.9 11.5 173 6 166 165 7.6 0 7.8 7.3 06/10/2006 14:30:00 14.8 0.9 16.8 12.2 14.4 0.8 16.1 12.2 15.2 1 17.2 12.2 169 6 180 165 7.7 0 7.8 7.5 06/10/2006 14:40:00 14.1 0.7 15.6 11.5 13.7 0.6 15.3 11.8 14.4 0.8 16.4 11.8 170 11 180 165 7.5 0 7.8 7.3 06/10/2006 14:50:00 13.9 0.7 15.6 11.8 13.6 0.6 14.9 11.8 14.3 0.7 16.4 12.2 168 7 167 165 7.4 0 7.5 7.3 06/10/2006 15:00:00 13.3 0.6 14.5 11.1 13 0.5 14.1 11.1 13.7 0.5 14.9 12.2 165 17 187 165 7.3 0 7.5 7.3 06/10/2006 15:10:00 13.1 0.8 14.9 10.7 12.8 0.8 14.5 10.3 13.4 1 15.3 10.7 162 9 160 165 7.1 0 7.5 7 06/10/2006 15:20:00 13.8 0.9 16.1 11.1 13.6 0.8 16.1 11.1 13.9 1 16.4 11.1 160 16 162 165 7.1 0 7.3 7 06/10/2006 15:30:00 12.9 0.9 14.9 9.9 12.7 0.8 14.5 9.9 13.1 0.9 14.9 10.3 160 6 162 165 7.1 0 7.3 7 06/10/2006 15:40:00 11.5 0.7 13.3 9.9 11.4 0.7 13 9.5 11.7 0.8 13.7 8.4 161 9 164 165 7.1 0 7.3 7 06/10/2006 15:50:00 11.9 1 14.1 8.8 11.8 1 13.7 8.8 11.8 1.2 14.9 8.4 159 5 163 165 7.4 0 7.5 7.3 06/10/2006 16:00:00 12.3 0.9 15.3 9.5 12.2 0.9 15.3 9.1 12.6 1 14.5 9.5 156 12 158 165 7.4 0 7.5 7.3 06/10/2006 16:10:00 13 1 15.3 9.9 12.9 1 14.9 10.3 13.3 1 15.6 10.7 156 7 159 165 7.3 0 7.5 7.3 06/10/2006 16:20:00 13.5 0.7 15.3 11.1 13.3 0.7 14.9 11.5 13.8 0.8 16.4 11.5 156 4 157 165 7.2 0 7.5 7.3 06/10/2006 16:30:00 11.8 1.1 14.1 8.8 11.7 1 13.7 9.1 11.9 1.1 14.5 9.1 158 5 161 165 7.1 0 7.3 7 06/10/2006 16:40:00 12.1 0.8 14.5 9.9 12 0.8 14.1 9.9 12.3 1 14.9 9.9 159 5 168 165 7.1 0 7.3 7 06/10/2006 16:50:00 12.3 0.8 14.5 9.9 12.2 0.7 14.1 9.9 12.5 0.8 14.5 9.9 158 10 165 165 7.1 0 7.3 7 06/10/2006 17:00:00 13.1 0.8 14.9 10.3 13 0.7 14.5 9.9 13.3 0.8 14.9 11.1 156 3 152 165 7.1 0 7.3 7 06/10/2006 17:10:00 13.8 0.7 15.6 11.8 13.6 0.7 15.3 11.5 14.1 0.8 16.1 12.2 156 3 158 165 7.1 0 7.3 7 06/10/2006 17:20:00 13.5 0.8 15.6 11.1 13.4 0.8 15.3 11.1 13.8 0.8 15.6 11.1 154 3 153 165 7.1 0 7.3 7 06/10/2006 17:30:00 13.7 0.8 15.3 11.5 13.5 0.8 14.9 11.8 13.9 0.8 15.6 11.5 155 3 158 165 7.1 0 7.3 7 06/10/2006 17:40:00 12.3 0.6 13.7 10.7 12.2 0.6 13.7 10.3 12.4 0.7 14.1 9.5 153 3 159 165 7.2 0 7.3 7 06/10/2006 17:50:00 11.6 0.7 13 9.5 11.5 0.7 13 9.5 11.8 0.9 13.3 9.1 152 3 150 165 7.1 0 7.3 7 06/10/2006 18:00:00 10.8 0.7 12.6 8.4 10.8 0.7 12.6 8.8 10.8 0.8 12.6 8.4 151 3 152 165 7 0 7.3 7 06/10/2006 18:10:00 10.3 0.8 12.2 8.4 10.4 0.7 11.8 8.4 10.4 0.9 12.2 7.6 151 4 152 165 7 0 7.3 7 06/10/2006 18:20:00 11.9 0.9 13.7 9.5 11.9 0.8 13.7 9.1 11.9 1.1 14.5 8.8 152 5 156 165 6.9 0 7.3 6.7 06/10/2006 18:30:00 12.1 0.8 14.5 9.9 12.1 0.8 14.1 9.9 11.9 1 14.1 8.8 149 5 152 165 6.8 0 7 6.7 06/10/2006 18:40:00 12.7 0.7 14.5 10.3 12.8 0.7 14.5 10.3 12.7 0.8 14.5 9.1 150 4 150 165 6.7 0 7 6.7 06/10/2006 18:50:00 12.8 0.8 14.9 11.1 12.8 0.8 14.9 11.1 12.7 1 14.9 9.5 145 4 145 165 6.8 0 7 6.7 06/10/2006 19:00:00 13.2 1.2 16.1 10.7 13.3 1.2 16.1 10.3 13.2 1.3 16.1 9.5 146 5 151 165 6.9 0 7 6.7 06/10/2006 19:10:00 13.3 0.8 15.3 11.5 13.4 0.8 15.6 10.7 13.2 1 15.6 10.3 144 4 142 165 6.9 0 7 6.7 06/10/2006 19:20:00 13 1 14.9 10.3 13.1 1 15.3 9.9 12.8 1.1 14.9 8 145 4 146 165 6.9 0 7 6.7 06/10/2006 19:30:00 13.4 0.9 16.4 10.7 13.5 1 16.8 10.7 13.2 1 16.1 10.7 145 5 146 165 6.9 0 7 7 06/10/2006 19:40:00 13.7 1 16.4 10.7 13.8 1 16.8 10.7 13.5 1.1 16.4 10.3 146 5 148 165 6.9 0 7 7 06/10/2006 19:50:00 13.8 1.2 16.8 10.7 13.9 1.2 16.8 10.7 13.7 1.3 17.2 8.8 145 5 142 165 6.9 0 7 7 06/10/2006 20:00:00 14.1 1 16.8 10.7 14.2 1 16.8 11.1 13.9 1.1 17.2 10.7 145 5 139 165 7 0 7.3 7 06/10/2006 20:10:00 14.2 0.9 16.1 11.8 14.2 1 16.4 11.5 13.9 1.1 16.8 10.3 145 6 142 165 7 0 7.3 7 06/10/2006 20:20:00 14.6 1.2 17.2 11.5 14.7 1.3 17.2 11.5 14.5 1.4 17.6 10.7 145 5 141 165 7 0 7.3 7 06/10/2006 20:30:00 15 1 17.2 12.2 15 1.1 17.2 11.8 14.6 1.3 17.2 11.1 144 5 145 165 7 0 7.3 7 06/10/2006 20:40:00 14.8 1 17.2 12.2 14.8 1 17.6 12.6 14.5 1.3 17.6 10.3 146 4 145 165 7.1 0 7.3 7 06/10/2006 20:50:00 14.4 1.2 17.2 11.5 14.4 1.2 17.6 11.8 14.2 1.3 17.2 9.9 146 4 145 165 7.1 0 7.3 7 06/10/2006 21:00:00 14.1 1 16.1 9.9 14.2 1 16.1 10.3 13.9 1.1 16.1 11.1 145 4 147 165 7.1 0 7.5 7 06/10/2006 21:10:00 14.1 0.9 16.1 11.5 14.1 0.9 16.1 11.1 13.9 1 15.6 10.7 146 4 143 165 7.1 0 7.3 7.3 06/10/2006 21:20:00 13.2 0.8 15.3 10.7 13.2 0.8 15.3 10.7 13 1.1 15.3 9.5 147 4 151 165 7.1 0 7.3 7 06/10/2006 21:30:00 12.7 0.8 14.5 10.7 12.7 0.8 14.9 10.7 12.5 1 14.5 9.9 145 3 141 165 7.2 0 7.3 7.3 06/10/2006 21:40:00 13.3 0.6 14.9 11.5 13.4 0.6 14.5 11.5 13.2 0.7 14.9 11.5 145 4 145 165 7.2 0 7.3 7.3 06/10/2006 21:50:00 13.6 0.8 15.3 11.1 13.7 0.8 15.6 11.1 13.3 0.9 15.3 10.3 144 5 139 165 7.3 0 7.3 7.3 06/10/2006 22:00:00 14.6 1 16.8 11.8 14.6 1 16.8 11.8 14.3 1.2 16.8 9.9 146 4 145 165 7.2 0 7.3 7.3 06/10/2006 22:10:00 14.5 0.9 16.4 11.5 14.6 0.9 16.4 11.8 14.4 1.1 16.8 11.1 145 4 145 165 7.2 0 7.3 7.3 06/10/2006 22:20:00 14.1 1.1 16.1 11.1 14.1 1.1 16.1 11.1 13.9 1.3 16.1 9.5 146 4 144 165 7.2 0 7.3 7.3 06/10/2006 22:30:00 14.9 1 17.2 12.6 14.9 1 17.2 12.6 14.6 1.2 17.2 10.7 143 4 141 165 7.2 0 7.3 7.3 06/10/2006 22:40:00 14.6 0.9 16.8 12.2 14.6 0.9 17.2 11.8 14.3 1 16.8 11.5 145 5 143 165 7.2 0 7.3 7 06/10/2006 22:50:00 14.6 0.7 16.4 12.6 14.6 0.7 16.8 12.6 14.3 0.8 16.4 12.2 145 4 149 165 7.3 0 7.3 7.3 06/10/2006 23:00:00 14.5 0.8 16.1 12.2 14.5 0.8 16.1 12.2 14.2 1.1 16.4 11.5 143 4 147 165 7.2 0 7.3 7.3 06/10/2006 23:10:00 14.6 0.8 16.8 12.2 14.6 0.8 16.8 12.2 14.1 1 16.4 11.5 146 4 137 165 7.2 0 7.3 7 06/10/2006 23:20:00 14.2 0.8 16.1 11.8 14.2 0.8 15.6 12.2 14 1 16.1 10.7 148 4 153 165 7 0 7.3 7 06/10/2006 23:30:00 13.6 0.8 16.1 11.1 13.6 0.8 15.6 11.1 13.3 0.9 15.3 10.3 148 4 148 165 7.1 0 7.3 7 06/10/2006 23:40:00 14.3 0.8 16.1 11.8 14.4 0.8 16.1 11.8 14.2 1.1 16.4 10.7 146 4 147 165 7.1 0 7.3 7 06/10/2006 23:50:00 14.7 1 17.2 11.5 14.7 1 17.2 11.5 14.4 1.1 17.2 11.1 144 4 145 165 7.1 0 7.3 7 06/11/2006 00:00:00 14.1 0.9 16.1 11.8 14.1 0.9 16.1 12.2 13.8 1.1 16.8 10.3 145 4 145 165 7.1 0 7.5 7 06/11/2006 00:10:00 13.8 1.1 16.4 11.5 13.8 1.1 16.8 11.5 13.3 1.3 16.4 8.8 145 5 143 165 7.1 0 7.3 7 06/11/2006 00:20:00 14.7 1.1 17.6 11.1 14.8 1.1 17.6 11.8 14.7 1.1 17.2 11.5 145 5 145 165 6.9 0 7.3 7 06/11/2006 00:30:00 13.8 1.1 16.4 10.7 13.9 1.2 16.8 11.1 13.3 1.3 17.2 9.9 143 5 149 165 7 0 7.3 7 06/11/2006 00:40:00 14.3 1 16.4 10.7 14.4 1 16.8 11.1 14 1.1 16.4 10.7 140 6 144 165 6.9 0 7 7 06/11/2006 00:50:00 14.4 1.2 17.2 10.7 14.5 1.2 17.2 11.1 14.1 1.5 17.6 10.3 141 6 130 165 6.9 0 7 6.7 06/11/2006 01:00:00 13.2 1.3 16.4 9.9 13.3 1.3 16.4 10.3 13 1.3 16.8 10.3 143 6 144 165 6.9 0 7 6.7 06/11/2006 01:10:00 13 1.1 16.1 9.5 13.1 1.2 16.1 8.8 12.7 1.3 16.4 8.8 140 6 130 165 6.9 0 7 6.7 06/11/2006 01:20:00 13.3 1.3 16.8 9.1 13.4 1.4 16.8 9.1 12.9 1.6 17.6 8.4 140 7 139 165 6.9 0 7 7 06/11/2006 01:30:00 13.4 1.3 17.2 9.1 13.5 1.3 17.2 9.1 13 1.5 17.2 9.1 133 6 136 165 6.9 0 7 6.7 06/11/2006 01:40:00 14.3 1.3 17.6 9.9 14.5 1.3 17.6 10.3 14.1 1.5 16.8 9.5 136 6 134 165 6.9 0 7 6.7 06/11/2006 01:50:00 13.6 1.3 17.2 10.3 13.7 1.5 17.2 9.9 13.2 1.3 16.4 9.1 137 7 129 165 6.9 0 7 6.7 06/11/2006 02:00:00 13.6 1.6 17.2 9.5 13.7 1.6 17.6 9.9 13.3 1.7 17.9 9.1 137 7 139 165 6.9 0 7 6.7 06/11/2006 02:10:00 13.3 1.3 16.1 9.5 13.4 1.3 16.4 9.9 13 1.5 16.4 8 136 7 134 165 6.9 0 7 6.7 06/11/2006 02:20:00 13.9 1.6 18.3 10.3 14 1.7 18.7 9.9 13.7 1.7 18.7 9.1 131 7 127 165 6.8 0 7 6.7 06/11/2006 02:30:00 13.1 1.5 17.9 8.4 13.2 1.6 17.9 8.4 12.5 1.7 17.6 8.4 132 7 126 165 6.7 0 7 6.7 06/11/2006 02:40:00 13.5 1.2 17.2 10.3 13.6 1.2 17.2 10.3 13 1.3 16.1 9.5 134 7 133 165 6.7 0 7 6.7 06/11/2006 02:50:00 13 1.7 16.8 8 13.1 1.7 17.2 8 12.8 1.9 16.8 7.6 133 8 133 165 6.8 0 7 6.7 06/11/2006 03:00:00 12.8 1.4 16.4 9.5 12.8 1.4 16.4 9.9 12.7 1.5 16.4 9.1 137 7 130 165 6.9 0 7 6.7 06/11/2006 03:10:00 13.3 1.2 16.8 10.3 13.3 1.3 16.8 10.3 13.1 1.2 16.1 9.5 135 7 128 165 6.9 0 7 6.7 06/11/2006 03:20:00 13.4 1.4 16.8 9.1 13.5 1.4 17.2 9.5 12.9 1.4 16.4 9.5 133 7 124 165 6.9 0 7 6.7 06/11/2006 03:30:00 12.4 1.4 15.6 8 12.5 1.5 16.1 7.6 12 1.7 16.8 6.8 134 8 142 165 6.8 0 7 6.7 06/11/2006 03:40:00 13.1 1.3 16.8 9.5 13.3 1.4 17.2 9.9 12.9 1.3 17.2 9.1 129 7 130 165 6.7 0 7 6.7 06/11/2006 03:50:00 12.4 1.7 16.4 8.8 12.5 1.7 16.4 8.8 12.1 1.7 16.8 8 132 7 135 165 6.8 0 7 6.7 06/11/2006 04:00:00 12.9 1.6 16.4 8 13.1 1.5 16.4 8 12.7 1.5 16.8 8.8 129 8 134 165 6.8 0 7.3 6.7 06/11/2006 04:10:00 12.8 1.5 17.6 9.5 12.9 1.6 17.6 9.5 12.4 1.7 17.2 8.4 132 7 116 165 6.8 0 7 6.7 06/11/2006 04:20:00 13.1 1.5 16.4 8.4 13.3 1.5 16.4 8.8 12.8 1.6 16.1 8.8 130 7 130 165 6.8 0 7 6.7 06/11/2006 04:30:00 12.3 1.2 16.1 8.4 12.5 1.3 17.2 8.4 12.1 1.4 16.1 7.6 129 8 119 165 6.8 0 7 6.7 06/11/2006 04:40:00 13 1.5 18.3 9.1 13.3 1.5 19.1 9.1 12.8 1.6 16.8 8.8 130 6 120 165 6.9 0 7 6.7 06/11/2006 04:50:00 13.7 1.2 16.8 10.3 13.8 1.2 17.2 10.3 13.4 1.3 17.6 10.3 133 6 130 165 6.9 0 7 7 06/11/2006 05:00:00 13.3 1.3 16.8 9.5 13.5 1.3 16.8 9.9 13 1.5 17.2 9.5 135 6 135 165 6.9 0 7 7 06/11/2006 05:10:00 13 1.3 16.8 8.8 13.2 1.3 17.2 8.4 12.8 1.3 17.2 8.8 133 7 125 165 6.9 0 7.3 7 06/11/2006 05:20:00 13.1 1.1 16.4 9.5 13.3 1.1 16.8 9.5 12.8 1.2 16.4 9.5 130 6 126 165 6.9 0 7 7 06/11/2006 05:30:00 12.1 1.1 15.3 9.5 12.3 1.1 16.1 9.5 11.6 1.1 14.9 8 130 6 118 165 6.9 0 7.3 7 06/11/2006 05:40:00 12.6 1 15.3 8.8 12.8 1 15.6 8.8 12.4 1 15.6 9.5 131 7 126 165 7 0 7.3 7 06/11/2006 05:50:00 12.3 1 14.9 8.8 12.4 1 15.6 9.1 11.9 1.1 14.1 8.8 130 7 130 165 7.1 0 7.3 7 06/11/2006 06:00:00 13 1.3 16.1 9.9 13.2 1.3 16.4 9.9 12.8 1.4 16.8 9.9 132 8 136 165 7.1 0 7.3 7 06/11/2006 06:10:00 12.9 1.3 16.4 8.4 13 1.3 16.4 9.9 12.5 1.4 16.4 9.1 133 7 138 165 7.1 0 7.3 7 06/11/2006 06:20:00 12.9 1.2 15.6 9.9 13 1.2 16.4 9.5 12.6 1.3 15.6 9.1 136 8 126 165 7.1 0 7.3 7 06/11/2006 06:30:00 12.8 1.1 16.4 9.9 12.9 1.1 16.1 9.9 12.4 1.2 16.4 8.4 134 8 146 165 7.1 0 7.3 7 06/11/2006 06:40:00 13.8 1 16.4 11.5 13.9 1 16.4 10.7 13.7 1.2 16.8 10.3 137 7 126 165 7.1 0 7.3 7 06/11/2006 06:50:00 13.3 1.3 16.4 9.5 13.4 1.3 16.4 10.3 13.1 1.4 16.4 9.1 139 7 142 165 7.2 0 7.3 7.3 06/11/2006 07:00:00 13.8 1 16.4 11.1 14 1 16.8 11.5 13.5 1.2 16.4 9.9 139 7 133 165 7.3 0 7.3 7.3 06/11/2006 07:10:00 14.5 1.3 17.6 11.1 14.6 1.3 17.9 11.5 14.5 1.2 17.6 10.7 142 6 136 165 7.3 0 7.5 7.3 06/11/2006 07:20:00 14.1 1.3 17.6 10.7 14.2 1.3 17.6 10.7 14.1 1.3 17.2 8.8 141 7 145 165 7.3 0 7.5 7.3 06/11/2006 07:30:00 13.6 1.3 16.4 9.1 13.7 1.4 16.8 9.5 13.4 1.4 16.8 9.9 141 6 141 165 7.4 0 7.5 7.3 06/11/2006 07:40:00 13.8 1 16.1 11.5 13.9 1 16.4 11.1 13.5 1.1 16.4 10.7 142 6 141 165 7.4 0 7.5 7.3 06/11/2006 07:50:00 13.9 1 16.4 11.1 14 1 16.4 11.5 13.7 1 16.4 10.3 142 6 137 165 7.4 0 7.5 7.3 06/11/2006 08:00:00 14 1.2 16.8 11.1 14.1 1.3 17.2 11.1 13.9 1.2 16.8 10.7 141 6 136 165 7.4 0 7.5 7.3 06/11/2006 08:10:00 13.3 1.2 16.4 9.9 13.4 1.2 16.4 9.9 13 1.3 17.2 9.5 140 8 150 165 7.5 0 7.5 7.5 06/11/2006 08:20:00 14 1.3 17.2 10.3 14.1 1.3 17.6 10.3 13.7 1.2 16.8 10.3 141 6 143 165 7.6 0 7.8 7.5 06/11/2006 08:30:00 13.7 1.3 17.2 10.7 13.8 1.3 17.6 10.7 13.3 1.3 16.4 10.3 141 8 145 165 7.6 0 7.8 7.5 06/11/2006 08:40:00 14.2 1.3 17.9 10.3 14.3 1.3 17.6 10.7 14 1.5 18.3 10.3 142 7 143 165 7.6 0 7.8 7.5 06/11/2006 08:50:00 14.7 1.4 18.7 11.1 14.9 1.5 19.1 11.1 14.6 1.5 17.9 9.9 142 7 150 165 7.6 0 7.8 7.5 06/11/2006 09:00:00 14.3 1.3 17.2 10.3 14.5 1.3 17.6 10.3 14.1 1.5 17.2 10.3 140 6 139 165 7.6 0 7.8 7.5 06/11/2006 09:10:00 14.7 1.2 17.2 11.8 14.8 1.3 17.6 11.8 14.5 1.3 17.2 10.7 141 7 139 165 7.7 0 7.8 7.5 06/11/2006 09:20:00 14.4 1.4 17.6 10.7 14.5 1.4 17.9 9.9 14.1 1.5 17.9 10.3 138 7 136 165 7.8 0 7.8 7.8 06/11/2006 09:30:00 13.7 1.2 16.8 10.7 13.8 1.3 17.6 11.5 13.1 1.5 17.2 8.8 139 7 129 165 7.8 0 8 7.8 06/11/2006 09:40:00 14.2 1.1 17.6 10.7 14.3 1.2 17.9 10.7 14.2 1.3 17.2 10.3 139 6 139 165 7.8 0 8 7.5 06/11/2006 09:50:00 13.9 1.3 17.2 10.3 13.9 1.3 17.6 10.7 13.4 1.5 17.2 9.5 140 8 135 165 7.9 0 8 7.5 06/11/2006 10:00:00 14.1 1.3 17.2 9.9 14.2 1.3 17.6 9.5 13.9 1.2 17.9 10.7 139 8 139 165 7.9 0 8.3 7.8 06/11/2006 10:10:00 14.3 1.2 16.8 10.3 14.5 1.3 17.2 9.9 14.2 1.3 16.8 9.9 139 7 135 165 8 0 8 7.8 06/11/2006 10:20:00 14.1 1.2 17.6 10.3 14.2 1.2 17.9 10.3 13.7 1.3 17.6 9.5 139 6 141 165 8 0 8 7.8 06/11/2006 10:30:00 14.1 1.2 17.2 11.1 14.2 1.2 17.6 11.1 13.9 1.3 17.6 9.9 138 7 141 165 8 0 8 7.8 06/11/2006 10:40:00 13.8 1.3 17.6 9.9 13.9 1.3 17.9 9.9 13.4 1.4 16.8 8.4 138 7 126 165 8 0 8.3 7.8 06/11/2006 10:50:00 13.7 1.2 16.8 10.3 13.8 1.3 17.2 9.9 13.4 1.3 16.4 9.9 138 6 137 165 8.1 0 8.3 7.5 06/11/2006 11:00:00 13 1.3 16.4 8.8 13.1 1.3 16.4 9.1 12.8 1.4 16.1 8.8 137 6 138 165 8.1 0 8.3 8 06/11/2006 11:10:00 12.9 1.3 15.6 9.1 13 1.3 16.8 8.8 12.7 1.3 16.1 9.5 136 8 138 165 8.1 0 8.3 8 06/11/2006 11:20:00 13.3 1.2 16.4 10.3 13.4 1.2 16.8 10.3 13.1 1.3 16.1 9.9 136 6 137 165 8.1 0 8.3 8 06/11/2006 11:30:00 13.4 1.1 16.4 10.3 13.5 1.1 16.8 10.3 13.1 1.3 16.1 8.8 135 7 116 165 8.1 0 8.3 8 06/11/2006 11:40:00 13.3 1.1 15.6 9.5 13.4 1.2 16.1 9.9 13.1 1.2 17.6 9.5 135 7 132 165 8.1 0 8.3 8 06/11/2006 11:50:00 12.5 1.1 16.1 8.4 12.6 1.2 16.1 8.8 12.2 1.2 15.6 9.5 136 7 137 165 8.2 0 8.3 8 06/11/2006 12:00:00 13.3 1.2 17.2 10.7 13.4 1.3 17.9 10.7 12.9 1.5 16.4 9.1 135 7 124 165 8.1 0 8.3 8 06/11/2006 12:10:00 14 1.1 16.4 11.5 14.2 1.1 16.8 11.1 13.7 1.2 16.8 10.3 137 7 126 165 8 0 8.3 8 06/11/2006 12:20:00 13.9 1.1 17.2 10.7 14 1.1 17.2 10.7 13.5 1.3 17.2 10.3 135 6 129 165 8 0 8.3 8 06/11/2006 12:30:00 13.3 1.1 15.6 9.9 13.5 1.1 16.1 9.9 13.1 1.3 16.1 9.1 135 7 143 165 8 0 8.3 8 06/11/2006 12:40:00 13.4 1.2 16.8 10.3 13.5 1.2 16.8 10.3 13.1 1.3 16.8 9.5 135 7 138 165 8 0 8.3 8 06/11/2006 12:50:00 13.1 1.1 16.1 9.5 13.2 1.1 16.4 9.5 12.9 1.2 16.4 8.8 137 7 121 165 8.1 0 8.3 8 06/11/2006 13:00:00 12.6 1.3 16.1 9.1 12.8 1.3 16.1 9.5 12.4 1.3 16.4 9.9 138 7 135 165 8.1 0 8.5 8 06/11/2006 13:10:00 12.2 1.1 14.9 9.5 12.2 1.1 14.9 9.5 12 1.1 14.9 8.8 137 6 138 165 8.2 0 8.3 7.5 06/11/2006 13:20:00 12.1 1.1 14.9 9.1 12.2 1.2 15.3 9.1 11.7 1.2 14.5 8.8 136 6 138 165 8.2 0 8.3 7.5 06/11/2006 13:30:00 12 1.2 15.6 9.1 12.1 1.2 15.3 8.4 11.7 1.1 14.9 8.8 137 6 142 165 8.2 0 8.3 7.5 06/11/2006 13:40:00 12.4 1 15.6 9.5 12.5 1 15.6 9.5 12.2 1.2 15.6 8.8 136 6 139 165 8.1 0 8.3 7.5 06/11/2006 13:50:00 12.4 1.2 15.6 8.8 12.5 1.2 16.1 9.1 12.2 1.3 14.9 8.4 136 6 135 165 8.2 0 8.3 7.5 06/11/2006 14:00:00 12 1.1 15.3 9.1 12.1 1.1 15.3 9.1 11.8 1.3 15.6 7.6 137 7 129 165 8.2 0 8.3 7.5 06/11/2006 14:10:00 12 1 14.9 8.8 12.1 1.1 14.9 8.4 11.5 1.1 14.5 8 134 6 133 165 8.2 0 8.5 7.5 06/11/2006 14:20:00 11.2 1 13.7 8.8 11.4 1.1 14.1 8.8 11 1.2 14.1 8 133 6 129 165 8.2 0 8.5 7.5 06/11/2006 14:30:00 10.9 0.9 13.3 8.4 11 1 13.7 8.8 10.5 1.1 13 6.8 135 7 133 165 8.2 0 8.3 7.5 06/11/2006 14:40:00 10.9 1 13.7 7.6 11 1.1 14.5 7.6 10.6 1.2 13.7 6.5 133 7 139 165 8.2 0 8.3 7.5 06/11/2006 14:50:00 11 1.1 13.7 8 11.1 1.1 14.1 8.4 10.8 1.2 14.1 8 133 7 133 165 8.2 0 8.3 7.5 06/11/2006 15:00:00 10.7 1 13.3 8 10.8 1.1 13.7 7.6 10.4 1.1 13.3 7.2 132 7 129 165 8.1 0 8.5 7.5 06/11/2006 15:10:00 10.2 1.1 13 8 10.3 1.1 13.3 7.6 10 1.3 13 6.5 132 7 129 165 8.2 0 8.3 7.5 06/11/2006 15:20:00 10.1 1 12.2 7.6 10.2 1 12.6 7.2 9.9 1.1 12.6 6.8 133 7 128 165 8.2 0 8.3 7.5 06/11/2006 15:30:00 10.2 1.2 13.7 6.8 10.3 1.3 13.7 6.5 10.1 1.3 13.7 6.8 135 7 129 165 8.2 0 8.3 8 06/11/2006 15:40:00 10.6 0.9 13.7 8 10.7 0.9 13.7 8 10.4 1.1 14.1 7.6 134 8 118 165 8.1 0 8.3 8 06/11/2006 15:50:00 10.4 1 12.6 7.6 10.5 1 12.6 7.6 10.1 1.2 13 7.2 132 6 127 165 8.1 0 8.3 8 06/11/2006 16:00:00 10 0.8 12.6 7.6 10.1 0.8 12.6 8 9.8 0.9 12.2 7.2 132 8 135 165 8.1 0 8.5 8 06/11/2006 16:10:00 9.8 0.9 12.2 7.6 9.9 1 12.2 7.6 9.4 1.1 12.2 6.5 133 7 128 165 8.2 0 8.3 8.3 06/11/2006 16:20:00 10.4 1 13 7.2 10.5 1 13 7.2 10.1 1.1 13 7.2 131 6 128 165 8.1 0 8.3 8 06/11/2006 16:30:00 9.7 1.1 12.2 6.8 9.8 1.2 12.6 6.5 9.4 1.2 12.6 6.1 132 7 126 165 8 0 8.3 8 06/11/2006 16:40:00 9.7 1 13 7.2 9.7 1 13 7.2 9.5 1 11.8 6.8 133 8 130 165 8 0 8.3 8 06/11/2006 16:50:00 9.7 0.9 12.2 7.6 9.9 1 12.6 7.6 9.5 1 12.6 6.8 132 6 130 165 8 0 8.3 7.8 06/11/2006 17:00:00 10.2 1.1 13 6.8 10.3 1.1 13.3 6.8 10 1.1 13 7.6 131 7 128 165 8 0 8.3 8 06/11/2006 17:10:00 10.2 1 13 8 10.3 1 13.3 8.4 10 1.1 13.7 7.2 131 6 130 165 8 0 8 8 06/11/2006 17:20:00 9.7 1.1 12.6 6.8 9.8 1.1 12.6 7.2 9.3 1.2 12.2 6.5 132 8 144 165 8 0 8.3 8 06/11/2006 17:30:00 9.7 0.9 11.8 7.2 9.8 1 12.2 6.8 9.6 1.1 12.2 6.8 130 7 122 165 8 0 8 8 06/11/2006 17:40:00 9.8 1 12.2 7.2 9.9 1 12.2 7.2 9.5 1.1 12.2 6.5 134 8 132 165 8 0 8.3 8 06/11/2006 17:50:00 9.5 1.5 13 5.7 9.6 1.5 12.6 5.7 9.2 1.5 13 5.7 131 7 135 165 8 0 8.3 7.8 06/11/2006 18:00:00 10.1 1 12.2 7.2 10.2 1 12.2 6.8 9.8 1 12.2 6.8 132 7 128 165 8 0 8.3 7.8 06/11/2006 18:10:00 9.3 1.1 11.5 6.5 9.4 1.1 11.8 6.1 9 1.2 11.5 5.7 131 7 141 165 8 0 8.3 7.8 06/11/2006 18:20:00 9.4 1.2 12.2 6.1 9.5 1.3 12.6 6.5 9 1.3 12.6 6.1 131 7 128 165 8 0 8.3 7.5 06/11/2006 18:30:00 9.2 0.9 11.8 7.2 9.3 1 11.8 7.2 9 0.9 11.5 6.8 129 6 131 165 8 0.1 8 7.5 06/11/2006 18:40:00 9.5 1.1 13 6.8 9.7 1.2 13 6.8 9.3 1.2 12.6 6.1 127 6 136 165 8 0.1 8 7.5 06/11/2006 18:50:00 8.8 1.2 12.6 6.5 8.9 1.3 12.6 6.5 8.6 1.2 11.5 5.7 127 7 122 165 8 0.1 8 7.5 06/11/2006 19:00:00 8.8 1.2 11.1 6.1 8.9 1.2 11.5 6.1 8.6 1.2 11.5 5.3 127 6 128 165 8 0.1 8.5 7.5 06/11/2006 19:10:00 8.8 1 11.1 5.7 8.9 1 11.5 6.1 8.6 1 11.1 5.7 129 8 130 165 8 0.1 8 7.5 06/11/2006 19:20:00 8.2 1 10.7 4.9 8.3 1.1 11.1 4.9 8.1 1.1 10.3 5.3 132 8 139 165 8 0 8 7.5 06/11/2006 19:30:00 8.7 0.7 10.7 7.2 8.8 0.7 11.1 6.8 8.5 0.8 10.3 6.1 127 6 126 165 8 0 8 7.8 06/11/2006 19:40:00 8.5 0.9 10.7 5.7 8.6 0.9 11.5 5.7 8.4 1 11.1 5.7 127 6 112 165 8 0 8 7.8 06/11/2006 19:50:00 8.6 0.8 10.7 6.8 8.7 0.9 11.1 6.8 8.6 0.8 10.7 6.5 130 7 124 165 8 0 8 7.5 06/11/2006 20:00:00 9 1 11.1 5.3 9.1 1.1 11.1 5.7 8.8 1 11.5 5.7 126 6 121 165 8 0 8.5 7.8 06/11/2006 20:10:00 8.8 0.7 11.1 7.2 8.9 0.7 10.7 7.2 8.7 0.8 10.7 6.1 129 6 130 165 8 0 8 7.8 06/11/2006 20:20:00 9.1 0.8 11.1 6.8 9.1 0.8 11.1 7.2 8.9 0.9 11.1 6.8 131 5 128 165 8 0 8 7.8 06/11/2006 20:30:00 8.9 0.7 10.7 7.2 9 0.7 10.7 6.8 8.8 0.8 10.7 6.1 132 6 122 165 8 0 8 7.8 06/11/2006 20:40:00 8.8 0.7 11.1 6.8 8.8 0.8 11.1 6.8 8.7 0.7 10.3 6.8 135 6 142 165 8 0 8 7.8 06/11/2006 20:50:00 9.6 0.8 11.8 7.6 9.6 0.9 11.8 7.6 9.4 0.9 11.8 6.8 136 6 129 165 8 0 8 7.8 06/11/2006 21:00:00 9.4 0.8 11.5 7.2 9.4 0.8 11.5 7.2 9.1 1 11.5 6.1 135 6 136 165 8 0 8 7.8 06/11/2006 21:10:00 9.4 0.8 11.5 7.6 9.5 0.9 11.5 7.6 9.2 0.8 11.1 6.8 138 6 138 165 8 0 8 7.8 06/11/2006 21:20:00 9.2 1 11.5 6.1 9.3 1 11.5 6.1 9.1 1 12.2 5.7 139 6 128 165 8 0 8 7.8 06/11/2006 21:30:00 9.8 0.9 11.8 7.2 9.7 1 11.8 7.2 9.5 1 12.2 6.5 139 6 142 165 8 0 8 7.8 06/11/2006 21:40:00 9.5 0.9 11.5 6.5 9.5 1 11.5 6.1 9.5 0.9 11.5 7.2 138 6 140 165 8 0 8 7.8 06/11/2006 21:50:00 9.4 0.7 11.1 7.2 9.4 0.8 11.5 7.2 9.3 0.8 11.5 6.5 138 5 139 165 8 0 8 7.8 06/11/2006 22:00:00 8.7 0.8 10.7 6.5 8.8 0.8 10.7 6.5 8.5 0.9 10.7 6.5 137 5 139 165 8 0 8.5 7.8 06/11/2006 22:10:00 8.6 0.8 10.3 6.8 8.6 0.8 10.7 6.5 8.4 0.8 10.3 6.5 138 5 132 165 8 0 8 7.8 06/11/2006 22:20:00 8.5 0.7 10.3 6.8 8.6 0.7 10.7 6.5 8.5 0.7 10.3 6.5 139 5 125 165 8 0 8 7.8 06/11/2006 22:30:00 7.7 0.9 9.9 5.7 7.8 0.9 9.9 5.7 7.7 1 10.3 5.3 136 7 143 165 8 0 8 7.8 06/11/2006 22:40:00 8.3 0.8 9.9 6.5 8.3 0.8 9.9 6.5 8.1 0.9 9.9 5.7 132 5 129 165 8 0 8 7.8 06/11/2006 22:50:00 8.2 0.8 10.3 6.1 8.2 0.8 10.7 6.1 8 0.8 9.9 5.3 134 7 136 165 8 0 8 7.8 06/11/2006 23:00:00 8.9 0.9 10.7 6.5 8.9 0.9 10.3 6.5 8.9 0.8 10.3 6.8 141 6 141 165 8 0 8 7.8 06/11/2006 23:10:00 8.8 0.8 11.1 6.8 8.8 0.8 10.7 6.5 8.6 0.9 10.7 6.1 139 6 139 165 8 0 8 7.8 06/11/2006 23:20:00 8 0.9 10.3 5.7 8 0.9 10.3 5.3 8 0.9 9.9 5.3 141 6 131 165 8 0 8 7.8 06/11/2006 23:30:00 7.5 0.8 9.5 4.6 7.6 0.8 9.5 4.6 7.5 0.9 9.9 5.3 138 6 142 165 8 0 8 7.8 06/11/2006 23:40:00 6.9 0.9 8.8 4.6 6.9 0.9 8.8 4.6 6.8 0.9 9.1 4.6 138 7 139 165 8 0 8 7.8 06/11/2006 23:50:00 6.7 0.5 8 4.9 6.8 0.5 8 5.3 6.6 0.7 8 4.9 135 6 132 165 8 0 8 7.8 06/12/2006 00:00:00 6.5 0.7 8.4 4.9 6.5 0.6 8 4.9 6.5 0.6 8.4 4.9 139 5 139 165 8 0 8 7.8 06/12/2006 00:10:00 7.7 0.6 9.1 5.7 7.7 0.6 9.1 6.1 7.7 0.6 9.1 5.3 137 5 139 165 8 0 8 7.8 06/12/2006 00:20:00 6.9 0.7 8.8 4.9 6.9 0.7 8.8 4.9 6.9 0.7 9.1 5.3 137 5 137 165 8 0 8 7.8 06/12/2006 00:30:00 6.9 0.6 8 5.3 7 0.6 8.4 5.7 6.9 0.7 8.8 5.3 138 4 135 165 8 0 8 7.8 06/12/2006 00:40:00 7.1 0.5 8 5.3 7.1 0.5 8.4 5.3 7 0.7 8.8 4.2 135 4 135 165 8 0 8 7.8 06/12/2006 00:50:00 6.1 0.5 7.6 4.6 6.2 0.5 7.6 4.2 6 0.5 7.2 4.2 134 5 132 165 8 0 8 7.8 06/12/2006 01:00:00 6.8 0.8 8.8 4.6 6.9 0.8 8.8 4.9 6.8 0.7 8.8 4.9 140 6 128 165 8 0 8 7.8 06/12/2006 01:10:00 6.7 0.8 8.8 4.2 6.8 0.8 8.4 3.8 6.7 0.8 8.4 4.9 137 5 136 165 8 0 8 7.8 06/12/2006 01:20:00 5.6 0.5 6.8 4.6 5.6 0.5 7.2 4.6 5.7 0.5 7.2 4.2 139 4 134 165 8 0 8 7.8 06/12/2006 01:30:00 5.5 0.6 6.8 4.2 5.6 0.6 6.8 4.6 5.5 0.6 7.2 3.4 137 4 136 165 8 0 8 7.8 06/12/2006 01:40:00 5.1 0.6 6.5 3 5.2 0.6 6.8 3 5.1 0.6 6.5 3.4 139 5 139 165 8 0 8 7.8 06/12/2006 01:50:00 5.3 0.6 6.8 3.4 5.4 0.6 6.8 3.4 5.3 0.7 6.8 3.4 138 5 141 165 8 0 8 7.8 06/12/2006 02:00:00 5.8 0.5 7.2 4.6 5.8 0.5 7.2 4.2 5.7 0.5 6.8 4.2 138 4 139 165 8 0 8 7.8 06/12/2006 02:10:00 6.1 0.6 7.2 4.6 6.2 0.5 7.2 4.6 6.1 0.6 7.2 4.2 135 4 141 165 8 0 8 7.8 06/12/2006 02:20:00 5.3 0.4 6.5 4.2 5.4 0.4 6.8 4.6 5.5 0.4 6.5 4.2 135 4 134 165 8 0 8 7.8 06/12/2006 02:30:00 5.4 0.6 6.8 3.4 5.5 0.5 6.8 3.8 5.6 0.6 6.8 3.8 135 5 140 165 8 0 8 7.8 06/12/2006 02:40:00 5 0.4 6.1 3.8 5 0.3 5.7 3.8 5.2 0.4 6.1 4.2 142 5 142 165 8 0 8 7.8 06/12/2006 02:50:00 4.9 0.4 5.7 3.8 5 0.4 5.7 4.2 4.9 0.4 6.1 3.8 137 4 144 165 8 0 8 7.8 06/12/2006 03:00:00 4.1 0.8 5.7 2.3 4.2 0.8 5.7 2.3 4.3 0.9 5.7 2.3 133 6 138 165 8 0 8 7.8 06/12/2006 03:10:00 2.9 0.3 3.4 2.3 3 0.3 3.8 2.3 3.2 0.3 3.8 2.6 130 5 125 165 8 0 8 7.8 06/12/2006 03:20:00 3.7 0.4 4.6 2.6 3.9 0.4 4.6 2.6 3.9 0.3 4.9 3 131 3 127 165 8 0 8 7.8 06/12/2006 03:30:00 4.3 0.3 4.9 3.4 4.4 0.3 5.3 3.4 4.4 0.3 5.3 3.4 136 5 130 165 8 0 8 7.8 06/12/2006 03:40:00 3.7 0.4 4.6 2.6 3.8 0.4 4.9 3 4 0.4 4.9 3 140 4 142 165 8 0 8 7.8 06/12/2006 03:50:00 3 0.5 4.2 1.9 3.1 0.6 4.2 1.9 3.3 0.5 4.2 2.3 133 4 139 165 8 0 8 7.8 06/12/2006 04:00:00 2.6 0.3 3.4 1.9 2.6 0.4 3 1.5 2.9 0.3 3.4 1.9 134 3 136 165 8 0 8 7.8 06/12/2006 04:10:00 3.2 0.3 3.8 2.3 3.3 0.3 3.8 2.6 3.5 0.3 4.2 2.6 133 2 135 165 8 0 8 7.8 06/12/2006 04:20:00 3.4 0.4 4.2 2.6 3.5 0.4 4.6 2.6 3.6 0.4 4.6 2.6 134 3 135 165 8 0 8 7.8 06/12/2006 04:30:00 4.3 0.3 4.9 3.4 4.4 0.3 5.3 3.4 4.4 0.3 4.9 3.8 140 3 142 165 8 0 8 7.8 06/12/2006 04:40:00 3.5 0.5 4.6 2.6 3.6 0.5 4.6 2.6 3.7 0.6 4.9 2.3 137 4 140 165 8 0 8 7.8 06/12/2006 04:50:00 1.4 0.7 3 0.4 1.4 0.8 3 0.4 1.8 0.6 3.4 0.4 137 6 138 165 8 0 8 7.8 06/12/2006 05:00:00 2.5 0.4 3.4 1.5 2.6 0.4 3.4 1.5 2.8 0.4 3.4 1.9 140 3 141 165 8 0 8.5 8 06/12/2006 05:10:00 3.3 0.2 3.8 2.6 3.4 0.2 4.2 2.6 3.5 0.2 4.2 3 140 3 140 165 8 0 8.3 8 06/12/2006 05:20:00 2.2 0.4 3.4 1.5 2.3 0.4 3.4 1.5 2.5 0.4 3.8 1.5 134 5 142 165 8 0 8.3 8 06/12/2006 05:30:00 1.6 0.2 2.3 1.1 1.8 0.2 2.6 1.1 2.1 0.2 2.6 1.5 134 6 129 165 8 0 8.3 8 06/12/2006 05:40:00 2.1 0.4 2.6 1.5 2.4 0.3 3 1.5 2.5 0.4 3.4 1.9 137 4 135 165 8.1 0 8.3 8 06/12/2006 05:50:00 2.4 0.2 3 1.9 2.5 0.2 3 1.9 2.8 0.3 3.4 2.3 140 4 135 165 8.1 0 8.3 8 06/12/2006 06:00:00 2.5 0.2 3 1.9 2.6 0.2 3.4 1.9 3 0.2 3.4 2.3 143 4 138 165 8.1 0 8.3 8 06/12/2006 06:10:00 2.2 0.3 3 1.5 2.2 0.3 3 1.5 2.6 0.3 3.4 1.9 141 3 140 165 8 0 8.3 8 06/12/2006 06:20:00 1.6 0.3 2.3 0.7 1.7 0.2 2.3 1.1 2.1 0.3 2.6 1.5 140 3 142 165 8 0 8.3 8 06/12/2006 06:30:00 1.8 0.2 2.3 1.1 2 0.2 2.3 1.1 2.2 0.2 2.6 1.5 146 4 145 165 8.1 0 8.3 8 06/12/2006 06:40:00 1.8 0.3 2.3 1.1 1.9 0.3 2.6 1.1 2.2 0.3 3 1.5 153 5 155 165 8.2 0 8.3 8 06/12/2006 06:50:00 1.5 0.5 2.6 0.7 1.6 0.4 2.6 0.7 1.9 0.5 2.6 0.7 157 7 162 165 8.2 0 8.5 8 06/12/2006 07:00:00 1.5 0.2 1.9 1.1 1.6 0.2 1.9 1.1 1.7 0.2 2.3 1.1 128 4 133 165 8.4 0.1 8.5 8.3 06/12/2006 07:10:00 1.8 0.3 2.6 1.1 1.9 0.3 3 1.5 2 0.3 3 1.5 121 6 128 165 8.5 0 8.8 8.5 06/12/2006 07:20:00 2.3 0.3 3 1.5 2.5 0.3 3.4 1.5 2.6 0.3 3.4 1.9 125 6 119 165 8.7 0 8.8 8.5 06/12/2006 07:30:00 2.3 0.3 3.4 1.5 2.5 0.3 3.4 1.5 2.7 0.3 3.8 1.9 129 6 135 165 8.7 0 9 8.3 06/12/2006 07:40:00 2.3 0.3 3 1.1 2.4 0.3 3 1.5 2.8 0.3 3.4 1.9 135 4 136 165 8.6 0.1 8.8 8.3 06/12/2006 07:50:00 2.6 0.3 3 1.9 2.7 0.3 3.4 1.9 3.1 0.3 3.8 2.3 135 4 130 165 8.6 0 8.8 8.3 06/12/2006 08:00:00 3.4 0.4 4.6 2.6 3.5 0.4 4.6 2.6 3.7 0.4 4.6 3 140 3 140 165 8.5 0 9 8.3 06/12/2006 08:10:00 3.5 0.3 4.2 2.6 3.5 0.3 4.2 2.6 3.7 0.3 4.6 3 140 5 142 165 8.5 0 8.8 8 06/12/2006 08:20:00 3.6 0.3 4.6 3 3.6 0.3 4.2 2.6 3.8 0.3 4.6 3 141 3 141 165 8.5 0.1 8.8 8.3 06/12/2006 08:30:00 3.7 0.3 4.6 3 3.7 0.3 4.6 3 4 0.3 4.9 3.4 146 3 151 165 8.5 0.1 8.5 7.8 06/12/2006 08:40:00 3.6 0.4 4.2 2.6 3.6 0.4 4.6 2.6 3.9 0.4 4.6 3 146 3 144 165 8.4 0 8.5 7.8 06/12/2006 08:50:00 3.1 0.2 3.8 2.3 3.1 0.2 3.8 2.3 3.4 0.2 4.2 2.6 142 4 139 165 8.5 0.1 8.8 8 06/12/2006 09:00:00 3 0.3 3.8 1.5 3 0.3 3.8 1.5 3.4 0.3 4.2 2.3 143 5 138 165 8.7 0 8.8 8.3 06/12/2006 09:10:00 3.6 0.4 4.2 2.6 3.6 0.3 4.2 2.6 3.9 0.4 4.6 2.6 149 5 139 165 8.9 0 9 8.5 06/12/2006 09:20:00 3.8 0.4 4.6 2.6 3.7 0.3 4.6 3 4 0.4 4.9 3 148 4 152 165 9 0 9 8.8 06/12/2006 09:30:00 4.4 0.3 5.3 3.4 4.4 0.3 5.3 3.4 4.7 0.3 5.7 3.8 148 5 161 165 8.9 0 9 8.5 06/12/2006 09:40:00 4.2 0.3 4.9 3.4 4.2 0.3 4.9 3.4 4.5 0.3 5.3 3.8 146 5 151 165 8.9 0 9 8.8 06/12/2006 09:50:00 3.9 0.4 4.9 2.6 4 0.4 4.9 2.6 4.3 0.4 5.3 2.6 144 6 148 165 9.2 0 9.6 8.8 06/12/2006 10:00:00 4.3 0.4 5.3 3.4 4.3 0.4 5.3 3.4 4.7 0.4 5.7 3.4 150 6 148 165 9.1 0.1 9.3 8.5 06/12/2006 10:10:00 4.3 0.4 4.9 2.6 4.3 0.4 4.9 3 4.6 0.4 5.3 3.4 146 3 142 165 9 0.1 9.3 8.5 06/12/2006 10:20:00 3.8 0.3 4.6 3 3.8 0.3 4.6 3 4.2 0.3 4.9 3.4 146 4 147 165 9 0.1 9.3 8.8 06/12/2006 10:30:00 3.7 0.4 4.6 2.6 3.7 0.4 4.6 2.6 4.1 0.3 4.9 3.4 149 7 160 165 9 0.1 9.3 8.5 06/12/2006 10:40:00 3.8 0.4 4.9 2.6 3.8 0.4 5.3 3 4 0.4 5.3 3.4 143 6 151 165 9.2 0 9.6 8.8 06/12/2006 10:50:00 4.4 0.3 5.3 3.4 4.5 0.3 5.3 3.8 4.6 0.3 5.7 3.4 142 6 148 165 9.4 0 9.6 8.8 06/12/2006 11:00:00 4.5 0.3 5.3 3.4 4.6 0.3 5.3 3.4 4.7 0.3 5.3 3.8 142 5 141 165 9.3 0 9.6 8.8 06/12/2006 11:10:00 4.1 0.4 5.3 3 4.1 0.4 4.9 3 4.4 0.4 5.3 3.4 145 5 145 165 9.3 0 9.6 8.8 06/12/2006 11:20:00 4.5 0.4 5.7 3.4 4.5 0.4 5.7 3.4 4.6 0.4 6.1 3.8 138 6 114 165 9.3 0 9.6 8.8 06/12/2006 11:30:00 4.7 0.3 5.7 3.8 4.8 0.3 5.7 3.8 4.9 0.4 5.7 3.8 133 5 128 165 9.4 0 9.6 8.8 06/12/2006 11:40:00 4.9 0.3 5.7 4.2 5 0.3 5.7 4.2 5.1 0.3 6.1 4.2 131 3 131 165 9.2 0 9.6 8.8 06/12/2006 11:50:00 4 0.4 4.9 3 4.1 0.4 5.3 3 4.3 0.4 5.3 3.4 132 6 130 165 9.5 0 9.6 9 06/12/2006 12:00:00 3.8 0.4 4.6 2.6 3.8 0.4 4.9 2.6 4.1 0.3 5.3 3.4 148 8 133 165 9.2 0.2 9.6 8.8 06/12/2006 12:10:00 4.7 0.5 6.1 3.4 4.7 0.5 6.1 3.4 4.9 0.5 6.1 3.4 143 6 139 165 9 0.1 9.3 8.8 06/12/2006 12:20:00 4.2 0.5 5.3 2.6 4.3 0.5 5.3 2.6 4.4 0.5 5.3 2.6 139 7 138 165 9 0.1 9.3 8.5 06/12/2006 12:30:00 3.9 0.5 5.3 2.6 3.9 0.5 5.3 2.6 4 0.5 5.3 3 139 7 145 165 9 0.1 9.6 8.5 06/12/2006 12:40:00 3.8 0.6 4.9 1.1 3.9 0.6 4.9 0.7 4.1 0.6 5.3 2.3 140 7 145 165 9.1 0.1 9.3 8.8 06/12/2006 12:50:00 4 0.7 5.7 2.3 4.1 0.6 5.7 2.3 4.2 0.6 6.1 2.6 133 8 144 165 9 0.2 9.3 8.5 06/12/2006 13:00:00 4.5 0.7 5.7 3 4.5 0.7 6.1 3 4.7 0.6 6.1 3 145 7 124 165 8.9 0.2 9.6 8.5 06/12/2006 13:10:00 4.1 0.5 5.3 3 4.2 0.5 5.3 3 4.3 0.5 5.7 3 143 6 143 165 8.9 0.1 9 8.5 06/12/2006 13:20:00 4.6 0.5 5.7 3 4.7 0.5 5.7 3.4 4.8 0.5 6.1 3 144 6 143 165 8.9 0.2 9.3 8.5 06/12/2006 13:30:00 4.5 0.6 5.3 2.6 4.5 0.6 5.3 2.6 4.8 0.6 5.7 3.4 148 7 150 165 8.9 0.2 9.6 8.5 06/12/2006 13:40:00 4.9 0.6 6.5 3 5 0.6 6.5 3 5.3 0.5 6.8 3.8 147 8 150 165 9.2 0 9.6 8.8 06/12/2006 13:50:00 4.8 0.6 7.2 3 4.8 0.6 6.8 2.6 5 0.6 6.8 3 152 10 165 165 9 0.2 9.8 8.5 06/12/2006 14:00:00 4.6 0.4 5.7 3.4 4.6 0.4 5.7 3.4 4.8 0.5 6.1 3.4 148 6 127 165 9.2 0.1 9.6 8.5 06/12/2006 14:10:00 4.1 0.3 4.9 3.4 4.2 0.3 5.3 3.4 4.5 0.3 5.3 3.8 142 3 145 165 9.4 0.2 9.6 9 06/12/2006 14:20:00 4 0.3 4.9 3 4 0.3 4.9 3 4.2 0.3 4.9 3 144 5 144 165 9.6 0.1 9.8 9 06/12/2006 14:30:00 3.9 0.6 5.3 2.6 3.9 0.5 5.3 2.6 4.1 0.6 5.3 2.6 138 10 136 165 9.9 0 10.1 9.6 06/12/2006 14:40:00 3.8 0.5 4.9 1.9 3.8 0.5 4.9 1.9 4.2 0.4 5.3 3 142 9 149 165 10 0.2 10.6 9.6 06/12/2006 14:50:00 2.9 0.6 4.6 1.1 2.9 0.6 4.6 1.1 3.3 0.5 4.6 2.3 130 16 115 165 10.3 0.1 11.1 10.1 06/12/2006 15:00:00 2.8 0.4 4.2 1.9 2.9 0.4 4.2 1.9 3.3 0.5 4.6 1.9 123 9 113 165 10.9 0.6 11.7 9.8 06/12/2006 15:10:00 3 0.5 4.2 1.5 3.1 0.5 4.2 1.5 3.4 0.5 4.9 2.3 130 8 134 165 11.5 0.1 11.9 10.9 06/12/2006 15:20:00 2.8 0.5 4.2 1.9 3 0.5 4.6 2.3 3.3 0.5 4.9 1.9 131 9 135 165 11.3 0.3 12.2 10.6 06/12/2006 15:30:00 3.6 0.6 4.9 2.3 3.7 0.6 5.3 2.6 4 0.6 5.3 3 131 7 136 165 11.3 0.2 11.7 10.9 06/12/2006 15:40:00 3.3 0.6 4.9 1.5 3.5 0.6 5.3 1.9 3.8 0.6 5.7 2.3 126 8 122 165 11.2 0.2 11.7 10.3 06/12/2006 15:50:00 3.3 0.6 4.9 1.9 3.4 0.6 4.6 2.3 3.7 0.5 4.9 2.6 134 7 165 165 11.5 0 11.9 11.1 06/12/2006 16:00:00 2.9 0.7 4.6 0.7 3.1 0.7 4.9 0.7 3.4 0.5 5.3 2.3 124 16 118 165 11.6 0 11.9 11.4 06/12/2006 16:10:00 2.7 0.6 4.2 0.7 2.9 0.6 4.2 1.1 3.3 0.5 5.3 1.9 120 8 123 165 11.3 0.2 11.7 10.9 06/12/2006 16:20:00 3.3 0.4 4.2 2.3 3.4 0.4 4.6 2.3 3.6 0.4 4.6 2.6 125 8 122 165 11.1 0.2 11.4 10.6 06/12/2006 16:30:00 2.9 0.5 4.2 1.9 3.2 0.5 4.6 2.3 3.2 0.5 4.6 2.3 128 8 123 165 10.9 0.2 11.4 10.3 06/12/2006 16:40:00 2.4 0.4 3.4 1.5 2.9 0.4 3.8 1.9 2.9 0.4 3.8 1.5 121 9 116 165 11.3 0 11.4 10.9 06/12/2006 16:50:00 1.7 0.5 3.4 0.7 2.3 0.5 3.8 1.5 2.3 0.5 4.2 1.5 115 6 116 165 11.3 0.1 11.4 10.9 06/12/2006 17:00:00 1.6 0.5 3 0.4 2.2 0.5 3.4 1.1 2.3 0.4 3.4 1.1 110 11 116 165 11.6 0.2 11.9 10.9 06/12/2006 17:10:00 2.2 0.4 3.4 1.1 2.6 0.4 3.8 1.9 2.8 0.4 3.8 1.5 112 9 103 165 11.3 0.2 11.7 10.9 06/12/2006 17:20:00 1.9 0.4 2.6 0.7 2.4 0.3 3 1.1 2.6 0.3 3.8 1.9 118 8 114 165 11.1 0 11.4 10.9 06/12/2006 17:30:00 1.5 0.4 2.6 0.4 2 0.4 3 1.1 2.2 0.4 3 1.1 112 8 98 165 11.1 0 11.4 10.9 06/12/2006 17:40:00 2.1 0.5 3 0.7 2.6 0.5 3.4 1.5 2.5 0.4 3.8 1.5 112 6 121 165 10.9 0 11.1 10.9 06/12/2006 17:50:00 2.2 0.5 3.4 0.7 2.6 0.5 3.8 1.5 2.6 0.5 3.8 1.1 114 8 128 165 10.7 0 11.1 10.6 06/12/2006 18:00:00 1.7 0.3 2.6 0.7 2.2 0.3 3 1.1 2.3 0.3 3 1.5 106 9 104 165 10.7 0 10.9 10.9 06/12/2006 18:10:00 1 0.4 2.3 0.4 1.6 0.4 2.6 0.7 1.7 0.4 2.6 0.7 92 8 94 165 10.9 0 11.1 10.9 06/12/2006 18:20:00 0.7 0.4 1.5 0.4 1.1 0.5 1.9 0.4 1.2 0.4 1.9 0.4 93 9 87 165 11.1 0 11.4 10.9 06/12/2006 18:30:00 0.5 0.3 1.5 0.4 0.7 0.5 1.9 0.4 0.8 0.6 2.3 0.4 99 1 98 165 11.3 0 11.7 11.1 06/12/2006 18:40:00 0.5 0.3 1.5 0.4 0.7 0.5 1.9 0.4 1 0.6 2.3 0.4 89 22 98 165 11.3 0 11.7 11.4 06/12/2006 18:50:00 1 0.6 3 0.4 1.3 0.6 3 0.4 1.4 0.5 2.6 0.4 60 19 52 165 11.7 0.1 12.2 11.1 06/12/2006 19:00:00 0.6 0.4 2.3 0.4 0.7 0.5 2.3 0.4 0.9 0.5 2.6 0.4 119 19 119 165 11.9 0.1 12.2 11.7 06/12/2006 19:10:00 0.8 0.4 2.3 0.4 1 0.6 2.6 0.4 1.2 0.6 2.6 0.4 133 17 138 165 11.7 0 11.9 11.4 06/12/2006 19:20:00 1.2 0.5 2.3 0.4 1.6 0.5 3 0.4 1.8 0.5 3 0.4 132 9 135 165 11.3 0 11.7 11.1 06/12/2006 19:30:00 0.7 0.4 1.5 0.4 1.1 0.5 1.9 0.4 1.3 0.5 2.3 0.4 113 6 122 165 11.1 0 11.4 10.9 06/12/2006 19:40:00 0.4 0 0.4 0.4 0.4 0.1 1.1 0.4 0.4 0.1 1.1 0.4 118 30 165 165 11.1 0 11.4 10.9 06/12/2006 19:50:00 0.4 0.2 1.1 0.4 0.5 0.2 1.5 0.4 0.6 0.4 1.5 0.4 271 102 4 165 11 0 11.1 10.9 06/12/2006 20:00:00 0.4 0.2 1.5 0.4 0.4 0.2 1.1 0.4 0.6 0.4 1.9 0.4 28 4 22 165 10.7 0.1 11.1 10.3 06/12/2006 20:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 31 0 165 165 10.7 0.1 10.9 10.3 06/12/2006 20:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 31 0 165 165 10.7 0 11.1 10.6 06/12/2006 20:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0.1 1.1 0.4 40 21 165 165 10.6 0.1 10.9 10.3 06/12/2006 20:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 100 9 165 165 10.4 0 10.9 10.1 06/12/2006 20:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 106 0 165 165 10.3 0 10.6 9.8 06/12/2006 21:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 106 0 165 165 10.3 0 10.6 9.8 06/12/2006 21:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 106 0 165 165 10.4 0 10.9 9.6 06/12/2006 21:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 106 0 165 165 10.3 0.1 10.6 9.6 06/12/2006 21:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0.1 1.1 0.4 109 13 165 165 10.2 0.1 10.6 9.6 06/12/2006 21:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 164 0 165 165 10 0 10.3 9.6 06/12/2006 21:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 164 0 165 165 9.8 0 10.1 9.6 06/12/2006 22:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 164 0 165 165 9.8 0 9.8 9.6 06/12/2006 22:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 164 0 165 165 9.8 0 9.8 9.6 06/12/2006 22:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 164 0 165 165 9.8 0 9.8 9.6 06/12/2006 22:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 164 0 165 165 9.8 0 10.3 9.6 06/12/2006 22:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 164 0 165 165 9.7 0 10.3 9.3 06/12/2006 22:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 164 0 165 165 9.5 0.2 9.8 9 06/12/2006 23:00:00 0.7 0.4 1.5 0.4 0.4 0.1 1.1 0.4 1 0.5 1.9 0.4 161 24 164 165 9.3 0 9.6 8.8 06/12/2006 23:10:00 1.6 0.2 1.9 1.1 1.4 0.4 1.9 0.4 1.8 0.2 2.3 1.5 343 3 346 165 9.2 0 9.3 8.8 06/12/2006 23:20:00 2.3 0.5 3.4 1.5 1.9 0.8 3.4 0.4 2.4 0.4 3.4 1.9 347 4 341 165 9.4 0.2 9.6 8.8 06/12/2006 23:30:00 2.8 0.3 3.8 1.9 2.3 0.6 3.8 0.4 3 0.3 3.8 2.3 348 5 342 165 9.6 0.1 9.6 9 06/12/2006 23:40:00 2.7 0.2 3.4 2.3 1.5 0.5 3 0.4 3 0.2 3.4 2.6 357 4 351 165 9.6 0.1 9.6 9 06/12/2006 23:50:00 3 0.3 3.4 2.3 1.6 0.4 2.6 0.7 3.2 0.2 3.8 2.6 357 2 356 165 9.5 0.1 9.6 9 06/13/2006 00:00:00 2.8 0.3 3.4 2.3 1.4 0.4 2.6 0.7 3.2 0.2 3.8 2.6 3 5 357 165 9.6 0.1 10.1 9 06/13/2006 00:10:00 2.5 0.2 3.4 1.9 1.3 0.4 2.6 0.4 2.8 0.2 3.4 2.3 2 5 16 165 9.4 0 9.6 8.8 06/13/2006 00:20:00 2.1 0.3 2.6 1.5 1 0.4 1.9 0.4 2.4 0.4 3 1.1 7 5 358 165 9.4 0 9.6 8.8 06/13/2006 00:30:00 2.4 0.3 3 1.9 1.3 0.4 2.6 0.4 2.4 0.3 3 1.5 1 7 13 165 9 0 9.3 8.8 06/13/2006 00:40:00 2.8 0.5 4.2 1.9 2.1 0.9 3.8 0.4 2.7 0.4 4.2 1.9 9 13 31 165 8.8 0 9 8.8 06/13/2006 00:50:00 3.7 0.4 4.9 2.6 3.7 0.4 4.6 2.6 3.4 0.5 4.2 1.9 26 5 23 165 8.9 0 9 8.8 06/13/2006 01:00:00 4 0.3 4.9 3 4 0.3 4.9 3 4 0.4 4.9 3 30 3 32 165 8.9 0 9 8.8 06/13/2006 01:10:00 3.2 0.4 4.2 2.6 3.3 0.4 4.2 2.6 3.6 0.3 4.6 3 29 2 26 165 8.9 0 9 8.8 06/13/2006 01:20:00 3.7 0.4 4.6 3 3.6 0.4 4.6 2.6 3.6 0.4 4.2 2.6 20 3 20 165 8.8 0 9 8.8 06/13/2006 01:30:00 3.7 0.4 4.6 2.6 3.7 0.5 4.6 2.3 3.6 0.4 4.6 2.3 21 6 18 165 8.6 0 8.8 8.5 06/13/2006 01:40:00 4 0.3 4.6 3.4 4.2 0.3 4.9 3.4 4.3 0.3 4.9 3.4 29 2 29 165 8.5 0 9 8.3 06/13/2006 01:50:00 4 0.4 4.9 2.6 3.9 0.5 4.9 2.3 4.1 0.5 4.9 2.6 21 6 23 165 8.5 0 9 8.3 06/13/2006 02:00:00 4.3 0.4 4.9 2.6 4.3 0.4 4.9 2.3 4.4 0.4 5.3 3 22 4 18 165 8.3 0 8.8 8 06/13/2006 02:10:00 3.3 0.4 4.6 2.3 3.4 0.4 4.2 1.9 3.4 0.5 4.6 2.3 25 5 15 165 8.3 0 8.8 7.8 06/13/2006 02:20:00 4.3 0.4 4.9 3.4 4.3 0.4 5.3 3 4.2 0.5 5.3 2.6 23 4 15 165 8.2 0 8.5 7.8 06/13/2006 02:30:00 4.9 0.3 5.7 3.8 4.8 0.3 5.7 3.8 5.1 0.4 6.1 3.8 20 2 21 165 8.2 0 8.8 7.8 06/13/2006 02:40:00 5.8 0.4 6.5 4.9 5.6 0.5 6.5 3.8 5.7 0.5 6.8 4.2 21 3 26 165 8.1 0 8.3 7.8 06/13/2006 02:50:00 6.1 0.3 6.8 5.3 5.7 0.4 6.5 4.6 6.1 0.3 6.8 4.9 21 2 20 165 8.1 0 8.3 7.8 06/13/2006 03:00:00 5.7 0.3 6.5 4.9 5.5 0.4 6.5 4.6 5.8 0.4 6.8 4.2 23 2 26 165 8.1 0 8.3 7.8 06/13/2006 03:10:00 5.2 0.2 5.7 4.6 5 0.4 5.7 3.4 5.4 0.3 6.1 4.2 23 3 24 165 8 0 8.3 7.5 06/13/2006 03:20:00 5.5 0.3 6.1 4.9 5.3 0.4 6.1 4.2 5.7 0.3 6.5 4.9 23 2 16 165 8 0.1 8.3 7.5 06/13/2006 03:30:00 5.6 0.3 6.5 4.9 5.4 0.4 6.5 4.2 5.8 0.4 6.8 4.6 22 3 23 165 8 0.1 8.3 7.5 06/13/2006 03:40:00 5.5 0.3 6.1 4.2 5.4 0.3 6.5 4.2 5.7 0.4 6.5 4.2 24 2 29 165 8 0.1 8.5 7.5 06/13/2006 03:50:00 5.1 0.3 6.1 3.8 4.8 0.5 6.1 3.4 5.3 0.4 6.1 3.8 21 3 32 165 8 0.1 8.3 7.5 06/13/2006 04:00:00 5.2 0.2 5.7 4.6 4.6 0.4 5.7 3.4 5.4 0.3 6.1 4.6 17 2 21 165 8 0 8.3 7.8 06/13/2006 04:10:00 5.1 0.3 5.7 4.6 3.5 0.8 5.3 1.9 5.5 0.3 6.1 4.9 9 4 19 165 8 0 8 7.8 06/13/2006 04:20:00 4.9 0.3 5.7 4.2 3.9 0.8 5.3 1.9 5.2 0.3 5.7 4.2 13 3 16 165 8 0 8 7.8 06/13/2006 04:30:00 5.2 0.3 6.1 4.2 4.7 0.5 6.1 3 5.3 0.4 6.1 4.2 16 3 23 165 8 0 8 7.8 06/13/2006 04:40:00 5 0.4 6.1 3.4 4.2 0.8 5.7 2.3 5 0.4 6.1 3.8 13 5 20 165 8 0 8 7.8 06/13/2006 04:50:00 5.3 0.6 6.5 3.8 4.9 0.6 6.1 2.6 5.3 0.6 7.2 3.8 16 5 15 165 7.9 0 8 7.8 06/13/2006 05:00:00 5.1 0.7 6.5 3 4.9 0.7 6.1 3 5 0.8 6.8 2.6 22 5 20 165 7.9 0 8 7.8 06/13/2006 05:10:00 5.8 0.4 6.8 4.2 5.7 0.5 6.8 3.8 5.8 0.5 6.8 4.2 22 3 18 165 7.8 0 8.3 7.8 06/13/2006 05:20:00 5.3 0.5 6.5 3.8 5 0.6 6.1 3 5.2 0.5 6.5 3.8 19 5 24 165 7.8 0 8 7.8 06/13/2006 05:30:00 4.2 0.5 5.3 2.6 4.1 0.5 5.3 2.3 4.2 0.5 5.3 3 23 6 16 165 7.8 0 7.8 7.8 06/13/2006 05:40:00 3.5 0.8 4.9 1.5 3.6 0.8 4.9 1.1 3.8 0.7 5.3 1.9 30 7 13 165 7.8 0 7.8 7.8 06/13/2006 05:50:00 2.6 0.5 3.4 1.5 2.7 0.5 3.8 1.5 2.9 0.5 3.8 1.9 30 8 31 165 7.8 0 7.8 7.5 06/13/2006 06:00:00 2.3 0.5 3.4 1.1 2.5 0.6 3.8 1.1 2.6 0.5 3.8 1.1 55 11 51 165 7.8 0 7.8 7.5 06/13/2006 06:10:00 2 0.5 3.4 0.7 2.1 0.5 3.4 0.7 2.3 0.4 3.4 1.1 47 11 52 165 7.7 0 7.8 7 06/13/2006 06:20:00 1.5 0.5 2.6 0.4 1.6 0.5 2.6 0.4 1.8 0.4 2.6 0.4 81 32 39 165 7.6 0 7.8 7 06/13/2006 06:30:00 2.1 0.4 3.4 1.1 2.3 0.4 3.4 1.1 2.4 0.4 3.4 1.1 124 8 128 165 7.4 0.1 7.5 6.7 06/13/2006 06:40:00 2.7 0.4 3.4 1.5 2.9 0.4 3.8 1.5 3 0.4 3.8 1.5 128 7 121 165 7.2 0 7.3 6.7 06/13/2006 06:50:00 2.9 0.5 3.8 1.5 3.1 0.5 4.2 1.9 3.2 0.5 4.2 1.9 131 5 129 165 7.1 0 7.3 6.7 06/13/2006 07:00:00 1.8 0.5 2.6 0.4 2 0.5 3 0.4 2.2 0.4 3 1.5 119 7 121 165 7.1 0 7.3 7 06/13/2006 07:10:00 1 0.5 2.3 0.4 1.2 0.5 2.3 0.4 1.8 0.4 2.6 0.7 120 6 117 165 7.3 0 7.5 6.7 06/13/2006 07:20:00 0.4 0.1 0.7 0.4 0.4 0.1 1.1 0.4 0.7 0.4 1.5 0.4 114 5 113 165 7.3 0.1 7.5 6.7 06/13/2006 07:30:00 0.7 0.4 2.3 0.4 0.7 0.5 2.3 0.4 1.1 0.5 2.3 0.4 123 10 116 165 7.4 0 7.5 7 06/13/2006 07:40:00 2.5 0.6 3.8 0.7 2.6 0.6 4.2 1.1 2.7 0.6 4.2 0.7 128 10 117 165 7.3 0 7.5 6.7 06/13/2006 07:50:00 3.9 0.6 5.3 2.3 4 0.6 5.7 2.6 3.9 0.5 4.9 2.6 123 6 126 165 7.2 0 7.3 6.5 06/13/2006 08:00:00 3.8 0.8 5.7 1.9 3.9 0.8 5.7 2.3 3.8 0.7 5.3 2.3 109 9 107 165 7.2 0 7.5 6.7 06/13/2006 08:10:00 3.9 0.6 5.3 1.9 4.1 0.6 5.3 2.3 3.9 0.6 5.7 2.6 110 6 119 165 7.1 0 7.3 6.7 06/13/2006 08:20:00 4.1 0.6 6.1 2.6 4.3 0.6 6.5 2.6 4.1 0.6 5.3 2.6 102 9 104 165 7.2 0 7.3 6.5 06/13/2006 08:30:00 4.4 0.7 6.5 2.3 4.7 0.7 6.8 2.6 4.4 0.6 6.5 3 102 6 97 165 7.2 0 7.5 7.3 06/13/2006 08:40:00 4.9 0.7 6.5 3 5.2 0.7 7.2 3.4 5 0.7 6.8 3 102 9 110 165 7.1 0 7.3 7 06/13/2006 08:50:00 3.7 0.8 5.7 1.9 4.1 0.8 6.1 2.3 3.8 0.7 6.1 2.3 88 13 84 165 7.3 0.1 7.5 7 06/13/2006 09:00:00 2.8 0.6 4.2 1.1 3.2 0.6 4.6 1.5 3 0.6 4.6 1.1 89 17 77 165 7.7 0 8 7.5 06/13/2006 09:10:00 3.2 0.6 4.6 1.5 3.6 0.6 4.6 1.9 3.4 0.5 4.9 1.9 96 10 92 165 7.5 0 7.8 7.5 06/13/2006 09:20:00 3.6 0.8 6.1 1.9 3.9 0.8 6.5 2.3 3.8 0.7 6.1 1.9 99 12 92 165 7.4 0 7.5 7.5 06/13/2006 09:30:00 4.7 0.7 6.8 3 4.9 0.7 6.8 2.6 4.7 0.6 6.5 3.4 97 8 110 165 7.3 0 7.5 7.3 06/13/2006 09:40:00 5.5 0.7 7.6 3.4 5.7 0.7 8 3.8 5.4 0.7 7.2 3.8 90 9 81 165 7.1 0.1 7.5 7 06/13/2006 09:50:00 4 0.7 6.1 2.6 4.3 0.7 6.1 2.6 4.2 0.7 6.1 2.3 82 11 94 165 7.4 0.2 7.8 7 06/13/2006 10:00:00 3.3 0.7 6.1 1.9 3.4 0.7 6.1 1.9 3.4 0.8 6.1 1.9 75 17 93 165 8 0 8.3 7.8 06/13/2006 10:10:00 3.4 0.8 5.7 1.1 3.5 0.8 5.7 1.5 3.5 0.8 5.3 1.5 81 20 79 165 8.2 0 8.5 8 06/13/2006 10:20:00 3.6 0.8 6.1 1.9 3.7 0.8 6.1 1.9 3.7 0.8 6.5 1.9 83 17 58 165 8 0.1 8.3 7.8 06/13/2006 10:30:00 3.3 0.7 4.9 1.5 3.3 0.8 5.3 1.5 3.4 0.8 5.3 1.9 85 19 96 165 8 0 8.3 7.8 06/13/2006 10:40:00 3.6 0.6 5.7 1.9 3.7 0.7 6.1 2.3 3.8 0.7 5.7 2.3 101 11 98 165 8 0 8.3 7.8 06/13/2006 10:50:00 3 0.6 4.6 1.9 3.2 0.6 4.9 1.9 3.2 0.7 5.3 1.5 105 9 112 165 8 0.1 8.3 7.5 06/13/2006 11:00:00 2.5 0.5 3.8 1.1 2.7 0.5 4.2 1.1 2.8 0.5 4.2 1.9 106 10 106 165 8.2 0 8.5 7.8 06/13/2006 11:10:00 2 0.7 3.8 0.4 2.1 0.7 3.4 0.4 2.3 0.6 3.8 0.4 85 23 118 165 8.1 0 8.3 7.8 06/13/2006 11:20:00 2.9 0.5 4.2 1.5 3.1 0.6 4.2 1.5 3.1 0.6 4.9 1.5 110 8 115 165 8.3 0 8.5 8 06/13/2006 11:30:00 1.3 0.6 2.6 0.4 1.3 0.6 2.6 0.4 1.6 0.6 3 0.4 96 20 118 165 8.3 0.2 9 7.5 06/13/2006 11:40:00 2 1 4.2 0.4 1.9 1 4.2 0.4 1.9 0.9 4.2 0.4 52 22 42 165 8 0.2 8.5 7.5 06/13/2006 11:50:00 3 0.9 4.9 0.4 3 0.9 4.6 0.4 3 0.8 4.6 0.4 48 22 41 165 8.1 0.2 8.5 7.5 06/13/2006 12:00:00 3.6 0.5 4.6 2.3 3.5 0.5 4.6 1.9 3.7 0.6 4.6 1.9 35 11 36 165 7.9 0.3 8.3 7.3 06/13/2006 12:10:00 4.6 0.5 6.1 3 4.4 0.6 5.7 2.6 4.6 0.6 6.1 3 24 9 14 165 7.8 0 8 7 06/13/2006 12:20:00 4.6 0.6 5.7 2.6 4.3 0.8 5.7 1.9 4.8 0.6 6.1 3 23 8 29 165 7.9 0.1 8.3 7.5 06/13/2006 12:30:00 5.8 0.9 7.6 3.8 5.6 1 7.6 2.6 5.8 0.9 8 3.8 25 8 27 165 8 0 8 7.5 06/13/2006 12:40:00 5.7 0.8 7.6 3.4 5.6 0.8 7.6 3.8 5.6 0.9 8 3.8 26 7 23 165 7.8 0 8 7.5 06/13/2006 12:50:00 6.5 0.9 8.8 3.8 6.3 1 8.8 3.4 6.5 1 8.8 3.8 21 8 29 165 8 0.1 8.3 7.5 06/13/2006 13:00:00 6.4 0.9 8.8 4.2 5.9 1 8 2.6 6.3 1 9.1 3.8 18 8 14 165 8.1 0 8.3 7.8 06/13/2006 13:10:00 6.7 0.9 9.1 3.8 6.5 1 8.8 3.8 6.6 1 8.8 3.8 22 7 19 165 8 0 8.3 8 06/13/2006 13:20:00 7.2 0.9 9.5 4.6 7 1 9.5 4.2 7 1 9.1 4.2 25 9 36 165 8 0 8.5 7.8 06/13/2006 13:30:00 7.9 1 9.9 4.6 7.5 1.1 9.5 4.2 7.5 1 9.9 4.9 22 9 15 165 8 0 8.3 7.8 06/13/2006 13:40:00 5.9 1.3 9.1 2.3 5.7 1.2 8.8 2.6 5.7 1.3 8.4 2.3 30 14 22 165 7.9 0 8 7.8 06/13/2006 13:50:00 4.6 1 7.2 2.3 4.7 1 7.2 2.6 4.4 0.9 6.8 2.3 42 11 50 165 8 0 8 7.8 06/13/2006 14:00:00 4.6 1.1 7.6 2.3 4.7 1 7.2 2.6 4.6 1 7.6 2.6 32 13 25 165 7.9 0 8 7.8 06/13/2006 14:10:00 6.2 1.1 8.8 3.4 6 1.2 8.4 3 5.9 1.1 8.4 2.6 22 10 19 165 8 0 8.3 7.8 06/13/2006 14:20:00 7.3 0.9 9.9 4.6 7 1 9.5 4.2 7.1 1 10.3 4.2 22 8 14 165 7.9 0 8 7.8 06/13/2006 14:30:00 7.2 0.9 9.1 4.6 7 1 8.8 3.8 7 0.9 8.8 4.2 24 7 23 165 8 0 8 7.8 06/13/2006 14:40:00 6.9 1 9.1 4.2 6.7 1 8.8 4.6 7 1 9.5 4.6 25 7 20 165 8.1 0 8.5 8 06/13/2006 14:50:00 6.9 1 8.8 4.2 6.7 1 8.8 4.2 6.7 1 9.1 4.6 24 7 26 165 8.2 0 8.5 8 06/13/2006 15:00:00 7.5 0.9 10.3 4.6 7.3 1 9.5 4.6 7.4 1 9.5 4.9 23 7 21 165 8.2 0 8.5 8 06/13/2006 15:10:00 8.1 0.8 9.5 5.7 7.8 1 9.9 4.6 8 0.9 9.5 5.3 22 6 29 165 8.1 0 8.3 8 06/13/2006 15:20:00 8.4 0.8 10.3 6.5 8.1 1 10.3 4.9 8.2 1 10.3 5.7 21 6 31 165 8 0 8.3 7.8 06/13/2006 15:30:00 8.3 0.8 9.9 6.5 8 0.9 9.9 5.7 8.2 0.8 9.9 6.1 22 6 29 165 8.1 0 8.3 7.5 06/13/2006 15:40:00 8 1 9.9 5.3 7.5 1.1 9.5 4.9 7.8 1 10.3 5.3 21 6 23 165 8 0 8.5 7.8 06/13/2006 15:50:00 8.4 1.1 10.3 5.3 8.1 1.2 10.7 4.9 8.3 1.1 10.7 5.7 21 6 28 165 8.2 0 8.5 7.8 06/13/2006 16:00:00 7.7 0.8 9.9 5.3 7.3 1 9.5 4.2 7.6 0.9 9.9 5.3 21 6 28 165 8.2 0 8.5 7.8 06/13/2006 16:10:00 7.8 1 9.5 5.3 7.4 1 9.9 4.9 7.8 1 9.9 5.3 19 7 19 165 8.1 0 8.3 7.8 06/13/2006 16:20:00 8.2 1 11.5 5.7 7.7 1.1 10.3 4.6 8 0.8 10.3 6.1 20 7 34 165 8.1 0 8.3 7.5 06/13/2006 16:30:00 8.3 0.9 10.3 6.1 8 1 10.3 5.7 8 1 11.1 5.3 22 6 23 165 8.1 0 8.3 7.8 06/13/2006 16:40:00 8.2 1.1 10.7 5.3 7.8 1.3 11.1 4.2 8 1.1 10.7 5.3 22 8 28 165 8.1 0 8.3 7.8 06/13/2006 16:50:00 8 1 10.3 5.3 7.5 1.2 10.3 3.8 7.7 1.1 11.1 4.9 21 8 18 165 8.2 0 8.3 7.8 06/13/2006 17:00:00 7.7 1 10.7 5.3 7.4 1.1 9.9 4.6 7.7 1.1 10.3 4.9 20 8 6 165 8.2 0 8.5 7.8 06/13/2006 17:10:00 7.9 1.1 11.1 4.6 7.5 1.2 11.1 4.2 7.8 1 10.3 4.6 21 8 29 165 8.1 0 8.3 7.8 06/13/2006 17:20:00 7 1 9.5 4.6 6.7 1 9.9 4.2 6.9 1.2 9.9 4.2 23 9 14 165 8.2 0 8.3 7.8 06/13/2006 17:30:00 8.5 1.1 11.5 4.9 8 1.2 11.1 4.6 8.4 1.2 11.8 4.9 20 8 10 165 8.2 0 8.5 7.8 06/13/2006 17:40:00 8.4 1.1 11.1 5.7 7.9 1.2 11.1 4.9 8.3 1.1 11.1 5.3 19 7 22 165 8.3 0 8.5 8.3 06/13/2006 17:50:00 9 1.1 11.8 5.7 8.5 1.4 11.5 4.2 8.5 1.1 11.1 5.3 18 8 23 165 8.2 0 8.3 8.3 06/13/2006 18:00:00 7.8 1.1 9.9 4.9 7.1 1.2 9.5 3.8 7.7 1.1 10.3 4.9 16 8 14 165 8.2 0 8.5 8.3 06/13/2006 18:10:00 8.5 1.3 11.1 5.7 8.1 1.4 11.5 4.9 8.3 1.3 11.8 4.9 19 8 19 165 8.1 0 8.3 8 06/13/2006 18:20:00 8 1 10.3 5.3 7.3 1.2 9.9 4.2 7.9 1 9.9 5.3 16 8 25 165 8.1 0 8.3 8 06/13/2006 18:30:00 8.7 1.2 12.2 5.3 7.8 1.5 11.5 4.2 8.6 1.2 11.5 5.7 15 8 15 165 8.1 0 8.3 8 06/13/2006 18:40:00 9.6 0.9 11.8 6.1 8.1 1.3 11.1 4.9 9.5 1.2 12.6 6.1 12 7 9 165 8.1 0 8.3 8 06/13/2006 18:50:00 9.2 1 11.8 6.5 7.9 1.3 11.1 4.6 9 1 11.8 6.1 13 7 22 165 8.1 0 8.3 8 06/13/2006 19:00:00 9.1 1.1 11.5 6.1 7.5 1.2 10.3 4.2 9 1.1 11.8 6.1 11 6 7 165 8.2 0 8.3 8 06/13/2006 19:10:00 8.9 1 11.1 6.1 7.9 1.3 10.7 4.9 8.7 1 11.1 6.1 14 6 17 165 8.2 0 8.3 8 06/13/2006 19:20:00 8.7 1.2 11.8 5.7 7.4 1.2 10.7 4.6 8.6 1.2 12.2 5.7 11 8 12 165 8.3 0 8.5 8.3 06/13/2006 19:30:00 9.2 1.1 11.8 5.7 8 1.3 11.1 4.2 8.8 1.1 11.5 6.1 13 7 26 165 8.3 0 8.5 8.3 06/13/2006 19:40:00 9.8 1 12.6 7.2 8.4 1.3 11.5 4.9 9.6 1.2 13.3 6.8 13 7 20 165 8.3 0 8.5 8.3 06/13/2006 19:50:00 10.3 1.1 13.3 7.6 8.5 1.3 11.8 5.3 10.2 1.2 13 6.8 12 6 12 165 8.3 0 8.5 7.8 06/13/2006 20:00:00 10.5 1.1 13.3 8 8.6 1.4 12.2 5.3 10.4 1.1 13.7 7.6 12 6 19 165 8.3 0 8.5 7.8 06/13/2006 20:10:00 10.5 1 13 7.6 8.7 1.4 11.8 4.6 10.1 1.3 13.3 6.8 11 6 11 165 8.3 0 8.5 7.8 06/13/2006 20:20:00 10.1 1.3 14.1 6.8 8.8 1.7 13.7 4.6 10 1.2 13.7 6.8 13 7 16 165 8.3 0 8.5 7.8 06/13/2006 20:30:00 11.2 1.1 13.7 8.4 9.8 1.5 13 5.7 10.9 1.3 13.7 7.6 14 6 19 165 8.3 0 8.5 7.8 06/13/2006 20:40:00 10.3 1 12.6 6.8 8.9 1.5 12.2 4.9 10 1.1 13 6.5 13 6 23 165 8.3 0 8.5 7.8 06/13/2006 20:50:00 10.5 1 12.6 7.6 9 1.5 12.2 5.7 10.1 1.1 13 7.2 13 6 21 165 8.3 0 8.5 7.8 06/13/2006 21:00:00 11.2 1.1 13.3 8 9.8 1.7 13.3 5.7 11.1 1.3 14.1 8 14 6 14 165 8.3 0 8.5 7.8 06/13/2006 21:10:00 10.2 1 12.6 7.2 9 1.3 12.2 5.7 9.9 1.1 12.6 7.2 15 6 14 165 8.3 0 8.5 7.8 06/13/2006 21:20:00 9.6 1 12.2 7.2 8.1 1.3 11.5 4.6 9.4 1 12.2 6.8 12 6 15 165 8.3 0 8.5 7.8 06/13/2006 21:30:00 10.7 1.1 13.7 8 9.4 1.7 13.7 5.3 10.4 1.3 13.7 7.2 13 6 18 165 8.3 0 8.5 8 06/13/2006 21:40:00 10.1 1.2 13 7.2 9 1.6 12.6 5.3 10 1.2 12.6 6.5 14 7 22 165 8.3 0 8.5 7.8 06/13/2006 21:50:00 10.2 1.1 12.2 7.2 9.4 1.3 12.2 5.3 9.8 1.1 12.2 6.8 17 7 28 165 8.3 0 8.5 7.8 06/13/2006 22:00:00 10.1 1 12.2 7.6 9.3 1.3 11.8 6.1 9.8 1.1 12.6 6.1 16 7 18 165 8.3 0 8.8 7.8 06/13/2006 22:10:00 9.8 1 13.3 7.2 8.8 1.3 12.6 4.9 9.6 1.1 12.2 6.8 16 7 23 165 8.3 0 8.5 8.3 06/13/2006 22:20:00 10.6 1 13.3 7.6 9.5 1.5 13 5.7 10.2 1.1 13 7.2 15 5 23 165 8.3 0 8.5 8.3 06/13/2006 22:30:00 10.2 0.8 12.2 8 8.7 1.2 12.2 6.1 10 0.9 13 7.6 13 6 21 165 8.1 0 8.3 8 06/13/2006 22:40:00 9.8 0.8 11.8 7.6 8.2 1.2 10.7 5.3 9.7 1 11.8 6.8 12 6 16 165 8.1 0 8.3 8 06/13/2006 22:50:00 9.6 0.7 11.5 7.6 7.9 1.1 10.7 4.6 9.4 0.9 11.8 6.8 12 6 11 165 8.1 0 8.3 8 06/13/2006 23:00:00 10.1 0.7 11.8 8 8.1 1.2 11.1 4.9 9.9 0.8 11.8 7.6 11 6 12 165 8.2 0 8.3 8.3 06/13/2006 23:10:00 10 0.9 12.2 7.6 7.8 1.2 10.3 4.6 10 0.9 11.8 7.2 10 5 4 165 8.3 0 8.3 8 06/13/2006 23:20:00 10.1 1 12.6 8 7.9 1.2 10.7 5.3 10.1 1.1 12.6 7.6 11 5 18 165 8.3 0 8.5 8.3 06/13/2006 23:30:00 10.1 0.7 11.8 7.6 7.6 1.1 10.3 4.9 10 0.8 12.2 8 10 6 10 165 8.4 0 8.5 8.3 06/13/2006 23:40:00 10 0.9 12.2 7.6 7.9 1.2 11.1 4.6 9.9 1 12.2 7.2 10 5 12 165 8.4 0 8.5 8.3 06/13/2006 23:50:00 9.8 1.1 12.6 6.8 7.8 1.7 11.8 4.2 9.7 1.2 12.6 6.8 10 6 4 165 8.5 0 8.5 8.3 06/14/2006 00:00:00 9.8 0.8 11.8 7.2 7.5 1.2 10.7 4.9 9.8 0.9 11.8 7.6 9 6 17 165 8.5 0 8.5 8.5 06/14/2006 00:10:00 10.1 1 12.6 7.2 8.1 1.2 11.5 5.3 10.1 1 12.6 7.2 12 5 22 165 8.5 0 8.5 8.5 06/14/2006 00:20:00 10.9 0.9 13.3 8 8.4 1.2 11.5 4.9 10.9 0.9 13 8 10 6 11 165 8.5 0 8.5 7.8 06/14/2006 00:30:00 11.3 1.1 13.3 8 8.5 1.4 11.8 5.3 11.3 1 13.7 8.4 10 5 11 165 8.3 0 8.5 7.8 06/14/2006 00:40:00 9.7 0.8 11.8 7.2 7.8 1.2 11.1 5.3 9.6 1 12.2 7.2 12 7 16 165 8.3 0 8.5 7.8 06/14/2006 00:50:00 9.8 1.1 12.2 6.5 7.5 1.4 10.7 4.2 9.8 1.2 12.2 6.8 10 6 2 165 8.3 0 8.5 7.8 06/14/2006 01:00:00 9.5 0.8 11.8 7.2 7.1 1.2 11.1 4.6 9.4 0.9 11.8 7.6 10 5 23 165 8.4 0 8.8 7.8 06/14/2006 01:10:00 8.9 0.9 11.1 6.5 7.2 1.3 9.9 3.8 8.8 1 11.1 6.5 12 6 7 165 8.4 0 8.5 7.8 06/14/2006 01:20:00 8.7 0.8 10.3 6.5 7.2 1.2 9.9 4.2 8.7 0.9 11.1 6.5 12 5 19 165 8.4 0 8.5 7.8 06/14/2006 01:30:00 8.3 1 9.9 5.7 7.2 1.3 9.9 3.4 8.3 1 10.7 5.7 15 6 17 165 8.5 0 8.5 7.8 06/14/2006 01:40:00 8.3 1 10.3 4.9 6.6 1.1 9.9 3.4 8.4 1.1 11.5 6.1 12 7 18 165 8.5 0.1 8.5 7.8 06/14/2006 01:50:00 8.4 0.9 10.3 5.7 6.9 1.2 9.9 3.4 8.4 0.8 10.3 6.5 12 6 21 165 8.5 0.1 8.5 7.8 06/14/2006 02:00:00 8.5 1 11.5 5.3 6.9 1.2 9.1 3.4 8.6 1 12.2 6.1 11 7 8 165 8.5 0.1 8.5 8 06/14/2006 02:10:00 9.1 0.8 11.1 7.2 7.1 1.3 9.9 3.8 9.2 0.8 11.5 7.2 10 6 11 165 8.5 0.1 8.5 8 06/14/2006 02:20:00 9.1 0.9 12.2 6.8 7 1.2 9.9 4.6 9.1 1 11.5 6.5 9 6 14 165 8.5 0.1 8.8 8 06/14/2006 02:30:00 8.1 1 10.3 5.7 6.3 1.2 9.1 3.4 8.2 1 10.7 5.7 10 6 10 165 8.5 0.1 8.8 8 06/14/2006 02:40:00 8.8 1.1 11.1 6.5 6.7 1.2 9.5 4.2 8.9 1.1 11.5 6.5 9 5 14 165 8.6 0 8.8 8 06/14/2006 02:50:00 8.5 0.8 10.7 6.1 6.4 1.1 9.1 3.8 8.6 0.9 10.7 6.1 8 6 6 165 8.6 0 8.8 8.5 06/14/2006 03:00:00 8.4 0.9 10.7 6.5 6.4 1.3 9.1 3.4 8.4 0.9 11.5 6.5 8 6 11 165 8.7 0 8.8 8.5 06/14/2006 03:10:00 8.4 0.9 10.7 5.7 6.3 1.2 10.3 3 8.6 0.9 10.7 6.1 9 6 6 165 8.7 0 8.8 8.5 06/14/2006 03:20:00 8.4 0.8 11.1 6.5 6.3 1.2 10.3 4.2 8.4 0.8 11.8 6.5 8 6 8 165 8.7 0 8.8 8.5 06/14/2006 03:30:00 8.2 0.9 10.7 6.1 6.3 1.2 9.9 3.8 8.4 0.9 10.7 6.1 8 6 7 165 8.7 0 8.8 8.5 06/14/2006 03:40:00 8.1 1 10.7 5.7 6.3 1.1 9.1 3.4 8.1 1 11.1 6.1 8 7 14 165 8.8 0 9 8.8 06/14/2006 03:50:00 8.3 1 10.7 6.1 6.3 1.3 10.3 3.4 8.4 1.1 11.1 6.1 8 7 3 165 8.8 0 9 8.8 06/14/2006 04:00:00 8.1 0.7 9.5 5.7 6.8 1.1 9.1 4.2 8.1 0.8 9.9 5.7 12 5 16 165 8.8 0 9 8.8 06/14/2006 04:10:00 7.8 0.6 9.1 5.7 6.4 1.1 8.8 3.8 7.8 0.7 9.9 5.7 11 5 11 165 8.7 0 8.8 8.8 06/14/2006 04:20:00 8 0.6 9.1 6.5 6.5 1 8.8 3.8 8.2 0.6 9.5 6.1 11 5 17 165 8.7 0 8.8 8.5 06/14/2006 04:30:00 8.4 0.8 10.3 5.7 6.5 1.2 9.5 3.8 8.5 0.7 9.9 6.5 10 6 4 165 8.7 0 8.8 8.8 06/14/2006 04:40:00 8.7 0.8 10.3 6.8 6.9 1.2 10.3 3.8 8.8 0.8 10.7 6.5 10 5 21 165 8.8 0 9 8.8 06/14/2006 04:50:00 8.4 0.9 10.3 5.7 6.7 1.2 9.9 4.2 8.3 1 10.7 5.3 10 5 16 165 8.8 0 8.8 8.8 06/14/2006 05:00:00 8.3 0.8 10.3 6.1 6.9 1.1 9.9 4.2 8.3 0.9 10.7 6.1 12 5 6 165 8.7 0 9 8.3 06/14/2006 05:10:00 7.9 0.6 9.5 6.1 6.3 1.1 8.8 3.8 7.8 0.7 9.5 5.7 10 6 6 165 8.8 0 9 8.5 06/14/2006 05:20:00 8.1 0.9 10.3 4.9 6.6 1.3 9.5 3.8 8 0.9 10.7 4.9 10 6 14 165 8.8 0 9 8.5 06/14/2006 05:30:00 7.5 0.7 9.9 5.7 6 1.2 9.5 3.4 7.4 0.8 9.5 5.3 11 7 19 165 8.8 0 9 8.5 06/14/2006 05:40:00 8.1 0.7 9.9 6.1 7 1.2 9.9 4.2 8.1 0.8 10.3 6.5 14 8 20 165 8.9 0 9 8.5 06/14/2006 05:50:00 8.5 0.6 11.1 6.8 7.3 1 9.9 4.2 8.4 0.7 10.7 6.1 13 5 12 165 8.8 0 9 8.5 06/14/2006 06:00:00 8.5 0.8 10.3 5.7 7.4 1.2 9.9 4.6 8.4 0.9 10.3 5.3 13 6 16 165 8.8 0 9 8.3 06/14/2006 06:10:00 7.9 1 9.9 5.7 6.7 1.4 9.5 3.4 7.8 1 9.9 5.3 12 7 7 165 8.8 0 9 8.5 06/14/2006 06:20:00 8.2 0.8 10.3 6.1 6.6 1.3 9.5 3.4 8.2 1 10.7 4.9 10 6 18 165 8.9 0 9 8.5 06/14/2006 06:30:00 8 1 10.7 4.9 6.5 1.5 9.9 3 8.1 1.1 11.1 5.3 10 7 16 165 8.8 0 9 8.5 06/14/2006 06:40:00 8 1 10.3 5.7 6.8 1.6 9.9 3.4 8.1 1 10.3 5.7 13 8 15 165 8.8 0 9 8.5 06/14/2006 06:50:00 7.6 1.1 10.7 4.9 6.1 1.5 9.9 3.4 7.5 1.1 10.3 4.9 8 9 16 165 8.8 0 9 8.5 06/14/2006 07:00:00 7.9 1 10.7 4.9 6 1.5 10.3 3.4 7.9 1 10.7 5.3 8 7 18 165 8.9 0 9 8.5 06/14/2006 07:10:00 8.8 1.1 11.5 6.5 7.1 1.7 11.1 3.4 8.8 1 11.5 6.5 11 6 25 165 8.9 0 9 8.5 06/14/2006 07:20:00 8.1 0.8 10.3 6.5 7 1.1 10.3 3.4 8.2 0.9 10.7 5.7 13 6 18 165 8.9 0 9 8.8 06/14/2006 07:30:00 8.3 1.1 11.1 5.7 6.4 1 9.1 3.8 8.3 1.2 11.1 5.7 9 7 9 165 9 0 9 8.8 06/14/2006 07:40:00 8.7 0.9 11.1 6.1 6.7 1.5 10.7 3.8 8.7 1 10.7 6.1 9 6 16 165 9 0 9 9 06/14/2006 07:50:00 8.1 0.8 9.9 5.3 6.1 1.2 9.5 3.4 8.1 0.9 9.9 5.3 8 6 14 165 9.1 0 9.3 9 06/14/2006 08:00:00 8.4 0.7 9.9 6.8 7 1.3 9.5 3.8 8.3 0.7 10.3 6.5 13 6 6 165 9.1 0 9.3 9 06/14/2006 08:10:00 8.6 0.8 10.7 6.1 7.3 1.2 10.3 4.2 8.5 0.9 10.7 5.7 13 5 15 165 9.1 0 9.3 9 06/14/2006 08:20:00 8.3 0.7 10.7 6.5 7.3 1.1 10.7 4.2 8.3 0.8 9.9 5.7 14 6 22 165 9.2 0 9.3 9 06/14/2006 08:30:00 8.2 0.7 9.9 6.1 6.4 1.1 9.5 4.2 8.4 0.7 10.3 6.5 10 5 18 165 9.3 0 9.8 9 06/14/2006 08:40:00 7.8 0.6 9.9 6.1 7.1 0.8 9.5 4.2 8 0.6 9.9 5.7 16 6 20 165 9.4 0 9.6 9.3 06/14/2006 08:50:00 7.7 0.6 9.1 6.1 6.9 1 8.8 3.8 7.9 0.7 9.5 5.7 14 5 16 165 9.4 0 9.6 9.3 06/14/2006 09:00:00 7.7 0.6 9.9 6.1 6.5 1.1 9.5 4.2 7.8 0.6 9.5 6.1 12 5 32 165 9.4 0 9.6 9.3 06/14/2006 09:10:00 7.9 0.5 9.5 6.5 7.1 0.7 8.8 4.9 8 0.6 9.9 5.7 15 4 19 165 9.4 0 9.8 9.3 06/14/2006 09:20:00 7.1 0.5 8.4 5.3 6.6 0.7 8.4 3.8 7.1 0.6 8.4 5.3 16 4 19 165 9.4 0 9.6 9.3 06/14/2006 09:30:00 7.3 0.5 8.8 5.7 6.8 0.7 8.4 3.8 7.4 0.6 8.8 5.7 17 4 15 165 9.4 0 9.6 9 06/14/2006 09:40:00 7.8 0.5 9.1 6.5 7 0.7 8.4 3.8 7.8 0.6 9.5 5.7 14 4 10 165 9.5 0 9.8 9 06/14/2006 09:50:00 7.4 0.6 9.1 5.7 6.5 1 8.8 3.4 7.6 0.6 9.1 5.7 14 6 22 165 9.6 0.1 10.1 9.3 06/14/2006 10:00:00 7.6 0.5 9.1 6.1 6.8 0.8 8.4 3.8 7.8 0.7 9.1 5.3 14 5 19 165 9.6 0 9.8 9.3 06/14/2006 10:10:00 7.3 0.6 8.8 5.3 6.4 0.8 8 3.8 7.2 0.7 8.8 5.3 13 5 10 165 9.6 0 10.3 9.3 06/14/2006 10:20:00 7.4 0.7 9.1 5.3 6.7 1 9.1 3.4 7.6 0.8 9.1 5.7 15 5 18 165 9.7 0 9.8 9.6 06/14/2006 10:30:00 7.1 0.6 8.8 5.3 6.3 0.9 8.4 3.4 7.2 0.7 9.5 5.3 15 5 21 165 9.6 0 10.3 9.3 06/14/2006 10:40:00 7.3 0.7 9.5 5.3 6.4 1 9.1 3.8 7.3 0.8 9.5 5.3 14 6 28 165 9.6 0 9.8 9.6 06/14/2006 10:50:00 7.2 0.8 9.1 5.3 6.7 1 9.1 3.8 7.3 0.8 9.5 4.9 17 6 22 165 9.6 0 10.3 9.6 06/14/2006 11:00:00 7.1 0.7 9.5 4.9 6.6 1 8.8 3 7 0.8 9.1 4.9 18 7 18 165 9.6 0 9.8 9.6 06/14/2006 11:10:00 7.3 0.7 8.8 4.9 6.9 0.8 8.8 4.2 7.2 0.7 9.1 5.3 19 5 19 165 9.6 0 9.8 9.6 06/14/2006 11:20:00 6.9 0.9 9.1 4.6 6.4 1 9.1 3.4 7 0.9 9.5 4.9 18 7 19 165 9.7 0 9.8 9.3 06/14/2006 11:30:00 7.3 0.8 8.8 4.6 6.9 1 8.4 3 7.3 0.8 8.8 4.9 20 6 16 165 9.6 0 9.8 9.3 06/14/2006 11:40:00 7.1 0.8 8.8 4.6 6.7 0.9 8.8 4.2 7.2 0.8 8.8 5.3 20 6 20 165 9.6 0 9.8 9.3 06/14/2006 11:50:00 6.5 0.8 8.4 3.4 6 0.9 8 2.6 6.7 0.8 8.4 4.6 18 6 16 165 9.7 0 10.3 9.6 06/14/2006 12:00:00 6.9 0.6 8.4 5.3 6.4 0.7 8.4 3.8 7.1 0.6 8.4 4.9 19 5 23 165 9.7 0 9.8 9.6 06/14/2006 12:10:00 6.8 0.7 8.4 4.6 6.4 0.9 8.4 3.4 6.9 0.8 8.8 4.6 19 5 25 165 9.6 0 9.8 9.6 06/14/2006 12:20:00 6.7 0.6 8 4.6 6.1 0.8 8 3 6.7 0.6 8.4 4.9 17 5 26 165 9.6 0 9.8 9.6 06/14/2006 12:30:00 6.8 0.6 8 4.9 6.3 0.8 8 3.4 6.8 0.7 8 4.9 19 5 22 165 9.6 0 9.8 9.6 06/14/2006 12:40:00 7 0.5 8.8 5.3 6.5 0.7 8.4 3.8 6.9 0.6 8.8 5.3 20 6 32 165 9.6 0 10.3 9.6 06/14/2006 12:50:00 6.7 0.8 8.4 4.6 6.3 0.9 8 3.8 6.8 0.9 9.1 4.9 20 6 21 165 9.7 0 10.3 9.6 06/14/2006 13:00:00 7 0.7 8.4 4.9 6.6 1 8.4 3 7 0.8 8.8 4.6 20 5 23 165 9.6 0 9.8 9.6 06/14/2006 13:10:00 6.7 0.6 8.4 4.6 6.2 0.8 8 2.6 6.8 0.6 8.8 5.3 19 6 19 165 9.6 0 9.6 9.6 06/14/2006 13:20:00 6.8 0.7 8.4 4.9 6.5 0.8 8.4 3.4 6.9 0.7 8.8 4.6 21 6 23 165 9.6 0 9.8 9.6 06/14/2006 13:30:00 7 0.8 8.8 4.6 6.6 1 8.8 3 7.1 0.8 8.8 4.9 19 6 24 165 9.6 0 9.6 9.6 06/14/2006 13:40:00 6.7 0.7 8.8 4.6 6.2 0.9 8.8 3.4 6.7 0.7 8.4 4.9 19 6 27 165 9.6 0 9.8 9.6 06/14/2006 13:50:00 6.7 0.7 8.8 4.9 6.4 1 8.4 3 6.9 0.8 8.4 4.9 20 6 20 165 9.6 0 10.1 9.6 06/14/2006 14:00:00 6.2 0.7 8 4.2 5.7 0.9 8 2.3 6.2 0.7 7.6 4.2 18 7 21 165 9.6 0 9.6 9.6 06/14/2006 14:10:00 6.6 0.7 8.8 4.9 6.1 0.9 8.4 3 6.6 0.7 8.4 4.9 17 6 22 165 9.6 0 9.8 9.3 06/14/2006 14:20:00 6.8 0.6 8.4 4.6 5.9 0.9 8 3.4 6.9 0.7 8.8 4.9 14 6 16 165 9.6 0 9.8 9.6 06/14/2006 14:30:00 6.9 0.6 8.4 5.3 5.8 0.9 7.6 3.4 6.9 0.7 8.8 5.3 13 5 9 165 9.8 0 9.8 9.6 06/14/2006 14:40:00 7.2 0.8 9.1 4.9 6.3 1 8.8 3.8 7.1 0.9 9.1 4.6 14 5 14 165 9.9 0 10.1 9.6 06/14/2006 14:50:00 7 0.7 9.1 5.3 5.6 1 8.4 3 7.1 0.7 9.1 4.9 10 6 6 165 10 0 10.3 9.8 06/14/2006 15:00:00 7 0.6 8.4 4.9 5.7 1.1 8 2.6 6.9 0.7 8.4 5.3 11 6 18 165 10.1 0.1 10.3 9.6 06/14/2006 15:10:00 7 0.7 9.1 5.3 5.7 1.1 8.4 3 6.9 0.7 8.8 4.9 11 6 12 165 10.1 0.1 10.3 9.8 06/14/2006 15:20:00 6.4 0.6 8.4 4.6 5.3 1 8 2.6 6.5 0.6 8 4.2 12 7 21 165 10.1 0.2 10.3 9.6 06/14/2006 15:30:00 6.7 0.7 8.4 4.9 5.5 1.2 7.6 3 6.8 0.8 8.8 4.6 11 7 7 165 10.1 0.2 10.6 9.6 06/14/2006 15:40:00 7.1 0.7 8.8 4.9 4.8 0.8 7.2 2.6 7.2 0.7 8.8 4.9 4 5 9 165 10.1 0.2 10.6 9.6 06/14/2006 15:50:00 6.1 0.8 7.6 4.2 5.3 1.1 8 2.6 6 0.7 8 4.2 13 8 21 165 10.1 0.2 10.9 9.6 06/14/2006 16:00:00 6.4 0.6 8 4.6 5.8 1 7.6 2.6 6.4 0.8 8 4.2 16 7 18 165 10 0.2 10.6 9.6 06/14/2006 16:10:00 6.3 0.6 8 3.8 5.9 0.6 7.6 4.2 6.4 0.6 7.6 4.6 18 5 12 165 10 0.1 10.6 9.3 06/14/2006 16:20:00 6.7 0.5 8 4.9 5.8 0.9 7.6 3.4 6.7 0.6 8.4 4.9 14 5 14 165 10 0 10.3 9.3 06/14/2006 16:30:00 6.7 0.7 8.4 4.9 6.2 1 8.4 3.4 6.7 0.8 8.4 4.9 16 4 18 165 10 0 10.3 9.3 06/14/2006 16:40:00 6.2 0.6 7.6 3.8 5.9 0.8 8 3.4 6.1 0.6 8 4.6 19 6 25 165 9.9 0 10.6 9.3 06/14/2006 16:50:00 7.2 0.9 9.1 4.2 7 1 9.1 3 6.9 0.9 9.1 3.8 25 8 28 165 9.7 0 9.8 9.6 06/14/2006 17:00:00 6.9 0.8 8.8 4.6 6.8 0.9 8.8 4.2 6.8 0.8 9.1 4.2 27 7 30 165 9.4 0 9.6 9.3 06/14/2006 17:10:00 7.6 0.7 9.1 4.9 7.5 0.8 9.1 4.6 7.5 0.8 9.1 4.9 25 5 18 165 9.4 0 9.6 9.3 06/14/2006 17:20:00 6.7 0.7 8.4 4.6 6.7 0.7 8.4 4.6 6.5 0.6 8.4 4.9 27 6 28 165 9.4 0 9.3 9.3 06/14/2006 17:30:00 6.6 0.7 8 4.2 6.5 0.7 8.4 4.2 6.4 0.7 8 4.6 27 5 32 165 9.4 0 9.3 9.3 06/14/2006 17:40:00 7.1 0.6 8.4 5.3 7 0.6 8.4 4.9 6.7 0.6 8.4 4.9 27 4 22 165 9.4 0 9.6 9.3 06/14/2006 17:50:00 6.9 0.6 8.4 4.9 6.9 0.7 8.8 4.9 6.6 0.7 8.4 4.9 28 5 24 165 9.4 0 9.6 9.3 06/14/2006 18:00:00 6.7 0.7 8.4 3.8 6.6 0.8 8.4 4.2 6.5 0.7 8.4 4.2 25 6 28 165 9.4 0 9.6 9.3 06/14/2006 18:10:00 7.4 0.6 8.8 5.3 7 0.8 8.4 3.8 7.3 0.7 8.8 5.3 19 5 24 165 9.4 0 9.6 9.3 06/14/2006 18:20:00 7 0.8 8.8 4.6 6.5 1 8.8 3.4 6.9 0.8 8.8 4.6 17 8 26 165 9.4 0 9.6 9.3 06/14/2006 18:30:00 5.9 0.6 7.6 3.8 5.2 0.9 7.6 2.3 5.8 0.6 8 4.2 13 7 7 165 9.6 0 9.8 9.6 06/14/2006 18:40:00 6 0.6 7.6 4.2 5 1 7.2 2.6 6 0.6 7.2 3.8 9 8 358 165 9.8 0 10.3 9.6 06/14/2006 18:50:00 6.7 1 9.1 4.2 5.2 1.1 8.8 2.3 6.4 1 9.1 4.2 7 7 12 165 9.8 0 10.3 9.6 06/14/2006 19:00:00 6.6 0.6 8 5.3 5.1 1 8 2.3 6.4 0.7 8.4 4.6 9 6 16 165 9.8 0 9.8 9.6 06/14/2006 19:10:00 6.5 1 9.1 4.6 5.2 1 9.1 2.6 6.4 0.9 8.8 4.6 6 8 10 165 10 0 10.1 9.6 06/14/2006 19:20:00 8.1 1.3 11.8 5.7 6.6 1.3 11.1 3.8 7.6 1.4 11.1 4.9 7 9 339 165 10 0 10.1 9.6 06/14/2006 19:30:00 8.7 0.9 11.1 6.8 6.4 1.1 10.7 3.8 8.4 1 11.1 6.1 2 7 355 165 10 0 10.6 9.8 06/14/2006 19:40:00 8.7 1.1 11.8 5.3 6.7 1.3 10.7 3.4 8.2 1.2 11.5 5.3 360 8 15 165 10.1 0 10.6 9.8 06/14/2006 19:50:00 8.8 1 11.8 5.7 6.3 1.1 9.9 3.4 8.6 1.1 11.1 5.7 359 6 358 165 10.1 0 10.6 9.8 06/14/2006 20:00:00 8.9 1.3 11.8 6.1 6.6 1.6 11.5 3.4 8.8 1.2 11.8 5.7 358 7 1 165 10.1 0 10.3 9.8 06/14/2006 20:10:00 6.4 0.8 8.4 4.6 4.8 1.2 8.4 2.3 6.2 0.8 9.1 4.2 6 9 2 165 10.1 0 10.9 9.8 06/14/2006 20:20:00 7.6 1.2 11.1 5.3 5.7 1.4 9.5 3 7.3 1.1 9.9 4.6 2 8 1 165 10.1 0 10.3 9.8 06/14/2006 20:30:00 7.8 1 11.1 5.3 6.4 1.5 10.7 3.4 7.3 1 9.9 4.6 356 9 355 165 10.2 0 10.6 10.1 06/14/2006 20:40:00 7.9 1 10.3 5.7 5.9 1.3 9.9 2.6 7.8 1 10.7 5.7 5 8 18 165 10.1 0 10.3 9.8 06/14/2006 20:50:00 8.8 1.2 11.5 6.1 7 1.5 10.7 3.8 8.6 1.3 11.8 4.9 9 7 13 165 10.1 0 10.6 9.8 06/14/2006 21:00:00 8.4 1.1 11.5 5.3 6.7 1.5 10.7 3.4 8.2 1.2 11.5 5.7 7 9 7 165 10.1 0 10.3 10.1 06/14/2006 21:10:00 9 1.2 11.5 5.7 7.1 1.5 10.7 3.4 8.7 1.3 11.8 5.7 8 8 11 165 10.1 0 10.3 10.1 06/14/2006 21:20:00 8.1 0.9 10.7 5.3 5.8 1.1 9.1 3.4 7.9 1 10.7 5.7 4 7 4 165 10.2 0 10.3 10.1 06/14/2006 21:30:00 9.4 1.2 11.8 6.5 7 1.3 11.1 4.2 9.1 1.2 12.2 6.5 3 8 358 165 10.2 0 10.6 10.3 06/14/2006 21:40:00 10.2 1.2 13 7.2 7.7 1.5 11.5 4.9 10.1 1.2 13 6.5 7 7 9 165 10.2 0 10.9 10.3 06/14/2006 21:50:00 9.9 1.1 13 6.8 7.6 1.3 11.8 4.6 9.7 1.2 13.3 6.8 3 8 5 165 10.2 0 10.3 10.3 06/14/2006 22:00:00 9.3 1.1 12.2 6.5 7 1.3 10.7 4.2 9.2 1.1 12.2 6.1 9 6 9 165 10.2 0 10.3 10.1 06/14/2006 22:10:00 9.4 1.1 11.8 6.1 7.2 1.4 11.1 4.6 9.4 1.1 12.2 6.1 8 7 9 165 10.1 0 10.6 10.1 06/14/2006 22:20:00 9.5 1.3 12.6 6.8 6.8 1.4 10.7 3.8 9.4 1.4 12.6 6.5 7 6 3 165 10 0 10.3 9.8 06/14/2006 22:30:00 9.6 0.8 11.5 7.6 6.7 1.2 10.3 4.2 9.4 0.9 11.5 6.8 6 6 360 165 10 0 10.1 9.8 06/14/2006 22:40:00 9.7 0.7 11.5 8 7.1 1.3 10.3 4.6 9.8 0.9 11.8 7.2 8 5 6 165 9.9 0 10.3 9.8 06/14/2006 22:50:00 8.6 1 11.5 6.1 6.9 1.5 11.5 3.4 8.5 1.1 11.1 5.7 11 7 14 165 9.9 0 9.8 9.8 06/14/2006 23:00:00 7.7 1.1 10.7 5.3 6.4 1.2 9.1 3.8 7.7 1.2 11.5 5.3 13 8 12 165 9.8 0 10.3 9.6 06/14/2006 23:10:00 7.3 1 9.5 4.6 6.4 1.3 9.1 3.4 7.1 0.9 9.5 5.3 15 8 6 165 9.7 0 9.8 9.3 06/14/2006 23:20:00 7.5 0.6 9.1 5.7 6.8 1 8.8 4.2 7.4 0.6 8.8 5.7 16 6 14 165 9.6 0 9.8 9.3 06/14/2006 23:30:00 7.9 0.8 9.9 5.7 6.3 1 9.1 4.2 7.9 0.8 10.3 5.3 10 5 16 165 9.6 0 9.6 9.3 06/14/2006 23:40:00 8 0.8 10.3 6.1 7 1.2 10.3 3.8 7.9 0.9 10.7 6.1 14 6 21 165 9.6 0 10.3 9.3 06/14/2006 23:50:00 7.7 0.8 9.5 5.7 7.2 1 9.1 4.6 7.4 0.9 9.5 5.3 18 7 19 165 9.6 0 9.6 9.3 06/15/2006 00:00:00 8.1 0.7 9.9 6.1 7.5 0.9 9.1 4.2 7.7 0.7 9.5 5.3 17 6 18 165 9.6 0 9.6 9.3 06/15/2006 00:10:00 7.8 0.8 9.5 5.3 7.6 0.9 9.1 4.6 7.6 0.9 10.3 5.7 21 6 25 165 9.4 0 9.8 9 06/15/2006 00:20:00 7.6 0.8 9.1 5.3 7.4 0.9 9.1 4.9 7.4 0.9 9.9 4.9 22 6 26 165 9.4 0 9.6 9 06/15/2006 00:30:00 7.2 0.9 9.1 4.9 6.9 1 8.8 4.6 7.1 0.9 9.1 4.9 19 6 16 165 9.4 0 9.8 9 06/15/2006 00:40:00 8.1 1 9.9 5.3 7.6 1.1 9.5 4.9 7.7 1 9.9 4.9 18 6 22 165 9.4 0 9.6 9 06/15/2006 00:50:00 7.8 0.8 9.9 5.7 7.1 1 9.9 4.2 7.7 0.7 9.9 5.7 15 6 16 165 9.4 0 9.6 9 06/15/2006 01:00:00 7.9 0.6 9.5 5.7 6.4 1 8.8 3.4 7.6 0.7 9.1 5.7 11 5 353 165 9.4 0 9.6 9 06/15/2006 01:10:00 8 0.8 9.9 5.3 6.1 1.2 9.1 3 7.8 0.8 9.5 5.3 9 6 4 165 9.5 0 9.8 9 06/15/2006 01:20:00 7.8 0.9 10.3 5.7 5.8 1.4 9.9 3 7.7 0.9 9.9 5.3 7 7 13 165 9.5 0 10.1 9 06/15/2006 01:30:00 8.1 0.8 9.9 6.1 6.1 1.1 9.1 3.4 8.1 0.9 9.9 6.5 9 5 14 165 9.5 0 10.1 9 06/15/2006 01:40:00 8.3 0.8 11.1 6.1 6.5 1.2 9.5 3.8 8.3 0.9 11.5 5.7 10 6 11 165 9.5 0 9.6 9.3 06/15/2006 01:50:00 8.4 1 11.1 6.1 7.4 1.3 10.3 3.8 8.1 1 11.1 5.3 14 7 5 165 9.5 0 9.8 9.3 06/15/2006 02:00:00 8.5 1 10.7 5.7 7.2 1.3 10.7 3.8 8.2 1.1 10.7 5.3 13 8 10 165 9.4 0 9.6 9.3 06/15/2006 02:10:00 8.7 1 10.7 6.5 8.3 1 10.3 5.3 8.3 1.1 11.1 5.7 18 5 10 165 9.2 0 9.3 9 06/15/2006 02:20:00 8.2 0.7 9.5 4.9 7.8 0.9 9.5 4.2 8.1 0.8 9.5 5.7 19 5 16 165 9.1 0 9.3 9 06/15/2006 02:30:00 8.6 0.7 10.3 6.8 8.2 0.9 10.3 4.9 8.3 0.8 10.3 5.7 18 5 25 165 9.1 0 9.3 9 06/15/2006 02:40:00 8.4 0.9 10.7 6.1 7.8 1.2 10.7 4.2 8.2 1 10.7 5.7 16 6 16 165 9.1 0 9.3 9 06/15/2006 02:50:00 8.4 0.8 10.3 6.1 7 1.3 9.9 4.2 8.1 0.9 10.3 5.7 11 7 19 165 9.1 0 9.6 9 06/15/2006 03:00:00 8.1 0.9 10.7 5.3 6.5 1.1 10.3 3.8 8 0.9 11.1 5.7 10 6 18 165 9.2 0 9.6 9 06/15/2006 03:10:00 8.4 0.8 11.1 6.1 7.4 1.2 11.1 4.2 8.2 0.8 10.7 6.1 14 7 22 165 9.3 0 9.3 9 06/15/2006 03:20:00 8.5 0.8 10.3 6.5 7.1 1.1 9.5 4.6 8.3 0.9 10.3 5.7 10 7 11 165 9.2 0 9.3 9 06/15/2006 03:30:00 9.1 0.8 11.1 7.2 6.5 1.1 9.1 4.2 9.1 0.9 11.1 6.8 6 6 5 165 9.2 0 9.3 9 06/15/2006 03:40:00 7.6 0.9 9.5 5.3 5.5 1 8.8 3.4 7.4 0.9 9.9 5.3 5 7 14 165 9.3 0 9.6 9 06/15/2006 03:50:00 8.5 1 11.5 5.7 6.4 1.3 10.3 3.8 8.3 1.1 11.1 5.3 6 7 11 165 9.4 0 9.6 9 06/15/2006 04:00:00 8 1 10.7 5.7 6.2 1.2 9.1 3.4 8 1 10.7 5.3 9 7 8 165 9.4 0 9.6 9 06/15/2006 04:10:00 8 0.7 9.5 6.1 5.6 1 8.4 3.8 7.9 0.7 9.5 6.1 4 6 358 165 9.5 0 9.6 9 06/15/2006 04:20:00 7.1 0.9 9.5 4.6 5.6 1.3 8.8 3 6.8 0.9 9.5 4.6 5 10 19 165 9.5 0 9.6 9 06/15/2006 04:30:00 7 1 9.9 4.6 5.4 1.1 9.1 2.6 6.7 1 9.5 4.6 5 10 358 165 9.6 0 10.1 9 06/15/2006 04:40:00 7.5 1.2 10.7 4.6 5.6 1.2 9.1 2.6 7.3 1.2 9.9 3.4 2 8 351 165 9.5 0 9.6 9 06/15/2006 04:50:00 7.9 1.1 10.7 5.3 6 1.1 9.1 3.4 7.8 1.1 10.7 5.3 5 7 356 165 9.5 0 9.6 9 06/15/2006 05:00:00 8.2 1 11.1 5.7 6.1 1.4 10.3 3.4 8 1.1 11.5 5.3 4 7 15 165 9.5 0 9.8 9.3 06/15/2006 05:10:00 7.4 0.8 9.5 4.6 5.9 1.2 9.1 3.4 7.3 0.9 10.7 5.7 4 10 15 165 9.5 0 9.6 9 06/15/2006 05:20:00 8.5 1.1 12.2 5.7 6.7 1.5 10.7 3.4 8.2 1 11.1 5.7 358 9 357 165 9.6 0 9.6 9 06/15/2006 05:30:00 8.6 1.2 11.5 5.7 6.2 1.2 9.9 3.4 8.6 1.3 11.5 5.3 0 7 359 165 9.6 0.1 9.6 9.3 06/15/2006 05:40:00 7.5 1 10.3 4.6 6.6 1.4 10.3 3.4 7.5 1 9.9 4.9 14 8 32 165 9.6 0.1 9.6 9 06/15/2006 05:50:00 8.5 1 10.7 5.7 7 1.3 9.9 3.8 8.5 0.9 10.7 5.7 11 6 7 165 9.6 0 9.6 9 06/15/2006 06:00:00 8.5 1 11.1 5.7 7.1 1.4 10.7 3.4 8.5 1.1 11.1 5.7 11 7 17 165 9.6 0 9.8 9 06/15/2006 06:10:00 8 1 10.7 5.7 6.6 1.5 11.1 3.4 8 0.9 10.7 5.7 12 8 36 165 9.6 0 9.6 9.6 06/15/2006 06:20:00 8 0.9 10.7 6.1 6.5 1.7 10.3 3.4 7.8 0.9 10.7 5.7 12 9 27 165 9.6 0 9.6 9.6 06/15/2006 06:30:00 7.8 0.6 9.9 5.7 6.3 1 9.5 3.4 7.8 0.7 9.5 6.1 11 7 21 165 9.5 0 9.8 9.3 06/15/2006 06:40:00 8.1 1 10.3 5.7 6.8 1.4 9.9 3.8 8.2 1 10.7 5.3 12 8 12 165 9.5 0 10.1 9.3 06/15/2006 06:50:00 8.2 0.9 10.7 6.1 6.5 1.5 10.7 3.4 7.9 1 10.7 5.7 10 7 19 165 9.5 0 10.1 9.3 06/15/2006 07:00:00 8.3 1 11.5 6.1 6.5 1.6 11.5 3.4 8.1 1.1 11.5 5.3 9 7 26 165 9.6 0 9.6 9.3 06/15/2006 07:10:00 8.1 1 10.3 4.2 6.5 1.3 9.5 3.4 8 0.9 9.9 4.2 11 8 6 165 9.6 0 9.8 9.6 06/15/2006 07:20:00 7.9 0.8 9.9 6.1 6.1 1.3 9.9 3 7.7 0.8 9.5 5.7 9 8 28 165 9.6 0 9.6 9.6 06/15/2006 07:30:00 8.4 0.9 10.3 6.1 6.3 1.2 9.5 3.8 8.3 0.9 10.3 6.1 7 6 10 165 9.6 0 9.8 9.6 06/15/2006 07:40:00 8.3 0.9 11.5 6.1 7.3 1 9.5 4.6 8.2 1 11.5 5.3 14 7 5 165 9.6 0 9.8 9.6 06/15/2006 07:50:00 8.6 0.8 10.7 6.1 6.9 1 10.3 4.6 8.4 1 11.1 5.3 10 6 11 165 9.6 0 10.1 9.6 06/15/2006 08:00:00 9 0.8 11.5 6.5 7.5 1.3 10.7 4.6 8.9 1 10.7 6.1 11 6 18 165 9.6 0 9.6 9.6 06/15/2006 08:10:00 8.2 0.7 9.9 6.1 7.1 1.2 9.9 3.8 8 1 10.3 5.3 13 6 16 165 9.6 0 9.6 9.6 06/15/2006 08:20:00 9.3 0.7 11.1 6.8 8.7 1 10.7 5.3 9 0.9 10.7 6.1 16 4 28 165 9.6 0 9.6 9.3 06/15/2006 08:30:00 9 0.6 10.3 7.2 8.3 0.8 10.3 5.3 8.8 0.8 11.1 6.8 15 3 16 165 9.6 0 9.6 9.3 06/15/2006 08:40:00 8.2 0.7 10.7 6.5 6.7 1.2 10.3 3.4 8.2 0.7 9.9 6.1 11 6 21 165 9.6 0 9.8 9.3 06/15/2006 08:50:00 8 0.8 9.5 4.9 6.8 1.1 9.1 3.8 7.9 1 9.9 4.9 12 6 15 165 9.6 0 10.3 9.3 06/15/2006 09:00:00 8 0.9 11.5 5.7 7.1 1.2 11.5 4.2 7.9 1 11.5 5.3 14 6 22 165 9.6 0 9.8 9.3 06/15/2006 09:10:00 9.1 0.8 12.2 7.6 7.6 1.5 11.5 4.2 9.1 1 11.8 6.8 11 7 15 165 9.6 0.1 9.8 9 06/15/2006 09:20:00 8.5 1.1 11.8 5.3 6.6 1.5 11.1 3.8 8.3 1.1 11.5 6.1 6 9 12 165 9.8 0 9.8 9.3 06/15/2006 09:30:00 9.1 1.2 12.2 5.3 7.5 1.4 11.1 3.4 9 1.3 12.2 5.7 10 6 7 165 9.8 0 10.1 9.6 06/15/2006 09:40:00 9.1 1 11.5 6.5 7.3 1.6 11.1 4.2 8.9 1 11.5 6.5 10 8 15 165 9.8 0 10.1 9.6 06/15/2006 09:50:00 8.4 0.9 10.3 4.9 7.2 1.3 9.5 3.4 8.5 1 11.1 4.6 12 6 6 165 9.8 0 9.8 9.6 06/15/2006 10:00:00 8.3 1 11.1 5.7 6.7 1.2 9.9 4.2 8.2 1.1 11.5 5.7 10 7 7 165 9.8 0 9.8 9.6 06/15/2006 10:10:00 8.1 1 10.3 5.7 6.3 1.2 9.5 3.4 8.1 1 10.7 5.3 8 6 2 165 10 0 10.1 9.6 06/15/2006 10:20:00 8.6 1 11.1 5.7 6.2 1.1 9.1 3.8 8.6 1 10.7 5.7 5 7 4 165 10 0 10.1 9.6 06/15/2006 10:30:00 8.6 1.1 12.2 6.1 6.5 1.2 9.5 3.4 8.6 1.1 11.8 5.3 7 6 9 165 10 0 10.3 9.8 06/15/2006 10:40:00 8.9 1.1 11.8 6.1 6.6 1.2 9.9 4.2 8.8 1 11.8 6.8 5 6 3 165 10.1 0 10.3 9.8 06/15/2006 10:50:00 9.2 1 11.8 6.5 7.2 1.5 10.7 4.2 9 1.2 12.2 6.5 8 6 4 165 10 0 10.6 9.8 06/15/2006 11:00:00 8.8 1 11.8 5.7 6.5 1.2 11.1 4.2 8.7 1.1 11.1 5.7 5 8 10 165 10.1 0 10.6 9.8 06/15/2006 11:10:00 7.7 0.8 9.9 5.3 6.4 1.2 9.5 3.4 7.6 0.9 9.5 5.3 12 9 26 165 10.2 0 10.3 10.3 06/15/2006 11:20:00 8.1 0.8 10.3 5.7 7.3 1.1 10.3 3.8 8.2 0.8 10.3 5.3 16 6 25 165 10.1 0 10.3 9.8 06/15/2006 11:30:00 8.9 1.1 11.8 5.3 7.7 1.2 9.9 3.4 8.7 1.1 11.8 5.7 13 6 8 165 10.1 0 10.3 10.1 06/15/2006 11:40:00 8.6 1 10.7 5.3 7.5 1.3 10.3 3.8 8.4 1 11.5 6.1 14 7 360 165 10.2 0 10.3 10.1 06/15/2006 11:50:00 8.5 0.7 9.9 6.5 8 0.8 9.9 5.7 8.2 0.8 9.9 5.7 19 6 23 165 10.1 0 10.3 10.1 06/15/2006 12:00:00 9.5 0.9 12.2 6.8 9 1.1 11.5 6.5 9.1 1.1 11.8 6.1 18 8 27 165 10 0 10.1 9.8 06/15/2006 12:10:00 8.6 1.1 11.8 6.1 7.8 1.3 10.7 4.2 8.3 1 11.1 5.3 15 7 14 165 10 0 10.1 9.8 06/15/2006 12:20:00 8.6 1.1 11.5 6.1 7.8 1.2 11.1 4.6 8.4 1.1 11.8 6.5 16 7 18 165 10 0 10.1 9.8 06/15/2006 12:30:00 9.5 1.3 12.6 5.7 8.5 1.5 12.2 4.6 9.3 1.3 13 6.8 15 7 1 165 10 0 10.1 9.8 06/15/2006 12:40:00 10.1 1.1 12.2 7.2 8.6 1.4 11.8 5.3 10.1 1 12.6 7.2 12 7 18 165 9.9 0 10.3 9.8 06/15/2006 12:50:00 9.1 1 11.1 6.5 7.8 1.3 10.7 4.6 8.9 1 11.5 6.5 13 6 13 165 9.8 0 9.8 9.6 06/15/2006 13:00:00 9.5 1 11.5 6.5 7.6 1.2 10.3 3.4 9.3 1 11.5 6.5 10 6 9 165 9.8 0 10.3 9.6 06/15/2006 13:10:00 9.8 1 12.6 7.2 9 1.2 11.8 5.7 9.7 1 13 6.1 16 6 11 165 10 0 10.3 9.6 06/15/2006 13:20:00 9.8 1.1 12.6 6.8 8.4 1.4 11.5 4.9 9.7 1.2 12.6 6.1 12 6 10 165 10.1 0 10.3 9.8 06/15/2006 13:30:00 9.1 1.3 13.3 5.7 7.9 1.6 12.6 4.2 8.8 1.3 12.6 5.7 12 8 16 165 10 0 10.6 9.8 06/15/2006 13:40:00 10.6 1.2 13.3 8 8.8 1.5 13 4.9 10.5 1.2 13.7 6.5 10 7 16 165 10 0 10.3 9.8 06/15/2006 13:50:00 9.6 1 12.2 6.8 7.8 1.2 10.7 4.6 9.4 1 12.6 6.8 10 6 5 165 10.1 0 10.6 9.8 06/15/2006 14:00:00 9.3 1.2 12.2 6.1 7.9 1.4 11.5 4.2 9.2 1.2 13 6.1 11 7 13 165 10.1 0 10.3 9.8 06/15/2006 14:10:00 8.9 1 11.8 6.5 7.1 1.2 11.1 4.2 8.8 1.1 11.8 6.1 8 7 12 165 10.1 0 10.3 9.8 06/15/2006 14:20:00 9.4 1 11.8 6.8 8 1.3 11.5 4.6 9.2 1.1 11.5 6.5 12 8 11 165 10.1 0 10.3 9.8 06/15/2006 14:30:00 9.3 1.2 12.6 6.1 8.3 1.3 11.1 3.8 9.2 1.3 13 6.1 14 7 6 165 10.1 0 10.6 9.8 06/15/2006 14:40:00 9.2 1 11.5 6.5 8.3 1.2 11.5 4.6 8.8 1.1 11.5 6.5 15 6 21 165 10.1 0 10.9 9.8 06/15/2006 14:50:00 9.5 1.1 12.2 6.8 7.7 1.3 11.8 4.9 9.6 1.1 13 7.2 10 7 16 165 10 0 10.3 9.8 06/15/2006 15:00:00 9.2 1 11.8 6.5 7.5 1.2 10.7 4.9 8.9 1.1 11.8 5.7 10 6 15 165 10.1 0 10.3 9.8 06/15/2006 15:10:00 9.1 1 11.8 6.5 7.4 1.2 10.7 4.2 9.1 1 11.5 6.8 9 8 8 165 10.1 0 10.3 9.8 06/15/2006 15:20:00 9.9 1 11.8 7.6 7.8 1.2 11.1 5.3 9.8 1 12.6 7.2 9 6 14 165 10.2 0 10.3 10.3 06/15/2006 15:30:00 9.9 1.2 12.6 6.8 7.9 1.6 11.8 4.6 9.8 1.4 13 6.1 10 6 12 165 10.2 0 10.3 10.1 06/15/2006 15:40:00 9.9 1.3 13 6.5 7.6 1.3 10.7 4.6 9.8 1.4 13.3 5.7 8 6 5 165 10.2 0 10.3 10.1 06/15/2006 15:50:00 9.2 1 11.8 6.1 7.4 1.5 10.7 4.2 9 1.1 11.8 6.5 10 8 7 165 10.2 0 10.3 10.3 06/15/2006 16:00:00 8.9 1.2 11.8 5.3 7.4 1.5 11.5 3.4 8.8 1.3 11.8 5.7 11 7 11 165 10.2 0 10.3 10.3 06/15/2006 16:10:00 8.9 1.1 11.8 6.1 6.9 1.2 10.3 3.4 8.8 1.3 11.8 5.3 8 7 5 165 10.2 0 10.3 10.1 06/15/2006 16:20:00 9.1 1.3 12.6 6.1 7.1 1.3 11.1 4.2 9 1.3 12.2 6.1 8 8 7 165 10.2 0 10.3 10.3 06/15/2006 16:30:00 10 1.1 13 6.8 7.5 1.3 10.7 4.6 9.9 1.1 12.2 7.2 7 6 8 165 10.2 0 10.3 10.3 06/15/2006 16:40:00 9.7 1.4 13.7 6.1 7.6 1.6 12.2 4.6 9.6 1.4 13.7 6.1 9 7 12 165 10.2 0 10.6 10.3 06/15/2006 16:50:00 9.9 1 13 6.1 8.2 1.3 11.8 4.6 9.8 1.1 13 5.7 11 7 4 165 10.2 0 10.3 10.3 06/15/2006 17:00:00 10.1 1.3 14.1 7.2 7.9 1.3 12.6 4.2 10 1.4 13.7 6.8 8 8 2 165 10.2 0 10.9 10.3 06/15/2006 17:10:00 10 1 12.2 7.2 8 1.5 11.8 4.6 9.8 1.2 12.6 6.5 10 7 6 165 10.2 0 10.6 10.3 06/15/2006 17:20:00 9.7 1.2 13 6.8 8.1 1.5 11.5 4.9 9.5 1.3 13 6.5 11 7 7 165 10.1 0 10.3 10.1 06/15/2006 17:30:00 9.1 1 11.5 6.5 7.6 1.2 10.7 4.6 8.9 1 11.5 6.5 11 8 14 165 10.1 0 10.6 10.1 06/15/2006 17:40:00 8.3 1.1 10.7 5.7 6.7 1.2 10.3 3.4 8.1 1 10.7 5.7 10 7 14 165 10.1 0 10.3 10.1 06/15/2006 17:50:00 8.7 1 11.1 6.1 7.4 1.3 10.7 4.2 8.6 1.1 11.1 5.7 12 7 12 165 10.2 0 10.3 10.1 06/15/2006 18:00:00 9 1.2 11.8 5.7 7.6 1.5 11.5 4.6 8.7 1.3 11.8 5.7 12 8 21 165 10.1 0 10.3 9.8 06/15/2006 18:10:00 8.7 1 11.8 6.1 7 1.4 11.5 3.8 8.6 1 11.5 5.7 10 8 12 165 10.1 0 10.6 9.8 06/15/2006 18:20:00 9 1.2 12.2 6.1 6.9 1.5 10.3 3.4 9 1.2 13.3 6.5 8 7 11 165 10.1 0 10.3 9.8 06/15/2006 18:30:00 8.7 1.3 11.8 5.7 7.5 1.4 11.5 4.2 8.7 1.2 12.2 5.7 13 8 4 165 10.1 0 10.9 9.8 06/15/2006 18:40:00 8.7 0.9 11.1 6.1 7.8 1.2 11.5 4.6 8.5 1 11.1 5.7 16 8 24 165 10 0 10.6 9.8 06/15/2006 18:50:00 8.9 1.3 12.2 6.1 8.2 1.6 11.8 4.6 8.8 1.3 12.2 5.7 19 8 21 165 10 0 10.1 9.8 06/15/2006 19:00:00 8.8 1.1 11.5 6.1 8.2 1.3 11.1 3.8 8.7 1.2 11.8 5.7 18 9 2 165 9.9 0 10.6 9.6 06/15/2006 19:10:00 9.3 1 11.8 6.5 8.6 1.3 11.8 5.3 9.2 1.1 11.5 6.1 18 8 26 165 9.9 0 10.1 9.6 06/15/2006 19:20:00 8.5 1 11.1 6.1 8.1 1.2 11.1 4.9 8.4 1.1 11.1 5.7 20 8 27 165 9.8 0 9.8 9.6 06/15/2006 19:30:00 8.1 1 10.7 5.3 7.5 1.3 11.1 3.4 8.1 1 11.1 5.7 20 8 23 165 9.8 0 10.3 9.6 06/15/2006 19:40:00 7.9 0.8 10.3 5.7 7.6 1 10.3 4.6 7.7 0.9 9.9 5.3 23 7 22 165 9.8 0 9.8 9.6 06/15/2006 19:50:00 8 0.9 10.7 5.3 7.8 1 10.3 4.2 8 1 10.7 5.7 27 8 29 165 9.7 0 10.3 9.6 06/15/2006 20:00:00 7.7 1 9.9 4.9 7.6 1 9.9 4.9 7.6 1.1 9.9 4.9 29 7 30 165 9.6 0 9.8 9.6 06/15/2006 20:10:00 7.9 0.8 9.9 5.7 7.8 0.9 9.9 5.3 7.8 0.8 10.3 5.7 30 6 40 165 9.6 0 9.6 9.6 06/15/2006 20:20:00 7.2 0.9 9.1 4.9 7.1 1 9.5 4.6 7.1 1 9.9 4.6 29 8 29 165 9.6 0 9.6 9.6 06/15/2006 20:30:00 6.7 0.9 9.1 4.6 6.5 1 9.1 3.4 6.6 0.8 8.4 4.6 27 8 33 165 9.5 0 9.6 9.3 06/15/2006 20:40:00 7.1 0.8 8.8 3.8 6.9 0.9 8.8 3.4 6.9 0.7 8.8 4.9 28 6 35 165 9.4 0 9.6 9.3 06/15/2006 20:50:00 6.9 0.8 9.1 4.9 6.7 0.9 9.1 4.6 6.7 0.9 8.8 4.2 28 6 31 165 9.4 0 9.6 9.3 06/15/2006 21:00:00 6.3 1 8.4 3.4 6.1 1 8 3.8 6.1 0.9 8.4 3.4 26 8 25 165 9.5 0 9.6 9.3 06/15/2006 21:10:00 6.8 0.6 8 4.6 6.7 0.7 8.4 4.6 6.8 0.8 8.4 4.6 29 5 31 165 9.4 0 10.1 9.3 06/15/2006 21:20:00 6.5 0.9 8 4.2 6.3 0.9 8.4 3.8 6.4 0.8 8.4 4.2 25 6 31 165 9.4 0 9.6 9.3 06/15/2006 21:30:00 6.4 0.8 8.8 3.8 6.2 0.9 8.4 3.8 6.2 0.8 8.4 4.6 23 7 21 165 9.4 0 9.6 9.3 06/15/2006 21:40:00 6.2 0.7 8 3.8 5.9 0.7 8 3.8 6.2 0.7 8.4 4.6 22 7 30 165 9.5 0 9.6 9.3 06/15/2006 21:50:00 6 0.8 7.6 3.8 5.8 0.9 7.6 3.8 5.9 0.9 8 3.8 25 6 18 165 9.5 0 9.6 9.3 06/15/2006 22:00:00 6 0.6 8 4.6 5.8 0.7 7.6 3.8 5.8 0.7 7.2 3.8 24 6 25 165 9.4 0 9.8 9 06/15/2006 22:10:00 5.1 0.9 7.2 3 4.8 1 7.2 1.9 5.1 0.8 7.2 3.4 22 8 23 165 9.4 0 9.6 9 06/15/2006 22:20:00 6.4 1 8.4 3 6.1 1 8.4 2.6 6.3 1 8 3.4 23 7 16 165 9.4 0 9.6 9 06/15/2006 22:30:00 6.6 0.8 9.1 4.6 6.3 0.8 8.8 4.6 6.5 0.9 9.1 4.6 24 7 19 165 9.5 0 10.1 9 06/15/2006 22:40:00 6.9 0.8 9.1 4.6 6.5 0.8 8.4 3.8 6.9 0.8 9.1 4.2 20 5 15 165 9.6 0 9.6 9.3 06/15/2006 22:50:00 6.3 0.8 8.4 4.2 5.7 1 8.4 3 6.2 0.8 8.4 4.2 16 7 23 165 9.6 0 9.8 9.3 06/15/2006 23:00:00 5.6 0.9 8 3.4 5.4 1 7.6 3 5.6 0.9 8 3 22 7 26 165 9.6 0 9.8 9.3 06/15/2006 23:10:00 6.3 0.8 8.4 4.2 6 0.8 8.4 3.8 6.3 0.8 8.8 4.6 20 6 23 165 9.6 0 9.6 9.3 06/15/2006 23:20:00 6.3 0.7 8 4.2 5.6 0.9 8 3.4 6.3 0.7 8.8 4.2 16 6 23 165 9.6 0 9.6 9.3 06/15/2006 23:30:00 5.6 0.9 7.6 3.4 4.8 1.2 7.6 1.9 5.7 0.8 7.6 4.2 13 6 16 165 9.6 0 9.8 9.3 06/15/2006 23:40:00 6.5 0.8 8.4 4.2 5.7 1.2 7.6 2.6 6.4 0.8 8.4 4.6 14 7 20 165 9.6 0 9.8 9.3 06/15/2006 23:50:00 6.1 0.8 8 4.2 5.6 1 8 3 5.9 0.8 8 4.2 17 8 15 165 9.6 0 9.8 9.3 06/16/2006 00:00:00 5.7 0.7 7.2 3.8 5 0.9 6.8 2.3 5.6 0.7 7.6 3.8 15 7 15 165 9.6 0 9.8 9.3 06/16/2006 00:10:00 5.7 0.8 7.6 3.8 5.1 0.9 6.8 3 5.6 0.8 7.6 3.8 17 7 7 165 9.6 0 10.3 9.3 06/16/2006 00:20:00 5.5 0.8 8 3.4 5.1 1 7.6 2.6 5.5 0.9 7.6 3.4 17 7 17 165 9.6 0 9.8 9.6 06/16/2006 00:30:00 6.1 0.7 7.6 4.2 5.8 0.7 7.6 3.8 6 0.7 7.6 4.6 20 5 20 165 9.6 0 9.8 9.6 06/16/2006 00:40:00 5.9 0.5 6.8 4.6 5.5 0.6 6.5 3.4 5.7 0.6 6.8 4.2 18 5 16 165 9.6 0 10.1 9.6 06/16/2006 00:50:00 5.9 0.7 7.2 4.2 5.3 0.9 7.2 2.6 5.9 0.7 7.6 4.2 16 6 20 165 9.6 0 9.8 9.6 06/16/2006 01:00:00 5.5 0.9 8.4 3.4 4.9 1.1 8.4 2.3 5.7 0.8 7.6 3.8 16 7 24 165 9.6 0 9.8 9.6 06/16/2006 01:10:00 5.4 0.7 7.2 3.8 4.9 0.8 7.2 2.6 5.5 0.8 7.6 3.8 17 6 16 165 9.6 0 9.8 9.6 06/16/2006 01:20:00 5.1 0.6 6.5 3.8 4.6 0.9 6.5 1.9 5.1 0.6 6.8 3.8 16 7 19 165 9.6 0 9.8 9.6 06/16/2006 01:30:00 5.6 0.6 6.8 3.4 4.8 0.8 6.5 2.6 5.5 0.6 6.8 3.8 13 7 13 165 9.6 0 9.8 9.6 06/16/2006 01:40:00 5.8 0.7 8 4.2 4.8 1 7.2 3 5.7 0.7 7.6 4.2 11 5 10 165 9.6 0 9.8 9.6 06/16/2006 01:50:00 5.7 0.7 7.6 3.8 5 0.8 6.8 3 5.7 0.7 7.6 4.2 15 6 12 165 9.6 0 9.6 9.6 06/16/2006 02:00:00 5.3 0.6 6.8 3.8 4.5 0.8 6.1 2.3 5.4 0.6 6.8 4.2 13 6 18 165 9.6 0 9.6 9.6 06/16/2006 02:10:00 6.6 0.6 8 4.9 5.6 0.9 7.6 3 6.4 0.7 8.4 4.9 14 6 18 165 9.6 0 9.6 9.3 06/16/2006 02:20:00 6.3 0.6 8.4 4.6 5.7 0.8 7.2 3.4 6.1 0.7 7.6 4.2 15 5 14 165 9.5 0 9.6 9.3 06/16/2006 02:30:00 5.8 0.6 7.6 3.8 5 1 7.2 2.6 5.6 0.6 7.2 4.2 14 6 18 165 9.5 0 9.6 9 06/16/2006 02:40:00 5.7 0.7 7.2 3.8 5.3 0.8 6.8 3 5.5 0.7 7.2 3.8 20 8 23 165 9.5 0 9.8 9 06/16/2006 02:50:00 5.3 0.8 7.2 3.4 5 0.9 7.2 2.6 5.3 0.9 7.6 3.4 19 7 18 165 9.5 0 9.6 9 06/16/2006 03:00:00 5.6 0.6 7.2 3.8 5.2 0.8 6.8 2.3 5.5 0.6 7.2 3.8 20 7 18 165 9.5 0 9.6 9 06/16/2006 03:10:00 5.4 0.6 6.8 3.4 4.9 0.8 6.8 2.3 5.3 0.7 6.8 3.8 16 7 11 165 9.5 0 9.8 9 06/16/2006 03:20:00 5.6 0.7 7.6 4.2 5.1 0.9 7.6 3 5.6 0.6 7.6 4.2 17 7 16 165 9.4 0 9.6 9 06/16/2006 03:30:00 5.5 0.9 7.6 3.4 5 1.2 7.6 2.3 5.4 0.9 7.2 3 17 8 23 165 9.4 0 9.6 9 06/16/2006 03:40:00 5.9 0.6 7.2 4.2 5.5 0.7 7.2 3.4 5.8 0.6 7.2 4.2 20 6 22 165 9.4 0 9.6 9 06/16/2006 03:50:00 6.2 0.7 7.6 4.2 5.9 0.8 7.6 3.4 6.1 0.7 7.6 4.2 21 5 23 165 9.3 0 9.6 9 06/16/2006 04:00:00 6.1 0.5 7.6 4.6 5.8 0.6 7.2 4.2 5.9 0.6 7.6 4.2 20 5 14 165 9.3 0 9.6 9 06/16/2006 04:10:00 5.6 0.4 6.5 4.6 5.4 0.5 6.5 3.4 5.6 0.6 6.8 4.2 20 6 23 165 9.3 0 9.3 8.8 06/16/2006 04:20:00 6.2 0.4 7.2 4.9 5.7 0.6 6.8 3.4 6.2 0.5 7.2 4.6 17 4 14 165 9.3 0 9.3 8.8 06/16/2006 04:30:00 6.3 0.4 6.8 4.6 6 0.4 6.8 4.2 6.2 0.5 7.2 4.9 20 3 21 165 9.2 0 9.3 8.8 06/16/2006 04:40:00 6.1 0.4 6.8 4.9 5.4 0.6 6.5 3 6.1 0.4 7.2 4.6 16 5 21 165 9.2 0 9.3 8.8 06/16/2006 04:50:00 6.2 0.3 6.8 5.3 5.4 0.6 6.5 3.4 6.1 0.5 6.8 4.6 14 3 14 165 9.1 0 9.3 8.8 06/16/2006 05:00:00 5.8 0.4 6.8 4.6 5.2 0.5 6.5 3 5.8 0.5 6.8 4.6 15 3 14 165 9.1 0 9.3 9 06/16/2006 05:10:00 5.7 0.3 6.5 4.6 4.8 0.6 6.1 3 5.7 0.4 6.5 4.6 13 3 16 165 9.1 0 9.3 9 06/16/2006 05:20:00 5.8 0.4 6.5 4.9 4.6 0.8 6.5 2.3 5.8 0.5 6.8 4.6 12 3 14 165 9.1 0 9.3 9 06/16/2006 05:30:00 5.4 0.5 6.5 4.2 4.5 0.8 6.1 2.6 5.3 0.6 6.8 3.8 13 6 8 165 9.1 0 9.3 9 06/16/2006 05:40:00 5.5 0.5 6.5 4.2 4.5 0.8 6.1 2.3 5.5 0.6 6.8 3.8 12 5 21 165 9.1 0 9.3 9 06/16/2006 05:50:00 5.1 0.5 6.5 3.8 4.5 0.6 5.7 2.6 5.1 0.5 6.5 3.8 15 4 7 165 9.2 0 9.3 9 06/16/2006 06:00:00 4.8 0.5 6.1 3.4 4.2 0.8 6.1 1.9 4.8 0.5 6.5 3.4 15 5 14 165 9.2 0 9.6 9 06/16/2006 06:10:00 5.2 0.5 6.5 3.8 4.4 0.8 6.1 2.3 5.2 0.6 6.8 3.8 14 6 360 165 9.2 0 9.3 9 06/16/2006 06:20:00 5.1 0.5 6.8 3.8 4.8 0.6 6.1 2.6 5.2 0.5 6.5 3.8 19 6 19 165 9.2 0 9.3 9 06/16/2006 06:30:00 4.9 0.4 6.1 3.8 4.7 0.5 6.1 2.6 5 0.5 6.1 3.4 20 4 21 165 9.2 0 9.3 9 06/16/2006 06:40:00 4.4 0.4 5.7 3 4.1 0.5 4.9 2.3 4.3 0.5 5.7 2.6 18 4 7 165 9.2 0 9.3 9 06/16/2006 06:50:00 4.7 0.5 5.7 3 4.1 0.8 5.3 1.9 4.8 0.5 5.7 3.4 14 6 12 165 9.3 0 9.3 9 06/16/2006 07:00:00 4.9 0.5 6.1 3.8 4.5 0.7 6.1 1.9 4.9 0.4 5.7 3.8 18 5 24 165 9.3 0 9.3 9 06/16/2006 07:10:00 4.7 0.4 6.1 3.4 4.3 0.6 6.1 2.3 4.9 0.5 6.1 3.4 16 5 22 165 9.4 0 9.6 9 06/16/2006 07:20:00 5.1 0.4 6.1 4.2 4.5 0.7 6.1 2.3 5.1 0.4 6.8 3.8 16 5 12 165 9.4 0 9.6 9 06/16/2006 07:30:00 5.2 0.5 6.5 3.4 4.3 0.8 5.7 1.5 5.3 0.5 6.5 3.8 13 5 15 165 9.6 0 9.6 9 06/16/2006 07:40:00 5.4 0.4 6.5 4.2 4.4 0.6 6.1 2.6 5.6 0.5 6.8 3.8 12 5 11 165 9.6 0 9.8 9.3 06/16/2006 07:50:00 5.1 0.4 6.1 3.4 4.3 0.7 5.7 2.3 5.3 0.4 6.1 4.2 13 4 1 165 9.8 0 9.8 9.6 06/16/2006 08:00:00 5.1 0.4 6.1 3.4 4.5 0.6 6.1 2.6 5.2 0.5 6.5 3.8 16 5 15 165 9.9 0 10.1 9.6 06/16/2006 08:10:00 5.3 0.5 6.5 3.8 4.8 0.6 6.1 2.6 5.5 0.6 6.8 4.2 17 5 18 165 9.9 0 9.8 9.6 06/16/2006 08:20:00 5.4 0.4 6.5 4.2 4.5 0.7 6.1 2.3 5.6 0.5 6.8 3.8 13 5 17 165 10 0 10.3 9.6 06/16/2006 08:30:00 5.3 0.6 6.5 3.8 5 0.7 6.5 3 5.3 0.6 6.8 3.8 21 6 17 165 10.1 0 10.3 9.8 06/16/2006 08:40:00 5.5 0.5 6.5 4.2 5 0.6 6.5 3 5.6 0.6 7.2 3.8 20 6 18 165 10 0 10.3 9.6 06/16/2006 08:50:00 4.8 0.6 6.5 2.6 4.5 0.8 6.1 1.9 5.1 0.6 6.8 3 21 8 23 165 10 0 10.3 9.6 06/16/2006 09:00:00 4.7 0.6 5.7 3 4.5 0.7 5.7 1.9 4.9 0.6 6.1 3.4 22 6 25 165 10 0.1 10.3 9.6 06/16/2006 09:10:00 4.2 0.4 5.3 2.6 3.9 0.6 5.3 1.5 4.5 0.5 6.1 3 22 7 17 165 10 0.1 10.3 9.3 06/16/2006 09:20:00 4.5 0.5 6.1 2.6 4.4 0.6 6.1 1.9 4.7 0.5 5.7 3 25 6 29 165 10.1 0.2 10.6 9.3 06/16/2006 09:30:00 4.9 0.6 6.5 3 4.7 0.7 6.1 2.6 5.1 0.7 6.8 3.4 26 8 4 165 10.2 0.1 10.6 9.6 06/16/2006 09:40:00 5.1 0.5 6.5 3 4.8 0.6 6.1 1.9 5.3 0.6 6.8 3.8 20 6 22 165 10.4 0 10.6 9.8 06/16/2006 09:50:00 4.7 0.6 5.7 3.4 4.6 0.6 5.7 3 4.8 0.6 6.1 3 25 7 26 165 10.1 0.1 10.6 9.8 06/16/2006 10:00:00 4.5 0.6 5.7 3 4.4 0.6 5.3 2.6 4.7 0.6 6.1 3.4 28 7 34 165 10.1 0.1 10.3 9.6 06/16/2006 10:10:00 4.4 0.5 5.7 2.6 4.2 0.6 5.3 2.6 4.6 0.5 5.7 3 22 8 22 165 10.2 0 10.6 9.8 06/16/2006 10:20:00 3.3 0.7 4.9 1.5 3.2 0.7 4.9 1.5 3.2 0.7 4.9 1.1 39 10 44 165 10.5 0 10.9 10.1 06/16/2006 10:30:00 2.3 0.5 3.4 0.7 2.3 0.6 3.4 0.7 2.4 0.5 3.4 1.1 41 12 50 165 10.6 0.1 10.9 10.1 06/16/2006 10:40:00 2.7 0.5 3.8 1.5 2.7 0.5 3.8 1.1 2.8 0.6 4.2 1.5 41 9 48 165 10.5 0.2 10.9 10.1 06/16/2006 10:50:00 2.7 0.6 3.8 1.1 2.7 0.6 4.2 1.1 2.8 0.7 3.8 0.4 81 28 111 165 10.7 0.2 11.1 10.3 06/16/2006 11:00:00 2.7 0.7 4.2 0.7 2.7 0.8 4.2 0.4 2.7 0.7 4.2 0.4 99 11 105 165 10.7 0.2 11.1 10.3 06/16/2006 11:10:00 3.3 0.8 4.9 0.4 3.3 0.8 4.9 0.4 3.3 0.8 5.3 0.4 111 14 113 165 10.9 0.2 11.1 10.6 06/16/2006 11:20:00 2.9 0.7 4.9 1.1 2.9 0.7 4.6 0.7 3 0.7 4.9 1.1 74 27 105 165 10.5 0.1 11.1 10.1 06/16/2006 11:30:00 1.8 0.7 3.8 0.4 1.7 0.8 3.8 0.4 1.9 0.8 3.8 0.4 66 41 140 165 10.5 0.2 11.1 10.1 06/16/2006 11:40:00 3.1 0.5 4.6 1.9 3.1 0.5 4.6 1.5 3.2 0.5 4.6 1.9 110 8 105 165 10.7 0.2 11.1 10.3 06/16/2006 11:50:00 2.9 0.4 4.2 1.5 2.9 0.4 3.8 1.9 3.1 0.5 4.2 1.1 64 27 40 165 10.4 0.2 10.9 9.8 06/16/2006 12:00:00 2.7 0.5 3.8 1.5 2.6 0.5 3.8 1.5 2.8 0.5 4.2 1.1 48 10 44 165 10.1 0.2 10.6 9.6 06/16/2006 12:10:00 2.5 0.6 3.8 0.7 2.4 0.7 3.8 0.4 2.7 0.6 3.8 1.1 43 12 39 165 10.1 0.2 10.6 9.6 06/16/2006 12:20:00 1.9 0.6 3.4 0.7 1.8 0.6 3.4 0.4 2.2 0.6 3.8 0.7 56 9 57 165 10.1 0.2 10.6 9.6 06/16/2006 12:30:00 1.8 0.8 3.8 0.4 1.8 0.8 3.8 0.4 1.8 0.8 3.8 0.4 83 32 75 165 10.4 0.3 10.9 9.8 06/16/2006 12:40:00 2.3 0.7 3.8 0.4 2.3 0.7 3.8 0.4 2.4 0.8 4.2 0.4 65 32 36 165 10.5 0.2 11.4 10.1 06/16/2006 12:50:00 2.5 0.5 3.8 1.1 2.4 0.5 3.8 1.1 2.7 0.5 3.8 1.5 32 14 29 165 10.4 0.2 10.9 9.8 06/16/2006 13:00:00 2.1 0.6 4.2 0.4 2.1 0.6 4.2 0.4 2.3 0.6 4.6 0.4 44 15 54 165 10.6 0.2 10.9 10.3 06/16/2006 13:10:00 1.9 0.7 3.4 0.4 1.9 0.7 3.4 0.4 1.9 0.7 3.4 0.4 43 28 8 165 10.7 0.1 11.1 10.3 06/16/2006 13:20:00 1.9 0.8 3.8 0.4 1.9 0.9 3.8 0.4 1.7 0.9 3.8 0.4 55 30 23 165 10.9 0.1 11.4 10.9 06/16/2006 13:30:00 1.6 0.7 3.4 0.4 1.5 0.8 3.4 0.4 1.5 0.9 3.8 0.4 36 24 7 165 10.7 0 10.9 10.6 06/16/2006 13:40:00 2 0.8 3.8 0.4 2 0.8 4.2 0.4 2.1 0.8 4.2 0.4 71 26 96 165 10.7 0.1 10.9 10.3 06/16/2006 13:50:00 2.8 0.4 3.8 1.1 2.8 0.4 3.8 1.1 2.8 0.4 3.8 1.5 73 27 106 165 10.7 0.2 11.1 10.3 06/16/2006 14:00:00 3 0.6 4.6 1.1 2.9 0.6 4.6 1.1 3.2 0.6 4.9 1.5 44 14 37 165 10.2 0.1 10.6 9.8 06/16/2006 14:10:00 3 0.6 4.2 1.1 2.9 0.7 4.2 0.7 3 0.6 4.2 1.1 56 15 52 165 10.5 0.2 10.9 9.8 06/16/2006 14:20:00 2.6 0.7 4.2 0.7 2.7 0.7 4.6 0.7 2.8 0.7 4.6 1.1 50 12 44 165 10 0.2 10.6 9.6 06/16/2006 14:30:00 2.3 1 4.2 0.4 2.3 1 4.2 0.4 2.6 1 4.2 0.4 43 13 29 165 10.1 0.2 10.9 9.6 06/16/2006 14:40:00 2.9 0.6 4.2 1.5 2.9 0.6 4.2 1.5 3.1 0.5 4.6 1.9 37 10 30 165 9.9 0.1 10.3 9.3 06/16/2006 14:50:00 2.9 0.3 3.8 1.9 2.9 0.3 3.8 1.9 3.2 0.3 3.8 2.3 28 7 18 165 10.1 0 10.3 9.8 06/16/2006 15:00:00 2.7 0.6 4.2 1.5 2.8 0.6 3.8 1.5 3.1 0.6 4.6 1.9 30 8 29 165 10.2 0 10.6 10.1 06/16/2006 15:10:00 2.8 0.7 4.2 0.7 2.8 0.7 4.2 0.4 3.1 0.7 4.2 1.1 37 11 41 165 10.1 0 10.6 9.8 06/16/2006 15:20:00 3.2 0.6 4.2 1.5 3.2 0.6 4.2 1.5 3.4 0.6 4.6 1.9 33 8 33 165 10.1 0 10.3 9.8 06/16/2006 15:30:00 3.6 0.5 4.6 1.9 3.6 0.5 4.6 1.9 3.9 0.5 5.3 2.6 34 8 36 165 10.1 0 10.3 9.6 06/16/2006 15:40:00 3.6 0.6 4.6 2.3 3.6 0.6 4.9 2.3 3.8 0.6 4.9 2.3 35 8 40 165 9.8 0 10.3 9.3 06/16/2006 15:50:00 3.6 0.5 4.9 2.3 3.6 0.5 4.9 2.3 3.8 0.5 4.9 2.3 32 8 31 165 9.8 0 9.8 9.6 06/16/2006 16:00:00 3.3 0.5 4.6 2.3 3.5 0.5 4.6 2.3 3.6 0.5 4.9 2.3 31 8 35 165 9.8 0 10.1 9.6 06/16/2006 16:10:00 3.2 0.6 4.6 1.1 3.4 0.6 4.9 1.1 3.3 0.5 4.9 1.5 38 9 55 165 10 0 10.3 9.6 06/16/2006 16:20:00 3.5 0.8 4.9 1.1 3.7 0.7 4.9 1.5 3.7 0.6 4.9 1.5 36 12 29 165 9.9 0 10.3 9.6 06/16/2006 16:30:00 3.8 0.9 5.3 1.1 3.9 0.8 5.3 1.5 4 0.6 5.3 2.6 34 9 45 165 9.9 0 10.3 9.6 06/16/2006 16:40:00 3.5 0.6 4.9 1.9 3.7 0.6 4.9 2.3 3.6 0.6 5.3 1.9 36 9 44 165 10.1 0.1 10.3 9.6 06/16/2006 16:50:00 3.6 0.6 5.3 2.3 3.8 0.6 5.3 2.6 3.7 0.6 5.3 2.3 37 11 31 165 10.1 0.1 10.3 9.6 06/16/2006 17:00:00 3.7 0.7 5.7 1.9 3.9 0.7 5.7 1.9 3.8 0.7 5.7 2.3 37 11 28 165 10.1 0.1 10.3 9.6 06/16/2006 17:10:00 3.1 0.7 4.9 1.1 3.2 0.6 4.9 1.5 3.3 0.6 4.9 1.5 30 12 34 165 10.1 0.1 10.6 9.8 06/16/2006 17:20:00 3.7 0.6 5.3 1.9 3.8 0.6 5.3 1.9 3.9 0.5 5.3 1.9 33 10 39 165 10 0 10.3 9.6 06/16/2006 17:30:00 3.8 0.7 5.7 2.3 3.8 0.7 5.7 2.3 3.9 0.6 5.7 2.3 27 10 34 165 10 0.1 10.3 9.6 06/16/2006 17:40:00 3.9 0.8 5.3 1.9 4 0.8 5.7 1.9 3.9 0.7 5.7 2.6 32 9 32 165 9.9 0 10.6 9.6 06/16/2006 17:50:00 4 0.5 5.3 2.3 3.9 0.6 5.3 1.9 4.2 0.5 5.7 2.6 25 8 23 165 9.8 0 9.8 9.3 06/16/2006 18:00:00 4.8 0.6 6.1 3 4.6 0.6 6.1 2.6 4.8 0.7 6.5 3 22 8 19 165 9.6 0.1 9.8 9.3 06/16/2006 18:10:00 5.4 0.5 6.8 4.2 5.3 0.6 6.5 3.8 5.4 0.6 6.8 3.8 22 6 18 165 9.7 0.2 9.8 9 06/16/2006 18:20:00 5.3 0.5 6.5 3.8 5 0.7 6.5 2.3 5.4 0.6 6.8 3.8 20 7 25 165 9.6 0.2 9.8 9 06/16/2006 18:30:00 5.6 0.5 6.8 3.8 5 0.7 6.5 3 5.8 0.6 7.2 3.8 16 6 18 165 9.6 0.1 9.6 9 06/16/2006 18:40:00 5.8 0.4 6.8 4.9 5.2 0.6 6.5 3 5.9 0.4 6.8 4.6 15 3 17 165 9.6 0.1 10.1 9 06/16/2006 18:50:00 6.1 0.5 7.2 4.6 5.1 0.8 6.8 2.6 6.2 0.5 7.2 4.9 13 5 13 165 9.7 0.1 9.8 9 06/16/2006 19:00:00 6.4 0.5 7.6 4.6 5.9 0.7 7.2 3.8 6.4 0.6 7.6 4.9 18 4 23 165 9.6 0.1 10.3 9.3 06/16/2006 19:10:00 6.4 0.6 8 4.6 6 0.7 8 3.4 6.4 0.6 8 4.6 19 5 27 165 9.6 0 9.8 9.3 06/16/2006 19:20:00 6.1 0.5 7.6 4.9 5.2 0.9 7.6 2.6 6.1 0.5 7.6 4.6 15 6 23 165 9.6 0 9.8 9.3 06/16/2006 19:30:00 6.4 0.5 7.6 4.9 5 1.1 7.6 2.3 6.4 0.6 7.6 4.9 11 5 10 165 9.6 0.1 10.1 9.3 06/16/2006 19:40:00 7 0.4 8 5.7 6.4 0.7 7.6 4.2 7 0.5 8.4 5.7 17 5 4 165 9.6 0 10.3 9.3 06/16/2006 19:50:00 6.5 0.4 7.6 5.3 4.6 0.9 6.5 3 6.5 0.5 7.6 4.9 8 5 13 165 9.8 0 10.3 9.3 06/16/2006 20:00:00 5.7 0.8 7.6 3.8 3.6 0.9 6.5 2.3 5.7 0.8 7.2 3.8 3 6 8 165 10.1 0.1 10.6 9.6 06/16/2006 20:10:00 4.7 0.5 6.1 3.4 3.3 0.8 5.3 1.5 4.9 0.5 6.5 3.8 357 7 0 165 10.1 0.1 10.6 9.6 06/16/2006 20:20:00 6.1 0.5 6.8 4.6 5.6 0.8 6.8 3 6.1 0.5 7.2 4.6 14 4 7 165 10.1 0.1 10.3 9.6 06/16/2006 20:30:00 6.3 0.6 7.6 4.6 5.4 0.8 6.8 3 6.2 0.7 7.6 4.6 13 5 13 165 10.2 0.1 10.3 9.6 06/16/2006 20:40:00 6.9 0.4 8 6.1 5.8 0.8 7.2 3.8 7 0.5 8.4 4.9 12 3 12 165 10.1 0.2 10.3 9.6 06/16/2006 20:50:00 6.4 0.5 8.4 5.3 5.5 0.9 8 3 6.4 0.6 8.4 4.9 14 5 17 165 10.1 0.2 10.3 9.6 06/16/2006 21:00:00 6.4 0.5 8 4.9 5.3 0.8 7.2 3 6.3 0.5 7.6 4.9 12 4 11 165 10.1 0.2 10.9 9.6 06/16/2006 21:10:00 6.9 0.5 8 5.7 6 0.8 7.6 4.2 6.8 0.6 8.4 5.3 13 5 11 165 10.1 0.2 10.3 9.6 06/16/2006 21:20:00 6.5 0.6 8 4.2 5.8 0.8 7.6 3 6.3 0.7 8 4.6 15 5 15 165 10.1 0.2 10.3 9.6 06/16/2006 21:30:00 6.9 0.7 8.4 4.6 5.9 0.8 8 3 6.8 0.7 8.8 4.6 13 6 5 165 10.1 0.1 10.6 9.6 06/16/2006 21:40:00 7.2 0.6 8.8 4.9 6.7 0.9 8.8 4.6 7.1 0.7 9.1 5.3 17 6 21 165 10.1 0.1 10.9 9.6 06/16/2006 21:50:00 7.3 0.6 9.1 5.7 6.8 1 8.4 3.8 7.2 0.7 9.9 5.3 19 6 14 165 10.1 0 10.3 9.6 06/16/2006 22:00:00 7.1 0.6 8.8 5.3 6.6 0.8 8.8 3.8 7 0.7 8.8 4.9 19 6 17 165 10.1 0 10.3 9.6 06/16/2006 22:10:00 6.1 1 8 3.4 5.9 1 8 3.4 6.2 1 8.4 3.4 24 7 26 165 10 0 10.1 9.6 06/16/2006 22:20:00 5.4 1.1 7.6 3 5.2 1.2 8 2.3 5.4 1 8.4 3.4 25 8 33 165 10 0 10.1 9.8 06/16/2006 22:30:00 6.3 0.6 7.6 4.9 6.3 0.6 7.6 4.6 6.4 0.7 8 4.6 29 5 28 165 9.8 0 10.3 9.6 06/16/2006 22:40:00 5.8 0.6 7.6 4.2 5.7 0.6 7.6 4.2 5.9 0.7 7.6 4.2 27 5 31 165 9.7 0 9.8 9.3 06/16/2006 22:50:00 5.9 0.6 8 3.8 5.9 0.7 7.6 3.8 6 0.7 7.6 3.8 27 6 19 165 9.6 0 10.3 9.3 06/16/2006 23:00:00 6 0.5 7.2 4.6 5.9 0.6 7.2 3.4 5.9 0.6 7.2 4.2 27 5 18 165 9.6 0.1 9.8 9 06/16/2006 23:10:00 5.4 0.6 6.5 3.8 5.3 0.7 6.8 3.4 5.3 0.6 6.8 3.8 27 5 34 165 9.6 0 10.1 9.6 06/16/2006 23:20:00 5.4 0.5 6.8 4.2 5.4 0.6 6.8 3.8 5.4 0.6 6.8 3.4 29 6 26 165 9.6 0 9.6 9.6 06/16/2006 23:30:00 5.7 0.4 6.8 4.6 5.7 0.5 6.8 4.6 5.8 0.5 7.2 4.6 28 4 31 165 9.6 0 9.6 9.6 06/16/2006 23:40:00 5.5 0.5 6.5 3.8 5.5 0.6 6.5 3.8 5.5 0.6 6.5 3.8 30 5 31 165 9.6 0 9.6 9.6 06/16/2006 23:50:00 5.5 0.5 6.8 4.2 5.5 0.5 6.8 3.8 5.6 0.6 7.2 3.8 34 4 39 165 9.6 0 9.6 9.6 06/17/2006 00:00:00 5.3 0.6 6.8 3.8 5.1 0.8 6.5 3 5.4 0.6 6.8 3.8 24 8 33 165 9.6 0 9.8 9.6 06/17/2006 00:10:00 5.2 0.7 6.8 3.8 5 0.7 6.5 3.4 5.2 0.7 6.8 3.8 26 8 22 165 9.6 0 10.3 9.6 06/17/2006 00:20:00 5.5 0.6 7.2 3.4 5.1 0.8 6.8 2.3 5.5 0.7 6.8 3.8 21 6 9 165 9.6 0 9.6 9.6 06/17/2006 00:30:00 5.6 0.7 6.8 3.8 5.4 0.8 6.8 3 5.8 0.8 7.6 4.2 24 5 21 165 9.4 0 9.6 9.3 06/17/2006 00:40:00 5.3 0.4 6.5 3.8 5.2 0.5 6.8 3.8 5.4 0.5 6.8 4.2 29 4 29 165 9.4 0 9.8 9.3 06/17/2006 00:50:00 4.7 0.3 5.3 3.4 4.7 0.4 5.3 3.4 4.9 0.4 5.7 3.4 33 3 31 165 9.4 0 9.3 9.3 06/17/2006 01:00:00 4.6 0.3 5.3 3.8 4.6 0.3 5.3 3.8 4.8 0.4 5.7 3.8 33 3 32 165 9.3 0 9.6 9 06/17/2006 01:10:00 4.4 0.4 5.3 3 4.4 0.5 5.3 3 4.6 0.5 5.7 3.4 28 5 29 165 9.3 0 9.3 9 06/17/2006 01:20:00 4 0.3 4.9 3.4 3.9 0.3 4.6 3 4.3 0.3 5.3 3.4 28 5 27 165 9.2 0 9.3 9 06/17/2006 01:30:00 3.6 0.4 4.6 2.6 3.6 0.5 4.6 2.3 3.8 0.4 4.6 2.6 32 6 33 165 9.1 0 9.6 8.8 06/17/2006 01:40:00 3.3 0.4 4.2 2.3 3.2 0.5 4.6 1.9 3.1 0.4 4.2 1.9 38 9 41 165 9.1 0 9.6 8.8 06/17/2006 01:50:00 3.6 0.4 4.6 2.6 3.5 0.4 4.6 2.6 3.7 0.4 4.6 2.6 31 6 40 165 9.2 0 9.3 8.8 06/17/2006 02:00:00 3.3 0.5 4.6 2.3 3.2 0.5 4.2 1.9 3.6 0.5 4.9 2.6 27 5 25 165 9.2 0 9.3 8.8 06/17/2006 02:10:00 3.4 0.4 4.6 2.3 3.3 0.5 4.6 2.3 3.7 0.4 4.6 2.6 27 5 29 165 9.2 0 9.3 8.8 06/17/2006 02:20:00 3.3 0.4 4.6 2.3 3.2 0.5 4.6 1.9 3.4 0.4 4.2 2.6 38 10 46 165 9.2 0 9.3 8.8 06/17/2006 02:30:00 3.5 0.7 5.3 2.3 3.4 0.7 5.3 1.9 3.5 0.6 5.3 2.3 46 11 63 165 9.2 0 9.3 8.8 06/17/2006 02:40:00 3.6 0.6 5.3 2.3 3.5 0.6 5.3 2.3 3.4 0.5 4.6 2.3 48 13 68 165 9.2 0 9.3 8.8 06/17/2006 02:50:00 3.5 0.4 4.9 2.3 3.4 0.5 4.6 2.3 3.7 0.4 4.6 2.6 36 5 36 165 9.1 0 9.6 8.8 06/17/2006 03:00:00 3.4 0.4 4.9 2.3 3.4 0.4 4.6 2.3 3.7 0.4 4.6 2.6 32 5 41 165 9 0 9.3 8.8 06/17/2006 03:10:00 3.2 0.3 3.8 2.6 3.1 0.3 3.8 2.3 3.4 0.3 4.2 2.3 32 4 33 165 9 0.1 9.6 8.8 06/17/2006 03:20:00 3.1 0.4 4.2 1.9 3 0.4 3.8 1.9 3.3 0.4 4.2 2.3 36 5 41 165 9 0.1 9 8.5 06/17/2006 03:30:00 2.6 0.4 3.8 1.5 2.5 0.5 3.8 1.5 2.9 0.5 4.2 1.9 37 9 65 165 9 0 9 8.5 06/17/2006 03:40:00 2.7 0.3 3.4 1.9 2.6 0.3 3.4 1.9 3 0.3 3.8 1.9 27 4 28 165 9 0 9.3 9 06/17/2006 03:50:00 2.5 0.3 3.4 1.9 2.4 0.3 3 1.5 2.8 0.3 3.4 1.9 26 5 23 165 9 0 9 9 06/17/2006 04:00:00 2.5 0.3 3.4 1.9 2.5 0.3 3.4 1.9 2.9 0.3 3.8 2.3 27 5 27 165 9 0 9 9 06/17/2006 04:10:00 2.8 0.3 3.4 1.9 2.7 0.3 3.4 1.9 3.1 0.3 3.8 1.9 31 4 31 165 9 0 9.3 9 06/17/2006 04:20:00 2.7 0.4 3.8 1.9 2.6 0.4 3.8 1.9 2.9 0.4 3.8 1.9 33 6 33 165 9 0 9 9 06/17/2006 04:30:00 3.1 0.6 4.9 1.9 3.2 0.6 4.6 1.9 2.9 0.5 4.2 1.5 54 11 68 165 9 0 9 9 06/17/2006 04:40:00 3.8 0.6 4.9 2.3 3.9 0.6 5.3 2.3 3.8 0.5 4.9 2.3 59 8 55 165 9.1 0 9.3 9 06/17/2006 04:50:00 3.6 0.6 5.3 2.3 3.8 0.7 5.7 2.3 3.6 0.6 5.7 1.9 67 9 72 165 9.1 0 9.3 9 06/17/2006 05:00:00 4.5 0.8 6.5 2.3 4.7 0.8 6.8 2.6 4.4 0.6 6.5 3 74 9 78 165 9.1 0 9.6 9 06/17/2006 05:10:00 5.4 0.7 7.2 3.4 5.6 0.8 7.2 3.4 5.3 0.6 6.8 3.8 87 8 88 165 9.1 0 9 9 06/17/2006 05:20:00 5.5 0.6 6.8 3.8 5.7 0.7 7.2 3.8 5.3 0.6 7.2 3.8 93 6 94 165 9 0 9 9 06/17/2006 05:30:00 5 0.6 6.5 3 5.2 0.6 6.8 3.4 4.9 0.6 6.1 3 92 6 95 165 9 0 9.3 9 06/17/2006 05:40:00 4.5 0.7 6.5 3 4.6 0.7 6.5 3 4.4 0.7 6.1 3 88 6 90 165 9 0 9 8.8 06/17/2006 05:50:00 4.2 0.7 5.7 2.6 4.4 0.7 6.1 2.6 4.2 0.6 6.1 2.6 83 8 86 165 9 0 9 8.5 06/17/2006 06:00:00 4.5 0.5 5.7 3 4.7 0.5 5.7 3.4 4.4 0.5 5.7 2.6 87 7 83 165 8.9 0 9.3 8.5 06/17/2006 06:10:00 3.6 0.6 5.3 2.3 3.7 0.6 5.3 2.6 3.5 0.6 4.9 2.3 72 15 89 165 9 0 9 8.5 06/17/2006 06:20:00 2.8 0.6 4.2 1.5 2.8 0.6 4.6 1.5 2.8 0.6 4.2 1.5 49 10 60 165 9 0.1 9 8.5 06/17/2006 06:30:00 3.3 0.5 4.2 1.5 3.3 0.6 4.2 1.5 3.3 0.6 4.6 1.5 38 6 34 165 9 0 9 8.5 06/17/2006 06:40:00 3.6 1 6.1 1.5 3.6 1.1 6.1 1.1 3.6 1 6.1 1.5 54 11 61 165 9 0.1 9.3 8.5 06/17/2006 06:50:00 2.9 0.8 4.9 1.1 2.8 0.9 5.3 0.7 3 0.8 5.3 1.5 54 9 58 165 9 0.1 9.3 8.5 06/17/2006 07:00:00 2.7 0.6 4.2 1.5 2.5 0.7 4.2 1.1 2.7 0.6 4.6 1.5 50 13 52 165 9 0 9.3 8.8 06/17/2006 07:10:00 2.8 0.4 3.8 1.9 2.8 0.4 3.8 1.5 2.9 0.5 4.2 1.9 41 7 35 165 9 0.1 9 8.5 06/17/2006 07:20:00 3 0.5 4.2 1.5 2.9 0.6 4.2 1.1 3.2 0.5 4.6 1.5 38 8 35 165 9 0.1 9 8.5 06/17/2006 07:30:00 2.5 0.6 4.9 0.7 2.5 0.6 5.3 0.4 2.8 0.5 4.2 1.1 51 13 64 165 9 0 9 8.8 06/17/2006 07:40:00 3 0.7 4.6 1.9 3 0.6 4.6 1.5 3.3 0.7 4.9 1.9 40 8 37 165 9 0 9 8.5 06/17/2006 07:50:00 4.1 0.8 5.7 2.3 4 0.8 5.3 1.5 4.2 0.8 6.5 2.3 27 8 18 165 9 0.1 9 8.5 06/17/2006 08:00:00 4 0.6 5.3 2.3 3.9 0.6 5.3 2.6 4.1 0.6 5.7 2.6 28 7 29 165 9 0 9.3 8.8 06/17/2006 08:10:00 3.5 0.5 4.6 2.3 3.5 0.5 4.6 2.3 3.6 0.5 4.9 2.3 34 7 39 165 9.1 0 9.3 9 06/17/2006 08:20:00 3.7 0.4 4.9 2.3 3.7 0.5 4.9 2.3 3.9 0.5 4.9 2.3 30 6 37 165 9.2 0 9.3 9 06/17/2006 08:30:00 3.3 0.6 5.3 1.5 3.2 0.6 4.9 1.1 3.5 0.6 4.6 2.3 24 8 22 165 9.3 0 9.6 9 06/17/2006 08:40:00 4.3 0.4 5.3 3 4.2 0.4 5.3 2.3 4.4 0.4 5.3 3 26 6 14 165 9.4 0 9.6 9.3 06/17/2006 08:50:00 4.1 0.6 5.3 2.6 4 0.6 5.3 2.3 4.1 0.5 5.3 2.6 28 7 33 165 9.5 0 9.6 9.3 06/17/2006 09:00:00 5 0.6 6.1 3.4 5 0.7 6.1 3 4.9 0.7 6.5 2.6 31 6 39 165 9.4 0 9.8 9.3 06/17/2006 09:10:00 5.6 1 7.6 3 5.5 1 7.2 2.6 5.5 1 8 3 30 6 19 165 9.4 0 9.6 9.3 06/17/2006 09:20:00 5.6 0.8 7.6 3.4 5.5 0.8 7.6 3.4 5.5 0.8 7.6 3.8 27 7 23 165 9.6 0 9.6 9.3 06/17/2006 09:30:00 6.6 0.8 8 4.2 6.4 0.9 8 3.8 6.4 0.8 8.8 4.2 29 7 46 165 9.6 0 9.6 9.6 06/17/2006 09:40:00 5.4 1 7.2 2.6 5.4 1 7.2 2.6 5.3 1 8 2.3 40 9 32 165 9.6 0 9.6 9.6 06/17/2006 09:50:00 5.2 1.7 9.5 2.3 5.3 1.8 9.9 2.6 5.2 1.6 8.8 2.6 73 12 88 165 9.6 0 9.6 9.3 06/17/2006 10:00:00 8.4 1.1 10.7 5.7 8.6 1.2 11.1 6.1 8 1.1 10.7 5.7 89 7 82 165 9.5 0 9.6 9.3 06/17/2006 10:10:00 8.5 1 10.3 5.7 8.7 1 10.3 5.7 8.1 1 9.9 5.7 94 7 103 165 9.5 0 9.6 9.3 06/17/2006 10:20:00 8.3 0.9 10.7 6.5 8.6 1 11.1 6.1 7.9 0.9 9.9 4.9 91 7 87 165 9.5 0 9.6 9 06/17/2006 10:30:00 7.8 1 9.5 4.9 8.1 1 9.9 4.9 7.6 1 9.9 4.9 87 6 85 165 9.4 0 9.6 9 06/17/2006 10:40:00 6.6 1 8.8 3.8 6.7 1 8.8 3.8 6.5 1 8.8 4.2 82 10 69 165 9.6 0 9.8 9.3 06/17/2006 10:50:00 5.9 0.9 7.6 3.8 6 1 7.6 3.8 6 0.8 7.6 4.2 85 9 90 165 9.6 0 9.8 9.3 06/17/2006 11:00:00 5.6 1.1 7.6 3 5.6 1.2 8 3 5.5 1 8 3 79 11 86 165 9.6 0 9.8 9.3 06/17/2006 11:10:00 5.4 1 8 2.6 5.4 1 8 3 5.2 0.9 8.4 3 84 11 94 165 9.6 0.1 10.3 9 06/17/2006 11:20:00 4.7 0.8 6.8 3 4.7 0.8 6.8 2.6 4.6 0.8 6.5 2.6 73 17 63 165 9.7 0 9.8 9.6 06/17/2006 11:30:00 4.7 1 7.2 2.6 4.7 1 7.2 2.3 4.7 1 7.2 2.6 66 12 60 165 9.7 0.1 10.3 9.3 06/17/2006 11:40:00 5.1 1.3 8.4 2.6 5.1 1.4 8.8 2.3 5.1 1.2 8.4 2.6 57 13 58 165 9.6 0 10.3 9.3 06/17/2006 11:50:00 4.9 1 7.2 1.9 4.7 1 6.8 1.9 4.7 1 6.8 1.9 41 11 46 165 9.3 0.1 9.6 9 06/17/2006 12:00:00 5.2 0.8 6.8 3 5 0.8 6.5 3 5.2 0.8 7.2 3 36 8 34 165 9.2 0 9.3 9 06/17/2006 12:10:00 3.8 0.6 5.3 1.9 3.7 0.7 4.9 1.5 3.8 0.7 5.7 1.9 47 12 37 165 9.3 0 9.6 9 06/17/2006 12:20:00 4.1 0.7 6.1 2.3 4 0.8 6.1 2.3 4.1 0.6 5.7 2.3 46 12 91 165 9.4 0 9.6 9 06/17/2006 12:30:00 4 1 7.2 2.3 4 1.1 7.2 1.9 3.9 0.8 6.1 1.9 53 13 63 165 9.4 0 9.6 9 06/17/2006 12:40:00 5.5 1.1 8.4 2.6 5.6 1.2 8.8 2.6 5.4 1.3 8.4 2.6 61 11 72 165 9.6 0 9.8 9.3 06/17/2006 12:50:00 5.8 1.1 8.4 3.4 5.9 1.1 8.4 3.4 5.6 0.9 7.6 3.4 59 10 69 165 9.6 0 10.3 9.6 06/17/2006 13:00:00 6 1 8.4 3.4 6 1 8.8 3.4 5.8 1 8 3.4 61 10 67 165 9.7 0 9.8 9.6 06/17/2006 13:10:00 5.6 0.9 8 3.4 5.7 1 8.4 3.4 5.6 0.9 8.8 3.4 65 9 70 165 9.8 0 10.1 9.6 06/17/2006 13:20:00 5.5 0.8 7.6 3.4 5.6 0.9 8 3 5.4 0.7 7.6 3.4 65 9 63 165 10 0 10.3 9.6 06/17/2006 13:30:00 5.8 0.8 7.6 3.4 5.8 0.9 8 3.4 5.9 0.8 8 3.8 63 8 56 165 10 0.1 10.3 9.3 06/17/2006 13:40:00 5.6 1.2 8.8 2.6 5.6 1.3 8.8 2.3 5.5 1.1 8.4 2.3 62 12 77 165 10 0.1 10.3 9.6 06/17/2006 13:50:00 4.1 1.1 6.8 2.3 4.1 1.1 6.8 1.9 4.1 1.1 6.8 1.9 58 13 66 165 10 0.1 10.3 9 06/17/2006 14:00:00 4.7 0.8 6.8 2.6 4.6 0.9 6.8 2.6 4.7 0.8 6.5 3 45 15 68 165 9.6 0.2 10.3 9 06/17/2006 14:10:00 4.1 0.6 6.1 2.6 3.9 0.6 6.1 2.6 4.1 0.6 6.1 2.3 42 9 50 165 9.4 0 9.6 8.8 06/17/2006 14:20:00 3.9 0.7 5.7 2.3 3.8 0.8 5.7 1.9 4 0.8 6.1 1.9 40 11 57 165 9.5 0.1 9.6 9 06/17/2006 14:30:00 4.3 0.9 6.8 1.9 4.2 0.9 6.8 1.9 4.2 0.8 6.1 2.3 42 13 39 165 9.6 0.1 9.8 9 06/17/2006 14:40:00 4 1 6.8 1.9 3.9 1 6.5 1.9 3.9 0.9 6.8 1.9 48 14 51 165 9.8 0 10.3 9.3 06/17/2006 14:50:00 4 0.7 5.3 1.9 3.9 0.7 5.7 1.9 4 0.8 5.7 1.5 35 11 54 165 9.7 0.1 9.8 9.3 06/17/2006 15:00:00 4.6 0.8 6.8 2.6 4.5 0.9 6.8 1.9 4.6 0.8 6.8 2.3 29 10 48 165 9.6 0.1 9.8 9 06/17/2006 15:10:00 4.7 0.7 6.8 3 4.5 0.8 6.8 2.6 4.7 0.6 6.8 3 25 9 25 165 9.6 0.1 10.3 9 06/17/2006 15:20:00 4.9 0.7 6.8 3.4 4.7 0.8 6.8 3 4.7 0.7 6.5 3 29 10 26 165 9.6 0.1 9.8 9 06/17/2006 15:30:00 5.4 0.8 6.8 3.4 5.4 0.8 6.8 3.4 5.3 0.8 7.2 3 31 9 37 165 9.6 0.1 9.8 9 06/17/2006 15:40:00 5.8 0.7 7.2 4.2 5.7 0.7 7.2 3.8 5.8 0.6 7.6 4.2 34 7 39 165 9.6 0.1 9.8 9 06/17/2006 15:50:00 4.9 0.9 7.2 3 4.8 0.9 7.2 3 4.9 0.8 7.2 3 31 9 32 165 9.6 0.1 9.8 9 06/17/2006 16:00:00 5.1 0.8 7.6 3.4 5.1 0.9 7.6 3.4 5.2 0.8 7.6 3.4 32 8 39 165 9.6 0 9.8 9.3 06/17/2006 16:10:00 4.9 0.7 6.5 3 4.8 0.7 6.5 3 4.8 0.7 6.5 3 31 8 34 165 9.6 0 9.6 9.3 06/17/2006 16:20:00 4.3 0.7 6.1 2.3 4.3 0.7 6.1 2.6 4.3 0.6 5.7 2.6 33 10 29 165 9.5 0 9.6 9.3 06/17/2006 16:30:00 3.5 0.7 5.3 1.9 3.5 0.7 5.3 1.5 3.6 0.7 5.3 1.9 34 11 37 165 9.6 0 9.6 9.3 06/17/2006 16:40:00 4.2 0.8 5.7 2.6 4.2 0.7 6.1 2.6 4.2 0.7 5.7 2.3 31 9 34 165 9.4 0 9.6 9 06/17/2006 16:50:00 4.3 0.6 5.7 2.3 4.3 0.6 5.7 2.3 4.4 0.7 6.1 2.6 35 7 24 165 9.4 0 9.6 9 06/17/2006 17:00:00 4.8 0.8 6.8 2.6 4.8 0.8 6.8 2.6 4.8 0.7 6.5 2.3 42 9 50 165 9.4 0 9.8 9 06/17/2006 17:10:00 5.2 0.7 6.8 3.4 5.2 0.7 6.8 3.4 5.2 0.7 6.8 3 35 8 31 165 9.4 0 9.6 9.3 06/17/2006 17:20:00 5.3 0.7 6.8 3 5.2 0.7 7.2 3.4 5.3 0.7 7.2 3.4 27 8 31 165 9.4 0 9.6 9.3 06/17/2006 17:30:00 5.4 0.6 6.8 3.8 5.3 0.6 6.8 3.8 5.4 0.7 6.8 3.8 26 7 31 165 9.4 0 9.6 9.3 06/17/2006 17:40:00 5 0.6 6.8 3 5 0.7 6.8 3 5.1 0.7 6.8 3 26 8 29 165 9.4 0 9.6 9.3 06/17/2006 17:50:00 5.5 0.6 6.8 3.8 5.3 0.7 7.2 3 5.5 0.7 7.6 3.8 22 6 23 165 9.4 0 9.6 9.3 06/17/2006 18:00:00 5.1 0.6 6.5 3.4 4.9 0.7 6.5 2.3 5 0.7 6.8 3.4 24 8 356 165 9.4 0 9.6 9.3 06/17/2006 18:10:00 4.6 0.7 6.1 2.6 4.6 0.8 6.5 2.6 4.7 0.7 6.5 3 27 8 27 165 9.3 0 9.6 9 06/17/2006 18:20:00 4.3 0.6 5.7 2.6 4.3 0.6 5.7 2.6 4.4 0.6 6.1 3 33 8 31 165 9.2 0 9.3 9 06/17/2006 18:30:00 4 0.5 4.9 2.6 4 0.5 5.3 2.6 4.1 0.5 5.7 3 40 7 43 165 9.2 0 9.3 9 06/17/2006 18:40:00 4 0.5 4.9 2.3 4 0.6 5.3 2.3 4.2 0.6 5.7 2.6 36 7 31 165 9.2 0 9.3 9 06/17/2006 18:50:00 4.2 0.7 5.7 2.3 4.3 0.7 6.1 2.3 4.3 0.7 6.1 2.3 39 9 43 165 9.2 0 9.3 9 06/17/2006 19:00:00 4.4 0.5 5.7 2.6 4.4 0.5 5.7 2.6 4.4 0.6 5.7 3 40 8 37 165 9.2 0 9.3 9 06/17/2006 19:10:00 4.5 0.5 5.7 2.6 4.4 0.6 5.7 3 4.5 0.6 5.7 2.6 34 8 42 165 9.3 0 9.3 9 06/17/2006 19:20:00 5 0.6 6.8 3.8 5 0.7 6.8 3.4 4.9 0.7 6.5 3.4 31 7 44 165 9.4 0 9.6 9.3 06/17/2006 19:30:00 4.5 0.6 5.7 2.6 4.5 0.7 6.1 1.9 4.6 0.7 5.7 2.6 29 8 34 165 9.3 0 9.8 9 06/17/2006 19:40:00 5 0.4 6.1 4.2 5.1 0.4 6.1 3.8 5.1 0.5 6.5 3.8 30 5 31 165 9.2 0 9.3 8.8 06/17/2006 19:50:00 4.6 0.5 6.5 3 4.6 0.6 6.1 3 4.6 0.5 6.1 3.4 28 7 34 165 9.1 0 9.3 8.8 06/17/2006 20:00:00 4.7 0.4 5.7 3.4 4.6 0.5 5.7 3 4.6 0.5 6.1 3.4 29 6 23 165 9.1 0 9.6 8.8 06/17/2006 20:10:00 4.6 0.5 5.7 3 4.6 0.6 5.7 3 4.6 0.6 6.1 3.4 29 6 27 165 9.1 0 9.3 8.8 06/17/2006 20:20:00 4.7 0.4 5.7 2.6 4.7 0.5 5.7 2.6 4.7 0.5 5.7 3.4 26 5 28 165 9.1 0 9.3 8.8 06/17/2006 20:30:00 4.5 0.5 5.7 2.3 4.5 0.6 5.7 1.9 4.6 0.5 5.7 2.6 27 5 25 165 9.1 0 9.3 8.8 06/17/2006 20:40:00 4.4 0.4 5.3 3.4 4.4 0.4 5.3 2.6 4.5 0.5 5.3 3 30 5 25 165 9.1 0 9.3 8.8 06/17/2006 20:50:00 4.3 0.5 5.7 3 4.3 0.5 5.7 3 4.4 0.5 6.1 3 31 5 35 165 9.1 0 9.3 8.8 06/17/2006 21:00:00 3.8 0.5 4.9 2.6 3.8 0.5 4.9 2.6 3.9 0.5 5.3 2.3 33 7 39 165 9.1 0 9.3 8.8 06/17/2006 21:10:00 3.3 0.5 4.6 2.3 3.2 0.5 4.6 1.9 3.2 0.5 4.6 1.9 36 8 30 165 9.1 0 9.3 8.8 06/17/2006 21:20:00 3.1 0.4 4.2 2.3 3.1 0.4 4.2 2.3 3.1 0.4 4.2 1.9 35 7 32 165 9.1 0 9.3 8.8 06/17/2006 21:30:00 3.3 0.7 4.6 1.5 3.3 0.7 4.6 1.5 3.3 0.7 4.9 1.5 36 8 40 165 9 0 9.3 8.8 06/17/2006 21:40:00 3.4 0.5 4.6 1.9 3.4 0.5 4.6 1.9 3.4 0.6 4.9 1.9 35 6 39 165 9 0 9 8.8 06/17/2006 21:50:00 3.5 0.5 4.9 2.3 3.5 0.6 4.9 1.9 3.5 0.5 4.6 2.3 32 6 37 165 9 0 9.3 9 06/17/2006 22:00:00 3.4 0.5 4.6 1.9 3.3 0.5 4.6 1.5 3.5 0.4 4.2 2.3 29 7 39 165 9 0 9.3 8.8 06/17/2006 22:10:00 3.4 0.4 4.2 2.3 3.3 0.4 4.2 1.9 3.6 0.4 4.6 2.3 26 4 28 165 8.9 0 9 8.8 06/17/2006 22:20:00 3.7 0.3 4.6 3 3.6 0.4 4.6 1.9 3.7 0.4 4.9 2.6 24 5 24 165 8.9 0 9 8.8 06/17/2006 22:30:00 3.6 0.4 4.6 2.3 3.5 0.4 4.6 2.3 3.8 0.4 4.6 2.6 25 4 25 165 8.8 0 9 8.8 06/17/2006 22:40:00 3.5 0.3 4.2 2.6 3.4 0.3 4.2 2.3 3.6 0.4 4.6 2.6 29 5 25 165 8.8 0 9 8.8 06/17/2006 22:50:00 3.5 0.3 4.2 2.6 3.5 0.3 4.2 2.6 3.6 0.3 4.2 2.6 30 4 29 165 8.8 0 9 8.8 06/17/2006 23:00:00 3.9 0.5 5.3 2.6 3.9 0.6 5.3 2.3 3.9 0.6 5.3 2.6 28 6 39 165 8.8 0 9 8.8 06/17/2006 23:10:00 4.4 0.4 5.3 3 4.4 0.4 5.3 3 4.4 0.4 5.3 3.4 30 4 29 165 8.8 0 9 8.8 06/17/2006 23:20:00 4 0.4 5.3 2.6 4 0.4 4.9 2.6 4.1 0.4 5.3 2.6 34 5 35 165 8.8 0 9 8.8 06/17/2006 23:30:00 3.8 0.5 4.9 2.6 3.8 0.5 5.3 2.6 3.8 0.5 5.3 2.6 36 7 35 165 8.8 0 9 8.8 06/17/2006 23:40:00 4.1 0.6 5.3 2.3 4 0.6 5.3 1.9 4 0.6 5.3 2.3 36 7 35 165 8.8 0 9 8.8 06/17/2006 23:50:00 3.9 0.6 5.3 2.3 3.8 0.6 5.3 2.3 3.8 0.5 5.3 1.9 36 7 41 165 8.9 0 9 8.8 06/18/2006 00:00:00 3.7 0.5 4.6 1.9 3.6 0.5 4.6 1.5 3.5 0.5 4.9 1.9 34 8 44 165 8.9 0 9 8.5 06/18/2006 00:10:00 3.1 0.5 4.6 1.9 2.9 0.5 4.2 1.9 3 0.5 4.2 1.5 34 7 43 165 8.9 0 9 8.5 06/18/2006 00:20:00 3.2 0.4 4.2 2.3 3.1 0.4 4.2 2.3 3.1 0.4 4.2 2.3 40 9 49 165 8.9 0 9 8.5 06/18/2006 00:30:00 3.3 0.5 4.9 2.3 3.3 0.5 4.9 1.9 3.2 0.5 4.6 1.9 41 8 48 165 8.9 0 9 8.5 06/18/2006 00:40:00 2.9 0.4 3.8 1.9 2.8 0.5 4.2 1.5 2.8 0.4 3.8 1.9 33 9 46 165 8.9 0 9 8.5 06/18/2006 00:50:00 2.7 0.3 3.4 1.9 2.7 0.4 3.4 1.9 2.7 0.3 3.4 1.9 39 7 39 165 8.9 0 9 8.5 06/18/2006 01:00:00 2.9 0.3 3.8 1.9 2.9 0.4 3.8 1.9 2.9 0.4 3.8 1.5 40 6 52 165 8.9 0 9 8.3 06/18/2006 01:10:00 2.9 0.3 3.8 1.9 2.8 0.3 3.8 1.9 2.8 0.4 4.2 1.9 31 5 41 165 8.9 0 9 8.5 06/18/2006 01:20:00 3.1 0.4 3.8 1.9 3 0.4 3.8 1.9 3.2 0.4 3.8 2.3 35 6 32 165 8.9 0 9 8.3 06/18/2006 01:30:00 2.8 0.5 4.2 1.5 2.7 0.5 4.2 1.5 2.8 0.5 4.2 1.5 38 7 60 165 8.9 0 9 8.3 06/18/2006 01:40:00 2.7 0.8 4.6 1.5 2.7 0.9 4.6 1.1 2.7 0.8 4.6 1.5 53 11 56 165 8.9 0 9 8.3 06/18/2006 01:50:00 3.9 0.5 4.9 2.6 4 0.5 5.3 2.6 3.9 0.5 4.9 2.3 72 7 75 165 8.9 0 9 8.5 06/18/2006 02:00:00 4.3 0.5 5.3 3 4.4 0.5 5.3 3 4.1 0.5 4.9 2.6 86 6 79 165 8.9 0 9 8.5 06/18/2006 02:10:00 4.5 0.3 5.3 3 4.7 0.4 5.3 3 4.3 0.4 5.3 3 99 5 95 165 8.9 0 9 8.5 06/18/2006 02:20:00 4.3 0.3 4.9 3 4.4 0.3 4.9 3 4.1 0.4 4.9 2.6 96 5 105 165 8.9 0 9 8.8 06/18/2006 02:30:00 4.5 0.4 5.3 3.4 4.7 0.4 5.7 3.4 4.3 0.5 5.3 2.6 87 4 95 165 9 0 9 9 06/18/2006 02:40:00 4.2 0.5 5.3 3 4.4 0.5 5.7 3 4.2 0.5 4.9 3 78 6 85 165 8.9 0 9 8.8 06/18/2006 02:50:00 3.8 0.6 5.3 2.6 4 0.6 5.3 2.6 3.8 0.5 4.9 2.6 78 7 83 165 9 0 9 9 06/18/2006 03:00:00 3.6 0.7 5.3 2.3 3.7 0.7 5.3 2.3 3.6 0.6 5.3 2.3 75 8 81 165 9 0 9.3 9 06/18/2006 03:10:00 3.2 0.5 4.6 1.9 3.2 0.6 4.6 1.9 3.2 0.5 4.6 1.5 63 9 83 165 9 0 9 8.8 06/18/2006 03:20:00 3.4 0.6 4.9 2.3 3.4 0.6 4.9 2.3 3.3 0.6 5.3 2.3 71 9 87 165 8.9 0 9 8.8 06/18/2006 03:30:00 4.1 0.7 6.1 2.6 4.1 0.8 6.1 2.6 4 0.7 5.7 2.3 76 7 77 165 8.9 0 9 8.8 06/18/2006 03:40:00 4.5 0.7 6.1 3 4.6 0.7 6.1 3 4.4 0.6 5.7 3 83 6 84 165 8.9 0 9 9 06/18/2006 03:50:00 4.2 0.7 5.7 2.6 4.3 0.7 6.1 2.6 4 0.7 5.7 2.6 81 6 85 165 8.9 0 9 8.8 06/18/2006 04:00:00 3.1 0.7 4.6 1.5 3.1 0.7 4.6 1.5 3 0.7 4.2 1.5 67 9 78 165 8.9 0 9 8.8 06/18/2006 04:10:00 3 0.6 4.6 1.9 3.1 0.6 4.6 1.9 2.9 0.6 4.6 1.5 65 8 63 165 8.9 0 9 8.8 06/18/2006 04:20:00 3 0.5 4.2 1.9 3.2 0.5 4.6 2.3 2.9 0.5 4.2 1.9 65 8 77 165 8.9 0 9 8.8 06/18/2006 04:30:00 2.5 0.6 3.8 1.1 2.5 0.7 3.8 0.7 2.4 0.6 3.8 1.1 53 9 63 165 8.9 0 9 8.8 06/18/2006 04:40:00 2.7 0.5 3.8 1.5 2.8 0.6 4.2 1.1 2.6 0.5 4.2 1.1 57 9 51 165 8.9 0 9 8.3 06/18/2006 04:50:00 3.3 0.6 4.6 1.9 3.3 0.6 4.6 1.5 3.2 0.7 4.9 1.9 59 8 54 165 8.9 0 9 8.3 06/18/2006 05:00:00 3.8 0.5 4.9 2.3 3.9 0.6 5.3 2.6 3.7 0.6 4.9 2.3 70 6 74 165 8.9 0 9.3 8.5 06/18/2006 05:10:00 3.9 0.5 4.9 3 4.1 0.5 5.3 3 3.9 0.5 5.3 2.6 75 8 78 165 8.9 0 9 8.5 06/18/2006 05:20:00 4.1 0.5 5.3 2.6 4.2 0.5 5.3 2.6 3.9 0.5 5.7 2.6 80 5 87 165 8.9 0 9 8.5 06/18/2006 05:30:00 3.8 0.6 4.9 2.3 3.9 0.6 5.3 2.3 3.7 0.5 5.3 2.3 77 6 83 165 8.9 0 9 8.5 06/18/2006 05:40:00 3.5 0.6 4.9 2.3 3.7 0.6 4.9 2.6 3.5 0.5 4.9 2.3 79 7 81 165 9 0 9 8.5 06/18/2006 05:50:00 3.7 0.6 5.3 2.3 3.8 0.6 5.3 2.3 3.5 0.5 4.9 2.3 84 8 80 165 9 0.1 9 8.5 06/18/2006 06:00:00 4.5 0.5 5.7 2.6 4.7 0.5 5.7 3 4.4 0.5 5.7 3 92 5 94 165 9 0 9.3 8.5 06/18/2006 06:10:00 4.3 0.6 5.3 2.6 4.5 0.6 5.7 2.6 4.1 0.5 5.3 2.6 95 7 98 165 8.9 0 9 8.5 06/18/2006 06:20:00 5 0.5 6.1 3 5.2 0.5 6.1 3.4 4.6 0.6 5.7 3 101 5 102 165 8.9 0 9 8.5 06/18/2006 06:30:00 5.4 0.3 6.1 3.8 5.5 0.3 6.1 4.2 5.1 0.5 6.1 3.8 108 4 110 165 8.9 0 9 8.5 06/18/2006 06:40:00 5.1 0.3 6.1 4.2 5.3 0.3 6.1 4.6 5 0.4 6.5 3.8 107 3 110 165 8.9 0 9 8.5 06/18/2006 06:50:00 5 0.3 5.7 3.8 5.1 0.3 5.7 3.8 4.7 0.4 5.7 3.4 111 4 111 165 9 0 9 8.5 06/18/2006 07:00:00 4.6 0.4 5.3 3 4.8 0.4 5.7 3.4 4.5 0.4 5.3 3 112 3 111 165 9 0 9.6 9 06/18/2006 07:10:00 4.7 0.3 5.7 3.8 4.8 0.3 5.7 4.2 4.6 0.3 5.7 3.4 119 3 119 165 9.1 0 9.3 9 06/18/2006 07:20:00 4.3 0.4 5.3 3 4.4 0.4 5.3 3 4.3 0.4 5.3 3 118 6 112 165 9.1 0 9.3 9 06/18/2006 07:30:00 4.2 0.5 5.3 3 4.2 0.5 5.3 3 4.1 0.4 5.3 3 126 9 128 165 9.1 0 9.3 9 06/18/2006 07:40:00 5.1 0.5 6.5 3.4 5.1 0.5 6.5 3.4 5.1 0.4 6.1 3.8 135 6 128 165 9.1 0 9.3 9 06/18/2006 07:50:00 5.2 0.5 6.5 3.8 5.3 0.5 6.5 3.8 5.1 0.6 6.8 3.4 131 5 129 165 8.9 0 9 8.8 06/18/2006 08:00:00 5.3 0.5 6.5 3.8 5.4 0.5 6.5 3.8 5.3 0.6 6.5 3.8 133 4 137 165 8.9 0 9.3 8.8 06/18/2006 08:10:00 5.1 0.5 6.1 3.8 5.2 0.5 6.1 3.8 5 0.5 6.1 3.8 133 5 129 165 9 0 9 8.8 06/18/2006 08:20:00 5 0.6 6.5 3.4 5 0.6 6.5 3.4 4.9 0.7 6.1 3.4 133 5 128 165 8.9 0 9 8.8 06/18/2006 08:30:00 4.7 0.4 5.7 3.8 4.7 0.4 5.7 3.8 4.7 0.4 6.1 3.4 130 4 124 165 8.9 0 9 8.8 06/18/2006 08:40:00 5 0.4 6.1 3.8 5.1 0.4 6.1 3.8 5 0.5 6.1 3.8 128 5 121 165 8.9 0 9 8.8 06/18/2006 08:50:00 5 0.4 6.1 3.8 5 0.5 6.1 3.4 4.9 0.4 6.1 3.8 132 7 130 165 8.9 0 9 8.8 06/18/2006 09:00:00 4.7 0.6 5.7 3 4.6 0.6 6.1 3 4.7 0.6 6.1 2.6 135 5 130 165 8.9 0 9.6 8.8 06/18/2006 09:10:00 5 0.6 6.1 3.4 5 0.6 6.1 3 5 0.5 6.1 3.8 134 5 134 165 8.9 0 9 8.5 06/18/2006 09:20:00 5.4 0.5 6.5 3.4 5.4 0.5 6.5 3.4 5.3 0.6 6.5 3.8 136 7 145 165 8.9 0 9 8.5 06/18/2006 09:30:00 5.1 0.5 6.1 3.8 5.1 0.5 6.5 3.8 5 0.5 6.5 3.4 136 4 138 165 8.9 0 9 8.5 06/18/2006 09:40:00 5.4 0.5 6.5 4.2 5.3 0.4 6.5 4.2 5.5 0.5 6.5 3.8 140 5 135 165 8.9 0 9.3 8.5 06/18/2006 09:50:00 5 0.4 6.1 3.4 5 0.4 6.1 3.4 4.9 0.5 5.7 3.4 136 6 136 165 9 0 9 8.8 06/18/2006 10:00:00 5 0.5 6.1 3.4 5.1 0.5 6.1 3.8 5 0.5 6.1 3.4 135 7 137 165 9 0 9 8.8 06/18/2006 10:10:00 5.2 0.4 5.7 3.8 5.2 0.4 6.1 3.4 5.1 0.4 6.1 3.8 132 5 128 165 9 0 9 8.5 06/18/2006 10:20:00 5.3 0.5 6.5 4.2 5.3 0.5 6.5 4.2 5.3 0.5 6.5 3.8 132 5 128 165 8.9 0 9 8.5 06/18/2006 10:30:00 4.7 0.4 5.7 3.8 4.7 0.4 6.1 3.8 4.7 0.5 5.7 3.4 131 5 131 165 9 0 9.3 8.8 06/18/2006 10:40:00 4.8 0.4 5.7 3.8 4.8 0.4 6.1 3.8 4.9 0.5 6.1 3 138 6 132 165 9.3 0 9.6 9 06/18/2006 10:50:00 5.2 0.4 6.5 4.2 5.2 0.4 6.1 4.2 5.2 0.4 6.5 4.2 136 7 128 165 9.2 0.1 9.6 9 06/18/2006 11:00:00 5.4 0.5 6.5 3.8 5.4 0.5 6.8 4.2 5.4 0.5 6.5 3.8 134 6 128 165 9.5 0 9.8 9 06/18/2006 11:10:00 5.6 0.4 6.8 4.6 5.7 0.5 7.2 4.6 5.7 0.5 7.2 4.6 136 6 142 165 9.6 0.1 10.1 9 06/18/2006 11:20:00 6.4 0.4 7.6 5.3 6.4 0.4 7.2 5.3 6.5 0.5 7.6 4.9 139 4 143 165 9.3 0.1 9.6 8.8 06/18/2006 11:30:00 7.3 0.5 8.4 5.7 7.2 0.5 8.4 5.7 7.3 0.6 9.1 5.3 138 3 138 165 9.3 0 9.8 8.8 06/18/2006 11:40:00 7.3 0.6 8.4 5.3 7.4 0.6 8.4 5.7 7.1 0.6 8.4 5.3 131 6 122 165 9.2 0.1 9.6 8.5 06/18/2006 11:50:00 7 0.5 8.4 5.3 6.9 0.5 8 5.3 7.1 0.6 8.4 5.3 138 8 139 165 9 0 9.3 8.8 06/18/2006 12:00:00 7.7 0.5 9.1 6.1 7.6 0.5 9.1 6.1 7.6 0.5 8.8 6.1 138 5 131 165 8.8 0 9 8.5 06/18/2006 12:10:00 7.1 0.6 8.4 5.7 7 0.6 8.8 5.7 7.1 0.8 8.8 4.9 137 6 143 165 8.6 0 9 8.5 06/18/2006 12:20:00 6.9 0.6 8.8 5.3 6.9 0.6 8.8 5.3 6.8 0.7 8.8 4.9 130 6 129 165 8.6 0 8.8 8.5 06/18/2006 12:30:00 6.6 0.5 8.4 4.9 6.6 0.6 8 4.9 6.6 0.5 7.6 5.3 137 7 149 165 8.8 0 9.3 8.5 06/18/2006 12:40:00 6.4 0.4 7.6 5.3 6.5 0.4 7.6 4.6 6.4 0.5 7.6 4.9 133 5 135 165 8.9 0 9 8.8 06/18/2006 12:50:00 6.6 0.5 7.6 5.3 6.7 0.5 7.6 5.3 6.6 0.5 7.6 5.3 130 4 121 165 8.9 0 9 8.8 06/18/2006 13:00:00 6.8 0.5 8.4 5.3 6.8 0.5 8.4 5.3 6.8 0.6 8.4 4.9 137 6 148 165 8.9 0 9 8.8 06/18/2006 13:10:00 6.6 0.8 8 4.6 6.7 0.8 8.4 4.2 6.7 0.8 8.8 4.2 134 6 126 165 9 0 9.3 8.8 06/18/2006 13:20:00 7.2 0.4 8.8 6.1 7.3 0.4 8.8 6.1 7.2 0.5 8 5.3 129 4 128 165 8.9 0 9 8.8 06/18/2006 13:30:00 7.4 0.6 9.1 5.3 7.5 0.6 8.8 5.3 7.2 0.7 8.8 5.3 132 5 126 165 8.9 0 9 8.8 06/18/2006 13:40:00 7.9 0.7 9.5 5.7 7.9 0.7 9.5 5.7 7.8 0.8 9.9 4.9 134 6 134 165 8.7 0 9.3 8.5 06/18/2006 13:50:00 8.5 0.8 10.3 6.8 8.5 0.7 10.3 6.8 8.4 0.9 10.7 6.5 136 7 141 165 8.7 0.1 9 8.5 06/18/2006 14:00:00 8.6 0.6 9.9 6.8 8.5 0.6 9.9 6.8 8.6 0.7 10.3 6.1 141 4 141 165 8.7 0 8.8 8.5 06/18/2006 14:10:00 7.5 0.5 8.8 6.5 7.5 0.5 8.8 6.1 7.5 0.6 9.1 4.9 140 5 138 165 8.7 0 8.8 8.5 06/18/2006 14:20:00 6.9 0.7 9.1 4.6 6.9 0.7 9.1 4.9 6.9 0.8 9.1 4.2 139 7 142 165 8.7 0 8.8 8.5 06/18/2006 14:30:00 6.8 0.5 8 4.9 6.8 0.5 8.4 4.9 6.8 0.6 8 4.9 137 6 146 165 8.6 0 9.3 8.3 06/18/2006 14:40:00 6.3 0.5 7.6 4.6 6.4 0.5 7.6 4.6 6.4 0.6 7.6 4.6 137 8 128 165 8.7 0 9 8.5 06/18/2006 14:50:00 6.4 0.6 8 4.9 6.4 0.6 8 4.6 6.5 0.6 8 4.9 142 5 142 165 8.6 0 9 8.5 06/18/2006 15:00:00 6.2 0.5 7.2 4.9 6.2 0.5 7.2 4.6 6.2 0.6 8 4.9 141 5 136 165 8.6 0 8.8 8.5 06/18/2006 15:10:00 6 0.5 7.6 4.6 6 0.5 7.2 4.6 6.1 0.5 7.6 4.9 141 3 140 165 8.7 0 9 8.5 06/18/2006 15:20:00 6.6 0.5 8.4 5.3 6.6 0.5 8.4 4.9 6.5 0.5 8 5.3 137 5 134 165 8.5 0 8.8 8.3 06/18/2006 15:30:00 6.8 0.5 8 5.3 6.7 0.4 8 5.3 6.8 0.5 8.4 5.3 141 5 147 165 8.5 0 8.8 8.3 06/18/2006 15:40:00 6.2 0.5 7.6 4.9 6.2 0.5 7.6 4.9 6.3 0.6 7.2 4.2 137 4 137 165 8.5 0 8.8 8.3 06/18/2006 15:50:00 5.6 0.5 7.2 3.8 5.6 0.5 6.8 3 5.6 0.5 6.8 4.2 136 7 123 165 8.5 0 8.8 8.3 06/18/2006 16:00:00 5.6 0.5 7.2 4.2 5.6 0.5 7.2 4.6 5.6 0.6 7.6 4.2 135 7 129 165 8.5 0 8.8 8.5 06/18/2006 16:10:00 5.9 0.4 7.2 4.6 5.9 0.4 7.2 4.9 5.9 0.5 7.2 4.6 135 6 143 165 8.5 0 9 8.5 06/18/2006 16:20:00 5.6 0.5 7.2 4.6 5.6 0.5 7.2 4.2 5.6 0.5 6.8 4.6 130 5 122 165 8.5 0 8.5 8.3 06/18/2006 16:30:00 5.6 0.4 6.5 4.9 5.6 0.4 6.8 4.6 5.6 0.4 6.8 4.9 131 6 119 165 8.5 0 8.5 8.3 06/18/2006 16:40:00 5.1 0.4 6.5 3.8 5.1 0.4 6.1 3.8 5.2 0.4 6.5 4.2 132 6 133 165 8.5 0 8.5 8.3 06/18/2006 16:50:00 5.1 0.5 6.1 4.2 5 0.5 6.1 3.8 5.1 0.5 6.1 3.8 137 6 133 165 8.5 0 8.5 8.5 06/18/2006 17:00:00 5 0.5 6.1 3.8 5 0.4 6.1 3.8 5 0.4 6.1 3.4 135 6 143 165 8.5 0 9 8.5 06/18/2006 17:10:00 4.3 0.5 5.7 3.4 4.3 0.5 5.7 3 4.2 0.6 5.7 3 132 7 127 165 8.6 0 8.8 8.5 06/18/2006 17:20:00 4.8 0.6 6.5 2.6 4.8 0.7 6.5 2.3 4.8 0.6 6.1 2.6 135 6 124 165 8.6 0 8.8 8.5 06/18/2006 17:30:00 5 0.5 6.5 3.4 5 0.5 6.1 3.4 4.9 0.6 6.5 3.4 128 6 136 165 8.5 0 8.5 8.5 06/18/2006 17:40:00 5.2 0.5 6.1 3.4 5.2 0.5 6.5 3 5.2 0.4 6.1 4.2 128 5 124 165 8.5 0 8.8 8.5 06/18/2006 17:50:00 4.8 0.6 5.7 2.3 4.8 0.6 5.7 2.6 4.8 0.5 5.7 3 124 4 125 165 8.7 0 8.8 8.5 06/18/2006 18:00:00 4.2 0.6 5.3 2.6 4.2 0.7 5.7 2.6 4.3 0.7 5.3 2.6 134 8 132 165 8.8 0 9 8.8 06/18/2006 18:10:00 4.8 0.6 6.1 3 4.8 0.6 6.5 3 4.9 0.6 6.5 3 132 7 133 165 8.7 0 9 8.5 06/18/2006 18:20:00 5.4 0.6 6.8 4.2 5.4 0.6 6.8 4.2 5.3 0.5 6.8 4.2 126 7 134 165 8.6 0 8.8 8.3 06/18/2006 18:30:00 4.7 0.5 5.7 3 4.8 0.5 5.7 3.4 4.6 0.5 5.7 3.4 114 8 116 165 8.5 0 8.8 8.3 06/18/2006 18:40:00 5.4 0.5 6.5 3 5.5 0.5 6.5 3.4 5.3 0.6 6.5 3.4 115 7 115 165 8.5 0.1 8.8 8 06/18/2006 18:50:00 5.5 0.5 6.8 4.2 5.5 0.5 7.2 4.2 5.4 0.5 6.8 3.8 120 6 122 165 8.5 0.1 8.5 8 06/18/2006 19:00:00 4.9 0.4 6.1 3.4 5 0.4 6.1 3.8 4.8 0.4 6.1 3.8 124 6 126 165 8.5 0.1 9 8 06/18/2006 19:10:00 4.5 0.6 5.7 3 4.7 0.6 6.1 3 4.5 0.6 6.1 3 118 7 114 165 8.4 0.1 8.5 7.8 06/18/2006 19:20:00 4.1 0.7 5.3 2.3 4.2 0.7 5.7 2.3 4.1 0.7 5.3 2.6 113 6 117 165 8.3 0 8.5 7.8 06/18/2006 19:30:00 4.2 0.5 5.3 2.6 4.3 0.5 5.3 2.6 4.1 0.5 4.9 2.6 106 5 101 165 8.4 0 8.5 7.8 06/18/2006 19:40:00 4.1 0.4 4.9 3 4.2 0.4 5.3 2.6 3.9 0.5 5.3 2.6 104 6 101 165 8.4 0 8.5 7.8 06/18/2006 19:50:00 4.8 0.5 5.7 3.4 4.9 0.5 5.7 3.4 4.6 0.5 5.7 3.4 95 5 98 165 8.4 0.1 8.5 7.8 06/18/2006 20:00:00 4.6 0.4 5.7 3.4 4.8 0.4 5.7 3.4 4.5 0.5 5.7 3 101 5 105 165 8.3 0 8.5 8 06/18/2006 20:10:00 4.5 0.5 5.7 3 4.7 0.5 5.7 3 4.4 0.6 5.7 2.6 105 5 118 165 8.3 0 8.5 7.8 06/18/2006 20:20:00 4.8 0.5 6.1 3.4 4.9 0.5 6.1 3.4 4.6 0.6 6.1 3 113 5 114 165 8.2 0 8.5 7.8 06/18/2006 20:30:00 4.3 0.5 5.3 3 4.4 0.5 5.3 3 4.2 0.6 5.3 2.6 108 5 110 165 8.2 0 8.3 7.8 06/18/2006 20:40:00 4.8 0.3 5.7 3.8 4.9 0.4 6.1 3.8 4.6 0.5 5.7 3 113 5 116 165 8.3 0 8.3 8.3 06/18/2006 20:50:00 4.8 0.4 5.7 3.4 4.9 0.5 5.7 3.4 4.5 0.6 5.7 2.6 114 6 116 165 8.3 0 8.3 8.3 06/18/2006 21:00:00 5.2 0.5 6.5 4.2 5.3 0.6 6.5 4.2 4.9 0.6 6.5 3.4 114 4 112 165 8.3 0 8.5 8.3 06/18/2006 21:10:00 5 0.6 6.5 3.4 5.2 0.6 6.8 3.4 4.7 0.6 6.5 3 115 5 113 165 8.3 0 8.5 8.3 06/18/2006 21:20:00 5.6 0.6 7.2 4.2 5.8 0.6 7.2 4.2 5.4 0.7 7.2 3.4 119 5 125 165 8.3 0 8.5 8.3 06/18/2006 21:30:00 6.2 0.6 7.6 4.6 6.2 0.6 7.6 4.6 6 0.6 7.2 4.2 124 5 131 165 8.4 0 8.5 8.3 06/18/2006 21:40:00 5.5 0.6 7.2 3.8 5.6 0.6 7.2 4.2 5.4 0.6 7.2 3.8 121 7 128 165 8.4 0 8.5 8.3 06/18/2006 21:50:00 4 0.8 6.1 2.3 4 0.9 6.1 2.3 3.9 0.9 6.1 1.9 108 8 110 165 8.3 0 8.5 8.3 06/18/2006 22:00:00 3.3 0.4 4.2 1.9 3.4 0.4 4.6 2.3 3.3 0.4 4.2 2.3 102 8 111 165 8.3 0 8.5 8.3 06/18/2006 22:10:00 4 0.4 5.7 3 4.1 0.4 5.7 3 3.9 0.4 5.3 3 121 5 119 165 8.3 0 8.3 8.3 06/18/2006 22:20:00 3.9 0.5 5.3 2.6 3.9 0.5 5.3 2.3 3.9 0.5 5.7 2.6 118 6 116 165 8.3 0 8.5 8.3 06/18/2006 22:30:00 4.3 0.5 5.3 3 4.3 0.5 5.7 3 4.4 0.5 5.7 3 127 7 130 165 8.1 0.1 8.3 8 06/18/2006 22:40:00 4.5 0.5 5.3 3.4 4.4 0.5 5.3 3.4 4.5 0.5 6.1 3 131 9 128 165 8 0 8.3 8 06/18/2006 22:50:00 4.1 0.5 5.3 3 4.1 0.5 5.7 2.6 4.2 0.5 5.7 3 133 6 126 165 8 0.1 8 7.3 06/18/2006 23:00:00 5 0.4 6.5 3.8 4.9 0.4 6.5 3.8 4.9 0.5 6.1 3.8 135 6 148 165 8 0.1 8 7.3 06/18/2006 23:10:00 5.3 0.4 6.5 4.2 5.3 0.4 6.5 4.6 5.3 0.5 6.1 4.2 139 6 128 165 8 0.1 8.3 7.5 06/18/2006 23:20:00 5.4 0.5 6.5 3.8 5.4 0.4 6.5 4.2 5.3 0.4 6.5 4.2 140 6 145 165 8 0 8.3 7.5 06/18/2006 23:30:00 5.5 0.4 6.5 4.6 5.5 0.4 6.5 4.6 5.5 0.5 6.8 4.2 142 3 139 165 8 0 8.3 7.5 06/18/2006 23:40:00 4.8 0.3 5.7 4.2 4.8 0.3 5.3 4.2 4.9 0.3 5.7 4.2 144 3 143 165 8 0.1 8.3 7.3 06/18/2006 23:50:00 3.9 0.4 4.9 3 3.8 0.4 4.6 3 4 0.4 4.9 2.6 137 5 145 165 7.9 0 8 7.8 06/19/2006 00:00:00 4.3 0.5 5.3 3.4 4.3 0.5 5.3 3 4.3 0.5 5.3 3 137 4 141 165 7.7 0 7.8 7.5 06/19/2006 00:10:00 5 0.3 5.7 4.2 5 0.3 5.7 4.2 5.1 0.3 6.1 4.2 144 6 146 165 7.7 0 7.8 7.5 06/19/2006 00:20:00 4.7 0.5 5.7 3.4 4.6 0.6 5.7 3.4 4.9 0.5 5.7 3.8 153 3 152 165 7.9 0 8 7.8 06/19/2006 00:30:00 4.3 0.3 4.9 3.4 4.2 0.3 4.9 3.4 4.5 0.3 5.3 3.4 153 3 155 165 7.8 0 8 7.8 06/19/2006 00:40:00 4.1 0.4 5.3 3 4 0.4 4.9 2.6 4.2 0.4 4.9 3 151 3 148 165 7.8 0 7.8 7.8 06/19/2006 00:50:00 3.2 0.3 4.2 2.6 3.1 0.3 3.8 2.3 3.3 0.3 4.2 2.6 152 3 144 165 7.8 0 7.8 7.8 06/19/2006 01:00:00 2.7 0.3 3.4 1.9 2.6 0.3 3.4 1.9 2.8 0.3 3.4 2.3 147 4 139 165 7.7 0 8 7.5 06/19/2006 01:10:00 2.5 0.4 3.4 1.5 2.4 0.4 3 1.5 2.7 0.3 3.4 1.9 142 4 147 165 7.5 0 7.8 7.5 06/19/2006 01:20:00 2.7 0.4 3.8 1.9 2.7 0.4 3.8 1.9 2.9 0.3 3.8 2.3 135 4 135 165 7.4 0 7.5 7.3 06/19/2006 01:30:00 3.5 0.4 4.2 2.6 3.5 0.4 4.2 2.3 3.7 0.4 4.6 2.6 132 5 133 165 7.4 0 7.5 7.5 06/19/2006 01:40:00 3.7 0.2 4.2 3 3.7 0.3 4.2 3 3.8 0.2 4.6 3 138 3 138 165 7.4 0 7.5 7.5 06/19/2006 01:50:00 3.3 0.3 3.8 2.6 3.1 0.3 3.8 2.3 3.3 0.3 4.2 2.6 140 3 145 165 7.4 0 7.5 7.5 06/19/2006 02:00:00 3.4 0.2 4.2 3 3.3 0.2 3.8 2.6 3.5 0.3 4.2 3 141 2 145 165 7.4 0 7.5 7.3 06/19/2006 02:10:00 3.6 0.3 4.6 3 3.5 0.3 4.2 2.6 3.6 0.3 4.6 2.6 139 6 126 165 7.3 0 7.5 7.3 06/19/2006 02:20:00 3.5 0.3 4.2 2.6 3.5 0.3 4.2 3 3.6 0.3 4.2 3 139 4 140 165 7.3 0 7.5 7.3 06/19/2006 02:30:00 3.1 0.2 3.8 2.3 3.2 0.2 3.8 2.6 3.3 0.3 3.8 2.6 131 4 133 165 7.3 0 7.3 7.3 06/19/2006 02:40:00 2.7 0.3 3.4 2.3 2.7 0.3 3.4 2.3 2.8 0.3 3.4 2.3 127 2 132 165 7.2 0 7.3 7.3 06/19/2006 02:50:00 2.6 0.3 3 2.3 2.6 0.3 3 2.3 2.8 0.2 3.4 2.3 129 3 128 165 7.1 0 7.3 7.3 06/19/2006 03:00:00 2.5 0.3 3.4 1.5 2.5 0.4 3.8 1.5 2.7 0.3 3.4 1.9 129 4 116 165 7.3 0 7.3 7.3 06/19/2006 03:10:00 2.2 0.3 3 1.5 2.3 0.4 3.4 1.5 2.4 0.3 3 1.9 118 5 116 165 7.3 0 7.5 7.3 06/19/2006 03:20:00 2.3 0.2 2.6 1.9 2.4 0.2 3 1.9 2.5 0.2 3 2.3 112 3 110 165 7.3 0 7.3 7.3 06/19/2006 03:30:00 3 0.4 4.2 2.3 3.1 0.4 4.2 2.3 3.1 0.5 4.2 1.9 108 5 105 165 7.3 0 7.3 7.3 06/19/2006 03:40:00 4.1 0.8 6.1 3 4.2 0.8 6.1 3 4 0.8 5.7 2.6 106 5 113 165 7.2 0 7.3 7.3 06/19/2006 03:50:00 5.1 0.6 6.5 3.8 5.2 0.6 6.5 3.8 4.9 0.7 6.1 3.4 113 4 112 165 7.2 0 7.3 7 06/19/2006 04:00:00 3.7 0.4 4.6 3 3.8 0.4 4.6 3 3.6 0.4 4.6 2.6 118 3 118 165 7.1 0 7.3 7.3 06/19/2006 04:10:00 3.9 0.5 4.9 2.3 4 0.5 4.9 2.3 3.8 0.5 5.3 2.6 104 6 102 165 7.3 0 7.3 7.3 06/19/2006 04:20:00 4.1 0.5 5.3 3 4.2 0.5 5.3 3 4 0.5 5.3 3 100 8 102 165 7.3 0 7.3 7.3 06/19/2006 04:30:00 4.4 0.3 4.9 3.8 4.5 0.3 5.3 3.8 4.4 0.3 5.3 3.4 91 2 94 165 7.2 0 7.3 7 06/19/2006 04:40:00 3.9 0.3 4.6 2.6 4 0.3 4.9 3 3.7 0.4 4.6 2.6 84 4 91 165 7.1 0 7.3 7 06/19/2006 04:50:00 3.5 0.6 4.6 1.9 3.6 0.6 4.9 1.9 3.5 0.5 4.9 1.9 80 8 86 165 7.1 0 7.3 7 06/19/2006 05:00:00 3.1 0.4 4.6 2.3 3.3 0.4 4.6 2.3 3.2 0.4 4.2 2.3 76 6 74 165 7.2 0 7.3 7.3 06/19/2006 05:10:00 3.5 0.5 4.2 1.9 3.6 0.5 4.2 1.9 3.5 0.6 4.6 1.9 67 5 68 165 7.3 0 7.3 7.3 06/19/2006 05:20:00 3.9 0.3 4.6 3 4 0.2 4.6 3 3.9 0.3 4.6 3 62 3 66 165 7.2 0 7.3 7.3 06/19/2006 05:30:00 3.3 0.4 4.6 2.3 3.4 0.4 4.6 1.9 3.2 0.4 4.2 1.9 60 6 56 165 7.3 0 7.5 7 06/19/2006 05:40:00 3 0.7 4.6 1.5 3.1 0.7 4.6 1.5 3.1 0.7 4.6 1.5 51 10 39 165 7.4 0 7.5 7.3 06/19/2006 05:50:00 3 0.5 4.2 1.9 3.1 0.6 4.2 1.9 3 0.6 4.2 1.5 54 7 54 165 7.4 0 7.5 7.3 06/19/2006 06:00:00 3.3 0.8 4.6 1.5 3.3 0.8 4.9 1.5 3.2 0.7 4.6 1.5 54 9 47 165 7.4 0 7.5 7.3 06/19/2006 06:10:00 3.3 0.7 4.9 1.5 3.4 0.8 4.9 1.1 3.3 0.6 4.9 1.9 58 9 64 165 7.5 0 7.5 7.3 06/19/2006 06:20:00 2.8 0.6 4.2 1.5 2.8 0.6 4.2 1.5 2.9 0.6 4.6 1.5 64 10 70 165 7.4 0 7.5 7.3 06/19/2006 06:30:00 3.6 0.7 4.9 1.9 3.7 0.8 4.9 1.9 3.7 0.7 5.7 1.9 51 10 35 165 7.4 0 7.8 7.5 06/19/2006 06:40:00 3.9 0.5 4.9 2.3 4 0.6 5.3 2.3 3.9 0.7 4.9 2.3 48 6 45 165 7.5 0 7.8 7.5 06/19/2006 06:50:00 3.4 0.8 4.9 1.9 3.5 0.8 4.9 1.9 3.5 0.8 5.3 0.7 46 12 47 165 7.6 0 7.8 7.5 06/19/2006 07:00:00 3.2 0.7 4.6 1.5 3.2 0.8 4.9 1.1 3.3 0.7 4.6 1.5 49 14 58 165 7.5 0 7.8 7.5 06/19/2006 07:10:00 3.8 0.8 5.3 1.1 3.7 0.8 5.3 0.7 3.7 0.7 5.3 1.9 43 13 31 165 7.6 0 7.8 7.5 06/19/2006 07:20:00 3.6 0.6 4.9 2.3 3.6 0.7 4.9 1.9 3.7 0.7 5.3 1.9 48 11 53 165 7.6 0 7.8 7.5 06/19/2006 07:30:00 4.6 0.6 5.7 3 4.5 0.6 5.7 3 4.4 0.8 6.5 2.6 33 9 31 165 7.6 0 7.8 7.5 06/19/2006 07:40:00 3.9 0.7 5.3 2.6 3.8 0.7 5.7 2.3 3.9 0.7 5.7 2.3 37 13 31 165 7.7 0 7.8 7.5 06/19/2006 07:50:00 4.8 0.8 7.2 3 4.7 0.8 6.8 2.6 4.7 0.9 6.5 2.6 29 9 26 165 7.6 0 7.8 7.5 06/19/2006 08:00:00 4.7 0.8 6.1 2.6 4.4 0.8 6.1 2.3 4.6 0.7 6.1 2.6 24 11 24 165 7.8 0 7.8 7.5 06/19/2006 08:10:00 5.4 1 7.6 3 5.1 1.1 7.2 2.3 5.3 1 7.6 2.6 21 8 25 165 7.8 0 8 7.5 06/19/2006 08:20:00 5.6 0.7 7.2 3.8 5.3 0.8 6.8 3.4 5.4 0.8 6.8 3 20 7 22 165 7.8 0 8 7.8 06/19/2006 08:30:00 5.7 0.7 7.2 3.8 5.4 0.8 6.8 3.4 5.5 0.7 8 3.8 21 8 25 165 7.8 0 8 7.8 06/19/2006 08:40:00 5.4 0.6 6.8 3.4 4.8 0.8 6.5 2.6 5.3 0.6 6.8 3.4 15 8 18 165 7.8 0 8 7.8 06/19/2006 08:50:00 5.3 0.7 6.8 3.4 4.9 0.9 6.8 2.6 5.1 0.8 6.8 3.4 19 9 22 165 7.8 0 8 7.8 06/19/2006 09:00:00 5.4 0.7 6.8 3.4 5.1 0.7 6.8 3.4 5.1 0.8 6.8 3 21 8 26 165 7.8 0 8 7.8 06/19/2006 09:10:00 5.6 0.6 7.2 3.8 5.1 0.7 7.2 2.6 5.5 0.6 7.2 3.8 18 7 15 165 7.8 0 8 7.8 06/19/2006 09:20:00 5.2 0.7 6.8 3.4 4.9 0.7 6.5 2.6 5 0.9 6.8 2.6 22 7 21 165 8 0 8 7.8 06/19/2006 09:30:00 5.3 0.8 7.2 3.4 5 0.9 7.2 2.6 5.2 0.8 6.8 3.4 21 8 18 165 8.1 0 8.3 8 06/19/2006 09:40:00 5.7 0.7 7.2 3.8 5.5 0.7 7.2 3 5.6 0.7 6.8 3.8 23 7 16 165 8 0 8.3 8 06/19/2006 09:50:00 5.7 0.7 6.8 3.8 5.3 0.9 6.8 2.3 5.6 0.8 7.6 3.4 22 7 23 165 8.1 0 8.3 8 06/19/2006 10:00:00 6 0.7 7.6 3.8 5.6 0.9 7.2 3 6.1 0.7 7.6 4.2 19 7 22 165 8.3 0 8.5 7.8 06/19/2006 10:10:00 6.4 0.6 7.6 4.6 6 0.8 7.6 2.3 6.2 0.8 8 4.6 22 7 18 165 8.4 0 8.5 8.3 06/19/2006 10:20:00 6.3 0.6 7.6 4.6 6 0.7 7.6 3.8 6.3 0.6 8 4.6 20 5 25 165 8.3 0 8.5 8.3 06/19/2006 10:30:00 6.4 0.6 7.6 4.2 5.7 0.8 7.2 3 6.3 0.7 8 4.6 16 7 4 165 8.5 0.1 8.8 8.3 06/19/2006 10:40:00 6.7 0.6 8 5.3 6.3 0.7 7.6 3.8 6.5 0.8 8 4.6 20 6 8 165 8.7 0 8.8 8.5 06/19/2006 10:50:00 6.8 0.8 8.8 4.6 6.4 1 8.8 3.8 6.7 0.9 8.8 4.9 19 8 11 165 8.7 0 8.8 8.5 06/19/2006 11:00:00 7.1 0.9 9.1 3.8 6.8 1 9.1 3 7 1 9.1 4.2 21 7 26 165 8.9 0.1 9 8.8 06/19/2006 11:10:00 6.9 0.9 8.8 4.2 6.6 1 8.8 3.8 6.6 1 8.8 4.6 23 7 28 165 9 0 9.3 9 06/19/2006 11:20:00 6.8 0.9 8.8 4.6 6.6 1 8.8 3 6.8 1 9.1 4.6 24 8 11 165 8.8 0 9 8.5 06/19/2006 11:30:00 6.6 0.7 8.4 4.6 6.5 0.7 8 4.2 6.5 0.7 8.8 4.2 25 8 27 165 8.9 0 9 8.8 06/19/2006 11:40:00 7 0.7 8.8 4.9 6.8 0.9 8.4 4.2 6.9 0.8 8.8 4.6 24 8 19 165 8.9 0 9 8.8 06/19/2006 11:50:00 7 0.8 8.8 4.9 6.7 0.9 8.4 3.8 7 0.8 8.4 4.6 23 7 31 165 8.9 0 9 8.8 06/19/2006 12:00:00 6.1 1 8.4 3.4 5.8 1.1 8 3 6.1 1 8 3.8 23 9 31 165 8.9 0 9 8.8 06/19/2006 12:10:00 6.4 0.7 8.4 4.6 6.2 0.8 8.4 3.8 6.4 0.8 8.4 4.6 23 7 35 165 8.9 0 9 8.8 06/19/2006 12:20:00 6.7 0.7 8.8 3.8 6.5 0.8 8 3.8 6.7 0.7 8.8 4.9 23 6 5 165 8.8 0 9 8.5 06/19/2006 12:30:00 6.5 0.8 8.4 3.8 6.3 0.9 8.4 3.4 6.5 0.8 8.8 4.2 24 7 23 165 9 0 9.3 8.8 06/19/2006 12:40:00 6.6 0.7 8.4 4.2 6.4 0.8 8 4.2 6.5 0.8 8.4 3.8 23 7 21 165 9.1 0 9.3 8.8 06/19/2006 12:50:00 6.4 0.8 8 3.8 6.1 0.9 8 3.4 6.3 0.8 8.4 4.2 22 6 26 165 9.1 0 9.3 8.8 06/19/2006 13:00:00 6.7 0.6 8.4 4.2 6.4 0.7 8 3.8 6.6 0.7 8.4 4.9 22 6 24 165 9 0 9.6 8.8 06/19/2006 13:10:00 7.1 0.7 8.8 4.6 6.9 0.8 8.4 4.6 6.9 0.9 8.8 4.9 23 7 18 165 9.1 0 9.3 8.8 06/19/2006 13:20:00 7.2 0.9 9.1 4.6 6.8 1 9.1 4.2 7.2 1 9.1 4.6 20 8 16 165 9.3 0 9.6 9 06/19/2006 13:30:00 7 0.7 9.1 5.3 6.7 0.8 8.8 4.2 7.1 0.7 9.1 4.9 19 7 20 165 9.1 0.1 9.8 8.8 06/19/2006 13:40:00 7 0.9 9.1 4.6 6.7 1 8.8 3.4 7 0.9 9.1 4.6 21 7 25 165 9 0 9 8.8 06/19/2006 13:50:00 7.1 0.8 8.8 3.8 6.7 1 8.8 3.8 7 0.9 8.8 4.6 20 6 17 165 9.2 0 9.3 9 06/19/2006 14:00:00 6.9 0.6 8 4.9 6.8 0.7 8 3.4 6.8 0.7 8.4 4.9 22 5 23 165 9.2 0 9.6 9 06/19/2006 14:10:00 5.9 0.9 8.4 3.8 5.5 0.9 8.4 3.4 6 0.9 8 3.4 19 9 28 165 9.4 0.1 9.6 9 06/19/2006 14:20:00 6.8 0.7 8.4 4.2 6.5 0.9 8 3.4 6.9 0.8 8.4 4.9 18 6 21 165 9.2 0.1 9.3 8.5 06/19/2006 14:30:00 5.8 0.7 7.6 3.8 5.7 0.8 7.2 3 6 0.7 7.2 3.8 23 7 29 165 9.2 0.1 9.6 8.8 06/19/2006 14:40:00 5.5 0.6 6.8 3.8 5.4 0.7 6.8 3.8 5.5 0.7 6.8 3 25 7 22 165 9 0.3 9.6 8.3 06/19/2006 14:50:00 5.2 0.5 6.5 3.8 5.3 0.6 6.5 3.8 5.3 0.7 6.5 3.4 30 6 31 165 8.7 0 9 8 06/19/2006 15:00:00 5.2 0.8 7.2 3 5.2 0.8 6.8 2.3 5.3 0.8 6.8 3.4 28 8 31 165 8.8 0 9 8.5 06/19/2006 15:10:00 5.3 0.8 6.8 3 5.4 0.9 6.8 3 5.4 0.8 7.2 3 31 9 28 165 8.9 0 9 8.5 06/19/2006 15:20:00 4.7 0.9 6.5 2.6 4.7 0.9 6.8 2.6 4.9 0.8 6.8 2.6 30 11 36 165 8.7 0 9 8.3 06/19/2006 15:30:00 4.1 0.9 6.5 1.5 4.1 0.9 6.1 1.5 4.3 0.8 6.1 2.6 29 11 23 165 8.9 0 9 8.8 06/19/2006 15:40:00 4.1 0.6 5.7 2.6 4.1 0.6 5.7 1.5 4.1 0.6 5.7 2.3 26 9 36 165 9 0 9.3 8.8 06/19/2006 15:50:00 4.2 0.7 5.7 2.6 4.1 0.7 5.7 2.3 4.3 0.7 5.7 2.6 28 11 33 165 9 0 9.3 8.8 06/19/2006 16:00:00 4.3 0.6 5.7 2.6 4.2 0.6 5.7 3 4.3 0.6 5.7 2.6 31 9 32 165 8.6 0.1 8.8 8.5 06/19/2006 16:10:00 4.2 1.1 6.5 2.3 4.2 1.1 6.8 2.3 4.1 1 6.5 2.3 54 12 68 165 8.5 0 8.8 8.5 06/19/2006 16:20:00 4.9 0.8 6.8 2.6 5.1 0.9 7.2 2.6 5 0.8 6.8 2.6 64 9 79 165 8.7 0.1 9 8.5 06/19/2006 16:30:00 4.8 0.9 7.2 2.3 4.9 1 7.2 2.6 4.7 0.8 6.5 3 61 11 61 165 8.8 0 9 8.5 06/19/2006 16:40:00 4.7 0.7 6.5 2.6 4.8 0.7 6.5 3 4.6 0.7 6.5 3 71 11 75 165 8.7 0 9 8.5 06/19/2006 16:50:00 5.3 0.9 7.6 3 5.5 1 7.6 3 5.4 0.9 7.2 3 84 10 80 165 8.6 0 8.8 8.5 06/19/2006 17:00:00 5.9 0.8 7.6 3.4 6 0.8 8.4 3.8 5.8 0.8 8.4 3.8 75 11 82 165 8.6 0 9 8.3 06/19/2006 17:10:00 6 0.9 8 3.4 6.2 0.9 8.4 3.8 5.9 0.8 8 4.2 74 8 84 165 8.6 0 8.8 8.3 06/19/2006 17:20:00 5.3 1 7.6 3 5.4 1 8 3 5.2 0.8 8 3.4 65 12 58 165 8.5 0.1 8.8 8 06/19/2006 17:30:00 5.6 1.3 8 3 5.7 1.4 8.4 3 5.5 1.2 8.4 3 57 9 57 165 8.4 0 8.5 8 06/19/2006 17:40:00 6 1.1 8.8 3.4 6 1.2 9.1 3 5.8 1.1 8.4 3.4 53 13 52 165 8.4 0 8.5 8 06/19/2006 17:50:00 7.3 1.1 9.5 4.2 7.4 1.1 9.9 4.2 7 1.1 9.5 4.2 53 8 41 165 8.5 0 8.5 8 06/19/2006 18:00:00 5.3 1 8.4 3 5.3 1 8.8 3 5.1 0.9 8.4 2.6 51 13 52 165 8.5 0 8.8 8.3 06/19/2006 18:10:00 5.7 1.1 8.8 3 5.7 1.1 8.8 3 5.6 1 8.8 3 39 10 39 165 8.5 0 8.8 8.3 06/19/2006 18:20:00 6.2 1 9.5 3.8 6.2 1 9.1 3.8 6 1 8.8 3.8 36 9 16 165 8.5 0.1 8.5 8 06/19/2006 18:30:00 5.3 1.1 9.1 3.4 5.3 1.1 8.8 3.4 5.3 1.1 8.4 3 45 11 20 165 8.5 0.1 8.8 8 06/19/2006 18:40:00 6.2 1.3 10.3 2.6 6.3 1.4 10.3 2.6 5.9 1.3 9.9 3 56 9 63 165 8.5 0 8.8 8.3 06/19/2006 18:50:00 5.9 1.1 8.8 3.4 6 1.1 8.8 3.8 5.8 1 8.4 3.4 71 12 61 165 8.5 0.1 8.5 8 06/19/2006 19:00:00 5.9 1 8.4 3.8 6.1 1 8.4 3.8 5.8 1 8.8 3.8 76 11 84 165 8.3 0 8.5 7.8 06/19/2006 19:10:00 6.9 1.2 9.9 4.2 7.1 1.2 10.3 4.6 6.8 1.1 9.5 4.2 75 10 84 165 8 0.1 8.3 7.5 06/19/2006 19:20:00 6.5 1.2 9.5 4.2 6.6 1.2 9.5 4.2 6.3 1.1 8.8 3.8 63 9 63 165 8.1 0 8.5 7.5 06/19/2006 19:30:00 6.8 1.4 10.3 4.2 6.8 1.4 10.3 4.2 6.5 1.3 9.9 3.8 55 13 53 165 8.1 0.1 8.3 8 06/19/2006 19:40:00 6.8 2 10.7 3.4 6.9 2.1 11.5 3.4 6.8 1.9 10.7 3.4 53 10 61 165 7.9 0 8.3 7.8 06/19/2006 19:50:00 5.1 1 7.6 2.3 5 1 7.6 2.3 5 0.9 7.2 2.3 39 12 57 165 8.2 0 8.5 8 06/19/2006 20:00:00 7.3 1.1 9.9 4.6 7.1 1.2 9.9 4.6 7.2 1.1 9.9 4.6 25 9 14 165 8.3 0 8.5 8.3 06/19/2006 20:10:00 7.2 1.2 9.9 3.8 7.1 1.2 9.5 3.8 7 1.1 9.9 4.6 33 11 35 165 8.3 0 8.5 8.3 06/19/2006 20:20:00 6 1.2 9.1 3.8 6 1.2 9.1 3.8 5.7 1.2 8.8 3 47 12 44 165 8.3 0 8.5 8.3 06/19/2006 20:30:00 7.2 1.2 9.9 3.8 7.3 1.2 9.9 3.8 7 1.1 9.5 4.2 52 9 46 165 8.2 0 8.5 8.3 06/19/2006 20:40:00 6.6 1.3 9.1 3.8 6.6 1.3 9.5 3.4 6.4 1.2 9.1 3.8 43 8 50 165 8.2 0 8.3 8 06/19/2006 20:50:00 5.7 1.3 8.8 3 5.7 1.3 8.4 3 5.5 1.1 8.4 3 51 11 50 165 8.3 0 8.3 8.3 06/19/2006 21:00:00 5.4 1 8.8 2.6 5.4 1 8.8 3 5.3 1 9.1 3.4 42 9 39 165 8.3 0 8.8 8.3 06/19/2006 21:10:00 6.4 1.2 9.5 3.4 6.3 1.2 9.5 3.4 6.3 1.1 9.5 4.2 34 11 10 165 8.3 0 8.5 8.3 06/19/2006 21:20:00 8.2 1.4 12.2 4.9 7.8 1.5 11.5 4.6 7.6 1.3 11.1 4.9 22 10 16 165 8.3 0 8.5 8.3 06/19/2006 21:30:00 8.6 1.3 12.6 5.3 8.2 1.3 12.2 4.9 8.2 1.3 12.6 4.9 20 9 11 165 8.3 0 8.5 8.3 06/19/2006 21:40:00 8.8 1.3 12.2 5.3 8.5 1.3 11.5 4.9 8.3 1.4 12.2 4.9 24 10 14 165 8.3 0 8.5 7.8 06/19/2006 21:50:00 7.1 1.3 10.7 3.8 6.9 1.3 10.7 3.8 6.7 1.2 9.5 4.2 31 11 34 165 8.4 0 8.5 7.8 06/19/2006 22:00:00 8.4 1.9 13 4.6 8.6 2 13.3 4.9 8.2 1.8 12.2 4.6 63 15 74 165 8.1 0.2 8.8 7.5 06/19/2006 22:10:00 8 1.2 11.5 4.9 8.2 1.3 11.8 4.9 7.7 1.2 11.5 4.6 65 10 63 165 8 0.1 8.3 7.5 06/19/2006 22:20:00 7.7 1.3 10.7 4.2 7.9 1.3 11.5 4.2 7.7 1.2 10.3 4.9 64 8 58 165 8 0.1 8.3 7.5 06/19/2006 22:30:00 7.8 1.4 11.1 3.8 7.9 1.5 11.5 4.2 7.5 1.3 10.3 3.8 60 10 52 165 8 0.1 8.3 7.5 06/19/2006 22:40:00 8.3 1.3 11.8 5.3 8.5 1.4 12.2 5.3 8 1.3 11.5 4.6 74 11 80 165 7.7 0.2 8 7.5 06/19/2006 22:50:00 7.7 1.2 11.5 4.6 7.9 1.2 11.1 4.6 7.5 1.1 10.3 4.6 68 9 54 165 7.7 0 7.8 7.5 06/19/2006 23:00:00 7.1 1.1 9.9 4.2 7.3 1.2 10.3 4.2 6.9 1 9.1 4.6 59 9 46 165 7.7 0 8 7.5 06/19/2006 23:10:00 6.7 1.2 9.5 4.2 6.9 1.2 9.9 4.2 6.7 1.1 9.1 4.2 64 10 66 165 7.6 0 7.8 7.5 06/19/2006 23:20:00 4.5 0.9 6.8 2.3 4.7 0.9 6.8 2.6 4.7 0.8 6.5 3 66 9 70 165 7.5 0 7.8 7.5 06/19/2006 23:30:00 6.7 0.9 9.1 4.6 7 1 9.5 4.6 6.7 1 9.1 4.6 79 8 84 165 7.4 0 7.8 7.3 06/19/2006 23:40:00 7 1.2 10.3 4.9 7.2 1.2 10.7 4.9 6.8 1.2 9.9 4.6 79 9 74 165 7.4 0 7.5 7.3 06/19/2006 23:50:00 7.7 0.9 9.9 5.3 8 1 10.3 5.3 7.4 0.9 10.3 5.3 78 5 81 165 7.3 0 7.5 7.3 06/20/2006 00:00:00 7.3 0.8 9.5 5.3 7.6 0.8 10.3 5.3 7.1 0.8 9.1 4.2 83 7 81 165 7.4 0 7.8 7.3 06/20/2006 00:10:00 8.2 0.5 9.1 6.5 8.5 0.5 9.5 6.1 7.9 0.6 9.5 5.7 93 7 81 165 7.4 0 7.5 7.3 06/20/2006 00:20:00 8.1 0.5 9.5 6.5 8.4 0.6 9.5 6.1 7.8 0.6 9.5 5.7 107 6 110 165 7.4 0 7.5 7.3 06/20/2006 00:30:00 8.2 0.6 9.9 5.7 8.4 0.7 9.9 5.7 8 0.7 9.9 5.7 118 9 124 165 7.4 0 7.5 7.3 06/20/2006 00:40:00 7.3 1 9.9 4.6 7.5 1 9.9 4.2 7.2 1 9.5 4.9 124 8 119 165 7.4 0 7.5 7.3 06/20/2006 00:50:00 7.1 0.7 9.1 5.7 7.2 0.7 9.5 5.3 7 0.8 9.5 4.6 132 8 136 165 7.3 0 7.3 7.3 06/20/2006 01:00:00 6.1 0.6 7.6 4.6 6.2 0.6 7.6 4.9 6.1 0.6 7.6 4.6 135 6 128 165 7.2 0 7.8 7 06/20/2006 01:10:00 5.1 1 7.2 2.3 5.2 1 7.2 2.6 5 1 6.8 1.9 133 7 136 165 7 0 7.3 7 06/20/2006 01:20:00 4.3 0.8 6.1 3 4.4 0.8 6.1 3 4.3 0.8 6.5 2.6 118 11 118 165 6.7 0 7 6.7 06/20/2006 01:30:00 5.3 1.1 8 3 5.4 1.2 8.4 2.6 5.1 1.1 7.6 2.6 122 11 121 165 6.9 0 7 6.7 06/20/2006 01:40:00 3.7 0.6 5.3 2.3 3.7 0.6 4.9 2.3 3.7 0.5 4.9 2.6 127 6 139 165 6.8 0 7 6.7 06/20/2006 01:50:00 3.2 0.5 4.6 2.3 3.2 0.5 4.6 2.3 3.2 0.5 4.2 1.9 132 6 135 165 6.7 0 7 6.7 06/20/2006 02:00:00 2.8 0.7 4.6 1.5 2.9 0.7 4.6 1.1 2.7 0.8 4.6 1.1 117 15 126 165 6.7 0 7 6.7 06/20/2006 02:10:00 3.9 1.3 6.1 1.1 4.1 1.4 6.5 1.1 3.7 1.3 6.1 1.5 98 10 87 165 6.5 0 6.7 6.2 06/20/2006 02:20:00 4 0.4 5.3 3 4.3 0.4 5.3 3.4 4.2 0.4 5.3 3 90 5 94 165 6.4 0 6.7 6.2 06/20/2006 02:30:00 4 0.3 4.9 3 4.2 0.3 4.9 3.4 4 0.4 5.3 3 101 8 97 165 6.5 0 6.7 6.2 06/20/2006 02:40:00 3.6 0.5 5.3 2.3 3.8 0.5 5.3 2.3 3.6 0.6 5.3 1.9 109 10 93 165 6.5 0 6.7 6.2 06/20/2006 02:50:00 3.3 0.5 4.2 2.3 3.4 0.5 4.6 2.3 3.2 0.6 4.6 1.9 113 7 123 165 6.4 0 6.7 6.2 06/20/2006 03:00:00 4.1 0.4 4.9 3 4.3 0.4 4.9 3 4.1 0.4 4.9 3 104 3 105 165 6.4 0 7 6.2 06/20/2006 03:10:00 4.5 0.3 5.3 3.8 4.7 0.3 5.7 4.2 4.5 0.4 5.3 3.4 96 5 99 165 6.4 0 6.7 6.2 06/20/2006 03:20:00 4.3 0.3 4.9 3.8 4.5 0.3 5.3 4.2 4.4 0.3 4.9 3.4 84 3 83 165 6.4 0 6.5 6.2 06/20/2006 03:30:00 4.2 0.2 4.9 3.8 4.4 0.2 4.9 3.8 4.4 0.3 4.9 3.4 93 3 91 165 6.3 0 6.5 6.2 06/20/2006 03:40:00 4.6 0.4 5.3 3.8 4.8 0.4 5.7 4.2 4.7 0.4 5.3 3.8 91 2 89 165 6.3 0 6.5 6.2 06/20/2006 03:50:00 4.7 0.2 5.3 4.2 4.9 0.2 5.7 4.2 4.7 0.4 5.3 3.8 96 3 93 165 6.4 0 6.7 6.2 06/20/2006 04:00:00 4.8 0.3 5.3 3.8 5 0.3 5.7 3.8 4.6 0.4 5.7 3 100 3 102 165 6.4 0 6.7 6.2 06/20/2006 04:10:00 4.2 0.4 4.9 3.4 4.4 0.4 5.3 3.4 4.2 0.4 4.9 3 91 5 96 165 6.5 0 6.7 6.2 06/20/2006 04:20:00 2.8 0.6 4.2 1.5 3 0.7 4.2 1.5 2.9 0.5 3.8 1.5 74 13 87 165 6.6 0 6.7 6.2 06/20/2006 04:30:00 2 0.4 2.6 1.1 2 0.4 3 0.7 2.3 0.4 3 1.1 32 10 42 165 6.5 0 6.7 6.2 06/20/2006 04:40:00 1.4 0.5 2.6 0.4 1.4 0.5 3 0.4 1.8 0.4 3 1.1 58 10 65 165 6.5 0 6.7 6.2 06/20/2006 04:50:00 1.8 0.6 3 0.7 1.8 0.6 3 0.7 2.1 0.5 3.4 1.1 34 16 30 165 6.6 0 6.7 6.5 06/20/2006 05:00:00 1.7 0.4 2.6 0.4 1.7 0.4 2.6 0.4 2.1 0.4 3 1.1 46 16 18 165 6.6 0 7 6.5 06/20/2006 05:10:00 1.4 0.4 2.3 0.4 1.3 0.4 2.3 0.4 1.7 0.4 2.6 0.7 68 10 81 165 6.6 0 6.7 6.5 06/20/2006 05:20:00 1.9 0.4 3 1.1 1.9 0.4 3 1.1 2.1 0.4 3.4 1.5 63 10 73 165 6.7 0 6.7 6.5 06/20/2006 05:30:00 1.9 0.6 3 0.7 2 0.6 3.4 0.7 2.2 0.6 3.4 1.1 73 10 87 165 6.7 0 7 6.7 06/20/2006 05:40:00 2.1 0.5 3 0.7 2.3 0.5 3.4 0.7 2.5 0.5 3.4 1.1 70 9 78 165 6.9 0 7.3 6.7 06/20/2006 05:50:00 2.5 0.6 3.8 0.7 2.5 0.7 4.2 0.4 2.7 0.6 4.2 0.4 77 13 81 165 7.1 0 7.3 7 06/20/2006 06:00:00 2.5 0.6 3.8 0.7 2.6 0.7 4.2 1.1 2.8 0.6 4.2 1.5 79 12 90 165 7.3 0 7.5 7 06/20/2006 06:10:00 2.5 0.6 3.8 1.1 2.6 0.6 3.8 1.1 2.6 0.6 3.8 1.1 84 10 91 165 7.3 0 7.5 7 06/20/2006 06:20:00 3.1 0.4 3.8 1.9 3.2 0.4 3.8 1.9 3.2 0.4 4.2 1.9 92 6 89 165 7.4 0.2 8 7 06/20/2006 06:30:00 1.8 0.4 3 0.7 1.7 0.5 3 0.4 1.9 0.5 3 0.7 72 17 99 165 7.9 0.1 8.3 7.5 06/20/2006 06:40:00 1.1 0.5 2.3 0.4 0.9 0.5 2.3 0.4 1.1 0.6 2.6 0.4 90 32 66 165 8.7 0.4 9.3 7.8 06/20/2006 06:50:00 1.5 0.6 3 0.4 1.5 0.6 3 0.4 1.6 0.6 3 0.4 107 26 111 165 8.9 0.2 9.3 8 06/20/2006 07:00:00 0.9 0.5 2.3 0.4 0.8 0.5 2.3 0.4 0.9 0.5 2.6 0.4 89 27 114 165 8.3 0.3 8.8 7.5 06/20/2006 07:10:00 1.2 0.8 3.4 0.4 1 0.8 3.4 0.4 1.2 0.9 3.4 0.4 97 39 139 165 8.3 0.1 9 7.8 06/20/2006 07:20:00 2.7 0.8 4.6 1.1 2.6 0.8 4.2 0.4 2.7 0.6 4.2 1.1 123 10 122 165 8 0.2 8.3 7.3 06/20/2006 07:30:00 3.3 0.5 4.6 1.9 3.3 0.5 4.9 1.9 3.5 0.5 4.6 1.9 117 7 121 165 7.8 0.2 8.3 7.3 06/20/2006 07:40:00 3.1 0.6 4.6 1.5 3 0.6 4.6 1.5 3.2 0.6 4.9 1.9 115 10 89 165 8.3 0.2 8.8 7.8 06/20/2006 07:50:00 2.9 0.6 4.6 1.5 2.8 0.6 4.6 1.5 3 0.5 4.6 1.5 114 10 121 165 8.5 0.3 9 7.8 06/20/2006 08:00:00 2.7 0.6 4.2 1.1 2.7 0.6 4.2 1.1 2.9 0.5 4.2 1.1 115 8 116 165 8.3 0.1 8.8 8 06/20/2006 08:10:00 2.4 0.4 3.4 1.5 2.3 0.4 3.4 1.5 2.6 0.4 3.4 1.9 110 7 102 165 7.8 0.2 8.3 7.3 06/20/2006 08:20:00 1.9 0.6 3 0.4 1.8 0.6 3.4 0.4 2.1 0.6 3.4 0.4 93 18 102 165 7.6 0.2 7.8 7.3 06/20/2006 08:30:00 1.7 0.5 3 0.4 1.5 0.7 3.4 0.4 1.8 0.5 3 0.7 66 18 39 165 7.7 0 8 7.3 06/20/2006 08:40:00 1.9 0.5 3 0.4 1.7 0.6 3 0.4 2.1 0.5 3 0.7 71 23 72 165 7.6 0 8.3 7.3 06/20/2006 08:50:00 1.9 0.7 3.8 0.4 1.7 0.8 3.8 0.4 2.1 0.6 3.8 0.7 84 17 102 165 7.5 0 8 7.3 06/20/2006 09:00:00 2.4 0.7 4.2 0.4 2.3 0.8 4.2 0.4 2.6 0.6 3.8 0.7 104 10 114 165 7.8 0.1 8 7.3 06/20/2006 09:10:00 3.2 0.6 4.6 1.9 3.2 0.6 4.6 1.1 3.2 0.5 4.6 1.9 103 10 100 165 7.8 0 8 7.8 06/20/2006 09:20:00 2.7 0.5 4.2 0.7 2.7 0.6 4.2 1.1 2.9 0.5 4.2 1.1 91 15 98 165 7.9 0 8.3 7.8 06/20/2006 09:30:00 2.7 0.5 3.8 1.1 2.6 0.6 3.8 0.4 2.8 0.6 4.2 1.1 67 18 64 165 8.3 0 8.5 8 06/20/2006 09:40:00 3.2 0.5 4.2 1.5 3.1 0.6 4.2 1.5 3.2 0.7 4.6 1.5 48 9 48 165 8.6 0.1 9 8 06/20/2006 09:50:00 2.8 0.8 4.6 0.4 2.7 0.8 4.2 0.4 2.8 0.7 4.2 1.1 39 19 41 165 8.9 0.2 9.3 8.3 06/20/2006 10:00:00 3 0.8 4.9 0.4 3 0.8 5.3 0.4 3 0.8 4.9 1.1 97 22 125 165 9.4 0.2 9.6 8.8 06/20/2006 10:10:00 3.7 0.7 5.3 0.7 3.8 0.7 5.3 0.7 3.7 0.8 5.3 1.1 106 13 112 165 9.7 0.3 10.3 9 06/20/2006 10:20:00 4.3 0.5 5.7 3 4.4 0.6 5.7 3 4.4 0.6 5.7 3 108 7 113 165 9.5 0.1 9.8 9 06/20/2006 10:30:00 5.1 0.5 6.5 3.8 5.2 0.5 6.5 3.8 5.2 0.6 6.5 3.4 109 7 99 165 9.5 0.2 10.3 8.8 06/20/2006 10:40:00 5.2 0.6 6.8 3.4 5.4 0.7 7.2 3.8 5.3 0.6 7.2 3.4 111 7 111 165 9.4 0.1 10.1 9 06/20/2006 10:50:00 5.4 0.6 7.6 3.4 5.6 0.7 7.6 3.8 5.5 0.6 6.8 3.8 117 7 105 165 10.4 0.1 10.9 9.6 06/20/2006 11:00:00 5.4 0.7 6.8 3.4 5.6 0.7 7.2 3.8 5.6 0.7 7.2 3.8 115 9 112 165 9.8 0.2 10.3 9.3 06/20/2006 11:10:00 5.7 0.7 7.6 4.2 5.9 0.7 7.2 4.2 5.8 0.8 7.6 3.4 112 8 105 165 9.4 0.3 9.8 8.5 06/20/2006 11:20:00 5.6 0.6 7.2 3.8 5.8 0.6 7.6 4.2 5.6 0.6 8 3.4 108 7 118 165 8.8 0.2 9.3 8.5 06/20/2006 11:30:00 5.7 0.7 7.6 3 5.9 0.8 8 3.8 5.7 0.8 7.6 3.8 109 9 107 165 8.7 0 9 8.5 06/20/2006 11:40:00 5.3 0.8 7.2 3.4 5.5 0.8 7.6 3.4 5.5 0.8 8 3.8 112 9 111 165 9.5 0.3 9.8 9 06/20/2006 11:50:00 5.9 0.9 8.4 3.4 6.2 1 8.4 3.4 6 1 8 3 110 9 112 165 9.9 0.2 10.3 9.6 06/20/2006 12:00:00 5.6 1 8.4 2.6 5.8 1 8.8 2.6 5.8 0.9 9.1 3.4 112 9 117 165 10.3 0.2 10.9 9.6 06/20/2006 12:10:00 6.2 0.9 8.4 3.8 6.4 1 8.4 3.8 6.3 1 8.4 3.8 112 8 120 165 10.7 0 10.9 10.6 06/20/2006 12:20:00 6.6 0.7 8.4 4.6 6.8 0.7 8.4 4.9 6.8 0.8 8.8 3.8 110 9 105 165 10.3 0.2 10.9 9.8 06/20/2006 12:30:00 6.7 1 9.9 3.8 6.8 1 10.7 3.4 6.8 1.1 9.9 3.8 107 10 102 165 10.1 0.2 10.6 9.6 06/20/2006 12:40:00 6.6 1 9.9 3 6.7 1 9.9 2.6 6.6 1 9.5 4.2 107 11 119 165 10.4 0.1 10.9 10.3 06/20/2006 12:50:00 6.4 1.1 8.8 3.4 6.5 1.1 8.8 3.4 6.4 1.1 9.5 3 107 11 106 165 10.5 0.3 11.1 9.6 06/20/2006 13:00:00 6.8 1.1 9.5 3.8 7 1.2 9.9 4.2 6.8 1.1 9.5 3.8 111 9 107 165 10.3 0 10.6 9.6 06/20/2006 13:10:00 6.9 1 9.1 3.8 7.1 1 9.5 4.2 7 1.1 9.9 4.2 110 9 115 165 10.1 0.1 10.6 9.6 06/20/2006 13:20:00 6.8 1.1 9.5 3.4 7 1.2 9.9 3.8 6.8 1 9.1 3.8 107 11 109 165 10.5 0.4 11.1 9.8 06/20/2006 13:30:00 7.3 1.2 10.3 4.2 7.5 1.2 10.7 4.6 7.2 1.1 10.3 4.6 107 10 91 165 10.7 0.1 11.4 10.1 06/20/2006 13:40:00 7 1.2 9.9 3.4 7.1 1.2 10.3 3.8 6.7 1.2 9.9 3.8 102 12 95 165 11 0.2 11.4 10.6 06/20/2006 13:50:00 7.4 1 10.3 4.9 7.6 1.1 10.3 4.9 7.3 1.1 10.3 4.6 108 10 104 165 10.7 0.3 11.4 10.3 06/20/2006 14:00:00 7.2 1.1 10.3 4.6 7.4 1.2 10.3 4.2 7.1 1.1 9.9 4.2 106 11 109 165 10.7 0.1 10.9 10.3 06/20/2006 14:10:00 7.6 1.2 11.1 4.6 7.8 1.3 11.1 4.6 7.4 1.3 10.7 4.2 106 10 94 165 10.5 0.1 10.9 9.8 06/20/2006 14:20:00 6.8 1.3 9.9 3.8 6.9 1.3 10.3 3.8 6.7 1.3 9.9 3.4 103 15 98 165 10.3 0.2 10.9 9.8 06/20/2006 14:30:00 6.3 1.2 9.9 3.4 6.5 1.2 9.5 3.8 6.2 1.3 9.5 3 100 15 106 165 10.8 0.1 11.1 10.6 06/20/2006 14:40:00 6.7 1.3 9.9 3 6.9 1.3 10.3 3.8 6.7 1.3 9.9 3.4 104 13 105 165 10.7 0.3 11.4 9.8 06/20/2006 14:50:00 6.6 1.2 9.5 4.2 6.8 1.2 9.9 4.2 6.4 1.2 9.5 3.8 104 10 111 165 11.2 0.4 11.9 10.3 06/20/2006 15:00:00 6.8 1.1 10.3 4.2 7 1.1 10.7 4.2 6.7 1.2 10.7 3.8 99 12 87 165 10.9 0.3 11.7 10.3 06/20/2006 15:10:00 7 1.1 9.5 4.2 7.2 1.1 9.9 4.6 6.8 1.2 9.9 4.2 96 11 103 165 10.7 0.4 11.4 10.1 06/20/2006 15:20:00 7.1 1.1 9.9 4.6 7.3 1.2 10.7 4.6 6.6 1.2 9.1 3.4 99 12 113 165 10.1 0.2 10.6 9.6 06/20/2006 15:30:00 5.5 1 8.8 3 5.7 1 8.8 3.4 5.1 1 8.4 3 78 22 98 165 9.5 0.2 9.8 8.8 06/20/2006 15:40:00 4.9 1.2 8 1.5 5 1.1 8.4 2.3 4.8 1.1 7.6 1.9 62 14 52 165 9.5 0 9.8 9 06/20/2006 15:50:00 5.4 1 8.4 3 5.6 1 8.8 3.4 5.3 1.2 8.8 2.6 79 17 69 165 9.7 0.1 9.8 9.3 06/20/2006 16:00:00 5.6 1 8.4 3 5.7 1.1 8.8 3.4 5.6 1 8.4 3.8 62 12 46 165 9 0 9.6 8.8 06/20/2006 16:10:00 4.9 0.8 6.8 3 5 0.8 6.8 3 4.7 0.8 7.2 3 57 13 70 165 9.1 0 9.3 9 06/20/2006 16:20:00 5.7 1.2 8.8 3.4 5.8 1.2 8.8 3.4 5.7 1.1 8 3 49 13 47 165 9 0.1 9.6 8.5 06/20/2006 16:30:00 4.9 1.2 8 2.3 5.1 1.2 8 2.6 5 1.1 8 2.6 52 14 48 165 8.9 0 9.3 8.8 06/20/2006 16:40:00 6 1.1 8.4 3.4 6.2 1.1 8.8 3.8 6 1.1 8.4 3.4 66 11 52 165 8.8 0 9 8.5 06/20/2006 16:50:00 5.3 1.1 8 3 5.5 1 8.4 3.4 5.2 1 8.4 3 61 10 62 165 9.1 0.2 9.6 8.5 06/20/2006 17:00:00 4.6 0.8 7.2 2.6 4.7 0.8 7.6 2.6 4.7 0.9 7.6 1.9 58 15 60 165 9.1 0.1 9.6 8.8 06/20/2006 17:10:00 5.8 1.2 8.4 2.6 5.8 1.2 8.8 3 5.5 1.2 8.4 2.6 54 11 51 165 9 0.2 9.8 8.5 06/20/2006 17:20:00 6 0.9 8 3.8 6 0.9 8 3.8 5.8 0.8 7.6 3.8 52 11 54 165 8.7 0.1 9 8.3 06/20/2006 17:30:00 6.8 1.7 9.9 3 7 1.8 10.3 3 6.6 1.7 9.9 3 59 11 66 165 8.6 0.2 9 8.3 06/20/2006 17:40:00 6.5 1 8.8 3.8 6.7 1 9.1 3.8 6.4 1 8.8 4.2 62 10 63 165 8.8 0 9 8.3 06/20/2006 17:50:00 5 1 7.2 2.3 5.1 1 7.6 2.6 5 1 7.2 3 55 10 59 165 8.9 0 9 8.3 06/20/2006 18:00:00 5.5 1.1 8 2.3 5.7 1.2 8.4 2.6 5.5 1.1 8 3 56 10 54 165 8.5 0.1 9 8.3 06/20/2006 18:10:00 5.5 1.3 8.4 2.6 5.6 1.3 8.8 2.6 5.4 1.2 8 2.6 58 12 73 165 8.7 0.1 9 8.3 06/20/2006 18:20:00 5.5 1.1 8.8 3 5.6 1.1 8.8 3 5.3 1 7.6 3 56 11 54 165 8.3 0 8.5 8 06/20/2006 18:30:00 5.4 1.1 8 3.4 5.5 1.2 8.4 3 5.2 1.1 8.8 3 54 12 53 165 8.3 0 8.5 7.8 06/20/2006 18:40:00 4.6 0.9 7.2 2.6 4.7 0.9 7.2 3 4.6 0.9 7.2 2.6 49 13 34 165 8.3 0 8.5 7.8 06/20/2006 18:50:00 5.5 0.8 7.6 3.8 5.5 0.8 7.6 3.8 5.4 0.8 8 3.8 33 9 44 165 8.1 0 8.3 7.8 06/20/2006 19:00:00 4.9 0.8 6.8 3 4.9 0.8 6.8 3 4.9 0.9 6.8 2.6 31 11 47 165 8.3 0.1 8.8 7.8 06/20/2006 19:10:00 5.2 1 7.6 3 5.1 1 7.6 2.3 5.2 1 7.6 3 28 9 20 165 8.5 0.1 8.8 7.8 06/20/2006 19:20:00 5.6 0.9 7.2 3 5.5 1 7.6 2.6 5.6 0.9 8 3.4 29 9 34 165 8.3 0 8.5 7.5 06/20/2006 19:30:00 5.6 1 8 3 5.6 1 8 3.4 5.6 1 8.4 3 30 9 34 165 8.2 0.1 8.5 7.5 06/20/2006 19:40:00 5.3 1 7.6 2.6 5.3 1 7.6 2.6 5.3 0.9 7.6 3 33 9 31 165 8 0 8.3 7.8 06/20/2006 19:50:00 5.4 0.8 8 3.4 5.4 0.9 7.6 2.3 5.4 0.8 7.6 3.4 28 8 26 165 8.1 0 8.3 7.8 06/20/2006 20:00:00 5.8 0.9 7.6 3 5.8 0.9 7.6 3 5.7 0.9 7.6 3.4 26 8 16 165 8.1 0 8.3 8 06/20/2006 20:10:00 5.1 0.8 7.2 3 5 0.9 7.2 2.6 5.1 0.8 6.8 3 24 9 19 165 8 0.1 8.3 8 06/20/2006 20:20:00 5.7 0.8 7.6 3.4 5.5 1 7.2 2.6 5.6 0.8 7.6 3.4 22 8 25 165 8 0 8.3 7.5 06/20/2006 20:30:00 5.8 0.7 7.6 3.8 5.6 0.8 7.6 3.4 5.9 0.6 8 4.2 20 7 25 165 7.8 0 8 7.5 06/20/2006 20:40:00 5.6 0.6 6.8 3.8 5.4 0.7 6.8 3.8 5.5 0.7 7.6 3.8 21 6 12 165 7.8 0 8 7.5 06/20/2006 20:50:00 5.4 0.8 7.2 3.4 5.3 0.8 7.2 3.4 5.3 0.8 6.8 3.4 26 8 20 165 7.8 0 7.8 7.5 06/20/2006 21:00:00 6 1.1 8.4 3.4 6 1.1 8.8 3.4 6 1.1 8.4 3.8 27 7 31 165 7.8 0 7.8 7.3 06/20/2006 21:10:00 5.1 0.7 6.8 3.4 4.8 0.9 6.5 2.6 4.9 0.8 7.2 3 20 8 15 165 7.6 0 7.8 7.3 06/20/2006 21:20:00 5.4 0.6 7.2 3.8 4.9 0.9 7.2 2.6 5.4 0.6 7.2 3.8 15 7 25 165 7.6 0 7.8 7.3 06/20/2006 21:30:00 5.8 0.6 7.2 3.8 5.3 0.8 6.8 3 5.7 0.6 6.8 4.2 16 6 16 165 7.5 0 7.5 7.3 06/20/2006 21:40:00 5.7 0.6 7.2 4.2 4.8 0.9 6.8 2.6 5.6 0.6 7.2 3.8 13 6 19 165 7.4 0.1 7.5 7 06/20/2006 21:50:00 5.7 0.6 7.2 3.8 5.1 0.9 6.5 2.3 5.7 0.6 7.2 3.8 16 6 13 165 7.4 0 7.5 7 06/20/2006 22:00:00 5.5 0.5 6.8 4.6 5 0.7 6.8 2.6 5.4 0.6 7.2 4.2 17 6 10 165 7.4 0.1 7.8 7 06/20/2006 22:10:00 5.5 0.6 6.8 4.2 5.1 0.6 6.8 3.4 5.3 0.6 6.5 3.8 20 5 23 165 7.4 0.1 7.5 6.7 06/20/2006 22:20:00 5.8 0.6 7.2 4.2 5.3 0.7 6.8 3.4 5.7 0.6 7.2 4.2 17 5 12 165 7.3 0 7.5 6.7 06/20/2006 22:30:00 6.1 0.5 7.2 4.6 5.2 0.8 6.8 2.6 5.9 0.6 7.2 4.2 13 5 16 165 7.3 0 7.5 6.7 06/20/2006 22:40:00 6.3 0.5 7.6 4.9 5.4 0.8 7.2 3.4 6.1 0.5 7.2 4.9 14 4 16 165 7.3 0 7.3 7.3 06/20/2006 22:50:00 6.3 0.5 7.6 4.9 5 0.8 6.8 2.6 6.1 0.5 7.6 4.9 12 4 15 165 7.2 0 7.3 7 06/20/2006 23:00:00 6.7 0.6 8 4.9 4.6 0.9 6.8 2.6 6.6 0.6 8.4 4.9 7 5 15 165 7.3 0 7.5 7.3 06/20/2006 23:10:00 6.5 0.7 8 4.9 5.2 1.1 7.6 2.6 6.4 0.7 8.4 4.6 11 6 14 165 7.3 0 7.5 7.3 06/20/2006 23:20:00 6.1 0.5 7.6 4.2 4.8 1 6.5 2.6 5.9 0.6 7.2 4.2 10 5 20 165 7.4 0 7.5 7.5 06/20/2006 23:30:00 6.5 0.7 8.4 4.6 4.6 1 7.2 2.6 6.3 0.7 8.4 4.6 7 6 4 165 7.4 0 7.5 7.3 06/20/2006 23:40:00 6.9 0.8 9.1 4.6 5.8 1.3 8.4 3 6.7 0.7 9.1 4.6 13 8 14 165 7.6 0 7.8 7.5 06/20/2006 23:50:00 5.8 0.9 8 3.4 5.4 1 8 2.3 5.4 1.1 8.4 2.6 23 13 19 165 7.4 0 7.8 7.3 06/21/2006 00:00:00 5.2 1 8 2.6 5.2 1 8 2.6 5 0.9 7.6 3 43 10 70 165 7.3 0 7.8 7.3 06/21/2006 00:10:00 4 0.8 5.7 2.3 3.9 0.9 5.7 1.9 4.1 0.6 5.7 2.3 36 14 61 165 6.9 0.1 7.3 6.7 06/21/2006 00:20:00 3.9 0.9 6.1 2.3 3.3 1.1 6.1 1.1 4.1 0.8 6.1 2.3 17 12 15 165 6.6 0 7 6.2 06/21/2006 00:30:00 5.6 0.6 7.2 4.2 5.5 0.7 7.6 3.8 5.4 0.5 6.8 3.8 23 5 29 165 6.4 0 6.7 6.2 06/21/2006 00:40:00 6.5 0.6 7.6 4.9 6.1 0.7 7.6 3.8 6.3 0.5 7.6 4.6 17 4 23 165 6.6 0 6.7 6.2 06/21/2006 00:50:00 6.5 0.4 7.6 5.3 5.8 0.6 7.6 3.8 6.3 0.6 7.6 4.6 15 4 18 165 6.8 0 7 6.5 06/21/2006 01:00:00 6.5 0.5 7.6 5.3 5.8 0.8 7.6 3.8 6.4 0.6 8.4 4.6 15 4 20 165 6.9 0 7.3 7 06/21/2006 01:10:00 5.8 0.5 6.8 4.2 4.8 1 6.8 1.9 5.9 0.5 6.8 4.2 14 6 14 165 6.9 0 7 7 06/21/2006 01:20:00 5.8 0.5 7.2 4.2 5.1 0.8 7.2 3 5.8 0.6 7.2 3.8 16 4 19 165 6.9 0 7 6.7 06/21/2006 01:30:00 6.1 0.6 7.6 4.6 5.4 0.8 7.2 3 6 0.6 7.6 4.6 16 4 16 165 6.9 0 7 6.7 06/21/2006 01:40:00 5.8 0.6 7.2 4.2 5.2 0.7 6.8 2.6 5.9 0.6 7.2 4.2 16 4 14 165 6.9 0 7.3 6.7 06/21/2006 01:50:00 5.5 0.5 6.8 4.2 4.3 0.9 6.5 2.3 5.5 0.5 6.8 3.8 11 5 12 165 7.1 0 7.3 7 06/21/2006 02:00:00 5.6 0.6 7.2 4.2 4.1 1.1 6.8 1.9 5.6 0.6 7.2 4.2 8 7 18 165 6.9 0 7.3 7 06/21/2006 02:10:00 5.2 0.6 6.8 3.8 3.6 0.9 5.7 1.5 5.2 0.6 6.8 3.8 7 7 7 165 7 0 7.3 6.7 06/21/2006 02:20:00 4.1 0.5 5.3 2.6 3.1 0.8 4.9 1.1 4.2 0.5 5.7 3 355 9 16 165 6.9 0 7.3 7 06/21/2006 02:30:00 4 0.6 5.3 2.6 2.9 0.8 4.9 1.1 4 0.5 5.3 2.6 356 9 356 165 6.9 0 7 6.7 06/21/2006 02:40:00 5.1 0.8 7.2 3.4 3.7 1 6.1 1.5 5 0.8 6.8 3.4 359 9 7 165 6.9 0 7.3 6.7 06/21/2006 02:50:00 4.9 0.6 6.8 3.8 3.5 0.8 6.1 1.9 4.8 0.6 6.8 3.4 1 8 15 165 6.9 0 7 6.7 06/21/2006 03:00:00 5.8 0.8 7.2 3.8 4.7 1.3 7.2 1.9 5.5 0.7 7.6 3.8 355 6 359 165 6.8 0 7 6.7 06/21/2006 03:10:00 5.2 0.6 6.8 3.8 3.5 1 6.8 1.9 5.1 0.5 6.8 4.2 359 6 6 165 6.8 0 7 6.7 06/21/2006 03:20:00 5.3 0.6 6.8 3.8 3.8 1.1 7.2 2.3 5.1 0.5 6.8 3.8 359 7 351 165 6.7 0 7 6.7 06/21/2006 03:30:00 5 0.7 7.2 3.8 3.3 1 7.2 1.5 5 0.6 6.5 3.8 2 6 5 165 6.8 0 7 6.7 06/21/2006 03:40:00 5.9 0.6 7.2 4.6 4.4 1.3 7.6 2.3 5.8 0.6 7.2 4.6 355 7 346 165 6.8 0 7 6.7 06/21/2006 03:50:00 5.9 0.6 7.6 4.6 5.1 0.9 7.6 2.6 6 0.6 7.6 4.6 352 7 7 165 6.9 0 7 6.7 06/21/2006 04:00:00 6.2 0.5 7.6 4.9 5.6 0.8 8 3.8 6 0.5 7.6 4.6 350 4 340 165 6.9 0 7.5 6.7 06/21/2006 04:10:00 5.7 0.6 7.2 4.2 5.6 0.9 7.6 2.6 5.7 0.7 7.2 3.8 343 7 347 165 6.9 0 7 6.7 06/21/2006 04:20:00 5.3 0.5 6.8 3.8 5 0.8 6.8 2.3 5.5 0.5 6.8 4.2 347 7 360 165 6.9 0 7.3 7 06/21/2006 04:30:00 5.5 0.5 7.2 4.2 5.6 0.6 7.2 3.8 5.6 0.5 7.2 4.2 340 6 339 165 7 0 7.3 7 06/21/2006 04:40:00 5.2 0.6 6.8 3.8 4.8 1 6.8 2.3 5.3 0.5 7.6 4.2 346 9 333 165 7 0 7.3 7 06/21/2006 04:50:00 5.7 0.5 7.2 4.2 5.6 0.7 7.2 3.8 5.7 0.5 6.8 4.2 346 6 349 165 7.1 0 7.3 7 06/21/2006 05:00:00 5.8 0.7 8 4.2 5.3 1.1 7.6 2.6 5.7 0.6 7.2 4.2 346 9 7 165 7.1 0 7.3 7 06/21/2006 05:10:00 6.3 0.6 7.6 4.6 5.7 1.1 7.6 2.6 6.2 0.7 8 4.9 346 8 350 165 7.2 0 7.3 7 06/21/2006 05:20:00 6.8 0.6 8.8 4.9 6.6 0.9 8.8 3.4 6.8 0.7 8.4 4.9 347 5 350 165 7.3 0 7.5 7.3 06/21/2006 05:30:00 7.1 0.9 9.5 4.9 6.7 1.2 9.5 3.4 6.8 0.8 8.8 4.9 348 5 353 165 7.3 0 7.5 7.3 06/21/2006 05:40:00 7 0.8 9.1 4.9 6.2 1.2 9.1 3 6.9 0.8 9.1 4.9 349 8 350 165 7.4 0 7.5 7.3 06/21/2006 05:50:00 7.6 0.8 9.9 5.7 6.6 1.2 9.5 3.4 7.5 1 9.9 4.9 349 9 1 165 7.5 0 7.8 7.5 06/21/2006 06:00:00 7 0.9 9.5 5.3 6.3 1.3 9.5 3.4 6.9 0.8 9.5 4.9 347 10 349 165 7.6 0 8 7.5 06/21/2006 06:10:00 6.4 0.7 9.5 4.2 6.2 1 9.5 3 6.3 0.6 8.4 4.6 343 7 338 165 7.6 0 7.8 7.5 06/21/2006 06:20:00 6.7 0.6 8.4 4.6 6.4 0.9 8.4 3.4 6.5 0.6 8.4 4.6 341 9 344 165 7.7 0 8 7.5 06/21/2006 06:30:00 8 1.1 10.3 4.9 7.6 1.7 10.7 3.4 7.9 1.1 11.1 5.3 344 10 349 165 8 0 8.3 7.8 06/21/2006 06:40:00 7.5 1 10.7 5.7 6.9 1.2 11.1 3.4 7.5 1.1 11.8 5.3 345 11 345 165 8.1 0 8.5 8 06/21/2006 06:50:00 7 0.9 9.5 5.3 6.4 1.2 9.9 3.4 6.9 1 9.9 4.6 346 9 347 165 8.3 0 8.5 8.3 06/21/2006 07:00:00 7.9 1.1 11.1 4.9 7.3 1.6 11.5 3.4 7.8 1.1 11.1 4.9 346 11 344 165 8.4 0 8.8 7.8 06/21/2006 07:10:00 7.3 0.7 9.1 5.3 7 1 9.5 3.8 7.1 0.7 9.1 5.3 343 9 354 165 8.5 0 8.8 8 06/21/2006 07:20:00 8.1 1 10.3 5.7 8 0.9 10.3 5.3 7.8 1 10.3 5.3 331 7 330 165 8.7 0 9 8.3 06/21/2006 07:30:00 7.5 1 10.3 5.3 7.3 1 9.9 4.2 7.2 0.9 9.5 4.9 334 13 359 165 8.7 0 8.8 8.3 06/21/2006 07:40:00 8.2 1.2 12.2 5.7 8.1 1.2 11.8 5.3 7.6 1 11.5 5.3 333 7 332 165 8.8 0 9 8.3 06/21/2006 07:50:00 8 1.3 11.1 4.9 7.8 1.3 11.1 4.6 7.6 1.3 10.7 4.6 331 9 325 165 8.7 0 9 8.5 06/21/2006 08:00:00 7 1.1 11.1 3.8 6.3 1.3 9.9 2.6 6.8 1 9.9 4.2 345 13 4 165 8.9 0 9 8.8 06/21/2006 08:10:00 8.1 1.1 10.7 5.3 6.2 1.5 9.9 3 8.2 1.1 11.1 5.7 360 11 2 165 8.5 0.1 9 8.3 06/21/2006 08:20:00 7.4 1.5 10.7 3.8 6.6 1.5 10.3 3.4 7.1 1.5 11.5 3.8 344 12 360 165 8.3 0 8.5 8.3 06/21/2006 08:30:00 7.9 1.2 11.1 4.6 6.9 1.3 10.3 4.2 7.6 1.3 10.7 4.2 350 12 10 165 8.3 0 8.5 8.3 06/21/2006 08:40:00 8.2 1.1 10.7 4.9 7 1.6 11.1 3.8 8 1.3 10.7 4.6 356 9 349 165 8.2 0 8.5 8.3 06/21/2006 08:50:00 7.3 0.9 9.5 5.3 6.4 1.1 9.1 3.8 7.1 1 9.5 4.6 351 11 355 165 8.5 0.1 8.8 8.3 06/21/2006 09:00:00 8.2 1.8 12.6 4.6 7.4 2 13 3 7.9 1.8 12.6 4.9 347 11 353 165 8.7 0 9 8.5 06/21/2006 09:10:00 6.7 1.2 8.8 2.6 6.5 1.2 8.8 2.3 6.4 1.2 8.4 2.6 336 12 360 165 9.4 0.2 9.8 8.8 06/21/2006 09:20:00 7.3 1.3 10.7 4.6 7.2 1.4 10.7 2.6 7 1.1 9.9 4.6 329 11 323 165 9.8 0 10.1 9.6 06/21/2006 09:30:00 7.2 1.1 9.9 4.6 7 1.2 9.5 3.8 6.6 1.2 9.9 3.8 332 15 328 165 10 0 10.3 9.6 06/21/2006 09:40:00 6.7 1.2 9.9 3.4 6.4 1.3 9.9 3 6.3 1.2 9.9 2.6 333 15 319 165 9.9 0.1 10.6 9.6 06/21/2006 09:50:00 6.3 1 9.5 4.2 6.2 1.1 9.5 3.4 6.1 1 9.1 3.8 335 13 329 165 10.6 0.2 11.1 10.1 06/21/2006 10:00:00 7.7 1 9.9 4.6 7.3 1.3 9.9 3.8 7.4 1 10.3 4.6 338 15 351 165 11 0 11.4 10.6 06/21/2006 10:10:00 6.6 0.9 8.8 4.2 6.5 0.9 8.8 3.4 6.2 0.9 8.4 3.8 330 9 340 165 11.6 0.1 11.9 11.4 06/21/2006 10:20:00 6.1 1 8.8 3 6 1 8.4 3 6 0.9 8.4 3.8 332 10 331 165 12.1 0 12.5 11.7 06/21/2006 10:30:00 5.9 1.2 8.8 2.6 4.9 1.1 8 2.3 5.7 1.2 9.5 2.6 351 16 7 165 11.4 0.1 11.9 11.1 06/21/2006 10:40:00 6.3 1.3 10.7 3.8 4.9 1.2 8 2.3 6.1 1.3 9.9 3 358 11 358 165 11.3 0.2 11.7 10.9 06/21/2006 10:50:00 7.7 1 10.7 5.3 6.1 1.1 8.8 3.4 7.6 1.1 10.7 4.6 0 12 356 165 11.8 0.3 12.5 10.9 06/21/2006 11:00:00 6.3 1.5 9.9 3.4 5.6 1.7 9.1 1.9 6.2 1.4 9.9 3.4 349 17 12 165 11.1 0.3 11.7 10.6 06/21/2006 11:10:00 6.3 1.3 10.3 3.8 5.1 1.3 8.8 1.9 6.3 1.3 10.3 3.8 359 12 19 165 11 0.2 11.4 10.9 06/21/2006 11:20:00 5.5 1.1 8.8 3 5.3 1 8 2.6 5.5 1.1 8.4 3.4 341 15 9 165 12.2 0.4 12.7 11.4 06/21/2006 11:30:00 6.9 1.3 9.9 3.8 5.6 1.3 9.5 2.6 6.8 1.3 10.7 3.8 355 11 19 165 12.3 0.1 12.5 11.7 06/21/2006 11:40:00 6.8 1 9.5 4.2 5.9 1.1 8.4 3 6.6 1.1 11.1 4.2 352 12 9 165 12.2 0.1 12.5 11.7 06/21/2006 11:50:00 6.6 1.2 9.9 4.2 5.4 1.3 9.1 2.6 6.5 1.4 10.7 3.8 7 10 14 165 11.7 0.1 12.5 11.1 06/21/2006 12:00:00 6.5 1.2 9.9 3.8 5.5 1.3 8.8 2.6 6.2 1 8.4 3.4 8 11 321 165 11.4 0.1 11.9 10.9 06/21/2006 12:10:00 7.6 1.2 11.1 4.6 6.2 1.5 11.1 3 7.4 1.3 11.1 4.2 5 12 6 165 11.3 0.2 11.9 10.9 06/21/2006 12:20:00 7.5 1.1 11.5 5.3 6.6 1.5 11.1 3.4 7.5 1 10.7 4.9 11 12 15 165 10.4 0.2 11.1 9.8 06/21/2006 12:30:00 7.2 1.3 10.3 3.8 6.3 1.3 9.9 3 6.8 1.2 9.5 3.8 360 13 12 165 10 0.2 10.3 9.6 06/21/2006 12:40:00 5.6 1 7.6 3.4 5.1 1 8 2.6 5.5 0.8 7.2 3.4 349 17 357 165 10.4 0.1 10.9 9.8 06/21/2006 12:50:00 5.1 1 8.4 1.9 5.2 1 7.6 2.6 4.7 0.9 7.2 2.6 329 12 330 165 10.4 0.1 11.1 9.8 06/21/2006 13:00:00 6.3 1.4 11.1 3.8 5.5 1.3 10.3 2.6 6.2 1.4 10.7 3.4 356 11 3 165 10.7 0.2 10.9 10.1 06/21/2006 13:10:00 6.3 0.7 8.4 4.2 5.9 1 8 3.4 6.3 0.7 8.4 4.2 348 17 331 165 10.3 0.2 11.1 9.6 06/21/2006 13:20:00 8 1.3 12.6 5.3 8 1.3 12.2 5.7 7.6 1.3 12.6 5.3 330 10 318 165 9.6 0.2 10.1 9 06/21/2006 13:30:00 9.8 1.5 13.7 6.1 9.8 1.5 14.1 6.5 9.6 1.5 13.3 6.5 334 9 342 165 9.2 0.2 9.6 8.8 06/21/2006 13:40:00 7.9 1.2 10.7 4.6 7.7 1.3 10.7 4.6 7.3 1.3 11.1 4.2 333 14 333 165 9.4 0.1 9.6 9 06/21/2006 13:50:00 8.4 1.3 11.8 5.7 8 1.6 12.2 3.8 8 1.3 12.6 4.9 341 11 338 165 9.5 0.1 9.8 9 06/21/2006 14:00:00 8.2 1.3 14.1 5.3 8.2 1.3 13.7 4.9 8 1.3 13 4.9 327 10 327 165 9.6 0.2 10.1 9 06/21/2006 14:10:00 7.9 1.3 11.5 4.9 7.8 1.3 11.5 4.9 7.3 1.5 11.5 3.8 329 13 335 165 9.4 0 9.6 9 06/21/2006 14:20:00 7.5 1 10.7 4.2 7.4 1.1 9.9 4.2 7.3 1 9.5 4.6 337 12 325 165 9.2 0 9.6 9 06/21/2006 14:30:00 6.8 0.9 9.1 4.6 5.9 1.3 8.8 3 6.8 1 9.5 4.2 350 13 0 165 9.2 0 9.3 9 06/21/2006 14:40:00 6.4 1 9.9 4.2 5.6 1.1 9.9 3 6.6 1 9.5 4.2 352 10 359 165 9.2 0 9.6 9 06/21/2006 14:50:00 6.4 1.2 9.9 4.2 5.4 1.2 9.5 3 6.4 1.1 9.5 3.8 356 10 7 165 9.3 0 9.6 9 06/21/2006 15:00:00 6.1 1.7 9.9 3 5.5 1.7 10.3 2.3 6 1.5 9.9 3.4 348 10 351 165 9.8 0.2 10.3 9.3 06/21/2006 15:10:00 7.2 1.2 9.9 4.6 6.6 1.1 9.1 3.4 7.2 1.3 10.3 4.2 346 10 11 165 10 0.1 10.3 9.3 06/21/2006 15:20:00 6.5 1.3 10.7 4.2 5.7 1.1 8.8 2.6 6.2 1.3 9.5 3.8 349 9 5 165 9.6 0.1 9.6 9 06/21/2006 15:30:00 6.6 1 9.1 4.2 5.7 1.2 8.8 3 6.4 1 9.5 3.8 352 8 4 165 9.4 0.1 9.6 9 06/21/2006 15:40:00 6 0.8 8.4 4.2 5.3 1.1 8 3 5.8 0.7 8.8 4.2 351 8 359 165 9.4 0.1 10.1 9 06/21/2006 15:50:00 6.9 0.8 9.9 4.9 6.2 1.3 9.9 3 6.5 0.9 8.4 4.2 350 8 346 165 9.3 0 9.8 9 06/21/2006 16:00:00 7.5 1 9.5 4.2 6.9 1.5 10.3 3.4 7.1 1 9.5 4.6 346 11 347 165 9 0.1 9.6 8.8 06/21/2006 16:10:00 7.5 1.2 10.7 4.6 6.7 1.2 10.3 3.4 7.1 1.2 10.7 4.2 350 11 2 165 9.1 0.1 9.6 8.8 06/21/2006 16:20:00 7.7 0.9 9.5 4.6 6.3 1.2 9.9 3.8 7.7 1 11.5 4.2 353 7 3 165 9 0.2 9.6 8.5 06/21/2006 16:30:00 8.3 1.4 11.8 5.7 7.7 1.7 11.8 3.8 7.9 1.4 11.8 4.9 348 9 1 165 9.2 0.1 9.6 8.5 06/21/2006 16:40:00 7.9 1 11.8 5.7 6.7 1.4 10.3 3.8 7.6 1 10.3 5.3 354 8 4 165 9.4 0.2 9.8 8.8 06/21/2006 16:50:00 7.5 0.9 9.9 4.9 6.3 1.4 9.1 3.4 7.2 0.9 9.1 4.9 353 8 355 165 9.6 0.1 9.8 9 06/21/2006 17:00:00 7.2 1 9.9 4.6 6.8 1.3 9.9 3 7.1 1 10.7 4.2 348 8 355 165 9.8 0 10.1 9.3 06/21/2006 17:10:00 7.7 1.3 11.5 4.9 6.3 1.3 9.5 3.4 7.5 1.2 11.1 4.6 357 11 357 165 10 0 10.3 9.6 06/21/2006 17:20:00 8.7 0.9 10.7 5.3 6.1 1.4 9.5 3.4 8.7 1 11.1 4.9 0 8 3 165 10.1 0 10.6 9.6 06/21/2006 17:30:00 7.4 0.8 10.3 5.3 5.5 1.2 8.8 3 7.2 1 9.5 4.6 4 9 9 165 10 0.1 10.6 9.3 06/21/2006 17:40:00 7.1 1 9.9 4.6 5.6 1.1 8 3.4 6.9 0.9 9.1 5.3 357 11 4 165 9.9 0 10.3 9.3 06/21/2006 17:50:00 6.6 0.7 8.8 4.6 4.8 1.1 8 2.6 6.5 0.8 8.8 4.9 359 7 357 165 10.1 0 10.3 9.6 06/21/2006 18:00:00 8.5 0.8 10.7 6.8 5.9 1.2 9.1 3.4 8.4 0.8 10.7 6.1 5 6 3 165 10.3 0 10.9 9.8 06/21/2006 18:10:00 7.8 1 10.3 5.7 5.7 1.5 9.1 2.6 7.6 0.9 9.9 4.9 4 8 3 165 10.2 0.1 10.6 9.6 06/21/2006 18:20:00 6.8 1.3 10.3 4.2 4.6 1.1 8.4 2.6 6.8 1.5 10.3 3.4 2 7 4 165 9.9 0 10.3 9.6 06/21/2006 18:30:00 6.5 0.7 8.4 4.6 4.8 1.2 8.8 2.3 6.4 0.7 8.8 4.2 357 8 357 165 9.9 0 10.3 9.6 06/21/2006 18:40:00 7.2 1 10.7 4.9 5.4 1.3 9.1 3 7 0.9 9.5 4.6 357 9 358 165 10.1 0 10.3 9.8 06/21/2006 18:50:00 7.9 1.1 10.7 5.7 6 1.6 9.5 2.6 7.7 1.2 10.7 4.2 357 9 4 165 10.1 0.1 10.6 9.6 06/21/2006 19:00:00 5.6 1 8.4 2.6 4.2 1 8 2.3 5.4 1 8 2.6 358 9 357 165 10.3 0 10.6 9.8 06/21/2006 19:10:00 6.3 1 9.5 3.8 5.5 1.2 8.4 2.3 5.8 0.9 8.4 3.8 355 11 10 165 10.1 0.2 10.6 9.6 06/21/2006 19:20:00 6.4 0.9 8.8 4.6 4.7 1.2 8.8 2.6 6.2 0.9 8.8 3.8 4 8 3 165 9.6 0.1 9.8 9.3 06/21/2006 19:30:00 6.4 0.8 8.4 4.2 4.9 1.2 8 2.3 6 0.9 8 3.8 357 8 11 165 9.6 0.1 9.8 9.3 06/21/2006 19:40:00 6.2 1 8.8 3.8 4.6 1.1 9.1 2.6 5.9 1 8.4 3.4 357 8 354 165 9.6 0.1 9.8 9 06/21/2006 19:50:00 5.8 1.3 8.8 2.6 5.2 1.3 8.8 2.3 5.3 1.5 9.5 1.1 345 13 4 165 9.7 0.1 10.3 9.3 06/21/2006 20:00:00 4 0.9 6.5 1.5 3.5 1.1 6.8 0.7 3.7 0.8 5.7 0.7 351 11 355 165 9.8 0 10.3 9.3 06/21/2006 20:10:00 4.8 1.1 7.2 1.5 4.2 1.2 7.2 1.5 4.3 1 6.8 1.9 350 10 6 165 9.8 0.1 10.6 9.3 06/21/2006 20:20:00 5.2 0.8 7.2 3 4.2 1.1 6.5 1.9 5 0.8 6.8 2.6 358 9 354 165 9.5 0.2 9.8 8.8 06/21/2006 20:30:00 5.4 0.7 7.2 3 4 1 6.5 1.9 5.1 0.8 7.2 3 355 6 354 165 9.4 0.1 9.8 8.8 06/21/2006 20:40:00 5.4 0.9 7.6 3.4 4.9 1 7.2 2.6 5.3 0.8 8 3.4 15 12 348 165 9 0.1 9.3 8.5 06/21/2006 20:50:00 5.7 0.6 7.2 3.8 4.9 0.7 6.5 3 5.6 0.6 6.8 3.8 13 7 359 165 8.8 0 8.8 8.5 06/21/2006 21:00:00 5.7 0.5 7.6 4.2 4.7 1 6.8 2.3 5.6 0.5 6.8 4.2 12 6 7 165 8.8 0 9 8.5 06/21/2006 21:10:00 6.2 0.7 7.6 4.2 5.6 1 7.2 2.6 6.1 0.7 7.6 4.2 16 6 18 165 8.8 0 9 8.5 06/21/2006 21:20:00 5.2 0.8 6.8 3 4.8 1 6.8 1.9 5 0.8 6.8 3.4 18 8 23 165 8.7 0 8.8 8.5 06/21/2006 21:30:00 5.3 0.4 6.5 4.2 4.7 0.8 6.5 2.6 5.3 0.5 7.6 3.8 15 5 24 165 8.7 0 8.8 8.5 06/21/2006 21:40:00 5.2 0.6 7.2 3.4 4.7 0.9 6.8 1.9 5.1 0.7 7.6 3.8 16 6 21 165 8.7 0 8.8 8.5 06/21/2006 21:50:00 5.4 0.5 6.8 3.8 4.5 1 6.5 1.9 5.5 0.5 6.8 4.2 13 6 11 165 8.7 0 8.8 8.8 06/21/2006 22:00:00 5.8 0.5 6.8 4.6 4.8 1 6.8 2.6 5.9 0.5 7.2 4.2 12 9 21 165 8.7 0 8.8 8.5 06/21/2006 22:10:00 5.5 0.6 7.2 4.2 5.3 0.7 7.2 2.6 5.6 0.8 8 3.4 20 6 21 165 8.6 0 8.8 8.5 06/21/2006 22:20:00 4.4 0.6 6.1 2.6 4.1 0.8 6.1 1.5 4.4 0.5 6.1 2.6 18 7 19 165 8.5 0 8.8 8.5 06/21/2006 22:30:00 4.6 0.4 5.3 3.8 4.2 0.6 5.3 2.3 4.7 0.4 5.3 3.8 16 5 12 165 8.5 0 8.8 8.5 06/21/2006 22:40:00 4.8 0.5 6.1 3.4 3.5 1 5.7 1.5 4.9 0.5 6.1 3.8 8 7 354 165 8.5 0 8.8 8.5 06/21/2006 22:50:00 5 0.5 6.5 4.2 4.6 0.6 6.1 2.3 5 0.5 6.5 3.4 16 5 357 165 8.5 0 8.8 8.5 06/21/2006 23:00:00 4 0.7 5.7 1.9 3.8 0.7 5.3 1.5 4.1 0.7 5.7 2.3 19 9 15 165 8.5 0 8.8 8.5 06/21/2006 23:10:00 4.6 0.5 6.1 3 4.5 0.6 6.1 2.6 4.6 0.5 5.7 3 24 7 29 165 8.5 0 8.8 8.5 06/21/2006 23:20:00 5.8 0.5 7.2 4.6 5.8 0.4 6.8 4.2 5.8 0.5 7.2 4.6 24 5 10 165 8.5 0 8.5 8.5 06/21/2006 23:30:00 5.5 0.6 6.8 3.4 5.3 0.7 6.8 3 5.5 0.7 6.8 3.4 21 6 27 165 8.5 0 8.5 8.5 06/21/2006 23:40:00 5.3 0.5 6.5 3.4 5.3 0.6 6.5 3.4 5.3 0.6 6.5 3 27 6 27 165 8.3 0 8.5 7.8 06/21/2006 23:50:00 5.1 0.4 6.1 3.8 4.9 0.6 6.5 2.6 5.1 0.5 6.8 3.8 20 5 26 165 8.3 0 8.5 7.8 06/22/2006 00:00:00 5 0.4 6.1 3.8 4.8 0.5 6.1 3.4 5.2 0.5 6.5 3.8 20 5 25 165 8.2 0 8.5 7.8 06/22/2006 00:10:00 4.7 0.6 6.5 3.4 3.9 1.1 6.1 1.1 4.8 0.6 6.1 3 13 7 19 165 8.2 0 8.5 7.8 06/22/2006 00:20:00 4.2 0.6 5.7 3 3.7 0.8 5.3 1.5 4.4 0.6 5.7 3 14 7 16 165 8.3 0 8.5 7.8 06/22/2006 00:30:00 4.6 0.6 5.7 3 4.4 0.8 5.7 1.9 4.6 0.6 5.7 3 19 8 18 165 8.3 0 8.5 7.8 06/22/2006 00:40:00 4 0.6 4.9 1.9 3.9 0.7 4.9 1.5 4.1 0.6 5.3 2.3 23 8 19 165 8.2 0 8.3 7.5 06/22/2006 00:50:00 4 0.5 4.9 2.3 3.9 0.5 4.9 2.3 4 0.5 5.3 2.3 28 7 27 165 8.1 0.1 8.3 7.5 06/22/2006 01:00:00 3.8 0.6 4.9 1.9 3.8 0.6 4.9 1.1 3.9 0.6 4.9 1.9 28 6 29 165 8 0.1 8.3 7.5 06/22/2006 01:10:00 3.7 0.6 4.6 1.5 3.5 0.8 4.6 0.7 3.7 0.7 4.9 1.5 23 7 18 165 7.9 0.1 8 7.5 06/22/2006 01:20:00 4.3 0.3 5.3 3.4 4.2 0.3 4.9 3.4 4.3 0.4 4.9 3 21 3 25 165 7.8 0 8 7.3 06/22/2006 01:30:00 4.2 0.4 5.3 2.6 4.1 0.4 5.7 2.6 4.2 0.5 5.3 2.3 22 4 31 165 7.8 0 8 7.5 06/22/2006 01:40:00 3.8 0.5 4.6 3 3.8 0.5 4.6 2.6 3.8 0.4 4.9 3 20 2 22 165 7.7 0 8 7.3 06/22/2006 01:50:00 3.8 0.5 4.9 3 3.5 0.4 4.2 2.3 3.8 0.5 4.9 2.6 17 4 13 165 7.6 0 7.8 7 06/22/2006 02:00:00 4.1 0.3 4.9 3.4 2.9 0.6 4.2 1.5 4.3 0.4 5.3 3.4 10 3 10 165 7.3 0 7.5 7.3 06/22/2006 02:10:00 3.5 0.4 4.6 2.6 3.3 0.4 4.2 1.1 3.6 0.4 4.6 2.6 19 3 18 165 7.3 0 7.5 7.3 06/22/2006 02:20:00 3.7 0.4 4.6 2.6 3 0.7 4.2 1.1 3.8 0.3 4.6 3 11 6 360 165 7.3 0 7.5 7.3 06/22/2006 02:30:00 3.4 0.3 4.6 2.6 2.1 0.7 3.8 0.7 3.5 0.3 4.2 3 7 3 14 165 7.4 0 7.5 7.3 06/22/2006 02:40:00 2.6 0.3 3.4 1.9 2 0.6 3 0.7 2.8 0.3 3.4 2.3 347 10 5 165 7.3 0 7.5 7 06/22/2006 02:50:00 2.4 0.3 3.4 1.5 2.4 0.3 3.4 1.5 2.6 0.3 3.4 1.9 332 5 334 165 7.1 0 7.3 7 06/22/2006 03:00:00 1.8 0.4 2.6 0.7 1.7 0.5 2.6 0.7 1.8 0.6 2.6 0.7 316 6 321 165 6.9 0 7.3 7 06/22/2006 03:10:00 1 0.3 1.5 0.4 0.8 0.3 1.5 0.4 0.8 0.3 1.5 0.4 310 9 328 165 7.1 0 7.5 6.7 06/22/2006 03:20:00 1 0.2 1.5 0.7 0.7 0.3 1.5 0.4 1 0.4 1.9 0.4 308 6 302 165 7.3 0 7.5 7 06/22/2006 03:30:00 1.2 0.3 1.9 0.4 1 0.4 1.9 0.4 1.4 0.3 2.3 0.4 335 7 331 165 7.3 0 7.5 7.3 06/22/2006 03:40:00 0.8 0.4 1.9 0.4 0.6 0.4 1.9 0.4 0.6 0.4 1.9 0.4 330 3 330 165 7.2 0 7.3 7 06/22/2006 03:50:00 1.4 0.3 2.3 0.7 0.8 0.5 1.9 0.4 1.3 0.3 1.9 0.7 349 8 348 165 7.3 0 7.5 7 06/22/2006 04:00:00 0.9 0.3 1.5 0.4 0.5 0.2 1.1 0.4 0.8 0.3 1.1 0.4 339 1 339 165 7.3 0 7.5 7.3 06/22/2006 04:10:00 0.7 0.3 1.5 0.4 0.5 0.3 1.5 0.4 0.7 0.3 1.9 0.4 330 14 305 165 7.5 0.1 7.8 7.3 06/22/2006 04:20:00 1.4 0.4 2.3 0.7 1.4 0.4 2.3 0.7 1.4 0.5 2.6 0.4 287 6 282 165 7.8 0 8 7.5 06/22/2006 04:30:00 0.6 0.4 1.5 0.4 0.6 0.4 1.5 0.4 0.7 0.4 1.5 0.4 291 0 291 165 7.8 0 8 7.5 06/22/2006 04:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 291 0 165 165 8 0 8.3 7.5 06/22/2006 04:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 291 0 165 165 8.3 0 8.5 8.3 06/22/2006 05:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 291 0 165 165 8.3 0 8.5 8.3 06/22/2006 05:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 291 0 165 165 8.3 0 8.5 8.3 06/22/2006 05:20:00 0.4 0 0.7 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 349 35 9 165 8.5 0 8.5 8.3 06/22/2006 05:30:00 0.6 0.3 1.5 0.4 0.4 0.1 1.1 0.4 0.6 0.3 1.1 0.4 9 0 9 165 8.5 0 8.8 8.5 06/22/2006 05:40:00 0.7 0.2 1.1 0.4 0.4 0.2 1.1 0.4 0.7 0.2 1.1 0.4 9 0 9 165 8.7 0 9 8.5 06/22/2006 05:50:00 0.8 0.2 1.5 0.4 0.6 0.3 1.1 0.4 0.7 0.3 1.5 0.4 9 0 9 165 8.9 0 9 8.8 06/22/2006 06:00:00 0.5 0.2 1.1 0.4 0.4 0.1 1.1 0.4 0.5 0.3 1.1 0.4 9 0 9 165 9 0 9 8.8 06/22/2006 06:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 9 0 165 165 9 0.1 9.3 8.5 06/22/2006 06:20:00 0.4 0.2 1.1 0.4 0.4 0 0.4 0.4 0.6 0.3 1.1 0.4 307 33 262 165 9 0.1 9 8.5 06/22/2006 06:30:00 0.4 0.2 1.1 0.4 0.4 0 0.4 0.4 0.5 0.2 1.1 0.4 262 7 262 165 9.1 0.1 9.6 8.5 06/22/2006 06:40:00 0.4 0 0.7 0.4 0.4 0 0.4 0.4 0.4 0 0.7 0.4 212 0 213 165 9.5 0 9.8 9.3 06/22/2006 06:50:00 0.4 0 0.7 0.4 0.4 0 0.4 0.4 0.4 0.1 0.7 0.4 198 21 159 165 10 0.3 10.9 9.6 06/22/2006 07:00:00 0.5 0.3 1.5 0.4 0.5 0.3 1.9 0.4 0.5 0.3 1.5 0.4 132 23 129 165 10.9 0.3 11.4 10.3 06/22/2006 07:10:00 0.7 0.5 1.9 0.4 0.8 0.5 1.9 0.4 0.7 0.4 2.3 0.4 88 61 59 165 11.7 0.2 12.2 11.1 06/22/2006 07:20:00 1.3 0.5 2.3 0.4 1.4 0.5 2.3 0.4 1.4 0.5 2.3 0.4 50 13 46 165 11.2 0.2 11.9 10.9 06/22/2006 07:30:00 0.9 0.4 2.3 0.4 0.8 0.5 2.3 0.4 0.8 0.5 1.9 0.4 20 10 29 165 11.7 0.3 12.2 10.9 06/22/2006 07:40:00 1.1 0.4 2.3 0.4 0.8 0.4 1.9 0.4 1.2 0.5 2.3 0.4 356 10 358 165 12.2 0.1 12.5 11.4 06/22/2006 07:50:00 1 0.4 1.9 0.4 0.8 0.4 1.9 0.4 1.2 0.4 2.3 0.4 360 11 344 165 12.5 0 12.7 11.7 06/22/2006 08:00:00 0.5 0.3 1.5 0.4 0.6 0.4 2.3 0.4 0.5 0.4 1.9 0.4 24 43 70 165 12.4 0.2 12.7 11.7 06/22/2006 08:10:00 0.9 0.5 2.3 0.4 1 0.5 2.6 0.4 0.9 0.5 2.6 0.4 360 82 356 165 12.8 0.1 13 12.5 06/22/2006 08:20:00 0.6 0.4 1.9 0.4 0.6 0.3 1.5 0.4 0.5 0.3 1.5 0.4 121 94 61 165 13.1 0.2 13.5 12.7 06/22/2006 08:30:00 0.6 0.3 1.9 0.4 0.5 0.3 1.5 0.4 0.4 0.1 1.5 0.4 1 66 1 165 14 0.1 14.4 13.5 06/22/2006 08:40:00 1.2 0.6 3 0.4 1.1 0.6 2.6 0.4 1 0.7 3 0.4 152 26 146 165 13.7 0.4 14.4 12.7 06/22/2006 08:50:00 1.7 0.6 3 0.4 1.7 0.5 3 0.7 1.7 0.5 3 0.4 147 18 164 165 12.1 0.2 12.7 11.7 06/22/2006 09:00:00 2.1 0.8 4.2 0.4 2.3 0.7 3.8 0.7 2.3 0.6 3.8 0.4 128 17 154 165 12.2 0.2 12.5 11.7 06/22/2006 09:10:00 2.3 0.7 4.2 1.1 2.5 0.6 4.6 1.1 2.5 0.6 3.8 0.7 112 15 132 165 11.6 0 11.9 11.4 06/22/2006 09:20:00 3.3 0.8 4.9 1.5 3.5 0.8 4.9 1.5 3.3 0.7 4.9 1.5 116 15 110 165 11.4 0.1 11.7 11.1 06/22/2006 09:30:00 3.3 0.6 4.9 1.5 3.4 0.6 4.9 1.9 3.3 0.6 4.6 1.5 119 13 118 165 11.3 0.1 11.7 11.1 06/22/2006 09:40:00 2.9 0.5 4.6 1.5 3.1 0.5 4.6 1.9 2.9 0.5 4.2 1.1 103 19 107 165 11.8 0.3 12.5 11.1 06/22/2006 09:50:00 2.8 0.6 4.6 1.5 3.1 0.6 5.3 1.5 2.9 0.6 5.3 1.1 83 17 62 165 11.7 0.2 12.2 11.1 06/22/2006 10:00:00 3.1 0.8 4.9 0.7 3.3 0.7 4.9 1.1 3.2 0.7 4.6 0.7 99 27 90 165 12.5 0.4 13.3 11.9 06/22/2006 10:10:00 3.5 0.6 4.9 1.5 3.7 0.5 5.3 2.3 3.5 0.6 4.9 1.5 108 16 105 165 13.1 0 13.3 13 06/22/2006 10:20:00 2.8 0.7 4.6 0.7 3 0.7 4.6 0.4 2.6 0.8 4.6 0.4 84 29 108 165 13.2 0.1 13.5 12.7 06/22/2006 10:30:00 3.1 0.7 4.9 0.7 3.3 0.7 4.9 1.1 2.9 0.8 4.9 1.1 101 24 87 165 12.9 0.1 13.3 12.7 06/22/2006 10:40:00 3.5 0.5 5.3 1.9 3.7 0.6 5.3 2.3 3.6 0.5 4.9 2.3 111 9 106 165 12.5 0.1 13 12.2 06/22/2006 10:50:00 3.1 0.5 4.6 1.1 3.2 0.5 4.9 1.5 3.3 0.5 4.9 1.9 115 11 122 165 12.2 0 12.7 11.9 06/22/2006 11:00:00 3.2 0.6 4.6 1.9 3.4 0.6 4.9 1.9 3.3 0.6 4.9 1.9 116 9 102 165 12.2 0 12.5 12.2 06/22/2006 11:10:00 3.6 0.5 4.9 2.3 3.7 0.5 4.9 2.3 3.7 0.6 4.9 2.3 112 9 128 165 12.1 0 12.5 11.9 06/22/2006 11:20:00 3.8 0.6 6.1 2.3 4 0.6 5.7 2.6 3.8 0.6 5.7 2.3 110 13 108 165 12.4 0 12.7 12.2 06/22/2006 11:30:00 4 0.7 5.7 2.3 4.2 0.7 6.1 2.3 4 0.8 5.7 1.5 98 15 92 165 12.9 0 13 12.7 06/22/2006 11:40:00 4 0.7 6.1 2.3 4.3 0.7 6.1 2.6 4 0.9 5.7 1.5 98 15 120 165 13 0 13.3 12.7 06/22/2006 11:50:00 2.9 0.9 5.7 1.1 3.1 0.8 5.3 1.1 2.8 0.8 5.3 0.4 53 26 40 165 12.7 0 13 12.5 06/22/2006 12:00:00 3.9 0.8 5.7 0.7 3.9 0.8 5.7 1.1 3.9 0.9 6.1 1.5 37 13 29 165 12.1 0.1 12.7 11.9 06/22/2006 12:10:00 4.6 0.9 6.5 2.6 4.7 0.9 6.8 2.6 4.6 1 6.8 2.3 35 10 29 165 11.4 0.4 12.2 10.3 06/22/2006 12:20:00 4.9 0.6 6.5 3 5 0.6 6.5 3 4.9 0.6 6.5 2.6 39 6 35 165 10.5 0 11.4 10.3 06/22/2006 12:30:00 4.3 0.6 5.7 2.3 4.4 0.6 5.7 2.6 4.2 0.7 6.1 2.3 39 7 44 165 9.7 0.3 10.6 9 06/22/2006 12:40:00 4.2 0.8 6.1 2.3 4.4 0.8 6.1 2.6 4.2 0.8 6.1 2.3 83 15 102 165 9.4 0 9.6 8.8 06/22/2006 12:50:00 4.1 0.7 5.7 2.3 4.4 0.7 5.7 2.6 4 0.7 5.7 2.3 88 8 99 165 9 0 9.3 8.8 06/22/2006 13:00:00 3 0.6 4.9 1.1 3.3 0.6 5.7 1.5 2.9 0.6 4.6 1.5 96 10 109 165 9 0.1 9.3 8.5 06/22/2006 13:10:00 1.9 0.8 3.8 0.4 2.2 0.7 3.8 0.4 1.8 0.7 3.4 0.4 54 20 32 165 9.5 0.1 9.6 9 06/22/2006 13:20:00 2.4 0.6 4.2 1.1 2.7 0.6 4.2 1.1 2.4 0.8 4.6 0.7 90 20 116 165 9.5 0 9.6 9 06/22/2006 13:30:00 1.7 0.5 3 0.4 2.1 0.4 3 1.1 1.8 0.6 3 0.4 106 20 106 165 9.6 0 9.6 9.3 06/22/2006 13:40:00 0.9 0.6 2.6 0.4 1.4 0.6 3 0.4 1 0.6 2.6 0.4 105 22 110 165 10 0.2 10.3 9.6 06/22/2006 13:50:00 1.1 0.6 2.6 0.4 1.5 0.6 3 0.4 1.2 0.7 2.6 0.4 117 22 133 165 10.5 0.2 10.9 9.8 06/22/2006 14:00:00 0.8 0.6 2.3 0.4 1.2 0.7 3 0.4 1 0.7 3 0.4 129 29 164 165 10.3 0.1 10.9 9.8 06/22/2006 14:10:00 1.5 0.6 3 0.4 1.9 0.5 3 0.7 1.7 0.6 3 0.4 119 22 141 165 10.5 0 10.9 10.3 06/22/2006 14:20:00 1.4 0.7 3 0.4 1.7 0.7 3 0.4 1.5 0.8 3 0.4 124 22 146 165 10.4 0 10.9 10.1 06/22/2006 14:30:00 1.4 0.5 2.3 0.4 1.8 0.4 2.6 0.7 1.6 0.4 2.6 0.4 116 16 131 165 10.5 0 10.9 10.3 06/22/2006 14:40:00 0.7 0.5 2.3 0.4 1.1 0.5 2.3 0.4 0.9 0.5 2.3 0.4 102 21 128 165 10.4 0 10.6 10.3 06/22/2006 14:50:00 0.9 0.5 2.6 0.4 1.3 0.6 2.6 0.4 1.3 0.6 2.6 0.4 111 15 127 165 10.5 0.1 10.9 10.1 06/22/2006 15:00:00 1.1 0.6 2.6 0.4 1.5 0.6 2.6 0.4 1.5 0.7 2.6 0.4 118 12 133 165 10.1 0.2 10.6 9.6 06/22/2006 15:10:00 2.6 0.7 4.2 0.7 2.8 0.7 4.2 1.1 2.7 0.6 4.2 1.5 119 8 121 165 10.1 0 10.3 9.8 06/22/2006 15:20:00 3.3 0.4 4.2 2.3 3.5 0.4 4.6 2.6 3.4 0.4 4.2 2.3 115 6 117 165 10 0 10.3 9.8 06/22/2006 15:30:00 3.5 0.5 4.6 1.9 3.8 0.5 4.9 2.3 3.6 0.5 4.6 1.9 111 6 114 165 10.2 0 10.6 10.1 06/22/2006 15:40:00 3.2 0.5 4.6 2.3 3.5 0.5 4.9 2.3 3.3 0.4 4.6 2.3 113 7 113 165 10.1 0 10.3 9.8 06/22/2006 15:50:00 4 0.4 5.3 3 4.3 0.4 5.3 3.4 4.1 0.4 5.3 3 108 7 106 165 10.2 0 10.6 9.8 06/22/2006 16:00:00 3.5 0.5 4.6 2.3 3.7 0.5 4.9 2.3 3.6 0.5 4.6 2.3 105 7 109 165 10 0 10.3 9.6 06/22/2006 16:10:00 1.9 0.6 3.4 0.4 2.3 0.5 3.8 0.7 2.3 0.5 4.6 0.7 102 11 101 165 10.1 0 10.6 9.6 06/22/2006 16:20:00 1.7 0.4 3 0.4 2.1 0.4 3.4 0.7 1.9 0.5 3 0.4 103 8 92 165 10.3 0 10.6 10.3 06/22/2006 16:30:00 1.8 0.6 3 0.4 2.1 0.5 3 0.7 1.9 0.6 3.4 0.4 97 22 102 165 10.1 0 10.3 9.8 06/22/2006 16:40:00 2.6 0.5 3.8 1.5 2.8 0.5 4.2 1.9 2.6 0.5 4.2 1.1 97 9 106 165 9.9 0.1 10.3 9.3 06/22/2006 16:50:00 2.7 0.4 3.8 1.5 2.9 0.4 4.2 1.9 2.8 0.4 3.8 1.5 100 7 99 165 9.6 0.1 10.1 9 06/22/2006 17:00:00 2.8 0.4 3.8 1.9 3.1 0.4 4.2 2.3 3 0.5 4.2 1.9 104 8 111 165 9.6 0.1 9.6 9 06/22/2006 17:10:00 2.8 0.4 3.8 1.9 3 0.4 4.2 2.3 3 0.4 3.8 2.3 110 7 96 165 9.6 0.1 9.6 9.3 06/22/2006 17:20:00 3.7 0.6 4.9 2.3 3.9 0.6 5.3 2.6 3.8 0.5 5.3 2.3 109 6 105 165 9.5 0 9.6 9.3 06/22/2006 17:30:00 3.2 0.6 4.6 1.5 3.4 0.6 4.9 1.9 3.3 0.5 4.9 1.9 95 9 101 165 9.1 0.1 9.6 8.8 06/22/2006 17:40:00 2.7 0.7 4.6 1.1 3 0.7 4.9 1.1 2.9 0.7 4.9 1.1 79 15 59 165 9.2 0.1 9.6 8.8 06/22/2006 17:50:00 2.4 0.6 3.8 1.1 2.6 0.5 4.2 1.5 2.5 0.6 4.2 1.1 64 20 64 165 9.5 0.2 9.8 9 06/22/2006 18:00:00 2.4 0.5 3.8 1.1 2.5 0.5 4.2 1.5 2.4 0.5 4.2 1.5 52 11 62 165 9.8 0 10.1 9.3 06/22/2006 18:10:00 1.7 0.5 2.6 0.4 1.9 0.4 3 0.4 1.8 0.5 2.6 0.4 43 12 39 165 9.8 0.1 10.1 9.3 06/22/2006 18:20:00 2.1 0.7 3.4 0.4 2.2 0.7 3.4 0.4 2 0.7 3.4 0.4 43 14 30 165 9.5 0.2 9.6 9 06/22/2006 18:30:00 2.2 0.4 3 1.1 2.4 0.4 3.4 1.5 2.2 0.5 3.4 0.7 92 13 88 165 9.5 0.2 9.8 9 06/22/2006 18:40:00 2.1 0.6 3.4 0.4 2.3 0.6 3.4 0.7 2.1 0.6 3.4 0.7 77 21 92 165 9.6 0.1 10.3 9.3 06/22/2006 18:50:00 1.5 0.6 3 0.4 1.7 0.6 3.4 0.4 1.6 0.5 3 0.4 79 19 92 165 9.4 0.1 9.8 9 06/22/2006 19:00:00 2 0.5 3 0.7 2.2 0.4 3.4 1.1 2.2 0.5 3.4 1.1 59 13 54 165 9.4 0.2 9.8 9 06/22/2006 19:10:00 2.3 0.6 3.8 1.1 2.3 0.6 3.8 0.7 2.4 0.5 3.8 1.5 45 16 39 165 9.2 0.3 9.6 8.5 06/22/2006 19:20:00 1.5 0.7 3.4 0.4 1.3 0.9 3.4 0.4 1.4 0.8 3.8 0.4 57 17 41 165 9.2 0.3 9.6 8.8 06/22/2006 19:30:00 1.5 1.3 4.2 0.4 1.4 1.3 4.2 0.4 1.4 1.2 3.8 0.4 62 35 16 165 9.5 0.2 10.1 9 06/22/2006 19:40:00 3 0.7 4.6 0.7 3.1 0.7 4.6 0.7 3.2 0.7 4.6 1.1 44 19 51 165 9.1 0.1 9.8 8.5 06/22/2006 19:50:00 3.6 0.9 5.3 1.5 3 1 5.3 1.1 3.7 0.8 5.7 1.5 13 11 21 165 9 0 9.3 8.8 06/22/2006 20:00:00 3.5 0.5 4.6 1.9 3.2 0.6 4.6 1.5 3.6 0.5 4.6 2.6 16 8 12 165 8.9 0 9 8.8 06/22/2006 20:10:00 3.1 0.6 4.6 1.9 2.9 0.8 4.6 1.1 3.3 0.6 4.9 1.9 17 11 10 165 8.9 0 9 8.5 06/22/2006 20:20:00 3.4 0.6 4.9 1.5 2.8 0.8 4.6 1.5 3.5 0.6 4.6 1.9 15 12 15 165 8.9 0 9 8.5 06/22/2006 20:30:00 3.5 0.5 4.9 1.9 2.9 0.7 4.6 1.1 3.6 0.5 4.9 1.9 13 8 7 165 8.9 0 9 8.5 06/22/2006 20:40:00 3.7 0.5 4.9 2.6 3.3 0.8 4.6 1.1 3.9 0.5 5.3 2.6 16 9 21 165 8.7 0 8.8 8.3 06/22/2006 20:50:00 4 0.5 5.7 2.6 3.7 0.5 5.3 1.9 4.1 0.5 5.3 3 19 8 21 165 8.6 0 8.8 8.3 06/22/2006 21:00:00 4.6 0.6 6.5 3 4.6 0.7 6.5 2.6 4.7 0.6 6.5 3.4 25 8 35 165 8.5 0.1 8.5 7.8 06/22/2006 21:10:00 4.4 0.5 5.7 3 4.4 0.6 5.7 2.6 4.7 0.5 6.1 3.4 23 7 29 165 8.3 0 8.5 7.8 06/22/2006 21:20:00 4.4 0.4 5.7 3.8 4.1 0.7 5.3 1.9 4.6 0.4 5.3 3.8 18 7 23 165 8.2 0 8.3 7.5 06/22/2006 21:30:00 3.9 0.3 4.6 3.4 4 0.3 4.9 3.4 4.2 0.2 4.9 3.4 23 2 20 165 8.2 0 8.3 8 06/22/2006 21:40:00 4.3 0.3 5.3 3.4 4.4 0.4 5.3 3.4 4.6 0.3 5.3 3.8 23 4 21 165 8.1 0 8.3 8 06/22/2006 21:50:00 4.6 0.3 5.3 3.8 4 0.7 5.3 2.3 4.9 0.3 5.7 4.2 14 4 15 165 8.1 0 8.5 8 06/22/2006 22:00:00 4.1 0.2 4.9 3.8 3.4 0.6 4.6 1.9 4.4 0.3 4.9 3.8 13 3 15 165 8 0.1 8.5 8 06/22/2006 22:10:00 3.9 0.3 4.6 3.4 3.1 0.7 4.6 1.5 4.1 0.3 4.9 3.4 12 4 14 165 8 0 8 7.8 06/22/2006 22:20:00 4.5 0.3 5.3 3.8 3.6 0.7 4.9 1.9 4.7 0.3 5.7 3.8 13 3 15 165 8 0 8 7.8 06/22/2006 22:30:00 4.4 0.3 4.9 3.8 3 0.7 4.9 1.5 4.7 0.3 5.3 4.2 8 4 16 165 8 0 8.5 7.5 06/22/2006 22:40:00 3.9 0.2 4.6 3.4 2.1 0.3 3 1.1 4.2 0.3 4.9 3.8 2 3 3 165 7.8 0 8.5 7.5 06/22/2006 22:50:00 4 0.3 4.9 3.4 2.1 0.4 3.4 1.5 4.3 0.3 4.9 3.8 359 3 3 165 7.7 0 7.8 7.3 06/22/2006 23:00:00 4.8 0.3 5.7 4.2 2.7 0.5 4.2 1.5 5 0.4 6.1 4.2 5 4 3 165 7.8 0.1 8.3 7.3 06/22/2006 23:10:00 4.8 0.5 6.5 3.4 3 0.9 5.7 1.5 4.9 0.5 6.5 3.8 3 6 7 165 8 0 8.3 7.8 06/22/2006 23:20:00 4.6 0.5 5.7 3.4 3.3 0.8 5.3 1.5 4.7 0.4 5.7 3.8 356 6 4 165 8 0 8.3 7.5 06/22/2006 23:30:00 5 0.5 6.5 4.2 3.5 0.9 6.1 1.9 5 0.5 6.5 3.8 0 7 18 165 8.1 0 8.5 7.8 06/22/2006 23:40:00 5.3 0.4 6.1 4.2 3.1 0.6 5.3 1.5 5.4 0.4 6.5 4.2 3 5 3 165 8.3 0 8.5 8 06/22/2006 23:50:00 4.7 0.4 6.1 3.8 3.1 0.8 4.9 1.9 4.7 0.5 6.1 3.4 358 6 355 165 8.4 0 8.5 8 06/23/2006 00:00:00 3.7 0.3 4.6 3 3.7 0.5 4.6 1.5 3.8 0.4 4.9 2.6 344 6 353 165 8.2 0 8.5 7.8 06/23/2006 00:10:00 3.6 0.7 5.7 2.3 3.6 0.6 5.7 1.9 3.6 0.5 5.3 2.3 335 9 349 165 8.2 0 8.5 7.8 06/23/2006 00:20:00 3.7 0.6 5.7 2.3 3.7 0.6 5.7 2.3 3.6 0.6 5.7 1.5 331 9 351 165 8.3 0 8.5 8 06/23/2006 00:30:00 3.7 0.9 6.1 2.3 3.8 0.9 6.1 2.3 3.6 0.8 6.1 1.9 340 6 336 165 8.3 0 8.5 7.8 06/23/2006 00:40:00 5.3 0.6 6.8 3.8 5.1 0.7 6.8 3 5.1 0.6 6.8 3.4 343 8 350 165 8.3 0 8.5 7.8 06/23/2006 00:50:00 4.4 0.7 6.1 2.6 4.4 0.7 5.7 2.6 4.3 0.6 5.7 3 336 8 338 165 8.3 0 8.5 8.3 06/23/2006 01:00:00 4.4 0.4 5.7 3.4 4.1 0.8 6.1 1.5 4.3 0.4 5.7 3 344 9 350 165 8.3 0 8.5 8.3 06/23/2006 01:10:00 5 0.8 7.2 3.4 4.9 0.9 7.2 2.6 4.9 0.7 6.8 3.4 345 6 352 165 8.3 0 8.5 8.3 06/23/2006 01:20:00 5 1 9.1 2.6 4.8 1.2 9.1 2.3 4.8 1 8.8 2.3 342 10 344 165 8.1 0 8.3 8 06/23/2006 01:30:00 5.8 0.8 7.6 3.8 5.1 1.1 7.6 2.6 5.1 0.9 8 3 351 9 0 165 8.3 0 8.5 8 06/23/2006 01:40:00 7.2 3.1 13.7 3.4 6 2.8 13.7 2.3 6.9 2.8 13.3 3.8 6 10 7 165 8.4 0 8.5 8.3 06/23/2006 01:50:00 7.9 2 13 4.6 7.5 1.8 12.2 4.2 7.3 1.9 13.3 3.4 23 13 14 165 8.7 0 8.8 8.5 06/23/2006 02:00:00 6.9 1.2 9.9 3.8 6.8 1.3 10.3 3.8 6.5 1.2 8.8 3.8 33 17 36 165 8.7 0 8.8 8.5 06/23/2006 02:10:00 7.4 1 9.9 4.9 7.6 1.1 10.3 4.9 7.2 0.8 9.5 4.9 65 8 56 165 8.1 0.1 8.5 7.8 06/23/2006 02:20:00 7.2 1.1 9.1 4.9 7.4 1.1 9.5 4.9 7 1.1 9.1 4.2 69 7 71 165 7.8 0 7.8 7.8 06/23/2006 02:30:00 6.1 0.9 8.4 4.2 6.3 0.9 8.4 4.2 5.8 0.8 8.4 4.2 79 7 73 165 7.6 0 7.8 7.5 06/23/2006 02:40:00 5.5 0.8 7.2 3.8 5.6 0.8 7.6 3.8 5.2 0.7 7.6 3.4 61 12 60 165 7.8 0.1 8 7.5 06/23/2006 02:50:00 5.9 1 8.8 3.4 6.1 1 9.1 3.4 5.8 0.8 8 3.8 63 9 68 165 8.1 0 8.3 7.8 06/23/2006 03:00:00 5.8 1.3 9.1 3 5.8 1.3 9.5 3 5.5 1.2 8.8 3 55 12 58 165 8.3 0 8.5 7.8 06/23/2006 03:10:00 6.5 1.5 9.5 2.6 6.6 1.5 9.9 2.6 6.3 1.3 9.5 3.4 57 9 36 165 8.2 0.1 8.5 7.5 06/23/2006 03:20:00 7.9 1 9.9 4.9 8 1 10.3 4.6 7.4 1 9.9 4.6 61 7 74 165 8 0.1 8.3 7.3 06/23/2006 03:30:00 7.8 0.9 10.3 5.7 8 0.9 10.7 5.7 7.5 1 9.9 4.6 65 10 70 165 7.9 0 8 7.5 06/23/2006 03:40:00 5.1 1.9 9.9 2.3 5.2 1.9 10.3 2.3 5.1 1.7 9.5 2.3 55 21 61 165 8 0 8.3 7.5 06/23/2006 03:50:00 5.3 1 8 3 4.9 1 8 2.6 4.9 0.9 8 3 21 14 20 165 8.1 0 8.3 7.5 06/23/2006 04:00:00 5.5 1 8 2.6 5.3 1.2 8 2.3 5.4 1 8.4 3 26 12 36 165 8 0.1 8.3 7.5 06/23/2006 04:10:00 4.9 0.8 6.5 2.6 4.7 1 6.5 1.5 4.8 0.9 6.8 2.6 24 9 44 165 8 0.1 8.3 7.5 06/23/2006 04:20:00 5.5 0.7 6.8 3 5.1 0.6 6.5 3.4 5.5 0.7 6.8 3.4 20 6 18 165 7.9 0.1 8 7.3 06/23/2006 04:30:00 6.2 0.8 8 3.8 5.9 0.9 7.6 3.4 6.1 0.8 8 4.2 24 8 19 165 7.8 0 7.8 7.3 06/23/2006 04:40:00 5.8 0.7 7.6 4.2 5.7 0.8 7.6 3.8 5.6 0.6 7.2 3.8 24 7 27 165 7.7 0 7.8 7.3 06/23/2006 04:50:00 5.8 0.7 7.2 3.8 5.6 0.9 7.6 2.6 5.6 0.6 7.2 3.8 23 7 32 165 7.7 0 7.8 7.3 06/23/2006 05:00:00 5.9 0.7 7.6 4.2 5.7 0.8 7.6 3.4 5.6 0.7 7.2 4.2 23 7 23 165 7.7 0 8 7.3 06/23/2006 05:10:00 6.1 0.7 8 4.2 6 0.7 8.4 3.8 6 0.7 8.4 4.2 25 6 31 165 7.7 0 7.8 7.3 06/23/2006 05:20:00 6.6 0.7 8 4.9 6.2 0.8 8 3.4 6.5 0.7 8 4.9 20 6 23 165 7.7 0 7.8 7.5 06/23/2006 05:30:00 6.9 0.7 8.8 4.6 6.1 1 8 3.4 6.7 0.8 8.8 4.9 15 7 16 165 7.8 0 8 7.8 06/23/2006 05:40:00 7 0.8 9.1 4.9 5.9 1 8 3 6.9 0.9 9.5 4.6 13 6 18 165 7.9 0 8 7.8 06/23/2006 05:50:00 6.7 0.8 9.1 4.6 5.4 1 8.4 3 6.5 0.9 8.8 4.2 10 7 8 165 8 0 8 7.8 06/23/2006 06:00:00 7.4 0.9 9.5 5.3 5.9 1.2 8.8 3 7.3 0.8 9.9 4.9 10 7 16 165 8 0 8.3 7.8 06/23/2006 06:10:00 7.1 0.7 8.8 4.9 5.7 1 8 3.4 7.1 0.7 9.5 5.3 11 6 10 165 8 0 8.3 8 06/23/2006 06:20:00 6.9 0.7 8.8 5.3 4.9 0.9 7.6 3 6.9 0.8 8.8 4.9 5 6 1 165 8.1 0 8.3 8 06/23/2006 06:30:00 7.1 0.8 9.1 5.3 4.9 1 8 2.6 6.9 0.8 9.1 4.9 5 6 1 165 8.2 0 8.3 8 06/23/2006 06:40:00 6.8 1.1 9.9 3.8 5.5 1.3 9.5 2.6 6.6 1.2 9.5 4.2 9 9 16 165 8.1 0 8.3 8 06/23/2006 06:50:00 8.1 1.4 11.5 4.9 6.6 1.5 10.7 3.4 7.9 1.4 11.1 4.9 8 8 5 165 8.1 0 8.3 8 06/23/2006 07:00:00 8.2 1 10.3 5.3 6.5 1.2 9.9 3.8 8 1 10.3 5.7 7 8 28 165 8.3 0 8.5 8.3 06/23/2006 07:10:00 8.5 1.1 11.5 6.1 6.6 1.3 9.9 3 8.2 1.1 10.7 5.7 7 7 18 165 8.5 0 8.5 8.3 06/23/2006 07:20:00 8.5 1.1 11.5 5.3 7 1.4 10.3 3 8.2 1.2 11.5 5.3 9 8 11 165 8.5 0 8.8 8.5 06/23/2006 07:30:00 8.3 1 11.1 5.7 6.9 1.3 10.3 3.8 8.2 1 10.7 5.3 10 8 22 165 8.6 0 8.8 8.5 06/23/2006 07:40:00 9.4 1.2 13 6.1 7.4 1.5 11.8 4.6 9.2 1.3 13 6.1 8 9 12 165 8.5 0 8.8 8.3 06/23/2006 07:50:00 8.9 1 12.2 6.5 6.5 1.5 11.5 3.4 8.5 1.1 11.5 5.7 3 7 12 165 8.5 0.1 8.5 8.3 06/23/2006 08:00:00 8.7 0.9 11.1 6.5 6.5 1.2 10.3 3.8 8.3 1 11.5 6.1 5 8 9 165 8.6 0 8.8 8.3 06/23/2006 08:10:00 9.1 1.3 12.6 5.7 7.2 1.4 10.7 3 8.8 1.4 11.5 4.9 7 9 7 165 8.7 0 8.8 8.5 06/23/2006 08:20:00 9.3 1.3 12.6 5.7 7.3 1.1 11.5 4.6 9.2 1.4 12.6 5.3 7 8 348 165 8.7 0 8.8 8.3 06/23/2006 08:30:00 8.7 1.2 11.5 6.5 7.6 1.3 11.1 4.6 8.5 1.2 12.2 6.1 12 7 12 165 8.7 0 8.8 8.3 06/23/2006 08:40:00 9.4 1.1 12.2 6.5 8.4 1.3 11.8 5.3 9.2 1.1 12.2 4.9 13 6 23 165 8.7 0 8.8 8.3 06/23/2006 08:50:00 9.8 1 12.2 6.8 8.9 1.4 12.2 4.9 9.3 1.2 12.2 6.1 14 7 21 165 8.9 0 9 8.5 06/23/2006 09:00:00 10.9 1.3 14.1 7.6 10.5 1.5 13.7 6.5 10.4 1.5 13.7 6.5 20 8 12 165 8.7 0 9.3 8.5 06/23/2006 09:10:00 9.8 1.2 12.6 6.1 9.1 1.4 12.2 5.7 9.5 1.2 13.3 6.5 16 8 19 165 8.8 0 9 8.5 06/23/2006 09:20:00 9.3 1.3 12.6 6.1 8.8 1.5 11.8 4.9 9.3 1.3 12.2 6.5 17 7 12 165 8.8 0 9 8.5 06/23/2006 09:30:00 10.2 1.3 13.7 6.5 9.7 1.4 13.7 5.7 9.7 1.3 12.6 6.8 19 8 27 165 9 0 9.3 8.8 06/23/2006 09:40:00 11.3 1.2 14.9 7.6 10.8 1.3 14.9 6.8 10.9 1.3 14.1 7.6 20 7 18 165 9 0 9.3 8.8 06/23/2006 09:50:00 11.4 1.3 14.1 7.6 10.9 1.5 13.7 6.1 10.8 1.3 13.7 7.2 19 7 21 165 8.9 0 9 8.5 06/23/2006 10:00:00 10.8 1.5 14.9 7.2 10.3 1.6 14.5 6.1 10.4 1.4 14.1 6.8 19 8 25 165 8.7 0 9 8.5 06/23/2006 10:10:00 10.8 1.4 14.9 7.2 10.3 1.7 14.5 6.1 10.3 1.5 14.5 6.5 19 8 16 165 8.5 0 8.8 8.5 06/23/2006 10:20:00 10 1.2 12.6 6.5 9.1 1.5 12.6 4.9 9.5 1.3 13.3 6.8 15 8 15 165 8.5 0 8.8 8.5 06/23/2006 10:30:00 11.1 1.3 13.7 6.5 10.5 1.5 13.7 6.1 10.5 1.3 13.7 7.6 18 8 22 165 8.6 0 8.8 8.5 06/23/2006 10:40:00 10.7 1.3 14.1 7.2 9.8 1.5 13.7 6.1 10.2 1.3 14.1 7.2 16 8 18 165 8.7 0 9 8.5 06/23/2006 10:50:00 11.4 1.6 16.1 7.2 10.5 1.7 15.6 5.3 11 1.7 15.3 6.8 16 8 18 165 8.9 0 9 8.8 06/23/2006 11:00:00 11.5 1.6 15.6 7.2 11 1.7 14.9 6.5 11.1 1.5 14.9 6.8 21 8 24 165 9 0 9.3 8.8 06/23/2006 11:10:00 11.6 1.6 15.3 7.2 11.3 1.7 15.3 6.1 11.3 1.7 14.9 6.8 23 9 30 165 9 0 9.3 9 06/23/2006 11:20:00 13 1.7 16.4 7.6 12.7 1.8 16.8 7.6 12.6 1.9 16.8 8.4 22 7 29 165 9 0 9.3 8.8 06/23/2006 11:30:00 12.2 1.9 16.1 6.8 11.9 2 16.1 6.5 11.5 2 15.6 6.1 22 9 23 165 9 0 9 9 06/23/2006 11:40:00 11.3 2.2 16.4 6.8 11.1 2.2 16.8 6.8 10.8 2.1 16.4 6.1 27 10 26 165 8.8 0 9 8.5 06/23/2006 11:50:00 9.9 1.6 14.1 5.7 9.8 1.7 13.7 5.7 9.4 1.5 13.3 6.1 34 10 25 165 8.5 0 8.8 8.5 06/23/2006 12:00:00 10.9 1.5 14.1 6.5 10.9 1.6 14.5 5.7 10.9 1.6 14.9 6.1 34 9 36 165 8.5 0 8.8 8.5 06/23/2006 12:10:00 9.2 1.3 13.3 6.1 9.3 1.3 13.3 6.1 8.9 1.4 13.7 5.3 41 12 26 165 8.2 0 8.5 7.8 06/23/2006 12:20:00 9.2 1.8 14.5 4.9 9 1.8 14.9 5.3 8.8 1.9 15.3 4.6 30 13 27 165 8.7 0.1 9 8 06/23/2006 12:30:00 10.9 1.5 15.3 7.6 10.5 1.6 14.5 6.1 10.8 1.5 14.5 7.2 23 8 16 165 9.2 0 9.3 8.8 06/23/2006 12:40:00 9.6 1.3 12.6 5.3 9.4 1.3 12.6 5.3 9.1 1.3 13 4.6 25 8 29 165 9.1 0.1 9.3 8.8 06/23/2006 12:50:00 9.1 1.1 11.8 6.1 8.9 1.1 11.5 5.7 8.8 1.1 11.8 5.7 25 8 26 165 8.9 0 9.3 8.5 06/23/2006 13:00:00 9.1 1.5 12.6 4.9 9 1.5 12.2 4.2 8.8 1.5 12.6 5.3 27 9 16 165 9.2 0 9.3 8.8 06/23/2006 13:10:00 9.6 1.3 13 6.5 9.4 1.4 12.6 6.1 9 1.4 13 5.7 25 10 28 165 9.4 0 9.8 9 06/23/2006 13:20:00 9.6 1.6 13.3 6.1 9.4 1.7 13.3 4.9 9.2 1.7 13.3 5.7 25 10 34 165 9.2 0 9.8 8.8 06/23/2006 13:30:00 9.8 1.3 13 6.8 9.5 1.4 13 6.5 9.3 1.5 13.3 6.1 22 9 16 165 9.1 0.1 9.8 8.5 06/23/2006 13:40:00 9.6 1.5 13.3 5.3 9.3 1.5 13 5.7 9.3 1.5 13 6.1 23 9 28 165 9.1 0 9.3 9 06/23/2006 13:50:00 9.8 1.3 12.6 6.1 9.5 1.5 13 6.1 9.5 1.4 13 6.8 23 9 28 165 9.1 0 9.3 8.5 06/23/2006 14:00:00 10.7 1.6 13.7 6.1 10.3 1.7 13.7 5.7 10.1 1.7 13.7 5.7 20 8 15 165 9 0 9.3 8.5 06/23/2006 14:10:00 7.5 1.9 11.8 3.4 7.3 1.8 11.8 3.8 7.1 1.8 11.1 3.4 33 15 16 165 9 0 9 8.8 06/23/2006 14:20:00 7 1.8 12.2 3 7.1 1.8 12.6 3 6.9 1.7 11.8 3.8 59 13 70 165 8.8 0 9 8.5 06/23/2006 14:30:00 6.4 1.6 11.1 2.6 6.5 1.7 11.1 3 6.2 1.6 10.3 2.3 55 11 57 165 8.8 0 9.3 8.8 06/23/2006 14:40:00 5.2 1.3 9.9 2.6 5.4 1.2 9.9 3 5.3 1.1 9.1 3.4 52 13 50 165 8.9 0 9 8.8 06/23/2006 14:50:00 5.5 1.3 8.8 2.3 5.6 1.4 8.8 2.3 5.5 1.3 8.8 2.6 52 16 70 165 9 0 9 9 06/23/2006 15:00:00 6.3 1.6 10.3 3 6.4 1.6 10.7 3 6.1 1.4 9.9 3.4 60 16 53 165 9 0.1 9.6 8.5 06/23/2006 15:10:00 5.2 1.2 9.1 3 5.3 1.2 9.1 3 5.3 1.2 8.8 3 54 15 49 165 9 0.1 9.3 8.5 06/23/2006 15:20:00 6.3 1.5 9.9 3 6.4 1.5 10.3 2.6 6.2 1.2 9.9 3.4 62 13 63 165 9 0.1 9.3 8.5 06/23/2006 15:30:00 6.2 1.5 9.9 3 6.4 1.5 10.3 3.4 6.2 1.5 10.3 3.4 61 15 78 165 9.2 0.1 9.6 8.5 06/23/2006 15:40:00 6.2 1.5 9.1 3 6.3 1.5 9.1 2.6 6.2 1.5 9.5 2.6 60 18 43 165 9.5 0 9.8 9 06/23/2006 15:50:00 6.2 1.7 11.1 2.3 6.3 1.8 11.5 2.6 6.1 1.8 11.1 2.6 56 17 68 165 9.5 0.1 9.8 9 06/23/2006 16:00:00 6.8 1.7 11.5 3.4 6.9 1.8 11.8 3 6.9 1.7 11.5 3.8 58 19 55 165 9.4 0 9.8 8.8 06/23/2006 16:10:00 6.7 1.4 10.3 3 6.9 1.4 10.7 3.8 6.6 1.4 10.3 3 59 12 52 165 9.1 0.1 9.3 8.8 06/23/2006 16:20:00 7.9 1.7 11.5 3.8 8.1 1.7 11.8 4.2 7.7 1.7 12.2 3.8 62 12 81 165 9 0 9.3 8.8 06/23/2006 16:30:00 7.3 1.5 11.5 4.2 7.5 1.5 11.1 4.2 7.2 1.4 11.5 3.4 62 11 52 165 9 0.2 9.3 8.5 06/23/2006 16:40:00 7.1 1.2 9.9 3.8 7.3 1.2 9.9 3.8 7 1.2 9.9 3.8 64 10 76 165 8.7 0 9 8.3 06/23/2006 16:50:00 7.4 1.2 11.1 4.2 7.6 1.3 11.5 4.9 7.4 1.2 11.1 4.2 64 10 59 165 8.8 0 9 8.5 06/23/2006 17:00:00 7.3 1.3 10.7 4.2 7.4 1.3 10.7 4.6 7.2 1.2 10.3 4.2 62 10 57 165 9 0 9.3 8.5 06/23/2006 17:10:00 6.9 1.3 10.3 4.2 7.1 1.3 10.7 4.6 6.8 1.2 10.3 4.6 59 9 65 165 9.2 0.2 9.6 8.5 06/23/2006 17:20:00 7.4 1.3 10.3 3.4 7.6 1.3 10.7 3.4 7.5 1.2 11.1 3.8 61 9 64 165 9.1 0.2 9.3 8.5 06/23/2006 17:30:00 8.2 1.2 10.7 5.3 8.4 1.2 11.1 5.3 8.2 1.1 10.7 5.3 59 8 54 165 8.8 0 9 8.3 06/23/2006 17:40:00 8 1 10.7 5.7 8.1 1 11.1 5.7 7.8 1.1 10.7 4.9 62 8 61 165 8.9 0 9.3 8.3 06/23/2006 17:50:00 7.2 1.2 9.5 4.2 7.3 1.2 9.9 4.2 7.1 1.1 9.1 4.6 58 9 64 165 9 0 9 8.5 06/23/2006 18:00:00 6.7 1.3 10.3 3.8 6.8 1.4 10.7 3.8 6.6 1.2 9.5 3.8 53 10 54 165 8.9 0 9 8.5 06/23/2006 18:10:00 5.3 1.5 9.9 2.3 5.4 1.6 9.9 2.6 5.4 1.4 9.5 2.3 49 15 56 165 8.7 0 9 8.5 06/23/2006 18:20:00 5.7 1.7 11.1 2.6 5.7 1.7 10.7 2.6 5.6 1.5 11.1 3 37 17 16 165 8.5 0 8.8 8.5 06/23/2006 18:30:00 8.6 1.2 11.5 5.3 8.2 1.3 11.5 4.9 8.1 1.2 11.5 5.3 19 8 19 165 8.5 0 8.5 8.3 06/23/2006 18:40:00 9.3 1.2 11.8 6.1 8.6 1.3 11.8 4.9 8.9 1.3 11.8 5.3 17 8 18 165 8.5 0 8.5 8.3 06/23/2006 18:50:00 8.6 1.2 11.1 5.3 8 1.3 11.1 4.6 8.4 1.2 11.5 5.3 17 8 23 165 8.4 0 8.5 8 06/23/2006 19:00:00 8.1 1.1 10.3 4.9 7.5 1.2 9.9 4.6 8 1 11.1 5.7 17 8 23 165 8.2 0 8.5 8 06/23/2006 19:10:00 9 1.1 11.5 5.7 8.5 1.2 11.1 5.3 8.9 1.1 11.5 6.5 18 7 19 165 8 0 8.3 8 06/23/2006 19:20:00 8.3 1.2 11.1 4.9 8 1.3 11.5 4.9 8.1 1.2 11.5 5.3 21 8 11 165 8 0 8 7.8 06/23/2006 19:30:00 7.6 1 9.9 4.9 7.5 1 9.9 4.9 7.4 1.1 10.3 4.2 25 9 32 165 8 0 8.3 7.8 06/23/2006 19:40:00 8.5 1.1 11.1 5.7 8.2 1.2 11.1 5.3 8.2 1.2 11.5 5.3 26 9 20 165 8 0 8 8 06/23/2006 19:50:00 9 1 11.1 5.7 8.8 1.2 11.1 5.3 8.8 1.1 11.5 5.3 22 6 17 165 8 0 8 7.8 06/23/2006 20:00:00 8.6 1.2 11.1 5.7 8.2 1.4 11.1 3.4 8.4 1.3 11.1 5.3 20 7 22 165 7.9 0 8 7.8 06/23/2006 20:10:00 7.1 1.1 9.9 4.6 6.9 1.1 9.9 4.2 6.9 1 9.9 4.6 23 9 32 165 7.8 0 8 7.8 06/23/2006 20:20:00 6.9 1 9.5 4.9 6.8 1 9.9 4.6 6.7 1 9.5 4.2 25 8 34 165 7.8 0 8 7.8 06/23/2006 20:30:00 7.7 1.2 9.9 4.9 7.5 1.2 9.9 4.2 7.4 1.4 9.9 4.2 24 8 26 165 7.8 0 8 7.8 06/23/2006 20:40:00 6.5 1 9.1 3.8 6.5 1 8.8 3.8 6.5 1 9.1 3 39 9 36 165 8 0 8 7.8 06/23/2006 20:50:00 5.9 0.7 8 4.2 5.9 0.7 8 4.2 5.9 0.7 7.6 3.8 42 8 25 165 8 0 8.3 7.8 06/23/2006 21:00:00 6.3 0.9 8.8 3.8 6.3 0.9 9.1 3.8 6.1 0.9 8.8 4.2 41 12 29 165 8 0 8.3 8 06/23/2006 21:10:00 7.1 1 9.5 4.2 7.2 1 9.5 4.2 6.8 1 9.9 4.6 54 7 53 165 8.1 0 8.3 7.8 06/23/2006 21:20:00 7.4 1.3 10.7 4.2 7.5 1.3 11.5 4.2 7 1.2 10.3 4.2 52 9 50 165 8.1 0 8.3 7.5 06/23/2006 21:30:00 5.4 1.2 8.4 2.6 5.4 1.2 8.8 2.6 5.2 1.1 9.1 3 54 11 52 165 8.3 0 8.5 7.5 06/23/2006 21:40:00 5.3 1 8 3 5.4 1 8.4 3 5.2 1 8.8 2.6 55 12 73 165 8.3 0 8.5 7.8 06/23/2006 21:50:00 7 1.3 10.7 4.2 7.1 1.4 11.1 4.2 6.6 1.5 10.3 3.4 59 11 57 165 8.3 0 8.5 7.8 06/23/2006 22:00:00 6.9 1.3 10.3 3.8 7.1 1.3 10.7 3.8 6.7 1.2 10.3 3.8 67 10 53 165 8.3 0 8.5 7.8 06/23/2006 22:10:00 6.7 1.1 9.9 3.8 6.9 1.1 10.3 4.2 6.6 0.9 9.1 4.2 74 9 75 165 8.3 0 8.5 7.8 06/23/2006 22:20:00 6.7 1.3 9.9 3.8 6.9 1.3 10.3 4.2 6.6 1.1 9.1 3.8 73 9 78 165 8.2 0 8.3 7.5 06/23/2006 22:30:00 5.8 1.2 9.1 3.8 6 1.2 9.5 3.8 5.8 1 8.8 3.8 66 10 75 165 8.1 0 8.3 7.5 06/23/2006 22:40:00 6.3 0.9 8.4 3.8 6.4 1 8.8 3.8 6.2 0.9 8.4 4.2 57 9 65 165 8.1 0 8.3 7.5 06/23/2006 22:50:00 5.5 1 7.6 3 5.6 1 8 3 5.5 1 7.6 3 56 12 73 165 8.1 0 8.3 7.5 06/23/2006 23:00:00 5.7 1.1 8.4 3 5.9 1.2 8.8 3 5.5 1 7.6 3 62 11 60 165 8.1 0 8.3 7.5 06/23/2006 23:10:00 6.1 0.8 8 3.8 6.3 0.8 8 3.4 5.9 0.8 8 3.4 70 9 80 165 8 0 8.3 7.5 06/23/2006 23:20:00 6.2 1.1 9.1 3.8 6.3 1.1 9.5 3.8 6.1 1 8.8 4.2 66 11 55 165 8.2 0 8.3 7.5 06/23/2006 23:30:00 6.5 1.2 9.5 3.8 6.7 1.3 9.9 3.8 6.5 1.1 9.5 4.2 64 8 61 165 8.2 0 8.3 7.5 06/23/2006 23:40:00 5.3 1.2 8.4 3 5.4 1.3 8.8 2.6 5.3 1.1 8 2.6 56 10 67 165 8.3 0 8.5 8.3 06/23/2006 23:50:00 4.2 0.9 7.6 2.3 4.3 0.9 7.6 2.6 4.2 0.8 6.8 1.9 63 15 43 165 8.3 0 8.5 8.3 06/24/2006 00:00:00 6 1 8.8 3.4 6.1 1 8.8 3.8 5.8 1 8.4 3 60 12 60 165 8.2 0.1 8.8 8 06/24/2006 00:10:00 7.2 1.3 10.3 3.8 7.3 1.3 10.7 3.8 7 1.2 10.3 4.2 58 11 52 165 8.1 0.1 8.3 8 06/24/2006 00:20:00 6.6 1.1 9.1 4.2 6.7 1.1 9.1 3.8 6.5 1 8.8 3.8 50 9 50 165 8 0 8 7.8 06/24/2006 00:30:00 4.8 1.1 7.6 2.3 5 1.1 7.6 2.3 4.9 1.1 7.2 2.6 47 10 36 165 8 0 8.3 7.8 06/24/2006 00:40:00 5.2 1 7.6 3.4 5.3 1 8 3.4 5.2 0.9 8 3.4 51 9 52 165 8.1 0 8.3 8 06/24/2006 00:50:00 5.2 1 8 3 5.2 1 8 3 5 0.9 8.4 3 45 9 37 165 8.2 0 8.3 8.3 06/24/2006 01:00:00 6.4 0.9 8 3.8 6.4 0.9 8.4 3.8 6.2 1 8.4 3.8 45 8 39 165 8.3 0 8.8 8.3 06/24/2006 01:10:00 5.9 0.8 8 4.2 5.9 0.8 8.4 4.2 5.7 0.8 8.4 3.4 38 7 37 165 8.3 0 8.5 8.3 06/24/2006 01:20:00 5.9 1.1 9.1 3 5.8 1.2 9.1 3.4 5.8 1.2 9.1 3.4 30 10 23 165 8.3 0 8.5 8.3 06/24/2006 01:30:00 6.3 1.1 8.8 3.8 6.2 1.1 8.8 3.8 6.2 1.2 9.1 3.8 29 9 25 165 8.1 0 8.3 8 06/24/2006 01:40:00 6.2 1 9.1 4.2 5.9 1 9.1 3.4 6.1 0.9 8.8 4.2 24 9 26 165 8 0 8.3 8 06/24/2006 01:50:00 6.9 1.2 9.9 4.2 6.5 1.2 9.5 3.8 6.7 1.2 9.5 4.2 19 7 16 165 8 0.1 8.3 7.3 06/24/2006 02:00:00 7.7 0.9 9.9 5.3 7.4 1 9.5 4.6 7.4 1 9.9 4.9 21 6 15 165 8 0.1 8.3 7.3 06/24/2006 02:10:00 7.5 0.8 9.5 4.9 7.3 0.9 9.5 4.9 7.3 0.8 9.1 5.3 23 6 32 165 8 0.1 8.3 7.5 06/24/2006 02:20:00 7 0.7 8.8 5.3 6.5 1 9.1 3.4 6.8 0.8 8.8 4.6 19 8 22 165 8 0.1 8.3 7.3 06/24/2006 02:30:00 7.4 0.9 9.9 5.3 6.5 1.1 9.9 3.8 7.2 1 10.3 4.9 14 8 10 165 8 0.1 8.3 7.3 06/24/2006 02:40:00 8 1 10.7 5.3 7.2 1.2 10.3 4.2 7.8 1 10.7 5.7 16 7 17 165 7.9 0 8 7.3 06/24/2006 02:50:00 7 0.9 9.1 4.2 6.5 1.1 9.1 3 6.9 0.9 9.1 4.6 18 7 11 165 7.7 0 7.8 7.3 06/24/2006 03:00:00 7.8 0.7 9.9 5.7 7.3 0.8 9.5 4.9 7.6 0.8 10.3 5.3 19 6 23 165 7.7 0 8 7.5 06/24/2006 03:10:00 8.4 1 11.1 5.7 7.6 1.3 10.7 4.2 8.1 1.1 11.5 5.3 16 7 8 165 7.8 0 7.8 7.5 06/24/2006 03:20:00 8 0.9 10.7 6.1 7.2 1.2 10.7 4.2 7.7 1 10.7 5.3 15 7 26 165 7.8 0 8 7.3 06/24/2006 03:30:00 7.8 1 10.7 5.3 7.1 1.2 10.3 3.8 7.5 0.9 9.9 5.3 17 9 22 165 7.9 0 8 7.3 06/24/2006 03:40:00 7.8 0.9 10.3 5.7 7.2 1.1 10.3 4.2 7.6 0.9 10.3 5.3 17 8 15 165 8 0.1 8.3 7.5 06/24/2006 03:50:00 7.3 1 10.7 4.6 6.8 1.1 9.5 3.8 6.9 1.1 9.5 4.2 18 8 15 165 8 0.1 8.3 7.5 06/24/2006 04:00:00 8.3 1.1 11.8 5.7 7.3 1.3 11.5 3.8 8 1.2 11.8 5.3 13 8 31 165 8 0.1 8.3 7.5 06/24/2006 04:10:00 9.1 1.1 12.2 6.5 8.5 1.3 11.5 6.1 8.5 1.1 11.5 5.7 16 9 24 165 8.1 0 8.3 8 06/24/2006 04:20:00 9.7 1.1 12.2 6.1 9 1.5 12.2 4.6 9.1 1.3 12.2 5.7 17 7 23 165 8.1 0 8.3 8 06/24/2006 04:30:00 9 1.1 12.2 5.7 8.3 1.3 11.8 4.6 8.6 1.2 11.8 6.1 17 7 18 165 8 0 8.3 8 06/24/2006 04:40:00 9.2 1.3 11.8 6.1 8.7 1.5 11.8 4.9 8.7 1.4 12.6 5.7 19 9 11 165 8 0 8.3 8 06/24/2006 04:50:00 8.7 1.3 11.5 4.9 8.3 1.4 11.5 4.2 8.3 1.3 11.8 4.9 22 9 22 165 8 0 8.3 8 06/24/2006 05:00:00 8.6 1.4 11.8 5.3 8.4 1.5 11.8 5.3 8.2 1.3 12.2 4.9 26 8 31 165 8 0 8.3 7.8 06/24/2006 05:10:00 7.8 1.3 10.7 4.9 7.7 1.4 10.7 4.6 7.5 1.3 11.1 4.6 27 10 35 165 8 0 8.3 8 06/24/2006 05:20:00 7.2 1 9.9 4.6 7.1 1 9.5 4.6 6.9 1.2 9.5 3.8 31 10 33 165 8 0 8.3 8 06/24/2006 05:30:00 6.9 1.8 11.5 2.6 6.5 1.5 11.1 3 6.5 1.7 11.1 3 24 14 1 165 8.2 0 8.3 8 06/24/2006 05:40:00 7.9 1.5 13 4.6 7.4 1.5 11.8 4.2 7.4 1.5 12.2 4.2 18 11 10 165 8.2 0 8.3 8 06/24/2006 05:50:00 6.3 1.4 9.9 3.8 6.2 1.3 9.9 3 6.1 1.3 9.5 3.4 29 11 25 165 8.2 0 8.5 8 06/24/2006 06:00:00 6.7 1.1 9.5 3.4 6.6 1.1 9.5 3 6.5 1 9.1 4.2 34 9 43 165 8.2 0 8.5 8 06/24/2006 06:10:00 7.6 1.2 9.9 4.6 7.5 1.2 9.9 4.6 7.3 1.3 11.1 4.6 36 8 34 165 8.3 0 8.5 8.3 06/24/2006 06:20:00 7.2 1.1 9.5 4.2 7.1 1.2 9.5 4.2 6.9 1 9.5 4.2 35 9 39 165 8.3 0 8.5 7.8 06/24/2006 06:30:00 7.4 1.2 10.3 3.8 7.2 1.3 10.3 3.8 7 1.2 9.9 3.4 26 9 29 165 8.4 0 8.5 7.8 06/24/2006 06:40:00 8 1.3 11.1 4.9 7.9 1.3 10.7 4.6 8 1.4 11.5 4.2 27 10 26 165 8.3 0 8.5 7.8 06/24/2006 06:50:00 9.3 1.4 12.2 5.7 9.1 1.5 12.2 5.3 8.8 1.4 12.2 6.1 27 8 26 165 8.3 0 8.5 7.8 06/24/2006 07:00:00 8.4 1.3 11.8 5.3 8.3 1.4 11.8 4.9 8 1.3 11.5 4.9 27 9 47 165 8.3 0 8.5 7.8 06/24/2006 07:10:00 7.9 1.1 10.7 5.3 7.7 1.1 10.3 4.9 7.5 1.1 10.7 4.9 28 11 29 165 8.2 0 8.3 7.8 06/24/2006 07:20:00 9.4 1.2 12.6 6.5 9.1 1.3 12.6 6.1 8.9 1.2 12.2 5.7 23 8 26 165 8.3 0 8.5 7.8 06/24/2006 07:30:00 9.1 1.3 12.6 6.1 8.7 1.4 12.6 5.3 8.6 1.4 12.6 5.3 20 8 23 165 8.2 0 8.3 7.5 06/24/2006 07:40:00 7.8 1.4 11.5 4.6 7.5 1.5 11.1 3.4 7.6 1.4 11.5 4.6 21 10 19 165 8.1 0 8.3 7.8 06/24/2006 07:50:00 8 1.4 11.5 4.6 7.8 1.5 11.5 4.2 7.4 1.3 11.1 3.8 28 10 26 165 8.2 0 8.3 7.8 06/24/2006 08:00:00 7.5 1.3 11.8 4.2 7.3 1.3 11.5 4.6 7.2 1.3 10.7 4.2 31 12 26 165 8.2 0 8.5 7.8 06/24/2006 08:10:00 8.6 1.4 11.8 5.7 8.2 1.5 11.5 4.6 8.2 1.4 11.8 4.9 20 10 26 165 8.3 0 8.5 7.8 06/24/2006 08:20:00 9.6 1.3 13 6.5 9.4 1.4 13 5.7 9.3 1.5 12.6 5.3 24 8 21 165 8.3 0 8.5 7.8 06/24/2006 08:30:00 9.5 1.3 12.6 5.7 9.2 1.3 12.6 5.3 9.2 1.4 12.6 4.9 24 8 28 165 8.2 0 8.5 7.8 06/24/2006 08:40:00 8.5 1.2 11.5 5.7 8.3 1.3 11.5 5.3 8.1 1.2 10.7 5.3 25 9 25 165 8.3 0 8.5 8.3 06/24/2006 08:50:00 8.3 1.2 11.8 5.7 8.2 1.3 11.8 5.3 8 1.2 11.8 5.3 25 9 32 165 8.2 0 8.3 8 06/24/2006 09:00:00 9 1 11.5 6.1 8.8 1.1 11.1 6.1 8.9 1 11.1 6.5 24 8 23 165 8.2 0 8.3 8 06/24/2006 09:10:00 9.3 1.2 11.8 5.7 9 1.4 11.8 4.6 9 1.3 11.8 5.7 21 8 16 165 8.2 0 8.5 8 06/24/2006 09:20:00 8.8 1.3 11.8 5.3 8.4 1.4 11.5 4.6 8.6 1.3 12.6 5.7 20 8 15 165 8.3 0 8.5 8.3 06/24/2006 09:30:00 8.3 1.2 11.5 4.9 7.9 1.3 11.5 4.6 8 1.1 11.1 4.9 21 8 26 165 8.3 0 8.5 8.3 06/24/2006 09:40:00 9.3 1 11.5 6.5 8.9 1.1 11.8 6.1 8.9 1.2 11.8 6.1 21 7 16 165 8.3 0 8.5 8.3 06/24/2006 09:50:00 9 0.9 11.5 6.5 8.6 1.1 11.5 5.3 8.6 1 11.5 6.1 20 7 42 165 8.3 0 8.5 8.3 06/24/2006 10:00:00 8.3 1 11.1 6.1 7.9 1 11.1 5.3 8 1 11.1 5.7 22 9 23 165 8.3 0 8.5 8.3 06/24/2006 10:10:00 8.6 1.3 11.8 5.7 8.2 1.5 11.5 3.8 8.3 1.4 11.8 5.7 20 9 19 165 8.5 0 8.5 8.3 06/24/2006 10:20:00 9.5 1.3 13 4.9 9.1 1.5 12.2 5.3 9.1 1.3 12.6 6.1 20 9 25 165 8.5 0 8.5 8.3 06/24/2006 10:30:00 8.8 1.3 12.2 5.7 8.3 1.4 11.8 5.3 8.6 1.2 11.8 5.7 18 9 23 165 8.5 0 8.5 8.5 06/24/2006 10:40:00 9.5 1.1 12.2 6.1 8.9 1.3 11.8 4.2 9.3 1.1 12.2 6.5 18 8 21 165 8.5 0 8.5 8.5 06/24/2006 10:50:00 9.1 1 11.5 6.8 8.5 1.2 11.5 4.9 8.5 1 11.1 5.7 19 9 26 165 8.5 0 8.8 8.3 06/24/2006 11:00:00 9.8 1.5 13 6.1 9.4 1.7 12.6 4.2 9.3 1.5 13 5.3 19 8 26 165 8.7 0 9 8.3 06/24/2006 11:10:00 10 1.2 13 7.2 9.7 1.3 13 5.7 9.7 1.4 13 6.1 21 9 23 165 8.7 0 8.8 8.3 06/24/2006 11:20:00 9.3 1.2 12.2 6.1 9 1.3 11.5 5.7 9 1.3 12.2 5.3 22 9 50 165 8.5 0 8.8 8.3 06/24/2006 11:30:00 9.5 1.2 12.2 6.1 9 1.3 12.2 5.3 9.1 1.3 12.2 5.7 18 8 18 165 8.5 0 8.8 8.3 06/24/2006 11:40:00 9.7 1.1 12.6 6.8 9 1.3 12.2 5.3 9.4 1.3 12.6 5.7 17 8 11 165 8.7 0 9 8.3 06/24/2006 11:50:00 9.2 1.1 11.8 6.5 8.7 1.2 11.8 5.7 8.7 1.2 12.2 6.1 20 8 25 165 8.9 0 9 8.5 06/24/2006 12:00:00 9.8 1.3 13 6.5 9.4 1.5 12.6 5.3 9.4 1.3 12.6 6.1 19 8 14 165 8.9 0 9 8.5 06/24/2006 12:10:00 10 1.2 13.7 6.8 9.6 1.3 13 6.1 9.5 1.2 13 6.5 22 8 20 165 8.9 0 9 8.5 06/24/2006 12:20:00 10.6 1.3 13.3 7.2 10.3 1.4 13.3 6.5 10.2 1.3 13.3 6.5 21 7 32 165 8.9 0 9 8.5 06/24/2006 12:30:00 10.8 1.3 14.1 7.6 10.3 1.5 13.7 6.8 10.4 1.3 14.1 7.2 20 9 26 165 8.7 0.1 9 8.3 06/24/2006 12:40:00 10.3 1.7 14.5 6.5 9.9 1.7 14.1 6.5 9.9 1.6 13.3 6.1 21 8 15 165 8.6 0 8.8 8.3 06/24/2006 12:50:00 10.7 1.3 13.3 7.2 10.2 1.4 13.3 6.1 10.2 1.4 13.7 6.8 20 8 13 165 8.5 0 8.8 8.3 06/24/2006 13:00:00 11.1 1.3 14.9 7.6 10.6 1.5 14.9 6.8 10.7 1.5 14.5 6.8 19 7 25 165 8.5 0 8.8 8.3 06/24/2006 13:10:00 10.4 1.7 13.7 6.1 9.9 1.7 13.7 4.9 10 1.7 13.7 5.7 18 7 24 165 8.5 0 8.8 8.3 06/24/2006 13:20:00 10.5 1.5 14.5 6.8 9.8 1.7 14.5 5.7 9.9 1.5 14.1 6.5 18 8 32 165 8.5 0 8.8 8.5 06/24/2006 13:30:00 10.7 1.5 14.5 7.2 10.3 1.6 14.9 6.5 10.2 1.6 14.5 6.8 20 8 28 165 8.5 0 8.8 8.5 06/24/2006 13:40:00 10 1.4 13.7 6.8 9.6 1.5 13.7 6.1 9.6 1.3 14.1 6.8 21 8 28 165 8.5 0 8.8 8.5 06/24/2006 13:50:00 10.6 1.4 14.1 6.5 10.2 1.5 13.7 6.1 10.2 1.3 12.6 5.7 22 9 17 165 8.5 0 8.8 8.5 06/24/2006 14:00:00 10.8 1.5 13.7 7.2 10.2 1.7 13.7 6.5 10.4 1.4 13.3 6.8 18 9 30 165 8.6 0 8.8 8.5 06/24/2006 14:10:00 9.7 1.4 13 6.1 9 1.5 13 5.7 9.3 1.4 12.6 6.1 16 8 29 165 8.7 0 8.8 8.5 06/24/2006 14:20:00 10.7 1.1 13.7 6.1 10.3 1.3 13.7 6.5 10.4 1.3 14.1 6.5 19 8 21 165 8.7 0 8.8 8.5 06/24/2006 14:30:00 10.3 1.8 14.5 5.3 9.1 1.9 14.1 4.6 9.8 1.9 14.1 5.7 14 8 10 165 8.9 0 9 8.8 06/24/2006 14:40:00 10.5 1.4 13.3 6.1 9.4 1.7 13.3 4.2 10.1 1.4 13.7 6.1 13 8 12 165 8.8 0 9 8.8 06/24/2006 14:50:00 9 1.1 11.5 6.5 8.2 1.4 11.5 4.6 8.8 1.2 11.8 5.7 14 9 11 165 8.9 0 9 8.8 06/24/2006 15:00:00 10.1 1.2 13.3 7.2 8.7 1.5 11.8 5.3 10.1 1.2 13.7 6.8 12 8 2 165 8.9 0 9 8.8 06/24/2006 15:10:00 10.2 1.2 13.3 6.5 8.9 1.5 13 4.6 9.9 1.3 13 6.5 12 8 15 165 8.9 0 9 8.8 06/24/2006 15:20:00 9.7 1.2 12.6 6.8 8.3 1.4 11.8 4.9 9.4 1.1 12.2 6.1 10 9 15 165 8.9 0 9 8.8 06/24/2006 15:30:00 10.1 1.3 13 6.5 9.1 1.7 13.3 5.3 9.7 1.3 13.3 5.7 13 9 25 165 8.9 0 9 8.5 06/24/2006 15:40:00 10.3 1.3 13.3 7.2 9.3 1.5 12.6 5.3 9.8 1.4 13.3 6.5 15 8 11 165 8.9 0 9 8.5 06/24/2006 15:50:00 10.4 1.5 14.1 5.7 9.4 1.7 13.3 5.7 9.8 1.5 13.7 6.5 14 7 18 165 8.9 0 9 8.5 06/24/2006 16:00:00 10.2 1.1 12.6 7.2 9.4 1.4 12.2 5.7 9.9 1.2 12.2 6.5 15 7 16 165 8.9 0 9 8.5 06/24/2006 16:10:00 9.9 1.2 12.6 6.5 9.2 1.4 12.2 5.7 9.5 1.3 12.6 6.1 16 8 19 165 8.8 0 9 8.5 06/24/2006 16:20:00 9.8 1.3 13 6.1 8.3 1.6 12.2 4.9 9.5 1.3 13 6.1 11 8 5 165 8.7 0 8.8 8.5 06/24/2006 16:30:00 10 1.1 13 6.5 8.8 1.2 12.2 6.1 9.6 1.1 12.2 6.5 13 7 14 165 8.7 0 8.8 8.5 06/24/2006 16:40:00 9.8 1.3 13.3 6.8 8.3 1.6 11.5 4.6 9.6 1.3 12.6 6.5 10 7 7 165 8.8 0 9 8.5 06/24/2006 16:50:00 10 1.2 13 6.8 8.6 1.5 13 5.3 9.5 1.2 13 6.5 8 9 20 165 8.8 0 9 8.5 06/24/2006 17:00:00 9 1.2 12.6 6.1 8 1.5 12.2 4.6 8.8 1.2 13 6.1 13 8 31 165 8.9 0 9 8.5 06/24/2006 17:10:00 9.9 1.1 12.6 7.2 8.7 1.6 12.6 4.9 9.6 1.1 13 7.2 12 7 25 165 8.9 0 9 8.5 06/24/2006 17:20:00 9.4 1.3 13 6.1 8.1 1.5 12.6 4.6 9.1 1.3 13 5.7 10 9 16 165 8.9 0 9 8.5 06/24/2006 17:30:00 9.3 1.2 13.3 6.5 8.7 1.5 13 5.7 8.9 1.2 13 6.1 17 9 34 165 8.8 0 9 8.5 06/24/2006 17:40:00 10.3 1.3 14.1 7.2 9.7 1.6 13.7 5.7 9.8 1.5 14.1 6.5 18 9 16 165 8.7 0 8.8 8.3 06/24/2006 17:50:00 9.5 1.1 12.6 6.8 8.1 1.5 11.8 4.6 9.1 1.2 13 6.5 11 7 12 165 8.8 0 9 8.8 06/24/2006 18:00:00 9.1 1.2 13 6.8 7.8 1.3 12.2 4.9 8.7 1.2 12.2 6.5 10 8 11 165 8.8 0 9 8.8 06/24/2006 18:10:00 10.2 1.2 13.3 6.8 8.4 1.5 11.8 4.6 9.8 1.2 13.3 6.8 10 7 11 165 8.9 0 9 8.8 06/24/2006 18:20:00 10.5 1.2 13.7 7.6 8.8 1.5 12.2 5.3 10.1 1.2 14.1 6.5 11 7 11 165 8.9 0 9 8.8 06/24/2006 18:30:00 9.6 1.1 13.3 7.2 8.5 1.4 12.2 5.3 9.2 1.1 12.2 6.8 13 7 16 165 8.8 0 9 8.8 06/24/2006 18:40:00 9.5 0.9 11.8 6.8 8.6 1.3 11.5 4.9 9.1 1 12.2 6.1 14 7 22 165 8.8 0 9 8.8 06/24/2006 18:50:00 9.8 1.1 12.2 7.2 8.3 1.7 12.2 4.9 9.6 1.1 11.8 6.5 11 8 21 165 8.8 0 9 8.8 06/24/2006 19:00:00 8.6 1 11.1 6.1 6.6 1.4 10.3 3.8 8.4 1 11.5 5.7 7 8 19 165 8.9 0 9 8.8 06/24/2006 19:10:00 9.8 1.5 13.7 6.1 8.7 1.8 13.3 4.9 9.5 1.6 13.7 6.1 13 7 26 165 8.9 0 9 8.8 06/24/2006 19:20:00 9.9 1.3 13.3 6.8 8.4 1.6 12.2 3.8 9.7 1.3 13.3 6.5 11 7 9 165 8.9 0 9 8.8 06/24/2006 19:30:00 10.1 1.3 14.1 6.5 8.9 1.7 14.1 4.9 9.7 1.3 13 6.5 13 8 25 165 8.9 0 9 8.8 06/24/2006 19:40:00 9.4 1.1 12.6 6.5 8.2 1.3 11.8 5.3 9.2 1.1 12.2 6.5 13 8 8 165 8.9 0 9 8.8 06/24/2006 19:50:00 9.6 1.2 14.1 6.8 8.8 1.6 14.1 4.6 9.2 1.3 14.1 6.1 15 9 23 165 8.9 0 9 8.8 06/24/2006 20:00:00 9.4 1.3 13.3 6.5 8.6 1.5 13 5.3 9.2 1.3 13 6.5 15 9 7 165 8.9 0 9 8.5 06/24/2006 20:10:00 10.5 1.3 14.5 7.2 9.2 1.6 13 4.9 10.1 1.5 13.7 6.8 12 9 5 165 9 0 9 8.5 06/24/2006 20:20:00 10.9 1.2 14.1 7.6 9.4 1.3 13.3 6.1 10.6 1.2 13.3 7.2 12 7 15 165 8.9 0 9 8.5 06/24/2006 20:30:00 10 1.1 13.3 6.8 8.4 1.4 13 5.7 9.7 1.1 13.3 6.8 11 7 10 165 8.9 0 9 8.5 06/24/2006 20:40:00 10.1 1 12.6 7.6 8.8 1.3 11.8 5.3 9.8 1.1 13 6.8 11 6 7 165 8.9 0 9 8.5 06/24/2006 20:50:00 9.9 1 12.6 7.2 8.1 1.3 11.5 4.2 9.8 1 12.2 7.2 9 6 12 165 8.8 0 9 8.5 06/24/2006 21:00:00 9.8 1.2 13.3 7.2 7.9 1.3 11.5 4.9 9.6 1.2 13.3 6.8 8 7 6 165 8.7 0 9 8.5 06/24/2006 21:10:00 10.3 1 13 7.6 8.3 1.5 12.6 4.9 10.1 1.1 13 7.6 10 7 10 165 8.7 0 8.8 8.3 06/24/2006 21:20:00 10.1 1.3 13.7 6.8 7.8 1.8 12.6 4.6 9.9 1.4 13.7 6.8 7 9 7 165 8.7 0 8.8 8.5 06/24/2006 21:30:00 9.4 1.3 12.2 5.7 7.2 1.7 11.8 3.8 9.1 1.2 12.2 5.7 7 8 2 165 8.8 0 9 8.5 06/24/2006 21:40:00 9.5 1.3 13 6.1 7.5 1.9 13 4.6 9.4 1.5 14.5 6.5 9 8 22 165 8.9 0 9 8.5 06/24/2006 21:50:00 8.8 1 11.8 5.7 7 1.5 11.1 3.8 8.7 1 11.5 6.1 6 9 10 165 8.9 0 9 8.5 06/24/2006 22:00:00 8.8 1.3 12.6 5.3 6.8 1.7 12.2 3.4 8.7 1.3 13.7 5.7 7 9 10 165 9 0 9 8.5 06/24/2006 22:10:00 10.3 1.3 13.7 4.9 7.6 1.8 13 3.8 10.3 1.3 14.5 5.7 6 9 15 165 9 0.1 9.3 8.5 06/24/2006 22:20:00 10.4 1.6 14.5 6.8 8 1.7 13.3 4.9 10.2 1.7 14.9 6.5 7 9 8 165 9.1 0 9.3 8.8 06/24/2006 22:30:00 9.8 1.3 13.7 6.5 7.3 1.7 12.2 4.2 9.5 1.3 13 6.8 4 9 7 165 9.1 0 9.3 9 06/24/2006 22:40:00 11.8 1.7 16.8 7.2 9.1 2.3 16.4 4.9 11.6 1.7 17.6 6.8 7 8 23 165 9.1 0 9.3 9 06/24/2006 22:50:00 10.4 1.5 14.5 5.7 7.7 1.7 13.7 4.6 10.2 1.6 14.9 5.7 359 8 3 165 9.1 0 9.3 9 06/24/2006 23:00:00 11 1.7 17.2 7.6 8.2 1.9 14.9 4.9 10.8 1.6 16.1 8 358 8 9 165 9.1 0 9.3 9 06/24/2006 23:10:00 10.5 1.4 14.5 6.8 7.8 1.7 12.6 4.2 10.3 1.4 14.1 6.5 1 9 3 165 9.1 0 9.3 9 06/24/2006 23:20:00 10.1 1.5 13.7 6.5 7.6 1.7 13 4.2 9.8 1.5 13.3 5.7 360 8 354 165 9.2 0 9.3 9 06/24/2006 23:30:00 9.5 1.5 14.1 6.5 7.4 1.8 13.3 4.2 9.4 1.6 14.5 6.1 3 9 15 165 9.2 0.1 9.3 9 06/24/2006 23:40:00 9.8 1.2 13 7.2 7.3 1.3 11.1 4.6 9.6 1.4 13.3 6.5 2 8 3 165 9 0 9 8.8 06/24/2006 23:50:00 10.5 1.4 14.5 6.8 8.9 2 14.5 4.9 10.1 1.6 14.5 6.5 355 9 360 165 8.9 0 9 8.8 06/25/2006 00:00:00 9.9 1.7 14.1 5.7 8.4 2 14.9 4.2 9.3 1.7 13.3 4.9 352 8 346 165 8.9 0 9 8.8 06/25/2006 00:10:00 10.2 1.5 14.1 6.5 8.5 1.7 13.3 4.6 9.6 1.6 13.7 5.7 356 11 17 165 9 0 9 8.8 06/25/2006 00:20:00 9.2 1.2 11.8 6.5 7.1 1.5 11.8 3.8 8.9 1.1 11.8 6.5 359 8 10 165 9 0 9 8.8 06/25/2006 00:30:00 10.9 1.7 14.1 6.1 8.5 2.1 14.1 4.9 10.5 1.8 14.5 6.5 357 8 358 165 9 0 9 8.8 06/25/2006 00:40:00 10.3 1.4 13.7 6.8 8.3 1.5 13.7 4.2 9.9 1.4 13.3 6.1 355 7 358 165 9 0 9 8.5 06/25/2006 00:50:00 10.9 1.2 15.6 7.6 9.1 1.6 13.7 6.1 10.4 1.4 14.9 7.2 353 8 357 165 9 0 9 8.5 06/25/2006 01:00:00 11.9 1.4 16.1 8 10.2 1.6 14.5 6.8 11 1.5 15.3 6.1 352 8 349 165 9 0.1 9 8.5 06/25/2006 01:10:00 15.1 1.8 19.5 10.3 11.6 1.8 17.2 7.6 14.4 2.1 18.7 9.9 356 8 358 165 9 0.1 9 8.5 06/25/2006 01:20:00 15.1 1.7 19.9 10.3 12.8 2.4 18.7 7.2 14.8 2 21 9.1 354 8 351 165 9 0.1 9.3 8.5 06/25/2006 01:30:00 16 1.7 21.4 11.1 13.1 2.1 19.1 8 15.4 1.9 21 9.9 354 8 356 165 9 0.1 9.3 8.5 06/25/2006 01:40:00 15.5 2.5 21 8.4 12.3 2.5 19.9 6.8 14.8 2.5 20.2 8 356 8 7 165 9.1 0.1 9.3 8.8 06/25/2006 01:50:00 15.4 1.6 19.1 10.3 11.8 2.3 19.1 8 15.1 1.7 20.2 10.3 357 8 2 165 9 0.1 9.3 8.5 06/25/2006 02:00:00 15.6 2.1 21 10.7 11.8 2.1 17.9 7.2 15.2 2.3 21 10.3 359 8 6 165 9 0 9.3 8.5 06/25/2006 02:10:00 15.3 2.4 21.8 10.7 12.2 2.3 18.7 7.2 14.9 2.6 21.8 10.7 359 9 358 165 8.9 0 9 8.5 06/25/2006 02:20:00 17 2.3 24 9.5 13.8 2.9 24.8 6.8 16.6 2.4 23.3 9.1 358 10 344 165 8.9 0 9 8.3 06/25/2006 02:30:00 17.8 2.2 24.8 12.6 14.2 3.2 24 8.8 17.3 2.3 23.7 11.8 357 8 2 165 8.8 0 9 8.3 06/25/2006 02:40:00 17.8 2.4 24.4 11.5 15.1 3.1 24.4 10.3 16.9 2.6 24.8 10.3 353 12 2 165 8.9 0 9 8.3 06/25/2006 02:50:00 15.9 2 20.6 10.7 13.1 2.6 20.2 8.4 15.3 2.2 21 9.9 358 9 356 165 9 0 9 8.3 06/25/2006 03:00:00 13 1.7 18.3 8.8 10.7 2.1 16.1 6.5 12.5 1.8 18.3 6.1 356 9 10 165 8.9 0 9 8.8 06/25/2006 03:10:00 13.3 1.7 19.5 9.1 9.9 2.2 19.1 5.3 13 1.7 18.3 8.4 359 7 341 165 8.9 0 9 8.8 06/25/2006 03:20:00 10.9 1.5 14.9 8 8.3 1.5 14.5 5.3 10.7 1.6 16.1 6.5 5 8 356 165 8.9 0 9 8.8 06/25/2006 03:30:00 11.2 1.5 14.1 7.2 9.6 2 14.1 4.6 10.8 1.3 14.5 7.6 11 8 11 165 8.9 0 9 8.8 06/25/2006 03:40:00 10.8 1.5 13.3 5.7 10.4 1.6 13.3 5.7 10.4 1.5 13.7 5.7 23 8 17 165 8.7 0 9 8.5 06/25/2006 03:50:00 8 1.3 11.1 4.9 7.7 1.3 11.1 4.6 7.7 1.2 11.5 5.3 28 9 34 165 8.5 0 8.8 8.5 06/25/2006 04:00:00 8 1.5 13 4.6 7.6 1.6 12.6 3 7.8 1.5 12.6 4.9 22 9 23 165 8.3 0 8.5 8.3 06/25/2006 04:10:00 7.1 1.1 9.5 4.6 6.7 1.2 9.5 4.2 6.8 1 9.5 4.6 21 9 18 165 8.2 0 8.3 8.3 06/25/2006 04:20:00 7.6 1 10.3 5.3 6.5 1.3 9.9 3.4 7.3 1 10.7 5.3 13 8 26 165 8.2 0 8.3 8 06/25/2006 04:30:00 7.1 0.8 9.9 4.9 5.3 0.9 8 2.6 7 0.9 9.5 4.6 6 7 17 165 8.2 0 8.3 8 06/25/2006 04:40:00 8.9 1.1 11.5 5.7 7.2 1.7 11.1 4.2 8.5 1.3 11.5 4.9 8 7 13 165 8.1 0 8.3 8 06/25/2006 04:50:00 9.4 0.8 11.1 6.1 8.6 1.1 10.7 5.3 9 1 11.1 6.5 16 6 15 165 8 0 8.3 7.8 06/25/2006 05:00:00 9.5 0.9 11.8 7.2 9.1 1.1 11.5 5.3 9.1 1 11.5 5.7 20 6 18 165 8 0 8 7.8 06/25/2006 05:10:00 8.7 1 11.1 6.1 7.9 1.3 10.7 4.2 8.5 1 10.7 5.3 16 8 19 165 8 0.1 8 7.5 06/25/2006 05:20:00 7.5 0.9 9.9 4.9 6.2 1.1 9.1 3.8 7.4 0.9 9.9 4.9 11 7 20 165 7.9 0 8 7.3 06/25/2006 05:30:00 8.1 0.8 10.3 5.7 5.8 1 9.1 3.4 7.7 0.9 9.5 4.9 4 7 7 165 7.8 0 8 7.3 06/25/2006 05:40:00 7.7 0.8 9.5 5.7 5.4 1 8.4 3.4 7.7 0.9 10.3 4.9 1 7 349 165 7.8 0 8 7.3 06/25/2006 05:50:00 7.9 0.9 10.3 5.3 5.7 1.2 9.1 3 7.7 0.9 10.3 5.3 3 8 359 165 8 0.1 8 7.5 06/25/2006 06:00:00 8.2 1 11.1 6.1 6.3 1.5 9.1 2.6 7.9 1 11.1 5.7 355 6 355 165 8 0 8.3 7.5 06/25/2006 06:10:00 7.3 0.9 9.5 4.9 6.4 1.3 9.1 3.4 6.9 1 9.1 4.6 352 8 353 165 8.1 0 8.3 7.8 06/25/2006 06:20:00 7.6 1.2 9.9 4.9 5.4 1.3 9.1 2.6 7.3 1.3 10.7 4.6 0 8 5 165 8.3 0 8.5 7.8 06/25/2006 06:30:00 8.3 1.3 11.5 4.9 6 1.2 9.5 3.4 8.1 1.3 11.8 5.3 2 7 359 165 8.3 0 8.5 7.8 06/25/2006 06:40:00 9.2 1.1 13 6.1 6.9 1.4 11.1 3.8 8.9 1.3 12.2 5.7 358 7 357 165 8.3 0 8.5 7.8 06/25/2006 06:50:00 7.3 1 10.3 5.3 5.5 1.5 9.9 3 7.3 1 10.3 4.9 358 7 355 165 8.2 0 8.5 7.5 06/25/2006 07:00:00 8.3 1.1 10.7 5.7 6.5 1.5 9.9 3.4 8 1 10.3 6.1 356 7 358 165 8.2 0 8.3 7.8 06/25/2006 07:10:00 9.1 1 11.8 5.3 6.9 1.2 10.7 4.2 8.9 1 11.8 6.5 1 8 354 165 8.3 0 8.5 7.5 06/25/2006 07:20:00 9 1.3 12.2 5.7 7.6 1.5 11.5 3.4 8.7 1.3 12.2 5.7 11 9 358 165 8.1 0 8.3 7.8 06/25/2006 07:30:00 9 1.2 12.2 5.3 7.4 1.4 11.5 4.2 8.7 1.3 11.5 5.7 10 8 12 165 8.1 0 8.3 8 06/25/2006 07:40:00 10.8 1.1 13.3 7.6 8.1 1.5 12.6 4.9 10.5 1.2 13.3 6.8 6 7 9 165 8.2 0 8.3 8 06/25/2006 07:50:00 11.5 1.4 14.5 8 8.5 1.5 13 4.6 11.4 1.5 14.9 7.6 5 7 359 165 8.3 0 8.5 8.3 06/25/2006 08:00:00 10 1.2 13.7 6.8 8.4 1.5 13 4.9 9.8 1.1 13.7 7.2 11 9 11 165 8.4 0 8.8 8.3 06/25/2006 08:10:00 10.1 1.5 13 5.3 9.5 1.5 13 4.9 9.7 1.4 13.7 5.7 23 11 28 165 8.3 0 8.5 8.3 06/25/2006 08:20:00 10.3 1.3 13.7 6.5 8.7 1.5 12.2 5.3 10.1 1.3 13.3 6.1 12 7 2 165 8.2 0 8.5 8.3 06/25/2006 08:30:00 9.2 1 11.8 6.8 7.8 1.2 11.1 4.9 8.8 1 11.8 6.5 11 6 14 165 8.2 0 8.5 8.3 06/25/2006 08:40:00 10 1 13 6.8 8.2 1.3 11.5 4.9 9.9 0.9 12.6 7.6 10 6 3 165 8.4 0 8.5 8.3 06/25/2006 08:50:00 10.3 1.1 13.7 8 8.2 1.4 12.2 4.9 10.1 1.1 13.3 7.6 8 6 2 165 8.5 0 8.8 8.5 06/25/2006 09:00:00 9.6 1.1 12.2 6.8 7.3 1.5 10.7 3.4 9.4 1.2 12.6 6.5 8 6 9 165 8.5 0 9 8.5 06/25/2006 09:10:00 9.9 1.3 13.7 7.2 8.7 1.8 13.3 5.3 9.7 1.5 13.7 6.5 13 8 23 165 8.7 0 9 8.5 06/25/2006 09:20:00 10.4 1 13 7.2 9.7 1.3 13 5.3 10.1 1.2 13.3 7.2 17 6 18 165 8.7 0 8.8 8.5 06/25/2006 09:30:00 10.7 1.1 13.3 7.2 10.1 1.3 13.3 6.1 10.3 1.3 13.3 6.5 18 7 16 165 8.8 0 9 8.8 06/25/2006 09:40:00 8.5 1.3 11.5 5.7 8.1 1.3 11.1 4.9 8.3 1.2 11.5 5.7 21 9 23 165 8.9 0.1 9.3 8.8 06/25/2006 09:50:00 9.2 1.2 11.8 5.7 8.7 1.4 11.8 5.3 9 1.2 11.8 6.1 19 8 25 165 9.2 0 9.3 8.8 06/25/2006 10:00:00 8.9 1 11.5 6.1 8.3 1.2 11.1 4.9 8.7 1 11.1 5.7 18 8 19 165 9.2 0.1 9.6 8.8 06/25/2006 10:10:00 8.2 1.2 10.7 5.3 8 1.3 10.3 4.6 8 1.3 10.7 4.6 25 9 25 165 9 0 9.3 8.8 06/25/2006 10:20:00 9.3 1.4 11.8 4.9 8.9 1.6 11.8 4.9 8.9 1.5 12.2 5.3 21 8 21 165 9.3 0 9.6 9 06/25/2006 10:30:00 9.5 1.2 12.2 6.1 8.4 1.7 11.5 4.2 9.3 1.2 12.2 6.1 14 8 9 165 9.5 0 9.6 9.3 06/25/2006 10:40:00 8.5 1.2 11.1 4.9 7.6 1.5 11.1 4.2 8.4 1.2 11.1 4.6 15 10 10 165 9.4 0 9.6 9 06/25/2006 10:50:00 10 1.5 13.3 5.7 9.3 1.6 13 5.7 9.8 1.5 13.3 6.1 18 8 1 165 9.4 0 9.6 8.8 06/25/2006 11:00:00 10.7 1.2 13.3 7.2 10.3 1.4 12.6 5.7 10.4 1.2 13.3 6.8 20 7 18 165 9.4 0 9.6 8.8 06/25/2006 11:10:00 10 1.2 12.2 6.5 9.3 1.7 12.6 4.2 9.8 1.3 13.3 6.8 17 7 23 165 9.3 0 9.6 8.8 06/25/2006 11:20:00 8.9 1 11.1 6.1 8 1.4 11.1 4.6 8.7 1 11.1 5.7 15 8 9 165 9.2 0.2 9.6 8.5 06/25/2006 11:30:00 8.3 1.1 11.1 5.7 7.7 1.3 11.1 4.2 8.3 1.1 11.8 5.7 18 8 21 165 9.2 0.1 9.6 8.5 06/25/2006 11:40:00 8.2 1 10.7 5.3 7.7 1.3 10.7 3.4 8 1 10.3 5.7 20 8 7 165 9.4 0.2 9.6 8.8 06/25/2006 11:50:00 8.3 1 10.3 4.9 8 1.1 10.3 4.6 8.1 1 9.9 4.9 21 8 31 165 9.3 0.1 9.6 8.8 06/25/2006 12:00:00 8.9 1.2 12.2 5.3 8.3 1.5 11.8 4.6 8.7 1.2 11.8 5.7 19 9 15 165 9.4 0.2 9.6 8.8 06/25/2006 12:10:00 9.3 1.1 12.2 5.7 8.5 1.5 12.2 4.6 9.1 1.1 11.8 6.1 15 8 18 165 9.6 0.1 9.6 9 06/25/2006 12:20:00 8.7 1 11.5 5.7 8 1.1 11.5 4.9 8.5 1 10.7 6.1 17 7 23 165 9.2 0.2 9.6 8.5 06/25/2006 12:30:00 8.7 1.3 11.8 5.3 8.3 1.5 11.5 3.4 8.5 1.4 11.8 4.6 19 9 19 165 9 0.1 9.3 8.5 06/25/2006 12:40:00 8.2 1 10.3 4.9 7.7 1.1 10.3 4.6 8 1 10.3 5.3 19 8 18 165 8.9 0 9.6 8.8 06/25/2006 12:50:00 8.3 1.2 11.1 5.7 8.1 1.3 11.1 5.3 8 1.2 11.8 4.6 26 9 35 165 8.8 0 9 8.8 06/25/2006 13:00:00 8.3 1.3 11.8 5.3 7.9 1.5 11.8 4.2 8 1.3 12.2 4.6 22 9 20 165 8.7 0 9 8.5 06/25/2006 13:10:00 8.5 1.2 10.7 5.7 8.2 1.4 11.1 3.8 8.3 1.3 11.1 5.3 22 7 24 165 8.6 0 8.8 8.5 06/25/2006 13:20:00 7.3 0.9 9.5 4.6 6.8 1 9.1 4.2 7.2 0.9 9.5 4.9 17 8 19 165 8.7 0 8.8 8.5 06/25/2006 13:30:00 7.3 1 11.1 4.6 6.8 1.1 10.3 3.4 7 1.1 10.3 4.9 19 9 14 165 8.7 0 9 8.5 06/25/2006 13:40:00 8.4 1 11.1 4.6 7.9 1.2 11.1 4.2 8 0.9 11.1 6.1 19 8 18 165 8.8 0 9 8.8 06/25/2006 13:50:00 8.5 1.1 11.1 4.9 8.1 1.3 11.1 4.9 8.2 1.2 10.7 4.9 20 7 18 165 8.8 0 9 8.8 06/25/2006 14:00:00 8.1 1.1 10.3 5.3 7.7 1.3 10.3 4.6 7.8 1.1 10.7 4.6 21 8 28 165 8.9 0 9 8.8 06/25/2006 14:10:00 7.8 1 10.3 5.3 7.4 1.1 9.9 4.9 7.5 1 9.5 5.3 21 8 29 165 8.9 0 9 8.8 06/25/2006 14:20:00 7.5 1 10.7 4.9 7.1 1 10.7 4.6 7.4 0.9 10.3 4.6 22 9 23 165 8.8 0 9 8.5 06/25/2006 14:30:00 7.2 1 9.5 4.9 6.5 1.2 9.5 3.4 7.2 1 9.5 5.3 16 8 25 165 9 0 9 8.5 06/25/2006 14:40:00 7.9 1.1 9.9 4.6 7.2 1.4 9.5 3 7.9 1.1 9.9 5.3 16 8 18 165 9 0 9.3 8.8 06/25/2006 14:50:00 8.3 0.6 9.9 6.1 7.7 0.8 9.1 4.9 8.2 0.9 9.9 5.3 18 5 18 165 9.1 0 9.3 8.8 06/25/2006 15:00:00 7.7 0.8 9.1 5.3 7.1 1 9.1 4.2 7.6 0.9 9.5 5.3 18 6 14 165 9.6 0.1 9.8 9 06/25/2006 15:10:00 7.3 0.9 9.1 5.3 6.8 1.1 8.8 3.4 7.4 0.9 9.1 5.3 19 8 16 165 10.1 0.2 10.9 9.3 06/25/2006 15:20:00 7.1 0.8 9.1 4.2 6.8 1 9.1 4.2 7.1 1 9.5 4.2 25 10 33 165 10.3 0.2 10.9 9.6 06/25/2006 15:30:00 7 0.6 8.8 5.3 6.7 0.7 8.4 4.2 7.2 0.7 8.4 4.9 24 8 29 165 9.8 0.2 10.3 9.6 06/25/2006 15:40:00 6.4 0.7 8.4 3.8 6.2 0.8 8 3.4 6.5 0.8 8 4.2 23 8 14 165 9.8 0.2 10.3 9.6 06/25/2006 15:50:00 6.7 0.6 8.4 4.6 6.5 0.7 8 4.2 6.8 0.8 8.8 4.6 22 6 10 165 10 0.2 10.6 9.6 06/25/2006 16:00:00 6.1 0.8 8 3.8 5.9 0.8 7.6 3.4 6.3 0.8 8.4 4.2 22 8 26 165 10.7 0.3 11.1 9.8 06/25/2006 16:10:00 5.9 0.8 7.6 3.8 5.9 0.8 7.6 3.8 6.1 0.8 8 3.8 27 7 28 165 10.7 0 11.1 10.6 06/25/2006 16:20:00 5.9 0.7 7.6 4.2 5.5 0.9 7.6 3 6.1 0.8 8 3.8 20 8 25 165 10.9 0 11.4 10.6 06/25/2006 16:30:00 5.8 0.7 7.6 3.8 5.6 0.8 7.2 3.8 6 0.7 7.6 4.2 23 7 25 165 10.9 0.2 11.4 10.3 06/25/2006 16:40:00 5.3 0.7 6.8 3 5.1 0.7 6.5 3 5.5 0.7 7.6 3.8 21 9 32 165 11 0 11.4 10.9 06/25/2006 16:50:00 5.3 0.7 6.5 3 4.9 0.8 6.1 3 5.5 0.8 7.2 3.8 17 8 21 165 11.2 0.1 11.4 10.9 06/25/2006 17:00:00 6.1 0.8 7.6 3.4 5.7 0.9 7.2 2.6 6.3 0.8 8.4 3.8 18 8 4 165 11.1 0 11.4 10.6 06/25/2006 17:10:00 6.2 0.9 8.4 3.8 6 0.9 8.4 3.4 6.4 0.9 8.8 4.2 21 10 20 165 10.8 0.1 11.1 10.3 06/25/2006 17:20:00 6 0.7 7.6 4.6 5.6 0.9 7.2 3 6.1 0.7 8 4.2 17 9 16 165 10.6 0.1 11.1 10.3 06/25/2006 17:30:00 5.6 0.6 7.2 4.2 5.5 0.6 7.2 3.4 5.7 0.8 8 3.8 26 8 11 165 10.2 0.1 10.6 9.8 06/25/2006 17:40:00 5.2 0.7 7.2 3.4 5.2 0.7 7.2 3.4 5.5 0.8 7.2 3.4 27 10 9 165 10.5 0.3 11.1 9.8 06/25/2006 17:50:00 5.8 0.7 8 4.2 5.7 0.8 7.6 3 5.9 0.8 8 3.8 22 9 23 165 10.8 0.2 11.1 10.3 06/25/2006 18:00:00 5.9 0.7 7.6 3.8 5.6 0.8 7.6 3.4 5.9 0.8 7.6 3.4 23 11 15 165 10.7 0.2 11.1 9.8 06/25/2006 18:10:00 5.7 0.7 7.2 3.4 5.5 0.7 7.2 3 5.7 0.8 7.2 3 21 8 18 165 10.9 0 11.1 10.9 06/25/2006 18:20:00 5.7 0.6 7.2 3.4 5.5 0.8 7.2 3 5.7 0.7 7.2 3.8 22 8 28 165 10.4 0.3 10.9 9.8 06/25/2006 18:30:00 5.8 0.7 8 3.8 5.1 0.9 6.8 3 5.9 0.6 7.6 4.2 15 9 5 165 10.4 0.2 10.9 9.6 06/25/2006 18:40:00 5.6 0.6 7.2 3.8 5.2 0.7 6.8 2.6 5.8 0.6 7.6 3.8 17 7 19 165 10.1 0.2 10.9 9.3 06/25/2006 18:50:00 4.4 0.7 5.7 2.3 4 0.8 5.7 1.9 4.7 0.6 6.1 3 16 9 12 165 10.1 0.2 10.6 9.8 06/25/2006 19:00:00 4.3 0.6 5.7 2.6 3.4 0.6 5.3 1.9 4.5 0.7 5.7 2.6 7 9 1 165 10.1 0.1 10.6 9.8 06/25/2006 19:10:00 3.8 0.5 4.9 2.3 3.5 0.6 4.6 1.9 4.2 0.5 5.3 2.6 13 6 6 165 9.6 0.2 10.3 9 06/25/2006 19:20:00 4 0.5 4.9 1.9 3.3 0.7 4.9 1.9 4.3 0.5 5.3 2.6 9 9 21 165 9.6 0.2 10.1 9 06/25/2006 19:30:00 4.2 0.7 6.1 2.6 3.7 0.9 5.7 1.5 4.4 0.6 6.5 3 13 8 16 165 9.6 0.3 10.3 9 06/25/2006 19:40:00 5.4 0.6 6.8 3.4 4.9 0.8 6.8 2.6 5.7 0.6 7.2 3.8 15 7 8 165 10.1 0.1 10.3 9.6 06/25/2006 19:50:00 5.1 0.6 6.5 3 4.7 0.7 6.1 2.6 5.2 0.6 6.8 3.8 17 7 26 165 9.8 0.2 10.3 9.3 06/25/2006 20:00:00 5.1 0.6 6.5 3 4.9 0.7 6.8 3 5.3 0.6 6.5 3.4 20 6 37 165 9.8 0.1 9.8 9.3 06/25/2006 20:10:00 4.6 0.5 6.1 3.4 4.4 0.7 6.1 1.9 4.6 0.6 6.5 3 16 6 20 165 9.4 0.2 9.8 8.8 06/25/2006 20:20:00 4.8 0.5 5.7 2.6 4.2 0.8 6.1 1.9 4.8 0.6 6.1 3.4 13 5 12 165 9.2 0.3 9.6 8.8 06/25/2006 20:30:00 4.9 0.3 6.1 3.4 3.3 0.7 4.9 2.3 4.8 0.4 5.7 3.8 6 5 7 165 9 0 9.3 8.8 06/25/2006 20:40:00 5.2 0.4 6.1 3.8 4.1 0.9 5.7 1.9 5.1 0.5 6.1 3.8 10 6 359 165 8.7 0.2 9.6 8 06/25/2006 20:50:00 5 0.4 6.1 3.4 4.7 0.6 6.1 2.3 4.8 0.5 5.7 3 16 4 18 165 8.2 0.1 8.8 7.5 06/25/2006 21:00:00 5.2 0.4 6.1 3.8 4.6 0.6 5.7 2.3 5.2 0.5 6.5 3.8 14 4 14 165 8 0.1 8.3 7.5 06/25/2006 21:10:00 5 0.4 6.1 3.8 3.5 0.6 5.3 1.9 4.9 0.4 5.7 3.8 8 3 6 165 7.9 0 8.5 7.8 06/25/2006 21:20:00 4.9 0.3 5.7 4.2 3.7 0.7 5.3 2.3 5 0.3 5.7 4.2 11 3 12 165 7.8 0 8 7.8 06/25/2006 21:30:00 4.8 0.3 5.7 3.8 3.2 0.8 4.9 1.5 5.1 0.3 5.7 4.6 8 4 9 165 7.7 0 8.3 7.8 06/25/2006 21:40:00 3.9 0.3 4.9 3.4 2.1 0.4 3.8 1.5 4.3 0.3 5.3 3.8 0 4 9 165 7.6 0.1 8.3 7.5 06/25/2006 21:50:00 5.3 0.3 6.1 4.6 4.5 0.8 5.7 2.6 5.5 0.3 6.1 4.9 12 3 16 165 7.5 0 7.8 7.5 06/25/2006 22:00:00 5.3 0.3 6.1 4.2 4 1 6.1 2.3 5.6 0.4 6.5 4.9 11 5 18 165 7.7 0 7.8 7.5 06/25/2006 22:10:00 5.5 0.3 6.5 4.9 3.5 0.8 5.7 1.9 5.5 0.4 6.5 4.9 8 3 14 165 7.6 0.1 7.8 7.5 06/25/2006 22:20:00 5.6 0.3 6.5 4.9 3.8 0.8 5.7 1.9 5.6 0.4 6.5 4.9 9 3 12 165 7.4 0 7.5 7.3 06/25/2006 22:30:00 6 0.4 6.8 4.9 5.3 1 6.8 3 6.2 0.5 7.2 5.3 15 4 21 165 7.4 0.1 7.8 7.3 06/25/2006 22:40:00 5.1 0.5 6.1 3.8 4.2 0.8 5.7 1.9 4.8 0.7 6.5 3.4 11 5 12 165 7.4 0.1 7.8 7.3 06/25/2006 22:50:00 5.5 0.3 6.5 4.6 5.3 0.4 6.5 4.2 5.6 0.4 6.8 3.8 19 4 26 165 7.3 0.1 7.8 7 06/25/2006 23:00:00 4.9 0.4 5.7 3.8 4.4 0.7 5.7 2.6 5.2 0.4 6.1 4.2 16 4 20 165 7.8 0 7.8 7.5 06/25/2006 23:10:00 4.7 0.3 5.3 3.8 4.2 0.6 5.3 2.3 5 0.3 5.7 4.2 14 3 15 165 7.8 0 7.8 7.5 06/25/2006 23:20:00 4 0.4 4.9 3.4 2.5 0.6 4.6 1.5 4.4 0.3 5.3 3.8 8 2 14 165 7.6 0 7.8 7 06/25/2006 23:30:00 3.4 0.3 4.2 2.6 2 0.5 3.4 0.7 3.9 0.2 4.6 3 8 2 9 165 7.6 0 7.8 7 06/25/2006 23:40:00 3.6 0.3 4.2 3 2.9 0.7 4.2 1.1 4.1 0.2 4.6 3.8 15 6 12 165 7.6 0 7.8 7 06/25/2006 23:50:00 3.5 0.3 4.6 2.6 2.2 0.8 4.2 0.7 3.9 0.3 4.9 3 6 10 16 165 7.8 0 7.8 7.3 06/26/2006 00:00:00 3.3 0.4 4.2 2.6 3 0.7 4.2 1.5 3.7 0.4 4.6 2.6 347 6 356 165 7.6 0 8.3 7.5 06/26/2006 00:10:00 2.9 0.2 3.4 2.3 2.8 0.4 3.4 1.1 3.1 0.3 3.4 2.3 347 3 349 165 7.4 0 7.5 7.3 06/26/2006 00:20:00 2.8 0.3 3.4 1.9 1.6 0.5 3 0.7 2.9 0.3 3.4 2.3 354 5 351 165 7.4 0 7.5 7.3 06/26/2006 00:30:00 2.6 0.3 3.4 1.9 1.9 0.5 3.4 0.7 3 0.3 3.8 2.3 351 3 354 165 7.5 0 7.8 7.3 06/26/2006 00:40:00 2.7 0.3 3.4 1.9 1.8 0.7 3.4 0.7 3.2 0.3 4.2 2.6 355 5 357 165 7.7 0 8 7.5 06/26/2006 00:50:00 2.7 0.3 3.4 1.9 1.6 0.5 3 0.4 3.2 0.3 3.8 2.3 4 6 360 165 7.9 0 8 7.8 06/26/2006 01:00:00 2.7 0.3 3.4 2.3 1.5 0.5 3 0.7 3.2 0.4 4.2 2.6 2 5 12 165 8 0 8.3 7.8 06/26/2006 01:10:00 3 0.4 3.8 2.3 2.1 0.9 3.8 0.7 3.6 0.3 4.6 3 10 8 20 165 8 0 8.3 7.8 06/26/2006 01:20:00 3.4 0.3 3.8 2.6 3.4 0.3 4.2 2.6 3.9 0.2 4.6 3.4 28 5 22 165 8 0 8.3 7.8 06/26/2006 01:30:00 2.5 0.2 3 1.9 2.5 0.3 3.4 1.9 3.1 0.3 3.8 2.6 24 8 32 165 8 0 8.3 7.8 06/26/2006 01:40:00 2.2 0.6 3 0.7 2 0.8 3 0.4 2.6 0.6 3.4 1.1 20 3 16 165 7.6 0.1 8 7.5 06/26/2006 01:50:00 1.1 0.4 1.9 0.4 0.9 0.5 1.9 0.4 1.6 0.4 2.3 0.7 345 15 336 165 7.4 0 7.5 7.3 06/26/2006 02:00:00 1.8 0.4 2.3 1.1 1.2 0.5 2.6 0.4 2.3 0.4 3 1.5 347 6 355 165 7.4 0 7.5 7.3 06/26/2006 02:10:00 1.4 0.3 2.3 0.7 1.4 0.5 2.3 0.4 1.9 0.3 2.6 1.1 345 2 346 165 7.3 0 7.5 7.3 06/26/2006 02:20:00 0.9 0.2 1.5 0.4 0.5 0.2 1.5 0.4 1.4 0.2 1.9 0.7 351 5 344 165 7.3 0 7.5 7.3 06/26/2006 02:30:00 1 0.2 1.5 0.7 0.7 0.4 1.5 0.4 1.6 0.2 2.3 1.1 357 7 5 165 7.3 0 7.5 7.3 06/26/2006 02:40:00 1 0.2 1.9 0.4 0.9 0.4 1.9 0.4 1.6 0.3 1.9 0.7 353 11 36 165 7.1 0 7.3 7 06/26/2006 02:50:00 2 0.3 2.6 1.1 1.8 0.4 2.6 0.7 2.4 0.3 3 1.5 18 2 18 165 7.3 0 7.3 7 06/26/2006 03:00:00 2.1 0.3 3 1.5 2 0.4 3 0.7 2.6 0.3 3.4 2.3 27 7 34 165 7.3 0 7.5 7.3 06/26/2006 03:10:00 2.4 0.2 2.6 1.9 2.4 0.2 3 1.9 2.8 0.2 3.4 2.3 28 2 34 165 7.3 0 7.3 7.3 06/26/2006 03:20:00 2.6 0.3 3.4 1.9 2.6 0.3 3.4 1.9 3 0.3 3.4 2.3 30 2 29 165 7.3 0 7.5 7.3 06/26/2006 03:30:00 2.8 0.3 3.4 1.9 2.8 0.3 3.4 1.9 3.1 0.3 3.8 2.3 36 4 32 165 7.3 0 7.5 7.3 06/26/2006 03:40:00 2.4 0.2 3 1.9 2.2 0.4 3 0.7 2.9 0.2 3.4 2.3 21 6 23 165 7.3 0 7.5 7.3 06/26/2006 03:50:00 1.8 0.2 2.3 1.1 1.5 0.3 2.3 0.7 2.4 0.2 3 1.9 12 6 11 165 7.2 0 7.3 7 06/26/2006 04:00:00 1.5 0.3 2.3 0.7 1.5 0.3 2.3 0.7 2.1 0.2 2.6 1.5 31 2 32 165 7.2 0 7.3 7 06/26/2006 04:10:00 1.2 0.3 1.9 0.4 1.1 0.3 1.9 0.4 1.7 0.4 2.3 0.7 15 6 21 165 7.1 0 7.3 7 06/26/2006 04:20:00 1 0.3 1.5 0.4 0.7 0.4 1.5 0.4 1.6 0.3 2.3 0.7 10 9 22 165 7.3 0.1 7.5 7 06/26/2006 04:30:00 0.7 0.2 1.5 0.4 0.5 0.2 1.1 0.4 1.3 0.3 1.9 0.4 354 6 360 165 7.2 0 7.5 7 06/26/2006 04:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0.1 0.7 0.4 321 26 165 165 7.5 0 7.8 7.3 06/26/2006 04:50:00 0.5 0.2 1.5 0.4 0.5 0.2 1.5 0.4 0.7 0.4 1.5 0.4 251 15 247 165 7.7 0 8 7.5 06/26/2006 05:00:00 0.4 0.1 1.1 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 273 9 276 165 7.8 0 8 7.5 06/26/2006 05:10:00 0.7 0.4 1.9 0.4 0.6 0.5 1.9 0.4 0.7 0.6 1.9 0.4 261 18 242 165 7.9 0 8.3 7.8 06/26/2006 05:20:00 0.7 0.3 1.5 0.4 0.8 0.4 1.5 0.4 1.2 0.4 1.9 0.4 266 15 264 165 8.3 0.2 8.8 7.8 06/26/2006 05:30:00 0.5 0.2 1.1 0.4 0.5 0.2 1.1 0.4 0.4 0.2 1.1 0.4 295 6 282 165 9.2 0.2 9.6 8.5 06/26/2006 05:40:00 0.4 0.1 1.1 0.4 0.4 0 0.7 0.4 0.4 0.1 0.7 0.4 346 82 154 165 10.1 0.2 10.6 9.6 06/26/2006 05:50:00 0.4 0.2 1.1 0.4 0.4 0.2 1.1 0.4 0.6 0.4 1.9 0.4 185 26 157 165 9.8 0.1 10.1 9.3 06/26/2006 06:00:00 0.4 0 0.4 0.4 0.4 0 0.7 0.4 0.4 0 0.4 0.4 156 0 165 165 10.1 0.2 10.6 9.6 06/26/2006 06:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 156 0 165 165 10 0.2 10.6 9.6 06/26/2006 06:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 156 0 165 165 11.1 0.3 11.7 10.3 06/26/2006 06:30:00 0.4 0 0.4 0.4 0.6 0.2 1.1 0.4 0.5 0.2 1.1 0.4 184 61 165 165 11.1 0.2 11.7 10.6 06/26/2006 06:40:00 0.6 0.3 1.1 0.4 1.1 0.2 1.5 0.7 0.9 0.4 1.9 0.4 304 8 300 165 10.3 0.3 10.9 9.8 06/26/2006 06:50:00 0.6 0.2 1.5 0.4 1 0.2 1.5 0.4 1.1 0.2 1.5 0.4 326 12 319 165 10.8 0.2 11.4 10.3 06/26/2006 07:00:00 0.4 0.1 0.7 0.4 0.5 0.2 1.1 0.4 0.6 0.3 1.1 0.4 358 0 358 165 11.6 0.2 12.2 10.9 06/26/2006 07:10:00 0.4 0.1 1.1 0.4 0.4 0.1 1.1 0.4 0.4 0.2 1.1 0.4 358 0 358 165 12.2 0 12.5 11.9 06/26/2006 07:20:00 0.4 0.1 1.1 0.4 0.5 0.2 1.1 0.4 0.4 0.2 1.5 0.4 355 66 178 165 11.5 0.3 12.5 11.1 06/26/2006 07:30:00 0.9 0.6 2.6 0.4 1.1 0.7 2.6 0.4 1.1 0.7 2.3 0.4 58 69 116 165 12 0.2 12.5 11.4 06/26/2006 07:40:00 1.2 0.8 3 0.4 1.4 0.8 3 0.4 1.6 0.6 3 0.4 131 13 133 165 11.4 0.2 11.9 10.9 06/26/2006 07:50:00 0.8 0.5 2.3 0.4 1.2 0.5 2.6 0.4 1.2 0.6 2.6 0.4 141 8 160 165 11.2 0 11.4 11.1 06/26/2006 08:00:00 0.5 0.4 2.3 0.4 0.7 0.5 2.3 0.4 0.7 0.5 2.3 0.4 105 51 165 165 11.7 0.1 12.2 11.4 06/26/2006 08:10:00 0.6 0.4 1.9 0.4 1 0.5 2.3 0.4 1.1 0.5 2.3 0.4 140 23 145 165 12 0.2 12.5 11.4 06/26/2006 08:20:00 1.3 0.5 2.6 0.4 1.7 0.5 3.4 0.7 1.7 0.5 2.6 0.4 140 15 153 165 11.5 0 11.9 11.4 06/26/2006 08:30:00 0.9 0.5 2.3 0.4 1.4 0.6 2.6 0.4 1.5 0.5 2.6 0.4 137 23 151 165 11.1 0.2 11.7 10.6 06/26/2006 08:40:00 1.1 0.6 2.3 0.4 1.5 0.6 2.6 0.4 1.6 0.6 2.6 0.4 140 18 124 165 10.8 0.2 11.4 10.3 06/26/2006 08:50:00 0.9 0.6 2.6 0.4 1.3 0.6 3 0.4 1.3 0.6 2.6 0.4 121 17 135 165 11.2 0 11.4 10.9 06/26/2006 09:00:00 1.8 0.9 3.4 0.4 2.2 0.8 3.8 0.4 2.2 0.9 4.2 0.4 133 19 145 165 11.7 0.4 12.5 11.1 06/26/2006 09:10:00 2.1 0.7 4.6 0.4 2.4 0.6 4.2 1.1 2.4 0.6 4.2 1.1 146 15 158 165 12.1 0 12.5 11.7 06/26/2006 09:20:00 2.6 0.6 3.8 1.1 2.8 0.5 3.8 1.5 2.8 0.5 4.6 1.5 143 15 126 165 11.6 0 11.9 11.4 06/26/2006 09:30:00 2.8 0.6 4.6 1.5 3 0.5 4.6 1.9 3 0.5 4.2 1.5 138 14 134 165 11.3 0.2 11.7 10.9 06/26/2006 09:40:00 2.4 0.5 3.8 1.1 2.6 0.5 4.2 1.1 2.6 0.5 4.2 1.5 125 10 110 165 10.9 0 11.1 10.9 06/26/2006 09:50:00 2.5 0.6 4.2 0.4 2.7 0.6 4.2 0.7 2.8 0.6 3.8 1.1 139 17 152 165 11.8 0.5 12.5 10.9 06/26/2006 10:00:00 2.4 0.6 4.2 0.7 2.7 0.6 4.2 1.1 2.7 0.6 4.6 1.5 141 14 171 165 11.5 0.1 11.9 11.1 06/26/2006 10:10:00 2.3 0.6 3.8 0.4 2.6 0.5 3.8 1.1 2.8 0.5 4.2 1.1 130 15 141 165 11.2 0 11.4 10.9 06/26/2006 10:20:00 2.6 0.6 4.2 1.1 2.8 0.5 4.2 1.5 3 0.6 4.6 1.1 139 17 152 165 11.5 0.3 11.9 11.1 06/26/2006 10:30:00 2.8 0.6 4.9 1.5 3 0.6 4.6 1.9 2.9 0.6 4.6 1.5 137 14 151 165 11.7 0 11.9 11.4 06/26/2006 10:40:00 3.2 0.7 4.9 1.5 3.3 0.7 4.9 1.5 3.3 0.6 4.9 1.9 140 11 156 165 11.1 0.2 11.9 10.9 06/26/2006 10:50:00 3 0.6 4.6 0.4 3.2 0.6 4.9 1.9 3.2 0.5 4.6 1.5 141 14 149 165 11.1 0 11.7 10.9 06/26/2006 11:00:00 2.9 0.8 4.9 0.7 3 0.8 4.9 0.7 3.2 0.8 4.9 1.5 131 20 133 165 11.7 0 11.9 11.4 06/26/2006 11:10:00 2.4 0.7 4.6 0.7 2.6 0.7 4.6 0.7 2.7 0.7 5.3 1.1 141 13 139 165 11.2 0.3 11.7 10.9 06/26/2006 11:20:00 1.8 0.7 3.4 0.4 2 0.7 3.8 0.4 2.2 0.7 3.8 0.7 144 14 148 165 10.7 0 10.9 10.6 06/26/2006 11:30:00 1.8 0.5 2.6 0.7 2.1 0.4 3 1.1 2.2 0.4 3.4 0.7 140 17 150 165 10.5 0.1 10.9 10.3 06/26/2006 11:40:00 1.9 0.5 3 0.7 2.1 0.4 3 0.7 2.3 0.4 3.4 1.5 133 11 125 165 10.1 0 10.3 9.8 06/26/2006 11:50:00 2.1 0.4 3.4 0.7 2.4 0.4 3.4 1.5 2.5 0.3 3.4 1.9 142 11 154 165 10.2 0 10.9 9.8 06/26/2006 12:00:00 2 0.4 3.4 0.4 2.3 0.4 3.8 1.1 2.4 0.4 3.4 1.5 133 9 116 165 10.3 0 10.6 10.1 06/26/2006 12:10:00 2.2 0.5 3.4 1.1 2.4 0.4 3.8 1.5 2.5 0.4 3.8 1.5 134 9 137 165 10.3 0 10.6 10.3 06/26/2006 12:20:00 1.4 0.5 2.6 0.4 1.7 0.5 2.6 0.4 1.9 0.5 3 0.7 128 14 126 165 10.2 0 10.6 9.8 06/26/2006 12:30:00 1.2 0.5 2.3 0.4 1.5 0.5 2.6 0.4 1.6 0.4 2.6 0.4 120 13 124 165 10.1 0 10.6 9.8 06/26/2006 12:40:00 1.4 0.5 2.3 0.4 1.7 0.5 2.6 0.4 1.6 0.5 2.6 0.4 112 15 128 165 10.3 0.1 10.9 10.1 06/26/2006 12:50:00 1.4 0.4 2.6 0.4 1.7 0.4 2.6 0.4 2 0.4 3 1.1 136 12 153 165 10 0.1 10.3 9.6 06/26/2006 13:00:00 1.1 0.4 2.3 0.4 1.3 0.4 2.3 0.4 1.6 0.4 2.3 0.7 133 15 137 165 9.8 0.1 10.1 9.3 06/26/2006 13:10:00 2.1 0.7 3.4 0.4 2.3 0.6 3.4 0.7 2.4 0.6 3.8 0.4 142 13 133 165 9.8 0.1 9.8 9.3 06/26/2006 13:20:00 1.6 0.5 3 0.4 1.8 0.4 3 0.7 1.9 0.5 3 0.7 122 14 135 165 9.4 0 9.8 9 06/26/2006 13:30:00 1.2 0.5 2.6 0.4 1.4 0.5 2.6 0.4 1.6 0.5 2.6 0.4 119 12 102 165 9.3 0 9.6 9 06/26/2006 13:40:00 1.7 0.7 3 0.4 1.9 0.7 3.4 0.4 1.8 0.7 3 0.4 105 17 99 165 9.5 0.1 9.6 9.3 06/26/2006 13:50:00 1.3 0.5 2.6 0.4 1.5 0.5 2.6 0.4 1.4 0.6 2.6 0.4 121 15 116 165 9.6 0 9.8 9.3 06/26/2006 14:00:00 1.7 0.6 3 0.4 1.9 0.6 3 0.4 1.9 0.6 3 0.4 115 11 110 165 9.6 0 9.8 9.6 06/26/2006 14:10:00 2.2 0.4 3.4 0.7 2.4 0.4 3.4 1.5 2.5 0.5 3.8 1.1 128 14 137 165 9.7 0 9.8 9.6 06/26/2006 14:20:00 2.2 0.5 3.8 0.7 2.5 0.4 3.4 1.5 2.7 0.3 3.8 2.3 131 6 135 165 9.6 0 9.8 9.3 06/26/2006 14:30:00 1.5 0.5 2.6 0.4 1.7 0.5 3 0.7 2 0.4 3 1.1 136 7 132 165 9.3 0 9.6 9 06/26/2006 14:40:00 1.7 0.4 3 0.7 1.9 0.4 3 1.1 2.1 0.3 3 1.5 134 13 114 165 9.1 0 9.3 9 06/26/2006 14:50:00 2 0.3 3 1.1 2.2 0.3 3 1.5 2.5 0.3 3.4 1.5 151 9 139 165 9.2 0.1 9.6 9 06/26/2006 15:00:00 2.5 0.3 3 1.9 2.7 0.3 3.4 2.3 2.8 0.3 3.4 2.3 152 6 154 165 9 0 9.3 8.8 06/26/2006 15:10:00 2.8 0.2 3.4 2.3 2.9 0.2 3.4 2.6 3 0.2 3.4 2.6 155 4 150 165 9 0 9.6 9 06/26/2006 15:20:00 2.7 0.2 3 1.9 2.8 0.2 3.4 2.3 2.9 0.3 3.4 1.9 162 10 159 165 9 0 9.3 8.8 06/26/2006 15:30:00 2.7 0.4 3.4 1.5 2.8 0.3 3.8 1.9 2.9 0.3 3.4 2.3 171 5 171 165 9.1 0 9.6 9 06/26/2006 15:40:00 2.5 0.3 3.4 1.9 2.6 0.3 3.4 1.9 2.7 0.3 3.4 1.9 175 6 180 165 9.2 0 9.6 9 06/26/2006 15:50:00 2.5 0.5 3.4 1.5 2.6 0.4 3.4 1.9 2.8 0.4 3.8 1.9 179 2 178 165 9.2 0.1 9.6 9 06/26/2006 16:00:00 1.7 0.4 2.6 0.7 1.8 0.3 2.6 1.1 2.1 0.3 3 1.5 176 5 165 165 9.4 0.1 9.6 9 06/26/2006 16:10:00 2.4 0.4 3 1.1 2.5 0.3 3 1.5 2.7 0.4 3.4 1.5 181 8 178 165 9.5 0.1 10.1 9.3 06/26/2006 16:20:00 2.1 0.4 3 0.7 2.3 0.3 3 1.1 2.5 0.3 3.4 1.5 194 7 204 165 9.6 0.1 9.8 9 06/26/2006 16:30:00 1.7 0.5 3 0.4 1.9 0.4 2.6 0.7 2.1 0.4 3 1.1 192 9 193 165 9.6 0.1 10.1 9.3 06/26/2006 16:40:00 2.9 0.6 3.8 1.1 3 0.5 3.8 1.5 3 0.6 4.2 1.5 199 5 194 165 9.6 0 9.8 9.3 06/26/2006 16:50:00 3.5 0.2 3.8 3 3.7 0.2 4.2 3 3.9 0.2 4.6 3.4 193 2 198 165 9.6 0.1 10.3 9.3 06/26/2006 17:00:00 3.2 0.2 3.4 2.6 3.3 0.2 3.8 3 3.5 0.2 3.8 2.6 191 1 194 165 9.6 0.1 9.8 9.3 06/26/2006 17:10:00 3.4 0.2 3.8 3 3.6 0.2 4.2 3 3.8 0.3 4.6 3 196 2 195 165 9.8 0 10.1 9.3 06/26/2006 17:20:00 3.7 0.2 4.2 2.6 3.9 0.2 4.2 3 4.1 0.3 4.6 3 192 3 193 165 9.8 0 10.1 9.6 06/26/2006 17:30:00 3.5 0.3 4.2 2.6 3.6 0.3 4.2 2.6 3.8 0.4 4.6 2.6 191 5 193 165 9.7 0.1 10.3 9.3 06/26/2006 17:40:00 3.7 0.3 4.6 2.6 3.8 0.3 4.6 2.6 4 0.3 4.6 3.4 182 3 178 165 9.6 0.1 9.8 9.3 06/26/2006 17:50:00 3.6 0.3 4.2 2.3 3.6 0.3 4.2 2.3 3.9 0.3 4.6 3 178 5 177 165 9.6 0.1 9.8 9.3 06/26/2006 18:00:00 3.4 0.4 4.2 2.3 3.5 0.3 4.2 2.6 3.8 0.4 4.6 3 174 6 178 165 9.6 0.2 9.8 9 06/26/2006 18:10:00 3.5 0.3 4.6 2.6 3.5 0.3 4.2 3 3.8 0.3 4.6 3 170 5 157 165 9.6 0.2 9.8 9 06/26/2006 18:20:00 3.4 0.3 3.8 2.3 3.4 0.3 3.8 2.6 3.6 0.2 4.2 3 168 4 168 165 9.5 0.2 9.8 9 06/26/2006 18:30:00 3.5 0.3 4.2 2.6 3.4 0.3 3.8 2.6 3.5 0.3 4.2 2.6 164 7 165 165 9.5 0 9.6 8.8 06/26/2006 18:40:00 3.1 0.3 3.8 1.9 3.1 0.3 3.4 1.9 3.1 0.4 3.8 1.9 167 5 165 165 9.6 0 9.6 9 06/26/2006 18:50:00 2.6 0.3 3 1.5 2.6 0.3 3.4 1.9 2.8 0.3 3.4 1.9 169 4 166 165 9.6 0.1 9.8 9 06/26/2006 19:00:00 2.6 0.4 3.8 1.5 2.6 0.4 3.4 1.5 2.5 0.2 3.4 1.9 169 9 179 165 9.6 0 9.6 9 06/26/2006 19:10:00 2.7 0.4 3.4 1.9 2.7 0.3 3.4 1.9 2.8 0.3 3.4 2.3 167 5 169 165 9.5 0 9.8 9.3 06/26/2006 19:20:00 2.8 0.3 3.4 2.3 2.8 0.3 3.4 2.3 2.8 0.2 3.4 2.3 166 9 170 165 9.5 0 9.8 9 06/26/2006 19:30:00 3 0.3 3.8 2.3 2.9 0.3 3.8 2.3 3.1 0.3 3.8 2.3 162 3 165 165 9.6 0 9.8 9.3 06/26/2006 19:40:00 3.4 0.4 4.2 2.3 3.3 0.4 4.2 2.3 3.3 0.4 4.2 2.3 166 6 166 165 9.6 0 9.8 9.3 06/26/2006 19:50:00 2.7 0.4 3.8 1.9 2.8 0.3 3.8 1.9 2.8 0.3 3.8 1.9 162 10 163 165 9.7 0 9.8 9.3 06/26/2006 20:00:00 3.8 0.3 4.6 3 3.7 0.3 4.2 3 3.8 0.3 4.6 3 163 3 164 165 9.8 0 10.1 9.6 06/26/2006 20:10:00 3.5 0.3 4.2 2.6 3.5 0.3 4.2 2.6 3.5 0.3 4.2 2.6 163 11 165 165 9.7 0 9.8 9.6 06/26/2006 20:20:00 3.8 0.4 4.6 2.6 3.6 0.3 4.2 2.6 3.7 0.3 4.2 3 166 11 164 165 9.6 0 9.8 9.3 06/26/2006 20:30:00 3.2 0.4 4.2 1.9 3.2 0.3 3.8 2.3 3.2 0.3 4.2 2.3 160 5 155 165 9.6 0 9.8 9.3 06/26/2006 20:40:00 3.2 0.4 4.2 1.9 3.2 0.4 4.2 2.3 3.3 0.4 4.6 2.6 150 9 151 165 9.6 0 9.8 9.3 06/26/2006 20:50:00 3.1 0.3 4.2 2.6 3.1 0.3 4.2 2.6 3.3 0.2 3.8 2.6 144 6 151 165 9.6 0.1 9.6 9 06/26/2006 21:00:00 2.8 0.5 3.8 1.5 2.9 0.4 3.8 1.9 3 0.4 3.8 1.9 147 8 148 165 9.4 0 9.8 9 06/26/2006 21:10:00 2.3 0.4 3 1.1 2.4 0.4 3.4 1.5 2.6 0.3 3.4 1.9 141 8 139 165 9.4 0 9.6 9 06/26/2006 21:20:00 2 0.4 2.6 1.1 2.2 0.3 3 1.5 2.2 0.2 2.6 1.1 141 9 145 165 9.4 0 9.6 9 06/26/2006 21:30:00 1.6 0.4 2.6 0.7 1.9 0.4 2.6 1.1 2.1 0.3 3 1.5 151 8 159 165 9.4 0 9.6 9 06/26/2006 21:40:00 0.8 0.4 1.9 0.4 1 0.4 1.9 0.4 1.2 0.5 2.3 0.4 155 8 154 165 9.3 0 9.3 9 06/26/2006 21:50:00 0.4 0.1 1.1 0.4 0.4 0.2 1.1 0.4 0.5 0.2 1.1 0.4 175 3 176 165 9.3 0 9.6 8.8 06/26/2006 22:00:00 0.5 0.3 1.1 0.4 0.6 0.3 1.1 0.4 0.7 0.2 1.1 0.4 190 3 189 165 9.5 0.1 9.8 9 06/26/2006 22:10:00 0.4 0.2 1.1 0.4 0.4 0 0.4 0.4 0.4 0.1 1.1 0.4 195 7 214 165 9.6 0.1 10.1 9 06/26/2006 22:20:00 0.8 0.4 1.5 0.4 0.9 0.5 1.9 0.4 1.2 0.6 2.3 0.4 208 3 214 165 10 0.2 10.3 9.6 06/26/2006 22:30:00 0.4 0.1 1.1 0.4 0.4 0.2 1.1 0.4 0.5 0.2 1.1 0.4 206 0 206 165 10 0.2 10.3 9.6 06/26/2006 22:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 237 32 165 165 9.9 0.2 10.3 9.3 06/26/2006 22:50:00 0.6 0.3 1.5 0.4 0.7 0.3 1.5 0.4 1.1 0.4 1.9 0.4 315 18 312 165 9.5 0.2 9.8 9 06/26/2006 23:00:00 1.5 0.5 3 0.4 1.5 0.5 3 0.7 1.8 0.4 2.6 1.1 319 8 317 165 9.3 0 9.6 8.8 06/26/2006 23:10:00 2.8 0.5 3.8 1.1 2.8 0.5 3.8 1.5 2.7 0.4 3.8 1.5 313 7 305 165 9.2 0 9.6 8.8 06/26/2006 23:20:00 3.1 0.4 3.8 1.9 3.2 0.4 4.2 1.9 2.6 0.3 3.4 1.5 302 5 305 165 9.2 0.1 9.3 8.8 06/26/2006 23:30:00 2.9 0.3 3.8 2.3 3 0.3 3.8 2.3 2.6 0.3 3.4 1.5 303 4 304 165 9.2 0.1 9.6 8.8 06/26/2006 23:40:00 3.5 0.4 4.6 2.6 3.6 0.4 4.6 3 2.6 0.4 4.2 1.9 296 4 295 165 9.4 0 9.6 9 06/26/2006 23:50:00 3.3 0.6 4.2 1.9 3.4 0.5 4.2 1.9 2.6 0.4 3.8 1.9 301 6 300 165 9.5 0.1 9.6 9 06/27/2006 00:00:00 2.2 0.4 3.4 1.5 2.3 0.4 3.4 1.5 2.3 0.3 3 1.5 314 7 314 165 9.4 0 9.6 9 06/27/2006 00:10:00 2 0.2 2.6 1.5 2.1 0.4 3 0.7 2.3 0.2 2.6 1.9 339 18 323 165 9 0 9.6 8.8 06/27/2006 00:20:00 1.2 0.4 1.9 0.4 1.1 0.5 1.9 0.4 1.7 0.3 2.6 1.1 16 1 12 165 9 0 9.3 8.8 06/27/2006 00:30:00 0.5 0.4 1.9 0.4 0.5 0.4 1.9 0.4 0.7 0.6 2.3 0.4 104 66 16 165 9.2 0 9.6 9 06/27/2006 00:40:00 0.4 0 0.4 0.4 0.4 0 0.7 0.4 0.4 0 0.7 0.4 76 47 165 165 9.1 0 9.6 9 06/27/2006 00:50:00 0.4 0.1 1.1 0.4 0.4 0.1 0.7 0.4 0.5 0.2 1.1 0.4 137 7 135 165 9.1 0 9.3 9 06/27/2006 01:00:00 0.6 0.2 1.1 0.4 0.5 0.2 1.1 0.4 1 0.2 1.5 0.4 160 6 155 165 9.3 0 9.6 9 06/27/2006 01:10:00 1 0.2 1.5 0.4 1 0.3 1.5 0.4 1.4 0.2 1.9 1.1 187 6 189 165 9.5 0 9.6 9 06/27/2006 01:20:00 1.4 0.3 1.9 0.7 1.4 0.3 1.9 0.7 1.8 0.2 2.3 1.5 168 7 167 165 9.6 0 9.6 9.3 06/27/2006 01:30:00 1 0.4 1.9 0.4 1 0.4 1.9 0.4 1.4 0.3 2.3 0.7 168 5 178 165 9.5 0 9.6 9.3 06/27/2006 01:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 1 0.2 1.5 0.4 165 1 165 165 9.4 0 9.6 9.3 06/27/2006 01:50:00 0.4 0.3 1.5 0.4 0.4 0.2 1.5 0.4 0.9 0.4 1.5 0.4 167 3 177 165 9.4 0 9.6 9.3 06/27/2006 02:00:00 0.9 0.4 1.5 0.4 0.9 0.3 1.5 0.4 1.1 0.3 1.9 0.4 176 7 178 165 9.5 0 9.6 9 06/27/2006 02:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 184 1 165 165 9.4 0 9.6 9.3 06/27/2006 02:20:00 0.4 0 0.4 0.4 0.4 0 0.7 0.4 0.4 0 0.4 0.4 182 9 165 165 9.4 0 9.6 9.3 06/27/2006 02:30:00 0.5 0.2 1.1 0.4 0.5 0.3 1.1 0.4 0.6 0.4 1.5 0.4 168 2 165 165 9.3 0 9.6 9 06/27/2006 02:40:00 0.5 0.3 1.1 0.4 0.6 0.3 1.5 0.4 0.8 0.5 1.9 0.4 238 32 256 165 9.2 0 9.3 9 06/27/2006 02:50:00 1.2 0.4 1.9 0.4 1.4 0.4 1.9 0.4 1.7 0.3 2.3 0.7 267 5 264 165 9 0 9 8.8 06/27/2006 03:00:00 1.2 0.4 1.9 0.4 1.4 0.3 2.3 0.7 1.6 0.3 2.3 1.1 269 3 274 165 8.9 0 9 8.5 06/27/2006 03:10:00 1.8 0.6 3 0.7 2 0.6 3 0.7 2.1 0.6 3.4 1.1 272 5 277 165 9 0 9.3 8.5 06/27/2006 03:20:00 2.4 0.5 3.4 1.1 2.6 0.5 3.8 1.1 2.8 0.5 3.8 1.9 273 6 277 165 8.5 0.1 8.8 8 06/27/2006 03:30:00 1.2 0.6 2.6 0.4 1.2 0.7 2.6 0.4 1.7 0.5 2.6 0.7 277 8 285 165 8.5 0 8.8 8.3 06/27/2006 03:40:00 1.6 0.6 3 0.4 1.7 0.6 3 0.4 2 0.5 3.4 0.7 276 12 284 165 8.5 0 8.8 8.3 06/27/2006 03:50:00 0.8 0.4 2.3 0.4 0.8 0.5 1.9 0.4 1 0.5 2.6 0.4 271 24 276 165 8.5 0.1 8.8 8 06/27/2006 04:00:00 0.5 0.3 1.5 0.4 0.5 0.2 1.5 0.4 1 0.4 1.9 0.4 240 15 227 165 8.8 0 9 8.3 06/27/2006 04:10:00 0.6 0.4 1.9 0.4 0.6 0.4 1.9 0.4 0.6 0.4 1.9 0.4 193 22 194 165 8.9 0.1 9 8.5 06/27/2006 04:20:00 0.4 0.2 1.1 0.4 0.5 0.2 1.5 0.4 0.9 0.4 1.9 0.4 246 11 240 165 8.7 0.2 9 8.3 06/27/2006 04:30:00 0.8 0.3 1.5 0.4 0.7 0.4 1.5 0.4 1.1 0.3 1.5 0.4 238 14 236 165 8.8 0 9 8.3 06/27/2006 04:40:00 1.3 0.4 2.3 0.4 1.4 0.4 1.9 0.4 1.7 0.3 2.3 1.1 250 2 244 165 8.7 0.1 9 8.3 06/27/2006 04:50:00 1.2 0.3 1.9 0.4 1.5 0.4 2.3 0.4 2 0.3 2.6 1.1 257 8 262 165 8.5 0.1 8.5 8 06/27/2006 05:00:00 1.5 0.3 2.3 0.4 1.7 0.2 2.6 1.1 2 0.2 2.6 1.5 267 4 270 165 8.5 0 8.8 8.3 06/27/2006 05:10:00 1.4 0.4 2.3 0.4 1.6 0.3 2.3 0.7 2.1 0.3 3 1.5 266 5 270 165 8.5 0 8.5 8.3 06/27/2006 05:20:00 1.3 0.3 1.9 0.4 1.4 0.3 2.3 0.7 1.9 0.3 2.6 1.1 251 12 264 165 8.4 0 8.5 8.3 06/27/2006 05:30:00 1.9 0.5 3 1.1 1.9 0.5 3 0.7 2.3 0.5 3 1.1 229 2 229 165 8.7 0 9 8.3 06/27/2006 05:40:00 2 0.3 2.6 1.1 1.9 0.3 2.6 1.1 2.3 0.3 3 1.5 230 4 237 165 8.9 0 9 8.8 06/27/2006 05:50:00 1.4 0.4 2.6 0.4 1.5 0.4 2.3 0.4 1.4 0.6 2.6 0.4 242 10 245 165 9 0 9 8.8 06/27/2006 06:00:00 1 0.4 1.9 0.4 1.2 0.4 2.3 0.4 1.8 0.3 2.6 0.7 258 11 239 165 9 0 9.3 8.8 06/27/2006 06:10:00 0.6 0.3 1.5 0.4 0.6 0.3 1.9 0.4 1.3 0.4 2.3 0.4 245 16 262 165 9 0 9.3 8.8 06/27/2006 06:20:00 0.9 0.4 2.3 0.4 0.7 0.4 2.3 0.4 1.3 0.4 2.6 0.4 237 4 251 165 9.5 0.1 9.8 9 06/27/2006 06:30:00 2.7 0.6 4.2 1.5 2.7 0.5 3.8 1.5 2.8 0.5 3.8 1.9 245 6 246 165 9.7 0.2 10.1 9 06/27/2006 06:40:00 2.3 0.5 3 1.1 2.3 0.5 3 0.7 2.5 0.5 3.4 1.1 231 8 233 165 10.1 0.2 10.6 9.3 06/27/2006 06:50:00 1.8 0.4 2.6 0.7 1.7 0.4 2.6 0.4 2.3 0.3 3 1.1 232 5 237 165 10.1 0.2 10.9 9.6 06/27/2006 07:00:00 1.6 0.4 2.6 0.7 1.6 0.5 2.6 0.4 2.2 0.3 3 1.5 222 5 229 165 10.4 0.1 10.9 9.8 06/27/2006 07:10:00 1.5 0.4 2.3 0.7 1.4 0.4 2.6 0.4 2 0.3 3 1.5 213 9 227 165 10.6 0 10.9 10.3 06/27/2006 07:20:00 1.2 0.6 2.6 0.4 1.1 0.6 2.6 0.4 1.8 0.5 3 0.7 217 8 223 165 10.1 0.1 10.9 9.8 06/27/2006 07:30:00 1 0.5 2.3 0.4 1.1 0.6 2.6 0.4 1.7 0.5 2.6 0.4 245 20 234 165 10.5 0.3 10.9 9.8 06/27/2006 07:40:00 1.4 0.4 2.6 0.7 1.6 0.4 2.6 0.7 2 0.4 3 1.1 276 17 242 165 11 0.2 11.4 10.6 06/27/2006 07:50:00 1.9 0.5 3 0.4 2 0.5 3 0.4 1.9 0.4 3 1.1 295 11 296 165 11.2 0 11.4 10.9 06/27/2006 08:00:00 2 0.4 3 0.7 2.2 0.4 3.4 1.1 1.9 0.4 3 1.1 302 9 309 165 11.3 0 11.7 10.9 06/27/2006 08:10:00 1.7 0.4 2.6 0.4 2 0.4 3 0.7 1.9 0.4 3 1.1 313 11 311 165 11.6 0.2 11.9 11.1 06/27/2006 08:20:00 1.2 0.5 2.3 0.4 1.5 0.4 2.3 0.4 1.5 0.4 2.3 0.4 326 13 310 165 12.5 0.3 13 11.9 06/27/2006 08:30:00 1 0.4 1.9 0.4 1.4 0.4 2.3 0.4 1.2 0.4 1.9 0.4 303 12 300 165 13.2 0 13.5 13 06/27/2006 08:40:00 0.8 0.6 3 0.4 1 0.7 3.4 0.4 1 0.6 3 0.4 303 90 184 165 13.1 0.2 13.5 12.7 06/27/2006 08:50:00 0.9 0.6 2.6 0.4 1.2 0.7 3.4 0.4 1.1 0.7 3.8 0.4 100 56 95 165 13.4 0.5 14.1 12.7 06/27/2006 09:00:00 1.5 0.6 3 0.4 1.8 0.5 3 0.7 1.8 0.6 3.4 0.4 151 20 141 165 13.1 0.4 14.1 12.7 06/27/2006 09:10:00 1.8 0.7 3.8 0.4 2.1 0.7 3.8 0.4 2.2 0.6 3.4 0.4 126 26 110 165 12.9 0 13 12.7 06/27/2006 09:20:00 1.8 0.5 3 0.4 2.1 0.4 3.4 1.1 2.4 0.4 3.8 1.5 145 23 118 165 12.6 0 13 12.5 06/27/2006 09:30:00 1.4 0.8 3.4 0.4 1.7 0.7 3.8 0.4 1.9 0.7 3.8 0.4 167 24 159 165 12.6 0.2 13 12.5 06/27/2006 09:40:00 1.3 0.7 3 0.4 1.7 0.7 3.4 0.4 1.8 0.6 3.4 0.4 138 35 154 165 12.9 0.1 13.5 12.7 06/27/2006 09:50:00 1.1 0.7 3 0.4 1.5 0.7 3 0.4 1.5 0.7 3.4 0.4 144 58 174 165 13.4 0.2 14.1 13 06/27/2006 10:00:00 1.2 0.7 2.6 0.4 1.7 0.6 3 0.4 1.7 0.6 3.4 0.4 130 30 165 165 14.2 0.1 14.9 14.1 06/27/2006 10:10:00 1.8 0.9 4.2 0.4 2.2 0.8 4.2 0.4 2.3 0.7 4.6 0.4 139 27 110 165 13.7 0.2 14.6 13.3 06/27/2006 10:20:00 1.1 0.8 3 0.4 1.6 0.7 3.4 0.4 1.7 0.8 3.4 0.4 117 33 163 165 13 0.2 13.8 12.7 06/27/2006 10:30:00 0.9 0.6 2.6 0.4 1.3 0.6 2.6 0.4 1.2 0.7 3 0.4 85 61 85 165 13.7 0.5 14.9 13 06/27/2006 10:40:00 1.7 0.7 3 0.4 1.9 0.6 3.4 0.4 1.8 0.8 3.4 0.4 138 32 107 165 14.3 0.6 15.5 13.5 06/27/2006 10:50:00 2 0.6 3.4 0.4 2.2 0.6 3.8 0.4 2.3 0.5 3.8 1.1 108 22 96 165 13.7 0.2 14.6 13.3 06/27/2006 11:00:00 2.5 0.8 4.2 0.4 2.7 0.7 4.6 0.7 2.8 0.7 4.6 0.7 132 17 138 165 13.5 0.2 14.6 13 06/27/2006 11:10:00 2.4 0.8 4.2 0.4 2.6 0.7 4.2 0.4 2.6 0.6 4.6 1.1 149 17 158 165 13.6 0.3 14.6 13.3 06/27/2006 11:20:00 2.6 0.8 4.9 0.4 2.9 0.7 4.9 0.7 3 0.6 4.9 1.5 141 17 127 165 13.7 0.2 14.6 13.3 06/27/2006 11:30:00 2.1 1 4.9 0.4 2.4 0.9 4.6 0.4 2.6 0.9 4.9 0.4 135 23 135 165 13.9 0 14.6 13.5 06/27/2006 11:40:00 1.9 1 4.6 0.4 2.2 1 4.2 0.4 2.5 0.7 4.2 1.1 118 18 132 165 14.1 0.3 15.2 13.5 06/27/2006 11:50:00 3 0.6 4.6 1.5 3.2 0.5 4.6 1.9 3.2 0.6 5.3 1.9 124 19 151 165 14.6 0 15.2 14.4 06/27/2006 12:00:00 2.6 0.7 4.6 1.1 2.8 0.6 4.6 1.5 2.9 0.6 4.6 1.5 125 14 110 165 14.2 0.1 14.9 13.8 06/27/2006 12:10:00 2.8 0.7 4.9 0.7 3 0.6 4.6 1.5 3.2 0.5 4.6 1.9 131 10 158 165 14.1 0.1 14.9 13.8 06/27/2006 12:20:00 3.1 0.7 4.9 1.1 3.3 0.7 4.9 1.5 3.3 0.8 5.3 1.5 127 14 132 165 14.2 0.1 14.9 13.8 06/27/2006 12:30:00 2.7 0.6 4.2 1.1 2.9 0.6 4.6 1.5 3.1 0.6 4.6 1.5 128 11 125 165 13.9 0 14.6 13.8 06/27/2006 12:40:00 2.4 0.8 4.9 0.4 2.7 0.7 4.9 1.1 2.8 0.7 4.6 1.1 131 11 136 165 14.2 0.1 14.9 13.8 06/27/2006 12:50:00 2 0.8 4.2 0.4 2.3 0.7 4.2 0.7 2.4 0.7 4.2 0.4 128 15 135 165 14.7 0.1 15.5 14.4 06/27/2006 13:00:00 2.9 0.8 4.9 0.7 3.1 0.7 4.9 1.1 3 0.8 5.3 1.5 125 22 126 165 15.2 0.1 15.7 14.4 06/27/2006 13:10:00 3.1 1 5.7 1.1 3.2 0.8 5.3 1.5 3.3 0.8 5.3 1.5 130 20 171 165 15.4 0 15.7 15.2 06/27/2006 13:20:00 2.8 0.7 4.9 0.7 3 0.6 4.9 1.5 3 0.6 5.3 1.5 139 16 159 165 15.5 0 16 15.2 06/27/2006 13:30:00 2.4 0.8 4.2 0.4 2.7 0.7 4.6 1.1 3 0.6 4.6 1.5 127 19 151 165 15.2 0 15.7 15.2 06/27/2006 13:40:00 2.8 0.8 4.6 1.1 3 0.8 4.6 1.1 3 0.8 4.6 1.1 142 15 165 165 15.4 0 15.7 15.2 06/27/2006 13:50:00 3 0.9 4.9 0.4 3.2 0.9 4.9 0.7 3.2 0.8 5.3 0.7 137 17 143 165 15.3 0.1 15.7 15.2 06/27/2006 14:00:00 3.2 0.7 4.9 0.7 3.2 0.6 4.9 1.5 3.4 0.6 4.9 1.9 134 17 125 165 15.4 0 15.7 15.2 06/27/2006 14:10:00 3.1 0.7 4.6 1.1 3.3 0.7 4.9 1.5 3.3 0.7 4.9 1.5 136 16 107 165 15.5 0 15.7 15.2 06/27/2006 14:20:00 2.9 0.5 4.6 1.5 3.1 0.5 4.6 1.5 3.2 0.5 4.6 1.9 143 14 129 165 15.5 0 15.7 15.2 06/27/2006 14:30:00 3 0.6 4.6 1.1 3.1 0.6 4.9 1.5 3.1 0.5 4.6 1.5 137 16 127 165 15.5 0 15.7 15.2 06/27/2006 14:40:00 2.9 0.7 4.9 1.1 3.1 0.6 4.6 1.5 3.1 0.7 4.9 1.5 140 12 138 165 15.7 0.1 16.3 15.5 06/27/2006 14:50:00 2.9 0.7 4.9 1.1 3.2 0.6 4.9 1.9 3.1 0.7 5.7 1.1 135 13 138 165 15.7 0 16.3 15.5 06/27/2006 15:00:00 2.5 0.7 4.2 0.7 2.8 0.6 4.2 1.1 2.7 0.7 4.2 0.7 131 16 139 165 15.6 0 16 15.5 06/27/2006 15:10:00 2.5 0.6 3.8 1.5 2.7 0.6 4.2 1.5 2.9 0.6 4.6 1.5 148 16 151 165 15.5 0 16 15.2 06/27/2006 15:20:00 2.7 0.7 4.2 0.7 2.9 0.6 4.6 1.5 3 0.6 4.6 1.1 133 17 139 165 15.6 0 16 15.2 06/27/2006 15:30:00 2.3 0.6 3.8 0.7 2.6 0.5 3.8 1.1 2.6 0.5 3.8 1.5 154 15 179 165 15.5 0.2 16 15.2 06/27/2006 15:40:00 2.3 0.6 4.2 1.1 2.6 0.5 3.8 1.5 2.6 0.6 4.2 1.5 138 16 137 165 15.8 0 16.3 15.5 06/27/2006 15:50:00 2.2 0.7 3.8 0.4 2.6 0.6 4.2 1.1 2.7 0.6 4.6 1.1 138 12 141 165 15.7 0.1 16 15.5 06/27/2006 16:00:00 1.9 0.8 3.4 0.4 2.3 0.7 3.8 0.7 2.2 0.7 3.8 0.7 141 14 149 165 15.1 0.2 15.7 14.6 06/27/2006 16:10:00 1.4 0.8 3.8 0.4 1.7 0.7 3.8 0.4 1.8 0.7 3.8 0.4 123 28 154 165 15.3 0.2 16 14.9 06/27/2006 16:20:00 2.5 0.7 4.6 1.1 2.7 0.7 4.6 1.5 2.8 0.6 4.6 1.5 141 18 153 165 15.5 0.3 16 15.2 06/27/2006 16:30:00 1.7 0.6 3 0.4 2.1 0.5 3.4 0.7 2.2 0.6 3.4 0.7 141 11 148 165 15.2 0.1 15.5 14.9 06/27/2006 16:40:00 1.9 0.7 3.8 0.4 2.3 0.6 4.2 1.1 2.4 0.5 3.8 1.1 141 11 139 165 15.7 0 16 15.5 06/27/2006 16:50:00 1.9 0.5 3 0.4 2.3 0.4 3.4 1.1 2.3 0.4 3.4 1.1 135 13 133 165 15.5 0 16 15.2 06/27/2006 17:00:00 2 0.6 3.8 0.7 2.3 0.5 3.8 1.1 2.4 0.5 3.8 1.5 131 16 121 165 15.7 0 16 15.2 06/27/2006 17:10:00 1.9 0.5 3.4 0.7 2.3 0.4 3.4 1.1 2.1 0.5 3.4 0.7 131 19 154 165 15.8 0.1 16.3 15.5 06/27/2006 17:20:00 1.3 0.7 3.4 0.4 1.9 0.5 3.4 1.1 2 0.5 3.4 0.4 139 26 165 165 15.7 0 16 15.5 06/27/2006 17:30:00 1.8 0.6 3.4 0.4 2.2 0.4 3.4 1.1 2.3 0.5 3.8 1.1 135 15 141 165 15.7 0 16 15.5 06/27/2006 17:40:00 1 0.5 2.3 0.4 1.5 0.4 2.6 0.4 1.6 0.4 2.6 0.4 134 15 149 165 15.2 0 15.5 15.2 06/27/2006 17:50:00 0.9 0.5 2.3 0.4 1.3 0.6 2.6 0.4 1.4 0.6 2.6 0.4 124 19 128 165 15.3 0.1 15.7 15.2 06/27/2006 18:00:00 0.8 0.5 2.3 0.4 1.3 0.6 2.6 0.4 1.5 0.4 2.6 0.4 123 17 134 165 15.2 0 15.5 15.2 06/27/2006 18:10:00 0.5 0.3 1.9 0.4 1.1 0.4 2.3 0.4 1.1 0.5 2.3 0.4 111 13 101 165 15.4 0 15.7 15.2 06/27/2006 18:20:00 0.9 0.5 1.9 0.4 1.4 0.5 2.6 0.4 1.4 0.5 2.3 0.4 108 7 116 165 15.5 0 15.7 15.5 06/27/2006 18:30:00 1.3 0.6 3 0.4 1.9 0.5 3 0.4 2.1 0.5 3.4 1.1 99 12 117 165 15.4 0 15.7 15.2 06/27/2006 18:40:00 1.3 0.5 2.3 0.4 1.8 0.4 3 0.7 1.7 0.5 2.6 0.4 122 10 125 165 15.4 0 15.7 14.9 06/27/2006 18:50:00 0.8 0.4 1.9 0.4 1.3 0.4 2.3 0.4 1.2 0.3 1.9 0.4 103 14 119 165 15.7 0 16 15.5 06/27/2006 19:00:00 0.4 0.2 1.5 0.4 0.9 0.4 1.9 0.4 0.9 0.5 1.9 0.4 101 12 110 165 15.9 0 16.3 15.7 06/27/2006 19:10:00 0.5 0.2 1.5 0.4 0.8 0.5 1.9 0.4 0.7 0.5 1.9 0.4 90 5 99 165 16 0.1 16.3 15.7 06/27/2006 19:20:00 1.2 0.7 3 0.4 1.5 0.6 2.6 0.4 1.3 0.7 3 0.4 350 47 10 165 16.5 0 16.8 16.3 06/27/2006 19:30:00 1.6 0.7 3.4 0.4 1.9 0.7 3.4 0.4 1.8 0.6 3.4 0.4 325 19 322 165 16.3 0 16.6 16.3 06/27/2006 19:40:00 1.2 0.6 2.6 0.4 1.5 0.6 3 0.4 1.6 0.5 3 0.4 336 21 341 165 16.8 0 16.8 16.3 06/27/2006 19:50:00 1.5 0.6 3 0.4 1.7 0.5 3 0.4 2 0.5 3.4 0.7 336 15 358 165 16.5 0 16.8 16.3 06/27/2006 20:00:00 2.1 0.5 3.8 0.7 2.4 0.4 3.4 1.1 2.1 0.4 3 0.7 306 20 307 165 15.9 0.2 16.6 15.5 06/27/2006 20:10:00 2.4 0.4 3.4 1.1 2.7 0.4 3.4 1.5 2.2 0.5 3.4 0.7 303 16 297 165 15.4 0.1 15.7 14.9 06/27/2006 20:20:00 2.9 0.5 4.2 1.1 3 0.5 4.2 1.5 2.6 0.5 3.8 1.5 303 13 303 165 15.2 0.1 15.5 14.6 06/27/2006 20:30:00 3.2 0.5 4.2 1.1 3.4 0.5 4.2 1.5 2.9 0.5 4.2 1.5 292 8 293 165 14.8 0 15.2 14.4 06/27/2006 20:40:00 3.9 0.4 4.9 2.6 4.1 0.5 4.9 2.6 3.5 0.7 4.9 1.9 288 5 282 165 14.6 0 14.9 14.4 06/27/2006 20:50:00 3.8 0.5 4.9 2.3 4 0.5 4.9 2.6 3.5 0.7 4.9 1.9 284 7 287 165 14.1 0 14.4 13.8 06/27/2006 21:00:00 4.2 0.4 4.9 2.6 4.6 0.3 5.3 3.8 4.4 0.4 5.3 3 274 4 276 165 13.8 0 14.1 13.5 06/27/2006 21:10:00 4.3 0.4 4.9 3 4.7 0.3 5.7 3.8 4.4 0.4 5.3 3.4 272 3 272 165 13.3 0.1 13.8 13 06/27/2006 21:20:00 3.9 0.4 4.9 2.6 4.3 0.4 5.3 3.4 3.9 0.4 4.9 2.6 273 4 273 165 12.5 0.2 13 11.9 06/27/2006 21:30:00 2.9 0.6 4.6 1.5 3.7 0.4 4.9 2.6 3.6 0.3 4.2 3 265 8 277 165 12.3 0.1 12.5 11.9 06/27/2006 21:40:00 3 0.4 3.8 1.9 3.8 0.4 4.9 2.6 4.1 0.4 4.9 3 260 6 254 165 12.3 0 12.7 11.9 06/27/2006 21:50:00 3.3 0.6 4.6 1.9 4 0.5 5.3 2.6 4 0.5 4.9 3 265 6 271 165 12.3 0 12.5 11.9 06/27/2006 22:00:00 2.4 0.5 3.4 1.1 3.1 0.4 3.8 2.3 3.1 0.4 3.8 2.3 259 7 246 165 12.5 0 12.7 12.2 06/27/2006 22:10:00 2.2 0.5 3.4 1.1 2.8 0.4 3.8 1.9 2.9 0.5 4.2 1.9 262 6 266 165 12.5 0 12.7 12.2 06/27/2006 22:20:00 2.1 0.6 3.8 0.7 2.6 0.5 3.8 1.5 2.6 0.4 3.4 1.9 266 7 283 165 12.6 0 12.7 12.5 06/27/2006 22:30:00 3 0.4 3.8 1.9 3.3 0.4 4.2 2.6 3.4 0.3 4.2 2.6 273 5 277 165 12.4 0 12.7 12.5 06/27/2006 22:40:00 4.2 0.6 5.3 2.3 4.4 0.5 5.3 3 4 0.5 5.3 2.6 286 7 289 165 12.3 0 12.5 12.2 06/27/2006 22:50:00 4.8 0.4 5.7 3.8 5 0.4 6.1 3.8 4.5 0.5 5.7 2.6 292 2 290 165 12.3 0 12.5 12.2 06/27/2006 23:00:00 4.6 0.5 5.7 3.4 4.8 0.4 5.7 3.8 4.2 0.7 5.7 2.6 292 4 287 165 12.1 0 12.5 11.9 06/27/2006 23:10:00 4.3 0.4 5.3 3.4 4.4 0.4 5.3 3.4 3.7 0.5 5.3 2.3 291 4 287 165 12.3 0 12.5 12.2 06/27/2006 23:20:00 4.1 0.4 4.9 3 4.3 0.4 4.9 3 3.4 0.5 4.9 2.3 292 5 290 165 12.2 0 12.5 11.9 06/27/2006 23:30:00 3.7 0.4 4.6 2.3 4 0.4 4.6 2.6 3 0.5 4.2 1.9 293 5 293 165 12.2 0 12.5 11.9 06/27/2006 23:40:00 3.6 0.3 4.2 3 3.8 0.3 4.6 3 3.1 0.5 4.6 2.3 292 6 289 165 12.2 0 12.5 11.9 06/27/2006 23:50:00 3.7 0.3 4.9 3 3.9 0.3 4.9 3 3.2 0.4 4.6 2.3 293 3 293 165 12.3 0 12.5 11.9 06/28/2006 00:00:00 4.4 0.5 5.3 3 4.6 0.5 5.7 3 3.4 0.5 4.9 2.3 296 4 298 165 12 0 12.5 11.7 06/28/2006 00:10:00 5.1 0.3 5.7 3.8 5.2 0.3 6.1 4.2 4.3 0.5 5.7 3 292 4 296 165 11.9 0.1 12.2 11.7 06/28/2006 00:20:00 4.9 0.4 5.7 3.8 5.1 0.4 6.1 4.2 5.1 0.5 6.1 3.4 286 4 285 165 12 0.1 12.2 11.7 06/28/2006 00:30:00 5 0.6 6.8 3.8 5.1 0.6 6.8 3.4 3.9 0.6 5.7 2.6 296 5 295 165 11.9 0.1 12.2 11.4 06/28/2006 00:40:00 5 0.6 6.5 3.8 5.1 0.6 6.8 3.8 4.1 0.7 5.7 2.6 296 6 293 165 11.6 0.2 12.2 11.1 06/28/2006 00:50:00 5.1 0.6 6.5 3.8 5.2 0.6 6.8 3.8 4.1 0.7 6.1 2.6 299 7 289 165 11.8 0.2 12.2 11.4 06/28/2006 01:00:00 5.2 0.5 6.5 3.4 5.3 0.5 6.5 3.8 4.1 0.5 5.3 2.6 294 5 290 165 11.7 0.2 12.2 11.4 06/28/2006 01:10:00 5.2 0.5 6.1 3.8 5.3 0.5 6.5 4.2 4.3 0.7 6.5 2.6 293 4 298 165 11.7 0.3 12.2 11.1 06/28/2006 01:20:00 5.5 0.4 6.5 4.6 5.6 0.4 6.5 4.6 4.6 0.7 6.5 3 293 3 287 165 11.6 0.2 11.9 11.1 06/28/2006 01:30:00 5.5 0.5 6.5 4.6 5.6 0.5 6.5 4.6 5.3 0.5 6.8 3.4 285 5 286 165 11.7 0.3 11.9 11.1 06/28/2006 01:40:00 5.1 0.4 6.1 4.2 5.3 0.4 6.5 4.6 5.2 0.4 6.1 3 282 4 283 165 11.7 0.3 12.2 11.1 06/28/2006 01:50:00 5 0.4 6.1 3.8 5.1 0.4 6.5 3.8 4.9 0.5 6.5 3.4 286 4 281 165 11.7 0.2 11.9 11.4 06/28/2006 02:00:00 4.8 0.4 5.3 3.4 4.9 0.4 5.7 3.8 4.5 0.5 5.7 3 290 4 287 165 11.8 0.1 11.9 11.4 06/28/2006 02:10:00 4.9 0.4 6.1 3.8 5 0.4 6.5 4.2 4.1 0.6 5.7 2.6 292 5 297 165 11.7 0 11.9 11.4 06/28/2006 02:20:00 5.1 0.6 6.8 3.8 5.2 0.6 6.8 3.8 3.8 0.6 5.3 2.6 299 5 296 165 11.7 0 11.9 11.4 06/28/2006 02:30:00 6.1 0.6 7.6 4.6 6.1 0.6 7.6 4.6 4.7 0.7 6.8 2.6 300 7 293 165 11.9 0 12.2 11.7 06/28/2006 02:40:00 5.5 0.7 7.2 4.2 5.5 0.7 7.2 4.2 4.5 0.7 6.5 3 307 6 307 165 11.5 0.2 11.9 11.1 06/28/2006 02:50:00 5.1 0.5 6.1 3.8 5.1 0.5 6.1 3.8 4.3 0.6 5.7 2.6 308 5 307 165 11.3 0.1 11.7 10.9 06/28/2006 03:00:00 4.3 0.4 5.3 3.4 4.3 0.4 5.3 3.4 3.2 0.4 4.6 2.3 305 4 308 165 11.1 0 11.4 10.9 06/28/2006 03:10:00 4.1 0.5 5.3 3 4.2 0.5 5.3 3 3.1 0.5 4.2 1.9 302 4 301 165 11.3 0.1 11.7 11.1 06/28/2006 03:20:00 3.9 0.4 4.9 3 4 0.4 5.3 3 2.9 0.5 4.2 1.9 296 4 300 165 11.3 0.1 11.7 10.9 06/28/2006 03:30:00 3.7 0.3 4.6 3 3.8 0.3 4.6 3 3.3 0.4 4.6 2.3 291 3 291 165 11.3 0 11.7 11.1 06/28/2006 03:40:00 3.8 0.5 4.9 2.6 3.9 0.5 4.9 2.6 3.4 0.4 4.2 2.3 289 5 296 165 11.1 0.2 11.7 10.9 06/28/2006 03:50:00 3.6 0.4 4.6 2.6 3.8 0.4 4.6 3 3.4 0.3 4.2 2.6 290 4 294 165 10.9 0 11.1 10.6 06/28/2006 04:00:00 3.9 0.3 4.9 3.4 4.1 0.3 5.3 3.4 3.9 0.4 4.6 3 281 3 277 165 11 0.1 11.1 10.9 06/28/2006 04:10:00 4.1 0.4 4.9 3.4 4.2 0.4 4.9 3.4 4 0.5 5.3 3 283 5 274 165 11.1 0.1 11.7 10.9 06/28/2006 04:20:00 3.8 0.6 4.9 1.5 4.1 0.4 4.9 3 3.7 0.4 4.6 2.6 279 8 281 165 11.1 0.2 11.4 10.9 06/28/2006 04:30:00 3.4 0.6 4.6 1.9 3.8 0.4 4.6 2.6 3.3 0.5 4.6 1.9 274 6 282 165 11.4 0 11.7 11.1 06/28/2006 04:40:00 3.3 0.6 4.6 1.5 3.8 0.6 4.9 2.3 3.5 0.5 4.6 2.3 271 6 273 165 11.3 0.2 11.7 10.9 06/28/2006 04:50:00 3.6 0.6 4.9 1.9 3.9 0.5 4.9 2.6 3.6 0.4 4.6 2.6 274 5 282 165 11.1 0.1 11.4 10.6 06/28/2006 05:00:00 4.1 0.5 5.3 2.6 4.1 0.5 4.9 2.6 3.9 0.5 5.3 2.6 279 4 280 165 11.1 0 11.4 10.9 06/28/2006 05:10:00 3.7 0.3 4.6 2.6 3.8 0.3 4.6 2.6 3.9 0.3 4.6 3 283 3 284 165 11.4 0.1 11.9 10.9 06/28/2006 05:20:00 4.3 0.4 5.3 3.4 4.3 0.4 5.3 3.4 4.2 0.5 5.3 3 285 4 284 165 11.7 0 11.9 11.4 06/28/2006 05:30:00 4.2 0.4 4.9 3 4.3 0.4 5.3 3 4.1 0.5 4.9 2.6 283 4 279 165 11.8 0 11.9 11.7 06/28/2006 05:40:00 4.7 0.4 5.7 3.4 4.7 0.4 5.7 3.8 4.2 0.5 5.3 2.6 288 3 284 165 11.7 0 11.9 11.1 06/28/2006 05:50:00 4.5 0.3 5.3 3.8 4.6 0.3 5.3 3.8 3.6 0.4 4.6 2.6 294 4 295 165 11.7 0.2 11.9 11.4 06/28/2006 06:00:00 4.3 0.6 6.1 3 4.3 0.6 5.7 3 3.3 0.5 4.6 2.3 296 6 298 165 11.9 0.2 12.5 11.4 06/28/2006 06:10:00 4.4 0.5 5.3 2.6 4.4 0.5 5.3 2.6 3.4 0.6 4.9 1.9 297 6 302 165 12.5 0.2 13 11.9 06/28/2006 06:20:00 4 0.5 5.3 2.6 4.1 0.5 5.3 2.6 3.8 0.5 5.3 2.3 287 4 284 165 12.8 0.1 13.3 12.5 06/28/2006 06:30:00 4 0.5 5.3 2.6 4.2 0.5 5.3 2.6 3.5 0.6 4.6 1.9 291 5 289 165 12.8 0.1 13.3 12.5 06/28/2006 06:40:00 2.6 0.6 3.8 1.1 2.9 0.4 3.8 1.9 2.5 0.5 3.4 1.1 278 8 287 165 12.9 0.1 13 12.2 06/28/2006 06:50:00 1.5 0.5 3 0.4 1.9 0.6 3.4 0.7 1.3 0.8 3 0.4 270 9 274 165 13.2 0.2 13.5 12.7 06/28/2006 07:00:00 0.8 0.4 2.3 0.4 1 0.5 2.6 0.4 0.6 0.3 1.5 0.4 256 9 272 165 13.5 0 13.8 13 06/28/2006 07:10:00 0.5 0.4 2.6 0.4 0.6 0.5 2.6 0.4 0.5 0.4 2.3 0.4 253 27 290 165 13.7 0 13.8 13 06/28/2006 07:20:00 0.9 0.5 1.9 0.4 1.1 0.6 2.6 0.4 0.8 0.4 1.9 0.4 294 23 290 165 13.9 0.1 14.4 13.3 06/28/2006 07:30:00 0.9 0.5 2.3 0.4 1.2 0.8 3 0.4 0.8 0.5 2.3 0.4 259 43 259 165 13.4 0.1 14.1 13 06/28/2006 07:40:00 0.7 0.4 1.9 0.4 0.9 0.6 2.6 0.4 0.6 0.5 2.3 0.4 237 45 282 165 13.7 0.3 14.1 13 06/28/2006 07:50:00 1.1 0.6 2.6 0.4 1.4 0.6 3 0.4 1.3 0.6 3 0.4 193 33 228 165 13.5 0.2 14.1 13 06/28/2006 08:00:00 0.8 0.5 2.3 0.4 1.1 0.6 2.6 0.4 0.9 0.5 2.3 0.4 19 107 160 165 14.4 0.2 14.9 13.8 06/28/2006 08:10:00 0.6 0.4 2.3 0.4 1 0.5 2.3 0.4 0.7 0.4 1.9 0.4 227 51 328 165 14.1 0.2 14.6 13.5 06/28/2006 08:20:00 0.5 0.3 1.5 0.4 0.7 0.5 1.9 0.4 0.6 0.4 1.5 0.4 193 69 312 165 14.4 0.2 14.6 14.1 06/28/2006 08:30:00 0.5 0.4 2.3 0.4 0.7 0.5 2.6 0.4 0.6 0.4 2.3 0.4 197 76 337 165 14.4 0.2 14.9 14.1 06/28/2006 08:40:00 1.1 0.4 2.3 0.4 1.2 0.5 2.3 0.4 1.2 0.5 2.3 0.4 155 22 140 165 14.3 0.1 14.6 14.1 06/28/2006 08:50:00 0.7 0.4 2.3 0.4 0.7 0.4 2.3 0.4 0.8 0.6 2.6 0.4 184 90 165 165 14.7 0.5 15.5 14.1 06/28/2006 09:00:00 0.9 0.4 2.3 0.4 0.8 0.4 1.9 0.4 1.1 0.5 2.6 0.4 169 30 169 165 14.6 0.3 15.5 14.4 06/28/2006 09:10:00 0.9 0.4 2.3 0.4 0.8 0.4 1.9 0.4 1.1 0.6 2.6 0.4 169 28 130 165 14.4 0 14.6 14.1 06/28/2006 09:20:00 0.9 0.6 2.6 0.4 0.9 0.6 2.6 0.4 0.8 0.6 2.3 0.4 188 66 153 165 15 0.2 15.7 14.6 06/28/2006 09:30:00 1.1 0.7 3 0.4 1.1 0.7 3 0.4 1.4 0.6 3 0.4 136 47 145 165 15.1 0.3 15.7 14.6 06/28/2006 09:40:00 1.1 0.6 2.6 0.4 1 0.6 2.6 0.4 0.9 0.6 2.3 0.4 163 69 139 165 15.4 0.2 16 14.9 06/28/2006 09:50:00 0.9 0.5 2.3 0.4 0.9 0.5 2.3 0.4 0.6 0.4 1.9 0.4 317 22 325 165 16.8 0.5 17.4 16 06/28/2006 10:00:00 0.7 0.5 2.3 0.4 0.8 0.5 2.3 0.4 0.6 0.4 1.9 0.4 106 64 80 165 17.2 0 17.7 16.8 06/28/2006 10:10:00 0.9 0.7 3.4 0.4 0.9 0.8 3.4 0.4 0.8 0.6 3 0.4 199 102 98 165 17.5 0 17.7 16.8 06/28/2006 10:20:00 1.5 0.6 3 0.4 1.5 0.6 2.6 0.4 1.6 0.7 3.4 0.4 137 28 145 165 16.4 0.6 17.1 15.7 06/28/2006 10:30:00 2 0.7 3.4 0.4 2 0.7 3.4 0.4 2.2 0.6 3.4 0.7 144 17 137 165 15.7 0 16 15.7 06/28/2006 10:40:00 2.1 0.7 4.2 0.7 2.1 0.7 4.6 0.7 2.5 0.6 4.2 1.1 139 13 138 165 15.7 0 16.3 15.5 06/28/2006 10:50:00 2.4 0.7 4.2 0.7 2.4 0.6 3.8 0.7 2.6 0.5 3.8 1.1 132 14 126 165 15.4 0 15.7 15.2 06/28/2006 11:00:00 1.9 0.6 3.8 0.7 1.9 0.6 3.8 1.1 2.2 0.6 4.2 0.7 132 17 141 165 15.6 0 16 15.5 06/28/2006 11:10:00 1.9 0.5 3.4 0.7 2 0.5 3.4 0.7 2.2 0.5 3.4 1.1 133 14 152 165 15.4 0 15.7 15.2 06/28/2006 11:20:00 2.2 0.5 3.8 0.4 2.3 0.5 4.2 0.4 2.5 0.6 4.2 0.7 128 15 132 165 15.9 0.2 16.3 15.5 06/28/2006 11:30:00 2.1 0.6 3.8 0.4 2.1 0.6 4.2 0.7 2.1 0.6 4.2 0.4 133 16 138 165 16 0 16.3 15.7 06/28/2006 11:40:00 2.3 0.9 4.2 0.4 2.3 0.9 4.2 0.4 2.5 0.7 4.2 0.4 139 18 145 165 16.6 0.3 17.1 16 06/28/2006 11:50:00 2 0.6 3.4 0.7 2.1 0.6 3.4 0.7 2.3 0.6 4.2 0.4 137 17 126 165 16.4 0.2 16.8 16.3 06/28/2006 12:00:00 2.9 0.6 4.6 1.1 3 0.6 4.6 1.5 3.2 0.6 4.9 1.9 138 15 123 165 16.1 0 16.3 16 06/28/2006 12:10:00 2.8 0.5 4.2 1.5 2.8 0.5 4.6 1.5 2.9 0.5 4.2 1.9 138 13 129 165 16 0 16.3 15.7 06/28/2006 12:20:00 3.1 0.5 5.3 1.9 3.2 0.5 4.9 1.5 3.2 0.6 4.9 1.5 138 15 143 165 16.1 0 16.6 15.7 06/28/2006 12:30:00 2.6 0.6 4.6 0.7 2.7 0.6 4.9 1.1 2.9 0.6 4.2 1.5 136 13 122 165 16.3 0.2 16.8 15.7 06/28/2006 12:40:00 2.6 0.5 4.6 1.5 2.7 0.5 4.9 1.5 2.9 0.6 4.2 1.1 132 13 126 165 16.6 0 16.8 16.3 06/28/2006 12:50:00 2.7 0.7 4.6 1.1 2.9 0.6 4.6 1.5 3 0.6 4.6 1.5 131 14 142 165 16.6 0.1 16.8 16.3 06/28/2006 13:00:00 2.7 0.6 4.6 0.7 2.9 0.6 4.6 1.1 3 0.7 4.6 1.1 133 10 152 165 16.6 0.2 16.8 16.3 06/28/2006 13:10:00 2.9 0.6 4.6 1.5 3 0.5 4.6 1.5 3.1 0.6 4.9 1.9 131 12 118 165 17 0.1 17.7 16.8 06/28/2006 13:20:00 3.4 0.7 5.7 1.9 3.5 0.7 5.7 1.9 3.7 0.6 5.7 2.3 128 13 119 165 17 0.2 17.7 16.6 06/28/2006 13:30:00 3.4 0.5 5.3 1.9 3.5 0.5 5.3 2.3 3.6 0.5 5.3 2.3 122 9 135 165 16.6 0.1 16.8 16.6 06/28/2006 13:40:00 3.3 0.6 4.9 1.5 3.4 0.6 4.9 1.9 3.6 0.5 5.3 1.9 128 11 123 165 16.8 0 17.1 16.8 06/28/2006 13:50:00 3.3 0.5 4.9 1.9 3.4 0.5 4.9 2.3 3.4 0.6 5.3 1.9 129 10 116 165 16.8 0 16.8 16.6 06/28/2006 14:00:00 3.3 0.6 4.9 1.5 3.5 0.6 5.3 2.3 3.4 0.6 4.9 1.9 120 9 132 165 16.8 0 17.1 16.6 06/28/2006 14:10:00 3.3 0.7 4.9 1.5 3.4 0.7 5.3 1.5 3.6 0.7 5.3 1.5 128 12 128 165 17.3 0.1 18 16.8 06/28/2006 14:20:00 3.1 0.7 4.9 1.1 3.3 0.7 5.3 1.1 3.3 0.7 5.3 1.5 129 13 138 165 17.3 0.1 17.7 17.1 06/28/2006 14:30:00 3.3 0.6 4.9 2.3 3.4 0.6 4.9 1.9 3.5 0.6 5.3 2.3 126 13 111 165 17 0 17.4 16.8 06/28/2006 14:40:00 3.3 0.6 4.6 1.5 3.4 0.7 4.9 1.5 3.4 0.6 5.3 1.9 141 15 121 165 17.5 0.2 18 16.8 06/28/2006 14:50:00 2.7 0.6 3.8 1.5 2.8 0.6 4.2 1.5 2.9 0.6 4.6 1.5 142 18 116 165 17.1 0.1 17.4 16.8 06/28/2006 15:00:00 3.4 0.6 4.9 1.9 3.5 0.6 5.3 1.5 3.5 0.6 4.9 2.3 130 13 124 165 17.3 0.2 17.4 16.8 06/28/2006 15:10:00 3.5 0.6 5.7 1.9 3.6 0.6 5.7 2.3 3.7 0.6 5.7 2.6 127 12 124 165 17.7 0 18 17.1 06/28/2006 15:20:00 3.2 0.6 4.9 1.5 3.3 0.6 4.9 1.9 3.4 0.5 4.9 2.3 127 9 131 165 17.3 0 17.7 17.1 06/28/2006 15:30:00 2.9 0.7 4.6 1.1 3.1 0.7 4.9 1.5 3.3 0.5 4.6 1.9 130 11 126 165 17.3 0 17.7 16.8 06/28/2006 15:40:00 2.5 0.6 4.2 1.1 2.8 0.6 4.6 1.5 2.9 0.5 4.6 1.5 128 11 116 165 17.6 0 18 17.4 06/28/2006 15:50:00 2.3 0.7 4.2 0.7 2.5 0.6 4.6 1.1 2.8 0.6 4.6 1.5 136 12 135 165 17.5 0 17.7 17.4 06/28/2006 16:00:00 2.4 0.6 4.2 1.1 2.6 0.6 4.2 1.1 2.8 0.6 4.2 1.5 144 11 136 165 17.2 0.1 17.7 16.8 06/28/2006 16:10:00 1.8 0.6 3.4 0.4 2.1 0.6 3.8 0.4 2.4 0.4 3.4 1.5 149 15 154 165 17 0 17.1 16.8 06/28/2006 16:20:00 2.5 0.5 3.8 1.5 2.7 0.5 4.2 1.5 2.9 0.4 4.6 1.9 121 10 129 165 16.7 0 17.1 16.6 06/28/2006 16:30:00 2.1 0.6 3.8 0.4 2.4 0.5 3.8 1.1 2.4 0.6 3.8 0.7 124 13 111 165 16.8 0 17.1 16.6 06/28/2006 16:40:00 1.9 0.7 3.4 0.4 2.2 0.6 3.4 0.7 2.3 0.5 3.4 1.1 135 17 111 165 17.2 0.2 17.7 16.6 06/28/2006 16:50:00 2.1 0.5 3.4 0.7 2.5 0.4 3.8 1.5 2.6 0.4 3.8 1.9 136 12 110 165 17.4 0.1 17.7 17.1 06/28/2006 17:00:00 2.1 0.6 3.8 0.7 2.5 0.5 4.2 1.1 2.5 0.5 3.8 1.1 127 13 143 165 17.3 0 17.4 17.1 06/28/2006 17:10:00 2.4 0.6 3.8 0.7 2.7 0.5 4.2 1.1 2.8 0.4 3.8 1.5 121 13 110 165 17.3 0.1 17.4 16.8 06/28/2006 17:20:00 2.7 0.4 4.2 1.5 2.9 0.4 3.8 1.9 2.9 0.5 4.6 1.9 130 11 139 165 17.3 0 17.7 17.1 06/28/2006 17:30:00 2 0.7 3.4 0.4 2.4 0.6 3.8 0.7 2.5 0.5 4.2 1.1 128 13 125 165 17.5 0 17.7 17.4 06/28/2006 17:40:00 1.4 0.6 3 0.4 1.9 0.5 3.4 0.4 2 0.6 3.4 0.4 130 21 140 165 17.8 0.1 18 17.4 06/28/2006 17:50:00 0.8 0.5 2.3 0.4 1.1 0.7 2.6 0.4 1.2 0.7 3 0.4 131 27 164 165 17.5 0.2 18 17.4 06/28/2006 18:00:00 0.5 0.2 1.5 0.4 0.9 0.4 1.9 0.4 1 0.5 2.3 0.4 178 27 165 165 17.5 0.1 17.7 17.1 06/28/2006 18:10:00 0.4 0.2 1.5 0.4 0.6 0.4 1.9 0.4 0.7 0.4 1.9 0.4 147 15 165 165 17.5 0 17.7 17.1 06/28/2006 18:20:00 0.4 0.2 1.1 0.4 0.6 0.4 1.9 0.4 0.6 0.4 1.9 0.4 116 61 127 165 17.6 0 17.7 17.4 06/28/2006 18:30:00 0.9 0.8 3.8 0.4 1 0.8 3.8 0.4 0.8 0.7 3.4 0.4 91 51 29 165 17.5 0.1 17.7 17.1 06/28/2006 18:40:00 0.4 0.2 1.5 0.4 0.5 0.4 2.3 0.4 0.5 0.3 2.6 0.4 140 69 115 165 17.6 0 18 17.4 06/28/2006 18:50:00 0.5 0.4 1.5 0.4 0.6 0.4 1.9 0.4 0.6 0.4 1.9 0.4 208 69 332 165 17.8 0.3 18.2 17.4 06/28/2006 19:00:00 0.8 0.4 1.9 0.4 0.8 0.5 1.9 0.4 0.8 0.4 1.5 0.4 344 18 333 165 16.6 0.4 18 16.3 06/28/2006 19:10:00 1.1 0.7 2.6 0.4 1.3 0.7 2.6 0.4 1.3 0.7 2.6 0.4 282 41 245 165 15.6 0.4 16.3 14.9 06/28/2006 19:20:00 0.8 0.5 1.9 0.4 1 0.6 1.9 0.4 1 0.6 2.3 0.4 265 12 242 165 14.9 0 15.2 14.6 06/28/2006 19:30:00 1.6 0.5 2.3 0.4 1.7 0.4 2.6 0.7 1.6 0.5 2.6 0.4 302 17 321 165 15 0.2 15.2 14.4 06/28/2006 19:40:00 1.8 0.3 2.6 1.1 1.9 0.3 2.6 1.1 1.5 0.3 2.3 0.7 293 11 281 165 14.6 0 14.9 14.1 06/28/2006 19:50:00 1.4 0.5 3 0.4 1.5 0.5 3 0.7 1.3 0.5 2.6 0.4 318 10 296 165 14.8 0 15.2 14.6 06/28/2006 20:00:00 2.8 0.4 3.4 1.5 2.9 0.3 3.4 1.9 2.1 0.4 3 1.1 298 5 300 165 15.1 0 15.2 15.2 06/28/2006 20:10:00 3.1 0.3 3.8 2.3 3.3 0.3 4.2 2.6 2.5 0.4 3.4 1.9 301 4 298 165 15 0 15.2 14.9 06/28/2006 20:20:00 3.3 0.4 4.2 2.3 3.4 0.4 4.6 2.3 3 0.4 4.6 2.3 306 7 332 165 15.5 0.2 16 15.2 06/28/2006 20:30:00 3.2 0.5 4.6 1.9 3.2 0.5 4.6 2.3 2.9 0.5 4.6 1.9 304 12 293 165 15.7 0 16 15.2 06/28/2006 20:40:00 3.5 0.4 4.9 2.6 3.6 0.4 4.9 2.6 2.9 0.5 4.2 1.9 298 6 289 165 15.5 0 15.7 15.2 06/28/2006 20:50:00 3.7 0.6 5.3 2.3 3.7 0.5 5.3 2.6 3.1 0.6 4.9 1.5 299 7 297 165 15.2 0 15.5 15.2 06/28/2006 21:00:00 4.1 0.4 5.3 3 4.2 0.4 5.3 3 3.4 0.5 4.6 1.9 299 6 307 165 14.7 0.1 15.2 14.6 06/28/2006 21:10:00 4.1 0.6 5.7 2.6 4.3 0.6 5.7 3 3.4 0.7 5.3 1.9 295 5 293 165 14.6 0 14.9 14.4 06/28/2006 21:20:00 3.6 0.4 4.9 2.3 3.8 0.4 4.9 3 3.2 0.5 4.6 2.3 292 5 300 165 13.9 0.2 14.6 13.3 06/28/2006 21:30:00 3.7 0.3 4.6 2.6 3.9 0.3 4.6 3 3.7 0.4 4.9 2.6 283 3 284 165 13.5 0.2 13.8 13 06/28/2006 21:40:00 3.5 0.4 4.2 2.6 3.8 0.4 4.6 3 3.7 0.3 4.6 3 281 6 273 165 13.4 0 13.5 13 06/28/2006 21:50:00 3.5 0.4 4.9 2.3 3.8 0.4 4.9 3 3.6 0.4 4.6 2.6 282 5 278 165 13.3 0 13.5 12.7 06/28/2006 22:00:00 3.7 0.4 4.6 3 3.9 0.4 4.9 3 3.4 0.4 4.6 1.9 289 6 296 165 13.2 0 13.5 12.5 06/28/2006 22:10:00 3.6 0.5 4.6 2.3 3.8 0.5 4.9 2.6 3.2 0.5 4.6 1.5 292 4 293 165 13.1 0 13.5 12.5 06/28/2006 22:20:00 3.2 0.4 4.2 2.3 3.4 0.4 4.2 2.6 2.8 0.4 3.4 1.5 293 6 288 165 13 0.1 13.3 12.7 06/28/2006 22:30:00 3.1 0.4 4.2 2.3 3.4 0.4 4.6 2.6 3 0.5 4.6 1.9 288 6 293 165 13 0 13.3 12.7 06/28/2006 22:40:00 3 0.4 3.8 1.9 3.3 0.3 4.2 2.3 3.1 0.4 3.8 2.3 279 4 283 165 13 0 13.3 12.7 06/28/2006 22:50:00 3 0.7 4.9 1.5 3.4 0.6 5.3 1.9 3.3 0.6 5.3 1.9 275 9 284 165 13.1 0 13.3 12.7 06/28/2006 23:00:00 3.5 0.5 4.9 2.3 3.8 0.5 4.9 3 3.7 0.5 4.9 2.6 278 5 277 165 13 0 13.3 12.7 06/28/2006 23:10:00 3.5 0.5 4.6 2.3 3.7 0.5 4.6 2.6 3.6 0.5 4.6 2.6 281 5 287 165 13 0 13 12.7 06/28/2006 23:20:00 3.8 0.6 4.6 2.3 4 0.5 4.9 2.3 3.8 0.7 4.9 1.9 282 4 283 165 12.9 0 13 12.7 06/28/2006 23:30:00 4.4 0.4 5.3 2.6 4.5 0.4 5.3 3 4.2 0.4 5.3 3 286 3 285 165 12.8 0 13 12.7 06/28/2006 23:40:00 3.1 0.4 4.2 1.9 3.3 0.4 4.6 2.3 2.5 0.5 4.2 1.5 293 4 292 165 12.7 0 13 12.7 06/28/2006 23:50:00 2.9 0.4 3.8 1.5 3.5 0.4 4.2 2.3 3.3 0.4 4.2 1.9 270 13 282 165 12.7 0 13 12.5 06/29/2006 00:00:00 2.7 0.4 3.8 1.9 3.8 0.3 4.6 3.4 3.7 0.3 4.2 2.6 264 4 265 165 12.5 0 12.7 12.5 06/29/2006 00:10:00 2.3 0.5 3.4 1.1 3.3 0.2 3.8 2.6 3.2 0.2 3.8 2.6 262 4 267 165 12.4 0 12.5 12.2 06/29/2006 00:20:00 2.5 0.3 3 1.5 2.9 0.2 3.4 2.3 2.8 0.2 3.4 2.3 244 7 253 165 12.3 0 12.5 12.2 06/29/2006 00:30:00 1.7 0.3 2.6 1.1 2 0.3 2.6 1.5 2.2 0.2 3 1.9 238 3 238 165 12.3 0 12.5 11.9 06/29/2006 00:40:00 1 0.4 1.9 0.4 1.2 0.4 2.3 0.4 1.6 0.3 2.6 1.1 211 9 231 165 12.5 0 12.7 12.2 06/29/2006 00:50:00 0.7 0.2 1.1 0.4 0.9 0.3 1.5 0.4 1.2 0.3 1.5 0.4 204 0 205 165 12.6 0 12.7 12.5 06/29/2006 01:00:00 1 0.3 1.5 0.4 1.2 0.3 1.9 0.4 1.4 0.2 1.9 0.4 203 1 204 165 12.6 0 12.7 12.5 06/29/2006 01:10:00 0.5 0.2 1.1 0.4 0.4 0.1 1.1 0.4 1.1 0.2 1.5 0.7 201 2 202 165 12.2 0.2 12.7 11.9 06/29/2006 01:20:00 0.6 0.3 1.5 0.4 0.8 0.3 1.5 0.4 1.1 0.2 1.9 0.7 172 6 187 165 11.9 0 12.2 11.7 06/29/2006 01:30:00 1.4 0.4 2.3 0.7 1.6 0.4 2.3 0.7 1.8 0.3 2.3 1.1 164 6 164 165 11.8 0.1 12.2 11.4 06/29/2006 01:40:00 1.4 0.3 1.9 0.7 1.6 0.2 2.3 1.1 1.9 0.2 2.3 1.5 163 1 162 165 11.5 0.1 11.9 11.1 06/29/2006 01:50:00 1.6 0.2 2.3 1.1 1.7 0.2 2.3 1.1 2.1 0.2 2.6 1.5 164 1 165 165 11.2 0.2 11.7 10.9 06/29/2006 02:00:00 1.7 0.2 2.3 1.1 1.7 0.2 2.3 1.1 1.9 0.2 2.3 1.5 171 4 173 165 11.3 0.1 11.7 10.9 06/29/2006 02:10:00 1.1 0.4 1.9 0.7 1.2 0.3 1.9 0.7 1.5 0.3 2.3 0.7 166 1 165 165 11.3 0.1 11.7 10.9 06/29/2006 02:20:00 0.4 0.1 1.1 0.4 0.4 0.2 1.1 0.4 1 0.3 1.9 0.4 165 0 165 165 11.6 0.2 11.9 11.1 06/29/2006 02:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 1 0.3 1.5 0.4 162 2 165 165 11.7 0.2 11.9 11.1 06/29/2006 02:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.5 0.2 1.1 0.4 160 0 165 165 11.5 0 11.9 11.1 06/29/2006 02:50:00 0.5 0.3 1.1 0.4 0.4 0 0.4 0.4 0.9 0.4 1.5 0.4 160 1 161 165 11.3 0.1 11.7 10.9 06/29/2006 03:00:00 0.4 0.2 1.1 0.4 0.4 0 0.4 0.4 0.5 0.3 1.5 0.4 151 1 155 165 11.3 0 11.4 10.9 06/29/2006 03:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 150 0 165 165 11.3 0 11.4 11.1 06/29/2006 03:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 150 0 165 165 11.4 0 11.7 11.4 06/29/2006 03:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 151 0 165 165 11.3 0.1 11.7 10.9 06/29/2006 03:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 151 0 165 165 11.2 0 11.4 10.9 06/29/2006 03:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 151 0 165 165 11.2 0.1 11.7 10.9 06/29/2006 04:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.6 0.3 1.1 0.4 150 0 165 165 11.2 0.1 11.4 10.9 06/29/2006 04:10:00 0.5 0.3 1.5 0.4 0.5 0.4 1.5 0.4 0.9 0.3 1.5 0.4 145 2 145 165 11 0.1 11.4 10.9 06/29/2006 04:20:00 1.4 0.3 2.3 0.7 1.5 0.3 2.3 1.1 1.6 0.3 2.3 1.1 135 9 124 165 10.9 0.1 11.1 10.6 06/29/2006 04:30:00 0.5 0.2 1.5 0.4 0.6 0.4 1.9 0.4 1 0.4 1.9 0.4 124 0 124 165 10.9 0 11.1 10.6 06/29/2006 04:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0.2 1.1 0.4 124 0 165 165 11.1 0.1 11.7 10.6 06/29/2006 04:50:00 0.4 0.2 1.1 0.4 0.4 0.2 1.5 0.4 0.5 0.3 1.5 0.4 133 8 124 165 11.6 0.1 11.9 11.1 06/29/2006 05:00:00 1.1 0.6 2.3 0.4 1.1 0.7 2.3 0.4 1.2 0.5 2.3 0.4 155 7 164 165 11.8 0 11.9 11.7 06/29/2006 05:10:00 1.7 0.6 2.6 0.4 1.6 0.6 2.6 0.4 1.6 0.5 2.6 0.4 164 5 164 165 12.1 0.1 12.5 11.7 06/29/2006 05:20:00 1.1 0.5 2.3 0.4 1.1 0.6 2.3 0.4 1.2 0.5 2.3 0.4 164 4 165 165 12.3 0.2 12.7 11.9 06/29/2006 05:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 156 1 165 165 12.7 0.2 13 12.2 06/29/2006 05:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 157 0 165 165 13.1 0 13.3 13 06/29/2006 05:50:00 0.4 0 0.7 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 173 28 228 165 13.4 0.1 13.8 13 06/29/2006 06:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 229 0 165 165 13.7 0 13.8 13.5 06/29/2006 06:10:00 0.4 0.1 0.7 0.4 0.4 0 0.4 0.4 0.4 0.1 1.1 0.4 229 0 229 165 14.2 0.2 14.6 13.8 06/29/2006 06:20:00 0.5 0.2 1.1 0.4 0.4 0.1 1.1 0.4 0.6 0.3 1.5 0.4 294 22 297 165 14.6 0.1 14.9 14.1 06/29/2006 06:30:00 0.4 0.1 0.7 0.4 0.4 0 0.4 0.4 0.4 0.1 1.1 0.4 314 0 314 165 14.6 0.2 15.2 14.1 06/29/2006 06:40:00 0.4 0 0.7 0.4 0.4 0 0.4 0.4 0.4 0.1 1.1 0.4 249 66 179 165 14.6 0.5 15.5 13.5 06/29/2006 06:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.5 0.3 1.5 0.4 179 0 165 165 13.5 0.1 13.8 13 06/29/2006 07:00:00 0.4 0.1 1.1 0.4 0.4 0.1 1.1 0.4 0.6 0.4 1.5 0.4 169 8 164 165 13.1 0.1 13.8 12.5 06/29/2006 07:10:00 0.4 0.2 1.1 0.4 0.5 0.3 1.5 0.4 0.5 0.3 1.9 0.4 156 16 143 165 13.9 0 14.4 13.5 06/29/2006 07:20:00 0.4 0.1 0.7 0.4 0.4 0.1 1.1 0.4 0.4 0.1 1.1 0.4 7 79 298 165 14.7 0.5 15.5 13.8 06/29/2006 07:30:00 0.4 0.2 1.5 0.4 0.4 0.3 1.5 0.4 0.5 0.3 1.5 0.4 150 32 146 165 14.7 0.2 15.5 14.6 06/29/2006 07:40:00 0.4 0.2 1.1 0.4 0.4 0.2 1.1 0.4 0.4 0.2 1.5 0.4 141 12 116 165 15.2 0.1 15.5 14.9 06/29/2006 07:50:00 1.3 0.5 2.6 0.4 1.4 0.5 2.6 0.4 1.7 0.5 2.6 0.4 144 18 127 165 14.7 0.2 15.5 14.4 06/29/2006 08:00:00 1.3 0.5 2.3 0.4 1.3 0.4 2.6 0.4 1.5 0.4 2.3 0.4 148 22 148 165 14.5 0 14.9 14.4 06/29/2006 08:10:00 1.1 0.5 2.3 0.4 1.2 0.5 2.3 0.4 1.4 0.5 2.6 0.4 153 21 137 165 14.5 0.1 14.9 13.8 06/29/2006 08:20:00 1.1 0.5 2.3 0.4 1.2 0.4 2.6 0.4 1.4 0.5 2.3 0.4 140 17 135 165 14.8 0 15.2 14.6 06/29/2006 08:30:00 1.5 0.5 3 0.4 1.6 0.4 3 0.7 1.8 0.5 3.4 0.7 149 15 161 165 15 0.1 15.2 14.6 06/29/2006 08:40:00 1.8 0.4 3 0.7 1.9 0.4 3 1.1 1.9 0.3 3 1.1 148 15 140 165 14.7 0 14.9 14.6 06/29/2006 08:50:00 2 0.3 3 1.1 2.1 0.3 3.4 1.1 2 0.3 3 1.1 156 8 151 165 14.6 0 14.9 14.6 06/29/2006 09:00:00 1.9 0.4 3 1.1 2.1 0.4 3 1.5 2.2 0.4 3.4 1.1 145 8 154 165 15.2 0.1 15.5 14.9 06/29/2006 09:10:00 2.1 0.4 3.4 1.1 2.4 0.4 4.6 1.5 2.4 0.5 3.8 1.1 157 9 169 165 15 0 15.5 14.9 06/29/2006 09:20:00 2.3 0.5 3.8 1.1 2.5 0.5 3.8 1.5 2.6 0.5 3.8 1.5 150 9 128 165 15 0.1 15.5 14.6 06/29/2006 09:30:00 2.3 0.6 4.6 0.7 2.5 0.5 4.6 1.5 2.6 0.5 4.6 1.5 148 13 144 165 15.3 0 15.7 15.2 06/29/2006 09:40:00 2.7 0.5 3.8 1.5 2.8 0.5 4.2 1.9 2.9 0.5 4.2 1.5 156 9 151 165 15.5 0 15.7 15.2 06/29/2006 09:50:00 2.9 0.4 4.2 1.9 3 0.4 4.6 1.9 3 0.4 4.2 1.9 159 8 156 165 15.1 0.2 15.7 14.6 06/29/2006 10:00:00 2.6 0.5 3.4 1.5 2.7 0.4 3.4 1.5 2.8 0.4 3.8 1.5 156 9 163 165 15 0 15.5 14.9 06/29/2006 10:10:00 1.9 0.7 3.8 0.4 2.2 0.6 3.8 0.7 2.2 0.5 3.4 1.1 155 12 155 165 15.1 0 15.5 14.9 06/29/2006 10:20:00 1.2 0.6 2.6 0.4 1.5 0.6 2.6 0.4 1.6 0.6 3 0.4 148 17 163 165 15 0 15.5 14.9 06/29/2006 10:30:00 0.7 0.5 2.3 0.4 1.1 0.5 2.3 0.4 1.2 0.5 2.6 0.4 151 13 162 165 15.3 0 15.7 15.2 06/29/2006 10:40:00 0.6 0.4 1.9 0.4 0.9 0.5 2.3 0.4 1 0.5 2.3 0.4 151 15 128 165 15.5 0 16 15.2 06/29/2006 10:50:00 0.6 0.4 1.9 0.4 1 0.5 2.3 0.4 1.1 0.6 2.6 0.4 160 7 154 165 15.6 0 16 15.5 06/29/2006 11:00:00 0.5 0.3 2.3 0.4 0.7 0.4 2.3 0.4 0.9 0.5 2.3 0.4 182 18 173 165 15.7 0.1 16.3 15.5 06/29/2006 11:10:00 0.4 0.2 1.5 0.4 0.5 0.3 1.9 0.4 0.6 0.4 1.9 0.4 167 45 91 165 16.3 0 16.6 16 06/29/2006 11:20:00 0.6 0.4 2.3 0.4 0.7 0.5 2.3 0.4 0.9 0.6 3 0.4 156 43 130 165 16.5 0 16.8 16.3 06/29/2006 11:30:00 0.9 0.6 2.3 0.4 0.9 0.6 2.3 0.4 1.1 0.6 2.6 0.4 130 22 133 165 16.5 0.1 16.8 16.3 06/29/2006 11:40:00 0.9 0.5 2.6 0.4 0.8 0.5 2.6 0.4 0.9 0.5 2.6 0.4 357 102 118 165 17.1 0.1 17.4 16.8 06/29/2006 11:50:00 0.7 0.5 2.6 0.4 0.6 0.5 2.3 0.4 0.6 0.4 1.9 0.4 354 64 15 165 17.5 0 18 17.1 06/29/2006 12:00:00 1.7 0.7 3.4 0.4 1.7 0.8 3.4 0.4 1.9 0.7 3.4 0.4 125 28 116 165 17.2 0.4 18 16.8 06/29/2006 12:10:00 1.6 0.6 3 0.4 1.5 0.7 2.6 0.4 1.8 0.5 3 0.4 125 15 135 165 16.4 0.1 16.8 16.3 06/29/2006 12:20:00 1.5 0.7 3.4 0.4 1.5 0.7 3.4 0.4 1.6 0.7 3.4 0.4 118 30 114 165 16.7 0.1 16.8 16.3 06/29/2006 12:30:00 1.5 0.6 3 0.4 1.5 0.6 3 0.4 1.6 0.5 2.6 0.4 90 22 111 165 16.6 0 16.8 16.6 06/29/2006 12:40:00 1.6 0.6 3.4 0.4 1.5 0.6 3 0.4 1.7 0.5 3 0.4 110 15 102 165 17 0 17.1 16.8 06/29/2006 12:50:00 1.5 0.6 3 0.4 1.5 0.7 3 0.4 1.6 0.6 2.6 0.4 116 29 129 165 17.1 0.1 17.4 16.8 06/29/2006 13:00:00 1.3 0.5 2.6 0.4 1.2 0.5 2.6 0.4 1.6 0.4 3 0.7 126 11 150 165 15.9 0.4 16.8 15.5 06/29/2006 13:10:00 2 0.5 3.4 1.1 2 0.5 3.4 0.7 2.1 0.6 3.8 0.7 111 11 100 165 15.6 0 16 15.2 06/29/2006 13:20:00 2.6 0.4 4.2 1.9 2.7 0.4 4.2 1.9 2.7 0.5 3.8 1.5 118 11 132 165 15.7 0 16.3 15.5 06/29/2006 13:30:00 2.8 0.6 4.2 1.1 2.9 0.5 4.2 1.5 2.8 0.6 4.2 1.1 124 12 134 165 15.5 0 15.7 15.5 06/29/2006 13:40:00 3 0.8 4.9 1.1 3.2 0.8 4.9 1.1 3.2 0.7 4.6 1.5 130 11 128 165 15.5 0 15.7 15.2 06/29/2006 13:50:00 3.2 0.5 4.6 1.9 3.4 0.5 4.9 2.3 3.3 0.6 4.9 1.9 125 9 148 165 15.2 0.1 15.5 14.9 06/29/2006 14:00:00 3.1 0.5 4.2 1.9 3.3 0.5 4.6 1.9 3.3 0.4 4.6 1.9 125 8 115 165 14.8 0.1 15.2 14.6 06/29/2006 14:10:00 2.4 0.5 3.4 1.1 2.6 0.4 3.4 1.5 2.5 0.4 3.4 1.5 117 10 126 165 14.5 0 14.6 14.4 06/29/2006 14:20:00 1.5 0.5 2.3 0.4 1.7 0.5 2.6 0.4 1.6 0.5 3 0.4 85 17 105 165 14.3 0 14.6 13.8 06/29/2006 14:30:00 2.2 0.6 3.4 0.4 2.4 0.6 3.4 0.4 2.3 0.6 3.4 0.4 45 17 27 165 14.5 0 14.6 13.8 06/29/2006 14:40:00 2.7 0.4 3.8 1.5 2.9 0.4 3.8 1.9 2.9 0.4 3.8 1.9 34 8 35 165 14.4 0 14.6 14.4 06/29/2006 14:50:00 2.9 0.3 3.4 1.9 3.1 0.3 3.8 1.9 3.1 0.4 3.8 1.9 34 7 43 165 14.1 0 14.6 14.1 06/29/2006 15:00:00 1.8 0.8 3 0.4 1.8 1 3.4 0.4 2.1 0.8 3.4 0.4 17 15 29 165 14.2 0 14.6 14.1 06/29/2006 15:10:00 1.1 0.4 1.9 0.4 1 0.5 1.9 0.4 1.4 0.4 2.6 0.4 16 11 5 165 14.4 0 14.6 14.4 06/29/2006 15:20:00 1.7 0.7 3 0.4 1.7 0.8 3 0.4 2 0.7 3 0.4 336 18 9 165 14.4 0 14.6 14.4 06/29/2006 15:30:00 2.2 0.4 3.4 1.1 2.1 0.6 3.4 0.7 2.6 0.3 3.4 1.5 349 12 348 165 14.5 0 14.6 14.4 06/29/2006 15:40:00 2 0.4 2.6 1.1 1.7 0.5 2.6 0.4 2.4 0.4 3.4 1.5 360 12 353 165 14.4 0 14.6 14.4 06/29/2006 15:50:00 1.6 0.4 2.6 0.4 1.5 0.5 2.6 0.4 2.1 0.3 2.6 1.5 350 9 336 165 14.4 0 14.6 14.4 06/29/2006 16:00:00 0.9 0.6 3.4 0.4 0.9 0.6 3.4 0.4 1.1 0.6 2.3 0.4 330 36 304 165 14.4 0 14.9 14.1 06/29/2006 16:10:00 0.5 0.3 1.5 0.4 0.5 0.3 1.5 0.4 0.7 0.4 1.9 0.4 307 35 339 165 14.6 0 14.9 14.4 06/29/2006 16:20:00 0.6 0.4 1.9 0.4 0.5 0.3 1.5 0.4 1 0.5 2.6 0.4 2 17 357 165 14.9 0 15.2 14.9 06/29/2006 16:30:00 1.2 0.9 3.4 0.4 1.3 1 3.8 0.4 1.5 0.9 3.4 0.4 103 58 85 165 14.5 0.2 14.9 14.1 06/29/2006 16:40:00 2.2 0.5 3 0.4 2.3 0.5 3.4 0.4 2.4 0.5 3.4 1.1 102 13 93 165 13.7 0.1 14.1 13.3 06/29/2006 16:50:00 1 0.7 3 0.4 1.2 0.7 3 0.4 1.5 0.6 3 0.4 108 15 112 165 13.5 0 13.8 13 06/29/2006 17:00:00 0.5 0.3 1.9 0.4 0.7 0.4 1.9 0.4 1.1 0.4 1.9 0.4 30 64 325 165 13.7 0 13.8 13.3 06/29/2006 17:10:00 0.7 0.4 1.9 0.4 1 0.5 1.9 0.4 1.4 0.4 2.3 0.4 334 13 341 165 13.5 0.1 14.1 13 06/29/2006 17:20:00 1.2 0.6 2.6 0.4 1.3 0.7 3 0.4 1.7 0.6 2.6 0.4 349 14 329 165 13.3 0.2 13.5 12.7 06/29/2006 17:30:00 1.1 0.5 2.3 0.4 1.1 0.5 2.6 0.4 1.4 0.5 2.6 0.4 17 26 7 165 13.5 0.1 13.8 13 06/29/2006 17:40:00 1 0.5 2.3 0.4 1.2 0.5 2.3 0.4 1.4 0.4 2.6 0.7 35 21 55 165 13.5 0.1 13.8 13 06/29/2006 17:50:00 0.7 0.4 2.3 0.4 0.8 0.5 2.6 0.4 0.9 0.6 2.6 0.4 45 35 16 165 13.5 0 13.8 13.3 06/29/2006 18:00:00 0.6 0.4 1.9 0.4 0.6 0.4 1.9 0.4 1.1 0.5 2.3 0.4 9 17 4 165 13.7 0 13.8 13.5 06/29/2006 18:10:00 1.2 0.4 1.9 0.4 0.8 0.4 1.5 0.4 1.8 0.3 2.3 1.1 357 7 352 165 13.5 0.1 13.8 13 06/29/2006 18:20:00 1.6 0.3 2.3 0.7 1.4 0.6 2.6 0.4 2 0.3 2.6 1.5 12 14 15 165 13.3 0 13.5 13 06/29/2006 18:30:00 1.7 0.3 2.6 1.1 1.2 0.5 2.6 0.4 2 0.3 2.6 1.1 2 11 18 165 13.3 0 13.5 12.7 06/29/2006 18:40:00 1.6 0.4 2.6 0.4 1.6 0.6 3 0.4 2.1 0.4 3 1.1 355 18 336 165 13.3 0 13.5 12.7 06/29/2006 18:50:00 1.4 0.4 2.3 0.4 1.2 0.4 2.3 0.4 1.8 0.3 2.6 1.1 11 12 3 165 13.3 0.1 13.5 13 06/29/2006 19:00:00 0.7 0.4 1.5 0.4 0.9 0.5 1.9 0.4 1.2 0.4 2.3 0.4 341 21 343 165 13.3 0.3 13.5 12.5 06/29/2006 19:10:00 0.5 0.3 1.9 0.4 0.5 0.3 1.9 0.4 1.1 0.6 2.3 0.4 343 19 46 165 12.9 0.2 13.3 12.2 06/29/2006 19:20:00 0.9 0.4 1.9 0.4 0.9 0.4 2.3 0.4 1.4 0.4 2.3 0.4 2 17 339 165 13.1 0 13.3 12.5 06/29/2006 19:30:00 0.9 0.5 2.3 0.4 1 0.5 2.3 0.4 1.6 0.4 2.6 0.4 351 14 355 165 12.9 0.1 13.3 12.5 06/29/2006 19:40:00 0.4 0.2 1.1 0.4 0.5 0.3 1.5 0.4 0.8 0.5 2.3 0.4 353 112 46 165 12.8 0 13 12.7 06/29/2006 19:50:00 2 0.7 3.4 0.4 2.3 0.6 3.4 0.4 2.3 0.6 3.4 0.7 108 12 94 165 12.4 0.3 13 11.9 06/29/2006 20:00:00 1.2 0.8 3 0.4 1.6 0.8 3 0.4 1.8 0.5 3.4 0.7 85 24 94 165 11.8 0 11.9 11.7 06/29/2006 20:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.5 0.2 1.1 0.4 44 10 165 165 12.1 0 12.5 11.7 06/29/2006 20:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0.2 1.1 0.4 297 12 165 165 12.4 0 12.5 12.2 06/29/2006 20:30:00 0.4 0.2 1.5 0.4 0.6 0.4 1.9 0.4 0.5 0.4 1.9 0.4 297 38 225 165 12.4 0 12.5 12.2 06/29/2006 20:40:00 0.4 0.2 1.5 0.4 0.6 0.3 1.9 0.4 0.5 0.3 1.9 0.4 251 7 245 165 12.4 0 12.5 12.2 06/29/2006 20:50:00 0.4 0 0.7 0.4 0.4 0 1.1 0.4 0.4 0.2 1.9 0.4 239 22 249 165 12.4 0 12.5 12.2 06/29/2006 21:00:00 0.5 0.2 1.5 0.4 0.6 0.4 1.5 0.4 0.8 0.5 1.9 0.4 180 10 190 165 12.2 0 12.5 11.9 06/29/2006 21:10:00 0.5 0.3 1.5 0.4 0.6 0.4 1.5 0.4 0.7 0.5 1.9 0.4 196 3 190 165 12 0 12.2 11.7 06/29/2006 21:20:00 0.4 0.2 1.5 0.4 0.7 0.4 2.3 0.4 0.8 0.4 1.9 0.4 238 20 259 165 11.9 0 12.2 11.4 06/29/2006 21:30:00 0.5 0.3 1.5 0.4 0.8 0.4 1.9 0.4 0.8 0.4 1.9 0.4 240 15 217 165 11.9 0.1 12.2 11.4 06/29/2006 21:40:00 1 0.5 1.9 0.4 1.2 0.5 2.3 0.4 1.4 0.4 2.3 0.4 180 19 177 165 11.8 0.1 12.2 11.4 06/29/2006 21:50:00 1.3 0.4 2.3 0.4 1.6 0.4 2.3 0.7 1.8 0.3 2.6 1.1 173 12 162 165 11.7 0 11.9 11.1 06/29/2006 22:00:00 2.8 0.8 5.3 1.1 3 0.8 5.3 1.5 3.1 0.8 5.3 1.5 190 13 204 165 11.7 0 11.9 11.1 06/29/2006 22:10:00 4.4 0.5 5.7 3 4.5 0.5 5.7 3 4.6 0.6 5.7 3 194 7 199 165 11.5 0 11.7 11.4 06/29/2006 22:20:00 6.1 1 8 3.4 6.2 1.1 8.4 3.8 6.2 1.2 8.4 2.6 198 8 204 165 11.3 0 11.7 11.1 06/29/2006 22:30:00 5.3 0.8 8 3.4 5.5 0.8 8.4 3.4 5.1 0.9 7.2 3 208 9 211 165 11.2 0 11.4 10.9 06/29/2006 22:40:00 6.1 0.7 8 3.8 6.2 0.7 8 3.8 6.1 0.8 8 3.8 198 8 207 165 11.1 0 11.4 10.9 06/29/2006 22:50:00 6.4 1.2 8.8 3.8 6.6 1.2 9.1 4.2 6.5 1.1 9.5 4.6 200 9 199 165 11.1 0 11.4 10.9 06/29/2006 23:00:00 7 1.2 9.5 4.2 7.1 1.2 9.5 4.6 7.1 1.2 9.9 4.2 197 8 210 165 11.1 0 11.4 10.9 06/29/2006 23:10:00 7.5 1.2 10.3 4.9 7.6 1.2 10.3 4.9 7.5 1.3 10.3 4.9 197 9 205 165 10.9 0 11.1 10.9 06/29/2006 23:20:00 7 0.5 8.4 5.7 6.9 0.5 8 5.7 7.1 0.5 8.8 5.7 183 10 178 165 10.8 0.1 11.1 10.6 06/29/2006 23:30:00 7.4 0.6 8.8 6.1 7.2 0.6 8.8 5.7 7.5 0.7 9.1 6.1 179 6 174 165 10.6 0.2 10.9 10.3 06/29/2006 23:40:00 7.2 0.8 9.1 4.9 7 0.8 8.8 4.9 7.2 0.8 8.8 4.9 180 7 190 165 10.6 0.2 10.9 10.3 06/29/2006 23:50:00 6.3 0.6 7.6 4.9 6.1 0.6 7.6 4.9 6.4 0.6 8 4.9 175 10 180 165 10.5 0.3 10.9 10.1 06/30/2006 00:00:00 6.6 0.8 8.8 4.2 6.4 0.8 8.4 4.2 6.7 0.8 8.8 4.6 175 8 182 165 10.5 0.2 10.9 9.8 06/30/2006 00:10:00 7.1 0.8 8.8 4.6 7 0.7 8.4 4.6 7.2 0.8 8.8 5.3 181 7 184 165 10.4 0.2 10.9 9.8 06/30/2006 00:20:00 7.2 0.7 9.1 5.3 7.1 0.7 9.1 5.3 7.3 0.7 9.1 5.7 180 7 189 165 10.3 0.2 10.9 9.8 06/30/2006 00:30:00 7.7 0.7 9.1 4.9 7.5 0.7 8.8 4.9 7.9 0.8 9.5 5.3 177 6 177 165 10.3 0.1 10.9 9.8 06/30/2006 00:40:00 7.2 0.8 8.8 4.6 7 0.7 8.4 4.9 7.3 0.8 9.1 5.3 180 7 183 165 10.3 0 10.6 9.8 06/30/2006 00:50:00 6.4 0.6 7.6 4.6 6.2 0.5 7.6 4.2 6.7 0.6 8 4.9 174 7 172 165 10.2 0.1 10.6 9.8 06/30/2006 01:00:00 7 0.6 8.4 5.3 6.8 0.6 8 4.9 7.1 0.6 8.8 4.6 176 6 180 165 10.3 0 10.6 9.8 06/30/2006 01:10:00 7.9 0.7 9.1 6.1 7.6 0.6 9.1 5.7 7.9 0.7 9.5 6.1 180 5 179 165 10.3 0 10.6 10.1 06/30/2006 01:20:00 7.6 0.7 9.5 5.3 7.5 0.7 9.1 5.3 7.9 0.7 9.5 6.1 178 12 177 165 10.3 0 10.6 10.1 06/30/2006 01:30:00 7 0.6 8.8 5.7 6.9 0.5 8 5.3 7.3 0.6 8.8 5.7 180 5 183 165 10.1 0 10.3 9.6 06/30/2006 01:40:00 7.4 0.5 8.8 6.5 7.2 0.5 8.4 6.1 7.5 0.6 9.1 6.1 178 5 179 165 10 0 10.3 9.6 06/30/2006 01:50:00 7.4 0.5 8.4 5.7 7.2 0.5 8.4 5.7 7.5 0.6 9.1 6.1 178 5 183 165 10 0 10.1 9.8 06/30/2006 02:00:00 7.1 0.6 8.8 5.3 6.9 0.6 8.8 5.3 7.2 0.7 9.1 5.7 179 7 190 165 10 0 10.3 9.6 06/30/2006 02:10:00 6.8 0.7 8.8 4.9 6.7 0.6 8.4 4.6 7 0.6 9.1 5.3 177 8 181 165 9.9 0 10.1 9.6 06/30/2006 02:20:00 6.3 0.6 8.8 4.2 6.2 0.6 8.8 4.2 6.5 0.6 8.8 4.9 178 7 184 165 9.9 0 10.1 9.6 06/30/2006 02:30:00 6.1 0.6 7.6 4.2 6 0.5 7.2 4.6 6.4 0.6 8 4.2 172 9 171 165 9.8 0.1 9.8 9.3 06/30/2006 02:40:00 6.4 0.6 7.6 4.9 6.3 0.5 7.6 4.6 6.5 0.5 8 4.9 178 8 193 165 9.7 0 9.8 9.3 06/30/2006 02:50:00 5.8 0.6 7.6 3.8 5.7 0.6 7.2 4.2 5.9 0.6 7.2 4.2 179 8 179 165 9.6 0.1 9.8 9.3 06/30/2006 03:00:00 5.4 0.6 6.8 3.8 5.3 0.6 6.5 3.4 5.6 0.5 6.8 4.2 177 6 176 165 9.6 0.1 9.8 9.3 06/30/2006 03:10:00 5.5 0.6 7.2 4.2 5.4 0.6 7.2 4.2 5.6 0.6 7.2 4.2 177 7 187 165 9.7 0 10.3 9.3 06/30/2006 03:20:00 5.5 0.6 7.2 3.8 5.4 0.6 6.8 3.8 5.6 0.6 7.2 4.2 174 7 177 165 9.6 0.1 9.8 9.3 06/30/2006 03:30:00 5.2 0.6 6.5 3.8 5.1 0.5 6.5 3.8 5.4 0.5 6.5 4.2 168 11 162 165 9.6 0.1 9.8 9.3 06/30/2006 03:40:00 6 0.5 7.2 4.9 5.8 0.5 7.2 4.9 6.1 0.6 7.6 4.9 170 9 176 165 9.7 0.1 10.3 9.3 06/30/2006 03:50:00 5.2 0.5 6.5 3.8 5.1 0.4 6.5 3.8 5.4 0.4 6.5 4.2 166 5 173 165 9.6 0.1 10.3 9.3 06/30/2006 04:00:00 5.6 0.5 6.8 4.2 5.5 0.4 6.5 4.2 5.7 0.5 6.8 3.8 171 6 165 165 9.6 0.1 10.1 9.3 06/30/2006 04:10:00 4.8 0.6 6.1 3.4 4.7 0.5 5.7 3.4 5 0.6 6.5 3.4 169 5 165 165 9.6 0.1 9.8 9 06/30/2006 04:20:00 4.6 0.4 5.3 3.4 4.5 0.4 5.3 3.4 4.8 0.4 5.7 3.8 167 4 172 165 9.6 0.2 9.6 9 06/30/2006 04:30:00 5 0.4 6.1 4.2 4.9 0.3 5.7 4.2 5.3 0.4 6.1 4.2 168 4 170 165 9.6 0.2 9.8 9 06/30/2006 04:40:00 4.8 0.4 5.7 3.8 4.7 0.4 5.3 3.8 5.1 0.3 5.7 4.2 170 11 165 165 9.5 0.2 9.6 9 06/30/2006 04:50:00 3.9 0.5 4.9 2.6 3.8 0.5 4.6 2.6 4.1 0.5 4.9 3 170 5 171 165 9.6 0.2 9.8 9 06/30/2006 05:00:00 2.8 0.3 3.4 2.3 2.9 0.3 3.4 2.3 3.2 0.3 3.8 2.3 169 6 165 165 9.7 0.1 10.1 9 06/30/2006 05:10:00 3.8 0.5 5.3 2.6 3.8 0.4 4.9 2.6 4 0.4 4.9 3 178 5 165 165 10 0.1 10.3 9.3 06/30/2006 05:20:00 3.7 0.5 4.9 1.9 3.7 0.5 4.6 2.3 3.9 0.4 4.9 2.6 175 8 179 165 10.1 0.1 10.3 9.6 06/30/2006 05:30:00 3.6 0.3 4.6 3 3.6 0.3 4.2 3 3.9 0.2 4.6 3.4 172 6 174 165 10 0 10.3 9.6 06/30/2006 05:40:00 3.1 0.4 3.8 2.3 3.1 0.3 3.8 2.3 3.3 0.4 4.2 2.6 171 5 168 165 10 0 10.3 9.6 06/30/2006 05:50:00 3.4 0.4 4.6 2.6 3.4 0.4 4.6 2.6 3.6 0.3 4.6 2.6 171 7 181 165 10 0 10.3 9.6 06/30/2006 06:00:00 3.2 0.8 5.3 0.4 3.2 0.8 5.3 0.7 3.5 0.6 5.3 1.9 172 9 183 165 10 0 10.3 9.6 06/30/2006 06:10:00 3.3 1 5.3 1.1 3.4 1 5.3 0.7 3.3 0.9 5.7 1.1 194 13 204 165 10.2 0 10.6 9.6 06/30/2006 06:20:00 3.4 0.6 4.9 1.5 3.4 0.6 4.9 1.5 3.3 0.5 4.6 1.9 193 9 189 165 10.3 0 10.6 9.8 06/30/2006 06:30:00 3.1 0.6 4.6 1.5 3.1 0.6 4.6 1.5 3.1 0.5 4.6 1.9 186 12 204 165 10.2 0.1 10.6 9.6 06/30/2006 06:40:00 1.9 0.9 3.8 0.4 1.9 0.9 3.8 0.4 2 0.9 3.8 0.4 197 15 197 165 10.3 0 10.6 9.8 06/30/2006 06:50:00 0.5 0.2 1.5 0.4 0.4 0.2 1.1 0.4 1 0.4 1.9 0.4 191 7 197 165 10.3 0 10.6 9.8 06/30/2006 07:00:00 0.5 0.2 1.1 0.4 0.4 0 0.7 0.4 0.7 0.3 1.5 0.4 263 43 296 165 10.4 0 10.6 10.1 06/30/2006 07:10:00 0.8 0.2 1.5 0.4 0.6 0.3 1.5 0.4 1.3 0.2 1.9 0.7 305 2 307 165 10.3 0.1 10.6 9.8 06/30/2006 07:20:00 1.7 0.3 2.3 0.7 1.7 0.4 2.3 0.7 1.9 0.3 2.6 1.1 321 8 322 165 10.3 0 10.6 9.8 06/30/2006 07:30:00 1.3 0.4 1.9 0.4 1.2 0.5 1.9 0.4 1.6 0.4 2.3 0.7 330 6 330 165 10.3 0 10.6 9.8 06/30/2006 07:40:00 0.8 0.3 1.5 0.4 0.6 0.3 1.5 0.4 1 0.3 1.5 0.4 310 13 302 165 10.3 0 10.6 10.1 06/30/2006 07:50:00 0.7 0.3 1.5 0.4 0.6 0.3 1.5 0.4 1 0.3 1.5 0.4 297 20 275 165 10.5 0.1 10.9 10.3 06/30/2006 08:00:00 0.4 0.2 1.5 0.4 0.4 0.2 1.5 0.4 0.4 0.2 1.5 0.4 261 32 243 165 10.7 0.1 11.1 10.3 06/30/2006 08:10:00 0.4 0.2 1.1 0.4 0.4 0.1 1.1 0.4 0.4 0.2 1.1 0.4 277 38 274 165 11.2 0.1 11.7 10.9 06/30/2006 08:20:00 0.4 0.2 1.9 0.4 0.4 0.2 1.9 0.4 0.4 0.2 1.9 0.4 330 56 146 165 11.3 0 11.7 10.9 06/30/2006 08:30:00 0.5 0.2 1.5 0.4 0.4 0.1 1.1 0.4 0.7 0.4 1.9 0.4 1 21 355 165 11.3 0.2 11.7 10.9 06/30/2006 08:40:00 0.6 0.3 1.5 0.4 0.5 0.3 1.5 0.4 0.9 0.4 1.9 0.4 337 20 351 165 11.1 0.2 11.7 10.9 06/30/2006 08:50:00 0.6 0.4 1.5 0.4 0.5 0.3 1.5 0.4 0.9 0.5 1.9 0.4 350 8 339 165 11.2 0.1 11.7 10.9 06/30/2006 09:00:00 0.5 0.3 1.5 0.4 0.4 0.1 1.1 0.4 0.8 0.5 1.9 0.4 343 8 333 165 11.5 0 11.7 11.1 06/30/2006 09:10:00 0.4 0.1 1.1 0.4 0.4 0 0.7 0.4 0.5 0.3 1.5 0.4 1 23 6 165 11.5 0 11.9 11.1 06/30/2006 09:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 28 6 165 165 11.6 0.1 11.7 11.1 06/30/2006 09:30:00 0.4 0 0.7 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 344 79 358 165 11.6 0.1 11.9 11.1 06/30/2006 09:40:00 0.4 0.2 1.1 0.4 0.4 0.2 1.1 0.4 0.5 0.3 1.9 0.4 354 112 130 165 11.5 0 11.7 11.1 06/30/2006 09:50:00 0.4 0.2 1.5 0.4 0.4 0.2 1.9 0.4 0.5 0.3 1.9 0.4 124 102 140 165 11.4 0 11.7 11.1 06/30/2006 10:00:00 1.1 0.6 2.6 0.4 0.8 0.5 2.3 0.4 1.4 0.5 2.6 0.4 356 12 7 165 11.4 0.1 11.7 11.1 06/30/2006 10:10:00 0.6 0.3 1.9 0.4 0.4 0.2 1.5 0.4 1 0.4 1.9 0.4 4 16 14 165 11.2 0.2 11.7 10.9 06/30/2006 10:20:00 0.4 0.1 1.1 0.4 0.4 0 1.1 0.4 0.6 0.3 1.5 0.4 341 11 347 165 11.6 0.1 11.9 11.4 06/30/2006 10:30:00 0.6 0.3 1.5 0.4 0.4 0.1 1.1 0.4 0.9 0.4 1.9 0.4 337 16 10 165 11.7 0.1 11.9 11.1 06/30/2006 10:40:00 0.7 0.4 1.9 0.4 0.5 0.3 1.5 0.4 0.8 0.5 2.3 0.4 330 8 345 165 11.7 0.2 11.9 11.4 06/30/2006 10:50:00 0.4 0 0.7 0.4 0.4 0 0.4 0.4 0.4 0.2 1.5 0.4 297 51 332 165 11.9 0 12.2 11.7 06/30/2006 11:00:00 0.4 0.1 1.1 0.4 0.4 0 0.4 0.4 0.4 0.1 1.1 0.4 310 61 345 165 12.1 0 12.2 11.7 06/30/2006 11:10:00 0.4 0.2 1.5 0.4 0.4 0.2 1.5 0.4 0.5 0.3 1.9 0.4 21 56 113 165 12.2 0 12.5 11.7 06/30/2006 11:20:00 0.4 0.2 1.5 0.4 0.4 0.2 1.9 0.4 0.5 0.3 2.3 0.4 52 28 70 165 12.2 0 12.5 11.7 06/30/2006 11:30:00 0.4 0.2 1.5 0.4 0.4 0.2 1.5 0.4 0.6 0.3 1.5 0.4 80 38 115 165 12.2 0 12.5 11.7 06/30/2006 11:40:00 0.4 0.2 1.5 0.4 0.4 0.2 1.5 0.4 0.7 0.4 1.5 0.4 99 18 87 165 12.2 0 12.5 11.9 06/30/2006 11:50:00 0.6 0.4 1.9 0.4 0.7 0.5 1.9 0.4 1 0.6 2.3 0.4 106 15 112 165 12.1 0 12.2 11.7 06/30/2006 12:00:00 0.7 0.3 1.9 0.4 0.7 0.4 1.9 0.4 1 0.5 2.3 0.4 115 14 117 165 12.1 0 12.5 11.9 06/30/2006 12:10:00 0.9 0.5 1.9 0.4 1 0.5 2.3 0.4 1.2 0.5 2.3 0.4 116 15 109 165 12.3 0 12.5 12.2 06/30/2006 12:20:00 1.2 0.5 2.3 0.4 1.3 0.6 2.3 0.4 1.6 0.5 2.6 0.4 120 12 138 165 12 0 12.2 11.9 06/30/2006 12:30:00 0.8 0.4 2.3 0.4 0.8 0.5 2.3 0.4 1.2 0.6 2.6 0.4 102 19 98 165 12.1 0 12.5 11.9 06/30/2006 12:40:00 0.8 0.5 2.3 0.4 0.8 0.5 2.3 0.4 0.9 0.5 3 0.4 67 36 9 165 12.8 0.1 13 12.5 06/30/2006 12:50:00 1 0.5 2.3 0.4 0.8 0.5 2.3 0.4 0.8 0.5 2.3 0.4 52 43 23 165 12.8 0.1 13 12.5 06/30/2006 13:00:00 0.6 0.4 2.3 0.4 0.6 0.4 2.3 0.4 0.5 0.3 1.9 0.4 73 39 10 165 12.9 0.3 13.3 12.2 06/30/2006 13:10:00 0.7 0.4 2.3 0.4 0.6 0.4 1.9 0.4 0.7 0.4 1.9 0.4 61 45 357 165 12.7 0.1 13 12.2 06/30/2006 13:20:00 0.5 0.3 1.5 0.4 0.5 0.3 1.9 0.4 0.5 0.3 1.9 0.4 90 76 50 165 12.5 0.2 13 11.9 06/30/2006 13:30:00 0.5 0.3 1.5 0.4 0.5 0.3 1.5 0.4 0.8 0.5 2.6 0.4 119 13 118 165 12.2 0.2 12.5 11.7 06/30/2006 13:40:00 0.5 0.4 1.9 0.4 0.5 0.3 1.9 0.4 0.6 0.5 1.9 0.4 113 12 122 165 12.1 0 12.2 11.9 06/30/2006 13:50:00 0.4 0.2 1.5 0.4 0.4 0.2 1.9 0.4 0.4 0.1 1.1 0.4 17 64 46 165 12.7 0.3 13 12.2 06/30/2006 14:00:00 1.5 0.5 2.6 0.4 1.4 0.5 2.6 0.4 1.7 0.4 2.6 0.4 18 15 7 165 13.1 0 13.3 12.5 06/30/2006 14:10:00 1.7 0.4 2.6 0.7 1.6 0.5 2.6 0.4 1.9 0.4 2.6 0.7 24 10 11 165 12.9 0.1 13.3 12.2 06/30/2006 14:20:00 1.8 0.3 2.6 1.1 1.6 0.4 2.6 0.7 2 0.4 3 0.7 19 9 23 165 12.7 0 13 12.2 06/30/2006 14:30:00 2.5 0.5 3.4 1.1 2.1 0.6 3.4 0.7 2.6 0.4 3.4 1.1 9 12 6 165 12.8 0.1 13 12.2 06/30/2006 14:40:00 3 0.5 4.2 1.9 2.6 0.6 4.2 1.1 3.3 0.5 4.6 2.3 6 13 16 165 12.9 0.1 13 12.5 06/30/2006 14:50:00 2.8 0.4 4.2 1.5 2.5 0.5 3.8 1.1 3 0.4 4.2 1.9 12 11 8 165 12.9 0.1 13.3 12.5 06/30/2006 15:00:00 2.7 0.5 4.2 1.1 2.3 0.6 4.2 1.1 3 0.4 4.6 1.9 6 10 29 165 13.3 0.1 13.5 12.7 06/30/2006 15:10:00 2.5 0.5 3.8 1.1 2.4 0.6 3.8 1.1 2.9 0.5 3.8 1.1 11 15 14 165 13.5 0 13.8 13 06/30/2006 15:20:00 2.2 0.6 3.8 0.7 2.1 0.6 3.4 0.4 2.6 0.5 3.4 1.1 13 11 20 165 13.1 0.1 13.5 12.7 06/30/2006 15:30:00 2.1 0.5 3.4 0.7 2.1 0.5 3.4 1.1 2.4 0.4 3.8 1.1 20 16 20 165 13 0.1 13.3 12.2 06/30/2006 15:40:00 1 0.5 2.3 0.4 1.3 0.5 2.6 0.4 1.4 0.5 2.3 0.4 25 21 34 165 12.7 0 12.7 12.2 06/30/2006 15:50:00 0.9 0.6 2.3 0.4 1 0.5 2.3 0.4 1.3 0.6 2.6 0.4 355 10 359 165 13.1 0.2 13.5 11.9 06/30/2006 16:00:00 1.4 0.4 2.3 0.4 1.3 0.4 2.6 0.4 1.9 0.3 3 1.1 4 11 8 165 13.5 0.1 13.8 13 06/30/2006 16:10:00 1.3 0.4 2.6 0.4 1.3 0.4 2.3 0.4 1.9 0.3 2.6 0.7 7 13 3 165 13.3 0 13.5 12.7 06/30/2006 16:20:00 1.5 0.5 3 0.4 1.5 0.5 2.6 0.4 1.9 0.5 3.4 0.7 12 15 10 165 13.4 0.1 13.8 12.7 06/30/2006 16:30:00 1.4 0.7 3 0.4 1.4 0.6 2.6 0.4 1.9 0.7 3.4 0.4 15 13 1 165 13.5 0 13.8 13 06/30/2006 16:40:00 0.5 0.3 1.5 0.4 0.6 0.4 1.9 0.4 0.6 0.4 1.9 0.4 22 28 52 165 13.9 0.2 14.4 13 06/30/2006 16:50:00 0.4 0.1 0.7 0.4 0.4 0.2 1.1 0.4 0.5 0.3 1.9 0.4 153 64 52 165 14.1 0 14.4 13.8 06/30/2006 17:00:00 0.5 0.2 1.5 0.4 0.5 0.3 1.9 0.4 0.5 0.4 1.9 0.4 128 56 1 165 13.6 0.2 14.1 13.3 06/30/2006 17:10:00 0.6 0.4 1.9 0.4 0.6 0.4 1.9 0.4 0.9 0.5 1.9 0.4 356 12 355 165 13.9 0.2 14.4 13.3 06/30/2006 17:20:00 0.7 0.4 1.9 0.4 0.8 0.5 2.3 0.4 0.8 0.5 2.3 0.4 5 22 358 165 14.4 0 14.6 13.8 06/30/2006 17:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 12 12 165 165 14.3 0 14.6 14.1 06/30/2006 17:40:00 0.4 0.2 1.5 0.4 0.5 0.3 1.5 0.4 0.4 0.2 1.5 0.4 44 30 54 165 14.2 0.2 14.6 13.5 06/30/2006 17:50:00 0.7 0.4 1.9 0.4 0.5 0.3 1.5 0.4 1 0.4 1.9 0.4 357 9 353 165 13.9 0.2 14.4 13.5 06/30/2006 18:00:00 0.4 0.2 1.1 0.4 0.4 0.2 1.1 0.4 0.6 0.3 1.5 0.4 2 15 358 165 14.1 0.1 14.4 13.5 06/30/2006 18:10:00 0.6 0.3 1.5 0.4 0.6 0.4 1.9 0.4 1 0.3 1.9 0.4 341 10 336 165 13.9 0 14.6 13.5 06/30/2006 18:20:00 0.4 0 0.7 0.4 0.4 0 0.4 0.4 0.4 0.2 1.1 0.4 343 1 339 165 13.4 0.2 13.8 13 06/30/2006 18:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 343 1 165 165 13.2 0.2 13.5 12.7 06/30/2006 18:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 343 0 165 165 13 0.1 13.3 12.7 06/30/2006 18:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0.1 1.5 0.4 318 35 165 165 13.2 0.1 13.5 12.7 06/30/2006 19:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0.1 0.7 0.4 288 0 165 165 13.3 0.1 13.5 13 06/30/2006 19:10:00 0.4 0 0.4 0.4 0.4 0 0.7 0.4 0.4 0.1 1.1 0.4 290 1 165 165 13.3 0 13.5 12.7 06/30/2006 19:20:00 0.4 0 0.4 0.4 0.4 0.2 1.1 0.4 0.7 0.3 1.5 0.4 309 4 165 165 13.2 0 13.5 12.7 06/30/2006 19:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 310 0 165 165 13.1 0 13.3 12.7 06/30/2006 19:40:00 0.4 0 0.7 0.4 0.4 0 0.4 0.4 0.4 0.1 1.1 0.4 312 4 311 165 13.1 0.2 13.3 12.5 06/30/2006 19:50:00 0.4 0.2 1.1 0.4 0.4 0.2 1.1 0.4 0.5 0.2 1.9 0.4 319 5 322 165 13 0 13.3 12.5 06/30/2006 20:00:00 1.4 0.3 2.3 0.4 1.2 0.4 2.3 0.4 1.8 0.4 2.3 0.7 347 6 346 165 13.1 0 13.3 12.7 06/30/2006 20:10:00 1.3 0.3 1.9 0.4 0.6 0.3 1.9 0.4 1.9 0.2 2.3 1.5 353 4 353 165 12.8 0 13 12.5 06/30/2006 20:20:00 1.5 0.2 2.3 0.7 0.8 0.4 1.9 0.4 1.9 0.2 2.3 1.5 5 4 2 165 12.9 0 13 12.5 06/30/2006 20:30:00 1 0.3 1.5 0.4 0.9 0.4 1.9 0.4 1.4 0.2 1.9 0.7 14 7 16 165 12.6 0 13 12.5 06/30/2006 20:40:00 0.6 0.3 1.5 0.4 0.5 0.3 1.5 0.4 1.1 0.3 1.9 0.7 10 0 10 165 12.4 0 12.7 12.2 06/30/2006 20:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0.1 1.1 0.4 10 0 165 165 12.4 0 12.5 12.5 06/30/2006 21:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 10 0 165 165 12.5 0 12.7 12.2 06/30/2006 21:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 10 0 165 165 12.7 0 12.7 12.5 06/30/2006 21:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 10 0 165 165 12.7 0 12.7 12.5 06/30/2006 21:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0.1 1.1 0.4 301 43 165 165 12.7 0 12.7 12.5 06/30/2006 21:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 269 0 165 165 12.6 0 12.7 12.5 06/30/2006 21:50:00 0.4 0 0.4 0.4 0.4 0.1 0.7 0.4 0.5 0.2 1.1 0.4 284 8 165 165 12.4 0 12.7 12.2 06/30/2006 22:00:00 0.4 0 0.7 0.4 0.4 0.1 1.1 0.4 0.8 0.5 1.9 0.4 290 6 284 165 12.5 0 12.7 12.2 06/30/2006 22:10:00 1.1 0.8 2.3 0.4 1.2 0.9 2.6 0.4 1.4 0.7 2.6 0.4 288 9 282 165 12.6 0 12.7 12.5 06/30/2006 22:20:00 2 0.4 3 0.7 2.2 0.4 3.4 0.7 2 0.5 3.4 1.1 282 11 277 165 12.7 0 13 12.5 06/30/2006 22:30:00 2.7 0.6 4.6 0.7 2.9 0.6 4.2 1.5 3.2 0.5 4.6 1.9 281 9 268 165 12.8 0 13 12.7 06/30/2006 22:40:00 2.8 0.3 3.4 1.9 3 0.3 3.8 2.3 2.7 0.5 4.2 1.5 290 7 275 165 12.7 0 13 12.5 06/30/2006 22:50:00 1.9 0.5 3 0.7 2.2 0.5 3.4 1.1 1.8 0.4 3 0.7 298 6 302 165 12.6 0 13 12.5 06/30/2006 23:00:00 1.7 0.3 2.6 1.1 2 0.2 2.6 1.1 1.8 0.4 2.6 0.7 287 8 304 165 12.5 0 12.7 12.2 06/30/2006 23:10:00 2.3 0.5 3.4 1.1 2.5 0.5 3.4 1.5 2.1 0.6 3.4 0.7 291 8 286 165 12.4 0 12.7 12.2 06/30/2006 23:20:00 1.8 0.4 3 1.1 2 0.4 3 1.1 1.7 0.5 3 0.7 297 5 293 165 12.1 0 12.5 11.9 06/30/2006 23:30:00 2.3 0.4 3.4 1.1 2.5 0.4 3.4 1.5 1.8 0.4 3 1.1 294 4 295 165 12 0 12.2 11.7 06/30/2006 23:40:00 3 0.4 3.8 1.9 3 0.4 4.2 1.9 2.7 0.5 3.8 1.5 303 9 286 165 11.9 0 12.2 11.7 06/30/2006 23:50:00 2.7 0.4 4.2 1.9 2.8 0.4 4.6 1.9 2.7 0.3 3.4 1.9 312 7 304 165 11.7 0.1 12.2 11.4 07/01/2006 00:00:00 2.8 0.4 3.8 1.9 2.9 0.4 3.8 2.3 2.8 0.3 3.4 1.9 311 6 322 165 11.7 0.1 11.9 11.4 07/01/2006 00:10:00 2.8 0.4 3.8 1.9 2.9 0.4 3.8 1.9 2.8 0.4 3.8 1.9 310 5 310 165 11.7 0.2 11.9 11.4 07/01/2006 00:20:00 3.4 0.6 5.3 2.3 3.5 0.6 5.3 2.3 3.1 0.5 4.9 1.9 307 11 293 165 11.7 0.1 11.9 11.4 07/01/2006 00:30:00 3.5 0.7 5.3 1.1 3.7 0.7 5.3 1.1 3.2 0.6 4.9 1.5 296 10 287 165 11.7 0.1 11.9 11.4 07/01/2006 00:40:00 3.3 0.7 4.9 1.5 3.7 0.5 4.9 2.3 3.4 0.6 4.9 1.9 276 10 281 165 11.7 0.1 12.2 11.4 07/01/2006 00:50:00 1.2 0.5 3 0.4 1.7 0.7 3.4 0.4 1.5 0.7 3.4 0.4 248 18 262 165 11.6 0.2 11.9 11.1 07/01/2006 01:00:00 1 0.6 3 0.4 1.2 0.7 2.6 0.4 0.9 0.4 2.3 0.4 234 19 286 165 11.3 0.1 11.7 10.9 07/01/2006 01:10:00 2 0.9 3.4 0.4 2.3 0.9 3.4 0.4 2.2 0.9 3.4 0.4 274 9 283 165 11.4 0.2 11.9 10.9 07/01/2006 01:20:00 1.5 0.6 2.6 0.4 1.8 0.6 2.6 0.4 1.9 0.5 3 0.7 271 9 282 165 11.5 0.2 11.9 11.1 07/01/2006 01:30:00 0.7 0.4 1.9 0.4 0.9 0.4 1.9 0.4 1.1 0.4 1.9 0.4 252 15 221 165 11.3 0.2 11.7 10.9 07/01/2006 01:40:00 1.5 0.4 2.3 0.4 2 0.3 3 1.1 1.9 0.3 2.6 1.1 247 11 220 165 11.3 0.2 11.7 10.9 07/01/2006 01:50:00 2 0.5 3 0.7 2.4 0.4 3 1.5 2.3 0.4 3 1.5 271 7 282 165 11.5 0.2 11.7 10.9 07/01/2006 02:00:00 2.3 0.6 3.8 0.4 2.5 0.5 3.8 1.1 2.5 0.5 3.8 1.5 279 9 278 165 11.5 0.2 11.7 11.1 07/01/2006 02:10:00 1.8 1 4.2 0.4 2.4 0.7 4.2 0.7 2.3 0.6 3.8 1.1 261 13 285 165 11.5 0.1 11.7 11.1 07/01/2006 02:20:00 1.6 0.5 2.6 0.4 2.2 0.5 3.4 0.7 2.2 0.4 3 1.1 253 7 242 165 11.5 0 11.7 11.1 07/01/2006 02:30:00 2.5 0.5 3.4 1.1 3 0.3 3.4 2.3 2.9 0.3 3.8 2.3 272 5 277 165 11.5 0 11.7 11.1 07/01/2006 02:40:00 2.7 0.4 3.8 1.9 2.9 0.4 3.8 1.9 3 0.4 4.2 2.3 279 4 284 165 11.5 0 11.7 11.1 07/01/2006 02:50:00 1.8 0.4 2.6 0.7 2.1 0.3 3 1.1 2.1 0.3 3 1.1 280 6 279 165 11.5 0 11.7 11.1 07/01/2006 03:00:00 2.1 0.4 3 1.1 2.2 0.3 3 1.1 2 0.4 2.6 1.1 289 6 299 165 11.5 0 11.7 11.1 07/01/2006 03:10:00 2.1 0.5 3.4 1.1 2.3 0.5 3.4 1.1 2.2 0.5 3 0.7 288 8 282 165 11.5 0 11.7 11.1 07/01/2006 03:20:00 2.5 0.5 3.4 1.5 2.7 0.5 3.8 1.5 2.5 0.5 3.4 1.5 286 6 284 165 11.5 0 11.7 11.1 07/01/2006 03:30:00 1.4 0.5 2.6 0.4 1.9 0.5 3 0.7 2 0.4 3 1.1 269 9 279 165 11.5 0 11.7 11.4 07/01/2006 03:40:00 1.1 0.7 2.6 0.4 1.4 0.7 2.6 0.4 1.5 0.7 2.6 0.4 277 8 285 165 11.5 0 11.7 11.4 07/01/2006 03:50:00 1.3 0.5 2.3 0.4 1.6 0.5 2.6 0.4 1.6 0.4 2.6 0.7 276 12 266 165 11.4 0 11.7 11.1 07/01/2006 04:00:00 0.7 0.4 1.5 0.4 1 0.4 1.9 0.4 1.3 0.3 1.9 0.4 262 10 287 165 11.3 0 11.4 11.1 07/01/2006 04:10:00 1.5 0.7 3.4 0.4 1.9 0.7 3.4 0.4 1.9 0.6 3 0.7 251 10 247 165 11.3 0 11.4 11.1 07/01/2006 04:20:00 2 0.6 3.4 0.7 2.5 0.5 3.8 1.1 2.4 0.4 3.8 1.5 252 8 247 165 11.3 0 11.4 11.1 07/01/2006 04:30:00 2.2 0.6 3.4 0.7 2.7 0.4 3.4 1.5 2.7 0.3 3.4 1.9 263 11 245 165 11.3 0 11.4 11.1 07/01/2006 04:40:00 1.9 0.4 3 0.7 2.1 0.4 3.4 1.5 2 0.6 3.4 0.7 278 13 285 165 11.3 0 11.4 11.1 07/01/2006 04:50:00 1.3 0.3 2.3 0.4 1.5 0.3 2.3 0.7 1.3 0.3 1.9 0.7 299 5 293 165 11.3 0 11.9 11.1 07/01/2006 05:00:00 1.3 0.3 2.3 0.4 1.6 0.3 2.3 0.7 1.7 0.3 2.3 1.1 311 5 317 165 11.3 0 11.4 11.1 07/01/2006 05:10:00 1.2 0.4 2.3 0.4 1.4 0.4 2.3 0.4 1.5 0.4 3 0.7 300 10 307 165 11.3 0 11.4 11.1 07/01/2006 05:20:00 0.6 0.3 1.5 0.4 0.8 0.3 1.9 0.4 1.2 0.3 1.9 0.4 303 14 301 165 11.3 0 11.4 11.1 07/01/2006 05:30:00 0.4 0.2 1.1 0.4 0.4 0.2 1.1 0.4 0.9 0.4 1.9 0.4 305 22 310 165 11.3 0 11.9 11.4 07/01/2006 05:40:00 1.5 0.6 3 0.4 1.4 0.6 3 0.4 2 0.6 3.4 1.1 5 19 31 165 11.4 0.1 11.9 10.9 07/01/2006 05:50:00 0.7 0.2 1.5 0.4 0.6 0.3 1.5 0.4 1.3 0.5 2.6 0.4 327 19 355 165 11.1 0 11.1 10.9 07/01/2006 06:00:00 0.4 0.1 1.1 0.4 0.4 0.1 1.1 0.4 0.4 0.1 1.1 0.4 320 8 310 165 11.1 0 11.4 10.9 07/01/2006 06:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0.1 1.1 0.4 322 4 165 165 11.1 0 11.4 10.9 07/01/2006 06:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.7 0.4 316 0 165 165 11.2 0 11.4 10.9 07/01/2006 06:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 316 0 165 165 11.2 0 11.4 10.9 07/01/2006 06:40:00 0.4 0.1 0.7 0.4 0.4 0.1 0.7 0.4 0.4 0 0.7 0.4 281 22 260 165 11.3 0 11.7 11.1 07/01/2006 06:50:00 0.4 0.1 0.7 0.4 0.4 0.1 1.1 0.4 0.4 0.2 1.5 0.4 266 5 273 165 11.3 0.2 11.7 10.9 07/01/2006 07:00:00 0.4 0.2 1.5 0.4 0.5 0.3 1.9 0.4 0.5 0.3 1.9 0.4 267 12 305 165 11.3 0.1 11.7 10.9 07/01/2006 07:10:00 0.6 0.3 1.5 0.4 0.8 0.4 1.9 0.4 0.9 0.5 2.3 0.4 249 24 266 165 11.5 0.1 11.7 11.1 07/01/2006 07:20:00 1.1 0.5 2.3 0.4 1.4 0.5 2.3 0.4 1.6 0.3 2.6 0.7 240 26 245 165 11.5 0.2 11.9 11.1 07/01/2006 07:30:00 1.5 0.5 2.3 0.4 1.6 0.5 2.6 0.4 2 0.4 3 0.7 211 15 226 165 11.4 0.2 11.7 10.9 07/01/2006 07:40:00 0.9 0.5 2.3 0.4 0.9 0.6 2.3 0.4 1.2 0.6 2.6 0.4 220 22 229 165 11.5 0.2 11.9 11.1 07/01/2006 07:50:00 0.9 0.5 2.3 0.4 1.2 0.6 2.3 0.4 1.1 0.6 2.6 0.4 251 19 264 165 11.9 0.2 12.5 11.4 07/01/2006 08:00:00 0.7 0.5 2.3 0.4 0.8 0.6 2.6 0.4 1 0.6 2.6 0.4 251 28 249 165 12.3 0 12.5 11.9 07/01/2006 08:10:00 0.5 0.3 1.5 0.4 0.5 0.3 1.5 0.4 0.6 0.4 1.9 0.4 185 36 164 165 12.3 0 12.5 12.2 07/01/2006 08:20:00 0.6 0.4 1.9 0.4 0.6 0.4 1.9 0.4 0.6 0.4 1.9 0.4 202 27 216 165 12.3 0 12.5 11.9 07/01/2006 08:30:00 0.6 0.4 1.9 0.4 0.5 0.4 1.9 0.4 0.6 0.4 2.3 0.4 207 22 242 165 12.6 0.1 13 11.9 07/01/2006 08:40:00 0.5 0.2 1.5 0.4 0.4 0.2 1.5 0.4 0.5 0.3 1.5 0.4 214 29 217 165 12.4 0 12.7 12.2 07/01/2006 08:50:00 0.6 0.3 1.5 0.4 0.5 0.2 1.5 0.4 0.7 0.5 1.9 0.4 187 26 230 165 12.8 0.2 13.3 11.9 07/01/2006 09:00:00 0.5 0.3 1.5 0.4 0.4 0.2 1.5 0.4 0.7 0.4 1.9 0.4 223 15 222 165 12.7 0.1 13 11.9 07/01/2006 09:10:00 0.5 0.3 1.5 0.4 0.5 0.3 1.5 0.4 0.6 0.3 1.5 0.4 212 39 236 165 13.1 0 13.3 12.5 07/01/2006 09:20:00 0.7 0.5 2.3 0.4 0.6 0.5 2.3 0.4 0.9 0.7 2.6 0.4 160 35 154 165 12.9 0.1 13.3 12.2 07/01/2006 09:30:00 0.8 0.5 2.3 0.4 0.7 0.5 2.3 0.4 1.1 0.6 2.6 0.4 155 24 141 165 12.7 0.1 13 12.2 07/01/2006 09:40:00 1 0.5 2.6 0.4 0.9 0.5 2.6 0.4 1.5 0.4 2.6 0.7 150 12 139 165 12.6 0.1 13 11.9 07/01/2006 09:50:00 0.6 0.3 1.5 0.4 0.5 0.3 1.9 0.4 0.9 0.4 1.9 0.4 139 21 138 165 12.2 0.1 13 11.7 07/01/2006 10:00:00 0.9 0.5 2.3 0.4 0.9 0.6 2.3 0.4 1.5 0.5 3 0.4 144 21 163 165 12.3 0 12.7 11.9 07/01/2006 10:10:00 1.3 0.4 3 0.4 1.3 0.5 3 0.4 1.7 0.3 2.6 1.1 147 12 165 165 12.1 0 12.2 11.4 07/01/2006 10:20:00 0.8 0.3 1.5 0.4 0.7 0.4 1.5 0.4 1.4 0.3 2.3 0.4 152 12 168 165 11.7 0.2 12.2 11.1 07/01/2006 10:30:00 1.1 0.5 2.3 0.4 1.1 0.5 2.6 0.4 1.7 0.4 3 0.7 158 7 153 165 11.8 0.1 12.2 11.4 07/01/2006 10:40:00 0.8 0.5 2.6 0.4 0.7 0.5 2.6 0.4 1.4 0.5 3 0.4 153 18 165 165 11.8 0.1 11.9 11.4 07/01/2006 10:50:00 0.9 0.5 2.3 0.4 1 0.5 2.3 0.4 1.5 0.4 2.6 0.7 148 10 153 165 12.1 0.1 12.5 11.7 07/01/2006 11:00:00 1.9 0.4 2.6 0.7 1.9 0.4 3 0.4 2.3 0.3 3 1.5 148 8 154 165 12.2 0.2 12.7 11.7 07/01/2006 11:10:00 1.8 0.4 2.6 1.1 1.9 0.3 3 1.1 2.2 0.4 3 1.5 149 10 157 165 11.7 0.1 12.2 11.4 07/01/2006 11:20:00 1.6 0.4 2.6 0.7 1.9 0.4 2.6 0.7 2.1 0.4 3 0.7 145 9 145 165 11.7 0.1 11.9 11.1 07/01/2006 11:30:00 1.6 0.5 3 0.4 1.9 0.5 3.4 0.4 2 0.5 3.4 0.7 150 9 138 165 11.8 0.2 12.2 11.1 07/01/2006 11:40:00 2.1 0.4 3.4 1.1 2.4 0.4 3.4 1.5 2.5 0.3 3.4 1.5 146 12 139 165 11.7 0 11.9 11.1 07/01/2006 11:50:00 2.2 0.4 3.4 0.7 2.4 0.3 3.4 1.1 2.6 0.3 3.4 1.5 157 9 153 165 12 0.1 12.2 11.7 07/01/2006 12:00:00 2.2 0.4 3 1.1 2.4 0.4 3.4 1.1 2.6 0.5 3.8 1.1 154 9 155 165 12 0 12.7 11.7 07/01/2006 12:10:00 2.1 0.4 3.4 1.1 2.4 0.4 3.4 1.5 2.5 0.4 3.8 1.5 149 14 165 165 12.1 0.2 12.5 11.4 07/01/2006 12:20:00 1.5 0.5 2.6 0.4 1.8 0.4 2.6 0.7 2 0.4 3.4 0.7 158 11 151 165 11.9 0.2 12.5 11.4 07/01/2006 12:30:00 1.9 0.5 3 0.7 2.2 0.4 3 1.1 2.3 0.4 3.4 1.5 151 9 148 165 11.9 0.1 12.5 11.7 07/01/2006 12:40:00 2 0.4 3 0.7 2.2 0.3 3.4 1.1 2.3 0.3 3.4 1.5 153 8 151 165 12.3 0 12.5 12.2 07/01/2006 12:50:00 1.8 0.4 3.4 0.7 2.1 0.4 3.8 1.1 2.2 0.4 3.4 1.5 151 9 152 165 12.4 0 12.7 12.2 07/01/2006 13:00:00 2.1 0.5 3.4 0.7 2.3 0.5 3.8 1.5 2.4 0.4 3.8 1.1 151 11 165 165 12.7 0.1 13 12.5 07/01/2006 13:10:00 2.5 0.5 3.8 1.1 2.7 0.5 3.8 1.5 2.8 0.4 3.8 1.5 145 11 139 165 13 0.1 13.3 12.7 07/01/2006 13:20:00 2.3 0.6 3.8 0.7 2.6 0.5 4.2 1.1 2.8 0.5 4.2 1.5 128 12 123 165 12.9 0.1 13.5 12.5 07/01/2006 13:30:00 2.4 0.7 3.8 0.4 2.7 0.6 4.2 1.1 2.8 0.6 4.6 1.1 126 15 131 165 13.4 0 13.5 13.3 07/01/2006 13:40:00 1.8 0.6 3.4 0.4 2.2 0.5 4.2 1.1 2.4 0.6 3.8 1.1 118 13 128 165 13.6 0 13.8 13.3 07/01/2006 13:50:00 1.5 0.6 2.6 0.4 1.9 0.6 3 0.4 1.9 0.6 3.4 0.7 120 16 124 165 14 0 14.4 13.8 07/01/2006 14:00:00 0.9 0.6 2.6 0.4 1.3 0.6 2.6 0.4 1.4 0.7 3 0.4 105 28 72 165 14.4 0.2 14.9 14.1 07/01/2006 14:10:00 0.7 0.5 2.6 0.4 1.1 0.6 3 0.4 1.5 0.6 3 0.4 135 21 137 165 14.6 0 14.9 14.4 07/01/2006 14:20:00 0.9 0.6 2.3 0.4 1.3 0.6 3 0.4 1.4 0.6 3 0.4 104 32 108 165 15.2 0.2 15.7 14.6 07/01/2006 14:30:00 1.3 0.5 2.6 0.4 1.7 0.4 3 0.4 1.8 0.6 3 0.4 124 18 119 165 15.5 0 15.7 15.2 07/01/2006 14:40:00 1.3 0.6 3 0.4 1.6 0.5 3.4 0.4 1.9 0.6 3.4 0.4 140 15 131 165 15.5 0.2 16 15.2 07/01/2006 14:50:00 1.6 0.7 3.4 0.4 2 0.6 3.8 0.4 2.2 0.5 4.2 1.1 136 18 132 165 15.6 0 16 15.5 07/01/2006 15:00:00 1.2 0.7 3 0.4 1.8 0.5 3.4 0.4 2.1 0.5 3 0.4 130 19 144 165 15.5 0 15.7 15.5 07/01/2006 15:10:00 1 0.8 3.4 0.4 1.5 0.7 3.4 0.4 1.8 0.6 3.8 0.4 123 27 135 165 15.7 0 16 15.5 07/01/2006 15:20:00 1.8 0.6 3 0.4 2.2 0.5 3.4 0.7 2.3 0.5 3.4 0.7 139 16 137 165 15.9 0.1 16.3 15.5 07/01/2006 15:30:00 1.1 0.7 2.6 0.4 1.6 0.6 3 0.4 1.9 0.4 3 0.7 138 22 165 165 15.9 0 16.3 15.7 07/01/2006 15:40:00 1.3 0.9 3 0.4 1.7 0.8 3.4 0.4 1.9 0.6 3.4 0.4 133 20 126 165 16.1 0.1 16.3 15.7 07/01/2006 15:50:00 1.7 0.6 3.4 0.4 2.1 0.5 3.4 1.1 2.3 0.5 3.8 1.1 140 11 149 165 16.5 0.1 16.8 16.3 07/01/2006 16:00:00 1.6 0.5 3 0.4 2.1 0.4 3.4 0.7 2.3 0.4 3.4 1.1 128 12 145 165 16 0 16.3 15.7 07/01/2006 16:10:00 1.7 0.6 3 0.4 2.2 0.5 3.4 0.7 2.3 0.5 3.4 0.7 127 13 121 165 16.4 0.1 16.8 16 07/01/2006 16:20:00 0.7 0.5 2.6 0.4 1.3 0.5 2.6 0.4 1.4 0.5 2.6 0.4 127 26 127 165 16.4 0 16.8 16.3 07/01/2006 16:30:00 0.8 0.5 1.9 0.4 1.5 0.4 2.3 0.7 1.7 0.3 2.3 0.7 144 13 130 165 16.5 0 16.8 16.6 07/01/2006 16:40:00 0.7 0.5 2.3 0.4 1.3 0.6 2.6 0.4 1.3 0.6 3 0.4 129 33 151 165 16.9 0.2 17.4 16.6 07/01/2006 16:50:00 0.6 0.4 1.9 0.4 1.1 0.5 2.3 0.4 1.1 0.5 2.6 0.4 156 23 157 165 17.2 0 17.4 16.8 07/01/2006 17:00:00 0.4 0.2 1.5 0.4 0.7 0.5 1.9 0.4 0.7 0.4 1.9 0.4 162 10 176 165 17.6 0.2 18.2 17.1 07/01/2006 17:10:00 0.4 0.2 1.5 0.4 0.8 0.4 1.9 0.4 0.9 0.4 2.3 0.4 166 19 165 165 17.7 0.1 18.2 17.4 07/01/2006 17:20:00 0.4 0.1 1.1 0.4 0.8 0.4 1.9 0.4 0.5 0.3 1.5 0.4 229 18 245 165 17.8 0 18 17.7 07/01/2006 17:30:00 0.4 0.1 0.7 0.4 0.5 0.3 1.5 0.4 0.4 0.1 1.1 0.4 185 86 278 165 18.2 0.2 18.5 17.7 07/01/2006 17:40:00 1.1 0.7 2.6 0.4 1.1 0.6 2.3 0.4 0.8 0.6 2.3 0.4 352 39 336 165 19 0.4 20 18.5 07/01/2006 17:50:00 1.7 0.5 2.6 0.4 1.6 0.4 3 0.4 1.7 0.5 2.6 0.7 344 15 342 165 20.1 0 20.5 19.7 07/01/2006 18:00:00 1.4 0.5 3 0.4 1.5 0.5 3 0.4 1.3 0.5 2.6 0.4 325 16 318 165 20 0.1 20.2 20 07/01/2006 18:10:00 0.9 0.6 2.6 0.4 1.1 0.6 2.6 0.4 0.7 0.5 2.6 0.4 314 29 357 165 19.6 0.2 20.2 19.1 07/01/2006 18:20:00 0.9 0.6 2.6 0.4 1 0.6 2.3 0.4 0.9 0.7 2.6 0.4 317 33 347 165 19.5 0.1 20 19.1 07/01/2006 18:30:00 1 0.6 2.3 0.4 1.3 0.6 2.6 0.4 1.2 0.6 3 0.4 317 17 309 165 19.7 0 20 19.7 07/01/2006 18:40:00 1 0.6 3 0.4 1.3 0.6 2.6 0.4 1.2 0.5 2.6 0.4 346 21 4 165 19.9 0 20 19.7 07/01/2006 18:50:00 1 0.5 2.3 0.4 1.4 0.5 2.6 0.4 1.5 0.5 2.6 0.4 344 14 328 165 19.7 0 20 19.7 07/01/2006 19:00:00 0.9 0.5 2.3 0.4 1.3 0.4 2.6 0.4 1.2 0.4 2.6 0.4 333 10 326 165 19.3 0 19.7 19.1 07/01/2006 19:10:00 1.6 0.5 2.6 0.4 1.6 0.5 2.6 0.7 1.9 0.4 3 1.1 344 12 330 165 19.2 0 19.4 19.1 07/01/2006 19:20:00 1.7 0.4 2.6 0.7 1.7 0.4 2.6 0.7 2 0.4 3 1.1 351 8 341 165 18.9 0 19.4 18.5 07/01/2006 19:30:00 1 0.5 2.6 0.4 1.3 0.4 2.3 0.4 1.3 0.4 1.9 0.4 343 13 359 165 18.8 0 19.1 18.5 07/01/2006 19:40:00 0.7 0.4 2.3 0.4 1 0.5 2.3 0.4 0.8 0.4 1.9 0.4 326 17 310 165 18.9 0 19.1 18.5 07/01/2006 19:50:00 0.7 0.4 1.9 0.4 1.1 0.4 2.3 0.4 0.8 0.4 2.3 0.4 325 12 321 165 18.7 0 19.1 18.5 07/01/2006 20:00:00 0.6 0.3 1.5 0.4 0.9 0.4 1.9 0.4 0.9 0.4 1.9 0.4 330 17 333 165 18.4 0 18.5 18.2 07/01/2006 20:10:00 0.5 0.2 1.5 0.4 0.9 0.4 1.9 0.4 0.8 0.4 1.5 0.4 326 17 294 165 18.1 0 18.2 18 07/01/2006 20:20:00 0.9 0.5 2.3 0.4 1.3 0.5 2.3 0.4 0.8 0.4 1.9 0.4 312 22 284 165 17.8 0 18 17.4 07/01/2006 20:30:00 1.7 0.6 2.6 0.4 2 0.5 3 0.4 1.1 0.5 2.3 0.4 289 13 291 165 17.2 0 17.4 16.8 07/01/2006 20:40:00 2 0.5 3.8 0.7 2.3 0.5 3.4 1.1 1.3 0.6 3 0.4 281 7 289 165 16.8 0 17.1 16.6 07/01/2006 20:50:00 3.4 0.3 4.2 2.6 3.5 0.3 4.2 2.6 2.8 0.5 3.8 1.5 290 3 288 165 16.7 0 16.8 16.6 07/01/2006 21:00:00 3.6 0.3 4.2 2.6 3.8 0.3 4.6 3 3.6 0.3 4.6 2.6 279 5 284 165 16.8 0 16.8 16.6 07/01/2006 21:10:00 2.9 0.6 4.2 1.5 3.3 0.5 4.6 2.3 2.8 0.6 4.2 1.5 276 4 278 165 16.8 0 16.8 16.6 07/01/2006 21:20:00 1.1 0.6 2.6 0.4 1.6 0.7 3.4 0.4 1.1 0.7 3 0.4 248 35 280 165 16 0.3 16.8 15.2 07/01/2006 21:30:00 1.6 1.1 3.8 0.4 2 1.2 4.2 0.4 1.4 1 3.8 0.4 264 21 274 165 15.2 0.1 15.7 14.9 07/01/2006 21:40:00 2.2 0.3 3 1.5 2.5 0.3 3.4 1.9 1.9 0.5 3.4 1.1 290 5 284 165 15.5 0 15.7 15.2 07/01/2006 21:50:00 1.3 0.5 2.6 0.4 1.7 0.4 2.6 1.1 0.9 0.4 2.3 0.4 292 7 286 165 15.1 0.1 15.7 14.6 07/01/2006 22:00:00 0.8 0.7 2.6 0.4 1 0.8 3 0.4 0.6 0.4 1.9 0.4 298 5 290 165 14.6 0.1 15.2 14.4 07/01/2006 22:10:00 1.1 0.8 3 0.4 1.4 0.8 3 0.4 1 0.7 2.6 0.4 295 6 290 165 14.5 0.1 14.9 13.8 07/01/2006 22:20:00 2.3 0.6 3.8 0.7 2.6 0.5 4.2 1.1 2 0.5 3 1.1 284 8 297 165 14.8 0 15.2 14.4 07/01/2006 22:30:00 3 0.5 3.8 1.5 3.3 0.4 4.2 2.3 2.7 0.5 3.8 1.5 282 7 284 165 14.9 0 15.2 14.4 07/01/2006 22:40:00 3.2 0.8 5.3 1.1 3.5 0.7 5.3 1.9 3.1 0.7 4.9 1.5 282 8 286 165 14.8 0.1 15.2 14.4 07/01/2006 22:50:00 2.6 0.4 3.8 1.9 2.9 0.4 3.8 1.9 2.3 0.5 3.4 1.1 294 10 290 165 15 0 15.5 14.6 07/01/2006 23:00:00 1.9 0.4 2.6 1.1 2.2 0.3 3 1.5 1.9 0.3 3 1.1 310 6 317 165 15 0 15.2 14.6 07/01/2006 23:10:00 1.2 0.5 2.3 0.4 1.6 0.4 2.6 0.4 1.7 0.4 3 0.7 314 13 296 165 15 0.1 15.2 14.6 07/01/2006 23:20:00 1.6 0.5 3 0.4 2 0.4 3.4 1.1 1.8 0.5 3.4 0.7 301 9 291 165 15.3 0 15.5 14.6 07/01/2006 23:30:00 2.8 0.6 4.2 1.1 3 0.5 4.6 1.9 2.3 0.5 3.8 1.1 301 10 297 165 15.2 0.1 15.7 14.6 07/01/2006 23:40:00 2.8 0.5 4.2 1.5 3.1 0.4 4.2 1.9 2.5 0.5 3.8 1.5 301 8 307 165 15 0.1 15.2 14.6 07/01/2006 23:50:00 3.4 0.8 5.7 1.9 3.6 0.7 5.7 1.9 2.8 0.7 4.9 1.5 304 6 310 165 15.1 0 15.5 14.6 07/02/2006 00:00:00 3.8 0.5 5.7 2.6 3.9 0.5 5.7 2.6 3.3 0.5 5.3 1.9 310 6 305 165 15.2 0 15.5 15.2 07/02/2006 00:10:00 4.3 0.6 6.1 3 4.4 0.6 6.1 3 3.6 0.4 4.9 2.6 309 5 306 165 15.2 0 15.5 15.2 07/02/2006 00:20:00 3.9 0.5 5.3 3 4 0.4 5.3 3 3.4 0.5 4.6 2.3 309 6 294 165 15.2 0 15.5 15.2 07/02/2006 00:30:00 3.5 0.4 4.6 2.3 3.6 0.4 4.9 2.6 3.1 0.4 4.2 2.3 312 5 313 165 15.2 0 15.5 15.2 07/02/2006 00:40:00 2.6 0.6 3.8 1.1 2.7 0.6 3.8 1.5 2.5 0.4 3.4 1.5 314 8 305 165 15.2 0.1 15.5 15.2 07/02/2006 00:50:00 0.7 0.5 2.3 0.4 0.8 0.5 2.3 0.4 1 0.6 2.6 0.4 325 17 327 165 15.1 0 15.5 14.9 07/02/2006 01:00:00 0.4 0 0.7 0.4 0.4 0 0.7 0.4 0.4 0.2 1.5 0.4 33 49 360 165 15.6 0.3 16 15.2 07/02/2006 01:10:00 0.4 0.1 1.1 0.4 0.4 0.2 1.5 0.4 0.6 0.5 2.6 0.4 254 27 302 165 16.1 0.1 16.3 16 07/02/2006 01:20:00 0.4 0.2 1.1 0.4 0.4 0.2 1.5 0.4 0.8 0.5 2.3 0.4 293 76 291 165 16.3 0 16.6 16.3 07/02/2006 01:30:00 2.6 0.6 4.2 0.7 2.7 0.6 4.2 1.1 2.5 0.5 4.2 1.1 313 11 313 165 15.9 0 16.6 15.7 07/02/2006 01:40:00 3.1 0.4 4.6 2.3 3.3 0.4 4.9 2.3 2.9 0.4 3.8 1.9 312 8 304 165 15.4 0 15.7 15.2 07/02/2006 01:50:00 2.9 0.6 4.2 1.5 3 0.6 4.2 1.5 2.5 0.5 3.8 1.5 308 7 300 165 15.5 0 15.7 15.5 07/02/2006 02:00:00 1.9 0.8 3 0.4 2.1 0.8 3.4 0.4 2.1 0.6 3.4 0.4 302 7 297 165 15.7 0 16 15.7 07/02/2006 02:10:00 0.7 0.5 2.3 0.4 0.8 0.6 2.6 0.4 1.2 0.7 2.6 0.4 297 10 286 165 16 0.1 16.6 15.7 07/02/2006 02:20:00 0.4 0.2 1.5 0.4 0.5 0.4 1.9 0.4 0.7 0.6 2.6 0.4 283 13 273 165 16.3 0 16.6 16.3 07/02/2006 02:30:00 0.4 0.3 1.9 0.4 0.6 0.4 2.3 0.4 0.9 0.6 2.3 0.4 279 13 276 165 16.5 0.2 16.8 16.3 07/02/2006 02:40:00 0.7 0.4 1.9 0.4 0.9 0.5 1.9 0.4 1.3 0.7 2.6 0.4 273 23 205 165 16.8 0 17.1 16.8 07/02/2006 02:50:00 0.8 0.5 2.3 0.4 1 0.7 2.6 0.4 1.5 0.8 3 0.4 264 32 264 165 16.6 0 17.1 16.3 07/02/2006 03:00:00 1.3 0.8 3.8 0.4 1.5 0.9 3.8 0.4 2.1 0.9 4.2 0.4 290 23 291 165 16.6 0 16.8 16.3 07/02/2006 03:10:00 3.1 0.9 5.3 0.4 3.3 0.8 5.3 0.7 3.2 0.8 5.7 1.1 295 9 282 165 16.4 0 16.8 16.3 07/02/2006 03:20:00 3.2 0.7 4.9 1.5 3.4 0.7 4.9 1.9 3.3 0.8 5.7 1.9 300 9 292 165 16.3 0.1 16.6 16 07/02/2006 03:30:00 2.2 0.6 4.2 0.7 2.4 0.6 4.2 1.1 2.4 0.6 4.2 1.1 308 10 284 165 16.1 0 16.3 16 07/02/2006 03:40:00 2.2 0.8 4.2 0.4 2.4 0.7 4.2 0.7 2.4 0.7 4.2 0.7 300 13 287 165 16.2 0 16.3 16 07/02/2006 03:50:00 2.8 0.8 4.6 1.1 3 0.8 4.9 1.5 2.9 0.7 5.3 1.5 301 14 296 165 16.2 0 16.6 16 07/02/2006 04:00:00 2.9 0.7 4.2 0.7 3.1 0.7 4.6 0.7 3.1 0.6 4.6 1.9 300 11 304 165 16.2 0 16.6 16 07/02/2006 04:10:00 1.8 0.7 3.8 0.4 2.1 0.7 3.8 0.4 2.5 0.6 4.6 0.7 292 16 289 165 16.1 0 16.6 16 07/02/2006 04:20:00 2.4 0.9 4.2 0.4 2.6 0.9 4.6 0.7 2.8 0.7 4.6 1.5 292 12 295 165 16.2 0 16.6 16.3 07/02/2006 04:30:00 4.6 0.6 6.5 3 4.8 0.6 6.8 3 4.2 0.8 7.2 2.3 297 8 290 165 16.1 0 16.3 16 07/02/2006 04:40:00 5.5 0.6 6.8 3.8 5.6 0.6 6.8 3.8 4.4 0.8 6.5 2.6 296 6 297 165 16.2 0 16.6 16 07/02/2006 04:50:00 5.3 0.8 7.2 3.8 5.4 0.8 7.2 4.2 4.8 0.9 7.6 2.6 291 5 294 165 16.4 0 16.6 16.3 07/02/2006 05:00:00 5.5 0.8 6.8 3.4 5.6 0.8 7.6 3.8 4.8 1 7.2 2.3 290 6 278 165 16.5 0 16.8 16.3 07/02/2006 05:10:00 5.4 0.8 7.2 3.4 5.5 0.7 7.2 3.8 5 0.8 7.2 2.3 290 4 287 165 16.6 0 16.8 16.3 07/02/2006 05:20:00 5.1 0.6 6.5 3.8 5.2 0.6 6.8 4.2 4.2 0.7 6.5 2.6 292 4 287 165 16.6 0 16.8 16.3 07/02/2006 05:30:00 4.9 0.4 6.1 4.2 5 0.4 6.1 4.2 4.6 0.6 6.1 3 288 4 290 165 16.8 0.1 16.8 16.3 07/02/2006 05:40:00 4.3 0.4 5.3 3.4 4.4 0.4 5.3 3.4 4.1 0.5 5.3 2.3 288 4 289 165 16.8 0 17.1 16.6 07/02/2006 05:50:00 3.6 0.4 4.2 1.9 3.8 0.3 4.6 2.6 3.7 0.4 4.6 2.6 277 5 287 165 16.8 0 17.4 16.8 07/02/2006 06:00:00 2.8 0.5 3.8 1.5 3.4 0.2 3.8 3 3.5 0.2 4.2 3 271 4 272 165 16.7 0.2 17.1 16.3 07/02/2006 06:10:00 2.5 0.5 3.4 1.5 3.2 0.2 3.8 2.6 3.3 0.2 3.8 2.6 268 2 269 165 16.8 0.1 17.1 16.3 07/02/2006 06:20:00 3.1 0.2 3.4 2.6 3.3 0.2 3.8 3 3.4 0.2 3.8 3 276 4 273 165 17 0.1 17.4 16.8 07/02/2006 06:30:00 2.5 0.3 3 1.5 2.9 0.2 3.4 2.3 2.9 0.3 3.8 2.3 275 4 280 165 17.3 0 17.4 17.1 07/02/2006 06:40:00 2 0.4 2.6 0.7 2.5 0.3 3 1.9 2.5 0.2 3 1.9 269 5 270 165 17.6 0 17.7 17.4 07/02/2006 06:50:00 1.8 0.4 2.6 0.7 2.7 0.3 3.4 1.9 2.6 0.3 3.4 1.5 263 5 263 165 17.8 0 17.7 17.7 07/02/2006 07:00:00 1.4 0.4 2.3 0.7 2 0.3 3 1.5 2 0.3 2.6 1.5 251 8 255 165 18 0 18.2 17.7 07/02/2006 07:10:00 0.7 0.3 1.5 0.4 1.1 0.4 1.9 0.4 1.1 0.5 1.9 0.4 249 6 248 165 18.5 0.1 18.8 18.2 07/02/2006 07:20:00 0.6 0.3 1.5 0.4 1 0.3 1.9 0.4 1 0.3 1.5 0.4 248 10 248 165 19 0 19.1 18.5 07/02/2006 07:30:00 0.7 0.4 1.9 0.4 1 0.4 2.3 0.4 0.8 0.4 2.3 0.4 245 8 237 165 19.2 0.1 19.7 19.1 07/02/2006 07:40:00 0.4 0.2 1.1 0.4 0.6 0.3 1.5 0.4 0.4 0.2 1.5 0.4 277 8 284 165 20 0.1 20.2 19.7 07/02/2006 07:50:00 0.4 0.2 1.1 0.4 0.7 0.3 1.9 0.4 0.5 0.3 1.5 0.4 258 14 270 165 20.2 0 20.5 20 07/02/2006 08:00:00 0.4 0.1 0.7 0.4 0.5 0.2 1.1 0.4 0.5 0.2 1.5 0.4 256 0 256 165 20.5 0 20.8 20.5 07/02/2006 08:10:00 0.4 0.1 0.7 0.4 0.5 0.2 1.1 0.4 0.4 0.2 1.1 0.4 256 0 256 165 20.7 0.1 21.1 20.5 07/02/2006 08:20:00 0.5 0.2 1.5 0.4 0.6 0.4 1.9 0.4 0.4 0.2 1.1 0.4 261 11 270 165 21.2 0 21.4 20.8 07/02/2006 08:30:00 1.1 0.9 3.8 0.4 1.1 0.9 3.4 0.4 0.8 0.6 2.6 0.4 317 19 310 165 20.8 0 21.1 20.5 07/02/2006 08:40:00 0.6 0.4 1.9 0.4 0.5 0.3 1.5 0.4 0.5 0.3 1.5 0.4 52 45 335 165 20.1 0.1 20.8 19.7 07/02/2006 08:50:00 1 0.5 2.3 0.4 0.8 0.5 2.3 0.4 0.7 0.4 1.9 0.4 44 58 328 165 19.9 0.2 20.8 19.7 07/02/2006 09:00:00 1.2 0.4 2.3 0.4 0.9 0.5 1.9 0.4 0.9 0.4 1.9 0.4 336 16 359 165 20.8 0.3 21.4 20.2 07/02/2006 09:10:00 0.9 0.5 2.3 0.4 0.8 0.5 2.3 0.4 0.7 0.5 2.3 0.4 293 64 128 165 21 0.1 21.1 20.5 07/02/2006 09:20:00 0.7 0.4 1.9 0.4 0.5 0.3 1.9 0.4 0.9 0.4 1.9 0.4 142 11 133 165 19.7 0.4 20.8 19.4 07/02/2006 09:30:00 0.6 0.4 1.9 0.4 0.5 0.3 1.5 0.4 0.5 0.4 2.3 0.4 121 17 133 165 19.5 0.2 20.2 19.1 07/02/2006 09:40:00 0.8 0.4 1.9 0.4 0.6 0.3 1.9 0.4 0.7 0.4 1.9 0.4 157 86 347 165 20 0 20.2 19.7 07/02/2006 09:50:00 1.1 0.5 2.6 0.4 1 0.6 3 0.4 1.4 0.6 3 0.4 150 24 163 165 19.3 0.3 20 18.5 07/02/2006 10:00:00 1.3 0.7 2.6 0.4 1.3 0.8 2.6 0.4 1.5 0.8 3.4 0.4 163 49 141 165 19 0.1 19.4 18.5 07/02/2006 10:10:00 1.5 0.6 3 0.4 1.3 0.6 2.6 0.4 1.5 0.7 3 0.4 140 16 170 165 19 0 19.1 18.8 07/02/2006 10:20:00 1.4 0.6 2.6 0.4 1.3 0.6 2.6 0.4 1.6 0.6 3 0.4 135 17 150 165 18.5 0.1 18.8 18.2 07/02/2006 10:30:00 1.9 0.5 3.4 0.7 1.9 0.5 3 0.7 2.1 0.5 3.4 1.1 133 13 157 165 18.6 0 18.8 18.5 07/02/2006 10:40:00 1.6 0.6 3.4 0.4 1.7 0.6 3 0.4 1.8 0.6 3.8 0.4 130 18 154 165 18.5 0.2 19.1 18.2 07/02/2006 10:50:00 1.7 0.6 3 0.4 1.7 0.6 3.4 0.4 1.8 0.7 3.4 0.4 143 15 153 165 18.3 0 18.5 18 07/02/2006 11:00:00 1.4 0.7 3.4 0.4 1.4 0.7 3.4 0.4 1.6 0.7 3.4 0.4 143 13 135 165 18.5 0.1 18.8 18.2 07/02/2006 11:10:00 1.5 0.6 2.6 0.4 1.5 0.6 3 0.4 1.6 0.6 3 0.4 135 18 136 165 18.7 0.2 19.1 18.2 07/02/2006 11:20:00 1.8 0.5 3.4 0.7 1.9 0.5 3.4 0.7 2.1 0.5 3.8 0.4 136 13 137 165 18.2 0 18.5 18 07/02/2006 11:30:00 1.8 0.6 3 0.4 2 0.5 3.4 1.1 1.9 0.6 3.4 0.4 129 16 99 165 18.2 0.1 18.5 18 07/02/2006 11:40:00 2.4 0.6 4.2 0.7 2.5 0.6 4.2 1.1 2.6 0.6 4.2 0.7 141 13 156 165 18.1 0.1 18.5 17.7 07/02/2006 11:50:00 3.1 0.6 4.9 1.9 3.2 0.6 4.9 2.3 3.2 0.5 4.6 1.9 142 11 135 165 17.9 0 18.2 17.7 07/02/2006 12:00:00 2.5 0.6 4.2 1.5 2.7 0.5 4.2 1.9 2.7 0.6 4.9 1.5 132 12 137 165 17.6 0 18 17.4 07/02/2006 12:10:00 3 0.5 4.6 1.9 3.2 0.5 4.6 1.9 3.4 0.5 4.6 2.3 132 10 135 165 17.6 0.2 18 17.1 07/02/2006 12:20:00 2.7 0.5 4.2 1.5 2.8 0.5 4.2 1.9 3 0.5 4.6 1.9 133 10 122 165 17.1 0.2 17.7 16.8 07/02/2006 12:30:00 2.3 0.6 4.2 1.1 2.5 0.5 4.6 1.1 2.7 0.6 4.2 1.1 140 12 150 165 17.5 0 17.7 17.1 07/02/2006 12:40:00 2.5 0.4 3.8 1.5 2.7 0.4 4.2 1.5 2.7 0.5 4.2 1.1 128 12 131 165 17.7 0 18 17.4 07/02/2006 12:50:00 2.6 0.5 3.8 0.7 2.8 0.5 4.2 1.1 2.8 0.4 3.8 1.9 128 11 147 165 18 0 18.2 17.7 07/02/2006 13:00:00 2.8 0.6 4.2 1.1 3 0.5 4.2 1.5 3 0.5 4.2 1.1 133 15 122 165 18 0.1 18.2 17.4 07/02/2006 13:10:00 2.9 0.6 4.9 1.1 3.1 0.6 4.9 1.5 3.2 0.6 4.6 1.5 133 11 110 165 18.2 0.1 18.8 18 07/02/2006 13:20:00 3.4 0.7 5.7 1.5 3.6 0.6 5.7 1.9 3.7 0.6 5.3 1.9 134 11 134 165 19 0 19.4 18.5 07/02/2006 13:30:00 3.7 0.5 5.3 2.3 3.9 0.5 5.3 2.3 3.8 0.6 5.7 1.9 134 11 142 165 18.6 0.1 19.1 18.2 07/02/2006 13:40:00 3.7 0.6 5.3 2.3 3.9 0.6 5.3 1.9 3.9 0.6 5.3 2.3 129 10 127 165 18.7 0.1 19.1 18.2 07/02/2006 13:50:00 4.5 0.6 6.5 2.6 4.6 0.6 6.5 3 4.7 0.6 6.8 3 129 8 139 165 18.7 0 18.8 18.2 07/02/2006 14:00:00 4 0.5 5.3 2.6 4.1 0.5 5.7 2.6 4.3 0.6 5.7 3 132 7 121 165 18.2 0 18.5 18 07/02/2006 14:10:00 3.3 0.5 5.3 1.9 3.3 0.5 4.9 1.9 3.4 0.5 4.9 1.9 132 10 121 165 18.5 0.1 18.8 18 07/02/2006 14:20:00 3.2 0.5 4.6 1.9 3.2 0.5 4.6 1.9 3.4 0.7 5.3 1.1 128 9 117 165 18.7 0 18.8 18.2 07/02/2006 14:30:00 3.2 0.6 4.9 1.5 3.2 0.6 4.9 1.9 3.3 0.6 4.9 1.5 130 11 125 165 19 0.2 19.4 18.2 07/02/2006 14:40:00 2.9 0.5 4.6 1.5 2.9 0.5 4.6 1.5 3 0.5 4.6 1.9 133 17 154 165 19.2 0.1 19.4 18.8 07/02/2006 14:50:00 2.8 0.5 4.2 1.5 2.8 0.5 4.2 1.5 2.9 0.5 4.6 1.9 130 15 125 165 19.3 0 19.4 19.1 07/02/2006 15:00:00 2.8 0.4 4.2 1.5 2.8 0.5 4.2 1.5 3 0.5 4.2 1.9 133 9 142 165 19.4 0 19.7 19.1 07/02/2006 15:10:00 2.3 0.5 3.8 1.1 2.3 0.5 4.2 1.1 2.5 0.4 3.8 1.5 139 10 139 165 19.5 0 20 19.4 07/02/2006 15:20:00 2.6 0.5 3.8 1.1 2.7 0.5 3.8 1.5 2.9 0.5 4.6 1.9 136 11 136 165 19.7 0 20 19.4 07/02/2006 15:30:00 2.4 0.5 3.4 1.1 2.5 0.5 3.8 1.1 2.7 0.5 3.8 1.5 135 10 143 165 19.7 0 20 19.7 07/02/2006 15:40:00 2.2 0.5 3.8 0.7 2.4 0.6 4.2 0.7 2.5 0.5 3.8 1.1 137 10 126 165 20.1 0 20.5 19.7 07/02/2006 15:50:00 2.5 0.4 3.4 1.5 2.7 0.4 4.2 1.5 2.8 0.4 4.2 1.9 129 11 130 165 20 0 20.5 19.7 07/02/2006 16:00:00 2.4 0.5 3.8 1.5 2.6 0.4 4.2 1.5 2.7 0.4 3.8 1.5 130 11 147 165 20.2 0 20.5 20 07/02/2006 16:10:00 2.5 0.4 3.4 1.1 2.7 0.3 3.4 1.5 2.7 0.3 3.4 1.9 122 7 137 165 19.8 0 20.5 19.7 07/02/2006 16:20:00 2.2 0.5 3.4 1.1 2.5 0.4 3.8 1.1 2.6 0.4 3.8 1.1 122 11 147 165 20.2 0 21.1 20 07/02/2006 16:30:00 2.2 0.5 3.8 1.1 2.5 0.4 3.8 1.5 2.5 0.5 3.8 1.1 122 9 140 165 20.2 0.1 20.8 20 07/02/2006 16:40:00 1.9 0.5 3.4 0.4 2.3 0.5 3.8 1.1 2.3 0.4 3.4 1.1 115 13 133 165 20.2 0 20.5 20 07/02/2006 16:50:00 2 0.6 3.4 0.4 2.4 0.5 3.4 1.1 2.5 0.4 3.8 1.1 117 11 115 165 20 0 20.5 20 07/02/2006 17:00:00 2.3 0.5 3.4 0.7 2.6 0.4 3.4 1.5 2.3 0.5 3.4 0.7 114 9 128 165 20 0 20.2 19.7 07/02/2006 17:10:00 2.1 0.8 3.8 0.4 2.5 0.6 3.8 0.7 2.4 0.6 3.4 0.4 106 13 93 165 20 0 20.2 19.7 07/02/2006 17:20:00 2 0.6 3 0.4 2.4 0.5 3.4 0.7 2.4 0.5 3.4 0.4 114 17 107 165 20.2 0 20.5 20 07/02/2006 17:30:00 1.1 0.6 2.6 0.4 1.7 0.5 2.6 0.4 1.7 0.5 3 0.7 126 15 118 165 20.2 0 20.5 20 07/02/2006 17:40:00 1.3 0.6 2.6 0.4 1.9 0.6 3 0.4 1.9 0.5 3 0.4 117 10 111 165 20 0 20.2 20 07/02/2006 17:50:00 1 0.5 2.3 0.4 1.6 0.5 2.6 0.4 1.4 0.5 2.6 0.4 130 18 112 165 19.9 0 20 19.7 07/02/2006 18:00:00 1.5 0.5 2.3 0.4 1.9 0.5 2.6 0.4 1.7 0.5 2.6 0.4 117 13 130 165 20 0 20.2 19.7 07/02/2006 18:10:00 0.6 0.3 1.9 0.4 1.2 0.4 2.3 0.4 0.9 0.5 1.9 0.4 107 16 89 165 20 0 20.2 19.7 07/02/2006 18:20:00 0.8 0.4 1.9 0.4 1.5 0.4 2.3 0.4 1.1 0.4 1.9 0.4 108 8 111 165 20 0 20.2 20 07/02/2006 18:30:00 0.4 0.2 1.5 0.4 0.9 0.5 1.9 0.4 0.6 0.3 1.9 0.4 103 1 102 165 19.9 0 20 19.7 07/02/2006 18:40:00 1.1 0.6 2.3 0.4 1.5 0.7 2.6 0.4 1.1 0.6 2.3 0.4 114 6 113 165 19.7 0.1 20 19.4 07/02/2006 18:50:00 1.1 0.4 1.9 0.4 1.7 0.3 2.3 1.1 1.6 0.4 2.3 0.7 107 2 105 165 19.3 0 19.7 19.1 07/02/2006 19:00:00 0.5 0.4 2.3 0.4 1.2 0.4 2.6 0.4 1 0.3 2.3 0.4 89 17 63 165 19.5 0.1 19.7 19.4 07/02/2006 19:10:00 0.9 0.6 2.6 0.4 1.4 0.6 2.6 0.4 1.2 0.6 2.6 0.4 59 22 37 165 19.5 0 19.7 19.4 07/02/2006 19:20:00 0.7 0.5 2.6 0.4 1.2 0.6 2.6 0.4 0.9 0.5 2.3 0.4 77 18 83 165 19.5 0.1 20 19.4 07/02/2006 19:30:00 0.5 0.2 1.5 0.4 1.1 0.4 1.9 0.4 0.9 0.4 1.5 0.4 83 12 94 165 19.7 0.1 20 19.4 07/02/2006 19:40:00 0.4 0 0.4 0.4 0.8 0.3 1.5 0.4 0.7 0.3 1.5 0.4 94 5 165 165 19.5 0 19.7 19.4 07/02/2006 19:50:00 0.4 0 0.4 0.4 0.9 0.4 1.5 0.4 1 0.4 1.9 0.4 95 0 165 165 19.2 0.1 19.4 18.8 07/02/2006 20:00:00 0.5 0.3 1.9 0.4 0.8 0.4 1.9 0.4 0.7 0.4 2.3 0.4 35 45 29 165 19.1 0 19.4 18.8 07/02/2006 20:10:00 0.5 0.3 1.5 0.4 0.8 0.3 1.5 0.4 0.6 0.3 1.5 0.4 350 15 350 165 19.6 0 20 19.4 07/02/2006 20:20:00 0.7 0.4 1.5 0.4 1 0.4 1.9 0.4 1.3 0.4 1.9 0.4 344 11 325 165 19.7 0 20 19.7 07/02/2006 20:30:00 0.4 0 0.4 0.4 0.4 0.1 1.1 0.4 0.7 0.3 1.5 0.4 353 4 165 165 19.7 0 20 19.7 07/02/2006 20:40:00 0.4 0 0.7 0.4 0.4 0.1 1.1 0.4 0.5 0.2 1.9 0.4 338 0 338 165 19.5 0 19.7 19.4 07/02/2006 20:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 338 1 165 165 19.5 0 19.7 19.4 07/02/2006 21:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 338 1 165 165 19.1 0.2 19.7 18.5 07/02/2006 21:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 338 1 165 165 18.4 0 18.8 18 07/02/2006 21:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 320 45 165 165 17.5 0.3 18.2 17.1 07/02/2006 21:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 208 1 165 165 16.8 0.1 17.1 16.8 07/02/2006 21:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 208 1 165 165 16.8 0 16.8 16.6 07/02/2006 21:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 209 1 165 165 16.8 0 16.8 16.8 07/02/2006 22:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 208 1 165 165 16.8 0 16.8 16.8 07/02/2006 22:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 208 2 165 165 16.5 0 16.8 16.6 07/02/2006 22:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0.2 0.7 0.4 208 2 165 165 16.5 0 16.8 16.6 07/02/2006 22:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 208 2 165 165 16.8 0 16.8 16.6 07/02/2006 22:40:00 0.4 0.1 1.1 0.4 0.7 0.3 1.5 0.4 0.7 0.3 1.5 0.4 247 27 236 165 16.6 0 16.8 16.3 07/02/2006 22:50:00 0.4 0.2 1.1 0.4 1 0.2 1.5 0.4 0.7 0.2 1.5 0.4 279 2 281 165 16.4 0 16.8 16 07/02/2006 23:00:00 1.3 0.4 2.3 0.4 1.6 0.3 2.3 0.7 1.5 0.4 2.3 0.4 281 3 287 165 16.6 0.2 16.8 16.3 07/02/2006 23:10:00 1.2 0.5 2.6 0.4 1.5 0.5 3 0.4 1.2 0.3 2.3 0.4 305 9 294 165 16.4 0.1 16.8 16 07/02/2006 23:20:00 1.8 0.7 3 0.4 2 0.6 3.4 0.4 1.4 0.5 2.6 0.4 303 11 298 165 16.4 0.1 16.8 16 07/02/2006 23:30:00 1.1 0.9 2.6 0.4 1.3 1 3 0.4 1.3 0.6 2.6 0.4 298 6 290 165 16.4 0 16.8 16 07/02/2006 23:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0.1 1.1 0.4 30 1 165 165 16.8 0 17.1 16.6 07/02/2006 23:50:00 0.5 0.3 1.5 0.4 0.5 0.3 1.5 0.4 0.6 0.3 1.5 0.4 341 28 315 165 16.8 0 17.1 16.6 07/03/2006 00:00:00 0.6 0.4 1.5 0.4 0.8 0.4 1.9 0.4 0.9 0.5 2.3 0.4 307 8 326 165 16.6 0 17.1 16.3 07/03/2006 00:10:00 1.1 0.5 1.9 0.4 0.9 0.4 1.9 0.4 1.1 0.4 1.9 0.4 343 22 358 165 16.9 0 17.1 16.6 07/03/2006 00:20:00 0.8 0.5 1.9 0.4 0.4 0.2 1.1 0.4 0.8 0.4 1.9 0.4 1 1 1 165 16.5 0.1 17.1 16 07/03/2006 00:30:00 0.4 0 0.7 0.4 0.4 0.2 1.1 0.4 0.6 0.3 1.1 0.4 50 41 98 165 16.5 0.2 16.8 16 07/03/2006 00:40:00 0.4 0.1 0.7 0.4 0.5 0.2 1.1 0.4 0.7 0.3 1.1 0.4 99 3 98 165 16.6 0.2 17.1 16.3 07/03/2006 00:50:00 0.5 0.4 1.5 0.4 0.7 0.4 1.5 0.4 0.8 0.4 1.9 0.4 126 7 136 165 16.3 0.2 16.8 15.7 07/03/2006 01:00:00 0.7 0.5 1.9 0.4 0.7 0.5 1.9 0.4 1.1 0.3 1.9 0.4 150 3 147 165 16.3 0.1 16.8 15.7 07/03/2006 01:10:00 1 0.4 1.9 0.4 1.2 0.4 2.3 0.4 1.3 0.4 1.9 0.4 155 6 158 165 16.4 0 16.6 16 07/03/2006 01:20:00 0.7 0.2 1.1 0.4 1 0.2 1.5 0.4 1 0.2 1.5 0.4 142 0 143 165 16.5 0 16.8 16 07/03/2006 01:30:00 0.4 0 0.4 0.4 1.2 0.2 1.5 0.7 1.3 0.2 1.9 0.7 142 0 165 165 16.4 0 16.6 16 07/03/2006 01:40:00 0.4 0 0.4 0.4 0.8 0.4 1.5 0.4 1 0.4 1.5 0.4 142 0 165 165 16.4 0 16.6 16 07/03/2006 01:50:00 0.6 0.4 2.3 0.4 0.7 0.5 2.3 0.4 1 0.6 2.3 0.4 220 51 280 165 16.4 0.2 16.8 16 07/03/2006 02:00:00 1.5 0.7 2.6 0.4 1.7 0.7 3 0.4 1.9 0.6 3 0.4 285 7 282 165 16.6 0.1 16.8 15.7 07/03/2006 02:10:00 2.1 0.6 3.4 0.4 2.3 0.5 3.4 1.1 2.3 0.5 3.4 0.7 285 9 285 165 16.3 0 16.6 16 07/03/2006 02:20:00 2.9 0.5 4.2 1.5 3.2 0.5 4.2 1.9 3 0.5 4.6 1.9 279 5 281 165 16.5 0 16.8 16 07/03/2006 02:30:00 3.7 0.4 4.6 2.3 3.9 0.4 4.9 2.6 4.1 0.5 4.9 2.3 279 6 282 165 16.3 0 16.6 15.7 07/03/2006 02:40:00 3.8 0.6 5.3 1.9 3.9 0.6 5.7 2.3 3.7 0.6 5.3 1.9 282 5 282 165 16.3 0.2 16.8 15.7 07/03/2006 02:50:00 2.5 0.8 4.2 0.4 2.7 0.7 4.6 1.1 2.6 0.8 4.2 0.4 279 9 286 165 16.4 0 16.6 16 07/03/2006 03:00:00 2.2 0.3 3 1.1 2.4 0.3 3 1.5 1.8 0.3 2.6 1.1 295 7 295 165 16.1 0 16.6 16 07/03/2006 03:10:00 1.4 0.5 2.6 0.4 1.6 0.5 2.6 0.4 1.7 0.3 2.3 0.7 309 9 282 165 15.7 0.2 16.3 15.2 07/03/2006 03:20:00 0.9 0.5 1.9 0.4 1 0.6 2.3 0.4 1.1 0.5 2.3 0.4 312 10 309 165 15.4 0.1 15.7 15.2 07/03/2006 03:30:00 0.4 0.1 0.7 0.4 0.4 0.1 0.7 0.4 0.5 0.3 1.5 0.4 303 4 309 165 16.1 0.2 16.6 15.7 07/03/2006 03:40:00 1.3 0.8 3 0.4 1.4 0.9 3.4 0.4 1.4 0.7 2.6 0.4 289 16 304 165 16.4 0 16.6 16.3 07/03/2006 03:50:00 2.6 0.3 3.4 1.9 2.8 0.3 3.4 2.3 2.5 0.5 3.4 1.5 287 8 291 165 16.3 0 16.6 16.3 07/03/2006 04:00:00 2.4 0.5 3.4 0.7 2.7 0.5 3.8 1.1 2.6 0.5 3.8 1.1 276 7 272 165 16.4 0 16.6 16.3 07/03/2006 04:10:00 2.6 0.4 3.8 1.5 2.8 0.4 3.8 1.9 2.7 0.4 3.8 1.5 280 6 284 165 16.2 0 16.6 16 07/03/2006 04:20:00 2.7 0.6 3.8 1.1 2.9 0.6 4.2 1.5 2.6 0.5 3.8 1.5 282 7 280 165 16.1 0 16.3 16 07/03/2006 04:30:00 2.8 0.6 4.2 1.1 3.1 0.6 4.2 1.9 2.8 0.5 3.8 1.5 274 6 279 165 16.2 0 16.6 16.3 07/03/2006 04:40:00 3.1 0.6 4.2 0.7 3.4 0.5 4.2 1.9 3 0.4 4.2 1.9 276 6 282 165 15.8 0.1 16.3 15.7 07/03/2006 04:50:00 2.4 0.6 3.8 0.7 3.1 0.5 4.2 1.5 2.7 0.4 3.8 1.9 270 7 273 165 16.2 0.1 16.6 16 07/03/2006 05:00:00 2.1 0.5 3.4 0.7 2.5 0.5 3.8 1.1 1.9 0.5 3 0.4 277 12 272 165 16.4 0 16.6 16.3 07/03/2006 05:10:00 2.4 0.6 3.4 0.7 2.7 0.5 3.8 1.1 2.4 0.5 3.4 0.7 280 7 280 165 16.3 0 16.8 16 07/03/2006 05:20:00 2.2 0.4 3.4 1.1 2.5 0.4 3.8 1.5 1.9 0.5 3 0.7 285 6 285 165 16.6 0.1 16.8 16 07/03/2006 05:30:00 1.7 0.5 3.4 0.7 2 0.5 3.4 1.1 1.5 0.6 3.4 0.4 290 8 279 165 16.4 0.3 17.1 16 07/03/2006 05:40:00 1.3 0.3 2.3 0.4 1.5 0.3 2.3 0.7 1.3 0.4 2.3 0.7 299 13 282 165 15.4 0.3 16.3 14.6 07/03/2006 05:50:00 0.9 0.5 2.3 0.4 1.1 0.5 2.6 0.4 1.7 0.3 2.3 1.1 326 11 313 165 14.7 0 15.2 14.4 07/03/2006 06:00:00 0.7 0.5 1.9 0.4 0.6 0.4 2.3 0.4 1.4 0.7 2.6 0.4 340 18 9 165 14.3 0.4 14.9 13.3 07/03/2006 06:10:00 0.4 0.2 1.1 0.4 0.4 0.1 1.1 0.4 0.9 0.6 2.3 0.4 26 58 114 165 13.7 0.1 14.1 13.3 07/03/2006 06:20:00 0.7 0.6 2.3 0.4 0.7 0.6 2.6 0.4 2 0.6 3 0.4 347 30 338 165 13.2 0.3 13.8 12.5 07/03/2006 06:30:00 1 0.7 2.6 0.4 1.1 0.8 3 0.4 2.1 0.5 3 0.4 323 18 348 165 12.3 0.3 13 11.7 07/03/2006 06:40:00 1.2 0.7 2.6 0.4 1 0.6 2.6 0.4 2.1 0.5 3 0.7 352 19 353 165 11.7 0 11.9 11.7 07/03/2006 06:50:00 2.5 0.6 3.4 0.7 2.5 0.7 3.8 0.7 3 0.5 3.8 1.9 346 7 338 165 11.3 0.1 11.9 11.1 07/03/2006 07:00:00 2.8 0.5 3.8 1.1 2.7 0.6 3.8 0.7 3.3 0.4 4.2 2.6 341 12 352 165 10.7 0.1 11.1 10.3 07/03/2006 07:10:00 2 0.8 3.4 0.4 2.3 0.8 3.4 0.4 2.8 0.3 3.4 2.3 328 7 338 165 10.5 0 10.9 10.1 07/03/2006 07:20:00 0.9 0.7 2.6 0.4 1 0.8 2.6 0.4 2.4 0.3 3 1.1 325 15 334 165 10.1 0.1 10.6 9.6 07/03/2006 07:30:00 0.5 0.4 2.3 0.4 0.6 0.5 2.3 0.4 1.3 0.8 2.6 0.4 323 17 342 165 10.1 0.1 10.3 9.6 07/03/2006 07:40:00 0.4 0 0.7 0.4 0.4 0 0.7 0.4 1.3 0.7 2.3 0.4 297 53 320 165 10.2 0 10.3 10.1 07/03/2006 07:50:00 0.6 0.3 1.5 0.4 0.8 0.5 1.9 0.4 1.4 0.4 2.3 0.4 271 15 244 165 10.2 0 10.6 10.1 07/03/2006 08:00:00 0.4 0.1 1.1 0.4 0.4 0.2 1.5 0.4 1.6 0.6 2.6 0.4 323 0 325 165 10.5 0 10.9 10.3 07/03/2006 08:10:00 1.6 0.8 3 0.4 1.4 0.7 3 0.4 2.3 0.9 3.4 0.4 354 17 4 165 10.5 0 10.9 10.3 07/03/2006 08:20:00 0.4 0.2 1.1 0.4 0.4 0.2 1.9 0.4 2.2 0.4 3 1.1 338 11 335 165 10.4 0 10.9 10.3 07/03/2006 08:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.5 0.4 2.3 0.4 343 26 165 165 10.9 0.2 11.7 10.6 07/03/2006 08:40:00 0.5 0.3 1.5 0.4 0.9 0.4 1.9 0.4 0.9 0.5 2.3 0.4 240 18 217 165 12.5 0.3 12.7 11.7 07/03/2006 08:50:00 1.2 0.8 2.6 0.4 1.1 0.7 2.6 0.4 1.8 0.8 3 0.4 324 47 3 165 12.4 0.2 13 11.9 07/03/2006 09:00:00 0.4 0.2 1.5 0.4 0.4 0.2 1.5 0.4 0.9 0.5 2.3 0.4 3 13 15 165 11.9 0 12.5 11.7 07/03/2006 09:10:00 1.2 0.7 2.6 0.4 1.3 0.7 2.6 0.4 2 0.5 3 0.4 13 16 359 165 11.9 0 12.2 11.9 07/03/2006 09:20:00 2.6 0.4 3.4 1.9 2.3 0.5 3.4 1.1 2.7 0.4 3.8 1.5 16 11 349 165 11.9 0.1 12.2 11.9 07/03/2006 09:30:00 2.1 0.5 3.4 0.7 2.1 0.5 3.4 0.7 2.5 0.4 3.8 1.5 24 15 7 165 12.2 0.1 12.5 11.9 07/03/2006 09:40:00 2.3 0.4 3.4 1.1 2.3 0.5 3.4 0.7 2.8 0.4 3.8 1.9 19 11 14 165 12.6 0 13 12.5 07/03/2006 09:50:00 2.1 0.6 3.8 0.7 2.2 0.6 3.8 0.7 2.6 0.5 4.2 1.5 20 10 9 165 13.3 0.2 13.5 12.7 07/03/2006 10:00:00 2 0.4 3 0.4 1.9 0.4 3 0.7 2.6 0.4 3.8 1.5 10 10 11 165 13.7 0.2 14.1 13.3 07/03/2006 10:10:00 1.9 0.7 3.4 0.4 1.7 0.6 3.4 0.4 2.2 0.7 3.4 0.4 10 10 16 165 14.2 0.2 14.6 13.5 07/03/2006 10:20:00 1.2 0.8 3.4 0.4 1.2 0.7 3.4 0.4 1.3 0.6 3.4 0.4 7 19 347 165 14.4 0.1 14.9 14.1 07/03/2006 10:30:00 2.2 0.5 3.4 1.1 2 0.5 3 0.7 2.2 0.5 3.4 0.7 2 12 26 165 14.4 0.1 14.9 14.1 07/03/2006 10:40:00 1.4 0.6 3 0.4 1.3 0.5 2.6 0.4 1.6 0.5 2.6 0.4 11 15 357 165 14.4 0 14.6 14.1 07/03/2006 10:50:00 1.1 0.7 3 0.4 1.1 0.7 3 0.4 1.3 0.8 3 0.4 4 20 343 165 14.9 0.2 15.2 14.1 07/03/2006 11:00:00 1.2 0.7 3 0.4 1.3 0.6 3 0.4 1.3 0.7 3 0.4 12 24 16 165 14.9 0 15.2 14.6 07/03/2006 11:10:00 0.5 0.3 1.9 0.4 0.7 0.4 2.3 0.4 0.9 0.5 2.6 0.4 314 90 343 165 14.4 0.2 14.9 13.8 07/03/2006 11:20:00 1.3 0.7 3 0.4 1.5 0.6 3 0.4 1.6 0.8 3 0.4 14 17 7 165 14.4 0 14.6 14.1 07/03/2006 11:30:00 0.9 0.8 3 0.4 1.1 0.8 3.4 0.4 1 0.6 2.6 0.4 92 76 25 165 14.2 0 14.4 13.8 07/03/2006 11:40:00 0.8 0.6 2.3 0.4 0.9 0.6 2.6 0.4 0.8 0.6 2.3 0.4 356 79 10 165 13.7 0.1 14.1 13.5 07/03/2006 11:50:00 0.9 0.9 3.4 0.4 1 0.8 3.4 0.4 1.1 1 3.8 0.4 345 86 6 165 13.9 0 14.1 13.5 07/03/2006 12:00:00 1.8 0.8 3.4 0.4 1.8 0.7 3.4 0.4 2 1 3.8 0.4 15 28 15 165 14 0.2 14.6 13.5 07/03/2006 12:10:00 1.3 0.5 3 0.4 1.4 0.5 2.6 0.4 1.8 0.5 3 0.4 3 13 0 165 14.7 0.3 15.2 14.1 07/03/2006 12:20:00 0.9 0.5 2.3 0.4 1.2 0.5 3 0.4 1.1 0.5 2.3 0.4 48 49 359 165 14.8 0.4 15.5 14.1 07/03/2006 12:30:00 0.9 0.6 3 0.4 0.9 0.6 3 0.4 0.8 0.5 2.3 0.4 13 56 341 165 14.2 0.1 14.6 13.8 07/03/2006 12:40:00 1.3 0.6 2.6 0.4 1.5 0.7 3 0.4 1.5 0.6 3 0.4 98 86 33 165 14.1 0.4 14.9 13.3 07/03/2006 12:50:00 1.7 0.7 3.4 0.4 2.1 0.6 3.8 0.7 2.1 0.7 3.4 0.4 72 29 32 165 13 0.1 13.3 12.7 07/03/2006 13:00:00 1.3 0.6 3.4 0.4 1.8 0.6 3.4 0.4 1.8 0.7 3.4 0.4 92 19 90 165 12.7 0.6 13.3 11.7 07/03/2006 13:10:00 1.3 0.6 3 0.4 1.8 0.5 3 0.4 1.9 0.5 3 0.4 100 20 122 165 12 0 12.2 11.7 07/03/2006 13:20:00 1.3 0.7 3 0.4 1.8 0.7 3.4 0.4 2 0.7 3.8 0.4 99 17 107 165 11.5 0.2 12.2 11.1 07/03/2006 13:30:00 2.1 0.5 3.4 0.4 2.5 0.4 3.8 1.5 2.6 0.4 3.4 1.5 102 9 114 165 11.1 0.1 11.4 10.6 07/03/2006 13:40:00 2.5 0.5 3.8 1.1 2.9 0.5 4.2 1.5 3 0.5 4.2 1.9 108 9 119 165 11.1 0 11.1 10.9 07/03/2006 13:50:00 2.7 0.5 4.2 1.1 3.1 0.5 4.2 1.9 3 0.4 4.2 1.9 112 8 112 165 11.1 0 11.4 10.9 07/03/2006 14:00:00 2.8 0.4 4.2 1.5 3.1 0.4 4.6 2.3 3 0.4 3.8 1.9 113 7 109 165 10.8 0.1 11.1 10.6 07/03/2006 14:10:00 3.3 0.4 4.6 1.9 3.6 0.4 4.6 2.3 3.6 0.4 4.6 2.6 114 7 117 165 10.8 0 11.1 10.6 07/03/2006 14:20:00 2.7 0.4 3.8 1.5 3.1 0.4 4.2 2.3 3.1 0.4 4.2 2.3 118 7 119 165 10.8 0.1 11.1 10.6 07/03/2006 14:30:00 2.3 0.4 3.4 1.1 2.8 0.4 3.8 1.5 2.8 0.4 3.8 1.9 115 8 114 165 10.9 0 11.1 10.6 07/03/2006 14:40:00 1.9 0.6 3 0.4 2.4 0.4 3.4 1.5 2.3 0.4 3.4 1.1 109 11 130 165 11.1 0.1 11.4 10.9 07/03/2006 14:50:00 1.8 0.5 3 0.4 2.4 0.4 3.4 1.1 2.4 0.4 3.8 1.5 117 13 101 165 11 0.2 11.4 10.6 07/03/2006 15:00:00 1.7 0.4 2.6 0.7 2.2 0.4 3 1.5 2.3 0.5 3.4 1.1 130 10 139 165 10.9 0 11.1 10.6 07/03/2006 15:10:00 2 0.7 3.8 0.4 2.5 0.6 4.2 1.1 2.4 0.5 4.2 1.1 126 15 105 165 10.7 0.1 11.1 10.3 07/03/2006 15:20:00 1.9 0.6 3.8 0.4 2.4 0.5 4.2 1.1 2.4 0.4 3.8 1.5 137 16 119 165 10.6 0.1 11.4 10.3 07/03/2006 15:30:00 1.1 0.6 2.3 0.4 1.8 0.5 2.6 0.4 1.8 0.4 3 0.7 139 13 153 165 10.5 0.2 10.9 9.8 07/03/2006 15:40:00 1.1 0.6 2.3 0.4 1.7 0.5 2.6 0.4 1.8 0.5 2.6 0.4 141 16 114 165 10.5 0.1 10.9 10.1 07/03/2006 15:50:00 1.5 0.5 3 0.4 2 0.4 3.4 1.1 2.2 0.4 3 1.5 147 11 128 165 10.4 0.1 10.9 9.8 07/03/2006 16:00:00 1.9 0.5 3 0.7 2.3 0.4 3.4 1.5 2.6 0.4 3.4 1.9 152 7 157 165 10.1 0.1 10.6 9.6 07/03/2006 16:10:00 1.8 0.5 3 0.4 2.2 0.4 3.4 1.1 2.3 0.4 3.4 1.1 138 9 148 165 10.2 0 10.6 9.6 07/03/2006 16:20:00 1.5 0.4 2.3 0.4 2 0.4 3 0.7 2.1 0.4 3 1.1 131 9 138 165 10.1 0.1 10.6 9.6 07/03/2006 16:30:00 2.2 0.6 3.8 1.1 2.6 0.5 3.8 1.9 2.7 0.5 3.8 1.1 135 12 132 165 10.1 0.1 10.6 9.6 07/03/2006 16:40:00 2.5 0.4 3.4 1.5 2.8 0.4 3.8 1.9 2.9 0.4 3.8 1.9 138 7 151 165 10 0 10.3 9.8 07/03/2006 16:50:00 2.4 0.4 3.8 1.5 2.7 0.4 3.8 1.9 2.8 0.4 3.8 1.9 140 7 145 165 10.1 0 10.3 9.8 07/03/2006 17:00:00 2.2 0.5 3 0.7 2.6 0.4 3.4 1.5 2.7 0.4 3.4 1.5 137 8 152 165 10 0 10.3 9.8 07/03/2006 17:10:00 2.1 0.5 3.4 0.7 2.4 0.4 3.8 1.1 2.5 0.4 3.4 1.5 144 9 140 165 10.1 0 10.6 10.1 07/03/2006 17:20:00 1.9 0.4 3 0.7 2.2 0.4 3 1.1 2.3 0.4 3.4 1.5 132 8 138 165 10.2 0 10.3 10.1 07/03/2006 17:30:00 1.4 0.5 2.6 0.4 1.8 0.4 2.6 1.1 1.9 0.4 3 0.7 134 14 163 165 10.4 0 10.9 10.3 07/03/2006 17:40:00 1.9 0.5 3 0.7 2.2 0.4 3.4 1.1 2.4 0.4 3 1.5 146 10 147 165 10.2 0.1 10.6 10.1 07/03/2006 17:50:00 2.4 0.4 3.4 1.5 2.7 0.4 3.8 1.5 2.8 0.4 3.8 1.5 145 7 148 165 10.1 0 10.6 9.8 07/03/2006 18:00:00 1.8 0.5 3 0.4 2.2 0.4 3 1.1 2.4 0.3 3 1.5 147 10 152 165 9.8 0 10.1 9.6 07/03/2006 18:10:00 2.1 0.4 3 1.1 2.4 0.3 3.8 1.9 2.6 0.4 4.2 1.9 138 10 126 165 9.9 0 10.1 9.8 07/03/2006 18:20:00 1.8 0.5 3 0.7 2.2 0.4 3 1.5 2.3 0.4 3.8 1.5 133 8 129 165 9.8 0.1 10.3 9.6 07/03/2006 18:30:00 1.4 0.5 2.6 0.4 1.9 0.4 3 0.7 2 0.4 3 1.1 127 13 139 165 9.7 0 9.8 9.6 07/03/2006 18:40:00 0.9 0.4 1.9 0.4 1.5 0.4 2.6 0.4 1.6 0.4 2.3 0.4 130 10 127 165 10 0 10.1 9.8 07/03/2006 18:50:00 0.6 0.5 2.3 0.4 0.9 0.6 2.3 0.4 1.1 0.7 2.6 0.4 107 33 125 165 10.1 0 10.3 9.8 07/03/2006 19:00:00 0.6 0.3 1.5 0.4 0.8 0.5 2.3 0.4 1 0.6 2.3 0.4 118 13 111 165 10.1 0 10.3 9.8 07/03/2006 19:10:00 1.2 0.4 1.9 0.4 1.7 0.3 2.6 0.7 1.8 0.3 2.6 1.1 136 10 134 165 10.1 0.1 10.3 9.8 07/03/2006 19:20:00 0.9 0.4 2.3 0.4 1.3 0.4 2.3 0.4 1.6 0.4 2.3 0.7 129 11 147 165 10 0 10.3 9.6 07/03/2006 19:30:00 1.7 0.5 2.6 0.4 2.1 0.4 3 1.1 2.2 0.4 3 1.1 139 9 145 165 9.8 0 10.1 9.3 07/03/2006 19:40:00 2.2 0.4 3 1.1 2.6 0.4 3.4 1.9 2.6 0.4 3.4 1.9 128 12 142 165 9.6 0.1 9.8 9 07/03/2006 19:50:00 2 0.4 3 1.1 2.4 0.3 3 1.5 2.5 0.3 3.4 1.5 132 6 130 165 9.6 0 9.8 9.6 07/03/2006 20:00:00 2.5 0.4 3.4 1.5 2.8 0.4 3.8 1.9 2.9 0.4 3.8 1.9 138 7 139 165 9.6 0 9.8 9.6 07/03/2006 20:10:00 2.5 0.5 3.4 1.1 2.7 0.4 3.8 1.9 2.8 0.4 3.8 1.9 137 6 125 165 9.5 0 9.6 9.3 07/03/2006 20:20:00 2.9 0.4 3.8 2.3 3.2 0.4 4.2 2.3 3.2 0.4 4.2 2.3 138 7 136 165 9.3 0 9.6 9 07/03/2006 20:30:00 2.9 0.7 4.9 1.1 3.1 0.6 4.9 1.1 3.1 0.7 4.9 1.9 135 11 133 165 9.2 0 9.6 8.8 07/03/2006 20:40:00 3 0.4 4.2 1.9 3.2 0.4 4.6 1.9 3.3 0.5 4.6 1.5 146 6 141 165 9.2 0 9.3 8.8 07/03/2006 20:50:00 3.1 0.4 4.2 1.9 3.2 0.4 4.2 1.9 3.3 0.4 4.2 2.3 143 7 143 165 9 0.1 9.6 8.5 07/03/2006 21:00:00 2.4 0.4 3.8 1.5 2.7 0.4 3.8 1.9 2.7 0.5 3.8 1.5 121 10 130 165 8.9 0.2 9.3 8.5 07/03/2006 21:10:00 2.4 0.6 4.2 1.5 2.7 0.7 4.2 1.5 2.8 0.6 4.2 1.5 143 16 126 165 8.9 0.2 9 8.5 07/03/2006 21:20:00 2 0.6 3.4 0.7 2.4 0.5 3.4 1.5 2.4 0.5 3.4 1.5 135 24 119 165 9 0.1 9.3 8.5 07/03/2006 21:30:00 1.7 0.5 2.6 0.4 2 0.5 2.6 0.4 2.1 0.5 3 0.7 140 14 138 165 8.9 0.2 9.3 8.5 07/03/2006 21:40:00 2.2 0.5 3.4 0.4 2.4 0.5 3.4 0.7 2.5 0.5 3.8 0.7 141 15 112 165 8.9 0.2 9.3 8.5 07/03/2006 21:50:00 2.5 0.8 4.2 0.7 2.7 0.8 4.2 1.1 2.8 0.7 4.2 1.5 155 12 145 165 9 0 9.3 8.5 07/03/2006 22:00:00 2 0.5 3 0.4 2.3 0.4 3 1.1 2.4 0.4 3.4 1.1 143 10 141 165 9 0 9 8.5 07/03/2006 22:10:00 2.4 0.6 3.8 1.1 2.7 0.6 3.8 1.5 2.8 0.6 4.2 1.9 142 8 156 165 9 0 9 8.8 07/03/2006 22:20:00 3.1 0.3 3.8 2.3 3.3 0.3 4.2 2.3 3.3 0.3 4.2 2.6 137 6 137 165 8.9 0 9 8.8 07/03/2006 22:30:00 2.5 0.7 4.2 0.7 2.8 0.7 4.6 1.1 2.9 0.6 4.6 1.5 147 11 149 165 8.9 0 9 8.8 07/03/2006 22:40:00 2.6 0.5 4.2 1.9 2.8 0.4 4.2 1.9 2.9 0.4 4.2 2.3 145 8 135 165 8.9 0 9.3 8.5 07/03/2006 22:50:00 3.2 0.7 4.6 1.5 3.3 0.7 4.6 1.9 3.4 0.6 4.6 2.3 155 9 153 165 8.9 0 9 8.8 07/03/2006 23:00:00 3.2 0.8 4.9 1.5 3.4 0.8 4.9 1.5 3.4 0.7 4.6 2.3 161 6 167 165 8.9 0 9 8.5 07/03/2006 23:10:00 3.5 0.4 4.6 2.6 3.7 0.4 4.9 2.6 3.9 0.4 5.3 3 156 7 153 165 8.8 0 9.3 8.5 07/03/2006 23:20:00 2.9 0.5 3.8 1.5 3.1 0.4 3.8 1.9 3.3 0.4 4.6 2.3 158 7 153 165 8.8 0 9 8.5 07/03/2006 23:30:00 3.2 0.9 5.3 1.5 3.4 0.8 5.3 1.9 3.6 0.8 5.3 1.9 160 6 150 165 8.9 0 9.3 8.5 07/03/2006 23:40:00 3.6 0.4 4.9 2.6 3.8 0.4 4.9 3 4 0.4 4.9 3 149 8 137 165 8.9 0 9 8.5 07/03/2006 23:50:00 3.5 0.4 4.2 2.6 3.6 0.4 4.6 3 3.8 0.3 4.6 3 146 8 158 165 8.9 0 9 8.5 07/04/2006 00:00:00 3.7 0.5 4.9 2.3 3.8 0.5 5.3 2.6 4 0.5 5.7 3 163 5 160 165 8.9 0 9 8.5 07/04/2006 00:10:00 4.1 0.4 4.9 3 4.2 0.4 4.9 3.4 4.4 0.4 5.3 3.8 159 5 164 165 8.9 0 9 8.5 07/04/2006 00:20:00 3.8 0.6 5.7 2.3 3.8 0.6 5.7 2.6 4 0.6 5.7 3 161 8 160 165 9 0 9.3 8.5 07/04/2006 00:30:00 3.5 0.4 4.9 2.6 3.6 0.4 4.9 3 3.7 0.4 4.9 3 159 6 164 165 9 0 9.6 8.5 07/04/2006 00:40:00 3.6 0.3 4.6 2.6 3.8 0.3 4.6 3 4 0.4 4.9 3.4 157 4 155 165 9 0.1 9.3 8.5 07/04/2006 00:50:00 3.1 0.6 4.2 1.9 3.3 0.6 4.6 1.9 3.5 0.5 4.9 2.3 171 8 168 165 9 0.1 9.3 8.5 07/04/2006 01:00:00 3.2 0.4 4.2 1.9 3.3 0.4 4.2 2.3 3.6 0.4 4.6 2.6 169 9 178 165 9 0.1 9.3 8.5 07/04/2006 01:10:00 3.5 0.3 4.2 2.6 3.6 0.3 4.6 3 3.9 0.4 4.6 3 173 10 187 165 9 0.1 9.3 8.5 07/04/2006 01:20:00 3.6 0.5 4.9 2.6 3.7 0.4 4.9 3 4 0.4 4.9 3 176 9 191 165 9.1 0 9.3 8.8 07/04/2006 01:30:00 3.4 0.3 4.2 2.6 3.5 0.3 4.2 2.6 3.7 0.3 4.6 3 179 6 184 165 9.1 0 9.3 8.8 07/04/2006 01:40:00 4.2 0.4 5.3 3.4 4.2 0.4 5.7 3.4 4.4 0.4 5.7 3.4 172 8 164 165 9.1 0.1 9.6 8.8 07/04/2006 01:50:00 3.8 0.4 4.6 3 3.8 0.3 4.6 3 4.1 0.4 4.9 3 172 5 171 165 9 0.1 9.3 8.5 07/04/2006 02:00:00 3.5 0.4 4.6 2.6 3.6 0.4 4.6 2.6 3.9 0.4 4.6 3 184 6 176 165 9 0.1 9.3 8.5 07/04/2006 02:10:00 3.9 0.5 4.9 2.6 3.9 0.5 4.9 2.6 4.2 0.5 5.3 3 174 9 177 165 9 0.2 9.3 8.5 07/04/2006 02:20:00 4 0.4 4.9 2.6 4 0.4 4.9 2.6 4.3 0.4 5.3 3 179 7 179 165 9 0.1 9.3 8.5 07/04/2006 02:30:00 3.2 0.4 4.2 2.6 3.3 0.4 4.2 2.6 3.6 0.4 4.6 3 174 5 180 165 9 0.2 9.3 8.5 07/04/2006 02:40:00 3.3 0.3 4.2 2.6 3.3 0.3 4.2 2.6 3.7 0.3 4.6 3 175 5 177 165 9 0.2 9.3 8.5 07/04/2006 02:50:00 3.2 0.3 4.2 2.3 3.3 0.3 4.2 2.6 3.6 0.3 4.2 3 178 8 184 165 9 0.2 9.3 8.5 07/04/2006 03:00:00 3.5 0.4 4.6 2.3 3.5 0.4 4.6 2.6 3.8 0.4 4.9 2.6 168 5 180 165 8.9 0.2 9 8.5 07/04/2006 03:10:00 3.2 0.4 4.2 2.3 3.2 0.3 4.2 2.3 3.6 0.3 4.2 3 170 6 166 165 8.9 0.2 9 8.5 07/04/2006 03:20:00 3.8 0.4 4.6 3 3.8 0.3 4.6 3 4.2 0.4 4.9 3.4 167 4 167 165 8.9 0.1 9.3 8.5 07/04/2006 03:30:00 4.3 0.5 5.7 2.6 4.2 0.5 5.3 2.6 4.4 0.4 5.7 3 164 9 158 165 8.9 0.1 9 8.5 07/04/2006 03:40:00 4.2 0.4 4.9 3.4 4.2 0.4 5.3 3 4.5 0.4 5.3 3.4 164 8 169 165 8.9 0 9 8.5 07/04/2006 03:50:00 3.8 0.4 4.9 3 3.9 0.3 4.9 3 4.1 0.4 4.9 3.4 159 5 156 165 8.9 0.1 9 8.5 07/04/2006 04:00:00 3.3 0.5 4.6 1.9 3.2 0.5 4.6 1.9 3.6 0.6 4.6 2.3 163 7 160 165 8.9 0.1 9.3 8.5 07/04/2006 04:10:00 2.7 0.3 3.8 2.3 2.7 0.3 3.4 2.3 3.1 0.3 3.8 2.3 177 6 181 165 9 0.1 9 8.5 07/04/2006 04:20:00 3 0.3 3.8 2.3 3 0.3 3.8 2.3 3.3 0.4 4.2 2.3 174 8 190 165 8.9 0 9 8.5 07/04/2006 04:30:00 2.6 0.3 3.8 1.9 2.8 0.3 3.8 2.3 3.1 0.3 3.8 2.6 166 7 170 165 8.9 0 9 8.5 07/04/2006 04:40:00 2.3 0.4 3 0.7 2.4 0.4 3.4 0.7 2.7 0.4 3.8 1.1 167 8 169 165 8.9 0 9 8.5 07/04/2006 04:50:00 2.2 0.4 3.4 1.1 2.3 0.3 3.4 1.1 2.7 0.3 3.4 1.9 160 7 155 165 8.9 0 9 8.5 07/04/2006 05:00:00 2.6 0.5 3.8 1.5 2.6 0.5 3.8 1.9 2.9 0.4 3.8 2.3 162 10 151 165 9 0 9.3 8.5 07/04/2006 05:10:00 2.5 0.4 3.4 1.9 2.6 0.4 3.4 1.5 2.8 0.3 3.4 1.9 169 6 164 165 9 0.1 9 8.5 07/04/2006 05:20:00 3 0.4 4.2 2.3 3.2 0.3 4.2 2.3 3.4 0.4 4.9 2.6 160 8 164 165 9 0.1 9 8.5 07/04/2006 05:30:00 2.7 0.4 3.8 1.5 2.9 0.3 3.8 1.9 3.2 0.3 4.2 2.6 156 5 160 165 9 0.1 9.3 8.5 07/04/2006 05:40:00 3.5 0.6 4.6 1.5 3.5 0.5 4.6 1.9 3.7 0.5 4.9 2.3 159 9 159 165 9 0.1 9.3 8.5 07/04/2006 05:50:00 3.7 0.4 4.9 2.3 3.8 0.4 4.9 2.3 4 0.4 5.3 2.6 150 8 137 165 9.1 0 9.3 8.8 07/04/2006 06:00:00 4 0.4 4.9 3 4 0.4 4.9 3 4.2 0.3 4.9 3.4 161 7 153 165 9.1 0.1 9.3 8.5 07/04/2006 06:10:00 3.9 0.4 4.9 3 3.9 0.3 4.9 3 4.2 0.4 5.3 3.4 160 4 160 165 9 0.1 9.3 8.5 07/04/2006 06:20:00 4.5 0.5 5.7 3.4 4.5 0.5 5.7 3.4 4.8 0.5 6.1 3.4 157 6 154 165 9.2 0 9.3 8.5 07/04/2006 06:30:00 4.4 0.5 5.7 2.6 4.3 0.5 5.3 2.6 4.5 0.5 5.7 3.4 160 5 158 165 9.4 0.1 9.6 9 07/04/2006 06:40:00 4.3 0.5 5.3 3 4.2 0.5 5.3 3 4.5 0.4 5.3 3.4 158 6 157 165 9.4 0.1 9.6 9 07/04/2006 06:50:00 4.4 0.4 5.3 3.4 4.3 0.4 5.3 3.4 4.6 0.4 5.3 3.8 159 8 152 165 9.4 0 9.6 9 07/04/2006 07:00:00 3.6 0.4 4.9 2.3 3.6 0.4 4.6 2.6 3.9 0.4 5.3 3 160 10 158 165 9.4 0.1 9.6 9 07/04/2006 07:10:00 3.8 0.4 4.6 2.6 3.8 0.3 4.6 2.6 4.1 0.3 4.9 3.4 157 4 154 165 9.4 0.2 9.6 9 07/04/2006 07:20:00 3.8 0.4 4.9 2.6 3.7 0.4 4.9 2.6 4 0.3 4.9 3.4 160 13 162 165 9.4 0.1 9.6 9 07/04/2006 07:30:00 3.4 0.4 4.2 1.9 3.4 0.4 4.6 2.3 3.6 0.5 4.6 1.9 158 8 162 165 9.4 0.1 9.6 9 07/04/2006 07:40:00 3.7 0.3 4.6 2.6 3.6 0.3 4.6 3 4 0.3 4.9 3 161 8 165 165 9.6 0.1 9.8 9.3 07/04/2006 07:50:00 3.7 0.2 4.6 3 3.6 0.2 4.2 3 4 0.3 4.6 3.4 161 12 164 165 9.6 0.1 10.3 9.3 07/04/2006 08:00:00 3.8 0.3 4.6 3 3.7 0.3 4.6 3 4 0.3 4.6 3.4 162 5 161 165 9.6 0.1 9.8 9.3 07/04/2006 08:10:00 3.5 0.3 4.9 3 3.5 0.3 4.9 2.6 3.7 0.4 4.6 2.6 147 11 139 165 9.6 0.1 10.3 9.3 07/04/2006 08:20:00 2.9 0.4 4.2 1.9 2.9 0.4 3.8 1.9 3.2 0.4 4.2 2.3 156 9 156 165 9.6 0.1 9.8 9.3 07/04/2006 08:30:00 3.1 0.3 4.2 2.3 3.1 0.3 4.2 2.3 3.4 0.3 4.2 2.6 160 6 154 165 9.8 0 10.1 9.6 07/04/2006 08:40:00 3.3 0.4 4.2 2.3 3.2 0.4 4.2 2.3 3.5 0.3 4.2 2.6 163 5 165 165 9.9 0 10.3 9.6 07/04/2006 08:50:00 3.1 0.4 4.2 2.3 3.1 0.4 4.2 1.9 3.4 0.4 4.6 2.3 157 9 162 165 10.2 0 10.6 9.8 07/04/2006 09:00:00 2.4 0.5 3.4 1.1 2.4 0.5 3.4 1.1 2.7 0.4 3.8 1.9 154 8 164 165 10.2 0.1 10.6 9.8 07/04/2006 09:10:00 2.6 0.5 3.8 0.7 2.6 0.5 3.8 1.1 2.9 0.4 4.2 1.9 158 7 151 165 10.3 0.2 10.9 9.8 07/04/2006 09:20:00 2.5 0.5 3.8 1.5 2.5 0.5 3.8 1.1 2.8 0.5 4.2 1.9 153 11 145 165 10.7 0.2 11.1 10.3 07/04/2006 09:30:00 3.1 0.4 4.2 1.9 3.1 0.4 4.2 2.3 3.4 0.4 4.6 2.6 151 7 147 165 10.9 0 11.1 10.3 07/04/2006 09:40:00 2.6 0.4 4.2 1.9 2.6 0.4 3.8 1.5 3 0.4 3.8 1.9 148 8 154 165 11.1 0.1 11.4 10.3 07/04/2006 09:50:00 2.5 0.5 3.8 0.7 2.6 0.5 3.8 0.4 3 0.5 4.2 1.9 147 10 144 165 10.9 0 11.1 10.6 07/04/2006 10:00:00 2.9 0.4 4.2 1.5 2.9 0.4 3.8 1.9 3.1 0.4 4.2 2.3 149 11 165 165 11.3 0.1 11.7 10.9 07/04/2006 10:10:00 2.9 0.6 4.2 1.9 2.9 0.5 4.2 1.9 3.3 0.4 4.6 2.3 154 7 153 165 11.2 0 11.4 11.1 07/04/2006 10:20:00 2.9 0.6 4.2 1.5 3 0.5 4.2 1.5 3.3 0.5 4.6 2.3 151 9 139 165 11.3 0 11.7 11.1 07/04/2006 10:30:00 2.9 0.6 4.6 1.5 2.9 0.6 4.6 1.5 3.2 0.5 4.6 1.9 152 10 164 165 11.4 0.1 11.9 11.1 07/04/2006 10:40:00 2.2 0.6 3.8 0.4 2.4 0.5 3.8 0.4 2.7 0.5 3.8 1.5 145 13 151 165 12 0.2 12.5 11.7 07/04/2006 10:50:00 2.4 0.6 3.4 0.4 2.6 0.6 4.2 0.7 2.9 0.5 4.6 1.5 150 15 145 165 12.2 0.2 12.7 11.7 07/04/2006 11:00:00 2.4 0.8 4.2 0.7 2.6 0.7 4.6 1.1 2.8 0.6 4.2 1.5 147 12 150 165 12.1 0.2 12.5 11.7 07/04/2006 11:10:00 1.9 0.7 3.4 0.4 2.2 0.6 3.4 0.7 2.5 0.5 3.8 1.1 138 12 162 165 11.9 0 12.2 11.7 07/04/2006 11:20:00 2.2 0.6 3.4 0.7 2.6 0.5 3.8 1.1 2.7 0.5 3.8 1.1 141 10 143 165 12.2 0 12.5 11.9 07/04/2006 11:30:00 2.4 0.7 3.8 0.4 2.7 0.6 4.2 1.5 2.8 0.5 4.6 1.1 135 16 162 165 12.4 0 12.7 12.2 07/04/2006 11:40:00 2.2 0.6 3.8 0.4 2.6 0.5 3.8 0.7 2.6 0.5 3.8 1.1 141 15 144 165 12.6 0.1 13 11.9 07/04/2006 11:50:00 2.4 0.7 4.6 0.4 2.7 0.6 4.6 0.4 2.7 0.6 4.6 1.1 137 15 151 165 12.5 0 13 12.2 07/04/2006 12:00:00 2.4 0.6 3.8 0.7 2.7 0.6 4.6 1.5 2.9 0.6 4.6 1.5 134 11 142 165 12.3 0.1 12.7 11.9 07/04/2006 12:10:00 2.4 0.5 3.4 1.5 2.6 0.5 3.8 1.5 2.8 0.4 3.8 1.5 140 10 125 165 11.8 0.2 12.5 11.4 07/04/2006 12:20:00 2.6 0.5 4.2 1.5 2.8 0.5 4.2 1.5 3 0.4 3.8 2.3 140 10 121 165 12 0 12.2 11.7 07/04/2006 12:30:00 2.8 0.6 4.6 1.5 3 0.6 4.6 1.5 3.2 0.5 4.6 1.9 143 10 151 165 12.1 0.1 12.5 11.9 07/04/2006 12:40:00 2.9 0.6 4.6 1.1 3.1 0.6 4.6 1.5 3.2 0.6 4.6 1.9 137 13 123 165 12.3 0.1 12.7 11.7 07/04/2006 12:50:00 2.9 0.6 4.6 0.7 3.1 0.6 4.2 1.1 3.3 0.5 4.6 2.3 133 10 154 165 12.9 0.2 13.3 12.5 07/04/2006 13:00:00 3.2 0.7 5.3 1.1 3.4 0.7 5.3 1.5 3.7 0.7 6.1 2.3 135 9 149 165 13 0 13.3 12.7 07/04/2006 13:10:00 3.2 0.6 4.6 1.5 3.4 0.6 4.9 1.5 3.4 0.6 5.3 1.9 140 12 146 165 13.4 0.2 13.8 13 07/04/2006 13:20:00 3 0.7 4.9 1.1 3.2 0.7 4.6 1.1 3.4 0.7 4.9 1.9 134 15 134 165 13.7 0.1 14.1 13 07/04/2006 13:30:00 2.9 0.6 4.2 1.1 3.1 0.6 4.6 1.1 3.3 0.6 4.6 1.9 135 12 148 165 13.4 0 13.8 13 07/04/2006 13:40:00 3.2 0.7 4.6 1.9 3.4 0.6 4.9 1.9 3.5 0.8 4.9 1.5 132 14 139 165 13.6 0 13.8 13.3 07/04/2006 13:50:00 3.9 0.8 6.8 1.9 4 0.8 6.5 2.3 4.1 0.7 6.1 2.3 133 13 145 165 13.8 0 14.1 13.3 07/04/2006 14:00:00 3.5 0.7 5.7 1.5 3.7 0.7 6.1 1.9 3.9 0.7 5.7 1.9 124 15 106 165 13.7 0 14.1 13.3 07/04/2006 14:10:00 3.4 0.6 5.3 1.9 3.6 0.6 5.7 2.3 3.7 0.6 5.3 2.3 127 12 125 165 13.5 0.1 13.8 13 07/04/2006 14:20:00 3.8 0.7 5.7 2.3 4.1 0.7 6.1 2.6 4.1 0.7 6.1 2.3 129 9 124 165 13.9 0.2 14.4 13.5 07/04/2006 14:30:00 4.4 0.6 6.1 3 4.6 0.6 6.1 3 4.7 0.6 6.1 3 127 10 116 165 13.9 0.2 14.6 13.5 07/04/2006 14:40:00 4.1 0.5 5.7 3 4.3 0.5 5.7 3 4.4 0.6 5.7 2.6 128 9 130 165 13.8 0.2 14.4 13.5 07/04/2006 14:50:00 3.7 0.6 5.7 1.9 4 0.6 5.7 2.6 4 0.7 5.7 2.6 126 9 100 165 14.1 0.1 14.4 13.5 07/04/2006 15:00:00 3.1 0.6 4.9 1.5 3.4 0.6 4.9 1.9 3.4 0.5 4.9 2.3 125 7 123 165 14.1 0.1 14.4 13.8 07/04/2006 15:10:00 3.5 0.6 4.9 1.5 3.8 0.5 5.3 1.9 3.8 0.6 5.3 1.9 122 9 107 165 14 0 14.4 13.8 07/04/2006 15:20:00 3.7 0.7 5.3 2.3 3.9 0.7 5.7 2.3 3.9 0.6 5.7 2.3 126 13 127 165 14.1 0 14.4 14.1 07/04/2006 15:30:00 3.8 0.6 5.3 1.9 4 0.6 5.7 2.3 4.1 0.6 5.3 2.3 126 8 134 165 14.4 0.1 14.6 14.1 07/04/2006 15:40:00 3.4 0.7 5.7 1.5 3.6 0.7 6.1 1.9 3.6 0.7 5.7 1.9 128 9 122 165 14.4 0 14.6 14.4 07/04/2006 15:50:00 3.5 0.5 4.9 2.3 3.8 0.5 5.3 2.3 3.9 0.5 5.3 2.6 130 10 163 165 14.2 0.1 14.6 14.1 07/04/2006 16:00:00 3.1 0.5 4.6 2.3 3.4 0.5 4.9 2.3 3.4 0.4 4.9 2.3 124 7 122 165 14.4 0 14.6 14.1 07/04/2006 16:10:00 3.1 0.6 4.9 1.5 3.4 0.6 5.3 2.3 3.3 0.6 5.3 1.9 121 10 118 165 14.4 0 14.9 14.1 07/04/2006 16:20:00 3 0.6 4.9 1.5 3.3 0.6 4.9 1.9 3.3 0.6 5.3 1.9 130 13 112 165 14.5 0.1 14.9 14.4 07/04/2006 16:30:00 3.2 0.6 4.9 1.5 3.5 0.5 4.6 1.9 3.6 0.5 4.9 1.9 125 10 111 165 14.5 0.2 15.2 14.1 07/04/2006 16:40:00 3.2 0.4 4.2 1.9 3.5 0.4 4.9 2.3 3.5 0.5 4.9 2.3 120 9 115 165 14.2 0 14.6 14.1 07/04/2006 16:50:00 2.9 0.5 4.9 1.9 3.2 0.4 4.9 2.3 3.2 0.4 4.2 1.9 118 9 130 165 14.4 0.1 14.9 14.4 07/04/2006 17:00:00 2.7 0.5 4.2 1.5 3.1 0.5 4.6 1.9 3.1 0.5 4.6 1.9 129 11 135 165 14.1 0.2 14.6 13.8 07/04/2006 17:10:00 2.2 0.5 3.4 0.7 2.6 0.4 3.8 1.1 2.6 0.4 3.8 1.9 125 8 127 165 13.8 0 14.1 13.5 07/04/2006 17:20:00 2.5 0.4 3.8 1.5 2.9 0.3 4.2 1.9 2.8 0.4 3.8 1.9 124 7 120 165 13.7 0 13.8 13.5 07/04/2006 17:30:00 2.5 0.4 3.4 1.5 2.9 0.3 3.4 2.3 2.9 0.3 3.8 1.9 119 5 122 165 13.7 0 13.8 13.3 07/04/2006 17:40:00 2.8 0.3 3.8 1.5 3.1 0.3 3.8 1.9 3.1 0.3 3.8 2.3 120 6 118 165 13.5 0 13.5 13 07/04/2006 17:50:00 3.1 0.4 4.2 2.3 3.4 0.3 4.2 2.3 3.4 0.4 4.9 2.3 121 6 150 165 13.4 0 13.5 13.3 07/04/2006 18:00:00 3.3 0.4 4.2 2.3 3.6 0.3 4.6 2.6 3.6 0.3 4.6 2.6 121 4 114 165 13.6 0.1 13.8 13 07/04/2006 18:10:00 3.1 0.3 4.2 2.3 3.4 0.3 4.6 2.6 3.5 0.3 4.6 2.6 120 5 119 165 13.5 0 13.8 13 07/04/2006 18:20:00 3.1 0.3 3.8 2.3 3.4 0.3 4.2 2.6 3.5 0.3 4.6 2.6 118 5 125 165 13.3 0 13.5 13.3 07/04/2006 18:30:00 3 0.3 3.8 2.3 3.2 0.3 4.2 2.3 3.3 0.3 4.2 2.6 118 4 118 165 13.2 0 13.3 12.7 07/04/2006 18:40:00 2.8 0.3 3.4 1.9 3 0.3 3.8 2.3 3.1 0.3 3.8 2.3 120 7 116 165 13.1 0 13.3 13 07/04/2006 18:50:00 2.9 0.3 3.8 2.3 3.1 0.3 3.8 2.3 3.2 0.3 4.2 2.6 118 5 106 165 13.2 0 13.3 13 07/04/2006 19:00:00 3.2 0.3 4.2 2.3 3.4 0.3 4.2 2.6 3.5 0.3 4.2 2.6 120 5 115 165 13.2 0 13.3 13 07/04/2006 19:10:00 3.4 0.4 4.2 1.9 3.6 0.4 4.6 1.9 3.6 0.4 4.9 2.6 124 7 118 165 13 0 13.3 13 07/04/2006 19:20:00 3.4 0.3 4.2 2.6 3.5 0.3 4.2 2.6 3.5 0.3 4.2 2.6 121 5 123 165 12.9 0 13.5 12.7 07/04/2006 19:30:00 3.2 0.3 4.2 2.3 3.4 0.3 4.6 2.6 3.4 0.3 4.6 2.3 119 5 116 165 12.8 0 13 12.7 07/04/2006 19:40:00 3.1 0.4 3.8 2.3 3.3 0.4 4.2 2.3 3.4 0.3 4.2 2.6 128 5 128 165 12.7 0 13 12.5 07/04/2006 19:50:00 2.7 0.3 3.4 1.9 2.9 0.3 3.4 2.3 3.1 0.3 3.8 2.3 121 5 130 165 12.6 0 12.7 12.5 07/04/2006 20:00:00 2.6 0.4 3.4 1.9 2.8 0.3 3.8 2.3 2.9 0.3 3.8 2.3 122 7 130 165 12.4 0 12.7 12.2 07/04/2006 20:10:00 2.7 0.2 3.4 2.3 2.9 0.2 3.4 2.3 3 0.3 3.4 2.3 123 4 126 165 12.3 0.1 12.7 11.9 07/04/2006 20:20:00 2.9 0.3 3.4 2.3 3 0.3 3.8 2.3 3.1 0.2 3.8 2.3 123 7 121 165 12.1 0 12.5 11.7 07/04/2006 20:30:00 2.7 0.4 3.4 1.5 2.9 0.3 3.8 2.3 3 0.3 3.8 2.3 123 6 128 165 12.1 0 12.7 11.7 07/04/2006 20:40:00 2.5 0.3 3.4 1.5 2.8 0.3 3.8 2.3 2.8 0.3 3.8 1.9 119 4 114 165 11.9 0 12.2 11.4 07/04/2006 20:50:00 2 0.4 3 1.1 2.3 0.4 3 1.5 2.4 0.3 3 1.5 122 5 128 165 11.8 0.1 11.9 11.4 07/04/2006 21:00:00 1.9 0.4 2.6 0.7 2.3 0.4 3 1.5 2.5 0.3 3 1.5 113 5 117 165 11.7 0 11.9 11.4 07/04/2006 21:10:00 2.4 0.3 3 1.5 2.7 0.3 3.4 1.9 2.6 0.3 3.4 1.5 114 5 108 165 11.7 0 11.9 11.7 07/04/2006 21:20:00 2.3 0.3 3 1.5 2.6 0.3 3.4 1.9 2.6 0.3 3 1.9 116 4 111 165 11.5 0 11.7 11.4 07/04/2006 21:30:00 2.6 0.5 3.8 1.5 2.9 0.4 4.2 1.9 2.9 0.4 3.8 1.9 119 3 115 165 11.4 0 11.7 11.4 07/04/2006 21:40:00 2.7 0.4 3.8 1.5 2.9 0.4 3.8 1.9 2.9 0.3 3.8 2.3 121 6 128 165 11.3 0 11.7 11.4 07/04/2006 21:50:00 2.3 0.4 3 1.5 2.6 0.3 3.4 1.9 2.6 0.4 3.4 1.5 119 7 111 165 11.3 0 11.7 11.1 07/04/2006 22:00:00 2.7 0.4 3.8 1.5 3.1 0.4 3.8 1.9 3 0.4 3.8 1.9 119 6 126 165 11.3 0 11.4 11.1 07/04/2006 22:10:00 2.6 0.4 3.8 1.5 2.9 0.4 3.8 1.9 2.9 0.4 3.8 2.3 117 6 121 165 11.3 0 11.7 11.1 07/04/2006 22:20:00 3.1 0.5 4.6 1.9 3.4 0.5 4.6 2.3 3.2 0.4 4.2 2.3 120 9 121 165 11.2 0 11.4 11.1 07/04/2006 22:30:00 3.2 0.4 4.2 2.3 3.4 0.4 4.2 2.6 3.3 0.4 4.6 2.3 124 7 135 165 11.1 0 11.4 10.9 07/04/2006 22:40:00 2.9 0.5 4.2 1.5 3.1 0.5 4.2 1.9 3 0.4 4.2 1.9 122 9 136 165 11.1 0 11.4 10.9 07/04/2006 22:50:00 2.9 0.6 4.2 1.5 3.1 0.6 4.2 1.9 3 0.6 4.6 1.5 125 9 132 165 11.1 0 11.4 10.9 07/04/2006 23:00:00 3 0.5 4.2 1.9 3.2 0.4 4.2 1.9 3.1 0.5 4.2 1.9 126 9 125 165 11.1 0 11.4 10.9 07/04/2006 23:10:00 2.4 0.4 3 1.5 2.7 0.3 3.4 1.9 2.7 0.3 3.4 1.9 129 6 128 165 11.1 0 11.4 10.9 07/04/2006 23:20:00 1.7 0.4 2.6 0.4 2.2 0.3 3 1.1 2.2 0.3 3 1.5 118 8 128 165 11.2 0.1 11.4 10.9 07/04/2006 23:30:00 1.1 0.4 1.9 0.4 1.7 0.4 2.6 1.1 1.9 0.3 2.6 1.1 117 5 115 165 11.2 0 11.4 10.9 07/04/2006 23:40:00 1 0.4 1.9 0.4 1.6 0.3 2.3 0.7 1.7 0.3 2.6 0.7 114 6 112 165 11.1 0 11.4 10.9 07/04/2006 23:50:00 1.3 0.2 1.9 0.7 1.9 0.2 2.3 1.5 2 0.2 2.6 1.5 108 3 105 165 11.1 0.1 11.4 10.9 07/05/2006 00:00:00 1.9 0.3 2.6 1.1 2.2 0.3 2.6 1.5 2.4 0.3 3 1.9 107 5 105 165 11.1 0.1 11.4 10.9 07/05/2006 00:10:00 1.9 0.6 3.4 0.7 2.2 0.5 3.8 1.5 2.4 0.5 3.4 1.5 102 5 106 165 11.1 0.1 11.4 10.9 07/05/2006 00:20:00 1.6 0.4 2.6 0.4 2.1 0.4 3 1.1 2.3 0.3 3 1.5 96 5 84 165 11.1 0.1 11.4 10.9 07/05/2006 00:30:00 0.9 0.6 2.3 0.4 1.4 0.7 3 0.4 1.6 0.8 3 0.4 84 6 91 165 11.1 0.2 11.4 10.9 07/05/2006 00:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 78 0 165 165 11.3 0.1 11.4 10.9 07/05/2006 00:50:00 0.4 0 0.4 0.4 0.4 0.1 0.7 0.4 0.6 0.3 1.1 0.4 58 30 165 165 11.3 0.1 11.4 10.9 07/05/2006 01:00:00 0.4 0 0.4 0.4 0.4 0 0.7 0.4 0.6 0.3 1.5 0.4 14 0 165 165 11.2 0.1 11.4 10.9 07/05/2006 01:10:00 1.1 0.3 1.5 0.4 0.6 0.2 1.1 0.4 1.6 0.3 2.3 1.1 3 3 2 165 11 0.2 11.4 10.9 07/05/2006 01:20:00 1.3 0.3 1.9 0.7 1 0.2 1.5 0.4 1.9 0.2 2.3 1.5 0 1 360 165 10.9 0.1 11.1 10.6 07/05/2006 01:30:00 0.4 0.1 1.1 0.4 0.5 0.2 1.5 0.4 0.8 0.4 1.9 0.4 4 0 4 165 10.9 0 11.1 10.6 07/05/2006 01:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0.2 1.1 0.4 44 29 165 165 11 0 11.1 10.6 07/05/2006 01:50:00 0.4 0.2 1.1 0.4 0.6 0.4 1.9 0.4 0.6 0.4 1.9 0.4 82 6 84 165 11 0 11.1 10.3 07/05/2006 02:00:00 0.4 0.1 0.7 0.4 0.4 0.1 1.1 0.4 0.6 0.4 1.5 0.4 84 0 84 165 11 0.2 11.4 10.6 07/05/2006 02:10:00 0.5 0.3 1.1 0.4 0.6 0.4 1.5 0.4 0.7 0.4 1.5 0.4 93 6 95 165 11 0.1 11.4 10.3 07/05/2006 02:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 97 0 165 165 10.9 0.1 11.4 10.3 07/05/2006 02:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 97 0 165 165 10.9 0.2 11.1 10.3 07/05/2006 02:40:00 0.5 0.3 1.5 0.4 0.5 0.3 1.5 0.4 0.6 0.3 1.1 0.4 53 13 63 165 10.7 0.3 11.1 10.3 07/05/2006 02:50:00 0.5 0.2 1.1 0.4 0.5 0.3 1.1 0.4 0.8 0.3 1.5 0.4 63 0 63 165 10.7 0.2 11.1 10.3 07/05/2006 03:00:00 0.5 0.2 1.1 0.4 0.5 0.3 1.5 0.4 0.8 0.5 1.5 0.4 28 29 3 165 10.7 0.3 11.1 10.3 07/05/2006 03:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.8 0.3 1.1 0.4 2 0 165 165 10.7 0.2 10.9 10.3 07/05/2006 03:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 2 0 165 165 10.7 0.2 11.1 10.3 07/05/2006 03:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 2 0 165 165 10.9 0.1 11.1 10.3 07/05/2006 03:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.5 0.2 1.1 0.4 2 0 165 165 10.9 0 11.1 10.3 07/05/2006 03:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.8 0.2 1.1 0.4 3 0 165 165 10.9 0.1 11.4 10.6 07/05/2006 04:00:00 0.8 0.2 1.1 0.4 0.8 0.4 1.5 0.4 1.2 0.2 1.5 0.7 354 5 3 165 10.9 0.1 11.1 10.3 07/05/2006 04:10:00 0.4 0.2 1.1 0.4 0.5 0.2 1.1 0.4 0.9 0.3 1.5 0.4 5 0 5 165 10.8 0.1 11.1 10.3 07/05/2006 04:20:00 0.5 0.2 1.1 0.4 0.4 0.1 1.1 0.4 0.9 0.5 1.9 0.4 5 0 5 165 10.9 0 11.1 10.6 07/05/2006 04:30:00 1.4 0.3 1.9 0.7 1.3 0.4 1.9 0.4 1.9 0.3 2.3 1.1 16 5 16 165 10.8 0 11.1 10.3 07/05/2006 04:40:00 1.6 0.2 1.9 1.1 1.7 0.2 2.3 1.1 2 0.2 2.6 1.5 22 2 21 165 10.7 0 10.9 10.3 07/05/2006 04:50:00 1.9 0.2 2.3 1.1 2 0.3 2.6 1.1 2.1 0.2 2.6 1.1 33 5 27 165 10.7 0.1 10.9 10.3 07/05/2006 05:00:00 1.6 0.3 2.3 0.7 1.7 0.4 2.3 0.7 1.8 0.4 2.6 1.1 45 6 36 165 10.7 0 10.9 10.9 07/05/2006 05:10:00 1 0.3 1.9 0.4 1 0.4 1.9 0.4 1.3 0.3 2.3 0.7 47 7 46 165 10.7 0 10.9 10.6 07/05/2006 05:20:00 1.5 0.5 2.3 0.4 1.6 0.4 2.3 0.4 2 0.4 2.6 1.1 26 9 29 165 10.8 0 10.9 10.6 07/05/2006 05:30:00 1.9 0.3 2.6 1.1 1.8 0.5 2.6 0.4 2.2 0.3 3 1.1 19 8 26 165 10.8 0 11.1 10.9 07/05/2006 05:40:00 1.1 0.5 2.3 0.4 1 0.6 2.3 0.4 1.3 0.5 2.6 0.4 32 12 37 165 10.8 0 11.4 10.9 07/05/2006 05:50:00 1.3 0.3 2.3 0.4 1 0.4 1.9 0.4 1.6 0.3 2.6 0.7 15 5 13 165 10.9 0 11.1 10.6 07/05/2006 06:00:00 0.8 0.5 1.9 0.4 0.8 0.5 1.9 0.4 1 0.6 2.6 0.4 22 5 32 165 11 0 11.4 10.6 07/05/2006 06:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 20 0 165 165 11.2 0 11.4 10.9 07/05/2006 06:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 21 4 165 165 11.2 0 11.4 10.9 07/05/2006 06:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 105 0 165 165 11.1 0 11.4 10.6 07/05/2006 06:40:00 0.4 0 0.7 0.4 0.4 0 0.7 0.4 0.4 0.1 0.7 0.4 349 47 330 165 11.2 0.1 11.7 10.9 07/05/2006 06:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 330 0 165 165 11.3 0.1 11.7 10.9 07/05/2006 07:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 330 0 165 165 11.3 0.1 11.7 10.9 07/05/2006 07:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 330 3 165 165 11.7 0.1 11.9 11.4 07/05/2006 07:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 61 3 165 165 11.4 0.2 11.7 11.1 07/05/2006 07:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0.1 1.1 0.4 94 21 165 165 11.3 0 11.7 11.1 07/05/2006 07:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0.1 0.7 0.4 5 18 165 165 11.7 0.1 12.2 11.4 07/05/2006 07:50:00 0.6 0.3 1.5 0.4 0.4 0.2 1.1 0.4 0.9 0.3 1.5 0.4 12 7 29 165 12 0 12.2 11.7 07/05/2006 08:00:00 0.6 0.3 1.5 0.4 0.4 0.2 1.5 0.4 0.9 0.4 1.9 0.4 3 5 10 165 12.2 0 12.5 11.9 07/05/2006 08:10:00 0.9 0.5 2.3 0.4 0.6 0.4 1.9 0.4 1.2 0.5 3 0.4 4 10 7 165 12.3 0.2 12.5 11.9 07/05/2006 08:20:00 1.3 0.4 2.3 0.4 1 0.5 2.3 0.4 1.7 0.3 2.6 0.7 12 8 1 165 12.1 0.1 12.5 11.7 07/05/2006 08:30:00 0.9 0.3 1.9 0.4 0.7 0.4 1.9 0.4 1.5 0.3 2.3 0.4 0 13 23 165 12 0 12.2 11.7 07/05/2006 08:40:00 0.7 0.4 1.9 0.4 0.7 0.4 1.9 0.4 1.1 0.6 2.3 0.4 342 7 345 165 12.3 0.2 12.5 11.7 07/05/2006 08:50:00 0.4 0.1 1.1 0.4 0.4 0 0.7 0.4 0.5 0.3 1.5 0.4 5 5 2 165 12.5 0 12.7 11.9 07/05/2006 09:00:00 0.5 0.2 1.5 0.4 0.4 0.2 1.5 0.4 0.4 0.2 1.5 0.4 8 15 10 165 12.4 0.1 12.7 11.9 07/05/2006 09:10:00 0.8 0.4 2.3 0.4 0.6 0.4 1.9 0.4 1 0.5 2.3 0.4 6 21 34 165 12.3 0.1 12.5 11.9 07/05/2006 09:20:00 0.5 0.2 1.5 0.4 0.4 0.2 1.5 0.4 0.9 0.5 1.9 0.4 24 11 38 165 12.3 0 12.7 11.9 07/05/2006 09:30:00 0.4 0 0.7 0.4 0.4 0 0.7 0.4 0.5 0.2 1.5 0.4 39 20 25 165 12.5 0.1 12.7 12.2 07/05/2006 09:40:00 0.4 0 0.7 0.4 0.4 0 0.4 0.4 0.4 0.1 1.1 0.4 132 41 326 165 12.9 0.1 13 12.5 07/05/2006 09:50:00 0.4 0.2 1.9 0.4 0.4 0.1 1.5 0.4 0.5 0.3 1.9 0.4 355 43 356 165 12.7 0 12.7 12.2 07/05/2006 10:00:00 0.5 0.2 1.5 0.4 0.4 0.2 1.1 0.4 0.7 0.4 1.9 0.4 99 23 142 165 12.4 0.2 12.7 11.7 07/05/2006 10:10:00 0.4 0.2 1.1 0.4 0.4 0.1 1.1 0.4 0.5 0.3 1.5 0.4 86 22 107 165 12.1 0 12.5 11.9 07/05/2006 10:20:00 0.6 0.4 1.9 0.4 0.6 0.4 1.9 0.4 0.7 0.4 1.5 0.4 53 53 358 165 12.4 0.2 12.7 11.7 07/05/2006 10:30:00 0.4 0.1 1.1 0.4 0.4 0.1 1.1 0.4 0.6 0.3 1.5 0.4 107 3 106 165 11.9 0 12.5 11.4 07/05/2006 10:40:00 0.6 0.4 1.9 0.4 0.6 0.4 1.9 0.4 1.2 0.4 1.9 0.4 129 13 135 165 12 0 12.2 11.9 07/05/2006 10:50:00 0.5 0.3 1.5 0.4 0.6 0.4 1.9 0.4 1 0.5 2.3 0.4 109 10 132 165 11.9 0 12.2 11.9 07/05/2006 11:00:00 0.4 0.1 1.1 0.4 0.4 0.1 1.1 0.4 0.4 0.3 1.9 0.4 92 3 105 165 12.1 0 12.5 11.7 07/05/2006 11:10:00 0.4 0.1 1.1 0.4 0.4 0.2 1.5 0.4 0.6 0.3 1.5 0.4 108 10 119 165 12.1 0.2 12.5 11.4 07/05/2006 11:20:00 0.6 0.5 2.3 0.4 0.6 0.5 2.3 0.4 0.6 0.5 2.3 0.4 40 58 10 165 12.7 0.3 13.3 11.9 07/05/2006 11:30:00 0.4 0.2 1.9 0.4 0.5 0.3 2.3 0.4 0.5 0.3 1.9 0.4 54 49 339 165 13.1 0.1 13.5 12.7 07/05/2006 11:40:00 0.6 0.3 1.5 0.4 0.6 0.3 1.9 0.4 0.6 0.3 1.5 0.4 46 51 95 165 13 0.1 13.5 12.5 07/05/2006 11:50:00 0.8 0.4 2.3 0.4 0.8 0.5 2.3 0.4 0.9 0.5 2.3 0.4 16 17 31 165 13.5 0.1 13.8 13 07/05/2006 12:00:00 0.7 0.4 1.9 0.4 0.8 0.5 2.3 0.4 0.8 0.5 2.6 0.4 29 24 11 165 13.9 0 14.4 13.5 07/05/2006 12:10:00 0.8 0.6 2.6 0.4 0.9 0.6 2.6 0.4 1 0.6 2.6 0.4 14 14 5 165 13.7 0 13.8 13.5 07/05/2006 12:20:00 0.5 0.4 2.3 0.4 0.6 0.5 2.3 0.4 0.7 0.5 3.4 0.4 72 41 65 165 13.6 0 13.8 13.3 07/05/2006 12:30:00 0.4 0.1 1.1 0.4 0.4 0.2 1.5 0.4 0.4 0.1 1.1 0.4 75 33 58 165 13.1 0 13.5 13 07/05/2006 12:40:00 0.4 0.1 1.1 0.4 0.4 0.2 1.5 0.4 0.4 0.1 1.1 0.4 71 32 81 165 13.3 0 13.3 13 07/05/2006 12:50:00 0.6 0.4 2.3 0.4 0.6 0.5 2.3 0.4 0.5 0.3 1.5 0.4 114 94 329 165 13.6 0 13.8 13.3 07/05/2006 13:00:00 0.7 0.5 2.3 0.4 0.6 0.4 1.9 0.4 0.5 0.3 1.9 0.4 19 69 359 165 13.9 0.1 14.1 13.5 07/05/2006 13:10:00 1 0.7 2.6 0.4 0.9 0.6 2.6 0.4 0.9 0.6 2.6 0.4 61 61 21 165 13.9 0 14.1 13.3 07/05/2006 13:20:00 0.6 0.4 1.9 0.4 0.6 0.4 1.9 0.4 0.6 0.4 1.9 0.4 58 56 115 165 13.6 0.1 13.8 13 07/05/2006 13:30:00 0.6 0.4 1.9 0.4 0.7 0.4 1.9 0.4 0.6 0.3 1.5 0.4 98 10 108 165 13.5 0 13.5 13.3 07/05/2006 13:40:00 0.5 0.3 1.5 0.4 0.6 0.4 1.5 0.4 0.5 0.3 1.5 0.4 97 11 100 165 13.4 0 13.5 13 07/05/2006 13:50:00 0.4 0.2 1.1 0.4 0.5 0.3 1.5 0.4 0.4 0.2 1.1 0.4 109 19 119 165 13.3 0 13.5 13 07/05/2006 14:00:00 0.5 0.3 1.9 0.4 0.6 0.4 1.9 0.4 0.7 0.4 1.9 0.4 117 21 129 165 13.1 0 13.3 12.5 07/05/2006 14:10:00 0.6 0.5 2.6 0.4 0.6 0.5 2.6 0.4 0.5 0.4 1.9 0.4 60 41 26 165 13.8 0.2 14.1 13.3 07/05/2006 14:20:00 1 0.7 2.6 0.4 1.1 0.7 2.6 0.4 0.9 0.6 2.3 0.4 72 61 18 165 13.9 0.1 14.1 13.3 07/05/2006 14:30:00 0.4 0 0.7 0.4 0.4 0.1 1.1 0.4 0.5 0.3 1.9 0.4 126 5 131 165 13.7 0.2 14.1 13.3 07/05/2006 14:40:00 0.4 0 0.7 0.4 0.4 0.1 1.1 0.4 0.4 0.1 1.5 0.4 173 69 150 165 13.4 0 13.5 13.3 07/05/2006 14:50:00 0.7 0.5 2.3 0.4 0.7 0.5 2.3 0.4 0.4 0.2 1.5 0.4 18 72 22 165 13.3 0 13.5 13 07/05/2006 15:00:00 1.6 0.9 3 0.4 1.3 0.8 2.6 0.4 1 0.7 2.6 0.4 5 30 32 165 13.5 0 13.8 13.3 07/05/2006 15:10:00 2.2 0.4 3 1.1 1.9 0.5 3 0.7 1.9 0.5 3 0.4 10 12 7 165 14.1 0.3 14.6 13.8 07/05/2006 15:20:00 1.9 0.5 3 0.7 1.6 0.5 2.6 0.4 1.7 0.6 3 0.4 17 15 3 165 14.6 0 14.9 14.4 07/05/2006 15:30:00 1.8 0.6 3.8 0.4 1.6 0.7 3.4 0.4 1.7 0.7 3.4 0.4 24 20 34 165 14.3 0.1 14.6 14.1 07/05/2006 15:40:00 1.9 0.6 3.4 0.4 1.9 0.6 3.4 0.4 1.8 0.6 3 0.4 39 22 46 165 13.9 0 14.4 13.5 07/05/2006 15:50:00 2.2 0.4 3.4 1.1 2.4 0.4 3.4 1.1 2.4 0.4 3.4 1.1 29 15 35 165 13.7 0 14.1 13.5 07/05/2006 16:00:00 1.7 0.4 2.6 0.7 2 0.5 3 0.4 1.9 0.5 3 0.4 39 10 44 165 13.5 0 13.8 13.3 07/05/2006 16:10:00 1.4 0.4 2.3 0.4 1.5 0.5 2.6 0.4 1.6 0.5 2.6 0.4 40 13 41 165 13.3 0 13.5 13 07/05/2006 16:20:00 0.8 0.5 2.3 0.4 0.7 0.4 1.5 0.4 0.8 0.5 2.3 0.4 61 53 354 165 13.5 0 13.5 13.3 07/05/2006 16:30:00 1.1 0.6 3 0.4 1.1 0.6 3 0.4 1.1 0.5 3.8 0.4 47 30 50 165 13.5 0 14.1 13.3 07/05/2006 16:40:00 0.4 0.2 1.9 0.4 0.4 0.2 1.9 0.4 0.4 0.1 1.1 0.4 91 53 66 165 13.5 0 13.8 13.3 07/05/2006 16:50:00 1.2 0.5 2.3 0.4 0.8 0.4 2.6 0.4 1.1 0.6 2.6 0.4 6 27 22 165 13.4 0 13.5 13 07/05/2006 17:00:00 1.7 0.4 2.6 0.4 1.3 0.5 2.3 0.4 1.9 0.4 2.6 0.4 7 9 356 165 13.3 0.1 13.5 12.7 07/05/2006 17:10:00 1.3 0.3 2.6 0.4 1.1 0.5 2.6 0.4 1.5 0.4 2.6 0.4 11 8 10 165 13.5 0.1 13.5 13 07/05/2006 17:20:00 1 0.4 1.9 0.4 0.8 0.4 1.9 0.4 1.2 0.4 1.9 0.4 19 12 32 165 13.2 0.1 13.5 12.7 07/05/2006 17:30:00 0.7 0.5 2.3 0.4 0.6 0.4 2.3 0.4 0.8 0.5 2.6 0.4 12 22 2 165 13.3 0.2 13.5 12.7 07/05/2006 17:40:00 0.4 0.1 0.7 0.4 0.4 0.1 1.1 0.4 0.4 0.2 1.9 0.4 22 27 45 165 13.7 0 13.8 13.3 07/05/2006 17:50:00 0.4 0.1 1.1 0.4 0.4 0 0.7 0.4 0.4 0.1 1.1 0.4 327 14 323 165 13.8 0 14.1 13.3 07/05/2006 18:00:00 0.4 0.1 1.1 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 332 17 337 165 13.9 0 14.1 13.5 07/05/2006 18:10:00 0.5 0.3 1.5 0.4 0.4 0.1 1.5 0.4 0.5 0.3 1.5 0.4 356 13 352 165 13.5 0 13.8 13 07/05/2006 18:20:00 0.6 0.4 1.5 0.4 0.5 0.3 1.9 0.4 0.5 0.3 1.5 0.4 8 6 1 165 13.3 0 13.5 12.7 07/05/2006 18:30:00 1.1 0.3 1.9 0.4 0.9 0.5 2.3 0.4 1.4 0.3 2.3 0.7 15 10 9 165 13.1 0.1 13.3 12.5 07/05/2006 18:40:00 1.3 0.3 2.3 0.4 1.3 0.4 2.3 0.4 1.6 0.3 2.3 0.7 35 11 24 165 13 0.1 13.3 12.5 07/05/2006 18:50:00 1.1 0.3 1.9 0.4 1.1 0.3 1.9 0.4 1.4 0.3 2.3 0.7 35 3 34 165 12.9 0 13 12.2 07/05/2006 19:00:00 0.7 0.4 1.5 0.4 0.7 0.4 1.9 0.4 1.2 0.4 1.9 0.4 46 11 34 165 12.7 0 13 12.5 07/05/2006 19:10:00 0.9 0.4 2.3 0.4 1 0.5 2.3 0.4 1.2 0.4 1.9 0.4 35 12 52 165 12.6 0 12.7 12.5 07/05/2006 19:20:00 1.1 0.4 2.3 0.4 1.3 0.5 2.6 0.4 1.4 0.4 2.3 0.4 53 9 49 165 12.5 0 12.7 12.5 07/05/2006 19:30:00 0.8 0.4 1.9 0.4 0.9 0.4 2.3 0.4 1.2 0.4 2.3 0.4 39 7 32 165 12.5 0 12.7 12.5 07/05/2006 19:40:00 0.7 0.4 1.9 0.4 0.7 0.5 2.3 0.4 0.6 0.4 1.9 0.4 48 15 59 165 12.5 0 12.7 12.5 07/05/2006 19:50:00 0.6 0.4 1.5 0.4 0.5 0.3 1.5 0.4 0.7 0.5 2.3 0.4 48 8 36 165 12.4 0 12.7 12.5 07/05/2006 20:00:00 0.4 0.2 1.5 0.4 0.4 0.2 1.1 0.4 0.5 0.4 1.5 0.4 45 0 44 165 12.3 0 12.5 12.2 07/05/2006 20:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 40 3 165 165 12.3 0 12.5 12.2 07/05/2006 20:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 38 0 165 165 12.3 0 12.5 12.2 07/05/2006 20:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0.1 0.7 0.4 83 12 165 165 12.1 0 12.5 11.9 07/05/2006 20:40:00 0.4 0.2 1.5 0.4 0.4 0.2 1.5 0.4 0.5 0.2 1.1 0.4 97 12 110 165 12.1 0 12.5 11.9 07/05/2006 20:50:00 0.4 0.1 0.7 0.4 0.4 0 0.7 0.4 0.4 0 0.7 0.4 105 1 105 165 11.9 0 12.2 11.9 07/05/2006 21:00:00 0.4 0 0.7 0.4 0.4 0 0.4 0.4 0.4 0.2 1.1 0.4 25 38 3 165 12 0 12.2 11.9 07/05/2006 21:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0 10 165 165 11.9 0.1 12.2 11.4 07/05/2006 21:20:00 0.5 0.2 1.1 0.4 0.4 0.2 1.1 0.4 0.5 0.3 1.1 0.4 278 27 253 165 11.9 0.1 12.2 11.4 07/05/2006 21:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0.1 0.7 0.4 253 0 165 165 12 0 12.2 11.4 07/05/2006 21:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 253 0 165 165 12.1 0 12.2 11.4 07/05/2006 21:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 253 0 165 165 12.1 0 12.5 11.7 07/05/2006 22:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 237 19 165 165 12.1 0 12.2 11.7 07/05/2006 22:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 175 8 165 165 12 0 12.2 11.4 07/05/2006 22:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 166 0 165 165 11.9 0 12.2 11.7 07/05/2006 22:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0.2 1.1 0.4 166 0 165 165 11.9 0 11.9 11.7 07/05/2006 22:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 166 0 165 165 11.8 0 11.9 11.7 07/05/2006 22:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 166 0 165 165 11.9 0 11.9 11.7 07/05/2006 23:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 166 0 165 165 11.9 0 12.2 11.7 07/05/2006 23:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 166 0 165 165 12 0 12.2 11.7 07/05/2006 23:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 166 0 165 165 12.1 0 12.2 11.7 07/05/2006 23:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 166 0 165 165 12.1 0 12.2 11.9 07/05/2006 23:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0.2 1.1 0.4 166 0 165 165 12.1 0 12.2 11.9 07/05/2006 23:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.6 0.3 1.1 0.4 166 0 165 165 12.1 0 12.2 11.9 07/06/2006 00:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 166 0 165 165 12.1 0 12.2 11.9 07/06/2006 00:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 166 0 165 165 12.1 0 12.5 11.9 07/06/2006 00:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 166 0 165 165 12.2 0 12.5 11.9 07/06/2006 00:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 166 0 165 165 12.1 0 12.2 11.9 07/06/2006 00:40:00 0.5 0.3 1.5 0.4 0.4 0 0.4 0.4 0.6 0.3 1.5 0.4 166 0 166 165 12.1 0 12.5 11.9 07/06/2006 00:50:00 0.4 0 0.7 0.4 0.4 0 0.4 0.4 0.4 0.1 0.7 0.4 166 0 166 165 12.2 0 12.5 11.9 07/06/2006 01:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 166 0 165 165 12.2 0 12.5 11.9 07/06/2006 01:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 166 0 165 165 12.2 0 12.5 11.9 07/06/2006 01:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 166 0 165 165 12.2 0 12.5 11.9 07/06/2006 01:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 166 0 165 165 12.1 0 12.5 11.7 07/06/2006 01:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 166 0 165 165 12.1 0 12.2 11.7 07/06/2006 01:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 166 0 165 165 11.9 0.1 12.2 11.7 07/06/2006 02:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 166 0 165 165 11.8 0.1 11.9 11.7 07/06/2006 02:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 166 0 165 165 11.8 0.1 11.9 11.4 07/06/2006 02:20:00 0.4 0 0.4 0.4 0.4 0 0.7 0.4 0.4 0 0.4 0.4 166 0 165 165 11.8 0.1 11.9 11.4 07/06/2006 02:30:00 0.4 0 0.4 0.4 0.4 0.1 0.7 0.4 0.4 0.2 1.1 0.4 147 2 165 165 11.7 0.1 11.9 11.4 07/06/2006 02:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 147 0 165 165 11.7 0.2 12.2 11.4 07/06/2006 02:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 147 0 165 165 11.6 0.1 11.9 11.4 07/06/2006 03:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 192 30 165 165 11.6 0.1 11.7 11.1 07/06/2006 03:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 213 0 165 165 11.6 0.1 11.9 11.1 07/06/2006 03:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 213 0 165 165 11.6 0.1 11.9 11.1 07/06/2006 03:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 213 0 165 165 11.7 0.1 11.9 11.1 07/06/2006 03:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 213 0 165 165 11.7 0.2 11.9 11.4 07/06/2006 03:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 213 0 165 165 11.7 0.1 11.9 11.4 07/06/2006 04:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 213 0 165 165 11.7 0 11.9 11.1 07/06/2006 04:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 213 0 165 165 11.7 0 11.9 11.4 07/06/2006 04:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 213 0 165 165 11.7 0.1 11.9 11.4 07/06/2006 04:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 213 0 165 165 11.7 0.1 11.9 11.4 07/06/2006 04:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 213 0 165 165 11.7 0.1 11.9 11.1 07/06/2006 04:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 213 0 165 165 11.7 0.1 11.9 11.4 07/06/2006 05:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0.1 0.7 0.4 203 19 165 165 11.7 0.1 11.9 11.1 07/06/2006 05:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.9 0.2 1.5 0.4 159 8 165 165 11.5 0.1 11.9 11.1 07/06/2006 05:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.9 0.2 1.5 0.4 143 1 165 165 11.5 0.1 11.7 11.1 07/06/2006 05:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0.1 0.7 0.4 143 0 165 165 11.6 0.1 11.9 11.1 07/06/2006 05:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 143 0 165 165 11.7 0.1 11.9 11.1 07/06/2006 05:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 143 0 165 165 11.7 0.1 11.9 11.1 07/06/2006 06:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 143 0 165 165 11.7 0.1 11.9 11.4 07/06/2006 06:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 143 0 165 165 11.7 0.1 11.9 11.4 07/06/2006 06:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 143 0 165 165 11.6 0.2 11.9 11.4 07/06/2006 06:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 143 0 165 165 11.6 0.2 11.9 11.4 07/06/2006 06:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 143 0 165 165 11.7 0.1 11.9 11.4 07/06/2006 06:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 143 0 165 165 11.7 0.2 11.9 11.1 07/06/2006 07:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 143 0 165 165 11.8 0.1 11.9 11.4 07/06/2006 07:10:00 0.4 0 0.7 0.4 0.4 0 0.4 0.4 0.4 0 0.7 0.4 171 36 227 165 11.9 0 12.2 11.7 07/06/2006 07:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 222 0 165 165 12 0 12.2 11.7 07/06/2006 07:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 204 22 165 165 11.9 0.1 12.2 11.7 07/06/2006 07:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.7 0.4 171 0 165 165 11.8 0.1 11.9 11.4 07/06/2006 07:50:00 0.4 0.1 1.1 0.4 0.4 0 0.7 0.4 0.4 0.1 0.7 0.4 171 0 171 165 11.8 0 11.9 11.7 07/06/2006 08:00:00 0.4 0.1 1.1 0.4 0.4 0.1 0.7 0.4 0.4 0.1 1.1 0.4 205 14 217 165 11.9 0 12.2 11.7 07/06/2006 08:10:00 0.5 0.3 1.5 0.4 0.4 0.2 1.1 0.4 0.9 0.4 1.5 0.4 175 16 204 165 11.9 0 12.2 11.7 07/06/2006 08:20:00 0.4 0 0.7 0.4 0.4 0 0.4 0.4 0.5 0.2 1.5 0.4 165 0 165 165 11.9 0 11.9 11.7 07/06/2006 08:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0.1 0.7 0.4 165 0 165 165 11.9 0 11.9 11.7 07/06/2006 08:40:00 0.4 0 0.7 0.4 0.4 0 0.7 0.4 0.4 0.1 1.1 0.4 163 4 165 165 12 0 12.2 11.9 07/06/2006 08:50:00 0.4 0.1 1.1 0.4 0.4 0.1 1.1 0.4 0.6 0.3 1.5 0.4 175 11 165 165 12.1 0 12.5 11.9 07/06/2006 09:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 165 0 165 165 12.1 0 12.2 11.9 07/06/2006 09:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 165 0 165 165 12.3 0.1 12.5 11.9 07/06/2006 09:20:00 0.4 0.2 1.1 0.4 0.4 0.1 1.1 0.4 0.7 0.4 1.9 0.4 160 4 164 165 12.4 0 12.5 12.2 07/06/2006 09:30:00 0.4 0.3 1.9 0.4 0.4 0.2 1.9 0.4 0.7 0.4 1.9 0.4 155 4 150 165 12.3 0 12.5 11.9 07/06/2006 09:40:00 0.5 0.3 1.5 0.4 0.5 0.3 1.5 0.4 0.8 0.5 1.9 0.4 154 5 152 165 12 0 12.2 11.9 07/06/2006 09:50:00 0.5 0.2 1.5 0.4 0.4 0.2 1.1 0.4 0.7 0.3 1.5 0.4 158 8 159 165 12 0 12.2 11.9 07/06/2006 10:00:00 0.6 0.3 1.5 0.4 0.6 0.4 1.5 0.4 1 0.5 2.3 0.4 135 6 135 165 12.1 0 12.2 11.9 07/06/2006 10:10:00 0.7 0.4 1.9 0.4 0.7 0.4 2.3 0.4 1.1 0.5 2.6 0.4 145 7 147 165 12.2 0 12.5 11.9 07/06/2006 10:20:00 1.3 0.4 2.3 0.4 1.4 0.4 2.6 0.7 1.8 0.3 2.6 1.1 140 9 137 165 12.1 0 12.2 11.9 07/06/2006 10:30:00 1.4 0.4 2.3 0.4 1.6 0.3 2.6 0.4 1.8 0.3 2.6 1.1 144 7 147 165 12.1 0 12.2 11.9 07/06/2006 10:40:00 1.7 0.4 2.6 0.7 1.9 0.4 2.6 1.1 2.1 0.3 2.6 1.1 149 8 164 165 11.9 0 12.2 11.9 07/06/2006 10:50:00 1.3 0.4 2.6 0.4 1.5 0.4 2.6 0.7 1.8 0.4 2.6 0.7 143 9 153 165 11.8 0.1 11.9 11.7 07/06/2006 11:00:00 0.8 0.4 1.9 0.4 1 0.4 1.9 0.4 1.4 0.3 2.3 0.7 151 7 144 165 11.8 0 11.9 11.7 07/06/2006 11:10:00 0.9 0.4 1.9 0.4 1.1 0.4 2.3 0.4 1.5 0.3 2.3 0.7 139 8 138 165 12.1 0.2 12.5 11.7 07/06/2006 11:20:00 0.8 0.3 1.5 0.4 1 0.4 1.9 0.4 1.5 0.3 2.3 0.7 141 6 149 165 12.2 0 12.5 11.9 07/06/2006 11:30:00 1.2 0.5 2.3 0.4 1.5 0.4 2.6 0.7 1.7 0.4 2.3 1.1 145 5 145 165 12.2 0 12.5 11.9 07/06/2006 11:40:00 0.6 0.3 1.9 0.4 0.9 0.4 1.9 0.4 1.2 0.4 1.9 0.4 148 11 145 165 12.3 0 12.5 11.9 07/06/2006 11:50:00 0.5 0.2 1.5 0.4 0.6 0.4 1.5 0.4 0.8 0.4 2.3 0.4 134 11 141 165 12.3 0 12.5 12.2 07/06/2006 12:00:00 0.4 0.2 1.5 0.4 0.5 0.3 1.9 0.4 0.8 0.4 1.9 0.4 139 11 128 165 12.4 0.1 12.7 11.9 07/06/2006 12:10:00 0.7 0.4 2.3 0.4 0.8 0.5 2.3 0.4 1.1 0.5 2.3 0.4 146 17 168 165 12.5 0 12.7 11.9 07/06/2006 12:20:00 0.5 0.3 1.9 0.4 0.7 0.4 1.9 0.4 0.9 0.5 1.9 0.4 142 12 135 165 12.6 0 12.7 12.2 07/06/2006 12:30:00 0.5 0.3 1.5 0.4 0.8 0.4 1.5 0.4 1 0.5 2.3 0.4 142 7 160 165 12.7 0 13 12.2 07/06/2006 12:40:00 0.8 0.4 1.9 0.4 1.2 0.4 2.3 0.4 1.5 0.3 2.3 0.7 150 6 152 165 12.7 0 13 12.2 07/06/2006 12:50:00 0.4 0.2 1.1 0.4 0.6 0.4 1.5 0.4 0.8 0.5 1.9 0.4 137 4 139 165 12.5 0.1 12.7 11.9 07/06/2006 13:00:00 0.4 0.1 1.1 0.4 0.6 0.3 1.5 0.4 0.7 0.4 1.5 0.4 131 6 135 165 12.6 0 12.7 11.9 07/06/2006 13:10:00 0.4 0.2 1.5 0.4 0.6 0.4 1.9 0.4 0.8 0.5 1.9 0.4 138 0 137 165 12.5 0 12.7 12.5 07/06/2006 13:20:00 0.4 0.2 1.5 0.4 0.7 0.4 1.9 0.4 0.8 0.4 1.5 0.4 131 6 138 165 12.4 0 12.7 12.2 07/06/2006 13:30:00 0.4 0.2 1.5 0.4 0.5 0.3 1.5 0.4 0.6 0.4 1.5 0.4 149 7 159 165 12.4 0 12.5 12.5 07/06/2006 13:40:00 0.4 0.1 0.7 0.4 0.4 0.2 1.5 0.4 0.6 0.4 1.5 0.4 142 11 143 165 12.5 0 12.7 12.5 07/06/2006 13:50:00 0.5 0.3 1.5 0.4 0.7 0.4 1.9 0.4 0.8 0.4 1.9 0.4 124 11 145 165 12.5 0.1 13 12.5 07/06/2006 14:00:00 0.6 0.4 2.3 0.4 0.9 0.5 2.3 0.4 1.3 0.5 2.3 0.4 136 9 152 165 12.3 0 12.5 12.2 07/06/2006 14:10:00 0.7 0.4 1.9 0.4 1 0.5 2.3 0.4 1.2 0.4 2.3 0.4 132 12 140 165 12.4 0 12.5 12.2 07/06/2006 14:20:00 1.2 0.5 2.3 0.4 1.6 0.4 2.6 0.4 1.5 0.5 2.6 0.4 131 10 123 165 12.4 0 12.7 12.2 07/06/2006 14:30:00 1.2 0.5 2.6 0.4 1.6 0.5 2.6 0.4 1.6 0.4 2.6 0.4 135 12 133 165 12.4 0.1 12.7 12.2 07/06/2006 14:40:00 1 0.4 2.3 0.4 1.5 0.4 2.6 0.7 1.7 0.4 2.3 0.7 133 7 121 165 12.4 0 12.5 12.2 07/06/2006 14:50:00 0.7 0.4 1.5 0.4 1.3 0.4 2.3 0.4 1.4 0.5 2.3 0.4 132 16 141 165 12.5 0 12.7 12.2 07/06/2006 15:00:00 0.6 0.4 1.9 0.4 1.1 0.5 2.3 0.4 1.2 0.4 2.3 0.4 132 14 139 165 12.6 0 12.7 12.5 07/06/2006 15:10:00 0.5 0.3 1.5 0.4 0.8 0.4 1.9 0.4 0.9 0.5 2.3 0.4 129 11 125 165 12.7 0 13 12.5 07/06/2006 15:20:00 0.4 0.2 1.1 0.4 0.6 0.4 1.9 0.4 0.9 0.4 1.9 0.4 135 7 142 165 12.7 0 13 12.2 07/06/2006 15:30:00 0.6 0.4 2.3 0.4 0.9 0.5 2.6 0.4 1.1 0.4 1.9 0.4 151 12 157 165 12.7 0 13 12.2 07/06/2006 15:40:00 0.4 0.1 1.1 0.4 0.4 0.2 1.5 0.4 0.7 0.4 1.9 0.4 155 7 169 165 12.7 0.1 13 12.2 07/06/2006 15:50:00 0.6 0.4 1.9 0.4 0.8 0.5 1.9 0.4 1.1 0.5 2.6 0.4 172 9 169 165 12.9 0.1 13 12.5 07/06/2006 16:00:00 0.7 0.5 2.3 0.4 0.9 0.5 2.3 0.4 1.3 0.5 2.6 0.4 170 10 164 165 13.1 0 13.3 12.5 07/06/2006 16:10:00 0.5 0.3 1.9 0.4 0.8 0.5 1.9 0.4 1 0.5 2.3 0.4 160 8 166 165 12.9 0.1 13.3 12.5 07/06/2006 16:20:00 0.8 0.5 2.3 0.4 1.1 0.6 2.3 0.4 1.4 0.6 2.6 0.4 151 9 149 165 12.9 0.1 13 12.2 07/06/2006 16:30:00 0.9 0.4 1.9 0.4 1.4 0.3 2.3 0.7 1.5 0.3 2.6 0.7 153 9 132 165 12.9 0.1 13.3 12.2 07/06/2006 16:40:00 0.6 0.3 1.5 0.4 1.2 0.3 1.9 0.7 1.4 0.3 2.3 0.7 153 5 153 165 12.7 0 13.3 12.2 07/06/2006 16:50:00 0.9 0.5 2.3 0.4 1.4 0.4 2.6 0.4 1.6 0.4 3 0.7 148 9 139 165 12.8 0.1 13 12.2 07/06/2006 17:00:00 0.4 0.2 1.5 0.4 0.7 0.4 1.9 0.4 1 0.4 2.3 0.4 141 8 130 165 12.8 0.1 13 12.5 07/06/2006 17:10:00 0.5 0.3 1.9 0.4 0.7 0.4 1.9 0.4 1.3 0.4 2.3 0.4 141 6 138 165 12.8 0.1 13 12.5 07/06/2006 17:20:00 0.5 0.3 1.9 0.4 0.8 0.5 1.9 0.4 1.1 0.4 2.6 0.4 140 4 126 165 12.8 0.1 13 12.2 07/06/2006 17:30:00 0.7 0.4 1.5 0.4 1.3 0.2 1.9 0.7 1.5 0.3 2.3 0.7 132 3 129 165 12.8 0 13 12.2 07/06/2006 17:40:00 1.1 0.4 1.9 0.4 1.6 0.3 2.3 1.1 1.6 0.3 2.6 0.7 127 2 130 165 12.9 0 13 12.7 07/06/2006 17:50:00 1.2 0.4 2.3 0.4 1.8 0.3 2.3 0.7 1.8 0.3 2.6 1.1 123 6 119 165 12.9 0 13 12.7 07/06/2006 18:00:00 1.4 0.5 2.6 0.4 1.9 0.3 2.6 1.1 1.9 0.3 2.6 1.1 117 5 112 165 12.9 0 13 12.7 07/06/2006 18:10:00 1.2 0.5 2.6 0.4 1.8 0.4 3 1.1 1.9 0.3 2.6 1.1 110 3 112 165 12.9 0 13 12.7 07/06/2006 18:20:00 0.6 0.3 1.5 0.4 1.2 0.5 2.3 0.4 1.2 0.5 2.3 0.4 107 6 111 165 12.8 0 13 12.7 07/06/2006 18:30:00 0.4 0 0.4 0.4 0.5 0.3 1.5 0.4 0.5 0.3 1.5 0.4 89 7 165 165 12.9 0 13 12.7 07/06/2006 18:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0.1 0.7 0.4 69 9 165 165 13.1 0 13.3 13 07/06/2006 18:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0.2 1.1 0.4 22 13 165 165 13.3 0 13.5 13.3 07/06/2006 19:00:00 0.4 0 0.4 0.4 0.4 0 0.7 0.4 0.4 0.2 1.1 0.4 9 7 165 165 13.3 0 13.5 13.3 07/06/2006 19:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 3 0 165 165 13.3 0 13.5 13.3 07/06/2006 19:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0.1 1.1 0.4 3 0 165 165 13.3 0 13.5 13.3 07/06/2006 19:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0.1 1.1 0.4 3 0 165 165 13.3 0 13.5 13.3 07/06/2006 19:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.7 0.4 3 0 165 165 13.3 0 13.5 13.3 07/06/2006 19:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 3 0 165 165 13.3 0 13.5 13.3 07/06/2006 20:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 3 0 165 165 13.3 0 13.5 13.3 07/06/2006 20:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 3 0 165 165 13.3 0 13.5 13.3 07/06/2006 20:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 32 35 165 165 13.1 0.1 13.5 12.7 07/06/2006 20:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 74 0 165 165 12.9 0 13 12.7 07/06/2006 20:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 45 39 165 165 12.9 0 13 12.7 07/06/2006 20:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.7 0.4 337 5 165 165 12.9 0.1 13 12.5 07/06/2006 21:00:00 0.4 0.1 0.7 0.4 0.7 0.3 1.1 0.4 0.9 0.3 1.5 0.4 307 2 307 165 12.9 0.1 13 12.5 07/06/2006 21:10:00 0.8 0.2 1.1 0.4 1.2 0.2 1.5 0.7 1.3 0.2 1.5 1.1 307 0 307 165 12.8 0.1 13 12.2 07/06/2006 21:20:00 0.5 0.2 1.1 0.4 1.1 0.1 1.5 0.7 1.2 0.2 1.5 0.7 308 0 307 165 12.8 0.1 13 12.2 07/06/2006 21:30:00 0.4 0 0.4 0.4 0.5 0.2 1.1 0.4 0.7 0.2 1.1 0.4 308 0 165 165 12.9 0.1 13 12.5 07/06/2006 21:40:00 0.4 0 0.4 0.4 0.4 0.1 0.7 0.4 0.4 0.2 1.1 0.4 308 0 165 165 12.9 0.1 13 12.5 07/06/2006 21:50:00 0.4 0 0.4 0.4 0.4 0.2 1.1 0.4 0.7 0.3 1.5 0.4 318 8 165 165 12.8 0 13 12.2 07/06/2006 22:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0.1 0.7 0.4 325 0 165 165 12.5 0 12.7 11.9 07/06/2006 22:10:00 0.4 0 0.4 0.4 0.4 0 0.7 0.4 0.4 0.1 1.1 0.4 44 49 165 165 12.7 0 12.7 12.5 07/06/2006 22:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 74 0 165 165 12.6 0 13 12.5 07/06/2006 22:30:00 0.4 0 0.4 0.4 0.4 0.1 0.7 0.4 0.4 0.1 1.1 0.4 74 0 165 165 12.4 0 12.7 12.2 07/06/2006 22:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.7 0.4 68 11 165 165 12.5 0 12.7 12.2 07/06/2006 22:50:00 0.4 0 0.4 0.4 0.4 0 0.7 0.4 0.7 0.2 1.1 0.4 15 12 165 165 12.3 0 12.5 11.9 07/06/2006 23:00:00 0.4 0 0.7 0.4 0.4 0.2 1.1 0.4 0.4 0.1 1.1 0.4 23 5 17 165 12.2 0 12.5 11.9 07/06/2006 23:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 47 19 165 165 12.3 0.1 12.5 11.9 07/06/2006 23:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 67 0 165 165 12.4 0 12.5 12.2 07/06/2006 23:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.7 0.4 99 29 165 165 12.4 0 12.7 12.2 07/06/2006 23:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 130 0 165 165 12.3 0 12.7 11.9 07/06/2006 23:50:00 0.4 0 0.4 0.4 0.4 0 0.7 0.4 0.4 0.1 1.1 0.4 130 0 165 165 12.3 0.1 12.5 11.9 07/07/2006 00:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.5 0.2 1.1 0.4 162 8 165 165 12.4 0 12.5 12.2 07/07/2006 00:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 165 0 165 165 12.3 0 12.5 12.2 07/07/2006 00:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.5 0.2 1.1 0.4 165 0 165 165 12.3 0 12.5 12.2 07/07/2006 00:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0.2 1.1 0.4 165 0 165 165 12.3 0.1 12.5 11.9 07/07/2006 00:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 165 0 165 165 12.3 0 12.5 11.9 07/07/2006 00:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 165 0 165 165 12.5 0 12.7 12.2 07/07/2006 01:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 165 0 165 165 12.5 0 12.7 12.2 07/07/2006 01:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 165 0 165 165 12.5 0 12.7 12.2 07/07/2006 01:20:00 0.4 0.1 1.1 0.4 0.6 0.4 1.5 0.4 0.6 0.4 1.5 0.4 122 12 114 165 12.3 0.1 12.7 11.9 07/07/2006 01:30:00 0.4 0 0.4 0.4 0.6 0.3 1.5 0.4 0.7 0.3 1.5 0.4 93 9 165 165 12.3 0.1 12.7 11.9 07/07/2006 01:40:00 0.4 0 0.4 0.4 0.4 0.2 1.5 0.4 0.5 0.3 1.5 0.4 88 0 165 165 12.3 0.1 12.7 11.9 07/07/2006 01:50:00 0.8 0.3 1.1 0.4 1.5 0.2 1.9 1.1 1.4 0.3 2.3 0.7 107 8 92 165 12.1 0.1 12.5 11.7 07/07/2006 02:00:00 0.4 0.1 1.1 0.4 0.8 0.4 1.5 0.4 0.8 0.4 1.5 0.4 114 0 115 165 12 0 12.2 11.7 07/07/2006 02:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.5 0.2 1.1 0.4 125 10 165 165 11.9 0.1 12.5 11.7 07/07/2006 02:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 139 5 165 165 11.9 0.1 12.2 11.7 07/07/2006 02:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 145 0 165 165 11.7 0.2 12.2 11.4 07/07/2006 02:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 145 0 165 165 11.8 0.1 11.9 11.7 07/07/2006 02:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 145 0 165 165 11.9 0.1 11.9 11.4 07/07/2006 03:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 145 0 165 165 11.9 0.1 12.2 11.7 07/07/2006 03:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 145 0 165 165 11.9 0 12.2 11.7 07/07/2006 03:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 145 0 165 165 11.9 0.1 12.2 11.4 07/07/2006 03:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 145 0 165 165 11.9 0.1 12.2 11.4 07/07/2006 03:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 145 0 165 165 11.9 0.1 12.2 11.4 07/07/2006 03:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 145 0 165 165 11.9 0.1 12.2 11.4 07/07/2006 04:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 145 0 165 165 11.9 0 12.2 11.4 07/07/2006 04:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 145 0 165 165 11.9 0 12.5 11.4 07/07/2006 04:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.7 0.4 145 0 165 165 11.9 0.1 12.2 11.4 07/07/2006 04:30:00 0.4 0 0.4 0.4 0.4 0.1 1.1 0.4 1 0.2 1.5 0.4 205 82 165 165 11.7 0.2 11.9 11.4 07/07/2006 04:40:00 0.4 0 0.4 0.4 0.5 0.2 1.1 0.4 1.1 0.2 1.5 0.7 332 8 165 165 11.6 0.1 12.2 11.1 07/07/2006 04:50:00 0.4 0 0.4 0.4 0.4 0 0.7 0.4 0.6 0.3 1.5 0.4 340 0 165 165 11.7 0.1 11.9 11.4 07/07/2006 05:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 340 0 165 165 11.7 0.2 11.9 11.4 07/07/2006 05:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 289 21 165 165 11.7 0.1 11.9 11.4 07/07/2006 05:20:00 0.7 0.4 1.5 0.4 0.9 0.4 1.5 0.4 0.7 0.4 1.5 0.4 230 10 216 165 11.7 0.2 11.9 11.4 07/07/2006 05:30:00 1.3 0.3 2.3 0.7 1.5 0.2 2.3 0.7 1.5 0.3 2.3 0.7 205 11 186 165 11.8 0.2 12.2 11.4 07/07/2006 05:40:00 1.7 0.2 2.3 0.7 1.8 0.2 2.3 1.1 1.9 0.3 2.3 0.7 183 5 181 165 11.7 0.2 12.5 11.4 07/07/2006 05:50:00 1.8 0.2 2.3 1.1 1.8 0.2 2.3 1.1 2.1 0.2 2.6 1.5 177 2 181 165 11.7 0.2 11.9 11.4 07/07/2006 06:00:00 1.8 0.2 2.3 1.1 1.8 0.2 2.3 1.1 2.1 0.2 2.6 1.5 177 2 179 165 11.7 0.2 11.9 11.4 07/07/2006 06:10:00 1.8 0.4 2.6 1.1 1.9 0.4 2.6 0.7 2.2 0.3 3 1.5 177 5 181 165 11.6 0.3 11.9 11.1 07/07/2006 06:20:00 1.9 0.3 2.6 1.1 2 0.3 2.6 1.1 2.1 0.3 2.6 1.5 194 7 200 165 11.6 0.3 11.9 11.1 07/07/2006 06:30:00 1.9 0.5 3 0.7 2 0.5 3 0.7 2.3 0.5 3.4 1.1 192 10 201 165 11.6 0.3 11.9 11.1 07/07/2006 06:40:00 1.9 0.3 2.6 0.7 2.1 0.3 2.6 0.7 2.3 0.3 3 1.5 203 9 198 165 11.5 0.3 12.2 11.1 07/07/2006 06:50:00 0.9 0.5 1.9 0.4 1.1 0.5 1.9 0.4 1.6 0.4 2.6 0.4 190 11 206 165 11.6 0.3 11.9 11.1 07/07/2006 07:00:00 1.4 0.4 2.3 0.4 1.5 0.4 1.9 0.4 1.7 0.3 2.3 0.7 164 10 163 165 11.7 0.2 11.9 11.4 07/07/2006 07:10:00 1.7 0.4 2.6 0.7 1.8 0.4 2.6 0.7 2 0.3 3 0.7 162 8 158 165 11.7 0.1 11.9 11.4 07/07/2006 07:20:00 2.2 0.3 3 1.5 2.3 0.3 3.4 1.5 2.4 0.3 3 1.5 162 7 160 165 11.7 0.2 12.2 11.4 07/07/2006 07:30:00 2 0.4 3 1.1 2.2 0.4 3 1.1 2.4 0.3 3 1.5 153 8 150 165 11.7 0.2 11.9 11.4 07/07/2006 07:40:00 1.3 0.3 2.3 0.7 1.5 0.3 2.3 0.7 1.9 0.3 2.6 1.1 152 6 155 165 11.7 0.2 12.2 11.4 07/07/2006 07:50:00 0.9 0.4 1.5 0.4 1.1 0.3 1.9 0.4 1.3 0.3 1.9 0.4 165 8 157 165 11.6 0.2 11.9 11.1 07/07/2006 08:00:00 0.7 0.4 1.5 0.4 0.9 0.4 1.5 0.4 1 0.4 1.5 0.4 169 3 171 165 11.7 0.2 12.2 11.4 07/07/2006 08:10:00 1 0.5 1.9 0.4 1.3 0.5 1.9 0.4 1.7 0.3 2.3 0.7 170 4 170 165 11.9 0 12.2 11.7 07/07/2006 08:20:00 1.1 0.4 2.3 0.4 1.2 0.4 2.3 0.4 1.5 0.4 2.6 0.4 176 7 156 165 11.9 0.1 12.2 11.7 07/07/2006 08:30:00 1 0.4 1.5 0.4 1.1 0.4 1.9 0.4 1.1 0.5 1.9 0.4 174 6 177 165 11.9 0.1 12.2 11.7 07/07/2006 08:40:00 0.6 0.3 1.1 0.4 0.7 0.3 1.5 0.4 1.1 0.4 1.9 0.4 164 2 167 165 11.8 0.1 11.9 11.4 07/07/2006 08:50:00 0.4 0 0.7 0.4 0.4 0 0.4 0.4 0.4 0.1 1.1 0.4 165 0 165 165 11.9 0.1 12.2 11.4 07/07/2006 09:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.7 0.4 165 0 165 165 11.9 0 12.2 11.7 07/07/2006 09:10:00 0.4 0 0.7 0.4 0.4 0 0.4 0.4 0.6 0.3 1.5 0.4 150 8 135 165 12.2 0 12.5 11.9 07/07/2006 09:20:00 0.4 0 0.7 0.4 0.4 0 0.4 0.4 0.4 0.2 1.5 0.4 133 2 129 165 12.3 0 12.5 11.9 07/07/2006 09:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 134 0 165 165 12.4 0 12.7 12.2 07/07/2006 09:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 130 0 165 165 12.7 0.1 13 12.2 07/07/2006 09:50:00 0.4 0 0.7 0.4 0.4 0 0.7 0.4 0.5 0.3 1.5 0.4 132 5 142 165 12.6 0 13 12.2 07/07/2006 10:00:00 0.9 0.4 1.9 0.4 0.9 0.5 1.9 0.4 1.4 0.4 2.3 0.7 145 6 159 165 12.5 0 12.7 11.9 07/07/2006 10:10:00 1.6 0.4 2.6 0.7 1.6 0.4 2.6 0.7 2.1 0.3 3 1.5 131 9 121 165 12 0.1 12.5 11.7 07/07/2006 10:20:00 1.1 0.5 2.3 0.4 1.1 0.6 2.3 0.4 1.7 0.5 3 0.4 140 21 121 165 11.9 0.1 12.2 11.4 07/07/2006 10:30:00 0.5 0.3 1.5 0.4 0.5 0.3 1.5 0.4 0.8 0.5 1.9 0.4 142 24 179 165 11.9 0.1 12.5 11.4 07/07/2006 10:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 222 21 165 165 12.5 0.3 13 11.9 07/07/2006 10:50:00 0.4 0.1 1.5 0.4 0.4 0.1 1.1 0.4 0.5 0.4 1.9 0.4 356 86 145 165 13.3 0.1 13.5 13 07/07/2006 11:00:00 0.4 0.2 1.5 0.4 0.4 0.1 1.1 0.4 0.6 0.4 1.9 0.4 155 5 157 165 12.7 0 13.3 12.5 07/07/2006 11:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.7 0.4 184 30 165 165 12.9 0.1 13 12.5 07/07/2006 11:20:00 0.4 0.1 0.7 0.4 0.4 0.1 0.7 0.4 0.4 0.1 1.1 0.4 245 22 254 165 13.3 0.1 13.5 13 07/07/2006 11:30:00 0.5 0.2 1.5 0.4 0.4 0.2 1.5 0.4 0.6 0.3 1.5 0.4 167 9 170 165 13.1 0.1 13.5 12.7 07/07/2006 11:40:00 0.6 0.4 1.9 0.4 0.5 0.3 1.9 0.4 0.7 0.5 1.9 0.4 179 7 192 165 13.2 0 13.3 12.7 07/07/2006 11:50:00 1 0.4 1.9 0.4 0.8 0.4 1.9 0.4 1.3 0.5 2.3 0.4 167 13 164 165 13.2 0 13.3 12.7 07/07/2006 12:00:00 0.5 0.2 1.5 0.4 0.4 0.2 1.5 0.4 0.7 0.4 1.9 0.4 144 3 139 165 13.1 0 13.3 13 07/07/2006 12:10:00 0.5 0.2 1.1 0.4 0.4 0.1 1.1 0.4 0.5 0.3 1.5 0.4 148 3 148 165 12.9 0 13.3 12.7 07/07/2006 12:20:00 0.4 0.1 1.5 0.4 0.4 0.1 1.1 0.4 0.4 0 0.7 0.4 135 0 135 165 13.1 0 13.3 12.7 07/07/2006 12:30:00 1.6 0.5 2.6 0.4 1.6 0.5 2.6 0.4 1.8 0.5 3 0.4 119 6 124 165 13.3 0 13.5 13 07/07/2006 12:40:00 2.1 0.4 3 1.1 2.2 0.3 3 1.5 2.4 0.3 3.4 1.9 104 4 107 165 12.9 0 13.3 12.7 07/07/2006 12:50:00 1.7 0.3 2.3 0.7 1.9 0.3 2.6 1.1 2.1 0.3 3 1.5 102 3 102 165 12.8 0 13 12.5 07/07/2006 13:00:00 1.8 0.3 3 0.7 2 0.3 3 1.1 2.2 0.3 3 1.5 94 5 103 165 12.7 0 13 12.5 07/07/2006 13:10:00 1.9 0.3 2.6 1.1 2.1 0.3 2.6 1.1 2.3 0.3 3 1.5 97 6 92 165 12.3 0 12.7 11.9 07/07/2006 13:20:00 1.9 0.4 3 1.1 2.1 0.4 3 1.1 2.2 0.3 3 1.5 98 8 91 165 12.3 0 12.5 12.2 07/07/2006 13:30:00 2.2 0.5 3.4 0.7 2.4 0.5 3.4 1.1 2.6 0.4 3.4 1.1 112 10 123 165 12.4 0 12.7 12.2 07/07/2006 13:40:00 2.7 0.3 3.4 1.9 2.8 0.3 3.4 2.3 2.9 0.3 3.8 2.3 131 8 135 165 12.3 0 12.5 12.2 07/07/2006 13:50:00 2.8 0.4 4.2 1.1 2.8 0.4 4.2 1.5 3.1 0.3 3.8 2.3 148 9 153 165 12.4 0 12.7 12.2 07/07/2006 14:00:00 3.1 0.5 4.2 1.5 3.1 0.5 4.2 1.5 3.4 0.4 4.6 2.3 146 12 146 165 12.2 0 12.5 11.9 07/07/2006 14:10:00 3.7 0.5 4.9 2.3 3.6 0.5 4.9 2.3 3.9 0.6 5.7 2.3 156 10 159 165 12 0 12.2 11.7 07/07/2006 14:20:00 3.8 0.4 4.9 3 3.7 0.4 4.9 2.6 3.9 0.4 4.9 2.6 150 7 156 165 11.9 0.1 12.2 11.4 07/07/2006 14:30:00 3.1 0.5 4.6 1.9 3 0.5 4.2 1.9 3.2 0.5 4.9 1.9 145 13 141 165 12 0.1 12.5 11.4 07/07/2006 14:40:00 2.5 0.5 4.2 1.1 2.4 0.6 3.8 0.7 2.7 0.6 3.8 0.7 139 15 142 165 12.2 0.2 12.5 11.7 07/07/2006 14:50:00 2.4 0.5 3.4 0.4 2.2 0.5 3.4 0.4 2.8 0.5 4.2 1.5 152 13 159 165 12.3 0.1 12.5 11.9 07/07/2006 15:00:00 2.3 0.5 3.4 1.1 2.3 0.6 3.4 0.7 2.6 0.5 3.8 1.1 165 8 155 165 12.7 0.1 13 12.2 07/07/2006 15:10:00 1.9 0.5 3.4 0.7 1.9 0.5 3.4 0.4 2.4 0.4 3.4 1.5 168 10 153 165 12.9 0.2 13.3 12.5 07/07/2006 15:20:00 2.4 0.5 3.8 1.1 2.4 0.5 3.8 0.7 2.8 0.5 4.2 1.5 173 10 200 165 13.1 0 13.3 13 07/07/2006 15:30:00 2.4 0.6 4.2 0.4 2.4 0.7 3.8 0.4 2.7 0.6 3.8 0.7 162 13 157 165 12.9 0 13.3 12.7 07/07/2006 15:40:00 2.5 0.4 3.4 1.5 2.4 0.4 3.4 1.5 2.9 0.4 3.8 1.9 138 14 122 165 12.9 0 13.3 12.7 07/07/2006 15:50:00 3.4 0.4 4.6 2.6 3.3 0.4 4.6 2.6 3.6 0.4 4.6 2.6 123 7 109 165 12.5 0.2 13 12.2 07/07/2006 16:00:00 3.6 0.3 4.6 2.6 3.4 0.4 4.2 2.3 3.6 0.3 4.6 2.6 125 9 122 165 12.2 0 12.5 11.9 07/07/2006 16:10:00 3.5 0.6 4.9 2.3 3.3 0.6 4.6 1.9 3.7 0.6 5.3 2.3 145 12 144 165 12.1 0 12.5 11.7 07/07/2006 16:20:00 2.4 0.4 3.8 1.5 2.1 0.5 3.8 1.1 2.4 0.5 4.2 1.1 140 15 153 165 12.1 0 12.2 11.7 07/07/2006 16:30:00 2.6 0.4 3.8 1.9 2.5 0.5 3.4 1.5 2.8 0.4 3.8 1.5 135 10 122 165 12.2 0 12.5 11.9 07/07/2006 16:40:00 2.3 0.5 3.4 0.7 2.2 0.5 3.4 0.7 2.5 0.5 4.2 1.5 134 9 136 165 12.1 0.1 12.5 11.9 07/07/2006 16:50:00 2.2 0.3 3 1.5 2.1 0.3 3 1.5 2.3 0.3 3 1.5 133 5 124 165 12.1 0 12.5 11.9 07/07/2006 17:00:00 1.5 0.4 2.3 0.4 1.4 0.4 2.3 0.4 1.7 0.4 2.3 0.7 138 7 130 165 12.2 0 12.5 12.2 07/07/2006 17:10:00 1.3 0.4 2.3 0.4 1.3 0.5 2.6 0.4 1.8 0.4 2.6 0.7 112 8 119 165 12.3 0 12.5 12.2 07/07/2006 17:20:00 0.4 0.2 1.5 0.4 0.4 0.3 1.9 0.4 0.8 0.5 2.3 0.4 104 3 105 165 12.5 0 12.7 12.5 07/07/2006 17:30:00 0.4 0.2 1.1 0.4 0.4 0.1 1.1 0.4 0.8 0.4 1.9 0.4 102 8 95 165 12.7 0 12.7 12.5 07/07/2006 17:40:00 0.5 0.3 1.5 0.4 0.4 0.2 1.1 0.4 1 0.4 1.9 0.4 120 9 118 165 12.7 0 12.7 12.5 07/07/2006 17:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0.2 1.1 0.4 151 1 165 165 12.7 0 12.7 12.5 07/07/2006 18:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0.1 1.1 0.4 153 0 165 165 12.7 0 12.7 12.5 07/07/2006 18:10:00 0.4 0.2 1.5 0.4 0.4 0.1 1.1 0.4 0.7 0.4 1.9 0.4 166 9 166 165 12.7 0 13 12.7 07/07/2006 18:20:00 1.2 0.4 2.3 0.4 0.9 0.5 2.3 0.4 1.6 0.4 2.6 0.7 172 7 169 165 12.6 0 12.7 12.5 07/07/2006 18:30:00 0.6 0.4 1.9 0.4 0.5 0.3 1.5 0.4 1.3 0.4 1.9 0.4 172 8 169 165 12.7 0 12.7 12.5 07/07/2006 18:40:00 0.6 0.3 1.5 0.4 0.5 0.3 1.9 0.4 1 0.5 1.9 0.4 171 9 172 165 12.7 0 12.7 12.2 07/07/2006 18:50:00 0.9 0.4 1.9 0.4 0.8 0.4 1.9 0.4 1.1 0.5 1.9 0.4 167 22 165 165 12.6 0 12.7 12.2 07/07/2006 19:00:00 0.8 0.5 2.3 0.4 0.8 0.5 2.3 0.4 1.2 0.6 2.6 0.4 168 21 165 165 12.6 0 12.7 12.2 07/07/2006 19:10:00 0.6 0.3 1.5 0.4 0.6 0.3 1.5 0.4 1.3 0.3 2.3 0.4 154 4 151 165 12.4 0.1 12.7 11.9 07/07/2006 19:20:00 0.9 0.4 2.3 0.4 1 0.4 2.3 0.4 1.4 0.3 2.3 0.4 173 14 176 165 12.3 0 12.5 11.7 07/07/2006 19:30:00 2.4 0.5 3.4 1.5 2.5 0.5 3.4 1.5 2.6 0.5 3.8 1.5 200 5 208 165 12.1 0 12.5 11.7 07/07/2006 19:40:00 2.1 0.5 3.4 0.7 2.2 0.5 3.4 0.7 2.4 0.5 3.4 1.5 195 10 205 165 11.9 0 12.2 11.7 07/07/2006 19:50:00 1.4 0.5 2.3 0.4 1.5 0.5 2.6 0.4 1.9 0.4 2.6 0.7 194 7 197 165 11.9 0 12.2 11.7 07/07/2006 20:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.8 0.4 1.9 0.4 184 2 165 165 11.9 0 12.2 11.7 07/07/2006 20:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 182 0 165 165 11.9 0 12.2 11.7 07/07/2006 20:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 182 0 165 165 12 0 12.2 11.7 07/07/2006 20:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 182 0 165 165 12.1 0 12.2 11.7 07/07/2006 20:40:00 0.4 0.1 1.1 0.4 0.4 0.1 1.1 0.4 0.5 0.3 1.5 0.4 230 72 315 165 12.1 0 12.5 11.9 07/07/2006 20:50:00 0.6 0.3 1.5 0.4 0.6 0.3 1.5 0.4 1.2 0.2 1.5 0.4 323 4 328 165 12.2 0.1 12.5 11.9 07/07/2006 21:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.5 0.2 1.1 0.4 326 0 165 165 12.3 0 12.5 11.9 07/07/2006 21:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 326 0 165 165 12.2 0 12.5 11.9 07/07/2006 21:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 326 0 165 165 12.1 0 12.2 11.9 07/07/2006 21:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 326 0 165 165 12.1 0 12.5 11.9 07/07/2006 21:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 326 0 165 165 12.1 0 12.5 11.7 07/07/2006 21:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 304 35 165 165 12 0 12.2 11.7 07/07/2006 22:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.7 0.4 248 0 165 165 11.9 0.1 12.2 11.7 07/07/2006 22:10:00 0.4 0.1 1.1 0.4 0.4 0 0.4 0.4 0.6 0.4 1.5 0.4 274 32 315 165 11.9 0.1 12.2 11.7 07/07/2006 22:20:00 0.7 0.2 1.1 0.4 0.6 0.3 1.1 0.4 1.2 0.2 1.5 1.1 329 6 316 165 11.9 0.1 12.2 11.4 07/07/2006 22:30:00 0.5 0.2 1.1 0.4 0.4 0.2 1.1 0.4 0.9 0.4 1.5 0.4 1 16 341 165 11.9 0.1 12.2 11.4 07/07/2006 22:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0.1 0.7 0.4 21 0 165 165 11.9 0.1 12.5 11.4 07/07/2006 22:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.7 0.4 21 0 165 165 11.8 0.2 11.9 11.4 07/07/2006 23:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 7 165 165 11.8 0.1 11.9 11.4 07/07/2006 23:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 38 0 165 165 11.8 0.1 11.9 11.4 07/07/2006 23:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 38 0 165 165 11.7 0.2 11.9 11.4 07/07/2006 23:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 38 0 165 165 11.6 0.2 11.9 11.1 07/07/2006 23:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 38 0 165 165 11.6 0.1 11.9 11.1 07/07/2006 23:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 80 58 165 165 11.5 0 11.7 11.1 07/08/2006 00:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 162 0 165 165 11.4 0 11.7 11.1 07/08/2006 00:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 162 0 165 165 11.3 0.1 11.7 10.9 07/08/2006 00:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.7 0.4 200 27 165 165 11.3 0.1 11.7 10.9 07/08/2006 00:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 252 10 165 165 11.3 0 11.7 10.9 07/08/2006 00:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 257 0 165 165 11.3 0.1 11.7 10.9 07/08/2006 00:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 256 0 165 165 11.3 0 11.9 10.9 07/08/2006 01:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 249 10 165 165 11.3 0 11.4 10.9 07/08/2006 01:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 197 0 165 165 11.3 0 11.7 11.1 07/08/2006 01:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 196 0 165 165 11.3 0 11.4 11.1 07/08/2006 01:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 196 0 165 165 11.3 0 11.4 11.1 07/08/2006 01:40:00 0.4 0.1 1.1 0.4 0.4 0.1 1.1 0.4 0.4 0.2 1.1 0.4 233 32 259 165 11.2 0 11.7 11.1 07/08/2006 01:50:00 0.8 0.5 2.3 0.4 1 0.6 2.3 0.4 0.8 0.5 1.9 0.4 266 11 277 165 11.1 0 11.4 10.9 07/08/2006 02:00:00 0.5 0.2 1.5 0.4 0.7 0.4 1.9 0.4 0.8 0.4 1.9 0.4 260 10 268 165 11.1 0 11.4 10.9 07/08/2006 02:10:00 0.4 0.1 1.1 0.4 0.4 0.2 1.5 0.4 0.4 0.2 1.5 0.4 245 22 266 165 11.1 0 11.4 10.9 07/08/2006 02:20:00 0.4 0 0.7 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 246 0 247 165 11.1 0 11.4 10.9 07/08/2006 02:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 246 0 165 165 11.1 0 11.7 10.9 07/08/2006 02:40:00 0.4 0.1 1.1 0.4 0.4 0.1 1.1 0.4 0.4 0.2 1.5 0.4 192 24 182 165 11.1 0 11.4 10.9 07/08/2006 02:50:00 0.4 0 0.7 0.4 0.4 0.1 1.1 0.4 0.4 0.2 1.5 0.4 151 43 305 165 10.9 0 11.1 10.6 07/08/2006 03:00:00 0.4 0.2 1.5 0.4 0.4 0.2 1.1 0.4 0.7 0.3 1.5 0.4 153 12 160 165 10.9 0 11.1 10.9 07/08/2006 03:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.5 0.2 1.1 0.4 142 0 165 165 10.8 0 11.1 10.6 07/08/2006 03:20:00 0.4 0.1 1.1 0.4 0.4 0.2 1.9 0.4 0.5 0.3 1.5 0.4 148 8 159 165 10.8 0 11.1 10.6 07/08/2006 03:30:00 0.5 0.3 1.5 0.4 0.5 0.4 1.9 0.4 0.5 0.3 1.9 0.4 210 43 252 165 10.8 0 11.1 10.6 07/08/2006 03:40:00 1.1 0.4 2.3 0.4 1.5 0.4 2.3 0.4 1.1 0.4 2.3 0.4 256 10 241 165 10.8 0 11.1 10.6 07/08/2006 03:50:00 1.1 0.4 1.9 0.4 1.4 0.4 2.3 0.4 1.3 0.4 1.9 0.4 250 11 249 165 10.8 0 11.1 10.6 07/08/2006 04:00:00 0.6 0.5 2.3 0.4 0.6 0.5 2.3 0.4 0.5 0.3 1.5 0.4 198 24 229 165 10.7 0 10.9 10.3 07/08/2006 04:10:00 2 0.9 3.4 0.4 2.1 1 3.8 0.4 1.7 0.9 3.4 0.4 224 22 242 165 10.7 0 10.9 10.3 07/08/2006 04:20:00 2.2 0.4 3 0.7 2.9 0.4 3.4 1.5 2.9 0.4 3.4 0.7 256 6 251 165 10.7 0 10.9 10.6 07/08/2006 04:30:00 2.5 0.4 3 1.1 2.7 0.3 3.4 1.5 2.6 0.4 3.4 1.5 269 4 267 165 10.9 0 11.1 10.9 07/08/2006 04:40:00 2.9 0.2 3.4 2.6 3 0.2 3.4 2.3 3.1 0.2 3.4 2.6 283 2 281 165 11 0 11.7 10.9 07/08/2006 04:50:00 1.6 0.6 2.6 0.4 1.8 0.6 2.6 0.4 1.9 0.6 3 0.4 264 15 279 165 11.1 0 11.1 10.6 07/08/2006 05:00:00 0.6 0.4 1.9 0.4 0.5 0.3 1.9 0.4 0.6 0.3 1.5 0.4 186 17 214 165 10.9 0 11.1 10.6 07/08/2006 05:10:00 0.4 0.2 1.5 0.4 0.4 0.1 1.1 0.4 0.4 0 0.4 0.4 211 4 213 165 10.9 0 11.1 10.9 07/08/2006 05:20:00 0.6 0.4 1.9 0.4 0.6 0.4 1.9 0.4 0.5 0.4 1.5 0.4 238 35 279 165 11 0 11.1 10.9 07/08/2006 05:30:00 1.4 0.2 2.3 0.7 1.4 0.3 2.3 0.7 1.3 0.3 1.9 0.4 284 2 284 165 11.1 0 11.4 10.6 07/08/2006 05:40:00 0.7 0.4 1.9 0.4 0.6 0.4 1.9 0.4 0.5 0.2 1.1 0.4 300 2 297 165 11.3 0 11.4 11.1 07/08/2006 05:50:00 0.4 0.1 1.1 0.4 0.4 0 0.4 0.4 0.4 0.1 1.1 0.4 301 0 301 165 11.3 0 11.9 11.1 07/08/2006 06:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 266 56 165 165 11.3 0 11.7 11.1 07/08/2006 06:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 175 0 165 165 11.3 0 11.7 11.1 07/08/2006 06:20:00 0.4 0.1 0.7 0.4 0.4 0 0.4 0.4 0.4 0.2 1.1 0.4 175 0 175 165 11.3 0 11.4 11.1 07/08/2006 06:30:00 0.4 0.1 0.7 0.4 0.4 0 0.4 0.4 0.5 0.2 1.1 0.4 175 0 175 165 11.3 0 11.9 11.1 07/08/2006 06:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 175 0 165 165 11.3 0 11.7 11.1 07/08/2006 06:50:00 0.4 0.2 1.1 0.4 0.4 0.1 1.1 0.4 0.5 0.2 1.5 0.4 180 7 185 165 11.4 0 11.7 10.9 07/08/2006 07:00:00 0.4 0.1 1.1 0.4 0.4 0 0.7 0.4 0.4 0.1 1.1 0.4 175 8 196 165 11.5 0 11.9 10.9 07/08/2006 07:10:00 0.6 0.3 1.5 0.4 0.5 0.2 1.5 0.4 0.7 0.3 1.5 0.4 198 13 224 165 11.5 0.1 11.9 11.1 07/08/2006 07:20:00 0.9 0.5 2.3 0.4 0.8 0.5 2.6 0.4 1 0.4 1.9 0.4 182 20 203 165 11.5 0.1 11.7 11.1 07/08/2006 07:30:00 0.6 0.5 2.6 0.4 0.6 0.6 2.6 0.4 0.7 0.5 2.6 0.4 183 23 249 165 11.5 0 11.7 11.1 07/08/2006 07:40:00 0.7 0.5 2.3 0.4 0.6 0.5 2.6 0.4 0.7 0.5 2.6 0.4 194 39 252 165 11.7 0.2 11.9 11.1 07/08/2006 07:50:00 0.6 0.4 2.6 0.4 0.6 0.4 2.6 0.4 0.6 0.3 1.9 0.4 197 27 235 165 11.8 0.1 12.2 11.4 07/08/2006 08:00:00 1.4 0.5 2.6 0.4 1.5 0.6 2.6 0.4 1.5 0.5 2.6 0.4 221 14 228 165 12.1 0 12.2 11.7 07/08/2006 08:10:00 1.7 0.4 3 0.7 1.8 0.4 3 0.7 1.9 0.4 2.6 0.7 216 15 228 165 12.1 0 12.5 11.9 07/08/2006 08:20:00 1.4 0.6 3 0.4 1.5 0.6 3 0.4 1.6 0.6 2.6 0.4 221 15 213 165 12.3 0.1 12.5 11.7 07/08/2006 08:30:00 1.2 0.7 2.6 0.4 1.3 0.7 2.6 0.4 1.4 0.7 3 0.4 218 30 168 165 12.3 0.1 12.5 11.9 07/08/2006 08:40:00 0.7 0.5 3 0.4 0.7 0.5 2.6 0.4 0.7 0.4 1.9 0.4 198 58 339 165 12.4 0 12.5 11.9 07/08/2006 08:50:00 0.6 0.5 2.3 0.4 0.8 0.6 2.6 0.4 0.7 0.6 2.6 0.4 200 32 216 165 12.4 0.1 12.5 11.9 07/08/2006 09:00:00 0.8 0.7 3.4 0.4 0.9 0.9 3.4 0.4 0.8 0.7 3 0.4 199 47 211 165 12.6 0 12.7 12.2 07/08/2006 09:10:00 0.8 0.5 1.9 0.4 0.9 0.5 2.3 0.4 1.2 0.6 2.6 0.4 182 21 173 165 12.3 0 12.7 11.9 07/08/2006 09:20:00 0.5 0.3 1.9 0.4 0.5 0.3 1.9 0.4 0.9 0.4 1.9 0.4 179 15 170 165 12.2 0 12.5 11.9 07/08/2006 09:30:00 0.4 0.1 1.1 0.4 0.4 0.2 1.1 0.4 0.5 0.4 1.9 0.4 195 18 201 165 12.5 0.2 13 11.9 07/08/2006 09:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0.1 0.7 0.4 207 20 165 165 13.1 0 13.3 12.7 07/08/2006 09:50:00 0.5 0.4 1.9 0.4 0.6 0.4 2.3 0.4 0.6 0.5 2.3 0.4 177 56 143 165 13.2 0.1 13.5 12.5 07/08/2006 10:00:00 0.7 0.4 1.9 0.4 0.6 0.4 2.3 0.4 0.7 0.4 2.3 0.4 171 15 184 165 13.1 0 13.3 12.5 07/08/2006 10:10:00 1.5 0.5 2.6 0.4 1.4 0.5 2.6 0.4 1.7 0.5 3 0.4 184 13 185 165 13.2 0 13.3 12.7 07/08/2006 10:20:00 1.5 0.6 3 0.4 1.4 0.7 3 0.4 1.7 0.6 3 0.4 171 15 184 165 13.3 0 13.5 12.7 07/08/2006 10:30:00 0.7 0.5 2.3 0.4 0.7 0.5 2.3 0.4 0.7 0.5 2.3 0.4 170 39 164 165 13.4 0 13.5 12.7 07/08/2006 10:40:00 0.8 0.4 2.3 0.4 0.8 0.4 2.3 0.4 0.8 0.5 2.3 0.4 186 15 186 165 13.6 0.2 14.1 13 07/08/2006 10:50:00 0.9 0.4 2.3 0.4 0.8 0.4 2.3 0.4 1.1 0.5 2.3 0.4 179 15 188 165 13.9 0.1 14.6 13.5 07/08/2006 11:00:00 0.4 0.2 1.5 0.4 0.4 0.2 1.5 0.4 0.5 0.2 1.5 0.4 182 12 178 165 13.7 0 14.1 13.5 07/08/2006 11:10:00 0.6 0.3 1.5 0.4 0.6 0.3 1.5 0.4 0.8 0.4 1.9 0.4 199 29 158 165 13.8 0 14.1 13.5 07/08/2006 11:20:00 0.8 0.6 2.3 0.4 0.8 0.6 2.3 0.4 0.9 0.6 2.3 0.4 141 17 141 165 13.7 0 14.4 13.3 07/08/2006 11:30:00 0.9 0.5 1.9 0.4 0.9 0.5 2.3 0.4 1 0.4 1.9 0.4 103 13 105 165 13.4 0.2 13.8 13 07/08/2006 11:40:00 1.4 0.5 2.3 0.4 1.5 0.6 2.6 0.4 1.7 0.4 2.6 0.4 109 16 81 165 13.3 0.2 13.8 13 07/08/2006 11:50:00 2 0.5 3 0.4 2.1 0.5 3.4 0.7 2.4 0.4 3.4 1.5 115 15 118 165 14 0.3 14.6 13.3 07/08/2006 12:00:00 1.8 0.6 3.4 0.7 1.8 0.6 3 0.4 2.1 0.4 3 1.1 136 13 137 165 14.4 0 14.9 14.1 07/08/2006 12:10:00 2 0.6 3.8 0.7 2 0.6 3.8 0.4 2.3 0.5 3.8 1.1 131 9 145 165 14.7 0.3 15.2 13.8 07/08/2006 12:20:00 2.3 0.4 3 1.1 2.3 0.4 3.8 1.1 2.5 0.4 3.8 1.5 145 11 137 165 14.2 0.1 14.6 13.5 07/08/2006 12:30:00 2.3 0.4 3.4 1.5 2.3 0.4 3.8 1.5 2.5 0.4 3.4 1.5 132 8 119 165 14.3 0 14.6 13.8 07/08/2006 12:40:00 2 0.5 3.4 0.7 2 0.5 3.4 0.7 2.2 0.4 3.4 1.1 131 8 135 165 14 0.1 14.6 13.8 07/08/2006 12:50:00 1.7 0.8 3.4 0.4 1.8 0.8 3 0.4 2 0.6 3 0.4 123 13 120 165 13.9 0 14.1 13.8 07/08/2006 13:00:00 1.9 0.6 3 0.7 2 0.5 3 1.1 2.1 0.4 3 1.1 136 17 125 165 13.9 0 14.1 13.8 07/08/2006 13:10:00 1 0.5 1.9 0.4 1.3 0.4 2.3 0.4 1.6 0.4 2.6 0.4 113 20 135 165 14.2 0.1 14.6 13.8 07/08/2006 13:20:00 1.6 0.7 3 0.4 1.8 0.6 3 0.4 1.9 0.6 3 0.4 133 12 126 165 14.4 0 14.9 14.1 07/08/2006 13:30:00 1.5 0.6 3 0.4 1.7 0.6 3 0.4 1.9 0.5 2.6 0.4 123 17 116 165 14.7 0.2 15.2 14.4 07/08/2006 13:40:00 1 0.6 2.6 0.4 1.3 0.5 3 0.4 1.7 0.5 3.4 0.4 139 13 151 165 15.4 0 15.7 15.2 07/08/2006 13:50:00 0.6 0.4 1.9 0.4 0.8 0.5 2.3 0.4 1.1 0.5 2.6 0.4 143 19 125 165 15 0 15.5 14.4 07/08/2006 14:00:00 0.6 0.4 2.3 0.4 0.6 0.4 2.3 0.4 0.6 0.5 2.3 0.4 232 58 162 165 15.5 0.3 16 14.9 07/08/2006 14:10:00 0.6 0.5 2.3 0.4 0.6 0.5 2.3 0.4 0.6 0.5 2.3 0.4 201 90 175 165 16.3 0 16.6 16 07/08/2006 14:20:00 0.8 0.6 2.6 0.4 0.7 0.5 2.6 0.4 0.7 0.5 2.6 0.4 229 64 316 165 16.5 0 16.8 16.3 07/08/2006 14:30:00 1.6 0.6 3.4 0.4 1.4 0.6 3 0.4 2 0.5 3.4 0.4 199 20 177 165 16.4 0 16.8 16.3 07/08/2006 14:40:00 1.3 0.7 3.4 0.4 1.3 0.8 3.4 0.4 1 0.6 2.3 0.4 193 79 300 165 17.4 0.4 18.2 16.6 07/08/2006 14:50:00 2.5 1 5.3 0.4 2.6 1 5.3 0.4 2.3 0.9 4.6 0.4 272 47 280 165 18.5 0.2 19.1 18 07/08/2006 15:00:00 2.7 0.8 4.6 0.4 2.9 0.9 4.9 0.4 2.5 0.8 4.6 0.4 271 43 274 165 18.7 0 19.1 18.5 07/08/2006 15:10:00 1.5 0.8 4.2 0.4 1.5 0.9 4.6 0.4 1.3 0.7 3.8 0.4 222 47 235 165 18.7 0.3 19.7 18.2 07/08/2006 15:20:00 1.6 1 4.6 0.4 1.7 1.3 4.6 0.4 1.6 1 4.2 0.4 224 51 261 165 19.4 0.1 20 19.1 07/08/2006 15:30:00 1.6 0.8 3.4 0.4 1.5 0.8 3.4 0.4 1.6 0.9 3.4 0.4 174 43 164 165 19 0.4 19.7 18.2 07/08/2006 15:40:00 1.5 0.4 2.3 0.4 1.1 0.5 2.3 0.4 1.6 0.4 3 0.4 175 16 168 165 17.9 0 18.2 17.7 07/08/2006 15:50:00 1.2 1 3.8 0.4 1 1 3.4 0.4 1 0.8 3 0.4 223 69 357 165 17.6 0.1 18.2 17.4 07/08/2006 16:00:00 1.7 0.8 4.2 0.4 1.5 0.9 4.2 0.4 1.7 0.7 3 0.4 120 76 42 165 18.2 0 18.5 18 07/08/2006 16:10:00 1.3 1 4.2 0.4 1.1 0.9 4.6 0.4 0.9 0.6 3.4 0.4 21 66 25 165 18.3 0 18.5 18.2 07/08/2006 16:20:00 1.6 1.1 4.9 0.4 1.4 1.1 4.9 0.4 1.5 0.8 4.9 0.4 208 98 324 165 17.8 0.2 18.2 17.4 07/08/2006 16:30:00 4.6 1.1 7.2 1.5 4.6 1.2 7.2 1.5 3.8 1 6.1 1.5 309 15 298 165 19.1 0.5 19.7 18 07/08/2006 16:40:00 5 0.7 6.8 3 5.1 0.7 6.8 3.4 4.1 0.8 6.1 2.3 307 9 297 165 19 0.1 19.4 18.5 07/08/2006 16:50:00 5 1 8 1.9 5 1 8 2.3 4.1 1 6.5 1.5 302 9 297 165 19.4 0.1 20 18.8 07/08/2006 17:00:00 5.3 0.7 7.6 3.4 5.3 0.7 7.2 3.4 4.3 0.8 6.5 2.3 304 11 303 165 20.2 0 20.5 19.7 07/08/2006 17:10:00 5.5 0.8 8 2.6 5.6 0.8 8.4 3 4.6 0.9 7.2 2.3 301 9 303 165 20.2 0 20.5 20 07/08/2006 17:20:00 5 0.7 6.5 3 5 0.7 6.8 3 3.8 1 5.7 0.7 300 10 290 165 20.4 0 20.5 20 07/08/2006 17:30:00 5.3 0.8 6.8 3 5.3 0.8 7.2 3.4 4 1.1 7.2 1.9 301 9 306 165 20.4 0.2 20.8 20 07/08/2006 17:40:00 6.4 0.8 8.4 4.2 6.4 0.8 8.4 4.2 5.1 0.9 7.2 2.6 302 6 303 165 19.5 0.1 20 19.4 07/08/2006 17:50:00 7.3 0.8 8.8 4.9 7.3 0.8 8.8 5.3 5.8 0.8 8 3.8 304 7 307 165 18.9 0.2 19.4 18.5 07/08/2006 18:00:00 6.7 1 8.8 3.8 6.7 1 8.8 3.8 5.7 1 8.8 3 305 7 302 165 18.5 0 18.5 18.2 07/08/2006 18:10:00 6.1 0.9 8.4 3.8 6.1 0.9 8.4 4.2 5.2 1 7.6 3 303 9 292 165 18.5 0 18.8 18 07/08/2006 18:20:00 6.2 1 9.5 3.4 6.3 1 9.5 3.4 5.4 1.1 9.1 3 300 10 290 165 18.2 0.2 18.5 17.7 07/08/2006 18:30:00 6.6 1.2 8.8 3.4 6.7 1.2 9.1 3.4 5.7 1.3 8.8 2.6 291 9 294 165 18.2 0 18.5 18 07/08/2006 18:40:00 6.9 1.1 9.1 3.8 7 1.2 9.1 4.2 6.3 1.5 9.1 3.4 290 10 281 165 17.9 0 18.2 17.7 07/08/2006 18:50:00 6.8 0.7 8.8 4.6 6.7 0.6 8.8 4.6 6.4 0.8 8 4.2 312 7 296 165 18 0.1 18.2 17.7 07/08/2006 19:00:00 7.1 0.7 8.8 5.3 7 0.7 8.4 5.3 6.6 0.9 8.4 3.8 313 5 313 165 17.8 0 18 17.4 07/08/2006 19:10:00 7.6 0.7 9.5 6.1 7.5 0.7 9.1 5.7 6.8 0.9 9.1 4.2 311 6 312 165 17.4 0.1 17.7 17.1 07/08/2006 19:20:00 8 0.8 9.5 5.3 8 0.8 9.9 5.7 7.2 0.7 9.5 4.9 311 7 309 165 17.3 0 17.4 17.1 07/08/2006 19:30:00 8.3 0.7 9.9 6.5 8.3 0.7 10.3 6.5 6.7 0.8 8.4 4.6 303 5 300 165 16.9 0 17.1 16.6 07/08/2006 19:40:00 9 1 10.7 5.7 9 1 11.1 5.7 7.2 0.9 9.1 4.6 304 6 298 165 16.6 0 16.8 16.3 07/08/2006 19:50:00 9 0.7 10.3 7.2 9 0.7 10.7 7.2 7.2 0.8 9.5 5.3 304 5 308 165 16.2 0 16.6 16 07/08/2006 20:00:00 8.9 0.8 10.3 6.8 8.9 0.8 10.7 6.8 7.2 0.9 10.3 4.9 305 5 301 165 15.9 0 16.3 15.5 07/08/2006 20:10:00 9.2 0.7 10.7 6.8 9.2 0.7 11.1 6.8 6.8 0.7 9.1 4.9 300 4 301 165 15.7 0 16 15.5 07/08/2006 20:20:00 9.1 0.7 10.7 6.5 9.1 0.7 11.1 6.5 6.7 0.7 9.1 4.9 299 5 295 165 15.4 0 15.7 14.9 07/08/2006 20:30:00 9.2 0.7 10.7 6.8 9.3 0.8 11.1 6.8 6.9 0.8 9.1 4.9 300 5 293 165 15.2 0 15.5 14.9 07/08/2006 20:40:00 8.9 1.1 11.1 4.6 8.9 1.1 11.5 4.9 6.9 1 9.5 4.6 302 6 304 165 15.1 0 15.5 14.9 07/08/2006 20:50:00 9.2 1.2 11.8 6.1 9.2 1.2 11.8 5.7 7.2 1 9.9 4.6 303 5 302 165 14.8 0.1 15.2 14.6 07/08/2006 21:00:00 9.4 1 11.8 6.1 9.5 1 12.2 6.1 7.4 0.9 10.3 4.9 304 5 299 165 14.5 0 14.9 14.1 07/08/2006 21:10:00 9.5 1 11.8 6.1 9.5 1 11.5 6.5 7.2 0.9 9.5 4.9 302 6 297 165 14.1 0.2 14.6 13.5 07/08/2006 21:20:00 9.5 0.8 11.5 6.8 9.6 0.8 11.5 6.8 7 0.7 9.1 5.3 302 5 300 165 13.8 0.1 14.4 13.3 07/08/2006 21:30:00 9.4 0.6 10.7 7.2 9.5 0.6 11.1 7.2 7.1 0.8 9.5 5.3 300 5 301 165 13.7 0 14.1 13 07/08/2006 21:40:00 9 0.8 11.1 6.5 9.1 0.8 11.1 6.5 6.7 0.8 9.1 4.9 301 5 304 165 13.5 0 13.8 13 07/08/2006 21:50:00 10.3 0.8 11.8 7.2 10.4 0.8 12.2 7.2 7.4 0.8 9.9 5.7 299 3 298 165 13.5 0.1 14.1 13 07/08/2006 22:00:00 9.7 0.9 12.2 7.6 9.7 0.9 11.8 7.6 7.1 0.9 10.3 5.3 299 5 296 165 13.5 0.1 13.5 13 07/08/2006 22:10:00 9 0.7 10.7 6.5 9.1 0.8 11.1 6.5 6.9 0.8 9.1 4.9 302 6 294 165 13.5 0.1 13.5 13 07/08/2006 22:20:00 8.6 0.8 10.3 6.1 8.7 0.8 10.7 6.5 6.3 0.8 8.8 4.6 300 4 297 165 13.4 0 13.5 13.3 07/08/2006 22:30:00 8.5 0.7 9.9 6.1 8.6 0.8 9.9 6.1 6.5 1 9.5 4.2 297 4 293 165 13.5 0 13.5 13.3 07/08/2006 22:40:00 8.6 0.6 10.3 6.5 8.6 0.6 10.3 6.5 6.1 0.6 8.4 4.6 299 4 301 165 13.6 0 13.8 13.3 07/08/2006 22:50:00 8 0.6 9.5 6.1 8 0.6 9.5 6.1 5.9 0.8 8 4.6 298 5 292 165 13.7 0 13.8 13.5 07/08/2006 23:00:00 7.5 0.8 9.1 4.6 7.5 0.7 9.1 4.9 5.8 0.9 8.4 3.8 296 5 297 165 13.9 0 14.1 13.8 07/08/2006 23:10:00 7.6 0.6 8.8 4.9 7.7 0.6 9.1 4.9 5.9 0.8 8.4 4.2 295 4 292 165 13.7 0 14.1 13.5 07/08/2006 23:20:00 7.5 0.6 9.1 4.9 7.6 0.6 9.1 5.3 5.7 0.8 8 3.4 296 4 295 165 13.7 0 13.8 13.5 07/08/2006 23:30:00 7.5 0.6 9.1 6.1 7.6 0.6 8.8 6.1 5.5 0.6 8 4.2 300 4 296 165 13.7 0 13.8 13.5 07/08/2006 23:40:00 7.4 0.6 8.8 5.7 7.4 0.6 9.1 5.7 5.5 0.6 7.2 4.2 300 5 301 165 13.9 0 14.1 13.5 07/08/2006 23:50:00 7.8 0.6 9.5 6.1 7.9 0.6 9.5 6.1 5.9 0.7 8 3.8 299 5 305 165 14 0 14.4 13.8 07/09/2006 00:00:00 7.5 0.6 8.8 6.1 7.5 0.6 8.8 6.1 5.7 0.7 8 4.2 299 4 300 165 13.9 0 14.4 13.8 07/09/2006 00:10:00 7 0.6 8.4 5.3 7 0.6 8.4 5.7 5.3 0.7 7.2 3.4 300 5 303 165 13.7 0 14.1 13.5 07/09/2006 00:20:00 6.8 0.6 8 4.9 6.8 0.6 8.4 4.9 5.4 0.8 7.2 3 295 5 301 165 13.5 0 13.5 13.3 07/09/2006 00:30:00 6.4 0.6 8 4.6 6.4 0.6 7.6 4.6 5.3 0.8 7.2 3.4 293 4 291 165 13.4 0 13.5 13.3 07/09/2006 00:40:00 6.2 0.5 7.6 4.9 6.3 0.5 7.6 4.9 4.8 0.7 6.8 3.4 298 5 297 165 13.5 0 13.5 13.3 07/09/2006 00:50:00 6.4 0.4 7.6 5.3 6.5 0.4 7.6 5.7 4.7 0.5 6.1 3.8 300 3 297 165 13.6 0 13.8 13.5 07/09/2006 01:00:00 6.1 0.6 7.6 4.6 6.2 0.6 7.6 4.6 4.7 0.6 6.5 3 299 5 302 165 13.7 0 13.8 13.5 07/09/2006 01:10:00 6.8 0.8 8.8 4.6 6.9 0.8 8.4 4.6 5.4 1 8 3 296 4 298 165 13.4 0 13.8 13 07/09/2006 01:20:00 6.9 0.7 8.4 4.9 7 0.7 8.4 4.9 5.7 0.8 7.6 3.8 294 4 299 165 13.2 0 13.5 12.7 07/09/2006 01:30:00 6.5 0.5 8 5.3 6.6 0.5 8 5.3 5.3 0.8 6.8 3.4 294 5 298 165 13.1 0 13.3 12.7 07/09/2006 01:40:00 6.8 0.6 8 4.9 6.8 0.6 8 4.9 5.3 0.8 7.2 3 295 3 293 165 13 0.1 13.3 12.5 07/09/2006 01:50:00 7 0.6 8.8 5.3 7.1 0.6 9.1 5.3 5.5 0.8 7.6 3.4 294 4 285 165 13.1 0 13.3 12.7 07/09/2006 02:00:00 6.9 0.6 8.4 5.3 6.9 0.6 8.4 5.3 5.3 0.8 7.6 3.8 295 4 292 165 13 0.1 13.3 12.5 07/09/2006 02:10:00 7.1 0.5 8 5.7 7.2 0.5 8.4 6.1 5.4 0.7 7.2 3.4 296 3 297 165 13.1 0 13.5 12.7 07/09/2006 02:20:00 7 0.7 9.1 4.9 7.1 0.7 9.5 4.9 5.5 0.8 7.2 3.8 298 6 308 165 13.2 0 13.5 12.7 07/09/2006 02:30:00 7.2 0.5 8.8 5.7 7.2 0.5 8.8 5.7 5.3 0.7 8 3.8 299 4 291 165 13.1 0 13.3 12.7 07/09/2006 02:40:00 7.2 0.5 8.8 6.1 7.3 0.5 8.8 6.1 5.2 0.5 6.8 3.8 300 3 300 165 12.9 0.1 13.3 12.5 07/09/2006 02:50:00 7.4 0.5 8.8 5.7 7.4 0.5 8.8 5.7 5.3 0.6 7.6 3.8 300 4 296 165 13 0.1 13.3 12.5 07/09/2006 03:00:00 7.6 0.5 8.8 6.1 7.6 0.4 8.8 6.5 5.5 0.6 7.2 4.2 299 3 309 165 13 0 13.3 12.5 07/09/2006 03:10:00 7.3 0.5 8.8 5.7 7.4 0.5 8.4 5.7 5.5 0.7 7.2 4.2 298 4 297 165 13 0 13.3 12.5 07/09/2006 03:20:00 7.4 0.6 9.1 6.1 7.5 0.6 9.1 6.1 6 0.8 8.4 4.2 295 5 301 165 12.9 0 13 12.5 07/09/2006 03:30:00 7.5 0.5 8.8 6.1 7.5 0.5 8.8 6.1 5.7 0.7 8 3.4 296 4 303 165 12.9 0 13 12.7 07/09/2006 03:40:00 7.3 0.8 9.1 4.6 7.4 0.8 9.1 4.6 6.1 1.1 8.8 3.8 293 5 290 165 12.9 0 13 12.5 07/09/2006 03:50:00 7.3 0.5 8.8 5.7 7.3 0.5 8.8 6.1 5.4 0.7 8 3.4 297 4 299 165 12.7 0 13 12.5 07/09/2006 04:00:00 7.3 0.6 8.8 5.7 7.4 0.5 8.8 5.7 5.6 0.8 7.6 3.8 297 4 295 165 12.7 0 13 12.5 07/09/2006 04:10:00 7.5 0.6 8.8 5.7 7.5 0.6 8.8 5.3 5.5 0.5 7.6 4.2 300 3 300 165 12.7 0 13 12.5 07/09/2006 04:20:00 6.2 1 8.4 3.8 6.2 1 8.4 3.8 4.9 0.8 6.8 3 302 7 302 165 12.5 0 13 12.2 07/09/2006 04:30:00 5.7 0.6 7.6 4.2 5.7 0.6 7.6 4.2 4.8 0.7 6.8 3.4 305 6 302 165 12.3 0 12.7 11.9 07/09/2006 04:40:00 5.2 0.7 6.8 3 5.3 0.7 6.8 3 4.1 0.6 6.1 2.6 301 6 306 165 12.3 0 12.7 11.9 07/09/2006 04:50:00 4.6 0.8 6.1 2.3 4.7 0.8 6.5 2.3 3.6 0.6 5.7 2.3 297 7 306 165 12.3 0.1 12.5 11.9 07/09/2006 05:00:00 4 0.7 5.7 1.9 4 0.7 5.7 1.9 3.5 0.6 4.9 1.9 296 7 295 165 12.3 0.1 12.5 11.9 07/09/2006 05:10:00 4.5 0.9 6.5 2.6 4.6 0.8 6.5 3 3.7 0.7 6.1 2.3 296 6 301 165 12.3 0.1 12.5 11.9 07/09/2006 05:20:00 4.6 0.7 6.5 3 4.7 0.7 6.1 3 3.8 0.7 6.1 2.3 296 7 302 165 12.4 0.1 12.7 11.9 07/09/2006 05:30:00 4.6 0.6 6.1 3 4.6 0.6 6.1 3.4 3.8 0.7 6.1 2.3 295 7 294 165 12.6 0 12.7 12.5 07/09/2006 05:40:00 5.5 0.6 7.6 3.8 5.5 0.6 7.6 4.2 4.2 0.7 6.1 3 298 6 294 165 12.5 0 12.7 12.2 07/09/2006 05:50:00 5.3 0.6 6.5 3.8 5.4 0.6 6.8 3.8 4.4 0.7 6.8 3 302 8 304 165 12.9 0.1 13.3 12.5 07/09/2006 06:00:00 4.7 0.6 6.5 3 4.7 0.6 6.5 3 4 0.8 6.1 2.3 300 8 309 165 12.9 0.2 13.3 12.5 07/09/2006 06:10:00 6 1 8.4 3.4 6 1 8 3.8 4.7 0.8 6.5 3 300 6 297 165 12.9 0.1 13.3 12.5 07/09/2006 06:20:00 5.7 0.5 7.2 4.2 5.7 0.5 7.2 3.8 4.5 0.7 7.6 3 296 5 297 165 13.1 0 13.3 12.7 07/09/2006 06:30:00 5.5 0.5 7.2 4.2 5.6 0.6 6.8 4.2 4.6 0.8 6.8 3 298 5 302 165 12.9 0.1 13 12.5 07/09/2006 06:40:00 5.3 0.5 6.5 3.8 5.3 0.5 6.5 3.8 4.2 0.8 6.8 2.6 297 5 304 165 13.1 0 13.3 12.7 07/09/2006 06:50:00 5.4 0.6 6.5 3.8 5.5 0.6 6.5 3.8 4.4 0.7 6.1 2.6 296 5 298 165 13.4 0 13.5 13 07/09/2006 07:00:00 4.6 0.5 5.7 3.4 4.7 0.5 5.7 3.4 3.7 0.6 5.3 2.6 297 6 298 165 13.7 0 13.8 13.3 07/09/2006 07:10:00 3.8 0.5 4.9 2.6 3.9 0.5 5.3 2.6 3.1 0.5 5.3 1.9 296 6 293 165 13.9 0.1 14.1 13.5 07/09/2006 07:20:00 3.3 0.4 4.2 2.3 3.4 0.3 4.2 2.3 2.9 0.5 4.2 1.5 298 5 296 165 14.1 0 14.4 13.5 07/09/2006 07:30:00 2.5 0.6 4.2 1.1 2.7 0.6 4.2 1.1 2.3 0.6 3.8 1.1 288 8 299 165 15 0.3 15.7 13.8 07/09/2006 07:40:00 0.8 0.6 2.6 0.4 0.9 0.6 2.6 0.4 1.1 0.6 3 0.4 269 33 283 165 15.6 0 15.7 15.2 07/09/2006 07:50:00 0.8 0.5 2.3 0.4 0.6 0.4 2.6 0.4 0.9 0.6 2.3 0.4 158 39 165 165 15.2 0.2 15.7 14.6 07/09/2006 08:00:00 1.1 0.6 2.6 0.4 0.9 0.5 2.3 0.4 1.5 0.5 2.6 0.4 149 18 164 165 14.8 0 15.2 14.4 07/09/2006 08:10:00 1.2 0.5 2.6 0.4 0.9 0.5 2.3 0.4 1.2 0.5 2.3 0.4 175 32 194 165 14.8 0.1 15.2 14.4 07/09/2006 08:20:00 0.9 0.5 2.3 0.4 0.6 0.4 1.9 0.4 0.8 0.5 2.3 0.4 176 27 194 165 15 0 15.2 14.9 07/09/2006 08:30:00 0.9 0.6 2.3 0.4 0.7 0.5 2.3 0.4 1.3 0.7 3 0.4 149 43 166 165 15.3 0.1 15.7 14.9 07/09/2006 08:40:00 1.4 0.7 3 0.4 1.1 0.7 2.6 0.4 1.6 0.6 3 0.4 138 24 137 165 15.5 0.2 16 15.2 07/09/2006 08:50:00 1.6 0.6 3 0.4 1.3 0.6 3 0.4 1.7 0.8 3.8 0.4 150 33 101 165 15.1 0 15.5 14.9 07/09/2006 09:00:00 1.4 0.6 2.6 0.4 1.1 0.6 2.6 0.4 1.5 0.5 3 0.4 160 28 217 165 15.5 0 16 15.2 07/09/2006 09:10:00 1.6 0.8 3.4 0.4 1.3 0.9 3.4 0.4 1.7 0.9 3.8 0.4 150 16 148 165 15.9 0 16.3 15.5 07/09/2006 09:20:00 0.9 0.6 2.6 0.4 0.7 0.6 2.6 0.4 1.3 0.6 3 0.4 130 13 114 165 14.5 0.6 15.7 13.5 07/09/2006 09:30:00 1.2 0.8 3 0.4 1 0.8 3 0.4 1.4 0.7 3.4 0.4 141 23 136 165 13.3 0 13.5 13 07/09/2006 09:40:00 3.2 0.4 4.2 1.9 3.1 0.4 4.2 1.9 3.1 0.3 3.8 2.3 124 5 126 165 12.5 0.1 13 12.2 07/09/2006 09:50:00 2.5 0.4 3.4 1.1 2.5 0.4 3.4 1.1 2.6 0.4 3.4 1.5 140 10 138 165 12.9 0.1 13 12.7 07/09/2006 10:00:00 2.6 0.4 3.4 1.9 2.5 0.5 3.4 1.5 2.6 0.5 3.4 1.5 145 5 150 165 13.1 0 13.3 12.7 07/09/2006 10:10:00 2.9 0.4 3.8 2.3 2.9 0.4 3.8 2.3 3 0.3 3.8 2.3 146 6 151 165 13.3 0.1 13.5 13 07/09/2006 10:20:00 2.4 0.4 3.4 1.1 2.4 0.5 3.4 1.1 2.5 0.4 3.4 1.5 140 8 138 165 13.5 0 13.5 13.3 07/09/2006 10:30:00 2.5 0.5 3.8 1.5 2.5 0.6 3.8 1.5 2.6 0.5 3.8 1.5 143 8 136 165 13.4 0 13.5 13.3 07/09/2006 10:40:00 2.5 0.5 3.8 1.1 2.5 0.5 3.8 1.5 2.7 0.5 3.8 1.5 132 10 126 165 13.5 0 13.8 13.3 07/09/2006 10:50:00 3 0.4 3.8 1.9 2.9 0.4 3.8 1.9 3.1 0.5 4.2 1.9 128 8 125 165 13.5 0 13.8 13.3 07/09/2006 11:00:00 2.9 0.5 4.2 1.1 2.9 0.5 4.2 1.5 3 0.5 4.2 1.9 131 13 115 165 13.9 0.1 14.1 13.5 07/09/2006 11:10:00 2 0.4 3.4 0.7 2.1 0.4 3 1.1 2.3 0.4 3 1.1 129 11 148 165 14.2 0 14.6 13.8 07/09/2006 11:20:00 1.3 0.7 3 0.4 1.2 0.7 3 0.4 1.4 0.7 3.4 0.4 130 32 141 165 14.6 0.2 15.2 14.4 07/09/2006 11:30:00 1.6 0.6 3 0.4 1.6 0.7 3.4 0.4 1.9 0.7 3.8 0.4 143 13 150 165 15 0 15.2 14.6 07/09/2006 11:40:00 1.5 0.6 2.6 0.4 1.5 0.6 2.6 0.4 1.7 0.4 3 0.7 108 17 111 165 14.8 0 15.2 14.6 07/09/2006 11:50:00 1.8 0.6 3 0.4 1.9 0.6 3 0.4 2 0.6 3.4 0.4 100 18 121 165 15.5 0.3 16 14.9 07/09/2006 12:00:00 1.9 0.5 3 0.7 1.9 0.5 3 0.4 1.8 0.6 3 0.4 111 17 94 165 15.5 0.1 16.3 15.2 07/09/2006 12:10:00 1.8 0.7 3 0.4 1.8 0.7 3 0.4 1.8 0.6 3.4 0.4 116 21 87 165 15.2 0.1 15.7 15.2 07/09/2006 12:20:00 2 0.6 3.4 0.4 2.1 0.6 3.4 0.4 1.8 0.7 3.8 0.4 108 15 102 165 15.3 0 15.7 15.2 07/09/2006 12:30:00 2.1 0.7 3.4 0.4 2.2 0.7 3.4 0.4 2.3 0.5 3.4 0.7 115 17 121 165 15.6 0 15.7 15.2 07/09/2006 12:40:00 2.5 0.7 3.8 0.4 2.5 0.8 3.8 0.4 2.4 0.7 3.8 0.4 119 22 105 165 15.4 0.2 15.7 14.9 07/09/2006 12:50:00 2.9 0.4 3.8 1.1 2.9 0.4 3.8 1.1 2.8 0.5 3.8 1.1 123 11 108 165 15.2 0.1 15.5 15.2 07/09/2006 13:00:00 3 0.5 5.3 1.9 3 0.5 4.9 1.5 2.8 0.5 4.2 0.7 118 9 111 165 15.1 0 15.5 14.9 07/09/2006 13:10:00 2.6 0.4 3.4 1.5 2.6 0.4 3.4 1.5 2.5 0.4 3.4 1.1 118 6 117 165 15.3 0 15.7 15.2 07/09/2006 13:20:00 2.9 0.3 3.8 2.3 2.9 0.3 3.8 2.3 2.9 0.4 3.8 1.5 116 5 106 165 15.2 0 15.5 15.2 07/09/2006 13:30:00 2.8 0.5 3.8 0.7 2.9 0.5 4.2 0.4 2.9 0.5 4.2 1.1 114 8 123 165 15.2 0 15.5 15.2 07/09/2006 13:40:00 3.1 0.4 4.2 1.9 3.1 0.4 4.2 1.9 3.1 0.4 4.2 1.9 116 6 112 165 15.2 0 15.5 15.2 07/09/2006 13:50:00 2.9 0.3 3.4 1.5 2.9 0.3 3.8 1.5 2.9 0.3 3.8 1.9 117 6 115 165 15.2 0 15.5 15.2 07/09/2006 14:00:00 2 0.6 3.4 0.4 2.1 0.6 3.4 0.4 2.1 0.5 3.4 0.7 110 10 117 165 15.5 0 15.7 15.2 07/09/2006 14:10:00 1.1 0.5 2.6 0.4 1.3 0.5 3 0.4 1.6 0.6 3 0.4 112 20 135 165 16 0.2 16.3 15.7 07/09/2006 14:20:00 1.6 0.4 2.6 0.7 1.7 0.5 2.6 0.4 2 0.5 3.4 0.7 118 11 116 165 16.3 0.1 16.8 16 07/09/2006 14:30:00 1.7 0.7 3.8 0.4 1.8 0.7 3.4 0.4 2.3 0.5 3.4 1.1 123 16 139 165 15.9 0 16.3 15.7 07/09/2006 14:40:00 1.7 0.6 3 0.4 1.8 0.6 3 0.4 2.1 0.6 3.4 0.4 117 13 143 165 15.7 0 16 15.5 07/09/2006 14:50:00 2.4 0.5 3.4 0.4 2.5 0.6 3.8 0.7 2.5 0.6 4.2 1.1 100 12 105 165 15.5 0 15.7 15.2 07/09/2006 15:00:00 2.2 0.5 3.8 1.1 2.4 0.4 3.4 1.5 2.5 0.4 3.4 1.5 107 11 101 165 15.5 0 15.7 15.2 07/09/2006 15:10:00 2.8 0.6 4.6 1.1 3.1 0.6 4.6 1.5 3.2 0.5 4.6 1.5 118 9 110 165 15.9 0 16.3 15.2 07/09/2006 15:20:00 2.9 0.6 4.6 1.5 3.1 0.5 4.6 1.5 3.1 0.5 4.6 1.9 121 10 129 165 16.1 0.3 16.8 15.7 07/09/2006 15:30:00 2.3 0.9 4.2 0.4 2.4 0.9 4.6 0.4 2.5 0.9 4.2 0.4 126 20 145 165 16.5 0 16.8 16.3 07/09/2006 15:40:00 1.5 0.5 3.4 0.4 1.7 0.6 3.4 0.4 1.9 0.5 3 0.4 104 20 122 165 17.2 0.3 17.7 16.6 07/09/2006 15:50:00 2.5 0.5 3.8 1.5 2.5 0.5 3.8 1.5 2.7 0.6 4.2 1.1 118 8 116 165 17.5 0.2 18 17.1 07/09/2006 16:00:00 3.5 0.5 4.9 2.3 3.6 0.5 4.9 2.3 3.6 0.5 4.9 1.9 120 10 130 165 17.1 0.2 17.7 16.8 07/09/2006 16:10:00 3.8 0.6 5.3 2.3 3.9 0.6 5.7 2.3 3.9 0.7 5.7 2.3 119 7 130 165 16.6 0 16.8 16.3 07/09/2006 16:20:00 4.4 0.4 5.7 3.4 4.5 0.4 6.1 3.4 4.6 0.4 5.7 3.4 121 5 123 165 16.1 0.2 16.6 15.7 07/09/2006 16:30:00 3.9 0.5 5.3 2.6 4 0.5 5.3 2.6 4 0.5 5.7 2.6 135 9 143 165 16.3 0.2 16.8 15.7 07/09/2006 16:40:00 2.9 0.4 4.2 1.9 2.9 0.4 4.2 1.9 2.9 0.4 3.8 2.3 135 9 143 165 16.2 0.1 16.6 16 07/09/2006 16:50:00 2.5 0.5 3.8 1.1 2.5 0.6 4.2 0.7 2.5 0.6 3.8 0.7 130 11 122 165 16.1 0.1 16.3 15.7 07/09/2006 17:00:00 2.6 0.5 4.2 1.5 2.7 0.5 4.2 1.5 2.6 0.6 4.2 0.7 127 13 121 165 15.9 0.3 16.6 15.5 07/09/2006 17:10:00 2.5 0.7 3.8 0.7 2.6 0.6 3.8 0.7 2.5 0.6 3.8 1.1 138 16 157 165 15.5 0 16 15.2 07/09/2006 17:20:00 3 0.5 4.6 1.9 3 0.5 4.6 1.9 3 0.5 4.2 1.5 125 6 130 165 15.3 0.2 15.7 14.9 07/09/2006 17:30:00 3.1 0.5 4.2 1.9 3.2 0.5 4.2 1.9 3.1 0.5 4.2 1.9 131 7 118 165 14.8 0.1 15.2 14.6 07/09/2006 17:40:00 2.4 0.4 3.4 1.1 2.4 0.4 3.4 1.1 2.4 0.4 3.4 1.5 111 8 117 165 14.4 0 14.6 14.1 07/09/2006 17:50:00 3.2 0.4 4.2 2.3 3.2 0.4 4.2 2.3 3.1 0.4 3.8 1.9 110 9 119 165 13.7 0.2 14.4 13 07/09/2006 18:00:00 3.1 0.4 4.2 1.9 3.2 0.4 4.2 2.3 2.8 0.4 3.8 1.5 103 7 102 165 13.5 0 13.5 13 07/09/2006 18:10:00 3.5 0.4 4.2 2.3 3.6 0.4 4.6 2.6 3.3 0.4 4.2 2.3 103 7 98 165 13.3 0 13.5 12.7 07/09/2006 18:20:00 3.6 0.4 4.6 2.6 3.7 0.4 4.6 2.6 3.4 0.4 4.2 2.3 120 12 99 165 13.7 0 13.8 13.3 07/09/2006 18:30:00 4.7 0.5 6.1 3.8 4.7 0.5 6.1 3.4 4.6 0.5 6.1 3 129 6 132 165 12.7 0.3 13.5 12.2 07/09/2006 18:40:00 6.1 0.6 7.6 4.2 6.2 0.6 7.2 4.2 5.9 0.6 7.6 4.2 127 7 126 165 12.1 0.2 12.5 11.9 07/09/2006 18:50:00 6 0.4 7.2 4.9 6.1 0.4 7.2 4.9 6 0.5 8 4.6 121 5 124 165 11.3 0.2 11.9 11.1 07/09/2006 19:00:00 5.8 0.5 6.8 4.6 5.8 0.5 6.8 4.6 5.6 0.5 6.8 4.2 126 7 119 165 11.1 0 11.4 10.9 07/09/2006 19:10:00 5.8 0.4 6.8 4.6 5.9 0.4 6.8 4.6 5.7 0.5 6.8 4.6 127 5 121 165 11.1 0.1 11.7 10.9 07/09/2006 19:20:00 5.3 0.4 6.5 4.2 5.4 0.4 6.5 4.6 5.3 0.4 6.5 4.2 131 6 137 165 10.8 0.1 11.4 10.3 07/09/2006 19:30:00 6 0.4 6.8 4.9 6.1 0.4 7.2 4.9 6 0.5 6.8 4.2 136 6 129 165 10.4 0.2 10.9 10.3 07/09/2006 19:40:00 6.1 0.4 7.6 5.3 6.2 0.4 7.2 5.3 6 0.4 7.2 4.6 134 4 136 165 10.1 0 10.6 9.8 07/09/2006 19:50:00 6.9 0.6 8.4 5.7 6.9 0.5 8.4 5.7 6.8 0.6 8.4 5.3 138 4 137 165 9.8 0 10.3 9.6 07/09/2006 20:00:00 7.8 0.4 8.8 6.8 7.8 0.4 8.8 6.8 7.8 0.5 8.8 6.1 143 4 145 165 9.8 0 10.1 9.6 07/09/2006 20:10:00 8.3 0.3 9.1 7.6 8.3 0.2 9.1 7.6 8.4 0.3 9.1 7.2 146 3 148 165 9.9 0 10.1 9.6 07/09/2006 20:20:00 8.7 0.4 9.9 7.6 8.6 0.4 9.5 7.6 8.8 0.5 9.9 7.6 150 3 151 165 9.6 0.1 10.1 9.3 07/09/2006 20:30:00 8.9 0.4 9.9 7.6 8.8 0.3 9.5 7.6 9.1 0.4 10.3 7.6 152 2 154 165 9.5 0.1 9.6 9 07/09/2006 20:40:00 9 0.4 9.9 8 8.9 0.4 9.9 8 9.1 0.4 10.3 8 150 2 151 165 9.3 0 9.8 8.8 07/09/2006 20:50:00 9.9 0.4 10.7 8.8 9.8 0.4 10.7 8.8 10 0.4 11.1 8.8 150 2 150 165 9.1 0 9.3 8.8 07/09/2006 21:00:00 10 0.4 11.1 8.8 9.9 0.4 11.1 8.8 10.2 0.4 11.1 8.4 151 3 150 165 8.9 0 9 8.8 07/09/2006 21:10:00 9.4 0.5 10.7 8.4 9.3 0.5 10.7 8 9.5 0.5 10.7 8 152 3 156 165 8.7 0 9 8.5 07/09/2006 21:20:00 9.2 0.5 10.7 7.2 9.1 0.5 10.3 7.2 9.3 0.5 10.7 7.6 153 3 148 165 8.7 0 9 8.5 07/09/2006 21:30:00 8.7 0.4 9.5 7.6 8.6 0.4 9.5 7.2 8.8 0.5 9.9 6.8 157 3 147 165 8.7 0 9 8.5 07/09/2006 21:40:00 9.1 0.5 10.3 8 8.9 0.4 9.9 7.6 9.3 0.4 10.3 8 157 3 162 165 8.7 0 9 8.3 07/09/2006 21:50:00 8.7 0.5 9.5 7.6 8.6 0.4 9.9 7.2 9 0.5 10.3 7.6 155 4 156 165 8.6 0.1 8.8 8.3 07/09/2006 22:00:00 8.5 0.4 9.1 7.2 8.4 0.4 9.5 7.2 8.7 0.4 9.9 7.2 156 3 151 165 8.5 0.1 8.8 8.3 07/09/2006 22:10:00 8.5 0.5 10.3 7.2 8.4 0.5 9.9 6.8 8.8 0.5 9.9 6.5 157 3 164 165 8.5 0.1 9 8.3 07/09/2006 22:20:00 8.6 0.6 9.9 6.8 8.4 0.6 10.3 6.8 8.8 0.6 10.3 7.2 158 11 155 165 8.5 0.1 8.8 8.3 07/09/2006 22:30:00 9.5 0.6 10.7 7.6 9.4 0.6 10.7 7.2 9.8 0.6 11.1 7.6 155 4 162 165 8.6 0 9 8.3 07/09/2006 22:40:00 9.8 0.5 11.5 8.4 9.7 0.5 11.1 8.4 10.1 0.5 11.1 8 155 2 160 165 8.7 0 9 8.5 07/09/2006 22:50:00 9.1 0.6 10.3 7.2 9 0.6 10.3 7.2 9.4 0.6 10.7 6.8 156 3 153 165 8.6 0 8.8 8.5 07/09/2006 23:00:00 8.1 0.8 10.3 6.1 8.1 0.7 9.9 6.1 8 1 9.9 5.7 162 4 154 165 8.6 0 8.8 8.5 07/09/2006 23:10:00 8.7 0.6 10.3 6.8 8.6 0.6 9.9 6.5 8.8 0.7 10.7 6.5 155 5 165 165 8.6 0 8.8 8.5 07/09/2006 23:20:00 8 0.5 9.5 6.8 7.9 0.5 9.1 6.8 8.2 0.6 9.5 6.8 155 3 160 165 8.5 0 8.8 8.5 07/09/2006 23:30:00 7.9 0.4 8.8 6.5 8 0.4 9.1 6.5 7.9 0.5 9.1 6.5 148 5 139 165 8.5 0 8.8 8.5 07/09/2006 23:40:00 7.8 0.3 8.8 6.8 7.8 0.3 8.8 6.8 7.9 0.4 9.1 6.8 153 3 153 165 8.5 0 9 8.5 07/09/2006 23:50:00 8.9 1.1 11.1 6.5 9 1 11.1 6.8 9.1 1.1 11.1 6.5 145 6 151 165 8.5 0 8.8 8.3 07/10/2006 00:00:00 9.9 0.5 11.1 8.8 9.9 0.5 11.1 8.8 9.9 0.6 11.1 7.6 152 4 156 165 8.4 0.1 8.8 8 07/10/2006 00:10:00 9.2 0.8 11.5 7.2 9.1 0.8 11.1 7.2 9.1 1 11.1 6.5 153 3 151 165 8.2 0 8.5 8 07/10/2006 00:20:00 8 0.5 9.1 6.5 8 0.4 9.1 6.5 8.1 0.6 9.5 6.1 152 5 152 165 8.3 0.1 8.5 8 07/10/2006 00:30:00 8.1 0.4 9.1 6.8 8.1 0.4 9.1 6.8 8.1 0.5 9.9 6.5 153 3 154 165 8.5 0.1 8.5 8 07/10/2006 00:40:00 9.1 0.9 10.7 6.5 9.1 0.9 11.1 6.5 9 0.9 11.1 6.5 149 5 149 165 8.5 0.1 8.5 8 07/10/2006 00:50:00 8.9 0.6 10.3 7.6 9 0.6 10.3 7.6 9 0.6 10.7 7.6 146 5 151 165 8.3 0 8.8 7.8 07/10/2006 01:00:00 8.5 0.6 10.7 6.8 8.5 0.6 10.7 6.8 8.4 0.6 11.1 7.2 142 5 136 165 8.1 0 8.5 7.5 07/10/2006 01:10:00 8 0.8 9.9 6.1 8 0.8 9.9 6.1 8.1 0.8 9.9 6.5 146 6 135 165 8.1 0 8.3 7.8 07/10/2006 01:20:00 8 0.6 9.9 6.1 7.9 0.6 9.5 6.5 7.9 0.6 9.9 6.5 146 6 154 165 8.2 0 8.5 7.8 07/10/2006 01:30:00 9.1 0.7 10.7 6.8 9.1 0.6 10.7 7.2 9.1 0.7 10.7 7.2 151 5 153 165 8.3 0 8.5 7.8 07/10/2006 01:40:00 8.9 0.8 11.1 6.8 8.9 0.8 11.1 6.5 8.8 0.8 11.1 6.8 148 8 140 165 8.4 0 8.5 8 07/10/2006 01:50:00 9.9 0.5 10.7 8 9.9 0.5 11.1 8 9.9 0.6 11.5 8 145 3 140 165 8.4 0 8.5 8 07/10/2006 02:00:00 9.2 0.7 10.7 7.6 9.2 0.7 10.7 7.6 9.1 0.7 11.1 7.2 145 5 142 165 8.4 0 8.8 8 07/10/2006 02:10:00 7.8 0.5 9.5 6.8 7.8 0.5 9.5 6.8 7.9 0.4 9.5 6.5 148 5 145 165 8.4 0.1 8.5 7.8 07/10/2006 02:20:00 7 0.5 8.4 5.3 7 0.5 8 4.9 7.1 0.6 8.4 4.9 147 6 154 165 8.3 0 8.5 7.8 07/10/2006 02:30:00 7.4 0.6 8.8 6.1 7.4 0.6 8.8 5.7 7.3 0.6 8.8 5.3 138 6 140 165 8.3 0 8.5 7.8 07/10/2006 02:40:00 7 0.7 8.8 4.9 7 0.7 8.8 4.9 6.9 0.7 8.4 4.9 138 6 134 165 8.2 0 8.5 7.8 07/10/2006 02:50:00 7.6 0.8 9.5 5.3 7.6 0.8 9.9 5.3 7.5 0.9 9.5 4.9 134 10 136 165 8.1 0 8.3 7.8 07/10/2006 03:00:00 8.8 0.9 10.7 6.5 8.8 0.9 11.1 6.5 8.6 1 11.1 6.1 140 6 137 165 8.1 0 8.3 7.5 07/10/2006 03:10:00 8.5 0.8 10.7 6.5 8.4 0.8 10.7 6.5 8.5 0.8 10.3 6.1 142 5 141 165 7.9 0.2 8.3 7.5 07/10/2006 03:20:00 9.1 0.7 11.1 6.8 9.1 0.8 11.1 7.2 9 0.8 11.1 6.1 142 5 139 165 7.9 0.2 8 7.5 07/10/2006 03:30:00 7.4 0.6 9.1 5.3 7.4 0.6 9.1 5.7 7.3 0.6 8.8 5.3 139 6 141 165 7.9 0.1 8.3 7.5 07/10/2006 03:40:00 8.3 0.4 9.5 7.2 8.2 0.4 9.9 7.2 8.2 0.5 9.1 6.8 147 3 140 165 8 0.1 8.3 7.5 07/10/2006 03:50:00 8.5 0.8 9.9 6.8 8.5 0.7 9.9 6.8 8.4 0.9 10.7 6.1 146 6 143 165 8.1 0 8.5 7.5 07/10/2006 04:00:00 9.4 0.8 11.5 6.5 9.4 0.8 11.5 6.8 9.4 0.8 11.8 7.2 142 5 142 165 8.1 0.2 8.3 7.5 07/10/2006 04:10:00 9.5 0.7 11.1 7.6 9.4 0.7 11.1 7.2 9.4 0.8 11.5 7.2 139 7 144 165 8 0.2 8.3 7.5 07/10/2006 04:20:00 8 0.8 10.3 6.1 8.1 0.8 11.1 6.1 8 0.9 10.7 5.7 134 6 139 165 8.1 0.1 8.3 7.5 07/10/2006 04:30:00 8.9 0.7 11.1 6.8 8.9 0.7 11.1 6.8 8.9 0.7 10.7 6.1 140 6 143 165 8.1 0.1 8.3 7.5 07/10/2006 04:40:00 10 1.3 13.3 6.5 10 1.3 13.7 6.8 9.9 1.5 13.7 6.5 135 7 126 165 8.1 0.1 8.3 7.5 07/10/2006 04:50:00 10.6 0.9 12.6 7.6 10.6 0.9 12.6 6.8 10.6 1 13 6.8 143 5 145 165 8 0.1 8.3 7.5 07/10/2006 05:00:00 9.5 0.7 11.1 7.6 9.5 0.7 11.1 7.6 9.5 0.9 11.8 6.8 143 6 134 165 8.1 0 8.8 7.5 07/10/2006 05:10:00 10.6 0.9 12.6 8 10.6 0.9 12.6 7.6 10.5 1.1 12.6 7.2 142 5 145 165 8.1 0 8.3 7.5 07/10/2006 05:20:00 9.2 1 12.2 6.5 9.3 1 12.2 6.5 9.1 1 12.2 6.8 134 7 133 165 8.1 0 8.3 7.5 07/10/2006 05:30:00 10 0.8 12.2 8 10.1 0.9 12.2 8 9.9 0.9 12.6 7.6 131 7 138 165 7.8 0 8.3 7.5 07/10/2006 05:40:00 9.2 1.1 11.8 6.5 9.2 1.1 11.5 6.5 9.1 1.1 11.5 6.1 142 6 142 165 7.7 0 8 7.5 07/10/2006 05:50:00 8.9 0.9 11.1 6.1 9 0.9 11.1 5.7 8.8 1 10.7 5.7 138 8 144 165 7.7 0 8 7.5 07/10/2006 06:00:00 8.4 0.8 11.8 5.7 8.5 0.8 10.7 6.1 8.3 0.9 11.5 5.3 135 6 140 165 7.6 0 7.8 7.5 07/10/2006 06:10:00 9.2 1 11.8 6.5 9.4 1 11.8 6.8 9.1 1 11.8 6.5 129 7 122 165 7.7 0 7.8 7.5 07/10/2006 06:20:00 9.2 1 12.2 6.8 9.4 1 11.8 6.5 9.1 1 12.2 6.8 131 6 134 165 7.8 0 7.8 7.8 07/10/2006 06:30:00 8.6 1 11.1 5.7 8.7 0.9 11.1 5.7 8.4 1 11.1 5.7 127 6 119 165 7.8 0 8 7.8 07/10/2006 06:40:00 10.9 1.4 14.5 7.6 11.1 1.4 15.3 7.6 10.7 1.6 14.5 7.2 126 7 123 165 7.9 0 8 7.8 07/10/2006 06:50:00 9.5 1.1 13.3 7.2 9.7 1.1 13.3 7.2 9.3 1.3 13.3 6.5 130 6 133 165 7.9 0 8 7.8 07/10/2006 07:00:00 10.5 1.1 13.7 8 10.6 1.1 13.7 8 10.3 1.2 13.7 7.2 133 7 125 165 8 0 8.3 7.8 07/10/2006 07:10:00 9.9 1 11.8 7.2 10 1 12.2 7.2 9.7 1 11.8 6.8 129 7 130 165 8 0 8.5 8 07/10/2006 07:20:00 10.1 1 13.7 6.5 10.3 1.1 13.3 6.5 9.9 1 12.2 7.2 127 6 119 165 8 0 8.3 8 07/10/2006 07:30:00 10 0.8 11.8 7.6 10.1 0.8 12.2 8 9.7 0.9 11.8 6.8 132 6 137 165 8.1 0 8.5 8 07/10/2006 07:40:00 11.1 0.9 13 8.4 11.2 0.9 13 8.4 10.9 1 13 7.2 132 6 139 165 8.2 0 8.8 8 07/10/2006 07:50:00 11.3 1.3 14.5 7.2 11.4 1.3 14.5 7.6 11 1.3 13.7 7.2 130 6 129 165 8.2 0 8.3 7.8 07/10/2006 08:00:00 10.6 1 13.3 7.6 10.7 1 13.3 7.6 10.3 1.2 13 7.2 130 7 132 165 8.3 0 8.5 8.3 07/10/2006 08:10:00 11.3 1.2 14.9 8 11.5 1.2 15.3 7.6 11.2 1.2 13.7 7.6 131 7 116 165 8.3 0 8.5 8.3 07/10/2006 08:20:00 9.9 0.8 12.2 7.2 10.1 0.8 12.2 7.2 9.7 0.8 11.8 7.2 126 6 135 165 8.5 0 8.5 8.3 07/10/2006 08:30:00 10.9 0.9 13.7 8.8 11.1 0.9 14.1 8.4 10.6 1 13.3 8 124 6 126 165 8.3 0 8.8 8 07/10/2006 08:40:00 10.4 1.1 13.3 7.6 10.6 1.2 13.7 7.2 10.3 1.1 13.3 8 129 7 120 165 8.4 0 8.5 8.3 07/10/2006 08:50:00 10.4 1.2 13.3 7.6 10.6 1.2 13.7 7.6 10.3 1.3 13.3 6.5 123 6 105 165 8.5 0 8.5 7.8 07/10/2006 09:00:00 11.7 1 14.1 9.1 11.8 1 14.1 8.8 11.3 1.1 13.7 8 123 6 128 165 8.4 0 8.8 8.3 07/10/2006 09:10:00 9.6 0.9 11.8 7.2 9.7 0.9 11.8 7.6 9.5 0.9 11.8 7.2 130 7 129 165 8.5 0.1 8.8 8.3 07/10/2006 09:20:00 10.6 1 13.3 8 10.7 1 13.3 8 10.4 1 13 7.6 134 7 136 165 8.5 0 9 8.3 07/10/2006 09:30:00 10.6 1.2 13.7 8 10.7 1.2 14.1 8 10.2 1.3 13.3 5.7 131 8 131 165 8.5 0 8.8 8.3 07/10/2006 09:40:00 10.8 1.3 14.1 7.6 10.9 1.3 14.1 7.6 10.6 1.3 13.7 7.6 132 9 126 165 8.5 0 9 8.3 07/10/2006 09:50:00 12.6 1.6 16.4 8.8 12.6 1.6 16.4 8.8 12.3 1.7 16.4 8.8 138 6 139 165 8.5 0.1 8.8 8 07/10/2006 10:00:00 12.3 1.1 14.9 9.9 12.3 1.1 14.9 9.9 12.2 1.1 15.3 9.5 136 6 133 165 8.3 0 8.5 8 07/10/2006 10:10:00 11.8 1.3 14.5 8.4 11.8 1.3 14.9 8.4 11.4 1.3 14.5 8 134 7 129 165 8.4 0 8.5 8.3 07/10/2006 10:20:00 10.5 0.8 12.6 7.6 10.6 0.9 12.6 8 10.4 1 13 6.8 134 6 136 165 8.4 0 8.5 8.3 07/10/2006 10:30:00 9.9 1.1 13 7.2 10.1 1 13 7.6 9.8 1.1 12.6 6.1 130 7 126 165 8.4 0 8.5 8.3 07/10/2006 10:40:00 9.2 1.1 12.2 6.8 9.4 1.1 12.2 6.5 9.1 1.1 11.8 6.8 125 7 116 165 8.5 0 8.5 8.3 07/10/2006 10:50:00 9.7 1.3 13 6.5 9.9 1.3 13.3 6.8 9.6 1.3 13.3 6.1 124 7 113 165 8.4 0 8.5 8.3 07/10/2006 11:00:00 10.3 1.1 13.3 7.6 10.4 1.1 13.3 7.6 10 1.1 13.3 6.8 126 7 126 165 8.4 0 9 8.3 07/10/2006 11:10:00 11.1 1.1 13.7 7.6 11.2 1.1 14.1 7.6 11 1.3 14.5 7.6 131 7 128 165 8.4 0 8.5 8.3 07/10/2006 11:20:00 10.9 1.2 13.7 6.8 11 1.2 13.7 7.2 10.8 1.3 13.7 7.2 133 7 125 165 8.3 0 8.5 8.3 07/10/2006 11:30:00 10.5 1.1 14.1 6.5 10.7 1.1 14.5 6.8 10.3 1.2 13 6.1 127 6 125 165 8.3 0 8.8 8.3 07/10/2006 11:40:00 11.3 1.4 14.1 6.5 11.4 1.5 14.1 7.2 11 1.5 13.7 6.8 126 6 121 165 8.4 0 8.8 8.3 07/10/2006 11:50:00 10.1 1.1 13.3 7.6 10.3 1.1 13.7 8 9.8 1.1 13.7 6.5 123 6 121 165 8.4 0 8.8 8.3 07/10/2006 12:00:00 10.2 1.1 12.6 7.6 10.4 1 12.6 8 10 1 12.2 7.2 126 7 125 165 8.5 0 8.5 8.3 07/10/2006 12:10:00 10.6 1.6 14.9 8 10.8 1.6 15.3 8 10.4 1.5 15.3 7.6 125 6 119 165 8.5 0 8.5 8.3 07/10/2006 12:20:00 10.6 1.3 14.1 7.6 10.9 1.3 14.5 7.6 10.2 1.3 13.7 7.6 120 8 114 165 8.5 0 8.5 8.3 07/10/2006 12:30:00 9.6 1.3 13.7 6.1 9.8 1.3 13.7 6.5 9.2 1.3 13.3 5.7 111 6 120 165 8.6 0 8.8 8.5 07/10/2006 12:40:00 9.9 0.9 12.2 6.8 10.1 0.9 12.6 6.8 9.3 1 12.2 6.5 112 6 110 165 8.7 0 8.8 8.5 07/10/2006 12:50:00 10 1.1 12.6 7.2 10.2 1.1 13 7.2 9.5 1.2 12.2 6.1 116 7 114 165 8.6 0 8.8 8.3 07/10/2006 13:00:00 9.3 0.9 11.5 6.8 9.5 1 11.8 6.8 8.9 1 11.5 6.5 111 7 116 165 8.7 0 8.8 8.3 07/10/2006 13:10:00 10.7 1.3 14.5 6.5 10.9 1.3 15.3 6.5 10.1 1.4 14.5 6.1 106 6 101 165 8.7 0 9 8.5 07/10/2006 13:20:00 10.7 1.2 14.5 8 10.9 1.3 14.9 8 10.1 1.3 14.1 6.8 108 5 110 165 8.6 0 8.8 8.5 07/10/2006 13:30:00 10.8 1.2 13.3 7.2 11 1.2 13.7 6.8 10.3 1.3 13.7 6.5 110 6 112 165 8.6 0 8.8 8.5 07/10/2006 13:40:00 10.7 1.3 14.1 7.2 10.9 1.4 14.5 6.8 9.9 1.5 14.9 6.5 111 7 111 165 8.7 0 8.8 8.5 07/10/2006 13:50:00 11.5 1.2 15.6 8 11.7 1.2 16.1 7.6 10.8 1.3 15.3 7.6 112 6 109 165 8.7 0 8.8 8.5 07/10/2006 14:00:00 10.8 1.3 14.1 6.8 11 1.4 14.1 7.6 10.1 1.4 14.1 7.2 113 8 108 165 8.7 0 9 8.5 07/10/2006 14:10:00 10.6 1.5 14.5 6.8 10.7 1.5 15.3 6.8 9.7 1.5 14.1 6.8 112 8 105 165 8.7 0 9 8.5 07/10/2006 14:20:00 10.6 1.3 14.9 6.5 10.9 1.3 14.5 6.1 10.1 1.3 13.3 6.5 109 8 97 165 8.7 0 8.8 8.5 07/10/2006 14:30:00 11.3 1.3 14.5 6.5 11.5 1.3 14.9 6.5 10.6 1.4 14.5 6.8 111 6 106 165 8.7 0 8.8 8.5 07/10/2006 14:40:00 11.2 1.2 14.1 6.8 11.4 1.3 14.9 5.7 10.4 1.3 13.3 6.8 110 7 121 165 8.7 0 8.8 8.5 07/10/2006 14:50:00 11.7 1 14.1 9.1 11.9 1 14.9 9.1 11 1.3 14.1 8 106 5 106 165 8.7 0 9 8.5 07/10/2006 15:00:00 11.6 1.3 14.9 7.6 11.9 1.3 15.6 8 10.9 1.4 14.5 6.8 107 6 111 165 8.7 0 8.8 8.5 07/10/2006 15:10:00 11.5 1.2 14.5 8 11.7 1.3 14.9 6.8 10.8 1.5 14.1 5.7 111 7 122 165 8.7 0 8.8 8.5 07/10/2006 15:20:00 11.8 1.4 14.5 6.5 12.1 1.4 14.9 6.8 11.1 1.4 15.3 6.5 112 7 110 165 8.7 0 8.8 8.5 07/10/2006 15:30:00 11.4 1.2 15.6 8 11.6 1.2 16.1 8 10.6 1.3 13.7 7.2 110 7 118 165 8.8 0 8.8 8.8 07/10/2006 15:40:00 12.2 1.2 15.6 8.8 12.4 1.2 16.1 8.8 11.4 1.2 14.9 8 108 6 110 165 8.8 0 9 8.8 07/10/2006 15:50:00 12.5 1.3 16.1 9.1 12.7 1.3 16.8 9.1 11.8 1.5 16.4 7.2 108 6 108 165 8.8 0 9.3 8.8 07/10/2006 16:00:00 12.5 1.4 16.8 9.1 12.8 1.4 16.8 9.1 11.7 1.5 16.1 7.6 108 6 105 165 8.8 0 8.8 8.8 07/10/2006 16:10:00 12.3 1.3 16.1 8.8 12.5 1.3 16.4 9.1 11.5 1.5 16.1 8 110 6 112 165 8.8 0 8.8 8.8 07/10/2006 16:20:00 12.2 1.2 14.9 8.4 12.5 1.2 14.9 8.8 11.6 1.3 15.3 7.2 108 7 104 165 8.8 0 8.8 8.5 07/10/2006 16:30:00 12.5 1.2 14.9 9.1 12.8 1.2 15.3 9.9 11.9 1.3 14.9 7.6 106 6 102 165 8.8 0 8.8 8.8 07/10/2006 16:40:00 12.5 1.2 16.1 9.1 12.7 1.2 16.4 9.1 11.5 1.4 16.1 6.5 110 6 108 165 8.8 0 9 8.8 07/10/2006 16:50:00 12.3 1.5 15.3 8.4 12.6 1.5 15.6 8.4 11.7 1.7 16.1 8 111 6 114 165 8.9 0 9 8.5 07/10/2006 17:00:00 12.1 1.5 16.4 8 12.4 1.6 16.8 8 11.3 1.7 16.1 7.6 113 8 116 165 8.9 0 9 8.8 07/10/2006 17:10:00 12.2 1.6 16.8 8.4 12.4 1.6 17.6 8 11.4 1.7 16.8 7.2 113 7 111 165 8.9 0 9.3 8.8 07/10/2006 17:20:00 12.1 1.3 15.3 8.8 12.4 1.5 15.3 8.8 11.4 1.5 15.3 7.6 111 7 135 165 8.9 0 9 8.8 07/10/2006 17:30:00 12 1.3 15.3 6.8 12.2 1.3 15.3 7.2 11.1 1.5 14.9 6.8 110 6 101 165 8.9 0 9 8.8 07/10/2006 17:40:00 12.5 1.3 16.4 8.8 12.7 1.3 16.4 8.4 11.7 1.4 14.5 7.2 112 7 121 165 8.9 0 9.3 8.8 07/10/2006 17:50:00 13.4 1.3 16.8 8.8 13.6 1.3 17.2 9.1 12.7 1.5 16.4 8.8 114 6 112 165 8.9 0 9 8.8 07/10/2006 18:00:00 13.1 1.2 17.2 9.1 13.4 1.2 17.6 9.5 12.5 1.4 16.8 8.4 115 7 115 165 8.9 0 9 8.8 07/10/2006 18:10:00 13.4 1.3 16.8 9.9 13.7 1.3 16.4 10.3 12.5 1.3 15.6 9.1 115 5 114 165 8.9 0 9.3 8.8 07/10/2006 18:20:00 13.5 1.7 18.3 8.4 13.7 1.7 17.9 7.6 12.8 1.7 16.8 7.6 115 7 118 165 8.9 0 9 8.8 07/10/2006 18:30:00 13 1.5 16.8 8.8 13.2 1.5 17.2 9.1 12.3 1.6 16.8 8.4 114 7 116 165 8.9 0 9.3 8.8 07/10/2006 18:40:00 13.6 1.5 19.1 9.1 13.9 1.5 19.9 9.9 13 1.7 17.2 8.4 115 7 114 165 8.9 0 9.3 8.8 07/10/2006 18:50:00 13.8 1.5 17.2 9.5 14 1.6 17.6 9.5 12.9 1.8 17.2 7.6 114 8 117 165 8.9 0 9 8.5 07/10/2006 19:00:00 14.4 1.2 17.6 10.3 14.7 1.2 18.3 10.7 13.6 1.5 17.9 9.5 112 6 112 165 8.9 0 9 8.8 07/10/2006 19:10:00 13.8 1.4 17.2 9.5 14 1.5 17.6 9.9 12.9 1.5 17.9 9.1 111 7 112 165 8.9 0 9 8.8 07/10/2006 19:20:00 14.6 1.5 19.1 10.3 14.9 1.5 19.9 11.1 13.8 1.7 18.7 9.5 111 5 101 165 8.9 0 9 8.5 07/10/2006 19:30:00 14.6 1.3 17.9 9.9 14.8 1.3 17.9 9.9 13.8 1.5 17.6 8.8 110 5 106 165 8.9 0 9 8.8 07/10/2006 19:40:00 14.5 1.4 17.6 10.7 14.7 1.5 17.9 11.1 13.5 1.6 17.9 8.4 111 5 111 165 8.9 0 9.3 8.8 07/10/2006 19:50:00 14.8 1.5 17.9 9.9 15 1.6 18.7 9.9 14 1.7 18.3 8.8 109 6 106 165 8.9 0 9 8.8 07/10/2006 20:00:00 15.1 1.3 19.5 11.5 15.4 1.3 19.5 11.5 14.3 1.5 18.7 8.8 108 6 111 165 8.9 0 9.6 9 07/10/2006 20:10:00 14.9 1.5 18.7 9.5 15.1 1.6 19.1 9.9 14.1 1.7 17.9 9.1 107 6 113 165 8.9 0 9 8.8 07/10/2006 20:20:00 15.1 1.6 19.1 11.1 15.4 1.6 19.1 11.1 14.1 1.7 18.3 9.1 107 5 106 165 8.9 0 9 9 07/10/2006 20:30:00 15.5 1.5 19.1 11.1 15.8 1.6 19.9 10.3 14.6 1.7 18.3 9.9 108 6 103 165 9 0 9 9 07/10/2006 20:40:00 15.4 1.6 19.5 9.5 15.7 1.6 19.9 9.9 14.4 1.8 18.7 9.5 107 6 104 165 9 0 9 9 07/10/2006 20:50:00 15.6 1.4 20.2 12.2 15.9 1.4 19.9 11.8 14.6 1.6 18.3 9.9 106 6 113 165 9 0 9 9 07/10/2006 21:00:00 15.2 1.5 18.7 11.8 15.5 1.5 19.1 11.5 14.2 1.7 18.3 9.1 108 6 114 165 9 0 9 9 07/10/2006 21:10:00 15.2 1.2 17.9 11.1 15.4 1.2 18.3 11.8 14.3 1.3 17.9 8.8 107 6 112 165 9.1 0 9.6 9 07/10/2006 21:20:00 15.6 1.5 19.1 11.8 15.9 1.5 19.1 11.8 14.8 1.7 18.3 10.7 106 6 106 165 9.1 0 9.3 9 07/10/2006 21:30:00 15.4 1.7 18.7 9.1 15.6 1.7 19.5 10.7 14.2 1.7 17.9 9.1 108 6 109 165 9.1 0 9.3 9 07/10/2006 21:40:00 15 1.7 19.1 10.3 15.3 1.8 19.1 9.5 14 1.9 18.3 9.1 107 7 110 165 9.1 0 9.6 9 07/10/2006 21:50:00 15.4 1.4 20.6 10.3 15.8 1.4 20.2 10.3 14.7 1.5 20.2 10.7 108 6 101 165 9.2 0 9.3 9 07/10/2006 22:00:00 15.4 1.6 19.1 10.7 15.6 1.7 19.1 10.7 14.6 1.8 19.1 9.5 107 6 109 165 9.2 0 9.6 8.8 07/10/2006 22:10:00 15.4 1.6 18.7 10.3 15.6 1.6 19.5 10.7 14.3 1.8 18.3 9.1 107 6 107 165 9.2 0 9.3 9 07/10/2006 22:20:00 15.4 1.3 18.7 11.5 15.7 1.3 18.7 11.5 14.4 1.4 17.6 9.5 106 6 108 165 9.2 0 9.6 9 07/10/2006 22:30:00 15.3 1.3 18.3 11.5 15.6 1.3 18.3 11.8 14.4 1.5 18.7 9.9 106 5 113 165 9.2 0 9.8 9 07/10/2006 22:40:00 15.7 1.3 18.7 11.1 16.1 1.3 19.5 11.8 14.9 1.5 18.7 10.3 105 6 101 165 9.3 0 9.3 9 07/10/2006 22:50:00 15.2 1.6 20.2 9.5 15.5 1.6 19.9 9.9 14.4 1.7 18.3 9.5 107 6 99 165 9.3 0 9.3 9 07/10/2006 23:00:00 15.1 1.4 18.3 10.7 15.4 1.5 18.7 10.7 14.2 1.6 17.6 9.1 105 6 104 165 9.3 0 9.3 9 07/10/2006 23:10:00 15.6 1.3 19.1 10.7 15.9 1.3 19.1 11.5 14.4 1.5 18.7 9.5 106 6 93 165 9.4 0 9.3 9 07/10/2006 23:20:00 15.5 1.7 19.9 11.5 15.8 1.7 20.6 11.5 14.6 1.7 18.7 9.1 105 6 101 165 9.4 0 9.3 9 07/10/2006 23:30:00 15.9 1.7 19.5 10.7 16.3 1.7 19.9 10.3 15 1.8 19.1 9.9 102 6 108 165 9.4 0 9.6 9 07/10/2006 23:40:00 15.7 1.6 19.5 10.7 16 1.6 19.9 10.7 14.9 1.7 19.5 9.9 104 6 102 165 9.4 0 9.6 9 07/10/2006 23:50:00 16.3 1.7 20.6 11.5 16.6 1.7 21 11.5 15.3 1.8 19.9 11.1 104 5 106 165 9.4 0 9.6 9.3 07/11/2006 00:00:00 16.3 1.7 20.2 10.7 16.6 1.8 20.2 10.7 15.3 1.8 19.9 9.5 103 6 107 165 9.4 0 9.8 9.3 07/11/2006 00:10:00 15.7 1.7 19.9 9.5 16 1.8 19.9 10.3 14.7 1.9 18.3 9.1 104 6 110 165 9.4 0 9.6 9.3 07/11/2006 00:20:00 15.9 1.6 19.9 10.7 16.3 1.6 21 10.7 14.8 1.7 19.1 9.9 104 6 98 165 9.4 0 9.6 9.3 07/11/2006 00:30:00 15.8 1.7 20.2 11.1 16.1 1.7 20.6 11.5 14.9 1.7 19.9 9.1 105 6 108 165 9.4 0 9.8 9.3 07/11/2006 00:40:00 15.9 1.6 19.5 11.5 16.2 1.6 19.9 11.1 14.9 1.7 19.1 9.9 103 6 101 165 9.4 0 9.6 9.3 07/11/2006 00:50:00 16.1 1.6 19.5 11.8 16.4 1.6 20.2 11.8 15.2 1.8 19.9 11.1 104 6 105 165 9.4 0 9.8 9.3 07/11/2006 01:00:00 16.4 1.6 19.1 10.7 16.7 1.7 19.5 10.7 15.2 1.7 19.1 10.7 103 7 105 165 9.4 0 9.6 9.3 07/11/2006 01:10:00 16.8 1.4 20.2 12.6 17.1 1.5 20.6 12.6 16.1 1.5 20.2 11.1 102 6 106 165 9.4 0 9.8 9.3 07/11/2006 01:20:00 16.2 1.7 21.4 11.5 16.6 1.7 21.8 11.1 15.2 1.8 21.8 10.7 101 6 104 165 9.4 0 9.6 9.3 07/11/2006 01:30:00 16.3 1.7 20.6 11.1 16.7 1.7 21.4 12.2 15.6 1.8 20.6 10.3 103 7 111 165 9.4 0 9.6 9.3 07/11/2006 01:40:00 16.3 1.4 19.9 11.5 16.7 1.5 20.6 11.8 15.1 1.8 18.7 10.3 101 6 99 165 9.4 0 9.6 9.3 07/11/2006 01:50:00 15.7 1.5 19.1 9.9 16 1.6 19.9 11.5 14.6 1.7 19.5 9.1 100 6 97 165 9.4 0 9.6 9.3 07/11/2006 02:00:00 15 1.6 19.1 10.3 15.3 1.6 19.5 10.7 13.8 1.7 18.3 9.5 99 7 94 165 9.4 0 9.6 9.3 07/11/2006 02:10:00 15.7 1.5 19.9 11.5 16 1.5 20.2 12.2 14.6 1.7 19.9 10.3 98 7 99 165 9.4 0 9.6 9.3 07/11/2006 02:20:00 15.4 1.4 19.1 10.7 15.7 1.4 19.1 11.1 14.3 1.6 17.9 9.1 100 7 88 165 9.4 0 9.6 9.3 07/11/2006 02:30:00 15.2 1.8 19.5 9.9 15.5 1.8 19.5 9.9 14.3 2 18.7 9.1 100 6 96 165 9.4 0 9.6 9.3 07/11/2006 02:40:00 14.6 1.5 17.6 9.9 14.9 1.5 18.3 9.9 13.7 1.7 17.6 8.8 100 7 101 165 9.4 0 9.6 9 07/11/2006 02:50:00 14.8 1.4 17.9 10.3 15.1 1.4 18.3 10.7 13.8 1.5 17.9 9.9 99 6 104 165 9.4 0 9.6 9.3 07/11/2006 03:00:00 14.6 1.7 19.5 9.9 15 1.7 20.6 9.9 13.8 1.8 18.3 9.5 99 6 96 165 9.4 0 9.6 9.3 07/11/2006 03:10:00 14.6 1.2 18.3 10.7 14.9 1.2 18.3 11.1 13.7 1.5 17.2 9.1 99 7 107 165 9.4 0 9.8 9 07/11/2006 03:20:00 14.6 1.7 19.1 9.9 14.9 1.7 19.1 9.9 13.7 1.9 19.1 8.8 100 7 98 165 9.4 0 9.6 9 07/11/2006 03:30:00 14.4 1.5 17.9 9.9 14.7 1.5 18.7 10.7 13.4 1.7 16.8 9.1 100 8 120 165 9.4 0 9.6 9 07/11/2006 03:40:00 14.6 1.8 18.7 9.5 14.9 1.8 19.5 9.9 13.8 2 18.3 8.8 99 7 106 165 9.4 0 9.6 9 07/11/2006 03:50:00 14.9 1.5 18.3 9.5 15.2 1.5 18.7 9.5 13.9 1.6 17.9 9.1 99 7 99 165 9.4 0 9.6 9 07/11/2006 04:00:00 14.8 1.5 19.1 9.9 15.2 1.6 19.5 10.7 13.9 1.7 19.1 9.1 99 6 99 165 9.4 0 9.6 9 07/11/2006 04:10:00 14.4 1.5 17.9 9.5 14.7 1.6 18.7 9.9 13.5 1.7 17.6 9.1 98 7 101 165 9.4 0 9.6 9.3 07/11/2006 04:20:00 14.1 1.6 17.6 9.1 14.4 1.6 17.9 9.9 13.1 1.6 16.8 9.1 97 7 101 165 9.3 0 9.3 9 07/11/2006 04:30:00 14.7 1.5 18.7 10.7 15 1.5 19.1 10.7 13.9 1.7 18.3 9.9 99 7 104 165 9.2 0 9.6 9 07/11/2006 04:40:00 15.1 1.5 19.1 10.7 15.4 1.6 19.1 9.5 14.1 1.8 19.1 8.8 98 7 101 165 9.2 0 9.6 9 07/11/2006 04:50:00 14.5 1.5 17.2 9.5 14.8 1.5 17.6 10.3 13.4 1.6 16.8 9.5 96 7 87 165 9.2 0 9.6 9 07/11/2006 05:00:00 14.7 1.6 19.5 9.9 15 1.7 19.5 9.9 13.6 1.7 19.1 9.5 95 7 100 165 9.3 0 9.3 9 07/11/2006 05:10:00 14.8 1.7 18.3 9.1 15.1 1.7 18.3 9.9 13.9 1.8 18.3 9.1 93 6 98 165 9.3 0 9.8 9 07/11/2006 05:20:00 14.9 1.5 18.3 9.9 15.2 1.6 18.7 10.7 14 1.5 18.3 8.8 92 6 97 165 9.3 0 9.3 9.3 07/11/2006 05:30:00 15.4 1.5 18.3 9.5 15.7 1.5 18.3 9.5 14.3 1.7 17.9 9.5 92 6 90 165 9.3 0 9.6 9.3 07/11/2006 05:40:00 14.9 1.8 18.3 9.5 15.2 1.9 18.7 9.5 14.1 1.8 17.6 7.2 91 7 102 165 9.3 0 9.3 9 07/11/2006 05:50:00 15.6 1.5 18.7 10.7 15.9 1.5 19.5 10.3 14.7 1.5 18.3 9.5 91 6 99 165 9.4 0 9.3 9.3 07/11/2006 06:00:00 15.8 1.6 19.1 10.7 16.2 1.7 19.9 10.3 14.8 1.7 19.1 9.5 92 6 92 165 9.4 0 9.3 9.3 07/11/2006 06:10:00 16.1 1.7 19.1 11.5 16.4 1.7 19.5 11.1 15.3 1.7 19.1 9.9 89 6 91 165 9.4 0 9.3 9.3 07/11/2006 06:20:00 16.1 1.5 19.1 10.7 16.4 1.5 19.9 10.7 15.2 1.7 19.5 10.7 89 6 87 165 9.4 0 9.6 9 07/11/2006 06:30:00 15.7 1.7 19.5 9.9 16 1.7 19.5 9.9 14.6 1.7 18.7 10.3 89 6 92 165 9.4 0 9.6 9 07/11/2006 06:40:00 16.2 1.4 19.1 11.5 16.6 1.5 19.5 11.5 15.3 1.5 18.7 11.1 87 6 90 165 9.4 0 9.6 9 07/11/2006 06:50:00 15.6 1.5 19.1 10.7 15.9 1.6 19.5 10.7 14.9 1.5 17.9 11.1 87 6 90 165 9.4 0 9.6 9.3 07/11/2006 07:00:00 15.6 1.3 18.7 11.1 16 1.5 18.7 10.7 14.8 1.5 17.9 9.1 88 6 102 165 9.4 0 9.6 9 07/11/2006 07:10:00 16 1.6 18.7 10.7 16.3 1.7 19.1 11.1 15.1 1.7 18.3 10.3 87 5 84 165 9.5 0 9.8 9.3 07/11/2006 07:20:00 15.4 1.5 18.3 10.7 15.7 1.5 18.7 11.1 14.7 1.4 18.3 9.9 86 6 91 165 9.5 0 9.6 9 07/11/2006 07:30:00 15.7 1.5 19.1 11.8 16 1.5 19.5 11.8 14.8 1.7 19.1 10.7 86 6 84 165 9.5 0 9.8 9.3 07/11/2006 07:40:00 15 1.7 19.1 10.3 15.3 1.7 19.5 10.7 14.4 1.7 17.9 9.9 85 6 89 165 9.6 0 9.6 9.3 07/11/2006 07:50:00 14.8 1.3 18.3 11.5 15.1 1.4 18.7 10.7 13.8 1.6 17.2 8.8 85 6 84 165 9.6 0 9.6 9.3 07/11/2006 08:00:00 14 1.5 17.9 9.1 14.3 1.5 17.9 9.1 13.3 1.5 17.6 9.5 84 7 84 165 9.6 0 9.6 9.3 07/11/2006 08:10:00 14.5 1.7 17.9 9.9 14.8 1.7 18.7 9.9 13.9 1.6 17.6 9.1 85 6 90 165 9.6 0 10.1 9.3 07/11/2006 08:20:00 14.3 1.5 18.7 10.3 14.6 1.6 18.7 10.3 13.5 1.5 16.8 9.1 85 6 87 165 9.6 0 10.1 9.3 07/11/2006 08:30:00 14.7 1.7 17.9 9.9 15 1.7 18.3 9.9 13.9 1.7 18.7 9.5 85 6 91 165 9.6 0 10.1 9.6 07/11/2006 08:40:00 14 1.4 17.2 9.9 14.4 1.5 17.6 10.3 13.4 1.5 17.6 9.9 82 7 85 165 9.6 0 9.6 9.6 07/11/2006 08:50:00 14.6 1.4 17.6 10.3 14.9 1.5 17.9 10.7 14 1.5 16.8 9.9 81 6 82 165 9.6 0 9.8 9.6 07/11/2006 09:00:00 14.4 1.4 17.6 9.9 14.7 1.5 18.3 10.3 13.5 1.5 16.4 9.1 80 6 78 165 9.6 0 9.8 9.6 07/11/2006 09:10:00 14.2 1.5 17.6 10.3 14.5 1.6 18.3 10.3 13.5 1.7 17.2 8.4 81 7 81 165 9.6 0 10.3 9.6 07/11/2006 09:20:00 14.4 1.5 18.3 10.3 14.7 1.7 18.7 10.3 13.7 1.7 17.2 9.9 81 7 84 165 9.6 0 9.8 9.6 07/11/2006 09:30:00 14.6 1.5 18.3 9.1 14.9 1.5 18.7 9.5 13.9 1.5 17.2 9.5 82 7 83 165 9.6 0 9.8 9.6 07/11/2006 09:40:00 15.1 1.7 18.7 10.3 15.4 1.7 19.1 10.7 14.3 1.5 17.9 10.3 81 8 83 165 9.6 0 10.1 9.6 07/11/2006 09:50:00 15.1 1.7 18.7 10.7 15.4 1.7 18.7 10.7 14.4 1.6 18.3 9.9 81 7 86 165 9.6 0 9.8 9.6 07/11/2006 10:00:00 14.1 1.9 18.3 9.1 14.4 2 18.7 8.8 13.7 1.7 17.6 8.4 79 7 81 165 9.6 0.1 9.8 9 07/11/2006 10:10:00 14.5 1.5 18.3 11.1 14.8 1.6 18.3 10.7 13.8 1.6 17.9 9.9 80 7 83 165 9.6 0 9.8 9.6 07/11/2006 10:20:00 14.3 1.7 18.3 9.9 14.6 1.8 18.3 10.3 13.6 1.7 18.3 8.8 79 7 88 165 9.6 0 9.8 9.6 07/11/2006 10:30:00 14.9 1.9 20.2 9.9 15.2 2 20.6 10.3 14.3 1.9 19.9 9.5 79 7 81 165 9.6 0 10.3 9.6 07/11/2006 10:40:00 13.9 1.7 18.3 9.9 14.2 1.8 18.7 9.9 13.5 1.8 18.3 9.1 79 8 80 165 9.6 0 9.8 9 07/11/2006 10:50:00 13.4 1.9 17.6 8.8 13.8 1.9 17.6 8.8 13 1.8 17.2 9.1 79 8 90 165 9.6 0 9.8 9 07/11/2006 11:00:00 12.3 1.6 16.8 8.4 12.5 1.7 17.2 8.4 12 1.6 17.2 8.8 76 9 81 165 9.6 0 9.6 9.3 07/11/2006 11:10:00 11.9 1.6 16.8 8.4 12.2 1.7 17.6 8 11.6 1.7 16.4 7.6 77 10 83 165 9.6 0.1 9.8 9 07/11/2006 11:20:00 12.5 1.8 17.2 8 12.8 1.9 17.6 8 12.2 1.9 17.2 7.2 78 9 79 165 9.6 0 9.6 9 07/11/2006 11:30:00 12.5 2 17.9 7.6 12.8 2.1 17.6 7.6 12.1 2 16.8 6.8 78 9 81 165 9.6 0 9.6 9.3 07/11/2006 11:40:00 12.3 1.7 16.8 8 12.6 1.7 17.2 8.4 12.1 1.7 16.8 8.4 77 9 77 165 9.6 0 9.6 9.6 07/11/2006 11:50:00 12.1 1.7 16.8 7.6 12.4 1.7 17.2 8 11.8 1.6 16.4 7.2 75 9 81 165 9.6 0 9.6 9.6 07/11/2006 12:00:00 11.5 1.8 16.1 7.2 11.7 2 16.1 6.8 11.1 1.8 16.1 7.2 76 9 77 165 9.6 0.1 9.8 9 07/11/2006 12:10:00 12.4 1.7 16.1 7.6 12.7 1.8 16.4 7.6 12 1.8 16.1 7.2 76 9 74 165 9.6 0.1 9.8 9 07/11/2006 12:20:00 13.3 1.7 17.6 8.4 13.6 1.8 17.6 8.4 12.9 1.7 16.8 8 78 8 78 165 9.6 0.1 9.8 9 07/11/2006 12:30:00 11.6 2 16.4 6.8 11.9 2.1 16.8 7.2 11.4 1.9 16.4 6.8 76 9 81 165 9.7 0 10.1 9 07/11/2006 12:40:00 10.5 2 16.1 6.5 10.7 2.1 16.4 6.1 10.1 1.9 14.1 5.7 73 10 75 165 9.8 0 10.1 9.3 07/11/2006 12:50:00 9.7 1.6 13.7 5.7 9.8 1.7 13.7 5.7 9.3 1.5 13.3 5.3 73 10 78 165 9.8 0 10.1 9.3 07/11/2006 13:00:00 10.7 2 16.4 6.1 10.9 2.1 16.8 6.1 10.3 1.7 15.3 6.8 76 10 95 165 9.8 0 10.3 9.6 07/11/2006 13:10:00 9.9 1.8 14.1 6.1 10.1 1.9 14.5 6.1 9.6 1.7 14.9 6.1 75 10 79 165 9.8 0 10.1 9.6 07/11/2006 13:20:00 10.2 1.7 14.5 5.7 10.3 1.7 14.9 5.3 9.7 1.4 13 6.5 71 10 56 165 9.9 0 10.1 9.6 07/11/2006 13:30:00 10.2 1.5 15.3 6.8 10.4 1.7 15.3 6.8 9.9 1.5 14.1 6.1 75 10 86 165 9.9 0 10.3 9.6 07/11/2006 13:40:00 10.8 1.7 16.1 6.5 11.1 1.7 16.4 6.8 10.4 1.7 15.6 6.5 75 10 70 165 9.9 0 9.8 9.6 07/11/2006 13:50:00 9.7 1.5 14.9 6.8 9.9 1.7 15.3 6.5 9.3 1.5 14.5 6.1 72 9 85 165 9.9 0 10.1 9.6 07/11/2006 14:00:00 9.4 1.8 13.7 5.3 9.5 2 14.1 4.9 9 1.8 13.3 5.3 68 12 64 165 10 0 10.3 9.6 07/11/2006 14:10:00 9.4 1.2 13 6.1 9.4 1.3 13 5.7 9.1 1.3 13 6.1 66 10 87 165 10 0 10.3 9.6 07/11/2006 14:20:00 9.6 2.1 15.3 5.3 9.7 2.2 16.1 4.9 9.3 1.9 15.3 5.7 65 10 74 165 10 0 10.1 9.6 07/11/2006 14:30:00 9.3 1.8 13.7 4.9 9.4 1.9 13.7 4.6 9.1 1.6 13.3 4.9 66 11 69 165 10 0 10.6 9.6 07/11/2006 14:40:00 9.7 1.5 13.3 6.1 9.8 1.6 13.7 6.1 9.5 1.6 13.3 6.1 66 10 75 165 10 0 10.6 9.6 07/11/2006 14:50:00 9.9 1.7 13.7 6.1 10 1.7 14.9 6.1 9.7 1.6 13.7 6.1 68 11 72 165 10.1 0 10.3 9.6 07/11/2006 15:00:00 9.6 1.6 16.1 6.1 9.6 1.7 16.1 6.1 9.2 1.7 14.1 5.3 67 10 68 165 10 0 10.6 9.6 07/11/2006 15:10:00 9 1.7 13.7 5.3 9.1 1.8 14.1 5.3 8.8 1.6 13 4.9 67 10 80 165 10.1 0.1 10.3 9.6 07/11/2006 15:20:00 9.8 1.7 15.3 4.9 9.9 1.8 16.1 5.3 9.5 1.6 13.7 6.1 67 10 73 165 10 0 10.3 9.3 07/11/2006 15:30:00 9.2 1.5 13.3 5.7 9.3 1.6 13.7 5.7 9 1.6 13.3 4.9 66 11 78 165 9.9 0 10.1 9.3 07/11/2006 15:40:00 8.9 1.6 13 5.3 9 1.7 13.7 5.7 8.6 1.5 12.6 5.3 66 10 77 165 9.9 0.1 10.1 9.3 07/11/2006 15:50:00 9.4 1.7 15.6 6.1 9.5 1.8 16.1 6.1 9.2 1.7 14.5 5.3 68 11 72 165 9.7 0.1 9.8 9.3 07/11/2006 16:00:00 8 1.8 14.5 3.8 8.1 1.9 14.5 3.8 7.5 1.7 13.3 4.6 62 12 85 165 9.9 0 10.1 9.6 07/11/2006 16:10:00 7.8 1.8 13.3 3.4 7.9 1.9 14.1 3.4 7.6 1.8 13 3.8 61 11 63 165 10 0.1 10.3 9.6 07/11/2006 16:20:00 8.9 1.7 15.3 4.9 9 1.7 14.9 4.6 8.7 1.5 12.6 4.6 70 11 72 165 10 0.1 10.3 9.3 07/11/2006 16:30:00 8.6 1.7 13 4.6 8.7 1.7 13.3 4.6 8.3 1.5 13 4.6 64 11 75 165 10 0.1 10.3 9.6 07/11/2006 16:40:00 7.5 1.7 12.2 3.8 7.5 1.7 11.8 4.2 7.3 1.6 12.2 4.6 58 13 65 165 10 0.1 10.6 9.6 07/11/2006 16:50:00 8.9 2 14.1 5.7 8.9 2.1 14.5 5.3 8.4 1.8 13.7 4.9 60 11 65 165 10 0.1 10.3 9.6 07/11/2006 17:00:00 7.5 1.7 11.5 3.8 7.6 1.7 11.5 3.8 7.5 1.6 11.5 4.6 65 12 60 165 10 0.2 10.3 9.6 07/11/2006 17:10:00 8.3 1.9 13.7 3 8.4 1.9 13.7 3.8 8.2 1.7 12.6 4.9 68 12 92 165 10 0.2 10.6 9.3 07/11/2006 17:20:00 8.8 1.5 13 5.3 8.9 1.7 13 5.3 8.5 1.3 12.2 5.3 63 14 63 165 9.9 0.1 10.1 9.3 07/11/2006 17:30:00 8.5 1.9 14.5 4.2 8.7 2 14.9 4.2 8.2 1.9 14.5 4.6 63 11 56 165 10 0.1 10.6 9.3 07/11/2006 17:40:00 6.6 1.8 11.1 3.4 6.7 1.8 11.5 3 6.6 1.7 11.1 3.4 57 12 61 165 10 0.2 10.6 9.6 07/11/2006 17:50:00 5.6 1.4 9.5 2.6 5.7 1.4 9.5 2.6 5.7 1.3 9.9 3 59 12 57 165 10 0 10.3 9.6 07/11/2006 18:00:00 5.3 1.1 8.4 3 5.4 1.1 8.8 3 5.2 1 8.8 3 56 11 70 165 10 0 10.3 9.6 07/11/2006 18:10:00 5.7 1.4 9.5 3 5.8 1.4 9.9 3 5.7 1.2 10.3 3 55 12 70 165 10 0 10.3 9.6 07/11/2006 18:20:00 5.5 1 8 3 5.5 1 7.6 2.6 5.3 0.9 8 3 49 11 43 165 10 0 10.1 9.6 07/11/2006 18:30:00 7.7 1.2 11.1 4.9 7.7 1.3 10.7 4.6 7.5 1.3 11.5 4.9 43 7 41 165 10 0 10.3 9.6 07/11/2006 18:40:00 7.8 1.1 10.3 4.9 7.7 1.2 10.7 4.6 7.5 1.1 10.3 4.6 46 8 33 165 9.9 0 10.1 9.6 07/11/2006 18:50:00 7.7 1.1 10.7 4.6 7.6 1.1 11.1 4.9 7.3 1 10.7 4.6 46 9 53 165 10 0 10.1 9.6 07/11/2006 19:00:00 7.3 1 9.5 4.6 7.3 1 9.5 4.6 7 1 9.5 4.2 46 8 43 165 10 0 10.1 9.6 07/11/2006 19:10:00 6.7 1 9.1 4.2 6.7 1 9.1 4.2 6.5 1 9.1 3.8 49 8 44 165 10 0 10.3 9.6 07/11/2006 19:20:00 7.3 1.1 11.1 3.4 7.3 1.2 11.1 3.8 7.1 1.1 10.3 3.8 49 9 69 165 9.9 0 10.1 9.6 07/11/2006 19:30:00 7.6 0.8 9.5 4.6 7.6 0.8 9.5 4.9 7.6 0.9 9.9 4.9 41 7 45 165 9.9 0 10.3 9.6 07/11/2006 19:40:00 7.5 0.6 9.5 6.1 7.5 0.6 9.1 5.7 7.3 0.8 9.1 5.3 42 6 40 165 9.9 0 10.1 9.3 07/11/2006 19:50:00 7.5 0.7 9.5 5.3 7.5 0.7 9.9 5.7 7.3 0.8 9.1 4.9 40 5 52 165 9.9 0 10.1 9.6 07/11/2006 20:00:00 6.5 0.9 9.1 4.6 6.5 0.9 9.1 4.2 6.3 1 8.4 3.8 43 8 41 165 9.9 0 10.6 9.6 07/11/2006 20:10:00 7.3 1 11.5 5.3 7.3 1 11.8 4.9 7.1 1 11.8 4.2 43 6 52 165 10 0.1 10.6 9.3 07/11/2006 20:20:00 6.9 0.6 8.4 4.9 6.9 0.7 8.8 4.9 6.5 0.8 8.4 4.6 45 6 36 165 9.9 0 10.1 9.6 07/11/2006 20:30:00 6.9 0.7 8.4 4.6 6.9 0.7 8.4 4.6 6.5 0.7 8 4.2 46 6 42 165 10 0.1 10.3 9.6 07/11/2006 20:40:00 6.8 0.8 8.4 4.6 6.9 0.8 8.4 4.2 6.4 1 8.4 3.4 47 6 35 165 10 0.1 10.6 9.6 07/11/2006 20:50:00 6.2 1 8.8 3.8 6.2 1 8.8 3.8 6.1 0.9 8 3.8 43 7 32 165 10 0.1 10.3 9.6 07/11/2006 21:00:00 7 0.8 9.5 4.9 7 0.9 9.5 4.9 6.8 0.8 8.8 4.6 41 5 36 165 10 0.1 10.3 9.6 07/11/2006 21:10:00 6.6 1 8.4 3.8 6.6 1 8.8 3.8 6.4 1 8.4 3.4 42 7 42 165 10 0 10.1 9.6 07/11/2006 21:20:00 6.3 0.9 8.4 4.2 6.3 0.9 8 3.8 6.1 0.9 8.4 4.2 41 7 42 165 10 0 10.1 9.6 07/11/2006 21:30:00 5.2 0.8 7.6 3.4 5.2 0.8 7.6 3.4 4.9 0.8 7.2 3 50 9 48 165 10 0 10.3 9.6 07/11/2006 21:40:00 5.2 0.8 7.2 3 5.2 0.8 7.2 3 5.2 0.8 7.6 3 48 8 46 165 9.9 0 10.1 9.3 07/11/2006 21:50:00 4.5 0.8 6.8 2.6 4.6 0.8 6.8 2.6 4.6 0.7 6.5 2.6 53 10 39 165 9.9 0 10.1 9.6 07/11/2006 22:00:00 4.8 0.9 6.8 2.6 4.8 1 7.2 2.6 4.8 0.9 6.8 2.6 51 10 44 165 9.9 0 10.3 9.6 07/11/2006 22:10:00 5.6 0.8 7.6 3.4 5.6 0.8 7.6 3 5.4 0.8 7.6 3.4 44 8 43 165 9.8 0 10.3 9.6 07/11/2006 22:20:00 6.5 0.8 8.4 4.6 6.4 0.8 8.4 4.2 6.4 0.8 8.4 4.2 41 6 37 165 9.9 0 10.3 9.6 07/11/2006 22:30:00 7.1 0.7 9.1 5.3 7.1 0.7 9.1 4.9 6.9 0.8 8.8 5.3 37 6 44 165 10 0 10.1 9.6 07/11/2006 22:40:00 7 0.6 8.4 5.3 7 0.6 8.4 4.6 6.9 0.8 8.4 4.2 38 5 36 165 10 0 10.3 9.6 07/11/2006 22:50:00 6.9 0.8 8.8 4.6 6.8 0.9 9.1 4.6 6.6 1 9.1 4.2 39 5 44 165 10.1 0.1 10.6 9.6 07/11/2006 23:00:00 6.4 1 8.8 4.2 6.3 1 8.8 4.2 6.1 1 8.4 4.2 37 6 35 165 10.1 0.2 10.3 9.6 07/11/2006 23:10:00 4.8 1.2 7.6 1.9 4.8 1.2 7.6 1.9 4.7 1.2 7.6 2.3 41 8 37 165 10.1 0.1 10.3 9.6 07/11/2006 23:20:00 4.7 0.7 6.8 2.3 4.6 0.7 6.5 2.3 4.7 0.6 6.5 3 35 11 21 165 10.1 0.1 10.3 9.6 07/11/2006 23:30:00 6.1 1.3 9.1 3.4 6 1.3 9.1 3 5.9 1.4 9.5 3 32 8 30 165 10.1 0.1 10.3 9.6 07/11/2006 23:40:00 6.7 1 8.8 4.2 6.5 1 9.1 3.8 6.7 1 9.1 4.2 28 9 26 165 10.1 0.1 10.3 9.6 07/11/2006 23:50:00 5.8 0.9 8.8 3.8 5.6 1.1 8.8 2.3 5.7 0.9 8.4 3.8 27 10 35 165 10.1 0.1 10.3 9.6 07/12/2006 00:00:00 6.1 1.1 8.8 3 5.7 1.1 8.4 3 6 1 8.8 3.4 21 8 20 165 10.1 0.1 10.3 9.6 07/12/2006 00:10:00 7.1 1.1 9.9 4.9 6.8 1.1 9.5 3.8 6.8 1.1 9.9 3.8 24 8 23 165 10.1 0.1 10.3 9.6 07/12/2006 00:20:00 7 1 8.8 4.2 6.9 1 8.8 4.2 6.8 0.9 9.1 4.2 27 7 31 165 10.1 0.1 10.3 9.6 07/12/2006 00:30:00 6.4 0.8 8.4 4.2 6.3 0.8 8.4 4.2 6.2 0.8 8 4.2 28 6 28 165 10.1 0.1 10.6 9.6 07/12/2006 00:40:00 6.8 0.7 8.8 4.9 6.7 0.8 8.8 4.2 6.6 0.9 8.8 4.2 25 7 19 165 10.1 0.2 10.6 9.6 07/12/2006 00:50:00 6.2 0.9 8.4 3.8 6 1 8.4 3.4 6.2 0.9 8.4 3.8 24 8 21 165 10.1 0.2 10.3 9.6 07/12/2006 01:00:00 6 0.8 8 4.2 5.6 0.9 8 2.6 5.9 0.7 8 3.8 23 9 23 165 10.1 0.2 10.9 9.6 07/12/2006 01:10:00 6.5 0.7 8.4 4.2 5.8 0.9 8.4 3 6.3 0.8 8.8 4.2 18 6 18 165 10.1 0.2 10.9 9.6 07/12/2006 01:20:00 5.7 0.7 7.2 3.8 5.5 0.7 7.2 3.8 5.6 0.7 7.2 3.4 24 7 22 165 10.1 0.2 10.3 9.6 07/12/2006 01:30:00 6.4 0.8 8 4.2 6.1 0.8 8 4.2 6.4 0.7 8 3.8 22 6 27 165 10.1 0.2 10.3 9.6 07/12/2006 01:40:00 6.2 0.9 8 3.4 5.9 0.9 8 3.4 6.1 0.9 8.4 3.4 23 7 15 165 10.1 0.2 10.9 9.6 07/12/2006 01:50:00 6.4 0.8 8.4 4.2 5.8 1 7.6 3 6.4 0.8 8.8 4.2 17 6 19 165 10.1 0.2 10.3 9.6 07/12/2006 02:00:00 6.9 1.1 9.9 4.6 5.9 1.1 9.5 2.3 6.7 1.1 10.3 3.8 13 8 15 165 10.1 0.2 10.6 9.6 07/12/2006 02:10:00 7.6 0.9 9.9 4.9 6.7 1.2 9.5 3.4 7.4 1 10.7 4.9 15 6 12 165 10.1 0.2 10.3 9.6 07/12/2006 02:20:00 7.6 0.6 9.1 6.1 6.6 1.1 8.8 3.8 7.4 0.6 9.5 5.3 15 6 16 165 10.1 0.2 10.3 9.6 07/12/2006 02:30:00 7.3 0.6 8.8 5.3 6.7 0.9 8.4 3.8 7.1 0.8 8.8 4.9 17 5 3 165 10.1 0.2 10.6 9.6 07/12/2006 02:40:00 7 0.6 8.4 4.9 6.4 0.8 8 3.8 6.9 0.8 9.1 4.9 18 5 25 165 10.1 0.2 10.3 9.6 07/12/2006 02:50:00 7 0.5 8.4 5.7 6.2 0.8 8 3.8 6.8 0.6 8.4 4.9 15 5 11 165 10.1 0.1 10.3 9.6 07/12/2006 03:00:00 6.8 0.5 8 5.3 5.4 1 7.2 3 6.5 0.6 8 4.6 12 5 10 165 10.1 0.1 10.3 9.6 07/12/2006 03:10:00 7.1 0.5 8.4 5.7 5.8 0.9 7.6 3.4 7 0.6 8.4 5.3 12 5 11 165 10.1 0.1 10.6 9.6 07/12/2006 03:20:00 6.9 0.6 8 4.9 5.6 1 7.6 3 6.6 0.7 8 4.6 12 5 11 165 10 0 10.6 9.3 07/12/2006 03:30:00 6.4 0.5 8 4.6 4.5 0.8 6.5 2.6 6.3 0.6 7.6 4.6 9 4 12 165 10 0 10.1 9.3 07/12/2006 03:40:00 5.8 0.5 7.2 4.6 3.6 0.7 6.1 1.9 5.6 0.5 7.2 4.2 5 5 10 165 9.8 0 10.3 9.3 07/12/2006 03:50:00 5.5 0.5 6.8 4.2 3.2 0.6 5.3 1.9 5.3 0.5 6.8 4.2 4 4 3 165 9.8 0 9.8 9.3 07/12/2006 04:00:00 4.4 0.6 6.1 3 2.6 0.8 5.3 1.5 4.4 0.6 6.1 3.4 1 6 12 165 9.8 0 9.8 9.6 07/12/2006 04:10:00 3.9 0.6 5.3 2.6 2.6 1 5.7 1.1 3.8 0.5 5.3 3 357 6 348 165 9.6 0 9.8 9.3 07/12/2006 04:20:00 4.1 0.6 5.3 2.3 3.4 1 5.3 0.7 4.1 0.5 5.3 2.6 353 9 4 165 9.6 0 9.8 9.6 07/12/2006 04:30:00 3.6 0.6 5.3 2.3 2.8 1 5.3 0.7 3.6 0.5 4.9 2.3 350 9 336 165 9.6 0 9.8 9.6 07/12/2006 04:40:00 3.1 0.5 4.2 1.9 2 0.7 3.8 0.7 3.3 0.5 4.6 2.3 357 9 4 165 9.6 0 10.1 9.3 07/12/2006 04:50:00 3.1 0.4 4.2 1.9 2.7 0.6 4.2 1.1 3.4 0.4 4.9 2.3 349 5 344 165 9.4 0 9.6 9.3 07/12/2006 05:00:00 3.6 0.4 4.6 2.3 3.4 0.7 4.6 1.1 3.8 0.4 4.6 3 346 5 340 165 9.4 0 9.6 9.3 07/12/2006 05:10:00 4 0.4 4.9 3.4 3.7 0.7 5.3 1.5 4.2 0.4 5.3 3.4 347 5 347 165 9.6 0 10.1 9.3 07/12/2006 05:20:00 3.9 0.5 5.3 2.6 3.8 0.6 5.3 1.9 4 0.5 5.3 2.6 344 7 343 165 9.4 0 9.6 9 07/12/2006 05:30:00 4.9 0.5 6.1 3.4 4.8 0.6 6.1 2.3 4.7 0.5 5.7 3.4 339 6 333 165 9.4 0 9.6 9.3 07/12/2006 05:40:00 5.3 0.5 6.5 3.4 5.1 0.6 6.5 2.6 5.1 0.5 6.5 3.8 338 7 344 165 9.6 0 9.8 9.3 07/12/2006 05:50:00 4.7 0.8 6.8 3 4.6 1 6.8 1.9 4.7 0.8 6.8 3.4 341 6 339 165 9.6 0 9.8 9.3 07/12/2006 06:00:00 4.1 0.6 6.1 3 4 0.6 5.7 3 4.1 0.6 5.7 2.6 338 8 336 165 9.6 0 10.3 9.6 07/12/2006 06:10:00 4.1 0.4 5.3 3 4.1 0.4 4.9 3 4.2 0.4 5.3 3.4 325 7 328 165 10 0 10.3 9.6 07/12/2006 06:20:00 4.6 0.6 6.1 3 4.3 0.9 6.1 1.5 4.8 0.5 6.5 3.8 344 9 333 165 10.1 0 10.3 9.8 07/12/2006 06:30:00 4.8 0.6 6.5 3.4 4.8 0.7 6.5 3.4 4.9 0.6 6.5 3.4 338 9 332 165 10 0.1 10.6 9.6 07/12/2006 06:40:00 4.2 0.7 6.1 2.6 4 0.8 6.1 2.3 4.4 0.7 6.5 3 338 11 335 165 10.2 0.2 10.6 9.6 07/12/2006 06:50:00 4.6 0.6 6.1 3.4 4.5 0.6 6.1 3 4.7 0.7 6.1 3 337 8 339 165 10.3 0.1 10.9 9.8 07/12/2006 07:00:00 5.1 0.7 6.8 3.4 5 0.8 6.8 2.3 5.1 0.7 7.2 3.4 338 8 336 165 11.5 0.4 12.2 10.3 07/12/2006 07:10:00 4.6 0.8 6.5 2.3 4.1 1.1 6.5 1.5 4.7 0.8 6.5 2.6 346 10 343 165 12.3 0.1 12.7 11.7 07/12/2006 07:20:00 4.2 0.8 6.1 2.6 3.9 1 6.1 1.5 4.3 0.8 5.7 2.3 340 9 346 165 12.7 0.2 13 12.5 07/12/2006 07:30:00 4.4 0.5 5.3 3 3.9 0.8 5.3 1.9 4.4 0.5 5.7 3 348 7 351 165 12.3 0.2 13.3 11.7 07/12/2006 07:40:00 4.2 0.5 5.3 3 3.2 1 5.3 1.5 4.2 0.5 5.3 2.6 350 9 356 165 12.7 0.1 13 11.9 07/12/2006 07:50:00 3.6 0.5 4.6 2.3 2.9 0.8 4.6 1.1 3.8 0.5 5.3 2.6 350 12 339 165 12.9 0.3 13.5 12.2 07/12/2006 08:00:00 3.7 0.4 4.6 2.3 2.8 0.7 4.2 1.1 4 0.4 4.9 3 11 5 3 165 12.8 0.4 13.5 12.2 07/12/2006 08:10:00 3.7 0.6 4.9 2.3 2.8 0.8 4.6 1.1 4 0.5 5.3 2.6 7 11 11 165 11.9 0.2 12.5 11.7 07/12/2006 08:20:00 3.7 0.8 5.7 1.9 3.6 0.8 5.7 1.5 3.7 0.8 5.7 1.5 326 11 334 165 12.9 0.5 13.5 11.7 07/12/2006 08:30:00 2.4 0.8 4.2 0.7 2.4 0.8 4.2 0.4 2.4 0.8 4.6 0.4 313 13 292 165 14.1 0.3 14.6 13 07/12/2006 08:40:00 2.3 0.8 3.8 0.4 2.1 0.9 3.8 0.4 2.2 0.8 3.8 0.4 331 19 309 165 14.6 0 14.9 14.4 07/12/2006 08:50:00 2.1 0.9 4.2 0.4 1.8 1 3.8 0.4 2.2 0.7 3.8 0.4 342 28 293 165 14.4 0.3 14.9 14.1 07/12/2006 09:00:00 2.9 0.7 4.6 1.1 2.8 0.8 4.6 0.7 2.7 0.6 4.2 1.5 316 19 314 165 13.3 0.4 14.4 12.7 07/12/2006 09:10:00 2.9 0.7 4.9 1.1 2.6 0.8 4.2 0.4 3 0.6 4.9 1.5 353 26 314 165 14.4 0.4 14.9 13 07/12/2006 09:20:00 2.3 0.8 4.6 0.4 2 0.7 3.8 0.4 2.1 0.7 4.2 0.4 354 24 331 165 15.2 0.3 15.7 14.9 07/12/2006 09:30:00 1.3 0.8 3.8 0.4 1.1 0.8 3.4 0.4 1.4 0.8 4.2 0.4 20 27 63 165 15 0.4 16 14.4 07/12/2006 09:40:00 1.5 0.8 3.8 0.4 1.3 0.8 3.4 0.4 1.4 0.7 3.4 0.4 7 38 21 165 15 0.4 15.7 14.4 07/12/2006 09:50:00 1.4 0.7 3.4 0.4 1.2 0.6 3 0.4 1.5 0.6 3 0.4 30 26 358 165 14.5 0 14.9 14.4 07/12/2006 10:00:00 1 0.8 3.4 0.4 0.9 0.8 3.4 0.4 1 0.7 3 0.4 9 69 309 165 14.6 0.3 15.2 14.1 07/12/2006 10:10:00 1.4 0.8 3 0.4 1 0.7 3.4 0.4 1.2 0.7 3.8 0.4 344 47 45 165 15.8 0.3 16.6 15.2 07/12/2006 10:20:00 2.4 0.8 4.6 0.7 2.2 0.9 4.2 0.4 1.9 0.8 3.8 0.4 314 21 336 165 16 0.2 16.8 15.7 07/12/2006 10:30:00 2.5 1.2 5.3 0.4 2.2 1.1 4.9 0.4 2.4 1.1 4.9 0.4 347 27 338 165 16.6 0.3 17.1 16 07/12/2006 10:40:00 1.7 0.8 3.8 0.4 1.4 0.7 3 0.4 1.4 0.8 3.4 0.4 347 27 351 165 17.3 0.1 17.4 16.8 07/12/2006 10:50:00 1.3 0.7 3.4 0.4 1.2 0.7 3 0.4 1 0.6 2.3 0.4 341 82 88 165 17.6 0.1 18 16.8 07/12/2006 11:00:00 1.9 0.6 3.4 0.4 1.9 0.7 3.8 0.4 1.7 0.7 3.4 0.4 294 38 329 165 17.3 0 17.4 17.1 07/12/2006 11:10:00 1.6 0.6 3.4 0.4 1.6 0.6 3.4 0.4 1.3 0.6 3 0.4 322 32 338 165 17.8 0.2 18.2 17.4 07/12/2006 11:20:00 1.9 1.2 5.7 0.4 2 1.2 6.1 0.4 1.9 1.3 7.2 0.4 279 86 319 165 17.8 0 18.2 17.7 07/12/2006 11:30:00 1.2 0.6 3 0.4 1.1 0.6 3 0.4 1 0.6 3 0.4 349 49 341 165 17.8 0 18 17.1 07/12/2006 11:40:00 1.5 0.6 3 0.4 1.4 0.6 2.6 0.4 1.2 0.6 2.6 0.4 356 45 68 165 18.1 0.2 18.5 17.4 07/12/2006 11:50:00 1.5 1 4.2 0.4 1.4 1 3.4 0.4 1.1 0.9 4.2 0.4 10 86 355 165 18.4 0 18.5 18.2 07/12/2006 12:00:00 2.2 0.8 4.2 0.4 1.9 0.8 3.4 0.4 1.6 0.8 3.8 0.4 353 39 356 165 18.7 0.3 19.1 18.2 07/12/2006 12:10:00 1.8 1 4.6 0.4 1.7 0.9 4.2 0.4 1.5 0.8 3.8 0.4 24 72 27 165 18.8 0 19.1 18.5 07/12/2006 12:20:00 1.9 0.8 4.6 0.4 1.9 0.8 4.2 0.4 1.6 0.8 4.6 0.4 38 66 39 165 18.1 0 18.5 18 07/12/2006 12:30:00 1.2 0.6 3.4 0.4 1.2 0.6 3.4 0.4 1.1 0.7 3 0.4 154 72 165 165 18.2 0 18.2 18 07/12/2006 12:40:00 1.6 0.8 3.8 0.4 1.7 0.8 3.8 0.4 1.7 0.7 3.8 0.4 99 53 161 165 18.5 0.1 18.8 18 07/12/2006 12:50:00 1.3 0.6 3 0.4 1.3 0.6 3 0.4 1.4 0.6 3 0.4 152 24 119 165 17.1 0.4 18 16.8 07/12/2006 13:00:00 1.9 0.6 3 0.7 1.9 0.6 3.4 0.7 2 0.6 3.4 0.4 146 14 146 165 16.6 0.2 16.8 16.3 07/12/2006 13:10:00 1.1 0.6 3 0.4 1.1 0.6 3 0.4 1.1 0.6 3 0.4 133 29 148 165 16.2 0 16.6 16 07/12/2006 13:20:00 1 0.6 3.4 0.4 1 0.6 3.4 0.4 0.8 0.5 2.6 0.4 139 66 284 165 16.7 0.1 16.8 16.3 07/12/2006 13:30:00 3.1 0.7 5.3 1.1 3.2 0.7 5.7 1.1 2.4 0.7 4.2 0.4 296 22 263 165 17.9 0.6 18.8 16.6 07/12/2006 13:40:00 3.6 1 6.1 1.5 3.7 1 6.5 1.5 2.9 1 5.3 0.4 303 13 308 165 19 0.1 19.1 18.5 07/12/2006 13:50:00 3.5 0.8 5.7 1.5 3.6 0.7 6.1 1.5 2.7 1 4.9 0.4 289 15 303 165 19.2 0 19.7 18.8 07/12/2006 14:00:00 2.3 1.3 5.7 0.4 2.3 1.4 6.1 0.4 1.4 1.2 5.3 0.4 314 94 246 165 19 0.2 19.7 18.5 07/12/2006 14:10:00 3.4 1.4 6.5 0.4 3.5 1.5 6.5 0.4 2.6 1.2 5.7 0.4 268 35 231 165 18.2 0 18.8 18 07/12/2006 14:20:00 4.1 1 6.8 0.4 4.2 1 6.5 0.7 3.3 1.1 6.1 0.4 287 14 293 165 19.6 0.4 20.5 18.8 07/12/2006 14:30:00 4.1 1.1 6.8 0.7 4.1 1.1 6.5 0.7 3.1 1.1 5.7 0.4 292 17 307 165 20.5 0.2 21.1 20.2 07/12/2006 14:40:00 5.2 0.9 8 2.6 5.2 0.9 7.6 2.6 4.2 1.1 7.2 1.1 289 9 289 165 20.8 0.1 21.1 20.5 07/12/2006 14:50:00 4.8 1 7.6 1.9 4.9 1 7.6 2.3 3.9 1 6.8 1.5 298 10 301 165 20.2 0 20.5 20 07/12/2006 15:00:00 5.3 0.6 7.2 3.4 5.4 0.6 7.2 3.4 4.4 0.7 6.8 3 295 8 312 165 20.8 0 21.1 20.2 07/12/2006 15:10:00 4.9 1 8 1.9 5 1 8 2.3 4.2 1 6.8 1.9 296 13 305 165 21 0.1 21.1 20.8 07/12/2006 15:20:00 5.2 1.2 8 3 5.2 1.1 7.6 3 4.6 1 8 1.9 298 12 297 165 20.9 0 21.1 20.8 07/12/2006 15:30:00 5.5 1 8 2.6 5.6 1 8 3.4 4.9 1.1 7.6 1.9 299 12 300 165 20.7 0.2 21.1 20.2 07/12/2006 15:40:00 4.7 1.5 7.6 1.5 4.7 1.5 7.6 1.9 4.2 1.3 7.6 1.1 301 15 291 165 20.7 0.2 21.1 20 07/12/2006 15:50:00 6.3 0.8 8.4 3.8 6.3 0.8 8 3.8 5.4 0.9 8.4 3.4 299 8 289 165 20.3 0.3 20.8 19.7 07/12/2006 16:00:00 5.6 1 8.4 3.8 5.8 1 8.8 3.8 4.9 1.1 8.4 2.6 305 12 319 165 20.1 0.3 20.8 19.4 07/12/2006 16:10:00 5.8 1.1 8 1.9 5.9 1 8 3.4 5 1 8 2.6 300 8 310 165 20.3 0.2 20.8 20 07/12/2006 16:20:00 6.5 1 9.1 4.2 6.5 0.9 8.8 4.2 5.5 1.1 8.4 3.4 297 8 291 165 20.2 0 20.8 20 07/12/2006 16:30:00 6.4 1.1 8.8 4.2 6.4 1.1 9.1 3.8 5.3 0.8 7.6 3.4 295 9 303 165 20 0 20.5 19.7 07/12/2006 16:40:00 6.5 1 8.4 4.2 6.7 0.9 8.4 4.6 5.3 0.9 8 3.4 302 6 307 165 20.3 0 20.8 20 07/12/2006 16:50:00 6.8 0.8 9.1 4.2 6.7 0.9 8.8 4.2 6.3 0.9 8.8 3.8 317 10 322 165 20.6 0.2 21.1 20.2 07/12/2006 17:00:00 6.5 1 9.1 4.2 6.6 1 8.8 4.2 5.9 1.2 8.8 3.4 309 8 324 165 20.8 0.1 21.1 20.5 07/12/2006 17:10:00 6.9 0.8 9.1 4.6 6.9 0.7 9.1 4.6 5.6 0.8 8 3.8 299 6 301 165 20.1 0.1 20.8 20 07/12/2006 17:20:00 6.9 0.7 8.8 5.3 6.8 0.7 8.8 4.9 5.5 0.8 8.8 3.8 299 7 293 165 20 0 20.2 19.7 07/12/2006 17:30:00 6.8 0.8 9.1 4.6 6.7 0.9 9.1 4.6 5.5 1 8.4 3 299 6 291 165 19.9 0 20.2 19.7 07/12/2006 17:40:00 6.1 0.6 7.6 4.6 6 0.6 8 4.2 5.2 0.7 6.8 3.8 302 6 304 165 20 0 20.2 19.7 07/12/2006 17:50:00 6.3 0.7 8.4 4.6 6.2 0.7 8 4.6 5.2 0.8 7.6 3.4 297 7 290 165 20 0 20.2 20 07/12/2006 18:00:00 6.5 0.8 8.8 4.6 6.4 0.8 8.4 4.9 5.9 0.9 8 3.8 310 8 307 165 20.2 0.1 20.8 20 07/12/2006 18:10:00 6.6 0.9 8.8 4.2 6.5 0.8 8.4 4.2 6.1 1.1 8.8 3.4 308 11 302 165 20.4 0 20.5 20.2 07/12/2006 18:20:00 6.4 0.8 8 4.6 6.5 0.7 8 4.6 5.5 0.8 7.6 3.4 308 8 290 165 20.4 0 20.8 20.2 07/12/2006 18:30:00 7.5 0.7 9.5 5.7 7.4 0.7 9.1 5.3 6.8 1.1 9.5 3.8 313 7 316 165 20.2 0 20.5 20 07/12/2006 18:40:00 7 0.7 8.8 5.3 6.9 0.7 8.8 4.9 6.5 1 8.4 3.8 314 8 309 165 20.1 0 20.5 20 07/12/2006 18:50:00 7.5 0.7 8.8 5.3 7.2 0.7 8.8 5.3 6.8 0.7 8.4 4.9 311 4 309 165 19.9 0 20.2 19.7 07/12/2006 19:00:00 7.6 0.5 8.8 6.5 7.4 0.5 8.8 6.1 6.9 0.6 8.4 5.3 312 4 308 165 19.7 0 20 19.7 07/12/2006 19:10:00 8 0.6 9.1 6.5 7.8 0.6 9.1 6.1 6.9 0.9 8.8 4.6 308 5 312 165 19.5 0 19.7 19.4 07/12/2006 19:20:00 6.3 0.6 8 4.6 6.1 0.6 7.6 4.2 5.7 1 7.6 3.4 309 7 314 165 19.6 0 19.7 19.4 07/12/2006 19:30:00 6.4 0.6 7.6 4.6 6.2 0.6 7.6 4.9 5.2 0.7 6.8 3.4 303 7 294 165 19.6 0 19.7 19.4 07/12/2006 19:40:00 6.8 0.4 7.6 5.7 6.7 0.4 7.6 5.3 5.3 0.6 6.8 3.8 299 6 295 165 19.4 0 19.7 19.4 07/12/2006 19:50:00 6.5 0.6 8 4.6 6.4 0.7 8 3.8 5.1 0.6 6.8 3.8 301 5 305 165 19.3 0 19.7 19.1 07/12/2006 20:00:00 7 0.8 8.8 4.9 6.9 0.8 8.4 4.9 5.8 0.7 7.6 3.8 305 6 302 165 19.2 0.1 19.4 18.8 07/12/2006 20:10:00 7.8 0.8 9.1 5.3 7.6 0.8 9.1 5.3 6.6 0.8 8.4 4.9 307 5 300 165 18.9 0 19.1 18.5 07/12/2006 20:20:00 8.8 0.7 10.3 6.8 8.7 0.8 10.3 6.5 7.1 0.9 9.9 4.6 307 4 307 165 18.5 0 18.8 18.5 07/12/2006 20:30:00 8.9 0.5 10.3 7.2 8.7 0.6 9.9 7.2 7.7 0.7 9.5 5.7 309 3 311 165 18.5 0 18.5 18.2 07/12/2006 20:40:00 8.8 0.6 9.9 7.2 8.7 0.6 9.9 6.8 7.4 0.7 9.1 5.3 307 4 308 165 18.1 0.1 18.5 17.7 07/12/2006 20:50:00 9.2 0.7 10.3 6.8 9.1 0.8 10.7 6.5 7.7 0.7 9.5 5.7 308 4 308 165 17.7 0.1 18 17.1 07/12/2006 21:00:00 9 0.8 11.1 6.5 8.8 0.8 11.1 6.1 7.7 0.9 9.9 5.3 309 4 311 165 17.3 0 17.7 16.8 07/12/2006 21:10:00 9.2 0.6 10.3 7.2 9.1 0.7 10.3 7.2 8 0.8 9.5 5.7 310 4 313 165 17.3 0 17.4 16.8 07/12/2006 21:20:00 9.4 0.6 10.7 7.2 9.3 0.7 10.7 7.2 7.8 0.8 9.9 5.7 307 4 310 165 16.8 0 17.1 16.8 07/12/2006 21:30:00 9.2 0.5 10.3 6.8 9.2 0.6 10.3 6.8 7.2 0.7 9.1 5.7 305 4 306 165 16.6 0 16.8 16.6 07/12/2006 21:40:00 9 0.7 10.7 7.2 9 0.8 10.7 6.8 6.7 0.6 8.4 4.9 303 4 297 165 16.5 0 16.8 16.6 07/12/2006 21:50:00 9 0.6 10.7 6.5 9 0.6 10.3 6.1 6.5 0.6 8 4.9 303 3 301 165 16.5 0 16.8 16.6 07/12/2006 22:00:00 9.6 0.6 11.5 7.2 9.6 0.6 11.1 7.2 6.7 0.7 8.4 4.9 302 3 300 165 16.7 0 16.8 16.6 07/12/2006 22:10:00 9.2 0.7 10.7 7.2 9.2 0.8 11.1 6.5 6.9 0.8 8.8 4.9 304 4 301 165 16.8 0 16.8 16.6 07/12/2006 22:20:00 9.2 1.1 13 6.5 9.2 1.1 12.6 6.5 7 0.9 11.1 4.9 303 5 298 165 16.8 0 17.1 16.8 07/12/2006 22:30:00 9.3 0.8 11.5 7.6 9.2 0.8 11.1 7.2 7 0.7 9.1 4.9 303 4 301 165 17 0 17.1 16.8 07/12/2006 22:40:00 9.2 0.8 11.1 6.5 9.1 0.8 10.7 6.5 6.7 0.9 9.9 4.6 300 5 287 165 17.1 0 17.4 16.8 07/12/2006 22:50:00 9.9 1 13 7.6 9.9 1 12.2 7.6 7.5 1.2 11.8 4.9 301 6 302 165 17.3 0.1 17.7 16.8 07/12/2006 23:00:00 9.4 0.9 11.8 6.8 9.3 0.9 11.5 6.5 7.1 1 9.5 4.9 303 6 287 165 17.5 0 17.7 17.4 07/12/2006 23:10:00 8.4 1.2 12.2 5.7 8.3 1.1 12.2 5.3 6.9 1 9.5 4.6 307 8 305 165 17.7 0 18.2 17.4 07/12/2006 23:20:00 8.1 1 10.3 5.3 8 1 10.3 5.3 6.4 1 9.1 3.8 302 7 297 165 17.5 0 18 17.4 07/12/2006 23:30:00 6.7 1.2 9.9 3.4 6.7 1.3 10.3 3.8 5.9 1 8.8 3.4 312 13 297 165 17.3 0.1 18 16.8 07/12/2006 23:40:00 7.7 1.2 10.3 4.2 7.6 1.1 10.3 4.6 6.3 1.1 9.1 3.4 306 10 311 165 17.5 0 17.7 17.1 07/12/2006 23:50:00 6.9 1.2 9.5 3.4 6.8 1.2 9.5 3.4 5.4 1 8 2.3 304 12 303 165 17.4 0.1 18 17.1 07/13/2006 00:00:00 7.8 1.2 10.7 4.2 7.8 1.1 10.7 4.2 6.1 1.2 8.8 2.3 301 11 301 165 17.4 0.1 17.7 16.8 07/13/2006 00:10:00 8.6 1.3 11.5 4.6 8.5 1.3 11.1 4.2 6.6 1.3 10.3 3.4 300 8 300 165 17.3 0.1 17.7 16.8 07/13/2006 00:20:00 8.6 1.1 11.8 6.1 8.5 1.1 11.8 6.1 6.6 1.2 11.1 3.8 300 8 315 165 17.6 0.2 18.2 17.1 07/13/2006 00:30:00 9.6 1.2 12.6 6.1 9.5 1.2 12.2 6.1 7.3 1.3 10.7 4.6 299 7 305 165 17.6 0.1 18 17.1 07/13/2006 00:40:00 9.6 1.4 13 6.5 9.4 1.3 12.6 6.1 7.5 1.3 11.8 4.9 301 8 298 165 17.7 0.2 18 17.1 07/13/2006 00:50:00 9.7 1.3 13 5.3 9.5 1.3 13 4.9 7.3 1.2 10.7 4.2 299 6 302 165 17.7 0 18 17.4 07/13/2006 01:00:00 10.2 1.4 12.6 5.7 10.1 1.3 13 6.1 7.7 1.3 11.5 4.6 300 6 297 165 17.9 0 18.2 17.4 07/13/2006 01:10:00 9.5 1.2 14.1 6.1 9.3 1.2 13.3 5.7 7.3 1.2 11.5 4.6 299 7 303 165 17.9 0.1 18.2 17.4 07/13/2006 01:20:00 8.7 1.5 11.8 3.4 8.6 1.4 11.5 3.4 6.6 1.5 9.9 1.1 299 8 307 165 17.8 0.2 18.5 17.4 07/13/2006 01:30:00 8.8 1.2 11.5 5.7 8.7 1.1 11.1 5.7 6.8 1.3 10.7 3.8 296 8 290 165 17.9 0.1 18.2 17.4 07/13/2006 01:40:00 8.5 1.3 11.8 4.9 8.4 1.2 11.5 4.9 6.4 1.3 9.5 2.3 294 9 308 165 17.8 0.2 18.2 17.4 07/13/2006 01:50:00 7.3 1.2 11.1 3.8 7.2 1.2 10.7 3.8 5.3 1.3 8.8 1.5 296 10 290 165 17.5 0.1 18 16.8 07/13/2006 02:00:00 8 1.2 11.1 4.6 7.9 1.2 11.1 4.6 6.1 1.1 9.1 3.4 300 8 304 165 17.3 0.1 17.7 16.8 07/13/2006 02:10:00 8.6 1.3 11.5 4.6 8.4 1.3 11.1 4.2 6.7 1.1 9.9 3.8 303 8 298 165 17.4 0.1 17.7 16.8 07/13/2006 02:20:00 9.1 1.2 12.2 6.1 8.9 1.1 11.5 5.7 7.2 1.2 9.9 4.2 305 7 302 165 17.3 0.2 18.2 16.8 07/13/2006 02:30:00 9.7 1 11.8 6.5 9.5 1 11.8 6.5 7.6 1.1 10.7 4.6 305 6 308 165 17.6 0.1 18.2 16.8 07/13/2006 02:40:00 9.2 1.3 12.2 4.9 9 1.3 12.2 4.9 7.1 1.1 9.5 3.4 303 6 292 165 17.7 0.2 18 17.1 07/13/2006 02:50:00 8.2 1.3 11.1 5.3 8.1 1.2 11.1 5.3 6.4 1.3 10.7 3.8 304 8 312 165 17.8 0.1 18 17.4 07/13/2006 03:00:00 8.3 1.2 11.5 5.7 8.2 1.2 11.5 5.3 6.6 1.2 9.5 3.8 303 8 300 165 17.8 0.1 18.2 17.4 07/13/2006 03:10:00 8.7 1.1 11.5 5.7 8.6 1.2 11.5 5.7 6.6 1 9.5 3.8 299 7 305 165 18.1 0.1 18.2 17.7 07/13/2006 03:20:00 8.9 1 11.1 6.8 8.8 1 11.1 6.1 6.9 1.1 10.3 4.2 302 8 305 165 18.2 0 18.8 17.7 07/13/2006 03:30:00 8.4 1 11.5 6.1 8.3 1.1 11.1 5.7 6.5 1.1 11.8 3.8 299 7 308 165 18 0.1 18.2 17.4 07/13/2006 03:40:00 8.6 1.4 12.6 6.1 8.6 1.4 12.6 6.1 6.8 1.3 11.1 4.6 300 6 293 165 17.8 0.2 18.2 17.4 07/13/2006 03:50:00 8.9 1 12.2 6.5 8.9 1.1 11.8 6.8 7.1 1.2 11.1 4.9 296 7 295 165 17.8 0.1 18.2 17.4 07/13/2006 04:00:00 8.7 1.2 12.2 5.7 8.6 1.2 12.2 5.3 6.7 0.9 9.5 4.6 297 6 300 165 17.9 0.1 18.2 17.4 07/13/2006 04:10:00 8 1.2 11.5 4.9 8 1.2 11.1 5.3 7.2 1.3 11.1 4.2 290 6 293 165 17.9 0 18.2 17.4 07/13/2006 04:20:00 9.3 1.1 12.6 6.5 9.4 1.2 12.6 6.1 8.3 1.3 11.8 4.9 291 6 293 165 17.9 0 18.5 17.4 07/13/2006 04:30:00 9.8 1.1 13 6.8 9.9 1.1 12.6 6.5 8.7 1.2 11.5 4.9 290 4 293 165 17.8 0 18.2 17.4 07/13/2006 04:40:00 10.3 1.1 13 8 10.4 1.1 13.3 8 9 1.5 12.6 4.9 290 4 286 165 17.7 0.1 18 17.4 07/13/2006 04:50:00 9.9 1.1 12.6 6.8 10 1.1 12.6 6.8 8 1.3 11.8 4.6 293 4 288 165 17.6 0 18.2 17.4 07/13/2006 05:00:00 9.2 0.8 12.2 7.2 9.3 0.8 12.6 7.2 7 1 11.5 4.9 296 4 287 165 17.5 0 18 17.1 07/13/2006 05:10:00 9.4 0.6 11.1 7.6 9.5 0.7 11.1 7.2 6.7 0.8 9.9 5.3 298 4 297 165 17.5 0 18 17.1 07/13/2006 05:20:00 8.2 0.8 10.7 5.7 8.2 0.8 10.7 6.1 6.3 0.7 9.1 4.6 298 6 295 165 17.8 0.1 18.2 17.4 07/13/2006 05:30:00 8.4 1 11.1 5.7 8.5 1 11.1 5.7 6.5 1.2 9.9 4.2 293 5 294 165 18 0 18.2 17.7 07/13/2006 05:40:00 8.9 1 11.8 5.7 9 1 12.2 5.7 7 1.1 9.5 3.8 293 5 294 165 18 0 18.2 17.7 07/13/2006 05:50:00 8.6 0.8 10.3 6.1 8.6 0.9 10.7 6.1 6.4 0.9 8.8 4.6 297 5 301 165 18.2 0 18.5 18 07/13/2006 06:00:00 8.2 1.1 11.1 5.3 8.2 1.2 11.1 5.3 6.3 1 9.1 3.8 297 7 293 165 18.4 0 18.5 18.2 07/13/2006 06:10:00 8.3 1 10.7 4.9 8.3 1.1 10.7 4.6 6.2 1.1 9.1 4.2 295 7 286 165 18.5 0 18.5 18.2 07/13/2006 06:20:00 7.7 1.1 10.3 4.9 7.7 1.1 10.3 4.6 5.8 0.9 8.4 3.8 298 7 294 165 18.5 0 18.8 18.2 07/13/2006 06:30:00 7.5 1 9.9 4.2 7.5 1 9.9 4.2 5.8 1 9.1 3.4 298 8 290 165 18.7 0 19.1 18.2 07/13/2006 06:40:00 6.7 0.8 8.4 4.2 6.7 0.8 8.4 4.2 5.1 0.9 7.6 3 296 6 295 165 19.3 0.2 19.7 19.1 07/13/2006 06:50:00 5.7 1 8.4 3.4 5.8 1 8.4 3.4 4.6 0.7 7.2 2.3 301 8 300 165 19.5 0.1 19.7 18.8 07/13/2006 07:00:00 6.7 0.9 8.8 4.9 6.8 0.8 8.8 4.6 5 0.8 6.8 3 300 5 299 165 19.1 0.1 19.7 19.1 07/13/2006 07:10:00 6.9 1 9.1 4.2 7 0.9 8.8 4.2 5.3 0.8 8 3 300 5 300 165 19.3 0 19.7 19.1 07/13/2006 07:20:00 6.5 0.6 8 4.9 6.5 0.7 8 4.9 4.9 0.6 6.8 3.4 301 5 297 165 19.5 0.1 19.7 19.1 07/13/2006 07:30:00 7 0.8 8.8 4.6 7 0.7 8.8 4.6 5.5 0.7 7.2 3.8 301 7 306 165 19.5 0 19.7 19.4 07/13/2006 07:40:00 7.4 0.8 9.5 5.7 7.2 0.8 9.5 4.9 5.9 0.9 8 3.4 304 6 302 165 19.5 0 19.7 19.4 07/13/2006 07:50:00 6.8 0.8 9.1 4.6 6.6 0.8 8.8 4.2 5.8 0.7 7.6 3.4 309 6 307 165 19.5 0 20 19.4 07/13/2006 08:00:00 5.3 1 8 2.6 5.4 0.8 7.6 3 4.7 0.9 7.2 2.3 311 11 311 165 20.2 0.1 20.5 20 07/13/2006 08:10:00 6.3 1.2 8.8 3 6.3 1.1 8.8 3 5.1 1 7.2 2.6 305 8 305 165 20.5 0 20.8 20.5 07/13/2006 08:20:00 7.4 0.8 9.1 4.9 7.3 0.8 8.8 4.9 5.7 0.8 7.6 3.4 302 5 300 165 20.5 0 20.8 20.5 07/13/2006 08:30:00 7.1 0.9 9.1 4.2 6.9 0.9 8.8 4.6 5.7 1.1 8.8 2.6 302 6 299 165 20.9 0.1 21.1 20.5 07/13/2006 08:40:00 7.4 1.1 9.5 3.8 7.3 1 9.5 3.8 5.9 1 8 2.6 304 6 299 165 21.2 0 21.4 21.1 07/13/2006 08:50:00 8.3 1 10.3 5.7 8.1 1 10.3 4.9 7.1 0.9 9.5 4.6 309 5 304 165 21 0 21.1 20.8 07/13/2006 09:00:00 8.7 0.8 10.7 4.9 8.5 0.9 10.3 4.9 7.5 0.8 9.9 4.6 310 4 308 165 21 0 21.1 20.8 07/13/2006 09:10:00 8.9 0.6 10.3 6.8 8.7 0.7 10.3 6.1 7.8 0.8 9.9 5.7 311 5 306 165 21 0 21.1 20.8 07/13/2006 09:20:00 9.1 0.8 10.3 6.5 9 0.8 10.3 6.5 7.7 1 9.5 5.3 309 5 309 165 21 0 21.1 20.8 07/13/2006 09:30:00 9 1 11.1 5.3 8.8 1 11.1 5.3 8.3 1.2 11.1 4.9 313 7 309 165 21 0 21.1 20.8 07/13/2006 09:40:00 8.9 0.8 10.7 6.5 8.8 0.8 10.7 6.5 7.4 0.9 10.3 4.6 307 5 313 165 21 0 21.1 20.8 07/13/2006 09:50:00 8.4 0.9 10.3 5.7 8.2 1 10.3 5.3 6.8 0.9 8.8 4.9 306 6 307 165 21.2 0 21.4 21.1 07/13/2006 10:00:00 8.8 0.6 10.3 7.2 8.7 0.7 10.3 6.8 6.9 0.8 9.1 4.9 306 4 294 165 21.1 0.1 21.1 20.8 07/13/2006 10:10:00 9.3 0.8 12.2 6.8 9.2 0.9 11.5 6.8 7.2 0.8 10.7 5.3 305 4 293 165 21.3 0 21.4 21.1 07/13/2006 10:20:00 9 0.7 10.7 6.5 8.9 0.8 10.7 6.5 7.6 1 9.9 5.3 308 6 308 165 21.5 0 21.7 21.1 07/13/2006 10:30:00 8.6 0.8 10.7 6.1 8.4 0.8 10.3 6.1 7.8 1 10.3 5.3 313 8 305 165 21.8 0.1 22.3 21.1 07/13/2006 10:40:00 8.7 0.8 11.1 6.5 8.6 0.8 10.7 6.5 7.8 0.9 9.9 4.6 311 6 314 165 21.8 0.1 22.6 21.4 07/13/2006 10:50:00 7.8 0.7 9.9 5.7 7.5 0.7 9.5 5.7 7.5 0.8 10.7 5.3 317 5 316 165 22.2 0 22.9 22 07/13/2006 11:00:00 6.3 0.6 8 4.9 6.1 0.6 7.6 4.9 5.9 0.8 7.6 3.4 312 6 297 165 22.5 0.1 22.9 22 07/13/2006 11:10:00 4.9 0.6 6.1 3.8 4.9 0.6 6.5 3.4 4.2 0.9 6.8 2.6 307 8 313 165 23.1 0 23.5 22.6 07/13/2006 11:20:00 4.6 0.6 6.5 3 4.6 0.6 6.8 3 3.7 0.7 6.1 1.9 301 6 300 165 23.8 0.1 24.1 23.5 07/13/2006 11:30:00 5 0.8 7.2 3.4 5.1 0.7 6.8 3.4 4.2 0.8 6.5 1.9 300 7 294 165 23.1 0.1 23.5 22.6 07/13/2006 11:40:00 4.6 0.9 6.1 1.5 4.7 0.9 6.1 1.5 3.9 1 6.5 1.1 291 11 292 165 22.9 0.2 23.5 22.6 07/13/2006 11:50:00 4.2 0.7 6.1 2.3 4.2 0.7 6.5 1.9 3.3 0.7 6.1 1.1 301 8 303 165 23.5 0.5 24.1 22.6 07/13/2006 12:00:00 2.2 1.3 5.3 0.4 2.2 1.3 4.9 0.4 1.5 1 4.2 0.4 289 49 297 165 23.7 0.3 24.1 22.6 07/13/2006 12:10:00 2.2 0.8 4.9 0.4 2.3 0.7 4.9 0.4 1.7 0.7 3 0.4 161 76 302 165 22.1 0.3 22.9 21.4 07/13/2006 12:20:00 2.5 0.8 4.9 0.4 2.6 0.8 4.6 0.7 2.5 1 4.9 0.4 117 27 138 165 21.4 0 21.7 21.1 07/13/2006 12:30:00 2.7 0.6 4.2 1.1 2.7 0.6 4.6 1.1 2.8 0.6 4.6 1.5 148 13 143 165 20.6 0.1 21.1 20.2 07/13/2006 12:40:00 2.8 0.5 4.2 1.5 2.8 0.5 4.6 1.5 2.9 0.5 4.2 1.9 162 9 170 165 20.2 0 20.8 20 07/13/2006 12:50:00 2.7 0.6 4.2 1.5 2.8 0.6 4.2 1.5 2.9 0.6 4.2 1.5 154 9 172 165 20.7 0.2 21.1 20.2 07/13/2006 13:00:00 2.9 0.4 4.2 2.3 3 0.4 4.2 2.3 3.1 0.4 4.2 1.9 147 9 135 165 20.8 0.3 21.4 20.2 07/13/2006 13:10:00 3.3 0.4 4.9 1.9 3.3 0.5 4.9 1.9 3.5 0.5 5.3 2.6 152 7 139 165 20.5 0 20.8 20.2 07/13/2006 13:20:00 3.5 0.4 4.9 2.3 3.5 0.4 4.9 2.3 3.4 0.5 4.9 2.3 149 9 165 165 20.5 0.2 20.8 20 07/13/2006 13:30:00 3.7 0.4 4.9 2.6 3.7 0.4 4.9 2.6 3.7 0.4 4.9 2.6 151 8 159 165 20 0 20.5 19.7 07/13/2006 13:40:00 3.5 0.4 4.6 2.3 3.5 0.4 4.6 2.3 3.5 0.4 4.6 2.6 158 8 162 165 19.1 0.1 19.7 18.8 07/13/2006 13:50:00 3.3 0.3 3.8 1.9 3.2 0.3 3.8 1.9 3 0.3 3.8 2.3 148 8 147 165 19 0.2 19.7 18.5 07/13/2006 14:00:00 3.9 0.4 4.9 3 3.8 0.4 4.9 2.6 3.6 0.3 4.6 3 139 6 138 165 19.3 0.3 20 18.8 07/13/2006 14:10:00 3.8 0.5 4.9 2.3 3.7 0.5 4.9 2.6 3.6 0.5 4.9 2.3 134 9 131 165 19 0 19.7 18.5 07/13/2006 14:20:00 3.9 0.5 5.3 2.6 3.9 0.6 5.7 2.6 3.8 0.6 5.3 2.3 130 7 135 165 18.8 0 19.1 18.5 07/13/2006 14:30:00 4.8 0.7 6.5 3 4.8 0.7 6.5 3 4.6 0.8 6.1 2.6 132 8 141 165 18.5 0.1 18.8 18 07/13/2006 14:40:00 4.4 0.7 6.1 3 4.4 0.7 6.1 3 4.2 0.5 5.7 3 131 8 133 165 18.1 0 18.2 18 07/13/2006 14:50:00 3.8 0.5 5.3 2.3 3.8 0.5 4.9 2.3 3.7 0.5 5.3 1.9 126 6 128 165 18 0 18.2 18 07/13/2006 15:00:00 4 0.7 5.3 2.3 4.1 0.7 5.7 2.3 3.8 0.7 5.3 2.3 121 7 130 165 18.2 0 18.2 18 07/13/2006 15:10:00 3.5 0.5 4.9 2.3 3.5 0.5 4.9 2.6 3.5 0.5 4.6 2.6 122 7 126 165 18.5 0.2 19.4 18.2 07/13/2006 15:20:00 3.2 0.4 4.2 1.5 3.2 0.4 4.2 1.9 3.1 0.4 4.2 2.3 131 9 119 165 19.7 0.1 20.2 19.1 07/13/2006 15:30:00 2.8 0.5 4.2 1.5 2.8 0.5 4.2 1.5 2.9 0.5 4.2 1.5 133 10 144 165 20.5 0 21.1 20.2 07/13/2006 15:40:00 2.8 0.5 3.8 1.5 2.7 0.5 3.8 1.1 2.8 0.6 4.6 1.1 130 9 125 165 20.4 0 20.8 20.2 07/13/2006 15:50:00 2 0.4 3 1.1 1.9 0.4 3 0.7 1.9 0.4 3.4 1.1 127 12 147 165 19.6 0.2 20.2 19.1 07/13/2006 16:00:00 2.3 0.2 3 1.9 2.3 0.2 3 1.5 2.2 0.3 3 1.5 123 5 118 165 19 0 19.4 18.8 07/13/2006 16:10:00 1.9 0.4 2.6 0.7 1.9 0.4 2.6 0.7 1.9 0.4 2.6 0.7 125 8 124 165 19.6 0.5 20.8 18.8 07/13/2006 16:20:00 1.9 0.5 3.4 0.7 1.9 0.5 3.4 0.7 1.9 0.6 3.4 0.7 139 15 143 165 21.3 0.3 21.7 20.8 07/13/2006 16:30:00 1.9 0.4 3 0.7 1.8 0.5 3 0.4 2 0.4 3 1.1 129 13 116 165 21.3 0 21.7 21.1 07/13/2006 16:40:00 2.6 0.3 3.4 1.9 2.6 0.3 3.4 1.5 2.6 0.4 3.8 1.5 123 5 127 165 20.8 0.3 21.1 20.2 07/13/2006 16:50:00 3 0.3 3.8 1.9 3 0.3 3.8 2.3 2.9 0.4 4.2 2.3 125 6 123 165 20.7 0.1 21.1 20.5 07/13/2006 17:00:00 3 0.3 3.4 2.3 3 0.3 3.8 2.3 2.8 0.4 3.8 1.5 124 6 111 165 20.7 0 20.8 20.5 07/13/2006 17:10:00 2.7 0.3 3.4 1.9 2.7 0.3 3.4 1.9 2.5 0.4 3.8 1.5 116 7 105 165 20.8 0 21.1 20.8 07/13/2006 17:20:00 2.5 0.3 3.4 1.9 2.5 0.3 3.4 1.9 2.4 0.3 3 1.5 113 5 111 165 20 0.5 21.1 19.4 07/13/2006 17:30:00 1.5 0.4 2.6 0.7 1.6 0.4 2.6 0.7 1.3 0.4 2.6 0.4 105 4 110 165 19.7 0.2 20.2 19.4 07/13/2006 17:40:00 0.9 0.4 1.9 0.4 0.9 0.4 1.9 0.4 0.7 0.4 1.9 0.4 110 6 104 165 20.5 0.2 21.1 20.2 07/13/2006 17:50:00 1 0.4 1.9 0.4 1 0.4 1.9 0.4 0.9 0.4 1.9 0.4 120 15 94 165 21.2 0 21.4 21.1 07/13/2006 18:00:00 2 0.9 4.6 0.4 1.7 0.8 4.6 0.4 1.8 0.8 3.8 0.4 21 56 349 165 21.3 0.3 21.7 20.5 07/13/2006 18:10:00 4.3 0.7 5.7 2.3 4 0.9 5.7 1.9 4.1 0.8 6.1 1.5 21 11 25 165 20.1 0.3 20.5 19.7 07/13/2006 18:20:00 3.7 0.8 5.7 1.9 3.3 0.8 5.3 1.5 3.4 0.7 5.7 1.5 13 15 7 165 19.2 0.1 19.7 18.8 07/13/2006 18:30:00 3.8 0.5 5.3 2.3 3.3 0.7 5.3 1.1 3.4 0.5 4.9 1.9 9 13 339 165 18.6 0 18.8 18.2 07/13/2006 18:40:00 3.9 0.6 5.3 2.6 3.3 0.8 5.3 1.9 3.7 0.6 5.7 2.6 6 12 11 165 18 0.1 18.5 17.7 07/13/2006 18:50:00 4.3 0.5 5.7 2.6 3.7 0.7 5.3 1.9 3.9 0.6 5.7 2.6 11 13 19 165 17.8 0 18.2 17.4 07/13/2006 19:00:00 3.8 0.6 5.7 1.9 3.1 0.8 5.3 1.5 3.6 0.5 4.9 2.3 11 13 18 165 18.3 0 18.5 18 07/13/2006 19:10:00 4.6 0.5 5.7 3 4.2 0.6 5.7 2.3 4.2 0.5 5.7 2.6 20 7 29 165 18 0.1 18.2 17.7 07/13/2006 19:20:00 4 0.5 4.9 2.6 3.4 0.6 4.9 1.9 3.9 0.5 4.9 2.6 12 8 5 165 17.9 0.3 18.2 17.1 07/13/2006 19:30:00 4.4 0.4 5.3 3 3.9 0.6 4.9 2.3 4.3 0.6 5.3 2.6 18 6 19 165 16.5 0.2 17.1 16.3 07/13/2006 19:40:00 3.4 0.3 4.2 2.3 2.9 0.5 3.8 1.5 3.3 0.4 4.2 1.9 13 7 357 165 16.9 0 17.1 16.6 07/13/2006 19:50:00 3.3 0.2 4.2 2.6 2.7 0.6 3.8 1.5 3.3 0.3 3.8 2.6 356 11 353 165 15.7 0.4 16.8 15.2 07/13/2006 20:00:00 3.2 0.2 3.8 2.6 3.2 0.4 3.8 1.9 3.1 0.2 3.4 2.6 339 7 342 165 15.1 0 16 14.9 07/13/2006 20:10:00 2.9 0.2 3.4 2.3 2.9 0.2 3.4 2.3 2.7 0.2 3 1.9 333 4 333 165 15.2 0.1 15.7 14.9 07/13/2006 20:20:00 3 0.3 3.8 2.3 2.6 0.7 4.2 1.1 3 0.3 3.8 2.3 348 7 341 165 15.1 0.1 15.7 14.9 07/13/2006 20:30:00 2.9 0.3 3.8 1.9 2.6 0.6 3.8 1.1 3 0.3 3.8 1.9 348 5 347 165 14.9 0 15.2 14.6 07/13/2006 20:40:00 2.8 0.4 3.4 1.9 1.9 0.6 3.4 0.7 2.8 0.4 3.4 1.9 356 5 3 165 14.9 0 15.2 14.6 07/13/2006 20:50:00 1.4 0.4 2.6 0.7 1.2 0.4 2.6 0.4 1.5 0.5 2.6 0.4 10 15 7 165 15.1 0.2 15.7 14.6 07/13/2006 21:00:00 1.2 0.7 2.6 0.4 1.2 0.7 2.6 0.4 1.4 0.7 2.6 0.4 19 5 25 165 15 0.1 15.7 14.6 07/13/2006 21:10:00 2.1 0.3 2.6 1.1 1.9 0.4 2.6 1.1 2.2 0.3 3 1.1 18 13 22 165 14.1 0.3 14.9 13.5 07/13/2006 21:20:00 1.9 0.5 3.4 1.1 1.7 0.6 3 0.4 2.3 0.5 3.8 1.1 14 15 20 165 13.9 0.1 14.6 13.5 07/13/2006 21:30:00 2.8 0.3 3.8 2.3 2.7 0.3 3.8 1.9 3.2 0.4 4.2 2.6 28 8 42 165 14 0.1 14.4 13.5 07/13/2006 21:40:00 2.9 0.6 4.2 1.5 2.9 0.6 4.2 1.9 3.4 0.8 4.6 1.9 30 5 31 165 13.5 0 13.8 13.5 07/13/2006 21:50:00 3 0.4 3.8 1.9 2.7 0.7 4.2 0.7 3.3 0.6 4.6 1.9 23 12 34 165 13.6 0.2 14.1 13 07/13/2006 22:00:00 4.2 0.4 5.3 3.4 4.2 0.4 5.3 3.4 4.7 0.4 6.1 4.2 32 4 40 165 13.5 0.1 13.5 13 07/13/2006 22:10:00 5 0.2 5.7 4.2 5.1 0.3 5.7 4.2 5.3 0.3 6.1 4.6 35 2 37 165 13.3 0 13.5 13 07/13/2006 22:20:00 4.6 0.2 5.3 3.8 4.7 0.2 5.3 3.8 4.6 0.3 5.3 3.8 35 2 33 165 13.1 0 13.3 12.5 07/13/2006 22:30:00 4.4 0.2 4.9 3.8 4.4 0.2 4.9 3.8 4.5 0.3 4.9 3.8 36 2 37 165 13.1 0 13.3 12.5 07/13/2006 22:40:00 4.1 0.4 4.9 3 4.1 0.4 4.9 3 4.1 0.4 4.9 3 27 3 28 165 12.9 0.1 13.3 12.5 07/13/2006 22:50:00 3.7 0.3 4.6 3 3.6 0.4 4.2 2.3 3.7 0.3 4.2 3 25 4 18 165 12.8 0 13 12.2 07/13/2006 23:00:00 3.7 0.2 4.2 3 3.7 0.3 4.2 3 3.8 0.4 4.6 3 34 4 32 165 12.8 0 13 12.7 07/13/2006 23:10:00 3.8 0.3 4.6 3 3.8 0.3 4.6 3 4.1 0.3 4.6 3.4 34 2 33 165 12.9 0 13 12.7 07/13/2006 23:20:00 2.9 0.4 3.8 1.9 2.8 0.5 3.8 1.5 3.2 0.5 4.2 2.3 24 8 19 165 12.6 0 12.7 12.5 07/13/2006 23:30:00 1.6 0.6 3 0.7 1.5 0.7 3 0.4 1.9 0.4 2.6 0.7 24 6 28 165 12.6 0 13 12.5 07/13/2006 23:40:00 2.3 0.3 3 1.5 2.2 0.3 3 1.5 2.4 0.3 3.4 1.9 30 7 25 165 12.8 0 13 12.5 07/13/2006 23:50:00 2.7 0.4 3.4 1.9 2.7 0.4 3.4 1.9 2.9 0.4 3.8 2.3 32 4 26 165 12.7 0 13 12.5 07/14/2006 00:00:00 2.1 0.2 2.6 1.5 2.1 0.3 2.6 1.5 2.2 0.3 2.6 1.9 27 4 36 165 12.7 0 13 12.5 07/14/2006 00:10:00 1.7 0.4 2.3 0.7 1.7 0.4 2.3 0.4 1.8 0.4 2.6 0.7 39 10 29 165 12.7 0 13 12.5 07/14/2006 00:20:00 1.5 0.6 3 0.4 1.5 0.6 3 0.4 1.7 0.7 3.4 0.4 81 23 68 165 12.9 0.1 13 12.7 07/14/2006 00:30:00 2.4 0.6 3.8 0.4 2.5 0.6 3.8 0.7 2.5 0.6 3.8 0.7 68 12 66 165 13.1 0 13.3 12.7 07/14/2006 00:40:00 2.2 0.7 3.8 0.7 2.2 0.8 3.8 0.7 2 0.8 3.8 0.7 117 20 89 165 12.9 0.1 13 12.5 07/14/2006 00:50:00 1.1 0.3 1.9 0.4 1.1 0.3 1.9 0.4 1 0.3 1.9 0.4 133 14 147 165 12.9 0 13 12.5 07/14/2006 01:00:00 0.5 0.2 1.1 0.4 0.5 0.2 1.1 0.4 0.4 0.1 1.1 0.4 141 11 128 165 12.8 0 13 12.5 07/14/2006 01:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 151 0 165 165 12.7 0 12.7 12.7 07/14/2006 01:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 151 0 165 165 12.7 0 12.7 12.5 07/14/2006 01:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0.2 1.1 0.4 157 32 165 165 12.8 0 13 12.7 07/14/2006 01:40:00 0.8 0.4 1.5 0.4 0.7 0.5 1.9 0.4 0.9 0.4 1.9 0.4 314 11 307 165 12.7 0 12.7 12.5 07/14/2006 01:50:00 0.6 0.3 1.1 0.4 0.6 0.3 1.5 0.4 0.9 0.4 1.5 0.4 289 8 296 165 12.9 0.1 13.3 12.7 07/14/2006 02:00:00 1.8 0.9 3.8 0.4 1.9 0.9 3.4 0.4 2.3 0.8 3.8 1.1 272 9 267 165 12.7 0.3 13.3 12.2 07/14/2006 02:10:00 3.3 0.5 4.6 2.3 3.4 0.5 4.6 2.3 3 0.6 4.2 1.5 289 6 291 165 12.1 0 12.5 11.9 07/14/2006 02:20:00 2.9 0.8 4.6 0.7 3 0.8 4.6 0.7 2.3 0.7 3.8 0.4 294 6 296 165 11.9 0.1 12.2 11.7 07/14/2006 02:30:00 3.1 0.6 4.6 1.5 3.2 0.6 4.6 1.9 2.6 0.5 3.8 1.5 300 7 301 165 11.9 0 11.9 11.7 07/14/2006 02:40:00 2.6 0.4 3.8 1.5 2.7 0.4 3.8 1.9 2.7 0.6 3.8 1.5 291 7 286 165 11.7 0.1 12.2 11.4 07/14/2006 02:50:00 2.1 0.5 3.8 1.1 2.3 0.5 3.8 1.1 2.6 0.6 4.2 1.5 280 5 278 165 12.1 0 12.2 11.9 07/14/2006 03:00:00 2 0.6 3 0.4 2.2 0.6 3.4 0.4 2.4 0.6 3.8 1.1 284 11 269 165 11.9 0 12.2 11.7 07/14/2006 03:10:00 0.7 0.5 2.3 0.4 0.8 0.6 2.6 0.4 1.4 0.6 3 0.4 260 9 273 165 12.2 0.2 12.7 11.7 07/14/2006 03:20:00 0.7 0.4 1.9 0.4 0.8 0.5 1.9 0.4 1.5 0.4 2.3 0.7 270 12 265 165 12.3 0 12.5 12.2 07/14/2006 03:30:00 1.6 0.6 3 0.4 1.9 0.7 3 0.4 2.4 0.5 3.4 1.1 261 12 268 165 12.3 0 12.5 11.9 07/14/2006 03:40:00 2.3 0.3 3.4 1.5 2.5 0.3 3.4 1.5 2.4 0.5 3.4 1.1 289 7 291 165 11.9 0.2 12.5 11.7 07/14/2006 03:50:00 2.9 0.5 4.2 1.5 2.9 0.5 4.2 1.9 2.5 0.5 3.8 1.5 296 5 298 165 11.7 0 11.9 11.4 07/14/2006 04:00:00 3.2 0.4 4.2 2.3 3.3 0.4 4.2 2.3 2.6 0.5 3.8 1.5 297 4 300 165 11.7 0 11.9 11.7 07/14/2006 04:10:00 3.2 0.4 4.2 2.3 3.3 0.4 4.2 2.3 2.5 0.4 3.8 1.5 298 4 298 165 11.7 0.1 11.9 11.4 07/14/2006 04:20:00 3.6 0.4 4.2 2.6 3.7 0.4 4.2 2.6 2.8 0.4 4.2 1.9 299 3 301 165 11.7 0.1 11.9 11.4 07/14/2006 04:30:00 3.7 0.5 5.3 2.6 3.8 0.5 5.3 2.6 3.4 0.7 4.9 1.9 293 5 292 165 11.7 0 12.2 11.4 07/14/2006 04:40:00 4 0.5 5.3 3 4.1 0.5 5.3 3 3.7 0.6 5.3 2.3 293 5 301 165 11.7 0 11.9 11.4 07/14/2006 04:50:00 4.1 0.5 5.3 3 4.1 0.5 5.3 3 3.7 0.6 5.3 2.3 291 3 289 165 11.6 0 11.9 11.4 07/14/2006 05:00:00 4.5 0.4 5.3 3 4.6 0.4 5.3 3.4 4.1 0.5 5.7 2.6 290 4 295 165 11.7 0.1 11.9 11.4 07/14/2006 05:10:00 4.4 0.5 5.7 2.6 4.5 0.5 5.7 3 3.9 0.6 5.7 2.3 290 5 287 165 11.9 0 11.9 11.7 07/14/2006 05:20:00 4.7 0.4 5.7 3.4 4.7 0.4 5.7 3.4 3.9 0.6 5.3 2.3 294 5 290 165 11.7 0 11.9 11.4 07/14/2006 05:30:00 4.6 0.5 5.7 3.4 4.7 0.5 5.7 3.4 3.8 0.5 5.3 2.6 295 5 296 165 11.5 0 11.9 11.1 07/14/2006 05:40:00 5 0.5 6.5 3.8 5 0.5 6.5 3.8 3.9 0.6 6.5 2.6 296 5 292 165 11.2 0 11.4 11.1 07/14/2006 05:50:00 5.2 0.6 6.5 3.4 5.2 0.6 6.8 3.4 4.4 0.8 6.5 2.3 294 6 281 165 11.1 0 11.4 10.9 07/14/2006 06:00:00 5.2 0.5 6.8 3.8 5.2 0.5 6.8 4.2 4.5 0.6 5.7 2.6 290 5 291 165 11.1 0.1 11.4 10.9 07/14/2006 06:10:00 5 0.6 6.1 3 5 0.6 6.5 2.6 4.2 0.8 6.1 1.9 290 5 293 165 11.2 0 11.4 10.9 07/14/2006 06:20:00 4.9 0.6 6.5 3 4.9 0.6 6.8 3.4 4.2 0.8 6.5 2.3 291 5 286 165 11.2 0.1 11.7 10.9 07/14/2006 06:30:00 4.3 0.6 5.3 2.6 4.3 0.6 5.3 2.6 3.9 0.7 5.3 2.3 288 7 298 165 11.7 0.2 11.9 11.4 07/14/2006 06:40:00 4.4 0.4 5.7 3.4 4.5 0.4 5.7 3.4 4.2 0.7 5.7 1.9 291 5 303 165 11.9 0 12.2 11.7 07/14/2006 06:50:00 4.2 0.5 5.3 3 4.2 0.5 5.3 3 3.7 0.7 5.3 1.9 295 8 286 165 12 0 12.2 11.9 07/14/2006 07:00:00 3.6 0.5 4.9 2.3 3.6 0.5 4.6 2.3 2.9 0.4 4.2 1.5 300 5 304 165 12.1 0 12.5 11.9 07/14/2006 07:10:00 3.2 0.4 4.2 2.3 3.3 0.4 4.2 2.3 2.7 0.4 4.2 1.5 302 6 301 165 12.6 0.2 13 12.2 07/14/2006 07:20:00 2.2 0.4 3 1.1 2.3 0.4 3 1.1 1.9 0.4 3 1.1 300 6 302 165 13.3 0.1 13.5 13 07/14/2006 07:30:00 1.3 0.6 2.6 0.4 1.3 0.7 2.6 0.4 1.3 0.6 2.6 0.4 295 14 290 165 13.7 0.2 14.4 13.3 07/14/2006 07:40:00 1.4 0.5 2.6 0.4 1.7 0.7 3 0.4 1.9 0.7 3.4 0.4 268 16 243 165 14.2 0.2 14.6 13.5 07/14/2006 07:50:00 1.5 0.7 3.4 0.4 1.8 0.8 3.8 0.4 1.7 0.8 4.6 0.4 247 29 270 165 14.6 0.1 15.2 14.4 07/14/2006 08:00:00 2 0.6 3.4 0.4 2.7 0.9 4.2 0.7 2.9 0.7 4.2 1.1 262 9 259 165 14.4 0.3 15.2 13.8 07/14/2006 08:10:00 2.7 0.5 3.8 1.1 2.7 0.5 3.8 1.5 2.7 0.4 3.8 1.5 279 8 278 165 13.6 0.2 14.1 13 07/14/2006 08:20:00 3.2 0.5 4.6 1.9 3.1 0.6 4.6 1.9 3.3 0.6 4.6 1.9 282 9 270 165 12.7 0.2 13.3 12.2 07/14/2006 08:30:00 3 0.3 4.2 2.3 3 0.4 4.2 2.3 2.6 0.5 4.2 1.5 294 6 285 165 12.5 0.1 13 12.2 07/14/2006 08:40:00 3.4 0.4 4.2 2.3 3.3 0.4 4.2 2.3 3.2 0.6 4.6 1.9 289 6 284 165 12.9 0.2 13.3 12.5 07/14/2006 08:50:00 4.1 0.6 5.7 2.6 4.2 0.6 5.7 3 4.1 0.7 5.7 1.9 287 6 285 165 12.9 0.2 13.5 12.2 07/14/2006 09:00:00 4.1 0.5 5.7 2.6 4.1 0.6 6.1 2.3 3.7 0.6 5.3 1.9 289 6 280 165 12.5 0.1 12.7 11.9 07/14/2006 09:10:00 4 0.5 5.3 3 4 0.5 5.3 3 3.9 0.6 5.7 2.3 290 6 293 165 12.3 0 12.7 11.7 07/14/2006 09:20:00 3.3 0.5 4.6 1.9 3.3 0.5 4.6 1.9 3.2 0.6 4.6 1.5 290 5 282 165 12.4 0 12.7 11.7 07/14/2006 09:30:00 2.3 0.4 3 1.5 2.3 0.4 3.4 1.5 2.3 0.4 3.4 1.1 280 6 276 165 12.8 0 13 12.2 07/14/2006 09:40:00 1.9 0.5 3 0.7 2.1 0.5 3.4 0.7 1.9 0.5 3 0.4 276 7 284 165 12.9 0.1 13 12.5 07/14/2006 09:50:00 1.2 0.6 3 0.4 1.4 0.6 3 0.4 1.4 0.6 2.6 0.4 268 11 286 165 12.9 0.2 13 12.2 07/14/2006 10:00:00 2.4 0.8 4.2 0.4 2.6 0.7 4.2 0.7 2.3 0.8 4.2 0.4 277 8 269 165 12.9 0.1 13 12.2 07/14/2006 10:10:00 3 0.5 4.2 1.5 3.1 0.5 4.2 1.9 2.9 0.6 4.2 1.5 282 9 287 165 13 0 13.3 12.7 07/14/2006 10:20:00 2.6 0.5 4.2 1.1 2.7 0.5 4.6 1.1 2.7 0.6 4.6 1.5 286 8 284 165 13 0 13.3 12.7 07/14/2006 10:30:00 2 0.5 3 0.7 2.1 0.5 3.4 0.7 2.1 0.5 3.4 0.7 284 17 273 165 13.2 0 13.5 12.7 07/14/2006 10:40:00 1 0.5 2.6 0.4 1 0.6 2.6 0.4 1.3 0.6 3 0.4 171 56 246 165 13.1 0.1 13.5 12.7 07/14/2006 10:50:00 1.5 0.4 2.6 0.4 1.5 0.4 2.6 0.4 1.7 0.4 2.6 1.1 121 6 118 165 12.6 0.1 13 12.2 07/14/2006 11:00:00 1.2 0.3 1.9 0.4 1.1 0.4 2.3 0.4 1.5 0.3 2.3 0.7 129 6 134 165 12.4 0 12.5 11.9 07/14/2006 11:10:00 1.5 0.2 1.9 0.7 1.4 0.2 2.3 0.7 1.7 0.3 2.6 1.1 130 5 126 165 12.4 0.1 12.5 11.9 07/14/2006 11:20:00 1.4 0.3 1.9 0.7 1.2 0.3 1.9 0.7 1.7 0.2 2.3 1.1 131 2 128 165 12.2 0 12.5 11.7 07/14/2006 11:30:00 0.8 0.5 1.9 0.4 0.7 0.4 1.5 0.4 1.2 0.4 1.9 0.4 138 5 141 165 12.1 0.1 12.5 11.7 07/14/2006 11:40:00 1.4 0.6 2.6 0.4 1.4 0.7 2.6 0.4 1.7 0.5 2.6 0.7 126 5 120 165 12.3 0.2 12.5 11.7 07/14/2006 11:50:00 1.7 0.3 2.6 0.7 1.7 0.4 2.6 1.1 2 0.3 2.6 1.5 132 9 126 165 12.1 0.1 12.5 11.7 07/14/2006 12:00:00 1.6 0.3 2.3 0.7 1.6 0.3 2.3 0.7 1.9 0.3 2.6 0.7 138 8 140 165 11.9 0 12.2 11.9 07/14/2006 12:10:00 1.2 0.4 2.3 0.4 1.2 0.5 2.3 0.4 1.5 0.3 2.3 0.4 145 7 135 165 12 0 12.2 11.7 07/14/2006 12:20:00 1.3 0.4 2.3 0.4 1.3 0.5 2.3 0.4 1.5 0.4 2.3 0.7 144 14 156 165 12.3 0.1 12.5 11.9 07/14/2006 12:30:00 2.2 0.3 3.4 1.5 2.2 0.3 3 1.5 2.4 0.3 3.4 1.5 135 7 126 165 12.4 0 12.5 11.9 07/14/2006 12:40:00 2.6 0.4 3.4 1.5 2.6 0.4 3.8 1.9 2.7 0.4 3.8 1.5 132 4 129 165 12.4 0.1 12.7 11.9 07/14/2006 12:50:00 2.9 0.2 3.8 1.9 2.9 0.2 3.4 1.9 3 0.3 3.8 2.3 141 6 140 165 12.3 0.1 12.5 11.7 07/14/2006 13:00:00 3 0.3 3.8 2.3 2.9 0.3 3.4 2.3 3 0.3 3.8 2.3 152 5 152 165 11.9 0.1 12.5 11.1 07/14/2006 13:10:00 2.5 0.4 3.4 1.5 2.4 0.4 3 1.1 2.5 0.3 3.4 1.9 153 5 156 165 11.7 0 11.9 11.1 07/14/2006 13:20:00 2.6 0.3 3.4 1.9 2.4 0.4 3.4 1.5 2.5 0.4 3.4 1.9 157 5 157 165 11.9 0 12.2 11.7 07/14/2006 13:30:00 2.6 0.5 3.4 1.5 2.5 0.5 3.4 1.1 2.7 0.5 3.8 1.1 158 5 160 165 11.8 0.1 12.2 11.4 07/14/2006 13:40:00 2.7 0.4 3.4 1.9 2.6 0.4 3.8 1.5 2.9 0.4 3.8 1.9 145 9 147 165 12 0 12.5 11.7 07/14/2006 13:50:00 3.3 0.5 4.6 1.9 3.3 0.5 4.6 2.3 3.4 0.4 4.6 2.3 146 9 148 165 12.8 0.2 13 11.9 07/14/2006 14:00:00 3 0.3 3.8 2.3 3 0.3 4.2 2.3 3.1 0.3 4.2 2.6 149 6 137 165 12.7 0.1 13 11.9 07/14/2006 14:10:00 3.1 0.4 4.2 1.9 3 0.4 3.8 1.9 3.2 0.4 4.2 2.6 149 6 147 165 12.5 0.2 13 11.9 07/14/2006 14:20:00 3 0.3 3.8 2.3 2.8 0.3 3.8 2.3 2.9 0.4 3.8 1.9 153 7 151 165 12 0.1 12.2 11.4 07/14/2006 14:30:00 3.9 0.5 4.9 2.6 3.7 0.5 4.6 2.3 3.6 0.5 4.6 2.3 149 5 152 165 11.7 0 11.9 11.7 07/14/2006 14:40:00 4.1 0.4 4.9 3 4 0.4 4.9 3 4 0.3 4.9 3.4 144 5 146 165 11.7 0 11.9 11.7 07/14/2006 14:50:00 3.8 0.4 4.9 3 3.7 0.4 4.6 3 3.6 0.4 4.6 2.6 138 6 147 165 11.7 0 11.9 11.7 07/14/2006 15:00:00 3.1 0.3 3.8 2.3 3 0.3 3.8 2.3 2.9 0.3 3.8 2.3 132 4 133 165 11.7 0 11.9 11.7 07/14/2006 15:10:00 3.1 0.3 4.2 2.3 3 0.3 4.2 2.3 3 0.3 3.8 2.3 131 5 133 165 11.5 0 11.9 11.4 07/14/2006 15:20:00 3.2 0.2 3.8 2.6 3.2 0.2 3.8 2.6 3.1 0.3 3.8 2.3 123 5 130 165 11.4 0 11.7 11.4 07/14/2006 15:30:00 2.5 0.3 3.4 1.9 2.5 0.3 3.4 1.9 2.4 0.3 3.4 1.5 118 6 115 165 11.6 0 11.7 11.4 07/14/2006 15:40:00 2.5 0.3 3 1.9 2.4 0.3 3 1.9 2.5 0.3 3.4 1.9 124 3 126 165 11.7 0 11.9 11.7 07/14/2006 15:50:00 1.8 0.4 2.6 0.7 1.8 0.4 2.6 0.7 1.7 0.4 2.6 1.1 114 7 125 165 11.7 0 11.9 11.7 07/14/2006 16:00:00 0.6 0.3 1.5 0.4 0.5 0.3 1.5 0.4 0.8 0.3 1.5 0.4 98 4 94 165 11.8 0 11.9 11.7 07/14/2006 16:10:00 0.4 0 0.7 0.4 0.4 0 0.4 0.4 0.4 0.1 1.1 0.4 134 94 338 165 12 0 12.5 11.9 07/14/2006 16:20:00 1.4 0.5 2.3 0.4 0.9 0.5 1.9 0.4 1.5 0.4 2.3 0.7 332 15 344 165 12.7 0.1 13 12.2 07/14/2006 16:30:00 1.6 0.5 2.6 0.4 0.9 0.4 1.9 0.4 1.7 0.5 3 0.7 354 6 1 165 13.4 0.3 13.8 13 07/14/2006 16:40:00 1.9 0.5 3.4 0.4 1.3 0.6 2.6 0.4 1.9 0.5 3.4 0.4 357 11 3 165 14 0 14.4 13.5 07/14/2006 16:50:00 2.4 0.4 3.4 1.5 1.8 0.6 3.4 0.4 2.4 0.4 3.4 1.5 8 9 16 165 13.9 0.1 14.4 13.3 07/14/2006 17:00:00 2.5 0.4 3.4 1.1 2 0.5 3.4 0.7 2.5 0.3 3.4 1.5 11 11 360 165 13.5 0 13.8 13 07/14/2006 17:10:00 2.5 0.4 3.4 1.5 2 0.5 3.4 0.7 2.7 0.4 3.8 1.5 13 7 29 165 13.3 0 13.5 12.5 07/14/2006 17:20:00 3 0.4 4.2 1.9 2.2 0.6 4.2 0.7 2.9 0.4 3.8 1.9 8 9 336 165 12.9 0.1 13.3 12.5 07/14/2006 17:30:00 3 0.4 4.2 1.9 2.5 0.5 4.2 1.5 2.9 0.5 4.6 1.9 13 10 26 165 12.8 0 13 11.9 07/14/2006 17:40:00 2.9 0.4 4.2 1.9 2.2 0.6 3.4 0.7 2.9 0.5 4.6 1.5 10 10 13 165 12.5 0.1 12.7 12.5 07/14/2006 17:50:00 3 0.4 4.2 1.9 2.1 0.5 3.4 1.1 3 0.5 4.2 1.5 5 10 8 165 12.4 0 12.5 12.2 07/14/2006 18:00:00 2.5 0.3 3.4 1.9 1.7 0.5 2.6 0.7 2.4 0.3 3 1.5 354 7 2 165 12.5 0 12.7 12.2 07/14/2006 18:10:00 1.4 0.6 2.6 0.4 0.8 0.5 2.3 0.4 1.4 0.6 2.3 0.4 354 11 352 165 12.7 0 13 12.5 07/14/2006 18:20:00 0.8 0.6 2.3 0.4 0.7 0.5 2.3 0.4 0.7 0.4 1.5 0.4 301 15 308 165 12.8 0 13 12.5 07/14/2006 18:30:00 0.4 0.1 1.1 0.4 0.4 0 0.4 0.4 0.4 0.2 1.1 0.4 280 22 205 165 13.1 0 13.3 12.5 07/14/2006 18:40:00 1.1 0.4 1.9 0.4 0.7 0.5 1.9 0.4 1.3 0.4 1.9 0.4 194 11 205 165 12.9 0.2 13.3 12.5 07/14/2006 18:50:00 1.8 0.4 2.6 0.7 1.5 0.5 2.3 0.4 1.9 0.4 2.6 0.7 174 8 181 165 12.5 0.2 12.7 11.9 07/14/2006 19:00:00 1.6 0.3 2.3 0.7 1.3 0.4 2.3 0.4 1.8 0.4 2.6 0.7 191 8 192 165 12.5 0 12.7 12.2 07/14/2006 19:10:00 1.6 0.2 2.3 1.1 1.2 0.3 1.9 0.4 1.8 0.3 2.3 1.1 183 4 173 165 12.2 0.1 12.5 11.9 07/14/2006 19:20:00 1 0.5 1.9 0.4 0.6 0.4 1.5 0.4 0.9 0.5 1.9 0.4 177 1 174 165 11.9 0 12.2 11.9 07/14/2006 19:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.7 0.4 177 0 165 165 12.1 0 12.2 11.9 07/14/2006 19:40:00 0.5 0.2 1.1 0.4 0.4 0 0.4 0.4 0.6 0.3 1.1 0.4 177 0 177 165 12.1 0 12.2 11.9 07/14/2006 19:50:00 0.6 0.3 1.5 0.4 0.4 0 0.4 0.4 0.6 0.3 1.5 0.4 167 2 173 165 12.1 0 12.2 11.9 07/14/2006 20:00:00 0.6 0.3 1.1 0.4 0.4 0 0.4 0.4 0.6 0.3 1.1 0.4 167 0 167 165 12 0 12.2 11.9 07/14/2006 20:10:00 0.4 0.1 1.1 0.4 0.4 0 0.4 0.4 0.4 0.2 1.1 0.4 167 0 167 165 11.9 0 12.2 11.7 07/14/2006 20:20:00 0.8 0.4 1.9 0.4 0.5 0.3 1.9 0.4 0.8 0.4 1.5 0.4 197 16 212 165 11.5 0 11.7 11.4 07/14/2006 20:30:00 0.4 0.2 1.5 0.4 0.4 0 0.4 0.4 0.5 0.2 1.1 0.4 212 0 212 165 11.6 0 11.9 11.4 07/14/2006 20:40:00 0.8 0.5 2.3 0.4 0.7 0.5 1.9 0.4 0.7 0.4 1.9 0.4 275 17 291 165 11.8 0 11.9 11.7 07/14/2006 20:50:00 1.9 0.5 3.4 0.7 1.9 0.6 3.4 0.4 1.7 0.5 3 0.7 285 6 282 165 11.7 0 11.9 11.7 07/14/2006 21:00:00 2.7 0.3 3.4 1.9 2.8 0.3 3.4 1.9 2.8 0.3 3.4 1.9 281 3 278 165 11.6 0 11.9 11.4 07/14/2006 21:10:00 2.4 0.6 3.8 1.5 2.4 0.7 4.2 1.1 2.1 0.5 3.8 1.1 299 7 290 165 11.5 0 11.7 11.4 07/14/2006 21:20:00 1.9 0.5 3 0.7 2 0.5 3 0.7 1.8 0.5 3 0.7 302 9 317 165 11.4 0 11.7 11.1 07/14/2006 21:30:00 2.1 0.5 3 1.1 2.1 0.6 3.4 0.7 1.9 0.6 3.4 0.7 294 9 301 165 11.5 0 11.7 11.1 07/14/2006 21:40:00 1.4 0.4 2.6 0.4 1.3 0.6 2.6 0.4 1.3 0.5 2.3 0.4 295 7 296 165 11.5 0 11.7 11.4 07/14/2006 21:50:00 1.9 0.4 2.6 1.1 2 0.5 3 0.7 1.6 0.3 2.3 0.7 298 4 302 165 11.5 0 11.7 11.1 07/14/2006 22:00:00 2.3 0.6 3.4 0.7 2.4 0.6 3.4 0.7 2.1 0.6 3.4 0.7 291 5 291 165 11.3 0.1 11.7 11.1 07/14/2006 22:10:00 3.5 0.3 4.2 2.6 3.5 0.3 4.2 2.6 2.9 0.4 3.8 1.9 294 5 291 165 11.2 0.1 11.7 10.9 07/14/2006 22:20:00 3.1 0.4 4.2 2.3 3.2 0.4 4.2 2.3 2.8 0.4 3.8 1.9 291 6 297 165 11.1 0 11.4 10.9 07/14/2006 22:30:00 3.6 0.3 4.2 3 3.6 0.3 4.2 3 2.7 0.4 4.2 1.9 296 3 295 165 11 0.1 11.1 10.9 07/14/2006 22:40:00 3.4 0.4 4.2 2.6 3.3 0.4 4.2 2.6 2.9 0.3 3.8 1.9 307 5 300 165 10.9 0 11.1 10.6 07/14/2006 22:50:00 3.6 0.5 4.6 2.3 3.6 0.5 4.6 2.3 3.3 0.4 4.2 2.3 309 5 304 165 10.9 0 11.1 10.6 07/14/2006 23:00:00 2.7 0.4 3.8 1.5 2.6 0.5 3.8 1.1 2.8 0.4 3.8 1.9 328 12 314 165 10.7 0.2 11.1 10.3 07/14/2006 23:10:00 3.3 0.5 4.9 2.3 3.3 0.5 4.9 2.3 3.3 0.4 4.6 1.9 318 8 313 165 10.7 0.1 11.1 10.3 07/14/2006 23:20:00 3.9 0.7 5.3 2.3 3.9 0.7 4.9 2.3 3.2 0.4 4.2 1.9 305 6 300 165 10.6 0.2 10.9 10.3 07/14/2006 23:30:00 4.2 0.3 4.9 3 4.1 0.3 4.9 3 3.7 0.5 4.6 2.3 308 5 309 165 10.6 0.2 11.1 10.3 07/14/2006 23:40:00 4.4 0.4 5.7 3.4 4.3 0.4 5.3 3.4 3.4 0.4 4.6 2.3 303 4 300 165 10.6 0.2 10.9 10.3 07/14/2006 23:50:00 5 0.4 6.1 4.2 5 0.4 6.5 3.8 3.7 0.4 4.9 2.6 300 4 297 165 10.6 0.2 11.1 10.3 07/15/2006 00:00:00 4.7 0.4 5.7 3.4 4.7 0.4 5.7 3.4 3.7 0.5 4.9 2.6 304 5 298 165 10.6 0.2 10.9 10.3 07/15/2006 00:10:00 4.6 0.5 6.1 3.4 4.6 0.5 6.1 3.4 3.5 0.5 4.9 2.3 300 5 296 165 10.6 0.2 10.9 10.3 07/15/2006 00:20:00 5 0.5 6.1 3.8 5 0.5 6.5 3.8 3.8 0.5 5.3 2.6 297 6 305 165 10.7 0.1 10.9 10.3 07/15/2006 00:30:00 5.3 0.6 6.8 3.8 5.4 0.6 6.8 3.8 4.3 0.7 6.1 2.6 294 6 295 165 10.7 0.1 10.9 10.3 07/15/2006 00:40:00 6.1 0.5 7.2 4.9 6.1 0.5 7.6 4.9 4.5 0.6 6.1 3 296 5 300 165 10.6 0 10.9 10.1 07/15/2006 00:50:00 5.7 0.4 6.5 4.6 5.7 0.4 6.5 4.6 4.1 0.6 6.1 2.6 301 5 289 165 10.4 0 10.9 10.3 07/15/2006 01:00:00 5.8 0.5 7.2 4.2 5.8 0.5 7.2 4.2 4.3 0.6 6.1 3 300 5 300 165 10.4 0 10.6 10.1 07/15/2006 01:10:00 5.6 0.6 6.8 4.2 5.6 0.6 6.8 4.2 4.2 0.6 6.1 2.3 302 5 309 165 10.3 0 10.6 10.1 07/15/2006 01:20:00 5.3 0.6 6.8 3.4 5.3 0.6 6.8 3.8 4.1 0.6 5.7 2.6 303 5 302 165 10.3 0 10.6 10.1 07/15/2006 01:30:00 4.8 0.5 6.1 3.8 4.8 0.5 6.1 3.4 3.7 0.5 5.3 2.3 302 6 301 165 10.2 0 10.9 10.1 07/15/2006 01:40:00 4.6 0.6 6.1 3.4 4.6 0.6 6.1 3.4 3.6 0.6 4.9 2.3 301 7 300 165 10.3 0 10.9 10.3 07/15/2006 01:50:00 4.7 0.6 6.1 3 4.7 0.5 6.1 3.4 3.7 0.6 5.3 2.6 304 6 300 165 10.3 0 10.9 10.3 07/15/2006 02:00:00 4.7 0.6 6.1 3.4 4.7 0.6 6.1 3.4 3.9 0.6 5.7 2.6 305 6 309 165 10.3 0 10.6 10.3 07/15/2006 02:10:00 4.8 0.4 6.1 3.8 4.9 0.4 6.1 3.8 3.8 0.6 5.3 2.6 298 5 298 165 10.3 0 10.6 10.3 07/15/2006 02:20:00 5.2 0.5 7.2 4.2 5.3 0.5 6.8 4.2 4.3 0.7 6.1 2.6 291 5 286 165 10.4 0 10.6 10.3 07/15/2006 02:30:00 5 0.5 6.1 3.4 5 0.5 6.1 3.4 4.2 0.7 5.7 2.3 291 5 289 165 10.4 0 10.6 10.3 07/15/2006 02:40:00 5 0.4 6.1 4.2 5.1 0.4 6.1 4.2 4.5 0.5 5.7 3.4 288 4 277 165 10.4 0 10.9 10.3 07/15/2006 02:50:00 4.5 0.4 5.3 3.4 4.6 0.4 5.7 3.4 4.2 0.6 5.3 2.3 289 3 287 165 10.4 0 10.9 10.3 07/15/2006 03:00:00 4.1 0.5 5.3 2.6 4.2 0.5 5.3 2.6 3.5 0.7 5.3 2.3 290 5 293 165 10.4 0 10.6 10.3 07/15/2006 03:10:00 4.6 0.3 5.3 3.4 4.8 0.3 5.7 3.8 4.6 0.6 5.7 3 283 3 279 165 10.3 0 10.6 10.3 07/15/2006 03:20:00 4 0.3 4.6 3 4.1 0.3 4.9 3.4 3.9 0.5 4.9 1.9 287 4 282 165 10.4 0 10.6 10.3 07/15/2006 03:30:00 4.3 0.4 5.7 3.4 4.3 0.4 5.7 3.4 3.5 0.6 4.9 2.3 293 4 297 165 10.4 0 11.1 10.3 07/15/2006 03:40:00 4 0.3 4.6 3 4.1 0.3 4.9 3 3.6 0.6 4.9 2.3 294 5 295 165 10.4 0 10.9 10.1 07/15/2006 03:50:00 3.2 0.4 4.2 2.3 3.3 0.4 4.2 2.3 2.6 0.4 3.8 1.9 300 4 304 165 10.4 0 10.6 10.3 07/15/2006 04:00:00 2.6 0.2 3.4 1.9 2.7 0.2 3.4 1.9 2.1 0.3 3 1.5 297 3 290 165 10.4 0 10.6 10.3 07/15/2006 04:10:00 2.6 0.4 3.4 1.5 3.1 0.3 3.8 2.6 2.9 0.4 3.8 1.9 283 10 292 165 10.4 0 10.6 10.1 07/15/2006 04:20:00 1.3 0.9 3.4 0.4 1.6 1 3.4 0.4 1.4 0.9 3.4 0.4 257 18 280 165 10 0.1 10.6 9.6 07/15/2006 04:30:00 1.3 0.6 3 0.4 1.7 0.8 3.4 0.4 1.4 0.8 3 0.4 249 18 272 165 10 0.1 10.3 9.6 07/15/2006 04:40:00 1.9 0.4 3 1.1 3 0.3 3.8 2.3 2.9 0.3 3.4 2.3 265 3 270 165 10.1 0.1 10.3 9.6 07/15/2006 04:50:00 2.6 0.4 3.4 1.5 2.8 0.2 3.4 2.3 2.8 0.2 3.4 2.3 277 10 283 165 10.1 0 10.3 9.8 07/15/2006 05:00:00 2.6 0.3 3.4 1.9 2.7 0.3 3.4 2.3 2.4 0.4 3.4 1.5 290 2 287 165 10.1 0.1 10.6 9.8 07/15/2006 05:10:00 2.7 0.3 3.4 2.3 2.8 0.2 3.8 2.3 2.5 0.3 3.4 1.9 289 2 291 165 10.1 0 10.3 9.8 07/15/2006 05:20:00 2.9 0.3 3.4 2.3 2.9 0.3 3.8 2.3 2.5 0.4 3.4 1.5 293 6 285 165 10.2 0 10.6 9.8 07/15/2006 05:30:00 2.1 0.3 3 1.1 2.3 0.3 3.4 1.1 1.8 0.4 3 1.1 295 3 295 165 10.1 0.1 10.3 9.8 07/15/2006 05:40:00 1.4 0.4 2.3 0.4 1.6 0.4 2.6 1.1 1.6 0.2 2.3 1.1 284 10 293 165 10.2 0.1 10.6 9.8 07/15/2006 05:50:00 0.5 0.2 1.1 0.4 0.7 0.4 1.5 0.4 1 0.5 1.9 0.4 266 0 266 165 10.5 0.1 10.9 10.3 07/15/2006 06:00:00 0.5 0.2 1.1 0.4 0.5 0.2 1.1 0.4 1.2 0.5 1.9 0.4 232 19 231 165 10.4 0 10.9 10.1 07/15/2006 06:10:00 1.1 0.4 1.9 0.4 1.3 0.5 2.3 0.4 1.7 0.3 2.3 0.7 236 3 232 165 10.3 0 10.6 10.1 07/15/2006 06:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.6 0.3 1.5 0.4 228 4 165 165 10.3 0 10.6 9.8 07/15/2006 06:30:00 0.7 0.4 1.5 0.4 0.7 0.4 1.5 0.4 1.2 0.3 1.9 0.4 184 23 167 165 10.3 0.1 10.9 10.1 07/15/2006 06:40:00 1.1 0.6 2.3 0.4 1 0.6 2.3 0.4 1.4 0.5 2.3 0.4 160 9 149 165 10.1 0 10.6 9.8 07/15/2006 06:50:00 1.1 0.5 1.9 0.4 1 0.4 1.9 0.4 1.3 0.4 1.9 0.4 143 6 148 165 10 0 10.1 9.6 07/15/2006 07:00:00 0.5 0.3 1.5 0.4 0.4 0.2 1.5 0.4 0.7 0.4 1.9 0.4 133 0 134 165 10 0 10.3 9.6 07/15/2006 07:10:00 0.4 0.1 1.1 0.4 0.4 0.1 1.1 0.4 0.6 0.3 1.5 0.4 131 4 134 165 10 0 10.3 9.8 07/15/2006 07:20:00 0.6 0.4 1.5 0.4 0.5 0.3 1.5 0.4 0.8 0.5 1.9 0.4 128 4 125 165 10 0 10.3 9.8 07/15/2006 07:30:00 0.4 0 0.7 0.4 0.4 0 0.4 0.4 0.5 0.3 1.5 0.4 125 9 134 165 10 0 10.3 9.8 07/15/2006 07:40:00 0.5 0.3 1.5 0.4 0.4 0.1 1.1 0.4 0.8 0.4 1.9 0.4 112 3 108 165 10.1 0 10.6 9.6 07/15/2006 07:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0.1 1.1 0.4 104 3 165 165 10.3 0 10.6 9.6 07/15/2006 08:00:00 0.5 0.2 1.5 0.4 0.4 0.2 1.5 0.4 0.7 0.5 1.9 0.4 104 3 104 165 10.4 0 10.9 9.8 07/15/2006 08:10:00 0.4 0 0.7 0.4 0.4 0 0.4 0.4 0.6 0.3 1.5 0.4 87 10 84 165 10.3 0.1 10.9 9.6 07/15/2006 08:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0.1 0.7 0.4 83 0 165 165 10.7 0.2 11.1 10.1 07/15/2006 08:30:00 0.4 0 0.7 0.4 0.4 0 0.7 0.4 0.5 0.3 1.5 0.4 101 20 84 165 11.1 0.2 11.7 10.9 07/15/2006 08:40:00 0.6 0.4 1.9 0.4 0.5 0.3 1.5 0.4 0.9 0.4 2.3 0.4 109 8 120 165 11.6 0.1 11.9 11.1 07/15/2006 08:50:00 1 0.6 2.6 0.4 0.9 0.6 2.3 0.4 1.3 0.6 2.6 0.4 122 11 145 165 12 0.3 12.5 11.7 07/15/2006 09:00:00 2.2 0.6 3.8 0.7 2.3 0.6 3.4 0.7 2.5 0.5 3.8 1.1 122 12 116 165 12.7 0.2 13.3 12.5 07/15/2006 09:10:00 2.7 0.6 4.6 1.1 2.6 0.7 4.6 0.7 2.8 0.8 4.6 0.7 123 16 119 165 13.3 0.2 13.8 12.7 07/15/2006 09:20:00 2.8 0.5 4.2 1.5 2.7 0.5 4.2 1.9 3 0.4 4.2 1.9 138 9 122 165 12.1 0.3 13 11.7 07/15/2006 09:30:00 2.4 0.5 4.2 1.1 2.4 0.5 4.2 1.1 2.6 0.5 3.8 1.5 125 12 121 165 11.7 0 11.9 11.4 07/15/2006 09:40:00 2 0.4 3 1.1 1.9 0.4 3 0.7 2.3 0.3 3.4 1.5 129 9 121 165 11.2 0.2 11.7 10.9 07/15/2006 09:50:00 1.9 0.4 3.4 1.1 1.9 0.4 3 1.1 2.3 0.3 3.4 1.5 125 10 128 165 10.9 0 11.1 10.6 07/15/2006 10:00:00 2.4 0.5 3.4 1.1 2.2 0.5 3.4 1.1 2.5 0.4 3.4 1.9 136 7 133 165 11.4 0 11.7 10.6 07/15/2006 10:10:00 2.8 0.4 3.8 1.9 2.6 0.4 3.8 1.5 2.8 0.4 3.8 1.9 132 9 137 165 11.6 0 11.9 11.1 07/15/2006 10:20:00 2.5 0.5 3.8 1.5 2.4 0.5 3.8 1.1 2.6 0.4 3.8 1.9 127 10 135 165 11.5 0.3 11.9 10.9 07/15/2006 10:30:00 2 0.3 2.6 1.1 1.7 0.4 2.6 0.4 2.1 0.3 3 1.1 123 8 133 165 11.1 0 11.4 10.6 07/15/2006 10:40:00 1.8 0.4 2.6 0.7 1.5 0.4 2.6 0.4 1.8 0.4 2.6 0.4 128 9 145 165 11.2 0 11.4 11.1 07/15/2006 10:50:00 2.4 0.4 3.4 1.5 2.2 0.3 3.4 1.1 2.5 0.3 3.4 1.9 132 7 136 165 11.3 0 11.7 11.1 07/15/2006 11:00:00 2.1 0.3 3 1.5 1.9 0.4 2.6 1.1 2.1 0.3 3 1.1 124 8 130 165 11.3 0.1 11.7 10.9 07/15/2006 11:10:00 2.4 0.4 3.8 1.5 2.2 0.5 4.2 1.5 2.4 0.4 4.2 1.5 128 9 140 165 11.5 0 11.7 11.1 07/15/2006 11:20:00 2.9 0.4 3.8 1.9 2.8 0.4 3.8 1.9 3 0.4 4.2 1.9 125 5 118 165 11.6 0 11.9 11.1 07/15/2006 11:30:00 3.8 0.4 5.3 3 3.7 0.5 5.3 2.6 3.7 0.4 4.9 2.6 127 8 128 165 11.9 0 12.2 11.4 07/15/2006 11:40:00 3.7 0.4 4.9 2.6 3.6 0.5 4.9 2.3 3.8 0.4 5.3 2.6 130 7 137 165 11.6 0 11.9 11.1 07/15/2006 11:50:00 4.1 0.5 5.3 2.6 3.9 0.5 5.3 2.6 4 0.5 4.9 3 132 7 121 165 11.7 0.1 12.2 11.4 07/15/2006 12:00:00 3.9 0.4 5.3 3 3.7 0.5 4.9 2.6 3.9 0.4 4.9 3 130 7 124 165 11.8 0 12.2 11.4 07/15/2006 12:10:00 3.9 0.4 5.3 3 3.7 0.5 4.9 2.6 3.9 0.4 5.3 3 128 7 118 165 11.8 0 11.9 11.7 07/15/2006 12:20:00 3.9 0.5 5.3 2.6 3.7 0.5 5.3 2.3 3.9 0.5 5.3 3 128 6 126 165 12 0.1 12.2 11.7 07/15/2006 12:30:00 3.6 0.5 4.6 2.3 3.4 0.5 4.9 2.3 3.7 0.5 4.9 1.9 129 10 118 165 11.9 0 12.2 11.7 07/15/2006 12:40:00 3.5 0.5 4.9 2.3 3.3 0.6 4.9 1.5 3.6 0.5 5.3 2.6 127 8 139 165 12 0.2 12.5 11.7 07/15/2006 12:50:00 3.6 0.7 5.3 1.9 3.4 0.8 5.3 1.5 3.7 0.7 5.7 1.9 137 13 148 165 12.5 0.1 12.7 11.9 07/15/2006 13:00:00 3.7 0.8 5.3 1.5 3.4 0.8 5.3 1.5 3.6 0.9 5.7 1.1 139 15 122 165 13 0.1 13.3 12.5 07/15/2006 13:10:00 3.8 0.6 4.9 1.9 3.6 0.7 4.9 1.5 3.8 0.6 5.7 1.9 136 10 136 165 13.3 0 13.5 13 07/15/2006 13:20:00 3.3 0.6 5.3 1.9 3 0.7 4.9 1.5 3.4 0.7 5.3 1.5 142 13 130 165 13.3 0 13.5 13 07/15/2006 13:30:00 3.3 0.5 4.6 1.9 3 0.6 4.6 1.5 3.4 0.5 4.6 2.3 139 11 149 165 13.2 0.1 13.5 13 07/15/2006 13:40:00 3.6 0.5 4.9 2.6 3.4 0.6 4.9 1.9 3.8 0.5 4.9 2.3 145 9 133 165 14.2 0.2 14.6 13.5 07/15/2006 13:50:00 3.8 0.6 5.7 2.6 3.5 0.7 5.3 1.9 3.9 0.6 6.1 2.6 145 10 154 165 14.2 0.5 15.2 13.3 07/15/2006 14:00:00 3.9 0.6 5.3 2.6 3.7 0.6 5.7 2.3 3.8 0.7 5.3 2.3 145 12 144 165 14 0.3 14.6 13.3 07/15/2006 14:10:00 3.7 0.4 4.9 2.6 3.5 0.5 4.6 2.3 3.8 0.5 5.3 2.6 146 9 125 165 13.7 0.2 14.4 13.3 07/15/2006 14:20:00 3.6 0.4 4.6 2.3 3.4 0.5 4.9 2.3 3.7 0.5 5.3 2.6 146 8 146 165 13.4 0 13.8 13 07/15/2006 14:30:00 3.2 0.5 4.6 1.9 3.1 0.6 4.6 1.5 3.3 0.6 5.3 1.9 147 9 152 165 13.1 0 13.3 13 07/15/2006 14:40:00 2.9 0.5 4.2 1.5 2.8 0.5 3.8 1.5 3 0.4 4.2 1.9 145 10 147 165 13 0 13.3 12.7 07/15/2006 14:50:00 2.6 0.5 4.2 1.5 2.4 0.6 3.8 1.1 2.7 0.5 4.2 1.5 144 12 150 165 12.7 0 13 12.5 07/15/2006 15:00:00 2.7 0.4 4.2 1.1 2.5 0.5 3.8 1.1 2.6 0.5 4.2 1.5 138 15 147 165 12.7 0 13 12.5 07/15/2006 15:10:00 2.4 0.3 3.8 1.5 2.2 0.4 3.4 1.5 2.3 0.4 3.4 1.5 131 10 130 165 12.7 0 13 12.2 07/15/2006 15:20:00 2.4 0.5 3.4 1.1 2.1 0.5 3.4 0.4 2.3 0.5 3.8 0.7 126 13 121 165 12.7 0 13 12.2 07/15/2006 15:30:00 2.4 0.3 3.4 1.5 2.2 0.4 3 0.7 2.3 0.4 3.4 1.5 127 10 144 165 12.7 0 13 11.9 07/15/2006 15:40:00 2.2 0.4 3.4 1.1 2 0.4 3.4 0.7 2 0.4 3 0.7 129 12 131 165 12.7 0 13 12.5 07/15/2006 15:50:00 2.2 0.4 3 1.1 2 0.4 2.6 0.4 2.1 0.4 3 1.1 128 11 116 165 12.9 0 13 12.7 07/15/2006 16:00:00 2.2 0.4 3.4 0.7 1.9 0.5 3 0.4 2 0.4 3 0.4 126 8 152 165 12.7 0 13 12.5 07/15/2006 16:10:00 2.1 0.3 3 1.1 1.8 0.3 2.6 0.7 2 0.3 2.6 1.1 129 8 129 165 12.9 0 13 12.7 07/15/2006 16:20:00 1.7 0.3 2.6 0.7 1.3 0.5 2.3 0.4 1.6 0.3 2.6 0.7 134 12 136 165 12.8 0 13.3 12.5 07/15/2006 16:30:00 1.7 0.3 2.3 0.7 1.3 0.5 2.3 0.4 1.6 0.3 2.6 0.4 131 9 130 165 12.7 0 13 12.7 07/15/2006 16:40:00 2.2 0.2 2.6 1.9 1.9 0.2 2.3 1.5 2 0.3 2.3 0.7 129 4 126 165 12.8 0 13 12.7 07/15/2006 16:50:00 2.2 0.2 3 1.1 1.9 0.3 2.3 0.7 2.1 0.3 3 1.5 136 6 125 165 12.9 0 13 12.7 07/15/2006 17:00:00 2.1 0.3 3 1.1 1.8 0.3 2.6 1.1 1.9 0.3 2.6 1.1 125 9 122 165 12.9 0 13 12.7 07/15/2006 17:10:00 1.9 0.3 2.3 1.1 1.6 0.4 2.3 0.4 1.8 0.2 2.6 1.1 137 9 119 165 12.9 0 13 12.7 07/15/2006 17:20:00 1.7 0.3 2.3 1.1 1.3 0.5 2.3 0.4 1.8 0.2 2.3 1.1 140 6 146 165 13.1 0 13.3 12.7 07/15/2006 17:30:00 2 0.3 2.6 1.1 1.7 0.4 2.6 0.7 2 0.3 2.6 1.1 139 8 145 165 13 0 13.3 12.7 07/15/2006 17:40:00 2.3 0.3 3 1.5 2 0.3 2.6 1.5 2.2 0.3 3 1.5 139 6 142 165 13 0 13.3 12.7 07/15/2006 17:50:00 2.1 0.3 3 1.5 2 0.3 2.6 1.1 2.1 0.3 2.6 1.1 140 6 138 165 13 0 13.3 12.7 07/15/2006 18:00:00 1.8 0.3 2.3 1.1 1.5 0.4 2.3 0.4 1.8 0.3 2.3 0.7 137 8 158 165 13.1 0.1 13.3 12.7 07/15/2006 18:10:00 1.5 0.3 2.3 0.7 1.1 0.4 1.9 0.4 1.6 0.3 2.6 0.4 150 7 147 165 13.1 0 13.3 12.7 07/15/2006 18:20:00 1.7 0.3 2.3 0.7 1.4 0.4 2.3 0.4 1.7 0.2 2.3 1.1 145 6 150 165 13 0.1 13.3 12.7 07/15/2006 18:30:00 1.8 0.3 2.6 0.7 1.5 0.5 2.3 0.4 1.9 0.2 2.6 1.1 144 9 145 165 12.9 0 13.3 12.7 07/15/2006 18:40:00 1.8 0.3 2.3 1.1 1.3 0.5 1.9 0.4 1.8 0.3 2.3 1.1 141 8 144 165 12.8 0 13 12.5 07/15/2006 18:50:00 1.7 0.3 2.3 0.7 1.2 0.5 2.3 0.4 1.8 0.3 2.6 1.1 138 8 147 165 12.9 0 13 12.5 07/15/2006 19:00:00 2 0.3 3 1.1 1.7 0.3 2.6 0.7 2.1 0.2 2.6 1.5 140 6 125 165 12.9 0 13 12.5 07/15/2006 19:10:00 2.4 0.2 3 1.9 2.1 0.2 2.6 1.1 2.4 0.2 3 1.9 147 5 144 165 12.9 0.1 13 12.5 07/15/2006 19:20:00 2.4 0.3 3 1.9 2.2 0.3 3 1.5 2.5 0.3 3 1.5 149 6 149 165 12.8 0.1 13 12.5 07/15/2006 19:30:00 2.9 0.3 3.4 1.9 2.6 0.3 3 1.9 2.9 0.3 3.4 2.3 154 6 149 165 12.8 0 13 12.5 07/15/2006 19:40:00 3.3 0.3 4.2 2.6 3 0.3 3.8 2.3 3.3 0.3 4.2 2.6 152 4 149 165 12.7 0 12.7 12.5 07/15/2006 19:50:00 3.3 0.5 4.6 1.9 3 0.5 4.2 1.9 3.3 0.5 4.6 2.3 157 7 157 165 12.4 0 12.7 12.5 07/15/2006 20:00:00 3.3 0.5 4.2 2.3 3 0.5 3.8 1.9 3.3 0.4 4.2 2.3 159 5 155 165 12.4 0 12.5 12.2 07/15/2006 20:10:00 3.5 0.5 4.6 2.3 3.2 0.5 4.2 1.9 3.5 0.5 4.6 2.3 163 8 164 165 12.3 0 12.5 11.9 07/15/2006 20:20:00 3.4 0.5 4.6 2.6 3.1 0.5 4.2 1.9 3.4 0.4 4.2 2.6 158 7 164 165 12.1 0 12.5 11.9 07/15/2006 20:30:00 3.6 0.4 4.6 2.6 3.3 0.4 4.6 2.3 3.5 0.4 4.2 2.3 159 9 165 165 12.1 0 12.2 11.7 07/15/2006 20:40:00 3.7 0.5 4.6 2.3 3.5 0.5 4.6 2.3 3.5 0.4 4.6 2.6 157 11 163 165 12.1 0 12.2 11.9 07/15/2006 20:50:00 3.2 0.3 4.2 2.6 3.1 0.3 3.8 2.3 3.2 0.3 3.8 2.3 156 6 153 165 12 0 12.2 11.7 07/15/2006 21:00:00 3.2 0.3 4.2 2.3 3.2 0.3 3.8 2.3 3.2 0.3 3.8 2.6 153 5 156 165 11.9 0 12.2 11.7 07/15/2006 21:10:00 3.1 0.3 3.8 2.3 3 0.3 3.8 2.3 3 0.3 3.8 2.3 154 6 143 165 11.8 0.1 12.2 11.4 07/15/2006 21:20:00 3.1 0.5 4.2 1.9 3 0.5 4.2 1.5 3 0.4 4.2 2.3 158 5 156 165 11.9 0.1 12.2 11.4 07/15/2006 21:30:00 3.3 0.4 4.2 2.3 3.2 0.3 4.2 2.3 3.2 0.4 4.2 2.3 155 6 160 165 12 0 12.2 11.4 07/15/2006 21:40:00 2.8 0.4 3.8 1.9 2.7 0.4 3.8 1.5 2.7 0.4 3.4 1.1 152 7 153 165 11.9 0.1 12.2 11.4 07/15/2006 21:50:00 1.9 0.3 2.6 1.1 1.6 0.4 2.6 0.7 2 0.4 2.6 1.1 158 6 165 165 12 0 12.5 11.4 07/15/2006 22:00:00 2.2 0.4 3 1.1 1.9 0.4 2.6 0.7 2 0.3 3 1.5 168 5 170 165 12.1 0 12.2 11.9 07/15/2006 22:10:00 1.9 0.4 2.6 1.1 1.4 0.5 2.3 0.4 1.9 0.3 2.6 1.1 168 4 162 165 12.1 0 12.2 11.9 07/15/2006 22:20:00 1.7 0.4 2.6 0.4 1.3 0.5 2.6 0.4 1.7 0.3 2.6 0.7 173 11 171 165 12.1 0 12.5 11.9 07/15/2006 22:30:00 1.6 0.4 2.6 0.7 1.1 0.5 2.3 0.4 1.7 0.3 2.3 1.1 185 6 187 165 12.2 0 12.5 11.9 07/15/2006 22:40:00 1.1 0.3 1.5 0.4 0.5 0.2 1.1 0.4 1.1 0.3 1.9 0.4 195 3 191 165 12.3 0 12.5 11.9 07/15/2006 22:50:00 1.5 0.3 1.9 0.7 1 0.4 1.9 0.4 1.5 0.3 1.9 0.7 186 10 197 165 12.2 0 12.5 11.9 07/15/2006 23:00:00 1.7 0.3 2.3 0.7 1.2 0.5 2.3 0.4 1.8 0.3 2.3 1.1 171 4 173 165 12.1 0 12.2 11.9 07/15/2006 23:10:00 1.8 0.3 2.3 1.1 1.5 0.3 2.3 0.7 1.8 0.2 2.3 1.1 182 3 177 165 12.1 0 12.2 11.9 07/15/2006 23:20:00 1.7 0.3 2.3 0.7 1.4 0.3 2.3 0.4 1.7 0.2 2.3 1.1 186 5 180 165 12.1 0 12.2 11.9 07/15/2006 23:30:00 1.9 0.3 2.6 1.1 1.7 0.3 2.3 0.7 1.8 0.3 2.6 1.1 192 2 194 165 12.1 0 12.5 11.9 07/15/2006 23:40:00 1.2 0.3 1.9 0.4 0.8 0.4 1.5 0.4 1.2 0.4 1.9 0.4 179 8 190 165 12.1 0 12.5 11.9 07/15/2006 23:50:00 1.3 0.4 2.3 0.7 0.8 0.5 2.3 0.4 1.4 0.4 2.3 0.4 168 4 162 165 12 0 12.2 11.7 07/16/2006 00:00:00 1.8 0.3 2.6 1.1 1.6 0.3 2.3 0.7 1.8 0.2 2.3 1.1 167 4 169 165 11.8 0.1 12.2 11.7 07/16/2006 00:10:00 1.4 0.3 1.9 0.7 1.1 0.4 1.9 0.4 1.6 0.3 2.3 1.1 170 3 170 165 11.7 0.1 12.2 11.4 07/16/2006 00:20:00 1.3 0.3 1.9 0.4 0.9 0.4 1.9 0.4 1.6 0.3 2.3 0.7 155 7 164 165 11.6 0 11.9 11.1 07/16/2006 00:30:00 1.3 0.3 1.9 0.4 1 0.4 1.9 0.4 1.6 0.3 2.3 1.1 156 6 162 165 11.3 0.1 11.7 10.9 07/16/2006 00:40:00 0.9 0.3 1.5 0.4 0.4 0.2 1.1 0.4 0.9 0.3 1.5 0.4 164 0 165 165 11.3 0 11.7 10.9 07/16/2006 00:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0.2 1.1 0.4 165 0 165 165 11.3 0 11.7 11.1 07/16/2006 01:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0.1 0.7 0.4 165 0 165 165 11.3 0.1 11.4 10.9 07/16/2006 01:10:00 0.6 0.3 1.5 0.4 0.4 0 0.4 0.4 0.9 0.2 1.5 0.4 295 102 15 165 11.1 0.1 11.4 10.9 07/16/2006 01:20:00 1 0.2 1.5 0.4 0.4 0.2 1.1 0.4 1.4 0.2 1.9 1.1 23 5 25 165 11.1 0.2 11.4 10.9 07/16/2006 01:30:00 1 0.3 1.5 0.4 0.4 0.2 1.1 0.4 1.2 0.2 1.9 0.7 35 13 29 165 11.1 0.1 11.4 10.9 07/16/2006 01:40:00 1.8 0.3 2.3 0.7 1.2 0.5 2.3 0.4 2 0.4 2.6 1.1 21 7 7 165 10.9 0.1 11.4 10.6 07/16/2006 01:50:00 1.9 0.2 2.3 1.5 1.6 0.2 2.3 1.1 2.2 0.2 2.6 1.9 24 2 32 165 10.7 0.2 11.4 10.3 07/16/2006 02:00:00 1.8 0.3 2.3 1.1 1.4 0.6 2.3 0.4 2.3 0.2 2.6 1.9 20 4 23 165 10.5 0.3 10.9 10.1 07/16/2006 02:10:00 2.1 0.3 3 1.1 1.8 0.4 2.6 0.7 2.4 0.3 3 1.9 21 4 24 165 10.7 0.2 10.9 10.1 07/16/2006 02:20:00 1.9 0.2 2.3 1.5 1.4 0.3 2.3 0.7 2 0.2 2.6 1.5 17 4 16 165 10.5 0 10.9 10.1 07/16/2006 02:30:00 1.7 0.2 2.3 1.1 1.1 0.4 1.9 0.4 1.8 0.2 2.3 1.5 12 3 16 165 10.4 0 10.9 9.8 07/16/2006 02:40:00 1.9 0.2 2.3 1.5 1.7 0.3 2.3 0.7 1.9 0.3 2.6 1.1 27 10 8 165 10.4 0 10.9 10.3 07/16/2006 02:50:00 1.6 0.3 2.3 1.1 1.4 0.3 2.3 0.7 1.8 0.3 2.3 1.1 46 9 41 165 10.5 0 11.1 9.8 07/16/2006 03:00:00 1.2 0.3 1.9 0.4 0.9 0.4 1.5 0.4 1.5 0.2 1.9 1.1 55 9 50 165 10.6 0 10.9 10.3 07/16/2006 03:10:00 1.1 0.4 1.9 0.4 0.9 0.4 1.5 0.4 1.5 0.3 1.9 0.7 41 1 41 165 10.7 0 10.9 10.6 07/16/2006 03:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.6 0.3 1.1 0.4 53 9 165 165 10.7 0 10.9 10.6 07/16/2006 03:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.6 0.3 1.1 0.4 59 0 165 165 10.7 0 11.1 10.6 07/16/2006 03:40:00 0.4 0 0.7 0.4 0.4 0 0.4 0.4 0.7 0.3 1.5 0.4 72 12 59 165 10.8 0 11.1 10.9 07/16/2006 03:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0.2 1.1 0.4 90 0 165 165 10.8 0 11.1 10.9 07/16/2006 04:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.5 0.3 1.5 0.4 90 0 165 165 10.7 0 11.1 10.6 07/16/2006 04:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0.1 0.7 0.4 90 0 165 165 10.6 0 10.9 10.3 07/16/2006 04:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 90 0 165 165 10.5 0 10.9 10.3 07/16/2006 04:30:00 1 0.5 2.3 0.4 0.8 0.5 1.9 0.4 1.2 0.5 2.3 0.4 110 15 125 165 10.4 0 10.6 10.3 07/16/2006 04:40:00 2.5 0.4 3.4 1.5 2.5 0.4 3.4 1.5 2.6 0.4 3.4 1.9 127 11 146 165 10.4 0 10.6 10.3 07/16/2006 04:50:00 3.1 0.5 4.6 1.9 3 0.5 4.9 1.9 3.2 0.4 4.6 2.3 144 8 149 165 10.3 0 10.6 10.3 07/16/2006 05:00:00 3.9 0.5 4.9 2.3 3.8 0.4 5.3 2.6 4 0.5 5.3 2.3 155 11 153 165 10.2 0 10.6 9.8 07/16/2006 05:10:00 4 0.5 5.7 2.6 3.8 0.5 5.3 2.3 4.1 0.5 5.3 3 159 7 157 165 10.1 0 10.3 9.8 07/16/2006 05:20:00 4.2 0.6 5.7 2.6 4 0.5 5.3 2.6 4.2 0.5 5.3 2.6 163 6 168 165 10.1 0 10.3 9.8 07/16/2006 05:30:00 4.6 0.6 6.1 3 4.4 0.5 5.7 2.6 4.5 0.5 5.7 3 167 9 174 165 10.1 0 10.6 9.8 07/16/2006 05:40:00 5.4 0.5 6.5 3.8 5.2 0.4 6.5 4.2 5.6 0.5 6.8 4.6 170 6 171 165 10.1 0.1 10.6 9.6 07/16/2006 05:50:00 6.1 0.5 6.8 4.6 5.8 0.4 6.5 4.6 6.1 0.5 6.8 4.2 168 3 165 165 10.1 0 10.3 9.6 07/16/2006 06:00:00 5.4 0.5 6.5 4.2 5.2 0.4 6.1 4.2 5.4 0.4 6.5 4.2 170 7 169 165 10 0 10.3 9.6 07/16/2006 06:10:00 5.7 0.6 7.2 4.2 5.5 0.5 6.8 4.2 5.8 0.5 6.8 4.6 162 5 164 165 10 0 10.3 9.6 07/16/2006 06:20:00 6.2 0.8 7.6 4.2 6 0.7 7.2 4.2 6.2 0.7 7.6 4.6 162 7 167 165 9.9 0 10.1 9.6 07/16/2006 06:30:00 6.9 0.7 8.4 4.6 6.7 0.6 8 4.6 6.9 0.8 8.4 4.9 164 12 163 165 9.7 0 10.1 9.3 07/16/2006 06:40:00 6.5 0.5 8 5.3 6.3 0.5 7.6 4.9 6.5 0.5 8 4.9 164 10 165 165 9.6 0 9.8 9.3 07/16/2006 06:50:00 5.5 0.5 6.5 4.2 5.4 0.5 6.8 4.6 5.7 0.5 6.8 4.6 160 15 164 165 9.7 0 9.8 9.3 07/16/2006 07:00:00 5.7 0.6 7.2 3.4 5.5 0.6 6.8 3.4 5.8 0.6 7.2 4.2 161 7 162 165 9.8 0 10.1 9.3 07/16/2006 07:10:00 5.4 0.6 6.8 3.8 5.3 0.6 6.8 3.4 5.5 0.6 7.2 4.2 160 7 164 165 9.8 0 10.1 9.6 07/16/2006 07:20:00 4.6 0.6 6.5 3.4 4.5 0.6 6.5 3.4 4.7 0.6 6.8 3.4 164 6 165 165 10 0 10.3 9.6 07/16/2006 07:30:00 4.9 0.4 6.1 4.2 4.7 0.4 5.7 3.8 4.9 0.4 6.1 3.8 169 5 172 165 10.1 0.1 10.3 9.6 07/16/2006 07:40:00 5 0.4 6.1 3.8 4.9 0.3 5.7 3.8 5.2 0.4 6.1 4.2 162 4 170 165 10.1 0.1 10.6 9.6 07/16/2006 07:50:00 5.3 0.6 6.8 3.8 5.1 0.6 6.5 3.8 5.4 0.6 6.8 3.8 163 7 165 165 10 0.1 10.3 9.6 07/16/2006 08:00:00 5.1 0.6 6.8 3.4 5 0.5 6.5 3.8 5.3 0.5 6.8 4.2 162 5 164 165 10 0 10.3 9.6 07/16/2006 08:10:00 5.3 0.7 7.2 3.4 5.2 0.6 6.8 3.4 5.4 0.6 7.2 3.8 163 8 220 165 10 0.1 10.3 9.6 07/16/2006 08:20:00 4.9 0.7 6.5 3.4 4.7 0.7 6.5 3 5 0.6 6.5 3.8 163 7 166 165 10 0.1 10.3 9.6 07/16/2006 08:30:00 5.2 0.4 6.1 3.8 5 0.4 5.7 3.8 5.2 0.3 6.1 4.2 168 4 169 165 10.1 0.1 10.3 9.6 07/16/2006 08:40:00 5 0.5 6.1 3.8 4.9 0.4 5.7 3.8 5 0.4 6.1 3.8 167 4 170 165 10.1 0.1 10.3 9.8 07/16/2006 08:50:00 4.7 0.5 6.5 3.4 4.6 0.4 6.1 3.4 4.9 0.5 6.1 3.8 163 6 165 165 10.1 0 10.6 9.8 07/16/2006 09:00:00 4.3 0.5 5.3 2.6 4.3 0.5 5.3 3 4.4 0.5 5.3 3 164 11 176 165 10.2 0 10.6 9.8 07/16/2006 09:10:00 4.3 0.5 5.3 3 4.2 0.5 4.9 3 4.4 0.5 5.3 3.4 164 3 169 165 10.3 0 10.6 10.1 07/16/2006 09:20:00 4 0.5 4.9 2.3 4 0.5 4.9 2.3 4.2 0.5 5.3 2.6 166 4 172 165 10.4 0 10.6 10.3 07/16/2006 09:30:00 4.4 0.5 5.7 3 4.4 0.5 5.7 3 4.7 0.5 6.1 3 163 7 160 165 10.4 0 10.9 10.3 07/16/2006 09:40:00 4.8 0.6 6.1 2.6 4.8 0.5 6.1 2.3 4.9 0.5 6.1 3.8 161 6 161 165 10.6 0.1 11.1 10.3 07/16/2006 09:50:00 4.9 0.5 6.5 3.8 4.8 0.5 6.5 3.4 5.1 0.5 6.5 4.2 168 6 171 165 10.7 0 10.9 10.6 07/16/2006 10:00:00 4.6 0.5 5.7 3.4 4.5 0.5 6.1 3.4 4.8 0.5 6.1 3.4 170 4 172 165 10.7 0.1 10.9 10.3 07/16/2006 10:10:00 5 0.4 6.1 3.8 4.9 0.4 6.1 4.2 5.2 0.4 6.5 4.2 172 5 166 165 10.7 0.1 10.9 10.1 07/16/2006 10:20:00 5.1 0.4 6.1 4.2 5 0.3 5.7 4.2 5.3 0.4 6.1 3.8 176 5 175 165 10.7 0.1 10.9 10.1 07/16/2006 10:30:00 4.5 0.5 5.7 3.4 4.4 0.4 5.7 3 4.8 0.4 5.7 3.4 172 5 176 165 10.7 0.1 11.4 10.3 07/16/2006 10:40:00 4.8 0.4 5.7 4.2 4.7 0.3 5.7 3.8 5 0.4 6.1 4.2 169 4 164 165 10.7 0.2 11.1 10.3 07/16/2006 10:50:00 4.7 0.4 5.7 3.4 4.6 0.4 6.1 3.8 4.8 0.4 6.1 3.8 168 4 161 165 10.8 0.2 11.1 10.3 07/16/2006 11:00:00 5 0.3 5.7 4.2 4.8 0.3 5.7 4.2 5.1 0.3 6.1 4.6 168 12 164 165 10.7 0.1 11.1 10.3 07/16/2006 11:10:00 4.8 0.3 5.7 3.8 4.6 0.3 5.3 3.8 5 0.3 5.7 4.2 167 4 162 165 10.9 0 11.1 10.6 07/16/2006 11:20:00 4.6 0.3 5.3 3.8 4.5 0.3 5.3 3.8 4.8 0.3 5.7 4.2 154 7 160 165 11.1 0.2 11.4 10.6 07/16/2006 11:30:00 5.2 0.4 6.1 3.8 5.1 0.4 6.1 3.8 5.3 0.4 6.1 4.2 154 4 157 165 11.2 0.1 11.7 10.9 07/16/2006 11:40:00 5.2 0.3 6.1 4.2 5 0.3 5.7 4.6 5.3 0.3 6.1 3.8 155 3 156 165 11.5 0 11.7 11.1 07/16/2006 11:50:00 5.2 0.3 6.5 4.2 5.1 0.3 6.5 4.6 5.4 0.3 6.5 4.6 148 10 126 165 11.5 0 11.7 11.4 07/16/2006 12:00:00 5.1 0.4 6.1 4.2 5.1 0.4 6.1 4.2 5 0.4 6.1 3.8 132 7 120 165 11.2 0.1 11.7 10.6 07/16/2006 12:10:00 5.4 0.6 6.8 3.8 5.4 0.7 7.2 3.8 5.5 0.6 7.6 3.8 139 8 128 165 11.3 0.1 11.7 10.9 07/16/2006 12:20:00 5.8 0.4 6.8 4.2 5.8 0.5 6.8 4.2 5.8 0.5 6.8 4.2 132 5 130 165 10.5 0 11.1 10.3 07/16/2006 12:30:00 5.6 0.4 6.5 4.6 5.6 0.4 6.8 4.6 5.5 0.5 6.8 3.8 133 5 129 165 10.4 0 10.6 10.3 07/16/2006 12:40:00 5.6 0.5 7.2 4.2 5.7 0.5 6.8 4.2 5.5 0.6 6.8 3.8 131 5 129 165 10.4 0 10.6 10.3 07/16/2006 12:50:00 6 0.7 7.6 4.2 6 0.7 7.6 3.8 5.9 0.7 7.2 4.2 131 6 123 165 10.3 0 10.6 10.1 07/16/2006 13:00:00 6.5 0.6 8 4.9 6.6 0.6 8 4.9 6.4 0.6 8 4.9 124 5 124 165 10.2 0.1 10.6 9.8 07/16/2006 13:10:00 6.1 0.5 7.6 4.9 6.2 0.5 7.2 4.2 5.9 0.6 7.2 3.4 129 5 131 165 10.3 0.1 10.6 9.8 07/16/2006 13:20:00 5.3 0.6 6.8 4.2 5.4 0.6 6.8 3.8 5.2 0.6 6.8 3.4 129 7 129 165 10.3 0.1 10.9 9.8 07/16/2006 13:30:00 4.7 0.4 6.1 3.4 4.8 0.4 5.7 3.8 4.6 0.4 5.7 3.4 127 5 127 165 10.3 0.1 10.9 9.8 07/16/2006 13:40:00 5.1 0.5 6.5 3.8 5.2 0.5 6.5 3.4 5 0.5 6.5 3.4 126 6 121 165 10.3 0.1 10.9 9.8 07/16/2006 13:50:00 6.1 0.4 7.2 4.6 6.2 0.5 7.2 4.6 6 0.5 6.8 4.6 125 5 125 165 10.3 0.1 10.9 9.8 07/16/2006 14:00:00 5.8 0.6 7.2 3.8 5.9 0.7 7.2 3.8 5.7 0.7 7.6 3.4 125 6 125 165 10.1 0.2 10.6 9.6 07/16/2006 14:10:00 5.9 0.5 7.2 4.2 6 0.6 7.6 4.2 5.8 0.6 7.2 3.8 126 8 116 165 10.1 0.2 10.3 9.6 07/16/2006 14:20:00 5.7 0.5 7.2 4.2 5.8 0.6 7.6 4.6 5.7 0.5 6.8 4.2 127 6 116 165 10.1 0.2 10.3 9.6 07/16/2006 14:30:00 6 0.5 7.6 4.6 6.1 0.5 7.6 4.9 5.9 0.5 7.2 4.2 126 5 127 165 10 0.2 10.3 9.6 07/16/2006 14:40:00 5.9 0.5 7.2 4.6 6 0.5 7.2 4.9 5.9 0.5 7.2 4.2 129 6 122 165 10.1 0.1 10.6 9.8 07/16/2006 14:50:00 5.8 0.5 7.2 4.9 5.9 0.5 7.2 4.9 5.7 0.5 7.2 4.2 133 5 134 165 10.1 0.1 10.9 9.8 07/16/2006 15:00:00 5 0.6 6.5 3.4 5.1 0.6 6.5 3.8 4.9 0.6 6.5 3.4 135 8 139 165 10.3 0.2 10.9 9.8 07/16/2006 15:10:00 4.7 0.5 6.1 3.4 4.8 0.5 6.1 3.4 4.7 0.4 5.7 3.4 136 7 141 165 10.5 0.2 11.1 10.3 07/16/2006 15:20:00 4.5 0.5 5.7 3.4 4.6 0.5 5.7 3.4 4.5 0.4 5.3 2.6 134 6 123 165 10.6 0.1 10.9 10.3 07/16/2006 15:30:00 4.2 0.5 5.7 2.6 4.3 0.5 5.7 2.6 4.3 0.5 5.7 3 135 6 136 165 10.5 0.1 10.9 10.3 07/16/2006 15:40:00 4.4 0.5 5.7 3.4 4.5 0.5 6.1 3.4 4.4 0.5 5.3 3 130 6 128 165 10.2 0.1 10.9 9.8 07/16/2006 15:50:00 4.2 0.4 5.3 3 4.2 0.4 5.3 3 4.1 0.4 5.3 3 127 6 122 165 10.1 0.2 10.6 9.6 07/16/2006 16:00:00 4.1 0.5 5.3 2.6 4.2 0.5 5.3 2.6 3.9 0.5 5.3 2.6 128 6 121 165 10.1 0.1 10.6 9.8 07/16/2006 16:10:00 4.5 0.6 6.1 2.3 4.6 0.7 6.1 2.3 4.5 0.6 5.7 3 125 5 118 165 10 0.2 10.9 9.6 07/16/2006 16:20:00 4.6 0.4 6.1 3.4 4.6 0.4 5.7 3.4 4.5 0.5 5.7 3.4 127 6 138 165 10 0.2 10.3 9.6 07/16/2006 16:30:00 4.6 0.5 6.1 3.4 4.6 0.5 6.1 3 4.4 0.5 5.7 3 125 8 113 165 10.1 0.2 10.6 9.6 07/16/2006 16:40:00 4.5 0.4 5.7 3.4 4.6 0.5 6.1 3.4 4.4 0.5 6.1 3 128 6 120 165 10.1 0.2 10.9 9.6 07/16/2006 16:50:00 4.9 0.5 6.1 3.8 5 0.5 6.5 3.8 4.9 0.5 6.1 3.8 130 5 129 165 10.1 0.2 10.3 9.6 07/16/2006 17:00:00 5.1 0.6 6.8 3.8 5.1 0.5 6.8 3.8 4.9 0.5 6.5 3.8 131 6 136 165 10.1 0.2 10.3 9.6 07/16/2006 17:10:00 5 0.5 6.1 3.4 5.1 0.5 6.5 3 4.9 0.5 6.1 3 132 5 144 165 10.1 0.1 10.3 9.8 07/16/2006 17:20:00 4.9 0.6 6.5 3.4 5 0.6 6.5 3.4 4.7 0.6 6.5 3 134 6 142 165 10.1 0.2 10.3 9.6 07/16/2006 17:30:00 4.1 0.7 5.7 2.3 4.2 0.7 5.7 2.3 4 0.6 5.7 2.6 133 7 137 165 10.1 0.2 10.3 9.6 07/16/2006 17:40:00 4 0.4 4.9 2.6 4.1 0.5 5.3 2.6 3.9 0.5 5.3 2.3 128 6 145 165 10.1 0 10.9 9.6 07/16/2006 17:50:00 3.8 0.4 4.9 2.3 3.9 0.5 4.9 1.9 3.7 0.4 4.9 2.3 132 8 133 165 10.1 0 10.3 9.6 07/16/2006 18:00:00 3.9 0.5 4.9 2.6 4 0.6 4.9 2.6 3.8 0.6 5.3 2.3 134 8 148 165 10.2 0 10.6 10.1 07/16/2006 18:10:00 3.2 0.6 4.6 1.5 3.2 0.6 4.9 1.1 3 0.5 4.9 1.9 134 8 127 165 10.3 0 10.6 10.3 07/16/2006 18:20:00 3.5 0.5 4.9 2.3 3.7 0.6 4.9 2.3 3.3 0.6 4.6 1.9 132 8 135 165 10.3 0 10.6 10.3 07/16/2006 18:30:00 3.8 0.4 4.6 2.6 3.9 0.4 4.9 2.6 3.7 0.4 4.6 2.6 125 7 122 165 10.1 0 10.9 9.8 07/16/2006 18:40:00 4 0.5 5.7 2.6 4.1 0.5 5.7 3 3.9 0.5 5.7 2.6 136 10 151 165 10.1 0 10.9 9.8 07/16/2006 18:50:00 3.6 0.6 4.9 1.9 3.7 0.6 4.9 2.3 3.7 0.6 5.3 2.3 144 12 138 165 10.1 0 10.3 9.8 07/16/2006 19:00:00 3.7 0.6 5.3 2.3 3.8 0.6 5.3 2.3 3.8 0.8 5.7 2.3 149 12 145 165 10.2 0 10.6 10.1 07/16/2006 19:10:00 3.9 0.9 6.1 1.5 3.9 0.9 6.1 1.9 4 0.9 6.1 1.5 154 16 159 165 10.3 0 10.6 10.1 07/16/2006 19:20:00 4.5 1.2 7.2 2.3 4.5 1.1 6.8 2.3 4.7 1.1 7.6 2.3 153 14 145 165 10.2 0 10.3 10.1 07/16/2006 19:30:00 6.3 0.8 7.6 3.8 6.1 0.7 7.2 3.4 6.3 0.6 7.6 4.6 165 4 164 165 10.2 0 10.6 10.1 07/16/2006 19:40:00 6.4 0.6 7.6 4.9 6.3 0.6 7.6 4.6 6.4 0.7 8 4.6 162 5 173 165 10.1 0 10.3 9.8 07/16/2006 19:50:00 6.5 0.7 8.4 4.2 6.4 0.6 8 4.6 6.6 0.7 8 4.6 164 8 169 165 10.1 0 10.3 9.8 07/16/2006 20:00:00 6.7 0.5 7.6 5.3 6.4 0.4 7.2 4.9 6.7 0.5 8 5.3 164 10 165 165 10.1 0 10.3 9.8 07/16/2006 20:10:00 5.9 0.7 7.2 3.8 5.7 0.6 6.8 3.8 6 0.7 7.6 4.2 167 4 166 165 10.1 0 10.3 9.6 07/16/2006 20:20:00 5.9 0.6 7.2 4.2 5.6 0.5 6.8 4.2 5.7 0.6 7.2 4.2 169 12 179 165 10 0 10.3 9.6 07/16/2006 20:30:00 6.2 0.4 7.2 4.9 6 0.4 6.8 4.9 6.2 0.5 7.2 4.9 170 5 165 165 10 0 10.3 9.6 07/16/2006 20:40:00 6.3 0.6 7.2 4.2 6.1 0.5 6.8 4.2 6.3 0.6 7.2 4.6 170 5 172 165 10.1 0 10.3 9.6 07/16/2006 20:50:00 6.5 0.6 8 5.3 6.3 0.5 7.6 4.9 6.4 0.6 8 4.9 166 5 172 165 10 0 10.3 9.6 07/16/2006 21:00:00 7.4 0.5 8.8 5.7 7.2 0.5 8.4 5.7 7.3 0.6 8.8 5.7 165 14 170 165 10 0 10.3 9.6 07/16/2006 21:10:00 6.7 0.7 8.4 4.2 6.5 0.7 8 4.2 6.8 0.7 8.4 5.3 162 6 165 165 10 0 10.3 9.6 07/16/2006 21:20:00 7.2 1.3 9.9 4.6 7 1.2 9.5 4.6 7.4 1.1 9.9 5.3 160 9 164 165 9.9 0 10.1 9.6 07/16/2006 21:30:00 7.7 0.8 9.5 6.1 7.6 0.7 9.1 6.1 7.9 0.8 9.5 5.7 162 9 165 165 9.9 0 10.3 9.6 07/16/2006 21:40:00 7.6 0.7 9.5 5.3 7.3 0.7 9.5 4.9 7.7 0.6 9.5 5.7 160 12 163 165 9.8 0.1 10.3 9.3 07/16/2006 21:50:00 8.3 0.7 10.3 6.5 8.1 0.7 9.5 6.1 8.3 0.7 10.3 6.8 157 8 164 165 9.6 0.1 10.1 9 07/16/2006 22:00:00 7.4 0.7 9.1 5.3 7.2 0.7 9.1 5.3 7.4 0.7 9.5 5.3 157 9 162 165 9.5 0.2 9.8 9 07/16/2006 22:10:00 6.5 0.7 8.8 4.9 6.4 0.7 8.8 4.6 6.5 0.7 8.8 4.6 157 7 152 165 9.6 0.2 9.8 9 07/16/2006 22:20:00 6.4 0.8 8.4 4.6 6.2 0.7 8 4.6 6.5 0.8 8.4 4.6 157 8 159 165 9.7 0.1 9.8 9 07/16/2006 22:30:00 5 0.7 6.8 3 5 0.7 6.8 3 5.2 0.6 6.8 3 156 8 139 165 9.6 0.2 10.3 9 07/16/2006 22:40:00 5.1 0.7 7.6 3.4 5.1 0.7 7.2 3.4 5.4 0.7 7.2 4.2 159 8 162 165 9.6 0.2 10.1 9 07/16/2006 22:50:00 4.9 0.7 6.8 3.4 4.9 0.7 6.8 3.4 5.1 0.7 6.8 3.8 159 9 293 165 9.6 0.2 9.8 9 07/16/2006 23:00:00 4.2 0.5 5.3 2.6 4.2 0.5 4.9 3 4.3 0.5 5.3 2.6 153 5 160 165 9.4 0.2 9.6 8.8 07/16/2006 23:10:00 3 0.5 4.9 1.9 3.1 0.4 4.9 1.9 3.2 0.4 4.6 2.3 150 8 161 165 9.4 0.2 9.6 8.8 07/16/2006 23:20:00 3.3 0.7 4.6 1.9 3.3 0.6 4.6 1.9 3.6 0.6 4.9 2.3 151 8 153 165 9.4 0.1 9.6 8.8 07/16/2006 23:30:00 3.7 0.4 4.9 2.6 3.7 0.4 4.6 2.6 3.8 0.4 4.6 2.6 154 7 154 165 9.4 0 9.6 8.8 07/16/2006 23:40:00 3.8 0.6 5.7 1.9 3.8 0.6 5.3 1.9 4.1 0.5 5.3 3 156 6 163 165 9.4 0 9.6 9 07/16/2006 23:50:00 4.7 0.6 5.7 3.4 4.7 0.5 5.7 3.4 4.9 0.6 6.1 3.4 154 4 151 165 9.6 0.1 9.8 9 07/17/2006 00:00:00 3.7 0.5 4.9 2.6 3.8 0.5 4.9 3 3.9 0.4 4.9 3 149 5 151 165 9.6 0.1 9.8 9 07/17/2006 00:10:00 3.9 0.5 4.9 2.6 4 0.5 4.9 2.6 3.9 0.6 4.9 2.6 145 7 149 165 9.6 0.1 9.6 9 07/17/2006 00:20:00 4.8 0.3 5.7 3.8 4.9 0.3 5.7 3.8 4.8 0.3 5.7 4.2 142 3 144 165 9.6 0.2 9.6 8.8 07/17/2006 00:30:00 3.8 0.3 4.6 3 3.9 0.3 4.6 3.4 3.8 0.5 4.9 2.6 135 4 145 165 9.6 0.2 9.8 8.8 07/17/2006 00:40:00 3.8 0.3 4.6 3 3.9 0.3 4.6 3 3.7 0.4 4.6 2.3 140 4 143 165 9.6 0.1 9.8 9 07/17/2006 00:50:00 4.4 0.4 5.3 3.4 4.5 0.4 5.3 3.8 4.5 0.4 5.3 3.8 135 4 137 165 9.6 0.1 9.8 9 07/17/2006 01:00:00 5.7 0.5 6.8 4.6 5.7 0.5 6.8 4.6 5.7 0.5 6.8 4.2 140 5 142 165 9.7 0 9.8 9 07/17/2006 01:10:00 5.7 0.5 6.8 4.6 5.7 0.5 6.8 4.9 5.7 0.5 7.2 4.2 141 6 141 165 9.8 0 9.8 9.3 07/17/2006 01:20:00 6.2 0.5 7.6 4.9 6.2 0.5 7.6 4.9 6.1 0.5 7.6 4.6 142 5 148 165 9.8 0 9.8 9.3 07/17/2006 01:30:00 6.8 0.7 8.4 5.3 6.8 0.7 8 4.9 6.7 0.7 8.4 4.9 146 5 131 165 9.7 0 10.1 9.3 07/17/2006 01:40:00 6.5 0.6 7.6 4.6 6.5 0.6 7.6 4.2 6.4 0.6 7.6 4.6 144 5 149 165 9.7 0 10.1 9.3 07/17/2006 01:50:00 7.1 0.5 8.4 5.7 7.1 0.5 8.4 5.7 7.1 0.5 8.8 5.7 145 5 146 165 9.6 0.1 9.8 9.3 07/17/2006 02:00:00 7.8 0.7 9.5 6.1 7.8 0.7 9.5 6.1 7.7 0.7 9.1 5.7 144 4 145 165 9.6 0.1 9.8 9.3 07/17/2006 02:10:00 8.1 0.6 9.5 6.5 8.1 0.6 9.5 6.5 8 0.6 9.5 6.1 144 5 140 165 9.6 0 9.8 9.3 07/17/2006 02:20:00 8.6 0.6 9.9 7.2 8.5 0.6 9.9 7.2 8.5 0.6 9.9 6.5 148 3 143 165 9.6 0.1 9.8 9 07/17/2006 02:30:00 8.2 0.5 9.1 7.2 8.2 0.5 9.1 7.2 8.2 0.5 9.5 6.8 148 3 153 165 9.5 0.1 10.1 9 07/17/2006 02:40:00 7.7 0.3 8.4 6.5 7.6 0.3 8.4 6.8 7.6 0.4 8.4 6.5 148 2 149 165 9.4 0 9.8 8.8 07/17/2006 02:50:00 7.5 0.5 8.8 6.1 7.5 0.5 8.8 6.1 7.4 0.5 8.8 5.7 146 3 145 165 9.3 0 9.6 8.8 07/17/2006 03:00:00 7.7 0.4 8.4 6.5 7.7 0.4 8.4 6.5 7.5 0.5 8.8 5.7 145 3 145 165 9.2 0 9.3 9 07/17/2006 03:10:00 7.5 0.5 8.4 5.7 7.5 0.5 8.4 5.7 7.4 0.5 8.8 5.7 146 3 145 165 9.1 0 9.3 9 07/17/2006 03:20:00 7.4 0.4 8 6.1 7.3 0.4 8 6.1 7.3 0.4 8 6.1 146 3 144 165 9 0 9.3 9 07/17/2006 03:30:00 6.9 0.4 8 5.7 6.9 0.4 8 5.7 6.8 0.5 8 5.3 145 3 145 165 9 0 9 8.8 07/17/2006 03:40:00 6.7 0.3 7.2 5.7 6.7 0.3 7.2 5.7 6.6 0.3 7.2 5.7 147 3 147 165 8.9 0 9 8.5 07/17/2006 03:50:00 6.3 0.3 7.2 5.3 6.3 0.3 6.8 5.3 6.2 0.3 7.2 5.3 146 3 148 165 8.9 0 9.3 8.8 07/17/2006 04:00:00 5.8 0.3 6.5 4.6 5.8 0.3 6.5 4.9 5.8 0.3 6.8 4.9 146 4 149 165 9 0 9 8.8 07/17/2006 04:10:00 5.6 0.3 6.5 4.6 5.6 0.3 6.5 4.9 5.6 0.4 6.5 4.6 142 4 141 165 9.1 0 9.3 9 07/17/2006 04:20:00 5.6 0.4 6.5 4.6 5.6 0.3 6.5 4.9 5.6 0.4 6.5 4.6 142 5 144 165 9.1 0 9.3 9 07/17/2006 04:30:00 6.1 0.7 7.6 4.6 6 0.7 7.6 4.6 6 0.8 7.6 4.2 136 8 133 165 9.1 0 9.3 9 07/17/2006 04:40:00 6.1 0.7 8.4 4.2 6 0.7 8.4 4.2 6 0.9 9.1 3.4 137 8 135 165 9.1 0 9.3 9 07/17/2006 04:50:00 7.2 0.7 8.8 5.3 7.1 0.7 8.8 4.9 7.2 0.6 8.4 5.3 139 9 138 165 9 0 9.3 9 07/17/2006 05:00:00 6.5 0.6 7.6 4.9 6.3 0.6 7.6 4.2 6.4 0.6 8 4.9 143 6 146 165 9 0 9.3 9 07/17/2006 05:10:00 6.3 0.6 7.6 4.6 6.2 0.6 7.6 4.6 6 0.6 7.6 3.8 134 7 132 165 9 0 9.6 9 07/17/2006 05:20:00 6.7 0.7 8.8 4.9 6.7 0.7 8.4 4.9 6.5 0.6 8.4 4.9 132 6 135 165 9.1 0 9.3 9 07/17/2006 05:30:00 6.8 0.6 8.8 4.9 6.8 0.6 8.8 5.3 6.5 0.7 8.4 4.6 127 6 139 165 9.2 0 9.3 9 07/17/2006 05:40:00 6.8 0.6 8.8 5.3 6.8 0.6 8.4 5.3 6.6 0.6 8.8 4.9 128 5 119 165 9.4 0 9.3 9.3 07/17/2006 05:50:00 7.4 0.8 9.5 5.7 7.4 0.8 9.5 5.3 7.1 0.8 9.1 4.9 131 6 136 165 9.4 0 9.6 9.3 07/17/2006 06:00:00 7.7 0.8 10.3 5.7 7.7 0.8 10.3 5.7 7.4 0.8 9.9 4.9 133 6 127 165 9.6 0 9.6 9.6 07/17/2006 06:10:00 8.3 0.7 9.9 6.1 8.3 0.8 10.7 6.5 8.1 0.8 9.9 5.7 133 7 129 165 9.6 0 10.3 9.6 07/17/2006 06:20:00 8.5 0.9 10.7 6.5 8.5 0.9 10.7 6.1 8.2 0.9 10.3 5.7 137 6 139 165 9.6 0 9.8 9.6 07/17/2006 06:30:00 8.6 0.7 10.3 6.5 8.7 0.7 10.3 6.8 8.5 0.7 10.3 6.5 137 6 135 165 9.8 0 9.8 9 07/17/2006 06:40:00 8.9 0.8 10.7 6.5 8.9 0.8 10.7 6.5 8.5 0.8 10.7 6.5 137 6 136 165 9.8 0 10.3 9 07/17/2006 06:50:00 9.6 0.8 11.8 7.6 9.6 0.8 11.8 8 9.3 0.9 11.8 7.2 136 7 140 165 9.8 0 9.8 9 07/17/2006 07:00:00 9.4 0.9 11.8 7.2 9.4 1 11.8 7.2 8.8 1.1 11.8 6.1 133 7 132 165 9.8 0 9.8 9 07/17/2006 07:10:00 9.3 0.8 11.1 6.8 9.4 0.8 11.1 6.8 9 0.9 11.5 6.5 132 6 136 165 9.8 0.1 9.8 9.3 07/17/2006 07:20:00 8.7 0.6 10.7 7.2 8.8 0.6 10.3 7.2 8.5 0.7 9.9 6.8 129 5 133 165 9.8 0 10.1 9.3 07/17/2006 07:30:00 8 0.8 9.5 5.7 8.1 0.9 9.9 5.7 7.8 0.9 9.9 5.3 135 7 137 165 9.9 0 10.3 9.6 07/17/2006 07:40:00 7.9 0.8 9.9 5.3 7.9 0.9 9.9 5.3 7.7 0.9 9.5 5.3 136 6 132 165 9.9 0 10.1 9.6 07/17/2006 07:50:00 7.9 0.9 9.5 4.9 7.8 0.9 9.5 5.3 7.6 1 9.9 5.3 138 6 146 165 10 0.1 10.1 9.6 07/17/2006 08:00:00 7.7 0.5 8.8 6.5 7.6 0.5 8.8 6.5 7.6 0.6 8.8 6.1 140 3 141 165 10 0.2 10.3 9.6 07/17/2006 08:10:00 7.2 0.5 8.4 5.7 7.2 0.5 8.8 5.7 7.1 0.6 8.8 5.7 139 5 142 165 10.1 0.2 10.3 9.6 07/17/2006 08:20:00 6.9 0.5 8 5.3 6.9 0.5 8 5.3 6.8 0.6 8.4 5.3 141 5 143 165 10 0.2 10.3 9.6 07/17/2006 08:30:00 6.7 0.4 8 5.7 6.8 0.4 8 5.7 6.6 0.5 8 4.9 140 4 144 165 10 0.2 10.3 9.6 07/17/2006 08:40:00 7.2 0.5 8.4 5.7 7.2 0.5 8.4 5.7 7 0.6 8.8 5.3 140 4 142 165 10.1 0.1 10.6 9.6 07/17/2006 08:50:00 7.4 0.5 8.4 6.1 7.4 0.5 8.4 6.1 7.2 0.5 8.4 5.7 141 5 141 165 10.1 0.1 10.6 9.6 07/17/2006 09:00:00 7.4 0.5 8.8 6.1 7.4 0.5 8.8 5.7 7.3 0.6 8.8 5.7 141 5 136 165 10.1 0.1 10.3 9.6 07/17/2006 09:10:00 7.7 0.5 9.1 6.1 7.7 0.5 9.1 6.1 7.5 0.6 9.1 5.7 141 5 136 165 10.2 0 10.3 9.8 07/17/2006 09:20:00 7.7 0.6 8.8 6.1 7.8 0.6 9.1 6.5 7.5 0.6 9.1 5.7 140 5 144 165 10.2 0 10.6 9.8 07/17/2006 09:30:00 7.5 0.6 9.1 5.7 7.5 0.6 8.8 5.7 7.3 0.7 9.1 5.3 142 6 145 165 10.3 0 10.6 9.8 07/17/2006 09:40:00 8.3 0.6 9.5 6.8 8.3 0.6 9.5 6.8 8.1 0.7 9.5 6.1 145 4 137 165 10.2 0 10.6 9.8 07/17/2006 09:50:00 8.4 0.7 9.9 6.5 8.4 0.7 10.3 6.5 8.3 0.7 10.3 6.5 143 6 145 165 10.1 0 10.3 9.8 07/17/2006 10:00:00 8.1 0.6 10.3 6.5 8.1 0.6 10.3 6.5 7.9 0.7 9.5 6.1 143 5 135 165 10.3 0 10.6 10.1 07/17/2006 10:10:00 8.3 0.5 9.5 6.8 8.3 0.5 9.5 7.2 8.2 0.5 10.3 6.8 145 5 154 165 10.4 0 10.6 9.8 07/17/2006 10:20:00 7.9 0.5 9.1 6.5 7.8 0.5 9.1 6.5 7.7 0.5 8.8 6.1 148 3 147 165 10.3 0 10.6 9.8 07/17/2006 10:30:00 7.3 0.4 8 6.5 7.2 0.4 8 6.5 7.1 0.5 8 5.3 145 3 148 165 10.2 0 10.9 9.8 07/17/2006 10:40:00 7.2 0.4 8 5.7 7.2 0.3 8 6.1 7 0.4 8 5.3 146 3 150 165 10.2 0 10.6 9.8 07/17/2006 10:50:00 6.9 0.4 8 5.3 7 0.5 8 5.7 6.7 0.5 7.6 4.6 143 4 151 165 10.2 0 10.6 9.8 07/17/2006 11:00:00 7.4 0.5 8.4 4.9 7.4 0.5 8.4 5.3 7.3 0.6 8.4 5.3 142 3 139 165 10.3 0 10.6 9.8 07/17/2006 11:10:00 7.1 0.7 8.8 5.3 7.1 0.7 8.4 5.3 6.9 0.7 8.4 5.3 142 3 141 165 10.3 0 10.6 9.8 07/17/2006 11:20:00 6.4 0.6 8.4 4.9 6.5 0.6 8.4 4.9 6.4 0.6 9.1 4.9 142 5 137 165 10.3 0 10.6 10.1 07/17/2006 11:30:00 7.2 0.8 9.1 5.3 7.2 0.8 8.8 4.9 7.1 0.8 8.8 5.3 142 6 142 165 10.3 0 10.6 10.1 07/17/2006 11:40:00 7.5 0.6 8.8 5.7 7.5 0.6 9.1 5.7 7.1 0.8 9.1 4.9 140 6 144 165 10.5 0.1 10.9 10.3 07/17/2006 11:50:00 7.5 0.8 9.5 5.3 7.5 0.8 9.5 5.3 7.1 1 9.5 4.6 135 9 143 165 10.4 0 10.9 10.1 07/17/2006 12:00:00 7.6 1 9.9 4.9 7.6 1 9.9 4.9 7.3 1 9.5 4.9 139 8 136 165 10.3 0 10.6 10.1 07/17/2006 12:10:00 8.6 0.7 10.7 5.7 8.6 0.8 11.1 5.7 8.1 0.9 10.3 5.7 137 7 138 165 10.4 0 10.9 10.1 07/17/2006 12:20:00 8.3 0.7 9.9 6.5 8.3 0.6 9.9 6.5 8.1 0.7 9.9 5.7 139 5 148 165 10.4 0 10.9 10.1 07/17/2006 12:30:00 7.1 0.6 8.4 5.3 7.1 0.6 8.4 4.9 6.8 0.7 8.4 4.9 140 6 144 165 10.4 0 10.6 10.3 07/17/2006 12:40:00 6.3 0.4 7.2 5.3 6.3 0.4 7.2 5.3 6.2 0.5 7.2 4.9 143 5 142 165 10.5 0.1 10.9 10.3 07/17/2006 12:50:00 6.3 0.3 7.2 5.7 6.3 0.3 7.2 5.3 6.3 0.4 7.2 4.9 145 4 148 165 10.5 0.1 10.9 10.3 07/17/2006 13:00:00 6.2 0.3 7.2 5.3 6.2 0.3 7.2 5.3 6.1 0.3 6.8 4.9 144 5 147 165 10.5 0 10.9 10.3 07/17/2006 13:10:00 6.5 0.5 7.6 5.3 6.4 0.5 7.6 4.9 6.4 0.5 7.6 4.9 150 5 145 165 10.5 0 10.9 10.3 07/17/2006 13:20:00 5.8 0.5 6.8 4.2 5.8 0.4 6.8 4.2 5.9 0.5 6.8 4.6 148 3 148 165 10.5 0 10.9 10.3 07/17/2006 13:30:00 6 0.6 7.2 4.2 6 0.6 7.2 4.2 5.9 0.6 6.8 4.2 141 4 140 165 10.6 0 10.9 10.3 07/17/2006 13:40:00 6.5 0.5 7.6 5.3 6.5 0.5 7.6 4.6 6.4 0.7 7.6 4.6 140 5 140 165 10.2 0 10.6 9.8 07/17/2006 13:50:00 6.3 0.5 7.6 4.9 6.3 0.5 7.6 4.9 6.2 0.6 7.6 4.6 143 5 141 165 10.1 0 10.3 9.6 07/17/2006 14:00:00 6.2 0.5 7.2 4.6 6.1 0.5 7.2 4.6 5.8 0.6 6.8 4.2 141 6 155 165 10.1 0 10.3 9.8 07/17/2006 14:10:00 6.4 0.4 7.2 4.9 6.4 0.4 7.2 4.6 6.1 0.6 7.6 4.2 142 5 141 165 10.1 0 10.3 9.8 07/17/2006 14:20:00 6.8 0.6 8.4 4.6 6.7 0.6 8.4 4.9 6.4 0.7 8 4.6 142 5 143 165 10.1 0 10.3 9.6 07/17/2006 14:30:00 6.9 0.5 8 5.3 6.8 0.5 8 5.3 6.5 0.6 8 4.9 140 5 139 165 10 0 10.3 9.6 07/17/2006 14:40:00 7.2 0.6 8.8 5.3 7.2 0.6 8.8 5.3 6.8 0.6 8.4 4.9 139 5 140 165 9.9 0 10.1 9.6 07/17/2006 14:50:00 8.3 0.8 9.9 4.9 8.3 0.8 9.9 4.9 7.9 1 9.5 4.6 143 5 144 165 10 0 10.1 9.6 07/17/2006 15:00:00 8.1 0.5 9.1 6.5 8 0.5 9.1 6.5 7.8 0.6 9.1 6.1 145 4 138 165 10 0 10.1 9.6 07/17/2006 15:10:00 6.9 0.6 8.4 5.7 6.9 0.6 8 5.7 6.7 0.5 8 4.9 142 5 140 165 10.1 0 10.3 9.8 07/17/2006 15:20:00 7 0.7 8.8 4.9 7 0.7 9.1 4.9 6.9 0.7 8.8 5.3 141 6 136 165 10.5 0 10.9 10.3 07/17/2006 15:30:00 7.3 0.5 8.4 6.1 7.3 0.5 8.4 6.1 7.2 0.5 8.4 6.1 139 4 136 165 10.4 0 10.6 10.3 07/17/2006 15:40:00 7.5 0.6 8.8 5.7 7.5 0.6 8.8 5.7 7.4 0.6 9.1 5.3 140 5 139 165 10.3 0 10.6 10.3 07/17/2006 15:50:00 8.1 0.6 9.9 6.5 8.2 0.6 9.9 6.5 8 0.8 9.5 5.7 138 4 124 165 10.2 0 10.6 9.8 07/17/2006 16:00:00 8.7 0.5 9.9 6.5 8.8 0.5 10.3 6.5 8.6 0.7 10.3 6.8 139 4 133 165 10.1 0 10.3 9.8 07/17/2006 16:10:00 8.4 0.7 10.3 6.5 8.5 0.7 10.3 6.5 8.1 0.9 9.9 5.3 137 6 139 165 10.1 0 10.3 9.8 07/17/2006 16:20:00 8.7 0.6 10.3 7.2 8.8 0.6 10.3 6.8 8.6 0.7 10.7 6.1 139 6 126 165 10 0 10.3 9.6 07/17/2006 16:30:00 9 0.8 11.1 6.8 9 0.8 10.7 6.5 8.8 0.8 10.7 6.8 143 6 142 165 9.8 0 10.3 9.6 07/17/2006 16:40:00 8.3 0.7 10.3 6.5 8.3 0.7 9.9 6.8 8.1 0.8 9.9 6.1 142 6 143 165 9.7 0 9.8 9.3 07/17/2006 16:50:00 7.4 0.8 9.9 5.3 7.4 0.8 9.5 4.9 7.2 0.7 9.1 5.7 140 6 151 165 9.8 0 9.8 9.6 07/17/2006 17:00:00 7.3 0.6 8.8 5.7 7.3 0.6 8.8 5.3 7.3 0.7 9.1 5.3 140 6 140 165 9.8 0 9.8 9.6 07/17/2006 17:10:00 7 1.2 10.7 4.2 7 1.2 11.1 4.6 6.8 1.1 10.7 3.8 144 8 128 165 9.8 0 10.1 9.3 07/17/2006 17:20:00 9.7 1 11.8 6.8 9.8 1 11.8 6.5 9.3 1 11.8 6.5 136 6 137 165 10 0.1 10.3 9.6 07/17/2006 17:30:00 9.7 1.1 11.8 5.7 9.8 1.1 11.8 6.5 9.4 1.1 11.8 6.8 138 6 142 165 10.1 0.1 10.3 9.6 07/17/2006 17:40:00 9.5 0.8 11.1 7.2 9.4 0.8 11.1 7.2 9.3 0.8 11.5 6.8 140 6 135 165 10.1 0.1 10.3 9.8 07/17/2006 17:50:00 8.9 1 11.1 6.5 9 1 11.1 6.5 8.6 1.3 11.1 4.6 137 7 141 165 10.1 0 10.3 9.8 07/17/2006 18:00:00 9.3 1 11.8 6.1 9.3 1 11.8 5.7 8.9 1 11.1 5.7 136 6 139 165 10.1 0 10.3 9.8 07/17/2006 18:10:00 9.3 0.9 11.1 6.8 9.3 0.9 11.5 6.5 9 0.9 11.1 5.7 134 6 135 165 10.1 0 10.3 9.8 07/17/2006 18:20:00 8.4 0.9 9.9 5.3 8.3 0.9 9.9 5.3 8 0.9 9.9 5.7 134 6 132 165 10.2 0 10.3 9.8 07/17/2006 18:30:00 9.3 1.1 12.2 6.8 9.3 1.1 12.2 6.8 9 1.2 12.6 6.1 135 7 135 165 10.3 0 10.6 9.8 07/17/2006 18:40:00 10.2 1.1 14.1 7.2 10.2 1.1 13.7 7.2 9.9 1.1 13.3 6.8 141 6 141 165 10.3 0 10.6 9.8 07/17/2006 18:50:00 10.7 1 13.7 8 10.7 1 13.3 7.6 10.3 1.1 13.3 7.6 139 5 140 165 10.4 0 10.6 10.1 07/17/2006 19:00:00 11.1 1 13.3 7.6 11.1 1 13.3 8 10.8 1.1 13.3 7.2 139 7 143 165 10.5 0 10.6 10.1 07/17/2006 19:10:00 11.2 1 13.7 8 11.2 1 13.7 8 10.9 1.1 13.7 7.6 141 7 129 165 10.5 0 10.6 10.3 07/17/2006 19:20:00 10.8 0.8 13 8.8 10.8 0.8 13 8.8 10.6 0.8 13 8.8 142 6 142 165 10.5 0 10.6 10.3 07/17/2006 19:30:00 11.1 0.9 13.7 9.1 11.1 0.9 13.7 8.8 10.8 1.1 13.7 8 142 6 146 165 10.5 0 10.6 10.1 07/17/2006 19:40:00 10.9 1 13.3 8 10.9 0.9 13.3 8.4 10.7 1 13.3 8 143 6 141 165 10.4 0 10.9 10.1 07/17/2006 19:50:00 10.4 0.9 13 8.4 10.4 0.9 12.6 8.4 10.2 0.9 12.6 7.6 143 6 141 165 10.4 0 10.6 10.1 07/17/2006 20:00:00 10.8 1 13 8 10.9 1 13 8.4 10.4 1 13 7.6 140 7 137 165 10.4 0 10.9 10.1 07/17/2006 20:10:00 11.1 0.7 12.6 8.8 11.1 0.8 13 8.4 10.9 0.8 13.3 8.4 143 7 144 165 10.3 0 10.9 10.1 07/17/2006 20:20:00 10.6 0.7 13.3 8.4 10.6 0.8 13.7 8.4 10.3 0.9 12.6 7.6 142 7 145 165 10.3 0 10.6 9.8 07/17/2006 20:30:00 9.9 1 13 7.6 9.9 0.9 13 7.6 9.7 1 12.2 7.2 144 5 138 165 10.3 0 10.6 9.8 07/17/2006 20:40:00 9.9 0.9 12.6 7.2 9.9 1 12.2 7.2 9.7 0.9 12.2 6.8 142 7 140 165 10.3 0 10.6 9.8 07/17/2006 20:50:00 10.3 0.9 13 8 10.3 0.9 13 6.8 10.1 0.9 12.6 6.8 141 6 143 165 10.3 0 10.9 9.8 07/17/2006 21:00:00 10.5 0.8 12.6 8.4 10.5 0.8 12.6 8 10.3 1 12.6 7.6 142 7 135 165 10.3 0 10.9 9.8 07/17/2006 21:10:00 11.3 1 13.7 7.2 11.3 1 13.3 7.6 11 1.1 13.3 7.6 140 6 135 165 10.3 0 10.6 9.8 07/17/2006 21:20:00 10.7 1 13.7 8.4 10.7 1 13.3 8.4 10.5 1 14.1 7.6 142 7 145 165 10.3 0.1 10.6 9.8 07/17/2006 21:30:00 10.6 1 13 7.6 10.5 1 13 7.6 10.3 1.1 12.6 7.2 142 7 135 165 10.1 0.1 10.6 9.8 07/17/2006 21:40:00 10.1 0.9 13 8 10.1 0.9 12.6 7.6 9.8 0.9 12.6 6.8 142 6 135 165 10.1 0.1 10.3 9.6 07/17/2006 21:50:00 9.9 0.9 12.2 7.6 9.9 0.9 12.2 7.6 9.7 0.8 11.8 7.6 142 5 140 165 10.1 0.2 10.9 9.6 07/17/2006 22:00:00 9.4 0.8 11.5 7.6 9.4 0.8 11.5 7.2 9 1 11.1 6.1 140 6 132 165 10.1 0.2 10.3 9.6 07/17/2006 22:10:00 9.8 0.8 12.2 7.6 9.8 0.9 12.2 7.6 9.7 0.9 12.2 7.2 144 6 136 165 10.1 0.1 10.6 9.6 07/17/2006 22:20:00 10 1 13 7.6 10 1 13 7.2 9.8 1 12.2 7.2 141 6 143 165 10.3 0 10.9 9.6 07/17/2006 22:30:00 9.6 0.8 11.8 6.1 9.6 0.8 11.8 6.5 9.3 1 12.2 6.5 142 6 144 165 10.3 0 10.6 9.8 07/17/2006 22:40:00 9.7 0.9 11.8 7.6 9.7 0.9 12.2 7.6 9.6 0.9 12.2 6.8 145 6 145 165 10.3 0 10.9 9.6 07/17/2006 22:50:00 9.5 0.8 11.8 7.6 9.5 0.8 11.5 7.6 9.3 0.9 11.5 5.7 141 6 141 165 10.3 0 10.6 9.8 07/17/2006 23:00:00 9.3 0.7 11.1 7.2 9.3 0.7 11.1 7.2 9.2 0.8 12.2 7.2 144 6 136 165 10.3 0 10.6 9.6 07/17/2006 23:10:00 9.6 0.7 11.5 7.6 9.6 0.7 11.5 7.6 9.5 0.7 11.5 6.8 143 5 140 165 10.3 0 10.6 9.8 07/17/2006 23:20:00 9.1 0.9 11.5 6.5 9.1 0.9 11.5 6.8 8.9 0.9 11.1 6.5 143 6 145 165 10.3 0 10.6 9.8 07/17/2006 23:30:00 9 1.3 11.8 5.3 9.1 1.3 11.8 5.3 8.7 1.3 11.8 5.7 138 7 138 165 10.2 0 10.6 9.8 07/17/2006 23:40:00 10.3 0.9 12.6 8 10.2 1 13 6.8 10.1 0.9 12.2 7.2 142 6 133 165 10.3 0 10.6 9.8 07/17/2006 23:50:00 10.1 0.8 12.2 6.8 10.1 0.8 12.2 7.2 9.8 0.8 12.2 7.2 140 6 144 165 10.3 0 10.6 9.8 07/18/2006 00:00:00 9.7 0.7 11.5 7.6 9.7 0.8 11.5 7.6 9.6 0.9 11.8 6.5 141 5 154 165 10.3 0 10.6 9.6 07/18/2006 00:10:00 9.7 0.8 11.5 7.2 9.7 0.8 11.5 7.2 9.6 0.8 11.1 7.6 141 5 140 165 10.3 0 10.6 9.6 07/18/2006 00:20:00 10 0.9 12.6 7.2 10.1 1 12.6 7.6 9.7 1 12.6 6.8 140 6 143 165 10.3 0 10.6 9.8 07/18/2006 00:30:00 10.4 0.9 13 8 10.4 0.9 12.6 8 10.2 1 12.6 6.8 142 6 141 165 10.1 0.2 10.3 9.6 07/18/2006 00:40:00 11.1 1 13.3 8.4 11.1 1 13.3 8 10.9 1 13.3 7.6 141 6 148 165 10.1 0.2 10.6 9.6 07/18/2006 00:50:00 10.7 1 13.3 8.4 10.8 1 13.3 8.4 10.5 1.1 12.6 7.2 141 6 138 165 10.1 0.2 10.3 9.6 07/18/2006 01:00:00 10.9 1.1 13 7.6 11 1.1 13.3 7.6 10.7 1 13 7.6 140 6 137 165 10.1 0.2 10.3 9.6 07/18/2006 01:10:00 11.5 1.2 14.5 8 11.5 1.2 14.5 8 11.1 1.3 13.3 7.6 139 6 140 165 10.1 0.2 10.6 9.6 07/18/2006 01:20:00 11.8 1 14.1 8.8 11.9 1 14.1 9.1 11.4 1.2 14.1 8 140 5 140 165 10.1 0.2 10.3 9.6 07/18/2006 01:30:00 11.2 1 13.3 9.1 11.2 1 13.7 8.8 10.8 1.1 13.7 8 139 6 138 165 10.1 0.2 10.3 9.6 07/18/2006 01:40:00 10.4 1.2 13 6.8 10.4 1.2 13 7.2 10 1.3 12.6 6.5 139 6 137 165 10 0.2 10.3 9.3 07/18/2006 01:50:00 10.4 0.9 13.3 8.4 10.4 1 13 8 10.3 1 12.2 7.6 143 6 147 165 10 0.2 10.6 9.6 07/18/2006 02:00:00 11.1 0.8 13.3 9.1 11 0.8 13 9.1 11 0.8 13 8.8 143 5 132 165 10 0.2 10.3 9.3 07/18/2006 02:10:00 10.8 0.9 13 7.6 10.7 0.9 13 7.2 10.6 1 13.3 7.6 145 6 147 165 10 0.2 10.6 9.3 07/18/2006 02:20:00 11.2 1.2 14.5 8.8 11.2 1.2 14.5 8.4 10.8 1.4 14.1 7.6 141 6 151 165 10 0.1 10.3 9.3 07/18/2006 02:30:00 11.4 0.8 14.1 9.5 11.4 0.8 13.7 9.1 11.3 0.8 13.7 8.8 143 5 142 165 9.8 0.1 10.1 9.3 07/18/2006 02:40:00 10.6 0.7 12.6 8 10.6 0.8 12.2 8.4 10.4 1 13 7.2 143 6 143 165 9.8 0 10.1 9.3 07/18/2006 02:50:00 10.4 0.9 12.6 7.6 10.5 0.9 12.6 7.2 10.2 1.1 12.6 7.2 141 7 142 165 9.9 0 10.1 9.3 07/18/2006 03:00:00 10.3 0.9 13 7.2 10.3 1 13.7 7.2 10.1 1 13.3 7.2 139 7 130 165 9.8 0 9.8 9.3 07/18/2006 03:10:00 10.3 1.1 12.6 6.8 10.3 1.1 12.6 6.5 9.9 1.2 12.6 5.7 140 7 141 165 9.8 0 9.8 9.3 07/18/2006 03:20:00 10.9 1 13.7 8 10.9 1 14.1 8 10.6 1.1 13.7 7.6 141 7 145 165 9.8 0 9.8 9.3 07/18/2006 03:30:00 12.4 0.9 14.5 9.1 12.5 0.9 14.1 9.1 12.1 1 14.1 8.8 140 6 139 165 9.8 0 10.3 9.3 07/18/2006 03:40:00 11 0.8 13 9.1 11 0.8 13 9.5 10.9 0.9 13.7 8.4 148 5 145 165 9.8 0 9.8 9.6 07/18/2006 03:50:00 9.5 0.9 11.5 7.2 9.5 0.9 11.8 7.2 9.4 0.9 11.5 7.2 143 5 141 165 9.7 0 9.8 9.3 07/18/2006 04:00:00 8.9 0.6 10.7 7.2 8.9 0.6 11.1 6.8 8.6 0.9 10.3 6.1 138 6 127 165 9.7 0 9.8 9.3 07/18/2006 04:10:00 10.2 0.9 12.2 7.6 10.2 0.9 12.2 7.6 9.9 1 12.2 7.2 139 6 136 165 9.7 0 9.8 9.3 07/18/2006 04:20:00 9.8 0.9 11.8 7.6 9.8 0.9 12.2 7.2 9.6 0.9 12.2 6.8 141 6 138 165 9.8 0 10.1 9.6 07/18/2006 04:30:00 10.3 0.8 12.2 7.6 10.3 0.8 12.2 7.6 10 0.8 11.5 8 142 6 142 165 9.6 0.1 9.8 9 07/18/2006 04:40:00 9.2 0.8 11.1 6.8 9.1 0.9 11.5 6.8 9 0.8 11.5 7.2 140 6 139 165 9.6 0 9.8 9 07/18/2006 04:50:00 8.8 1 11.8 6.1 8.9 1 11.8 5.7 8.6 1 11.5 5.7 133 6 140 165 9.6 0 9.6 9.6 07/18/2006 05:00:00 10.4 1.2 14.1 7.2 10.4 1.2 14.1 7.2 10.2 1.2 13.7 7.2 132 7 139 165 9.6 0 10.3 9 07/18/2006 05:10:00 11.8 1 14.5 8.8 11.9 1 14.9 8.4 11.7 1.2 14.1 8 136 7 137 165 9.5 0 9.8 9 07/18/2006 05:20:00 10.6 1 13.3 7.6 10.7 1.1 13.7 7.6 10.2 1 13.7 7.2 133 7 140 165 9.6 0 9.6 9.3 07/18/2006 05:30:00 11.4 1.1 14.1 8.8 11.4 1.1 13.7 9.1 11.1 1.2 13.3 8 135 6 143 165 9.6 0 9.6 9.6 07/18/2006 05:40:00 11.2 1.1 13.7 9.1 11.2 1 13.7 8.8 10.7 1.2 13.7 7.2 136 6 133 165 9.6 0 9.6 9 07/18/2006 05:50:00 10.3 1 12.6 8 10.3 1 12.6 8 10.2 1.1 13 7.2 136 7 133 165 9.5 0 9.6 9.3 07/18/2006 06:00:00 10.7 0.9 13.3 7.6 10.8 0.9 13.7 8 10.6 1 13.3 7.6 134 7 124 165 9.2 0.1 9.6 9 07/18/2006 06:10:00 10.3 1 12.6 8 10.4 1 12.6 7.6 10 1.1 13 7.2 133 7 133 165 9 0 9 8.8 07/18/2006 06:20:00 10.4 1.1 14.5 6.8 10.6 1.1 14.9 7.6 10.3 1.1 14.5 7.6 130 7 125 165 9 0 9.3 8.8 07/18/2006 06:30:00 10.4 1.1 13.7 7.6 10.6 1.1 13.7 7.6 10.4 1 13 7.2 127 6 129 165 9 0 9 8.8 07/18/2006 06:40:00 10.8 1.2 14.5 8 11.1 1.2 14.5 8.4 10.7 1.2 14.1 8 125 7 121 165 9 0 9.6 8.5 07/18/2006 06:50:00 10.8 1 14.1 8.4 11 1 14.5 8.4 10.5 1 14.1 7.6 126 5 117 165 8.9 0 9 8.8 07/18/2006 07:00:00 11 1.2 15.3 8.4 11.3 1.2 15.3 8.8 10.7 1.2 16.1 7.6 124 6 125 165 8.9 0 9 8.5 07/18/2006 07:10:00 11.3 1.1 14.1 8.4 11.6 1.1 14.9 8.8 11.2 1.2 14.9 7.6 124 6 116 165 8.9 0 9 8.5 07/18/2006 07:20:00 11.5 1.2 14.5 8.4 11.7 1.2 14.5 8.4 11.2 1.2 14.5 8 123 5 118 165 8.9 0 9 8.5 07/18/2006 07:30:00 11.4 1.2 15.3 8 11.5 1.2 14.9 8 11 1.3 13.7 7.6 121 6 113 165 9 0 9 8.8 07/18/2006 07:40:00 11.1 1 14.1 9.1 11.3 1 14.1 8.8 10.6 1.1 13.3 7.6 119 6 124 165 9 0 9.6 9 07/18/2006 07:50:00 11.9 1.3 14.9 7.6 12 1.3 15.3 7.2 11.5 1.5 14.9 6.8 117 6 109 165 9 0 9 9 07/18/2006 08:00:00 11.5 1.3 15.3 8.8 11.7 1.3 15.6 8.8 11 1.3 14.9 8 119 7 111 165 8.9 0 9 9 07/18/2006 08:10:00 12.2 1.2 14.9 8.8 12.4 1.2 15.3 8.8 11.6 1.3 14.5 8.4 116 6 118 165 9 0 9 9 07/18/2006 08:20:00 12 1.5 15.6 8 12.3 1.5 16.4 8.4 11.5 1.5 15.6 7.6 119 6 118 165 9.1 0 9.3 9 07/18/2006 08:30:00 10.7 1.2 14.1 7.2 11 1.2 14.5 7.2 10.2 1.1 13 6.8 119 6 111 165 9.1 0 9.3 9 07/18/2006 08:40:00 11.8 1.1 14.5 8.8 12.1 1.2 15.3 9.1 11.2 1.2 14.5 8.8 117 5 114 165 9.1 0 9.6 9 07/18/2006 08:50:00 11.7 1.3 14.9 7.6 11.9 1.3 15.3 7.2 11.1 1.3 15.6 7.2 117 7 114 165 9.1 0 9.3 9 07/18/2006 09:00:00 11.6 1.3 14.9 8 11.8 1.3 14.9 8 11.2 1.4 14.5 7.2 118 6 110 165 9.1 0 9 9 07/18/2006 09:10:00 12.1 1.3 15.6 9.1 12.3 1.3 15.6 9.1 11.6 1.3 14.9 8 118 6 118 165 9.1 0 9.3 9 07/18/2006 09:20:00 11.7 1.2 14.5 8.4 12 1.2 14.9 8.4 11.1 1.2 14.5 8.4 117 7 124 165 9.1 0 9.3 9 07/18/2006 09:30:00 13.1 1.5 16.8 8.8 13.3 1.5 17.6 8.4 12.4 1.5 16.8 8.4 117 7 119 165 9.1 0 9 8.8 07/18/2006 09:40:00 12.8 1.5 17.2 9.5 13 1.5 17.6 9.5 12.1 1.6 16.1 8.8 116 7 116 165 9 0 9.3 8.8 07/18/2006 09:50:00 12.6 1.3 16.1 9.1 12.8 1.4 16.1 8.8 12 1.5 15.6 8.4 117 6 121 165 9 0 9 8.8 07/18/2006 10:00:00 12.9 1.5 17.9 9.5 13.2 1.5 18.3 9.5 12.2 1.7 17.2 8.4 115 6 113 165 9 0 9.3 8.8 07/18/2006 10:10:00 12.8 1.2 16.1 8.8 13.1 1.2 16.4 9.5 12.2 1.4 15.6 8 114 6 115 165 9.1 0 9.3 9 07/18/2006 10:20:00 12.6 1.5 16.1 8.8 12.8 1.5 16.4 8.4 11.9 1.5 15.6 7.6 115 7 111 165 9.1 0 9.3 9 07/18/2006 10:30:00 13 1.3 16.1 9.5 13.2 1.3 16.4 9.9 12.4 1.2 15.3 8 117 5 112 165 9.2 0 9.3 9 07/18/2006 10:40:00 12.9 1.3 16.1 9.5 13.1 1.3 16.4 9.9 12.3 1.3 15.6 8.4 114 6 118 165 9.3 0 9.3 9 07/18/2006 10:50:00 13.3 1.5 17.2 8.8 13.5 1.5 17.6 9.1 12.7 1.5 16.8 9.1 115 6 118 165 9.4 0 9.6 9 07/18/2006 11:00:00 12.4 1.7 16.4 8 12.6 1.7 16.8 8 11.6 1.8 16.8 6.8 116 7 119 165 9.6 0 9.6 9.3 07/18/2006 11:10:00 12.7 1.3 16.4 8 12.9 1.3 17.2 8.4 11.9 1.5 15.6 8 116 6 109 165 9.6 0 9.6 9.3 07/18/2006 11:20:00 12.1 1.5 16.1 8 12.3 1.5 16.4 8.4 11.4 1.6 15.3 7.2 119 7 125 165 9.6 0 9.8 9.3 07/18/2006 11:30:00 13.5 1.8 21.8 9.1 13.7 1.8 21.8 8.4 12.8 1.8 21.4 8.4 120 8 110 165 9.6 0 9.8 9.6 07/18/2006 11:40:00 14.6 1.7 19.1 9.1 14.8 1.7 19.1 9.5 14.1 1.7 18.7 9.9 121 5 118 165 9.8 0 9.8 9.6 07/18/2006 11:50:00 12.9 1.4 16.8 8.8 13.1 1.5 16.8 8.4 12.1 1.5 16.4 8.4 118 7 121 165 10 0 10.1 9.3 07/18/2006 12:00:00 11.9 1.2 14.9 8.8 12.1 1.2 14.9 8.8 11.3 1.2 14.5 8.4 118 7 119 165 9.9 0 10.1 9.3 07/18/2006 12:10:00 12.8 1.2 16.1 10.3 13 1.2 16.1 10.3 12.3 1.3 15.6 8.8 118 6 121 165 9.9 0 10.1 9.3 07/18/2006 12:20:00 12.6 1.2 16.1 9.5 12.7 1.2 16.4 9.5 11.8 1.3 15.3 8.4 120 6 117 165 10 0 10.3 9.6 07/18/2006 12:30:00 12.4 1.3 16.8 8.4 12.6 1.3 17.2 8.4 11.7 1.3 15.6 8.4 117 6 110 165 10.1 0.1 10.3 9.6 07/18/2006 12:40:00 13.8 1.5 19.1 9.9 14.1 1.5 19.5 9.9 13 1.7 17.2 8.8 117 6 112 165 10.1 0.1 10.6 9.6 07/18/2006 12:50:00 14.6 1.5 18.7 10.3 14.9 1.6 19.1 10.7 14.1 1.6 19.1 9.9 121 6 107 165 10.1 0.1 10.6 9.6 07/18/2006 13:00:00 14.2 1.5 17.9 9.9 14.4 1.5 18.3 9.5 13.6 1.6 17.6 9.1 122 6 112 165 10.1 0.1 10.3 9.6 07/18/2006 13:10:00 14 1.7 17.9 9.5 14.2 1.7 17.9 9.5 13.7 1.7 17.6 9.5 124 8 123 165 10.1 0.1 10.3 9.6 07/18/2006 13:20:00 13.8 1.6 17.9 10.3 14.1 1.6 17.9 10.3 13.4 1.7 18.7 8.8 125 6 126 165 10.2 0.1 10.3 9.6 07/18/2006 13:30:00 14.1 1.8 18.7 8.4 14.3 1.8 18.7 8 13.8 2 18.7 8.4 123 6 116 165 10.2 0.1 10.9 9.6 07/18/2006 13:40:00 14.1 1.6 18.7 9.9 14.4 1.7 19.1 9.1 13.5 1.7 17.9 9.5 121 7 123 165 10.3 0.1 10.6 9.6 07/18/2006 13:50:00 15.1 1.7 20.2 10.7 15.4 1.7 20.6 10.7 14.6 1.7 19.1 10.3 122 6 123 165 10.2 0.1 10.9 9.6 07/18/2006 14:00:00 14.5 1.7 18.3 10.3 14.7 1.8 19.1 9.9 14 1.8 19.1 8.8 123 7 122 165 10.3 0 10.6 9.6 07/18/2006 14:10:00 15.3 1.8 19.5 11.1 15.6 1.8 19.9 11.5 14.9 1.8 19.1 10.3 121 6 118 165 10.1 0.2 10.6 9.6 07/18/2006 14:20:00 14.8 1.7 19.1 10.3 15.1 1.8 19.5 10.7 14.1 1.9 19.1 9.9 120 7 116 165 10.2 0.1 10.6 9.6 07/18/2006 14:30:00 14 1.7 17.9 9.9 14.2 1.7 18.7 9.9 13.4 1.9 17.9 8.8 118 7 121 165 10.2 0.2 10.6 9.6 07/18/2006 14:40:00 13.5 1.6 16.8 9.1 13.8 1.6 17.2 9.9 12.8 1.5 16.4 9.1 119 7 113 165 10.1 0.2 10.6 9.6 07/18/2006 14:50:00 13.9 1.3 18.3 9.5 14.1 1.3 18.7 9.9 13.3 1.5 17.2 9.5 117 7 115 165 10.1 0.2 10.9 9.6 07/18/2006 15:00:00 13.8 1.5 18.7 9.5 14.1 1.5 18.7 9.5 13.1 1.7 17.9 8 117 6 112 165 10.1 0.2 10.9 9.6 07/18/2006 15:10:00 13.9 1.4 17.6 9.9 14.1 1.5 18.3 9.5 13.2 1.7 17.6 8.8 116 6 111 165 10.1 0.2 10.6 9.6 07/18/2006 15:20:00 14.5 1.5 19.5 11.5 14.8 1.5 19.9 11.5 13.7 1.6 19.1 9.5 115 6 116 165 10.1 0.2 10.3 9.6 07/18/2006 15:30:00 14.3 1.5 17.6 8.8 14.5 1.5 17.9 8.4 13.6 1.6 16.8 9.1 114 6 114 165 10.1 0.2 10.6 9.6 07/18/2006 15:40:00 15.1 1.5 18.7 10.3 15.3 1.5 19.1 10.3 14.1 1.5 17.9 10.3 112 6 97 165 10.1 0.2 10.3 9.6 07/18/2006 15:50:00 14.7 1.6 19.5 9.5 15 1.7 20.2 9.5 13.8 1.7 17.9 9.9 111 6 108 165 10.1 0.2 10.6 9.6 07/18/2006 16:00:00 15 1.5 18.7 9.5 15.2 1.6 19.1 9.5 14.1 1.7 18.3 8.8 111 6 114 165 10.1 0.2 10.3 9.6 07/18/2006 16:10:00 14.4 1.5 18.3 9.5 14.7 1.6 18.3 9.5 13.6 1.6 17.9 9.5 112 6 106 165 10.1 0.2 10.6 9.6 07/18/2006 16:20:00 15 1.5 17.9 10.7 15.2 1.5 18.3 10.7 14 1.7 17.6 9.5 111 6 107 165 10.1 0.2 10.6 9.6 07/18/2006 16:30:00 15.2 1.7 21.4 10.3 15.5 1.7 21.4 10.3 14.4 1.8 20.6 9.5 110 6 110 165 10.1 0.1 10.6 9.6 07/18/2006 16:40:00 15.5 1.6 19.9 10.3 15.8 1.6 20.2 10.7 14.6 1.9 19.9 9.1 111 6 121 165 10.1 0.1 10.3 9.6 07/18/2006 16:50:00 15.4 1.7 19.5 11.1 15.7 1.7 19.9 11.1 14.5 1.9 19.1 8 110 6 116 165 10.1 0.1 10.3 9.6 07/18/2006 17:00:00 15.3 1.5 19.5 10.3 15.6 1.6 19.9 9.9 14.2 1.8 19.5 9.9 111 6 108 165 10.1 0.1 10.9 9.6 07/18/2006 17:10:00 15.4 1.7 19.5 9.1 15.6 1.7 19.5 9.1 14.3 1.8 18.3 9.5 111 6 111 165 10 0 10.3 9.6 07/18/2006 17:20:00 15 1.8 19.5 9.9 15.2 1.8 19.5 9.9 14.1 2 18.3 9.1 111 7 106 165 10 0 10.3 9.6 07/18/2006 17:30:00 15.4 1.7 19.5 10.3 15.6 1.7 20.2 10.7 14.5 1.8 20.2 9.9 108 6 110 165 10 0 10.6 9.6 07/18/2006 17:40:00 15.6 1.7 20.2 9.9 15.9 1.8 20.2 9.1 14.7 1.8 21 9.5 108 6 106 165 10 0 10.3 9.6 07/18/2006 17:50:00 16 1.5 19.5 10.7 16.3 1.5 19.9 10.7 15.1 1.7 19.5 9.5 108 6 116 165 10 0 10.6 9.6 07/18/2006 18:00:00 16.5 1.2 20.2 12.6 16.8 1.2 20.6 13 15.6 1.6 19.5 9.9 107 6 119 165 10 0 10.3 9.6 07/18/2006 18:10:00 15.8 1.5 19.5 11.1 16.2 1.5 20.2 11.1 14.9 1.7 18.3 9.9 109 5 111 165 10 0 10.3 9.6 07/18/2006 18:20:00 15.4 1.6 19.1 11.1 15.7 1.7 19.9 11.1 14.3 1.8 18.7 9.9 109 6 113 165 10 0 10.3 9.6 07/18/2006 18:30:00 16.1 1.5 19.5 12.2 16.4 1.5 19.9 12.2 15.1 1.7 18.7 11.1 108 6 108 165 10 0 10.3 9.6 07/18/2006 18:40:00 16.3 1.5 19.5 11.8 16.6 1.5 20.2 12.2 15.5 1.6 19.5 11.1 106 6 107 165 10 0 10.6 9.6 07/18/2006 18:50:00 16 1.5 19.5 11.5 16.3 1.5 19.9 11.8 14.9 1.6 19.1 9.9 105 5 102 165 10 0.1 10.6 9.6 07/18/2006 19:00:00 15.8 1.7 20.2 10.3 16.1 1.8 20.2 10.3 14.7 1.8 18.7 9.5 103 7 111 165 10 0.1 10.6 9.6 07/18/2006 19:10:00 16.2 1.7 20.2 11.5 16.5 1.7 20.2 11.8 15 1.7 19.5 10.3 104 6 104 165 10 0.1 10.3 9.6 07/18/2006 19:20:00 16.6 1.7 20.2 11.8 16.9 1.7 20.6 12.2 15.7 1.9 20.6 10.7 105 6 106 165 10 0.1 10.3 9.6 07/18/2006 19:30:00 16.5 1.7 21 10.7 16.7 1.7 20.6 10.7 15.4 1.9 19.1 9.5 107 6 111 165 10 0.1 10.6 9.6 07/18/2006 19:40:00 16.6 1.6 20.2 11.8 16.9 1.6 20.6 11.8 15.8 1.7 20.2 11.1 106 6 103 165 10 0.1 10.1 9.6 07/18/2006 19:50:00 16.8 1.7 21 10.7 17.1 1.7 21.4 10.7 15.8 1.9 20.6 11.1 106 6 111 165 10 0.1 10.3 9.6 07/18/2006 20:00:00 16.2 1.7 20.6 10.7 16.5 1.7 20.6 11.1 15.3 1.9 21.4 11.1 108 6 113 165 10 0 10.3 9.6 07/18/2006 20:10:00 16.5 1.6 20.2 10.3 16.8 1.6 20.2 10.7 15.5 1.8 19.5 9.9 108 6 104 165 10 0.1 10.1 9.6 07/18/2006 20:20:00 16.1 2 21 10.7 16.4 2 21.4 10.3 15.1 2.1 20.6 9.5 108 7 104 165 10 0.1 10.3 9.6 07/18/2006 20:30:00 17 1.8 21.4 11.5 17.3 1.9 21.8 12.2 16.1 2.1 21.4 10.3 107 6 106 165 10 0.1 10.3 9.6 07/18/2006 20:40:00 16.6 1.6 20.6 12.2 16.9 1.6 21 11.5 15.7 1.7 19.9 10.7 107 6 104 165 10 0.1 10.3 9.6 07/18/2006 20:50:00 16.4 1.5 20.6 12.6 16.8 1.6 21.8 11.8 15.4 1.7 19.9 11.5 106 6 100 165 10 0.1 10.6 9.6 07/18/2006 21:00:00 16.8 1.5 20.2 12.2 17.1 1.6 20.6 11.8 15.6 1.8 19.5 10.3 107 6 114 165 10 0 10.3 9.6 07/18/2006 21:10:00 16.6 1.5 19.9 11.8 16.9 1.5 20.6 11.8 15.6 1.8 19.5 10.7 107 6 114 165 10 0 10.6 9.6 07/18/2006 21:20:00 17 1.3 19.9 12.6 17.4 1.4 19.9 13 16.1 1.7 20.2 11.1 105 5 102 165 10 0 10.3 9.6 07/18/2006 21:30:00 16.7 1.7 20.2 11.5 17 1.7 20.6 11.5 15.8 1.7 20.2 10.7 106 6 107 165 10 0 10.3 9.6 07/18/2006 21:40:00 16.6 1.6 21 11.1 16.9 1.6 21 11.1 15.4 1.7 19.5 10.7 105 5 106 165 10 0 10.3 9.6 07/18/2006 21:50:00 16.5 1.3 19.5 11.5 16.8 1.3 19.9 11.8 15.5 1.5 18.7 10.7 104 5 118 165 10 0 10.3 9.6 07/18/2006 22:00:00 16.3 1.4 19.5 12.2 16.6 1.4 19.9 12.6 15.1 1.6 19.1 10.3 103 6 106 165 10 0 10.3 9.6 07/18/2006 22:10:00 15.9 1.5 19.5 11.5 16.2 1.6 19.9 11.5 14.7 1.8 19.1 10.3 102 7 105 165 10 0 10.3 9.6 07/18/2006 22:20:00 15.3 1.7 19.5 9.9 15.5 1.8 20.2 9.9 14.1 1.8 17.9 8.8 99 6 96 165 10 0 10.3 9.6 07/18/2006 22:30:00 15.8 1.9 19.9 10.7 16.1 2 20.2 11.1 14.5 1.9 19.5 9.5 99 7 99 165 10.1 0 10.6 9.6 07/18/2006 22:40:00 15.9 1.8 19.9 11.5 16.2 1.8 20.2 11.5 14.8 2.1 20.2 9.5 99 7 112 165 10.1 0.1 10.3 9.6 07/18/2006 22:50:00 15.4 1.7 19.9 10.7 15.7 1.7 20.2 10.7 14.3 1.7 18.3 9.1 97 7 94 165 10.1 0.1 10.3 9.6 07/18/2006 23:00:00 15.4 1.5 18.7 11.1 15.7 1.5 19.5 11.1 14.1 1.7 19.1 10.3 96 7 105 165 10.1 0.1 10.3 9.6 07/18/2006 23:10:00 15.1 1.7 19.1 9.5 15.4 1.8 19.9 9.9 14 1.7 17.9 9.1 95 8 87 165 10.1 0.1 10.9 9.6 07/18/2006 23:20:00 15.6 1.6 19.1 10.7 15.9 1.7 19.5 10.3 14.5 1.7 19.1 9.9 93 6 95 165 10.1 0.1 10.3 9.6 07/18/2006 23:30:00 16.3 1.7 19.9 11.5 16.6 1.7 20.6 12.2 15.2 1.9 19.9 9.5 92 6 90 165 10.1 0.1 10.3 9.6 07/18/2006 23:40:00 15.6 1.6 19.1 11.1 15.9 1.6 19.1 11.8 14.5 1.7 19.9 9.9 93 7 96 165 10.1 0.1 10.3 9.6 07/18/2006 23:50:00 15.8 1.8 19.1 10.7 16.1 1.9 19.5 11.1 14.5 2 18.3 9.9 90 7 87 165 10.1 0.2 10.6 9.6 07/19/2006 00:00:00 16.1 1.5 19.9 9.9 16.4 1.7 20.2 10.3 14.9 1.7 18.7 8.8 91 6 91 165 10.1 0.1 10.3 9.6 07/19/2006 00:10:00 15.2 1.6 18.7 10.7 15.4 1.6 18.7 11.1 14 1.6 17.6 9.5 93 7 90 165 10.1 0.1 10.6 9.6 07/19/2006 00:20:00 15.8 1.7 19.9 9.9 16.1 1.7 20.6 10.3 14.6 1.8 19.1 9.5 92 6 90 165 10.1 0.1 10.3 9.6 07/19/2006 00:30:00 15.8 1.5 19.1 9.5 16.1 1.5 19.5 10.7 14.8 1.6 18.7 9.5 90 6 90 165 10.1 0.1 10.6 9.6 07/19/2006 00:40:00 16.2 1.3 18.7 11.8 16.6 1.4 19.5 11.8 15.3 1.5 19.1 9.9 89 5 90 165 10.1 0.1 10.3 9.6 07/19/2006 00:50:00 15.8 1.4 18.7 11.1 16.1 1.5 19.1 11.8 14.9 1.5 18.3 10.7 88 5 85 165 10.1 0.1 10.3 9.6 07/19/2006 01:00:00 15.7 1.4 18.7 10.7 16.1 1.5 19.1 11.5 14.7 1.5 18.3 10.3 89 5 85 165 10.1 0.1 10.6 9.6 07/19/2006 01:10:00 15.5 1.5 18.3 11.1 15.8 1.6 18.7 11.1 14.5 1.5 17.9 10.3 87 6 88 165 10.1 0.1 10.3 9.6 07/19/2006 01:20:00 15.4 1.6 18.7 10.7 15.8 1.7 19.1 10.7 14.5 1.6 17.9 10.3 85 6 87 165 10.1 0.1 10.9 9.6 07/19/2006 01:30:00 15.2 1.6 18.7 11.1 15.5 1.7 19.1 11.5 14.1 1.7 17.9 9.9 85 7 85 165 10.1 0.1 10.3 9.6 07/19/2006 01:40:00 15.1 1.5 18.3 9.5 15.4 1.6 18.7 9.9 14.1 1.7 17.9 10.3 85 7 94 165 10.1 0.1 10.3 9.6 07/19/2006 01:50:00 14.9 1.7 18.7 10.7 15.2 1.7 19.5 10.7 14.1 1.6 17.9 9.1 84 8 90 165 10.1 0.1 10.3 9.6 07/19/2006 02:00:00 15.4 1.6 19.1 11.1 15.7 1.7 19.1 11.5 14.5 1.7 18.3 9.5 83 6 84 165 10.1 0.1 10.3 9.6 07/19/2006 02:10:00 14.9 1.6 18.7 9.9 15.2 1.7 19.1 9.9 14.1 1.5 19.1 10.7 83 6 87 165 10.1 0.1 10.3 9.6 07/19/2006 02:20:00 15.4 1.7 18.7 10.3 15.7 1.8 19.1 9.9 14.5 1.7 18.7 9.9 83 5 84 165 10.1 0.1 10.3 9.6 07/19/2006 02:30:00 15 1.7 18.7 10.7 15.3 1.8 19.1 11.1 14.1 1.7 17.9 10.3 82 7 78 165 10.1 0.2 10.9 9.6 07/19/2006 02:40:00 15.4 1.7 18.7 11.1 15.7 1.7 19.1 11.1 14.7 1.6 18.3 9.9 81 6 82 165 10.1 0.1 10.3 9.6 07/19/2006 02:50:00 15.2 1.5 18.7 11.1 15.5 1.6 19.1 11.5 14.3 1.6 18.7 9.9 82 6 88 165 10.1 0.1 10.3 9.6 07/19/2006 03:00:00 15.1 1.6 18.7 10.3 15.4 1.7 19.1 10.7 14.4 1.6 18.3 9.9 81 6 84 165 10.1 0.1 10.3 9.6 07/19/2006 03:10:00 14.9 1.7 18.7 10.7 15.3 1.7 18.7 11.1 14.2 1.7 18.3 10.3 80 6 78 165 10.1 0.1 10.3 9.6 07/19/2006 03:20:00 14.3 1.5 17.2 10.3 14.6 1.5 17.6 9.9 13.6 1.5 16.8 9.1 79 7 84 165 10.1 0.1 10.3 9.6 07/19/2006 03:30:00 14.3 1.5 18.3 10.7 14.7 1.6 19.1 10.7 13.9 1.5 18.3 9.5 78 7 82 165 10.1 0.1 10.3 9.6 07/19/2006 03:40:00 13.7 1.6 18.3 9.5 14 1.7 19.1 9.1 13 1.7 17.6 8.8 78 8 85 165 10.1 0.1 10.3 9.6 07/19/2006 03:50:00 13.2 1.7 17.2 7.6 13.6 1.8 17.6 7.2 13 1.6 17.2 8.8 78 8 91 165 10.1 0.1 10.3 9.6 07/19/2006 04:00:00 13 1.8 17.2 8.8 13.3 1.8 17.6 8.4 12.5 1.7 16.4 7.6 78 8 84 165 10.1 0.1 10.3 9.6 07/19/2006 04:10:00 13 1.9 17.9 8 13.2 2 18.3 8 12.6 1.8 16.8 7.6 75 9 80 165 10.1 0.1 10.6 9.6 07/19/2006 04:20:00 13.5 1.8 17.6 8 13.8 1.9 17.9 7.6 13.1 1.8 17.6 8 77 8 83 165 10.1 0.1 10.3 9.6 07/19/2006 04:30:00 12.8 1.6 17.2 8.4 13 1.7 17.2 9.1 12.3 1.5 16.4 8.8 76 9 78 165 10.1 0.1 10.6 9.6 07/19/2006 04:40:00 13.2 2 17.6 8.4 13.4 2.1 18.3 7.6 12.6 1.9 17.6 7.6 75 9 84 165 10.1 0.1 10.3 9.6 07/19/2006 04:50:00 12.4 2.1 17.6 7.2 12.6 2.2 18.3 7.2 11.9 2.2 17.9 7.2 77 10 84 165 10.1 0.1 10.3 9.6 07/19/2006 05:00:00 12.9 2 19.1 8.4 13.2 2.1 19.1 8.8 12.5 1.9 17.9 8.4 75 8 78 165 10.1 0.1 10.9 9.6 07/19/2006 05:10:00 12.7 2 18.3 7.6 13 2.1 19.1 8 12.4 1.7 16.8 7.6 75 9 83 165 10.1 0.1 10.3 9.6 07/19/2006 05:20:00 12.3 1.9 16.8 7.2 12.6 2 17.2 7.6 11.9 1.9 16.4 8 75 9 65 165 10.1 0.1 10.3 9.6 07/19/2006 05:30:00 12.1 1.7 16.4 6.8 12.4 1.8 17.6 7.2 11.8 1.7 15.3 7.6 76 9 68 165 10.1 0.1 10.3 9.6 07/19/2006 05:40:00 12.8 1.8 16.4 8.4 13 1.9 16.8 7.6 12.2 1.7 16.8 8.8 76 9 80 165 10.1 0.1 10.6 9.6 07/19/2006 05:50:00 13.5 1.6 17.9 9.1 13.9 1.7 18.3 9.9 13.2 1.6 17.2 8.4 77 8 80 165 10.1 0.2 10.3 9.6 07/19/2006 06:00:00 12.6 1.5 16.4 8 12.8 1.6 16.8 8.4 12.1 1.5 15.3 7.2 75 9 74 165 10.1 0.1 10.3 9.6 07/19/2006 06:10:00 12.7 1.7 16.4 9.5 12.9 1.7 16.8 9.1 12.2 1.6 15.6 8.4 77 9 81 165 10.1 0.1 10.6 9.6 07/19/2006 06:20:00 12.3 1.8 16.4 7.2 12.6 1.8 16.8 7.2 12 1.6 17.2 7.6 76 8 95 165 10.1 0.1 10.3 9.6 07/19/2006 06:30:00 13.8 2 18.3 8.4 14.1 2.1 19.1 8.4 13.2 1.8 17.9 8.4 77 8 78 165 10.1 0.1 10.3 9.6 07/19/2006 06:40:00 13.4 2 17.9 8.4 13.7 2.1 18.7 8 12.8 1.9 17.9 8.4 77 9 68 165 10.1 0.1 10.6 9.6 07/19/2006 06:50:00 12.5 1.7 16.4 8.4 12.8 1.7 16.8 8.4 11.7 1.7 16.4 7.2 75 9 73 165 10.1 0.1 10.3 9.6 07/19/2006 07:00:00 13.9 1.8 19.5 9.5 14.2 1.9 20.2 9.9 13.4 1.8 19.1 9.1 76 9 84 165 10.1 0.1 10.3 9.6 07/19/2006 07:10:00 13.1 1.8 17.9 8.8 13.4 1.9 18.3 9.1 12.8 1.7 17.6 8.8 76 8 78 165 10.1 0.2 10.9 9.6 07/19/2006 07:20:00 13.1 2.3 19.5 8.8 13.4 2.4 20.2 8.4 12.6 2.2 19.1 8.8 77 9 81 165 10.1 0.1 10.3 9.6 07/19/2006 07:30:00 13.2 1.8 17.6 8.8 13.5 1.9 17.9 8.8 12.7 1.7 17.2 8 76 9 77 165 10.1 0.1 10.3 9.6 07/19/2006 07:40:00 13.9 1.9 19.1 9.5 14.2 2 19.1 8.8 13.5 1.8 17.9 9.1 77 9 85 165 10.1 0.1 10.3 9.6 07/19/2006 07:50:00 14.2 1.7 19.1 9.5 14.4 1.8 19.9 9.9 13.6 1.7 18.7 9.9 78 8 87 165 10.1 0.1 10.3 9.6 07/19/2006 08:00:00 13.6 1.8 19.1 9.1 13.9 1.9 19.5 9.5 13.2 1.6 18.3 9.5 78 9 80 165 10.1 0.1 10.9 9.6 07/19/2006 08:10:00 13.8 1.7 18.3 9.5 14.1 1.8 18.7 9.9 13.3 1.6 17.2 8.8 78 8 77 165 10.2 0.1 10.9 9.6 07/19/2006 08:20:00 13.2 1.9 17.9 8.4 13.4 1.9 18.3 8 12.7 1.7 17.2 8.8 77 8 78 165 10.2 0.2 10.6 9.6 07/19/2006 08:30:00 12.5 1.6 17.2 8 12.7 1.6 17.2 8 12.1 1.6 16.4 8.4 75 10 79 165 10.3 0.1 10.9 9.6 07/19/2006 08:40:00 10.9 1.7 15.6 7.2 11.1 1.7 16.4 7.6 10.7 1.7 15.6 7.2 74 9 84 165 10.2 0.2 10.6 9.6 07/19/2006 08:50:00 10.7 1.4 14.5 7.2 10.9 1.5 14.9 7.2 10.4 1.5 14.9 6.8 71 9 71 165 10.3 0.2 10.6 9.6 07/19/2006 09:00:00 10.7 2 17.9 6.8 10.9 2.1 17.9 6.5 10.3 1.9 16.8 5.7 70 10 74 165 10.3 0.1 10.6 9.6 07/19/2006 09:10:00 11 1.9 17.2 6.1 11.1 2 17.6 6.5 10.5 1.7 14.9 6.5 72 10 56 165 10.3 0.1 10.6 9.8 07/19/2006 09:20:00 10.7 1.7 14.9 5.7 10.9 1.8 15.3 5.7 10.3 1.6 14.9 6.1 73 9 63 165 10.3 0 10.6 9.8 07/19/2006 09:30:00 11.2 1.9 16.4 6.8 11.4 2 16.4 6.8 11.1 1.7 15.6 6.8 66 11 69 165 10.3 0.1 10.9 9.8 07/19/2006 09:40:00 11.3 2.3 17.2 6.1 11.4 2.4 17.6 6.5 11 2 16.8 6.8 66 10 65 165 10.3 0 10.9 9.6 07/19/2006 09:50:00 11 1.9 15.6 6.5 11.2 2 15.6 6.5 10.7 1.9 15.3 6.5 68 9 74 165 10.3 0 10.6 9.8 07/19/2006 10:00:00 10.8 1.8 15.6 6.5 11 1.9 15.6 6.5 10.6 1.7 14.9 6.8 71 10 65 165 10.3 0.1 10.6 9.8 07/19/2006 10:10:00 11.3 1.6 16.1 7.6 11.5 1.7 16.8 6.8 10.9 1.5 14.5 6.8 76 9 87 165 10.3 0.1 10.9 9.6 07/19/2006 10:20:00 12.1 1.7 17.6 8.4 12.3 1.7 17.9 8.4 11.7 1.6 17.2 7.2 76 8 84 165 10.3 0.1 10.6 9.8 07/19/2006 10:30:00 12.8 1.8 17.6 7.6 13.1 1.9 17.6 7.6 12.2 1.9 17.2 7.6 75 8 80 165 10.3 0.1 10.6 9.8 07/19/2006 10:40:00 12.5 1.8 16.8 8 12.8 1.9 16.8 8 12.1 1.7 16.4 8 76 8 85 165 10.4 0 11.1 9.8 07/19/2006 10:50:00 13.5 1.6 17.9 9.9 13.8 1.7 18.3 9.5 12.9 1.7 17.2 8.8 77 7 84 165 10.4 0 10.9 9.8 07/19/2006 11:00:00 13.1 1.7 18.7 9.1 13.4 1.7 19.5 8.8 12.7 1.6 17.2 8.4 78 8 80 165 10.5 0 10.6 10.1 07/19/2006 11:10:00 13.4 1.8 17.2 8.4 13.7 1.9 17.2 8.8 12.9 1.7 17.2 8 79 7 78 165 10.5 0 11.1 10.1 07/19/2006 11:20:00 13.8 1.6 18.3 9.5 14.1 1.7 19.1 9.5 13 1.7 18.3 8.8 78 7 84 165 10.5 0 10.9 10.1 07/19/2006 11:30:00 13 1.9 17.6 8 13.3 1.9 17.9 8 12.6 1.7 16.4 8 78 7 89 165 10.5 0 10.9 10.1 07/19/2006 11:40:00 13.2 1.6 17.9 9.5 13.4 1.7 18.7 9.5 12.4 1.6 16.4 8.4 78 8 72 165 10.5 0 10.9 10.1 07/19/2006 11:50:00 14.1 1.7 17.9 10.3 14.4 1.7 18.3 9.9 13.5 1.7 17.9 9.1 79 7 83 165 10.6 0.1 10.9 10.3 07/19/2006 12:00:00 12.1 1.7 16.1 7.6 12.4 1.7 16.4 8 11.7 1.6 16.1 8 77 8 86 165 10.6 0.1 10.9 10.3 07/19/2006 12:10:00 11.2 1.7 15.6 6.8 11.4 1.8 16.1 6.5 10.8 1.7 15.6 7.2 74 9 78 165 10.6 0.1 11.1 10.1 07/19/2006 12:20:00 10.9 1.6 14.9 6.5 11.1 1.7 15.3 6.8 10.6 1.5 14.1 6.8 72 8 81 165 10.6 0.1 10.9 10.1 07/19/2006 12:30:00 11.6 1.9 16.1 7.2 11.8 2 17.2 6.5 11.2 1.7 16.1 7.6 74 9 78 165 10.6 0.1 11.1 10.3 07/19/2006 12:40:00 11 1.7 16.1 6.8 11.2 1.7 16.4 6.8 10.8 1.5 14.9 7.2 75 9 77 165 10.6 0 10.9 10.3 07/19/2006 12:50:00 12.7 1.7 17.6 8.4 13 1.7 17.2 8 12.5 1.7 16.4 7.6 75 8 77 165 10.5 0 10.6 9.8 07/19/2006 13:00:00 12.8 1.7 16.8 8.4 13.1 1.8 17.2 8.8 12.2 1.7 16.4 7.2 74 8 84 165 10.5 0.1 10.9 10.1 07/19/2006 13:10:00 11.6 1.7 14.9 7.2 11.8 1.7 15.3 7.6 11.1 1.6 15.3 7.2 75 9 84 165 10.5 0.2 11.1 10.3 07/19/2006 13:20:00 12.6 1.8 17.9 8 12.9 1.9 18.3 8 12.1 1.7 16.4 7.6 76 8 84 165 10.5 0.2 10.9 10.3 07/19/2006 13:30:00 13.1 1.7 17.6 9.1 13.4 1.8 18.3 9.1 12.5 1.9 17.9 8.8 77 8 78 165 10.6 0.2 10.9 10.3 07/19/2006 13:40:00 12.4 1.8 17.2 8.4 12.7 1.9 17.6 8.4 12 1.7 16.8 8 75 8 68 165 10.7 0.1 11.1 10.3 07/19/2006 13:50:00 11.7 1.9 16.8 8 11.9 1.9 17.2 8 11.2 1.7 15.3 7.6 74 10 81 165 10.7 0.1 11.1 10.3 07/19/2006 14:00:00 10.9 1.9 16.4 6.5 11.1 2.1 16.8 6.1 10.6 1.9 16.1 6.5 73 9 71 165 10.7 0.1 11.1 10.3 07/19/2006 14:10:00 11.2 1.5 15.3 8 11.3 1.6 15.3 8 10.6 1.5 14.1 7.2 71 10 68 165 10.8 0.1 11.1 10.6 07/19/2006 14:20:00 11.5 2.2 16.1 6.5 11.7 2.3 16.8 6.5 11.1 2.1 16.8 7.6 68 10 72 165 10.8 0 11.1 10.3 07/19/2006 14:30:00 10.7 1.8 15.6 6.1 10.8 1.9 16.1 5.7 10.2 1.8 14.9 6.1 70 10 59 165 10.7 0.1 11.4 10.3 07/19/2006 14:40:00 11.1 2.1 16.4 6.5 11.2 2.2 16.8 6.1 10.5 2.1 15.6 5.3 65 12 63 165 10.7 0.1 10.9 10.3 07/19/2006 14:50:00 10.5 1.8 16.4 6.8 10.6 1.8 17.2 6.8 10 1.7 15.3 6.5 67 10 88 165 10.7 0.1 10.9 10.3 07/19/2006 15:00:00 9.8 2.3 16.8 4.9 9.8 2.4 16.8 4.9 9.4 2.1 14.5 5.3 63 10 43 165 10.7 0.1 11.1 10.3 07/19/2006 15:10:00 10.9 1.7 16.1 6.8 11 1.8 16.4 6.8 10.5 1.7 14.9 6.5 64 9 70 165 10.7 0.1 10.9 10.3 07/19/2006 15:20:00 10 1.7 14.9 6.1 10.1 1.7 15.3 5.7 9.6 1.7 13.7 5.3 62 12 78 165 10.7 0.1 10.9 10.3 07/19/2006 15:30:00 10.3 2.1 15.6 5.7 10.4 2.3 15.6 5.7 9.8 2.1 16.4 5.7 63 12 62 165 10.7 0 11.1 10.3 07/19/2006 15:40:00 9.6 2.2 15.3 4.6 9.7 2.3 15.3 4.2 9.4 1.9 14.1 4.6 62 12 75 165 10.7 0 11.1 10.3 07/19/2006 15:50:00 9 2.2 15.6 4.9 8.9 2.4 16.1 4.6 8.6 1.9 15.6 4.9 58 14 58 165 10.7 0.1 11.1 10.3 07/19/2006 16:00:00 10.5 2 15.6 6.5 10.6 2.1 16.1 6.5 10.3 1.9 15.6 6.1 62 10 59 165 10.7 0 11.1 10.3 07/19/2006 16:10:00 9.8 2.1 15.6 5.7 9.8 2.2 15.6 4.9 9.6 1.9 15.3 5.3 63 11 58 165 10.8 0 10.9 10.6 07/19/2006 16:20:00 10.4 2 16.8 5.7 10.4 2.1 17.2 5.7 9.8 1.9 16.1 4.9 63 11 65 165 10.8 0 10.9 10.6 07/19/2006 16:30:00 10 2 14.9 5.3 10.1 2.1 15.3 5.7 9.6 1.9 15.6 5.3 61 12 78 165 10.8 0 10.9 10.6 07/19/2006 16:40:00 10.4 1.8 15.6 5.7 10.4 2 16.1 5.7 9.8 1.7 15.6 6.1 57 12 53 165 10.8 0 11.4 10.6 07/19/2006 16:50:00 9.1 2.5 15.6 3.8 9.1 2.5 15.6 3.8 8.8 2.3 14.1 3.4 58 11 49 165 10.8 0 11.1 10.6 07/19/2006 17:00:00 9 2.3 14.1 3.8 9 2.4 14.1 3.8 8.6 2.3 14.1 3.8 54 12 67 165 10.8 0 11.1 10.6 07/19/2006 17:10:00 10.6 2 16.1 6.8 10.7 2.2 16.4 6.1 10 2 14.5 6.1 55 11 68 165 10.8 0 11.1 10.6 07/19/2006 17:20:00 8.2 2 14.1 4.2 8.1 2.1 14.5 4.2 7.7 1.9 13.3 3.8 57 12 65 165 10.7 0 10.9 10.3 07/19/2006 17:30:00 9 2.1 14.1 3.8 9 2.2 14.1 3.8 8.7 2 14.1 3.8 57 12 40 165 10.7 0.1 10.9 10.3 07/19/2006 17:40:00 8.6 1.9 14.1 4.9 8.5 2 14.5 4.9 8.2 1.7 13 4.9 56 11 50 165 10.7 0.1 11.1 10.3 07/19/2006 17:50:00 9.2 2.7 17.9 3.8 9.2 2.8 17.9 3.8 8.8 2.5 15.3 3.8 61 13 54 165 10.7 0.1 11.1 10.3 07/19/2006 18:00:00 8.1 1.9 13 4.2 8 2 13 4.2 7.9 1.9 13.3 3.8 55 12 58 165 10.6 0.2 11.1 10.3 07/19/2006 18:10:00 7.7 1.7 14.1 3.8 7.6 1.7 14.1 3.4 7.2 1.7 13.7 4.2 50 12 84 165 10.5 0.1 10.9 10.1 07/19/2006 18:20:00 7.2 1.3 10.7 4.6 7.1 1.3 10.7 4.2 7 1.2 9.9 4.2 47 10 44 165 10.3 0 10.6 9.8 07/19/2006 18:30:00 7.7 1.5 11.1 4.6 7.6 1.6 11.1 4.2 7.5 1.3 11.1 4.6 46 10 37 165 10.3 0 10.9 9.8 07/19/2006 18:40:00 9.3 1.7 13.7 4.6 9.2 1.8 13.7 4.2 8.6 1.6 13.7 4.6 46 10 55 165 10.4 0 10.9 9.8 07/19/2006 18:50:00 8.4 1.5 13.7 4.6 8.2 1.5 13.7 4.6 8 1.5 11.8 4.9 44 11 42 165 10.4 0 10.6 9.8 07/19/2006 19:00:00 8.5 1.5 13.7 4.9 8.4 1.5 14.1 4.9 8.1 1.5 13 4.6 46 10 49 165 10.4 0 10.6 9.8 07/19/2006 19:10:00 9.4 1.3 12.6 5.7 9.4 1.4 12.6 5.3 8.9 1.3 12.6 6.1 43 8 39 165 10.4 0 10.9 9.8 07/19/2006 19:20:00 9.1 1.1 11.5 6.1 9 1.2 11.5 5.7 8.6 1.1 12.2 4.9 43 8 44 165 10.5 0.1 10.9 10.1 07/19/2006 19:30:00 9.5 1.3 13 5.7 9.4 1.4 13 5.3 8.9 1.3 12.6 5.7 44 7 43 165 10.5 0.1 11.1 10.1 07/19/2006 19:40:00 10 1.7 13.3 4.9 10 1.8 13.7 4.6 9.6 1.7 13 5.3 41 7 44 165 10.6 0.2 11.1 10.3 07/19/2006 19:50:00 10.3 1.5 13.7 6.5 10.2 1.5 13.7 5.7 9.8 1.5 14.1 5.7 40 7 41 165 10.7 0.1 10.9 10.3 07/19/2006 20:00:00 10.2 1.5 13.7 6.8 10.1 1.6 14.1 6.5 9.8 1.4 13.3 6.5 38 8 48 165 10.7 0.1 10.9 10.3 07/19/2006 20:10:00 10.5 1.3 14.1 6.5 10.4 1.4 14.5 5.7 10.2 1.5 14.1 6.8 38 8 20 165 10.7 0.1 10.9 10.3 07/19/2006 20:20:00 11.4 1.2 13.7 8 11.3 1.3 14.1 7.6 11.1 1.5 14.5 6.8 38 5 36 165 10.7 0.1 10.9 10.3 07/19/2006 20:30:00 10.9 1.3 14.1 6.8 10.8 1.3 13.7 6.8 10.5 1.2 13.3 7.2 38 6 40 165 10.7 0.1 10.9 10.3 07/19/2006 20:40:00 11.6 1.2 14.9 8.4 11.5 1.2 14.5 7.6 11.1 1.3 14.1 7.6 37 6 39 165 10.7 0.1 10.9 10.3 07/19/2006 20:50:00 12.3 1.1 14.9 8.8 12.3 1.2 14.9 8.8 12 1.3 15.3 8 37 6 43 165 10.7 0.1 10.9 10.3 07/19/2006 21:00:00 11.7 1.4 14.9 8.4 11.6 1.4 14.5 8.4 11.1 1.4 14.5 8 38 7 37 165 10.7 0.1 10.9 10.3 07/19/2006 21:10:00 11.8 1.5 15.6 8.8 11.7 1.5 15.6 8.4 11.2 1.5 15.6 7.6 41 7 36 165 10.7 0.1 11.1 10.3 07/19/2006 21:20:00 11.9 1.8 17.6 8 11.9 1.9 17.6 7.6 11.3 2 16.4 6.5 39 8 37 165 10.7 0.1 10.9 10.3 07/19/2006 21:30:00 11.8 1.5 15.6 6.8 11.7 1.5 15.6 6.5 11.2 1.5 16.4 7.6 40 7 43 165 10.7 0 10.9 10.3 07/19/2006 21:40:00 12 1.3 16.8 8 11.9 1.4 16.8 8 11.4 1.6 16.1 7.6 39 8 29 165 10.7 0.1 10.9 10.3 07/19/2006 21:50:00 12 1.6 15.6 7.2 11.9 1.7 15.3 6.8 11.4 1.6 15.3 7.2 39 7 45 165 10.7 0 10.9 10.3 07/19/2006 22:00:00 12.3 1.4 16.1 8.4 12.2 1.5 15.6 8.4 11.4 1.5 15.6 8 40 8 43 165 10.7 0.1 11.1 10.3 07/19/2006 22:10:00 13 1.5 16.4 9.1 12.9 1.5 16.4 9.1 12.2 1.7 16.1 8.4 41 7 36 165 10.8 0.1 11.1 10.6 07/19/2006 22:20:00 11 1.7 16.1 6.8 10.9 1.7 16.1 6.8 10.4 1.7 14.1 6.8 42 8 30 165 10.8 0 11.1 10.6 07/19/2006 22:30:00 12.2 1.9 16.4 7.2 12.1 1.9 16.8 7.2 11.3 1.7 16.1 7.6 42 9 50 165 10.9 0 11.1 10.6 07/19/2006 22:40:00 12.1 1.7 16.8 6.8 12 1.7 16.8 6.8 11.5 1.7 16.8 6.8 42 9 40 165 10.9 0 11.1 10.6 07/19/2006 22:50:00 12.8 1.5 16.1 8.8 12.7 1.5 16.4 8.4 12.1 1.6 16.4 8.4 41 8 41 165 10.8 0.1 11.1 10.6 07/19/2006 23:00:00 12.1 1.6 16.1 8 12 1.7 16.4 7.2 11.3 1.6 15.3 7.2 43 8 46 165 10.8 0.1 11.1 10.6 07/19/2006 23:10:00 12.2 1.9 16.4 7.2 12.1 1.9 16.4 6.8 11.8 1.9 16.1 6.5 40 8 43 165 10.8 0.1 11.1 10.6 07/19/2006 23:20:00 12.4 1.7 17.6 7.6 12.3 1.8 17.6 7.2 11.8 1.8 17.2 7.2 41 8 38 165 10.8 0.1 11.1 10.6 07/19/2006 23:30:00 11.4 1.5 15.3 7.6 11.2 1.5 14.9 7.6 10.9 1.5 14.1 7.2 40 9 43 165 10.8 0.1 11.1 10.6 07/19/2006 23:40:00 10.4 1.8 14.9 6.1 10.3 1.8 15.3 5.7 10.1 1.7 14.9 6.5 39 9 48 165 10.8 0 11.1 10.6 07/19/2006 23:50:00 11 1.6 14.9 7.2 10.9 1.6 14.5 6.5 10.6 1.5 15.3 7.2 38 9 54 165 10.8 0.1 11.1 10.6 07/20/2006 00:00:00 12.5 1.5 16.8 8.4 12.4 1.6 16.4 8 11.8 1.6 16.1 8 38 8 41 165 10.8 0.1 11.1 10.3 07/20/2006 00:10:00 11.9 1.7 16.1 6.8 11.8 1.7 16.1 7.2 11.5 1.7 15.3 7.2 38 9 26 165 10.7 0.1 11.1 10.3 07/20/2006 00:20:00 12.3 1.9 16.8 8 12.1 2 17.2 7.6 11.6 2.1 16.1 6.8 37 9 46 165 10.9 0 11.1 10.6 07/20/2006 00:30:00 12.2 2 16.8 7.2 12.1 2.1 17.2 7.2 11.7 1.9 16.4 7.6 37 9 41 165 10.8 0 11.4 10.6 07/20/2006 00:40:00 12.7 1.9 17.6 7.2 12.5 2 17.6 6.8 11.9 2 17.6 6.8 35 9 37 165 10.7 0 11.1 10.3 07/20/2006 00:50:00 12.3 2.1 17.6 7.2 12.1 2.2 17.6 6.8 11.7 1.9 16.8 6.8 33 9 25 165 10.7 0.1 10.9 10.3 07/20/2006 01:00:00 13.1 2 19.9 7.6 12.9 2.1 19.9 7.6 12.4 2 18.3 7.6 30 10 44 165 10.7 0 10.9 10.3 07/20/2006 01:10:00 13.9 2.3 19.5 8.4 13.6 2.4 18.7 8 13.3 2.2 18.7 8 28 9 28 165 10.7 0.1 10.9 10.3 07/20/2006 01:20:00 13.7 1.9 17.6 8.8 13.4 2.1 17.9 7.2 12.8 2.1 17.6 8.4 27 9 36 165 10.7 0.1 10.9 10.3 07/20/2006 01:30:00 13.4 2.1 19.9 8.4 12.8 2.1 18.7 7.2 12.7 2.1 18.3 7.6 23 9 16 165 10.7 0.1 10.9 10.3 07/20/2006 01:40:00 13.6 1.8 17.9 8.8 13.1 2 17.9 7.2 13 2 17.6 8.4 23 9 25 165 10.5 0 10.9 10.3 07/20/2006 01:50:00 13.4 1.9 18.3 8.4 13 2 18.3 8 12.6 2 17.9 7.6 24 8 10 165 10.5 0 10.6 10.1 07/20/2006 02:00:00 14.2 2 20.2 9.5 13.7 2.2 19.1 8.4 13.7 2.2 20.2 7.6 22 8 12 165 10.4 0 10.6 9.8 07/20/2006 02:10:00 15.4 1.7 19.1 11.1 14.7 1.9 18.7 8.8 14.7 1.9 19.1 9.9 21 8 27 165 10.3 0 10.6 9.8 07/20/2006 02:20:00 14.4 2.2 18.7 8.4 13.6 2.5 18.3 6.1 13.9 2.3 18.7 8.8 18 9 19 165 10.3 0 10.6 9.8 07/20/2006 02:30:00 15.5 2.2 20.2 10.3 14.7 2.4 19.5 8.8 14.7 2.2 19.9 9.5 19 8 16 165 10.2 0.1 10.9 9.8 07/20/2006 02:40:00 14.6 2.2 19.5 9.1 13.8 2.4 19.1 8 14 2.2 19.1 9.1 19 8 20 165 10.1 0.2 10.9 9.6 07/20/2006 02:50:00 15.2 1.7 19.1 10.7 14.2 1.9 18.7 9.1 14.6 1.7 18.7 9.5 17 8 12 165 10.1 0.2 10.3 9.6 07/20/2006 03:00:00 15.3 1.8 19.5 10.3 14.1 2.2 19.1 8.4 14.9 1.8 20.2 10.3 16 8 12 165 10.1 0.2 10.9 9.6 07/20/2006 03:10:00 15.1 1.9 19.9 9.9 14 2.3 19.5 8.8 14.6 2 20.2 9.9 17 8 25 165 10.2 0.2 10.6 9.6 07/20/2006 03:20:00 14.6 2.1 19.5 9.5 13.5 2.4 18.7 8 14 2 18.7 9.9 17 8 11 165 10.2 0.2 10.6 9.6 07/20/2006 03:30:00 15.4 1.8 21 11.5 14.1 2.1 19.5 9.1 14.6 1.9 19.5 10.3 17 8 22 165 10.2 0.2 10.6 9.6 07/20/2006 03:40:00 16.1 1.9 21 11.1 14.7 2.3 20.2 6.8 15.2 1.9 21 10.3 16 8 28 165 10.2 0.2 10.9 9.6 07/20/2006 03:50:00 16 1.9 21 11.5 14.8 2.3 19.9 9.1 15.5 1.8 20.6 11.5 16 7 13 165 10.2 0.2 10.9 9.6 07/20/2006 04:00:00 16.4 2.2 23.7 11.8 15.1 2.5 23.7 8.4 15.7 2.2 22.1 11.1 16 8 22 165 10.2 0.2 10.6 9.6 07/20/2006 04:10:00 15.8 2.1 21.8 10.7 14.4 2.4 19.9 8.4 15.2 2.1 19.9 10.7 15 9 5 165 10.1 0.2 10.9 9.6 07/20/2006 04:20:00 16.2 2.1 21.8 10.3 14.7 2.5 21.4 7.6 15.4 2.1 21.8 10.3 15 8 29 165 10.1 0.2 10.6 9.6 07/20/2006 04:30:00 16.7 2.2 22.6 10.3 15.5 2.5 21.4 7.6 15.9 2.2 22.1 9.5 17 8 31 165 10.1 0.2 10.9 9.6 07/20/2006 04:40:00 17.2 2.2 22.9 11.1 15.8 2.8 22.6 9.5 16.4 2.3 22.9 10.7 16 8 16 165 10.1 0.2 10.6 9.6 07/20/2006 04:50:00 16.5 2 21 11.5 15 2.4 20.2 9.5 15.8 2 21 11.5 15 8 26 165 10.1 0.2 10.3 9.6 07/20/2006 05:00:00 17 2.2 22.9 12.2 15.3 2.6 22.1 10.3 16.6 2.1 22.9 11.8 14 8 20 165 10.1 0.1 10.6 9.6 07/20/2006 05:10:00 18.6 2.1 24 14.1 17.1 2.5 22.6 10.3 17.6 2.2 23.3 12.2 16 7 19 165 10.1 0.2 10.9 9.6 07/20/2006 05:20:00 17 2.1 22.6 11.8 15.3 2.7 22.1 9.9 16.1 2.1 21.4 11.1 15 8 23 165 10.1 0.1 10.9 9.6 07/20/2006 05:30:00 17.8 2.1 23.7 12.6 16.3 2.6 23.7 9.9 17.3 2.2 22.6 11.5 16 8 25 165 10.1 0.1 10.3 9.6 07/20/2006 05:40:00 16.7 1.9 21.8 11.5 15.2 2.4 20.6 9.1 16 2.2 21.4 10.3 16 8 18 165 10.2 0.1 10.6 9.6 07/20/2006 05:50:00 17.9 2.3 22.9 11.5 16.4 2.6 21.8 10.7 17.5 2.4 24.4 12.2 16 8 14 165 10.2 0.1 10.6 9.6 07/20/2006 06:00:00 18 2.1 24 11.1 16.5 2.6 22.9 9.9 17.3 2.1 23.3 12.6 17 8 13 165 10.3 0 10.9 9.8 07/20/2006 06:10:00 17.8 2.3 22.6 11.5 16.6 2.5 22.6 9.1 17.3 2.4 22.9 11.8 16 7 20 165 10.4 0 10.6 9.8 07/20/2006 06:20:00 18 1.9 22.1 11.5 16.9 2.2 21.4 8.4 17.3 1.9 21.4 10.7 17 7 21 165 10.4 0 10.6 9.8 07/20/2006 06:30:00 18.6 2.1 23.7 13 17.8 2.4 23.3 12.2 18 2.3 24.8 12.2 21 7 22 165 10.6 0.1 10.9 10.1 07/20/2006 06:40:00 17.7 2 22.1 12.2 16.8 2.3 22.1 9.9 16.7 2.1 21.8 11.1 20 8 22 165 10.7 0.1 11.1 10.3 07/20/2006 06:50:00 17.4 2.4 22.6 12.6 16.5 2.6 22.6 10.3 16.4 2.4 22.9 11.1 21 8 24 165 10.7 0.1 10.9 10.3 07/20/2006 07:00:00 16.4 2.2 21.8 11.1 15.7 2.2 21 10.3 15.6 2.2 21.4 10.3 21 8 23 165 10.7 0.1 11.1 10.3 07/20/2006 07:10:00 16 2 22.1 9.5 15.3 2.3 21.8 9.5 15.4 2.3 21.4 8.8 21 9 25 165 10.6 0.2 11.1 10.3 07/20/2006 07:20:00 16.6 2.1 23.7 11.1 16 2.2 23.7 9.9 15.9 2.2 22.1 10.7 23 8 20 165 10.6 0.2 10.9 10.3 07/20/2006 07:30:00 15.6 2.2 20.6 9.5 15.1 2.3 20.6 8.4 15 2.3 21.8 9.9 24 8 35 165 10.6 0.2 10.9 10.3 07/20/2006 07:40:00 13.4 2.2 18.3 8.4 13 2.3 18.3 8.4 13 2.1 17.9 8.4 24 9 32 165 10.6 0.2 10.9 10.3 07/20/2006 07:50:00 14.4 2.1 19.9 9.1 14.2 2.3 19.5 8 13.9 2.1 19.1 9.1 29 9 36 165 10.6 0.2 10.9 10.3 07/20/2006 08:00:00 15.3 2.1 19.9 9.5 15.1 2.2 20.2 9.1 14.4 2.1 19.1 8.8 30 8 35 165 10.6 0.2 10.9 10.3 07/20/2006 08:10:00 14.7 2.2 19.5 8.4 14.5 2.3 19.1 8.4 14.1 2.4 18.7 8.4 30 9 39 165 10.6 0.2 11.1 10.3 07/20/2006 08:20:00 14.1 2.2 20.2 9.5 13.8 2.2 20.6 8.8 13.5 2.1 19.5 8.4 29 9 39 165 10.6 0.2 10.9 10.3 07/20/2006 08:30:00 15.3 2 19.9 10.3 15 2.1 20.2 9.9 14.7 2 20.6 9.5 30 8 37 165 10.6 0.2 11.1 10.3 07/20/2006 08:40:00 14.9 2.1 19.5 9.1 14.7 2.2 19.5 9.1 14.1 2.2 18.3 9.1 31 8 41 165 10.5 0.2 10.9 10.3 07/20/2006 08:50:00 14.5 2 19.1 9.5 14.3 2.1 19.1 9.5 13.9 2 19.1 9.1 30 8 32 165 10.5 0.2 11.1 10.3 07/20/2006 09:00:00 14.4 1.8 18.7 8.8 14.1 1.9 18.7 8.8 13.8 2 18.3 8.8 31 8 22 165 10.5 0.1 10.9 10.1 07/20/2006 09:10:00 13.8 1.8 17.9 8.8 13.6 1.9 17.9 8.4 13.3 1.9 17.6 8 32 8 36 165 10.5 0.1 11.1 10.1 07/20/2006 09:20:00 13.1 1.5 16.8 9.1 12.9 1.5 16.8 8.8 12.6 1.5 17.2 7.6 31 8 28 165 10.5 0.1 10.9 10.3 07/20/2006 09:30:00 12.6 1.6 16.4 8.4 12.4 1.7 16.4 8.4 12.1 1.5 16.4 8.4 30 8 27 165 10.5 0 10.9 10.3 07/20/2006 09:40:00 11.9 1.7 16.8 7.6 11.7 1.7 17.2 7.2 11.3 1.7 16.4 6.5 30 9 32 165 10.6 0 10.9 10.3 07/20/2006 09:50:00 11.9 1.7 16.8 7.6 11.8 1.7 16.8 7.2 11.6 1.7 16.4 6.5 33 8 35 165 10.5 0 11.1 10.3 07/20/2006 10:00:00 11.4 1.5 14.9 6.8 11.3 1.5 14.9 6.8 11 1.5 14.9 7.2 34 8 39 165 10.5 0 10.9 10.3 07/20/2006 10:10:00 11.5 1.5 16.4 8.4 11.4 1.5 16.1 7.6 11.3 1.6 16.4 8 34 7 36 165 10.6 0.1 10.9 10.3 07/20/2006 10:20:00 10.4 1.5 15.3 6.1 10.2 1.5 15.3 4.9 10 1.5 14.1 5.7 36 8 40 165 10.7 0.2 10.9 10.3 07/20/2006 10:30:00 9.2 1.3 13 5.3 9 1.5 12.6 4.9 9 1.3 13 5.3 38 9 39 165 10.7 0.2 10.9 10.3 07/20/2006 10:40:00 7.6 1.3 11.5 4.9 7.4 1.3 11.8 4.6 7.4 1.1 10.7 4.6 42 10 43 165 10.7 0.1 10.9 10.3 07/20/2006 10:50:00 7.6 1.3 11.5 4.2 7.5 1.5 11.8 4.2 7.5 1.3 11.8 4.6 47 11 57 165 10.7 0 11.1 10.3 07/20/2006 11:00:00 7.1 1.3 10.7 4.2 7 1.4 11.1 4.2 6.8 1.5 11.1 3.4 59 11 57 165 10.9 0 11.1 10.3 07/20/2006 11:10:00 7.3 1.5 10.7 4.2 7.3 1.5 11.1 4.2 7.1 1.3 10.7 4.6 66 10 59 165 11.1 0 11.4 10.9 07/20/2006 11:20:00 6.5 1.2 9.5 3.8 6.5 1.2 9.5 3.8 6.5 1.1 9.9 4.2 82 9 81 165 10.9 0.1 11.4 10.3 07/20/2006 11:30:00 6.7 1 9.5 4.2 6.7 1 9.5 4.6 6.6 1 10.3 4.6 78 9 94 165 10.5 0 11.1 9.8 07/20/2006 11:40:00 7.2 0.9 9.1 4.9 7.3 1 9.9 4.6 7 0.8 9.1 4.6 82 8 104 165 10.4 0 10.9 9.8 07/20/2006 11:50:00 8 1.1 10.7 5.3 8.1 1.2 10.7 5.3 7.8 1.1 10.3 5.3 85 8 87 165 10.5 0.1 10.9 10.1 07/20/2006 12:00:00 5.1 0.7 7.2 3.8 5.1 0.7 7.6 3.4 5 0.7 7.2 3.4 73 10 54 165 10.7 0.1 11.1 10.3 07/20/2006 12:10:00 5.3 0.9 8 3.4 5.4 0.9 8 3.4 5.4 0.9 7.6 3.4 80 11 65 165 10.9 0 11.1 10.6 07/20/2006 12:20:00 5.9 0.9 8.8 3.8 6 0.9 9.1 4.2 6.1 1 9.1 3.8 81 9 90 165 10.7 0 10.9 10.6 07/20/2006 12:30:00 5.9 1 8.8 3.8 6 1 9.5 4.2 5.8 1 9.5 3.4 78 13 73 165 10.8 0 11.1 10.3 07/20/2006 12:40:00 5.8 1 9.1 3.8 5.9 1.1 9.1 3.8 5.9 1 8.8 3.8 69 11 61 165 10.8 0 11.1 10.3 07/20/2006 12:50:00 6.9 1.2 9.5 3.4 7 1.3 9.9 3.4 6.8 1.2 9.9 4.2 66 9 68 165 10.7 0.2 11.4 10.3 07/20/2006 13:00:00 6.6 1.4 10.3 3.4 6.6 1.5 10.7 3.4 6.5 1.3 10.3 3.8 62 12 65 165 10.7 0.3 11.1 10.1 07/20/2006 13:10:00 5.9 1.4 9.1 3 5.8 1.5 9.5 3 5.9 1.4 9.5 3 55 13 59 165 10.6 0.3 11.1 10.1 07/20/2006 13:20:00 5.3 0.8 7.2 3 5.3 0.9 7.6 3 5.3 0.9 7.6 3 56 9 65 165 10.4 0.1 10.9 9.8 07/20/2006 13:30:00 5.7 1 8.4 3.4 5.7 1 8.4 3.4 5.7 1 8.8 3.4 51 10 52 165 10.3 0 10.6 9.8 07/20/2006 13:40:00 6.8 0.9 8.8 4.6 6.7 1 8.8 4.6 6.5 1 8.4 3.8 50 6 46 165 10.2 0 10.6 10.1 07/20/2006 13:50:00 6.5 1 8.8 3.4 6.4 1 8.8 3.4 6.3 0.9 8.4 3.8 50 7 48 165 10.1 0 10.6 10.1 07/20/2006 14:00:00 5.9 0.9 8 3.8 5.8 1 8 3.8 5.6 0.8 7.6 3.8 48 9 43 165 10.3 0 10.6 10.1 07/20/2006 14:10:00 6.8 0.8 8.8 4.6 6.7 0.9 8.8 4.6 6.4 0.8 8.4 3.8 50 8 51 165 10.2 0 10.6 9.8 07/20/2006 14:20:00 7.1 0.9 8.8 4.6 7 1 9.1 4.2 6.7 1 8.8 3.4 51 7 45 165 10.2 0 10.6 9.8 07/20/2006 14:30:00 6.2 1 9.5 3.8 6.1 1 9.1 3.8 6 0.9 8.4 3.8 51 9 57 165 10.3 0 10.6 10.1 07/20/2006 14:40:00 5.5 1 8 3 5.4 1.1 8 2.6 5.3 1 8 3 52 10 55 165 10.4 0 10.6 10.1 07/20/2006 14:50:00 6.6 1.2 9.5 4.2 6.6 1.2 9.9 4.2 6.2 1.1 9.5 3.8 55 11 49 165 10.4 0 10.6 10.1 07/20/2006 15:00:00 5.9 1.2 8.8 3.4 5.8 1.2 8.4 3.4 5.8 1.1 8.8 3.4 54 12 56 165 10.3 0 10.6 10.1 07/20/2006 15:10:00 5.6 1.1 8.8 3.4 5.5 1.1 8.4 3 5.4 1 8.8 2.6 53 12 66 165 10.3 0 10.6 10.1 07/20/2006 15:20:00 6 1.2 9.5 3.4 6 1.3 9.9 3.4 5.8 1.1 9.5 3.4 56 14 63 165 10.3 0 10.6 10.1 07/20/2006 15:30:00 5.6 1 8.8 3 5.6 1 9.1 3 5.4 0.9 8 3.4 53 11 63 165 10.3 0 10.6 10.1 07/20/2006 15:40:00 5.9 1.2 9.9 3.4 5.8 1.2 9.9 3.4 5.7 1 9.1 3.4 58 13 71 165 10.3 0.1 10.6 10.1 07/20/2006 15:50:00 5.5 1.1 8.4 2.3 5.4 1.1 8.8 2.3 5.5 1 8.8 3.4 49 13 88 165 10.3 0.1 10.6 9.8 07/20/2006 16:00:00 6.1 1.2 10.3 3.8 6 1.2 10.3 3.8 5.9 1.2 8.8 3.4 45 8 46 165 10.1 0.2 10.6 9.6 07/20/2006 16:10:00 6.7 1.1 9.9 3.4 6.6 1.2 9.9 3.4 6.4 1.1 9.5 4.2 46 11 49 165 10 0.2 10.6 9.6 07/20/2006 16:20:00 5.8 1.1 8.8 3.4 5.7 1.1 8.4 3 5.6 1 8.4 3.4 48 10 53 165 10.1 0.2 10.6 9.6 07/20/2006 16:30:00 6.9 1.3 9.9 3 6.8 1.3 9.9 3 6.6 1.2 9.5 3.4 47 9 57 165 10 0.2 10.6 9.6 07/20/2006 16:40:00 7 1.1 9.9 3.8 6.9 1.1 10.3 4.2 6.8 1 10.7 4.6 48 10 70 165 10.1 0.2 10.6 9.6 07/20/2006 16:50:00 7.7 1 10.3 4.9 7.6 1.1 10.3 4.9 7.6 1 9.9 5.3 43 7 36 165 10 0.3 10.3 9.6 07/20/2006 17:00:00 6.7 1.1 9.5 4.2 6.6 1.1 9.5 3.8 6.5 1 9.5 4.2 44 10 56 165 10 0.2 10.3 9.6 07/20/2006 17:10:00 6.7 1.1 9.5 4.2 6.5 1.2 9.5 4.2 6.6 1 9.1 3.4 45 9 37 165 10.1 0.2 10.6 9.6 07/20/2006 17:20:00 7.1 1.3 9.9 3.8 7 1.3 9.9 3.8 6.9 1.1 9.5 3.8 45 8 46 165 10 0.2 10.6 9.6 07/20/2006 17:30:00 7.1 1.3 10.7 3.8 7 1.3 10.3 3.8 6.9 1.1 10.3 4.2 47 9 37 165 10.1 0.2 10.6 9.6 07/20/2006 17:40:00 7.1 1.3 11.5 4.2 7 1.4 11.5 4.2 7 1.4 11.8 4.2 45 10 41 165 10.1 0.2 10.6 9.6 07/20/2006 17:50:00 6.4 1.2 10.3 3.8 6.3 1.3 10.7 3.8 6.2 1.2 10.3 3.4 51 12 63 165 10.1 0.2 10.6 9.6 07/20/2006 18:00:00 6.7 1.2 9.5 4.2 6.5 1.3 9.9 3.8 6.3 1.1 8.8 3.8 50 11 61 165 10.1 0.1 10.6 9.8 07/20/2006 18:10:00 6.5 1.5 10.7 3.4 6.4 1.6 11.1 3 6.1 1.3 10.3 3.8 50 13 62 165 10.2 0.1 10.6 9.8 07/20/2006 18:20:00 6.8 1.5 11.5 3.8 6.7 1.5 11.5 3.8 6.5 1.4 11.5 3.8 49 12 50 165 10.3 0 10.6 9.8 07/20/2006 18:30:00 7.3 1.7 11.1 3.8 7.2 1.7 11.5 3.8 7 1.7 12.6 3.8 51 13 61 165 10.2 0.1 10.9 9.8 07/20/2006 18:40:00 6.7 1.7 11.8 3 6.7 1.7 12.2 3.4 6.4 1.6 10.7 3.4 49 13 46 165 10.1 0 10.6 9.8 07/20/2006 18:50:00 6.4 1.2 9.9 3.8 6.3 1.2 9.9 3.8 6.1 1.1 8.8 3.4 45 9 54 165 10 0.2 10.3 9.6 07/20/2006 19:00:00 7 1.5 11.5 2.6 6.9 1.5 10.7 3 6.8 1.3 9.9 3.8 46 10 55 165 10 0.2 10.3 9.8 07/20/2006 19:10:00 6 1.4 10.7 3 6 1.4 10.7 3 5.9 1.3 10.3 3 50 13 54 165 10 0.2 10.6 9.6 07/20/2006 19:20:00 6.8 1.3 10.7 3.8 6.6 1.3 10.3 3.8 6.6 1.2 10.3 3.8 45 10 43 165 10.1 0.1 10.3 9.6 07/20/2006 19:30:00 6.6 1.2 9.9 3.4 6.6 1.3 9.9 3.8 6.4 1.1 8.8 3.4 50 12 61 165 10 0.2 10.6 9.6 07/20/2006 19:40:00 6.7 1.5 11.8 3.8 6.7 1.5 11.8 3.8 6.4 1.3 10.3 3.4 56 11 46 165 10.1 0.2 10.6 9.6 07/20/2006 19:50:00 6.9 1.2 9.5 3.8 6.8 1.2 9.9 3.8 6.5 1.3 9.5 3.4 52 11 62 165 10.2 0 10.6 9.8 07/20/2006 20:00:00 7.5 1.7 12.2 3.8 7.5 1.8 11.5 3.8 7.4 1.7 11.5 4.2 57 12 47 165 10.3 0 10.6 9.8 07/20/2006 20:10:00 7.6 1.7 11.5 3.8 7.7 1.7 11.8 3.8 7.2 1.7 11.8 3.8 58 10 56 165 10.3 0 10.6 10.1 07/20/2006 20:20:00 5.9 1.1 9.1 3.8 5.9 1.1 9.5 3.8 5.6 1 8.4 3.4 51 12 80 165 10.2 0 10.6 9.8 07/20/2006 20:30:00 6.7 1.4 9.9 3 6.7 1.4 10.3 3.4 6.5 1.3 10.3 3.4 57 11 70 165 10.3 0 10.6 10.1 07/20/2006 20:40:00 6.9 1.7 12.2 3 6.9 1.7 12.2 3.4 6.7 1.5 11.5 3.8 61 12 69 165 10.3 0 10.9 10.1 07/20/2006 20:50:00 7.2 1.5 11.1 3.4 7.2 1.5 11.5 3.8 7.1 1.4 11.1 4.2 61 13 88 165 10.4 0 10.9 10.3 07/20/2006 21:00:00 5.7 1.1 8.8 3 5.7 1.1 8.8 3 5.6 1 8.8 3.8 45 9 43 165 10.1 0.1 10.6 9.8 07/20/2006 21:10:00 5.8 1.1 9.5 3 5.7 1.1 9.9 2.6 5.7 1 8.8 3 49 11 52 165 10.1 0.1 10.3 9.8 07/20/2006 21:20:00 6.3 1.5 10.3 3 6.3 1.5 10.3 3.4 6.1 1.4 9.5 3.4 56 12 61 165 10.2 0 10.6 9.8 07/20/2006 21:30:00 6.7 1.5 11.5 3.8 6.7 1.5 11.5 3.4 6.5 1.4 11.1 3.4 55 12 59 165 10.3 0 10.6 10.3 07/20/2006 21:40:00 5.7 1.3 9.1 2.6 5.7 1.3 9.1 3 5.6 1.2 8.8 2.6 48 13 52 165 10.2 0 10.6 10.1 07/20/2006 21:50:00 5.3 1.1 8.8 3 5.3 1.1 8.8 2.6 5.2 1 8 2.6 53 13 37 165 10.3 0 10.6 10.1 07/20/2006 22:00:00 5.8 1.5 10.7 3.4 5.8 1.6 10.7 3 5.6 1.3 9.9 3 53 12 62 165 10.3 0 10.6 10.1 07/20/2006 22:10:00 6.1 1 8.8 3.8 6.1 1 9.1 3.8 5.9 0.9 9.1 3.8 48 10 64 165 10.2 0.1 10.6 9.8 07/20/2006 22:20:00 6.2 1.7 11.1 3.4 6.2 1.7 11.5 3.4 6 1.5 12.2 3 57 13 53 165 10.3 0 10.6 10.1 07/20/2006 22:30:00 6.1 1.5 10.7 3 6.1 1.5 11.1 2.6 5.9 1.3 9.5 3.4 55 12 88 165 10.3 0 10.6 10.1 07/20/2006 22:40:00 6.7 1.9 11.5 2.3 6.7 2 11.8 2.3 6.4 1.8 12.2 2.6 59 13 65 165 10.3 0 10.6 10.3 07/20/2006 22:50:00 6.7 1.4 10.7 4.2 6.7 1.5 10.7 3.8 6.7 1.3 10.7 3.8 62 13 74 165 10.5 0 10.9 10.3 07/20/2006 23:00:00 7.3 1.7 11.1 3.4 7.4 1.7 11.5 3 7.1 1.7 11.5 3.4 59 14 68 165 10.4 0 10.9 9.8 07/20/2006 23:10:00 7.4 1.5 11.5 4.2 7.4 1.7 11.8 4.2 7.2 1.4 11.1 4.2 62 11 73 165 10.4 0 10.9 9.8 07/20/2006 23:20:00 6.9 1.5 11.1 3 6.9 1.5 11.5 3.8 6.6 1.2 10.7 4.2 61 12 57 165 10.4 0 10.6 10.1 07/20/2006 23:30:00 8.3 1.1 11.5 5.7 8.4 1.2 11.8 5.7 8.1 1.1 11.5 4.9 66 11 79 165 10.4 0 10.6 9.8 07/20/2006 23:40:00 7.7 1.5 11.8 3.8 7.8 1.5 11.8 4.2 7.5 1.5 12.2 4.2 67 9 73 165 10.4 0 10.9 10.1 07/20/2006 23:50:00 6.7 1.2 10.7 3.8 6.7 1.3 10.7 4.2 6.3 1.1 9.9 4.2 64 11 54 165 10.4 0 10.6 9.8 07/21/2006 00:00:00 7.2 1 9.9 4.6 7.3 1.1 10.3 4.6 7.2 1.1 9.5 4.6 69 8 63 165 10.4 0 10.6 9.8 07/21/2006 00:10:00 7.3 1.3 11.8 4.2 7.5 1.4 11.8 4.2 7.3 1.2 10.7 3.8 70 10 68 165 10.4 0 10.6 9.8 07/21/2006 00:20:00 7 1.3 11.5 4.2 7.1 1.4 11.8 4.2 7 1.3 11.8 4.2 76 10 94 165 10.4 0 10.6 9.8 07/21/2006 00:30:00 6.6 1.2 9.9 3.8 6.6 1.2 10.3 3.8 6.4 1.2 9.9 3.8 67 10 87 165 10.4 0 10.6 9.8 07/21/2006 00:40:00 6.8 1.1 9.9 4.6 6.9 1.1 9.9 4.6 6.8 1 9.9 4.6 68 10 58 165 10.3 0 10.6 9.8 07/21/2006 00:50:00 6.7 1 9.1 4.6 6.7 1.1 9.9 4.2 6.5 1 8.8 4.2 70 10 62 165 10.3 0 10.6 9.8 07/21/2006 01:00:00 5.6 0.9 8 3.4 5.7 0.9 8 3.8 5.5 1 7.6 3.4 70 10 78 165 10.3 0 10.6 9.8 07/21/2006 01:10:00 5.8 1 8.4 3.8 6 1 8.4 3.8 5.8 1 8 3.8 68 11 46 165 10.4 0 10.6 9.8 07/21/2006 01:20:00 4.9 1 7.6 2.3 5 1.1 8 3 5 1 8 3 67 12 81 165 10.4 0 10.6 10.1 07/21/2006 01:30:00 4.6 1.4 8.8 1.9 4.8 1.5 8.8 2.3 4.7 1.3 9.1 1.9 63 11 72 165 10.3 0 10.6 10.3 07/21/2006 01:40:00 4.1 1.5 9.1 1.9 4.2 1.5 9.5 1.9 4.2 1.2 8 2.3 61 12 67 165 10.3 0 10.6 10.3 07/21/2006 01:50:00 4.4 1 6.8 1.5 4.5 1 6.8 1.5 4.4 0.8 6.5 2.6 60 13 65 165 10.2 0 10.6 10.3 07/21/2006 02:00:00 4.6 1.1 7.6 2.3 4.7 1.1 7.6 2.3 4.5 0.9 6.8 1.5 56 13 56 165 10.2 0 10.6 10.3 07/21/2006 02:10:00 4.8 1 7.6 3 4.9 1 7.6 3 4.7 1 7.6 2.6 57 11 65 165 10.2 0 10.6 10.1 07/21/2006 02:20:00 5 1.5 9.5 2.3 5 1.5 9.5 2.3 4.9 1.2 8.8 2.6 57 14 70 165 10.2 0 10.6 10.1 07/21/2006 02:30:00 5 1.1 8 2.6 5 1.2 8.4 2.6 5 1.1 8 3 59 13 52 165 10.3 0 10.6 10.3 07/21/2006 02:40:00 5.1 1 8.4 2.6 5.2 1 8.4 2.6 5 0.8 7.2 3 61 11 69 165 10.3 0 10.6 10.3 07/21/2006 02:50:00 4.9 1.1 8 2.6 5 1.1 7.6 2.6 4.8 0.9 7.2 2.6 61 12 87 165 10.3 0 10.6 10.3 07/21/2006 03:00:00 4.8 1.1 7.6 2.3 4.9 1.1 7.6 2.3 4.7 0.9 7.2 2.3 60 13 61 165 10.3 0 10.6 10.3 07/21/2006 03:10:00 5.6 1.3 8.4 1.9 5.6 1.3 8.8 2.3 5.5 1.1 8 2.6 64 12 64 165 10.3 0 10.6 10.3 07/21/2006 03:20:00 5.2 1.2 7.6 1.9 5.3 1.2 7.6 1.9 5.1 1.1 8 2.3 62 12 85 165 10.3 0 10.6 10.3 07/21/2006 03:30:00 4.7 1 7.6 2.6 4.7 1.1 8 2.6 4.6 1 7.6 2.6 56 15 69 165 10.2 0 10.6 10.3 07/21/2006 03:40:00 4.7 1.2 8.8 2.3 4.8 1.2 8.8 2.3 4.7 1 8 2.6 56 12 54 165 10.1 0.1 10.3 9.6 07/21/2006 03:50:00 4.7 1.1 9.1 2.6 4.7 1.2 9.5 2.6 4.5 1 8 3 57 14 54 165 10.1 0.1 10.3 9.6 07/21/2006 04:00:00 5.2 1.1 8 2.3 5.3 1.2 8 2.3 5.3 1.1 8 2.6 61 11 78 165 10.2 0 10.6 9.8 07/21/2006 04:10:00 5.6 1.1 8.4 3 5.7 1.2 8.8 2.6 5.5 1.1 8 3 64 11 70 165 10.2 0 10.6 9.8 07/21/2006 04:20:00 5.2 1.2 9.1 2.3 5.3 1.2 9.1 2.3 5.1 1.1 7.6 2.6 66 13 91 165 10.3 0 10.6 10.1 07/21/2006 04:30:00 6.1 0.9 8.4 3.8 6.3 0.9 8.8 4.2 6 0.9 8.4 3.8 73 9 70 165 10.3 0 10.6 10.1 07/21/2006 04:40:00 6.7 1.3 9.9 4.2 6.8 1.3 10.3 4.2 6.5 1.1 9.5 4.2 71 8 65 165 10.3 0 10.6 10.1 07/21/2006 04:50:00 6.5 1.1 10.3 4.2 6.7 1.1 11.1 4.2 6.5 1.1 10.3 4.2 71 9 65 165 10.3 0 10.6 10.1 07/21/2006 05:00:00 6.1 1 8.4 3.4 6.2 1 8.8 3.8 5.9 1 8 3.8 70 9 62 165 10.2 0 10.6 9.8 07/21/2006 05:10:00 6.6 1 9.9 3.8 6.7 1.1 9.9 4.2 6.4 1.1 9.9 3.8 67 9 81 165 10.2 0 10.6 9.8 07/21/2006 05:20:00 6.4 1.1 9.5 3.8 6.5 1.1 9.9 4.2 6.4 1.1 9.9 4.6 66 9 70 165 10.2 0 10.6 9.8 07/21/2006 05:30:00 6.1 1 9.1 3.4 6.1 1 9.1 3.4 5.8 0.9 9.1 3.8 64 9 62 165 10.3 0 10.6 9.8 07/21/2006 05:40:00 6.4 1.1 9.1 3.8 6.5 1.1 9.5 3.8 6.3 1.1 9.1 3.8 65 11 65 165 10.3 0 10.6 10.1 07/21/2006 05:50:00 5.6 1 8 3 5.7 1 8 3.4 5.6 1 8.4 3.4 70 10 57 165 10.3 0 10.6 9.8 07/21/2006 06:00:00 6.1 1 8.4 4.2 6.2 1 8.4 4.2 6 1 8.8 3.8 72 9 78 165 10.2 0 10.6 10.3 07/21/2006 06:10:00 5.7 1.1 8.8 3.4 5.8 1.2 8.8 3.4 5.6 1 8.4 3.4 65 9 74 165 10.3 0 10.6 10.3 07/21/2006 06:20:00 6.1 0.8 8.4 4.2 6.2 0.9 8.8 3.8 6 0.9 8.8 3.8 67 10 59 165 10.3 0 10.6 10.3 07/21/2006 06:30:00 5.9 0.9 8.4 3.8 6.1 0.9 8.8 3.8 5.8 0.8 7.6 3.8 72 9 56 165 10.3 0 10.6 10.3 07/21/2006 06:40:00 5.9 1.1 9.5 3.4 6 1.1 9.1 3.8 5.8 1 9.1 3.8 73 10 74 165 10.3 0 10.6 10.3 07/21/2006 06:50:00 5.5 0.8 8 3.4 5.6 0.9 8 3.4 5.5 0.8 8 3.4 73 9 70 165 10.3 0 10.6 10.3 07/21/2006 07:00:00 6.7 1.5 10.3 4.2 6.9 1.5 10.7 4.2 6.5 1.3 9.9 3.8 78 11 71 165 10.3 0 10.6 10.3 07/21/2006 07:10:00 7.2 1.2 9.9 3.8 7.4 1.2 10.3 3.8 7 1.1 9.9 4.9 78 11 80 165 10.3 0 10.6 10.3 07/21/2006 07:20:00 6.1 1.1 9.5 4.2 6.2 1.1 9.5 4.2 6 1 8.8 3.8 74 10 75 165 10.3 0 10.6 10.3 07/21/2006 07:30:00 6.2 1 8.8 4.2 6.3 1 8.8 4.2 6.1 0.9 8.8 3.8 73 11 75 165 10.3 0 10.6 10.3 07/21/2006 07:40:00 6.4 1.2 9.5 3.8 6.6 1.3 9.1 3.8 6.1 1.1 8.8 3.8 76 10 81 165 10.3 0 10.6 10.3 07/21/2006 07:50:00 6.6 1.3 10.3 3.4 6.6 1.4 10.7 3 6.4 1.2 9.5 3.4 75 11 71 165 10.3 0 10.6 10.3 07/21/2006 08:00:00 6.9 1.3 11.5 3.8 7.1 1.3 11.8 3.8 6.9 1.2 10.7 4.2 78 10 85 165 10.3 0 10.6 10.3 07/21/2006 08:10:00 7.7 1.3 11.5 4.9 7.9 1.4 11.5 4.9 7.6 1.3 11.1 4.6 80 8 82 165 10.3 0 10.6 10.3 07/21/2006 08:20:00 7 1.1 10.3 4.6 7.1 1.1 10.7 4.6 6.9 1 9.9 4.6 77 9 78 165 10.3 0 10.6 10.3 07/21/2006 08:30:00 7.4 1.2 10.7 4.9 7.6 1.2 10.7 4.6 7.3 1.1 10.7 4.9 79 9 82 165 10.4 0 10.6 10.3 07/21/2006 08:40:00 6.8 1.3 11.1 4.2 7.1 1.3 11.1 4.6 7 1.3 11.5 4.2 78 10 90 165 10.4 0 10.6 10.1 07/21/2006 08:50:00 7.8 1.2 10.7 4.9 8.1 1.2 11.1 5.3 7.7 1.1 10.7 5.3 80 8 87 165 10.4 0 10.6 9.8 07/21/2006 09:00:00 8.8 1.1 12.2 6.1 9 1.1 12.2 6.5 8.5 1.1 10.7 5.7 83 8 87 165 10.4 0 10.6 10.3 07/21/2006 09:10:00 8.7 1 12.2 6.1 8.9 1.1 12.2 6.1 8.5 1 11.8 5.7 81 8 82 165 10.5 0 10.6 9.8 07/21/2006 09:20:00 7.7 1 10.3 5.3 8 1 10.7 5.3 7.6 1 9.5 4.9 81 9 77 165 10.5 0 10.6 9.8 07/21/2006 09:30:00 8.7 1.3 11.5 4.9 9 1.4 11.8 5.3 8.5 1.3 11.5 5.3 80 9 84 165 10.5 0 10.9 9.8 07/21/2006 09:40:00 8.7 1.1 11.8 6.1 8.9 1.2 11.8 6.5 8.3 1.3 11.5 5.3 80 9 83 165 10.5 0 10.9 9.8 07/21/2006 09:50:00 8.4 1.2 11.5 5.3 8.6 1.3 11.5 5.7 8.1 1.2 11.8 5.3 81 8 82 165 10.5 0 10.9 9.8 07/21/2006 10:00:00 8.4 1.1 11.8 5.7 8.7 1.2 12.6 5.7 8.2 1 11.5 6.1 82 8 84 165 10.5 0 10.9 9.8 07/21/2006 10:10:00 8.9 1.1 11.5 5.7 9.2 1.1 12.2 6.1 8.7 1.1 11.1 6.1 86 7 97 165 10.5 0 10.9 9.8 07/21/2006 10:20:00 9.5 1.2 12.2 6.8 9.8 1.2 12.6 6.8 9.1 1.2 11.8 6.5 87 7 87 165 10.5 0 10.9 9.8 07/21/2006 10:30:00 9.6 1 11.5 6.5 9.9 1 11.8 6.5 9.3 1 11.5 6.5 87 6 99 165 10.5 0 11.1 10.6 07/21/2006 10:40:00 9 1.4 11.8 4.9 9.3 1.5 11.8 5.3 8.7 1.3 11.8 5.3 85 7 92 165 10.7 0 11.1 10.6 07/21/2006 10:50:00 9.7 1 11.8 7.2 10 1 12.2 7.2 9.3 1 11.8 6.8 84 7 87 165 10.7 0 10.9 10.6 07/21/2006 11:00:00 9.7 1 12.2 6.8 10 1 12.2 7.2 9.3 1.1 11.8 6.5 87 6 84 165 10.6 0 10.9 10.6 07/21/2006 11:10:00 10 1 11.8 7.2 10.3 1.1 12.2 7.6 9.5 1.1 11.8 7.2 89 6 88 165 10.7 0 10.9 10.6 07/21/2006 11:20:00 9.7 1 11.8 6.8 9.9 1 12.2 7.2 9.3 1.2 12.2 6.1 88 7 84 165 10.7 0 10.9 10.6 07/21/2006 11:30:00 9.7 1.3 12.6 5.7 9.9 1.3 13 6.1 9.2 1.2 12.2 6.1 90 6 92 165 10.7 0 10.9 10.6 07/21/2006 11:40:00 9.9 1 12.2 6.8 10.2 1 13 7.6 9.5 1.1 11.8 6.1 90 6 98 165 10.7 0 10.9 10.6 07/21/2006 11:50:00 9 1 11.8 6.5 9.3 1 11.8 6.5 8.6 1 11.1 5.7 86 6 87 165 10.7 0 10.9 10.6 07/21/2006 12:00:00 8.3 1 10.3 5.3 8.5 1 10.3 4.9 7.9 1 10.3 4.9 84 8 87 165 10.7 0.1 10.9 10.3 07/21/2006 12:10:00 9.8 1.1 12.2 7.2 10.1 1.1 12.6 7.2 9.4 1.1 12.2 6.5 89 7 89 165 10.7 0 10.9 10.3 07/21/2006 12:20:00 9.9 0.9 12.2 7.2 10.2 1 12.2 6.8 9.4 1 11.5 6.5 88 6 77 165 10.7 0 10.9 9.8 07/21/2006 12:30:00 9.2 1 11.8 6.1 9.5 1.1 11.8 5.7 8.9 1 11.1 6.1 89 7 96 165 10.7 0 10.9 10.6 07/21/2006 12:40:00 9.2 1.2 11.8 6.5 9.5 1.3 12.2 5.7 8.7 1.3 11.1 5.7 93 8 102 165 10.6 0 10.9 9.8 07/21/2006 12:50:00 9.4 1.1 11.5 6.1 9.6 1.1 11.8 6.1 8.9 1 11.5 6.5 93 6 91 165 10.7 0.1 10.9 10.1 07/21/2006 13:00:00 9.7 1.1 11.8 6.1 10 1.1 12.2 5.7 9.3 1 11.5 6.8 92 6 96 165 10.6 0 10.9 10.1 07/21/2006 13:10:00 9.6 1 11.8 6.5 9.9 1.1 11.8 6.8 9.1 1.1 11.8 6.1 93 6 102 165 10.5 0 10.9 10.1 07/21/2006 13:20:00 8.9 1 10.7 5.7 9.2 1 11.1 6.1 8.6 1 11.1 5.7 94 7 93 165 10.5 0 10.9 10.3 07/21/2006 13:30:00 9.2 1.2 11.8 6.1 9.4 1.2 12.2 6.1 8.6 1.2 11.8 6.1 92 7 94 165 10.5 0 10.9 10.1 07/21/2006 13:40:00 9.6 1 11.8 6.8 9.9 1 11.8 7.2 9 1 11.5 6.8 94 6 93 165 10.5 0 10.9 9.8 07/21/2006 13:50:00 8.6 0.9 10.7 5.3 8.8 1 11.1 5.3 8.3 1 11.1 4.6 89 6 90 165 10.5 0 10.9 10.1 07/21/2006 14:00:00 8.2 1 10.7 5.7 8.4 1.1 10.7 5.7 7.8 1 11.1 5.3 88 6 87 165 10.5 0 10.9 9.8 07/21/2006 14:10:00 9.1 1.1 11.1 6.1 9.4 1.2 11.5 5.7 8.7 1.1 11.1 6.1 86 7 87 165 10.5 0 10.9 9.8 07/21/2006 14:20:00 9.2 1.1 11.5 5.7 9.4 1.1 11.5 5.7 8.9 1.1 11.5 6.1 88 7 87 165 10.5 0 10.9 10.1 07/21/2006 14:30:00 9.2 1 11.5 5.7 9.4 1 11.8 6.1 8.8 1 11.8 6.5 86 7 84 165 10.6 0 10.9 10.1 07/21/2006 14:40:00 9.8 1 11.5 5.7 10.1 1.1 11.8 6.1 9.5 1 11.8 7.2 88 6 92 165 10.6 0.1 11.1 9.8 07/21/2006 14:50:00 8.9 1.1 11.8 5.7 9.1 1.2 11.8 6.1 8.4 1.2 11.5 5.3 85 8 102 165 10.6 0 10.9 10.1 07/21/2006 15:00:00 9.7 0.9 11.8 6.8 10 1 12.2 6.8 9.2 0.9 11.5 6.5 90 6 103 165 10.5 0 10.9 9.8 07/21/2006 15:10:00 9.1 1 10.7 5.7 9.4 1 11.1 6.1 8.7 1 10.7 6.1 90 6 94 165 10.5 0 10.9 9.8 07/21/2006 15:20:00 8.7 0.9 10.7 6.1 8.9 1 11.1 6.5 8.1 1 10.3 5.7 88 6 84 165 10.5 0 10.9 10.1 07/21/2006 15:30:00 8.9 0.8 10.7 6.5 9.2 0.8 10.7 6.5 8.3 0.9 10.7 5.3 88 6 89 165 10.5 0 10.9 9.8 07/21/2006 15:40:00 8.8 1 11.1 6.5 9 1 11.5 6.5 8.5 1 10.7 6.1 88 7 87 165 10.5 0 10.9 10.1 07/21/2006 15:50:00 8.9 1.1 11.5 6.1 9.2 1.1 11.8 6.5 8.6 1 11.1 6.5 86 6 90 165 10.5 0 10.9 10.1 07/21/2006 16:00:00 8.6 1 11.1 5.7 8.8 1.1 11.5 5.7 8.3 1 10.7 5.3 88 7 84 165 10.5 0 10.6 9.8 07/21/2006 16:10:00 9 1 11.1 6.5 9.3 1 11.5 6.1 8.5 1 10.7 6.1 90 7 87 165 10.5 0 10.6 10.1 07/21/2006 16:20:00 8.9 1 11.1 5.7 9.1 1.1 11.8 6.1 8.4 1.1 11.1 4.9 91 8 88 165 10.5 0 10.6 9.8 07/21/2006 16:30:00 9.3 1 11.1 6.8 9.6 1 11.5 6.5 8.6 1 10.7 5.3 93 7 75 165 10.5 0 10.6 10.1 07/21/2006 16:40:00 9.3 0.9 11.1 6.5 9.5 1 11.5 5.7 8.9 0.9 11.5 6.1 93 6 102 165 10.4 0 10.6 9.8 07/21/2006 16:50:00 8.8 0.8 10.3 5.7 9 0.8 10.7 6.1 8.3 0.9 9.9 5.7 92 6 88 165 10.4 0 10.6 9.8 07/21/2006 17:00:00 9.2 1 11.1 6.5 9.5 1.1 11.5 6.5 8.8 1.1 11.1 6.1 90 6 89 165 10.4 0 10.6 9.8 07/21/2006 17:10:00 9 0.8 10.7 6.8 9.2 0.9 11.1 6.5 8.5 0.9 10.3 5.7 93 6 97 165 10.3 0 10.6 9.8 07/21/2006 17:20:00 8.2 0.9 9.9 6.1 8.4 1 10.3 6.1 7.8 1 10.3 5.3 91 6 88 165 10.3 0 10.6 9.8 07/21/2006 17:30:00 8 1 9.9 5.7 8.2 1 10.3 5.3 7.5 0.9 9.5 4.9 90 6 87 165 10.3 0 10.6 9.8 07/21/2006 17:40:00 8.6 0.8 10.3 6.5 8.8 0.9 10.7 6.1 8.1 0.9 10.3 5.7 95 5 97 165 10.2 0 10.6 9.8 07/21/2006 17:50:00 7 0.8 8.8 4.9 7.1 0.8 9.1 5.7 6.8 0.8 8.8 4.9 83 7 86 165 10.3 0 10.9 9.8 07/21/2006 18:00:00 7.5 1 10.3 4.9 7.7 1.1 10.3 5.3 7.3 1 9.5 5.3 83 7 90 165 10.2 0.1 10.6 9.8 07/21/2006 18:10:00 8 0.8 9.5 5.3 8.2 0.9 9.5 5.7 7.7 0.9 9.5 5.3 88 6 91 165 10.2 0 10.3 9.8 07/21/2006 18:20:00 7.4 0.8 9.5 4.9 7.6 0.9 9.5 4.9 7.1 0.9 9.5 4.9 83 7 83 165 10.3 0 10.6 10.1 07/21/2006 18:30:00 7.8 0.9 9.9 5.3 8 1 10.3 5.7 7.4 0.9 9.5 5.3 82 7 77 165 10.3 0 10.6 10.1 07/21/2006 18:40:00 8.9 1 11.5 6.1 9.2 1 11.5 6.5 8.5 1.1 11.5 5.7 87 7 79 165 10.4 0 10.6 10.1 07/21/2006 18:50:00 8.3 1 10.7 5.7 8.5 1.1 10.7 5.7 8.1 1 10.7 6.1 84 7 84 165 10.3 0 10.6 10.1 07/21/2006 19:00:00 8.6 1 11.1 6.1 8.8 1 11.5 6.1 8.1 1 9.9 5.7 87 7 85 165 10.3 0 10.6 10.1 07/21/2006 19:10:00 8.7 1 10.7 6.1 8.9 1 11.1 6.1 8.2 1.1 11.1 5.7 89 7 96 165 10.3 0 10.6 10.1 07/21/2006 19:20:00 9 1 11.8 6.5 9.2 1 12.2 6.5 8.6 1.1 11.8 5.7 87 7 93 165 10.3 0 10.6 10.1 07/21/2006 19:30:00 9.8 1 11.8 6.5 10.1 1.1 12.2 6.5 9.5 1 11.8 6.5 90 6 88 165 10.1 0 10.3 9.8 07/21/2006 19:40:00 9.5 0.8 11.5 7.2 9.8 0.9 12.2 7.2 8.9 1 11.5 6.1 93 7 90 165 10.1 0 10.9 9.8 07/21/2006 19:50:00 10 0.8 11.8 7.2 10.3 0.9 12.2 8 9.4 1 12.2 6.8 101 5 105 165 10.1 0 10.3 9.6 07/21/2006 20:00:00 9 1 11.1 6.5 9.2 1 11.5 6.5 8.4 1 11.5 6.1 96 8 96 165 10 0 10.3 9.6 07/21/2006 20:10:00 9.6 1 11.5 5.7 9.8 1 11.8 5.3 9 1.1 11.5 5.7 99 6 97 165 10 0 10.3 9.6 07/21/2006 20:20:00 9 0.8 10.7 6.5 9.2 0.8 11.1 6.1 8.5 1 10.7 6.1 103 6 99 165 9.9 0 10.1 9.3 07/21/2006 20:30:00 8.9 0.8 10.7 6.1 9.1 0.9 11.1 6.1 8.3 1 11.5 5.7 97 6 95 165 9.9 0 10.1 9.3 07/21/2006 20:40:00 9.2 0.9 10.7 4.9 9.4 1 11.5 4.9 8.6 1 10.7 6.1 98 6 99 165 9.8 0 10.3 9.3 07/21/2006 20:50:00 9.2 0.8 11.1 7.2 9.4 0.8 11.1 7.2 8.5 0.9 10.7 6.5 101 6 97 165 9.9 0 10.1 9.6 07/21/2006 21:00:00 9.9 1 12.2 6.8 10.1 1 12.2 6.8 9.3 1.1 12.2 6.5 102 6 101 165 9.9 0 10.1 9.6 07/21/2006 21:10:00 9.9 1 11.8 6.5 10.1 1 12.2 6.8 9.3 1 11.8 5.7 103 6 107 165 9.9 0 10.1 9.6 07/21/2006 21:20:00 9.6 0.9 11.5 6.8 9.9 1 11.5 6.8 9.1 1 11.1 6.1 100 7 92 165 9.8 0 10.1 9.6 07/21/2006 21:30:00 9.7 0.7 11.5 7.2 9.9 0.7 11.8 7.6 8.9 1 11.1 6.1 100 6 98 165 9.8 0 10.3 9.3 07/21/2006 21:40:00 8.9 1 11.5 6.1 9 1 11.8 6.1 8.3 1 10.7 5.7 98 6 102 165 9.8 0 9.8 9.3 07/21/2006 21:50:00 8.3 0.8 10.3 6.1 8.4 0.9 10.7 5.7 7.8 0.9 9.9 5.3 94 6 104 165 9.8 0 9.8 9.6 07/21/2006 22:00:00 8.4 0.6 9.9 6.5 8.6 0.7 10.7 6.5 7.9 0.8 9.5 5.7 96 4 97 165 9.8 0 9.8 9.6 07/21/2006 22:10:00 8.6 0.7 10.7 6.5 8.8 0.8 10.7 6.5 8.1 0.8 10.3 5.7 97 6 106 165 9.7 0 9.8 9.3 07/21/2006 22:20:00 9.1 0.8 10.7 6.1 9.3 0.9 11.1 6.5 8.4 1 10.7 5.7 99 5 95 165 9.7 0 9.8 9.3 07/21/2006 22:30:00 8.7 0.8 10.3 6.1 8.9 0.8 10.3 6.1 8.1 0.9 10.3 5.7 100 4 98 165 9.7 0 9.8 9.3 07/21/2006 22:40:00 8.2 0.7 9.9 5.3 8.3 0.8 10.3 5.3 7.5 0.9 9.1 5.3 97 6 94 165 9.6 0 9.8 9.3 07/21/2006 22:50:00 8.1 0.6 9.1 6.1 8.3 0.6 9.5 6.1 7.5 0.7 9.1 5.3 96 5 92 165 9.8 0 9.8 9.6 07/21/2006 23:00:00 8 1.2 10.7 4.6 8.2 1.3 11.1 4.6 7.5 1.3 10.7 4.6 94 7 87 165 9.8 0 9.8 9.3 07/21/2006 23:10:00 9.5 0.8 11.1 5.7 9.8 0.9 11.5 5.7 8.9 1 11.1 5.7 99 5 101 165 9.8 0 9.8 9.3 07/21/2006 23:20:00 8.9 1.1 11.1 5.7 9.1 1.1 11.5 5.7 8.3 1.2 11.1 5.7 95 7 102 165 9.8 0.2 10.1 9 07/21/2006 23:30:00 9.3 0.9 11.5 6.5 9.5 0.9 11.8 6.1 8.7 1 11.5 5.3 101 6 98 165 9.8 0 9.8 9.3 07/21/2006 23:40:00 9.1 0.8 11.1 6.5 9.3 0.8 11.1 6.8 8.6 1 10.7 6.1 106 5 99 165 9.7 0 10.3 9.6 07/21/2006 23:50:00 9.2 0.7 11.5 6.8 9.4 0.7 11.8 6.8 8.7 0.8 11.1 6.1 107 4 105 165 9.7 0 9.8 9.6 07/22/2006 00:00:00 8.4 0.7 9.9 6.5 8.6 0.7 10.3 6.1 8 0.8 9.9 6.1 107 5 109 165 9.7 0 9.8 9.3 07/22/2006 00:10:00 8.7 0.8 10.3 6.1 8.9 0.8 10.7 6.1 8.1 1 10.3 5.7 102 5 105 165 9.7 0 9.8 9.6 07/22/2006 00:20:00 8.6 0.8 10.3 5.7 8.7 0.8 10.7 5.3 7.9 0.9 9.9 5.3 101 6 89 165 9.7 0 9.8 9.6 07/22/2006 00:30:00 9.1 0.6 10.3 6.1 9.3 0.7 10.7 6.5 8.5 0.8 10.7 6.1 102 4 96 165 9.7 0 9.8 9.6 07/22/2006 00:40:00 8.6 0.7 10.3 6.1 8.7 0.7 10.3 6.5 8.2 0.8 9.9 5.3 104 5 105 165 9.6 0 9.8 9.6 07/22/2006 00:50:00 8.3 0.6 9.5 5.7 8.4 0.7 10.3 5.7 7.6 0.8 9.5 5.3 102 5 106 165 9.6 0 9.8 9.6 07/22/2006 01:00:00 8 0.8 9.5 6.1 8.1 0.8 9.9 6.1 7.6 1 9.5 4.6 106 5 97 165 9.6 0 9.6 9.6 07/22/2006 01:10:00 7.6 0.6 9.1 5.3 7.7 0.7 9.1 4.9 7.2 0.7 9.1 5.3 111 5 105 165 9.6 0 10.1 9.3 07/22/2006 01:20:00 7.1 0.6 8.8 5.3 7.2 0.7 8.8 5.3 6.7 0.8 8.8 4.9 115 7 114 165 9.6 0 9.6 9.3 07/22/2006 01:30:00 7 0.5 8.8 5.7 7.2 0.5 8.8 5.7 6.8 0.6 8.4 4.9 110 5 118 165 9.6 0 9.6 9.3 07/22/2006 01:40:00 6.6 0.5 8 5.3 6.6 0.5 8 5.3 6.4 0.6 8.4 4.9 105 5 104 165 9.6 0 9.6 9.6 07/22/2006 01:50:00 6.9 0.5 8.4 5.3 7 0.5 8.8 5.7 6.5 0.7 8.4 4.9 103 5 103 165 9.6 0 9.6 9.6 07/22/2006 02:00:00 6.7 0.6 8 5.3 7 0.6 8.4 5.3 6.5 0.6 8.4 4.9 101 5 101 165 9.6 0 9.6 9.6 07/22/2006 02:10:00 7 0.6 8.4 5.3 7.2 0.6 8.8 5.3 6.5 0.7 8.4 4.6 100 5 95 165 9.6 0.1 10.3 9.3 07/22/2006 02:20:00 6.9 0.6 8.4 5.3 7 0.7 8.8 5.3 6.5 0.7 8 4.6 98 5 98 165 9.6 0.1 9.6 9 07/22/2006 02:30:00 6.3 0.6 7.2 4.6 6.4 0.6 7.6 4.6 6.1 0.6 7.2 4.6 96 4 96 165 9.6 0.2 9.8 9 07/22/2006 02:40:00 5.7 0.5 6.8 4.2 5.8 0.5 6.8 4.6 5.5 0.5 6.8 3.8 91 5 99 165 9.5 0.2 9.8 9 07/22/2006 02:50:00 4.8 0.7 6.5 2.6 4.9 0.8 6.8 2.6 4.7 0.6 6.1 3.4 84 6 88 165 9.5 0.2 9.8 9 07/22/2006 03:00:00 4.6 0.8 6.8 2.6 4.7 0.9 6.8 2.6 4.5 0.8 6.5 2.6 78 9 85 165 9.6 0.1 9.8 9 07/22/2006 03:10:00 6 0.9 7.6 3.8 6.2 0.9 8 3.8 5.9 0.8 7.6 4.2 89 8 98 165 9.6 0.2 9.8 9 07/22/2006 03:20:00 6.3 0.6 7.6 4.9 6.5 0.6 8 4.9 6 0.6 8 4.2 96 7 82 165 9.4 0.1 9.6 9 07/22/2006 03:30:00 6.7 0.6 8 4.9 6.9 0.6 8 4.9 6.3 0.7 8.4 4.2 96 5 92 165 9.4 0.2 9.6 9 07/22/2006 03:40:00 6.4 0.6 7.6 4.2 6.5 0.6 7.6 4.2 6 0.7 7.2 3.8 90 6 92 165 9.4 0.1 9.6 9 07/22/2006 03:50:00 6.7 0.8 8.4 4.6 6.9 0.8 8.8 4.6 6.4 0.8 8.4 3.8 89 7 89 165 9.4 0.2 9.6 9 07/22/2006 04:00:00 7 0.8 8.8 4.9 7.1 0.8 9.1 5.3 6.5 0.8 8.4 4.2 92 7 94 165 9.5 0.2 10.1 9 07/22/2006 04:10:00 7.3 0.8 9.5 4.6 7.5 0.8 9.9 5.3 6.9 0.8 8.4 4.9 92 6 91 165 9.4 0.2 9.6 9 07/22/2006 04:20:00 8.3 0.8 10.3 5.3 8.5 0.8 10.3 5.3 7.8 0.9 9.5 4.9 99 6 95 165 9.5 0.2 9.6 9 07/22/2006 04:30:00 7.6 0.8 9.5 5.3 7.8 0.8 9.5 5.7 7.1 0.9 8.8 4.6 101 6 104 165 9.4 0.2 9.6 9 07/22/2006 04:40:00 7 0.6 8.8 5.3 7.2 0.6 8.8 5.3 6.9 0.7 8.4 4.9 109 6 112 165 9.5 0 9.6 9 07/22/2006 04:50:00 6.4 0.4 7.2 5.3 6.5 0.4 7.6 5.3 6.2 0.5 7.2 3.8 113 4 115 165 9.5 0 9.6 9.3 07/22/2006 05:00:00 5.8 0.5 6.8 3.8 6 0.5 7.2 3.8 5.7 0.6 7.2 4.2 111 4 116 165 9.6 0 9.6 9.6 07/22/2006 05:10:00 5.6 0.4 6.8 4.2 5.7 0.4 6.8 4.6 5.4 0.5 6.5 3.8 106 5 118 165 9.6 0.1 9.6 9.3 07/22/2006 05:20:00 6.4 0.6 8.4 4.9 6.6 0.6 8.4 4.9 6 0.7 8 4.2 111 5 111 165 9.4 0 9.6 9 07/22/2006 05:30:00 6.5 0.5 7.6 4.6 6.7 0.5 8 4.9 6.3 0.6 8 4.2 113 5 121 165 9.3 0 9.6 9 07/22/2006 05:40:00 6.4 0.4 7.6 4.9 6.5 0.4 7.6 5.3 6.1 0.6 7.6 3.8 109 4 110 165 9.2 0 9.3 9 07/22/2006 05:50:00 6.7 0.5 8 5.3 6.9 0.5 8 5.3 6.5 0.6 7.6 4.6 108 5 116 165 9.2 0 9.3 9 07/22/2006 06:00:00 6.4 0.5 7.2 4.9 6.5 0.5 7.6 5.3 6.1 0.6 7.2 4.6 106 3 110 165 9 0 9.3 8.8 07/22/2006 06:10:00 5.6 0.7 7.2 3.4 5.7 0.7 7.2 3.8 5.3 0.8 6.5 3 103 5 105 165 9 0 9.3 8.8 07/22/2006 06:20:00 5.3 0.7 7.2 3 5.5 0.7 7.2 3.4 5 0.8 6.8 3 95 8 91 165 9 0 9.3 8.8 07/22/2006 06:30:00 5.8 1 8 3.8 6.1 1 8 3.8 5.6 1 8 3 84 7 78 165 9.3 0 9.3 8.8 07/22/2006 06:40:00 6.6 0.6 7.6 4.9 6.8 0.6 8 4.9 6.3 0.6 8 4.6 89 6 87 165 9.4 0 9.6 8.8 07/22/2006 06:50:00 6.5 1 8.8 4.2 6.7 1 8.8 4.2 6.3 0.9 8.8 4.2 89 8 86 165 9.4 0 9.8 8.8 07/22/2006 07:00:00 6.9 0.6 8.4 4.9 7.1 0.6 8.4 4.9 6.6 0.8 8.4 4.6 89 8 94 165 9.2 0 9.3 8.8 07/22/2006 07:10:00 6.9 0.7 8.4 4.6 7.1 0.7 8.8 4.9 6.5 0.7 8.4 4.2 94 6 94 165 9.2 0.1 9.3 8.8 07/22/2006 07:20:00 6.5 0.8 8 3.8 6.7 0.8 8 4.2 6.1 0.8 8 4.2 96 6 100 165 9.2 0 9.3 8.8 07/22/2006 07:30:00 5.9 0.7 8.4 3.8 6.1 0.7 8 3.8 5.7 0.6 7.2 4.2 92 6 83 165 9.2 0 9.3 8.8 07/22/2006 07:40:00 5.9 0.8 7.6 3.8 6.1 0.8 7.6 3.8 5.7 0.8 7.6 3.8 89 7 94 165 9.2 0 9.3 8.8 07/22/2006 07:50:00 5.5 0.6 6.8 3 5.7 0.6 6.8 3.4 5.3 0.7 6.8 3.4 89 6 83 165 9.1 0 9.3 8.8 07/22/2006 08:00:00 6 0.6 7.2 4.6 6.2 0.6 7.6 4.6 5.8 0.6 7.6 4.2 92 6 94 165 9.2 0.1 9.3 8.8 07/22/2006 08:10:00 6.2 0.6 7.2 4.6 6.4 0.7 7.6 4.2 5.9 0.7 7.6 3.8 90 6 91 165 9 0.1 9.3 8.8 07/22/2006 08:20:00 5.6 0.7 7.2 3.4 5.8 0.7 7.6 3.8 5.5 0.6 7.2 3.8 84 7 81 165 9 0.1 9.3 8.5 07/22/2006 08:30:00 5.8 0.7 7.2 4.2 6 0.7 7.6 4.2 5.6 0.7 7.2 4.2 84 6 87 165 9.2 0.1 9.3 8.8 07/22/2006 08:40:00 5.3 0.7 7.2 3 5.5 0.8 6.8 3 5.3 0.7 7.2 3.4 82 6 81 165 9.2 0.1 9.6 8.8 07/22/2006 08:50:00 5.3 0.8 6.8 3 5.4 0.8 7.2 2.6 5 0.9 7.2 3 81 6 88 165 9.3 0.1 9.8 9 07/22/2006 09:00:00 5.2 0.9 7.6 3.4 5.3 1 7.6 3.4 4.9 0.9 7.2 3.4 78 9 83 165 9.3 0.1 9.6 8.8 07/22/2006 09:10:00 5.9 0.8 8 3.8 6.1 0.8 8.4 4.2 5.8 0.8 8 3.8 80 8 81 165 9.4 0.2 9.6 8.8 07/22/2006 09:20:00 6.5 0.8 8 4.2 6.7 0.8 8.4 4.2 6.3 0.9 8 3.8 81 6 76 165 9.5 0.2 9.8 9 07/22/2006 09:30:00 6.3 0.9 8.4 3.8 6.5 0.9 8.8 3.8 6.1 0.9 8.4 3.4 80 8 68 165 9.6 0 9.8 9 07/22/2006 09:40:00 5.7 0.9 7.6 3.4 5.8 0.9 8 3.4 5.5 1 8 3 78 9 78 165 9.6 0 9.8 9.3 07/22/2006 09:50:00 5.5 0.8 7.6 3.8 5.6 0.9 7.6 3.8 5.5 0.7 7.2 3.8 79 8 83 165 9.7 0 9.8 9.6 07/22/2006 10:00:00 5.7 0.9 7.6 3.4 5.9 0.9 7.6 3 5.4 0.8 7.2 3.4 80 8 97 165 9.6 0.1 10.1 9.3 07/22/2006 10:10:00 7.2 0.9 8.8 4.9 7.3 1 9.1 4.6 6.9 0.8 8.8 4.9 83 7 87 165 9.6 0.1 9.8 9.3 07/22/2006 10:20:00 7.2 0.8 8.4 4.9 7.4 0.8 8.8 4.9 6.8 0.9 8.4 4.6 85 6 88 165 9.5 0.1 9.8 9 07/22/2006 10:30:00 6.9 0.6 8.4 4.9 7 0.7 8.4 4.9 6.6 0.7 8.4 4.6 87 5 94 165 9.5 0.1 9.8 9.3 07/22/2006 10:40:00 6.9 0.7 8.4 4.6 7 0.7 8.8 4.2 6.4 0.8 8 4.2 92 6 106 165 9.6 0.1 10.3 9.3 07/22/2006 10:50:00 6.3 0.5 7.6 4.6 6.5 0.5 7.6 4.6 5.9 0.7 7.2 4.2 97 6 101 165 9.7 0 10.3 9.3 07/22/2006 11:00:00 5.6 0.7 6.8 3.4 5.8 0.6 7.2 3.4 5.4 0.8 6.8 3.4 96 5 100 165 9.8 0 10.1 9.6 07/22/2006 11:10:00 5.5 0.5 6.5 4.2 5.6 0.5 6.5 4.2 5.2 0.5 6.5 3.8 98 6 95 165 9.8 0 10.1 9.6 07/22/2006 11:20:00 5.2 0.5 6.8 3.8 5.3 0.5 6.5 3.8 5 0.6 6.1 3.4 107 5 112 165 10 0 10.3 9.8 07/22/2006 11:30:00 4.5 0.4 5.3 3.4 4.6 0.4 5.7 3.4 4.4 0.4 5.3 2.6 109 5 112 165 10.2 0 10.6 10.1 07/22/2006 11:40:00 4.4 0.4 5.3 3 4.6 0.4 5.7 3 4.3 0.5 5.3 3 109 5 111 165 10.2 0 10.6 10.1 07/22/2006 11:50:00 4.8 0.7 6.5 3 4.9 0.7 6.8 3 4.7 0.7 6.5 3 116 7 116 165 10.1 0 10.3 9.8 07/22/2006 12:00:00 5.3 0.6 6.8 4.2 5.4 0.6 7.2 3.8 5.2 0.6 6.8 3.8 125 6 122 165 9.8 0 10.1 9.6 07/22/2006 12:10:00 5 0.6 6.5 3.8 5.1 0.6 6.8 3.8 5 0.7 6.8 3.4 123 6 116 165 10 0 10.3 9.6 07/22/2006 12:20:00 4.4 0.6 6.1 2.6 4.5 0.6 6.1 3 4.4 0.6 5.7 2.6 119 7 121 165 10 0 10.1 9.6 07/22/2006 12:30:00 5 0.5 6.5 3.4 5.1 0.6 6.8 3.8 4.9 0.6 6.5 3 116 9 110 165 9.9 0 10.3 9.6 07/22/2006 12:40:00 4.2 0.7 5.7 2.3 4.4 0.7 6.1 2.6 4.2 0.6 5.3 2.3 103 7 103 165 10.1 0 10.3 10.1 07/22/2006 12:50:00 4.1 0.5 5.3 2.6 4.3 0.5 5.3 2.6 4.1 0.6 4.9 2.3 103 6 102 165 10.1 0 10.3 9.8 07/22/2006 13:00:00 4 0.5 4.9 2.3 4.1 0.5 5.3 2.6 3.9 0.6 4.9 2.3 103 6 105 165 10.1 0 10.3 10.1 07/22/2006 13:10:00 4.4 0.5 5.7 3 4.5 0.6 6.1 3 4.2 0.7 5.7 2.3 112 6 115 165 10.1 0 10.6 9.8 07/22/2006 13:20:00 4.5 0.6 5.7 2.6 4.7 0.6 6.1 3 4.5 0.6 5.7 2.3 114 9 121 165 10.1 0 10.3 10.1 07/22/2006 13:30:00 4.5 0.6 6.1 2.6 4.6 0.6 6.5 2.6 4.4 0.6 6.1 2.6 115 8 108 165 10.1 0 10.3 9.8 07/22/2006 13:40:00 4.9 0.5 6.1 3.4 5.1 0.5 6.1 3.4 4.9 0.6 6.1 3.4 120 6 119 165 10.1 0 10.6 9.8 07/22/2006 13:50:00 3.9 0.6 5.3 2.3 4 0.6 5.7 2.3 3.9 0.6 5.3 2.3 121 11 112 165 10.3 0 10.9 10.3 07/22/2006 14:00:00 4.3 0.6 5.7 2.6 4.4 0.6 6.1 2.6 4.3 0.6 6.1 2.6 109 6 99 165 10.2 0 10.6 10.3 07/22/2006 14:10:00 4.2 0.6 5.3 2.6 4.3 0.6 5.7 2.6 4.1 0.5 5.7 2.6 106 7 114 165 10.6 0.1 10.9 10.3 07/22/2006 14:20:00 4.2 0.7 6.1 3 4.3 0.7 6.1 2.6 4.1 0.7 5.7 2.3 100 7 99 165 10.3 0.2 10.9 10.3 07/22/2006 14:30:00 5 0.7 6.1 2.6 5.1 0.7 6.5 2.3 4.8 0.7 6.5 3 110 7 95 165 10.4 0 10.9 10.3 07/22/2006 14:40:00 4.5 0.6 6.1 3 4.6 0.6 6.1 3 4.5 0.6 6.1 3 114 6 121 165 10.7 0 10.9 10.6 07/22/2006 14:50:00 4.5 0.5 5.7 3 4.6 0.5 6.1 3 4.4 0.6 6.1 3 109 8 106 165 10.5 0 10.9 10.6 07/22/2006 15:00:00 4.4 0.7 6.8 3 4.6 0.7 6.8 2.6 4.3 0.7 6.5 2.3 104 7 105 165 10.5 0 10.9 9.8 07/22/2006 15:10:00 4.7 0.6 6.1 3 4.8 0.6 6.1 3 4.6 0.6 6.1 3 103 6 94 165 10.4 0 10.6 9.8 07/22/2006 15:20:00 4.5 0.5 5.3 2.6 4.6 0.5 5.7 3 4.3 0.6 6.1 2.6 104 8 100 165 10.4 0 10.6 9.8 07/22/2006 15:30:00 4.4 0.7 6.5 2.6 4.5 0.7 6.8 2.6 4.3 0.7 6.1 2.6 104 7 108 165 10.4 0 10.9 10.3 07/22/2006 15:40:00 4.2 0.8 5.7 2.3 4.3 0.8 6.1 1.9 4.1 0.8 6.1 2.3 103 8 108 165 10.5 0 10.9 10.3 07/22/2006 15:50:00 4.1 0.6 6.1 2.3 4.2 0.7 5.7 2.6 4 0.7 5.7 2.3 102 7 104 165 10.7 0.2 11.4 10.3 07/22/2006 16:00:00 4.1 0.6 5.7 2.6 4.2 0.6 5.7 2.6 4 0.6 5.3 2.6 103 8 107 165 10.7 0.2 11.4 9.8 07/22/2006 16:10:00 4.6 0.6 5.7 2.3 4.7 0.6 6.1 2.6 4.6 0.6 5.7 3 115 8 107 165 10.3 0.1 10.6 10.3 07/22/2006 16:20:00 5.4 0.6 7.2 3.8 5.5 0.6 6.8 3 5.2 0.6 7.2 3.4 121 7 121 165 10.2 0 10.6 10.1 07/22/2006 16:30:00 6.3 0.6 7.6 4.6 6.3 0.6 7.6 4.6 6.3 0.6 7.6 4.9 129 7 124 165 10 0 10.3 9.6 07/22/2006 16:40:00 6.4 0.6 7.6 4.9 6.5 0.6 8 4.9 6.3 0.6 8 4.6 128 5 133 165 9.9 0 10.1 9.6 07/22/2006 16:50:00 5.8 0.8 7.6 3.8 5.9 0.8 7.6 4.2 5.8 0.8 8 3.8 125 5 116 165 10 0 10.3 9.6 07/22/2006 17:00:00 5.4 0.8 6.8 3.4 5.5 0.8 7.2 3.8 5.3 0.8 7.2 3.4 121 8 135 165 10 0 10.3 9.8 07/22/2006 17:10:00 5 0.5 6.5 3.8 5.2 0.5 6.5 3.8 4.9 0.5 6.1 3.8 122 6 126 165 10 0 10.3 9.8 07/22/2006 17:20:00 5.2 0.6 6.8 3.8 5.4 0.6 7.2 3.8 5.2 0.6 6.8 3.4 126 6 130 165 10 0 10.3 9.8 07/22/2006 17:30:00 5.7 0.5 7.2 4.2 5.9 0.5 7.2 4.2 5.6 0.6 7.2 4.2 122 6 118 165 10 0 10.3 9.8 07/22/2006 17:40:00 5.6 0.5 6.8 3.8 5.7 0.5 6.8 4.2 5.5 0.6 7.2 4.2 123 5 124 165 10.1 0 10.6 9.6 07/22/2006 17:50:00 5.2 0.6 6.5 3.8 5.3 0.6 6.5 3.8 5.1 0.6 6.8 3.4 127 7 127 165 10.1 0 10.3 9.8 07/22/2006 18:00:00 4.8 0.6 6.5 3.4 4.9 0.6 6.5 3.4 4.7 0.6 6.5 3.4 117 8 113 165 10 0 10.3 9.8 07/22/2006 18:10:00 4.3 0.6 6.1 3 4.4 0.6 6.1 3 4.3 0.7 5.7 3 116 6 108 165 10 0 10.3 9.8 07/22/2006 18:20:00 4.1 0.6 5.7 2.6 4.2 0.7 6.1 2.6 3.9 0.7 5.3 2.6 107 7 110 165 10 0 10.3 9.8 07/22/2006 18:30:00 4.2 0.5 5.3 3 4.3 0.5 5.3 3 4 0.5 4.9 2.6 107 6 110 165 10.1 0 10.3 9.6 07/22/2006 18:40:00 3.5 0.4 4.6 2.3 3.6 0.5 4.6 2.3 3.4 0.5 4.6 2.3 107 8 106 165 10.1 0 10.3 9.8 07/22/2006 18:50:00 3.6 0.4 4.6 2.3 3.7 0.4 4.6 2.6 3.4 0.5 4.6 2.3 105 6 99 165 10.1 0 10.3 9.8 07/22/2006 19:00:00 3.4 0.4 4.6 2.3 3.5 0.4 4.9 2.3 3.4 0.5 4.6 1.9 108 5 113 165 10.1 0 10.3 9.8 07/22/2006 19:10:00 3.5 0.4 4.6 2.6 3.6 0.4 4.9 2.6 3.4 0.4 4.6 2.3 105 5 97 165 10 0 10.1 9.8 07/22/2006 19:20:00 3.5 0.4 4.6 2.3 3.6 0.4 4.9 2.3 3.4 0.4 4.9 1.9 109 5 114 165 10 0 10.1 9.8 07/22/2006 19:30:00 3.7 0.6 4.9 1.9 3.7 0.6 5.3 2.3 3.6 0.6 5.3 2.6 117 8 105 165 10 0 10.1 9.6 07/22/2006 19:40:00 4.4 0.7 6.5 3 4.4 0.7 6.5 3 4.2 0.7 6.1 2.6 120 8 118 165 10 0 10.3 9.8 07/22/2006 19:50:00 5 0.6 6.5 3 5.1 0.6 6.8 3.4 4.8 0.6 6.5 3 120 6 119 165 10 0 10.3 9.8 07/22/2006 20:00:00 5 0.6 6.5 3.4 5.1 0.6 6.5 3.4 4.9 0.6 6.5 3 123 7 117 165 10 0 10.1 9.8 07/22/2006 20:10:00 5.3 0.6 6.8 3.4 5.4 0.6 7.2 3.4 5.3 0.6 6.8 3.8 124 5 112 165 9.9 0 10.3 9.8 07/22/2006 20:20:00 5.8 0.6 7.2 4.6 5.8 0.6 7.6 4.2 5.7 0.6 7.6 3.8 129 7 129 165 9.8 0 9.8 9.6 07/22/2006 20:30:00 5.5 0.7 7.2 3.4 5.6 0.7 7.2 3.8 5.4 0.7 6.8 3.8 127 6 128 165 9.8 0 9.8 9.6 07/22/2006 20:40:00 5 0.6 7.2 3.4 5.1 0.6 7.2 3 4.8 0.6 6.8 3 128 6 126 165 9.8 0 10.1 9.6 07/22/2006 20:50:00 5.1 0.5 6.5 3.4 5.2 0.5 6.5 3.8 5.1 0.5 6.1 3.4 128 7 135 165 9.8 0 9.8 9.6 07/22/2006 21:00:00 4.9 0.5 6.1 3.8 5 0.5 6.5 3.8 4.8 0.6 6.5 3.4 127 6 126 165 9.8 0 9.8 9.6 07/22/2006 21:10:00 4.9 0.5 6.5 3.4 5 0.5 6.5 3.8 4.8 0.6 6.5 2.6 126 5 130 165 9.7 0 9.8 9.6 07/22/2006 21:20:00 4.8 0.5 6.5 3.4 5 0.5 6.8 3.8 4.7 0.6 6.5 3 126 6 138 165 9.7 0 9.8 9.6 07/22/2006 21:30:00 4.8 0.6 6.5 3.4 4.9 0.6 6.8 3.4 4.7 0.6 6.5 3 125 8 126 165 9.7 0 9.8 9.6 07/22/2006 21:40:00 5 0.6 6.5 3.4 5.1 0.6 6.5 3.8 4.9 0.6 6.5 3.4 131 7 130 165 9.7 0 10.1 9.6 07/22/2006 21:50:00 4.8 0.6 6.5 3 4.9 0.6 6.5 3.4 4.6 0.7 6.1 2.6 133 9 135 165 9.7 0 9.8 9.6 07/22/2006 22:00:00 4.7 0.5 6.5 3 4.8 0.5 6.1 3.4 4.5 0.5 6.1 3 132 6 134 165 9.7 0 9.8 9.6 07/22/2006 22:10:00 4.9 0.5 6.5 3.8 5 0.5 6.5 3.4 4.8 0.5 6.1 3.4 134 7 135 165 9.7 0 9.8 9.6 07/22/2006 22:20:00 5.1 0.5 6.5 3.8 5.2 0.5 6.5 4.2 4.9 0.6 6.5 3.4 135 8 135 165 9.7 0 9.8 9.6 07/22/2006 22:30:00 5.6 0.8 7.6 3 5.7 0.8 7.6 3 5.5 0.8 7.6 3 135 7 134 165 9.7 0 10.1 9.6 07/22/2006 22:40:00 6.7 0.6 8.4 4.9 6.7 0.6 8.4 5.3 6.6 0.7 8.4 4.2 136 5 130 165 9.6 0 9.8 9.6 07/22/2006 22:50:00 6.7 0.6 8.4 4.6 6.7 0.6 8.4 4.9 6.4 0.6 8 4.9 136 6 130 165 9.7 0 9.8 9.6 07/22/2006 23:00:00 6.2 0.6 7.6 4.2 6.2 0.6 7.6 4.6 6 0.6 7.6 4.2 140 6 135 165 9.7 0 9.8 9.6 07/22/2006 23:10:00 6.4 0.8 8.4 4.6 6.4 0.8 8.4 4.6 6.3 0.8 8.4 4.6 140 6 142 165 9.7 0 9.8 9.6 07/22/2006 23:20:00 6.9 0.6 9.1 5.3 6.9 0.6 9.1 4.9 6.6 0.7 8.4 4.9 135 5 128 165 9.7 0 9.8 9.6 07/22/2006 23:30:00 7 0.7 8.8 4.9 7 0.6 8.4 4.9 6.7 0.7 8.8 4.6 137 6 144 165 9.6 0 9.8 9.6 07/22/2006 23:40:00 6.9 0.8 8.8 4.6 6.9 0.8 9.1 4.9 6.7 0.9 8.8 3.8 137 6 143 165 9.6 0 9.8 9.6 07/22/2006 23:50:00 7.2 0.6 9.1 5.3 7.2 0.6 8.8 5.3 6.9 0.8 8.4 4.6 137 6 121 165 9.6 0 9.8 9.6 07/23/2006 00:00:00 6.9 0.6 8.4 5.3 7 0.6 8.8 5.3 6.8 0.6 8 5.3 138 5 144 165 9.6 0 9.8 9.6 07/23/2006 00:10:00 7.4 0.7 9.1 5.3 7.4 0.7 9.1 5.3 6.9 0.8 8.8 4.2 134 6 143 165 9.6 0 9.8 9.6 07/23/2006 00:20:00 7.9 0.7 9.5 5.7 7.9 0.7 9.5 5.7 7.8 0.7 10.3 6.1 136 6 145 165 9.6 0 9.8 9.6 07/23/2006 00:30:00 7.4 0.6 8.8 5.7 7.4 0.6 8.8 5.7 7.2 0.8 8.8 5.3 137 6 132 165 9.6 0 9.8 9.6 07/23/2006 00:40:00 7.9 0.8 9.5 5.7 7.9 0.8 9.5 6.1 7.6 0.8 9.5 6.1 136 5 129 165 9.6 0 9.8 9.6 07/23/2006 00:50:00 7.7 0.7 9.1 5.3 7.7 0.7 9.5 5.7 7.5 0.9 9.1 4.6 135 7 138 165 9.6 0 9.8 9.6 07/23/2006 01:00:00 8.3 0.7 9.9 6.1 8.3 0.7 10.3 6.5 8.1 0.9 10.3 6.1 131 6 130 165 9.6 0 9.8 9.6 07/23/2006 01:10:00 8.4 0.7 10.7 6.1 8.5 0.7 10.3 6.1 8.2 0.8 10.7 6.1 134 6 121 165 9.6 0 9.8 9 07/23/2006 01:20:00 7.9 0.8 9.5 6.1 7.9 0.8 9.5 6.1 7.6 0.9 9.1 4.9 135 6 139 165 9.6 0 9.8 9 07/23/2006 01:30:00 8.2 0.6 9.5 6.5 8.2 0.6 9.9 6.1 8 0.7 9.5 5.3 137 5 140 165 9.6 0.1 9.8 9 07/23/2006 01:40:00 8.5 0.6 9.9 6.8 8.5 0.6 9.9 6.8 8.5 0.7 9.9 6.1 138 5 133 165 9.6 0.1 9.6 9 07/23/2006 01:50:00 8.3 0.8 9.9 6.1 8.3 0.8 9.9 6.5 8.1 0.9 9.9 5.7 137 5 135 165 9.6 0 9.6 9 07/23/2006 02:00:00 8 0.6 9.1 6.1 8 0.6 9.1 6.5 7.8 0.7 9.5 5.3 136 5 132 165 9.6 0 9.6 9.3 07/23/2006 02:10:00 7.5 0.7 9.1 5.7 7.6 0.7 9.1 5.3 7.3 0.7 9.1 5.3 135 5 133 165 9.5 0 9.6 9.3 07/23/2006 02:20:00 7.1 0.8 9.5 4.9 7.1 0.8 9.1 4.9 7.1 0.9 9.1 4.6 138 6 143 165 9.4 0 9.6 9.3 07/23/2006 02:30:00 7.4 0.7 9.1 5.7 7.4 0.7 9.1 5.7 7.1 0.7 8.8 4.9 137 6 135 165 9.4 0 9.6 9 07/23/2006 02:40:00 7.3 0.6 8.8 5.7 7.4 0.6 8.8 6.1 7.2 0.6 8.8 5.7 136 5 143 165 9.4 0 9.6 9 07/23/2006 02:50:00 8.5 1 10.3 6.5 8.5 1 10.7 6.5 8.5 1 10.7 6.1 140 6 136 165 9.4 0 9.6 9.3 07/23/2006 03:00:00 9.6 0.8 11.5 7.2 9.6 0.8 11.5 7.2 9.5 0.9 11.8 6.1 138 5 137 165 9.4 0 9.6 9.3 07/23/2006 03:10:00 9.9 0.9 11.8 7.6 10 0.9 11.8 8 9.7 1 11.8 6.8 137 6 140 165 9.3 0 9.3 9 07/23/2006 03:20:00 10.2 1 12.6 7.6 10.3 1 12.6 7.6 10.1 1 12.6 6.8 141 6 147 165 9.2 0 9.3 9 07/23/2006 03:30:00 9.3 0.8 11.5 6.8 9.4 0.8 11.5 6.8 9 0.8 11.1 6.5 138 7 138 165 9.1 0 9.3 9 07/23/2006 03:40:00 8.1 1 10.7 5.3 8.2 1 10.7 5.3 7.9 1 10.3 5.3 134 9 142 165 9.1 0 9.3 9 07/23/2006 03:50:00 8.2 0.7 9.9 6.5 8.2 0.7 9.9 6.5 8.1 0.8 10.7 6.5 131 8 122 165 9.1 0 9.3 9 07/23/2006 04:00:00 8 0.8 9.9 5.3 8.1 0.9 9.9 4.9 7.7 0.9 9.9 4.9 125 7 129 165 9.1 0 9.3 9 07/23/2006 04:10:00 8 0.7 9.5 6.1 8.2 0.7 9.9 6.5 7.8 0.8 9.5 5.7 121 6 121 165 9 0 9 8.8 07/23/2006 04:20:00 8.9 1.1 12.6 5.7 9.1 1.1 12.6 6.1 8.5 1.1 11.5 5.7 119 5 114 165 9.1 0 9.3 9 07/23/2006 04:30:00 9 0.9 11.1 6.5 9.2 0.9 11.5 6.8 8.9 1 11.8 6.5 125 6 123 165 9.2 0 9.3 9 07/23/2006 04:40:00 10.3 1 13 7.6 10.3 1 13 8 10.2 1 12.6 7.6 131 6 124 165 9.1 0 9.3 9 07/23/2006 04:50:00 9.3 0.8 11.1 6.8 9.4 0.8 11.5 7.2 9.2 0.9 11.5 6.5 130 6 137 165 9 0 9 9 07/23/2006 05:00:00 8.8 0.6 10.7 6.8 9 0.6 11.5 7.2 8.7 0.7 10.3 6.8 125 5 116 165 8.9 0 9 8.5 07/23/2006 05:10:00 8.9 1 11.5 6.1 9.1 1 11.5 6.1 8.8 1.1 11.8 6.1 127 7 122 165 8.9 0 9 8.5 07/23/2006 05:20:00 8.9 0.9 11.5 5.7 9 0.9 11.1 5.7 8.6 1.2 11.1 5.7 129 6 129 165 8.9 0 9 8.8 07/23/2006 05:30:00 8.8 0.7 10.7 6.5 8.9 0.7 10.7 6.8 8.5 0.8 10.3 5.3 123 5 122 165 9 0 9 8.8 07/23/2006 05:40:00 10.2 1 13 7.2 10.3 1 13.3 7.2 9.8 1 12.2 6.5 117 6 116 165 9 0 9.3 9 07/23/2006 05:50:00 9.9 1.1 12.6 7.6 10.1 1.1 12.6 7.6 9.7 1.1 12.2 6.5 123 6 112 165 9.1 0 9.3 8.8 07/23/2006 06:00:00 9.9 0.9 12.2 7.6 10 1 12.2 7.6 9.6 1 11.8 7.2 123 5 124 165 9.1 0 9.3 9 07/23/2006 06:10:00 10 1.2 13 7.2 10.2 1.2 13.3 7.2 9.7 1.3 12.6 6.1 121 6 124 165 9.1 0 9.3 9 07/23/2006 06:20:00 11.3 1.1 14.9 6.8 11.5 1.1 15.3 7.2 11.1 1.3 14.1 7.2 121 7 129 165 9 0 9.3 8.5 07/23/2006 06:30:00 11.1 1.3 15.3 8.4 11.2 1.3 14.9 8.8 10.8 1.4 15.3 7.2 127 8 142 165 9 0 9 9 07/23/2006 06:40:00 11.7 1.3 15.3 8.4 11.7 1.2 15.3 8.4 11.3 1.3 15.3 8.4 129 7 121 165 9 0 9 8.5 07/23/2006 06:50:00 12.2 1 14.9 9.9 12.4 1 14.9 9.9 11.8 1 14.9 8 122 6 127 165 9 0 9 8.5 07/23/2006 07:00:00 10.8 1.3 14.1 6.8 11 1.3 14.5 7.2 10.6 1.3 13.7 7.2 121 6 123 165 9.1 0 9.3 9 07/23/2006 07:10:00 11 1 13.7 8 11.2 1 14.1 8 10.7 1.2 13.3 7.6 121 6 123 165 9.1 0 9.3 9 07/23/2006 07:20:00 11.8 1.1 14.9 8 12 1.2 15.3 8.4 11.7 1.2 14.5 8 122 5 109 165 9 0 9 8.8 07/23/2006 07:30:00 10.9 1.1 13.3 7.6 11 1.1 13.7 7.6 10.6 1.1 13.3 7.2 119 6 122 165 9 0 9.3 9 07/23/2006 07:40:00 10.3 1.2 13.3 6.5 10.5 1.2 13.3 7.2 9.9 1.3 13.7 6.8 119 6 116 165 9 0 9.3 9 07/23/2006 07:50:00 10.8 1.1 13.7 8 10.9 1.1 14.1 8 10.4 1.1 14.9 8 121 6 110 165 9 0 9 8.5 07/23/2006 08:00:00 10.4 1.3 13.3 7.2 10.5 1.3 13.7 6.8 10.1 1.4 13.3 6.5 121 9 121 165 8.9 0 9 8.8 07/23/2006 08:10:00 10.9 1 13.3 8 11 1 13.3 8 10.5 1.1 13.3 7.2 122 7 130 165 8.9 0 9 8.8 07/23/2006 08:20:00 9.8 1.1 12.6 7.2 10 1.1 12.6 7.2 9.6 1.3 13.3 6.1 121 6 128 165 8.9 0 9 8.8 07/23/2006 08:30:00 11.3 2 14.9 6.5 11.5 2 15.3 6.8 10.8 1.9 15.3 6.8 119 8 119 165 8.9 0 9 8.8 07/23/2006 08:40:00 11.4 2.3 15.3 6.1 11.6 2.3 15.6 5.3 10.9 2.3 15.6 5.7 111 8 104 165 8.9 0 9.3 8.8 07/23/2006 08:50:00 11.5 1.2 14.9 8.4 11.7 1.2 15.3 8.8 11 1.2 14.5 7.6 113 7 108 165 8.9 0 9 8.8 07/23/2006 09:00:00 11.8 1.3 14.9 8 12 1.3 14.9 8 11.2 1.4 14.9 6.8 113 6 116 165 8.9 0 9 8.8 07/23/2006 09:10:00 11.5 1.4 15.6 6.8 11.7 1.4 16.1 6.8 11 1.5 16.1 7.2 110 7 102 165 8.9 0 9 8.8 07/23/2006 09:20:00 11.9 1 14.1 8.4 12.1 1 14.5 8.4 11.3 1.2 14.5 8.4 110 6 110 165 8.9 0 9 8.8 07/23/2006 09:30:00 11.7 1.2 14.5 8 12 1.2 14.9 8.8 11.1 1.3 14.9 8 108 6 102 165 8.8 0 9 8.8 07/23/2006 09:40:00 12.3 1.2 15.3 9.1 12.5 1.2 16.1 9.1 11.7 1.2 14.5 8.4 104 5 108 165 8.7 0 9 8.5 07/23/2006 09:50:00 12.7 1 15.3 9.1 12.9 1 15.6 9.5 12.2 1.1 14.9 8.8 105 5 105 165 8.6 0 8.8 8.5 07/23/2006 10:00:00 11.5 1.5 14.9 5.3 11.7 1.6 15.3 5.3 10.7 1.7 15.3 4.9 107 7 102 165 8.7 0 9 8.5 07/23/2006 10:10:00 12.3 1.4 15.6 8.8 12.6 1.5 15.6 8.8 11.6 1.6 15.3 8 108 7 102 165 8.8 0 9 8.5 07/23/2006 10:20:00 12.7 1.2 16.1 9.1 13 1.3 16.8 9.1 12.2 1.5 15.6 7.6 105 6 100 165 8.8 0 9 8.5 07/23/2006 10:30:00 12.4 1.3 14.9 8 12.6 1.3 15.6 8.4 11.6 1.5 14.9 7.2 105 6 101 165 8.8 0 9 8.5 07/23/2006 10:40:00 12.3 1.2 15.6 9.5 12.6 1.2 16.1 9.9 11.5 1.4 15.6 7.6 106 7 114 165 8.8 0 9 8.3 07/23/2006 10:50:00 13 1.3 16.1 8.8 13.3 1.3 16.1 9.1 12.2 1.3 15.3 8.4 106 7 87 165 8.7 0 8.8 8.5 07/23/2006 11:00:00 12.9 1.1 15.6 9.1 13.2 1.2 16.1 9.1 12 1.3 14.9 8.4 105 6 102 165 8.7 0 8.8 8.3 07/23/2006 11:10:00 13.1 1.3 15.6 9.5 13.4 1.2 16.1 9.5 12.3 1.4 15.6 8.4 105 6 97 165 8.7 0 9 8.5 07/23/2006 11:20:00 13.2 1.3 17.6 9.1 13.5 1.4 17.9 9.1 12.4 1.5 16.1 8 107 7 99 165 8.7 0 8.8 8.8 07/23/2006 11:30:00 13.3 1.3 16.8 9.1 13.6 1.3 17.2 8.4 12.7 1.4 16.8 8.4 107 6 106 165 8.7 0 8.8 8.5 07/23/2006 11:40:00 13.2 1.2 16.4 9.5 13.5 1.2 16.8 9.5 12.4 1.5 16.1 8.4 108 5 112 165 8.8 0 9 8.5 07/23/2006 11:50:00 13 1.4 16.4 9.1 13.3 1.4 16.4 9.5 12.3 1.5 15.6 7.2 105 6 102 165 8.9 0 9 8.8 07/23/2006 12:00:00 13.5 1.3 16.8 9.1 13.8 1.3 16.8 9.9 12.7 1.5 17.2 8.8 104 6 102 165 8.9 0 9 8.8 07/23/2006 12:10:00 14 1.5 17.2 9.9 14.3 1.5 17.9 9.9 13 1.6 16.4 8.8 104 6 102 165 8.9 0 9 8.8 07/23/2006 12:20:00 14.4 1.6 17.6 8.4 14.7 1.7 17.9 8.8 13.6 1.7 16.8 9.1 105 6 106 165 8.9 0 9 8.8 07/23/2006 12:30:00 14.7 1.5 18.3 9.1 15 1.5 17.9 9.9 13.7 1.5 17.2 9.1 106 6 108 165 8.9 0 9 8.5 07/23/2006 12:40:00 14.9 1.7 19.5 10.7 15.2 1.7 19.5 10.3 13.9 1.7 17.6 8.8 106 7 103 165 8.9 0 9 8.5 07/23/2006 12:50:00 15.3 1.6 18.7 9.9 15.6 1.6 19.1 9.9 14.5 1.7 19.1 8.8 105 6 104 165 8.9 0 9 8.5 07/23/2006 13:00:00 14.6 1.5 19.1 10.3 14.9 1.5 19.9 10.3 13.8 1.6 19.1 10.3 107 7 98 165 8.9 0 9 8.5 07/23/2006 13:10:00 13.9 1.6 17.6 9.1 14.2 1.6 17.6 9.5 12.9 1.7 17.2 9.1 104 7 94 165 8.9 0 9 8.5 07/23/2006 13:20:00 15 1.7 19.1 10.3 15.3 1.7 19.5 9.1 14 1.7 18.7 9.1 104 7 99 165 9 0 9 8.5 07/23/2006 13:30:00 15 1.5 18.3 10.7 15.3 1.6 19.1 11.1 13.9 1.7 17.6 9.5 102 6 95 165 9 0 9 8.5 07/23/2006 13:40:00 15.4 1.4 19.9 11.1 15.8 1.5 20.6 11.1 14.6 1.7 19.9 10.7 103 6 116 165 9 0 9 8.8 07/23/2006 13:50:00 15.3 1.8 20.2 10.3 15.6 1.8 20.2 10.3 14.4 1.9 18.7 10.3 103 6 99 165 9 0 9 8.8 07/23/2006 14:00:00 15.6 1.6 19.1 10.7 15.9 1.6 19.5 11.8 14.5 1.7 18.7 9.5 103 7 110 165 9 0 9.3 8.8 07/23/2006 14:10:00 15.7 1.6 21 10.7 16 1.6 21.4 10.7 14.7 1.7 20.2 9.1 106 7 108 165 9 0 9 8.8 07/23/2006 14:20:00 15.8 1.9 21 10.3 16.2 1.9 21.8 9.9 14.9 1.8 20.2 9.5 104 8 110 165 9 0 9 8.8 07/23/2006 14:30:00 14.8 1.6 19.1 9.5 15.1 1.7 19.5 9.1 13.9 1.9 17.9 8.8 105 7 97 165 9 0 9 8.8 07/23/2006 14:40:00 15.6 1.8 19.9 10.7 15.9 1.8 19.9 11.1 14.7 2.1 19.9 9.1 104 6 106 165 9 0 9 8.8 07/23/2006 14:50:00 16.8 1.8 21 10.3 17.1 1.9 21.4 10.3 15.7 2 20.6 11.1 107 7 106 165 9 0 9 8.5 07/23/2006 15:00:00 15.3 1.9 20.6 9.1 15.6 2 21 9.5 14.4 1.9 19.1 7.6 107 7 97 165 9 0 9 9 07/23/2006 15:10:00 15.5 1.8 20.2 10.7 15.9 1.9 20.6 9.5 14.6 1.8 19.1 9.9 106 7 102 165 9 0 9 8.8 07/23/2006 15:20:00 15.5 2.3 20.6 9.5 15.8 2.3 21.8 10.3 14.4 2.5 19.9 8.4 109 8 102 165 9 0 9 8.8 07/23/2006 15:30:00 16.1 1.3 19.9 11.5 16.4 1.3 20.2 12.2 15.2 1.6 19.1 10.3 108 6 111 165 9 0 9 8.8 07/23/2006 15:40:00 15.3 1.6 19.1 11.1 15.6 1.6 19.5 11.5 14.1 1.8 18.3 9.9 107 6 102 165 9 0.1 9 8.8 07/23/2006 15:50:00 15.1 1.5 18.3 10.7 15.5 1.5 18.7 11.1 14.2 1.8 18.7 9.5 105 7 92 165 9 0.1 9.3 8.5 07/23/2006 16:00:00 15.1 1.8 21 8.4 15.5 1.9 21 8.4 14.4 1.8 19.1 9.5 104 7 108 165 9.1 0 9.3 8.8 07/23/2006 16:10:00 15.6 1.6 19.5 9.9 15.9 1.7 19.5 10.7 14.5 1.8 19.5 9.1 103 6 103 165 9.1 0 9.3 8.8 07/23/2006 16:20:00 15.1 1.7 19.1 10.3 15.4 1.7 19.5 10.3 14.2 1.7 18.7 9.5 105 7 98 165 9.1 0 9.3 8.8 07/23/2006 16:30:00 14.7 1.7 18.7 9.1 15 1.7 19.5 9.5 13.8 1.8 18.3 9.5 103 7 108 165 9.1 0 9.3 8.8 07/23/2006 16:40:00 15.2 1.3 18.7 9.9 15.5 1.4 19.1 10.3 14.3 1.5 18.3 9.5 100 6 107 165 9.2 0 9.3 8.8 07/23/2006 16:50:00 15.1 1.6 20.2 9.9 15.3 1.6 20.6 9.9 14 1.5 17.6 10.3 101 6 85 165 9.2 0 9.3 9 07/23/2006 17:00:00 15.8 1.3 19.5 11.1 16.1 1.3 19.9 11.5 14.6 1.5 18.3 10.3 101 6 102 165 9.2 0 9.3 9 07/23/2006 17:10:00 14.9 1.5 18.7 9.5 15.2 1.5 19.1 9.9 13.9 1.6 18.3 9.9 101 7 106 165 9.3 0 9.3 9 07/23/2006 17:20:00 15 1.6 19.1 10.3 15.3 1.6 19.9 9.5 14.1 1.7 19.1 9.1 100 7 105 165 9.3 0 9.3 9.3 07/23/2006 17:30:00 15.4 1.5 19.1 9.9 15.7 1.6 19.5 9.9 14.4 1.7 18.7 9.5 103 7 114 165 9.3 0 9.3 9.3 07/23/2006 17:40:00 15.6 1.5 19.5 10.7 16 1.5 19.5 11.1 14.7 1.5 18.3 10.3 101 7 94 165 9.4 0 9.6 9.3 07/23/2006 17:50:00 14.8 1.7 19.1 10.3 15.1 1.7 19.9 9.9 13.9 1.7 18.7 9.1 104 6 104 165 9.4 0 9.6 9.3 07/23/2006 18:00:00 14.8 1.5 18.7 9.9 15.1 1.5 18.7 10.3 14 1.5 17.6 9.9 103 6 102 165 9.4 0 9.6 9.3 07/23/2006 18:10:00 15.6 1.9 19.9 9.1 15.9 1.9 20.2 9.9 14.7 2 19.1 9.9 102 6 105 165 9.4 0 9.6 9.3 07/23/2006 18:20:00 15.8 1.6 20.2 11.5 16.1 1.6 20.2 11.5 14.9 1.7 18.7 10.3 102 6 88 165 9.4 0 9.6 9.3 07/23/2006 18:30:00 15.4 1.4 19.1 11.1 15.7 1.5 19.5 11.1 14.5 1.7 18.3 9.9 100 6 105 165 9.4 0 9.6 9.3 07/23/2006 18:40:00 15.3 1.4 19.5 11.1 15.6 1.4 19.5 11.5 14.4 1.5 18.3 10.7 102 7 106 165 9.4 0 9.6 9.3 07/23/2006 18:50:00 15.3 1.5 18.3 11.1 15.6 1.5 18.7 11.5 14.1 1.7 17.9 9.1 101 6 107 165 9.4 0 9.6 9.3 07/23/2006 19:00:00 15 1.7 18.3 9.9 15.3 1.7 18.7 9.5 14.1 1.7 17.9 9.9 100 7 105 165 9.4 0 9.6 9.3 07/23/2006 19:10:00 15.1 1.7 19.1 9.9 15.4 1.7 19.1 10.3 14.2 1.7 19.1 9.5 100 7 102 165 9.4 0 9.6 9.3 07/23/2006 19:20:00 14.6 1.7 18.3 9.5 15 1.7 18.3 9.5 13.8 1.6 17.9 9.1 99 7 108 165 9.4 0 9.6 9.3 07/23/2006 19:30:00 14.5 1.5 17.6 10.7 14.8 1.5 17.9 10.7 13.6 1.7 17.6 8.8 97 7 104 165 9.4 0 9.6 9.3 07/23/2006 19:40:00 14.8 1.6 18.3 9.5 15.1 1.6 18.7 10.3 13.8 1.6 17.9 9.9 99 7 111 165 9.4 0 9.6 9.3 07/23/2006 19:50:00 14.4 1.5 18.3 10.3 14.7 1.5 18.7 9.9 13.5 1.7 17.6 9.1 98 7 93 165 9.4 0 9.6 9.3 07/23/2006 20:00:00 13.7 1.6 17.2 9.5 14 1.7 17.6 8.8 12.6 1.7 16.4 8 96 7 102 165 9.4 0 9.6 9.3 07/23/2006 20:10:00 13.9 1.8 18.7 9.5 14.2 1.9 18.7 9.5 12.7 1.7 17.6 8.4 95 8 94 165 9.4 0 9.6 9.3 07/23/2006 20:20:00 13.7 1.7 18.3 8.4 14 1.7 18.3 9.5 12.8 1.7 18.3 9.1 93 7 97 165 9.4 0 9.6 9.3 07/23/2006 20:30:00 13.6 1.5 17.6 9.9 13.9 1.5 17.9 9.9 12.8 1.6 17.2 8 92 7 94 165 9.4 0 9.6 9.3 07/23/2006 20:40:00 13.6 1.5 17.6 9.1 13.9 1.6 17.9 9.5 12.6 1.4 16.1 9.5 92 8 89 165 9.4 0 9.6 9.3 07/23/2006 20:50:00 13.8 1.5 17.6 8.4 14.1 1.5 17.6 8.4 13 1.5 16.1 8 92 6 96 165 9.4 0 9.6 9.3 07/23/2006 21:00:00 13.3 1.3 16.8 9.5 13.6 1.4 17.2 9.5 12.5 1.5 16.1 8.8 92 6 94 165 9.4 0 9.6 9.3 07/23/2006 21:10:00 13.2 1.5 15.6 8.4 13.4 1.5 16.1 8.4 12.4 1.5 16.1 8 91 6 102 165 9.4 0 9.6 9.3 07/23/2006 21:20:00 13.1 1.4 16.8 9.1 13.4 1.5 17.2 9.5 12.4 1.5 15.6 8 92 7 83 165 9.5 0 9.6 9.3 07/23/2006 21:30:00 13.4 1.2 16.1 9.5 13.7 1.3 16.4 9.5 12.7 1.3 16.4 9.1 91 7 88 165 9.5 0 9.6 9.3 07/23/2006 21:40:00 13.2 1.1 16.1 9.9 13.5 1.2 16.4 9.1 12.3 1.3 15.6 8 92 6 87 165 9.5 0 9.6 9.3 07/23/2006 21:50:00 12.9 1.4 16.1 9.1 13.3 1.5 16.8 9.1 12.2 1.5 15.6 8 92 7 91 165 9.5 0 9.6 9.3 07/23/2006 22:00:00 12.7 1.3 16.4 8.8 13 1.3 16.8 9.1 12 1.5 15.3 7.2 93 7 96 165 9.5 0 9.6 9.3 07/23/2006 22:10:00 12.1 1.7 16.1 8.8 12.4 1.7 16.4 8.8 11.3 1.6 16.1 7.6 94 8 81 165 9.6 0 9.6 9.3 07/23/2006 22:20:00 13.1 1.2 15.6 9.1 13.4 1.3 16.4 8.8 12.5 1.5 15.3 7.6 91 6 100 165 9.6 0 9.6 9.6 07/23/2006 22:30:00 12.7 1.3 15.6 8.8 13 1.3 16.1 8.8 12 1.5 15.3 6.8 92 7 97 165 9.6 0 9.6 9.6 07/23/2006 22:40:00 12.5 1.5 15.6 8 12.8 1.5 16.1 7.6 11.9 1.5 15.3 7.6 93 7 93 165 9.6 0 9.6 9.6 07/23/2006 22:50:00 12 1.4 14.9 6.8 12.2 1.5 15.3 6.8 11.3 1.5 14.5 7.2 94 6 97 165 9.6 0 9.6 9.6 07/23/2006 23:00:00 11.6 1.4 14.9 7.6 11.9 1.5 15.3 6.8 11 1.5 14.1 6.5 93 7 112 165 9.6 0 9.8 9.6 07/23/2006 23:10:00 11.6 1.2 14.1 7.6 12 1.2 14.5 7.2 11.1 1.3 14.1 8 91 6 81 165 9.6 0 9.6 9.6 07/23/2006 23:20:00 12.3 1 14.9 9.5 12.6 1 15.6 9.9 11.6 1.1 14.5 8 90 5 84 165 9.6 0 9.6 9.6 07/23/2006 23:30:00 12 1 14.5 9.1 12.3 1 14.9 9.5 11.4 1.1 14.1 7.2 90 6 87 165 9.6 0 9.6 9.6 07/23/2006 23:40:00 12.2 1 14.5 9.1 12.5 1 14.9 9.5 11.5 1.1 14.5 8.8 89 5 95 165 9.6 0 9.6 9.6 07/23/2006 23:50:00 12 1 13.7 8.8 12.3 1 14.1 9.1 11.2 1.1 13.3 8.4 88 5 95 165 9.6 0 9.6 9.6 07/24/2006 00:00:00 12 1 14.9 8.8 12.4 1 15.3 8.4 11.3 1.1 13.7 8 88 5 88 165 9.6 0 9.8 9.3 07/24/2006 00:10:00 12 0.8 13.3 8.8 12.3 0.8 13.7 9.1 11.2 1 13.7 7.6 88 5 88 165 9.6 0 9.8 9.6 07/24/2006 00:20:00 12.2 0.9 13.7 9.5 12.5 0.9 14.1 9.9 11.6 1.1 13.7 8 88 4 89 165 9.6 0 9.8 9.6 07/24/2006 00:30:00 12.4 0.7 13.7 9.5 12.8 0.7 14.1 9.1 11.8 1 13.7 9.1 89 4 83 165 9.6 0 9.8 9.6 07/24/2006 00:40:00 12.2 0.8 13.7 8.8 12.5 0.8 13.7 8.8 11.7 0.9 13.3 8.8 89 3 90 165 9.6 0 9.8 9.6 07/24/2006 00:50:00 11.8 0.7 13 8.8 12.1 0.7 13.7 9.1 11.3 0.9 13 8.4 90 5 85 165 9.6 0 9.8 9.6 07/24/2006 01:00:00 11.6 0.7 13.3 9.1 11.9 0.7 13.7 9.5 11.2 0.8 13 8.4 90 4 92 165 9.6 0 9.8 9.6 07/24/2006 01:10:00 11.3 0.7 13 8.4 11.7 0.7 13.3 8.8 10.9 0.9 12.6 7.6 90 4 90 165 9.7 0 9.8 9.6 07/24/2006 01:20:00 11.1 0.6 13 9.1 11.4 0.6 13.3 9.1 10.6 1 12.6 8 91 4 89 165 9.7 0 9.8 9.6 07/24/2006 01:30:00 10.9 0.7 12.6 8.4 11.3 0.7 13 8.4 10.4 0.9 12.2 6.8 93 4 94 165 9.7 0 9.8 9.6 07/24/2006 01:40:00 10.5 0.7 12.2 8.4 10.8 0.8 12.2 8 9.8 0.9 12.2 6.5 93 4 94 165 9.7 0 9.8 9.6 07/24/2006 01:50:00 9.8 0.7 11.1 6.8 10.1 0.7 11.5 6.8 9.1 1 11.1 6.5 93 5 98 165 9.8 0 9.8 9.6 07/24/2006 02:00:00 9.1 0.8 10.7 6.1 9.4 1 11.1 6.1 8.6 1 10.7 6.5 92 6 92 165 9.8 0 9.8 9.6 07/24/2006 02:10:00 9 0.6 10.7 6.8 9.2 0.6 11.1 7.2 8.5 0.7 10.3 6.5 91 5 92 165 9.7 0 9.8 9.6 07/24/2006 02:20:00 8.6 0.7 9.9 5.7 8.8 0.8 10.3 6.1 8.1 0.8 9.9 5.3 93 5 93 165 9.7 0 9.8 9.6 07/24/2006 02:30:00 7.9 0.7 9.1 5.7 8.1 0.7 9.5 5.7 7.6 0.8 9.1 5.3 92 5 91 165 9.7 0 9.8 9.6 07/24/2006 02:40:00 7.5 0.5 8.8 6.1 7.7 0.5 8.8 5.7 7.1 0.6 8.4 5.3 92 5 89 165 9.6 0 9.8 9.6 07/24/2006 02:50:00 7.3 0.5 8.4 4.9 7.5 0.5 8.4 5.3 7 0.7 8.4 4.6 92 4 91 165 9.6 0 9.8 9.6 07/24/2006 03:00:00 6.5 0.6 7.6 4.6 6.7 0.5 8 4.6 6.2 0.6 7.6 4.6 90 5 98 165 9.6 0 9.8 9.6 07/24/2006 03:10:00 5.9 0.4 6.8 4.6 6.2 0.4 7.2 4.9 5.7 0.5 6.8 3.4 91 5 94 165 9.6 0 9.8 9.6 07/24/2006 03:20:00 5.9 0.4 6.8 4.9 6.1 0.4 7.2 4.6 5.7 0.5 6.8 3.8 91 4 92 165 9.6 0 9.8 9.6 07/24/2006 03:30:00 5.4 0.4 6.5 4.2 5.6 0.5 6.5 4.2 5.3 0.6 6.5 3.8 95 4 90 165 9.6 0 9.6 9.6 07/24/2006 03:40:00 4.7 0.3 5.3 3.8 4.9 0.3 5.7 3.8 4.7 0.4 5.3 3 94 3 91 165 9.6 0 9.6 9.6 07/24/2006 03:50:00 4 0.3 4.9 3 4.2 0.3 4.9 3.4 4.1 0.4 4.9 3 96 4 92 165 9.6 0 9.6 9.6 07/24/2006 04:00:00 3.6 0.2 4.2 3 3.8 0.2 4.6 3 3.6 0.4 4.2 2.3 102 2 102 165 9.6 0 9.6 9.6 07/24/2006 04:10:00 2.7 0.3 3.4 1.9 3 0.3 3.8 2.3 2.9 0.3 3.8 1.9 96 6 105 165 9.6 0 9.8 9.6 07/24/2006 04:20:00 2 0.4 3 0.4 2.2 0.5 3.4 0.4 2.1 0.4 3 1.1 71 13 74 165 9.6 0 9.6 9.6 07/24/2006 04:30:00 1.9 0.3 2.6 0.7 1.8 0.3 2.3 1.1 1.9 0.3 2.6 1.1 38 9 35 165 9.6 0 9.6 9.6 07/24/2006 04:40:00 1.9 0.4 2.6 0.7 1.8 0.4 2.6 0.7 2 0.4 2.6 1.1 25 2 27 165 9.6 0 9.6 9.6 07/24/2006 04:50:00 1.8 0.4 2.6 0.7 1.7 0.5 2.6 0.7 1.7 0.4 2.6 0.4 22 4 21 165 9.6 0 9.6 9.6 07/24/2006 05:00:00 1.9 0.3 2.6 1.1 1.7 0.4 2.3 0.7 1.9 0.4 2.6 1.1 20 4 24 165 9.6 0 9.6 9.6 07/24/2006 05:10:00 2.1 0.3 2.6 1.1 2.1 0.3 2.6 1.1 2.1 0.4 3 1.1 32 3 30 165 9.6 0 9.6 9.6 07/24/2006 05:20:00 2.4 0.3 3 1.5 2.3 0.3 3 1.5 2.3 0.4 3.4 1.1 23 4 26 165 9.5 0 9.6 9.3 07/24/2006 05:30:00 2.5 0.4 3.4 1.5 2.3 0.5 3 1.1 2.5 0.4 3 1.5 19 6 23 165 9.5 0 9.6 9.3 07/24/2006 05:40:00 3 0.4 3.8 2.3 2.5 0.6 3.8 0.7 3 0.5 4.2 1.9 16 4 12 165 9.5 0 9.6 9.3 07/24/2006 05:50:00 3.2 0.3 3.8 2.3 2.9 0.3 3.8 1.9 3.2 0.4 4.2 1.9 20 4 19 165 9.5 0 9.6 9.3 07/24/2006 06:00:00 2.5 0.4 3.4 1.5 2.3 0.4 3.4 1.1 2.2 0.5 3.4 1.1 24 4 28 165 9.5 0 9.6 9.3 07/24/2006 06:10:00 2.2 0.3 3 1.1 2 0.4 3 1.1 2.1 0.4 3 1.1 25 5 29 165 9.6 0 9.6 9.6 07/24/2006 06:20:00 2.1 0.3 2.6 1.1 1.8 0.4 2.6 0.7 2.2 0.4 3 1.1 19 4 27 165 9.6 0 9.6 9.6 07/24/2006 06:30:00 2 0.3 2.6 1.5 1.6 0.5 2.6 0.4 2.4 0.3 3.4 1.9 13 5 18 165 9.6 0 9.8 9.6 07/24/2006 06:40:00 2.2 0.2 2.6 1.5 1.4 0.3 2.3 0.4 2.7 0.2 3.4 1.9 11 3 9 165 9.6 0 9.8 9.6 07/24/2006 06:50:00 2.2 0.3 2.6 1.5 1.4 0.5 2.3 0.4 2.6 0.3 3.4 1.9 11 2 10 165 9.6 0 9.8 9.6 07/24/2006 07:00:00 3 0.4 3.8 1.9 2.5 0.5 3.4 0.7 3.3 0.3 4.2 2.3 15 3 16 165 9.6 0 9.8 9.6 07/24/2006 07:10:00 3.5 0.3 4.2 2.3 3.1 0.4 3.8 1.5 3.6 0.4 4.6 2.6 17 4 18 165 9.8 0 10.1 9.6 07/24/2006 07:20:00 3.5 0.4 4.6 2.3 3.3 0.5 4.2 1.5 3.6 0.4 4.6 2.3 22 6 37 165 10 0 10.1 9.8 07/24/2006 07:30:00 4.3 0.5 5.3 2.6 4.1 0.5 4.9 2.6 4.2 0.5 5.3 3 28 5 18 165 10 0 10.3 9.8 07/24/2006 07:40:00 4.4 0.5 5.3 3 4.3 0.5 5.3 2.6 4.3 0.6 5.7 2.3 30 4 27 165 10.1 0 10.3 9.8 07/24/2006 07:50:00 4.2 0.5 5.3 3 4.1 0.5 4.9 2.6 4.2 0.6 5.3 2.3 31 6 36 165 10 0 10.3 9.8 07/24/2006 08:00:00 4.3 0.5 5.3 2.6 4.1 0.6 5.3 2.6 4.1 0.7 5.3 2.3 33 5 32 165 10 0 10.3 9.8 07/24/2006 08:10:00 4.1 0.5 4.9 2.3 4 0.5 4.9 1.9 4.1 0.6 5.3 2.3 34 5 37 165 9.9 0 10.1 9.8 07/24/2006 08:20:00 4 0.4 4.9 2.6 3.9 0.4 4.6 2.6 4 0.5 4.9 2.6 33 5 29 165 9.8 0 10.1 9.6 07/24/2006 08:30:00 3.7 0.4 4.6 2.6 3.5 0.5 4.2 2.3 3.5 0.5 4.6 2.3 29 8 28 165 10 0 10.3 9.8 07/24/2006 08:40:00 3.7 0.4 4.6 2.3 3.5 0.5 4.6 1.9 3.6 0.5 4.6 1.9 29 8 36 165 10.2 0 10.6 10.1 07/24/2006 08:50:00 3.5 0.6 4.6 1.5 3.4 0.6 4.6 1.5 3.5 0.6 4.9 1.5 31 8 31 165 10.3 0 10.6 10.3 07/24/2006 09:00:00 3.3 0.4 4.6 1.9 3.2 0.5 4.6 1.9 3.2 0.6 4.6 1.1 34 6 22 165 10.3 0 10.6 10.3 07/24/2006 09:10:00 3.5 0.4 4.9 1.5 3.3 0.5 4.6 1.1 3.5 0.6 4.9 1.1 30 6 37 165 10.3 0 10.6 10.3 07/24/2006 09:20:00 3.5 0.4 4.2 2.3 3.3 0.4 4.2 1.9 3.4 0.5 4.6 1.9 27 7 36 165 10.2 0 10.6 10.1 07/24/2006 09:30:00 3.4 0.4 4.2 1.9 3.2 0.4 3.8 1.9 3.3 0.5 4.2 1.5 26 6 23 165 10.3 0 10.6 10.3 07/24/2006 09:40:00 3.5 0.3 4.2 2.6 3.3 0.3 3.8 2.6 3.4 0.4 4.2 1.5 29 5 28 165 10.4 0 10.6 10.3 07/24/2006 09:50:00 3.4 0.3 4.2 2.6 3.4 0.3 4.2 2.6 3.3 0.3 3.8 2.3 33 4 29 165 10.4 0 10.6 10.3 07/24/2006 10:00:00 2.7 0.7 4.6 0.7 2.7 0.7 4.6 0.7 2.6 0.8 4.6 0.4 30 8 27 165 10.9 0.1 11.1 10.6 07/24/2006 10:10:00 2.2 0.5 3.4 0.7 2.2 0.4 3 0.7 2.2 0.5 3.4 0.4 38 8 22 165 11 0 11.1 10.9 07/24/2006 10:20:00 1.1 0.4 2.3 0.4 0.9 0.4 1.9 0.4 0.8 0.5 1.9 0.4 47 17 40 165 10.9 0 11.4 10.9 07/24/2006 10:30:00 0.9 0.5 2.3 0.4 0.7 0.5 2.3 0.4 0.5 0.4 2.3 0.4 69 30 51 165 11 0 11.4 10.9 07/24/2006 10:40:00 1.6 0.6 3 0.4 1.5 0.7 3 0.4 1.2 0.7 3 0.4 89 28 124 165 10.9 0 11.7 10.9 07/24/2006 10:50:00 1.9 0.4 3 0.7 1.7 0.5 3 0.4 1.5 0.6 2.6 0.4 105 9 107 165 11.1 0 11.1 10.9 07/24/2006 11:00:00 1.8 0.6 3.4 0.4 1.7 0.6 3 0.4 1.6 0.7 2.6 0.4 96 20 98 165 11.1 0 11.4 10.9 07/24/2006 11:10:00 1.7 0.4 3 0.7 1.5 0.4 2.6 0.4 1.3 0.6 2.6 0.4 109 8 115 165 10.9 0 11.1 10.9 07/24/2006 11:20:00 1.9 0.5 3 0.7 1.8 0.5 3 0.7 1.4 0.6 2.6 0.4 119 10 135 165 10.9 0 11.1 10.9 07/24/2006 11:30:00 1.5 0.6 3 0.4 1.3 0.6 2.6 0.4 1.1 0.6 2.3 0.4 121 13 111 165 10.7 0 11.1 10.6 07/24/2006 11:40:00 1.5 0.6 3 0.4 1.2 0.6 3 0.4 1.1 0.6 2.3 0.4 137 10 128 165 10.7 0 10.9 10.6 07/24/2006 11:50:00 0.7 0.4 1.9 0.4 0.4 0.2 1.5 0.4 0.4 0.2 1.1 0.4 168 20 147 165 10.7 0 10.9 10.6 07/24/2006 12:00:00 1 0.4 1.9 0.4 0.7 0.3 1.5 0.4 0.5 0.3 1.9 0.4 158 7 164 165 10.5 0 10.9 10.6 07/24/2006 12:10:00 1.2 0.6 2.6 0.4 0.9 0.7 2.6 0.4 0.8 0.7 2.6 0.4 152 12 140 165 10.7 0 10.9 10.6 07/24/2006 12:20:00 1.2 0.4 2.3 0.4 0.9 0.4 1.9 0.4 0.7 0.4 2.3 0.4 136 9 126 165 10.9 0 11.1 10.9 07/24/2006 12:30:00 1.8 0.8 3.8 0.4 1.6 0.9 3.8 0.4 1.5 0.9 3.4 0.4 134 10 133 165 11.1 0 11.4 10.9 07/24/2006 12:40:00 1.6 0.6 3 0.4 1.4 0.7 2.6 0.4 1.4 0.7 3 0.4 136 16 115 165 11.3 0 11.4 11.1 07/24/2006 12:50:00 1.4 0.7 3.4 0.4 1.2 0.8 3 0.4 1 0.7 3 0.4 123 21 126 165 11.5 0.1 11.9 11.1 07/24/2006 13:00:00 1.8 0.6 3 0.4 1.6 0.7 3 0.4 1.6 0.7 3.8 0.4 145 15 165 165 11.6 0 12.2 11.4 07/24/2006 13:10:00 1.6 0.8 3.8 0.4 1.4 0.9 3.8 0.4 1.5 0.9 3.4 0.4 133 12 128 165 11.3 0 11.7 11.1 07/24/2006 13:20:00 2.2 0.5 3.8 1.1 2 0.6 3.4 0.7 2 0.6 3.8 0.4 152 9 170 165 10.7 0.2 11.1 10.6 07/24/2006 13:30:00 2 0.3 3 1.1 1.8 0.3 2.6 0.7 2 0.4 3 0.7 159 8 151 165 10.3 0.1 10.6 10.3 07/24/2006 13:40:00 1.9 0.4 3.4 0.7 1.7 0.5 3.4 0.7 1.7 0.5 2.6 0.4 145 14 141 165 10.2 0 10.3 10.1 07/24/2006 13:50:00 2.2 0.3 3 1.5 2.1 0.3 3 1.1 2 0.4 3 1.1 123 8 115 165 10.3 0 10.6 10.3 07/24/2006 14:00:00 2 0.3 3 1.5 1.8 0.3 2.6 0.7 1.9 0.4 3 1.1 141 7 145 165 10.4 0 10.9 10.3 07/24/2006 14:10:00 1.9 0.4 2.6 1.1 1.6 0.4 2.6 0.7 1.5 0.3 2.3 0.4 136 10 147 165 10.3 0 10.9 10.3 07/24/2006 14:20:00 1.8 0.5 2.6 0.4 1.5 0.5 2.6 0.4 1.2 0.5 2.3 0.4 121 9 121 165 10.8 0 11.1 10.6 07/24/2006 14:30:00 1.1 0.5 2.3 0.4 0.9 0.4 1.5 0.4 0.7 0.5 1.9 0.4 109 13 96 165 11 0 11.4 10.9 07/24/2006 14:40:00 1.3 0.5 2.6 0.4 1 0.5 2.3 0.4 0.7 0.5 2.3 0.4 108 11 89 165 11.4 0.1 11.9 11.1 07/24/2006 14:50:00 1.1 0.5 2.3 0.4 0.8 0.5 1.9 0.4 0.7 0.4 1.9 0.4 123 19 124 165 11.7 0 12.2 11.7 07/24/2006 15:00:00 1.1 0.6 2.6 0.4 0.8 0.5 2.3 0.4 0.8 0.5 2.3 0.4 122 19 141 165 11.7 0.1 12.2 11.4 07/24/2006 15:10:00 1 0.6 3 0.4 0.7 0.6 2.6 0.4 0.7 0.5 2.3 0.4 136 76 110 165 11.9 0.1 12.5 11.7 07/24/2006 15:20:00 0.8 0.6 2.6 0.4 0.6 0.4 2.3 0.4 0.5 0.3 2.3 0.4 45 72 14 165 12.1 0 12.7 11.9 07/24/2006 15:30:00 0.7 0.4 2.3 0.4 0.5 0.3 1.9 0.4 0.4 0.1 1.1 0.4 64 35 39 165 12 0.1 12.2 11.9 07/24/2006 15:40:00 1.2 0.5 3 0.4 0.9 0.6 2.6 0.4 0.9 0.6 2.6 0.4 107 24 113 165 11.9 0 12.2 11.7 07/24/2006 15:50:00 1.9 0.5 3.4 0.7 1.6 0.6 3.4 0.4 1.6 0.5 3 0.4 121 11 128 165 12 0 12.2 11.9 07/24/2006 16:00:00 2.2 0.4 3.4 0.7 2.1 0.5 3 0.4 2.1 0.5 3.4 0.4 123 8 112 165 11.6 0.2 12.2 11.4 07/24/2006 16:10:00 2.7 0.4 3.8 1.5 2.5 0.4 3.8 1.5 2.7 0.4 3.8 1.9 125 6 116 165 11.3 0 11.9 11.4 07/24/2006 16:20:00 2.5 0.4 3.8 1.5 2.3 0.5 3.8 1.1 2.5 0.4 3.8 1.5 123 8 123 165 11.3 0 11.9 11.1 07/24/2006 16:30:00 2.9 0.4 4.2 1.9 2.8 0.4 4.2 1.5 3 0.4 4.2 1.9 129 8 129 165 11 0 11.4 10.9 07/24/2006 16:40:00 2.8 0.5 4.2 1.9 2.6 0.5 4.2 1.5 2.9 0.5 3.8 1.5 133 10 116 165 10.8 0.1 11.1 10.9 07/24/2006 16:50:00 2.2 0.4 3.4 0.7 2 0.4 3 0.7 2.4 0.4 3 1.5 134 8 121 165 10.7 0 10.9 10.6 07/24/2006 17:00:00 2.3 0.4 3.4 1.1 2.1 0.4 3.4 1.1 2.3 0.4 3 1.5 135 7 112 165 10.8 0 11.1 10.9 07/24/2006 17:10:00 2.7 0.5 3.8 1.5 2.5 0.5 3.4 1.1 2.4 0.5 3.4 0.4 112 12 99 165 10.7 0 11.1 10.6 07/24/2006 17:20:00 2 0.4 3 1.1 2 0.4 3 0.7 2 0.5 3.4 0.4 98 8 100 165 10.7 0 11.1 10.6 07/24/2006 17:30:00 1.5 0.4 2.3 0.4 1.4 0.5 2.3 0.4 1.1 0.7 2.3 0.4 87 8 83 165 10.7 0 10.9 10.6 07/24/2006 17:40:00 1.8 0.6 3 0.4 1.6 0.7 3 0.4 1.4 0.8 3 0.4 40 20 37 165 10.8 0 11.1 10.6 07/24/2006 17:50:00 2.6 0.5 3.8 1.5 2.5 0.5 3.8 1.1 2.7 0.5 3.8 1.5 29 9 27 165 10.8 0 11.1 10.9 07/24/2006 18:00:00 1.8 0.4 2.6 0.7 1.7 0.4 2.6 0.7 1.3 0.5 2.3 0.4 34 11 23 165 10.7 0 10.9 10.9 07/24/2006 18:10:00 2.4 0.4 3.4 1.5 2 0.5 3.4 0.7 2.5 0.4 3.8 1.5 15 8 9 165 10.8 0 11.1 10.9 07/24/2006 18:20:00 2.1 0.4 3 1.1 2.1 0.4 3 1.1 1.9 0.5 3 0.4 31 10 10 165 10.9 0.1 11.4 10.9 07/24/2006 18:30:00 2.4 0.4 3.4 1.1 2.4 0.5 3.4 1.1 2.5 0.4 3.8 1.1 41 8 41 165 10.7 0 11.1 10.6 07/24/2006 18:40:00 2.1 0.4 3.4 1.1 2.1 0.5 3.4 0.7 1.9 0.5 3.4 0.4 49 10 47 165 10.7 0 10.9 10.6 07/24/2006 18:50:00 1.9 0.4 2.6 0.7 1.8 0.4 2.6 0.7 2 0.5 3 0.4 39 10 43 165 10.5 0 10.9 10.3 07/24/2006 19:00:00 2.3 0.4 3 1.1 2.1 0.4 3 0.7 2.2 0.6 3.4 0.7 30 7 29 165 10.3 0 10.6 10.3 07/24/2006 19:10:00 1.4 0.6 2.6 0.4 1.2 0.6 2.6 0.4 1.3 0.8 3 0.4 32 16 23 165 10.4 0 10.6 10.3 07/24/2006 19:20:00 1.4 0.5 2.3 0.4 0.9 0.5 2.3 0.4 1.4 0.6 2.6 0.4 9 12 16 165 10.5 0 11.1 10.3 07/24/2006 19:30:00 1.7 0.4 2.6 0.7 1.3 0.5 2.3 0.4 1.6 0.5 2.6 0.4 16 13 27 165 10.3 0 10.6 10.3 07/24/2006 19:40:00 1.3 0.4 1.9 0.4 0.7 0.3 1.5 0.4 1.3 0.4 2.3 0.4 11 8 9 165 10.2 0 10.3 10.1 07/24/2006 19:50:00 1 0.3 1.9 0.4 0.7 0.4 1.9 0.4 0.6 0.3 1.5 0.4 49 23 60 165 10.1 0 10.3 10.1 07/24/2006 20:00:00 1.2 0.4 2.3 0.4 0.9 0.5 1.9 0.4 1 0.5 2.3 0.4 20 22 13 165 10.2 0 10.3 10.3 07/24/2006 20:10:00 1.3 0.5 2.6 0.4 1 0.6 2.6 0.4 0.8 0.5 1.9 0.4 45 43 111 165 10.2 0 10.3 10.1 07/24/2006 20:20:00 1.6 0.4 2.6 0.7 1.4 0.4 2.3 0.4 1.2 0.5 2.6 0.4 139 27 99 165 10.3 0 10.6 10.1 07/24/2006 20:30:00 1.2 0.6 2.6 0.4 1 0.6 2.6 0.4 0.7 0.6 2.3 0.4 127 22 110 165 10.4 0 10.6 10.3 07/24/2006 20:40:00 1.6 0.4 2.3 0.4 1.5 0.4 2.3 0.4 1.4 0.5 2.3 0.4 113 9 97 165 10.5 0 10.6 10.3 07/24/2006 20:50:00 1.1 0.5 1.9 0.4 0.9 0.5 1.9 0.4 0.7 0.5 1.9 0.4 126 5 126 165 10.5 0 10.6 10.3 07/24/2006 21:00:00 0.4 0.1 1.1 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 124 2 132 165 10.5 0 10.6 10.3 07/24/2006 21:10:00 0.5 0.3 1.5 0.4 0.4 0.1 1.1 0.4 0.4 0 0.7 0.4 112 43 154 165 10.4 0 10.6 10.3 07/24/2006 21:20:00 0.5 0.2 1.1 0.4 0.4 0 0.7 0.4 0.4 0 0.4 0.4 143 5 140 165 10.3 0 10.6 10.3 07/24/2006 21:30:00 1.8 0.4 2.6 0.7 1.5 0.5 2.3 0.4 1.4 0.7 2.3 0.4 150 7 154 165 10.4 0 10.6 10.3 07/24/2006 21:40:00 2.4 0.4 3.4 1.5 2.1 0.4 3 1.1 2.2 0.4 3 1.1 155 4 159 165 10.3 0 10.6 10.3 07/24/2006 21:50:00 2.2 0.5 3 1.1 2 0.5 3 0.7 2 0.6 3.4 0.7 155 8 150 165 10.3 0 10.6 10.3 07/24/2006 22:00:00 1.5 0.5 2.6 0.7 1.1 0.5 2.3 0.4 0.9 0.5 2.3 0.4 158 6 162 165 10.2 0 10.6 10.3 07/24/2006 22:10:00 2.6 0.5 3.8 1.5 2.3 0.5 3.4 1.5 2 0.6 3.4 1.1 164 3 164 165 10.2 0 10.3 10.3 07/24/2006 22:20:00 3.5 0.3 4.2 2.6 3.2 0.3 4.2 2.3 3.3 0.3 4.2 2.3 162 2 167 165 10.2 0 10.3 10.1 07/24/2006 22:30:00 3.6 0.5 4.9 2.3 3.4 0.4 4.6 2.3 3.4 0.5 4.6 2.3 161 6 163 165 10.1 0 10.3 10.1 07/24/2006 22:40:00 4.1 0.4 4.9 3 4 0.4 4.6 2.6 4.2 0.4 5.3 2.6 151 3 153 165 10.1 0 10.3 10.1 07/24/2006 22:50:00 4.3 0.3 5.3 3.4 4.1 0.3 4.9 3.4 4.4 0.3 5.7 3.8 144 6 143 165 10.1 0 10.3 10.1 07/24/2006 23:00:00 4.8 0.3 5.7 4.2 4.7 0.3 5.7 3.8 4.8 0.4 5.7 3.8 145 6 151 165 10.1 0 10.3 10.1 07/24/2006 23:10:00 4.4 0.5 5.7 3 4.4 0.5 5.7 3.4 4.5 0.5 6.1 3 140 7 127 165 10.1 0 10.3 10.1 07/24/2006 23:20:00 4.2 0.4 5.3 3 4.2 0.4 5.3 3 4.3 0.4 5.3 3 142 6 136 165 10.1 0 10.3 10.1 07/24/2006 23:30:00 3.4 0.5 4.6 2.3 3.3 0.5 4.6 2.3 3.5 0.6 4.9 1.9 142 9 148 165 10.1 0 10.3 10.1 07/24/2006 23:40:00 3.2 0.4 4.2 1.9 3.2 0.4 4.2 1.9 3.4 0.4 4.6 1.9 148 8 138 165 10 0 10.3 9.8 07/24/2006 23:50:00 3.7 0.4 4.9 3 3.6 0.4 4.6 2.6 3.7 0.3 4.6 2.6 153 9 164 165 10 0 10.1 9.8 07/25/2006 00:00:00 3.9 0.5 4.9 2.3 3.8 0.5 4.9 2.3 3.9 0.4 4.9 2.6 160 12 164 165 10 0 10.3 9.8 07/25/2006 00:10:00 4 0.4 5.3 3 4 0.4 4.9 3 4.2 0.4 5.3 3.4 163 8 183 165 10 0 10.3 9.8 07/25/2006 00:20:00 4.2 0.4 5.3 3 4.1 0.4 4.9 3 4.3 0.4 5.3 3 159 8 148 165 10 0 10.3 9.8 07/25/2006 00:30:00 4.1 0.7 6.1 2.6 3.9 0.6 5.7 2.3 4.1 0.8 6.1 2.3 167 9 164 165 9.9 0 10.1 9.6 07/25/2006 00:40:00 4.6 0.7 6.1 3 4.4 0.6 5.7 3 4.6 0.7 6.1 3 164 7 173 165 9.7 0 9.8 9.6 07/25/2006 00:50:00 5.5 0.6 6.8 4.2 5.3 0.5 6.5 4.2 5.6 0.7 7.2 4.2 161 6 161 165 9.6 0 9.8 9.6 07/25/2006 01:00:00 5.3 0.7 7.2 3.8 5.1 0.7 6.8 3.4 5.3 0.7 6.8 3.4 168 8 166 165 9.6 0 9.8 9.6 07/25/2006 01:10:00 5 0.5 6.8 3.4 4.9 0.5 6.5 3.4 5.1 0.5 6.5 3.8 164 11 170 165 9.6 0 9.8 9.6 07/25/2006 01:20:00 5 0.9 7.2 2.6 5 0.9 6.8 2.6 5.3 0.8 7.2 3.4 161 8 165 165 9.6 0 9.8 9.6 07/25/2006 01:30:00 6.4 0.3 7.2 5.3 6.2 0.4 7.2 5.3 6.4 0.5 7.6 4.9 166 11 165 165 9.4 0 9.6 9.3 07/25/2006 01:40:00 6.4 0.3 7.2 5.3 6.2 0.3 7.2 5.3 6.5 0.5 7.2 4.9 166 11 165 165 9.2 0 9.3 9 07/25/2006 01:50:00 6.4 0.3 7.2 5.7 6.2 0.3 6.8 5.3 6.5 0.4 7.2 5.3 163 15 164 165 9.2 0 9.3 9 07/25/2006 02:00:00 6.1 0.3 6.8 4.9 6 0.3 6.5 4.9 6.3 0.4 6.8 4.9 164 3 166 165 9.1 0 9.3 9 07/25/2006 02:10:00 5.5 0.5 6.5 4.6 5.4 0.4 6.5 4.6 5.5 0.5 7.2 4.2 160 5 161 165 9.1 0 9.3 9 07/25/2006 02:20:00 5.4 0.5 6.8 4.2 5.4 0.5 6.8 4.2 5.5 0.5 7.2 4.6 156 6 160 165 9.1 0 9.3 9 07/25/2006 02:30:00 5.6 0.4 6.5 3.8 5.5 0.4 6.5 4.2 5.8 0.4 6.5 4.6 157 3 152 165 9 0 9 9 07/25/2006 02:40:00 5.1 0.4 6.1 4.2 5.1 0.4 6.1 4.2 5.2 0.4 6.1 4.2 155 3 157 165 9 0 9 9 07/25/2006 02:50:00 3.9 0.3 4.6 3.4 3.9 0.3 4.6 3 3.9 0.4 4.9 3 147 5 153 165 9 0 9 9 07/25/2006 03:00:00 4.3 0.5 5.7 3 4.4 0.5 5.7 3.4 4.3 0.5 5.3 2.6 136 5 129 165 9 0 9 9 07/25/2006 03:10:00 4.8 0.7 6.5 3 4.9 0.7 6.5 3 4.7 0.7 6.1 3 139 7 143 165 9 0 9 9 07/25/2006 03:20:00 5.7 0.5 7.2 4.2 5.7 0.5 7.2 4.2 5.6 0.6 7.2 3.8 139 7 147 165 9 0 9 9 07/25/2006 03:30:00 6.7 0.6 8.4 4.6 6.7 0.7 8.4 4.9 6.3 0.8 8 3.4 136 7 135 165 9.1 0 9.3 9 07/25/2006 03:40:00 6.8 0.7 8.4 4.6 6.7 0.7 8.8 4.9 6.6 0.7 8 4.2 139 7 139 165 9.1 0 9.3 9 07/25/2006 03:50:00 6.8 0.8 8.4 4.2 6.8 0.8 8.8 4.6 6.6 0.8 8.4 4.9 133 7 129 165 9.1 0 9.3 9 07/25/2006 04:00:00 7.3 0.6 8.8 5.3 7.4 0.6 8.8 4.9 7.1 0.6 8.4 5.3 133 5 134 165 9 0 9.3 8.8 07/25/2006 04:10:00 7.1 0.6 8.4 5.7 7.2 0.6 8.8 5.3 6.9 0.6 8.4 5.3 132 5 128 165 8.9 0 9 9 07/25/2006 04:20:00 6.7 0.6 8.4 5.3 6.9 0.6 8.4 5.3 6.6 0.6 8 4.9 132 5 135 165 9 0 9 9 07/25/2006 04:30:00 7.2 0.6 8.8 5.3 7.2 0.6 9.1 5.3 7 0.6 8.4 4.6 137 6 129 165 9 0 9 9 07/25/2006 04:40:00 7 0.7 9.1 5.3 7.1 0.7 9.1 5.3 6.8 0.8 8.8 4.6 135 7 141 165 9 0 9 9 07/25/2006 04:50:00 6.5 0.5 8 4.9 6.6 0.5 8 5.3 6.3 0.6 8 4.6 138 7 137 165 9 0 9 8.8 07/25/2006 05:00:00 6.2 0.6 8 4.9 6.4 0.6 8 4.6 6.1 0.6 8 4.2 131 6 129 165 9 0 9 8.8 07/25/2006 05:10:00 5.7 0.6 6.8 3.8 5.8 0.6 6.8 4.2 5.6 0.6 6.8 3.8 135 6 128 165 8.9 0 9 8.8 07/25/2006 05:20:00 6.1 0.6 7.2 4.2 6.2 0.6 7.6 3.8 5.9 0.7 7.6 3.8 130 5 123 165 8.9 0 9 8.8 07/25/2006 05:30:00 6.1 0.7 7.6 4.2 6.1 0.7 7.6 4.2 5.9 0.7 7.6 3.8 132 7 142 165 8.9 0 9 8.8 07/25/2006 05:40:00 5.5 0.6 6.5 3.8 5.6 0.6 6.8 3.8 5.4 0.6 6.8 3.4 133 8 135 165 9 0 9 9 07/25/2006 05:50:00 5.8 0.6 6.8 4.2 5.9 0.6 7.2 4.6 5.7 0.6 6.8 4.2 133 6 134 165 9 0 9 9 07/25/2006 06:00:00 5.2 0.5 6.5 3.4 5.3 0.6 6.5 3.4 5 0.6 6.1 3.4 132 7 124 165 9 0 9 9 07/25/2006 06:10:00 5.6 0.6 6.8 3.8 5.7 0.6 6.8 4.2 5.4 0.6 6.8 3.8 127 4 125 165 9 0 9.6 8.8 07/25/2006 06:20:00 4.9 0.6 6.8 3.8 5 0.6 6.8 3.4 4.7 0.6 6.5 3.4 128 6 131 165 9 0 9 9 07/25/2006 06:30:00 5 0.4 6.1 3.8 5.2 0.5 6.1 3.8 4.8 0.5 6.1 3.4 118 5 122 165 9 0 9 9 07/25/2006 06:40:00 4.5 0.5 5.7 3 4.6 0.5 6.1 3 4.2 0.5 5.3 2.6 114 6 114 165 9.1 0 9.3 9 07/25/2006 06:50:00 4.2 0.4 5.3 3 4.3 0.5 5.3 3 4 0.5 4.9 2.6 108 5 107 165 9.1 0 9.3 9 07/25/2006 07:00:00 3.7 0.5 4.9 2.3 3.8 0.5 4.9 2.3 3.6 0.5 4.6 2.3 98 6 105 165 9.2 0 9.3 9 07/25/2006 07:10:00 3.8 0.5 4.6 2.6 3.9 0.5 4.9 2.3 3.4 0.6 4.6 1.9 94 5 89 165 9.3 0 9.3 9 07/25/2006 07:20:00 3.8 0.4 4.6 2.6 3.9 0.4 4.9 2.6 3.5 0.5 4.9 1.9 94 6 103 165 9.3 0 9.3 9 07/25/2006 07:30:00 3.7 0.5 4.6 2.3 3.8 0.5 4.9 1.9 3.5 0.6 4.6 1.9 88 6 88 165 9.3 0 9.3 9 07/25/2006 07:40:00 3.6 0.5 4.6 2.3 3.8 0.5 4.9 2.3 3.5 0.5 4.6 1.9 85 6 85 165 9.4 0 9.6 9.3 07/25/2006 07:50:00 3.7 0.5 4.9 2.6 3.8 0.5 4.9 2.3 3.6 0.5 4.9 1.9 83 8 79 165 9.5 0 9.6 9.3 07/25/2006 08:00:00 3.5 0.6 4.9 1.9 3.5 0.7 4.9 1.9 3.4 0.6 4.9 1.9 82 8 75 165 9.6 0.1 9.8 9.3 07/25/2006 08:10:00 3.9 0.4 4.9 3 4 0.5 5.3 2.6 3.8 0.5 4.9 2.6 84 8 88 165 9.6 0 9.6 9.6 07/25/2006 08:20:00 3 0.4 4.2 1.9 3 0.5 4.6 1.9 2.9 0.5 4.6 1.5 77 13 73 165 9.8 0 10.1 9.6 07/25/2006 08:30:00 2.6 0.6 4.6 0.7 2.6 0.7 4.6 0.7 2.5 0.6 4.2 0.4 65 15 96 165 9.9 0 10.1 9.6 07/25/2006 08:40:00 2.5 0.7 5.3 1.1 2.4 0.7 4.9 1.1 2.4 0.7 4.6 1.1 53 13 52 165 9.9 0 10.1 9.8 07/25/2006 08:50:00 3.1 0.6 4.9 1.9 3.1 0.6 4.6 1.9 3 0.5 4.6 1.9 52 12 41 165 9.9 0 10.1 9.6 07/25/2006 09:00:00 3.6 0.8 5.7 1.9 3.6 0.8 5.3 1.9 3.5 0.8 5.7 1.9 44 15 39 165 9.8 0 9.8 9.6 07/25/2006 09:10:00 3.4 0.7 5.3 1.9 3.3 0.7 5.7 1.9 3.2 0.8 5.3 1.5 34 10 31 165 10 0 10.3 9.6 07/25/2006 09:20:00 3.9 0.9 5.7 1.9 3.9 0.9 5.7 1.9 3.9 0.9 5.7 1.9 43 9 46 165 10 0 10.3 9.8 07/25/2006 09:30:00 3.7 0.8 5.7 1.9 3.5 0.8 5.7 1.9 3.6 0.8 5.7 1.5 28 12 31 165 10.1 0 10.3 9.8 07/25/2006 09:40:00 4 0.7 5.7 2.3 3.8 0.8 5.7 1.9 3.9 0.7 5.3 2.3 26 9 26 165 10.1 0 10.3 10.1 07/25/2006 09:50:00 3.8 0.7 5.7 1.9 3.6 0.7 5.3 1.9 3.7 0.7 4.9 1.9 28 12 46 165 10.2 0 10.3 10.1 07/25/2006 10:00:00 4 0.7 5.7 2.6 3.7 0.8 5.7 1.9 3.9 0.6 5.7 2.3 25 10 32 165 10.3 0 10.6 10.3 07/25/2006 10:10:00 4.6 0.6 6.1 2.6 4.2 0.8 6.1 1.9 4.5 0.6 5.7 2.6 19 8 23 165 10.2 0 10.3 10.3 07/25/2006 10:20:00 4.9 0.6 6.5 3.4 4.6 0.7 6.1 2.3 4.8 0.7 6.5 3 20 8 21 165 10.3 0 10.6 10.3 07/25/2006 10:30:00 5.6 0.5 7.2 3.8 5.2 0.6 7.2 3 5.6 0.6 7.2 3.8 20 6 21 165 10.2 0 10.6 10.3 07/25/2006 10:40:00 5.7 0.5 6.8 4.2 5.3 0.7 6.8 3 5.7 0.5 7.2 4.2 20 6 11 165 10.3 0 10.6 10.3 07/25/2006 10:50:00 5.8 0.5 6.8 4.2 5.5 0.7 6.8 2.6 5.7 0.6 6.8 3.8 21 6 22 165 10.3 0 10.6 10.3 07/25/2006 11:00:00 5.6 0.5 6.8 4.2 5.2 0.7 6.5 2.6 5.5 0.5 6.8 3.8 21 6 16 165 10.2 0 10.3 10.1 07/25/2006 11:10:00 6.1 0.6 7.6 4.2 5.5 0.8 7.2 3 6.1 0.6 7.2 4.2 17 6 12 165 10.2 0 10.6 10.1 07/25/2006 11:20:00 6.9 0.6 8.4 4.9 6.2 0.8 7.6 3.8 6.9 0.6 8.4 4.9 16 5 11 165 10.4 0 10.9 10.3 07/25/2006 11:30:00 6.8 0.5 8 5.3 6.2 0.7 7.6 3.8 6.8 0.6 8 4.6 16 5 15 165 10.5 0 10.6 10.3 07/25/2006 11:40:00 7 0.4 8 5.7 6.4 0.7 7.6 4.2 7 0.5 8 5.3 17 4 14 165 10.3 0 10.6 10.3 07/25/2006 11:50:00 7.3 0.4 8.4 5.7 6.5 0.7 7.6 3.4 7.4 0.5 8.8 5.7 16 4 17 165 10.3 0 10.6 10.3 07/25/2006 12:00:00 7.4 0.4 8.4 5.7 6.4 1 8 3 7.5 0.5 8.4 5.7 15 4 20 165 10.3 0 10.6 10.3 07/25/2006 12:10:00 7.2 0.4 8.4 5.7 6.3 0.7 7.6 3.8 7.4 0.5 8.8 5.3 15 3 16 165 10.2 0 10.3 10.3 07/25/2006 12:20:00 6.9 0.3 7.6 6.1 5.2 0.8 6.8 3.4 7.2 0.4 8 5.7 12 2 15 165 10.2 0 10.6 10.3 07/25/2006 12:30:00 6.5 0.4 7.2 5.3 4.8 0.9 7.2 3 6.7 0.5 7.6 5.3 11 3 12 165 10.3 0 10.6 10.3 07/25/2006 12:40:00 6.2 0.3 7.2 5.3 4.9 0.9 6.8 2.6 6.4 0.4 7.2 5.3 13 3 15 165 10.3 0 10.6 10.3 07/25/2006 12:50:00 6.3 0.4 7.2 4.9 5.4 0.7 6.8 3 6.4 0.5 7.2 4.9 15 4 15 165 10.5 0 10.6 10.3 07/25/2006 13:00:00 6.4 0.3 7.2 5.3 5.2 0.8 6.8 3 6.6 0.4 7.6 5.3 14 3 18 165 10.5 0 10.9 10.3 07/25/2006 13:10:00 5.7 0.5 6.8 4.2 4 1 6.1 1.9 6.1 0.5 6.8 4.2 11 4 17 165 10.5 0 10.6 10.3 07/25/2006 13:20:00 5.2 0.5 6.8 3.8 3.4 0.8 5.7 1.9 5.5 0.4 6.8 4.2 4 7 5 165 10.6 0 10.9 10.3 07/25/2006 13:30:00 5 0.4 6.5 4.2 3.1 0.7 5.3 1.9 5.3 0.4 6.5 4.2 3 6 3 165 10.7 0 10.9 10.6 07/25/2006 13:40:00 4.6 0.4 5.7 3 3 0.7 4.9 1.9 4.9 0.5 5.7 3.4 4 7 5 165 10.9 0 11.1 10.9 07/25/2006 13:50:00 4.1 0.4 4.9 3 2.4 0.5 4.6 1.1 4.5 0.4 5.7 3.4 3 6 10 165 10.9 0 11.1 10.9 07/25/2006 14:00:00 3.4 0.4 4.6 2.3 2.4 0.6 3.8 1.1 3.8 0.4 4.9 3 7 7 3 165 11.1 0 11.4 10.9 07/25/2006 14:10:00 3.6 0.4 4.6 2.6 2.2 0.6 4.2 0.7 3.8 0.3 4.6 2.6 1 7 14 165 11.1 0 11.4 11.1 07/25/2006 14:20:00 3.1 0.4 3.8 1.9 1.9 0.5 3.8 0.7 3.3 0.4 4.2 2.3 2 8 353 165 11.3 0 11.4 11.1 07/25/2006 14:30:00 2.8 0.4 3.4 1.9 1.7 0.6 3.4 0.4 2.9 0.4 4.2 1.5 5 8 11 165 11.1 0 11.4 11.1 07/25/2006 14:40:00 2.7 0.4 3.4 1.9 1.6 0.5 3 0.7 2.7 0.4 3.8 1.5 3 8 355 165 11.4 0 11.7 10.9 07/25/2006 14:50:00 2.7 0.4 3.8 1.5 1.8 0.6 3.4 0.4 2.6 0.5 3.8 1.1 4 10 18 165 11.6 0 11.7 11.4 07/25/2006 15:00:00 1.9 0.4 3 0.7 1.4 0.6 2.6 0.4 1.9 0.5 3 0.4 351 16 2 165 11.7 0 11.9 11.7 07/25/2006 15:10:00 1.6 0.3 2.3 0.7 1.3 0.5 2.3 0.4 1.6 0.3 2.3 0.7 341 9 332 165 11.6 0 11.9 11.4 07/25/2006 15:20:00 1.5 0.4 2.6 0.4 0.9 0.4 1.9 0.4 1.6 0.5 2.6 0.7 347 7 359 165 11.3 0 11.4 11.4 07/25/2006 15:30:00 1.6 0.4 2.6 0.7 1 0.5 2.6 0.4 1.7 0.5 3 0.4 350 12 344 165 11.3 0 11.4 11.1 07/25/2006 15:40:00 2 0.3 3 1.1 1.6 0.4 2.6 0.7 1.8 0.4 2.6 0.7 340 9 344 165 11.3 0 11.4 11.1 07/25/2006 15:50:00 1.4 0.4 2.3 0.4 0.7 0.4 1.9 0.4 1.1 0.5 2.3 0.4 349 9 12 165 11.3 0 11.4 11.1 07/25/2006 16:00:00 1.9 0.6 3.4 0.7 1.2 0.6 3 0.4 1.4 0.5 2.6 0.4 355 9 355 165 11.6 0.1 11.9 11.1 07/25/2006 16:10:00 1.1 0.6 3 0.4 0.7 0.5 2.6 0.4 0.8 0.6 2.6 0.4 2 7 15 165 11.6 0 11.9 11.7 07/25/2006 16:20:00 1 0.8 3 0.4 0.7 0.6 2.6 0.4 0.7 0.6 2.6 0.4 4 14 9 165 11.4 0.1 11.7 11.1 07/25/2006 16:30:00 0.9 0.4 1.9 0.4 0.5 0.3 1.9 0.4 0.6 0.4 2.6 0.4 341 5 340 165 11.5 0 11.7 11.1 07/25/2006 16:40:00 0.6 0.4 2.3 0.4 0.5 0.3 1.9 0.4 0.5 0.3 1.5 0.4 337 9 332 165 11.5 0 11.7 11.4 07/25/2006 16:50:00 0.8 0.5 1.9 0.4 0.6 0.4 1.9 0.4 0.6 0.5 1.9 0.4 331 13 345 165 11.5 0 11.7 11.4 07/25/2006 17:00:00 0.5 0.2 1.1 0.4 0.4 0.1 1.1 0.4 0.4 0.1 0.7 0.4 331 10 340 165 11.4 0 11.7 11.4 07/25/2006 17:10:00 1.7 0.8 3.4 0.4 1.1 0.8 3.4 0.4 1.4 0.8 3.4 0.4 350 9 340 165 11.2 0 11.4 11.1 07/25/2006 17:20:00 2 0.4 3.4 1.1 1.2 0.5 2.6 0.4 1.7 0.5 2.6 0.4 3 10 354 165 10.9 0 11.1 10.9 07/25/2006 17:30:00 1 0.4 2.3 0.4 0.6 0.3 2.3 0.4 0.5 0.4 2.3 0.4 337 12 354 165 10.9 0 11.1 10.9 07/25/2006 17:40:00 0.7 0.5 2.3 0.4 0.5 0.4 2.3 0.4 0.5 0.3 1.9 0.4 328 19 304 165 11.1 0 11.1 10.9 07/25/2006 17:50:00 4.1 1.5 7.6 1.5 4 1.5 7.2 1.1 3.2 1.2 6.1 0.4 298 9 300 165 10.9 0.1 11.1 10.9 07/25/2006 18:00:00 6.3 0.7 8 4.6 6.2 0.7 8 4.2 5.2 0.9 7.6 3.4 307 7 290 165 10.7 0 10.9 10.6 07/25/2006 18:10:00 6.8 0.8 8.8 4.9 6.7 0.7 8.8 4.9 5.8 0.8 8 3.8 309 7 319 165 10.7 0 11.1 10.6 07/25/2006 18:20:00 8.2 0.8 9.9 6.1 8 0.8 9.9 6.1 7 1 9.5 4.2 309 5 313 165 10.5 0 10.9 10.3 07/25/2006 18:30:00 9.2 0.7 11.1 7.2 9 0.7 11.1 6.8 8.2 0.7 10.3 6.5 311 4 307 165 10.4 0 10.6 10.3 07/25/2006 18:40:00 9.7 0.8 11.8 7.6 9.6 0.8 11.5 7.2 8.3 1 11.1 5.7 309 4 310 165 10.3 0 10.6 10.3 07/25/2006 18:50:00 10 1 12.2 7.2 9.9 1 11.5 7.6 8.2 1 10.7 5.7 307 4 305 165 10.3 0 10.6 10.3 07/25/2006 19:00:00 10 0.8 11.8 7.6 10 0.8 11.8 7.6 8.6 1.1 11.1 5.7 309 5 302 165 10.3 0 10.6 10.3 07/25/2006 19:10:00 9.6 0.7 11.1 7.6 9.5 0.7 11.1 7.6 8.8 0.8 10.7 6.5 312 5 309 165 10.4 0 10.6 10.3 07/25/2006 19:20:00 9.4 0.7 11.5 7.6 9.4 0.8 11.5 7.2 8.4 1 10.7 6.1 311 5 304 165 10.5 0 10.6 10.3 07/25/2006 19:30:00 9.5 0.7 11.5 7.6 9.5 0.8 11.5 8 8.4 0.9 11.5 5.3 310 5 309 165 10.7 0 10.9 10.6 07/25/2006 19:40:00 10 0.8 12.2 7.6 9.9 0.8 11.8 7.6 8.6 1 11.8 5.7 310 7 301 165 10.7 0 10.9 10.6 07/25/2006 19:50:00 9.9 0.8 12.6 8 9.9 0.8 12.2 8 8.4 1 10.7 5.7 309 5 300 165 10.6 0 10.9 10.6 07/25/2006 20:00:00 10.1 0.9 12.2 7.2 10 0.9 11.8 7.2 9 1 11.5 6.1 312 6 304 165 10.5 0 10.6 10.3 07/25/2006 20:10:00 10 0.9 12.6 7.6 9.8 0.9 11.8 7.2 8.6 0.9 11.1 6.1 311 6 299 165 10.4 0 10.6 10.3 07/25/2006 20:20:00 10.6 0.7 12.6 8.8 10.5 0.7 12.2 8.4 9.5 0.9 11.8 6.5 313 6 310 165 10.2 0 10.6 10.3 07/25/2006 20:30:00 10.8 1 13.7 8 10.7 1 13.7 8.8 9.8 1 13 6.8 313 6 309 165 10.2 0 10.3 10.3 07/25/2006 20:40:00 10.2 0.8 12.6 8.4 10.1 0.8 12.6 8 9 0.9 11.8 6.8 311 6 305 165 10.1 0 10.3 10.1 07/25/2006 20:50:00 10.6 0.9 13 8.4 10.5 0.9 13 8 9.2 1 11.5 6.5 311 6 305 165 10.1 0 10.3 10.1 07/25/2006 21:00:00 10.1 1 12.2 7.2 10 1 12.2 6.8 8.8 1.1 12.2 6.1 311 8 316 165 10.1 0 10.3 9.8 07/25/2006 21:10:00 10.6 0.9 12.6 8.4 10.6 0.9 12.6 8.4 9.1 1 12.6 6.5 309 7 307 165 10.1 0 10.3 9.8 07/25/2006 21:20:00 9.6 1 12.2 7.2 9.5 1 12.2 7.2 8.7 1.1 10.7 6.1 313 6 308 165 10 0 10.3 9.8 07/25/2006 21:30:00 9.6 1.3 12.2 4.9 9.5 1.3 11.8 5.3 8.2 1.3 11.1 4.9 309 6 310 165 10 0 10.3 9.8 07/25/2006 21:40:00 10.7 0.7 12.6 8 10.7 0.7 12.2 8.4 8.7 1 11.5 6.1 306 5 297 165 10 0 10.1 9.8 07/25/2006 21:50:00 9.8 0.9 12.2 7.2 9.6 0.9 11.8 7.2 8.3 1.1 11.1 5.7 310 7 301 165 9.9 0 10.1 9.8 07/25/2006 22:00:00 9.5 0.7 11.8 8 9.4 0.7 11.5 7.6 7.9 1 11.8 5.7 308 5 298 165 9.8 0 9.8 9.8 07/25/2006 22:10:00 9.1 1.2 12.6 6.5 9 1.2 12.6 6.5 8.3 1.2 12.6 5.3 312 6 314 165 9.8 0 9.8 9.6 07/25/2006 22:20:00 9.4 0.8 12.6 7.2 9.3 0.8 12.2 7.2 8.2 1.1 12.2 5.3 311 9 324 165 9.9 0 10.3 9.6 07/25/2006 22:30:00 10.1 0.9 12.2 7.6 10 0.9 12.2 8 8.6 1 11.8 6.1 310 7 305 165 9.8 0 9.8 9.6 07/25/2006 22:40:00 9.9 0.9 13 7.6 9.9 1 12.6 7.6 9 1.1 12.2 6.1 312 7 317 165 9.8 0 10.1 9.8 07/25/2006 22:50:00 9.7 1.2 13 6.5 9.6 1.2 12.2 6.5 8.9 1.3 12.6 5.3 316 11 305 165 9.9 0 10.1 9.6 07/25/2006 23:00:00 9.7 1.3 15.3 6.1 9.6 1.3 14.5 5.7 8.8 1.2 12.2 4.9 313 6 309 165 10 0 10.1 9.8 07/25/2006 23:10:00 8.4 1 11.5 6.1 8.3 1 10.7 5.7 7.9 1.1 11.5 4.9 321 11 343 165 10 0 10.6 9.8 07/25/2006 23:20:00 7.9 0.9 10.3 4.6 7.9 0.9 10.3 4.9 7.5 1 10.3 4.9 323 11 322 165 9.9 0 10.1 9.6 07/25/2006 23:30:00 7.4 1.2 12.2 4.2 7.2 1.2 10.7 4.2 7.1 1.2 10.3 4.2 333 17 3 165 10 0 10.1 9.8 07/25/2006 23:40:00 7.6 1 11.1 4.9 7.5 1 10.3 5.3 6.8 1 9.5 3.8 316 10 306 165 10 0 10.1 9.8 07/25/2006 23:50:00 7.9 1.1 10.3 3.8 7.8 1.1 10.3 3.4 6.2 1.2 9.1 2.6 305 11 312 165 9.9 0 10.1 9.6 07/26/2006 00:00:00 8.3 1 11.8 5.7 8.2 1 11.5 5.7 7.2 1.1 9.9 4.9 311 9 321 165 10 0 10.3 9.6 07/26/2006 00:10:00 8.3 1.2 12.6 5.7 8.3 1.2 12.6 5.3 7 1.3 11.5 3.4 309 8 310 165 10 0 10.3 9.8 07/26/2006 00:20:00 7.7 0.9 11.1 5.3 7.6 0.8 10.7 5.3 6.2 0.9 8.8 4.2 305 8 305 165 10.1 0 10.3 9.8 07/26/2006 00:30:00 7.1 1.1 10.7 4.2 7.1 1 10.3 4.2 6.4 1.2 10.3 3.4 315 13 326 165 10.1 0 10.3 9.8 07/26/2006 00:40:00 7.2 1.3 11.5 4.6 7.1 1.2 11.5 3.8 6.5 1.5 11.1 3.4 318 16 349 165 10.1 0 10.3 10.1 07/26/2006 00:50:00 6.4 1.2 9.5 3.8 6.3 1.2 9.9 3.8 5.7 1.2 8.8 2.6 315 13 327 165 10.2 0 10.3 10.3 07/26/2006 01:00:00 6 1 8.8 3.4 5.9 0.9 8.8 3.8 5.3 1 8 2.6 314 8 323 165 10.1 0 10.3 10.1 07/26/2006 01:10:00 6.3 1.2 9.9 3 6 1.1 10.3 2.6 5.8 1.4 9.9 3 323 15 340 165 10.1 0 10.6 10.1 07/26/2006 01:20:00 7.9 1.4 11.1 4.6 7.7 1.3 11.5 4.6 7.6 1.4 10.7 4.2 340 11 350 165 10.1 0 10.3 10.1 07/26/2006 01:30:00 6.9 1.4 10.7 3.4 6.7 1.4 10.3 3 6.3 1.5 9.9 3 328 11 323 165 10.1 0 10.3 10.1 07/26/2006 01:40:00 7.2 1 10.3 4.9 7 1 10.3 4.9 6.9 1 9.5 4.9 335 11 343 165 10.3 0 10.6 10.3 07/26/2006 01:50:00 6.1 1.1 8.8 3.4 5.9 1.1 9.1 3 5.8 1 8 3.4 331 14 340 165 10.4 0 10.6 10.3 07/26/2006 02:00:00 4.2 1.7 7.6 0.4 4.1 1.8 7.2 0.4 3 1.5 6.5 0.4 321 18 324 165 10.1 0 10.6 10.1 07/26/2006 02:10:00 4.1 1.2 6.8 1.9 4 1.3 7.2 1.1 2.8 1.5 6.5 0.4 303 17 304 165 10 0 10.3 9.8 07/26/2006 02:20:00 7.1 2.1 11.8 2.6 7 2 11.1 2.6 4.9 1.9 9.9 1.1 297 11 301 165 9.9 0 10.1 9.8 07/26/2006 02:30:00 9.2 1.3 11.8 5.7 9.1 1.3 11.5 5.7 7.6 1.1 10.7 4.6 309 8 314 165 9.9 0 10.1 9.8 07/26/2006 02:40:00 7.1 1 9.5 4.6 7 1 9.9 4.2 5.8 0.9 8.4 3.8 308 9 300 165 10 0 10.3 9.8 07/26/2006 02:50:00 10.4 1.4 13.3 6.8 10.2 1.3 13 6.5 7.9 1.3 11.8 4.9 303 5 305 165 10 0 10.3 9.8 07/26/2006 03:00:00 10.7 1 13 7.6 10.6 1 12.6 8 9.1 1.1 11.8 5.7 310 4 308 165 10 0 10.3 9.8 07/26/2006 03:10:00 7.5 1.5 10.7 4.2 7.4 1.5 10.3 4.2 6.3 2 9.9 2.3 313 9 326 165 10 0 10.3 9.8 07/26/2006 03:20:00 6.6 1.2 10.3 3 6.5 1.3 10.3 3 5.1 1.2 8.4 1.9 306 9 307 165 10.1 0 10.3 9.8 07/26/2006 03:30:00 7.3 0.8 10.3 4.9 7.2 0.8 9.9 5.3 5.6 1 9.1 3 304 8 318 165 10.5 0.1 10.9 10.3 07/26/2006 03:40:00 8 0.9 10.3 6.1 7.9 0.8 9.9 6.1 6.3 1 9.1 3.8 306 6 312 165 10.5 0 10.9 10.3 07/26/2006 03:50:00 8 1.2 11.1 4.6 7.8 1.2 11.1 4.9 6.5 1.3 9.9 3 310 7 307 165 10.4 0 10.6 10.3 07/26/2006 04:00:00 6.6 1 9.5 4.6 6.6 0.9 9.9 4.2 5.1 1.2 8 2.3 305 10 317 165 10.2 0 10.6 10.1 07/26/2006 04:10:00 8 1 10.7 5.3 7.8 1 10.3 4.9 6 1.1 8.8 3.4 303 7 302 165 10.3 0 10.6 10.3 07/26/2006 04:20:00 8 0.9 9.5 5.7 7.9 0.9 9.9 5.7 6.2 0.8 8.8 4.2 304 5 302 165 10.1 0 10.6 9.8 07/26/2006 04:30:00 8.7 0.8 10.7 6.5 8.6 0.8 10.7 6.5 6.7 1 9.5 4.2 302 5 295 165 10.1 0 10.6 9.8 07/26/2006 04:40:00 10.3 0.6 11.8 8.4 10.3 0.6 11.5 8.4 7.5 0.6 9.1 6.1 301 3 302 165 10.2 0 10.6 10.1 07/26/2006 04:50:00 10 0.7 11.8 8 10 0.7 11.5 8 7.8 0.8 9.9 5.7 306 4 301 165 10.1 0 10.3 10.1 07/26/2006 05:00:00 9.8 0.6 11.1 7.6 9.8 0.6 11.1 7.6 7.5 0.7 9.5 4.9 304 3 306 165 10.2 0 10.6 9.8 07/26/2006 05:10:00 9.3 0.8 10.7 6.8 9.2 0.8 10.7 6.8 7.3 0.8 9.5 4.9 306 4 313 165 10.2 0 10.3 10.1 07/26/2006 05:20:00 9.3 0.6 10.7 7.2 9.1 0.6 10.7 7.6 7.2 0.8 9.1 4.9 303 4 304 165 10.2 0 10.6 10.1 07/26/2006 05:30:00 9.5 0.7 11.1 6.8 9.4 0.7 10.7 6.8 6.9 0.7 8.8 4.9 302 4 309 165 10.6 0.1 10.9 10.3 07/26/2006 05:40:00 9.8 0.7 11.5 7.6 9.8 0.7 11.5 7.2 6.8 0.6 9.1 4.9 300 4 300 165 10.5 0 10.9 10.3 07/26/2006 05:50:00 9.2 0.8 10.7 6.8 9.2 0.8 10.7 6.5 7.5 1 9.9 5.3 308 5 300 165 10.3 0 10.6 10.3 07/26/2006 06:00:00 9.6 0.5 10.7 7.6 9.5 0.6 10.7 7.2 8.7 0.8 10.3 5.7 312 4 310 165 10.2 0 10.6 10.3 07/26/2006 06:10:00 9.8 1 11.8 7.6 9.7 1 11.8 7.2 8.2 1 11.1 6.1 308 5 304 165 10.4 0.1 10.9 10.3 07/26/2006 06:20:00 10.6 0.8 12.2 7.2 10.7 0.8 12.6 7.2 8.3 0.9 10.7 6.1 305 4 301 165 10.9 0 11.1 10.9 07/26/2006 06:30:00 12 0.6 13.3 9.9 12.1 0.6 13.7 10.3 9.1 1 11.5 6.8 296 3 295 165 10.9 0 11.1 10.9 07/26/2006 06:40:00 10.8 1 13.3 8 10.9 1 13.3 7.6 8 1 11.8 5.3 299 5 294 165 11.1 0.1 11.4 10.9 07/26/2006 06:50:00 9.5 1 12.6 6.8 9.6 1 12.2 6.8 8.4 1.3 12.6 4.9 291 5 291 165 11.3 0 11.4 11.4 07/26/2006 07:00:00 9.5 0.9 12.2 7.2 9.6 0.9 12.2 7.2 8.2 1.3 12.2 4.9 291 5 282 165 11.4 0 11.9 11.4 07/26/2006 07:10:00 9 1.5 13.3 4.9 9.1 1.5 13 5.3 7.8 1.5 11.8 4.2 292 6 292 165 11.5 0 12.2 11.4 07/26/2006 07:20:00 8.4 1.7 11.8 4.2 8.4 1.7 12.2 4.6 6.8 1.3 11.1 3.8 300 9 297 165 11.8 0.2 12.2 11.4 07/26/2006 07:30:00 6 1.3 8.8 1.9 6.1 1.3 9.1 1.9 5.9 1.3 9.1 1.9 293 12 300 165 12.4 0 12.5 12.2 07/26/2006 07:40:00 8.2 2 12.6 2.3 8.2 1.9 12.2 3 7.2 1.9 12.6 3 294 11 297 165 12.4 0 12.7 12.2 07/26/2006 07:50:00 9.5 1.1 12.2 6.1 9.6 1.1 12.6 6.1 8.3 1.5 11.8 3.8 292 6 289 165 12.3 0 12.7 12.2 07/26/2006 08:00:00 9 1.3 11.8 5.7 9 1.3 11.8 5.3 7.2 1.3 10.7 3.4 298 8 302 165 12.4 0 13 12.2 07/26/2006 08:10:00 8.3 1.1 11.8 5.7 8.3 1.1 11.5 5.7 7 1.4 12.2 3.8 293 7 287 165 12.8 0.2 13.5 12.5 07/26/2006 08:20:00 7.1 1.1 9.9 3.8 7.2 1.1 10.3 3.8 7.1 1.2 9.9 3.4 283 7 275 165 13.1 0 13.3 13 07/26/2006 08:30:00 7.7 0.7 9.9 5.7 7.8 0.7 9.5 5.7 7.2 1.1 10.7 4.2 289 7 285 165 13.2 0 13.3 13 07/26/2006 08:40:00 7.7 1 10.7 4.2 7.9 1.1 10.3 4.2 7.3 1.3 10.7 3 289 7 285 165 13.3 0 13.5 13 07/26/2006 08:50:00 7.9 1.3 10.3 3.8 8 1.3 10.3 4.2 7.1 1.6 10.7 2.6 294 10 284 165 13.3 0 13.5 13 07/26/2006 09:00:00 8.7 1 11.5 6.5 8.8 1 11.5 6.5 7.7 1.3 11.1 4.2 291 6 278 165 13.5 0 13.5 13.3 07/26/2006 09:10:00 8.9 1.1 11.5 4.9 9 1 11.5 5.7 7.7 1.5 12.2 4.2 291 8 288 165 13.5 0 13.5 13.3 07/26/2006 09:20:00 9.3 0.9 11.1 6.8 9.4 1 11.5 6.8 7.8 1.2 11.5 4.9 297 7 286 165 13.5 0 13.5 13.3 07/26/2006 09:30:00 8.4 1.3 10.7 4.6 8.5 1.3 11.1 5.3 6.9 1.2 9.9 3.8 297 8 291 165 13.7 0 13.8 13.5 07/26/2006 09:40:00 8.3 1.1 10.7 5.7 8.5 1.1 10.7 5.7 7.7 1.3 10.7 4.2 288 7 284 165 13.9 0.1 14.4 13.5 07/26/2006 09:50:00 8.3 1.3 11.5 3.8 8.4 1.3 11.1 4.2 7 1.5 11.1 3.8 295 8 293 165 14.2 0 14.4 13.8 07/26/2006 10:00:00 8.5 1.1 11.5 5.7 8.5 1.1 11.5 6.1 6.7 1 9.9 4.6 299 7 296 165 14.4 0 14.9 14.1 07/26/2006 10:10:00 9.1 0.6 10.3 6.8 9.1 0.6 10.3 7.2 6.9 0.8 9.1 4.9 304 4 305 165 14.3 0 14.9 14.1 07/26/2006 10:20:00 8.4 0.8 10.3 6.1 8.5 0.8 10.7 6.1 6.4 0.7 8.4 4.2 300 6 304 165 14.7 0 15.2 14.4 07/26/2006 10:30:00 8.4 0.7 9.9 6.5 8.5 0.7 10.3 6.5 6.5 0.9 9.1 4.2 297 5 300 165 14.8 0 15.2 14.6 07/26/2006 10:40:00 8.1 0.7 9.9 5.3 8.2 0.7 9.9 5.7 6.5 0.8 9.1 4.2 306 4 305 165 15.2 0.1 15.7 14.9 07/26/2006 10:50:00 7.2 0.7 8.8 5.3 7.3 0.7 8.8 5.3 6 0.8 8.4 4.2 297 7 301 165 15.4 0 15.7 15.2 07/26/2006 11:00:00 6.9 0.9 9.1 4.2 7 0.9 8.8 4.2 5.7 0.8 8 3.4 301 7 309 165 15.4 0.3 16 14.9 07/26/2006 11:10:00 7 0.8 8.8 5.3 7.1 0.8 8.8 5.3 5.8 1 8 3.4 295 5 316 165 15.6 0 16 15.5 07/26/2006 11:20:00 6.8 1.1 9.9 4.9 6.9 1 9.9 4.9 5.5 1.1 8 3.4 301 6 307 165 16 0 16.3 15.7 07/26/2006 11:30:00 5.2 1.1 7.6 1.9 5.3 1.1 7.6 1.9 4.3 1 7.6 1.9 304 10 289 165 16.9 0.4 17.7 16.3 07/26/2006 11:40:00 4.2 0.8 6.1 1.9 4.4 0.8 6.1 1.9 3.5 0.9 5.3 1.1 300 12 301 165 17.8 0 18.2 17.1 07/26/2006 11:50:00 3.8 0.8 6.1 1.5 3.9 0.8 6.1 1.9 3.2 0.8 4.9 1.1 295 17 299 165 18.3 0.2 18.8 17.7 07/26/2006 12:00:00 1.4 1 3.8 0.4 1.5 1 4.2 0.4 1.3 0.7 3.8 0.4 176 98 316 165 17.2 0.4 18.5 16.8 07/26/2006 12:10:00 3.6 0.7 6.1 1.9 3.7 0.7 5.7 1.9 3.1 0.7 4.9 1.5 309 12 301 165 17.3 0.1 17.7 16.8 07/26/2006 12:20:00 2.6 0.7 4.6 1.1 2.7 0.7 4.2 1.1 2 0.7 3.8 0.4 303 17 310 165 17.4 0.4 18.2 16.8 07/26/2006 12:30:00 1.8 1.1 5.3 0.4 1.9 1.2 5.3 0.4 1.5 1.1 4.9 0.4 322 76 296 165 17 0.4 18.2 16.6 07/26/2006 12:40:00 1.8 0.9 4.6 0.4 1.9 0.8 4.6 0.4 2.1 0.7 3.8 0.4 135 58 313 165 16.3 0.1 16.8 16 07/26/2006 12:50:00 2.3 0.5 3.4 1.1 2.4 0.5 3.4 0.7 2.5 0.4 3.4 1.5 129 22 106 165 15.8 0.2 16.3 15.5 07/26/2006 13:00:00 3.1 0.9 5.3 1.1 3.2 1 5.3 1.1 3.1 0.8 4.9 1.1 140 18 128 165 15.2 0.2 15.7 14.4 07/26/2006 13:10:00 2.9 0.6 4.6 1.9 2.9 0.6 4.9 1.9 3.1 0.6 4.6 1.9 152 16 165 165 14.4 0.4 15.2 13.5 07/26/2006 13:20:00 2.7 0.5 4.2 1.5 2.8 0.4 4.2 1.5 2.9 0.5 4.2 1.9 157 12 189 165 13.7 0.3 14.4 13.3 07/26/2006 13:30:00 3.1 0.7 4.9 1.5 3.2 0.7 4.9 1.9 3.3 0.8 4.9 1.5 160 12 164 165 15 0.6 16 13.8 07/26/2006 13:40:00 4 1 6.5 1.5 4.1 1 6.5 1.9 4.3 0.9 6.8 2.3 144 13 140 165 15.7 0 16 15.2 07/26/2006 13:50:00 4.2 0.5 6.5 3 4.2 0.6 6.8 3 4.4 0.6 6.8 3 139 11 113 165 15.5 0.4 16.6 14.9 07/26/2006 14:00:00 4.3 0.5 5.7 2.6 4.3 0.6 5.7 2.6 4.6 0.5 5.7 3.4 145 9 153 165 15.9 0 16.6 15.7 07/26/2006 14:10:00 3.8 0.5 5.3 3 3.8 0.5 5.3 2.3 4 0.6 5.7 2.3 139 10 147 165 15.7 0.1 16.3 15.5 07/26/2006 14:20:00 3.6 0.8 5.3 1.5 3.7 0.7 5.7 2.3 3.9 0.7 5.7 1.9 142 10 130 165 16 0 16.3 15.7 07/26/2006 14:30:00 3.1 0.5 4.9 1.5 3.2 0.6 4.9 1.9 3.4 0.6 4.9 1.9 135 11 141 165 16.5 0.2 16.8 16 07/26/2006 14:40:00 3.1 0.5 4.9 2.3 3.1 0.6 4.9 1.9 3.4 0.6 5.3 2.3 147 10 160 165 16.2 0.2 16.8 15.5 07/26/2006 14:50:00 2.8 0.6 4.2 1.1 2.9 0.6 4.6 1.1 3.1 0.6 4.6 1.1 139 13 135 165 16.3 0.1 16.8 15.7 07/26/2006 15:00:00 3.3 0.5 5.3 1.9 3.3 0.5 5.7 2.3 3.6 0.5 5.3 2.3 140 8 150 165 16.5 0 16.8 16.3 07/26/2006 15:10:00 3 0.6 5.3 1.1 3 0.6 5.3 1.1 3.3 0.6 5.3 2.3 146 12 156 165 16.9 0 17.1 16.6 07/26/2006 15:20:00 2.3 0.6 3.8 0.7 2.4 0.6 4.2 0.7 2.6 0.6 3.8 1.1 150 11 163 165 16.7 0.1 17.1 16.3 07/26/2006 15:30:00 2.7 0.5 4.2 1.1 2.8 0.5 4.2 1.1 2.9 0.5 4.2 1.5 151 13 147 165 17.1 0.1 17.4 16.8 07/26/2006 15:40:00 2 0.6 3.4 0.7 2.1 0.6 3.4 0.7 2.5 0.5 3.4 1.1 148 10 135 165 16.3 0.3 17.1 15.7 07/26/2006 15:50:00 1.9 0.7 3.4 0.7 2 0.6 3.4 0.7 2.3 0.5 3.4 1.1 158 9 154 165 15.2 0.2 16 14.9 07/26/2006 16:00:00 1.6 0.4 2.6 0.7 1.9 0.4 3 1.1 2 0.4 3.4 1.5 146 7 139 165 14.9 0.1 15.5 14.6 07/26/2006 16:10:00 1.6 0.8 4.2 0.4 1.9 0.8 4.6 0.4 1.8 0.7 3.8 0.4 127 22 122 165 16.6 0.6 17.4 15.5 07/26/2006 16:20:00 1.8 0.9 3.8 0.4 2 0.8 4.2 0.4 2.2 0.6 4.6 0.4 155 18 176 165 16.9 0.3 17.4 16.3 07/26/2006 16:30:00 1.4 0.7 3.4 0.4 1.7 0.6 3.4 0.4 1.9 0.6 3.4 0.4 146 17 145 165 16.9 0.1 17.1 16.3 07/26/2006 16:40:00 2.3 0.7 3.8 0.4 2.5 0.7 4.2 0.7 2.6 0.7 4.2 0.7 136 16 143 165 16.5 0.3 17.1 16 07/26/2006 16:50:00 1.6 0.5 3 0.4 1.9 0.5 3.4 0.4 1.9 0.5 3.4 0.7 121 11 125 165 15.8 0.3 16.3 15.2 07/26/2006 17:00:00 1.6 0.6 2.6 0.4 1.9 0.6 3 0.4 1.7 0.6 3 0.4 107 8 105 165 15.2 0 15.5 15.2 07/26/2006 17:10:00 0.7 0.3 1.5 0.4 0.9 0.4 1.9 0.4 1 0.5 1.9 0.4 140 32 94 165 15.2 0.1 15.5 14.9 07/26/2006 17:20:00 0.7 0.4 2.3 0.4 1.1 0.5 3 0.4 1.3 0.4 2.6 0.4 118 19 64 165 15.1 0 15.5 14.9 07/26/2006 17:30:00 1.2 0.5 3 0.4 1.5 0.5 3 0.4 1.6 0.5 2.6 0.4 113 28 90 165 15 0 15.5 14.9 07/26/2006 17:40:00 0.6 0.5 2.6 0.4 0.7 0.6 3 0.4 1.1 0.7 4.6 0.4 126 22 94 165 15 0 15.2 14.6 07/26/2006 17:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0.2 1.1 0.4 140 0 165 165 14.9 0 15.2 14.6 07/26/2006 18:00:00 0.4 0.1 1.1 0.4 0.4 0.2 1.5 0.4 0.4 0 0.7 0.4 171 53 300 165 15.6 0.2 16 15.2 07/26/2006 18:10:00 0.5 0.5 3.8 0.4 0.5 0.6 4.2 0.4 0.5 0.5 3.4 0.4 264 17 293 165 15.5 0.1 16.3 15.2 07/26/2006 18:20:00 3.3 0.5 4.6 1.5 3.4 0.6 4.6 1.5 2.6 0.6 4.2 1.1 295 9 295 165 16.8 0.2 17.4 16.3 07/26/2006 18:30:00 3.1 0.7 4.9 0.7 3.2 0.7 4.9 1.5 2.5 0.8 4.2 0.4 296 12 292 165 17.5 0.2 18 17.1 07/26/2006 18:40:00 3.3 0.7 4.9 1.5 3.4 0.7 5.3 1.9 2.8 0.7 4.2 1.1 298 12 292 165 17.2 0 17.4 16.8 07/26/2006 18:50:00 3.1 0.8 4.9 1.1 3.3 0.8 4.9 1.5 2.7 0.8 5.3 0.7 292 11 305 165 16.7 0 17.1 16.6 07/26/2006 19:00:00 3.9 1 6.1 1.5 4.1 0.9 6.1 2.6 3.5 0.8 6.1 1.5 291 11 293 165 16.1 0.2 16.8 15.7 07/26/2006 19:10:00 4.2 0.6 5.7 2.6 4.4 0.6 5.7 3 3.7 0.6 5.3 2.3 296 8 302 165 15.8 0 16.3 15.7 07/26/2006 19:20:00 5.7 0.8 7.2 3.4 5.8 0.7 7.6 3.8 4.5 0.7 6.8 2.6 299 6 291 165 15.6 0 16 15.5 07/26/2006 19:30:00 6 0.5 7.2 4.6 6.1 0.5 7.6 4.9 4.8 0.7 6.8 3.4 296 6 296 165 15.2 0.1 15.7 15.2 07/26/2006 19:40:00 6.9 0.7 9.1 4.9 7.1 0.7 9.1 4.9 5.6 0.9 8 3.4 295 5 295 165 15 0 15.5 14.9 07/26/2006 19:50:00 6.9 0.7 8.8 4.2 7 0.8 8.8 4.2 5.3 0.7 8 3.8 297 5 296 165 14.7 0.1 15.2 14.6 07/26/2006 20:00:00 6.9 0.9 9.1 4.6 7 0.9 9.1 4.6 5.4 0.9 8 3.4 297 5 289 165 14.4 0 14.9 14.4 07/26/2006 20:10:00 7.7 0.8 9.5 5.7 7.7 0.8 9.5 5.3 5.8 0.7 8.8 4.2 302 5 302 165 14.2 0 14.6 14.1 07/26/2006 20:20:00 7.3 0.6 8.8 5.7 7.4 0.6 9.1 5.7 5.7 0.7 7.6 3.8 302 5 301 165 14 0 14.1 13.8 07/26/2006 20:30:00 7.6 0.5 9.1 5.7 7.6 0.5 9.1 6.1 5.8 0.7 7.6 3.8 301 4 301 165 13.7 0.1 14.1 13.5 07/26/2006 20:40:00 7.4 0.6 9.1 5.7 7.3 0.6 8.8 5.7 5.6 0.6 7.6 3.8 300 5 305 165 13.5 0 13.8 13.3 07/26/2006 20:50:00 7 0.5 8.8 5.3 6.9 0.5 8.8 5.3 5.2 0.6 6.8 3.8 302 4 295 165 13.3 0 13.5 12.7 07/26/2006 21:00:00 6.8 0.6 9.1 5.3 6.8 0.6 9.1 5.3 5.4 0.8 8 3.4 298 6 296 165 13.1 0 13.3 12.7 07/26/2006 21:10:00 6.4 0.6 8.4 4.9 6.6 0.6 8.4 4.9 4.9 0.7 7.6 3.4 299 5 300 165 12.7 0 13.3 12.5 07/26/2006 21:20:00 6.4 0.6 8.8 4.9 6.5 0.6 8.8 5.3 5 0.8 7.2 3 300 5 291 165 12.6 0 13 12.5 07/26/2006 21:30:00 6.3 0.7 8.4 4.6 6.4 0.7 8.4 4.9 4.8 0.7 7.2 3 298 5 292 165 12.6 0.1 13 12.5 07/26/2006 21:40:00 6.3 0.6 7.6 4.6 6.4 0.6 7.6 4.9 4.8 0.6 6.5 3 299 5 305 165 12.4 0 12.5 12.5 07/26/2006 21:50:00 5.5 0.4 6.5 4.2 5.6 0.4 6.5 4.6 5 0.8 6.1 3 308 7 296 165 12.3 0 12.5 12.2 07/26/2006 22:00:00 5.3 0.7 6.8 3.8 5.4 0.6 6.8 3.8 5 0.7 6.1 3 308 6 301 165 12.4 0 12.5 11.9 07/26/2006 22:10:00 4.5 0.5 6.1 3.4 4.7 0.5 6.1 3.4 4.1 0.5 5.3 2.6 308 6 307 165 12.4 0 13 11.9 07/26/2006 22:20:00 4.7 0.4 5.7 3.8 4.8 0.4 5.7 3.8 3.6 0.5 5.3 2.6 300 4 302 165 12.5 0 12.7 11.9 07/26/2006 22:30:00 4.7 0.4 5.7 3.8 4.9 0.3 5.7 4.2 3.9 0.5 5.7 2.6 292 4 289 165 12.5 0 12.7 12.2 07/26/2006 22:40:00 3.8 0.7 5.3 1.9 4 0.7 5.3 2.3 3.2 0.7 4.9 1.5 292 6 288 165 12.7 0 13 12.2 07/26/2006 22:50:00 3 0.6 4.2 1.5 3.1 0.6 4.6 1.5 2.6 0.6 3.8 1.1 295 8 287 165 12.8 0 13 12.5 07/26/2006 23:00:00 4.9 1 6.8 3 5 1 6.8 3.4 4.2 1 6.5 2.3 292 8 293 165 12.6 0 12.7 11.9 07/26/2006 23:10:00 5.2 0.5 6.5 4.2 5.3 0.5 6.5 4.2 4.3 0.8 6.5 2.6 293 5 291 165 12.4 0 12.7 12.2 07/26/2006 23:20:00 4.9 0.6 6.5 3.4 5 0.6 6.5 3.4 4.5 0.8 6.5 2.6 288 7 296 165 12.5 0 12.7 12.5 07/26/2006 23:30:00 4.3 0.6 5.7 2.3 4.4 0.6 5.7 2.3 3.7 0.8 6.1 2.3 294 7 307 165 12.6 0 12.7 12.5 07/26/2006 23:40:00 4.5 0.6 6.1 3 4.6 0.6 6.5 3.4 4.1 0.6 6.1 2.6 290 4 291 165 12.4 0 12.5 12.2 07/26/2006 23:50:00 4.3 0.5 5.3 3 4.5 0.5 5.7 3 3.8 0.7 5.3 1.9 291 5 296 165 12.3 0 12.5 12.2 07/27/2006 00:00:00 4.6 0.5 5.7 3.4 4.7 0.5 6.1 3.4 4.2 0.6 5.7 2.6 287 5 291 165 12.2 0 12.5 11.9 07/27/2006 00:10:00 4.4 0.6 5.7 2.6 4.6 0.6 6.1 2.6 4.1 0.9 5.7 1.9 290 6 283 165 12.3 0 12.5 12.2 07/27/2006 00:20:00 4.2 0.4 4.9 3 4.4 0.4 5.3 3.4 4 0.5 5.3 2.6 288 4 290 165 12.2 0 12.5 11.9 07/27/2006 00:30:00 3.8 0.4 4.6 2.6 4 0.4 4.9 3 3.8 0.5 5.3 2.3 287 5 290 165 12.2 0 12.2 11.9 07/27/2006 00:40:00 3.8 0.4 4.9 2.6 4 0.4 4.9 3 3.3 0.7 4.9 1.9 292 7 304 165 12.2 0 12.5 12.2 07/27/2006 00:50:00 3.2 0.5 4.6 2.3 3.3 0.5 4.6 2.3 2.6 0.6 4.2 1.5 293 6 304 165 12.1 0 12.5 11.9 07/27/2006 01:00:00 3 0.4 3.8 1.9 3.1 0.4 4.2 2.3 2.3 0.5 3.8 1.1 293 5 291 165 12.1 0 12.5 11.9 07/27/2006 01:10:00 3.2 0.4 4.2 2.3 3.3 0.4 4.2 2.3 2.3 0.5 3.8 0.7 295 5 292 165 12.3 0 12.5 11.9 07/27/2006 01:20:00 3.2 0.4 4.2 2.3 3.3 0.4 4.2 2.3 2.4 0.4 3.4 1.5 294 5 295 165 12.3 0 12.5 12.2 07/27/2006 01:30:00 3 0.5 4.2 1.9 3.1 0.5 4.2 1.9 2.4 0.4 3.4 1.1 296 4 295 165 12.3 0 12.5 12.2 07/27/2006 01:40:00 2.9 0.4 3.8 1.9 3 0.4 3.8 1.9 2.2 0.4 3.4 1.5 298 4 297 165 12.3 0.1 12.5 12.2 07/27/2006 01:50:00 2.4 0.3 3 1.5 2.5 0.3 3 1.9 2.3 0.4 3.4 1.5 290 5 305 165 12.3 0 12.5 12.2 07/27/2006 02:00:00 1.8 0.2 2.3 1.1 1.9 0.3 2.6 1.5 1.7 0.4 2.6 0.7 289 2 292 165 12.6 0 13 12.2 07/27/2006 02:10:00 2.4 0.3 3.4 1.5 2.5 0.3 3.4 1.9 2.2 0.5 4.2 1.1 291 5 284 165 12.5 0.1 12.7 12.2 07/27/2006 02:20:00 2.4 0.3 3 1.5 2.4 0.4 3 1.5 2.4 0.4 3.4 1.5 289 3 291 165 12.3 0 12.5 11.9 07/27/2006 02:30:00 3 0.4 3.8 1.9 3.1 0.4 4.2 1.9 3.2 0.4 4.2 2.3 286 5 290 165 12.3 0 12.5 12.2 07/27/2006 02:40:00 3.3 0.4 4.6 2.3 3.4 0.4 4.9 2.6 2.9 0.6 4.2 1.5 292 6 278 165 12.2 0.1 12.5 11.9 07/27/2006 02:50:00 2.5 0.4 3.8 1.9 2.6 0.4 3.8 1.9 2.5 0.4 3.8 1.5 289 5 298 165 12.1 0.2 12.5 11.7 07/27/2006 03:00:00 2.2 0.4 3.4 1.1 2.3 0.4 3.4 1.1 2.3 0.5 3.4 1.1 286 5 287 165 12.3 0.1 12.5 11.9 07/27/2006 03:10:00 1.7 0.4 2.6 0.7 1.8 0.5 2.6 0.7 1.9 0.4 3 0.7 287 4 279 165 12.1 0.1 12.5 11.7 07/27/2006 03:20:00 1.8 0.6 3 0.4 1.9 0.6 3.4 0.4 2.2 0.6 3.4 0.4 283 4 278 165 12.3 0.1 12.5 11.7 07/27/2006 03:30:00 3.3 0.6 4.9 1.9 3.4 0.6 4.6 2.3 3.1 0.8 4.6 1.5 289 5 292 165 11.9 0.2 12.2 11.4 07/27/2006 03:40:00 3.4 0.5 4.9 2.3 3.5 0.5 4.9 2.3 3.3 0.6 4.6 1.1 289 5 284 165 11.9 0.1 12.2 11.4 07/27/2006 03:50:00 2.9 0.7 4.9 1.5 3 0.6 4.9 1.9 2.6 0.7 4.6 0.7 291 6 293 165 12 0 12.2 11.7 07/27/2006 04:00:00 2.1 0.4 3.4 1.5 2.3 0.4 3.4 1.5 2.5 0.4 3.8 1.5 291 4 284 165 11.8 0.2 12.2 11.4 07/27/2006 04:10:00 2.4 0.6 3.8 1.1 2.5 0.6 3.8 1.1 2.7 0.5 3.8 1.1 290 6 293 165 11.7 0.2 11.9 11.4 07/27/2006 04:20:00 2.6 0.6 4.2 1.5 2.7 0.6 4.2 1.5 2.7 0.6 4.2 1.5 287 4 285 165 11.8 0.2 12.2 11.4 07/27/2006 04:30:00 3.4 0.5 4.6 2.3 3.5 0.5 5.3 2.3 3.4 0.6 4.9 1.9 291 4 285 165 11.8 0.2 12.2 11.4 07/27/2006 04:40:00 4.4 0.5 6.1 3.4 4.4 0.5 5.7 3.4 3.4 0.6 5.3 2.3 296 4 298 165 11.7 0.2 12.2 11.1 07/27/2006 04:50:00 3.8 0.4 4.9 2.6 3.8 0.4 5.3 3 3.8 0.5 5.3 2.3 291 5 279 165 11.8 0.2 12.2 11.4 07/27/2006 05:00:00 3.2 0.4 4.2 1.9 3.3 0.4 4.6 2.3 2.9 0.6 4.6 1.9 298 6 298 165 12 0 12.2 11.7 07/27/2006 05:10:00 3.2 0.5 4.9 1.9 3.3 0.5 4.9 1.9 2.6 0.6 4.2 1.5 296 7 294 165 12.1 0.2 12.5 11.7 07/27/2006 05:20:00 1.9 0.6 3.4 0.7 2 0.6 3.4 0.7 2 0.4 3 0.7 301 8 313 165 12 0.2 12.5 11.7 07/27/2006 05:30:00 1 0.7 3.4 0.4 1 0.8 3.8 0.4 1.6 0.8 3.8 0.4 298 14 281 165 12.3 0.2 12.7 11.7 07/27/2006 05:40:00 2.8 0.7 4.2 0.7 2.9 0.7 4.6 1.1 2.8 0.7 4.9 1.1 295 8 287 165 12.5 0.1 12.7 12.5 07/27/2006 05:50:00 4.4 1 6.1 2.6 4.4 1 6.5 2.3 3.5 0.7 5.7 1.9 295 6 291 165 12.5 0 12.7 12.2 07/27/2006 06:00:00 4.7 0.7 6.5 3 4.7 0.7 6.5 3.4 3.9 0.8 6.1 2.3 293 6 282 165 12.7 0 12.7 12.5 07/27/2006 06:10:00 5 0.6 6.1 3 5 0.6 6.1 3 4.3 0.8 6.1 2.3 292 6 288 165 12.8 0 13 12.5 07/27/2006 06:20:00 4.6 0.6 6.1 3.4 4.6 0.6 6.1 3 3.8 0.7 6.1 2.3 295 7 290 165 12.9 0 13.3 12.5 07/27/2006 06:30:00 4 0.8 5.7 1.9 4.1 0.8 5.7 1.9 3.6 0.9 5.7 1.5 291 8 297 165 13.1 0 13.3 12.7 07/27/2006 06:40:00 4.3 0.5 5.7 3 4.4 0.5 5.7 3 4 0.8 5.7 2.3 293 6 290 165 13.3 0 13.3 13 07/27/2006 06:50:00 4 0.5 5.7 3 4 0.5 5.7 2.6 3.9 0.7 5.7 1.9 291 6 287 165 13.6 0 13.8 13.3 07/27/2006 07:00:00 2.6 0.7 4.2 1.1 2.7 0.7 4.2 1.5 2.5 0.7 4.6 1.1 300 7 295 165 13.8 0 14.1 13.8 07/27/2006 07:10:00 1.2 0.6 2.6 0.4 1.2 0.7 3 0.4 1.3 0.6 2.6 0.4 308 5 298 165 14.2 0 14.6 14.1 07/27/2006 07:20:00 1 0.6 2.3 0.4 1 0.7 2.6 0.4 1.3 0.8 2.6 0.4 293 8 293 165 14.8 0.1 15.2 14.6 07/27/2006 07:30:00 1.8 0.6 3.8 0.4 2 0.6 3.8 0.7 2.2 0.4 3.4 1.1 281 8 296 165 14.6 0 14.9 14.6 07/27/2006 07:40:00 2.7 0.5 4.2 1.5 3 0.4 4.2 1.9 2.8 0.5 4.2 1.5 284 7 293 165 15 0.1 15.5 14.9 07/27/2006 07:50:00 2.4 0.6 3.8 0.4 2.7 0.5 3.8 1.1 2.2 0.5 3.8 0.7 293 9 296 165 15.4 0 16 15.2 07/27/2006 08:00:00 0.9 0.5 2.3 0.4 1.4 0.6 3 0.4 1.2 0.6 2.6 0.4 272 17 292 165 15.7 0 16.3 15.7 07/27/2006 08:10:00 2.1 0.6 3.4 0.7 2.5 0.5 3.8 1.5 2.2 0.5 3.8 0.7 284 19 278 165 15.5 0 16 15.5 07/27/2006 08:20:00 1.1 0.7 2.6 0.4 1.5 0.8 3 0.4 1.3 0.7 3 0.4 283 17 313 165 15.9 0.2 16.8 15.7 07/27/2006 08:30:00 1.2 0.8 3.8 0.4 1.6 0.8 3.8 0.4 1.5 0.9 4.2 0.4 233 26 234 165 15.9 0.3 16.8 15.7 07/27/2006 08:40:00 1.1 0.7 3 0.4 1.5 0.8 3.8 0.4 1.5 0.8 3.8 0.4 214 58 238 165 15.7 0 16.6 15.5 07/27/2006 08:50:00 1.2 0.7 3 0.4 1.8 0.7 3.4 0.4 1.6 0.6 3 0.4 254 61 190 165 15.9 0 16.6 15.7 07/27/2006 09:00:00 1.7 0.6 3.4 0.4 2.7 0.5 3.8 0.4 2.4 0.6 3.8 0.4 260 11 219 165 16.1 0 16.3 16 07/27/2006 09:10:00 2.3 0.7 5.3 0.7 2.9 0.6 5.3 1.5 2.7 0.6 4.6 1.1 235 24 187 165 16.1 0 16.3 16 07/27/2006 09:20:00 2.3 0.6 3.8 0.7 2.7 0.6 4.2 1.5 2.7 0.6 4.2 1.5 208 17 214 165 16.1 0 16.6 16.3 07/27/2006 09:30:00 1.5 0.9 3.8 0.4 1.8 1 4.2 0.4 1.9 0.8 3.4 0.4 190 35 184 165 16.4 0.1 16.8 16 07/27/2006 09:40:00 1.9 0.6 3 0.4 2.1 0.5 3.4 0.4 2.1 0.6 3.4 0.7 164 13 149 165 16.4 0.1 16.8 16 07/27/2006 09:50:00 1.8 0.7 3.4 0.4 2.1 0.6 3.8 0.4 2.4 0.5 3.8 0.7 153 17 158 165 16.2 0.1 16.8 16 07/27/2006 10:00:00 1.8 0.8 4.2 0.4 2.2 0.7 4.2 0.4 2.4 0.6 4.2 0.7 148 16 138 165 16.1 0 16.3 15.7 07/27/2006 10:10:00 2 0.8 3.8 0.4 2.4 0.7 4.2 0.7 2.5 0.7 4.2 1.1 156 15 154 165 16.3 0 16.6 16 07/27/2006 10:20:00 2.2 0.7 4.2 0.4 2.6 0.7 4.2 0.4 2.8 0.6 4.2 0.7 149 17 143 165 16.5 0 16.8 16.3 07/27/2006 10:30:00 2.8 0.5 4.2 1.5 3 0.5 4.6 1.9 3.2 0.5 4.2 1.9 150 11 165 165 16.6 0.2 17.1 16.3 07/27/2006 10:40:00 2.5 0.7 4.6 0.7 2.8 0.6 4.9 1.5 2.9 0.6 4.6 1.5 146 15 150 165 16.3 0.1 16.6 16 07/27/2006 10:50:00 2.4 0.7 4.2 0.4 2.7 0.7 4.6 1.1 2.7 0.6 4.2 1.1 141 17 129 165 16.6 0.2 17.1 16.3 07/27/2006 11:00:00 2.5 0.6 4.2 0.7 2.8 0.6 4.6 1.5 3 0.6 4.6 1.9 140 13 147 165 17 0.2 17.4 16.8 07/27/2006 11:10:00 2.1 0.5 4.2 0.7 2.5 0.5 4.2 1.1 2.5 0.7 4.6 0.4 135 13 147 165 16.8 0 16.8 16.6 07/27/2006 11:20:00 2.4 0.7 3.8 0.4 2.7 0.6 4.6 1.1 2.7 0.7 4.6 1.1 151 16 152 165 16.8 0 17.1 16.6 07/27/2006 11:30:00 2.8 0.7 4.9 1.5 3 0.6 5.3 1.5 2.9 0.7 5.3 1.5 145 15 152 165 16.8 0 17.1 16.3 07/27/2006 11:40:00 2.6 0.7 4.2 1.1 2.8 0.6 4.6 1.5 2.9 0.6 4.6 1.1 141 13 134 165 17 0.1 17.4 16.8 07/27/2006 11:50:00 2.3 0.6 4.2 0.4 2.6 0.5 4.2 1.1 2.9 0.5 4.2 1.5 148 15 145 165 17 0 17.4 16.8 07/27/2006 12:00:00 2.4 0.6 3.8 0.4 2.6 0.5 4.2 1.1 2.7 0.5 4.2 1.1 144 10 148 165 16.8 0 17.1 16.6 07/27/2006 12:10:00 3 0.6 4.9 1.5 3.2 0.5 4.9 1.9 3.3 0.5 4.9 1.9 145 11 140 165 17 0.1 17.4 16.8 07/27/2006 12:20:00 2.7 0.5 4.2 1.5 2.9 0.5 4.6 1.9 2.9 0.5 4.6 1.5 140 12 161 165 16.6 0 16.8 16.3 07/27/2006 12:30:00 2.8 0.5 3.8 1.5 3 0.5 4.6 1.9 3.1 0.6 4.6 0.7 141 19 116 165 16.6 0 16.8 16.3 07/27/2006 12:40:00 2.7 0.8 4.6 0.4 3 0.7 4.9 1.1 2.9 0.8 4.9 0.7 140 17 161 165 16.7 0 16.8 16 07/27/2006 12:50:00 2.5 0.6 4.2 1.1 2.8 0.5 4.6 1.5 2.8 0.5 4.6 1.9 139 13 137 165 17 0.2 17.4 16.6 07/27/2006 13:00:00 2.7 0.6 4.6 1.1 3 0.6 4.9 1.5 3 0.6 4.9 1.5 133 17 145 165 17 0 17.1 16.8 07/27/2006 13:10:00 3.1 0.6 4.9 1.5 3.3 0.5 4.9 1.9 3.3 0.5 4.9 1.9 124 13 130 165 17 0.2 17.7 16.8 07/27/2006 13:20:00 2.6 0.7 4.6 0.7 2.9 0.6 4.6 1.5 2.9 0.6 4.6 1.1 123 17 118 165 17.5 0 17.7 17.1 07/27/2006 13:30:00 2.4 0.8 4.9 0.4 2.8 0.7 5.3 0.7 2.7 0.7 4.2 0.4 121 19 135 165 17.5 0.2 17.7 16.8 07/27/2006 13:40:00 2.2 0.7 4.9 0.4 2.5 0.7 4.6 0.4 2.7 0.6 4.2 1.5 131 21 151 165 17.7 0.3 18.2 16.8 07/27/2006 13:50:00 2.5 0.6 4.2 0.7 2.7 0.6 4.6 1.1 2.8 0.6 4.2 1.5 124 15 135 165 18 0.2 18.5 17.7 07/27/2006 14:00:00 2.2 0.8 3.8 0.4 2.6 0.7 4.2 0.7 2.7 0.6 4.2 0.7 123 19 115 165 17.9 0.1 18.2 17.1 07/27/2006 14:10:00 2.3 1 4.2 0.4 2.5 0.8 4.6 0.7 2.7 0.7 4.6 1.1 147 15 115 165 18 0 18.2 17.7 07/27/2006 14:20:00 2.3 0.7 4.6 0.7 2.6 0.7 4.6 1.1 2.6 0.6 4.6 1.1 127 14 128 165 17.9 0 18.2 17.7 07/27/2006 14:30:00 2.5 0.7 4.6 0.4 2.8 0.6 4.9 1.1 2.8 0.7 4.9 1.1 134 15 128 165 18.1 0 18.2 17.7 07/27/2006 14:40:00 2.3 0.8 3.8 0.4 2.6 0.7 3.8 0.7 2.7 0.7 4.2 0.4 144 17 166 165 18 0 18.2 17.7 07/27/2006 14:50:00 2.9 0.6 4.6 1.5 3.1 0.6 4.9 1.5 3.1 0.5 4.6 1.5 132 20 159 165 18 0 18.2 17.7 07/27/2006 15:00:00 2.5 0.6 4.2 1.1 2.8 0.6 4.6 1.5 2.8 0.7 4.6 1.5 138 14 157 165 17.8 0 18 17.4 07/27/2006 15:10:00 2.9 0.8 4.6 0.4 3.1 0.7 4.9 0.7 3 0.8 4.6 0.4 136 17 122 165 18.5 0.1 18.8 18 07/27/2006 15:20:00 2.7 0.6 4.2 0.4 3 0.5 4.2 0.7 2.9 0.6 4.2 1.1 142 13 143 165 18.2 0.1 18.5 17.7 07/27/2006 15:30:00 3 0.6 4.6 1.5 3.3 0.5 4.6 1.9 3.3 0.6 4.9 1.9 133 13 136 165 18.2 0 18.2 18 07/27/2006 15:40:00 2.8 0.5 4.6 1.5 3.1 0.5 4.6 1.9 3.1 0.5 4.6 1.5 131 11 123 165 18.1 0 18.2 18 07/27/2006 15:50:00 2.5 0.7 4.2 0.7 2.8 0.6 4.6 1.5 3 0.6 4.6 1.9 139 17 165 165 18 0 18.2 17.4 07/27/2006 16:00:00 3 0.6 4.6 1.5 3.2 0.6 4.6 1.9 3.3 0.5 4.6 1.9 134 10 121 165 18.2 0.1 18.5 18 07/27/2006 16:10:00 3.1 0.6 4.6 1.5 3.3 0.5 4.9 1.9 3.4 0.6 4.9 1.9 134 8 135 165 18.1 0.2 18.5 17.7 07/27/2006 16:20:00 2.4 0.6 4.2 0.7 2.7 0.5 4.2 1.5 2.8 0.5 4.2 1.5 140 11 136 165 17.9 0 18 17.7 07/27/2006 16:30:00 2.6 0.5 4.2 1.1 2.9 0.4 4.2 1.5 2.9 0.4 4.2 1.9 138 11 117 165 18.1 0 18.5 17.7 07/27/2006 16:40:00 2.1 0.6 3.4 0.4 2.4 0.5 3.8 1.1 2.5 0.5 3.8 0.7 138 13 128 165 17.9 0 18.2 17.7 07/27/2006 16:50:00 2.2 0.5 3.8 1.1 2.5 0.5 3.8 1.5 2.6 0.4 3.8 1.9 134 9 142 165 17.8 0 18 17.7 07/27/2006 17:00:00 1.8 0.6 3.4 0.4 2.2 0.5 3.4 1.1 2.2 0.6 3.8 0.4 135 14 136 165 18 0 18.2 17.7 07/27/2006 17:10:00 1.9 0.5 3 0.7 2.3 0.4 3.4 1.5 2.4 0.5 3.4 1.1 120 10 123 165 17.9 0 18 17.7 07/27/2006 17:20:00 1.6 0.7 3 0.4 2.1 0.6 3.4 0.7 2.1 0.5 3.4 1.1 137 18 127 165 18 0 18.2 17.7 07/27/2006 17:30:00 1 0.5 2.3 0.4 1.5 0.5 2.6 0.4 1.5 0.5 2.6 0.4 130 23 125 165 18.3 0 18.5 18.2 07/27/2006 17:40:00 0.8 0.4 1.9 0.4 1.3 0.5 2.3 0.4 1.4 0.4 2.6 0.4 126 19 117 165 18.4 0 18.5 18 07/27/2006 17:50:00 0.5 0.3 1.5 0.4 0.9 0.5 1.9 0.4 1 0.5 2.3 0.4 140 38 111 165 18.2 0.1 18.5 18 07/27/2006 18:00:00 0.4 0.2 1.5 0.4 0.9 0.4 1.9 0.4 1 0.3 1.9 0.4 176 9 167 165 18 0 18.2 18 07/27/2006 18:10:00 0.6 0.4 1.9 0.4 1 0.4 2.3 0.4 1.1 0.5 2.3 0.4 176 12 179 165 17.6 0 18 17.4 07/27/2006 18:20:00 0.6 0.3 1.5 0.4 1.2 0.2 1.9 0.7 1.3 0.3 1.9 0.4 156 8 165 165 17.5 0.1 17.7 17.1 07/27/2006 18:30:00 0.5 0.3 1.1 0.4 1.1 0.3 1.9 0.4 1.2 0.3 1.9 0.4 146 10 135 165 17.7 0 17.7 17.4 07/27/2006 18:40:00 0.6 0.3 1.5 0.4 1.2 0.3 1.9 0.4 1.3 0.3 1.9 0.7 151 7 145 165 17.4 0 17.7 17.1 07/27/2006 18:50:00 0.8 0.4 1.9 0.4 1.3 0.4 2.3 0.7 1.3 0.4 2.3 0.4 162 24 142 165 17.2 0 17.4 16.8 07/27/2006 19:00:00 0.7 0.3 1.5 0.4 1.1 0.4 1.9 0.4 1 0.3 1.5 0.4 183 17 165 165 16.8 0 17.1 16.8 07/27/2006 19:10:00 1.1 0.6 2.6 0.4 1.5 0.7 3 0.4 1.3 0.7 2.6 0.4 227 14 221 165 16.7 0.1 16.8 16.3 07/27/2006 19:20:00 0.7 0.4 1.9 0.4 1.2 0.5 2.3 0.4 1.1 0.5 2.3 0.4 253 12 222 165 16.5 0 17.1 16.3 07/27/2006 19:30:00 2.5 0.8 4.6 0.7 2.8 0.7 4.6 1.5 2.5 0.8 4.6 0.7 279 14 284 165 16.5 0.2 17.1 16.3 07/27/2006 19:40:00 3.9 0.3 4.6 3 4.1 0.3 4.9 3 3.8 0.4 4.9 2.6 290 5 286 165 16.6 0 16.8 16.3 07/27/2006 19:50:00 4.4 0.4 5.3 3.4 4.5 0.4 5.7 3.4 3.9 0.6 5.7 2.6 292 4 289 165 15.9 0.2 16.6 15.5 07/27/2006 20:00:00 4.5 0.4 5.7 3.8 4.6 0.4 5.7 3.8 3.6 0.5 4.6 1.9 297 2 298 165 15.5 0 15.7 15.2 07/27/2006 20:10:00 4.9 0.3 5.7 4.2 5 0.3 5.7 4.2 4 0.5 5.3 3 295 3 293 165 15.2 0 15.7 15.2 07/27/2006 20:20:00 4.6 0.3 5.3 3.8 4.7 0.3 5.3 4.2 3.6 0.5 4.9 2.6 299 4 299 165 14.8 0.1 15.2 14.6 07/27/2006 20:30:00 4.5 0.4 5.3 3.4 4.7 0.4 5.7 3.8 3.4 0.5 4.6 2.3 300 3 302 165 14.5 0 14.9 14.4 07/27/2006 20:40:00 4.9 0.4 5.7 3.8 5.1 0.4 5.7 3.8 4 0.5 5.3 2.6 295 3 296 165 14.2 0.1 14.6 14.1 07/27/2006 20:50:00 4.2 0.5 5.3 3 4.5 0.5 5.7 3.4 3.4 0.6 5.3 2.3 296 4 292 165 14.1 0 14.4 14.1 07/27/2006 21:00:00 3.7 0.5 4.9 2.3 3.9 0.5 5.3 3 3.4 0.7 5.3 2.3 292 6 289 165 14.1 0 14.4 14.1 07/27/2006 21:10:00 4.7 0.5 5.7 3.8 4.9 0.5 5.7 3.8 4.8 0.6 6.1 3.4 287 4 287 165 14 0 14.4 13.8 07/27/2006 21:20:00 4.1 0.4 4.9 3.4 4.3 0.4 5.3 3.4 3.9 0.6 5.3 2.3 291 5 291 165 13.9 0 14.1 13.8 07/27/2006 21:30:00 3.5 0.4 4.6 2.3 3.7 0.4 4.6 2.6 3.4 0.6 4.6 1.9 291 3 290 165 13.9 0 14.1 13.8 07/27/2006 21:40:00 3.6 0.4 4.9 2.6 3.8 0.4 4.9 3 3.8 0.3 4.9 3 281 4 281 165 13.9 0 14.1 13.8 07/27/2006 21:50:00 3.4 0.4 4.6 2.6 3.7 0.4 4.6 2.6 3.5 0.6 4.9 1.9 287 5 285 165 13.8 0 13.8 13.5 07/27/2006 22:00:00 3.5 0.6 4.9 1.9 3.8 0.6 4.9 2.3 3.8 0.6 5.3 2.3 279 5 273 165 13.6 0.1 13.8 13.5 07/27/2006 22:10:00 3.7 0.4 4.6 2.6 3.9 0.4 4.6 3 3.9 0.3 4.6 3 276 3 278 165 13.5 0 13.8 13.5 07/27/2006 22:20:00 2.7 0.6 4.2 1.1 3.2 0.6 4.2 1.9 3.3 0.5 4.2 1.9 256 13 279 165 13.8 0 13.8 13.5 07/27/2006 22:30:00 2.2 0.4 3.4 1.1 2.7 0.4 3.8 1.9 3 0.5 4.2 2.3 258 12 264 165 13.8 0 14.1 13.5 07/27/2006 22:40:00 2.2 0.7 3.8 0.7 2.7 0.7 4.2 1.1 2.8 0.7 4.2 1.1 276 7 268 165 13.8 0 14.1 13.5 07/27/2006 22:50:00 2.2 0.4 3.4 1.1 2.7 0.3 3.4 1.9 3 0.4 3.8 1.9 260 10 268 165 14 0 14.1 13.8 07/27/2006 23:00:00 2.5 0.6 3.8 1.1 3.2 0.5 4.2 1.9 3.4 0.5 4.6 2.3 265 7 270 165 13.9 0 14.1 13.8 07/27/2006 23:10:00 4 0.6 5.3 2.3 4.3 0.5 5.3 3 4.2 0.6 5.7 2.6 279 4 277 165 13.5 0 13.8 13.5 07/27/2006 23:20:00 4.1 0.5 4.9 3 4.3 0.4 5.3 3.4 4.5 0.4 5.7 3.4 272 3 272 165 13.5 0 13.8 13.3 07/27/2006 23:30:00 3.5 0.6 4.6 2.3 3.6 0.6 4.9 2.3 3.6 0.8 4.9 1.5 285 3 271 165 13.7 0 14.4 13.5 07/27/2006 23:40:00 2.9 0.6 4.9 1.9 3.1 0.6 4.9 2.3 3 0.6 4.9 1.5 283 5 284 165 13.9 0 14.1 13.5 07/27/2006 23:50:00 4.1 0.5 4.9 3 4.3 0.5 5.3 3 4.1 0.6 5.7 2.6 289 5 280 165 13.5 0 13.8 13.3 07/28/2006 00:00:00 3 0.3 3.8 2.3 3.2 0.3 3.8 2.6 3.2 0.5 4.2 1.9 287 7 289 165 13.4 0 13.5 13 07/28/2006 00:10:00 2.5 0.6 3.8 1.5 2.7 0.6 4.2 1.5 2.6 0.8 4.2 0.7 282 9 276 165 13.7 0 13.8 13.5 07/28/2006 00:20:00 2.3 0.4 3 1.5 2.5 0.4 3.4 1.5 2 0.4 3 0.7 290 13 292 165 13.5 0.1 13.8 13.3 07/28/2006 00:30:00 2.5 0.4 3.8 1.9 2.6 0.4 3.8 1.9 2.2 0.4 3.8 1.5 301 8 302 165 13 0 13.3 13 07/28/2006 00:40:00 2.5 0.6 3.8 1.5 2.6 0.6 3.8 1.5 2.4 0.7 3.8 1.1 286 11 291 165 13.4 0 13.8 13 07/28/2006 00:50:00 1.9 0.4 3 0.4 2.2 0.4 3 0.7 2.2 0.3 3 1.1 261 10 258 165 13.9 0 14.1 13.5 07/28/2006 01:00:00 3 0.6 4.6 1.9 3.3 0.5 4.6 2.3 3.2 0.6 4.6 1.9 270 8 277 165 13.5 0.1 13.8 13.3 07/28/2006 01:10:00 1.8 0.7 3 0.4 1.8 0.8 3.4 0.4 1.6 0.7 3 0.4 267 28 283 165 13.3 0 13.3 13 07/28/2006 01:20:00 2.8 0.4 3.8 1.5 2.9 0.4 3.8 1.1 2.9 0.4 3.8 1.5 201 11 204 165 13.3 0 13.5 13.3 07/28/2006 01:30:00 2.2 0.4 3 1.5 2.3 0.4 3 1.5 2.5 0.4 3.4 1.5 230 12 228 165 13.1 0 13.3 13 07/28/2006 01:40:00 1.8 0.4 3 0.7 2 0.5 3 0.7 2.3 0.3 3.4 1.5 251 9 249 165 13 0.1 13.3 12.7 07/28/2006 01:50:00 2 0.7 3.8 0.7 2.2 0.7 4.2 0.7 2.4 0.6 4.2 1.1 236 20 218 165 13 0 13.3 12.7 07/28/2006 02:00:00 2.2 0.4 3.4 1.1 2.4 0.4 3.4 1.5 2.4 0.4 3.8 1.5 232 9 231 165 12.7 0 13 12.5 07/28/2006 02:10:00 2.2 0.9 4.2 0.4 2.6 0.9 4.2 0.4 3 0.9 4.6 0.7 258 12 265 165 12.5 0.1 12.7 11.9 07/28/2006 02:20:00 2.2 0.5 3.4 1.1 2.5 0.5 3.4 1.1 2.7 0.6 3.8 1.1 267 10 278 165 12.3 0 12.5 11.9 07/28/2006 02:30:00 1.2 0.5 2.6 0.4 1.5 0.5 2.6 0.4 1.4 0.5 2.3 0.4 216 19 192 165 12.5 0 12.7 11.9 07/28/2006 02:40:00 1.5 0.4 2.3 0.4 1.8 0.4 2.6 1.1 1.6 0.4 2.6 0.4 230 17 211 165 12.3 0 12.5 11.9 07/28/2006 02:50:00 1.8 0.4 2.6 0.7 2.2 0.4 3.4 1.1 2.4 0.3 3.4 1.9 249 9 271 165 12.2 0 12.5 11.9 07/28/2006 03:00:00 2.1 0.5 3.4 0.7 2.3 0.4 3.4 1.1 2.4 0.5 3.8 1.1 230 14 213 165 12.2 0.1 12.5 11.4 07/28/2006 03:10:00 1.8 0.4 2.6 0.4 2 0.4 3 0.4 2.2 0.4 3 0.7 221 12 217 165 11.8 0 12.2 11.7 07/28/2006 03:20:00 1.9 0.4 3 1.1 2 0.4 3 1.5 2.4 0.4 3.4 1.1 212 15 193 165 11.4 0.1 11.7 11.4 07/28/2006 03:30:00 2.8 0.4 3.8 1.5 2.9 0.3 3.4 1.9 3.2 0.4 4.2 2.3 189 8 194 165 11.5 0 11.9 11.1 07/28/2006 03:40:00 3.1 0.3 3.8 2.3 3.1 0.3 3.8 2.3 3.3 0.3 3.8 2.3 185 7 176 165 11.7 0 11.9 11.4 07/28/2006 03:50:00 2.9 0.2 3.4 2.3 2.9 0.2 3.4 2.3 3.2 0.2 3.8 2.6 186 6 183 165 11.3 0 11.7 11.1 07/28/2006 04:00:00 2.6 0.4 3.4 1.5 2.5 0.4 3.4 1.5 2.8 0.4 3.8 1.9 178 8 178 165 11.2 0 11.4 11.1 07/28/2006 04:10:00 2.4 0.4 3.4 1.5 2.4 0.4 3.4 1.5 2.7 0.3 3.4 1.9 182 8 186 165 11.3 0 11.4 11.1 07/28/2006 04:20:00 2.1 0.3 3 1.5 2.1 0.3 3 1.5 2.3 0.3 3 1.5 171 6 164 165 11.3 0 11.4 11.1 07/28/2006 04:30:00 1.8 0.6 3 0.4 1.9 0.6 3 0.4 2.1 0.5 3.4 1.1 172 7 170 165 11.1 0 11.4 10.9 07/28/2006 04:40:00 1.2 0.5 2.3 0.4 1.3 0.5 2.3 0.4 1.6 0.5 2.6 0.4 170 5 164 165 11.1 0 11.4 10.9 07/28/2006 04:50:00 1.1 0.4 1.9 0.4 1.2 0.4 1.9 0.4 1.5 0.3 1.9 0.7 170 6 175 165 11.1 0 11.4 11.1 07/28/2006 05:00:00 1.2 0.4 1.9 0.4 1.3 0.4 2.3 0.4 1.6 0.2 2.3 1.1 162 5 153 165 11 0 11.4 10.9 07/28/2006 05:10:00 1.5 0.3 2.3 0.4 1.5 0.3 2.3 0.7 1.6 0.2 2.3 1.1 177 10 164 165 11.1 0 11.4 10.9 07/28/2006 05:20:00 1.4 0.4 2.3 0.7 1.5 0.4 2.3 0.7 1.8 0.3 2.6 1.1 183 7 187 165 11.3 0 11.4 11.1 07/28/2006 05:30:00 1.2 0.6 2.6 0.4 1.2 0.6 2.6 0.4 1.7 0.4 2.6 0.7 166 3 161 165 11.4 0 11.7 11.1 07/28/2006 05:40:00 2.7 0.3 3.4 1.9 2.7 0.3 3.4 1.9 2.8 0.4 3.8 1.9 161 3 164 165 11.5 0 11.7 11.1 07/28/2006 05:50:00 2.2 0.3 2.6 1.5 2.2 0.3 2.6 1.5 2.2 0.2 2.6 1.9 166 9 162 165 11.7 0 11.9 11.7 07/28/2006 06:00:00 1.9 0.2 2.6 1.5 2 0.2 2.6 1.5 2 0.2 2.6 1.5 167 4 165 165 11.8 0 11.9 11.7 07/28/2006 06:10:00 2 0.3 2.6 1.5 2 0.3 2.6 1.1 1.9 0.3 2.6 1.1 162 4 165 165 11.9 0 12.2 11.4 07/28/2006 06:20:00 1.8 0.3 2.6 1.1 1.8 0.3 2.6 1.1 1.9 0.3 2.6 1.1 152 7 151 165 12.1 0 12.2 11.9 07/28/2006 06:30:00 2.5 0.4 3.4 1.5 2.5 0.4 3.4 1.5 2.5 0.4 3.4 1.9 158 4 156 165 12.3 0 12.5 12.2 07/28/2006 06:40:00 2.9 0.4 3.8 1.9 2.8 0.4 3.8 1.9 2.9 0.4 3.8 1.9 159 3 154 165 12.2 0 12.5 12.2 07/28/2006 06:50:00 2.8 0.3 3.4 1.9 2.7 0.3 3.4 1.9 2.9 0.3 3.8 2.3 155 5 159 165 12.3 0 12.5 12.2 07/28/2006 07:00:00 2.4 0.4 3.4 1.5 2.4 0.4 3 1.5 2.6 0.4 4.2 1.9 150 5 158 165 12.3 0 12.5 12.2 07/28/2006 07:10:00 2.2 0.3 3 1.5 2.2 0.4 3 1.5 2.4 0.4 3.4 1.5 150 9 142 165 12.4 0 12.7 12.2 07/28/2006 07:20:00 2.3 0.4 3.4 1.5 2.4 0.4 3.4 1.5 2.6 0.4 3.4 1.9 140 8 143 165 12.7 0 13 12.5 07/28/2006 07:30:00 2.5 0.5 3.8 1.5 2.5 0.4 3.8 1.5 2.7 0.5 4.2 1.9 142 8 129 165 12.7 0 12.7 12.7 07/28/2006 07:40:00 3.2 0.4 4.2 2.3 3.2 0.4 4.2 2.3 3.3 0.4 4.6 2.3 139 8 141 165 12.7 0 13 12.5 07/28/2006 07:50:00 4.3 0.6 5.7 3 4.4 0.6 5.7 3 4.4 0.6 6.1 3 133 6 129 165 12.9 0 13 12.7 07/28/2006 08:00:00 4.5 0.5 5.7 3 4.5 0.5 5.7 3 4.7 0.5 6.1 3.4 143 9 135 165 12.9 0.1 13.3 12.5 07/28/2006 08:10:00 4.6 0.6 6.1 2.6 4.6 0.5 5.7 2.6 4.8 0.5 6.1 3.4 161 9 162 165 13.1 0.2 13.5 12.7 07/28/2006 08:20:00 3.7 0.8 5.3 1.9 3.8 0.7 5.3 1.9 4 0.8 5.7 1.9 156 10 164 165 13.1 0.1 13.5 13 07/28/2006 08:30:00 2.9 0.6 4.6 1.1 3.2 0.6 4.6 1.9 3.4 0.5 4.9 2.3 154 14 149 165 13.6 0.1 13.8 13.3 07/28/2006 08:40:00 2.8 0.5 4.2 1.5 3 0.5 4.6 1.9 3.1 0.4 4.6 2.3 155 9 143 165 13.8 0 14.4 13.5 07/28/2006 08:50:00 1.7 0.6 3.4 0.4 2.2 0.5 3.4 1.1 2.5 0.5 3.8 1.5 151 13 181 165 13.8 0.1 14.1 13.5 07/28/2006 09:00:00 1.2 0.8 3 0.4 1.6 0.8 3.4 0.4 1.9 0.8 3.4 0.4 148 15 148 165 14.2 0.3 14.9 13.8 07/28/2006 09:10:00 0.6 0.4 1.9 0.4 0.8 0.5 2.3 0.4 1.3 0.5 2.6 0.4 122 26 152 165 14.2 0 14.9 14.1 07/28/2006 09:20:00 0.5 0.3 1.5 0.4 0.7 0.5 1.9 0.4 0.7 0.4 1.9 0.4 20 66 322 165 15 0.5 16.3 14.4 07/28/2006 09:30:00 0.4 0.2 1.5 0.4 0.5 0.2 1.5 0.4 0.4 0.2 1.1 0.4 336 27 348 165 16.5 0.1 16.8 16.3 07/28/2006 09:40:00 0.5 0.4 1.9 0.4 0.6 0.4 1.9 0.4 0.9 0.5 2.3 0.4 63 47 72 165 15.8 0.2 16.3 15.5 07/28/2006 09:50:00 0.8 0.5 2.6 0.4 0.9 0.5 2.6 0.4 1.1 0.5 2.3 0.4 60 49 123 165 16.8 0.4 17.7 16.3 07/28/2006 10:00:00 1.7 0.8 3.4 0.4 1.7 0.7 3.4 0.4 1.8 0.6 3.4 0.4 18 27 18 165 18 0 18.2 17.4 07/28/2006 10:10:00 0.7 0.5 2.6 0.4 0.8 0.5 2.6 0.4 1 0.6 2.6 0.4 81 43 37 165 17.8 0 18 17.4 07/28/2006 10:20:00 0.9 0.6 3.4 0.4 0.8 0.6 3 0.4 0.9 0.8 3.8 0.4 2 76 1 165 18.5 0.2 18.8 18 07/28/2006 10:30:00 1.2 0.6 2.6 0.4 1.2 0.5 2.6 0.4 1.2 0.6 2.6 0.4 348 90 334 165 18.6 0.2 19.1 18.2 07/28/2006 10:40:00 1 0.7 3.4 0.4 1.1 0.7 3.4 0.4 1 0.7 3.4 0.4 358 69 10 165 19.2 0 19.7 19.1 07/28/2006 10:50:00 1.2 0.5 2.6 0.4 1.5 0.5 2.6 0.4 1.5 0.5 2.6 0.4 80 26 118 165 18.2 0.3 19.1 17.7 07/28/2006 11:00:00 1.7 0.5 3 0.4 1.6 0.5 3 0.4 1.7 0.5 3 0.4 16 21 36 165 17.9 0.1 18.5 17.4 07/28/2006 11:10:00 1.2 0.6 2.3 0.4 1.3 0.6 2.6 0.4 1.3 0.6 2.3 0.4 10 49 349 165 18.8 0.2 19.4 18.5 07/28/2006 11:20:00 1.5 0.7 4.2 0.4 1.6 0.7 4.9 0.4 1.3 0.8 4.2 0.4 350 61 286 165 18.4 0.4 19.4 17.7 07/28/2006 11:30:00 1 0.5 2.3 0.4 1.1 0.5 2.6 0.4 1.2 0.5 2.6 0.4 323 41 217 165 18.5 0.5 19.4 17.7 07/28/2006 11:40:00 1.3 0.8 3.4 0.4 1.3 0.7 3 0.4 1.3 0.6 2.6 0.4 329 64 7 165 19.5 0 20.2 19.1 07/28/2006 11:50:00 1.5 0.8 3.4 0.4 1.4 0.7 3.4 0.4 1.5 0.7 3 0.4 10 53 345 165 19 0.2 20 18.5 07/28/2006 12:00:00 1.2 0.8 3.4 0.4 1.2 0.9 3.8 0.4 1.5 0.9 3.8 0.4 186 86 209 165 19.3 0 20 18.8 07/28/2006 12:10:00 1.2 0.7 3 0.4 1.2 0.7 3 0.4 1.3 0.6 3 0.4 151 58 166 165 19.5 0.2 20.2 18.8 07/28/2006 12:20:00 1 0.6 3.4 0.4 1 0.6 3.4 0.4 1.1 0.6 2.6 0.4 153 66 102 165 19.7 0.1 20 19.7 07/28/2006 12:30:00 1.5 0.6 3 0.4 1.4 0.6 3 0.4 1.4 0.5 2.6 0.4 11 24 26 165 19.1 0.2 19.7 18.5 07/28/2006 12:40:00 1 0.5 2.3 0.4 0.9 0.5 1.9 0.4 1 0.5 2.3 0.4 10 33 354 165 19.1 0.3 19.7 18.5 07/28/2006 12:50:00 0.9 0.5 2.3 0.4 0.9 0.5 2.3 0.4 1 0.6 2.6 0.4 174 64 160 165 19.7 0.1 20 19.7 07/28/2006 13:00:00 1 0.6 3 0.4 1 0.6 3.4 0.4 1.1 0.6 3 0.4 346 82 145 165 19.7 0 20 19.7 07/28/2006 13:10:00 1.8 0.6 3.4 0.4 1.6 0.6 3 0.4 1.9 0.6 3.4 0.4 6 86 327 165 19.4 0.2 20 18.8 07/28/2006 13:20:00 1.3 0.8 3.4 0.4 1.2 0.8 3.4 0.4 1.4 0.8 3.4 0.4 119 51 165 165 19.2 0 19.4 19.1 07/28/2006 13:30:00 1.2 0.8 3.4 0.4 1.1 0.8 3.4 0.4 1.3 0.8 3.4 0.4 92 79 151 165 19 0.2 19.4 18.5 07/28/2006 13:40:00 1.2 0.5 2.3 0.4 1 0.5 2.3 0.4 1.2 0.5 2.3 0.4 9 22 10 165 19.8 0.2 20.5 19.4 07/28/2006 13:50:00 1.7 0.7 3.4 0.4 1.4 0.6 3 0.4 1.6 0.7 3 0.4 356 15 334 165 20.2 0 20.5 20 07/28/2006 14:00:00 0.9 0.6 2.6 0.4 0.8 0.6 2.3 0.4 0.9 0.6 2.6 0.4 27 79 353 165 20.1 0 20.5 20 07/28/2006 14:10:00 0.5 0.3 1.9 0.4 0.4 0.2 1.5 0.4 0.5 0.3 1.5 0.4 338 69 3 165 19.8 0 20.2 19.7 07/28/2006 14:20:00 0.6 0.4 2.3 0.4 0.5 0.3 1.9 0.4 0.6 0.4 1.9 0.4 36 66 342 165 19.7 0 20 19.7 07/28/2006 14:30:00 1.4 0.7 2.6 0.4 1.1 0.6 2.3 0.4 1.5 0.9 3 0.4 11 41 322 165 20 0 20.2 19.7 07/28/2006 14:40:00 1.1 0.5 2.6 0.4 0.8 0.5 2.3 0.4 1.2 0.6 2.6 0.4 0 13 350 165 19.5 0 19.7 19.4 07/28/2006 14:50:00 0.7 0.4 1.9 0.4 0.6 0.3 1.5 0.4 0.7 0.4 1.9 0.4 28 49 8 165 19.3 0 19.7 19.1 07/28/2006 15:00:00 0.7 0.4 2.3 0.4 0.6 0.4 1.9 0.4 0.7 0.5 2.3 0.4 9 39 325 165 19.5 0 19.7 19.4 07/28/2006 15:10:00 0.6 0.4 2.3 0.4 0.5 0.3 2.3 0.4 0.7 0.4 2.3 0.4 78 66 60 165 19.3 0.2 19.7 18.8 07/28/2006 15:20:00 0.5 0.3 1.9 0.4 0.4 0.2 1.5 0.4 0.4 0.2 1.1 0.4 3 94 310 165 19.2 0.2 19.7 18.5 07/28/2006 15:30:00 0.8 0.5 2.3 0.4 0.6 0.4 1.9 0.4 0.6 0.4 2.3 0.4 352 32 2 165 19.3 0 19.7 19.1 07/28/2006 15:40:00 1.2 0.6 2.6 0.4 0.9 0.5 2.6 0.4 1.1 0.6 2.3 0.4 4 14 347 165 19.4 0 19.7 19.1 07/28/2006 15:50:00 1.1 0.5 2.3 0.4 0.9 0.5 1.9 0.4 0.9 0.5 2.6 0.4 358 23 16 165 19.7 0 20 19.7 07/28/2006 16:00:00 0.6 0.3 1.5 0.4 0.4 0.2 1.5 0.4 0.5 0.3 1.5 0.4 14 29 7 165 19 0.2 19.7 18.5 07/28/2006 16:10:00 0.5 0.3 1.5 0.4 0.4 0.2 1.1 0.4 0.6 0.3 1.9 0.4 114 18 105 165 18.3 0 19.1 18 07/28/2006 16:20:00 1.6 0.5 2.6 0.4 1.5 0.5 2.6 0.4 1.8 0.4 2.6 0.4 123 9 111 165 18.2 0.2 18.5 18 07/28/2006 16:30:00 1.6 0.6 3 0.4 1.6 0.6 3 0.4 1.8 0.5 2.6 0.4 117 12 123 165 18.4 0 18.5 18 07/28/2006 16:40:00 0.8 0.5 2.3 0.4 0.6 0.4 1.9 0.4 0.8 0.5 1.9 0.4 30 49 339 165 18.6 0.3 19.4 18 07/28/2006 16:50:00 1.2 0.5 2.3 0.4 0.9 0.5 2.3 0.4 1.2 0.5 2.3 0.4 11 13 359 165 19 0.3 19.7 18.2 07/28/2006 17:00:00 2.2 0.3 2.6 1.1 1.7 0.4 2.6 0.7 2.3 0.4 3 1.1 10 6 0 165 18.5 0.1 18.5 17.7 07/28/2006 17:10:00 2 0.4 3 1.1 1.8 0.4 3 0.4 2.1 0.5 3 0.7 20 9 22 165 18.6 0.1 19.1 18.2 07/28/2006 17:20:00 2 0.5 3 0.7 1.9 0.5 3 0.4 1.9 0.5 3 0.7 27 12 16 165 18.5 0.2 19.1 18 07/28/2006 17:30:00 1.5 0.4 2.3 0.4 1.3 0.4 2.3 0.4 1.5 0.4 2.6 0.4 22 13 3 165 18.5 0.1 19.1 18 07/28/2006 17:40:00 0.8 0.5 2.3 0.4 0.7 0.5 2.3 0.4 0.7 0.5 2.6 0.4 12 79 29 165 19.7 0.3 20.2 18.8 07/28/2006 17:50:00 0.8 0.4 1.9 0.4 0.8 0.4 1.5 0.4 0.9 0.4 1.9 0.4 104 13 109 165 19.2 0.2 19.7 18.5 07/28/2006 18:00:00 0.7 0.5 1.9 0.4 0.6 0.4 2.3 0.4 0.7 0.5 3 0.4 230 94 331 165 19.2 0 19.7 19.1 07/28/2006 18:10:00 1.1 0.4 1.9 0.4 0.8 0.5 1.9 0.4 1.2 0.5 2.3 0.4 332 15 336 165 19.5 0.1 19.7 19.1 07/28/2006 18:20:00 1.9 0.4 3 0.7 1.8 0.5 3 0.4 2 0.4 3 0.7 341 11 357 165 19.4 0 19.7 19.1 07/28/2006 18:30:00 2.4 0.5 3.8 1.1 2.2 0.8 3.8 0.4 2.4 0.5 3.4 1.5 346 8 336 165 19 0.3 19.7 18.5 07/28/2006 18:40:00 2.1 0.3 2.6 1.1 2.1 0.4 2.6 0.7 2.3 0.2 2.6 1.5 344 7 343 165 17.9 0.3 18.5 17.4 07/28/2006 18:50:00 1.9 0.5 2.6 1.1 2 0.5 2.6 1.1 1.9 0.4 2.6 1.1 326 7 330 165 17 0.2 17.4 16.8 07/28/2006 19:00:00 1.3 0.4 2.3 0.4 1.2 0.4 2.3 0.4 1.3 0.3 2.3 0.7 337 13 315 165 16.8 0.1 17.4 16.8 07/28/2006 19:10:00 1.7 0.3 2.3 1.1 1.8 0.3 2.6 1.1 1.7 0.4 2.3 0.4 316 9 318 165 16.4 0.3 17.4 16.3 07/28/2006 19:20:00 1.8 0.3 2.3 1.1 2 0.2 2.6 1.5 1.7 0.3 2.6 0.7 315 13 308 165 16.7 0.1 16.8 16.3 07/28/2006 19:30:00 2.8 0.4 3.4 1.9 2.5 0.5 3.4 1.1 2.8 0.4 3.4 1.9 347 8 338 165 15.9 0.4 16.8 15.2 07/28/2006 19:40:00 2.8 0.2 3.4 2.3 2.8 0.3 3.4 1.5 2.8 0.2 3.4 2.3 338 11 359 165 14.8 0.2 15.5 14.6 07/28/2006 19:50:00 3.1 0.3 3.8 1.9 3.1 0.3 3.8 1.9 3 0.3 3.4 2.3 321 9 302 165 14.4 0 14.9 14.1 07/28/2006 20:00:00 4.1 0.5 5.3 2.6 4.1 0.5 5.3 2.6 4 0.5 4.9 2.6 338 8 340 165 14.1 0 14.6 14.1 07/28/2006 20:10:00 4.4 0.6 5.7 3 4.4 0.6 6.1 3 4 0.4 5.3 3 326 15 333 165 14 0 14.4 13.8 07/28/2006 20:20:00 5.5 0.7 7.2 3.8 5.6 0.7 7.2 3.4 4.5 0.9 6.8 2.6 297 9 297 165 14.6 0.4 15.5 14.1 07/28/2006 20:30:00 6.7 0.9 8.4 3.8 6.8 0.9 8.4 4.2 5.6 1.1 8.8 3.4 293 7 287 165 15.8 0 16 15.5 07/28/2006 20:40:00 5.4 0.8 7.6 3 5.5 0.9 7.6 3 4.4 0.9 7.2 2.3 296 9 300 165 15.8 0.1 16.3 15.7 07/28/2006 20:50:00 5.6 0.7 7.2 3.8 5.8 0.7 7.6 3.8 4.9 0.9 7.6 3 288 7 290 165 15.5 0 15.7 15.5 07/28/2006 21:00:00 5.9 0.6 7.6 4.2 6.1 0.6 8 4.6 5.1 0.8 7.2 3.4 294 9 289 165 15.6 0 15.7 15.5 07/28/2006 21:10:00 6.8 1 9.1 4.6 6.9 0.9 8.8 4.6 5.3 0.7 7.2 3.4 298 4 307 165 15.7 0 16 15.5 07/28/2006 21:20:00 7.6 0.6 8.8 5.3 7.5 0.5 8.8 5.7 5.8 0.8 9.1 3.8 297 5 300 165 15.7 0 16 15.7 07/28/2006 21:30:00 5.7 1.7 9.1 1.9 5.7 1.7 9.1 2.3 4.5 1.5 8 1.5 304 12 305 165 15.7 0.1 16 15.5 07/28/2006 21:40:00 4.9 1.4 8 1.1 4.9 1.3 8 1.1 3.6 1.2 6.1 0.4 306 12 297 165 15.2 0 15.7 15.2 07/28/2006 21:50:00 7 1 9.1 4.2 7 1 8.8 4.2 5.4 1 8 3.4 303 9 300 165 15.2 0 15.2 15.2 07/28/2006 22:00:00 8.4 1.2 11.1 4.6 8.3 1.2 11.1 4.9 6.7 1.1 9.5 3 300 7 291 165 14.9 0 15.2 14.6 07/28/2006 22:10:00 8 1.3 11.1 4.9 8 1.2 10.7 5.3 6.6 1.3 10.3 3.8 305 9 313 165 14.6 0.1 14.9 14.6 07/28/2006 22:20:00 7.6 0.8 9.5 5.3 7.5 0.9 9.5 4.9 6.1 0.9 8.8 3.8 303 8 299 165 14.6 0 14.9 14.6 07/28/2006 22:30:00 7.9 0.7 9.1 6.1 7.8 0.8 9.5 6.1 6.3 1 9.5 3.4 293 5 294 165 14.5 0 14.6 14.4 07/28/2006 22:40:00 8 0.6 9.1 6.1 8 0.7 9.5 6.1 6.7 1 9.1 4.6 291 5 300 165 14.5 0 14.6 14.6 07/28/2006 22:50:00 8.3 0.6 9.5 6.1 8.3 0.6 9.9 6.8 6.9 0.9 9.1 4.2 291 4 293 165 14.3 0.1 14.6 14.1 07/28/2006 23:00:00 8.2 0.5 9.5 6.8 8.3 0.5 9.5 6.8 7.7 0.6 9.1 6.1 286 4 291 165 14.1 0 14.4 14.1 07/28/2006 23:10:00 7.6 0.7 9.5 6.1 7.7 0.7 9.5 6.1 7 1.1 9.5 4.6 287 5 288 165 14 0 14.4 13.8 07/28/2006 23:20:00 7.6 0.8 9.1 5.3 7.6 0.8 9.5 5.7 6.5 1 9.1 3.8 293 5 297 165 14.1 0 14.4 13.8 07/28/2006 23:30:00 7.4 0.8 9.5 5.3 7.4 0.8 9.5 5.3 6.8 1 9.5 4.2 288 5 290 165 14 0 14.1 13.8 07/28/2006 23:40:00 7.7 1 10.3 5.3 7.7 1 10.7 5.3 6.5 1.2 10.3 3.8 291 7 287 165 13.9 0 14.1 13.8 07/28/2006 23:50:00 7.9 0.9 9.9 5.7 7.9 0.9 10.3 5.7 6.4 1.2 10.3 4.2 295 6 284 165 14 0.1 14.4 13.8 07/29/2006 00:00:00 8.9 0.7 11.5 7.2 8.9 0.7 11.1 6.8 7.2 1 9.5 5.3 299 7 309 165 14 0 14.4 13.8 07/29/2006 00:10:00 8.3 1.5 11.8 4.6 8.3 1.5 11.8 4.9 6.8 1.4 10.7 4.2 302 7 305 165 13.7 0 14.1 13.5 07/29/2006 00:20:00 7.8 1 10.3 4.9 7.8 1 9.9 4.9 6.5 1.2 9.1 4.2 306 9 314 165 13.5 0 13.8 13.3 07/29/2006 00:30:00 9.3 1.1 13 6.5 9.4 1.1 12.2 6.1 7.6 1.1 11.1 4.6 304 6 307 165 13.5 0 13.5 13.3 07/29/2006 00:40:00 9.5 1 12.6 6.8 9.5 1 12.6 6.5 7.5 1 10.3 5.3 303 6 313 165 13.4 0 13.8 13.3 07/29/2006 00:50:00 11.4 1.1 14.5 8.8 11.4 1.1 14.5 8.4 8.5 1 11.1 6.1 303 5 302 165 13.3 0 13.5 13.3 07/29/2006 01:00:00 12.3 1 14.5 9.9 12.2 1 14.5 9.5 9.2 1 12.2 6.8 305 5 298 165 13.4 0 13.5 13.3 07/29/2006 01:10:00 10.4 1.1 13 7.6 10.3 1.1 12.6 7.6 8.6 1 11.1 6.1 307 5 310 165 13.5 0 13.5 13.3 07/29/2006 01:20:00 9.7 0.9 12.2 6.8 9.7 1 12.2 7.2 8 1.1 11.1 5.3 307 6 309 165 13.3 0 13.8 13 07/29/2006 01:30:00 8.7 0.9 11.1 6.5 8.7 1 11.1 6.1 6.9 1 10.3 4.6 305 5 297 165 13.4 0 13.5 13 07/29/2006 01:40:00 7.9 0.8 9.9 5.7 7.9 0.8 10.3 5.7 6.5 0.7 8.4 4.9 307 7 307 165 13.5 0 13.8 13.3 07/29/2006 01:50:00 9.2 1.2 12.2 6.5 9.2 1.2 12.6 6.5 8 1.2 11.5 5.3 309 7 307 165 12.9 0.1 13.3 12.7 07/29/2006 02:00:00 13.2 2.5 17.9 7.2 13.1 2.5 17.9 7.6 10.3 1.9 15.6 6.1 307 6 301 165 12.9 0 13 12.7 07/29/2006 02:10:00 13.3 1.5 16.8 9.1 13.2 1.5 16.4 10.3 11.3 1.9 15.3 6.8 310 6 314 165 12.7 0 13 12.5 07/29/2006 02:20:00 11.2 1.1 14.5 7.2 11.2 1 14.1 7.2 9.1 1.3 12.6 4.6 306 6 307 165 12.6 0 12.7 12.5 07/29/2006 02:30:00 10.4 1.2 15.6 6.8 10.4 1.1 15.3 7.2 8.1 1.2 14.1 5.7 303 6 302 165 12.6 0 12.7 12.5 07/29/2006 02:40:00 12.8 1.1 16.1 10.3 12.7 1.1 16.4 10.3 10.1 1.3 15.3 7.6 306 5 307 165 12.6 0.1 12.7 12.5 07/29/2006 02:50:00 13.4 1.5 17.2 8.8 13.4 1.5 17.2 8.8 10.8 1.5 15.3 7.2 306 6 305 165 12.4 0 12.5 12.2 07/29/2006 03:00:00 13.5 1.3 15.6 8.8 13.4 1.3 15.6 8.8 11.3 1.5 14.5 7.6 308 5 305 165 12.5 0 12.7 12.5 07/29/2006 03:10:00 13.6 1.2 16.4 10.3 13.5 1.2 16.1 10.3 11.5 1.5 15.6 8 310 5 317 165 12.7 0 12.7 12.5 07/29/2006 03:20:00 14.2 1.2 17.2 11.1 14.1 1.2 16.8 10.7 11.7 1.9 16.4 8 308 5 306 165 12.5 0 12.7 12.5 07/29/2006 03:30:00 11.4 1.5 14.1 7.6 11.4 1.4 14.5 7.6 9.1 1.2 13 6.5 306 6 302 165 12.6 0 12.7 12.5 07/29/2006 03:40:00 11 1.3 13.7 7.2 11 1.3 13.7 7.6 8.4 1 11.1 5.7 303 5 307 165 12.9 0.1 13 12.7 07/29/2006 03:50:00 12.9 2 17.2 9.1 12.9 2 17.2 8.8 9.5 1.4 13 6.5 301 5 305 165 12.9 0 13 12.7 07/29/2006 04:00:00 13.1 1.1 16.4 10.3 13.1 1.2 16.4 10.3 10.4 1.3 13.7 7.2 304 6 303 165 12.7 0 12.7 12.5 07/29/2006 04:10:00 12.9 1.8 16.1 6.5 12.9 1.8 16.4 6.8 10.6 1.6 14.1 6.1 306 7 302 165 12.5 0 12.7 12.5 07/29/2006 04:20:00 12.4 1.6 17.2 6.8 12.5 1.6 16.8 7.2 9.4 1.3 13 6.1 298 6 301 165 12.4 0 12.7 12.2 07/29/2006 04:30:00 12.4 1.3 14.9 9.1 12.4 1.3 14.9 9.1 9.3 1.3 13.3 6.1 299 6 298 165 12.3 0 12.5 12.2 07/29/2006 04:40:00 13.3 1.3 16.4 9.9 13.1 1.2 16.4 10.3 12 1.7 15.6 7.6 312 7 314 165 11.9 0 12.2 11.7 07/29/2006 04:50:00 14.4 1.5 19.1 10.3 14.2 1.5 19.1 10.7 14.4 1.5 17.6 9.5 317 5 308 165 11.9 0.1 12.2 11.7 07/29/2006 05:00:00 13.6 1.7 17.6 9.5 13.4 1.6 17.2 9.1 13.2 1.7 16.4 8.8 316 7 323 165 11.7 0.1 11.9 11.1 07/29/2006 05:10:00 14.6 1.2 18.3 11.5 14.5 1.3 17.9 11.1 12.9 1.7 17.2 8.8 310 6 309 165 11.5 0.1 11.7 11.1 07/29/2006 05:20:00 14.7 1.4 17.6 9.9 14.5 1.4 17.6 10.3 13.6 1.6 16.8 9.1 311 6 308 165 11.2 0 11.7 10.9 07/29/2006 05:30:00 14.7 2.8 21 9.5 14.5 2.7 20.6 9.5 13.4 3.2 19.9 8 311 7 313 165 11.2 0.2 11.9 10.9 07/29/2006 05:40:00 13.1 1.5 18.3 9.1 12.9 1.4 17.6 8.8 12.2 1.7 17.2 6.8 313 7 312 165 11.7 0 11.9 11.4 07/29/2006 05:50:00 11.5 1.3 15.6 8.8 11.4 1.3 16.1 8.4 10.1 1.5 14.5 6.1 307 8 295 165 11.2 0 11.4 10.9 07/29/2006 06:00:00 13.4 1.7 17.2 9.1 13.4 1.7 16.8 8.4 10.4 1.5 14.9 7.2 300 6 302 165 11.1 0 11.4 10.9 07/29/2006 06:10:00 14 1 16.1 10.3 14 1 16.1 10.3 10.2 1.1 14.1 8 298 5 297 165 11.1 0 11.4 10.9 07/29/2006 06:20:00 13.4 1 15.3 10.3 13.3 1 15.3 10.3 10.4 1.2 14.1 7.2 302 6 298 165 11.3 0 11.4 10.9 07/29/2006 06:30:00 14.2 1.3 17.2 9.5 14 1.3 16.4 9.5 11.9 1.5 16.8 8 307 5 306 165 11.5 0.1 11.9 11.1 07/29/2006 06:40:00 14.1 1.2 17.2 9.9 13.9 1.2 16.8 10.3 11 1.4 16.1 7.6 303 5 306 165 11.9 0 12.2 11.7 07/29/2006 06:50:00 14.2 1 16.8 10.7 14.1 1 16.8 10.7 10.8 1.2 14.5 8 305 5 302 165 11.9 0 12.2 11.9 07/29/2006 07:00:00 13.8 1.1 15.6 10.3 13.7 1.1 15.6 9.9 11.6 1.2 14.9 8 308 5 301 165 12.2 0.1 12.5 11.9 07/29/2006 07:10:00 13.2 0.9 14.9 9.9 13 0.9 14.9 9.5 11.9 1.1 14.5 8.4 312 5 311 165 12.4 0 12.7 12.2 07/29/2006 07:20:00 13 1.1 16.8 9.9 12.8 1 16.4 9.5 11.4 1.2 14.1 8.4 310 5 307 165 12.4 0 12.7 12.2 07/29/2006 07:30:00 14.3 1.1 16.4 11.1 14.3 1.2 16.8 11.5 11.6 1.3 15.3 7.6 307 4 304 165 12.7 0 12.7 12.5 07/29/2006 07:40:00 13.8 1.7 17.2 9.5 13.7 1.6 17.2 9.1 11.4 1.7 16.4 7.6 308 6 309 165 12.9 0.1 13 12.7 07/29/2006 07:50:00 13.8 1.1 17.2 10.7 13.7 1.1 17.2 10.7 10.6 1.5 14.1 7.6 306 6 304 165 13.2 0 13.3 13 07/29/2006 08:00:00 13.2 1.1 15.6 10.3 13.2 1.2 16.1 10.3 10 1.2 13.7 7.2 304 5 302 165 13.4 0 13.5 13 07/29/2006 08:10:00 12 0.9 14.1 9.5 12 1 14.1 9.5 9.1 1.1 11.8 6.5 297 5 295 165 13.5 0 13.8 13.3 07/29/2006 08:20:00 11.4 1.5 14.5 7.2 11.4 1.5 14.1 7.2 9.2 1.2 11.8 5.3 294 5 307 165 13.5 0.1 14.1 13.3 07/29/2006 08:30:00 11.5 1.8 15.6 6.8 11.5 1.7 15.3 6.8 9.6 1.9 13.7 4.9 307 6 305 165 14.2 0 14.6 13.5 07/29/2006 08:40:00 9 1.2 11.8 6.5 9 1.3 11.8 6.1 7.5 1.2 11.5 4.6 304 7 295 165 14.3 0 14.6 14.1 07/29/2006 08:50:00 8.8 0.8 11.1 6.5 8.8 0.9 11.1 6.5 7.5 0.9 9.9 4.9 307 6 309 165 14.5 0.1 14.6 14.1 07/29/2006 09:00:00 8.5 0.9 10.7 4.9 8.4 0.9 10.7 4.9 7.7 1 9.9 4.9 308 7 306 165 14.9 0.1 15.2 14.6 07/29/2006 09:10:00 7.7 1.1 9.9 4.9 7.7 1.1 9.9 4.9 6.3 1 9.5 3.4 298 9 305 165 15.5 0.2 16.3 15.2 07/29/2006 09:20:00 7.8 1.2 11.1 4.9 7.9 1.2 11.1 4.9 6.8 1.4 11.8 4.2 294 12 302 165 16.1 0 16.6 16 07/29/2006 09:30:00 7.5 1.5 11.5 2.3 7.6 1.6 11.5 3 6.5 1.8 10.7 1.1 291 15 321 165 16.6 0.3 17.1 16 07/29/2006 09:40:00 8.2 1.3 12.2 4.9 8.3 1.3 12.2 4.9 6.8 1.5 11.1 3.4 296 12 313 165 17 0 17.4 16.8 07/29/2006 09:50:00 8.5 1.2 11.8 4.9 8.7 1.3 13 5.7 7.8 1.5 12.6 4.6 283 8 268 165 16.9 0.1 17.4 16.8 07/29/2006 10:00:00 9.3 1.9 13.7 4.2 9.3 1.9 13 4.6 8.1 2 12.2 3.4 291 9 287 165 17 0.1 17.4 16.8 07/29/2006 10:10:00 10.3 1.4 13.7 6.5 10.3 1.4 13.7 6.1 8.5 1.5 12.2 4.9 296 9 304 165 17 0 17.4 16.8 07/29/2006 10:20:00 12 1.4 16.4 7.2 12 1.4 16.4 7.6 10 1.7 16.1 6.1 302 8 288 165 17 0 17.4 16.8 07/29/2006 10:30:00 11.3 1 14.9 8.8 11.4 1 14.5 9.1 9.7 1.2 13 6.8 295 8 307 165 16.8 0 17.1 16.8 07/29/2006 10:40:00 10 1 12.6 6.8 10.1 1 13 7.2 9.7 1.3 12.6 6.1 283 7 289 165 17.3 0.2 17.7 16.8 07/29/2006 10:50:00 10.8 1.5 14.5 6.8 10.7 1.4 14.5 7.2 8.8 1.2 12.2 5.7 296 9 298 165 17.3 0.1 18 16.8 07/29/2006 11:00:00 11.4 1.6 15.6 8 11.3 1.5 15.6 8.4 9.4 1.3 15.3 6.1 298 9 286 165 17.2 0 17.7 17.1 07/29/2006 11:10:00 10.1 1.4 14.9 6.5 10.1 1.4 14.5 6.5 8.8 1.8 15.3 4.2 293 11 279 165 17.3 0.1 18 16.8 07/29/2006 11:20:00 14.5 2.3 19.1 7.6 14.3 2.2 18.7 7.6 11.7 1.7 17.6 7.2 306 7 299 165 17.5 0.2 18.2 17.1 07/29/2006 11:30:00 16.7 1.5 20.6 12.6 16.5 1.6 20.2 12.2 13.1 2 20.6 8.8 304 6 314 165 17.5 0.1 18.2 17.4 07/29/2006 11:40:00 17.9 1.3 21.8 14.1 17.8 1.3 21.4 13.7 14.1 2.2 21 9.9 305 6 308 165 17.4 0 18 17.1 07/29/2006 11:50:00 16.5 1.7 20.6 11.1 16.4 1.8 20.2 10.3 12.8 1.8 18.3 8.8 304 5 299 165 17.4 0.1 18 17.1 07/29/2006 12:00:00 13.9 1.3 17.6 9.5 13.7 1.3 17.2 10.3 11.2 1.7 16.8 6.8 304 7 317 165 17.7 0 18.2 17.4 07/29/2006 12:10:00 15.9 2.1 20.6 10.3 15.7 2.1 20.6 9.5 12.7 1.9 16.4 7.6 306 5 301 165 17.3 0.1 17.7 16.8 07/29/2006 12:20:00 16.4 1.6 20.2 11.1 16.2 1.6 20.2 10.7 13 1.8 19.1 7.6 304 5 302 165 17.1 0 17.7 16.8 07/29/2006 12:30:00 16.1 1.6 20.2 10.7 16 1.6 20.2 10.3 11.8 1.4 15.3 8.8 301 5 300 165 17 0 17.7 16.8 07/29/2006 12:40:00 14.8 1.4 17.6 10.7 14.7 1.4 17.6 11.1 12.4 2.3 17.6 7.6 305 8 307 165 17.1 0 17.7 16.8 07/29/2006 12:50:00 14.5 1.5 17.6 9.9 14.4 1.5 17.6 10.3 12 1.7 16.1 8 307 6 302 165 17.1 0 17.7 16.8 07/29/2006 13:00:00 14.9 1.7 19.5 11.1 14.8 1.7 19.5 11.5 12 1.7 16.4 8 306 8 298 165 17.1 0.1 17.7 16.8 07/29/2006 13:10:00 15.8 1.3 19.1 10.7 15.8 1.3 19.1 10.7 12.1 1.8 17.6 8.8 301 6 310 165 16.8 0 17.4 16.6 07/29/2006 13:20:00 16.3 1.6 20.2 11.8 16.2 1.6 19.9 11.8 13.1 2 19.5 9.1 305 6 297 165 16.8 0.1 17.4 16.6 07/29/2006 13:30:00 17.5 1.1 20.6 14.5 17.4 1.1 20.6 14.5 14.6 1.7 19.5 10.3 308 5 316 165 17 0.1 17.4 16.8 07/29/2006 13:40:00 17.2 1.4 21.4 12.6 16.9 1.4 20.6 12.6 16.1 1.6 19.9 11.1 314 6 314 165 17.2 0.2 17.7 16.8 07/29/2006 13:50:00 18.6 1.5 21.8 13.7 18.4 1.5 21.4 13 17.7 1.7 21 12.2 314 4 310 165 17.1 0 18 16.8 07/29/2006 14:00:00 20.5 1.3 23.3 16.8 20.3 1.4 23.3 16.4 17.7 1.7 21.8 11.8 310 4 322 165 17.3 0.1 17.7 16.8 07/29/2006 14:10:00 19.6 1.7 22.9 14.9 19.4 1.7 23.3 14.9 17.1 1.8 21.4 12.2 311 5 308 165 17.2 0 17.7 16.8 07/29/2006 14:20:00 17.1 2 22.9 11.1 16.8 1.9 22.6 11.5 14.2 2.4 22.1 7.2 307 6 313 165 17.7 0.2 18.5 17.4 07/29/2006 14:30:00 13.5 1.9 18.3 7.2 13.3 1.7 17.2 7.2 10.3 2 15.3 4.2 303 7 295 165 18.2 0 18.8 18 07/29/2006 14:40:00 11.4 1.8 16.1 6.5 11.3 1.7 15.6 6.5 8.5 1.9 13 2.6 303 10 305 165 18.8 0 19.1 18.5 07/29/2006 14:50:00 13.7 1.6 17.2 9.1 13.5 1.6 17.2 9.5 11.1 1.7 15.6 6.1 305 7 307 165 18.3 0.2 18.8 17.7 07/29/2006 15:00:00 14.8 1.4 18.3 10.3 14.6 1.4 18.7 10.7 11.9 1.8 17.2 8.4 306 5 314 165 17.5 0.1 18 17.1 07/29/2006 15:10:00 16.8 1.3 19.9 11.8 16.7 1.4 19.5 12.2 12.5 1.4 16.8 9.1 304 5 297 165 17 0.1 17.7 16.8 07/29/2006 15:20:00 16.9 1.5 20.6 12.2 16.8 1.5 20.6 12.2 13.3 1.9 18.7 8.8 304 7 304 165 17 0 17.4 16.8 07/29/2006 15:30:00 14.2 1.7 17.9 10.3 14.2 1.7 17.9 10.3 12.2 1.8 17.9 8.4 307 8 302 165 17.1 0.1 17.7 16.8 07/29/2006 15:40:00 13.5 1.6 19.1 9.1 13.4 1.6 19.1 9.1 11.6 2.1 16.8 6.1 310 8 306 165 17.3 0 18 17.1 07/29/2006 15:50:00 13.4 1.5 17.9 9.1 13.4 1.5 17.9 9.5 11 1.9 15.3 6.8 304 8 298 165 17.3 0 17.4 16.8 07/29/2006 16:00:00 10.2 1.5 14.5 7.2 10.2 1.5 14.5 7.2 8.7 1.7 13.7 4.9 300 9 301 165 17.5 0 18 17.4 07/29/2006 16:10:00 10.6 1.3 13.7 8 10.6 1.3 13.7 8.4 8.3 1.2 12.6 6.1 301 6 300 165 17.9 0 18.2 17.7 07/29/2006 16:20:00 11.1 1.7 16.4 7.6 11 1.7 16.8 7.6 9.3 1.3 12.6 6.1 306 6 303 165 17.8 0 18.5 17.7 07/29/2006 16:30:00 10.2 1.7 13.7 6.1 10.2 1.7 13.3 6.5 8.1 1.3 11.5 5.3 302 8 303 165 18.1 0.2 18.8 17.7 07/29/2006 16:40:00 9.8 1.3 12.6 6.1 9.7 1.3 13 6.5 8.1 1.4 11.5 4.6 299 10 310 165 18 0 18.2 17.7 07/29/2006 16:50:00 8.7 1.2 11.8 5.7 8.7 1.2 11.8 5.7 7.4 1.4 11.8 3.8 292 8 284 165 17.9 0 18.2 17.7 07/29/2006 17:00:00 7.3 1 9.9 4.6 7.5 1 10.3 4.6 6.4 1.3 9.5 3.4 288 9 281 165 18.3 0.2 18.8 17.7 07/29/2006 17:10:00 6.1 2.1 10.3 1.1 6.3 2.1 10.7 1.1 5.7 2.1 10.7 0.4 293 15 281 165 18.5 0.1 19.1 18 07/29/2006 17:20:00 4.1 1.2 6.5 1.1 4.4 1.1 7.2 1.9 3.7 1.2 6.5 0.7 299 22 289 165 18.9 0 19.4 18.5 07/29/2006 17:30:00 5 1.5 8 0.7 5.1 1.5 8 0.7 4.3 1.4 7.2 0.4 305 11 294 165 18.8 0.2 19.1 18.2 07/29/2006 17:40:00 7.2 1.3 9.9 3.4 7.2 1.2 9.9 3.4 6.1 1.4 10.3 3 304 11 294 165 18 0.2 18.5 17.7 07/29/2006 17:50:00 8.6 1.1 11.5 5.3 8.6 1.1 11.5 4.6 6.9 1.1 10.3 3.4 303 7 310 165 17.8 0 18 17.4 07/29/2006 18:00:00 8.5 1.5 11.8 4.9 8.4 1.5 11.8 4.9 7.1 1.5 11.5 3 301 7 311 165 17.3 0 17.7 16.8 07/29/2006 18:10:00 8.4 1.5 11.8 3.8 8.4 1.4 11.5 4.6 6.8 1.3 10.7 3 301 10 309 165 17 0 17.4 16.8 07/29/2006 18:20:00 7.8 1.5 10.7 3.4 7.8 1.4 10.7 4.2 6.4 1.5 10.3 1.5 308 9 309 165 16.8 0 17.4 16.8 07/29/2006 18:30:00 7.2 1.7 11.1 3 7.2 1.6 11.1 3.4 5.8 1.7 10.7 2.3 304 10 297 165 16.9 0.1 17.4 16.8 07/29/2006 18:40:00 7.1 1.2 9.9 2.6 7.1 1.1 9.9 2.6 5.2 1.3 8.4 1.9 305 12 304 165 16.5 0 16.8 16.3 07/29/2006 18:50:00 6 1.3 8.8 1.9 6.1 1.3 8.8 2.3 4.8 1.3 8 0.7 313 15 308 165 16.7 0.1 17.1 16.3 07/29/2006 19:00:00 4.7 1.8 8.4 0.4 4.9 1.8 9.1 0.4 3.6 1.7 8 0.4 299 21 312 165 16.2 0.1 16.8 16 07/29/2006 19:10:00 3.3 1.6 7.6 0.4 3.6 1.5 7.6 0.4 2.6 1.3 6.1 0.4 304 38 328 165 16 0 16.3 15.7 07/29/2006 19:20:00 7.1 1.2 9.9 4.2 7.2 1.2 9.9 4.2 6.2 1.3 9.5 3.4 287 8 282 165 15.6 0 16 15.5 07/29/2006 19:30:00 7.8 1.1 10.3 4.6 8.1 1 10.7 5.3 7.7 1.1 10.3 4.2 281 7 291 165 15.1 0.1 15.7 14.9 07/29/2006 19:40:00 8.2 1 9.9 4.9 8.3 1 9.9 4.9 6.6 1.2 9.9 4.2 297 6 291 165 14.8 0 15.2 14.6 07/29/2006 19:50:00 6.3 1 8.8 3.8 6.4 1 9.1 4.2 5.2 0.9 7.6 2.6 303 8 302 165 14.7 0 14.9 14.6 07/29/2006 20:00:00 7.2 1.2 10.3 3.8 7.2 1.2 10.7 3.8 6 1.1 8.8 3.8 306 10 308 165 14.4 0 14.6 14.1 07/29/2006 20:10:00 7.1 1.9 11.5 1.9 7.3 1.8 11.5 2.3 5.5 2 10.7 0.4 303 18 290 165 13.7 0.2 14.4 13.3 07/29/2006 20:20:00 5 2.1 9.5 0.4 5.4 2 9.5 0.4 3.9 1.5 8 0.4 281 32 281 165 13.2 0 13.5 13 07/29/2006 20:30:00 3.1 1.8 8 0.4 3.6 1.8 9.1 0.4 2.5 1.5 8.4 0.4 295 82 295 165 13.2 0 13.3 13 07/29/2006 20:40:00 6.1 1.5 11.5 3 6.4 1.3 11.8 4.2 5.5 1.5 11.8 2.3 288 20 284 165 12.6 0 13 12.2 07/29/2006 20:50:00 9.3 1.3 13 6.1 9.3 1.3 12.6 6.1 7.3 1.1 9.5 4.6 302 9 299 165 12.5 0 12.7 12.2 07/29/2006 21:00:00 10.8 1.6 14.9 6.5 10.7 1.5 14.5 6.5 8.8 1.6 12.6 5.3 302 8 302 165 12.3 0 12.5 11.9 07/29/2006 21:10:00 11.9 1.5 16.4 7.6 11.9 1.5 16.4 7.2 9.7 1.2 13 7.6 302 7 296 165 12.1 0 12.7 11.9 07/29/2006 21:20:00 12.4 1.5 15.3 9.5 12.3 1.5 15.3 9.1 9.7 1.5 15.3 7.2 301 6 298 165 11.9 0.1 12.5 11.9 07/29/2006 21:30:00 12.8 1.5 16.1 8.8 12.7 1.5 16.1 9.1 9.6 1.3 13.3 6.5 299 6 294 165 11.9 0 11.9 11.7 07/29/2006 21:40:00 10.7 1.8 15.6 7.2 10.8 1.8 15.6 7.6 9.3 2.4 15.3 5.3 289 8 284 165 12 0 12.2 11.7 07/29/2006 21:50:00 10.4 1.1 13.3 7.2 10.5 1.2 13.3 7.6 9.2 1.6 13.3 5.3 291 8 290 165 12.1 0 12.5 11.7 07/29/2006 22:00:00 10.1 0.9 12.2 7.6 10.2 1 12.6 7.6 7.8 1.1 11.1 5.3 296 5 293 165 11.9 0.1 12.2 11.1 07/29/2006 22:10:00 11.1 1 13.7 8.8 11.1 0.9 14.1 9.1 8.2 0.9 11.5 6.5 300 5 301 165 11.7 0 11.9 11.7 07/29/2006 22:20:00 11.1 1.5 14.1 8 11.1 1.5 14.1 8 8.8 1.4 13.7 5.7 300 8 293 165 11.8 0 11.9 11.4 07/29/2006 22:30:00 12.4 1.5 15.6 8 12.4 1.5 15.3 8 9 1.1 11.8 5.7 298 6 301 165 11.7 0 11.9 11.1 07/29/2006 22:40:00 12.9 1.2 16.1 9.5 12.8 1.2 15.6 9.5 9.9 1.5 13.7 6.5 301 6 305 165 11.5 0 11.7 10.9 07/29/2006 22:50:00 12.1 1.7 15.6 7.2 12 1.8 15.6 7.2 9.5 1.5 16.4 4.9 301 8 292 165 11.4 0 11.7 10.9 07/29/2006 23:00:00 11.6 1.5 14.5 6.5 11.6 1.5 14.5 6.8 9 1.2 12.2 6.1 301 6 305 165 11.3 0 11.7 11.1 07/29/2006 23:10:00 11.8 1.3 16.1 8.8 11.8 1.3 15.6 8.8 8.8 1.2 12.6 6.1 298 6 293 165 11.1 0 11.4 10.9 07/29/2006 23:20:00 12.3 1.3 15.6 9.1 12.2 1.3 15.6 9.1 9.1 1.2 13 6.8 298 6 298 165 11 0 11.1 10.9 07/29/2006 23:30:00 13.1 1.1 15.6 9.5 13.1 1.1 15.6 9.1 9.6 1.1 12.6 6.5 301 5 293 165 10.7 0 11.1 10.9 07/29/2006 23:40:00 12.9 1.2 16.1 9.5 12.9 1.2 16.1 9.9 9.1 1 12.2 6.5 299 5 297 165 10.7 0 10.9 10.6 07/29/2006 23:50:00 12.9 1.2 16.1 9.9 12.8 1.2 15.6 10.3 9.8 1.1 13 6.5 302 6 297 165 10.5 0 10.9 10.3 07/30/2006 00:00:00 13.7 1.1 17.6 10.3 13.6 1.2 17.2 10.7 10.6 1.3 14.1 7.2 304 6 288 165 10.7 0.1 10.9 10.1 07/30/2006 00:10:00 13.3 1.5 16.8 9.9 13.3 1.5 16.8 9.5 9.9 1.4 14.5 6.5 299 6 302 165 10.7 0 10.9 10.6 07/30/2006 00:20:00 12.9 1.5 16.8 9.1 12.9 1.5 17.2 9.1 9.8 1.7 16.4 6.5 296 7 277 165 10.5 0 10.9 10.3 07/30/2006 00:30:00 13.6 1.5 18.3 9.9 13.6 1.5 18.3 9.9 10.1 1.3 14.1 8 300 5 303 165 10.3 0 10.6 10.3 07/30/2006 00:40:00 14.5 1.7 18.7 9.9 14.5 1.7 19.1 9.9 11 1.4 15.3 6.8 299 6 292 165 10.9 0.1 11.1 10.3 07/30/2006 00:50:00 14.2 2.1 18.7 9.9 14.2 2.1 18.7 9.5 10.9 1.7 16.8 6.8 298 7 296 165 11.1 0 11.4 10.9 07/30/2006 01:00:00 14.9 1.5 18.7 11.1 14.8 1.5 18.3 10.7 11.4 1.4 15.6 8 301 7 296 165 10.9 0.2 11.4 10.9 07/30/2006 01:10:00 15.4 1.4 19.5 10.7 15.2 1.4 19.1 9.9 11.8 1.3 15.6 8.4 298 7 301 165 11 0.2 11.4 10.9 07/30/2006 01:20:00 14.5 1.5 18.3 10.3 14.5 1.5 18.3 9.9 11.1 1.7 16.8 8 296 8 285 165 11.3 0 11.7 11.1 07/30/2006 01:30:00 16.4 2.3 22.9 9.5 16.3 2.3 21.8 9.9 13.2 2.2 19.1 8 293 8 294 165 11.5 0.1 11.9 10.9 07/30/2006 01:40:00 17.1 2 22.9 11.8 17.2 2 22.6 11.8 14.5 2.9 23.3 8.8 289 7 297 165 11.7 0 11.9 11.7 07/30/2006 01:50:00 16.4 2 21.4 11.5 16.4 2.1 21.4 11.1 14 2.7 21.4 8.4 292 8 286 165 11.5 0 11.7 11.4 07/30/2006 02:00:00 17.9 2 23.7 10.7 18 2 23.7 10.3 16.1 2.6 23.3 10.3 288 7 281 165 11.3 0 11.4 11.1 07/30/2006 02:10:00 17.5 1.7 22.1 12.6 17.5 1.8 22.1 12.2 15 2.5 22.6 9.5 289 7 285 165 11.3 0 11.4 11.1 07/30/2006 02:20:00 12.8 2.5 19.9 6.1 12.7 2.5 20.2 6.5 10.5 2.4 17.9 5.7 290 9 291 165 11.1 0 11.4 10.9 07/30/2006 02:30:00 7.4 1.7 11.5 3 7.3 1.7 11.1 3 5.9 2 10.7 1.9 291 12 279 165 10.5 0.2 11.1 9.8 07/30/2006 02:40:00 8.9 1.7 13 4.2 8.9 1.7 13.3 4.6 7.3 2 13.3 3 290 12 304 165 10.5 0.1 10.9 10.3 07/30/2006 02:50:00 13.6 2.2 19.5 7.2 13.4 2.2 19.1 7.2 10.7 1.7 16.8 6.8 300 8 293 165 10.6 0.2 10.9 10.3 07/30/2006 03:00:00 15.9 2.2 20.2 9.9 15.8 2.3 20.2 9.9 12.8 2.4 18.7 7.6 293 6 293 165 10.6 0.2 10.9 10.3 07/30/2006 03:10:00 14.1 1.2 17.9 11.1 13.9 1.2 16.8 11.1 10.8 1.6 15.6 6.8 297 6 289 165 10.5 0.2 10.9 9.8 07/30/2006 03:20:00 16 1.7 19.9 11.5 15.9 1.7 19.5 11.1 11.5 1.5 17.2 8 299 5 298 165 10.5 0.3 10.9 9.8 07/30/2006 03:30:00 15.1 1.3 18.7 11.5 15 1.3 18.3 11.5 11.2 1.3 16.1 8 299 5 305 165 10.4 0.1 10.9 9.8 07/30/2006 03:40:00 16.1 1.7 20.2 11.5 16.1 1.7 20.2 11.1 13 2 19.1 8.8 296 8 294 165 10.2 0.2 10.6 9.6 07/30/2006 03:50:00 16.6 1.5 19.9 12.6 16.6 1.5 20.2 12.6 14.2 2.2 18.7 9.1 290 7 302 165 10.5 0.2 10.9 9.8 07/30/2006 04:00:00 15 1.5 18.3 11.5 15 1.6 18.7 11.1 12.7 2.5 18.3 8.4 291 7 287 165 10.5 0.2 10.9 10.3 07/30/2006 04:10:00 11.4 2.2 17.6 6.5 11.3 2.2 17.9 6.5 9.4 1.7 15.6 5.7 300 11 290 165 10.6 0.2 11.1 10.3 07/30/2006 04:20:00 12.1 1.8 16.4 6.8 12 1.8 16.4 6.5 9.9 1.5 14.9 4.9 300 7 299 165 10.4 0 10.9 9.8 07/30/2006 04:30:00 13.6 1.5 17.6 9.9 13.4 1.5 17.2 9.9 10.6 1.7 16.4 7.6 303 6 304 165 10.1 0.2 10.6 9.6 07/30/2006 04:40:00 12.8 1.1 16.1 9.5 12.7 1.1 16.1 9.1 10.1 1.5 15.3 6.5 300 6 294 165 9.9 0 10.3 9.3 07/30/2006 04:50:00 10.4 2.3 14.9 6.1 10.3 2.2 14.9 6.1 8.3 1.6 12.6 4.6 302 7 300 165 9.6 0.1 9.8 9 07/30/2006 05:00:00 12.2 1.5 15.6 8.8 12.1 1.5 15.3 8.8 9.5 1.3 13.3 5.7 303 6 296 165 9.8 0 9.8 9.3 07/30/2006 05:10:00 11.4 1.6 14.9 7.2 11.4 1.6 14.9 7.2 9.2 1.3 13.7 6.1 299 8 294 165 9.7 0 9.8 9.6 07/30/2006 05:20:00 13.4 1.4 16.8 7.6 13.4 1.4 16.8 8 10.5 1.7 15.3 7.2 298 7 295 165 9.8 0 10.1 9.3 07/30/2006 05:30:00 15.5 1.6 19.1 10.3 15.4 1.7 19.1 10.7 12.6 1.9 17.6 8.8 302 8 293 165 9.8 0 10.1 9.3 07/30/2006 05:40:00 16.1 2.8 21 10.3 16 2.7 20.6 10.3 12.6 2.4 17.6 7.6 298 8 301 165 10.1 0.2 10.6 9.6 07/30/2006 05:50:00 17.5 1.7 21.8 13.3 17.3 1.7 21.4 12.2 13.4 1.5 18.7 9.1 301 5 306 165 10.3 0 10.6 9.8 07/30/2006 06:00:00 15.6 1.9 19.5 9.9 15.4 1.9 19.5 9.9 12.2 1.7 17.6 8 299 6 298 165 10.3 0 10.6 9.6 07/30/2006 06:10:00 17.8 1.5 21.4 14.5 17.7 1.5 21.8 14.1 13.2 1.5 18.3 9.9 299 6 301 165 10.3 0 10.6 9.6 07/30/2006 06:20:00 14.1 2 18.3 9.5 14 2 17.9 9.9 11.6 1.9 17.6 7.6 296 8 296 165 10.3 0 10.6 9.8 07/30/2006 06:30:00 13 1.3 16.8 8 13 1.3 16.4 7.6 10.4 1.5 14.9 6.8 303 6 300 165 10.5 0.2 10.9 9.8 07/30/2006 06:40:00 12.3 1.3 16.1 8.8 12.2 1.3 15.3 8.8 10.6 1.7 15.3 6.8 306 7 322 165 10.6 0.1 10.9 10.3 07/30/2006 06:50:00 11.8 1.3 15.3 8.8 11.9 1.4 15.3 8.4 9.6 1.5 14.1 6.1 295 8 295 165 10.8 0 11.1 10.6 07/30/2006 07:00:00 13.9 1.2 17.6 11.5 14 1.2 17.6 11.1 10.5 1.6 16.1 7.2 297 6 284 165 11.1 0.1 11.4 10.9 07/30/2006 07:10:00 14.9 1.5 18.3 11.5 14.9 1.5 18.3 11.5 11.2 1.7 17.6 7.6 298 6 293 165 11.4 0 11.7 11.1 07/30/2006 07:20:00 12 1.7 16.1 7.2 12 1.6 16.1 7.2 9.8 1.7 15.6 4.9 299 8 296 165 11.8 0 12.2 11.7 07/30/2006 07:30:00 8.2 2.7 14.1 0.7 8.2 2.6 13.7 1.5 6.6 2.6 13.3 0.7 292 15 287 165 12.6 0.3 13 11.9 07/30/2006 07:40:00 4.2 1.8 9.1 0.7 4.7 1.6 9.1 1.1 4.1 1.6 7.6 0.4 273 18 285 165 13.2 0 13.3 13 07/30/2006 07:50:00 8.1 1.4 11.1 4.9 8.4 1.3 11.5 5.3 7.4 1.3 11.1 4.2 286 9 286 165 12.7 0 13 12.5 07/30/2006 08:00:00 8.9 1.4 12.6 4.9 8.9 1.4 12.6 4.9 7.6 1.4 12.2 4.2 297 10 285 165 12.5 0 12.7 12.5 07/30/2006 08:10:00 7.9 1.5 11.8 4.6 7.9 1.5 12.2 4.6 6.6 1.6 10.3 3.4 296 9 282 165 12.8 0 13 12.5 07/30/2006 08:20:00 8.7 1.1 11.8 5.3 8.8 1.2 11.8 5.7 7.8 1.3 11.1 3.8 290 9 282 165 12.9 0 13 12.7 07/30/2006 08:30:00 9.3 1.3 12.6 5.3 9.7 1.2 13 6.8 9.3 1.4 13 4.9 281 8 273 165 12.9 0.1 13.3 12.7 07/30/2006 08:40:00 10.8 1.7 16.1 6.8 10.9 1.8 16.4 6.8 10.2 2.3 16.1 5.3 288 8 282 165 13.1 0 13.3 13 07/30/2006 08:50:00 10 1.6 13.7 6.1 10.1 1.6 14.1 5.7 9.1 1.7 13.7 4.6 286 7 288 165 13.5 0 13.5 13.3 07/30/2006 09:00:00 9.1 1.4 14.1 5.7 9.1 1.3 13.7 5.7 7.8 1.4 11.5 3.8 298 12 292 165 13.9 0.2 14.1 13.3 07/30/2006 09:10:00 9.9 1.7 13.7 4.9 9.8 1.7 13.7 5.3 8.2 1.6 12.6 3.4 302 10 298 165 14 0 14.4 13.5 07/30/2006 09:20:00 10.2 1.7 17.2 5.7 10.1 1.7 16.8 6.1 8.9 1.7 13.7 5.7 305 10 297 165 14 0.1 14.6 13.8 07/30/2006 09:30:00 11.9 1.9 16.8 6.8 11.8 1.9 16.4 6.8 10.2 2.1 16.4 4.9 302 12 302 165 13.8 0.2 14.6 13.3 07/30/2006 09:40:00 12.7 1.6 16.1 7.6 12.8 1.7 16.4 7.6 12 2.2 16.4 5.3 289 13 266 165 13.6 0.3 14.6 13 07/30/2006 09:50:00 12.6 2 16.4 6.8 12.5 2 16.4 6.8 10.4 1.7 15.3 5.3 305 8 294 165 14.3 0 14.6 14.1 07/30/2006 10:00:00 11.7 2.5 18.3 5.7 11.6 2.5 18.3 5.7 9.8 2.1 15.6 4.9 305 10 305 165 14.6 0.1 15.2 14.1 07/30/2006 10:10:00 13.2 1.7 17.2 8.4 13 1.7 16.8 8.8 10.6 1.9 16.4 5.3 303 8 297 165 13.2 0.3 14.4 13 07/30/2006 10:20:00 10.1 3.2 15.6 3 10 3.1 15.6 3 8 2.7 13 1.5 303 12 300 165 13 0.1 13.5 12.7 07/30/2006 10:30:00 8.2 2.5 12.6 2.3 8.1 2.4 12.6 3 6.3 2.4 12.6 1.5 295 14 293 165 13.2 0 13.3 13 07/30/2006 10:40:00 8.9 1.9 13 4.6 8.9 1.8 13 4.6 7.5 1.9 12.6 3 298 9 289 165 12.9 0.1 13.3 12.5 07/30/2006 10:50:00 8.6 1.2 11.8 5.7 8.6 1.3 11.8 5.7 7.4 1.3 11.1 4.6 300 9 295 165 12.6 0 12.7 12.5 07/30/2006 11:00:00 11.2 1.7 16.1 7.2 11.3 1.7 15.6 7.6 10.2 1.9 14.9 6.5 287 6 288 165 12.9 0.1 13 12.5 07/30/2006 11:10:00 11.4 1.2 14.1 8 11.5 1.2 13.7 8.4 10.2 1.6 13.7 5.7 288 7 291 165 12.6 0.1 13 12.5 07/30/2006 11:20:00 8.6 1.3 11.1 4.9 8.6 1.3 11.5 4.6 7.4 1.3 10.7 3.8 303 9 289 165 12.7 0.1 13 12.5 07/30/2006 11:30:00 6.9 1.3 10.3 4.2 7 1.3 10.3 4.6 6.2 1.1 9.9 3.8 290 10 293 165 13.3 0 13.5 13 07/30/2006 11:40:00 4.4 1 6.8 1.9 4.7 1 7.2 2.3 4.3 1 7.2 1.5 280 13 293 165 13.5 0 13.8 13.3 07/30/2006 11:50:00 5.6 1.7 10.3 2.3 6.2 1.7 11.1 3 6 1.8 10.3 2.6 277 12 280 165 13.1 0.2 13.5 12.7 07/30/2006 12:00:00 8.6 1.9 12.6 3.8 8.9 1.7 12.6 4.6 8 1.7 11.8 4.2 285 12 291 165 12.7 0 13 12.7 07/30/2006 12:10:00 5.7 1.8 9.9 1.5 6.2 1.7 10.7 3.4 5.9 1.9 11.1 2.3 281 13 284 165 12.6 0 12.7 12.5 07/30/2006 12:20:00 3.2 1.2 5.7 0.4 3.3 1.2 5.7 0.4 3 1.1 5.3 0.4 321 17 317 165 13 0 13.3 12.7 07/30/2006 12:30:00 4.7 2.2 11.1 0.4 5 2.3 11.5 0.7 4.5 2.3 11.1 0.7 295 26 284 165 12.9 0 13.3 12.5 07/30/2006 12:40:00 6.8 1.7 11.8 3 6.8 1.6 12.6 3.4 6 1.7 11.5 1.9 311 21 309 165 12.7 0 13 12.5 07/30/2006 12:50:00 6.5 2.8 12.6 1.1 6.6 2.8 13 2.3 5.2 2.3 10.3 1.1 304 17 295 165 12.9 0 13 12.7 07/30/2006 13:00:00 10.8 2 15.3 6.1 10.8 1.9 15.3 6.1 9.1 2.3 14.9 4.2 292 11 306 165 12.7 0 13 12.5 07/30/2006 13:10:00 12.4 1.6 16.1 9.1 12.4 1.6 16.1 9.1 10.6 2.2 16.4 6.5 294 9 311 165 12.4 0 12.7 12.5 07/30/2006 13:20:00 15.2 2.5 21.4 9.1 15.2 2.5 21.4 9.1 12.6 2.7 19.9 6.8 293 7 292 165 12.7 0 12.7 12.5 07/30/2006 13:30:00 15.2 1.7 19.5 10.7 15.2 1.7 19.5 10.7 12.7 1.9 18.3 8.4 293 7 295 165 13.2 0.2 13.8 12.7 07/30/2006 13:40:00 14.8 1.6 19.5 10.3 14.7 1.6 19.5 10.7 12.7 1.7 17.9 8.4 305 11 306 165 13.7 0.2 14.4 13.3 07/30/2006 13:50:00 13.4 1.6 17.9 9.9 13.3 1.6 17.6 9.1 10.9 1.7 15.6 6.8 305 7 306 165 13 0.1 13.5 12.7 07/30/2006 14:00:00 11.8 1.7 15.6 6.8 11.7 1.7 15.6 6.8 9.6 1.5 15.3 5.7 301 8 302 165 12.9 0 13 12.7 07/30/2006 14:10:00 12.6 2.1 19.5 7.6 12.5 2.1 19.5 7.6 10.6 2.2 17.2 6.1 303 10 315 165 12.9 0.1 13 12.7 07/30/2006 14:20:00 13.1 2.1 17.9 8.8 13 2.1 17.9 8.4 10.5 1.9 15.6 6.1 305 6 304 165 13 0 13.3 12.7 07/30/2006 14:30:00 12.3 2.1 17.2 7.2 12.3 2 16.8 7.6 10 1.8 14.9 6.1 301 8 304 165 13.1 0 13.3 13 07/30/2006 14:40:00 14.2 1.6 18.7 9.5 14.1 1.6 18.7 9.5 10.8 1.5 15.3 7.6 303 5 303 165 12.8 0 13.3 12.5 07/30/2006 14:50:00 13.6 1.6 17.9 9.5 13.6 1.7 18.3 9.5 10.7 1.5 15.3 7.2 300 6 297 165 12.9 0.1 13 12.5 07/30/2006 15:00:00 11.6 1.8 15.3 4.9 11.6 1.8 15.3 5.3 9.4 1.7 13.3 4.6 294 7 291 165 13.7 0.3 14.1 13 07/30/2006 15:10:00 10.6 1.9 15.3 4.9 10.5 1.8 15.3 4.9 8.9 1.9 14.5 3.4 305 9 312 165 13.8 0.3 14.4 13 07/30/2006 15:20:00 10.1 2.3 14.1 5.7 10.1 2.2 14.5 4.6 8.5 2.1 14.1 4.6 303 10 312 165 13.2 0 13.5 13 07/30/2006 15:30:00 9.2 1.7 13 6.1 9.3 1.7 13.7 5.7 8.2 1.9 12.6 4.9 296 15 304 165 13.1 0.2 13.5 12.7 07/30/2006 15:40:00 10.4 1.5 14.9 6.8 10.5 1.6 15.3 6.5 9.1 1.8 14.1 5.7 291 10 275 165 12.8 0.1 13.3 12.5 07/30/2006 15:50:00 11.3 1.9 15.6 6.5 11.4 1.9 16.4 6.5 9.9 2.4 15.3 4.6 291 10 287 165 12.8 0.2 13.3 12.5 07/30/2006 16:00:00 12.1 2.3 17.9 7.2 12.3 2.4 18.3 6.8 11.4 2.7 17.9 5.3 286 8 277 165 12.3 0 12.7 12.2 07/30/2006 16:10:00 11.5 1.7 16.1 7.2 11.7 1.8 16.4 6.8 10.7 2.4 15.6 5.7 289 13 287 165 12.5 0 12.7 12.5 07/30/2006 16:20:00 9.5 1.4 13 6.5 9.5 1.3 13 6.8 8 1.4 12.6 5.3 299 10 313 165 12.5 0 12.7 12.5 07/30/2006 16:30:00 11.9 1.5 16.1 6.8 11.8 1.5 16.1 6.5 10.3 1.6 16.4 6.5 304 11 310 165 12.4 0.1 13 12.2 07/30/2006 16:40:00 11.2 1.5 15.6 6.1 11.1 1.5 15.6 4.9 9.9 1.7 14.1 5.3 307 8 304 165 12.3 0 12.7 12.2 07/30/2006 16:50:00 11.2 1.8 17.2 7.2 11.1 1.8 17.2 6.8 9.3 1.6 13.7 5.3 303 9 301 165 12.3 0.1 12.7 11.9 07/30/2006 17:00:00 12.8 1.9 17.6 8.4 12.7 1.8 17.6 8.4 10.6 1.7 15.3 6.5 303 10 303 165 12.1 0 12.2 11.9 07/30/2006 17:10:00 13.6 1.7 17.6 8.4 13.4 1.6 17.2 9.1 11.1 1.7 15.6 6.8 305 7 301 165 12.1 0 12.2 11.9 07/30/2006 17:20:00 12.1 1.8 16.8 8 12 1.8 16.8 7.6 10.2 2 16.1 4.9 301 10 282 165 11.9 0 12.5 11.9 07/30/2006 17:30:00 11.8 1.5 16.4 8 11.8 1.5 16.1 8 10.1 1.8 14.5 6.5 306 9 312 165 12.3 0 12.5 12.2 07/30/2006 17:40:00 10.3 1.9 14.1 5.3 10.4 2 14.5 6.1 9.3 2.1 13 4.9 293 11 286 165 12.3 0 12.5 11.9 07/30/2006 17:50:00 12.1 2.1 16.8 5.3 12.1 2.1 16.4 5.7 10.4 2.2 15.3 4.6 305 9 302 165 12.1 0 12.2 11.9 07/30/2006 18:00:00 12.6 1.7 17.6 8.8 12.5 1.7 17.2 8.8 10.4 1.8 16.8 6.8 303 8 304 165 12.1 0 12.5 11.9 07/30/2006 18:10:00 13.5 1.6 18.7 9.5 13.3 1.6 18.3 9.5 11.5 1.6 17.2 8 306 9 305 165 12.3 0 12.7 12.2 07/30/2006 18:20:00 13.8 1.7 18.3 9.5 13.6 1.7 18.3 9.5 11.5 1.9 16.8 7.2 304 8 312 165 12 0.1 12.7 11.9 07/30/2006 18:30:00 15.6 2.1 19.9 10.3 15.5 2.1 20.2 10.3 13.2 2.5 18.7 7.6 306 7 302 165 11.8 0 11.9 11.7 07/30/2006 18:40:00 16.1 1.3 19.5 11.1 15.9 1.3 19.5 10.7 13.7 2 19.1 9.1 307 7 302 165 11.6 0 11.9 11.1 07/30/2006 18:50:00 16 1.6 21.4 11.8 15.9 1.6 21 11.8 14.1 2.2 20.6 9.1 306 7 305 165 11.3 0.1 11.7 11.1 07/30/2006 19:00:00 17.8 1.7 23.3 13.3 17.7 1.7 23.3 13 15.6 2.1 23.3 10.3 308 6 319 165 11.3 0 11.7 11.1 07/30/2006 19:10:00 18.2 1.5 22.1 14.1 18 1.5 21.8 13.7 16.4 2.2 21.8 11.1 309 6 307 165 11.3 0 11.4 10.9 07/30/2006 19:20:00 18 1.9 22.9 13 17.9 1.9 22.6 13 15.2 2.3 19.9 9.9 307 6 302 165 11.3 0.1 11.4 10.9 07/30/2006 19:30:00 18.5 2 24.4 12.2 18.3 2 24 11.1 15.4 2.3 22.9 10.7 306 6 307 165 11.3 0.1 11.4 10.9 07/30/2006 19:40:00 19 2.3 24 13.7 18.9 2.3 24 13.7 15.3 2 20.2 10.7 305 6 302 165 11.3 0 11.4 11.1 07/30/2006 19:50:00 17.3 1.5 22.1 13.7 17.2 1.5 21.8 13.7 15.2 1.9 19.9 10.3 309 7 302 165 11.2 0 11.4 11.1 07/30/2006 20:00:00 16.8 1.7 20.2 12.2 16.6 1.7 20.2 11.8 14.4 1.8 18.3 10.3 308 6 298 165 11.3 0 11.4 11.1 07/30/2006 20:10:00 16.3 1.3 19.9 11.1 16.1 1.3 19.9 11.5 14.6 1.9 19.1 9.1 311 7 313 165 11.3 0 11.4 11.1 07/30/2006 20:20:00 17.1 1.3 20.2 13.7 16.9 1.4 20.6 13 14.8 1.5 19.1 10.3 309 5 294 165 11.3 0 11.7 11.4 07/30/2006 20:30:00 16.4 1.2 19.1 13.7 16.3 1.2 19.1 13 14.1 1.6 17.6 9.1 308 5 298 165 11.3 0 11.7 11.4 07/30/2006 20:40:00 16.3 1.1 19.5 13.3 16.2 1.1 19.5 13 14.5 1.6 19.1 10.3 310 6 297 165 11.3 0 11.7 11.1 07/30/2006 20:50:00 16.9 1.5 20.6 12.6 16.7 1.6 20.2 12.2 15.5 1.7 20.6 11.5 312 6 306 165 11.3 0 11.7 11.1 07/30/2006 21:00:00 18.5 1.5 21.8 14.9 18.3 1.5 21.4 14.5 16.4 1.8 21 12.2 310 5 310 165 11.5 0 11.7 11.4 07/30/2006 21:10:00 18.8 1.5 22.6 14.1 18.6 1.5 22.6 13.7 17.6 1.7 22.1 11.8 313 6 309 165 11.5 0 11.7 11.4 07/30/2006 21:20:00 18.2 1.6 22.6 13.3 18 1.6 22.1 14.1 17.2 1.9 22.6 11.8 313 6 306 165 11.4 0 11.7 11.1 07/30/2006 21:30:00 19.9 1.7 23.7 14.9 19.7 1.7 23.3 15.3 19 1.8 22.9 14.5 313 5 314 165 11.3 0 11.7 11.1 07/30/2006 21:40:00 18.9 1.2 22.9 15.6 18.6 1.2 22.6 15.6 18.3 1.6 23.7 12.6 314 6 321 165 11.4 0.1 11.7 11.1 07/30/2006 21:50:00 19.8 1.1 22.6 15.6 19.6 1.1 22.6 15.3 19.3 1.3 22.9 14.9 314 5 319 165 11.3 0 11.4 11.1 07/30/2006 22:00:00 19.4 1.4 23.7 15.6 19.1 1.4 23.7 14.9 18.8 1.5 23.3 14.5 315 5 313 165 11.1 0 11.4 11.1 07/30/2006 22:10:00 21.1 1.5 24.4 16.8 20.9 1.5 24.4 16.1 20.7 1.7 24.4 15.6 316 5 309 165 11.2 0 11.4 11.1 07/30/2006 22:20:00 20.9 1.3 24.8 17.2 20.7 1.3 24.8 16.8 20.6 1.3 24.4 16.8 319 6 316 165 11.2 0 11.4 11.1 07/30/2006 22:30:00 20.7 1.6 24.4 16.4 20.5 1.6 24 16.1 20.2 1.7 24 14.1 317 6 315 165 11.1 0 11.4 11.1 07/30/2006 22:40:00 20.7 1.3 23.7 16.1 20.4 1.3 23.3 15.6 20.1 1.4 23.3 16.1 316 5 313 165 11.1 0 11.4 11.1 07/30/2006 22:50:00 19.9 1.1 22.9 16.8 19.7 1.1 22.6 16.4 19.7 1.3 22.9 15.3 318 5 320 165 11.1 0 11.1 10.9 07/30/2006 23:00:00 19.9 1.4 23.7 16.4 19.6 1.4 23.7 16.4 19.4 1.3 23.3 16.1 317 7 310 165 10.9 0 11.4 10.9 07/30/2006 23:10:00 18.8 1.3 22.6 15.3 18.5 1.3 22.1 15.3 18.4 1.5 22.6 14.5 317 6 314 165 10.9 0 11.1 10.9 07/30/2006 23:20:00 18.2 1.3 22.1 15.3 17.9 1.2 22.1 14.9 17.7 1.4 21.4 13.3 318 6 319 165 10.9 0.1 11.1 10.9 07/30/2006 23:30:00 19.1 1.7 23.3 13.3 18.8 1.7 22.6 14.1 18.6 1.7 22.6 14.1 320 8 318 165 10.9 0 11.1 10.6 07/30/2006 23:40:00 20 1.4 24 15.3 19.7 1.3 23.3 14.9 19.7 1.5 24 14.9 322 7 325 165 11.2 0 11.4 10.9 07/30/2006 23:50:00 20 1.3 23.3 14.9 19.7 1.3 23.7 15.3 20 1.6 24 14.9 320 6 313 165 11.3 0 11.4 11.1 07/31/2006 00:00:00 19.8 1.4 22.9 16.4 19.5 1.4 22.9 16.1 19.7 1.6 23.3 13.7 320 7 315 165 11.3 0 11.4 11.1 07/31/2006 00:10:00 18.8 1.6 23.7 14.1 18.6 1.6 23.7 13.7 18.3 1.7 25.6 13.7 315 6 323 165 11.1 0 11.4 10.9 07/31/2006 00:20:00 20 1.4 22.9 16.4 19.9 1.4 22.9 16.4 18.2 1.7 21.8 13.7 311 5 304 165 11.1 0 11.4 10.9 07/31/2006 00:30:00 19.6 1.3 22.9 16.1 19.4 1.3 22.9 15.6 18.3 1.5 22.1 14.5 313 5 307 165 11 0 11.1 10.9 07/31/2006 00:40:00 20 1.2 23.3 16.4 19.8 1.2 22.9 15.6 19.3 1.3 22.6 15.3 316 5 313 165 10.7 0.1 11.1 10.3 07/31/2006 00:50:00 20.1 1.1 22.9 17.6 19.8 1 22.6 17.2 20 1.3 23.3 16.1 319 6 320 165 10.9 0 11.1 10.6 07/31/2006 01:00:00 20.7 1.3 23.7 14.9 20.4 1.3 23.7 15.6 20.7 1.6 24 15.3 319 6 325 165 11.1 0 11.4 10.9 07/31/2006 01:10:00 20.6 1.2 23.3 15.6 20.3 1.2 22.9 15.6 20.2 1.6 24 16.1 319 6 311 165 11 0 11.4 10.9 07/31/2006 01:20:00 19.6 1.5 22.9 14.9 19.3 1.4 22.9 15.6 19.2 1.8 23.7 13.7 322 6 323 165 11.2 0.1 11.4 10.9 07/31/2006 01:30:00 19.1 1.5 23.7 14.1 18.8 1.5 23.3 14.1 18.7 1.7 23.3 14.1 322 7 326 165 11.3 0 11.7 11.1 07/31/2006 01:40:00 18.8 1.5 23.7 13.7 18.5 1.5 22.6 13.3 18.4 1.5 23.7 13 322 7 329 165 11.5 0 11.7 11.4 07/31/2006 01:50:00 18.4 1.1 21 15.3 18.1 1.1 21 15.3 17.7 1.3 20.6 13 317 6 308 165 11.3 0 11.7 10.9 07/31/2006 02:00:00 18.8 1.3 22.6 15.3 18.5 1.3 22.1 15.3 18 1.4 21.8 13.7 315 4 309 165 11.3 0.1 11.7 10.9 07/31/2006 02:10:00 18.9 1.1 21.8 15.3 18.7 1.1 21.8 15.3 18.3 1.3 21.4 14.5 315 4 316 165 11.3 0 11.7 11.1 07/31/2006 02:20:00 17.6 1.3 20.6 12.6 17.4 1.3 20.6 11.8 16.9 1.4 19.9 10.7 316 5 307 165 11.5 0 11.7 11.1 07/31/2006 02:30:00 15.5 1.4 18.7 12.2 15.3 1.4 18.7 12.2 15.2 1.5 19.1 11.5 318 7 320 165 11.3 0 11.7 11.1 07/31/2006 02:40:00 16.2 1.3 19.1 12.2 16.1 1.3 19.1 11.8 15.5 1.5 18.3 10.3 317 8 314 165 11.4 0 11.7 11.1 07/31/2006 02:50:00 16.1 1.5 19.9 12.6 16 1.5 19.9 13 15.2 1.5 19.1 9.9 315 8 302 165 11.5 0 11.7 11.1 07/31/2006 03:00:00 16.8 1.2 20.6 13.7 16.6 1.2 21 13.7 16 1.5 19.1 11.5 318 9 305 165 11.5 0 11.7 11.4 07/31/2006 03:10:00 15.8 1.3 18.7 12.6 15.7 1.3 18.3 12.2 15.2 1.7 19.1 10.3 317 8 323 165 11.5 0 11.7 11.1 07/31/2006 03:20:00 15.1 1.5 17.9 11.5 14.9 1.5 18.3 11.1 13.5 1.4 16.4 9.5 312 8 306 165 11.3 0 11.7 10.9 07/31/2006 03:30:00 14.7 1.3 17.9 11.1 14.5 1.3 17.6 11.1 14.4 1.3 17.9 10.3 322 8 310 165 11.5 0.2 11.9 11.1 07/31/2006 03:40:00 15.3 1.3 18.7 11.8 15 1.3 18.7 11.1 14.8 1.8 18.7 9.1 322 8 317 165 11.7 0.2 11.9 11.4 07/31/2006 03:50:00 17.2 1.9 21.8 12.2 17 1.8 21 12.2 17.3 1.9 21.8 12.2 323 7 325 165 11.9 0 12.2 11.7 07/31/2006 04:00:00 19.3 1.6 23.3 14.9 19 1.6 23.7 14.5 19.2 1.7 23.3 13.3 322 6 325 165 12 0 12.2 11.9 07/31/2006 04:10:00 20 1.5 24.4 16.4 19.8 1.6 24 15.6 19.8 1.8 24.8 14.9 320 7 319 165 12.1 0 12.5 11.9 07/31/2006 04:20:00 18.7 1.4 22.6 15.3 18.5 1.3 22.6 15.3 18.4 1.5 22.6 14.5 320 8 313 165 11.9 0 12.2 11.7 07/31/2006 04:30:00 17.4 1.5 20.6 13.3 17.1 1.5 21 13 17.1 1.6 21 13 324 8 312 165 11.7 0 11.9 11.4 07/31/2006 04:40:00 19.2 2.2 26 13.3 18.8 2.2 24.8 13.3 18.8 2.4 25.2 13.3 322 6 328 165 11.9 0.1 12.2 11.4 07/31/2006 04:50:00 20.8 1.6 24.8 16.1 20.5 1.6 24.4 15.3 20.5 1.8 24.8 14.9 320 6 321 165 12 0 12.2 11.9 07/31/2006 05:00:00 18 2.4 25.2 13 17.7 2.4 24.8 13 17.6 2.5 24.4 12.6 325 8 320 165 11.9 0.1 12.2 11.7 07/31/2006 05:10:00 16.3 1.6 20.2 12.6 16.1 1.5 19.9 12.6 15 1.6 19.5 10.3 313 7 313 165 11.5 0 11.7 11.1 07/31/2006 05:20:00 15.8 1.4 19.9 11.8 15.6 1.3 19.5 12.2 14.8 1.5 18.7 10.3 316 9 310 165 11.5 0 11.7 11.1 07/31/2006 05:30:00 16.7 2.2 21 10.7 16.4 2.2 21 10.7 16.2 2.2 20.2 11.1 325 7 316 165 11.5 0.2 12.2 11.1 07/31/2006 05:40:00 20 1.8 24.8 14.5 19.7 1.8 24.8 14.1 19.6 2 24.4 14.1 320 6 317 165 12.3 0.1 12.5 11.9 07/31/2006 05:50:00 22.2 1.4 25.2 17.6 21.9 1.4 25.6 17.2 21.7 1.7 26.3 16.4 317 5 303 165 12.5 0 12.7 12.5 07/31/2006 06:00:00 23.1 1.4 26 17.9 22.8 1.5 25.6 17.9 22.6 1.5 26.3 17.2 316 5 326 165 12.7 0 12.7 12.5 07/31/2006 06:10:00 23.1 1.3 29.1 19.5 22.9 1.3 28.7 19.1 22.5 1.5 28.3 19.1 315 5 310 165 12.7 0 13 12.5 07/31/2006 06:20:00 22.9 1.2 26 18.7 22.6 1.3 26 17.9 22 1.4 24.8 17.6 314 4 310 165 12.6 0 12.7 12.5 07/31/2006 06:30:00 21.7 1.6 26.3 15.6 21.5 1.6 25.6 15.3 20 1.7 24.8 14.9 312 5 305 165 12.7 0 13 12.7 07/31/2006 06:40:00 20.6 1.7 25.2 16.4 20.4 1.7 25.6 16.4 18.6 2.7 25.2 12.2 311 7 311 165 13 0.2 13.5 12.2 07/31/2006 06:50:00 20.3 1.5 25.2 15.6 20 1.5 25.6 14.9 19 2 26 13.3 313 6 315 165 12.8 0 13 12.7 07/31/2006 07:00:00 20.3 1.5 25.2 16.1 20 1.6 25.2 15.3 18.7 1.9 23.7 12.2 312 6 309 165 12.9 0.1 13.3 12.7 07/31/2006 07:10:00 18.7 1.6 24.8 14.9 18.5 1.5 24.4 14.9 17.5 1.9 23.7 12.2 313 6 321 165 12.9 0 13 12.7 07/31/2006 07:20:00 17.9 1.2 21.4 14.5 17.6 1.2 21 14.9 17.1 1.5 21.4 12.2 316 5 314 165 12.9 0 13 12.7 07/31/2006 07:30:00 16.2 1.3 19.9 13 16 1.3 19.9 12.6 15.1 1.6 20.2 11.1 314 7 316 165 12.9 0.1 13.3 12.5 07/31/2006 07:40:00 16.1 1.3 20.6 12.6 15.9 1.3 20.2 12.6 15.5 1.4 19.5 11.1 319 7 319 165 12.8 0.1 13 12.7 07/31/2006 07:50:00 14.3 1.3 18.3 9.5 14.1 1.3 17.9 9.5 14.1 1.4 17.6 9.9 320 7 322 165 13.1 0 13.3 13 07/31/2006 08:00:00 13.3 1.3 16.8 9.9 13.1 1.3 16.8 9.9 12.8 1.4 16.4 8.4 319 7 316 165 13.5 0 13.8 13.3 07/31/2006 08:10:00 13.9 1.3 17.2 11.1 13.8 1.3 16.8 10.7 13.4 1.5 17.6 9.1 317 7 317 165 13.5 0 13.8 13.3 07/31/2006 08:20:00 15.7 1.3 18.7 11.5 15.5 1.3 18.3 11.8 14.1 1.7 18.3 9.1 312 6 312 165 13.3 0 13.8 13 07/31/2006 08:30:00 15.8 0.9 18.3 13.3 15.7 1 18.3 13 14.4 1.5 18.3 10.3 312 4 311 165 13.5 0 13.8 13.3 07/31/2006 08:40:00 15 1.1 17.9 11.5 14.9 1.1 17.9 11.1 12.9 1.7 16.4 8.8 310 5 310 165 13.5 0 13.5 13.3 07/31/2006 08:50:00 14 1.5 17.2 9.9 13.9 1.5 17.2 10.3 12.4 1.7 16.4 8.4 312 9 318 165 13.9 0.1 14.1 13.5 07/31/2006 09:00:00 14.8 1 17.9 12.2 14.8 1.1 18.3 11.8 12.7 1.5 16.4 9.1 310 5 309 165 13.5 0 14.1 13.3 07/31/2006 09:10:00 14.1 1.2 17.6 11.5 14 1.2 17.2 11.5 11.9 1.5 16.8 8.8 308 6 319 165 13.3 0.1 13.5 13 07/31/2006 09:20:00 13.4 1.3 16.1 10.3 13.4 1.3 16.1 9.9 11 1.2 14.5 8 306 5 302 165 13.7 0 13.8 13.5 07/31/2006 09:30:00 13.2 1.2 16.1 9.9 13.1 1.2 16.1 9.9 11.2 1.5 15.3 8 310 8 313 165 13.9 0.1 14.4 13.5 07/31/2006 09:40:00 13.2 1.2 17.2 10.3 13.1 1.3 16.8 10.7 11.6 1.7 15.3 7.2 310 7 303 165 14.3 0 14.6 14.1 07/31/2006 09:50:00 13.8 1.3 17.6 10.7 13.8 1.3 17.2 10.3 12.1 1.4 16.8 9.1 309 5 300 165 14.3 0 14.6 14.1 07/31/2006 10:00:00 13.7 1.1 16.1 10.7 13.7 1.1 16.1 10.3 11.9 1.5 16.1 8.4 310 5 319 165 14.3 0 14.6 14.1 07/31/2006 10:10:00 15.2 1.3 18.3 10.3 15 1.3 17.9 10.3 13.7 1.7 17.9 9.5 312 4 314 165 14.5 0.2 15.2 14.1 07/31/2006 10:20:00 15.9 1.1 18.3 11.1 15.7 1.1 18.3 11.5 15.5 1.2 18.3 9.9 318 5 310 165 14.2 0 14.6 14.1 07/31/2006 10:30:00 14.7 1 17.2 10.7 14.5 1 16.8 10.7 14.5 1.2 16.8 10.7 320 5 323 165 14.7 0.1 15.2 14.6 07/31/2006 10:40:00 13.6 1.1 16.1 10.7 13.4 1.1 15.6 10.7 13.4 1.3 16.4 10.3 319 5 319 165 14.7 0.1 15.2 14.6 07/31/2006 10:50:00 14.2 1.1 16.8 10.7 13.9 1.1 16.4 10.7 13.8 1.5 16.4 9.5 320 6 324 165 14.8 0.2 15.7 14.6 07/31/2006 11:00:00 14.4 1 16.8 10.7 14.2 1 16.4 10.7 13.8 1.4 16.4 8.8 318 5 313 165 15.2 0 15.7 15.2 07/31/2006 11:10:00 13.1 1.2 16.4 8.4 13 1.2 16.4 8.8 13 1.2 16.4 9.9 322 8 332 165 15.6 0.1 16 15.5 07/31/2006 11:20:00 13.3 1.2 15.6 9.9 13.1 1.2 15.6 9.9 12.5 1.3 15.6 8.4 315 6 313 165 15 0.3 15.7 14.6 07/31/2006 11:30:00 11.6 1 13.3 8 11.5 1 13.3 7.6 10.9 1 13 8.4 315 5 318 165 14.8 0 15.5 14.6 07/31/2006 11:40:00 12 0.9 14.1 9.5 11.9 0.9 14.1 9.5 11.4 1.1 14.1 8 315 6 312 165 15 0 15.7 14.6 07/31/2006 11:50:00 11.8 1.1 14.9 8.8 11.7 1.1 14.9 8.8 10.7 1.5 13.7 6.8 313 7 305 165 14.7 0 14.9 14.6 07/31/2006 12:00:00 11.2 1.6 15.3 6.5 11.2 1.6 15.3 6.5 10.2 1.8 14.5 6.5 312 9 329 165 14.7 0 15.5 14.6 07/31/2006 12:10:00 11.6 1.2 14.1 8.8 11.5 1.2 14.1 8.4 9.7 1.3 12.6 6.8 308 6 291 165 14.7 0 14.9 14.6 07/31/2006 12:20:00 10.8 1.5 15.3 7.2 10.7 1.5 15.3 7.2 9.5 1.3 13 6.5 312 9 305 165 15.2 0.2 16 14.9 07/31/2006 12:30:00 11.7 1.4 15.3 8.8 11.7 1.4 14.9 8.8 10.4 1.7 15.3 6.8 310 6 314 165 15.3 0 15.7 14.9 07/31/2006 12:40:00 12.6 1.1 15.6 9.9 12.5 1 14.9 9.9 12.2 1.2 14.9 8.4 315 5 310 165 15 0 15.2 14.6 07/31/2006 12:50:00 11.5 1.1 14.5 8.8 11.4 1.1 14.5 8.8 10.3 1.3 14.5 7.2 311 8 299 165 14.6 0 15.2 14.6 07/31/2006 13:00:00 11.7 1.4 15.3 8.8 11.6 1.4 14.9 8.4 10.8 1.5 15.3 6.8 312 5 309 165 14.6 0.1 15.5 14.6 07/31/2006 13:10:00 11 1.1 13.3 7.6 10.9 1.1 13.3 7.2 10.1 1.3 13.7 6.5 311 5 308 165 15.2 0 15.7 15.2 07/31/2006 13:20:00 9.3 1 12.2 6.8 9.3 1 11.5 6.8 8.4 1.2 11.1 5.7 310 9 309 165 15.7 0 16 15.5 07/31/2006 13:30:00 7.8 1.1 11.5 5.3 7.9 1.1 11.1 5.7 7.2 1.3 10.3 4.6 312 7 316 165 16.4 0.3 16.8 15.7 07/31/2006 13:40:00 7.3 1.1 9.9 4.9 7.3 1.1 10.3 4.9 6.9 1.3 10.3 4.6 314 8 317 165 16.8 0.1 17.4 16.6 07/31/2006 13:50:00 6.8 1.3 9.5 3.4 6.8 1.3 9.9 3.4 6.3 1.5 9.5 3 315 12 317 165 17 0.1 17.4 16.8 07/31/2006 14:00:00 7.7 0.8 9.5 5.7 7.6 0.8 9.5 5.3 7.1 1 9.1 4.6 314 8 304 165 16.3 0.1 16.8 16 07/31/2006 14:10:00 6.5 0.7 8.8 4.9 6.4 0.7 8.8 4.9 6.2 0.8 8.8 4.2 316 10 306 165 16.4 0.2 16.8 16 07/31/2006 14:20:00 7.4 0.9 9.5 4.6 7.3 0.9 9.5 4.6 7.1 0.8 9.1 5.3 318 9 319 165 17.1 0.2 17.7 16.8 07/31/2006 14:30:00 9.2 1 11.1 6.5 9.1 1.1 11.1 6.5 9 1.2 11.1 5.7 316 5 320 165 16.4 0.6 17.7 15.5 07/31/2006 14:40:00 8.3 1.1 11.8 6.1 8.3 1.2 11.5 6.1 7.2 1.1 10.3 4.2 306 12 294 165 15.7 0 16.3 15.5 07/31/2006 14:50:00 9 1 11.5 6.8 9.1 1 11.1 6.5 7.4 0.9 9.9 5.3 304 6 297 165 15.2 0.1 15.7 15.2 07/31/2006 15:00:00 6.8 1.2 10.7 4.6 6.8 1.2 10.3 3.8 6.1 1.3 10.7 3.4 313 12 323 165 15.5 0.3 16.3 15.2 07/31/2006 15:10:00 8.2 0.9 10.3 6.1 8.1 0.9 9.9 6.1 7.9 1.1 9.9 4.9 313 5 313 165 15.9 0 16.3 15.7 07/31/2006 15:20:00 7.4 1.1 9.9 4.6 7.3 1.1 10.3 4.6 6.4 0.9 9.1 4.6 307 9 292 165 17 0.7 18.2 16 07/31/2006 15:30:00 8.9 1.1 12.2 6.5 8.9 1.1 12.2 6.5 7.5 1.2 11.5 4.6 305 9 295 165 17.5 0.4 18.5 16.8 07/31/2006 15:40:00 8.3 1 11.1 6.1 8.2 1 11.1 6.1 7.8 1.2 11.1 5.3 315 8 310 165 16.8 0.3 17.7 16.3 07/31/2006 15:50:00 9.4 1.3 12.6 5.7 9.4 1.3 12.6 6.1 8.7 1.5 12.6 4.2 314 8 310 165 17.5 0.2 18.2 16.8 07/31/2006 16:00:00 8.2 1 10.7 5.7 8.1 0.9 10.7 6.1 8 1.1 10.7 4.9 323 12 296 165 16.9 0 17.1 16.8 07/31/2006 16:10:00 8 0.7 10.3 6.1 7.9 0.7 10.3 5.7 7.3 0.8 9.5 4.6 314 10 294 165 15.9 0.3 16.8 15.7 07/31/2006 16:20:00 8 0.6 9.9 6.5 7.9 0.7 9.5 6.5 7.7 0.7 10.7 6.1 316 5 323 165 15.4 0 16 15.2 07/31/2006 16:30:00 7.2 0.9 9.5 4.9 7.1 0.8 9.1 5.3 7.1 1 8.8 4.6 318 5 313 165 15.5 0 15.7 15.5 07/31/2006 16:40:00 6 0.8 7.6 3.8 5.9 0.8 8 3.8 5.6 0.9 7.6 3.4 316 10 317 165 15.6 0 15.7 15.5 07/31/2006 16:50:00 6.2 0.7 7.6 4.2 6.1 0.7 7.6 4.2 5.9 0.8 8 4.2 317 6 326 165 15.6 0 15.7 15.7 07/31/2006 17:00:00 6.4 0.6 8 4.9 6.3 0.5 8 4.9 6.3 0.6 8 4.2 315 5 318 165 15.9 0 16.3 15.7 07/31/2006 17:10:00 6.4 0.6 7.6 4.6 6.3 0.6 7.6 4.2 6.1 0.7 7.6 3.8 314 6 319 165 15.9 0 16.3 15.7 07/31/2006 17:20:00 6.4 0.6 7.6 4.6 6.3 0.6 7.6 4.6 5.5 0.9 7.6 3.4 306 7 318 165 15.7 0 16 15.7 07/31/2006 17:30:00 6.2 1 8.4 3.4 6.2 1 8.4 3.4 5.2 0.9 8.4 3 303 8 304 165 15.5 0 15.7 15.5 07/31/2006 17:40:00 5.7 0.8 8 3.4 5.7 0.8 8.4 3.8 4.6 0.8 7.2 3.4 301 6 305 165 15.2 0 15.7 15.2 07/31/2006 17:50:00 6.1 0.9 9.1 3.8 6.2 0.9 8.8 4.2 5 0.8 7.6 3 303 6 301 165 15.2 0 15.5 15.2 07/31/2006 18:00:00 5.3 0.8 6.5 2.6 5.3 0.8 6.8 2.6 4.8 1 6.8 3 300 11 300 165 15.1 0 15.5 14.9 07/31/2006 18:10:00 6 1.2 8.4 3.8 6 1.2 8.8 3.4 4.9 0.8 7.2 3 298 9 303 165 14.9 0 15.2 14.9 07/31/2006 18:20:00 6.3 0.8 8.8 4.6 6.3 0.8 8.8 4.6 5.4 1 8.4 3.4 306 5 308 165 14.8 0 15.2 14.6 07/31/2006 18:30:00 6.5 0.8 8 4.2 6.5 0.8 8 4.2 5.4 0.7 7.2 3 305 5 300 165 14.6 0.1 14.9 14.6 07/31/2006 18:40:00 6.2 0.7 7.6 4.2 6.1 0.7 7.6 4.2 5.8 0.8 7.6 3.8 312 6 313 165 14.6 0 14.9 14.6 07/31/2006 18:50:00 7.5 0.6 8.8 4.9 7.5 0.6 8.8 5.3 7 0.7 8.4 4.9 311 5 311 165 14.6 0 14.9 14.6 07/31/2006 19:00:00 7.7 0.7 9.9 6.5 7.6 0.6 9.9 6.5 7.1 0.8 9.1 4.9 312 5 311 165 14.8 0 14.9 14.6 07/31/2006 19:10:00 9.3 0.8 11.5 6.8 9.2 0.8 11.5 6.8 8 1 10.7 5.3 309 5 305 165 14.6 0 14.9 14.6 07/31/2006 19:20:00 10.7 0.6 12.6 9.1 10.6 0.6 12.6 9.1 8.6 0.9 11.5 6.5 307 4 304 165 14.7 0 14.9 14.6 07/31/2006 19:30:00 11 0.6 12.6 9.1 11 0.6 12.2 8.8 9.6 1.1 12.6 6.8 310 6 310 165 13.9 0.1 14.9 13.5 07/31/2006 19:40:00 10.5 0.8 12.6 8 10.4 0.8 13 8 9.8 0.9 12.2 6.5 312 6 310 165 13.5 0 13.8 13.3 07/31/2006 19:50:00 10.5 0.9 12.6 8 10.5 0.9 12.6 7.6 8.8 0.9 11.1 6.1 307 5 307 165 13.3 0 13.8 13 07/31/2006 20:00:00 10.2 0.8 13 8.4 10.2 0.8 13.3 8 8.4 1 11.5 5.7 304 6 315 165 13.1 0 13.3 13 07/31/2006 20:10:00 10.1 0.9 12.6 7.2 10.1 0.9 12.6 7.2 7.7 0.8 10.3 5.7 300 5 299 165 13.1 0 13.5 13 07/31/2006 20:20:00 8.2 1.2 11.1 5.3 8.2 1.1 10.7 5.3 6.5 1.1 9.5 3 299 6 301 165 13.3 0 13.5 13 07/31/2006 20:30:00 7.2 0.9 9.5 5.3 7.2 0.8 9.1 4.9 6 0.9 8 3.4 292 6 299 165 12.9 0 13 12.7 07/31/2006 20:40:00 9.7 1.1 12.6 7.2 9.7 1.1 12.2 7.2 7.4 0.9 11.1 5.3 298 5 299 165 12.7 0 12.7 12.5 07/31/2006 20:50:00 9.9 0.9 11.8 6.8 9.9 1 11.8 7.2 7.6 1 10.7 4.9 302 5 301 165 12.7 0 12.7 12.5 07/31/2006 21:00:00 10.4 0.7 12.6 7.6 10.5 0.7 11.8 7.6 7.6 0.9 11.5 5.3 300 4 301 165 12.7 0 12.7 12.7 07/31/2006 21:10:00 9.6 0.9 11.8 7.6 9.7 0.9 11.8 7.6 7.3 0.8 9.5 4.9 300 5 297 165 12.7 0 13 12.5 07/31/2006 21:20:00 8.4 0.7 9.9 6.1 8.4 0.7 10.3 6.1 6.3 0.7 8.8 4.6 301 5 297 165 12.7 0 12.7 12.5 07/31/2006 21:30:00 8.8 0.8 10.7 6.8 8.8 0.8 10.7 6.8 6.9 0.9 9.9 4.6 304 5 301 165 12.6 0 12.7 12.5 07/31/2006 21:40:00 8.4 0.6 9.9 6.8 8.4 0.6 9.9 6.8 7 0.7 8.8 5.3 307 4 300 165 12.5 0 12.7 12.5 07/31/2006 21:50:00 8.1 0.6 9.5 6.5 8.1 0.7 9.5 6.5 6.3 0.7 8.4 4.6 304 5 298 165 12.6 0 13 12.5 07/31/2006 22:00:00 8.5 0.6 9.5 6.1 8.5 0.6 9.9 6.5 6.3 0.6 8 4.9 302 4 301 165 12.6 0 12.7 12.5 07/31/2006 22:10:00 10.2 1.3 14.1 6.5 10.2 1.3 13.3 6.5 7.8 1.4 11.1 4.6 301 6 302 165 12.6 0 12.7 12.5 07/31/2006 22:20:00 8.4 1.5 11.8 4.6 8.4 1.5 11.5 4.6 8 1.5 11.5 3.8 314 5 309 165 12.4 0 12.5 12.2 07/31/2006 22:30:00 6 0.8 8.8 3 6 0.8 8.8 3.4 5 0.9 8 3 299 10 300 165 12.2 0 12.5 11.7 07/31/2006 22:40:00 4.7 1 6.8 1.9 4.8 1.1 7.2 1.5 4.4 0.8 7.2 2.6 306 17 297 165 12.3 0.1 12.5 11.7 07/31/2006 22:50:00 5.7 1.3 9.1 3 5.7 1.3 9.1 3 5.1 0.9 8 2.6 310 13 297 165 12.3 0 12.5 11.7 07/31/2006 23:00:00 6.7 0.7 8.8 4.9 6.7 0.7 8.8 4.9 5.5 0.7 7.6 3.8 299 9 298 165 11.9 0 12.2 11.7 07/31/2006 23:10:00 7.2 0.6 9.1 5.7 7.3 0.6 9.1 5.7 5.6 0.8 8.4 4.2 298 5 299 165 11.8 0 11.9 11.7 07/31/2006 23:20:00 7.3 0.5 8.8 5.7 7.4 0.4 9.1 6.1 6 0.8 8.4 4.2 300 7 287 165 11.7 0 11.9 11.7 07/31/2006 23:30:00 6.8 0.6 8.4 5.7 6.9 0.5 8.4 5.7 5.8 0.7 7.6 4.2 306 5 299 165 11.7 0 11.9 11.7 07/31/2006 23:40:00 6.5 0.6 7.6 4.6 6.6 0.6 8 4.9 5.2 0.7 7.2 3.4 300 6 295 165 11.8 0 11.9 11.7 07/31/2006 23:50:00 6.6 0.7 9.1 4.9 6.7 0.7 8.8 4.9 5.4 0.9 8.4 3.8 292 5 291 165 11.8 0 11.9 11.7 08/01/2006 00:00:00 7 0.8 8.8 5.3 7.1 0.8 9.1 5.3 5.5 0.9 8.4 3.8 293 5 289 165 11.7 0 11.9 11.4 08/01/2006 00:10:00 6.8 0.7 8.4 5.3 6.9 0.7 8.8 5.3 5.4 0.8 7.6 3.8 292 5 299 165 11.6 0 11.7 11.4 08/01/2006 00:20:00 6.3 0.7 8.4 4.6 6.5 0.7 8.4 4.6 4.9 0.8 8 3.4 294 5 296 165 11.6 0 11.7 11.4 08/01/2006 00:30:00 7 0.8 9.1 4.9 7.1 0.8 9.5 5.3 5.5 0.8 7.6 3.8 298 6 301 165 11.4 0 11.7 11.4 08/01/2006 00:40:00 6.9 0.6 8.8 5.3 6.9 0.6 8.8 5.3 5.3 0.6 8.8 3.8 299 5 300 165 11.3 0 11.7 11.4 08/01/2006 00:50:00 7.2 0.7 8.8 4.6 7.3 0.7 8.8 4.9 5.7 0.8 8.4 3.8 296 6 294 165 11.5 0 11.7 11.4 08/01/2006 01:00:00 6.5 0.7 8 4.6 6.5 0.7 8.4 4.6 5.2 0.8 7.6 3 293 6 293 165 11.4 0 11.7 11.4 08/01/2006 01:10:00 6 0.7 7.6 4.2 6.1 0.7 7.6 4.2 4.8 0.7 6.8 3 293 6 295 165 11.5 0 11.7 11.4 08/01/2006 01:20:00 4.7 0.7 7.2 3 4.7 0.7 7.2 3 3.8 0.6 5.7 2.3 296 7 281 165 11.6 0 11.7 11.4 08/01/2006 01:30:00 5.9 1.1 8.4 3.8 6 1.1 8.4 3.4 5.3 1.2 8 3 288 7 282 165 11.5 0 11.7 11.4 08/01/2006 01:40:00 6.3 1.1 8.4 3 6.3 1.1 8.4 3 5.7 1.4 8.4 2.6 288 7 282 165 11.2 0 11.4 10.9 08/01/2006 01:50:00 5.2 0.8 6.8 3.4 5.3 0.8 7.2 3.4 4.4 1 6.8 2.3 294 8 292 165 11 0.1 11.4 10.6 08/01/2006 02:00:00 6 0.8 7.6 3.8 6.1 0.8 7.6 3.8 5.3 1.1 7.6 3 290 7 282 165 11 0.1 11.4 10.6 08/01/2006 02:10:00 5.2 0.7 6.8 3 5.3 0.7 6.8 3 4.4 0.9 6.5 2.3 291 6 291 165 11 0.2 11.4 10.6 08/01/2006 02:20:00 4.5 0.7 6.1 2.6 4.6 0.7 6.1 2.6 4.1 0.9 6.1 2.3 289 6 287 165 11.2 0.1 11.4 10.9 08/01/2006 02:30:00 3.6 0.6 4.9 1.9 3.7 0.6 4.9 2.3 3.3 0.5 4.6 2.3 290 10 287 165 11.4 0 11.7 11.1 08/01/2006 02:40:00 2.5 0.5 3.8 1.1 2.6 0.5 3.8 0.7 2.7 0.5 3.8 1.1 289 13 298 165 11.3 0 11.7 11.1 08/01/2006 02:50:00 1.3 0.7 3.4 0.4 1.3 0.7 3 0.4 1.4 0.6 3 0.4 296 11 310 165 10.9 0 11.1 10.6 08/01/2006 03:00:00 2.2 1.9 5.3 0.4 2.3 1.9 5.3 0.4 2.1 1.7 5.3 0.4 264 24 289 165 10.9 0 11.1 10.6 08/01/2006 03:10:00 5.4 0.5 6.5 4.2 5.4 0.5 6.5 4.2 4.2 0.5 6.1 3 297 5 302 165 11 0 11.4 10.9 08/01/2006 03:20:00 5.5 0.4 6.5 4.6 5.5 0.4 6.5 4.2 4.2 0.6 5.7 3 295 5 297 165 10.9 0 11.1 10.9 08/01/2006 03:30:00 5.4 0.4 6.5 4.2 5.4 0.5 6.8 4.2 5.2 0.7 6.8 3 285 5 279 165 11.1 0 11.4 10.9 08/01/2006 03:40:00 5.2 0.5 6.5 3.8 5.3 0.5 6.5 3.8 4 0.6 5.7 2.6 295 5 299 165 10.9 0 11.1 10.6 08/01/2006 03:50:00 5.3 0.4 6.5 4.6 5.4 0.5 6.8 4.6 4.6 0.9 6.5 3 292 5 289 165 10.7 0.1 11.1 10.6 08/01/2006 04:00:00 5.5 0.4 6.5 4.2 5.6 0.5 6.5 4.2 4.6 0.8 6.5 2.6 292 4 294 165 10.7 0.1 10.9 10.3 08/01/2006 04:10:00 4.8 0.4 6.1 3.8 4.8 0.5 6.1 3.4 3.7 0.5 5.3 2.6 295 4 295 165 10.5 0.1 10.9 10.1 08/01/2006 04:20:00 4 0.4 4.9 3 4 0.4 4.9 3 3.2 0.4 4.6 2.3 301 5 304 165 10.7 0.2 11.1 10.3 08/01/2006 04:30:00 4.1 0.4 4.9 2.6 4.1 0.4 4.9 2.6 3.2 0.5 4.9 1.9 298 5 305 165 10.7 0.1 10.9 10.3 08/01/2006 04:40:00 3.9 0.4 4.9 2.6 3.9 0.5 4.9 2.6 3 0.5 4.9 1.9 296 5 294 165 10.7 0.1 11.1 10.3 08/01/2006 04:50:00 3.5 0.4 4.2 2.3 3.6 0.4 4.2 2.3 3 0.5 4.2 1.5 293 6 294 165 10.7 0.1 11.1 10.3 08/01/2006 05:00:00 3.4 0.4 4.2 2.3 3.5 0.4 4.6 2.3 3.4 0.6 4.6 1.9 287 6 293 165 10.7 0.1 11.1 10.3 08/01/2006 05:10:00 2.9 0.6 4.2 1.5 3.2 0.5 4.6 1.9 3.2 0.6 4.6 1.5 278 7 290 165 10.6 0.1 10.9 10.1 08/01/2006 05:20:00 2.8 0.4 3.8 1.9 2.9 0.4 3.8 1.9 2.7 0.4 3.8 1.5 294 11 314 165 10.4 0 10.9 9.8 08/01/2006 05:30:00 2.1 0.5 3.4 0.7 2.2 0.5 3.4 0.7 2.2 0.4 3.4 1.1 309 5 310 165 10.3 0.1 10.9 9.8 08/01/2006 05:40:00 1.3 0.4 2.3 0.4 1.4 0.4 2.3 0.7 1.6 0.3 2.3 0.7 298 6 307 165 10.3 0.1 10.6 9.8 08/01/2006 05:50:00 0.8 0.2 1.1 0.4 0.7 0.3 1.5 0.4 1.6 0.2 1.9 1.1 311 10 300 165 10.2 0.2 10.6 9.6 08/01/2006 06:00:00 0.4 0 0.7 0.4 0.4 0 0.4 0.4 1.1 0.2 1.5 0.7 329 2 326 165 10.2 0 10.6 9.6 08/01/2006 06:10:00 0.4 0.2 1.5 0.4 0.4 0.2 1.9 0.4 1.1 0.2 1.9 0.7 324 9 307 165 10.3 0.1 10.6 9.6 08/01/2006 06:20:00 1.5 0.4 2.3 0.4 1.6 0.5 2.6 0.4 1.5 0.3 2.3 0.7 300 4 299 165 10.2 0.2 10.9 9.6 08/01/2006 06:30:00 2.3 0.3 3 1.5 2.4 0.3 3 1.9 2 0.3 2.6 1.1 293 5 289 165 10.5 0.2 10.9 10.1 08/01/2006 06:40:00 2 0.4 2.6 1.1 2.1 0.4 3 1.1 1.9 0.5 3.4 1.1 287 4 280 165 10.7 0.1 11.1 10.6 08/01/2006 06:50:00 3 0.3 3.8 2.3 3.1 0.3 3.8 2.3 3.1 0.3 3.8 2.3 281 3 278 165 10.7 0 11.1 10.6 08/01/2006 07:00:00 3.3 0.4 4.2 1.9 3.4 0.4 4.2 1.9 3.4 0.4 4.6 2.3 280 5 279 165 10.7 0 10.9 10.6 08/01/2006 07:10:00 3.1 0.5 4.2 1.5 3.2 0.5 4.2 1.9 3.3 0.5 4.2 1.5 283 6 277 165 10.5 0.2 10.9 10.3 08/01/2006 07:20:00 2.2 0.5 3.4 1.1 2.5 0.5 3.8 1.5 2.9 0.4 3.8 1.9 277 5 275 165 10.4 0.1 10.9 10.3 08/01/2006 07:30:00 1.3 0.5 2.6 0.4 1.5 0.5 2.6 0.4 2.1 0.6 3.4 0.7 281 8 282 165 10.3 0 10.6 10.1 08/01/2006 07:40:00 0.7 0.3 1.5 0.4 0.6 0.3 1.5 0.4 1.1 0.3 1.9 0.4 308 7 296 165 10.5 0.2 10.9 10.1 08/01/2006 07:50:00 1.2 0.3 1.9 0.7 1.2 0.4 1.9 0.4 1.6 0.4 2.6 0.7 307 7 307 165 10.3 0 10.9 9.8 08/01/2006 08:00:00 0.8 0.4 1.9 0.4 0.7 0.5 1.9 0.4 1 0.4 1.9 0.4 286 13 292 165 10.2 0 10.6 9.8 08/01/2006 08:10:00 0.4 0.1 0.7 0.4 0.4 0 0.4 0.4 0.6 0.2 1.1 0.4 290 17 257 165 10.1 0.1 10.3 9.6 08/01/2006 08:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.7 0.2 1.1 0.4 300 2 165 165 10.3 0 10.6 9.6 08/01/2006 08:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0.2 0.7 0.4 300 2 165 165 10.5 0 10.6 10.3 08/01/2006 08:40:00 0.7 0.5 1.9 0.4 0.7 0.5 1.9 0.4 1 0.6 1.9 0.4 282 13 268 165 10.2 0 10.6 9.8 08/01/2006 08:50:00 2.1 0.5 3.4 1.1 2.2 0.6 3.4 1.1 2.5 0.6 4.2 1.5 278 9 280 165 10 0.1 10.3 9.6 08/01/2006 09:00:00 1.8 0.5 2.6 0.7 1.7 0.5 3 0.7 1.7 0.3 2.6 0.7 296 5 291 165 9.6 0.2 10.1 9 08/01/2006 09:10:00 0.9 0.3 1.9 0.4 0.6 0.3 1.5 0.4 1.2 0.4 2.3 0.4 289 10 279 165 9.5 0 9.6 9 08/01/2006 09:20:00 0.4 0.2 1.5 0.4 0.4 0.2 1.5 0.4 0.7 0.5 2.3 0.4 220 38 252 165 9.4 0 9.6 8.8 08/01/2006 09:30:00 0.6 0.4 1.5 0.4 0.5 0.2 1.1 0.4 1 0.3 1.9 0.4 180 10 172 165 9.4 0.2 9.6 8.8 08/01/2006 09:40:00 0.6 0.3 1.9 0.4 0.5 0.2 1.5 0.4 1.2 0.4 2.3 0.4 168 5 172 165 9.6 0.1 9.8 9 08/01/2006 09:50:00 0.4 0 0.7 0.4 0.4 0 0.4 0.4 0.4 0.2 1.5 0.4 161 6 165 165 9.6 0 9.8 9.3 08/01/2006 10:00:00 0.8 0.4 1.9 0.4 0.6 0.4 1.9 0.4 1 0.4 2.3 0.4 122 17 121 165 9.4 0.1 9.8 9 08/01/2006 10:10:00 0.8 0.4 1.9 0.4 0.8 0.4 1.5 0.4 1.1 0.4 1.9 0.4 103 10 124 165 9.5 0.1 9.6 9 08/01/2006 10:20:00 0.9 0.4 1.9 0.4 0.9 0.4 1.9 0.4 1.4 0.4 2.3 0.4 119 14 115 165 9.5 0.2 9.8 9 08/01/2006 10:30:00 1.4 0.5 2.6 0.4 1.3 0.6 2.3 0.4 1.7 0.3 2.3 1.1 120 13 116 165 9.5 0 9.6 9 08/01/2006 10:40:00 1.7 0.4 2.6 0.4 1.6 0.5 2.6 0.4 2.1 0.3 2.6 1.1 143 10 151 165 9.4 0 9.6 9 08/01/2006 10:50:00 2.1 0.4 3 1.5 2 0.4 3 1.1 2.5 0.3 3 1.5 153 7 148 165 9.3 0 9.3 9 08/01/2006 11:00:00 1.5 0.6 3 0.4 1.4 0.6 3 0.4 1.9 0.4 2.6 1.1 162 4 159 165 9.3 0 9.3 9 08/01/2006 11:10:00 0.9 0.5 2.6 0.4 0.7 0.5 2.3 0.4 1.5 0.3 2.3 0.7 167 3 166 165 9.4 0 9.6 9 08/01/2006 11:20:00 2.1 0.3 3 1.1 2 0.3 2.6 1.1 2.3 0.3 3 1.5 170 4 169 165 9.4 0 9.6 9 08/01/2006 11:30:00 1.7 0.4 2.6 0.7 1.7 0.4 2.3 0.7 2.3 0.3 3 1.5 166 5 167 165 9.4 0 9.6 9 08/01/2006 11:40:00 1.9 0.3 2.6 1.1 1.8 0.3 2.6 1.1 2.4 0.3 3 1.9 163 3 163 165 9.2 0 9.6 9 08/01/2006 11:50:00 2.4 0.4 3.8 1.5 2.4 0.4 3.4 1.5 2.7 0.3 3.4 2.3 160 5 160 165 9.4 0 9.6 9 08/01/2006 12:00:00 2.9 0.3 3.8 1.9 2.8 0.3 3.8 1.9 3.1 0.3 3.8 2.6 161 4 157 165 9.4 0 9.6 9.3 08/01/2006 12:10:00 2.7 0.3 3.8 1.9 2.6 0.3 3.4 1.9 3 0.3 3.8 2.3 157 5 150 165 9.5 0.2 9.8 9 08/01/2006 12:20:00 2.9 0.5 3.8 1.1 2.8 0.5 3.8 1.1 3.2 0.5 4.6 1.9 158 9 159 165 9.5 0.2 9.8 9 08/01/2006 12:30:00 2.4 0.4 3.4 1.5 2.3 0.4 3.4 1.1 2.7 0.4 3.8 1.5 161 8 158 165 9.4 0.2 9.6 8.8 08/01/2006 12:40:00 2.4 0.5 3.4 1.1 2.3 0.4 3 1.1 2.6 0.4 3.4 1.5 155 8 158 165 9.4 0.2 9.8 9 08/01/2006 12:50:00 1.9 0.4 3 1.1 1.8 0.5 2.6 0.7 2.3 0.4 3 1.5 147 11 154 165 9.7 0 10.1 9.3 08/01/2006 13:00:00 2.5 0.5 3.4 1.1 2.4 0.5 3.4 0.7 2.7 0.4 3.4 1.9 139 8 136 165 10 0 10.3 9.8 08/01/2006 13:10:00 3.1 0.6 4.2 0.7 3 0.7 4.2 1.1 3.3 0.6 4.6 1.9 142 9 150 165 10.1 0 10.3 9.8 08/01/2006 13:20:00 2.7 0.6 4.2 1.5 2.7 0.6 3.8 1.1 2.9 0.5 4.2 1.5 137 9 145 165 10 0 10.3 9.8 08/01/2006 13:30:00 2.4 0.4 3.4 1.1 2.4 0.4 3.4 0.7 2.7 0.3 3.4 1.9 137 9 143 165 10.3 0 10.6 10.1 08/01/2006 13:40:00 2.2 0.4 3 1.1 2.1 0.5 3 0.7 2.5 0.4 3.4 1.5 148 8 162 165 10.3 0 10.6 10.3 08/01/2006 13:50:00 1.8 0.4 2.6 0.7 1.6 0.4 2.6 0.4 2.2 0.3 3 1.1 155 6 165 165 10.5 0 10.6 10.3 08/01/2006 14:00:00 2.8 0.4 3.8 1.9 2.7 0.5 3.8 1.5 3.1 0.3 4.2 2.3 142 8 134 165 10.5 0 10.9 10.3 08/01/2006 14:10:00 3.4 0.3 4.2 2.6 3.3 0.3 3.8 2.6 3.5 0.3 4.2 2.6 140 5 147 165 10.4 0 10.9 10.3 08/01/2006 14:20:00 3.9 0.3 4.6 3 3.9 0.3 4.6 3 4 0.3 4.6 3 136 4 130 165 10.5 0 10.9 10.3 08/01/2006 14:30:00 4.2 0.3 4.9 3 4.2 0.4 4.9 3 4.3 0.3 5.3 3.4 139 4 141 165 10.4 0 10.9 10.3 08/01/2006 14:40:00 4.1 0.3 4.9 3 4.1 0.3 4.9 2.6 4.2 0.3 4.9 3.4 139 5 135 165 10.2 0 10.6 10.3 08/01/2006 14:50:00 4.1 0.3 4.9 3 4.1 0.3 4.6 3 4.3 0.3 4.9 3.4 136 4 136 165 10.1 0 10.3 9.8 08/01/2006 15:00:00 4.1 0.3 4.6 3 4.1 0.4 4.6 3 4.2 0.3 4.9 3 132 6 131 165 9.9 0 10.3 9.6 08/01/2006 15:10:00 4 0.3 4.9 3.4 4 0.3 4.6 3 4.1 0.3 4.9 3.4 131 5 121 165 10.2 0 10.6 9.8 08/01/2006 15:20:00 3.9 0.4 4.9 2.6 3.8 0.4 4.9 2.6 4 0.4 4.9 3 136 7 135 165 10.3 0 10.6 10.3 08/01/2006 15:30:00 4.2 0.4 4.9 2.6 4.2 0.4 5.3 3 4.4 0.4 5.3 3 140 6 128 165 10.5 0 10.9 10.1 08/01/2006 15:40:00 4.4 0.5 5.7 3 4.4 0.5 5.7 3 4.6 0.4 6.1 3.4 140 7 134 165 10.3 0.1 10.6 10.1 08/01/2006 15:50:00 4.1 0.5 5.7 3 4.1 0.5 5.7 2.6 4.3 0.5 5.7 3 137 7 133 165 10.2 0 10.6 10.1 08/01/2006 16:00:00 3.7 0.4 4.9 2.6 3.7 0.4 4.9 2.3 3.8 0.4 4.6 2.6 135 10 130 165 10.5 0.1 10.9 9.8 08/01/2006 16:10:00 3.7 0.5 4.9 2.3 3.7 0.5 4.9 2.3 3.9 0.5 5.3 2.6 131 7 138 165 10.7 0.1 10.9 10.6 08/01/2006 16:20:00 3.6 0.5 4.9 2.6 3.6 0.5 5.3 2.3 3.8 0.4 5.3 2.6 130 9 125 165 10.8 0 11.1 10.6 08/01/2006 16:30:00 2.8 0.5 4.2 1.5 2.8 0.6 4.6 1.1 3 0.6 4.6 1.9 127 9 118 165 10.7 0 10.9 10.6 08/01/2006 16:40:00 2.7 0.4 3.8 1.5 2.7 0.5 3.8 1.1 2.9 0.4 3.8 1.9 124 8 121 165 10.9 0 11.1 10.9 08/01/2006 16:50:00 2.7 0.5 3.8 1.5 2.6 0.5 4.2 1.5 2.9 0.4 3.8 2.3 131 11 143 165 10.7 0 11.1 10.6 08/01/2006 17:00:00 2.3 0.4 3.4 1.1 2.1 0.5 3.4 0.4 2.7 0.3 3.8 1.9 136 10 136 165 10.7 0.1 10.9 10.3 08/01/2006 17:10:00 2.7 0.5 4.2 1.9 2.7 0.5 4.2 1.5 3.2 0.5 4.2 2.3 140 9 135 165 10.7 0 10.9 10.3 08/01/2006 17:20:00 2.2 0.5 3.4 0.7 2.1 0.6 3.8 0.4 2.6 0.5 3.8 1.5 126 7 121 165 10.6 0 10.9 9.8 08/01/2006 17:30:00 1.5 0.6 2.6 0.4 1.3 0.6 2.6 0.4 1.9 0.4 3 0.7 119 11 116 165 10.7 0.1 10.9 10.6 08/01/2006 17:40:00 1 0.6 3 0.4 0.8 0.6 3 0.4 1.6 0.5 3 0.4 116 20 135 165 10.9 0 11.1 10.9 08/01/2006 17:50:00 0.9 0.4 1.9 0.4 0.6 0.4 1.9 0.4 1.5 0.4 2.6 0.7 115 17 96 165 10.9 0 11.1 10.6 08/01/2006 18:00:00 0.6 0.3 1.9 0.4 0.4 0.2 1.5 0.4 0.9 0.5 1.9 0.4 89 15 81 165 10.9 0 11.1 10.6 08/01/2006 18:10:00 1.4 0.4 2.3 0.4 1.2 0.6 2.3 0.4 1.9 0.4 2.6 0.7 109 7 115 165 11 0 11.1 10.6 08/01/2006 18:20:00 0.5 0.2 1.5 0.4 0.4 0.1 1.1 0.4 0.9 0.4 1.9 0.4 102 6 99 165 11.1 0 11.1 10.9 08/01/2006 18:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0.1 1.1 0.4 105 2 165 165 11.1 0 11.4 10.9 08/01/2006 18:40:00 0.9 0.5 2.3 0.4 0.6 0.4 1.9 0.4 1.1 0.6 2.6 0.4 49 23 36 165 11.2 0 11.4 10.9 08/01/2006 18:50:00 1.7 0.4 2.6 0.7 1.4 0.5 2.6 0.4 2.2 0.4 3 1.1 28 10 37 165 11.1 0 11.4 10.9 08/01/2006 19:00:00 0.8 0.4 1.9 0.4 0.5 0.3 1.5 0.4 1.2 0.5 2.6 0.4 22 14 15 165 11.1 0 11.1 11.1 08/01/2006 19:10:00 0.4 0.2 1.1 0.4 0.4 0 0.4 0.4 0.6 0.3 1.5 0.4 15 15 4 165 11.1 0 11.1 10.9 08/01/2006 19:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.7 0.4 42 1 165 165 11 0 11.1 10.9 08/01/2006 19:30:00 0.4 0.2 1.5 0.4 0.4 0.1 1.1 0.4 0.4 0.1 1.1 0.4 115 35 117 165 11 0 11.1 10.6 08/01/2006 19:40:00 0.4 0.1 1.1 0.4 0.4 0 0.4 0.4 0.4 0 0.7 0.4 120 17 95 165 11 0 11.1 10.6 08/01/2006 19:50:00 0.6 0.3 1.5 0.4 0.4 0.1 1.1 0.4 1 0.5 1.9 0.4 73 35 28 165 10.9 0 11.1 10.9 08/01/2006 20:00:00 0.7 0.3 1.1 0.4 0.4 0.1 1.1 0.4 1.1 0.2 1.9 0.7 31 6 35 165 10.8 0 11.1 10.9 08/01/2006 20:10:00 0.9 0.2 1.1 0.4 0.5 0.2 1.1 0.4 1.4 0.2 1.9 1.1 28 1 29 165 10.7 0 10.9 10.6 08/01/2006 20:20:00 0.5 0.2 1.1 0.4 0.4 0 0.7 0.4 0.9 0.3 1.5 0.4 61 23 74 165 10.7 0.1 10.9 10.3 08/01/2006 20:30:00 0.6 0.3 1.5 0.4 0.4 0 0.7 0.4 1.2 0.3 1.9 0.4 34 17 18 165 10.7 0 10.9 10.3 08/01/2006 20:40:00 1 0.4 1.9 0.4 0.7 0.4 1.9 0.4 1.3 0.3 2.3 0.4 52 24 81 165 10.4 0.1 10.9 10.1 08/01/2006 20:50:00 1.4 0.4 1.9 0.4 1.2 0.4 1.9 0.4 1.5 0.4 2.3 0.4 112 11 99 165 10.5 0.3 10.9 9.8 08/01/2006 21:00:00 0.7 0.6 2.3 0.4 0.7 0.5 1.9 0.4 0.7 0.5 2.3 0.4 112 2 114 165 10.7 0.1 10.9 10.3 08/01/2006 21:10:00 1.7 0.6 2.6 0.4 1.6 0.7 2.6 0.4 1.6 0.8 2.6 0.4 116 5 114 165 10.3 0.1 10.6 9.8 08/01/2006 21:20:00 1.6 0.3 2.6 0.7 1.5 0.4 2.6 0.7 1.7 0.3 2.3 1.1 125 7 125 165 10.3 0.1 10.6 9.8 08/01/2006 21:30:00 1 0.2 1.5 0.4 0.9 0.3 1.9 0.4 1.7 0.2 2.3 1.1 107 6 115 165 10.3 0.2 10.6 9.8 08/01/2006 21:40:00 1.8 0.5 2.6 1.1 1.9 0.6 3 0.7 2.2 0.4 3 1.5 107 3 110 165 10.3 0 10.6 9.8 08/01/2006 21:50:00 1.5 0.4 2.6 0.7 1.4 0.4 2.6 0.4 2 0.4 3 1.1 116 10 112 165 10.3 0 10.6 9.6 08/01/2006 22:00:00 0.7 0.5 1.9 0.4 0.6 0.4 1.9 0.4 1.3 0.5 2.3 0.4 122 10 128 165 10.4 0 10.6 9.8 08/01/2006 22:10:00 0.8 0.5 1.9 0.4 0.7 0.4 1.9 0.4 1 0.6 2.3 0.4 120 15 111 165 10.3 0.1 10.6 9.8 08/01/2006 22:20:00 0.5 0.3 2.3 0.4 0.4 0.2 2.3 0.4 0.8 0.5 2.3 0.4 130 23 145 165 10.4 0 10.6 9.8 08/01/2006 22:30:00 0.5 0.3 1.5 0.4 0.4 0.1 1.1 0.4 0.8 0.4 1.9 0.4 137 17 138 165 10.5 0 10.9 9.8 08/01/2006 22:40:00 0.7 0.5 2.3 0.4 0.6 0.4 1.9 0.4 1.1 0.6 2.3 0.4 145 14 153 165 10.7 0.2 10.9 10.1 08/01/2006 22:50:00 0.4 0 1.1 0.4 0.4 0 0.4 0.4 0.4 0.2 1.1 0.4 152 0 153 165 10.6 0 10.9 10.3 08/01/2006 23:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 152 2 165 165 10.4 0 10.6 9.6 08/01/2006 23:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 8 38 165 165 10.3 0 10.6 9.6 08/01/2006 23:20:00 0.4 0.1 1.1 0.4 0.4 0 0.4 0.4 0.5 0.3 1.5 0.4 91 56 126 165 10.2 0 10.6 9.8 08/01/2006 23:30:00 0.4 0.2 1.1 0.4 0.4 0 0.4 0.4 0.5 0.2 1.5 0.4 168 41 224 165 10.1 0.1 10.3 9.6 08/01/2006 23:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0.1 0.7 0.4 225 0 165 165 10.4 0 10.6 9.8 08/01/2006 23:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 225 0 165 165 10.4 0 10.6 10.1 08/02/2006 00:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 225 1 165 165 10.4 0 10.9 10.1 08/02/2006 00:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 196 5 165 165 10.2 0.1 10.6 9.8 08/02/2006 00:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 194 1 165 165 10.1 0.2 10.3 9.6 08/02/2006 00:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 193 2 165 165 10 0.2 10.3 9.6 08/02/2006 00:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 191 1 165 165 10 0.1 10.3 9.6 08/02/2006 00:50:00 0.4 0.1 1.1 0.4 0.4 0 0.4 0.4 0.4 0.1 1.1 0.4 203 17 218 165 10.1 0.1 10.3 9.6 08/02/2006 01:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 245 2 165 165 10.1 0.1 10.3 9.6 08/02/2006 01:10:00 0.4 0.1 0.7 0.4 0.4 0 0.4 0.4 0.4 0.2 1.1 0.4 248 3 246 165 10.1 0.1 10.3 9.6 08/02/2006 01:20:00 0.4 0.1 0.7 0.4 0.4 0 0.4 0.4 0.4 0.1 0.7 0.4 253 1 253 165 10.1 0.1 10.3 9.6 08/02/2006 01:30:00 0.4 0.1 1.1 0.4 0.4 0 0.4 0.4 0.4 0.2 1.5 0.4 232 24 219 165 10.1 0.1 10.3 9.6 08/02/2006 01:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 181 3 165 165 10 0.1 10.3 9.6 08/02/2006 01:50:00 0.6 0.3 1.1 0.4 0.4 0.1 1.1 0.4 0.6 0.3 1.5 0.4 261 22 266 165 10.1 0.1 10.3 9.6 08/02/2006 02:00:00 0.5 0.2 1.1 0.4 0.4 0.1 0.7 0.4 0.9 0.5 1.9 0.4 315 18 326 165 10 0 10.3 9.3 08/02/2006 02:10:00 1.4 0.4 2.3 0.7 0.4 0.2 1.1 0.4 2 0.3 2.6 1.5 358 2 358 165 10 0 10.1 9.3 08/02/2006 02:20:00 1.5 0.3 2.3 0.7 0.5 0.2 1.1 0.4 2.2 0.2 2.6 1.9 1 4 2 165 9.9 0 10.1 9.3 08/02/2006 02:30:00 0.7 0.3 1.5 0.4 0.4 0.1 1.1 0.4 1.3 0.4 2.3 0.7 330 12 355 165 9.9 0 10.3 9.3 08/02/2006 02:40:00 0.4 0.1 0.7 0.4 0.4 0 0.4 0.4 1.1 0.2 1.5 0.7 317 0 317 165 9.9 0 10.3 9.3 08/02/2006 02:50:00 0.9 0.4 1.5 0.4 0.7 0.4 1.5 0.4 1.6 0.4 2.3 0.7 331 12 332 165 9.9 0 10.1 9.3 08/02/2006 03:00:00 0.9 0.2 1.5 0.4 0.5 0.2 1.1 0.4 1.6 0.2 2.3 1.1 356 4 350 165 9.9 0 10.1 9 08/02/2006 03:10:00 0.4 0.1 0.7 0.4 0.4 0 0.4 0.4 0.9 0.2 1.5 0.4 359 0 358 165 9.8 0 10.1 9.3 08/02/2006 03:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.5 0.2 1.1 0.4 359 0 165 165 9.8 0.1 9.8 9.3 08/02/2006 03:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.6 0.3 1.5 0.4 359 0 165 165 9.8 0 9.8 9 08/02/2006 03:40:00 1.2 0.9 3.4 0.4 1.2 0.8 3.4 0.4 1.1 0.7 2.6 0.4 313 30 306 165 9.9 0 10.1 9.3 08/02/2006 03:50:00 2.5 0.9 4.6 1.1 2.4 0.9 4.2 1.1 2.1 0.6 4.2 0.7 298 7 294 165 10 0 10.3 9.6 08/02/2006 04:00:00 4.4 0.7 5.7 3 4.3 0.7 5.7 2.6 3.3 0.5 4.9 1.9 297 5 296 165 10 0 10.3 9.3 08/02/2006 04:10:00 4.7 0.4 5.7 3.4 4.7 0.4 5.7 3.4 3.8 0.5 5.3 2.6 303 7 307 165 10 0 10.1 9.3 08/02/2006 04:20:00 5 0.7 6.8 2.6 5 0.7 6.8 3 4.3 0.6 5.7 2.6 306 7 301 165 10 0 10.3 9.3 08/02/2006 04:30:00 4.9 0.5 6.1 3.4 4.9 0.5 6.5 3.8 4.2 0.5 6.1 3 306 6 296 165 10.1 0 10.6 9.8 08/02/2006 04:40:00 4.6 0.6 6.1 3 4.6 0.6 5.7 3 3.7 0.5 5.3 2.6 302 8 300 165 10.1 0.1 10.6 9.6 08/02/2006 04:50:00 4.1 0.8 5.7 1.9 4.1 0.8 5.7 2.3 3.7 0.8 6.1 1.5 310 9 310 165 10.1 0.1 10.3 9.6 08/02/2006 05:00:00 5.3 0.7 6.8 3.4 5.3 0.7 6.8 3.4 4.3 0.6 6.1 2.6 307 5 313 165 10.1 0.1 10.3 9.6 08/02/2006 05:10:00 4.9 0.7 6.8 3.4 4.9 0.7 6.8 3.4 3.9 0.6 5.7 2.6 301 6 292 165 10.1 0.1 10.3 9.6 08/02/2006 05:20:00 5.8 0.5 7.2 4.6 5.7 0.5 6.8 4.6 4.4 0.6 6.5 2.6 298 4 296 165 10.1 0.1 10.3 9.6 08/02/2006 05:30:00 5 0.6 6.8 3.4 5 0.6 6.5 3.4 3.8 0.5 5.3 2.6 303 5 300 165 10.1 0 10.3 9.6 08/02/2006 05:40:00 4.3 0.6 6.1 2.6 4.4 0.6 5.7 2.6 4 0.6 5.7 2.3 311 7 304 165 10.1 0.1 10.6 9.6 08/02/2006 05:50:00 3.5 0.6 4.6 2.3 3.5 0.6 4.9 1.9 3 0.6 4.6 1.9 299 8 304 165 10.1 0.1 10.3 9.6 08/02/2006 06:00:00 3.2 0.6 5.3 1.9 3.3 0.6 5.3 1.9 2.7 0.6 4.6 1.1 297 8 294 165 10.2 0 10.6 9.8 08/02/2006 06:10:00 3.9 0.8 6.1 2.3 3.9 0.7 6.1 2.3 3.3 0.7 5.3 1.5 304 7 308 165 10.2 0 10.6 9.6 08/02/2006 06:20:00 4.4 0.8 6.5 2.3 4.4 0.7 6.5 2.6 3.9 0.7 5.7 2.3 308 8 310 165 10.3 0 10.6 9.8 08/02/2006 06:30:00 4.7 0.6 6.8 2.3 4.6 0.6 6.5 2.3 3.9 0.6 5.7 2.3 307 8 312 165 10.3 0 10.6 9.8 08/02/2006 06:40:00 3 0.8 4.9 1.5 3 0.8 5.3 1.5 2.9 0.7 4.9 1.9 312 8 313 165 10.7 0.1 10.9 9.8 08/02/2006 06:50:00 0.9 0.6 2.6 0.4 0.8 0.6 2.6 0.4 1.1 0.6 2.6 0.4 332 20 311 165 10.8 0.1 11.1 10.3 08/02/2006 07:00:00 0.4 0.2 1.5 0.4 0.4 0.1 1.1 0.4 0.6 0.3 1.5 0.4 311 43 17 165 11 0.1 11.4 10.6 08/02/2006 07:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0.2 1.5 0.4 329 66 165 165 11.3 0.1 11.7 10.6 08/02/2006 07:20:00 0.5 0.2 1.1 0.4 0.4 0.1 1.1 0.4 0.7 0.4 1.5 0.4 207 11 208 165 11.3 0.1 11.7 10.9 08/02/2006 07:30:00 0.5 0.2 1.1 0.4 0.5 0.2 1.1 0.4 0.8 0.4 1.9 0.4 260 24 285 165 11.4 0 11.7 10.9 08/02/2006 07:40:00 0.7 0.5 1.9 0.4 0.7 0.4 1.9 0.4 1.2 0.5 2.3 0.4 162 12 165 165 11.1 0.3 11.7 10.6 08/02/2006 07:50:00 0.6 0.4 1.5 0.4 0.6 0.4 1.5 0.4 0.8 0.5 1.9 0.4 198 32 211 165 10.9 0 11.1 10.6 08/02/2006 08:00:00 0.5 0.3 1.5 0.4 0.5 0.3 1.5 0.4 0.9 0.5 2.3 0.4 153 13 153 165 10.9 0 11.1 10.9 08/02/2006 08:10:00 0.4 0.2 1.9 0.4 0.4 0.2 1.5 0.4 0.5 0.3 1.5 0.4 170 43 213 165 10.8 0 11.1 10.9 08/02/2006 08:20:00 0.4 0 0.7 0.4 0.4 0.1 1.1 0.4 0.6 0.4 1.9 0.4 142 13 94 165 11 0 11.1 10.9 08/02/2006 08:30:00 0.4 0.1 1.1 0.4 0.4 0.1 1.1 0.4 0.8 0.5 2.3 0.4 137 30 194 165 11.1 0 11.4 10.9 08/02/2006 08:40:00 0.5 0.3 1.5 0.4 0.5 0.3 1.9 0.4 0.8 0.5 2.3 0.4 151 32 127 165 11.3 0 11.4 11.1 08/02/2006 08:50:00 0.5 0.3 1.9 0.4 0.4 0.2 1.5 0.4 0.9 0.4 1.9 0.4 141 27 165 165 11.2 0 11.4 10.9 08/02/2006 09:00:00 0.4 0.2 1.1 0.4 0.4 0.1 1.1 0.4 0.7 0.5 1.9 0.4 146 56 164 165 11.1 0 11.4 10.9 08/02/2006 09:10:00 0.8 0.6 2.3 0.4 0.8 0.6 2.3 0.4 1.1 0.7 2.6 0.4 135 41 145 165 11.3 0 11.4 11.1 08/02/2006 09:20:00 0.6 0.4 1.9 0.4 0.5 0.3 1.5 0.4 0.9 0.5 1.9 0.4 171 27 161 165 11.1 0 11.4 10.9 08/02/2006 09:30:00 1.4 0.6 2.6 0.4 1.3 0.6 2.6 0.4 1.9 0.6 2.6 0.4 141 32 118 165 11.5 0 11.7 11.1 08/02/2006 09:40:00 0.7 0.5 2.6 0.4 0.6 0.5 2.3 0.4 0.9 0.6 2.3 0.4 128 82 326 165 11.5 0 11.7 11.1 08/02/2006 09:50:00 0.9 0.4 1.9 0.4 0.7 0.4 1.9 0.4 1.1 0.5 2.3 0.4 27 20 360 165 12.1 0.1 12.5 11.7 08/02/2006 10:00:00 1.3 0.8 3 0.4 1.1 0.7 3 0.4 1.2 0.8 3 0.4 20 24 2 165 12.4 0 12.5 12.2 08/02/2006 10:10:00 0.5 0.4 1.9 0.4 0.5 0.3 2.3 0.4 0.5 0.4 1.9 0.4 62 22 6 165 12.3 0 12.5 12.2 08/02/2006 10:20:00 0.5 0.4 1.9 0.4 0.4 0.2 1.1 0.4 0.6 0.4 1.9 0.4 88 26 92 165 12 0 12.2 11.9 08/02/2006 10:30:00 1 0.4 2.3 0.4 0.9 0.5 2.6 0.4 1.4 0.5 2.3 0.4 102 21 107 165 12 0 12.2 11.9 08/02/2006 10:40:00 0.6 0.4 2.3 0.4 0.5 0.4 2.3 0.4 1 0.5 2.3 0.4 104 28 115 165 11.7 0 12.2 11.7 08/02/2006 10:50:00 0.9 0.4 1.9 0.4 0.7 0.4 1.9 0.4 1.3 0.4 2.3 0.4 107 26 92 165 11.5 0 11.7 11.4 08/02/2006 11:00:00 0.8 0.6 2.6 0.4 0.7 0.5 2.3 0.4 1.3 0.7 3 0.4 98 17 128 165 11.7 0.1 11.9 11.4 08/02/2006 11:10:00 1.9 0.5 3 0.7 1.7 0.6 3.4 0.4 2.1 0.5 3.4 0.7 134 16 148 165 12.1 0 12.5 11.9 08/02/2006 11:20:00 1.7 0.5 2.6 0.4 1.6 0.5 2.6 0.4 2 0.4 3 0.7 128 9 117 165 12.1 0 12.5 11.9 08/02/2006 11:30:00 1.6 0.6 3 0.4 1.6 0.6 3 0.4 2.1 0.5 3 0.7 144 13 163 165 11.9 0 12.2 11.7 08/02/2006 11:40:00 1.6 0.6 3 0.4 1.6 0.7 3 0.4 1.9 0.6 3.4 0.4 137 11 144 165 12 0 12.5 11.9 08/02/2006 11:50:00 2.5 0.5 3.8 1.5 2.4 0.5 3.4 1.1 2.8 0.4 3.8 1.9 144 8 137 165 12 0.2 12.5 11.7 08/02/2006 12:00:00 2.5 0.5 3.8 0.4 2.6 0.4 4.2 1.1 2.8 0.4 3.8 1.9 138 11 151 165 11.6 0 11.9 11.4 08/02/2006 12:10:00 2 0.6 3.8 0.7 1.9 0.7 4.2 0.4 2.5 0.5 4.2 1.5 144 11 136 165 11.9 0 12.2 11.7 08/02/2006 12:20:00 2.9 0.5 4.2 1.5 2.8 0.5 4.2 1.1 3.3 0.4 4.2 2.6 155 8 154 165 11.9 0 12.2 11.7 08/02/2006 12:30:00 3.4 0.4 4.6 2.3 3.3 0.4 4.6 2.3 3.6 0.4 4.6 2.3 147 6 136 165 11.6 0 11.9 11.4 08/02/2006 12:40:00 3.3 0.5 4.6 2.3 3.2 0.5 4.2 1.9 3.5 0.4 4.6 2.3 145 7 145 165 11.7 0 11.9 11.4 08/02/2006 12:50:00 3 0.4 3.8 2.3 2.8 0.4 3.8 1.9 3.2 0.4 4.6 1.9 141 9 134 165 11.9 0 12.2 11.7 08/02/2006 13:00:00 3.9 0.7 5.3 2.3 3.8 0.7 5.7 2.3 4.1 0.6 5.7 2.6 145 8 140 165 12.7 0.2 13 12.2 08/02/2006 13:10:00 4.4 0.4 5.3 3 4.3 0.4 4.9 3 4.5 0.5 5.7 2.6 142 6 146 165 12.3 0 12.7 11.9 08/02/2006 13:20:00 4.1 0.4 5.3 2.6 4.1 0.4 4.9 3 4.3 0.4 5.3 3.4 140 5 138 165 12.5 0 12.7 12.5 08/02/2006 13:30:00 4 0.6 5.3 2.3 4 0.5 5.3 2.3 4.2 0.5 5.7 2.6 135 9 141 165 13 0.4 13.5 12.5 08/02/2006 13:40:00 3.1 0.6 4.9 1.1 3.2 0.6 5.3 1.1 3.5 0.5 5.3 1.9 132 13 139 165 13.5 0 13.8 13.3 08/02/2006 13:50:00 4.7 0.7 6.1 2.6 4.7 0.7 6.1 3 5.1 0.6 6.5 3.4 144 8 132 165 13.7 0.2 14.6 13.3 08/02/2006 14:00:00 5.4 0.4 6.5 3.8 5.4 0.4 6.5 3.8 5.5 0.4 6.5 3.8 136 5 157 165 13.7 0 14.1 13.3 08/02/2006 14:10:00 5.3 0.5 6.8 3.8 5.3 0.5 7.2 4.2 5.4 0.5 6.8 4.2 135 5 141 165 13.7 0 14.1 13.5 08/02/2006 14:20:00 4.9 0.4 6.1 3.8 4.8 0.4 5.7 3.8 5.1 0.4 6.5 3.8 139 5 135 165 13.4 0.3 13.8 12.7 08/02/2006 14:30:00 5.1 0.4 6.1 3.8 5.1 0.4 6.1 4.2 5.3 0.4 6.5 4.2 138 6 138 165 12.6 0.2 13.3 12.2 08/02/2006 14:40:00 4.5 0.4 6.1 3.4 4.4 0.4 6.1 3.4 4.8 0.4 6.1 3.4 138 6 141 165 12.9 0.2 13.5 12.5 08/02/2006 14:50:00 4.2 0.5 5.7 3 4.3 0.5 6.1 3 4.5 0.5 5.7 3.4 136 7 134 165 13.7 0 14.4 13.3 08/02/2006 15:00:00 4.6 0.4 5.7 3 4.7 0.4 5.7 3.4 4.8 0.4 6.1 3.8 131 6 138 165 13.5 0.3 14.1 12.7 08/02/2006 15:10:00 4.5 0.4 5.7 3.4 4.6 0.4 5.7 3 4.6 0.4 5.3 3.4 129 7 133 165 12.4 0.1 13 12.2 08/02/2006 15:20:00 4.6 0.5 6.1 3.4 4.7 0.5 6.1 3.4 4.7 0.4 5.7 3.8 129 6 145 165 13 0.2 13.3 12.5 08/02/2006 15:30:00 4.6 0.4 5.7 3.4 4.7 0.4 5.7 3 4.7 0.4 5.7 3.4 123 5 132 165 13.1 0.1 13.5 12.7 08/02/2006 15:40:00 4.2 0.6 5.7 2.6 4.3 0.6 5.7 2.6 4.3 0.6 6.1 2.6 125 8 128 165 13.1 0.3 13.8 12.7 08/02/2006 15:50:00 3.4 0.6 4.9 1.5 3.5 0.6 5.3 1.9 3.6 0.6 5.3 2.3 132 11 132 165 13.1 0.1 13.8 12.7 08/02/2006 16:00:00 3.6 0.6 4.9 1.9 3.6 0.6 5.3 1.5 3.7 0.5 5.3 2.3 133 11 136 165 13.2 0 13.5 13 08/02/2006 16:10:00 3.2 0.5 4.6 1.9 3.3 0.5 4.6 1.9 3.4 0.5 4.9 1.9 134 11 118 165 13.3 0 13.5 13 08/02/2006 16:20:00 3.3 0.5 4.6 1.5 3.4 0.5 4.9 2.3 3.6 0.5 4.9 2.3 122 9 119 165 13.2 0.1 13.5 12.7 08/02/2006 16:30:00 3.2 0.6 4.6 1.9 3.3 0.6 4.9 1.9 3.3 0.6 4.6 1.9 120 8 117 165 12.6 0.1 13 12.5 08/02/2006 16:40:00 3.7 0.5 4.9 1.9 3.8 0.5 5.3 1.9 3.7 0.5 4.9 2.3 118 7 114 165 12.4 0 12.5 12.2 08/02/2006 16:50:00 4.2 0.5 5.3 2.6 4.3 0.6 5.7 3 4.2 0.6 5.7 2.6 122 7 118 165 12.5 0 12.7 12.5 08/02/2006 17:00:00 3.9 0.8 6.1 2.3 4 0.8 6.1 2.3 4 0.7 6.1 2.6 130 9 128 165 12.6 0 12.7 12.5 08/02/2006 17:10:00 4.9 0.6 6.1 3 5 0.6 6.5 3.4 4.9 0.7 6.5 2.6 125 6 132 165 12.5 0 12.7 12.2 08/02/2006 17:20:00 4.4 0.4 5.7 3.4 4.5 0.4 5.7 3.4 4.4 0.5 5.7 3 120 6 115 165 12 0.1 12.5 11.7 08/02/2006 17:30:00 4 0.4 5.7 3 4.1 0.4 5.7 3 4.2 0.4 5.7 3 123 7 121 165 12.6 0 12.7 12.2 08/02/2006 17:40:00 4.7 0.5 6.1 3.8 4.8 0.5 6.1 3.8 4.9 0.5 6.1 3.4 126 6 125 165 12.5 0.1 12.7 12.2 08/02/2006 17:50:00 5.2 0.6 6.8 3 5.2 0.6 6.8 3.4 5.2 0.6 6.5 3.8 116 7 115 165 11.8 0.1 12.2 11.7 08/02/2006 18:00:00 5.3 0.6 6.8 3.4 5.4 0.6 6.8 3.4 5.2 0.6 6.8 3 114 7 126 165 12 0 12.2 11.9 08/02/2006 18:10:00 6.2 0.7 7.6 4.2 6.3 0.6 7.6 4.6 6.2 0.6 8 4.6 120 6 115 165 11.9 0 12.2 11.7 08/02/2006 18:20:00 6.5 0.5 8 5.3 6.7 0.5 8 5.7 6.5 0.6 8 4.9 123 5 125 165 11.3 0.2 11.9 10.9 08/02/2006 18:30:00 6.4 0.6 8 4.9 6.5 0.6 8.4 4.9 6.3 0.6 8.4 4.6 127 5 132 165 10.9 0 11.1 10.9 08/02/2006 18:40:00 6.9 0.7 8.8 4.9 7 0.7 9.1 5.3 6.8 0.8 8.8 4.6 128 6 135 165 10.7 0 11.1 10.6 08/02/2006 18:50:00 6.4 0.6 7.6 4.9 6.5 0.6 8 4.9 6.5 0.6 8.4 4.9 129 6 132 165 10.5 0 10.9 10.3 08/02/2006 19:00:00 6.2 0.5 7.6 4.9 6.4 0.5 8 4.9 6.1 0.6 8 4.6 122 6 135 165 10.2 0 10.6 9.8 08/02/2006 19:10:00 6.4 0.6 8 4.9 6.5 0.6 8 5.3 6.3 0.7 7.6 4.6 119 6 111 165 10.1 0.1 10.3 9.6 08/02/2006 19:20:00 7.1 0.6 8.8 5.3 7.2 0.6 8.8 5.7 7 0.6 8.4 4.9 124 8 135 165 10.1 0 10.3 9.8 08/02/2006 19:30:00 7.2 0.7 9.1 5.3 7.3 0.7 9.1 5.3 7.2 0.6 8.8 5.3 126 6 122 165 10.1 0 10.3 10.1 08/02/2006 19:40:00 8.6 0.9 10.7 6.1 8.7 0.9 10.7 5.7 8.6 0.9 11.5 6.1 136 5 136 165 10.1 0 10.3 9.3 08/02/2006 19:50:00 8.7 0.7 11.1 6.8 8.8 0.7 11.1 6.5 8.6 0.8 10.7 6.1 138 6 135 165 10 0 10.3 9.3 08/02/2006 20:00:00 8.4 0.6 9.9 6.8 8.5 0.7 9.9 6.8 8.4 0.7 9.9 6.5 141 5 144 165 10 0 10.3 9.6 08/02/2006 20:10:00 9.5 0.7 11.1 7.2 9.7 0.7 11.1 7.2 9.5 0.8 11.5 7.2 142 3 143 165 9.9 0 10.1 9.8 08/02/2006 20:20:00 9.2 0.6 10.7 7.6 9.4 0.6 11.1 7.6 9.2 0.7 11.1 7.2 142 4 145 165 9.8 0 10.1 9.6 08/02/2006 20:30:00 9.1 0.6 10.3 7.6 9.2 0.6 10.7 7.6 9.1 0.7 10.7 6.8 146 4 145 165 9.9 0 10.1 9.8 08/02/2006 20:40:00 9.4 0.6 10.7 7.6 9.5 0.6 11.1 8 9.5 0.7 11.5 6.8 148 4 160 165 9.9 0 10.1 9.8 08/02/2006 20:50:00 9.1 0.8 11.1 7.2 9.2 0.8 11.1 7.2 9.1 0.9 11.1 6.8 147 4 151 165 10 0 10.1 9.8 08/02/2006 21:00:00 8.8 0.6 10.7 7.2 8.9 0.6 11.1 7.2 8.9 0.6 11.1 7.2 147 5 136 165 10 0 10.3 9.8 08/02/2006 21:10:00 7.3 0.8 9.1 5.7 7.4 0.8 9.1 5.7 7.3 0.8 9.1 5.7 150 7 137 165 10 0 10.3 9.8 08/02/2006 21:20:00 6.1 0.6 7.2 4.6 6.2 0.6 7.2 4.9 6.2 0.6 7.6 4.6 145 6 145 165 10 0 10.3 9.8 08/02/2006 21:30:00 7.8 0.9 10.3 6.1 8 0.9 10.3 6.1 7.9 0.8 9.9 6.1 139 7 138 165 10.1 0 10.3 9.8 08/02/2006 21:40:00 9.2 0.7 10.7 6.8 9.3 0.7 10.7 6.8 9.2 0.8 10.7 6.8 139 5 140 165 10.4 0 10.6 10.3 08/02/2006 21:50:00 10.1 0.8 11.8 7.6 10.1 0.8 11.8 8 10.1 0.8 12.2 7.2 138 6 144 165 10.3 0 10.6 10.3 08/02/2006 22:00:00 9.2 0.8 11.5 7.6 9.2 0.8 11.5 7.6 9.1 0.9 11.8 6.8 140 4 141 165 10.2 0 10.6 10.3 08/02/2006 22:10:00 8.8 0.8 10.3 6.5 8.9 0.8 10.7 5.7 8.8 0.9 11.1 5.3 139 6 137 165 10.3 0 10.6 10.3 08/02/2006 22:20:00 9.9 1.2 12.6 6.8 10 1.2 13 6.8 9.8 1.3 13 5.7 138 6 143 165 10.4 0 10.6 10.3 08/02/2006 22:30:00 10.7 1 13.3 7.6 10.7 1 13 8 10.7 1 12.6 8.4 139 6 139 165 10.4 0 10.6 10.3 08/02/2006 22:40:00 9.4 0.7 11.1 7.6 9.5 0.7 11.1 7.6 9.4 0.8 11.1 6.8 142 6 143 165 10.2 0 10.6 10.3 08/02/2006 22:50:00 9.5 0.7 11.5 7.2 9.5 0.7 11.1 7.2 9.7 0.8 11.5 6.8 143 5 145 165 10.1 0 10.3 10.1 08/02/2006 23:00:00 9.4 1 11.8 6.8 9.5 0.9 11.8 6.8 9.3 1 12.2 6.5 141 7 145 165 10.1 0 10.3 9.8 08/02/2006 23:10:00 10.3 1.1 12.2 6.8 10.3 1 12.2 6.5 10.1 1.3 12.2 5.7 141 5 139 165 10.1 0 10.3 10.1 08/02/2006 23:20:00 11.2 0.7 13 8.8 11.1 0.7 13 8.8 11 0.9 13 8 143 5 147 165 10.2 0 10.6 10.1 08/02/2006 23:30:00 10.8 0.8 12.6 8.8 10.8 0.8 12.2 8.8 10.6 1 12.6 8.4 150 5 145 165 10.2 0 10.6 10.1 08/02/2006 23:40:00 8.9 0.5 10.3 7.2 8.8 0.5 10.3 7.2 8.8 0.6 10.3 6.1 149 3 148 165 10.3 0 10.6 10.1 08/02/2006 23:50:00 8.9 0.5 10.3 7.6 8.9 0.5 9.9 7.6 9 0.6 10.7 7.6 146 5 146 165 10.2 0 10.6 10.1 08/03/2006 00:00:00 9 0.9 11.1 6.5 9.1 0.9 11.5 6.5 8.9 1 11.5 6.1 139 6 133 165 10.1 0 10.3 9.8 08/03/2006 00:10:00 9.6 1 11.8 7.2 9.7 1 11.8 7.2 9.6 0.9 11.8 6.8 139 7 139 165 10.1 0.1 10.3 9.8 08/03/2006 00:20:00 10.1 0.9 12.6 8 10.2 0.9 13 8 9.9 1 12.6 7.6 138 6 142 165 10.1 0.1 10.3 9.6 08/03/2006 00:30:00 10.5 0.9 12.6 7.6 10.5 0.9 12.6 8.4 10.3 1 12.6 7.6 140 6 151 165 10.1 0.2 10.3 9.6 08/03/2006 00:40:00 10.3 0.8 11.8 7.6 10.3 0.8 12.2 7.6 10.2 0.9 12.2 8 141 6 136 165 10 0.2 10.3 9.6 08/03/2006 00:50:00 10.4 1 13 8 10.5 0.9 13.3 8 10.2 1 13 7.2 142 7 151 165 10 0.2 10.3 9.6 08/03/2006 01:00:00 10.1 0.8 12.2 8 10.2 0.8 12.6 7.6 10 0.8 11.8 7.6 138 7 137 165 10 0.1 10.3 9.6 08/03/2006 01:10:00 10.5 1.2 13.7 7.2 10.6 1.2 13.7 7.6 10.3 1.2 13.7 7.2 134 7 132 165 9.8 0.1 10.1 9.3 08/03/2006 01:20:00 11.1 1 14.1 8 11.2 1 14.1 8.4 11.1 1.1 13.7 7.6 138 6 130 165 9.8 0 10.1 9.3 08/03/2006 01:30:00 12.4 1.5 16.1 8.4 12.5 1.5 15.6 8.8 12.1 1.5 15.3 8.4 138 6 133 165 9.8 0 10.1 9.6 08/03/2006 01:40:00 12.4 0.9 14.5 9.1 12.4 0.9 14.5 9.9 12.1 1 14.5 8.4 135 6 142 165 9.8 0 10.1 9.6 08/03/2006 01:50:00 11.6 1.3 14.9 8 11.7 1.4 15.6 8 11.4 1.5 16.4 7.6 136 7 136 165 9.8 0 9.8 9.6 08/03/2006 02:00:00 12.4 1.2 14.9 9.1 12.5 1.3 15.3 9.1 12 1.4 15.3 7.6 135 8 135 165 9.8 0 10.1 9.3 08/03/2006 02:10:00 12.3 1.3 16.1 8.4 12.4 1.3 16.4 8.8 12.2 1.3 15.6 8 133 7 128 165 9.7 0.1 9.8 9.3 08/03/2006 02:20:00 12.3 1.2 15.3 9.1 12.5 1.2 15.3 9.5 12.1 1.3 15.6 8.8 129 7 140 165 9.7 0.1 9.8 9.3 08/03/2006 02:30:00 12.6 1.2 15.3 9.1 12.8 1.3 15.6 9.5 12.5 1.4 16.1 8 129 6 124 165 9.7 0.1 9.8 9.3 08/03/2006 02:40:00 12.6 1.2 14.9 8 12.7 1.3 15.6 8.4 12.3 1.3 15.6 8.4 130 7 139 165 9.7 0 9.8 9.6 08/03/2006 02:50:00 12.6 1.2 15.6 10.3 12.8 1.2 16.1 9.9 12.5 1.2 16.1 9.1 128 6 121 165 9.7 0 9.8 9.6 08/03/2006 03:00:00 12.1 1.2 16.8 8 12.2 1.2 16.8 8 11.5 1.4 16.1 8 130 7 128 165 9.8 0 9.8 9.6 08/03/2006 03:10:00 13.1 1.5 16.8 9.5 13.3 1.5 16.8 9.1 12.9 1.4 16.4 8.8 128 6 111 165 9.6 0 9.8 9.6 08/03/2006 03:20:00 13.1 1.5 17.9 9.1 13.3 1.5 18.3 8.8 12.8 1.7 16.8 6.8 126 7 108 165 9.6 0 9.8 9.6 08/03/2006 03:30:00 13.1 1.5 17.2 8.4 13.3 1.5 17.6 9.5 12.8 1.5 18.3 8.4 121 6 119 165 9.7 0 10.1 9.6 08/03/2006 03:40:00 13.1 1.3 16.1 9.9 13.3 1.3 16.1 9.5 12.6 1.2 15.3 9.5 122 7 110 165 9.8 0 9.8 9.3 08/03/2006 03:50:00 13.7 1.3 17.6 9.9 14 1.4 17.6 10.3 13.2 1.4 16.8 9.1 121 7 119 165 9.8 0 9.8 9.6 08/03/2006 04:00:00 13.8 1.4 16.8 8.8 14.1 1.5 17.2 8.4 13.5 1.6 16.8 8.8 125 7 126 165 9.9 0 10.1 9.6 08/03/2006 04:10:00 14.8 1.8 19.1 10.3 15 1.8 19.5 10.7 14.2 1.7 18.3 10.3 125 7 127 165 10 0 10.1 9.6 08/03/2006 04:20:00 15.1 1.3 18.3 11.1 15.3 1.3 18.3 11.1 14.7 1.4 18.7 10.3 126 6 135 165 10 0 10.1 9.8 08/03/2006 04:30:00 15.7 1.7 21 11.8 15.9 1.7 21.4 11.8 15.4 1.9 20.6 11.1 125 7 122 165 10 0 10.1 9.6 08/03/2006 04:40:00 15.8 1.6 20.2 11.8 16.1 1.6 20.6 11.8 15.5 1.7 21 10.3 125 7 121 165 10 0 10.1 9.8 08/03/2006 04:50:00 15.9 1.7 19.9 11.5 16.2 1.7 20.2 10.7 15.6 1.9 21.4 9.9 127 7 119 165 10 0 10.3 9.6 08/03/2006 05:00:00 15.4 2.1 21 9.9 15.6 2.1 21 10.3 14.9 2.2 20.6 9.5 128 8 116 165 10 0 10.3 9.8 08/03/2006 05:10:00 15.9 2.1 20.6 10.3 16 2.1 20.6 10.3 15.3 2.2 20.6 9.9 128 8 135 165 10 0 10.3 9.3 08/03/2006 05:20:00 15.3 1.6 19.9 10.7 15.5 1.7 20.2 11.8 14.8 1.7 19.5 10.7 129 8 117 165 10 0 10.3 9.8 08/03/2006 05:30:00 14.5 1.6 19.1 10.7 14.7 1.6 19.1 11.5 14.2 1.7 19.9 9.9 130 7 136 165 10.1 0 10.3 9.8 08/03/2006 05:40:00 15.6 1.7 19.5 9.9 15.9 1.7 19.9 9.9 15.3 1.7 19.5 9.1 122 6 112 165 10.1 0 10.3 9.6 08/03/2006 05:50:00 15 1.9 19.9 9.1 15.3 2 20.2 9.9 14.5 1.9 19.1 10.7 121 7 121 165 10 0 10.3 9.6 08/03/2006 06:00:00 15.2 1.8 19.9 9.9 15.5 1.8 20.6 9.9 14.7 2 19.9 8.4 120 7 107 165 10 0 10.3 9.8 08/03/2006 06:10:00 15.9 1.7 19.9 11.1 16.2 1.7 20.2 11.1 15.2 1.7 19.9 11.1 117 6 121 165 10 0 10.3 9.6 08/03/2006 06:20:00 15.5 1.9 21.4 11.1 15.8 1.9 21.4 11.5 14.9 2.1 21.4 8.8 116 7 113 165 10 0 10.3 9.6 08/03/2006 06:30:00 15.7 1.8 21 10.3 16 1.9 21 9.5 15 2.2 20.6 9.1 115 7 127 165 10 0 10.3 9.6 08/03/2006 06:40:00 16 1.7 20.6 11.5 16.3 1.7 21 11.8 15.2 1.8 19.9 9.9 117 6 116 165 10 0 10.3 9.8 08/03/2006 06:50:00 15 1.9 20.2 9.5 15.3 2 20.6 9.1 14.2 2.1 20.2 9.1 116 6 121 165 10.1 0 10.3 9.8 08/03/2006 07:00:00 15.9 1.8 20.2 11.8 16.2 1.8 20.6 12.2 15 2 19.9 10.7 113 6 112 165 10.1 0 10.3 9.8 08/03/2006 07:10:00 16.8 1.6 21 12.2 17.1 1.6 21.4 12.2 16.1 1.7 20.6 10.7 113 7 112 165 10.1 0 10.3 9.8 08/03/2006 07:20:00 15.4 1.6 19.9 11.1 15.7 1.7 21 10.7 14.2 1.7 17.9 9.5 113 7 118 165 10.1 0 10.3 9.8 08/03/2006 07:30:00 15.4 1.8 18.7 9.5 15.7 1.9 19.5 10.3 14.5 1.8 18.3 8 114 7 111 165 10.2 0 10.6 9.8 08/03/2006 07:40:00 15.1 1.9 20.2 10.3 15.4 2 20.2 9.9 14.1 2.2 21 8.8 113 7 126 165 10.2 0 10.3 10.3 08/03/2006 07:50:00 14.2 1.7 19.1 9.1 14.5 1.7 19.1 9.5 13.5 1.7 17.9 8.4 114 8 115 165 10.3 0 10.6 10.3 08/03/2006 08:00:00 14.9 1.5 19.5 11.1 15.2 1.6 19.5 11.5 14.2 1.7 19.9 9.5 116 7 121 165 10.3 0 10.6 10.3 08/03/2006 08:10:00 14.9 1.9 19.1 9.9 15.2 1.9 19.5 9.9 14.2 2 19.1 9.5 118 7 112 165 10.4 0 10.6 10.3 08/03/2006 08:20:00 15.3 1.6 19.5 10.3 15.6 1.7 19.9 10.3 14.6 1.7 19.9 9.9 117 7 121 165 10.4 0 10.6 10.3 08/03/2006 08:30:00 15.3 1.7 19.5 10.3 15.6 1.7 19.5 9.1 14.6 1.9 19.1 8.8 117 6 117 165 10.5 0 10.6 10.1 08/03/2006 08:40:00 15.2 1.7 20.2 11.1 15.5 1.7 20.2 11.5 14.6 1.7 19.1 9.9 120 7 116 165 10.5 0 10.6 10.3 08/03/2006 08:50:00 14.4 1.8 21 9.1 14.7 1.9 21.4 9.1 13.9 1.8 20.6 8.8 120 7 126 165 10.5 0 10.9 10.6 08/03/2006 09:00:00 15.4 1.5 19.1 10.7 15.7 1.5 19.9 10.7 14.8 1.7 19.5 9.9 119 6 114 165 10.5 0 10.6 10.3 08/03/2006 09:10:00 14.7 1.6 20.2 11.1 14.9 1.7 19.9 11.1 14.1 1.7 19.1 10.7 120 8 112 165 10.5 0 10.9 10.3 08/03/2006 09:20:00 14.3 1.7 18.7 10.7 14.6 1.7 18.7 10.3 13.7 1.8 18.7 9.5 120 6 127 165 10.5 0 10.6 9.8 08/03/2006 09:30:00 14.1 1.7 17.9 9.5 14.4 1.7 18.3 9.5 13.7 1.7 17.9 8.8 122 7 114 165 10.4 0.1 10.9 9.8 08/03/2006 09:40:00 13.1 1.3 17.6 9.1 13.3 1.3 17.2 9.9 12.7 1.5 16.8 8 122 7 109 165 10.5 0.2 10.9 10.1 08/03/2006 09:50:00 13 1.5 16.4 9.1 13.3 1.5 16.8 9.1 12.7 1.7 16.1 8 122 7 124 165 10.6 0.2 10.9 10.3 08/03/2006 10:00:00 12.2 1.5 16.1 8.4 12.4 1.5 16.1 8.8 11.7 1.5 15.6 7.2 120 8 113 165 10.7 0.2 10.9 10.3 08/03/2006 10:10:00 11.9 1.6 15.3 8 12.1 1.7 15.6 8 11.6 1.7 15.3 7.6 122 7 128 165 10.7 0.1 10.9 10.3 08/03/2006 10:20:00 10.9 1.2 13.7 7.2 11 1.2 14.1 6.8 10.6 1.2 13.7 7.2 123 6 126 165 10.7 0.2 11.1 10.3 08/03/2006 10:30:00 10.5 1 13 7.6 10.7 1 13.3 8 10.3 1 12.6 7.2 123 8 112 165 10.8 0.1 11.1 10.3 08/03/2006 10:40:00 10.3 1.2 14.5 7.6 10.4 1.2 14.5 7.2 10 1.3 13.7 6.5 125 8 139 165 10.9 0 11.1 10.6 08/03/2006 10:50:00 10.3 1.3 13.3 7.2 10.5 1.3 13.7 6.8 10 1.2 13 6.8 128 8 110 165 11 0 11.4 10.9 08/03/2006 11:00:00 10 1.2 14.1 6.8 10.1 1.2 14.1 6.8 9.7 1.2 13.7 6.8 129 8 123 165 11.1 0 11.4 10.9 08/03/2006 11:10:00 9.9 1 12.2 7.6 10 1 12.2 7.6 9.7 1.1 12.6 6.8 131 7 143 165 11.1 0 11.4 10.9 08/03/2006 11:20:00 10 1 12.2 6.5 10.2 1.1 12.2 6.5 9.9 1.2 13 7.2 130 7 128 165 11.1 0 11.4 10.9 08/03/2006 11:30:00 9.6 1.1 11.8 6.5 9.7 1.1 12.2 7.2 9.5 1 11.8 7.2 134 7 132 165 11.1 0.1 11.4 10.9 08/03/2006 11:40:00 9.8 1 12.2 6.5 9.9 1 12.2 6.5 9.6 1.1 11.8 5.7 136 8 135 165 11.2 0 11.4 10.9 08/03/2006 11:50:00 9.6 1 11.8 7.6 9.7 1 12.2 7.6 9.5 1 11.5 7.2 135 7 136 165 11.1 0.1 11.4 10.9 08/03/2006 12:00:00 9.3 1 11.8 6.8 9.3 1 12.2 6.8 9 1.1 11.8 6.1 135 7 130 165 11.2 0.1 11.4 10.9 08/03/2006 12:10:00 9.5 0.8 11.5 7.6 9.6 0.8 11.5 7.6 9.3 1 11.5 6.5 133 6 135 165 11.1 0 11.4 10.9 08/03/2006 12:20:00 8.9 0.8 11.1 6.8 8.9 0.8 11.1 7.2 8.6 0.9 10.7 6.1 135 5 140 165 11.1 0 11.4 10.9 08/03/2006 12:30:00 9 1 11.1 6.5 9.1 1 11.1 6.5 8.8 1 11.1 6.1 133 6 131 165 11.1 0 11.4 10.9 08/03/2006 12:40:00 8.6 0.9 11.1 6.1 8.6 0.9 11.1 6.1 8.3 1 10.7 6.1 134 6 130 165 11.1 0 11.4 10.9 08/03/2006 12:50:00 8.5 0.7 10.7 6.5 8.7 0.7 10.7 6.8 8.2 0.8 9.9 5.3 133 6 139 165 11.2 0.1 11.4 10.9 08/03/2006 13:00:00 8.3 0.8 9.9 6.1 8.4 0.8 10.3 6.5 8 0.8 9.9 5.3 133 6 135 165 11.3 0 11.4 10.9 08/03/2006 13:10:00 8.2 0.7 10.3 6.5 8.3 0.7 10.3 6.5 8.1 0.9 10.3 5.7 131 6 138 165 11.3 0 11.4 11.1 08/03/2006 13:20:00 8.1 0.7 9.9 6.1 8.2 0.7 10.3 6.1 7.9 0.8 9.9 5.7 133 6 136 165 11.3 0 11.4 11.1 08/03/2006 13:30:00 8.6 0.7 10.3 6.5 8.7 0.8 10.7 6.5 8.2 0.9 11.1 5.3 134 6 126 165 11.3 0 11.4 11.1 08/03/2006 13:40:00 8.7 0.9 10.7 5.7 8.8 0.9 10.7 6.1 8.4 1 10.7 5.7 135 5 128 165 11.3 0 11.4 11.1 08/03/2006 13:50:00 8.9 0.9 11.1 6.1 9 0.9 11.1 6.5 8.6 1 11.1 5.7 136 5 142 165 11.3 0 11.7 11.1 08/03/2006 14:00:00 8.6 0.8 10.7 6.5 8.7 0.8 10.7 6.8 8.3 0.9 10.7 5.7 135 5 135 165 11.4 0 11.7 11.4 08/03/2006 14:10:00 7.8 0.7 9.5 6.1 7.9 0.7 9.5 6.1 7.7 0.8 9.9 5.3 135 5 134 165 11.5 0 11.7 11.4 08/03/2006 14:20:00 7.4 0.7 9.1 5.7 7.5 0.7 9.1 5.7 7.3 0.6 8.8 5.7 129 6 138 165 11.4 0 11.7 11.4 08/03/2006 14:30:00 7.2 0.7 8.8 5.3 7.3 0.7 8.8 5.3 7 0.8 9.5 4.9 133 6 115 165 11.5 0 11.7 11.1 08/03/2006 14:40:00 7.3 0.7 9.5 5.3 7.4 0.7 9.5 5.7 7.2 0.8 9.1 4.9 129 5 137 165 11.3 0 11.7 11.4 08/03/2006 14:50:00 6.9 0.6 8.8 5.3 7 0.6 9.1 5.7 6.8 0.6 8.8 4.9 128 6 122 165 11.3 0 11.7 11.1 08/03/2006 15:00:00 6.9 0.6 8.4 5.7 7.1 0.6 8.4 5.7 6.8 0.7 8.4 4.6 128 6 122 165 11.4 0 11.7 11.4 08/03/2006 15:10:00 6.6 0.6 8.4 4.9 6.7 0.7 8.4 4.9 6.5 0.7 8.4 4.6 129 6 136 165 11.4 0 11.7 11.4 08/03/2006 15:20:00 6.4 0.6 7.6 4.6 6.5 0.6 8 4.6 6.3 0.6 7.6 4.2 126 6 116 165 11.3 0 11.4 11.1 08/03/2006 15:30:00 6.2 0.5 7.2 4.2 6.3 0.5 7.6 4.6 6.2 0.6 7.6 4.6 127 5 132 165 11.3 0 11.4 11.1 08/03/2006 15:40:00 5.7 0.6 7.2 3.8 5.8 0.7 7.2 3.8 5.6 0.6 6.8 4.2 127 5 130 165 11.3 0 11.4 11.1 08/03/2006 15:50:00 5.3 0.5 6.8 4.2 5.4 0.5 6.8 4.2 5.4 0.5 6.5 3.8 124 5 128 165 11.3 0 11.4 11.1 08/03/2006 16:00:00 5.1 0.5 6.8 3.8 5.2 0.5 6.8 4.2 5.2 0.5 6.5 4.2 126 4 127 165 11.3 0 11.7 11.1 08/03/2006 16:10:00 5.6 0.4 6.5 4.2 5.7 0.4 6.8 4.2 5.5 0.5 6.5 4.2 121 5 128 165 11.3 0 11.7 11.1 08/03/2006 16:20:00 5.1 0.6 6.5 3.4 5.2 0.5 6.5 3.4 5.1 0.5 6.1 3.8 120 5 128 165 11.3 0 11.7 11.1 08/03/2006 16:30:00 4.5 0.5 5.7 2.3 4.6 0.5 5.7 2.6 4.5 0.5 5.3 2.3 120 6 116 165 11.3 0 11.7 11.1 08/03/2006 16:40:00 4.4 0.5 5.3 3 4.5 0.5 5.7 3.4 4.4 0.5 5.7 3 118 5 113 165 11.3 0 11.4 11.1 08/03/2006 16:50:00 3.6 0.5 4.6 2.6 3.8 0.5 4.9 2.3 3.7 0.5 4.9 2.3 112 6 114 165 11.3 0 11.4 10.6 08/03/2006 17:00:00 3 0.4 3.8 1.5 3.2 0.4 4.2 1.9 3.2 0.4 3.8 2.3 103 5 104 165 11.3 0 11.4 11.1 08/03/2006 17:10:00 2.5 0.4 3.4 1.1 2.7 0.4 3.8 1.5 2.8 0.4 3.8 1.9 105 5 99 165 11.3 0 11.7 11.1 08/03/2006 17:20:00 2.6 0.3 3 1.9 2.7 0.3 3.4 1.9 2.9 0.3 3.8 2.3 102 5 107 165 11.3 0 11.7 11.1 08/03/2006 17:30:00 2.1 0.4 2.6 0.7 2.2 0.4 3 1.1 2.4 0.4 3 1.5 94 5 91 165 11.3 0 11.7 11.1 08/03/2006 17:40:00 1.9 0.3 2.6 1.1 2.1 0.3 2.6 1.1 2.4 0.3 3 1.9 92 5 92 165 11.4 0 11.7 11.4 08/03/2006 17:50:00 1.4 0.6 2.6 0.4 1.7 0.6 3 0.4 1.9 0.4 3 1.1 82 9 91 165 11.5 0 11.9 11.4 08/03/2006 18:00:00 0.7 0.5 2.6 0.4 0.9 0.6 2.6 0.4 1.2 0.6 2.6 0.4 69 13 78 165 11.8 0 11.9 11.7 08/03/2006 18:10:00 0.7 0.4 2.3 0.4 0.8 0.5 2.3 0.4 0.8 0.5 2.6 0.4 64 24 41 165 11.9 0 11.9 11.4 08/03/2006 18:20:00 1.2 0.6 2.3 0.4 1.3 0.6 2.6 0.4 1.6 0.7 2.6 0.4 55 20 50 165 12 0 12.2 11.4 08/03/2006 18:30:00 1.3 0.6 3 0.4 1.4 0.7 3 0.4 1.9 0.5 3 0.4 40 12 46 165 11.9 0.1 12.2 11.4 08/03/2006 18:40:00 1.5 0.5 2.6 0.4 1.6 0.5 3 0.4 2 0.5 3 0.7 35 10 25 165 11.8 0 11.9 11.7 08/03/2006 18:50:00 2.2 0.5 3.4 0.4 2.2 0.5 3 0.7 2.5 0.5 3.8 0.7 32 8 39 165 11.7 0 11.9 11.7 08/03/2006 19:00:00 2.3 0.4 3 1.1 2.3 0.4 3.4 1.5 2.8 0.3 3.4 1.9 28 6 31 165 11.7 0 11.7 11.7 08/03/2006 19:10:00 2.5 0.3 3.4 1.5 2.4 0.4 3 1.5 3 0.3 3.8 2.3 24 5 31 165 11.6 0 11.7 11.4 08/03/2006 19:20:00 2.8 0.3 3.4 1.9 2.6 0.4 3.4 1.9 3.1 0.4 3.8 2.3 23 4 10 165 11.5 0 11.7 11.4 08/03/2006 19:30:00 2.9 0.3 3.4 2.3 2.8 0.3 3.4 1.9 3.3 0.3 4.2 2.3 27 4 21 165 11.4 0 11.7 11.1 08/03/2006 19:40:00 2.6 0.3 3.4 1.9 2.6 0.3 3.4 1.9 3 0.3 3.8 2.3 29 5 31 165 11.3 0 11.4 11.1 08/03/2006 19:50:00 2.6 0.3 3 1.9 2.5 0.3 3 1.5 3 0.4 3.4 1.9 27 4 27 165 11.3 0 11.4 11.1 08/03/2006 20:00:00 2.5 0.3 3 1.5 2.2 0.3 2.6 1.1 2.8 0.4 3.4 1.9 20 5 20 165 11.3 0 11.4 11.1 08/03/2006 20:10:00 2.8 0.2 3.4 1.9 2.4 0.3 3 1.5 3.1 0.3 3.8 1.9 17 2 21 165 11.3 0 11.4 11.1 08/03/2006 20:20:00 3.2 0.2 3.4 3 2.9 0.2 3.4 2.3 3.4 0.2 3.8 2.6 20 1 20 165 11.2 0.1 11.4 10.9 08/03/2006 20:30:00 3.2 0.2 3.4 2.6 2.9 0.2 3.4 2.6 3.4 0.2 3.8 2.6 20 1 20 165 11.1 0.1 11.4 10.9 08/03/2006 20:40:00 3.4 0.2 3.8 3 3 0.3 3.8 2.3 3.6 0.3 4.2 2.6 17 3 18 165 11.1 0 11.4 10.9 08/03/2006 20:50:00 3.2 0.3 3.8 2.3 1.8 0.5 3 0.7 3.8 0.2 4.6 3 7 3 14 165 11 0.2 11.4 10.9 08/03/2006 21:00:00 3.2 0.2 3.8 2.6 1.9 0.6 3.8 0.7 3.9 0.2 4.6 3.4 8 4 6 165 11.1 0.1 11.4 10.6 08/03/2006 21:10:00 3.2 0.3 3.8 2.6 2 0.6 3.8 0.7 3.9 0.2 4.6 3.4 9 4 12 165 11 0.2 11.4 10.9 08/03/2006 21:20:00 3.2 0.4 3.8 2.3 2 0.7 3.4 0.4 3.6 0.3 4.2 2.6 8 3 6 165 11.1 0.2 11.4 10.9 08/03/2006 21:30:00 2.3 0.2 2.6 1.5 1.3 0.5 2.6 0.4 2.9 0.2 3.4 2.3 7 5 9 165 11.1 0.2 11.4 10.9 08/03/2006 21:40:00 1.1 0.6 2.6 0.4 0.7 0.4 2.3 0.4 1.6 0.5 2.6 0.7 4 10 11 165 11.1 0.2 11.4 10.9 08/03/2006 21:50:00 0.5 0.2 1.1 0.4 0.4 0.2 1.1 0.4 0.8 0.5 1.9 0.4 353 21 20 165 11.1 0.2 11.4 10.9 08/03/2006 22:00:00 0.6 0.2 1.1 0.4 0.4 0.1 0.7 0.4 0.9 0.3 1.5 0.4 346 4 340 165 11.1 0.2 11.4 10.9 08/03/2006 22:10:00 1.3 0.5 2.6 0.4 1.1 0.5 2.3 0.4 1.5 0.4 2.6 0.4 329 11 342 165 11 0.1 11.4 10.9 08/03/2006 22:20:00 1.2 0.5 2.3 0.4 1 0.5 2.3 0.4 1.5 0.4 2.6 0.7 329 5 333 165 11 0.2 11.4 10.6 08/03/2006 22:30:00 2.1 0.4 3 1.5 1.8 0.4 2.6 0.7 2.3 0.3 3 1.9 344 4 346 165 10.9 0.2 11.4 10.6 08/03/2006 22:40:00 3.1 0.4 3.8 2.3 1.9 0.5 3 0.7 3.2 0.4 4.2 2.3 354 5 352 165 10.9 0.2 11.1 10.6 08/03/2006 22:50:00 3.5 0.5 4.6 1.9 2.2 0.8 4.2 0.4 3.6 0.5 4.9 2.6 356 7 2 165 10.9 0.2 11.1 10.6 08/03/2006 23:00:00 3.7 0.3 4.2 2.6 2.7 0.7 3.8 1.1 3.8 0.3 4.6 3 353 5 347 165 10.9 0.1 11.1 10.3 08/03/2006 23:10:00 4.2 0.6 6.1 3 3.2 0.9 5.3 1.5 4.2 0.5 5.7 3 351 6 356 165 10.9 0 11.1 10.3 08/03/2006 23:20:00 3.2 0.5 4.6 1.1 2.4 0.8 4.6 0.4 3.3 0.5 4.6 2.3 352 6 348 165 10.9 0 11.1 10.3 08/03/2006 23:30:00 2.1 1 4.2 0.4 1.6 1 4.2 0.4 2.4 0.9 4.2 0.7 348 13 337 165 10.9 0 11.1 10.6 08/03/2006 23:40:00 1.5 0.9 3.8 0.4 1.3 0.9 3.4 0.4 1.8 0.8 4.2 0.4 326 18 346 165 10.9 0 11.1 10.3 08/03/2006 23:50:00 1.7 0.7 3.8 0.4 1.8 0.7 3.4 0.4 1.7 0.6 3.4 0.4 305 16 4 165 10.9 0.1 11.1 10.6 08/04/2006 00:00:00 2.4 0.4 3 1.1 2.4 0.4 3.4 0.7 2.1 0.5 3.4 0.7 294 7 292 165 10.8 0.1 11.1 10.3 08/04/2006 00:10:00 4 0.6 6.1 2.6 3.9 0.7 6.1 2.6 3.2 0.7 5.7 1.9 295 5 295 165 10.8 0.1 11.1 10.3 08/04/2006 00:20:00 4.6 0.5 6.1 3.4 4.6 0.5 6.5 3 3.9 0.6 6.1 2.6 297 6 287 165 10.9 0 11.1 10.6 08/04/2006 00:30:00 3.9 0.7 5.3 1.9 3.8 0.6 5.3 2.3 3.5 0.6 5.3 1.5 301 11 322 165 10.9 0.1 11.4 10.3 08/04/2006 00:40:00 3.8 0.5 4.9 2.6 3.7 0.5 4.9 2.3 3.2 0.6 4.6 1.5 305 9 299 165 10.9 0.1 11.4 10.3 08/04/2006 00:50:00 3.3 0.5 4.6 1.9 3.2 0.5 4.6 1.5 3 0.5 4.2 1.9 310 9 349 165 10.9 0.1 11.1 10.3 08/04/2006 01:00:00 2.3 0.6 3.8 0.7 2.3 0.6 3.8 0.4 2.2 0.7 3.8 0.4 311 9 307 165 10.9 0.1 11.1 10.6 08/04/2006 01:10:00 1.2 0.7 3 0.4 1 0.7 3 0.4 1.1 0.6 3 0.4 321 18 325 165 10.9 0.1 11.1 10.3 08/04/2006 01:20:00 3 1 4.9 0.7 2.9 1 4.9 1.1 2.5 0.8 4.6 0.7 301 7 301 165 10.9 0 11.1 10.6 08/04/2006 01:30:00 4.9 0.6 6.5 3.4 4.8 0.6 6.1 3 3.7 0.7 5.7 1.9 295 6 292 165 11.1 0 11.1 10.9 08/04/2006 01:40:00 4.9 0.7 6.5 2.6 4.8 0.7 6.1 2.3 3.8 0.6 5.7 2.3 299 8 296 165 11.1 0 11.4 10.6 08/04/2006 01:50:00 4.4 0.9 6.5 2.3 4.3 0.9 6.5 1.9 4.1 0.8 6.1 2.3 313 9 298 165 11.1 0 11.4 10.6 08/04/2006 02:00:00 5 0.6 6.8 2.6 4.9 0.6 6.8 2.6 4.3 0.5 6.1 3 308 7 302 165 11.1 0 11.4 11.1 08/04/2006 02:10:00 5.5 1 8 2.6 5.4 1 7.6 2.3 4.6 0.8 6.5 2.6 309 11 302 165 11.1 0 11.4 10.9 08/04/2006 02:20:00 5.3 1 7.6 3 5.2 0.9 7.2 3 4.3 0.8 6.8 2.3 308 11 298 165 11.1 0 11.4 10.9 08/04/2006 02:30:00 6.4 0.8 8.4 3.4 6.2 0.8 8 2.6 5 0.8 7.2 3 300 7 298 165 11.1 0 11.1 10.9 08/04/2006 02:40:00 6.4 0.8 8.4 4.6 6.3 0.7 8.8 4.2 4.8 0.6 6.5 3.4 303 5 297 165 11 0 11.4 10.9 08/04/2006 02:50:00 6.4 0.7 8.4 4.6 6.3 0.6 8.4 4.6 4.9 0.8 6.8 2.6 303 5 300 165 11 0 11.1 10.9 08/04/2006 03:00:00 6.2 0.8 8 4.6 6.2 0.7 8 4.2 5 0.8 7.2 3.4 305 6 304 165 10.9 0 11.1 10.9 08/04/2006 03:10:00 6.5 0.9 9.1 3.8 6.5 0.9 9.1 4.2 5.6 0.9 8 3.4 311 7 297 165 10.8 0 11.1 10.9 08/04/2006 03:20:00 8.5 1.2 11.8 4.9 8.3 1.2 11.5 4.9 6.6 1.2 10.7 3 302 6 313 165 10.7 0 10.9 10.6 08/04/2006 03:30:00 10.5 1.1 12.6 7.2 10.3 1 12.2 6.8 8.1 1.1 12.2 5.7 303 6 295 165 10.7 0 10.9 10.6 08/04/2006 03:40:00 11.8 1.1 15.3 8.4 11.7 1 14.9 8 9.4 1.1 12.2 6.5 305 5 302 165 10.7 0 10.9 10.3 08/04/2006 03:50:00 13.6 1 15.6 10.3 13.5 1 15.6 9.9 11.2 1 14.5 8.8 307 4 307 165 10.7 0 10.9 10.6 08/04/2006 04:00:00 14.8 0.7 16.8 12.6 14.8 0.7 16.8 12.6 13.3 1.2 16.1 10.7 309 5 316 165 10.7 0 11.1 10.6 08/04/2006 04:10:00 15.4 0.8 18.3 13 15.4 0.8 17.6 13 14.2 1.1 16.8 11.1 310 4 300 165 10.7 0 10.9 10.6 08/04/2006 04:20:00 15.6 1 17.9 11.8 15.6 1 17.9 11.8 14.1 1.1 17.6 10.7 310 4 313 165 10.7 0 10.9 10.3 08/04/2006 04:30:00 16.6 0.9 18.7 14.1 16.6 0.9 18.7 14.1 14.6 1.2 17.9 11.8 309 4 305 165 10.7 0 10.9 10.6 08/04/2006 04:40:00 15.6 1 17.9 12.6 15.5 1 17.9 12.2 14.2 1.1 17.2 10.3 310 5 303 165 10.7 0 10.9 10.6 08/04/2006 04:50:00 15.2 1 18.7 12.6 15.1 1 18.7 12.2 14.3 1.1 17.9 11.1 312 5 308 165 10.7 0 10.9 10.6 08/04/2006 05:00:00 15.1 1 17.9 12.6 15.1 1 18.3 12.2 13.8 1.2 16.4 10.3 309 4 305 165 10.7 0 10.9 10.3 08/04/2006 05:10:00 14.6 1 17.2 11.8 14.6 1.1 17.2 11.1 13.1 1.2 16.4 8 309 5 305 165 10.7 0 10.9 10.3 08/04/2006 05:20:00 15.2 1.2 18.7 11.8 15.2 1.2 18.7 11.8 13 1.5 17.2 9.5 308 6 298 165 10.7 0 10.9 10.3 08/04/2006 05:30:00 15.9 1.5 20.6 12.2 15.8 1.5 20.2 12.6 13.9 1.6 17.6 9.5 310 7 308 165 10.7 0 10.9 10.3 08/04/2006 05:40:00 16.8 1.3 21.4 13.7 16.8 1.4 21 13.7 16.1 1.3 20.6 12.6 316 6 322 165 10.7 0 10.9 10.6 08/04/2006 05:50:00 15.9 1.3 19.5 12.2 15.9 1.3 19.5 12.2 15 1.6 19.5 8.8 313 6 313 165 10.7 0 10.9 10.6 08/04/2006 06:00:00 16.1 1.2 20.2 13 16 1.2 19.5 12.2 13.7 1.5 17.9 9.9 307 6 300 165 10.7 0 11.1 10.6 08/04/2006 06:10:00 15.6 1.6 21.8 10.7 15.5 1.6 21.8 10.7 13.7 1.6 18.3 10.3 308 8 291 165 10.6 0 10.9 10.6 08/04/2006 06:20:00 14.8 1.7 18.3 7.2 14.7 1.7 18.3 7.6 12.5 1.5 17.2 7.6 307 7 299 165 10.7 0 10.9 10.6 08/04/2006 06:30:00 16.1 1.8 22.6 11.1 16 1.8 22.9 10.7 14.3 1.7 19.1 9.5 309 9 290 165 10.7 0 10.9 10.6 08/04/2006 06:40:00 16.5 2.2 23.7 11.5 16.4 2.1 23.3 11.1 15.2 2.3 22.1 8.4 315 11 303 165 10.7 0 11.1 10.9 08/04/2006 06:50:00 16 2.1 22.9 10.7 15.9 2.1 22.6 10.3 14.9 1.9 21 9.9 314 11 293 165 10.8 0 11.1 10.9 08/04/2006 07:00:00 16.5 2.2 22.9 10.7 16.4 2.1 22.6 11.5 14.8 2.1 21.8 9.1 308 10 300 165 11.1 0 11.4 10.9 08/04/2006 07:10:00 14.6 1.9 21 10.7 14.5 1.9 21.4 10.3 13.4 1.9 21.4 9.1 316 10 310 165 11.1 0 11.4 10.9 08/04/2006 07:20:00 13.6 2.1 21 8 13.5 2.1 21 7.2 12.6 2.2 20.6 6.5 318 11 328 165 11.1 0 11.4 11.1 08/04/2006 07:30:00 13.4 2.1 18.7 4.9 13.2 2.1 17.2 4.9 12.4 2.1 17.2 6.5 320 17 296 165 11.1 0 11.4 10.9 08/04/2006 07:40:00 12.9 2.1 19.1 7.2 12.8 2.1 19.1 7.2 11.9 2.2 16.8 6.5 318 12 292 165 11.1 0 11.4 10.9 08/04/2006 07:50:00 13.5 1.6 18.7 9.5 13.4 1.6 17.9 9.5 12.1 1.8 18.3 7.2 312 10 317 165 11 0 11.1 10.9 08/04/2006 08:00:00 13.1 1.7 20.6 9.1 13 1.7 20.2 8.8 11.9 1.7 20.2 7.6 313 9 323 165 10.9 0 11.1 10.9 08/04/2006 08:10:00 15.4 1.6 21 10.3 15.3 1.6 20.6 10.3 13.8 1.8 18.7 8.8 310 8 317 165 10.8 0.2 11.1 10.3 08/04/2006 08:20:00 16.4 1.2 19.1 13.3 16.4 1.2 19.1 13.3 15.3 1.4 19.1 9.9 311 4 305 165 10.6 0.2 10.9 10.1 08/04/2006 08:30:00 18 1.5 21.8 14.9 18 1.5 21.8 14.5 16.6 1.3 21 13.3 311 6 310 165 10.7 0.1 11.1 10.3 08/04/2006 08:40:00 19.2 1.3 22.9 14.9 19.2 1.3 22.6 15.3 17.9 1.4 21.8 14.5 311 5 310 165 10.7 0.1 10.9 10.3 08/04/2006 08:50:00 19.4 1 22.9 15.6 19.4 1 22.9 15.6 17.6 1.3 20.6 13.7 309 4 307 165 10.7 0.1 11.1 10.3 08/04/2006 09:00:00 19.5 1.2 22.6 14.9 19.5 1.3 22.9 14.9 18.1 1.3 21.8 14.5 311 4 306 165 10.9 0.1 11.4 10.3 08/04/2006 09:10:00 17.7 1.5 21 13.7 17.6 1.5 21.4 13.7 16.9 1.5 20.6 12.6 314 6 309 165 11.1 0 11.4 10.9 08/04/2006 09:20:00 16.5 1.3 20.2 12.6 16.5 1.3 20.2 13 15.9 1.4 20.2 12.2 316 7 315 165 11.2 0 11.4 11.1 08/04/2006 09:30:00 16.7 1.3 19.9 13.3 16.6 1.3 19.9 13 16 1.4 19.1 11.5 316 8 311 165 11.2 0 11.4 11.1 08/04/2006 09:40:00 16.6 1.5 21 13 16.5 1.5 20.6 13 16.1 1.5 21.8 12.2 317 7 330 165 11.1 0 11.1 10.9 08/04/2006 09:50:00 17.1 1.3 20.6 13.3 17 1.4 20.6 13.3 16.4 1.7 22.6 12.2 316 7 319 165 11.5 0 11.7 11.1 08/04/2006 10:00:00 17.5 1.4 21.8 13.3 17.5 1.4 21.8 13.7 16.7 1.7 21.8 12.2 314 8 319 165 11.3 0.1 11.7 11.4 08/04/2006 10:10:00 16.5 1.1 20.2 14.1 16.5 1.2 20.6 14.1 16 1.3 20.6 12.6 313 7 313 165 11.2 0 11.4 11.1 08/04/2006 10:20:00 16 1 19.1 12.6 16 1 18.7 12.6 15 1.3 18.3 11.1 312 7 315 165 11.1 0 11.4 10.9 08/04/2006 10:30:00 16 1.3 21.8 12.2 15.9 1.4 22.6 12.6 14.9 1.7 22.1 10.7 311 8 313 165 11.3 0 11.7 11.1 08/04/2006 10:40:00 16.7 1.7 22.6 13 16.6 1.7 22.9 13 16 1.6 20.6 12.6 314 7 313 165 11.3 0 11.7 10.9 08/04/2006 10:50:00 16.3 1.5 20.2 12.6 16.2 1.5 20.2 12.2 14.9 1.7 19.9 11.1 310 7 317 165 11.2 0 11.4 10.9 08/04/2006 11:00:00 15.6 1.3 19.5 10.3 15.6 1.3 19.5 10.7 14.4 1.7 19.9 9.9 310 8 311 165 11.3 0.1 11.7 11.1 08/04/2006 11:10:00 15.4 1.3 19.5 11.8 15.3 1.3 19.1 11.8 13.9 1.3 17.6 10.3 311 6 316 165 11.5 0 11.7 11.1 08/04/2006 11:20:00 15.5 1.5 19.9 11.1 15.4 1.6 19.5 11.1 14.1 1.7 19.9 10.3 312 8 304 165 11.3 0.1 11.7 10.9 08/04/2006 11:30:00 14.8 1.4 17.9 11.5 14.8 1.4 17.6 11.1 14.1 1.4 17.6 10.7 316 6 322 165 11.1 0 11.4 10.9 08/04/2006 11:40:00 15.1 1.5 20.2 11.1 15 1.5 20.2 11.5 14.2 1.7 18.7 8.8 314 7 317 165 11.1 0 11.4 10.6 08/04/2006 11:50:00 14.9 1.1 17.9 11.8 14.9 1.1 17.9 11.8 14.3 1.2 17.9 9.9 313 6 312 165 11.1 0 11.1 10.3 08/04/2006 12:00:00 14.7 0.8 17.2 12.6 14.7 0.8 16.8 12.6 14.1 1 17.2 10.3 312 6 327 165 11.1 0 11.4 10.6 08/04/2006 12:10:00 14.5 1.1 19.1 12.2 14.4 1.1 19.5 12.2 14.1 1.2 19.5 10.7 313 6 328 165 11.1 0 11.4 10.9 08/04/2006 12:20:00 14.8 1 17.2 11.5 14.8 1 17.2 11.5 14.2 1 17.2 11.5 312 5 305 165 10.9 0 11.1 10.9 08/04/2006 12:30:00 14.4 1 16.8 10.7 14.4 1 16.4 11.1 13.8 1 16.4 11.1 312 4 308 165 10.9 0 11.1 10.9 08/04/2006 12:40:00 13.4 1.1 16.4 10.7 13.3 1.2 16.8 10.7 12.8 1.3 17.2 8.4 313 6 311 165 11.1 0 11.4 10.9 08/04/2006 12:50:00 13.5 1.1 16.8 9.9 13.5 1.1 16.8 10.3 12.2 1 14.9 8.4 308 5 308 165 11.2 0 11.4 11.1 08/04/2006 13:00:00 13.3 1 17.2 10.3 13.2 1 17.2 10.3 11.6 1.2 15.3 8.4 309 5 304 165 11.3 0 11.4 11.1 08/04/2006 13:10:00 13.1 1 15.6 10.3 12.9 1 15.6 10.3 12.3 1.1 14.9 8.8 312 4 307 165 11.3 0 11.4 11.1 08/04/2006 13:20:00 13.9 1.1 18.3 11.1 13.7 1.2 17.9 11.1 12.9 1.2 17.9 9.5 313 6 325 165 11.7 0.1 11.9 11.4 08/04/2006 13:30:00 14.5 1 17.6 11.8 14.3 0.9 17.6 11.8 13.2 1.2 16.1 9.9 311 5 305 165 12 0 12.2 11.7 08/04/2006 13:40:00 15.4 1.1 19.5 12.2 15.3 1.1 19.5 12.2 14.4 1.2 18.3 9.9 313 6 313 165 12.2 0 12.5 12.2 08/04/2006 13:50:00 15.7 1 18.3 13.7 15.5 1 18.3 13 13.9 1.5 18.7 10.3 311 5 314 165 12.3 0 12.5 11.9 08/04/2006 14:00:00 15.4 1.2 19.1 11.8 15.2 1.2 19.1 11.8 14.1 1.3 18.3 10.7 313 6 318 165 12.7 0 12.7 12.2 08/04/2006 14:10:00 15.5 1.7 21.4 12.2 15.4 1.7 21.8 11.8 13.9 2 21.8 9.9 312 9 310 165 12.8 0 13 12.5 08/04/2006 14:20:00 14.9 1.6 21 11.1 14.7 1.7 20.2 10.7 13.9 1.7 18.7 9.1 314 8 312 165 13 0 13.3 12.7 08/04/2006 14:30:00 14.6 1.7 20.6 10.7 14.5 1.7 20.2 10.3 13.6 1.6 19.5 9.1 316 8 325 165 13.2 0 13.3 13 08/04/2006 14:40:00 13.6 1.1 16.8 10.7 13.4 1.2 16.4 10.3 12.5 1.4 15.6 9.1 315 8 315 165 13.4 0.1 13.5 13.3 08/04/2006 14:50:00 13.2 1.6 17.6 8.4 12.9 1.6 17.2 7.2 12.5 1.7 16.4 8.8 319 10 314 165 13.5 0 13.8 13.5 08/04/2006 15:00:00 15.2 1.2 19.1 11.8 15 1.2 18.7 11.5 14.4 1.2 17.6 10.3 315 6 307 165 13.5 0 13.5 13.3 08/04/2006 15:10:00 14.5 1.3 18.3 11.5 14.2 1.3 17.9 11.5 13.5 1.6 17.9 8.8 316 8 315 165 13.5 0 13.5 13.3 08/04/2006 15:20:00 14.6 1.9 19.9 9.5 14.4 1.9 19.1 8.8 14.1 2 18.7 9.1 323 10 315 165 13.8 0 14.1 13.5 08/04/2006 15:30:00 13.8 1.7 19.1 9.1 13.6 1.7 18.7 9.1 13.1 1.7 16.8 7.6 321 9 306 165 14 0 14.1 13.8 08/04/2006 15:40:00 12.8 1.5 16.1 9.1 12.5 1.4 16.4 9.1 11.7 1.5 15.3 7.2 315 7 310 165 14 0 14.1 13.8 08/04/2006 15:50:00 12.5 1.1 15.6 8.8 12.3 1.1 15.3 8.4 11.8 1.1 15.6 8.4 316 6 314 165 14 0 14.4 13.8 08/04/2006 16:00:00 12 1.4 15.3 8.4 11.8 1.3 14.9 8.4 10.9 1.2 16.1 6.8 313 7 305 165 13.9 0 14.1 13.8 08/04/2006 16:10:00 11.3 1.1 15.3 8.8 11.1 1.1 14.9 8.8 10.5 1.2 13.3 7.2 314 8 304 165 13.8 0 14.1 13.5 08/04/2006 16:20:00 11.1 1.1 13.3 7.6 11 1 13.3 8 10.5 1.2 13.7 7.6 315 5 319 165 13.8 0 13.8 13.8 08/04/2006 16:30:00 9.4 1.3 12.2 5.3 9.2 1.3 11.8 5.3 9.2 1.5 12.6 6.1 320 9 315 165 13.9 0 14.1 13.8 08/04/2006 16:40:00 9.5 1.2 12.6 7.2 9.4 1.2 13 7.2 9.3 1.2 13 6.5 321 9 310 165 13.8 0 13.8 13.8 08/04/2006 16:50:00 10.2 1.2 13 7.2 10 1.1 13 7.2 10.1 1.1 12.6 7.2 322 7 323 165 13.7 0 14.1 13.5 08/04/2006 17:00:00 10.7 1.1 13.7 7.6 10.7 1.1 13.3 7.2 10.5 1.2 13.7 6.5 322 8 319 165 13.7 0 13.8 13.5 08/04/2006 17:10:00 10.4 1.2 13 7.6 10.3 1.2 13 7.2 10.4 1.2 13.7 7.2 327 8 324 165 13.7 0 13.8 13.5 08/04/2006 17:20:00 9.5 1 12.6 6.5 9.4 1 11.8 6.1 9.3 1.1 12.2 6.1 323 8 321 165 13.5 0 13.8 13.3 08/04/2006 17:30:00 9 1 11.5 6.5 8.9 1 11.5 6.1 8.9 1.1 11.1 5.7 323 8 333 165 13.3 0 13.5 13 08/04/2006 17:40:00 8.9 0.9 11.5 5.7 8.7 1 11.1 5.7 8.9 0.9 11.1 6.5 321 6 315 165 13.3 0 13.3 12.7 08/04/2006 17:50:00 8.1 0.8 9.9 5.7 8 0.8 9.9 5.7 7.7 0.8 9.5 5.7 318 8 310 165 13.2 0 13.3 12.7 08/04/2006 18:00:00 8.1 0.9 11.1 5.7 8 0.9 11.1 5.7 7.6 1.1 10.3 5.3 316 8 319 165 13.2 0 13.3 12.7 08/04/2006 18:10:00 8.4 1 10.3 5.7 8.2 1 10.3 4.9 7.8 0.9 9.9 5.3 312 7 307 165 13.2 0 13.3 12.7 08/04/2006 18:20:00 8.7 0.7 10.7 6.8 8.6 0.7 10.3 6.1 8 0.9 10.3 5.3 310 5 316 165 13.2 0 13.3 12.7 08/04/2006 18:30:00 9.2 0.7 12.2 7.2 9.2 0.7 12.2 7.2 8.4 1 11.1 6.1 310 6 302 165 13.1 0 13.3 13 08/04/2006 18:40:00 9.6 0.9 11.5 7.6 9.6 0.9 11.5 7.2 8.9 0.9 11.8 6.5 311 5 306 165 13 0 13.3 13 08/04/2006 18:50:00 9.7 0.8 11.5 7.6 9.6 0.8 11.8 7.6 8.8 0.9 11.1 5.7 312 6 310 165 13.1 0 13.3 13 08/04/2006 19:00:00 10.1 1 12.2 7.2 10 1 11.8 6.8 9.1 1 12.2 6.5 311 5 317 165 13 0 13.3 12.5 08/04/2006 19:10:00 9.7 0.9 12.2 7.2 9.6 1 11.8 7.2 8.6 1.1 11.1 5.7 309 7 301 165 12.9 0 13 12.5 08/04/2006 19:20:00 9.5 0.9 11.5 6.8 9.3 1 11.5 6.1 8.8 1 11.1 5.7 313 7 307 165 12.8 0 13 12.7 08/04/2006 19:30:00 10.6 0.9 12.6 8 10.5 0.9 12.6 8 10 1.1 12.6 7.2 312 5 304 165 12.7 0 13 12.5 08/04/2006 19:40:00 10.6 1 13 8.4 10.5 0.9 13 8 10.2 1.1 13 7.2 314 6 310 165 12.7 0 13 12.5 08/04/2006 19:50:00 9.9 0.8 12.2 8 9.8 0.8 12.2 7.6 9.4 0.9 12.2 7.2 313 5 302 165 12.7 0 12.7 12.5 08/04/2006 20:00:00 11.1 1.2 13.3 8 11 1.2 13.3 8 10.5 1.2 13.3 6.5 312 6 310 165 12.7 0 12.7 12.5 08/04/2006 20:10:00 11.4 1.2 14.9 8.4 11.2 1.1 14.5 8.4 10.9 1.2 14.5 8 318 8 322 165 12.7 0 13 12.5 08/04/2006 20:20:00 10.9 1.3 14.5 8 10.7 1.3 13.7 7.6 10.6 1.4 14.1 7.6 320 8 323 165 12.7 0 12.7 12.2 08/04/2006 20:30:00 11 1 13.7 8.8 10.9 1 13.7 8.4 10.3 1.2 13.3 6.8 313 7 310 165 12.5 0.1 12.7 11.9 08/04/2006 20:40:00 10.8 1.1 14.1 8 10.6 1.1 13.7 8 10.4 1.1 13 7.2 319 9 322 165 12.5 0 12.7 11.9 08/04/2006 20:50:00 11.5 1.3 14.9 7.6 11.3 1.3 14.5 7.6 11.4 1.5 15.6 7.6 321 7 313 165 12.5 0 12.7 12.5 08/04/2006 21:00:00 10.4 1.1 13 8 10.3 1.1 13 7.6 10.2 1.2 13.3 7.2 318 7 304 165 12.5 0 12.7 12.5 08/04/2006 21:10:00 10.2 1 13.7 6.1 10.1 1 14.1 6.5 9.6 1 12.2 6.8 315 8 309 165 12.4 0 12.5 12.5 08/04/2006 21:20:00 10.1 1 12.2 6.5 9.9 1 11.8 6.5 9.5 1 12.2 6.1 316 9 297 165 12.4 0 12.5 12.5 08/04/2006 21:30:00 10.7 0.9 13 8 10.6 0.9 13.3 7.6 9.7 1.3 12.6 6.8 312 8 305 165 12.4 0 12.5 12.2 08/04/2006 21:40:00 9.8 0.9 12.2 7.6 9.6 0.9 12.2 7.2 8.9 1 11.8 6.5 311 7 310 165 12.3 0 12.5 12.2 08/04/2006 21:50:00 8.9 0.9 11.5 6.1 8.8 0.9 11.5 6.1 7.9 1 10.3 4.9 308 5 310 165 12.3 0 12.5 12.2 08/04/2006 22:00:00 8.8 0.8 11.1 6.5 8.8 0.8 11.1 6.8 7.6 1 10.7 5.7 307 5 308 165 12.3 0 12.5 12.2 08/04/2006 22:10:00 8.4 0.8 11.8 5.7 8.3 0.8 11.5 5.7 7.4 0.9 10.7 4.6 309 6 312 165 12.1 0 12.5 11.9 08/04/2006 22:20:00 8.4 0.9 11.1 6.1 8.3 0.9 11.5 6.1 7.4 1.1 11.5 4.6 306 7 305 165 12.1 0 12.2 11.9 08/04/2006 22:30:00 8.4 0.8 10.7 6.5 8.4 0.8 11.1 6.1 7.9 0.9 10.7 5.3 312 7 309 165 11.8 0 12.2 11.7 08/04/2006 22:40:00 8.7 0.7 10.3 6.5 8.6 0.7 10.7 6.8 8.3 0.8 9.9 5.7 312 5 309 165 11.7 0 11.9 11.4 08/04/2006 22:50:00 8.7 0.8 10.3 6.8 8.6 0.8 10.7 6.5 8.5 0.8 10.3 6.8 315 5 317 165 11.7 0 11.9 11.4 08/04/2006 23:00:00 9.9 0.7 11.8 7.6 9.9 0.7 12.2 7.6 9.6 0.8 11.8 6.5 314 4 317 165 11.7 0 11.9 11.4 08/04/2006 23:10:00 10.2 0.8 12.2 8 10.1 0.8 11.8 8.4 9.7 0.9 11.8 7.2 315 4 314 165 11.7 0 11.9 11.4 08/04/2006 23:20:00 9.9 1 11.8 7.2 9.8 1 11.8 7.2 9.4 1 12.2 6.8 315 5 313 165 11.6 0 11.9 11.4 08/04/2006 23:30:00 9.4 0.9 12.6 6.8 9.3 1 12.2 6.8 8.6 1.1 11.5 5.3 313 6 308 165 11.5 0 11.7 11.1 08/04/2006 23:40:00 8.5 0.7 10.3 6.5 8.3 0.8 10.3 6.8 7.3 0.8 10.3 4.9 310 5 304 165 11.5 0 11.7 11.1 08/04/2006 23:50:00 8.5 0.8 10.7 6.5 8.4 0.8 10.3 6.5 7.2 0.8 9.9 4.9 306 8 305 165 11.4 0 11.7 10.9 08/05/2006 00:00:00 8.5 1.2 10.7 6.1 8.4 1.2 11.1 6.1 7.2 1.1 10.3 4.6 307 7 312 165 11.5 0.1 11.7 10.9 08/05/2006 00:10:00 9.4 0.8 11.5 6.8 9.4 0.8 11.5 6.8 7.3 0.9 11.5 5.3 300 6 295 165 11.5 0.2 11.9 10.9 08/05/2006 00:20:00 9.1 0.8 10.7 6.8 9.1 0.8 10.7 6.5 7.1 0.9 9.5 4.6 303 5 308 165 11.4 0.1 11.7 11.1 08/05/2006 00:30:00 8.1 0.9 10.3 5.7 8.1 0.9 10.3 5.7 6.7 1 9.5 4.2 305 6 307 165 11.2 0.3 11.7 10.9 08/05/2006 00:40:00 7.1 0.6 8.4 5.7 7 0.6 8.8 5.7 5.5 0.6 7.6 4.2 302 5 309 165 11.1 0.3 11.4 10.9 08/05/2006 00:50:00 6.7 1 8.4 3.8 6.6 1 8.4 3.8 5.2 0.8 7.2 2.6 301 5 310 165 11.2 0.2 11.7 10.6 08/05/2006 01:00:00 5.9 0.8 7.6 3.8 5.9 0.8 7.6 3.4 4.9 0.7 6.8 3.4 302 6 306 165 11.2 0 11.4 11.1 08/05/2006 01:10:00 4.8 0.7 6.8 3 4.8 0.7 6.8 2.6 4.3 0.7 6.1 2.3 307 9 286 165 11.1 0 11.4 10.9 08/05/2006 01:20:00 5 0.8 7.2 3 5 0.8 6.8 3 4.1 0.7 6.1 2.3 305 7 307 165 11.1 0 11.4 10.9 08/05/2006 01:30:00 5.7 0.6 7.2 4.2 5.7 0.6 7.6 3.8 4.6 0.6 6.5 2.6 300 7 291 165 11.1 0 11.1 10.9 08/05/2006 01:40:00 4.5 0.7 6.8 2.6 4.5 0.7 6.5 2.6 3.7 0.7 5.3 2.3 305 8 308 165 11.1 0 11.4 10.9 08/05/2006 01:50:00 5 0.8 6.8 3 5 0.8 7.2 3 4.3 0.8 6.5 2.3 306 7 307 165 11 0 11.1 10.9 08/05/2006 02:00:00 6.4 0.8 8.8 4.2 6.3 0.8 8.4 4.2 5.1 0.9 7.6 3.4 300 7 307 165 11 0 11.1 10.9 08/05/2006 02:10:00 7.2 0.6 9.1 5.7 7.1 0.6 8.8 5.7 5.6 0.7 8 4.2 298 5 297 165 11.1 0 11.1 10.9 08/05/2006 02:20:00 6.3 0.8 8 3.4 6.2 0.8 7.6 3.4 4.9 0.8 7.6 2.3 299 6 305 165 11 0 11.1 10.9 08/05/2006 02:30:00 6 0.7 8 4.6 6 0.7 7.6 4.2 4.7 0.6 6.5 3 297 6 293 165 10.8 0 11.1 10.3 08/05/2006 02:40:00 6.4 0.7 8 4.6 6.3 0.7 8 4.6 5.1 1 7.6 2.6 295 6 290 165 10.9 0 11.1 10.6 08/05/2006 02:50:00 5.8 0.8 7.6 3.8 5.8 0.8 7.6 3.8 4.3 0.9 7.2 2.3 295 7 279 165 10.9 0 11.1 10.6 08/05/2006 03:00:00 6.3 0.7 8 4.6 6.2 0.6 7.6 4.2 4.9 0.8 7.6 3 296 5 291 165 10.9 0 11.1 10.9 08/05/2006 03:10:00 6.4 0.8 8.4 3.8 6.3 0.8 8.4 3.8 4.9 0.8 7.2 2.6 299 5 305 165 11 0 11.1 10.9 08/05/2006 03:20:00 6.4 0.8 8 4.2 6.4 0.8 8 3.8 5.1 0.8 7.2 3 301 6 301 165 11.1 0 11.1 10.9 08/05/2006 03:30:00 6.6 0.9 8.8 4.6 6.6 0.8 8.4 4.9 5.1 1 8 2.6 296 7 295 165 11.1 0 11.1 10.9 08/05/2006 03:40:00 7.9 1.1 10.7 4.6 7.8 1 10.3 4.9 6.3 1 8.8 3.8 294 5 293 165 11.1 0 11.4 10.9 08/05/2006 03:50:00 8.1 1.2 10.7 5.3 8 1.2 10.7 5.3 6.4 1.3 9.9 2.6 298 6 302 165 11.1 0 11.4 10.9 08/05/2006 04:00:00 6.7 0.9 9.1 4.6 6.6 0.9 9.1 4.6 5.3 0.9 8 3.4 300 7 295 165 11.3 0 11.4 10.6 08/05/2006 04:10:00 6.5 1 9.5 4.6 6.4 1 9.1 4.2 5.2 1 8 3 306 7 314 165 11.2 0 11.4 10.9 08/05/2006 04:20:00 8.3 1.1 11.1 5.3 8.2 1.1 11.1 5.3 6.6 1 9.5 4.6 303 6 305 165 11.1 0 11.4 10.9 08/05/2006 04:30:00 7.4 1.2 10.3 4.6 7.3 1.1 10.3 4.6 6.1 1.2 9.5 2.6 306 7 303 165 11 0 11.4 10.6 08/05/2006 04:40:00 8.3 1 10.7 5.7 8.2 1 11.1 6.1 6.5 1.1 9.5 3.4 300 8 302 165 10.8 0.1 11.1 10.3 08/05/2006 04:50:00 5.8 1.3 9.1 2.3 5.9 1.3 8.8 2.3 4.1 1.2 7.2 1.1 293 15 292 165 10.7 0 10.9 10.3 08/05/2006 05:00:00 5.7 1.2 9.1 2.6 5.7 1.2 9.1 2.6 4.1 1.6 8.4 0.7 291 13 281 165 10.7 0 10.9 10.3 08/05/2006 05:10:00 5.1 1.9 8.4 0.4 5 2 8.4 0.4 3.3 1.7 7.2 0.4 297 22 291 165 10.8 0 11.1 10.3 08/05/2006 05:20:00 7 1.2 9.5 4.2 7 1.2 9.5 3.8 5 1.4 8.4 1.5 300 10 319 165 10.9 0 11.1 10.6 08/05/2006 05:30:00 6 1.8 9.1 0.4 6 1.8 9.5 0.4 4.1 1.7 8 0.7 287 28 303 165 11.1 0 11.4 10.9 08/05/2006 05:40:00 7.2 1.3 9.9 2.6 7.2 1.2 9.9 3.4 5.5 1.3 8.8 2.3 297 12 303 165 11.3 0 11.4 10.9 08/05/2006 05:50:00 7 2 11.5 2.6 7 2 11.5 2.6 5.4 1.3 9.1 2.3 305 13 304 165 11.3 0 11.4 11.1 08/05/2006 06:00:00 5.1 1.4 9.5 2.3 5 1.5 9.5 1.9 4.8 1.3 8.8 1.5 320 17 294 165 11.3 0 11.4 11.1 08/05/2006 06:10:00 4.2 1.3 7.6 0.7 4.1 1.4 7.2 0.4 3.9 1.1 6.5 0.7 312 21 316 165 11.7 0.1 11.9 11.4 08/05/2006 06:20:00 3.4 1.5 6.8 0.4 3.3 1.5 6.5 0.4 3 1.3 6.8 0.4 310 22 300 165 12 0.2 12.2 11.4 08/05/2006 06:30:00 5.5 1.3 7.6 2.6 5.8 1.1 8.4 3.4 5.7 1.1 8.4 3 276 11 304 165 11.7 0.2 12.2 11.1 08/05/2006 06:40:00 7.3 1 9.9 4.9 7.5 0.9 9.9 5.7 7.4 0.8 10.3 5.3 281 7 280 165 11.5 0 11.9 11.1 08/05/2006 06:50:00 7.4 0.6 8.8 6.1 7.4 0.5 8.8 6.1 5.6 0.8 8.8 4.2 298 3 290 165 11.5 0 11.7 10.9 08/05/2006 07:00:00 6.5 0.7 8.4 4.9 6.5 0.7 8.4 4.9 5 0.7 6.5 3 296 5 298 165 11.5 0.1 11.7 10.9 08/05/2006 07:10:00 5.8 0.6 7.2 4.6 5.8 0.6 7.2 4.2 4.9 0.7 6.8 2.6 292 5 300 165 11.5 0.1 11.7 11.1 08/05/2006 07:20:00 6 0.4 6.8 4.2 6 0.4 7.2 4.2 5.7 0.6 7.2 4.2 287 4 281 165 11.6 0 11.9 11.4 08/05/2006 07:30:00 6.1 0.4 7.2 5.3 6.2 0.4 7.2 5.3 5.3 0.7 7.2 3.4 291 3 289 165 11.7 0 11.9 11.4 08/05/2006 07:40:00 6.1 0.4 7.2 5.3 6.2 0.4 7.2 5.3 5.3 0.7 7.2 3.4 291 3 293 165 11.7 0 11.9 11.4 08/05/2006 07:50:00 5.8 0.4 6.8 4.9 5.9 0.4 6.8 4.9 5.1 0.7 6.5 3.4 291 4 288 165 11.9 0 12.2 11.7 08/05/2006 08:00:00 6.3 0.5 7.2 4.9 6.4 0.5 7.2 4.9 5.8 0.6 7.6 3.8 289 4 289 165 12.3 0.1 12.7 11.9 08/05/2006 08:10:00 6 0.5 7.2 4.6 6 0.6 7.2 4.6 4.8 0.6 6.5 3 296 5 296 165 12.7 0 13 12.7 08/05/2006 08:20:00 3.9 1.2 6.5 1.5 3.7 1.4 6.5 0.7 3.5 0.8 5.3 1.5 320 23 310 165 13.5 0.1 13.8 13 08/05/2006 08:30:00 1.7 0.5 3.4 0.4 1.4 0.6 3.4 0.4 2.1 0.6 3.8 0.4 10 23 35 165 13.4 0 14.4 13 08/05/2006 08:40:00 1.2 0.6 3 0.4 1 0.6 2.6 0.4 1.5 0.7 3.4 0.4 341 30 11 165 13.7 0.2 14.1 13.3 08/05/2006 08:50:00 0.6 0.3 1.5 0.4 0.5 0.3 1.5 0.4 0.9 0.4 1.9 0.4 305 17 310 165 13.3 0.1 13.8 13 08/05/2006 09:00:00 0.6 0.5 2.3 0.4 0.5 0.4 1.9 0.4 0.8 0.6 2.6 0.4 169 86 118 165 13.4 0 13.5 13.3 08/05/2006 09:10:00 1.5 1.1 4.6 0.4 1.6 1.2 4.6 0.4 1.6 1.2 4.2 0.4 256 90 298 165 13.2 0 13.5 13 08/05/2006 09:20:00 2.3 1.1 4.6 0.4 2.6 1.2 4.6 0.4 2.8 1.1 4.6 0.4 265 22 272 165 13.5 0 13.8 13.3 08/05/2006 09:30:00 1.5 0.9 3.8 0.4 1.4 1 4.2 0.4 1.5 0.8 3 0.4 281 69 291 165 14.2 0.3 14.6 13.5 08/05/2006 09:40:00 0.9 0.5 2.3 0.4 0.7 0.5 1.9 0.4 0.9 0.5 2.3 0.4 115 28 165 165 14.1 0 14.6 14.1 08/05/2006 09:50:00 0.8 0.5 2.3 0.4 0.7 0.5 2.6 0.4 1.1 0.6 2.3 0.4 130 24 128 165 14.4 0.2 15.2 14.1 08/05/2006 10:00:00 2.1 1.4 6.5 0.4 2 1.5 7.2 0.4 2.2 1.3 6.5 0.4 227 79 176 165 15.9 0.5 16.8 15.2 08/05/2006 10:10:00 2.2 0.9 4.9 0.4 2.1 1 5.3 0.4 2.2 1 4.9 0.4 209 69 192 165 16.2 0.1 16.8 15.7 08/05/2006 10:20:00 1.2 0.6 3.4 0.4 1.1 0.6 2.6 0.4 1.4 0.7 3 0.4 158 49 170 165 15.9 0.2 16.3 15.7 08/05/2006 10:30:00 1 0.6 2.6 0.4 0.8 0.6 2.3 0.4 0.9 0.6 2.6 0.4 183 76 63 165 16.1 0 16.3 16 08/05/2006 10:40:00 1.5 0.6 3 0.4 1.5 0.6 3 0.4 1.6 0.6 3 0.4 148 29 168 165 15.7 0.3 16.3 15.2 08/05/2006 10:50:00 1.5 0.6 3 0.4 1.3 0.6 3 0.4 2 0.5 3 0.7 156 15 143 165 15.4 0 15.7 15.2 08/05/2006 11:00:00 1.7 0.6 3.4 0.4 1.5 0.6 3 0.4 2.1 0.5 3.4 0.7 168 15 171 165 15.5 0.1 16 15.2 08/05/2006 11:10:00 2.2 0.5 3.4 1.1 2 0.5 3.4 0.7 2.4 0.5 3.8 1.1 177 16 171 165 15.4 0.1 16 15.2 08/05/2006 11:20:00 2.7 0.7 4.2 0.7 2.6 0.8 4.2 0.4 3 0.6 4.2 1.5 155 14 153 165 15.5 0.3 16.3 15.2 08/05/2006 11:30:00 2.4 0.6 3.8 0.4 2.3 0.6 3.8 0.4 2.7 0.5 4.2 1.1 146 13 153 165 14.9 0.1 15.2 14.6 08/05/2006 11:40:00 2.3 0.5 3.4 0.7 2 0.6 3.8 0.4 2.4 0.5 3.8 1.1 150 17 154 165 15.4 0.1 15.7 14.9 08/05/2006 11:50:00 1.7 0.6 3.8 0.4 1.5 0.6 3.4 0.4 2.2 0.5 3.8 1.5 133 17 133 165 14.8 0.3 15.7 14.6 08/05/2006 12:00:00 2.1 0.6 3.8 0.7 1.9 0.6 3.4 0.4 2.5 0.5 4.2 1.5 135 12 135 165 14.6 0.3 15.5 14.1 08/05/2006 12:10:00 1.5 0.5 2.6 0.4 1.3 0.5 2.3 0.4 1.8 0.4 2.6 0.7 152 22 157 165 13.8 0 14.1 13.3 08/05/2006 12:20:00 1.2 0.6 3 0.4 1.1 0.6 2.6 0.4 1.7 0.6 2.6 0.4 102 14 104 165 14 0 14.4 13.8 08/05/2006 12:30:00 0.8 0.5 2.3 0.4 0.6 0.4 1.9 0.4 1.3 0.5 2.6 0.4 121 19 114 165 14.3 0 14.6 14.1 08/05/2006 12:40:00 0.9 0.5 2.6 0.4 0.7 0.5 2.3 0.4 1.3 0.6 2.6 0.4 113 13 125 165 14.3 0.1 14.9 14.1 08/05/2006 12:50:00 0.7 0.4 1.9 0.4 0.5 0.3 1.9 0.4 1.2 0.6 2.6 0.4 118 18 148 165 15.3 0 15.7 14.9 08/05/2006 13:00:00 1.3 0.8 3.4 0.4 1 0.8 3.4 0.4 1.7 0.6 3.4 0.4 127 21 143 165 15.9 0 16.3 15.7 08/05/2006 13:10:00 1.7 0.6 3 0.4 1.5 0.7 2.6 0.4 2 0.5 3.4 0.7 124 12 153 165 15.2 0.2 15.7 14.6 08/05/2006 13:20:00 2.2 0.3 3 1.1 2.1 0.4 2.6 1.1 2.2 0.4 3 0.4 121 5 121 165 14.6 0 14.9 14.4 08/05/2006 13:30:00 1.9 0.4 3 1.1 1.8 0.5 3 0.7 2.1 0.4 3 1.1 119 8 113 165 14.5 0 15.2 14.4 08/05/2006 13:40:00 2.1 0.3 2.6 1.1 1.9 0.3 2.6 1.1 2.1 0.4 2.6 0.7 122 10 116 165 14.4 0 14.6 14.1 08/05/2006 13:50:00 2.1 0.4 3 0.7 2 0.4 3 0.7 2.3 0.3 3.4 1.5 123 10 139 165 15.2 0.2 15.7 14.6 08/05/2006 14:00:00 2.4 0.4 3 0.4 2.4 0.4 3 0.4 2.5 0.4 3 0.7 112 4 111 165 14.8 0.4 16 14.6 08/05/2006 14:10:00 1.4 0.5 3 0.4 1.1 0.6 3 0.4 1.6 0.4 2.6 0.4 136 17 136 165 15.9 0 16.3 15.7 08/05/2006 14:20:00 1.3 0.4 3 0.4 1.2 0.5 2.6 0.4 1.7 0.4 3 0.7 140 15 160 165 15.4 0.3 16 14.6 08/05/2006 14:30:00 0.8 0.4 1.9 0.4 0.5 0.3 1.5 0.4 1.1 0.5 2.3 0.4 146 13 156 165 15.1 0.6 16.3 14.4 08/05/2006 14:40:00 1.7 0.5 3 0.4 1.4 0.7 3.8 0.4 2 0.6 3.8 0.4 152 17 164 165 16.4 0.2 16.8 16 08/05/2006 14:50:00 2.4 0.6 3.8 0.4 2.3 0.6 4.2 0.4 2.6 0.6 4.6 1.5 145 14 145 165 16 0 16.3 15.7 08/05/2006 15:00:00 2.4 0.5 3.8 1.1 2.3 0.5 4.2 1.1 2.6 0.5 4.2 1.9 146 14 141 165 15.4 0.3 16.3 14.6 08/05/2006 15:10:00 2.7 0.5 4.2 1.5 2.6 0.6 4.2 1.1 2.9 0.5 4.2 1.5 150 9 133 165 15.1 0.2 15.7 14.6 08/05/2006 15:20:00 2.8 0.6 4.2 0.7 2.7 0.6 4.2 0.7 3 0.5 4.6 1.5 140 11 143 165 15.7 0.2 16.3 15.5 08/05/2006 15:30:00 3.2 0.7 4.9 1.1 3.2 0.7 5.3 1.9 3.5 0.6 4.9 1.9 145 14 157 165 16.1 0.2 16.6 15.7 08/05/2006 15:40:00 3.8 0.7 5.7 2.3 3.7 0.7 5.7 1.9 4 0.7 6.5 2.3 146 11 178 165 15.7 0 16 15.2 08/05/2006 15:50:00 3.5 0.5 5.3 1.9 3.5 0.5 4.9 1.9 3.7 0.5 4.9 2.3 143 13 129 165 15.8 0.4 16.6 14.9 08/05/2006 16:00:00 3.6 0.5 4.9 2.3 3.5 0.5 5.3 2.6 3.8 0.5 5.3 2.3 142 9 158 165 16.3 0.2 16.8 15.5 08/05/2006 16:10:00 3.4 0.5 4.9 2.3 3.4 0.5 5.3 1.9 3.6 0.5 4.9 2.3 139 9 153 165 16.4 0.1 16.8 15.7 08/05/2006 16:20:00 3.2 0.5 4.9 1.9 3.3 0.5 4.9 2.3 3.5 0.5 4.9 2.3 144 12 126 165 16.3 0.2 16.8 15.7 08/05/2006 16:30:00 2.8 0.4 3.8 1.9 2.9 0.4 3.8 2.3 3 0.4 4.2 1.9 136 10 153 165 15.2 0.4 16.3 14.6 08/05/2006 16:40:00 2.5 0.4 3.8 1.1 2.7 0.4 3.8 1.5 2.7 0.4 3.8 1.5 131 9 129 165 14.8 0.3 15.7 14.6 08/05/2006 16:50:00 3.2 0.6 5.3 1.9 3.3 0.5 5.3 2.3 3.3 0.6 4.9 1.1 137 12 130 165 15.2 0.4 16.3 14.6 08/05/2006 17:00:00 2.8 0.4 3.8 1.9 3.1 0.4 4.2 2.3 3.1 0.4 3.8 2.3 123 9 112 165 14.8 0 15.7 14.6 08/05/2006 17:10:00 2.5 0.3 3.4 1.9 2.8 0.3 3.8 2.3 2.8 0.3 3.8 2.3 130 5 127 165 15.2 0.2 15.7 14.9 08/05/2006 17:20:00 3.1 0.5 4.2 1.9 3.3 0.5 4.6 2.3 3.3 0.5 4.6 2.3 130 6 133 165 15.8 0.2 16.3 15.2 08/05/2006 17:30:00 3.2 0.4 4.6 2.3 3.3 0.4 4.6 2.6 3.3 0.5 4.6 1.9 134 8 133 165 15.9 0.2 16.3 15.7 08/05/2006 17:40:00 2.7 0.3 3.8 1.9 3 0.3 3.8 2.3 2.9 0.3 3.8 2.3 126 5 113 165 15.7 0 16 15.7 08/05/2006 17:50:00 3 0.4 4.2 2.3 3.2 0.4 4.6 2.3 3.2 0.4 4.6 2.3 131 7 135 165 15.5 0 15.7 15.5 08/05/2006 18:00:00 2.5 0.3 3 1.9 2.8 0.3 3.4 1.9 2.8 0.3 3.8 2.3 124 5 125 165 15.2 0.2 15.7 14.6 08/05/2006 18:10:00 2.7 0.3 3.8 1.9 3 0.3 3.8 2.3 3 0.3 3.8 2.3 121 3 122 165 14.2 0.2 14.9 14.1 08/05/2006 18:20:00 2.9 0.4 3.8 1.9 3.1 0.3 3.8 2.3 3 0.3 3.8 2.3 114 3 107 165 13.9 0 14.4 13.5 08/05/2006 18:30:00 2.7 0.4 3.4 1.9 3 0.4 3.8 2.3 3 0.3 3.8 2.3 116 2 114 165 13.6 0 13.8 13.5 08/05/2006 18:40:00 2.3 0.3 3 1.1 2.6 0.3 3 1.9 2.4 0.4 3 1.1 109 2 109 165 13.7 0 13.8 13.5 08/05/2006 18:50:00 1.7 0.4 2.3 0.4 2 0.4 2.6 0.7 1.7 0.4 2.3 0.7 103 5 104 165 14.6 0.5 15.7 13.8 08/05/2006 19:00:00 1 0.5 2.3 0.4 1.4 0.5 2.3 0.4 1.4 0.4 2.3 0.4 91 1 92 165 15.1 0.1 15.7 14.6 08/05/2006 19:10:00 0.4 0.1 0.7 0.4 0.4 0.2 1.1 0.4 0.6 0.3 1.5 0.4 66 28 73 165 14.8 0 14.9 14.6 08/05/2006 19:20:00 1 0.2 1.5 0.7 0.9 0.4 1.9 0.4 1.7 0.2 2.3 1.1 353 5 350 165 14.6 0 14.9 14.6 08/05/2006 19:30:00 0.7 0.3 1.5 0.4 0.7 0.2 1.5 0.4 1.4 0.3 2.3 0.7 353 5 356 165 15.1 0.1 15.5 14.6 08/05/2006 19:40:00 1 0.4 2.3 0.4 0.9 0.4 1.9 0.4 1.5 0.4 2.3 1.1 355 6 358 165 15.7 0 16 15.5 08/05/2006 19:50:00 0.5 0.3 1.5 0.4 0.5 0.3 1.5 0.4 0.9 0.5 2.3 0.4 6 3 15 165 16.1 0 16.3 16 08/05/2006 20:00:00 0.8 0.4 1.9 0.4 0.9 0.5 1.9 0.4 1.3 0.5 2.3 0.4 348 10 346 165 16.1 0 16.6 16 08/05/2006 20:10:00 0.8 0.2 1.1 0.4 1.1 0.2 1.5 0.7 1.4 0.2 1.9 1.1 345 1 344 165 15.1 0.4 16 14.4 08/05/2006 20:20:00 0.8 0.3 1.5 0.4 1 0.3 1.5 0.4 1.5 0.3 1.9 1.1 351 2 353 165 13.9 0.2 14.6 13.5 08/05/2006 20:30:00 0.5 0.2 1.1 0.4 0.8 0.4 1.5 0.4 1.1 0.4 1.9 0.4 351 2 349 165 13.5 0 13.8 13.3 08/05/2006 20:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0.1 0.7 0.4 352 1 165 165 13.9 0.3 14.4 13.5 08/05/2006 20:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.5 0.2 1.1 0.4 352 1 165 165 14.1 0.1 14.6 13.5 08/05/2006 21:00:00 0.7 0.5 1.9 0.4 0.8 0.7 2.3 0.4 0.7 0.5 2.3 0.4 307 24 290 165 13.7 0 13.8 13.5 08/05/2006 21:10:00 1.3 0.3 1.9 0.7 1.7 0.3 2.3 1.1 1.4 0.5 2.6 0.7 284 1 279 165 13.3 0 13.5 12.7 08/05/2006 21:20:00 0.4 0.1 1.1 0.4 0.5 0.3 1.5 0.4 0.8 0.5 1.9 0.4 281 8 284 165 13.3 0 13.5 12.7 08/05/2006 21:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.6 0.2 1.1 0.4 255 1 165 165 13.5 0 13.8 13.3 08/05/2006 21:40:00 0.4 0.2 1.1 0.4 0.7 0.3 1.5 0.4 0.9 0.4 1.5 0.4 255 1 255 165 13.7 0 13.8 13.5 08/05/2006 21:50:00 1.4 0.3 1.9 0.7 1.8 0.3 2.3 1.1 1.9 0.3 2.3 1.1 271 2 272 165 13.7 0 13.8 13.3 08/05/2006 22:00:00 2.1 0.3 2.6 1.1 2.4 0.3 3 1.9 2.3 0.3 3 1.5 280 5 277 165 13.6 0 13.8 13.3 08/05/2006 22:10:00 2.2 0.5 3 1.1 2.5 0.4 3.4 1.5 2.5 0.5 3.4 1.1 284 3 284 165 13.6 0 13.8 13.3 08/05/2006 22:20:00 3.4 0.4 4.2 2.6 3.6 0.3 4.2 2.6 3.2 0.4 4.2 1.9 286 3 284 165 13.5 0 13.8 13.3 08/05/2006 22:30:00 3.3 0.4 4.6 2.3 3.4 0.4 4.6 2.6 2.7 0.5 3.8 1.9 299 7 308 165 13.3 0 13.8 13 08/05/2006 22:40:00 3.6 0.5 4.6 1.5 3.7 0.4 4.6 2.3 3.6 0.4 4.2 2.6 312 5 310 165 13.2 0 13.3 13 08/05/2006 22:50:00 2.6 0.5 3.8 1.5 2.9 0.4 4.2 1.9 2.7 0.4 3.8 1.9 311 5 307 165 13.4 0 13.5 13.3 08/05/2006 23:00:00 1.6 0.7 3 0.4 2.1 0.6 3.4 0.4 1.9 0.6 3 0.4 291 6 295 165 13.5 0.2 14.1 13 08/05/2006 23:10:00 1.5 0.5 2.6 0.4 2 0.4 3 1.1 1.9 0.5 3 0.7 288 8 284 165 13.9 0 14.1 13.3 08/05/2006 23:20:00 1.9 0.5 3 0.7 2.3 0.4 3.4 1.5 2.1 0.5 3 1.1 312 6 321 165 13.7 0.2 14.6 13.3 08/05/2006 23:30:00 1.3 0.4 2.6 0.4 1.7 0.4 2.6 0.7 1.8 0.4 2.6 1.1 321 7 315 165 13.4 0 13.5 13.3 08/05/2006 23:40:00 0.6 0.4 1.5 0.4 0.8 0.5 1.9 0.4 0.9 0.5 1.9 0.4 322 7 329 165 13.4 0 13.8 13.3 08/05/2006 23:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0.2 1.1 0.4 322 2 165 165 13.7 0 14.1 13.5 08/06/2006 00:00:00 0.4 0.1 0.7 0.4 0.4 0.2 1.1 0.4 0.7 0.2 1.1 0.4 185 76 146 165 13.5 0 13.8 13.5 08/06/2006 00:10:00 0.5 0.2 1.1 0.4 0.6 0.3 1.1 0.4 0.6 0.3 1.1 0.4 140 2 138 165 13.5 0 13.8 13.3 08/06/2006 00:20:00 0.4 0 0.4 0.4 0.4 0.1 0.7 0.4 0.5 0.2 1.1 0.4 150 12 165 165 13.7 0 13.8 13.5 08/06/2006 00:30:00 0.4 0.1 1.1 0.4 0.5 0.3 1.5 0.4 0.5 0.3 1.5 0.4 230 49 290 165 13.7 0 13.8 13.5 08/06/2006 00:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0.2 1.1 0.4 275 2 165 165 13.6 0 13.8 13.3 08/06/2006 00:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 1 102 165 165 13.7 0 13.8 13.5 08/06/2006 01:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 119 1 165 165 13.7 0 13.8 13.5 08/06/2006 01:10:00 0.9 0.6 2.3 0.4 1.2 0.7 2.3 0.4 1.1 0.6 2.3 0.4 1 90 291 165 13.5 0.1 13.8 13 08/06/2006 01:20:00 1.4 0.4 2.3 0.4 1.7 0.4 2.6 0.4 1.8 0.2 2.3 1.1 310 2 310 165 13.5 0.1 13.5 13 08/06/2006 01:30:00 0.5 0.2 1.5 0.4 0.6 0.3 1.5 0.4 1.1 0.4 1.9 0.4 333 13 313 165 13.5 0 13.5 13 08/06/2006 01:40:00 1.3 0.3 1.9 0.7 0.8 0.5 1.9 0.4 1.5 0.3 1.9 1.1 352 7 359 165 13.2 0 13.3 13 08/06/2006 01:50:00 1.7 0.3 2.3 1.1 1.3 0.6 2.6 0.4 1.9 0.3 2.6 1.5 351 3 355 165 12.9 0 13.3 12.7 08/06/2006 02:00:00 1.3 0.5 2.6 0.4 1.5 0.5 2.6 0.4 1.6 0.4 2.6 0.7 325 17 334 165 13.3 0.2 13.5 12.7 08/06/2006 02:10:00 0.9 0.4 1.9 0.4 1.2 0.4 2.3 0.4 1.4 0.3 2.3 0.7 310 10 303 165 13.5 0 13.5 13.3 08/06/2006 02:20:00 1.4 0.5 2.6 0.4 1.4 0.6 3 0.4 1.8 0.3 2.6 1.1 340 12 338 165 13.5 0 13.8 13.3 08/06/2006 02:30:00 2.2 0.4 3.4 1.1 1.7 0.6 3.4 0.4 2.7 0.5 3.8 1.5 4 11 20 165 13.5 0 13.5 13.3 08/06/2006 02:40:00 2.7 0.4 3.8 1.5 2.6 0.7 3.8 0.7 3.1 0.3 3.8 2.3 352 13 340 165 13.7 0 13.8 13.3 08/06/2006 02:50:00 2.5 0.5 3.8 1.1 2.2 0.8 4.2 0.7 2.8 0.4 3.8 1.5 357 14 346 165 13.6 0 13.8 13.5 08/06/2006 03:00:00 1.7 0.7 3.4 0.4 1.6 0.8 3.8 0.4 2.4 0.6 3.8 1.1 350 12 339 165 13.9 0 14.1 13.8 08/06/2006 03:10:00 2 0.7 3.4 0.4 2.2 0.7 3.4 0.4 2.4 0.5 3.4 1.1 337 8 340 165 13.7 0 14.1 13.5 08/06/2006 03:20:00 1.4 0.4 3 0.4 1.5 0.5 2.6 0.4 1.8 0.4 2.6 0.7 337 17 328 165 13.9 0 14.1 13.3 08/06/2006 03:30:00 1.3 0.6 2.6 0.4 1.5 0.8 3 0.4 1.9 0.7 3 0.4 336 14 344 165 13.9 0.1 14.1 13.3 08/06/2006 03:40:00 2.3 0.5 3.8 1.5 2.6 0.5 3.8 1.5 2.8 0.4 3.8 1.9 340 5 336 165 13.3 0 13.5 13 08/06/2006 03:50:00 2.9 0.3 3.4 2.3 3.1 0.3 3.8 2.3 3.2 0.3 3.8 2.6 338 5 332 165 13.5 0 13.5 13.3 08/06/2006 04:00:00 2 0.8 3.4 0.4 2.1 0.9 3.8 0.4 2.4 0.7 3.8 0.7 338 11 341 165 13.5 0 13.8 13.5 08/06/2006 04:10:00 0.6 0.3 1.5 0.4 0.6 0.4 1.5 0.4 1.1 0.4 1.9 0.4 334 4 328 165 13.6 0 13.8 13.5 08/06/2006 04:20:00 1.2 0.3 1.9 0.4 1.4 0.3 2.3 0.4 1.6 0.3 2.3 0.7 314 8 315 165 13.9 0 14.1 13.8 08/06/2006 04:30:00 1.2 0.4 2.6 0.4 1.4 0.4 2.6 0.7 1.6 0.3 2.3 0.7 315 8 331 165 13.9 0 14.1 13.5 08/06/2006 04:40:00 0.9 0.3 1.5 0.4 0.7 0.4 1.5 0.4 1.4 0.3 1.9 0.7 338 10 325 165 13.7 0 13.8 13.5 08/06/2006 04:50:00 0.7 0.4 1.9 0.4 0.6 0.3 1.5 0.4 1.2 0.5 2.3 0.4 337 12 346 165 13.6 0 13.8 13.5 08/06/2006 05:00:00 0.5 0.3 1.5 0.4 0.5 0.3 1.9 0.4 1 0.3 1.9 0.4 330 17 310 165 13.5 0 13.8 13.5 08/06/2006 05:10:00 0.5 0.3 1.5 0.4 0.5 0.3 1.5 0.4 0.9 0.5 1.9 0.4 286 27 289 165 13.7 0 13.8 13.5 08/06/2006 05:20:00 1.8 0.6 3 0.7 2 0.6 3.4 1.1 2.1 0.5 3 1.1 287 5 292 165 13.7 0 13.8 13.3 08/06/2006 05:30:00 2.1 0.8 3.8 0.7 2.3 0.7 4.2 0.7 2.5 0.6 3.8 1.1 278 5 274 165 13.7 0 13.8 13.5 08/06/2006 05:40:00 0.8 0.5 1.9 0.4 1 0.6 2.3 0.4 1.5 0.5 2.6 0.4 280 7 271 165 13.8 0 13.8 13.5 08/06/2006 05:50:00 0.5 0.3 1.5 0.4 0.5 0.4 1.9 0.4 0.8 0.6 2.6 0.4 263 17 275 165 13.9 0 14.1 13.5 08/06/2006 06:00:00 1 0.5 2.6 0.4 1.4 0.6 2.6 0.4 1.6 0.8 3.8 0.4 259 36 280 165 13.9 0 14.1 13.5 08/06/2006 06:10:00 0.5 0.3 1.5 0.4 0.5 0.2 1.5 0.4 0.4 0.2 1.1 0.4 178 49 122 165 13.4 0 14.4 13.3 08/06/2006 06:20:00 0.5 0.4 2.3 0.4 0.5 0.4 2.3 0.4 0.8 0.6 2.3 0.4 121 12 113 165 13.3 0 13.5 13 08/06/2006 06:30:00 0.4 0 0.7 0.4 0.4 0 0.7 0.4 0.4 0.2 1.1 0.4 8 79 311 165 13.3 0 13.5 13 08/06/2006 06:40:00 0.4 0.1 0.7 0.4 0.4 0.1 0.7 0.4 0.4 0.2 1.1 0.4 308 6 298 165 13 0 13.3 12.7 08/06/2006 06:50:00 2.2 0.9 3.8 0.4 2.4 0.9 3.8 0.4 2 0.9 3.8 0.4 286 9 280 165 13.3 0 13.5 13 08/06/2006 07:00:00 2.4 0.6 3.4 0.7 2.5 0.5 3.8 1.1 2.1 0.5 3.8 1.1 294 7 288 165 13.4 0.1 13.5 13 08/06/2006 07:10:00 2.7 0.9 4.6 0.4 2.8 0.9 4.6 0.4 2.4 0.9 4.2 0.7 290 8 286 165 13.7 0 13.8 13 08/06/2006 07:20:00 3.8 0.5 4.9 2.3 3.9 0.5 4.9 2.6 3.3 0.6 4.6 1.9 293 5 302 165 13.9 0 14.1 13.8 08/06/2006 07:30:00 4.1 0.6 5.3 1.9 4.2 0.6 5.3 2.3 3.6 0.8 6.1 1.5 294 8 299 165 14.2 0 14.6 14.1 08/06/2006 07:40:00 5 0.6 6.1 3.4 5 0.6 6.5 3.4 4.4 0.7 6.1 2.6 293 4 294 165 14.8 0.3 15.5 14.6 08/06/2006 07:50:00 5.6 0.5 6.5 3.8 5.6 0.5 6.5 4.2 4.8 0.7 6.5 3.4 294 5 291 165 15.5 0 15.7 15.2 08/06/2006 08:00:00 5.2 0.6 6.5 3.8 5.2 0.6 6.5 3.8 4.5 0.7 6.1 3 294 6 295 165 15.8 0.1 16.3 15.5 08/06/2006 08:10:00 4.7 0.5 6.1 3.4 4.7 0.5 6.1 3 3.9 0.8 5.7 2.3 297 8 288 165 16.4 0.3 17.1 16 08/06/2006 08:20:00 4.9 0.7 6.8 3.4 4.9 0.8 6.5 3 4.3 0.7 6.5 2.6 305 6 300 165 16.9 0.1 17.4 16.6 08/06/2006 08:30:00 6 0.8 8.4 3.8 6 0.7 8.4 4.2 4.9 0.8 8 2.3 304 6 310 165 16.4 0.1 16.8 16.3 08/06/2006 08:40:00 5.7 0.7 7.2 3.8 5.6 0.7 7.2 4.2 4.6 0.7 6.5 2.3 302 6 310 165 16.3 0.1 16.8 16.3 08/06/2006 08:50:00 6.2 0.6 7.2 4.6 6.1 0.6 7.2 4.2 4.8 0.6 6.5 3.4 300 5 300 165 16.2 0.1 16.8 15.7 08/06/2006 09:00:00 6 0.5 7.2 4.9 5.9 0.5 7.6 4.9 4.6 0.5 7.2 3 301 5 306 165 16.2 0.1 16.6 16 08/06/2006 09:10:00 5.6 0.7 7.2 3.4 5.5 0.7 6.8 2.6 4.5 0.8 7.2 2.6 298 9 294 165 16.3 0 16.6 16.3 08/06/2006 09:20:00 5.2 0.7 7.2 3.8 5.1 0.7 7.2 3.8 4.2 0.8 7.2 2.6 298 8 280 165 16.9 0.2 17.4 16.6 08/06/2006 09:30:00 5.5 1.1 8.4 3.8 5.6 1.1 8.4 3.8 4.7 1.4 8.4 2.3 293 9 277 165 17 0 17.1 16.8 08/06/2006 09:40:00 6 1.1 8.8 2.6 6 1.1 8.4 2.6 4.7 1.1 7.6 1.5 297 10 298 165 17.5 0.6 18.5 16.8 08/06/2006 09:50:00 5.6 1.1 8 3 5.7 1 8 3 4.7 1 7.2 2.3 293 8 292 165 18.1 0 18.5 17.4 08/06/2006 10:00:00 5 1.1 7.2 1.1 5 1.1 7.2 1.9 4.2 1 6.5 1.9 294 9 289 165 18.1 0 18.5 17.7 08/06/2006 10:10:00 5.5 1 7.6 2.3 5.5 1 7.6 2.6 4.5 1 6.8 2.3 296 9 299 165 18 0.2 18.5 17.4 08/06/2006 10:20:00 4.5 0.9 6.5 1.9 4.7 0.8 6.5 1.9 3.7 1 6.5 1.1 295 10 289 165 18.5 0.4 19.4 17.4 08/06/2006 10:30:00 3.9 1.3 6.1 0.4 4.2 1.2 6.1 0.7 3.4 1.2 6.1 0.4 291 16 289 165 18 0.2 18.5 17.4 08/06/2006 10:40:00 3.7 1 6.1 0.4 3.8 0.9 6.1 0.4 2.6 0.9 4.9 0.4 295 13 295 165 18 0 18.2 17.7 08/06/2006 10:50:00 3.7 0.5 5.3 2.3 3.9 0.5 5.7 2.6 3 0.6 4.9 1.5 295 9 285 165 17.7 0.3 18.2 17.1 08/06/2006 11:00:00 3.7 0.8 5.7 1.9 4 0.7 6.1 2.3 3.5 0.7 5.7 1.9 289 9 296 165 18.7 0.2 19.1 18.2 08/06/2006 11:10:00 5.6 0.7 7.6 3.8 5.7 0.6 7.6 4.2 4.6 0.8 6.8 2.6 295 7 294 165 18.2 0.7 19.4 17.1 08/06/2006 11:20:00 4 0.9 6.1 1.9 4.2 0.9 6.5 1.9 3.3 1 5.7 0.7 291 12 314 165 17.4 0.7 19.1 16.6 08/06/2006 11:30:00 4.5 0.7 6.5 2.6 4.7 0.6 6.5 3.4 3.7 0.8 5.7 1.9 293 9 289 165 19.2 0 19.7 18.8 08/06/2006 11:40:00 4.4 0.8 6.5 2.3 4.7 0.7 6.8 2.6 3.5 1 6.1 0.7 299 8 311 165 19 0.3 19.7 18.5 08/06/2006 11:50:00 5.1 0.9 7.2 2.6 5.2 0.9 7.6 2.6 4.1 1 6.1 1.9 301 11 296 165 19.9 0.3 20.5 19.1 08/06/2006 12:00:00 4.9 1.1 7.2 1.5 5.1 1 7.2 1.9 4.1 1.1 6.8 1.5 298 9 291 165 20.2 0.2 20.8 19.7 08/06/2006 12:10:00 5.7 0.7 8.4 3.8 5.8 0.7 8.4 3.8 4.7 0.8 6.8 2.3 300 9 300 165 20.2 0.3 21.1 19.7 08/06/2006 12:20:00 6.4 0.7 8.4 4.2 6.5 0.7 8.8 4.2 5.3 0.7 6.8 3 302 7 302 165 20 0.2 20.8 19.7 08/06/2006 12:30:00 5.3 0.8 7.2 3 5.5 0.8 7.2 3.4 4.6 1 7.2 2.3 308 10 308 165 20.2 0.4 21.1 19.7 08/06/2006 12:40:00 5.7 0.9 7.6 2.6 5.8 0.9 8.4 3 4.8 1 7.2 2.3 304 9 317 165 20.3 0.2 21.1 20 08/06/2006 12:50:00 5.9 0.9 8.4 3.4 6 0.8 8.4 3.8 4.8 0.8 7.2 2.6 306 7 307 165 20 0.2 20.8 19.4 08/06/2006 13:00:00 6 1.1 9.1 3.4 6 1 9.1 3.8 5 1 8.8 2.6 304 9 297 165 19.7 0.2 20.8 19.1 08/06/2006 13:10:00 6.2 1 8 3.8 6.2 0.9 8.4 4.2 4.9 0.9 8 3 302 8 299 165 20 0 20.5 19.7 08/06/2006 13:20:00 6.3 0.8 8 4.2 6.4 0.7 8.4 4.6 5.1 0.8 7.6 3 297 6 318 165 19.7 0.2 20.5 19.7 08/06/2006 13:30:00 5.8 0.8 7.6 3.4 5.9 0.7 8 3.4 4.9 0.8 6.8 3 304 10 289 165 20.2 0.3 20.8 19.4 08/06/2006 13:40:00 5.4 0.9 7.6 3 5.5 0.9 7.6 3 4.6 1 6.8 2.3 303 11 309 165 20.7 0.2 21.7 20.5 08/06/2006 13:50:00 5.2 1 7.2 2.3 5.4 1 7.6 2.6 4.4 1 6.8 1.9 295 9 300 165 20.5 0 21.1 20 08/06/2006 14:00:00 6.2 1 8.4 3.4 6.3 1 9.1 3.8 5.4 1 8 3.4 306 10 305 165 20.8 0.2 21.4 20.2 08/06/2006 14:10:00 6.1 1 8.4 2.6 6.1 1 8.4 3 5.7 1 8 3 316 8 307 165 20.8 0.3 21.4 20.2 08/06/2006 14:20:00 5.8 1 8 3.4 6 0.9 8.4 3.4 4.9 0.9 7.2 1.9 305 9 302 165 20.4 0.4 21.1 19.7 08/06/2006 14:30:00 5.4 0.9 8 3 5.5 0.8 8 3 4.7 0.8 7.2 3 301 12 305 165 20.5 0.4 21.1 19.7 08/06/2006 14:40:00 5.6 1.2 8.4 3 5.7 1.1 8 3.4 4.7 1 7.6 2.3 299 9 299 165 20.6 0.3 21.1 20 08/06/2006 14:50:00 5.6 1.1 8.4 3.4 5.8 1 8.4 3.4 4.8 1 8 2.3 303 10 301 165 20.5 0.4 21.4 19.7 08/06/2006 15:00:00 6.6 1 8.8 4.2 6.7 1 8.8 4.2 5.5 1 7.6 3 298 8 315 165 20.4 0.2 21.1 20 08/06/2006 15:10:00 6.9 1 9.1 4.6 6.9 0.9 9.1 4.9 5.8 1 8 3.4 306 8 302 165 20.1 0.2 20.8 19.7 08/06/2006 15:20:00 6.1 1.3 8.8 3 6.2 1.3 8.8 3 5.2 1.1 7.6 2.3 307 9 299 165 20.2 0.2 20.8 19.7 08/06/2006 15:30:00 6.7 0.9 8.8 4.2 6.7 0.8 8.8 4.6 5.5 1 8 3 306 7 312 165 20.7 0.1 21.1 20.2 08/06/2006 15:40:00 6.9 0.9 8.8 2.6 6.8 0.9 8.8 3.4 6.2 1 8.4 2.6 310 6 313 165 20 0 20.5 20 08/06/2006 15:50:00 6.6 0.9 9.1 4.6 6.6 0.9 9.1 4.6 5.9 0.9 9.1 3.8 310 7 305 165 20.4 0 20.8 20 08/06/2006 16:00:00 7.5 0.7 9.1 5.3 7.5 0.7 9.1 5.3 6.1 0.8 8 4.2 306 6 314 165 20 0.3 20.8 19.7 08/06/2006 16:10:00 7 0.7 8.8 4.6 6.9 0.7 8.8 4.6 5.9 1 8.8 3.8 303 8 314 165 19.7 0 20 19.7 08/06/2006 16:20:00 7.3 0.7 9.5 5.3 7.2 0.7 9.1 5.3 6 0.8 8.4 4.2 301 8 302 165 19.5 0 19.7 19.1 08/06/2006 16:30:00 7.4 0.7 9.5 5.3 7.4 0.7 9.9 5.3 6.1 1 9.5 3.8 299 7 309 165 19.2 0 19.4 18.8 08/06/2006 16:40:00 7.5 0.9 9.9 5.3 7.4 1 10.3 4.9 6.1 1 9.1 3.8 305 8 302 165 19.2 0 19.7 18.8 08/06/2006 16:50:00 6.9 1 9.5 4.2 6.9 1 9.5 4.2 5.6 1 8.4 3.8 304 7 308 165 19.5 0.1 19.7 19.1 08/06/2006 17:00:00 7.4 0.7 9.9 5.7 7.4 0.7 10.3 5.7 6.1 1 9.5 4.2 295 6 295 165 19.2 0 19.4 19.1 08/06/2006 17:10:00 6.8 0.9 8.8 4.2 6.8 0.8 8.8 4.6 5.6 0.8 8.4 3 302 8 300 165 19.3 0.1 19.7 19.1 08/06/2006 17:20:00 7.4 1.2 11.5 4.9 7.4 1.2 11.5 4.9 6.2 1.1 10.7 3.8 305 10 307 165 19.5 0 19.7 19.1 08/06/2006 17:30:00 7.6 0.8 9.9 4.9 7.5 0.9 9.9 4.9 6.3 1 8.8 4.2 307 7 297 165 19.2 0 19.4 19.1 08/06/2006 17:40:00 7.8 0.6 9.1 4.9 7.7 0.6 9.1 4.9 6.1 0.7 8.4 4.2 299 6 296 165 19.2 0.1 19.4 18.8 08/06/2006 17:50:00 7.9 0.8 9.9 5.3 7.8 0.8 9.9 5.3 6.3 0.8 8.4 4.2 302 8 306 165 19 0 19.4 18.8 08/06/2006 18:00:00 8 0.7 9.9 6.1 7.9 0.8 9.9 5.7 6.5 0.9 9.1 4.2 304 6 300 165 19 0 19.4 18.8 08/06/2006 18:10:00 8 0.7 9.5 6.1 8 0.7 9.5 6.1 6.2 0.7 8.4 4.6 301 6 302 165 18.7 0 19.1 18.5 08/06/2006 18:20:00 8.2 0.6 9.5 6.5 8.2 0.6 9.5 6.8 6.2 0.7 8.8 4.2 299 5 300 165 18.6 0.1 18.8 18.5 08/06/2006 18:30:00 8.4 0.8 10.3 6.5 8.3 0.9 10.3 6.1 6.9 0.9 9.1 4.6 306 7 295 165 18.5 0 18.8 18.2 08/06/2006 18:40:00 8 0.8 9.9 6.1 7.9 0.9 9.9 6.1 6.7 1 9.1 4.2 305 7 308 165 18.4 0 18.5 18.2 08/06/2006 18:50:00 8 1 9.9 6.1 7.9 1 9.9 6.1 7 1 10.3 4.6 310 5 308 165 18.2 0 18.8 18 08/06/2006 19:00:00 9.3 0.8 11.1 7.6 9.2 0.8 11.1 7.2 7.9 1 9.9 5.3 308 5 305 165 18 0.1 18.5 17.7 08/06/2006 19:10:00 9.7 1 11.8 7.2 9.6 1 12.2 7.2 8.4 0.8 9.9 6.1 310 5 309 165 17.9 0 18 17.7 08/06/2006 19:20:00 10 0.8 12.6 8 9.9 0.9 12.2 7.6 8.4 0.9 11.1 6.1 308 4 301 165 17.5 0 18 17.4 08/06/2006 19:30:00 10.4 1 12.6 8.4 10.4 0.9 12.6 8 8.2 0.8 10.3 6.5 306 4 305 165 17.3 0 17.7 17.1 08/06/2006 19:40:00 10.8 1 13 7.6 10.8 1 12.6 8 8.3 0.8 10.3 6.1 304 5 304 165 17.1 0 17.4 16.8 08/06/2006 19:50:00 10.6 1.1 13.3 8 10.5 1.1 13 8 8.3 1.1 12.2 5.7 303 6 294 165 16.8 0 17.1 16.8 08/06/2006 20:00:00 10.8 1.1 13.3 8 10.7 1.1 13.3 8.4 8.8 1.1 12.6 6.1 304 6 304 165 16.8 0 16.8 16.6 08/06/2006 20:10:00 10.8 1.1 13.7 7.6 10.6 1.1 13.3 7.6 9.1 1.2 12.2 4.9 308 7 303 165 16.6 0 16.8 16.6 08/06/2006 20:20:00 10.1 1.2 13 6.8 9.9 1.3 13 6.5 8.6 1.1 11.8 4.9 310 8 305 165 16.4 0.1 16.8 16.3 08/06/2006 20:30:00 9.7 1.2 13.3 5.7 9.6 1.2 13.3 5.7 8.1 1.2 11.5 5.3 307 8 299 165 16.2 0 16.6 16.3 08/06/2006 20:40:00 10 1.1 13 6.5 9.8 1.1 12.2 5.7 8.1 1 11.1 4.9 306 7 303 165 15.9 0 16.3 15.7 08/06/2006 20:50:00 8.5 1.3 12.6 5.3 8.5 1.3 13 4.9 7.1 1.1 10.3 4.2 310 9 313 165 15.4 0.2 16 15.2 08/06/2006 21:00:00 9.7 1.1 12.2 6.5 9.6 1.1 12.2 6.8 7.9 1.3 13 4.6 307 7 308 165 15.2 0 15.5 15.2 08/06/2006 21:10:00 9.5 1.2 12.6 6.5 9.4 1.1 12.2 6.5 7.6 1.2 10.7 4.6 306 7 301 165 15.1 0 15.5 15.2 08/06/2006 21:20:00 9.8 1.2 12.6 6.8 9.6 1.2 13 6.5 7.6 1.3 11.1 4.6 304 8 300 165 15 0 15.2 14.9 08/06/2006 21:30:00 9.2 1.1 12.6 6.5 9.1 1.1 12.6 6.1 7.1 1.2 9.9 3.8 306 6 291 165 15 0 15.2 14.9 08/06/2006 21:40:00 8.8 1.2 12.2 5.7 8.7 1.3 12.2 5.3 6.9 1.2 10.3 3.4 308 7 296 165 14.8 0 15.2 14.6 08/06/2006 21:50:00 8.2 1.2 11.5 4.6 8.1 1.2 11.1 4.6 6.6 1.3 9.5 3.4 310 10 300 165 14.8 0 15.2 14.6 08/06/2006 22:00:00 7.6 1 9.9 4.9 7.4 1.1 10.3 4.6 6.7 1.1 9.5 3.4 317 10 307 165 14.6 0 14.9 14.4 08/06/2006 22:10:00 8.5 1.2 11.8 5.3 8.3 1.2 11.5 4.9 7 1.1 11.5 4.2 314 10 315 165 14.8 0 14.9 14.6 08/06/2006 22:20:00 9.6 1.4 14.1 6.1 9.6 1.3 13.7 6.1 8 1.4 12.6 4.9 310 8 319 165 14.7 0.1 15.2 14.6 08/06/2006 22:30:00 10.5 1.2 14.1 6.5 10.3 1.2 13.7 6.1 8.6 1.1 11.5 5.7 308 7 302 165 15.2 0.1 15.7 15.2 08/06/2006 22:40:00 10.8 1.2 14.1 8 10.6 1.2 13.3 7.2 9.2 1.1 12.2 6.5 309 6 302 165 15 0.1 15.2 14.9 08/06/2006 22:50:00 12.1 1.2 14.9 8.4 11.8 1.1 14.1 8.4 9.6 1 11.8 7.2 305 6 299 165 15.2 0 15.5 15.2 08/06/2006 23:00:00 11.5 1.3 14.9 8 11.3 1.3 14.5 7.2 9 1.1 13.3 5.7 302 6 302 165 15.2 0 15.5 15.2 08/06/2006 23:10:00 9.9 1.5 13.7 6.1 9.8 1.5 13.7 6.1 7.7 1.5 11.1 3 302 7 297 165 15.2 0 15.5 15.2 08/06/2006 23:20:00 9.9 1.2 12.6 6.5 9.7 1.2 12.2 6.1 7.6 1.3 11.1 4.2 303 7 304 165 15.1 0 15.2 14.9 08/06/2006 23:30:00 10.5 1.3 14.9 7.6 10.3 1.3 14.1 6.8 8.2 1.3 11.5 4.6 303 6 299 165 15.1 0 15.5 14.9 08/06/2006 23:40:00 11.5 1.2 14.9 8 11.3 1.2 14.5 8 9.1 1.2 12.2 6.1 304 7 296 165 15.3 0 15.7 15.2 08/06/2006 23:50:00 11.5 1.4 16.1 7.2 11.4 1.3 15.6 6.8 9 1.2 12.2 5.3 303 6 304 165 15.4 0 15.7 15.2 08/07/2006 00:00:00 11.1 1.1 14.5 8.4 10.9 1.1 14.1 8 8.8 1.1 11.5 5.7 303 6 295 165 15.2 0 15.5 15.2 08/07/2006 00:10:00 10.6 1.4 14.1 6.8 10.5 1.3 13.7 6.8 8.4 1.2 11.8 5.3 303 7 306 165 15.1 0 15.5 15.2 08/07/2006 00:20:00 8.5 1.5 11.8 4.2 8.4 1.5 12.2 4.6 7.1 1.2 9.9 4.2 314 11 306 165 14.7 0.1 15.2 14.6 08/07/2006 00:30:00 9.1 1.2 11.8 4.9 9 1.2 11.8 4.9 7.7 1.1 10.7 4.2 311 9 316 165 14.6 0 14.9 14.6 08/07/2006 00:40:00 9.8 1.3 12.6 5.7 9.6 1.3 12.6 5.7 7.9 1.1 11.5 4.9 305 8 297 165 14.9 0.1 15.2 14.6 08/07/2006 00:50:00 9.5 1.2 13 6.1 9.3 1.2 13 6.1 7.9 1.1 11.1 4.9 308 9 307 165 14.8 0 15.2 14.6 08/07/2006 01:00:00 9.1 1.1 11.8 6.1 9 1.1 11.8 6.5 7.5 1.1 10.3 4.9 307 9 306 165 14.6 0 14.9 14.6 08/07/2006 01:10:00 8.5 1.5 12.2 4.6 8.4 1.4 11.8 4.9 7.3 1.3 11.5 4.6 311 11 308 165 14.6 0 14.9 14.4 08/07/2006 01:20:00 10.2 1.2 13.3 6.8 10 1.2 13.3 6.8 8.2 1.1 11.5 4.2 306 9 296 165 14.8 0 15.2 14.6 08/07/2006 01:30:00 10.9 1.3 13.7 6.8 10.8 1.3 13.3 6.5 8.5 1.2 12.6 5.7 303 6 302 165 15.2 0 15.5 14.9 08/07/2006 01:40:00 10.4 1.2 13.3 6.8 10.3 1.2 13 6.8 8.1 1.1 11.8 4.6 303 7 305 165 15.2 0.1 15.5 15.2 08/07/2006 01:50:00 10.5 1.1 12.6 7.6 10.4 1 12.6 7.6 8.2 1.2 12.6 5.7 302 7 301 165 15.2 0 15.5 15.2 08/07/2006 02:00:00 10.1 1.1 13.3 7.2 10 1.1 13 6.8 8.3 1.1 12.6 5.7 304 7 317 165 15.2 0 15.5 15.2 08/07/2006 02:10:00 9.2 1.2 12.2 5.7 9.1 1.2 12.6 5.3 7.6 1.2 12.6 4.6 306 7 305 165 15.1 0.1 15.7 14.6 08/07/2006 02:20:00 9.6 1.1 13.3 7.2 9.5 1.1 13.3 6.8 7.4 1 10.7 5.3 303 6 302 165 15.2 0 15.7 14.6 08/07/2006 02:30:00 10.2 1 13 8.4 10.1 1 12.6 7.6 8 1 10.7 5.3 304 5 307 165 15.2 0 15.5 14.9 08/07/2006 02:40:00 10.2 1 13 7.6 10.2 1 12.6 7.6 7.9 0.9 10.7 5.7 302 6 311 165 15.3 0 15.5 14.9 08/07/2006 02:50:00 9.3 1.2 12.2 6.8 9.3 1.2 11.8 6.5 7.5 1.1 10.7 4.9 305 6 302 165 15.3 0 15.7 14.9 08/07/2006 03:00:00 8.8 1.1 11.1 4.9 8.7 1 11.1 5.3 7 1 9.5 4.2 304 6 309 165 15.2 0.1 15.5 14.6 08/07/2006 03:10:00 8.8 0.9 11.5 6.5 8.7 0.9 11.5 6.1 6.8 0.9 9.1 4.9 301 6 290 165 15.2 0.1 15.5 14.6 08/07/2006 03:20:00 8.6 0.9 10.7 5.7 8.5 0.9 10.7 5.3 6.6 0.8 8.4 3.8 302 6 302 165 15.2 0.1 15.7 14.6 08/07/2006 03:30:00 9 0.8 11.5 6.8 9 0.8 11.1 6.8 6.9 0.8 9.5 4.6 299 6 303 165 15.2 0.1 15.5 14.9 08/07/2006 03:40:00 8.8 0.9 10.7 5.7 8.7 0.9 10.3 5.7 6.7 0.8 8.8 4.6 303 6 304 165 15.2 0 15.5 14.6 08/07/2006 03:50:00 8 0.9 9.9 5.3 8 0.9 9.9 5.3 6.2 0.9 9.1 4.2 301 7 311 165 15.1 0 15.5 14.9 08/07/2006 04:00:00 7.3 1 9.9 4.6 7.3 0.9 9.9 4.6 6.1 1 9.1 3.4 305 8 309 165 15 0 15.2 14.9 08/07/2006 04:10:00 5.7 1.2 8.8 3 5.8 1.2 8.8 3 5.1 1.2 8 2.3 299 11 294 165 15.1 0.1 15.5 14.9 08/07/2006 04:20:00 5.4 1.2 8.8 3 5.5 1.2 8.4 3 4.9 1 8 2.6 297 9 297 165 15.5 0 15.7 15.2 08/07/2006 04:30:00 6.8 0.8 9.1 4.2 6.9 0.8 9.1 4.9 5.9 0.9 8.4 3.8 301 8 301 165 15.3 0.1 15.7 15.2 08/07/2006 04:40:00 7.4 1 9.5 5.3 7.4 1 9.9 5.3 5.9 0.9 8.4 4.2 301 7 301 165 15.2 0 15.5 14.9 08/07/2006 04:50:00 6.9 1.2 9.9 3.8 7 1.2 9.9 4.2 5.7 1 9.9 3.4 301 9 293 165 15.2 0 15.5 14.9 08/07/2006 05:00:00 7.7 1 10.3 4.9 7.8 1 10.7 4.6 6.4 1.1 9.5 3.4 292 7 299 165 15.2 0 15.5 15.2 08/07/2006 05:10:00 8.5 0.8 11.1 6.8 8.5 0.8 11.1 6.8 7.1 1 9.9 4.6 292 6 294 165 15.1 0.1 15.2 14.9 08/07/2006 05:20:00 8.1 1 10.7 5.3 8.1 1 10.7 5.3 6.5 1 9.1 3.8 296 8 308 165 15 0 15.5 14.6 08/07/2006 05:30:00 7.6 1.5 11.5 2.6 7.6 1.5 11.5 3 6.5 1.2 9.9 3.4 307 10 301 165 15.2 0.1 15.7 14.6 08/07/2006 05:40:00 7.1 1.4 11.5 3 7.1 1.3 11.1 3.4 6 1.2 9.5 2.6 306 12 315 165 15.4 0 15.7 15.2 08/07/2006 05:50:00 6.4 1.1 10.3 3.4 6.4 1.1 10.3 3.8 5 1.2 9.1 2.3 294 9 298 165 15.1 0.1 15.5 14.6 08/07/2006 06:00:00 6.6 0.9 9.5 3.8 6.5 0.8 9.1 3.4 5.4 1 8.4 3.4 289 8 277 165 15.4 0 15.7 14.9 08/07/2006 06:10:00 5.8 1 8.4 2.3 5.7 1 8.4 1.9 4 1.4 6.8 0.7 289 10 287 165 15.6 0 16 15.5 08/07/2006 06:20:00 6.1 1 8.8 3 6.1 1 9.1 3 4.3 1.1 7.2 1.9 296 9 300 165 15.8 0 16 15.7 08/07/2006 06:30:00 4.2 1.3 8.8 0.7 4.2 1.3 8.4 1.9 2.7 1.3 7.6 0.4 289 19 300 165 16.2 0 16.6 16 08/07/2006 06:40:00 4.1 1.3 6.8 1.1 4.1 1.3 6.8 0.4 2.7 1.2 6.1 0.4 287 21 264 165 16.6 0 16.8 16.3 08/07/2006 06:50:00 4.6 2 8.4 0.4 4.7 2 8.4 0.4 3.4 1.7 7.6 0.4 291 32 297 165 16.9 0 17.1 16.6 08/07/2006 07:00:00 6.1 1.1 9.1 1.9 6.1 1.1 8.8 1.5 4.4 1.1 7.2 1.5 299 13 309 165 16.8 0 17.1 16.8 08/07/2006 07:10:00 5.2 1.5 8.8 1.9 5.3 1.5 8.8 1.1 3.7 1.3 8 0.7 303 19 305 165 17 0.2 17.4 16.8 08/07/2006 07:20:00 5.6 1.5 9.5 1.5 5.6 1.6 9.9 1.5 4.1 1.3 7.2 1.1 309 16 312 165 17.4 0 17.7 17.4 08/07/2006 07:30:00 7 1.9 12.6 1.1 7.1 1.9 12.2 1.1 5 1.8 9.9 0.7 303 18 310 165 17.3 0 17.4 17.1 08/07/2006 07:40:00 8.1 1.2 12.2 4.9 8.1 1.3 11.8 4.6 6.1 1.4 11.1 2.6 306 11 304 165 17.5 0 17.7 17.4 08/07/2006 07:50:00 7.4 1 11.5 4.2 7.4 1 11.1 4.2 5.6 1.2 8.8 1.9 302 7 311 165 17.4 0.1 17.7 17.4 08/07/2006 08:00:00 7.4 0.6 9.5 5.3 7.5 0.5 9.1 5.7 5.9 0.9 8 3.4 304 5 312 165 17.6 0 18 17.4 08/07/2006 08:10:00 6.5 0.8 9.5 3.8 6.6 0.8 9.5 4.2 4.8 1 7.2 2.3 304 6 306 165 18 0.1 18.2 17.7 08/07/2006 08:20:00 5.9 0.7 7.6 4.2 6.1 0.7 8 4.6 4.4 1 6.5 1.9 303 7 305 165 18.3 0.1 18.5 18 08/07/2006 08:30:00 5 0.8 6.5 2.6 5.3 0.8 6.8 3 3.7 0.9 6.1 1.1 306 9 302 165 18.6 0 18.8 18.2 08/07/2006 08:40:00 4.8 1.1 6.8 1.9 5 1 7.2 2.6 3.5 1.1 6.1 1.1 305 10 319 165 18.8 0 19.1 18.5 08/07/2006 08:50:00 6 0.7 8 4.2 6.1 0.7 8 4.6 5.1 1 7.6 2.6 306 8 309 165 19 0 19.1 18.8 08/07/2006 09:00:00 6.6 0.6 8 4.9 6.6 0.6 8 4.9 5.9 0.7 8 4.2 310 5 307 165 18.7 0.1 19.1 18.5 08/07/2006 09:10:00 6.7 0.7 8.4 4.9 6.6 0.7 8.4 4.9 6.1 0.8 7.6 4.2 312 6 305 165 18.2 0 18.8 18 08/07/2006 09:20:00 6.9 0.7 8.8 4.6 6.7 0.7 8.4 4.2 6.2 0.9 8.4 3.4 310 5 316 165 18.1 0 18.2 18 08/07/2006 09:30:00 7.3 0.6 9.1 5.7 7.1 0.6 8.4 5.3 6.8 0.7 8.4 4.6 314 7 313 165 18.4 0.1 18.8 18.2 08/07/2006 09:40:00 7 0.7 8.8 4.9 6.8 0.7 9.1 4.9 6.3 0.8 8.4 4.2 310 6 303 165 18.5 0 18.5 18.2 08/07/2006 09:50:00 7.9 0.6 9.5 6.1 7.8 0.6 9.5 6.1 6.8 0.7 8.8 4.9 307 4 307 165 18.5 0 18.8 18.5 08/07/2006 10:00:00 8.1 0.8 10.3 6.1 7.9 0.8 10.3 5.3 6.6 0.8 9.1 4.2 304 6 290 165 18.7 0 19.1 18.5 08/07/2006 10:10:00 7.8 0.8 9.9 4.9 7.7 0.8 9.9 4.9 6.4 0.8 8.8 4.2 303 5 292 165 18.5 0 18.8 18.2 08/07/2006 10:20:00 8.1 0.7 10.3 6.5 8 0.7 10.3 5.7 6.4 0.8 8.4 4.6 301 5 300 165 18.5 0.3 19.4 18 08/07/2006 10:30:00 7.7 1.3 10.3 4.6 7.6 1.3 10.3 4.6 6.2 1.6 9.9 2.6 296 7 293 165 19.8 0.2 20.2 19.1 08/07/2006 10:40:00 8.1 1.2 11.8 5.3 8 1.1 11.1 5.3 6.5 1.1 9.9 3.8 296 7 299 165 20.2 0 20.5 19.7 08/07/2006 10:50:00 6.7 1.2 9.9 3.8 6.6 1.2 9.9 3.8 5.6 1.3 8.8 2.6 306 10 304 165 20.2 0 20.8 19.7 08/07/2006 11:00:00 7 1.2 9.1 3 6.9 1.2 9.1 3.4 5.9 1.2 8.4 2.6 304 9 291 165 20.3 0 20.5 20.2 08/07/2006 11:10:00 7.1 0.8 9.1 5.3 7 0.8 8.8 4.9 5.8 1 8.4 3.4 297 6 306 165 20 0 20.2 19.7 08/07/2006 11:20:00 6.6 0.8 8.8 3.8 6.7 0.8 8.8 4.2 5.9 1 8.4 3.4 288 7 288 165 20.2 0 20.5 20 08/07/2006 11:30:00 6.4 0.8 8.4 4.2 6.4 0.9 8.8 4.2 5.7 1.1 9.1 3.4 289 7 287 165 20.5 0 20.8 20.2 08/07/2006 11:40:00 6.4 0.9 8.4 3.4 6.4 0.8 8.4 3.8 5.3 1 8 3 296 6 294 165 20.6 0 20.8 20.5 08/07/2006 11:50:00 6.3 0.8 8 3.4 6.2 0.8 7.6 3.4 5.1 0.8 7.2 3 299 6 300 165 20.6 0 20.8 20.5 08/07/2006 12:00:00 6.3 1 8.4 3.8 6.4 1 8.4 4.2 5.1 1 7.6 3 295 6 300 165 20.7 0.2 21.1 20.2 08/07/2006 12:10:00 6.1 1 8.4 3.4 6.3 1 8.4 3.8 5.2 1.1 8 2.3 295 6 287 165 20.6 0.1 21.1 20.5 08/07/2006 12:20:00 6.8 1.1 9.9 3.8 6.7 1.1 9.9 4.2 5.5 1 8.4 3.4 301 7 297 165 20.8 0.2 21.1 20.5 08/07/2006 12:30:00 7.4 0.9 9.5 4.9 7.2 0.9 9.9 5.3 6.7 1.1 9.1 3.8 312 7 307 165 20.9 0.1 21.1 20.2 08/07/2006 12:40:00 7.3 0.9 9.1 3.8 7.1 0.9 8.8 4.2 6.9 1 9.5 4.2 317 6 311 165 21.3 0 21.7 20.8 08/07/2006 12:50:00 6.7 1 8.8 3.8 6.6 1 8.4 4.6 6.1 1 8.4 3.8 314 8 312 165 21.8 0.1 22.3 21.4 08/07/2006 13:00:00 7 0.8 9.1 4.9 6.9 0.8 9.1 4.9 6.4 0.9 8.4 3.4 310 7 298 165 21.3 0.1 22 21.1 08/07/2006 13:10:00 6.3 1.1 8.8 3.4 6.3 1 8.4 3.8 5.4 0.9 7.6 3 306 9 302 165 21.4 0.2 22.3 21.1 08/07/2006 13:20:00 6.6 0.9 8.8 4.2 6.5 0.8 8.8 4.6 5.5 1 8 2.6 304 9 291 165 21.7 0 22.3 21.1 08/07/2006 13:30:00 7.8 0.9 9.9 5.7 7.6 0.9 9.9 5.3 6.6 1.1 9.5 4.2 308 7 309 165 21.3 0.1 22 20.8 08/07/2006 13:40:00 7.7 0.9 10.3 4.9 7.5 0.9 10.3 4.9 7 1 9.1 3.8 317 9 305 165 21.8 0.2 22.3 21.1 08/07/2006 13:50:00 8.6 0.8 10.3 6.8 8.5 0.8 10.7 6.5 7.6 1.1 10.7 4.6 312 9 300 165 21.5 0 22 21.1 08/07/2006 14:00:00 8.2 0.8 10.3 4.9 8.1 0.9 10.3 4.6 6.9 1 9.5 4.6 306 9 299 165 21.1 0.1 21.4 20.8 08/07/2006 14:10:00 8.6 0.8 10.7 5.7 8.5 0.9 10.3 5.3 7.3 1.2 9.9 3.4 307 8 297 165 21.2 0 21.1 20.8 08/07/2006 14:20:00 9 0.8 10.7 7.2 8.9 0.8 11.1 6.8 7.1 0.8 9.5 4.9 303 6 295 165 20.9 0.1 21.1 20.5 08/07/2006 14:30:00 9.2 0.7 11.1 6.5 9.2 0.8 11.1 6.5 7.3 0.9 9.5 4.6 305 5 305 165 20.9 0 21.1 20.5 08/07/2006 14:40:00 8.7 0.8 11.1 5.7 8.6 0.8 10.7 5.7 7.6 1.2 10.3 4.6 310 8 318 165 21.1 0.2 21.4 20.5 08/07/2006 14:50:00 9.6 0.8 11.5 7.6 9.5 0.8 11.5 6.8 8.7 1 11.1 5.3 312 7 302 165 21 0 21.1 20.8 08/07/2006 15:00:00 9.4 0.7 12.2 7.2 9.3 0.8 12.6 6.8 8.1 1 10.7 5.7 308 8 306 165 20.7 0.2 21.1 20.2 08/07/2006 15:10:00 9.3 1 11.8 7.2 9.3 1 11.8 6.8 8.1 1.1 10.7 5.3 308 7 313 165 20.8 0.1 21.1 20.2 08/07/2006 15:20:00 9.8 1 13.3 6.8 9.6 1 12.6 6.8 9.2 1 13.3 6.5 315 7 305 165 21 0.2 21.4 20.2 08/07/2006 15:30:00 9.9 1 12.6 6.8 9.8 1 12.6 7.2 9.2 1.1 12.2 6.5 316 8 310 165 20.8 0.1 21.1 20.5 08/07/2006 15:40:00 8.6 0.9 11.5 5.7 8.4 1 11.8 5.7 8.2 1 11.1 5.3 322 10 312 165 21.3 0.2 21.7 20.8 08/07/2006 15:50:00 9.9 1.2 13 6.8 9.8 1.3 12.6 6.5 9.2 1.1 13 6.5 316 7 313 165 21.1 0.1 21.4 20.5 08/07/2006 16:00:00 9.9 0.9 11.8 6.8 9.8 0.9 11.8 7.2 8.9 1.1 11.5 5.7 312 7 297 165 20.6 0 21.1 20.5 08/07/2006 16:10:00 10.8 1 13 8.8 10.8 1 13 8.4 9.1 1 12.2 6.5 308 5 301 165 20.4 0 20.5 20.2 08/07/2006 16:20:00 10.4 0.8 12.2 8.4 10.4 0.8 12.6 8.4 9.1 1.1 12.2 6.5 310 6 312 165 20.5 0 20.8 20.2 08/07/2006 16:30:00 10.2 1.1 13 6.8 10.1 1.2 13 6.8 8.3 0.9 11.1 5.7 305 6 295 165 20.4 0 20.8 20.2 08/07/2006 16:40:00 10.3 1.2 12.6 6.8 10.2 1.2 12.2 6.5 9.1 1.3 12.2 5.7 310 8 302 165 20.5 0 20.8 20.2 08/07/2006 16:50:00 10.3 1.2 13.3 6.8 10.2 1.2 13 6.8 9.5 1.3 13.3 5.7 314 7 301 165 20.6 0 21.1 20.5 08/07/2006 17:00:00 10.1 1 12.2 6.5 10 1 12.2 6.5 9.2 1.1 11.8 6.1 313 7 325 165 20.7 0 21.1 20.2 08/07/2006 17:10:00 9.5 1 11.8 6.5 9.4 1 11.8 6.5 8.4 1.1 11.5 5.3 312 8 309 165 20.6 0 20.8 20.2 08/07/2006 17:20:00 9.7 1 12.2 7.6 9.5 1 11.8 7.2 8.6 1 11.8 5.3 311 8 303 165 20.7 0 21.1 20.5 08/07/2006 17:30:00 9.8 1.2 12.2 4.9 9.6 1.1 11.8 4.9 8.9 1.2 12.2 4.9 312 8 312 165 20.6 0 20.8 20.2 08/07/2006 17:40:00 10.7 1.1 13 7.2 10.6 1.1 13 7.2 9.4 1.1 12.2 6.8 310 6 307 165 20.5 0 20.8 20.2 08/07/2006 17:50:00 10.8 0.8 13 8.8 10.7 0.8 13 8.8 9.6 1 11.8 5.7 311 6 311 165 20.2 0 20.5 20 08/07/2006 18:00:00 10.1 1 13 7.2 10 1 12.2 7.2 8.7 1.2 12.2 4.9 309 7 303 165 20.1 0 20.5 20 08/07/2006 18:10:00 9.6 1 13 6.8 9.5 1.1 13 7.2 8.4 1.1 11.5 5.7 310 8 307 165 20 0 20.2 20 08/07/2006 18:20:00 9.4 1.2 12.6 5.7 9.2 1.2 12.6 5.7 8.2 1.2 13 5.3 312 9 307 165 20.1 0 20.5 20 08/07/2006 18:30:00 9.8 0.9 11.8 7.6 9.7 0.9 11.8 7.6 8.5 1.1 11.5 5.7 310 7 305 165 19.9 0 20.5 19.7 08/07/2006 18:40:00 9.2 1.2 11.8 6.5 9.1 1.3 12.2 5.7 8.1 1 10.7 4.9 311 7 297 165 19.7 0 20.2 19.7 08/07/2006 18:50:00 9.3 0.9 11.5 6.5 9.2 1 11.5 6.1 8.1 0.8 11.1 5.7 310 8 304 165 19.7 0 20 19.7 08/07/2006 19:00:00 9.4 1 12.6 7.2 9.3 1 12.6 6.8 8 1.1 11.1 5.7 308 6 297 165 19.5 0 19.7 19.4 08/07/2006 19:10:00 9.8 1 12.6 7.2 9.7 0.9 11.8 6.8 7.8 1 11.1 5.3 305 6 298 165 19.4 0 19.7 19.1 08/07/2006 19:20:00 8.9 1.2 12.6 6.1 8.8 1.2 11.8 6.1 7.6 1.5 11.5 4.6 308 7 302 165 19.2 0 19.4 19.1 08/07/2006 19:30:00 9.5 1.2 12.6 6.5 9.5 1.2 12.6 6.1 7.9 1.2 11.5 5.3 307 9 307 165 19.1 0 19.4 18.8 08/07/2006 19:40:00 9.2 1.3 12.2 5.7 9 1.3 11.8 5.7 8.1 1.1 11.5 5.7 310 8 311 165 19 0 19.1 18.8 08/07/2006 19:50:00 10 0.6 11.8 8 9.9 0.7 11.8 8 9.2 0.8 11.1 6.1 313 4 305 165 18.7 0 19.1 18.5 08/07/2006 20:00:00 9.8 0.6 11.1 8 9.8 0.7 11.1 8 9.4 0.7 10.7 7.6 314 3 314 165 18.3 0 18.8 18 08/07/2006 20:10:00 9.8 0.6 11.1 8 9.6 0.6 11.1 7.6 9.3 0.6 11.1 7.6 316 4 316 165 17.9 0 18.2 17.7 08/07/2006 20:20:00 9.2 0.8 11.1 7.2 9.1 0.9 11.1 6.8 8.9 1 11.8 6.5 316 5 315 165 17.5 0.1 18 17.4 08/07/2006 20:30:00 8.8 1 11.8 6.8 8.6 1 11.8 6.5 8.1 1.1 10.7 5.7 314 4 313 165 17 0 17.4 16.8 08/07/2006 20:40:00 10.4 1 13 7.2 10.3 1 13 7.2 8.3 1.2 11.1 5.7 307 6 307 165 17.3 0 17.4 17.1 08/07/2006 20:50:00 9.2 0.8 11.1 7.2 9.1 0.8 11.1 6.8 7 1 9.9 4.9 303 6 304 165 16.8 0 17.4 16.6 08/07/2006 21:00:00 10 1.1 13.3 7.2 9.9 1.2 13.3 7.2 7.3 1.1 11.1 5.3 301 5 302 165 16.6 0 16.8 16.6 08/07/2006 21:10:00 10.7 1 13.7 8.4 10.6 1 13.3 8 8.3 1.1 11.8 5.7 306 5 304 165 16.6 0 16.8 16.6 08/07/2006 21:20:00 10.2 1.1 13.3 7.6 10 1 13 7.2 8.8 1 11.5 6.5 311 5 310 165 16.6 0 16.8 16.6 08/07/2006 21:30:00 10.1 1 12.6 7.2 9.9 1 12.2 6.8 8.3 1 11.1 5.7 307 5 305 165 16.4 0 16.6 16.3 08/07/2006 21:40:00 10.4 1 12.2 7.2 10.2 1 12.6 7.2 8.3 1 11.1 6.1 306 5 309 165 16.3 0 16.6 16.3 08/07/2006 21:50:00 10.7 0.8 13 8.4 10.5 0.8 12.6 8 8.4 1 11.1 6.5 305 5 308 165 16.2 0 16.6 16.3 08/07/2006 22:00:00 11.2 0.8 12.6 9.1 11.1 0.8 12.6 8.8 8.3 0.8 10.7 6.1 303 4 310 165 16.2 0 16.6 16.3 08/07/2006 22:10:00 11.3 0.8 13 9.1 11.1 0.8 13 9.1 9 1 11.5 5.7 307 4 298 165 16.1 0 16.3 16 08/07/2006 22:20:00 10.8 0.8 13 8.4 10.7 0.8 12.6 8.4 9.2 1 11.5 6.8 308 5 308 165 16.1 0 16.3 16 08/07/2006 22:30:00 10.8 0.7 12.6 8.8 10.7 0.7 12.2 8.4 8.9 0.9 11.1 6.1 308 4 310 165 16 0 16.3 16 08/07/2006 22:40:00 10.2 0.9 11.8 6.5 10.1 0.9 11.8 6.5 8.9 1 11.1 5.7 310 4 308 165 16.2 0 16.6 16.3 08/07/2006 22:50:00 10.1 1 12.6 7.6 10 1 12.6 7.6 9.1 1 11.1 7.2 311 5 315 165 16.4 0 16.6 16.3 08/07/2006 23:00:00 9.8 0.6 11.8 8 9.8 0.7 11.8 8 8.4 1 10.7 5.7 309 5 310 165 16.3 0.1 16.6 16.3 08/07/2006 23:10:00 10.2 0.5 11.8 8.4 10.2 0.5 11.8 8.4 7.4 0.7 9.9 5.7 303 3 302 165 16.4 0 16.6 16 08/07/2006 23:20:00 10.5 0.6 11.8 8.8 10.5 0.6 11.8 8.4 7.6 0.6 9.5 5.7 302 3 303 165 16.3 0 16.6 16.3 08/07/2006 23:30:00 11 0.5 12.2 9.9 11 0.5 11.8 9.5 7.6 0.6 9.9 6.1 301 3 303 165 16.2 0 16.6 16.3 08/07/2006 23:40:00 11.7 0.4 13 10.7 11.6 0.5 13 10.7 8.7 0.9 11.5 6.8 305 3 296 165 16.3 0 16.6 16.3 08/07/2006 23:50:00 11.5 0.6 12.6 9.1 11.4 0.6 12.6 8.8 9.7 0.8 11.5 7.6 307 4 309 165 16.3 0 16.6 16.3 08/08/2006 00:00:00 11 0.5 12.2 9.1 10.9 0.5 12.2 9.1 9.9 0.8 11.8 8 310 3 307 165 16.3 0 16.6 16.3 08/08/2006 00:10:00 10.6 0.6 12.2 9.1 10.6 0.5 11.8 9.1 8.5 1.1 11.5 5.7 307 5 297 165 16.4 0 16.6 16.3 08/08/2006 00:20:00 10.4 1 12.6 8 10.3 1 12.6 7.6 8.2 1 11.1 6.1 305 5 305 165 16.5 0 16.8 16.3 08/08/2006 00:30:00 9.4 1.1 12.2 5.7 9.2 1.1 11.8 6.1 7.5 1 10.3 4.6 305 5 298 165 16.5 0 16.8 16.3 08/08/2006 00:40:00 8.3 0.9 9.9 5.7 8.2 0.9 9.9 5.7 6.4 0.9 8.4 4.2 299 6 293 165 16.2 0 16.6 16 08/08/2006 00:50:00 8.9 0.6 10.3 7.6 8.8 0.6 10.3 7.2 6.9 0.8 9.5 5.3 297 5 292 165 16.1 0.1 16.3 16 08/08/2006 01:00:00 9 0.6 10.7 7.6 8.8 0.6 10.3 7.2 7.4 0.8 9.9 5.3 307 5 304 165 16.1 0 16.3 16 08/08/2006 01:10:00 8.9 0.7 10.7 7.2 8.8 0.8 11.1 7.2 7.2 0.8 9.5 4.9 304 5 301 165 16.2 0 16.6 16.3 08/08/2006 01:20:00 9.8 0.6 11.1 7.6 9.7 0.7 11.1 7.6 7.5 0.8 9.9 5.7 301 5 314 165 16.3 0 16.6 16.3 08/08/2006 01:30:00 10 0.7 11.5 8 9.9 0.7 11.5 8.4 7.2 0.7 9.5 5.3 298 4 293 165 16.3 0 16.6 16.3 08/08/2006 01:40:00 10 0.7 11.8 8.4 10 0.7 11.8 8 7.8 1 10.7 5.7 295 4 288 165 16.5 0 16.8 16.6 08/08/2006 01:50:00 10.1 0.7 11.8 7.2 10.1 0.7 11.5 7.2 7.6 0.9 9.9 5.3 296 4 297 165 16.6 0 16.8 16.3 08/08/2006 02:00:00 9.6 0.7 11.5 7.6 9.6 0.8 11.5 7.6 7.2 0.8 9.1 5.3 299 5 295 165 16.4 0 16.6 16.3 08/08/2006 02:10:00 9.2 0.7 11.1 7.6 9.2 0.7 11.1 7.6 6.8 0.7 8.8 5.3 297 4 300 165 16.1 0 16.6 16 08/08/2006 02:20:00 9.7 0.5 11.1 8.4 9.8 0.5 11.1 8.4 7 0.8 9.5 5.3 297 4 307 165 16.1 0 16.3 16 08/08/2006 02:30:00 9.8 0.4 10.7 8.8 9.9 0.5 11.1 8.8 7.2 0.7 9.5 5.7 299 4 292 165 16.2 0 16.3 16.3 08/08/2006 02:40:00 9.8 0.4 10.7 8.8 9.8 0.4 11.1 8 6.8 0.5 8.8 5.7 301 3 303 165 16.2 0 16.3 16 08/08/2006 02:50:00 9.5 0.4 10.3 8 9.6 0.5 10.3 7.6 6.7 0.5 8.8 5.3 299 3 297 165 16.2 0 16.6 16 08/08/2006 03:00:00 9.6 0.4 10.3 8.4 9.6 0.4 10.7 8 6.9 0.5 8.4 5.3 300 3 296 165 16.2 0 16.6 16 08/08/2006 03:10:00 9.6 0.7 11.1 6.8 9.6 0.7 11.1 6.8 7.4 0.7 9.1 5.3 303 3 302 165 16.5 0 16.8 16.3 08/08/2006 03:20:00 9 1.1 11.1 5.3 8.9 1.2 10.7 5.7 7.3 1.1 9.9 4.9 306 4 308 165 16.3 0 16.6 16.3 08/08/2006 03:30:00 7.9 0.9 9.9 4.9 7.7 0.9 9.5 5.3 6.7 0.9 8.8 4.2 310 6 306 165 15.9 0 16.3 15.2 08/08/2006 03:40:00 6.1 0.8 8 3.8 6 0.8 8 3.4 5.4 0.8 6.8 3 318 9 305 165 15.3 0.2 15.7 14.9 08/08/2006 03:50:00 7.1 0.9 8.4 4.2 7 0.9 8.4 4.2 6.3 0.9 8 3.4 311 6 307 165 15.3 0.3 16 14.9 08/08/2006 04:00:00 7.9 1.3 9.9 3 7.8 1.3 9.9 3.8 6.7 1 9.9 4.6 309 8 309 165 15.9 0.1 16.3 15.7 08/08/2006 04:10:00 8.6 1.7 11.8 4.6 8.6 1.9 11.8 4.2 6.9 0.9 9.9 4.9 308 13 296 165 16 0.3 16.6 15.5 08/08/2006 04:20:00 7.1 1.1 9.5 4.2 7 1.1 9.5 4.2 6.4 1.1 9.1 2.6 312 8 310 165 15.3 0 16 14.9 08/08/2006 04:30:00 4 1 6.8 1.5 4.2 1 6.5 1.9 2.9 0.9 4.9 0.4 302 11 316 165 15 0.1 16 14.6 08/08/2006 04:40:00 6.2 1 7.6 2.3 6.2 1 8 2.3 5.2 1.4 7.6 1.5 287 6 285 165 15.2 0.3 16 14.6 08/08/2006 04:50:00 6.9 0.5 8 5.3 6.9 0.5 8 5.7 5.4 0.7 7.6 3.4 293 4 291 165 16.1 0 16.3 15.7 08/08/2006 05:00:00 5.9 1.1 8.4 3 6 1.1 8 3.4 4.7 0.8 6.8 3 302 9 302 165 16.1 0.1 16.6 15.7 08/08/2006 05:10:00 3.4 1 6.8 1.1 3.5 1 6.8 1.5 3.3 0.8 5.7 0.7 321 17 302 165 15.4 0.2 16 14.6 08/08/2006 05:20:00 4.7 0.9 7.2 2.6 4.8 0.9 7.2 2.6 4.2 0.9 7.2 2.6 310 10 314 165 15.5 0.3 16.3 14.6 08/08/2006 05:30:00 4.7 1 7.2 2.3 4.8 1 7.2 2.6 4.3 0.9 6.1 1.9 312 14 313 165 16.2 0 16.6 16 08/08/2006 05:40:00 3.3 1.6 7.6 0.4 3.5 1.5 8.4 0.4 3.1 1.4 6.8 0.7 317 16 326 165 16 0.2 16.6 15.5 08/08/2006 05:50:00 5.6 1.4 9.5 1.9 5.6 1.3 9.5 2.3 4.8 1.2 8 1.9 307 9 311 165 15.6 0 15.7 15.2 08/08/2006 06:00:00 7.9 1 10.3 5.3 7.8 1 10.3 5.3 6.6 0.9 9.5 4.2 308 7 301 165 15.7 0 16 15.2 08/08/2006 06:10:00 8.6 0.9 10.7 6.8 8.6 1 10.7 6.5 6.7 0.7 8.8 4.9 302 6 298 165 16.1 0.1 16.3 15.7 08/08/2006 06:20:00 8.9 0.6 9.9 7.6 8.9 0.6 10.3 7.2 6.7 0.9 9.1 4.9 295 4 298 165 16.1 0 16.6 15.7 08/08/2006 06:30:00 7.2 0.7 8.8 5.7 7.1 0.7 8.8 5.7 5.5 0.8 8 3.8 295 6 293 165 15.9 0 16.3 15.7 08/08/2006 06:40:00 6.9 0.6 8.4 4.9 6.8 0.6 8.8 4.9 5.3 1 9.1 3.8 297 6 289 165 16 0 16.3 15.7 08/08/2006 06:50:00 8.2 0.5 9.1 6.8 8.3 0.6 9.5 7.2 6.4 1 8.8 4.6 294 3 289 165 16.1 0 16.3 16 08/08/2006 07:00:00 7.4 0.5 8.4 6.5 7.4 0.5 8.4 6.5 5.9 0.5 7.6 4.9 295 3 295 165 16.2 0 16.6 16.3 08/08/2006 07:10:00 7 0.4 8 5.7 7 0.5 8 5.7 5.1 0.5 6.5 3.8 296 3 290 165 16.4 0 16.8 16.3 08/08/2006 07:20:00 6.3 0.6 8 4.9 6.4 0.6 8 4.9 4.7 0.6 6.8 3.4 298 5 297 165 16.6 0 17.1 16.6 08/08/2006 07:30:00 6.2 0.7 7.6 4.6 6.3 0.7 7.6 4.6 4.6 0.6 6.5 3.4 299 5 296 165 16.5 0 16.8 16.6 08/08/2006 07:40:00 4.8 0.6 6.8 3.8 4.8 0.6 6.8 3.8 4.3 0.5 5.7 3 311 5 306 165 16.8 0.1 16.8 16.6 08/08/2006 07:50:00 4.3 1.8 7.2 0.4 4.4 1.7 7.2 0.7 3.9 1.5 6.8 0.4 305 17 311 165 16.8 0 17.1 16.8 08/08/2006 08:00:00 3.5 0.9 5.3 1.5 3.8 0.8 5.3 1.5 3.4 1 5.3 1.1 279 16 287 165 16.8 0.1 17.1 16.8 08/08/2006 08:10:00 4.4 0.7 6.1 3 4.5 0.7 6.5 3 3.9 0.6 5.3 2.6 292 6 295 165 16.8 0 16.8 16.8 08/08/2006 08:20:00 5.1 0.6 6.5 3.4 5.3 0.6 6.5 3.8 4.8 0.6 6.5 3.4 284 7 287 165 16.8 0 17.1 16.6 08/08/2006 08:30:00 5.6 0.5 7.2 4.2 5.7 0.6 7.2 4.2 4.7 0.9 7.2 3 294 5 279 165 17.2 0.2 17.4 16.8 08/08/2006 08:40:00 5.2 0.6 6.5 3.8 5.4 0.6 6.5 4.2 4.7 0.9 6.8 2.6 293 5 289 165 17.2 0 17.4 16.8 08/08/2006 08:50:00 4.7 0.6 6.1 2.3 4.9 0.5 6.1 3.4 4.7 0.6 6.1 3.4 282 7 283 165 17.5 0 17.7 17.1 08/08/2006 09:00:00 4.7 0.4 6.1 3.4 4.9 0.4 6.1 4.2 4.8 0.6 6.1 3 284 6 282 165 18 0.4 18.8 17.4 08/08/2006 09:10:00 3.7 0.6 4.9 1.5 4.1 0.5 5.3 2.6 3.9 0.6 4.9 2.3 274 6 278 165 19 0 19.4 18.5 08/08/2006 09:20:00 2.8 1 4.6 0.4 3.2 0.9 4.9 0.4 3 0.9 4.6 0.4 269 15 282 165 19.5 0 19.7 19.1 08/08/2006 09:30:00 2.1 0.5 3.4 0.4 2.9 0.5 4.2 1.5 2.7 0.6 4.2 1.1 267 13 284 165 19.6 0.1 20 19.1 08/08/2006 09:40:00 2 0.5 3.4 0.7 2.7 0.5 4.2 1.1 2.3 0.7 3.8 0.7 274 13 275 165 20.2 0 20.5 20 08/08/2006 09:50:00 0.8 0.6 2.6 0.4 1.1 0.7 3 0.4 0.8 0.6 2.3 0.4 353 69 13 165 20.1 0.5 20.8 19.4 08/08/2006 10:00:00 1.2 0.5 2.3 0.4 1.3 0.5 2.6 0.4 1 0.6 2.3 0.4 281 72 174 165 20 0.2 20.5 19.4 08/08/2006 10:10:00 2.1 0.5 3.4 0.7 2.7 0.7 4.2 0.7 2.2 0.8 3.4 0.4 268 13 246 165 20 0.1 20.8 19.7 08/08/2006 10:20:00 1.8 0.8 4.6 0.4 2.3 0.9 4.2 0.4 1.8 0.9 3.8 0.4 228 38 241 165 20.1 0 20.8 20 08/08/2006 10:30:00 3.3 1.3 5.7 0.4 3.5 1.3 6.1 0.4 3.2 1.7 6.1 0.4 229 23 199 165 19.7 0.2 20.5 19.4 08/08/2006 10:40:00 3.5 1 5.7 0.4 3.7 1 5.7 0.4 3.1 1.1 5.7 0.4 231 29 228 165 20 0 20.5 19.7 08/08/2006 10:50:00 1.8 1.1 4.6 0.4 2 1.1 4.9 0.4 1.5 1 4.2 0.4 295 98 271 165 20 0.1 20.5 19.7 08/08/2006 11:00:00 1.3 1 4.2 0.4 1.3 1 4.2 0.4 0.9 0.6 3.4 0.4 191 94 282 165 19.4 0 19.7 19.4 08/08/2006 11:10:00 1.4 0.7 3 0.4 1.4 0.7 3 0.4 1.5 0.8 3 0.4 94 36 116 165 19.5 0.2 20 18.8 08/08/2006 11:20:00 1 0.6 2.6 0.4 1 0.6 2.6 0.4 1.1 0.6 3 0.4 146 18 147 165 18.9 0 19.1 18.5 08/08/2006 11:30:00 0.9 0.6 2.6 0.4 0.9 0.6 2.6 0.4 1 0.7 2.6 0.4 131 22 139 165 19.1 0 19.4 18.5 08/08/2006 11:40:00 1 0.6 2.6 0.4 1 0.6 2.6 0.4 1 0.7 2.6 0.4 166 41 130 165 18.2 0.2 18.8 17.7 08/08/2006 11:50:00 1.3 0.9 3.4 0.4 1.3 1 3.4 0.4 0.9 0.7 3 0.4 301 79 286 165 19.5 0.4 20.2 18.5 08/08/2006 12:00:00 1.9 0.6 3.4 0.7 2 0.6 3.8 0.4 1.6 0.7 3.4 0.4 223 22 215 165 19.1 0.3 20 18.8 08/08/2006 12:10:00 1.4 0.8 3.8 0.4 1.4 0.8 3.8 0.4 1.3 0.8 4.2 0.4 209 64 296 165 19.3 0.4 20.2 18.8 08/08/2006 12:20:00 1.7 0.9 4.2 0.4 1.6 0.9 3.8 0.4 1.3 0.8 3.8 0.4 324 82 246 165 19.4 0.2 20 19.1 08/08/2006 12:30:00 1.8 0.7 3.8 0.4 1.7 0.7 3.8 0.4 1.4 0.7 3.8 0.4 94 79 25 165 19.3 0.4 20.5 18.8 08/08/2006 12:40:00 0.8 0.6 2.6 0.4 0.8 0.5 2.3 0.4 0.7 0.4 1.9 0.4 156 72 0 165 19.2 0.2 20 18.8 08/08/2006 12:50:00 1.4 0.7 3 0.4 1.3 0.7 3 0.4 1.3 0.6 3.8 0.4 122 47 31 165 18.2 0.4 19.1 17.4 08/08/2006 13:00:00 0.7 0.5 3 0.4 0.7 0.6 2.6 0.4 0.7 0.5 2.6 0.4 150 66 10 165 17.8 0 18 17.4 08/08/2006 13:10:00 0.8 0.5 2.3 0.4 0.8 0.5 2.3 0.4 1 0.6 2.3 0.4 167 18 176 165 17.7 0.2 18.2 16.8 08/08/2006 13:20:00 1.2 0.5 2.3 0.4 1 0.4 2.3 0.4 0.9 0.6 2.6 0.4 3 43 356 165 18.3 0.5 19.1 17.1 08/08/2006 13:30:00 2.1 0.4 3 1.1 1.7 0.5 2.6 0.7 2.4 0.4 3.4 1.5 9 9 15 165 19.2 0 19.4 19.1 08/08/2006 13:40:00 1.6 0.4 2.6 0.7 1.4 0.4 2.3 0.7 1.6 0.4 2.6 0.7 351 13 3 165 19.1 0 19.4 18.8 08/08/2006 13:50:00 1 0.4 1.9 0.4 0.9 0.4 1.9 0.4 0.9 0.4 1.9 0.4 335 20 351 165 19.4 0 19.7 19.1 08/08/2006 14:00:00 1.2 0.6 2.6 0.4 1.1 0.6 2.6 0.4 0.9 0.6 2.6 0.4 6 36 339 165 20.2 0.3 20.8 19.7 08/08/2006 14:10:00 1.2 0.5 2.6 0.4 1.1 0.5 2.3 0.4 1 0.5 2.3 0.4 358 22 332 165 21 0.2 21.1 20.5 08/08/2006 14:20:00 1 0.5 2.3 0.4 0.9 0.5 2.3 0.4 0.7 0.4 1.9 0.4 345 23 310 165 21.4 0.2 22.3 20.8 08/08/2006 14:30:00 1.8 0.8 3.8 0.4 1.8 0.8 3.8 0.4 1.8 0.8 3.8 0.4 160 64 143 165 21.3 0.7 22.6 20 08/08/2006 14:40:00 2.1 0.6 3.8 0.7 2.2 0.6 3.8 0.7 2.2 0.5 3.4 0.7 136 15 112 165 19.2 0.3 20 18.5 08/08/2006 14:50:00 1.9 0.6 3.4 0.7 1.9 0.6 3.8 0.4 1.9 0.7 3.8 0.4 128 21 128 165 19.5 0.4 20.2 18.5 08/08/2006 15:00:00 2 0.7 4.2 0.7 2 0.6 4.2 0.7 2.1 0.7 4.2 0.7 142 18 164 165 19.9 0 20.2 19.4 08/08/2006 15:10:00 1.8 0.6 3.4 0.4 1.8 0.6 3.4 0.4 1.9 0.6 3.8 0.4 136 16 141 165 19.5 0.1 20 19.4 08/08/2006 15:20:00 1.5 0.6 3 0.4 1.5 0.7 3.4 0.4 1.8 0.6 3 0.4 127 17 114 165 19.7 0 20.2 19.7 08/08/2006 15:30:00 2 0.9 4.6 0.4 2.1 0.9 4.6 0.4 2.1 0.8 4.2 0.4 148 17 153 165 19.7 0.2 20.2 19.4 08/08/2006 15:40:00 2 0.7 3.8 0.4 2 0.7 4.2 0.7 2 0.7 4.2 0.4 145 15 135 165 19.8 0 20 19.7 08/08/2006 15:50:00 1.8 0.5 3.4 0.4 1.8 0.5 3 0.4 1.8 0.5 3.4 0.4 140 21 150 165 19.9 0.2 20.2 19.4 08/08/2006 16:00:00 1.9 0.4 3 1.1 1.9 0.4 3 1.1 2 0.4 3 0.7 136 11 147 165 18.7 0.4 19.7 18.2 08/08/2006 16:10:00 0.5 0.3 1.5 0.4 0.5 0.3 1.5 0.4 0.6 0.3 1.5 0.4 114 13 130 165 18.9 0.3 19.4 18.2 08/08/2006 16:20:00 1 0.5 2.6 0.4 1.1 0.5 2.6 0.4 1 0.6 2.6 0.4 138 16 127 165 19.6 0.2 20 18.8 08/08/2006 16:30:00 0.7 0.4 1.9 0.4 0.7 0.5 1.9 0.4 0.8 0.5 2.3 0.4 146 12 141 165 18.9 0 19.1 18.5 08/08/2006 16:40:00 0.6 0.3 1.9 0.4 0.6 0.4 1.9 0.4 0.6 0.4 1.9 0.4 114 35 111 165 18.8 0 19.1 18.5 08/08/2006 16:50:00 0.7 0.5 2.3 0.4 0.7 0.5 2.3 0.4 0.7 0.4 2.3 0.4 167 82 327 165 18.8 0 19.4 18.5 08/08/2006 17:00:00 0.9 0.5 1.9 0.4 1 0.5 2.3 0.4 0.8 0.5 2.3 0.4 300 14 293 165 19.5 0 19.7 19.1 08/08/2006 17:10:00 0.4 0.2 1.1 0.4 0.4 0.2 1.5 0.4 0.4 0.1 1.1 0.4 304 5 310 165 19.1 0 19.4 18.8 08/08/2006 17:20:00 0.7 0.4 1.5 0.4 0.7 0.4 1.5 0.4 0.6 0.3 1.5 0.4 294 28 301 165 18.8 0.2 19.1 18 08/08/2006 17:30:00 0.9 0.4 1.9 0.4 0.9 0.4 1.9 0.4 0.7 0.4 1.9 0.4 282 32 305 165 17.5 0 18 17.4 08/08/2006 17:40:00 1.3 0.5 2.3 0.4 1.1 0.4 1.9 0.4 1.1 0.5 1.9 0.4 340 9 359 165 18 0.1 18.2 17.7 08/08/2006 17:50:00 0.4 0 0.7 0.4 0.4 0 0.7 0.4 0.4 0 0.4 0.4 280 72 191 165 18.1 0.1 18.2 18 08/08/2006 18:00:00 0.4 0.1 0.7 0.4 0.4 0.2 1.1 0.4 0.4 0.1 1.1 0.4 239 32 191 165 17.9 0 18.2 17.7 08/08/2006 18:10:00 0.7 0.4 1.5 0.4 0.8 0.4 1.5 0.4 0.5 0.2 1.1 0.4 265 7 271 165 17.5 0.1 17.7 17.1 08/08/2006 18:20:00 1.3 0.3 1.9 0.7 1.4 0.3 2.3 0.7 0.9 0.3 1.9 0.4 286 5 285 165 17 0.1 17.7 16.8 08/08/2006 18:30:00 2.6 0.2 3 1.9 2.7 0.2 3 2.3 1.9 0.4 3 1.1 285 5 292 165 17 0 17.1 16.8 08/08/2006 18:40:00 2.8 0.5 3.8 1.9 2.9 0.5 4.2 1.9 2 0.5 3.4 0.7 291 8 290 165 17.1 0 17.4 16.8 08/08/2006 18:50:00 3.1 0.3 4.2 1.9 3.2 0.3 4.2 2.6 2.3 0.5 5.3 1.5 293 10 291 165 16.9 0.1 17.1 16.8 08/08/2006 19:00:00 2.5 0.3 3 1.9 2.7 0.3 3.4 2.3 1.7 0.4 2.6 0.7 291 3 289 165 16.7 0 16.8 16.6 08/08/2006 19:10:00 2 0.4 2.6 0.7 2.3 0.4 3 1.1 1.6 0.3 2.3 0.7 290 8 289 165 16.8 0 16.8 16.6 08/08/2006 19:20:00 1.1 0.3 1.9 0.4 1.4 0.3 2.3 0.7 1.2 0.3 1.9 0.4 282 14 269 165 16.9 0 17.1 16.8 08/08/2006 19:30:00 1.3 0.2 1.9 0.7 1.6 0.2 2.3 0.7 1.5 0.2 1.9 0.7 305 8 311 165 16.6 0.1 17.1 16.3 08/08/2006 19:40:00 1.5 0.2 1.9 0.7 1.7 0.2 2.3 1.1 1.8 0.2 2.3 1.1 324 5 328 165 16.1 0 16.6 16 08/08/2006 19:50:00 1.1 0.3 1.9 0.7 1.5 0.2 2.3 1.1 1.4 0.3 1.9 0.7 297 8 287 165 16.1 0 16.3 16 08/08/2006 20:00:00 1.2 0.3 1.9 0.7 1.6 0.3 2.3 1.1 1.5 0.3 2.3 0.7 293 1 292 165 16.3 0 16.6 16.3 08/08/2006 20:10:00 0.7 0.3 1.5 0.4 1 0.3 2.3 0.4 1.1 0.2 1.9 0.7 294 0 294 165 16.6 0 16.8 16.6 08/08/2006 20:20:00 1.8 0.4 2.6 1.1 2.1 0.3 3 1.5 1.4 0.4 2.3 0.4 293 5 295 165 16.4 0.1 16.8 16.3 08/08/2006 20:30:00 2.1 0.4 3.4 1.1 2.4 0.4 3.4 1.5 1.7 0.5 3 0.7 290 9 289 165 16.2 0 16.6 16.3 08/08/2006 20:40:00 3.6 1.2 5.3 1.5 3.9 1.1 5.7 1.9 3.6 1.2 5.3 1.5 279 7 282 165 16.1 0 16.6 16 08/08/2006 20:50:00 3.9 0.6 5.3 2.6 4.1 0.6 5.3 2.6 3.3 0.7 5.3 1.9 297 7 288 165 16 0 16.3 16 08/08/2006 21:00:00 2.7 0.7 4.2 1.5 3 0.6 4.2 1.9 2.5 0.5 4.2 1.1 283 9 284 165 16.2 0.1 16.6 16 08/08/2006 21:10:00 2.2 0.4 3 1.1 2.6 0.4 3.8 1.9 2.5 0.4 3.4 1.5 273 6 277 165 16.6 0 16.8 16.6 08/08/2006 21:20:00 1.4 0.5 2.3 0.4 1.8 0.5 2.6 0.4 1.7 0.6 2.6 0.4 276 10 273 165 16.7 0 16.8 16.6 08/08/2006 21:30:00 2.9 0.9 4.6 1.1 3.5 0.8 4.6 1.5 3.1 0.7 4.6 1.1 261 15 249 165 16.6 0 16.8 16.6 08/08/2006 21:40:00 3.8 0.6 4.9 1.9 4.2 0.4 5.3 3.4 4 0.4 4.6 3 253 14 239 165 16.3 0.1 16.8 16.3 08/08/2006 21:50:00 3.8 0.6 5.3 2.3 4.5 0.4 5.3 3 4.3 0.3 5.3 2.6 260 12 250 165 16.8 0 16.8 16.8 08/08/2006 22:00:00 3 0.6 4.6 1.9 3.2 0.6 4.6 1.9 3.3 0.6 4.6 2.3 225 10 235 165 16.8 0 17.1 16.8 08/08/2006 22:10:00 1.8 0.4 2.6 0.7 1.9 0.4 3 0.7 2 0.4 3 0.7 220 10 222 165 16.7 0 16.8 16.8 08/08/2006 22:20:00 2.5 0.6 3.4 0.7 2.5 0.5 3.4 1.1 2.7 0.6 3.8 1.1 176 10 180 165 16.8 0 17.1 16.6 08/08/2006 22:30:00 2.6 0.3 3.4 1.9 2.6 0.3 3.4 1.9 2.8 0.3 3.8 1.9 167 11 163 165 16.3 0.1 16.8 16.3 08/08/2006 22:40:00 2.5 0.5 3.4 0.7 2.5 0.5 3.4 0.7 2.7 0.5 3.4 1.1 173 5 165 165 16.6 0 16.8 16.6 08/08/2006 22:50:00 0.7 0.4 1.5 0.4 0.7 0.5 1.5 0.4 0.9 0.5 1.9 0.4 158 5 165 165 16.6 0 16.8 16.6 08/08/2006 23:00:00 1.2 0.5 2.3 0.4 1.6 0.5 2.6 0.4 1.3 0.6 2.3 0.4 278 53 278 165 17 0.3 17.7 16.8 08/08/2006 23:10:00 0.9 0.4 1.9 0.4 1.1 0.5 2.3 0.4 1.1 0.4 1.9 0.4 220 45 273 165 17.5 0.1 17.7 17.1 08/08/2006 23:20:00 0.7 0.3 1.5 0.4 0.7 0.3 1.5 0.4 1 0.3 1.5 0.4 185 22 188 165 17 0 17.4 16.8 08/08/2006 23:30:00 1.5 0.3 2.3 0.4 1.5 0.3 2.3 0.4 1.7 0.3 2.3 1.1 166 8 173 165 16.6 0.3 17.1 16.3 08/08/2006 23:40:00 1.7 0.3 2.3 1.1 1.6 0.3 2.3 1.1 1.7 0.3 2.3 1.1 170 5 177 165 16.6 0 16.8 16.6 08/08/2006 23:50:00 2 0.4 2.6 0.7 1.9 0.4 2.6 0.7 2 0.3 2.6 1.1 175 5 179 165 16.6 0 16.8 16.6 08/09/2006 00:00:00 1.6 0.5 2.3 0.4 1.5 0.6 2.3 0.4 1.8 0.6 2.6 0.4 170 5 169 165 16.7 0 16.8 16.6 08/09/2006 00:10:00 1.6 0.5 2.3 0.4 1.6 0.5 2.3 0.4 2 0.4 2.6 0.7 176 1 176 165 16.4 0.1 16.8 16.3 08/09/2006 00:20:00 1.2 0.9 4.2 0.4 1.1 1 4.2 0.4 0.8 0.5 2.6 0.4 210 24 242 165 16.4 0 16.8 16.3 08/09/2006 00:30:00 1.8 0.5 2.6 0.4 2 0.6 3 0.4 1.6 0.6 2.6 0.4 242 11 252 165 17.3 0.3 17.7 16.8 08/09/2006 00:40:00 1.3 0.5 2.3 0.4 1.6 0.5 2.3 0.4 1.2 0.5 2.3 0.4 241 11 234 165 17.5 0 17.7 17.4 08/09/2006 00:50:00 1.8 0.6 3 0.4 2.2 0.4 3 0.7 1.9 0.4 2.6 0.7 275 10 286 165 17.7 0.1 18 17.4 08/09/2006 01:00:00 0.7 0.4 1.9 0.4 0.9 0.5 2.3 0.4 0.6 0.4 1.9 0.4 265 17 272 165 17.2 0.3 18 16.8 08/09/2006 01:10:00 0.6 0.3 1.9 0.4 0.6 0.4 1.9 0.4 0.5 0.2 1.1 0.4 221 36 247 165 16.6 0 16.8 16.3 08/09/2006 01:20:00 0.5 0.3 1.9 0.4 0.5 0.3 1.9 0.4 0.6 0.3 1.5 0.4 223 32 250 165 16.2 0 16.6 16.3 08/09/2006 01:30:00 0.5 0.2 1.1 0.4 0.4 0.1 1.1 0.4 0.6 0.4 1.5 0.4 194 22 174 165 16 0 16.3 16 08/09/2006 01:40:00 0.6 0.3 1.5 0.4 0.6 0.3 1.5 0.4 0.7 0.4 1.5 0.4 183 11 174 165 16.3 0.1 16.6 16 08/09/2006 01:50:00 0.6 0.4 1.9 0.4 0.6 0.4 1.5 0.4 0.5 0.3 1.5 0.4 173 1 176 165 16.4 0.1 16.8 16.3 08/09/2006 02:00:00 0.8 0.4 1.9 0.4 0.9 0.5 1.9 0.4 0.5 0.3 1.5 0.4 192 19 196 165 16.2 0 16.3 16.3 08/09/2006 02:10:00 0.5 0.2 1.5 0.4 0.6 0.4 1.5 0.4 0.6 0.3 1.5 0.4 274 13 249 165 16 0 16.3 16 08/09/2006 02:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 281 1 165 165 16 0 16.3 16 08/09/2006 02:30:00 1.4 1 3 0.4 1.4 1 3 0.4 1.6 0.9 3 0.4 174 39 158 165 15.9 0 16.3 15.7 08/09/2006 02:40:00 1.7 0.7 2.6 0.7 1.6 0.7 2.6 0.4 1.9 0.4 2.6 1.1 145 8 158 165 15.5 0 15.7 15.5 08/09/2006 02:50:00 0.6 0.2 1.1 0.4 0.4 0.2 1.1 0.4 0.9 0.3 1.5 0.4 138 2 139 165 15.6 0 15.7 15.5 08/09/2006 03:00:00 0.4 0.2 1.1 0.4 0.4 0.1 0.7 0.4 0.7 0.4 1.5 0.4 37 69 354 165 15.7 0 15.7 15.7 08/09/2006 03:10:00 1.6 0.5 2.6 0.4 1.7 0.5 3 0.4 1.3 0.4 2.3 0.7 302 19 298 165 15.7 0 16.3 15.7 08/09/2006 03:20:00 0.8 0.4 1.9 0.4 0.8 0.4 1.5 0.4 0.9 0.4 1.9 0.4 302 1 302 165 16.3 0 16.8 16 08/09/2006 03:30:00 1.5 0.5 2.3 0.4 1.6 0.5 2.3 0.4 1.7 0.5 2.3 0.4 310 7 305 165 16.6 0 16.8 16.3 08/09/2006 03:40:00 1.2 0.4 2.3 0.4 1.3 0.5 2.3 0.4 1.6 0.4 2.3 0.4 306 10 300 165 16.4 0.1 16.8 16.3 08/09/2006 03:50:00 0.7 0.4 1.5 0.4 0.7 0.4 1.9 0.4 1 0.7 2.3 0.4 321 4 329 165 16.4 0 16.6 16.3 08/09/2006 04:00:00 0.9 0.3 1.5 0.4 0.9 0.3 1.5 0.4 1.4 0.2 1.9 0.7 327 6 330 165 16.4 0 16.6 16.3 08/09/2006 04:10:00 1 0.6 2.3 0.4 1.1 0.6 2.3 0.4 1.5 0.6 2.3 0.4 183 82 135 165 16.1 0.2 16.8 15.7 08/09/2006 04:20:00 0.9 0.6 2.3 0.4 1 0.6 2.3 0.4 1.5 0.5 2.3 0.4 118 2 121 165 15.7 0 16.3 15.7 08/09/2006 04:30:00 0.4 0.2 1.5 0.4 0.4 0.1 1.1 0.4 0.8 0.4 1.9 0.4 66 38 6 165 16.1 0.2 16.6 15.7 08/09/2006 04:40:00 1.9 0.4 2.6 0.7 1.6 0.5 2.6 0.4 2.3 0.4 3 1.1 30 39 1 165 15.9 0.2 16.6 15.7 08/09/2006 04:50:00 1.8 0.6 2.6 0.4 1.9 0.6 2.6 0.4 2 0.3 2.6 1.5 102 10 115 165 15.7 0 16 15.7 08/09/2006 05:00:00 0.7 0.4 1.9 0.4 0.7 0.5 1.9 0.4 1.1 0.3 1.9 0.4 46 35 85 165 15.9 0 16.3 15.7 08/09/2006 05:10:00 0.5 0.3 1.1 0.4 0.6 0.3 1.5 0.4 0.8 0.3 1.5 0.4 63 14 75 165 16.1 0 16.3 16 08/09/2006 05:20:00 0.8 0.4 1.5 0.4 0.7 0.4 1.5 0.4 1.2 0.2 1.5 0.7 100 21 82 165 16.1 0 16.8 16 08/09/2006 05:30:00 1.1 0.3 1.5 0.4 0.9 0.4 1.5 0.4 1.3 0.4 1.9 0.7 150 15 129 165 15.6 0 16 15.5 08/09/2006 05:40:00 0.4 0.3 1.5 0.4 0.4 0.2 1.5 0.4 1 0.3 1.9 0.7 163 1 164 165 15.5 0 15.7 15.2 08/09/2006 05:50:00 1 0.3 1.5 0.4 0.8 0.4 1.5 0.4 1.5 0.3 1.9 0.7 164 12 164 165 15.3 0.1 15.5 15.2 08/09/2006 06:00:00 0.7 0.2 1.1 0.4 0.4 0 0.4 0.4 1.2 0.2 1.5 0.7 165 0 165 165 15.2 0 15.5 14.9 08/09/2006 06:10:00 0.6 0.3 1.1 0.4 0.4 0.2 1.1 0.4 1.2 0.3 1.9 0.7 166 2 165 165 15.2 0 15.5 15.2 08/09/2006 06:20:00 0.9 0.3 1.5 0.4 0.4 0 0.4 0.4 1.3 0.2 1.9 0.7 172 6 181 165 15.2 0 15.5 14.9 08/09/2006 06:30:00 1.1 0.2 1.5 0.7 0.4 0 0.4 0.4 1.3 0.2 1.9 0.7 180 1 181 165 15 0 15.2 14.6 08/09/2006 06:40:00 0.6 0.3 1.1 0.4 0.4 0 0.4 0.4 1 0.2 1.5 0.7 180 1 181 165 14.8 0 15.2 14.9 08/09/2006 06:50:00 0.4 0.3 1.5 0.4 0.4 0 0.4 0.4 1.4 0.2 1.9 0.7 177 3 174 165 14.8 0 14.9 14.6 08/09/2006 07:00:00 1.9 0.2 2.3 1.1 1.8 0.4 2.3 0.4 2 0.2 2.3 1.5 176 3 173 165 14.6 0 14.9 14.4 08/09/2006 07:10:00 0.9 0.7 2.3 0.4 0.9 0.6 2.3 0.4 1.1 0.7 2.3 0.4 191 20 180 165 14.8 0.2 15.5 14.4 08/09/2006 07:20:00 0.5 0.2 1.5 0.4 0.5 0.2 1.5 0.4 1 0.4 1.5 0.4 296 15 298 165 15 0 15.5 14.9 08/09/2006 07:30:00 0.5 0.2 1.1 0.4 0.4 0.1 1.1 0.4 0.9 0.4 1.5 0.4 302 8 296 165 15 0.1 15.7 14.9 08/09/2006 07:40:00 1.1 0.6 1.9 0.4 0.7 0.3 1.5 0.4 1.6 0.5 2.6 0.7 339 16 353 165 16 0.1 16.3 15.7 08/09/2006 07:50:00 2.2 0.4 3 1.5 1.4 0.4 2.6 0.7 2.6 0.4 3.4 1.9 1 5 354 165 15.4 0.2 16 14.9 08/09/2006 08:00:00 2.6 0.3 3.4 1.9 1.7 0.4 3 0.7 2.8 0.4 3.8 1.5 6 6 7 165 14.6 0 15.2 14.4 08/09/2006 08:10:00 1.9 0.2 2.6 1.1 1.6 0.4 2.3 0.7 2 0.3 2.6 1.1 17 6 16 165 14.3 0 14.6 14.1 08/09/2006 08:20:00 2.1 0.5 3 1.1 1.5 0.6 3 0.4 2.2 0.5 3.4 1.1 358 10 352 165 14.2 0 14.6 14.1 08/09/2006 08:30:00 2.7 0.3 3.4 1.9 2 0.8 3.4 0.4 3 0.3 3.4 2.3 351 6 343 165 14.1 0 14.4 14.1 08/09/2006 08:40:00 1.7 0.3 2.3 1.1 1.4 0.4 2.3 0.4 2 0.3 2.6 1.5 14 7 358 165 14.2 0 14.6 14.1 08/09/2006 08:50:00 1 0.5 1.9 0.4 0.7 0.4 1.5 0.4 1.2 0.5 2.3 0.4 17 15 15 165 14.9 0.2 15.2 14.6 08/09/2006 09:00:00 0.5 0.4 2.3 0.4 0.5 0.4 1.9 0.4 0.8 0.5 2.3 0.4 106 49 142 165 16.5 0.9 18.2 15.2 08/09/2006 09:10:00 0.8 0.6 2.3 0.4 0.8 0.6 2.6 0.4 0.9 0.7 2.6 0.4 207 47 241 165 18.2 0 18.8 18 08/09/2006 09:20:00 0.9 0.6 2.6 0.4 0.8 0.6 2.6 0.4 1.1 0.6 2.3 0.4 179 20 170 165 17 0.5 18 16.3 08/09/2006 09:30:00 1.4 0.7 2.6 0.4 1.3 0.7 2.6 0.4 1.7 0.7 3 0.4 173 17 165 165 16.4 0 16.8 16.3 08/09/2006 09:40:00 1.3 0.3 2.3 0.4 1.1 0.4 2.3 0.4 1.7 0.3 2.6 0.7 170 8 170 165 15.9 0.4 16.8 15.2 08/09/2006 09:50:00 1 0.4 1.9 0.4 0.9 0.5 2.3 0.4 1.5 0.4 2.3 0.4 167 13 155 165 15.5 0 15.7 15.2 08/09/2006 10:00:00 0.5 0.4 2.3 0.4 0.5 0.5 2.6 0.4 0.8 0.4 1.9 0.4 169 33 205 165 15.6 0.2 16.8 15.2 08/09/2006 10:10:00 1 0.7 3 0.4 1.1 0.8 3 0.4 1.2 0.7 3.4 0.4 209 47 165 165 16.5 0.1 16.8 16.3 08/09/2006 10:20:00 0.8 0.5 2.3 0.4 1 0.6 2.3 0.4 1.1 0.5 2.6 0.4 287 24 297 165 16.8 0 17.1 16.8 08/09/2006 10:30:00 1 0.5 2.3 0.4 1.3 0.5 2.3 0.4 1.2 0.5 2.3 0.4 288 13 308 165 16.6 0 16.8 16.6 08/09/2006 10:40:00 0.9 0.6 2.6 0.4 1.3 0.8 3 0.4 1.2 0.7 3 0.4 289 22 274 165 16.8 0 17.1 16.6 08/09/2006 10:50:00 0.6 0.5 2.3 0.4 0.9 0.5 2.6 0.4 1 0.6 2.3 0.4 287 23 336 165 16.6 0 17.1 16.6 08/09/2006 11:00:00 1.3 0.8 3.8 0.4 1.7 0.9 4.2 0.4 1.6 0.8 4.2 0.4 253 36 272 165 16.6 0 17.1 16.3 08/09/2006 11:10:00 2.1 0.8 3.4 0.4 2 0.6 3.4 0.4 2.1 0.7 3.8 0.4 346 36 15 165 17.3 0.4 18 16.8 08/09/2006 11:20:00 2.7 0.5 3.8 1.5 2.5 0.6 3.8 1.1 2.8 0.5 3.8 1.1 20 13 10 165 18.1 0 18.5 17.7 08/09/2006 11:30:00 3.5 0.6 5.7 2.3 3.5 0.6 5.7 1.5 3.6 0.5 5.3 2.3 28 10 33 165 17.8 0 18.2 17.7 08/09/2006 11:40:00 4.1 0.5 6.1 2.6 4.1 0.5 5.7 2.6 4.1 0.6 5.3 2.6 39 9 52 165 17.5 0.1 17.7 17.4 08/09/2006 11:50:00 5.2 0.8 6.8 3 5.2 0.8 6.8 3 5.2 1 7.2 2.6 34 7 27 165 17.7 0.2 18.2 16.8 08/09/2006 12:00:00 7.3 0.6 8.8 5.3 7.3 0.7 8.8 5.3 7.5 0.8 9.1 5.7 37 5 36 165 16.1 0.5 17.1 15.5 08/09/2006 12:10:00 8.7 0.5 9.9 7.2 8.7 0.6 10.3 6.5 8.7 0.7 9.9 5.7 34 4 39 165 15.2 0.3 16 14.6 08/09/2006 12:20:00 9 0.6 10.3 6.8 9 0.8 10.3 5.7 8.9 0.8 10.7 6.5 31 5 34 165 14.2 0.1 14.9 14.1 08/09/2006 12:30:00 9.5 0.9 11.8 6.1 9.4 1 11.5 5.3 9.3 1 12.6 6.5 27 5 31 165 14 0 14.4 13.8 08/09/2006 12:40:00 10.1 0.8 12.6 8 9.8 1.1 12.2 5.7 10.1 1 12.6 7.2 24 5 26 165 13.9 0 14.4 13.8 08/09/2006 12:50:00 9.6 1 12.2 6.5 9.3 1.2 12.2 5.7 9.4 1 11.8 7.2 23 6 29 165 14.1 0 14.4 13.8 08/09/2006 13:00:00 9.8 0.8 11.5 6.8 9.6 1 11.5 6.1 9.7 0.9 11.5 7.2 25 4 28 165 13.8 0 14.1 13.5 08/09/2006 13:10:00 10.1 0.7 11.8 7.6 9.9 1 11.8 6.5 10 0.9 12.2 7.6 24 5 28 165 13.7 0.1 14.1 13.5 08/09/2006 13:20:00 10.5 0.6 11.8 7.6 10.2 0.7 11.8 6.8 10.5 0.8 12.2 8 22 4 22 165 14 0 14.4 13.8 08/09/2006 13:30:00 10.4 0.6 12.6 8.4 10 0.9 11.8 6.8 10.5 0.8 12.2 8.4 20 3 15 165 14 0 14.4 13.8 08/09/2006 13:40:00 9.9 0.6 12.2 7.6 9.4 1 11.8 4.6 10 0.8 12.6 7.6 20 4 21 165 13.7 0 14.1 13.5 08/09/2006 13:50:00 8.4 0.8 10.3 5.3 7.9 1 10.3 4.6 8.1 1 10.3 5.7 21 7 23 165 13.9 0.1 14.6 13.5 08/09/2006 14:00:00 7.5 0.6 8.8 4.9 7.1 0.9 8.4 3.4 7.5 0.8 9.1 5.3 21 6 19 165 14.6 0 14.9 14.4 08/09/2006 14:10:00 6.8 0.7 8.8 4.9 6.5 0.8 8.4 3.8 6.6 0.8 8.4 4.6 23 6 23 165 14.8 0.2 15.2 14.6 08/09/2006 14:20:00 5.9 0.7 7.6 3.8 5.8 0.8 7.6 4.2 5.8 0.9 7.6 3.8 25 7 14 165 15.2 0 15.5 14.9 08/09/2006 14:30:00 5.5 0.7 7.2 3.4 5.5 0.8 7.2 2.3 5.9 0.8 8.4 3.8 26 8 35 165 15 0 15.5 14.9 08/09/2006 14:40:00 5.4 0.6 6.8 3.8 5.4 0.7 6.8 3 5.6 0.6 7.2 3.8 23 7 12 165 15.2 0 15.7 15.2 08/09/2006 14:50:00 4.7 0.6 6.5 3.4 4.7 0.7 6.1 2.6 4.9 0.6 6.5 3 24 8 20 165 15.2 0 15.5 15.2 08/09/2006 15:00:00 4.5 0.5 5.7 3 3.8 0.8 5.3 1.9 4.7 0.5 6.1 3.4 8 10 13 165 15.2 0 15.5 15.2 08/09/2006 15:10:00 4.7 0.5 5.7 3 3.6 0.9 5.7 1.9 4.9 0.5 6.1 3.8 7 8 12 165 15.5 0 15.7 15.5 08/09/2006 15:20:00 4.5 0.6 6.1 3 3.6 0.8 5.7 1.9 4.9 0.6 6.5 3.8 4 10 11 165 14.9 0.2 15.7 14.6 08/09/2006 15:30:00 3.8 0.7 5.7 1.9 3.2 0.8 5.3 1.9 4.2 0.6 6.1 2.6 357 9 4 165 14.8 0.2 15.2 14.4 08/09/2006 15:40:00 2.3 0.9 4.2 0.4 2.7 0.8 4.2 1.1 2.8 0.8 4.2 1.1 322 15 313 165 14.9 0.3 15.5 14.4 08/09/2006 15:50:00 1.8 0.6 3.8 0.4 2.3 0.5 3.8 1.1 1.7 0.5 2.6 0.4 303 26 282 165 13.9 0 14.6 13.8 08/09/2006 16:00:00 1.9 0.8 4.2 0.4 2.8 0.7 4.6 1.1 2.2 0.7 3.8 0.7 265 16 247 165 14.2 0.2 14.6 13.8 08/09/2006 16:10:00 1.5 0.8 3.4 0.4 2 0.8 4.2 0.4 2 0.7 3.4 0.4 196 41 230 165 14.8 0 15.2 14.4 08/09/2006 16:20:00 1.3 0.6 2.6 0.4 1.7 0.6 3 0.4 1.8 0.5 3 0.4 190 21 224 165 13.9 0 14.6 13.5 08/09/2006 16:30:00 0.7 0.8 5.7 0.4 1.1 0.9 5.7 0.4 0.9 0.8 5.3 0.4 222 56 304 165 13.7 0 13.8 13.5 08/09/2006 16:40:00 5.1 1.1 7.6 2.3 5.1 1.1 7.6 2.6 4 1 6.8 1.1 298 9 296 165 14.1 0.2 14.4 13.5 08/09/2006 16:50:00 6.7 0.7 8.8 4.6 6.6 0.7 8.4 4.6 5.3 0.7 7.6 3 297 5 300 165 14.3 0 14.6 14.4 08/09/2006 17:00:00 8.1 0.7 9.5 6.1 8 0.8 9.5 5.7 6.3 0.9 8.4 4.2 303 5 311 165 14.1 0 14.4 13.8 08/09/2006 17:10:00 8.6 0.9 11.1 5.3 8.5 1 11.1 5.3 7.1 1 9.1 4.2 305 6 302 165 14 0 14.1 13.8 08/09/2006 17:20:00 8.2 0.7 9.9 6.1 8.1 0.8 9.9 5.7 6.2 0.9 9.5 3.8 298 5 296 165 14.1 0 14.4 14.1 08/09/2006 17:30:00 7.5 0.8 9.5 5.3 7.4 0.8 9.5 4.9 6.1 0.7 8.4 4.6 305 6 301 165 14.1 0 14.4 14.1 08/09/2006 17:40:00 6.6 0.9 9.1 4.2 6.4 0.8 9.1 4.2 5.2 0.8 8.4 3 301 6 296 165 14.6 0.1 14.9 14.4 08/09/2006 17:50:00 5.4 1.1 8 1.9 5.4 1 8 2.3 4.1 1.2 6.8 0.4 296 11 293 165 14.8 0 15.2 14.6 08/09/2006 18:00:00 4.6 1.1 6.8 1.1 4.8 1 6.8 1.5 3.5 1.1 6.8 1.1 298 12 301 165 14.7 0 14.9 14.6 08/09/2006 18:10:00 2.6 1.2 5.7 0.4 2.7 1.2 5.7 0.4 2.5 1.1 5.7 0.4 326 22 312 165 14.7 0 14.9 14.6 08/09/2006 18:20:00 1 0.9 4.6 0.4 1.1 1 4.6 0.4 1.1 1 4.6 0.4 357 47 327 165 14.6 0 15.2 14.6 08/09/2006 18:30:00 5.1 2.4 8.8 0.4 5 2.3 8.8 0.4 4.8 2 8.4 0.4 321 32 308 165 14.4 0 14.6 14.1 08/09/2006 18:40:00 4.9 1.5 8 1.5 5 1.3 8 2.3 4.2 1.7 8.4 0.4 316 15 308 165 14.2 0 14.4 14.1 08/09/2006 18:50:00 5 1 7.6 2.3 5.1 0.9 7.6 2.6 4.1 1 6.5 0.7 316 15 344 165 14 0 14.6 13.8 08/09/2006 19:00:00 3.6 1.3 6.5 1.5 3.7 1.3 6.8 1.1 3.2 1.3 6.8 0.4 324 17 308 165 14 0 14.1 13.8 08/09/2006 19:10:00 4.8 1 7.2 2.6 4.9 1 7.2 2.6 4.2 1.1 7.2 1.1 312 9 310 165 13.9 0 14.4 13.8 08/09/2006 19:20:00 4.5 1 6.8 1.9 4.5 1 6.8 2.3 3.8 0.8 6.1 1.9 314 16 287 165 13.8 0 13.8 13.5 08/09/2006 19:30:00 5.3 1 8 2.6 5.4 1 7.6 2.6 3.6 1 6.5 0.7 303 11 307 165 13.7 0 13.8 13.5 08/09/2006 19:40:00 4.9 1.2 7.6 1.1 5 1.2 7.6 1.1 3.4 1 5.7 0.7 298 17 305 165 13.5 0 13.8 13.5 08/09/2006 19:50:00 4.2 1.3 6.8 1.1 4.3 1.3 6.8 1.5 3.1 1.2 5.7 0.4 296 17 294 165 13.5 0 13.5 13.3 08/09/2006 20:00:00 2.9 1 6.1 0.7 3 1 6.5 0.7 2.7 0.7 4.6 0.7 321 12 313 165 13.4 0 13.5 13.3 08/09/2006 20:10:00 1.5 0.8 3.4 0.4 1.5 0.9 3.8 0.4 1.8 0.8 4.2 0.4 314 49 304 165 13.4 0 13.5 13 08/09/2006 20:20:00 1.1 1 4.6 0.4 1.1 1 4.2 0.4 1.2 1.1 4.2 0.4 305 56 355 165 13.2 0 13.5 12.7 08/09/2006 20:30:00 2.1 0.8 4.2 0.4 2.2 0.8 4.6 0.4 2.1 0.8 4.6 0.7 308 18 324 165 13.3 0 13.5 12.7 08/09/2006 20:40:00 1.8 1.5 5.7 0.4 1.8 1.5 5.7 0.4 1.4 1.2 4.9 0.4 360 86 296 165 13.3 0 13.3 12.7 08/09/2006 20:50:00 0.4 0.2 1.5 0.4 0.4 0.1 1.5 0.4 0.5 0.3 1.9 0.4 121 53 106 165 13.1 0 13.3 13 08/09/2006 21:00:00 0.6 0.4 1.9 0.4 0.5 0.4 1.9 0.4 0.8 0.5 2.6 0.4 185 76 318 165 13.1 0 13.3 13 08/09/2006 21:10:00 1.1 0.6 3 0.4 1.2 0.6 2.6 0.4 1.4 0.5 2.3 0.4 121 23 71 165 12.9 0 13.3 12.7 08/09/2006 21:20:00 1.9 1.1 4.9 0.4 2 1.2 4.9 0.4 2 1 4.6 0.4 298 24 295 165 13.1 0 13.3 12.7 08/09/2006 21:30:00 0.8 0.6 2.6 0.4 0.7 0.6 2.6 0.4 0.7 0.6 2.6 0.4 300 35 296 165 13.1 0 13.3 13 08/09/2006 21:40:00 0.5 0.3 1.9 0.4 0.4 0.2 1.5 0.4 0.6 0.5 2.3 0.4 95 69 356 165 13.1 0 13.3 13 08/09/2006 21:50:00 0.6 0.4 2.3 0.4 0.5 0.3 1.9 0.4 0.7 0.5 2.6 0.4 336 64 359 165 13.1 0 13.5 13 08/09/2006 22:00:00 0.6 0.6 3.4 0.4 0.6 0.6 3.4 0.4 0.7 0.6 3.4 0.4 318 39 320 165 13.1 0 13.3 13 08/09/2006 22:10:00 0.9 0.7 3.8 0.4 0.9 0.8 3.8 0.4 1.3 0.8 3.8 0.4 274 29 309 165 13.3 0 13.8 13 08/09/2006 22:20:00 0.5 0.4 2.3 0.4 0.5 0.4 2.3 0.4 0.5 0.3 1.5 0.4 261 33 281 165 13.1 0.1 13.3 13 08/09/2006 22:30:00 1.1 0.5 2.3 0.4 1.3 0.7 2.6 0.4 1.5 0.6 3.4 0.4 256 12 257 165 13.1 0 13.3 12.7 08/09/2006 22:40:00 1.5 0.6 3.4 0.4 1.8 0.8 3.4 0.4 2 0.6 3 0.4 260 15 287 165 13.1 0 13.3 13 08/09/2006 22:50:00 2.4 0.6 3.4 0.7 2.7 0.5 3.8 1.5 2.7 0.4 3.8 1.9 273 7 285 165 13.2 0 13.3 13 08/09/2006 23:00:00 2.7 0.7 3.8 0.4 3 0.5 4.2 1.5 2.9 0.6 4.2 0.7 275 8 274 165 13.3 0 13.3 13 08/09/2006 23:10:00 1 0.4 2.3 0.4 1 0.5 2.3 0.4 1.3 0.4 2.3 0.7 206 35 247 165 13.1 0.2 13.3 12.7 08/09/2006 23:20:00 0.9 0.4 2.3 0.4 0.8 0.5 2.3 0.4 1.6 0.4 2.6 0.7 147 22 164 165 12.5 0.1 12.7 12.2 08/09/2006 23:30:00 1.3 0.4 2.6 0.4 1.4 0.5 2.6 0.4 1.5 0.5 2.3 0.4 206 21 215 165 12.6 0 12.7 12.5 08/09/2006 23:40:00 1.3 0.4 2.6 0.4 1.4 0.4 2.6 0.4 1.7 0.3 2.3 0.7 236 22 279 165 12.7 0 13 12.7 08/09/2006 23:50:00 0.8 0.2 1.5 0.4 0.6 0.3 1.1 0.4 1.5 0.2 1.9 1.1 201 11 194 165 12.7 0 13 12.5 08/10/2006 00:00:00 0.6 0.4 2.3 0.4 0.5 0.4 2.3 0.4 1.1 0.3 2.3 0.4 203 22 270 165 12.5 0 12.7 12.5 08/10/2006 00:10:00 0.6 0.2 1.1 0.4 0.4 0.1 1.1 0.4 1.1 0.4 1.9 0.4 192 9 208 165 12.5 0 12.7 12.5 08/10/2006 00:20:00 0.5 0.2 1.1 0.4 0.5 0.2 1.1 0.4 1 0.4 1.9 0.4 189 10 169 165 12.5 0 12.7 12.2 08/10/2006 00:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.5 0.3 1.1 0.4 201 2 165 165 12.7 0 12.7 12.5 08/10/2006 00:40:00 0.4 0 0.7 0.4 0.4 0 0.4 0.4 0.4 0 0.7 0.4 200 2 198 165 12.3 0 12.7 11.9 08/10/2006 00:50:00 0.6 0.5 1.9 0.4 0.6 0.5 1.9 0.4 1.2 0.6 2.6 0.4 202 1 203 165 12.3 0.1 12.7 11.7 08/10/2006 01:00:00 1.9 0.2 2.3 1.1 2 0.3 2.6 1.5 2.6 0.2 3 2.3 220 9 202 165 12.3 0.2 12.7 11.9 08/10/2006 01:10:00 1.7 0.3 2.3 1.1 1.8 0.3 2.3 1.1 2.3 0.2 2.6 1.9 220 2 220 165 12.1 0.2 12.5 11.7 08/10/2006 01:20:00 1.2 0.4 2.6 0.4 1.3 0.5 2.6 0.4 1.9 0.3 2.6 1.5 237 11 242 165 12.3 0.1 12.5 11.9 08/10/2006 01:30:00 1.2 0.3 1.9 0.7 1.3 0.3 1.9 0.7 1.8 0.3 2.3 1.1 208 9 203 165 12.2 0.2 12.5 11.9 08/10/2006 01:40:00 0.8 0.5 1.9 0.4 0.8 0.5 1.9 0.4 1.5 0.4 2.3 0.7 204 2 205 165 12.3 0.2 12.5 11.9 08/10/2006 01:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0.1 1.1 0.4 206 12 165 165 12.4 0.1 12.7 11.7 08/10/2006 02:00:00 0.5 0.3 1.5 0.4 0.5 0.2 1.5 0.4 0.7 0.4 1.5 0.4 296 9 300 165 12.5 0.1 12.7 11.9 08/10/2006 02:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 300 2 165 165 12.4 0.1 12.7 11.9 08/10/2006 02:20:00 0.9 0.4 1.9 0.4 0.8 0.5 2.3 0.4 1.1 0.5 2.3 0.4 305 7 311 165 12.6 0.2 13 11.9 08/10/2006 02:30:00 0.4 0.2 1.1 0.4 0.5 0.2 1.5 0.4 0.6 0.4 1.5 0.4 297 13 318 165 12.7 0 13 12.2 08/10/2006 02:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 289 2 165 165 12.5 0 12.7 12.2 08/10/2006 02:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.7 0.4 273 20 165 165 12.4 0 12.7 11.9 08/10/2006 03:00:00 0.5 0.3 1.1 0.4 0.5 0.3 1.1 0.4 0.7 0.5 1.5 0.4 216 39 166 165 12.2 0.2 12.5 11.4 08/10/2006 03:10:00 0.8 0.3 1.5 0.4 0.8 0.3 1.5 0.4 0.9 0.3 1.5 0.4 165 1 169 165 11.7 0.2 11.9 11.1 08/10/2006 03:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.5 0.2 1.1 0.4 164 0 165 165 11.8 0.1 11.9 11.4 08/10/2006 03:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.5 0.3 1.5 0.4 148 22 165 165 11.9 0 12.2 11.4 08/10/2006 03:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0.2 1.1 0.4 116 0 165 165 12 0 12.2 11.7 08/10/2006 03:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.5 0.3 1.5 0.4 116 0 165 165 12.2 0 12.5 11.9 08/10/2006 04:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.5 0.3 1.5 0.4 116 0 165 165 12.1 0 12.2 11.7 08/10/2006 04:10:00 1.1 0.5 1.9 0.4 1.2 0.6 2.3 0.4 1.4 0.6 2.3 0.4 114 1 114 165 12.3 0 12.5 12.2 08/10/2006 04:20:00 1.8 0.3 2.3 1.5 1.9 0.3 2.6 1.5 2.1 0.2 2.6 1.5 120 5 116 165 12.3 0 12.5 11.9 08/10/2006 04:30:00 1.6 0.2 1.9 1.1 1.7 0.2 2.3 1.1 2 0.2 2.3 1.5 125 1 126 165 12.2 0 12.2 11.9 08/10/2006 04:40:00 1.8 0.3 2.6 1.1 1.9 0.3 2.6 1.1 2.1 0.3 2.6 1.5 125 1 125 165 12.1 0 12.5 11.9 08/10/2006 04:50:00 2 0.3 2.6 1.1 2.1 0.3 2.6 1.1 2.3 0.3 2.6 1.9 123 3 131 165 12.1 0 12.2 11.9 08/10/2006 05:00:00 1.9 0.3 2.6 1.1 1.9 0.3 2.6 1.5 2.2 0.3 3 1.5 137 2 131 165 12.1 0 12.2 11.9 08/10/2006 05:10:00 1.2 0.3 1.9 0.7 1.2 0.3 1.9 0.7 1.7 0.2 2.3 1.1 129 3 137 165 12.1 0 12.2 11.9 08/10/2006 05:20:00 1.5 0.2 2.3 1.1 1.6 0.2 2.3 1.1 1.8 0.2 2.3 1.1 126 1 127 165 11.9 0 12.2 11.9 08/10/2006 05:30:00 1.3 0.3 2.3 0.7 1.4 0.3 2.3 0.7 1.6 0.2 2.3 1.1 130 3 128 165 11.9 0 11.9 11.7 08/10/2006 05:40:00 1 0.5 2.3 0.4 1.1 0.6 2.6 0.4 1.6 0.4 2.3 0.7 125 12 134 165 12 0 12.2 11.9 08/10/2006 05:50:00 1.5 0.5 3 0.4 1.6 0.6 3 0.4 1.9 0.4 3 1.1 137 9 135 165 12.1 0 12.2 11.7 08/10/2006 06:00:00 2.4 0.4 3 1.5 2.5 0.3 3.4 1.5 2.6 0.3 3.4 1.9 142 7 133 165 12 0 12.2 11.7 08/10/2006 06:10:00 2.3 0.4 3.8 1.5 2.3 0.4 3.8 1.5 2.5 0.3 3.4 1.9 152 8 156 165 12 0 12.2 11.7 08/10/2006 06:20:00 2.7 0.4 3.8 1.9 2.7 0.3 3.8 1.9 2.9 0.3 3.8 2.3 153 9 158 165 11.9 0.2 12.2 11.4 08/10/2006 06:30:00 3 0.6 4.6 1.9 3 0.5 4.6 1.9 3.2 0.5 4.6 2.3 159 14 164 165 11.9 0.1 12.2 11.4 08/10/2006 06:40:00 3.5 0.6 4.9 2.3 3.4 0.6 4.9 2.3 3.6 0.5 4.9 2.3 156 6 154 165 11.9 0.1 12.2 11.4 08/10/2006 06:50:00 3.6 0.5 4.6 2.3 3.5 0.4 4.6 2.3 3.7 0.4 4.6 2.6 159 5 163 165 11.9 0.1 12.2 11.4 08/10/2006 07:00:00 3.1 0.4 3.8 1.9 3.1 0.4 3.8 2.3 3.1 0.3 3.8 2.3 162 5 160 165 11.9 0.2 12.2 11.4 08/10/2006 07:10:00 4 0.6 4.9 2.6 3.9 0.6 4.9 2.3 3.9 0.5 4.9 2.6 164 5 164 165 11.9 0.2 12.2 11.4 08/10/2006 07:20:00 4.1 0.5 5.3 2.6 4.1 0.5 4.9 2.6 4.1 0.5 5.3 2.6 160 11 162 165 12 0.1 12.2 11.4 08/10/2006 07:30:00 3.6 0.7 4.9 2.3 3.6 0.6 4.9 1.9 3.8 0.6 5.3 2.3 156 8 158 165 12.1 0 12.2 11.7 08/10/2006 07:40:00 3.7 0.7 5.3 1.5 3.7 0.7 4.9 1.9 3.8 0.6 4.9 1.9 153 5 158 165 12.1 0 12.2 11.7 08/10/2006 07:50:00 2.7 0.4 3.8 1.5 2.8 0.4 3.8 1.9 3 0.4 4.2 1.9 153 7 164 165 12.1 0 12.5 11.7 08/10/2006 08:00:00 3.5 0.6 4.6 2.3 3.5 0.6 4.6 2.3 3.7 0.5 4.9 2.3 144 8 145 165 12.3 0 12.5 11.9 08/10/2006 08:10:00 3.2 0.8 4.6 1.9 3.2 0.8 4.6 1.5 3.3 0.8 4.6 1.9 133 11 144 165 12.4 0.1 12.5 12.2 08/10/2006 08:20:00 3.5 0.4 4.6 1.9 3.6 0.5 4.2 1.9 3.4 0.4 4.6 2.3 123 5 128 165 12.4 0 12.5 12.2 08/10/2006 08:30:00 3.8 0.4 4.6 2.3 3.9 0.5 4.9 2.6 3.8 0.5 4.9 2.6 115 5 117 165 12.5 0 12.7 12.5 08/10/2006 08:40:00 3.8 0.5 5.3 2.3 3.9 0.5 5.3 2.3 3.8 0.6 5.7 2.3 113 8 112 165 12.5 0.1 12.7 12.5 08/10/2006 08:50:00 4.2 0.4 5.3 3.4 4.3 0.4 5.3 3.4 4.3 0.4 5.7 3 121 6 121 165 12.2 0 12.5 11.9 08/10/2006 09:00:00 2.3 0.8 4.2 0.4 2.3 0.9 4.2 0.4 2.6 0.7 4.2 1.1 117 6 112 165 12.1 0 12.7 11.9 08/10/2006 09:10:00 1.4 0.5 2.6 0.4 1.1 0.6 2.6 0.4 1.6 0.5 2.3 0.4 102 13 110 165 12.3 0 12.5 11.9 08/10/2006 09:20:00 2.5 0.5 3.4 0.7 2.5 0.6 3.4 0.7 2.2 0.5 3.4 0.7 96 11 102 165 12.5 0 12.7 11.9 08/10/2006 09:30:00 1.9 0.6 3 0.4 1.9 0.7 3.4 0.4 2.2 0.5 3.8 1.1 71 17 78 165 13 0.1 13.3 12.7 08/10/2006 09:40:00 2.4 0.6 3.8 1.1 2.2 0.7 3.8 0.4 2.4 0.7 4.2 0.7 84 33 105 165 13.6 0.1 14.1 13 08/10/2006 09:50:00 3.4 0.5 4.6 2.3 3.4 0.5 4.6 2.3 3.5 0.6 4.9 1.5 91 23 95 165 13.9 0 14.1 13.5 08/10/2006 10:00:00 2.7 0.6 4.9 1.5 2.6 0.6 4.9 0.7 2.9 0.5 4.6 1.5 39 15 55 165 13.7 0 13.8 13.5 08/10/2006 10:10:00 2.5 0.6 3.8 0.4 2.3 0.7 3.8 0.4 2.5 0.7 4.2 0.4 28 14 29 165 13.3 0 13.8 13 08/10/2006 10:20:00 2.7 0.5 3.8 1.1 2.4 0.6 3.4 0.7 3 0.4 4.2 1.9 19 8 14 165 13.1 0 13.5 13 08/10/2006 10:30:00 2.6 0.4 3.8 1.1 2.3 0.6 3.4 0.7 2.9 0.5 4.2 1.9 19 11 18 165 13.1 0 13.3 13 08/10/2006 10:40:00 2.7 0.4 3.8 1.9 2.5 0.5 3.4 1.5 3.2 0.4 4.2 1.9 22 6 22 165 13.1 0 13.3 13 08/10/2006 10:50:00 1.9 0.5 3 0.4 1.5 0.6 3 0.4 2.2 0.5 3.4 1.1 11 13 18 165 13.7 0.2 14.1 13 08/10/2006 11:00:00 1.9 0.4 3 1.1 1.4 0.6 3 0.4 2.3 0.4 3 1.1 8 12 356 165 14.4 0.2 14.6 13.8 08/10/2006 11:10:00 2.1 0.4 3 1.1 1.6 0.5 3 0.4 2.6 0.3 3.4 1.9 350 8 347 165 14.5 0.2 14.9 14.1 08/10/2006 11:20:00 1.8 0.3 2.6 1.1 1.3 0.5 2.3 0.4 2.4 0.3 3.4 1.9 347 8 340 165 13.5 0.3 14.6 13 08/10/2006 11:30:00 2 0.3 3 1.1 1 0.5 2.6 0.4 2.6 0.3 3.4 1.9 355 4 3 165 12.7 0.1 13.3 12.5 08/10/2006 11:40:00 1.9 0.4 2.6 1.1 1.2 0.4 2.3 0.4 2.4 0.5 3.4 1.5 359 6 2 165 12.1 0 12.5 11.7 08/10/2006 11:50:00 0.6 0.3 1.5 0.4 0.4 0.2 1.5 0.4 0.9 0.5 1.9 0.4 341 4 355 165 12.1 0.1 12.5 11.9 08/10/2006 12:00:00 0.5 0.2 1.1 0.4 0.4 0 0.7 0.4 0.5 0.2 1.1 0.4 190 36 203 165 12.6 0.1 13 12.2 08/10/2006 12:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.7 0.4 164 22 165 165 12.9 0 13.5 12.7 08/10/2006 12:20:00 0.5 0.3 1.9 0.4 0.4 0.3 1.9 0.4 0.7 0.5 2.6 0.4 214 35 168 165 13.1 0 13.3 13 08/10/2006 12:30:00 1 0.4 1.9 0.4 0.7 0.4 1.9 0.4 1.1 0.5 2.3 0.4 173 10 177 165 13.1 0.1 13.3 13 08/10/2006 12:40:00 1.4 0.5 2.3 0.4 1.2 0.6 2.3 0.4 1.5 0.5 2.3 0.4 166 9 159 165 12.9 0 13 12.7 08/10/2006 12:50:00 2.2 0.8 3.8 0.4 2 0.9 3.8 0.4 2.5 0.8 3.8 0.4 171 6 173 165 12.9 0 13 12.7 08/10/2006 13:00:00 3.4 0.3 4.2 2.6 3.3 0.4 4.2 2.3 3.6 0.3 4.6 3 163 5 162 165 12.7 0 12.7 12.2 08/10/2006 13:10:00 3.6 0.4 4.9 2.6 3.4 0.4 4.9 2.6 3.6 0.5 5.3 2.6 164 5 166 165 12.4 0 12.7 11.9 08/10/2006 13:20:00 3.2 0.3 3.8 2.3 3.1 0.3 3.8 1.9 3.3 0.4 4.2 2.3 168 5 165 165 12.4 0 12.5 12.2 08/10/2006 13:30:00 3.4 0.6 4.6 1.5 3.4 0.6 4.6 1.5 3.6 0.6 4.9 1.9 167 10 157 165 12.4 0 12.5 12.2 08/10/2006 13:40:00 3.2 0.5 4.6 1.9 3.2 0.5 4.2 1.9 3.5 0.4 4.2 2.6 159 13 153 165 12.5 0 12.7 12.2 08/10/2006 13:50:00 2.8 0.4 3.8 1.9 2.8 0.4 3.8 1.9 3.1 0.3 3.8 2.3 151 8 152 165 12.4 0 12.5 12.2 08/10/2006 14:00:00 3.5 0.4 4.9 2.6 3.5 0.4 4.6 2.6 3.7 0.4 4.9 3 150 10 163 165 12.4 0 12.7 11.9 08/10/2006 14:10:00 3.2 0.8 4.9 1.5 3.1 0.9 4.6 1.1 3.2 0.7 4.9 1.1 159 7 167 165 12.3 0 12.5 11.9 08/10/2006 14:20:00 2.6 0.5 3.8 1.1 2.6 0.5 3.8 1.5 2.8 0.4 3.8 1.9 166 8 165 165 12.4 0 12.5 11.9 08/10/2006 14:30:00 2.9 0.7 4.2 1.1 2.9 0.6 4.2 1.1 3.1 0.7 4.6 1.5 166 7 170 165 12.5 0 12.7 12.5 08/10/2006 14:40:00 2.4 0.3 3 1.5 2.3 0.3 3 1.5 2.7 0.4 3.4 1.9 172 9 178 165 12.6 0 12.7 12.5 08/10/2006 14:50:00 2.5 0.4 3.8 1.9 2.5 0.4 3.8 1.9 2.9 0.4 3.8 2.3 168 11 176 165 12.7 0 13 12.7 08/10/2006 15:00:00 2.8 0.3 3.8 1.9 2.8 0.3 3.8 1.9 3.1 0.3 3.8 2.3 165 10 171 165 12.7 0 12.7 12.5 08/10/2006 15:10:00 2.9 0.3 3.8 1.9 2.8 0.3 3.4 1.5 3.2 0.3 4.2 2.3 166 11 171 165 12.7 0 13 12.5 08/10/2006 15:20:00 3.6 0.5 4.6 1.9 3.4 0.4 4.2 1.9 3.8 0.5 4.9 2.6 170 4 176 165 12.7 0 13 12.5 08/10/2006 15:30:00 3.8 0.6 5.3 2.3 3.7 0.5 4.9 2.3 4 0.5 5.3 3 168 7 173 165 12.7 0 13 12.5 08/10/2006 15:40:00 4.1 0.5 5.3 2.6 4 0.5 5.3 3 4.3 0.5 5.3 3 162 8 164 165 12.5 0 12.7 12.5 08/10/2006 15:50:00 4.7 0.8 6.5 2.6 4.5 0.8 6.1 3 4.8 0.7 6.5 3.4 162 9 165 165 12.4 0 12.7 12.2 08/10/2006 16:00:00 4.8 0.6 6.5 3.4 4.6 0.6 6.1 3 4.9 0.6 6.8 3.8 165 8 164 165 12.4 0 12.7 12.2 08/10/2006 16:10:00 5.3 0.5 6.5 4.2 5.1 0.5 6.5 4.2 5.5 0.5 6.8 4.6 169 5 176 165 12.3 0 12.5 12.2 08/10/2006 16:20:00 5.2 0.7 6.8 3.8 5.1 0.6 6.5 3.8 5.2 0.6 6.8 3.8 170 7 166 165 12.3 0 12.5 11.9 08/10/2006 16:30:00 6 0.7 8 4.2 5.8 0.7 7.6 4.2 6.1 0.7 8 4.6 167 9 171 165 12.1 0 12.5 11.9 08/10/2006 16:40:00 6.1 0.5 7.6 4.9 5.9 0.5 7.2 4.6 6 0.5 7.2 4.9 167 5 168 165 12.1 0 12.5 11.9 08/10/2006 16:50:00 6.8 0.7 8.4 4.9 6.5 0.6 7.6 4.9 6.6 0.5 8 5.3 168 9 169 165 12.1 0 12.5 11.9 08/10/2006 17:00:00 7.6 0.7 9.1 5.7 7.3 0.6 8.8 5.7 7.3 0.6 8.8 5.7 174 6 180 165 12 0 12.2 11.9 08/10/2006 17:10:00 8 0.8 10.3 6.5 7.8 0.7 9.5 6.1 8 0.7 9.5 6.1 176 6 174 165 11.9 0 12.2 11.7 08/10/2006 17:20:00 7.3 1 9.9 4.6 7.1 0.9 9.5 4.6 7.5 1 9.5 4.9 178 5 189 165 11.9 0 12.2 11.7 08/10/2006 17:30:00 6.7 0.7 8.4 4.6 6.5 0.6 8 4.6 6.7 0.7 8 4.9 175 7 184 165 11.8 0 11.9 11.7 08/10/2006 17:40:00 6 1 8.4 3.4 5.9 1 8 3.4 6.1 1 8.4 3.4 180 7 184 165 11.7 0.1 11.9 11.4 08/10/2006 17:50:00 6.6 1 8.8 3.8 6.4 1 8.4 3.8 6.7 1.1 9.1 4.2 177 9 171 165 11.5 0.1 11.7 11.1 08/10/2006 18:00:00 7.7 0.8 9.1 6.1 7.5 0.7 8.8 5.7 7.7 0.9 9.5 5.7 177 6 166 165 11.5 0.1 11.7 11.1 08/10/2006 18:10:00 8.8 1 11.1 6.5 8.5 1 10.7 6.1 8.9 1.1 11.1 6.1 175 6 169 165 11.4 0.1 11.7 11.1 08/10/2006 18:20:00 8.8 0.9 10.7 6.5 8.4 0.8 10.3 6.5 8.7 0.8 10.7 6.8 173 6 179 165 11.3 0.1 11.7 10.9 08/10/2006 18:30:00 8.9 0.7 10.3 7.2 8.5 0.6 9.9 6.8 8.8 0.6 10.7 7.2 171 6 167 165 11.3 0.1 11.7 10.9 08/10/2006 18:40:00 9.6 0.5 10.7 7.2 9.3 0.4 10.3 7.6 9.7 0.6 10.7 7.6 167 4 167 165 11.1 0.3 11.7 10.9 08/10/2006 18:50:00 9.3 0.8 11.1 7.2 9.1 0.8 10.7 6.8 9.4 0.8 11.1 7.2 166 17 165 165 11.2 0.2 11.4 10.6 08/10/2006 19:00:00 8.2 0.6 10.3 6.8 8 0.5 9.9 6.8 8.2 0.5 9.9 6.8 169 5 183 165 11.3 0.1 11.4 10.9 08/10/2006 19:10:00 9.8 0.7 11.1 7.2 9.5 0.7 10.7 7.2 9.9 0.8 11.5 7.2 167 9 171 165 11.3 0.1 11.7 10.9 08/10/2006 19:20:00 9.9 0.7 11.8 8 9.5 0.7 11.8 8.4 10.1 0.7 12.6 8.4 171 11 173 165 11.3 0 11.4 11.1 08/10/2006 19:30:00 10.2 1 12.2 7.6 9.8 0.9 11.8 7.2 10 0.9 12.6 7.6 169 5 171 165 11.1 0 11.4 11.1 08/10/2006 19:40:00 11.4 0.7 13 9.1 10.9 0.7 12.6 9.1 11.4 0.7 13 8.8 171 5 171 165 11.1 0 11.1 10.9 08/10/2006 19:50:00 10.5 0.9 12.6 8 10 0.9 11.8 8 10.5 1 12.6 7.2 168 10 190 165 11 0 11.1 10.9 08/10/2006 20:00:00 9.8 1 11.8 7.6 9.4 1 11.5 7.6 9.9 1 11.8 7.2 163 17 162 165 10.9 0 11.1 10.9 08/10/2006 20:10:00 10 0.8 11.8 7.2 9.6 0.7 11.1 7.2 10.1 0.9 11.8 7.2 170 12 163 165 10.9 0 11.1 10.6 08/10/2006 20:20:00 9.1 1.3 11.1 4.9 8.7 1.2 10.3 4.6 9 1.2 11.1 5.3 173 14 172 165 11 0 11.1 10.6 08/10/2006 20:30:00 7.3 0.9 9.5 5.3 7 0.8 8.8 5.3 7.3 0.9 9.5 5.3 171 6 175 165 11.1 0 11.4 10.9 08/10/2006 20:40:00 7 0.8 8.4 4.9 6.7 0.6 8.4 4.9 6.8 0.7 8.4 5.3 172 12 172 165 11.1 0 11.4 10.6 08/10/2006 20:50:00 6.9 0.6 8.4 4.9 6.6 0.6 8 4.9 7 0.5 8.4 5.7 167 4 168 165 11.1 0 11.4 10.6 08/10/2006 21:00:00 6.2 0.5 7.6 4.9 6 0.5 7.2 4.9 6.4 0.5 7.6 4.9 171 7 166 165 11.1 0 11.1 10.6 08/10/2006 21:10:00 6 0.5 7.2 4.6 5.8 0.5 7.2 4.6 6.1 0.5 7.2 4.9 174 6 179 165 11.1 0 11.4 10.6 08/10/2006 21:20:00 5.3 0.4 6.1 4.2 5 0.4 6.1 3.8 5.4 0.4 6.1 4.2 166 5 163 165 11.1 0 11.4 10.9 08/10/2006 21:30:00 5.6 0.6 7.2 3.8 5.4 0.6 6.8 3.8 5.7 0.7 7.6 4.2 175 5 176 165 11.1 0 11.4 10.9 08/10/2006 21:40:00 7 1.1 8.4 4.2 6.8 1 8 4.2 7.2 1.1 8.8 4.2 172 6 167 165 11.2 0 11.4 10.9 08/10/2006 21:50:00 4.1 1.1 6.1 2.3 4.1 1 5.7 2.3 4.3 1.1 6.1 2.3 177 5 175 165 11.2 0 11.4 10.9 08/10/2006 22:00:00 5.1 0.5 6.1 3 4.9 0.4 6.1 3 5.3 0.5 6.5 3.8 175 4 176 165 11.2 0 11.4 10.6 08/10/2006 22:10:00 5.8 1.2 8.4 3.4 5.5 1.2 8.4 3 5.8 1.2 8.4 3.4 169 14 170 165 11.2 0 11.4 10.6 08/10/2006 22:20:00 6.8 0.7 8.8 5.3 6.5 0.7 8.4 5.3 6.9 0.7 8.8 5.3 170 17 165 165 11.1 0 11.4 10.9 08/10/2006 22:30:00 5.3 0.4 6.1 4.6 5 0.4 5.7 4.2 5.3 0.4 6.5 4.2 169 4 167 165 11.1 0 11.4 10.9 08/10/2006 22:40:00 3.7 0.7 4.9 1.5 3.6 0.7 4.6 1.9 3.9 0.7 5.3 2.3 170 6 164 165 11.1 0 11.4 10.9 08/10/2006 22:50:00 3.4 0.4 4.6 2.3 3.3 0.4 4.6 2.3 3.3 0.4 4.2 2.6 172 12 181 165 11.1 0 11.4 10.9 08/10/2006 23:00:00 3.6 0.5 5.3 2.3 3.4 0.5 4.9 2.3 3.7 0.4 4.6 2.6 167 10 179 165 11.1 0 11.4 10.9 08/10/2006 23:10:00 4 0.6 5.3 1.9 3.9 0.6 4.9 1.9 4.1 0.5 4.9 2.3 165 6 180 165 11.1 0 11.4 10.6 08/10/2006 23:20:00 1.6 0.9 3.8 0.4 1.6 0.9 3.8 0.4 1.9 0.6 3.4 0.4 184 20 221 165 11.1 0 11.4 10.9 08/10/2006 23:30:00 1 0.8 4.2 0.4 1.1 0.8 4.2 0.4 1.3 0.7 4.6 0.4 217 33 215 165 11.1 0.1 11.4 10.9 08/10/2006 23:40:00 2.6 1.5 6.1 0.4 2.6 1.5 5.3 0.4 2.9 1.2 5.3 0.4 181 32 162 165 11.2 0 11.4 10.9 08/10/2006 23:50:00 4 1.1 6.1 1.1 3.9 1 6.1 1.1 3.8 1.1 6.1 0.7 182 15 192 165 11.3 0 11.7 10.9 08/11/2006 00:00:00 4.8 1.1 6.8 1.9 4.6 1 6.5 1.9 4.8 1.1 6.8 3 173 9 174 165 11.4 0 11.7 11.1 08/11/2006 00:10:00 6.4 1.1 10.3 4.2 6.2 1.2 10.3 3.8 6.6 1.1 9.9 4.2 153 19 129 165 11.4 0 11.7 11.1 08/11/2006 00:20:00 7.8 0.9 9.9 4.2 7.6 0.9 9.5 4.2 7.6 1 9.9 4.9 168 13 156 165 11.2 0 11.4 10.6 08/11/2006 00:30:00 6.8 1 9.9 4.9 6.4 0.9 9.5 4.6 6.6 1 9.1 4.6 169 8 171 165 11.3 0.1 11.7 10.9 08/11/2006 00:40:00 4.5 0.7 6.8 3 4.3 0.7 6.1 3 4.5 0.8 6.1 3 174 8 192 165 11.3 0.1 11.7 10.9 08/11/2006 00:50:00 4.7 0.5 5.7 3.4 4.5 0.5 5.7 3 4.8 0.6 6.1 3 166 7 171 165 11.3 0.1 11.7 10.6 08/11/2006 01:00:00 4.6 0.7 6.5 2.6 4.5 0.6 6.1 2.3 4.7 0.6 6.5 3 159 8 165 165 11.3 0.1 11.7 10.9 08/11/2006 01:10:00 4.5 0.7 5.7 2.6 4.4 0.6 5.3 2.6 4.4 0.6 5.7 2.6 191 12 196 165 11.5 0 11.7 11.1 08/11/2006 01:20:00 3.7 0.7 4.6 1.5 3.8 0.7 4.6 1.5 4.1 0.7 5.3 2.3 204 3 205 165 11.7 0 11.9 11.4 08/11/2006 01:30:00 2.7 0.3 3.4 1.9 2.8 0.3 3.8 2.3 2.9 0.3 3.8 2.3 210 5 216 165 11.7 0 11.9 11.1 08/11/2006 01:40:00 0.8 0.7 2.6 0.4 0.8 0.7 2.6 0.4 1.2 0.6 3 0.4 196 16 211 165 11.7 0.1 11.9 11.1 08/11/2006 01:50:00 0.7 0.5 2.3 0.4 0.6 0.5 2.3 0.4 1.3 0.5 2.3 0.4 196 6 191 165 11.7 0 11.9 10.9 08/11/2006 02:00:00 1.4 0.7 3 0.4 1.5 0.8 3.4 0.4 1.6 0.7 3.4 0.4 274 33 291 165 11.5 0 11.9 10.9 08/11/2006 02:10:00 1.3 0.9 3 0.4 1.4 1 3.4 0.4 1.4 1 3 0.4 309 9 305 165 11.3 0.2 11.7 10.6 08/11/2006 02:20:00 0.8 0.6 2.6 0.4 0.8 0.6 3 0.4 0.9 0.7 2.6 0.4 294 9 285 165 11.1 0.1 11.4 10.6 08/11/2006 02:30:00 2.1 0.6 3.4 0.7 2.2 0.6 3.4 1.1 2.1 0.6 3.4 1.1 292 6 286 165 11.2 0 11.7 10.9 08/11/2006 02:40:00 2.3 0.8 3.8 1.1 2.4 0.7 3.8 1.1 2.7 0.7 3.8 1.1 259 17 243 165 11.7 0.1 11.9 11.4 08/11/2006 02:50:00 1.8 0.6 3.4 0.4 2.2 0.5 3.4 0.4 2.7 0.5 4.2 1.5 255 8 235 165 12 0 12.2 11.4 08/11/2006 03:00:00 1.3 0.4 2.3 0.4 1.8 0.6 3 0.4 2.1 0.4 3 1.5 254 13 262 165 11.9 0.1 12.2 11.1 08/11/2006 03:10:00 1.8 0.3 2.6 1.1 1.9 0.3 2.6 1.1 2.3 0.3 3 1.5 237 7 228 165 11.8 0.1 11.9 11.4 08/11/2006 03:20:00 1.5 0.4 2.3 0.7 1.6 0.4 2.3 1.1 2.1 0.3 2.6 1.5 246 5 239 165 12.1 0 12.2 11.7 08/11/2006 03:30:00 1.9 0.6 3 1.1 2 0.6 3 1.1 2.4 0.5 3.4 1.5 234 13 219 165 12.3 0 12.5 11.7 08/11/2006 03:40:00 2.6 0.3 3.4 1.5 2.8 0.3 3.8 1.9 3 0.2 3.8 2.3 242 11 250 165 12.1 0 12.5 11.7 08/11/2006 03:50:00 2.2 0.6 3.4 0.7 2.7 0.5 3.8 1.1 2.7 0.5 3.8 1.5 265 8 274 165 12.2 0 12.5 11.7 08/11/2006 04:00:00 3.7 0.3 4.2 3 3.7 0.3 4.6 3.4 3.4 0.5 4.2 2.3 290 7 290 165 12.2 0 12.2 11.7 08/11/2006 04:10:00 3.3 0.5 4.2 2.3 3.4 0.5 4.2 2.3 2.9 0.5 4.2 1.9 306 3 303 165 12.3 0 12.5 11.7 08/11/2006 04:20:00 0.8 0.6 2.6 0.4 0.8 0.6 2.6 0.4 1.2 0.5 2.6 0.4 306 13 314 165 12.3 0.1 12.5 11.9 08/11/2006 04:30:00 1.4 0.6 2.6 0.4 1.3 0.6 2.6 0.4 1.9 0.6 3 0.4 214 13 207 165 12.3 0.1 12.5 11.7 08/11/2006 04:40:00 1.3 0.3 1.9 0.7 1.1 0.5 1.9 0.4 2 0.3 2.6 1.5 198 3 201 165 12 0.1 12.5 11.4 08/11/2006 04:50:00 0.8 0.4 1.9 0.4 0.8 0.4 1.5 0.4 1.1 0.5 2.3 0.4 253 32 282 165 11.9 0 12.2 11.7 08/11/2006 05:00:00 1 0.5 1.9 0.4 0.9 0.5 1.9 0.4 1.6 0.5 2.6 0.4 326 16 316 165 11.7 0 12.2 11.4 08/11/2006 05:10:00 0.6 0.3 1.1 0.4 0.4 0.2 1.1 0.4 1.1 0.6 1.9 0.4 354 9 344 165 11.6 0.1 11.9 11.1 08/11/2006 05:20:00 1 0.6 2.3 0.4 0.9 0.5 1.9 0.4 1.4 0.7 2.6 0.4 127 72 165 165 11.9 0 12.2 11.4 08/11/2006 05:30:00 0.8 0.3 1.5 0.4 0.4 0.2 1.1 0.4 1.4 0.2 1.9 0.7 190 12 196 165 11.9 0 12.2 11.4 08/11/2006 05:40:00 1.8 0.5 2.3 0.7 1.8 0.6 2.6 0.4 2.3 0.5 3 1.5 204 5 210 165 12.1 0 12.2 11.7 08/11/2006 05:50:00 1.1 0.6 2.3 0.4 1.1 0.6 2.3 0.4 1.7 0.5 2.6 0.7 223 23 197 165 12.1 0 12.2 11.7 08/11/2006 06:00:00 0.8 0.5 1.9 0.4 0.7 0.5 1.9 0.4 0.9 0.6 2.3 0.4 224 51 277 165 12.1 0 12.2 11.7 08/11/2006 06:10:00 0.4 0 0.7 0.4 0.4 0 0.4 0.4 0.6 0.4 1.5 0.4 165 0 165 165 11.7 0.2 11.9 11.4 08/11/2006 06:20:00 0.5 0.3 1.5 0.4 0.5 0.3 1.5 0.4 0.6 0.4 1.9 0.4 256 64 252 165 11.9 0.2 12.5 11.4 08/11/2006 06:30:00 0.8 0.4 1.9 0.4 0.8 0.4 1.9 0.4 1.1 0.5 1.9 0.4 242 5 252 165 12.3 0 12.5 11.7 08/11/2006 06:40:00 0.4 0.1 1.1 0.4 0.4 0 0.4 0.4 0.5 0.4 1.5 0.4 235 9 209 165 12.6 0.2 13 11.7 08/11/2006 06:50:00 1.1 0.4 1.9 0.4 0.9 0.4 1.9 0.4 1.5 0.5 2.3 0.7 170 8 173 165 12.5 0.2 13 11.9 08/11/2006 07:00:00 1.2 0.6 2.3 0.4 1.2 0.6 2.3 0.4 1.5 0.6 2.3 0.4 155 11 162 165 12.5 0.4 13.5 11.7 08/11/2006 07:10:00 0.8 0.5 2.3 0.4 0.6 0.4 1.9 0.4 0.6 0.4 1.9 0.4 224 66 174 165 14.4 0.4 14.9 13.5 08/11/2006 07:20:00 1.3 0.6 3 0.4 1 0.6 2.6 0.4 1.4 0.8 3 0.4 191 17 165 165 15 0.1 15.5 14.6 08/11/2006 07:30:00 1.4 0.6 2.6 0.4 1.3 0.6 2.6 0.4 1.7 0.7 3.4 0.4 198 16 200 165 14.1 0.2 14.6 13.5 08/11/2006 07:40:00 1.7 0.5 3.8 0.7 1.8 0.6 3.8 0.7 2 0.5 3.4 0.4 252 21 269 165 14.3 0 14.6 14.1 08/11/2006 07:50:00 1.9 1 4.9 0.4 2 1.1 4.6 0.4 2.2 1 4.6 0.4 273 24 285 165 14.3 0 14.6 14.1 08/11/2006 08:00:00 2.9 0.6 4.6 1.5 2.9 0.5 4.2 1.9 3.1 0.5 4.9 1.9 229 19 239 165 13.8 0.2 14.4 13.3 08/11/2006 08:10:00 3 0.9 5.3 1.1 3.4 0.6 5.3 1.9 3.3 0.5 4.9 1.9 252 9 247 165 13.7 0.1 14.1 13.3 08/11/2006 08:20:00 2.8 0.8 4.9 1.1 2.9 0.7 5.3 1.5 3 0.6 4.9 1.9 245 12 252 165 14.1 0 14.6 13.8 08/11/2006 08:30:00 1.7 0.7 3 0.4 1.7 0.7 3.4 0.4 1.9 0.6 3 0.7 265 26 221 165 14.4 0.2 14.9 13.8 08/11/2006 08:40:00 1.2 0.6 3 0.4 1.3 0.6 3 0.4 1.4 0.6 3 0.4 275 17 286 165 14.6 0 14.9 14.6 08/11/2006 08:50:00 0.5 0.3 1.5 0.4 0.5 0.2 1.5 0.4 0.7 0.4 1.9 0.4 276 11 292 165 14.8 0 15.2 14.6 08/11/2006 09:00:00 0.6 0.5 1.9 0.4 0.5 0.4 1.9 0.4 1.1 0.5 2.3 0.4 179 33 169 165 14.8 0.1 15.2 14.6 08/11/2006 09:10:00 1.1 0.4 1.9 0.4 0.7 0.5 1.9 0.4 1.6 0.4 2.6 0.7 177 9 165 165 14.5 0 14.9 14.4 08/11/2006 09:20:00 1.7 0.6 2.6 0.4 1.4 0.7 2.6 0.4 2 0.5 3 1.1 152 7 159 165 14.7 0.1 15.2 14.6 08/11/2006 09:30:00 1.2 0.5 2.3 0.4 1 0.6 2.6 0.4 1.6 0.6 3 0.4 137 17 141 165 15.9 0.5 16.8 15.2 08/11/2006 09:40:00 2.2 0.6 3.8 0.7 2 0.6 3.4 0.7 2.5 0.7 4.2 1.1 139 20 163 165 15.3 0.7 16.8 14.6 08/11/2006 09:50:00 1.5 0.8 3 0.4 1.4 0.9 3 0.4 1.7 1 3.4 0.4 112 14 112 165 14.6 0.1 14.9 14.4 08/11/2006 10:00:00 1.6 0.5 2.6 0.4 1.4 0.6 2.6 0.4 2 0.6 3 0.4 36 26 64 165 14.9 0.3 15.7 14.6 08/11/2006 10:10:00 1.5 0.8 3.4 0.4 1.5 0.8 3.4 0.4 1.8 0.7 3.4 0.4 29 51 319 165 15.7 0.1 16 15.2 08/11/2006 10:20:00 2 0.9 4.2 0.4 1.9 0.9 4.2 0.4 2.3 0.8 4.2 0.4 35 32 58 165 16.4 0 16.8 16 08/11/2006 10:30:00 2.5 1 4.6 0.4 2.5 1 4.6 0.4 2.6 1 4.6 0.4 77 47 4 165 16.7 0.5 17.7 15.7 08/11/2006 10:40:00 3.5 0.5 4.6 1.9 3.5 0.6 4.9 1.9 3.7 0.6 5.3 1.9 121 10 117 165 15.2 0.3 16.3 14.9 08/11/2006 10:50:00 3.1 0.6 4.2 1.5 3 0.7 4.2 1.5 3.1 0.7 4.6 1.5 110 17 108 165 15.2 0.2 16.3 14.9 08/11/2006 11:00:00 1.6 0.9 3.8 0.4 1.6 0.9 3.8 0.4 1.8 0.8 3.8 0.4 49 51 75 165 16.4 0.4 17.1 15.5 08/11/2006 11:10:00 2.4 1 5.7 0.4 2.3 1.1 5.7 0.4 2.5 1.1 5.7 0.4 11 35 28 165 17.8 0.2 18.2 17.1 08/11/2006 11:20:00 1.3 0.8 3.8 0.4 1.2 0.9 3.8 0.4 1.5 0.9 4.2 0.4 33 47 87 165 17.8 0 18.2 17.4 08/11/2006 11:30:00 3.5 1.2 6.5 0.4 3.5 1.2 6.5 0.4 2.8 1.1 5.7 0.4 326 27 316 165 18.6 0.3 19.1 17.7 08/11/2006 11:40:00 1.7 0.8 3.4 0.4 1.7 0.8 3.4 0.4 1.6 0.8 4.2 0.4 202 94 317 165 18.2 0.4 18.8 17.1 08/11/2006 11:50:00 2.2 1.2 6.5 0.4 2.7 1.3 5.7 0.4 2.5 1.2 5.3 0.4 308 90 317 165 17.8 0.4 18.5 17.1 08/11/2006 12:00:00 4.8 1.5 8.8 0.4 5.1 1.4 8.8 0.4 4.4 1.5 8.4 0.4 287 47 295 165 18.3 0.2 18.8 18 08/11/2006 12:10:00 4.6 2 9.1 0.4 4.9 1.8 9.1 1.5 4.5 1.7 8.4 0.7 275 35 290 165 17.6 0.6 18.5 16.8 08/11/2006 12:20:00 1.7 1 4.6 0.4 1.8 1 4.2 0.4 1.9 1 3.8 0.4 171 107 349 165 16.8 0.3 17.4 16.3 08/11/2006 12:30:00 2.4 1.3 6.5 0.4 2.6 1.3 6.5 0.4 2.3 1.1 4.9 0.4 320 107 298 165 16.4 0.5 17.7 15.7 08/11/2006 12:40:00 2.9 0.9 4.9 0.7 3.2 0.8 5.3 0.7 2.8 0.7 4.2 0.7 291 16 300 165 18.2 0.1 18.5 17.7 08/11/2006 12:50:00 1.1 0.7 2.6 0.4 1.4 0.8 3 0.4 1.5 0.7 3.4 0.4 179 22 174 165 17.6 0.2 18.2 17.4 08/11/2006 13:00:00 0.9 0.7 3.4 0.4 1.1 0.8 3.8 0.4 1.3 0.8 4.2 0.4 329 36 287 165 17.6 0 18 17.4 08/11/2006 13:10:00 2.7 0.7 4.6 1.1 2.9 0.7 4.9 1.5 2.5 0.8 5.3 1.1 289 11 281 165 17 0.1 17.7 16.8 08/11/2006 13:20:00 1.9 0.6 3.4 0.4 2.3 0.6 3.8 0.4 1.9 0.8 3.8 0.4 286 28 286 165 17.2 0.1 17.4 16.8 08/11/2006 13:30:00 4 1 6.1 1.9 4.1 1 6.1 2.3 3.7 1 5.7 1.5 310 8 307 165 17.5 0 17.7 17.1 08/11/2006 13:40:00 4.3 1.1 7.2 2.6 4.5 1 7.2 2.6 3.7 0.9 6.5 1.9 297 10 296 165 17.7 0.2 18.2 17.1 08/11/2006 13:50:00 5.7 1.2 8.8 2.6 5.8 1.1 8.8 3.8 4.9 1.1 8.4 2.6 292 13 297 165 17.7 0.2 18.2 17.4 08/11/2006 14:00:00 7.3 1 9.5 4.6 7.3 1 9.5 4.6 6.4 1.2 9.1 3 307 10 303 165 17.2 0 17.7 16.8 08/11/2006 14:10:00 7.1 0.8 9.1 4.6 7 0.9 9.1 4.6 6.5 1 9.1 4.2 310 7 313 165 17 0 17.7 16.8 08/11/2006 14:20:00 6.9 1 9.9 4.2 6.8 1 10.3 4.2 6.3 1.1 9.5 3.8 310 7 302 165 17.6 0.4 18.5 17.1 08/11/2006 14:30:00 8.4 1 10.3 4.9 8.2 1 10.3 4.2 7.9 1.1 10.3 4.2 313 8 319 165 17.8 0.4 18.5 17.1 08/11/2006 14:40:00 7.7 1 9.9 4.9 7.6 1 9.9 4.9 6.6 1.1 9.5 4.2 304 10 290 165 17.1 0.2 18 16.6 08/11/2006 14:50:00 7.5 1.1 9.9 4.6 7.4 1.1 9.9 4.9 6.4 1 9.1 3.8 303 10 301 165 17 0.1 17.4 16.6 08/11/2006 15:00:00 7.6 1 10.3 3.8 7.5 1.1 10.3 3 6.5 1 9.1 3.8 305 8 300 165 16.4 0.1 16.8 16.3 08/11/2006 15:10:00 8.1 0.8 10.7 5.7 7.9 0.9 10.3 5.7 7.9 0.8 9.9 5.7 314 6 307 165 16.5 0.2 16.8 16 08/11/2006 15:20:00 6.8 0.8 8.8 4.9 6.7 0.9 8.8 4.6 6.3 1.1 8.8 3.4 310 8 309 165 15.9 0 16.3 15.7 08/11/2006 15:30:00 7 0.8 9.1 4.9 6.9 0.8 8.8 4.6 5.9 0.9 8.8 3.8 305 7 290 165 16 0 16.3 16 08/11/2006 15:40:00 6.9 0.8 8.8 4.9 6.7 0.8 8.8 4.6 5.9 0.9 8 3.4 305 7 307 165 16 0 16.3 16 08/11/2006 15:50:00 5.6 1 8 3 5.6 0.9 7.6 3.4 5.4 1 8 2.6 312 9 304 165 16.2 0 16.6 16.3 08/11/2006 16:00:00 4 0.8 6.5 1.9 4.1 0.7 6.8 2.3 3.7 0.9 6.8 1.9 310 9 321 165 17 0.4 18 16.3 08/11/2006 16:10:00 3.4 0.9 6.1 1.1 3.6 0.8 6.1 1.9 3.3 0.7 5.7 1.5 307 21 309 165 17.9 0.4 18.5 17.1 08/11/2006 16:20:00 3.9 0.9 6.1 1.9 4.6 0.9 6.8 1.9 4.4 1 6.5 2.3 271 13 247 165 16.9 0 17.4 16.8 08/11/2006 16:30:00 4.3 0.9 6.8 1.5 4.5 0.9 6.8 2.3 3.7 0.8 6.1 1.5 295 17 294 165 17.6 0.4 18.5 16.8 08/11/2006 16:40:00 4.4 1 6.5 1.5 4.6 1 6.8 1.9 3.2 1 5.7 0.7 304 17 296 165 18.6 0 18.8 18.2 08/11/2006 16:50:00 4.2 0.7 6.1 2.3 4.4 0.7 6.1 2.6 3.3 1 5.7 0.7 305 12 300 165 18.7 0 19.1 18.5 08/11/2006 17:00:00 4.6 0.9 6.8 1.9 4.8 0.9 6.8 1.5 3.6 1.1 6.5 0.7 305 12 306 165 18.8 0.2 19.4 18.5 08/11/2006 17:10:00 4.6 0.7 6.8 2.6 4.8 0.7 6.8 2.6 3.7 0.9 5.7 1.5 311 10 309 165 19.1 0.2 19.7 18.5 08/11/2006 17:20:00 3.5 1.1 6.8 0.7 3.7 1.1 7.2 0.7 3 1.2 6.5 0.7 307 17 312 165 19.5 0 20 19.4 08/11/2006 17:30:00 6.3 1.2 8.4 3.4 6.4 1.1 8.8 3.8 5.4 1.1 8.4 2.3 298 12 291 165 18.3 0.9 19.7 17.1 08/11/2006 17:40:00 7 0.8 8.8 4.6 7 0.8 9.1 4.6 6.5 1 8.8 3.4 286 7 290 165 16.6 0.4 17.4 16 08/11/2006 17:50:00 6.1 0.8 8 3.8 6.2 0.8 8.4 3.8 5.9 0.8 7.6 3.4 282 7 276 165 15.8 0 16 15.7 08/11/2006 18:00:00 4.9 1.1 8 1.1 5.5 0.8 8 2.6 5.3 0.9 8.4 3 278 9 280 165 15.4 0.2 16 15.2 08/11/2006 18:10:00 5.5 1.1 8.4 2.6 6.1 0.9 8.8 3.8 5.9 0.9 9.1 3.4 272 9 265 165 15.2 0 15.5 15.2 08/11/2006 18:20:00 3.3 1.5 6.5 0.4 3.6 1.3 6.5 0.4 3.3 1.3 6.5 0.7 200 32 196 165 14.5 0.5 15.2 13.3 08/11/2006 18:30:00 1.8 1.2 6.1 0.4 2.2 1.2 6.1 0.4 1.9 1.1 4.9 0.4 177 39 232 165 13 0.2 13.8 12.7 08/11/2006 18:40:00 4.2 2 8.4 0.7 4.8 1.8 8.4 1.5 4.6 1.7 8.4 1.1 267 13 276 165 14.4 0.2 14.6 13.5 08/11/2006 18:50:00 5.9 1.2 8.8 3 6.8 1.1 9.5 4.2 6.6 1.2 9.5 3 268 9 271 165 14.6 0 14.9 14.6 08/11/2006 19:00:00 6.4 0.9 8.8 3 6.4 0.9 8.8 4.2 5.6 1 8.4 3.4 295 11 288 165 14.8 0 15.2 14.6 08/11/2006 19:10:00 3.3 1.5 6.1 0.7 3.6 1.3 6.1 1.1 2.9 1.2 5.3 0.7 307 9 302 165 14.5 0 14.9 14.1 08/11/2006 19:20:00 3.3 0.8 4.9 0.7 3.5 0.8 5.3 1.5 2.6 0.7 4.2 0.7 296 10 302 165 13.9 0 14.4 13.8 08/11/2006 19:30:00 0.9 0.6 2.6 0.4 1.1 0.7 2.6 0.4 0.8 0.5 2.3 0.4 339 76 333 165 13.5 0.3 14.1 12.7 08/11/2006 19:40:00 0.8 0.5 2.3 0.4 0.8 0.5 2.3 0.4 1.2 0.7 3 0.4 81 76 13 165 12.8 0 13.3 12.7 08/11/2006 19:50:00 2.1 1 4.2 0.4 2.4 1 4.2 0.4 2.3 1 4.6 0.4 312 28 319 165 13.6 0 13.8 13.3 08/11/2006 20:00:00 3.3 1 5.3 0.7 3.5 0.9 5.3 0.7 3.3 0.9 5.3 1.1 306 12 315 165 13.8 0 14.1 13.5 08/11/2006 20:10:00 3.1 1 5.7 0.4 3.2 1 5.7 0.4 2.9 0.8 5.3 1.1 311 18 310 165 14 0 14.4 13.8 08/11/2006 20:20:00 4.5 1 6.5 2.6 4.7 1 6.5 2.6 4.4 1.1 6.5 1.9 288 8 287 165 13.9 0 14.1 13.8 08/11/2006 20:30:00 5.9 0.6 6.8 4.2 6 0.6 7.2 4.2 5.6 0.7 6.8 3.8 286 3 286 165 13.9 0 14.4 13.8 08/11/2006 20:40:00 2.7 1.9 6.1 0.4 3.2 2.1 6.1 0.4 3 1.7 6.1 0.4 225 49 285 165 13.3 0.6 14.1 12.2 08/11/2006 20:50:00 1.2 0.7 3 0.4 1.6 0.9 3.4 0.4 1.2 0.7 3 0.4 303 86 283 165 12.1 0.2 12.5 11.9 08/11/2006 21:00:00 2.3 0.6 3.8 0.7 3.1 0.4 4.6 2.3 3 0.3 4.2 2.3 264 11 271 165 13.1 0 13.3 12.5 08/11/2006 21:10:00 3 0.4 4.2 1.9 3.1 0.4 4.2 2.3 2.9 0.4 3.8 1.9 306 11 297 165 13.4 0 13.8 13.3 08/11/2006 21:20:00 2.8 0.5 3.8 1.9 2.9 0.5 3.8 1.9 2.8 0.5 4.2 1.5 309 5 307 165 13.5 0 13.5 13 08/11/2006 21:30:00 2 0.7 3.4 0.4 2.2 0.7 3.8 0.4 2.1 0.6 3.8 0.7 272 26 296 165 13.4 0 13.5 13 08/11/2006 21:40:00 2.2 0.5 3 0.7 2.4 0.5 3.4 1.1 2.5 0.5 3.4 1.1 287 17 292 165 13.4 0 13.5 13 08/11/2006 21:50:00 2.1 0.3 3 1.1 2.3 0.3 3 1.1 2.5 0.3 3.4 1.5 280 8 290 165 13.3 0 13.8 13 08/11/2006 22:00:00 3.2 0.7 4.9 1.9 3.3 0.8 4.9 1.9 3.1 0.8 4.9 1.5 291 10 282 165 13.5 0 13.5 13.3 08/11/2006 22:10:00 4 0.5 5.3 2.6 3.9 0.5 5.3 2.6 3.3 0.5 4.9 2.3 301 6 302 165 13.3 0 13.5 13.3 08/11/2006 22:20:00 2.7 0.6 3.8 1.1 2.8 0.5 3.8 1.5 2.7 0.5 4.2 1.5 281 9 278 165 13.3 0 13.5 13 08/11/2006 22:30:00 2.8 0.6 3.8 1.1 3 0.5 4.2 1.5 2.9 0.5 4.2 1.9 278 8 277 165 13.1 0 13.3 13 08/11/2006 22:40:00 2 0.8 3.8 0.4 2.4 0.8 3.8 0.4 2.4 0.7 3.8 0.4 263 18 281 165 13 0 13.3 12.7 08/11/2006 22:50:00 0.6 0.3 1.5 0.4 0.6 0.4 1.5 0.4 0.8 0.4 1.9 0.4 223 21 212 165 12.5 0 12.7 12.5 08/11/2006 23:00:00 1.1 0.8 3 0.4 1.2 0.9 3 0.4 1 0.6 3.4 0.4 216 32 245 165 12.3 0 12.5 12.2 08/11/2006 23:10:00 1.1 0.4 2.3 0.4 0.9 0.4 2.3 0.4 1.4 0.4 2.3 0.4 139 14 126 165 12.1 0 12.2 11.9 08/11/2006 23:20:00 0.7 0.4 1.9 0.4 0.5 0.4 2.6 0.4 1.1 0.5 2.3 0.4 190 49 273 165 12.1 0 12.2 11.9 08/11/2006 23:30:00 0.4 0.1 1.1 0.4 0.4 0 0.4 0.4 0.6 0.4 1.5 0.4 154 13 152 165 12.1 0 12.2 11.9 08/11/2006 23:40:00 0.4 0.2 1.1 0.4 0.4 0.2 1.5 0.4 0.6 0.4 1.5 0.4 259 9 265 165 12.3 0.1 12.5 11.9 08/11/2006 23:50:00 0.4 0.2 1.5 0.4 0.4 0.1 1.1 0.4 0.5 0.2 1.1 0.4 225 19 222 165 12.4 0 12.5 12.2 08/12/2006 00:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0.2 1.1 0.4 180 9 165 165 12.3 0 12.5 12.2 08/12/2006 00:10:00 0.6 0.2 1.1 0.4 0.4 0 0.4 0.4 0.9 0.5 1.9 0.4 136 15 126 165 12.1 0 12.7 11.7 08/12/2006 00:20:00 0.4 0.2 1.1 0.4 0.4 0.1 1.1 0.4 0.6 0.4 1.5 0.4 125 2 126 165 12 0 12.2 11.7 08/12/2006 00:30:00 0.4 0.1 1.1 0.4 0.4 0 0.4 0.4 0.5 0.3 1.5 0.4 151 41 214 165 12.2 0 12.5 11.7 08/12/2006 00:40:00 0.4 0.2 1.1 0.4 0.4 0 0.4 0.4 0.7 0.4 1.5 0.4 214 9 221 165 12.5 0 12.7 11.9 08/12/2006 00:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.6 0.3 1.1 0.4 169 8 165 165 12.3 0 12.5 11.9 08/12/2006 01:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 217 39 165 165 12.2 0 12.2 11.9 08/12/2006 01:10:00 0.4 0 0.7 0.4 0.4 0 0.4 0.4 0.4 0.1 1.1 0.4 206 23 230 165 12.3 0 12.5 11.7 08/12/2006 01:20:00 1.2 0.5 2.3 0.4 1.1 0.6 2.3 0.4 1.5 0.6 2.6 0.4 268 8 274 165 12.2 0.2 12.5 11.7 08/12/2006 01:30:00 1.5 0.5 2.3 0.4 1.4 0.5 2.3 0.4 1.7 0.6 2.6 0.4 287 9 270 165 12.2 0.2 12.5 11.7 08/12/2006 01:40:00 2.1 0.6 3 1.1 2.2 0.6 3 0.7 1.8 0.5 3 0.7 293 6 290 165 12.1 0.1 12.5 11.7 08/12/2006 01:50:00 1.7 0.7 3 0.4 1.7 0.8 3 0.4 1.9 0.7 3 0.7 287 2 287 165 12.1 0.2 12.5 11.7 08/12/2006 02:00:00 0.6 0.3 1.5 0.4 0.4 0.1 1.1 0.4 0.9 0.4 1.5 0.4 287 1 288 165 12.2 0.1 12.5 11.9 08/12/2006 02:10:00 1.5 0.8 3.4 0.4 1.7 0.9 3.4 0.4 1.8 1 3.4 0.4 266 13 276 165 12.3 0.2 12.5 11.9 08/12/2006 02:20:00 2.8 0.6 3.8 1.1 2.9 0.5 3.8 1.5 3 0.5 4.2 1.9 281 9 284 165 12.2 0.1 12.5 11.9 08/12/2006 02:30:00 2 0.5 3 0.4 2.1 0.4 3 1.1 2.2 0.4 3 1.1 302 20 275 165 11.9 0.2 12.2 11.1 08/12/2006 02:40:00 2.8 0.7 4.6 1.5 2.7 0.7 4.6 1.5 2.5 0.6 4.9 1.1 302 16 285 165 11.4 0 11.7 11.1 08/12/2006 02:50:00 4.2 0.3 5.3 3.4 4.2 0.4 5.3 3.4 3.7 0.6 5.7 2.3 290 4 280 165 11.5 0 11.7 11.1 08/12/2006 03:00:00 4.8 0.5 6.1 3.8 4.8 0.5 6.1 3.8 3.6 0.5 4.9 2.3 295 3 297 165 11.5 0 11.7 11.1 08/12/2006 03:10:00 5.2 0.5 6.5 3.8 5.2 0.5 6.5 3.8 3.8 0.4 4.9 2.6 299 3 297 165 11.6 0 11.9 11.1 08/12/2006 03:20:00 4.7 0.4 5.7 3.8 4.7 0.4 5.7 3.8 3.8 0.5 5.3 2.6 293 3 296 165 11.7 0 11.9 11.4 08/12/2006 03:30:00 4.7 0.3 5.7 4.2 4.7 0.3 5.3 4.2 3.5 0.4 5.3 2.6 296 3 295 165 11.7 0 11.9 11.4 08/12/2006 03:40:00 4.9 0.4 6.5 3.8 5 0.4 6.5 4.2 4.3 0.7 5.7 2.6 289 4 284 165 11.7 0 11.9 11.4 08/12/2006 03:50:00 5.7 0.3 6.1 4.9 5.7 0.3 6.1 4.9 5.4 0.4 6.5 4.2 287 2 287 165 11.7 0 11.9 11.1 08/12/2006 04:00:00 5.3 0.4 6.1 4.6 5.4 0.4 6.1 4.6 5.1 0.5 6.1 3.4 288 3 286 165 11.6 0 11.7 11.1 08/12/2006 04:10:00 5.2 0.4 6.1 4.6 5.2 0.4 6.1 4.6 5 0.4 6.1 4.2 285 3 286 165 11.5 0 11.7 11.1 08/12/2006 04:20:00 5.5 0.3 6.1 4.6 5.5 0.3 6.1 4.6 5.2 0.4 6.1 4.2 287 3 287 165 11.4 0 11.7 10.9 08/12/2006 04:30:00 4.9 0.3 5.7 4.2 5 0.4 5.7 4.2 5.1 0.3 5.7 4.2 281 3 282 165 11.4 0 11.7 10.9 08/12/2006 04:40:00 4 0.4 4.9 3 4.1 0.3 5.3 3.4 4.1 0.3 4.9 3.4 279 4 281 165 11.3 0 11.7 10.9 08/12/2006 04:50:00 3.8 0.4 4.6 2.3 4 0.3 4.9 3 4.1 0.4 4.9 3.4 274 4 284 165 11.3 0.1 11.7 10.9 08/12/2006 05:00:00 3.8 0.4 4.9 2.6 4 0.4 5.3 3 4 0.3 4.9 3.4 276 4 273 165 11.3 0.1 11.7 10.9 08/12/2006 05:10:00 4.1 0.6 5.7 2.3 4.3 0.5 5.7 3 4.2 0.5 5.7 3 275 6 275 165 11.4 0 11.7 10.9 08/12/2006 05:20:00 4 0.6 5.3 2.6 4.9 0.4 6.1 4.2 4.7 0.3 6.1 3.8 269 4 276 165 11.5 0 11.7 11.1 08/12/2006 05:30:00 5 1 7.6 3 6.9 0.9 8.8 4.9 6.5 0.8 8.4 4.9 267 2 271 165 11.6 0.1 11.9 10.9 08/12/2006 05:40:00 4.8 0.6 6.5 3 6.8 0.5 8 5.7 6.6 0.6 7.6 4.6 262 3 262 165 11.8 0.1 11.9 11.4 08/12/2006 05:50:00 4.7 0.6 6.5 3.4 7 0.4 8 6.1 6.8 0.5 8.4 4.9 264 3 265 165 11.9 0 12.2 11.4 08/12/2006 06:00:00 4.6 0.9 6.8 2.3 6.3 0.7 7.6 3.4 5.8 1 8 3.4 259 5 252 165 11.9 0.1 12.2 11.4 08/12/2006 06:10:00 3.6 0.7 6.5 2.3 5.7 0.6 7.2 4.6 5.3 0.7 6.8 3.8 262 4 269 165 11.7 0.1 11.9 11.4 08/12/2006 06:20:00 3.7 0.8 6.5 2.3 5.3 0.6 6.8 3.8 5 0.6 6.5 3 266 4 274 165 11.7 0 11.9 11.4 08/12/2006 06:30:00 3.5 0.9 5.3 1.5 4.2 0.5 5.3 3 3.9 0.5 5.3 2.3 274 10 281 165 11.7 0 11.9 11.4 08/12/2006 06:40:00 4.1 0.5 4.9 2.3 4.3 0.5 5.3 2.6 3.7 0.6 4.9 2.3 283 7 289 165 11.8 0.1 11.9 11.4 08/12/2006 06:50:00 3.9 0.8 5.3 1.1 3.9 0.7 5.3 1.5 3.5 0.7 5.3 1.9 283 8 285 165 11.9 0 12.2 11.7 08/12/2006 07:00:00 4.1 1 5.7 0.7 4.2 0.9 5.7 1.5 3.8 0.9 5.7 1.9 282 7 281 165 12 0 12.2 11.9 08/12/2006 07:10:00 2.9 1 4.9 0.4 3 1 4.9 0.4 2.5 1 4.6 0.4 282 17 284 165 12.1 0 12.2 11.7 08/12/2006 07:20:00 2 0.8 3.8 0.4 2.2 0.8 3.8 0.4 1.9 0.9 3.8 0.4 275 14 280 165 12.1 0 12.5 11.7 08/12/2006 07:30:00 3.5 0.9 6.1 1.5 3.6 0.9 6.1 1.5 3.2 0.8 5.3 1.9 290 12 286 165 12.3 0.1 12.5 11.7 08/12/2006 07:40:00 4.2 0.7 5.7 2.3 4.2 0.6 5.3 1.9 3.2 0.6 4.6 1.5 297 8 291 165 12.3 0.1 12.7 11.7 08/12/2006 07:50:00 4.2 0.6 5.7 2.6 4.2 0.6 6.1 2.6 3.3 0.6 4.9 1.5 301 9 305 165 12.6 0 13 12.2 08/12/2006 08:00:00 3.7 0.6 5.3 1.5 3.7 0.6 5.3 1.5 3 0.6 4.9 1.5 298 9 309 165 12.9 0 13 12.7 08/12/2006 08:10:00 3.2 0.5 4.6 1.9 3.1 0.5 4.6 1.9 2.5 0.5 4.2 1.1 296 11 303 165 13.1 0 13.3 13 08/12/2006 08:20:00 3.2 0.9 4.9 0.7 3.1 0.9 4.6 0.7 2.4 0.8 4.2 0.4 294 12 288 165 13.3 0 13.5 12.7 08/12/2006 08:30:00 2.4 1.3 4.9 0.4 2.3 1.4 4.6 0.4 1.8 1.1 3.8 0.4 331 94 313 165 13.7 0 13.8 13.3 08/12/2006 08:40:00 2.3 1.4 5.3 0.4 2.3 1.4 5.3 0.4 1.9 1.2 4.9 0.4 281 38 322 165 13.9 0.1 14.4 13.5 08/12/2006 08:50:00 3.7 1.1 6.1 0.4 3.7 1.1 6.1 0.4 3.1 1 5.7 0.4 305 14 309 165 14.3 0.2 14.9 14.1 08/12/2006 09:00:00 4.4 0.8 6.5 2.3 4.2 0.8 6.1 1.9 3.8 0.8 5.7 1.9 314 11 322 165 15.1 0 15.5 14.9 08/12/2006 09:10:00 3.5 1 5.7 0.4 3.4 1 5.7 0.4 3.1 1 5.3 0.4 315 12 322 165 14.6 0.1 15.2 14.6 08/12/2006 09:20:00 3.8 0.8 5.7 1.5 3.7 0.9 5.3 1.1 3.3 0.8 4.9 1.1 312 12 306 165 14.4 0 14.9 14.4 08/12/2006 09:30:00 4.4 0.7 6.1 2.6 4.3 0.8 6.1 2.3 3.5 0.8 5.7 1.5 310 8 312 165 14.8 0 15.2 14.6 08/12/2006 09:40:00 3.9 0.9 5.7 1.5 3.8 0.9 5.7 1.1 3.2 1.1 5.3 0.7 314 12 286 165 15 0 15.5 14.9 08/12/2006 09:50:00 4.1 0.6 5.7 2.3 4 0.6 5.7 2.3 3.5 0.7 5.3 1.5 308 11 328 165 15.5 0 15.7 15.5 08/12/2006 10:00:00 3.4 1 5.7 0.4 3.4 1 6.1 0.4 3 1 6.1 0.7 293 20 245 165 15.3 0.1 15.7 15.2 08/12/2006 10:10:00 3.1 1 4.9 0.4 3 1.1 4.9 0.4 2.4 1 4.9 0.4 300 22 304 165 15.2 0 15.5 15.2 08/12/2006 10:20:00 3.1 0.9 5.3 0.7 3.1 0.9 4.9 0.7 2.6 0.9 4.9 0.4 305 15 314 165 15.5 0.1 15.7 15.5 08/12/2006 10:30:00 3.8 0.8 6.5 1.5 3.7 0.8 6.1 1.5 3.2 0.9 5.7 0.4 314 15 313 165 15.7 0 16 15.7 08/12/2006 10:40:00 4.7 0.8 7.2 2.6 4.7 0.8 7.2 3 4.2 1 6.8 2.3 316 10 320 165 15.6 0.1 16 15.2 08/12/2006 10:50:00 3.9 0.9 6.1 1.9 3.8 1 6.1 1.5 3.4 0.8 6.1 1.9 323 15 342 165 15.3 0 15.5 15.2 08/12/2006 11:00:00 4.6 0.6 6.5 3.4 4.5 0.6 6.1 3 4 0.6 5.3 2.6 309 7 302 165 15.2 0 15.5 15.2 08/12/2006 11:10:00 4.8 0.7 7.2 2.6 4.8 0.8 7.2 2.6 4 0.7 5.7 2.3 308 8 295 165 15.2 0 15.5 15.2 08/12/2006 11:20:00 4 1.5 6.8 0.7 3.9 1.6 6.8 0.4 3.5 1.1 5.7 1.1 318 22 316 165 15.4 0 15.7 15.2 08/12/2006 11:30:00 2.2 0.9 4.2 0.4 1.9 1 4.2 0.4 2.1 0.8 4.2 0.4 328 27 319 165 15.5 0 16 15.5 08/12/2006 11:40:00 3 1 4.9 0.4 3 1.1 4.9 0.4 2.6 0.7 4.2 0.7 305 17 301 165 15.8 0.1 16 15.5 08/12/2006 11:50:00 2.7 0.9 4.6 0.4 2.7 1 4.6 0.4 2.5 0.7 4.6 0.4 309 19 293 165 16.4 0.2 16.8 16 08/12/2006 12:00:00 2.8 1 5.3 0.4 2.9 1.1 5.3 0.4 2.4 1 4.9 0.4 290 21 283 165 16.4 0 16.8 16.3 08/12/2006 12:10:00 4.4 1.1 7.2 1.5 4.4 1.1 7.2 1.5 3.9 1 6.5 1.9 299 16 298 165 16.6 0 16.8 16.6 08/12/2006 12:20:00 4.8 1 7.2 2.6 4.7 1 7.6 2.6 4.3 0.9 6.1 2.6 311 9 306 165 16.7 0 16.8 16.6 08/12/2006 12:30:00 4.8 0.8 6.8 3 4.7 0.8 6.5 3 4.1 0.8 6.1 2.3 296 11 283 165 16.6 0 17.1 16.3 08/12/2006 12:40:00 4.8 0.8 6.8 2.3 4.8 0.8 6.8 2.6 4.1 0.8 6.1 1.9 296 11 291 165 16.9 0 17.4 16.8 08/12/2006 12:50:00 5.2 1 7.6 2.3 5.1 1 7.2 2.3 4.5 0.9 6.8 2.3 305 10 293 165 16.7 0.1 17.1 16.6 08/12/2006 13:00:00 5.1 1 8.4 2.6 5.2 1 8.4 2.6 4.4 1.2 7.2 1.1 293 13 295 165 16.8 0.1 17.4 16.3 08/12/2006 13:10:00 4.6 0.8 6.5 2.6 4.6 0.7 6.5 2.3 4.2 0.8 6.8 1.9 300 19 277 165 16.4 0.2 16.8 16.3 08/12/2006 13:20:00 5.3 1.1 8 2.6 5.3 1 7.6 3 4.6 1.1 6.8 1.9 301 11 305 165 16.5 0.2 17.4 16.3 08/12/2006 13:30:00 4.9 1 7.2 2.6 5 0.9 7.2 3 4.4 1 6.8 1.9 301 13 295 165 16.6 0.1 16.8 16.3 08/12/2006 13:40:00 5.8 1.3 8.8 2.6 5.8 1.2 8.8 2.6 5.1 1.2 8.4 2.3 292 11 290 165 16.4 0.1 16.8 16 08/12/2006 13:50:00 4.8 1 7.6 2.3 4.9 1 7.6 3 4.2 1 7.2 2.3 295 11 295 165 16.9 0.3 17.7 16.3 08/12/2006 14:00:00 4.8 0.7 6.8 2.6 4.9 0.7 6.8 3 4.3 0.8 6.5 2.6 295 11 293 165 16.9 0.2 17.4 16.8 08/12/2006 14:10:00 4.3 1.2 7.6 1.9 4.6 1.1 7.6 2.3 3.9 1.1 7.2 1.1 293 16 291 165 17.7 0.1 18.2 17.4 08/12/2006 14:20:00 4.6 1.2 8 1.5 4.8 1.2 8 1.9 4.1 1.2 6.8 1.5 294 17 300 165 17.8 0 18 17.4 08/12/2006 14:30:00 4.4 0.8 6.1 2.3 4.5 0.8 6.1 2.3 3.8 0.8 6.1 1.9 310 12 310 165 18.1 0.1 18.5 17.7 08/12/2006 14:40:00 4.2 1 7.2 2.3 4.4 1 7.2 2.6 3.6 0.9 6.5 1.1 298 15 320 165 18 0 18.5 17.7 08/12/2006 14:50:00 4.4 1 6.8 1.5 4.7 1 7.2 1.9 3.7 0.9 5.7 1.5 311 12 297 165 18.7 0.3 19.4 18.2 08/12/2006 15:00:00 5.1 0.8 7.2 3.4 5.3 0.8 7.2 3.4 4.5 0.8 6.8 1.9 311 9 302 165 18.1 0 18.5 17.7 08/12/2006 15:10:00 5.5 0.8 7.2 3.4 5.6 0.8 7.2 3.4 4.7 1 7.2 1.9 308 8 308 165 17.5 0.2 18 17.1 08/12/2006 15:20:00 5.8 0.8 8.8 3.4 6 0.8 8.4 3.8 4.8 1 7.6 2.6 306 8 298 165 17.2 0 17.4 16.8 08/12/2006 15:30:00 6.4 0.9 8.8 3.8 6.5 0.8 8.8 4.2 5.5 1 8.4 3 303 7 305 165 17 0 17.4 16.6 08/12/2006 15:40:00 6.2 0.8 8 2.6 6.3 0.8 8.4 3 5.1 1 8.4 3 296 6 304 165 16.5 0.1 17.1 16.3 08/12/2006 15:50:00 6.9 1 9.1 3.8 6.9 1 9.1 4.6 6.4 1.1 9.1 3.4 288 8 290 165 16.3 0 16.6 16.3 08/12/2006 16:00:00 7.7 0.7 9.5 4.9 7.7 0.8 9.9 4.6 6.7 1.1 9.5 4.2 291 6 290 165 16.1 0 16.6 16 08/12/2006 16:10:00 7.6 1.1 10.3 4.9 7.6 1.2 11.1 4.6 6.6 1.2 10.3 3.4 294 8 291 165 16.3 0 16.6 16.3 08/12/2006 16:20:00 8.4 1 10.7 5.3 8.3 1.1 11.1 5.3 7.5 1.4 10.3 4.6 291 7 280 165 16.1 0 16.6 15.7 08/12/2006 16:30:00 8.8 0.9 11.1 6.5 8.6 1 11.1 6.1 7.5 1.2 10.3 4.6 306 7 309 165 16.1 0 16.3 16 08/12/2006 16:40:00 10.4 0.7 12.2 8.4 10.3 0.7 11.8 8 7.7 1 11.8 5.7 303 5 299 165 15.7 0 16.3 15.5 08/12/2006 16:50:00 9.1 0.9 11.1 6.5 9.1 0.9 11.5 6.1 7 0.8 9.1 4.9 303 5 302 165 15.3 0 15.7 15.2 08/12/2006 17:00:00 9.6 0.9 11.5 7.2 9.6 1 11.8 7.2 7.1 0.9 9.5 5.3 300 5 307 165 15.2 0 15.5 15.2 08/12/2006 17:10:00 9.6 0.9 11.8 7.2 9.6 1 11.5 7.2 7.3 0.9 9.5 5.3 301 5 305 165 15.1 0 15.2 15.2 08/12/2006 17:20:00 8.7 0.6 10.3 6.8 8.6 0.7 10.3 6.5 7 1 9.9 4.6 295 5 296 165 15.2 0 15.2 15.2 08/12/2006 17:30:00 8.1 0.7 10.3 5.7 8.1 0.7 9.9 6.1 6.8 1 9.5 4.2 296 8 305 165 15.2 0 15.5 15.2 08/12/2006 17:40:00 7.6 0.7 9.1 5.3 7.5 0.8 9.1 4.9 6.1 0.9 8.8 3.8 299 6 305 165 15.2 0 15.5 15.2 08/12/2006 17:50:00 7.7 0.8 10.3 5.7 7.6 0.8 9.5 5.7 6.1 0.9 9.1 4.2 299 6 304 165 15.2 0 15.5 15.2 08/12/2006 18:00:00 7.1 0.7 8.8 4.9 7 0.7 8.8 4.9 6 0.8 8.4 4.2 305 5 301 165 15.2 0 15.5 15.2 08/12/2006 18:10:00 6.4 0.7 8.4 4.2 6.2 0.6 8 4.2 5.4 0.7 7.2 3.8 306 5 307 165 15.5 0 15.7 15.2 08/12/2006 18:20:00 5.7 1 7.6 3.4 5.8 0.9 8 3.8 5 0.8 7.6 3 307 7 304 165 15.5 0 15.7 15.5 08/12/2006 18:30:00 5.1 0.8 7.2 3 5.2 0.8 7.6 3.4 4.7 0.8 7.2 2.6 308 9 308 165 16.1 0.4 16.8 15.7 08/12/2006 18:40:00 6.2 0.9 7.6 4.2 6.2 0.8 7.6 4.2 5.3 0.8 8 3 306 5 306 165 16.3 0.2 16.8 16 08/12/2006 18:50:00 4.6 1 6.8 2.6 4.7 1 6.8 2.6 4.1 1.1 6.8 1.5 307 8 313 165 16 0.2 16.6 15.7 08/12/2006 19:00:00 3.5 0.8 5.3 1.9 3.6 0.8 5.7 1.9 2.9 1 5.7 0.4 301 11 292 165 15.3 0.1 15.7 15.2 08/12/2006 19:10:00 3.4 0.7 5.3 1.9 3.6 0.6 4.9 1.9 2.9 0.7 4.6 1.1 305 9 304 165 15 0 15.2 14.9 08/12/2006 19:20:00 3.7 0.9 6.1 1.1 3.9 0.8 6.1 1.5 2.8 0.8 4.9 0.4 293 11 281 165 14.8 0 15.2 14.9 08/12/2006 19:30:00 4.2 0.7 5.7 1.9 4.3 0.6 5.7 1.5 3.3 0.9 5.3 0.4 291 9 295 165 14.9 0 15.2 14.9 08/12/2006 19:40:00 5 0.8 6.8 3 5.1 0.8 6.8 3 4 0.7 6.1 2.3 295 6 302 165 15.1 0 15.2 14.9 08/12/2006 19:50:00 6.2 0.9 8 3.8 6.2 0.8 8 3.8 4.7 0.7 6.5 3 299 5 298 165 15.5 0 15.7 15.2 08/12/2006 20:00:00 7.2 0.4 8.4 6.1 7.1 0.5 8.4 6.1 5.5 0.6 8.4 4.2 296 3 298 165 15.2 0.2 15.7 14.9 08/12/2006 20:10:00 7.1 0.5 8.4 5.3 7 0.6 8.4 5.3 5.5 0.8 8 3.8 297 5 301 165 14.7 0 15.2 14.6 08/12/2006 20:20:00 7.2 0.6 8.4 5.7 7.1 0.6 8.4 5.3 5.5 0.7 8 3.8 295 4 293 165 14.4 0 14.9 13.8 08/12/2006 20:30:00 7.2 0.6 9.1 5.7 7.1 0.6 9.1 5.7 6.9 0.7 9.1 4.6 287 5 287 165 14.6 0.1 14.6 14.1 08/12/2006 20:40:00 5.9 1 8.8 4.2 6 0.9 8.8 4.6 5.2 1 8.4 3.4 291 5 296 165 14.4 0.1 14.6 13.8 08/12/2006 20:50:00 6 0.5 7.2 4.6 6.1 0.5 7.2 4.9 4.5 0.5 6.1 3.4 297 4 301 165 14.1 0.1 14.6 13.3 08/12/2006 21:00:00 5.9 0.5 7.2 4.2 6.1 0.5 7.2 4.6 4.8 0.6 7.2 3 294 6 295 165 14 0 14.1 13.5 08/12/2006 21:10:00 5.6 0.5 7.2 4.6 5.7 0.5 7.2 4.6 4.3 0.7 6.5 3 296 5 297 165 13.8 0 14.1 13.5 08/12/2006 21:20:00 4.9 0.4 5.7 3.8 5.1 0.4 6.5 3.8 4 0.6 5.7 2.6 293 4 294 165 13.7 0 13.8 13.5 08/12/2006 21:30:00 5.4 0.7 6.8 4.2 5.6 0.7 6.8 4.6 4.6 0.9 6.8 3 292 3 287 165 13.9 0 14.1 13.8 08/12/2006 21:40:00 5.6 0.4 6.8 4.6 5.8 0.4 7.2 4.6 4.5 0.8 6.8 3 294 4 291 165 13.7 0 13.8 13.5 08/12/2006 21:50:00 4.9 0.4 5.7 3.8 5.1 0.4 6.1 3.8 3.7 0.4 4.9 2.6 297 3 301 165 13.7 0 13.8 13.5 08/12/2006 22:00:00 4.6 0.3 5.3 3.8 4.7 0.3 5.3 3.8 3.5 0.4 4.6 2.6 299 3 296 165 13.6 0.1 13.8 13.5 08/12/2006 22:10:00 5 0.5 6.1 3.8 5.1 0.5 6.1 3.8 3.9 0.5 5.3 2.6 303 6 302 165 13.5 0 13.5 13.3 08/12/2006 22:20:00 4.7 0.8 6.5 1.9 4.7 0.7 6.5 2.6 4 0.7 5.7 1.9 294 9 301 165 13.4 0 13.5 13.3 08/12/2006 22:30:00 4.7 0.7 6.5 3 4.7 0.7 6.5 3 3.8 0.6 5.7 2.3 294 6 297 165 13.3 0 13.5 13 08/12/2006 22:40:00 5.4 0.6 7.2 3.8 5.4 0.6 7.2 4.2 4.1 0.5 5.3 3 301 5 294 165 13.1 0 13.3 12.7 08/12/2006 22:50:00 6.2 0.4 6.8 4.9 6.3 0.4 7.2 4.6 4.7 0.6 6.5 3.4 296 3 296 165 13.3 0 13.5 12.7 08/12/2006 23:00:00 3.9 1 5.7 1.5 4.1 0.8 6.1 1.9 3.8 0.6 5.7 2.3 282 9 294 165 13.1 0.2 13.5 12.5 08/12/2006 23:10:00 3.4 0.5 4.6 2.3 3.5 0.5 4.6 1.9 3.2 0.5 4.2 2.3 289 7 289 165 12.8 0.2 13 12.5 08/12/2006 23:20:00 2.9 0.5 3.8 1.5 3.1 0.4 4.2 1.9 3.1 0.4 4.2 1.9 281 7 294 165 12.9 0.2 13.3 12.5 08/12/2006 23:30:00 3.6 0.4 4.6 2.3 3.7 0.4 4.6 2.6 3.7 0.4 4.6 2.6 277 5 281 165 13.3 0.2 13.8 12.7 08/12/2006 23:40:00 3.8 0.4 4.9 2.6 3.9 0.4 4.9 2.6 3.9 0.4 4.9 2.3 280 7 282 165 13.5 0 13.8 13.3 08/12/2006 23:50:00 3.8 0.4 4.6 2.6 3.8 0.4 4.9 2.6 3.3 0.5 4.6 1.9 291 6 281 165 13.5 0.1 13.8 13 08/13/2006 00:00:00 3.9 0.4 4.9 3 3.9 0.4 4.9 2.6 3.1 0.5 4.6 1.9 299 6 304 165 13.4 0.2 13.5 13 08/13/2006 00:10:00 3.8 0.5 5.7 2.6 3.8 0.5 5.3 2.6 3.3 0.5 4.9 1.9 291 6 297 165 13.5 0.2 13.8 13 08/13/2006 00:20:00 4.5 0.6 6.1 3.4 4.4 0.6 6.1 3.4 3.6 0.6 5.3 2.6 296 6 290 165 13.3 0.2 13.8 13 08/13/2006 00:30:00 3.8 0.5 4.9 2.3 3.9 0.5 4.9 2.3 2.9 0.4 4.2 1.9 298 4 297 165 13 0.1 13.3 12.7 08/13/2006 00:40:00 2.5 0.4 3.4 1.5 2.6 0.4 3.4 1.5 2.3 0.3 3.4 1.5 300 4 298 165 12.9 0.1 13.3 12.5 08/13/2006 00:50:00 5.1 0.7 6.5 2.6 5.2 0.7 6.8 2.6 4.7 1.1 6.8 2.3 288 6 284 165 12.8 0.1 13 12.5 08/13/2006 01:00:00 5.6 0.6 7.2 3.8 5.6 0.6 7.2 3.8 4.5 0.6 6.5 3 300 5 298 165 12.7 0 13 12.7 08/13/2006 01:10:00 5.7 0.7 8 4.2 5.7 0.6 7.6 4.2 4.9 0.8 6.8 3 307 8 308 165 12.9 0 13 12.7 08/13/2006 01:20:00 5.3 0.8 7.2 3 5.3 0.8 7.2 3 4.6 0.6 6.5 3 306 9 301 165 12.8 0 13 12.5 08/13/2006 01:30:00 6.5 0.8 8.4 4.6 6.5 0.8 8.4 4.6 5.2 1 7.6 3 296 5 290 165 12.7 0 12.7 12.5 08/13/2006 01:40:00 6.1 0.8 8 3.4 6.1 0.8 8 3.4 4.8 1 8.4 2.6 296 5 289 165 12.5 0 12.7 12.2 08/13/2006 01:50:00 6.3 0.6 8 4.6 6.4 0.6 8 4.6 5.3 0.9 7.2 3.4 293 5 297 165 12.7 0 13 12.5 08/13/2006 02:00:00 6.7 0.6 8.4 5.3 6.7 0.6 8.4 5.3 5.2 0.9 7.6 3.8 296 5 296 165 12.7 0.1 13 12.2 08/13/2006 02:10:00 6.8 0.7 8.8 4.9 6.8 0.7 8.8 4.9 5.6 0.9 9.5 3.8 297 7 284 165 12.7 0 13 12.2 08/13/2006 02:20:00 6.8 1 8.8 4.6 6.6 1 8.8 4.6 5.5 0.9 8.4 3.4 300 7 296 165 12.6 0.1 12.7 12.2 08/13/2006 02:30:00 7.2 0.9 9.1 4.9 7.1 0.9 9.1 4.9 5.7 1 8.8 3.4 298 5 294 165 12.5 0.2 13 11.9 08/13/2006 02:40:00 7.4 1.2 10.3 4.6 7.4 1.2 10.3 4.2 5.8 1.3 10.3 3.4 296 5 292 165 12.3 0 12.5 11.9 08/13/2006 02:50:00 6.7 0.7 8.4 4.9 6.6 0.7 8.4 4.9 5.3 0.8 7.2 3 294 5 294 165 12.4 0 12.7 11.9 08/13/2006 03:00:00 7.5 0.7 8.8 5.7 7.5 0.8 9.1 5.3 7.1 1 9.1 3.8 288 4 285 165 12.3 0 12.5 11.9 08/13/2006 03:10:00 8.1 0.9 10.7 5.7 8.1 0.9 10.3 5.7 6.7 0.9 8.8 4.2 295 5 290 165 12.3 0 12.5 11.9 08/13/2006 03:20:00 6.2 1.2 8.8 3.4 6.1 1.2 8.4 3.8 4.8 0.8 8 3 300 6 293 165 12.3 0 12.5 11.9 08/13/2006 03:30:00 5.9 0.7 7.6 4.2 5.9 0.7 7.6 4.2 4.9 0.8 7.2 3 305 8 310 165 12.2 0 12.5 11.9 08/13/2006 03:40:00 6.9 0.7 8.8 5.3 6.9 0.8 8.8 4.9 5.6 0.9 9.1 3.8 297 6 284 165 12.3 0.1 12.5 11.9 08/13/2006 03:50:00 7.1 0.9 9.1 4.9 6.9 1 9.1 4.6 5.9 1 8.4 3.4 299 8 294 165 12.4 0 12.7 11.9 08/13/2006 04:00:00 6.8 1 9.1 4.6 6.6 1 8.8 4.2 5.4 0.8 7.6 3.4 303 7 300 165 12.3 0 12.5 11.9 08/13/2006 04:10:00 7.1 1.4 9.9 3 7 1.4 9.5 3 5.7 0.8 7.6 3.8 303 9 300 165 12.1 0.2 12.5 11.1 08/13/2006 04:20:00 8.8 0.9 11.1 6.8 8.8 1 11.1 6.5 6.8 1 9.9 4.2 298 5 302 165 11.6 0.1 11.9 10.9 08/13/2006 04:30:00 9.4 0.9 11.5 7.2 9.4 1 11.8 7.2 7.1 0.9 9.9 4.9 302 4 301 165 11.5 0 11.7 11.1 08/13/2006 04:40:00 9.2 0.8 11.5 6.8 9.2 0.9 11.5 6.5 7.4 1 10.3 5.3 303 5 304 165 11.4 0.1 11.7 10.9 08/13/2006 04:50:00 10.9 1.1 13.3 7.2 10.8 1.1 13.3 6.8 9.1 1.2 12.2 4.9 306 6 307 165 11.1 0 11.4 10.9 08/13/2006 05:00:00 10.8 1.2 13.3 7.6 10.7 1.2 13.3 7.6 9.2 1.1 12.6 6.5 309 6 308 165 10.9 0 11.1 10.9 08/13/2006 05:10:00 10.3 0.9 12.6 7.6 10.3 0.9 12.6 7.2 8.5 1.2 12.2 6.1 304 7 308 165 10.9 0 11.1 10.9 08/13/2006 05:20:00 11.8 0.9 14.1 9.5 11.7 0.9 14.1 9.5 8.7 1.2 12.2 5.7 303 5 300 165 10.9 0.1 11.1 10.9 08/13/2006 05:30:00 10.8 1 13.3 7.2 10.8 1 13.3 7.2 8.6 1.1 12.2 6.1 303 6 291 165 10.9 0.1 11.1 10.6 08/13/2006 05:40:00 9.6 1.2 12.6 7.2 9.6 1.2 12.2 7.2 7.6 1 10.7 5.7 304 5 298 165 10.7 0 10.9 10.6 08/13/2006 05:50:00 9.5 0.8 11.8 7.6 9.6 0.9 12.2 8 7.5 1.1 10.3 5.3 298 6 291 165 10.9 0 11.1 10.9 08/13/2006 06:00:00 8.8 0.8 11.5 6.1 8.8 0.8 11.8 6.1 6.7 0.8 9.5 4.9 303 4 305 165 11.1 0 11.4 10.9 08/13/2006 06:10:00 7.9 1 9.9 5.3 7.9 1.1 10.3 5.3 5.9 0.8 7.6 3.8 298 5 295 165 11.1 0 11.4 10.9 08/13/2006 06:20:00 8.2 1.2 11.1 5.3 8.3 1.2 10.7 5.3 6.7 1.1 10.3 4.2 293 5 293 165 11.1 0 11.4 10.9 08/13/2006 06:30:00 9.7 0.7 11.8 8 9.8 0.7 11.5 7.6 7.5 0.9 9.9 5.7 299 5 293 165 11 0 11.4 10.6 08/13/2006 06:40:00 10.3 1.2 13 7.6 10.3 1.2 13 7.2 8.1 0.9 11.1 5.7 305 6 304 165 11 0 11.4 10.6 08/13/2006 06:50:00 10.8 1.2 13 7.2 10.7 1.2 13.3 6.8 8.5 1.1 11.8 5.3 304 6 308 165 11.2 0.1 11.7 10.9 08/13/2006 07:00:00 11.1 1.3 14.1 6.8 11.1 1.3 14.1 6.8 8.5 1 12.6 5.7 301 6 294 165 11.3 0 11.7 10.9 08/13/2006 07:10:00 9.5 1.4 12.6 6.1 9.5 1.4 13 6.1 7.4 1.2 11.1 4.6 300 6 297 165 11.4 0 11.7 11.1 08/13/2006 07:20:00 7.1 1 10.3 4.6 7.2 1 10.3 4.6 5.4 0.9 8 3 295 5 300 165 11.8 0.1 12.2 11.1 08/13/2006 07:30:00 7.8 0.6 9.5 6.1 7.9 0.6 9.5 6.5 6.5 0.9 8.8 4.2 292 4 293 165 12.2 0.2 12.7 11.7 08/13/2006 07:40:00 6.8 0.6 8.4 4.2 6.9 0.6 8.8 4.6 5.7 1 8 3.4 293 6 294 165 12 0.2 12.5 11.7 08/13/2006 07:50:00 7.8 0.9 9.9 5.7 7.9 0.9 9.5 5.7 6.4 1.2 9.5 3.4 294 6 292 165 11.7 0.2 11.9 11.1 08/13/2006 08:00:00 9.4 0.9 10.7 6.5 9.5 1 11.1 6.5 6.9 0.8 9.5 4.9 299 4 304 165 11.9 0.1 12.2 11.4 08/13/2006 08:10:00 8.4 0.9 10.7 6.1 8.5 0.9 10.7 6.1 6.5 1 9.9 4.2 298 6 299 165 12.3 0.2 12.7 11.9 08/13/2006 08:20:00 6.5 0.8 8.8 4.9 6.5 0.7 8.8 4.9 6.2 0.6 8.4 3.8 313 11 307 165 13.2 0 13.5 12.7 08/13/2006 08:30:00 6.5 1.2 9.1 3.4 6.5 1.2 9.1 3.8 5.3 0.9 8.8 3.4 301 9 301 165 13.1 0.1 13.5 12.7 08/13/2006 08:40:00 6.7 0.8 8.8 4.2 6.7 0.9 8.8 4.6 5.4 0.8 8 3.4 301 6 294 165 12.8 0 13 12.7 08/13/2006 08:50:00 8.4 1 10.7 5.7 8.4 1 10.7 4.9 7 0.8 9.1 4.6 307 6 307 165 12.9 0 13 12.5 08/13/2006 09:00:00 7.3 1 9.9 4.6 7.3 1 9.9 4.6 6.6 1.2 9.5 4.2 309 8 307 165 12.8 0.2 13.3 12.5 08/13/2006 09:10:00 7.3 0.8 9.1 5.7 7.2 0.9 9.1 5.3 6.3 1 8.8 4.2 307 6 313 165 13.5 0 13.8 13.3 08/13/2006 09:20:00 6.7 0.9 9.1 4.6 6.7 0.9 9.1 4.6 5.6 1 8.4 3.4 303 9 304 165 13.7 0 13.8 13.5 08/13/2006 09:30:00 7 0.8 9.1 4.9 7 0.8 9.1 4.9 5.8 0.9 8.4 3.4 304 6 296 165 13.9 0.1 14.4 13.5 08/13/2006 09:40:00 6.6 0.7 8.4 4.6 6.5 0.8 8.4 4.6 5.4 0.9 7.6 3 300 6 301 165 14.1 0.1 14.9 13.8 08/13/2006 09:50:00 6 0.8 7.6 3.8 6.1 0.8 8.4 3.8 5.1 0.8 7.2 3 294 8 286 165 14.4 0.2 14.6 14.1 08/13/2006 10:00:00 6 0.7 8 4.2 6.2 0.7 8 4.6 5.2 0.8 8 3.4 292 8 295 165 14.6 0.1 15.5 14.6 08/13/2006 10:10:00 5.6 0.8 7.6 3.4 5.9 0.8 8 3.8 5.1 0.9 7.2 2.6 288 9 310 165 15.2 0.3 16 14.6 08/13/2006 10:20:00 6 1 8.4 3.4 6.2 0.9 8.4 3.8 5.5 1.1 8.4 3 289 8 297 165 15.4 0.2 16 15.2 08/13/2006 10:30:00 6.7 0.7 8 4.6 6.8 0.7 8 4.6 5.4 0.7 7.2 3.4 298 6 294 165 15 0.1 15.7 14.6 08/13/2006 10:40:00 5.8 1 8 3.4 6 1 8 3.8 5 1 7.6 2.6 295 8 298 165 15.2 0 16 15.2 08/13/2006 10:50:00 6 0.5 7.2 4.6 6.3 0.5 7.6 4.9 5.6 0.9 7.6 3 289 8 274 165 15.2 0.1 15.7 14.9 08/13/2006 11:00:00 5.5 0.8 7.6 3.4 5.6 0.8 7.6 3.4 4.8 0.9 8.4 2.6 302 9 301 165 15.2 0.3 16.3 14.6 08/13/2006 11:10:00 5.1 1 7.6 3.4 5.3 1 7.6 3.4 4.9 0.8 6.8 2.6 316 9 308 165 15.9 0.2 16.6 15.5 08/13/2006 11:20:00 6.2 0.9 8.4 3.4 6.4 0.8 8.4 3.8 5.4 1 7.6 3 301 10 295 165 16.1 0.4 16.8 15.5 08/13/2006 11:30:00 5.8 0.7 8 3.8 5.8 0.7 8 3.8 5.2 0.8 7.6 3 309 9 301 165 15.9 0.3 16.3 15.2 08/13/2006 11:40:00 5.6 1 8.4 3.4 5.7 0.9 8.4 3 5 1 8 3 310 11 297 165 16.5 0.2 17.1 16.3 08/13/2006 11:50:00 7.3 0.9 9.1 5.3 7.1 0.9 9.1 4.9 6.3 1.1 9.1 3.8 308 7 315 165 16.5 0 16.8 16.3 08/13/2006 12:00:00 5.1 1.2 9.1 2.6 5.2 1.2 8.8 2.6 4.6 1.3 8.4 2.3 307 9 322 165 16.7 0.4 17.7 16.3 08/13/2006 12:10:00 2.9 1.1 4.9 0.7 3.1 1 4.9 0.4 2.3 0.8 4.6 0.7 293 27 300 165 18.1 0.3 18.5 17.1 08/13/2006 12:20:00 3.9 1 6.1 1.1 4 1 6.5 1.5 2.7 1.1 5.3 0.4 302 15 295 165 17 0.4 17.7 16.3 08/13/2006 12:30:00 3.8 1.1 6.1 0.7 3.9 1 6.5 1.1 2.7 1 4.9 0.4 299 22 308 165 17.5 0.1 17.7 16.8 08/13/2006 12:40:00 2.5 1.2 5.7 0.4 2.6 1.2 5.3 0.4 2 1 4.6 0.4 289 76 240 165 17.6 0.5 18.5 16.8 08/13/2006 12:50:00 1.9 1.3 4.9 0.4 2 1.4 4.9 0.4 1.7 1.2 5.7 0.4 313 98 347 165 16.8 0.7 18.5 16 08/13/2006 13:00:00 1.6 1.2 5.3 0.4 1.7 1 4.2 0.4 1.4 1 4.9 0.4 168 98 358 165 15.7 0.3 16.3 14.9 08/13/2006 13:10:00 2.4 1.2 6.1 0.4 2.5 1.3 5.7 0.4 1.6 0.9 4.6 0.4 308 82 307 165 15.2 0.2 15.7 14.9 08/13/2006 13:20:00 2.1 1.2 6.5 0.4 2.1 1 5.3 0.4 2 1 4.9 0.4 44 86 349 165 15.1 0.3 15.7 14.6 08/13/2006 13:30:00 1.6 1.2 5.3 0.4 1.5 1.2 4.9 0.4 1.3 1 4.6 0.4 196 72 308 165 14.5 0.1 14.9 14.1 08/13/2006 13:40:00 3.3 1.1 5.3 0.4 3.3 1.2 5.3 0.4 2.5 1.1 4.9 0.4 318 58 318 165 15.2 0.1 15.7 14.9 08/13/2006 13:50:00 3.5 1.6 6.8 0.4 3.5 1.7 6.8 0.4 2.6 1.5 6.1 0.4 292 32 308 165 15.3 0 15.7 15.2 08/13/2006 14:00:00 1.2 0.8 3.8 0.4 1.2 0.8 3.8 0.4 1.2 0.6 3 0.4 193 69 351 165 14.8 0 15.5 14.6 08/13/2006 14:10:00 2.3 1.1 4.9 0.4 2.3 1.1 4.9 0.4 1.7 0.8 4.2 0.4 278 69 294 165 14.9 0.2 15.5 14.6 08/13/2006 14:20:00 3.2 1 4.6 0.4 3.3 1 5.7 0.4 2.8 1 4.9 0.4 282 24 291 165 15.3 0 15.7 15.2 08/13/2006 14:30:00 0.9 0.6 3.4 0.4 0.9 0.6 4.2 0.4 0.7 0.4 1.9 0.4 216 45 281 165 14.6 0 15.2 14.4 08/13/2006 14:40:00 1.8 0.7 3.4 0.4 1.7 0.7 3.4 0.4 1.9 0.7 3 0.4 179 11 184 165 14 0.1 14.6 13.8 08/13/2006 14:50:00 1.1 0.6 2.3 0.4 1.1 0.5 2.3 0.4 1.2 0.5 2.3 0.4 154 10 162 165 13.9 0 14.4 13.8 08/13/2006 15:00:00 0.5 0.3 1.9 0.4 0.5 0.3 1.9 0.4 0.7 0.4 2.3 0.4 175 22 165 165 14.4 0.2 14.6 14.1 08/13/2006 15:10:00 1.3 0.5 2.3 0.4 1.3 0.5 2.3 0.4 1.4 0.5 2.3 0.4 179 17 170 165 14.4 0 14.6 14.4 08/13/2006 15:20:00 0.8 0.5 1.9 0.4 0.7 0.5 1.9 0.4 0.7 0.4 1.9 0.4 164 36 154 165 14.6 0.2 15.2 14.4 08/13/2006 15:30:00 1.5 0.6 3.4 0.4 1.5 0.6 3 0.4 1.5 0.7 3 0.4 164 22 155 165 15.1 0.1 15.5 14.9 08/13/2006 15:40:00 0.8 0.6 2.6 0.4 0.7 0.6 2.6 0.4 0.9 0.7 2.6 0.4 143 36 167 165 15.2 0 15.5 14.9 08/13/2006 15:50:00 2.6 0.9 4.2 0.4 2.6 0.9 4.2 0.4 2.1 0.9 3.8 0.4 274 35 285 165 14.9 0 15.2 14.6 08/13/2006 16:00:00 3 0.8 4.9 1.1 3 0.8 5.3 0.7 2.2 0.9 4.9 0.4 344 47 328 165 15 0.1 15.5 14.6 08/13/2006 16:10:00 1 0.5 2.3 0.4 0.9 0.5 1.9 0.4 1.1 0.6 2.3 0.4 111 20 109 165 14.2 0.2 15.2 14.1 08/13/2006 16:20:00 1.2 0.6 2.6 0.4 1.3 0.6 2.6 0.4 1.4 0.5 2.6 0.4 105 7 108 165 14.1 0 14.4 14.1 08/13/2006 16:30:00 0.7 0.5 2.6 0.4 0.7 0.5 3 0.4 0.7 0.4 2.3 0.4 136 69 322 165 14.4 0 14.6 14.4 08/13/2006 16:40:00 1.6 0.9 4.2 0.4 1.6 0.9 3.8 0.4 1.6 0.9 4.2 0.4 9 19 34 165 14.5 0 14.9 14.4 08/13/2006 16:50:00 0.7 0.5 2.3 0.4 0.8 0.5 2.3 0.4 0.8 0.5 2.3 0.4 21 107 36 165 14.6 0 14.9 14.4 08/13/2006 17:00:00 1.1 0.5 2.3 0.4 1.3 0.5 2.3 0.4 1.3 0.4 2.3 0.4 138 21 119 165 13.7 0.2 14.4 13.5 08/13/2006 17:10:00 0.4 0.1 1.1 0.4 0.4 0.1 1.1 0.4 0.5 0.3 1.9 0.4 159 5 162 165 13.5 0 13.5 13.3 08/13/2006 17:20:00 1.6 0.4 2.6 0.4 1.7 0.4 2.6 0.4 1.9 0.4 2.6 0.7 130 9 130 165 13.3 0 13.5 13.3 08/13/2006 17:30:00 1.2 0.3 1.9 0.4 1.3 0.3 1.9 0.4 1.6 0.3 2.3 1.1 144 2 141 165 13.3 0 13.3 13.3 08/13/2006 17:40:00 0.9 0.3 1.5 0.4 1.1 0.3 1.9 0.4 1.3 0.2 1.9 0.7 142 2 145 165 13.3 0 13.3 13.3 08/13/2006 17:50:00 0.4 0 0.4 0.4 0.4 0 0.7 0.4 0.4 0.1 1.1 0.4 138 0 165 165 13.2 0 13.3 13 08/13/2006 18:00:00 0.4 0 0.7 0.4 0.4 0.1 1.1 0.4 0.5 0.2 1.1 0.4 138 0 139 165 13.2 0 13.3 13 08/13/2006 18:10:00 0.4 0 0.4 0.4 0.4 0.1 0.7 0.4 0.4 0.1 1.1 0.4 135 3 165 165 13.3 0 13.5 13 08/13/2006 18:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 127 11 165 165 13.6 0 13.8 13.3 08/13/2006 18:30:00 0.4 0.2 1.5 0.4 0.4 0.2 1.5 0.4 0.4 0.2 1.5 0.4 333 72 313 165 13.9 0 14.1 13.8 08/13/2006 18:40:00 0.5 0.2 1.5 0.4 0.5 0.3 1.5 0.4 0.5 0.3 1.5 0.4 247 22 252 165 14.1 0 14.4 13.8 08/13/2006 18:50:00 0.4 0.1 1.1 0.4 0.4 0.1 1.1 0.4 0.4 0.1 0.7 0.4 141 49 119 165 13.7 0.1 14.1 13.5 08/13/2006 19:00:00 0.6 0.4 1.9 0.4 0.6 0.4 1.9 0.4 0.5 0.3 1.5 0.4 181 49 222 165 13.3 0 13.8 13 08/13/2006 19:10:00 1.2 0.6 2.6 0.4 1.3 0.6 3 0.4 0.9 0.5 2.3 0.4 234 15 231 165 12.9 0 13.3 13 08/13/2006 19:20:00 1.7 0.6 3 0.4 1.8 0.7 3.4 0.7 1.7 0.5 3 0.7 213 35 237 165 12.9 0 13 12.7 08/13/2006 19:30:00 0.5 0.3 1.5 0.4 0.5 0.4 1.5 0.4 0.6 0.4 1.5 0.4 122 56 153 165 12.4 0 12.7 12.5 08/13/2006 19:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.7 0.4 111 17 165 165 12.6 0 12.7 12.5 08/13/2006 19:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.7 0.4 113 1 165 165 12.7 0 12.7 12.2 08/13/2006 20:00:00 0.5 0.2 1.1 0.4 0.4 0.1 1.1 0.4 0.8 0.3 1.1 0.4 147 16 151 165 12.6 0 12.7 12.5 08/13/2006 20:10:00 0.4 0 0.4 0.4 0.4 0 0.7 0.4 0.4 0.1 0.7 0.4 163 17 165 165 12.4 0 12.5 12.2 08/13/2006 20:20:00 0.4 0.2 1.1 0.4 0.5 0.2 1.1 0.4 0.4 0.2 1.1 0.4 254 26 267 165 12.4 0.1 12.5 11.9 08/13/2006 20:30:00 0.5 0.3 1.5 0.4 0.5 0.3 1.5 0.4 0.6 0.4 1.9 0.4 167 5 177 165 12.3 0 12.5 12.2 08/13/2006 20:40:00 0.4 0.2 1.5 0.4 0.4 0.2 1.5 0.4 0.5 0.3 1.5 0.4 165 0 165 165 12.3 0 12.5 11.9 08/13/2006 20:50:00 0.6 0.4 1.5 0.4 0.5 0.2 1.5 0.4 0.7 0.4 1.5 0.4 166 2 165 165 12.3 0 12.5 11.9 08/13/2006 21:00:00 1 0.4 1.9 0.4 0.9 0.5 1.9 0.4 1.3 0.5 1.9 0.4 172 2 175 165 12.4 0 12.7 12.2 08/13/2006 21:10:00 0.8 0.4 1.5 0.4 0.4 0.1 1.5 0.4 1.2 0.3 1.9 0.4 166 2 168 165 12.3 0 12.5 11.9 08/13/2006 21:20:00 1.5 0.2 1.9 1.1 1.5 0.2 1.9 1.1 1.6 0.3 2.3 0.7 165 2 164 165 11.9 0 12.2 11.7 08/13/2006 21:30:00 2.1 0.2 2.6 1.5 2.1 0.2 2.6 1.5 2.2 0.2 2.6 1.5 163 14 164 165 11.8 0.1 12.2 11.7 08/13/2006 21:40:00 1.9 0.3 2.6 1.1 1.8 0.3 2.6 1.1 2 0.3 2.3 1.1 163 7 206 165 11.9 0.1 12.2 11.7 08/13/2006 21:50:00 1.8 0.4 2.3 0.7 1.6 0.4 2.3 0.7 1.8 0.3 2.3 1.1 167 5 164 165 11.8 0.1 12.2 11.7 08/13/2006 22:00:00 1.7 0.2 2.3 1.1 1.6 0.2 2.3 1.1 2 0.2 2.6 1.5 191 9 177 165 11.4 0 11.7 11.4 08/13/2006 22:10:00 1.5 0.3 2.3 0.7 1.3 0.3 2.3 0.7 1.7 0.4 2.6 0.7 191 9 189 165 11.5 0 11.7 11.4 08/13/2006 22:20:00 2.2 0.2 2.6 1.5 2.1 0.2 2.6 1.5 2.4 0.3 2.6 1.9 201 3 204 165 11.5 0 11.7 11.1 08/13/2006 22:30:00 1.9 0.3 2.3 1.1 1.8 0.4 2.3 1.1 2.2 0.3 2.6 1.5 179 14 196 165 11.1 0.1 11.4 10.6 08/13/2006 22:40:00 2 0.3 3 1.5 1.8 0.4 2.6 1.1 2.1 0.3 3 1.5 187 6 184 165 11 0.2 11.4 10.6 08/13/2006 22:50:00 2.7 0.2 3 2.3 2.6 0.2 3 2.3 2.8 0.2 3 2.6 171 7 185 165 11.3 0.2 11.7 10.9 08/13/2006 23:00:00 2.1 0.4 3 1.1 1.9 0.5 2.6 1.1 2.3 0.4 3 1.5 168 4 168 165 11.7 0.1 11.9 11.1 08/13/2006 23:10:00 2.2 0.5 3.4 1.5 1.9 0.5 3 1.1 2.5 0.4 3.4 1.9 174 4 165 165 11.7 0.1 11.9 11.1 08/13/2006 23:20:00 2.9 0.2 3.4 2.3 2.7 0.2 3 2.3 3.1 0.2 3.4 2.6 179 6 165 165 11.5 0.1 11.9 10.9 08/13/2006 23:30:00 2.5 0.4 3.4 1.5 2.2 0.5 3 1.1 2.5 0.5 3.4 1.5 182 5 181 165 11.3 0.1 11.7 10.9 08/13/2006 23:40:00 2.9 0.3 3.4 2.3 2.6 0.3 3.4 2.3 2.7 0.2 3.4 1.9 171 6 177 165 11.1 0.1 11.7 10.9 08/13/2006 23:50:00 2.8 0.2 3.4 1.9 2.5 0.2 3 1.5 2.7 0.2 3 1.9 172 5 179 165 11.1 0 11.4 10.9 08/14/2006 00:00:00 3 0.3 3.8 2.3 2.8 0.3 3.4 2.3 3.1 0.3 3.8 2.3 166 3 164 165 11.5 0 11.7 10.9 08/14/2006 00:10:00 2.3 0.3 3 1.9 2.2 0.3 3 1.5 2.4 0.3 3 1.9 164 8 164 165 11.7 0 11.9 11.1 08/14/2006 00:20:00 2.1 0.6 3 1.5 1.9 0.6 3 1.1 2.3 0.6 3.4 1.5 170 5 163 165 11.6 0 11.9 11.4 08/14/2006 00:30:00 1.5 0.5 2.6 0.7 1.2 0.7 2.6 0.4 1.9 0.4 3 1.1 163 3 159 165 11.6 0 11.7 11.4 08/14/2006 00:40:00 2.5 0.2 3 2.3 2.3 0.2 2.6 1.9 2.8 0.2 3.4 2.3 174 6 170 165 11.6 0 11.9 11.4 08/14/2006 00:50:00 3 0.3 3.8 2.3 2.9 0.3 3.8 2.3 3.2 0.3 3.8 2.6 167 3 166 165 11.4 0.1 11.7 11.1 08/14/2006 01:00:00 3.2 0.4 4.2 2.3 3 0.4 3.8 2.3 3.2 0.4 3.8 2.6 164 3 162 165 11.4 0 11.7 10.9 08/14/2006 01:10:00 2.8 0.5 3.4 1.9 2.6 0.5 3.4 1.5 3 0.4 3.8 1.9 168 4 173 165 11.7 0 11.9 11.4 08/14/2006 01:20:00 2.1 0.4 3 1.5 1.9 0.4 3 1.1 2.2 0.2 3 1.5 164 5 157 165 11.8 0 11.9 11.7 08/14/2006 01:30:00 3 0.3 3.4 2.3 2.9 0.3 3.4 2.3 3 0.3 3.8 2.3 158 2 154 165 11.9 0 11.9 11.7 08/14/2006 01:40:00 3.2 0.2 3.4 2.6 3.1 0.2 3.4 2.6 3.1 0.3 3.8 2.3 161 6 162 165 11.8 0 11.9 11.7 08/14/2006 01:50:00 2.7 0.2 3 2.3 2.7 0.2 3 2.3 2.5 0.2 3 1.9 151 8 158 165 11.7 0 11.9 11.4 08/14/2006 02:00:00 1.8 0.3 2.6 1.1 1.6 0.4 2.6 0.7 2 0.2 2.6 1.5 152 7 140 165 12 0 12.2 11.7 08/14/2006 02:10:00 2.9 0.3 3.4 2.3 2.8 0.3 3.4 1.9 2.9 0.3 3.4 2.3 149 3 147 165 12 0.1 12.2 11.7 08/14/2006 02:20:00 2.7 0.6 3.8 1.5 2.5 0.7 3.8 1.1 2.8 0.6 3.8 1.5 156 11 144 165 11.9 0 11.9 11.7 08/14/2006 02:30:00 3.1 0.6 4.2 1.5 2.9 0.6 4.2 1.1 3.3 0.6 4.2 1.9 160 3 153 165 11.7 0 11.9 11.1 08/14/2006 02:40:00 2.8 0.3 3.4 2.3 2.5 0.4 3.4 1.9 3 0.3 3.8 2.3 168 4 160 165 11.5 0 11.7 11.1 08/14/2006 02:50:00 2.3 0.3 3 1.9 2 0.3 3 1.5 2.4 0.2 3 1.9 168 3 164 165 11.6 0 11.7 11.1 08/14/2006 03:00:00 3.1 0.2 3.4 2.6 2.8 0.2 3.4 2.3 3.2 0.2 3.8 2.6 173 5 168 165 11.5 0 11.9 11.1 08/14/2006 03:10:00 3.1 0.3 3.8 2.3 2.8 0.3 3.8 2.3 3.1 0.3 3.8 2.6 172 5 172 165 11.3 0.1 11.7 10.9 08/14/2006 03:20:00 2.6 0.3 3.4 1.9 2.4 0.4 3.4 1.5 2.5 0.3 3.4 1.9 174 6 171 165 11.4 0 11.7 10.9 08/14/2006 03:30:00 2.1 0.4 3 1.1 1.8 0.5 2.6 0.7 2.2 0.3 3 1.5 179 5 179 165 11.6 0 11.7 10.9 08/14/2006 03:40:00 2.6 0.2 3 2.3 2.4 0.2 3 2.3 2.9 0.2 3.4 2.3 175 4 179 165 11.6 0 11.9 10.9 08/14/2006 03:50:00 3 0.3 3.4 2.3 2.8 0.3 3.4 1.9 2.8 0.2 3.4 2.3 182 4 184 165 11.7 0 11.9 11.1 08/14/2006 04:00:00 3 0.5 3.8 2.3 2.8 0.5 3.8 1.9 2.9 0.3 3.4 2.3 183 3 184 165 11.6 0 11.9 11.1 08/14/2006 04:10:00 2 0.3 2.6 1.1 1.8 0.3 2.6 1.1 2.1 0.3 3 1.5 176 11 191 165 11.6 0.2 11.9 10.9 08/14/2006 04:20:00 3.4 0.5 4.2 2.3 3.2 0.5 4.2 2.3 3.3 0.6 4.2 1.9 175 5 178 165 11.5 0.1 11.9 11.1 08/14/2006 04:30:00 3.9 0.4 4.6 2.6 3.6 0.5 4.6 2.6 3.8 0.5 4.6 2.6 171 4 179 165 11.9 0.1 12.2 11.4 08/14/2006 04:40:00 3 0.4 3.8 2.3 2.7 0.4 3.8 1.9 2.9 0.3 3.8 2.3 176 4 179 165 11.7 0 11.9 11.4 08/14/2006 04:50:00 3.8 0.3 4.6 3 3.5 0.2 4.2 2.6 3.7 0.3 4.6 3 170 4 173 165 11.8 0.1 11.9 11.4 08/14/2006 05:00:00 3.3 0.3 4.2 2.6 3 0.3 4.2 2.3 3.2 0.2 3.8 2.3 173 5 180 165 12 0 12.2 11.7 08/14/2006 05:10:00 2.3 0.4 3.4 1.5 2 0.5 3.4 1.1 2.3 0.4 3.4 1.5 168 11 177 165 11.9 0.1 12.2 11.7 08/14/2006 05:20:00 1.8 0.6 3 0.4 1.5 0.7 3 0.4 1.8 0.4 2.6 1.1 171 10 181 165 11.8 0 11.9 11.7 08/14/2006 05:30:00 2.2 0.5 3.4 0.7 2 0.6 3 0.4 2.2 0.4 3 1.1 168 5 165 165 11.8 0 11.9 11.7 08/14/2006 05:40:00 2.2 0.9 3.8 0.4 2 1 3.8 0.4 2.3 0.7 3.8 0.4 171 6 170 165 12.1 0 12.5 11.7 08/14/2006 05:50:00 2 0.7 3.4 0.4 1.7 0.8 3.4 0.4 2 0.6 3.4 0.7 165 7 170 165 12.3 0 12.5 11.9 08/14/2006 06:00:00 1.6 0.7 3 0.4 1.2 0.7 3 0.4 1.8 0.5 3 0.7 161 6 153 165 12.4 0 12.5 11.9 08/14/2006 06:10:00 1.3 0.5 2.3 0.4 1 0.5 2.3 0.4 1.5 0.3 2.3 0.7 145 10 162 165 12.5 0.1 13 11.9 08/14/2006 06:20:00 1.1 0.4 1.9 0.4 1 0.4 1.9 0.4 1.4 0.3 2.3 0.7 134 8 138 165 12.8 0.1 13 12.2 08/14/2006 06:30:00 0.6 0.3 1.5 0.4 0.6 0.3 1.5 0.4 1 0.5 1.9 0.4 145 15 130 165 12.6 0 12.7 12.2 08/14/2006 06:40:00 0.4 0.1 0.7 0.4 0.4 0 0.4 0.4 0.5 0.2 1.1 0.4 159 14 140 165 13.3 0.3 13.8 12.7 08/14/2006 06:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0.1 1.1 0.4 140 2 165 165 13.9 0 14.1 13.3 08/14/2006 07:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 141 0 165 165 13.5 0.1 13.8 13 08/14/2006 07:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 141 1 165 165 13.5 0 13.8 13.3 08/14/2006 07:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 142 1 165 165 13.3 0 13.5 13 08/14/2006 07:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 141 1 165 165 13.7 0 13.8 13 08/14/2006 07:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.7 0.4 1.5 0.4 141 2 165 165 13.8 0.2 14.1 13.3 08/14/2006 07:50:00 0.7 0.3 1.1 0.4 0.5 0.3 1.1 0.4 0.9 0.3 1.5 0.4 138 3 143 165 13 0.1 13.3 13 08/14/2006 08:00:00 0.4 0.1 1.1 0.4 0.4 0 0.7 0.4 0.7 0.3 1.5 0.4 113 19 136 165 13 0 13.3 13 08/14/2006 08:10:00 0.6 0.3 1.5 0.4 0.4 0.1 1.1 0.4 1.2 0.3 2.3 0.4 134 8 129 165 12.7 0.2 13 12.5 08/14/2006 08:20:00 0.4 0.2 1.1 0.4 0.4 0 0.4 0.4 1.2 0.3 1.9 0.4 120 6 121 165 12.1 0 12.5 11.9 08/14/2006 08:30:00 1.5 0.5 2.3 0.4 1.4 0.5 2.3 0.4 1.7 0.3 2.3 0.7 133 11 128 165 11.9 0.2 12.2 11.4 08/14/2006 08:40:00 1.7 0.3 2.3 0.7 1.5 0.3 2.3 0.4 1.8 0.3 2.6 1.1 138 4 138 165 11.3 0 11.7 10.9 08/14/2006 08:50:00 1.5 0.5 2.6 0.7 1.1 0.6 2.3 0.4 1.4 0.3 2.3 0.7 158 15 164 165 11.3 0 11.7 11.1 08/14/2006 09:00:00 2.2 1 4.9 1.1 2.1 1 4.9 0.7 2.1 0.9 4.9 0.7 216 14 210 165 11.9 0 12.2 11.1 08/14/2006 09:10:00 4.1 0.6 5.3 2.6 4.1 0.6 5.7 2.6 4.2 0.6 5.7 3 198 9 217 165 12.1 0 12.2 11.9 08/14/2006 09:20:00 2.7 0.6 3.8 0.7 2.6 0.7 4.2 0.4 3.1 0.6 4.6 1.5 196 9 192 165 12 0 12.2 11.9 08/14/2006 09:30:00 2.4 0.4 3.4 1.5 2.2 0.4 3.4 1.1 2.4 0.4 3.4 1.5 188 9 187 165 12 0 12.2 11.9 08/14/2006 09:40:00 3 0.6 4.2 1.5 2.9 0.6 3.8 1.1 3 0.7 3.8 1.1 186 8 182 165 12.3 0.1 12.5 11.7 08/14/2006 09:50:00 2.9 0.6 4.9 1.5 2.8 0.6 4.9 1.1 3 0.5 4.2 1.5 185 9 194 165 12.3 0 12.5 11.9 08/14/2006 10:00:00 2.3 0.6 3.8 0.4 2.4 0.6 3.8 1.1 2.5 0.5 3.8 1.5 227 24 222 165 12.4 0.1 12.7 11.9 08/14/2006 10:10:00 1.3 0.6 3 0.4 1.4 0.7 3 0.4 1.5 0.5 3 0.4 240 33 284 165 13.1 0 13.3 12.5 08/14/2006 10:20:00 3 0.8 4.6 1.1 3.1 0.8 4.6 1.1 3.2 0.7 4.6 1.9 214 17 231 165 12.8 0 13.3 12.5 08/14/2006 10:30:00 3.1 0.8 4.6 1.1 3.5 0.5 4.6 1.5 3.5 0.6 4.6 1.5 252 13 239 165 12.7 0.1 13 12.2 08/14/2006 10:40:00 1.6 0.5 2.6 0.4 1.8 0.6 3 0.4 2.1 0.5 3 1.1 225 22 208 165 13 0 13.3 12.7 08/14/2006 10:50:00 2.7 0.6 3.4 0.7 2.6 0.6 3.4 0.4 3 0.5 3.8 1.5 194 12 203 165 12.8 0 13 12.2 08/14/2006 11:00:00 3.4 0.4 4.2 2.3 3.2 0.4 3.8 2.3 3.6 0.4 4.6 2.3 175 12 185 165 12.2 0.1 12.7 11.9 08/14/2006 11:10:00 4.1 0.5 5.3 2.6 4 0.5 5.3 2.6 4.1 0.5 5.3 2.6 200 12 197 165 12 0 12.2 11.9 08/14/2006 11:20:00 4.3 0.7 6.5 2.6 4.2 0.7 6.1 2.3 4 0.6 5.7 2.6 199 11 190 165 12.3 0.1 12.5 12.2 08/14/2006 11:30:00 4.7 0.9 6.8 3 4.6 0.8 6.5 3 4.6 0.8 6.5 2.3 179 9 178 165 12.3 0 12.5 11.9 08/14/2006 11:40:00 6.3 0.6 7.6 4.9 6.1 0.6 7.2 4.6 6.3 0.7 8 4.9 180 6 185 165 11.9 0 12.2 11.7 08/14/2006 11:50:00 6.7 0.6 8.4 4.9 6.4 0.6 8 4.6 6.9 0.6 8.4 5.3 171 6 176 165 11.5 0.2 11.9 10.9 08/14/2006 12:00:00 7.3 0.7 9.1 5.7 7 0.7 8.8 5.3 7.5 0.7 9.5 5.7 173 6 169 165 11 0.1 11.4 10.6 08/14/2006 12:10:00 7 0.6 9.1 5.3 6.7 0.6 8.8 5.3 7.2 0.5 8.8 5.7 177 7 187 165 11 0.1 11.4 10.6 08/14/2006 12:20:00 8.1 0.7 9.9 6.5 8 0.7 9.5 6.1 8.2 0.7 10.3 6.1 183 6 192 165 11.1 0.1 11.4 10.6 08/14/2006 12:30:00 8.3 0.6 9.9 6.8 8 0.5 9.5 6.8 8.4 0.5 9.9 7.2 172 4 174 165 11 0.1 11.4 10.3 08/14/2006 12:40:00 7.8 0.6 9.1 6.1 7.4 0.6 8.8 6.1 7.9 0.6 9.5 6.5 172 5 172 165 10.9 0 11.1 10.6 08/14/2006 12:50:00 7.4 1 10.7 5.3 7.2 0.9 10.3 5.3 7.5 0.8 11.5 5.3 170 9 167 165 10.9 0 11.1 10.6 08/14/2006 13:00:00 9.3 1.2 11.8 6.1 9.3 1.3 11.8 5.7 9.2 1.1 13 6.8 191 9 197 165 10.9 0 11.1 10.6 08/14/2006 13:10:00 9.5 1.3 11.8 6.5 9.6 1.2 11.8 6.5 9.6 1.3 12.2 6.1 195 5 195 165 10.8 0 11.1 10.6 08/14/2006 13:20:00 6.4 0.8 8.8 4.6 6.3 0.8 9.1 4.6 6.7 0.7 9.1 4.9 183 8 199 165 10.7 0 10.9 10.3 08/14/2006 13:30:00 6.1 0.6 7.6 4.9 6 0.6 7.2 4.9 6.4 0.6 8 5.3 180 8 178 165 10.7 0 10.9 10.3 08/14/2006 13:40:00 5.9 1 8 3.4 5.7 0.8 8 3.8 6.1 0.9 8.4 3.8 176 7 165 165 10.8 0 11.1 10.3 08/14/2006 13:50:00 6.5 0.8 8.4 4.9 6.3 0.7 8 4.9 6.7 0.7 8.4 4.9 174 9 177 165 10.8 0 11.1 10.3 08/14/2006 14:00:00 7.5 0.8 9.1 5.3 7.2 0.8 9.1 5.3 7.5 0.8 9.5 5.3 171 6 173 165 10.7 0.1 11.1 10.3 08/14/2006 14:10:00 7.7 0.6 8.8 6.1 7.4 0.5 8.4 6.1 7.8 0.5 9.1 6.5 168 5 165 165 10.7 0.1 10.9 10.3 08/14/2006 14:20:00 8.1 0.5 9.5 6.8 7.8 0.5 9.1 6.5 8.1 0.6 9.5 6.8 166 6 165 165 10.7 0.1 10.9 10.3 08/14/2006 14:30:00 8.4 0.5 9.5 7.2 8.2 0.4 9.1 7.2 8.5 0.6 10.3 6.8 166 13 165 165 10.8 0 11.1 10.6 08/14/2006 14:40:00 9.6 1.2 12.6 6.8 9.4 1.1 12.2 7.2 9.7 1.2 13 6.8 167 5 165 165 10.9 0 11.1 10.3 08/14/2006 14:50:00 11.6 1.1 13.7 8 11.5 1.1 13.7 8.4 11.7 1.2 14.1 8.4 167 13 165 165 10.8 0 11.1 10.3 08/14/2006 15:00:00 11.2 0.8 13.3 8.8 11 0.7 13 9.1 11 0.9 13 8.8 166 8 169 165 10.7 0.1 10.9 10.1 08/14/2006 15:10:00 10.6 0.8 12.2 7.6 10.3 0.8 12.2 7.6 10.6 0.9 12.2 7.6 167 8 165 165 10.7 0.1 10.9 9.8 08/14/2006 15:20:00 11.1 1 13 8.4 10.8 0.9 12.6 8 10.8 1 13 8.4 167 9 166 165 10.7 0.1 10.9 10.1 08/14/2006 15:30:00 10.5 0.9 12.6 8.4 10.2 0.8 12.6 8.4 10.4 0.9 12.6 8 169 7 166 165 10.7 0.2 10.9 10.1 08/14/2006 15:40:00 9.3 0.8 11.1 7.2 9 0.7 10.7 7.2 9.1 0.9 11.1 7.2 171 4 165 165 10.7 0.2 10.9 10.1 08/14/2006 15:50:00 8.6 0.8 9.9 6.1 8.3 0.7 9.9 6.1 8.6 0.9 10.7 6.1 172 4 172 165 10.7 0.2 10.9 10.1 08/14/2006 16:00:00 8.6 0.6 10.3 6.8 8.4 0.6 9.9 6.8 8.8 0.7 10.7 6.8 169 4 168 165 10.7 0.1 10.9 10.1 08/14/2006 16:10:00 9.7 0.7 11.1 7.6 9.4 0.6 10.7 7.6 9.7 0.6 11.5 8 169 4 166 165 10.7 0.1 10.9 10.1 08/14/2006 16:20:00 8.5 0.7 10.3 6.5 8.2 0.7 9.9 6.1 8.5 0.8 11.1 6.1 169 5 170 165 10.7 0.1 10.9 10.3 08/14/2006 16:30:00 7.6 0.8 10.3 6.1 7.4 0.8 9.9 6.1 7.8 0.8 10.3 5.7 169 4 166 165 10.7 0.1 11.1 10.3 08/14/2006 16:40:00 6.6 0.5 7.6 4.9 6.5 0.5 7.6 4.9 6.8 0.6 8.4 5.3 166 6 162 165 10.8 0 11.1 10.3 08/14/2006 16:50:00 6.8 0.5 8 5.7 6.6 0.5 7.6 5.3 6.9 0.6 8 5.7 161 12 165 165 10.9 0 11.1 10.3 08/14/2006 17:00:00 7.4 0.6 8.8 5.7 7.2 0.5 8.4 5.7 7.8 0.6 9.9 6.5 161 8 164 165 10.8 0 11.1 10.3 08/14/2006 17:10:00 6.4 0.7 8 4.9 6.2 0.6 8 4.6 6.6 0.6 8.4 4.6 163 11 163 165 10.9 0 11.1 10.6 08/14/2006 17:20:00 6.6 0.8 8.4 4.6 6.4 0.8 8.4 4.2 7 0.8 8.8 4.6 157 14 151 165 10.9 0 11.1 10.6 08/14/2006 17:30:00 7.1 0.5 8.4 5.3 6.9 0.5 8 5.3 7.2 0.6 9.9 5.7 160 14 164 165 10.9 0 11.1 10.6 08/14/2006 17:40:00 7.7 0.8 9.5 5.3 7.4 0.7 9.5 5.3 7.8 0.6 9.5 5.7 161 11 161 165 10.9 0 11.4 10.6 08/14/2006 17:50:00 9.4 1 11.1 6.1 9.1 1 11.1 6.5 9.3 1.1 11.5 6.5 164 9 165 165 11 0 11.1 10.6 08/14/2006 18:00:00 9.5 0.7 10.7 7.2 9.1 0.6 10.3 6.8 9.4 0.7 11.1 7.2 167 7 164 165 11 0 11.1 10.9 08/14/2006 18:10:00 10.2 0.5 11.5 8.4 9.8 0.5 11.1 8.4 10.3 0.5 11.5 8.8 169 7 172 165 11 0 11.1 10.6 08/14/2006 18:20:00 9.5 0.5 10.7 8 9.1 0.5 10.3 7.6 9.5 0.6 10.7 7.6 168 6 163 165 11 0 11.1 10.9 08/14/2006 18:30:00 9.5 0.5 10.7 8 9 0.5 9.9 7.6 9.7 0.5 10.7 8.4 169 4 170 165 11 0 11.1 10.9 08/14/2006 18:40:00 8.7 0.5 9.9 6.8 8.3 0.5 9.5 6.5 8.7 0.6 9.9 6.8 172 7 178 165 11.1 0 11.1 10.9 08/14/2006 18:50:00 8.8 0.6 9.9 7.2 8.3 0.5 9.1 6.8 8.9 0.6 10.3 6.8 172 5 176 165 11 0 11.1 10.9 08/14/2006 19:00:00 7.7 0.7 9.5 6.1 7.4 0.7 9.1 5.7 7.7 0.6 9.5 6.1 176 6 182 165 11 0 11.1 10.9 08/14/2006 19:10:00 8.8 0.6 10.3 7.2 8.4 0.5 9.5 6.8 8.8 0.6 10.3 7.2 172 5 174 165 11.1 0 11.1 10.9 08/14/2006 19:20:00 9 0.6 10.7 7.6 8.6 0.6 9.9 7.2 9.1 0.5 10.3 7.6 169 13 165 165 11 0 11.1 10.9 08/14/2006 19:30:00 8.8 0.8 10.3 6.5 8.4 0.7 9.9 6.1 8.9 0.8 10.3 6.5 166 15 171 165 11 0 11.1 10.9 08/14/2006 19:40:00 6.6 0.5 8 5.7 6.3 0.5 7.6 5.3 6.7 0.5 8.4 5.7 168 11 167 165 11 0 11.4 10.9 08/14/2006 19:50:00 7.4 0.8 9.1 5.7 7 0.8 8.8 5.7 7.4 0.9 9.5 5.7 171 5 172 165 11.1 0 11.4 10.9 08/14/2006 20:00:00 8.2 0.5 9.9 6.8 7.8 0.5 9.5 6.8 8.2 0.5 9.9 6.8 171 10 173 165 11.1 0 11.4 10.9 08/14/2006 20:10:00 7.4 0.8 9.1 5.3 7 0.8 8.8 5.3 7.3 0.8 8.8 5.3 173 4 175 165 11.1 0 11.4 10.9 08/14/2006 20:20:00 5.3 0.8 6.8 3.4 5.1 0.8 6.5 3.4 5.3 0.8 6.5 3.8 171 5 174 165 11.1 0 11.4 11.1 08/14/2006 20:30:00 3.7 0.7 6.5 2.3 3.5 0.6 6.1 2.6 4 0.6 6.5 2.6 169 5 165 165 11.1 0 11.4 10.9 08/14/2006 20:40:00 5.4 0.8 6.8 3.8 5.1 0.7 6.5 3.8 5.5 0.6 7.2 4.2 173 8 171 165 11.1 0 11.1 11.1 08/14/2006 20:50:00 5.5 0.8 7.2 3 5.3 0.8 6.8 3 5.5 0.9 7.6 3 175 12 174 165 11.1 0 11.4 10.9 08/14/2006 21:00:00 4.5 0.6 6.1 3 4.3 0.5 5.7 3 4.6 0.5 6.1 3.4 170 12 178 165 11.1 0 11.4 10.6 08/14/2006 21:10:00 3.9 0.7 5.7 3 3.8 0.7 5.7 2.6 4 0.6 6.1 3 167 8 166 165 11.1 0 11.4 10.6 08/14/2006 21:20:00 3.7 0.7 5.7 1.9 3.6 0.7 5.7 1.9 3.9 0.5 5.3 2.3 170 10 179 165 11.2 0 11.4 10.9 08/14/2006 21:30:00 3.9 0.6 5.3 2.3 3.7 0.6 4.9 2.3 4.2 0.6 5.7 2.6 165 9 179 165 11.2 0 11.4 10.9 08/14/2006 21:40:00 3.9 1.2 8.4 2.3 3.8 1.2 8 1.9 3.9 1 7.2 1.9 174 12 201 165 11.2 0 11.4 10.9 08/14/2006 21:50:00 3.1 0.9 5.3 1.1 3 0.8 4.9 1.1 3.3 0.7 5.3 2.3 160 9 170 165 11.2 0 11.4 10.6 08/14/2006 22:00:00 3.6 0.7 4.9 1.5 3.5 0.7 4.6 1.5 4 0.6 4.9 2.3 163 8 179 165 11.2 0 11.4 10.9 08/14/2006 22:10:00 3.7 0.4 4.9 2.6 3.5 0.4 4.6 2.6 3.9 0.4 4.9 2.6 165 6 165 165 11.2 0 11.4 10.6 08/14/2006 22:20:00 4.3 0.6 5.7 2.6 4.2 0.6 5.3 2.3 4.5 0.6 6.1 3.4 161 12 154 165 11.2 0 11.4 10.9 08/14/2006 22:30:00 4.4 0.5 5.3 3 4.2 0.4 5.3 2.6 4.5 0.5 5.3 3.4 159 8 156 165 11.2 0 11.4 10.9 08/14/2006 22:40:00 3.9 0.4 4.9 3 3.8 0.3 4.6 3 4.1 0.4 4.9 3 157 5 162 165 11.2 0 11.7 10.9 08/14/2006 22:50:00 4.2 0.5 5.3 3 4.1 0.4 5.3 3 4.4 0.4 5.7 3 160 6 160 165 11.2 0 11.4 10.9 08/14/2006 23:00:00 4.3 0.4 4.9 3 4.2 0.4 4.9 3 4.5 0.4 5.7 3.4 156 5 158 165 11.2 0 11.4 10.9 08/14/2006 23:10:00 4.8 0.6 6.1 3 4.6 0.5 5.7 3 4.9 0.5 6.1 3.8 159 9 168 165 11.2 0 11.4 11.1 08/14/2006 23:20:00 4.3 0.7 5.7 2.3 4.1 0.7 5.3 1.5 4.4 0.7 6.1 3 167 8 166 165 11.3 0 11.4 11.1 08/14/2006 23:30:00 4.9 0.6 6.5 3.4 4.6 0.6 6.1 3 5 0.6 6.5 3 168 4 172 165 11.2 0 11.4 11.1 08/14/2006 23:40:00 4.3 0.4 5.3 3.4 4.1 0.4 4.9 3 4.5 0.5 5.7 3.4 173 8 179 165 11.2 0 11.4 11.1 08/14/2006 23:50:00 2.9 0.5 4.6 1.9 2.7 0.5 4.2 1.5 3.1 0.5 4.6 2.3 177 8 181 165 11.3 0 11.7 11.1 08/15/2006 00:00:00 2.9 1 4.9 1.1 2.7 1 4.6 0.7 3.1 0.8 4.6 1.5 179 5 178 165 11.3 0 11.4 11.1 08/15/2006 00:10:00 3.9 0.4 4.9 2.6 3.7 0.4 4.6 2.6 4.1 0.3 4.9 3 175 7 186 165 11.3 0 11.7 11.1 08/15/2006 00:20:00 4.6 0.5 5.7 3.4 4.3 0.5 5.3 3 4.6 0.5 5.7 2.6 178 3 178 165 11.3 0 11.7 11.1 08/15/2006 00:30:00 4.6 0.6 6.1 3.4 4.4 0.6 5.3 3 4.8 0.6 6.1 3.4 177 4 176 165 11.3 0 11.7 11.1 08/15/2006 00:40:00 4.4 0.4 5.7 3.4 4.2 0.4 5.3 3 4.5 0.5 5.7 3 166 6 165 165 11.2 0 11.7 11.1 08/15/2006 00:50:00 4.2 0.5 5.7 3.4 4 0.5 5.3 3 4.2 0.5 5.7 3.4 169 5 174 165 11.1 0 11.4 11.1 08/15/2006 01:00:00 4.9 0.6 6.5 3.4 4.6 0.6 6.5 3.4 4.9 0.5 6.1 3.8 168 7 159 165 11.1 0 11.4 11.1 08/15/2006 01:10:00 5.8 0.6 7.2 3.8 5.5 0.6 6.5 3.8 5.7 0.6 7.2 4.2 175 7 177 165 11.2 0 11.4 11.1 08/15/2006 01:20:00 5.9 0.6 8 4.2 5.6 0.6 7.6 3.8 5.8 0.6 7.6 4.6 177 6 167 165 11.2 0 11.4 10.9 08/15/2006 01:30:00 6.8 0.6 8.4 5.7 6.4 0.5 8 5.3 6.7 0.5 8.4 5.7 174 6 176 165 11.2 0.1 11.4 10.6 08/15/2006 01:40:00 7.1 0.7 8.8 4.9 6.9 0.7 8.4 4.9 7.2 0.8 9.5 4.6 184 6 189 165 11.3 0.1 11.7 10.9 08/15/2006 01:50:00 8.1 0.5 9.5 6.8 7.8 0.5 8.8 6.5 8.3 0.6 9.9 6.5 176 6 176 165 11.3 0.1 11.7 10.9 08/15/2006 02:00:00 6.4 0.8 8.4 4.9 6.1 0.7 8 4.9 6.6 0.7 8.4 5.3 169 8 178 165 11.3 0 11.7 10.9 08/15/2006 02:10:00 6.6 0.5 7.6 5.3 6.3 0.5 7.2 5.3 6.7 0.5 8 5.7 159 6 162 165 11.2 0 11.4 10.9 08/15/2006 02:20:00 5.8 0.6 7.2 4.2 5.6 0.6 7.2 4.2 6 0.6 8 4.9 161 6 155 165 11.2 0 11.4 10.9 08/15/2006 02:30:00 4.5 0.6 6.1 3 4.2 0.6 5.7 3 4.6 0.6 6.1 3 173 9 173 165 11.2 0 11.4 10.9 08/15/2006 02:40:00 4.5 0.6 6.8 2.6 4.3 0.6 6.5 2.6 4.5 0.5 5.7 2.6 160 11 167 165 11.2 0 11.4 10.9 08/15/2006 02:50:00 4.7 0.6 6.5 3 4.5 0.6 6.1 1.9 4.8 0.5 6.1 3.4 152 11 159 165 11.2 0 11.4 10.9 08/15/2006 03:00:00 4.3 0.7 5.7 1.5 4.2 0.7 5.7 1.1 4.5 0.6 5.7 3 153 10 145 165 11.2 0 11.4 10.9 08/15/2006 03:10:00 4.5 0.4 5.7 3.4 4.3 0.4 5.7 3.4 4.6 0.4 5.7 3.8 155 7 159 165 11.1 0 11.4 10.9 08/15/2006 03:20:00 4.9 0.4 5.7 3.4 4.7 0.4 5.7 3.4 5.1 0.4 5.7 4.2 159 3 160 165 11.2 0 11.4 10.9 08/15/2006 03:30:00 5.2 0.5 6.5 3.4 5 0.5 6.1 3.4 5.3 0.4 6.5 3.8 158 12 165 165 11.2 0 11.4 10.9 08/15/2006 03:40:00 5.9 0.6 7.2 3.8 5.7 0.6 7.2 3.8 6.1 0.6 7.6 4.2 160 8 162 165 11.2 0 11.4 11.1 08/15/2006 03:50:00 5.5 0.6 7.2 4.2 5.2 0.6 6.8 3.8 5.5 0.5 6.8 4.2 169 9 186 165 11.2 0 11.4 11.1 08/15/2006 04:00:00 6.6 0.8 8.8 4.6 6.4 0.8 8.4 4.6 6.8 0.8 8.8 4.9 173 11 181 165 11.3 0 11.7 11.1 08/15/2006 04:10:00 6.3 0.6 8 4.6 6 0.7 7.6 4.2 6.3 0.7 8.4 3.8 167 15 173 165 11.3 0 11.7 11.1 08/15/2006 04:20:00 5.2 0.8 7.6 3.8 4.9 0.7 7.2 3.4 5.2 0.7 7.2 3.8 170 6 178 165 11.2 0 11.4 11.1 08/15/2006 04:30:00 5.3 0.6 6.8 3.8 5.1 0.6 6.5 3.8 5.3 0.7 7.2 3.8 167 9 166 165 11.2 0 11.4 11.1 08/15/2006 04:40:00 5.3 0.6 6.5 3.8 5 0.6 6.1 3.4 5.2 0.6 6.8 3 169 13 154 165 11.3 0 11.4 11.1 08/15/2006 04:50:00 6.6 1.1 8.8 3 6.3 1 8.4 3 6.5 1 8.4 3.8 173 8 180 165 11.3 0 11.4 11.1 08/15/2006 05:00:00 6.2 0.9 8.4 4.2 6 0.8 7.6 4.2 6.4 0.9 8.4 3.8 182 5 169 165 11.3 0 11.4 11.1 08/15/2006 05:10:00 4.8 0.4 5.7 3.8 4.6 0.4 5.7 3.8 5 0.5 6.1 3.8 181 6 189 165 11.3 0 11.4 11.1 08/15/2006 05:20:00 4.4 0.7 6.1 3 4.2 0.6 5.7 2.6 4.3 0.5 5.7 3 175 8 175 165 11.3 0 11.4 11.1 08/15/2006 05:30:00 4.8 0.6 6.1 2.6 4.6 0.5 6.1 3 4.8 0.6 6.1 2.6 176 7 176 165 11.3 0 11.4 11.1 08/15/2006 05:40:00 4.8 0.5 6.1 3.8 4.5 0.5 5.7 3.4 4.8 0.6 6.1 3.4 179 4 180 165 11.3 0 11.4 11.1 08/15/2006 05:50:00 4.8 0.3 5.3 3.8 4.6 0.3 5.3 3.8 5 0.4 6.1 3.8 182 3 181 165 11.3 0 11.7 11.1 08/15/2006 06:00:00 4.7 0.4 5.3 3.8 4.6 0.3 5.3 3.8 4.8 0.4 5.7 4.2 187 3 184 165 11.3 0 11.7 10.9 08/15/2006 06:10:00 4.6 0.3 5.7 3.4 4.4 0.3 5.3 3.4 4.7 0.4 5.3 3.4 188 4 184 165 11.3 0 11.7 10.9 08/15/2006 06:20:00 5.2 0.4 6.1 3.8 5.2 0.4 6.1 3.8 5.2 0.5 6.5 3.4 198 4 201 165 11.4 0 11.7 10.9 08/15/2006 06:30:00 5.3 0.3 6.1 4.2 5.4 0.2 6.1 4.6 5.7 0.3 6.5 4.6 198 5 199 165 11.5 0 11.9 10.9 08/15/2006 06:40:00 4.9 0.3 5.7 4.2 4.8 0.3 5.7 4.2 5 0.4 6.5 3.8 191 3 187 165 11.5 0 11.7 10.9 08/15/2006 06:50:00 4 0.9 5.3 1.9 3.8 0.9 4.9 1.5 4.1 1 5.3 1.5 181 8 186 165 11.5 0 11.7 10.9 08/15/2006 07:00:00 3 0.6 4.2 1.1 2.8 0.6 3.8 0.7 3 0.5 4.6 1.5 182 10 190 165 11.6 0 11.7 11.1 08/15/2006 07:10:00 3.6 0.5 4.6 1.5 3.5 0.5 4.6 1.5 3.7 0.4 4.6 2.3 195 7 190 165 11.7 0 11.9 11.4 08/15/2006 07:20:00 3.7 0.4 4.9 2.3 3.7 0.4 4.9 2.3 3.8 0.5 4.6 2.3 199 5 204 165 11.8 0.1 11.9 11.4 08/15/2006 07:30:00 2.2 0.7 3.8 0.7 2.1 0.8 3.8 0.4 2.4 0.6 3.8 1.1 200 10 197 165 11.9 0 12.2 11.7 08/15/2006 07:40:00 1.2 0.6 3 0.4 0.9 0.6 2.6 0.4 1.7 0.5 3 0.4 195 12 202 165 12 0 12.2 11.7 08/15/2006 07:50:00 2.1 0.6 3.4 0.4 1.9 0.7 3.4 0.4 2.4 0.7 3.8 0.4 174 12 169 165 12.3 0.2 12.5 11.7 08/15/2006 08:00:00 1.6 0.6 3 0.4 1.3 0.7 2.6 0.4 2.1 0.5 3 0.7 166 14 166 165 12.3 0.1 12.7 11.9 08/15/2006 08:10:00 1.8 0.7 3 0.4 1.5 0.8 3 0.4 2.2 0.5 3 0.7 156 23 187 165 12.2 0.1 12.5 11.7 08/15/2006 08:20:00 0.5 0.4 2.3 0.4 0.4 0.3 1.9 0.4 0.6 0.4 1.9 0.4 209 53 211 165 12.3 0.1 12.7 11.9 08/15/2006 08:30:00 0.7 0.4 1.9 0.4 0.5 0.3 1.9 0.4 1.4 0.4 2.3 0.4 153 20 153 165 12.5 0 12.7 12.5 08/15/2006 08:40:00 1 0.7 3 0.4 0.8 0.6 3.4 0.4 1.2 0.7 3 0.4 207 21 178 165 12.7 0 13 12.5 08/15/2006 08:50:00 1.7 0.8 3.8 0.4 1.6 0.8 3.8 0.4 2.1 0.8 3.8 0.4 196 14 196 165 12.7 0 13 12.5 08/15/2006 09:00:00 1.3 0.7 3 0.4 1.2 0.7 3 0.4 1.8 0.5 3 0.4 194 14 208 165 12.5 0 12.7 12.5 08/15/2006 09:10:00 1.2 0.6 3 0.4 1.1 0.7 3 0.4 1.7 0.6 3 0.4 201 19 197 165 13 0 13.3 12.7 08/15/2006 09:20:00 1.4 0.8 3.4 0.4 1.2 0.8 3.4 0.4 1.9 0.7 3.8 0.4 171 15 160 165 13 0.1 13.3 12.5 08/15/2006 09:30:00 1.6 0.6 3 0.4 1.4 0.6 3 0.4 2 0.6 3.4 0.4 167 17 154 165 13.1 0 13.3 12.7 08/15/2006 09:40:00 2 0.7 3.4 0.4 1.9 0.8 3.8 0.4 2.4 0.7 3.8 0.4 160 13 118 165 12.9 0 13 12.7 08/15/2006 09:50:00 2.4 0.8 4.2 0.4 2.2 0.8 4.2 0.4 2.8 0.7 4.6 0.7 168 11 157 165 13.3 0 13.5 13 08/15/2006 10:00:00 3.3 0.4 4.2 2.3 3.2 0.3 4.2 2.3 3.4 0.4 4.6 2.3 131 11 148 165 13.3 0 13.5 13 08/15/2006 10:10:00 2.9 0.6 4.9 1.1 2.9 0.6 4.6 0.7 3.2 0.5 4.9 1.9 142 12 164 165 13.6 0.2 14.1 13 08/15/2006 10:20:00 3.7 1 5.7 1.9 3.6 1 5.7 1.5 4.1 0.8 6.1 2.6 154 10 166 165 13.4 0.2 14.1 13 08/15/2006 10:30:00 3.7 0.7 5.3 1.9 3.5 0.6 4.9 1.9 4 0.6 5.3 2.3 160 11 164 165 12.8 0 13 12.5 08/15/2006 10:40:00 2.4 0.6 3.8 0.7 2.3 0.7 3.8 0.7 2.9 0.6 4.2 1.9 143 13 164 165 13.2 0 13.5 13 08/15/2006 10:50:00 1.9 0.5 3.4 0.7 1.7 0.6 3.4 0.4 2.4 0.4 3.8 1.5 129 11 119 165 13.5 0 13.5 13.3 08/15/2006 11:00:00 1.8 0.9 3.8 0.4 1.6 0.9 3.4 0.4 2.3 0.6 4.6 0.7 151 23 183 165 13.6 0.2 14.1 13.3 08/15/2006 11:10:00 2.2 0.8 4.6 0.4 2.1 0.9 4.6 0.4 2.7 0.7 4.9 0.7 159 22 180 165 14.4 0.2 14.9 13.8 08/15/2006 11:20:00 2.4 1 4.6 0.4 2.3 1 4.6 0.4 2.8 0.8 4.6 0.4 168 26 178 165 14.6 0 15.5 14.6 08/15/2006 11:30:00 1.9 0.7 3.4 0.4 1.8 0.7 3.8 0.4 2.5 0.5 3.8 1.5 133 18 130 165 14.5 0.1 14.9 14.1 08/15/2006 11:40:00 1.9 0.8 3.8 0.4 1.8 0.9 3.4 0.4 2.3 0.6 3.8 1.1 141 15 129 165 14.5 0 15.2 14.1 08/15/2006 11:50:00 2 0.6 3.8 0.4 1.9 0.6 3.4 0.4 2.5 0.5 3.8 0.7 148 13 153 165 14.6 0.1 15.2 14.4 08/15/2006 12:00:00 1.6 0.6 3.4 0.4 1.5 0.7 3.4 0.4 2.2 0.5 3.4 0.7 175 11 174 165 14.9 0 15.5 14.6 08/15/2006 12:10:00 1.9 1.1 5.3 0.4 1.6 1.1 5.7 0.4 2.1 0.9 5.7 0.4 122 58 80 165 15.7 0.2 16.3 15.2 08/15/2006 12:20:00 1.8 1 4.2 0.4 1.6 1 4.2 0.4 1.9 1 4.6 0.4 71 41 61 165 15.7 0.3 16.3 15.2 08/15/2006 12:30:00 2 0.9 3.8 0.4 1.9 1 3.8 0.4 2.2 0.8 3.8 0.4 60 23 42 165 15 0 15.5 14.6 08/15/2006 12:40:00 1.9 0.8 4.2 0.4 1.9 0.7 3.8 0.4 1.9 0.6 3.4 0.4 72 27 54 165 14.7 0.1 15.5 14.6 08/15/2006 12:50:00 2 0.5 3 0.4 2 0.5 3.4 0.4 2 0.4 3 0.7 59 20 37 165 14.4 0 14.6 14.4 08/15/2006 13:00:00 2.8 0.4 3.8 1.9 2.8 0.4 3.4 1.5 3.1 0.4 3.8 1.9 33 8 22 165 14.4 0 14.6 14.4 08/15/2006 13:10:00 3.1 0.4 4.2 1.9 3 0.4 4.2 1.9 3.3 0.4 4.2 1.9 32 8 31 165 14.5 0 14.6 14.4 08/15/2006 13:20:00 3.1 0.5 4.2 1.9 3 0.6 4.2 1.1 3.3 0.6 4.6 1.9 27 12 19 165 14.4 0 14.6 14.4 08/15/2006 13:30:00 3.2 0.4 4.2 1.9 2.9 0.6 4.2 0.7 3.6 0.4 4.6 2.3 21 11 7 165 14.2 0 14.6 14.1 08/15/2006 13:40:00 2.9 0.4 3.8 1.5 2.6 0.6 3.8 0.4 3.1 0.4 4.2 1.9 20 11 6 165 14.3 0 14.6 14.1 08/15/2006 13:50:00 2.5 0.5 3.4 1.1 2.4 0.5 3.4 0.4 2.8 0.5 3.8 1.1 43 9 39 165 14 0.1 14.6 13.8 08/15/2006 14:00:00 2.4 0.5 3.4 0.7 2.1 0.6 3.4 0.4 2.7 0.5 3.8 1.5 28 13 34 165 13.9 0 14.1 13.8 08/15/2006 14:10:00 2.1 0.5 3 1.1 1.7 0.6 3 0.4 2.4 0.5 3.4 1.1 21 10 15 165 14.1 0 14.4 14.1 08/15/2006 14:20:00 2 0.5 3 0.7 1.6 0.7 3 0.4 2.2 0.5 4.2 1.1 19 10 16 165 14.1 0 14.4 14.1 08/15/2006 14:30:00 1.9 0.4 2.6 0.7 1.5 0.6 3 0.4 2.2 0.4 3 1.1 2 18 12 165 14.2 0 14.4 13.8 08/15/2006 14:40:00 2.5 0.3 3.4 1.5 1.7 0.6 2.6 0.4 2.8 0.3 3.8 1.9 5 11 11 165 13.7 0 14.1 13.5 08/15/2006 14:50:00 2.8 0.3 3.8 1.9 2.5 0.6 3.8 1.1 3.1 0.4 4.2 2.3 14 7 3 165 14 0.3 14.6 13.5 08/15/2006 15:00:00 3.6 0.5 4.6 2.3 3 0.6 4.6 1.5 3.8 0.5 4.9 2.6 10 8 3 165 15.4 0.3 16 14.6 08/15/2006 15:10:00 3 0.4 4.2 1.9 2.6 0.5 3.8 1.5 3.3 0.5 4.6 2.3 13 11 12 165 15.5 0.1 16 15.2 08/15/2006 15:20:00 3.1 0.4 4.2 1.9 2.9 0.4 3.8 1.5 3.5 0.4 4.9 2.3 19 7 9 165 14.8 0.1 15.5 14.6 08/15/2006 15:30:00 3.1 0.4 3.8 2.3 3.1 0.5 3.8 1.1 3.5 0.4 4.2 2.6 22 5 22 165 14.4 0 14.6 14.4 08/15/2006 15:40:00 3.7 0.3 4.6 2.6 3.4 0.5 4.6 1.9 3.9 0.4 4.6 2.6 17 6 22 165 14.4 0 14.6 14.4 08/15/2006 15:50:00 3.4 0.3 4.2 2.6 3.2 0.4 4.6 2.3 3.8 0.4 4.6 2.6 19 5 19 165 14.4 0 14.6 14.4 08/15/2006 16:00:00 3 0.4 4.2 1.9 2.5 0.5 3.8 1.1 3.3 0.4 4.2 2.3 11 6 12 165 14.4 0 14.6 14.4 08/15/2006 16:10:00 3.1 0.4 4.2 2.3 2.5 0.6 4.2 1.1 3.4 0.4 4.2 2.3 8 9 353 165 14.3 0.1 14.6 14.1 08/15/2006 16:20:00 3.8 0.5 4.9 3 2.6 0.8 4.9 1.1 4.1 0.4 4.9 3 357 5 355 165 14 0 14.4 13.8 08/15/2006 16:30:00 3.8 0.3 4.6 3 2.8 0.7 4.9 1.5 4.1 0.3 4.9 3 4 8 346 165 13.7 0 14.1 13.5 08/15/2006 16:40:00 3.8 0.4 5.3 3 2.7 0.9 5.3 1.5 4.1 0.4 5.3 3 358 8 348 165 13.5 0 13.8 13.5 08/15/2006 16:50:00 4.8 0.5 5.7 3.8 4.1 1 5.7 1.5 4.9 0.4 6.1 3.8 351 5 341 165 13.7 0 13.8 13.5 08/15/2006 17:00:00 4.4 0.4 5.3 3.4 4.2 0.6 5.7 2.3 4.5 0.4 5.3 3.4 347 5 353 165 13.8 0 14.1 13.5 08/15/2006 17:10:00 2.7 0.8 4.6 1.1 2.8 0.9 4.6 0.7 2.9 0.7 4.6 1.5 338 8 336 165 13.9 0 14.1 13.8 08/15/2006 17:20:00 0.8 0.5 2.3 0.4 0.6 0.4 2.3 0.4 1 0.6 2.3 0.4 344 17 338 165 13.9 0 14.1 13.8 08/15/2006 17:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0.1 1.1 0.4 58 61 165 165 13.6 0.1 13.8 13.3 08/15/2006 17:40:00 0.4 0.1 0.7 0.4 0.4 0.1 0.7 0.4 0.5 0.3 1.1 0.4 144 8 145 165 13.2 0 13.5 13 08/15/2006 17:50:00 0.4 0.2 1.5 0.4 0.4 0.1 1.1 0.4 0.4 0.2 1.1 0.4 96 69 352 165 13.1 0 13.3 12.7 08/15/2006 18:00:00 0.5 0.2 1.5 0.4 0.5 0.3 1.5 0.4 0.7 0.5 2.3 0.4 300 28 355 165 13.1 0 13.3 12.7 08/15/2006 18:10:00 1.3 0.7 3 0.4 1.4 0.8 3 0.4 1.7 0.7 3.4 0.4 20 19 35 165 12.9 0 13 12.2 08/15/2006 18:20:00 2.8 0.7 4.2 0.7 2.8 0.8 4.2 1.1 3.3 0.6 4.6 1.1 30 13 25 165 12.5 0.1 12.7 12.5 08/15/2006 18:30:00 3.1 0.5 4.2 1.9 3.1 0.5 4.2 1.5 3.7 0.5 4.9 2.3 31 9 25 165 12.3 0 12.5 12.2 08/15/2006 18:40:00 2.5 0.4 3.4 1.5 2.6 0.4 3.4 1.5 3.4 0.4 4.6 2.6 30 5 30 165 12.2 0 12.5 12.2 08/15/2006 18:50:00 1.7 0.4 3 0.7 1.2 0.7 3 0.4 2.6 0.4 3.4 1.5 11 10 31 165 12.3 0 12.5 12.2 08/15/2006 19:00:00 1.7 0.3 2.6 0.7 1.2 0.5 2.3 0.4 2.2 0.3 3 1.5 348 10 7 165 12.2 0 12.5 12.2 08/15/2006 19:10:00 3 0.7 4.9 1.5 2.8 0.9 4.9 0.7 3.7 0.8 5.3 1.9 21 11 32 165 11.9 0.2 12.2 11.7 08/15/2006 19:20:00 4.8 0.5 5.7 3.8 4.8 0.5 5.7 3.4 5.1 0.6 6.1 3.8 33 5 36 165 11.5 0 11.9 11.1 08/15/2006 19:30:00 5.3 0.4 6.1 4.6 5.4 0.4 6.1 4.6 5.5 0.5 6.5 4.2 30 3 26 165 11.3 0.1 11.7 11.1 08/15/2006 19:40:00 5.9 0.3 6.8 4.9 6 0.4 6.8 4.6 6.2 0.4 7.2 5.3 28 3 27 165 11.3 0.1 11.7 10.9 08/15/2006 19:50:00 6.1 0.4 6.8 4.9 6 0.4 6.8 4.9 6 0.5 6.8 4.6 25 3 25 165 11.3 0.1 11.7 10.9 08/15/2006 20:00:00 6.2 0.4 6.8 4.9 6.1 0.5 6.8 4.6 6.1 0.4 7.2 4.9 26 2 24 165 11.2 0.2 11.7 10.9 08/15/2006 20:10:00 6.3 0.3 7.2 5.3 6.3 0.3 7.2 5.3 6.2 0.4 7.2 4.6 31 3 29 165 11.1 0.3 11.4 10.9 08/15/2006 20:20:00 6.2 0.3 6.8 5.3 6.3 0.3 6.8 5.3 6.3 0.3 7.2 5.3 31 3 31 165 11.2 0.2 11.4 10.9 08/15/2006 20:30:00 5.8 0.3 6.5 4.9 5.9 0.3 6.8 4.9 5.8 0.4 6.8 4.6 29 2 29 165 11.3 0 11.4 10.9 08/15/2006 20:40:00 5.8 0.3 6.5 4.9 5.8 0.3 6.5 4.6 5.8 0.4 6.8 4.2 27 3 26 165 11.3 0 11.4 11.1 08/15/2006 20:50:00 6 0.2 6.5 5.3 6.1 0.3 6.8 5.3 6.1 0.4 6.8 4.6 27 2 26 165 11.3 0 11.4 11.1 08/15/2006 21:00:00 5.7 0.3 6.5 4.6 5.6 0.4 6.5 3.8 5.7 0.5 6.5 4.2 26 3 25 165 11.3 0 11.4 11.1 08/15/2006 21:10:00 5 0.4 5.7 3.8 4.9 0.4 5.7 3.8 5.4 0.3 6.1 4.2 21 2 23 165 11.3 0 11.4 11.1 08/15/2006 21:20:00 4 0.2 4.6 3.4 3.9 0.3 4.6 3 4.5 0.2 4.9 3.8 23 3 25 165 11.2 0 11.4 11.1 08/15/2006 21:30:00 3.8 0.2 4.2 3.4 3.7 0.3 4.2 3 4.4 0.2 4.9 3.8 23 1 21 165 11.1 0 11.4 10.6 08/15/2006 21:40:00 3.9 0.3 4.6 3.4 3.8 0.4 4.6 3 4.4 0.3 4.9 3.8 23 2 27 165 11.1 0 11.4 10.6 08/15/2006 21:50:00 3 0.4 4.2 1.9 2.6 0.7 4.2 1.1 3.6 0.4 4.6 2.6 17 5 25 165 11.1 0 11.4 10.6 08/15/2006 22:00:00 2 0.2 2.6 1.5 1.3 0.5 2.3 0.4 2.6 0.3 3.4 2.3 13 2 7 165 11.2 0 11.4 10.6 08/15/2006 22:10:00 1.9 0.2 2.3 1.1 0.8 0.5 2.3 0.4 2.4 0.3 3 1.5 2 6 4 165 11.3 0 11.4 10.9 08/15/2006 22:20:00 1.4 0.3 1.9 0.7 0.8 0.4 1.9 0.4 2.1 0.2 2.6 1.5 8 7 16 165 11.3 0 11.4 10.9 08/15/2006 22:30:00 1.5 0.2 1.9 1.1 1.1 0.4 1.9 0.4 2.1 0.2 2.6 1.5 16 1 15 165 11.3 0 11.4 11.1 08/15/2006 22:40:00 0.7 0.3 1.5 0.4 0.4 0.2 1.1 0.4 1.6 0.3 2.3 1.1 20 0 20 165 11.2 0 11.4 10.9 08/15/2006 22:50:00 0.5 0.2 1.1 0.4 0.4 0 0.4 0.4 0.8 0.4 1.9 0.4 20 0 20 165 11.1 0 11.4 10.9 08/15/2006 23:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.6 0.3 1.5 0.4 100 22 165 165 11.3 0 11.4 10.9 08/15/2006 23:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0.1 0.7 0.4 114 0 165 165 11.3 0 11.4 10.9 08/15/2006 23:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 114 0 165 165 11.3 0.1 11.4 10.9 08/15/2006 23:30:00 0.4 0 0.7 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 125 9 132 165 11.3 0.1 11.4 10.9 08/15/2006 23:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 132 0 165 165 11.1 0 11.4 10.9 08/15/2006 23:50:00 0.5 0.3 1.1 0.4 0.4 0 0.4 0.4 0.9 0.4 1.5 0.4 151 15 162 165 11.1 0 11.1 10.6 08/16/2006 00:00:00 0.8 0.2 1.1 0.4 0.4 0 0.4 0.4 1.3 0.2 1.9 1.1 178 6 169 165 11.1 0 11.4 10.6 08/16/2006 00:10:00 0.5 0.2 1.1 0.4 0.4 0 0.4 0.4 1.2 0.2 1.5 0.4 182 0 182 165 11.1 0 11.4 10.6 08/16/2006 00:20:00 0.4 0.1 0.7 0.4 0.4 0 0.4 0.4 1.1 0.2 1.5 0.4 187 7 182 165 11.1 0 11.4 10.6 08/16/2006 00:30:00 0.5 0.2 1.1 0.4 0.4 0.1 1.1 0.4 1 0.4 1.9 0.4 199 4 203 165 11.1 0.1 11.4 10.6 08/16/2006 00:40:00 1 0.2 1.5 0.7 0.5 0.3 1.5 0.4 1.6 0.2 1.9 1.1 206 4 208 165 11.2 0 11.4 10.6 08/16/2006 00:50:00 1.9 0.4 2.6 1.1 1.8 0.4 2.6 1.1 2.2 0.4 2.6 1.5 202 1 201 165 11.2 0.1 11.4 10.6 08/16/2006 01:00:00 2.1 0.2 2.6 1.5 1.9 0.3 2.6 1.1 2.3 0.2 3 1.9 195 2 200 165 11.2 0.1 11.4 10.6 08/16/2006 01:10:00 2.2 0.2 2.6 1.5 2.1 0.2 2.6 1.5 2.5 0.2 3 1.9 195 1 194 165 11.2 0.2 11.4 10.6 08/16/2006 01:20:00 2.3 0.1 2.6 1.9 2.2 0.2 2.6 1.9 2.6 0.2 3 1.9 199 1 198 165 11.3 0.1 11.4 10.6 08/16/2006 01:30:00 2.4 0.3 3 1.9 2.3 0.3 2.6 1.9 2.7 0.2 3 2.3 189 5 188 165 11.3 0.1 11.4 10.6 08/16/2006 01:40:00 2.8 0.2 3.4 2.3 2.7 0.3 3.4 2.3 3.2 0.2 3.8 2.6 185 1 186 165 11.3 0.1 11.4 10.6 08/16/2006 01:50:00 3.1 0.3 3.8 2.6 3 0.3 3.4 2.3 3.3 0.2 3.8 2.6 188 2 187 165 11.3 0.2 11.4 10.6 08/16/2006 02:00:00 2.5 0.3 3 1.9 2.4 0.3 3 1.9 3 0.3 3.4 2.3 194 1 191 165 11.3 0.1 11.7 10.9 08/16/2006 02:10:00 2.4 0.2 3 1.9 2.2 0.2 2.6 1.9 2.8 0.2 3.4 2.3 188 7 178 165 11.3 0.1 11.7 10.9 08/16/2006 02:20:00 2.8 0.2 3 2.6 2.7 0.1 3 2.3 3.2 0.2 3.4 2.6 180 1 181 165 11.3 0.1 11.4 10.9 08/16/2006 02:30:00 2.7 0.2 3 2.3 2.6 0.2 3 2.3 3.2 0.2 3.4 2.6 180 1 181 165 11.3 0.1 11.4 10.9 08/16/2006 02:40:00 2.1 0.3 2.6 1.5 1.9 0.3 2.6 1.5 2.5 0.3 3 1.9 185 2 182 165 11.3 0.1 11.4 10.9 08/16/2006 02:50:00 2.2 0.2 2.6 1.9 2 0.2 2.6 1.5 2.6 0.2 3 2.3 172 5 178 165 11.3 0.1 11.4 10.9 08/16/2006 03:00:00 2.2 0.2 2.6 1.9 1.9 0.2 2.3 1.5 2.5 0.2 3 2.3 167 10 166 165 11.3 0.1 11.4 10.9 08/16/2006 03:10:00 2.2 0.2 2.6 1.9 2 0.2 2.3 1.5 2.4 0.2 2.6 1.9 164 4 164 165 11.3 0.1 11.4 10.9 08/16/2006 03:20:00 2.2 0.2 2.6 1.5 1.9 0.2 2.3 1.5 2.5 0.2 3 2.3 166 2 162 165 11.3 0.1 11.4 10.9 08/16/2006 03:30:00 2 0.3 2.6 1.1 1.7 0.3 2.3 0.7 2.3 0.3 3 1.9 168 3 162 165 11.3 0 11.4 10.9 08/16/2006 03:40:00 1.6 0.3 2.3 1.1 1.3 0.3 1.9 0.7 1.9 0.2 2.3 1.5 170 4 165 165 11.3 0 11.4 10.9 08/16/2006 03:50:00 1.4 0.3 2.3 0.7 1 0.4 1.9 0.4 1.6 0.3 2.3 1.1 181 1 180 165 11.3 0.1 11.4 10.9 08/16/2006 04:00:00 1.5 0.3 2.3 1.1 1.2 0.4 1.9 0.4 1.6 0.2 1.9 1.1 182 3 186 165 11.3 0 11.7 10.9 08/16/2006 04:10:00 2.3 0.2 2.6 1.9 2 0.2 2.3 1.5 2 0.2 2.6 1.5 182 4 178 165 11.3 0.1 11.7 10.9 08/16/2006 04:20:00 2.6 0.2 3 2.3 2.3 0.2 2.6 1.9 2.4 0.2 2.6 1.9 178 2 179 165 11.3 0 11.4 11.1 08/16/2006 04:30:00 2.5 0.3 3 1.9 2.2 0.3 2.6 1.5 2.4 0.2 3 1.9 175 5 178 165 11.3 0 11.7 11.1 08/16/2006 04:40:00 2.3 0.2 3 1.9 2 0.3 2.6 1.5 2.5 0.2 3 2.3 164 3 163 165 11.1 0 11.4 11.1 08/16/2006 04:50:00 2.4 0.3 3 1.9 2.2 0.3 3 1.9 2.6 0.2 3 2.3 164 1 164 165 11.1 0 11.4 11.1 08/16/2006 05:00:00 2.5 0.2 3 1.9 2.3 0.2 2.6 1.5 2.6 0.2 3 1.9 166 2 164 165 11.1 0 11.4 11.1 08/16/2006 05:10:00 2.1 0.2 2.3 1.5 1.7 0.3 2.3 1.1 2.2 0.3 2.6 1.5 167 4 163 165 11.1 0 11.4 11.1 08/16/2006 05:20:00 1.8 0.2 2.3 1.1 1.4 0.3 1.9 0.7 1.9 0.2 2.3 1.1 179 2 179 165 11.3 0 11.4 11.1 08/16/2006 05:30:00 0.9 0.4 1.5 0.4 0.5 0.2 1.1 0.4 1.4 0.3 1.9 0.7 183 1 183 165 11.3 0 11.7 11.1 08/16/2006 05:40:00 2 0.5 2.6 1.1 1.5 0.8 2.3 0.4 2.3 0.4 3 1.5 174 3 170 165 11.3 0 11.7 11.1 08/16/2006 05:50:00 2.4 0.2 3 1.9 2.1 0.2 2.6 1.5 2.6 0.2 3 1.9 177 2 179 165 11.3 0 11.4 11.1 08/16/2006 06:00:00 1.9 0.3 2.3 1.1 1.7 0.3 2.3 0.7 2 0.3 2.6 1.5 180 6 175 165 11.3 0 11.7 11.1 08/16/2006 06:10:00 1.7 0.4 2.3 1.1 1.5 0.4 1.9 0.7 1.9 0.4 2.6 1.1 179 3 179 165 11.4 0 11.7 11.1 08/16/2006 06:20:00 2 0.2 2.6 1.5 1.7 0.2 2.3 1.1 2.1 0.2 2.6 1.5 179 2 179 165 11.5 0 11.7 11.4 08/16/2006 06:30:00 1.4 0.2 1.9 0.7 1.1 0.2 1.9 0.7 1.8 0.2 2.3 1.5 185 5 177 165 11.6 0 11.9 11.4 08/16/2006 06:40:00 0.9 0.3 1.9 0.4 0.5 0.3 1.9 0.4 1.1 0.4 1.9 0.4 208 16 212 165 11.7 0 11.9 11.1 08/16/2006 06:50:00 1.2 0.2 1.9 0.4 0.8 0.3 1.5 0.4 1.6 0.3 2.3 0.7 183 14 200 165 11.8 0 11.9 11.4 08/16/2006 07:00:00 1.8 0.6 3 0.7 1.5 0.7 2.6 0.4 1.8 0.5 2.6 0.7 187 8 187 165 11.9 0 12.2 11.7 08/16/2006 07:10:00 0.4 0.2 1.1 0.4 0.4 0 0.4 0.4 0.4 0.1 1.1 0.4 179 0 179 165 12 0 12.2 11.7 08/16/2006 07:20:00 1.9 0.4 2.6 0.7 1.5 0.6 2.3 0.4 2 0.5 2.6 0.7 177 1 178 165 12.3 0.1 12.7 11.7 08/16/2006 07:30:00 0.4 0.2 1.1 0.4 0.4 0 0.4 0.4 0.7 0.3 1.5 0.4 166 3 175 165 12.6 0 12.7 12.5 08/16/2006 07:40:00 0.8 0.5 1.9 0.4 0.6 0.4 1.5 0.4 0.8 0.5 1.9 0.4 172 3 177 165 12.8 0.2 13 12.2 08/16/2006 07:50:00 0.4 0 0.7 0.4 0.4 0 0.4 0.4 0.4 0.2 1.1 0.4 180 10 197 165 13.1 0 13.5 12.5 08/16/2006 08:00:00 0.4 0.2 1.5 0.4 0.4 0.1 1.5 0.4 0.6 0.4 1.5 0.4 197 3 198 165 13.3 0 13.5 13 08/16/2006 08:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 201 2 165 165 13.5 0 13.8 13.3 08/16/2006 08:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 203 1 165 165 13.9 0 14.1 13.3 08/16/2006 08:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 203 1 165 165 13.9 0.1 14.4 13.3 08/16/2006 08:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 192 24 165 165 14.2 0 14.4 13.5 08/16/2006 08:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0.1 1.1 0.4 137 2 165 165 14.1 0 14.6 13.8 08/16/2006 09:00:00 0.4 0.1 1.1 0.4 0.4 0.1 1.1 0.4 0.6 0.4 1.5 0.4 136 7 139 165 13.9 0 14.4 13.5 08/16/2006 09:10:00 0.4 0.1 0.7 0.4 0.4 0.1 1.1 0.4 0.5 0.3 1.5 0.4 111 1 112 165 13.4 0 13.8 13.3 08/16/2006 09:20:00 0.4 0 0.7 0.4 0.4 0 0.7 0.4 0.4 0.1 1.1 0.4 83 21 108 165 13.4 0.1 13.8 13.3 08/16/2006 09:30:00 1.2 0.5 2.3 0.4 0.8 0.4 1.9 0.4 1.5 0.6 3 0.4 359 22 3 165 14 0 14.4 13.8 08/16/2006 09:40:00 1 0.4 1.9 0.4 0.5 0.2 1.1 0.4 1.2 0.5 2.3 0.4 0 9 360 165 14.4 0.2 14.9 14.1 08/16/2006 09:50:00 0.4 0.2 1.5 0.4 0.4 0.1 1.5 0.4 0.4 0.1 1.1 0.4 19 41 95 165 14.8 0 14.9 14.6 08/16/2006 10:00:00 0.6 0.4 1.9 0.4 0.5 0.3 1.5 0.4 0.7 0.4 1.9 0.4 74 53 116 165 14.7 0 14.9 14.6 08/16/2006 10:10:00 1.2 0.7 2.6 0.4 0.9 0.5 2.3 0.4 1.1 0.7 2.6 0.4 22 64 347 165 15 0.1 15.2 14.6 08/16/2006 10:20:00 1.5 0.6 3 0.4 1 0.5 2.6 0.4 1.3 0.6 2.6 0.4 1 13 8 165 15.2 0 15.5 15.2 08/16/2006 10:30:00 0.8 0.6 2.6 0.4 0.7 0.6 2.6 0.4 0.9 0.7 2.6 0.4 93 51 23 165 15.3 0 15.7 15.2 08/16/2006 10:40:00 0.5 0.4 2.3 0.4 0.5 0.4 2.6 0.4 0.5 0.4 2.3 0.4 182 29 199 165 14.9 0.1 15.5 14.6 08/16/2006 10:50:00 1.3 1 4.2 0.4 1.1 0.9 4.2 0.4 1.2 1 5.3 0.4 314 90 63 165 15 0.1 15.7 14.9 08/16/2006 11:00:00 1.4 0.6 3 0.4 1.2 0.6 2.6 0.4 1.3 0.7 3.4 0.4 118 30 112 165 15.2 0.1 15.7 15.2 08/16/2006 11:10:00 1.2 0.6 2.6 0.4 1.2 0.6 3 0.4 1.2 0.6 3 0.4 98 33 147 165 15.2 0 16 15.2 08/16/2006 11:20:00 0.8 0.5 2.6 0.4 0.7 0.5 2.6 0.4 1 0.6 3 0.4 118 45 152 165 15.3 0 15.7 15.2 08/16/2006 11:30:00 1.1 0.8 3.4 0.4 1 0.7 3 0.4 1 0.7 3.4 0.4 87 26 100 165 15 0.1 15.7 14.6 08/16/2006 11:40:00 1.1 0.5 2.3 0.4 0.7 0.4 1.9 0.4 1 0.5 2.3 0.4 14 15 20 165 15 0 15.2 14.9 08/16/2006 11:50:00 0.8 0.6 2.3 0.4 0.6 0.4 2.3 0.4 0.8 0.5 2.3 0.4 34 41 15 165 15 0 15.7 14.6 08/16/2006 12:00:00 0.5 0.3 1.5 0.4 0.4 0.2 1.1 0.4 0.9 0.5 2.3 0.4 113 15 116 165 14.6 0 15.2 14.6 08/16/2006 12:10:00 0.7 0.5 2.6 0.4 0.6 0.4 2.3 0.4 0.8 0.5 2.3 0.4 102 22 54 165 14.6 0 14.6 14.6 08/16/2006 12:20:00 1.8 0.8 3.4 0.4 1.7 0.9 3 0.4 1.9 0.9 3.4 0.4 42 35 39 165 14.6 0 14.9 14.4 08/16/2006 12:30:00 2.4 0.5 4.2 0.4 2.3 0.5 3.4 0.4 2.3 0.5 3.4 0.4 45 10 43 165 14.7 0 15.2 14.4 08/16/2006 12:40:00 2.4 0.5 3.4 1.1 2.2 0.6 3.4 0.4 2.6 0.7 4.2 0.7 42 12 25 165 14.9 0 15.2 14.6 08/16/2006 12:50:00 2.3 0.5 3.4 0.7 2.2 0.5 3.4 0.4 2.5 0.5 3.8 1.1 37 14 40 165 15.2 0 15.7 15.2 08/16/2006 13:00:00 2.6 0.6 4.2 1.1 2.4 0.6 4.2 0.7 2.7 0.6 4.2 1.1 31 16 42 165 15.7 0 16.3 15.5 08/16/2006 13:10:00 2.7 0.5 4.2 1.1 2.5 0.5 3.8 1.1 2.8 0.5 3.8 1.1 36 11 61 165 15.5 0 16 15.2 08/16/2006 13:20:00 3.1 0.6 4.2 1.5 2.9 0.6 4.2 1.1 3.2 0.6 4.6 1.5 37 11 49 165 15.5 0 16 15.5 08/16/2006 13:30:00 3.2 0.6 4.9 1.1 3 0.6 4.6 1.5 3.2 0.6 4.9 1.1 41 11 32 165 15.3 0.2 16.3 15.2 08/16/2006 13:40:00 3.3 0.5 4.6 2.3 3.1 0.5 4.6 1.9 3.4 0.5 4.6 1.9 40 9 43 165 15.2 0 15.5 15.2 08/16/2006 13:50:00 3.3 0.6 6.1 1.9 3.1 0.7 5.7 1.5 3.1 0.7 4.9 0.7 49 16 72 165 15.1 0 15.5 14.9 08/16/2006 14:00:00 2.2 0.9 3.8 0.4 2 0.8 3.8 0.4 2.1 0.8 4.2 0.4 52 28 30 165 15.4 0.3 16.3 14.9 08/16/2006 14:10:00 2.4 0.8 4.2 0.4 2.2 0.8 4.2 0.4 2.4 0.7 4.2 0.4 67 35 130 165 16.2 0.2 16.8 15.7 08/16/2006 14:20:00 2.7 0.6 4.6 0.4 2.5 0.6 4.6 0.4 2.8 0.7 4.6 0.7 50 14 54 165 15.5 0.2 16 15.2 08/16/2006 14:30:00 3.1 0.6 4.6 0.4 2.9 0.7 4.6 0.4 3.2 0.7 4.6 0.7 43 9 40 165 15.2 0.1 15.7 15.2 08/16/2006 14:40:00 2.5 0.7 4.2 0.7 2.3 0.7 3.8 0.4 2.3 0.7 4.2 0.7 67 26 61 165 15.4 0 16 15.2 08/16/2006 14:50:00 2.5 0.8 4.9 0.4 2.3 0.8 4.9 0.4 2.2 0.6 4.2 0.7 74 30 104 165 15.7 0 16.3 15.5 08/16/2006 15:00:00 2.3 0.8 3.8 0.4 2.2 0.8 3.8 0.4 2.3 0.8 4.2 0.4 62 28 75 165 15.6 0.1 16.3 15.2 08/16/2006 15:10:00 3.1 0.4 4.2 1.5 2.9 0.5 3.8 1.1 3.1 0.5 4.2 1.5 45 8 54 165 15 0 15.5 14.9 08/16/2006 15:20:00 2.6 0.5 3.8 1.5 2.4 0.5 3.4 1.1 2.7 0.5 3.8 1.1 45 11 37 165 15 0.1 15.2 14.9 08/16/2006 15:30:00 2.8 0.4 3.8 1.1 2.6 0.4 3.4 1.5 2.9 0.4 3.8 1.9 49 9 49 165 14.9 0.1 15.5 14.6 08/16/2006 15:40:00 2.2 0.5 3 0.7 2 0.5 3 0.4 2.3 0.4 3 1.1 49 11 56 165 14.6 0 14.9 14.6 08/16/2006 15:50:00 1.9 0.6 3.4 0.4 1.8 0.6 3.4 0.4 2 0.6 3.4 0.4 57 15 52 165 14.6 0 14.9 14.6 08/16/2006 16:00:00 1.8 0.5 3.4 0.4 1.8 0.5 3.4 0.4 2.1 0.4 3.4 1.1 51 11 44 165 14.5 0 14.9 14.4 08/16/2006 16:10:00 2.1 0.6 3.4 0.4 2.2 0.6 3.4 0.4 2.3 0.6 3.4 1.1 43 11 48 165 14.6 0 14.9 14.6 08/16/2006 16:20:00 2.2 0.4 3 1.1 2.3 0.4 3.4 1.1 2.4 0.4 3.4 1.5 48 10 37 165 14.6 0 14.6 14.6 08/16/2006 16:30:00 2 0.4 3 0.7 2.2 0.4 3.4 0.7 2.2 0.5 3.4 1.1 46 11 59 165 14.6 0 14.9 14.6 08/16/2006 16:40:00 2.2 0.4 3 1.1 2.3 0.4 3 1.5 2.6 0.4 3.4 1.5 44 9 39 165 14.5 0 14.6 14.4 08/16/2006 16:50:00 2.1 0.4 3 1.1 2.1 0.4 3 1.1 2.2 0.6 3.4 0.7 46 11 44 165 14.4 0 14.6 14.4 08/16/2006 17:00:00 1.8 0.4 3 1.1 1.8 0.3 2.6 1.1 2 0.4 2.6 1.1 45 9 52 165 14.4 0 14.6 14.4 08/16/2006 17:10:00 1.4 0.5 2.3 0.4 1.4 0.5 2.3 0.4 1.6 0.5 2.6 0.4 69 21 33 165 14.4 0 14.9 14.4 08/16/2006 17:20:00 1.5 0.4 2.6 0.7 1.5 0.4 2.6 0.4 1.7 0.4 2.6 0.4 90 12 105 165 14.1 0.1 14.4 13.8 08/16/2006 17:30:00 1.8 0.5 2.6 0.4 1.8 0.5 3 0.4 1.9 0.5 3 0.4 89 11 91 165 13.9 0 14.1 13.8 08/16/2006 17:40:00 1 0.5 2.3 0.4 0.9 0.5 1.9 0.4 1.3 0.5 2.3 0.4 41 23 94 165 14.1 0 14.4 13.8 08/16/2006 17:50:00 1.5 0.4 2.6 0.7 1.4 0.4 2.3 0.7 2 0.3 3 1.1 38 9 34 165 13.9 0 14.4 13.5 08/16/2006 18:00:00 1 0.5 2.3 0.4 0.8 0.5 1.9 0.4 1.7 0.5 3 0.4 34 12 40 165 14 0.1 14.4 13.5 08/16/2006 18:10:00 0.6 0.4 1.9 0.4 0.4 0.2 1.9 0.4 0.8 0.5 1.9 0.4 22 29 9 165 14.5 0.1 14.9 14.4 08/16/2006 18:20:00 1.3 0.6 2.6 0.4 1 0.6 2.3 0.4 1.4 0.8 3 0.4 14 9 351 165 14.8 0 15.2 14.6 08/16/2006 18:30:00 2.1 0.4 3 1.1 2 0.5 3 0.4 2.5 0.3 3.4 1.5 31 9 10 165 14.4 0.2 15.2 14.1 08/16/2006 18:40:00 1.8 0.4 3 0.7 1.8 0.5 2.6 0.4 2 0.4 3 0.7 54 10 46 165 13.9 0 14.4 13.8 08/16/2006 18:50:00 1.3 0.4 2.3 0.4 1.1 0.5 2.3 0.4 1.6 0.3 2.6 0.7 40 15 67 165 13.9 0 14.1 13.8 08/16/2006 19:00:00 0.8 0.5 2.3 0.4 0.7 0.5 2.3 0.4 0.9 0.5 1.9 0.4 18 19 19 165 13.9 0.1 14.1 13.5 08/16/2006 19:10:00 1 0.5 2.3 0.4 0.7 0.4 2.3 0.4 1.3 0.5 2.6 0.4 358 16 351 165 13 0.3 13.5 12.5 08/16/2006 19:20:00 1.1 0.5 2.3 0.4 0.8 0.5 2.3 0.4 1.3 0.5 2.6 0.4 0 19 16 165 12.5 0.1 13 12.5 08/16/2006 19:30:00 1.3 0.4 2.3 0.4 1.2 0.5 2.3 0.4 1.7 0.3 2.6 0.7 8 20 348 165 12.3 0 12.5 11.9 08/16/2006 19:40:00 1.5 0.3 1.9 0.4 1.5 0.4 2.3 0.4 1.7 0.5 2.3 0.4 33 8 32 165 12.3 0 12.5 11.9 08/16/2006 19:50:00 1.4 0.3 2.3 0.4 1.1 0.6 2.3 0.4 1.8 0.3 2.3 0.7 15 18 19 165 12 0.2 12.5 11.4 08/16/2006 20:00:00 1.8 0.4 3 0.4 1.4 0.7 3 0.4 2 0.4 3 1.1 13 11 21 165 11.7 0 11.9 11.4 08/16/2006 20:10:00 2.2 0.2 2.6 1.9 2.1 0.2 2.6 1.5 2.7 0.2 3 1.9 17 3 19 165 11.5 0 11.7 11.4 08/16/2006 20:20:00 2.3 0.2 2.6 1.9 2 0.3 2.6 1.1 2.7 0.2 3 2.3 13 2 16 165 11.3 0 11.7 11.1 08/16/2006 20:30:00 1.9 0.2 2.6 1.5 1.8 0.3 2.3 1.1 2.3 0.3 3 1.5 23 7 21 165 11.3 0 11.4 11.1 08/16/2006 20:40:00 1.8 0.3 2.6 1.1 1.7 0.3 2.6 0.7 2.1 0.3 3 1.1 27 9 21 165 11.2 0 11.4 11.1 08/16/2006 20:50:00 2.5 0.2 3 1.9 2.5 0.3 3 1.9 2.8 0.2 3 2.3 25 5 29 165 11.1 0.1 11.4 10.9 08/16/2006 21:00:00 2.3 0.2 2.6 1.9 1.9 0.4 2.6 0.7 2.5 0.2 3 2.3 14 5 10 165 11 0.1 11.4 10.9 08/16/2006 21:10:00 2.7 0.2 3 2.3 2.4 0.3 3 1.9 2.8 0.2 3 2.3 21 1 22 165 10.9 0 11.1 10.6 08/16/2006 21:20:00 2.9 0.2 3.4 2.3 2.6 0.2 3 1.9 3 0.2 3.4 2.6 17 3 14 165 11 0.1 11.4 10.6 08/16/2006 21:30:00 2.8 0.3 3.4 2.3 2.3 0.5 3.4 1.1 3.1 0.2 3.4 2.6 13 1 14 165 11.1 0.1 11.4 10.6 08/16/2006 21:40:00 2.5 0.2 3 1.9 2.1 0.4 2.6 1.1 2.9 0.2 3.4 2.6 16 1 13 165 11.1 0.2 11.4 10.9 08/16/2006 21:50:00 2.4 0.2 3 1.9 1.4 0.6 2.6 0.4 3 0.2 3.4 2.6 11 5 19 165 11 0.2 11.4 10.6 08/16/2006 22:00:00 2.6 0.2 3 2.3 1.6 0.5 3 0.4 3.3 0.2 3.8 2.6 9 4 11 165 11.1 0.2 11.4 10.6 08/16/2006 22:10:00 2.4 0.2 3 1.9 2.1 0.3 2.6 1.1 3 0.3 3.4 2.3 16 2 15 165 11.3 0.2 11.9 10.9 08/16/2006 22:20:00 1.3 0.8 2.6 0.4 1.1 0.8 2.6 0.4 1.1 0.7 2.6 0.4 54 24 22 165 11.6 0.1 11.9 11.1 08/16/2006 22:30:00 2.3 0.7 3.4 0.4 2.2 0.9 3.4 0.4 2 1 3.8 0.4 41 8 39 165 11.5 0 11.7 11.1 08/16/2006 22:40:00 3.2 0.2 3.8 2.6 3.2 0.2 3.8 2.6 3.3 0.4 4.2 2.3 31 3 31 165 11.3 0.2 11.7 10.9 08/16/2006 22:50:00 3.1 0.3 3.4 2.6 3.1 0.3 3.4 2.3 3.1 0.4 3.8 1.9 35 8 26 165 11.1 0.2 11.4 10.9 08/16/2006 23:00:00 1.7 0.7 3 0.4 1.5 0.7 3 0.4 1.1 0.6 2.6 0.4 49 11 51 165 11.1 0.2 11.4 10.9 08/16/2006 23:10:00 2.9 0.3 3.4 2.3 2.8 0.3 3.4 1.9 2.6 0.3 3.4 1.9 36 4 33 165 11.2 0.2 11.4 10.9 08/16/2006 23:20:00 3.1 0.3 3.8 2.3 3 0.4 3.8 1.9 2.8 0.3 3.8 1.9 31 8 42 165 11.2 0.2 11.4 10.9 08/16/2006 23:30:00 3.4 0.2 3.8 3 3.3 0.2 3.8 2.6 3.4 0.3 3.8 1.9 28 4 22 165 11.3 0 11.4 10.9 08/16/2006 23:40:00 2.5 0.6 3.8 1.1 2.3 0.7 3.4 0.7 2.3 0.7 3.8 1.1 34 4 32 165 11.3 0 11.4 11.1 08/16/2006 23:50:00 2 0.3 2.6 1.1 1.8 0.4 2.6 0.7 1.8 0.4 2.6 0.7 34 6 31 165 11.3 0 11.4 11.1 08/17/2006 00:00:00 2.7 0.3 3.4 2.3 2.6 0.3 3.4 1.9 2.7 0.2 3 1.9 26 2 27 165 11.3 0 11.4 11.1 08/17/2006 00:10:00 2.6 0.3 3.4 2.3 2.1 0.7 3 0.4 2.6 0.2 3 1.9 18 8 26 165 11.3 0 11.4 10.9 08/17/2006 00:20:00 2.8 0.3 3.8 2.3 1.7 0.7 3.4 0.4 2.7 0.3 3.4 2.3 9 4 19 165 11.3 0 11.4 10.9 08/17/2006 00:30:00 3.4 0.3 3.8 2.6 2.6 0.7 3.8 0.7 3.3 0.4 4.2 2.3 14 5 9 165 11.3 0 11.4 10.9 08/17/2006 00:40:00 3.2 0.3 3.8 2.3 3 0.3 3.4 2.3 3.4 0.2 3.8 3 21 2 19 165 11.3 0 11.7 11.1 08/17/2006 00:50:00 2.4 0.3 3 1.5 2.2 0.3 3 1.5 2.3 0.7 3.4 0.7 33 9 23 165 11.6 0 11.7 11.4 08/17/2006 01:00:00 2.3 0.3 3 1.1 2.1 0.4 2.6 0.7 2 0.4 3 1.1 36 6 35 165 11.7 0 11.9 11.4 08/17/2006 01:10:00 2.2 0.3 2.6 1.5 2.1 0.3 2.6 0.7 2.3 0.4 3 1.5 25 4 32 165 11.7 0 11.9 11.4 08/17/2006 01:20:00 2.1 0.2 2.6 1.5 1.9 0.4 2.6 0.7 2.4 0.2 3 1.9 24 5 34 165 11.5 0 11.7 11.1 08/17/2006 01:30:00 1.6 0.2 1.9 1.1 1 0.2 1.5 0.4 2.1 0.2 2.6 1.9 19 1 19 165 11.5 0 11.7 11.1 08/17/2006 01:40:00 1.6 0.2 2.3 1.1 1.3 0.3 1.9 0.7 1.9 0.1 2.3 1.5 25 4 39 165 11.5 0 11.7 11.1 08/17/2006 01:50:00 1.6 0.2 2.3 1.1 1.2 0.4 2.3 0.4 1.9 0.1 2.3 1.5 27 4 34 165 11.5 0 11.7 11.1 08/17/2006 02:00:00 1.2 0.2 1.9 0.7 0.5 0.3 1.5 0.4 1.7 0.2 2.3 1.1 19 1 22 165 11.6 0 11.7 11.4 08/17/2006 02:10:00 0.9 0.2 1.1 0.7 0.4 0.1 0.7 0.4 1.6 0.2 1.9 1.1 19 0 19 165 11.5 0 11.7 11.1 08/17/2006 02:20:00 1 0.3 1.5 0.4 0.4 0.1 1.1 0.4 1.7 0.2 2.3 1.1 11 6 19 165 11.6 0 11.7 11.1 08/17/2006 02:30:00 0.5 0.2 1.1 0.4 0.4 0 0.4 0.4 1.3 0.2 1.9 0.7 359 2 7 165 11.5 0 11.7 11.1 08/17/2006 02:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.6 0.3 1.5 0.4 358 0 165 165 11.5 0 11.7 11.1 08/17/2006 02:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 358 0 165 165 11.5 0 11.7 11.1 08/17/2006 03:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 358 0 165 165 11.7 0.1 11.9 11.4 08/17/2006 03:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 358 0 165 165 11.7 0.1 11.9 11.4 08/17/2006 03:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 358 0 165 165 11.6 0.1 11.9 11.1 08/17/2006 03:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 358 0 165 165 11.6 0.1 11.9 11.1 08/17/2006 03:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 358 0 165 165 11.7 0.1 11.9 11.4 08/17/2006 03:50:00 0.8 0.5 1.9 0.4 0.4 0.1 0.7 0.4 1 0.5 1.9 0.4 0 2 2 165 11.8 0.1 11.9 11.4 08/17/2006 04:00:00 0.7 0.4 1.9 0.4 0.4 0.1 1.5 0.4 1.2 0.4 2.3 0.4 5 0 5 165 11.8 0.1 11.9 11.4 08/17/2006 04:10:00 1.6 0.2 2.3 1.1 1.3 0.3 1.9 0.7 1.9 0.2 2.6 1.5 25 5 17 165 11.8 0 11.9 11.4 08/17/2006 04:20:00 0.9 0.4 1.5 0.4 0.5 0.3 1.5 0.4 1.3 0.3 2.3 0.7 28 0 28 165 11.8 0.1 11.9 11.4 08/17/2006 04:30:00 1.2 0.2 1.9 0.7 0.9 0.4 1.9 0.4 1.6 0.2 2.3 1.1 43 10 44 165 11.9 0 11.9 11.4 08/17/2006 04:40:00 0.6 0.4 1.5 0.4 0.4 0.2 1.1 0.4 1.2 0.3 1.9 0.4 52 0 52 165 11.8 0.2 11.9 11.4 08/17/2006 04:50:00 0.4 0.1 1.1 0.4 0.4 0 0.4 0.4 0.8 0.3 1.5 0.4 34 3 52 165 11.7 0.2 11.9 11.4 08/17/2006 05:00:00 0.4 0.2 1.1 0.4 0.4 0 0.7 0.4 0.6 0.3 1.5 0.4 356 15 33 165 11.7 0.2 11.9 11.4 08/17/2006 05:10:00 0.4 0.2 1.5 0.4 0.4 0 0.4 0.4 0.6 0.4 1.5 0.4 1 8 11 165 11.6 0.2 11.9 11.4 08/17/2006 05:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 3 0 165 165 11.7 0.2 11.9 11.4 08/17/2006 05:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 301 33 165 165 11.7 0.3 11.9 11.4 08/17/2006 05:40:00 0.4 0.1 1.1 0.4 0.4 0 0.4 0.4 0.6 0.3 1.5 0.4 303 6 307 165 11.7 0.2 11.9 11.4 08/17/2006 05:50:00 0.5 0.3 1.5 0.4 0.4 0.2 1.5 0.4 0.6 0.4 1.9 0.4 289 10 273 165 11.7 0.2 11.9 11.4 08/17/2006 06:00:00 1.7 0.4 2.3 0.7 1.6 0.4 2.3 0.7 1.7 0.4 2.6 1.1 303 12 280 165 11.9 0 12.2 11.4 08/17/2006 06:10:00 1.5 0.5 2.6 0.4 1.4 0.6 2.6 0.4 1.6 0.4 3 0.4 303 10 301 165 12 0 12.2 11.4 08/17/2006 06:20:00 2 0.5 3.8 0.7 2 0.6 3.8 0.7 2.2 0.4 3.4 1.1 311 12 290 165 11.9 0.1 12.2 11.4 08/17/2006 06:30:00 0.9 0.6 2.3 0.4 0.8 0.6 2.3 0.4 1.3 0.5 2.6 0.4 308 18 311 165 11.9 0 12.2 11.1 08/17/2006 06:40:00 1.7 1 3.8 0.4 1.8 1 3.8 0.4 2 1 4.6 0.4 289 10 284 165 12.1 0 12.2 11.7 08/17/2006 06:50:00 3.1 0.6 4.2 1.5 3.1 0.6 4.2 1.5 2.7 0.5 4.2 1.1 303 6 302 165 12.1 0 12.2 11.7 08/17/2006 07:00:00 2.9 0.5 4.2 1.5 2.8 0.5 4.2 1.5 2.5 0.5 3.8 1.1 303 7 306 165 12.1 0 12.2 11.7 08/17/2006 07:10:00 3.4 0.4 4.2 2.3 3.3 0.4 4.2 2.3 2.8 0.4 3.8 1.5 297 6 295 165 12.1 0 12.2 11.7 08/17/2006 07:20:00 4 0.5 4.9 2.6 3.9 0.5 4.9 2.6 3.4 0.5 4.9 1.5 303 6 303 165 12.1 0 12.2 11.9 08/17/2006 07:30:00 3.6 0.6 4.9 2.3 3.5 0.6 4.9 1.9 3.1 0.6 4.9 1.9 301 10 289 165 12.1 0 12.2 11.7 08/17/2006 07:40:00 3.1 0.7 4.9 1.1 3 0.8 4.6 1.1 2.7 0.8 5.3 1.1 305 14 319 165 12 0 12.2 11.7 08/17/2006 07:50:00 3.8 0.7 5.3 1.9 3.7 0.7 5.3 1.9 3.1 0.6 4.9 1.9 300 11 296 165 12 0 12.2 11.7 08/17/2006 08:00:00 4.2 0.5 5.3 2.6 4.2 0.5 5.3 3 3.4 0.6 5.3 1.9 294 5 292 165 12.1 0 12.5 11.4 08/17/2006 08:10:00 4.4 0.5 5.7 3 4.4 0.6 5.7 2.6 3.7 0.7 5.3 2.3 293 6 298 165 12.2 0.1 12.5 11.7 08/17/2006 08:20:00 4.9 1 6.5 2.6 5 1 6.5 2.6 4.2 1 6.5 1.9 292 6 296 165 12.2 0.2 12.5 11.9 08/17/2006 08:30:00 5.1 0.4 6.1 4.2 5.2 0.4 6.5 4.2 4.8 0.6 6.5 3 287 4 285 165 12.3 0.1 12.5 11.9 08/17/2006 08:40:00 4.9 0.7 6.5 3 5 0.7 6.1 3 4.4 0.8 6.1 2.3 290 6 289 165 12.4 0.1 12.7 11.9 08/17/2006 08:50:00 4.8 0.6 6.5 3.4 4.9 0.6 6.5 3.4 4 0.6 5.7 2.6 292 7 296 165 12.3 0.1 12.7 11.9 08/17/2006 09:00:00 4.8 0.6 6.1 2.6 4.8 0.6 6.5 2.6 4 0.6 5.7 2.3 293 6 294 165 12.5 0.1 12.7 12.2 08/17/2006 09:10:00 4.2 0.7 6.1 2.6 4.2 0.7 5.7 2.6 3.5 0.8 5.7 1.9 293 9 298 165 12.9 0.1 13 12.5 08/17/2006 09:20:00 3.8 1 6.1 1.9 3.8 1 5.7 1.9 3.2 0.8 5.3 1.5 296 9 297 165 13.1 0 13.3 13 08/17/2006 09:30:00 4.2 0.7 5.7 2.6 4.2 0.7 5.7 2.6 3.7 0.7 5.7 1.9 303 9 295 165 13.5 0 13.5 13 08/17/2006 09:40:00 3.6 0.7 5.3 2.3 3.5 0.7 5.3 2.3 3 0.6 5.3 1.9 298 8 300 165 13.6 0 13.8 13.3 08/17/2006 09:50:00 1.3 0.6 3 0.4 1.1 0.7 3 0.4 1.7 0.6 3 0.4 314 22 297 165 13.7 0.1 14.1 13 08/17/2006 10:00:00 0.8 0.5 2.6 0.4 0.6 0.4 1.5 0.4 1 0.5 2.3 0.4 319 23 1 165 14.2 0 14.6 13.8 08/17/2006 10:10:00 0.6 0.4 2.3 0.4 0.5 0.3 1.9 0.4 0.5 0.3 1.5 0.4 239 53 320 165 14.7 0 14.9 14.6 08/17/2006 10:20:00 0.6 0.4 1.9 0.4 0.4 0.2 1.1 0.4 0.7 0.4 2.3 0.4 156 13 165 165 13.7 0.2 14.6 13.3 08/17/2006 10:30:00 1.5 0.4 2.6 0.4 1.3 0.5 2.6 0.4 1.8 0.5 3 0.4 131 16 117 165 13.3 0 13.5 13.3 08/17/2006 10:40:00 1.7 0.5 3.4 0.4 1.5 0.6 3.4 0.4 2 0.6 3.4 0.4 152 15 164 165 13.5 0 13.5 13.3 08/17/2006 10:50:00 1.7 0.4 2.6 0.4 1.5 0.4 2.6 0.4 2.1 0.4 3 1.1 137 9 135 165 13.7 0.2 14.4 13.3 08/17/2006 11:00:00 1.7 0.5 3 0.4 1.6 0.4 2.6 0.4 2.1 0.4 3 1.1 141 13 129 165 14.8 0.1 15.2 14.4 08/17/2006 11:10:00 1.6 0.5 3 0.4 1.4 0.6 3 0.4 2 0.5 3.4 0.7 158 11 152 165 15 0.2 15.7 14.4 08/17/2006 11:20:00 0.7 0.4 1.9 0.4 0.6 0.4 1.9 0.4 1.3 0.5 2.3 0.4 160 10 164 165 13.9 0.2 14.6 13.5 08/17/2006 11:30:00 0.8 0.4 1.9 0.4 0.6 0.3 1.5 0.4 1.2 0.4 2.3 0.4 155 15 166 165 13.2 0 13.5 13 08/17/2006 11:40:00 0.7 0.4 2.6 0.4 0.5 0.4 2.6 0.4 0.6 0.4 1.9 0.4 207 24 214 165 13 0 13.3 13 08/17/2006 11:50:00 0.9 0.5 2.3 0.4 0.8 0.6 2.6 0.4 1 0.7 3 0.4 221 28 208 165 13.7 0.2 14.1 13.3 08/17/2006 12:00:00 0.7 0.5 2.6 0.4 0.6 0.5 2.6 0.4 0.4 0.3 1.9 0.4 262 61 295 165 14.5 0.2 14.9 14.1 08/17/2006 12:10:00 0.4 0.2 1.5 0.4 0.4 0.2 1.1 0.4 0.5 0.3 1.5 0.4 230 13 222 165 14.6 0 15.2 14.4 08/17/2006 12:20:00 0.4 0.2 1.9 0.4 0.4 0.2 1.9 0.4 0.6 0.4 1.9 0.4 179 22 174 165 14.4 0 14.6 14.4 08/17/2006 12:30:00 0.5 0.4 2.3 0.4 0.5 0.4 2.3 0.4 0.5 0.3 1.5 0.4 207 39 229 165 15 0.2 15.5 14.6 08/17/2006 12:40:00 0.8 0.5 1.9 0.4 0.8 0.4 1.9 0.4 1.1 0.5 2.3 0.4 211 22 225 165 15.7 0.3 16.8 15.5 08/17/2006 12:50:00 1.3 0.6 3 0.4 1.2 0.6 2.6 0.4 1.5 0.5 2.6 0.4 193 16 226 165 15.9 0.2 16.8 15.7 08/17/2006 13:00:00 1 0.6 2.6 0.4 1 0.6 2.6 0.4 1.2 0.7 3 0.4 206 24 235 165 16.1 0.3 16.8 15.7 08/17/2006 13:10:00 1.2 0.5 2.6 0.4 1.2 0.5 2.6 0.4 1.5 0.6 3 0.4 188 15 164 165 16.4 0.1 16.8 16 08/17/2006 13:20:00 0.6 0.4 1.5 0.4 0.5 0.3 1.5 0.4 1 0.5 1.9 0.4 177 16 179 165 15.2 0.3 16.3 14.9 08/17/2006 13:30:00 0.4 0.2 1.5 0.4 0.4 0.2 1.5 0.4 0.8 0.5 2.3 0.4 186 22 153 165 15.4 0.1 15.7 15.2 08/17/2006 13:40:00 0.5 0.3 1.9 0.4 0.4 0.2 1.5 0.4 0.9 0.4 1.9 0.4 158 10 136 165 15.2 0.1 15.7 14.9 08/17/2006 13:50:00 1.4 0.6 3 0.4 1.3 0.7 3 0.4 1.8 0.6 3 0.4 145 13 143 165 15.5 0 15.7 15.5 08/17/2006 14:00:00 0.6 0.4 2.3 0.4 0.5 0.4 2.3 0.4 1.1 0.6 2.6 0.4 163 6 151 165 15.7 0 16 15.5 08/17/2006 14:10:00 0.9 0.6 3 0.4 0.8 0.6 2.6 0.4 1.1 0.6 2.6 0.4 150 17 156 165 16.2 0.1 16.6 16 08/17/2006 14:20:00 0.8 0.4 2.3 0.4 0.7 0.5 2.3 0.4 1.2 0.5 2.6 0.4 145 13 144 165 15.9 0.1 16.6 15.7 08/17/2006 14:30:00 0.4 0.1 1.1 0.4 0.4 0.1 1.5 0.4 0.8 0.5 2.3 0.4 153 12 159 165 16.1 0 16.6 16 08/17/2006 14:40:00 0.8 0.5 1.9 0.4 0.8 0.5 2.3 0.4 1.3 0.6 2.6 0.4 140 9 157 165 16 0 16.3 15.7 08/17/2006 14:50:00 0.9 0.6 2.6 0.4 0.9 0.6 2.3 0.4 1.2 0.5 2.6 0.4 135 12 116 165 16.5 0.1 17.1 16.3 08/17/2006 15:00:00 0.6 0.5 2.3 0.4 0.7 0.5 2.3 0.4 1.3 0.7 3 0.4 140 15 137 165 17.3 0.1 17.4 16.8 08/17/2006 15:10:00 1.3 0.6 3 0.4 1.3 0.6 3 0.4 1.7 0.5 3 0.4 142 16 151 165 17.2 0.2 17.7 16.6 08/17/2006 15:20:00 0.6 0.4 2.6 0.4 0.6 0.4 2.3 0.4 1 0.6 2.6 0.4 138 12 164 165 16.8 0 17.1 16.6 08/17/2006 15:30:00 1.7 0.5 2.6 0.4 1.8 0.5 3 0.4 2.1 0.4 3.8 1.5 143 10 183 165 16.6 0.1 17.1 16.3 08/17/2006 15:40:00 1.4 0.5 2.6 0.4 1.6 0.4 2.6 0.4 1.8 0.4 3 0.7 141 10 132 165 15.7 0.2 16.3 15.2 08/17/2006 15:50:00 1.3 0.3 2.3 0.4 1.7 0.3 2.6 1.1 1.6 0.3 2.6 0.7 144 10 136 165 15.8 0.2 16.3 15.5 08/17/2006 16:00:00 1.1 0.5 2.6 0.4 1.5 0.4 2.6 0.7 1.6 0.4 2.6 0.4 147 10 153 165 16.2 0 16.6 16 08/17/2006 16:10:00 1.1 0.5 2.6 0.4 1.5 0.4 2.6 0.7 1.6 0.4 2.6 0.7 160 11 157 165 16.5 0 16.8 16.3 08/17/2006 16:20:00 1.7 0.4 2.6 0.7 1.8 0.4 3 0.7 2 0.4 3 0.7 150 15 150 165 16.4 0.2 16.8 16 08/17/2006 16:30:00 1.6 0.5 2.6 0.4 1.8 0.5 3 0.4 1.9 0.5 3 0.7 136 13 147 165 16.2 0.1 16.6 16 08/17/2006 16:40:00 1.1 0.5 2.6 0.4 1.4 0.5 2.3 0.4 1.7 0.6 3 0.4 150 17 163 165 16.7 0.1 16.8 16.3 08/17/2006 16:50:00 0.9 0.5 2.3 0.4 1.1 0.5 2.3 0.4 1.5 0.4 2.3 0.7 159 12 153 165 16.4 0 16.8 16.3 08/17/2006 17:00:00 1.4 0.5 2.3 0.4 1.6 0.4 2.3 0.4 1.7 0.4 2.6 0.7 176 17 178 165 15.9 0 16.3 15.7 08/17/2006 17:10:00 1.5 0.5 2.6 0.4 1.7 0.5 2.6 0.4 1.9 0.5 3 0.4 188 13 165 165 15.9 0 16.6 15.7 08/17/2006 17:20:00 1.2 0.4 2.3 0.4 1.4 0.4 2.3 0.4 1.4 0.5 2.3 0.4 172 6 189 165 16.1 0 16.6 16 08/17/2006 17:30:00 1.1 0.3 2.3 0.4 1.3 0.3 2.3 0.4 1.5 0.4 3 0.4 164 8 156 165 16.7 0.3 17.4 16.3 08/17/2006 17:40:00 1.1 0.4 1.9 0.4 1.3 0.3 2.3 0.4 1.7 0.3 2.6 1.1 162 4 155 165 17 0 17.4 16.8 08/17/2006 17:50:00 1 0.3 1.9 0.4 1.1 0.3 1.9 0.4 1.6 0.3 2.3 1.1 168 3 172 165 16.9 0.1 17.1 16.8 08/17/2006 18:00:00 0.4 0.2 1.5 0.4 0.4 0.2 1.9 0.4 1 0.4 1.9 0.4 169 8 164 165 17.3 0.2 17.7 16.8 08/17/2006 18:10:00 0.9 0.4 1.9 0.4 1 0.4 1.9 0.4 1.4 0.4 2.3 0.4 183 9 179 165 17.3 0 17.7 17.1 08/17/2006 18:20:00 1.5 0.4 2.3 0.4 1.7 0.4 2.6 0.4 1.8 0.4 2.6 0.7 200 8 204 165 17.1 0.2 17.7 16.8 08/17/2006 18:30:00 1.9 0.4 2.6 0.7 2.1 0.4 3 0.7 2.3 0.4 3 1.1 192 17 206 165 16.6 0.2 17.1 16.3 08/17/2006 18:40:00 1.6 0.3 2.3 0.7 1.7 0.3 2.3 1.1 1.6 0.4 2.6 0.7 182 10 182 165 16.6 0 16.8 16.3 08/17/2006 18:50:00 1.3 0.3 1.9 0.4 1.4 0.4 2.3 0.7 1.4 0.3 2.3 0.4 205 13 201 165 16.8 0 17.1 16.8 08/17/2006 19:00:00 1.4 0.3 2.3 0.7 1.6 0.3 2.3 0.7 1.6 0.3 2.3 0.7 212 3 213 165 16.4 0.3 17.1 16 08/17/2006 19:10:00 1.1 0.5 2.3 0.4 1.3 0.5 2.3 0.4 1.3 0.4 2.3 0.4 214 1 212 165 15.7 0 16 15.7 08/17/2006 19:20:00 0.7 0.3 1.1 0.4 0.8 0.3 1.5 0.4 1 0.2 1.5 0.4 196 7 198 165 15.7 0 16.3 15.7 08/17/2006 19:30:00 0.8 0.4 2.3 0.4 0.9 0.4 1.9 0.4 1 0.5 2.3 0.4 191 2 186 165 16.1 0 16.3 16 08/17/2006 19:40:00 1.1 0.4 2.3 0.4 1.2 0.4 2.3 0.4 1.1 0.4 2.3 0.4 187 8 184 165 15.9 0.1 16.3 15.7 08/17/2006 19:50:00 1 0.3 1.5 0.4 1.1 0.2 1.9 0.7 1.4 0.2 1.9 0.7 200 5 205 165 15.7 0 16 15.5 08/17/2006 20:00:00 1.7 0.2 2.3 1.1 1.9 0.2 2.3 1.1 1.9 0.4 2.6 1.1 202 5 201 165 15.2 0 15.5 15.2 08/17/2006 20:10:00 0.6 0.4 1.9 0.4 0.7 0.5 1.9 0.4 0.7 0.5 2.3 0.4 205 4 204 165 14.8 0.1 15.5 14.6 08/17/2006 20:20:00 1.6 0.5 2.3 0.4 1.7 0.5 2.6 0.7 1.5 0.3 2.3 0.7 185 7 178 165 14.6 0 14.9 14.4 08/17/2006 20:30:00 0.8 0.6 2.3 0.4 1 0.6 2.3 0.4 1.4 0.5 2.3 0.4 200 2 203 165 14.6 0 14.9 14.4 08/17/2006 20:40:00 0.7 0.6 2.6 0.4 0.9 0.7 2.6 0.4 1.5 0.4 2.6 0.7 200 5 179 165 14.7 0 14.9 14.6 08/17/2006 20:50:00 2.2 0.3 2.6 1.5 2.3 0.2 3 1.5 2.7 0.3 3.4 2.3 200 5 179 165 14.6 0 14.9 14.6 08/17/2006 21:00:00 1.8 0.4 2.6 1.1 1.9 0.4 3 1.1 2.4 0.4 3.4 1.5 198 3 204 165 14.6 0 14.9 14.4 08/17/2006 21:10:00 0.6 0.3 1.1 0.4 0.7 0.4 1.5 0.4 1.1 0.5 1.9 0.4 197 1 198 165 14.8 0 15.2 14.4 08/17/2006 21:20:00 0.7 0.3 1.5 0.4 0.5 0.3 1.5 0.4 0.7 0.4 1.9 0.4 204 7 210 165 14.8 0 14.9 14.4 08/17/2006 21:30:00 1.6 0.3 2.3 1.1 1.7 0.3 2.3 1.1 1.9 0.3 2.6 1.1 202 3 202 165 15.1 0.1 15.5 14.6 08/17/2006 21:40:00 1.9 0.2 2.3 1.5 2 0.2 2.6 1.5 2.4 0.2 2.6 1.9 199 1 202 165 15.1 0.1 15.2 14.6 08/17/2006 21:50:00 1.3 0.3 2.3 0.7 1.5 0.3 2.3 0.7 1.9 0.3 2.6 1.5 200 1 198 165 15.1 0.1 15.2 14.6 08/17/2006 22:00:00 1.4 0.4 2.3 0.7 1.5 0.3 2.3 1.1 1.9 0.2 2.3 1.5 207 6 205 165 15.2 0 15.5 14.6 08/17/2006 22:10:00 1.4 0.4 2.3 0.4 1.5 0.5 2.3 0.4 1.7 0.3 2.3 1.1 215 10 202 165 15.2 0 15.5 14.6 08/17/2006 22:20:00 0.8 0.4 1.9 0.4 0.9 0.4 1.9 0.4 1.2 0.4 2.3 0.4 214 9 205 165 15.5 0 15.7 15.2 08/17/2006 22:30:00 0.7 0.4 1.5 0.4 0.7 0.5 1.5 0.4 0.9 0.5 1.5 0.4 224 15 236 165 15.2 0.1 15.7 14.9 08/17/2006 22:40:00 0.9 0.2 1.5 0.4 0.9 0.3 1.5 0.4 1.3 0.2 1.5 0.7 242 3 236 165 15.2 0 15.7 14.9 08/17/2006 22:50:00 0.4 0.2 1.1 0.4 0.4 0.1 1.5 0.4 0.6 0.4 1.5 0.4 264 9 243 165 15.5 0.1 15.7 15.2 08/17/2006 23:00:00 0.4 0.1 1.1 0.4 0.4 0 0.7 0.4 0.4 0.1 1.1 0.4 260 5 273 165 15 0 15.5 14.6 08/17/2006 23:10:00 0.5 0.3 1.5 0.4 0.5 0.3 1.1 0.4 0.5 0.2 1.5 0.4 267 6 271 165 14.6 0 14.9 14.6 08/17/2006 23:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 198 45 165 165 14.4 0 14.6 14.4 08/17/2006 23:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.5 0.3 1.1 0.4 156 6 165 165 14.2 0.1 14.6 13.8 08/17/2006 23:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 157 20 165 165 14 0 14.1 13.8 08/17/2006 23:50:00 0.5 0.2 1.5 0.4 0.4 0 0.4 0.4 0.7 0.2 1.1 0.4 246 12 265 165 13.9 0.1 14.4 13.5 08/18/2006 00:00:00 0.5 0.2 1.1 0.4 0.4 0.1 1.1 0.4 0.4 0.1 0.7 0.4 278 9 282 165 13.7 0.1 14.1 13.3 08/18/2006 00:10:00 0.4 0 0.7 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 286 0 286 165 13.7 0 13.8 13.3 08/18/2006 00:20:00 1.5 0.5 2.6 0.4 1.3 0.6 2.6 0.4 1.1 0.5 2.3 0.4 300 9 305 165 13.6 0.1 13.8 13 08/18/2006 00:30:00 2.1 0.2 2.6 1.5 2.1 0.2 2.6 1.1 2 0.2 2.6 1.5 311 7 305 165 13.7 0 13.8 13.3 08/18/2006 00:40:00 1.9 0.3 2.6 1.1 1.8 0.4 3 0.7 1.9 0.3 2.6 1.1 321 10 300 165 13.7 0 13.8 13.3 08/18/2006 00:50:00 2.6 0.5 3.8 1.5 2.5 0.5 3.8 1.1 2.8 0.5 4.6 1.9 327 12 325 165 13.7 0.1 13.8 13 08/18/2006 01:00:00 2.1 0.6 3.8 0.7 2 0.7 3.8 0.4 1.8 0.7 3 0.4 306 8 308 165 14 0.2 14.4 13.3 08/18/2006 01:10:00 0.9 0.4 1.9 0.4 0.6 0.3 1.5 0.4 0.7 0.3 1.5 0.4 281 12 282 165 14 0.2 14.4 13.3 08/18/2006 01:20:00 2.2 0.4 3 1.5 2.3 0.5 3.4 1.1 1.9 0.5 3 0.7 283 8 289 165 14.2 0 14.6 14.1 08/18/2006 01:30:00 1.8 0.4 2.6 0.7 1.9 0.3 2.6 1.1 1.9 0.3 2.6 1.1 275 6 273 165 14.2 0.1 14.6 13.8 08/18/2006 01:40:00 2.3 0.2 3 1.5 2.3 0.3 2.6 1.5 2 0.4 2.6 0.7 287 6 292 165 14.2 0 14.6 13.8 08/18/2006 01:50:00 2.1 0.3 2.6 1.1 2.4 0.2 2.6 1.9 2.4 0.2 3 1.9 269 4 278 165 14.6 0 14.6 14.4 08/18/2006 02:00:00 2.7 0.8 3.8 1.1 3.3 0.4 4.2 1.9 3.1 0.5 4.2 1.9 272 7 274 165 14.1 0.3 14.9 13 08/18/2006 02:10:00 3.5 0.2 4.2 3 3.6 0.3 4.2 3 3.6 0.3 4.2 3 283 3 281 165 13.7 0 13.8 13 08/18/2006 02:20:00 3.1 0.8 4.6 1.5 3.7 0.5 4.9 2.6 3.3 0.6 4.6 1.9 273 7 276 165 13.7 0.1 13.8 13 08/18/2006 02:30:00 1.8 0.7 3.4 0.4 2.1 0.9 3.4 0.4 1.8 0.8 3.4 0.4 253 32 273 165 13.5 0 13.5 13 08/18/2006 02:40:00 1.8 0.5 3.4 0.7 1.8 0.5 3 0.7 1.9 0.5 2.6 0.4 216 13 231 165 13.4 0 13.5 13.3 08/18/2006 02:50:00 3.2 0.6 4.2 1.5 3.3 0.6 4.2 1.9 3.2 0.6 4.2 1.5 272 23 282 165 13.4 0.1 13.8 13 08/18/2006 03:00:00 1.1 0.9 3.8 0.4 1.2 0.9 3.8 0.4 1.1 0.9 3.4 0.4 247 29 279 165 13.5 0.1 13.8 13 08/18/2006 03:10:00 2.5 1.1 4.2 0.4 2.8 1.3 4.6 0.4 2.4 1.4 4.6 0.4 266 23 268 165 13.1 0.2 13.5 12.7 08/18/2006 03:20:00 3.7 0.4 4.6 1.9 4 0.3 4.6 3.4 3.7 0.4 4.6 2.3 277 3 278 165 13.8 0 14.1 13.5 08/18/2006 03:30:00 3 0.6 4.2 1.5 3.5 0.4 4.6 1.9 3.3 0.4 4.2 2.3 270 7 270 165 13.4 0 13.8 13 08/18/2006 03:40:00 2.4 0.4 3 1.5 2.9 0.3 3.4 2.3 2.9 0.3 3.8 2.3 264 6 274 165 13.7 0 14.1 13.3 08/18/2006 03:50:00 3.1 0.4 4.2 1.9 3.3 0.4 4.6 2.6 3.3 0.3 4.2 2.6 273 4 270 165 14 0.1 14.1 13.3 08/18/2006 04:00:00 2.3 0.3 3 1.5 2.5 0.3 3 1.9 2.5 0.3 3.4 1.9 277 3 276 165 14.1 0.1 14.4 13.5 08/18/2006 04:10:00 1.4 0.4 2.3 0.7 1.6 0.4 2.3 0.7 1.7 0.3 2.3 1.1 276 8 269 165 14.3 0 14.6 13.5 08/18/2006 04:20:00 1 0.4 1.5 0.4 1.1 0.4 1.9 0.4 1.5 0.5 2.3 0.4 217 22 239 165 14.3 0.2 14.6 13.3 08/18/2006 04:30:00 0.9 0.5 2.3 0.4 1 0.6 2.3 0.4 1.6 0.4 2.3 0.7 226 9 242 165 13.8 0 13.8 13.3 08/18/2006 04:40:00 2.2 0.5 3 1.1 2.3 0.5 3 1.1 2.5 0.3 3.4 1.9 210 14 211 165 13.5 0.1 13.8 13 08/18/2006 04:50:00 2.7 0.2 3.4 2.3 2.7 0.2 3.4 2.3 2.9 0.2 3.4 2.3 193 7 199 165 13.5 0.1 13.8 13 08/18/2006 05:00:00 2.9 0.2 3.4 2.3 2.9 0.2 3.4 2.3 3 0.2 3.4 2.6 195 6 192 165 13.7 0.2 14.1 13 08/18/2006 05:10:00 2.6 0.2 3 2.3 2.6 0.2 3 2.3 2.8 0.2 3.4 2.3 181 3 178 165 13.7 0.1 14.1 13 08/18/2006 05:20:00 2.2 0.3 3 1.5 2.1 0.4 3 1.1 2.3 0.4 3 1.5 188 6 205 165 13.3 0 13.5 12.7 08/18/2006 05:30:00 3.5 0.5 4.2 2.3 3.6 0.5 4.2 2.3 3.6 0.5 4.6 2.3 209 5 211 165 13.6 0 13.8 13 08/18/2006 05:40:00 2.1 0.7 3 0.4 2.2 0.7 3.4 0.4 2.1 1 3.4 0.4 221 12 219 165 13.5 0.3 14.1 12.7 08/18/2006 05:50:00 2.3 0.5 4.2 1.1 2.3 0.6 4.2 1.1 2.4 0.5 4.2 1.5 191 11 201 165 13.5 0 13.8 13 08/18/2006 06:00:00 2.3 0.5 3.8 1.1 2.3 0.5 3.8 1.1 2.3 0.5 3.8 1.1 203 8 198 165 13.7 0 13.8 13 08/18/2006 06:10:00 2.2 0.6 3.8 0.4 2.3 0.7 3.4 0.4 2.5 0.6 3.4 0.4 210 66 296 165 13.7 0.2 14.1 12.7 08/18/2006 06:20:00 1.9 0.5 2.6 0.4 2 0.6 3 0.4 2 0.6 3 0.4 238 18 230 165 13.3 0.3 13.8 12.7 08/18/2006 06:30:00 2.6 0.2 3.4 1.9 2.7 0.3 3.4 2.3 2.8 0.3 3.4 2.3 215 5 215 165 13.8 0 13.8 13.3 08/18/2006 06:40:00 2.9 0.4 3.8 1.9 3 0.4 3.8 2.3 3 0.5 4.2 2.3 214 3 212 165 13.8 0 14.1 13.3 08/18/2006 06:50:00 2.6 0.4 3.4 1.5 2.7 0.4 3.4 1.5 2.8 0.4 3.4 1.9 215 4 213 165 13.9 0 14.1 13.5 08/18/2006 07:00:00 1.3 0.5 2.3 0.4 1.4 0.5 2.3 0.4 1.5 0.5 2.3 0.7 224 5 228 165 14 0.1 14.4 13.3 08/18/2006 07:10:00 0.9 0.3 1.9 0.4 0.9 0.4 1.9 0.4 0.8 0.3 1.5 0.4 214 15 239 165 14.1 0.2 14.6 13.5 08/18/2006 07:20:00 1.1 0.5 2.3 0.4 1.2 0.5 2.3 0.4 1.1 0.5 2.3 0.4 238 9 233 165 14.8 0.2 15.5 13.8 08/18/2006 07:30:00 0.7 0.4 1.5 0.4 0.8 0.5 1.9 0.4 0.8 0.4 1.9 0.4 222 32 244 165 15.8 0.1 16.3 15.5 08/18/2006 07:40:00 0.6 0.3 1.5 0.4 0.6 0.3 1.5 0.4 0.7 0.4 1.5 0.4 186 23 210 165 15.9 0.2 16.6 15.7 08/18/2006 07:50:00 1.7 0.6 3 0.4 1.8 0.5 3 0.4 1.7 0.5 3 0.4 195 13 197 165 16.2 0.2 16.8 15.7 08/18/2006 08:00:00 2 0.6 3.4 0.4 2 0.6 3.4 0.7 1.8 0.6 3 0.4 193 17 201 165 15.7 0.2 16 15.2 08/18/2006 08:10:00 2.4 0.6 3.8 0.7 2.4 0.6 3.4 0.7 2.1 0.6 3.8 0.4 198 17 187 165 15 0.2 15.2 14.6 08/18/2006 08:20:00 2.4 0.7 3.8 0.7 2.5 0.6 4.2 0.7 2.4 0.6 4.2 0.7 200 15 213 165 15.3 0.2 15.7 14.9 08/18/2006 08:30:00 2 0.7 3.8 0.4 2.1 0.7 3.8 0.4 2 0.5 3 0.7 186 20 183 165 15.4 0.2 15.7 14.9 08/18/2006 08:40:00 2.4 0.6 3.8 0.4 2.5 0.6 4.2 1.1 2.4 0.6 4.2 0.4 189 20 164 165 15.7 0.1 16.3 15.5 08/18/2006 08:50:00 2.3 0.7 4.2 0.7 2.4 0.7 4.2 0.4 2.4 0.6 4.2 1.1 191 20 206 165 15.6 0.2 16 15.2 08/18/2006 09:00:00 2.8 0.7 4.6 0.7 2.9 0.7 4.9 1.1 2.9 0.8 5.3 0.4 176 18 196 165 15.9 0 16.3 15.7 08/18/2006 09:10:00 2.9 1 4.6 0.7 3 0.9 4.9 0.7 3 1 4.9 0.7 186 17 175 165 15.5 0.3 16.6 15.2 08/18/2006 09:20:00 3.5 1 6.1 0.7 3.7 0.9 6.1 1.1 3.5 1 6.1 0.7 196 21 194 165 16.1 0.5 16.8 15.5 08/18/2006 09:30:00 3.6 0.8 5.3 1.9 3.7 0.8 5.3 2.3 3.9 0.9 6.5 1.9 190 14 196 165 16.2 0.3 17.1 15.7 08/18/2006 09:40:00 2.9 0.9 4.9 0.7 3 0.8 5.3 1.1 2.9 0.8 4.9 1.1 195 15 186 165 15.4 0 15.7 15.2 08/18/2006 09:50:00 3.6 0.9 5.7 1.1 3.7 0.9 5.7 1.1 3.6 1 5.7 1.5 199 13 206 165 15.7 0.3 16.3 15.5 08/18/2006 10:00:00 5.2 0.9 7.6 3 5.4 0.9 7.6 3 5.2 0.9 7.2 2.6 200 12 194 165 16.2 0.2 16.8 16 08/18/2006 10:10:00 5.3 0.8 6.8 3 5.4 0.8 6.8 3 5.5 1 7.6 3.4 203 8 205 165 16.7 0.3 17.1 16.3 08/18/2006 10:20:00 4.9 0.7 7.6 3 5.1 0.7 8 3 4.9 0.7 6.8 2.6 201 12 203 165 16.4 0 16.8 16.3 08/18/2006 10:30:00 6.9 1 9.5 4.6 6.9 1 9.9 4.6 7.2 1 9.9 4.9 198 8 194 165 17.1 0.5 18 16.6 08/18/2006 10:40:00 8.6 0.8 10.3 5.7 8.7 0.8 10.3 5.7 9 0.9 11.5 6.5 197 6 196 165 17.5 0.2 18 16.8 08/18/2006 10:50:00 7.2 1 9.5 3.8 7.3 1 9.9 4.2 7.3 1 9.9 4.6 200 8 204 165 16.1 0.1 16.8 16 08/18/2006 11:00:00 7 0.9 9.5 3.8 7.2 0.9 10.3 4.2 7 1 9.1 4.6 201 9 193 165 15.9 0 16.3 15.7 08/18/2006 11:10:00 7.4 0.9 9.1 4.9 7.5 1 9.5 4.9 7.6 0.9 9.5 5.3 194 8 201 165 16 0 16.3 15.7 08/18/2006 11:20:00 7.7 1 9.9 5.3 7.7 1 9.9 4.9 7.9 1 10.3 5.3 192 9 192 165 16.6 0.1 16.8 16.3 08/18/2006 11:30:00 7.2 1 9.5 4.6 7.2 0.9 9.1 4.6 7.4 0.9 9.9 4.9 184 11 199 165 16.5 0 16.8 16.3 08/18/2006 11:40:00 6.3 1 9.1 4.2 6.4 0.9 9.1 4.2 6.6 1 9.1 4.2 185 11 181 165 16.3 0 16.6 16.3 08/18/2006 11:50:00 7.9 1.1 10.3 4.9 7.9 1.1 10.3 4.9 8 1.1 10.3 5.3 193 8 195 165 16.4 0 16.6 16.3 08/18/2006 12:00:00 7.2 1 9.5 4.9 7.2 1 9.5 4.9 7.4 0.9 10.3 4.9 191 11 199 165 16.6 0 16.8 16.3 08/18/2006 12:10:00 8.3 1.2 11.5 4.9 8.4 1.2 11.1 5.3 8.5 1.2 11.5 5.7 196 8 193 165 16.2 0 16.6 16 08/18/2006 12:20:00 8.2 1.2 10.7 4.9 8.3 1.2 10.7 4.9 8.4 1.2 11.1 4.2 199 9 206 165 15.7 0.1 16.3 15.7 08/18/2006 12:30:00 8.2 1.1 10.7 5.3 8.3 1 11.1 5.7 8.2 1 10.7 4.9 200 7 201 165 15.6 0 15.7 15.7 08/18/2006 12:40:00 8.3 1.2 10.7 5.3 8.3 1.1 10.7 5.7 8.3 1 11.5 5.3 195 8 190 165 15.5 0 15.7 15.5 08/18/2006 12:50:00 7.9 1.3 11.1 4.6 8 1.3 10.7 4.9 7.9 1.3 11.5 5.3 196 8 198 165 15.6 0 15.7 15.5 08/18/2006 13:00:00 8.1 1 11.1 5.3 8.1 1 11.1 5.7 8.2 1 10.7 5.7 192 9 203 165 16.3 0.7 17.4 15.7 08/18/2006 13:10:00 7.4 1.1 10.3 4.6 7.3 1 10.7 4.6 7.4 1.1 10.3 3.4 177 13 184 165 17.9 0.3 18.5 17.4 08/18/2006 13:20:00 6.5 1 9.9 3.8 6.5 1 10.3 4.2 6.7 0.9 9.1 4.2 171 19 199 165 17.3 0.1 18 16.8 08/18/2006 13:30:00 7.8 1.3 11.5 3.8 7.9 1.3 11.5 4.2 7.9 1.4 11.1 4.2 191 15 196 165 17.7 0.3 18.2 17.1 08/18/2006 13:40:00 7.8 1.1 10.7 4.6 7.9 1.1 11.1 5.3 7.8 1 10.3 4.9 196 10 210 165 16.6 0.3 17.4 16.3 08/18/2006 13:50:00 7.2 1.1 10.3 4.2 7.3 1 10.3 4.6 7.2 1.1 10.3 4.9 198 13 215 165 16.1 0 16.8 16 08/18/2006 14:00:00 8.8 1.3 11.5 4.9 9 1.3 11.8 4.9 8.7 1.5 12.6 5.3 202 9 206 165 16.1 0 16.3 16 08/18/2006 14:10:00 8.7 1.1 11.5 6.1 8.9 1.1 11.5 6.1 8.6 1.1 11.5 5.7 208 7 211 165 16.4 0 16.6 16.3 08/18/2006 14:20:00 8.9 1.5 13 4.9 9.1 1.5 13.3 5.3 9 1.4 13 6.1 211 9 231 165 17.2 0.4 18 16.6 08/18/2006 14:30:00 9 1 11.8 6.1 9.3 1.1 11.8 6.5 9 1.1 11.8 6.5 219 7 221 165 17 0.5 18.2 16 08/18/2006 14:40:00 7.2 1 9.1 4.2 7.5 1 9.5 4.6 7.2 1.2 9.9 3.4 212 8 216 165 15.7 0.1 16 15.5 08/18/2006 14:50:00 6.4 1.2 9.1 3 6.6 1.2 9.1 3.4 6.3 1.2 9.1 3.4 208 8 211 165 15.5 0 15.7 15.5 08/18/2006 15:00:00 5.7 0.8 8 3 5.8 0.8 8.4 3.4 5.8 0.9 8.8 3.4 202 13 196 165 15.9 0 16.3 15.7 08/18/2006 15:10:00 6.7 1.2 9.5 3.8 6.8 1.3 9.5 3.8 6.6 1.3 9.5 3 205 13 213 165 15.9 0 16.3 15.7 08/18/2006 15:20:00 8.4 1.1 11.1 4.9 8.6 1.1 11.1 5.3 8.3 1.2 11.5 5.3 212 8 211 165 15.7 0 16 15.7 08/18/2006 15:30:00 8.1 1.3 11.8 4.6 8.2 1.3 11.8 4.9 8.2 1.2 11.5 5.3 206 9 194 165 15.5 0 15.7 15.5 08/18/2006 15:40:00 8.4 1.1 10.7 5.7 8.5 1 10.7 5.7 8.5 1 11.1 5.7 201 7 203 165 15.3 0 15.7 15.2 08/18/2006 15:50:00 9 1 11.5 5.7 9.1 1 11.5 5.7 9.2 1.1 12.2 6.1 200 9 197 165 15.2 0 15.5 15.2 08/18/2006 16:00:00 9 1.5 13 5.7 9.1 1.5 12.6 5.7 8.8 1.5 12.2 5.3 206 10 203 165 15 0 15.2 14.9 08/18/2006 16:10:00 8.9 1.3 12.6 5.7 9.1 1.3 12.6 6.1 8.8 1.5 12.2 4.9 213 7 211 165 14.8 0 15.2 14.6 08/18/2006 16:20:00 9.2 1.4 12.6 4.9 9.4 1.5 13 5.3 9 1.3 13 6.1 207 10 205 165 14.6 0 15.2 14.4 08/18/2006 16:30:00 9.3 1.8 13.7 5.3 9.4 1.8 13.3 5.3 9.4 1.7 14.5 6.1 197 9 197 165 14.5 0 14.6 14.4 08/18/2006 16:40:00 8.8 1.3 13 6.1 8.8 1.3 13 6.1 9 1.4 13 5.3 194 10 180 165 14.6 0 14.6 14.6 08/18/2006 16:50:00 10.7 1 12.6 8 10.7 1.1 13 7.6 10.8 1.5 13.7 7.2 195 8 193 165 14.3 0 14.6 14.1 08/18/2006 17:00:00 10.4 1.4 13.7 6.1 10.4 1.4 13.7 5.7 10.6 1.4 14.5 6.8 196 7 200 165 14.1 0 14.4 14.1 08/18/2006 17:10:00 10.3 1.3 13.3 5.7 10.3 1.3 13 6.1 10.3 1.4 13.3 7.2 196 7 192 165 14 0 14.1 13.8 08/18/2006 17:20:00 9.7 1.3 13.3 6.8 9.7 1.3 13.7 6.8 9.6 1.3 13.3 6.1 193 8 190 165 13.8 0 14.1 13.5 08/18/2006 17:30:00 9 1.6 12.6 4.9 9 1.6 12.2 4.9 9 1.6 12.6 4.9 193 10 203 165 13.7 0 13.8 13.3 08/18/2006 17:40:00 9.9 1.2 12.6 6.5 9.9 1.2 12.6 6.8 10.1 1.4 13.3 6.5 193 8 194 165 13.5 0 13.8 13.3 08/18/2006 17:50:00 10.2 1.3 14.1 6.8 10.2 1.3 14.1 6.8 10.2 1.4 13.7 6.8 194 8 201 165 13.4 0 13.5 13 08/18/2006 18:00:00 10.9 1.2 13.3 7.2 10.9 1.2 13.3 7.6 11 1.1 13.3 8.4 194 7 193 165 13.3 0 13.5 12.7 08/18/2006 18:10:00 10.5 1.5 14.1 6.8 10.5 1.5 14.1 6.8 10.7 1.5 13.7 7.2 193 6 193 165 13.3 0 13.5 13 08/18/2006 18:20:00 9 1.4 12.2 5.3 9 1.3 12.2 5.7 9 1.5 13 6.1 190 9 194 165 13.2 0 13.3 13 08/18/2006 18:30:00 7.2 1.3 10.3 4.2 7.2 1.3 9.9 3.8 7.3 1.2 10.7 4.2 191 12 204 165 13.2 0 13.3 13 08/18/2006 18:40:00 7.6 1.1 9.9 4.6 7.7 1.1 9.9 4.6 7.6 1.1 9.9 4.9 200 9 190 165 13.2 0 13.3 13 08/18/2006 18:50:00 8 1 10.3 4.9 8.2 1 10.3 4.9 7.9 1.3 10.7 4.6 206 7 199 165 13.1 0 13.3 13 08/18/2006 19:00:00 7.3 1.3 10.3 4.2 7.5 1.3 10.3 4.2 7.4 1.4 10.7 4.2 204 9 199 165 13.1 0 13.3 13 08/18/2006 19:10:00 5.9 1.4 11.5 3 6 1.4 11.5 3 5.9 1.3 11.1 3.4 205 11 197 165 12.9 0 13 12.7 08/18/2006 19:20:00 5.5 1 8 3 5.5 1 8 3 5.7 1 8 3.4 194 11 190 165 12.7 0 13 12.7 08/18/2006 19:30:00 4.6 0.9 6.8 2.6 4.7 0.8 6.8 2.6 4.6 0.9 6.8 2.3 195 17 192 165 12.7 0 12.7 12.5 08/18/2006 19:40:00 5.2 1.2 8.4 3 5.3 1.1 8.4 3.4 5.3 1.2 8.4 3 188 11 186 165 12.1 0.2 12.5 11.7 08/18/2006 19:50:00 7.9 1.1 10.3 4.2 8 1.1 10.3 4.2 7.9 1.2 11.1 5.3 197 8 187 165 11.7 0.2 11.9 11.4 08/18/2006 20:00:00 8 1.1 11.1 4.9 7.9 1 11.1 4.9 7.8 1.1 10.7 4.9 194 8 192 165 11.4 0.2 11.9 10.9 08/18/2006 20:10:00 7 0.9 9.5 5.3 6.8 0.9 9.1 4.9 6.9 0.9 9.9 4.6 184 7 188 165 11.3 0 11.4 10.9 08/18/2006 20:20:00 6.8 0.9 8.8 4.2 6.7 0.8 8.4 4.6 6.8 0.9 9.1 4.9 187 6 194 165 11.2 0 11.4 10.9 08/18/2006 20:30:00 7.7 0.9 9.9 5.3 7.5 0.8 9.5 5.3 7.6 0.9 9.9 5.7 185 6 187 165 11.1 0 11.4 10.9 08/18/2006 20:40:00 7.9 0.9 9.5 5.3 7.8 0.8 9.1 4.9 7.9 0.9 9.5 4.9 188 6 198 165 10.9 0.1 11.1 10.3 08/18/2006 20:50:00 7.3 0.8 9.1 5.3 7.2 0.8 9.1 4.9 7.4 0.8 9.1 4.2 188 5 194 165 10.7 0.2 10.9 10.3 08/18/2006 21:00:00 7.7 0.7 9.1 5.3 7.7 0.7 9.5 5.7 7.8 0.8 9.5 5.3 191 5 199 165 10.7 0.2 10.9 10.3 08/18/2006 21:10:00 6 0.7 8 3.8 6.2 0.8 8 3.8 6 0.9 7.6 3.4 209 7 208 165 10.9 0 11.1 10.3 08/18/2006 21:20:00 7.2 0.5 8.8 5.7 7.3 0.5 8.4 5.7 7.2 0.7 8.8 4.9 204 3 205 165 10.9 0.2 11.1 10.3 08/18/2006 21:30:00 5.9 0.8 7.6 3.8 5.8 0.9 8 3.8 5.5 1.1 8.4 3 195 6 199 165 10.8 0 11.1 10.3 08/18/2006 21:40:00 4.4 0.6 5.7 2.3 4.3 0.6 5.7 2.3 4.3 0.6 6.1 3 190 9 198 165 10.7 0 10.9 10.6 08/18/2006 21:50:00 5.6 0.5 6.8 4.2 5.7 0.6 6.8 4.2 5.7 0.6 7.2 3.8 197 5 195 165 10.8 0 11.1 10.3 08/18/2006 22:00:00 6.3 0.7 7.6 3.8 6.4 0.7 8 3.8 6.4 0.7 8 3.8 202 4 204 165 10.9 0 11.1 10.3 08/18/2006 22:10:00 5.5 0.8 7.2 3.8 5.6 0.8 7.2 3.8 5.5 0.8 7.6 3.4 207 9 200 165 10.9 0 11.1 10.9 08/18/2006 22:20:00 5.6 0.6 6.8 4.2 5.8 0.6 7.2 4.2 5.4 0.6 6.8 3.8 220 6 219 165 11 0 11.1 10.9 08/18/2006 22:30:00 5.4 0.7 6.8 3 5.5 0.7 6.8 3.4 5.3 0.8 6.8 3 218 7 227 165 11.1 0 11.4 10.9 08/18/2006 22:40:00 5.1 0.6 6.5 2.6 5.2 0.6 6.5 3 4.9 0.6 6.5 3 214 6 216 165 11.1 0 11.4 10.9 08/18/2006 22:50:00 4.5 0.6 6.1 3 4.4 0.6 6.1 2.6 4.2 0.6 6.1 3 202 9 215 165 11.1 0 11.4 10.6 08/18/2006 23:00:00 4.9 0.8 7.2 3 4.8 0.8 6.8 3 5 0.7 6.8 3 191 11 193 165 11 0 11.4 10.9 08/18/2006 23:10:00 4.6 0.6 6.1 3.4 4.5 0.6 6.5 3.4 4.6 0.5 6.1 3.4 198 6 201 165 11 0 11.1 10.6 08/18/2006 23:20:00 5.1 0.7 6.8 3.4 5.1 0.7 6.8 3.4 4.8 0.7 6.5 3 207 6 220 165 11.1 0 11.4 10.6 08/18/2006 23:30:00 4.8 0.9 6.8 3 4.7 0.9 6.8 3 4.9 0.8 7.2 3.4 189 17 196 165 11.1 0 11.4 10.6 08/18/2006 23:40:00 4.6 0.7 6.5 3 4.5 0.7 6.5 2.6 4.6 0.7 6.5 3 195 9 197 165 11.1 0.1 11.4 10.9 08/18/2006 23:50:00 4.8 0.6 6.1 3 4.7 0.6 6.5 2.6 4.7 0.6 6.5 3 200 6 201 165 11.1 0 11.4 10.9 08/19/2006 00:00:00 4.7 0.5 6.1 3.4 4.7 0.5 5.7 3.4 4.8 0.6 6.5 3.4 206 5 217 165 11 0 11.1 10.9 08/19/2006 00:10:00 5 0.6 6.1 3 4.9 0.6 6.1 3 5 0.6 6.5 3.4 191 9 194 165 10.9 0 11.1 10.9 08/19/2006 00:20:00 4.6 0.5 6.1 3.4 4.4 0.5 5.7 3.4 4.7 0.4 6.1 3.8 169 15 190 165 10.7 0 11.1 10.6 08/19/2006 00:30:00 4.9 0.4 5.7 3.4 4.8 0.4 5.7 3.4 5.1 0.4 6.1 4.2 150 5 147 165 10.4 0.1 10.9 10.3 08/19/2006 00:40:00 5.2 0.8 7.2 3.4 5 0.7 6.8 3.4 5.3 0.7 6.8 3.4 165 12 183 165 10.4 0.1 10.9 10.1 08/19/2006 00:50:00 5.6 1 8 2.6 5.4 1 7.6 2.6 5.6 1 8 3.4 177 9 175 165 10.7 0.1 10.9 10.3 08/19/2006 01:00:00 4.8 0.7 6.5 3 4.5 0.6 6.1 2.6 4.6 0.8 6.1 1.9 176 12 175 165 10.6 0 10.9 10.6 08/19/2006 01:10:00 3.7 0.9 6.5 1.9 3.7 0.9 6.1 1.5 4 0.8 5.7 2.3 158 15 167 165 10.6 0 10.9 10.6 08/19/2006 01:20:00 3.5 1 6.1 0.4 3.5 1 6.5 0.4 3.8 0.9 7.2 1.5 155 20 165 165 10.7 0 10.9 10.6 08/19/2006 01:30:00 3.9 0.9 6.1 1.5 3.9 1 6.1 1.5 3.9 1 6.1 1.5 191 17 199 165 10.7 0 10.9 10.6 08/19/2006 01:40:00 5.3 0.4 6.1 4.2 5.2 0.4 6.1 4.2 5.4 0.5 6.5 4.2 200 5 203 165 10.7 0 10.9 10.6 08/19/2006 01:50:00 5.1 0.7 6.5 3.4 5 0.7 6.5 3 5.2 0.7 6.8 3.4 192 5 198 165 10.5 0 10.9 10.3 08/19/2006 02:00:00 4.5 0.3 5.3 3.4 4.3 0.3 4.9 3.4 4.6 0.4 5.3 3.8 186 3 186 165 10.4 0 10.6 10.3 08/19/2006 02:10:00 4.1 0.5 5.3 2.3 3.9 0.5 4.9 2.3 4.2 0.6 4.9 2.6 180 3 180 165 10.5 0 10.9 10.3 08/19/2006 02:20:00 4.8 0.5 5.7 3.4 4.6 0.4 5.3 3.4 4.8 0.4 5.7 3.4 175 5 180 165 10.5 0 10.6 10.3 08/19/2006 02:30:00 3.5 0.5 5.3 2.3 3.3 0.5 4.9 2.3 3.5 0.5 4.9 1.9 165 8 165 165 10.4 0 10.6 10.3 08/19/2006 02:40:00 3.1 0.3 3.8 2.3 2.9 0.3 3.8 2.3 3.1 0.3 3.8 2.3 174 8 163 165 10.5 0 10.9 10.3 08/19/2006 02:50:00 2.3 0.3 3 1.5 2.1 0.4 3 1.1 2.4 0.3 3 1.5 180 10 179 165 10.5 0 10.9 10.3 08/19/2006 03:00:00 1.6 0.3 2.3 1.1 1.6 0.3 2.3 1.1 2.1 0.2 2.6 1.9 186 7 189 165 10.7 0.1 10.9 10.6 08/19/2006 03:10:00 0.6 0.4 1.9 0.4 0.5 0.4 1.9 0.4 0.9 0.5 2.3 0.4 224 32 281 165 10.8 0 11.1 10.6 08/19/2006 03:20:00 0.9 0.5 2.3 0.4 1 0.6 2.6 0.4 0.9 0.5 2.3 0.4 264 15 281 165 11.2 0 11.4 10.9 08/19/2006 03:30:00 0.6 0.3 1.5 0.4 0.5 0.2 1.5 0.4 1.2 0.3 1.9 0.4 170 13 162 165 10.9 0.1 11.1 10.6 08/19/2006 03:40:00 0.5 0.3 1.9 0.4 0.4 0.2 1.5 0.4 0.5 0.3 1.9 0.4 222 33 252 165 11 0.2 11.4 10.6 08/19/2006 03:50:00 0.4 0.2 1.5 0.4 0.4 0.1 1.5 0.4 0.5 0.2 1.5 0.4 213 29 231 165 11.3 0 11.7 11.1 08/19/2006 04:00:00 1 0.6 2.6 0.4 1 0.7 2.3 0.4 1 0.6 2.3 0.4 279 8 285 165 11.3 0 11.7 11.1 08/19/2006 04:10:00 0.5 0.3 1.5 0.4 0.4 0.2 1.5 0.4 0.9 0.5 2.3 0.4 222 35 204 165 11.3 0 11.7 10.9 08/19/2006 04:20:00 0.8 0.5 2.3 0.4 0.7 0.5 2.3 0.4 1.3 0.6 2.3 0.4 268 7 278 165 11.5 0 11.7 11.1 08/19/2006 04:30:00 0.8 0.5 1.9 0.4 0.6 0.5 1.9 0.4 1.4 0.5 2.3 0.4 263 17 275 165 11.4 0 11.7 11.1 08/19/2006 04:40:00 1.6 0.8 3.4 0.4 1.5 1 3.4 0.4 2 0.6 3.8 0.7 239 13 257 165 11.3 0 11.7 10.9 08/19/2006 04:50:00 1.7 0.5 2.6 0.4 1.6 0.5 2.6 0.4 2.2 0.4 3 1.1 205 27 205 165 11.7 0 11.9 11.1 08/19/2006 05:00:00 2.2 0.8 3.4 1.1 2 0.8 3.4 0.7 2.5 0.7 3.8 1.5 195 10 191 165 11.4 0 11.7 11.1 08/19/2006 05:10:00 2.9 0.2 3.4 2.3 2.7 0.2 3.4 2.3 3.2 0.2 3.8 2.6 185 17 205 165 11.4 0 11.9 11.1 08/19/2006 05:20:00 2.7 0.5 3.8 1.5 2.5 0.5 3.4 1.1 2.8 0.6 4.2 1.5 185 13 183 165 11.2 0 11.7 10.9 08/19/2006 05:30:00 2.3 0.5 3.8 1.1 2.2 0.5 4.2 1.1 2.7 0.5 4.6 1.9 193 10 216 165 11.2 0 11.4 10.9 08/19/2006 05:40:00 2.3 0.4 3 1.5 2.2 0.4 3 1.1 2.8 0.4 3.4 1.5 190 10 182 165 11.5 0.1 11.9 11.4 08/19/2006 05:50:00 1.3 0.4 2.3 0.4 1.1 0.4 2.3 0.4 1.8 0.4 2.6 0.7 188 13 181 165 11.5 0 11.7 11.1 08/19/2006 06:00:00 1.4 0.9 3.4 0.4 1.3 0.9 3.4 0.4 1.9 0.8 3.4 0.4 218 30 212 165 11.4 0 11.7 11.1 08/19/2006 06:10:00 2.9 0.7 3.8 1.1 2.8 0.8 4.2 1.1 3 0.8 4.2 1.5 214 12 211 165 11.7 0.1 11.9 11.4 08/19/2006 06:20:00 2.6 0.4 3.4 1.9 2.5 0.4 3.4 1.5 2.9 0.3 3.8 2.3 230 7 232 165 11.8 0 11.9 11.7 08/19/2006 06:30:00 2.3 0.4 3 1.5 2.3 0.4 3 1.5 2.7 0.3 3.4 1.9 224 15 220 165 11.8 0 11.9 11.7 08/19/2006 06:40:00 0.9 0.7 2.3 0.4 0.8 0.7 2.3 0.4 1.7 0.5 3 1.1 213 1 212 165 11.7 0 11.9 11.7 08/19/2006 06:50:00 0.4 0.1 0.7 0.4 0.4 0.1 0.7 0.4 0.8 0.4 1.9 0.4 239 9 225 165 12.3 0.2 12.7 11.7 08/19/2006 07:00:00 0.7 0.3 1.5 0.4 0.5 0.4 1.9 0.4 1 0.5 2.3 0.4 253 11 265 165 12.5 0.3 13.3 11.9 08/19/2006 07:10:00 1.7 0.5 3 0.4 1.6 0.5 3 0.4 1.8 0.4 2.6 0.7 278 10 288 165 13.4 0.1 13.5 13.3 08/19/2006 07:20:00 1.4 0.5 2.6 0.4 1.6 0.6 2.6 0.4 1.9 0.5 2.6 0.4 256 11 253 165 13.8 0.2 14.1 13.3 08/19/2006 07:30:00 1 0.5 2.3 0.4 0.9 0.6 2.3 0.4 1.4 0.6 2.6 0.4 180 64 241 165 14 0 14.1 13.5 08/19/2006 07:40:00 0.6 0.3 1.5 0.4 0.4 0.2 1.5 0.4 0.5 0.3 1.5 0.4 209 79 233 165 14.2 0 14.6 13.8 08/19/2006 07:50:00 0.9 0.5 2.3 0.4 0.7 0.5 2.3 0.4 1 0.6 3 0.4 233 32 251 165 14.6 0 14.9 14.4 08/19/2006 08:00:00 1.1 0.8 3 0.4 0.9 0.8 3 0.4 1.6 0.8 3 0.4 206 26 173 165 14.8 0 15.2 14.6 08/19/2006 08:10:00 1.6 0.8 3.4 0.4 1.4 0.8 3 0.4 1.8 0.8 3.8 0.4 208 27 249 165 14.6 0 14.9 14.4 08/19/2006 08:20:00 1.1 0.8 3 0.4 1.1 0.8 3.4 0.4 1.4 0.8 3.4 0.4 178 64 105 165 13.5 0.4 14.6 13 08/19/2006 08:30:00 1.4 0.6 3.4 0.4 1.6 0.7 3.4 0.4 1.6 0.7 3.4 0.4 246 26 251 165 14.6 0.3 15.2 14.1 08/19/2006 08:40:00 1.2 0.6 2.6 0.4 1.4 0.6 2.6 0.4 1.5 0.6 3 0.4 232 36 179 165 15.2 0 15.7 14.9 08/19/2006 08:50:00 0.6 0.4 1.9 0.4 0.7 0.5 2.3 0.4 0.8 0.5 2.3 0.4 213 58 195 165 15.5 0.3 16.3 15.2 08/19/2006 09:00:00 1.3 1 4.2 0.4 1.4 1 4.2 0.4 1.2 0.8 3.8 0.4 213 56 282 165 15.5 0 15.7 15.2 08/19/2006 09:10:00 2.3 0.9 4.6 0.4 2.6 1 4.9 0.4 2.2 1.2 5.7 0.4 271 56 257 165 15.7 0 16.3 15.5 08/19/2006 09:20:00 1.5 0.9 4.6 0.4 1.9 0.9 4.6 0.4 1.9 0.8 4.2 0.4 227 47 292 165 15.8 0.1 16.3 15.5 08/19/2006 09:30:00 1.3 1 4.2 0.4 1.5 1 4.6 0.4 1.2 0.8 3.4 0.4 214 72 301 165 16.2 0.1 16.8 15.7 08/19/2006 09:40:00 2.4 1.4 4.9 0.4 2.6 1.5 4.9 0.4 2.5 1.4 4.9 0.4 258 58 265 165 16 0.2 16.8 15.5 08/19/2006 09:50:00 1.4 0.7 3 0.4 1.6 0.8 3.4 0.4 1.4 0.7 3 0.4 330 112 282 165 16.3 0 16.6 16 08/19/2006 10:00:00 1.6 0.9 3.4 0.4 1.7 0.9 3.4 0.4 1.6 0.9 3.4 0.4 160 39 175 165 16.1 0 16.3 15.7 08/19/2006 10:10:00 1.3 0.7 3 0.4 1.5 0.6 3 0.4 1.5 0.7 3 0.4 119 56 176 165 16.2 0 16.6 16 08/19/2006 10:20:00 2.4 0.7 3.8 0.4 2.5 0.6 4.2 0.7 2.5 0.7 4.2 0.7 166 13 164 165 16 0.3 16.6 15.2 08/19/2006 10:30:00 3.7 0.7 6.1 1.9 3.7 0.7 5.7 1.9 3.8 0.7 6.5 1.5 163 12 162 165 15.7 0.3 16.3 15.2 08/19/2006 10:40:00 3 0.8 4.9 0.4 3.1 0.8 4.9 0.4 3.2 1 5.3 0.4 168 14 157 165 16.2 0.1 16.8 16 08/19/2006 10:50:00 3.7 0.7 6.1 1.9 3.8 0.7 5.7 1.9 3.8 0.8 5.7 1.9 165 10 162 165 16.1 0 16.6 16 08/19/2006 11:00:00 3.8 0.6 5.3 1.9 3.9 0.6 5.3 2.3 3.9 0.7 5.7 2.6 153 11 153 165 16.5 0.2 16.8 16.3 08/19/2006 11:10:00 3.9 0.5 5.3 1.9 3.9 0.5 4.9 2.3 4.1 0.5 5.3 2.3 159 8 164 165 16.1 0 16.6 15.7 08/19/2006 11:20:00 4.6 0.6 6.5 3 4.7 0.7 6.8 3 4.7 0.6 6.8 3 152 11 147 165 16.6 0.2 17.1 16 08/19/2006 11:30:00 5.2 0.6 6.5 3.8 5.1 0.5 6.8 4.2 5.3 0.6 7.2 3.8 157 6 163 165 16.3 0.1 16.8 16 08/19/2006 11:40:00 5.2 0.4 6.1 3.8 5.1 0.4 6.5 3.8 5.3 0.5 6.5 3.4 157 5 163 165 16.3 0.1 16.6 15.7 08/19/2006 11:50:00 5.3 0.4 6.5 3.8 5.3 0.4 6.5 4.2 5.5 0.5 6.5 4.2 156 5 165 165 16.1 0.2 16.6 15.7 08/19/2006 12:00:00 5.2 0.5 6.8 4.2 5.3 0.5 6.8 4.2 5.4 0.5 7.2 4.2 152 7 158 165 16.6 0.2 17.1 16 08/19/2006 12:10:00 5.1 0.4 6.5 4.2 5.2 0.4 6.8 4.2 5.3 0.4 6.5 4.2 148 7 152 165 17 0.1 17.4 16.6 08/19/2006 12:20:00 4.5 0.7 6.5 3 4.5 0.7 6.5 2.6 4.8 0.7 6.5 3 142 7 143 165 16.8 0 17.1 16.6 08/19/2006 12:30:00 4.8 0.6 6.8 3 4.8 0.6 6.8 3 4.9 0.6 6.8 3 151 8 153 165 16.7 0.1 17.1 16 08/19/2006 12:40:00 5 0.5 6.5 3.8 5 0.5 6.1 3.8 5.2 0.5 6.5 4.2 153 6 149 165 16.9 0.2 17.4 16.3 08/19/2006 12:50:00 4.9 0.5 6.1 3.4 4.9 0.4 6.1 3.4 5.1 0.5 6.1 3.8 151 6 153 165 16 0.1 16.6 15.2 08/19/2006 13:00:00 4.6 0.5 6.1 2.6 4.6 0.5 6.5 3 4.8 0.5 6.8 3.4 148 8 162 165 16.6 0.2 16.8 16.3 08/19/2006 13:10:00 4.8 0.5 6.1 3 4.8 0.5 6.1 3.4 4.9 0.5 6.5 3.8 148 8 152 165 16.2 0.2 16.8 15.7 08/19/2006 13:20:00 4.8 0.5 7.2 3.4 4.8 0.5 6.8 3.8 4.9 0.5 6.1 3.8 140 8 140 165 16.2 0.4 16.8 15.7 08/19/2006 13:30:00 5 0.6 6.8 3.8 5.1 0.6 6.8 3.8 5.2 0.6 7.6 3.4 141 8 150 165 16.9 0 17.1 16.8 08/19/2006 13:40:00 4.5 0.5 6.1 3.4 4.6 0.5 6.1 3.4 4.6 0.5 6.1 3 135 10 130 165 16.4 0.2 16.8 16.3 08/19/2006 13:50:00 3.7 0.8 6.5 1.5 3.9 0.8 6.8 2.3 4 0.8 6.1 2.3 125 10 124 165 16.8 0.1 17.1 16.6 08/19/2006 14:00:00 2.7 1.1 4.9 0.4 3.1 1 5.3 0.7 2.9 1.2 5.7 0.4 125 17 105 165 16.5 0.1 16.8 16.3 08/19/2006 14:10:00 2.2 0.8 4.9 0.4 2.5 0.8 4.9 0.7 2.4 0.8 4.9 0.4 122 13 124 165 16.6 0 16.8 16.3 08/19/2006 14:20:00 2.7 0.7 4.2 0.4 2.9 0.6 4.6 1.1 2.9 0.7 4.2 0.4 117 13 130 165 17.2 0.2 17.7 16.6 08/19/2006 14:30:00 3.3 0.7 5.7 1.5 3.5 0.7 6.1 1.9 3.5 0.7 5.3 2.3 118 11 115 165 16.8 0 17.1 16.6 08/19/2006 14:40:00 2.8 0.5 4.2 1.5 3.1 0.5 4.2 1.9 3 0.6 4.6 1.9 109 12 116 165 16.8 0.1 17.1 16.6 08/19/2006 14:50:00 2 0.5 3 0.4 2.2 0.5 3.4 0.4 2.1 0.5 3 0.4 76 23 80 165 16.6 0 16.8 16.6 08/19/2006 15:00:00 1.5 0.8 3.4 0.4 1.9 0.7 3.4 0.4 1.7 0.7 3.4 0.4 103 27 121 165 16.8 0 17.1 16.6 08/19/2006 15:10:00 1.7 0.8 3.4 0.4 1.9 0.8 3.4 0.4 1.8 0.7 3.4 0.4 61 24 111 165 16.8 0 17.1 16.6 08/19/2006 15:20:00 2 0.6 3.4 0.4 2.2 0.6 3.4 0.4 2.1 0.6 3.4 0.4 32 18 43 165 16.6 0.1 16.8 16.3 08/19/2006 15:30:00 2.1 0.5 3.4 0.4 2.3 0.5 3.4 1.1 2.4 0.5 3.4 1.1 30 11 21 165 16.3 0 16.6 16.3 08/19/2006 15:40:00 1.6 0.5 3 0.4 2 0.5 3.4 0.7 2.1 0.5 3.4 0.4 32 13 29 165 16.6 0.1 16.8 16.3 08/19/2006 15:50:00 1.6 0.4 2.6 0.7 2 0.4 3 1.1 2.1 0.4 3.4 1.1 35 7 32 165 16.1 0 16.6 16 08/19/2006 16:00:00 1 0.5 1.9 0.4 1.4 0.4 2.3 0.4 1.6 0.4 2.3 0.4 30 13 33 165 16.1 0.1 16.8 16 08/19/2006 16:10:00 1.6 0.5 3 0.4 1.8 0.5 3 0.7 2.1 0.4 3 1.1 20 15 15 165 16.6 0 17.1 16.6 08/19/2006 16:20:00 1.7 0.4 2.6 0.4 1.8 0.5 3 0.4 2.3 0.4 3.4 1.5 9 17 21 165 16.4 0 16.8 16.3 08/19/2006 16:30:00 1.6 0.3 2.6 0.7 1.4 0.4 2.6 0.7 2.2 0.3 3.4 1.5 1 8 356 165 16.2 0 16.6 16.3 08/19/2006 16:40:00 2 0.5 3.8 0.7 1.8 0.5 3 0.7 2.5 0.5 3.8 1.5 7 10 2 165 16.1 0 16.6 15.7 08/19/2006 16:50:00 1.9 0.3 2.6 1.1 1.7 0.5 2.6 0.7 2.2 0.3 3 1.5 7 13 353 165 15.5 0.1 16 15.2 08/19/2006 17:00:00 1.4 0.4 2.3 0.4 1.6 0.5 3 0.4 1.6 0.5 3 0.7 6 23 341 165 15.2 0.2 15.7 15.2 08/19/2006 17:10:00 2.3 0.4 3 0.7 2.3 0.5 3.4 0.7 2.8 0.4 3.8 1.9 359 20 331 165 14.8 0.2 15.5 14.6 08/19/2006 17:20:00 2.2 0.4 3.4 1.1 2.2 0.5 3.4 1.1 2.4 0.4 3.4 1.1 13 13 19 165 14.4 0.1 14.9 14.1 08/19/2006 17:30:00 2.1 0.4 3 1.1 2.1 0.5 3.4 1.1 2.3 0.3 3 1.5 12 12 343 165 13.9 0 14.1 13.8 08/19/2006 17:40:00 2.4 0.2 3 1.5 2.3 0.3 3 1.1 2.7 0.3 3.4 1.5 14 3 12 165 13.9 0 14.1 13.8 08/19/2006 17:50:00 2 0.2 2.6 1.5 1.5 0.5 2.6 0.4 2.3 0.2 2.6 1.5 10 5 10 165 14 0 14.1 13.8 08/19/2006 18:00:00 1.7 0.2 2.3 1.1 1.8 0.3 2.3 0.7 2.1 0.3 2.6 1.5 9 4 6 165 14 0 14.1 13.8 08/19/2006 18:10:00 1.1 0.5 1.9 0.4 1.6 0.4 2.3 0.4 1.4 0.5 2.3 0.4 45 28 19 165 13.9 0 14.1 13.8 08/19/2006 18:20:00 0.4 0 0.4 0.4 0.4 0.1 1.1 0.4 0.4 0 0.4 0.4 103 3 165 165 14.1 0 14.4 13.8 08/19/2006 18:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 87 30 165 165 14.3 0 14.6 14.4 08/19/2006 18:40:00 0.4 0 0.7 0.4 0.5 0.3 1.5 0.4 0.6 0.4 1.5 0.4 121 53 165 165 14.1 0.1 14.6 13.8 08/19/2006 18:50:00 0.4 0.2 1.5 0.4 0.5 0.4 1.9 0.4 0.6 0.4 1.5 0.4 172 8 180 165 13.5 0 13.8 13.3 08/19/2006 19:00:00 0.5 0.2 1.1 0.4 0.8 0.4 1.5 0.4 1 0.4 1.5 0.4 166 4 164 165 13.3 0 13.5 13 08/19/2006 19:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 164 0 165 165 13.3 0 13.3 13 08/19/2006 19:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 164 0 165 165 13.4 0 13.5 13.3 08/19/2006 19:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 164 0 165 165 13.3 0 13.5 13.3 08/19/2006 19:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 164 0 165 165 13.3 0 13.3 13 08/19/2006 19:50:00 0.4 0 0.7 0.4 0.4 0.1 1.1 0.4 0.4 0 0.4 0.4 106 56 85 165 13 0.1 13.3 12.7 08/19/2006 20:00:00 0.6 0.3 1.5 0.4 0.8 0.5 1.9 0.4 0.8 0.5 1.9 0.4 112 1 112 165 12.7 0 13 12.5 08/19/2006 20:10:00 0.9 0.4 2.3 0.4 1.2 0.4 2.6 0.4 0.9 0.5 1.9 0.4 133 19 144 165 12.3 0.1 12.7 11.9 08/19/2006 20:20:00 1.9 0.4 3 1.1 2.2 0.4 3 1.5 2.1 0.4 3 1.1 113 13 122 165 11.9 0 12.2 11.7 08/19/2006 20:30:00 0.5 0.2 1.5 0.4 0.6 0.4 1.9 0.4 1 0.6 2.3 0.4 93 1 94 165 12.3 0.1 12.5 11.9 08/19/2006 20:40:00 1.1 0.4 1.9 0.4 1.1 0.5 2.3 0.4 1.6 0.4 2.3 0.4 2 26 0 165 12.3 0.2 12.7 11.9 08/19/2006 20:50:00 0.9 0.6 2.3 0.4 0.9 0.7 2.6 0.4 1.3 0.8 2.6 0.4 352 3 342 165 11.8 0 11.9 11.4 08/19/2006 21:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.5 0.2 1.1 0.4 353 1 165 165 11.7 0 11.9 11.7 08/19/2006 21:10:00 0.4 0 0.7 0.4 0.4 0.1 0.7 0.4 0.4 0.1 1.1 0.4 118 107 208 165 11.7 0 11.9 11.7 08/19/2006 21:20:00 0.5 0.3 1.5 0.4 0.7 0.4 1.5 0.4 0.8 0.5 1.9 0.4 147 29 112 165 11.8 0 11.9 11.7 08/19/2006 21:30:00 1.9 1 3.4 0.4 2.1 1 3.8 0.4 2.2 1 3.8 0.4 148 9 151 165 11.6 0 11.9 11.4 08/19/2006 21:40:00 3 0.6 4.2 1.9 3.1 0.6 4.2 1.9 3.3 0.5 4.2 2.3 144 6 145 165 11.1 0 11.4 10.9 08/19/2006 21:50:00 2.4 0.5 3.4 1.5 2.6 0.5 3.4 1.5 2.8 0.4 3.8 1.9 152 6 157 165 10.8 0.1 11.1 10.6 08/19/2006 22:00:00 4.1 0.8 5.7 2.3 4.1 0.8 5.7 2.6 4.4 0.8 6.1 2.6 162 4 164 165 10.5 0 10.9 10.3 08/19/2006 22:10:00 5.6 0.9 7.2 3.8 5.5 0.8 6.8 4.2 5.8 0.8 7.6 4.2 171 7 176 165 10.3 0 10.6 9.8 08/19/2006 22:20:00 5.9 0.5 7.2 4.6 5.8 0.4 6.8 4.6 6.1 0.5 7.2 4.9 174 5 179 165 10.2 0.1 10.6 9.6 08/19/2006 22:30:00 5.1 0.5 6.1 3.8 5.1 0.4 6.1 3.8 5.4 0.6 6.8 3.8 176 7 178 165 10.1 0.1 10.3 9.6 08/19/2006 22:40:00 4.1 0.7 5.7 2.3 4.1 0.6 5.7 2.6 4.5 0.6 5.7 3 178 4 174 165 10.1 0.1 10.3 9.6 08/19/2006 22:50:00 3.4 0.4 4.2 2.6 3.5 0.4 4.2 2.6 3.8 0.5 4.9 2.6 171 10 169 165 10.1 0.1 10.3 9.8 08/19/2006 23:00:00 3.9 0.8 5.7 2.6 4 0.7 5.3 2.6 4.3 0.7 6.1 2.6 169 8 165 165 10.1 0.1 10.6 9.6 08/19/2006 23:10:00 5 0.3 5.7 4.2 5 0.3 5.7 4.2 5.3 0.4 6.5 4.2 170 4 167 165 10.1 0.2 10.3 9.6 08/19/2006 23:20:00 4.7 0.3 5.3 3.4 4.7 0.3 5.3 3.8 5.1 0.4 6.1 4.2 174 5 173 165 10.1 0 10.3 9.8 08/19/2006 23:30:00 4.5 0.3 5.3 3.8 4.5 0.3 5.3 3.8 4.8 0.3 5.7 4.2 163 4 160 165 10.1 0 10.3 9.8 08/19/2006 23:40:00 4.5 0.3 5.3 3.8 4.4 0.3 5.3 3.8 4.8 0.4 6.1 3.8 164 10 165 165 10 0 10.3 9.6 08/19/2006 23:50:00 5.4 0.5 6.8 4.2 5.4 0.5 6.5 4.2 5.7 0.5 6.8 4.9 160 5 148 165 9.9 0 10.1 9.6 08/20/2006 00:00:00 7.2 0.5 8.4 6.1 7.1 0.5 8.4 5.7 7.4 0.4 8.4 6.5 155 3 154 165 10 0 10.3 9.6 08/20/2006 00:10:00 7.5 0.5 8.8 5.7 7.4 0.6 8.4 5.7 7.8 0.5 8.8 6.1 158 3 153 165 10.1 0 10.3 9.8 08/20/2006 00:20:00 5.6 0.5 6.8 4.6 5.6 0.5 6.8 4.6 5.9 0.5 7.2 4.6 158 5 160 165 10.1 0 10.3 10.1 08/20/2006 00:30:00 5.2 0.6 6.5 3.8 5.2 0.6 6.5 3.8 5.5 0.5 6.8 4.2 156 5 161 165 10.2 0 10.3 9.8 08/20/2006 00:40:00 4.3 0.3 4.9 3.8 4.3 0.3 4.9 3.4 4.6 0.3 5.7 3.8 155 4 157 165 10.2 0 10.6 9.8 08/20/2006 00:50:00 5.8 0.6 6.8 4.6 5.7 0.5 6.8 4.6 6 0.5 7.2 4.9 155 3 159 165 10.3 0 10.6 10.3 08/20/2006 01:00:00 5.3 1 6.8 3.4 5.1 0.9 6.8 3.4 5.3 0.9 6.8 3.4 162 8 156 165 10.3 0 10.6 9.8 08/20/2006 01:10:00 3.7 0.5 6.1 3 3.6 0.5 5.7 2.6 3.8 0.3 4.9 3 168 8 187 165 10.2 0 10.6 9.8 08/20/2006 01:20:00 3.5 0.8 6.1 1.5 3.4 0.8 5.7 1.5 3.7 0.8 5.7 2.3 164 13 158 165 10.2 0 10.6 9.6 08/20/2006 01:30:00 3.1 0.7 4.9 1.1 3.1 0.7 4.9 1.1 3.2 0.7 4.9 1.1 191 13 169 165 10.4 0 10.6 9.8 08/20/2006 01:40:00 3.1 0.5 4.6 1.9 3.1 0.5 4.6 1.5 3.2 0.4 4.2 1.9 183 8 199 165 10.3 0 10.6 9.8 08/20/2006 01:50:00 5 1.7 8 2.3 5.1 1.7 8.4 2.3 4.7 1.7 8.4 2.3 203 9 200 165 10.5 0 10.9 10.1 08/20/2006 02:00:00 7.2 1.1 9.1 4.6 7.2 1.1 9.1 4.6 7.3 1.3 9.9 4.2 193 10 195 165 10.7 0 10.9 10.3 08/20/2006 02:10:00 7.1 1 9.9 4.9 7.1 1 9.5 4.9 7 1 9.1 5.3 199 7 206 165 10.7 0 10.9 10.6 08/20/2006 02:20:00 6.2 0.8 8 4.6 6.3 0.9 8.4 4.6 6.2 0.9 8.4 4.2 198 5 193 165 10.7 0 10.9 10.3 08/20/2006 02:30:00 5.8 0.7 8 3.4 5.8 0.7 8 3.8 5.8 0.7 7.6 3.4 198 7 205 165 10.7 0 10.9 10.3 08/20/2006 02:40:00 6.4 0.6 7.6 4.6 6.3 0.5 7.6 4.9 6.4 0.6 7.6 4.9 192 5 186 165 10.7 0 10.9 10.3 08/20/2006 02:50:00 5.4 1 7.2 3 5.4 1 7.2 3.4 5.6 1 7.2 3 180 10 186 165 10.7 0 10.9 10.3 08/20/2006 03:00:00 3.6 0.6 5.3 2.3 3.5 0.6 5.3 2.3 3.4 0.6 4.9 2.3 184 10 165 165 10.7 0.1 10.9 10.3 08/20/2006 03:10:00 3.1 0.7 4.6 1.5 3 0.6 4.6 1.5 3 0.5 4.6 1.9 187 11 190 165 10.7 0 10.9 10.3 08/20/2006 03:20:00 2.8 0.8 4.6 1.1 2.9 0.8 4.6 1.1 3 0.6 4.9 1.1 207 11 217 165 10.7 0 10.9 10.3 08/20/2006 03:30:00 3 0.9 4.9 1.5 3 0.9 4.9 1.1 3.2 0.8 4.6 1.9 186 11 204 165 10.7 0.1 10.9 10.3 08/20/2006 03:40:00 2.5 0.4 3 1.5 2.5 0.4 3 1.1 2.8 0.3 3.8 1.5 164 6 169 165 10.7 0.1 10.9 10.1 08/20/2006 03:50:00 2.2 0.5 3.4 0.7 2.1 0.5 3.4 0.4 2.4 0.5 3.4 1.1 167 10 165 165 10.7 0.1 10.9 10.1 08/20/2006 04:00:00 0.6 0.3 1.5 0.4 0.5 0.3 1.5 0.4 1.2 0.4 1.9 0.4 178 4 166 165 10.7 0.2 10.9 10.3 08/20/2006 04:10:00 0.8 0.3 1.5 0.4 0.8 0.3 1.5 0.4 0.9 0.4 1.9 0.4 225 22 214 165 10.7 0.2 10.9 10.3 08/20/2006 04:20:00 0.9 0.4 1.9 0.4 0.7 0.5 1.9 0.4 1.2 0.5 1.9 0.4 302 16 323 165 10.7 0.1 10.9 10.3 08/20/2006 04:30:00 1.8 0.5 2.6 0.7 1.9 0.5 2.6 0.7 2.1 0.5 3 1.1 316 6 322 165 10.7 0.1 10.9 10.1 08/20/2006 04:40:00 2.4 0.3 3 1.9 2.4 0.2 3 1.9 2.7 0.2 3 2.3 328 5 334 165 10.7 0.1 10.9 10.1 08/20/2006 04:50:00 2.6 0.3 3.4 1.5 2.6 0.3 3.4 1.9 2.8 0.3 3.4 1.9 317 8 328 165 10.7 0.1 10.9 10.1 08/20/2006 05:00:00 1.8 0.4 2.6 1.1 1.8 0.5 2.6 0.4 2.2 0.3 2.6 1.5 331 8 328 165 10.7 0.1 10.9 10.3 08/20/2006 05:10:00 0.7 0.4 1.5 0.4 0.5 0.3 1.5 0.4 1.3 0.3 2.3 0.7 350 8 350 165 10.7 0 10.9 10.3 08/20/2006 05:20:00 1.2 0.4 2.3 0.4 1.1 0.5 2.3 0.4 1.5 0.3 2.3 0.7 320 14 289 165 10.7 0 10.9 10.3 08/20/2006 05:30:00 2 0.5 3.4 1.1 2.2 0.5 3.4 1.5 1.9 0.7 3.8 0.7 282 9 277 165 10.7 0 10.9 10.6 08/20/2006 05:40:00 2.8 0.8 4.6 1.1 3 0.8 4.6 1.5 2.7 0.8 4.6 1.1 281 9 284 165 10.7 0 10.9 10.6 08/20/2006 05:50:00 3.5 0.4 4.2 2.6 3.6 0.4 4.6 2.6 3.6 0.4 4.6 2.3 288 5 297 165 10.7 0 10.9 10.6 08/20/2006 06:00:00 3.8 0.5 4.6 2.6 3.8 0.5 4.9 2.6 3.5 0.5 4.6 1.9 291 4 295 165 10.8 0 11.1 10.6 08/20/2006 06:10:00 3.1 0.4 4.2 1.9 3.1 0.4 4.2 1.9 2.7 0.5 4.2 1.9 299 7 286 165 10.9 0 11.1 10.3 08/20/2006 06:20:00 3 0.5 4.2 1.9 3.1 0.5 4.2 1.9 3 0.5 4.6 1.9 312 6 309 165 10.9 0 11.1 10.6 08/20/2006 06:30:00 2.2 0.6 3.4 0.7 2.3 0.6 3.4 1.1 2.3 0.5 3.4 1.1 294 12 302 165 10.9 0 11.1 10.6 08/20/2006 06:40:00 2.1 0.4 3 1.5 2.3 0.4 3 1.5 1.9 0.4 3 0.7 290 6 287 165 11 0 11.4 10.6 08/20/2006 06:50:00 2.7 0.5 3.8 1.5 2.8 0.5 3.8 1.5 2.3 0.4 3 0.7 301 7 296 165 11 0 11.1 10.6 08/20/2006 07:00:00 2.6 0.4 3.8 1.5 2.8 0.4 3.8 1.5 2.2 0.4 3 1.5 301 5 304 165 10.9 0 11.1 10.6 08/20/2006 07:10:00 3.5 0.5 4.9 2.3 3.5 0.5 4.6 2.3 3.1 0.5 4.2 1.9 307 6 307 165 10.9 0 11.1 10.3 08/20/2006 07:20:00 4.9 0.7 6.5 3 4.9 0.7 6.5 3 4.1 1 6.1 1.9 294 8 291 165 11 0 11.1 10.6 08/20/2006 07:30:00 5.7 0.5 7.2 4.2 5.7 0.5 7.6 4.6 5.2 0.7 7.6 3.4 292 6 282 165 10.9 0 11.1 10.6 08/20/2006 07:40:00 4.9 0.5 6.5 3.4 4.9 0.5 6.5 3.8 4.1 0.6 6.1 2.6 295 5 298 165 10.9 0 11.1 10.3 08/20/2006 07:50:00 5.3 0.5 6.5 4.2 5.4 0.5 6.5 4.2 4.5 0.7 6.5 3 295 5 291 165 10.7 0 11.1 10.3 08/20/2006 08:00:00 5.8 0.7 7.6 4.2 5.7 0.7 7.6 4.2 4.5 0.8 7.6 2.6 296 5 286 165 10.8 0 11.1 10.6 08/20/2006 08:10:00 5.5 0.6 7.2 3.8 5.4 0.6 6.8 4.2 4.3 0.6 6.1 3 300 8 298 165 10.9 0 11.1 10.3 08/20/2006 08:20:00 5.6 0.6 7.6 3.8 5.6 0.6 7.2 4.2 4.5 0.6 6.5 3 299 8 305 165 11.1 0 11.4 10.9 08/20/2006 08:30:00 5.6 0.6 7.6 4.2 5.6 0.6 7.6 4.2 4.6 0.6 6.5 3 297 8 287 165 11 0 11.1 10.6 08/20/2006 08:40:00 5.6 0.6 7.2 3.8 5.6 0.7 7.2 4.2 4.7 0.8 6.8 2.6 292 8 268 165 11 0 11.1 10.9 08/20/2006 08:50:00 5.2 0.8 8 3.8 5.2 0.7 8 3.8 4.6 0.7 6.5 2.6 293 8 302 165 11 0 11.1 10.6 08/20/2006 09:00:00 4.6 0.5 6.1 3.4 4.7 0.5 6.5 3.4 4.5 0.7 6.1 2.6 288 8 277 165 11 0 11.1 10.6 08/20/2006 09:10:00 5.4 0.8 7.6 3.8 5.4 0.8 7.6 3.8 4.6 1 7.2 3 301 8 307 165 11 0 11.1 10.6 08/20/2006 09:20:00 6.8 1.1 9.9 4.6 6.7 1 9.5 4.6 6.1 1 8.8 3.4 313 8 302 165 11.1 0 11.1 10.9 08/20/2006 09:30:00 6.4 1 9.5 4.2 6.3 1 9.5 4.2 5.6 1 8 3.4 312 9 300 165 11.1 0 11.4 10.6 08/20/2006 09:40:00 8.6 1 11.1 5.7 8.5 1.1 11.1 5.7 7.3 1 9.5 4.6 309 7 313 165 11 0 11.4 10.9 08/20/2006 09:50:00 8.9 1.1 11.8 5.7 8.8 1.1 11.5 6.5 7.3 1 10.3 4.9 307 7 301 165 10.9 0 11.1 10.9 08/20/2006 10:00:00 6.7 1.3 9.5 3.4 6.6 1.2 9.1 3.4 5.7 1.2 9.5 3.4 303 12 311 165 10.9 0 11.1 10.9 08/20/2006 10:10:00 7.6 1.6 11.5 4.6 7.5 1.6 11.5 4.6 6.4 1.4 9.5 3 306 8 298 165 11 0 11.1 10.9 08/20/2006 10:20:00 10.1 1.2 12.6 6.8 9.9 1.2 12.2 6.8 9.2 1.3 11.8 4.9 314 6 314 165 10.8 0.1 11.1 10.9 08/20/2006 10:30:00 10.3 1 12.6 7.6 10.2 1 12.6 7.6 9.1 1.2 11.8 6.1 310 6 310 165 10.7 0.1 10.9 10.3 08/20/2006 10:40:00 9.6 1 12.2 6.8 9.5 1 12.2 7.2 8.6 1.2 11.8 6.1 311 7 310 165 10.7 0.1 10.9 10.3 08/20/2006 10:50:00 8.6 1.6 13.3 4.9 8.5 1.6 13 4.9 8.3 1.6 13.3 4.9 320 11 309 165 10.8 0 11.1 10.6 08/20/2006 11:00:00 9.6 1.5 12.6 6.1 9.4 1.5 12.2 6.1 8.5 1.5 12.2 4.2 313 8 318 165 10.9 0 11.1 10.6 08/20/2006 11:10:00 9.5 1.1 12.6 6.5 9.4 1.1 12.2 6.5 7.9 1 11.1 5.7 307 7 315 165 11.1 0 11.4 10.9 08/20/2006 11:20:00 9.1 1.2 12.2 6.1 8.9 1.2 12.2 5.7 7.9 1.2 11.1 4.6 309 6 300 165 11.2 0 11.4 11.1 08/20/2006 11:30:00 8.5 1 11.8 6.1 8.4 0.9 11.5 6.1 7 1.1 10.7 4.6 305 7 304 165 11.5 0.2 11.9 10.9 08/20/2006 11:40:00 8.4 1.2 11.5 5.3 8.2 1.1 11.5 4.9 7.5 1.3 11.5 4.6 311 8 308 165 11.6 0.1 11.9 11.1 08/20/2006 11:50:00 8.3 1.4 12.2 5.3 8.2 1.3 11.8 5.3 6.9 1.3 11.5 4.2 307 8 304 165 11.8 0.1 12.2 11.4 08/20/2006 12:00:00 10.2 1 12.6 7.2 10 1 12.2 7.2 8.8 1.1 11.5 5.7 308 6 302 165 11.9 0 12.2 11.7 08/20/2006 12:10:00 9.7 1.1 12.2 5.7 9.6 1.1 12.2 4.9 8.6 1.1 11.8 4.9 309 6 310 165 12.2 0 12.5 11.9 08/20/2006 12:20:00 9.9 1.5 13.7 6.1 9.8 1.5 13.7 6.5 8.7 1.3 11.8 5.7 310 7 304 165 12.5 0 12.7 12.2 08/20/2006 12:30:00 10.7 1.1 13.3 7.2 10.6 1.1 13.3 6.5 9.3 1.4 13 5.7 309 7 300 165 12.4 0 12.7 12.5 08/20/2006 12:40:00 10.2 1.2 13.7 6.8 10.2 1.2 13.7 6.8 8.6 1.3 13 5.3 306 6 298 165 12.3 0 12.5 12.2 08/20/2006 12:50:00 11.1 1.1 14.1 8.4 11.1 1.1 14.1 8.4 8.5 1 11.8 5.7 302 5 304 165 11.9 0.1 12.2 11.4 08/20/2006 13:00:00 10.9 1.3 13.3 7.6 10.9 1.3 13.7 7.6 8.7 1 11.5 5.7 305 6 296 165 12.1 0 12.5 11.9 08/20/2006 13:10:00 10.4 1.1 13.3 8 10.3 1.1 13.3 7.6 8.6 1.1 11.1 5.7 306 7 307 165 12.6 0 13 11.9 08/20/2006 13:20:00 11.3 1.1 13.7 7.6 11.2 1.1 13.3 7.6 10 1.3 13.3 6.8 311 8 297 165 12.5 0.1 12.7 11.9 08/20/2006 13:30:00 10.5 1 13 7.6 10.5 1 12.6 7.6 8.8 1.2 11.8 6.5 306 6 302 165 12.5 0 12.7 11.9 08/20/2006 13:40:00 10.6 1.1 15.6 7.6 10.6 1 15.3 7.6 8.4 1.1 13.3 6.1 303 5 292 165 12.7 0 13 12.5 08/20/2006 13:50:00 10.1 1.1 13.3 7.2 10.1 1.1 13 7.2 8.5 0.8 10.7 6.8 309 8 302 165 12.9 0.1 13.3 12.7 08/20/2006 14:00:00 10.9 1 13.3 8 10.9 1 13.3 8 9.4 1.1 12.6 7.2 308 6 295 165 12.9 0.1 13 12.7 08/20/2006 14:10:00 10.8 1 13.3 8.4 10.8 1 13.3 8.4 9 1.2 11.8 6.1 305 6 309 165 12.9 0 13 12.7 08/20/2006 14:20:00 9.1 1.2 12.2 5.7 9.1 1.2 11.8 6.1 8.2 1.1 11.5 5.3 311 11 293 165 13.2 0 13.5 12.7 08/20/2006 14:30:00 8.8 1.1 12.2 5.7 8.8 1.1 11.5 6.1 7.8 1.1 12.2 4.6 309 9 313 165 13.3 0 13.5 13.3 08/20/2006 14:40:00 8.5 1 11.5 6.1 8.4 1 11.1 5.3 6.9 1.1 9.9 4.2 305 7 298 165 13.9 0.4 14.9 13.3 08/20/2006 14:50:00 7.3 1.3 10.7 4.6 7.3 1.3 10.7 4.6 6.6 0.9 9.1 4.2 318 14 304 165 14.5 0.3 14.9 13.8 08/20/2006 15:00:00 6.1 1.2 9.9 3 6.1 1.2 9.9 3.4 5.4 1.2 8.4 2.6 322 18 294 165 14.8 0.7 16 14.1 08/20/2006 15:10:00 5.6 1.2 8.4 2.6 5.5 1.2 8.4 1.9 5.1 1.1 8 2.3 320 15 302 165 15.9 0.1 16.3 15.5 08/20/2006 15:20:00 4.7 1.2 7.6 1.1 4.6 1.3 8 0.7 3.9 1.3 8.4 0.4 313 17 302 165 15.9 0.2 16.3 15.7 08/20/2006 15:30:00 5.8 1.7 11.1 1.1 5.7 1.7 10.7 0.7 4.8 1.4 9.5 1.1 307 22 293 165 16.6 0.2 17.4 16.3 08/20/2006 15:40:00 6.6 1.1 9.9 3 6.6 1.1 9.9 3 5.2 1.2 9.1 1.5 300 12 265 165 16.8 0 17.4 16.6 08/20/2006 15:50:00 6.1 1 9.1 4.2 5.9 1.1 9.5 3.4 5.3 1 8.8 2.6 324 19 311 165 17.3 0.2 17.7 16.8 08/20/2006 16:00:00 5.7 1.1 8.8 2.3 5.7 1.1 8.4 2.3 5 1.1 8.4 2.6 313 16 300 165 16.7 0.3 17.1 16.3 08/20/2006 16:10:00 7.7 1.5 11.1 4.2 7.6 1.5 10.7 3.8 6.4 1.3 10.3 3.4 306 11 284 165 15.9 0.6 16.8 14.9 08/20/2006 16:20:00 9.6 1 12.6 7.2 9.5 1 12.2 6.8 7.7 1.2 11.1 5.3 299 7 293 165 15.2 0 15.7 15.2 08/20/2006 16:30:00 8.4 1.3 11.5 4.9 8.4 1.2 11.5 5.3 6.9 1.1 9.9 4.6 301 7 292 165 15.6 0.2 16 15.2 08/20/2006 16:40:00 7 1.4 11.5 3.8 6.9 1.4 11.8 3.8 5.9 1.1 11.8 3.4 300 10 292 165 15.7 0.2 16.3 15.2 08/20/2006 16:50:00 8.5 1.4 11.5 5.3 8.6 1.3 11.5 5.3 6.7 1.1 10.7 3.8 298 6 298 165 15.3 0.1 15.7 14.9 08/20/2006 17:00:00 9.6 1 11.8 6.8 9.6 1 11.8 7.2 7.4 1 10.3 4.9 303 6 298 165 14.8 0 15.5 14.6 08/20/2006 17:10:00 9.4 1 12.2 6.8 9.4 1 12.2 6.8 7.8 1 10.3 5.3 306 6 298 165 14.8 0 15.2 14.6 08/20/2006 17:20:00 7 1 9.9 4.6 7 1 9.5 4.9 6.1 1 9.1 3.8 312 11 304 165 15.5 0.3 16.3 14.9 08/20/2006 17:30:00 7.7 1 9.9 4.9 7.6 1 9.9 4.9 6.7 1 9.1 4.2 308 7 297 165 15.4 0.2 16 15.2 08/20/2006 17:40:00 7.2 1.2 10.3 3.8 7.2 1.1 10.3 4.2 6.1 1.1 10.3 3.4 305 11 304 165 15.3 0 15.7 15.2 08/20/2006 17:50:00 7.3 1.2 9.9 4.2 7.3 1.2 10.3 4.6 6.7 1 9.5 4.2 311 9 296 165 15.5 0 15.7 15.2 08/20/2006 18:00:00 8.3 1.1 11.8 4.9 8.2 1.2 11.5 4.9 7.5 1.1 11.1 4.9 311 6 304 165 15.1 0.1 15.7 14.9 08/20/2006 18:10:00 8.2 0.8 10.3 5.7 8.2 0.8 10.3 5.7 7.4 0.9 9.5 4.6 312 8 304 165 14.9 0.1 15.2 14.6 08/20/2006 18:20:00 8.9 0.6 10.3 7.2 8.8 0.6 10.3 7.2 7.9 0.7 9.5 6.1 312 5 307 165 14.6 0 15.2 14.4 08/20/2006 18:30:00 8.1 1 10.3 5.7 8 1 10.3 5.3 7.3 0.8 9.5 4.9 313 7 305 165 14.6 0.1 14.9 14.4 08/20/2006 18:40:00 7 0.9 9.1 4.2 7.1 0.8 8.8 4.6 6.6 0.9 9.1 4.2 317 9 319 165 15 0 15.2 14.9 08/20/2006 18:50:00 8 1 9.9 4.9 8 1 9.9 5.3 7.3 1.2 9.5 4.2 313 7 318 165 14.4 0.4 15.2 13.5 08/20/2006 19:00:00 7.8 0.6 9.5 6.5 7.6 0.6 9.1 6.1 7.4 0.6 9.5 5.7 317 7 320 165 13.7 0 13.8 13.5 08/20/2006 19:10:00 6.4 0.8 8.8 4.2 6.2 0.8 8.8 3.8 6.2 0.8 8 4.2 316 7 317 165 13.5 0.1 13.8 13 08/20/2006 19:20:00 6 0.9 8 3.8 6.2 0.8 8 4.2 5.5 0.7 7.2 3.4 310 8 316 165 13.3 0 13.8 12.7 08/20/2006 19:30:00 6.2 0.8 8.8 4.6 6.2 0.7 8.4 4.6 5.8 0.8 8.4 3.8 313 7 325 165 13.1 0 13.3 12.5 08/20/2006 19:40:00 6.6 0.7 8.8 4.6 6.6 0.7 8.4 4.9 6.3 0.8 8.4 4.2 313 6 315 165 12.9 0 13 12.7 08/20/2006 19:50:00 8.1 0.6 9.5 6.5 8 0.5 9.5 6.5 7.8 0.6 9.1 5.7 315 5 312 165 12.5 0.1 12.7 12.5 08/20/2006 20:00:00 7.9 0.6 9.1 6.5 7.8 0.6 9.5 6.5 7.8 0.5 9.1 6.5 317 4 314 165 12.3 0 12.5 12.2 08/20/2006 20:10:00 7.7 0.7 9.1 5.7 7.7 0.7 9.1 5.3 7.6 0.7 9.1 5.3 318 5 319 165 12.2 0.1 12.5 11.9 08/20/2006 20:20:00 7.1 0.6 8.8 5.7 7.1 0.6 8.4 5.7 6.9 0.6 8.8 5.3 316 5 319 165 12.3 0.1 12.5 11.9 08/20/2006 20:30:00 6.5 0.6 8 4.9 6.5 0.6 8 4.9 6.3 0.6 7.6 4.6 318 8 320 165 12.3 0 12.5 11.9 08/20/2006 20:40:00 5.9 0.6 7.6 4.6 5.9 0.5 7.2 4.6 5.9 0.5 7.2 4.6 320 6 335 165 11.9 0.1 12.2 11.4 08/20/2006 20:50:00 5.7 0.5 7.2 4.2 5.7 0.5 6.8 4.2 5.5 0.6 6.8 4.2 315 6 312 165 11.7 0.2 12.2 11.1 08/20/2006 21:00:00 6.4 0.5 8.4 5.3 6.4 0.5 8 5.3 5 0.6 6.5 3.4 304 4 305 165 11.8 0.2 12.2 11.4 08/20/2006 21:10:00 7.4 0.7 9.5 5.7 7.4 0.7 9.1 5.7 5.7 0.7 7.6 4.2 304 4 302 165 12 0.2 12.5 11.4 08/20/2006 21:20:00 6.9 0.6 8.4 5.7 6.9 0.6 8.4 5.3 5 0.6 6.8 3.4 299 4 293 165 12.1 0.2 12.5 11.7 08/20/2006 21:30:00 6.6 0.4 7.6 5.7 6.7 0.4 7.6 5.7 4.9 0.5 6.5 3.4 297 3 293 165 11.9 0.2 12.2 11.4 08/20/2006 21:40:00 7.6 0.4 8.8 6.1 7.6 0.4 8.8 6.1 5.6 0.5 6.8 4.2 303 3 300 165 11.9 0 11.9 11.4 08/20/2006 21:50:00 8.2 0.4 9.1 6.8 8.2 0.5 9.1 6.5 6.7 0.7 8.4 4.6 307 3 310 165 11.9 0 11.9 11.7 08/20/2006 22:00:00 8.1 0.4 9.1 6.8 8 0.5 9.1 6.5 6.9 0.6 8.4 5.3 308 3 308 165 11.8 0 11.9 11.7 08/20/2006 22:10:00 8.3 0.4 9.1 7.2 8.2 0.4 9.1 7.2 6.7 0.7 8.4 4.9 307 3 312 165 11.8 0 11.9 11.7 08/20/2006 22:20:00 8.7 0.4 9.9 7.6 8.7 0.4 10.3 7.6 7 0.8 9.1 4.9 306 3 309 165 11.8 0 11.9 11.7 08/20/2006 22:30:00 8.2 0.3 9.1 7.2 8.2 0.4 9.1 7.2 6.3 0.5 7.6 4.9 305 2 303 165 11.9 0 11.9 11.7 08/20/2006 22:40:00 8 0.2 8.4 6.8 8 0.3 8.4 6.8 6.4 0.6 8 4.6 306 2 292 165 11.9 0 12.2 11.7 08/20/2006 22:50:00 7.9 0.4 8.8 6.8 7.8 0.4 8.8 6.8 6.2 0.5 7.6 4.6 306 2 307 165 11.9 0 12.2 11.7 08/20/2006 23:00:00 7.9 0.4 8.8 6.8 7.8 0.4 8.8 6.8 6.4 0.5 7.6 4.9 307 2 307 165 12 0 12.2 11.7 08/20/2006 23:10:00 7.6 0.3 8.4 6.5 7.5 0.3 8 6.5 6.4 0.6 7.6 4.9 308 3 310 165 11.9 0 12.2 11.7 08/20/2006 23:20:00 6.9 0.3 7.6 6.1 6.8 0.3 7.6 6.1 5.7 0.6 7.2 4.2 307 3 311 165 11.9 0.1 12.2 11.4 08/20/2006 23:30:00 5.7 0.3 6.5 4.9 5.7 0.3 6.5 4.9 4.7 0.4 5.7 3.4 305 3 301 165 11.9 0 12.2 11.4 08/20/2006 23:40:00 5.8 0.3 6.8 4.9 5.8 0.3 6.8 4.9 5.2 0.5 7.2 3.8 309 3 304 165 11.8 0.2 12.2 11.1 08/20/2006 23:50:00 6.2 0.3 6.8 5.3 6.2 0.4 6.8 4.9 5.1 0.6 6.5 3.8 305 5 302 165 11.7 0.1 11.9 11.1 08/21/2006 00:00:00 6 0.3 6.8 5.3 5.9 0.3 6.8 5.3 5.3 0.6 6.5 3.8 308 3 309 165 11.7 0 11.9 11.1 08/21/2006 00:10:00 5.7 0.3 6.5 4.9 5.8 0.3 6.5 4.9 4.4 0.5 5.7 3.4 304 3 304 165 11.7 0.1 11.9 11.1 08/21/2006 00:20:00 5.7 0.3 6.8 4.9 5.7 0.3 6.8 4.9 4.4 0.4 5.3 3.4 304 2 307 165 11.7 0.1 11.9 11.1 08/21/2006 00:30:00 5.7 0.2 6.5 4.9 5.6 0.2 6.1 4.9 4.7 0.4 5.7 3.8 307 3 306 165 11.7 0.1 11.9 10.9 08/21/2006 00:40:00 6.5 0.5 7.6 5.3 6.5 0.5 7.6 5.3 5.4 0.6 6.8 4.2 308 2 309 165 11.3 0.1 11.7 10.9 08/21/2006 00:50:00 7.6 0.6 9.5 6.5 7.5 0.6 9.5 6.5 5.9 0.7 8.8 4.6 305 4 302 165 11.3 0 11.7 11.1 08/21/2006 01:00:00 8 0.6 9.5 6.5 7.8 0.6 9.1 6.5 6.1 0.7 8.4 4.6 304 3 305 165 11.5 0 11.7 11.4 08/21/2006 01:10:00 8.1 0.6 9.9 6.8 8 0.6 10.3 6.8 6.2 0.7 9.1 4.6 304 4 303 165 11.5 0 11.7 11.4 08/21/2006 01:20:00 7.6 0.7 10.7 5.7 7.5 0.7 11.5 5.7 5.9 0.8 9.9 4.6 304 3 307 165 11.4 0 11.7 11.4 08/21/2006 01:30:00 7.8 0.8 9.5 5.7 7.7 0.7 9.5 4.9 6 0.8 8 4.2 303 5 320 165 11.4 0 11.7 11.1 08/21/2006 01:40:00 7.8 0.4 9.1 6.5 7.7 0.4 8.8 6.5 6.3 0.6 8 4.6 305 3 300 165 11.5 0 11.9 11.1 08/21/2006 01:50:00 8.2 0.8 10.7 6.1 8.1 0.8 10.3 5.7 7.1 1 10.3 4.2 310 5 313 165 11.3 0 11.7 11.1 08/21/2006 02:00:00 8.7 0.8 10.3 6.1 8.4 0.8 10.3 6.5 7.4 0.9 10.3 4.2 310 4 312 165 11.5 0 11.7 11.4 08/21/2006 02:10:00 9 0.7 10.7 7.6 8.8 0.7 10.7 7.2 7.7 0.8 9.9 5.7 310 3 307 165 11.6 0 11.9 11.4 08/21/2006 02:20:00 8.8 0.8 10.7 6.5 8.6 0.7 10.7 6.5 7.7 0.8 9.9 4.9 310 5 310 165 11.6 0 11.9 11.4 08/21/2006 02:30:00 9 0.8 11.1 7.2 8.8 0.8 11.1 6.8 7.5 1 10.3 4.9 308 5 312 165 11.6 0 11.7 11.4 08/21/2006 02:40:00 9.4 0.8 11.5 7.2 9.3 0.8 11.1 7.2 7.8 1 9.9 4.6 307 5 301 165 11.7 0.2 11.9 11.4 08/21/2006 02:50:00 8 0.8 9.9 5.7 7.9 0.8 9.5 5.3 6.7 0.9 8.8 3.8 305 4 308 165 11.5 0 11.9 11.4 08/21/2006 03:00:00 7.5 0.4 8.4 6.1 7.4 0.4 8.8 5.7 5.8 0.6 7.6 4.2 301 5 308 165 11.2 0 11.7 11.1 08/21/2006 03:10:00 6.5 0.6 8 4.9 6.5 0.5 7.6 4.9 5 0.7 7.2 3.4 299 5 296 165 11.1 0 11.7 10.6 08/21/2006 03:20:00 6.5 0.8 8.8 4.6 6.4 0.7 8.4 4.9 4.8 0.7 6.8 3.4 298 4 303 165 10.9 0.2 11.1 10.3 08/21/2006 03:30:00 7.9 1.1 12.2 5.7 7.7 1.1 11.8 5.7 6 1.2 9.5 3.8 301 7 301 165 10.7 0.1 11.1 10.3 08/21/2006 03:40:00 7.8 1.2 11.1 4.6 7.7 1.2 10.7 4.2 6.2 1.3 11.1 3.4 304 11 291 165 11.3 0.1 11.7 10.9 08/21/2006 03:50:00 5.4 1 8.4 2.6 5.3 1 8.4 3 5.2 0.8 7.6 2.6 327 14 309 165 11.1 0.2 11.7 10.6 08/21/2006 04:00:00 8.5 1.4 13 5.3 8.4 1.4 12.6 5.3 7.1 1.3 11.1 3.4 304 10 308 165 11.7 0.4 12.2 10.9 08/21/2006 04:10:00 8.1 1.5 12.2 4.2 8.1 1.4 11.8 4.2 6.4 1.3 9.9 2.6 304 9 294 165 11.3 0.2 11.9 10.6 08/21/2006 04:20:00 8.8 1 11.5 5.7 8.7 1 11.1 5.7 7 1.1 11.1 4.2 303 6 302 165 11.2 0.1 11.7 10.6 08/21/2006 04:30:00 9.5 1 13.3 7.6 9.4 0.9 13.3 7.6 7.5 1 10.7 4.9 304 6 297 165 11.5 0 11.9 10.9 08/21/2006 04:40:00 8.9 0.9 11.1 6.5 8.8 0.8 10.7 6.8 7.2 0.8 9.1 5.3 306 6 298 165 11.3 0.1 11.9 10.9 08/21/2006 04:50:00 8 0.8 9.9 5.7 8 0.8 9.5 5.7 6.9 0.9 9.5 4.2 310 7 309 165 11.1 0.1 11.7 10.9 08/21/2006 05:00:00 6.9 1 9.9 3.4 6.8 0.9 9.9 3.4 6.5 1 9.9 3.8 317 9 313 165 10.7 0.1 11.1 10.1 08/21/2006 05:10:00 7 1 9.9 4.6 7 1 9.9 4.9 5.9 1.1 8.8 3 310 7 303 165 10.8 0 11.1 10.6 08/21/2006 05:20:00 5.5 0.8 8.4 2.6 5.5 0.8 8 3 4 1 6.5 1.9 305 8 317 165 10.6 0 10.9 10.3 08/21/2006 05:30:00 4.9 0.9 6.5 1.9 5 0.9 6.8 1.9 3.6 0.9 6.1 1.5 294 9 296 165 10.7 0.1 11.1 10.3 08/21/2006 05:40:00 5.2 0.6 6.8 3 5.2 0.6 6.8 2.6 4 0.8 6.1 1.1 298 6 305 165 10.7 0.1 11.1 10.3 08/21/2006 05:50:00 5 0.5 6.1 3.8 5 0.5 6.1 3.4 3.9 0.5 5.3 1.9 299 4 299 165 10.6 0.1 10.9 10.3 08/21/2006 06:00:00 4.7 0.5 5.7 3.4 4.8 0.5 5.7 3.4 3.8 0.5 6.1 2.6 295 4 300 165 10.9 0.2 11.4 10.3 08/21/2006 06:10:00 3.9 0.5 5.3 2.6 4 0.5 4.9 2.6 3.1 0.5 4.9 1.9 299 5 300 165 11.5 0.2 12.2 11.1 08/21/2006 06:20:00 4.1 0.4 4.9 3.4 4.2 0.3 5.3 3.4 3.2 0.4 4.6 2.3 302 3 304 165 11.9 0 12.2 11.9 08/21/2006 06:30:00 3.4 0.6 4.9 2.3 3.5 0.6 4.9 2.3 2.9 0.6 4.9 1.9 301 6 305 165 12 0 12.5 11.9 08/21/2006 06:40:00 3.4 0.5 4.2 2.3 3.5 0.4 4.2 2.3 3.1 0.5 4.2 1.9 305 3 308 165 12.5 0.1 12.7 11.9 08/21/2006 06:50:00 3 0.5 4.2 1.9 3 0.5 4.2 1.9 2.6 0.5 3.8 1.5 304 3 306 165 12.9 0.1 13.3 12.5 08/21/2006 07:00:00 3 0.4 3.8 2.3 3.1 0.4 3.8 2.3 2.3 0.3 3 1.5 296 4 294 165 13.3 0 13.3 12.7 08/21/2006 07:10:00 2.7 0.4 3.8 1.9 2.7 0.4 3.8 1.9 2.2 0.3 3 1.5 299 5 291 165 13.3 0.2 13.8 12.7 08/21/2006 07:20:00 2.6 0.5 3.8 1.1 2.5 0.5 3.4 1.1 2.1 0.5 3.8 0.7 296 7 295 165 13.8 0 14.1 13.5 08/21/2006 07:30:00 2.2 0.3 3 1.5 2.1 0.4 3 1.1 2.1 0.4 3 1.1 288 6 281 165 14.1 0 14.4 13.5 08/21/2006 07:40:00 1.6 0.4 2.6 0.7 1.5 0.4 2.6 0.7 1.4 0.3 2.3 0.7 294 5 301 165 14.4 0.1 14.6 14.4 08/21/2006 07:50:00 1.7 0.4 2.6 0.7 1.5 0.5 2.6 0.4 1.6 0.3 2.3 0.7 291 8 301 165 14.6 0 14.9 14.4 08/21/2006 08:00:00 0.6 0.3 1.5 0.4 0.4 0.2 1.5 0.4 0.7 0.4 1.9 0.4 286 3 291 165 15.7 0.4 16.3 14.9 08/21/2006 08:10:00 0.7 0.4 1.9 0.4 0.7 0.4 1.9 0.4 1 0.5 1.9 0.4 214 39 172 165 15.7 0.3 16.3 15.5 08/21/2006 08:20:00 1.2 0.5 2.3 0.4 1.8 0.8 3.4 0.4 1.6 0.8 3 0.4 252 21 259 165 15.5 0 16 15.2 08/21/2006 08:30:00 1.7 0.5 3 0.7 2.1 0.4 3.4 1.1 2.1 0.5 3 0.7 240 17 244 165 15.4 0 15.7 15.2 08/21/2006 08:40:00 1.2 0.6 2.6 0.4 1.6 0.6 3 0.4 1.3 0.6 2.6 0.4 238 13 206 165 15.7 0.2 16.6 15.5 08/21/2006 08:50:00 2.1 0.7 4.2 0.4 2.3 0.6 4.2 0.7 2.3 0.6 3.8 1.1 176 24 148 165 16 0 16.8 15.7 08/21/2006 09:00:00 2.7 0.5 4.6 1.1 2.8 0.5 4.6 1.5 2.8 0.5 4.6 1.5 175 12 165 165 15.9 0 16.3 15.7 08/21/2006 09:10:00 2.3 0.5 3.8 1.1 2.5 0.5 4.2 1.1 2.6 0.5 3.8 1.5 179 13 165 165 15.7 0 16 15.5 08/21/2006 09:20:00 2.5 0.5 4.2 1.5 2.7 0.5 4.2 1.5 2.6 0.4 3.8 1.5 166 13 171 165 15.8 0 16 15.7 08/21/2006 09:30:00 1.8 0.8 4.2 0.4 2 0.7 3.8 0.7 2.1 0.7 3.8 0.4 152 11 162 165 16 0 16.3 15.7 08/21/2006 09:40:00 1.1 0.8 3 0.4 1.4 0.7 3.4 0.4 1.4 0.9 3.8 0.4 166 17 145 165 16.3 0.1 16.6 15.5 08/21/2006 09:50:00 2 0.7 4.2 0.4 2.3 0.6 4.2 1.1 2.4 0.7 4.2 0.4 162 11 162 165 16.6 0 16.8 16.3 08/21/2006 10:00:00 2.3 0.6 3.8 0.7 2.5 0.6 3.8 1.1 2.6 0.5 4.2 0.7 159 11 152 165 16.2 0.1 16.6 16 08/21/2006 10:10:00 3.4 0.6 4.9 2.3 3.5 0.6 4.9 2.3 3.6 0.6 5.3 2.3 156 11 152 165 16.1 0.1 16.6 16 08/21/2006 10:20:00 3.6 0.6 5.7 1.9 3.8 0.6 5.7 2.3 3.8 0.5 5.3 2.3 147 11 158 165 16.2 0 16.6 16.3 08/21/2006 10:30:00 3.9 0.6 6.1 2.3 3.9 0.6 6.1 2.6 4 0.6 6.1 2.6 145 10 124 165 16.1 0 16.6 16 08/21/2006 10:40:00 3.9 0.5 5.3 2.6 4 0.5 5.3 2.6 4 0.6 6.1 2.6 146 9 135 165 15.9 0 16.3 15.7 08/21/2006 10:50:00 4.7 0.5 6.1 3.8 4.7 0.5 6.1 3.4 4.8 0.5 6.1 3.8 150 9 162 165 15.7 0 16.3 15.5 08/21/2006 11:00:00 4.4 0.6 5.7 2.3 4.5 0.5 6.5 2.6 4.5 0.6 6.5 2.6 151 10 144 165 16 0.1 16.3 15.7 08/21/2006 11:10:00 4.1 0.8 5.7 1.9 4.2 0.7 5.7 2.3 4.4 0.8 6.5 2.3 151 10 164 165 15.2 0.1 15.7 14.9 08/21/2006 11:20:00 4.8 0.8 6.5 2.6 4.8 0.7 6.8 3 5 0.8 7.2 2.3 164 8 160 165 16.1 0.4 16.8 15.2 08/21/2006 11:30:00 6 0.7 8.4 4.2 5.9 0.6 7.6 3.8 6.1 0.7 8 3.8 169 8 166 165 15.3 0.2 16.3 15.2 08/21/2006 11:40:00 6.6 1 9.1 4.6 6.5 0.9 8.8 4.6 6.8 1 9.1 4.9 163 7 165 165 16.4 0.2 16.8 15.7 08/21/2006 11:50:00 7.5 0.7 9.5 5.7 7.3 0.7 9.1 5.7 7.7 0.7 9.1 5.7 163 12 164 165 16.5 0 16.8 16.3 08/21/2006 12:00:00 6.9 1 9.1 4.2 6.8 0.9 8.8 4.2 7.1 1 9.1 4.9 168 6 165 165 16.4 0 16.8 16 08/21/2006 12:10:00 8.1 0.9 10.3 6.5 7.9 0.8 9.9 6.1 8.2 0.9 10.3 6.1 165 7 165 165 16.3 0.4 16.8 15.5 08/21/2006 12:20:00 9.3 0.8 11.5 7.2 9 0.8 11.1 7.2 9.2 0.8 11.5 7.2 166 5 162 165 15.3 0 15.7 15.2 08/21/2006 12:30:00 10.2 0.6 11.8 8.4 9.9 0.6 11.5 8.4 10.1 0.8 11.8 7.6 167 16 161 165 16.1 0.4 16.8 15.5 08/21/2006 12:40:00 9.6 0.8 11.5 7.6 9.4 0.8 11.5 7.2 9.7 0.8 11.5 7.6 167 12 164 165 16.1 0.2 16.6 15.7 08/21/2006 12:50:00 9.1 0.8 11.5 7.2 8.9 0.7 11.1 7.2 9.1 0.8 11.5 6.8 167 5 164 165 15.8 0.1 16.3 15.7 08/21/2006 13:00:00 10.2 0.9 12.2 7.6 9.9 0.8 12.2 7.2 10.4 0.9 12.2 8 164 6 165 165 15.5 0.2 16 15.2 08/21/2006 13:10:00 10.3 1 12.6 8 10 0.9 12.2 7.6 10.4 1 13 8 168 9 165 165 15.3 0.3 16.3 14.6 08/21/2006 13:20:00 11 0.8 12.6 8.4 10.6 0.7 12.2 8 11.3 0.8 12.6 8 168 9 172 165 16.3 0.1 16.8 15.7 08/21/2006 13:30:00 9.9 0.8 11.8 7.6 9.6 0.7 11.1 7.6 10 0.9 12.2 8 168 12 169 165 15.9 0 16.3 15.5 08/21/2006 13:40:00 9.5 1 11.5 6.8 9.3 0.8 11.1 7.2 9.5 0.9 11.5 7.2 167 11 166 165 14.9 0.2 15.7 14.4 08/21/2006 13:50:00 10.3 1 11.8 6.5 10 0.9 11.5 6.1 10.3 0.9 12.6 8 167 11 169 165 14.6 0 14.9 14.4 08/21/2006 14:00:00 9.5 0.9 11.1 6.5 9.2 0.8 10.7 6.5 9.4 1 11.5 6.1 169 11 165 165 14.3 0 14.6 14.1 08/21/2006 14:10:00 8.6 1.2 11.1 5.7 8.4 1.1 10.7 5.7 8.6 1.2 11.1 5.7 171 6 170 165 14.4 0 14.6 14.4 08/21/2006 14:20:00 7.4 0.8 9.1 4.9 7.3 0.7 8.8 4.9 7.2 0.7 8.8 4.9 168 6 174 165 14.5 0 14.9 14.4 08/21/2006 14:30:00 6.4 1.1 9.1 3.4 6.4 1 8.8 3.8 6.4 1 8.8 4.2 164 11 160 165 14.4 0 14.6 14.4 08/21/2006 14:40:00 5.1 0.8 6.8 2.6 5.1 0.8 6.8 2.6 5.3 0.8 7.6 3 152 11 145 165 13.9 0.1 14.4 13.5 08/21/2006 14:50:00 3.8 0.8 6.5 1.9 4 0.8 6.5 2.3 4 0.8 6.5 2.3 159 14 171 165 14.3 0.2 14.9 13.5 08/21/2006 15:00:00 5 0.8 6.8 2.6 5 0.8 6.5 2.6 5.1 0.9 8 2.3 160 11 158 165 14.7 0 14.9 14.6 08/21/2006 15:10:00 4.9 1.1 7.6 2.3 5 1 7.6 2.6 5.1 1 8 3 161 12 172 165 14.6 0 14.9 14.4 08/21/2006 15:20:00 5.2 1.1 7.6 2.3 5.2 1 7.2 2.3 5.4 0.9 7.6 3.4 160 10 172 165 14.6 0 14.9 14.4 08/21/2006 15:30:00 3.9 1 6.1 0.7 3.9 0.9 6.1 1.1 4.2 0.9 6.5 1.9 159 9 162 165 14.4 0.1 14.9 14.1 08/21/2006 15:40:00 2.4 0.6 4.2 1.1 2.6 0.6 4.2 1.5 2.8 0.5 4.2 1.5 162 18 160 165 14.6 0 14.9 14.1 08/21/2006 15:50:00 2 0.4 3 0.7 2.2 0.4 3.4 0.7 2.6 0.4 3.8 1.9 125 13 102 165 14.2 0.2 14.9 13.5 08/21/2006 16:00:00 2.5 0.5 4.2 1.5 2.6 0.5 4.2 1.5 3 0.5 4.9 1.9 151 15 118 165 14.2 0 14.6 14.1 08/21/2006 16:10:00 2.8 0.5 3.8 1.5 2.9 0.5 4.2 1.9 3.2 0.4 4.2 1.9 123 10 119 165 13.9 0.1 14.4 13.5 08/21/2006 16:20:00 1.4 0.9 3.4 0.4 1.6 1 3.4 0.4 2.1 0.7 3.4 0.7 127 15 129 165 14 0.1 14.4 13.5 08/21/2006 16:30:00 0.6 0.4 1.5 0.4 0.7 0.5 1.9 0.4 1 0.5 2.3 0.4 155 112 324 165 14.6 0.2 15.2 13.8 08/21/2006 16:40:00 0.8 0.5 1.9 0.4 0.8 0.4 1.9 0.4 1.4 0.6 2.6 0.4 345 7 358 165 15.2 0 15.5 14.9 08/21/2006 16:50:00 1.7 0.5 3 0.7 1.5 0.7 3 0.4 2.3 0.3 3 1.5 352 5 348 165 15.2 0 15.5 15.2 08/21/2006 17:00:00 2.1 0.4 3 1.1 1.5 0.6 3 0.4 2.6 0.3 3.4 1.9 3 8 351 165 15.2 0 15.5 15.2 08/21/2006 17:10:00 1.7 0.4 2.6 1.1 1.5 0.6 3 0.4 2.4 0.3 3 1.9 17 6 15 165 15.1 0 15.5 14.6 08/21/2006 17:20:00 1.6 0.3 2.6 1.1 0.8 0.5 2.3 0.4 2.2 0.2 3 1.9 358 5 351 165 15 0 15.2 14.6 08/21/2006 17:30:00 1.6 0.3 2.3 0.7 1.4 0.5 2.6 0.4 2.3 0.3 3 1.5 14 7 21 165 15 0.1 15.2 14.6 08/21/2006 17:40:00 2.2 0.5 3.4 1.1 2.3 0.6 3.4 1.1 2.9 0.4 3.8 2.3 24 3 25 165 14.7 0.2 15.2 14.1 08/21/2006 17:50:00 2.3 0.4 3 1.5 2 0.7 3.4 0.7 2.7 0.4 3.8 1.9 16 6 28 165 14.6 0.1 14.9 14.1 08/21/2006 18:00:00 0.9 0.5 2.3 0.4 0.8 0.5 2.3 0.4 1.6 0.6 2.6 0.4 356 27 26 165 15 0.2 15.2 14.1 08/21/2006 18:10:00 0.4 0.2 1.1 0.4 0.4 0.1 1.1 0.4 0.6 0.4 1.9 0.4 350 2 354 165 14.7 0.3 15.5 14.4 08/21/2006 18:20:00 0.7 0.4 1.5 0.4 0.7 0.4 1.9 0.4 1 0.4 1.5 0.4 178 76 194 165 14.6 0.1 14.9 14.1 08/21/2006 18:30:00 1.8 0.6 2.6 0.4 1.8 0.7 3 0.4 1.8 0.6 3 0.4 213 6 208 165 14.3 0 14.6 14.1 08/21/2006 18:40:00 2 0.6 3.8 1.1 2.1 0.6 3.8 1.1 2.2 0.5 3.8 0.4 227 9 236 165 14.6 0.1 14.6 14.1 08/21/2006 18:50:00 2.2 0.5 3.4 1.1 2.3 0.5 3.4 1.1 2.5 0.5 3.4 1.1 221 10 227 165 14.6 0 14.6 14.1 08/21/2006 19:00:00 2.9 0.7 4.2 0.7 3 0.7 4.6 1.1 3.1 0.7 4.6 1.5 224 9 215 165 14.5 0 14.6 13.8 08/21/2006 19:10:00 2.5 0.5 3.8 1.1 2.6 0.5 3.8 1.5 2.7 0.5 4.2 1.5 222 10 205 165 14.4 0 14.6 14.4 08/21/2006 19:20:00 2.9 0.5 4.2 1.5 2.9 0.5 3.8 1.5 3.3 0.5 4.6 1.9 193 12 194 165 14.2 0.1 14.6 14.1 08/21/2006 19:30:00 3.8 0.4 4.9 2.6 3.7 0.5 4.6 2.6 4 0.4 4.9 3 185 6 207 165 13.9 0 14.1 13.5 08/21/2006 19:40:00 4.4 0.6 5.7 3 4.4 0.6 6.1 3 4.5 0.6 6.1 3 197 6 204 165 13.7 0 13.8 13.3 08/21/2006 19:50:00 3.5 0.6 4.9 1.9 3.5 0.6 4.9 2.3 3.6 0.7 5.3 2.3 195 9 203 165 13.6 0 13.8 13.3 08/21/2006 20:00:00 3.4 0.5 4.6 2.3 3.4 0.4 4.2 2.3 3.5 0.5 4.6 2.3 179 8 183 165 13.4 0 13.5 13 08/21/2006 20:10:00 4.1 0.6 5.7 3 4 0.6 5.7 3 4.2 0.6 5.7 2.6 172 12 183 165 13.3 0 13.5 12.7 08/21/2006 20:20:00 4.1 0.5 5.3 3.4 4 0.5 5.3 3 4.3 0.5 5.3 3.4 164 8 165 165 13.3 0 13.5 13 08/21/2006 20:30:00 3.5 0.5 4.9 2.3 3.5 0.5 4.9 2.3 3.6 0.5 4.9 2.3 152 9 165 165 13 0.1 13.3 12.7 08/21/2006 20:40:00 3.2 0.4 3.8 2.3 3.1 0.4 3.8 2.3 3.3 0.4 4.2 1.9 160 11 146 165 12.8 0 13 12.5 08/21/2006 20:50:00 2.4 0.6 3.8 1.1 2.5 0.5 3.8 1.1 2.7 0.4 4.2 1.5 171 9 191 165 12.8 0 13 12.5 08/21/2006 21:00:00 2.6 0.6 4.2 1.1 2.7 0.5 4.2 1.5 2.6 0.5 4.2 1.5 190 9 181 165 12.9 0 13.3 12.7 08/21/2006 21:10:00 2.4 0.4 3.4 0.7 2.5 0.4 3.4 1.1 2.6 0.4 3.4 1.5 183 13 196 165 13 0 13.3 12.7 08/21/2006 21:20:00 2.4 0.5 3.8 1.1 2.4 0.5 3.8 1.1 2.5 0.5 3.8 1.1 176 9 176 165 13.1 0 13.3 12.7 08/21/2006 21:30:00 1.8 0.4 2.6 1.1 1.8 0.4 2.6 0.7 2.1 0.3 2.6 1.5 175 14 199 165 13.1 0 13.3 13 08/21/2006 21:40:00 2.1 0.4 2.6 0.7 2.1 0.4 3 0.4 2.5 0.3 3 1.5 136 13 133 165 12.9 0 13 12.5 08/21/2006 21:50:00 1.4 0.4 2.3 0.4 1.4 0.4 2.3 0.4 1.9 0.4 2.6 0.7 147 16 116 165 12.5 0 12.7 12.2 08/21/2006 22:00:00 1.7 0.5 3 0.7 1.7 0.5 2.6 0.4 2 0.4 3 1.1 167 8 173 165 12.8 0.1 13 12.5 08/21/2006 22:10:00 2.1 0.4 3 1.1 2.1 0.3 3.4 1.1 2.4 0.3 3 1.5 167 6 164 165 12.9 0.1 13 12.5 08/21/2006 22:20:00 1.8 0.4 2.6 0.7 1.9 0.4 2.6 0.7 2.1 0.4 2.6 0.7 170 11 170 165 12.8 0.1 13 12.5 08/21/2006 22:30:00 2.6 0.4 4.2 1.5 2.6 0.4 3.8 1.5 2.9 0.3 3.8 2.3 164 8 174 165 12.7 0 13 12.2 08/21/2006 22:40:00 2.5 0.5 3.8 1.1 2.5 0.5 3.8 0.7 2.6 0.6 3.8 1.5 176 18 164 165 12.2 0.2 12.7 11.9 08/21/2006 22:50:00 2 0.5 3 0.7 2 0.5 3 0.7 2.1 0.4 3 1.1 181 14 198 165 12.5 0 12.7 11.9 08/21/2006 23:00:00 1.1 0.5 2.3 0.4 1 0.5 2.3 0.4 1.3 0.4 2.3 0.4 171 14 165 165 12.6 0.1 12.7 12.2 08/21/2006 23:10:00 1.2 0.8 3 0.4 1.2 0.9 3.4 0.4 1.6 0.9 3.4 0.4 170 18 150 165 12.5 0.1 13 12.2 08/21/2006 23:20:00 2 0.5 3.4 0.4 2 0.6 3.4 0.4 2.5 0.4 3.4 1.5 152 8 164 165 12.5 0.2 12.7 12.2 08/21/2006 23:30:00 2.9 0.3 3.8 1.9 2.8 0.3 3.4 1.9 3.1 0.3 3.8 2.6 161 9 176 165 12.3 0.2 12.7 11.9 08/21/2006 23:40:00 4 0.5 4.9 2.6 3.9 0.5 4.9 2.6 4.1 0.6 5.3 3 158 11 165 165 12.3 0.2 12.7 11.9 08/21/2006 23:50:00 3.5 0.4 4.6 2.6 3.3 0.4 4.2 2.6 3.6 0.4 4.6 2.6 152 6 153 165 11.9 0.3 12.5 11.4 08/22/2006 00:00:00 2.7 0.4 3.4 1.9 2.6 0.4 3.4 1.9 2.7 0.4 3.8 1.9 154 4 151 165 11.6 0.2 11.9 11.1 08/22/2006 00:10:00 3.5 0.4 4.6 2.3 3.3 0.4 4.2 1.9 3.3 0.3 4.2 2.6 168 7 179 165 11.7 0.1 11.9 11.1 08/22/2006 00:20:00 2.8 0.5 3.8 1.9 2.7 0.5 3.4 1.9 2.9 0.4 3.8 2.3 160 5 174 165 11.9 0 11.9 11.7 08/22/2006 00:30:00 3.7 0.5 4.6 2.3 3.6 0.4 4.2 2.3 3.7 0.5 4.6 2.3 150 4 156 165 11.9 0 12.2 11.4 08/22/2006 00:40:00 3.6 0.3 4.6 3 3.5 0.3 4.2 2.6 3.8 0.3 4.6 2.6 153 8 150 165 11.9 0.1 12.2 11.4 08/22/2006 00:50:00 3.3 0.5 4.6 2.3 3.2 0.5 4.2 2.3 3.4 0.5 4.6 2.3 158 10 170 165 11.8 0 12.5 11.4 08/22/2006 01:00:00 3.2 0.2 3.8 2.6 3.1 0.2 3.8 2.6 3.2 0.2 3.8 2.6 157 8 163 165 11.9 0.1 12.2 11.4 08/22/2006 01:10:00 3.1 0.5 3.8 1.5 2.9 0.6 3.8 1.5 3.2 0.6 4.2 1.5 156 6 161 165 11.9 0 12.2 11.4 08/22/2006 01:20:00 1.7 0.5 3 0.4 1.6 0.5 2.6 0.4 1.8 0.4 2.6 0.7 167 22 206 165 12 0 12.2 11.4 08/22/2006 01:30:00 1.8 0.5 2.6 0.7 1.7 0.5 3 0.7 2 0.4 3 1.1 176 13 208 165 12.5 0 12.7 11.9 08/22/2006 01:40:00 1.5 0.5 2.6 0.4 1.4 0.5 2.6 0.4 1.7 0.5 2.6 0.4 178 14 193 165 12.7 0.1 13.3 12.2 08/22/2006 01:50:00 2.5 0.6 3.8 1.1 2.4 0.5 3.8 1.1 2.6 0.5 4.2 1.5 166 8 161 165 12.7 0 13.3 11.9 08/22/2006 02:00:00 3.8 0.6 4.9 2.3 3.6 0.6 4.6 2.3 3.8 0.6 4.9 2.3 162 5 161 165 12.7 0 13 12.2 08/22/2006 02:10:00 3.9 0.4 4.9 3 3.7 0.4 4.6 2.6 3.8 0.4 4.9 2.6 169 10 164 165 12.5 0.2 12.7 11.9 08/22/2006 02:20:00 4.2 0.7 5.7 2.6 4 0.6 5.3 2.6 4 0.7 5.3 2.6 188 10 182 165 12.5 0.2 13 11.9 08/22/2006 02:30:00 3.2 0.4 4.2 2.3 3.1 0.4 4.2 2.3 3 0.4 4.2 1.5 201 8 185 165 12.8 0.3 13.3 12.2 08/22/2006 02:40:00 3.6 0.4 4.6 2.6 3.4 0.4 4.2 2.6 3.5 0.5 4.6 2.6 187 4 183 165 13 0.1 13.3 12.5 08/22/2006 02:50:00 3.1 0.4 4.2 2.3 3 0.4 3.8 2.3 3 0.5 4.2 2.3 186 8 184 165 12.9 0.1 13.3 12.5 08/22/2006 03:00:00 3.6 0.5 4.6 2.6 3.4 0.5 4.6 2.6 3.6 0.5 4.9 2.6 159 5 154 165 12.8 0.2 13 12.2 08/22/2006 03:10:00 4 0.4 4.9 3.4 3.8 0.4 4.6 3 4.1 0.4 4.9 3 143 6 148 165 12.1 0.2 12.7 11.7 08/22/2006 03:20:00 4.5 0.5 5.7 3.4 4.3 0.5 5.3 3 4.5 0.5 6.1 3 155 5 151 165 11.7 0.3 12.2 11.1 08/22/2006 03:30:00 3.3 0.4 4.2 2.3 3.2 0.4 4.2 2.3 3.3 0.4 4.2 2.3 142 5 152 165 11.9 0 12.5 11.4 08/22/2006 03:40:00 2.7 0.5 3.8 1.5 2.6 0.6 3.4 1.1 2.8 0.6 3.8 1.1 151 16 145 165 12 0 12.5 11.4 08/22/2006 03:50:00 3.3 0.8 5.7 1.9 3.3 0.8 5.7 1.9 3.2 0.8 5.7 1.5 198 13 213 165 13 0.4 14.1 12.2 08/22/2006 04:00:00 4.3 0.5 5.7 2.6 4.3 0.5 5.3 2.6 4.4 0.5 5.3 3 205 6 204 165 13.9 0.2 14.4 13.5 08/22/2006 04:10:00 4.2 0.5 5.3 3 4.1 0.5 5.3 2.6 4.1 0.5 5.3 2.6 205 6 207 165 13.6 0.1 14.1 13.3 08/22/2006 04:20:00 2.5 1.2 4.9 0.4 2.4 1.3 4.9 0.4 2.4 1.2 4.9 0.4 184 18 204 165 13.4 0.2 13.8 13 08/22/2006 04:30:00 2.6 1 4.6 0.7 2.6 1 4.6 0.4 2.6 1 4.9 0.4 235 39 203 165 13.7 0.6 14.9 13 08/22/2006 04:40:00 1.7 1 3.4 0.4 1.6 1 3.4 0.4 2 1 3.8 0.4 177 10 200 165 14.1 0.4 14.9 13.3 08/22/2006 04:50:00 1.2 1 3.4 0.4 1.1 0.9 3 0.4 1.4 0.7 2.6 0.4 201 82 198 165 13 0.2 13.5 12.5 08/22/2006 05:00:00 0.6 0.4 1.9 0.4 0.5 0.4 1.9 0.4 1 0.5 2.3 0.4 307 86 167 165 12.3 0.2 12.7 11.7 08/22/2006 05:10:00 1 0.6 2.3 0.4 1 0.6 2.6 0.4 1.3 0.6 2.3 0.4 289 49 244 165 12.3 0.2 12.7 11.9 08/22/2006 05:20:00 2.1 0.8 4.2 0.4 2.2 0.9 4.2 0.4 1.7 0.8 3.8 0.4 271 14 256 165 12.7 0.3 13.3 12.2 08/22/2006 05:30:00 2.2 0.5 3.8 0.7 2.5 0.7 4.2 0.7 2.2 0.5 3.4 0.4 243 13 275 165 13.5 0.4 14.4 12.7 08/22/2006 05:40:00 1.9 0.5 3 0.7 1.9 0.5 3.4 0.7 1.9 0.5 3 0.7 211 15 223 165 13.9 0.2 14.6 13.3 08/22/2006 05:50:00 3.2 0.6 4.6 1.9 3 0.6 4.2 1.5 2.9 0.6 3.8 1.5 177 7 165 165 13.4 0.3 13.8 12.5 08/22/2006 06:00:00 2.6 0.6 3.8 1.1 2.4 0.6 3.4 0.4 2.5 0.6 3.8 0.7 198 10 199 165 13.1 0.3 13.5 12.5 08/22/2006 06:10:00 3.6 0.7 4.9 1.9 3.6 0.8 4.9 1.5 3.6 0.5 4.6 2.3 208 6 216 165 13.8 0.2 14.1 13 08/22/2006 06:20:00 3.2 0.4 4.2 2.3 3.1 0.5 4.2 1.9 3 0.5 4.2 1.9 203 8 210 165 13.7 0.2 14.1 13.3 08/22/2006 06:30:00 3 0.7 4.2 1.1 3 0.7 4.2 0.7 2.9 0.7 4.2 1.1 208 7 211 165 13.7 0.1 14.1 13.3 08/22/2006 06:40:00 3.2 0.6 4.6 2.3 3.2 0.7 4.6 2.3 3.2 0.6 4.6 1.5 208 7 210 165 13.9 0.2 14.1 13.3 08/22/2006 06:50:00 1.1 0.9 2.6 0.4 1.1 0.9 2.6 0.4 1.3 1 3 0.4 228 15 205 165 13.8 0 14.4 13.5 08/22/2006 07:00:00 1.1 0.6 3 0.4 1.1 0.6 3 0.4 1.3 0.6 2.3 0.4 233 43 271 165 13.5 0.1 13.8 13 08/22/2006 07:10:00 0.9 0.4 2.3 0.4 0.9 0.5 2.3 0.4 1.1 0.4 2.3 0.4 253 13 237 165 13.8 0.1 14.4 13.3 08/22/2006 07:20:00 1.9 0.8 3.4 0.4 1.8 0.8 3.4 0.4 2.2 0.4 3 0.7 281 7 290 165 13.3 0 13.5 13 08/22/2006 07:30:00 1.2 0.8 3 0.4 1.3 0.8 3.4 0.4 1.4 0.7 3 0.4 258 17 278 165 13.7 0.2 14.1 13 08/22/2006 07:40:00 1.9 0.8 3.4 0.4 1.7 1 3.4 0.4 2.1 0.8 3.4 0.4 313 10 304 165 13.1 0.2 13.5 12.7 08/22/2006 07:50:00 0.9 0.6 2.6 0.4 0.7 0.6 2.3 0.4 1 0.7 2.6 0.4 340 66 122 165 13.2 0.3 13.8 12.7 08/22/2006 08:00:00 0.8 0.5 2.3 0.4 0.6 0.4 2.3 0.4 1 0.6 2.6 0.4 76 16 103 165 13.6 0.2 14.1 13.3 08/22/2006 08:10:00 1 0.6 2.6 0.4 0.7 0.5 2.3 0.4 1.2 0.7 2.3 0.4 79 45 15 165 13.7 0 14.1 13.5 08/22/2006 08:20:00 0.4 0.1 0.7 0.4 0.4 0 0.4 0.4 0.4 0.1 1.1 0.4 11 82 305 165 13.7 0 13.8 13.3 08/22/2006 08:30:00 0.4 0.1 0.7 0.4 0.4 0 0.4 0.4 0.4 0.1 0.7 0.4 258 53 211 165 13.7 0 13.8 13.5 08/22/2006 08:40:00 1.1 0.4 1.9 0.4 0.7 0.4 1.5 0.4 1.2 0.4 1.9 0.4 156 17 145 165 13.4 0 13.8 13 08/22/2006 08:50:00 0.7 0.3 1.5 0.4 0.4 0.1 1.1 0.4 0.8 0.3 1.5 0.4 122 66 140 165 12.9 0.1 13.3 12.5 08/22/2006 09:00:00 0.4 0.2 1.1 0.4 0.4 0 0.4 0.4 0.5 0.3 1.5 0.4 347 2 336 165 13.3 0.2 13.5 12.7 08/22/2006 09:10:00 0.5 0.3 1.5 0.4 0.4 0.2 1.1 0.4 0.6 0.4 1.9 0.4 175 58 207 165 13.6 0 13.8 13 08/22/2006 09:20:00 2 0.5 3 1.1 1.9 0.6 3 0.4 1.6 0.7 3 0.4 256 32 276 165 13.5 0.1 13.8 13 08/22/2006 09:30:00 2.6 0.3 3.4 1.9 2.5 0.3 3.4 1.5 2.2 0.4 3 1.1 298 5 301 165 13.9 0.2 14.1 13.3 08/22/2006 09:40:00 2.5 0.2 3 1.9 2.4 0.2 3 1.9 2.7 0.2 3 2.3 318 4 314 165 14.1 0.1 14.4 13.5 08/22/2006 09:50:00 2.1 0.7 3 0.4 2.1 0.8 3 0.4 1.9 0.6 3 0.7 297 8 311 165 14.3 0 14.6 13.8 08/22/2006 10:00:00 0.4 0 0.7 0.4 0.4 0 0.4 0.4 0.4 0.1 0.7 0.4 288 2 287 165 14.6 0 14.9 14.4 08/22/2006 10:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 31 112 165 165 15 0.1 15.2 14.9 08/22/2006 10:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 155 0 165 165 14.8 0 15.2 14.9 08/22/2006 10:30:00 1.2 0.5 1.9 0.4 1 0.5 1.9 0.4 1.4 0.6 2.3 0.4 135 13 141 165 14.8 0 15.2 14.6 08/22/2006 10:40:00 0.8 0.4 1.5 0.4 0.6 0.3 1.1 0.4 1 0.6 1.9 0.4 132 0 133 165 14.7 0 14.9 14.6 08/22/2006 10:50:00 1.4 0.4 1.9 0.7 1.2 0.4 1.9 0.4 1.7 0.3 2.3 1.1 130 5 132 165 14.6 0 14.9 14.4 08/22/2006 11:00:00 1.7 0.6 2.6 0.4 1.5 0.6 2.6 0.4 1.9 0.5 2.6 0.7 135 7 140 165 14.4 0 14.6 14.4 08/22/2006 11:10:00 0.9 0.5 2.3 0.4 0.6 0.4 1.9 0.4 1 0.6 2.3 0.4 16 61 334 165 15.4 0.5 16.3 14.6 08/22/2006 11:20:00 1.2 0.8 3.4 0.4 0.8 0.7 3 0.4 1.4 0.8 3.4 0.4 353 12 350 165 17 0.4 18.2 16.3 08/22/2006 11:30:00 1.5 0.6 3 0.4 1.2 0.6 2.6 0.4 1.8 0.5 3 0.7 344 17 322 165 18.5 0.1 18.8 18 08/22/2006 11:40:00 0.8 0.6 2.3 0.4 0.7 0.5 2.3 0.4 1 0.6 2.6 0.4 353 30 355 165 18.8 0.6 20 18 08/22/2006 11:50:00 2.6 1 4.6 0.4 2.4 1 4.2 0.4 2.6 0.9 4.6 0.4 315 21 325 165 18.7 0.3 19.7 18 08/22/2006 12:00:00 3.5 1.1 5.7 1.1 3.4 1.1 5.7 0.7 3.2 1.1 5.7 0.4 304 21 286 165 17.5 0.3 18.2 16.8 08/22/2006 12:10:00 2.6 0.7 4.9 0.7 2.3 0.8 4.6 0.7 2.4 0.7 5.3 1.1 317 17 314 165 17.2 0 17.4 16.8 08/22/2006 12:20:00 1.6 0.8 3.4 0.4 1.3 0.8 3.8 0.4 1.5 0.7 3.4 0.4 291 36 279 165 17.8 0.4 18.5 17.1 08/22/2006 12:30:00 1 0.6 3.4 0.4 0.8 0.7 3.4 0.4 1 0.6 3 0.4 297 72 290 165 19 0.4 19.7 18.2 08/22/2006 12:40:00 1.6 0.8 3.8 0.4 1.5 0.8 4.2 0.4 1.8 0.9 3 0.4 178 53 165 165 19.4 0.7 20.2 18.2 08/22/2006 12:50:00 0.9 0.6 2.6 0.4 0.8 0.6 2.6 0.4 1.2 0.7 3 0.4 144 56 151 165 18.4 0.3 18.8 17.7 08/22/2006 13:00:00 1.1 0.7 3 0.4 0.9 0.7 3 0.4 1.3 0.8 3.4 0.4 128 47 162 165 18.2 0.1 18.5 17.7 08/22/2006 13:10:00 1.3 0.7 2.6 0.4 1.1 0.7 2.6 0.4 1.8 0.6 3.4 0.4 133 32 141 165 17.1 0 17.7 16.8 08/22/2006 13:20:00 1.7 0.5 3 0.4 1.6 0.6 2.6 0.4 2.1 0.5 3 0.4 131 19 128 165 16.5 0.3 17.1 16.3 08/22/2006 13:30:00 0.4 0.1 1.5 0.4 0.4 0.1 1.1 0.4 0.4 0.2 1.5 0.4 0 47 334 165 17 0.3 17.7 16.6 08/22/2006 13:40:00 0.4 0 0.7 0.4 0.4 0 0.4 0.4 0.4 0.1 1.1 0.4 5 98 325 165 18.2 0.1 18.5 17.7 08/22/2006 13:50:00 1.1 0.5 2.6 0.4 0.9 0.5 2.3 0.4 0.9 0.5 2.6 0.4 294 15 312 165 18.5 0 18.5 18.2 08/22/2006 14:00:00 0.9 0.5 2.6 0.4 0.7 0.5 2.6 0.4 1 0.6 2.6 0.4 208 47 206 165 18.2 0 18.5 17.7 08/22/2006 14:10:00 1.3 0.6 3 0.4 1.3 0.7 2.6 0.4 1.7 0.8 3.4 0.4 139 43 164 165 17.4 0.2 18 16.8 08/22/2006 14:20:00 0.6 0.5 2.6 0.4 0.5 0.4 2.3 0.4 0.8 0.5 2.6 0.4 214 64 328 165 18 0.2 18.2 17.4 08/22/2006 14:30:00 0.7 0.6 3 0.4 0.7 0.5 2.3 0.4 1.2 0.8 3 0.4 79 43 341 165 17.7 0.3 18.2 17.4 08/22/2006 14:40:00 0.9 0.6 2.3 0.4 0.8 0.5 1.9 0.4 1.1 0.6 2.3 0.4 14 66 323 165 17.1 0 17.4 16.8 08/22/2006 14:50:00 2.6 0.5 3.8 1.5 2.6 0.5 3.8 1.5 2.5 0.4 3.8 1.5 324 7 326 165 16.8 0 16.8 16.6 08/22/2006 15:00:00 4.1 0.8 6.8 2.6 4.1 0.8 6.8 2.6 3.2 0.6 5.3 1.9 307 7 304 165 17.3 0.2 17.7 16.8 08/22/2006 15:10:00 5.2 0.6 6.8 3.4 5.2 0.6 6.5 3.4 4.3 0.6 6.1 3 294 6 291 165 17.3 0.1 17.7 17.1 08/22/2006 15:20:00 4.9 0.7 6.5 3 5 0.6 6.5 3.4 4.7 0.6 6.5 3 283 8 288 165 18 0.1 18.2 17.4 08/22/2006 15:30:00 6.1 0.8 8 3.8 6.1 0.8 8 3.8 5.1 1 8 2.6 298 10 292 165 18 0 18.5 18 08/22/2006 15:40:00 5 1.4 8.4 1.5 5.1 1.4 8.4 1.5 3.8 1.3 7.2 1.1 299 16 307 165 18.1 0 18.2 18 08/22/2006 15:50:00 3.8 1.4 7.6 0.7 3.9 1.4 7.6 0.7 2.7 1.3 5.7 0.4 292 18 303 165 18.2 0 18.2 18 08/22/2006 16:00:00 2.5 1.1 7.6 0.4 2.2 1.3 7.2 0.4 2.3 0.8 4.9 0.7 179 86 303 165 18.1 0.2 18.5 17.4 08/22/2006 16:10:00 2 0.9 3.4 0.4 1.8 1 3.4 0.4 2.1 1 3.4 0.4 136 22 137 165 17.4 0.1 17.7 17.1 08/22/2006 16:20:00 2.1 1 3.4 0.4 2 1 3.4 0.4 2.3 1 3.8 0.4 182 61 123 165 17.2 0 17.4 16.8 08/22/2006 16:30:00 3.8 1 6.1 1.1 4.4 1.1 6.5 1.1 4.3 1.1 6.5 1.1 264 17 287 165 17.2 0 17.4 17.1 08/22/2006 16:40:00 5 0.6 6.5 3 5.1 0.6 6.5 3 4.8 0.7 6.5 2.3 283 9 287 165 16.9 0 17.1 16.8 08/22/2006 16:50:00 5.3 0.6 6.8 3.4 5.3 0.6 6.8 3.4 4.7 0.8 6.8 2.3 289 7 276 165 16.6 0 16.8 16.3 08/22/2006 17:00:00 4.4 1.1 6.1 1.1 4.5 1 6.1 0.7 4 0.8 5.7 1.1 307 17 287 165 16.6 0 16.8 16.6 08/22/2006 17:10:00 5.3 1.4 8 1.5 5.4 1.3 8 1.5 4.4 1.3 8 1.1 295 8 292 165 16.4 0.1 16.8 16 08/22/2006 17:20:00 5.4 1.2 8 1.5 5.4 1.1 8 2.3 4.4 1.3 7.6 1.5 293 12 302 165 15.8 0.1 16.3 15.5 08/22/2006 17:30:00 4 1.7 7.2 0.4 4.4 1.8 7.2 0.4 4.1 1.6 7.2 0.7 319 94 280 165 15.3 0.4 16 14.4 08/22/2006 17:40:00 4.3 1.2 8 1.1 4.4 1.2 7.6 0.7 3.3 1 6.1 1.1 313 49 293 165 14.6 0.2 14.9 14.1 08/22/2006 17:50:00 8.1 1.3 10.7 4.9 8.1 1.2 10.3 4.9 7 1.6 10.7 3.8 301 12 308 165 14.8 0.1 15.2 14.6 08/22/2006 18:00:00 8.1 1 10.7 6.1 7.9 1 10.3 5.3 7.4 1 10.3 4.6 319 9 315 165 14.6 0 14.9 14.6 08/22/2006 18:10:00 5.8 1 8 3.4 5.8 1 8 3.4 4.5 1 7.2 1.5 305 13 302 165 14.6 0 14.9 14.6 08/22/2006 18:20:00 7.3 1.1 10.3 4.6 7.2 1.1 9.9 4.6 6.5 1.3 9.9 3.4 314 11 305 165 14.5 0 14.9 14.1 08/22/2006 18:30:00 8.8 1.5 11.8 4.9 8.8 1.6 11.8 4.9 7.9 1.2 11.5 4.9 312 10 305 165 14.1 0.1 15.2 13.5 08/22/2006 18:40:00 11.3 1.2 14.1 8.4 11.2 1.1 14.1 8 10 1.3 13.3 6.8 310 4 312 165 13.7 0 14.4 13.3 08/22/2006 18:50:00 9.2 1.7 13 5.3 9.2 1.7 13 4.9 7.8 1.8 12.6 3.8 306 8 308 165 13.6 0 13.8 13 08/22/2006 19:00:00 6.6 1.5 9.9 1.9 6.6 1.5 9.9 1.5 5.6 1.2 8.8 2.3 307 18 297 165 13.8 0 14.1 13 08/22/2006 19:10:00 6.8 2.4 11.1 1.9 6.8 2.4 11.1 1.1 5.8 2.1 10.3 1.9 311 19 300 165 13.7 0.1 13.8 13 08/22/2006 19:20:00 8.9 1.2 11.5 5.7 8.8 1.2 11.5 6.1 7.8 1.1 11.1 5.3 311 7 308 165 13.3 0 13.5 12.5 08/22/2006 19:30:00 8.7 1.1 11.5 5.3 8.6 1.1 11.5 5.7 7.7 1.2 10.7 3 314 8 310 165 13.3 0 13.5 12.5 08/22/2006 19:40:00 7.3 1.4 10.3 4.6 7.3 1.3 10.3 4.6 6.4 1.3 9.9 3.4 313 8 309 165 13.5 0.1 13.5 13.3 08/22/2006 19:50:00 7.7 1.1 10.3 3.8 7.7 1.1 9.9 4.2 6.5 1 9.1 3.8 309 6 310 165 13.5 0 13.5 13.3 08/22/2006 20:00:00 6.8 1.1 9.5 3.8 6.7 1.1 9.1 3.8 5.6 1.1 8.4 3 311 11 310 165 13.1 0.1 13.5 13 08/22/2006 20:10:00 4.6 1 7.2 1.9 4.6 1 7.2 1.9 4.2 0.9 6.8 2.6 317 11 311 165 12.7 0.2 13.3 12.2 08/22/2006 20:20:00 3.7 1 5.7 1.5 3.6 1 5.7 1.1 3.6 0.8 5.3 1.9 349 32 307 165 12.1 0 12.2 11.9 08/22/2006 20:30:00 3.9 0.7 6.1 2.3 3 1 6.1 1.5 4.2 0.6 6.1 2.3 5 13 334 165 11.9 0 11.9 11.7 08/22/2006 20:40:00 3.2 1.3 6.1 1.1 3.2 1.3 6.5 1.1 3.2 1.3 6.1 1.1 322 26 331 165 11.8 0 12.2 11.7 08/22/2006 20:50:00 2.7 1.1 5.7 0.4 2.9 1.1 5.3 0.4 2.6 1 5.3 0.7 302 19 307 165 11.7 0 11.9 11.4 08/22/2006 21:00:00 4.5 1.2 7.6 2.3 4.6 1.2 7.6 2.3 3.9 1 7.6 2.3 310 9 313 165 11.5 0.1 11.9 11.1 08/22/2006 21:10:00 6.1 0.9 8.8 4.6 6.1 0.9 8.8 4.6 5.5 1 8.4 3 312 9 309 165 11.7 0.1 11.9 11.4 08/22/2006 21:20:00 7.7 1 9.9 5.3 7.7 0.9 9.9 5.3 6.5 0.9 8.4 4.2 309 5 301 165 11.7 0.2 11.9 11.4 08/22/2006 21:30:00 7.1 0.6 8.8 5.3 7.1 0.6 8.8 5.3 5.7 0.8 8.4 3.4 307 5 315 165 11.5 0 11.9 11.1 08/22/2006 21:40:00 5.5 0.8 7.6 3.4 5.6 0.8 7.6 3.8 4.6 0.6 6.5 3.4 311 12 307 165 11.2 0.2 11.7 10.9 08/22/2006 21:50:00 6 1.1 8.4 3.4 6 1.1 8.4 3.8 5.5 1.1 8.4 3 318 10 314 165 11.1 0.2 11.7 10.9 08/22/2006 22:00:00 7.6 1.1 11.1 5.3 7.5 1.1 10.7 4.9 6.8 1 9.5 4.6 313 8 301 165 11.7 0.3 12.2 11.1 08/22/2006 22:10:00 6.6 1.1 9.9 4.6 6.6 1.1 9.5 4.6 5.5 1.2 8.8 3.4 308 6 316 165 11.9 0.2 12.5 11.4 08/22/2006 22:20:00 7 0.7 8.8 5.3 6.9 0.7 8.8 5.7 5.6 1 8.4 3.4 305 6 312 165 11.9 0.2 12.2 11.1 08/22/2006 22:30:00 7.3 1 9.1 4.6 7.3 0.9 9.1 4.6 5.5 0.9 8.8 3.8 300 5 298 165 11.9 0.2 12.5 11.4 08/22/2006 22:40:00 6.2 1.1 8.8 3 6.2 1.1 8.4 3 4.9 1.2 8.8 2.6 298 8 293 165 12 0.2 12.5 11.4 08/22/2006 22:50:00 6 0.9 7.6 3.4 6 0.9 7.6 3.8 4.8 0.9 7.6 3 296 8 297 165 12.1 0.1 12.5 11.7 08/22/2006 23:00:00 6.3 0.8 8.8 4.2 6.3 0.8 8.8 4.2 5 0.8 8.4 3 301 8 309 165 12.1 0 12.5 11.4 08/22/2006 23:10:00 4.8 0.8 6.5 2.6 4.8 0.7 6.5 2.6 4.1 0.7 6.5 2.3 302 11 305 165 12.1 0 12.2 11.4 08/22/2006 23:20:00 3.7 0.7 5.3 2.3 3.8 0.7 5.3 2.3 3.5 0.8 5.7 2.3 295 11 285 165 12.2 0 12.5 11.7 08/22/2006 23:30:00 1.4 0.5 2.6 0.4 1.5 0.6 2.6 0.4 2.1 0.5 3 0.7 287 11 317 165 12.3 0.1 12.5 11.7 08/22/2006 23:40:00 1.1 0.6 2.6 0.4 1.2 0.6 3 0.4 2 0.5 3.8 0.7 282 11 276 165 12.3 0 12.5 12.2 08/22/2006 23:50:00 0.6 0.4 2.3 0.4 0.5 0.4 2.3 0.4 0.4 0.1 1.1 0.4 71 45 82 165 12.5 0 12.7 12.5 08/23/2006 00:00:00 0.4 0.1 1.1 0.4 0.4 0 0.4 0.4 0.5 0.3 1.5 0.4 332 39 3 165 12.7 0 13 12.5 08/23/2006 00:10:00 0.4 0.1 1.1 0.4 0.4 0 0.7 0.4 0.5 0.3 1.9 0.4 183 43 205 165 12.7 0 13 12.5 08/23/2006 00:20:00 0.7 0.7 2.6 0.4 0.7 0.7 2.6 0.4 0.8 0.7 3 0.4 201 64 287 165 12.6 0 12.7 12.5 08/23/2006 00:30:00 2.6 0.6 4.2 1.1 2.6 0.6 4.2 1.1 2.5 0.6 4.2 1.1 297 10 283 165 12.3 0.1 12.5 11.9 08/23/2006 00:40:00 2.5 0.6 4.2 1.5 2.6 0.6 4.2 1.5 2.4 0.5 4.2 1.5 302 11 296 165 11.9 0.1 12.5 11.7 08/23/2006 00:50:00 1.3 0.8 3.4 0.4 1.3 0.8 3 0.4 1.9 0.9 3.4 0.4 305 22 287 165 12.1 0.2 12.7 11.7 08/23/2006 01:00:00 1.3 0.6 3 0.4 1 0.6 2.6 0.4 1.4 0.4 2.6 0.4 342 27 331 165 12.5 0 12.7 12.2 08/23/2006 01:10:00 1.5 0.8 4.2 0.4 1.4 0.8 4.2 0.4 1.7 0.6 3.8 0.4 328 15 335 165 12.7 0.1 13 12.2 08/23/2006 01:20:00 3.1 0.4 4.2 1.9 3 0.5 4.2 1.5 3.1 0.4 4.2 2.3 323 16 310 165 12.6 0 12.7 11.9 08/23/2006 01:30:00 3.7 0.6 5.3 2.3 3.6 0.6 4.9 1.9 3.5 0.6 4.9 2.3 323 9 334 165 12.1 0 12.7 11.7 08/23/2006 01:40:00 2.7 0.5 4.2 1.9 2.7 0.5 4.6 1.9 2.6 0.5 3.8 1.1 318 8 328 165 11.7 0.1 12.2 11.1 08/23/2006 01:50:00 1.5 0.4 2.3 0.4 1.5 0.4 2.3 0.4 1.6 0.4 2.3 0.7 293 13 324 165 11.5 0.2 12.2 11.1 08/23/2006 02:00:00 1.4 0.4 2.6 0.4 1.5 0.5 3 0.4 1.9 0.5 3 0.7 293 12 295 165 12.2 0.1 12.5 11.7 08/23/2006 02:10:00 2.2 0.5 3.4 0.7 2.3 0.5 3 0.7 2.3 0.4 3 1.1 312 7 315 165 12.3 0.1 12.7 11.9 08/23/2006 02:20:00 2.9 0.5 3.8 1.5 2.8 0.5 3.8 1.5 3 0.5 4.2 1.9 327 12 310 165 11.8 0.1 12.2 11.4 08/23/2006 02:30:00 1.7 0.3 2.6 1.1 1.3 0.6 2.6 0.4 2 0.3 2.6 1.5 352 9 341 165 11.8 0.1 12.2 11.4 08/23/2006 02:40:00 1.1 0.6 2.3 0.4 0.5 0.3 1.5 0.4 1.5 0.6 2.6 0.4 2 2 0 165 11.9 0 12.2 11.7 08/23/2006 02:50:00 0.4 0.1 0.7 0.4 0.4 0 0.4 0.4 0.5 0.3 1.1 0.4 2 0 2 165 11.7 0.1 11.9 11.4 08/23/2006 03:00:00 0.4 0 0.7 0.4 0.4 0 0.4 0.4 0.4 0.2 1.1 0.4 357 8 344 165 11.7 0.2 12.2 11.4 08/23/2006 03:10:00 0.4 0.2 1.1 0.4 0.4 0 0.7 0.4 0.4 0.2 1.1 0.4 344 0 344 165 12 0.1 12.2 11.7 08/23/2006 03:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0.1 1.1 0.4 57 24 165 165 12.1 0.3 12.5 11.7 08/23/2006 03:30:00 0.9 0.5 1.9 0.4 0.8 0.5 1.9 0.4 1.3 0.6 2.3 0.4 160 38 134 165 12.1 0.3 12.5 11.1 08/23/2006 03:40:00 1.1 0.6 2.6 0.4 1.1 0.7 3 0.4 1.3 0.7 2.6 0.4 304 94 268 165 11.5 0.4 12.5 10.9 08/23/2006 03:50:00 1.4 0.6 3.4 0.4 1.3 0.7 3.4 0.4 1.7 0.6 3 0.4 280 5 289 165 12.5 0 12.7 11.9 08/23/2006 04:00:00 2.1 0.5 3.4 1.5 2.1 0.5 3.4 1.5 2 0.4 3 1.1 291 0 289 165 12.3 0 12.7 11.9 08/23/2006 04:10:00 1.8 0.3 2.3 1.1 1.9 0.3 2.6 1.1 1.6 0.3 2.3 0.7 294 2 291 165 12.3 0.1 12.7 11.9 08/23/2006 04:20:00 1.6 0.2 2.3 1.1 1.6 0.2 2.3 1.1 1.6 0.3 2.3 0.7 295 0 295 165 12.5 0 12.7 11.9 08/23/2006 04:30:00 0.8 0.4 1.9 0.4 0.6 0.4 1.9 0.4 1.1 0.4 1.9 0.4 317 10 295 165 12.2 0.3 12.7 11.4 08/23/2006 04:40:00 0.4 0.1 0.7 0.4 0.4 0 0.4 0.4 0.5 0.2 1.1 0.4 324 0 325 165 11.6 0.3 12.2 11.1 08/23/2006 04:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 324 0 165 165 11.3 0.2 11.7 10.9 08/23/2006 05:00:00 0.7 0.4 1.5 0.4 0.4 0.2 1.1 0.4 1 0.5 1.9 0.4 359 32 24 165 11.4 0.2 11.7 10.9 08/23/2006 05:10:00 1 0.2 1.5 0.7 0.5 0.2 1.1 0.4 1.4 0.2 1.9 1.1 24 4 25 165 11.5 0.2 11.9 10.9 08/23/2006 05:20:00 0.8 0.2 1.1 0.4 0.4 0.1 0.7 0.4 1.4 0.2 1.9 0.7 21 0 22 165 11.8 0.3 12.2 10.9 08/23/2006 05:30:00 0.5 0.2 0.7 0.4 0.4 0 0.4 0.4 0.7 0.3 1.1 0.4 21 0 22 165 12.1 0.2 12.5 11.4 08/23/2006 05:40:00 0.4 0 0.7 0.4 0.4 0 0.4 0.4 0.4 0.2 1.1 0.4 39 35 114 165 11.8 0.2 12.5 11.4 08/23/2006 05:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.7 0.4 113 0 165 165 11.7 0 12.2 11.4 08/23/2006 06:00:00 0.4 0.1 0.7 0.4 0.4 0 0.4 0.4 0.4 0.2 1.1 0.4 122 3 115 165 11.6 0 12.2 11.4 08/23/2006 06:10:00 0.6 0.3 1.1 0.4 0.4 0 0.4 0.4 0.8 0.3 1.5 0.4 144 11 143 165 11.7 0.1 12.2 11.4 08/23/2006 06:20:00 0.4 0.1 0.7 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 151 0 151 165 12.5 0.2 13 11.9 08/23/2006 06:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 151 0 165 165 13.3 0.3 13.8 12.5 08/23/2006 06:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 151 0 165 165 13.9 0.3 14.6 13.3 08/23/2006 06:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.7 0.4 151 0 165 165 14.8 0 15.2 14.4 08/23/2006 07:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 151 0 165 165 15.4 0.4 16.3 14.6 08/23/2006 07:10:00 0.4 0.1 0.7 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 142 5 147 165 16.2 0.3 16.8 15.5 08/23/2006 07:20:00 0.4 0 0.7 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 139 0 139 165 15.1 0.1 15.7 14.6 08/23/2006 07:30:00 0.4 0 0.7 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 139 0 139 165 14.9 0.2 15.2 14.4 08/23/2006 07:40:00 0.4 0 0.4 0.4 0.4 0 0.7 0.4 0.4 0.1 1.1 0.4 139 0 165 165 14.8 0.1 15.2 14.6 08/23/2006 07:50:00 0.5 0.2 1.1 0.4 0.4 0.1 1.1 0.4 0.4 0 0.7 0.4 148 9 145 165 14.8 0.2 15.5 14.1 08/23/2006 08:00:00 1.2 0.6 2.6 0.4 1.1 0.6 2.6 0.4 1.3 0.7 2.6 0.4 156 27 126 165 14.5 0.5 15.5 13.5 08/23/2006 08:10:00 1.1 0.6 2.6 0.4 1.1 0.7 2.6 0.4 1.2 0.7 3 0.4 155 12 130 165 14.1 0.3 14.9 13.5 08/23/2006 08:20:00 1.1 0.7 2.6 0.4 1.2 0.7 2.6 0.4 1.1 0.7 2.6 0.4 156 23 165 165 14.6 0.1 15.2 14.4 08/23/2006 08:30:00 1.8 0.6 3 0.4 1.8 0.6 3 0.7 1.8 0.8 3.4 0.4 163 19 141 165 14.6 0.2 15.2 14.4 08/23/2006 08:40:00 2.3 0.5 3.4 1.1 2.2 0.5 3.4 1.1 2.4 0.4 3.4 1.5 172 17 136 165 14.2 0.4 14.9 13.5 08/23/2006 08:50:00 2.6 0.4 3.8 1.9 2.6 0.4 3.8 1.9 2.7 0.4 3.8 1.9 179 10 174 165 13.5 0 13.5 13.3 08/23/2006 09:00:00 3.3 0.6 4.6 1.9 3.3 0.5 4.6 1.9 3.3 0.5 4.6 2.3 182 8 172 165 13.5 0 13.8 13.3 08/23/2006 09:10:00 3.6 0.4 4.2 2.3 3.5 0.4 4.2 2.3 3.5 0.5 4.6 1.9 177 9 179 165 13.9 0.1 14.1 13.5 08/23/2006 09:20:00 3.2 0.4 4.2 1.9 3.2 0.4 4.2 1.9 3.3 0.4 4.6 2.3 172 7 181 165 13.7 0 14.4 13.3 08/23/2006 09:30:00 3 0.5 4.2 1.5 3.1 0.5 4.2 1.5 3.2 0.5 4.2 1.9 160 9 146 165 13.9 0 14.1 13.3 08/23/2006 09:40:00 3.2 0.5 4.2 1.9 3.2 0.4 4.6 2.3 3.4 0.4 4.2 2.3 156 7 146 165 14.1 0 14.4 13.5 08/23/2006 09:50:00 3 0.4 4.2 1.9 3.1 0.4 4.6 2.3 3.2 0.4 4.2 2.3 151 9 148 165 14.4 0 14.6 14.1 08/23/2006 10:00:00 3.4 0.5 4.6 1.9 3.5 0.5 4.9 1.9 3.6 0.5 4.9 2.3 153 11 151 165 14.6 0.1 14.9 14.4 08/23/2006 10:10:00 3.9 1 6.1 1.9 3.9 1.1 6.5 1.9 4.1 1 6.5 2.3 149 15 145 165 15.2 0 15.5 14.9 08/23/2006 10:20:00 3.9 0.8 5.3 1.9 3.8 0.8 5.7 1.5 4 0.7 5.7 2.3 156 13 127 165 15 0.1 15.5 14.6 08/23/2006 10:30:00 4.5 0.5 5.7 3.4 4.4 0.5 5.7 3 4.6 0.5 5.7 3.4 153 10 129 165 14.8 0 15.2 14.6 08/23/2006 10:40:00 4.7 0.5 6.1 3.8 4.7 0.4 5.7 3.8 4.9 0.5 6.5 3.8 148 9 138 165 15 0.2 15.5 14.6 08/23/2006 10:50:00 4.7 0.5 5.7 3 4.6 0.5 5.7 3 4.8 0.5 5.7 3.8 150 6 148 165 15.2 0 15.5 15.2 08/23/2006 11:00:00 5.1 0.6 6.5 2.6 5.1 0.6 6.5 2.6 5.3 0.6 6.8 3 153 8 158 165 15.2 0 15.7 15.2 08/23/2006 11:10:00 4.5 0.6 6.1 3 4.5 0.6 6.1 2.6 4.7 0.6 7.2 3.4 144 10 150 165 15.4 0 16 15.2 08/23/2006 11:20:00 4.1 0.6 6.1 2.6 4.1 0.6 6.1 2.6 4.3 0.7 6.1 2.3 144 12 124 165 15.2 0.2 16.3 14.9 08/23/2006 11:30:00 4.2 1 6.5 2.3 4.2 1 6.5 2.3 4.5 1 6.5 2.6 146 10 156 165 15.5 0 16 15.2 08/23/2006 11:40:00 4 0.9 6.5 1.1 4.1 0.9 6.8 1.5 4.3 0.8 6.8 2.3 142 10 136 165 15.3 0 15.7 15.2 08/23/2006 11:50:00 4.1 0.7 6.1 2.3 4.2 0.7 6.1 2.6 4.4 0.6 6.1 3 143 10 149 165 15.5 0 15.7 15.5 08/23/2006 12:00:00 4.9 0.8 7.2 2.3 4.9 0.8 7.2 2.3 5.2 0.8 7.2 2.6 142 9 132 165 15.4 0.1 16 15.2 08/23/2006 12:10:00 5.2 0.7 7.2 3.4 5.2 0.8 7.2 3.4 5.4 0.7 7.6 3.4 138 8 135 165 15.5 0 16 15.2 08/23/2006 12:20:00 4.9 0.8 7.2 3 4.9 0.8 7.6 3 5 0.8 7.2 3 134 9 130 165 15.3 0.1 15.7 15.2 08/23/2006 12:30:00 5.2 0.8 7.2 2.6 5.2 0.8 7.6 2.6 5.3 0.8 7.6 3 136 10 122 165 15.2 0 15.7 14.9 08/23/2006 12:40:00 5.2 0.7 6.8 3.4 5.2 0.7 6.8 3.4 5.4 0.7 6.8 3.4 136 9 136 165 15.2 0.2 15.7 14.9 08/23/2006 12:50:00 5.5 0.7 7.2 3.4 5.5 0.7 7.6 3.4 5.5 0.8 7.6 3.4 127 7 143 165 15 0 15.2 14.9 08/23/2006 13:00:00 5.6 0.8 7.6 3.4 5.7 0.8 8.8 3.4 5.8 0.8 8.4 3.8 134 9 120 165 15 0 15.5 14.6 08/23/2006 13:10:00 5.1 0.8 8 2.6 5.2 0.8 7.6 3 5.3 0.8 7.2 3 137 11 133 165 15 0 15.5 14.9 08/23/2006 13:20:00 5.6 0.6 7.2 4.2 5.6 0.6 7.2 4.2 5.7 0.7 7.2 3.4 140 9 141 165 15 0.2 15.7 14.6 08/23/2006 13:30:00 5.9 0.8 8 4.6 5.9 0.8 8.4 4.6 6 0.8 8.4 3.4 135 9 138 165 14.5 0 14.9 14.4 08/23/2006 13:40:00 5.9 0.9 8 3 6 0.9 8.4 3 5.9 0.9 7.6 3.8 135 10 123 165 14.4 0 14.9 14.1 08/23/2006 13:50:00 6.7 0.9 9.1 4.6 6.8 1 9.9 4.6 6.7 1 9.5 4.2 133 9 128 165 14.4 0 14.9 14.1 08/23/2006 14:00:00 6.7 0.8 8.8 4.9 6.8 0.9 9.1 4.6 6.7 0.9 8.8 4.6 126 9 128 165 14.4 0.2 15.2 13.8 08/23/2006 14:10:00 5.8 1 8.8 3 6 1 8.8 3.4 5.9 0.9 8.8 3.4 126 11 115 165 14.1 0 14.4 14.1 08/23/2006 14:20:00 5.3 0.8 7.6 3 5.4 0.8 7.6 3.4 5.4 0.6 7.2 3.8 138 8 136 165 14.4 0.3 15.2 14.1 08/23/2006 14:30:00 6 0.7 7.6 3.8 6.1 0.7 7.6 4.2 5.9 0.7 7.6 3.8 137 10 144 165 14.6 0 15.2 14.4 08/23/2006 14:40:00 5.6 0.8 7.6 3.4 5.7 0.8 7.2 3.8 5.7 0.8 7.2 3.4 136 11 133 165 14.8 0.1 15.5 14.6 08/23/2006 14:50:00 5.7 0.8 7.6 4.2 5.8 0.7 8 4.2 5.8 0.7 8 3.8 139 9 138 165 14.8 0.1 15.5 14.4 08/23/2006 15:00:00 5.9 0.7 8 4.6 6 0.7 8.4 4.6 5.9 0.7 8 4.2 137 8 129 165 14.8 0.3 15.7 14.4 08/23/2006 15:10:00 6 0.7 8 4.2 6.1 0.7 8 4.6 6 0.8 8.8 4.2 135 9 144 165 14.4 0 14.9 14.1 08/23/2006 15:20:00 6.1 0.7 8 4.2 6.2 0.7 8 4.2 6.1 0.7 8 4.2 136 10 128 165 14.3 0.2 14.6 14.1 08/23/2006 15:30:00 6.5 0.7 8.8 4.6 6.6 0.6 8.4 4.9 6.5 0.7 8.4 4.6 136 8 141 165 13.9 0 14.4 13.8 08/23/2006 15:40:00 6.8 0.8 8.8 4.9 6.9 0.7 8.8 4.9 6.9 0.7 8.8 5.3 140 9 139 165 14.2 0 14.6 13.8 08/23/2006 15:50:00 6.9 0.7 8.8 4.9 6.9 0.7 8.8 4.9 6.9 0.8 9.1 4.9 140 8 146 165 14.4 0 14.6 14.4 08/23/2006 16:00:00 7.2 0.7 9.1 5.3 7.2 0.6 9.1 5.3 7.3 0.7 9.1 5.3 145 6 148 165 13.9 0.3 14.6 13.5 08/23/2006 16:10:00 7.5 0.8 9.5 5.7 7.5 0.7 9.5 5.7 7.5 0.7 9.5 5.7 143 6 150 165 13.6 0 13.8 13.5 08/23/2006 16:20:00 7.3 0.7 9.1 5.7 7.4 0.6 9.1 5.7 7.2 0.7 9.1 5.7 142 6 133 165 14.3 0.2 14.6 13.8 08/23/2006 16:30:00 7.3 0.8 9.5 5.3 7.4 0.8 9.5 5.3 7.3 0.7 9.1 5.7 141 7 151 165 14.2 0.1 14.6 14.1 08/23/2006 16:40:00 7.5 0.7 9.1 5.3 7.5 0.7 9.1 5.3 7.5 0.7 9.1 5.7 143 6 148 165 13.9 0 14.4 13.5 08/23/2006 16:50:00 7.3 0.7 9.5 5.7 7.4 0.7 9.1 5.7 7.3 0.6 9.1 5.7 140 6 135 165 13.8 0 13.8 13.5 08/23/2006 17:00:00 7.5 0.7 9.1 5.3 7.6 0.7 9.1 5.7 7.4 0.6 8.8 5.7 139 6 145 165 13.7 0.1 14.1 13.3 08/23/2006 17:10:00 7.6 0.7 9.1 5.7 7.6 0.7 9.5 5.7 7.5 0.7 9.1 5.3 139 6 150 165 13.5 0 13.8 13.3 08/23/2006 17:20:00 7.3 0.8 9.5 5.3 7.4 0.8 9.5 5.3 7.2 0.8 9.9 4.9 139 6 139 165 13.5 0 13.8 13.3 08/23/2006 17:30:00 7.4 0.9 9.9 5.3 7.4 0.9 9.5 5.7 7.2 0.9 9.5 5.3 141 8 144 165 13.1 0.1 13.5 12.7 08/23/2006 17:40:00 6 0.9 8.4 3.8 6.1 0.8 8.4 3.8 5.9 0.9 8.8 4.2 141 8 144 165 12.9 0 13 12.2 08/23/2006 17:50:00 5.3 0.8 7.2 3.4 5.3 0.8 7.6 3.4 5.1 0.7 7.2 3.8 142 8 145 165 12.5 0 13 12.2 08/23/2006 18:00:00 4.4 1.1 6.8 1.9 4.5 1.1 6.5 1.9 4.4 1.1 6.8 1.9 143 12 133 165 12.6 0 12.7 12.5 08/23/2006 18:10:00 4.5 0.9 6.8 2.3 4.6 0.8 6.8 2.6 4.5 0.9 7.2 2.3 136 12 146 165 12.5 0 12.7 12.5 08/23/2006 18:20:00 4.1 0.6 6.1 2.6 4.2 0.5 6.1 2.6 4.2 0.5 5.7 2.6 138 8 136 165 12.3 0 12.7 11.9 08/23/2006 18:30:00 3.3 1 5.3 0.4 3.4 0.9 5.7 0.4 3.4 0.7 5.3 1.1 142 17 159 165 11.9 0.1 12.2 11.4 08/23/2006 18:40:00 3.4 0.9 6.1 1.5 3.6 0.8 6.1 1.9 3.5 0.7 5.7 2.3 143 15 129 165 10.6 0.3 11.7 9.6 08/23/2006 18:50:00 3.1 0.6 4.9 1.5 3.3 0.6 4.9 1.9 3.1 0.5 4.2 1.9 145 11 132 165 9.9 0.2 10.6 9.6 08/23/2006 19:00:00 4.6 0.5 6.5 3 4.7 0.5 6.5 3.4 4.4 0.5 5.7 3 139 6 148 165 9.7 0 9.8 9.6 08/23/2006 19:10:00 5.8 0.7 7.6 4.6 5.9 0.7 7.6 4.6 5.6 0.6 7.2 4.2 142 4 135 165 9.8 0 10.1 9.6 08/23/2006 19:20:00 6.5 0.7 8 4.6 6.5 0.7 8.4 4.9 6.4 0.6 8 4.9 143 5 147 165 10 0.1 10.3 9.6 08/23/2006 19:30:00 5.9 0.7 8 4.2 6 0.6 8 4.2 5.9 0.6 7.6 4.6 139 7 136 165 10.1 0 10.3 10.1 08/23/2006 19:40:00 5.8 0.6 7.6 4.6 5.9 0.5 7.6 4.9 5.7 0.5 7.2 4.6 131 8 133 165 10 0 10.3 9.8 08/23/2006 19:50:00 5.7 0.6 7.6 4.6 5.9 0.6 7.6 4.6 5.9 0.6 7.2 4.6 135 8 140 165 10 0 10.3 9.8 08/23/2006 20:00:00 5.9 0.6 7.2 4.6 6 0.6 7.2 4.6 6.1 0.6 7.6 4.6 143 6 148 165 9.9 0 10.3 9.6 08/23/2006 20:10:00 5.5 0.8 6.8 3.8 5.6 0.8 6.8 3.8 5.6 0.9 7.6 3.8 147 5 137 165 9.8 0 10.3 9.6 08/23/2006 20:20:00 5.7 0.7 6.8 3.8 5.8 0.7 7.2 3.8 5.9 0.8 7.2 3.8 143 6 145 165 9.8 0 10.1 9.6 08/23/2006 20:30:00 7.1 1 9.1 4.9 7.2 1 9.1 4.9 7.2 1.2 9.1 3.4 145 4 147 165 9.8 0 9.8 9.3 08/23/2006 20:40:00 7.5 0.7 9.1 5.7 7.5 0.7 8.8 5.7 7.7 0.7 9.5 6.1 148 5 150 165 9.8 0 10.3 9.3 08/23/2006 20:50:00 6.6 0.4 7.6 5.7 6.6 0.4 7.6 5.7 6.8 0.4 7.6 6.1 154 3 152 165 10 0.1 10.3 9.6 08/23/2006 21:00:00 6.5 0.4 7.6 5.7 6.5 0.4 7.2 5.7 6.8 0.4 7.6 6.1 154 3 155 165 9.9 0.1 10.3 9.6 08/23/2006 21:10:00 6.9 0.4 8 5.7 6.9 0.4 8 5.7 7.1 0.4 8 6.1 156 3 158 165 9.9 0.2 10.6 9.6 08/23/2006 21:20:00 7 0.7 8.4 5.3 7 0.7 8.4 5.7 7 0.7 8.4 5.3 153 3 153 165 10 0.2 10.3 9.6 08/23/2006 21:30:00 7.2 0.8 9.1 5.3 7.2 0.7 9.1 5.3 7.2 0.9 9.1 5.3 152 5 154 165 10 0.2 10.3 9.6 08/23/2006 21:40:00 8.1 0.4 9.1 6.8 8.1 0.4 9.1 6.8 8.2 0.5 9.1 7.2 156 3 159 165 9.9 0.2 10.3 9.6 08/23/2006 21:50:00 7.9 0.5 9.1 6.5 7.8 0.5 9.1 6.5 8.1 0.5 9.1 6.8 157 4 156 165 10 0 10.6 9.3 08/23/2006 22:00:00 6.5 0.4 7.6 5.3 6.5 0.4 7.6 5.7 6.7 0.4 8 5.7 158 2 162 165 10 0 10.3 9.6 08/23/2006 22:10:00 6.4 0.3 7.2 5.7 6.4 0.2 7.2 5.7 6.5 0.3 7.2 5.7 154 4 157 165 10.1 0 10.3 9.6 08/23/2006 22:20:00 6.2 0.5 7.2 4.9 6.3 0.4 7.6 5.3 6.2 0.5 7.6 4.6 141 4 138 165 10.1 0 10.3 9.3 08/23/2006 22:30:00 5.6 0.3 6.5 4.6 5.7 0.3 6.5 4.9 5.6 0.4 6.5 3.8 141 3 143 165 10 0 10.6 9.3 08/23/2006 22:40:00 5.2 0.3 6.1 4.2 5.3 0.3 6.1 4.6 5.3 0.3 6.1 4.2 138 4 143 165 9.9 0 10.6 9.6 08/23/2006 22:50:00 5.2 0.4 6.1 3.8 5.3 0.4 6.1 3.8 5.3 0.5 6.5 3.8 143 3 145 165 9.9 0 9.8 9.6 08/23/2006 23:00:00 4.9 0.4 5.7 4.2 4.9 0.4 5.7 4.2 5 0.4 5.7 3.4 143 3 143 165 9.9 0 10.1 9.6 08/23/2006 23:10:00 5.2 0.4 6.1 4.2 5.1 0.4 6.5 4.2 5.3 0.4 6.1 4.2 146 4 151 165 9.9 0 9.8 9.6 08/23/2006 23:20:00 4.4 0.3 5.3 3.4 4.5 0.3 5.3 3.4 4.5 0.4 5.3 3.4 145 4 150 165 9.9 0 10.1 9.6 08/23/2006 23:30:00 4.5 0.4 5.3 3.8 4.5 0.4 5.7 3.4 4.6 0.5 5.7 3.4 145 4 150 165 9.8 0 9.8 9.6 08/23/2006 23:40:00 4.4 0.3 5.3 3.8 4.4 0.3 4.9 3.4 4.6 0.3 5.3 3.8 150 3 148 165 9.8 0 9.8 9.6 08/23/2006 23:50:00 4.8 0.3 5.3 4.2 4.7 0.3 5.3 4.2 5 0.4 5.7 3.8 152 3 154 165 9.7 0 9.8 9.3 08/24/2006 00:00:00 4.1 0.3 4.9 3 4 0.3 4.6 3 4.1 0.3 4.9 3.4 146 5 135 165 9.7 0 10.1 9.3 08/24/2006 00:10:00 3.5 0.4 4.6 2.6 3.5 0.4 4.6 2.3 3.6 0.4 4.6 2.6 140 5 145 165 9.7 0 9.8 9.3 08/24/2006 00:20:00 3.5 0.4 4.2 2.3 3.5 0.4 4.2 1.9 3.6 0.4 4.6 2.3 135 6 135 165 9.9 0 10.1 9.6 08/24/2006 00:30:00 4.1 0.2 4.6 3.4 4.2 0.2 4.6 3.4 4.2 0.3 4.9 3.4 132 3 137 165 10 0.1 10.1 9.6 08/24/2006 00:40:00 4.4 0.2 4.9 3.8 4.5 0.2 4.9 3.8 4.6 0.2 5.3 4.2 137 2 135 165 10 0 10.6 9.6 08/24/2006 00:50:00 4.7 0.3 5.3 4.2 4.8 0.3 5.3 4.2 4.8 0.3 5.3 4.2 128 3 126 165 10 0.1 10.3 9.6 08/24/2006 01:00:00 4.9 0.3 5.7 3.8 5 0.3 5.7 4.2 4.8 0.3 5.3 4.2 127 2 128 165 10 0 10.1 9.6 08/24/2006 01:10:00 4.3 0.6 6.1 3 4.4 0.6 6.1 3.4 4.2 0.6 5.7 3 118 3 119 165 9.8 0 10.1 9.3 08/24/2006 01:20:00 5.6 0.4 6.5 4.6 5.8 0.4 6.8 4.6 5.6 0.4 6.5 4.6 112 5 121 165 9.7 0.1 9.8 9.3 08/24/2006 01:30:00 6.4 0.4 8 5.3 6.6 0.4 7.6 5.7 6.3 0.4 7.6 4.6 116 3 113 165 9.6 0.2 9.8 9 08/24/2006 01:40:00 6.9 0.3 7.6 5.7 7.1 0.3 7.6 5.7 6.8 0.5 7.6 4.9 108 4 111 165 9.6 0.1 9.8 9 08/24/2006 01:50:00 7.2 0.6 8.4 4.9 7.4 0.7 8.8 4.6 6.4 0.9 8.4 4.2 103 4 102 165 9.5 0.1 9.6 9 08/24/2006 02:00:00 8.3 0.5 9.1 6.1 8.5 0.5 9.5 6.5 7.4 0.9 9.1 4.6 103 3 102 165 9.6 0.1 9.8 9 08/24/2006 02:10:00 8.7 0.5 9.9 6.5 9 0.5 9.9 6.5 8.1 0.8 9.1 5.7 103 3 98 165 9.8 0 10.1 9.3 08/24/2006 02:20:00 8.9 0.4 9.5 6.8 9.2 0.4 9.9 7.2 8.2 0.8 9.5 5.7 101 3 102 165 10 0 10.3 9.6 08/24/2006 02:30:00 9 0.6 10.7 6.1 9.3 0.7 10.7 6.5 8.4 0.8 10.3 6.5 99 5 103 165 10.1 0.1 10.3 9.6 08/24/2006 02:40:00 9.3 0.6 10.7 7.2 9.5 0.7 11.1 7.6 8.6 0.8 10.3 6.1 99 5 101 165 10.1 0.1 10.3 9.6 08/24/2006 02:50:00 9.5 0.8 11.5 6.8 9.7 0.8 11.5 7.2 8.8 1 11.1 6.1 100 5 105 165 10.1 0.1 10.3 9.6 08/24/2006 03:00:00 9.8 0.6 11.5 6.8 10.1 0.6 11.5 7.2 9.2 0.8 11.1 6.5 98 4 99 165 10.1 0.1 10.3 9.8 08/24/2006 03:10:00 9.9 0.6 11.1 8 10.2 0.7 11.8 6.8 9.1 0.9 11.1 6.5 98 5 98 165 10.1 0.1 10.3 9.8 08/24/2006 03:20:00 10.4 0.7 11.8 7.2 10.7 0.7 11.8 7.6 9.4 1 11.5 6.1 102 5 104 165 10.2 0 10.3 9.8 08/24/2006 03:30:00 10.5 0.8 11.8 7.6 10.8 0.8 12.2 7.6 9.5 1 11.5 6.8 99 5 97 165 10.3 0.1 10.6 9.6 08/24/2006 03:40:00 10.8 1 13.3 7.6 11 1 13.7 7.6 9.9 1.2 12.6 6.1 99 5 102 165 10.1 0.1 10.3 9.6 08/24/2006 03:50:00 12.2 0.9 13.7 9.1 12.4 1 14.1 8.8 11.1 1.1 13.3 7.6 95 5 94 165 10 0 10.3 9.3 08/24/2006 04:00:00 11.9 0.9 13.7 9.1 12.2 0.9 14.5 9.5 11 1 13.3 7.6 94 5 95 165 9.8 0 9.8 9.3 08/24/2006 04:10:00 10.9 1.1 13 7.2 11.1 1.2 13.3 7.2 10.1 1.2 12.2 6.5 97 5 97 165 9.8 0 10.1 9.3 08/24/2006 04:20:00 10.6 0.8 12.6 8.4 10.9 0.8 13 8.4 10.1 0.9 12.2 7.2 98 5 100 165 9.8 0.1 9.8 9.3 08/24/2006 04:30:00 10.8 1 13.7 7.6 11.1 1 13.7 7.6 10.2 1.2 13.7 6.8 106 6 107 165 9.7 0 10.1 9.3 08/24/2006 04:40:00 11.4 1.1 13.7 8 11.6 1.1 14.1 8.4 10.8 1.2 13 7.6 105 6 104 165 10 0.1 10.3 9.3 08/24/2006 04:50:00 11.7 1.4 14.9 8.4 12 1.3 14.9 8.8 11.1 1.5 14.5 7.6 100 6 98 165 10 0.2 10.3 9.3 08/24/2006 05:00:00 12.2 1.3 14.9 8.4 12.5 1.3 15.3 8.4 11.6 1.4 14.5 7.2 100 7 101 165 10.1 0.2 10.3 9.6 08/24/2006 05:10:00 12 1.2 15.3 8.8 12.2 1.2 15.6 8.8 11.2 1.3 14.5 7.6 102 6 112 165 10.1 0.2 10.3 9.6 08/24/2006 05:20:00 13 1 16.1 8.8 13.2 1.1 16.1 9.1 12.2 1.3 16.1 7.6 101 7 105 165 10.1 0.2 10.3 9.8 08/24/2006 05:30:00 12.1 1.4 15.6 8.4 12.2 1.4 16.1 8.4 11.6 1.5 16.1 7.2 109 6 108 165 10.1 0.1 10.3 9.6 08/24/2006 05:40:00 11.1 1.2 14.1 7.6 11.4 1.2 14.1 8 10.5 1.3 13.7 6.8 99 7 93 165 10.1 0.2 10.3 9.6 08/24/2006 05:50:00 12.3 1.3 15.3 8 12.6 1.4 15.6 7.6 11.5 1.3 14.9 8 92 6 98 165 10.1 0.1 10.3 9.6 08/24/2006 06:00:00 13 1.3 15.6 8.8 13.2 1.4 16.4 8.8 12.2 1.5 16.4 7.2 96 6 96 165 10.1 0.2 10.3 9.6 08/24/2006 06:10:00 12.4 1.1 14.5 8.8 12.7 1.2 14.9 8.4 11.7 1.3 14.5 8 92 6 92 165 10.1 0.2 10.3 9.6 08/24/2006 06:20:00 11.7 1.3 14.5 8.4 12.1 1.3 14.9 8.4 11.3 1.3 14.5 7.2 87 6 101 165 10.1 0.1 10.3 9.6 08/24/2006 06:30:00 11.4 1.4 14.1 7.2 11.7 1.3 14.5 7.6 10.9 1.3 13.7 6.8 85 7 87 165 10.1 0.1 10.3 9.6 08/24/2006 06:40:00 10.7 1.4 14.5 7.2 11 1.5 14.9 7.6 10.3 1.5 14.5 6.8 80 8 83 165 10.1 0.1 10.6 9.6 08/24/2006 06:50:00 10.1 1.6 14.9 6.1 10.4 1.6 15.3 6.5 9.9 1.5 14.5 6.1 72 9 83 165 10 0 10.3 9.6 08/24/2006 07:00:00 10.5 1.5 14.1 6.5 10.7 1.6 14.5 6.1 10.2 1.5 14.5 6.1 70 11 82 165 10.1 0.1 10.3 9.6 08/24/2006 07:10:00 10.3 1.7 15.3 6.1 10.5 1.7 14.9 6.1 9.9 1.6 14.9 6.5 66 10 34 165 10.1 0.1 10.3 9.6 08/24/2006 07:20:00 9.9 2 16.1 5.3 10.1 2 16.4 5.7 9.5 1.9 15.3 4.6 61 12 78 165 10.1 0 10.3 9.6 08/24/2006 07:30:00 9.6 1.9 14.5 5.7 9.7 2 14.9 5.3 9.3 2.1 14.9 5.3 56 11 58 165 10 0 10.3 9.3 08/24/2006 07:40:00 9.4 1.8 16.1 4.6 9.5 1.8 16.4 4.6 9 1.7 16.4 4.2 54 12 66 165 9.9 0 10.1 9.3 08/24/2006 07:50:00 8.7 1.7 14.5 4.9 8.8 1.8 15.3 4.9 8.2 1.5 14.1 4.6 53 13 63 165 9.9 0 9.8 9.6 08/24/2006 08:00:00 6.7 1.8 11.1 2.6 6.9 1.9 11.8 2.6 6.7 1.7 11.5 2.6 47 14 60 165 9.9 0 10.3 9.6 08/24/2006 08:10:00 6.7 1.5 11.5 3.4 6.9 1.6 11.8 3.4 6.6 1.3 10.7 3 48 16 84 165 10 0 10.1 9.6 08/24/2006 08:20:00 7 1.4 10.7 3.8 7.1 1.5 11.1 3.8 6.7 1.2 10.3 3.8 47 15 47 165 10 0 10.1 9.6 08/24/2006 08:30:00 6.2 1.2 9.9 3 6.2 1.2 9.9 3.4 6.1 1 8.8 3.8 42 16 77 165 10 0.2 10.3 9.6 08/24/2006 08:40:00 6.7 1.3 9.9 4.2 6.8 1.3 10.3 4.2 6.5 1.2 10.3 3.8 41 13 57 165 10 0.2 10.3 9.6 08/24/2006 08:50:00 5.9 0.9 8.4 3.8 5.8 0.9 8.4 2.3 5.9 0.9 8 4.2 29 12 62 165 10.1 0.2 10.3 9.6 08/24/2006 09:00:00 7.2 1 10.3 4.9 6.9 1.1 10.3 3.8 7.4 1.1 11.1 4.6 22 9 26 165 10.2 0.1 10.6 9.6 08/24/2006 09:10:00 9.3 1.2 12.2 4.9 8 1.3 11.8 4.9 9.3 1.3 13.3 6.1 14 8 10 165 10.1 0.2 10.6 9.6 08/24/2006 09:20:00 9.7 1.3 12.2 6.5 8.3 1.5 11.8 4.2 9.7 1.3 13.3 6.8 12 7 16 165 10.1 0.2 10.3 9.6 08/24/2006 09:30:00 9.2 1.1 11.8 6.5 6.5 1.1 9.5 3.4 9.4 1.2 12.2 6.8 7 6 12 165 10.1 0.2 10.6 9.6 08/24/2006 09:40:00 8.1 1.2 11.1 5.3 6.2 1.3 10.3 3.8 8.4 1.1 11.1 5.7 9 6 14 165 10.1 0.1 10.6 9.6 08/24/2006 09:50:00 7.7 1 10.3 5.3 6 1.3 9.5 3 7.9 0.9 10.3 5.3 10 8 16 165 10.5 0.2 10.9 9.8 08/24/2006 10:00:00 7.6 1 9.9 4.9 5.5 1.1 8.8 3 7.9 1 10.7 5.3 7 6 357 165 10.6 0.2 10.9 10.3 08/24/2006 10:10:00 7.9 1.1 10.3 5.3 5.8 1.4 10.3 3.4 8 1.2 11.5 4.9 8 7 13 165 10.7 0.1 10.9 10.3 08/24/2006 10:20:00 8.3 0.9 11.1 5.3 6.1 1.3 9.5 3.4 8.5 0.8 10.7 6.5 7 7 3 165 10.8 0 11.1 10.6 08/24/2006 10:30:00 8.1 0.8 10.7 6.1 5.8 1.1 9.1 3.4 8.3 0.8 11.1 6.1 7 6 5 165 10.9 0 11.1 10.6 08/24/2006 10:40:00 8.2 0.6 9.9 6.5 5.5 0.8 8.4 3.8 8.5 0.6 9.9 6.8 6 5 5 165 11.1 0.1 11.4 10.9 08/24/2006 10:50:00 7.7 0.7 9.5 5.7 5.6 1 8 3 7.9 0.8 9.9 5.7 9 5 4 165 11.2 0 11.4 10.9 08/24/2006 11:00:00 6.8 0.6 8.4 5.3 4.8 1 7.2 3 6.9 0.6 8.4 5.3 7 5 10 165 11.3 0 11.7 10.9 08/24/2006 11:10:00 6.9 0.7 8.4 5.3 4.3 0.7 6.5 3 7.2 0.6 8.8 5.7 4 5 8 165 11.5 0 11.7 11.4 08/24/2006 11:20:00 7.2 0.6 8.8 5.3 5.4 1 8 3 7.3 0.6 9.5 5.7 9 6 16 165 11.7 0 11.9 11.4 08/24/2006 11:30:00 7.7 0.7 9.1 6.1 5.9 1 9.1 3 7.9 0.9 9.5 5.7 10 5 16 165 11.7 0 11.7 11.4 08/24/2006 11:40:00 7 0.7 8.8 4.9 5.1 1 8.4 3 7.3 0.8 9.5 5.3 7 6 9 165 11.7 0 11.9 11.7 08/24/2006 11:50:00 6.1 0.6 7.2 4.9 3.8 0.8 6.5 2.3 6.4 0.5 7.6 4.9 4 6 357 165 11.8 0.1 11.9 11.1 08/24/2006 12:00:00 5.2 0.3 6.1 4.6 3.6 0.8 5.7 1.9 5.7 0.4 6.5 4.6 9 5 8 165 11.9 0.1 12.2 11.1 08/24/2006 12:10:00 4.4 0.3 5.7 3.8 2.8 0.7 4.9 1.5 4.8 0.3 5.7 4.2 3 7 19 165 11.7 0.3 12.2 11.1 08/24/2006 12:20:00 4.3 0.3 4.9 3.4 2.4 0.5 3.8 1.5 4.8 0.3 5.7 3.8 2 5 8 165 11.8 0.3 12.2 11.4 08/24/2006 12:30:00 3.9 0.3 4.6 3 2.1 0.6 3.8 1.1 4.3 0.3 4.9 3.4 359 4 5 165 12.1 0.2 12.5 11.4 08/24/2006 12:40:00 3.9 0.4 4.9 3 2.2 0.7 4.2 1.1 4.3 0.3 4.9 3.4 359 5 2 165 12.1 0.2 12.5 11.7 08/24/2006 12:50:00 4.1 0.3 5.3 3.4 3.5 0.7 4.6 1.1 4.4 0.3 5.3 3.8 351 5 358 165 12.3 0.1 12.7 11.9 08/24/2006 13:00:00 3.8 0.3 4.6 3 3.5 0.6 4.6 1.5 4.1 0.3 4.6 3.4 347 6 351 165 12.3 0.1 12.5 11.9 08/24/2006 13:10:00 3.6 0.5 4.6 2.3 3.4 0.6 4.9 1.5 3.9 0.4 4.9 3 340 8 353 165 12.3 0.1 12.5 11.9 08/24/2006 13:20:00 2.8 0.4 3.4 1.9 2.8 0.4 3.8 1.9 3.3 0.3 4.2 2.6 329 5 331 165 12.1 0.1 12.5 11.7 08/24/2006 13:30:00 2.7 0.2 3 1.9 2.7 0.2 3.4 1.9 3.1 0.2 3.4 2.3 337 5 325 165 12.1 0.1 12.5 11.7 08/24/2006 13:40:00 2.7 0.3 3.4 1.9 2.1 0.6 3.4 0.7 3 0.3 3.8 2.3 348 8 345 165 12.3 0.2 12.7 11.9 08/24/2006 13:50:00 2.2 0.4 3 1.1 1.9 0.5 3 0.4 2.6 0.3 3.4 1.9 342 8 351 165 12.4 0.1 13 11.9 08/24/2006 14:00:00 2.9 0.5 4.6 1.9 2.3 0.8 4.2 0.4 3.1 0.5 4.6 2.3 353 13 333 165 12.4 0.1 12.7 11.9 08/24/2006 14:10:00 2.7 0.4 3.8 1.5 2.4 0.6 3.8 0.7 3.1 0.4 3.8 1.5 341 15 21 165 12.1 0.2 12.7 11.7 08/24/2006 14:20:00 3 0.4 3.8 1.9 3.1 0.4 4.6 2.3 3.3 0.4 4.6 2.3 336 9 344 165 11.7 0.1 12.2 11.4 08/24/2006 14:30:00 2.8 0.5 4.6 1.9 2.9 0.5 4.6 1.9 3 0.5 4.9 1.5 334 12 336 165 11.7 0.2 11.9 11.4 08/24/2006 14:40:00 2.5 0.5 4.2 1.5 2.5 0.5 4.2 1.5 2.7 0.5 4.2 1.5 320 12 329 165 11.7 0.2 12.2 11.4 08/24/2006 14:50:00 2 0.3 3 1.1 2 0.4 3 0.4 2.3 0.3 3 1.5 322 15 305 165 11.7 0.2 11.9 11.4 08/24/2006 15:00:00 1.6 0.7 3.4 0.4 1.5 0.7 3 0.4 2.1 0.5 3 0.7 321 16 317 165 11.7 0.2 11.9 11.4 08/24/2006 15:10:00 1.1 0.4 2.3 0.4 0.9 0.4 1.9 0.4 1.5 0.4 2.3 0.4 322 21 350 165 11.7 0.2 11.9 11.4 08/24/2006 15:20:00 1.4 0.7 3 0.4 1.4 0.7 3 0.4 1.6 0.4 2.6 0.7 313 12 316 165 11.7 0.3 11.9 11.1 08/24/2006 15:30:00 1.8 0.4 2.6 0.7 1.8 0.5 2.6 0.4 1.8 0.4 3 0.7 302 7 304 165 11.6 0.3 11.9 11.1 08/24/2006 15:40:00 1.7 0.5 3.4 0.7 1.7 0.5 3 0.7 2.1 0.4 3 1.1 316 8 321 165 11.6 0.3 11.9 11.1 08/24/2006 15:50:00 3 0.8 4.9 1.5 2.8 0.7 4.9 1.1 3.1 0.6 4.6 1.9 336 10 352 165 11.7 0.2 11.9 11.4 08/24/2006 16:00:00 2.8 0.6 4.6 0.7 2.2 0.8 4.2 0.4 3 0.5 4.2 1.1 348 12 343 165 11.8 0.2 12.2 11.4 08/24/2006 16:10:00 3.4 0.6 4.9 2.3 2.5 0.7 4.6 1.1 3.5 0.6 5.3 1.9 358 12 360 165 11.7 0.3 11.9 11.1 08/24/2006 16:20:00 5.8 2 9.1 1.9 5.5 2.2 9.5 1.1 5.2 1.7 8.8 2.3 341 12 351 165 11.6 0.3 11.9 11.1 08/24/2006 16:30:00 7.1 1.3 10.7 3.4 6.8 1.5 11.1 1.9 6.3 1.2 9.9 3.4 341 12 342 165 11.5 0.3 11.9 11.1 08/24/2006 16:40:00 5.6 1.4 9.9 2.6 5.2 1.5 9.1 2.3 5.5 1.2 8.8 3 344 12 351 165 11.6 0.3 11.9 11.1 08/24/2006 16:50:00 6.4 1 9.9 3.4 6.2 1 8.8 3 6.2 1 10.3 3 334 15 354 165 11.6 0.3 11.9 11.1 08/24/2006 17:00:00 4.9 0.8 7.2 3 4.8 0.8 6.8 3 4.9 0.7 6.8 3 325 12 323 165 11.7 0.2 11.9 11.1 08/24/2006 17:10:00 5.8 1.3 10.3 3.4 5.7 1.2 8.8 3.4 5.5 1.3 9.9 3 321 15 358 165 11.7 0.3 11.9 11.1 08/24/2006 17:20:00 7.8 1.8 13 4.2 7.5 1.8 12.6 3.8 7.6 1.8 14.1 3.8 336 13 356 165 11.7 0.3 11.9 11.1 08/24/2006 17:30:00 9 1.8 13.7 4.2 8.8 1.8 13.3 4.2 8.7 1.8 13 4.6 340 10 338 165 11.7 0.2 11.9 11.1 08/24/2006 17:40:00 10.7 1.7 14.5 6.5 10.4 1.7 14.9 6.1 10.2 1.7 14.1 5.7 337 11 347 165 11.7 0.1 12.2 11.1 08/24/2006 17:50:00 12.4 2.2 18.3 8.4 12.4 2.2 19.1 7.6 12.2 2.3 17.6 7.2 337 9 351 165 11.7 0 11.9 11.1 08/24/2006 18:00:00 12.7 2 17.2 8 12.6 1.9 18.3 8 12.3 2 17.6 7.6 333 8 332 165 11.7 0 11.9 11.1 08/24/2006 18:10:00 14.4 2.2 20.2 9.1 14.4 2.4 19.9 7.6 13.8 2.4 20.2 8.4 342 8 332 165 11.6 0 11.9 11.1 08/24/2006 18:20:00 16.7 2.2 21.4 11.5 16.2 2.5 22.9 10.7 15.9 2.5 22.1 9.9 344 9 356 165 11.4 0 11.7 11.1 08/24/2006 18:30:00 17.3 1.9 22.6 12.6 16.6 2.4 22.1 10.7 16.5 1.9 21.4 11.5 347 8 343 165 11.3 0 11.7 10.9 08/24/2006 18:40:00 19.9 2.4 26.3 13 19.9 2.5 26 13 18.5 2.6 26 11.5 339 7 335 165 11.1 0 11.4 10.9 08/24/2006 18:50:00 21.6 2.7 27.9 14.9 21.2 3.1 27.5 12.6 20.9 2.7 28.7 13.3 340 9 325 165 11 0 11.7 10.9 08/24/2006 19:00:00 21.9 2.9 28.3 11.5 21.6 3.3 28.3 8 21.4 3.1 29.4 10.7 338 9 339 165 10.9 0 11.1 10.9 08/24/2006 19:10:00 21.8 2.8 30.6 13.7 21.6 2.8 30.2 13.3 21.2 2.9 28.7 13.3 334 9 334 165 10.9 0 11.1 10.6 08/24/2006 19:20:00 20.5 3.1 29.4 10.3 20.1 3.1 29.4 10.3 19.9 3.3 27.5 9.1 332 11 338 165 10.8 0 11.1 10.6 08/24/2006 19:30:00 19.5 2.5 26 12.2 19.4 2.5 25.2 12.2 19.4 2.8 26.3 9.5 332 10 349 165 10.8 0 11.1 10.6 08/24/2006 19:40:00 20.7 2.5 26 14.5 20.6 2.7 26.3 10.7 20.3 2.7 26 11.8 340 9 344 165 10.8 0 11.1 10.6 08/24/2006 19:50:00 18.2 2.3 23.7 11.5 18.3 2.5 24 11.5 17.6 2.7 22.9 9.5 340 9 355 165 10.7 0.1 10.9 10.6 08/24/2006 20:00:00 16.2 2 21.4 11.5 16 2.5 21.8 9.9 16.1 2.4 22.6 9.9 342 10 347 165 10.7 0.1 10.9 10.3 08/24/2006 20:10:00 16.3 2 22.1 11.1 16.2 2.2 21.4 10.7 16.1 2 21.8 10.7 339 11 351 165 10.7 0 11.1 10.6 08/24/2006 20:20:00 16.8 2.3 22.6 11.5 16.7 2.4 22.9 10.3 16.3 2.3 22.6 10.7 327 14 342 165 10.7 0.1 10.9 10.3 08/24/2006 20:30:00 19.4 2.2 25.6 13 19.3 2.2 24.8 13 18 2.4 23.7 12.2 317 12 307 165 10.7 0.1 10.9 10.3 08/24/2006 20:40:00 17.8 2.6 28.3 11.1 17.4 2.8 27.9 9.1 17.1 2.4 24.4 12.2 323 15 305 165 10.7 0.1 11.1 10.3 08/24/2006 20:50:00 16.2 2.1 22.6 10.3 15.4 2.2 23.3 10.3 16.3 2.4 22.9 8 342 14 1 165 10.7 0.1 10.9 10.3 08/24/2006 21:00:00 14.8 2.3 21.8 8.4 14.5 2.3 21.8 8.8 14 2.6 20.6 7.6 326 19 332 165 10.7 0.1 10.9 10.3 08/24/2006 21:10:00 13.9 2.6 22.6 8.4 13.6 2.3 19.9 8.4 13.5 2.7 23.3 8.8 329 15 358 165 10.7 0.1 10.9 10.1 08/24/2006 21:20:00 16.1 2.2 21.4 10.7 16.1 2.2 22.1 9.9 16.1 2.5 22.9 11.1 338 9 347 165 10.5 0 10.9 9.8 08/24/2006 21:30:00 14.8 2.8 21.4 9.1 14.7 2.7 20.6 9.5 14.7 2.9 22.1 8.4 331 12 356 165 10.4 0 10.9 10.1 08/24/2006 21:40:00 13.5 1.8 19.5 8.8 13 2.1 19.9 6.5 13.4 2 19.5 9.1 341 13 342 165 10.3 0 10.6 9.8 08/24/2006 21:50:00 15.1 2 20.2 9.5 13.9 2.2 19.5 8.8 14.6 2.2 19.5 7.6 346 13 357 165 10.3 0 10.6 9.8 08/24/2006 22:00:00 16.3 2.5 24 9.9 15.7 2.6 23.7 8.4 15.8 2.7 25.6 9.5 343 9 353 165 10.4 0 10.9 9.8 08/24/2006 22:10:00 18.1 2.4 24 11.8 17.7 2.4 23.3 11.8 17.6 2.7 25.2 11.5 337 11 355 165 10.3 0.2 10.9 9.6 08/24/2006 22:20:00 15.9 2.8 24.8 9.1 15.4 2.7 23.7 8.4 15.2 3.1 26 6.1 338 9 349 165 10.3 0.2 10.6 9.6 08/24/2006 22:30:00 16.6 2.1 23.3 10.7 16.1 2.1 23.3 10.7 16.4 2.2 24 10.7 343 10 338 165 10.3 0.2 10.6 9.8 08/24/2006 22:40:00 14.4 1.7 20.6 8.8 14.4 1.7 21 8.8 13.9 1.6 19.1 10.7 329 12 312 165 10.3 0.1 10.9 9.6 08/24/2006 22:50:00 14.2 1.7 20.6 10.3 13.8 1.7 19.9 8.8 13.9 1.7 20.2 9.9 337 12 343 165 10.3 0 10.6 9.8 08/24/2006 23:00:00 13.9 1.9 18.7 9.9 13.7 1.8 18.3 9.5 13.2 1.8 18.7 8.4 324 11 319 165 10.3 0.2 10.9 9.8 08/24/2006 23:10:00 14.9 2 21.8 8.8 14.7 2 21.4 8 13.8 2 18.3 7.2 321 16 296 165 10.4 0 10.9 9.8 08/24/2006 23:20:00 16.7 1.5 21.4 13 16.5 1.6 21 12.6 16.2 1.7 21 12.2 320 7 314 165 10.6 0.2 10.9 9.8 08/24/2006 23:30:00 16.4 1.4 21 11.8 16.2 1.4 21.4 11.8 15.5 1.6 20.2 11.5 319 7 306 165 10.6 0.2 11.1 10.1 08/24/2006 23:40:00 16.6 1.9 21 11.1 16.4 1.9 20.6 11.1 15 1.9 21 10.3 316 9 320 165 10.7 0.1 11.4 10.3 08/24/2006 23:50:00 18.5 1.5 22.6 14.9 18.2 1.5 21.8 14.9 17.9 1.7 22.6 13.7 317 4 321 165 10.5 0.1 10.9 10.1 08/25/2006 00:00:00 16.1 1.2 20.2 11.8 15.8 1.2 20.2 11.8 15.7 1.4 20.2 11.5 319 6 319 165 10.3 0.1 10.9 9.6 08/25/2006 00:10:00 16.9 1.3 20.2 12.6 16.6 1.3 19.9 12.6 16.6 1.6 20.6 11.8 326 6 322 165 10.6 0.1 10.9 10.3 08/25/2006 00:20:00 15.7 1.6 19.5 12.2 15.4 1.6 19.5 12.2 14.6 1.5 18.7 9.9 316 8 310 165 10.6 0 10.9 10.3 08/25/2006 00:30:00 16.6 1.3 19.5 13.3 16.4 1.3 19.5 13 15 1.3 19.5 11.1 313 5 308 165 10.5 0 11.1 10.1 08/25/2006 00:40:00 17.6 1.3 20.2 13.3 17.4 1.3 20.2 13.3 15.4 1.5 19.9 11.8 310 5 307 165 10.5 0 10.9 10.3 08/25/2006 00:50:00 17.4 1.4 20.6 12.2 17.2 1.4 20.2 12.2 15.9 1.6 20.2 11.8 313 6 310 165 10.7 0 10.9 10.6 08/25/2006 01:00:00 18.6 1.5 22.1 13.7 18.2 1.5 21.8 14.1 17.8 1.6 22.1 12.6 317 5 321 165 10.8 0 11.1 10.3 08/25/2006 01:10:00 19.7 1.5 22.9 15.3 19.4 1.5 22.6 15.6 19 1.7 22.6 14.9 317 5 312 165 10.7 0.1 11.1 10.3 08/25/2006 01:20:00 20.5 1.5 23.7 16.8 20.2 1.5 23.3 16.4 20 1.5 23.3 16.4 320 6 311 165 10.8 0.1 11.1 10.1 08/25/2006 01:30:00 22.5 1.8 27.9 18.3 22.1 1.7 27.1 17.9 22.3 2.1 27.5 18.3 320 6 322 165 10.8 0 11.1 10.3 08/25/2006 01:40:00 22.8 1.5 26.8 17.9 22.5 1.5 26.3 17.9 22.7 1.7 26.8 17.6 319 4 319 165 10.9 0.1 11.1 10.3 08/25/2006 01:50:00 18 1.4 21.4 14.9 17.7 1.3 21 14.9 17.9 1.4 21.8 13.7 320 4 322 165 10.7 0.2 11.1 10.3 08/25/2006 02:00:00 16.3 1 18.7 13.3 16.1 1 18.7 13 16.1 1.1 19.1 13 322 5 315 165 10.5 0 11.1 9.8 08/25/2006 02:10:00 14.9 0.9 16.8 12.6 14.7 0.9 16.4 12.2 14.8 0.9 16.8 11.8 320 6 318 165 10.4 0 10.6 10.3 08/25/2006 02:20:00 15.1 1.3 19.5 12.6 15 1.3 19.1 12.2 14.2 1.6 19.5 10.3 313 5 316 165 10.5 0.1 10.9 10.3 08/25/2006 02:30:00 14.1 1.1 17.2 10.7 13.9 1.1 17.2 10.7 13.6 1.3 16.4 10.7 316 6 322 165 10.7 0 11.1 10.6 08/25/2006 02:40:00 14.3 1.3 17.2 11.1 14.1 1.3 16.8 10.7 13.7 1.3 16.8 9.9 315 6 315 165 10.9 0 11.1 10.3 08/25/2006 02:50:00 14.4 1.3 18.7 11.5 14.2 1.3 18.3 11.1 14 1.3 17.2 9.9 317 4 310 165 10.8 0.1 11.1 10.3 08/25/2006 03:00:00 15.7 1.1 18.7 13.3 15.5 1.1 18.7 12.6 15 1.2 18.3 11.1 314 5 312 165 10.7 0.1 11.1 10.1 08/25/2006 03:10:00 16.8 0.9 19.1 14.5 16.7 0.9 19.1 14.5 15.6 1.3 18.7 11.1 313 5 306 165 10.8 0.1 11.1 10.1 08/25/2006 03:20:00 15.6 1 17.9 13 15.4 1.1 17.9 12.6 15.1 1.2 17.9 11.5 316 5 314 165 10.7 0.1 11.1 10.3 08/25/2006 03:30:00 16.4 1 19.1 13.3 16.2 1 19.1 13.3 16.3 1 19.1 13.7 319 5 322 165 10.7 0.1 10.9 10.1 08/25/2006 03:40:00 18.5 1.1 21 14.9 18.3 1.2 21 15.3 17.8 1.3 21 14.1 315 5 315 165 10.8 0 11.1 10.3 08/25/2006 03:50:00 21.1 1.2 24 17.6 20.9 1.3 24 17.6 19.8 1.7 23.3 14.1 313 4 316 165 10.9 0 11.1 10.3 08/25/2006 04:00:00 19.5 1.5 23.3 14.5 19.3 1.5 22.9 13.7 17.8 1.7 21.4 12.6 312 5 311 165 11.3 0.1 11.7 10.9 08/25/2006 04:10:00 17.2 1.3 21 13.7 17 1.3 21 13.3 16.3 1.4 21.8 12.6 313 5 315 165 11.4 0.1 11.7 10.9 08/25/2006 04:20:00 15.3 2 19.5 10.3 15.2 2 19.1 10.3 13.1 2.7 18.7 7.2 308 6 302 165 11.4 0.2 11.7 10.9 08/25/2006 04:30:00 12.7 1.3 16.1 9.1 12.7 1.4 16.4 9.5 10 1.4 13.7 7.2 300 7 300 165 11.1 0.2 11.7 10.3 08/25/2006 04:40:00 12.1 1.1 15.3 9.9 12.1 1.1 15.3 9.5 10 1.5 13.7 6.5 301 8 305 165 11.1 0.1 11.4 10.6 08/25/2006 04:50:00 13.2 1.5 17.2 9.9 13.2 1.6 17.6 9.9 10.2 1.7 16.8 6.8 301 6 292 165 11.1 0.1 11.4 10.6 08/25/2006 05:00:00 13.7 1 16.4 11.1 13.7 1 16.8 11.1 10.8 1.8 15.6 7.2 296 6 286 165 11.3 0.2 11.9 10.9 08/25/2006 05:10:00 14.3 0.9 16.4 11.8 14.4 0.9 16.4 11.8 11.6 1.8 16.4 7.6 293 5 287 165 11.5 0.1 11.7 10.9 08/25/2006 05:20:00 14.1 1 16.4 11.1 14.1 1.1 16.4 11.1 10.7 1.5 14.9 7.2 296 5 298 165 11.5 0.2 11.7 10.9 08/25/2006 05:30:00 14.2 1.1 17.6 11.5 14.3 1.1 17.6 11.1 11.1 1.5 16.4 7.2 295 5 304 165 11.3 0 11.7 10.9 08/25/2006 05:40:00 14.4 1.1 17.6 11.5 14.5 1.1 17.2 11.5 10.9 1.6 16.1 7.6 298 6 300 165 11.2 0.2 11.4 10.6 08/25/2006 05:50:00 13.7 1.2 16.8 10.7 13.7 1.2 16.8 10.7 11.4 2 16.4 7.2 304 7 310 165 11.4 0.1 11.9 10.9 08/25/2006 06:00:00 13.5 1 15.6 9.1 13.5 1.1 15.6 9.5 11.6 1.6 14.5 7.6 308 5 308 165 11.3 0 11.7 10.9 08/25/2006 06:10:00 12.5 1.3 16.8 9.1 12.5 1.4 16.8 9.1 10.5 1.7 16.1 7.6 304 8 315 165 11.5 0.1 11.9 10.9 08/25/2006 06:20:00 10.5 1.5 14.5 6.5 10.7 1.5 14.5 6.5 9.4 1.8 14.5 5.7 290 10 296 165 11.9 0.1 12.2 11.4 08/25/2006 06:30:00 7 1.7 10.7 3.4 7.4 1.5 11.1 4.2 7.2 1.6 11.5 3.8 273 15 284 165 11.9 0.1 12.2 11.4 08/25/2006 06:40:00 7.5 1.8 11.8 2.6 8.1 1.7 11.8 3 7.7 1.6 11.5 3.8 274 14 289 165 11.7 0 11.9 11.4 08/25/2006 06:50:00 7.1 1.3 9.9 3.4 8 1.1 10.3 4.9 7.6 1 10.3 4.9 273 6 285 165 11.7 0 11.9 11.4 08/25/2006 07:00:00 5.1 1.2 8.8 2.6 5.8 1.1 9.1 3.8 5.7 1 8.8 3.4 268 9 277 165 11.8 0 11.9 11.4 08/25/2006 07:10:00 5.2 1.2 8 2.3 5.8 1.1 9.1 3.4 5.6 1.1 8.8 3.4 266 13 277 165 11.9 0 12.2 11.7 08/25/2006 07:20:00 5.8 1.6 9.5 1.9 6.4 1.5 9.9 2.3 6.2 1.5 9.9 3 267 13 279 165 11.9 0.1 12.2 11.7 08/25/2006 07:30:00 5.9 1.2 8.8 3 6.4 1.1 8.8 3.8 6.2 1.1 8.4 3.8 258 15 247 165 11.7 0 12.2 11.7 08/25/2006 07:40:00 7.4 1 9.5 5.3 9 0.8 11.1 6.1 8.8 0.8 10.7 6.1 269 6 265 165 11.6 0 11.9 11.4 08/25/2006 07:50:00 8.2 1.4 11.1 4.6 10 0.6 11.8 8 9.8 0.7 12.2 7.2 271 6 276 165 11.5 0 11.9 11.4 08/25/2006 08:00:00 9.8 1.5 13.3 5.3 10.7 1.1 13.3 7.2 10.1 1.3 13 6.1 277 8 278 165 11.6 0 11.9 11.4 08/25/2006 08:10:00 8.6 1.5 12.6 6.1 10 1.1 13.3 6.8 9.4 1.1 12.6 6.1 273 7 276 165 11.5 0 11.7 11.1 08/25/2006 08:20:00 10.2 1.3 13.7 5.7 10.8 1.1 13.3 7.6 10.3 1.3 13.7 6.8 277 8 283 165 11.5 0 11.7 11.4 08/25/2006 08:30:00 10.4 1.3 13.7 6.5 11 1.2 14.1 7.6 10.5 1.3 14.1 7.2 278 6 279 165 11.7 0 11.9 11.4 08/25/2006 08:40:00 11.4 1 14.1 7.6 11.6 1 14.1 7.6 11 1.3 13.7 7.6 284 4 285 165 11.6 0 11.9 11.4 08/25/2006 08:50:00 9.8 1.1 12.2 5.7 10.4 0.9 12.6 7.6 9.7 1.1 12.6 6.5 278 6 279 165 11.7 0.1 11.9 11.4 08/25/2006 09:00:00 8.1 1.1 10.3 4.2 8.9 0.7 10.7 6.5 8.4 1 11.1 4.9 277 8 276 165 11.8 0 11.9 11.7 08/25/2006 09:10:00 6.7 1.2 9.5 4.2 6.8 1.2 9.9 4.2 5.6 1.4 9.1 3 295 6 289 165 11.7 0 12.2 11.7 08/25/2006 09:20:00 5 0.7 7.2 3.4 5.2 0.7 7.2 3.4 4.5 0.7 7.2 3 292 9 305 165 11.7 0 11.9 11.4 08/25/2006 09:30:00 5 0.5 6.1 3.8 5.2 0.5 6.5 4.2 4.6 0.6 6.5 3 289 6 291 165 11.8 0.1 11.9 11.4 08/25/2006 09:40:00 2.2 1.2 4.6 0.4 2.6 1.1 5.3 0.4 2.6 1 4.9 0.4 278 8 287 165 11.9 0.2 12.2 11.4 08/25/2006 09:50:00 0.8 0.5 2.3 0.4 1.1 0.6 2.6 0.4 1.2 0.5 2.6 0.4 288 17 289 165 12.3 0.2 12.7 11.7 08/25/2006 10:00:00 0.8 0.4 1.9 0.4 1.1 0.5 2.6 0.4 1.3 0.5 2.6 0.4 279 18 297 165 12.8 0.2 13.3 12.2 08/25/2006 10:10:00 1 0.8 3.4 0.4 1.3 0.8 3.8 0.4 1.6 0.8 3.8 0.4 232 38 178 165 13.3 0.1 13.5 12.7 08/25/2006 10:20:00 1.9 0.8 3.8 0.4 2 0.8 4.2 0.4 2.6 0.5 4.9 1.1 188 12 174 165 13.5 0.2 13.8 12.7 08/25/2006 10:30:00 0.8 0.4 2.3 0.4 0.8 0.5 2.3 0.4 1.5 0.5 3 0.4 175 8 173 165 13.2 0 13.3 12.7 08/25/2006 10:40:00 1.9 0.9 3.8 0.4 2 1 3.8 0.4 2.4 0.8 4.2 0.7 163 10 155 165 13.7 0.3 14.4 13 08/25/2006 10:50:00 2.3 0.5 3.4 0.7 2.5 0.5 3.8 1.1 2.8 0.5 3.8 1.1 127 11 162 165 13.7 0.1 14.4 13.3 08/25/2006 11:00:00 1.4 0.7 3.4 0.4 1.6 0.7 3.4 0.4 2.1 0.6 4.2 1.1 137 20 154 165 14.2 0 14.6 13.5 08/25/2006 11:10:00 1.1 0.6 2.6 0.4 1.2 0.8 3 0.4 1.8 0.7 3.4 0.4 160 12 172 165 14.3 0 14.6 13.5 08/25/2006 11:20:00 0.9 0.6 3 0.4 1 0.7 3.4 0.4 1.5 0.7 3.8 0.4 158 17 144 165 14.1 0.1 14.9 13.8 08/25/2006 11:30:00 0.9 0.6 2.3 0.4 1 0.7 3 0.4 1.4 0.7 3 0.4 210 47 168 165 14.1 0.2 14.9 13.8 08/25/2006 11:40:00 2 1.5 6.5 0.4 2 1.5 6.5 0.4 1.9 1.5 6.1 0.4 155 90 91 165 15.8 0.3 16.6 14.9 08/25/2006 11:50:00 2.3 1 4.2 0.4 2.3 1 4.6 0.4 3 0.7 4.6 0.7 130 18 114 165 15.4 0.3 16.3 15.2 08/25/2006 12:00:00 2.9 0.9 4.9 0.4 3 1 4.9 0.4 3.5 0.7 4.9 1.1 147 17 162 165 15.5 0.2 16.3 15.2 08/25/2006 12:10:00 2.8 0.7 4.6 0.7 2.8 0.8 4.6 0.7 3.2 0.7 4.9 1.5 143 15 139 165 15.3 0.2 16 15.2 08/25/2006 12:20:00 3.3 0.8 5.7 1.5 3.3 0.8 5.7 1.1 3.7 0.7 5.3 1.9 147 8 164 165 15.2 0.4 16 14.6 08/25/2006 12:30:00 3.4 0.6 4.9 1.5 3.5 0.6 4.9 1.9 3.8 0.6 5.7 2.3 137 9 142 165 14.7 0.1 15.5 14.4 08/25/2006 12:40:00 1.7 0.9 3.8 0.4 1.8 1 3.8 0.4 2.2 0.9 4.2 0.4 148 21 166 165 15.2 0.1 15.7 14.9 08/25/2006 12:50:00 2.9 1.2 5.7 0.4 2.9 1.2 5.7 0.4 3.2 1.3 6.1 0.4 143 22 169 165 14.8 0.3 15.5 14.4 08/25/2006 13:00:00 3.1 0.7 4.9 1.5 3.1 0.7 5.3 1.1 3.5 0.6 5.3 1.9 165 11 182 165 15 0.2 15.5 14.6 08/25/2006 13:10:00 3.9 0.9 5.7 1.9 3.9 0.9 6.1 1.5 4.2 0.9 6.1 1.5 156 7 164 165 15 0 15.5 14.6 08/25/2006 13:20:00 4 0.8 6.5 2.6 4 0.8 6.1 2.3 4.4 0.8 6.8 2.6 150 8 152 165 14.8 0.3 15.5 14.4 08/25/2006 13:30:00 4.8 0.6 6.5 3.4 4.7 0.5 6.5 3.4 5 0.6 6.8 3 138 6 136 165 14.2 0.5 15.5 13.5 08/25/2006 13:40:00 4 0.7 6.1 2.6 4 0.7 6.1 2.6 4.3 0.7 6.1 3 143 9 143 165 14.1 0.2 14.6 13.5 08/25/2006 13:50:00 2.9 0.5 4.9 1.9 2.9 0.5 4.9 1.9 3.3 0.5 4.9 2.3 130 9 150 165 13.6 0.1 14.1 13.3 08/25/2006 14:00:00 3 0.8 6.5 1.1 3 0.8 6.5 1.1 3.4 0.6 5.3 1.9 135 14 138 165 14.1 0.1 14.4 13.8 08/25/2006 14:10:00 3.4 0.6 5.3 1.9 3.4 0.6 5.7 1.5 3.7 0.5 6.1 2.3 121 9 129 165 14.2 0 14.6 14.1 08/25/2006 14:20:00 3.8 0.6 5.3 2.3 3.8 0.7 5.7 2.3 4.2 0.5 5.7 2.6 119 8 105 165 14.9 0.3 15.5 14.4 08/25/2006 14:30:00 4.7 0.6 6.1 3 4.8 0.6 6.5 3.4 5 0.6 6.8 3.4 117 7 121 165 14.8 0 15.5 14.6 08/25/2006 14:40:00 4.6 0.6 6.1 3 4.6 0.6 6.5 3 5 0.6 6.5 2.6 120 7 120 165 14.5 0 15.2 14.4 08/25/2006 14:50:00 4.6 0.7 6.1 3 4.7 0.8 6.5 3 4.9 0.8 6.8 2.6 119 9 119 165 14.3 0.1 15.2 14.1 08/25/2006 15:00:00 4.3 0.6 5.7 2.6 4.3 0.7 6.1 3 4.5 0.6 6.1 3 119 11 111 165 14.3 0.2 15.2 14.1 08/25/2006 15:10:00 4.4 0.8 6.5 2.3 4.5 0.8 6.8 2.3 4.7 0.8 6.8 2.6 117 10 118 165 14.5 0 15.2 14.4 08/25/2006 15:20:00 4.3 0.8 6.1 2.3 4.4 0.8 6.1 2.3 4.6 0.7 6.5 3 112 10 117 165 14.6 0.1 15.2 14.4 08/25/2006 15:30:00 4.5 0.7 6.8 2.6 4.6 0.7 6.8 2.6 4.7 0.8 6.8 2.6 107 11 112 165 14.6 0.1 15.2 14.4 08/25/2006 15:40:00 4.3 0.5 5.7 3 4.4 0.6 5.7 2.6 4.4 0.6 6.1 3 107 9 88 165 15.1 0.2 15.5 14.6 08/25/2006 15:50:00 4.1 0.6 5.7 2.6 4.1 0.6 5.7 2.3 4.3 0.6 5.7 3 113 9 112 165 14.8 0.2 15.7 14.6 08/25/2006 16:00:00 4.8 0.5 6.1 3.4 4.8 0.5 6.1 3 5 0.5 6.5 3.4 117 8 115 165 14.2 0.2 14.9 14.1 08/25/2006 16:10:00 4.5 0.7 6.1 2.6 4.5 0.7 6.5 2.6 4.8 0.7 6.5 3 114 8 111 165 13.6 0.3 14.6 13 08/25/2006 16:20:00 4.3 0.7 6.1 2.6 4.3 0.7 7.2 2.3 4.4 0.8 6.8 2.3 112 9 116 165 12.7 0.1 13.3 12.5 08/25/2006 16:30:00 3.6 0.7 4.9 1.9 3.7 0.6 5.3 2.3 3.9 0.6 5.7 2.3 106 11 96 165 12.4 0 12.7 12.2 08/25/2006 16:40:00 3 0.6 4.6 1.5 3.1 0.6 4.9 1.9 3.4 0.7 4.9 1.9 104 16 119 165 12.7 0.2 13 12.5 08/25/2006 16:50:00 3.5 0.8 5.3 1.1 3.6 0.8 5.3 1.1 3.8 0.7 5.3 2.3 108 9 103 165 12.7 0.2 13.3 12.5 08/25/2006 17:00:00 2.4 0.5 3.8 1.1 2.5 0.5 3.8 1.5 2.9 0.4 4.2 1.9 112 9 129 165 12.2 0 12.5 11.9 08/25/2006 17:10:00 1.2 0.6 2.6 0.4 1.2 0.6 3 0.4 1.5 0.6 3 0.4 92 13 105 165 12 0 12.2 11.7 08/25/2006 17:20:00 1.6 0.6 2.6 0.4 1.3 0.6 2.6 0.4 1.9 0.5 3 0.4 34 29 7 165 11.9 0 12.2 11.7 08/25/2006 17:30:00 2 0.4 3 1.1 1.7 0.4 2.6 0.7 2.4 0.3 3 1.5 28 9 43 165 11.6 0 11.9 11.1 08/25/2006 17:40:00 2.2 0.4 3.4 1.1 2 0.5 3.4 0.7 2.4 0.4 3.4 1.5 30 7 37 165 11.5 0 11.7 11.1 08/25/2006 17:50:00 1.5 0.5 3 0.4 1.1 0.6 3 0.4 1.7 0.5 3 0.7 27 13 44 165 11.6 0 11.7 11.4 08/25/2006 18:00:00 0.8 0.5 1.9 0.4 0.5 0.3 1.5 0.4 1 0.6 2.6 0.4 23 12 18 165 11.5 0 11.7 11.4 08/25/2006 18:10:00 1 0.3 1.5 0.4 0.5 0.2 1.5 0.4 1.2 0.3 1.9 0.7 27 9 48 165 11.5 0 11.7 11.1 08/25/2006 18:20:00 1.4 0.2 1.9 0.7 0.5 0.2 1.1 0.4 1.8 0.2 2.3 1.5 10 11 12 165 11.3 0 11.7 11.1 08/25/2006 18:30:00 1.1 0.5 2.3 0.4 0.6 0.4 1.9 0.4 1.5 0.5 2.6 0.4 15 7 5 165 11.2 0 11.4 11.1 08/25/2006 18:40:00 0.4 0.2 1.1 0.4 0.4 0 0.4 0.4 0.6 0.4 1.5 0.4 69 61 17 165 11.3 0 11.4 11.1 08/25/2006 18:50:00 0.6 0.3 1.1 0.4 0.4 0 0.4 0.4 1.1 0.4 1.9 0.4 176 7 180 165 11.1 0 11.1 10.9 08/25/2006 19:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0.1 1.1 0.4 178 0 165 165 10.8 0 11.1 10.9 08/25/2006 19:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 178 0 165 165 10.7 0 10.9 10.6 08/25/2006 19:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.5 0.3 1.1 0.4 91 41 165 165 10.6 0 10.9 10.6 08/25/2006 19:30:00 1 0.3 1.5 0.4 0.4 0.2 1.1 0.4 1.4 0.3 1.9 0.7 12 2 11 165 10.2 0.1 10.6 9.8 08/25/2006 19:40:00 2.2 0.5 3 1.1 0.7 0.3 1.5 0.4 2.5 0.4 3 1.5 6 4 3 165 10 0.1 10.6 9.6 08/25/2006 19:50:00 1 0.4 2.3 0.4 0.4 0.1 1.1 0.4 1.2 0.3 2.3 0.7 3 9 357 165 9.8 0 10.3 9.6 08/25/2006 20:00:00 0.4 0 0.7 0.4 0.4 0 0.4 0.4 0.5 0.2 1.1 0.4 18 0 18 165 10 0 10.3 9.6 08/25/2006 20:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 41 35 165 165 10 0 10.3 9.6 08/25/2006 20:20:00 0.9 0.5 2.3 0.4 0.7 0.5 2.3 0.4 1.1 0.7 2.6 0.4 121 26 164 165 9.9 0.2 10.3 9.3 08/25/2006 20:30:00 2.2 0.2 2.6 1.5 2 0.2 2.6 1.1 2.5 0.2 3 1.9 164 5 165 165 9.4 0.2 9.8 9 08/25/2006 20:40:00 2.4 0.2 3 1.9 2.3 0.2 2.6 1.9 2.7 0.2 3 1.9 174 8 177 165 9.3 0.2 9.8 9 08/25/2006 20:50:00 2.6 0.3 3 1.9 2.6 0.3 3 1.5 3 0.3 3.4 1.9 185 5 178 165 9.4 0.2 9.8 9 08/25/2006 21:00:00 2.4 0.3 3 1.5 2.4 0.3 3 1.5 2.8 0.3 3.4 1.9 185 2 187 165 9.4 0 9.6 8.8 08/25/2006 21:10:00 0.7 0.4 1.9 0.4 0.6 0.4 1.9 0.4 1.5 0.4 2.6 0.7 188 4 183 165 9.2 0 9.6 9 08/25/2006 21:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0.2 1.1 0.4 149 43 165 165 9.1 0 9.3 9 08/25/2006 21:30:00 0.8 0.4 1.5 0.4 0.4 0.2 1.1 0.4 1.4 0.3 2.3 0.7 330 5 325 165 9.1 0 9.3 9 08/25/2006 21:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0.1 1.1 0.4 330 0 165 165 9.2 0 9.6 9 08/25/2006 21:50:00 0.5 0.3 1.1 0.4 0.4 0 0.4 0.4 0.9 0.4 1.5 0.4 46 86 143 165 9.5 0.1 9.6 9 08/25/2006 22:00:00 0.7 0.3 1.1 0.4 0.4 0 0.4 0.4 1.2 0.2 1.9 0.7 135 0 135 165 9.5 0.1 9.6 9 08/25/2006 22:10:00 0.7 0.3 1.5 0.4 0.4 0 0.4 0.4 1.2 0.3 1.9 0.7 125 10 135 165 9.3 0 9.6 9 08/25/2006 22:20:00 0.6 0.3 1.1 0.4 0.4 0 0.4 0.4 1.4 0.3 1.9 0.7 107 0 107 165 9.3 0 9.6 9 08/25/2006 22:30:00 1.4 0.4 2.3 0.7 1.1 0.6 2.3 0.4 1.8 0.3 2.3 1.1 108 3 113 165 9.3 0 9.6 9 08/25/2006 22:40:00 2 0.2 2.6 1.5 2.1 0.3 2.6 1.1 2 0.2 2.6 1.5 113 0 113 165 9.2 0.1 9.6 8.8 08/25/2006 22:50:00 1.8 0.3 2.6 1.1 1.9 0.4 2.6 1.1 2.1 0.3 2.6 1.5 112 4 111 165 9.1 0 9.3 8.8 08/25/2006 23:00:00 0.9 0.4 1.5 0.4 0.7 0.4 1.5 0.4 1.2 0.4 1.9 0.4 82 21 104 165 9.1 0.1 9.6 8.8 08/25/2006 23:10:00 0.9 0.4 1.9 0.4 0.6 0.3 1.5 0.4 1.2 0.4 1.9 0.4 75 10 58 165 9 0.2 9.3 8.5 08/25/2006 23:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.5 0.2 1.1 0.4 57 20 165 165 8.9 0.2 9.3 8.5 08/25/2006 23:30:00 1.2 0.8 3 0.4 0.9 0.7 2.6 0.4 1.6 0.7 3 0.4 24 8 34 165 8.9 0 9 8.5 08/25/2006 23:40:00 2.4 0.4 3 1.1 2.2 0.4 3 0.7 2.5 0.3 3.4 1.5 30 5 39 165 9 0.1 9 8.5 08/25/2006 23:50:00 2.4 0.3 3 1.5 2.3 0.4 3 1.1 2.7 0.3 3.4 1.9 30 8 37 165 9 0.1 9.3 8.8 08/26/2006 00:00:00 2.6 0.3 3.4 1.9 2.6 0.3 3.4 1.9 2.9 0.4 4.2 1.9 40 3 37 165 9 0.1 9.3 8.8 08/26/2006 00:10:00 1.9 0.4 2.6 0.7 1.9 0.5 3 0.7 2.3 0.4 3 1.5 47 6 40 165 9 0.1 9.6 8.8 08/26/2006 00:20:00 1.8 0.4 2.6 0.4 1.7 0.5 2.6 0.4 2.1 0.4 3 1.1 46 8 44 165 9 0.1 9.3 8.8 08/26/2006 00:30:00 2.3 0.4 3.4 1.1 2.3 0.5 3 1.1 2.5 0.4 3.4 1.1 49 6 49 165 9 0.1 9 8.5 08/26/2006 00:40:00 2.1 0.3 2.6 1.1 2 0.4 2.6 1.1 2.3 0.3 3 1.5 40 5 43 165 9 0.1 9.6 8.5 08/26/2006 00:50:00 2.2 0.4 3 1.1 2.2 0.4 3.4 1.1 2.5 0.3 3.4 1.5 43 9 48 165 9 0.1 9.3 8.5 08/26/2006 01:00:00 1.8 0.3 2.3 1.1 1.6 0.3 2.6 0.7 2.2 0.3 2.6 1.1 38 10 26 165 9 0.1 9.6 8.5 08/26/2006 01:10:00 1 0.4 1.9 0.4 1.1 0.5 2.3 0.4 1.8 0.3 2.6 1.1 90 12 73 165 9.1 0 9.6 8.5 08/26/2006 01:20:00 1.1 0.3 1.9 0.4 1.3 0.4 2.3 0.4 1.8 0.3 2.3 1.1 105 9 111 165 9.3 0 9.3 8.5 08/26/2006 01:30:00 1.1 0.3 1.5 0.4 1.3 0.3 1.9 0.4 1.8 0.3 2.3 0.7 107 5 118 165 9.2 0.1 9.6 8.5 08/26/2006 01:40:00 0.7 0.4 1.5 0.4 0.7 0.4 1.9 0.4 1.5 0.3 2.3 0.7 100 4 107 165 9.2 0.1 9.6 8.8 08/26/2006 01:50:00 1.6 0.4 2.3 0.7 1.8 0.5 2.6 0.4 2.1 0.3 3 1.5 109 6 109 165 9.2 0.2 9.6 8.5 08/26/2006 02:00:00 1.6 0.4 2.6 0.4 1.9 0.3 2.6 1.1 2 0.4 2.6 1.1 120 9 129 165 9 0.2 9.3 8.5 08/26/2006 02:10:00 2 0.3 3 1.1 2.3 0.3 3 1.5 2.4 0.3 3.4 1.5 119 5 127 165 9 0.2 9.3 8.5 08/26/2006 02:20:00 2.2 0.3 3 1.5 2.4 0.3 3 1.5 2.6 0.3 3 1.9 120 4 118 165 9.1 0.1 9.3 8.5 08/26/2006 02:30:00 1.7 0.4 2.6 0.7 2 0.3 2.6 1.5 2.3 0.3 3 1.5 112 6 121 165 9.2 0 9.3 8.8 08/26/2006 02:40:00 2.1 0.4 3 1.1 2.3 0.4 3.4 1.1 2.5 0.4 3.4 1.5 82 8 81 165 9.3 0 9.6 8.8 08/26/2006 02:50:00 2.3 0.5 3.8 1.1 2.5 0.5 3.8 1.1 2.5 0.4 3.8 1.1 78 9 82 165 9.3 0 9.6 9 08/26/2006 03:00:00 1.9 0.5 3.4 0.4 1.9 0.6 3.4 0.4 2.1 0.5 3.4 1.1 54 11 51 165 9.3 0 9.6 8.8 08/26/2006 03:10:00 2.3 0.4 3 1.1 2.3 0.5 3.4 0.7 2.5 0.4 3.4 1.5 48 7 62 165 9.2 0 9.3 8.8 08/26/2006 03:20:00 2.6 0.3 3.4 1.9 2.7 0.3 3.4 1.9 2.7 0.3 3.4 1.9 48 6 44 165 9.2 0 9.3 8.8 08/26/2006 03:30:00 2.7 0.4 3.4 1.9 2.7 0.4 3.4 1.5 2.8 0.4 3.4 1.9 43 7 50 165 9.3 0 9.3 9 08/26/2006 03:40:00 2.2 0.3 2.6 1.5 2.2 0.3 3 1.1 2.4 0.3 3 1.5 44 7 32 165 9.3 0 9.6 8.8 08/26/2006 03:50:00 1.8 0.3 2.6 1.1 1.7 0.4 2.6 0.7 2 0.4 3 1.1 51 6 54 165 9.4 0 9.6 9.3 08/26/2006 04:00:00 2.6 0.3 3.4 1.9 2.7 0.3 3.4 1.9 2.7 0.4 3.4 1.5 56 4 63 165 9.4 0 9.3 9.3 08/26/2006 04:10:00 1.9 0.4 2.6 1.1 1.9 0.4 3 0.7 2.1 0.3 3 1.5 58 12 54 165 9.4 0 9.3 9.3 08/26/2006 04:20:00 2.1 0.7 3.8 0.4 2.3 0.7 4.2 0.4 2.3 0.5 3.4 0.7 94 14 102 165 9.4 0 9.6 8.8 08/26/2006 04:30:00 1.5 0.7 3 0.4 1.9 0.7 3.4 0.4 2 0.6 3.4 0.7 99 8 102 165 9.6 0 9.6 9.6 08/26/2006 04:40:00 2.1 0.7 3.8 0.4 2.4 0.6 4.2 1.1 2.4 0.6 3.8 0.7 108 7 110 165 9.6 0.1 10.1 9 08/26/2006 04:50:00 2.5 0.3 3.4 1.5 2.8 0.3 3.4 1.5 2.9 0.3 3.8 2.3 116 7 124 165 9.6 0 9.8 9.3 08/26/2006 05:00:00 2.3 0.3 3 1.9 2.6 0.3 3 1.9 2.8 0.3 3.4 2.3 105 5 102 165 9.6 0 9.8 9.3 08/26/2006 05:10:00 2.1 0.5 3 0.7 2.4 0.5 3 0.7 2.6 0.4 3.4 1.5 123 10 118 165 9.6 0.1 9.6 9 08/26/2006 05:20:00 2.5 0.8 3.8 0.4 2.9 0.7 3.8 0.7 3 0.7 4.2 1.5 119 8 106 165 9.6 0.1 9.6 9 08/26/2006 05:30:00 2.5 0.3 3.4 1.9 2.9 0.2 3.4 2.3 3 0.2 3.4 2.3 117 3 115 165 9.6 0 9.6 9 08/26/2006 05:40:00 1.9 0.4 2.6 0.7 2.2 0.4 3 1.1 2.4 0.4 3 1.1 106 9 95 165 9.6 0 9.6 9.3 08/26/2006 05:50:00 2 0.5 3.8 0.7 2.4 0.5 3.8 1.5 2.4 0.5 3.8 1.1 102 12 90 165 9.6 0 9.6 9.3 08/26/2006 06:00:00 3 0.6 4.2 1.5 3.2 0.6 4.2 1.5 3.1 0.6 4.2 1.5 90 9 91 165 9.6 0 9.6 9 08/26/2006 06:10:00 3.2 0.4 4.2 2.3 3.5 0.4 4.6 2.3 3.4 0.4 4.2 2.3 92 4 99 165 9.6 0 9.6 9 08/26/2006 06:20:00 2.6 0.4 3.8 1.9 2.9 0.4 3.8 1.9 2.9 0.4 3.8 1.9 85 6 90 165 9.6 0 9.6 9.3 08/26/2006 06:30:00 2.4 0.7 4.2 1.1 2.7 0.8 4.6 1.5 2.7 0.8 4.6 1.5 85 8 89 165 9.6 0.1 10.1 9.3 08/26/2006 06:40:00 2.7 0.6 4.2 1.1 3 0.6 4.2 1.5 3 0.5 4.2 1.9 71 10 88 165 9.6 0 10.1 9.3 08/26/2006 06:50:00 2.5 0.7 4.6 1.1 2.7 0.8 4.9 1.1 2.8 0.6 4.6 1.1 57 12 70 165 9.6 0.1 9.6 9 08/26/2006 07:00:00 2.3 0.7 3.8 0.7 2.3 0.8 3.8 0.4 2.4 0.8 4.2 0.7 43 12 65 165 9.6 0 9.8 9.6 08/26/2006 07:10:00 2.4 0.8 3.8 0.4 2.3 0.9 4.2 0.4 2.3 0.8 4.2 0.4 39 17 37 165 9.6 0.1 9.8 9 08/26/2006 07:20:00 3.1 0.8 4.9 1.1 3.2 0.9 4.9 1.1 3.3 0.7 4.9 1.9 46 8 43 165 9.6 0 9.6 9 08/26/2006 07:30:00 4.3 0.5 5.3 2.6 4.3 0.5 5.7 2.6 4.3 0.5 5.7 2.6 34 7 37 165 9.6 0 9.6 9 08/26/2006 07:40:00 4 0.6 5.3 2.3 3.8 0.7 5.3 1.9 4.1 0.6 5.3 2.6 22 8 25 165 9.6 0.1 9.8 9 08/26/2006 07:50:00 4.4 0.4 5.3 3.4 4.3 0.4 5.7 3.4 4.5 0.4 5.3 3 25 5 18 165 9.6 0 10.3 9 08/26/2006 08:00:00 4.5 0.4 5.3 3.4 4 0.8 5.3 1.5 4.8 0.4 5.7 3.4 19 8 31 165 9.4 0 9.6 9 08/26/2006 08:10:00 4.4 0.5 5.7 3.8 2.6 0.7 4.6 1.5 4.4 0.5 6.1 3.4 7 4 8 165 9.5 0 9.8 8.8 08/26/2006 08:20:00 4.9 0.6 6.5 3.4 3.5 0.8 5.7 1.5 4.8 0.6 6.1 3.4 7 7 8 165 9.6 0.1 9.8 9 08/26/2006 08:30:00 5.5 0.6 6.8 3.8 4.4 0.8 6.5 2.3 5.4 0.6 7.2 3.8 10 7 10 165 9.8 0 9.8 9.3 08/26/2006 08:40:00 5.8 0.6 7.2 4.2 4.9 0.9 6.8 2.3 5.7 0.7 7.2 4.2 13 6 25 165 9.8 0 9.8 9.3 08/26/2006 08:50:00 6 0.5 7.6 4.2 5.1 0.9 7.2 2.6 5.9 0.6 7.2 4.2 13 5 16 165 9.8 0 10.3 9.6 08/26/2006 09:00:00 5.6 0.6 7.2 4.2 4.6 0.9 6.5 2.3 5.6 0.6 7.2 4.6 13 7 7 165 9.9 0 10.6 9.6 08/26/2006 09:10:00 4.3 0.7 5.7 2.3 4.2 0.7 5.7 1.5 4.4 0.6 5.7 2.6 24 8 21 165 9.9 0 10.1 9.6 08/26/2006 09:20:00 3.7 1.3 6.1 1.5 3.9 1.3 6.5 1.9 3.7 1.2 6.1 1.5 76 23 105 165 10.1 0.1 10.3 9.6 08/26/2006 09:30:00 4 0.7 5.7 2.3 4.3 0.7 6.5 2.6 4.2 0.6 5.7 2.6 92 10 89 165 10.1 0.1 10.3 9.6 08/26/2006 09:40:00 4.2 0.7 5.7 2.3 4.4 0.7 5.7 2.6 4.2 0.7 6.1 2.6 89 7 87 165 10.1 0.1 10.3 9.6 08/26/2006 09:50:00 3.4 0.6 4.9 1.1 3.6 0.6 5.3 1.5 3.6 0.6 5.3 1.9 82 12 92 165 10.1 0.1 10.3 9.6 08/26/2006 10:00:00 3.6 0.6 4.9 2.3 3.9 0.6 5.3 2.3 3.7 0.6 4.9 2.3 81 11 96 165 10.1 0 10.6 9.8 08/26/2006 10:10:00 2.4 0.7 4.2 0.7 2.5 0.7 4.6 1.1 2.6 0.6 4.2 1.1 74 13 56 165 10.4 0 10.6 9.8 08/26/2006 10:20:00 3.1 1.2 6.5 0.4 3.2 1.2 6.8 0.4 3.2 1 6.1 1.5 76 15 71 165 10.5 0 10.9 9.8 08/26/2006 10:30:00 5.2 1.1 7.6 2.6 5.4 1.2 8 2.6 5.3 1.1 7.2 2.6 61 9 52 165 10.5 0 10.9 9.8 08/26/2006 10:40:00 4.5 1 6.8 1.9 4.6 1 7.2 2.3 4.4 1.1 6.8 1.9 54 17 68 165 10.5 0.2 10.9 9.8 08/26/2006 10:50:00 5.1 1.3 7.2 1.9 5.1 1.3 7.6 1.9 4.9 1.1 7.2 2.3 40 15 52 165 10.5 0.1 10.9 10.1 08/26/2006 11:00:00 6.2 1.3 9.5 3 5.9 1.3 9.1 3 6 1.2 9.1 2.6 23 10 27 165 10.5 0 10.9 10.1 08/26/2006 11:10:00 7.2 1 9.1 4.6 7.1 1 9.1 4.6 7.2 1 9.5 4.9 28 9 22 165 10.5 0 10.9 10.3 08/26/2006 11:20:00 7.6 1 9.5 4.9 7.4 1 9.5 4.9 7.5 1 9.9 5.3 24 6 27 165 10.6 0.2 10.9 10.3 08/26/2006 11:30:00 7.6 0.8 9.1 4.6 7.1 1 9.1 3.8 7.5 0.9 9.5 4.2 19 6 23 165 10.7 0.1 10.9 10.3 08/26/2006 11:40:00 7.7 0.7 9.1 5.7 7.3 0.9 9.1 4.9 7.5 0.7 9.1 5.7 20 7 26 165 10.5 0.1 11.1 10.3 08/26/2006 11:50:00 7.7 0.7 9.1 4.9 7.3 1 9.1 3.8 7.5 0.8 9.5 5.3 21 7 25 165 10.5 0.1 10.9 10.3 08/26/2006 12:00:00 7.8 1.1 9.9 4.9 7.6 1.2 9.9 3.8 7.7 1 9.9 4.9 22 8 26 165 10.5 0 10.9 10.1 08/26/2006 12:10:00 8 1 10.7 5.7 7.7 1.1 10.3 4.6 7.7 1.1 11.1 4.9 22 7 16 165 10.5 0.1 10.9 10.3 08/26/2006 12:20:00 7.9 1.1 10.3 4.6 7.7 1.2 10.3 4.6 7.7 1.2 10.3 4.6 26 8 29 165 10.3 0 10.6 9.8 08/26/2006 12:30:00 8.8 0.7 10.3 5.7 8.5 1 9.9 4.9 8.5 0.9 10.3 6.1 20 6 19 165 10.2 0.1 10.6 9.8 08/26/2006 12:40:00 8.5 0.9 10.7 5.7 8.2 1 10.3 4.9 8.3 0.9 10.3 6.1 21 6 19 165 10.3 0 10.6 9.8 08/26/2006 12:50:00 8 0.9 9.9 5.7 7.7 1 9.9 4.2 7.8 1 9.9 4.9 22 8 16 165 10.4 0.1 10.9 9.8 08/26/2006 13:00:00 8.3 0.9 9.9 5.3 7.9 1.1 10.3 4.9 8.2 0.9 9.9 6.1 19 6 21 165 10.7 0.1 10.9 10.3 08/26/2006 13:10:00 7.8 0.7 9.5 5.7 7.5 0.9 9.5 4.6 7.9 0.8 9.5 6.1 19 6 25 165 10.6 0.1 10.9 10.3 08/26/2006 13:20:00 7.3 0.8 9.1 4.9 6.6 1.2 9.1 3.4 7.3 0.8 9.1 5.3 18 7 29 165 10.6 0.1 10.9 10.3 08/26/2006 13:30:00 7.3 0.6 9.1 5.3 6.8 0.8 8.8 3.8 7.3 0.7 8.8 4.9 18 6 22 165 10.5 0 10.9 10.1 08/26/2006 13:40:00 6.9 0.7 8.8 4.6 6.4 0.9 8.4 3.4 6.8 0.7 8.4 4.9 17 7 25 165 10.7 0.1 11.1 10.3 08/26/2006 13:50:00 7 0.8 8.4 4.6 6.5 1 8.4 3.4 7.1 0.9 8.8 4.9 17 6 10 165 10.9 0 11.1 10.9 08/26/2006 14:00:00 7.1 0.6 9.1 5.3 6.5 1 8.4 3.8 7.1 0.7 8.8 5.3 16 6 18 165 10.8 0.1 11.1 10.6 08/26/2006 14:10:00 6.5 0.8 8.8 4.6 5.8 1.2 9.1 3 6.7 0.8 9.1 4.9 13 10 25 165 10.8 0.1 11.1 10.3 08/26/2006 14:20:00 6.3 0.7 8.4 4.6 5 1.1 8 2.6 6.4 0.7 8.4 4.9 7 8 7 165 10.9 0 11.1 10.3 08/26/2006 14:30:00 6.7 0.9 8.8 4.9 4.8 1 7.6 2.6 6.7 0.8 8.8 4.6 2 7 7 165 11 0.2 11.4 10.6 08/26/2006 14:40:00 6.6 0.8 8.8 4.2 5 1 7.2 2.6 6.6 0.7 8.8 4.6 8 6 0 165 10.9 0.1 11.4 10.6 08/26/2006 14:50:00 6.4 0.7 8 4.6 4.7 1 7.6 2.6 6.4 0.6 8 4.2 3 8 10 165 11 0.2 11.4 10.6 08/26/2006 15:00:00 6 0.9 8 3.4 4.3 0.8 7.6 2.3 6 0.9 8 3.8 359 9 8 165 11.2 0.2 11.7 10.9 08/26/2006 15:10:00 6.7 0.7 8.8 4.9 4.9 1.2 8 2.6 6.7 0.8 9.1 4.9 357 6 4 165 11.1 0 11.4 10.9 08/26/2006 15:20:00 6 0.7 8 3.8 4.3 0.8 6.8 2.3 6 0.7 8 3.8 1 6 8 165 10.9 0.1 11.1 10.6 08/26/2006 15:30:00 5.1 1 7.6 3 4 1 7.2 1.5 4.9 0.9 7.2 3 5 9 354 165 10.6 0.2 11.1 10.3 08/26/2006 15:40:00 5.3 0.9 7.6 3.4 4.5 0.9 6.8 2.3 5 0.9 7.2 3 7 13 354 165 10.5 0.3 10.9 9.8 08/26/2006 15:50:00 6.2 1.1 8.8 3.4 5.6 1.5 8.4 2.6 6.3 1.1 9.1 4.2 17 7 18 165 10.3 0.1 10.9 9.8 08/26/2006 16:00:00 7.5 0.5 8.8 6.1 6.5 0.9 8.4 4.2 7.3 0.7 9.5 5.7 14 5 14 165 10.5 0.1 10.9 10.3 08/26/2006 16:10:00 7.2 0.6 9.1 5.3 6.3 0.9 8.8 3.4 7.1 0.7 9.1 4.6 13 6 9 165 10.7 0 10.9 10.6 08/26/2006 16:20:00 6.7 0.6 8.4 4.6 5.5 1 8 3 6.7 0.6 8 4.9 12 6 15 165 10.5 0 10.9 10.3 08/26/2006 16:30:00 7.6 0.7 9.5 6.1 6.8 1 8.8 3.8 7.5 0.7 9.5 5.3 16 6 15 165 10.3 0 10.9 10.1 08/26/2006 16:40:00 7.7 1.1 10.3 5.3 6.7 1.6 10.3 3 7.5 1.1 10.7 5.3 14 7 28 165 10.3 0 10.6 9.8 08/26/2006 16:50:00 8.6 0.7 10.7 6.5 8.4 0.8 10.3 6.1 8.4 0.9 10.7 5.7 21 5 29 165 10 0.1 10.3 9.6 08/26/2006 17:00:00 7.5 0.5 8.8 5.7 7.2 0.7 8.4 4.2 7.3 0.7 8.8 5.3 19 4 25 165 10 0.1 10.3 9.6 08/26/2006 17:10:00 7.5 0.8 9.5 5.3 6.8 1.2 9.5 3.8 7.5 0.8 9.9 5.7 16 6 22 165 10.1 0 10.6 9.8 08/26/2006 17:20:00 7.4 0.5 8.8 5.7 6.4 0.9 8.4 3.8 7.4 0.7 8.8 5.3 13 4 14 165 10.2 0 10.6 9.8 08/26/2006 17:30:00 6.7 0.7 8.8 5.3 4.7 1 6.8 2.6 6.7 0.6 8.4 4.9 6 6 4 165 10.2 0 10.6 9.8 08/26/2006 17:40:00 6.6 0.9 9.9 4.9 4.6 0.9 7.2 2.3 6.4 0.9 9.5 4.6 360 6 1 165 10.4 0 10.6 10.3 08/26/2006 17:50:00 6.4 0.6 8 4.9 4.6 0.9 7.2 3 6.2 0.6 8 4.6 2 7 7 165 10.4 0 10.6 10.1 08/26/2006 18:00:00 5.9 1 8.4 3.4 4.5 1.2 7.6 2.3 5.7 0.8 8.4 3.4 358 9 360 165 10.5 0 10.6 10.1 08/26/2006 18:10:00 6.4 0.7 8.8 4.2 5.1 1.1 7.2 2.6 6.3 0.9 8.4 3.4 355 9 0 165 10.3 0 10.9 9.8 08/26/2006 18:20:00 6 0.8 8 4.2 5.4 1 8.4 3 5.8 0.8 8 4.2 351 7 358 165 10.2 0 10.3 9.8 08/26/2006 18:30:00 6.4 1 8.8 3 5.6 1.3 8.8 1.9 6.3 1 8.8 4.2 348 9 354 165 10.3 0 10.6 9.8 08/26/2006 18:40:00 5.9 0.5 7.2 4.2 4 0.9 6.8 2.3 6 0.5 7.2 4.9 360 6 353 165 10.3 0 10.6 9.8 08/26/2006 18:50:00 5.6 0.7 7.6 3.8 4.6 1.2 7.6 1.9 5.7 0.6 7.2 4.2 353 8 356 165 10.3 0 10.6 9.8 08/26/2006 19:00:00 5.4 0.6 6.8 3.8 3.7 1 6.8 1.9 5.7 0.7 7.2 4.2 5 7 21 165 10.4 0 10.6 9.8 08/26/2006 19:10:00 4.5 0.6 6.5 3.4 3.5 1.1 6.5 1.5 4.7 0.5 6.8 3.8 7 11 25 165 10.5 0 10.6 9.8 08/26/2006 19:20:00 4.5 0.7 6.1 3 3.8 1.1 6.1 1.5 4.7 0.7 6.5 2.6 17 8 30 165 10.4 0 10.6 9.8 08/26/2006 19:30:00 6.3 0.4 7.6 4.9 5.5 1 7.2 2.6 6.5 0.5 7.6 4.9 16 6 18 165 10.3 0 10.9 9.8 08/26/2006 19:40:00 6.2 0.5 8 4.9 5.6 0.9 8 3.4 6.2 0.5 7.2 4.9 18 6 32 165 10.4 0 10.6 9.8 08/26/2006 19:50:00 5.2 0.7 6.8 3.8 4.6 0.9 6.5 2.3 5.4 0.7 7.2 3.8 17 6 17 165 10.4 0 10.6 9.8 08/26/2006 20:00:00 7.1 0.9 9.5 4.2 6.1 1.3 8.8 3 7 0.9 9.5 4.6 15 6 13 165 10.4 0 10.9 9.8 08/26/2006 20:10:00 7.1 0.4 8 5.7 5.6 0.8 7.2 3.4 7 0.5 8.4 5.7 12 4 12 165 10.2 0.2 10.9 9.6 08/26/2006 20:20:00 6.9 0.5 8 5.7 4.8 0.8 7.2 3 6.9 0.6 8 4.6 6 6 7 165 10.1 0.1 10.3 9.6 08/26/2006 20:30:00 6.7 0.6 8 5.7 5 1.2 7.6 2.6 6.6 0.6 8.4 5.3 10 4 22 165 10.3 0 10.6 9.8 08/26/2006 20:40:00 6.9 0.5 8.8 5.7 5.8 1 8.4 3.8 6.8 0.6 8.4 4.9 14 6 25 165 10.4 0 10.9 10.1 08/26/2006 20:50:00 7.2 0.9 8.8 4.6 7 1 9.1 4.2 7 0.9 8.8 4.9 24 6 18 165 10.3 0 10.9 9.8 08/26/2006 21:00:00 7.4 0.4 8.8 6.1 6.5 0.9 8.4 4.2 7.3 0.5 8.8 5.7 15 4 22 165 10.2 0.1 10.6 9.8 08/26/2006 21:10:00 7.2 0.5 8.4 6.1 4.5 0.8 7.2 2.6 7.2 0.5 8 5.3 4 5 357 165 10.3 0 10.6 9.8 08/26/2006 21:20:00 6.8 0.7 8.4 4.9 4.5 0.8 6.8 3 6.8 0.7 8 4.6 6 5 6 165 10.4 0 10.6 9.8 08/26/2006 21:30:00 6.4 0.7 8.4 4.6 4.7 1.4 8 1.9 6.4 0.6 8 4.9 10 8 25 165 10.5 0.2 10.9 9.8 08/26/2006 21:40:00 5.5 0.7 7.2 4.2 4.1 0.8 6.1 2.3 5.5 0.7 7.2 3.8 9 6 12 165 10.4 0.1 10.6 9.8 08/26/2006 21:50:00 6.2 0.8 8 4.2 5.6 1.1 7.6 2.6 6.1 0.9 8 3.8 16 6 19 165 10.5 0.2 10.9 9.8 08/26/2006 22:00:00 6.3 0.9 8.4 4.6 5.5 1 8 3 6.2 1 8.8 4.2 15 5 9 165 10.5 0.1 10.9 9.8 08/26/2006 22:10:00 5.8 0.4 7.2 4.9 4.4 0.9 7.2 2.6 5.9 0.5 7.6 4.9 10 4 18 165 10.6 0.1 10.9 9.8 08/26/2006 22:20:00 4.8 0.5 6.1 3.8 4 0.8 5.7 1.9 4.9 0.5 6.1 3.4 13 3 15 165 10.6 0.1 10.9 9.8 08/26/2006 22:30:00 4.4 0.5 6.1 3 4 0.8 6.1 1.9 4.5 0.5 5.7 3 17 6 19 165 10.6 0.1 10.9 9.8 08/26/2006 22:40:00 5.3 1 7.2 3 5 1 6.8 2.6 5.2 1 7.2 3 19 8 14 165 10.7 0.1 11.1 9.8 08/26/2006 22:50:00 6.7 0.5 8 4.9 5.9 0.8 7.6 3.4 6.5 0.6 7.6 4.6 15 5 20 165 10.7 0.2 10.9 10.3 08/26/2006 23:00:00 6.5 0.8 8.8 4.2 6.1 1 8.8 2.3 6.3 0.9 8.8 3.8 19 6 25 165 10.7 0.2 11.1 10.1 08/26/2006 23:10:00 7.3 0.9 9.9 4.9 6.7 1 9.9 3.8 7 1 10.3 4.9 17 7 15 165 10.7 0.1 11.1 10.3 08/26/2006 23:20:00 7.2 1.1 9.5 4.6 6.7 1.2 9.5 3.8 6.8 1.1 9.5 4.6 19 8 14 165 10.7 0.1 10.9 10.1 08/26/2006 23:30:00 7.1 0.7 9.1 5.3 6 1 8.8 3 7 0.8 9.1 4.9 12 7 16 165 10.6 0.1 10.9 10.1 08/26/2006 23:40:00 7.5 0.8 9.1 5.7 6.2 1.1 9.1 3.4 7.3 0.9 9.5 5.3 12 7 19 165 10.5 0.1 11.1 9.8 08/26/2006 23:50:00 7.2 0.7 9.5 4.9 5.7 1.3 8.8 3 7.1 0.7 9.1 5.3 11 6 15 165 10.5 0.1 10.9 9.8 08/27/2006 00:00:00 6.3 0.7 8.4 4.2 4.4 0.8 7.2 2.6 6 0.7 8 4.2 3 6 12 165 10.5 0 10.9 9.8 08/27/2006 00:10:00 6.5 1 9.1 3.8 5.1 1.1 8 2.6 6.3 1 9.1 3.8 9 7 11 165 10.6 0.1 10.9 10.1 08/27/2006 00:20:00 6.7 0.8 8.8 3.8 5.1 1.1 8.4 2.6 6.6 0.9 8.8 4.2 5 8 15 165 10.6 0.2 10.9 10.1 08/27/2006 00:30:00 7.9 0.9 9.9 5.3 6.4 1.2 9.5 3.4 7.7 1 9.9 4.6 11 7 12 165 10.6 0.2 10.9 10.3 08/27/2006 00:40:00 8.1 0.7 9.5 5.3 6.5 1 8.4 3.8 7.9 0.8 9.9 5.7 10 6 7 165 10.6 0.2 10.9 10.1 08/27/2006 00:50:00 8.7 0.8 10.7 5.7 7.3 1.3 10.3 3.8 8.6 0.8 10.3 6.1 12 6 12 165 10.6 0.2 10.9 9.8 08/27/2006 01:00:00 8.3 0.7 9.9 6.5 6.6 1.3 9.5 3.4 8.1 0.7 9.9 6.1 11 6 14 165 10.4 0.1 11.1 9.8 08/27/2006 01:10:00 8.7 0.8 11.1 6.5 6.4 1.1 9.1 3.8 8.5 1 11.5 6.1 7 6 3 165 10.3 0.2 10.6 9.6 08/27/2006 01:20:00 7.9 1 11.1 5.3 6.9 1 10.3 3.8 7.7 1.1 11.1 4.9 15 7 10 165 10.3 0.2 10.6 9.8 08/27/2006 01:30:00 7.4 0.7 9.5 5.3 6.8 1 9.5 4.2 7.1 0.9 9.1 4.9 16 5 23 165 10.3 0.1 10.9 9.8 08/27/2006 01:40:00 7.6 0.7 9.5 6.1 6 1.5 9.1 3 7.4 0.7 9.1 5.7 10 7 12 165 10.3 0.1 10.9 9.8 08/27/2006 01:50:00 8.1 0.8 10.3 6.5 5.7 1.1 9.5 3.4 7.9 0.9 9.9 5.7 8 5 1 165 10.3 0.2 10.6 9.8 08/27/2006 02:00:00 7.2 0.7 9.1 4.9 5.9 1.2 8.8 3 7.1 0.7 9.1 5.3 12 6 8 165 10.3 0.2 10.6 9.6 08/27/2006 02:10:00 7.8 0.6 9.1 5.7 6.3 1 8.4 3.8 7.6 0.7 9.5 5.7 12 6 20 165 10.3 0.1 10.6 9.8 08/27/2006 02:20:00 8 0.8 9.9 6.5 5.7 1 8.8 3.4 8 0.7 9.5 6.1 8 5 12 165 10.3 0.2 10.6 9.6 08/27/2006 02:30:00 8.4 0.7 9.9 6.5 5.4 1 8.8 3.4 8.2 0.8 9.9 6.1 6 5 8 165 10.2 0.2 10.9 9.6 08/27/2006 02:40:00 7.8 0.9 9.5 6.1 4.9 1 8.4 3 7.7 1 9.9 5.7 4 5 6 165 10.1 0.1 10.9 9.6 08/27/2006 02:50:00 7.8 0.8 9.9 5.3 5.6 1.3 9.5 3.4 7.8 0.8 10.3 6.1 8 7 18 165 10.1 0.1 10.6 9.6 08/27/2006 03:00:00 6.3 0.7 8.8 4.6 4.4 1.5 7.6 1.9 6.3 0.7 8 4.6 5 9 11 165 10.1 0.1 10.3 9.8 08/27/2006 03:10:00 7.3 0.8 9.5 5.3 5.8 1.7 9.1 2.6 7.2 0.8 9.9 4.9 11 8 18 165 10.1 0 10.6 9.8 08/27/2006 03:20:00 7.2 0.9 9.5 4.9 5.2 1.4 8.4 2.6 7 0.8 9.1 4.6 356 6 353 165 10.2 0 10.6 9.8 08/27/2006 03:30:00 7.3 0.7 10.3 5.7 5.4 1.3 9.5 3 7.2 0.7 9.5 4.9 359 8 12 165 10.3 0 10.6 9.8 08/27/2006 03:40:00 7 0.7 8.8 5.3 5 1.1 9.1 3 6.7 0.7 8.8 4.9 360 7 352 165 10.4 0 10.6 9.8 08/27/2006 03:50:00 7 0.9 8.8 4.9 4.6 1 7.2 2.6 6.9 0.8 9.1 4.6 3 9 355 165 10.5 0 10.9 9.8 08/27/2006 04:00:00 7.3 1 9.1 4.2 6.2 1.2 8.8 3.8 7.3 1 9.5 4.6 11 9 16 165 10.7 0.1 10.9 9.8 08/27/2006 04:10:00 7.6 0.9 10.7 5.3 6 1.2 8.8 3.4 7.3 1 10.3 4.9 10 8 6 165 10.6 0.1 10.9 9.8 08/27/2006 04:20:00 8.5 0.7 9.9 6.8 7.5 1.1 9.9 4.2 8.2 1 10.3 6.1 15 6 18 165 10.5 0 10.9 9.8 08/27/2006 04:30:00 9 0.8 11.1 6.5 7.6 1.3 9.9 3.8 8.9 0.9 10.7 6.5 14 8 10 165 10.5 0 10.9 9.8 08/27/2006 04:40:00 8.1 0.9 10.3 6.1 5.9 1.2 9.1 3.4 8 1 11.1 5.7 5 8 8 165 10.4 0 10.9 9.6 08/27/2006 04:50:00 8.3 0.8 10.3 6.5 5.4 1 9.1 3.4 8 0.8 9.9 6.1 0 5 3 165 10.2 0.2 10.6 9.6 08/27/2006 05:00:00 7.2 0.9 9.5 5.3 5.6 1.1 8.8 3 7 1 9.5 4.9 2 11 28 165 10.2 0.2 10.6 9.6 08/27/2006 05:10:00 7.4 0.8 9.5 5.7 5.6 1.2 8.8 3 7.2 0.9 10.3 5.3 358 8 4 165 10.3 0.2 10.6 9.8 08/27/2006 05:20:00 7.1 1 10.3 4.6 6.4 1.3 8.8 2.6 6.7 1 9.1 4.6 347 9 355 165 10.3 0.1 10.6 9.6 08/27/2006 05:30:00 6.8 0.8 8.8 4.9 5.7 1.2 8 2.6 6.7 0.8 8.8 4.6 354 10 11 165 10.3 0.2 10.6 9.8 08/27/2006 05:40:00 7.3 1 10.7 4.9 5.9 1.5 10.7 3 7.1 0.9 9.9 4.9 359 10 26 165 10.3 0.2 11.1 9.8 08/27/2006 05:50:00 8.2 1 10.7 6.1 6.9 1.2 9.5 3.8 8.1 1.1 10.7 4.9 357 12 18 165 10.5 0.2 10.9 9.8 08/27/2006 06:00:00 8.5 0.8 11.5 6.5 6.9 1.6 11.1 3.4 8.3 0.9 10.7 6.1 356 7 347 165 10.5 0.2 10.9 9.8 08/27/2006 06:10:00 8.3 0.9 10.7 6.1 6 1.1 9.5 3.8 8.4 1 11.8 5.7 2 8 6 165 10.5 0.2 10.9 9.8 08/27/2006 06:20:00 8.2 0.8 11.1 6.1 6.1 1.2 9.1 3.8 8.1 0.9 10.7 6.1 359 7 8 165 10.5 0.2 10.9 9.8 08/27/2006 06:30:00 7.7 0.5 9.5 6.1 6.3 1.3 9.5 3.8 7.5 0.7 8.8 5.3 354 6 344 165 10.5 0.2 11.1 9.8 08/27/2006 06:40:00 7.8 0.9 9.9 5.7 5.3 0.9 8.4 3.4 7.5 0.9 9.5 5.3 359 5 3 165 10.5 0.2 10.9 10.1 08/27/2006 06:50:00 8 0.9 10.7 5.3 5.7 1.3 9.5 3.4 7.9 1 10.3 6.1 1 7 352 165 10.5 0.2 10.9 10.1 08/27/2006 07:00:00 7.3 0.8 9.1 5.7 5.1 1 8.4 3 7.2 0.8 9.1 4.9 5 6 2 165 10.5 0.2 10.9 10.1 08/27/2006 07:10:00 8 1 9.9 5.7 6.4 1.5 10.3 3 7.7 0.9 9.9 5.3 353 9 5 165 10.7 0.2 10.9 10.3 08/27/2006 07:20:00 6.8 0.8 9.1 4.9 4.6 1 7.6 2.3 6.6 0.8 8.4 4.9 2 6 5 165 10.7 0.1 10.9 10.3 08/27/2006 07:30:00 6.2 0.7 8.8 4.2 4.9 1 8 2.6 6 0.6 7.6 4.2 4 9 353 165 10.7 0.1 10.9 10.3 08/27/2006 07:40:00 7 0.8 9.9 4.9 5.1 1.1 8.4 2.6 6.7 1 9.5 4.6 359 6 9 165 10.8 0 11.1 10.3 08/27/2006 07:50:00 6.9 0.7 8.8 5.3 5.4 1.2 8.4 2.6 6.5 0.8 8.4 3.8 359 8 5 165 11 0 11.1 10.6 08/27/2006 08:00:00 6 0.7 7.6 4.2 5 1 7.6 2.3 5.7 0.7 7.2 4.2 353 6 351 165 11.3 0.1 11.4 10.9 08/27/2006 08:10:00 5.6 0.8 8.4 3.8 4.5 1 7.2 1.9 5.3 0.8 8.4 3.4 354 8 7 165 11.5 0 11.7 11.1 08/27/2006 08:20:00 5.7 0.9 8.8 3.8 5.2 1.2 8.8 2.3 5.5 1 8.8 3.4 348 8 349 165 11.3 0.1 11.7 10.9 08/27/2006 08:30:00 4.9 0.7 7.6 3.4 4.1 0.8 7.2 2.3 4.7 0.7 7.6 3 355 11 12 165 11.3 0 11.4 10.9 08/27/2006 08:40:00 5.6 1 8 3.4 4.2 1.1 7.2 1.9 5.4 0.9 7.6 3 3 10 2 165 11.3 0 11.4 10.9 08/27/2006 08:50:00 6 0.8 7.6 3 5.5 0.9 7.6 3 5.9 0.8 7.6 3 17 8 21 165 11.1 0 11.4 10.6 08/27/2006 09:00:00 6.2 0.5 7.2 4.9 5.2 1 7.2 2.6 6.2 0.6 7.6 4.6 14 6 25 165 11 0 11.1 10.9 08/27/2006 09:10:00 6.5 0.6 8.4 4.6 4.7 1 7.6 2.6 6.4 0.7 8.4 4.6 6 7 357 165 11.1 0 11.4 10.9 08/27/2006 09:20:00 5.9 0.7 8 4.2 5.1 0.9 7.2 2.3 5.8 0.7 8 4.2 351 9 3 165 11.5 0.1 11.9 10.9 08/27/2006 09:30:00 5.5 0.7 7.2 3.4 4.6 1 8 2.3 5.2 0.7 7.6 3.4 352 10 355 165 11.7 0 11.9 11.1 08/27/2006 09:40:00 5.5 1 8.8 3.4 4.5 1.1 8.4 2.3 5.3 1 8 3 354 9 359 165 11.7 0.1 12.2 11.1 08/27/2006 09:50:00 5.9 0.9 8.8 3.8 4.7 1.3 8 2.3 5.7 0.9 8.4 3.8 360 11 19 165 11.6 0.3 11.9 11.1 08/27/2006 10:00:00 6.5 1.3 9.5 3 4.9 1.4 9.1 1.9 6.5 1.3 10.3 3.4 5 9 15 165 11.2 0.2 11.7 10.9 08/27/2006 10:10:00 6.4 1 8.8 4.2 5.4 1 8 3 6.2 1 9.1 3.4 4 12 1 165 11.3 0.1 11.7 10.9 08/27/2006 10:20:00 5.8 1.3 9.1 3.4 5.1 1.5 9.5 1.9 5.4 1.3 8.8 2.6 354 10 353 165 11.5 0.2 11.9 10.9 08/27/2006 10:30:00 5.4 1.6 8.4 2.6 4.5 1.5 8 1.5 5.4 1.6 8.4 2.3 354 10 353 165 11.7 0.3 11.9 11.1 08/27/2006 10:40:00 6.6 1 9.1 4.2 6.1 1 8.4 3.8 6.3 0.9 8.4 4.2 347 9 5 165 12.2 0.2 12.7 11.4 08/27/2006 10:50:00 6.2 0.8 8.8 3.4 5.8 1 9.1 3 6.1 0.9 8 3.4 338 12 346 165 12.4 0.2 13 11.9 08/27/2006 11:00:00 5.7 0.9 8.4 3.8 5.5 1 8.4 3.4 5.6 1 8.4 3.4 346 13 22 165 13.1 0.2 13.5 12.5 08/27/2006 11:10:00 6.9 0.9 9.1 4.6 5 1.1 8.8 2.6 6.7 1 9.1 4.6 5 8 16 165 13.1 0.2 13.5 12.7 08/27/2006 11:20:00 5.4 1 7.6 3 4.4 1 6.5 1.9 5.3 1 8 3 2 12 16 165 12.7 0 13 12.5 08/27/2006 11:30:00 4.9 1.1 8.4 2.6 4 1.2 7.6 1.9 4.7 1 7.6 2.3 355 15 10 165 12.6 0 12.7 12.5 08/27/2006 11:40:00 5.4 0.7 7.6 3.4 4.3 1 6.8 2.3 5.5 0.7 7.2 3.8 10 9 11 165 12.4 0 12.7 12.2 08/27/2006 11:50:00 5.1 0.8 6.8 3 3.9 1 6.1 1.9 5.1 0.7 7.6 3 8 12 10 165 12.6 0 13 12.2 08/27/2006 12:00:00 5 1 8 3 3.7 1.1 6.8 1.5 4.9 1.1 8.8 3 3 9 7 165 13.4 0.3 13.8 12.2 08/27/2006 12:10:00 4.2 0.8 6.5 2.3 3.4 0.8 6.5 1.9 4.3 0.7 6.1 2.6 6 15 350 165 13.1 0.1 13.3 12.7 08/27/2006 12:20:00 2.4 0.6 3.8 0.4 2.3 0.6 4.2 0.4 2.4 0.7 4.2 0.4 15 24 23 165 12.9 0.1 13.3 12.5 08/27/2006 12:30:00 2.8 0.8 4.6 0.7 2.4 0.8 4.6 0.4 2.9 0.7 4.6 0.7 346 17 358 165 13.7 0.5 14.9 13 08/27/2006 12:40:00 2 0.8 4.2 0.4 2 0.8 4.2 0.4 2.1 0.7 4.2 0.4 328 17 336 165 14.8 0.2 15.5 14.1 08/27/2006 12:50:00 1.1 0.7 3.4 0.4 1.1 0.8 3.8 0.4 1.3 0.8 3.8 0.4 336 19 333 165 14.7 0 15.2 14.4 08/27/2006 13:00:00 0.7 0.4 2.3 0.4 0.7 0.5 2.3 0.4 0.7 0.5 2.3 0.4 289 33 217 165 14.7 0 15.2 14.6 08/27/2006 13:10:00 3 1.1 5.3 0.4 2.9 1.2 5.3 0.4 2.9 1 5.3 0.4 346 22 333 165 14.9 0.1 15.5 14.6 08/27/2006 13:20:00 2.1 1 4.9 0.4 1.9 1 4.2 0.4 2.3 1 4.6 0.4 15 33 9 165 14.8 0.3 15.5 14.6 08/27/2006 13:30:00 2.7 0.6 3.8 0.7 2.1 0.8 4.2 0.4 2.6 0.7 4.6 0.4 351 16 315 165 15.1 0.2 15.5 14.6 08/27/2006 13:40:00 2.4 0.9 5.7 0.7 2.1 0.9 5.3 0.4 2.2 0.8 4.6 0.4 345 22 360 165 15.6 0.2 16.3 15.2 08/27/2006 13:50:00 4.7 0.8 7.2 2.3 3.8 0.9 7.6 2.3 4.2 0.8 6.8 1.9 354 11 345 165 14.7 0.1 15.5 14.6 08/27/2006 14:00:00 5.1 1.1 8 2.6 4.1 1.2 7.6 1.9 4.6 0.8 6.5 2.6 356 11 349 165 14.4 0 14.6 14.4 08/27/2006 14:10:00 2.6 1.2 6.8 0.4 2.2 1 5.7 0.4 2.8 1.1 6.1 0.4 341 22 1 165 14 0.1 14.4 13.8 08/27/2006 14:20:00 3.3 1.7 8.4 0.7 3 1.5 8 0.7 3 1.2 6.8 0.4 344 22 25 165 14.4 0 14.6 14.4 08/27/2006 14:30:00 3.1 1.3 7.2 0.4 2.9 1.2 6.8 0.4 3 1.3 6.5 0.7 344 30 16 165 14.7 0.2 15.7 14.6 08/27/2006 14:40:00 3.2 1.6 6.5 0.4 2.9 1.4 6.1 0.4 3 1.3 6.5 0.4 1 41 356 165 16.1 0.3 16.8 15.5 08/27/2006 14:50:00 4.4 1.1 8.8 0.7 3.9 1.2 7.2 0.7 4.1 1 6.5 1.9 354 17 358 165 16.3 0.1 16.8 16 08/27/2006 15:00:00 4.7 1.7 9.1 1.5 4.3 1.7 9.9 1.5 4.6 1.7 9.5 1.5 346 12 346 165 16.4 0.3 16.8 16 08/27/2006 15:10:00 5.7 1.2 9.1 3 4.6 1.4 9.5 1.9 5.5 1.1 9.1 2.6 353 11 342 165 16 0.4 16.8 15.5 08/27/2006 15:20:00 6.1 1 8.8 3.4 5.3 1.2 8 2.6 5.7 0.9 8 3.4 350 12 350 165 16.6 0.3 17.1 16 08/27/2006 15:30:00 6.1 1.2 8.4 3.4 5.4 1 7.6 3 5.7 1 8.4 3 336 19 354 165 16.6 0.3 17.1 16 08/27/2006 15:40:00 5.8 1 8 3 5.7 0.9 8 3 5.3 1 7.6 2.3 319 14 315 165 17.7 0.1 18.2 17.1 08/27/2006 15:50:00 5.8 1 9.1 3.8 5.8 1 9.1 3.4 5.3 0.8 8 3 315 9 306 165 17.6 0 18.2 17.4 08/27/2006 16:00:00 6.4 0.9 8.4 4.2 6.3 0.9 8.4 4.2 5.7 0.8 8.4 3.4 315 17 296 165 17.5 0.1 18.2 17.4 08/27/2006 16:10:00 5.7 1 8.8 3.8 5.6 1 8.8 3.4 5.4 0.8 7.2 3 327 17 339 165 17.8 0 18.5 17.4 08/27/2006 16:20:00 6.1 1.1 8.8 3.8 6 1.1 9.1 3.4 5.5 0.7 7.6 3.8 314 10 287 165 17.3 0.1 17.7 17.1 08/27/2006 16:30:00 5.3 0.9 7.2 1.9 5.3 1 7.2 1.5 5.1 0.7 6.5 3 324 17 321 165 17.5 0 17.7 17.4 08/27/2006 16:40:00 6.6 0.9 8.4 4.2 6.6 0.9 8.4 4.2 5.5 0.9 7.6 3 302 8 303 165 17.2 0.4 17.7 16.6 08/27/2006 16:50:00 8 0.7 9.1 6.1 8 0.7 9.5 6.1 6.5 0.9 9.1 4.6 304 6 302 165 16.3 0 16.6 16.3 08/27/2006 17:00:00 8.2 0.8 9.9 5.7 8.2 0.8 9.9 6.1 6.3 0.8 8.4 4.6 303 5 312 165 15.9 0.2 16.6 15.7 08/27/2006 17:10:00 7.7 0.6 9.1 5.3 7.7 0.6 9.1 5.3 5.9 0.8 8 4.2 301 5 296 165 15.9 0 16.3 15.7 08/27/2006 17:20:00 7.5 0.7 9.1 5.7 7.6 0.7 9.5 6.1 5.9 0.8 8 3.8 303 6 305 165 15.5 0.3 16.3 15.2 08/27/2006 17:30:00 7.5 0.7 9.5 5.7 7.5 0.7 9.9 5.7 6.4 0.9 8.8 4.6 308 6 307 165 15.9 0 16.3 15.7 08/27/2006 17:40:00 7 0.9 9.1 4.9 7 0.9 9.5 4.9 6.1 0.9 8.8 4.2 309 6 305 165 16.1 0 16.3 16 08/27/2006 17:50:00 7.8 0.5 9.1 6.1 7.8 0.5 9.5 6.1 6.5 0.8 8.4 4.9 306 5 302 165 15.9 0 16.3 15.7 08/27/2006 18:00:00 7.3 0.6 8.8 5.3 7.3 0.6 8.8 5.7 6.3 0.8 8 4.2 307 6 301 165 15.9 0 16.3 15.7 08/27/2006 18:10:00 7.5 0.7 9.1 6.1 7.5 0.7 9.5 6.1 6 0.8 8.8 3.8 303 7 289 165 15.7 0.1 16 15.7 08/27/2006 18:20:00 6.9 0.6 8 4.6 6.9 0.6 8.4 4.6 5.6 0.7 7.2 3.8 302 6 298 165 15.7 0 16.3 15.5 08/27/2006 18:30:00 8 0.4 9.1 6.5 8.1 0.5 9.1 6.5 5.9 0.5 7.6 4.6 300 3 298 165 15.5 0 16 15.2 08/27/2006 18:40:00 6.6 0.7 8 4.9 6.6 0.7 8.4 5.3 5.3 0.7 7.6 3.8 301 5 308 165 15.4 0 15.7 15.2 08/27/2006 18:50:00 6.1 0.5 7.6 4.9 6.2 0.5 8 4.9 4.7 0.6 6.5 3.4 295 3 295 165 15.2 0 15.7 14.6 08/27/2006 19:00:00 5.8 0.4 6.8 4.9 5.8 0.4 6.8 4.6 4.5 0.5 6.5 3.4 297 6 294 165 15.2 0.1 15.5 14.6 08/27/2006 19:10:00 6.2 0.5 7.2 4.9 6.1 0.5 7.2 4.9 5.1 0.6 6.8 3.4 304 5 301 165 15.1 0 15.2 14.9 08/27/2006 19:20:00 7.3 0.7 8.8 5.7 7.3 0.7 8.4 5.7 6.5 0.8 8 4.6 307 4 303 165 14.7 0 15.2 14.6 08/27/2006 19:30:00 7.4 0.5 8.4 6.5 7.3 0.5 8.8 6.5 6.4 0.6 8.4 4.2 309 4 315 165 14.4 0 14.6 14.1 08/27/2006 19:40:00 7.5 0.6 8.8 5.7 7.4 0.6 8.8 5.7 6.2 0.7 8 4.6 307 4 305 165 13.9 0.1 14.4 13.3 08/27/2006 19:50:00 7 0.5 8.4 5.7 7 0.5 8.4 5.7 5.5 0.6 7.2 4.2 305 3 305 165 13.5 0.3 14.4 12.7 08/27/2006 20:00:00 7.2 0.7 9.1 5.3 7.2 0.7 9.1 5.3 5.4 0.6 7.6 4.2 302 4 302 165 12.9 0.1 13 12.5 08/27/2006 20:10:00 7.8 0.6 9.5 6.5 7.8 0.7 9.5 6.5 5.7 0.6 7.6 4.2 301 3 295 165 12.9 0 13.3 12.7 08/27/2006 20:20:00 7.7 0.7 9.5 6.1 7.7 0.7 9.9 6.1 5.7 0.7 8 4.2 300 5 294 165 13 0 13.3 12.7 08/27/2006 20:30:00 7.8 0.5 9.1 6.8 7.8 0.5 9.1 6.5 5.7 0.6 7.2 4.2 302 3 299 165 12.8 0 13 12.7 08/27/2006 20:40:00 8.1 0.7 9.9 6.5 8.2 0.7 9.9 6.5 6.1 0.7 8 4.2 304 4 291 165 12.6 0 12.7 12.5 08/27/2006 20:50:00 8.2 0.5 9.5 7.2 8.2 0.5 9.5 6.8 6.5 0.6 8 4.6 305 3 302 165 12.7 0 12.7 12.5 08/27/2006 21:00:00 8.7 0.7 9.9 7.2 8.7 0.7 10.3 6.8 6.4 0.6 8.4 5.3 304 3 303 165 12.5 0 12.7 12.5 08/27/2006 21:10:00 9.4 0.4 10.3 8 9.4 0.4 10.3 8 6.4 0.5 8 5.3 302 2 303 165 12.7 0 12.7 12.5 08/27/2006 21:20:00 9.3 0.3 9.9 8.4 9.3 0.3 10.3 8.4 6.5 0.5 8.4 5.3 302 2 300 165 12.5 0 12.7 12.5 08/27/2006 21:30:00 9.1 0.3 10.3 8.4 9.1 0.4 9.9 8 6.5 0.5 8 5.3 302 2 300 165 12.5 0 12.7 12.5 08/27/2006 21:40:00 9.3 0.5 10.7 8 9.4 0.5 10.7 7.6 6.8 0.5 8.4 5.3 304 2 304 165 12.4 0 12.7 12.2 08/27/2006 21:50:00 10.2 0.5 11.8 9.1 10.3 0.5 11.8 8.8 7.1 0.6 9.9 5.7 302 3 296 165 12.5 0 12.7 12.2 08/27/2006 22:00:00 10.4 0.5 11.8 9.1 10.5 0.5 11.5 9.1 7.2 0.6 8.8 5.7 302 3 302 165 12.6 0 12.7 12.5 08/27/2006 22:10:00 10.2 0.5 11.8 8.8 10.3 0.5 11.5 8.4 7.8 0.7 9.5 6.1 305 3 306 165 12.6 0 12.7 12.5 08/27/2006 22:20:00 10.7 0.6 12.6 9.1 10.7 0.6 12.2 9.1 8 0.8 11.1 6.1 305 3 305 165 12.5 0 12.7 12.2 08/27/2006 22:30:00 10.9 0.5 12.2 9.5 10.9 0.4 12.2 9.5 8.3 0.7 10.3 6.1 306 3 304 165 12.5 0 12.7 12.5 08/27/2006 22:40:00 11.2 0.6 13 9.1 11.2 0.6 13 9.5 8.2 0.8 11.1 6.1 305 3 307 165 12.5 0 12.7 12.2 08/27/2006 22:50:00 11.1 0.8 12.6 8.8 11 0.8 12.6 8.4 8.4 0.9 11.5 6.1 305 3 307 165 12.4 0 12.7 12.2 08/27/2006 23:00:00 10.8 0.6 12.6 9.1 10.8 0.6 12.6 9.1 8.8 0.9 11.1 6.8 307 4 307 165 12.3 0.1 12.5 11.9 08/27/2006 23:10:00 10.9 0.7 12.2 9.1 10.9 0.7 12.2 9.1 8.5 0.9 11.1 6.5 306 4 306 165 12.2 0.1 12.7 11.9 08/27/2006 23:20:00 11.5 0.7 13 8.8 11.4 0.7 13 8.8 8.8 0.8 11.1 6.8 305 3 310 165 12.3 0.1 12.5 11.9 08/27/2006 23:30:00 11.9 1.2 14.5 9.1 11.8 1.2 14.5 9.5 9.6 1 12.6 6.5 308 4 305 165 12.2 0.1 12.5 11.9 08/27/2006 23:40:00 11.6 0.9 13.7 9.5 11.4 0.9 13.3 9.5 9.7 1 12.6 7.2 309 4 311 165 12.1 0.1 12.5 11.9 08/27/2006 23:50:00 12.1 0.8 13.7 9.5 12 0.8 13.7 9.9 9.7 1 12.6 6.5 307 4 308 165 12.1 0.1 12.5 11.7 08/28/2006 00:00:00 11.4 1 14.1 9.1 11.3 1 14.1 9.1 9.3 1.3 13.3 6.1 307 5 306 165 12.2 0.1 12.5 11.9 08/28/2006 00:10:00 10.1 1.2 12.2 7.2 10 1.2 12.2 7.2 8.1 1.1 11.1 4.9 306 5 304 165 12.1 0.1 12.5 11.7 08/28/2006 00:20:00 7.5 1.3 9.9 3.8 7.5 1.2 10.3 3.8 5.8 1.3 8.8 2.3 303 8 305 165 11.8 0.1 12.2 11.4 08/28/2006 00:30:00 6.1 1.3 9.5 2.6 6.2 1.3 9.1 1.1 4.5 1.4 7.6 0.7 297 9 299 165 11.7 0.3 12.2 11.4 08/28/2006 00:40:00 7.5 1 10.3 4.2 7.5 1 10.3 4.6 5.8 1 8.8 2.6 300 7 301 165 11.9 0.1 12.2 11.4 08/28/2006 00:50:00 7.3 1 9.9 4.6 7.2 1 10.3 4.6 5.3 1.2 8 1.5 293 8 291 165 12.2 0 12.2 11.7 08/28/2006 01:00:00 8.6 1.3 11.1 5.3 8.6 1.2 11.1 5.7 7.2 1.2 11.1 4.2 290 8 296 165 11.9 0.1 12.2 11.7 08/28/2006 01:10:00 10.4 0.8 13 8.4 10.4 0.8 12.6 8.4 8.1 0.9 11.1 6.1 297 5 303 165 12.2 0.1 12.5 11.7 08/28/2006 01:20:00 10.7 0.8 13 9.1 10.8 0.7 13 8.8 7.4 0.7 9.9 5.7 300 3 298 165 12.3 0 12.5 11.7 08/28/2006 01:30:00 10.6 0.6 12.2 9.1 10.7 0.6 12.2 9.1 7.9 0.8 10.3 5.7 305 3 305 165 12.2 0.2 12.7 11.7 08/28/2006 01:40:00 10.3 0.7 12.2 8.8 10.3 0.7 11.8 8.4 8 0.9 10.7 6.1 305 5 305 165 12.2 0.2 12.5 11.7 08/28/2006 01:50:00 10.9 0.6 12.2 9.1 10.9 0.6 12.2 9.1 7.9 0.8 10.3 5.7 303 3 305 165 12.3 0.2 12.7 11.7 08/28/2006 02:00:00 10.6 0.6 11.8 8.4 10.6 0.6 12.2 8.4 7.7 0.7 9.9 6.1 303 4 305 165 12.3 0.2 12.5 11.9 08/28/2006 02:10:00 10.8 1 13 8 10.9 1 13 8 7.7 0.7 9.5 6.1 301 4 300 165 12.1 0.2 12.5 11.7 08/28/2006 02:20:00 11.6 0.7 13 9.5 11.6 0.7 13 9.5 8.1 0.6 9.9 6.1 301 3 301 165 11.9 0.2 12.2 11.4 08/28/2006 02:30:00 11.9 0.8 13.7 9.5 11.9 0.8 13.7 9.5 8.2 0.7 10.7 6.8 302 3 301 165 11.9 0.1 12.5 11.4 08/28/2006 02:40:00 11.3 0.7 13.3 9.5 11.3 0.7 13 9.5 8.1 0.8 10.7 6.5 303 3 305 165 11.9 0 12.5 11.4 08/28/2006 02:50:00 11.3 0.8 13.7 9.1 11.3 0.8 13.3 9.1 9.1 1 12.6 6.8 307 4 312 165 11.9 0 12.5 11.4 08/28/2006 03:00:00 11.1 0.8 12.6 8.8 11 0.8 13 8.4 9.3 1 11.5 6.5 307 4 307 165 11.9 0 12.2 11.4 08/28/2006 03:10:00 10.8 0.9 12.6 8.4 10.7 0.9 12.2 8.8 8 0.8 10.7 6.1 304 4 304 165 11.9 0.1 12.5 11.4 08/28/2006 03:20:00 10.7 0.6 12.6 9.1 10.7 0.6 12.6 9.1 7.7 0.7 9.5 6.1 301 3 298 165 11.9 0 12.2 11.7 08/28/2006 03:30:00 10.4 0.7 11.8 8.4 10.3 0.8 12.2 8 7.7 0.7 9.9 5.7 301 4 296 165 11.9 0 12.2 11.7 08/28/2006 03:40:00 7.8 1.2 9.9 4.6 7.7 1.2 9.9 4.6 6 1.1 8.4 1.9 296 7 298 165 11.7 0 12.2 11.7 08/28/2006 03:50:00 5.2 1.4 8.4 1.1 5.2 1.3 8.4 1.1 3.8 1.5 8 0.7 286 13 286 165 11.7 0 11.9 11.4 08/28/2006 04:00:00 4.9 0.9 8.4 2.6 5 0.8 8 3 3.9 0.9 6.5 1.5 292 11 289 165 11.7 0 11.9 11.7 08/28/2006 04:10:00 5.4 0.9 7.2 3.4 5.4 0.9 7.2 3.4 4 1 6.5 1.1 295 9 294 165 11.9 0 12.2 11.7 08/28/2006 04:20:00 5.6 0.8 7.6 3 5.6 0.8 7.6 3 4.2 0.9 6.5 1.5 298 7 298 165 11.9 0 12.2 11.7 08/28/2006 04:30:00 5.6 0.7 7.2 3.4 5.6 0.7 7.2 3.4 4.3 0.8 7.2 2.3 301 8 300 165 12 0 12.2 11.7 08/28/2006 04:40:00 5.8 0.9 7.6 3 5.8 0.9 7.6 3.4 4.4 0.8 6.8 2.3 301 8 306 165 12 0 12.2 11.7 08/28/2006 04:50:00 4.9 0.8 6.5 2.6 5 0.8 6.8 2.6 3.5 0.9 5.3 0.7 300 9 295 165 11.8 0 12.5 11.4 08/28/2006 05:00:00 5.1 1 7.2 2.3 5.1 1 7.2 3 3.7 1.2 6.5 0.7 295 10 295 165 11.7 0 11.9 11.4 08/28/2006 05:10:00 5.2 1 7.6 1.1 5.2 1 7.6 1.1 3.5 1.2 6.1 0.4 295 11 293 165 11.7 0 11.9 11.4 08/28/2006 05:20:00 6.9 0.6 8.4 5.3 6.8 0.6 8.4 5.3 5.3 0.8 7.6 3 297 5 297 165 11.8 0.1 11.9 11.4 08/28/2006 05:30:00 6.9 0.6 8 4.9 6.9 0.6 8 4.9 5.4 0.8 7.6 3 299 4 307 165 11.8 0 11.9 11.7 08/28/2006 05:40:00 7 0.8 9.1 4.9 6.9 0.7 8.8 4.9 5.4 0.8 7.6 3 297 5 292 165 11.7 0 11.9 11.4 08/28/2006 05:50:00 6 0.8 8.4 3.8 5.9 0.8 8.4 3.8 4.4 1 6.8 1.5 294 7 298 165 11.7 0 11.9 11.7 08/28/2006 06:00:00 7.5 1.1 9.5 4.9 7.4 1 9.9 4.9 5.7 1.2 8.8 3.4 295 5 294 165 11.9 0 12.2 11.7 08/28/2006 06:10:00 7.9 0.7 9.9 5.3 7.8 0.7 9.5 5.3 6.2 0.9 8 3.8 295 4 297 165 12.1 0 12.2 11.9 08/28/2006 06:20:00 9 0.8 10.3 6.5 8.8 0.8 10.3 6.1 6.7 0.8 9.1 4.6 299 3 298 165 12.2 0 12.5 11.9 08/28/2006 06:30:00 9 0.6 10.3 6.5 8.9 0.6 10.3 6.1 7 0.6 9.1 4.9 300 3 298 165 12.1 0 12.5 11.9 08/28/2006 06:40:00 8.4 0.6 9.9 6.8 8.2 0.6 9.9 6.8 6.4 0.7 8.4 4.2 299 3 304 165 11.9 0 12.2 11.7 08/28/2006 06:50:00 8.1 0.7 9.9 6.1 8 0.6 9.5 6.1 6.3 0.9 8.8 3.8 301 5 296 165 11.9 0 11.9 11.7 08/28/2006 07:00:00 8.4 0.9 10.3 5.3 8.3 0.9 10.3 5.3 6.6 0.9 9.1 4.2 301 4 299 165 12.1 0 12.5 11.7 08/28/2006 07:10:00 9.3 1.1 11.5 6.5 9.1 1 11.5 6.1 7.1 1 9.5 4.6 300 5 300 165 12.2 0 12.5 11.9 08/28/2006 07:20:00 10.4 0.6 11.8 8.8 10.3 0.6 11.8 8.4 7.8 0.7 9.9 6.1 300 3 299 165 12 0 12.2 11.7 08/28/2006 07:30:00 10.3 0.7 11.5 8 10.2 0.7 11.5 8 8 0.8 10.3 5.3 300 3 300 165 12.1 0.2 12.7 11.9 08/28/2006 07:40:00 7 1 9.5 3.8 7 1 9.5 4.2 5.6 1.2 8.8 2.3 301 8 304 165 13.1 0.3 13.5 12.2 08/28/2006 07:50:00 7.5 1 9.5 4.2 7.4 1 9.9 4.9 6 1.1 9.1 3.4 300 8 304 165 13.5 0.1 13.8 13 08/28/2006 08:00:00 7.2 1.3 9.9 4.2 7.2 1.2 9.9 4.2 5.8 1.4 9.5 2.3 302 7 302 165 13.7 0.1 14.1 13 08/28/2006 08:10:00 7 1 9.5 3 6.9 1 9.5 3.4 5.1 1.1 8.8 1.9 300 9 297 165 13.8 0.1 14.4 13.3 08/28/2006 08:20:00 5.6 1.2 8.4 1.9 5.6 1.2 8.4 1.5 4 1.2 7.6 0.4 296 13 303 165 14.2 0.1 14.6 13.5 08/28/2006 08:30:00 5.7 1.1 8 1.5 5.7 1.1 8 1.1 4.1 1.1 7.2 1.1 299 13 300 165 14.2 0 14.6 14.1 08/28/2006 08:40:00 5.6 0.8 8 3.4 5.5 0.8 8 3.4 4.3 0.9 7.6 1.9 302 9 315 165 14.6 0 14.9 14.1 08/28/2006 08:50:00 7.2 1 9.1 4.2 7.1 0.9 8.8 4.2 5.7 1.1 8.4 2.6 305 6 299 165 14.6 0 14.9 14.6 08/28/2006 09:00:00 8 0.6 9.9 6.5 7.9 0.6 9.9 6.1 6.8 0.9 8.8 4.6 308 6 309 165 14.4 0.2 14.9 14.1 08/28/2006 09:10:00 7.4 0.8 9.5 4.9 7.3 0.8 9.1 4.9 5.9 0.8 8.4 3.8 303 6 301 165 13.9 0.1 14.4 13.5 08/28/2006 09:20:00 8.3 0.6 9.9 6.8 8.3 0.6 9.5 6.8 7.2 0.8 8.8 4.2 308 4 309 165 13.8 0 13.8 13.5 08/28/2006 09:30:00 8.3 0.6 9.9 6.1 8.2 0.6 9.9 6.1 6.9 0.8 8.8 4.9 307 5 317 165 13.9 0 14.4 13.8 08/28/2006 09:40:00 6.4 0.9 8.8 3.4 6.5 0.9 9.1 3.4 5.3 1 9.1 2.6 305 7 308 165 14.5 0.3 15.2 14.1 08/28/2006 09:50:00 6.2 0.7 8.4 4.2 6.3 0.7 8.4 4.2 5 0.8 7.2 2.6 301 7 310 165 15.7 0.2 16.3 15.2 08/28/2006 10:00:00 6.1 0.9 8.8 3.8 6.2 0.8 8.8 3.8 5 0.9 7.2 2.3 305 6 305 165 15.4 0.2 16.3 15.2 08/28/2006 10:10:00 6.9 0.7 8.4 4.6 6.9 0.7 8.4 4.9 5.8 0.6 6.8 3.8 307 5 305 165 14.6 0 15.2 14.4 08/28/2006 10:20:00 6.9 0.5 8.4 5.7 6.9 0.5 8.4 5.3 6.4 0.6 8 4.6 310 4 307 165 14.5 0 14.9 14.4 08/28/2006 10:30:00 6.5 0.6 8 4.2 6.5 0.6 8 4.6 6.2 0.7 8 4.2 312 6 317 165 15 0.1 15.7 14.6 08/28/2006 10:40:00 7.1 0.7 8.8 5.3 7 0.8 8.8 5.3 5.7 0.7 8.4 4.2 304 5 303 165 14.9 0 15.7 14.6 08/28/2006 10:50:00 6 1 7.6 3.4 6 0.8 7.6 3.4 5.2 0.9 6.8 2.3 307 6 310 165 15.2 0.1 15.7 14.9 08/28/2006 11:00:00 5.7 0.7 7.6 4.2 5.9 0.6 8 4.2 5.7 0.8 8 3.4 313 5 314 165 15.6 0.2 16 15.5 08/28/2006 11:10:00 5.3 0.7 7.2 3.8 5.5 0.7 7.2 3.8 5 0.8 7.2 3 308 8 310 165 15.7 0 16 15.5 08/28/2006 11:20:00 5.1 0.7 6.5 3 5.3 0.7 6.8 3.4 4.9 0.8 6.8 3 314 9 309 165 15.9 0.3 16.8 15.5 08/28/2006 11:30:00 5.7 0.8 7.6 3.4 5.9 0.8 7.6 3.8 5.1 0.7 7.6 3 308 8 297 165 16.1 0.1 16.6 15.7 08/28/2006 11:40:00 6 0.8 8.4 4.2 6.2 0.8 8.8 4.6 5.2 1 7.2 3 306 7 298 165 15.6 0 16.6 15.5 08/28/2006 11:50:00 4.5 0.9 6.5 2.3 4.8 0.8 6.5 1.9 4 0.7 6.1 2.6 309 14 293 165 15.9 0.4 16.8 15.5 08/28/2006 12:00:00 4.7 0.9 6.8 2.6 4.9 0.8 6.8 3 4.4 0.9 6.8 2.3 318 9 309 165 16.8 0.1 17.4 16.6 08/28/2006 12:10:00 5.2 0.8 6.8 2.6 5.4 0.8 7.2 3.4 4.2 0.7 6.8 2.3 300 7 294 165 16.3 0.3 17.4 15.7 08/28/2006 12:20:00 4 0.9 6.1 1.1 4.3 0.8 6.1 1.5 3.5 1 6.5 1.1 307 19 310 165 16.6 0.4 17.4 15.7 08/28/2006 12:30:00 4.2 0.8 6.1 2.3 4.4 0.8 6.5 2.6 3.5 0.6 5.3 1.9 304 9 303 165 16 0.3 16.8 15.7 08/28/2006 12:40:00 4.3 0.8 6.5 2.3 4.5 0.8 6.5 2.6 4.1 0.7 5.7 2.3 315 9 313 165 16.6 0.3 17.1 15.7 08/28/2006 12:50:00 4.1 1 6.8 1.5 4.3 1 6.8 1.5 4 1 6.8 2.3 311 13 327 165 17.5 0.2 18.2 17.1 08/28/2006 13:00:00 3.5 0.9 5.3 1.1 3.9 0.7 5.7 2.3 3.1 0.9 5.3 1.1 300 19 277 165 17.7 0.2 18.2 17.4 08/28/2006 13:10:00 4.3 0.7 6.1 2.6 4.5 0.7 6.1 2.6 3.8 0.8 6.1 1.5 314 11 320 165 18.2 0 18.5 18 08/28/2006 13:20:00 3.2 0.9 5.3 0.7 3.6 0.8 5.7 0.7 3 0.9 5.7 1.1 300 20 327 165 18.1 0 18.5 17.4 08/28/2006 13:30:00 3.1 1.1 5.7 0.7 3.4 1 6.1 1.5 2.9 1 5.7 0.7 302 19 304 165 18.1 0 18.5 18 08/28/2006 13:40:00 2.3 0.8 4.6 0.4 2.7 0.8 4.6 0.4 2 1 4.6 0.4 309 22 308 165 18 0.2 18.5 17.4 08/28/2006 13:50:00 3.2 1 5.3 0.4 3.4 0.9 5.3 0.7 2.8 1 5.3 0.4 308 12 318 165 17.8 0.1 18.2 17.4 08/28/2006 14:00:00 1.8 0.8 4.2 0.4 2.2 0.7 4.6 0.4 1.6 0.6 3.4 0.4 300 20 304 165 17.4 0 17.7 17.1 08/28/2006 14:10:00 2 1 4.9 0.4 2.5 0.9 4.9 0.4 1.8 0.9 3.8 0.4 297 36 12 165 18.2 0.2 18.5 17.7 08/28/2006 14:20:00 1.4 0.9 3.4 0.4 1.8 1 4.2 0.4 1.4 0.8 3.4 0.4 295 98 285 165 18.2 0 18.5 17.4 08/28/2006 14:30:00 1.3 1 4.2 0.4 1.6 1 4.2 0.4 1.6 0.8 4.2 0.4 198 90 321 165 17.9 0.2 18.5 17.4 08/28/2006 14:40:00 1.1 0.7 2.6 0.4 1.5 0.8 3 0.4 1.7 0.7 3 0.4 153 17 159 165 17.7 0.7 18.5 16.3 08/28/2006 14:50:00 2.3 0.9 4.2 0.4 2.7 0.7 4.2 0.7 2.7 0.8 4.2 0.7 157 21 164 165 16.5 0.1 16.8 16.3 08/28/2006 15:00:00 2.6 0.6 4.6 1.1 2.9 0.5 4.2 1.5 2.9 0.6 4.2 1.1 156 15 165 165 16.1 0.2 16.6 15.5 08/28/2006 15:10:00 2.6 0.6 3.8 1.1 2.9 0.5 4.6 1.5 3 0.5 4.2 1.9 172 7 169 165 15.4 0 15.7 15.2 08/28/2006 15:20:00 2 0.6 3.8 0.4 2.4 0.6 4.2 1.1 2.6 0.5 4.2 1.1 156 17 148 165 15.8 0.1 16.3 15.5 08/28/2006 15:30:00 3 0.7 4.9 0.7 3.2 0.7 5.3 1.5 3.4 0.6 5.3 2.3 153 11 165 165 16.3 0 16.8 16 08/28/2006 15:40:00 2.1 1 4.9 0.4 2.4 0.8 4.9 0.4 2.6 0.8 4.9 1.1 160 15 142 165 16.1 0.2 16.8 15.7 08/28/2006 15:50:00 2.6 0.8 4.2 0.7 2.9 0.6 4.2 1.1 3.1 0.7 4.6 1.5 159 15 176 165 16.4 0.3 16.8 15.7 08/28/2006 16:00:00 2.4 0.5 3.8 0.7 2.6 0.5 3.4 1.1 2.8 0.4 3.8 1.5 177 10 163 165 15.7 0 16 15.7 08/28/2006 16:10:00 2.1 0.8 3.8 0.4 2.3 0.7 4.2 0.4 2.8 0.6 4.2 0.7 153 17 165 165 15.8 0 16 15.7 08/28/2006 16:20:00 2.8 0.7 4.6 1.1 2.9 0.6 4.6 1.5 3.1 0.6 4.6 1.9 157 9 146 165 15.9 0 16.3 15.7 08/28/2006 16:30:00 2.2 0.6 3.4 0.7 2.4 0.5 3.8 1.1 2.6 0.4 3.8 1.9 157 14 164 165 15.6 0 16 15.5 08/28/2006 16:40:00 2.7 0.4 3.8 1.1 2.9 0.4 3.8 1.5 3.1 0.4 4.2 1.9 144 9 160 165 15.8 0 16 15.7 08/28/2006 16:50:00 1.6 0.8 3.4 0.4 2 0.7 3.8 0.4 2.1 0.6 3.8 0.7 123 23 121 165 15.7 0.1 16.3 15.5 08/28/2006 17:00:00 1.8 1.3 4.6 0.4 1.9 1.5 4.6 0.4 1.5 1.1 4.2 0.4 254 47 299 165 16.5 0.3 17.1 16 08/28/2006 17:10:00 0.8 0.8 3.8 0.4 1 0.8 3.4 0.4 0.8 0.5 2.6 0.4 153 86 271 165 16.9 0.1 17.1 16.6 08/28/2006 17:20:00 1.5 1.1 3.8 0.4 1.8 1.1 4.2 0.4 1.7 0.8 3.8 0.4 181 64 303 165 15.8 0.4 16.8 15.5 08/28/2006 17:30:00 2.5 1 4.9 0.4 2.8 1 4.9 0.4 2 1 4.6 0.4 298 32 293 165 15.9 0.1 16.6 15.5 08/28/2006 17:40:00 2.6 1.8 5.7 0.4 2.8 1.8 6.1 0.4 2.1 1.3 4.6 0.4 278 58 301 165 15.9 0 16.3 15.7 08/28/2006 17:50:00 4.1 1.6 6.5 0.4 4.3 1.7 6.8 0.4 3.2 1.5 5.7 0.4 301 29 314 165 15.9 0 16.3 15.7 08/28/2006 18:00:00 4.8 1 6.5 2.3 5 0.9 6.8 2.6 3.9 1 6.5 0.7 308 11 312 165 15.8 0 16.3 15.7 08/28/2006 18:10:00 5.1 0.6 6.5 3.4 5.2 0.6 6.5 3.4 4.3 0.7 6.1 2.6 306 8 304 165 15.6 0 15.7 15.5 08/28/2006 18:20:00 6 0.6 7.2 3.8 6 0.6 7.6 4.2 4.9 0.6 6.8 2.6 305 6 301 165 15.5 0 15.7 15.5 08/28/2006 18:30:00 5.9 0.7 7.6 3.4 6 0.7 7.6 4.2 5.3 0.8 7.2 3 311 7 307 165 15.5 0 15.7 15.5 08/28/2006 18:40:00 5.5 0.8 7.2 2.6 5.6 0.8 7.2 3 4.7 0.8 6.5 2.6 308 9 302 165 15.2 0.1 15.5 15.2 08/28/2006 18:50:00 5.6 0.7 7.2 3.8 5.6 0.7 7.2 4.2 4.7 0.7 6.5 2.6 306 8 304 165 15 0 15.2 14.9 08/28/2006 19:00:00 5.8 0.7 8.4 4.2 5.9 0.7 8 4.2 5.2 0.7 7.2 3.4 309 6 296 165 14.8 0 15.5 14.6 08/28/2006 19:10:00 5.8 0.7 7.6 3.8 5.8 0.7 8 3.8 4.9 0.7 6.8 3 303 8 310 165 14.5 0 14.9 14.1 08/28/2006 19:20:00 5.9 0.9 8.4 3.4 6 0.9 8 3.8 4.8 0.9 7.6 3 300 9 307 165 14.2 0 14.6 14.1 08/28/2006 19:30:00 6 1.3 9.5 3.4 6.1 1.3 9.5 3.4 5.4 1.5 9.5 2.3 294 10 285 165 14 0 14.4 13.8 08/28/2006 19:40:00 6.9 1 9.1 4.6 7 1 9.5 4.9 5.5 1 8.4 3.8 299 7 304 165 13.9 0 14.4 13.5 08/28/2006 19:50:00 7.4 0.6 9.5 6.1 7.4 0.6 9.1 6.1 5.8 0.7 7.6 4.2 298 5 301 165 13.3 0.2 14.4 12.5 08/28/2006 20:00:00 8 0.7 9.5 6.1 8 0.7 9.5 6.1 5.9 0.7 8.8 4.2 300 5 299 165 12.9 0.2 13 12.5 08/28/2006 20:10:00 7.9 0.6 9.5 6.8 7.9 0.6 9.9 6.5 6 0.8 9.1 4.2 298 4 302 165 12.9 0.1 13 12.5 08/28/2006 20:20:00 7.8 0.6 9.5 6.1 7.8 0.7 9.1 6.1 6.2 1 9.1 4.2 297 4 305 165 12.9 0.1 13 12.5 08/28/2006 20:30:00 8.2 0.6 9.5 6.5 8.2 0.6 9.5 6.1 6.1 0.7 8 4.6 298 3 300 165 12.9 0.1 13 12.5 08/28/2006 20:40:00 8.8 0.4 9.5 7.6 8.7 0.4 9.9 7.6 6.9 0.8 9.1 5.3 305 4 301 165 12.7 0 13 11.9 08/28/2006 20:50:00 8.5 0.5 9.9 7.2 8.4 0.5 10.3 7.2 7.5 0.5 8.8 5.7 310 2 307 165 12.6 0 12.7 12.2 08/28/2006 21:00:00 7.6 0.5 8.8 5.7 7.5 0.6 8.4 5.7 6.8 0.6 8.4 4.6 311 3 310 165 12.3 0 12.5 12.2 08/28/2006 21:10:00 7 0.5 8 4.9 6.9 0.6 7.6 4.9 6.2 0.6 7.6 4.6 310 4 303 165 12.1 0 12.5 11.9 08/28/2006 21:20:00 6.6 0.5 7.6 4.6 6.5 0.5 7.6 4.6 5.7 0.6 7.2 4.2 309 5 309 165 12.1 0 12.2 11.9 08/28/2006 21:30:00 6.5 0.4 8 5.3 6.5 0.4 7.6 5.3 4.9 0.5 6.5 3.8 303 4 305 165 12.3 0 12.7 11.9 08/28/2006 21:40:00 6.5 0.5 8 5.3 6.5 0.5 8 5.3 4.7 0.5 7.6 3.8 299 3 295 165 12.5 0 12.7 12.5 08/28/2006 21:50:00 7.1 0.5 8.4 6.1 7 0.5 8.4 6.1 5.3 0.6 6.8 4.2 304 3 299 165 12.4 0 12.7 12.2 08/28/2006 22:00:00 7.2 0.7 9.5 5.3 7.1 0.7 9.5 4.9 5.5 0.7 7.6 3.4 304 4 302 165 12.4 0 12.5 12.5 08/28/2006 22:10:00 7.1 0.7 9.1 5.3 7 0.7 8.8 4.9 5.3 0.6 6.8 3.8 303 4 297 165 12.4 0 12.5 12.2 08/28/2006 22:20:00 6.8 0.7 8.8 4.9 6.7 0.7 8.4 4.9 5 0.6 6.8 3.8 303 4 301 165 12.5 0 12.7 12.2 08/28/2006 22:30:00 6.5 0.6 8 4.2 6.5 0.6 8 4.6 4.9 0.6 6.5 3.8 299 4 300 165 12.5 0 12.7 12.5 08/28/2006 22:40:00 6.9 0.7 8.4 4.9 6.9 0.6 8 4.9 5.2 0.7 7.6 3.8 299 4 299 165 12.5 0.1 12.7 12.2 08/28/2006 22:50:00 6.3 0.5 7.6 4.9 6.3 0.5 7.6 4.9 4.8 0.6 6.5 3 299 5 303 165 12.1 0 12.5 11.9 08/28/2006 23:00:00 6.2 0.5 7.2 4.9 6.2 0.4 7.2 4.9 4.7 0.5 6.5 3.4 301 5 305 165 12.5 0.1 12.7 12.2 08/28/2006 23:10:00 5.9 0.6 7.2 4.6 5.9 0.6 7.2 4.6 4.4 0.5 5.7 3 298 4 300 165 12.5 0 12.7 12.2 08/28/2006 23:20:00 6.1 0.7 8 4.2 6.1 0.7 7.6 4.6 4.6 0.7 6.8 3 298 4 296 165 12.6 0 12.7 12.5 08/28/2006 23:30:00 6.6 0.8 9.1 4.9 6.6 0.8 9.1 4.9 4.9 0.7 7.2 3 302 5 300 165 12.7 0 13 12.2 08/28/2006 23:40:00 6.9 0.9 8.8 4.9 6.9 0.8 8.8 4.9 5.3 0.8 7.6 3.4 302 5 304 165 12.5 0.1 12.7 12.2 08/28/2006 23:50:00 7.4 1 9.5 3.8 7.4 1 9.1 3.8 5.8 0.9 8.4 3.4 302 6 303 165 12.5 0.1 13 12.2 08/29/2006 00:00:00 7.5 0.8 9.5 5.3 7.3 0.8 9.5 5.3 5.6 0.8 8 3.8 302 5 303 165 12.5 0.1 13 12.2 08/29/2006 00:10:00 7.6 0.5 9.1 6.5 7.5 0.5 8.8 6.1 5.7 0.6 7.6 3.8 302 4 302 165 12.3 0.1 12.5 11.9 08/29/2006 00:20:00 7 0.7 9.1 5.3 6.9 0.8 8.8 4.9 5.5 0.7 7.2 3.4 305 5 307 165 12.3 0 12.5 11.9 08/29/2006 00:30:00 7.6 0.5 8.8 6.5 7.5 0.5 8.8 6.1 5.6 0.5 7.6 4.2 304 3 301 165 12.1 0 12.2 11.9 08/29/2006 00:40:00 7.7 0.6 9.5 6.1 7.7 0.6 9.5 6.1 5.8 0.7 8 3.8 303 4 300 165 12.1 0.1 12.5 11.9 08/29/2006 00:50:00 7.6 0.6 9.1 6.1 7.5 0.7 9.1 5.7 6.1 0.8 8 3.8 305 4 303 165 12.3 0 12.7 11.9 08/29/2006 01:00:00 7.6 0.3 8.4 6.5 7.5 0.3 8.4 6.5 6 0.6 7.2 4.6 306 2 307 165 12 0.1 12.2 11.7 08/29/2006 01:10:00 7 0.5 8 4.9 6.8 0.6 8 4.9 6.2 0.6 7.6 4.6 311 4 306 165 11.7 0 12.2 11.4 08/29/2006 01:20:00 6.1 0.6 7.6 4.9 5.9 0.5 7.2 4.6 5.3 0.7 6.8 3.8 311 4 318 165 11.7 0.2 11.9 11.4 08/29/2006 01:30:00 5.2 0.8 7.2 2.6 5.2 0.8 6.8 3 4.6 1 6.8 2.3 312 7 308 165 11.7 0.1 11.9 11.4 08/29/2006 01:40:00 4.1 0.5 5.3 2.6 4.2 0.5 5.7 3 3.6 0.6 4.9 2.3 308 7 308 165 11.9 0.3 12.5 11.4 08/29/2006 01:50:00 4.2 0.4 5.3 3 4.4 0.4 5.3 3.4 4 0.5 5.3 2.6 311 4 301 165 11.8 0.2 12.5 11.4 08/29/2006 02:00:00 4.9 0.5 6.5 4.2 5 0.5 6.5 4.2 4.4 0.6 6.1 3 309 5 315 165 11.6 0.2 11.9 11.1 08/29/2006 02:10:00 5 0.5 6.5 3.8 5.1 0.5 6.5 3.8 4.5 0.6 5.7 3 309 5 308 165 11.9 0.2 12.2 11.1 08/29/2006 02:20:00 5 0.5 6.5 3.4 5.1 0.5 6.1 3.8 4.1 0.6 5.7 2.6 304 6 305 165 12.1 0.1 12.5 11.7 08/29/2006 02:30:00 5.4 0.3 6.1 4.6 5.6 0.3 6.1 4.9 4.4 0.5 5.7 3 295 4 302 165 12 0.1 12.5 11.7 08/29/2006 02:40:00 5.4 0.5 6.1 3.8 5.5 0.4 6.5 4.2 4.8 0.6 6.1 3.4 292 5 287 165 12 0.1 12.5 11.7 08/29/2006 02:50:00 6.2 0.5 7.6 4.6 6.3 0.5 7.6 4.6 5.2 0.7 6.8 3 306 3 300 165 11.9 0.2 12.5 11.4 08/29/2006 03:00:00 5.5 0.4 6.8 4.2 5.5 0.4 6.8 4.2 4.9 0.5 6.1 3.4 309 4 308 165 11.8 0.3 12.2 11.1 08/29/2006 03:10:00 5.5 0.4 6.1 4.6 5.5 0.4 6.5 4.2 4.7 0.5 5.7 3 309 3 307 165 11.8 0.2 12.2 11.4 08/29/2006 03:20:00 4.1 0.9 5.7 1.9 4.1 0.9 5.7 1.9 3.6 0.8 5.3 1.9 307 5 313 165 11.7 0.2 12.2 11.4 08/29/2006 03:30:00 3 0.4 4.2 1.9 3 0.4 3.8 1.9 2.7 0.5 3.8 1.5 306 6 309 165 11.6 0 12.2 11.1 08/29/2006 03:40:00 3.5 0.3 4.2 2.3 3.5 0.3 4.2 2.6 2.7 0.4 3.4 1.5 301 4 302 165 11.8 0.2 12.2 11.4 08/29/2006 03:50:00 3.4 0.3 4.2 2.3 3.5 0.3 4.2 2.6 2.8 0.4 3.8 1.9 294 4 296 165 12 0 12.2 11.7 08/29/2006 04:00:00 3 0.4 3.8 1.9 3.1 0.4 4.2 1.9 2.8 0.6 4.2 1.9 288 3 288 165 11.9 0 12.2 11.7 08/29/2006 04:10:00 3 0.3 3.8 2.3 3 0.3 3.8 2.3 3 0.4 3.8 1.9 287 3 287 165 11.9 0 12.2 11.7 08/29/2006 04:20:00 2.7 0.4 3.4 1.1 2.8 0.4 3.4 1.1 2.5 0.5 3.8 1.1 288 7 287 165 12.1 0 12.2 11.4 08/29/2006 04:30:00 2.4 0.5 3.4 1.1 2.5 0.4 3.4 1.1 2.6 0.4 3.4 1.5 272 5 271 165 12.1 0 12.2 11.9 08/29/2006 04:40:00 1.7 0.5 3 0.7 1.9 0.4 3 0.7 2.2 0.4 3 1.5 266 7 271 165 12.2 0.1 12.5 11.9 08/29/2006 04:50:00 1.4 0.2 1.9 0.7 1.5 0.2 1.9 0.7 2 0.2 2.6 1.5 275 5 271 165 12.6 0 12.7 12.5 08/29/2006 05:00:00 1 0.2 1.5 0.4 0.8 0.3 1.5 0.4 1.5 0.3 1.9 0.7 294 10 282 165 12.5 0 12.7 12.2 08/29/2006 05:10:00 0.7 0.3 1.5 0.4 0.6 0.4 1.5 0.4 1.4 0.4 2.3 0.7 298 7 305 165 12.5 0 12.7 12.5 08/29/2006 05:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.9 0.3 1.5 0.4 290 0 165 165 12.6 0 12.7 12.5 08/29/2006 05:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.6 0.2 1.1 0.4 285 10 165 165 12.6 0 12.7 12.5 08/29/2006 05:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.8 0.2 1.5 0.4 253 18 165 165 12.7 0 13 12.5 08/29/2006 05:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.7 0.3 1.5 0.4 226 0 165 165 12.6 0 13 12.5 08/29/2006 06:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0.1 1.1 0.4 226 0 165 165 12.9 0 13 12.7 08/29/2006 06:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0.1 0.7 0.4 226 0 165 165 12.8 0 13 12.5 08/29/2006 06:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0.1 0.7 0.4 226 0 165 165 13.2 0.1 13.5 12.7 08/29/2006 06:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 226 0 165 165 13.7 0.2 14.4 13.3 08/29/2006 06:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0.2 1.1 0.4 223 1 165 165 14.1 0 14.4 13.8 08/29/2006 06:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.7 0.2 1.1 0.4 210 8 165 165 14.2 0.1 14.6 13.8 08/29/2006 07:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.9 0.2 1.1 0.4 201 2 165 165 13.9 0 14.4 13.5 08/29/2006 07:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 1 0.2 1.5 0.7 183 1 165 165 13.3 0.1 13.8 13 08/29/2006 07:20:00 0.7 0.4 1.5 0.4 0.4 0 0.4 0.4 1.3 0.3 1.9 0.7 177 4 173 165 13 0 13.3 13 08/29/2006 07:30:00 1.1 0.2 1.5 0.7 0.6 0.3 1.5 0.4 1.3 0.3 1.9 0.7 169 1 168 165 13.4 0.3 14.1 13 08/29/2006 07:40:00 1.4 0.2 1.9 0.7 1.2 0.2 1.5 0.4 1.6 0.2 2.3 0.7 174 3 176 165 14.2 0 14.6 13.8 08/29/2006 07:50:00 1.4 0.3 2.3 0.7 1.1 0.4 1.9 0.4 1.6 0.2 1.9 1.1 169 3 167 165 14 0.1 14.4 13.5 08/29/2006 08:00:00 1.4 0.3 1.9 0.4 1.1 0.4 1.9 0.4 1.6 0.3 2.3 0.7 172 3 174 165 14.1 0 14.4 13.5 08/29/2006 08:10:00 1.5 0.3 1.9 0.7 1.3 0.4 1.9 0.4 1.7 0.3 2.6 0.7 173 3 169 165 14.3 0.2 14.6 13.8 08/29/2006 08:20:00 1.5 0.3 2.3 0.7 1.2 0.4 2.3 0.4 1.7 0.4 2.6 0.4 182 8 175 165 14.7 0 14.9 14.6 08/29/2006 08:30:00 1 0.4 1.9 0.4 0.7 0.4 2.3 0.4 1.6 0.4 2.6 0.7 176 10 165 165 14.6 0.1 14.9 14.4 08/29/2006 08:40:00 1 0.5 2.3 0.4 0.7 0.5 2.3 0.4 1.5 0.4 2.6 0.7 174 13 190 165 14.2 0 14.6 14.1 08/29/2006 08:50:00 1.3 0.5 2.6 0.4 1 0.6 2.6 0.4 1.8 0.5 3.4 0.7 161 13 156 165 14.2 0 14.6 14.1 08/29/2006 09:00:00 1.2 0.5 2.6 0.4 1 0.6 2.6 0.4 1.8 0.5 3 0.7 163 15 153 165 14.4 0 14.6 14.4 08/29/2006 09:10:00 1 0.5 2.6 0.4 0.9 0.5 2.3 0.4 1.6 0.5 2.6 0.4 164 13 164 165 14.6 0 14.9 14.4 08/29/2006 09:20:00 1.1 0.4 2.3 0.4 0.8 0.5 2.3 0.4 1.7 0.4 2.6 0.7 159 8 173 165 14.8 0.1 15.2 14.6 08/29/2006 09:30:00 1.1 0.4 3 0.4 0.7 0.5 3 0.4 1.5 0.4 2.6 0.7 159 7 165 165 14.6 0 14.9 14.6 08/29/2006 09:40:00 0.8 0.5 1.9 0.4 0.6 0.4 1.9 0.4 1.5 0.5 3 0.4 160 12 174 165 14.8 0.2 15.5 14.6 08/29/2006 09:50:00 1.3 0.6 2.6 0.4 1.4 0.6 3 0.4 1.8 0.5 3.4 0.7 151 13 153 165 15 0.1 15.7 14.6 08/29/2006 10:00:00 1.8 0.6 3.4 0.4 2 0.6 3.4 0.7 2.2 0.5 3.4 1.1 148 15 146 165 15 0 15.2 14.9 08/29/2006 10:10:00 1.8 0.9 3.8 0.4 2 0.9 4.2 0.4 2.3 0.7 3.8 0.4 143 17 145 165 15.3 0.2 15.7 15.2 08/29/2006 10:20:00 2.1 0.7 3.8 0.4 2.3 0.7 4.2 0.4 2.5 0.5 4.2 1.1 140 16 130 165 15.6 0 16 15.5 08/29/2006 10:30:00 1.8 0.9 3.4 0.4 2.1 0.7 3.8 0.4 2.5 0.6 3.8 0.7 130 18 144 165 15.6 0.1 16.3 15.5 08/29/2006 10:40:00 1.2 0.9 3.4 0.4 1.5 0.9 3.4 0.4 2 0.6 3.8 0.7 141 18 106 165 15.5 0 16 15.2 08/29/2006 10:50:00 1.6 0.8 3.8 0.4 1.9 0.7 4.6 0.4 2.1 0.6 3.4 0.4 147 22 160 165 15.8 0.2 16.3 15.5 08/29/2006 11:00:00 1.6 0.7 3.4 0.4 1.9 0.7 3.8 0.4 2.3 0.5 3.4 1.1 141 19 142 165 15.9 0.1 16.3 15.7 08/29/2006 11:10:00 1 0.6 2.6 0.4 1.2 0.7 3 0.4 1.4 0.8 3 0.4 169 69 165 165 16.3 0.3 17.1 15.7 08/29/2006 11:20:00 1.8 0.8 3.8 0.4 2 0.8 4.2 0.4 2.1 0.8 3.8 0.4 135 21 136 165 17.1 0.1 17.4 16.8 08/29/2006 11:30:00 1.7 0.6 3.4 0.4 1.9 0.6 3.4 0.4 2.2 0.6 3.4 0.4 117 22 108 165 16.5 0.2 16.8 16.3 08/29/2006 11:40:00 2 0.7 3.4 0.4 2.3 0.6 3.8 0.4 2.4 0.7 3.8 0.4 113 22 105 165 16.3 0.2 16.8 15.7 08/29/2006 11:50:00 2.7 0.5 4.2 0.7 3 0.5 4.2 1.1 3 0.5 4.6 1.9 116 11 116 165 16.4 0 16.8 16.3 08/29/2006 12:00:00 2.2 0.7 3.8 0.7 2.5 0.6 4.2 1.1 2.6 0.7 4.2 0.7 99 23 125 165 16.1 0.2 16.8 15.7 08/29/2006 12:10:00 2.1 0.9 4.9 0.4 2.4 0.7 5.7 0.4 2.3 0.8 6.1 0.7 69 39 43 165 15.7 0 16 15.5 08/29/2006 12:20:00 0.8 0.6 2.6 0.4 1.2 0.7 2.6 0.4 1.3 0.7 3 0.4 2 102 305 165 16.4 0.1 16.8 15.7 08/29/2006 12:30:00 1 0.7 3 0.4 1.3 0.7 3.4 0.4 1.4 0.7 3.8 0.4 117 82 22 165 17 0.4 17.7 16.3 08/29/2006 12:40:00 1.3 0.8 3.8 0.4 1.8 0.8 3.8 0.4 1.9 0.7 3.8 0.4 97 51 147 165 17.1 0.3 17.7 16.8 08/29/2006 12:50:00 1.5 0.9 3.8 0.4 2 0.8 4.2 0.4 2.1 0.8 6.1 0.4 95 45 130 165 16.6 0.1 16.8 16.3 08/29/2006 13:00:00 2.6 0.9 4.9 0.4 2.9 0.7 4.9 1.1 2.9 0.7 4.9 1.5 52 20 66 165 15.7 0.2 16.3 15.5 08/29/2006 13:10:00 2 0.8 4.2 0.4 2.3 0.8 4.2 0.4 2.3 0.8 4.9 0.4 34 49 56 165 16 0.3 16.8 15.5 08/29/2006 13:20:00 2 0.8 3.4 0.4 2.4 0.7 3.8 0.4 2.4 0.8 4.6 0.4 89 38 46 165 16.2 0.4 16.8 15.2 08/29/2006 13:30:00 3.5 0.7 6.1 1.9 3.7 0.6 6.1 1.9 3.8 0.6 5.3 2.3 46 9 66 165 15 0.2 15.5 14.6 08/29/2006 13:40:00 4.3 0.5 5.3 3 4.4 0.5 5.7 3 4.5 0.5 5.7 3 44 6 49 165 14 0.1 14.6 13.5 08/29/2006 13:50:00 4.3 0.5 5.7 2.6 4.4 0.5 5.7 3 4.5 0.5 5.3 2.6 41 5 41 165 13.7 0 14.1 13.5 08/29/2006 14:00:00 4 0.4 4.9 2.6 4.1 0.4 5.3 2.6 4.3 0.5 5.3 2.6 40 6 41 165 13.9 0 14.1 13.5 08/29/2006 14:10:00 4 0.5 5.3 2.6 4 0.6 5.3 2.3 4.2 0.5 5.7 2.6 27 9 22 165 13.9 0.2 14.4 13.5 08/29/2006 14:20:00 4.1 0.5 4.9 2.6 4.3 0.5 5.3 2.6 4.4 0.6 5.3 2.6 34 6 32 165 14 0.1 14.4 13.8 08/29/2006 14:30:00 3.8 0.4 4.9 2.6 3.9 0.4 4.9 2.6 4 0.5 5.3 2.6 29 7 31 165 14.2 0 14.4 14.1 08/29/2006 14:40:00 3.8 0.4 4.9 2.6 4 0.4 4.9 2.6 4.2 0.4 4.9 2.6 33 6 40 165 14.5 0.1 14.9 14.1 08/29/2006 14:50:00 3.6 0.4 4.6 2.6 3.8 0.4 4.6 3 4 0.4 4.9 3 29 6 10 165 14.8 0 15.2 14.6 08/29/2006 15:00:00 3.1 0.5 4.6 1.9 3.3 0.4 4.6 1.9 3.5 0.5 4.6 2.3 27 9 10 165 14.8 0 15.2 14.6 08/29/2006 15:10:00 3.7 0.6 4.9 1.5 3.8 0.6 5.3 1.9 4 0.8 5.3 1.5 27 8 22 165 14.4 0.1 14.9 14.1 08/29/2006 15:20:00 4.5 0.5 5.3 3 4.5 0.5 5.3 2.3 4.8 0.5 5.7 3.4 24 7 9 165 13.9 0 14.4 13.5 08/29/2006 15:30:00 4.8 0.4 6.1 3.8 4.7 0.6 6.1 2.6 5.2 0.4 6.1 4.2 20 6 20 165 13.5 0 14.4 13.3 08/29/2006 15:40:00 4.4 0.4 5.3 3.4 4 0.8 5.3 1.9 4.8 0.5 5.7 3.4 16 7 19 165 13.4 0 13.5 13 08/29/2006 15:50:00 4.2 0.4 5.3 3.4 3.5 0.9 4.9 1.9 4.6 0.4 5.3 3.8 11 9 18 165 13.1 0 13.5 12.7 08/29/2006 16:00:00 3.5 0.3 4.6 2.6 2.5 0.5 4.2 1.5 4 0.3 4.6 3 4 6 12 165 13 0 13.3 12.7 08/29/2006 16:10:00 2.5 0.4 3.4 1.5 2.3 0.5 3.4 1.1 2.7 0.3 3.8 1.9 357 12 352 165 12.7 0 13.3 12.5 08/29/2006 16:20:00 1.6 0.5 3 0.7 1.8 0.4 3 1.1 2.2 0.5 3.4 1.1 347 12 0 165 12.5 0 12.7 12.2 08/29/2006 16:30:00 1.2 0.6 2.3 0.4 1.3 0.4 2.6 0.4 1.7 0.4 2.6 0.7 350 12 4 165 12.1 0 12.5 11.9 08/29/2006 16:40:00 0.5 0.2 1.5 0.4 1.1 0.3 1.9 0.4 1.2 0.3 1.9 0.4 312 20 288 165 12.3 0.1 12.5 11.9 08/29/2006 16:50:00 1.1 0.4 1.9 0.4 1.7 0.3 2.3 1.1 1.5 0.4 2.3 0.7 284 7 277 165 12.5 0.1 12.7 12.2 08/29/2006 17:00:00 0.7 0.3 1.5 0.4 1.3 0.3 1.9 0.7 1.5 0.4 2.3 0.4 281 1 282 165 12.8 0.2 13 12.5 08/29/2006 17:10:00 0.8 0.4 1.9 0.4 1.4 0.3 1.9 0.7 1.3 0.3 1.9 0.7 284 5 289 165 12.9 0.1 13 12.2 08/29/2006 17:20:00 0.9 0.3 1.5 0.4 1.4 0.2 1.9 0.7 1.4 0.2 1.9 0.7 306 5 317 165 12.8 0.1 13 12.2 08/29/2006 17:30:00 0.9 0.3 1.5 0.4 1.4 0.3 1.9 0.7 1.4 0.4 2.3 0.7 300 9 292 165 12.7 0.1 13 12.2 08/29/2006 17:40:00 0.6 0.3 1.5 0.4 0.9 0.5 1.9 0.4 1.5 0.3 2.3 0.7 279 3 292 165 12.7 0.1 12.7 12.2 08/29/2006 17:50:00 0.7 0.3 1.1 0.4 1.2 0.3 1.9 0.4 1.5 0.4 2.3 0.4 276 8 278 165 12.7 0 13 12.2 08/29/2006 18:00:00 1 0.5 1.9 0.4 1.3 0.6 2.3 0.4 1.5 0.5 2.3 0.4 239 12 242 165 12.6 0 12.7 11.9 08/29/2006 18:10:00 1 0.5 2.3 0.4 1.4 0.5 2.6 0.4 2 0.3 2.6 1.1 251 10 237 165 12.2 0 12.5 11.7 08/29/2006 18:20:00 0.6 0.4 1.9 0.4 0.8 0.5 2.3 0.4 1.4 0.6 2.6 0.4 259 24 239 165 12.3 0.1 12.5 11.7 08/29/2006 18:30:00 0.5 0.2 1.1 0.4 0.6 0.3 1.5 0.4 0.9 0.5 1.9 0.4 230 11 221 165 12.3 0.1 12.5 11.9 08/29/2006 18:40:00 0.7 0.4 1.9 0.4 0.9 0.5 1.9 0.4 1.1 0.3 1.9 0.7 224 3 227 165 12.2 0 12.5 11.7 08/29/2006 18:50:00 1.1 0.4 1.9 0.4 1.5 0.4 2.3 0.4 1.7 0.3 2.3 0.7 266 22 238 165 12.1 0 12.2 11.7 08/29/2006 19:00:00 0.9 0.3 1.9 0.4 1.2 0.4 1.9 0.4 1.3 0.3 2.3 0.4 286 4 296 165 12.3 0 12.5 12.2 08/29/2006 19:10:00 0.4 0.1 0.7 0.4 0.4 0.1 1.1 0.4 0.4 0.2 1.1 0.4 283 0 283 165 12.4 0 12.5 12.2 08/29/2006 19:20:00 0.6 0.3 1.1 0.4 0.6 0.3 1.5 0.4 1.1 0.5 1.9 0.4 321 29 333 165 12.3 0 12.5 11.9 08/29/2006 19:30:00 0.4 0.2 1.5 0.4 0.4 0.2 1.5 0.4 0.7 0.3 1.5 0.4 356 29 111 165 11.9 0.1 12.2 11.7 08/29/2006 19:40:00 1.3 0.5 2.3 0.4 1.6 0.5 2.3 0.4 1.6 0.6 2.6 0.4 125 20 130 165 11.7 0 11.9 11.4 08/29/2006 19:50:00 1.5 0.5 2.6 0.7 1.8 0.5 3 1.1 2 0.4 2.6 1.5 117 7 116 165 11.3 0 11.7 11.1 08/29/2006 20:00:00 1.8 0.3 2.6 1.1 2.1 0.3 2.6 1.1 2.1 0.3 2.6 1.1 123 4 118 165 11.1 0 11.4 10.9 08/29/2006 20:10:00 1.4 0.2 1.9 0.7 1.7 0.2 2.3 1.1 1.9 0.2 2.3 1.5 129 6 119 165 10.7 0 10.9 10.6 08/29/2006 20:20:00 2.1 0.4 3 1.1 2.3 0.4 3 1.5 2.3 0.3 3 1.5 143 4 147 165 10.7 0 10.9 10.6 08/29/2006 20:30:00 1 0.5 1.9 0.4 1.3 0.5 2.3 0.4 1.6 0.3 2.3 0.7 135 5 139 165 10.8 0 11.1 10.9 08/29/2006 20:40:00 0.9 0.3 1.5 0.4 1 0.5 1.9 0.4 1.5 0.2 1.9 0.7 127 2 128 165 10.9 0 11.1 10.9 08/29/2006 20:50:00 1.5 0.4 2.3 0.7 1.8 0.4 2.6 1.1 2 0.3 2.6 1.5 125 4 129 165 11.1 0 11.4 10.9 08/29/2006 21:00:00 2.2 0.3 3 1.5 2.5 0.3 3.4 1.5 2.5 0.3 3.4 1.9 130 5 130 165 11.1 0 11.4 10.9 08/29/2006 21:10:00 2.2 0.3 2.6 1.5 2.5 0.3 3 1.9 2.5 0.2 3.4 1.9 124 6 126 165 11.1 0 11.4 10.9 08/29/2006 21:20:00 2.2 0.6 3.4 0.7 2.5 0.6 3.8 1.1 2.5 0.5 3.4 1.5 116 7 116 165 11.1 0 11.4 10.9 08/29/2006 21:30:00 1.9 0.5 3.4 0.7 2.2 0.4 3.4 0.7 2.4 0.3 3.4 1.5 132 8 144 165 10.9 0 11.1 10.9 08/29/2006 21:40:00 2.1 0.7 3.8 1.1 2.4 0.6 4.6 1.1 2.6 0.6 4.2 1.5 130 12 120 165 10.8 0 11.1 10.6 08/29/2006 21:50:00 2.8 0.4 3.8 1.9 3 0.4 4.2 2.3 2.9 0.4 4.2 1.9 126 11 142 165 10.7 0.1 11.1 10.3 08/29/2006 22:00:00 2.7 0.5 4.2 1.5 2.9 0.5 4.2 1.9 3 0.5 4.6 1.9 128 12 103 165 10.5 0.2 10.9 10.3 08/29/2006 22:10:00 3.2 0.5 4.6 1.9 3.4 0.5 4.6 2.3 3.3 0.5 4.6 1.9 126 9 135 165 10.4 0 10.9 10.3 08/29/2006 22:20:00 3.5 0.6 4.9 1.9 3.7 0.5 4.9 2.3 3.7 0.5 4.6 2.3 139 11 136 165 10.3 0 10.6 10.1 08/29/2006 22:30:00 4.3 0.5 5.7 3.4 4.5 0.5 5.7 3.4 4.4 0.5 6.1 3.4 135 9 133 165 10.3 0 11.1 10.1 08/29/2006 22:40:00 4.8 0.7 7.2 3 4.8 0.7 6.8 3 5 0.7 7.2 3.4 151 8 153 165 10.3 0 10.6 9.8 08/29/2006 22:50:00 5.4 0.8 6.8 3.8 5.5 0.7 6.8 3.8 5.7 0.8 7.2 3.4 151 9 159 165 10.3 0 10.6 9.8 08/29/2006 23:00:00 4.9 0.7 6.5 3.4 5 0.6 6.5 3.4 5.1 0.7 6.8 3.4 137 7 148 165 10.1 0.2 10.6 9.8 08/29/2006 23:10:00 3.7 0.3 4.6 3 3.9 0.3 4.6 3.4 3.9 0.3 4.9 3 129 6 125 165 10 0.2 10.3 9.6 08/29/2006 23:20:00 3.9 0.4 4.9 2.6 4 0.4 4.9 3 4.2 0.4 5.3 3.4 132 4 128 165 10 0.3 10.3 9.6 08/29/2006 23:30:00 4.7 0.4 5.7 3.8 4.8 0.4 6.1 3.8 4.9 0.5 5.7 3.4 143 6 142 165 10 0.3 10.3 9.6 08/29/2006 23:40:00 4.5 0.4 5.3 3.4 4.6 0.4 5.3 3.8 4.7 0.4 5.7 3 140 4 142 165 10 0.2 10.3 9.6 08/29/2006 23:50:00 4.3 0.4 5.3 3 4.4 0.4 5.3 3.4 4.4 0.4 5.3 3.4 143 5 150 165 10.1 0.2 10.6 9.6 08/30/2006 00:00:00 4.9 0.3 5.7 4.2 4.9 0.3 5.7 4.2 5 0.4 6.1 3.8 145 5 150 165 10.1 0.2 10.3 9.6 08/30/2006 00:10:00 5.5 0.6 6.8 3.8 5.6 0.6 6.8 3.8 5.6 0.6 6.8 3.8 142 6 136 165 10.1 0.1 10.3 9.8 08/30/2006 00:20:00 5.7 0.7 7.2 3.8 5.8 0.7 7.2 3.8 5.7 0.7 7.2 3.8 143 6 145 165 10.1 0 10.6 9.8 08/30/2006 00:30:00 6.7 0.7 8 4.9 6.8 0.7 8 4.9 6.7 0.7 8 4.9 140 4 132 165 10.2 0 10.6 9.8 08/30/2006 00:40:00 6.8 0.4 8 5.3 6.9 0.4 8.4 5.3 6.8 0.5 8 5.3 141 4 139 165 10.2 0 10.9 10.1 08/30/2006 00:50:00 6 0.6 7.6 4.2 6.1 0.6 7.6 4.6 6 0.7 8 3.8 137 6 136 165 10.2 0 10.6 10.1 08/30/2006 01:00:00 6.5 0.7 8 4.6 6.6 0.7 8 4.6 6.2 0.8 8 3.8 130 6 122 165 10.2 0 10.6 10.1 08/30/2006 01:10:00 7.6 0.6 9.1 6.1 7.8 0.6 9.1 5.7 7.5 0.7 9.1 5.3 124 5 132 165 10.4 0 10.6 10.3 08/30/2006 01:20:00 7.5 0.5 9.1 6.1 7.7 0.6 9.5 6.1 7.4 0.6 8.8 4.9 126 5 129 165 10.5 0 10.9 10.3 08/30/2006 01:30:00 7.8 0.7 9.9 6.1 7.9 0.8 10.3 6.1 7.8 0.7 9.9 5.7 126 6 138 165 10.6 0 10.9 9.8 08/30/2006 01:40:00 7.6 0.7 9.5 5.7 7.7 0.8 9.9 5.7 7.4 0.7 9.1 5.3 124 5 129 165 10.7 0 10.9 10.6 08/30/2006 01:50:00 7.6 0.7 9.9 6.1 7.8 0.7 10.3 6.1 7.4 0.8 9.9 5.7 128 6 123 165 10.7 0 10.9 10.6 08/30/2006 02:00:00 8.6 0.9 11.1 6.5 8.6 1 11.1 6.5 8.4 0.9 10.7 6.5 125 5 129 165 10.7 0 10.9 10.6 08/30/2006 02:10:00 9.1 0.7 11.5 6.8 9.2 0.8 11.5 6.1 9 0.8 11.1 6.5 130 6 131 165 10.7 0 11.1 10.6 08/30/2006 02:20:00 8.6 1 11.5 6.5 8.6 1 11.5 6.5 8.3 1 10.3 6.1 131 6 145 165 10.8 0 10.9 10.3 08/30/2006 02:30:00 9.6 1.2 12.6 7.2 9.6 1.2 12.6 6.8 9.2 1.3 12.2 6.5 132 7 130 165 10.8 0 11.1 10.3 08/30/2006 02:40:00 9.6 1.1 13 6.8 9.7 1 12.6 6.5 9.2 1.1 12.2 6.1 135 7 135 165 10.9 0 11.4 10.3 08/30/2006 02:50:00 10.4 0.9 13 8.4 10.5 0.9 13.3 8.4 10.2 1.1 12.6 7.6 130 7 136 165 10.9 0 11.1 10.3 08/30/2006 03:00:00 10.3 1.2 13 7.6 10.4 1.2 13 7.6 10 1.1 13.3 6.8 133 7 136 165 10.9 0 11.1 10.3 08/30/2006 03:10:00 10.5 1.1 13.7 7.6 10.5 1.1 13.7 7.6 10.1 1.2 13.7 6.8 136 6 135 165 10.9 0 11.1 10.3 08/30/2006 03:20:00 10.5 1.1 12.6 6.8 10.6 1.1 12.6 6.8 10.3 1.1 12.6 7.2 134 7 133 165 10.9 0 11.1 10.3 08/30/2006 03:30:00 10.2 1 13.3 8 10.4 1 13.3 8 9.9 1 12.6 7.6 132 7 139 165 10.9 0 11.1 10.6 08/30/2006 03:40:00 11.4 1.1 14.9 9.1 11.6 1.1 14.9 9.1 11.1 1.2 14.5 8 125 6 126 165 10.9 0 11.4 10.6 08/30/2006 03:50:00 11.4 1.1 14.1 8.8 11.6 1.1 14.5 8.8 11.1 1.2 14.1 7.2 123 6 118 165 10.9 0 11.1 10.6 08/30/2006 04:00:00 11.2 1.2 14.5 7.6 11.4 1.2 14.5 7.6 10.8 1.4 14.5 7.6 125 7 126 165 11 0 11.1 10.6 08/30/2006 04:10:00 11.2 1.1 13.7 8 11.3 1.1 14.1 8.4 10.8 1.1 14.1 8 127 6 130 165 10.9 0 11.1 10.6 08/30/2006 04:20:00 10.7 1 13.7 7.6 10.9 1.1 14.1 7.2 10.5 1.2 13.7 7.2 123 6 114 165 10.9 0 11.1 10.6 08/30/2006 04:30:00 10.4 1 13.7 7.6 10.6 1 14.1 7.6 10 1.1 13.3 7.2 122 5 125 165 10.9 0 11.1 10.6 08/30/2006 04:40:00 10.8 0.9 13.7 8.8 11 0.9 13.7 9.1 10.4 1 13.3 8.4 121 5 119 165 10.9 0 11.1 10.6 08/30/2006 04:50:00 10.6 0.9 13.7 8 10.8 0.9 13.3 8.4 10.4 1.1 13.3 7.6 123 6 118 165 11 0 11.1 10.9 08/30/2006 05:00:00 10.5 1.1 13.3 8 10.7 1.1 13.3 8.4 10.4 1.1 13.3 7.6 123 6 119 165 10.9 0 11.1 10.9 08/30/2006 05:10:00 10.7 1.1 13.3 7.2 10.9 1.1 13.3 6.8 10.3 1.2 13.3 6.1 122 6 116 165 10.9 0 11.1 10.9 08/30/2006 05:20:00 10.5 1.2 13.7 7.2 10.7 1.2 14.1 6.8 10.1 1.1 12.6 6.8 122 5 118 165 10.9 0 11.1 10.9 08/30/2006 05:30:00 10 0.9 12.6 7.2 10.2 0.9 12.6 7.6 9.8 0.9 12.2 6.8 120 5 123 165 10.9 0 11.4 10.9 08/30/2006 05:40:00 9.7 1 11.8 6.1 9.9 1 12.2 6.1 9.4 1.1 12.6 6.5 117 6 119 165 10.9 0 11.1 10.9 08/30/2006 05:50:00 9.4 1.1 12.2 6.8 9.6 1.1 12.6 6.1 9 1.1 11.8 4.9 115 6 113 165 11 0 11.1 10.9 08/30/2006 06:00:00 9.5 0.7 11.5 7.2 9.7 0.7 11.8 7.6 9 0.9 11.1 6.5 110 5 90 165 11 0 11.1 10.9 08/30/2006 06:10:00 10.2 1 13.3 8 10.4 1 13.7 8 9.9 1.2 12.6 6.8 109 5 111 165 11 0 11.4 10.9 08/30/2006 06:20:00 9.9 1 12.6 7.6 10.1 1 12.6 8 9.5 1.1 11.8 6.8 109 6 108 165 11 0 11.1 10.9 08/30/2006 06:30:00 10.8 1.1 13.3 7.2 11 1.2 13.7 6.8 10.1 1.3 13.3 5.7 105 6 102 165 10.9 0 11.4 10.9 08/30/2006 06:40:00 10.7 0.9 12.6 7.2 10.9 0.8 12.6 8.4 10.1 1 12.6 7.6 104 5 104 165 10.9 0 11.1 10.9 08/30/2006 06:50:00 10.9 1 12.6 6.8 11.1 1 13.3 7.6 10.1 1.1 12.2 6.8 102 5 102 165 10.9 0 11.1 10.9 08/30/2006 07:00:00 10.7 0.8 12.6 7.2 10.9 0.8 13 7.2 10.2 1 12.2 6.8 103 5 106 165 11 0 11.1 10.9 08/30/2006 07:10:00 10.7 0.8 13 7.6 10.9 0.8 13 7.6 9.8 1 12.2 6.5 102 5 108 165 11 0 11.1 10.9 08/30/2006 07:20:00 9.5 1 11.8 6.5 9.8 1.1 12.2 6.5 8.8 1.2 11.5 5.3 99 7 106 165 11 0 11.1 10.9 08/30/2006 07:30:00 10.5 1.1 13.3 6.8 10.7 1.1 13.3 6.8 9.8 1.1 12.2 6.5 101 6 92 165 11 0 11.1 10.9 08/30/2006 07:40:00 9.9 1.1 12.6 6.8 10.1 1.1 13 6.5 9.3 1.2 12.6 6.1 100 6 100 165 11 0 11.1 10.9 08/30/2006 07:50:00 10.4 1 13 6.8 10.6 1 13.3 6.8 9.6 1.3 12.6 6.1 101 5 102 165 11.1 0 11.1 10.9 08/30/2006 08:00:00 10.5 0.9 12.6 7.6 10.7 0.9 12.6 7.6 9.7 1 12.6 7.2 101 5 99 165 11 0 11.1 10.9 08/30/2006 08:10:00 10.5 1.2 13 6.8 10.7 1.2 13 6.8 9.8 1.2 13 6.1 99 6 100 165 11 0 11.1 10.9 08/30/2006 08:20:00 10.5 1 13 6.8 10.7 1.1 13.3 7.2 9.8 1.2 12.2 6.5 101 6 100 165 11.1 0 11.1 10.6 08/30/2006 08:30:00 10.4 1.2 13 5.3 10.6 1.2 13.3 6.1 9.8 1.1 12.2 6.1 101 6 99 165 11.1 0 11.1 10.6 08/30/2006 08:40:00 10.2 1 12.2 6.1 10.4 1.1 12.2 6.5 9.4 1.2 12.2 5.7 101 6 102 165 11.1 0 11.1 10.6 08/30/2006 08:50:00 9.9 1.1 12.2 6.1 10.1 1.2 12.6 5.7 9.3 1.2 11.5 6.1 97 6 91 165 11.1 0 11.1 10.9 08/30/2006 09:00:00 9.5 1.1 11.5 4.6 9.7 1.2 11.8 4.9 8.9 1.2 11.1 5.3 95 5 98 165 11.1 0 11.4 10.6 08/30/2006 09:10:00 9.7 1 11.8 5.3 9.9 1 11.8 5.7 9.2 1 11.5 5.3 94 6 102 165 11.1 0 11.4 10.6 08/30/2006 09:20:00 9.5 1 11.8 6.1 9.7 1 11.8 6.5 9.1 1 11.1 6.1 94 6 95 165 11.1 0 11.4 10.6 08/30/2006 09:30:00 8.9 0.9 10.7 6.1 9.1 0.9 11.1 6.5 8.3 1 10.3 5.7 95 6 92 165 11.1 0 11.4 10.9 08/30/2006 09:40:00 8.6 0.9 10.3 5.7 8.9 0.9 11.1 6.1 8.2 1 10.3 5.3 93 5 90 165 11.1 0 11.1 10.6 08/30/2006 09:50:00 8.6 0.8 10.3 5.7 8.9 0.9 10.7 5.7 8.2 0.8 9.9 5.7 92 5 98 165 11.1 0 11.4 10.9 08/30/2006 10:00:00 8.6 0.9 10.3 5.7 8.8 1 10.7 5.3 8.1 1 10.3 5.3 93 6 97 165 11.1 0 11.4 10.6 08/30/2006 10:10:00 8.5 0.9 10.3 5.3 8.7 0.9 10.7 5.7 8 1 10.3 4.9 94 6 99 165 11.1 0 11.4 10.9 08/30/2006 10:20:00 8.7 0.7 9.9 6.5 8.9 0.7 10.3 6.5 8.1 0.9 9.9 5.7 92 5 98 165 11.1 0 11.4 10.9 08/30/2006 10:30:00 8.8 0.7 9.9 6.5 9 0.8 10.3 6.1 8.3 0.8 10.3 5.7 91 5 92 165 11.2 0 11.7 11.1 08/30/2006 10:40:00 8.9 0.6 9.9 6.5 9.1 0.6 10.3 6.8 8.4 0.8 9.9 6.1 92 5 91 165 11.2 0 11.4 10.9 08/30/2006 10:50:00 8.9 0.5 10.3 7.2 9.1 0.6 10.3 6.8 8.4 0.7 9.9 5.3 91 4 99 165 11.1 0 11.4 11.1 08/30/2006 11:00:00 8.6 0.6 9.9 6.8 8.8 0.6 9.9 6.8 8.1 0.8 9.9 6.1 91 3 91 165 11.1 0 11.4 11.1 08/30/2006 11:10:00 8.2 0.6 9.1 5.7 8.5 0.6 9.5 5.3 7.9 0.7 9.5 5.3 93 5 96 165 11.2 0 11.4 11.1 08/30/2006 11:20:00 7.9 0.6 9.1 5.7 8.1 0.7 9.5 5.7 7.2 0.8 9.1 5.3 97 5 105 165 11.2 0 11.4 10.9 08/30/2006 11:30:00 7.7 0.5 8.8 5.7 7.9 0.5 9.1 5.7 7.1 0.8 8.8 4.2 99 4 96 165 11.3 0.1 11.4 10.9 08/30/2006 11:40:00 7 0.6 8.4 4.9 7.2 0.6 8.4 5.3 6.6 0.7 8.4 4.6 103 5 105 165 11.3 0.2 11.7 10.9 08/30/2006 11:50:00 6.7 0.5 7.6 5.3 6.9 0.4 8 5.7 6.6 0.5 7.6 4.9 109 4 112 165 11.1 0.3 11.7 10.9 08/30/2006 12:00:00 5.7 0.5 6.8 4.2 5.9 0.5 7.2 4.2 5.6 0.6 6.8 4.2 112 4 112 165 11.3 0.2 11.7 10.9 08/30/2006 12:10:00 5 0.5 6.5 3 5.2 0.5 6.5 3.4 5 0.6 6.8 3.4 112 5 121 165 11.4 0.1 11.7 11.1 08/30/2006 12:20:00 4.4 0.4 5.3 3.4 4.6 0.4 5.7 3 4.5 0.5 5.3 3 107 5 114 165 11.5 0.2 11.9 11.1 08/30/2006 12:30:00 4 0.5 4.9 2.6 4.1 0.5 4.9 2.6 4.1 0.4 5.3 3 106 6 112 165 11.6 0.2 11.9 11.1 08/30/2006 12:40:00 4 0.4 4.9 3 4.1 0.4 5.3 3 4.1 0.5 4.9 2.6 105 5 105 165 11.6 0.2 12.2 11.1 08/30/2006 12:50:00 3.3 0.5 4.2 1.9 3.4 0.5 4.6 1.5 3.4 0.5 4.6 1.9 105 5 109 165 11.6 0.2 11.9 11.1 08/30/2006 13:00:00 2.3 0.4 3.4 1.1 2.3 0.5 3.4 1.1 2.6 0.4 3.8 1.5 100 6 105 165 11.7 0.2 11.9 11.4 08/30/2006 13:10:00 1.9 0.3 2.6 1.1 1.9 0.4 2.6 0.7 2.2 0.4 3 1.1 93 7 94 165 11.7 0.2 11.9 11.4 08/30/2006 13:20:00 1.6 0.4 2.6 0.4 1.6 0.5 2.6 0.4 2 0.4 2.6 1.1 89 10 92 165 11.9 0.1 12.2 11.7 08/30/2006 13:30:00 1.1 0.5 2.3 0.4 1 0.6 2.6 0.4 1.5 0.4 2.6 0.4 88 11 83 165 11.9 0.1 12.5 11.7 08/30/2006 13:40:00 0.9 0.3 1.5 0.4 0.5 0.2 1.5 0.4 1.2 0.3 2.3 0.7 83 6 89 165 11.9 0.1 12.2 11.7 08/30/2006 13:50:00 1 0.4 1.9 0.4 0.6 0.3 1.9 0.4 1.4 0.4 2.3 0.4 68 21 43 165 11.8 0 12.2 11.4 08/30/2006 14:00:00 1.4 0.4 2.3 0.4 1.1 0.5 2.3 0.4 1.8 0.5 2.6 0.4 43 8 43 165 11.7 0.1 11.9 11.4 08/30/2006 14:10:00 1.5 0.3 2.3 0.7 1.3 0.4 1.9 0.4 2.1 0.2 2.6 1.5 37 6 39 165 11.7 0.2 11.9 11.1 08/30/2006 14:20:00 1.3 0.3 1.9 0.7 0.9 0.4 1.9 0.4 2 0.3 2.6 1.1 17 8 25 165 11.6 0.2 11.9 11.4 08/30/2006 14:30:00 1.7 0.4 2.6 0.7 1.2 0.6 2.3 0.4 2.3 0.3 3 1.5 15 6 18 165 11.7 0.2 12.2 11.4 08/30/2006 14:40:00 2.1 0.2 2.6 1.5 1.5 0.5 2.6 0.4 2.6 0.3 3 1.9 13 5 10 165 11.7 0.2 12.2 11.4 08/30/2006 14:50:00 2.5 0.3 3.4 1.9 2.3 0.5 3.4 0.7 3.1 0.3 3.8 2.3 18 5 21 165 11.7 0.2 11.9 11.4 08/30/2006 15:00:00 2.7 0.2 3.4 2.3 2.6 0.3 3 1.9 3.3 0.2 3.8 2.6 23 3 27 165 11.6 0.2 11.9 11.1 08/30/2006 15:10:00 2.3 0.4 3.4 1.5 2 0.5 3 0.4 2.9 0.4 3.8 1.9 23 8 23 165 11.7 0.2 11.9 11.4 08/30/2006 15:20:00 1.7 0.3 2.6 0.7 1.5 0.5 2.6 0.4 2.3 0.3 3 1.5 20 6 22 165 11.7 0.2 12.2 11.4 08/30/2006 15:30:00 1.7 0.4 2.3 0.7 1 0.5 2.3 0.4 2.1 0.4 2.6 0.7 356 17 23 165 11.9 0.1 12.2 11.7 08/30/2006 15:40:00 1.7 0.2 2.3 1.1 0.8 0.4 1.9 0.4 2.3 0.2 2.6 1.9 9 3 10 165 12.1 0 12.2 11.7 08/30/2006 15:50:00 1.3 0.2 1.9 0.7 0.5 0.3 1.5 0.4 2 0.2 2.6 1.5 11 1 12 165 12.1 0.1 12.5 11.9 08/30/2006 16:00:00 1.1 0.2 1.5 0.4 0.5 0.2 1.5 0.4 1.6 0.2 2.3 1.1 351 9 360 165 12.1 0.1 12.5 11.9 08/30/2006 16:10:00 1.4 0.3 1.9 0.7 1 0.4 1.9 0.4 1.9 0.2 2.3 1.1 343 6 336 165 12.2 0 12.5 11.9 08/30/2006 16:20:00 1.3 0.3 2.3 0.4 1 0.4 2.3 0.4 1.9 0.3 2.6 1.1 336 7 338 165 12.2 0 12.5 11.9 08/30/2006 16:30:00 1.3 0.4 2.6 0.4 0.9 0.5 2.3 0.4 1.9 0.3 2.6 1.1 334 6 349 165 12.3 0 12.7 11.9 08/30/2006 16:40:00 1 0.4 2.3 0.4 0.6 0.4 1.9 0.4 1.6 0.4 2.6 0.7 332 11 354 165 12.5 0.1 12.7 11.9 08/30/2006 16:50:00 1.4 0.3 2.3 0.4 0.7 0.4 1.9 0.4 2 0.3 2.6 1.5 352 7 346 165 12.8 0.1 13 12.2 08/30/2006 17:00:00 2 0.4 3 0.7 1.4 0.6 3 0.4 2.2 0.4 3 1.1 351 8 344 165 12.9 0.1 13 12.5 08/30/2006 17:10:00 1.9 0.4 2.6 1.1 1.1 0.5 2.3 0.4 2.3 0.4 3 1.5 3 10 10 165 12.7 0 13 12.5 08/30/2006 17:20:00 2.9 0.5 4.2 1.1 1.6 0.6 3.4 0.4 3.1 0.4 4.2 1.9 2 6 9 165 12.8 0.1 13 12.5 08/30/2006 17:30:00 2.9 0.7 4.9 1.5 2.3 0.9 4.6 0.4 3.1 0.5 4.6 1.9 352 7 346 165 13.1 0 13.3 12.7 08/30/2006 17:40:00 4 0.7 5.7 2.3 3.2 0.9 5.7 1.1 3.8 0.7 5.3 2.3 353 9 342 165 12.7 0.2 13 12.2 08/30/2006 17:50:00 3.8 0.8 5.7 1.9 3.2 1 5.7 1.1 3.7 0.7 5.7 1.9 358 11 356 165 12.2 0 12.5 11.7 08/30/2006 18:00:00 5.2 0.7 7.2 3.8 4.8 1.1 7.2 1.9 4.8 0.8 6.8 2.6 347 9 350 165 12.1 0 12.2 11.7 08/30/2006 18:10:00 5.9 0.8 8 3 4.7 1.1 8.4 2.6 5.6 0.8 7.2 3 353 7 346 165 11.9 0 12.2 11.4 08/30/2006 18:20:00 6.4 0.7 8.8 4.6 5.5 1.3 8.8 2.3 6.2 0.7 8 4.2 350 9 343 165 12.1 0 12.5 11.7 08/30/2006 18:30:00 5.1 1.2 7.6 2.3 4.6 1.2 7.6 1.9 4.6 1.3 7.2 1.1 346 9 359 165 12.1 0 12.5 11.9 08/30/2006 18:40:00 2.6 0.8 4.6 1.1 2.1 0.7 4.6 0.7 2.5 0.7 4.6 0.4 13 18 354 165 12 0 12.2 11.9 08/30/2006 18:50:00 0.5 0.3 2.3 0.4 0.4 0.2 1.9 0.4 0.7 0.5 2.6 0.4 210 94 34 165 12 0 12.2 11.9 08/30/2006 19:00:00 0.8 0.6 2.6 0.4 0.7 0.6 2.6 0.4 1.1 0.7 3 0.4 215 17 235 165 11.9 0.1 12.2 11.7 08/30/2006 19:10:00 0.8 0.6 2.6 0.4 0.6 0.5 2.3 0.4 1.2 0.7 3 0.4 299 39 347 165 11.8 0 11.9 11.7 08/30/2006 19:20:00 2.9 0.6 4.6 1.9 2.2 0.9 4.6 0.4 3 0.5 4.6 1.9 352 11 334 165 11.8 0 11.9 11.7 08/30/2006 19:30:00 1.5 1 4.2 0.4 1.2 0.9 3.4 0.4 1.7 1.1 4.6 0.4 348 15 14 165 11.7 0.1 11.9 11.7 08/30/2006 19:40:00 1.5 0.9 3.4 0.4 1.4 0.9 3 0.4 1.8 1 3.4 0.4 320 11 322 165 11.7 0 11.9 11.4 08/30/2006 19:50:00 2.3 0.4 3.8 1.5 2.2 0.4 3.8 1.1 2.6 0.3 3.8 1.9 322 9 334 165 11.6 0.1 11.9 11.4 08/30/2006 20:00:00 2.6 0.6 4.2 1.5 2.6 0.6 3.8 1.5 2.6 0.6 4.2 1.1 314 14 318 165 11.5 0.1 11.7 11.1 08/30/2006 20:10:00 3.1 0.6 4.6 1.9 2.9 0.6 4.2 1.5 3.2 0.5 4.6 1.9 323 9 316 165 11.5 0 11.7 11.1 08/30/2006 20:20:00 3.1 0.6 4.6 1.1 2.9 0.6 4.2 0.4 3.1 0.4 4.2 1.9 318 11 317 165 11.5 0 11.7 11.1 08/30/2006 20:30:00 3.6 0.7 5.3 2.3 3.4 0.7 5.3 1.9 3.5 0.6 5.3 2.3 316 11 318 165 11.5 0.1 11.7 11.1 08/30/2006 20:40:00 3.3 0.9 5.3 0.7 3.1 1 5.7 0.4 3 0.7 4.6 0.7 310 12 305 165 11.4 0.1 11.9 11.1 08/30/2006 20:50:00 3.4 0.6 4.9 2.3 3.3 0.6 4.6 1.9 3.3 0.6 4.9 1.9 314 8 313 165 11.4 0.1 11.7 11.1 08/30/2006 21:00:00 2.5 0.6 4.2 0.7 2.3 0.6 4.2 0.4 2.6 0.6 4.6 1.5 327 14 341 165 11.3 0.1 11.7 10.9 08/30/2006 21:10:00 2 0.5 3.8 0.4 1.6 0.6 3.4 0.4 2.2 0.5 3.4 0.7 320 15 310 165 11.3 0.1 11.7 10.9 08/30/2006 21:20:00 2.6 0.6 4.6 1.1 2.4 0.6 4.2 0.7 2.6 0.5 3.8 1.5 314 17 348 165 11.3 0.1 11.7 10.9 08/30/2006 21:30:00 2.9 0.6 4.2 1.1 2.7 0.7 4.2 0.4 2.8 0.6 4.2 1.1 312 10 308 165 11.3 0.2 11.9 10.9 08/30/2006 21:40:00 3.5 1 6.5 1.9 3.3 1 6.5 1.1 3.4 0.9 5.7 1.5 321 16 332 165 11.1 0.3 11.9 10.9 08/30/2006 21:50:00 4.4 1.1 7.2 1.5 4.1 1.1 7.2 1.1 4.4 1 7.6 2.3 337 10 338 165 11.1 0.3 11.7 10.9 08/30/2006 22:00:00 4.5 1.1 7.6 2.6 4.2 1.1 8 1.5 4.5 1.1 8 2.6 338 12 346 165 11.1 0.3 11.7 10.9 08/30/2006 22:10:00 4.3 1 7.6 1.9 4 1.1 7.6 1.5 4.1 1 6.8 2.3 335 15 349 165 11.1 0.3 11.4 10.9 08/30/2006 22:20:00 4.8 1.3 8 1.5 4.5 1.3 8.8 0.7 4.7 1.2 8 1.9 338 12 347 165 11.2 0.2 11.4 10.6 08/30/2006 22:30:00 4.7 0.8 6.5 2.3 4.4 1 6.5 2.3 4.8 1 7.2 1.9 337 15 349 165 11.2 0.1 11.7 10.6 08/30/2006 22:40:00 4 0.7 5.7 1.9 3.9 0.7 5.7 1.9 4 0.7 5.7 2.6 325 10 340 165 11.2 0 11.4 10.6 08/30/2006 22:50:00 4.4 0.9 6.5 1.9 4.3 0.9 6.5 1.9 4.3 0.9 6.5 2.6 315 12 312 165 11.1 0 11.1 10.6 08/30/2006 23:00:00 6.3 0.9 8.8 3.4 6.2 1 8.8 3.4 6.2 1 8.8 3.8 335 10 353 165 11.1 0 11.1 10.9 08/30/2006 23:10:00 5.7 0.7 7.6 3.4 5.6 0.7 7.6 3.8 5.7 0.8 8 3.4 328 9 343 165 11 0 11.1 10.9 08/30/2006 23:20:00 5.4 1 8 2.6 5.2 1 8 2.6 5.1 0.9 7.6 2.6 326 16 322 165 11 0 11.1 10.9 08/30/2006 23:30:00 5.4 1.2 8.8 3 5.3 1.2 8.8 2.6 5.1 1.2 8 2.6 323 15 336 165 10.9 0 11.4 10.9 08/30/2006 23:40:00 4.6 1.4 7.6 1.5 4.4 1.5 8 0.4 4.6 1.2 7.6 1.9 334 11 334 165 10.9 0 11.1 10.9 08/30/2006 23:50:00 4.7 0.9 6.8 2.6 4.2 1.2 6.5 1.5 4.6 0.8 6.5 2.6 340 15 354 165 10.9 0 11.1 10.9 08/31/2006 00:00:00 4.8 0.6 6.8 3.4 3.4 1 6.5 1.5 4.6 0.6 6.1 2.3 358 8 351 165 10.8 0 11.1 10.3 08/31/2006 00:10:00 5.7 0.7 8.4 4.2 3.7 1 6.8 1.9 5.6 0.7 8.4 3.8 360 6 5 165 10.8 0 11.1 10.6 08/31/2006 00:20:00 8.6 1.2 11.1 5.7 7.2 1.8 11.1 3 8.3 1.3 11.1 5.3 11 10 20 165 10.7 0 10.9 10.6 08/31/2006 00:30:00 8.4 0.8 10.3 6.5 6.9 1.5 9.9 3.8 8.4 1 10.7 6.1 11 9 22 165 10.7 0.1 10.9 10.3 08/31/2006 00:40:00 8.4 0.7 9.9 6.8 6.9 1.3 9.9 4.2 8.4 0.7 9.9 6.8 11 8 15 165 10.6 0.1 10.9 10.3 08/31/2006 00:50:00 8.3 1.1 11.8 5.7 6.2 1.1 8.8 3.4 8 1.1 11.1 5.7 2 8 1 165 10.4 0 10.9 10.3 08/31/2006 01:00:00 7.4 0.9 10.7 5.3 5.7 1.2 9.9 3.4 7.1 1 10.7 4.6 360 8 16 165 10.4 0 10.6 10.1 08/31/2006 01:10:00 8.4 1.1 12.2 6.1 6.2 1 8.8 3.8 8.2 1 11.1 6.1 4 7 2 165 10.4 0 10.9 10.1 08/31/2006 01:20:00 9.7 1.3 13.3 6.5 7.9 1.7 12.2 3.8 9.5 1.3 13.3 6.1 9 10 8 165 10.3 0 10.6 9.8 08/31/2006 01:30:00 9.3 0.8 12.2 7.2 7.1 1.1 9.5 4.2 9 0.9 12.2 6.1 8 7 5 165 10.1 0.1 10.6 9.8 08/31/2006 01:40:00 9.8 1 12.2 6.8 7.7 1.4 12.6 4.6 9.3 1.1 13 6.5 1 9 347 165 10.1 0.1 10.6 9.8 08/31/2006 01:50:00 10 1.5 13.7 6.8 7.7 1.7 13.3 4.2 9.5 1.4 13.3 6.5 359 7 359 165 10.1 0 10.3 9.6 08/31/2006 02:00:00 12.1 1.5 16.1 8.4 10.1 1.8 15.6 5.3 11.7 1.7 15.3 8 354 8 354 165 10 0 10.3 9.6 08/31/2006 02:10:00 12.7 1 15.6 9.5 10.5 2.1 15.3 6.5 12.3 1.2 15.6 9.1 354 8 352 165 9.8 0 10.1 9.3 08/31/2006 02:20:00 12.1 1.6 16.8 8.4 10.4 2.1 15.6 6.5 11.6 1.5 17.6 7.6 352 9 353 165 9.8 0 9.8 9.3 08/31/2006 02:30:00 12.9 2 17.6 9.1 10.3 2.1 16.4 6.5 12.6 2 19.1 8.8 355 8 344 165 9.7 0.1 9.8 9 08/31/2006 02:40:00 12.6 1.5 17.2 8.8 10.8 1.8 16.4 6.8 12.2 1.7 16.8 8.4 353 9 360 165 9.7 0.1 10.1 9 08/31/2006 02:50:00 11.2 1.2 16.1 8.8 9.2 1.7 14.1 5.7 11.1 1.3 15.3 8.4 356 9 360 165 9.7 0.1 9.8 9.3 08/31/2006 03:00:00 10.4 1.3 13.3 6.8 9 1.8 13.7 4.9 10.3 1.3 13.7 6.5 352 8 333 165 9.7 0.1 9.8 9 08/31/2006 03:10:00 11.4 1.4 16.4 8.8 8.9 1.7 13 5.3 11.3 1.5 16.1 7.6 357 7 356 165 9.7 0.1 9.8 9 08/31/2006 03:20:00 11.3 1.7 17.2 7.2 10.1 2.3 17.6 5.3 11.1 1.8 17.2 6.5 352 9 348 165 9.8 0 9.8 9 08/31/2006 03:30:00 7.9 1.5 12.6 4.9 7.4 1.7 12.6 3.4 8 1.7 12.6 4.2 345 13 356 165 9.6 0.2 10.3 9 08/31/2006 03:40:00 7.6 0.9 11.5 5.7 7.5 1.1 11.1 4.6 7.5 0.9 9.9 5.3 339 12 330 165 9.6 0.2 9.8 9 08/31/2006 03:50:00 7.8 1.5 11.8 4.2 7.5 1.7 11.5 3.4 7.6 1.2 11.5 4.6 339 11 327 165 9.5 0.2 9.8 9 08/31/2006 04:00:00 8.7 1.2 11.5 5.7 8.6 1.2 11.1 4.9 8 1.2 11.5 3.8 329 11 324 165 9.6 0.2 9.6 9 08/31/2006 04:10:00 7.1 1.2 10.3 5.3 6.5 1.5 10.7 3 7 1.2 9.9 4.6 349 8 359 165 9.6 0.2 9.6 9 08/31/2006 04:20:00 8.2 1 10.7 5.3 8.2 1 10.7 4.9 7.6 1.3 10.7 4.2 326 13 326 165 9.6 0.1 9.6 9 08/31/2006 04:30:00 8.7 1.3 12.6 5.7 8.7 1.3 12.6 5.7 7.9 1.3 11.8 4.9 326 12 330 165 9.6 0 9.6 9.3 08/31/2006 04:40:00 8.3 1.7 13.3 5.3 8.3 1.7 13.3 5.3 8 1.7 13.3 4.6 332 10 329 165 9.5 0.1 9.8 9 08/31/2006 04:50:00 8.6 1.1 11.5 5.7 8.6 1 11.5 5.7 8.3 1 11.1 5.7 332 11 331 165 9.5 0.1 9.8 9 08/31/2006 05:00:00 9.6 1.5 13.7 5.3 9.5 1.7 13.7 4.2 9.4 1.7 13.7 5.3 332 12 329 165 9.6 0.1 9.6 9 08/31/2006 05:10:00 9.3 1.7 14.1 5.3 9.2 1.7 14.1 4.9 9.1 1.7 13 4.9 336 9 323 165 9.6 0 9.8 9.3 08/31/2006 05:20:00 8.6 1.2 13 4.9 8.6 1.2 13 5.3 8.5 1.2 13 5.7 330 10 338 165 9.6 0 9.6 9 08/31/2006 05:30:00 9.7 1.3 13 6.5 9.6 1.3 13.7 6.1 9.6 1.3 13.3 6.1 330 11 332 165 9.6 0 9.6 9.3 08/31/2006 05:40:00 9.6 1.7 13.7 6.5 9.4 1.7 13.7 5.3 9.4 1.7 14.1 6.5 329 12 331 165 9.5 0.1 9.8 9.3 08/31/2006 05:50:00 10.4 1.9 16.4 6.5 10.3 2 16.8 6.5 10.2 1.9 15.6 6.5 331 10 341 165 9.5 0.1 9.6 9.3 08/31/2006 06:00:00 11.2 1.7 16.1 7.6 11 2.1 16.8 5.3 10.9 1.8 16.4 6.8 337 13 344 165 9.6 0 9.8 9.6 08/31/2006 06:10:00 11.6 1.9 17.2 5.7 11.3 2.1 16.8 4.2 11.3 1.9 18.3 5.7 341 12 358 165 9.6 0 9.8 9.6 08/31/2006 06:20:00 12.3 1.5 16.1 8.4 11.9 1.7 16.4 8 12 1.7 16.8 7.2 336 12 349 165 9.6 0 9.8 9.6 08/31/2006 06:30:00 11.5 1.8 16.8 6.1 11.4 1.8 16.8 5.7 11.3 1.8 15.6 7.2 337 9 337 165 9.7 0 9.8 9.6 08/31/2006 06:40:00 11.8 1.7 18.7 8 11.6 1.7 18.7 7.2 11.7 2 17.6 7.6 335 12 356 165 9.7 0 10.3 9.6 08/31/2006 06:50:00 13.1 1.8 18.7 6.5 12.7 2 18.3 6.8 12.5 1.9 18.3 5.7 335 12 336 165 9.7 0 9.8 9.6 08/31/2006 07:00:00 12.4 1.6 16.1 6.8 12.1 1.8 16.1 7.2 12 1.8 16.1 6.8 339 10 337 165 9.8 0 10.1 9.6 08/31/2006 07:10:00 14.1 1.6 18.3 9.1 13.6 2.2 17.9 7.2 13.9 1.6 17.6 8.4 337 10 332 165 10 0 10.3 9.3 08/31/2006 07:20:00 11.7 2 16.8 7.2 11.6 2.1 17.2 6.8 11.4 2.1 18.7 6.5 333 14 341 165 10.1 0.1 10.3 9.6 08/31/2006 07:30:00 12 1.7 16.4 8.8 11.8 1.7 16.8 8.4 11.5 1.9 16.8 6.8 329 15 340 165 10.2 0 10.3 9.6 08/31/2006 07:40:00 10.7 1.4 13.7 7.6 10.6 1.3 13.7 7.2 9.9 1.7 13.3 6.1 313 11 321 165 10 0 10.3 9.6 08/31/2006 07:50:00 10.8 1.5 16.8 7.6 10.7 1.4 17.2 7.2 10.1 1.5 15.6 6.1 320 12 313 165 10 0 10.3 9.3 08/31/2006 08:00:00 10.6 1.1 13.7 7.6 10.5 1.2 13.3 7.6 10.2 1.2 13.3 7.2 325 13 339 165 10.1 0.2 10.3 9.3 08/31/2006 08:10:00 10.6 1.5 13.7 6.1 10.5 1.4 13.7 6.8 9.7 1.5 13.3 5.7 319 13 344 165 10.1 0.2 10.6 9.3 08/31/2006 08:20:00 10.3 1.3 13.7 6.5 10.2 1.2 13.7 6.8 9.7 1.3 13 6.8 317 12 310 165 10 0.2 10.3 9.3 08/31/2006 08:30:00 11.1 1.4 14.5 7.2 11 1.3 14.1 7.2 9.7 1.5 13.3 5.3 310 11 297 165 10 0.2 10.3 9.3 08/31/2006 08:40:00 12.1 1.3 16.4 8 12 1.3 16.4 8 10 1.5 14.9 5.3 308 7 312 165 9.8 0.2 10.3 9.3 08/31/2006 08:50:00 11.8 0.9 14.9 8.8 11.6 0.9 14.9 8.8 10.9 1.4 14.9 7.6 313 6 318 165 9.8 0.2 10.1 9 08/31/2006 09:00:00 12.1 1.2 16.4 9.9 12 1.2 16.8 9.9 11.2 1.3 15.3 8.8 313 5 313 165 9.8 0.2 10.3 9 08/31/2006 09:10:00 12.9 1 15.6 9.9 12.8 1 15.3 9.9 11.3 1.2 14.5 8 310 4 310 165 9.9 0.1 10.3 9.3 08/31/2006 09:20:00 13.8 0.9 16.1 10.3 13.6 0.9 16.1 10.7 11.9 1.3 15.6 8.8 309 4 305 165 10 0.1 10.3 9.3 08/31/2006 09:30:00 14.1 0.9 16.1 11.1 14 0.9 16.1 10.7 11.5 1.2 14.9 8.4 307 4 306 165 10.1 0.2 10.3 9.6 08/31/2006 09:40:00 14.3 1 16.8 11.8 14.3 1 16.8 11.5 12.2 1.5 16.4 8.8 309 5 304 165 10.1 0.1 10.6 9.6 08/31/2006 09:50:00 14.2 1 16.8 11.1 14.1 1 16.4 11.1 11.9 1.2 14.9 8.8 307 5 303 165 10.2 0 10.6 9.8 08/31/2006 10:00:00 14.7 1 16.8 11.8 14.6 1.1 16.8 11.5 12.7 1.3 15.6 9.1 309 3 302 165 10.3 0 10.9 9.8 08/31/2006 10:10:00 15.1 0.9 18.3 12.6 15.1 0.9 17.9 12.6 13.5 1.2 16.1 9.5 310 4 304 165 10.3 0 10.6 9.8 08/31/2006 10:20:00 14.9 0.9 17.2 11.8 14.9 1 17.6 11.8 13.2 1.5 17.2 9.1 310 4 302 165 10.4 0 10.6 9.8 08/31/2006 10:30:00 15.6 0.9 18.3 12.6 15.5 0.9 18.3 12.2 13.9 1.2 16.4 10.7 310 4 307 165 10.5 0 10.9 10.1 08/31/2006 10:40:00 15.2 0.9 17.2 11.1 15.1 1 17.2 11.5 13.2 1.3 16.1 9.9 309 5 305 165 10.5 0.1 10.9 9.8 08/31/2006 10:50:00 14.4 0.9 16.4 11.5 14.4 0.9 16.1 11.5 12.5 1.5 16.1 8.8 309 5 313 165 10.7 0.1 10.9 10.3 08/31/2006 11:00:00 14.1 0.7 16.4 11.8 14 0.7 16.1 11.5 12.2 1.2 15.3 9.1 309 4 307 165 10.6 0 10.9 10.3 08/31/2006 11:10:00 14.2 1.1 17.2 10.7 14.1 1.1 17.2 10.3 12.4 1.5 16.8 8.4 310 4 305 165 10.7 0 11.1 10.6 08/31/2006 11:20:00 14.4 1 17.2 11.8 14.3 1.1 16.8 11.8 13 1.2 16.1 9.1 310 5 310 165 10.7 0 10.9 10.6 08/31/2006 11:30:00 13.7 0.9 15.6 11.5 13.7 1 16.1 11.1 12.8 1 14.9 9.1 312 5 310 165 10.7 0 11.1 10.6 08/31/2006 11:40:00 13 1 15.3 9.9 13 1 15.3 9.9 12.5 1.1 14.9 9.5 315 5 313 165 10.9 0 11.1 10.6 08/31/2006 11:50:00 12.9 0.9 14.5 9.9 12.8 0.9 14.5 9.9 12.1 1.1 14.9 9.1 313 6 315 165 11 0 11.1 10.6 08/31/2006 12:00:00 12.1 0.9 14.5 9.5 12 0.9 14.1 9.5 11.6 1.2 14.5 7.6 315 6 312 165 11.2 0 11.4 10.9 08/31/2006 12:10:00 10.5 0.8 12.6 8 10.4 0.8 12.6 8 10.3 1 13 7.6 321 6 332 165 11.5 0 11.7 11.1 08/31/2006 12:20:00 12.7 1.5 16.8 8.8 12.6 1.6 17.2 9.1 11.8 1.4 16.1 7.6 315 9 297 165 11.5 0 11.7 11.1 08/31/2006 12:30:00 12.8 1.4 17.2 8.8 12.6 1.4 17.2 8.4 12.1 1.5 15.6 7.6 317 9 312 165 11.6 0.2 11.9 11.1 08/31/2006 12:40:00 14.2 1.2 17.2 10.7 14.1 1.2 17.2 11.1 13.5 1.4 16.4 10.3 316 7 297 165 11.3 0.2 11.9 10.9 08/31/2006 12:50:00 14.7 1.3 17.6 9.5 14.6 1.4 17.6 9.1 13.8 1.3 17.2 10.3 314 6 311 165 10.9 0 11.1 10.6 08/31/2006 13:00:00 14 1.1 16.8 11.5 13.9 1.1 16.8 11.5 13.4 1.2 16.4 10.3 316 6 305 165 10.8 0 11.1 10.9 08/31/2006 13:10:00 13.8 0.9 15.6 11.1 13.8 1 15.6 11.1 13 1 15.6 9.5 314 6 315 165 10.8 0 11.1 10.6 08/31/2006 13:20:00 13.4 1 15.6 10.7 13.4 1 15.6 10.7 12.1 1.3 15.6 8.4 311 5 304 165 10.9 0 11.1 10.9 08/31/2006 13:30:00 11.7 1.2 15.6 9.1 11.7 1.2 15.3 9.1 11.1 1.2 14.5 6.8 314 6 312 165 11.1 0 11.4 10.9 08/31/2006 13:40:00 10.7 0.9 13.3 8.4 10.6 0.9 13.3 8 10.1 1 13 7.2 317 7 315 165 11.1 0 11.4 10.9 08/31/2006 13:50:00 12.1 1.2 14.9 9.1 12 1.2 14.5 9.1 11.1 1.5 14.5 7.2 312 7 310 165 11.2 0 11.4 10.9 08/31/2006 14:00:00 11.8 1.2 14.9 8.4 11.7 1.2 14.9 8.8 11.2 1.1 14.9 8.8 315 6 313 165 11.1 0 11.1 10.9 08/31/2006 14:10:00 11.4 1.1 14.9 8.8 11.3 1.1 14.9 8.4 10.8 1.2 13.7 7.2 315 6 309 165 11 0 11.1 10.9 08/31/2006 14:20:00 12.8 1 15.3 9.9 12.7 1 15.3 9.5 12.4 1.3 15.3 8.4 315 5 314 165 10.9 0 11.1 10.9 08/31/2006 14:30:00 11.5 1.3 14.9 8 11.4 1.3 14.9 7.6 11.1 1.3 14.5 7.6 317 6 316 165 11 0 11.4 10.9 08/31/2006 14:40:00 9.9 1.1 13.3 7.2 9.9 1.1 13 7.2 9.4 1.2 13 6.1 315 7 309 165 11.1 0 11.4 10.9 08/31/2006 14:50:00 9.4 0.8 11.8 6.8 9.3 0.8 11.8 6.8 8.8 0.9 10.7 6.1 314 7 304 165 11.1 0 11.4 10.9 08/31/2006 15:00:00 10.9 1 13.3 7.6 10.8 1 13.3 7.6 9.5 1.1 12.2 6.1 310 5 315 165 11.2 0 11.4 11.1 08/31/2006 15:10:00 10.6 1.1 13.3 8 10.5 1.1 13.3 7.6 9.5 1.2 12.6 6.5 311 8 302 165 11.2 0 11.7 11.1 08/31/2006 15:20:00 11.4 1.3 14.1 8 11.3 1.3 14.1 8 10.5 1.2 13 7.6 313 8 309 165 11.1 0 11.4 11.1 08/31/2006 15:30:00 11.6 1.2 15.6 8.8 11.5 1.2 15.6 8.4 10.3 1.2 13.3 7.2 310 6 313 165 11.1 0 11.4 10.9 08/31/2006 15:40:00 12.1 1.1 15.3 8.4 12 1.2 14.9 9.1 10.7 1.3 13.7 7.6 310 6 310 165 11 0 11.1 10.9 08/31/2006 15:50:00 12.7 1.1 16.4 9.5 12.5 1.1 16.8 9.5 11.8 1.4 16.4 8 313 6 313 165 10.9 0 11.1 10.9 08/31/2006 16:00:00 13.6 1.1 16.8 10.7 13.5 1.1 16.4 10.3 12.8 1.1 16.8 9.9 314 5 313 165 11 0 11.1 10.9 08/31/2006 16:10:00 14.3 1 17.6 11.8 14.3 1 17.2 11.8 13.6 1.2 17.6 9.5 314 5 309 165 11 0 11.1 10.9 08/31/2006 16:20:00 14 0.9 16.8 11.8 13.9 0.9 16.4 11.5 13.2 1 15.6 11.1 314 5 312 165 11 0 11.1 10.9 08/31/2006 16:30:00 13.1 1 15.3 10.3 12.9 1 15.3 10.3 12.5 1 14.9 9.5 316 6 311 165 11 0 11.1 10.9 08/31/2006 16:40:00 13.1 1 16.1 9.9 13 1 16.1 9.9 13.1 0.9 15.6 10.3 321 5 317 165 11.1 0 11.4 10.9 08/31/2006 16:50:00 12.2 0.8 14.5 9.5 12 0.8 14.5 9.1 12 0.9 14.1 9.1 321 7 310 165 11.1 0 11.4 10.9 08/31/2006 17:00:00 10.5 0.7 12.2 8.8 10.4 0.8 12.2 8.4 10.4 0.8 12.2 7.6 319 6 322 165 11.1 0 11.4 10.9 08/31/2006 17:10:00 10.3 0.9 12.2 7.2 10.2 0.9 12.2 7.2 10 0.9 12.2 7.6 318 6 312 165 11.1 0 11.4 10.9 08/31/2006 17:20:00 10.1 0.9 13 8 10 0.8 12.6 8 10 0.8 12.6 7.6 318 6 315 165 11.1 0 11.4 10.9 08/31/2006 17:30:00 10.8 1 13 8.4 10.7 1 13 8.4 10.6 1 13 7.2 317 5 309 165 11.1 0 11.4 10.9 08/31/2006 17:40:00 9.9 0.7 11.8 8 9.8 0.7 11.8 8 9.6 0.8 11.8 6.5 317 6 310 165 11.1 0 11.4 10.9 08/31/2006 17:50:00 9.6 0.6 11.8 8 9.6 0.6 11.5 7.6 9.4 0.6 11.1 7.2 316 5 305 165 11.1 0 11.4 10.9 08/31/2006 18:00:00 9.3 0.8 11.5 6.5 9.3 0.8 11.1 6.8 9.2 0.7 11.1 7.2 320 8 313 165 11.2 0 11.4 10.9 08/31/2006 18:10:00 10 0.7 11.8 8 10 0.7 11.8 8 9.7 0.7 11.5 7.6 315 4 313 165 11.2 0.1 11.4 10.9 08/31/2006 18:20:00 10.1 1 13 8 10.1 1 13.3 8 9.8 1.1 13 7.2 313 4 312 165 11.2 0 11.4 10.9 08/31/2006 18:30:00 10.1 0.7 12.2 8 10.1 0.7 12.2 8 9.8 0.7 11.5 7.6 313 5 308 165 11.2 0 11.4 10.9 08/31/2006 18:40:00 9.9 0.8 11.8 8.4 9.8 0.8 12.2 8 9.6 0.8 11.8 7.6 314 4 308 165 11.2 0 11.4 10.9 08/31/2006 18:50:00 9.8 0.7 11.8 8 9.8 0.7 11.8 7.6 9.2 0.8 11.5 6.8 314 6 310 165 11.3 0 11.4 10.9 08/31/2006 19:00:00 9.9 0.7 11.5 7.6 9.9 0.7 11.5 7.6 9.6 0.8 11.8 7.2 316 5 307 165 11.2 0.1 11.7 10.9 08/31/2006 19:10:00 9.1 0.8 11.1 6.8 9 0.8 11.1 6.5 9 0.7 10.7 7.2 320 5 318 165 11 0 11.7 10.6 08/31/2006 19:20:00 9.1 0.6 11.5 7.6 9 0.6 11.1 7.6 8.9 0.6 10.7 6.8 317 4 319 165 10.9 0 11.1 10.6 08/31/2006 19:30:00 9.9 0.8 11.8 7.2 9.8 0.8 11.8 7.2 9.5 0.7 11.5 7.6 316 5 314 165 10.9 0 11.1 10.6 08/31/2006 19:40:00 10.6 0.8 12.6 7.6 10.4 0.8 12.6 8 10.3 1 12.2 7.6 318 6 311 165 10.9 0 11.1 10.6 08/31/2006 19:50:00 10.7 0.8 13 8.8 10.6 0.8 13 8.8 10.1 0.9 12.6 8 316 6 312 165 11 0 11.1 10.6 08/31/2006 20:00:00 10.9 0.9 13 8 10.8 0.8 13 8 10.1 1 12.6 6.8 313 7 307 165 11.1 0 11.4 10.9 08/31/2006 20:10:00 11.9 1.1 14.9 9.1 11.7 1.1 14.9 9.1 11.2 1 14.1 8.8 316 5 316 165 11.2 0 11.4 10.9 08/31/2006 20:20:00 13.4 1.2 17.2 10.3 13.3 1.3 16.8 10.3 12.7 1.3 15.6 9.5 315 6 310 165 11.3 0 11.7 10.9 08/31/2006 20:30:00 14.1 1.2 16.8 10.3 13.9 1.2 16.4 10.3 13.5 1.4 17.6 9.5 316 5 319 165 11.5 0 11.7 11.1 08/31/2006 20:40:00 13.9 0.8 16.1 11.8 13.8 0.9 16.4 11.8 12.8 1 15.6 9.1 312 4 305 165 11.4 0 11.7 11.1 08/31/2006 20:50:00 13.6 1.2 16.4 10.7 13.5 1.2 16.8 10.7 12.5 1.3 15.6 7.6 312 5 319 165 11.3 0 11.7 11.1 08/31/2006 21:00:00 14.1 1.1 16.8 10.7 13.9 1.1 16.4 11.1 13.1 1.2 15.6 9.1 315 5 310 165 11.5 0 11.7 11.1 08/31/2006 21:10:00 12.9 1 14.9 9.9 12.6 1 14.9 9.9 12.3 1 15.6 9.5 316 5 311 165 11.5 0 12.2 11.1 08/31/2006 21:20:00 12.5 0.9 14.9 10.3 12.3 0.9 14.9 9.9 11.4 1 14.5 8.4 314 5 312 165 11.4 0 11.7 11.1 08/31/2006 21:30:00 11.6 1.1 16.1 8.4 11.5 1 15.3 8.8 10.5 1.2 14.1 6.8 313 6 302 165 11.3 0.1 11.7 10.9 08/31/2006 21:40:00 11.4 1 14.5 8.4 11.3 1 14.5 8.4 10.4 1.1 14.1 7.2 314 5 308 165 11.3 0.1 11.7 10.9 08/31/2006 21:50:00 10.3 0.7 12.6 8.4 10.2 0.7 12.2 8.4 9.4 1 11.8 6.1 314 6 302 165 11.3 0 11.7 10.9 08/31/2006 22:00:00 10.6 1.2 14.5 6.8 10.5 1.2 14.5 7.6 9.6 1.2 14.1 6.8 313 7 304 165 11.5 0 11.7 11.1 08/31/2006 22:10:00 9.8 1 13 7.2 9.6 1 13 7.2 8.8 1.2 12.6 5.7 313 7 310 165 11.3 0.1 11.7 10.9 08/31/2006 22:20:00 9.5 1.2 13 6.8 9.4 1.1 12.6 6.8 8 1.2 11.1 4.2 308 7 300 165 11.2 0.1 11.4 10.9 08/31/2006 22:30:00 9.5 0.8 11.5 6.8 9.4 0.8 11.5 7.2 8 1 10.3 5.7 308 5 305 165 11 0 11.4 10.6 08/31/2006 22:40:00 8.3 1 12.2 5.7 8.2 1 12.2 6.1 6.9 1.2 11.8 4.6 307 7 303 165 11 0 11.4 10.6 08/31/2006 22:50:00 6.4 0.9 9.9 4.2 6.4 0.8 10.7 4.2 5.4 0.9 8 3.4 309 9 304 165 10.9 0.2 11.4 10.3 08/31/2006 23:00:00 6.6 0.8 8.8 4.6 6.6 0.7 8.4 4.6 5.3 0.8 6.8 3 305 7 301 165 10.7 0.1 10.9 10.3 08/31/2006 23:10:00 5.2 1 8 2.6 5.2 1 8.4 2.6 4.7 0.8 7.6 2.6 318 11 315 165 10.6 0.2 10.9 10.1 08/31/2006 23:20:00 3.8 0.9 6.5 1.9 3.8 0.9 7.2 2.3 3.9 0.8 6.5 2.6 331 9 340 165 10.7 0.2 11.1 9.8 08/31/2006 23:30:00 5.3 1.3 9.1 3 5.2 1.3 9.5 2.6 5.2 1.3 9.1 2.6 348 20 341 165 10.6 0.2 11.1 10.3 08/31/2006 23:40:00 7.1 1.2 10.3 4.6 7 1.3 9.9 4.2 7.2 1.1 9.5 4.6 337 12 327 165 10.6 0.2 11.1 10.1 08/31/2006 23:50:00 8.5 1.2 12.6 6.1 8.4 1.3 13 5.7 8.3 1.2 12.6 5.7 339 10 344 165 10.5 0.2 10.9 10.1 09/01/2006 00:00:00 7.7 1.2 11.1 4.6 7.5 1.1 10.7 4.6 7.3 1.3 10.7 4.6 337 12 353 165 10.5 0 10.9 9.8 09/01/2006 00:10:00 9.2 1.3 13 5.7 9.2 1.5 13.3 5.7 9 1.3 12.6 6.1 337 9 347 165 10.7 0.1 10.9 10.3 09/01/2006 00:20:00 10.2 1.3 13.7 7.6 9.7 1.7 13.7 4.9 10 1.4 14.5 5.7 340 11 349 165 10.7 0.1 11.1 10.3 09/01/2006 00:30:00 9.8 1.3 13.7 6.8 9.7 1.3 13.7 6.1 9.3 1.4 13.3 5.3 336 9 349 165 10.8 0.1 11.1 10.3 09/01/2006 00:40:00 10.4 1.6 16.1 6.5 10.3 1.6 13.7 4.9 10.5 1.7 14.9 6.5 338 10 357 165 10.8 0.1 11.1 10.3 09/01/2006 00:50:00 9.8 1.5 13 5.3 9.2 2 13 3.4 9.6 1.5 12.6 4.6 343 15 329 165 10.9 0 11.1 10.3 09/01/2006 01:00:00 8.6 1.1 11.8 5.3 8.5 1.1 11.8 4.9 8.2 1.2 11.8 4.9 322 12 310 165 10.7 0.2 11.1 10.1 09/01/2006 01:10:00 7.8 1 11.1 4.6 7.8 1.1 11.5 4.6 7.5 1 11.1 4.6 333 12 320 165 10.6 0.1 11.1 10.1 09/01/2006 01:20:00 7.1 0.9 10.7 4.9 6.9 1.1 9.9 3.8 7 1 10.3 4.6 335 13 330 165 10.7 0.1 10.9 10.1 09/01/2006 01:30:00 6.4 0.7 8.8 4.9 5.8 1.2 8.4 3 6.5 0.7 8.4 4.6 348 10 332 165 10.5 0 10.9 9.8 09/01/2006 01:40:00 6.7 1.2 9.9 3.8 6.1 1.1 9.5 3 6.8 1.2 9.5 4.2 347 10 2 165 10.5 0 10.9 9.8 09/01/2006 01:50:00 6.2 0.8 8.8 4.2 5.6 1 8.4 3.4 6 0.9 8.4 4.2 347 12 349 165 10.5 0 10.9 9.8 09/01/2006 02:00:00 6.4 0.9 9.1 4.6 5.8 1 9.1 3 6.3 1 9.5 4.6 350 8 342 165 10.5 0 10.9 9.8 09/01/2006 02:10:00 4.9 0.9 7.2 3 4.9 1 7.6 2.3 4.9 1.1 7.6 3 340 9 352 165 10.5 0.1 11.1 9.8 09/01/2006 02:20:00 6 0.7 7.6 3.8 4.6 1.1 8 2.3 5.8 0.7 8 3.8 355 8 356 165 10.3 0.1 10.6 9.8 09/01/2006 02:30:00 6.6 1.1 8.8 3.4 6.3 1.1 8.8 3.4 6.2 1.2 9.1 2.6 344 8 342 165 10.5 0.2 10.9 9.8 09/01/2006 02:40:00 5.5 0.9 7.6 3.8 5 1.3 8 2.6 5.2 0.9 8 3.4 347 9 345 165 10.5 0.2 10.9 9.8 09/01/2006 02:50:00 6.1 0.6 8 4.6 5.7 1 8.4 3 5.8 0.7 7.6 4.2 348 9 342 165 10.5 0.2 10.9 9.8 09/01/2006 03:00:00 5.2 1.3 8.8 2.6 4.5 1 7.6 2.3 4.8 1.3 8.4 3 348 9 6 165 10.5 0 10.9 9.8 09/01/2006 03:10:00 7.4 0.9 10.7 4.9 5.5 1.4 9.9 2.6 7.4 0.8 10.3 4.9 359 9 8 165 10.5 0.2 10.9 9.8 09/01/2006 03:20:00 6.5 1 9.1 4.6 5.4 1 8 2.6 6.3 1 9.1 4.2 353 9 4 165 10.5 0.2 10.9 10.1 09/01/2006 03:30:00 6.1 1 8.8 2.6 5.5 1.3 8.8 2.3 5.8 1 8 3.4 349 8 349 165 10.5 0.2 10.9 9.8 09/01/2006 03:40:00 6.5 1.1 9.5 3.4 6.3 1.2 9.5 3 6 1 8.4 2.6 343 8 344 165 10.5 0.2 10.9 9.8 09/01/2006 03:50:00 6.5 0.6 8 4.9 6.3 0.8 8 3.4 5.8 0.7 7.6 2.6 345 6 358 165 10.4 0.1 10.6 9.8 09/01/2006 04:00:00 6.6 0.8 8.8 4.2 5.9 1.3 8.8 3 6.2 0.9 8.8 3.4 350 9 350 165 10.5 0.2 10.9 9.8 09/01/2006 04:10:00 7 1 10.7 4.6 6.1 1.3 9.9 3 6.7 1 9.9 3.8 350 10 356 165 10.5 0.2 10.9 9.8 09/01/2006 04:20:00 6.1 1 8.4 3.8 5.9 1.2 8.4 2.6 5.6 1 8.4 3.8 342 8 350 165 10.5 0.2 10.9 9.8 09/01/2006 04:30:00 7.2 1.3 11.1 4.6 6 1.3 10.7 3 7 1.3 10.7 3.8 353 9 11 165 10.6 0.2 11.1 9.8 09/01/2006 04:40:00 7.5 0.8 9.5 5.3 6.4 1.3 9.5 3.4 7.2 0.9 9.5 5.3 353 8 353 165 10.7 0.1 11.1 10.1 09/01/2006 04:50:00 7.2 0.8 9.9 5.3 5.7 1.3 8.8 3 7.1 0.9 9.9 4.9 354 9 10 165 10.6 0.1 11.1 10.1 09/01/2006 05:00:00 6.3 0.9 9.9 4.2 5.7 1 9.1 3 6 1 9.1 4.2 348 9 4 165 10.7 0.1 10.9 9.8 09/01/2006 05:10:00 7.2 1.2 11.8 5.3 6.6 1.5 11.1 3.4 7 1.3 10.7 4.2 350 11 9 165 10.5 0 10.9 9.8 09/01/2006 05:20:00 7.3 1 9.9 4.6 6.3 1.2 9.5 3 7.1 1 9.5 4.2 353 11 360 165 10.5 0 10.9 9.8 09/01/2006 05:30:00 7 1.1 10.7 4.6 5.7 1.5 10.3 2.6 6.7 1.2 9.9 4.2 354 9 359 165 10.6 0 10.9 10.1 09/01/2006 05:40:00 5.9 0.9 8 3.8 5 1.1 8 2.3 5.6 1 7.6 3.4 352 8 7 165 10.6 0 10.9 9.8 09/01/2006 05:50:00 7.3 1 10.3 4.9 6.7 1.3 10.7 3 6.9 1.1 10.3 4.2 347 10 2 165 10.6 0.1 10.9 9.8 09/01/2006 06:00:00 6.5 0.8 8.8 4.6 5.9 1.2 8.4 2.6 6.2 0.8 7.6 4.2 347 8 336 165 10.6 0.1 10.9 9.8 09/01/2006 06:10:00 7.7 1 10.3 5.3 7.2 1.4 10.3 3 7.6 1.1 10.3 4.9 346 9 345 165 10.7 0.2 10.9 9.8 09/01/2006 06:20:00 5.9 0.8 8.4 3.4 5.6 1 8 2.6 6 0.8 8 3.8 342 11 302 165 10.5 0 10.9 9.8 09/01/2006 06:30:00 6.5 0.8 8.8 4.9 6.3 0.9 8.8 3.4 6.4 0.7 8.4 4.9 342 7 338 165 10.5 0.1 10.9 9.8 09/01/2006 06:40:00 5.9 1 8.8 3.8 5.7 1.1 8.8 3 5.7 0.9 8.8 4.2 340 9 342 165 10.7 0.2 10.9 9.8 09/01/2006 06:50:00 5.3 0.5 7.2 3.8 5.1 0.7 7.2 2.3 5.3 0.5 7.2 3.8 340 9 329 165 10.5 0.2 10.9 9.8 09/01/2006 07:00:00 6 1.3 9.9 3.8 5.6 1.6 9.9 2.3 5.9 1.3 10.3 3.4 343 9 346 165 10.5 0.2 10.9 9.8 09/01/2006 07:10:00 7.4 1 9.9 4.6 7 1.2 9.9 3.4 7.3 1 10.3 4.9 346 8 353 165 10.7 0.2 11.1 10.3 09/01/2006 07:20:00 7.6 0.8 10.3 5.3 6.8 1.2 10.3 3.8 7.2 0.9 10.7 4.6 351 9 347 165 10.9 0 11.1 10.6 09/01/2006 07:30:00 8.2 1.3 12.6 4.6 7.5 1.6 11.8 3.8 7.5 1.3 11.8 4.6 348 7 355 165 11.1 0.2 11.4 10.6 09/01/2006 07:40:00 7.8 1 10.3 4.6 7.4 1.2 9.9 3.4 7.2 1 9.9 3.8 346 9 352 165 11.2 0.1 11.4 10.6 09/01/2006 07:50:00 6.4 0.8 8.4 3.8 6 1 8.8 3 5.9 0.7 7.6 4.2 346 8 340 165 11.4 0.1 11.9 10.9 09/01/2006 08:00:00 6.1 1 8.4 3.8 5.3 1.2 8 2.6 5.5 1 7.6 3.4 348 10 358 165 11.8 0.1 11.9 11.4 09/01/2006 08:10:00 5.3 0.8 7.6 3 4.8 0.9 7.6 2.3 4.8 0.8 6.8 3 347 9 332 165 11.9 0 11.9 11.4 09/01/2006 08:20:00 7.3 1.1 10.7 4.9 6.6 1.2 9.1 3.8 6.9 1.3 9.9 3.8 349 13 360 165 11.8 0.1 11.9 11.4 09/01/2006 08:30:00 8.1 1 10.7 5.3 6.7 1.6 11.1 3.4 8 1 11.1 5.3 353 10 3 165 11.8 0.1 12.2 11.4 09/01/2006 08:40:00 7.6 1 11.1 4.9 7.2 1.2 11.1 3.8 7.2 1.1 10.7 4.9 343 10 333 165 12.1 0.3 12.5 11.7 09/01/2006 08:50:00 7.2 1.1 9.9 4.6 6.7 1.2 9.5 3.4 6.9 1.1 10.3 4.2 343 12 353 165 12.1 0.2 12.5 11.9 09/01/2006 09:00:00 7.1 1.1 9.9 4.6 6.2 1.3 8.8 3 6.9 1 9.9 4.2 349 12 4 165 11.7 0.2 12.2 11.4 09/01/2006 09:10:00 7.1 1.1 10.3 4.2 6.9 1.3 9.9 2.6 7 1.1 9.5 4.6 330 12 320 165 11.3 0.2 11.7 10.9 09/01/2006 09:20:00 8 1 11.5 5.3 7.6 1.1 11.5 4.9 8.1 1 11.1 5.3 339 11 357 165 11.1 0.2 11.4 10.6 09/01/2006 09:30:00 7.4 1.1 10.3 4.9 7.3 1.2 9.9 3.8 7.3 1 9.9 4.6 333 10 341 165 11.3 0.2 11.7 10.9 09/01/2006 09:40:00 7.5 0.8 9.9 4.9 6.6 1.2 9.9 4.2 7.4 0.9 9.9 5.3 346 17 18 165 11.3 0.3 11.7 10.9 09/01/2006 09:50:00 9.9 1.2 13.3 7.2 8.8 1.6 13.3 4.6 9.6 1.3 13.3 6.5 351 8 351 165 11.3 0.2 11.7 10.9 09/01/2006 10:00:00 9 1.3 11.8 5.7 8.9 1.3 11.8 5.3 8.7 1.3 11.5 5.3 340 10 340 165 11.2 0 11.4 10.9 09/01/2006 10:10:00 8.6 1.2 12.2 5.7 8 1.3 12.2 3.8 8 1.3 11.8 4.6 345 15 3 165 11.2 0 11.4 10.9 09/01/2006 10:20:00 7.8 1.1 12.6 6.1 7.7 1.2 12.6 3.8 7.5 1.1 10.7 5.3 337 12 347 165 11.3 0 11.4 10.9 09/01/2006 10:30:00 7.6 1.5 10.7 3.8 7.3 1.5 10.3 3.8 7 1.5 10.3 3 334 13 333 165 11.7 0.3 12.5 11.1 09/01/2006 10:40:00 6.8 1.2 9.9 3.8 6.8 1.2 10.3 3.4 6.1 1.3 9.5 3 328 14 347 165 12.5 0.2 13 11.9 09/01/2006 10:50:00 7.2 1 10.3 4.9 6.3 1.2 9.9 3.4 7 1.2 11.1 3.8 344 15 1 165 13.3 0.4 14.1 12.7 09/01/2006 11:00:00 7.1 1 9.5 4.2 6.2 1.2 9.1 3.4 7.1 1.1 9.5 4.6 352 13 7 165 13.8 0.2 14.1 13 09/01/2006 11:10:00 8.3 1.4 12.6 5.7 7.2 1.7 11.5 3.4 8.3 1.4 13 5.3 351 12 355 165 13.8 0 14.4 13.3 09/01/2006 11:20:00 8.1 1.4 11.5 4.6 6.8 1.7 11.1 3 8.1 1.3 11.1 4.9 5 15 20 165 13.7 0.2 14.4 13.3 09/01/2006 11:30:00 6.1 1.3 9.5 3 5 1.3 9.1 1.5 6.2 1.4 10.7 3.4 360 14 12 165 13.9 0.5 14.6 13.3 09/01/2006 11:40:00 5.2 0.7 7.2 3.4 5.1 0.9 7.2 2.6 5.1 0.7 7.2 3.4 332 17 330 165 14.9 0.2 15.2 14.4 09/01/2006 11:50:00 5 1 7.2 2.6 4.6 1 6.5 1.9 5 1 7.6 2.6 343 17 12 165 14.2 0.2 14.6 13.8 09/01/2006 12:00:00 6.3 1.2 10.7 4.2 5.2 1.4 9.9 2.3 6.3 1.2 9.5 4.2 357 12 360 165 13.5 0.1 13.8 13.3 09/01/2006 12:10:00 8.3 1.6 12.6 5.3 6.7 1.5 12.2 3.4 8.3 1.6 12.2 4.6 360 15 13 165 13.3 0 13.5 12.7 09/01/2006 12:20:00 6.4 1.2 9.5 2.3 5.5 1.4 9.1 2.6 6.1 1.2 9.5 3 7 17 28 165 13.5 0.2 14.1 13.3 09/01/2006 12:30:00 7 1.3 10.7 3.4 6.2 1.7 11.1 2.6 7.1 1.4 11.8 3.8 9 17 26 165 13.5 0.2 14.1 13.3 09/01/2006 12:40:00 5.6 1.2 9.5 2.6 5 1.4 9.1 1.9 5.6 1.1 9.9 3 352 14 43 165 12.9 0.2 13.3 12.5 09/01/2006 12:50:00 6.1 1.2 9.1 3 5.5 1.5 8.8 2.3 5.9 1.2 9.1 3 348 11 336 165 13.3 0.6 14.6 12.2 09/01/2006 13:00:00 8.3 1.7 13 4.6 6.9 1.9 11.8 3 8.1 1.8 13 4.6 355 10 13 165 14.7 0 15.2 14.4 09/01/2006 13:10:00 6.6 1.3 10.3 3.8 5.9 1.3 10.3 3 6.5 1.5 11.1 3.4 355 17 25 165 14.2 0.2 14.6 13.3 09/01/2006 13:20:00 8.4 1.5 12.6 4.9 6.9 1.6 11.5 3.4 8.3 1.5 12.2 4.9 360 13 9 165 14 0.1 14.4 13.5 09/01/2006 13:30:00 7.8 1.3 12.6 5.3 6.1 1.7 12.2 3 7.9 1.3 12.6 4.6 3 11 12 165 13.6 0 13.8 13.3 09/01/2006 13:40:00 7.2 2 12.2 4.2 6.1 2.2 11.5 2.3 7.2 2 11.8 3.4 4 13 351 165 13.7 0.1 14.4 13.5 09/01/2006 13:50:00 8.3 1.4 10.7 3.8 6.8 1.6 10.3 2.3 8.3 1.3 11.1 4.6 358 12 4 165 14 0 14.4 13.8 09/01/2006 14:00:00 8.5 1.2 12.2 4.9 6.7 1.4 10.7 3.8 8.6 1.3 12.2 4.9 354 13 10 165 13.9 0 14.1 13.5 09/01/2006 14:10:00 7.9 1.5 12.2 4.6 6.6 1.6 11.8 3 7.7 1.6 12.2 4.2 355 17 20 165 14.4 0.2 14.6 14.1 09/01/2006 14:20:00 8.2 1.9 12.2 3.8 7.1 2.4 12.2 2.3 8.2 1.9 12.6 3.8 11 11 19 165 13.5 0.3 14.4 13 09/01/2006 14:30:00 7.8 1.8 13.3 3.4 6.2 1.6 11.8 3.4 8.1 1.7 12.6 4.2 359 12 16 165 13.2 0.3 14.1 12.5 09/01/2006 14:40:00 7.5 1.6 11.8 3.8 6 1.5 11.1 2.3 7.4 1.7 11.1 3.4 360 13 13 165 14.4 0.2 14.9 13.8 09/01/2006 14:50:00 9.6 1.7 13.7 5.7 8.3 2.1 13.3 3.8 9.4 1.8 13.3 4.9 6 16 42 165 14.1 0.3 14.9 13.5 09/01/2006 15:00:00 8.3 1.4 13 3.8 6.9 1.7 11.8 2.6 8.3 1.5 12.6 3 358 16 6 165 13.7 0 14.1 13.5 09/01/2006 15:10:00 5.5 1.2 8.4 1.5 5 1.4 9.1 1.5 5.4 1.2 9.5 2.3 348 20 332 165 14 0 14.1 13.8 09/01/2006 15:20:00 5.2 1 8 2.6 4.5 1.2 7.6 1.5 5.2 1.1 8.8 2.6 354 16 16 165 14.6 0.5 15.7 13.8 09/01/2006 15:30:00 4.6 1 7.6 2.3 4.2 1 6.8 1.9 4.4 0.9 7.2 1.9 346 18 5 165 15.9 0.2 16.3 15.5 09/01/2006 15:40:00 6.8 1.2 11.1 3.8 6.8 1.3 11.1 3.8 6.2 1.3 11.1 3 322 13 315 165 14.8 0.3 16 14.6 09/01/2006 15:50:00 7.2 1.5 11.5 4.2 6.8 2 11.1 1.9 7.2 1.5 11.1 4.2 337 14 337 165 14 0.2 14.6 13.3 09/01/2006 16:00:00 6 1.3 9.5 3 5.9 1.4 9.9 1.9 5.8 1.2 10.3 3.4 329 15 342 165 13.5 0 13.8 13.5 09/01/2006 16:10:00 7.3 1.6 11.8 4.6 7.2 1.5 11.8 4.2 6.9 1.6 11.8 3.8 323 11 348 165 13.3 0 13.5 13 09/01/2006 16:20:00 9 1.5 12.6 4.9 8.8 1.7 12.2 3.4 8.8 1.5 12.2 5.3 333 10 340 165 13 0.1 13.3 12.5 09/01/2006 16:30:00 9.6 1.3 13 6.5 9.7 1.4 13 6.5 9.5 1.4 13 6.5 339 7 339 165 12.9 0 13 12.5 09/01/2006 16:40:00 7.7 1.5 13 5.3 7.6 1.5 12.6 4.9 7.5 1.5 12.6 4.6 337 9 322 165 12.9 0.1 13 12.5 09/01/2006 16:50:00 6.6 1.2 9.9 4.2 6.3 1 9.1 2.6 6.3 1.1 9.1 3.8 340 13 7 165 12.9 0.1 13 12.5 09/01/2006 17:00:00 5.8 1.1 9.1 3.4 5.3 1.3 9.5 1.1 5.5 1 8.8 3.4 341 16 349 165 12.9 0 13 12.7 09/01/2006 17:10:00 4.6 2.8 9.5 0.4 4.5 2.8 9.9 0.4 4.4 2.8 9.9 0.4 6 45 36 165 12.3 0.4 12.7 11.4 09/01/2006 17:20:00 8.2 1.3 10.7 4.9 8.2 1.4 10.7 4.2 8.4 1.5 11.1 4.9 30 7 34 165 10.9 0.2 11.4 10.6 09/01/2006 17:30:00 7.8 0.9 9.5 4.6 7.6 0.9 9.5 4.6 7.6 1 9.5 4.9 23 7 26 165 10.5 0 10.9 10.3 09/01/2006 17:40:00 7.6 1 10.7 4.6 7.3 1 9.5 4.2 7.3 1.1 10.7 4.9 25 9 9 165 10.6 0 10.9 10.6 09/01/2006 17:50:00 7.9 0.8 9.5 6.1 7.8 0.9 9.1 4.9 7.6 0.9 9.5 5.3 25 6 37 165 10.7 0.1 11.1 10.6 09/01/2006 18:00:00 6.2 0.7 8 3.8 6.1 0.7 7.6 3.8 5.7 0.9 7.6 3.4 27 8 3 165 10.9 0 11.1 10.9 09/01/2006 18:10:00 5.7 0.7 7.6 4.2 5.5 0.9 7.2 2.6 5.3 0.8 7.2 3 23 11 30 165 10.9 0 11.4 10.9 09/01/2006 18:20:00 5.8 0.7 8.4 4.2 5.2 0.8 7.6 2.6 5.2 0.7 7.2 2.6 15 9 11 165 11.1 0.1 11.7 10.9 09/01/2006 18:30:00 5.5 0.9 7.6 3.4 4.4 1 7.2 2.3 4.9 0.8 7.2 2.6 3 16 4 165 11.3 0 11.7 11.1 09/01/2006 18:40:00 4.8 1 7.2 2.3 4.1 1.1 6.8 1.9 4.4 0.8 6.8 2.3 346 15 350 165 11.4 0 11.7 11.1 09/01/2006 18:50:00 5.1 1 7.6 2.6 5.1 1 8 2.6 5 0.8 7.2 3.4 336 8 338 165 11.4 0 11.9 11.1 09/01/2006 19:00:00 5.6 1 8 3.4 5.5 1 7.6 2.6 5.4 1 8 3 338 9 328 165 11.5 0.1 11.7 11.1 09/01/2006 19:10:00 5.6 0.9 8 3.4 4.9 1 7.6 2.3 5 0.8 7.2 3 351 9 349 165 11.5 0.1 11.9 11.4 09/01/2006 19:20:00 6.1 1 8.4 4.2 5 1 7.6 2.6 5.4 1.2 8 2.6 356 12 358 165 11.6 0.1 11.9 11.4 09/01/2006 19:30:00 6.3 1.2 9.1 3 5.2 1.4 8.8 2.3 5.6 1.2 8.8 2.3 353 9 356 165 11.7 0.1 11.9 11.4 09/01/2006 19:40:00 7.5 1.1 9.5 3.8 6 1.3 9.1 3 6.8 1.2 9.9 2.3 353 8 359 165 11.6 0.2 12.2 11.4 09/01/2006 19:50:00 8.1 0.8 9.5 5.7 7.3 1.4 9.9 3.4 7.5 0.8 9.5 5.3 351 6 356 165 11.6 0.2 11.9 11.1 09/01/2006 20:00:00 7.8 0.9 9.5 4.6 6.5 1.5 9.5 3.4 7.5 1 9.5 4.2 352 7 358 165 11.6 0.2 11.9 11.1 09/01/2006 20:10:00 7.1 0.8 9.9 4.9 6.4 1.2 8.8 3.4 6.7 1 8.8 4.2 349 8 354 165 11.5 0.2 11.9 11.1 09/01/2006 20:20:00 7.8 0.8 11.1 5.3 6.2 1.3 9.5 3.4 7.5 0.9 11.1 5.7 355 6 9 165 11.5 0.2 11.9 11.1 09/01/2006 20:30:00 7.7 0.8 9.5 4.6 6.5 1.3 9.1 3.4 7.4 0.9 9.9 4.2 352 6 355 165 11.4 0.2 11.7 10.9 09/01/2006 20:40:00 6.6 1 8.8 4.6 5.8 1.1 8.8 3 5.8 1.1 8 3.4 351 7 355 165 11.1 0.1 11.7 10.9 09/01/2006 20:50:00 7.6 0.6 8.8 5.7 5.8 1.5 9.5 2.6 7.2 0.6 8.8 4.9 355 6 360 165 11.1 0 11.4 10.9 09/01/2006 21:00:00 8.1 0.8 10.3 5.7 6.9 1.6 9.5 2.6 7.4 1 9.9 4.2 353 7 13 165 11.1 0 11.1 10.6 09/01/2006 21:10:00 8 0.8 10.7 5.7 6.4 1.6 9.9 3.8 7.3 0.9 9.5 4.9 355 8 2 165 10.9 0 11.1 10.9 09/01/2006 21:20:00 8.1 0.7 9.5 6.5 5.9 1.4 9.5 3.4 7.5 0.7 9.5 5.7 357 6 346 165 10.9 0 11.1 10.9 09/01/2006 21:30:00 6.3 0.8 8.4 4.6 4.3 1 7.6 2.3 5.8 0.9 8.4 3.8 0 6 5 165 10.8 0.1 11.1 10.6 09/01/2006 21:40:00 6.8 1.1 9.1 4.2 5 1.4 8.4 2.3 6.3 1.2 8.8 3.8 356 6 355 165 10.6 0.1 10.9 10.3 09/01/2006 21:50:00 6.4 0.8 8.4 3.8 5.4 1.1 8 3 5.8 1 8.8 3 350 11 340 165 10.7 0.1 11.1 10.3 09/01/2006 22:00:00 6.1 1 9.1 4.2 5 1.2 8.4 2.3 5.8 1.2 9.5 3.4 349 12 360 165 10.5 0.1 10.9 10.1 09/01/2006 22:10:00 5.9 0.7 7.6 4.2 5 1.2 7.6 2.3 5.7 0.8 8 3.8 352 10 347 165 10.6 0.1 11.1 10.1 09/01/2006 22:20:00 7.7 1.1 12.2 5.3 7.6 1.1 11.8 4.9 7.4 1.1 12.6 4.9 338 9 329 165 10.3 0.1 10.9 9.8 09/01/2006 22:30:00 7.8 1.5 12.6 4.6 7.6 1.7 12.2 2.6 7.5 1.7 12.2 4.6 337 9 336 165 10.7 0.1 11.1 10.3 09/01/2006 22:40:00 7.5 1.5 10.3 3 7.2 1.7 9.9 2.3 7.1 1.2 9.5 4.2 338 8 340 165 10.5 0 10.9 10.1 09/01/2006 22:50:00 7.9 0.9 10.7 5.3 7.7 1 10.3 5.3 7.1 1.1 10.7 3.4 342 8 339 165 10.7 0.1 10.9 10.3 09/01/2006 23:00:00 7.8 0.9 9.9 5.3 7.6 0.8 9.9 5.3 7.2 0.9 9.5 4.9 338 7 337 165 10.7 0 11.1 10.6 09/01/2006 23:10:00 7.1 1.1 10.3 4.6 7 1.1 9.5 4.6 6.6 1 9.1 4.2 336 8 335 165 10.8 0 11.1 10.6 09/01/2006 23:20:00 7 0.8 9.5 4.9 6 1.5 9.9 2.6 6.6 0.9 9.5 4.6 351 8 341 165 10.9 0 11.1 10.9 09/01/2006 23:30:00 7.2 0.8 9.5 5.7 6.9 1 9.9 3.4 6.9 0.7 9.1 5.3 341 10 354 165 10.8 0.1 11.4 10.3 09/01/2006 23:40:00 6.7 0.7 9.5 4.9 6.6 0.7 9.1 4.6 6.3 0.8 8.8 4.6 337 9 321 165 10.9 0 11.1 10.6 09/01/2006 23:50:00 7.4 1.1 11.5 4.6 7.1 1.2 9.9 3.4 6.8 1.1 9.9 3.8 339 10 359 165 10.8 0 11.1 10.3 09/02/2006 00:00:00 6.2 1 8.8 3.4 5.9 1 8.8 2.6 5.7 1.1 8.8 1.9 338 11 356 165 10.7 0.1 11.1 10.1 09/02/2006 00:10:00 5.7 1 8.4 3.4 5.4 1.1 8 1.9 5.1 0.9 7.6 3 342 9 338 165 10.6 0.1 10.9 10.1 09/02/2006 00:20:00 5 1.2 8 3 4.6 1.3 8 1.9 4.5 1.1 8 1.9 345 10 339 165 10.6 0.1 10.9 10.3 09/02/2006 00:30:00 4.7 1 7.6 2.6 4.5 1.1 7.6 2.3 4.4 1.1 7.2 2.3 341 11 343 165 10.7 0.1 11.1 10.3 09/02/2006 00:40:00 4.7 0.6 6.5 3 4.3 1 6.5 1.5 4.3 0.6 6.1 2.3 346 10 333 165 10.5 0 11.1 9.8 09/02/2006 00:50:00 4.9 0.8 6.8 3 3.9 1 6.5 1.5 4.3 0.7 6.1 1.9 357 10 5 165 10.4 0 10.6 9.8 09/02/2006 01:00:00 5 0.8 7.6 3.4 4.1 1.2 7.6 1.9 4.4 0.7 6.5 1.9 352 11 10 165 10.5 0 10.6 9.8 09/02/2006 01:10:00 4.2 0.6 5.7 2.6 3 0.8 5.3 1.5 3.9 0.7 5.3 2.3 360 9 347 165 10.5 0 10.9 9.8 09/02/2006 01:20:00 4.1 0.4 5.3 3 3.4 0.8 4.6 1.5 4 0.5 5.3 2.6 349 8 12 165 10.2 0 10.6 9.6 09/02/2006 01:30:00 4 0.6 6.1 2.6 3.8 0.8 5.7 1.5 3.9 0.6 5.7 2.3 334 13 328 165 10 0 10.6 9.8 09/02/2006 01:40:00 5.2 1 7.2 3 5.1 1.1 7.6 3 5.1 1 7.6 3 330 11 344 165 10.4 0.1 10.9 9.8 09/02/2006 01:50:00 4.6 0.7 6.5 3 4.4 0.7 6.5 2.3 4.5 0.6 6.5 3 330 9 343 165 10.7 0.1 11.4 10.3 09/02/2006 02:00:00 5.3 0.5 6.8 4.2 5 0.7 6.5 3 5.1 0.6 6.8 3.4 339 7 328 165 10.5 0 10.9 10.3 09/02/2006 02:10:00 5.6 0.6 7.2 4.2 5.5 0.7 7.2 2.3 5.6 0.6 7.2 4.6 341 6 338 165 10.4 0 10.6 9.8 09/02/2006 02:20:00 6 0.8 8 4.2 5.9 0.8 8 4.2 5.8 0.7 8 4.6 340 6 338 165 10.2 0 10.3 9.6 09/02/2006 02:30:00 6.1 0.7 8 4.6 5.9 0.8 8 4.2 6 0.7 8 4.6 342 7 339 165 10.5 0 10.9 9.8 09/02/2006 02:40:00 5.7 0.9 7.6 3.4 5.3 1.2 7.6 2.6 5.5 0.8 7.6 3.8 343 8 343 165 10.5 0 10.9 10.3 09/02/2006 02:50:00 7 1 8.8 4.9 6.9 1.1 9.1 4.2 6.8 1 8.8 4.9 342 6 349 165 10.7 0.1 11.1 10.3 09/02/2006 03:00:00 6.4 0.8 8.8 4.6 6.1 1.1 8.8 3 6.4 0.9 8.4 4.2 347 6 345 165 10.8 0 11.1 10.3 09/02/2006 03:10:00 7 0.8 9.1 5.3 6.9 0.8 9.1 5.3 6.8 0.7 8.8 5.3 337 6 339 165 10.8 0 11.1 10.3 09/02/2006 03:20:00 5.6 0.5 7.2 4.2 5.4 0.6 7.2 3.4 5.3 0.6 6.8 4.2 340 6 338 165 10.7 0.1 11.1 10.3 09/02/2006 03:30:00 5.6 0.8 7.6 3.8 5.3 1 7.6 2.3 5.4 0.8 7.6 3.8 340 8 336 165 10.7 0.1 11.1 10.6 09/02/2006 03:40:00 5.3 0.7 7.2 3.4 5.1 0.9 7.6 2.3 5.2 0.7 6.8 3.4 342 7 341 165 10.7 0 11.4 10.6 09/02/2006 03:50:00 5.9 0.6 7.2 4.2 5.8 0.7 7.2 3.8 5.7 0.6 7.2 4.6 333 14 339 165 10.8 0 11.1 10.6 09/02/2006 04:00:00 4.3 0.8 6.5 2.3 4.2 0.8 6.5 2.3 4.3 0.9 6.8 1.5 320 12 342 165 11.1 0 11.4 10.9 09/02/2006 04:10:00 3.5 0.5 4.6 2.3 3.4 0.5 4.9 2.3 3.5 0.5 4.9 1.9 326 8 318 165 11 0.1 11.4 10.6 09/02/2006 04:20:00 3.5 0.7 5.3 2.3 3.3 0.7 5.3 1.9 3.4 0.7 5.7 2.3 327 12 331 165 11.3 0 11.7 10.9 09/02/2006 04:30:00 2.9 0.8 4.6 1.1 2.8 0.7 4.6 0.7 2.9 0.6 4.2 1.5 327 12 327 165 11.4 0 11.9 11.1 09/02/2006 04:40:00 3 0.6 4.9 1.5 2.9 0.6 4.9 1.5 3 0.6 4.9 1.1 322 9 332 165 11.5 0.1 11.7 10.9 09/02/2006 04:50:00 2.5 0.5 3.8 1.1 2.4 0.5 3.8 1.1 2.4 0.4 3.4 1.5 321 10 332 165 11.3 0 11.7 11.1 09/02/2006 05:00:00 2.7 0.6 4.2 1.5 2.6 0.6 4.6 1.5 2.7 0.6 4.2 1.1 328 11 349 165 11.3 0.2 11.9 10.9 09/02/2006 05:10:00 2.1 0.4 3 1.1 2.1 0.5 3.4 0.7 2.4 0.4 3 1.1 334 12 321 165 10.9 0 11.1 10.6 09/02/2006 05:20:00 2.1 0.4 3 1.5 2 0.4 2.6 1.1 2.4 0.4 3.4 1.1 334 12 2 165 10.9 0 11.1 10.9 09/02/2006 05:30:00 1.9 0.6 3.4 0.7 1.6 0.7 3.4 0.4 2.2 0.5 3.4 1.5 349 9 349 165 11 0 11.4 10.9 09/02/2006 05:40:00 3.1 0.5 4.2 1.9 2 0.8 3.8 0.7 3.2 0.4 4.2 2.3 356 6 348 165 10.9 0 11.1 10.9 09/02/2006 05:50:00 3.4 0.3 4.2 2.6 2.1 0.7 3.8 0.7 3.6 0.3 4.6 3 356 5 355 165 10.9 0 11.1 10.9 09/02/2006 06:00:00 3.2 0.3 3.8 2.3 2.1 0.7 3.8 0.7 3.4 0.3 4.2 2.6 354 6 347 165 10.8 0 11.1 10.6 09/02/2006 06:10:00 3.3 0.4 4.2 2.3 2.1 0.8 3.8 0.7 3.5 0.4 4.6 2.6 356 6 359 165 10.7 0 11.1 10.9 09/02/2006 06:20:00 3.6 0.5 4.6 2.3 3.2 0.8 4.9 1.5 3.8 0.4 4.6 2.6 347 6 344 165 10.6 0 11.1 10.3 09/02/2006 06:30:00 3.6 0.4 4.9 2.3 3.2 0.8 4.9 1.1 3.5 0.4 4.6 2.6 346 8 351 165 10.8 0 11.4 10.6 09/02/2006 06:40:00 3.6 0.4 4.6 2.3 3.2 0.9 4.6 0.7 3.7 0.4 4.6 3 346 8 333 165 11.3 0.1 11.4 10.9 09/02/2006 06:50:00 3.8 0.5 5.3 2.3 3.3 0.9 5.3 1.1 3.9 0.4 4.9 2.6 349 7 2 165 11.5 0.1 11.7 10.9 09/02/2006 07:00:00 3.1 0.6 4.2 1.1 3.1 0.6 4.2 1.5 3.1 0.6 4.2 1.5 328 14 343 165 11.7 0.2 12.2 11.1 09/02/2006 07:10:00 1.7 0.7 3 0.4 1.4 0.8 3 0.4 1.8 0.7 3.4 0.4 339 15 333 165 12.1 0.1 12.5 11.7 09/02/2006 07:20:00 1.2 0.5 2.6 0.4 1.1 0.6 2.6 0.4 1.4 0.6 3 0.4 302 14 310 165 12.4 0 12.7 11.9 09/02/2006 07:30:00 0.7 0.4 1.9 0.4 0.6 0.4 1.9 0.4 1 0.6 2.6 0.4 270 11 276 165 12.3 0 12.7 12.2 09/02/2006 07:40:00 0.4 0.1 1.1 0.4 0.4 0 0.7 0.4 0.5 0.3 1.9 0.4 295 4 284 165 12.4 0 12.5 12.2 09/02/2006 07:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 36 49 165 165 12.7 0.2 13.3 11.9 09/02/2006 08:00:00 1.1 0.6 2.3 0.4 0.9 0.6 2.6 0.4 1.1 0.7 2.6 0.4 63 6 56 165 13.1 0 13.3 12.7 09/02/2006 08:10:00 0.6 0.4 1.5 0.4 0.5 0.3 1.5 0.4 0.6 0.4 1.9 0.4 26 17 62 165 13.5 0.1 13.8 13 09/02/2006 08:20:00 0.5 0.4 1.5 0.4 0.4 0.2 1.1 0.4 0.5 0.3 1.5 0.4 28 5 24 165 13.3 0 13.8 13 09/02/2006 08:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 31 0 165 165 13.3 0 13.5 13 09/02/2006 08:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 31 0 165 165 13.5 0 13.8 13.3 09/02/2006 08:50:00 0.4 0.1 1.1 0.4 0.4 0 0.7 0.4 0.4 0.2 1.5 0.4 21 47 41 165 15.5 1 17.1 13.8 09/02/2006 09:00:00 0.4 0.3 1.5 0.4 0.4 0.1 1.5 0.4 0.5 0.2 1.5 0.4 125 117 11 165 16.8 0.3 17.4 16.3 09/02/2006 09:10:00 0.4 0.1 1.1 0.4 0.4 0 0.7 0.4 0.5 0.3 1.5 0.4 163 39 237 165 15 0.7 16.6 14.1 09/02/2006 09:20:00 0.5 0.3 2.3 0.4 0.4 0.2 2.3 0.4 0.5 0.4 2.3 0.4 168 15 156 165 14.2 0.3 14.9 13.8 09/02/2006 09:30:00 1 0.6 3 0.4 0.7 0.6 2.6 0.4 1.2 0.5 2.6 0.4 95 21 126 165 14.4 0.4 15.2 13.5 09/02/2006 09:40:00 0.7 0.4 1.9 0.4 0.5 0.3 1.5 0.4 0.9 0.5 2.3 0.4 108 3 116 165 13.3 0 13.8 13 09/02/2006 09:50:00 0.4 0 0.7 0.4 0.4 0 0.4 0.4 0.4 0.1 1.1 0.4 106 1 107 165 13 0 13 13 09/02/2006 10:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 106 2 165 165 12.9 0 13 12.7 09/02/2006 10:10:00 0.8 0.4 1.9 0.4 0.5 0.2 1.5 0.4 1.1 0.4 2.3 0.4 116 10 128 165 13.1 0.1 13.3 12.7 09/02/2006 10:20:00 0.6 0.4 1.5 0.4 0.4 0.2 1.5 0.4 0.7 0.4 1.9 0.4 117 9 122 165 12.8 0 13.3 12.5 09/02/2006 10:30:00 0.6 0.4 1.9 0.4 0.4 0.2 1.1 0.4 0.9 0.4 1.9 0.4 102 5 102 165 12.9 0.1 13.3 12.2 09/02/2006 10:40:00 0.9 0.4 1.9 0.4 0.6 0.3 1.5 0.4 1 0.3 1.5 0.4 124 4 123 165 12.6 0 12.7 12.5 09/02/2006 10:50:00 0.5 0.2 1.5 0.4 0.4 0.1 1.1 0.4 0.8 0.4 1.9 0.4 132 16 148 165 12.6 0 13 12.5 09/02/2006 11:00:00 0.8 0.4 1.9 0.4 0.6 0.4 1.9 0.4 1.1 0.5 2.3 0.4 125 9 127 165 12.4 0 12.7 12.5 09/02/2006 11:10:00 1.6 0.5 2.6 0.4 1.5 0.5 2.6 0.4 1.8 0.4 2.6 0.7 125 12 117 165 12.4 0 12.5 12.2 09/02/2006 11:20:00 1 0.5 2.6 0.4 1 0.5 2.6 0.4 1.5 0.4 2.6 0.4 130 18 128 165 12.7 0 13 12.5 09/02/2006 11:30:00 1.7 0.5 3 0.4 1.5 0.5 2.6 0.4 2.1 0.4 3 1.1 149 13 155 165 12.6 0.2 13 12.2 09/02/2006 11:40:00 0.6 0.4 2.3 0.4 0.6 0.4 2.3 0.4 1.1 0.6 2.6 0.4 145 22 165 165 12.5 0.1 13 12.2 09/02/2006 11:50:00 0.5 0.4 1.9 0.4 0.5 0.4 2.3 0.4 0.9 0.5 2.3 0.4 133 30 115 165 13.1 0 13.3 12.7 09/02/2006 12:00:00 0.5 0.4 2.3 0.4 0.5 0.4 2.3 0.4 0.7 0.5 2.3 0.4 159 22 173 165 13.5 0.3 14.4 13 09/02/2006 12:10:00 1.1 0.7 2.6 0.4 1 0.7 2.6 0.4 1.4 0.6 3 0.4 148 27 163 165 14.4 0 14.6 14.4 09/02/2006 12:20:00 1.1 0.6 3 0.4 1 0.6 3 0.4 1.3 0.6 2.6 0.4 167 32 164 165 14.4 0 14.9 14.1 09/02/2006 12:30:00 1.6 0.8 3.4 0.4 1.5 0.8 3.4 0.4 2 0.7 4.2 0.4 143 20 145 165 14.3 0.1 14.6 14.1 09/02/2006 12:40:00 1.6 0.8 3.8 0.4 1.6 0.9 4.2 0.4 2 0.8 4.2 0.4 130 19 108 165 14.2 0.1 14.6 13.8 09/02/2006 12:50:00 1.7 1 3.8 0.4 1.7 1 4.2 0.4 2.1 0.9 4.2 0.4 130 20 147 165 14.8 0.2 15.5 14.4 09/02/2006 13:00:00 2.3 0.6 3.8 0.4 2.2 0.6 3.8 0.4 2.4 0.6 3.8 0.7 150 17 124 165 14.5 0.2 15.2 14.1 09/02/2006 13:10:00 2.2 0.6 3.4 0.4 2 0.6 3.4 0.4 2.5 0.6 3.8 1.1 141 15 129 165 14 0 14.6 13.8 09/02/2006 13:20:00 1.6 0.7 3.4 0.4 1.4 0.8 3 0.4 2 0.7 3.8 0.4 142 17 174 165 14.6 0.4 15.2 13.8 09/02/2006 13:30:00 1.6 0.6 3 0.4 1.6 0.6 3 0.4 2 0.5 3.4 0.4 138 20 140 165 14.2 0.3 15.2 13.5 09/02/2006 13:40:00 1 0.5 2.3 0.4 1.1 0.5 2.3 0.4 1.5 0.4 2.6 0.4 140 17 147 165 13.8 0.2 14.1 13.3 09/02/2006 13:50:00 0.8 0.5 2.3 0.4 0.8 0.5 2.6 0.4 1.2 0.5 3 0.4 125 22 142 165 13.9 0 14.1 13.8 09/02/2006 14:00:00 0.6 0.4 2.3 0.4 0.6 0.4 2.3 0.4 0.9 0.5 2.6 0.4 89 29 73 165 14.4 0.1 14.6 14.1 09/02/2006 14:10:00 1.5 0.8 3 0.4 1.5 0.7 3 0.4 2 0.7 3.8 0.4 140 18 131 165 14.4 0 14.6 13.8 09/02/2006 14:20:00 1.9 0.6 3.4 0.4 1.8 0.6 3.4 0.4 2.2 0.5 3.8 1.1 157 11 162 165 13.3 0.3 14.1 12.7 09/02/2006 14:30:00 1.7 0.5 3 0.4 1.6 0.6 3 0.4 1.8 0.5 3 0.4 120 18 122 165 13.3 0.1 13.5 13 09/02/2006 14:40:00 1.2 0.6 2.6 0.4 1 0.6 2.3 0.4 1.6 0.5 2.6 0.4 141 13 147 165 13.3 0.1 13.5 13 09/02/2006 14:50:00 1.3 0.6 3 0.4 1.1 0.6 3 0.4 1.7 0.4 2.6 0.4 143 17 111 165 12.7 0 13 12.7 09/02/2006 15:00:00 1.5 0.6 2.6 0.4 1.6 0.6 2.6 0.4 1.7 0.5 3 0.7 107 13 116 165 13.1 0.2 13.5 12.7 09/02/2006 15:10:00 1 0.6 3 0.4 1.2 0.6 3.4 0.4 1.3 0.6 3.4 0.4 114 27 141 165 13.7 0 13.8 13.3 09/02/2006 15:20:00 1.9 0.5 3.4 0.4 2 0.5 3 0.7 2.2 0.6 3.4 0.4 126 10 132 165 13.5 0 14.1 13.3 09/02/2006 15:30:00 1.6 0.7 2.6 0.4 1.6 0.8 3 0.4 2.1 0.6 3 0.4 123 17 110 165 12.9 0.1 13.5 12.7 09/02/2006 15:40:00 1.8 0.6 3 0.4 1.7 0.7 3.4 0.4 2 0.6 3.8 0.4 113 12 116 165 12.7 0 13 12.7 09/02/2006 15:50:00 2.3 0.5 3.4 0.4 2.4 0.5 3.4 0.7 2.7 0.4 3.8 1.5 105 9 94 165 12.9 0 13 12.7 09/02/2006 16:00:00 2.6 0.4 3.8 1.5 2.6 0.4 3.4 1.5 2.8 0.4 3.8 1.5 115 7 107 165 13.1 0 13.3 12.7 09/02/2006 16:10:00 2.4 0.4 3.8 1.1 2.3 0.4 3.8 0.7 2.6 0.4 4.2 1.5 114 7 126 165 12.6 0.2 13 12.2 09/02/2006 16:20:00 1.9 0.3 2.6 1.1 1.8 0.3 2.6 0.7 2.2 0.3 3.4 1.5 113 7 116 165 12.6 0 13 12.5 09/02/2006 16:30:00 1.9 0.4 3 0.7 1.8 0.4 2.6 0.7 2.1 0.3 3 1.5 115 9 128 165 12.4 0 12.7 12.2 09/02/2006 16:40:00 1.3 0.4 2.3 0.4 1.1 0.4 2.3 0.4 1.7 0.3 2.6 0.7 98 12 94 165 12.5 0 12.7 12.2 09/02/2006 16:50:00 1.5 0.3 2.6 0.7 1.2 0.3 2.3 0.4 1.8 0.3 2.6 1.5 117 5 122 165 12.6 0 12.7 12.5 09/02/2006 17:00:00 2.1 0.4 3 1.5 2 0.4 3 1.1 2.3 0.3 3 1.5 109 8 105 165 12.2 0 12.5 11.9 09/02/2006 17:10:00 2.6 0.3 3.4 1.5 2.6 0.4 3.4 1.5 2.7 0.3 3.4 1.9 113 6 113 165 11.7 0 11.9 11.4 09/02/2006 17:20:00 2.8 0.3 3.4 2.3 2.9 0.3 3.4 1.9 2.7 0.3 3.4 1.9 114 6 116 165 11.5 0.1 11.7 11.1 09/02/2006 17:30:00 2.3 0.3 3 1.5 2.3 0.3 3.4 1.1 2.5 0.3 3.4 1.9 117 5 110 165 11.5 0 11.7 11.1 09/02/2006 17:40:00 1.7 0.2 2.3 1.1 1.5 0.3 2.3 0.4 1.8 0.3 2.3 1.1 120 6 118 165 11.5 0 11.7 11.4 09/02/2006 17:50:00 1.9 0.2 2.3 1.1 1.7 0.3 2.3 1.1 2 0.2 2.6 1.5 136 3 138 165 11.5 0 11.7 10.9 09/02/2006 18:00:00 1.2 0.3 1.9 0.7 0.9 0.3 1.9 0.4 1.6 0.2 2.3 1.1 139 4 129 165 11.3 0 11.7 11.1 09/02/2006 18:10:00 1.5 0.4 2.3 0.4 1.3 0.4 1.9 0.4 1.8 0.3 2.3 0.7 145 9 141 165 11.1 0 11.4 10.9 09/02/2006 18:20:00 0.6 0.4 1.9 0.4 0.5 0.3 1.9 0.4 0.7 0.5 1.9 0.4 120 10 138 165 10.9 0 11.1 10.9 09/02/2006 18:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0.1 1.1 0.4 116 0 165 165 10.7 0 10.9 10.9 09/02/2006 18:40:00 0.5 0.3 1.5 0.4 0.4 0.2 1.1 0.4 0.7 0.4 1.5 0.4 112 5 116 165 10.7 0 10.9 10.6 09/02/2006 18:50:00 0.4 0.2 1.5 0.4 0.4 0.1 1.1 0.4 0.4 0.1 1.1 0.4 86 5 70 165 10.7 0 10.9 10.6 09/02/2006 19:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 85 0 165 165 10.7 0 10.9 10.9 09/02/2006 19:10:00 0.4 0.1 0.7 0.4 0.4 0 0.4 0.4 0.5 0.2 1.1 0.4 67 21 42 165 10.7 0 10.9 10.3 09/02/2006 19:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 42 0 165 165 10.7 0 10.9 10.6 09/02/2006 19:30:00 0.4 0.1 1.1 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 42 0 42 165 10.6 0 10.9 10.3 09/02/2006 19:40:00 0.6 0.4 1.9 0.4 0.4 0.2 1.5 0.4 0.4 0.2 1.5 0.4 42 15 68 165 10.5 0 10.9 10.3 09/02/2006 19:50:00 0.5 0.3 1.9 0.4 0.4 0.2 1.5 0.4 0.4 0.1 1.1 0.4 55 9 66 165 10.5 0 10.9 10.3 09/02/2006 20:00:00 0.6 0.3 1.5 0.4 0.4 0.2 1.5 0.4 0.7 0.4 1.5 0.4 72 5 72 165 10.6 0.1 10.9 10.3 09/02/2006 20:10:00 0.5 0.2 1.1 0.4 0.4 0 0.4 0.4 0.4 0.2 1.1 0.4 65 10 70 165 10.7 0.1 10.9 10.3 09/02/2006 20:20:00 0.5 0.3 1.5 0.4 0.4 0.1 1.1 0.4 0.7 0.3 1.5 0.4 46 5 36 165 10.4 0 10.9 10.3 09/02/2006 20:30:00 0.7 0.4 1.9 0.4 0.4 0.2 1.1 0.4 0.8 0.4 1.5 0.4 69 13 74 165 10.3 0 10.6 9.8 09/02/2006 20:40:00 0.5 0.2 1.1 0.4 0.4 0 0.4 0.4 0.4 0.2 1.1 0.4 82 10 64 165 10.2 0.1 10.6 9.8 09/02/2006 20:50:00 0.4 0.1 0.7 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 48 11 55 165 10.1 0.2 10.3 9.6 09/02/2006 21:00:00 0.7 0.4 1.5 0.4 0.5 0.2 1.1 0.4 0.8 0.5 1.5 0.4 19 23 355 165 10 0.1 10.3 9.6 09/02/2006 21:10:00 1.2 0.2 1.5 0.7 0.6 0.2 1.1 0.4 1.4 0.2 1.9 1.1 351 0 351 165 9.9 0 10.3 9.6 09/02/2006 21:20:00 1.2 0.2 1.5 0.7 0.6 0.3 1.1 0.4 1.4 0.2 1.9 1.1 348 3 351 165 9.8 0 10.1 9.6 09/02/2006 21:30:00 0.9 0.2 1.1 0.7 0.4 0 0.7 0.4 1.2 0.2 1.5 0.7 344 0 344 165 9.8 0 10.1 9.3 09/02/2006 21:40:00 1 0.2 1.5 0.7 0.4 0 0.7 0.4 1.2 0.2 1.5 0.7 346 5 344 165 9.8 0 10.3 9.6 09/02/2006 21:50:00 1.5 0.3 2.3 0.7 0.5 0.2 1.1 0.4 1.6 0.2 2.3 1.1 0 2 3 165 9.9 0 10.3 9.6 09/02/2006 22:00:00 1.6 0.2 1.9 1.1 0.4 0.1 0.7 0.4 1.8 0.2 2.3 1.5 3 1 3 165 9.9 0 10.3 9.6 09/02/2006 22:10:00 1.5 0.3 2.3 0.7 0.8 0.3 1.5 0.4 1.6 0.2 1.9 1.1 343 10 355 165 9.8 0 9.8 9.6 09/02/2006 22:20:00 2.1 0.3 2.6 1.1 0.9 0.4 1.9 0.4 2.1 0.3 2.6 1.1 1 5 359 165 9.8 0 10.1 9.6 09/02/2006 22:30:00 2.6 0.3 3 1.5 1 0.3 2.3 0.4 2.5 0.4 3.4 1.1 359 4 0 165 10 0 10.1 9.6 09/02/2006 22:40:00 2.4 0.2 2.6 1.9 1.5 0.7 2.6 0.4 2.5 0.2 3 1.9 9 9 356 165 9.8 0 10.1 9.6 09/02/2006 22:50:00 2.9 0.4 3.8 2.3 2.5 0.4 3.4 1.5 3 0.4 3.8 2.3 19 3 14 165 10.1 0.1 10.3 9.6 09/02/2006 23:00:00 3.7 0.3 4.2 3 3.4 0.5 4.2 2.3 3.8 0.4 4.6 2.6 19 3 19 165 10.1 0.1 10.3 9.8 09/02/2006 23:10:00 3.6 0.3 4.2 3 3.2 0.3 4.2 2.3 3.7 0.2 4.2 3 19 2 16 165 10.1 0.1 10.3 9.8 09/02/2006 23:20:00 3.1 0.3 4.2 2.6 2.8 0.4 3.8 1.9 3.4 0.3 4.2 2.6 18 3 24 165 10.1 0 10.3 9.8 09/02/2006 23:30:00 3 0.2 3.4 2.6 2.8 0.4 3.4 1.5 3.1 0.2 3.8 2.6 20 5 19 165 10.2 0 10.6 10.1 09/02/2006 23:40:00 3.5 0.4 4.2 2.6 3.5 0.4 4.2 2.6 3.5 0.5 4.6 2.3 31 5 39 165 10.2 0 10.3 10.1 09/02/2006 23:50:00 4 0.6 4.9 2.6 3.7 0.8 5.3 1.1 4 0.5 5.3 3 20 6 25 165 10.1 0 10.3 9.8 09/03/2006 00:00:00 4.5 0.4 5.3 3.4 3 0.7 4.9 1.5 4.3 0.5 5.7 3 8 5 15 165 10.1 0 10.3 9.6 09/03/2006 00:10:00 4.9 0.5 5.7 3.4 3.6 0.7 5.3 1.5 4.8 0.6 6.1 3.4 11 4 13 165 10.1 0 10.3 9.8 09/03/2006 00:20:00 4.7 0.3 5.7 3.8 3.1 0.7 4.9 1.9 4.6 0.4 5.3 3.4 9 4 16 165 10.1 0 10.3 9.8 09/03/2006 00:30:00 4.6 0.4 5.7 3.8 2.4 0.5 4.6 1.5 4.6 0.4 5.7 3.8 4 4 5 165 10 0 10.3 9.6 09/03/2006 00:40:00 4.7 0.5 5.7 3 2.8 0.7 4.6 1.1 4.7 0.4 5.7 3.8 7 5 10 165 10 0 10.3 9.6 09/03/2006 00:50:00 4.4 0.4 5.7 3.4 2.5 0.6 4.6 1.1 4.4 0.4 5.3 3.4 1 6 9 165 10 0 10.3 9.6 09/03/2006 01:00:00 4.2 0.3 4.9 3.4 2.8 0.8 4.9 1.5 4.2 0.3 4.9 3.8 355 5 358 165 10 0 10.3 9.6 09/03/2006 01:10:00 4.3 0.3 4.9 3.4 3 0.7 4.9 1.5 4.4 0.3 5.3 3.4 355 5 352 165 10 0 10.3 9.6 09/03/2006 01:20:00 4.6 0.3 5.3 3.8 3 0.7 4.9 1.5 4.7 0.3 5.7 3.8 357 4 354 165 10 0 10.3 9.6 09/03/2006 01:30:00 4.8 0.4 6.1 4.2 2.8 0.6 4.6 1.5 4.9 0.4 6.5 4.2 359 5 0 165 10 0 10.3 9.6 09/03/2006 01:40:00 4.8 0.4 5.7 4.2 3.3 0.8 4.9 1.9 4.9 0.4 6.1 3.8 356 6 358 165 10 0.2 10.3 9.6 09/03/2006 01:50:00 4.9 0.5 6.1 3.8 3.2 0.7 5.3 1.9 5 0.5 6.1 3.8 358 6 358 165 10 0.2 10.3 9.6 09/03/2006 02:00:00 4.7 0.5 5.7 3.4 3.5 0.8 5.3 1.5 4.8 0.4 5.7 3.8 354 4 356 165 10 0.1 10.3 9.6 09/03/2006 02:10:00 4.7 0.5 5.7 3.4 3.8 0.8 5.7 1.9 4.7 0.5 5.7 3.4 351 6 356 165 9.8 0 10.1 9.3 09/03/2006 02:20:00 5.4 0.5 6.8 4.2 5.2 0.6 6.8 3.4 5.3 0.5 6.5 3.8 345 6 352 165 9.8 0 10.1 9.3 09/03/2006 02:30:00 5.8 0.6 7.2 4.2 5.8 0.7 7.6 3.8 5.7 0.6 7.2 4.2 340 6 338 165 10 0.1 10.3 9.3 09/03/2006 02:40:00 5.3 0.5 6.8 3.8 5.2 0.6 6.8 3.8 5.2 0.5 7.2 3.8 343 6 336 165 10 0.1 10.3 9.3 09/03/2006 02:50:00 5.6 0.7 7.2 3.8 5 0.8 6.8 2.6 5.4 0.7 7.2 3.4 349 5 352 165 10 0.1 10.3 9.6 09/03/2006 03:00:00 4.5 0.5 5.3 3 3.8 1 5.7 1.5 4.4 0.4 5.3 3.4 351 7 345 165 10 0.1 10.3 9.6 09/03/2006 03:10:00 3.7 0.5 4.9 2.3 2.7 0.7 4.9 1.1 3.7 0.5 4.9 2.3 358 8 354 165 10 0.1 10.3 9.6 09/03/2006 03:20:00 3 0.5 4.6 1.9 2.3 0.7 4.2 0.7 3 0.5 4.6 1.9 11 9 354 165 10 0 10.3 9.6 09/03/2006 03:30:00 3.5 0.4 4.6 2.6 2.6 0.9 4.6 1.1 3.5 0.5 4.6 2.3 6 13 28 165 10 0 10.3 9.6 09/03/2006 03:40:00 4.6 1.1 7.6 2.6 3.3 1.3 7.2 1.1 4.5 0.9 6.8 2.6 7 8 10 165 9.9 0 10.1 9.6 09/03/2006 03:50:00 6.2 0.7 8 4.6 4.3 1 7.6 2.6 6 0.7 8.4 4.2 7 6 14 165 10 0 10.3 9.6 09/03/2006 04:00:00 6.1 0.7 7.6 4.2 5.2 0.9 7.2 3 5.9 0.8 7.6 3.8 13 7 13 165 10 0 10.3 9.6 09/03/2006 04:10:00 5.5 0.6 7.2 3.8 3.9 0.7 6.1 2.3 5.2 0.6 6.5 3.4 7 6 10 165 10 0 10.3 9.6 09/03/2006 04:20:00 4.6 0.9 6.1 2.6 3.2 0.7 5.3 1.5 4.5 0.8 6.1 2.6 358 8 6 165 10 0 10.3 9.6 09/03/2006 04:30:00 4.2 0.7 6.1 2.6 3 0.6 4.9 1.5 4.1 0.7 6.1 2.6 355 8 357 165 10 0 10.3 9.6 09/03/2006 04:40:00 5.5 0.9 8 3 4.1 1.3 8 2.3 5 0.8 7.6 3.4 5 9 18 165 10.1 0.1 10.3 9.6 09/03/2006 04:50:00 7 0.7 8.4 4.9 5.5 1.2 8.4 2.6 6.8 0.8 8.8 4.6 9 7 6 165 10.2 0 10.3 9.6 09/03/2006 05:00:00 7.1 1 9.1 4.9 6.2 1.3 9.1 2.6 6.9 1 9.5 4.6 14 7 19 165 10.3 0 10.6 9.8 09/03/2006 05:10:00 6.9 0.8 9.1 5.3 5.6 1.2 8.8 2.6 6.9 0.9 9.1 4.2 12 6 10 165 10.3 0 10.9 9.8 09/03/2006 05:20:00 7.8 0.7 9.5 5.7 6.1 1.1 8.8 3 7.7 0.8 9.9 5.3 10 5 6 165 10.3 0 10.6 9.8 09/03/2006 05:30:00 7.9 0.8 10.3 5.7 5.7 1.5 9.9 3 7.7 0.9 10.3 6.1 5 8 16 165 10.3 0 10.6 9.8 09/03/2006 05:40:00 7.6 0.7 9.5 5.7 5.2 1.2 8 3 7.5 0.7 9.9 5.7 4 6 7 165 10.3 0 10.9 9.8 09/03/2006 05:50:00 8.4 0.7 9.9 6.5 6.3 1.3 9.1 3.4 8.3 0.8 9.9 5.3 8 6 16 165 10.3 0 10.6 9.8 09/03/2006 06:00:00 7.3 0.8 9.1 4.2 5 1.1 8.8 3 7.1 0.7 8.8 5.3 4 7 16 165 10.3 0 10.6 9.8 09/03/2006 06:10:00 7.3 0.9 9.5 4.9 5.1 1.5 9.1 2.6 7.1 0.8 9.5 5.3 2 7 9 165 10.2 0.1 10.6 9.6 09/03/2006 06:20:00 6.6 0.9 9.1 4.9 5 1.4 9.9 3 6.4 0.8 9.1 4.6 2 10 348 165 10.3 0.1 10.6 9.8 09/03/2006 06:30:00 7.3 1 9.1 4.2 5.3 1.2 9.1 2.6 7.1 1 8.8 4.6 7 9 23 165 10.3 0 10.6 9.8 09/03/2006 06:40:00 7.2 0.9 9.5 4.9 5.5 1.3 9.1 2.6 7.1 0.8 9.1 4.6 10 6 22 165 10.3 0 10.6 9.8 09/03/2006 06:50:00 7.3 0.8 9.1 4.9 5.3 1.2 8.4 3 7.1 0.8 9.1 4.9 8 7 23 165 10.4 0 10.9 10.1 09/03/2006 07:00:00 7.2 0.8 9.5 5.7 5.3 1.3 8.4 2.6 7.1 0.9 9.9 5.3 8 6 9 165 10.4 0 10.6 10.1 09/03/2006 07:10:00 7.3 0.9 9.5 4.9 5.4 1.4 9.1 2.6 7.1 0.9 9.5 4.6 8 7 10 165 10.4 0 10.9 10.1 09/03/2006 07:20:00 8.4 0.7 9.9 6.1 6 1.3 9.5 3.4 8.1 0.8 9.9 5.3 3 8 6 165 10.5 0.1 10.9 10.3 09/03/2006 07:30:00 6.4 1 8.8 4.6 4.6 1.6 9.1 2.3 6.3 1 8.8 4.2 6 9 21 165 10.6 0.2 10.9 10.3 09/03/2006 07:40:00 6.9 0.7 9.1 5.3 5.2 1.2 8.4 2.6 6.8 0.7 8.8 4.9 10 7 11 165 10.7 0.2 10.9 10.3 09/03/2006 07:50:00 6.9 0.7 8.8 4.6 4.9 1 7.2 3 6.7 0.9 8.8 4.2 6 8 4 165 10.6 0.2 10.9 10.3 09/03/2006 08:00:00 7.1 0.8 9.9 5.3 4.7 1.2 8.4 2.6 7 0.7 8.8 5.3 3 8 4 165 10.7 0.1 11.1 10.3 09/03/2006 08:10:00 5.6 0.8 7.6 3.4 4.9 1.1 7.6 2.3 5.4 0.9 7.6 3.8 350 8 351 165 11 0 11.4 10.6 09/03/2006 08:20:00 5.3 0.5 6.8 3.8 3.7 1 7.2 1.9 5.2 0.5 6.8 4.2 359 7 350 165 11.1 0 11.4 10.9 09/03/2006 08:30:00 5.5 0.5 6.8 3.8 4.3 0.9 6.1 2.6 5.5 0.5 6.8 4.2 11 6 3 165 11.3 0 11.4 11.1 09/03/2006 08:40:00 6 0.6 7.2 4.2 4.5 1.2 7.2 2.3 5.7 0.6 7.2 3.8 355 7 356 165 11.3 0 11.4 10.9 09/03/2006 08:50:00 5.4 0.7 7.6 3.8 4.3 1.2 6.8 2.3 5 0.7 7.2 3 354 8 359 165 11.3 0 11.7 11.1 09/03/2006 09:00:00 5.8 1.1 9.1 3.8 4.4 1.4 8.8 1.9 5.8 1.2 9.5 3.4 355 8 354 165 11.4 0 11.7 11.1 09/03/2006 09:10:00 7.1 0.9 9.1 4.9 5.3 1.3 8.4 2.6 6.8 0.9 9.1 3.8 357 6 356 165 11.5 0.3 11.9 11.1 09/03/2006 09:20:00 7 0.7 8.8 4.9 5.4 1.2 8.4 3 6.7 0.8 8.8 4.9 356 6 354 165 11.9 0.2 12.2 11.4 09/03/2006 09:30:00 6.1 0.8 8.4 3.8 4.4 1 8.4 2.6 6.1 0.8 8.4 4.2 0 7 5 165 11.8 0.2 12.2 11.4 09/03/2006 09:40:00 6.2 1.2 9.1 3.8 4.4 1 7.6 2.3 5.9 1.1 9.1 3.8 357 8 349 165 11.8 0.1 12.2 11.4 09/03/2006 09:50:00 6.3 0.7 8.4 4.6 5.2 1.1 7.6 2.6 6.2 0.6 8.4 4.6 2 14 13 165 12.3 0.1 12.7 11.9 09/03/2006 10:00:00 7.2 1.1 9.9 3.8 5.8 1.5 9.9 3 7 1.3 10.7 3.8 2 12 28 165 13.3 0.5 14.1 12.5 09/03/2006 10:10:00 7.3 1 9.9 4.9 5.9 1.5 10.3 3 7.1 1 9.5 4.6 6 11 15 165 13.7 0.3 14.4 13 09/03/2006 10:20:00 7.3 1.1 10.3 4.9 5.6 1.2 9.1 2.6 7.2 1.1 10.3 4.9 4 11 2 165 13.6 0.3 14.1 12.7 09/03/2006 10:30:00 7.5 0.9 9.5 4.9 5.6 1.2 8.8 3.4 7.4 1 9.9 4.9 8 8 5 165 12.3 0.3 13 11.7 09/03/2006 10:40:00 6.5 1.2 9.9 3.8 5.1 1 8 3 6.4 1.3 9.9 3.8 9 9 4 165 11.7 0 11.9 11.7 09/03/2006 10:50:00 7 0.8 9.1 5.3 5.9 1.3 8.8 2.6 7 1 9.5 4.6 13 7 18 165 11.3 0.1 11.7 11.1 09/03/2006 11:00:00 6.2 0.7 8.4 4.2 5 1.1 8.4 2.6 6.2 0.7 8.4 4.6 11 6 20 165 11.5 0 11.7 11.4 09/03/2006 11:10:00 6.5 0.5 7.6 4.9 5.5 0.9 7.2 2.6 6.5 0.5 8 5.3 13 5 15 165 11.1 0.1 11.7 10.9 09/03/2006 11:20:00 5.6 0.5 7.2 4.6 4.1 1.1 6.5 1.9 5.6 0.5 7.2 4.6 10 6 12 165 10.9 0 11.1 10.9 09/03/2006 11:30:00 6.3 0.5 7.6 4.9 3.9 0.7 6.1 2.3 6.3 0.6 8 4.9 5 4 6 165 11.3 0.2 11.9 10.9 09/03/2006 11:40:00 6.8 0.7 9.1 4.9 4.7 1 8.4 2.6 6.7 0.8 9.5 4.9 3 7 10 165 12 0 12.2 11.7 09/03/2006 11:50:00 6.4 0.7 8.8 4.6 4.7 1.1 7.6 2.6 6.4 0.8 9.5 4.6 8 6 5 165 11.9 0 12.2 11.9 09/03/2006 12:00:00 7.5 0.7 9.9 5.3 6.1 1.4 9.5 3.4 7.6 0.8 9.9 5.7 12 8 16 165 12.1 0 12.2 11.9 09/03/2006 12:10:00 7.8 0.7 9.5 5.7 6.5 1.3 9.1 3.4 7.7 0.8 9.9 5.7 13 6 16 165 12.2 0 12.5 11.9 09/03/2006 12:20:00 7.1 1.1 9.5 3.8 6.1 1.5 9.1 3 7.1 1.1 9.1 3.8 13 9 12 165 12.3 0 12.5 12.2 09/03/2006 12:30:00 6.4 0.7 9.1 4.9 5.3 1 7.6 2.3 6.4 0.7 8.4 4.6 10 7 6 165 12.5 0 12.7 12.2 09/03/2006 12:40:00 6.9 0.9 8.8 4.6 6.1 1.1 8.4 3.4 7 0.8 9.1 4.6 15 8 6 165 12.6 0 12.7 12.5 09/03/2006 12:50:00 7.2 0.9 9.1 4.9 5.9 1.1 8.4 3.4 7.2 0.9 9.9 4.2 11 8 13 165 12.5 0 13 12.2 09/03/2006 13:00:00 6.8 0.8 8.8 4.2 6.1 1 8.8 3.8 6.7 0.9 8.8 4.2 17 9 29 165 12.8 0 13 12.5 09/03/2006 13:10:00 6.2 1 9.5 3.4 5.9 1 9.5 3.4 6.3 1 9.1 3.8 19 10 21 165 12.9 0 13 12.5 09/03/2006 13:20:00 6.1 0.7 8 4.2 6 0.8 8 2.6 6.2 0.8 8.8 4.6 26 9 24 165 12.8 0 13 12.2 09/03/2006 13:30:00 6.3 1 8.8 3.4 6.2 1.1 8.8 3.4 6.4 1 8.8 3.8 24 8 23 165 12.7 0 13 12.5 09/03/2006 13:40:00 6 1 8 3.4 5.9 1 8 3.4 5.9 0.9 8.4 3.8 27 9 31 165 12.7 0 13 12.2 09/03/2006 13:50:00 6.8 0.6 8.4 4.2 6.6 0.8 8 3.8 6.8 0.6 8.4 5.3 21 7 22 165 12.5 0.1 13 12.2 09/03/2006 14:00:00 6.3 0.6 7.6 4.2 5.9 0.8 7.2 3.4 6.3 0.6 7.6 4.6 17 6 13 165 12.3 0 12.5 11.9 09/03/2006 14:10:00 6.1 0.6 7.6 4.6 5.8 0.8 7.2 3.4 6.1 0.7 7.6 4.6 20 7 19 165 12.6 0.2 13.3 12.2 09/03/2006 14:20:00 6.1 0.8 7.6 3 5.9 0.8 7.6 3.4 6.3 0.8 8 3.8 23 9 21 165 13.5 0.3 13.8 12.7 09/03/2006 14:30:00 5.9 0.8 7.6 3.8 5.9 0.9 7.6 2.6 5.9 0.8 7.6 3.8 25 8 18 165 12.5 0.4 13 11.4 09/03/2006 14:40:00 5.7 0.9 7.2 3.4 5.6 0.9 7.2 3 5.6 1 7.2 3 27 7 31 165 11.7 0 11.9 11.4 09/03/2006 14:50:00 5.7 0.8 7.6 3.8 5.5 0.8 7.6 3.4 5.8 0.8 7.6 3.4 23 8 29 165 12.5 0.6 13.5 11.7 09/03/2006 15:00:00 5.8 0.8 7.6 3.8 5.7 0.8 7.6 3.8 5.9 0.9 7.6 3 28 10 29 165 13.7 0.3 14.4 13 09/03/2006 15:10:00 5.7 0.8 7.6 4.2 5.6 0.9 7.6 3.4 5.7 0.9 8.4 3.4 27 11 19 165 13.5 0.2 14.4 13 09/03/2006 15:20:00 7 0.9 9.1 4.6 6.8 1 8.8 4.2 6.8 1 8.8 4.2 27 8 24 165 13.1 0.2 13.5 12.7 09/03/2006 15:30:00 7.4 1 9.5 4.9 7.2 1.1 9.5 4.2 7.5 1 9.5 4.9 24 8 36 165 12.7 0.2 13 12.2 09/03/2006 15:40:00 7.3 0.8 9.9 5.3 7.2 0.8 9.5 4.9 7.2 0.8 9.1 5.3 23 7 26 165 12.8 0.1 13 12.5 09/03/2006 15:50:00 7.4 1 9.5 4.6 7.2 1 9.5 4.2 7.4 1 9.5 4.6 25 8 30 165 13.1 0.2 13.5 12.5 09/03/2006 16:00:00 6.9 0.7 8.8 4.6 6.8 0.8 8.4 3.4 7.1 0.8 9.1 4.6 23 7 22 165 12.7 0.2 13 11.9 09/03/2006 16:10:00 7.7 0.6 9.5 5.7 7.5 0.8 8.8 3.8 7.5 0.7 9.5 4.9 21 6 23 165 11.9 0.2 12.5 11.7 09/03/2006 16:20:00 6.5 0.6 8 4.6 6.3 0.8 8 3.8 6.6 0.7 8.4 4.6 20 6 19 165 11.8 0 11.9 11.7 09/03/2006 16:30:00 6.3 0.6 7.6 4.6 6.1 0.8 7.6 3.4 6.3 0.7 8 4.6 20 6 19 165 11.5 0 11.9 11.4 09/03/2006 16:40:00 5.9 0.6 8 4.2 5.4 1 8 2.6 6 0.7 7.6 4.2 17 8 29 165 11.5 0 11.7 11.4 09/03/2006 16:50:00 6.1 0.6 7.2 3.8 6 0.7 7.6 3.4 6 0.7 7.6 3.8 23 8 22 165 11.3 0 11.7 11.1 09/03/2006 17:00:00 6.8 0.4 7.6 5.3 6.9 0.5 8 5.3 6.5 0.6 7.6 4.6 29 4 32 165 11.1 0 11.4 10.9 09/03/2006 17:10:00 6.6 0.7 8 4.2 6.7 0.8 8 4.2 6.5 0.7 8 4.9 26 5 27 165 11 0 11.1 10.9 09/03/2006 17:20:00 7.3 0.5 8.4 5.3 7.3 0.5 8.4 5.3 7.1 0.7 8.4 4.6 24 4 12 165 11.1 0 11.4 10.9 09/03/2006 17:30:00 7 0.7 8.4 4.6 7 0.7 8.4 4.6 6.8 0.7 8.4 4.6 25 6 33 165 11 0 11.4 10.9 09/03/2006 17:40:00 7.4 0.8 8.8 4.6 7.4 0.9 8.8 4.6 7.1 0.9 9.1 4.9 24 5 25 165 10.9 0 11.4 10.9 09/03/2006 17:50:00 7.3 0.9 9.1 4.2 7.2 1 9.1 4.2 7.2 0.8 8.8 4.9 25 7 19 165 10.9 0.1 11.4 10.6 09/03/2006 18:00:00 7.2 0.7 8.8 4.9 6.9 0.8 8.4 4.2 7.1 0.7 8.4 4.9 21 6 25 165 10.7 0.1 11.1 10.3 09/03/2006 18:10:00 6.9 0.5 8 5.3 6.2 0.9 8 3.4 6.9 0.6 8 5.3 16 5 15 165 10.6 0.2 11.4 10.3 09/03/2006 18:20:00 6.8 0.7 8.8 4.6 6.4 0.9 8.4 3.8 6.8 0.7 9.1 4.9 18 6 22 165 10.5 0.2 10.9 10.1 09/03/2006 18:30:00 7 0.5 8.8 5.7 6.6 0.7 8 4.2 6.9 0.6 8.4 4.9 17 5 19 165 10.4 0.2 10.9 10.1 09/03/2006 18:40:00 7 0.5 8.8 5.3 6.4 0.8 8 3 6.9 0.6 8.4 5.7 16 5 12 165 10.5 0.2 10.9 10.1 09/03/2006 18:50:00 7.5 0.6 9.1 5.3 7 0.9 9.1 3.8 7.6 0.6 9.1 5.3 17 5 23 165 10.5 0.1 10.9 10.3 09/03/2006 19:00:00 7.9 0.4 8.8 5.7 7.5 0.7 8.8 4.6 7.8 0.6 8.8 6.1 18 3 20 165 10.4 0 10.6 10.1 09/03/2006 19:10:00 7.8 0.6 9.1 5.7 7.4 0.8 8.8 4.6 7.7 0.6 9.1 6.1 18 5 15 165 10.5 0 10.6 10.3 09/03/2006 19:20:00 7.1 0.7 8.8 5.3 6.5 1 8.4 3.4 7.1 0.8 8.8 4.9 16 5 22 165 10.4 0 10.6 9.8 09/03/2006 19:30:00 6.7 0.7 8 4.9 6 0.9 8 3 6.8 0.6 8 4.6 15 5 10 165 10.3 0 10.6 10.3 09/03/2006 19:40:00 6.8 0.6 8 4.9 5.7 1 8.4 3.4 6.7 0.7 8.4 4.9 13 6 17 165 10.3 0 10.6 10.3 09/03/2006 19:50:00 6.6 0.5 7.6 4.9 5.1 0.9 7.2 3 6.3 0.5 7.6 4.9 11 4 16 165 10.2 0 10.6 10.1 09/03/2006 20:00:00 6.5 0.4 7.6 5.3 5.7 0.7 7.2 3.4 6.2 0.6 7.6 4.6 14 4 22 165 10.2 0 10.6 9.8 09/03/2006 20:10:00 6.6 0.6 8.8 5.3 5.3 1 8.4 3 6.4 0.7 8.4 4.9 12 5 17 165 10.3 0 10.6 9.8 09/03/2006 20:20:00 6.7 0.5 7.6 4.9 6 0.9 7.6 3 6.7 0.5 7.6 4.9 16 5 14 165 10.3 0 10.6 10.1 09/03/2006 20:30:00 7 0.4 8.4 5.7 6.6 0.6 8 4.6 6.9 0.6 8.4 4.9 18 3 12 165 10.3 0 10.9 10.1 09/03/2006 20:40:00 6.7 1 9.5 4.6 5.9 1.2 8.8 3 6.4 1 9.5 4.2 15 7 16 165 10.3 0 10.6 9.8 09/03/2006 20:50:00 6.3 0.8 8.4 4.2 6 0.8 8 3.8 6.1 0.9 8.4 4.2 22 8 9 165 10.3 0 10.6 9.8 09/03/2006 21:00:00 5.9 0.8 8.4 3.8 5.8 0.9 8.8 3.4 5.7 0.8 8 3.8 23 5 27 165 10.2 0 10.6 9.8 09/03/2006 21:10:00 5.3 0.7 6.8 3.4 5.2 0.8 6.5 2.6 5.1 0.7 6.8 3.4 25 6 28 165 10.2 0 10.9 9.8 09/03/2006 21:20:00 5.6 0.9 8.8 3.8 5.5 1 8.8 3.4 5.3 1 8.8 3 31 8 29 165 10.3 0 10.6 10.1 09/03/2006 21:30:00 6.3 0.9 8.4 3.8 6.1 1 8.4 3.4 6.2 1 8.4 4.2 25 8 30 165 10.5 0.1 10.9 10.3 09/03/2006 21:40:00 6.4 0.7 8.4 4.2 6 1 8.4 2.6 6 0.8 8 3.4 20 7 23 165 10.5 0.1 10.9 10.3 09/03/2006 21:50:00 6.8 0.7 9.1 4.6 6.6 0.8 9.1 4.6 6.4 0.8 8.4 4.6 25 7 28 165 10.5 0 10.9 10.3 09/03/2006 22:00:00 6.2 0.9 8.8 4.6 5.6 1 8 3.4 6.1 0.8 8.4 3.8 16 8 21 165 10.5 0 10.6 10.3 09/03/2006 22:10:00 6 0.9 8.8 4.2 5.3 1.1 8.8 2.6 5.7 0.8 8.4 3.8 15 9 25 165 10.5 0 10.9 10.3 09/03/2006 22:20:00 6.4 0.7 8 4.2 5.1 0.9 7.6 2.6 6.3 0.8 8.4 4.2 10 7 10 165 10.5 0 10.6 10.3 09/03/2006 22:30:00 7.5 0.8 9.1 4.6 5.7 1 8 3.4 7.3 0.9 9.5 4.9 10 6 8 165 10.5 0 10.6 10.1 09/03/2006 22:40:00 7.7 0.8 9.9 4.9 5.7 1.2 8.8 3 7.4 0.8 9.5 5.3 9 5 8 165 10.5 0 10.9 10.3 09/03/2006 22:50:00 7 0.7 8.8 5.3 5.3 1 8 3 6.6 0.7 8.4 4.9 10 6 18 165 10.4 0 10.6 10.1 09/03/2006 23:00:00 6.6 0.7 8.4 4.6 5.5 1 8 3 6.4 0.8 8 4.6 12 6 18 165 10.5 0 10.9 10.1 09/03/2006 23:10:00 6.3 0.7 7.6 4.6 5.3 1 7.6 3 6 0.7 8 4.6 13 6 11 165 10.4 0 10.9 10.1 09/03/2006 23:20:00 6.4 0.7 8 4.6 5.5 1 7.6 2.6 6 0.6 7.6 4.2 14 7 350 165 10.5 0 10.6 10.3 09/03/2006 23:30:00 6.8 0.7 8.8 4.6 5.8 1 8.4 3 6.5 0.7 8.4 4.2 13 6 20 165 10.5 0 10.9 10.1 09/03/2006 23:40:00 6.5 0.9 8.4 4.2 5.8 1.2 8 2.6 6.1 0.9 8 3.8 14 7 19 165 10.5 0 10.9 10.1 09/03/2006 23:50:00 7.2 0.8 8.8 4.6 6.4 0.8 8.4 3.8 7 0.9 8.8 4.6 15 6 8 165 10.5 0 10.9 10.1 09/04/2006 00:00:00 7.2 1 9.5 4.6 6.6 1.2 9.1 3.8 7 1 9.1 4.6 18 8 13 165 10.4 0 10.6 10.1 09/04/2006 00:10:00 7.2 0.6 8.8 5.3 5.2 0.9 7.6 3 6.9 0.6 8.4 5.3 9 6 7 165 10.3 0 10.6 9.8 09/04/2006 00:20:00 7.1 0.8 9.5 5.3 5.6 1.3 9.1 2.6 6.8 0.8 8.8 4.9 11 7 22 165 10.1 0.1 10.6 9.8 09/04/2006 00:30:00 6.5 1 9.1 3.8 5.1 1.2 8 2.6 6.2 1 8.8 3.4 9 11 2 165 10.1 0.1 10.3 9.6 09/04/2006 00:40:00 10 2.8 15.3 3 9.6 2.8 14.5 2.3 9.4 2.7 14.9 3 24 10 15 165 9.7 0.4 10.3 8.5 09/04/2006 00:50:00 10.1 1.2 12.2 6.8 9.8 1.5 12.2 4.6 9.7 1.3 12.6 6.1 23 7 26 165 8.9 0.2 9 8.3 09/04/2006 01:00:00 8.6 0.8 10.3 6.5 7.6 1.5 10.3 4.6 8.4 0.8 10.7 5.7 15 5 19 165 8.9 0 9.3 8.8 09/04/2006 01:10:00 8.4 0.9 10.3 6.5 7 1.4 10.3 3.8 8.2 0.9 10.3 5.7 11 7 21 165 9 0 9 8.8 09/04/2006 01:20:00 7.8 1.1 10.7 5.7 6.4 1.3 10.3 3.4 7.6 1.2 11.1 5.3 11 8 19 165 9.1 0 9.3 8.8 09/04/2006 01:30:00 8.4 1.2 11.5 5.7 7.2 1.3 10.7 4.2 8 1.3 11.1 5.3 12 9 7 165 9.4 0 9.6 8.8 09/04/2006 01:40:00 6.7 1.3 9.9 4.2 5.9 1.2 9.1 3 6.4 1.2 9.5 4.2 15 10 1 165 9.6 0.1 10.1 8.8 09/04/2006 01:50:00 6.4 1.2 9.5 3.8 6 1.3 9.5 3.4 6 1.3 10.3 3.4 21 11 17 165 9.6 0.1 9.8 9 09/04/2006 02:00:00 6.1 1.1 8.8 3.4 5.8 1 8.8 3.4 5.8 1 8.8 3.8 26 10 25 165 9.8 0 10.3 9.3 09/04/2006 02:10:00 5.5 1.3 8.4 2.6 5.3 1.2 8.4 2.6 5 1.3 8.8 1.9 36 12 37 165 9.8 0.1 9.8 9.3 09/04/2006 02:20:00 6.2 1.2 11.5 3 6.3 1.3 11.1 3 6 1.2 9.9 1.9 56 11 61 165 9.6 0.2 9.8 8.8 09/04/2006 02:30:00 7 1.2 9.5 3.8 6.9 1.2 9.9 3.8 6.5 1.1 9.5 3.8 44 11 48 165 9.6 0.1 9.8 9 09/04/2006 02:40:00 5.4 1.1 8.8 2.6 5.4 1.2 8.8 2.6 5.3 1.1 9.5 2.6 43 11 57 165 9.8 0 10.3 9 09/04/2006 02:50:00 4.2 1 8 1.9 4.1 1 7.6 1.5 4.1 1 7.6 1.9 37 13 18 165 9.8 0 9.8 9 09/04/2006 03:00:00 4.4 0.7 6.1 2.6 4.4 0.7 6.1 2.6 4.3 0.7 5.7 2.3 49 9 66 165 9.8 0 10.1 9 09/04/2006 03:10:00 5.4 1.2 8 3.4 5.2 1.2 7.6 2.6 5.1 1.2 8 2.6 29 11 21 165 9.7 0.1 10.6 9 09/04/2006 03:20:00 5.8 1.1 8 3.4 5.6 1.1 8 2.6 5.5 1 8.4 3 28 8 24 165 9.6 0.1 9.8 9 09/04/2006 03:30:00 4.5 0.9 8 2.6 4.4 0.8 7.2 2.3 4.2 0.8 6.5 2.6 43 11 36 165 9.8 0 9.8 9 09/04/2006 03:40:00 4.5 1 6.5 2.3 4.5 1 6.5 2.3 4.4 1 6.5 2.3 51 9 67 165 9.8 0.1 9.8 9 09/04/2006 03:50:00 4.5 0.9 6.5 2.3 4.5 0.9 6.8 2.3 4.4 0.9 6.5 2.3 47 10 62 165 9.7 0.2 9.8 9 09/04/2006 04:00:00 4.5 1.6 8.8 1.9 4.5 1.7 9.5 1.9 4.3 1.5 8.8 1.5 47 23 63 165 9.6 0 9.8 9 09/04/2006 04:10:00 5.5 1.4 8.8 2.6 5.5 1.5 9.1 2.6 5.2 1.3 8.8 2.3 46 11 47 165 9.6 0.1 9.8 9 09/04/2006 04:20:00 4.8 1.2 8.8 2.6 4.8 1.2 8.8 2.6 4.6 1.1 7.6 1.9 59 13 58 165 9.6 0.1 9.8 8.8 09/04/2006 04:30:00 6.5 1.1 8.4 3.8 6.6 1.1 8.8 3.8 6.2 1.1 8.4 3.8 56 8 64 165 9.6 0.1 10.1 9 09/04/2006 04:40:00 5.1 1 7.2 2.6 5.2 1 7.2 2.6 5.1 0.9 7.2 3 54 18 53 165 9.6 0.1 9.8 9 09/04/2006 04:50:00 5.4 1.1 8.4 3 5 1.1 8 2.6 5.4 1 8.4 3 19 8 21 165 9.6 0.1 10.3 9 09/04/2006 05:00:00 5.3 1.3 8 2.6 5 1.3 7.6 2.3 5.1 1.3 7.6 2.3 24 10 25 165 9.6 0 9.6 9.6 09/04/2006 05:10:00 4 0.8 6.1 1.9 3.9 0.8 6.1 1.9 4 0.8 6.5 1.9 39 17 25 165 9.6 0 9.6 9 09/04/2006 05:20:00 5.9 1.7 9.5 2.6 5.6 1.7 9.1 2.6 5.4 1.6 9.1 2.3 27 12 19 165 9.6 0.1 9.6 8.8 09/04/2006 05:30:00 7 0.9 9.1 4.6 6.1 1.1 8.8 3.4 6.7 1 9.1 4.6 15 7 18 165 9.6 0 10.1 9.3 09/04/2006 05:40:00 6.7 0.7 8.8 4.6 5.6 0.9 7.6 3.4 6.4 0.7 8.4 4.6 14 7 12 165 9.5 0 9.6 9.3 09/04/2006 05:50:00 6.4 0.8 8.4 3.8 5.3 1 8.4 2.3 6.1 0.8 8.4 3.8 12 7 12 165 9.5 0 9.6 9.3 09/04/2006 06:00:00 6.8 0.7 8 4.2 5.8 0.9 8 3.4 6.5 0.7 8 3.8 14 6 22 165 9.4 0 9.6 9 09/04/2006 06:10:00 6.6 0.7 8.4 4.2 5.4 1 7.6 3 6.6 0.8 8.8 4.6 13 7 16 165 9.4 0 9.6 9 09/04/2006 06:20:00 6.7 0.7 8 4.6 5.1 0.9 7.2 3 6.6 0.7 8.4 4.6 11 5 12 165 9.2 0 9.3 9 09/04/2006 06:30:00 6.4 0.5 7.6 4.9 5.1 0.8 7.2 3 6.3 0.6 7.6 4.2 13 4 13 165 9.1 0 9.3 9 09/04/2006 06:40:00 6.2 0.9 8.8 4.2 4.9 1.2 8.4 2.6 6.1 1 8.8 4.2 12 6 14 165 9.2 0 9.3 9 09/04/2006 06:50:00 5.9 0.5 7.2 4.6 4.4 1 6.8 1.9 5.9 0.5 7.6 4.6 11 5 17 165 9.3 0 9.6 9 09/04/2006 07:00:00 5.4 0.7 7.2 3.8 4.6 1.1 6.8 2.3 5.4 0.7 6.8 3.4 15 7 14 165 9.2 0 9.3 9 09/04/2006 07:10:00 5.1 1.1 7.2 2.3 4.3 1.2 6.8 1.1 5.1 0.9 7.2 3 15 6 15 165 9.2 0 9.3 9 09/04/2006 07:20:00 4.9 0.5 6.1 3.8 4 0.6 5.7 2.3 4.8 0.5 6.1 3.4 14 4 16 165 9.3 0 9.6 9 09/04/2006 07:30:00 3.9 0.4 4.9 3 3.1 0.6 4.6 1.5 3.9 0.4 5.3 2.6 13 5 357 165 9.4 0 9.6 9 09/04/2006 07:40:00 4.9 0.7 6.5 3.4 3.5 0.9 5.7 1.5 4.9 0.6 6.5 3.4 10 9 1 165 9.5 0 9.6 9.3 09/04/2006 07:50:00 5.3 0.5 6.8 4.2 4.1 0.9 6.1 2.3 5.3 0.5 6.5 3.8 13 5 16 165 9.8 0.2 10.3 9.3 09/04/2006 08:00:00 5.3 0.5 6.5 3.8 3.9 0.7 5.3 1.9 5.3 0.5 6.5 3.8 11 3 11 165 9.6 0.1 9.8 9 09/04/2006 08:10:00 4.3 0.4 5.3 3 3.2 0.7 4.6 1.5 4.3 0.5 5.3 3 11 6 13 165 9.7 0 9.8 9.3 09/04/2006 08:20:00 4.1 0.5 5.3 2.6 2.9 0.9 4.9 1.1 4 0.5 5.3 3 8 8 7 165 9.8 0 10.1 9.3 09/04/2006 08:30:00 4.6 0.5 5.7 3 3.3 0.8 5.3 1.1 4.7 0.5 6.1 3.4 11 6 18 165 10.1 0.1 10.3 9.6 09/04/2006 08:40:00 4.3 0.6 5.7 2.6 3.8 0.7 4.9 1.9 4.3 0.7 5.7 2.6 18 5 20 165 10.4 0 10.9 9.8 09/04/2006 08:50:00 4.4 0.6 5.7 3 4.3 0.6 5.7 2.3 4.5 0.6 6.1 3 23 5 27 165 10.2 0.1 10.6 9.6 09/04/2006 09:00:00 4.4 0.4 5.7 3.4 3.9 0.6 5.3 1.9 4.4 0.4 5.3 3.4 19 7 28 165 10.1 0 10.3 9.6 09/04/2006 09:10:00 3.7 0.5 4.9 2.3 2.3 0.6 3.8 0.7 3.8 0.5 5.3 2.3 2 7 2 165 10.7 0.1 11.1 10.1 09/04/2006 09:20:00 3.3 0.6 4.9 1.9 2.8 0.6 4.2 1.1 3.3 0.6 5.3 1.9 351 12 357 165 10.8 0.1 11.1 10.3 09/04/2006 09:30:00 2.9 0.4 4.2 1.9 2.5 0.5 3.8 1.1 2.9 0.5 4.2 1.9 15 13 7 165 10.8 0.1 11.1 10.3 09/04/2006 09:40:00 3 0.5 4.2 1.5 2 0.6 3.8 0.7 3 0.6 4.6 1.5 9 11 6 165 11.3 0.5 12.5 10.3 09/04/2006 09:50:00 3.6 0.5 5.3 2.6 2.2 0.6 3.8 0.7 3.9 0.5 5.7 2.6 4 8 358 165 12.1 0 12.5 11.9 09/04/2006 10:00:00 3.4 0.5 4.6 2.3 2.4 0.9 4.6 0.7 3.6 0.5 4.6 2.3 355 9 334 165 12.2 0.2 12.5 11.7 09/04/2006 10:10:00 2.4 0.7 3.8 0.4 1.9 0.8 3.8 0.4 2.5 0.7 4.2 0.4 18 18 359 165 11.7 0 12.2 11.4 09/04/2006 10:20:00 2.4 0.9 4.2 0.4 2.2 1 4.2 0.4 2.5 0.9 4.6 0.4 47 29 42 165 11.3 0 11.7 10.9 09/04/2006 10:30:00 2.7 0.5 3.8 0.7 2.7 0.5 3.8 0.7 2.8 0.6 4.2 0.4 44 14 26 165 11.3 0.1 11.4 10.9 09/04/2006 10:40:00 2.9 0.5 3.8 1.5 2.5 0.6 3.8 0.7 2.8 0.4 3.8 1.9 4 22 29 165 12 0.4 12.7 11.1 09/04/2006 10:50:00 2.6 0.6 4.2 1.1 1.8 0.6 3.4 0.4 2.7 0.6 4.6 1.5 351 12 358 165 13.1 0 13.3 12.5 09/04/2006 11:00:00 2.5 0.7 4.6 0.7 1.8 0.8 4.2 0.4 2.6 0.7 4.6 0.7 5 17 36 165 12.7 0.2 13.3 11.9 09/04/2006 11:10:00 2.5 0.7 3.4 0.4 1.9 0.7 3.4 0.4 2.8 0.5 4.2 1.5 10 12 19 165 12.2 0.2 12.7 11.9 09/04/2006 11:20:00 2.6 0.6 3.8 1.1 2.2 0.8 3.8 0.7 3 0.6 4.2 1.5 4 22 354 165 13.1 0.2 13.5 12.7 09/04/2006 11:30:00 3 0.9 6.1 1.5 2.8 1 6.1 0.7 3.3 0.8 6.1 1.1 36 21 60 165 12.4 0.2 13 11.9 09/04/2006 11:40:00 2.8 0.7 4.9 0.7 2.7 0.8 4.6 0.4 3.1 0.7 4.9 1.5 39 9 44 165 12.4 0.1 12.7 11.9 09/04/2006 11:50:00 3 0.5 4.6 1.9 2.9 0.5 4.6 1.5 3.3 0.5 4.6 1.9 40 9 37 165 12.9 0.2 13.3 12.5 09/04/2006 12:00:00 3.1 0.8 4.9 1.5 3 0.8 4.9 1.1 3.3 0.8 5.3 1.5 38 9 40 165 13.3 0.1 13.8 12.7 09/04/2006 12:10:00 3.7 0.6 5.3 1.9 3.6 0.7 5.3 1.9 3.9 0.7 5.3 2.3 36 10 25 165 12.8 0.2 13.3 12.5 09/04/2006 12:20:00 4.1 0.6 5.7 2.6 4 0.6 5.7 2.3 4.2 0.6 5.7 2.6 43 9 42 165 12.5 0 13 12.2 09/04/2006 12:30:00 3.3 0.8 4.9 1.5 3.1 0.8 4.9 1.1 3.6 0.7 5.3 1.9 45 9 35 165 13 0.1 13.3 12.7 09/04/2006 12:40:00 3 0.6 4.2 1.5 2.8 0.7 4.2 1.1 3.2 0.6 4.6 1.5 42 10 57 165 13.3 0 13.5 13 09/04/2006 12:50:00 3.2 0.6 4.9 1.9 3.2 0.6 4.9 1.9 3.5 0.6 5.7 2.3 41 10 16 165 12.8 0.2 13.5 12.5 09/04/2006 13:00:00 4.2 0.9 6.1 1.5 4.2 0.9 6.1 1.5 4.4 0.9 6.5 1.5 43 11 34 165 12.4 0 12.7 12.2 09/04/2006 13:10:00 4.4 0.6 6.1 2.3 4.4 0.6 6.1 2.6 4.5 0.6 6.1 3 45 8 33 165 12.9 0.2 13 12.5 09/04/2006 13:20:00 3.9 0.6 5.3 1.9 4.1 0.6 5.3 1.9 4.1 0.5 5.3 2.6 53 12 57 165 13.1 0.2 13.5 13 09/04/2006 13:30:00 3.8 0.7 5.3 1.9 4 0.7 5.3 1.9 3.9 0.6 5.3 1.9 63 20 52 165 13.3 0.2 13.8 12.7 09/04/2006 13:40:00 3.7 0.7 5.7 2.3 3.9 0.7 5.3 2.3 3.8 0.8 5.7 1.9 47 17 39 165 13.7 0.1 14.1 13.3 09/04/2006 13:50:00 4.2 0.5 5.3 3 4.3 0.5 5.3 3 4.3 0.5 5.3 3 45 7 46 165 12.7 0.4 13.8 11.9 09/04/2006 14:00:00 3.2 0.7 4.9 1.5 3.4 0.7 4.9 1.5 3.5 0.6 4.9 1.9 49 12 26 165 12.5 0.5 13.3 11.9 09/04/2006 14:10:00 2.9 0.7 5.3 1.1 3.1 0.7 5.3 1.5 2.8 0.7 4.9 1.1 62 33 116 165 13.5 0.3 14.4 13 09/04/2006 14:20:00 3.1 0.5 4.2 0.7 3.2 0.5 4.6 1.5 3.2 0.5 4.6 1.9 53 16 79 165 12.5 0.1 13.3 12.2 09/04/2006 14:30:00 3.8 0.5 4.9 2.3 4 0.4 4.9 2.6 3.9 0.5 4.9 2.3 47 9 44 165 11.9 0.2 12.5 11.7 09/04/2006 14:40:00 3.1 0.5 4.2 1.9 3.3 0.5 4.2 1.9 3.3 0.5 4.6 1.9 46 9 50 165 12.1 0.2 12.7 11.7 09/04/2006 14:50:00 3.1 0.9 4.9 1.1 3.3 0.9 4.9 0.4 3.1 1 4.9 0.7 90 35 98 165 13 0.1 13.3 12.7 09/04/2006 15:00:00 3 0.6 4.6 1.1 3.1 0.6 4.9 1.9 2.9 0.5 4.2 0.7 74 24 110 165 12.3 0.3 12.7 11.7 09/04/2006 15:10:00 2.9 0.5 4.2 1.5 3.1 0.5 4.2 1.9 2.9 0.5 4.2 1.5 63 11 58 165 11.3 0.1 11.7 10.9 09/04/2006 15:20:00 3.1 0.5 4.2 1.9 3.4 0.5 4.6 1.9 3.3 0.4 4.2 2.3 53 9 61 165 11.4 0.1 11.7 11.1 09/04/2006 15:30:00 3.1 0.5 4.2 1.9 3.2 0.5 4.2 1.9 3.2 0.5 4.2 1.9 44 7 36 165 11.5 0 11.7 11.4 09/04/2006 15:40:00 2.9 0.5 4.6 1.5 3 0.5 4.6 1.5 2.9 0.5 4.2 1.9 53 20 44 165 11.7 0.6 13.3 11.1 09/04/2006 15:50:00 2.4 0.7 3.8 0.4 2.5 0.7 3.8 0.4 2.7 0.7 3.8 0.7 44 22 40 165 12.5 0.3 13.3 11.7 09/04/2006 16:00:00 2.9 0.8 4.6 0.7 3 0.8 4.6 1.1 2.8 0.8 4.6 0.7 68 27 91 165 12.7 0.3 13.3 11.9 09/04/2006 16:10:00 3.1 0.5 4.2 1.5 3.1 0.5 4.2 1.9 3.1 0.5 4.6 1.5 54 9 52 165 11.6 0.1 12.2 11.1 09/04/2006 16:20:00 3.2 0.5 4.6 1.5 3.4 0.5 4.9 1.5 3.3 0.5 4.6 1.9 53 9 56 165 11.1 0 11.4 10.9 09/04/2006 16:30:00 1.9 0.5 3 0.7 2.1 0.5 3 0.4 2.1 0.4 3 0.7 63 17 68 165 11 0.3 11.7 10.3 09/04/2006 16:40:00 2 1 4.6 0.4 2.1 1 4.9 0.4 2 0.8 4.2 0.4 69 36 116 165 11.6 0 11.9 11.1 09/04/2006 16:50:00 2.5 0.6 4.2 1.5 2.7 0.6 4.2 1.5 2.7 0.5 3.8 1.5 76 14 70 165 11.1 0.1 11.7 10.6 09/04/2006 17:00:00 2.6 0.6 4.2 0.4 2.7 0.6 4.6 0.7 2.6 0.6 4.2 0.7 81 20 102 165 11 0 11.1 10.6 09/04/2006 17:10:00 2.4 0.4 3.4 1.5 2.6 0.3 3.4 1.9 2.5 0.4 3.4 1.1 83 11 89 165 10.9 0.1 11.1 10.6 09/04/2006 17:20:00 2.4 0.5 3.8 0.7 2.6 0.5 4.2 1.1 2.4 0.5 3.4 1.1 86 15 84 165 11 0 11.4 10.3 09/04/2006 17:30:00 2.9 0.5 4.2 1.5 3 0.5 4.2 1.5 2.9 0.5 4.2 1.5 55 11 57 165 10.7 0 10.9 10.3 09/04/2006 17:40:00 2.4 0.6 4.2 0.7 2.5 0.6 3.8 1.1 2.5 0.6 4.6 0.7 46 10 43 165 10.7 0.1 10.9 10.6 09/04/2006 17:50:00 1.8 0.7 3 0.4 1.8 0.7 3.4 0.4 2 0.6 3.4 0.7 49 18 33 165 10.7 0 10.9 10.3 09/04/2006 18:00:00 1.2 0.7 3 0.4 1 0.7 3 0.4 1.2 0.6 3 0.4 60 28 21 165 10.7 0 10.9 10.6 09/04/2006 18:10:00 2.1 0.6 3.4 0.7 2.3 0.8 3.8 0.4 2.3 0.6 3.4 0.7 103 11 106 165 10.8 0 11.1 10.6 09/04/2006 18:20:00 2 0.5 3.4 0.7 2.1 0.5 3.4 0.4 2.2 0.5 3.8 1.1 90 14 101 165 10.5 0 10.9 10.1 09/04/2006 18:30:00 2.5 0.3 3.8 1.9 2.6 0.3 3.8 1.9 2.7 0.4 3.4 1.9 74 8 60 165 10.2 0.1 10.9 9.6 09/04/2006 18:40:00 1.1 0.6 2.6 0.4 1 0.7 2.6 0.4 1.4 0.6 2.6 0.4 86 9 81 165 10.1 0 10.6 9.6 09/04/2006 18:50:00 1.6 0.5 3 0.4 1.5 0.6 3 0.4 1.7 0.5 2.6 0.7 77 13 71 165 10 0 10.3 9.6 09/04/2006 19:00:00 2.1 0.4 3 1.1 2 0.4 3 0.7 2.2 0.4 3 1.1 67 9 77 165 10.1 0.1 10.6 9.8 09/04/2006 19:10:00 2.1 0.5 3.4 1.1 2.1 0.5 3.4 0.7 2.3 0.5 3.4 1.1 70 9 72 165 10.2 0 10.6 9.8 09/04/2006 19:20:00 2.2 0.4 3 1.1 2.3 0.4 3.4 0.7 2.3 0.4 3.4 0.7 73 10 73 165 10 0.1 10.3 9.6 09/04/2006 19:30:00 1.6 0.7 2.6 0.4 1.6 0.7 2.6 0.4 1.7 0.6 3 0.4 85 8 86 165 9.9 0.1 10.6 9.3 09/04/2006 19:40:00 1.4 0.6 2.6 0.4 1.2 0.8 2.6 0.4 1.7 0.5 2.6 0.7 97 7 90 165 9.5 0.2 10.3 9 09/04/2006 19:50:00 1.1 0.4 2.3 0.4 1.1 0.5 2.3 0.4 1.5 0.3 2.6 0.7 86 16 89 165 9.4 0 9.6 9 09/04/2006 20:00:00 0.9 0.3 1.9 0.4 0.9 0.4 1.9 0.4 1.4 0.2 1.9 1.1 79 4 87 165 9.3 0 9.6 9 09/04/2006 20:10:00 1.6 0.3 2.3 1.1 1.7 0.3 2.3 1.1 1.8 0.3 2.6 1.1 90 6 83 165 9.2 0.1 9.6 8.8 09/04/2006 20:20:00 1.2 0.3 1.9 0.4 1.3 0.3 1.9 0.4 1.5 0.2 2.3 1.1 96 8 88 165 9 0.1 9.3 8.8 09/04/2006 20:30:00 1.6 0.2 1.9 1.1 1.6 0.2 1.9 1.1 1.8 0.2 2.3 1.1 114 7 102 165 9 0.1 9.3 8.5 09/04/2006 20:40:00 0.9 0.4 1.5 0.4 0.9 0.4 1.9 0.4 1.2 0.4 1.9 0.4 123 0 122 165 9 0.1 9.3 8.8 09/04/2006 20:50:00 0.5 0.3 1.5 0.4 0.5 0.2 1.1 0.4 0.9 0.4 1.9 0.4 114 4 115 165 9 0.1 9.3 8.8 09/04/2006 21:00:00 1 0.5 1.9 0.4 1 0.5 1.9 0.4 1.4 0.3 2.3 0.7 130 4 136 165 9 0.2 9.3 8.5 09/04/2006 21:10:00 1.2 0.3 1.9 0.4 1.1 0.4 1.9 0.4 1.5 0.2 1.9 0.7 135 0 136 165 9 0.2 9.3 8.5 09/04/2006 21:20:00 0.9 0.4 1.9 0.4 0.8 0.4 1.9 0.4 1.2 0.3 2.3 0.4 136 7 124 165 9 0.2 9.3 8.5 09/04/2006 21:30:00 0.6 0.3 1.5 0.4 0.4 0.2 1.1 0.4 1 0.3 1.5 0.4 146 3 144 165 9.1 0.1 9.3 8.5 09/04/2006 21:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 150 0 165 165 8.9 0 9.6 8.8 09/04/2006 21:50:00 0.7 0.4 1.5 0.4 0.4 0 0.4 0.4 0.7 0.4 1.9 0.4 156 5 155 165 8.7 0 9 8.5 09/04/2006 22:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0.1 1.1 0.4 164 0 165 165 8.9 0 9 8.8 09/04/2006 22:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 164 0 165 165 8.8 0 9 8.8 09/04/2006 22:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 149 7 165 165 8.9 0 9 8.8 09/04/2006 22:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 123 15 165 165 8.9 0.1 9 8.8 09/04/2006 22:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0.1 0.7 0.4 112 0 165 165 9.2 0 9.3 9 09/04/2006 22:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 112 0 165 165 9.4 0.1 9.6 9 09/04/2006 23:00:00 0.4 0.1 1.1 0.4 0.4 0 0.4 0.4 0.5 0.3 1.5 0.4 107 8 92 165 9.6 0 9.8 9.6 09/04/2006 23:10:00 1.3 0.3 1.9 0.7 1.1 0.6 1.9 0.4 1.6 0.3 2.3 1.1 79 12 78 165 9.7 0 9.8 9.6 09/04/2006 23:20:00 1.1 0.3 1.9 0.4 0.6 0.4 1.5 0.4 1 0.5 1.9 0.4 49 7 57 165 9.5 0 9.6 9.3 09/04/2006 23:30:00 1.9 0.5 2.6 0.4 1.8 0.7 2.6 0.4 1.9 0.5 2.6 0.7 76 10 86 165 9.4 0 9.6 9.3 09/04/2006 23:40:00 2.6 0.3 3.4 1.9 2.6 0.3 3.4 1.9 2.6 0.2 3 2.3 70 6 85 165 9.6 0 9.8 9.3 09/04/2006 23:50:00 3 0.4 3.8 2.3 3 0.4 3.8 1.9 2.9 0.4 3.8 1.9 66 6 71 165 9.6 0 9.8 9.6 09/05/2006 00:00:00 2.6 0.3 3.4 1.9 2.5 0.4 3.4 1.5 2.4 0.3 3 1.9 63 8 68 165 9.6 0 9.6 9.3 09/05/2006 00:10:00 2.8 0.4 3.8 1.9 2.8 0.4 3.4 1.9 2.7 0.3 3.4 1.9 62 5 65 165 9.5 0 9.6 9 09/05/2006 00:20:00 2.5 0.3 3.4 1.9 2.5 0.3 3.4 1.9 2.6 0.3 3.4 1.9 59 6 73 165 9.5 0 9.6 9.3 09/05/2006 00:30:00 2.8 0.3 3.8 1.9 2.9 0.4 3.8 1.9 2.7 0.3 3.8 1.9 74 7 75 165 9.6 0.1 10.3 9 09/05/2006 00:40:00 3 0.4 3.8 1.9 3 0.4 3.8 1.9 2.8 0.4 3.8 1.9 79 5 77 165 9.6 0.1 9.8 9 09/05/2006 00:50:00 3.3 0.2 3.8 2.6 3.4 0.2 3.8 2.6 3.2 0.3 3.8 1.9 90 3 84 165 9.6 0.1 9.8 9 09/05/2006 01:00:00 3.1 0.3 3.8 2.3 3.2 0.3 3.8 2.6 3.1 0.3 3.8 2.3 94 3 91 165 9.7 0.1 9.8 9 09/05/2006 01:10:00 2.6 0.4 3 1.1 2.6 0.4 3.4 0.7 2.5 0.4 3 0.7 94 9 97 165 9.6 0.1 9.8 9.3 09/05/2006 01:20:00 2.8 0.5 3.8 1.1 2.8 0.5 3.8 1.1 2.6 0.4 3.8 1.5 104 6 107 165 9.5 0.1 9.6 9 09/05/2006 01:30:00 2.4 0.5 3.4 1.5 2.4 0.5 3.8 1.5 2.3 0.5 3.4 1.1 102 7 107 165 9.6 0.1 9.6 9 09/05/2006 01:40:00 2.3 0.3 2.6 1.5 2.4 0.3 3 1.5 2.3 0.2 2.6 1.5 104 2 106 165 9.5 0 9.6 9 09/05/2006 01:50:00 2.3 0.2 2.6 1.9 2.5 0.2 3 1.9 2.5 0.2 3 1.9 106 2 103 165 9.4 0 9.6 9 09/05/2006 02:00:00 2.1 0.2 2.6 1.5 2.1 0.2 2.6 1.5 2.1 0.2 2.6 1.5 107 3 110 165 9.4 0 9.6 9.3 09/05/2006 02:10:00 2 0.4 2.6 1.1 2 0.4 2.6 0.7 2.1 0.3 2.6 1.5 106 2 106 165 9.4 0 9.6 9.3 09/05/2006 02:20:00 1.5 0.2 2.3 0.7 1.6 0.2 2.3 0.7 1.7 0.2 2.3 1.1 114 5 121 165 9.4 0 9.6 9.3 09/05/2006 02:30:00 1.5 0.2 2.3 0.7 1.6 0.3 2.3 1.1 1.6 0.2 2.3 1.1 108 5 113 165 9.2 0 9.3 9 09/05/2006 02:40:00 1.9 0.3 2.6 1.1 1.8 0.3 2.6 1.1 1.8 0.3 2.6 1.1 95 10 90 165 9.3 0 9.3 9 09/05/2006 02:50:00 1.7 0.3 2.3 0.7 1.6 0.3 2.3 0.4 1.7 0.2 2.3 1.1 89 2 90 165 9.2 0 9.3 9 09/05/2006 03:00:00 1.4 0.4 2.3 0.7 1.3 0.4 2.3 0.4 1.6 0.3 2.3 0.7 83 8 90 165 9.2 0 9.3 9 09/05/2006 03:10:00 1.6 0.3 2.3 0.7 1.5 0.3 2.3 0.4 1.8 0.3 2.6 1.1 84 6 85 165 9.2 0 9.3 9 09/05/2006 03:20:00 2.1 0.3 2.6 1.5 2.1 0.3 3 1.1 2.1 0.3 3 1.5 98 7 94 165 9.2 0 9.6 9 09/05/2006 03:30:00 1.2 0.4 2.3 0.4 1 0.6 2.3 0.4 1.3 0.4 2.3 0.7 103 9 94 165 9.4 0 9.6 9 09/05/2006 03:40:00 1.4 0.5 2.6 0.4 1.2 0.6 2.6 0.4 1.5 0.4 2.6 0.4 116 4 122 165 9.4 0 9.6 9.3 09/05/2006 03:50:00 1.7 0.4 2.6 0.4 1.7 0.4 2.6 0.4 1.7 0.4 2.3 0.7 124 7 132 165 9.4 0 9.6 9.3 09/05/2006 04:00:00 1.8 0.3 2.6 0.7 1.8 0.3 2.6 0.7 1.8 0.3 2.6 0.7 124 8 137 165 9.4 0 9.6 9.3 09/05/2006 04:10:00 1.7 0.4 2.6 0.4 1.8 0.5 2.6 0.4 1.8 0.3 2.6 0.4 124 6 121 165 9.4 0 9.6 9 09/05/2006 04:20:00 1.7 0.6 3.4 0.4 1.8 0.6 3.4 0.4 1.9 0.4 3 1.1 120 7 121 165 9.3 0 9.6 9 09/05/2006 04:30:00 2.3 0.4 3 1.5 2.4 0.4 3.4 1.5 2.2 0.4 3 1.5 117 6 122 165 9.4 0 9.6 9 09/05/2006 04:40:00 2.4 0.4 3 1.5 2.4 0.3 3 1.5 2.4 0.4 3.4 1.5 104 7 122 165 9.4 0 9.6 9 09/05/2006 04:50:00 2.2 0.5 3 1.1 2.3 0.5 3.4 1.5 2.4 0.5 3.4 1.5 110 5 101 165 9.3 0 9.6 9 09/05/2006 05:00:00 2.1 0.3 3 1.1 2.1 0.3 3 1.1 2.2 0.3 3 1.5 102 7 111 165 9.4 0 9.6 9 09/05/2006 05:10:00 3.1 0.5 4.2 1.9 3.1 0.5 4.2 1.9 3 0.5 4.2 1.5 87 9 77 165 9.4 0 9.6 9 09/05/2006 05:20:00 3.4 0.3 4.2 2.6 3.4 0.3 4.2 2.6 3.4 0.3 4.6 2.6 93 5 86 165 9.4 0 9.6 9 09/05/2006 05:30:00 3.3 0.4 4.2 2.3 3.3 0.4 4.2 2.3 3.1 0.4 4.2 2.3 85 8 84 165 9.3 0 9.8 8.8 09/05/2006 05:40:00 3.5 0.2 4.2 2.6 3.6 0.3 4.2 2.6 3.6 0.3 4.2 2.6 91 4 94 165 9 0 9 8.5 09/05/2006 05:50:00 3.5 0.3 4.2 2.6 3.6 0.3 4.6 2.6 3.4 0.4 4.2 1.9 83 7 84 165 9 0 9.3 8.5 09/05/2006 06:00:00 3.4 0.3 4.2 3 3.6 0.3 4.6 3 3.4 0.3 4.2 2.6 106 3 108 165 9.1 0 9.3 8.8 09/05/2006 06:10:00 3.7 0.3 4.6 3 3.9 0.3 4.9 3 3.5 0.4 4.2 2.6 105 6 112 165 9.4 0 9.6 9 09/05/2006 06:20:00 3.5 0.2 4.2 2.6 3.8 0.3 4.2 2.6 3.3 0.4 3.8 1.9 90 7 97 165 9.6 0 9.6 9.3 09/05/2006 06:30:00 3.4 0.4 4.2 2.6 3.5 0.4 4.6 2.6 3 0.4 4.2 2.3 81 6 88 165 9.6 0 9.6 9.6 09/05/2006 06:40:00 2.8 1 4.6 0.7 2.7 1.1 4.6 0.7 2.6 0.9 4.6 0.7 54 17 79 165 9.6 0 10.1 9.6 09/05/2006 06:50:00 3.4 0.8 5.3 1.1 3.5 0.8 5.3 1.1 3.3 0.8 5.3 1.1 64 13 73 165 9.6 0 9.8 9.6 09/05/2006 07:00:00 2.9 0.6 4.6 1.5 2.8 0.7 4.9 1.1 2.5 0.5 3.8 1.5 55 13 54 165 9.8 0 9.8 9.6 09/05/2006 07:10:00 2.2 0.6 4.2 0.7 2 0.7 4.6 0.4 2.2 0.6 4.2 0.7 56 13 99 165 9.8 0 9.8 9.6 09/05/2006 07:20:00 5.6 1.8 8.8 2.3 5.7 1.9 9.1 1.9 5.2 1.7 8.8 1.9 101 18 111 165 9.9 0.1 10.3 9.6 09/05/2006 07:30:00 7.3 0.6 8.8 4.9 7.5 0.6 8.8 5.7 6.8 0.7 8.4 4.9 101 6 107 165 10.1 0.1 10.3 9.6 09/05/2006 07:40:00 6.8 0.6 9.1 5.3 7.1 0.6 9.1 5.3 6.3 0.7 9.1 4.6 99 5 100 165 10.1 0.1 10.3 9.6 09/05/2006 07:50:00 6.7 0.8 8.8 4.9 6.9 0.8 9.1 5.3 6.4 0.9 8.8 4.2 103 5 107 165 10.2 0.1 10.6 9.6 09/05/2006 08:00:00 4.9 0.5 6.1 3.4 5.1 0.5 6.1 3.8 4.8 0.5 6.1 3.4 88 5 91 165 10.3 0 10.6 9.8 09/05/2006 08:10:00 3.8 0.7 4.9 1.9 3.9 0.8 5.3 1.9 3.8 0.7 4.9 1.9 81 7 84 165 10.4 0 10.6 10.1 09/05/2006 08:20:00 4.8 1.1 7.2 2.6 4.9 1.1 8 2.3 4.6 1.1 6.8 2.3 85 9 91 165 10.5 0 10.9 10.1 09/05/2006 08:30:00 4.9 0.8 6.8 3 4.9 0.8 6.8 3 4.7 0.7 6.5 3 99 9 99 165 10.4 0 10.9 9.8 09/05/2006 08:40:00 4.7 0.6 5.7 3 4.8 0.7 6.5 2.6 4.4 0.7 5.7 2.6 90 9 96 165 10.2 0.1 10.6 9.6 09/05/2006 08:50:00 4.9 0.6 6.8 3.4 5.1 0.6 6.8 3.8 4.7 0.6 6.1 3.4 95 10 97 165 10.1 0.1 10.6 9.6 09/05/2006 09:00:00 6.2 0.9 8.8 3.8 6.3 1 9.1 3.8 5.8 1 8.4 3.8 109 8 102 165 10.3 0.1 10.6 9.8 09/05/2006 09:10:00 5.6 0.7 7.6 3.8 5.7 0.7 7.6 3.8 5.3 0.6 6.8 4.2 103 8 119 165 10.4 0 11.1 10.1 09/05/2006 09:20:00 4.8 0.8 6.5 3 4.9 0.8 6.8 3 4.4 0.7 6.1 2.6 89 11 87 165 10.1 0.1 10.6 9.8 09/05/2006 09:30:00 4.4 1.2 7.2 1.9 4.4 1.4 7.2 1.5 4.1 1.2 6.8 1.9 65 21 94 165 10.2 0.1 10.6 9.8 09/05/2006 09:40:00 3.3 0.5 4.6 2.3 3.2 0.6 4.9 1.9 3.3 0.5 4.6 2.3 61 13 87 165 10.3 0 10.9 9.8 09/05/2006 09:50:00 3.7 0.7 6.1 2.3 3.7 0.8 6.5 1.9 3.5 0.6 4.9 1.9 74 13 87 165 10.7 0.1 11.1 10.3 09/05/2006 10:00:00 3.6 0.6 4.9 1.9 3.5 0.7 5.3 1.9 3.4 0.7 4.9 1.1 60 12 58 165 10.7 0.1 11.1 10.3 09/05/2006 10:10:00 2.7 1 5.7 1.1 2.6 1.1 5.7 1.1 2.3 1.1 6.1 0.4 73 19 84 165 10.9 0 11.1 10.6 09/05/2006 10:20:00 5.3 0.8 6.8 3 5.4 0.9 6.8 3.4 5.2 0.8 6.8 3 95 7 92 165 11.1 0.2 11.4 10.6 09/05/2006 10:30:00 5.8 0.8 8 3 5.9 0.9 8.4 3 5.6 0.8 8.4 3 104 9 105 165 11.3 0.1 11.7 10.9 09/05/2006 10:40:00 6.1 0.8 8 3.4 6.2 0.8 8.4 3.4 5.7 0.8 8 3.4 105 8 117 165 11.3 0.1 11.7 10.9 09/05/2006 10:50:00 5.1 0.6 6.8 3.4 5.3 0.6 7.2 3.4 5 0.6 6.5 3.8 96 9 74 165 11.5 0 11.7 11.1 09/05/2006 11:00:00 5.7 0.8 7.2 3.8 5.9 0.8 7.2 3.8 5.5 0.8 6.8 3.4 99 9 99 165 11.5 0 11.7 11.1 09/05/2006 11:10:00 6.1 0.8 7.6 3.8 6.2 0.8 7.6 3.8 5.7 0.9 7.6 3.4 99 10 97 165 11.3 0 11.7 11.1 09/05/2006 11:20:00 6.7 0.9 8.4 4.6 6.7 0.9 8.4 4.2 6.3 0.8 8 4.6 103 9 99 165 11.4 0 11.7 11.4 09/05/2006 11:30:00 6.8 0.8 8.8 4.6 6.9 0.8 9.1 4.2 6.5 0.8 8.4 4.2 101 9 103 165 11.9 0.2 12.5 11.4 09/05/2006 11:40:00 6.6 1 8.8 3.8 6.7 1 8.8 3.4 6.5 0.9 8.8 3.8 103 10 89 165 13.2 0.2 13.5 12.5 09/05/2006 11:50:00 6.8 0.8 9.1 4.6 6.9 0.8 9.1 4.6 6.5 0.9 9.1 3.8 101 9 114 165 12.7 0.1 13.3 12.2 09/05/2006 12:00:00 6.1 0.9 8.4 3.4 6.2 1 8.4 3.8 5.9 0.9 9.1 3.8 98 10 103 165 12.7 0.1 13 12.5 09/05/2006 12:10:00 7 0.8 8.4 4.6 7.1 0.8 8.4 4.6 6.9 0.8 8.8 4.9 107 7 95 165 13.1 0.2 13.5 12.7 09/05/2006 12:20:00 5.9 0.8 7.2 3.4 5.9 0.8 8 3.4 5.8 0.8 7.6 3.4 103 9 102 165 13.3 0.3 14.1 12.7 09/05/2006 12:30:00 5.7 0.8 8 3.8 5.8 0.8 7.6 3.4 5.9 0.9 8.4 3.8 107 9 111 165 13.9 0.2 14.4 13.5 09/05/2006 12:40:00 5.9 0.7 7.2 3 5.9 0.7 7.6 3 6 0.8 8 3.4 108 9 117 165 13.4 0 13.5 13.3 09/05/2006 12:50:00 6 0.8 8 4.2 6 0.8 8 3.8 5.9 0.8 8 3.4 107 9 110 165 13.3 0.1 13.5 13 09/05/2006 13:00:00 5.6 0.8 7.6 3.8 5.7 0.8 8 3.8 5.5 0.8 7.6 3.8 107 9 103 165 12.6 0.2 13 12.2 09/05/2006 13:10:00 5.1 0.7 6.5 3 5.1 0.7 6.8 3 5 0.6 6.5 3.4 109 9 108 165 12.6 0 12.7 12.5 09/05/2006 13:20:00 4.7 0.8 6.5 2.3 4.7 0.9 6.8 2.3 4.7 0.8 6.5 2.3 100 12 87 165 12.7 0.1 13 12.5 09/05/2006 13:30:00 5.1 0.9 7.2 2.6 5.1 0.9 7.6 2.6 5 1 7.2 2.3 101 11 105 165 13.2 0.3 13.8 12.7 09/05/2006 13:40:00 5.3 0.9 7.2 3 5.5 0.9 7.2 3 5.3 0.9 7.6 3 99 9 104 165 13.1 0.3 13.5 12.5 09/05/2006 13:50:00 4.2 0.8 6.5 1.9 4.2 0.9 6.8 2.3 4.2 0.8 6.8 2.3 91 13 105 165 12.7 0.2 13.3 12.5 09/05/2006 14:00:00 4.4 0.8 6.8 2.3 4.4 0.8 6.5 2.3 4.3 0.8 7.2 1.9 87 20 102 165 13.5 0 13.8 13.3 09/05/2006 14:10:00 3.9 0.8 5.7 1.9 3.9 0.8 5.7 1.9 3.8 0.8 6.1 1.5 89 22 111 165 13.5 0 13.8 13.3 09/05/2006 14:20:00 3.4 0.8 6.1 1.9 3.5 0.9 6.1 1.9 3.4 0.8 6.5 1.5 81 27 105 165 13.4 0 14.1 13.3 09/05/2006 14:30:00 3.6 0.8 5.7 1.5 3.7 0.9 5.7 1.5 3.7 0.9 5.7 1.5 87 17 119 165 13.3 0.2 13.8 12.7 09/05/2006 14:40:00 3.1 0.6 4.9 1.5 3 0.6 4.9 1.5 3.1 0.6 4.9 1.1 57 24 42 165 12.9 0.1 13.3 12.7 09/05/2006 14:50:00 3.5 0.7 5.3 1.5 3.4 0.7 5.3 1.1 3.5 0.7 5.7 1.9 40 10 54 165 12.6 0 13 12.5 09/05/2006 15:00:00 2.6 0.9 5.7 0.7 2.6 0.9 5.7 0.7 2.8 0.9 5.3 0.7 65 23 85 165 13.1 0.1 13.5 12.7 09/05/2006 15:10:00 4.1 1 6.5 0.4 4.2 1 6.5 0.7 4 1 6.1 1.1 55 23 33 165 13 0.5 13.8 12.2 09/05/2006 15:20:00 3.1 0.6 4.6 1.5 3 0.7 4.6 0.7 3 0.7 5.3 1.1 38 17 53 165 12.3 0 12.7 12.2 09/05/2006 15:30:00 4.8 1.1 6.5 2.3 4.7 1.1 6.8 2.6 4.8 1.1 7.2 2.6 35 11 42 165 12.1 0.3 12.7 11.7 09/05/2006 15:40:00 4.7 0.7 6.8 2.6 4.5 0.7 6.8 2.3 4.9 0.7 6.8 3 20 9 33 165 12.2 0.2 12.5 11.9 09/05/2006 15:50:00 4 0.5 5.7 2.3 4 0.5 5.3 2.3 4.2 0.6 5.3 2.6 26 7 34 165 12 0.3 12.7 11.4 09/05/2006 16:00:00 3.8 1.5 7.2 1.5 4 1.5 7.2 1.5 3.9 1.4 6.8 1.5 56 13 68 165 11.2 0.1 11.7 10.6 09/05/2006 16:10:00 5.1 1 7.6 3 5.3 1.1 8 3 5.1 1.1 8 3 66 11 56 165 11.3 0.1 11.7 10.9 09/05/2006 16:20:00 5.8 1 8.8 3.8 6 1 9.1 3.8 5.8 0.9 8.4 3.8 70 9 73 165 11.3 0.1 11.4 10.9 09/05/2006 16:30:00 6.4 0.8 8.8 4.6 6.6 0.8 8.8 4.9 6.3 0.9 9.1 3.8 67 8 61 165 11.3 0.1 11.4 10.6 09/05/2006 16:40:00 6.5 0.9 8.4 4.2 6.7 1 8.8 4.2 6.5 1 8.4 4.2 67 7 66 165 11.3 0.1 11.7 10.6 09/05/2006 16:50:00 6.4 0.8 8.4 4.2 6.6 0.8 8.4 4.6 6.4 0.8 8 4.2 66 6 71 165 11.3 0 11.4 11.1 09/05/2006 17:00:00 4.9 1 7.6 2.6 5.1 1 7.6 3 4.8 1 7.2 3 60 13 66 165 11.3 0 11.7 11.1 09/05/2006 17:10:00 5 1.1 7.6 2.3 5 1 7.6 2.3 4.8 1 7.6 2.3 35 16 33 165 11.2 0 11.4 10.9 09/05/2006 17:20:00 7.2 1.1 9.9 4.2 6.9 1.2 9.5 3.4 6.8 1.1 9.9 3.8 19 8 14 165 11 0 11.4 10.6 09/05/2006 17:30:00 6.8 1.6 10.3 3.8 6.3 1.3 9.5 3.4 6.5 1.6 10.3 3.4 19 9 18 165 11 0 11.1 10.6 09/05/2006 17:40:00 7.8 0.9 10.3 5.7 7.1 1.2 10.3 3.4 7.6 0.9 9.9 4.9 16 8 22 165 11 0 11.1 10.6 09/05/2006 17:50:00 7.2 0.8 9.1 4.9 7 1 9.1 4.2 7 1 9.5 4.6 23 8 29 165 11 0 11.1 10.6 09/05/2006 18:00:00 8 1 9.9 4.6 7.5 1.1 9.9 4.6 7.9 1 10.3 4.6 18 6 22 165 10.9 0 11.1 10.9 09/05/2006 18:10:00 7.8 0.9 9.9 5.3 7.1 1.1 9.5 4.2 7.5 0.9 9.9 5.3 16 8 16 165 10.8 0 11.1 10.9 09/05/2006 18:20:00 7.6 1.2 10.3 4.6 7.3 1.3 10.3 3.4 7.3 1.2 10.3 4.6 21 8 24 165 10.8 0 11.1 10.9 09/05/2006 18:30:00 8.2 0.8 9.9 6.1 7.5 1.1 9.5 4.2 7.9 0.9 9.9 5.3 16 7 18 165 10.7 0.1 11.1 10.3 09/05/2006 18:40:00 8.4 0.8 10.7 6.5 6.9 1.3 10.3 3.8 8.3 0.8 10.3 6.5 12 7 14 165 10.4 0 10.9 10.3 09/05/2006 18:50:00 7.3 0.9 9.9 5.3 5.5 1 8.4 3 7.1 0.8 9.9 5.3 8 7 5 165 10.3 0 10.6 10.1 09/05/2006 19:00:00 7.1 0.8 8.8 4.9 5.4 1 8.8 3 7 0.8 9.1 4.9 7 7 4 165 10.3 0 10.6 10.1 09/05/2006 19:10:00 6.4 0.8 8.4 4.2 5.4 1.1 7.6 2.6 6.3 0.8 8.8 4.9 12 8 11 165 10.2 0.1 10.6 9.8 09/05/2006 19:20:00 7 1.1 9.5 4.2 6.2 1.3 9.1 3.4 6.7 1.2 9.5 3.8 14 8 14 165 10.1 0.1 10.6 9.6 09/05/2006 19:30:00 7.9 1 9.9 4.9 6.9 1.3 9.5 3.4 7.6 1 10.3 5.3 14 8 15 165 10.1 0.2 10.6 9.6 09/05/2006 19:40:00 8.1 0.8 9.9 5.7 6.7 1.1 9.5 3.4 7.7 0.8 9.9 5.3 12 6 11 165 10.2 0.2 10.6 9.6 09/05/2006 19:50:00 7.2 1.1 9.9 4.6 6.6 1.2 9.1 3.8 7 1.1 9.9 4.2 18 8 11 165 10.2 0.2 10.6 9.6 09/05/2006 20:00:00 8.3 1 10.7 5.3 7.5 1.3 10.7 3.8 7.9 1.1 10.7 4.6 15 8 11 165 10.1 0.2 10.6 9.6 09/05/2006 20:10:00 8 0.9 9.9 5.7 6.9 1.1 9.1 3.8 7.8 0.9 10.3 5.7 13 7 21 165 10.1 0.2 10.9 9.6 09/05/2006 20:20:00 7.8 0.9 10.3 5.7 6.6 1.3 9.9 3.8 7.6 0.9 11.1 5.3 12 6 11 165 10.1 0.2 10.6 9.6 09/05/2006 20:30:00 8.1 0.9 10.3 5.7 6.5 1.2 10.3 3.8 7.8 0.9 10.3 5.7 10 6 11 165 10.2 0.1 10.6 9.6 09/05/2006 20:40:00 8.4 1.2 10.7 5.3 7.3 1.7 10.7 3.8 7.9 1.1 10.7 5.3 13 9 11 165 10.2 0 10.6 9.6 09/05/2006 20:50:00 8.5 1 11.1 6.1 7.9 1.2 11.1 4.2 8.1 1.1 11.1 5.7 17 8 28 165 10.2 0.1 10.6 9.6 09/05/2006 21:00:00 8.5 0.9 10.3 5.7 8 1.1 10.3 4.9 8.2 1 10.3 5.7 18 7 16 165 10.2 0 10.3 9.6 09/05/2006 21:10:00 7.7 0.8 9.1 5.7 6.5 1 8.8 3.8 7.4 0.8 9.1 4.6 13 6 26 165 10.1 0 10.3 9.8 09/05/2006 21:20:00 5.4 1.1 8 3 5.2 1.1 8 3 5.2 1.1 8 3 25 9 31 165 10.1 0 10.3 9.8 09/05/2006 21:30:00 6.7 0.9 9.1 4.2 6 1.1 8.8 3 6.4 1 9.5 4.2 19 10 26 165 10.1 0 10.3 9.8 09/05/2006 21:40:00 6.4 1.2 9.1 3.8 5.7 1.2 8.4 3 6.2 1.1 9.1 3.4 16 8 27 165 10.2 0 10.6 9.8 09/05/2006 21:50:00 7.7 0.9 9.9 4.6 6.8 1.3 9.1 3 7.3 0.9 9.5 4.6 14 8 22 165 10.5 0 10.6 10.1 09/05/2006 22:00:00 7.6 1 10.7 4.6 6.9 1.3 10.3 3.8 7.5 1 10.3 5.3 18 8 23 165 10.5 0 10.6 10.3 09/05/2006 22:10:00 8.7 1 11.8 6.1 8 1.2 11.5 4.6 8.3 1 11.1 5.7 17 7 21 165 10.5 0 10.9 10.3 09/05/2006 22:20:00 9.3 1 11.5 6.5 8.4 1.3 11.5 4.9 8.8 1.1 11.5 5.7 16 7 6 165 10.5 0 10.9 10.3 09/05/2006 22:30:00 9 1 11.8 6.5 7.2 1.2 11.1 4.2 8.5 1.2 11.5 5.7 7 8 6 165 10.6 0 10.9 10.3 09/05/2006 22:40:00 9.1 1.2 11.8 6.1 8.3 1.5 11.5 4.2 8.8 1.2 12.2 5.7 16 7 15 165 10.6 0 10.9 10.3 09/05/2006 22:50:00 8.5 1.2 11.8 5.3 7.7 1.5 11.8 3.8 8.2 1.2 11.1 5.3 17 8 23 165 10.7 0 10.9 10.3 09/05/2006 23:00:00 8.5 1 11.5 4.6 7.3 1.5 11.5 3.4 8.2 1 11.1 4.9 13 8 21 165 10.6 0 10.9 10.3 09/05/2006 23:10:00 8.6 1 11.5 5.7 7.1 1.3 10.7 4.2 8.3 1 10.3 5.7 11 7 13 165 10.5 0 10.9 10.3 09/05/2006 23:20:00 8.6 1 11.1 5.7 7.1 1.2 10.3 4.2 8.4 1 11.1 5.7 11 7 15 165 10.4 0 10.6 10.3 09/05/2006 23:30:00 8.7 0.9 11.1 6.1 6.9 1.3 10.3 3.4 8.4 0.9 11.1 6.1 11 6 9 165 10.3 0 10.6 10.1 09/05/2006 23:40:00 8.8 0.8 10.7 6.5 6.3 1.1 9.5 3.4 8.4 0.9 10.7 5.7 7 6 16 165 10.1 0.1 10.6 9.8 09/05/2006 23:50:00 9 0.9 11.1 6.5 6.5 1.3 9.5 3.8 8.6 1 11.1 5.7 7 5 9 165 10.1 0.1 10.3 9.6 09/06/2006 00:00:00 8.3 1 10.7 6.1 6.1 1.2 9.1 3 8.1 1.1 11.1 5.3 8 7 8 165 10 0.1 10.3 9.6 09/06/2006 00:10:00 8.1 1.1 10.7 5.3 6.1 1.3 9.1 3.4 7.9 1.2 10.3 4.9 8 6 13 165 10.1 0 10.3 9.8 09/06/2006 00:20:00 8.9 1.2 11.1 5.7 7 1.2 11.1 4.2 8.8 1.2 11.1 5.3 10 6 7 165 10.1 0.1 10.6 9.8 09/06/2006 00:30:00 9.1 1 11.8 6.8 6.9 1.5 11.1 4.2 8.8 1.1 11.8 6.5 8 9 9 165 10.1 0.2 10.9 9.6 09/06/2006 00:40:00 7.4 1.1 11.1 4.9 6.2 1.4 10.7 3 7 1.1 10.3 4.2 1 13 357 165 10 0 10.3 9.6 09/06/2006 00:50:00 8.2 1.5 12.6 4.6 7 1.2 10.7 4.2 8 1.5 11.8 5.3 16 9 8 165 10 0 10.3 9.6 09/06/2006 01:00:00 9.5 1.7 13 5.3 7.8 1.9 12.6 3.8 9.2 1.7 13 4.9 10 9 15 165 10.1 0 10.3 9.6 09/06/2006 01:10:00 9.9 1.3 14.1 6.1 8.4 1.7 12.6 4.6 9.6 1.5 13.7 5.3 12 10 4 165 10.1 0 10.6 9.6 09/06/2006 01:20:00 10.3 1.5 13.7 6.5 9.1 1.5 13 4.6 10 1.5 13.3 6.8 14 8 4 165 10.1 0.1 10.3 9.6 09/06/2006 01:30:00 11.4 1.3 13.7 7.6 10 1.7 13.3 6.1 10.9 1.2 13.7 6.8 14 7 23 165 10.1 0.1 10.6 9.6 09/06/2006 01:40:00 12.5 1.5 15.3 8.4 11.5 2 14.9 6.8 11.8 1.6 15.6 8 17 7 15 165 10 0 10.6 9.6 09/06/2006 01:50:00 10.6 1 12.6 7.2 8.1 1.4 12.2 4.9 10.1 1 12.6 7.6 7 7 19 165 10 0 10.3 9.6 09/06/2006 02:00:00 11.2 1.3 14.5 6.8 8.4 1.7 13.3 4.9 10.9 1.5 15.6 7.6 6 8 353 165 10 0 10.3 9.6 09/06/2006 02:10:00 10.6 1.5 14.9 6.8 8.1 1.7 13.3 4.6 10.3 1.7 14.9 6.8 359 8 11 165 10 0 10.3 9.6 09/06/2006 02:20:00 10.5 1.4 13.7 7.2 8.5 1.7 13.3 4.9 10.1 1.6 13.3 6.1 355 8 10 165 10 0 10.3 9.6 09/06/2006 02:30:00 11.1 1.7 14.9 5.7 8.9 1.9 13.7 4.9 10.6 1.7 14.1 5.7 357 9 357 165 10 0 10.6 9.6 09/06/2006 02:40:00 10.7 1.3 14.9 8 8.1 2 13 4.2 10.2 1.3 14.5 7.2 358 9 357 165 10 0 10.6 9.6 09/06/2006 02:50:00 10.4 1.7 14.9 6.8 8.8 2.5 14.9 3.8 10 1.5 14.9 6.8 357 10 23 165 10 0 10.1 9.3 09/06/2006 03:00:00 11.2 1.5 16.1 7.2 9.3 2.1 15.3 4.9 10.6 1.5 16.4 6.8 355 9 12 165 9.9 0 10.1 9.6 09/06/2006 03:10:00 11.8 1.7 15.6 6.5 8.9 1.8 14.9 4.9 11.3 1.7 15.3 7.6 357 8 4 165 9.9 0 10.1 9.3 09/06/2006 03:20:00 10.9 1.7 16.4 6.8 8.8 1.9 16.8 4.6 10.1 1.7 14.1 5.3 354 9 347 165 9.8 0 10.1 9.3 09/06/2006 03:30:00 13 1.6 17.2 8.8 10.2 1.7 15.3 7.2 12.2 2 17.2 7.2 357 8 5 165 9.7 0.2 9.8 9 09/06/2006 03:40:00 15.2 1.7 20.2 10.3 12.2 2.1 17.9 7.6 14.5 2 20.6 10.3 357 9 355 165 9.9 0.2 10.3 9.3 09/06/2006 03:50:00 14.6 2.2 21.8 9.1 12.5 2.5 19.5 6.1 13.9 2.3 19.5 8.4 353 10 12 165 9.9 0.2 10.6 9.3 09/06/2006 04:00:00 14.2 2.2 19.9 9.5 12.3 2.4 18.7 6.8 13.8 2.4 19.9 8.8 356 12 1 165 9.8 0.2 10.3 9.3 09/06/2006 04:10:00 11.2 2 16.8 6.8 10.3 2.3 16.4 4.9 10.8 2 16.1 5.7 345 23 342 165 9.8 0 10.1 9 09/06/2006 04:20:00 9.9 1.3 13.3 6.5 9.9 1.3 12.6 6.5 9.5 1.5 13.3 6.1 325 12 325 165 10 0 10.3 9.3 09/06/2006 04:30:00 11.5 2.1 16.4 6.5 11.2 2.1 16.8 6.1 11.3 2.2 16.4 5.7 330 13 313 165 10 0 10.3 9.3 09/06/2006 04:40:00 11.8 1.8 16.1 6.8 11.7 1.7 15.6 6.1 11.3 1.7 15.6 6.5 322 12 322 165 10 0.1 10.3 9.3 09/06/2006 04:50:00 12.4 1.5 16.4 8.4 12.3 1.5 16.4 8 11.4 1.7 17.2 7.2 317 13 319 165 10.1 0.2 10.6 9.3 09/06/2006 05:00:00 12.1 2 16.8 7.2 11.9 2.1 16.8 6.8 11.7 2.1 17.2 6.8 327 14 324 165 10.2 0.1 10.6 9.6 09/06/2006 05:10:00 13 1.9 20.6 8.8 12.8 1.9 20.2 8.4 12.1 1.7 18.3 7.6 323 12 324 165 10.1 0.1 10.3 9.6 09/06/2006 05:20:00 14.1 1.8 19.5 9.1 14 1.8 19.5 9.1 13.3 2 18.7 8.4 321 11 329 165 10.2 0.1 10.6 9.8 09/06/2006 05:30:00 14.5 2 21.4 9.1 14.4 2 21 9.9 13.3 2.1 20.6 9.1 318 15 318 165 10.4 0.2 10.9 9.8 09/06/2006 05:40:00 14.9 1.8 19.5 8 14.7 1.8 19.9 8.8 13.7 2.2 19.1 8.4 320 13 292 165 10.6 0.1 10.9 9.8 09/06/2006 05:50:00 16.8 2.2 23.7 11.8 16.6 2.2 23.3 11.8 14.8 2.3 24.8 9.5 309 10 297 165 10.7 0.1 11.1 10.1 09/06/2006 06:00:00 16.7 2 22.1 11.1 16.5 2 21.8 11.5 15.2 2 21.4 11.1 318 13 308 165 10.6 0.1 11.1 9.8 09/06/2006 06:10:00 16.6 2.1 23.7 11.5 16.5 2 23.7 11.1 14.5 2.3 20.2 7.6 311 11 303 165 10.6 0.1 10.9 9.8 09/06/2006 06:20:00 17.7 2.1 23.7 11.8 17.6 2.1 24 11.5 16 2.5 23.7 10.7 312 11 311 165 10.7 0.1 10.9 9.8 09/06/2006 06:30:00 19 2.7 28.3 13 18.8 2.6 28.3 12.6 17.5 2.6 25.2 12.2 315 11 310 165 10.7 0 11.1 10.3 09/06/2006 06:40:00 20.7 2.4 30.6 16.1 20.5 2.4 29.8 16.1 18.7 2.6 26.8 11.1 312 10 297 165 10.8 0 11.4 10.3 09/06/2006 06:50:00 19.6 2.4 25.2 13.3 19.5 2.3 24.8 13.3 17.6 2.4 23.7 11.5 311 12 310 165 10.8 0 11.1 10.3 09/06/2006 07:00:00 17.7 2.3 24.8 11.8 17.5 2.2 24.8 11.8 15.4 2.3 25.2 10.7 309 11 313 165 10.9 0 11.1 10.6 09/06/2006 07:10:00 17.4 2.3 23.3 11.1 17.3 2.3 23.7 11.1 15.4 2.6 21 9.1 313 13 305 165 10.8 0 11.1 10.3 09/06/2006 07:20:00 18 2.3 24 12.2 17.8 2.3 24.4 11.8 16.6 2.6 24 6.8 318 14 297 165 10.7 0.1 11.1 10.3 09/06/2006 07:30:00 16.9 2.5 22.6 10.7 16.6 2.5 22.9 11.1 15.6 2.6 21.8 10.3 322 18 302 165 10.8 0.1 11.1 10.3 09/06/2006 07:40:00 17.1 2.1 24 11.5 16.8 2.2 24 11.5 16.1 2.4 23.3 10.7 326 15 339 165 10.8 0.1 11.1 10.3 09/06/2006 07:50:00 18.7 2.4 26.3 13.7 18.4 2.4 27.5 13 18.1 2.6 26.3 11.8 331 14 333 165 10.8 0.1 11.1 10.3 09/06/2006 08:00:00 18 1.9 23.3 11.8 17.7 1.9 23.7 11.1 16.5 2.2 21.8 10.7 318 15 302 165 10.7 0.1 11.1 10.3 09/06/2006 08:10:00 16.6 2.3 22.1 10.7 16.4 2.3 22.6 9.5 15.3 2.3 20.6 9.5 320 15 310 165 10.7 0.1 11.1 10.3 09/06/2006 08:20:00 15.5 2.7 22.9 8 15.1 2.8 22.6 8.4 14.2 2.3 21.8 9.1 329 16 297 165 10.8 0 11.1 10.6 09/06/2006 08:30:00 15.4 2.1 23.3 10.7 15.3 2.2 23.7 11.1 14.9 2.1 24 10.3 331 11 330 165 11 0 11.4 10.6 09/06/2006 08:40:00 16.3 2.4 22.9 10.7 16 2.4 23.3 11.1 15.9 2.7 24 8.8 330 16 335 165 11.4 0 11.7 11.1 09/06/2006 08:50:00 15.2 1.6 19.5 9.9 15 1.6 19.1 10.7 14.8 1.7 19.5 8.8 326 12 307 165 11.7 0.1 11.9 11.4 09/06/2006 09:00:00 15.6 2.4 22.1 9.9 15.5 2.4 22.9 9.5 14.7 2.7 22.6 8 322 14 336 165 11.9 0.1 12.2 11.4 09/06/2006 09:10:00 15.6 2.4 24.4 9.9 15.5 2.4 24.8 9.5 14.2 2.5 20.6 7.2 318 14 323 165 12.1 0.2 12.5 11.7 09/06/2006 09:20:00 16.5 2.6 25.6 9.1 16.1 2.7 25.6 8.4 14.9 2.3 21 8.8 318 15 282 165 12.4 0 12.7 12.2 09/06/2006 09:30:00 15.8 2.4 24.4 8.8 15.6 2.4 24.8 8 14.8 2.2 24 8.4 320 14 287 165 12.9 0 13 12.7 09/06/2006 09:40:00 16.2 2.5 22.9 10.3 15.9 2.5 22.6 9.9 15 2.5 21 8.8 319 15 307 165 12.8 0 13.3 12.5 09/06/2006 09:50:00 17.8 2 24.8 13 17.7 2 24 13 16.1 2.3 25.6 9.9 310 11 302 165 12.6 0 12.7 12.2 09/06/2006 10:00:00 17.2 2.6 23.3 11.5 17 2.6 22.9 11.5 15.7 2.8 24.4 8.8 313 11 324 165 12.8 0.1 13 12.2 09/06/2006 10:10:00 16.3 2.2 22.9 9.5 16.1 2.3 22.6 9.5 14.6 2.3 21.4 9.1 315 14 307 165 13.3 0 13.5 12.7 09/06/2006 10:20:00 16.3 2.6 22.9 9.9 16 2.6 22.1 9.5 15.1 2.8 22.9 8 317 10 290 165 13.4 0 13.5 13 09/06/2006 10:30:00 18.1 2.8 27.1 11.5 18 2.8 26.3 11.5 16.5 2.8 25.2 8.8 312 12 283 165 13.3 0 13.5 13 09/06/2006 10:40:00 18.4 2.7 26.3 11.8 18.2 2.7 25.6 11.8 16.5 2.6 24.4 10.7 311 11 300 165 13.4 0 13.5 13.3 09/06/2006 10:50:00 17.5 2.5 23.7 9.5 17.4 2.5 24.4 9.5 15.9 2.7 23.7 9.1 310 11 312 165 13.3 0 13.3 13.3 09/06/2006 11:00:00 18.3 2.8 26.3 10.7 18.2 2.8 26.3 10.3 15.8 3.1 24.4 8 308 11 302 165 13.5 0 13.5 13.3 09/06/2006 11:10:00 17.8 2.8 26 13 17.6 2.8 25.2 12.2 16.2 2.9 24.4 9.9 312 11 304 165 13.7 0 14.1 13.5 09/06/2006 11:20:00 17.7 2.5 25.6 11.5 17.6 2.5 25.2 11.5 16.5 2.8 26 9.9 315 9 325 165 13.6 0 13.8 13.3 09/06/2006 11:30:00 18.2 2.3 24.4 10.3 18.1 2.3 25.2 10.7 16.7 2.6 22.6 10.3 315 13 298 165 13.8 0 14.1 13.5 09/06/2006 11:40:00 17.5 2.1 22.6 12.6 17.3 2.1 22.6 12.2 15 2.2 21.8 9.5 308 11 308 165 13.5 0 13.8 13.3 09/06/2006 11:50:00 17 2.1 22.9 11.5 16.8 2.1 22.6 11.5 15 1.9 22.1 9.9 310 9 308 165 13.9 0 14.1 13.3 09/06/2006 12:00:00 17.6 2 22.6 12.6 17.5 2 22.6 12.6 15.5 2.2 22.6 10.3 310 9 316 165 13.6 0 13.8 13.3 09/06/2006 12:10:00 17.8 1.6 22.9 12.6 17.5 1.5 22.9 12.6 16.2 1.8 21.8 10.7 313 9 298 165 13.9 0 14.1 13.5 09/06/2006 12:20:00 19.7 2.2 27.1 15.3 19.4 2.2 27.5 14.9 17.9 2.3 26.3 13 313 8 307 165 14.1 0.1 14.6 13.8 09/06/2006 12:30:00 19.2 1.6 24 14.5 19 1.6 23.7 14.5 17.6 1.9 24 12.6 312 7 311 165 14.1 0.1 14.6 13.8 09/06/2006 12:40:00 19.2 1.7 23.3 14.1 19 1.7 23.3 13.7 18 2 22.6 13 313 7 302 165 13.9 0 14.1 13.3 09/06/2006 12:50:00 17.5 1.9 22.6 12.6 17.4 1.9 22.1 12.2 16 1.8 20.6 9.9 314 8 302 165 13.9 0.1 14.4 13.8 09/06/2006 13:00:00 18.5 1.7 22.9 12.6 18.2 1.7 22.9 12.6 16.2 1.8 20.6 11.8 310 6 301 165 14 0 14.4 13.8 09/06/2006 13:10:00 18.5 1.7 22.9 13.3 18.3 1.7 22.6 13 16.5 1.9 22.1 12.2 310 7 304 165 14.1 0 14.4 13.8 09/06/2006 13:20:00 18.5 2.2 22.9 13.3 18.3 2.2 22.9 13.3 16.8 2.4 22.9 11.5 312 9 313 165 14 0.1 14.4 13.5 09/06/2006 13:30:00 17.7 1.5 22.9 13.7 17.5 1.5 22.9 13.7 16.6 1.8 20.6 11.8 317 9 300 165 13.9 0 14.1 13.5 09/06/2006 13:40:00 16.5 1.7 20.2 12.6 16.3 1.7 20.2 12.2 15.3 1.5 19.1 11.5 315 8 304 165 14.2 0 14.4 13.8 09/06/2006 13:50:00 18 1.9 23.3 11.5 17.8 1.9 23.7 11.8 15.9 2 22.1 9.9 310 9 309 165 14.1 0 14.4 13.5 09/06/2006 14:00:00 17.2 1.8 21.8 13 17 1.8 21.4 13 15.5 1.8 19.9 10.3 311 8 302 165 14.1 0 14.4 13.8 09/06/2006 14:10:00 16.8 1.8 20.6 11.1 16.6 1.8 20.6 11.5 15.3 1.7 21 10.7 312 7 307 165 13.9 0 14.4 13.8 09/06/2006 14:20:00 16.2 1.5 19.9 11.1 16 1.5 19.1 11.1 15 1.6 19.5 10.7 314 8 307 165 13.9 0 14.1 13.5 09/06/2006 14:30:00 16.5 1.2 20.6 13.7 16.2 1.2 20.2 13.3 14.9 1.3 18.3 11.5 311 6 298 165 13.7 0.1 13.8 13.3 09/06/2006 14:40:00 17.2 1.6 21.8 13 17 1.6 21.4 13 16.1 1.8 21 11.8 314 6 319 165 13.7 0 14.1 13.3 09/06/2006 14:50:00 17 1.6 20.6 13 16.8 1.6 20.6 12.6 15.1 1.7 21.8 10.3 312 8 311 165 13.9 0.2 14.1 13.5 09/06/2006 15:00:00 16.8 1.7 21.8 11.1 16.6 1.7 21.8 11.5 15.8 1.7 20.6 10.7 317 7 303 165 14 0.1 14.4 13.5 09/06/2006 15:10:00 16.3 1.5 20.2 12.2 16.1 1.5 20.6 12.6 15.4 1.9 21.4 9.5 317 9 329 165 13.9 0.2 14.4 13.5 09/06/2006 15:20:00 17 1.7 22.6 13.3 16.8 1.7 22.1 12.6 15.1 1.7 21.4 11.1 312 8 319 165 14 0.1 14.4 13.5 09/06/2006 15:30:00 17.3 1.7 21 12.6 17.2 1.7 21 11.8 15.3 1.9 20.6 11.1 312 7 312 165 14 0.3 14.6 13.3 09/06/2006 15:40:00 17.8 1.3 21 13 17.6 1.3 21.4 13 16.3 1.8 20.2 11.1 313 6 310 165 14.8 0.3 15.5 14.1 09/06/2006 15:50:00 18.4 1.7 21.8 13.3 18.1 1.7 21.8 13.7 17.5 1.9 22.1 12.2 314 6 311 165 15.2 0 15.5 15.2 09/06/2006 16:00:00 16.4 1.6 21 12.2 16.2 1.6 20.2 12.6 15.7 1.6 20.2 11.8 316 8 300 165 15.3 0 15.7 15.2 09/06/2006 16:10:00 16.5 1.5 19.9 12.2 16.3 1.5 19.9 12.2 15.5 1.6 19.1 11.5 316 7 312 165 15.5 0 15.7 15.5 09/06/2006 16:20:00 16.5 1.5 19.9 12.6 16.3 1.6 19.9 11.8 15 1.7 19.9 9.1 314 9 301 165 15.5 0.1 15.7 14.9 09/06/2006 16:30:00 16 1.3 19.1 11.8 15.8 1.3 18.7 11.1 14.6 1.8 18.7 9.5 313 8 314 165 15.6 0 15.7 15.2 09/06/2006 16:40:00 15 1.2 18.7 11.8 14.7 1.2 18.3 11.5 14.3 1.5 18.3 10.3 319 8 309 165 15.8 0 16.3 15.5 09/06/2006 16:50:00 16.6 1.5 20.2 12.6 16.4 1.5 20.2 13 15.7 1.5 19.9 10.7 316 8 312 165 15.6 0.1 16.3 15.2 09/06/2006 17:00:00 16.8 1.7 20.6 11.5 16.6 1.7 20.2 11.5 16.1 1.8 19.9 9.9 316 6 318 165 15.4 0.1 15.7 14.6 09/06/2006 17:10:00 15.9 1.5 19.5 11.1 15.7 1.5 19.1 11.5 14.5 1.7 19.1 10.3 314 8 311 165 15.5 0 15.7 15.2 09/06/2006 17:20:00 16 1.7 21.8 11.5 15.9 1.8 21.4 11.1 14.9 1.7 18.7 10.7 315 8 307 165 15.5 0 15.7 15.2 09/06/2006 17:30:00 16.8 1.5 20.6 11.5 16.7 1.5 20.6 11.5 14.5 1.7 19.1 9.9 309 6 310 165 15.6 0 15.7 15.5 09/06/2006 17:40:00 16.5 1.2 19.5 11.5 16.2 1.2 19.5 11.5 15.2 1.7 19.5 9.1 313 7 317 165 15.5 0.1 16 15.2 09/06/2006 17:50:00 16.4 1.5 20.6 13 16.2 1.5 20.6 12.6 14.7 1.7 18.7 10.7 311 6 309 165 15.7 0.1 16 15.5 09/06/2006 18:00:00 15.9 1.3 18.7 12.6 15.7 1.3 18.7 12.6 15.3 1.5 19.5 11.5 316 6 317 165 15.3 0.3 16 14.9 09/06/2006 18:10:00 15.1 1.7 18.3 10.7 14.9 1.7 18.3 10.3 14.3 1.7 18.7 10.3 315 6 313 165 14.4 0.2 14.9 13.8 09/06/2006 18:20:00 15.1 1.6 18.3 10.7 14.9 1.7 18.3 10.7 14.6 1.8 19.5 9.9 319 9 310 165 14.3 0 14.6 13.8 09/06/2006 18:30:00 14.5 1.3 17.9 11.5 14.4 1.3 17.9 11.1 13.8 1.5 17.9 10.7 317 7 312 165 14.7 0.2 15.2 14.1 09/06/2006 18:40:00 14.1 1.1 17.9 10.3 14 1.1 17.9 10.7 13.8 1.4 18.7 9.1 320 8 323 165 14.6 0.1 15.2 14.4 09/06/2006 18:50:00 14.5 1.4 19.5 9.9 14.3 1.4 19.5 9.5 13.8 1.4 17.2 9.5 317 6 313 165 14.1 0.2 14.6 13.3 09/06/2006 19:00:00 15.5 1.5 19.9 11.5 15.3 1.4 19.5 11.5 15.1 1.7 19.5 10.3 322 8 307 165 14 0.1 14.4 13.5 09/06/2006 19:10:00 14.2 1.4 17.6 10.7 14 1.4 17.6 10.7 13.8 1.6 17.9 10.3 321 6 320 165 13.9 0 14.1 13.3 09/06/2006 19:20:00 15.5 1.3 18.3 11.5 15.3 1.3 18.3 11.1 14.6 1.5 17.9 10.3 317 6 319 165 13.7 0 13.8 13 09/06/2006 19:30:00 14.9 1.3 18.3 12.2 14.6 1.3 17.9 11.8 14.2 1.2 18.3 11.1 318 6 304 165 13.8 0 14.1 13.5 09/06/2006 19:40:00 14.1 1.3 17.2 11.1 13.8 1.3 17.2 10.7 13.6 1.3 17.6 9.5 319 6 315 165 13.5 0 13.8 13.3 09/06/2006 19:50:00 13.1 1.1 16.4 10.3 12.8 1.1 16.4 10.3 12.7 1.1 16.1 9.5 320 5 323 165 13.4 0 13.5 13 09/06/2006 20:00:00 13 1.1 15.6 9.1 12.7 1 15.3 9.1 12.2 1.2 15.6 8.4 316 6 315 165 13.1 0 13.3 12.7 09/06/2006 20:10:00 13 1 15.6 10.3 12.7 1 15.6 9.9 12.2 1.1 15.6 9.1 315 6 317 165 12.9 0.1 13.3 12.5 09/06/2006 20:20:00 14.2 0.9 16.4 11.5 13.9 1 16.1 11.1 13.5 1 16.1 9.9 318 6 314 165 12.9 0.1 13 12.5 09/06/2006 20:30:00 14 1.3 17.6 11.1 13.8 1.2 17.6 10.7 12.9 1.5 16.8 8.8 315 6 297 165 12.9 0.1 13.3 12.5 09/06/2006 20:40:00 13.4 1.6 18.7 8.4 13.2 1.6 18.7 8 11.9 1.7 16.4 8.4 312 9 316 165 13 0.1 13.5 12.7 09/06/2006 20:50:00 12.1 1.5 16.1 7.2 12 1.4 16.4 6.8 10.7 1.8 15.3 6.5 314 8 312 165 12.9 0.2 13.3 12.5 09/06/2006 21:00:00 8.7 1.6 12.6 4.9 8.5 1.6 13.3 4.9 7.9 1.4 11.5 4.2 327 15 343 165 12.7 0.1 13 12.2 09/06/2006 21:10:00 10.5 1.9 16.8 5.3 10.3 1.9 16.8 5.7 8.8 1.6 13.3 4.6 309 10 302 165 12.8 0 13 12.2 09/06/2006 21:20:00 12.9 1.3 17.2 9.1 12.7 1.3 16.8 8.8 10.6 1.3 14.9 7.2 307 6 300 165 12.7 0 13 12.5 09/06/2006 21:30:00 13.5 1.3 16.8 8.8 13.3 1.3 16.8 8.8 11.3 1.3 15.3 6.8 309 6 304 165 12.7 0 13 12.5 09/06/2006 21:40:00 14.2 1.3 17.2 11.1 14 1.3 16.8 11.1 12 1.2 15.6 9.1 310 5 319 165 12.7 0 12.7 12.5 09/06/2006 21:50:00 13.5 1.2 16.1 9.9 13.2 1.2 16.1 9.5 11.7 1.4 14.9 7.2 310 5 310 165 12.7 0 13 12.5 09/06/2006 22:00:00 11.6 1.5 16.4 7.6 11.5 1.5 16.4 7.6 10.1 1.3 15.6 7.6 311 8 301 165 12.8 0 13 12.5 09/06/2006 22:10:00 11 1.3 15.3 8 10.8 1.4 15.3 8 9.8 1.3 13.3 4.6 312 8 302 165 12.7 0 13 12.5 09/06/2006 22:20:00 8.8 1.3 13.7 6.5 8.6 1.4 14.9 5.7 8.5 1.3 13.3 5.7 328 9 331 165 12.3 0.1 12.7 11.9 09/06/2006 22:30:00 7.7 1.2 11.5 4.6 7.6 1.3 11.5 4.6 7 1.4 13 3.8 319 17 344 165 12.5 0.1 13 12.2 09/06/2006 22:40:00 8.7 1.2 11.5 5.7 8.5 1.2 11.1 5.7 7.6 1.1 11.1 5.3 311 11 308 165 12.1 0 12.5 11.7 09/06/2006 22:50:00 11.7 1.2 14.9 8 11.7 1.2 14.5 8 8.7 1.1 11.8 6.1 300 6 304 165 11.7 0.2 12.2 11.4 09/06/2006 23:00:00 11.6 1.3 15.6 8.4 11.5 1.2 14.9 8.4 9.3 1.3 14.1 5.7 305 7 307 165 11.5 0.2 11.9 11.1 09/06/2006 23:10:00 12.1 1.5 15.3 8.8 12.1 1.5 14.9 8.4 9.4 1.2 12.6 6.8 304 6 296 165 11.7 0.2 11.9 11.4 09/06/2006 23:20:00 10.8 1.5 14.9 7.2 10.8 1.5 14.5 7.2 8.6 1.5 14.5 4.9 300 7 290 165 11.9 0.1 12.2 11.4 09/06/2006 23:30:00 11 1.6 13.7 5.3 11 1.5 14.1 5.3 8.8 1.5 11.8 3.4 296 6 291 165 11.7 0.2 12.2 11.4 09/06/2006 23:40:00 9.7 1.7 13.3 4.9 9.7 1.7 13.3 5.3 7.7 1.6 12.6 4.2 295 7 296 165 11.5 0.1 11.9 11.1 09/06/2006 23:50:00 10.1 1 13 7.2 10.2 1 13 7.2 7.6 1 10.7 4.9 301 5 300 165 11.2 0.3 11.7 10.9 09/07/2006 00:00:00 9.7 1.1 12.6 6.8 9.7 1.2 12.2 6.1 7.2 1 9.5 4.2 303 4 302 165 11.2 0.1 11.7 10.9 09/07/2006 00:10:00 8.6 1.5 11.8 4.6 8.5 1.5 11.8 4.6 6.8 1.2 9.5 3.8 303 7 297 165 11.2 0 11.4 10.9 09/07/2006 00:20:00 7.2 1 8.8 4.2 7.1 1 8.8 4.6 5.8 0.8 9.1 3.8 305 7 302 165 11.4 0 11.7 11.1 09/07/2006 00:30:00 7.5 1 9.5 5.3 7.5 0.9 9.5 5.3 6 0.9 8.8 4.2 301 7 292 165 11.6 0 11.9 11.4 09/07/2006 00:40:00 7.7 0.8 9.9 5.3 7.7 0.9 9.5 5.7 6.1 0.8 8 4.2 305 6 302 165 11.6 0 11.9 11.1 09/07/2006 00:50:00 8.4 1 10.3 5.7 8.3 1 10.3 5.3 6.4 0.9 8.8 4.2 302 6 305 165 11.7 0 11.9 11.1 09/07/2006 01:00:00 7.2 1.6 10.7 4.2 7.1 1.6 10.7 3.8 5.9 1.4 9.1 2.3 305 9 304 165 11.7 0 11.9 11.4 09/07/2006 01:10:00 4.8 1.1 8.4 2.3 4.9 1.1 8.4 2.3 4.3 1 7.6 2.3 295 12 287 165 11.7 0.1 11.9 11.4 09/07/2006 01:20:00 4.4 1.2 8 1.1 4.5 1.2 7.6 0.7 4.3 1 7.2 2.3 298 19 301 165 11.9 0.1 12.2 11.7 09/07/2006 01:30:00 4.4 1.1 7.6 1.9 4.4 1.1 7.6 1.1 4 1 7.6 1.5 307 17 295 165 12.1 0 12.2 11.7 09/07/2006 01:40:00 6.4 1.2 9.1 3 6.4 1.2 8.8 3 5.3 1.1 9.1 3 300 8 289 165 11.9 0 12.2 11.7 09/07/2006 01:50:00 7.6 0.9 10.3 5.7 7.6 0.9 10.3 5.7 6.7 1.3 9.5 3.8 294 7 289 165 11.7 0 11.9 11.7 09/07/2006 02:00:00 7.5 0.8 10.7 4.9 7.6 0.8 10.3 5.3 7.2 1 11.1 3.8 291 5 289 165 11.7 0 11.9 11.4 09/07/2006 02:10:00 8.4 0.8 10.3 6.5 8.4 0.8 10.3 6.1 7.3 1.2 10.3 4.2 291 5 290 165 11.7 0 11.9 11.7 09/07/2006 02:20:00 8.8 0.5 9.9 6.8 8.8 0.5 9.9 6.8 6.4 0.6 8.8 4.9 301 3 297 165 11.5 0 11.7 11.1 09/07/2006 02:30:00 8.6 0.6 10.3 7.2 8.6 0.7 10.3 7.2 6.3 0.6 8.4 4.6 301 3 299 165 11.6 0 11.9 11.4 09/07/2006 02:40:00 7.5 1.2 9.5 4.6 7.4 1.2 9.9 4.2 6 0.8 8 3.8 306 6 298 165 11.6 0 11.9 11.4 09/07/2006 02:50:00 4.7 1 7.6 2.6 4.6 1 7.6 2.6 4.2 0.7 6.8 3 309 7 313 165 11.4 0 11.7 11.1 09/07/2006 03:00:00 3.3 0.7 5.3 1.9 3.3 0.7 4.9 1.5 3 0.5 4.6 1.9 302 9 296 165 11.7 0.2 12.2 11.1 09/07/2006 03:10:00 2.7 0.8 4.2 0.4 2.7 0.8 4.2 0.4 2.6 0.6 3.8 1.1 301 8 293 165 11.9 0.1 12.2 11.7 09/07/2006 03:20:00 0.6 0.3 1.5 0.4 0.4 0.2 1.1 0.4 0.8 0.5 1.9 0.4 329 79 291 165 12.1 0.1 12.5 11.7 09/07/2006 03:30:00 2 0.5 2.6 0.4 1.9 0.5 2.6 0.4 2.4 0.3 3 1.5 139 4 135 165 11.8 0.4 12.5 11.1 09/07/2006 03:40:00 0.6 0.3 1.5 0.4 0.5 0.2 1.5 0.4 1.3 0.3 1.9 0.7 145 7 136 165 11.6 0.3 12.2 11.1 09/07/2006 03:50:00 0.8 0.5 2.3 0.4 0.7 0.5 2.3 0.4 1.1 0.5 1.9 0.4 216 53 282 165 12.1 0 12.5 11.9 09/07/2006 04:00:00 2.9 0.7 3.8 1.1 3 0.7 4.2 1.1 3.2 0.6 4.6 1.1 277 4 275 165 12 0.1 12.2 11.7 09/07/2006 04:10:00 2.9 0.4 3.4 1.9 2.9 0.4 3.4 1.9 2.9 0.5 3.8 1.5 288 4 288 165 11.9 0 12.2 11.7 09/07/2006 04:20:00 2 0.5 3 0.7 2 0.5 3 0.7 2.5 0.4 3.4 1.1 281 7 291 165 12.1 0 12.5 11.9 09/07/2006 04:30:00 2.7 0.4 3.4 1.9 2.6 0.4 3.4 1.9 2.3 0.3 3 1.5 296 4 297 165 12.3 0 12.5 11.9 09/07/2006 04:40:00 2.2 0.4 3.4 1.5 2.2 0.4 3.4 1.5 2.4 0.3 3 1.5 294 4 298 165 12.3 0 12.5 11.9 09/07/2006 04:50:00 1.4 0.4 2.3 0.4 1.6 0.3 2.3 0.7 2 0.2 2.6 1.5 276 9 286 165 12.6 0 12.7 12.2 09/07/2006 05:00:00 1.4 0.2 2.3 1.1 1.5 0.2 2.3 1.1 2 0.2 2.3 1.5 227 11 242 165 12.3 0 12.5 11.7 09/07/2006 05:10:00 1 0.3 2.3 0.4 1.1 0.3 1.9 0.4 1.8 0.3 2.6 0.7 243 24 276 165 12.4 0.1 12.7 11.9 09/07/2006 05:20:00 1.1 0.3 1.9 0.4 1.1 0.4 1.9 0.4 1.5 0.3 2.3 0.7 287 15 297 165 12.5 0 12.7 12.2 09/07/2006 05:30:00 0.6 0.2 1.1 0.4 0.6 0.3 1.1 0.4 1.3 0.4 1.9 0.4 263 6 257 165 12.7 0 12.7 12.5 09/07/2006 05:40:00 0.5 0.2 1.1 0.4 0.4 0.2 1.1 0.4 1.2 0.3 1.9 0.7 276 11 268 165 12.6 0 12.7 12.2 09/07/2006 05:50:00 0.5 0.2 1.1 0.4 0.4 0.2 1.1 0.4 1.2 0.2 1.5 0.7 303 7 292 165 12.1 0.3 12.7 11.4 09/07/2006 06:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.5 0.2 1.1 0.4 307 0 165 165 11.2 0.2 11.7 10.9 09/07/2006 06:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.9 0.5 1.5 0.4 17 82 165 165 10.9 0.2 11.4 10.6 09/07/2006 06:20:00 1.2 0.4 1.9 0.4 0.9 0.4 1.5 0.4 1.6 0.2 1.9 1.1 140 9 145 165 10.9 0.1 11.4 10.6 09/07/2006 06:30:00 1.3 0.2 1.9 0.7 1.2 0.2 1.5 0.7 1.7 0.2 2.3 1.1 136 2 141 165 11.4 0.2 11.9 10.9 09/07/2006 06:40:00 0.7 0.3 1.5 0.4 0.6 0.3 1.1 0.4 1.2 0.2 1.9 0.7 138 2 140 165 12.1 0.2 12.5 11.4 09/07/2006 06:50:00 0.6 0.3 1.1 0.4 0.5 0.2 1.1 0.4 1.2 0.3 1.9 0.7 152 6 145 165 12.6 0 12.7 12.2 09/07/2006 07:00:00 0.5 0.2 1.1 0.4 0.4 0.1 0.7 0.4 1 0.3 1.5 0.4 160 3 157 165 12.7 0 13 12.2 09/07/2006 07:10:00 0.4 0.2 1.5 0.4 0.4 0.1 1.1 0.4 0.7 0.2 1.1 0.4 178 9 183 165 12.9 0.3 13.5 12.2 09/07/2006 07:20:00 2.1 0.6 3.4 0.4 2 0.6 3.4 0.4 2.2 0.6 3.4 0.4 160 13 165 165 13.5 0 13.8 13.3 09/07/2006 07:30:00 1.6 0.3 2.6 0.7 1.5 0.4 2.3 0.7 2 0.3 2.6 1.5 167 4 176 165 13.7 0 13.8 13.5 09/07/2006 07:40:00 1.7 0.5 3 0.7 1.7 0.5 3 0.7 2.1 0.3 3 1.5 167 5 164 165 13.3 0.3 13.8 12.7 09/07/2006 07:50:00 2.8 0.8 4.6 1.1 2.7 0.8 4.6 0.7 3.1 0.6 4.6 1.5 174 7 183 165 13.1 0 13.3 12.7 09/07/2006 08:00:00 3.6 0.4 4.6 2.6 3.5 0.4 4.6 2.3 3.9 0.4 4.9 3 173 10 173 165 12.9 0 13 12.5 09/07/2006 08:10:00 3.8 0.4 4.6 3 3.7 0.3 4.6 3 4.1 0.4 4.6 3 170 7 165 165 12.4 0 12.7 12.2 09/07/2006 08:20:00 4.1 0.5 5.3 3 4 0.5 5.3 2.6 4.2 0.4 5.3 3.4 170 9 165 165 12 0.1 12.5 11.9 09/07/2006 08:30:00 4.4 0.6 6.1 3 4.4 0.6 6.1 3 4.7 0.5 6.1 3.4 168 7 165 165 12.3 0.3 13 11.9 09/07/2006 08:40:00 5.3 0.5 6.1 4.2 5.1 0.4 6.1 3.8 5.4 0.4 6.5 4.6 165 12 165 165 13.1 0 13.3 12.7 09/07/2006 08:50:00 5.5 0.7 6.8 3.8 5.3 0.7 6.8 3.8 5.6 0.6 6.8 4.2 164 12 167 165 13.9 0.4 14.6 13 09/07/2006 09:00:00 6.3 0.7 7.6 4.2 6.1 0.6 7.2 4.2 6.3 0.8 7.6 4.2 162 5 159 165 13.3 0.6 14.6 12.5 09/07/2006 09:10:00 5.5 0.8 8 3.4 5.3 0.8 7.2 3.4 5.5 0.7 7.6 3.8 166 6 167 165 12.3 0.1 12.5 11.7 09/07/2006 09:20:00 5.4 0.6 6.5 4.2 5.2 0.5 6.5 3.8 5.5 0.4 6.5 4.2 163 5 162 165 12.3 0.1 12.5 11.9 09/07/2006 09:30:00 5 0.7 6.5 3 4.9 0.7 6.1 3 5.1 0.6 6.5 3.8 161 6 162 165 12.5 0 12.7 11.9 09/07/2006 09:40:00 5.1 0.7 7.2 3 5 0.7 6.8 3 5.2 0.6 6.8 3.8 160 9 147 165 12.6 0 12.7 11.9 09/07/2006 09:50:00 5 0.8 6.5 1.9 5 0.7 6.5 2.3 5.1 0.7 6.8 3 152 9 158 165 12.6 0 12.7 11.9 09/07/2006 10:00:00 6.2 0.9 8.4 4.2 6.1 0.9 8 4.2 6.3 0.8 8.4 4.2 150 9 145 165 12.5 0.2 12.7 11.7 09/07/2006 10:10:00 6.1 1 8.4 3 6 1 8 3 6.2 0.8 7.6 3.8 151 6 147 165 12.4 0.1 12.5 11.7 09/07/2006 10:20:00 5.8 0.9 7.6 3.8 5.7 0.9 7.2 4.2 5.8 0.9 8 3.8 148 8 153 165 12.5 0 12.7 11.9 09/07/2006 10:30:00 6.4 0.6 8 4.2 6.2 0.6 8 4.2 6.3 0.6 7.6 4.6 146 7 139 165 12.6 0 12.7 12.2 09/07/2006 10:40:00 6.4 0.8 8 3.8 6.3 0.8 7.6 3 6.5 0.7 8 4.2 142 8 136 165 12.7 0 12.7 12.2 09/07/2006 10:50:00 6.4 0.6 8 4.6 6.3 0.6 7.6 4.6 6.3 0.7 7.6 4.6 143 6 138 165 12.7 0 13 11.9 09/07/2006 11:00:00 5.8 0.5 6.8 4.2 5.8 0.5 6.8 4.2 5.8 0.5 7.2 3.8 140 7 132 165 12.4 0.1 12.7 11.9 09/07/2006 11:10:00 5.9 0.4 6.8 4.2 5.9 0.4 7.2 4.6 5.9 0.4 6.8 4.6 137 5 135 165 12.6 0 13 11.9 09/07/2006 11:20:00 5.5 0.6 7.2 3.8 5.4 0.6 7.2 4.2 5.6 0.6 7.2 4.6 135 10 137 165 12.8 0.1 13 12.5 09/07/2006 11:30:00 5.4 0.4 6.8 4.6 5.3 0.4 6.8 4.2 5.5 0.5 7.2 4.2 143 5 147 165 12.8 0 13 12.5 09/07/2006 11:40:00 4.3 0.4 5.3 3.4 4.2 0.4 4.9 3.4 4.4 0.4 5.7 3 135 5 135 165 12.4 0 12.7 12.2 09/07/2006 11:50:00 3.6 0.3 4.6 3 3.5 0.3 4.6 2.6 3.8 0.3 4.6 3 134 6 137 165 12.4 0 12.7 11.9 09/07/2006 12:00:00 4.3 0.3 4.9 3 4.1 0.3 4.9 3 4.5 0.4 5.3 3.8 144 6 136 165 12.5 0 12.7 12.2 09/07/2006 12:10:00 4.9 0.4 6.1 3.4 4.7 0.4 5.7 3.4 5.1 0.4 6.1 3.8 147 7 142 165 13.1 0.3 13.5 12.2 09/07/2006 12:20:00 5.1 0.5 6.5 3.8 5 0.5 6.5 3.8 5.2 0.5 6.8 3.8 138 9 123 165 12.9 0.4 13.5 12.5 09/07/2006 12:30:00 6 0.7 8.4 4.2 5.9 0.7 8.4 4.2 6.2 0.7 8.4 4.6 138 8 141 165 12.1 0.1 12.5 11.7 09/07/2006 12:40:00 6.3 1 8.4 3 6.2 1.1 8.4 3 6.4 1.1 8.8 2.6 147 11 146 165 11.7 0.1 12.2 11.4 09/07/2006 12:50:00 7.6 0.8 9.5 5.7 7.4 0.8 9.5 5.7 7.8 0.8 9.5 6.1 162 7 170 165 11.6 0 11.9 11.1 09/07/2006 13:00:00 9.4 0.6 10.7 7.6 9.1 0.6 10.3 7.2 9.4 0.8 11.1 7.2 171 5 166 165 11.5 0 11.7 11.1 09/07/2006 13:10:00 10.1 0.5 11.1 8.4 9.7 0.4 10.7 8.4 10.2 0.6 11.1 8.4 168 9 178 165 11.4 0 11.7 11.1 09/07/2006 13:20:00 10 0.7 11.5 8 9.7 0.6 11.1 8 10 0.8 11.8 8 169 9 304 165 11.2 0 11.4 10.9 09/07/2006 13:30:00 10.3 0.8 11.8 8 10 0.7 11.5 8 10.2 0.9 12.2 7.6 166 13 159 165 11 0 11.4 10.9 09/07/2006 13:40:00 9.7 0.8 11.1 7.2 9.5 0.7 11.1 7.2 9.6 1 11.5 7.2 167 15 173 165 11.1 0 11.1 10.9 09/07/2006 13:50:00 9.7 0.5 11.1 8 9.5 0.5 10.7 7.6 9.9 0.5 11.1 8.4 167 10 165 165 10.9 0 11.1 10.6 09/07/2006 14:00:00 9.4 0.5 10.7 8 9.1 0.4 9.9 8 9.4 0.5 10.7 7.6 167 4 158 165 10.7 0.1 11.1 10.1 09/07/2006 14:10:00 9.1 0.5 10.7 7.6 8.8 0.5 10.7 7.6 9.2 0.6 10.3 7.2 166 9 161 165 10.7 0.1 10.9 10.3 09/07/2006 14:20:00 9 0.8 10.7 6.1 8.7 0.7 9.9 6.1 8.9 0.8 10.7 6.5 166 8 166 165 10.7 0 10.9 10.6 09/07/2006 14:30:00 9.9 0.7 11.5 6.8 9.6 0.6 11.1 7.6 10 0.8 11.8 8 167 7 169 165 10.5 0 11.1 10.3 09/07/2006 14:40:00 10.2 0.5 11.5 8.4 9.9 0.5 11.1 8 10.2 0.6 11.5 8.4 166 8 165 165 10.4 0 10.9 10.1 09/07/2006 14:50:00 10.5 0.6 11.8 8.4 10.1 0.5 11.5 8 10.5 0.7 11.8 8.4 167 12 165 165 10.2 0 10.6 9.8 09/07/2006 15:00:00 10.5 0.6 11.5 8.8 10.2 0.5 11.1 8.8 10.6 0.7 12.2 8.8 166 3 171 165 10.1 0.1 10.6 9.8 09/07/2006 15:10:00 10.4 0.5 11.5 9.1 10.1 0.5 11.1 8.8 10.5 0.6 11.8 9.1 167 6 164 165 10.2 0.1 10.6 9.8 09/07/2006 15:20:00 10.3 0.7 11.8 8.4 10.1 0.6 11.5 8.4 10.3 0.7 12.2 8.4 167 4 165 165 10.2 0.1 10.6 9.8 09/07/2006 15:30:00 10.1 0.7 11.5 8 9.9 0.6 11.5 8 9.9 0.8 11.5 8 164 15 164 165 10.3 0 10.6 9.8 09/07/2006 15:40:00 9.3 0.4 10.3 8 9.1 0.4 9.9 8 9.2 0.5 10.3 7.6 166 10 167 165 10.3 0 10.6 9.8 09/07/2006 15:50:00 8.1 0.6 9.1 6.5 8 0.6 9.1 6.5 8.4 0.5 9.5 6.8 162 6 164 165 10.3 0 10.9 9.8 09/07/2006 16:00:00 8 0.4 8.8 6.8 8 0.5 9.1 6.8 8.1 0.5 9.1 6.5 149 3 149 165 10.3 0 10.6 10.1 09/07/2006 16:10:00 8.9 0.6 9.9 6.8 8.9 0.6 9.9 6.8 8.9 0.6 10.3 6.8 150 3 150 165 10.3 0 10.6 10.1 09/07/2006 16:20:00 9.4 0.6 10.7 8 9.4 0.6 10.7 7.6 9.2 0.7 10.7 6.8 145 4 146 165 10.3 0 10.6 10.1 09/07/2006 16:30:00 9.6 0.5 10.7 7.2 9.6 0.5 10.7 7.6 9.4 0.6 10.7 7.2 144 3 136 165 10.3 0 10.6 9.8 09/07/2006 16:40:00 9.3 0.7 11.5 7.2 9.3 0.7 11.1 7.2 8.9 0.9 11.5 6.5 144 5 147 165 10.4 0 10.9 10.3 09/07/2006 16:50:00 9.2 0.6 10.7 7.6 9.3 0.6 10.7 7.6 8.9 0.9 10.7 6.1 143 5 133 165 10.5 0 10.9 10.3 09/07/2006 17:00:00 9.3 0.7 10.7 6.5 9.3 0.7 10.7 6.5 9 0.8 10.7 5.7 143 4 145 165 10.5 0 10.9 10.3 09/07/2006 17:10:00 9.1 0.8 10.7 6.1 9.1 0.8 10.7 6.5 8.8 0.8 10.3 5.7 144 4 143 165 10.6 0 10.9 10.3 09/07/2006 17:20:00 8.9 0.6 10.3 7.2 8.9 0.6 10.3 7.6 8.4 0.7 9.9 6.5 143 4 150 165 10.7 0 10.9 10.6 09/07/2006 17:30:00 9.3 0.6 10.7 7.6 9.3 0.6 10.7 7.6 8.9 0.8 10.3 6.1 142 4 133 165 10.7 0 10.9 10.6 09/07/2006 17:40:00 9 0.6 10.3 7.2 9 0.6 10.7 7.2 8.6 0.6 9.9 6.8 143 4 144 165 10.7 0.1 10.9 10.3 09/07/2006 17:50:00 8.4 0.6 9.9 6.8 8.4 0.6 9.9 6.8 8.2 0.7 10.3 6.5 145 4 149 165 10.7 0.1 10.9 10.3 09/07/2006 18:00:00 8.1 0.5 9.1 6.5 8 0.6 9.1 6.5 8 0.6 9.5 6.5 147 3 149 165 10.8 0 10.9 10.9 09/07/2006 18:10:00 8 0.3 8.8 7.2 7.9 0.4 9.1 6.8 8 0.5 9.1 6.5 149 2 146 165 10.9 0 11.1 10.6 09/07/2006 18:20:00 7.5 0.4 8 6.5 7.4 0.3 8 6.5 7.4 0.4 8.4 6.1 150 2 151 165 10.9 0 11.1 10.6 09/07/2006 18:30:00 7.8 0.5 9.1 6.1 7.6 0.5 8.8 5.7 7.8 0.5 8.8 6.5 154 3 151 165 10.9 0 11.1 10.6 09/07/2006 18:40:00 8.7 0.6 9.9 7.2 8.6 0.6 9.9 6.8 8.7 0.5 9.9 6.5 152 3 153 165 10.9 0 11.1 10.9 09/07/2006 18:50:00 8.3 0.5 9.5 6.5 8.2 0.5 9.9 6.8 8.3 0.5 9.9 6.5 152 3 150 165 10.9 0 11.1 10.9 09/07/2006 19:00:00 9 0.5 10.3 8 8.9 0.5 10.3 7.6 9 0.4 10.3 8 153 2 151 165 10.9 0 11.1 10.9 09/07/2006 19:10:00 10.5 1.1 13 8.4 10.4 1 13 8.4 10.4 1.1 13.3 8 156 4 156 165 11 0 11.1 10.9 09/07/2006 19:20:00 11.1 0.8 13.7 8.4 11 0.8 13.7 8.4 11.1 0.8 13.3 8.4 156 4 154 165 10.9 0 11.1 10.9 09/07/2006 19:30:00 11.7 0.9 14.5 9.5 11.6 0.8 14.1 9.5 11.8 0.9 14.1 9.5 158 5 153 165 10.9 0 11.1 10.9 09/07/2006 19:40:00 11.9 1.1 14.5 9.1 11.8 1 14.1 9.1 11.9 1.1 14.1 9.1 160 12 154 165 10.9 0 11.1 10.9 09/07/2006 19:50:00 12.6 0.7 14.5 10.3 12.4 0.7 14.5 10.3 12.7 0.9 14.5 9.9 165 6 164 165 10.9 0 11.1 10.9 09/07/2006 20:00:00 13.5 1.3 16.4 10.3 13.3 1.3 16.1 9.9 13.4 1.4 17.2 9.9 166 13 171 165 10.8 0 11.1 10.6 09/07/2006 20:10:00 14.6 0.9 16.8 11.8 14.4 0.8 16.8 11.8 14.4 1 16.4 11.5 164 8 164 165 10.7 0 11.1 10.6 09/07/2006 20:20:00 14.1 1.1 16.8 11.1 14 1 16.4 11.1 14.2 1.1 17.2 11.1 164 14 165 165 10.7 0.1 10.9 10.6 09/07/2006 20:30:00 12.9 1.1 16.1 10.3 12.7 1 15.6 10.7 12.9 1.1 16.8 10.3 165 13 176 165 10.7 0.1 10.9 10.3 09/07/2006 20:40:00 12.4 1 14.5 9.5 12.3 1 14.5 9.1 12.5 1.1 15.3 9.1 167 18 165 165 10.6 0.1 11.1 10.3 09/07/2006 20:50:00 11.5 0.9 13.3 9.1 11.5 0.9 13.7 9.1 11.5 1 13.7 8.4 164 15 166 165 10.5 0 10.9 10.3 09/07/2006 21:00:00 13.1 1.3 15.6 9.9 12.9 1.2 15.3 9.5 13 1.1 15.6 9.9 168 17 165 165 10.5 0 10.9 10.3 09/07/2006 21:10:00 14 0.8 15.6 11.5 13.9 0.8 15.3 11.8 14.1 0.9 16.1 10.7 163 5 164 165 10.4 0 10.9 10.3 09/07/2006 21:20:00 14.1 0.6 15.6 12.2 13.9 0.6 15.6 12.2 14.1 0.8 15.6 11.5 166 9 166 165 10.4 0 10.9 10.3 09/07/2006 21:30:00 13.9 0.8 16.1 11.5 13.8 0.8 16.1 11.8 13.9 0.9 16.4 11.8 163 17 170 165 10.4 0 10.9 10.1 09/07/2006 21:40:00 14 0.7 15.3 11.8 13.9 0.7 15.3 11.8 14 0.8 15.6 11.1 163 12 165 165 10.4 0 10.6 10.3 09/07/2006 21:50:00 14 1 16.1 11.1 13.9 1 15.6 11.5 14.1 0.9 16.1 11.5 162 10 159 165 10.4 0 10.9 10.3 09/07/2006 22:00:00 13.6 0.9 15.3 9.9 13.4 0.8 14.9 10.7 13.7 0.9 15.3 10.7 165 9 165 165 10.4 0 10.9 10.3 09/07/2006 22:10:00 10.6 1.3 13.3 8 10.6 1.3 13.3 8 10.6 1.5 13.3 6.8 163 6 168 165 10.5 0 10.9 10.3 09/07/2006 22:20:00 10.9 0.8 13.3 9.1 10.7 0.8 13.3 8.8 10.9 0.8 13.3 8.4 164 10 165 165 10.5 0 10.9 10.3 09/07/2006 22:30:00 13.1 1.6 16.1 7.2 12.9 1.5 15.6 7.6 13.4 1.6 16.4 7.2 169 6 164 165 10.5 0 10.9 10.3 09/07/2006 22:40:00 12.1 1.3 15.3 8.8 11.8 1.2 14.9 8.8 12 1.4 15.3 8.4 169 7 169 165 10.6 0 11.1 10.3 09/07/2006 22:50:00 11.1 0.7 12.6 9.5 11 0.6 12.6 9.5 11.1 0.8 13 8 166 4 174 165 10.6 0 10.9 10.3 09/07/2006 23:00:00 10.7 1.5 14.9 7.6 10.7 1.4 14.5 7.6 10.5 1.6 14.1 6.8 160 5 164 165 10.6 0 11.1 10.3 09/07/2006 23:10:00 10 0.8 11.8 7.6 10 0.8 12.2 8 10 0.6 11.5 8.4 161 3 162 165 10.7 0 10.9 10.3 09/07/2006 23:20:00 10.6 1 13 8.8 10.5 0.9 13 8.8 10.7 1 13 8.4 159 5 154 165 10.7 0.1 10.9 10.3 09/07/2006 23:30:00 11.6 0.9 14.1 9.1 11.5 0.9 13.7 9.1 11.8 0.9 14.5 8.8 161 5 162 165 10.7 0 11.1 10.3 09/07/2006 23:40:00 12.2 0.9 14.9 9.9 12.1 0.8 14.5 9.9 12.1 1 14.1 9.1 162 6 152 165 10.7 0 11.1 10.3 09/07/2006 23:50:00 11.8 0.9 14.1 9.1 11.6 0.8 13.7 9.5 11.6 1 14.1 8.8 161 7 163 165 10.7 0 11.1 10.6 09/08/2006 00:00:00 12.3 0.9 14.5 9.9 12.2 0.8 14.1 10.3 12.2 0.9 14.9 9.5 162 7 159 165 10.8 0 11.1 10.6 09/08/2006 00:10:00 13 1 15.6 10.3 12.9 1 15.6 10.7 12.6 1.1 15.6 9.9 162 5 165 165 10.9 0 11.1 10.6 09/08/2006 00:20:00 15.6 1 17.9 12.2 15.4 1 17.6 12.2 15.3 1.1 17.9 11.1 166 17 165 165 10.9 0 11.1 10.6 09/08/2006 00:30:00 17.2 0.7 18.7 15.3 17 0.7 18.3 14.5 17.1 0.8 18.7 14.9 166 12 166 165 10.9 0 11.4 10.6 09/08/2006 00:40:00 18 1.2 20.6 14.9 17.7 1.1 20.2 14.9 17.8 1.4 20.6 12.6 166 12 165 165 10.9 0 11.1 10.6 09/08/2006 00:50:00 18.7 0.7 20.6 16.8 18.3 0.7 19.9 16.8 18.6 0.8 20.2 16.1 166 10 165 165 10.9 0 11.1 10.6 09/08/2006 01:00:00 16.7 0.7 18.3 14.5 16.5 0.8 18.3 14.5 16.7 0.9 18.7 14.5 168 22 165 165 10.9 0 11.1 10.6 09/08/2006 01:10:00 15.7 0.5 16.8 14.1 15.4 0.5 16.4 13.7 15.7 0.5 16.8 13.7 167 15 164 165 10.9 0 11.1 10.9 09/08/2006 01:20:00 14.6 0.5 15.6 13 14.4 0.5 15.6 12.6 14.8 0.6 16.1 13.3 165 17 164 165 10.9 0 11.1 10.3 09/08/2006 01:30:00 13.5 0.5 14.9 12.2 13.3 0.5 14.5 11.8 13.6 0.6 15.3 12.2 163 12 164 165 10.9 0 11.1 10.6 09/08/2006 01:40:00 12.2 0.7 14.9 10.3 12 0.7 14.5 10.3 12.4 0.6 13.7 11.1 162 6 173 165 11 0 11.1 10.6 09/08/2006 01:50:00 11.6 0.6 13 9.9 11.4 0.5 13 10.3 11.9 0.6 13.7 9.9 161 4 162 165 11 0 11.1 10.9 09/08/2006 02:00:00 11.3 0.7 13 9.5 11.2 0.7 13 9.1 11.4 0.8 13.3 9.1 159 4 158 165 11.1 0 11.1 10.9 09/08/2006 02:10:00 11.9 0.8 14.1 9.5 11.7 0.8 13.7 9.1 11.9 0.8 14.1 9.5 162 8 159 165 11.1 0 11.4 10.9 09/08/2006 02:20:00 13.1 1 15.6 10.7 13 1 15.3 10.3 13.2 1 16.1 10.3 161 6 165 165 11.1 0 11.4 10.9 09/08/2006 02:30:00 12.4 1 15.6 10.3 12.3 1 15.3 9.9 12.4 1 15.3 10.3 161 5 162 165 11.1 0 11.4 10.9 09/08/2006 02:40:00 13.2 1.2 16.4 10.3 13.1 1.1 16.1 9.9 13.3 1.2 15.6 9.9 162 9 165 165 11.1 0 11.4 10.9 09/08/2006 02:50:00 14.3 1.1 16.8 11.5 14 1 16.4 11.5 14.3 1.2 16.8 11.1 165 7 163 165 11.1 0 11.4 10.9 09/08/2006 03:00:00 14.2 0.8 16.1 11.1 14 0.8 15.6 11.5 14 0.8 16.1 11.5 166 15 166 165 11.1 0 11.4 10.9 09/08/2006 03:10:00 14.3 1 17.2 11.8 14.1 0.9 16.8 11.5 14.2 1 16.8 11.5 163 15 167 165 11.2 0 11.4 10.9 09/08/2006 03:20:00 14 0.9 16.1 10.7 13.8 0.8 16.1 10.7 14 0.9 16.1 11.5 166 18 164 165 11.3 0 11.4 10.9 09/08/2006 03:30:00 14.8 1.3 18.7 11.8 14.6 1.3 18.3 11.8 14.9 1.4 19.1 11.8 167 13 177 165 11.2 0 11.4 11.1 09/08/2006 03:40:00 16.5 1.2 19.9 13 16.2 1.2 19.5 13 16.4 1.3 19.5 12.6 167 12 162 165 11.1 0 11.4 10.9 09/08/2006 03:50:00 15.7 1.1 18.3 13 15.5 1 17.9 12.6 15.7 1.1 18.3 12.2 167 14 165 165 11.1 0 11.4 10.9 09/08/2006 04:00:00 15.5 1.3 18.7 12.6 15.3 1.2 18.7 12.6 15.5 1.4 19.5 11.8 167 11 171 165 11 0 11.1 10.9 09/08/2006 04:10:00 16.8 1.2 19.9 13.7 16.4 1.1 19.9 13.7 16.7 1.3 20.2 13 168 16 170 165 10.9 0 11.1 10.6 09/08/2006 04:20:00 16.5 1 19.5 13 16.3 1 19.1 13 16.6 1 18.7 12.2 165 11 164 165 11 0 11.1 10.9 09/08/2006 04:30:00 16.1 1 18.3 13.7 15.9 1 18.3 13.3 16.2 1.1 18.7 12.2 166 16 164 165 11 0 11.1 10.9 09/08/2006 04:40:00 15.5 1.1 17.9 12.6 15.3 1 17.9 12.2 15.5 1.2 17.9 11.8 166 5 169 165 10.9 0.1 11.1 10.6 09/08/2006 04:50:00 15.9 1.1 18.7 13 15.7 1.1 18.7 12.6 16 1.2 19.1 13 166 13 168 165 10.7 0.1 10.9 10.3 09/08/2006 05:00:00 16.1 1.2 19.1 13 15.8 1.1 18.7 13 16.1 1.2 19.1 12.6 166 17 162 165 10.7 0.1 10.9 10.3 09/08/2006 05:10:00 16.9 0.9 18.7 14.5 16.7 0.8 18.3 14.1 16.9 1 18.7 13.7 166 15 165 165 10.6 0.1 11.1 10.3 09/08/2006 05:20:00 15.9 1 18.3 12.2 15.7 1 18.3 12.2 15.7 1.1 17.9 11.8 167 16 160 165 10.6 0.2 10.9 10.3 09/08/2006 05:30:00 15.1 1.2 18.3 11.5 14.9 1.1 17.6 11.5 14.9 1.4 17.9 11.1 168 19 165 165 10.7 0.1 11.1 10.3 09/08/2006 05:40:00 14.2 1 16.8 11.5 13.9 0.9 16.8 11.5 14 1.2 17.2 10.3 167 11 170 165 10.7 0.1 11.1 10.3 09/08/2006 05:50:00 15.6 1.1 18.7 13 15.3 1 18.3 13 15.7 1.2 18.7 11.8 166 4 160 165 10.7 0.1 10.9 10.3 09/08/2006 06:00:00 14.4 0.8 16.4 12.6 14.1 0.7 16.1 12.2 14.4 0.8 16.4 11.5 168 17 168 165 10.7 0.1 10.9 10.3 09/08/2006 06:10:00 14.9 1 17.6 11.5 14.6 0.9 16.8 11.5 14.8 1.1 17.6 11.5 165 11 168 165 10.6 0.2 10.9 10.1 09/08/2006 06:20:00 13.5 1.1 16.1 10.7 13.4 1 16.1 10.7 13.7 1.2 16.1 10.7 165 17 165 165 10.4 0 11.1 9.8 09/08/2006 06:30:00 12.5 0.8 14.9 10.3 12.4 0.8 14.9 10.3 12.6 1 15.6 8.4 167 20 163 165 10.4 0 10.9 9.8 09/08/2006 06:40:00 12.2 0.6 14.1 10.3 12 0.6 13.7 9.5 12.2 0.7 14.1 9.1 165 12 164 165 10.4 0 10.9 9.8 09/08/2006 06:50:00 13.5 0.9 15.6 11.5 13.1 0.8 14.9 11.5 13.4 0.9 15.6 11.1 168 13 169 165 10.4 0 11.1 10.1 09/08/2006 07:00:00 13.1 1 15.3 10.3 12.9 0.8 14.9 10.3 13 1.1 15.6 9.1 169 19 167 165 10.4 0 10.6 10.1 09/08/2006 07:10:00 12.6 1 14.9 9.9 12.4 1 14.5 10.3 12.6 1.1 14.9 9.1 167 17 165 165 10.5 0 10.9 10.1 09/08/2006 07:20:00 12.5 0.5 13.7 10.7 12.3 0.5 13.7 10.7 12.4 0.7 13.7 9.9 166 15 165 165 10.5 0 10.9 10.1 09/08/2006 07:30:00 12.6 0.9 14.1 10.3 12.4 0.8 14.1 9.9 12.5 1 14.5 9.5 166 7 166 165 10.6 0 10.9 10.3 09/08/2006 07:40:00 11.6 0.8 13.7 9.5 11.4 0.7 13.3 9.1 11.4 0.9 14.1 8.8 164 13 164 165 10.6 0.1 10.9 10.3 09/08/2006 07:50:00 10.8 0.7 12.2 8.8 10.6 0.7 11.8 8.8 10.9 0.7 12.6 8.8 164 10 164 165 10.6 0.1 10.9 9.8 09/08/2006 08:00:00 9.9 0.8 11.5 8 9.7 0.8 11.5 7.6 10 0.7 11.8 8.4 164 11 164 165 10.7 0.1 10.9 10.3 09/08/2006 08:10:00 9.7 0.5 11.1 8 9.6 0.5 10.7 8 9.7 0.6 11.1 7.6 165 7 165 165 10.7 0.1 10.9 10.3 09/08/2006 08:20:00 9.7 1 11.8 6.5 9.6 1 11.5 6.1 9.7 1 11.8 6.8 159 7 172 165 10.7 0.1 10.9 10.3 09/08/2006 08:30:00 9.9 1.1 13 7.2 9.7 1.1 12.6 6.8 10.1 1.1 13.3 7.6 162 5 164 165 10.7 0.1 11.1 10.1 09/08/2006 08:40:00 9.6 1.1 13 7.6 9.5 1 12.6 7.2 9.8 1 13.3 7.6 159 8 165 165 10.7 0.1 11.1 10.3 09/08/2006 08:50:00 10.1 0.8 13 8 10 0.8 13 8 10.2 0.8 13 7.6 158 8 161 165 10.7 0 10.9 10.3 09/08/2006 09:00:00 10 0.9 12.6 8 9.8 0.8 12.6 8 10 1 12.2 7.2 159 11 164 165 10.7 0 10.9 10.3 09/08/2006 09:10:00 10.7 1.1 13 8 10.6 1.1 13 8 10.8 1.1 13.7 8 162 9 164 165 10.7 0.1 10.9 10.3 09/08/2006 09:20:00 12.1 0.6 13.7 9.9 12 0.5 13.3 9.9 12.1 0.8 13.7 10.3 166 13 165 165 10.7 0.1 10.9 10.3 09/08/2006 09:30:00 11.5 0.6 13 9.9 11.3 0.6 12.6 9.9 11.5 0.7 13.3 9.5 167 16 169 165 10.7 0 11.1 10.3 09/08/2006 09:40:00 10.6 0.9 12.6 8 10.4 0.9 12.2 8 10.6 0.9 12.6 8 163 13 162 165 10.7 0.1 11.1 10.3 09/08/2006 09:50:00 9 1 11.8 6.1 8.9 1 11.5 6.5 9.2 1 12.2 6.8 158 7 153 165 10.7 0.1 10.9 10.3 09/08/2006 10:00:00 8.8 0.8 11.5 6.8 8.7 0.7 11.1 7.2 9.2 0.7 11.1 7.6 158 6 165 165 10.6 0.2 10.9 10.3 09/08/2006 10:10:00 9.3 0.7 10.7 7.2 9.2 0.7 10.7 6.8 9.5 0.8 11.5 7.6 160 8 165 165 10.6 0.1 10.9 10.3 09/08/2006 10:20:00 9.9 1 11.8 7.2 9.8 0.9 11.5 7.2 10 1 12.2 7.2 162 12 165 165 10.4 0 10.9 9.8 09/08/2006 10:30:00 10 0.6 11.8 8.4 9.8 0.6 11.5 8.4 10.1 0.6 11.8 8.4 166 8 165 165 10.2 0.1 10.6 9.8 09/08/2006 10:40:00 9.2 0.7 11.1 7.2 9 0.6 11.1 7.2 9.2 0.7 11.1 6.8 169 22 174 165 10.3 0 10.6 9.8 09/08/2006 10:50:00 8.9 0.8 10.7 6.5 8.7 0.7 10.3 6.8 9 0.8 10.7 6.8 166 9 165 165 10.3 0 10.6 9.8 09/08/2006 11:00:00 10.1 0.6 11.5 8 9.9 0.6 11.5 8 10.2 0.7 11.8 8.4 167 15 167 165 10.3 0 10.6 9.8 09/08/2006 11:10:00 10.5 0.6 12.2 8 10.2 0.6 11.8 8 10.7 0.6 12.2 8.8 166 15 167 165 10.1 0.1 10.9 9.8 09/08/2006 11:20:00 9.7 0.6 11.1 8 9.5 0.6 10.7 7.6 9.7 0.7 11.5 7.6 164 6 166 165 10.2 0.1 10.6 9.6 09/08/2006 11:30:00 10 0.8 12.6 7.2 9.9 0.8 11.8 7.2 10.1 0.9 12.2 8 163 14 161 165 10.2 0 10.6 9.8 09/08/2006 11:40:00 9.5 1 11.8 6.8 9.4 0.9 11.5 6.8 9.6 1 11.5 7.2 163 11 237 165 10.3 0 10.9 9.8 09/08/2006 11:50:00 9.5 0.9 11.8 7.2 9.4 0.9 11.5 7.6 9.5 1 12.2 7.2 162 8 162 165 10.5 0.1 10.9 10.1 09/08/2006 12:00:00 10.1 0.7 12.2 8 9.9 0.7 11.5 8 10.1 0.8 11.8 7.6 163 13 172 165 10.6 0 10.9 10.3 09/08/2006 12:10:00 10.7 0.9 12.6 7.6 10.6 0.9 12.6 7.2 10.7 1.1 13 6.5 165 6 165 165 10.5 0 10.9 10.1 09/08/2006 12:20:00 11.1 0.7 12.6 9.1 10.9 0.7 13 9.1 11.1 0.8 12.6 8.4 167 12 163 165 10.3 0 10.6 9.8 09/08/2006 12:30:00 11.1 0.7 12.6 8.8 10.9 0.7 12.2 8.4 11 1 13 8.4 163 13 164 165 10.2 0.1 10.6 9.8 09/08/2006 12:40:00 11.3 0.6 12.2 9.5 11 0.6 12.2 9.1 11.4 0.7 12.6 8.8 167 14 164 165 10.1 0 10.6 9.6 09/08/2006 12:50:00 10.6 0.7 12.2 8.8 10.3 0.7 11.8 8.4 10.7 0.8 12.2 8.4 167 12 164 165 10 0 10.3 9.6 09/08/2006 13:00:00 10.2 0.8 11.8 8 10 0.7 11.1 8 10.1 0.9 11.8 8 166 13 172 165 10 0 10.3 9.6 09/08/2006 13:10:00 10.4 0.7 12.2 8.8 10.2 0.7 11.8 8.8 10.5 0.7 12.6 8.8 166 15 164 165 10 0 10.3 9.6 09/08/2006 13:20:00 9.5 0.8 11.5 7.6 9.3 0.8 11.1 7.6 9.6 0.9 11.8 7.2 164 9 176 165 10 0 10.3 9.6 09/08/2006 13:30:00 9.4 0.7 11.1 7.2 9.1 0.7 10.7 6.8 9.5 0.7 11.5 7.6 165 9 164 165 9.9 0 10.3 9.6 09/08/2006 13:40:00 9.3 0.7 11.1 7.6 9.1 0.6 10.7 7.2 9.3 0.8 10.7 7.2 166 12 170 165 9.8 0 10.3 9.3 09/08/2006 13:50:00 9 0.8 10.3 6.8 8.8 0.8 10.3 6.8 9 0.9 10.7 6.5 166 6 167 165 9.8 0 10.1 9.3 09/08/2006 14:00:00 8.8 0.7 10.3 7.2 8.5 0.7 10.3 6.8 8.8 0.8 10.7 6.8 167 5 164 165 9.9 0 10.3 9.6 09/08/2006 14:10:00 8.5 0.6 9.9 6.1 8.2 0.6 9.5 6.1 8.5 0.8 9.9 6.1 166 11 167 165 9.9 0 10.3 9.3 09/08/2006 14:20:00 8.6 0.6 10.3 6.8 8.4 0.6 9.9 6.8 8.6 0.7 10.3 6.1 164 9 166 165 10 0.2 10.3 9.6 09/08/2006 14:30:00 8.7 0.6 9.9 6.8 8.6 0.6 10.3 6.8 8.7 0.6 10.3 6.8 166 12 164 165 10 0.1 10.6 9.6 09/08/2006 14:40:00 9.1 0.7 10.7 7.2 8.9 0.7 10.7 6.8 9.2 0.7 10.7 7.2 164 12 154 165 9.9 0 10.6 9.6 09/08/2006 14:50:00 8.5 0.7 9.9 5.7 8.4 0.7 9.9 5.3 8.5 0.7 9.9 6.1 165 12 160 165 9.8 0 10.3 9.3 09/08/2006 15:00:00 8.5 0.4 9.5 7.2 8.2 0.4 9.1 6.8 8.7 0.4 9.5 7.6 166 12 164 165 9.8 0 10.1 9.3 09/08/2006 15:10:00 9.1 0.5 10.3 7.6 8.8 0.5 9.9 7.2 9.1 0.5 10.3 7.2 167 15 187 165 9.8 0 10.1 9.3 09/08/2006 15:20:00 9.1 0.6 10.7 7.2 8.8 0.6 10.3 6.8 9 0.8 10.7 6.5 165 12 164 165 9.9 0.1 10.3 9.3 09/08/2006 15:30:00 9.1 0.5 10.3 7.6 8.9 0.5 9.9 7.6 9.1 0.6 10.3 6.8 166 6 165 165 10 0.1 10.3 9.6 09/08/2006 15:40:00 8.8 0.6 10.3 6.8 8.5 0.6 9.9 6.8 8.8 0.6 10.3 6.8 165 5 166 165 10 0.1 10.3 9.6 09/08/2006 15:50:00 8.6 0.6 10.3 7.2 8.4 0.6 9.9 7.2 8.7 0.7 10.7 6.8 165 13 163 165 9.9 0.1 10.3 9.6 09/08/2006 16:00:00 8.5 0.8 10.3 5.7 8.3 0.8 9.9 5.7 8.5 0.9 10.7 5.7 164 9 165 165 9.8 0 10.3 9.3 09/08/2006 16:10:00 6.3 0.9 8.8 4.6 6.3 0.8 8.8 4.6 6.4 0.8 9.1 4.6 153 7 156 165 10 0.1 10.3 9.6 09/08/2006 16:20:00 7.4 1 9.1 4.2 7.3 1 8.8 3.8 7.5 1 9.5 4.9 157 10 156 165 9.9 0.2 10.3 9.3 09/08/2006 16:30:00 8.3 0.7 9.9 6.5 8.2 0.7 9.9 6.5 8.3 0.7 9.9 6.5 165 16 162 165 9.7 0 9.8 9 09/08/2006 16:40:00 8.5 0.7 10.3 6.1 8.3 0.6 9.9 6.5 8.6 0.8 10.3 6.1 167 8 165 165 9.8 0 10.1 9.3 09/08/2006 16:50:00 7.7 0.6 9.1 6.1 7.4 0.7 8.8 5.7 8 0.6 9.5 6.5 167 12 172 165 9.8 0 10.3 9.3 09/08/2006 17:00:00 5.7 0.9 8.8 4.2 5.5 0.8 8 4.2 5.9 0.8 8 4.6 167 11 168 165 9.8 0 10.1 9.3 09/08/2006 17:10:00 5.6 0.8 7.6 4.2 5.3 0.8 7.2 3.8 5.7 0.7 7.2 4.2 163 12 173 165 9.8 0 10.1 9.3 09/08/2006 17:20:00 7 0.5 8 5.7 6.6 0.5 7.6 5.3 7 0.6 8.4 4.9 168 15 166 165 9.8 0 10.1 9.3 09/08/2006 17:30:00 7.5 0.8 9.1 5.7 7.2 0.7 8.8 5.7 7.6 0.8 9.1 5.7 166 6 168 165 9.8 0 10.3 9.3 09/08/2006 17:40:00 8.3 0.6 9.5 6.8 7.9 0.6 9.1 6.5 8.3 0.7 9.5 6.5 169 13 168 165 9.7 0.1 9.8 9 09/08/2006 17:50:00 8.2 0.5 9.1 6.5 7.8 0.4 8.8 6.5 8.2 0.5 9.1 6.5 169 4 172 165 9.8 0 9.8 9 09/08/2006 18:00:00 6.9 0.7 8.8 5.3 6.6 0.6 8 5.3 7.1 0.7 9.1 5.7 169 5 166 165 9.7 0 9.8 9 09/08/2006 18:10:00 7.8 0.8 9.5 5.3 7.5 0.8 9.1 5.3 7.9 0.8 9.5 5.7 168 4 164 165 9.7 0.1 9.8 9 09/08/2006 18:20:00 7.4 0.7 8.8 5.7 7.1 0.6 8.4 5.3 7.5 0.7 9.5 5.7 169 16 165 165 9.6 0.2 9.8 9 09/08/2006 18:30:00 6.9 0.4 7.6 4.9 6.7 0.4 7.6 4.9 7.2 0.5 8.4 5.7 167 6 171 165 9.6 0.1 10.1 9 09/08/2006 18:40:00 6.7 0.5 7.6 5.3 6.5 0.5 7.2 5.3 7 0.6 8 5.3 169 4 172 165 9.6 0.2 9.8 9 09/08/2006 18:50:00 5.6 0.5 6.5 4.2 5.4 0.5 6.5 4.2 6 0.5 6.8 4.9 167 3 165 165 9.6 0.2 10.1 9 09/08/2006 19:00:00 4.6 0.3 5.7 3.8 4.5 0.3 5.3 3.8 4.9 0.3 5.7 4.2 174 5 180 165 9.6 0.2 9.8 9 09/08/2006 19:10:00 4.8 0.6 6.1 3.8 4.5 0.5 5.7 3.4 4.9 0.5 6.1 3.8 171 5 165 165 9.6 0.2 9.8 9 09/08/2006 19:20:00 5.1 0.4 6.1 4.2 4.8 0.3 5.7 3.8 5 0.4 5.7 3.8 170 3 174 165 9.6 0.2 9.8 9 09/08/2006 19:30:00 4.7 0.4 5.7 3.4 4.4 0.4 5.3 3 4.8 0.4 5.7 3.4 171 11 173 165 9.6 0.1 9.8 9 09/08/2006 19:40:00 4.8 0.6 6.1 3.4 4.5 0.6 6.5 3.4 5 0.6 6.5 3.8 172 6 178 165 9.6 0.1 9.6 9 09/08/2006 19:50:00 5.4 0.9 7.6 3.8 5.2 0.9 7.2 3.4 5.6 0.8 7.6 3.8 174 12 166 165 9.6 0.1 9.6 9 09/08/2006 20:00:00 5.9 0.5 6.8 4.2 5.7 0.4 6.8 4.2 6.1 0.5 7.2 4.6 171 6 166 165 9.5 0 9.6 9 09/08/2006 20:10:00 5.4 0.6 6.8 3.8 5.2 0.6 6.5 3.8 5.7 0.6 6.8 4.2 172 9 171 165 9.4 0 9.6 9 09/08/2006 20:20:00 5.8 0.7 7.2 4.2 5.5 0.6 6.5 3.8 5.9 0.6 7.2 4.6 175 5 174 165 9.3 0 9.6 9 09/08/2006 20:30:00 6 0.5 7.2 4.6 5.8 0.5 6.8 4.6 6.2 0.5 7.2 4.9 174 5 177 165 9.2 0 9.3 9 09/08/2006 20:40:00 6.8 0.5 7.6 5.3 6.5 0.4 7.2 4.9 7.1 0.5 8 5.3 168 3 166 165 9.2 0 9.3 9 09/08/2006 20:50:00 5.8 0.5 6.8 4.9 5.5 0.5 6.5 4.2 6 0.5 7.2 4.9 172 4 171 165 9.2 0 9.3 9 09/08/2006 21:00:00 6.1 0.7 8.4 4.6 5.8 0.6 7.6 4.6 6.2 0.7 8.8 4.9 169 10 170 165 9 0 9.3 9 09/08/2006 21:10:00 6 0.7 7.6 4.6 5.9 0.6 7.6 4.6 6.3 0.6 8.4 4.9 173 8 171 165 9 0 9 9 09/08/2006 21:20:00 6.4 0.6 7.6 4.9 6.2 0.5 7.2 4.9 6.7 0.5 8.4 5.3 171 6 174 165 9 0 9 8.8 09/08/2006 21:30:00 6.4 0.5 8 4.9 6.3 0.5 7.6 4.9 6.8 0.5 8 5.3 171 12 177 165 9 0 9 8.8 09/08/2006 21:40:00 6.7 0.4 7.6 5.3 6.5 0.4 7.6 5.3 7 0.5 8.4 5.7 169 11 176 165 8.9 0 9 8.8 09/08/2006 21:50:00 6.5 0.6 8 4.9 6.3 0.5 7.6 4.9 6.7 0.5 8 5.3 173 4 170 165 8.9 0 9 8.8 09/08/2006 22:00:00 6.5 0.6 8 5.3 6.4 0.5 7.2 4.9 6.7 0.5 8 5.3 173 5 178 165 8.7 0 9 8.5 09/08/2006 22:10:00 6.5 0.5 8 4.9 6.3 0.5 7.6 4.9 6.8 0.5 8 4.9 168 8 167 165 8.7 0 9 8.5 09/08/2006 22:20:00 7 0.6 8 5.7 6.8 0.5 7.6 5.3 7.3 0.5 8.8 5.7 169 9 166 165 8.7 0 9 8.5 09/08/2006 22:30:00 6.5 0.9 8.4 4.9 6.3 0.8 8.4 4.9 6.8 0.8 8.8 4.9 172 6 170 165 8.7 0 8.8 8.5 09/08/2006 22:40:00 5.5 0.5 6.8 4.2 5.4 0.5 6.8 4.2 5.9 0.5 7.6 4.6 171 7 173 165 8.7 0 9 8.5 09/08/2006 22:50:00 5.3 0.5 6.8 4.2 5.3 0.5 6.8 4.2 5.7 0.5 6.8 4.6 165 6 163 165 8.7 0 8.8 8.5 09/08/2006 23:00:00 7.1 1.1 9.1 4.9 7 1 8.8 4.9 7.3 1 9.5 4.6 167 12 168 165 8.6 0 8.8 8.5 09/08/2006 23:10:00 8.9 0.7 10.7 6.8 8.6 0.7 9.9 6.5 9 0.8 10.7 6.5 168 4 165 165 8.6 0 8.8 8.3 09/08/2006 23:20:00 9.3 0.6 10.3 7.6 9.1 0.5 10.3 7.6 9.5 0.7 11.1 7.6 167 13 166 165 8.6 0.1 8.8 8.3 09/08/2006 23:30:00 9.1 0.5 10.7 7.6 8.9 0.5 9.9 7.6 9.1 0.6 10.3 7.2 166 17 165 165 8.5 0 8.8 8.3 09/08/2006 23:40:00 8.7 0.4 9.5 7.2 8.4 0.4 9.1 6.8 8.9 0.5 9.9 7.2 168 15 171 165 8.5 0 8.8 8.3 09/08/2006 23:50:00 8.7 0.7 9.9 6.8 8.4 0.6 9.9 6.8 8.7 0.8 10.3 6.5 168 10 165 165 8.5 0.1 8.8 8 09/09/2006 00:00:00 10 0.6 11.1 7.6 9.8 0.6 11.1 7.6 10.3 0.6 11.8 8 167 10 169 165 8.5 0 8.8 8.3 09/09/2006 00:10:00 9.2 0.7 10.7 7.6 8.9 0.6 10.3 7.2 9.3 0.7 11.1 7.2 166 17 169 165 8.5 0.1 8.8 8.3 09/09/2006 00:20:00 8.9 0.6 10.3 6.8 8.5 0.6 9.9 6.8 9.1 0.8 10.7 6.1 167 10 163 165 8.5 0 8.5 8 09/09/2006 00:30:00 7.4 0.6 8.8 5.7 7.1 0.5 8.4 5.7 7.6 0.6 8.8 6.1 165 11 166 165 8.3 0 8.5 7.8 09/09/2006 00:40:00 7.3 0.6 8.8 5.7 7.1 0.6 8.4 5.3 7.5 0.6 9.1 6.1 163 6 164 165 8.4 0 8.5 7.8 09/09/2006 00:50:00 7.4 0.6 8.8 5.7 7.3 0.6 8.4 5.7 7.6 0.6 8.8 6.1 162 12 163 165 8.4 0 8.5 7.8 09/09/2006 01:00:00 7.5 0.5 8.8 6.1 7.2 0.5 8.4 5.7 7.7 0.6 9.1 6.1 162 5 143 165 8.3 0 8.8 7.8 09/09/2006 01:10:00 7.2 0.5 8.4 6.1 7 0.4 8 6.1 7.5 0.4 8.4 6.5 161 4 165 165 8.2 0 8.5 7.5 09/09/2006 01:20:00 6.8 0.6 8 5.3 6.6 0.5 7.6 5.3 7 0.5 8 5.7 163 5 162 165 8.3 0 8.5 7.5 09/09/2006 01:30:00 6.5 0.4 8 5.3 6.3 0.4 7.6 5.3 6.7 0.5 8 5.3 159 6 156 165 8.3 0 8.5 7.8 09/09/2006 01:40:00 6.9 0.5 8 5.7 6.7 0.5 8 5.3 7.1 0.5 8.4 6.1 160 4 164 165 8.3 0 8.5 8.3 09/09/2006 01:50:00 7.1 0.5 8.4 5.3 6.9 0.4 8 5.3 7.2 0.5 8.4 5.7 164 5 162 165 8.3 0 8.5 8.3 09/09/2006 02:00:00 6.1 0.5 7.2 4.9 5.9 0.5 7.2 4.9 6.3 0.6 7.6 4.9 164 12 164 165 8.1 0 8.5 8 09/09/2006 02:10:00 5.4 0.2 6.1 4.6 5.2 0.2 5.7 4.6 5.8 0.3 6.5 4.9 164 2 165 165 8.3 0 8.5 8 09/09/2006 02:20:00 5 0.3 5.7 3.8 4.8 0.3 5.3 3.8 5.3 0.3 6.1 4.6 162 2 162 165 8.3 0 8.5 8.3 09/09/2006 02:30:00 4.8 0.3 5.3 3.8 4.6 0.3 5.3 3.8 5 0.3 5.7 4.2 162 2 160 165 8.3 0 8.5 8.3 09/09/2006 02:40:00 5 0.4 6.1 4.2 4.8 0.4 5.7 3.8 5.2 0.4 6.1 4.2 163 2 161 165 8.3 0 8.5 8.3 09/09/2006 02:50:00 4.8 0.3 5.7 3.8 4.6 0.3 5.3 3.8 5 0.3 5.7 4.2 163 2 164 165 8.1 0 8.3 8 09/09/2006 03:00:00 5 0.3 5.7 4.2 4.9 0.3 5.7 4.2 5.2 0.4 6.1 4.2 164 9 162 165 8 0 8.5 8 09/09/2006 03:10:00 5.3 0.4 6.5 4.2 5.1 0.4 6.5 4.2 5.3 0.4 6.5 3.8 162 2 164 165 8 0 8.3 7.8 09/09/2006 03:20:00 5.6 0.3 6.5 4.9 5.4 0.3 6.1 4.9 5.7 0.3 6.5 4.6 165 15 165 165 7.9 0 8 7.8 09/09/2006 03:30:00 5.6 0.6 7.2 4.6 5.3 0.6 6.8 4.2 5.7 0.6 7.2 4.2 165 3 166 165 8 0 8.3 7.8 09/09/2006 03:40:00 5.6 0.6 6.8 3.8 5.4 0.5 6.5 3.4 5.8 0.6 6.8 3.8 164 5 164 165 8 0 8.3 7.8 09/09/2006 03:50:00 5.2 0.4 6.1 3.8 5 0.4 5.7 3.8 5.4 0.5 6.1 3.8 164 4 165 165 8.1 0 8.3 7.5 09/09/2006 04:00:00 4.5 0.5 5.3 3.4 4.3 0.4 5.3 3.4 4.8 0.5 5.7 3.4 160 3 164 165 8 0 8.3 7.5 09/09/2006 04:10:00 4.7 0.6 6.8 3.4 4.6 0.6 6.5 3.4 5 0.6 7.2 3.8 162 4 164 165 8 0.1 8.3 7.5 09/09/2006 04:20:00 4.8 0.6 6.1 3.4 4.7 0.5 5.7 3.4 5 0.6 6.1 3.8 162 6 163 165 8 0.1 8.3 7.5 09/09/2006 04:30:00 5.3 0.4 6.5 4.6 5.1 0.3 6.1 4.6 5.5 0.4 6.5 4.2 163 2 163 165 8 0.1 8 7.3 09/09/2006 04:40:00 4.4 0.3 4.9 3.8 4.3 0.3 4.9 3.4 4.6 0.3 5.3 3.8 162 4 161 165 8 0.1 8 7.3 09/09/2006 04:50:00 3.9 0.6 4.9 2.6 3.8 0.5 4.6 2.6 4.1 0.5 4.9 3 162 2 164 165 7.9 0.1 8 7.5 09/09/2006 05:00:00 2.7 0.3 3.4 1.9 2.7 0.3 3.4 1.9 3.1 0.3 3.8 2.3 157 4 164 165 7.9 0.1 8.5 7.5 09/09/2006 05:10:00 2.4 0.4 3 1.5 2.4 0.4 3 1.5 2.7 0.3 3.4 1.9 149 3 157 165 7.9 0 8 7.5 09/09/2006 05:20:00 1.9 0.2 2.6 1.5 1.8 0.3 2.3 1.1 2.3 0.2 3 1.5 143 2 145 165 7.9 0 8 7.5 09/09/2006 05:30:00 3.2 0.5 4.2 1.9 3.2 0.5 4.6 1.9 3.4 0.5 4.6 2.3 139 5 137 165 8 0 8.3 7.5 09/09/2006 05:40:00 3.8 0.5 4.9 2.6 3.7 0.4 4.6 2.6 3.8 0.4 4.9 2.3 138 9 130 165 8.3 0 8.5 7.8 09/09/2006 05:50:00 3.6 0.8 5.3 1.5 3.6 0.8 5.3 1.5 3.7 0.8 5.7 1.9 146 13 139 165 8.3 0 8.5 7.8 09/09/2006 06:00:00 4.5 0.5 6.1 3 4.5 0.5 5.7 3 4.6 0.5 5.7 3 140 9 144 165 8.4 0 8.5 7.8 09/09/2006 06:10:00 5 0.7 6.5 3.4 5.1 0.7 6.5 3.4 5.1 0.6 6.5 3.4 138 6 136 165 8.5 0 8.5 8.3 09/09/2006 06:20:00 4.8 0.5 5.7 3.4 4.9 0.5 6.1 3.4 4.8 0.6 6.1 3 138 6 139 165 8.5 0 8.8 8.5 09/09/2006 06:30:00 4.6 0.5 5.7 3.4 4.6 0.5 5.7 3.4 4.6 0.5 5.7 3.4 140 7 140 165 8.5 0 8.8 8.5 09/09/2006 06:40:00 4.2 0.6 5.3 2.6 4.3 0.6 5.3 2.6 4.4 0.5 5.7 3 138 8 135 165 8.5 0 8.5 8.5 09/09/2006 06:50:00 4.4 0.4 5.3 3.4 4.5 0.4 5.7 3.4 4.6 0.4 5.3 3.4 133 7 140 165 8.5 0 8.5 8.5 09/09/2006 07:00:00 4.1 0.4 4.9 3 4.1 0.4 4.9 2.6 4.3 0.4 5.3 3.4 135 6 145 165 8.5 0 9 8.3 09/09/2006 07:10:00 4.2 0.4 4.9 3 4.2 0.4 4.9 3.4 4.3 0.3 5.3 3.4 134 6 135 165 8.3 0 8.5 8.3 09/09/2006 07:20:00 4 0.4 4.9 3 4.1 0.4 4.9 3 4.2 0.4 4.9 3.4 132 6 121 165 8.3 0 8.5 8 09/09/2006 07:30:00 4.1 0.4 4.9 3 4.1 0.4 4.9 3 4.2 0.4 5.3 3.4 127 5 125 165 8.3 0 8.5 8.3 09/09/2006 07:40:00 3.9 0.4 4.9 3 3.9 0.4 4.9 2.6 4.1 0.4 4.9 3 133 5 126 165 8.1 0 8.3 8 09/09/2006 07:50:00 3.8 0.3 4.6 3 3.8 0.3 4.6 3 3.9 0.3 4.6 3 134 5 140 165 8 0 8.3 7.8 09/09/2006 08:00:00 4.1 0.4 4.9 3 4.2 0.4 5.3 3.4 4.2 0.4 5.7 3 123 3 119 165 8.1 0 8.3 7.8 09/09/2006 08:10:00 4.7 0.4 6.1 3.8 4.8 0.4 6.1 3.4 4.8 0.4 6.1 3.8 124 5 118 165 8.3 0 8.5 8 09/09/2006 08:20:00 4.9 0.4 5.7 3.4 5 0.4 5.7 3.8 4.9 0.4 5.7 3.4 118 5 112 165 8.1 0 8.5 7.8 09/09/2006 08:30:00 6.5 0.6 7.6 3.8 6.6 0.6 7.6 3.8 6.4 0.6 7.6 3.8 119 6 117 165 8.5 0.1 8.8 8.3 09/09/2006 08:40:00 5.9 0.4 7.2 4.9 5.9 0.4 7.2 4.9 5.9 0.4 7.2 4.9 123 5 135 165 8.5 0.1 8.8 8 09/09/2006 08:50:00 5.4 0.3 6.5 4.6 5.5 0.4 6.5 4.6 5.4 0.4 6.1 4.2 119 5 121 165 8.5 0.1 8.8 8 09/09/2006 09:00:00 5.2 0.7 6.8 3 5.3 0.6 7.2 3.4 5.1 0.7 6.8 3.8 120 6 116 165 8.5 0.1 8.8 8 09/09/2006 09:10:00 5.5 0.6 7.2 3.8 5.5 0.5 6.5 3.8 5.3 0.6 6.5 3.8 123 8 120 165 8.5 0.1 8.5 8 09/09/2006 09:20:00 5.5 0.6 7.2 3.8 5.6 0.6 7.2 3.8 5.3 0.6 6.8 3.8 119 5 121 165 8.5 0.1 8.5 8 09/09/2006 09:30:00 5.3 0.6 6.5 3.4 5.4 0.6 6.5 3.8 5.1 0.6 6.5 3 114 6 112 165 8.5 0.1 8.8 8 09/09/2006 09:40:00 5.5 0.6 7.2 3.8 5.6 0.6 7.2 3.4 5.4 0.6 6.8 3.4 119 10 118 165 8.5 0.1 8.8 8 09/09/2006 09:50:00 4.7 1.2 6.8 2.3 4.8 1.3 7.2 2.3 4.7 1.1 7.6 2.6 117 10 111 165 8.5 0 8.8 8.3 09/09/2006 10:00:00 4.1 0.8 6.1 2.3 4.2 0.8 6.5 2.6 4.3 0.8 6.1 2.3 121 7 106 165 8.7 0 9 8.5 09/09/2006 10:10:00 5.2 1.4 8 1.9 5.3 1.5 8.4 1.9 5 1.4 8 2.3 112 10 112 165 9.1 0.2 9.6 8.8 09/09/2006 10:20:00 6.2 0.8 8.8 3.8 6.4 0.9 9.5 3.8 6.2 0.8 9.1 4.2 118 8 119 165 9.8 0.2 10.3 9.3 09/09/2006 10:30:00 6 0.8 8 3.8 6.1 0.8 8 4.2 6 0.8 8.4 3.4 126 9 115 165 10 0.2 10.6 9.3 09/09/2006 10:40:00 7.1 0.6 8.4 5.7 7.1 0.6 8.8 5.3 7.1 0.6 8.8 5.7 132 5 126 165 10.4 0.1 10.9 9.8 09/09/2006 10:50:00 6.8 0.8 8.8 4.9 6.9 0.8 9.1 4.9 7 0.8 9.1 4.9 134 7 129 165 10.5 0.2 11.1 9.8 09/09/2006 11:00:00 6.9 0.8 9.1 4.9 6.9 0.8 9.1 4.2 6.9 0.8 9.1 4.6 131 7 128 165 10 0 10.3 9.6 09/09/2006 11:10:00 6.9 0.6 8.4 5.3 6.9 0.6 8.8 5.3 7 0.6 8.8 5.3 132 6 131 165 10.3 0.1 10.9 9.6 09/09/2006 11:20:00 7.1 0.5 8.8 6.1 7.1 0.5 9.1 6.1 7.2 0.5 8.8 6.1 135 6 132 165 10.7 0.3 11.4 10.3 09/09/2006 11:30:00 6.5 0.7 8.4 4.6 6.5 0.7 8.4 4.6 6.7 0.7 8.8 4.9 141 7 137 165 11.2 0 11.4 10.9 09/09/2006 11:40:00 6.9 0.6 8.8 4.9 6.8 0.7 8.8 4.9 7 0.6 8.8 5.3 139 8 141 165 11.5 0 11.9 11.1 09/09/2006 11:50:00 7.2 0.6 8.8 5.3 7.1 0.7 8.8 5.3 7.2 0.7 8.8 5.3 138 6 144 165 11 0.3 11.7 10.6 09/09/2006 12:00:00 7 0.6 8.4 5.3 7 0.6 8.8 5.3 7.1 0.6 9.1 5.3 138 6 137 165 10.8 0.1 11.1 10.6 09/09/2006 12:10:00 7.2 0.5 8.4 6.1 7.2 0.5 8.4 5.7 7.3 0.5 8.4 5.7 138 5 132 165 10.6 0.1 11.1 10.3 09/09/2006 12:20:00 7 0.6 8.4 5.3 7 0.6 8.8 4.9 7.1 0.7 9.1 4.9 136 7 129 165 10.6 0.1 10.9 10.3 09/09/2006 12:30:00 6.5 0.6 8.4 4.6 6.5 0.6 8.4 4.6 6.6 0.6 8.4 4.6 132 7 131 165 10.7 0.1 11.1 10.3 09/09/2006 12:40:00 6.5 0.6 8.4 5.3 6.5 0.6 8.8 4.9 6.6 0.6 8.4 5.3 135 7 126 165 10.7 0.1 10.9 10.3 09/09/2006 12:50:00 6.9 0.6 8.4 4.9 6.9 0.6 8.4 4.9 7 0.7 8.8 4.9 138 7 137 165 10.8 0.2 11.1 10.1 09/09/2006 13:00:00 7 0.6 8.4 5.3 7 0.7 8.8 5.3 7.3 0.7 9.1 5.3 140 8 141 165 11.3 0.1 11.7 11.1 09/09/2006 13:10:00 7.5 0.6 9.1 5.7 7.5 0.6 9.1 5.7 7.6 0.7 9.5 5.3 141 5 147 165 11.3 0 11.9 11.1 09/09/2006 13:20:00 7.3 0.6 8.8 5.7 7.2 0.6 8.8 5.3 7.3 0.6 9.1 5.3 138 7 145 165 11.1 0 11.4 10.9 09/09/2006 13:30:00 6.8 0.6 9.1 4.9 6.8 0.6 9.1 5.3 6.8 0.6 9.1 5.3 136 8 123 165 11.7 0.3 12.2 11.1 09/09/2006 13:40:00 7.5 0.5 8.8 5.7 7.5 0.5 8.8 6.1 7.5 0.6 8.8 4.9 130 5 124 165 10.9 0.2 11.4 10.6 09/09/2006 13:50:00 7.2 0.6 9.5 4.9 7.2 0.7 9.1 4.9 7.3 0.7 9.5 4.9 135 7 131 165 11.7 0.4 12.5 11.1 09/09/2006 14:00:00 7.2 0.6 9.1 5.3 7.2 0.6 9.1 5.3 7.3 0.6 8.8 5.7 138 7 132 165 11.7 0.4 12.7 11.1 09/09/2006 14:10:00 7.4 0.5 9.1 5.7 7.4 0.5 8.8 5.7 7.6 0.6 8.8 5.7 141 6 144 165 11.2 0.4 11.9 10.9 09/09/2006 14:20:00 7.7 0.7 9.1 5.7 7.8 0.7 9.5 6.1 7.9 0.7 9.5 5.7 132 7 123 165 11.3 0.2 11.9 11.1 09/09/2006 14:30:00 8.1 0.5 9.1 6.5 8.2 0.5 9.5 6.8 8.1 0.6 9.5 6.5 129 5 121 165 10.9 0.4 12.2 10.3 09/09/2006 14:40:00 8.6 0.5 9.9 7.2 8.7 0.5 9.9 7.2 8.7 0.5 10.3 7.2 135 6 128 165 10.1 0.1 10.6 9.6 09/09/2006 14:50:00 7.7 0.8 9.1 5.3 7.7 0.7 9.5 5.7 7.7 0.8 9.5 4.9 138 6 137 165 9.6 0.1 9.8 9.3 09/09/2006 15:00:00 6.7 0.5 8 5.3 6.8 0.5 8.4 5.3 6.8 0.6 8 4.2 133 6 130 165 9.7 0.1 9.8 9.3 09/09/2006 15:10:00 6.4 0.8 9.1 4.6 6.5 0.8 9.1 4.9 6.4 0.7 9.1 4.9 132 7 132 165 9.8 0 9.8 9.3 09/09/2006 15:20:00 7.3 0.6 9.1 5.3 7.4 0.6 8.8 5.3 7.3 0.7 9.5 5.7 129 7 136 165 9.6 0.1 9.8 9 09/09/2006 15:30:00 7.1 0.7 9.1 4.9 7.2 0.7 9.5 4.6 7.1 0.8 9.9 4.9 130 6 124 165 9.6 0 9.8 9.6 09/09/2006 15:40:00 6.9 0.7 8.8 4.6 7 0.7 9.1 4.9 6.9 0.7 8.4 4.9 123 6 120 165 9.6 0.1 9.8 9.3 09/09/2006 15:50:00 6.6 0.9 8.4 4.2 6.7 0.9 8.8 4.2 6.6 0.9 8.4 4.2 123 6 118 165 9.6 0.1 9.8 9.3 09/09/2006 16:00:00 6.7 0.8 8.4 4.6 6.8 0.8 8.8 4.6 6.6 0.7 8.4 4.6 121 5 121 165 9.7 0.1 9.8 9.3 09/09/2006 16:10:00 6.2 0.7 8 3.8 6.3 0.8 8 3.8 6.2 0.7 8 3.8 118 5 113 165 9.8 0 9.8 9.3 09/09/2006 16:20:00 6.9 0.7 9.1 4.2 7 0.7 9.5 4.6 6.7 0.7 8.8 4.6 112 6 113 165 9.8 0 9.8 9.3 09/09/2006 16:30:00 6.8 0.6 8 4.9 6.9 0.6 8.8 5.3 6.3 0.7 8 4.6 115 5 116 165 9.8 0 9.8 9.3 09/09/2006 16:40:00 6.9 0.8 8.8 4.2 7 0.8 8.8 4.6 6.6 0.8 8.8 4.6 113 5 111 165 9.7 0.1 10.3 9 09/09/2006 16:50:00 6.9 0.7 8.8 4.9 7.1 0.7 8.8 4.9 6.7 0.8 8.8 4.6 116 5 110 165 9.6 0.1 9.8 9 09/09/2006 17:00:00 7.4 0.6 9.1 6.1 7.6 0.6 8.8 6.1 7.1 0.7 8.8 4.9 118 5 123 165 9.6 0 9.8 9.3 09/09/2006 17:10:00 7.2 0.5 8.4 4.6 7.3 0.5 8.4 4.9 6.9 0.6 9.1 4.9 114 5 112 165 9.6 0.1 9.8 9.3 09/09/2006 17:20:00 7.7 0.5 9.1 5.3 7.8 0.6 9.1 5.3 7.4 0.7 8.8 5.3 113 5 102 165 9.6 0.1 9.8 9.3 09/09/2006 17:30:00 7.6 0.8 9.5 5.3 7.7 0.8 9.9 5.3 7.3 0.8 9.5 4.9 111 6 115 165 9.7 0 9.8 9.3 09/09/2006 17:40:00 7.2 0.6 8.4 4.9 7.4 0.7 8.8 4.6 6.8 0.8 8.8 4.2 113 5 114 165 9.6 0.1 9.8 9.3 09/09/2006 17:50:00 8.1 0.5 9.5 6.5 8.3 0.6 9.9 6.5 8 0.6 9.5 6.5 116 4 122 165 9.7 0.1 10.1 9.3 09/09/2006 18:00:00 8.1 0.6 9.5 6.5 8.3 0.6 9.9 6.8 7.7 0.7 9.9 5.7 118 5 106 165 9.8 0.1 9.8 9.3 09/09/2006 18:10:00 7.2 0.8 9.1 4.9 7.3 0.9 9.1 4.9 6.8 1 9.5 4.2 116 5 111 165 9.6 0.2 9.8 9 09/09/2006 18:20:00 7.1 0.7 8.8 4.9 7.2 0.8 9.1 4.9 6.8 0.9 8.4 4.2 115 5 122 165 9.6 0.2 9.8 9 09/09/2006 18:30:00 7.3 0.6 8.8 5.7 7.5 0.6 9.1 5.3 7 0.7 8.8 4.9 117 4 128 165 9.5 0.2 9.6 9 09/09/2006 18:40:00 7 0.5 8.4 4.2 7.1 0.5 8.8 4.6 6.7 0.6 8.4 4.6 116 5 117 165 9.6 0.1 9.8 9 09/09/2006 18:50:00 7.3 0.5 8.8 5.3 7.5 0.5 8.8 5.3 7.1 0.6 8.4 4.9 115 3 115 165 9.6 0.1 9.8 9 09/09/2006 19:00:00 7.1 0.7 9.1 4.6 7.3 0.7 9.5 4.6 6.7 0.8 8.8 4.2 114 4 108 165 9.6 0 9.8 9.6 09/09/2006 19:10:00 6.1 0.7 7.6 4.2 6.2 0.7 8 4.2 5.9 0.7 8 3.8 116 6 116 165 9.6 0.1 9.6 9.3 09/09/2006 19:20:00 7.2 0.5 8.4 5.7 7.3 0.5 8.8 6.1 6.9 0.6 8.4 4.9 113 6 107 165 9.5 0 9.6 9.3 09/09/2006 19:30:00 8.3 0.6 9.5 6.8 8.4 0.6 9.5 7.2 7.8 0.7 9.5 6.1 108 5 105 165 9.6 0.1 9.8 9.3 09/09/2006 19:40:00 8.5 0.4 9.5 7.2 8.7 0.5 9.9 7.2 8.2 0.6 9.9 6.1 108 3 111 165 9.6 0.1 10.1 9.3 09/09/2006 19:50:00 7.6 0.5 8.8 5.7 7.8 0.5 9.1 5.7 7.1 0.7 8.4 4.9 105 4 102 165 9.5 0 10.1 9 09/09/2006 20:00:00 7.4 0.6 8.8 5.3 7.5 0.7 9.1 5.3 6.8 0.8 8.4 4.2 101 5 105 165 9.5 0 9.8 9 09/09/2006 20:10:00 8 0.7 9.5 5.7 8.2 0.7 9.9 5.3 7.5 0.8 9.1 4.6 103 4 102 165 9.4 0 9.8 9 09/09/2006 20:20:00 8.1 0.4 8.8 6.8 8.2 0.4 9.1 6.8 7.7 0.6 9.1 5.7 105 3 106 165 9.4 0 9.6 9 09/09/2006 20:30:00 7.8 0.4 8.8 6.5 8 0.4 9.1 6.5 7.4 0.6 8.8 4.9 105 4 106 165 9.4 0 9.6 9 09/09/2006 20:40:00 8 0.4 9.1 6.8 8.2 0.5 9.5 6.8 7.6 0.6 8.8 4.9 105 4 105 165 9.4 0 9.8 9 09/09/2006 20:50:00 7.9 0.5 9.5 6.1 8 0.5 9.5 6.1 7.4 0.7 9.1 5.3 104 3 102 165 9.4 0 9.6 9 09/09/2006 21:00:00 7.5 0.5 8.8 5.7 7.7 0.5 8.8 5.7 7.1 0.7 8.4 5.3 101 4 105 165 9.4 0 9.6 9 09/09/2006 21:10:00 7.1 0.5 8.4 4.9 7.2 0.6 8.4 4.9 6.6 0.7 8 4.2 98 4 97 165 9.4 0 9.8 9 09/09/2006 21:20:00 6.9 0.7 8 4.2 7 0.8 8.4 4.2 6.5 0.8 8 3.4 98 5 98 165 9.4 0 9.6 9 09/09/2006 21:30:00 7.2 0.6 8.4 4.9 7.4 0.6 8.8 5.3 6.8 0.7 8.4 4.9 100 4 94 165 9.4 0 9.6 9 09/09/2006 21:40:00 7.2 0.6 8.4 4.2 7.4 0.6 8.8 4.2 6.7 0.8 8.4 4.6 99 5 103 165 9.4 0 9.6 9 09/09/2006 21:50:00 7.4 0.5 8.8 5.7 7.6 0.5 9.1 5.7 7.1 0.6 8.4 4.9 99 4 99 165 9.4 0 9.6 8.8 09/09/2006 22:00:00 7.3 0.6 8.8 5.3 7.5 0.7 8.8 5.3 6.9 0.7 8.4 4.9 97 5 96 165 9.3 0 9.6 8.8 09/09/2006 22:10:00 7.8 0.6 9.5 5.7 8 0.6 9.9 6.1 7.5 0.7 9.5 5.3 98 4 95 165 9.3 0.1 9.6 8.8 09/09/2006 22:20:00 7.9 0.7 9.1 5.3 8 0.8 9.5 5.3 7.4 0.8 9.1 4.6 99 5 98 165 9.4 0.1 9.6 9 09/09/2006 22:30:00 8.4 0.6 9.5 6.1 8.5 0.6 9.9 6.1 8 0.7 9.5 6.1 101 4 99 165 9.4 0.1 9.6 9 09/09/2006 22:40:00 8.3 0.5 9.5 6.1 8.5 0.5 9.9 6.1 7.8 0.7 9.5 4.9 99 4 98 165 9.4 0.1 9.8 9 09/09/2006 22:50:00 8.3 0.5 9.1 6.8 8.5 0.5 9.5 6.5 7.8 0.8 9.1 5.7 98 3 99 165 9.4 0.1 9.6 9 09/09/2006 23:00:00 8 0.5 8.8 5.7 8.2 0.5 8.8 6.1 7.5 0.7 8.8 4.9 93 3 94 165 9.3 0.1 9.6 9 09/09/2006 23:10:00 7.5 0.6 8.8 5.3 7.7 0.6 8.8 5.3 7 0.7 8.4 4.9 95 4 96 165 9.3 0.1 9.6 9 09/09/2006 23:20:00 7.1 0.6 8.4 4.6 7.3 0.7 8.8 4.6 6.7 0.7 8.4 4.9 96 5 94 165 9.3 0 9.6 9 09/09/2006 23:30:00 7.3 0.5 8 5.7 7.5 0.5 8.4 5.7 6.9 0.6 8.4 5.3 92 4 94 165 9.3 0 9.6 9 09/09/2006 23:40:00 7.3 0.4 8 5.3 7.5 0.4 8.4 5.3 7 0.6 8 5.3 89 3 92 165 9.4 0.1 9.6 9 09/09/2006 23:50:00 6.8 0.6 8 4.9 7 0.6 8.4 4.9 6.5 0.6 8 4.9 81 4 84 165 9.4 0.1 9.6 9 09/10/2006 00:00:00 7.1 0.6 8 5.7 7.2 0.6 8.4 5.7 6.8 0.6 8.4 4.6 83 4 84 165 9.5 0.2 9.8 9 09/10/2006 00:10:00 7.1 1 8.8 4.9 7.3 1 9.1 4.9 6.9 1 8.8 4.2 85 5 89 165 9.5 0.2 10.1 9 09/10/2006 00:20:00 8.6 0.7 9.9 6.5 8.9 0.7 10.3 6.8 8.2 0.8 10.3 6.1 93 4 92 165 9.5 0.2 9.6 8.8 09/10/2006 00:30:00 8.7 0.6 9.9 6.1 8.9 0.6 9.9 6.5 8.3 0.7 9.9 6.5 92 4 94 165 9.4 0 9.6 8.8 09/10/2006 00:40:00 7.6 0.7 9.9 5.7 7.8 0.7 10.3 6.1 7.4 0.7 9.5 5.7 84 5 87 165 9.4 0 9.6 8.8 09/10/2006 00:50:00 8 0.8 9.9 6.1 8.2 0.8 9.9 6.1 7.6 0.9 9.5 4.9 85 5 87 165 9.4 0 9.6 8.8 09/10/2006 01:00:00 7.7 0.8 9.5 5.3 7.9 0.8 9.9 5.3 7.4 0.8 9.1 5.3 83 5 87 165 9.4 0 9.6 9 09/10/2006 01:10:00 7.9 0.8 9.5 5.3 8 0.9 9.9 5.7 7.5 0.8 9.9 5.3 84 6 81 165 9.4 0 9.6 8.8 09/10/2006 01:20:00 8.6 0.7 10.3 6.1 8.9 0.7 10.3 6.5 8.2 0.8 9.9 5.7 88 4 90 165 9.4 0 9.6 8.8 09/10/2006 01:30:00 7.5 0.7 8.8 5.7 7.8 0.7 9.1 5.7 7.4 0.7 8.8 5.3 80 5 87 165 9.3 0 9.6 9 09/10/2006 01:40:00 6.5 0.7 8.4 4.6 6.7 0.7 8.4 4.6 6.2 0.7 8 4.6 72 7 79 165 9.3 0 9.3 9 09/10/2006 01:50:00 5.2 0.7 7.6 3.8 5.4 0.7 7.6 3.4 5.3 0.8 7.6 3.8 69 9 77 165 9.3 0 9.3 9 09/10/2006 02:00:00 5.8 1 8.4 3.8 5.9 1 8.8 3.8 5.6 1 8.4 3.4 70 8 73 165 9.2 0 9.3 8.8 09/10/2006 02:10:00 5.3 0.8 7.2 2.6 5.4 0.8 7.2 3 5.2 0.7 6.8 3.4 64 8 71 165 9.2 0 9.3 9 09/10/2006 02:20:00 5 0.9 7.2 3 5.2 0.9 7.6 3 5.1 0.8 7.2 3.4 61 8 54 165 9.2 0 9.3 9 09/10/2006 02:30:00 5.3 1 7.2 3 5.5 1 7.6 3 5.2 0.9 7.6 3 63 8 64 165 9.2 0 9.3 9 09/10/2006 02:40:00 5.7 1 8.8 3.8 5.8 1.1 8.8 3.8 5.5 1 8.4 3.4 66 9 65 165 9.3 0 9.3 9 09/10/2006 02:50:00 6.1 0.8 8 4.2 6.2 0.9 8.8 4.2 5.9 0.8 8 3.8 61 9 76 165 9.3 0 9.3 9 09/10/2006 03:00:00 6 0.8 8 4.2 6.1 0.8 8 4.2 5.8 0.8 8 3.8 61 9 77 165 9.2 0 9.3 9 09/10/2006 03:10:00 5.8 0.9 8 3.8 5.9 1 8.4 3.8 5.7 0.8 8 3.8 58 9 63 165 9.2 0 9.3 9 09/10/2006 03:20:00 5.5 0.8 7.2 3.4 5.6 0.8 7.6 3.8 5.4 0.8 7.6 3.8 61 9 55 165 9.3 0 9.3 9 09/10/2006 03:30:00 5.6 0.9 8.8 3.8 5.7 0.9 8.8 3.8 5.5 0.7 7.6 3.8 62 8 45 165 9.3 0 9.3 9 09/10/2006 03:40:00 5.4 1.1 8 3 5.5 1.2 8 3 5.4 1.1 7.6 3 61 10 87 165 9.4 0 9.6 9 09/10/2006 03:50:00 6.1 0.9 8 3.8 6.3 1 8.4 3.8 5.9 1 8 3.8 65 9 68 165 9.3 0 9.3 9 09/10/2006 04:00:00 5.2 0.9 7.2 3.4 5.3 0.9 6.8 3 5.2 0.8 7.2 3.4 65 9 66 165 9.3 0 9.6 9 09/10/2006 04:10:00 5.6 0.9 7.6 3.4 5.6 1 8 3.4 5.4 0.8 7.6 3.4 59 9 57 165 9.3 0 9.3 9 09/10/2006 04:20:00 6.7 1 8.8 3.4 6.8 1 8.8 3.4 6.5 0.9 8.4 3.8 64 11 62 165 9.2 0 9.3 9 09/10/2006 04:30:00 6.2 1.3 8.8 3 6.4 1.4 8.8 2.6 6.2 1.2 8.4 3.4 65 10 69 165 9.2 0 9.6 9 09/10/2006 04:40:00 7.1 1 9.1 4.2 7.2 1.1 9.1 4.2 6.9 1 8.8 4.6 66 6 70 165 9.2 0 9.3 9 09/10/2006 04:50:00 6.9 0.9 9.1 4.9 7 0.9 9.1 4.9 6.8 0.8 8.8 4.2 59 9 46 165 9.2 0 9.3 8.8 09/10/2006 05:00:00 6.2 0.9 8.8 4.2 6.3 0.9 8.8 4.2 6.2 0.8 8 4.2 60 9 47 165 9.2 0 9.6 9 09/10/2006 05:10:00 6.6 1.2 9.5 3.8 6.8 1.2 9.9 3.8 6.5 1.1 9.1 3.8 60 10 49 165 9.3 0 9.3 9 09/10/2006 05:20:00 6.1 0.9 8.4 4.2 6.2 1 8.8 4.2 6.1 1 9.1 3.4 63 10 77 165 9.3 0 9.3 9 09/10/2006 05:30:00 6.8 1 9.1 3.8 6.9 1 9.1 3.4 6.6 0.9 9.1 4.2 58 8 52 165 9.2 0 9.3 9 09/10/2006 05:40:00 4.8 1.1 8 2.6 4.9 1.2 7.6 2.6 4.9 1 7.2 3 55 10 58 165 9.2 0 9.3 9 09/10/2006 05:50:00 5.9 1.1 8.8 3.8 6 1.2 8.8 3.8 5.8 1.1 8.8 3.8 54 8 53 165 9.2 0 9.3 9 09/10/2006 06:00:00 5.2 1.1 8.4 3 5.2 1.2 8 3 5 1.1 8.4 2.6 59 11 41 165 9.3 0 9.6 9 09/10/2006 06:10:00 5.8 1.1 8.8 3.4 5.9 1.2 8.8 3.8 5.7 1.1 8.4 3.8 64 8 68 165 9.3 0 9.6 9 09/10/2006 06:20:00 5.6 1 9.1 3.8 5.7 1 8.8 3.8 5.6 1 8.8 3 65 9 60 165 9.3 0 9.6 9 09/10/2006 06:30:00 5.3 0.9 7.6 3.4 5.3 0.9 8 3.4 5.2 0.9 8 3.4 59 9 60 165 9.3 0 9.6 9 09/10/2006 06:40:00 5.1 1 7.6 3 5.2 1 8 2.6 5.2 0.9 7.2 3 63 11 52 165 9.4 0 9.6 9 09/10/2006 06:50:00 6.4 1 9.5 3.8 6.5 1 9.5 3.8 6.1 1 9.1 3.8 56 9 68 165 9.3 0 9.3 9 09/10/2006 07:00:00 6.9 1.3 9.1 3.8 7.1 1.3 9.1 4.2 6.7 1.3 8.8 3.8 68 10 78 165 9.2 0.1 9.8 9 09/10/2006 07:10:00 4.8 1 7.2 2.3 4.9 1 7.2 2.6 4.8 0.8 6.8 2.6 65 10 62 165 9.4 0 9.6 9 09/10/2006 07:20:00 5.3 1 9.1 3 5.2 1 8.4 3 5.2 1 7.6 3 46 20 22 165 9.5 0 9.6 9.3 09/10/2006 07:30:00 6.8 1 9.9 3.8 6.4 1.1 9.5 3 6.5 1 9.5 3.8 21 8 23 165 9.4 0 9.6 9.3 09/10/2006 07:40:00 6.8 1.1 9.5 4.2 6.4 1.2 9.5 2.6 6.6 1.1 9.5 4.2 22 8 18 165 9.5 0 9.6 9 09/10/2006 07:50:00 6.2 0.9 8.8 4.2 6.1 1 8.4 3.8 6.2 0.8 8.4 3.4 27 8 28 165 9.6 0.1 9.6 9 09/10/2006 08:00:00 5.8 0.9 8 3.8 5.7 0.9 8 3.8 5.7 0.9 8.4 3.8 30 8 29 165 9.6 0.1 9.6 9 09/10/2006 08:10:00 6 0.9 8.8 3.4 5.9 1 8.8 3.4 5.8 0.8 8 3.4 32 9 23 165 9.6 0.1 9.6 9 09/10/2006 08:20:00 5.9 1 8 3 5.8 1 8.4 3 5.9 1.1 8.4 3.4 34 9 40 165 9.6 0.1 9.6 9 09/10/2006 08:30:00 5.8 0.8 8 4.2 5.6 0.9 7.6 3.4 5.8 0.9 8 3.8 27 9 38 165 9.5 0 9.6 9 09/10/2006 08:40:00 6.3 1.2 9.9 3.8 6.1 1.3 9.9 3 6.3 1.2 9.9 4.2 27 8 25 165 9.5 0 9.6 9 09/10/2006 08:50:00 6.7 1.1 9.1 4.2 6.6 1.1 9.1 3.8 6.7 1 9.5 4.2 26 7 37 165 9.4 0 9.6 8.8 09/10/2006 09:00:00 6.9 1.1 9.1 4.2 6.8 1.1 9.1 4.2 6.9 1 9.1 4.6 32 8 28 165 9.3 0 9.6 8.8 09/10/2006 09:10:00 6.2 0.8 8.8 4.6 6.2 0.8 8.8 4.2 6.2 0.8 8.4 4.6 39 6 40 165 9.3 0 9.3 8.8 09/10/2006 09:20:00 5.6 0.9 7.6 3.4 5.5 0.9 7.6 3.4 5.7 0.8 8 3.8 37 8 39 165 9.4 0 9.6 8.8 09/10/2006 09:30:00 6 0.9 8 3.8 5.9 0.9 8 3.4 6.1 0.9 8 3.4 38 9 52 165 9.6 0.1 9.6 9 09/10/2006 09:40:00 6 0.9 8.8 3.4 5.8 0.9 8.8 3 6 0.8 8.4 3.8 32 8 35 165 9.6 0 9.6 8.8 09/10/2006 09:50:00 6.4 0.8 8.4 4.2 6.3 0.8 8.4 3.8 6.2 0.8 8.4 4.2 34 7 39 165 9.2 0 9.6 8.5 09/10/2006 10:00:00 5.7 1 8.8 3.8 5.6 1 8.4 3.8 5.7 0.9 8 3.8 32 9 34 165 9.6 0.1 9.8 9 09/10/2006 10:10:00 5.4 1 8.4 3 5.4 1 8.4 3 5.4 1 8.4 3.4 33 9 44 165 9.6 0.1 9.8 9 09/10/2006 10:20:00 4 1 6.5 1.9 3.9 1 6.5 1.5 4.1 1 6.5 2.3 45 13 51 165 9.8 0 10.1 9.3 09/10/2006 10:30:00 4.8 1.3 8.4 1.5 4.7 1.3 8 1.1 4.8 1.1 8 1.5 42 17 22 165 9.9 0 10.1 9.3 09/10/2006 10:40:00 5.7 1.1 8.4 3 5.6 1.2 8.4 3 5.5 1.1 8.4 3 33 13 27 165 9.8 0 10.1 9.3 09/10/2006 10:50:00 4.7 1.2 7.6 2.3 4.6 1.2 7.6 2.3 4.5 1.1 8 2.3 35 12 39 165 10 0 10.3 9.6 09/10/2006 11:00:00 4.7 0.8 6.5 3 4.6 0.8 6.8 2.6 4.7 0.8 8 3 55 14 48 165 10 0 10.3 9.6 09/10/2006 11:10:00 5.9 1.2 9.1 3.4 6 1.3 9.5 3.4 5.8 1.2 9.1 3 64 13 70 165 10.3 0 10.9 9.8 09/10/2006 11:20:00 5.8 1 8.4 3 5.9 1.1 8.4 3 5.7 1.1 8.4 3 66 15 55 165 10.6 0.2 10.9 10.3 09/10/2006 11:30:00 6.1 0.8 8 3.8 6.2 0.9 8.4 3.8 6.1 0.8 8.4 3.8 70 12 65 165 10.8 0.2 11.1 10.3 09/10/2006 11:40:00 7 1 9.1 3.8 7 1 9.1 3.8 6.9 1 9.1 4.6 62 10 58 165 10.6 0.2 10.9 10.3 09/10/2006 11:50:00 5.5 0.9 8 3.4 5.5 1 8 3 5.4 1.1 8.8 2.6 58 14 70 165 10.9 0.1 11.1 10.3 09/10/2006 12:00:00 5.3 1.1 8.4 2.6 5.3 1.2 8.4 2.6 5.3 1.1 8.4 3.4 59 12 67 165 10.9 0 11.1 10.9 09/10/2006 12:10:00 5.7 1.1 8.4 3.4 5.7 1.2 8.4 3 5.7 1.1 8.8 2.6 59 13 54 165 11 0.2 11.7 10.6 09/10/2006 12:20:00 5.1 1.3 8 1.9 5.1 1.3 8 1.9 5 1.1 8 2.6 50 15 73 165 11.1 0.1 11.4 10.9 09/10/2006 12:30:00 5.4 1.2 8.4 2.6 5.4 1.3 8.8 2.3 5.3 1.1 8 2.6 57 14 68 165 10.9 0.3 11.9 10.6 09/10/2006 12:40:00 5.1 1.1 8.4 3 4.9 1.1 8.4 2.6 5 1 8 3 36 12 34 165 11.1 0.4 12.2 10.6 09/10/2006 12:50:00 5.6 1 7.6 3 5.4 1 7.6 2.6 5.4 1.1 7.6 2.3 36 12 46 165 10.8 0.2 11.1 10.6 09/10/2006 13:00:00 6 1 9.1 3.8 5.7 1 8.4 3 5.8 1 8.4 3.4 30 10 23 165 10.4 0 10.9 10.3 09/10/2006 13:10:00 5.4 1 8 3 5.2 1.1 8 2.6 5.2 1.1 8.4 2.6 34 10 29 165 10.7 0 11.1 10.6 09/10/2006 13:20:00 5.8 1 8 3.8 5.7 1 7.6 3.4 5.7 1 8 3.8 31 9 21 165 10.6 0 10.9 10.3 09/10/2006 13:30:00 6.2 0.8 7.6 3.4 6.1 0.8 7.6 3.4 6.2 0.8 8 4.2 34 5 29 165 10.7 0 11.1 10.6 09/10/2006 13:40:00 6.1 0.7 7.6 3.8 6 0.8 7.6 3.4 6.1 0.7 7.6 3.8 32 6 36 165 10.6 0.1 11.1 10.3 09/10/2006 13:50:00 5.8 0.8 7.6 3.4 5.7 0.9 7.6 3.4 5.8 0.8 7.6 3.4 30 10 34 165 11.1 0.1 11.4 10.9 09/10/2006 14:00:00 6.5 1 8.8 4.2 6.2 1.2 8.4 3 6.5 1 8.8 3.8 25 9 27 165 10.8 0 11.1 10.6 09/10/2006 14:10:00 5.9 1 7.6 3.8 5.7 1 7.6 3.4 5.8 0.9 7.6 3.8 27 9 33 165 11.2 0 11.7 10.3 09/10/2006 14:20:00 6.7 0.9 8.4 3.8 6.4 1 8.4 3.4 6.8 1 9.1 4.6 24 9 39 165 11.1 0 11.4 10.3 09/10/2006 14:30:00 6.7 1.1 8.8 4.2 6.4 1.2 8.8 3.8 6.7 1.1 9.1 3.8 25 8 31 165 10.7 0.1 11.1 10.3 09/10/2006 14:40:00 6.9 0.9 8.8 4.2 6.7 1 8.8 3.4 7 0.9 8.8 4.9 27 9 31 165 10.7 0.1 11.1 10.6 09/10/2006 14:50:00 7 1 9.9 4.2 6.9 1 9.1 4.2 6.9 1 9.1 3.8 29 8 19 165 10.5 0 10.9 10.3 09/10/2006 15:00:00 7 0.8 9.1 5.3 6.9 0.8 9.1 4.9 6.9 0.9 9.5 4.9 31 9 41 165 10.7 0.1 11.1 10.3 09/10/2006 15:10:00 6.5 1 9.9 4.2 6.3 1.1 9.5 3.8 6.3 1 8.8 3.8 32 9 43 165 10.2 0.2 10.9 9.6 09/10/2006 15:20:00 6.2 1 8.4 3.8 6 1 8.8 3.4 6 1 8.8 3.8 27 10 13 165 10.3 0 10.6 9.8 09/10/2006 15:30:00 6.5 1 9.1 3.8 6.3 1.2 9.1 2.6 6.5 1.1 9.5 4.2 27 9 34 165 10.2 0 10.6 9.8 09/10/2006 15:40:00 6.6 1 9.5 3.8 6.3 1.1 9.1 3.4 6.4 1 9.5 3.8 26 9 29 165 10.3 0 10.6 10.1 09/10/2006 15:50:00 7.2 1 9.5 4.2 7 1.2 9.5 3.8 7.2 1 9.1 4.2 26 9 44 165 10.1 0.1 10.3 9.8 09/10/2006 16:00:00 6.3 1 9.5 3.8 6.2 1 9.5 3.8 6.2 0.9 8.8 4.2 28 9 29 165 10.1 0.2 10.6 9.6 09/10/2006 16:10:00 6.4 1.1 8.8 3.8 6.2 1.1 8.8 3 6.2 1.1 9.1 2.6 29 9 16 165 10.3 0 10.6 10.1 09/10/2006 16:20:00 6.3 1 8.8 3.8 6.1 1 8.8 3.4 6.1 1 8.8 3.8 28 9 19 165 10.3 0.1 10.6 9.8 09/10/2006 16:30:00 6 1.1 8.8 3.8 5.8 1.1 9.1 2.6 5.8 1 8.8 3.8 27 11 19 165 10.3 0.1 10.6 9.8 09/10/2006 16:40:00 6.2 1.1 9.5 3.4 6 1.1 9.5 3.4 5.9 1 8 3.4 26 9 19 165 10.3 0.1 10.6 9.8 09/10/2006 16:50:00 6 1.2 8.8 3 5.7 1.2 8.8 2.6 5.9 1.2 9.1 3 23 11 34 165 10.5 0.2 10.9 10.1 09/10/2006 17:00:00 6.9 1.3 10.3 3.8 6.4 1.3 9.9 3.8 6.3 1.4 9.9 3 20 10 26 165 10.4 0.1 10.9 9.8 09/10/2006 17:10:00 7.2 1.2 10.7 4.6 6.8 1.3 11.1 3.4 7 1.2 11.1 4.6 20 11 29 165 10.1 0.2 10.6 9.6 09/10/2006 17:20:00 6.1 0.9 8.4 3.8 5.7 1 8.8 3 6.1 0.8 8.4 3.4 22 9 31 165 10.1 0.1 10.6 9.8 09/10/2006 17:30:00 6.2 0.9 8.4 4.2 5.9 1 8 3.4 6.3 0.8 8.4 4.2 26 9 18 165 10.2 0.1 10.9 9.8 09/10/2006 17:40:00 6.1 0.9 8.4 3.8 5.8 1 8.4 3 6 1 8.8 3.8 26 8 31 165 10.1 0.1 10.3 9.6 09/10/2006 17:50:00 6.6 0.9 8.4 4.2 6.1 1 8.8 3.4 6.5 1 8.4 4.2 20 9 14 165 10.1 0 10.6 9.6 09/10/2006 18:00:00 8.4 1.2 11.8 5.3 7.7 1.3 11.5 4.2 8.1 1.2 11.8 5.3 16 9 12 165 10.1 0 10.3 10.1 09/10/2006 18:10:00 7.4 1.1 9.9 4.2 7 1.2 9.9 2.6 7.2 1 9.9 4.6 23 9 16 165 10.1 0 10.3 9.8 09/10/2006 18:20:00 7.7 1 10.3 4.9 7.3 1.1 9.9 4.6 7.5 1.1 9.9 4.9 21 8 22 165 10 0 10.6 9.8 09/10/2006 18:30:00 7.9 0.9 10.7 5.7 7.4 1.1 10.3 4.6 7.8 1 9.9 5.7 20 8 25 165 10 0 10.6 9.6 09/10/2006 18:40:00 7.2 1 9.9 4.2 6.9 1.1 9.5 3 6.9 1.1 9.5 4.2 25 9 16 165 10.1 0 10.3 9.8 09/10/2006 18:50:00 6.9 1.2 9.5 4.2 6.8 1.2 9.5 4.2 6.9 1.2 9.5 4.2 27 9 31 165 10.1 0 10.3 9.8 09/10/2006 19:00:00 6.3 0.8 8.4 3.8 6.2 0.9 8.4 3.4 6.3 0.9 8.4 4.2 28 8 18 165 10 0 10.6 9.6 09/10/2006 19:10:00 6.1 1.2 9.1 3.8 5.9 1.1 8.8 3.8 6 1 9.1 3.8 28 9 20 165 10 0 10.3 9.6 09/10/2006 19:20:00 6.8 1 9.1 4.6 6.3 1.1 9.5 3.4 6.7 1 9.5 4.6 21 9 17 165 10 0 10.1 9.6 09/10/2006 19:30:00 6.4 1 9.5 3.8 6 1.1 9.5 3.4 6.4 1 9.1 3.8 21 10 23 165 10 0 10.3 9.6 09/10/2006 19:40:00 6.2 1 9.1 4.2 5.7 1.1 9.1 3.4 6 0.9 8.8 3.8 19 9 33 165 10 0 10.3 9.6 09/10/2006 19:50:00 7 1.3 9.9 3.4 6.3 1.3 9.1 3.4 6.8 1.1 9.5 3.8 17 8 15 165 10 0 10.6 9.6 09/10/2006 20:00:00 7.5 1 10.3 4.6 6.4 1 8.8 3.4 7.2 1.1 9.9 4.9 13 8 12 165 9.9 0 10.3 9.6 09/10/2006 20:10:00 7.6 1 10.3 5.3 6.6 1.1 9.1 3.8 7.2 1 9.9 4.2 13 8 9 165 9.9 0 10.1 9.6 09/10/2006 20:20:00 7.1 1 9.5 4.6 6.5 1.1 9.1 3.4 6.9 1 9.5 4.2 19 11 1 165 9.8 0 10.1 9.6 09/10/2006 20:30:00 7.9 0.9 10.7 5.7 7.2 1.2 9.9 3.8 7.7 1 10.3 5.3 18 8 19 165 9.9 0 10.1 9.3 09/10/2006 20:40:00 8 1.1 10.7 5.3 7.2 1.3 10.3 4.2 7.7 1.1 11.1 4.9 16 8 17 165 9.9 0 10.1 9.6 09/10/2006 20:50:00 6.7 1.1 9.5 4.2 6 1.2 9.1 3 6.5 1 9.1 3.8 16 8 7 165 9.8 0 10.1 9.3 09/10/2006 21:00:00 7.6 1.2 10.7 4.9 6.7 1.3 9.9 3.4 7.3 1.1 10.7 4.6 13 9 12 165 9.8 0 10.3 9.6 09/10/2006 21:10:00 6.6 1.2 9.5 3.8 6.3 1.2 9.5 3.4 6.4 1 9.1 4.2 23 10 36 165 9.8 0 10.1 9.6 09/10/2006 21:20:00 6.5 1.2 9.5 4.2 6.1 1.1 9.5 3 6.3 1.1 9.1 3.4 22 9 29 165 9.8 0 10.1 9.6 09/10/2006 21:30:00 6.3 1.2 9.5 3.8 5.9 1.2 9.1 3.4 6.1 1.2 9.1 3.8 19 9 29 165 9.8 0 10.1 9.3 09/10/2006 21:40:00 6.3 1.1 9.1 3.4 5.8 1.1 8.8 2.6 5.9 1 9.9 3.4 17 10 18 165 9.8 0 10.1 9.3 09/10/2006 21:50:00 7.7 1.3 11.5 4.2 7.1 1.3 10.7 4.6 7.2 1.3 10.7 3.4 17 9 10 165 9.8 0 10.1 9.3 09/10/2006 22:00:00 7.2 1.3 10.7 4.6 6.7 1.2 9.9 3.8 6.9 1.3 11.5 3.8 18 9 345 165 9.8 0 10.1 9.3 09/10/2006 22:10:00 7.8 1 10.3 4.6 7.4 1.1 9.9 3.8 7.6 1 10.7 4.9 19 8 20 165 9.8 0 10.1 9.3 09/10/2006 22:20:00 7.4 1.4 10.7 3.8 6.9 1.5 10.7 3.8 6.9 1.3 9.9 4.2 18 10 19 165 9.8 0 10.1 9.3 09/10/2006 22:30:00 7.5 1.2 10.7 4.9 7 1.3 10.7 3.4 7.2 1.1 10.7 4.2 19 9 15 165 9.8 0.1 10.3 9.3 09/10/2006 22:40:00 7.8 1.2 10.3 4.9 7.2 1.3 10.3 4.2 7.6 1.1 10.3 4.6 17 8 23 165 9.8 0 9.8 9.3 09/10/2006 22:50:00 7.7 1.1 9.9 4.9 7.3 1.3 10.3 3.4 7.3 1.1 9.9 4.6 21 8 29 165 9.8 0 10.3 9.3 09/10/2006 23:00:00 8 1 10.3 4.9 7.6 1.2 10.3 3 7.7 1.1 10.3 5.3 20 7 18 165 9.8 0 10.1 9.3 09/10/2006 23:10:00 7 1.1 9.5 4.6 6.7 1.2 9.9 3.8 6.8 1.1 9.5 4.6 23 9 29 165 9.9 0 10.1 9.3 09/10/2006 23:20:00 6.9 1.1 9.9 4.2 6.4 1.2 9.5 3.4 6.9 1.1 10.7 4.2 20 8 18 165 9.8 0 10.1 9.3 09/10/2006 23:30:00 6.8 1 9.1 4.6 6.3 1.1 9.1 3.4 6.7 0.9 8.8 4.6 18 8 18 165 9.8 0 10.1 9.3 09/10/2006 23:40:00 8.3 0.8 10.3 6.5 7.7 1 9.9 4.2 8 1 10.7 5.3 18 7 6 165 9.8 0 10.1 9.3 09/10/2006 23:50:00 7.1 1 9.5 4.6 6.7 1 9.1 4.2 7 1 9.9 4.2 19 8 20 165 9.8 0 9.8 9.3 09/11/2006 00:00:00 7.3 1 9.9 5.3 6.7 1.1 9.5 3 7 1 9.9 5.3 17 8 19 165 9.8 0 10.1 9.3 09/11/2006 00:10:00 7.5 1 9.9 5.3 7.2 1.1 9.5 3.4 7.2 1.1 10.3 4.9 21 9 9 165 9.8 0 9.8 9.3 09/11/2006 00:20:00 6.9 1 9.1 4.2 6.7 1 9.1 3.8 6.7 1 9.1 4.2 24 8 25 165 9.8 0 9.8 9.3 09/11/2006 00:30:00 6.7 1.1 9.5 3.8 6.4 1.1 9.5 3.4 6.5 1 9.1 4.2 23 10 28 165 9.8 0 9.8 9.3 09/11/2006 00:40:00 8.3 1.3 11.8 4.6 8 1.5 11.8 4.2 8 1.3 11.5 3.8 21 9 21 165 9.8 0 9.8 9.3 09/11/2006 00:50:00 8.4 1.3 11.5 4.9 8.2 1.3 11.8 4.9 8.1 1.2 11.8 4.9 25 8 36 165 9.8 0 9.8 9.3 09/11/2006 01:00:00 8.9 1 11.8 6.5 8.6 1.1 11.5 5.7 8.4 1.1 11.5 5.7 22 8 13 165 9.9 0 10.1 9.3 09/11/2006 01:10:00 8.3 1.2 11.5 4.9 8 1.3 11.5 4.2 8 1.3 11.5 4.6 23 9 23 165 9.9 0 10.1 9.3 09/11/2006 01:20:00 7.1 1.3 10.7 4.2 7 1.3 10.3 3.4 6.9 1.2 10.3 3.8 34 11 34 165 9.8 0 10.1 9.3 09/11/2006 01:30:00 6.5 1.2 9.1 3.4 6.4 1.2 9.1 3 6.4 1.3 9.5 3 38 9 31 165 9.8 0.1 10.6 9.3 09/11/2006 01:40:00 7.8 1.2 11.1 4.9 7.6 1.3 10.3 4.6 7.5 1.3 10.7 4.6 28 9 35 165 9.8 0.1 10.1 9.3 09/11/2006 01:50:00 7.5 1.3 11.1 4.2 7.1 1.3 11.5 3.8 7.1 1.2 11.1 4.6 25 12 30 165 9.8 0.1 10.1 9.3 09/11/2006 02:00:00 7.4 1 10.3 5.3 7.3 1 9.9 5.3 7.2 0.9 10.3 4.9 35 8 27 165 9.8 0.1 10.1 9.3 09/11/2006 02:10:00 8.2 0.9 10.3 6.1 8 1 10.3 5.7 7.9 1 10.3 5.7 35 7 31 165 9.8 0.1 10.3 9.3 09/11/2006 02:20:00 7.4 1 9.5 4.6 7.2 1 9.9 4.6 7.1 1 9.9 4.2 33 8 31 165 9.8 0.1 10.1 9.3 09/11/2006 02:30:00 6.9 1.1 10.3 4.2 6.8 1.1 10.3 4.2 6.6 1.2 10.3 3.8 34 8 36 165 9.8 0.1 10.1 9.3 09/11/2006 02:40:00 6.7 1.2 9.9 3.8 6.5 1.2 10.3 3.8 6.6 1.1 9.5 3.8 32 9 32 165 9.8 0.1 10.3 9.3 09/11/2006 02:50:00 7.7 1 9.9 4.6 7.5 1 9.9 4.6 7.4 1 9.5 4.9 31 8 21 165 9.8 0.1 10.1 9.3 09/11/2006 03:00:00 7.4 1.2 9.9 4.2 7.3 1.2 9.9 4.2 7.2 1.3 9.9 4.6 30 8 29 165 9.8 0.1 10.3 9.3 09/11/2006 03:10:00 7.7 1.1 10.3 4.6 7.6 1.2 10.7 4.2 7.4 1.1 11.1 4.6 32 8 40 165 9.8 0.1 10.1 9.3 09/11/2006 03:20:00 8 1 10.7 4.9 8 1.1 10.7 4.9 7.8 1 9.9 4.9 30 7 20 165 9.8 0.1 10.1 9.3 09/11/2006 03:30:00 8.1 0.9 10.3 5.3 8 1 10.3 5.3 8 1 10.3 5.3 30 7 34 165 9.8 0.1 9.8 9.3 09/11/2006 03:40:00 7 1 9.1 4.6 6.9 1 9.1 4.2 6.6 1 9.5 4.2 29 8 29 165 9.8 0 9.8 9.3 09/11/2006 03:50:00 7 0.9 8.8 4.2 6.9 1 8.8 3.8 7 0.9 9.1 4.2 26 8 25 165 9.8 0 9.8 9.3 09/11/2006 04:00:00 7 1 9.9 4.6 6.8 1.1 9.5 3.8 7 1 9.1 4.6 25 7 29 165 9.8 0 9.8 9.3 09/11/2006 04:10:00 6.4 1 9.1 3.8 6.1 1 8.8 3.4 6.2 0.9 8.8 4.6 24 9 17 165 9.8 0 9.8 9.3 09/11/2006 04:20:00 6.9 1 9.5 4.2 6.5 1.1 9.5 3.8 6.8 1 9.1 4.6 23 9 27 165 9.8 0 9.8 9.3 09/11/2006 04:30:00 7 1.1 10.7 4.6 6.6 1.2 11.1 3.4 6.8 1.1 9.5 4.2 21 8 21 165 9.8 0 9.8 9.3 09/11/2006 04:40:00 7.6 1.2 11.1 4.9 7 1.3 10.3 3.8 7.3 1.1 10.7 4.9 18 8 19 165 9.8 0 9.8 9.3 09/11/2006 04:50:00 8.2 1.1 11.1 5.3 7.4 1.2 10.7 4.9 8.1 1.2 11.5 4.9 16 8 16 165 9.8 0 9.8 9 09/11/2006 05:00:00 8.3 1.2 11.1 6.1 7.3 1.4 10.7 3.8 8 1 10.7 4.6 14 8 15 165 9.8 0 10.3 9.3 09/11/2006 05:10:00 8.2 1 11.1 6.1 7.3 1.3 10.3 4.2 8 1 11.5 6.1 16 8 17 165 9.8 0 9.8 9 09/11/2006 05:20:00 8 1.1 10.7 5.3 7.3 1.2 10.7 4.2 7.8 1 10.7 5.3 18 7 26 165 9.8 0 9.8 9.3 09/11/2006 05:30:00 7.7 0.8 9.9 5.7 6.6 1.1 9.9 3.8 7.6 0.8 10.3 5.3 14 7 23 165 9.8 0 10.1 9.3 09/11/2006 05:40:00 8.6 1.1 11.1 6.1 7.4 1.3 10.3 3.8 8.3 1.1 11.1 5.7 14 8 19 165 9.8 0 9.8 9.3 09/11/2006 05:50:00 7.7 1.1 10.7 4.9 6.9 1.2 10.3 3 7.5 1 11.1 4.9 15 7 1 165 9.8 0 9.8 9.3 09/11/2006 06:00:00 8.4 1 11.5 5.7 7.8 1.2 11.5 3.8 8.3 1 11.5 5.7 17 6 23 165 9.7 0.1 9.8 9 09/11/2006 06:10:00 8.8 1 11.1 5.3 7.8 1.2 10.3 4.9 8.4 1 11.1 5.7 14 7 15 165 9.7 0.1 9.8 9 09/11/2006 06:20:00 8.1 0.9 10.3 6.1 6.6 1.1 10.3 3.8 7.9 0.8 9.9 5.3 11 7 23 165 9.6 0.1 9.8 9 09/11/2006 06:30:00 8.1 1.2 11.5 5.7 6.8 1.3 10.7 3.4 7.8 1.1 11.5 4.9 13 7 16 165 9.6 0.1 9.8 9 09/11/2006 06:40:00 8 0.9 9.9 5.7 6.9 1.1 9.5 3.8 7.7 0.9 9.9 5.3 13 8 16 165 9.6 0.1 9.8 9 09/11/2006 06:50:00 8.5 1.1 11.1 5.7 7.8 1.4 10.7 3.4 8.2 1.2 11.1 5.3 17 9 12 165 9.6 0.1 9.8 9 09/11/2006 07:00:00 7.9 1 9.9 5.7 7 1.1 9.5 3.8 7.6 1 10.3 5.3 15 7 6 165 9.6 0.1 9.6 9 09/11/2006 07:10:00 7.2 1.3 11.1 4.6 6.4 1.3 10.3 2.6 7 1.2 10.3 4.2 14 8 10 165 9.6 0.1 9.8 9 09/11/2006 07:20:00 7.4 1 10.3 4.9 6.4 1.2 9.5 3.4 7.2 1.1 10.7 4.9 12 8 13 165 9.6 0 9.8 9 09/11/2006 07:30:00 8.9 1.2 11.8 6.1 7.6 1.4 11.5 4.2 8.6 1.3 11.8 5.3 11 7 25 165 9.7 0.1 9.8 9 09/11/2006 07:40:00 8.5 1 11.5 6.1 7.2 1.2 10.3 4.2 8 1 11.1 5.3 10 8 12 165 9.7 0.2 9.8 9 09/11/2006 07:50:00 9.8 1.1 13 6.1 8 1.4 12.6 4.9 9.3 1.3 12.2 6.1 9 7 11 165 9.7 0.2 9.8 9 09/11/2006 08:00:00 9.3 1.1 11.8 6.5 8 1.4 11.5 4.6 8.9 1.2 11.8 5.7 12 9 18 165 9.8 0.2 10.3 9 09/11/2006 08:10:00 9.5 1.5 13.7 5.7 8.6 1.8 13 3.8 9.2 1.5 12.6 6.1 16 9 19 165 9.8 0.1 10.1 9.3 09/11/2006 08:20:00 8.3 1 11.1 5.7 7.7 1.3 10.7 3.4 8.1 1.2 10.7 4.9 17 8 24 165 10 0 10.3 9.3 09/11/2006 08:30:00 8 1.2 10.7 5.3 7.6 1.3 10.7 4.2 7.6 1.2 10.7 5.3 19 9 19 165 10 0 10.3 9.6 09/11/2006 08:40:00 8.6 1.3 11.8 5.3 8.4 1.4 11.8 4.9 8.3 1.3 11.8 5.3 23 8 18 165 10.1 0.1 10.3 9.6 09/11/2006 08:50:00 8.4 1 10.7 5.3 8.2 1.1 10.3 4.9 8.1 1 10.7 5.3 21 7 29 165 10.2 0 10.6 9.8 09/11/2006 09:00:00 9.4 1.1 11.8 6.5 9 1.2 11.5 4.9 9 1.2 11.8 5.7 19 7 16 165 10.2 0 10.9 9.8 09/11/2006 09:10:00 9.2 1.2 12.2 5.7 8.8 1.3 12.2 4.6 8.8 1.2 12.6 4.9 21 9 21 165 10.4 0 10.6 10.1 09/11/2006 09:20:00 9.2 1.3 11.8 5.7 8.9 1.5 11.5 4.6 9.1 1.3 11.8 5.7 21 7 19 165 10.2 0 10.6 9.8 09/11/2006 09:30:00 9.5 1 11.5 6.8 8.9 1.3 11.5 4.6 9.2 1 11.5 6.5 19 7 19 165 10.5 0 10.6 10.1 09/11/2006 09:40:00 9.1 1 11.5 6.1 8.7 1.1 10.7 5.7 8.7 1.1 11.5 5.7 20 6 8 165 10.5 0 10.9 10.1 09/11/2006 09:50:00 8 0.8 10.3 5.3 6.9 1 9.5 3.4 7.8 0.8 9.9 5.3 14 7 12 165 10.7 0.1 10.9 10.3 09/11/2006 10:00:00 8.4 0.9 10.3 4.9 7.4 1.1 9.5 4.2 8.2 1 10.3 5.3 15 6 6 165 10.5 0.2 10.9 9.8 09/11/2006 10:10:00 8.1 0.8 9.9 5.7 7.2 1.2 9.5 3.8 7.9 0.9 9.9 5.3 16 8 20 165 10.6 0.2 11.1 10.1 09/11/2006 10:20:00 8.2 0.8 9.9 5.3 7.9 1 9.5 4.2 7.9 0.9 9.5 5.3 21 7 21 165 10.9 0.2 11.4 10.3 09/11/2006 10:30:00 8 1 10.3 5.3 7.8 1 10.7 5.3 7.8 1 9.9 5.3 23 6 24 165 11.1 0 11.4 10.9 09/11/2006 10:40:00 8.4 1 10.7 4.9 8.1 1.1 10.7 4.9 7.9 1.2 10.7 4.9 24 7 26 165 11.2 0 11.4 10.9 09/11/2006 10:50:00 8.5 1 11.5 5.7 8.3 1 11.5 5.3 8 1 10.7 5.3 25 7 39 165 11.4 0 11.7 11.1 09/11/2006 11:00:00 7.2 1.1 10.3 4.9 7 1.2 10.3 4.2 7 1.1 9.9 4.2 26 9 25 165 11.3 0 11.4 11.1 09/11/2006 11:10:00 8.3 1.3 11.5 5.3 8.2 1.3 11.5 4.9 7.9 1.3 11.5 5.3 29 9 28 165 11.1 0 11.4 10.9 09/11/2006 11:20:00 9 1.1 11.8 6.5 8.8 1.2 11.8 5.3 8.7 1.1 11.5 5.3 29 9 20 165 10.8 0.1 11.1 10.6 09/11/2006 11:30:00 9 1.3 12.6 5.3 8.8 1.4 13 4.6 8.8 1.2 11.8 5.7 26 9 29 165 10.7 0 11.1 10.6 09/11/2006 11:40:00 8.6 1.3 12.2 5.7 8.4 1.3 12.2 4.9 8.3 1.2 11.1 5.3 25 9 25 165 10.7 0 10.9 10.6 09/11/2006 11:50:00 8.8 1.2 11.8 5.7 8.5 1.3 11.5 4.9 8.5 1.1 11.1 5.7 25 8 22 165 10.8 0.2 11.4 10.3 09/11/2006 12:00:00 8.5 1.2 11.1 5.7 8.2 1.3 11.1 4.9 8.3 1.2 11.1 4.9 24 8 31 165 11.5 0.2 11.9 11.1 09/11/2006 12:10:00 8.7 1 11.1 5.7 8.4 1.2 10.7 4.9 8.5 1.1 11.1 5.7 23 7 32 165 11.8 0.1 12.2 11.4 09/11/2006 12:20:00 8.1 0.9 10.3 4.9 7.7 1.1 10.3 4.6 7.9 1 10.7 5.3 21 8 21 165 11.4 0 11.7 11.4 09/11/2006 12:30:00 7.9 1 9.9 4.6 7.6 1.1 9.9 4.2 7.5 1 9.9 5.3 22 8 23 165 11.3 0 11.4 11.1 09/11/2006 12:40:00 7.8 1 9.5 4.9 7.4 1.1 9.1 4.6 7.6 1 9.5 5.3 19 7 360 165 11.3 0 11.7 11.1 09/11/2006 12:50:00 7.7 1.1 10.3 5.3 7.6 1.2 10.7 4.9 7.5 1.1 10.7 4.9 28 9 31 165 11.2 0 11.4 10.6 09/11/2006 13:00:00 8.1 1.2 10.7 4.9 7.9 1.3 10.7 3.8 7.9 1.2 11.1 5.3 29 9 33 165 11.6 0.1 11.9 10.9 09/11/2006 13:10:00 7.6 1.1 9.9 4.2 7.4 1.2 9.5 3.4 7.5 1 9.9 4.6 29 9 33 165 11.2 0.1 11.7 10.9 09/11/2006 13:20:00 7.9 1 10.3 5.3 7.6 1.1 10.3 4.2 7.6 1 10.3 4.9 24 8 23 165 11.2 0.1 11.7 10.6 09/11/2006 13:30:00 8.7 1.3 11.8 5.3 8.5 1.4 11.5 4.9 8.4 1.3 11.1 5.7 26 8 25 165 10.9 0.1 11.1 10.3 09/11/2006 13:40:00 8.9 0.9 10.7 5.7 8.7 1 10.3 5.3 8.6 1 11.1 6.1 25 7 34 165 11.1 0 11.7 10.6 09/11/2006 13:50:00 9 1 11.1 5.7 8.8 1 11.1 5.7 8.6 1 11.1 6.1 24 7 32 165 11.1 0 11.4 10.6 09/11/2006 14:00:00 9.3 0.9 11.5 6.1 9.1 1 11.8 5.3 8.7 1.1 11.1 5.3 24 6 22 165 10.8 0.1 11.1 10.6 09/11/2006 14:10:00 8.6 0.9 10.3 5.7 8.2 1 10.7 4.9 8.1 1 10.7 4.9 21 7 27 165 10.4 0.1 10.9 10.1 09/11/2006 14:20:00 8.5 1 10.3 5.3 8 1.1 10.3 4.9 8.1 1 10.3 5.3 19 6 14 165 10.2 0.2 10.6 9.8 09/11/2006 14:30:00 7.8 1 9.5 4.9 7.2 1.1 9.5 4.2 7.5 1 9.9 4.9 17 7 16 165 10.3 0.2 10.6 9.8 09/11/2006 14:40:00 8.1 0.8 10.7 5.3 7.6 1 10.3 4.6 7.8 1 11.1 4.9 19 6 15 165 10.3 0.2 10.9 9.8 09/11/2006 14:50:00 8.3 0.8 10.7 5.7 7.7 1 10.3 3.4 7.9 0.9 10.3 5.3 17 6 7 165 10.3 0.2 10.9 9.8 09/11/2006 15:00:00 8.4 0.8 9.9 6.1 7.6 1 9.5 3.8 8 0.8 10.3 5.7 17 7 10 165 10.5 0.2 10.9 9.8 09/11/2006 15:10:00 8.7 0.9 10.3 6.1 8 1.1 10.3 4.6 8.3 1 10.7 5.7 16 6 15 165 10.5 0.3 10.9 10.1 09/11/2006 15:20:00 8.4 1 10.7 5.7 7.7 1.2 10.3 4.2 8.1 1.1 11.1 4.9 15 7 18 165 10.5 0.3 10.9 9.8 09/11/2006 15:30:00 7.5 1 9.1 4.9 6.7 1.1 9.1 4.2 7.3 0.9 9.1 4.9 14 6 16 165 10.5 0.2 10.9 9.8 09/11/2006 15:40:00 6.9 0.6 8.8 5.3 6.1 1 8.4 3 6.7 0.8 8.8 4.9 14 6 19 165 10.5 0 10.9 10.1 09/11/2006 15:50:00 6.7 0.9 9.1 4.9 5.7 1.2 9.1 3 6.6 0.9 9.1 4.6 12 7 7 165 10.6 0.1 10.9 10.1 09/11/2006 16:00:00 7.7 1 10.3 4.9 5.5 1.2 8.8 3 7.7 1 9.9 4.9 6 8 6 165 10.7 0.1 10.9 10.1 09/11/2006 16:10:00 7 0.7 8.4 4.9 5.4 1.3 8 2.6 7 0.7 8.8 4.6 9 8 23 165 10.8 0.2 11.1 10.3 09/11/2006 16:20:00 6.9 0.8 8.8 4.6 5.7 1.2 8.4 2.6 6.6 0.8 8.8 4.6 12 10 1 165 10.9 0.1 11.1 10.3 09/11/2006 16:30:00 6.4 0.7 9.1 4.6 5.1 1.1 8.4 2.3 6.3 0.7 8.4 4.6 11 8 1 165 10.9 0.1 11.1 10.6 09/11/2006 16:40:00 7.3 0.6 9.1 5.7 5.7 1.1 8.4 3 7.3 0.6 8.8 5.7 10 8 21 165 10.7 0.2 11.1 10.3 09/11/2006 16:50:00 6.1 0.8 8 4.6 4.3 1.1 7.6 2.3 6.1 0.7 8.4 4.6 6 7 10 165 10.6 0.3 11.4 10.3 09/11/2006 17:00:00 7.3 0.6 8.8 5.3 5.2 1 8 3 7.2 0.7 8.4 4.9 9 6 4 165 10.6 0.3 10.9 10.3 09/11/2006 17:10:00 6.6 0.7 8.4 4.6 4.7 1.1 7.6 2.6 6.6 0.7 8.4 4.2 7 9 355 165 10.9 0.2 11.4 10.3 09/11/2006 17:20:00 6.9 0.9 9.1 4.9 5.6 1.3 8.8 2.6 6.9 0.9 9.1 4.9 13 6 12 165 10.8 0.2 11.1 10.3 09/11/2006 17:30:00 6.6 0.7 8.8 4.9 5.4 1.2 8.8 2.6 6.7 0.7 8.8 4.6 13 5 23 165 10.7 0.2 10.9 10.1 09/11/2006 17:40:00 6.5 0.8 8.4 4.6 4.7 1 7.2 2.3 6.5 0.8 8 4.2 9 6 12 165 10.7 0.1 10.9 10.1 09/11/2006 17:50:00 5.7 0.7 7.6 4.2 4.4 1.3 7.6 1.9 5.9 0.7 7.6 3.8 10 8 13 165 10.7 0.1 10.9 10.3 09/11/2006 18:00:00 6.1 0.7 7.6 4.6 4.4 1.3 7.2 1.9 6.2 0.7 7.6 3.8 9 7 7 165 10.7 0.1 10.9 10.1 09/11/2006 18:10:00 6 0.8 7.6 3.8 4.3 1.2 7.2 1.9 6 0.8 8 3.8 3 9 13 165 10.7 0 11.1 10.6 09/11/2006 18:20:00 5.7 0.7 7.6 4.6 3.9 1.3 7.2 1.9 5.9 0.7 8 4.6 6 7 16 165 10.7 0 10.9 10.6 09/11/2006 18:30:00 5.3 0.5 6.5 4.2 4.2 1 6.1 1.5 5.6 0.6 6.8 4.2 12 5 9 165 10.5 0 10.9 10.3 09/11/2006 18:40:00 4.7 0.4 5.7 3.4 3.2 0.7 4.9 1.5 4.7 0.4 6.1 3.4 7 5 14 165 10.4 0 10.9 9.8 09/11/2006 18:50:00 4.1 0.6 5.7 2.6 3.2 0.8 4.6 1.5 4.2 0.5 6.1 2.6 11 11 357 165 10.7 0.1 10.9 10.3 09/11/2006 19:00:00 3.6 0.3 4.6 2.6 2.1 0.7 4.2 0.7 3.8 0.4 4.9 2.6 2 7 18 165 10.6 0 10.9 10.3 09/11/2006 19:10:00 4.4 0.4 5.7 3.4 2.8 0.9 4.9 1.1 4.5 0.4 5.7 3.4 5 7 2 165 10.3 0 10.6 9.8 09/11/2006 19:20:00 4.2 0.5 5.3 3 2.5 0.7 4.2 1.1 4.3 0.5 5.3 3 359 7 5 165 10.3 0 10.6 9.8 09/11/2006 19:30:00 3.9 0.5 5.3 2.3 2.4 0.7 4.6 1.5 4.1 0.5 5.3 2.6 5 9 14 165 10.1 0.1 10.3 9.6 09/11/2006 19:40:00 4 0.3 5.3 3 3.2 0.8 4.9 1.5 4.3 0.3 4.9 3.4 13 6 21 165 10.1 0.2 10.3 9.6 09/11/2006 19:50:00 4.3 0.3 5.3 3.4 2.5 0.5 3.8 1.5 4.6 0.4 5.3 3 5 4 0 165 10.1 0.2 10.3 9.6 09/11/2006 20:00:00 4.5 0.3 5.7 3.8 3.1 0.8 4.9 1.5 4.7 0.3 5.3 4.2 9 7 2 165 10.2 0.1 10.6 9.8 09/11/2006 20:10:00 4.2 0.4 5.3 3.4 3.8 0.6 4.9 1.5 4.4 0.4 5.3 3.4 17 4 15 165 10.1 0.1 10.6 9.8 09/11/2006 20:20:00 4.2 0.3 4.9 3.8 2.5 0.6 4.6 1.1 4.5 0.3 5.3 3.8 6 4 6 165 10.1 0.2 10.3 9.6 09/11/2006 20:30:00 4.4 0.4 5.7 3.4 2.6 0.6 4.2 1.1 4.6 0.3 5.7 3.8 5 5 359 165 9.8 0.1 10.1 9.3 09/11/2006 20:40:00 4.7 0.4 5.7 3.8 2.2 0.4 3.8 1.5 4.9 0.3 5.7 4.2 2 2 6 165 9.6 0.2 10.1 9 09/11/2006 20:50:00 4.4 0.3 4.9 3.8 2.3 0.6 4.2 1.1 4.7 0.3 5.7 4.2 1 5 4 165 9.6 0 9.8 9.3 09/11/2006 21:00:00 4.1 0.3 4.9 3.4 2.3 0.7 4.9 1.1 4.4 0.2 4.9 3.8 2 6 347 165 9.6 0 9.6 9.3 09/11/2006 21:10:00 3.8 0.3 4.6 3 2.3 0.6 3.8 0.7 4.1 0.3 4.9 3.4 358 5 360 165 9.4 0 9.6 9 09/11/2006 21:20:00 3.5 0.3 4.2 2.6 2 0.6 3.8 1.1 3.7 0.2 4.2 3 358 4 357 165 9.4 0 9.6 9.3 09/11/2006 21:30:00 3.7 0.4 4.9 3 2.8 0.6 4.6 1.1 3.9 0.3 4.9 3 353 3 355 165 9.3 0 9.6 9 09/11/2006 21:40:00 4.4 0.3 5.3 3.8 3.5 0.8 5.3 1.5 4.6 0.3 5.3 3.8 352 5 349 165 9.3 0 9.6 9 09/11/2006 21:50:00 4.6 0.5 5.7 3 3.7 1 5.7 1.5 4.6 0.4 5.7 3.4 352 5 344 165 9.4 0 9.6 9 09/11/2006 22:00:00 4.6 0.4 5.7 3.4 3.6 1 5.3 1.5 4.6 0.4 5.7 3.4 352 5 351 165 9.4 0 9.8 9 09/11/2006 22:10:00 4.5 0.4 5.3 3.4 3.9 0.7 5.3 1.9 4.6 0.4 5.3 3.8 350 5 349 165 9.4 0 9.6 9.3 09/11/2006 22:20:00 4.2 0.4 5.7 3 3.2 0.8 4.9 1.1 4.3 0.5 5.3 3.4 352 6 355 165 9.4 0 9.6 9 09/11/2006 22:30:00 4 0.4 4.9 2.6 3.5 0.6 4.9 1.9 4 0.5 4.9 2.6 348 6 348 165 9.4 0.1 9.8 9 09/11/2006 22:40:00 3.2 0.5 4.2 2.3 2 0.7 4.2 0.4 3.4 0.4 4.2 2.3 354 6 1 165 9.6 0 9.8 9.3 09/11/2006 22:50:00 3.6 0.3 4.2 2.6 2.6 0.6 3.8 1.1 3.8 0.4 4.6 2.6 353 5 355 165 9.6 0 9.8 9.6 09/11/2006 23:00:00 3.4 0.4 4.6 2.3 2.8 0.6 4.2 1.1 3.6 0.4 4.6 2.6 348 5 348 165 9.6 0 9.8 9.6 09/11/2006 23:10:00 3.2 0.5 4.2 1.9 2.9 0.6 4.6 1.1 3.4 0.4 4.2 2.6 344 7 350 165 9.8 0 10.1 9.6 09/11/2006 23:20:00 3 0.5 4.6 1.9 2.5 0.7 4.2 0.7 3.3 0.5 4.6 2.3 347 9 355 165 9.8 0 10.1 9.6 09/11/2006 23:30:00 2.4 0.4 3.8 1.5 2 0.6 3.8 0.4 2.7 0.3 3.8 1.9 344 8 341 165 9.9 0 10.1 9.8 09/11/2006 23:40:00 2.4 0.4 3.4 1.5 1.7 0.6 3.4 0.4 2.6 0.3 3.4 1.9 348 7 344 165 9.9 0 10.1 9.6 09/11/2006 23:50:00 2.5 0.5 3.4 1.5 1.8 0.9 3.4 0.4 2.7 0.4 3.8 1.9 348 7 350 165 10 0 10.3 9.6 09/12/2006 00:00:00 1.9 0.6 3.4 0.4 1.7 0.6 3.4 0.4 2 0.5 3.4 1.1 324 11 347 165 9.8 0 10.3 9.6 09/12/2006 00:10:00 2.3 0.4 3 1.5 2.1 0.4 3 1.1 2.5 0.3 3.4 1.5 323 6 328 165 10.3 0 10.6 9.8 09/12/2006 00:20:00 2.8 0.4 3.8 1.9 2.7 0.5 3.8 1.5 3.1 0.4 4.2 2.3 328 8 320 165 10.5 0 10.9 10.3 09/12/2006 00:30:00 2.6 0.2 3 1.9 2.5 0.3 3.4 1.9 2.8 0.2 3.4 2.3 334 7 323 165 10.5 0 10.9 10.1 09/12/2006 00:40:00 2.6 0.3 3 1.9 2.5 0.3 3.4 1.9 2.8 0.2 3.4 2.3 327 7 344 165 10.6 0 10.9 10.3 09/12/2006 00:50:00 1.9 0.5 3.4 1.1 1.7 0.5 3 0.7 2.2 0.4 3.4 1.5 318 4 321 165 10.7 0 11.1 10.6 09/12/2006 01:00:00 0.8 0.5 1.9 0.4 0.6 0.4 1.9 0.4 1.1 0.5 2.3 0.4 310 5 309 165 11 0 11.4 10.6 09/12/2006 01:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0.1 0.7 0.4 305 0 165 165 11.1 0.1 11.4 10.9 09/12/2006 01:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0.1 0.7 0.4 305 0 165 165 11.3 0.1 11.4 10.9 09/12/2006 01:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.5 0.2 1.1 0.4 305 0 165 165 11.2 0.1 11.4 10.9 09/12/2006 01:40:00 0.8 0.3 1.5 0.4 0.4 0.1 1.1 0.4 1 0.4 1.9 0.4 353 22 351 165 10.9 0.1 11.4 10.6 09/12/2006 01:50:00 1.5 0.4 2.6 0.7 1.2 0.5 2.3 0.4 1.9 0.3 2.6 1.1 339 2 342 165 10.7 0.1 11.1 10.3 09/12/2006 02:00:00 2.2 0.3 2.6 1.5 1.9 0.3 2.6 0.7 2.4 0.2 3 1.9 345 3 342 165 10.6 0 10.9 10.1 09/12/2006 02:10:00 2.1 0.2 2.6 1.5 1.1 0.5 2.3 0.4 2.4 0.2 2.6 1.9 352 4 346 165 10.8 0 11.1 10.3 09/12/2006 02:20:00 1.5 0.3 2.3 0.7 1 0.4 1.9 0.4 1.8 0.3 2.6 1.1 327 8 340 165 10.9 0 11.1 10.6 09/12/2006 02:30:00 1.5 0.2 2.3 0.7 1.1 0.3 1.9 0.7 1.8 0.3 2.6 1.1 310 10 304 165 11.1 0.2 11.7 10.9 09/12/2006 02:40:00 1.6 0.4 2.3 0.7 1.4 0.5 2.3 0.4 1.5 0.3 2.3 0.7 303 5 301 165 11.3 0 11.7 11.1 09/12/2006 02:50:00 1.9 0.2 2.3 1.5 1.8 0.2 2.3 1.5 1.7 0.2 2.3 1.1 300 3 300 165 11.3 0 11.4 11.1 09/12/2006 03:00:00 1.4 0.5 2.3 0.7 1.3 0.6 2.3 0.4 1.6 0.3 2.6 0.7 293 8 299 165 11.3 0 11.7 11.1 09/12/2006 03:10:00 1.2 0.5 2.3 0.4 0.9 0.6 2.3 0.4 1.5 0.4 2.6 0.7 291 7 295 165 11.5 0 11.7 11.4 09/12/2006 03:20:00 0.9 0.4 1.9 0.4 0.6 0.3 1.5 0.4 1.3 0.3 2.3 0.4 298 3 299 165 11.6 0 11.7 11.4 09/12/2006 03:30:00 1 0.3 1.9 0.4 0.7 0.3 1.5 0.4 1.3 0.4 2.3 0.4 286 8 295 165 11.7 0 11.9 11.4 09/12/2006 03:40:00 0.4 0.2 1.1 0.4 0.4 0 0.7 0.4 0.7 0.4 1.9 0.4 303 13 311 165 11.8 0 11.9 11.7 09/12/2006 03:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0.2 1.1 0.4 297 0 165 165 11.7 0 11.9 11.4 09/12/2006 04:00:00 0.5 0.2 1.1 0.4 0.4 0 0.4 0.4 0.6 0.3 1.5 0.4 219 69 157 165 11.8 0 11.9 11.7 09/12/2006 04:10:00 0.4 0.1 0.7 0.4 0.4 0 0.4 0.4 0.5 0.3 1.1 0.4 158 0 158 165 11.7 0 11.9 11.7 09/12/2006 04:20:00 0.4 0.1 1.1 0.4 0.4 0 0.4 0.4 0.4 0.3 1.9 0.4 163 26 290 165 11.7 0 11.9 11.7 09/12/2006 04:30:00 2 0.5 3 0.7 1.9 0.6 3 0.4 2.3 0.5 3.4 0.7 284 6 284 165 11.7 0 12.2 11.4 09/12/2006 04:40:00 2.2 0.4 3.4 1.5 2.1 0.4 3 1.1 2.5 0.4 3.4 1.5 283 6 287 165 11.5 0 11.7 11.1 09/12/2006 04:50:00 0.8 0.4 1.9 0.4 0.6 0.4 1.5 0.4 1.3 0.4 2.3 0.7 272 10 282 165 11.9 0.1 12.5 11.4 09/12/2006 05:00:00 0.4 0.1 0.7 0.4 0.4 0 0.4 0.4 0.5 0.3 1.1 0.4 255 0 255 165 12.3 0 12.5 11.9 09/12/2006 05:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 255 0 165 165 12.1 0.1 12.5 11.7 09/12/2006 05:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0.2 1.1 0.4 255 0 165 165 11.3 0.3 11.9 10.6 09/12/2006 05:30:00 0.4 0.1 0.7 0.4 0.4 0 0.4 0.4 0.9 0.2 1.5 0.4 268 19 297 165 10.9 0 11.1 10.6 09/12/2006 05:40:00 0.4 0.2 1.1 0.4 0.4 0 0.4 0.4 0.8 0.3 1.5 0.4 297 0 297 165 11.5 0 11.7 10.9 09/12/2006 05:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 297 0 165 165 11.1 0 11.7 10.9 09/12/2006 06:00:00 0.4 0.1 1.1 0.4 0.4 0 0.4 0.4 0.4 0.2 1.1 0.4 297 0 297 165 10.9 0.2 11.7 10.6 09/12/2006 06:10:00 1.9 0.4 3 0.7 1.7 0.5 3 0.4 1.9 0.5 3 0.7 289 4 288 165 12 0 12.2 11.4 09/12/2006 06:20:00 2.2 0.4 3 1.1 2 0.4 3 1.1 1.9 0.4 2.6 0.7 295 7 299 165 12 0 12.2 11.7 09/12/2006 06:30:00 1.9 0.5 3.4 1.1 1.8 0.5 3 1.1 1.8 0.4 3 0.7 305 5 308 165 12 0 12.2 11.7 09/12/2006 06:40:00 2.6 0.5 3.8 1.5 2.6 0.5 3.8 1.5 2.3 0.5 4.6 1.1 298 4 293 165 11.9 0 12.2 11.7 09/12/2006 06:50:00 2.8 0.5 4.2 1.9 2.8 0.5 3.8 1.5 2.4 0.5 3.8 1.5 296 5 290 165 12.1 0 12.2 11.9 09/12/2006 07:00:00 2.2 0.6 3.8 0.7 2.2 0.6 3.8 0.4 2.8 0.5 3.8 1.5 285 7 282 165 12.3 0.1 12.7 11.9 09/12/2006 07:10:00 3.6 0.4 4.6 2.3 3.6 0.5 4.6 2.3 3.6 0.5 4.6 2.3 287 5 287 165 12.5 0 12.7 11.9 09/12/2006 07:20:00 3.8 0.5 5.3 2.6 3.7 0.5 4.9 2.3 3.2 0.5 4.6 1.9 293 3 291 165 12.5 0 12.7 12.2 09/12/2006 07:30:00 4.8 0.4 6.1 3.8 4.8 0.4 6.1 3.8 3.8 0.5 4.9 2.6 295 3 296 165 12.5 0 12.7 11.9 09/12/2006 07:40:00 4.4 0.6 5.7 3 4.4 0.6 5.7 3 3.7 0.8 5.7 2.3 292 3 289 165 12.6 0.2 13 11.9 09/12/2006 07:50:00 3.9 0.6 5.3 2.3 3.8 0.6 5.3 2.3 3.2 0.7 4.9 1.9 292 6 295 165 13 0.1 13.3 12.5 09/12/2006 08:00:00 2.9 0.5 4.2 1.9 2.9 0.5 4.2 1.5 3 0.6 4.6 1.5 288 6 284 165 13.1 0 13.3 12.7 09/12/2006 08:10:00 2.1 0.7 4.2 0.7 1.9 0.8 4.2 0.4 2.2 0.7 3.8 0.7 288 10 285 165 13.3 0.1 13.8 12.7 09/12/2006 08:20:00 1.1 0.5 2.3 0.4 1 0.6 2.3 0.4 1.8 0.4 2.6 0.7 273 6 280 165 13.8 0 13.8 13.5 09/12/2006 08:30:00 2.1 0.6 3.8 0.7 2.3 0.7 4.2 0.7 2.8 0.5 4.2 1.5 274 9 281 165 13.9 0.1 14.1 13.3 09/12/2006 08:40:00 3.1 0.6 4.6 1.9 3.3 0.6 5.3 1.9 3.5 0.6 5.3 1.9 280 11 291 165 13.9 0 14.1 13.8 09/12/2006 08:50:00 2.8 0.8 4.6 1.1 2.7 0.8 4.6 0.7 2.9 0.7 4.6 1.5 290 8 281 165 13.9 0 14.4 13.8 09/12/2006 09:00:00 0.9 0.6 3 0.4 0.8 0.6 3 0.4 1.3 0.7 3.8 0.4 264 11 279 165 14.4 0.4 15.2 13.8 09/12/2006 09:10:00 2 0.9 3.8 0.4 2.1 1 4.2 0.4 2.6 0.7 4.2 1.1 274 8 277 165 15.3 0 15.7 15.2 09/12/2006 09:20:00 2.5 0.7 4.2 0.4 3 0.6 4.6 1.1 3.1 0.6 4.6 1.5 270 7 285 165 15.2 0.1 15.7 14.9 09/12/2006 09:30:00 2.1 0.7 3.8 0.7 2.5 0.7 4.2 0.4 2.6 0.6 4.2 1.1 266 11 282 165 15.3 0 15.5 15.2 09/12/2006 09:40:00 2.3 0.6 4.2 0.7 3 0.7 4.9 1.5 3.1 0.6 4.6 1.5 260 8 258 165 15.2 0 15.5 15.2 09/12/2006 09:50:00 1.9 0.5 3.4 0.7 2 0.6 3.8 0.4 2.3 0.5 3.8 1.1 258 12 276 165 15.6 0.2 16.3 15.2 09/12/2006 10:00:00 1.8 0.4 3 0.7 1.9 0.5 3 0.7 2.2 0.4 3 0.7 272 10 285 165 16.1 0 16.8 16 09/12/2006 10:10:00 1.6 0.6 3.4 0.4 1.5 0.7 3.4 0.4 2 0.6 3.4 0.4 254 20 204 165 16.1 0 16.6 16 09/12/2006 10:20:00 2.3 0.7 4.2 0.4 1.9 0.8 4.2 0.4 2.4 0.7 4.6 0.7 223 18 237 165 16.1 0 16.6 15.7 09/12/2006 10:30:00 2.2 0.6 3.8 0.7 1.7 0.7 3.4 0.4 2.4 0.6 4.6 1.1 185 24 201 165 16 0 16.3 15.7 09/12/2006 10:40:00 2.2 0.6 3.8 0.4 1.7 0.7 3.4 0.4 2.4 0.6 3.8 1.1 173 15 166 165 16.2 0.1 16.6 15.7 09/12/2006 10:50:00 2 0.6 3.8 0.4 1.5 0.8 3.8 0.4 2.2 0.5 3.8 0.7 152 17 163 165 16.1 0 16.6 15.7 09/12/2006 11:00:00 2.6 0.6 3.8 1.1 2.2 0.7 4.2 0.4 2.8 0.5 4.2 1.1 162 13 168 165 15.9 0 16.3 15.2 09/12/2006 11:10:00 2.1 0.6 4.2 0.7 1.7 0.7 3.4 0.4 2.3 0.5 3.8 0.4 158 13 180 165 16.1 0.2 16.6 15.5 09/12/2006 11:20:00 2.1 0.6 3.8 0.7 1.8 0.7 3.8 0.4 2.5 0.5 3.8 1.5 161 11 165 165 16.6 0 16.8 16.3 09/12/2006 11:30:00 1.4 0.7 3 0.4 1.2 0.6 2.6 0.4 1.7 0.6 3 0.4 167 19 153 165 16.6 0 17.1 16.3 09/12/2006 11:40:00 1 0.7 2.6 0.4 1.2 0.7 3 0.4 1.1 0.8 3 0.4 146 72 156 165 16.8 0 17.1 16.6 09/12/2006 11:50:00 1.7 0.6 3 0.4 1.8 0.5 3 0.7 1.8 0.7 3.4 0.4 169 18 165 165 16.8 0 17.1 16.6 09/12/2006 12:00:00 1.8 0.6 3.4 0.4 1.8 0.7 3.8 0.4 2.1 0.6 3.4 0.4 167 14 173 165 16.8 0 17.1 16.6 09/12/2006 12:10:00 1.8 0.6 3 0.4 1.8 0.6 3.4 0.4 1.9 0.6 3.8 0.4 161 19 152 165 16.6 0.1 17.1 16.3 09/12/2006 12:20:00 1.2 0.7 3 0.4 1.3 0.7 3 0.4 1.8 0.8 4.2 0.4 160 21 165 165 16.3 0.2 16.8 16 09/12/2006 12:30:00 1.3 0.6 3 0.4 1.4 0.6 3 0.4 1.6 0.7 3 0.4 156 22 144 165 16.1 0.1 16.3 15.5 09/12/2006 12:40:00 1.5 0.9 3.4 0.4 1.6 0.9 3.8 0.4 1.9 0.8 3.8 0.4 161 11 156 165 16.2 0.1 16.6 16 09/12/2006 12:50:00 2 0.6 3.4 0.4 2.2 0.5 3.4 0.4 2.4 0.5 3.4 1.1 155 20 129 165 17 0.3 17.4 16.6 09/12/2006 13:00:00 1.5 0.8 3.8 0.4 1.6 0.8 3.8 0.4 1.9 0.6 3.8 0.4 157 17 153 165 17 0.2 17.4 16.8 09/12/2006 13:10:00 1.8 0.6 3.4 0.4 1.9 0.6 3.8 0.4 2.1 0.6 3.8 0.7 168 13 165 165 17.3 0.1 17.7 17.1 09/12/2006 13:20:00 2.3 1.1 4.6 0.4 2.4 1 4.6 0.4 2.5 1 4.6 0.4 156 13 145 165 17.3 0 17.4 16.8 09/12/2006 13:30:00 2.8 0.6 4.2 1.5 2.8 0.6 4.2 1.5 3 0.5 4.6 1.9 147 11 135 165 17 0.2 17.4 16.6 09/12/2006 13:40:00 3.4 0.6 4.6 1.5 3.4 0.6 4.9 1.1 3.4 0.5 4.6 1.9 149 11 143 165 16.8 0 17.1 16.6 09/12/2006 13:50:00 3 0.6 4.6 1.1 2.9 0.6 4.2 1.5 3.2 0.5 4.6 1.9 147 12 155 165 16.8 0 17.1 16.6 09/12/2006 14:00:00 2.6 0.5 3.8 1.1 2.6 0.6 3.8 1.1 2.6 0.5 3.8 1.1 145 12 140 165 17 0.2 17.4 16.3 09/12/2006 14:10:00 3 0.5 4.2 1.5 3 0.5 4.2 1.5 3.1 0.5 4.6 2.3 149 11 159 165 17 0.1 17.4 16.3 09/12/2006 14:20:00 2.7 0.5 4.2 1.5 2.7 0.6 4.2 1.1 2.9 0.6 4.6 1.5 145 14 142 165 17.2 0.1 17.7 16.6 09/12/2006 14:30:00 2.9 0.5 4.2 1.9 2.9 0.5 4.2 1.5 3.1 0.5 4.2 1.9 141 12 152 165 17.3 0.1 17.7 16.8 09/12/2006 14:40:00 3.2 0.6 4.9 1.9 3.2 0.6 4.9 1.9 3.2 0.6 5.7 1.9 136 13 160 165 17.5 0 17.7 16.8 09/12/2006 14:50:00 2.8 0.4 4.2 1.5 2.8 0.5 4.6 1.5 2.9 0.4 4.2 1.9 148 10 133 165 17.3 0.2 17.7 16.8 09/12/2006 15:00:00 3 0.5 4.2 1.9 3 0.5 4.2 1.9 3.1 0.5 4.2 2.3 148 9 147 165 17.1 0 17.4 16.6 09/12/2006 15:10:00 2.9 0.6 4.6 1.5 2.8 0.6 4.6 1.5 3 0.5 4.2 1.9 148 9 156 165 17.3 0 17.4 16.8 09/12/2006 15:20:00 2.7 0.5 3.8 1.9 2.7 0.5 4.2 1.9 2.9 0.5 4.2 1.9 147 9 151 165 17.1 0.2 17.4 16.8 09/12/2006 15:30:00 2.7 0.4 3.8 1.5 2.6 0.4 3.8 1.5 2.8 0.5 4.2 1.9 145 8 154 165 17 0.2 17.4 16.8 09/12/2006 15:40:00 2.9 0.4 4.2 1.9 2.8 0.4 3.8 1.9 2.9 0.4 4.2 1.5 148 9 140 165 17.1 0.2 17.4 16.8 09/12/2006 15:50:00 3 0.4 4.2 1.9 3 0.4 4.2 1.9 3.1 0.4 4.2 1.9 149 8 154 165 17.1 0 17.4 16.8 09/12/2006 16:00:00 2.6 0.3 3.8 1.9 2.5 0.3 3.8 1.9 2.7 0.3 3.8 2.3 146 6 145 165 17.1 0 17.4 16.8 09/12/2006 16:10:00 2.5 0.3 3.8 1.9 2.4 0.3 3.4 1.5 2.6 0.4 3.8 1.9 149 7 134 165 16.9 0 17.1 16.8 09/12/2006 16:20:00 2.6 0.3 3.4 1.9 2.5 0.4 3.4 1.9 2.7 0.3 3.4 1.9 145 6 148 165 17 0 17.1 16.8 09/12/2006 16:30:00 2.5 0.3 3.4 1.5 2.4 0.3 3 1.9 2.6 0.3 3.4 1.9 144 5 154 165 16.8 0 17.1 16.6 09/12/2006 16:40:00 2.3 0.2 2.6 1.9 2.2 0.2 2.6 1.9 2.3 0.2 3 1.5 142 4 142 165 16.5 0 16.8 16.3 09/12/2006 16:50:00 2.2 0.3 3 1.5 2.1 0.3 2.6 1.1 2.1 0.2 2.6 1.5 152 8 163 165 16.7 0.1 16.8 16.3 09/12/2006 17:00:00 2.3 0.3 3 1.5 2.1 0.3 2.6 1.5 2.2 0.3 3 1.5 162 10 162 165 16.8 0 17.1 16.6 09/12/2006 17:10:00 2.2 0.2 2.6 1.5 2 0.2 2.6 1.1 2.2 0.3 2.6 1.5 163 3 164 165 16.7 0 16.8 16.6 09/12/2006 17:20:00 2.2 0.2 2.6 1.9 1.9 0.2 2.3 1.5 2.1 0.2 2.6 1.5 165 8 165 165 16.6 0 16.8 16.6 09/12/2006 17:30:00 2.1 0.2 2.6 1.9 1.8 0.2 2.3 1.5 2 0.2 2.6 1.5 169 2 169 165 16.4 0 16.8 16.3 09/12/2006 17:40:00 2 0.2 2.3 1.5 1.7 0.2 2.3 1.1 2 0.2 2.3 1.5 175 2 173 165 16.4 0 16.8 16.3 09/12/2006 17:50:00 2 0.3 2.6 1.5 1.7 0.4 2.3 1.1 1.9 0.4 2.6 0.7 173 3 176 165 16.4 0 16.8 16.3 09/12/2006 18:00:00 1.8 0.4 2.6 1.1 1.5 0.4 2.3 0.7 1.6 0.4 2.3 1.1 167 1 166 165 16.1 0 16.6 16 09/12/2006 18:10:00 1.8 0.2 2.3 1.1 1.6 0.2 2.3 1.1 1.8 0.3 2.3 1.1 167 2 165 165 16.1 0 16.3 15.7 09/12/2006 18:20:00 1.8 0.2 2.3 1.5 1.7 0.2 2.3 1.1 1.7 0.2 2.3 1.1 175 1 176 165 16 0 16.3 15.7 09/12/2006 18:30:00 1.7 0.2 2.3 1.1 1.5 0.3 2.3 1.1 1.7 0.2 2.3 1.1 175 1 176 165 15.9 0 16.3 15.7 09/12/2006 18:40:00 1.4 0.2 1.9 1.1 1.3 0.2 1.5 0.7 1.4 0.2 1.9 1.1 168 3 173 165 15.7 0 16 15.7 09/12/2006 18:50:00 1.5 0.2 2.3 1.1 1.3 0.2 1.9 0.7 1.3 0.2 1.9 0.7 170 1 173 165 15.7 0 16 15.7 09/12/2006 19:00:00 2.1 0.2 2.6 1.9 1.9 0.2 2.3 1.5 1.9 0.2 2.3 1.5 176 2 178 165 15.5 0 16 15.5 09/12/2006 19:10:00 1.6 0.3 2.3 1.1 1.5 0.3 1.9 1.1 1.5 0.3 2.3 1.1 178 3 178 165 15.2 0.1 15.7 14.9 09/12/2006 19:20:00 1.4 0.2 1.9 0.7 1.3 0.2 1.9 0.7 1.4 0.2 1.9 0.7 188 2 187 165 14.8 0.1 15.2 14.1 09/12/2006 19:30:00 1.1 0.2 1.5 0.7 1 0.2 1.5 0.7 1.1 0.1 1.5 0.7 189 1 190 165 14.8 0 14.9 14.4 09/12/2006 19:40:00 1.1 0.2 1.9 0.7 1 0.2 1.5 0.7 1.3 0.2 1.5 0.7 189 2 189 165 14.8 0 14.9 14.6 09/12/2006 19:50:00 1.7 0.2 2.3 1.1 1.6 0.2 1.9 1.1 1.6 0.2 1.9 1.1 190 2 191 165 14.9 0 14.9 14.9 09/12/2006 20:00:00 1.4 0.2 1.9 0.7 1.3 0.2 1.9 0.7 1.4 0.2 1.9 0.7 197 1 197 165 14.7 0.1 14.9 14.6 09/12/2006 20:10:00 1.1 0.2 1.5 0.7 1.1 0.2 1.5 0.7 1.3 0.2 1.5 1.1 197 1 198 165 14.8 0 14.9 14.6 09/12/2006 20:20:00 1.1 0.2 1.5 0.7 1.1 0.2 1.5 0.7 1.4 0.2 1.9 0.7 202 7 197 165 14.7 0 14.9 14.6 09/12/2006 20:30:00 1.2 0.2 1.9 0.7 1.2 0.2 1.9 0.7 1.5 0.2 1.9 1.1 213 1 213 165 14.8 0 14.9 14.6 09/12/2006 20:40:00 0.8 0.2 1.1 0.4 0.8 0.2 1.1 0.4 1.2 0.2 1.5 0.7 213 1 210 165 14.8 0 15.2 14.6 09/12/2006 20:50:00 0.8 0.3 1.5 0.4 0.7 0.3 1.1 0.4 1.1 0.3 1.5 0.4 213 1 213 165 14.8 0 15.2 14.6 09/12/2006 21:00:00 0.4 0.1 0.7 0.4 0.4 0 0.4 0.4 0.4 0.2 1.1 0.4 212 2 213 165 15.2 0 15.5 14.6 09/12/2006 21:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 212 2 165 165 15.2 0 15.7 14.9 09/12/2006 21:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 213 1 165 165 15.1 0 15.5 14.9 09/12/2006 21:30:00 0.7 0.3 1.1 0.4 0.6 0.3 1.1 0.4 0.4 0.2 1.1 0.4 227 16 213 165 15.2 0 15.5 14.9 09/12/2006 21:40:00 1.6 0.3 2.3 0.7 1.6 0.3 2.3 0.7 1.4 0.4 2.3 0.4 280 13 288 165 14.9 0.2 15.5 14.1 09/12/2006 21:50:00 1.2 0.2 1.9 0.7 1.2 0.3 1.9 0.7 1.1 0.3 1.9 0.4 279 1 283 165 14.8 0 15.2 14.1 09/12/2006 22:00:00 0.9 0.2 1.5 0.4 0.9 0.2 1.5 0.4 0.9 0.3 1.5 0.4 279 0 279 165 14.9 0 15.2 14.6 09/12/2006 22:10:00 0.6 0.3 1.1 0.4 0.5 0.2 1.1 0.4 0.6 0.3 1.5 0.4 279 0 279 165 15 0.1 15.2 14.6 09/12/2006 22:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 279 0 165 165 14.8 0.2 15.2 14.4 09/12/2006 22:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 279 0 165 165 14.9 0 15.2 14.1 09/12/2006 22:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 279 0 165 165 14.8 0 15.2 14.6 09/12/2006 22:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 279 0 165 165 14.2 0.2 14.6 14.1 09/12/2006 23:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 279 0 165 165 14.1 0 14.4 14.1 09/12/2006 23:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 279 0 165 165 14.1 0 14.4 13.8 09/12/2006 23:20:00 0.5 0.2 1.1 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 237 28 217 165 14.2 0 14.4 13.8 09/12/2006 23:30:00 0.4 0.1 1.1 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 213 0 213 165 14.2 0 14.4 14.1 09/12/2006 23:40:00 0.7 0.2 1.1 0.4 0.4 0 0.4 0.4 0.4 0.1 0.7 0.4 213 0 213 165 14.7 0.2 15.2 14.1 09/12/2006 23:50:00 0.4 0.2 1.1 0.4 0.4 0 0.7 0.4 0.4 0.1 0.7 0.4 216 9 214 165 15 0 15.2 14.9 09/13/2006 00:00:00 0.8 0.3 1.5 0.4 0.7 0.3 1.5 0.4 0.8 0.4 1.9 0.4 243 5 239 165 14.9 0 15.2 14.6 09/13/2006 00:10:00 0.6 0.2 1.1 0.4 0.4 0.1 1.1 0.4 0.9 0.2 1.1 0.4 254 9 259 165 15.2 0 15.2 15.2 09/13/2006 00:20:00 0.4 0.2 1.1 0.4 0.4 0 0.4 0.4 0.4 0.2 1.1 0.4 250 14 259 165 15.1 0 15.2 14.9 09/13/2006 00:30:00 0.4 0 0.4 0.4 0.4 0.1 1.1 0.4 0.6 0.3 1.5 0.4 218 7 165 165 14.6 0.1 15.2 14.4 09/13/2006 00:40:00 0.4 0 0.4 0.4 0.5 0.3 1.5 0.4 0.9 0.4 1.5 0.4 213 0 165 165 14.8 0 15.2 14.6 09/13/2006 00:50:00 0.6 0.3 1.1 0.4 0.9 0.2 1.1 0.7 1.2 0.2 1.5 0.7 220 8 231 165 15 0.1 15.2 14.6 09/13/2006 01:00:00 1.3 0.3 1.9 0.4 1.2 0.3 1.9 0.4 1.4 0.3 1.9 0.7 236 4 231 165 15.2 0 15.5 15.2 09/13/2006 01:10:00 0.5 0.2 1.1 0.4 0.4 0 0.7 0.4 0.5 0.3 1.1 0.4 258 15 271 165 14.9 0.3 15.5 14.4 09/13/2006 01:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0.1 0.7 0.4 271 0 165 165 14.3 0 14.6 14.1 09/13/2006 01:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 270 0 165 165 14.7 0 14.9 14.6 09/13/2006 01:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 270 0 165 165 14.5 0 14.9 14.4 09/13/2006 01:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 242 24 165 165 14.1 0.1 14.6 13.8 09/13/2006 02:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 218 0 165 165 13.7 0 13.8 13.5 09/13/2006 02:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 218 0 165 165 13.4 0 13.8 13 09/13/2006 02:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 218 0 165 165 13 0.1 13.3 12.7 09/13/2006 02:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 218 0 165 165 13.2 0.2 13.5 12.7 09/13/2006 02:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 218 0 165 165 13.5 0 13.8 13.3 09/13/2006 02:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 218 0 165 165 13.2 0.1 13.5 12.7 09/13/2006 03:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.7 0.4 218 0 165 165 12.7 0 13 12.5 09/13/2006 03:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 218 0 165 165 13.2 0.2 13.5 12.2 09/13/2006 03:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 218 0 165 165 13.5 0 13.8 13.3 09/13/2006 03:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 218 0 165 165 13.5 0 13.8 13.3 09/13/2006 03:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 218 0 165 165 13.1 0.1 13.3 13 09/13/2006 03:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 218 0 165 165 13.4 0.2 13.8 12.7 09/13/2006 04:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 218 0 165 165 13.9 0 14.1 13.5 09/13/2006 04:10:00 0.4 0.1 1.1 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 146 43 64 165 13.3 0.1 13.8 13 09/13/2006 04:20:00 0.4 0.2 1.1 0.4 0.4 0.1 1.1 0.4 0.4 0 0.4 0.4 92 19 105 165 13.3 0 13.5 12.7 09/13/2006 04:30:00 0.7 0.3 1.5 0.4 0.4 0 0.4 0.4 1.1 0.3 1.5 0.4 105 0 105 165 13.3 0.2 13.5 12.7 09/13/2006 04:40:00 1.3 0.2 1.9 1.1 1.3 0.4 1.9 0.4 1.7 0.2 2.3 1.1 105 0 105 165 13.2 0.1 13.5 12.7 09/13/2006 04:50:00 1.4 0.2 1.9 1.1 1.5 0.2 1.9 1.1 1.7 0.2 2.3 1.5 114 2 106 165 13.1 0 13.5 12.7 09/13/2006 05:00:00 1.2 0.2 1.9 0.7 1.2 0.2 1.9 0.7 1.6 0.2 1.9 1.1 118 1 115 165 13.1 0.1 13.5 12.7 09/13/2006 05:10:00 1.6 0.2 1.9 1.1 1.6 0.2 1.9 1.1 2 0.2 2.3 1.5 116 4 119 165 12.8 0.2 13.3 12.5 09/13/2006 05:20:00 1 0.2 1.5 0.4 1 0.2 1.5 0.4 1.4 0.2 1.9 1.1 115 6 107 165 13 0.2 13.3 12.5 09/13/2006 05:30:00 0.9 0.3 1.5 0.4 0.6 0.4 1.9 0.4 1.4 0.2 1.9 0.7 117 0 117 165 12.9 0.1 13.3 12.5 09/13/2006 05:40:00 1.4 0.2 1.9 1.1 1.4 0.2 1.9 1.1 1.7 0.2 2.3 1.1 117 0 117 165 12.4 0.2 13 11.9 09/13/2006 05:50:00 1.6 0.2 2.3 1.1 1.5 0.2 1.9 1.1 1.9 0.2 2.3 1.5 130 10 142 165 12.4 0.3 13 11.9 09/13/2006 06:00:00 1.6 0.3 2.3 1.1 1.5 0.3 2.3 1.1 1.8 0.2 2.3 1.5 144 2 140 165 12.5 0.2 13 11.9 09/13/2006 06:10:00 1.6 0.2 1.9 1.1 1.5 0.2 1.9 1.1 1.9 0.2 2.3 1.5 146 4 144 165 12.3 0.3 12.7 11.9 09/13/2006 06:20:00 1.4 0.2 1.9 0.7 1.3 0.2 1.9 0.7 1.8 0.2 2.3 1.5 139 5 137 165 12.5 0.2 12.7 11.9 09/13/2006 06:30:00 1.4 0.3 2.3 0.7 1.3 0.3 1.9 0.7 1.8 0.2 2.3 1.5 132 5 130 165 12.4 0.2 12.7 11.9 09/13/2006 06:40:00 1.9 0.2 2.3 1.1 1.9 0.2 2.3 1.5 2 0.2 2.3 1.5 136 4 130 165 12.4 0.1 12.7 11.9 09/13/2006 06:50:00 2.5 0.4 3.4 1.9 2.4 0.4 3 1.9 2.5 0.4 3.8 1.9 150 17 171 165 12.5 0.2 12.7 12.2 09/13/2006 07:00:00 3.3 0.4 3.8 2.3 3.1 0.4 3.8 2.3 3.2 0.2 3.8 2.6 165 2 164 165 12.7 0.2 13 12.2 09/13/2006 07:10:00 3.2 0.2 3.8 2.6 2.9 0.2 3.4 2.6 3 0.3 3.8 2.3 164 4 165 165 12.7 0.1 13 12.5 09/13/2006 07:20:00 3.8 0.4 4.6 3 3.5 0.4 4.2 2.6 3.6 0.2 4.2 3 168 3 170 165 12.9 0.1 13.3 12.5 09/13/2006 07:30:00 3.6 0.3 4.2 2.3 3.3 0.3 3.8 2.3 3.1 0.3 3.8 2.3 167 3 170 165 13.4 0.2 14.1 13 09/13/2006 07:40:00 3 0.6 4.2 1.5 2.8 0.6 3.8 1.5 2.5 0.5 3.4 1.5 165 10 165 165 14.1 0.1 14.4 13.8 09/13/2006 07:50:00 2.9 0.5 3.8 1.9 2.7 0.5 3.4 1.5 2.5 0.4 3.4 1.5 165 7 164 165 13.6 0.1 14.1 13.3 09/13/2006 08:00:00 2.8 0.4 3.4 1.9 2.6 0.4 3.4 1.1 2.6 0.4 3.4 1.9 161 4 162 165 14.2 0.1 14.4 13.5 09/13/2006 08:10:00 2.8 0.3 3.4 1.9 2.6 0.3 3 1.5 2.6 0.4 3.4 1.9 158 4 162 165 14.1 0 14.4 13.5 09/13/2006 08:20:00 2.6 0.4 3.4 1.9 2.4 0.4 3 1.5 2.6 0.3 3.4 1.9 156 5 161 165 14 0 14.4 13.8 09/13/2006 08:30:00 2.9 0.3 3.8 2.3 2.8 0.3 3.8 1.9 3 0.3 3.8 2.3 152 4 154 165 13.7 0.1 14.1 13.3 09/13/2006 08:40:00 3.6 0.4 4.6 2.6 3.5 0.4 4.2 2.6 3.4 0.3 4.2 2.6 153 3 156 165 13.6 0 13.8 13.3 09/13/2006 08:50:00 3.9 0.4 4.9 3 3.7 0.4 4.9 2.6 3.7 0.3 4.6 3 156 5 157 165 13.7 0.2 14.1 13.3 09/13/2006 09:00:00 3.6 0.4 4.6 2.6 3.4 0.4 4.6 2.6 3.5 0.3 4.6 2.6 157 8 165 165 13.7 0.2 14.1 13.3 09/13/2006 09:10:00 4 0.5 4.9 2.6 3.8 0.4 4.9 2.6 3.9 0.4 4.9 3 159 5 163 165 13.8 0.3 14.4 13.3 09/13/2006 09:20:00 4.3 0.4 5.3 3 4.1 0.4 4.9 3 4.1 0.3 4.9 3.4 158 4 162 165 14.3 0 14.6 13.8 09/13/2006 09:30:00 4.5 0.4 5.7 3.8 4.3 0.4 5.3 3.4 4.4 0.4 5.7 3.4 162 9 162 165 14.3 0.2 14.9 13.8 09/13/2006 09:40:00 4.7 0.5 5.7 3.8 4.4 0.5 5.7 3.4 4.7 0.6 5.7 3 162 9 165 165 14.3 0 14.6 14.1 09/13/2006 09:50:00 5 0.7 6.1 3 4.7 0.6 5.7 3 4.8 0.6 6.1 3.4 165 10 166 165 14.2 0.1 14.6 13.8 09/13/2006 10:00:00 4.9 0.6 6.1 3.4 4.7 0.5 5.7 3.4 4.8 0.5 6.1 3.4 163 9 163 165 14.2 0 14.6 14.1 09/13/2006 10:10:00 4.2 0.5 5.3 2.6 4 0.5 5.3 2.3 4.3 0.5 5.3 2.6 159 14 162 165 14.4 0 14.9 14.1 09/13/2006 10:20:00 4.6 0.5 6.1 3 4.3 0.5 5.7 2.3 4.6 0.4 5.7 3.4 159 6 154 165 13.9 0.3 14.6 13.3 09/13/2006 10:30:00 4.6 0.7 6.5 3 4.4 0.7 6.1 2.6 4.5 0.7 6.1 3 157 8 159 165 13.5 0 13.8 13.3 09/13/2006 10:40:00 4.2 0.7 6.5 2.3 4 0.7 6.1 2.3 4.2 0.7 6.1 2.6 151 8 155 165 13.5 0 14.1 13.3 09/13/2006 10:50:00 4.8 0.6 6.1 3.4 4.6 0.6 5.7 3 4.7 0.6 6.1 3 151 7 154 165 13.8 0.1 14.4 13.5 09/13/2006 11:00:00 4.8 0.5 6.1 3 4.7 0.5 6.1 3 4.8 0.4 6.1 3.4 148 7 129 165 14.1 0 14.6 13.8 09/13/2006 11:10:00 5 0.5 6.1 3.4 4.9 0.5 6.5 3.4 5.1 0.5 6.1 3.4 149 7 153 165 14.3 0.1 14.6 13.8 09/13/2006 11:20:00 4.9 0.5 6.5 3.4 4.8 0.5 6.5 3.8 4.9 0.5 6.5 3 151 6 148 165 13.9 0.1 14.4 13.3 09/13/2006 11:30:00 5.3 0.5 6.5 3.8 5.2 0.5 6.8 3.4 5.2 0.5 6.8 3.8 143 7 155 165 13.3 0.1 13.8 13 09/13/2006 11:40:00 5.5 0.6 7.2 3.8 5.6 0.6 6.8 3.8 5.7 0.6 7.6 3.8 144 7 160 165 13.3 0.2 14.1 13 09/13/2006 11:50:00 6.3 0.6 7.6 4.2 6.5 0.6 7.6 4.2 6.5 0.6 8 4.6 144 6 151 165 13.1 0.2 13.8 12.7 09/13/2006 12:00:00 5.7 0.6 7.2 4.2 5.9 0.6 7.2 4.2 5.9 0.6 7.2 4.2 138 7 124 165 12.7 0 13.3 12.5 09/13/2006 12:10:00 6.7 0.7 8.8 4.9 6.8 0.6 8.8 4.9 6.9 0.7 8.8 5.3 145 7 156 165 13.4 0 13.5 13 09/13/2006 12:20:00 7.7 0.5 8.8 5.3 7.6 0.5 8.8 5.3 7.8 0.5 9.1 6.1 149 4 158 165 13.3 0 13.8 13 09/13/2006 12:30:00 8.1 0.5 8.8 6.5 8 0.5 8.8 6.8 8.2 0.5 9.1 6.5 150 4 145 165 13.5 0 13.8 13 09/13/2006 12:40:00 7.3 0.5 8.4 5.3 7.3 0.5 8.4 5.3 7.3 0.6 8.8 5.7 148 4 150 165 12.9 0.1 13.3 12.7 09/13/2006 12:50:00 6.9 0.4 8 5.7 6.9 0.5 8 5.7 6.9 0.6 8 5.3 146 3 145 165 12.9 0.1 13.5 12.7 09/13/2006 13:00:00 7.1 0.4 8 6.1 7.1 0.4 8.4 6.1 7.2 0.4 8.4 6.1 147 4 144 165 13.1 0.2 13.8 12.5 09/13/2006 13:10:00 7.9 0.5 9.1 6.5 7.9 0.5 8.8 6.5 8 0.5 8.8 6.1 146 4 139 165 13.3 0.1 13.5 13 09/13/2006 13:20:00 7.6 0.6 9.1 6.1 7.6 0.6 9.5 6.1 7.6 0.7 9.1 5.7 146 4 149 165 13.7 0.2 14.4 13.3 09/13/2006 13:30:00 7.9 0.4 8.8 6.5 8 0.4 9.1 6.5 7.9 0.5 9.5 6.1 145 4 142 165 13.7 0.2 14.6 13.3 09/13/2006 13:40:00 7.9 0.5 9.5 6.5 8 0.4 9.5 6.5 7.9 0.5 9.5 6.1 146 4 146 165 12.9 0.2 13.8 12.5 09/13/2006 13:50:00 8.3 0.6 9.9 6.8 8.3 0.6 9.5 6.8 8.2 0.7 9.9 6.5 149 4 146 165 12.4 0.2 12.7 11.9 09/13/2006 14:00:00 8.1 0.5 9.1 6.5 8.1 0.5 9.1 6.5 7.9 0.6 9.1 6.1 149 4 150 165 11.7 0 11.9 11.7 09/13/2006 14:10:00 7.9 0.5 9.1 6.5 7.9 0.5 9.1 6.5 7.7 0.6 9.1 5.7 148 4 148 165 11.9 0.1 12.2 11.7 09/13/2006 14:20:00 7.9 0.5 8.8 6.5 8 0.5 9.1 6.5 7.8 0.5 9.1 6.1 147 4 151 165 11.1 0.1 11.7 10.9 09/13/2006 14:30:00 8.6 0.6 9.9 7.2 8.7 0.6 10.3 7.2 8.5 0.7 9.9 6.8 149 4 151 165 11.3 0.1 11.7 11.1 09/13/2006 14:40:00 8.1 0.6 9.5 6.8 8.2 0.6 9.5 6.8 8.2 0.6 9.9 6.5 150 4 152 165 11.5 0 11.7 11.1 09/13/2006 14:50:00 7.9 0.4 9.1 6.8 8 0.4 8.8 6.8 8 0.5 9.1 6.5 148 4 148 165 11.7 0 11.9 11.4 09/13/2006 15:00:00 8.1 0.7 10.3 6.1 8.2 0.7 10.3 6.5 8.2 0.7 9.9 6.8 145 4 150 165 11.1 0.1 11.7 10.9 09/13/2006 15:10:00 8.7 0.6 9.9 7.2 8.7 0.6 9.9 7.2 8.7 0.6 9.9 7.2 145 5 143 165 10.7 0 10.9 10.3 09/13/2006 15:20:00 8.9 0.4 9.9 7.6 9 0.4 9.9 7.6 8.8 0.5 9.9 6.8 145 4 148 165 10.5 0 10.9 10.3 09/13/2006 15:30:00 8.3 0.6 9.5 6.5 8.4 0.6 9.5 6.5 8.2 0.6 9.9 6.1 140 6 147 165 10.3 0.1 10.6 10.3 09/13/2006 15:40:00 8.9 0.6 10.7 7.2 9 0.7 11.1 7.6 8.8 0.7 11.1 7.2 141 6 142 165 10.2 0 10.3 10.1 09/13/2006 15:50:00 9.9 0.7 11.5 8 10 0.6 11.5 8.4 9.7 0.8 11.5 6.1 145 4 148 165 10.2 0 10.3 10.1 09/13/2006 16:00:00 9.9 0.5 11.1 8 10 0.5 11.1 8.4 9.9 0.6 11.5 7.2 145 3 141 165 10.1 0.1 10.3 9.6 09/13/2006 16:10:00 10.3 0.5 11.5 8.8 10.4 0.5 11.5 8.8 10.2 0.6 11.5 8.4 147 3 150 165 9.9 0.1 10.3 9.6 09/13/2006 16:20:00 10.6 0.7 12.2 8.8 10.7 0.7 12.2 8.8 10.5 0.7 12.6 8 148 4 145 165 10 0.1 10.3 9.3 09/13/2006 16:30:00 11.2 0.6 12.6 9.5 11.2 0.5 12.6 9.9 11.1 0.6 12.6 9.5 150 3 148 165 10.1 0 10.3 9.8 09/13/2006 16:40:00 11.1 0.6 12.6 9.9 11.1 0.6 12.6 9.5 11 0.6 12.2 9.1 150 3 151 165 10 0 10.3 9.8 09/13/2006 16:50:00 10.6 0.7 13 9.1 10.7 0.7 12.6 9.1 10.5 0.8 12.6 7.6 147 4 151 165 10 0 10.3 9.6 09/13/2006 17:00:00 10.8 0.6 12.2 9.1 10.8 0.6 12.2 9.1 10.7 0.7 12.6 9.1 149 3 149 165 10 0 10.1 9.6 09/13/2006 17:10:00 10.6 0.5 11.8 9.1 10.6 0.5 11.8 9.1 10.4 0.6 11.8 8.4 148 3 150 165 10 0 10.3 9.6 09/13/2006 17:20:00 9.9 0.5 11.1 8.8 9.9 0.5 11.1 8.4 9.7 0.5 11.1 8.4 147 3 145 165 10 0 10.3 9.6 09/13/2006 17:30:00 9.9 0.5 11.5 8.4 10 0.5 11.5 8.4 9.9 0.5 11.5 8.4 146 3 144 165 10 0 10.3 9.6 09/13/2006 17:40:00 10.5 0.5 11.8 8.8 10.6 0.5 11.8 8.8 10.4 0.6 11.8 8 146 3 148 165 10 0 10.3 9.8 09/13/2006 17:50:00 11 0.5 12.2 9.5 11 0.5 12.2 9.5 10.9 0.5 12.2 9.1 147 3 147 165 10.1 0 10.3 9.8 09/13/2006 18:00:00 10.9 0.4 12.2 9.5 10.9 0.4 12.2 9.9 10.7 0.5 12.2 9.5 144 4 151 165 10.1 0 10.3 9.8 09/13/2006 18:10:00 10.5 0.6 11.8 8.8 10.5 0.6 12.2 8.8 10.2 0.7 11.8 8.4 146 4 151 165 10.1 0 10.3 9.8 09/13/2006 18:20:00 10.9 0.6 12.2 9.1 10.9 0.7 12.2 9.1 10.6 0.7 12.2 8.8 145 3 145 165 10.1 0 10.3 10.1 09/13/2006 18:30:00 11.2 0.6 12.6 9.1 11.3 0.6 12.6 9.5 11.1 0.6 12.2 9.1 145 3 146 165 10.2 0 10.3 10.1 09/13/2006 18:40:00 10.8 0.5 12.2 9.1 10.9 0.5 12.2 9.1 10.8 0.5 12.2 9.1 146 3 145 165 10.1 0 10.6 10.1 09/13/2006 18:50:00 10.2 0.5 11.5 8.8 10.3 0.5 11.5 8.8 10.1 0.6 11.5 8.4 146 3 139 165 10.1 0 10.3 9.8 09/13/2006 19:00:00 10.9 0.6 12.6 9.1 10.9 0.7 13 9.1 10.9 0.6 12.6 9.5 145 4 149 165 10.1 0 10.3 9.8 09/13/2006 19:10:00 10.6 0.6 12.6 8.4 10.6 0.6 12.6 8.4 10.5 0.6 12.2 8.4 146 4 145 165 10.1 0 10.3 9.8 09/13/2006 19:20:00 10.6 0.6 12.2 9.1 10.6 0.6 12.2 9.1 10.6 0.7 12.2 8.4 147 3 147 165 10.2 0 10.6 9.8 09/13/2006 19:30:00 10.2 0.5 11.5 8.4 10.2 0.5 11.5 8.8 10.2 0.6 11.5 8 148 4 152 165 10.3 0 10.6 9.8 09/13/2006 19:40:00 10.6 0.6 12.2 8.8 10.6 0.6 12.2 9.1 10.4 0.6 12.2 8.8 146 3 144 165 10.3 0 10.9 9.8 09/13/2006 19:50:00 11.3 0.7 13 9.5 11.3 0.7 13 9.5 11.3 0.7 13.3 9.5 148 4 144 165 10.3 0 10.6 9.8 09/13/2006 20:00:00 10.8 0.6 12.2 9.1 10.8 0.6 11.8 9.1 10.8 0.6 12.2 8.8 148 4 151 165 10.3 0 10.6 9.8 09/13/2006 20:10:00 11.1 0.8 13 9.1 11.1 0.7 13.3 9.1 10.9 0.8 13 9.1 145 4 151 165 10.3 0 10.6 9.8 09/13/2006 20:20:00 10.8 1.2 14.5 8.4 10.8 1.2 14.1 8.4 10.7 1.2 13.3 8.4 149 5 148 165 10.3 0 10.6 9.8 09/13/2006 20:30:00 10 0.9 12.6 7.6 10 0.9 12.6 8 9.9 0.9 12.2 7.2 142 7 150 165 10.3 0 10.9 9.8 09/13/2006 20:40:00 11 0.9 13 8.4 11 0.9 13 8.4 10.8 1 12.6 7.6 145 7 139 165 10.3 0 10.6 10.3 09/13/2006 20:50:00 11 1 13.7 8.4 11 1 13.7 8.8 10.6 1 13 8 140 7 141 165 10.3 0 10.6 10.3 09/13/2006 21:00:00 10.9 1 14.1 8 10.9 1 13.7 8 10.5 1.1 13 7.6 142 7 133 165 10.3 0 10.6 10.3 09/13/2006 21:10:00 11.9 0.8 14.1 9.9 11.9 0.8 13.7 9.9 11.8 0.9 14.1 8.8 147 6 143 165 10.3 0 10.6 10.3 09/13/2006 21:20:00 11.4 1.2 15.3 9.1 11.5 1.1 14.9 9.1 11.4 1.2 14.9 8.8 147 5 138 165 10.3 0 10.9 10.3 09/13/2006 21:30:00 10.9 1 13.3 8.8 10.9 1 13.7 8.4 10.6 1 13.3 8 147 5 139 165 10.3 0 10.6 10.3 09/13/2006 21:40:00 11.3 0.9 14.1 9.1 11.3 0.9 14.1 9.1 11.1 1 14.1 8.4 142 5 145 165 10.3 0 10.6 10.3 09/13/2006 21:50:00 10.4 1.2 13.7 6.8 10.4 1.2 13.3 6.8 10.1 1.3 13.3 6.8 140 7 130 165 10.2 0 10.6 10.1 09/13/2006 22:00:00 11.2 1.1 13.7 7.6 11.3 1.1 14.1 8 10.9 1.1 13.3 8 137 8 137 165 10.3 0 10.6 10.1 09/13/2006 22:10:00 10.9 1.1 13.7 6.8 11 1.1 14.1 7.2 10.5 1.3 14.1 6.8 131 8 135 165 10.3 0 10.6 10.1 09/13/2006 22:20:00 9.4 1.3 12.6 5.7 9.5 1.3 13 6.1 9.3 1.2 12.2 6.8 128 7 117 165 10.3 0 10.6 10.3 09/13/2006 22:30:00 9.4 1.1 12.2 6.5 9.5 1.2 12.2 6.8 9.2 1.2 12.2 6.5 127 8 127 165 10.4 0 10.6 10.3 09/13/2006 22:40:00 9.5 1.1 12.6 6.5 9.6 1.1 12.6 6.1 9.2 1.2 12.2 6.1 128 8 136 165 10.5 0 10.9 10.3 09/13/2006 22:50:00 9.6 1.1 13.3 6.8 9.6 1.1 13.3 7.2 9.4 1.2 13 6.1 130 7 129 165 10.5 0 10.9 10.3 09/13/2006 23:00:00 10.1 1 13 7.2 10.2 1 13 6.8 10 1.1 13 6.8 129 6 130 165 10.4 0 10.6 10.3 09/13/2006 23:10:00 10.5 1 13.7 8 10.6 1.1 13.3 8 10.3 1.1 13 7.2 126 6 128 165 10.4 0 10.9 10.3 09/13/2006 23:20:00 10.1 0.9 13 8 10.3 0.9 12.6 7.6 9.9 1 12.6 6.8 127 5 133 165 10.3 0 10.6 10.3 09/13/2006 23:30:00 10.3 0.7 12.6 8.4 10.4 0.7 12.6 8.8 10.1 0.8 12.6 7.6 125 4 128 165 10.3 0 10.9 10.1 09/13/2006 23:40:00 10 0.8 12.2 8 10.1 0.8 12.6 8 9.8 0.8 12.2 7.6 127 5 130 165 10.3 0 10.6 10.1 09/13/2006 23:50:00 10.6 0.7 12.2 8.8 10.8 0.7 12.6 8.8 10.4 0.8 11.8 7.6 127 5 124 165 10.3 0 10.6 10.1 09/14/2006 00:00:00 11.4 0.8 13.3 9.5 11.6 0.8 14.1 9.5 11.3 0.9 13.3 8.8 126 5 123 165 10.3 0 10.6 10.1 09/14/2006 00:10:00 11.7 0.8 13.7 8.8 11.9 0.9 14.1 8.8 11.5 1 13.7 8 129 5 132 165 10.3 0 10.6 10.1 09/14/2006 00:20:00 11.3 0.8 13 9.1 11.5 0.8 13.3 8.4 11.2 0.9 13.3 8 129 5 123 165 10.3 0 10.6 10.1 09/14/2006 00:30:00 11.3 0.7 13.3 9.5 11.5 0.7 13.7 9.9 11.3 0.7 13.3 9.1 127 5 128 165 10.3 0 10.6 10.1 09/14/2006 00:40:00 11.4 1 14.1 8.4 11.6 1 14.1 9.1 11.3 1 14.1 8.4 127 5 131 165 10.4 0 10.6 10.3 09/14/2006 00:50:00 10.6 1.1 13.3 8 10.7 1.2 13.7 8 10.3 1.2 13.7 7.2 135 6 119 165 10.5 0.1 10.9 10.1 09/14/2006 01:00:00 10.4 1 12.6 7.6 10.4 1 12.6 8 10.1 1 12.6 7.6 141 6 143 165 10.5 0.1 10.9 10.3 09/14/2006 01:10:00 10.2 1.3 13.3 7.2 10.3 1.3 13.3 7.2 9.8 1.4 12.6 6.8 138 7 139 165 10.6 0.1 10.9 10.3 09/14/2006 01:20:00 10.9 0.9 13.3 7.6 11 0.9 13 7.6 10.6 0.9 12.6 8 138 6 128 165 10.7 0.1 10.9 10.3 09/14/2006 01:30:00 10.5 0.8 12.2 8.4 10.6 0.8 12.6 8.4 10.2 1 12.2 6.5 138 6 137 165 10.7 0.1 10.9 10.6 09/14/2006 01:40:00 10 1 12.6 7.6 10.1 1 13 7.6 9.8 1.1 12.6 7.2 138 6 138 165 10.8 0 11.1 10.6 09/14/2006 01:50:00 10.4 0.9 12.6 7.6 10.5 0.9 12.6 8 10.1 1 13 7.2 138 7 123 165 10.9 0 11.1 10.6 09/14/2006 02:00:00 9.9 1 12.6 7.6 10 1 12.2 7.6 9.8 1 12.6 7.2 136 7 144 165 10.9 0 11.1 10.9 09/14/2006 02:10:00 9 1 11.5 6.5 9.1 1 11.8 6.5 8.8 1 11.8 5.7 137 8 138 165 10.9 0 11.1 10.9 09/14/2006 02:20:00 8.6 1.1 11.1 5.7 8.6 1.1 11.5 6.1 8.5 1 11.1 6.5 143 8 135 165 11 0 11.1 10.9 09/14/2006 02:30:00 9.1 0.9 11.1 6.8 9.2 0.9 11.1 6.5 9 1 11.5 6.1 138 8 136 165 11 0 11.4 10.9 09/14/2006 02:40:00 9.1 1.3 11.8 5.3 9.1 1.2 12.2 5.7 9 1.3 12.2 6.1 141 9 143 165 11.1 0 11.4 10.9 09/14/2006 02:50:00 8 1 11.5 5.7 8 1 11.8 5.7 7.9 1 11.5 5.7 142 9 123 165 11.1 0 11.4 10.9 09/14/2006 03:00:00 6.9 0.8 9.5 4.6 6.8 0.8 9.1 4.9 6.7 0.8 8.8 4.6 140 9 163 165 11.1 0 11.4 10.9 09/14/2006 03:10:00 9.3 1.1 12.2 6.1 9.4 1.1 12.2 6.8 9.3 1.1 12.2 5.7 141 8 147 165 11.1 0 11.4 10.9 09/14/2006 03:20:00 12.1 0.9 14.5 9.5 12.1 0.9 14.1 9.5 12 0.9 14.5 9.9 148 4 153 165 11.1 0 11.4 10.9 09/14/2006 03:30:00 12.6 0.9 14.9 10.7 12.7 0.9 15.3 10.7 12.3 0.9 14.9 9.1 146 4 145 165 11.1 0 11.4 10.9 09/14/2006 03:40:00 13.3 1 16.4 10.7 13.4 1 16.4 10.7 12.9 1.1 16.1 9.5 144 5 141 165 11.1 0 11.4 10.9 09/14/2006 03:50:00 13.7 1.1 16.1 10.3 13.7 1.2 16.1 10.3 13.4 1.3 16.1 9.9 146 4 150 165 11.2 0 11.4 10.9 09/14/2006 04:00:00 13.4 0.8 15.3 10.3 13.4 0.8 15.3 10.7 13 0.8 14.9 10.3 148 5 136 165 11.2 0.1 11.4 10.9 09/14/2006 04:10:00 13 0.9 15.3 10.7 13.1 0.9 14.9 10.7 12.9 1 14.9 10.3 149 3 153 165 11.1 0 11.4 10.9 09/14/2006 04:20:00 12.2 0.6 14.1 10.7 12.1 0.6 13.7 10.3 12.1 0.7 13.7 9.9 152 3 154 165 11.1 0 11.4 10.9 09/14/2006 04:30:00 12.9 0.7 14.9 11.5 12.9 0.7 14.9 11.5 12.8 0.7 15.3 10.7 149 3 153 165 11.1 0 11.4 10.9 09/14/2006 04:40:00 12.7 0.6 14.1 11.1 12.7 0.6 14.1 11.1 12.7 0.6 14.1 11.1 149 4 151 165 11.3 0 11.7 11.1 09/14/2006 04:50:00 12.7 0.8 15.3 10.3 12.7 0.8 15.3 10.3 12.7 0.8 15.3 10.3 148 5 155 165 11.3 0 11.7 11.1 09/14/2006 05:00:00 12.1 0.9 14.5 9.9 12.1 0.8 14.5 9.9 12 0.9 14.1 9.5 149 4 150 165 11.3 0 11.7 11.1 09/14/2006 05:10:00 11.8 0.8 13.7 9.9 11.8 0.8 13.7 9.9 11.6 0.8 13.3 9.5 147 4 151 165 11.3 0 11.7 11.1 09/14/2006 05:20:00 11.6 0.9 13.7 9.5 11.6 0.9 13.7 9.5 11.4 0.9 13.7 9.5 145 5 142 165 11.3 0 11.7 11.1 09/14/2006 05:30:00 12.2 1 14.9 9.5 12.2 1 14.9 9.5 12.2 0.9 14.5 10.3 147 5 145 165 11.3 0 11.7 11.1 09/14/2006 05:40:00 12 1.1 14.9 9.5 12 1 14.9 9.5 11.9 1.1 14.9 8.8 148 5 148 165 11.4 0 11.7 11.1 09/14/2006 05:50:00 11.7 0.9 14.5 8.8 11.8 0.9 14.1 8.8 11.6 0.9 14.1 8.8 146 6 148 165 11.4 0 11.7 11.1 09/14/2006 06:00:00 11.3 1 13.3 8.8 11.3 1 13.3 8.8 11.2 1.1 14.1 8.4 147 5 142 165 11.5 0 11.7 11.4 09/14/2006 06:10:00 10.6 0.8 13.3 8 10.7 0.8 13.3 8 10.5 0.9 13 8 144 7 139 165 11.4 0 11.7 11.1 09/14/2006 06:20:00 11.5 0.9 13.7 9.1 11.4 0.8 13.7 9.1 11.4 1 14.1 8.8 148 6 152 165 11.5 0 11.7 11.1 09/14/2006 06:30:00 11.7 1.1 14.1 8.8 11.8 1.1 14.1 8.8 11.6 1.2 14.1 7.6 146 6 154 165 11.5 0 11.7 11.1 09/14/2006 06:40:00 11.2 1 14.5 8.4 11.3 1 14.1 8.4 10.8 1 13.3 7.6 141 6 158 165 11.6 0 11.9 11.1 09/14/2006 06:50:00 12.2 1.3 15.3 9.1 12.3 1.3 15.3 9.1 11.8 1.2 14.9 8 140 8 145 165 11.7 0 11.9 11.7 09/14/2006 07:00:00 11.5 1.2 14.1 7.6 11.6 1.2 14.5 7.2 11.3 1.1 14.1 8 144 5 143 165 11.8 0 11.9 11.7 09/14/2006 07:10:00 11.5 1.1 13.7 8.4 11.6 1.1 14.1 8.4 11.4 1.2 13.7 8.4 145 6 135 165 11.7 0 11.9 11.7 09/14/2006 07:20:00 11.3 0.8 13.3 9.1 11.3 0.8 13.3 9.5 11.2 0.8 13.3 9.1 147 5 150 165 11.7 0 11.9 11.7 09/14/2006 07:30:00 10.6 0.9 13.3 8.4 10.6 0.9 13.3 8 10.4 0.8 12.6 8.4 145 7 128 165 11.7 0 11.9 11.4 09/14/2006 07:40:00 10.9 0.9 13.7 8.4 11 0.8 13.7 8.8 10.8 0.9 13.3 7.2 145 7 139 165 11.7 0 12.2 11.7 09/14/2006 07:50:00 11.3 1 14.1 8.4 11.3 1 13.7 8.4 11 0.9 13 8 146 6 154 165 11.7 0 11.9 11.7 09/14/2006 08:00:00 10.6 0.9 13.7 8.8 10.6 0.9 13.3 8.8 10.4 0.8 12.6 8.4 147 5 149 165 11.7 0 11.9 11.4 09/14/2006 08:10:00 10.5 1 13.3 7.2 10.6 0.9 13 8 10.4 1 12.6 7.6 148 5 150 165 11.8 0 11.9 11.4 09/14/2006 08:20:00 11.4 1.2 14.9 8 11.4 1.2 14.5 8.4 11.4 1.1 13.7 8.8 147 7 145 165 11.8 0 11.9 11.7 09/14/2006 08:30:00 11.1 0.9 13.7 7.6 11.2 0.9 13.7 8 11 1 13 7.6 144 6 146 165 11.8 0 11.9 11.4 09/14/2006 08:40:00 11.4 0.8 13.7 9.5 11.4 0.8 13.3 9.1 11.2 0.8 13.7 9.1 145 6 143 165 11.8 0 11.9 11.4 09/14/2006 08:50:00 10.8 1 13.7 8.8 10.9 1 13.7 8.8 10.6 1.1 13.7 7.6 145 6 149 165 11.8 0 11.9 11.7 09/14/2006 09:00:00 11.1 1 13.3 9.1 11.1 0.9 13.3 9.1 10.9 1 14.1 8.4 147 5 150 165 11.8 0 11.9 11.4 09/14/2006 09:10:00 10.4 0.8 12.6 8.4 10.4 0.8 12.2 8 10.2 0.9 11.8 7.6 148 6 139 165 11.7 0 11.9 11.4 09/14/2006 09:20:00 10.5 0.9 14.1 8.4 10.6 0.8 14.5 8.4 10.3 1 13.3 8 145 6 151 165 11.7 0 11.9 11.4 09/14/2006 09:30:00 11.2 1.1 14.1 7.6 11.2 1.1 14.1 8 10.9 1.2 13.7 6.8 143 6 146 165 11.7 0 11.9 11.4 09/14/2006 09:40:00 10.3 0.7 12.2 8 10.3 0.7 12.2 8.8 10.1 0.8 12.2 8.4 144 6 154 165 11.7 0 12.2 11.4 09/14/2006 09:50:00 11.1 1 13 8.4 11.2 1 13 8.4 10.9 1.1 13 7.2 143 5 150 165 11.7 0 11.9 11.4 09/14/2006 10:00:00 10.2 0.8 12.2 8 10.3 0.8 12.6 8 10.2 0.8 12.6 7.6 146 4 153 165 11.8 0 11.9 11.4 09/14/2006 10:10:00 11.1 1.2 13.7 6.5 11.2 1.2 13.7 6.5 10.9 1.1 13 7.2 142 6 147 165 11.7 0 12.2 11.4 09/14/2006 10:20:00 12.3 0.6 13.7 10.3 12.4 0.6 14.5 10.7 12.2 0.7 14.5 9.9 145 5 144 165 11.7 0 11.9 11.7 09/14/2006 10:30:00 11.5 0.5 13 10.3 11.5 0.5 13 9.9 11.4 0.6 13 9.9 149 4 153 165 11.7 0 11.9 11.4 09/14/2006 10:40:00 10.5 0.7 12.6 8.8 10.5 0.7 12.6 8.8 10.2 0.8 12.6 8 148 4 141 165 11.7 0 12.2 11.4 09/14/2006 10:50:00 10.7 1 13 7.6 10.7 1 13.3 7.6 10.6 1.1 13.3 8 149 6 150 165 11.7 0 11.9 11.4 09/14/2006 11:00:00 10.9 0.9 12.6 8 10.9 0.9 12.6 8 10.8 1 13 8.4 146 5 156 165 11.6 0 11.7 11.4 09/14/2006 11:10:00 11.2 0.7 12.6 9.1 11.2 0.7 12.6 9.5 11.1 0.7 13.3 8.8 144 5 148 165 11.7 0 11.9 11.4 09/14/2006 11:20:00 10.5 0.7 12.2 8.8 10.5 0.7 11.8 8.4 10.5 0.7 12.6 8.4 147 5 148 165 11.6 0 11.9 11.4 09/14/2006 11:30:00 11 0.8 13 8.8 11.1 0.8 13.3 8.8 10.8 1 13 8.8 143 5 148 165 11.7 0 12.2 11.4 09/14/2006 11:40:00 11 1 13 8.4 11.1 0.9 13 8.4 10.7 1.1 13.3 7.6 145 5 149 165 11.7 0 11.9 11.7 09/14/2006 11:50:00 9.9 1.1 12.6 6.5 9.9 1.2 13 6.5 9.4 1.3 12.6 5.7 143 6 145 165 11.7 0 11.9 11.7 09/14/2006 12:00:00 11.6 1.3 15.3 8.8 11.7 1.2 14.9 8.4 11.3 1.2 15.3 7.6 142 5 145 165 11.7 0 11.9 11.7 09/14/2006 12:10:00 10 1.1 13 7.2 10.1 1.1 13.3 6.8 9.6 1.1 13 6.5 140 7 139 165 11.8 0 11.9 11.7 09/14/2006 12:20:00 9.6 0.9 12.2 6.8 9.7 0.9 12.2 7.2 9.2 1 11.1 6.5 139 6 136 165 11.9 0 11.9 11.7 09/14/2006 12:30:00 9.4 0.9 11.5 6.8 9.5 0.9 11.5 7.2 9.1 1.1 11.8 5.7 138 7 142 165 11.9 0.1 12.2 11.1 09/14/2006 12:40:00 8.9 1.1 11.5 5.7 8.9 1.1 11.8 6.1 8.5 1 11.1 6.5 139 8 134 165 11.7 0.2 11.9 11.1 09/14/2006 12:50:00 10.2 1 13 7.6 10.3 1.1 13.3 7.6 9.8 1.2 13.7 6.5 135 7 129 165 11.7 0.2 11.9 11.1 09/14/2006 13:00:00 10.2 1 12.6 7.2 10.2 1 13 7.2 9.5 1.2 13 6.1 136 6 139 165 11.7 0 11.9 11.1 09/14/2006 13:10:00 10 0.8 12.2 7.6 10.1 0.9 12.6 7.6 9.4 1 12.2 6.8 137 7 125 165 11.8 0.2 12.2 11.1 09/14/2006 13:20:00 10 0.7 11.8 8 10.2 0.8 11.8 7.6 9.7 0.8 11.5 6.5 140 5 145 165 11.9 0.1 12.2 11.4 09/14/2006 13:30:00 9.3 0.8 11.1 6.1 9.4 0.8 11.5 6.5 8.9 0.9 10.7 6.1 140 6 144 165 12 0 12.2 11.4 09/14/2006 13:40:00 9.2 0.7 11.1 7.2 9.3 0.7 11.1 6.8 8.8 0.8 10.7 5.7 140 5 141 165 12 0 12.2 11.7 09/14/2006 13:50:00 8.4 1 10.7 4.9 8.4 1 10.7 5.3 7.9 1 9.9 4.9 139 8 134 165 11.9 0 12.5 11.4 09/14/2006 14:00:00 7.5 1.1 9.9 4.2 7.5 1.1 9.9 4.2 7.1 1 9.9 4.6 135 7 137 165 11.9 0 12.2 11.7 09/14/2006 14:10:00 6.8 1 9.5 4.2 6.8 1 9.5 4.2 6.5 1 9.1 2.6 136 9 143 165 11.9 0.1 12.2 11.4 09/14/2006 14:20:00 6.8 0.7 8.8 4.6 6.9 0.8 9.1 4.6 6.4 0.8 9.1 4.6 131 7 121 165 11.8 0.1 12.2 11.4 09/14/2006 14:30:00 6.7 0.9 8.8 4.2 6.8 0.9 8.8 3.4 6.6 1 8.8 3.8 131 8 141 165 11.8 0.2 12.5 11.1 09/14/2006 14:40:00 7.1 0.8 9.1 5.3 7.2 0.8 9.5 5.3 6.8 0.9 9.1 4.9 132 8 132 165 11.9 0.1 12.5 11.4 09/14/2006 14:50:00 6.3 0.6 8 4.6 6.3 0.7 8 4.6 6 0.7 8 4.6 131 8 121 165 12 0 12.2 11.4 09/14/2006 15:00:00 7.3 1 9.1 4.6 7.3 1 9.1 4.6 6.9 1 9.1 4.6 131 6 139 165 12 0 12.2 11.9 09/14/2006 15:10:00 8.1 0.7 9.5 5.3 8.1 0.8 9.5 5.3 7.9 0.9 9.9 5.3 137 5 138 165 12.1 0 12.2 11.9 09/14/2006 15:20:00 8.2 0.8 9.9 5.7 8.2 0.8 10.3 5.7 7.9 0.9 10.3 4.6 136 6 136 165 12.1 0 12.2 11.9 09/14/2006 15:30:00 8.5 0.8 10.3 6.1 8.5 0.8 10.3 6.1 8.2 1 9.9 5.7 136 5 144 165 12.1 0 12.2 11.9 09/14/2006 15:40:00 8 0.8 9.9 5.3 8 0.8 9.9 5.3 7.7 0.9 9.9 4.2 137 6 134 165 11.9 0 12.5 11.9 09/14/2006 15:50:00 7 0.8 9.1 4.6 7 0.8 9.1 4.6 6.7 0.8 8.8 4.6 135 7 145 165 11.9 0 12.2 11.9 09/14/2006 16:00:00 6.9 0.7 8.8 4.9 6.9 0.7 8.8 4.6 6.6 0.8 8.4 4.6 136 7 122 165 11.9 0 11.9 11.9 09/14/2006 16:10:00 6.3 0.7 8 4.2 6.2 0.7 8 3.8 5.9 0.8 8 4.2 133 6 131 165 12 0 12.5 11.9 09/14/2006 16:20:00 6.2 0.6 8.8 4.6 6.1 0.7 8.4 4.6 5.9 0.8 8 3.8 136 7 126 165 12.1 0 12.2 11.9 09/14/2006 16:30:00 6 0.8 7.6 4.2 5.9 0.8 7.6 3.8 5.8 0.9 8 3.4 139 7 148 165 12.1 0 12.7 11.9 09/14/2006 16:40:00 6.5 1 8.8 4.2 6.4 1 8.8 3.8 6.3 1 8.8 3 138 7 129 165 11.9 0 12.2 11.9 09/14/2006 16:50:00 6.3 0.7 8 4.2 6.2 0.7 7.6 4.2 5.9 0.7 8 4.2 137 8 135 165 11.9 0 11.9 11.7 09/14/2006 17:00:00 5.9 0.8 8 4.2 5.8 0.8 8 3.8 5.4 0.9 7.2 3 137 7 136 165 11.8 0 11.9 11.4 09/14/2006 17:10:00 5.9 0.8 8 4.2 5.9 0.8 8.4 4.2 5.5 0.9 8 3.4 134 7 137 165 11.8 0.2 11.9 11.1 09/14/2006 17:20:00 6.4 0.8 8.4 4.6 6.3 0.8 8 4.2 6 0.9 8 3.8 135 6 145 165 11.8 0.2 11.9 11.1 09/14/2006 17:30:00 6.9 0.8 9.1 4.6 6.9 0.7 9.1 4.6 6.5 0.8 8.4 4.6 135 7 145 165 11.7 0.2 11.9 11.1 09/14/2006 17:40:00 7.3 0.7 8.8 4.9 7.2 0.7 9.1 5.3 6.8 0.8 9.1 4.9 136 6 142 165 11.7 0.2 12.2 11.1 09/14/2006 17:50:00 7 0.7 8.8 4.6 7 0.8 8.4 4.6 6.6 0.8 8.4 3.8 136 6 138 165 11.7 0.2 11.9 11.1 09/14/2006 18:00:00 6.4 0.7 8.4 4.6 6.3 0.7 8.4 4.6 6 0.8 8 3.8 140 5 143 165 11.7 0 11.9 11.4 09/14/2006 18:10:00 6 0.6 7.6 4.2 5.9 0.6 8 4.2 5.8 0.6 7.2 3.8 138 6 130 165 11.7 0 11.9 11.4 09/14/2006 18:20:00 6.6 0.7 8.4 4.6 6.6 0.7 8.4 4.9 6.3 0.8 8 4.2 136 5 142 165 11.7 0 11.9 11.7 09/14/2006 18:30:00 7 0.7 9.1 4.9 6.9 0.8 9.1 4.9 6.5 0.8 8.4 4.2 136 6 135 165 11.7 0 11.9 11.4 09/14/2006 18:40:00 7.2 0.6 8.8 5.3 7.2 0.7 8.8 5.3 6.7 0.7 8.4 4.9 137 5 147 165 11.7 0 12.2 11.4 09/14/2006 18:50:00 6.9 0.6 8.8 5.7 6.9 0.6 9.1 5.3 6.6 0.8 8.8 4.2 136 5 135 165 11.7 0 11.9 11.1 09/14/2006 19:00:00 6.5 0.8 8.8 4.6 6.5 0.8 8.8 4.6 6.3 0.7 8.8 4.2 137 5 144 165 11.7 0 11.9 11.4 09/14/2006 19:10:00 6.8 0.6 8.4 4.6 6.8 0.6 8.4 4.2 6.5 0.8 8.4 4.2 139 6 130 165 11.7 0 11.9 11.4 09/14/2006 19:20:00 6.3 0.8 8.4 4.2 6.3 0.8 8.4 4.2 5.8 0.8 8 4.2 135 7 127 165 11.6 0 11.7 11.4 09/14/2006 19:30:00 5.4 0.7 7.2 3 5.3 0.7 7.2 2.6 5 0.7 6.8 2.6 133 7 135 165 11.5 0 11.9 11.4 09/14/2006 19:40:00 5.4 0.7 7.2 3.4 5.4 0.7 6.8 3.4 5.3 0.7 7.2 3.8 132 7 128 165 11.6 0 11.9 11.4 09/14/2006 19:50:00 5.7 0.7 7.6 4.2 5.7 0.7 7.2 4.2 5.4 0.6 7.2 3.8 131 5 137 165 11.6 0 11.9 11.4 09/14/2006 20:00:00 6.4 0.8 8 3.8 6.4 0.8 8 3.8 6.1 0.9 8.4 3.8 133 6 140 165 11.5 0 11.7 11.4 09/14/2006 20:10:00 5.8 0.9 7.6 3.4 5.7 0.9 8 3.4 5.5 0.9 7.6 3 133 7 138 165 11.6 0 11.9 11.4 09/14/2006 20:20:00 5.6 0.8 7.2 3.8 5.7 0.9 7.6 3.8 5.5 0.8 7.6 3 128 6 126 165 11.5 0 11.7 11.4 09/14/2006 20:30:00 6.6 0.7 8.4 4.9 6.7 0.7 8.8 4.9 6.6 0.6 8.4 4.9 131 6 139 165 11.5 0 11.7 11.4 09/14/2006 20:40:00 7.3 1 9.5 4.9 7.4 1 9.9 4.9 7 0.9 9.5 4.6 136 6 137 165 11.4 0 11.7 11.1 09/14/2006 20:50:00 7 1 9.5 4.9 7 1 9.1 4.6 6.8 0.9 9.1 4.2 136 6 136 165 11.4 0 11.7 11.1 09/14/2006 21:00:00 7.8 0.8 9.9 5.7 7.8 0.8 9.5 5.7 7.4 0.8 9.1 5.3 136 6 135 165 11.4 0 11.7 11.1 09/14/2006 21:10:00 6.9 0.8 8.8 4.9 6.9 0.8 8.8 4.9 6.7 0.8 8.8 4.9 138 8 150 165 11.3 0 11.7 11.1 09/14/2006 21:20:00 5.7 0.8 8 3.8 5.7 0.9 8 3.4 5.6 0.9 7.6 3 138 8 131 165 11.3 0 11.7 11.1 09/14/2006 21:30:00 5.7 0.6 7.2 3.8 5.7 0.7 7.2 3.8 5.5 0.6 7.6 4.2 134 7 141 165 11.3 0 11.7 11.1 09/14/2006 21:40:00 6.1 0.6 8 4.6 6.2 0.6 8 4.2 6 0.6 8 3.8 132 5 132 165 11.3 0 11.7 11.1 09/14/2006 21:50:00 5.2 1 7.6 2.6 5.1 1 7.6 2.6 5.1 1 7.2 2.6 135 9 124 165 11.4 0 11.7 11.1 09/14/2006 22:00:00 4.2 0.5 5.7 3 4.2 0.5 5.3 2.6 4.2 0.5 5.3 3 132 8 141 165 11.4 0 11.7 11.1 09/14/2006 22:10:00 5.2 0.6 6.5 3.4 5.1 0.6 6.5 3.4 5.1 0.7 6.8 3.4 135 8 134 165 11.3 0 11.7 11.1 09/14/2006 22:20:00 4.4 0.6 5.7 3 4.4 0.6 5.7 3 4.5 0.6 6.1 3 137 9 129 165 11.3 0 11.4 11.1 09/14/2006 22:30:00 5.1 0.6 7.2 3 5.1 0.7 7.6 3 5 0.7 7.2 3.4 128 7 124 165 11.2 0 11.4 10.9 09/14/2006 22:40:00 4.5 1 7.2 2.3 4.5 1 7.2 2.3 4.4 1 7.2 2.6 128 8 124 165 11.2 0.1 11.4 10.9 09/14/2006 22:50:00 4.5 0.6 6.1 3 4.6 0.6 6.1 3 4.5 0.5 6.1 3 128 6 131 165 11.2 0.1 11.4 10.9 09/14/2006 23:00:00 4.4 0.6 6.1 2.3 4.5 0.6 6.1 2.3 4.4 0.6 5.7 3 124 8 136 165 11.1 0 11.4 10.9 09/14/2006 23:10:00 5.6 1.2 8.4 2.3 5.7 1.2 8.4 2.6 5.6 1.2 8 2.6 131 9 135 165 11.1 0.1 11.4 10.9 09/14/2006 23:20:00 4.5 1 7.6 2.3 4.6 1 8 1.5 4.3 1.1 7.2 1.9 129 10 125 165 11.1 0.1 11.4 10.9 09/14/2006 23:30:00 5.4 0.7 7.2 3 5.4 0.7 7.2 2.6 5.2 0.8 7.2 2.6 129 7 135 165 11.1 0 11.4 10.9 09/14/2006 23:40:00 5.3 0.7 7.6 3.4 5.4 0.7 7.6 3.4 5.3 0.7 8 3 131 8 134 165 11 0.1 11.4 10.9 09/14/2006 23:50:00 4.8 0.6 6.5 3 4.8 0.6 6.5 3 4.7 0.5 6.1 3.4 132 9 143 165 11 0.1 11.4 10.9 09/15/2006 00:00:00 5 0.8 6.5 2.6 5.1 0.8 6.8 2.6 5.1 0.7 6.5 3.4 135 9 145 165 11.1 0.1 11.4 10.9 09/15/2006 00:10:00 5 0.7 6.5 2.3 5 0.7 6.5 2.3 4.9 0.6 6.5 3 127 8 128 165 11.1 0.1 11.4 10.9 09/15/2006 00:20:00 5.5 0.6 7.6 4.2 5.6 0.6 7.6 3.8 5.4 0.5 6.8 3.8 127 7 132 165 11.1 0.1 11.4 10.9 09/15/2006 00:30:00 5.3 0.6 7.2 3.8 5.3 0.6 6.8 3.8 5 0.6 6.8 3.4 130 7 131 165 11.1 0.2 11.4 10.9 09/15/2006 00:40:00 5 0.7 6.5 2.6 5 0.7 6.5 2.6 5 0.7 6.5 3 133 7 126 165 11.1 0.2 11.4 10.9 09/15/2006 00:50:00 5.1 0.8 6.8 3.4 5.1 0.9 7.2 3.4 4.8 0.8 6.8 3 136 7 136 165 11.1 0.2 11.4 10.9 09/15/2006 01:00:00 6.1 0.7 8.4 4.2 6.1 0.8 8.4 4.2 5.8 0.8 8 4.2 137 6 147 165 11.1 0.2 11.4 10.9 09/15/2006 01:10:00 6.1 0.7 8.4 4.6 6.1 0.7 8.4 4.2 5.9 0.8 7.6 3.4 138 7 138 165 11.1 0.2 11.4 10.9 09/15/2006 01:20:00 6.3 0.8 8.4 4.2 6.4 0.9 8.4 4.2 6 1 8.4 3.8 131 7 135 165 11.3 0.1 11.7 10.9 09/15/2006 01:30:00 6.8 1.1 9.1 4.6 6.9 1.1 9.1 4.6 6.7 1.1 9.1 4.2 131 8 122 165 11.5 0.1 11.7 11.1 09/15/2006 01:40:00 8.6 1.1 11.1 6.1 8.7 1.1 11.5 6.1 8.4 1.2 11.1 5.7 135 6 136 165 11.4 0 11.7 11.1 09/15/2006 01:50:00 9.4 0.9 11.1 6.1 9.5 1 11.1 6.1 9.1 1 11.1 6.5 138 6 146 165 11.3 0 11.4 11.1 09/15/2006 02:00:00 9.2 1.2 11.8 6.5 9.3 1.2 11.8 6.1 9.1 1.2 11.8 6.1 140 6 141 165 11.2 0.1 11.4 10.9 09/15/2006 02:10:00 8.1 0.9 10.3 5.7 8.2 0.9 10.7 5.7 7.9 1 10.3 5.3 140 8 147 165 11.1 0.1 11.4 10.9 09/15/2006 02:20:00 8.9 0.8 11.5 7.2 9 0.8 11.1 7.2 8.5 0.9 10.7 6.1 140 6 149 165 11.1 0.1 11.4 10.9 09/15/2006 02:30:00 9.2 0.8 11.1 6.8 9.3 0.8 11.1 6.8 9 0.9 11.5 6.5 141 5 138 165 11.2 0.1 11.7 10.9 09/15/2006 02:40:00 9 0.7 10.7 7.6 9.1 0.7 11.1 7.6 8.8 0.7 10.7 6.5 143 5 145 165 11.2 0 11.7 10.9 09/15/2006 02:50:00 9.7 0.6 11.1 7.6 9.7 0.6 11.1 8 9.5 0.6 10.7 7.6 145 4 139 165 11.3 0 11.7 11.1 09/15/2006 03:00:00 8.9 0.5 9.9 7.2 8.9 0.5 9.9 7.2 8.6 0.6 9.9 6.8 145 4 148 165 11.2 0 11.4 11.1 09/15/2006 03:10:00 9.3 0.5 10.7 8 9.3 0.5 10.7 8 9 0.6 10.7 7.2 145 3 145 165 11.2 0.1 11.4 10.9 09/15/2006 03:20:00 8.6 0.6 10.3 6.8 8.6 0.6 10.3 7.2 8.3 0.6 9.9 6.8 144 3 146 165 11.2 0.1 11.4 10.9 09/15/2006 03:30:00 7.5 0.8 9.1 5.7 7.6 0.8 9.1 5.7 7.4 0.8 9.1 4.9 143 4 143 165 11.1 0.1 11.4 10.9 09/15/2006 03:40:00 7.4 0.5 8.4 5.7 7.4 0.4 8.4 6.1 7.2 0.6 8.4 5.7 146 4 146 165 11.3 0.1 11.7 10.9 09/15/2006 03:50:00 8.7 0.5 9.9 7.2 8.7 0.5 9.9 7.2 8.5 0.6 9.9 6.1 144 4 151 165 11.3 0.1 11.7 11.1 09/15/2006 04:00:00 9.3 0.7 11.5 7.6 9.4 0.7 11.1 7.6 9 0.8 11.1 6.5 139 5 129 165 11.1 0.1 11.4 10.9 09/15/2006 04:10:00 9.9 0.7 11.5 7.6 9.9 0.7 11.5 7.2 9.6 0.8 11.5 7.2 143 4 144 165 11.2 0.1 11.7 10.9 09/15/2006 04:20:00 9.1 0.6 10.7 7.2 9.1 0.6 10.3 7.6 8.7 0.7 10.3 6.1 146 4 146 165 11.1 0.1 11.4 10.9 09/15/2006 04:30:00 8.9 0.4 9.9 7.6 9 0.5 10.3 7.2 8.6 0.6 9.9 6.8 144 3 148 165 11.1 0.1 11.4 10.9 09/15/2006 04:40:00 9.4 0.6 10.7 8 9.5 0.6 11.1 8 9 0.7 10.7 6.8 144 4 147 165 11.1 0.1 11.4 10.9 09/15/2006 04:50:00 10.3 0.5 11.8 8.8 10.3 0.6 12.2 8.4 9.9 0.7 12.2 8 143 3 143 165 11.1 0.1 11.4 10.9 09/15/2006 05:00:00 10.6 0.7 12.2 8.8 10.7 0.6 12.2 9.1 10.2 0.7 12.2 8 143 3 144 165 11.1 0.1 11.4 10.9 09/15/2006 05:10:00 9.6 0.6 11.1 8 9.7 0.6 11.5 7.6 9.3 0.7 11.1 6.8 143 4 140 165 11 0.1 11.4 10.9 09/15/2006 05:20:00 9.9 0.6 11.5 8 9.9 0.6 11.5 8 9.6 0.7 11.1 7.2 145 3 145 165 11 0 11.1 10.6 09/15/2006 05:30:00 9.2 0.6 11.1 7.2 9.3 0.6 11.1 7.6 9.1 0.6 10.7 7.2 146 3 145 165 10.9 0 11.1 10.6 09/15/2006 05:40:00 8.9 0.5 10.3 7.2 8.9 0.5 10.7 6.8 8.7 0.6 10.3 6.8 145 5 145 165 10.9 0 11.1 10.6 09/15/2006 05:50:00 9.3 0.7 11.1 7.2 9.3 0.7 11.5 7.2 9 0.8 10.7 6.8 144 4 143 165 10.9 0.1 11.1 10.6 09/15/2006 06:00:00 9.8 0.7 11.8 8 9.8 0.7 11.5 8.4 9.5 0.8 11.5 7.6 143 5 143 165 10.8 0.1 11.1 10.3 09/15/2006 06:10:00 9.7 0.7 11.1 7.2 9.8 0.7 11.1 7.2 9.6 0.7 11.1 7.6 143 4 143 165 10.7 0.1 11.1 10.3 09/15/2006 06:20:00 9.5 0.6 11.1 8 9.5 0.6 10.7 8 9.4 0.6 10.7 7.6 144 4 145 165 10.6 0.2 11.1 10.3 09/15/2006 06:30:00 9.2 0.5 10.3 7.2 9.2 0.5 10.3 7.6 9.1 0.7 10.7 6.8 145 4 144 165 10.7 0.2 11.1 10.1 09/15/2006 06:40:00 9.1 0.8 11.5 7.2 9.1 0.8 11.8 7.2 8.9 0.8 10.7 7.2 145 4 134 165 10.7 0.2 11.1 10.3 09/15/2006 06:50:00 8.9 0.8 11.1 7.2 9 0.8 11.1 7.2 8.8 0.9 11.1 6.8 141 5 132 165 10.6 0.2 10.9 10.3 09/15/2006 07:00:00 9.7 0.8 11.5 7.6 9.8 0.8 11.5 7.6 9.6 0.9 11.5 6.8 141 6 144 165 10.6 0.2 11.1 10.3 09/15/2006 07:10:00 9.9 0.8 11.8 7.2 10 0.8 11.8 6.8 9.8 0.9 11.8 7.2 141 6 143 165 10.5 0.3 10.9 10.3 09/15/2006 07:20:00 10.7 0.8 13.3 9.1 10.7 0.8 13.7 9.1 10.5 0.8 13 8.8 142 5 141 165 10.5 0.3 10.9 10.1 09/15/2006 07:30:00 10.6 1 13 7.2 10.6 1 13.3 6.8 10.3 1.1 13.3 6.5 140 6 136 165 10.5 0.3 11.1 10.3 09/15/2006 07:40:00 10.7 0.9 13 7.2 10.7 1 13.3 6.8 10.4 1 13 6.8 141 6 139 165 10.5 0.3 10.9 10.3 09/15/2006 07:50:00 11.1 1 13.7 8.8 11.2 1 14.1 8.8 10.9 1.1 13.7 8 141 7 138 165 10.5 0.2 11.1 10.3 09/15/2006 08:00:00 11.7 0.9 14.1 8.8 11.8 1 14.5 8.8 11.5 0.9 14.1 8.8 141 6 154 165 10.5 0.3 11.1 10.3 09/15/2006 08:10:00 12.6 1 14.5 9.9 12.6 1 14.9 9.9 12.3 1 15.6 9.9 144 6 139 165 10.6 0.2 10.9 10.3 09/15/2006 08:20:00 13.2 1.2 16.1 9.9 13.2 1.2 16.1 9.9 12.7 1.2 15.3 9.5 145 7 145 165 10.7 0.2 11.1 10.3 09/15/2006 08:30:00 12.5 1 15.3 9.9 12.5 0.9 15.3 10.3 12.3 1.1 14.5 8.4 145 6 143 165 10.7 0.1 11.1 10.3 09/15/2006 08:40:00 12.3 1.1 14.5 9.5 12.3 1.1 14.9 9.5 12 1.3 15.3 8.8 144 5 147 165 10.7 0.2 11.1 10.3 09/15/2006 08:50:00 12.4 1.1 15.3 8 12.5 1.1 15.3 8.8 12.2 1.2 15.3 8.8 142 7 147 165 10.7 0.1 11.1 10.3 09/15/2006 09:00:00 13.4 1.1 15.6 10.3 13.5 1.1 15.6 10.3 13.2 1.1 16.1 9.9 143 5 148 165 10.7 0.2 11.1 10.3 09/15/2006 09:10:00 13.9 1.2 17.2 10.3 13.9 1.3 17.2 10.7 13.6 1.3 16.4 10.7 145 11 146 165 10.8 0.1 11.1 10.3 09/15/2006 09:20:00 14.2 1.3 17.2 10.3 14.3 1.3 17.2 10.3 14 1.4 17.2 10.3 144 6 146 165 10.8 0.1 11.1 10.3 09/15/2006 09:30:00 14.1 1 16.4 10.7 14.2 1 16.4 10.7 13.9 1 17.2 11.1 143 5 145 165 10.8 0.1 11.1 10.3 09/15/2006 09:40:00 12.8 1.2 16.1 10.7 12.9 1.2 16.1 9.9 12.7 1.3 16.1 8.8 143 6 147 165 10.8 0.1 11.1 10.6 09/15/2006 09:50:00 13.3 1.2 17.2 10.7 13.5 1.2 17.6 10.3 13 1.2 16.1 9.9 143 7 126 165 10.9 0.1 11.1 10.6 09/15/2006 10:00:00 13.9 1.2 17.2 11.1 14 1.2 17.2 11.1 13.6 1.3 16.4 8.8 145 5 146 165 10.8 0.1 11.1 10.6 09/15/2006 10:10:00 13.4 1.1 16.4 10.7 13.5 1.1 16.8 11.1 13.1 1.3 16.1 8.8 143 6 143 165 10.8 0.1 11.1 10.6 09/15/2006 10:20:00 13.3 1.2 16.1 10.3 13.3 1.1 16.1 10.3 12.9 1.2 15.6 9.5 145 6 150 165 10.8 0.1 11.1 10.3 09/15/2006 10:30:00 14.1 1.3 17.9 9.9 14.1 1.4 17.9 9.9 13.9 1.4 17.2 9.5 144 6 151 165 10.8 0.1 11.1 10.6 09/15/2006 10:40:00 14.9 1.1 17.6 11.8 15 1.1 17.6 11.8 14.6 1.3 17.6 10.7 146 5 158 165 10.7 0.1 11.1 10.3 09/15/2006 10:50:00 15.4 1 18.7 12.2 15.4 1 18.7 12.2 15.3 1.2 18.7 11.5 146 5 148 165 10.8 0.1 11.1 10.6 09/15/2006 11:00:00 15.9 1.1 19.1 13 16 1.1 18.7 13 15.7 1.2 18.7 11.5 144 5 143 165 10.8 0.1 11.1 10.6 09/15/2006 11:10:00 16.1 1 18.7 14.1 16.2 1 19.1 14.1 16 1.1 18.7 12.6 145 4 146 165 10.8 0.1 11.4 10.6 09/15/2006 11:20:00 16.1 1.1 19.9 12.6 16.1 1.2 19.9 12.6 16 1.3 19.5 11.8 145 4 147 165 10.8 0.1 11.1 10.6 09/15/2006 11:30:00 15.5 1 17.6 13 15.6 1 17.9 13.3 15.3 1.1 17.9 12.6 145 4 144 165 10.8 0.1 11.1 10.3 09/15/2006 11:40:00 15.2 0.9 17.6 12.6 15.3 0.9 17.2 12.6 14.8 1 17.2 11.5 147 4 151 165 10.9 0 11.1 10.6 09/15/2006 11:50:00 13.7 0.7 16.1 11.5 13.9 0.7 16.1 11.8 13.4 0.8 15.6 11.1 146 3 154 165 10.9 0 11.1 10.6 09/15/2006 12:00:00 13.3 0.8 15.6 11.1 13.4 0.8 15.6 11.1 12.9 1 14.9 9.5 146 4 148 165 11 0.1 11.1 10.9 09/15/2006 12:10:00 13 0.7 14.5 11.1 13.1 0.7 14.5 11.1 12.7 0.8 14.9 8.4 146 3 151 165 10.9 0.1 11.1 10.9 09/15/2006 12:20:00 13.2 0.9 15.3 11.1 13.3 0.9 15.3 11.1 13 1 15.6 10.3 144 3 144 165 10.9 0.1 11.1 10.6 09/15/2006 12:30:00 13.5 0.6 15.3 11.8 13.6 0.6 15.3 11.8 13.4 0.7 14.9 10.3 145 3 146 165 10.8 0.1 11.1 10.6 09/15/2006 12:40:00 12.9 0.7 14.9 11.1 13 0.7 14.9 11.1 12.7 0.9 14.9 9.9 143 4 145 165 10.8 0.1 11.1 10.6 09/15/2006 12:50:00 12.5 0.7 14.1 10.7 12.6 0.7 14.1 10.7 12.1 0.9 14.1 9.9 144 4 142 165 10.8 0.1 11.1 10.6 09/15/2006 13:00:00 12 0.6 13.7 10.3 12.2 0.7 14.1 10.3 11.9 0.8 14.1 8.4 143 5 152 165 10.8 0.1 11.1 10.6 09/15/2006 13:10:00 12 0.6 13.7 9.9 12.1 0.7 13.7 9.5 11.9 0.8 13.7 9.1 143 4 147 165 10.9 0 11.1 10.6 09/15/2006 13:20:00 12.3 0.7 13.7 10.7 12.4 0.7 13.7 10.7 12 0.8 13.7 9.9 145 4 145 165 10.9 0 11.1 10.6 09/15/2006 13:30:00 12.3 0.6 13.7 10.3 12.4 0.6 13.7 10.3 12.1 0.8 13.7 9.9 145 3 143 165 10.9 0 11.1 10.6 09/15/2006 13:40:00 12.4 0.6 14.1 10.7 12.5 0.6 13.7 10.7 12.1 0.9 14.1 8.4 147 4 145 165 10.9 0 11.1 10.6 09/15/2006 13:50:00 11.4 0.7 13.3 9.9 11.5 0.7 13.3 9.9 11.1 0.9 13.7 8.4 145 4 151 165 10.9 0 11.1 10.6 09/15/2006 14:00:00 10.9 0.6 12.2 9.1 11.1 0.6 12.2 9.5 10.7 0.7 12.2 8.8 144 3 145 165 10.9 0 11.1 10.6 09/15/2006 14:10:00 10.6 0.6 12.2 8.8 10.7 0.6 12.2 8.8 10.3 0.7 12.2 8 145 3 144 165 11 0.1 11.4 10.6 09/15/2006 14:20:00 10.9 0.7 13 9.1 10.9 0.7 12.6 9.1 10.4 0.8 12.2 7.6 145 4 148 165 11 0.1 11.1 10.9 09/15/2006 14:30:00 9.9 0.6 11.5 8.4 9.9 0.6 11.5 8.4 9.4 0.8 11.5 6.5 144 5 143 165 11 0.1 11.1 10.9 09/15/2006 14:40:00 10.1 0.5 11.5 8.4 10.1 0.6 11.5 8.8 9.6 0.7 11.1 7.2 142 4 144 165 10.9 0 11.4 10.6 09/15/2006 14:50:00 10 0.5 11.5 8.4 10.2 0.5 11.5 8.4 9.7 0.8 11.5 7.2 142 3 139 165 10.8 0.1 11.1 10.6 09/15/2006 15:00:00 9.8 0.7 11.5 7.2 10 0.7 11.5 7.6 9.5 0.9 11.5 5.7 141 4 142 165 10.7 0.1 11.1 10.3 09/15/2006 15:10:00 9.4 0.7 10.7 7.2 9.5 0.7 11.1 7.2 9.1 0.9 11.5 6.5 138 5 141 165 10.7 0.1 11.1 10.6 09/15/2006 15:20:00 9.9 0.8 12.2 7.2 9.9 0.8 11.8 7.6 9.6 0.8 11.5 6.8 140 5 152 165 10.7 0.1 11.1 10.3 09/15/2006 15:30:00 9.4 0.8 11.8 6.8 9.5 0.8 11.8 7.2 9.2 0.9 11.1 6.1 140 6 143 165 10.7 0.1 11.1 10.6 09/15/2006 15:40:00 9.5 0.5 11.1 8 9.5 0.5 10.7 7.6 9.2 0.7 10.7 6.8 144 3 142 165 10.7 0.1 10.9 10.3 09/15/2006 15:50:00 9.5 0.6 11.1 7.6 9.6 0.6 11.1 8 9.1 0.8 10.7 6.5 144 4 141 165 10.7 0.1 10.9 10.3 09/15/2006 16:00:00 9.5 0.7 11.1 7.2 9.6 0.7 11.5 6.8 9.2 0.8 10.7 6.5 143 4 143 165 10.6 0.1 11.1 10.3 09/15/2006 16:10:00 9.5 0.6 11.1 8 9.6 0.6 11.1 8 9.1 0.7 10.3 7.2 146 4 147 165 10.6 0.2 10.9 10.3 09/15/2006 16:20:00 9.1 0.6 10.7 7.2 9.1 0.6 10.7 7.6 8.8 0.6 10.3 6.8 146 4 147 165 10.6 0.1 10.9 10.3 09/15/2006 16:30:00 9.1 0.8 10.7 6.8 9.2 0.8 11.1 7.2 8.9 0.9 10.7 6.1 147 3 148 165 10.6 0.1 10.9 10.3 09/15/2006 16:40:00 8.4 0.7 9.9 6.5 8.4 0.7 10.3 6.1 8.2 0.7 10.3 6.1 145 4 142 165 10.5 0.2 10.9 10.3 09/15/2006 16:50:00 9.4 0.6 11.1 7.6 9.4 0.6 11.5 7.6 9.1 0.7 11.1 6.8 142 3 141 165 10.5 0.3 10.9 10.3 09/15/2006 17:00:00 8.9 0.5 9.9 7.2 9 0.5 10.3 7.2 8.7 0.5 9.9 6.8 142 3 142 165 10.5 0.3 10.9 10.3 09/15/2006 17:10:00 8.1 0.6 9.5 6.8 8.1 0.6 10.3 6.8 8 0.6 9.5 6.1 142 4 133 165 10.5 0.3 11.1 10.3 09/15/2006 17:20:00 6.9 0.5 8 5.3 6.9 0.4 8 5.7 6.8 0.5 8 5.3 144 5 148 165 10.5 0.3 10.9 10.3 09/15/2006 17:30:00 6.3 0.6 7.6 4.6 6.3 0.5 7.2 4.9 6.3 0.5 7.6 4.9 148 5 145 165 10.5 0.3 10.9 9.8 09/15/2006 17:40:00 6.3 0.6 8.4 4.9 6.3 0.5 8 4.9 6.4 0.6 8.8 4.9 156 5 162 165 10.5 0.3 10.9 10.1 09/15/2006 17:50:00 8.2 0.6 9.9 6.1 8 0.6 9.5 6.5 8.4 0.6 10.3 6.5 160 7 160 165 10.5 0.3 10.9 10.1 09/15/2006 18:00:00 8.9 1.3 11.8 6.1 8.7 1.3 11.5 6.1 9.1 1.2 11.8 6.5 162 6 166 165 10.5 0.3 10.9 9.8 09/15/2006 18:10:00 10.9 1.1 13.3 8 10.7 1 13 8 10.9 1.1 13.7 7.2 167 13 166 165 10.4 0.3 11.1 9.8 09/15/2006 18:20:00 11.1 0.6 12.6 8.8 10.7 0.6 11.8 8.4 11.1 0.7 12.6 8.8 172 10 165 165 10.4 0.2 10.9 9.8 09/15/2006 18:30:00 11 0.7 12.2 9.1 10.7 0.7 11.8 9.1 11.2 0.8 13 9.1 171 5 177 165 10.5 0.2 10.9 9.8 09/15/2006 18:40:00 10.7 0.6 12.2 8.8 10.4 0.6 11.8 8.8 10.7 0.7 12.2 8.8 170 4 166 165 10.4 0.1 10.9 9.8 09/15/2006 18:50:00 10 0.6 11.5 8.4 9.8 0.6 11.1 7.6 10.2 0.7 12.2 8 169 7 170 165 10.4 0 10.9 9.8 09/15/2006 19:00:00 8.3 0.5 9.5 6.8 8.2 0.5 9.5 6.8 8.5 0.6 10.3 6.8 158 6 153 165 10.3 0 10.6 9.8 09/15/2006 19:10:00 8.7 0.7 10.3 6.8 8.6 0.7 10.7 6.8 9 0.7 10.7 7.6 157 5 157 165 10.4 0 10.6 9.8 09/15/2006 19:20:00 8.4 0.7 9.9 6.8 8.3 0.6 9.9 6.8 8.6 0.6 10.3 6.8 162 10 106 165 10.4 0 10.6 10.3 09/15/2006 19:30:00 8 0.6 9.9 6.5 7.9 0.6 9.5 6.5 8.1 0.5 9.9 6.8 156 5 154 165 10.4 0 10.6 9.8 09/15/2006 19:40:00 7.9 0.4 9.1 6.8 7.8 0.4 8.8 6.8 8 0.4 9.1 6.8 156 3 157 165 10.4 0 10.9 9.8 09/15/2006 19:50:00 7.6 0.6 8.8 6.1 7.6 0.5 8.8 5.7 7.7 0.5 8.8 6.1 158 4 159 165 10.3 0 10.9 10.3 09/15/2006 20:00:00 7.6 0.6 9.1 6.1 7.5 0.6 8.8 6.1 7.7 0.6 9.1 6.1 155 4 158 165 10.3 0 10.6 10.1 09/15/2006 20:10:00 7.5 0.5 8.8 6.1 7.4 0.5 8.8 6.1 7.7 0.5 9.1 6.5 158 6 154 165 10.3 0 10.6 9.8 09/15/2006 20:20:00 7.1 0.5 8.4 5.7 7 0.5 8.4 5.7 7.4 0.5 8.8 5.7 159 4 159 165 10.3 0 10.6 9.8 09/15/2006 20:30:00 6.8 0.6 8.4 5.3 6.7 0.6 8.4 5.3 6.9 0.6 8.4 5.3 161 12 160 165 10.3 0 10.6 9.8 09/15/2006 20:40:00 6.6 0.5 8 4.9 6.6 0.5 8 4.9 6.7 0.5 8.4 5.7 161 5 159 165 10.4 0 10.6 9.8 09/15/2006 20:50:00 7.1 0.5 8.4 5.7 7 0.5 8 5.3 7.3 0.6 8.4 5.3 164 10 164 165 10.3 0 10.9 9.8 09/15/2006 21:00:00 7.8 0.8 9.9 6.1 7.5 0.7 9.5 6.1 8 0.8 9.9 6.5 167 10 173 165 10.3 0 10.6 10.1 09/15/2006 21:10:00 9.3 0.8 10.7 6.5 9 0.7 10.7 6.5 9.5 0.8 11.1 6.8 168 8 175 165 10.2 0 10.6 9.8 09/15/2006 21:20:00 9.7 0.5 11.1 8.4 9.4 0.4 10.7 8 9.9 0.5 11.5 8.4 167 11 173 165 10.2 0 10.6 9.8 09/15/2006 21:30:00 9.7 0.7 11.5 8.4 9.4 0.6 11.1 8 9.9 0.7 11.8 8 168 12 171 165 10.2 0 10.6 9.8 09/15/2006 21:40:00 10 0.4 11.5 8.8 9.7 0.4 10.7 8.4 10.2 0.5 11.5 8.8 165 10 169 165 10.2 0 10.6 9.8 09/15/2006 21:50:00 8.8 1 10.7 5.7 8.6 0.9 10.7 6.1 8.9 1 11.5 6.1 162 4 165 165 10.1 0 10.3 9.8 09/15/2006 22:00:00 7.4 0.7 9.1 5.7 7.3 0.7 9.5 5.7 7.6 0.7 9.9 6.1 157 6 164 165 10.1 0 10.3 9.8 09/15/2006 22:10:00 7.7 0.9 10.7 5.7 7.5 0.8 9.9 6.1 7.9 0.8 10.3 6.5 156 9 156 165 10.1 0 10.3 9.8 09/15/2006 22:20:00 8.4 0.8 10.3 5.7 8.3 0.8 10.3 5.7 8.7 0.7 10.7 6.8 158 10 164 165 10.1 0 10.3 9.8 09/15/2006 22:30:00 8.1 0.7 9.9 5.7 7.9 0.6 9.5 6.1 8.2 0.7 10.3 6.1 166 15 166 165 10 0 10.6 9.6 09/15/2006 22:40:00 9.1 1 11.5 6.8 8.9 1 10.7 6.8 9.2 1.1 11.5 7.2 170 7 177 165 10 0 10.3 9.6 09/15/2006 22:50:00 9.3 0.6 10.7 7.6 9.2 0.6 10.7 7.2 9.3 0.8 11.1 6.8 169 8 173 165 10 0 10.3 9.6 09/15/2006 23:00:00 8.4 0.5 9.9 6.8 8.3 0.5 10.3 6.8 8.4 0.7 9.9 6.5 166 5 162 165 10 0 10.1 9.6 09/15/2006 23:10:00 8.7 0.7 10.7 6.1 8.6 0.7 10.3 5.7 8.8 0.7 10.3 6.5 166 8 165 165 9.9 0 10.3 9.6 09/15/2006 23:20:00 7.1 0.9 9.5 4.9 6.9 0.9 9.5 4.9 7.1 1 9.5 5.3 165 5 160 165 9.9 0 10.3 9.6 09/15/2006 23:30:00 6.3 0.5 7.2 4.9 6.1 0.4 7.2 4.9 6.4 0.5 7.6 4.9 164 18 162 165 9.9 0 10.6 9.6 09/15/2006 23:40:00 5.8 0.5 6.8 4.2 5.6 0.4 6.8 4.2 6 0.4 7.2 4.9 160 6 163 165 10 0 10.6 9.6 09/15/2006 23:50:00 4.9 0.6 6.8 3.4 4.7 0.6 6.1 3.4 5.2 0.6 6.8 3.8 163 9 158 165 10 0 10.3 9.8 09/16/2006 00:00:00 4.7 0.6 5.7 3.4 4.5 0.6 5.7 3 4.9 0.6 6.1 3.4 166 9 162 165 10 0 10.3 9.8 09/16/2006 00:10:00 4.2 0.6 6.1 3 4 0.6 5.7 2.6 4.5 0.5 6.1 3.4 161 10 165 165 10 0 10.3 9.6 09/16/2006 00:20:00 4.2 0.5 5.7 3 4.1 0.5 5.3 3 4.6 0.5 6.1 3 156 10 155 165 10 0 10.3 9.6 09/16/2006 00:30:00 4.6 0.7 6.8 3 4.5 0.6 6.5 3 4.8 0.6 7.2 3.4 162 8 171 165 10 0 10.3 9.6 09/16/2006 00:40:00 4.6 0.5 5.7 3 4.4 0.5 5.7 3 4.8 0.6 6.1 3.4 167 6 166 165 9.9 0 10.3 9.6 09/16/2006 00:50:00 4.2 0.7 5.7 2.6 4 0.6 5.3 2.6 4.4 0.7 6.1 3 169 13 167 165 9.8 0 10.3 9.6 09/16/2006 01:00:00 3.5 0.7 5.7 1.9 3.4 0.7 5.3 1.9 3.8 0.7 6.1 2.3 174 11 179 165 9.8 0 10.1 9.6 09/16/2006 01:10:00 2.2 0.7 3.4 0.7 2.1 0.6 3.4 0.4 2.6 0.6 3.8 1.1 172 7 173 165 9.7 0 10.3 9.3 09/16/2006 01:20:00 0.8 0.3 1.5 0.4 0.8 0.3 1.9 0.4 1.6 0.4 2.3 0.7 164 5 161 165 9.6 0 9.8 9.3 09/16/2006 01:30:00 1 0.4 1.9 0.4 1 0.4 1.9 0.4 1.6 0.5 2.3 0.4 167 7 162 165 9.6 0 9.8 9.3 09/16/2006 01:40:00 0.6 0.4 1.5 0.4 0.5 0.3 1.1 0.4 0.9 0.5 1.9 0.4 174 3 172 165 9.6 0 9.8 9.3 09/16/2006 01:50:00 1.6 0.3 2.3 1.1 1.4 0.3 2.3 0.7 1.8 0.2 2.3 1.5 169 4 177 165 9.6 0 9.8 9.3 09/16/2006 02:00:00 1.8 0.3 2.6 1.1 1.7 0.3 2.3 1.1 2.2 0.3 2.6 1.5 161 10 160 165 9.6 0.1 9.8 9 09/16/2006 02:10:00 2.1 0.4 3.4 1.1 1.9 0.4 3 1.1 2.4 0.2 2.6 1.9 164 6 165 165 9.6 0 9.6 9 09/16/2006 02:20:00 3 0.3 3.8 2.3 2.8 0.3 3.8 1.9 3 0.3 3.8 2.3 162 3 163 165 9.6 0.1 9.6 9 09/16/2006 02:30:00 3.1 0.2 3.4 2.6 2.9 0.2 3.4 2.6 3.2 0.2 3.8 2.6 167 5 160 165 9.6 0 9.6 9 09/16/2006 02:40:00 3.2 0.2 3.4 2.6 3 0.2 3.4 2.3 3.2 0.3 3.8 2.3 173 6 170 165 9.6 0 9.6 9 09/16/2006 02:50:00 2.7 0.3 3.4 2.3 2.6 0.3 3.4 2.3 2.9 0.3 3.8 1.9 175 3 162 165 9.6 0.1 9.6 9 09/16/2006 03:00:00 4.4 0.5 4.9 3 4.1 0.5 4.6 3 4.5 0.4 5.3 3.4 174 3 178 165 9.5 0.1 9.6 9 09/16/2006 03:10:00 2.4 0.5 3.4 1.5 2.4 0.4 3.4 1.5 2.4 0.5 3.8 1.1 196 11 176 165 9.3 0.1 9.6 8.8 09/16/2006 03:20:00 2.1 0.3 2.6 1.5 2.1 0.3 2.6 1.5 2.5 0.3 3.4 1.5 214 8 212 165 9.2 0.1 9.6 8.5 09/16/2006 03:30:00 2.6 0.5 3.4 1.9 2.5 0.4 3.4 1.9 2.8 0.4 3.8 2.3 189 6 183 165 9.3 0 9.6 8.8 09/16/2006 03:40:00 3.3 0.2 3.8 3 3.2 0.2 3.8 2.6 3.6 0.2 4.2 3.4 186 1 186 165 9.2 0 9.3 8.8 09/16/2006 03:50:00 3.1 0.2 3.4 2.6 3 0.2 3.4 2.6 3.5 0.2 3.8 3 185 2 186 165 9.2 0.1 9.6 8.8 09/16/2006 04:00:00 3.7 0.5 4.9 2.6 3.6 0.5 4.6 2.6 4.1 0.4 4.6 3 183 2 182 165 9.2 0.1 9.3 8.8 09/16/2006 04:10:00 1.8 0.8 3.8 0.4 1.7 0.8 3.4 0.4 2.1 0.9 4.2 0.7 172 22 181 165 9 0.2 9.3 8.5 09/16/2006 04:20:00 0.9 0.5 1.9 0.4 0.8 0.4 1.9 0.4 1.3 0.4 2.3 0.4 194 15 197 165 9.2 0 9.6 8.8 09/16/2006 04:30:00 1.5 0.7 2.6 0.4 1.3 0.7 2.6 0.4 1.8 0.7 3 0.4 168 3 165 165 9.2 0.1 9.6 8.8 09/16/2006 04:40:00 0.5 0.2 1.1 0.4 0.4 0 0.4 0.4 0.8 0.5 1.5 0.4 167 1 167 165 9.2 0.1 9.6 8.8 09/16/2006 04:50:00 1 0.4 1.9 0.4 0.8 0.4 1.9 0.4 1.3 0.5 2.3 0.4 167 5 172 165 9.4 0.1 9.6 9 09/16/2006 05:00:00 2 0.4 3 1.1 1.8 0.4 2.6 1.1 2.2 0.3 3 1.9 166 6 169 165 9.4 0.2 9.6 8.8 09/16/2006 05:10:00 2.1 0.6 4.6 0.7 1.9 0.6 4.6 0.4 2.3 0.5 4.6 1.1 162 14 138 165 9.4 0.2 9.8 8.8 09/16/2006 05:20:00 2.1 1.5 4.9 0.4 2.1 1.6 5.3 0.4 2.2 1.5 4.9 0.4 144 22 121 165 9.3 0.1 9.6 8.8 09/16/2006 05:30:00 2.1 0.8 4.2 0.4 1.9 0.9 4.2 0.4 2.4 0.8 4.2 0.4 141 19 121 165 9.3 0 9.6 8.8 09/16/2006 05:40:00 1.9 0.7 3 0.4 1.8 0.7 3 0.4 2.2 0.5 3.4 1.5 133 17 156 165 9.4 0 9.6 9 09/16/2006 05:50:00 2.7 0.3 3.4 1.9 2.6 0.3 3.4 1.9 2.8 0.3 3.4 2.3 151 5 144 165 9.5 0 9.8 9 09/16/2006 06:00:00 2.4 0.9 3.8 0.4 2.3 0.9 3.8 0.4 2.7 0.9 4.2 0.4 136 35 99 165 9.5 0.1 9.6 9 09/16/2006 06:10:00 1.1 0.5 2.3 0.4 1 0.5 2.3 0.4 1.2 0.6 2.6 0.4 134 24 139 165 9.4 0 9.6 9 09/16/2006 06:20:00 0.6 0.5 1.9 0.4 0.6 0.5 2.3 0.4 0.7 0.5 1.9 0.4 123 76 115 165 9.2 0.1 9.6 8.8 09/16/2006 06:30:00 0.4 0.2 1.1 0.4 0.4 0.1 0.7 0.4 0.7 0.4 1.5 0.4 29 64 87 165 9 0.2 9.3 8.5 09/16/2006 06:40:00 1.5 0.6 2.6 0.4 1.5 0.6 2.6 0.4 1.5 0.6 2.6 0.4 102 9 111 165 9.2 0.1 9.3 8.5 09/16/2006 06:50:00 1.9 0.6 3 1.1 1.9 0.7 3 1.1 2.2 0.6 3.4 1.1 101 3 104 165 9.3 0 9.6 8.8 09/16/2006 07:00:00 1.2 0.3 1.9 0.7 1 0.4 1.9 0.4 0.9 0.6 2.3 0.4 100 2 106 165 9.3 0 9.6 8.8 09/16/2006 07:10:00 0.5 0.3 1.9 0.4 0.4 0.2 1.5 0.4 0.6 0.3 1.1 0.4 63 22 102 165 9.2 0 9.3 8.8 09/16/2006 07:20:00 0.7 0.5 2.6 0.4 0.6 0.5 2.3 0.4 1.1 0.6 2.6 0.4 75 17 70 165 9.2 0 9.6 8.8 09/16/2006 07:30:00 0.8 0.4 1.5 0.4 0.6 0.3 1.5 0.4 1 0.5 1.9 0.4 69 26 84 165 9.4 0.1 9.6 9 09/16/2006 07:40:00 1 0.6 2.3 0.4 0.9 0.6 2.3 0.4 1.2 0.7 2.6 0.4 74 28 29 165 9.4 0.1 9.6 9 09/16/2006 07:50:00 1.1 0.6 2.3 0.4 1 0.6 1.9 0.4 1.3 0.8 2.3 0.4 65 22 54 165 9.4 0.2 9.6 9 09/16/2006 08:00:00 2.3 0.4 3.4 1.1 2.3 0.5 3.4 1.1 2.3 0.4 3 1.1 68 10 70 165 9.6 0.2 9.8 9 09/16/2006 08:10:00 1.4 0.7 3 0.4 1.1 0.7 3 0.4 1.4 0.7 3 0.4 67 8 74 165 9.8 0 10.1 9.3 09/16/2006 08:20:00 1.7 0.6 2.6 0.4 1.5 0.6 2.6 0.4 1.6 0.7 3 0.4 83 11 83 165 10 0 10.1 9.6 09/16/2006 08:30:00 1.9 0.3 2.3 0.7 1.8 0.4 2.6 0.4 2 0.3 2.6 1.1 92 6 88 165 10 0 10.6 9.6 09/16/2006 08:40:00 1.3 0.4 2.3 0.4 1.2 0.5 2.3 0.4 1.5 0.5 2.3 0.4 104 9 98 165 10 0 10.3 9.6 09/16/2006 08:50:00 0.8 0.4 1.9 0.4 0.6 0.3 1.5 0.4 0.9 0.5 1.9 0.4 89 11 85 165 10 0 10.3 9.6 09/16/2006 09:00:00 0.4 0.3 1.5 0.4 0.4 0.2 1.5 0.4 0.5 0.4 1.9 0.4 101 10 125 165 10.3 0 10.6 9.8 09/16/2006 09:10:00 1.3 0.5 2.3 0.4 1.1 0.5 2.3 0.4 1.5 0.4 2.6 0.4 121 5 123 165 10.3 0.2 10.9 9.8 09/16/2006 09:20:00 0.5 0.3 1.9 0.4 0.4 0.2 1.5 0.4 0.6 0.4 2.6 0.4 92 23 118 165 10.5 0.2 10.9 10.1 09/16/2006 09:30:00 0.5 0.3 1.5 0.4 0.4 0.2 1.5 0.4 0.8 0.4 1.9 0.4 346 43 320 165 10.8 0.1 11.1 10.6 09/16/2006 09:40:00 0.8 0.4 1.9 0.4 0.7 0.3 1.5 0.4 1.2 0.5 2.3 0.4 298 13 280 165 10.8 0 11.1 10.6 09/16/2006 09:50:00 0.4 0.2 1.5 0.4 0.4 0 0.7 0.4 0.7 0.4 1.9 0.4 351 6 357 165 11.5 0.2 11.9 10.9 09/16/2006 10:00:00 1.1 0.7 3 0.4 0.9 0.6 3 0.4 1.4 0.7 3 0.4 110 38 139 165 11.7 0 11.9 11.4 09/16/2006 10:10:00 0.8 0.5 2.3 0.4 0.7 0.5 2.3 0.4 1.1 0.6 2.6 0.4 44 32 48 165 11.7 0.1 11.9 11.4 09/16/2006 10:20:00 1.9 0.4 3 0.7 1.8 0.5 3 0.4 2.3 0.4 3 1.1 40 7 33 165 11.1 0.2 11.7 10.6 09/16/2006 10:30:00 1.6 0.4 3 0.4 1.1 0.6 2.6 0.4 2.1 0.3 3 1.1 11 19 16 165 11.1 0.4 11.9 10.3 09/16/2006 10:40:00 2.1 0.4 3.4 1.5 1.6 0.7 3.4 0.4 2.6 0.4 3.4 1.5 10 11 22 165 11.9 0.1 12.2 11.4 09/16/2006 10:50:00 3.7 0.5 4.9 2.6 3.3 0.7 4.9 1.1 3.9 0.5 5.3 2.6 18 7 21 165 12.1 0.5 13 11.1 09/16/2006 11:00:00 4.1 0.5 5.3 2.6 3.9 0.5 5.3 2.3 4.2 0.5 5.7 2.6 21 6 19 165 12.6 0 12.7 12.2 09/16/2006 11:10:00 4.1 0.5 5.7 2.6 3.5 0.7 5.7 1.9 4.3 0.6 5.7 2.6 14 11 32 165 12.9 0.1 13 12.5 09/16/2006 11:20:00 4.9 0.6 6.1 3 4.7 0.6 6.1 2.6 5.1 0.6 6.5 3.4 24 6 22 165 12.7 0.3 13 11.9 09/16/2006 11:30:00 5.6 0.5 6.8 4.2 5.6 0.5 6.8 3.8 5.8 0.5 7.2 4.6 26 4 28 165 11.9 0.1 12.2 11.7 09/16/2006 11:40:00 5.2 0.5 6.5 3.4 4.9 0.7 6.1 3 5.5 0.5 6.8 3.8 21 5 23 165 12 0 12.2 11.9 09/16/2006 11:50:00 4.7 0.3 5.7 3.8 4 0.7 5.7 1.9 5.1 0.4 6.1 3.4 17 6 5 165 11.9 0.1 12.2 11.9 09/16/2006 12:00:00 5.1 0.4 6.5 4.2 4.8 0.6 5.7 2.6 5.3 0.5 6.5 3.4 21 6 22 165 11.9 0.1 12.2 11.7 09/16/2006 12:10:00 5.4 0.3 6.1 4.6 4 1.1 6.1 1.5 5.7 0.4 6.5 4.6 10 8 14 165 11.4 0 11.7 10.9 09/16/2006 12:20:00 5.6 0.4 6.5 4.6 3.4 0.6 5.7 2.3 5.8 0.4 6.8 4.2 2 6 5 165 11.7 0 11.9 11.4 09/16/2006 12:30:00 5.8 0.6 7.6 4.6 4.2 1.2 7.2 1.9 6.1 0.6 8 4.6 4 10 8 165 11.7 0 11.9 11.7 09/16/2006 12:40:00 6.9 0.5 8.8 5.7 5.9 1.1 8.8 2.6 7.2 0.6 9.1 5.7 14 6 20 165 11.3 0 11.7 11.1 09/16/2006 12:50:00 7.7 0.5 9.1 6.1 7.1 1 8.8 3.4 8 0.6 9.5 6.1 17 5 12 165 10.8 0.2 11.1 10.3 09/16/2006 13:00:00 8.9 0.7 11.1 7.2 8.1 1 11.1 4.9 9 0.8 11.5 6.8 17 5 22 165 10.7 0.1 10.9 10.1 09/16/2006 13:10:00 9.4 0.4 10.3 8 8.3 0.8 10.3 5.3 9.6 0.6 10.7 7.6 14 3 17 165 10.5 0 10.9 10.6 09/16/2006 13:20:00 9.5 0.5 11.5 8.4 7.7 1.2 11.1 4.6 9.7 0.6 11.8 7.6 11 5 20 165 10.7 0 10.9 10.6 09/16/2006 13:30:00 9 0.6 10.3 7.2 7.3 1 9.9 4.6 8.9 0.7 10.7 7.2 11 5 16 165 10.7 0 10.9 10.6 09/16/2006 13:40:00 9.3 0.7 10.7 6.8 8 1.2 10.3 4.9 9.1 0.9 11.1 6.5 13 6 22 165 10.7 0 10.9 10.6 09/16/2006 13:50:00 7.9 0.8 9.9 5.7 6.3 1 8.8 4.2 7.9 0.9 9.9 5.7 8 7 8 165 10.5 0 10.9 10.3 09/16/2006 14:00:00 7.8 1.1 11.1 4.9 6.7 1.2 10.3 3.4 7.8 1.1 11.1 5.3 12 7 5 165 10.5 0 10.9 10.3 09/16/2006 14:10:00 8.2 1.5 11.5 4.9 7.5 1.8 11.5 3.4 8 1.5 12.2 5.3 17 8 15 165 10.5 0 10.9 10.3 09/16/2006 14:20:00 9.6 1.3 13 6.5 9 1.5 12.6 5.7 9.3 1.4 13 6.1 19 8 23 165 10.3 0.1 10.6 10.3 09/16/2006 14:30:00 10.4 1.2 13.3 7.2 9.8 1.5 13.3 5.7 10.2 1.3 13 6.8 19 8 18 165 10 0 10.3 9.8 09/16/2006 14:40:00 10.3 1.1 12.6 7.2 9.7 1.2 12.6 6.1 10 1.1 13 6.8 19 8 14 165 9.9 0 10.1 9.6 09/16/2006 14:50:00 10.2 1.2 13.3 7.2 9.8 1.3 13 6.5 10 1.2 12.6 5.7 20 8 22 165 9.8 0 9.8 9.3 09/16/2006 15:00:00 10.6 1.2 13 7.6 10.2 1.3 13 7.2 10.3 1.1 13.3 7.6 21 7 17 165 9.8 0 9.8 9.6 09/16/2006 15:10:00 10.6 1.3 13.7 7.2 10.1 1.5 13.7 6.1 10.4 1.3 13.7 7.6 21 8 23 165 9.8 0 10.1 9.6 09/16/2006 15:20:00 10.7 1.1 13.3 7.6 10.3 1.3 13.3 6.5 10.5 1.3 13.7 7.2 20 7 27 165 9.8 0 9.8 9.6 09/16/2006 15:30:00 10.7 1.3 14.1 7.2 10.2 1.5 14.1 5.7 10.5 1.4 13.7 6.8 19 8 22 165 9.7 0 9.8 9.6 09/16/2006 15:40:00 10.9 1.1 13.7 7.6 10 1.3 13.3 6.8 10.6 1.2 13.7 7.2 16 8 6 165 9.8 0 9.8 9.6 09/16/2006 15:50:00 11.2 1.4 14.5 8 10.1 1.7 14.5 5.7 10.9 1.4 14.9 7.2 16 6 18 165 9.8 0 9.8 9.6 09/16/2006 16:00:00 11.1 1.3 14.5 7.2 10.1 1.7 14.1 6.1 10.8 1.4 14.1 7.2 16 8 22 165 9.7 0 9.8 9.6 09/16/2006 16:10:00 11.1 1.7 14.9 7.2 9.1 1.7 13.3 5.3 11.1 1.9 14.9 6.5 11 7 16 165 9.8 0 10.1 9.3 09/16/2006 16:20:00 10.6 1.3 13.7 7.2 7.9 1.2 12.2 4.9 10.5 1.3 13.7 6.5 5 8 4 165 9.8 0 10.1 9.3 09/16/2006 16:30:00 11.5 1.4 16.1 8 9.2 1.7 14.1 6.1 11.2 1.5 16.4 7.2 9 8 8 165 9.8 0 10.1 9.3 09/16/2006 16:40:00 11.5 1.5 16.1 7.6 8.9 1.7 14.5 5.3 11.6 1.5 16.1 8 7 7 12 165 9.7 0.1 9.8 9.3 09/16/2006 16:50:00 11.9 1.4 15.6 8 9.3 1.6 14.5 6.1 11.9 1.5 15.6 8 8 8 12 165 9.6 0.1 9.8 9.3 09/16/2006 17:00:00 13.2 1.6 17.2 9.5 10.4 1.7 14.9 6.8 12.9 1.6 17.2 8.8 9 8 21 165 9.6 0.1 9.8 9.3 09/16/2006 17:10:00 13 1.6 16.4 9.1 10.1 1.7 16.1 6.8 12.6 1.6 16.1 8.4 7 7 3 165 9.6 0.1 10.1 9.3 09/16/2006 17:20:00 13.2 1.5 17.6 9.1 10.5 1.7 16.4 5.7 12.9 1.5 16.8 8 9 9 11 165 9.6 0.2 9.8 9 09/16/2006 17:30:00 13.7 1.7 18.7 9.1 10.3 1.7 16.4 6.8 13.5 1.7 19.1 9.5 6 7 10 165 9.6 0.2 9.8 9.3 09/16/2006 17:40:00 12.8 1.6 17.6 9.5 10.4 1.7 14.9 6.8 12.7 1.6 17.2 8.4 10 7 9 165 9.6 0.2 10.1 9 09/16/2006 17:50:00 12.6 1.5 16.4 8 10.4 1.8 15.3 6.5 12.3 1.5 16.8 8 11 8 9 165 9.6 0.2 9.8 9 09/16/2006 18:00:00 13.1 1.5 16.4 8.8 11.5 1.9 16.1 6.8 12.7 1.5 16.8 9.1 15 8 16 165 9.6 0.2 9.8 9 09/16/2006 18:10:00 13 1.5 18.3 9.9 11.1 1.8 16.4 6.8 12.8 1.5 17.2 8 13 8 18 165 9.6 0.2 9.8 9 09/16/2006 18:20:00 12 1.5 16.4 8.8 9.9 1.7 15.3 6.1 11.9 1.5 16.1 8 11 8 5 165 9.6 0.1 9.8 9 09/16/2006 18:30:00 13.3 1.6 17.2 9.5 10.1 1.7 15.6 6.8 13.2 1.6 17.2 9.1 8 7 5 165 9.6 0 9.8 9 09/16/2006 18:40:00 12.8 1.6 17.2 8.8 10.4 1.6 15.3 6.1 12.7 1.7 17.9 8.4 11 8 4 165 9.5 0 9.8 9 09/16/2006 18:50:00 13.2 1.7 17.2 9.1 10.5 2 16.8 6.5 13.1 1.7 17.2 9.1 10 7 18 165 9.4 0 9.6 9 09/16/2006 19:00:00 13.6 1.6 18.3 9.9 10.4 1.8 16.1 6.5 13.7 1.5 18.7 9.5 9 6 12 165 9.2 0 9.6 9 09/16/2006 19:10:00 13.1 1.6 17.2 8.8 9.8 1.7 15.3 6.5 12.9 1.7 17.9 9.1 7 9 9 165 9.2 0 9.6 9 09/16/2006 19:20:00 11.4 1.4 16.8 9.1 8.5 1.5 14.1 5.7 11.4 1.4 16.1 8.4 6 8 7 165 9.2 0 9.3 9 09/16/2006 19:30:00 13.6 1.8 17.6 9.5 10 1.9 15.3 6.1 13.5 1.9 17.9 9.5 6 7 14 165 9.3 0 9.3 9 09/16/2006 19:40:00 13.8 1.6 17.2 9.1 9.9 1.6 14.5 6.1 13.7 1.7 17.6 8.8 7 6 3 165 9.4 0 9.6 9 09/16/2006 19:50:00 12.4 1.5 15.6 8.8 9.2 1.5 14.1 6.1 12.5 1.3 15.3 8.8 6 7 18 165 9.5 0 9.8 9 09/16/2006 20:00:00 12.6 1.4 16.1 8.4 9.5 1.7 14.9 6.1 12.5 1.3 16.1 9.1 7 8 18 165 9.6 0.1 9.6 9.3 09/16/2006 20:10:00 11.6 1.5 16.4 8 9.1 1.7 14.5 5.3 11.4 1.7 16.4 7.6 9 8 13 165 9.6 0 9.8 9.6 09/16/2006 20:20:00 9.8 1.5 14.5 6.1 8.3 1.4 11.8 5.3 9.6 1.4 13.7 6.5 13 8 11 165 9.7 0 9.8 9.6 09/16/2006 20:30:00 9.4 1.4 13.3 6.1 8.8 1.5 12.6 5.3 9.2 1.4 13 5.7 20 8 18 165 9.8 0 9.8 9.6 09/16/2006 20:40:00 7.5 1 9.9 5.3 7.4 1 9.9 4.2 7.4 1 9.9 4.6 29 9 20 165 9.8 0 10.3 9.6 09/16/2006 20:50:00 7.9 0.9 9.9 5.3 7.8 0.9 10.3 5.3 7.9 0.9 9.9 5.3 33 7 15 165 9.9 0 10.1 9.6 09/16/2006 21:00:00 7 0.8 9.1 4.6 7 0.8 9.1 4.6 7 0.8 8.8 4.6 36 6 25 165 9.9 0 10.1 9.6 09/16/2006 21:10:00 5.9 0.8 7.6 3.8 5.9 0.8 7.6 3.8 5.9 0.7 8 4.2 41 6 36 165 10 0 10.6 9.6 09/16/2006 21:20:00 5.4 0.7 7.2 3.8 5.4 0.7 6.8 3.8 5.5 0.7 7.2 3.8 41 7 37 165 10 0 10.3 9.6 09/16/2006 21:30:00 5 0.8 7.2 3 5 0.8 7.2 3 5.1 0.8 6.8 3 44 7 41 165 10.1 0 10.3 9.6 09/16/2006 21:40:00 4.1 0.9 6.1 1.9 4.1 0.9 6.1 1.9 4.3 0.8 6.1 2.6 47 9 48 165 10.1 0 10.6 9.8 09/16/2006 21:50:00 4.1 1.1 8 1.9 4.1 1.1 8 1.9 4.2 1 7.6 2.3 49 12 39 165 10.1 0 10.3 9.6 09/16/2006 22:00:00 5.1 1.1 8.8 2.6 5.1 1.2 9.1 2.6 5.1 1.1 9.1 3 44 12 47 165 10.1 0 10.3 9.8 09/16/2006 22:10:00 6.2 1.5 9.5 3 6.2 1.7 9.9 3 6 1.4 9.5 3 53 11 49 165 10.1 0 10.3 9.8 09/16/2006 22:20:00 8 1.9 12.2 3.4 8.1 1.9 12.6 3.8 7.7 1.6 11.1 3.8 63 11 54 165 10.1 0 10.3 10.1 09/16/2006 22:30:00 7.4 1.6 12.2 4.2 7.5 1.7 12.6 4.6 7.1 1.4 11.8 4.2 57 12 55 165 10.1 0 10.3 9.8 09/16/2006 22:40:00 8.9 2.2 13.3 3.4 9 2.3 14.1 3.8 8.7 2.1 13.3 4.2 57 11 62 165 9.8 0 10.1 9.6 09/16/2006 22:50:00 8.5 1.7 13.7 4.2 8.6 1.7 13.3 4.6 8.2 1.8 13.7 4.6 55 12 61 165 9.6 0 10.3 9.3 09/16/2006 23:00:00 8.1 1.6 12.2 3 8.1 1.7 12.2 3.8 7.9 1.7 12.6 4.2 48 12 45 165 9.5 0.1 9.6 9 09/16/2006 23:10:00 7.9 1.5 11.1 3.8 8 1.6 11.5 3.8 7.9 1.4 11.1 3.8 44 13 56 165 9.3 0 9.6 9 09/16/2006 23:20:00 8 1.8 12.6 4.2 8.1 1.8 12.6 3.8 8 1.7 11.8 3.8 42 12 39 165 9.1 0.1 9.3 8.8 09/16/2006 23:30:00 8.2 1.7 13 4.9 8.3 1.7 13.3 4.9 7.9 1.6 13 4.6 41 11 48 165 9 0.1 9.3 8.8 09/16/2006 23:40:00 8.2 1.5 12.6 4.2 8.2 1.5 12.6 4.2 8 1.5 11.5 4.2 41 11 55 165 9 0 9.3 8.8 09/16/2006 23:50:00 7.7 1.2 11.8 4.9 7.7 1.3 11.8 3.8 7.7 1.2 10.7 4.9 33 10 60 165 9.1 0 9.3 8.5 09/17/2006 00:00:00 8.1 1.2 10.7 4.6 8 1.3 10.7 4.6 7.9 1.2 10.7 4.9 28 8 32 165 9.3 0 9.6 8.8 09/17/2006 00:10:00 8.4 1.2 11.1 5.3 8.3 1.3 11.1 4.9 8.3 1.2 11.1 4.9 30 7 37 165 9.3 0 9.6 9 09/17/2006 00:20:00 8.3 1.2 10.7 5.3 8.2 1.2 11.1 4.9 8.3 1.2 11.5 5.3 27 8 33 165 9.2 0 9.3 9 09/17/2006 00:30:00 8.4 1.3 11.5 4.9 8.3 1.4 11.5 4.9 8 1.2 11.5 4.9 28 9 31 165 9.1 0 9.3 8.8 09/17/2006 00:40:00 8.4 1.4 11.8 5.3 8.2 1.4 11.8 5.3 8.4 1.2 11.5 5.7 27 8 28 165 9.1 0.1 9.3 8.8 09/17/2006 00:50:00 8.6 1.5 11.8 4.9 8.5 1.5 11.8 4.9 8.4 1.5 12.2 4.9 28 9 25 165 9 0.1 9.3 8.5 09/17/2006 01:00:00 9.3 1.7 13 5.3 9.1 1.7 13 4.6 9.1 1.7 13.7 4.9 25 8 16 165 9.1 0 9.3 8.8 09/17/2006 01:10:00 7.6 1.3 11.1 4.6 7.4 1.3 10.7 4.2 7.5 1.2 11.1 4.6 27 10 39 165 9.2 0 9.3 8.8 09/17/2006 01:20:00 8.5 1.3 11.8 4.9 8.2 1.5 11.5 4.6 8.4 1.3 11.5 5.3 23 9 22 165 9.2 0 9.3 8.8 09/17/2006 01:30:00 9.4 1.4 13 5.3 9.1 1.4 13 5.3 9 1.4 13 5.3 26 10 29 165 9.1 0 9.3 8.8 09/17/2006 01:40:00 10.6 1.3 14.5 7.2 10 1.5 13.7 4.2 10.2 1.4 14.1 6.8 19 9 22 165 9 0.1 9.3 8.5 09/17/2006 01:50:00 9.4 1.3 13.3 5.7 8.4 1.6 13 4.9 9.4 1.4 13.7 5.3 15 9 12 165 8.9 0 9 8.5 09/17/2006 02:00:00 8.9 1.3 12.2 5.3 8.5 1.3 12.2 5.3 8.6 1.3 12.6 5.3 23 9 13 165 8.9 0 9 8.5 09/17/2006 02:10:00 8.1 1.5 11.8 4.6 7.8 1.4 11.8 4.6 7.9 1.3 12.6 4.6 24 9 20 165 9 0.1 9.3 8.5 09/17/2006 02:20:00 7.5 1.5 11.1 4.2 7.3 1.5 11.1 3.8 7.6 1.5 11.1 4.6 24 9 26 165 9.1 0 9.3 8.8 09/17/2006 02:30:00 7.7 1.7 11.8 3.8 7.3 1.7 11.5 3.8 7.4 1.5 11.1 4.6 20 10 20 165 9.3 0.1 9.6 8.8 09/17/2006 02:40:00 10.3 1.9 14.9 5.7 9.6 2 14.9 5.7 9.8 1.9 15.3 6.1 18 9 28 165 9.4 0.2 9.6 9 09/17/2006 02:50:00 11.2 1.9 15.3 6.1 9.8 2 14.9 5.3 10.8 1.9 16.1 6.8 13 9 16 165 9.5 0.2 9.8 9 09/17/2006 03:00:00 10.2 1.5 14.9 5.3 8.8 1.6 14.1 4.9 9.9 1.5 14.5 6.5 11 9 16 165 9.6 0.1 9.8 9 09/17/2006 03:10:00 10.8 1.4 15.3 7.2 9.3 1.5 13.7 5.3 10.5 1.5 13.7 6.5 10 8 6 165 9.6 0.1 9.8 9.3 09/17/2006 03:20:00 10.5 1.7 15.3 6.5 9.8 1.9 15.3 5.7 10.1 1.7 14.9 6.5 18 8 8 165 9.6 0.1 9.8 9.3 09/17/2006 03:30:00 10.6 1.5 13.7 6.8 9.4 1.5 13.3 5.7 10.2 1.5 14.5 6.8 13 9 0 165 9.6 0.1 10.1 9 09/17/2006 03:40:00 9.5 1.6 14.1 6.5 8.2 1.7 12.2 4.9 9.2 1.6 13.7 5.7 13 10 6 165 9.5 0.1 9.6 9 09/17/2006 03:50:00 9 1.6 13.7 5.3 8.3 1.7 13 4.6 8.8 1.5 13 5.3 16 10 19 165 9.6 0.1 9.6 9 09/17/2006 04:00:00 9.8 1.8 14.5 5.7 9.1 2 14.5 3.8 9.7 1.9 14.9 5.7 17 9 20 165 9.6 0.1 9.6 9 09/17/2006 04:10:00 10.5 1.6 14.9 6.1 10.1 1.8 14.5 5.3 10.2 1.6 14.5 6.5 21 9 29 165 9.5 0.1 9.6 9 09/17/2006 04:20:00 8.9 1.6 13.3 5.3 8.6 1.7 13.3 4.9 8.9 1.7 13.7 5.3 24 10 35 165 9.4 0.1 9.6 9 09/17/2006 04:30:00 9 1.3 12.2 5.7 8.3 1.5 11.8 4.2 8.6 1.2 11.5 6.1 18 9 19 165 9.4 0 9.6 9 09/17/2006 04:40:00 7.9 1.2 11.1 4.9 7.7 1.3 11.1 4.9 7.7 1.1 11.1 5.3 26 9 29 165 9.4 0 9.6 9 09/17/2006 04:50:00 7.6 1.3 11.1 4.6 6.9 1.4 10.7 3 7.6 1.1 11.5 4.9 16 9 29 165 9.4 0 9.6 9 09/17/2006 05:00:00 8.8 1.2 11.8 5.7 7.2 1.3 10.7 4.2 8.8 1.3 12.6 4.6 11 7 12 165 9.5 0 9.8 9 09/17/2006 05:10:00 9.7 1.2 13 6.5 8.8 1.4 12.2 4.6 9.5 1.3 13 6.5 17 8 16 165 9.5 0 9.6 9 09/17/2006 05:20:00 9.8 1.2 13.3 6.8 8.9 1.5 13 5.3 9.8 1.3 13.3 5.3 16 8 16 165 9.5 0 9.6 9 09/17/2006 05:30:00 10 1.2 13 6.8 8.8 1.7 12.2 4.9 9.8 1.2 12.6 6.8 13 9 15 165 9.5 0 9.6 9 09/17/2006 05:40:00 10.6 1.5 15.6 7.2 8.8 1.5 12.6 4.9 10.2 1.5 15.3 6.5 11 9 9 165 9.4 0 9.6 9 09/17/2006 05:50:00 10.5 1.3 14.1 6.8 8.8 1.5 12.6 4.9 10.5 1.3 13.7 7.2 10 8 19 165 9.4 0 9.6 9 09/17/2006 06:00:00 11.2 1.5 15.6 8 9.6 1.6 13.7 5.7 10.9 1.5 14.9 8 12 9 14 165 9.4 0 9.6 9 09/17/2006 06:10:00 10.7 1.4 13.7 7.6 9 1.3 12.2 4.9 10.6 1.4 14.1 6.8 11 7 8 165 9.4 0 9.6 9 09/17/2006 06:20:00 10.5 1.3 13.7 7.2 8.5 1.4 13.7 4.9 10.4 1.2 13.7 6.8 9 7 11 165 9.4 0 9.6 9 09/17/2006 06:30:00 11.6 1.3 14.9 7.2 9.5 1.5 13.3 5.3 11.4 1.3 14.5 8 11 7 7 165 9.4 0 9.6 9 09/17/2006 06:40:00 10.5 1.6 15.3 6.1 8.7 1.9 13.7 4.9 10.4 1.5 14.5 6.8 10 8 14 165 9.3 0 9.6 8.8 09/17/2006 06:50:00 11.4 1.5 14.9 7.6 9.3 1.7 14.5 5.7 11.3 1.5 16.1 7.2 10 8 10 165 9.2 0 9.6 8.8 09/17/2006 07:00:00 11.3 1.5 14.9 8 9.3 1.6 13.7 5.7 11 1.5 14.9 8 11 8 15 165 9.2 0 9.6 8.8 09/17/2006 07:10:00 11.1 1.5 14.9 8 9.5 1.8 14.9 5.3 10.9 1.6 14.9 7.6 13 7 16 165 9.2 0 9.6 8.8 09/17/2006 07:20:00 11.4 1.4 14.9 7.6 9.1 1.5 13.7 5.3 11.3 1.6 15.3 7.6 9 7 10 165 9.2 0 9.3 8.8 09/17/2006 07:30:00 11.6 1.5 15.3 8.4 9.6 1.6 13.7 6.1 11.5 1.5 15.6 8 11 6 16 165 9.2 0.1 9.6 8.8 09/17/2006 07:40:00 11.8 1.8 17.2 8 9.2 1.7 14.5 5.7 11.9 1.7 17.6 7.6 8 7 10 165 9.2 0 9.3 8.8 09/17/2006 07:50:00 12.1 1.7 16.1 8 10 1.8 15.3 5.3 11.9 1.7 16.1 7.2 11 8 3 165 9.1 0.1 9.3 8.8 09/17/2006 08:00:00 11.8 1.5 16.1 7.6 9.1 1.4 13.3 5.7 11.7 1.5 15.6 7.2 8 7 352 165 9.2 0.1 9.3 8.8 09/17/2006 08:10:00 12.5 1.4 16.4 8.8 10 1.5 14.5 6.1 12.1 1.5 15.6 8.8 9 7 12 165 9 0.1 9.3 8.5 09/17/2006 08:20:00 12.2 1.4 14.9 8 9.5 1.6 13.7 5.3 12 1.6 15.3 7.6 8 8 4 165 9 0.2 9.3 8.5 09/17/2006 08:30:00 12 1.5 16.1 9.1 9.5 1.8 14.9 5.7 12.1 1.5 16.8 8.8 9 8 14 165 9 0.2 9.3 8.5 09/17/2006 08:40:00 11.9 1.3 16.8 8.4 9.6 1.7 16.4 6.1 11.9 1.4 16.8 8.4 10 7 16 165 9 0.2 9 8.5 09/17/2006 08:50:00 12.6 1.3 15.3 9.1 10.1 1.7 14.5 6.5 12.5 1.5 15.6 7.6 11 8 11 165 9 0.2 9 8.5 09/17/2006 09:00:00 10.8 1.2 14.5 8 8.6 1.7 13.7 5.3 10.7 1.3 14.5 6.8 8 9 350 165 9 0.1 9.3 8.5 09/17/2006 09:10:00 11.1 1.4 14.5 8 9.1 2 14.1 5.3 11.1 1.5 15.3 7.2 10 7 30 165 9 0.1 9 8.5 09/17/2006 09:20:00 10.8 1.3 13.7 8 8.4 1.7 13.3 5.3 10.8 1.4 14.1 7.2 8 7 11 165 9 0.1 9.3 8.5 09/17/2006 09:30:00 10.8 1.4 14.1 7.6 8.5 1.7 13 4.9 10.7 1.4 14.9 6.8 9 8 18 165 9 0.1 9.3 8.5 09/17/2006 09:40:00 10.8 1.6 15.3 7.2 8.2 1.9 13 4.6 10.7 1.5 15.6 7.2 5 8 13 165 9.2 0 9.3 8.8 09/17/2006 09:50:00 9.9 1 12.6 6.8 8 1.5 11.8 4.6 9.6 1 13 6.8 11 8 28 165 9.3 0 9.6 9 09/17/2006 10:00:00 9.7 0.9 12.2 7.2 7.7 1.5 11.8 4.6 9.7 1 12.2 7.2 6 9 7 165 9.4 0 9.8 8.8 09/17/2006 10:10:00 9.4 1.2 13 6.8 7.3 1.2 10.7 4.6 9.6 1.1 13 7.6 6 8 358 165 9.4 0 9.6 9 09/17/2006 10:20:00 9 1 11.8 6.1 6.8 1.2 10.3 3.8 8.8 1 11.5 4.2 3 8 1 165 9.5 0 9.6 9 09/17/2006 10:30:00 9.1 1 11.5 6.1 7.7 1.6 11.1 4.6 9.1 1.1 11.8 6.8 12 8 359 165 9.5 0 9.6 9 09/17/2006 10:40:00 9.7 1 13 7.2 7.9 1.5 13 4.9 9.7 1.2 13.3 6.8 11 7 20 165 9.4 0 9.6 9 09/17/2006 10:50:00 9.4 1 12.2 6.5 7.5 1.5 11.1 4.2 9.5 1 12.6 6.8 11 6 10 165 9.4 0 9.6 9 09/17/2006 11:00:00 9.2 1.2 13.3 6.1 7.5 1.7 12.6 4.6 9.4 1.2 13.3 6.8 10 7 9 165 9.4 0 9.6 9 09/17/2006 11:10:00 10.6 1.3 14.9 7.6 8.2 1.5 14.5 4.9 10.5 1.3 14.1 7.6 10 6 26 165 9.4 0 9.8 9 09/17/2006 11:20:00 9.6 1.5 14.1 6.1 7.8 1.8 13.3 3.8 9.8 1.6 14.5 6.8 9 8 12 165 9.3 0 9.6 9 09/17/2006 11:30:00 9.4 1.3 13.3 5.3 7.5 1.5 11.1 4.6 9.4 1.2 13.3 6.1 10 8 14 165 9.2 0 9.6 9 09/17/2006 11:40:00 9.2 1.5 13.3 6.1 6.9 1.7 11.5 4.2 9.2 1.6 14.1 6.1 6 7 2 165 9.2 0 9.6 8.8 09/17/2006 11:50:00 10.6 1.5 14.1 6.8 7.9 1.5 12.2 4.2 10.7 1.6 14.5 7.2 8 7 358 165 9.2 0 9.3 8.8 09/17/2006 12:00:00 11.1 1.3 14.1 8 8.4 1.2 11.5 4.9 11.1 1.5 14.5 7.6 7 8 7 165 9.1 0.1 9.3 8.5 09/17/2006 12:10:00 10.7 1.5 15.3 6.5 8.1 1.5 13.7 4.9 10.7 1.6 14.5 6.8 5 8 7 165 9 0.2 9.3 8.5 09/17/2006 12:20:00 10.9 1.5 15.3 7.6 8.4 1.4 11.5 5.3 11.1 1.6 15.6 8 9 7 360 165 8.9 0.2 9.3 8.5 09/17/2006 12:30:00 10.2 1.3 13.7 6.8 7.9 1.4 11.5 4.2 10.1 1.4 14.1 6.5 8 7 3 165 8.9 0.2 9 8.5 09/17/2006 12:40:00 10.5 1.2 13.7 8 7.8 1.3 11.1 4.9 10.6 1.3 14.1 7.6 8 6 6 165 8.9 0.1 9 8.5 09/17/2006 12:50:00 9.9 1 13 7.6 7.6 1.5 12.6 4.6 10.1 1 12.6 7.2 9 6 10 165 8.9 0.1 9 8.5 09/17/2006 13:00:00 10.6 1.1 13.7 7.6 8.7 1.6 12.2 4.6 10.8 1.2 14.1 7.2 12 6 12 165 8.9 0.1 9 8.3 09/17/2006 13:10:00 11 1.3 14.9 8.8 9.1 1.9 14.1 4.9 11.2 1.4 15.3 8 12 7 15 165 8.9 0.2 9.3 8.3 09/17/2006 13:20:00 11.1 1.1 13.7 7.6 9.2 1.7 13 5.3 11.2 1.3 14.5 7.6 12 6 13 165 9 0.2 9.3 8.5 09/17/2006 13:30:00 10.5 1.1 14.1 6.8 8.5 1.5 13 4.9 10.6 1.2 13.7 7.6 12 6 12 165 9 0.1 9.3 8.8 09/17/2006 13:40:00 10.1 0.9 12.2 7.2 8.3 1.5 11.5 4.9 10.2 1 12.6 7.2 12 6 17 165 9.1 0 9.3 8.8 09/17/2006 13:50:00 9.9 0.9 11.8 7.6 7.6 1.3 10.7 4.6 10 1 12.6 7.6 10 6 15 165 9.1 0 9.3 8.8 09/17/2006 14:00:00 10 1.2 13.3 7.2 8 1.7 12.2 4.6 10 1.2 13.3 6.8 11 6 10 165 9.2 0 9.3 8.8 09/17/2006 14:10:00 9.6 1 12.2 6.8 7.4 1.5 11.1 4.6 9.8 1.2 12.6 6.5 10 6 5 165 9.3 0 9.6 9 09/17/2006 14:20:00 8.9 1.1 11.5 6.5 6.5 1.5 10.7 3 9 1.2 12.6 5.7 8 7 10 165 9.4 0 9.6 8.8 09/17/2006 14:30:00 8.4 1 10.7 5.7 6.6 1.5 10.7 3.4 8.5 1 11.1 5.3 11 6 21 165 9.4 0 9.6 9 09/17/2006 14:40:00 8 0.9 9.9 4.9 6 1.4 9.5 3 8 1 10.3 5.7 9 7 5 165 9.4 0 9.6 9 09/17/2006 14:50:00 8.4 0.9 11.5 6.1 6.9 1.7 11.5 3.4 8.5 1 11.1 6.1 14 8 12 165 9.6 0 9.6 9.3 09/17/2006 15:00:00 7.1 0.9 9.1 4.6 5.7 1.2 9.1 3.4 7.3 0.8 9.5 5.3 12 8 21 165 9.6 0 9.6 9.3 09/17/2006 15:10:00 7.4 0.9 9.5 4.9 6.2 1.3 9.1 3.4 7.6 1 9.9 5.3 14 8 11 165 9.6 0 9.8 9.3 09/17/2006 15:20:00 7.8 0.7 9.9 6.1 7.1 1 9.9 3.8 7.9 0.8 9.9 5.7 18 5 16 165 9.6 0 9.6 9.3 09/17/2006 15:30:00 8.1 1 10.3 5.3 7.2 1.2 9.9 3.8 8 1 10.3 5.3 17 7 16 165 9.6 0 9.6 9.3 09/17/2006 15:40:00 7.3 1 9.5 4.6 5.5 1.3 8.8 2.6 7.5 1 10.3 4.6 10 7 7 165 9.5 0 9.6 9.3 09/17/2006 15:50:00 7.3 0.9 9.5 4.9 5.7 1.5 9.1 3 7.4 0.9 9.5 4.6 10 8 355 165 9.5 0 9.6 9 09/17/2006 16:00:00 6.5 1 8.8 4.2 4.5 1 7.6 1.9 6.7 1 9.1 4.9 5 6 4 165 9.4 0 9.8 9 09/17/2006 16:10:00 5.4 0.8 8 3.8 4.5 1.2 8 1.9 5.6 0.9 8.4 4.2 13 8 22 165 9.5 0 9.6 9 09/17/2006 16:20:00 6.1 1 8.8 3.8 5 1.3 8 2.6 6.3 0.9 8.8 4.2 13 10 15 165 9.5 0 9.6 9.3 09/17/2006 16:30:00 6.7 0.8 8.4 4.6 5.8 1 8 3 6.7 0.8 8.8 4.9 16 6 14 165 9.5 0 9.8 9.3 09/17/2006 16:40:00 6.8 1 9.9 4.2 5.5 1.3 9.1 3 7 1 9.9 4.9 12 7 18 165 9.6 0 9.8 9.3 09/17/2006 16:50:00 6.2 0.9 9.1 3.8 4.5 1.2 8.4 1.9 6.4 0.9 9.5 4.2 8 8 13 165 9.5 0 9.8 9 09/17/2006 17:00:00 5.7 0.6 7.6 4.2 4.2 0.9 6.8 2.3 5.8 0.6 7.6 3.4 9 8 7 165 9.5 0 9.6 9.3 09/17/2006 17:10:00 6.6 0.9 8.4 3.8 4.7 1.1 8 2.3 6.7 0.9 8.4 3.8 2 9 7 165 9.5 0 9.6 9.3 09/17/2006 17:20:00 6 0.9 8.4 4.2 4.6 1.4 8.4 1.9 6.2 0.9 8.8 4.6 1 11 356 165 9.5 0 9.6 9.3 09/17/2006 17:30:00 6.3 1.2 8.8 3.8 4.5 1 8.4 2.3 6.6 1.1 9.1 4.6 2 8 5 165 9.5 0 9.6 9.3 09/17/2006 17:40:00 5.2 0.7 6.8 3.4 4.5 1.2 6.8 1.9 5.2 0.7 6.8 3.4 352 9 360 165 9.5 0 10.1 9.3 09/17/2006 17:50:00 4.9 1 7.6 2.3 4.7 1 7.2 1.9 5 0.8 8 3.4 343 10 15 165 9.5 0 9.6 9.3 09/17/2006 18:00:00 5.2 0.6 6.8 3.4 4.4 0.9 6.8 2.3 5.3 0.6 7.2 3.8 349 8 357 165 9.4 0 9.6 9 09/17/2006 18:10:00 5.6 0.7 7.6 4.2 5.2 1 7.6 2.3 5.5 0.7 8 3.8 348 7 352 165 9.4 0 9.6 9 09/17/2006 18:20:00 5.9 0.8 9.1 4.2 4.9 1.1 8.4 2.6 5.8 0.8 7.6 4.2 352 8 350 165 9.4 0 9.6 9 09/17/2006 18:30:00 5.4 0.8 7.6 3.4 4.9 1.2 7.6 2.3 5.4 0.7 7.6 3.8 347 7 338 165 9.4 0 9.8 9 09/17/2006 18:40:00 5.4 0.7 7.2 3.4 4.5 1.1 7.2 2.3 5.4 0.7 7.2 3.4 349 8 353 165 9.4 0 9.6 9 09/17/2006 18:50:00 6 0.7 8 4.2 4.1 1 7.2 1.9 6.1 0.8 8 3.8 356 6 357 165 9.4 0 9.6 9 09/17/2006 19:00:00 5.8 0.7 7.6 4.2 3.9 1.1 7.2 1.9 5.9 0.6 7.6 4.2 358 6 355 165 9.3 0 9.6 9 09/17/2006 19:10:00 5 0.5 6.5 3.8 3.4 0.8 5.3 1.9 5.2 0.5 6.1 3.8 2 9 360 165 9.2 0 9.3 9 09/17/2006 19:20:00 6 0.7 8.4 4.6 4.6 1.2 7.6 1.9 6.2 0.6 7.6 4.2 354 8 339 165 9.1 0 9.3 8.8 09/17/2006 19:30:00 6.4 0.8 8 4.6 4 0.9 6.5 2.3 6.6 0.9 8.8 4.6 2 6 5 165 9 0 9.3 8.8 09/17/2006 19:40:00 5.9 0.6 8 4.2 4 1.2 7.2 1.9 6 0.6 7.6 4.6 357 7 7 165 9 0 9.3 8.8 09/17/2006 19:50:00 6.5 0.9 9.1 4.6 4.2 1 7.6 2.3 6.7 0.8 9.5 5.3 1 7 12 165 9 0 9 8.5 09/17/2006 20:00:00 7.2 0.6 8.4 5.3 4.3 1 7.6 2.6 7.3 0.7 8.8 5.3 4 6 14 165 9 0 9.3 8.8 09/17/2006 20:10:00 6.8 0.8 8.4 4.6 4 0.8 6.8 2.3 7.1 0.8 9.1 4.9 3 5 5 165 9 0 9.3 8.8 09/17/2006 20:20:00 6.6 0.8 8.4 4.2 4.4 0.9 7.2 2.6 6.7 0.9 8.8 4.6 1 7 3 165 9 0 9.3 8.5 09/17/2006 20:30:00 7.2 0.5 8.8 5.7 4.7 1 7.6 3 7.6 0.5 9.1 6.1 7 5 13 165 9.1 0 9.3 8.8 09/17/2006 20:40:00 6.7 0.7 8.4 4.2 4.7 1.2 8 2.3 6.9 0.7 8.8 4.9 7 8 9 165 9.1 0 9.3 8.8 09/17/2006 20:50:00 6.3 0.7 8.4 4.9 4.4 1.1 8.4 2.3 6.6 0.6 8.4 5.3 6 8 21 165 9 0 9.3 8.8 09/17/2006 21:00:00 6 0.7 8 4.6 3.9 0.9 6.5 1.9 6.5 0.6 8 4.6 1 6 3 165 9 0 9.6 8.8 09/17/2006 21:10:00 5.3 0.5 6.8 4.2 3.1 0.7 5.3 1.9 5.7 0.4 6.8 4.6 2 5 6 165 9 0 9.3 8.8 09/17/2006 21:20:00 5.6 0.6 7.2 4.2 3.7 0.9 6.8 1.9 5.8 0.6 8 4.2 3 7 360 165 9 0 9.3 8.8 09/17/2006 21:30:00 5.8 0.7 7.6 4.2 4 1.2 7.6 1.9 6.1 0.7 8 4.2 8 7 18 165 9.1 0 9.6 8.8 09/17/2006 21:40:00 5.7 0.7 7.2 3.8 3.8 1 6.5 1.9 6.1 0.8 8 4.2 7 5 7 165 9.2 0 9.6 9 09/17/2006 21:50:00 4.9 0.5 6.5 3.8 2.7 0.6 6.1 1.5 5.3 0.4 6.5 3.8 2 5 10 165 9.2 0 9.6 9 09/17/2006 22:00:00 5.1 0.5 6.5 3.8 3 0.6 4.9 1.5 5.6 0.5 6.5 3.8 3 5 2 165 9.2 0 9.3 9 09/17/2006 22:10:00 5.3 0.5 6.8 3.8 3 0.7 5.3 1.5 5.6 0.5 6.8 4.2 3 5 11 165 9.1 0 9.3 8.8 09/17/2006 22:20:00 5.6 0.6 8 4.2 3.9 1 7.2 1.9 6 0.6 8 4.6 9 6 12 165 9.2 0 9.3 8.8 09/17/2006 22:30:00 5.3 0.5 6.5 4.2 3.4 0.8 5.7 1.5 5.6 0.4 6.5 4.2 7 5 3 165 9.2 0 9.6 9 09/17/2006 22:40:00 5 0.5 6.5 4.2 3.3 1 6.5 1.5 5.4 0.5 6.8 4.6 1 8 12 165 9.2 0 9.3 8.8 09/17/2006 22:50:00 4.9 0.4 6.1 3.8 2.8 0.6 5.3 1.9 5.2 0.4 6.1 4.2 5 4 6 165 9.2 0 9.3 9 09/17/2006 23:00:00 5 0.4 6.5 3.8 3 0.9 5.7 1.5 5.4 0.4 6.5 4.6 4 6 11 165 9.1 0 9.6 8.8 09/17/2006 23:10:00 4.8 0.4 5.7 3.8 2.7 0.5 4.9 1.5 5.2 0.4 6.1 4.2 2 5 348 165 9 0 9.3 8.8 09/17/2006 23:20:00 5.2 0.5 6.5 4.2 3.5 0.9 6.1 1.9 5.4 0.6 7.2 4.2 7 7 5 165 9 0 9 8.5 09/17/2006 23:30:00 5.6 0.4 6.5 4.6 5.1 0.7 6.5 3 5.9 0.5 7.2 4.6 17 4 15 165 9 0 9.3 8.8 09/17/2006 23:40:00 5.2 0.3 5.7 4.2 4.1 0.6 6.1 2.6 5.6 0.4 6.5 4.6 13 3 8 165 9 0 9 8.5 09/17/2006 23:50:00 4.6 0.4 5.7 3.8 2.7 0.7 4.9 1.5 4.9 0.3 5.7 4.2 7 4 14 165 8.9 0 9 8.5 09/18/2006 00:00:00 4.8 0.3 5.3 4.2 3.3 0.6 4.6 1.5 5.1 0.3 6.1 4.2 11 3 2 165 8.9 0 9 8.5 09/18/2006 00:10:00 4.8 0.3 5.3 3.8 4.2 0.5 4.9 2.6 5 0.3 5.7 4.2 16 3 15 165 9 0 9 8.5 09/18/2006 00:20:00 4.9 0.4 5.7 4.2 4.6 0.6 5.7 3 5.2 0.4 6.1 4.6 18 3 19 165 9 0 9 8.8 09/18/2006 00:30:00 4.8 0.3 5.7 3.8 4.8 0.4 5.7 3.4 5.2 0.4 6.5 4.2 20 3 20 165 9 0 9 8.5 09/18/2006 00:40:00 4.6 0.3 5.3 3.4 4.2 0.6 5.3 2.3 4.8 0.3 5.3 4.2 18 3 16 165 9 0 9 8.5 09/18/2006 00:50:00 3.3 0.5 4.6 2.3 2.8 0.7 4.2 0.7 3.8 0.4 4.9 2.6 15 4 18 165 9 0 9 8.5 09/18/2006 01:00:00 2.7 0.3 3.8 1.9 2.6 0.4 3.8 1.1 3.2 0.3 4.2 2.3 23 4 29 165 8.9 0.1 9.3 8.5 09/18/2006 01:10:00 2.9 0.4 3.8 1.9 2.7 0.4 3.8 1.9 3.3 0.4 4.6 2.3 22 5 16 165 8.9 0.1 9 8.5 09/18/2006 01:20:00 2 0.3 2.6 1.1 1.8 0.4 3 0.7 2.6 0.3 3.4 1.9 24 10 34 165 8.9 0.1 9 8.5 09/18/2006 01:30:00 2.2 0.4 3 1.5 2.2 0.4 3.4 1.5 2.8 0.3 3.4 2.3 36 5 41 165 8.8 0 9 8.5 09/18/2006 01:40:00 1.9 0.3 2.6 1.5 1.9 0.3 2.6 1.1 2.4 0.3 3 1.5 32 6 26 165 8.6 0.1 8.8 8.3 09/18/2006 01:50:00 1.7 0.2 2.3 1.1 1.6 0.3 2.3 1.1 2.2 0.3 3 1.5 33 5 39 165 8.5 0.1 8.8 8.3 09/18/2006 02:00:00 2.3 0.4 3 1.5 2.1 0.5 3 0.7 2.9 0.3 3.8 2.3 21 7 26 165 8.5 0.1 8.8 8.3 09/18/2006 02:10:00 2.7 0.3 3.4 2.3 2.5 0.4 3.4 1.5 3.2 0.3 3.8 2.3 21 3 21 165 8.5 0.1 8.8 8.3 09/18/2006 02:20:00 2.8 0.4 3.8 1.9 2.7 0.4 3.8 1.9 3.3 0.3 3.8 2.3 28 4 29 165 8.5 0.1 8.8 8 09/18/2006 02:30:00 2 0.8 3.8 0.7 2 0.8 3.4 0.4 2.4 0.8 3.8 0.7 46 12 50 165 8.5 0.1 8.8 8.3 09/18/2006 02:40:00 2.2 0.5 3 0.7 2.2 0.5 3 0.7 2.5 0.5 3.4 1.1 38 10 30 165 8.6 0.1 8.8 8.3 09/18/2006 02:50:00 2.2 0.3 2.6 1.5 2.2 0.3 2.6 1.5 2.6 0.3 3 1.9 34 6 29 165 8.6 0 8.8 8.3 09/18/2006 03:00:00 2.4 0.4 3.8 1.5 2.5 0.4 3.8 1.5 2.7 0.3 3.4 1.9 37 7 46 165 8.7 0 9 8.3 09/18/2006 03:10:00 2.5 0.5 3.8 1.5 2.5 0.5 3.8 1.5 2.7 0.4 3.8 1.5 52 8 68 165 8.8 0.1 9 8.5 09/18/2006 03:20:00 2 0.3 3 1.1 2 0.4 3 1.5 2.5 0.4 3.4 1.5 45 8 60 165 8.9 0 9 8.5 09/18/2006 03:30:00 2.5 0.3 3.4 1.5 2.5 0.3 3.4 1.5 3 0.4 3.8 1.5 43 8 51 165 8.9 0 9 8.5 09/18/2006 03:40:00 2.3 0.4 3.8 1.5 2.4 0.4 3.8 1.1 2.6 0.4 3.8 1.9 54 10 75 165 8.9 0 9 8.5 09/18/2006 03:50:00 2.3 0.6 3.8 0.4 2.4 0.6 3.8 0.4 2.2 0.5 3.4 0.7 78 13 62 165 9 0 9 8.5 09/18/2006 04:00:00 3.3 0.6 4.6 1.5 3.4 0.6 4.9 1.5 3.2 0.6 4.9 1.5 91 8 94 165 9.6 0.2 10.1 8.8 09/18/2006 04:10:00 3.3 0.5 4.6 1.5 3.4 0.5 4.6 1.5 3.3 0.6 4.6 1.9 94 9 94 165 10 0 10.3 9.6 09/18/2006 04:20:00 3.1 0.5 4.2 1.5 3.3 0.5 4.2 1.5 3.1 0.5 4.2 1.1 101 7 98 165 10.1 0 10.3 9.8 09/18/2006 04:30:00 3.5 0.4 4.6 2.6 3.7 0.4 4.6 2.6 3.5 0.4 4.6 2.3 109 10 116 165 10 0 10.3 9.6 09/18/2006 04:40:00 3.5 0.4 4.6 2.6 3.6 0.4 4.9 2.6 3.6 0.4 4.9 2.3 118 7 121 165 10.1 0 10.3 9.6 09/18/2006 04:50:00 3.4 0.4 4.2 1.9 3.4 0.4 4.6 2.3 3.3 0.5 4.6 2.3 118 6 119 165 9.9 0.2 10.6 9.6 09/18/2006 05:00:00 3.8 0.4 4.9 2.6 3.9 0.5 4.9 2.6 3.7 0.5 4.9 2.6 118 8 114 165 9.8 0 10.1 9.3 09/18/2006 05:10:00 4.3 0.7 6.1 2.6 4.3 0.6 6.1 3 4.2 0.6 5.7 3 127 10 136 165 10 0 10.3 9.3 09/18/2006 05:20:00 4.7 0.6 6.1 3 4.7 0.6 6.5 3 4.5 0.6 6.1 2.3 129 9 123 165 9.7 0 9.8 9.6 09/18/2006 05:30:00 4.9 0.7 6.8 3.4 4.9 0.7 6.8 3 4.7 0.6 6.5 3 138 9 145 165 9.7 0.1 9.8 9.3 09/18/2006 05:40:00 5 0.7 6.8 3.4 5 0.7 6.8 3.4 5 0.7 6.8 3 139 9 147 165 9.8 0 9.8 9.6 09/18/2006 05:50:00 5 0.5 6.8 3.8 4.9 0.5 7.2 3.8 5 0.5 6.5 3.8 137 7 137 165 9.6 0.1 9.8 9.3 09/18/2006 06:00:00 4.6 0.4 5.7 3.4 4.6 0.4 5.3 3.4 4.6 0.4 6.1 3.4 135 6 127 165 9.6 0.1 10.1 9.6 09/18/2006 06:10:00 4.9 0.5 6.5 3 4.9 0.5 6.5 3 4.7 0.4 6.1 3.8 139 5 139 165 9.7 0 9.8 9.3 09/18/2006 06:20:00 5.7 0.8 8 3.8 5.6 0.8 8.4 3.8 5.5 0.8 8 3.8 138 7 145 165 9.8 0 9.8 9.6 09/18/2006 06:30:00 7 0.9 8.8 3.8 7 1 8.4 3.4 6.8 0.9 8.4 4.2 140 6 141 165 10 0.1 10.3 9.6 09/18/2006 06:40:00 6.2 0.8 8.4 4.6 6.2 0.8 8.4 4.2 6.1 0.8 8 4.2 143 11 121 165 10 0 10.6 9.6 09/18/2006 06:50:00 6.4 0.8 8 3.8 6.2 0.8 8 3.8 6.3 0.8 7.6 3.8 145 10 153 165 10 0.2 10.6 9.6 09/18/2006 07:00:00 6.8 0.9 8.8 4.9 6.8 0.8 9.1 4.9 6.8 0.8 8.4 4.6 143 6 147 165 10 0.2 10.3 9.6 09/18/2006 07:10:00 6.8 0.8 9.1 4.9 6.8 0.8 8.8 4.9 6.7 0.7 8.8 4.9 145 7 154 165 10 0.2 10.3 9.6 09/18/2006 07:20:00 7.6 0.8 9.5 4.9 7.5 0.8 9.1 4.9 7.5 0.8 9.5 5.3 143 6 139 165 10.1 0.1 10.3 9.6 09/18/2006 07:30:00 7.9 0.8 9.5 6.1 7.8 0.8 9.5 5.7 7.8 0.8 9.5 6.1 141 8 146 165 10 0.2 10.3 9.6 09/18/2006 07:40:00 8.3 1 10.3 5.3 8.2 1 10.3 4.6 8 1.1 9.9 4.9 139 8 142 165 10.1 0.2 10.3 9.6 09/18/2006 07:50:00 8.5 0.7 10.3 6.5 8.5 0.7 10.7 6.1 8.3 0.7 9.9 6.1 141 6 132 165 10 0.2 10.9 9.6 09/18/2006 08:00:00 8.9 0.9 11.5 6.1 8.9 0.9 11.1 6.5 8.7 0.8 10.7 6.1 141 7 145 165 10 0.2 10.3 9.6 09/18/2006 08:10:00 9.2 0.8 11.1 7.2 9.1 0.8 11.1 6.8 9 0.7 10.7 7.2 145 6 148 165 10.1 0.2 10.6 9.6 09/18/2006 08:20:00 9.8 1 12.2 7.6 9.8 1 12.2 7.6 9.6 1 11.8 6.8 145 6 147 165 10.2 0.2 10.6 9.8 09/18/2006 08:30:00 10.6 0.7 12.2 8.4 10.6 0.7 12.6 8.4 10.4 0.7 12.2 8.8 144 4 147 165 10.3 0.2 10.9 9.8 09/18/2006 08:40:00 10.4 0.7 12.2 8.4 10.4 0.7 12.2 8 10.1 0.8 12.2 7.2 144 5 135 165 10.3 0.2 10.9 9.8 09/18/2006 08:50:00 10 0.9 12.2 7.2 10 0.9 12.6 7.2 9.8 0.9 12.6 7.2 144 6 147 165 10.3 0.2 10.6 9.8 09/18/2006 09:00:00 10.6 0.7 12.6 9.1 10.7 0.7 12.6 8.8 10.5 0.8 12.6 8.4 144 6 145 165 10.2 0.2 10.6 9.8 09/18/2006 09:10:00 10.4 0.8 12.2 8.4 10.4 0.8 12.2 8.4 10.2 0.9 12.2 8 146 5 142 165 10.3 0.1 10.9 9.8 09/18/2006 09:20:00 10.7 0.8 13 8.4 10.8 0.8 13 8.4 10.6 0.9 13 8.4 145 5 147 165 10.3 0.1 10.6 9.8 09/18/2006 09:30:00 10.4 0.8 12.6 8 10.4 0.8 12.6 8 10.3 0.9 12.6 7.2 144 6 146 165 10.3 0.2 10.9 9.8 09/18/2006 09:40:00 10.9 0.9 13.7 8.4 11 0.9 13.3 8.8 10.7 1 13 8 146 6 145 165 10.3 0.1 10.9 9.8 09/18/2006 09:50:00 11.9 0.8 13.3 9.5 11.8 0.8 13.3 9.1 11.7 0.8 13.3 9.5 147 4 151 165 10.3 0.1 10.9 9.8 09/18/2006 10:00:00 10.8 0.9 13.3 8 10.8 0.8 13 8 10.8 0.9 13 7.2 146 6 152 165 10.3 0.1 10.9 9.8 09/18/2006 10:10:00 10.7 1.1 13.3 8.4 10.7 1.1 13.3 8.4 10.5 1.1 13.7 7.6 146 8 148 165 10.3 0 10.6 9.8 09/18/2006 10:20:00 11.2 0.9 13.3 9.5 11.2 0.9 13.3 9.5 11 1 13.7 8.4 145 5 152 165 10.3 0 10.6 9.8 09/18/2006 10:30:00 10.6 0.8 12.6 8 10.6 0.8 12.6 8 10.5 0.9 13.3 7.6 143 6 139 165 10.3 0.1 10.6 9.8 09/18/2006 10:40:00 10.4 1 13.7 8 10.5 1 13.7 7.6 10.2 1 12.6 7.6 141 6 135 165 10.3 0.1 10.6 9.8 09/18/2006 10:50:00 10 1.1 13 6.5 10 1.1 13 6.5 9.7 1.1 12.6 6.5 141 8 144 165 10.3 0.1 10.6 9.8 09/18/2006 11:00:00 11.2 1.1 14.1 8.4 11.2 1.1 14.1 7.6 11 1.2 14.5 8 141 7 143 165 10.3 0 10.6 9.8 09/18/2006 11:10:00 12.4 1.2 15.6 8 12.4 1.2 15.3 8 12 1.3 15.3 7.6 141 7 150 165 10.3 0.1 10.9 9.8 09/18/2006 11:20:00 12.2 1 15.3 8.8 12.3 1 14.9 9.1 11.7 1.1 14.1 8.4 139 6 140 165 10.3 0.1 10.6 9.8 09/18/2006 11:30:00 12.5 1 15.6 9.1 12.6 1.1 14.9 9.1 12.2 1.2 15.3 9.1 139 6 136 165 10.2 0.1 10.6 9.8 09/18/2006 11:40:00 13.2 1 16.1 10.7 13.2 1 16.4 10.7 13 1.1 16.1 9.9 140 6 141 165 10.1 0.1 10.6 9.8 09/18/2006 11:50:00 13.5 1.2 16.8 10.7 13.7 1.2 16.4 10.7 13.3 1.3 16.4 9.9 140 6 143 165 10.1 0.2 10.6 9.8 09/18/2006 12:00:00 13.7 1.3 16.4 9.1 13.7 1.3 17.2 9.1 13.3 1.3 16.4 9.5 139 6 134 165 10.1 0.2 10.6 9.8 09/18/2006 12:10:00 14.2 1.5 18.3 10.7 14.3 1.5 18.3 9.9 14 1.5 17.9 9.5 140 6 147 165 10.1 0.1 10.9 9.8 09/18/2006 12:20:00 15.4 1.3 18.3 9.9 15.5 1.3 18.7 9.9 14.9 1.6 18.3 10.3 140 7 144 165 10.1 0.1 10.6 9.8 09/18/2006 12:30:00 15.9 1.5 19.5 12.6 15.9 1.5 19.9 12.2 15.6 1.6 19.9 11.1 142 6 141 165 10.2 0.1 10.6 9.8 09/18/2006 12:40:00 15.4 1.1 17.9 11.8 15.5 1.1 18.3 12.2 15.2 1.3 18.7 10.7 142 7 139 165 10.2 0.1 10.6 9.8 09/18/2006 12:50:00 13.8 0.9 16.1 10.3 13.8 0.9 16.1 10.7 13.5 1 15.6 10.7 146 5 137 165 10.2 0.1 10.6 9.8 09/18/2006 13:00:00 12.2 0.6 13.7 10.7 12.3 0.6 13.7 10.7 12.1 0.8 13.7 9.5 147 3 148 165 10.1 0.1 10.6 9.8 09/18/2006 13:10:00 11.8 0.6 13 9.5 11.8 0.6 13.3 9.5 11.7 0.7 13 9.1 146 3 143 165 10 0.2 10.3 9.6 09/18/2006 13:20:00 11.2 0.5 12.6 9.5 11.3 0.5 12.6 9.9 11.1 0.6 12.6 9.1 148 3 148 165 10 0.2 10.3 9.6 09/18/2006 13:30:00 10.7 0.4 11.8 9.5 10.8 0.4 11.8 9.9 10.6 0.6 12.2 8.4 146 3 145 165 9.9 0.1 10.3 9.6 09/18/2006 13:40:00 11.1 0.6 12.6 9.5 11.2 0.6 12.6 9.9 11.2 0.7 13 9.5 144 3 144 165 9.8 0.1 10.1 9.6 09/18/2006 13:50:00 11.4 0.5 13 9.9 11.5 0.5 13 9.5 11.3 0.6 13.3 9.5 145 3 143 165 9.9 0.1 10.6 9.6 09/18/2006 14:00:00 11.1 0.7 12.6 8.8 11.2 0.7 12.6 9.1 11.1 0.8 12.6 8.4 147 4 153 165 10 0.2 10.3 9.6 09/18/2006 14:10:00 11.1 0.6 12.6 8.8 11.2 0.6 12.6 9.1 11 0.7 12.6 9.1 146 3 144 165 10 0.2 10.3 9.6 09/18/2006 14:20:00 11.1 0.6 12.6 9.1 11.1 0.6 12.6 9.1 11.1 0.7 12.6 8.8 146 3 143 165 9.9 0.2 10.3 9.6 09/18/2006 14:30:00 12 1.1 14.5 9.5 12.1 1.1 14.9 9.9 11.8 1.2 14.1 8.8 144 4 139 165 10 0.2 10.3 9.6 09/18/2006 14:40:00 12.9 1.1 16.4 9.9 13 1.1 16.8 9.9 12.8 1.1 16.4 9.1 145 5 142 165 10 0.2 10.3 9.6 09/18/2006 14:50:00 14.1 0.9 16.4 11.5 14.2 0.9 16.4 11.8 14 1 16.4 11.1 144 5 145 165 10 0.2 10.6 9.6 09/18/2006 15:00:00 13 0.9 15.3 10.3 13.1 0.9 16.1 10.7 12.7 1 15.3 9.9 143 6 145 165 10 0.1 10.3 9.6 09/18/2006 15:10:00 13.7 1 16.8 10.7 13.7 1.1 17.2 10.7 13.5 1.2 16.1 10.7 145 6 142 165 10 0.2 10.3 9.6 09/18/2006 15:20:00 12.9 1.1 16.8 9.9 13 1.1 16.8 9.9 12.7 1.2 15.3 9.1 145 6 148 165 10 0.2 10.6 9.6 09/18/2006 15:30:00 13.5 1 15.6 10.3 13.6 1 16.1 9.9 13.2 1.2 16.1 8.8 145 4 146 165 10.1 0.2 10.3 9.6 09/18/2006 15:40:00 12.8 0.8 14.5 10.7 12.8 0.8 14.5 10.3 12.6 1 14.5 9.9 149 3 143 165 10 0.2 10.3 9.6 09/18/2006 15:50:00 12.4 0.7 14.1 10.7 12.4 0.7 14.1 10.7 12.3 0.7 14.5 9.9 150 3 154 165 10 0.2 10.6 9.6 09/18/2006 16:00:00 12.5 0.7 14.1 10.3 12.5 0.7 14.5 10.3 12.3 0.9 14.1 9.5 149 3 147 165 9.9 0.1 10.3 9.6 09/18/2006 16:10:00 13.2 0.7 14.9 11.1 13.2 0.7 14.9 11.1 13 0.9 15.6 10.3 148 3 146 165 9.8 0.1 10.3 9.3 09/18/2006 16:20:00 12.7 0.9 14.5 10.3 12.8 0.9 14.5 10.3 12.5 1.1 14.9 9.5 146 4 147 165 9.8 0.1 10.1 9.3 09/18/2006 16:30:00 12.4 0.6 14.1 10.7 12.5 0.6 14.5 11.1 12.4 0.7 14.1 9.5 146 5 156 165 9.7 0.2 10.3 9 09/18/2006 16:40:00 13.1 0.8 15.3 11.1 13.1 0.8 15.6 11.5 13 0.9 14.9 10.3 147 4 145 165 9.6 0.3 9.8 9 09/18/2006 16:50:00 12.9 0.7 14.9 11.1 12.9 0.7 14.9 10.7 13 0.8 14.9 10.7 147 4 148 165 9.6 0.2 9.8 9 09/18/2006 17:00:00 12.9 0.9 15.3 10.7 13 0.8 15.3 10.7 13 1 15.3 9.5 145 6 143 165 9.6 0.2 10.3 9 09/18/2006 17:10:00 13.7 1.1 16.4 11.1 13.8 1.1 16.1 11.1 13.7 1.1 16.1 10.7 146 5 147 165 9.7 0.1 9.8 9 09/18/2006 17:20:00 15.4 1.2 17.9 12.6 15.4 1.2 17.9 12.6 15.3 1.5 18.3 10.3 150 4 153 165 9.3 0.3 9.8 8.8 09/18/2006 17:30:00 14.3 0.9 16.4 11.5 14.3 0.8 16.4 11.1 14 1 16.1 11.1 150 3 148 165 8.9 0 9 8.5 09/18/2006 17:40:00 12.6 0.8 15.3 10.7 12.7 0.7 15.3 11.1 12.5 0.8 14.9 9.9 152 3 157 165 8.8 0 9 8.5 09/18/2006 17:50:00 12.2 1 14.5 9.9 12.2 1 14.1 9.9 12.3 1.1 14.5 9.5 151 4 158 165 8.8 0 9 8.5 09/18/2006 18:00:00 12.4 0.8 15.3 10.3 12.4 0.8 15.3 10.7 12.4 1 14.9 9.5 147 3 145 165 9 0 9.3 8.8 09/18/2006 18:10:00 13 0.8 14.9 10.7 13.1 0.8 14.9 10.7 13 0.8 15.3 9.1 145 5 148 165 9 0 9.3 8.8 09/18/2006 18:20:00 14 1.2 16.4 10.7 14 1.1 16.4 11.1 14 1.2 16.8 10.3 144 6 151 165 9 0 9.3 8.5 09/18/2006 18:30:00 13.5 1 16.8 11.1 13.6 1 17.2 10.7 13.3 1 16.4 11.1 142 5 135 165 9.2 0 9.3 8.8 09/18/2006 18:40:00 13.6 1 16.8 9.9 13.7 1.1 16.8 10.3 13.5 1.2 17.2 9.5 144 6 140 165 9.2 0 9.3 9 09/18/2006 18:50:00 14.4 1.2 17.9 9.9 14.6 1.2 18.3 10.3 14.2 1.3 16.8 9.9 141 6 140 165 9 0 9.3 8.8 09/18/2006 19:00:00 12.7 1 15.6 9.1 12.8 1 15.6 9.1 12.5 1.2 15.6 8.4 142 7 142 165 9 0 9 8.8 09/18/2006 19:10:00 13.1 1.2 16.4 9.1 13.2 1.2 16.4 9.9 12.8 1.2 16.1 9.1 139 7 139 165 8.9 0 9 8.5 09/18/2006 19:20:00 13 1.2 16.4 9.1 13.1 1.2 16.4 9.5 12.7 1.3 16.1 9.1 139 6 142 165 8.9 0 9 8.5 09/18/2006 19:30:00 12.8 1.5 16.4 9.1 12.9 1.5 16.8 8.4 12.5 1.6 16.4 7.6 132 9 128 165 8.9 0 9 8.5 09/18/2006 19:40:00 12.7 1.5 17.2 8.8 12.9 1.5 17.2 8.8 12.4 1.5 16.4 8 128 8 121 165 8.9 0 9 8.5 09/18/2006 19:50:00 12.2 1.7 16.8 8 12.4 1.7 17.2 7.6 11.9 1.7 16.4 7.6 125 8 118 165 8.9 0.1 9 8.5 09/18/2006 20:00:00 12.6 1.6 16.4 8.8 12.8 1.6 16.4 8.8 12.2 1.7 17.2 7.6 118 8 114 165 9 0.1 9 8.5 09/18/2006 20:10:00 11.6 1.6 15.6 7.2 11.8 1.6 16.1 7.2 11.1 1.7 15.3 6.5 119 9 122 165 8.9 0.1 9 8.5 09/18/2006 20:20:00 11 1.3 14.9 7.2 11.2 1.3 14.5 7.2 10.6 1.5 14.1 6.1 119 8 119 165 9 0.1 9 8.5 09/18/2006 20:30:00 11.7 1.5 16.1 8 11.8 1.5 16.8 8 11.2 1.5 15.6 7.2 123 8 119 165 9 0 9.3 8.8 09/18/2006 20:40:00 12.2 1.3 16.1 9.1 12.4 1.3 16.4 9.1 11.9 1.6 16.1 7.6 124 8 126 165 9 0 9.3 8.5 09/18/2006 20:50:00 12.9 1.4 16.1 8.4 13.1 1.4 16.8 8.4 12.6 1.5 16.4 9.1 126 8 119 165 9.1 0 9.3 8.8 09/18/2006 21:00:00 12.8 1.5 16.1 8 13.1 1.5 16.4 9.1 12.5 1.5 16.1 8.4 126 7 137 165 9.1 0 9.3 8.8 09/18/2006 21:10:00 11.5 1.3 15.3 8.4 11.8 1.3 15.6 8 11.4 1.2 14.1 7.2 125 8 126 165 9.1 0 9.3 8.8 09/18/2006 21:20:00 12.3 1.7 16.8 8.4 12.6 1.8 17.2 8.4 12 1.8 16.8 7.6 124 7 118 165 9.2 0 9.6 9 09/18/2006 21:30:00 14.1 1.6 19.1 9.5 14.3 1.6 19.5 9.5 13.7 1.7 19.5 9.1 125 8 119 165 9.4 0 9.6 9 09/18/2006 21:40:00 14.1 1.5 17.6 10.3 14.3 1.5 18.3 9.5 13.5 1.7 17.9 9.1 123 9 130 165 9.4 0 9.6 9 09/18/2006 21:50:00 13.6 1.5 18.7 10.3 13.9 1.6 18.7 9.1 13.4 1.7 17.6 8.8 130 8 125 165 9.5 0 9.6 9 09/18/2006 22:00:00 14.8 1.9 20.2 10.3 15.1 1.9 20.2 10.3 14.6 2.1 20.2 10.3 128 8 134 165 9.5 0 9.8 9.3 09/18/2006 22:10:00 15.4 1.8 20.2 11.1 15.6 1.9 20.6 11.5 15.1 2.1 20.6 10.3 129 7 121 165 9.6 0 9.6 9 09/18/2006 22:20:00 15 1.7 19.5 11.1 15.3 1.8 19.9 10.7 14.5 1.9 19.9 9.9 122 7 119 165 9.6 0 9.8 9.3 09/18/2006 22:30:00 13.7 2.1 19.5 8.4 14 2.2 20.2 8.4 13.3 2.3 18.7 6.8 124 9 121 165 9.6 0 9.8 9.3 09/18/2006 22:40:00 14 2 19.1 7.6 14.2 2 20.2 6.8 13.7 1.9 18.7 8.4 124 8 116 165 9.8 0 9.8 9.6 09/18/2006 22:50:00 14.3 1.7 18.7 9.9 14.5 1.7 19.1 10.3 13.7 1.7 18.3 9.1 122 8 122 165 9.8 0 9.8 9 09/18/2006 23:00:00 14.7 1.7 20.6 9.5 14.9 1.7 19.5 9.9 14.5 1.7 18.7 9.5 125 8 118 165 9.9 0 10.1 9.3 09/18/2006 23:10:00 13.9 1.7 19.5 10.3 14.2 1.7 19.9 10.3 13.6 1.9 19.5 9.5 125 8 126 165 10 0 10.1 9.3 09/18/2006 23:20:00 13.9 1.4 17.9 9.9 14.1 1.4 18.3 9.9 13.2 1.7 17.9 9.1 126 8 139 165 10 0 10.1 9.3 09/18/2006 23:30:00 12.9 1.7 17.6 9.1 13.2 1.7 18.3 9.5 12.5 1.9 17.9 8.8 124 8 129 165 10 0 10.6 9.6 09/18/2006 23:40:00 12.9 1.5 16.4 8.8 13.2 1.5 16.8 8.8 12.5 1.5 16.4 8 123 6 116 165 10.1 0.2 10.3 9.6 09/18/2006 23:50:00 11.8 1.2 14.9 8.4 11.9 1.3 15.3 8 11.4 1.2 14.9 7.6 128 8 101 165 10.1 0.1 10.6 9.8 09/19/2006 00:00:00 11.9 1.5 16.8 8.8 12 1.5 17.2 8 11.4 1.7 17.9 7.6 133 8 133 165 10.1 0.1 10.6 9.8 09/19/2006 00:10:00 10.8 2.1 17.2 7.2 10.9 2.2 17.6 7.2 10.7 2.1 17.2 7.2 142 7 141 165 10 0.1 10.3 9.6 09/19/2006 00:20:00 7.5 0.9 10.3 6.1 7.4 0.9 9.9 6.1 7.5 0.8 9.9 6.1 152 5 148 165 9.8 0.1 10.3 9 09/19/2006 00:30:00 5.6 0.8 7.2 3.4 5.5 0.7 6.8 3.8 5.7 0.9 7.2 3.8 166 12 156 165 9.3 0.1 9.6 9 09/19/2006 00:40:00 5.2 0.6 6.8 3.8 5 0.6 6.5 3.4 5.1 0.7 6.8 3.4 179 7 181 165 9.4 0.1 9.6 9 09/19/2006 00:50:00 4.2 0.8 6.1 2.6 3.9 0.8 5.7 2.3 4.2 0.8 6.1 3 174 7 178 165 9.4 0 9.6 9 09/19/2006 01:00:00 4.5 0.7 6.1 3.4 4.3 0.7 6.1 3 4.5 0.7 6.1 3 161 7 163 165 9.4 0 9.6 9 09/19/2006 01:10:00 6.9 0.8 8.8 4.6 6.6 0.8 8 4.6 6.9 0.8 8.8 4.6 163 7 165 165 9.1 0.1 9.3 8.8 09/19/2006 01:20:00 8.3 0.6 9.5 6.5 8.1 0.6 9.1 6.1 8.2 0.8 9.5 5.7 165 14 164 165 8.8 0 9 8.5 09/19/2006 01:30:00 7.2 0.9 9.1 4.6 7 0.9 9.1 4.2 7 0.9 9.1 4.6 158 12 164 165 8.7 0 9 8.3 09/19/2006 01:40:00 7.1 0.6 8.8 5.3 6.9 0.6 8.8 4.9 7.2 0.6 8.8 5.3 158 8 158 165 8.8 0 9 8.5 09/19/2006 01:50:00 7 0.4 8.8 6.1 6.8 0.4 8 5.7 7.1 0.4 8.8 6.1 156 4 162 165 8.9 0.1 9 8.5 09/19/2006 02:00:00 6.4 0.4 7.2 5.7 6.2 0.4 7.2 5.3 6.5 0.4 7.6 5.7 154 4 157 165 8.9 0 9 8.5 09/19/2006 02:10:00 6.1 0.4 7.2 5.3 5.9 0.4 6.8 4.9 6.1 0.4 7.2 4.6 153 5 161 165 9 0 9 8.5 09/19/2006 02:20:00 6.3 0.5 7.2 4.9 6.1 0.5 7.2 4.9 6.3 0.4 7.2 4.9 152 4 159 165 9 0.1 9 8.8 09/19/2006 02:30:00 5.5 0.7 7.2 4.2 5.3 0.7 6.8 3.8 5.6 0.7 7.2 3.8 156 5 162 165 9 0.1 9.3 8.8 09/19/2006 02:40:00 5.4 0.5 6.5 4.2 5.2 0.5 6.5 4.2 5.2 0.5 6.5 3.4 143 6 151 165 8.9 0 9 8.5 09/19/2006 02:50:00 6.6 0.8 8 4.6 6.5 0.8 8.4 4.6 6.3 1 8 3.4 141 8 141 165 9 0 9.3 8.5 09/19/2006 03:00:00 7.4 0.7 9.5 5.7 7.3 0.8 9.5 5.3 7.2 0.7 9.5 5.3 147 6 150 165 9.3 0 9.6 9 09/19/2006 03:10:00 7.9 0.6 9.9 5.7 7.9 0.6 9.5 6.1 7.6 0.6 8.8 5.3 142 6 145 165 9.6 0 9.6 9 09/19/2006 03:20:00 8.6 0.5 9.9 6.8 8.5 0.5 9.5 6.8 8.2 0.7 9.9 6.1 145 4 152 165 9.6 0 9.6 9.3 09/19/2006 03:30:00 8.1 0.5 9.1 6.8 8.1 0.5 9.5 6.8 8 0.6 9.1 6.1 146 3 145 165 9.5 0 9.6 9.3 09/19/2006 03:40:00 7.8 0.5 8.8 6.5 7.7 0.5 8.8 6.5 7.7 0.5 9.1 6.5 149 3 152 165 9.5 0 9.6 9 09/19/2006 03:50:00 8.6 0.5 9.9 7.6 8.6 0.4 9.9 7.6 8.5 0.5 9.5 6.8 145 4 140 165 9.4 0 9.6 9 09/19/2006 04:00:00 9.1 0.7 10.7 7.6 9.1 0.8 10.7 7.6 8.8 0.8 10.7 6.5 143 4 145 165 9.5 0 9.8 9.3 09/19/2006 04:10:00 9.9 0.5 11.1 8.4 9.9 0.5 11.1 8.4 9.7 0.6 11.1 8 143 3 143 165 9.6 0 9.6 9.3 09/19/2006 04:20:00 9.5 0.5 11.1 8 9.5 0.6 11.5 8 9.2 0.6 11.1 7.6 145 4 139 165 9.6 0.1 9.6 9.3 09/19/2006 04:30:00 9.2 0.4 10.3 8 9.3 0.5 10.3 8 9 0.6 10.3 7.6 146 3 144 165 9.6 0.1 9.6 9.3 09/19/2006 04:40:00 9.6 0.6 11.1 7.6 9.6 0.6 11.1 7.6 9.5 0.6 10.7 7.2 142 4 139 165 9.5 0 9.6 9.3 09/19/2006 04:50:00 9.4 0.6 11.1 8 9.4 0.6 11.1 8 9.3 0.6 10.7 7.6 147 4 136 165 9.5 0 9.6 9 09/19/2006 05:00:00 8.6 0.6 10.3 6.8 8.6 0.6 10.3 7.2 8.5 0.7 9.9 6.5 146 4 143 165 9.6 0 9.8 9.3 09/19/2006 05:10:00 7.6 0.5 9.1 6.5 7.6 0.5 8.8 6.1 7.6 0.6 9.1 6.1 145 3 147 165 9.6 0.1 9.6 9.3 09/19/2006 05:20:00 8.5 0.6 9.9 6.5 8.5 0.6 9.9 6.5 8.4 0.6 9.5 6.5 143 5 147 165 9.6 0 9.6 9.3 09/19/2006 05:30:00 8.9 0.9 10.7 6.5 8.8 0.9 10.7 6.8 8.6 0.9 10.7 6.1 142 5 142 165 9.5 0 9.6 9.3 09/19/2006 05:40:00 10.2 0.8 12.2 7.6 10.2 0.8 12.6 7.6 10 0.9 12.6 6.8 143 6 139 165 9.6 0 9.6 9.3 09/19/2006 05:50:00 10.6 0.8 13 8.8 10.7 0.8 12.6 8.8 10.6 0.8 12.2 8 145 4 143 165 9.6 0.1 9.8 9.3 09/19/2006 06:00:00 11.1 0.7 13 9.1 11.1 0.7 12.6 9.5 11 0.8 12.6 8.8 143 5 143 165 9.6 0 9.8 9.3 09/19/2006 06:10:00 10.6 0.9 12.6 7.6 10.6 0.8 12.6 7.6 10.3 0.9 12.2 7.2 143 6 147 165 9.6 0 9.8 9.6 09/19/2006 06:20:00 9.3 1 11.8 7.2 9.3 1 11.5 6.8 9.2 1 11.1 6.5 146 6 143 165 9.6 0 9.8 9.6 09/19/2006 06:30:00 11.3 1 13.7 8.8 11.4 1 14.1 8.4 10.9 1.2 13.7 7.6 138 7 131 165 9.7 0 9.8 9.6 09/19/2006 06:40:00 11.6 0.8 13.3 9.5 11.7 0.8 13.3 9.5 11.5 1 13.7 9.1 140 6 145 165 9.8 0 9.8 9.6 09/19/2006 06:50:00 11 0.9 13.3 8 11.1 0.9 13 8.4 10.9 0.9 13 7.6 142 5 145 165 9.7 0 9.8 9.6 09/19/2006 07:00:00 11.6 0.9 14.1 8.4 11.6 0.9 14.5 8.8 11.2 1 13.7 8.4 141 6 142 165 9.6 0 9.8 9.6 09/19/2006 07:10:00 11.5 0.8 13.3 8.8 11.5 0.8 13.3 8.4 11.3 1.1 13.3 7.2 144 5 141 165 9.6 0 9.8 9.3 09/19/2006 07:20:00 10.5 0.9 13 8 10.5 0.9 13 7.6 10.4 1 13 8 146 5 140 165 9.6 0 9.8 9.3 09/19/2006 07:30:00 8.4 0.9 11.1 5.7 8.2 0.9 11.1 5.7 8.2 0.9 10.7 6.1 150 4 144 165 9.7 0 9.8 9.6 09/19/2006 07:40:00 6.8 0.3 8 6.1 6.7 0.3 8 5.7 7 0.4 8 6.1 152 4 149 165 9.6 0 9.8 9.3 09/19/2006 07:50:00 6.2 0.5 7.2 4.9 6 0.5 7.2 4.9 6.3 0.5 7.2 4.9 152 4 156 165 9.6 0 9.6 9.3 09/19/2006 08:00:00 5 0.4 6.1 3.8 4.9 0.4 5.7 3.8 5.1 0.4 6.1 3.8 148 4 150 165 9.6 0 9.8 9.6 09/19/2006 08:10:00 5.1 0.3 5.7 4.2 4.9 0.3 5.7 3.8 5.2 0.3 5.7 4.6 151 3 153 165 9.7 0 9.8 9.3 09/19/2006 08:20:00 5.1 0.8 6.8 3 4.9 0.8 6.8 3 5.1 0.8 6.8 3.4 144 7 145 165 9.8 0 10.1 9.3 09/19/2006 08:30:00 6.7 0.8 8.8 4.9 6.6 0.8 8.4 4.9 6.7 0.7 8.4 4.9 146 7 147 165 9.6 0.2 9.8 9 09/19/2006 08:40:00 8.5 0.8 10.3 6.1 8.4 0.9 10.7 6.5 8.5 0.9 10.7 6.5 145 3 147 165 9.7 0.1 9.8 9.3 09/19/2006 08:50:00 8.9 1 10.3 5.7 8.9 1 10.3 6.1 8.8 1 10.7 6.1 144 4 144 165 9.6 0.1 9.8 9.3 09/19/2006 09:00:00 7.6 0.6 8.8 6.5 7.7 0.6 9.1 6.5 7.5 0.6 9.1 6.1 142 5 142 165 9.7 0.1 10.1 9.3 09/19/2006 09:10:00 7.7 0.5 9.1 6.5 7.8 0.5 9.5 6.5 7.6 0.5 9.1 6.1 142 4 147 165 9.6 0.2 10.1 9 09/19/2006 09:20:00 8.1 0.7 9.9 6.1 8.1 0.8 10.3 6.1 7.9 0.8 9.9 6.1 142 5 144 165 9.7 0.1 9.8 9.3 09/19/2006 09:30:00 8.5 0.6 10.3 7.2 8.6 0.6 10.3 7.2 8.6 0.6 10.3 6.1 144 4 142 165 9.6 0.2 9.8 9 09/19/2006 09:40:00 7.6 0.5 9.1 6.5 7.5 0.5 9.1 6.5 7.6 0.6 9.1 5.3 145 5 147 165 10.1 0.3 10.6 9.3 09/19/2006 09:50:00 8.5 0.7 9.9 6.8 8.4 0.7 9.9 6.8 8.6 0.7 10.3 6.8 142 5 144 165 10.1 0.1 10.6 9.8 09/19/2006 10:00:00 9.2 0.5 10.3 7.6 9.2 0.5 10.3 7.6 9.2 0.7 10.3 6.8 145 3 145 165 9.9 0 10.3 9.6 09/19/2006 10:10:00 8.4 0.5 9.5 6.8 8.3 0.5 9.5 6.5 8.4 0.5 9.5 6.8 145 5 144 165 9.9 0.2 10.3 9.3 09/19/2006 10:20:00 8.5 0.5 9.5 6.8 8.4 0.5 9.5 6.8 8.5 0.5 9.9 7.2 143 4 143 165 10.1 0.1 10.6 9.6 09/19/2006 10:30:00 7.7 0.5 8.8 6.5 7.6 0.5 9.5 6.5 7.6 0.6 9.1 5.7 139 5 136 165 9.7 0.1 10.1 9.3 09/19/2006 10:40:00 7.7 0.7 9.5 5.7 7.6 0.7 9.5 5.7 7.6 0.8 9.5 5.7 140 6 143 165 9.6 0.1 10.1 9.3 09/19/2006 10:50:00 7.9 0.8 9.9 5.7 7.8 0.8 9.5 5.7 7.9 0.9 9.5 5.7 141 5 140 165 9.6 0.2 10.1 9 09/19/2006 11:00:00 7.2 0.7 8.8 4.9 7.1 0.7 8.8 4.9 6.9 0.8 8.8 4.2 134 7 123 165 9.7 0.1 10.1 9 09/19/2006 11:10:00 5.9 0.8 7.6 4.2 5.8 0.8 7.6 3.4 5.8 0.9 8 3 135 8 134 165 9.8 0.1 10.3 9.3 09/19/2006 11:20:00 6.5 0.7 8 4.6 6.5 0.7 8.4 4.6 6.4 0.8 8 4.6 131 8 128 165 9.8 0 10.1 9.6 09/19/2006 11:30:00 6.2 0.7 7.6 3.8 6.1 0.7 7.6 3.8 6.2 0.7 8 4.2 139 8 142 165 10 0.1 10.3 9.6 09/19/2006 11:40:00 5.4 0.5 6.5 3.8 5.3 0.5 6.5 3.4 5.4 0.6 6.8 3.8 136 7 135 165 10.3 0.1 10.9 9.8 09/19/2006 11:50:00 5.2 0.6 6.8 2.6 5.1 0.6 6.8 2.6 5.3 0.5 7.2 3.8 140 10 138 165 10.8 0.1 11.1 10.3 09/19/2006 12:00:00 4.8 0.7 7.6 3.4 4.6 0.7 7.2 3 4.9 0.7 7.2 3 148 10 142 165 11 0 11.4 10.6 09/19/2006 12:10:00 4.9 0.5 6.1 3.8 4.6 0.5 6.1 3.4 5 0.5 6.1 3.8 144 7 152 165 11.1 0 11.1 10.6 09/19/2006 12:20:00 5.2 0.4 6.5 4.2 5 0.4 6.1 3.8 5.3 0.4 6.1 4.2 145 5 143 165 10.8 0.1 11.1 10.3 09/19/2006 12:30:00 4.9 0.5 6.1 3.4 4.7 0.5 6.1 3.4 4.9 0.5 6.5 3.8 142 8 150 165 10.8 0 11.1 10.3 09/19/2006 12:40:00 5.3 0.3 6.1 4.6 5.1 0.3 5.7 4.2 5.3 0.4 6.1 4.2 146 5 148 165 10.7 0 11.1 10.6 09/19/2006 12:50:00 4.6 0.4 5.3 3.8 4.4 0.4 5.3 3.4 4.6 0.4 5.3 3 143 5 145 165 10.5 0 10.9 10.3 09/19/2006 13:00:00 4 0.5 5.3 2.6 3.8 0.5 4.9 2.6 4 0.5 5.3 3 142 6 142 165 10.6 0.1 10.9 10.3 09/19/2006 13:10:00 3.6 0.4 4.9 2.6 3.4 0.4 4.6 2.6 3.7 0.4 4.9 2.6 128 9 130 165 10.9 0.1 11.4 10.6 09/19/2006 13:20:00 3.9 0.5 5.7 2.6 3.7 0.5 5.7 2.3 4 0.4 5.7 3 135 7 135 165 11.3 0.1 11.7 10.9 09/19/2006 13:30:00 4 0.4 5.3 3 3.8 0.4 4.9 3 4 0.4 4.9 3 138 6 135 165 10.9 0 11.1 10.9 09/19/2006 13:40:00 4 0.4 5.3 2.6 3.8 0.5 4.9 2.3 4 0.4 5.7 3 138 9 157 165 11.1 0.2 11.7 10.9 09/19/2006 13:50:00 3.5 0.6 5.7 2.3 3.3 0.7 5.7 1.9 3.7 0.6 6.1 2.6 130 8 134 165 11.8 0.1 12.2 11.4 09/19/2006 14:00:00 3.4 0.6 4.9 1.9 3.1 0.7 4.9 1.5 3.5 0.6 4.9 1.9 138 11 142 165 12 0.2 12.5 11.7 09/19/2006 14:10:00 2.9 0.6 4.2 1.9 2.7 0.6 4.6 1.1 3.1 0.5 4.6 1.9 135 13 161 165 12.3 0.2 12.7 11.9 09/19/2006 14:20:00 3.8 0.6 5.3 2.3 3.5 0.7 5.3 1.9 3.9 0.6 5.7 1.9 149 12 143 165 12.4 0.1 12.7 11.9 09/19/2006 14:30:00 3.4 0.6 4.9 1.9 3 0.6 4.6 1.5 3.5 0.6 5.3 1.9 146 12 158 165 12.2 0 12.7 11.9 09/19/2006 14:40:00 3.4 0.6 4.9 1.9 3.2 0.6 5.3 1.5 3.6 0.6 5.7 2.3 141 10 138 165 12.5 0.1 13 12.2 09/19/2006 14:50:00 3.2 0.5 4.6 2.3 2.8 0.5 4.6 1.5 3.3 0.4 4.2 2.3 140 10 148 165 11.7 0.3 12.5 11.4 09/19/2006 15:00:00 1.8 0.7 3.4 0.4 1.4 0.7 3.4 0.4 2 0.7 3.4 0.4 140 29 126 165 11.3 0.1 11.7 11.1 09/19/2006 15:10:00 0.4 0.2 1.9 0.4 0.4 0.1 1.1 0.4 0.6 0.3 1.9 0.4 179 26 154 165 11.4 0 11.7 11.1 09/19/2006 15:20:00 0.8 0.5 2.3 0.4 0.6 0.4 1.9 0.4 0.9 0.6 2.3 0.4 278 33 321 165 11.5 0 11.7 11.4 09/19/2006 15:30:00 2.4 0.5 3.8 1.1 1.9 0.6 3.8 0.4 2.5 0.5 3.4 1.1 345 26 334 165 11.7 0 11.9 11.7 09/19/2006 15:40:00 4.2 1.1 6.1 1.5 4.1 1.2 6.1 1.1 4 1.2 5.7 1.5 325 15 334 165 11.7 0 11.9 11.4 09/19/2006 15:50:00 6.4 1 8.8 4.2 5.8 1.4 8.8 2.6 6 0.8 8 4.2 336 19 313 165 11.3 0.1 11.7 10.9 09/19/2006 16:00:00 5.9 0.6 7.6 3.8 4.5 1.1 7.6 2.3 5.8 0.6 7.2 4.2 354 7 356 165 10.8 0.2 11.1 10.6 09/19/2006 16:10:00 5.1 1 8 3.4 4.7 1 8.4 2.3 5.1 0.9 8.4 3 340 10 354 165 10.6 0 10.9 10.6 09/19/2006 16:20:00 4.5 1.5 7.2 1.9 4.3 1.5 7.2 1.5 3.7 1 6.5 1.5 308 20 296 165 10.9 0 11.1 10.6 09/19/2006 16:30:00 5.7 0.6 7.2 4.2 5.5 0.6 7.2 3.8 4.9 0.7 6.5 3.4 307 6 307 165 10.9 0 11.1 10.9 09/19/2006 16:40:00 7.6 1.6 11.5 4.9 7.5 1.6 11.5 4.6 6.5 1.7 11.1 3.4 308 9 312 165 10.8 0 11.1 10.9 09/19/2006 16:50:00 10.8 1.5 15.3 7.2 10.6 1.5 14.9 6.5 9.8 1.7 14.1 6.1 316 9 313 165 10.2 0.2 10.9 9.6 09/19/2006 17:00:00 9.8 1.3 13.7 6.8 9.7 1.3 13.3 6.8 9.4 1.5 14.1 6.1 317 8 319 165 10.1 0 10.3 9.6 09/19/2006 17:10:00 9.2 1.1 12.6 6.1 9.1 1.1 11.8 6.1 8.4 1.1 11.8 6.1 314 9 305 165 10.1 0.2 10.6 9.6 09/19/2006 17:20:00 11 1.2 14.1 8 10.8 1.1 13.3 7.6 10.7 1.3 14.5 7.2 320 7 331 165 10.3 0.1 10.6 9.8 09/19/2006 17:30:00 10.5 1 13.7 8.4 10.3 0.9 13.3 8 10 1.1 13 6.5 319 7 318 165 10.3 0.2 10.9 9.8 09/19/2006 17:40:00 7.8 1.2 11.1 5.3 7.7 1.1 10.7 4.9 7.3 1.3 10.3 4.2 317 8 314 165 10.4 0.1 10.9 9.8 09/19/2006 17:50:00 7.2 1 9.5 4.6 7.1 1 9.5 4.6 6.6 1 9.1 4.2 314 8 305 165 10.5 0.2 10.9 10.1 09/19/2006 18:00:00 6.9 1 9.1 4.9 6.8 1 8.8 4.6 6.2 1 9.1 3.8 310 8 317 165 10.5 0.2 10.9 10.1 09/19/2006 18:10:00 6.7 1.1 9.1 4.2 6.6 1.1 9.5 4.2 5.3 0.9 8.4 3.4 303 7 302 165 10.5 0 10.9 9.8 09/19/2006 18:20:00 6 0.7 7.6 3.4 5.9 0.7 7.6 3 4.7 0.7 6.8 2.6 300 7 303 165 10.5 0 10.9 10.1 09/19/2006 18:30:00 5.4 0.8 7.6 3.4 5.3 0.9 7.6 3 4.5 0.9 7.2 2.6 298 8 304 165 10.4 0 10.6 9.8 09/19/2006 18:40:00 4.4 0.7 6.5 2.6 4.4 0.8 6.8 2.6 4.2 0.8 6.1 1.9 282 8 286 165 10.4 0 10.9 10.1 09/19/2006 18:50:00 5.9 1 8.4 3.8 5.8 1 8.4 3.4 5 0.9 8 2.6 288 9 292 165 10.4 0 10.6 9.8 09/19/2006 19:00:00 6.2 1 8.8 4.6 6.2 1 9.1 4.2 5.6 1.3 9.1 3.4 290 9 278 165 10.5 0 10.9 10.3 09/19/2006 19:10:00 5.9 1.1 8.4 3.4 5.9 1.1 8.4 3.8 5.5 1.1 8.4 3.4 283 7 286 165 10.3 0 10.6 10.3 09/19/2006 19:20:00 6.3 0.8 8.4 3.8 6.5 0.7 8.4 4.6 6.1 0.8 8.4 3.8 279 7 273 165 10.3 0 10.6 10.3 09/19/2006 19:30:00 6.5 0.8 8.4 4.2 6.6 0.8 8.8 4.9 6.1 0.8 8 4.2 279 6 277 165 10.5 0 10.6 10.3 09/19/2006 19:40:00 5.5 1 7.2 3.4 5.6 0.9 7.2 3.4 5.4 0.9 7.2 3.4 278 5 282 165 10.6 0.1 10.9 10.3 09/19/2006 19:50:00 4.8 0.8 6.8 3 5 0.7 6.8 3 4.7 0.6 6.1 2.6 278 6 288 165 10.7 0 10.9 10.6 09/19/2006 20:00:00 5.2 1.1 9.5 2.3 5.5 1 9.5 2.6 4.9 0.9 8 3 281 11 290 165 10.7 0 10.9 10.3 09/19/2006 20:10:00 7 1.1 9.9 3.8 7.1 1.1 9.5 3.8 6.3 1.2 9.9 3.4 285 11 284 165 10.7 0 11.1 10.6 09/19/2006 20:20:00 5.5 0.9 8 3.8 5.3 0.9 8 3.4 4.4 1 6.5 2.3 303 10 299 165 10.5 0 10.9 10.3 09/19/2006 20:30:00 5 0.9 7.2 2.6 4.8 0.9 7.2 1.5 4.6 1 6.8 1.9 309 10 322 165 10.2 0 10.6 10.1 09/19/2006 20:40:00 6.1 1 8.4 3.4 5.9 1 8 3 5.1 1 8.8 2.6 297 10 308 165 10.3 0 10.6 9.8 09/19/2006 20:50:00 5.6 1 8 3.4 5.4 1 7.6 3.4 4.8 1 7.6 3 304 12 321 165 10.3 0 10.6 10.1 09/19/2006 21:00:00 7.6 1 9.9 4.9 7.4 1 9.9 4.9 6.4 1.2 8.8 3.8 308 7 307 165 10.2 0 10.6 10.1 09/19/2006 21:10:00 7.9 1 10.3 5.7 7.9 1.1 10.7 5.7 6.8 1.2 10.3 4.2 299 11 284 165 10.2 0.1 10.6 9.6 09/19/2006 21:20:00 9.7 1.2 13 6.8 9.7 1.2 12.6 6.8 7.7 1.3 12.6 4.6 300 8 310 165 10.1 0 10.3 9.6 09/19/2006 21:30:00 8.4 1.3 11.8 5.3 8.4 1.3 11.5 4.9 6.8 1.1 9.9 4.6 301 8 295 165 10 0 10.3 9.8 09/19/2006 21:40:00 8.4 1.3 12.2 5.3 8.4 1.2 11.8 5.3 6.9 1.1 11.5 4.2 300 9 288 165 10.1 0 10.6 9.8 09/19/2006 21:50:00 7.2 1.2 10.7 4.6 7.2 1.2 10.7 4.9 5.9 1.2 9.5 3.4 300 9 299 165 10.1 0 10.3 9.8 09/19/2006 22:00:00 9.5 1.2 12.2 6.5 9.5 1.2 12.2 6.5 7.9 1.5 12.2 4.6 305 8 304 165 10.1 0 10.6 9.8 09/19/2006 22:10:00 9 1.2 13 6.1 9 1.2 13 5.7 7.4 1.2 11.8 4.6 302 9 298 165 10.1 0 10.3 9.8 09/19/2006 22:20:00 8.8 1.4 12.2 6.1 8.7 1.5 12.2 6.1 6.9 1.3 10.3 4.2 298 7 300 165 10.1 0.1 10.6 9.6 09/19/2006 22:30:00 10.1 1.1 13 7.2 10.1 1.1 13 8 7.9 1 11.8 5.7 298 7 297 165 10.1 0.1 10.6 9.6 09/19/2006 22:40:00 11.1 0.9 14.1 8.8 11 0.9 13.3 8.8 8.6 1.1 11.8 6.1 297 6 290 165 10.3 0 10.9 10.1 09/19/2006 22:50:00 10.5 1.2 14.1 8 10.4 1.2 14.5 8 8.2 1.3 12.2 5.3 301 7 305 165 10.3 0 10.9 10.1 09/19/2006 23:00:00 10.1 1.1 13 7.6 10 1.1 13.3 7.6 8.2 1.3 12.2 5.3 303 7 300 165 10.5 0 10.9 10.3 09/19/2006 23:10:00 9.1 1.2 11.8 6.1 9.1 1.1 11.5 5.7 8.2 1.3 12.6 5.7 311 9 313 165 10.5 0 10.9 10.3 09/19/2006 23:20:00 10.9 1.3 14.1 7.6 10.8 1.3 14.1 7.6 8.9 1.3 12.6 6.1 306 7 310 165 10.6 0 10.9 10.3 09/19/2006 23:30:00 11.7 1.5 14.9 7.2 11.6 1.5 14.5 7.6 9.7 1.6 14.9 6.1 306 7 293 165 10.5 0 11.1 10.3 09/19/2006 23:40:00 9.8 1.3 13 6.5 9.6 1.3 13 6.1 8.5 1.5 12.2 4.6 305 10 311 165 10.4 0 10.9 10.3 09/19/2006 23:50:00 9.8 1.2 13.3 6.8 9.7 1.2 13 6.8 8 1.2 12.2 5.7 303 8 310 165 10.5 0 10.9 10.1 09/20/2006 00:00:00 9.6 1.5 13.7 6.5 9.6 1.5 13.7 6.5 7.7 1.5 11.8 4.6 295 7 298 165 10.5 0 10.9 10.3 09/20/2006 00:10:00 8.5 1 12.2 6.1 8.4 1 11.8 6.1 6.7 1.1 9.9 4.2 302 7 301 165 10.3 0 10.6 10.1 09/20/2006 00:20:00 8.3 1 10.7 5.7 8.3 1 10.7 5.7 6.9 1.1 9.9 4.6 303 7 291 165 10.3 0 10.6 9.8 09/20/2006 00:30:00 8 1.1 11.1 5.3 7.9 1.1 11.1 5.7 6.7 1.1 9.9 4.2 306 7 296 165 10.2 0 10.6 9.8 09/20/2006 00:40:00 9.9 1.3 13 6.5 9.9 1.3 13 6.5 7.9 1.1 11.5 4.6 298 8 310 165 10.3 0 10.9 9.8 09/20/2006 00:50:00 9.4 1.3 13 6.1 9.3 1.3 12.6 5.7 8.2 1.5 12.2 4.6 306 9 305 165 10.4 0 10.6 10.1 09/20/2006 01:00:00 9.6 1.5 13 5.7 9.5 1.5 13 5.7 7.9 1.2 11.1 4.2 304 9 305 165 10.4 0 10.9 10.3 09/20/2006 01:10:00 7 1.2 9.5 4.2 6.9 1.1 9.5 4.6 5.7 1.1 8.4 3 305 10 305 165 10.3 0.1 10.9 9.8 09/20/2006 01:20:00 8 2.3 12.6 3.8 8 2.3 12.6 3.8 6.6 1.8 11.1 3 300 9 290 165 10.1 0.1 10.6 9.6 09/20/2006 01:30:00 9.7 1.8 14.1 4.6 9.6 1.8 14.1 4.6 7.9 1.5 12.2 4.6 304 8 286 165 10.3 0.1 10.9 9.8 09/20/2006 01:40:00 11.4 1.9 16.8 7.6 11.4 1.9 16.8 7.6 9.3 1.6 14.5 5.7 299 9 292 165 10.5 0.2 10.9 10.1 09/20/2006 01:50:00 12 2 16.4 6.8 11.9 2 16.4 6.8 9.8 1.7 14.5 6.1 303 9 301 165 10.3 0 10.9 10.1 09/20/2006 02:00:00 12.3 1.9 16.8 8.4 12.2 1.9 16.8 8.4 10 1.7 14.5 6.8 299 8 287 165 10.4 0.1 10.9 10.3 09/20/2006 02:10:00 10.9 1.5 16.1 8 10.7 1.5 16.4 7.6 8.7 1.6 15.3 5.7 302 7 286 165 10.4 0 10.9 10.3 09/20/2006 02:20:00 10.6 1.4 15.3 7.6 10.5 1.4 15.3 7.2 8.5 1.3 12.6 5.7 301 8 310 165 10.1 0.1 10.6 9.8 09/20/2006 02:30:00 11.1 1.2 14.1 8 11 1.2 14.1 8 8.9 1.4 13.7 6.1 298 9 307 165 10.1 0.1 10.3 9.6 09/20/2006 02:40:00 10.9 1.4 15.6 8 10.8 1.4 15.3 7.2 9.1 1.4 13.7 6.1 301 9 301 165 10.3 0.1 10.6 9.8 09/20/2006 02:50:00 10.7 1.7 14.5 6.8 10.6 1.6 14.5 7.2 9.2 1.7 14.9 5.3 303 10 304 165 10.3 0.1 10.6 9.8 09/20/2006 03:00:00 11.3 2.2 16.4 6.1 11.2 2.1 16.8 5.7 9.3 1.6 14.9 5.7 304 9 306 165 10.2 0.1 10.6 9.8 09/20/2006 03:10:00 9.9 1.6 14.1 6.1 9.8 1.6 14.1 6.1 8.3 1.5 12.6 4.9 307 10 294 165 10.1 0.2 10.9 9.6 09/20/2006 03:20:00 8 2 14.9 4.2 8 2 14.5 4.2 6.8 1.7 13 3.4 303 10 294 165 10.1 0.1 10.6 9.6 09/20/2006 03:30:00 7.3 1.2 10.7 3.4 7.2 1.2 10.3 3.8 6.3 1.3 11.8 3.4 304 12 312 165 10.1 0.1 10.6 9.8 09/20/2006 03:40:00 8.7 2.3 15.3 3.4 8.6 2.2 14.9 3.8 7.5 2.1 13.7 3 306 9 305 165 10 0.2 10.9 9.6 09/20/2006 03:50:00 8 1.6 12.2 4.9 7.9 1.6 11.8 4.9 6.9 1.6 11.1 3.4 304 9 305 165 10 0.1 10.3 9.6 09/20/2006 04:00:00 5.9 0.7 8.4 4.2 5.8 0.7 8.4 4.2 5 0.9 7.6 3 295 12 301 165 9.8 0.1 10.3 9.3 09/20/2006 04:10:00 6.7 1.3 9.5 3.8 6.6 1.3 9.5 3.8 5.5 1.2 8.4 3 299 10 308 165 9.9 0.1 10.3 9.3 09/20/2006 04:20:00 6.7 1 9.5 4.2 6.7 1.1 9.1 4.2 6 1.4 9.5 3 293 14 271 165 9.8 0.1 10.1 9.3 09/20/2006 04:30:00 8 1.2 10.7 4.9 8.1 1.3 11.5 4.6 6.8 1.3 9.9 3.4 291 8 283 165 9.8 0.1 10.1 9.3 09/20/2006 04:40:00 8.2 1 10.3 4.9 8.3 0.9 10.3 5.7 7.5 1.2 10.3 4.6 286 8 289 165 9.8 0.1 10.1 9.3 09/20/2006 04:50:00 8.5 1.7 12.6 4.6 8.6 1.7 12.6 4.9 7.6 1.7 11.5 3.8 290 9 288 165 9.8 0.1 10.1 9.3 09/20/2006 05:00:00 9.2 1.5 13 5.7 9.2 1.5 13 5.7 7.9 1.5 11.8 5.3 293 8 289 165 9.7 0.1 10.1 9.3 09/20/2006 05:10:00 9.5 1 13 6.8 9.6 1 13 7.2 8.3 1.1 11.1 5.3 295 11 297 165 9.6 0.1 9.8 9.3 09/20/2006 05:20:00 9.1 1.1 12.2 6.8 9.1 1.1 12.2 6.8 7.6 1.2 11.5 4.6 293 8 295 165 9.6 0.1 9.6 9 09/20/2006 05:30:00 8.5 1.2 11.8 5.7 8.4 1.2 11.8 5.3 6.8 1.3 10.7 4.2 297 9 295 165 9.4 0 10.1 9 09/20/2006 05:40:00 9.5 1.8 13.7 4.2 9.5 1.9 13.7 3.4 8.1 1.7 12.6 3.4 293 7 294 165 9.4 0 9.6 9 09/20/2006 05:50:00 10.3 1.3 13.3 7.6 10.3 1.3 13.3 7.6 8.2 1.3 11.8 5.7 296 7 300 165 9.4 0 9.6 9 09/20/2006 06:00:00 11.5 1.5 14.9 8 11.5 1.5 14.9 7.6 9.5 1.5 13.7 6.1 295 8 292 165 9.4 0 9.6 9 09/20/2006 06:10:00 10.9 1.4 14.5 7.6 10.9 1.3 14.5 7.6 8.9 1.5 14.5 5.7 294 6 293 165 9.5 0 9.6 9.3 09/20/2006 06:20:00 9.6 1.6 13 5.3 9.6 1.7 13 5.7 7.7 1.6 12.2 4.6 302 8 308 165 9.4 0 9.6 9 09/20/2006 06:30:00 7.1 1.2 10.7 3.8 7.1 1.2 10.3 3.4 6 1.2 9.5 3.8 297 12 299 165 9.2 0 9.3 9 09/20/2006 06:40:00 6.9 1.1 10.3 4.2 6.8 1.1 9.9 4.2 5.9 1.2 9.1 3 306 12 316 165 9.3 0 9.6 9 09/20/2006 06:50:00 8.9 2 14.1 4.2 8.8 2 14.5 4.2 7.3 1.7 11.8 3 299 12 291 165 9.3 0 9.6 8.8 09/20/2006 07:00:00 8 1.1 11.5 4.9 7.9 1.2 11.1 4.9 6.7 1.2 10.3 4.2 304 9 301 165 9.3 0 9.6 9 09/20/2006 07:10:00 6.4 1.5 11.1 3 6.5 1.5 11.1 3.4 5.5 1.5 11.1 2.3 292 16 307 165 9.3 0 9.6 9 09/20/2006 07:20:00 5.2 1.4 10.7 1.9 5.3 1.5 11.1 2.3 4.7 1.6 11.5 1.9 285 15 282 165 9.3 0 9.6 9 09/20/2006 07:30:00 1.9 1 4.6 0.4 1.6 1 4.9 0.4 1.8 0.9 5.3 0.4 203 82 313 165 9.4 0 9.6 9 09/20/2006 07:40:00 1.1 0.7 3 0.4 0.8 0.5 2.6 0.4 1 0.6 2.3 0.4 320 69 344 165 9.5 0 9.6 9 09/20/2006 07:50:00 3.2 1.6 9.5 0.4 3.2 1.7 9.1 0.4 3.4 1.5 9.1 0.4 270 23 256 165 9.7 0 10.1 9.3 09/20/2006 08:00:00 1.5 0.7 3.4 0.4 1.1 0.8 3 0.4 1.7 0.7 3.8 0.4 266 58 230 165 9.9 0 10.1 9.3 09/20/2006 08:10:00 4 2 8.4 0.4 3.9 2 8 0.4 3.7 1.7 8.4 0.4 286 22 325 165 9.9 0.2 10.3 9.3 09/20/2006 08:20:00 7 1.3 11.1 3.8 6.9 1.3 11.1 3.8 6.1 1.3 10.3 3 304 15 305 165 9.7 0.2 10.1 9 09/20/2006 08:30:00 6.7 1.5 10.7 3.8 6.6 1.5 10.3 3.8 5.7 1.5 10.3 2.6 301 14 290 165 9.9 0.3 10.3 9.3 09/20/2006 08:40:00 6.6 1.6 13.3 3 6.7 1.5 12.6 3.8 6.1 1.5 10.3 2.6 288 15 291 165 10.1 0.2 10.6 9.6 09/20/2006 08:50:00 6.5 1.9 11.5 1.1 6.4 2.1 11.8 0.7 5.8 1.8 11.1 2.3 308 17 289 165 10 0.1 10.6 9.6 09/20/2006 09:00:00 8.7 1.5 13.3 4.2 8.6 1.5 12.6 4.9 7.5 1.5 12.2 3.8 302 12 309 165 10 0.2 10.3 9.6 09/20/2006 09:10:00 9.9 1.8 14.5 5.7 9.9 1.8 14.5 5.3 8.2 1.7 13 3.8 300 12 307 165 10.1 0.1 10.6 9.6 09/20/2006 09:20:00 7 1.4 11.1 3.4 7 1.4 10.7 3.4 5.8 1.5 10.7 2.3 294 16 298 165 10.2 0 10.6 9.8 09/20/2006 09:30:00 9.1 2.1 14.9 3.8 9 2.1 14.9 3.8 7.6 2.2 13.3 3.4 295 11 279 165 10.2 0 10.6 10.1 09/20/2006 09:40:00 9.2 1.6 13.7 5.7 9.1 1.6 13 5.7 7.8 1.7 12.6 4.2 301 10 310 165 10.3 0 10.6 10.1 09/20/2006 09:50:00 13.3 1.8 17.9 8.4 13.3 1.9 17.6 8 10.5 1.8 15.6 6.8 296 7 301 165 10.5 0.2 11.1 10.3 09/20/2006 10:00:00 13.4 1.5 16.8 8 13.4 1.5 16.8 8.4 10.7 1.6 15.6 6.8 295 6 291 165 10.8 0.1 11.1 10.6 09/20/2006 10:10:00 11.2 1.5 15.6 6.8 11.1 1.5 16.1 6.8 9.4 1.6 15.6 6.5 303 10 285 165 10.5 0 10.9 10.6 09/20/2006 10:20:00 12.5 1.3 15.6 8.8 12.4 1.4 15.6 8.4 9.9 1.3 14.5 7.2 303 7 300 165 10.3 0 10.6 10.3 09/20/2006 10:30:00 13.7 1.5 16.8 9.9 13.7 1.5 16.8 9.9 10.8 1.6 15.3 7.2 297 7 296 165 10.2 0 10.6 10.1 09/20/2006 10:40:00 13.7 1.3 16.8 9.9 13.6 1.3 16.4 10.3 10.7 1.5 15.3 7.6 303 7 314 165 10.3 0.1 10.9 10.1 09/20/2006 10:50:00 13.6 1.7 18.7 9.9 13.6 1.7 17.9 9.9 10.5 1.7 17.6 7.2 299 6 291 165 10.8 0.1 11.1 10.6 09/20/2006 11:00:00 12.7 1.4 17.2 9.1 12.6 1.4 17.2 9.5 10.1 1.5 14.9 6.1 300 7 307 165 10.9 0.3 11.7 10.3 09/20/2006 11:10:00 13.3 1.6 16.4 8.8 13.2 1.6 17.2 8.8 10.9 1.8 16.1 7.6 297 9 307 165 11.5 0 11.7 10.9 09/20/2006 11:20:00 14.9 1.5 17.9 10.7 14.8 1.5 17.9 10.7 11.9 1.9 17.9 8.4 303 7 310 165 11.5 0 11.7 11.1 09/20/2006 11:30:00 14.3 1.3 17.6 11.1 14.3 1.4 17.6 10.7 11.1 1.5 16.4 7.6 298 7 296 165 11.6 0 11.9 11.4 09/20/2006 11:40:00 14.7 1.3 17.9 11.1 14.7 1.4 18.3 11.1 11.9 1.7 16.8 8 294 6 291 165 11.5 0 11.7 11.4 09/20/2006 11:50:00 13 1.1 15.3 9.9 13 1.1 15.3 9.9 10.3 1.5 14.9 7.2 295 6 297 165 11.8 0.1 11.9 11.7 09/20/2006 12:00:00 12 1.1 14.5 9.1 12 1.1 14.1 7.6 9.6 1.3 13 6.8 297 8 309 165 11.9 0 12.2 11.7 09/20/2006 12:10:00 12.4 1.3 16.1 9.1 12.4 1.3 15.6 9.1 10.1 1.5 14.1 6.5 299 8 297 165 12 0 12.2 11.9 09/20/2006 12:20:00 11.8 1.1 14.9 8.4 11.8 1.1 14.9 8.8 9.7 1.5 13 6.1 296 9 291 165 12.2 0 12.5 11.9 09/20/2006 12:30:00 11.9 1.1 14.5 8 12 1.1 14.5 8.4 11.1 1.5 14.9 8 288 9 292 165 12.1 0 12.5 11.9 09/20/2006 12:40:00 12.7 1.1 15.3 9.1 12.8 1.1 15.3 9.5 11.5 1.9 14.9 7.2 287 7 277 165 12.2 0 12.5 11.9 09/20/2006 12:50:00 10.6 1.8 14.5 6.8 10.6 1.9 14.9 6.5 9.4 2.5 14.9 4.9 292 11 280 165 12.6 0.3 13.3 12.2 09/20/2006 13:00:00 11.2 1.5 14.5 6.1 11.1 1.4 14.9 6.1 9.2 1.4 12.6 5.7 304 8 307 165 13.1 0.2 13.5 12.7 09/20/2006 13:10:00 11.6 1.2 14.9 7.2 11.5 1.3 15.3 7.2 9.6 1.5 13.3 6.1 300 9 312 165 12.7 0 12.7 12.5 09/20/2006 13:20:00 11.6 1.3 14.9 8.4 11.5 1.3 14.5 8.4 9.4 1.3 12.6 6.5 301 7 300 165 12.5 0.1 12.7 12.5 09/20/2006 13:30:00 11.3 1.3 14.9 7.6 11.3 1.2 14.9 7.6 9.6 1.5 13 6.1 296 8 302 165 12.4 0.1 12.7 12.2 09/20/2006 13:40:00 10.7 1.3 14.5 7.6 10.6 1.3 14.5 6.8 8.9 1.3 12.2 6.1 301 9 292 165 12.5 0.2 13 12.2 09/20/2006 13:50:00 11.5 1.6 15.3 6.8 11.4 1.5 14.9 7.6 9.5 1.6 14.5 6.1 303 8 285 165 12.9 0 13 12.7 09/20/2006 14:00:00 11.8 1.4 16.1 7.6 11.7 1.4 15.6 8 9.2 1.2 13 6.1 303 5 295 165 12.7 0 12.7 12.5 09/20/2006 14:10:00 11.4 1.7 14.9 7.2 11.3 1.6 14.9 7.6 9.2 1.6 13.7 6.1 301 8 294 165 12.9 0 13.3 12.7 09/20/2006 14:20:00 10.6 1.3 15.3 6.8 10.6 1.3 14.9 6.8 8.8 1.5 13 5.3 300 9 304 165 13 0 13.5 12.7 09/20/2006 14:30:00 12.9 1.9 18.3 9.1 12.8 1.9 18.3 8.8 10.2 1.4 14.5 6.8 304 7 298 165 12.8 0 13.3 12.5 09/20/2006 14:40:00 12.6 1.2 15.3 9.5 12.6 1.2 15.6 9.5 10.2 1.6 15.6 6.5 295 8 301 165 12.5 0 13 12.5 09/20/2006 14:50:00 14.4 1.3 17.9 11.1 14.4 1.3 17.9 11.1 11 1.5 16.4 8 299 6 292 165 12.5 0 13 12.5 09/20/2006 15:00:00 14.9 1 17.2 11.8 14.9 1.1 17.2 12.2 11.7 1.5 15.6 8.4 304 6 302 165 12.5 0 12.7 12.5 09/20/2006 15:10:00 12 1.6 16.4 8.4 11.9 1.6 16.1 8.4 9.6 1.4 14.1 6.8 304 5 303 165 12.7 0 13 12.5 09/20/2006 15:20:00 10.6 1.4 13.7 7.6 10.5 1.4 13.7 7.6 8.4 1.1 11.5 5.7 304 7 298 165 13.1 0.1 13.5 13 09/20/2006 15:30:00 9.5 1.2 11.8 5.7 9.5 1.2 11.8 6.1 7.8 1.3 11.1 4.6 298 9 301 165 13.1 0.1 13.5 12.7 09/20/2006 15:40:00 8.8 1.2 12.6 6.1 8.8 1.2 12.2 5.7 7.2 1.1 10.3 4.2 299 8 292 165 13.1 0 13.3 13 09/20/2006 15:50:00 10.8 1.7 15.3 7.2 10.8 1.7 15.3 7.2 8.7 1.8 14.9 4.9 300 9 283 165 13 0.1 13.5 12.7 09/20/2006 16:00:00 12.6 1.2 15.3 9.5 12.5 1.2 15.3 9.5 10.4 1.5 14.1 6.8 298 8 293 165 12.5 0 12.7 12.5 09/20/2006 16:10:00 12.4 1.1 15.3 8.8 12.3 1.1 14.9 8.4 10 1.5 13.3 6.5 306 7 313 165 12.6 0 12.7 12.5 09/20/2006 16:20:00 12.9 1 15.3 10.3 12.8 1 15.3 10.3 11.3 1.1 14.5 8.4 309 5 307 165 12.5 0 12.7 12.5 09/20/2006 16:30:00 11.7 1.5 14.9 7.2 11.7 1.5 14.9 7.2 9.2 1.3 12.2 5.7 303 6 302 165 12.4 0 12.7 12.2 09/20/2006 16:40:00 8 1.7 12.2 4.2 8 1.7 12.2 3.8 6.8 1.7 11.1 3.4 294 8 291 165 12.7 0 13 12.5 09/20/2006 16:50:00 5.4 1.2 8.8 2.3 5.5 1.1 8.8 2.6 4.7 1 8 1.9 296 12 310 165 13.2 0 13.5 13 09/20/2006 17:00:00 7.6 0.9 9.9 4.9 7.6 0.8 9.5 4.9 6.4 1.1 9.1 3.8 305 7 307 165 12.8 0 13 12.7 09/20/2006 17:10:00 5.8 1.5 9.1 2.6 5.8 1.4 8.8 2.6 4.8 1.5 8.4 1.5 302 13 323 165 13.1 0 13.3 12.7 09/20/2006 17:20:00 4.9 1.2 8 2.6 4.9 1.3 8 2.6 4 1.2 8.4 1.5 295 13 290 165 13.1 0.1 13.3 12.7 09/20/2006 17:30:00 6 1 8.8 3.8 6.1 1 8.8 3.8 5.5 1.2 8 2.6 286 9 285 165 12.5 0.1 12.7 12.2 09/20/2006 17:40:00 6.4 1 8.8 3.8 6.4 1 9.1 3.8 5.7 1.2 8.4 3.4 288 9 293 165 12.2 0 12.5 11.9 09/20/2006 17:50:00 4.6 0.9 6.8 2.6 4.7 0.9 6.8 2.6 4.1 1 6.5 1.9 293 11 277 165 12.3 0.1 12.5 12.2 09/20/2006 18:00:00 4.4 0.9 6.5 2.3 4.5 0.9 6.5 2.3 3.8 0.8 6.1 2.3 303 15 294 165 12.4 0 12.7 12.2 09/20/2006 18:10:00 4.8 0.9 6.8 2.6 4.8 1 6.8 2.6 4.3 0.7 6.1 2.3 307 8 305 165 12.1 0 12.5 11.9 09/20/2006 18:20:00 4 0.6 5.3 2.6 4 0.6 5.3 2.6 3.7 0.6 5.3 2.3 308 8 307 165 11.9 0.1 12.2 11.4 09/20/2006 18:30:00 5.2 0.6 6.8 4.2 5.3 0.6 7.2 4.2 4.3 0.6 6.5 3 302 7 293 165 11.5 0 11.7 11.4 09/20/2006 18:40:00 4.8 0.4 5.7 3.8 4.9 0.4 5.7 3.8 3.8 0.5 5.7 2.6 298 5 300 165 11.2 0 11.4 10.9 09/20/2006 18:50:00 5.6 0.6 6.8 3.8 5.7 0.6 6.8 4.2 4.2 0.6 5.7 3 300 5 303 165 10.7 0.2 11.1 10.1 09/20/2006 19:00:00 6 0.4 7.2 4.6 6.2 0.5 7.2 4.9 4.7 0.7 6.8 3.4 295 6 294 165 10.3 0.1 10.6 10.1 09/20/2006 19:10:00 5.6 0.6 6.8 4.2 5.7 0.6 6.8 4.6 4.7 0.8 6.8 2.3 291 4 290 165 10.1 0 10.3 9.8 09/20/2006 19:20:00 5.5 0.5 6.5 4.2 5.5 0.6 6.8 4.2 4.2 0.6 5.7 2.6 303 4 302 165 9.8 0.1 10.3 9.6 09/20/2006 19:30:00 6 0.4 6.8 4.6 6.1 0.4 6.8 4.6 4.4 0.6 6.1 3 296 4 296 165 9.7 0 10.1 9.6 09/20/2006 19:40:00 5.2 0.5 6.8 3.4 5.3 0.6 6.8 3.4 4.4 0.7 6.8 2.3 293 4 292 165 10 0 10.3 9.6 09/20/2006 19:50:00 5.1 0.4 6.1 3.4 5.1 0.4 6.1 3 3.7 0.5 5.3 2.6 296 4 298 165 10 0 10.3 9.6 09/20/2006 20:00:00 4.5 0.4 5.3 3.4 4.5 0.4 5.3 3.4 3.9 0.6 5.3 2.3 291 4 295 165 10.1 0.1 10.3 9.6 09/20/2006 20:10:00 4.7 0.4 5.7 3.8 4.7 0.4 5.7 3.8 3.8 0.6 5.3 2.6 293 4 292 165 10.1 0.1 10.3 9.8 09/20/2006 20:20:00 4.5 0.3 5.3 3.4 4.4 0.3 5.3 3.4 4.3 0.5 5.3 3 286 4 285 165 10.1 0 10.3 9.6 09/20/2006 20:30:00 4.2 0.4 4.9 3 4.1 0.4 5.3 3 4 0.6 5.7 2.3 283 5 286 165 10.1 0.1 10.6 9.8 09/20/2006 20:40:00 3.7 0.5 4.6 2.3 3.6 0.5 4.6 2.3 3.2 0.5 4.2 1.9 290 5 290 165 10.5 0.1 10.9 9.8 09/20/2006 20:50:00 3.5 0.3 4.2 2.6 3.5 0.3 4.2 2.6 3.1 0.5 4.2 1.9 290 6 285 165 10.5 0 10.9 10.3 09/20/2006 21:00:00 3.1 0.4 3.8 1.9 2.9 0.4 3.8 1.9 2.6 0.5 3.8 1.5 293 8 286 165 10.3 0 10.6 9.8 09/20/2006 21:10:00 2.2 0.8 3.8 0.7 1.8 1 3.8 0.4 1.9 0.7 3.4 0.4 288 6 301 165 10.3 0 10.6 9.6 09/20/2006 21:20:00 1.4 0.5 2.6 0.4 1 0.6 2.3 0.4 1.3 0.6 2.3 0.4 272 8 272 165 10.3 0.1 10.6 9.8 09/20/2006 21:30:00 1.9 0.3 2.6 1.1 1.5 0.3 2.3 0.7 2 0.3 2.6 1.1 279 5 284 165 10 0.1 10.3 9.6 09/20/2006 21:40:00 1.9 0.9 3.4 0.4 1.8 0.8 3.4 0.7 2.1 0.7 3.4 1.1 272 8 282 165 9.8 0.1 10.3 9.3 09/20/2006 21:50:00 2.5 0.6 3.8 0.7 2.4 0.5 3.4 1.5 2.8 0.4 3.4 1.9 270 7 281 165 9.6 0.2 10.1 9.3 09/20/2006 22:00:00 2.8 0.6 4.2 1.1 3 0.8 4.6 1.5 3.3 0.8 4.6 2.3 268 3 265 165 9.7 0.1 10.1 9.3 09/20/2006 22:10:00 2.5 0.4 4.2 1.5 2.6 0.5 4.2 1.1 3.2 0.5 4.6 2.3 256 6 255 165 9.5 0.2 9.8 9 09/20/2006 22:20:00 2.1 0.4 3 1.1 1.9 0.5 3 0.7 2.4 0.4 3.8 1.5 239 12 230 165 9.6 0.1 9.8 9.3 09/20/2006 22:30:00 3.2 0.4 4.2 2.3 3 0.5 4.2 1.9 3.7 0.4 4.6 3 236 8 249 165 9.3 0.2 9.8 8.8 09/20/2006 22:40:00 2.7 0.3 3.4 1.9 2.4 0.4 3.4 1.5 3.1 0.3 3.8 2.3 228 4 227 165 9.2 0.2 9.6 8.8 09/20/2006 22:50:00 1.5 0.5 2.6 0.4 1 0.6 2.6 0.4 1.8 0.5 3 0.7 228 11 225 165 9.5 0.3 10.1 8.8 09/20/2006 23:00:00 1.5 0.5 2.6 0.4 1 0.5 2.3 0.4 1.6 0.5 2.6 0.4 207 15 190 165 9.8 0.1 10.1 9.3 09/20/2006 23:10:00 0.8 0.4 1.9 0.4 0.4 0.2 1.1 0.4 1.1 0.4 2.3 0.4 198 15 182 165 9.6 0.1 10.3 9 09/20/2006 23:20:00 0.5 0.3 1.5 0.4 0.4 0.1 0.7 0.4 0.9 0.4 1.9 0.4 214 18 176 165 9.8 0 10.1 9.6 09/20/2006 23:30:00 0.7 0.4 1.5 0.4 0.4 0.2 1.1 0.4 1 0.4 1.9 0.4 224 9 219 165 10 0 10.3 9.3 09/20/2006 23:40:00 1.2 0.5 2.3 0.4 0.8 0.5 1.9 0.4 1.4 0.5 2.3 0.4 212 9 211 165 9.9 0 10.1 9.6 09/20/2006 23:50:00 2.5 0.4 3.4 1.5 2.2 0.4 3 1.5 2.7 0.4 3.8 1.9 198 7 192 165 9.6 0 10.3 9.3 09/21/2006 00:00:00 2.7 0.4 3.8 1.9 2.4 0.4 3.4 1.5 2.9 0.3 3.8 1.9 195 9 190 165 9.8 0 9.8 9.6 09/21/2006 00:10:00 2.5 0.3 3.4 1.9 2.2 0.4 3.4 1.5 2.7 0.3 3.4 1.9 196 8 179 165 9.7 0 9.8 9.6 09/21/2006 00:20:00 2.3 0.4 3 1.5 2 0.4 3 1.1 2.6 0.4 3.8 1.5 191 8 176 165 9.7 0 9.8 9.6 09/21/2006 00:30:00 2.5 0.4 4.2 1.9 2.2 0.5 4.2 1.5 2.7 0.6 4.2 1.5 193 16 192 165 9.5 0 9.6 9.3 09/21/2006 00:40:00 2 0.6 3 0.4 1.6 0.7 3 0.4 2.4 0.5 3.4 1.1 191 14 204 165 9.3 0.1 9.6 8.8 09/21/2006 00:50:00 1.4 0.5 3 0.4 0.9 0.6 3 0.4 1.7 0.4 3.4 1.1 171 7 178 165 9.1 0 9.6 8.8 09/21/2006 01:00:00 1.7 0.6 3 0.4 1.2 0.6 2.6 0.4 1.8 0.6 2.6 0.4 190 20 166 165 9 0 9.3 8.5 09/21/2006 01:10:00 2.3 0.5 3 1.1 2 0.5 3 0.7 2.4 0.4 3.4 1.5 185 6 193 165 8.9 0 9 8.5 09/21/2006 01:20:00 2.4 0.4 3.4 1.5 2.1 0.4 3 1.1 2.7 0.4 3.8 1.9 185 7 178 165 8.6 0 8.8 8.3 09/21/2006 01:30:00 2.1 0.5 3.8 0.7 1.7 0.6 3.4 0.4 2.2 0.3 3 1.5 175 18 115 165 8.7 0 8.8 8.3 09/21/2006 01:40:00 1.4 0.4 2.6 0.4 1 0.5 2.3 0.4 1.7 0.3 2.3 0.7 162 10 190 165 8.9 0 9 8.5 09/21/2006 01:50:00 1.2 0.6 3 0.4 0.7 0.5 2.6 0.4 1.4 0.3 2.3 0.7 155 11 123 165 8.8 0 9 8.5 09/21/2006 02:00:00 1.4 0.5 2.6 0.4 1 0.5 2.3 0.4 1.5 0.4 2.3 0.4 143 8 148 165 8.7 0 9 8.3 09/21/2006 02:10:00 2.6 0.3 3 1.5 2.3 0.4 3 1.1 2.6 0.4 3.4 1.5 166 5 165 165 8.5 0.1 8.8 7.8 09/21/2006 02:20:00 3 0.3 3.8 2.6 2.8 0.4 3.8 1.9 3.1 0.3 3.8 2.6 162 7 158 165 8.1 0 8.3 7.5 09/21/2006 02:30:00 3.4 0.5 4.9 2.3 3.4 0.6 5.3 1.9 3.4 0.5 4.9 2.3 142 12 129 165 8.1 0 8.5 7.5 09/21/2006 02:40:00 4.9 1.1 7.6 1.9 4.9 1.1 7.6 1.9 4.7 1 6.8 2.6 124 8 122 165 8.4 0.1 8.8 7.8 09/21/2006 02:50:00 6.8 0.8 8.4 4.9 6.9 0.8 8.8 4.9 6.7 1 9.1 4.2 122 6 128 165 8.7 0 9 8 09/21/2006 03:00:00 8 0.5 9.5 6.5 8.1 0.5 9.5 6.8 7.7 0.6 9.1 5.7 118 4 116 165 8.7 0 9 8.5 09/21/2006 03:10:00 8.4 0.5 9.5 6.1 8.5 0.5 9.9 6.5 8 0.6 9.1 5.3 116 3 114 165 8.7 0 9 8.5 09/21/2006 03:20:00 8.6 0.5 9.9 6.8 8.8 0.5 9.9 7.2 8.2 0.7 9.5 6.1 116 3 116 165 8.7 0 8.8 8.3 09/21/2006 03:30:00 8.5 0.4 9.5 6.8 8.7 0.4 9.5 6.8 8.1 0.6 9.5 6.1 116 2 112 165 8.6 0.1 8.8 8.3 09/21/2006 03:40:00 7.6 0.4 8.4 6.5 7.8 0.4 8.8 6.5 7.2 0.7 8.4 4.6 115 3 114 165 8.7 0 8.8 8.3 09/21/2006 03:50:00 6.9 0.5 8 5.3 7 0.5 8.4 5.3 6.7 0.6 8 4.6 120 4 116 165 8.7 0 8.8 8.3 09/21/2006 04:00:00 5.9 0.4 6.8 4.6 6 0.4 7.2 4.9 5.8 0.4 6.8 4.6 123 3 119 165 8.5 0.1 8.8 8.3 09/21/2006 04:10:00 6.1 0.6 7.6 4.2 6.1 0.6 8 4.2 5.9 0.7 7.6 3 120 5 116 165 8.5 0.1 8.8 8 09/21/2006 04:20:00 5.8 0.8 7.6 4.2 5.7 0.7 7.2 3.8 5.8 0.8 7.2 3.8 129 10 136 165 8.5 0.1 8.8 8 09/21/2006 04:30:00 6.7 0.7 8.4 4.6 6.7 0.6 8.4 4.6 6.6 0.7 8 4.6 120 12 126 165 8.5 0.1 8.5 8 09/21/2006 04:40:00 6.1 0.5 7.6 4.9 6.1 0.6 7.6 4.6 6.1 0.5 7.2 4.6 130 6 129 165 8.5 0.1 8.8 8 09/21/2006 04:50:00 5.6 0.6 7.2 4.2 5.5 0.6 6.8 4.2 5.4 0.6 6.8 3.8 135 8 130 165 8.4 0.2 8.5 8 09/21/2006 05:00:00 4.4 0.6 5.7 3 4.2 0.6 5.7 2.6 4.4 0.6 5.7 3 151 7 133 165 8.4 0.1 8.5 8 09/21/2006 05:10:00 4.1 0.5 5.7 3 3.9 0.5 4.9 2.6 4.1 0.5 5.3 3 153 12 158 165 8.3 0 8.5 7.8 09/21/2006 05:20:00 3.8 0.4 4.9 2.6 3.6 0.5 4.6 2.3 3.7 0.4 4.9 3 145 9 157 165 8 0.1 8.3 7.5 09/21/2006 05:30:00 5.2 1 7.6 3 5.1 1 7.6 3 5.3 1 7.6 3.4 143 6 151 165 7.9 0 8 7.3 09/21/2006 05:40:00 4.9 0.9 7.2 3 4.7 0.9 7.2 2.6 4.7 0.9 7.2 3 152 9 154 165 7.9 0.1 8 7.5 09/21/2006 05:50:00 4.7 0.4 6.1 3.8 4.6 0.4 6.1 3.8 4.8 0.4 6.1 4.2 157 5 156 165 8 0.1 8.3 7.5 09/21/2006 06:00:00 4.9 0.4 6.1 3.8 4.8 0.5 5.7 3.4 4.8 0.4 5.7 3.8 148 4 143 165 8 0.1 8.3 7.5 09/21/2006 06:10:00 4.8 0.5 6.1 3.8 4.6 0.5 5.7 3.4 4.6 0.5 6.1 3.8 150 4 152 165 8.1 0 8.3 7.5 09/21/2006 06:20:00 4.8 0.4 6.1 3.8 4.6 0.4 6.1 3.4 4.7 0.4 5.7 3.8 146 7 141 165 8.1 0 8.3 7.8 09/21/2006 06:30:00 5.6 0.5 6.5 3.8 5.5 0.5 6.5 3.8 5.4 0.6 6.8 3.4 140 6 140 165 8.2 0 8.5 7.5 09/21/2006 06:40:00 6.1 0.5 7.6 4.9 6.1 0.5 7.6 4.9 6 0.5 7.6 4.9 140 4 139 165 8.1 0 8.3 7.5 09/21/2006 06:50:00 6 0.4 7.2 4.6 5.9 0.4 7.2 4.6 5.9 0.5 6.8 4.2 142 4 144 165 8 0 8.3 7.5 09/21/2006 07:00:00 5.9 0.4 6.8 4.9 5.9 0.4 6.8 4.9 5.9 0.4 6.8 4.6 142 3 145 165 8 0 8.3 7.5 09/21/2006 07:10:00 5.9 0.4 7.2 4.9 5.9 0.3 6.8 4.9 6 0.4 7.2 4.9 143 4 141 165 8.1 0 8.3 7.5 09/21/2006 07:20:00 5.8 0.4 6.5 4.9 5.8 0.4 6.8 4.9 5.6 0.4 6.5 4.2 137 4 138 165 8 0.1 8.3 7.5 09/21/2006 07:30:00 6.3 0.6 8.4 4.9 6.2 0.7 8.4 4.9 6.2 0.7 8 4.6 139 5 140 165 8 0.2 8.3 7.5 09/21/2006 07:40:00 7.4 0.6 9.1 5.3 7.4 0.6 9.5 5.7 7.4 0.7 8.8 4.9 139 6 133 165 8 0.2 8.3 7.3 09/21/2006 07:50:00 7.6 0.8 9.1 4.9 7.6 0.8 8.8 4.9 7.6 0.8 9.1 5.3 141 6 144 165 7.9 0.2 8.3 7.3 09/21/2006 08:00:00 7.5 0.6 9.1 5.7 7.5 0.6 9.1 6.1 7.4 0.7 9.1 5.3 139 6 136 165 7.8 0.2 8.3 7.3 09/21/2006 08:10:00 7.8 0.4 8.8 6.5 7.8 0.5 8.8 6.5 7.8 0.5 8.8 6.5 140 4 136 165 7.6 0.2 7.8 7 09/21/2006 08:20:00 7.1 0.6 8.4 4.9 7.2 0.6 8.4 4.9 7.1 0.6 8.4 5.3 141 5 141 165 7.7 0.2 8 7.3 09/21/2006 08:30:00 6.8 0.7 8.8 5.3 6.9 0.7 8.4 4.9 6.7 0.7 8.8 4.9 140 6 137 165 7.8 0.2 8 7.3 09/21/2006 08:40:00 7.9 0.8 9.5 6.1 7.9 0.8 9.5 5.7 7.7 0.8 9.5 5.3 134 6 122 165 7.8 0.2 8 7.3 09/21/2006 08:50:00 7.7 0.5 9.1 6.1 7.9 0.5 9.1 6.1 7.6 0.6 9.1 5.3 125 5 136 165 7.8 0.2 8 7 09/21/2006 09:00:00 7.6 0.9 10.3 5.3 7.8 0.9 10.3 5.3 7.3 1 9.9 4.6 121 7 124 165 7.7 0.1 8 7 09/21/2006 09:10:00 8.9 0.9 11.5 6.8 9.1 0.9 11.5 6.8 8.7 1 11.5 6.1 124 7 132 165 7.6 0 7.8 7 09/21/2006 09:20:00 9.1 0.8 11.1 6.8 9.3 0.8 11.5 6.8 8.7 0.8 11.1 6.5 122 7 110 165 7.7 0.1 8 7 09/21/2006 09:30:00 10.2 1.2 12.6 7.6 10.3 1.2 13 7.2 9.8 1.6 13.3 6.5 121 7 121 165 7.6 0.1 7.8 7 09/21/2006 09:40:00 10.8 0.9 13 8 10.9 0.9 13.3 8 10.6 1 13.3 8 130 6 138 165 7.3 0 7.5 7 09/21/2006 09:50:00 9.7 1.2 13 6.8 9.8 1.2 13.3 7.2 9.6 1.4 13 6.5 130 7 124 165 7.3 0 7.5 7.3 09/21/2006 10:00:00 9.6 1.1 13 6.1 9.8 1.1 13.3 6.5 9.4 1.1 11.8 6.5 119 5 105 165 7.3 0 7.5 7.3 09/21/2006 10:10:00 11.1 1.5 15.3 6.8 11.4 1.5 15.6 6.8 10.5 1.5 14.1 6.1 119 6 121 165 7.3 0 7.5 7 09/21/2006 10:20:00 11.7 1.5 15.6 7.6 12 1.5 16.1 8 11.5 1.5 16.4 8.4 125 6 126 165 7.3 0 7.5 7 09/21/2006 10:30:00 12.2 0.9 15.3 9.5 12.4 0.9 15.3 8.8 11.6 1.2 14.9 8 118 5 117 165 7.1 0 7.3 7 09/21/2006 10:40:00 12.7 1.5 16.4 9.1 12.9 1.5 16.4 9.5 11.9 1.5 15.6 8.4 115 6 110 165 7.2 0 7.3 7 09/21/2006 10:50:00 14.2 1.3 17.6 9.9 14.5 1.3 17.9 10.3 13.5 1.5 16.8 9.1 116 6 119 165 7.1 0 7.3 7 09/21/2006 11:00:00 13.1 1.3 16.8 9.1 13.3 1.4 16.8 9.1 12.4 1.5 16.8 8.4 121 7 112 165 7.2 0 7.5 7 09/21/2006 11:10:00 14 1.7 19.1 8.8 14.3 1.7 19.1 9.5 13.4 1.6 18.3 8.8 120 6 109 165 7.3 0 7.5 7.3 09/21/2006 11:20:00 15.3 1.3 18.7 11.5 15.6 1.3 19.5 11.8 14.7 1.5 18.3 11.1 118 5 112 165 7.3 0 7.5 7 09/21/2006 11:30:00 14.3 1.7 18.3 8.8 14.6 1.7 18.7 9.1 13.6 2 17.9 8.4 114 6 111 165 7.3 0 7.5 7 09/21/2006 11:40:00 14.1 1.5 17.9 9.5 14.4 1.5 17.9 9.9 13.1 1.6 17.2 8.8 115 7 136 165 7.4 0 7.5 7.3 09/21/2006 11:50:00 16.8 2.1 21 10.7 17.1 2.1 21.4 11.1 16.1 2.1 21 9.9 114 8 118 165 7.3 0 7.5 7 09/21/2006 12:00:00 15.9 2.3 22.1 8.8 16.2 2.3 23.3 9.1 14.8 2.3 22.6 9.1 108 7 106 165 7.2 0 7.5 7 09/21/2006 12:10:00 17.6 1.9 22.1 11.1 17.8 2 22.9 11.1 16.5 2.2 22.1 10.7 108 8 116 165 7.3 0 7.5 7 09/21/2006 12:20:00 18 2.6 23.3 10.3 18.3 2.7 23.7 9.9 16.7 2.6 22.9 10.3 107 7 107 165 7.1 0 7.3 7 09/21/2006 12:30:00 18.4 2.4 24.4 11.1 18.7 2.4 24.8 11.1 17.3 2.5 24.4 10.3 107 7 111 165 7.2 0 7.3 7 09/21/2006 12:40:00 19.1 2.6 24.8 10.7 19.4 2.6 25.2 10.3 17.8 2.7 24.8 10.3 108 7 98 165 7.3 0 7.5 7 09/21/2006 12:50:00 19.8 2.5 25.6 13 20.1 2.6 26.3 12.6 18.3 2.7 24.4 11.1 110 7 111 165 7.3 0 7.5 7.3 09/21/2006 13:00:00 20.2 2.5 25.2 13 20.5 2.6 25.2 12.2 18.7 2.8 24.4 12.2 109 6 112 165 7.4 0 7.5 7.3 09/21/2006 13:10:00 18.5 2.5 24.8 10.3 18.7 2.5 25.6 11.5 17.4 2.5 24.4 10.7 107 7 102 165 7.4 0 7.5 7.3 09/21/2006 13:20:00 19.8 2.4 26 12.2 20.1 2.5 26.3 12.2 18.7 2.6 24.8 12.2 102 7 110 165 7.5 0 7.8 7.5 09/21/2006 13:30:00 19 2.4 24.8 10.7 19.3 2.5 24.8 11.1 17.7 2.7 24 10.3 101 8 106 165 7.6 0 7.8 7 09/21/2006 13:40:00 18.4 2.6 25.6 10.7 18.7 2.6 26 11.1 17.5 2.5 23.7 10.7 101 8 91 165 7.6 0 7.8 7.3 09/21/2006 13:50:00 18 2.2 24 12.6 18.3 2.3 24 12.6 17 2.3 22.1 10.3 98 9 90 165 7.8 0 8 7.3 09/21/2006 14:00:00 18.2 2.7 25.2 11.1 18.6 2.7 25.2 11.1 17.2 2.6 23.7 10.3 101 9 99 165 7.9 0.1 8.3 7.5 09/21/2006 14:10:00 20 4 29.1 9.9 20.4 4 29.4 9.9 18.9 3.6 28.3 9.1 106 9 111 165 8.1 0 8.3 7.5 09/21/2006 14:20:00 19.7 3.2 26 11.8 20 3.2 26 11.1 18.2 3.1 24.4 11.5 103 8 108 165 8.1 0 8.5 7.5 09/21/2006 14:30:00 20.8 3.1 27.5 11.5 21.2 3.1 28.3 12.2 19.7 2.9 26.8 11.5 102 7 102 165 8.3 0 8.5 7.8 09/21/2006 14:40:00 19.7 2.8 25.6 9.9 20.1 2.8 26.3 9.1 18.5 3.1 26.8 10.7 107 8 110 165 8.5 0.1 8.5 7.8 09/21/2006 14:50:00 21.3 3.2 28.7 11.8 21.7 3.3 29.4 11.5 20.1 3.5 28.3 11.8 104 7 91 165 8.5 0 8.8 8.3 09/21/2006 15:00:00 21.5 2.7 27.1 14.1 21.8 2.8 27.9 14.1 20.2 2.9 26.3 13 109 7 87 165 8.7 0 9 8.3 09/21/2006 15:10:00 20.8 2.4 26.3 14.9 21.1 2.5 26.8 14.9 19.6 2.5 25.6 13.3 113 8 107 165 8.9 0 9 8.5 09/21/2006 15:20:00 21.3 2.4 27.1 13.7 21.6 2.5 27.5 14.9 20.3 2.6 26.8 12.6 117 8 108 165 9 0 9.3 8.8 09/21/2006 15:30:00 19 2.3 26 12.2 19.3 2.3 26.3 12.6 18.4 2.4 25.2 13 123 8 116 165 9.3 0 9.6 9 09/21/2006 15:40:00 20.8 2.2 26 14.5 21.1 2.2 26.3 14.5 20 2.4 26 12.2 120 7 121 165 9.6 0.1 9.8 9.3 09/21/2006 15:50:00 19 2.1 23.7 12.6 19.3 2.1 24 13 18.3 2.2 24 11.5 122 6 126 165 9.8 0 9.8 9 09/21/2006 16:00:00 19.4 2 25.6 14.5 19.7 2 26.3 14.5 19.3 1.9 24.8 14.5 132 7 132 165 10 0 10.3 9.3 09/21/2006 16:10:00 18.5 1.5 21.8 13.7 18.6 1.5 22.1 14.5 18.1 1.7 23.3 13 139 6 140 165 10 0.2 10.3 9.6 09/21/2006 16:20:00 16.9 1.3 19.9 13.3 17 1.3 20.2 13.3 16.7 1.4 20.2 12.6 143 6 138 165 10.1 0.2 10.3 9.6 09/21/2006 16:30:00 16.6 1.3 19.9 13.3 16.6 1.4 19.9 12.2 16.4 1.6 19.9 11.5 145 5 145 165 10 0.2 10.3 9.6 09/21/2006 16:40:00 16.1 1.5 19.9 13.3 16.1 1.5 19.9 13 15.8 1.6 19.5 11.5 146 5 151 165 10 0.1 10.3 9.6 09/21/2006 16:50:00 16.8 1.7 20.6 13 16.9 1.7 20.6 13 16.5 1.8 21.8 12.6 141 6 137 165 9.9 0.1 10.6 9.6 09/21/2006 17:00:00 17 1.7 20.6 12.6 17.1 1.7 20.6 12.6 16.6 2 21.4 11.1 144 6 145 165 9.8 0 10.1 9.6 09/21/2006 17:10:00 17.5 1.4 21.8 14.1 17.5 1.4 21.4 14.1 17 1.7 22.1 12.2 143 7 148 165 9.8 0.1 10.1 9.3 09/21/2006 17:20:00 18.1 1.5 21.8 14.1 18.2 1.5 22.1 14.5 18 1.5 21.8 13 144 5 148 165 9.8 0.1 10.1 9.3 09/21/2006 17:30:00 18.5 1.5 22.1 14.5 18.5 1.5 22.6 14.9 18.1 1.5 22.1 13.7 144 5 143 165 9.7 0 9.8 9 09/21/2006 17:40:00 18 1.7 22.6 14.5 18.1 1.7 22.9 14.1 17.5 1.7 22.1 13.7 142 7 138 165 9.7 0.1 9.8 9 09/21/2006 17:50:00 17.7 1.5 21.4 13 17.8 1.5 21.8 13 17.3 1.5 21.8 12.2 143 6 149 165 9.6 0.1 9.8 9 09/21/2006 18:00:00 16.9 1.5 20.6 12.6 17 1.5 20.6 12.6 16.4 1.7 19.5 10.7 140 7 145 165 9.6 0 9.8 9.6 09/21/2006 18:10:00 17.7 1.6 22.1 13.3 17.9 1.6 22.6 14.1 17.4 1.7 21.8 11.1 140 7 136 165 9.6 0 9.6 9.3 09/21/2006 18:20:00 18.6 1.5 22.9 15.3 18.7 1.5 23.3 15.3 18.3 1.8 22.9 13.3 142 6 132 165 9.4 0 9.6 9 09/21/2006 18:30:00 16.7 1.7 21.8 11.1 16.9 1.7 21.8 11.5 16.4 1.7 19.9 11.8 140 6 141 165 9.3 0 9.6 9 09/21/2006 18:40:00 15.6 1.1 17.9 11.5 15.7 1.2 17.9 11.8 15.5 1.1 17.9 12.2 143 5 139 165 9.2 0 9.6 9 09/21/2006 18:50:00 14.3 1.2 16.8 11.1 14.4 1.2 17.2 11.5 14 1.4 17.6 10.3 143 6 146 165 9.1 0 9.3 8.8 09/21/2006 19:00:00 12.2 1 14.9 8.8 12.3 1 14.9 9.1 11.8 1.2 14.5 9.1 140 7 150 165 9.1 0 9.3 9 09/21/2006 19:10:00 10.7 1 13 7.6 10.8 1 13.3 8 10.3 1.1 13 7.2 140 6 139 165 9 0 9.3 8.8 09/21/2006 19:20:00 9.1 1.1 11.5 6.1 9 1.2 11.5 5.7 9 1.2 11.5 6.1 144 6 151 165 9.1 0 9.3 8.8 09/21/2006 19:30:00 6.7 0.8 8.8 4.6 6.6 0.8 8.4 4.2 6.6 0.9 8.8 4.6 145 6 143 165 9.2 0 9.3 8.8 09/21/2006 19:40:00 4.4 0.5 6.1 3 4.4 0.5 6.1 3.4 4.5 0.5 6.1 2.6 152 7 146 165 9.2 0 9.3 9 09/21/2006 19:50:00 3 0.7 4.6 1.5 2.8 0.7 4.6 1.1 3.3 0.7 4.9 1.9 170 13 134 165 9.3 0 9.3 9 09/21/2006 20:00:00 1.5 0.5 2.6 0.7 1.5 0.5 2.6 0.7 1.7 0.3 2.6 1.1 213 15 238 165 9.2 0 9.3 9 09/21/2006 20:10:00 3.4 0.6 4.9 2.3 3.5 0.7 4.9 2.3 3.2 0.6 4.9 1.9 256 15 249 165 9 0 9.3 8.8 09/21/2006 20:20:00 5.5 0.3 6.5 4.6 5.8 0.4 6.5 4.9 5.1 0.5 6.1 3.8 286 4 292 165 9 0 9.3 8.8 09/21/2006 20:30:00 6.1 0.5 7.6 4.9 6.3 0.5 7.6 4.9 5.1 0.8 7.2 3.4 291 4 291 165 9 0 9 8.8 09/21/2006 20:40:00 8.1 1 10.3 5.7 8.2 1 10.3 5.7 7.2 1.3 10.7 4.2 287 5 278 165 9 0 9.3 8.8 09/21/2006 20:50:00 8.8 0.8 10.7 6.8 8.8 0.8 10.7 7.2 8.4 0.8 10.3 5.7 282 5 293 165 9.3 0 9.6 9 09/21/2006 21:00:00 6.9 1.2 11.1 4.2 7.6 1.1 11.1 4.6 7.4 1.2 10.3 4.9 276 9 274 165 9.6 0.1 9.8 9 09/21/2006 21:10:00 5.7 1.1 8.8 3 6.2 0.9 9.5 3.8 6 0.9 8 3.8 275 9 282 165 9.6 0 9.8 9.3 09/21/2006 21:20:00 4.7 2 10.3 0.4 4.7 2.1 10.3 0.4 4.5 1.5 9.1 1.1 246 41 293 165 9.7 0 10.1 9.3 09/21/2006 21:30:00 4 1.9 9.5 0.4 4.3 2.3 9.5 0.4 4.1 2.1 9.5 0.4 238 26 280 165 9.8 0 10.1 9.3 09/21/2006 21:40:00 6.7 1.4 10.3 3.4 7.8 1.5 12.6 4.2 7.3 1.5 11.5 3.8 256 11 260 165 10.1 0.1 10.6 9.6 09/21/2006 21:50:00 7.8 1.5 11.5 4.2 9.2 1.5 13.7 5.7 8.6 1.4 12.6 5.3 259 10 273 165 10.3 0 10.9 9.8 09/21/2006 22:00:00 10.9 1.9 18.7 7.2 11.8 1.9 18.7 7.6 11.3 1.7 18.7 6.5 275 8 279 165 10.3 0.3 10.9 9.6 09/21/2006 22:10:00 14.6 2.5 19.5 8 14.9 2.3 19.9 9.9 14.2 2.4 19.1 8 279 8 272 165 10 0.1 10.9 9.6 09/21/2006 22:20:00 9.9 1.6 14.1 5.3 11.3 1.7 15.3 6.5 10.4 1.7 14.9 4.9 270 12 275 165 9.8 0 10.3 9.3 09/21/2006 22:30:00 10 1.9 15.6 5.7 11.4 2.1 16.4 6.1 10.9 2 16.4 6.5 269 11 278 165 9.8 0 10.1 9.6 09/21/2006 22:40:00 12.6 3.1 19.1 6.1 14 2.8 21.4 7.6 13.2 2.9 19.9 7.2 270 11 271 165 9.8 0 10.1 9.3 09/21/2006 22:50:00 9.2 2.1 14.9 4.9 10.5 2.6 17.9 5.3 10.1 2.6 17.9 5.3 258 12 266 165 9.8 0.1 10.1 9.3 09/21/2006 23:00:00 9.7 1.9 16.1 6.1 10.7 1.7 16.1 7.6 9.8 1.7 14.9 6.1 252 10 249 165 9.7 0 10.1 9.3 09/21/2006 23:10:00 9.3 1.5 13.7 4.9 10 1.3 13.3 5.7 9.3 1.2 12.6 6.1 250 9 247 165 10 0.1 10.3 9.6 09/21/2006 23:20:00 8.8 1.8 14.1 5.3 8.9 1.8 13.3 5.3 8.2 1.5 12.2 5.7 243 8 246 165 10.2 0 10.6 9.6 09/21/2006 23:30:00 9.1 1.5 13.3 5.3 9.3 1.5 13.7 5.3 8.7 1.3 12.2 5.3 238 11 246 165 10.4 0.1 10.9 9.8 09/21/2006 23:40:00 10.1 1.9 15.3 4.9 10.2 1.8 15.3 4.9 9.6 2 14.9 4.6 233 10 236 165 10.7 0.1 11.1 10.3 09/21/2006 23:50:00 9.6 1.8 14.5 5.7 9.8 1.7 14.5 6.1 9.3 1.7 13.7 6.5 236 11 245 165 10.6 0.2 11.1 10.1 09/22/2006 00:00:00 9.5 1.5 13.3 5.3 9.6 1.5 13.3 5.3 9 1.5 12.6 5.7 225 9 238 165 10.5 0 10.9 9.8 09/22/2006 00:10:00 8.6 1.5 11.8 4.6 8.8 1.5 11.8 4.9 8 1.6 11.5 4.2 231 11 231 165 10.3 0.1 10.6 9.8 09/22/2006 00:20:00 6.8 1.5 10.7 2.6 7 1.5 10.7 3.4 6.5 1.3 10.7 3.4 229 16 230 165 10.3 0.1 10.6 9.8 09/22/2006 00:30:00 6.6 1.5 11.5 3.8 6.6 1.5 11.1 3.8 6.1 1.5 10.3 3 231 16 249 165 10.2 0.1 10.6 9.8 09/22/2006 00:40:00 8.4 2.1 13 4.2 8.3 2.1 13 4.6 7.9 2 11.8 4.2 234 12 246 165 10.2 0.1 10.6 9.6 09/22/2006 00:50:00 6.5 1.7 11.8 3 7.6 1.5 11.8 4.6 7.3 1.3 12.2 4.2 256 10 245 165 10.1 0.2 10.9 9.3 09/22/2006 01:00:00 6 1 8.8 3.4 7.4 1.2 10.3 4.6 6.9 1.1 9.5 3.8 262 9 284 165 9.9 0 10.3 9.6 09/22/2006 01:10:00 3.8 2.3 9.9 0.4 4.1 2.4 10.3 0.4 4 2.1 8.8 1.1 217 33 245 165 9.8 0.2 10.1 9.3 09/22/2006 01:20:00 6.6 2.4 11.1 1.1 6.7 2.3 11.1 1.5 6.5 2.1 10.7 1.9 195 16 199 165 9.3 0 9.6 9 09/22/2006 01:30:00 7.8 1.3 12.6 4.9 7.8 1.3 12.6 4.9 7.7 1.1 11.1 5.3 201 8 206 165 9 0.1 9.3 8.5 09/22/2006 01:40:00 6.8 1.7 10.7 3 6.9 1.7 10.7 3.4 6.4 1.7 11.5 2.6 208 10 200 165 8.9 0 9 8.5 09/22/2006 01:50:00 6.2 1.8 11.5 2.6 6.3 1.8 11.8 2.6 5.9 1.5 10.7 2.6 213 13 200 165 8.8 0 9 8.3 09/22/2006 02:00:00 6.3 1.5 9.9 2.6 6.3 1.5 9.9 2.6 5.9 1.5 9.9 2.3 210 15 204 165 8.8 0 9 8.5 09/22/2006 02:10:00 6.1 1.7 10.3 1.9 6.1 1.6 10.3 1.9 5.7 1.4 9.9 2.3 202 18 194 165 8.8 0 9 8.5 09/22/2006 02:20:00 7.5 1.3 11.1 3.8 7.6 1.3 10.7 4.2 7.3 1.3 11.1 4.2 213 11 203 165 8.8 0.1 9 8.5 09/22/2006 02:30:00 8.2 1.6 11.5 3 8.3 1.7 11.5 3.4 7.7 1.6 11.1 4.6 211 11 217 165 8.8 0 9 8.5 09/22/2006 02:40:00 9.4 1.2 13 5.3 9.5 1.3 12.6 5.7 8.9 1.5 13.7 4.6 208 8 207 165 8.8 0 9 8.5 09/22/2006 02:50:00 7.3 1.5 11.1 2.6 7.4 1.5 11.1 2.6 6.7 1.5 9.9 3 219 13 208 165 8.9 0.1 9 8.3 09/22/2006 03:00:00 6.4 1.6 9.9 2.3 6.4 1.6 10.3 2.6 5.8 1.4 9.1 2.3 225 12 221 165 8.9 0.1 9 8.5 09/22/2006 03:10:00 5 2 8.4 0.4 5.1 2 8.4 0.4 4.8 1.9 9.1 0.4 231 22 223 165 9 0.2 9.6 8.5 09/22/2006 03:20:00 3.7 1.7 8.4 0.4 3.8 1.7 8.4 0.4 3.6 1.4 7.6 0.4 252 24 251 165 9.2 0.1 9.6 8.8 09/22/2006 03:30:00 5.5 1.1 8 3 6.3 1.2 9.1 3.8 5.9 1.1 8.8 3.4 270 11 262 165 9.9 0.2 10.3 9.3 09/22/2006 03:40:00 6.3 1.3 11.1 3 6.7 1.4 11.5 3.4 6.2 1.3 9.5 3.4 279 9 276 165 10.1 0 10.3 9.6 09/22/2006 03:50:00 6.7 1.5 11.1 3.4 7.4 1.4 11.5 4.6 7 1.3 11.1 4.2 271 11 271 165 10.3 0 10.6 10.1 09/22/2006 04:00:00 7.2 1.6 11.8 3.8 7.9 1.6 11.5 4.6 7.5 1.6 11.1 4.2 255 11 254 165 10.1 0 10.3 9.8 09/22/2006 04:10:00 8.5 2.5 16.1 2.6 10 3.1 16.8 3.4 9.4 2.8 15.6 3.8 265 16 253 165 10.3 0 10.6 10.1 09/22/2006 04:20:00 6 1.6 11.5 1.9 6.7 1.6 13 2.6 6.2 1.3 11.5 3.4 270 14 289 165 10.2 0 10.6 9.8 09/22/2006 04:30:00 5.4 1 8 3 6 1 8.8 3 5.8 1 8.4 2.3 272 12 270 165 10.1 0 10.3 9.8 09/22/2006 04:40:00 5 1.5 11.1 2.3 6 1.3 11.1 3.4 5.5 1.3 10.7 3.4 264 12 274 165 10.1 0 10.6 9.8 09/22/2006 04:50:00 7.2 2.2 12.6 2.3 8.3 2.6 13 3 7.9 2.4 12.6 3.4 260 13 268 165 10.2 0 10.6 9.8 09/22/2006 05:00:00 7.2 1.7 11.5 3.4 8.3 1.7 12.6 3.8 8 1.6 12.2 4.6 265 12 272 165 10.3 0 10.6 9.8 09/22/2006 05:10:00 5.9 1.3 9.1 2.3 6.5 1.2 9.5 3 6.2 1.2 9.5 3.8 250 12 246 165 10.3 0 10.6 9.8 09/22/2006 05:20:00 5.7 1.1 9.9 3.4 6.3 1.1 9.9 4.2 6.2 1 9.1 4.2 258 13 256 165 10.3 0 10.6 9.8 09/22/2006 05:30:00 5.3 1 8 3 6.3 1 9.9 4.2 6.1 0.9 9.9 4.2 263 8 268 165 10.2 0 10.6 9.8 09/22/2006 05:40:00 6.1 1.3 9.9 3.4 7.3 1.2 10.7 4.9 6.9 1.2 10.3 4.2 265 7 266 165 10.3 0.1 10.9 10.3 09/22/2006 05:50:00 5.6 1.1 8 2.6 6.4 1.2 10.3 3.4 6.2 1.2 9.5 3.4 272 8 259 165 10.3 0.1 10.9 9.8 09/22/2006 06:00:00 6.6 1.5 9.9 3 7.1 1.2 10.3 4.2 6.7 1.2 9.9 3.4 276 7 278 165 10.2 0 10.6 9.8 09/22/2006 06:10:00 8.9 1.2 12.2 6.1 9.5 1.4 14.9 6.8 9.1 1.4 13.7 6.1 275 9 277 165 10.3 0 10.9 10.1 09/22/2006 06:20:00 8.7 1.5 13 5.7 9.4 1.6 14.9 5.7 8.9 1.5 13.7 5.3 276 8 280 165 10.2 0.1 10.9 9.8 09/22/2006 06:30:00 8.2 1.1 11.1 4.9 8.9 1.2 11.5 6.1 8.4 1.2 11.1 5.7 277 8 287 165 10.1 0 10.6 9.8 09/22/2006 06:40:00 8.5 1 11.1 4.9 9 1.1 11.5 5.7 8.6 1.1 11.5 5.3 276 6 276 165 10.2 0 10.6 9.8 09/22/2006 06:50:00 7.1 1.4 10.3 3.4 7.6 1.3 10.3 4.2 7.3 1.2 9.9 4.2 276 8 284 165 10.1 0 10.6 9.8 09/22/2006 07:00:00 10.1 2.1 16.1 5.7 10.7 2 16.4 7.2 10.1 2.3 16.4 4.9 277 9 274 165 10.3 0 10.6 9.8 09/22/2006 07:10:00 11.8 1.3 15.3 8 12.3 1.3 15.6 9.1 11.7 1.5 15.6 7.6 279 7 275 165 10.2 0 10.6 9.8 09/22/2006 07:20:00 12.8 1.4 16.4 8.8 13.4 1.3 16.8 9.5 12.8 1.4 16.4 8.8 279 7 274 165 10.2 0.1 10.6 9.8 09/22/2006 07:30:00 14.2 1.7 17.9 9.1 14.5 1.6 17.9 9.1 13.7 1.9 17.9 8.8 280 7 278 165 10.1 0 10.6 9.8 09/22/2006 07:40:00 15.4 1.3 17.9 10.7 15.6 1.4 18.7 11.5 14.8 1.7 18.7 9.1 281 5 282 165 10.1 0 10.9 9.8 09/22/2006 07:50:00 15.2 1.4 18.3 11.5 15.4 1.3 18.7 11.8 14.6 1.7 17.9 9.5 281 6 276 165 10.1 0 10.6 9.8 09/22/2006 08:00:00 15.4 1.7 19.5 10.7 15.6 1.7 19.5 10.7 13.9 2.1 18.7 8 284 7 296 165 10.1 0.2 10.6 9.6 09/22/2006 08:10:00 16.2 1.4 19.5 12.2 16.4 1.4 19.5 12.2 15.5 1.8 20.2 10.3 282 5 282 165 10.3 0.2 10.6 9.6 09/22/2006 08:20:00 15.1 1.7 18.7 8.4 15.4 1.6 19.1 10.7 14.8 1.6 18.3 9.9 279 6 284 165 10.3 0.1 10.6 9.8 09/22/2006 08:30:00 13.9 1.7 17.6 9.5 14.2 1.6 17.9 9.9 13.7 1.7 17.6 7.6 279 7 274 165 10.5 0.2 10.9 10.1 09/22/2006 08:40:00 13.3 1.9 16.8 7.2 13.5 1.8 16.8 8.8 12.9 1.9 17.2 8 279 6 278 165 10.4 0.1 10.9 10.1 09/22/2006 08:50:00 11.2 2.1 16.8 6.1 11.8 2 16.4 7.2 11.3 2 16.4 6.1 277 8 286 165 10.6 0.2 10.9 10.3 09/22/2006 09:00:00 11.2 1.7 14.9 6.8 11.6 1.7 15.3 7.6 11.2 1.7 15.3 6.8 279 8 284 165 10.7 0.1 10.9 10.3 09/22/2006 09:10:00 10 1.3 14.1 6.8 10.4 1.3 13.7 7.2 9.7 1.4 13 6.1 280 9 282 165 10.7 0.1 11.1 10.3 09/22/2006 09:20:00 9.5 1.5 13.3 6.5 10.4 1.4 13.7 6.8 9.7 1.5 13.3 4.2 274 9 285 165 10.8 0 11.1 10.6 09/22/2006 09:30:00 9.9 1.6 13.3 5.7 10.4 1.5 13.7 5.3 10 1.5 13 6.5 278 9 277 165 10.7 0 10.9 10.6 09/22/2006 09:40:00 9.4 1.9 13.7 4.9 10 1.6 14.1 5.7 9.6 1.6 13.7 5.3 276 9 288 165 10.9 0 11.1 10.3 09/22/2006 09:50:00 8.6 1.5 12.2 5.3 9.4 1.2 12.6 6.1 8.6 1.4 11.8 4.9 276 9 277 165 11 0 11.4 10.3 09/22/2006 10:00:00 7.2 1.2 9.9 4.2 8.1 1.1 10.7 5.3 7.8 1 10.3 4.9 272 9 287 165 11.3 0.1 11.7 10.3 09/22/2006 10:10:00 6.7 1.2 9.9 3.4 7.7 1.1 11.1 5.3 7.4 1 9.9 4.9 269 10 278 165 11.7 0 11.9 11.4 09/22/2006 10:20:00 6.5 1.2 9.5 4.2 7.3 1 9.9 4.6 7 1 9.9 4.6 271 9 275 165 11.9 0 12.2 11.4 09/22/2006 10:30:00 5.2 1.5 8.8 2.3 5.8 1.5 8.8 3 5.5 1.4 8.8 3 266 16 285 165 12.3 0.1 12.5 11.7 09/22/2006 10:40:00 5.3 1.2 8.8 3 5.6 1.1 8.4 3 5.2 1.2 8.4 1.9 274 16 271 165 12.6 0 12.7 12.2 09/22/2006 10:50:00 3.9 1.9 9.5 1.1 4.4 2.2 11.1 1.1 4.2 2.2 9.9 1.1 266 22 286 165 13.3 0.4 13.8 12.2 09/22/2006 11:00:00 6.3 1.1 10.3 3.8 6.5 1.3 10.7 3.8 6.2 1.7 10.3 3 284 15 280 165 13.5 0.2 14.1 13 09/22/2006 11:10:00 6.8 1.4 10.3 2.6 7 1.3 9.9 3.4 6.5 1.3 9.5 3.4 283 16 281 165 13 0.2 13.8 12.5 09/22/2006 11:20:00 8.2 1.8 13 4.2 8.6 1.7 13 4.6 7.9 1.9 13.3 3.8 279 13 304 165 12.7 0 12.7 12.5 09/22/2006 11:30:00 6.8 1.4 10.7 3 7.2 1.4 11.1 4.2 7 1.4 10.7 3.8 275 13 297 165 12.8 0.3 13.5 12.5 09/22/2006 11:40:00 6.8 1.5 10.3 3 7.7 1.8 11.8 3.4 7.4 1.8 11.5 2.6 272 12 275 165 13.7 0.2 14.4 13.3 09/22/2006 11:50:00 6.2 1.2 8.8 3.4 6.5 1.1 9.5 3.8 6.4 1.2 9.1 3.8 277 11 269 165 14 0.2 14.4 13.5 09/22/2006 12:00:00 6.6 0.9 9.5 3.8 7.3 1.1 11.1 4.9 7.2 1.1 10.3 4.6 269 9 273 165 14.1 0 14.6 13.8 09/22/2006 12:10:00 6.4 1.1 9.1 3.4 6.7 1.2 9.9 3.8 6.3 1.3 9.1 3.4 276 11 271 165 14.4 0 15.2 14.4 09/22/2006 12:20:00 6.1 1.4 9.9 2.6 6.5 1.3 10.3 3.4 6.3 1.3 9.9 3.4 274 12 278 165 14.7 0.3 15.5 13.8 09/22/2006 12:30:00 7 1.1 9.9 4.6 7.9 1 11.1 5.3 7.5 1 11.1 4.9 271 10 256 165 13.5 0.1 14.1 13.3 09/22/2006 12:40:00 6.9 0.9 9.1 3 6.9 0.9 9.1 3.4 6.5 1.1 9.1 3.8 284 9 270 165 13.3 0.1 13.8 13 09/22/2006 12:50:00 5.8 1 8 3.4 6 1 8.4 3.8 5.7 1.1 8.4 3 280 8 297 165 13 0 13.3 12.7 09/22/2006 13:00:00 5.6 1 7.6 3 6.4 0.7 8 3.8 6.2 0.7 8.4 3.4 268 9 278 165 13 0.1 13.3 13 09/22/2006 13:10:00 4.8 0.8 6.8 2.6 5 0.8 6.8 2.6 4.6 0.9 6.8 2.6 286 11 291 165 12.9 0 13 12.7 09/22/2006 13:20:00 5.1 1 8 2.6 5 1 7.6 1.9 4.6 1 7.2 2.3 309 8 319 165 13.1 0 13.5 13 09/22/2006 13:30:00 4.2 1 6.8 1.9 4.2 1 7.2 1.5 4 1 6.1 1.9 288 11 285 165 13.4 0 13.5 13.3 09/22/2006 13:40:00 4.2 1 7.2 1.9 4.6 1.1 7.2 2.3 4.6 1.1 7.2 2.3 266 15 292 165 13.2 0 13.3 13 09/22/2006 13:50:00 3.8 1 6.5 1.9 4.1 1 6.5 1.9 3.9 1 6.1 1.5 277 16 277 165 13.4 0 13.5 13.3 09/22/2006 14:00:00 3.9 0.6 5.3 2.3 3.8 0.7 5.7 2.3 3.3 0.6 5.7 1.9 299 10 307 165 13.6 0 13.8 13.3 09/22/2006 14:10:00 2.9 1.5 7.2 0.4 3 1.5 7.2 0.4 2.9 1.3 6.1 0.4 275 15 295 165 13.4 0.2 13.8 13 09/22/2006 14:20:00 6.7 2 12.2 3 6.8 2 12.2 2.6 6 2 12.2 3 290 12 291 165 12.9 0 13 12.7 09/22/2006 14:30:00 6.6 1.4 9.9 3.4 6.5 1.4 9.5 3.4 5.5 1.1 8.4 2.6 297 11 303 165 12.5 0 12.7 12.5 09/22/2006 14:40:00 6.1 1 8.4 3.4 6 1 8.4 3 5.1 0.9 7.6 2.6 304 9 297 165 12.5 0 12.7 12.5 09/22/2006 14:50:00 5.4 0.9 8 3.4 5.6 1 8 3.4 5.2 1.1 8.4 2.6 289 14 309 165 12.5 0 12.7 12.5 09/22/2006 15:00:00 5.3 1.4 8.8 2.3 5.3 1.5 9.1 2.6 4.9 1.4 8.4 1.9 285 8 282 165 12.6 0 12.7 11.9 09/22/2006 15:10:00 3 0.7 4.9 1.1 3.1 0.7 4.9 1.5 3.3 0.6 4.9 1.9 254 26 282 165 12.7 0 12.7 12.5 09/22/2006 15:20:00 3.4 0.9 6.1 1.1 3.3 1 5.7 0.7 3.6 0.8 5.7 1.5 217 17 206 165 12.7 0 13 12.5 09/22/2006 15:30:00 3.9 0.9 6.5 1.5 3.8 1 6.5 1.1 3.9 1 6.5 1.5 216 15 208 165 12.6 0 12.7 12.5 09/22/2006 15:40:00 5.6 1.1 7.6 3 5.7 1.1 8 2.6 5.7 1 8.8 3 215 8 216 165 12.1 0.1 12.5 11.9 09/22/2006 15:50:00 4.3 0.9 6.5 2.3 4.3 1 6.5 1.5 4.3 0.9 6.5 2.6 219 12 215 165 12.1 0 12.2 11.7 09/22/2006 16:00:00 3.5 1.2 5.7 1.1 3.4 1.2 6.1 0.7 3.7 1.1 6.5 1.1 237 15 232 165 12 0 12.5 11.9 09/22/2006 16:10:00 0.7 0.5 2.3 0.4 0.5 0.4 1.9 0.4 1.1 0.4 2.3 0.4 252 17 286 165 12.5 0 12.7 12.2 09/22/2006 16:20:00 1.4 0.6 3 0.4 1 0.6 2.3 0.4 1.9 0.5 3 0.7 223 22 200 165 12.7 0 12.7 12.2 09/22/2006 16:30:00 2 0.8 3.4 0.4 1.8 0.8 3.4 0.4 2.3 0.6 3.8 0.7 240 13 238 165 12.4 0.1 12.5 11.9 09/22/2006 16:40:00 1.1 0.5 2.3 0.4 0.8 0.5 1.9 0.4 1.5 0.4 2.6 0.4 232 17 203 165 12.4 0.1 12.5 11.9 09/22/2006 16:50:00 2.5 0.7 3.8 0.7 2.7 0.7 4.6 0.7 2.8 0.7 4.6 1.5 277 11 282 165 12.3 0 12.5 11.7 09/22/2006 17:00:00 3.3 0.5 4.2 1.9 3.3 0.5 4.6 1.5 3.1 0.6 4.6 1.5 286 10 276 165 11.9 0.1 12.2 11.9 09/22/2006 17:10:00 3.3 0.8 4.9 1.1 3.4 0.7 4.9 1.1 3.3 0.7 4.9 1.5 282 9 274 165 11.7 0 11.9 11.4 09/22/2006 17:20:00 2.1 0.6 3.4 0.4 2.1 0.5 3 0.7 2.3 0.4 3.4 1.1 253 26 286 165 11.4 0.2 11.7 10.9 09/22/2006 17:30:00 2.6 0.9 4.9 0.4 2.5 0.9 4.9 0.4 2.6 0.7 4.2 0.7 208 10 200 165 11.3 0 11.4 11.1 09/22/2006 17:40:00 3.8 0.5 4.9 2.3 3.8 0.6 4.9 2.3 3.8 0.6 5.3 2.3 218 10 212 165 11.2 0 11.4 10.9 09/22/2006 17:50:00 2.4 0.5 3.8 1.5 2.3 0.5 3.8 1.1 2.7 0.4 4.2 1.9 230 7 224 165 11.1 0 11.4 10.6 09/22/2006 18:00:00 2.2 0.4 3 1.1 2 0.4 3 1.1 2.2 0.4 3.4 1.1 266 26 226 165 11 0 11.4 10.6 09/22/2006 18:10:00 1.7 0.5 3 0.7 1.5 0.5 3 0.7 2 0.4 3 1.1 272 13 290 165 11.1 0 11.4 10.6 09/22/2006 18:20:00 1.5 0.4 2.6 0.4 1.3 0.4 2.3 0.4 1.9 0.3 2.6 1.1 266 9 276 165 11.3 0 11.7 11.1 09/22/2006 18:30:00 2 0.6 3 0.4 2 0.7 3 0.4 2.2 0.5 3 0.7 257 9 251 165 11.2 0 11.7 10.9 09/22/2006 18:40:00 3.3 0.6 4.9 1.9 3.2 0.6 4.9 1.9 3.4 0.7 5.3 2.3 217 18 195 165 10.9 0.1 11.4 10.9 09/22/2006 18:50:00 4.3 0.5 6.1 3.4 4.3 0.6 6.1 3 4.4 0.5 6.1 3.4 207 6 204 165 10.7 0 11.1 10.6 09/22/2006 19:00:00 5.1 0.6 6.8 3.8 5.2 0.6 6.8 3.8 5 0.5 6.1 3.8 216 5 210 165 10.7 0 10.9 10.3 09/22/2006 19:10:00 5.6 0.4 6.5 4.6 5.6 0.5 6.5 4.6 5.6 0.5 6.8 4.6 216 4 215 165 10.4 0 10.9 10.3 09/22/2006 19:20:00 4.9 0.6 6.5 3.4 4.8 0.7 6.5 3 4.7 0.6 6.1 3 212 5 217 165 10.3 0.1 10.6 9.8 09/22/2006 19:30:00 4.8 0.8 7.2 2.6 4.7 0.8 7.6 2.3 4.4 0.9 7.2 2.3 214 9 217 165 10.2 0 10.6 9.8 09/22/2006 19:40:00 5 0.8 6.5 2.3 5 1 6.5 1.9 4.8 1 6.8 1.9 221 8 222 165 10.2 0 10.6 9.8 09/22/2006 19:50:00 5.2 0.5 6.5 3.8 5.4 0.5 6.5 3.8 5.3 0.6 6.5 3.4 229 4 229 165 10.3 0 10.6 9.8 09/22/2006 20:00:00 4.2 0.8 5.7 2.3 4.1 0.9 5.7 1.9 4.1 0.7 5.3 2.6 238 7 230 165 10.4 0 10.9 9.8 09/22/2006 20:10:00 2.7 0.5 3.8 1.5 2.6 0.5 3.8 1.1 3 0.4 3.8 1.9 246 6 238 165 10.4 0 10.9 9.8 09/22/2006 20:20:00 2.5 0.5 3.4 1.1 2.4 0.4 3.4 1.5 2.9 0.3 3.4 2.3 249 9 239 165 10.1 0 10.6 9.6 09/22/2006 20:30:00 1.7 0.7 3.8 0.4 1.6 0.9 3.8 0.4 2.3 0.6 4.2 1.1 255 10 277 165 10.2 0 10.6 10.1 09/22/2006 20:40:00 1.2 0.4 2.3 0.4 0.8 0.4 1.9 0.4 1.5 0.4 2.3 0.7 261 11 276 165 10.5 0.1 10.9 10.3 09/22/2006 20:50:00 1.5 0.5 2.6 0.4 1.4 0.6 2.6 0.4 2 0.5 3 1.1 259 9 244 165 10.7 0 11.1 10.3 09/22/2006 21:00:00 2.7 1 4.6 0.4 2.6 1.2 4.9 0.4 2.8 0.9 4.9 1.1 274 16 284 165 10.7 0 10.9 10.6 09/22/2006 21:10:00 3 0.8 5.3 1.5 3.4 0.7 5.3 1.9 3.4 0.6 5.3 2.3 261 9 281 165 10.4 0 10.9 10.1 09/22/2006 21:20:00 2.6 0.4 4.2 1.5 2.4 0.5 3.8 1.1 2.8 0.3 3.8 1.9 217 22 243 165 10 0.1 10.6 9.6 09/22/2006 21:30:00 2.1 0.3 3 1.1 1.8 0.4 2.6 0.7 2.7 0.4 3.4 1.9 219 11 201 165 9.8 0.1 10.3 9.3 09/22/2006 21:40:00 3 0.5 4.2 1.9 2.9 0.5 4.2 1.9 3.5 0.4 4.2 2.6 241 8 248 165 9.6 0.1 10.1 9.3 09/22/2006 21:50:00 3.8 0.4 4.9 3 3.8 0.4 4.9 3 4 0.3 4.9 3 231 5 237 165 9.7 0.1 10.1 9.3 09/22/2006 22:00:00 4.3 0.5 5.3 2.6 4.2 0.5 5.3 2.6 4.1 0.5 5.3 2.6 231 6 229 165 9.7 0.1 9.8 9.3 09/22/2006 22:10:00 4.2 0.5 5.3 3 4.2 0.5 5.3 3 4.2 0.5 5.7 3 237 5 237 165 9.7 0.1 9.8 9.3 09/22/2006 22:20:00 4.1 0.4 5.3 3.4 4 0.5 4.9 3 4.2 0.5 5.3 3.4 231 5 231 165 9.8 0.2 10.3 9.3 09/22/2006 22:30:00 3.3 0.3 4.2 2.6 3.1 0.4 3.8 2.3 3.3 0.4 4.2 2.3 239 4 237 165 10 0.2 10.3 9.6 09/22/2006 22:40:00 2.6 0.3 3 1.9 2.3 0.3 3 1.5 2.6 0.3 3.4 1.9 233 5 247 165 10 0.2 10.6 9.3 09/22/2006 22:50:00 2.2 0.5 3.4 0.7 1.9 0.6 3.4 0.4 2.3 0.4 3.4 1.1 181 43 144 165 10 0.3 10.6 9.3 09/22/2006 23:00:00 2 0.6 3 0.4 1.5 0.7 3 0.4 2.2 0.5 3.4 1.1 199 15 200 165 9.6 0.1 9.8 9 09/22/2006 23:10:00 1 0.3 2.3 0.4 0.5 0.3 1.9 0.4 1.3 0.3 1.9 0.4 242 17 255 165 9.7 0 10.1 9.3 09/22/2006 23:20:00 1.6 0.5 2.6 0.4 1.2 0.5 2.3 0.4 1.9 0.3 2.6 1.1 264 9 276 165 10 0.2 10.3 9.6 09/22/2006 23:30:00 1.4 0.3 1.9 0.7 1.1 0.4 2.3 0.4 1.7 0.3 2.6 1.1 246 12 271 165 9.9 0.2 10.3 9.6 09/22/2006 23:40:00 2.1 0.5 3 1.1 1.9 0.6 3 0.7 2.2 0.5 3.4 1.5 273 12 282 165 10 0.1 10.3 9.6 09/22/2006 23:50:00 2.4 0.3 3 1.9 2.2 0.3 2.6 1.5 2.2 0.3 3 1.1 288 2 286 165 9.8 0 10.3 9.6 09/23/2006 00:00:00 2.4 0.3 3 1.5 2.2 0.3 2.6 1.5 2.4 0.3 3 1.9 279 4 276 165 9.7 0 9.8 9.6 09/23/2006 00:10:00 2.3 0.5 3.4 0.7 2.2 0.6 3.4 0.7 2.3 0.5 3.4 1.1 285 10 282 165 9.6 0.1 9.8 9.3 09/23/2006 00:20:00 2.7 0.3 3.4 1.5 2.6 0.3 3.4 1.5 2.4 0.4 3.4 1.5 281 5 284 165 9.4 0 9.6 8.8 09/23/2006 00:30:00 3.1 0.6 4.6 1.9 3.1 0.6 4.2 1.5 3 0.7 4.6 1.1 284 8 282 165 9.6 0.1 9.8 9 09/23/2006 00:40:00 3.5 0.4 4.6 2.3 3.7 0.3 4.6 3 3.7 0.3 4.6 3 273 3 272 165 9.8 0 9.8 9.6 09/23/2006 00:50:00 2.9 0.6 4.2 1.5 3.5 0.4 4.6 2.6 3.4 0.4 4.2 2.6 267 4 268 165 9.7 0 9.8 9.3 09/23/2006 01:00:00 3.6 0.6 4.9 2.3 4.3 0.4 5.3 3.4 4.1 0.4 5.3 3 270 4 275 165 9.6 0 9.8 9.3 09/23/2006 01:10:00 4.1 0.7 5.3 2.3 4.4 0.5 5.3 3 4.3 0.4 5.3 3 271 3 274 165 9.6 0 9.8 9.3 09/23/2006 01:20:00 4.5 0.8 6.1 2.6 4.9 0.6 6.1 3.4 4.8 0.6 6.1 3.4 273 5 281 165 9.6 0 9.8 9.3 09/23/2006 01:30:00 4 0.9 6.1 1.9 4.9 0.4 6.1 3.8 4.7 0.6 6.1 3.4 268 9 280 165 9.5 0.1 9.8 9 09/23/2006 01:40:00 3.4 0.5 4.6 2.3 4.6 0.3 5.3 4.2 4.4 0.3 5.3 3.8 260 5 252 165 9.2 0 9.6 8.8 09/23/2006 01:50:00 3.4 0.8 5.3 1.5 4.5 0.5 5.7 3.4 4.3 0.5 5.3 3 266 5 275 165 9.3 0 9.6 8.8 09/23/2006 02:00:00 2.6 0.5 4.2 1.5 3.7 0.3 4.2 3 3.5 0.2 4.2 3 262 4 271 165 9 0.1 9.6 8.8 09/23/2006 02:10:00 3 0.5 4.6 1.9 3.8 0.3 4.9 3 3.8 0.3 4.6 3 267 4 271 165 9 0.1 9.3 8.5 09/23/2006 02:20:00 3 0.6 4.2 1.1 3.7 0.4 4.6 2.6 3.6 0.4 4.2 2.6 267 4 267 165 9.1 0.1 9.6 8.8 09/23/2006 02:30:00 3.3 0.6 4.2 1.1 3.4 0.4 4.6 2.6 3.5 0.4 4.2 2.3 279 6 282 165 9.1 0.1 9.6 8.5 09/23/2006 02:40:00 2 0.8 3.4 0.4 2 0.8 3.4 0.7 2.4 0.6 3.4 1.5 259 13 273 165 9.4 0.2 9.8 8.8 09/23/2006 02:50:00 1.8 0.6 3 0.4 1.6 0.8 3 0.4 2.2 0.6 3.8 0.7 245 17 239 165 9.6 0.2 10.1 9 09/23/2006 03:00:00 1.7 0.6 3.4 0.4 1.4 0.6 3 0.4 2 0.5 3 0.7 243 14 237 165 9.5 0.2 9.8 8.8 09/23/2006 03:10:00 1.5 0.4 2.3 0.7 1.1 0.5 2.3 0.4 1.9 0.4 2.6 1.5 213 8 203 165 9 0.2 9.6 8.3 09/23/2006 03:20:00 1.8 0.2 2.3 1.1 1.3 0.2 1.9 0.4 2.1 0.2 2.6 1.5 197 3 198 165 8.9 0 9 8.5 09/23/2006 03:30:00 2 0.4 3 1.1 1.6 0.5 2.6 0.7 2.5 0.5 3.4 1.5 196 5 203 165 8.7 0.1 9 8.3 09/23/2006 03:40:00 3.6 0.4 4.6 2.6 3.5 0.4 4.6 2.3 4 0.4 4.9 3 207 2 209 165 8.9 0.1 9 8.3 09/23/2006 03:50:00 3.2 0.4 3.8 2.3 3.1 0.4 3.8 2.3 3.4 0.4 4.2 2.6 223 6 211 165 8.9 0 9 8.5 09/23/2006 04:00:00 3 0.4 3.8 2.3 2.8 0.4 3.8 1.9 3.2 0.4 4.2 2.3 220 4 227 165 9 0.2 9.3 8.5 09/23/2006 04:10:00 3.3 0.5 4.6 2.3 3.2 0.5 4.6 1.9 3 0.5 4.2 1.9 222 6 227 165 9.2 0 9.6 8.5 09/23/2006 04:20:00 2.8 0.4 3.4 1.1 2.5 0.5 3.4 0.7 2.6 0.5 3.4 1.1 230 11 203 165 9.2 0 9.3 8.8 09/23/2006 04:30:00 3 0.3 3.8 1.5 2.9 0.3 3.4 2.3 3.1 0.3 3.8 2.3 244 4 244 165 9.2 0.1 9.6 8.8 09/23/2006 04:40:00 2.7 0.3 3.4 1.9 2.5 0.3 3.4 1.9 3 0.2 3.4 2.6 228 5 232 165 9 0 9.3 8.8 09/23/2006 04:50:00 2.3 0.3 3 1.5 2.1 0.4 2.6 1.1 2.4 0.5 3.4 1.5 216 2 216 165 9.1 0 9.3 9 09/23/2006 05:00:00 1.9 0.4 3.4 1.1 1.5 0.5 3 0.4 2.2 0.3 3 1.5 221 6 235 165 9.2 0 9.3 9 09/23/2006 05:10:00 1.8 0.4 3 1.1 1.5 0.5 3 0.4 2.1 0.2 2.6 1.5 222 11 255 165 9.2 0 9.6 9 09/23/2006 05:20:00 1.5 0.4 2.6 0.4 1.2 0.5 2.3 0.4 1.8 0.3 2.6 1.1 241 18 230 165 9.2 0 9.6 9 09/23/2006 05:30:00 1.6 0.5 3 0.4 1.5 0.5 3 0.4 1.6 0.4 2.6 0.7 279 16 282 165 9.2 0 9.3 9 09/23/2006 05:40:00 1 0.5 2.6 0.4 0.6 0.5 2.3 0.4 1.2 0.4 1.9 0.4 248 26 317 165 9.2 0 9.6 9 09/23/2006 05:50:00 1.4 0.4 2.6 0.4 1.2 0.6 3 0.4 1.8 0.5 3.4 1.1 258 10 273 165 9.3 0.1 9.6 8.8 09/23/2006 06:00:00 1.5 0.6 2.6 0.4 1.2 0.7 2.6 0.4 1.6 0.6 3 0.4 282 12 271 165 9.3 0 9.6 9 09/23/2006 06:10:00 2.3 0.5 3.4 1.5 2.2 0.6 3 1.1 1.8 0.5 2.6 0.7 297 2 298 165 9.1 0.1 9.3 8.8 09/23/2006 06:20:00 1.7 0.5 2.6 0.7 1.3 0.7 2.6 0.4 1.5 0.4 2.6 0.7 298 3 303 165 9 0 9.3 8.8 09/23/2006 06:30:00 1 0.3 1.9 0.4 0.6 0.3 1.5 0.4 1.2 0.3 1.9 0.7 297 0 297 165 9 0 9.3 8.8 09/23/2006 06:40:00 1.2 0.3 1.9 0.7 0.7 0.3 1.5 0.4 1.4 0.2 1.9 0.7 309 7 311 165 9 0.1 9.3 8.5 09/23/2006 06:50:00 1 0.4 1.9 0.4 0.5 0.3 1.5 0.4 1.2 0.4 1.9 0.4 311 0 311 165 9 0 9.3 8.8 09/23/2006 07:00:00 0.4 0 0.7 0.4 0.4 0 0.4 0.4 0.4 0.1 1.1 0.4 311 0 311 165 9.2 0 9.3 8.8 09/23/2006 07:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 311 0 165 165 9.4 0.2 9.8 8.8 09/23/2006 07:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0.2 1.1 0.4 236 72 165 165 10 0 10.3 9.6 09/23/2006 07:30:00 1 0.6 1.9 0.4 0.6 0.4 1.5 0.4 1.2 0.5 1.9 0.4 169 5 173 165 9.9 0 10.1 9.6 09/23/2006 07:40:00 0.7 0.4 1.9 0.4 0.4 0.2 1.1 0.4 0.9 0.5 1.9 0.4 199 12 177 165 9.7 0.1 10.3 9 09/23/2006 07:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 207 0 165 165 10.6 0.3 11.4 9.8 09/23/2006 08:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 207 0 165 165 11.8 0.2 12.2 10.9 09/23/2006 08:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.7 0.4 207 1 165 165 11.7 0.1 12.2 11.1 09/23/2006 08:20:00 0.4 0.2 1.1 0.4 0.4 0 0.7 0.4 0.6 0.3 1.5 0.4 205 5 205 165 12 0.1 12.5 11.4 09/23/2006 08:30:00 0.9 0.4 2.3 0.4 0.6 0.4 1.9 0.4 1.1 0.4 2.3 0.4 213 17 205 165 12.2 0 12.5 11.9 09/23/2006 08:40:00 1 0.4 1.9 0.4 0.8 0.4 1.9 0.4 1.4 0.4 2.3 0.4 235 7 226 165 12.1 0 12.2 11.9 09/23/2006 08:50:00 0.7 0.4 1.9 0.4 0.6 0.3 1.5 0.4 1.1 0.4 1.9 0.4 227 29 242 165 12.4 0.2 13.3 11.9 09/23/2006 09:00:00 0.8 0.4 1.9 0.4 0.8 0.4 1.9 0.4 0.9 0.3 1.9 0.4 292 1 291 165 13.3 0.3 14.4 12.7 09/23/2006 09:10:00 0.4 0.1 0.7 0.4 0.4 0.1 1.1 0.4 0.5 0.3 1.5 0.4 239 41 251 165 13.1 0.1 14.1 13 09/23/2006 09:20:00 0.6 0.3 1.5 0.4 0.7 0.4 1.9 0.4 0.8 0.4 1.9 0.4 274 23 243 165 13.2 0 13.5 13 09/23/2006 09:30:00 0.4 0.2 1.5 0.4 0.5 0.3 1.5 0.4 0.6 0.3 1.5 0.4 294 13 284 165 13.6 0 13.8 13.3 09/23/2006 09:40:00 0.9 0.4 2.3 0.4 1.2 0.5 2.3 0.4 1.3 0.6 2.6 0.4 262 28 229 165 13.3 0.2 13.8 13 09/23/2006 09:50:00 1.3 0.5 3 0.4 1.8 0.6 2.6 0.4 1.7 0.5 2.6 0.4 266 10 278 165 13.3 0 13.5 13 09/23/2006 10:00:00 1.3 0.4 2.6 0.4 1.7 0.5 2.6 0.4 1.8 0.4 2.6 1.1 259 17 250 165 13.1 0.1 13.5 13 09/23/2006 10:10:00 1.2 0.4 3 0.4 1.7 0.5 3 0.4 1.8 0.5 3.4 0.7 263 6 253 165 13.3 0 13.5 13 09/23/2006 10:20:00 0.8 0.4 1.9 0.4 1 0.5 2.3 0.4 1.5 0.4 2.6 0.4 266 3 276 165 13.6 0.2 14.1 13.3 09/23/2006 10:30:00 1.3 1 3.8 0.4 1.3 1 3.8 0.4 1.8 1 4.2 0.4 198 61 127 165 14 0.1 14.4 13.5 09/23/2006 10:40:00 1.7 1 4.2 0.4 1.7 1 4.2 0.4 2.3 0.7 4.2 0.4 142 28 123 165 13.9 0 14.4 13.3 09/23/2006 10:50:00 2.8 0.7 4.2 0.7 2.8 0.7 4.6 0.7 3.1 0.6 4.6 1.5 146 15 121 165 13.8 0.2 14.4 13 09/23/2006 11:00:00 2.8 0.8 4.9 0.7 2.7 0.9 4.9 0.4 3.2 0.8 5.3 0.7 140 20 160 165 13.5 0.2 13.8 12.7 09/23/2006 11:10:00 3.9 0.7 5.7 1.9 3.9 0.6 5.7 1.9 4 0.6 5.3 2.3 140 12 122 165 14.1 0.2 14.6 13.5 09/23/2006 11:20:00 3.4 0.9 5.7 1.1 3.3 0.9 5.7 1.5 3.6 0.8 5.7 2.3 138 12 133 165 13.1 0.8 14.6 11.9 09/23/2006 11:30:00 2.6 0.6 3.8 1.1 2.4 0.6 3.8 0.7 2.8 0.6 4.2 1.5 145 12 131 165 11.9 0.1 12.5 11.7 09/23/2006 11:40:00 1.7 0.7 3.8 0.4 1.5 0.8 3.8 0.4 2.1 0.7 4.2 0.7 137 17 145 165 12.1 0.2 12.7 11.7 09/23/2006 11:50:00 1.4 0.8 3.4 0.4 1.2 0.8 3.8 0.4 1.9 0.8 3.8 0.4 135 18 133 165 12.9 0.1 13.3 12.5 09/23/2006 12:00:00 2.1 0.8 4.6 0.4 2 0.9 4.6 0.4 2.5 0.7 4.9 1.1 130 18 151 165 13 0 13.3 12.7 09/23/2006 12:10:00 2.7 0.7 4.9 0.4 2.7 0.7 4.6 0.4 2.9 0.8 4.6 0.7 134 15 129 165 12.6 0.3 13.5 12.2 09/23/2006 12:20:00 1.8 0.8 4.2 0.4 1.6 0.8 4.2 0.4 2.2 0.7 3.8 0.4 130 19 106 165 12.4 0.3 13 11.9 09/23/2006 12:30:00 1.6 0.7 3.4 0.4 1.4 0.8 3 0.4 2 0.7 3.8 0.4 135 20 159 165 13 0.4 13.5 12.2 09/23/2006 12:40:00 2 0.8 4.6 0.4 1.8 1 4.6 0.4 2.3 0.8 3.8 0.4 137 17 115 165 13.7 0.2 14.4 13 09/23/2006 12:50:00 2.1 0.6 3.8 0.7 2.1 0.6 3.8 0.7 2.6 0.5 3.8 0.4 107 20 136 165 13.1 0.4 14.1 12.7 09/23/2006 13:00:00 2.1 1 4.6 0.4 1.9 1.1 4.6 0.4 2.2 1 4.6 0.4 120 20 102 165 13.4 0.3 14.1 12.7 09/23/2006 13:10:00 2.9 0.8 5.3 1.1 2.9 0.8 5.3 0.7 3.2 0.7 4.6 1.1 114 17 117 165 13.5 0.3 14.1 12.7 09/23/2006 13:20:00 3.1 0.8 5.3 1.5 2.9 0.9 5.3 1.1 3.5 0.7 5.7 1.5 140 15 130 165 12.7 0.1 13.3 12.5 09/23/2006 13:30:00 3.7 0.6 5.3 1.9 3.6 0.6 5.3 1.5 3.9 0.6 5.3 1.9 133 9 134 165 13.1 0.1 13.5 12.7 09/23/2006 13:40:00 3.7 0.8 6.1 1.5 3.7 0.8 5.7 1.9 3.7 0.8 6.1 1.5 113 14 110 165 14.3 0.3 14.9 13.5 09/23/2006 13:50:00 4.1 0.7 6.5 1.9 4 0.7 6.5 1.5 4 0.8 6.5 1.5 108 13 99 165 14.4 0 14.9 13.8 09/23/2006 14:00:00 4.4 0.7 6.5 2.6 4.4 0.7 6.5 2.6 4.4 0.9 6.1 1.1 108 12 106 165 14.3 0.1 14.6 13.8 09/23/2006 14:10:00 4.7 0.6 6.1 3 4.7 0.6 6.1 2.6 4.9 0.6 6.5 2.6 117 7 110 165 13.3 0.3 14.1 12.7 09/23/2006 14:20:00 4.8 0.5 6.1 3.8 4.7 0.5 6.1 3.4 4.9 0.5 6.1 3.4 121 8 105 165 12.9 0 13.5 12.7 09/23/2006 14:30:00 4.2 0.5 5.3 2.6 4.1 0.5 5.3 2.6 4.3 0.5 5.7 2.6 120 8 117 165 13 0.1 13.5 12.7 09/23/2006 14:40:00 4.3 0.6 6.1 2.6 4.3 0.6 6.1 2.6 4.4 0.6 5.7 3 120 9 119 165 13 0.2 13.5 12.7 09/23/2006 14:50:00 4.1 0.6 5.3 1.9 4 0.6 5.7 1.5 4.2 0.5 5.3 2.3 120 8 126 165 13.1 0 13.3 13 09/23/2006 15:00:00 4.1 0.5 5.3 2.6 4.1 0.5 5.3 2.3 4.3 0.5 5.3 3 125 8 112 165 12.5 0.4 13.3 11.7 09/23/2006 15:10:00 3.9 0.5 4.9 3 3.9 0.5 5.3 2.6 4.1 0.5 5.7 2.6 125 6 123 165 11.7 0 11.9 11.7 09/23/2006 15:20:00 2.9 0.6 4.6 1.1 2.7 0.7 4.6 0.4 3.2 0.5 4.9 2.3 154 14 123 165 11.5 0.3 12.2 10.9 09/23/2006 15:30:00 1.8 0.5 3 0.4 1.5 0.6 2.6 0.4 2.1 0.4 3 1.1 139 13 145 165 10.7 0.1 11.1 10.6 09/23/2006 15:40:00 1.9 0.4 2.6 1.1 1.8 0.4 2.6 0.7 2.2 0.4 3 1.1 120 11 124 165 10.5 0 10.9 10.6 09/23/2006 15:50:00 1.6 0.3 2.6 0.7 1.3 0.4 2.6 0.4 2.1 0.3 3 1.1 154 10 145 165 10.3 0.1 10.9 10.3 09/23/2006 16:00:00 1.8 0.6 3.8 0.4 1.5 0.7 3.8 0.4 2.2 0.6 3.8 1.1 147 13 159 165 10.4 0 10.9 9.8 09/23/2006 16:10:00 1.3 0.5 3 0.4 0.8 0.5 2.6 0.4 1.6 0.5 3 0.4 148 15 144 165 11.2 0.4 11.9 10.6 09/23/2006 16:20:00 0.7 0.4 1.9 0.4 0.4 0.2 1.1 0.4 0.9 0.4 1.9 0.4 124 18 117 165 11.4 0 11.7 11.1 09/23/2006 16:30:00 1 0.5 2.3 0.4 0.7 0.4 1.9 0.4 1.1 0.5 2.3 0.4 121 17 130 165 10.7 0.1 11.4 10.3 09/23/2006 16:40:00 0.8 0.2 1.5 0.4 0.4 0.1 0.7 0.4 1.2 0.5 2.3 0.4 147 11 164 165 10 0.2 10.6 9.6 09/23/2006 16:50:00 1.5 0.5 2.3 0.7 1.1 0.6 2.3 0.4 1.7 0.5 2.6 0.4 120 3 118 165 9.7 0.1 10.3 9.6 09/23/2006 17:00:00 1 0.4 1.9 0.4 0.6 0.4 1.9 0.4 1.4 0.3 1.9 0.4 106 7 115 165 9.7 0.1 10.3 9.6 09/23/2006 17:10:00 0.6 0.4 1.9 0.4 0.5 0.2 1.1 0.4 1.1 0.5 2.3 0.4 123 1 119 165 9.7 0.1 10.3 9.3 09/23/2006 17:20:00 0.9 0.3 1.5 0.4 0.5 0.2 1.1 0.4 1.4 0.2 1.9 0.7 110 4 118 165 9.3 0 9.6 9 09/23/2006 17:30:00 0.4 0.2 1.1 0.4 0.4 0 0.4 0.4 1 0.4 1.5 0.4 84 32 102 165 9.2 0 9.3 9 09/23/2006 17:40:00 0.6 0.3 1.1 0.4 0.4 0 0.4 0.4 1.1 0.2 1.5 0.7 1 0 1 165 9.1 0 9.3 9 09/23/2006 17:50:00 1.5 0.6 2.6 0.4 0.7 0.5 1.9 0.4 1.8 0.5 2.6 0.7 4 6 4 165 8.9 0 9 8.8 09/23/2006 18:00:00 2 0.3 2.6 1.1 1.6 0.4 2.3 0.7 2.1 0.3 3 1.1 35 9 21 165 8.8 0 9 8.5 09/23/2006 18:10:00 1.4 0.3 2.3 0.7 1 0.3 1.9 0.4 1.8 0.2 2.3 1.1 69 7 57 165 9.1 0 9.3 8.8 09/23/2006 18:20:00 1.2 0.3 2.3 0.4 0.6 0.3 1.9 0.4 1.6 0.3 2.3 0.7 66 13 73 165 9.4 0 9.6 9 09/23/2006 18:30:00 1.1 0.3 1.9 0.4 0.4 0.2 1.5 0.4 1.5 0.3 2.3 0.7 48 13 31 165 9.2 0.1 9.6 9 09/23/2006 18:40:00 0.6 0.3 1.5 0.4 0.4 0.1 1.1 0.4 0.9 0.5 1.9 0.4 48 22 61 165 8.7 0 9 8.5 09/23/2006 18:50:00 1 0.4 1.9 0.4 0.4 0.1 1.1 0.4 1.5 0.3 2.3 0.4 49 23 24 165 8.9 0 9 8.5 09/23/2006 19:00:00 1.2 0.2 1.5 0.7 0.5 0.2 1.1 0.4 1.5 0.3 2.3 1.1 36 15 23 165 8.6 0 9 8.5 09/23/2006 19:10:00 1.3 0.3 1.9 0.7 0.6 0.3 1.1 0.4 1.6 0.3 2.3 0.7 41 22 78 165 8.9 0 9 8.8 09/23/2006 19:20:00 1.3 0.2 1.9 0.7 0.6 0.3 1.1 0.4 1.7 0.2 2.3 1.1 29 6 25 165 8.7 0 9 8.5 09/23/2006 19:30:00 1.1 0.3 1.9 0.4 0.5 0.3 1.5 0.4 1.3 0.3 1.9 0.7 60 15 67 165 8.9 0 9 8.5 09/23/2006 19:40:00 1 0.2 1.1 0.7 0.4 0.1 0.7 0.4 1.4 0.2 1.9 1.1 30 4 36 165 8.9 0 9 8.8 09/23/2006 19:50:00 1 0.2 1.5 0.7 0.4 0 0.4 0.4 1.3 0.2 1.5 0.7 15 4 12 165 8.7 0 9 8.5 09/23/2006 20:00:00 0.4 0.1 1.1 0.4 0.4 0 0.4 0.4 0.6 0.3 1.1 0.4 28 6 13 165 8.6 0 8.8 8.3 09/23/2006 20:10:00 0.8 0.3 1.5 0.4 0.4 0 0.4 0.4 1.1 0.2 1.5 0.7 16 10 6 165 8.6 0 8.8 8.3 09/23/2006 20:20:00 0.7 0.3 1.5 0.4 0.4 0 0.4 0.4 0.9 0.4 1.5 0.4 4 2 6 165 8.5 0 8.8 8.3 09/23/2006 20:30:00 0.4 0.1 1.1 0.4 0.4 0 0.4 0.4 0.5 0.2 1.1 0.4 5 1 6 165 8.2 0.1 8.5 8 09/23/2006 20:40:00 0.4 0.2 1.1 0.4 0.4 0 0.4 0.4 0.8 0.2 1.1 0.4 4 2 6 165 8.1 0.1 8.5 7.8 09/23/2006 20:50:00 0.9 0.4 1.5 0.4 0.4 0.1 1.1 0.4 1.2 0.3 1.5 0.4 337 20 340 165 8.6 0.2 9 8 09/23/2006 21:00:00 1 0.4 1.9 0.4 0.4 0.2 1.1 0.4 1.3 0.3 1.9 0.7 318 6 330 165 8.9 0 9 8.5 09/23/2006 21:10:00 1.4 0.2 1.9 0.7 0.4 0.1 0.7 0.4 1.6 0.2 1.9 1.1 350 1 344 165 8.6 0.1 9.3 8.3 09/23/2006 21:20:00 1.5 0.3 2.3 0.7 0.5 0.3 1.9 0.4 1.7 0.3 2.3 1.1 351 2 351 165 8.5 0.1 8.8 8 09/23/2006 21:30:00 1.9 0.3 2.6 1.1 1.3 0.4 2.3 0.4 1.9 0.3 2.3 1.1 345 5 345 165 8.2 0.1 8.5 7.5 09/23/2006 21:40:00 2.1 0.3 2.6 1.1 1.6 0.5 2.6 0.4 2 0.4 2.6 1.1 343 4 338 165 8.1 0 8.3 7.5 09/23/2006 21:50:00 1.7 0.2 2.3 1.1 0.5 0.2 1.1 0.4 1.7 0.3 2.3 1.1 357 4 350 165 8.1 0 8.3 8 09/23/2006 22:00:00 2 0.2 2.3 1.5 0.5 0.2 1.5 0.4 2 0.2 2.3 1.5 3 2 1 165 8.2 0 8.5 8 09/23/2006 22:10:00 1.7 0.2 2.3 1.5 0.4 0.1 1.1 0.4 1.7 0.2 2.3 1.1 1 2 360 165 8.2 0 8.5 8 09/23/2006 22:20:00 1.4 0.2 1.9 1.1 0.4 0.2 1.1 0.4 1.5 0.2 1.9 1.1 8 7 4 165 8.2 0 8.5 7.8 09/23/2006 22:30:00 1.3 0.3 1.9 0.7 0.6 0.3 1.5 0.4 1.5 0.3 1.9 0.7 19 0 19 165 8.2 0 8.5 7.8 09/23/2006 22:40:00 1.7 0.4 2.3 0.7 0.9 0.4 1.5 0.4 1.8 0.4 2.6 0.7 18 4 19 165 7.8 0.1 8.3 7.3 09/23/2006 22:50:00 2.1 0.4 2.6 1.1 1.2 0.6 2.6 0.4 2.5 0.4 3 1.5 9 9 353 165 7.7 0 8 7.3 09/23/2006 23:00:00 2.3 0.2 2.6 1.9 0.9 0.4 1.9 0.4 2.7 0.2 3.4 2.3 7 8 18 165 7.5 0.1 7.8 7 09/23/2006 23:10:00 2.1 0.2 2.6 1.5 1.1 0.5 2.3 0.4 2.2 0.2 2.6 1.9 352 2 356 165 7.6 0 7.8 7.3 09/23/2006 23:20:00 2.4 0.2 3 1.9 1.7 0.6 2.6 0.4 2.5 0.3 3 1.9 351 6 345 165 7.4 0.2 7.8 7 09/23/2006 23:30:00 2.6 0.2 3 1.9 1.7 0.5 3 0.4 3 0.3 3.8 2.3 356 6 357 165 6.4 0.2 7 6 09/23/2006 23:40:00 2.4 0.2 3 1.9 1.5 0.5 2.6 0.4 2.7 0.2 3.4 2.3 356 5 2 165 6.3 0.1 6.7 6 09/23/2006 23:50:00 2.3 0.2 3 1.9 1.8 0.4 2.6 0.7 2.7 0.3 3.4 2.3 349 5 357 165 6.1 0.2 6.7 5.7 09/24/2006 00:00:00 2.1 0.2 2.6 1.5 1.1 0.5 2.3 0.4 2.5 0.3 3.4 1.9 358 9 5 165 6.2 0.2 6.5 5.7 09/24/2006 00:10:00 2 0.2 2.6 1.5 1 0.4 2.3 0.4 2.3 0.3 3 1.5 11 6 12 165 6.4 0.1 6.7 5.7 09/24/2006 00:20:00 1.8 0.8 2.6 0.4 1.4 0.7 2.6 0.4 2.2 0.7 3.4 0.7 61 38 12 165 6.6 0.1 7 6.2 09/24/2006 00:30:00 0.5 0.3 1.5 0.4 0.4 0.1 1.1 0.4 1 0.4 1.9 0.4 80 18 77 165 6.7 0.1 7 6.2 09/24/2006 00:40:00 1.6 0.4 3 0.7 1.2 0.6 3 0.4 1.7 0.4 2.6 0.4 92 16 92 165 7 0.1 7.5 6.5 09/24/2006 00:50:00 1.1 0.6 2.6 0.4 0.8 0.6 2.3 0.4 1.6 0.5 2.6 0.4 104 7 99 165 7.3 0.2 7.5 6.7 09/24/2006 01:00:00 1.1 0.6 2.3 0.4 0.8 0.5 1.9 0.4 1.3 0.7 2.3 0.4 99 4 96 165 7.3 0.1 7.5 7 09/24/2006 01:10:00 1.4 0.4 2.3 0.4 0.9 0.5 2.3 0.4 1.7 0.3 2.3 1.1 86 9 91 165 7.3 0.1 7.5 7 09/24/2006 01:20:00 1.4 0.4 2.3 0.4 1 0.5 2.3 0.4 1.8 0.3 2.6 1.1 78 6 75 165 7.1 0.2 7.5 6.5 09/24/2006 01:30:00 2 0.3 2.6 1.5 1.8 0.3 2.6 1.1 2.3 0.3 3 1.5 85 8 81 165 7 0.1 7.3 6.5 09/24/2006 01:40:00 1.7 0.3 2.6 0.7 1.3 0.4 2.3 0.4 2.1 0.3 2.6 1.5 64 4 65 165 7.3 0.1 7.5 6.7 09/24/2006 01:50:00 1.2 0.3 1.9 0.4 0.6 0.3 1.5 0.4 1.6 0.3 2.3 0.4 73 7 61 165 7.3 0 7.5 6.7 09/24/2006 02:00:00 0.8 0.4 1.9 0.4 0.4 0.2 1.5 0.4 1.3 0.4 3 0.4 82 5 81 165 7.1 0 7.5 6.7 09/24/2006 02:10:00 0.6 0.4 1.5 0.4 0.4 0 0.4 0.4 0.9 0.5 1.9 0.4 82 9 71 165 7.4 0.1 7.8 7 09/24/2006 02:20:00 0.8 0.3 1.1 0.4 0.4 0 0.7 0.4 1.3 0.3 1.9 0.4 17 17 26 165 7.1 0.2 7.5 6.7 09/24/2006 02:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.8 0.2 1.1 0.4 4 0 165 165 6.7 0.1 7 6.2 09/24/2006 02:40:00 0.5 0.2 1.1 0.4 0.4 0 0.4 0.4 0.7 0.4 1.5 0.4 358 10 346 165 6.6 0.1 7.3 6.2 09/24/2006 02:50:00 0.6 0.3 1.1 0.4 0.4 0 0.4 0.4 0.9 0.4 1.5 0.4 332 0 332 165 6.8 0.1 7 6.2 09/24/2006 03:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 332 0 165 165 6.5 0.2 7 6 09/24/2006 03:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 332 0 165 165 6.7 0.2 7.3 6 09/24/2006 03:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 332 0 165 165 7 0.2 7.5 6.2 09/24/2006 03:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 332 0 165 165 6.9 0.2 7.5 6.2 09/24/2006 03:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 332 0 165 165 6.9 0.2 7.3 6.2 09/24/2006 03:50:00 0.4 0 0.7 0.4 0.4 0 0.4 0.4 0.5 0.3 1.5 0.4 240 90 138 165 7.1 0 7.3 6.7 09/24/2006 04:00:00 0.5 0.2 1.1 0.4 0.4 0 0.4 0.4 0.6 0.4 1.5 0.4 139 0 139 165 6.9 0 7.3 6.7 09/24/2006 04:10:00 0.4 0.1 0.7 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 139 0 139 165 6.8 0 7 6.7 09/24/2006 04:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0.1 1.1 0.4 131 24 165 165 6.6 0.2 7 6 09/24/2006 04:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.9 0.3 1.5 0.4 43 7 165 165 6.4 0.1 6.7 6 09/24/2006 04:40:00 0.8 0.3 1.5 0.4 0.4 0 0.7 0.4 1.4 0.2 1.9 1.1 2 0 2 165 6.4 0 6.7 6 09/24/2006 04:50:00 1 0.5 2.3 0.4 0.5 0.2 1.5 0.4 1.7 0.4 2.6 1.1 355 5 352 165 6.4 0.1 6.7 6 09/24/2006 05:00:00 0.7 0.2 1.1 0.4 0.4 0 0.4 0.4 1.2 0.2 1.9 0.7 356 8 354 165 6.6 0.1 6.7 6 09/24/2006 05:10:00 0.5 0.3 1.1 0.4 0.4 0 0.4 0.4 0.8 0.4 1.5 0.4 47 15 30 165 6.8 0.2 7.3 5.7 09/24/2006 05:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 63 0 165 165 7.2 0.2 7.5 6.7 09/24/2006 05:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 63 0 165 165 7 0.1 7.5 6.5 09/24/2006 05:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 63 0 165 165 6.9 0.1 7.3 6.5 09/24/2006 05:50:00 0.4 0.2 1.9 0.4 0.4 0 1.1 0.4 0.4 0.3 1.9 0.4 60 11 16 165 7.2 0.2 7.5 6.7 09/24/2006 06:00:00 1.1 0.3 1.9 0.4 0.4 0.1 1.5 0.4 1.5 0.4 2.6 0.7 10 1 10 165 7.1 0.1 7.5 6.5 09/24/2006 06:10:00 1.9 0.3 2.3 1.1 0.6 0.2 1.1 0.4 2.2 0.2 2.6 1.5 4 4 10 165 6.9 0.2 7.3 6.2 09/24/2006 06:20:00 2.3 0.3 3 1.5 0.7 0.3 1.5 0.4 2.5 0.3 3 1.9 4 1 360 165 6.9 0.1 7.3 6.2 09/24/2006 06:30:00 2.5 0.2 3 2.3 1 0.5 2.3 0.4 2.6 0.2 3 2.3 355 2 360 165 6.8 0.1 7.3 6.2 09/24/2006 06:40:00 2.2 0.4 3 1.5 1.8 0.5 3 0.7 2.2 0.4 3 1.5 342 3 340 165 6.9 0.1 7.3 6.2 09/24/2006 06:50:00 1.8 0.3 2.3 1.1 0.9 0.4 1.9 0.4 1.8 0.2 2.3 1.1 347 6 340 165 7.1 0 7.3 6.7 09/24/2006 07:00:00 0.9 0.4 1.5 0.4 0.4 0.2 1.1 0.4 0.9 0.4 1.5 0.4 296 22 327 165 7.2 0.2 7.5 6.7 09/24/2006 07:10:00 0.9 0.3 1.5 0.4 0.4 0 0.4 0.4 1.3 0.2 1.9 1.1 274 4 276 165 7.4 0.1 7.8 7 09/24/2006 07:20:00 0.9 0.4 1.9 0.4 0.5 0.3 1.1 0.4 1.2 0.3 1.9 0.4 276 11 286 165 7.7 0 8 7.3 09/24/2006 07:30:00 1.2 0.2 1.9 0.7 0.5 0.3 1.5 0.4 1.4 0.4 2.3 0.7 293 3 287 165 7.5 0.1 7.8 7 09/24/2006 07:40:00 0.7 0.3 1.5 0.4 0.4 0 0.4 0.4 0.9 0.2 1.5 0.4 305 7 295 165 7.6 0 7.8 7.3 09/24/2006 07:50:00 1 0.4 1.9 0.4 0.6 0.4 1.5 0.4 1.1 0.3 1.9 0.4 306 4 301 165 7.8 0 8 7.5 09/24/2006 08:00:00 0.8 0.4 1.9 0.4 0.4 0.2 1.5 0.4 1 0.3 1.9 0.4 302 5 300 165 7.9 0 8 7.5 09/24/2006 08:10:00 0.5 0.2 1.1 0.4 0.4 0 0.4 0.4 0.8 0.3 1.5 0.4 304 3 310 165 8.2 0.2 8.8 7.8 09/24/2006 08:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0.1 0.7 0.4 301 0 165 165 9.2 0.3 9.8 8.5 09/24/2006 08:30:00 0.5 0.2 1.1 0.4 0.4 0 0.7 0.4 0.5 0.3 1.5 0.4 16 13 14 165 10.3 0.2 10.9 9.6 09/24/2006 08:40:00 0.5 0.2 1.5 0.4 0.4 0 0.7 0.4 0.5 0.2 1.5 0.4 30 6 26 165 11 0.3 11.4 10.3 09/24/2006 08:50:00 0.4 0.1 1.1 0.4 0.4 0 0.4 0.4 0.4 0.2 1.1 0.4 27 1 27 165 11.5 0 11.9 11.1 09/24/2006 09:00:00 0.4 0.3 1.9 0.4 0.4 0.1 0.7 0.4 0.4 0.2 1.1 0.4 23 7 4 165 11.6 0.1 12.2 11.4 09/24/2006 09:10:00 0.4 0.1 1.1 0.4 0.4 0 0.4 0.4 0.4 0.1 0.7 0.4 10 1 9 165 11.5 0.1 12.2 11.1 09/24/2006 09:20:00 0.4 0.1 1.1 0.4 0.4 0 0.7 0.4 0.5 0.2 1.5 0.4 32 53 14 165 12.4 0.2 13 11.9 09/24/2006 09:30:00 1.6 0.6 3.8 0.4 1.3 0.7 3.4 0.4 1.9 0.5 3.4 0.4 141 27 165 165 12.1 0.1 12.5 11.7 09/24/2006 09:40:00 1.5 0.6 3 0.4 1.5 0.6 3 0.4 2.1 0.5 3.4 0.7 139 13 163 165 11.8 0.3 12.5 11.4 09/24/2006 09:50:00 1.9 0.7 3.8 0.4 1.9 0.8 3.8 0.4 2.3 0.6 3.8 1.1 144 18 160 165 11.5 0 11.9 11.4 09/24/2006 10:00:00 1.6 0.7 3.4 0.4 1.5 0.7 3 0.4 2.1 0.5 3.8 0.7 154 15 164 165 11.9 0.1 12.2 11.7 09/24/2006 10:10:00 1.2 0.8 3.4 0.4 1.1 0.8 2.6 0.4 1.5 0.8 3.8 0.4 169 53 203 165 11.9 0.3 12.7 11.4 09/24/2006 10:20:00 1 0.6 4.2 0.4 0.9 0.6 3.8 0.4 1.4 0.6 3.4 0.4 233 36 210 165 11.6 0.6 12.7 10.9 09/24/2006 10:30:00 0.4 0.2 1.1 0.4 0.4 0.1 1.1 0.4 0.8 0.4 1.9 0.4 263 66 234 165 11.7 0.5 12.7 11.1 09/24/2006 10:40:00 1 0.5 2.3 0.4 0.8 0.5 1.9 0.4 1.3 0.5 2.3 0.4 318 39 214 165 13.1 0.2 13.5 12.7 09/24/2006 10:50:00 1.4 0.6 3 0.4 1.2 0.6 3 0.4 1.5 0.5 2.6 0.4 293 19 287 165 11.9 0.6 13 11.1 09/24/2006 11:00:00 1.9 1.1 3.8 0.4 1.8 1.1 4.2 0.4 1.7 0.7 3 0.4 287 16 295 165 12 0.5 12.7 11.1 09/24/2006 11:10:00 2.3 1 4.6 0.4 2.3 1.1 4.9 0.4 2.4 0.9 4.6 0.7 275 20 281 165 12.6 0.3 13 11.9 09/24/2006 11:20:00 2.5 0.9 4.2 0.4 2.7 1.1 4.9 0.4 2.8 1 4.9 0.4 265 56 282 165 12.8 0.2 13.3 12.5 09/24/2006 11:30:00 0.7 0.5 2.3 0.4 0.6 0.5 2.6 0.4 1.3 0.6 2.6 0.4 123 29 154 165 11.2 0.5 12.5 10.6 09/24/2006 11:40:00 0.9 0.7 2.3 0.4 0.6 0.4 1.9 0.4 1 0.6 2.6 0.4 48 51 12 165 10.5 0 10.9 10.3 09/24/2006 11:50:00 3.3 1.4 6.8 1.1 2.7 1.7 6.8 0.4 3.2 1.1 6.1 1.5 355 14 347 165 11.3 0.3 11.7 10.9 09/24/2006 12:00:00 4.7 0.8 6.5 2.3 4.4 1 6.5 1.9 4.1 0.8 5.7 1.9 347 8 345 165 11.7 0 11.9 11.4 09/24/2006 12:10:00 3.6 1 6.5 1.1 2.9 1 6.8 0.4 2.9 1.1 5.3 0.7 358 13 31 165 11.4 0.1 11.9 11.1 09/24/2006 12:20:00 3.8 1.1 6.5 1.5 3.2 1.2 6.5 1.1 2.8 1.1 5.7 0.4 349 13 323 165 11.3 0 11.7 11.1 09/24/2006 12:30:00 3.5 1.2 6.5 0.7 3.3 1.4 6.5 0.4 2.7 1.2 5.3 0.4 304 20 282 165 11.6 0.6 13 11.1 09/24/2006 12:40:00 3.7 0.8 5.3 1.1 3.7 0.9 5.3 0.7 3 0.8 4.9 1.1 302 15 301 165 14 0.4 14.9 13 09/24/2006 12:50:00 2.9 1.2 5.3 0.4 2.9 1.2 5.3 0.4 2.6 1 5.3 0.4 286 20 295 165 14.2 0.2 14.6 13.8 09/24/2006 13:00:00 3.7 1 5.7 0.4 3.6 1.1 5.7 0.4 2.9 1 4.9 0.4 283 19 280 165 12.5 0.5 13.8 11.9 09/24/2006 13:10:00 1.9 1 4.2 0.4 1.8 1 3.8 0.4 1.8 0.8 3.8 0.4 276 47 295 165 11.9 0.1 12.5 11.7 09/24/2006 13:20:00 2.7 1 4.6 0.4 2.8 1.1 4.6 0.4 2.2 1 4.6 0.4 270 30 292 165 12.7 0.4 13.5 11.9 09/24/2006 13:30:00 1.4 1.2 4.9 0.4 1.4 1.3 4.9 0.4 1.3 1 4.2 0.4 211 66 280 165 12.1 0.2 13 11.9 09/24/2006 13:40:00 1.5 1 4.6 0.4 1.6 1 5.3 0.4 1.6 0.8 3.4 0.4 155 61 281 165 12.9 0.2 13.3 12.5 09/24/2006 13:50:00 2.4 1.3 5.3 0.4 2.4 1.3 5.3 0.4 2.8 1 5.7 0.7 154 33 167 165 13.1 0.2 13.5 12.7 09/24/2006 14:00:00 3 0.8 4.6 1.1 2.9 0.8 4.9 1.1 3.3 0.8 5.3 0.7 152 18 126 165 12.4 0.3 13 11.9 09/24/2006 14:10:00 2.7 0.9 4.9 0.4 2.7 0.9 5.3 0.4 3.1 0.8 4.9 0.7 144 17 136 165 12.3 0 12.7 12.2 09/24/2006 14:20:00 3.1 0.7 5.3 0.4 3.2 0.8 4.9 0.4 3.5 0.6 5.3 1.9 142 17 162 165 12.5 0.2 13 11.9 09/24/2006 14:30:00 3.2 0.8 4.9 0.4 3.1 0.8 4.9 0.7 3.5 0.8 5.3 1.5 156 16 168 165 12.2 0 12.5 11.9 09/24/2006 14:40:00 2.4 0.9 4.9 0.4 2.4 0.9 4.9 0.4 2.7 0.8 4.9 0.7 138 21 149 165 12.8 0.2 13.3 12.5 09/24/2006 14:50:00 2.4 0.9 4.6 0.4 2.3 0.9 4.6 0.4 2.7 0.8 4.6 0.4 157 16 146 165 12.5 0.1 13 12.2 09/24/2006 15:00:00 2.3 0.7 3.8 0.7 2.2 0.8 4.2 0.4 2.7 0.5 4.6 1.1 160 15 179 165 12.1 0.1 12.7 11.9 09/24/2006 15:10:00 2.7 0.8 5.3 0.4 2.6 0.9 5.3 0.4 2.9 0.6 4.9 1.1 161 13 162 165 12.3 0.1 12.7 11.9 09/24/2006 15:20:00 2.1 1 4.2 0.4 2 1.1 4.6 0.4 2.8 0.9 4.9 0.7 161 15 143 165 11.9 0 12.2 11.7 09/24/2006 15:30:00 2.1 0.9 4.9 0.4 2.2 0.9 4.9 0.4 2.7 0.7 4.6 0.7 137 19 141 165 12.3 0.2 12.7 11.7 09/24/2006 15:40:00 2.2 0.7 4.6 0.4 2.1 0.7 4.6 0.4 2.8 0.6 4.2 1.1 162 11 166 165 11.9 0.4 12.7 11.1 09/24/2006 15:50:00 2.5 0.5 3.8 1.1 2.3 0.5 3.4 1.1 2.8 0.5 3.8 1.5 170 15 167 165 10.3 0.3 11.4 9.8 09/24/2006 16:00:00 1.1 0.6 2.6 0.4 1.4 0.6 3 0.4 1.6 0.5 3 0.4 145 14 149 165 10.4 0.3 11.1 9.8 09/24/2006 16:10:00 0.8 0.3 1.5 0.4 1.1 0.4 1.9 0.4 1.6 0.3 2.3 0.7 162 11 162 165 9.8 0.4 10.9 9 09/24/2006 16:20:00 0.7 0.3 1.5 0.4 0.8 0.4 1.9 0.4 1.3 0.3 1.9 0.7 162 7 157 165 8.9 0 9 8.8 09/24/2006 16:30:00 0.4 0.2 1.1 0.4 0.6 0.3 1.9 0.4 0.9 0.4 1.9 0.4 138 24 122 165 9.6 0.5 10.9 8.8 09/24/2006 16:40:00 1.1 0.6 2.6 0.4 1.3 0.6 2.6 0.4 1.6 0.5 2.6 0.4 126 15 157 165 10.3 0.2 10.9 9.6 09/24/2006 16:50:00 2.4 0.5 3.8 1.1 2.5 0.5 3.8 1.1 2.8 0.5 4.2 1.5 145 9 135 165 10.4 0 10.9 10.3 09/24/2006 17:00:00 1.9 0.5 3 0.4 1.9 0.5 3 0.7 2.4 0.4 3.4 1.5 156 10 146 165 10.1 0 10.6 9.8 09/24/2006 17:10:00 1.7 0.5 3 0.7 1.6 0.5 3 0.4 2.3 0.4 3.4 1.1 167 5 171 165 10 0 10.6 9.8 09/24/2006 17:20:00 1.2 0.6 2.3 0.4 1 0.7 2.3 0.4 1.9 0.4 3 1.1 164 2 165 165 9.7 0.1 10.1 9.6 09/24/2006 17:30:00 1.2 0.5 2.3 0.4 1.1 0.5 2.3 0.4 1.9 0.3 2.6 1.1 160 6 156 165 9.6 0 9.8 9.6 09/24/2006 17:40:00 1 0.4 1.9 0.4 0.7 0.4 1.5 0.4 1.6 0.3 2.3 1.1 156 5 164 165 9.6 0 10.1 9.3 09/24/2006 17:50:00 1.2 0.5 1.9 0.4 0.8 0.5 1.9 0.4 1.7 0.4 2.3 0.7 171 6 175 165 9.5 0 9.8 9.3 09/24/2006 18:00:00 0.6 0.5 1.9 0.4 0.6 0.4 1.9 0.4 1.2 0.5 2.3 0.4 166 1 168 165 9.3 0 9.6 9 09/24/2006 18:10:00 0.4 0.1 1.1 0.4 0.4 0 0.7 0.4 0.8 0.3 1.5 0.4 214 35 269 165 9.4 0 9.6 9.3 09/24/2006 18:20:00 0.9 0.4 1.9 0.4 0.6 0.4 1.5 0.4 1.2 0.3 1.9 0.4 295 10 301 165 9.3 0 9.6 9 09/24/2006 18:30:00 1 0.3 1.5 0.4 0.6 0.3 1.5 0.4 1.1 0.2 1.9 0.4 297 2 301 165 9.4 0 9.6 9.3 09/24/2006 18:40:00 0.6 0.3 1.1 0.4 0.4 0.1 1.1 0.4 1.1 0.4 2.3 0.4 292 9 296 165 9.1 0.1 9.3 8.8 09/24/2006 18:50:00 1.1 0.3 1.9 0.7 0.6 0.3 1.5 0.4 1.3 0.3 1.9 0.7 294 4 288 165 8.7 0 8.8 8.5 09/24/2006 19:00:00 1.5 0.2 2.3 1.1 1.4 0.3 1.9 0.7 1.6 0.3 2.3 1.1 294 2 294 165 8.6 0 8.8 8.5 09/24/2006 19:10:00 0.8 0.4 1.5 0.4 0.8 0.5 1.9 0.4 1.5 0.3 1.9 0.7 275 13 295 165 8.8 0 9 8.5 09/24/2006 19:20:00 1.3 0.3 2.3 0.7 1.4 0.5 2.6 0.4 1.7 0.4 2.6 0.7 286 13 297 165 8.9 0 9 8.5 09/24/2006 19:30:00 1.5 0.4 2.6 0.7 1.7 0.4 2.6 1.1 1.5 0.4 2.6 0.7 302 8 289 165 8.9 0 9 8.8 09/24/2006 19:40:00 3.1 0.7 4.2 1.5 3.3 0.6 4.6 1.5 2.7 0.7 4.2 1.1 286 11 290 165 8.5 0.1 8.8 8.3 09/24/2006 19:50:00 2.7 0.6 3.8 0.7 3 0.5 4.2 1.9 2.9 0.4 3.8 1.5 251 14 277 165 8.2 0.2 8.5 7.8 09/24/2006 20:00:00 2.5 0.4 3.4 1.5 2.9 0.3 3.4 2.3 3 0.2 3.4 2.3 252 8 236 165 8 0.2 8.5 7.3 09/24/2006 20:10:00 2.9 0.4 3.8 1.9 3.1 0.3 3.8 1.9 3.1 0.3 3.8 2.6 278 10 288 165 8.5 0 8.8 8.3 09/24/2006 20:20:00 3.2 0.3 4.2 2.6 3.4 0.3 4.2 2.6 3.5 0.3 4.2 3 281 4 284 165 8.5 0 8.5 8.3 09/24/2006 20:30:00 2.1 0.4 3 1.1 2.3 0.4 3 1.9 2.5 0.3 3.4 1.9 269 4 277 165 8.7 0 9 8.3 09/24/2006 20:40:00 2.1 0.2 2.6 1.9 2.2 0.2 2.6 1.5 2.2 0.5 3 1.1 284 8 279 165 8.8 0 9 8.5 09/24/2006 20:50:00 2.2 0.2 2.6 1.5 2.2 0.2 2.6 1.5 1.8 0.3 2.6 1.1 295 2 292 165 8.5 0.2 9 8 09/24/2006 21:00:00 2.4 0.2 3 1.9 2.4 0.2 3 1.9 2.1 0.3 3 1.1 293 2 288 165 8.8 0 9 8.5 09/24/2006 21:10:00 3.1 0.3 3.8 2.3 3.1 0.3 3.8 2.3 2.5 0.3 3.4 1.5 295 3 296 165 8.8 0 9 8.5 09/24/2006 21:20:00 2.8 0.3 3.4 2.3 2.9 0.3 3.4 2.3 2.2 0.3 3 1.5 296 3 301 165 8.7 0 9 8.5 09/24/2006 21:30:00 2.8 0.3 3.4 1.9 2.8 0.3 3.4 2.3 2.8 0.5 4.2 1.9 289 5 297 165 8.8 0 9 8.3 09/24/2006 21:40:00 2.6 0.5 3.4 1.9 2.6 0.5 3.8 1.9 2.9 0.4 3.8 1.9 276 3 278 165 8.8 0 9 8.5 09/24/2006 21:50:00 2.3 0.3 3 1.5 2.5 0.3 3.4 1.9 2.2 0.4 3.4 1.1 293 8 278 165 8.7 0 9 8.5 09/24/2006 22:00:00 2.6 0.4 3.4 1.9 2.8 0.4 3.4 1.9 2 0.3 3 1.1 295 4 297 165 8.9 0 9 8.5 09/24/2006 22:10:00 2.8 0.2 3.4 2.3 3 0.2 3.4 2.3 2.1 0.3 3 1.5 296 3 296 165 8.7 0 9 8.5 09/24/2006 22:20:00 2.8 0.3 3.4 2.3 3 0.3 3.8 2.3 2.2 0.3 3 1.5 299 2 301 165 8.7 0 9 8.5 09/24/2006 22:30:00 3 0.3 3.8 2.3 3.1 0.3 3.8 2.6 2.2 0.3 3 1.5 299 3 303 165 8.7 0 8.8 8.5 09/24/2006 22:40:00 2.7 0.2 3 2.3 2.8 0.2 3 2.3 2 0.3 2.6 1.5 298 1 298 165 8.8 0 9 8.5 09/24/2006 22:50:00 2.8 0.2 3.4 1.9 2.9 0.2 3.4 2.3 2 0.3 3 1.1 296 2 296 165 8.7 0 9 8.5 09/24/2006 23:00:00 3 0.2 3.4 2.3 3.2 0.2 3.8 2.6 2.3 0.3 3 1.5 297 3 294 165 8.7 0 9 8.3 09/24/2006 23:10:00 3 0.3 3.4 2.3 3.2 0.3 3.8 2.6 2.4 0.3 3 1.5 295 3 301 165 8.6 0.1 9 8 09/24/2006 23:20:00 3.3 0.3 4.2 2.6 3.4 0.3 4.2 2.6 3.3 0.5 4.6 1.9 288 3 285 165 8.7 0 9 8 09/24/2006 23:30:00 3.6 0.2 4.2 3 3.7 0.2 4.2 3.4 3.6 0.4 4.6 2.3 288 3 290 165 8.7 0.1 9 8.3 09/24/2006 23:40:00 3.4 0.3 3.8 2.6 3.5 0.3 4.2 2.6 3.1 0.4 4.2 1.9 292 4 299 165 8.5 0.1 9 8.3 09/24/2006 23:50:00 2.9 0.3 3.8 1.9 3.1 0.3 3.8 2.3 2.4 0.3 3.4 1.5 296 5 292 165 8.6 0 8.8 8.3 09/25/2006 00:00:00 2.5 0.3 3 1.9 2.6 0.3 3.4 1.9 2.8 0.3 3.8 1.9 286 2 286 165 8.7 0 9 8.5 09/25/2006 00:10:00 2.6 0.3 3 1.9 2.7 0.3 3.4 1.9 2.9 0.3 3.4 2.3 279 5 272 165 8.8 0 9 8.5 09/25/2006 00:20:00 3.1 0.4 3.8 2.3 3.3 0.4 4.2 2.6 3.3 0.4 4.2 2.3 285 3 283 165 8.5 0.2 9 8 09/25/2006 00:30:00 2.7 0.4 3.8 1.9 2.9 0.4 3.8 2.3 2.3 0.4 3.4 1.5 297 6 298 165 8.5 0.1 8.8 8.3 09/25/2006 00:40:00 2.8 0.2 3.4 2.3 2.9 0.2 3.8 2.6 2.5 0.4 3.4 1.5 292 4 292 165 8.7 0.1 9 8.3 09/25/2006 00:50:00 2.6 0.2 3 2.3 2.7 0.2 3.4 2.3 2.2 0.4 3 1.5 292 2 291 165 8.8 0.2 9 8.5 09/25/2006 01:00:00 1.8 0.3 2.6 1.1 1.9 0.4 2.6 1.1 1.9 0.3 2.6 1.1 281 8 296 165 8.9 0.2 9.3 8.5 09/25/2006 01:10:00 1.9 0.4 2.6 1.1 2 0.5 3.4 1.1 2.3 0.4 3.4 1.5 266 8 273 165 9.1 0.2 9.6 8.5 09/25/2006 01:20:00 1.5 0.4 2.3 0.7 1.6 0.5 2.6 0.4 1.9 0.5 2.6 0.7 273 9 279 165 9 0.2 9.3 8.5 09/25/2006 01:30:00 1.4 0.2 1.9 0.7 1.2 0.3 1.9 0.4 1.3 0.3 2.3 0.4 293 3 294 165 8.9 0.1 9 8.5 09/25/2006 01:40:00 1 0.2 1.5 0.7 0.4 0.2 1.1 0.4 1.1 0.2 1.5 0.4 305 0 305 165 9 0 9.3 8.5 09/25/2006 01:50:00 0.7 0.3 1.1 0.4 0.4 0 0.4 0.4 0.7 0.2 1.1 0.4 302 1 305 165 8.8 0.1 9 8.5 09/25/2006 02:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0.1 0.7 0.4 301 0 165 165 8.3 0.1 8.5 8 09/25/2006 02:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 301 0 165 165 8.3 0.2 8.8 7.8 09/25/2006 02:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 301 0 165 165 7.7 0.2 8.3 7.3 09/25/2006 02:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 301 0 165 165 8.1 0.2 8.5 7.5 09/25/2006 02:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 301 0 165 165 8.3 0.2 8.8 7.8 09/25/2006 02:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 301 0 165 165 8.2 0.2 8.8 7.8 09/25/2006 03:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0.1 0.7 0.4 22 38 165 165 8.3 0.2 8.8 7.8 09/25/2006 03:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 40 0 165 165 8.1 0.1 8.8 7.8 09/25/2006 03:20:00 1 0.5 2.3 0.4 0.7 0.5 1.9 0.4 1.1 0.5 2.3 0.4 40 5 48 165 8 0.1 8.3 7.5 09/25/2006 03:30:00 1.7 0.3 2.3 0.7 1.6 0.4 2.3 0.4 1.9 0.3 2.6 1.1 40 10 48 165 8.3 0.1 8.5 7.5 09/25/2006 03:40:00 2 0.2 2.3 1.5 1.9 0.2 2.3 1.5 1.9 0.2 2.3 1.5 29 2 32 165 8 0.2 8.3 7.5 09/25/2006 03:50:00 2.2 0.2 2.6 1.9 1.4 0.4 2.3 0.4 2.5 0.2 3 1.9 18 5 19 165 8 0 8.3 7.5 09/25/2006 04:00:00 1.8 0.4 2.6 1.1 1.2 0.3 2.3 0.4 2 0.4 2.6 1.1 22 9 16 165 8.2 0 8.5 7.8 09/25/2006 04:10:00 0.9 0.6 1.9 0.4 0.8 0.5 1.9 0.4 1.2 0.6 2.3 0.4 92 35 57 165 8.7 0.1 9 8 09/25/2006 04:20:00 0.5 0.3 1.1 0.4 0.4 0 0.7 0.4 0.7 0.4 1.5 0.4 85 43 43 165 8.7 0.1 9 8.3 09/25/2006 04:30:00 0.9 0.2 1.5 0.4 0.5 0.2 1.1 0.4 1.3 0.2 1.9 0.7 35 6 34 165 8.4 0.1 8.8 8 09/25/2006 04:40:00 0.7 0.3 1.5 0.4 0.4 0.2 1.5 0.4 1.1 0.2 1.9 0.7 129 15 68 165 8.3 0.2 8.8 7.8 09/25/2006 04:50:00 0.4 0.2 1.1 0.4 0.4 0 0.7 0.4 0.4 0.2 1.1 0.4 109 15 122 165 7.9 0.3 8.3 7.5 09/25/2006 05:00:00 0.4 0.1 1.1 0.4 0.4 0 0.4 0.4 0.5 0.3 1.5 0.4 75 17 44 165 7.9 0.1 8.3 7.5 09/25/2006 05:10:00 1.3 0.4 2.3 0.4 1 0.4 1.9 0.4 1.5 0.3 2.3 0.7 45 2 46 165 8 0.1 8.3 7.5 09/25/2006 05:20:00 1.3 0.4 2.3 0.7 1 0.5 1.9 0.4 1.6 0.3 2.3 0.7 40 8 34 165 8 0.1 8.3 7.5 09/25/2006 05:30:00 1.3 0.2 1.9 0.7 1.1 0.3 1.9 0.7 1.8 0.2 2.3 1.5 61 3 52 165 8.5 0.1 8.8 7.8 09/25/2006 05:40:00 1.8 0.2 2.3 1.1 1.6 0.3 2.3 0.7 2.1 0.2 2.6 1.5 49 5 55 165 8.5 0.1 9 8 09/25/2006 05:50:00 2 0.2 2.3 1.5 1.8 0.2 2.3 1.5 2.2 0.2 2.6 1.9 49 2 52 165 8.3 0 8.8 7.8 09/25/2006 06:00:00 2.2 0.1 2.6 1.9 2.1 0.2 2.3 1.9 2.5 0.2 3 2.3 49 1 48 165 8.2 0.1 8.5 7.8 09/25/2006 06:10:00 2 0.2 2.3 1.5 2 0.2 2.3 1.5 2.3 0.2 2.6 1.9 62 9 53 165 8.5 0.1 8.8 8 09/25/2006 06:20:00 1.8 0.2 2.3 1.1 1.9 0.3 2.6 1.1 2.2 0.2 2.6 1.5 75 11 90 165 8.4 0.2 8.8 7.8 09/25/2006 06:30:00 2.2 0.3 2.6 1.5 2.3 0.3 2.6 1.5 2.3 0.3 2.6 1.5 100 13 106 165 8.1 0.3 8.8 7.5 09/25/2006 06:40:00 2.2 0.3 2.6 1.1 2.1 0.4 2.6 1.1 2.3 0.3 3 1.5 128 9 111 165 7.6 0.2 8 7 09/25/2006 06:50:00 2 0.5 3 0.7 1.9 0.5 3 0.7 2 0.3 2.6 1.1 124 6 129 165 7.4 0.1 7.8 7 09/25/2006 07:00:00 2.1 0.3 3 1.5 2.1 0.3 3 1.5 2.1 0.2 3 1.5 115 11 128 165 7.7 0 8 7 09/25/2006 07:10:00 1.3 0.3 1.9 0.4 1.2 0.4 1.9 0.4 1.8 0.3 2.3 0.4 80 15 99 165 8.1 0 8.3 7.3 09/25/2006 07:20:00 0.5 0.2 1.1 0.4 0.4 0.1 1.1 0.4 0.8 0.4 1.9 0.4 48 20 81 165 8 0.1 8.5 7.5 09/25/2006 07:30:00 1.2 0.5 2.3 0.4 1 0.5 2.3 0.4 1.7 0.4 2.6 1.1 49 13 43 165 8.4 0.2 8.8 7.8 09/25/2006 07:40:00 2.5 0.3 3 1.9 2.4 0.3 3 1.9 2.7 0.3 3.4 2.3 46 12 54 165 8.5 0.1 8.8 8.3 09/25/2006 07:50:00 2.6 0.4 3.4 1.9 2.3 0.5 3.4 1.5 2.8 0.5 3.8 1.9 30 8 25 165 8.3 0 8.5 8 09/25/2006 08:00:00 2.1 0.3 3 1.1 2 0.4 3 1.1 2.1 0.4 3 1.1 107 29 83 165 8.3 0.1 8.5 8 09/25/2006 08:10:00 2.7 0.3 3.4 1.9 2.7 0.3 3.4 1.9 2.4 0.4 3 1.5 125 2 123 165 8.1 0.2 8.5 7.8 09/25/2006 08:20:00 2.1 0.4 2.6 1.1 1.9 0.4 2.6 1.1 2 0.3 2.6 1.5 130 5 126 165 7.8 0 8 7.3 09/25/2006 08:30:00 2.6 0.2 3 1.9 2.6 0.2 3 1.9 2.6 0.3 3 1.5 129 3 130 165 7.8 0 8 7.3 09/25/2006 08:40:00 2.5 0.2 3 1.9 2.5 0.2 3 1.9 2.5 0.2 3 1.9 130 2 133 165 7.9 0 8.3 7.3 09/25/2006 08:50:00 3 0.2 3.4 2.6 3 0.2 3.4 2.3 2.9 0.2 3.4 2.3 136 3 135 165 7.9 0.2 8.3 7.3 09/25/2006 09:00:00 2.7 0.3 3.4 1.9 2.5 0.3 3.4 1.9 2.5 0.2 3 1.9 144 4 141 165 8 0.2 8.5 7.3 09/25/2006 09:10:00 2.5 0.3 3.4 1.9 2.3 0.3 3.4 1.9 2.7 0.3 3.8 1.9 152 5 148 165 8.7 0.3 9.3 7.8 09/25/2006 09:20:00 2.3 0.4 3.4 1.1 2.1 0.4 3.4 1.1 2.3 0.3 3.4 1.5 147 6 148 165 9.1 0.1 9.3 8.8 09/25/2006 09:30:00 2.3 0.3 3 1.5 2.1 0.3 3 1.1 2.5 0.3 3.4 1.5 133 9 147 165 9.1 0 9.3 8.8 09/25/2006 09:40:00 2.7 0.8 4.2 1.1 2.5 0.9 4.2 0.7 2.8 0.7 4.2 1.5 134 10 128 165 9.2 0.1 9.6 8.8 09/25/2006 09:50:00 3.3 0.6 4.6 1.9 3.2 0.7 4.9 1.5 3.4 0.6 5.3 1.9 141 8 155 165 9.6 0.2 10.3 9 09/25/2006 10:00:00 4.3 0.6 6.1 2.6 4.2 0.6 6.1 2.3 4.4 0.6 6.5 2.6 152 8 156 165 10 0.3 10.3 9.3 09/25/2006 10:10:00 4.9 0.5 6.1 3.4 4.8 0.5 5.7 3 5 0.4 6.1 3.8 157 4 159 165 8.9 0.2 9.6 8.5 09/25/2006 10:20:00 3.8 0.4 5.7 3 3.8 0.4 5.3 2.6 3.9 0.4 4.9 3 154 9 148 165 8.5 0 8.8 8.3 09/25/2006 10:30:00 3.5 0.6 4.9 1.5 3.4 0.6 4.9 1.1 3.5 0.7 4.9 1.9 145 10 135 165 8.5 0 8.5 8.3 09/25/2006 10:40:00 3.7 0.6 4.9 1.9 3.6 0.6 4.9 1.9 3.7 0.6 4.9 2.3 143 12 157 165 8.5 0.1 8.8 8.3 09/25/2006 10:50:00 3.4 0.4 4.9 2.3 3.4 0.5 4.9 2.3 3.4 0.4 4.6 2.3 140 9 154 165 8.4 0.2 8.8 8 09/25/2006 11:00:00 3.8 0.4 4.9 2.6 3.8 0.5 4.9 2.6 3.9 0.5 4.9 2.6 142 8 136 165 8.5 0.1 9 8 09/25/2006 11:10:00 4.2 0.5 5.3 3 4.2 0.5 5.7 2.6 4.3 0.5 5.7 2.6 146 7 150 165 8.5 0.1 8.8 8.3 09/25/2006 11:20:00 4.1 0.4 5.3 3 4.1 0.4 5.3 3 4.2 0.5 5.3 3 139 7 132 165 8.5 0.1 8.5 8 09/25/2006 11:30:00 3.5 0.4 4.6 2.3 3.4 0.5 4.6 2.3 3.5 0.4 4.6 2.3 133 7 128 165 8.7 0.2 9 8.3 09/25/2006 11:40:00 3.3 0.3 4.2 2.3 3.2 0.3 4.2 2.3 3.4 0.3 4.6 2.3 129 6 139 165 9 0.2 9.6 8.5 09/25/2006 11:50:00 3.4 0.4 4.6 2.3 3.3 0.4 4.6 2.3 3.5 0.4 4.6 2.3 127 9 148 165 9.4 0 9.6 9 09/25/2006 12:00:00 3.6 0.5 5.3 2.6 3.5 0.5 5.3 2.3 3.6 0.5 5.3 2.3 129 7 116 165 9 0.2 9.3 8.5 09/25/2006 12:10:00 3.5 0.4 4.9 2.3 3.4 0.5 4.9 1.9 3.5 0.5 4.9 2.3 132 11 118 165 8.8 0.1 9 8.5 09/25/2006 12:20:00 3.8 0.5 4.9 2.6 3.7 0.6 4.9 2.3 3.8 0.5 4.9 2.6 129 9 126 165 8.9 0 9 8.3 09/25/2006 12:30:00 4.4 0.6 6.5 3 4.4 0.6 6.1 3.4 4.6 0.6 6.5 3.4 136 8 135 165 8.9 0 9 8.8 09/25/2006 12:40:00 5.4 0.4 6.8 4.6 5.3 0.4 6.5 4.2 5.4 0.5 6.8 4.2 145 6 153 165 8.7 0.1 9 8.3 09/25/2006 12:50:00 5.4 0.6 6.8 3.8 5.4 0.6 6.8 3.8 5.4 0.7 7.2 3.8 139 9 153 165 8.6 0 8.8 8.3 09/25/2006 13:00:00 5.3 0.5 6.5 3.8 5.3 0.6 6.8 3.4 5.2 0.6 6.8 3.4 132 8 127 165 8.9 0 9 8.5 09/25/2006 13:10:00 6 0.4 7.2 4.9 6 0.4 7.6 4.9 6.1 0.4 7.2 4.9 139 8 128 165 8.9 0 9.3 8.5 09/25/2006 13:20:00 6 0.5 7.2 4.6 6 0.5 7.6 4.6 6.2 0.5 7.2 4.9 144 5 139 165 8.8 0 9 8.5 09/25/2006 13:30:00 5.7 0.4 6.5 4.6 5.7 0.4 6.5 4.6 5.7 0.5 6.8 3.8 137 5 138 165 8.7 0.1 9 8.3 09/25/2006 13:40:00 5 0.5 6.1 3.8 5.1 0.5 6.1 4.2 5.1 0.5 6.1 3.8 136 7 136 165 8.7 0.1 9 8.3 09/25/2006 13:50:00 5.2 0.4 6.5 4.2 5.3 0.5 6.8 4.2 5.3 0.5 6.8 4.2 138 5 135 165 8.6 0 8.8 8.3 09/25/2006 14:00:00 4.7 0.5 6.8 3 4.8 0.5 6.5 3 4.8 0.6 6.5 3 132 8 128 165 8.6 0 8.8 8.3 09/25/2006 14:10:00 5.6 0.7 7.2 3.8 5.6 0.7 7.2 4.2 5.7 0.7 7.2 3.8 140 7 156 165 8.7 0 9 8.3 09/25/2006 14:20:00 5.6 0.6 7.2 3.4 5.8 0.6 7.2 3.4 5.5 0.6 7.2 3.8 116 13 111 165 8.5 0 8.8 8.3 09/25/2006 14:30:00 5.3 0.8 7.6 3 5.4 0.8 7.6 3 5.2 0.8 7.6 3.4 106 10 124 165 8.5 0 8.8 8.3 09/25/2006 14:40:00 5.2 0.7 6.8 2.3 5.3 0.8 6.8 2.6 5.2 0.7 6.8 3 110 9 108 165 8.3 0 8.5 7.8 09/25/2006 14:50:00 6.2 0.9 8 4.2 6.2 1 8.4 4.2 5.8 0.9 8.4 4.2 102 9 99 165 8.3 0 8.5 7.8 09/25/2006 15:00:00 6.6 0.9 8.4 4.2 6.7 1 8.8 3.8 6.3 1 8.4 3.8 106 7 102 165 8.8 0.3 9.3 8.3 09/25/2006 15:10:00 5.8 0.8 8 3.4 5.9 0.9 8.8 3.4 5.7 0.8 8 3.8 110 9 103 165 9 0.3 9.6 8.5 09/25/2006 15:20:00 6 0.8 8 4.2 6.1 0.8 8 4.2 5.7 0.8 7.6 3.8 110 8 122 165 8.3 0 8.5 8 09/25/2006 15:30:00 6.8 1.1 9.1 4.2 6.9 1.1 9.5 4.6 6.5 1.1 9.1 4.6 93 10 102 165 8.1 0 8.5 8 09/25/2006 15:40:00 6.9 0.7 8.4 4.9 6.9 0.7 8.8 4.9 6.6 0.7 8.4 4.6 100 7 93 165 8.5 0.1 8.5 8.3 09/25/2006 15:50:00 6.6 0.9 8.4 4.2 6.7 0.9 9.1 3.8 6.3 1 8.8 4.2 102 8 97 165 8.5 0 8.8 8.5 09/25/2006 16:00:00 7.2 0.7 8.8 4.9 7.2 0.8 9.1 4.9 6.9 0.8 8.8 4.9 99 6 91 165 8.4 0 8.5 8.3 09/25/2006 16:10:00 7.1 0.8 8.8 4.2 7.2 0.8 9.1 4.2 6.7 0.9 8.8 4.2 93 8 84 165 8.3 0 8.5 8 09/25/2006 16:20:00 7.5 0.9 9.1 5.3 7.6 1 9.5 5.3 7.2 1 9.1 4.2 88 6 86 165 8.1 0 8.3 7.8 09/25/2006 16:30:00 7.7 1 9.9 4.6 7.7 1.1 10.3 4.6 7.2 1 9.9 4.6 91 7 89 165 8 0 8.3 7.8 09/25/2006 16:40:00 8.6 1.1 11.1 5.3 8.8 1.2 11.1 5.3 8.1 1.2 10.7 4.9 91 7 94 165 7.9 0.1 8.3 7.5 09/25/2006 16:50:00 8.4 1 10.7 5.7 8.6 1.1 11.1 5.7 8 1.1 10.3 5.3 93 6 94 165 7.9 0.1 8.5 7.5 09/25/2006 17:00:00 8.8 0.9 11.1 6.1 9 0.9 11.5 6.1 8.3 1 10.7 6.1 92 7 91 165 7.9 0.1 8.3 7.5 09/25/2006 17:10:00 8.9 1 11.5 6.1 9.1 1.1 11.8 5.7 8.4 1.1 11.1 5.3 96 8 96 165 7.9 0.1 8.3 7.5 09/25/2006 17:20:00 9 1.2 11.5 5.7 9.1 1.3 11.8 5.7 8.6 1.2 11.5 5.7 93 7 93 165 7.9 0.1 8.5 7.5 09/25/2006 17:30:00 8.9 1.2 12.2 6.1 9.1 1.3 12.6 6.1 8.5 1.1 11.5 5.7 91 7 91 165 7.8 0.2 8.3 7.5 09/25/2006 17:40:00 9.1 1 11.5 6.5 9.3 1.1 11.8 6.5 8.5 1.2 11.5 5.7 92 8 98 165 7.8 0.2 8.3 7.5 09/25/2006 17:50:00 9.4 1.1 11.5 6.5 9.7 1.1 11.8 6.8 9 1 11.1 6.1 90 7 87 165 7.8 0.2 8 7.5 09/25/2006 18:00:00 9.6 1.2 12.2 5.7 9.8 1.3 12.2 6.1 9.1 1.2 11.8 5.7 87 6 81 165 7.8 0.2 8 7.5 09/25/2006 18:10:00 9.6 1 12.2 6.5 9.8 1.1 12.2 6.5 9.1 1.1 12.2 6.1 84 6 88 165 7.7 0.2 8 7.3 09/25/2006 18:20:00 9.1 1.1 13 6.5 9.4 1.2 13.3 6.5 8.9 1.1 12.2 6.5 80 7 83 165 7.7 0.2 8 7.3 09/25/2006 18:30:00 8.8 1.3 11.5 5.7 9.1 1.3 12.2 6.5 8.5 1.2 11.5 5.7 80 8 85 165 7.7 0.2 8 7.3 09/25/2006 18:40:00 9.6 1.2 11.5 6.1 9.8 1.3 11.8 6.1 9.3 1.3 13 6.1 83 7 70 165 7.8 0.2 8 7.3 09/25/2006 18:50:00 9.5 1.1 12.2 6.5 9.8 1.2 13 6.8 9.2 1.1 11.5 6.1 81 7 86 165 7.8 0.1 8 7.3 09/25/2006 19:00:00 9.8 1.3 12.6 6.1 10.1 1.3 12.6 5.7 9.3 1.3 12.6 6.1 80 7 78 165 7.9 0.1 8 7.3 09/25/2006 19:10:00 9.5 1.3 12.2 5.3 9.7 1.4 12.6 5.7 9.2 1.3 12.2 5.3 79 7 78 165 7.9 0 8 7.3 09/25/2006 19:20:00 9.3 1.5 14.5 5.7 9.5 1.6 14.9 5.7 9 1.5 13.7 5.7 78 9 63 165 7.7 0 7.8 7.5 09/25/2006 19:30:00 9.9 1.1 12.6 7.2 10.2 1.2 13.3 7.2 9.5 1.1 12.6 6.5 83 8 74 165 7.6 0 7.8 7.5 09/25/2006 19:40:00 10 1.5 14.1 6.1 10.2 1.5 14.5 5.7 9.4 1.3 13.3 6.1 85 10 94 165 7.6 0 7.8 7.3 09/25/2006 19:50:00 10.9 1.4 14.1 7.6 11.1 1.4 14.1 7.2 10.2 1.4 14.1 6.8 94 8 84 165 7.6 0 7.8 7.5 09/25/2006 20:00:00 10.6 1.2 13 7.2 10.8 1.2 13.3 7.6 10 1.2 12.6 6.5 89 8 85 165 7.6 0 7.8 7.5 09/25/2006 20:10:00 9.5 1.2 13 6.1 9.8 1.3 13 6.1 9.1 1.3 12.6 6.1 92 9 92 165 7.4 0.1 7.8 7.3 09/25/2006 20:20:00 11.3 1.5 14.1 6.5 11.6 1.5 14.9 5.7 10.9 1.5 14.5 6.5 98 8 101 165 7.1 0.2 7.5 6.5 09/25/2006 20:30:00 11.5 1.1 15.3 8.8 11.8 1.1 15.3 8 10.7 1.3 14.1 8 102 6 102 165 7.1 0.2 7.5 6.7 09/25/2006 20:40:00 10.3 1.4 13.7 6.1 10.5 1.4 13.7 6.8 9.7 1.3 13.7 5.7 86 9 96 165 6.7 0.1 7 6.2 09/25/2006 20:50:00 9.5 1.4 12.6 6.5 9.8 1.5 13.3 6.8 9.2 1.3 12.2 5.7 84 10 83 165 6.6 0.1 7 6 09/25/2006 21:00:00 6.8 1.2 9.9 3.8 7 1.2 10.3 3.8 6.7 1.2 9.9 4.2 64 10 70 165 6.6 0.1 6.7 6 09/25/2006 21:10:00 6.6 1.2 10.7 3.8 6.8 1.2 10.7 3.8 6.6 1.1 9.9 3.4 70 12 91 165 6.6 0.1 7 6.2 09/25/2006 21:20:00 6.7 1.2 10.7 4.6 7 1.1 11.1 4.9 6.7 1.2 11.1 4.2 72 11 88 165 6.7 0.2 7 6.2 09/25/2006 21:30:00 8.8 1.4 13.3 6.1 9.1 1.4 13.7 6.1 8.4 1.4 11.8 5.7 80 9 87 165 6.7 0.2 7 6.2 09/25/2006 21:40:00 9.1 1.6 13 5.3 9.4 1.6 13.3 5.3 9 1.5 12.2 5.7 77 8 83 165 6.7 0.1 7 6 09/25/2006 21:50:00 9.5 1.7 14.5 6.1 9.8 1.7 14.9 6.1 9.4 1.6 13.3 6.1 76 8 78 165 6.7 0 7 6.2 09/25/2006 22:00:00 8.6 1.5 13 5.3 8.8 1.5 13 5.3 8.3 1.5 12.6 4.9 62 11 69 165 6.7 0 7 6.2 09/25/2006 22:10:00 9.3 1.7 14.1 4.9 9.5 1.8 14.5 4.9 8.8 1.7 13 5.3 61 12 80 165 6.7 0 7 6.2 09/25/2006 22:20:00 8.8 1.7 13.7 4.6 9 1.8 13.7 4.6 8.8 1.6 13.3 4.9 69 12 75 165 6.7 0.1 7 6.2 09/25/2006 22:30:00 9.6 1.7 13.7 5.3 9.8 1.8 13.7 4.9 9.2 1.7 13.3 5.3 57 11 58 165 6.5 0.1 6.7 6 09/25/2006 22:40:00 7.5 1.6 13 4.2 7.6 1.6 13.3 4.2 7.2 1.7 13.7 3.8 53 11 54 165 6.4 0 6.5 6 09/25/2006 22:50:00 8.5 2.1 13.3 3.8 8.6 2.2 13.7 4.2 8 1.9 12.6 4.6 52 12 68 165 6.4 0 6.7 6 09/25/2006 23:00:00 9.3 2 15.3 5.3 9.4 2 15.6 5.3 9 1.6 14.5 5.7 45 10 45 165 6.6 0.1 7 6 09/25/2006 23:10:00 9.8 1.5 15.6 6.1 9.8 1.5 15.6 6.5 9.6 1.3 13.7 6.5 42 11 51 165 6.8 0.1 7 6.2 09/25/2006 23:20:00 10.5 1.8 15.6 6.5 10.5 1.8 15.6 6.5 10.1 1.8 14.9 5.7 44 10 34 165 7 0 7.3 6.7 09/25/2006 23:30:00 10.5 2.1 16.4 5.7 10.5 2.1 16.4 5.7 10 1.9 16.4 5.7 49 9 45 165 7.1 0 7.3 6.7 09/25/2006 23:40:00 10.3 1.7 14.1 5.7 10.3 1.7 14.5 5.7 10 1.7 15.3 5.3 58 11 50 165 7.2 0 7.3 6.5 09/25/2006 23:50:00 9.4 1.7 13.7 5.3 9.5 1.7 13.7 4.9 8.8 1.5 13.3 4.6 52 12 58 165 7.3 0 7.5 6.7 09/26/2006 00:00:00 9.5 1.8 13.7 4.9 9.5 1.8 13.7 4.6 9.1 1.6 13.7 4.9 44 11 43 165 7.2 0 7.5 6.5 09/26/2006 00:10:00 8.5 2.1 16.1 4.6 8.6 2.1 16.1 4.6 8.3 1.7 14.5 4.6 50 12 70 165 7.1 0.1 7.3 6.7 09/26/2006 00:20:00 10.3 1.8 15.6 6.5 10.3 1.8 16.1 6.1 10 1.6 14.5 6.1 44 11 58 165 7.1 0.1 7.5 6.5 09/26/2006 00:30:00 9.5 2.6 17.9 4.6 9.5 2.6 17.9 4.9 9 2.2 16.4 4.2 51 12 58 165 7.1 0.1 7.3 6.5 09/26/2006 00:40:00 10.4 1.8 14.5 6.1 10.4 1.9 14.5 5.7 9.9 1.9 14.5 6.1 47 11 36 165 7.1 0.1 7.3 6.5 09/26/2006 00:50:00 10.2 2.1 15.3 5.7 10.2 2.1 14.9 5.7 10 1.9 14.1 4.9 47 12 40 165 6.9 0.2 7.3 6.2 09/26/2006 01:00:00 11.5 1.9 16.4 6.8 11.5 2 16.8 6.5 11.3 1.9 16.1 6.5 34 10 39 165 7 0.2 7.3 6.2 09/26/2006 01:10:00 13.1 2.1 19.5 8 12.9 2.3 19.9 7.2 12.7 2.3 20.2 7.6 31 10 32 165 7.1 0.2 7.5 6.5 09/26/2006 01:20:00 11.9 2.3 17.9 6.5 11.7 2.4 17.9 6.5 11.5 2.2 17.6 6.8 30 10 30 165 7.2 0.2 7.5 6.7 09/26/2006 01:30:00 11.7 1.9 17.6 6.5 11.5 2 17.6 6.1 11.4 1.8 16.1 6.5 28 10 31 165 7.3 0.1 7.5 6.7 09/26/2006 01:40:00 11.5 1.8 16.1 7.2 11.2 1.9 15.6 6.8 11.2 1.8 15.6 5.7 25 9 19 165 7.3 0.2 7.5 7 09/26/2006 01:50:00 11.6 2.5 16.8 5.7 11.2 2.5 16.8 5.7 11.2 2.4 17.9 6.1 26 11 30 165 7.4 0.1 7.5 7 09/26/2006 02:00:00 13.6 2 18.7 8.4 13.3 2.2 18.7 8 13.3 2.2 19.1 8 26 9 29 165 7.4 0.1 7.8 7 09/26/2006 02:10:00 14.5 2.2 19.9 9.9 14 2.5 19.9 6.8 14.1 2 19.9 9.9 25 10 29 165 7.3 0.2 7.8 6.7 09/26/2006 02:20:00 13.6 1.9 19.1 9.1 12.6 2.3 18.7 6.5 13.2 2 18.7 8.8 18 8 21 165 7.4 0.1 7.5 7 09/26/2006 02:30:00 13 1.5 17.9 8 11.9 1.7 16.1 6.5 12.6 1.5 16.4 8.8 17 8 16 165 7.4 0 7.8 7 09/26/2006 02:40:00 13.7 1.8 17.6 9.1 12.7 2.2 17.2 6.8 13.2 1.7 17.2 9.1 18 8 19 165 7.6 0 7.8 7 09/26/2006 02:50:00 13.3 1.7 17.6 8.4 12.1 2 16.8 7.2 13 1.8 17.9 8 16 7 13 165 7.6 0 7.8 7.3 09/26/2006 03:00:00 12.1 1.3 16.1 8.4 10.4 1.7 15.3 6.5 11.9 1.3 16.1 7.6 13 7 14 165 7.6 0 7.8 7.3 09/26/2006 03:10:00 12.5 1.7 16.8 8.8 10.9 2.2 15.6 5.7 12.2 1.5 16.4 8.4 14 8 20 165 7.7 0 7.8 7.3 09/26/2006 03:20:00 12.2 1.4 15.6 8.8 11.1 1.7 15.3 6.8 11.9 1.5 15.6 8 16 7 11 165 7.8 0 8 7.3 09/26/2006 03:30:00 12.1 1.6 16.1 8 10.5 2 15.6 5.3 11.9 1.5 16.1 8.4 13 8 23 165 8 0.1 8.3 7.5 09/26/2006 03:40:00 11.4 1.3 15.3 8 9.4 1.6 13.3 5.7 11.4 1.4 14.9 8.4 11 6 14 165 8 0 8.3 7.5 09/26/2006 03:50:00 12.2 1.7 17.9 8 11.4 2.1 17.6 5.7 11.9 1.9 17.6 7.2 18 8 20 165 8.2 0 8.5 7.8 09/26/2006 04:00:00 10.6 1.3 14.1 6.8 9.4 1.7 13.3 4.9 10.4 1.2 13 7.6 14 8 6 165 8.3 0 8.5 8 09/26/2006 04:10:00 10.6 1.5 14.5 6.8 9.5 2 14.1 4.2 10.6 1.4 13.7 6.8 14 8 25 165 8.4 0 8.5 8.3 09/26/2006 04:20:00 10.4 1.1 14.1 8 7.7 1.3 13.7 4.9 10.8 1.1 13.7 8 6 6 18 165 8.3 0 8.5 8 09/26/2006 04:30:00 10.6 1.2 13.3 8 7.6 1 11.1 4.9 10.8 1.2 13.7 7.2 6 6 4 165 8.4 0 8.5 8 09/26/2006 04:40:00 9.9 1.1 13 7.2 7.5 1.3 11.1 4.9 10.3 1.2 13.3 7.2 7 7 3 165 8.5 0.1 8.8 8.3 09/26/2006 04:50:00 9 1 11.5 6.8 7.3 1.3 11.5 3.4 9.2 1 12.6 7.2 11 7 7 165 8.6 0 8.8 8.3 09/26/2006 05:00:00 8.2 1.3 11.5 5.7 6.7 1.4 9.9 3.8 8.5 1.2 11.1 6.1 10 7 8 165 8.7 0 9 8.5 09/26/2006 05:10:00 7 1 9.5 4.2 5.4 1.2 8.4 2.3 7.5 1 10.3 5.3 9 6 19 165 8.7 0 9 8.5 09/26/2006 05:20:00 8.1 0.7 9.9 6.1 6.2 1 9.5 3.8 8.5 0.7 11.1 6.5 10 5 10 165 8.8 0 9 8.3 09/26/2006 05:30:00 7.3 0.8 9.1 4.9 5.8 1 8.8 3.8 7.6 0.9 9.9 5.3 11 6 15 165 8.9 0 9 8.8 09/26/2006 05:40:00 6.3 0.8 8.4 4.6 4.2 1.1 7.2 2.3 6.7 0.7 8.4 4.9 5 6 5 165 9 0 9.3 8.8 09/26/2006 05:50:00 5.5 0.4 6.5 3.8 3.5 0.8 6.1 1.9 5.9 0.5 6.8 4.2 358 5 355 165 9 0 9.3 8.5 09/26/2006 06:00:00 4.8 0.8 6.1 2.6 3.3 0.8 5.7 1.5 5.2 1.1 6.8 2.6 348 15 3 165 9.1 0.1 9.3 8.5 09/26/2006 06:10:00 3 0.5 4.6 2.3 2.8 0.5 4.2 1.5 3.1 0.4 4.9 2.3 327 11 313 165 8.8 0 9 8.5 09/26/2006 06:20:00 2.5 0.4 3.4 1.9 2.2 0.4 3 1.5 2.5 0.5 3.8 1.5 310 10 326 165 8.8 0 9 8.5 09/26/2006 06:30:00 2.2 0.3 3.4 1.5 1.9 0.4 3 1.1 2.2 0.4 3 1.1 311 6 302 165 8.7 0 9 8.5 09/26/2006 06:40:00 3 0.5 4.6 1.9 2.7 0.6 4.2 1.5 2.8 0.5 3.8 1.5 309 5 305 165 8.7 0 9 8.5 09/26/2006 06:50:00 4.1 0.5 5.3 3 3.9 0.6 5.3 3 3.6 0.4 4.9 2.6 308 5 305 165 8.7 0 8.8 8.5 09/26/2006 07:00:00 4.8 0.4 6.1 3.8 4.8 0.4 6.1 3.4 4 0.4 5.3 3 303 4 300 165 8.7 0 8.8 8.5 09/26/2006 07:10:00 3.4 0.6 4.9 1.9 3.2 0.7 4.9 1.5 2.8 0.5 4.2 1.9 298 8 302 165 8.8 0 9 8.3 09/26/2006 07:20:00 3.3 0.5 4.6 1.9 3.1 0.6 4.6 1.5 2.8 0.5 4.6 1.5 298 7 308 165 9 0 9.3 8.5 09/26/2006 07:30:00 3.9 0.5 4.9 3 3.7 0.5 4.9 2.6 3.5 0.4 4.6 2.3 308 5 306 165 9 0.1 9.3 8.5 09/26/2006 07:40:00 2.7 0.6 4.2 1.5 2.4 0.7 4.2 0.7 2.6 0.6 4.2 1.1 307 4 306 165 9 0.2 9.3 8.5 09/26/2006 07:50:00 2.9 0.5 4.2 1.5 2.7 0.5 3.8 1.1 2.7 0.5 3.8 1.5 307 5 309 165 9.2 0.2 9.6 8.5 09/26/2006 08:00:00 3.3 0.4 4.2 2.3 3.1 0.5 3.8 1.9 3.3 0.5 4.2 2.3 316 6 313 165 9.3 0.2 9.6 9 09/26/2006 08:10:00 2.1 0.5 3 0.7 1.7 0.6 3 0.4 2.2 0.5 3.4 1.1 319 8 324 165 9.4 0.2 9.6 9 09/26/2006 08:20:00 1 0.7 2.6 0.4 0.8 0.6 2.3 0.4 1.2 0.7 2.6 0.4 47 76 125 165 9.5 0.2 9.8 9 09/26/2006 08:30:00 1.5 0.4 2.6 0.7 1.1 0.6 2.3 0.4 1.8 0.3 2.6 1.1 135 5 130 165 9.4 0.2 9.8 9 09/26/2006 08:40:00 0.9 0.3 1.5 0.4 0.4 0.2 1.1 0.4 1.4 0.3 2.3 0.7 142 13 128 165 9.4 0.2 9.8 9 09/26/2006 08:50:00 1 0.6 2.3 0.4 0.7 0.5 1.9 0.4 1.3 0.7 2.3 0.4 157 4 164 165 9.4 0.2 9.8 8.8 09/26/2006 09:00:00 1.2 0.3 1.9 0.4 0.4 0.2 1.5 0.4 1.6 0.2 2.3 1.1 159 5 150 165 9.4 0.2 9.6 9 09/26/2006 09:10:00 0.5 0.4 2.3 0.4 0.4 0.3 1.9 0.4 0.7 0.5 2.3 0.4 193 49 288 165 9.5 0.2 9.8 9 09/26/2006 09:20:00 1.1 0.5 2.3 0.4 0.7 0.5 2.3 0.4 1.6 0.4 2.6 0.7 280 7 292 165 9.6 0.1 9.8 9 09/26/2006 09:30:00 1 0.7 2.6 0.4 0.7 0.6 2.6 0.4 1.4 0.8 3 0.4 218 47 165 165 9.6 0.1 10.1 9.3 09/26/2006 09:40:00 3.3 0.7 5.3 2.3 3.1 0.8 5.3 1.5 3.6 0.7 5.7 2.6 168 5 164 165 9.6 0.1 10.1 9 09/26/2006 09:50:00 4.6 0.4 5.7 3 4.4 0.4 5.3 3 4.8 0.4 5.7 3.4 162 10 160 165 9.1 0.2 9.6 8.8 09/26/2006 10:00:00 5 0.5 6.1 3.4 4.8 0.5 6.1 3 5.2 0.5 6.5 4.2 160 5 145 165 8.9 0.2 9.3 8.5 09/26/2006 10:10:00 3.8 0.7 5.7 2.3 3.6 0.7 4.9 2.3 4 0.7 5.3 2.6 166 9 169 165 8.9 0.2 9.6 8.5 09/26/2006 10:20:00 2.8 0.4 3.8 1.9 2.6 0.4 3.4 1.5 3.1 0.3 3.8 2.3 166 7 164 165 8.9 0.2 9.3 8.5 09/26/2006 10:30:00 2.7 0.5 3.4 1.1 2.4 0.5 3.4 0.7 2.8 0.4 3.8 1.9 162 8 164 165 9.1 0.1 9.6 8.8 09/26/2006 10:40:00 2.3 0.6 3.4 0.7 1.9 0.7 3.4 0.4 2.5 0.6 3.8 1.5 162 14 153 165 9.3 0.2 9.6 8.8 09/26/2006 10:50:00 3.3 0.4 4.2 2.3 3.1 0.4 4.2 1.9 3.5 0.4 4.2 2.6 152 4 151 165 9.5 0.1 9.8 9 09/26/2006 11:00:00 1.8 1.2 3.4 0.4 1.7 1.1 3.4 0.4 2 1.2 3.4 0.4 151 7 149 165 9.6 0.1 9.8 9.3 09/26/2006 11:10:00 0.9 0.5 2.3 0.4 0.5 0.3 1.9 0.4 1.4 0.6 2.6 0.4 339 45 334 165 9.6 0.1 9.8 9.3 09/26/2006 11:20:00 0.6 0.4 1.9 0.4 0.4 0.1 1.1 0.4 0.7 0.5 1.9 0.4 230 49 166 165 9.9 0.2 10.6 9.6 09/26/2006 11:30:00 0.5 0.2 1.1 0.4 0.4 0 0.4 0.4 0.9 0.5 1.9 0.4 140 15 162 165 10.4 0.2 10.9 9.6 09/26/2006 11:40:00 1.3 1 3.8 0.4 1.1 1 3.8 0.4 1.7 1.1 4.2 0.4 156 23 139 165 11.2 0.3 11.7 10.3 09/26/2006 11:50:00 1 0.9 3.8 0.4 0.9 0.8 3.8 0.4 1.4 1 3.8 0.4 122 45 135 165 11.9 0.4 12.5 10.6 09/26/2006 12:00:00 1.7 0.8 3.4 0.4 1.4 0.9 3.8 0.4 2.2 0.8 3.8 0.4 130 17 141 165 11.5 0.1 11.9 11.4 09/26/2006 12:10:00 2.3 0.7 3.8 0.4 2.1 0.8 3.4 0.4 2.7 0.5 3.8 1.1 129 15 141 165 10.9 0.2 11.4 10.6 09/26/2006 12:20:00 2.6 0.7 4.6 1.1 2.5 0.8 4.9 0.7 2.9 0.8 4.9 1.1 121 8 119 165 10.7 0.1 11.1 10.6 09/26/2006 12:30:00 2.8 0.8 4.6 0.4 2.6 0.9 4.6 0.4 3.2 0.7 4.9 1.9 111 10 128 165 10.6 0 11.1 10.3 09/26/2006 12:40:00 2.4 0.9 3.8 0.4 2.2 1 3.8 0.4 2.7 0.7 4.2 0.7 117 12 134 165 10.5 0 10.9 10.3 09/26/2006 12:50:00 2.9 0.5 3.8 1.5 2.8 0.5 3.8 1.5 3.1 0.4 4.2 2.3 122 9 126 165 10.3 0.1 10.9 9.8 09/26/2006 13:00:00 3.4 0.5 4.2 1.9 3.3 0.5 4.6 1.5 3.6 0.5 4.6 2.3 126 8 125 165 9.8 0.1 10.1 9 09/26/2006 13:10:00 3.9 0.4 4.6 3 3.7 0.4 4.6 3 4.1 0.3 4.9 3.4 138 5 140 165 10 0 10.3 9.3 09/26/2006 13:20:00 3.8 0.3 4.9 3 3.7 0.4 4.6 2.6 3.9 0.4 4.9 3 129 6 118 165 9.6 0.1 9.8 9 09/26/2006 13:30:00 4 0.3 4.9 3.4 3.9 0.4 4.9 3 4.2 0.3 4.9 3.4 127 4 133 165 9.4 0 9.6 9 09/26/2006 13:40:00 3.8 0.5 5.3 2.3 3.6 0.6 4.9 1.9 3.9 0.4 4.9 3 134 8 125 165 9.4 0 9.6 9 09/26/2006 13:50:00 5.2 0.5 6.5 3.8 5.1 0.5 6.5 3.8 5.2 0.5 6.5 3.8 128 3 125 165 9.2 0 9.6 9 09/26/2006 14:00:00 4.2 0.7 6.1 3 4.1 0.7 5.7 2.6 4.4 0.6 6.1 3 134 7 135 165 9.2 0 9.6 9 09/26/2006 14:10:00 4.2 0.6 5.3 3 4.1 0.5 5.3 2.6 4.2 0.5 5.3 3 130 7 131 165 9.3 0 9.6 9 09/26/2006 14:20:00 4.2 0.5 5.3 3 4.1 0.5 5.7 3 4.3 0.5 5.3 3.4 125 8 117 165 9.4 0 9.6 9 09/26/2006 14:30:00 4 0.4 5.3 3 4 0.4 4.9 3 4.1 0.4 5.3 3 120 6 121 165 9.4 0 9.6 9.3 09/26/2006 14:40:00 4 0.5 4.9 2.3 3.9 0.5 4.9 2.3 4 0.5 4.9 2.6 118 5 118 165 9.4 0 9.6 9.3 09/26/2006 14:50:00 3.5 0.4 4.2 2.6 3.4 0.4 4.2 2.6 3.6 0.3 4.2 2.6 125 5 127 165 9.5 0 9.6 9.3 09/26/2006 15:00:00 3 0.4 3.8 2.3 2.9 0.4 3.8 1.9 3.2 0.4 4.2 2.3 123 6 122 165 9.6 0 9.8 9.3 09/26/2006 15:10:00 2 0.5 3 0.4 1.8 0.6 3 0.4 2.2 0.5 3.4 0.7 108 10 121 165 9.7 0 9.8 9.3 09/26/2006 15:20:00 1.4 0.5 2.6 0.4 0.9 0.5 2.3 0.4 1.7 0.5 2.6 0.4 85 17 84 165 9.8 0 9.8 9.6 09/26/2006 15:30:00 1.9 0.4 2.6 0.7 1.5 0.5 2.6 0.4 2.1 0.4 3.4 1.1 88 15 85 165 10 0 10.3 9.6 09/26/2006 15:40:00 2.4 0.5 3.8 1.1 2.1 0.6 3.4 0.4 2.5 0.6 3.8 1.1 102 13 90 165 10.1 0 10.3 9.8 09/26/2006 15:50:00 2.8 0.5 4.2 1.1 2.6 0.5 3.8 0.7 3 0.5 4.2 1.5 105 8 111 165 10.2 0 10.6 9.8 09/26/2006 16:00:00 1 0.6 2.6 0.4 0.7 0.5 2.3 0.4 1.5 0.6 3 0.4 52 33 7 165 10.3 0.1 10.9 9.6 09/26/2006 16:10:00 2.1 0.8 3.4 0.4 1.7 0.8 3 0.4 2.3 0.8 3.8 0.4 81 51 18 165 10.5 0 10.9 9.8 09/26/2006 16:20:00 1.8 0.5 2.6 0.4 1.4 0.6 2.6 0.4 2.1 0.5 3 0.7 126 9 122 165 10.2 0 10.6 9.8 09/26/2006 16:30:00 2.5 0.5 3.8 1.1 2.2 0.6 3.4 0.7 2.6 0.4 3.4 1.5 120 7 122 165 10.1 0 10.3 9.6 09/26/2006 16:40:00 2.6 0.3 3.4 1.9 2.3 0.3 3 1.5 2.9 0.3 3.4 2.3 124 7 119 165 10.1 0 10.3 9.8 09/26/2006 16:50:00 2.2 0.4 3 0.7 1.8 0.5 2.6 0.4 2.4 0.3 3 1.5 125 9 120 165 9.9 0 10.1 9.6 09/26/2006 17:00:00 2.5 0.4 3.4 1.5 2.2 0.5 3.4 1.1 2.7 0.3 3.8 1.9 135 5 141 165 9.9 0 10.1 9.6 09/26/2006 17:10:00 2.7 0.3 3.4 1.9 2.4 0.4 3.4 1.5 2.9 0.3 3.8 2.3 141 5 130 165 9.8 0 9.8 9.3 09/26/2006 17:20:00 1.9 0.4 2.6 1.1 1.4 0.5 2.3 0.4 2.1 0.3 3 1.5 141 9 135 165 9.8 0 9.8 9.3 09/26/2006 17:30:00 1.8 0.3 2.6 1.1 1.3 0.4 2.3 0.4 2.1 0.2 2.6 1.5 148 6 155 165 9.8 0 10.1 9.3 09/26/2006 17:40:00 1.8 0.2 2.6 1.1 1.3 0.3 2.3 0.4 2.2 0.2 3 1.5 155 7 144 165 9.8 0 10.1 9.6 09/26/2006 17:50:00 1.8 0.4 2.6 1.1 1 0.5 2.3 0.4 2.1 0.2 2.6 1.5 163 2 164 165 9.7 0.1 10.1 9.3 09/26/2006 18:00:00 1.4 0.4 2.6 0.4 0.6 0.4 1.9 0.4 1.7 0.3 2.3 0.7 170 4 164 165 9.6 0.1 9.8 9 09/26/2006 18:10:00 2.3 0.5 3.8 1.1 1.8 0.6 3 0.4 2.4 0.4 3 1.5 169 8 172 165 9.6 0.2 9.8 9 09/26/2006 18:20:00 2.2 0.3 2.6 1.5 1.6 0.3 2.3 0.7 2.3 0.2 3 1.9 168 3 164 165 9.6 0 9.8 9.3 09/26/2006 18:30:00 2.7 0.2 3 1.9 2.2 0.2 2.6 1.5 2.8 0.2 3.4 2.3 161 3 164 165 9.6 0 9.8 9.3 09/26/2006 18:40:00 2.6 0.3 3 1.9 2.1 0.3 2.6 1.5 2.9 0.3 3.4 2.3 161 9 164 165 9.6 0 9.8 9.3 09/26/2006 18:50:00 2.4 0.2 3 1.9 2 0.3 2.6 1.5 2.6 0.2 3 2.3 157 5 156 165 9.5 0 9.6 9.3 09/26/2006 19:00:00 2.5 0.2 3 1.9 1.9 0.2 2.6 1.5 2.5 0.2 3 1.9 164 3 165 165 9.4 0 9.6 9 09/26/2006 19:10:00 2.6 0.2 3 1.9 2 0.3 2.6 1.1 2.5 0.3 3 1.9 169 4 169 165 9.3 0 9.6 9 09/26/2006 19:20:00 2.5 0.4 3 1.9 1.9 0.4 2.6 1.1 2.5 0.2 3 1.9 178 2 180 165 9.3 0.1 9.6 9 09/26/2006 19:30:00 2.9 0.3 3.8 2.3 2.4 0.4 3.4 1.5 2.9 0.3 3.4 2.3 176 2 177 165 9.4 0.1 9.8 9 09/26/2006 19:40:00 3.2 0.2 3.4 2.6 2.7 0.2 3 2.3 3.3 0.2 3.8 3 171 2 173 165 9.3 0.1 9.6 9 09/26/2006 19:50:00 2.9 0.2 3.4 2.6 2.4 0.2 2.6 1.9 3 0.2 3.4 2.6 170 4 172 165 9.4 0 9.6 9 09/26/2006 20:00:00 2.8 0.4 3.4 1.9 2.3 0.4 3 1.5 2.7 0.3 3.4 2.3 174 6 177 165 9.4 0.1 9.6 9 09/26/2006 20:10:00 3.3 0.2 3.8 3 2.9 0.2 3.4 2.3 3.4 0.3 3.8 2.6 179 2 177 165 9.5 0.1 9.8 9 09/26/2006 20:20:00 3.2 0.4 3.8 2.3 2.8 0.4 3.4 1.9 3.1 0.4 3.8 2.3 180 3 177 165 9.6 0 9.8 9.3 09/26/2006 20:30:00 2.1 0.2 3 1.5 1.5 0.3 2.3 0.7 2.2 0.3 2.6 1.5 172 5 174 165 9.4 0.1 9.8 9 09/26/2006 20:40:00 2.2 0.2 2.6 1.5 1.6 0.3 2.3 0.7 2.3 0.2 2.6 1.9 178 2 177 165 9.4 0.1 9.6 9 09/26/2006 20:50:00 1.8 0.4 3 0.7 1.1 0.4 2.6 0.4 1.8 0.4 2.6 0.7 194 8 198 165 9.4 0.1 9.6 9 09/26/2006 21:00:00 1.4 0.3 2.3 0.7 0.7 0.4 1.9 0.4 1.7 0.2 2.3 1.1 225 9 223 165 9.5 0.1 9.8 9.3 09/26/2006 21:10:00 1.6 0.5 2.6 0.4 1 0.6 2.3 0.4 1.6 0.4 2.6 0.7 285 19 297 165 9.6 0.1 9.8 9.3 09/26/2006 21:20:00 2 0.3 2.6 1.1 1.5 0.3 2.3 0.7 1.6 0.2 2.3 1.1 300 4 297 165 9.5 0.1 9.8 9.3 09/26/2006 21:30:00 1.7 0.4 2.3 1.1 1.1 0.5 1.9 0.4 1.4 0.2 2.3 0.7 302 4 301 165 9.5 0.1 10.1 9 09/26/2006 21:40:00 3.1 0.6 4.6 1.9 2.8 0.6 4.6 1.1 2.2 0.5 3.4 1.1 300 3 301 165 9.6 0.1 9.8 9 09/26/2006 21:50:00 4.6 0.5 5.7 3.4 4.4 0.5 5.7 3.4 3.4 0.4 4.9 2.3 298 3 292 165 9.6 0.1 9.8 9.3 09/26/2006 22:00:00 5 0.5 6.1 3.4 4.8 0.5 5.7 3.4 4 0.5 5.3 2.6 305 5 305 165 9.6 0.1 9.8 9 09/26/2006 22:10:00 5.5 0.4 6.8 4.6 5.4 0.4 6.8 4.6 4.7 0.5 6.5 3 308 4 313 165 9.6 0.1 10.1 9.3 09/26/2006 22:20:00 6.2 0.5 7.6 4.9 6 0.5 7.6 4.6 5.2 0.7 7.2 3.4 307 5 301 165 9.6 0.1 9.8 9.3 09/26/2006 22:30:00 5.8 0.6 7.2 4.2 5.7 0.6 7.2 4.2 4.6 0.6 6.5 3 304 5 304 165 9.6 0.1 9.8 9.3 09/26/2006 22:40:00 6.1 0.5 7.2 4.6 5.9 0.5 7.2 4.6 4.8 0.7 6.5 3 302 5 305 165 9.6 0.1 9.8 9.3 09/26/2006 22:50:00 6.5 0.5 8 4.9 6.4 0.5 7.6 4.9 5 0.6 6.8 3.4 303 5 296 165 9.5 0.2 9.6 9 09/26/2006 23:00:00 6.5 0.7 8.4 4.9 6.4 0.7 8 4.6 5.4 0.8 8 3.8 303 8 310 165 9.4 0.2 9.6 9 09/26/2006 23:10:00 6.8 1 9.5 4.6 6.7 1 9.1 4.6 6.5 1 9.1 4.2 311 6 311 165 9.4 0.2 9.6 9 09/26/2006 23:20:00 7.1 0.6 8.4 5.3 7 0.6 8.4 5.3 6.2 0.7 8 3.8 309 6 300 165 9.4 0.1 9.6 9 09/26/2006 23:30:00 7 0.7 8.4 4.9 6.8 0.7 8.4 4.9 5.9 0.8 8 3.4 308 7 312 165 9.3 0.1 9.6 9 09/26/2006 23:40:00 6.1 0.8 8 3.8 6 0.8 8 3.8 5 0.9 8 3 302 7 316 165 9.2 0.1 9.8 8.8 09/26/2006 23:50:00 6.1 1.3 8.4 3.4 6 1.3 8.8 3.4 4.6 0.9 6.8 2.3 299 6 300 165 9.2 0.1 9.6 8.8 09/27/2006 00:00:00 6.3 0.7 8.4 4.6 6.3 0.7 8 4.6 4.8 0.6 7.2 3.4 302 6 300 165 9.2 0.2 9.6 8.8 09/27/2006 00:10:00 4.1 0.8 6.1 1.9 4 0.8 6.5 1.9 3.5 0.8 5.7 1.5 303 9 302 165 9.2 0.2 9.6 8.8 09/27/2006 00:20:00 3.9 0.8 5.7 2.3 3.8 0.8 5.7 1.9 3.3 0.8 5.3 1.9 298 10 297 165 9.1 0.2 9.6 8.5 09/27/2006 00:30:00 4.8 1.3 7.2 1.9 4.8 1.3 7.2 1.9 4.3 1.4 7.2 1.5 288 9 283 165 9 0.3 9.3 8.5 09/27/2006 00:40:00 4.6 1 6.8 2.6 4.6 1 7.6 2.6 4 0.9 6.5 2.3 289 12 310 165 9 0.2 9.3 8.5 09/27/2006 00:50:00 5.2 0.8 7.2 3 5.2 0.8 6.8 3 4.5 0.9 6.8 2.6 291 9 296 165 9 0 9 8.5 09/27/2006 01:00:00 5.8 0.6 7.2 3.8 6.2 0.6 8 4.2 5.8 0.7 7.6 3 279 7 282 165 8.9 0 9 8.8 09/27/2006 01:10:00 6.6 1 8.4 3.8 7.6 0.6 9.1 5.7 7.3 0.6 8.8 5.3 272 4 275 165 9 0.1 9.3 8.5 09/27/2006 01:20:00 7.6 0.9 9.9 5.3 8.1 0.5 9.9 6.8 7.9 0.5 9.9 6.1 278 6 281 165 9 0 9.3 8.5 09/27/2006 01:30:00 8.1 0.5 9.5 6.5 8.1 0.5 9.5 6.5 7.7 0.7 9.1 4.6 286 5 292 165 8.9 0 9 8.5 09/27/2006 01:40:00 8 0.5 9.5 6.5 8.1 0.5 9.5 6.8 7.6 0.7 9.1 5.7 283 5 277 165 8.9 0 9 8.8 09/27/2006 01:50:00 7.4 0.7 9.5 6.1 7.5 0.7 9.5 6.1 6.8 0.8 9.5 4.6 286 5 290 165 9 0 9.3 8.8 09/27/2006 02:00:00 6.4 0.6 8 4.9 6.4 0.6 8 4.9 5 0.7 7.2 3.4 295 5 298 165 8.9 0 9 8.8 09/27/2006 02:10:00 7.1 0.5 8.4 5.7 7 0.5 8.4 5.7 5.2 0.6 7.2 4.2 302 4 300 165 8.9 0 9 8.5 09/27/2006 02:20:00 6.8 0.7 8.8 4.9 6.8 0.7 8.4 4.9 5.4 0.8 7.6 3.8 301 6 302 165 8.8 0 9 8.5 09/27/2006 02:30:00 7.2 1 9.9 4.6 7.1 1.1 9.9 4.6 6 1 8.8 3.8 303 7 305 165 8.7 0 9 8.5 09/27/2006 02:40:00 7.2 0.9 10.3 5.3 7.1 0.9 10.3 5.3 5.9 1 9.5 4.2 294 7 289 165 8.9 0 9 8.5 09/27/2006 02:50:00 7.9 1.1 10.3 5.3 7.8 1.2 10.3 4.9 6.4 1.4 9.9 3.8 294 6 297 165 9 0 9.3 8.8 09/27/2006 03:00:00 7.2 0.7 8.8 4.9 7.2 0.8 9.1 4.9 6.2 1 8.8 3.8 292 6 305 165 8.8 0 9 8.5 09/27/2006 03:10:00 7.2 0.6 8.4 5.3 7.2 0.7 8.8 5.3 6.1 1.2 9.1 3.4 291 4 286 165 8.9 0 9 8.5 09/27/2006 03:20:00 6.7 0.4 8 5.3 6.8 0.4 8 5.3 5.5 0.7 7.2 3.8 292 5 295 165 8.9 0 9 8.5 09/27/2006 03:30:00 6.9 0.5 8 5.7 7 0.5 8.4 5.3 5.9 0.8 8 3.8 289 4 289 165 8.8 0 9 8.5 09/27/2006 03:40:00 6.9 0.7 8.4 5.3 7 0.7 8.8 5.3 6.4 1 8.4 3.8 284 5 284 165 8.9 0 9 8.5 09/27/2006 03:50:00 6.8 0.5 8 5.3 6.8 0.5 8 5.3 6 0.9 7.6 3.4 290 4 287 165 8.7 0 9 8.5 09/27/2006 04:00:00 6.3 0.4 6.8 5.3 6.3 0.4 7.2 5.3 4.7 0.5 6.5 3.8 299 4 295 165 8.6 0.1 8.8 8.3 09/27/2006 04:10:00 6.4 0.5 8.4 5.3 6.4 0.5 8.4 5.3 4.8 0.7 6.8 3.4 297 5 293 165 8.5 0.1 9 8 09/27/2006 04:20:00 5.4 0.4 6.5 4.2 5.4 0.4 6.5 4.2 5.2 0.6 6.5 3.4 287 5 300 165 8.9 0.1 9.3 8.5 09/27/2006 04:30:00 5.3 0.5 6.1 3.8 5.3 0.5 6.5 3.8 4.6 0.8 6.1 3 290 6 281 165 9.1 0 9.3 8.8 09/27/2006 04:40:00 5.2 0.4 6.1 3.4 5.3 0.4 6.1 3.8 4 0.5 5.7 3 295 3 293 165 9 0.1 9.3 8.5 09/27/2006 04:50:00 4.6 0.4 5.7 3.8 4.7 0.4 5.7 3.8 4.3 0.4 5.3 3.4 289 3 290 165 9 0 9.3 8.5 09/27/2006 05:00:00 4.3 0.5 5.7 3.4 4.3 0.5 6.1 3 3.5 0.6 4.9 2.3 296 5 300 165 9.1 0 9.6 8.8 09/27/2006 05:10:00 3.5 0.5 4.9 2.3 3.4 0.5 4.6 2.3 2.9 0.4 3.8 1.1 294 7 296 165 8.9 0 9 8.5 09/27/2006 05:20:00 2.1 0.4 3 0.7 2.4 0.4 3.4 1.1 2.7 0.4 3.4 1.9 266 8 281 165 8.7 0 9 8.5 09/27/2006 05:30:00 2.7 0.8 4.2 1.1 2.5 0.8 4.2 0.7 2.8 0.5 4.2 1.5 243 13 241 165 8.7 0.1 9 8.3 09/27/2006 05:40:00 3.3 0.6 4.6 1.5 3.8 0.6 4.6 1.5 3.9 0.8 4.9 1.9 262 8 265 165 8.6 0 8.8 8.3 09/27/2006 05:50:00 3.7 0.4 4.2 2.6 3.6 0.4 4.2 2.6 3.1 0.7 4.6 1.5 291 9 273 165 8.5 0.1 8.8 8.3 09/27/2006 06:00:00 1.6 0.5 3 0.4 1.4 0.5 3 0.4 1.7 0.3 2.6 0.7 271 18 304 165 8.5 0 8.8 8.3 09/27/2006 06:10:00 1.2 0.3 1.9 0.7 0.7 0.4 1.5 0.4 1.7 0.3 2.3 1.1 249 8 240 165 8.7 0 9 8.3 09/27/2006 06:20:00 0.9 0.4 1.9 0.4 0.4 0.2 1.1 0.4 1.1 0.5 1.9 0.4 276 5 269 165 8.9 0 9 8.5 09/27/2006 06:30:00 0.6 0.4 2.3 0.4 0.4 0.3 1.9 0.4 0.7 0.5 2.3 0.4 239 58 165 165 8.7 0.1 9 8.5 09/27/2006 06:40:00 1.9 0.4 2.6 1.1 1.4 0.6 2.6 0.4 2.1 0.3 2.6 1.5 166 8 164 165 8.5 0.2 9 7.8 09/27/2006 06:50:00 2.5 0.5 3.4 1.1 2.1 0.6 3.4 0.4 2.5 0.4 3.4 1.5 179 5 182 165 8.4 0.1 8.5 8 09/27/2006 07:00:00 3.2 0.3 4.2 2.3 3 0.3 4.2 2.3 3.3 0.4 4.6 2.3 185 5 180 165 8.3 0 8.5 7.8 09/27/2006 07:10:00 2.7 0.3 3.4 1.9 2.4 0.3 3 1.5 2.8 0.3 3.4 2.3 193 6 190 165 8.1 0 8.5 7.8 09/27/2006 07:20:00 2.9 0.4 4.2 1.9 2.7 0.5 4.2 1.5 2.9 0.3 3.8 2.3 200 9 204 165 8.3 0 8.5 7.8 09/27/2006 07:30:00 2.4 0.4 3.4 1.9 2.1 0.4 3.4 1.5 2.5 0.4 3.4 1.5 202 3 208 165 8.2 0 8.5 7.8 09/27/2006 07:40:00 3 0.3 3.8 2.3 2.7 0.3 3.8 1.9 3.1 0.3 3.8 2.6 198 3 199 165 8.4 0.1 8.8 7.8 09/27/2006 07:50:00 3.4 0.3 4.6 2.6 3.2 0.4 4.2 2.3 3.4 0.4 4.6 2.3 205 5 198 165 8.7 0 8.8 8.3 09/27/2006 08:00:00 3.2 0.3 3.8 1.9 2.9 0.3 3.4 1.5 3.1 0.3 3.8 2.3 195 9 202 165 8.5 0.1 8.8 8 09/27/2006 08:10:00 3.1 0.5 4.2 1.9 2.7 0.5 4.2 1.9 3.1 0.4 4.2 2.3 162 9 185 165 7.8 0.4 8.5 7 09/27/2006 08:20:00 3.8 0.4 4.9 2.3 3.4 0.4 4.2 1.9 3.6 0.4 4.6 2.6 165 8 163 165 7.3 0.2 7.8 6.7 09/27/2006 08:30:00 2.8 0.3 3.8 1.9 2.4 0.4 3.4 1.5 2.9 0.3 3.8 2.3 187 6 194 165 7.8 0.2 8.5 7 09/27/2006 08:40:00 3.7 0.8 5.7 1.5 3.4 0.9 5.3 1.1 3.7 0.8 5.3 1.5 163 12 162 165 8 0.2 8.5 7.3 09/27/2006 08:50:00 4.7 0.3 5.3 3.8 4.3 0.3 4.9 3.8 4.7 0.3 5.3 3.8 171 8 157 165 7.5 0.1 7.8 7 09/27/2006 09:00:00 4.3 0.3 4.9 3.4 4.1 0.3 4.9 3.4 4.4 0.3 5.3 3.8 186 3 180 165 7.8 0.2 8.3 7.3 09/27/2006 09:10:00 3.8 0.5 4.9 2.3 3.7 0.5 4.9 2.3 3.7 0.6 4.9 2.3 203 9 196 165 8.1 0 8.5 7.8 09/27/2006 09:20:00 5 0.5 6.1 3.8 4.8 0.5 6.1 3.4 5 0.6 6.1 3.4 192 7 193 165 8.2 0 8.5 7.8 09/27/2006 09:30:00 5.8 1.3 8.4 3 5.6 1.3 8.4 2.6 5.9 1.3 8.8 3.4 187 9 193 165 8 0 8.3 7.5 09/27/2006 09:40:00 7.4 0.7 8.8 5.3 7.4 0.7 9.1 5.3 7.3 0.8 9.1 5.7 197 5 192 165 8.1 0 8.3 7.8 09/27/2006 09:50:00 5.6 1 8 3.4 5.6 1.1 8.4 3.4 5.6 1 8.4 3.8 195 5 196 165 8 0.1 8.3 7.8 09/27/2006 10:00:00 4.7 0.6 6.5 3.8 4.5 0.6 6.1 3.4 4.7 0.5 6.1 3.4 185 7 183 165 7.8 0.1 8.3 7.3 09/27/2006 10:10:00 5.5 0.5 6.8 4.6 5.2 0.5 6.5 4.2 5.5 0.5 6.8 4.6 174 5 174 165 7.6 0 7.8 7.3 09/27/2006 10:20:00 6.8 0.5 8 5.7 6.5 0.5 7.2 5.3 6.7 0.5 8 5.3 172 5 172 165 7.8 0.1 8 7.3 09/27/2006 10:30:00 8.1 1.5 11.1 4.6 7.9 1.5 10.7 4.6 8.1 1.5 10.7 4.9 164 7 164 165 7.7 0 8 7.3 09/27/2006 10:40:00 8.3 0.7 9.9 6.5 8 0.7 9.5 6.5 8.3 0.8 9.9 6.5 167 6 164 165 7.5 0.1 7.8 7 09/27/2006 10:50:00 9.2 0.6 10.7 7.6 8.9 0.6 10.3 7.2 9.4 0.7 11.5 6.8 171 5 173 165 7.4 0.1 7.8 7 09/27/2006 11:00:00 8.3 1 10.3 6.5 8 1 9.9 6.1 8.4 1 10.3 6.5 173 8 180 165 7.3 0.1 7.5 6.7 09/27/2006 11:10:00 7.7 0.6 8.8 5.7 7.3 0.5 8.4 5.3 7.8 0.5 9.1 6.5 171 5 172 165 7.3 0.1 7.5 7 09/27/2006 11:20:00 7 0.4 8 5.7 6.7 0.4 7.6 5.7 7.2 0.4 8 5.7 176 5 184 165 7.7 0 8 7 09/27/2006 11:30:00 7.5 0.5 8.8 5.7 7.1 0.4 8.4 5.3 7.6 0.6 9.1 6.5 175 6 175 165 7.7 0 8 7.3 09/27/2006 11:40:00 8.3 0.9 10.7 5.7 7.9 0.9 10.3 5.7 8.4 0.9 10.7 5.7 174 9 165 165 7.4 0.1 7.8 7 09/27/2006 11:50:00 6.4 0.6 8 4.9 6.1 0.6 7.6 4.9 6.5 0.6 8.4 4.9 172 11 181 165 7.3 0.1 7.5 6.7 09/27/2006 12:00:00 8.2 1.3 11.1 5.7 8 1.3 10.7 5.3 8.4 1.3 11.1 5.3 170 7 172 165 7.1 0 7.3 6.5 09/27/2006 12:10:00 10.4 0.8 13 8 10.1 0.7 12.2 8 10.6 0.8 12.2 8.4 169 7 172 165 7.1 0 7.3 6.2 09/27/2006 12:20:00 10.7 0.7 12.2 9.1 10.5 0.6 12.2 8.8 11 0.8 12.6 8.4 171 8 161 165 7.1 0 7.3 6.2 09/27/2006 12:30:00 8.5 1.1 11.1 6.5 8.3 1.1 10.7 6.5 8.6 1.1 11.5 6.1 168 4 166 165 6.9 0 7.3 6.7 09/27/2006 12:40:00 7.7 0.7 9.1 6.1 7.6 0.6 8.8 6.1 7.8 0.7 9.5 6.1 167 7 169 165 6.9 0 7 6.5 09/27/2006 12:50:00 7.9 0.4 8.8 6.5 7.7 0.4 8.8 6.5 8.1 0.5 9.1 6.5 167 3 162 165 6.8 0 7 6.7 09/27/2006 13:00:00 8 1 9.5 6.1 8 1 9.9 6.1 8.2 1 10.7 6.1 156 8 145 165 6.8 0 7.3 6.7 09/27/2006 13:10:00 7.9 0.5 9.1 6.1 7.9 0.5 9.1 6.1 8.1 0.6 9.5 5.7 151 3 152 165 6.9 0 7.3 6.5 09/27/2006 13:20:00 8.2 0.5 9.5 7.2 8.2 0.5 9.5 7.2 8.1 0.6 9.5 6.5 150 3 151 165 7.1 0 7.3 6.2 09/27/2006 13:30:00 7.6 1 9.5 5.7 7.6 1 9.5 5.7 7.6 1 9.5 5.3 150 4 148 165 7 0.2 7.3 6.2 09/27/2006 13:40:00 6.8 0.4 8 5.7 6.8 0.4 8 5.7 6.9 0.4 8 5.7 148 4 159 165 6.9 0.2 7.3 6.2 09/27/2006 13:50:00 5.9 0.4 6.8 4.9 5.8 0.4 7.2 4.6 5.9 0.4 7.2 4.9 148 4 148 165 7.1 0.1 7.3 6.2 09/27/2006 14:00:00 7.7 0.5 8.8 6.1 7.7 0.5 8.8 6.1 7.7 0.5 8.8 5.7 145 5 135 165 7.2 0.1 7.5 6.7 09/27/2006 14:10:00 6.8 0.6 8 4.2 6.8 0.6 8 4.9 6.7 0.8 8.4 4.2 142 6 144 165 7.3 0.1 7.5 7 09/27/2006 14:20:00 6.1 0.6 7.6 4.6 6 0.6 7.6 4.6 6.1 0.5 7.6 4.9 142 5 124 165 7.2 0.1 7.5 6.7 09/27/2006 14:30:00 5 0.6 6.8 3.8 4.9 0.6 6.5 3.8 4.9 0.6 6.1 3.4 137 8 142 165 7.1 0 7.3 6.7 09/27/2006 14:40:00 5.2 0.9 7.2 3 5.2 0.8 7.2 3.4 5.1 0.8 7.6 3.4 123 10 122 165 7.1 0.1 7.5 6.7 09/27/2006 14:50:00 6.1 0.9 8.8 4.2 6.2 0.9 8.8 4.2 6 1 8.8 3.8 106 9 96 165 7.3 0 7.5 7 09/27/2006 15:00:00 7.6 1 9.9 5.3 7.8 1 10.7 5.3 7.3 1 9.9 4.9 107 7 94 165 7.5 0 7.8 7.3 09/27/2006 15:10:00 8.7 1.2 11.1 5.3 8.8 1.2 11.1 5.7 8.1 1.2 11.1 4.2 113 8 124 165 7.7 0 7.8 7.3 09/27/2006 15:20:00 9.4 0.9 11.8 7.2 9.5 0.9 12.2 6.8 8.9 1 11.8 6.1 116 7 111 165 7.9 0.1 8.3 7.3 09/27/2006 15:30:00 9.1 1 11.5 6.1 9.3 1 11.5 5.7 8.7 1 11.5 5.3 115 6 111 165 8 0 8.3 7.5 09/27/2006 15:40:00 8.7 1.2 11.5 4.2 8.8 1.2 11.8 4.2 8.2 1.3 11.5 4.6 109 7 111 165 8.1 0 8.3 7.8 09/27/2006 15:50:00 8.2 1 11.5 4.9 8.4 1 11.1 4.6 7.7 1.1 10.7 4.2 104 7 99 165 8.2 0 8.5 7.8 09/27/2006 16:00:00 8.2 1 10.7 5.7 8.4 1 11.1 5.7 7.7 1 10.3 4.9 97 7 92 165 8.3 0 8.5 8 09/27/2006 16:10:00 8.2 1.1 11.1 4.9 8.4 1.1 11.5 5.3 7.9 1.2 10.7 4.6 96 7 98 165 8.4 0 8.5 8 09/27/2006 16:20:00 8.6 1 11.8 5.7 8.8 1 12.2 5.7 8.2 1.1 10.7 4.9 94 8 102 165 8.5 0 8.5 8.3 09/27/2006 16:30:00 8.2 0.9 10.7 5.7 8.4 1 10.7 6.1 7.8 1 10.7 5.3 94 9 78 165 8.6 0 8.8 8.3 09/27/2006 16:40:00 8.1 1.4 11.1 4.2 8.3 1.5 11.5 4.6 7.8 1.3 11.1 4.2 103 9 105 165 8.8 0 9 8.5 09/27/2006 16:50:00 7.4 1.3 11.5 4.2 7.5 1.3 11.5 4.2 7.3 1.3 10.7 4.2 121 11 114 165 9 0 9 8.8 09/27/2006 17:00:00 8.1 1.6 11.5 4.2 8.2 1.5 11.5 4.2 7.7 1.5 11.1 4.6 129 11 136 165 9.1 0 9.3 8.8 09/27/2006 17:10:00 7.9 1 10.3 4.9 8 1 10.7 5.3 7.7 1 10.7 4.9 137 6 132 165 9.3 0 9.6 9 09/27/2006 17:20:00 6.3 0.9 8.8 4.2 6.3 0.9 8.4 4.2 6.3 0.9 8.4 4.2 140 6 135 165 9.4 0 9.6 8.8 09/27/2006 17:30:00 6 0.6 7.2 4.6 5.9 0.6 7.2 4.6 6 0.6 7.6 4.2 144 3 142 165 9.4 0.1 9.6 8.8 09/27/2006 17:40:00 4.8 0.3 5.7 3.8 4.6 0.3 5.3 3.8 4.9 0.3 5.7 4.2 148 4 146 165 9.4 0.3 9.8 9 09/27/2006 17:50:00 3.2 0.7 4.6 1.9 3 0.7 4.6 1.1 3.5 0.6 4.9 2.3 151 4 150 165 9.6 0.1 10.1 9 09/27/2006 18:00:00 1.6 0.6 2.6 0.4 1.1 0.7 2.6 0.4 2.2 0.5 3 1.1 156 8 155 165 9.7 0.1 9.8 9.3 09/27/2006 18:10:00 0.8 0.4 1.9 0.4 0.4 0.2 1.1 0.4 1.3 0.4 2.3 0.4 192 20 175 165 9.4 0.2 9.8 8.8 09/27/2006 18:20:00 1.3 0.7 2.6 0.4 1 0.7 3 0.4 1.5 0.5 2.6 0.4 280 17 261 165 9.4 0.2 9.6 9 09/27/2006 18:30:00 2 0.5 2.6 0.7 1.8 0.5 2.6 0.4 1.8 0.4 3 1.1 290 8 286 165 9.4 0.2 9.8 9 09/27/2006 18:40:00 1 0.6 2.3 0.4 0.8 0.5 2.3 0.4 1.6 0.6 3 0.4 241 33 287 165 9.4 0.1 9.8 8.8 09/27/2006 18:50:00 0.8 0.4 3 0.4 0.5 0.3 2.3 0.4 1.4 0.4 2.6 0.4 262 18 238 165 9.2 0.2 9.6 8.5 09/27/2006 19:00:00 1.4 0.7 3 0.4 1.2 0.6 2.6 0.4 1.7 0.5 2.6 0.4 296 15 297 165 9 0 9.3 8.8 09/27/2006 19:10:00 2 0.4 3 1.1 1.7 0.5 3 0.7 2.1 0.5 3.4 1.1 294 6 297 165 8.9 0 9.3 8.5 09/27/2006 19:20:00 1.4 0.4 2.3 0.4 1 0.5 2.3 0.4 2.2 0.4 3.4 1.1 248 21 290 165 8.8 0 9 8.5 09/27/2006 19:30:00 3 0.8 4.9 1.1 3 1.1 5.3 0.7 3.9 1 5.7 1.9 251 13 246 165 8.6 0.1 8.8 8.3 09/27/2006 19:40:00 6 0.8 7.6 3.4 6.3 0.7 8 3.8 6.3 0.6 8 4.6 278 6 284 165 8.5 0.1 8.8 8 09/27/2006 19:50:00 6.1 0.5 7.6 4.2 6.1 0.5 7.6 4.6 6 0.6 7.2 4.6 281 4 274 165 8.5 0 8.8 8.3 09/27/2006 20:00:00 5.2 1 7.2 3 5.2 1 7.2 3 5.2 0.9 7.2 2.6 284 5 284 165 8.5 0 8.8 8.3 09/27/2006 20:10:00 5.1 0.7 7.2 3.4 5.1 0.8 7.2 3.4 5 0.9 7.2 2.6 284 5 279 165 8.5 0 8.8 8.3 09/27/2006 20:20:00 4.3 1 7.6 2.3 4.3 1 7.6 1.9 3.9 1 6.5 1.9 293 8 293 165 8.5 0.1 8.8 8.3 09/27/2006 20:30:00 5.6 1.2 8 3 5.5 1.2 8 2.6 5 1.4 8.4 2.3 290 7 282 165 8.4 0.1 8.8 8 09/27/2006 20:40:00 4.9 0.5 6.1 3.8 4.8 0.5 6.1 3.8 4 0.7 5.7 2.6 292 5 289 165 8.3 0 8.5 7.8 09/27/2006 20:50:00 4.4 0.6 5.7 3 4.3 0.7 5.7 2.6 3.4 0.5 4.9 2.3 297 5 297 165 8.3 0 8.5 7.8 09/27/2006 21:00:00 4.3 0.5 5.7 2.6 4.2 0.5 5.3 2.3 3.4 0.5 4.6 2.3 298 6 303 165 8.1 0.1 8.3 7.5 09/27/2006 21:10:00 5.4 0.8 7.2 3.8 5.4 0.8 7.2 3.8 4.1 0.8 6.1 2.3 295 4 291 165 8 0.1 8.3 7.5 09/27/2006 21:20:00 6.1 0.4 7.2 4.9 6.1 0.4 7.2 4.9 5.4 0.6 7.2 3.8 289 4 286 165 8 0.1 8.3 7.5 09/27/2006 21:30:00 6.1 0.5 7.2 4.6 6.2 0.6 7.2 4.6 5.5 1 7.2 3 284 6 284 165 8 0.1 8.3 7.5 09/27/2006 21:40:00 4.9 0.5 6.1 3.8 4.9 0.5 6.1 3.4 4.6 0.7 6.1 2.6 286 4 292 165 7.9 0.1 8 7.5 09/27/2006 21:50:00 5.1 0.4 6.5 4.2 5.1 0.4 6.5 4.2 4.8 0.5 6.1 3.4 288 3 282 165 7.8 0.1 8 7.3 09/27/2006 22:00:00 4.9 0.4 5.7 3.8 4.9 0.4 5.7 3.8 4.7 0.5 6.1 3 288 4 289 165 7.8 0 8.3 7.3 09/27/2006 22:10:00 4.1 0.5 5.3 2.6 4.1 0.5 5.7 2.6 3.5 0.6 4.9 1.5 291 6 288 165 7.9 0 8 7.3 09/27/2006 22:20:00 4.4 0.4 5.3 3 4.3 0.4 5.7 3 3.6 0.6 5.3 1.9 292 6 290 165 7.8 0 8 7.5 09/27/2006 22:30:00 3.8 0.7 5.3 2.3 3.7 0.7 4.9 1.9 3.1 0.7 4.9 1.5 295 9 288 165 7.6 0.1 8 7.3 09/27/2006 22:40:00 4.4 0.4 5.3 3.4 4.4 0.4 5.7 3 4.2 0.5 5.7 2.6 283 5 280 165 7.6 0 7.8 7.3 09/27/2006 22:50:00 4.2 0.6 5.7 2.6 4.2 0.7 5.7 2.6 3.6 1 5.7 1.9 291 5 283 165 7.7 0 7.8 7.5 09/27/2006 23:00:00 4 0.4 5.3 3 4 0.4 5.3 3 3.7 0.6 5.3 2.3 290 4 287 165 7.8 0 8 7.5 09/27/2006 23:10:00 4.1 0.4 4.9 3 4.1 0.4 4.9 3 4 0.5 5.3 2.3 288 4 287 165 7.9 0 8 7.5 09/27/2006 23:20:00 4.2 0.5 5.3 2.6 4.2 0.5 5.3 2.6 4.3 0.6 5.7 2.6 285 4 290 165 7.8 0 8 7.5 09/27/2006 23:30:00 3.5 0.3 4.2 2.6 3.5 0.3 4.2 2.6 3.7 0.3 4.6 3 280 4 281 165 7.8 0 8 7.5 09/27/2006 23:40:00 3.5 0.4 4.6 1.9 3.4 0.4 4.2 2.3 3.7 0.4 4.6 2.3 279 5 277 165 7.8 0 8 7.5 09/27/2006 23:50:00 3.2 0.4 4.2 2.3 3.1 0.5 4.2 1.9 3.4 0.5 4.6 2.3 279 5 273 165 8 0 8.3 7.8 09/28/2006 00:00:00 2.4 0.5 3.4 1.1 2.3 0.5 3.4 1.1 2.8 0.4 3.8 1.9 272 8 275 165 8 0.1 8.3 7.5 09/28/2006 00:10:00 1.6 0.6 3.4 0.4 1.5 0.6 3.4 0.4 2.3 0.4 3.4 1.1 256 9 245 165 8.1 0 8.5 8 09/28/2006 00:20:00 2.3 0.4 3.4 1.5 2.3 0.4 3.4 1.5 2.7 0.4 4.2 1.5 276 12 279 165 8.3 0 8.5 8 09/28/2006 00:30:00 2.4 0.3 3 1.5 2.2 0.4 3 1.1 2.2 0.4 3.4 1.1 292 4 295 165 8.3 0 8.5 8.3 09/28/2006 00:40:00 2.3 0.4 3.4 1.5 2.2 0.4 3 1.1 2.6 0.3 3.4 1.9 279 9 278 165 8.1 0 8.3 8 09/28/2006 00:50:00 2.2 0.4 3 1.1 2 0.4 3 0.7 2.5 0.3 3.4 1.9 271 6 272 165 8.3 0 8.5 8 09/28/2006 01:00:00 2.3 0.3 3 1.1 2.2 0.4 3 1.1 2.6 0.3 3.4 1.9 279 3 279 165 8.2 0 8.5 8 09/28/2006 01:10:00 2.5 0.3 3.8 1.9 2.4 0.4 3.8 1.5 2.8 0.3 3.4 1.9 279 5 285 165 8.1 0 8.5 8 09/28/2006 01:20:00 2 0.3 2.6 1.5 1.8 0.3 2.6 1.1 2.3 0.3 3 1.5 276 9 271 165 8.2 0 8.5 8 09/28/2006 01:30:00 1.3 0.5 2.3 0.4 1 0.6 2.3 0.4 1.8 0.4 2.6 0.7 248 23 269 165 8.3 0.1 8.5 8 09/28/2006 01:40:00 1.3 0.5 2.6 0.4 1.1 0.6 2.6 0.4 1.6 0.5 2.6 0.4 246 19 257 165 7.9 0 8.3 7.8 09/28/2006 01:50:00 2.1 0.7 3.4 0.4 1.9 0.7 3.4 0.4 2.5 0.5 3.4 1.5 277 8 282 165 8.1 0 8.5 8 09/28/2006 02:00:00 2.1 0.3 3 1.1 2 0.4 3 1.1 2.1 0.4 3 1.1 297 9 305 165 8.1 0.2 8.5 7.8 09/28/2006 02:10:00 2.8 0.4 4.2 1.9 2.7 0.5 4.2 1.9 2.7 0.3 3.4 1.9 310 5 303 165 7.6 0.2 8 7 09/28/2006 02:20:00 2.7 0.4 3.8 1.9 2.6 0.4 3.4 1.9 2.5 0.3 3.4 1.5 308 3 309 165 7.3 0 7.5 7 09/28/2006 02:30:00 2 0.4 3 1.1 1.9 0.5 3 0.7 1.9 0.5 3 0.7 300 6 310 165 8.1 0.3 8.5 7.5 09/28/2006 02:40:00 1 0.5 2.3 0.4 0.8 0.4 1.9 0.4 1.4 0.4 2.3 0.4 303 76 143 165 8.6 0 8.8 8.3 09/28/2006 02:50:00 0.7 0.5 2.3 0.4 0.5 0.4 2.3 0.4 1.2 0.6 2.3 0.4 184 27 143 165 8 0.2 8.5 7.5 09/28/2006 03:00:00 2.2 0.5 3 1.1 2 0.5 3 0.4 2.4 0.3 3 1.5 143 5 146 165 7.6 0.2 8 7 09/28/2006 03:10:00 1 0.4 1.9 0.4 0.6 0.4 1.5 0.4 1.7 0.3 2.3 0.7 135 6 137 165 7.7 0 7.8 7.3 09/28/2006 03:20:00 0.7 0.3 1.5 0.4 0.4 0 0.4 0.4 1 0.4 1.9 0.4 149 13 160 165 8 0.1 8.3 7.5 09/28/2006 03:30:00 1.3 0.6 2.6 0.4 0.8 0.6 2.3 0.4 1.5 0.5 2.6 0.4 159 7 163 165 8 0 8.3 7.5 09/28/2006 03:40:00 1.9 0.5 3 0.7 1.5 0.6 3 0.4 2 0.4 3 1.1 158 9 156 165 8.2 0 8.5 7.8 09/28/2006 03:50:00 0.4 0.1 1.1 0.4 0.4 0 0.4 0.4 0.5 0.3 1.5 0.4 166 0 166 165 8.3 0.1 8.5 7.8 09/28/2006 04:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.7 0.4 166 0 165 165 7.8 0 8.5 7.3 09/28/2006 04:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 166 0 165 165 7.8 0.1 8.3 7.3 09/28/2006 04:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.5 0.3 1.5 0.4 166 0 165 165 8.1 0 8.3 7.5 09/28/2006 04:30:00 0.4 0.2 1.1 0.4 0.4 0 0.4 0.4 0.9 0.5 1.9 0.4 219 102 12 165 8.1 0 8.3 8 09/28/2006 04:40:00 0.4 0.2 1.5 0.4 0.4 0 0.7 0.4 0.6 0.3 1.5 0.4 98 33 114 165 8.4 0.1 8.5 8.3 09/28/2006 04:50:00 0.8 0.3 1.5 0.4 0.4 0.2 1.5 0.4 1.2 0.4 1.9 0.4 127 27 110 165 8.4 0 8.5 8.3 09/28/2006 05:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.6 0.3 1.1 0.4 138 0 165 165 8.3 0 8.5 8 09/28/2006 05:10:00 0.4 0.1 1.1 0.4 0.4 0 0.4 0.4 0.4 0.1 0.7 0.4 171 7 173 165 8.3 0 8.5 8 09/28/2006 05:20:00 0.6 0.3 1.5 0.4 0.4 0.1 1.1 0.4 0.9 0.6 1.9 0.4 173 0 173 165 8 0 8.3 7.8 09/28/2006 05:30:00 1.2 0.5 2.3 0.4 0.7 0.5 1.9 0.4 1.8 0.5 3 1.1 344 47 340 165 7.8 0 8 7.5 09/28/2006 05:40:00 2 0.3 2.6 1.1 1 0.4 2.3 0.4 2.4 0.3 3 1.9 0 10 353 165 7.5 0 7.8 7.5 09/28/2006 05:50:00 1.1 0.6 1.9 0.4 0.5 0.3 1.5 0.4 1.3 0.6 2.3 0.4 17 4 23 165 7.8 0 8.3 7.5 09/28/2006 06:00:00 1.1 0.6 2.3 0.4 0.7 0.4 1.9 0.4 1.2 0.7 2.3 0.4 94 49 142 165 8.1 0.1 8.5 7.8 09/28/2006 06:10:00 0.6 0.4 1.9 0.4 0.4 0.1 1.1 0.4 0.8 0.4 1.9 0.4 128 9 142 165 7.9 0 8.3 7.8 09/28/2006 06:20:00 0.6 0.4 2.3 0.4 0.4 0.2 1.9 0.4 0.9 0.7 2.6 0.4 87 36 54 165 8 0 8.3 7.8 09/28/2006 06:30:00 1.8 0.4 2.6 0.7 1.3 0.5 2.3 0.4 2.3 0.3 3 1.5 43 12 63 165 7.8 0 8 7.5 09/28/2006 06:40:00 1.8 0.5 2.6 0.4 1.4 0.7 2.6 0.4 2.4 0.4 3 1.5 45 6 50 165 7.9 0.1 8 7.5 09/28/2006 06:50:00 0.6 0.4 1.5 0.4 0.4 0.1 1.5 0.4 0.9 0.5 1.9 0.4 110 32 63 165 8 0 8.3 7.5 09/28/2006 07:00:00 2.2 0.7 3 0.4 1.9 0.8 3 0.4 2.5 0.8 3.4 0.4 30 26 25 165 8 0.1 8.3 7.5 09/28/2006 07:10:00 2.8 0.2 3.4 2.3 2.7 0.2 3 2.3 3.2 0.2 3.4 2.6 29 5 29 165 8 0 8.3 7.5 09/28/2006 07:20:00 2.6 0.2 3 2.3 2.5 0.3 3 1.9 2.9 0.2 3.4 2.6 42 5 39 165 8.2 0 8.3 7.8 09/28/2006 07:30:00 2.8 0.3 3.4 1.9 2.6 0.3 3.4 1.5 3.2 0.3 3.8 2.3 61 5 53 165 8.1 0 8.3 8 09/28/2006 07:40:00 3.2 0.3 3.8 2.3 3.1 0.3 3.8 2.3 3.4 0.2 4.2 3 48 8 47 165 8.1 0 8.3 7.8 09/28/2006 07:50:00 3.4 0.2 3.8 3 3.3 0.2 3.8 2.6 3.6 0.2 4.2 3 46 6 39 165 8 0 8.3 7.8 09/28/2006 08:00:00 3.3 0.3 3.8 2.3 3.3 0.4 3.8 2.3 3.6 0.3 4.2 3 55 4 54 165 8 0 8.5 7.8 09/28/2006 08:10:00 3.7 0.2 4.2 3 3.6 0.2 4.2 3 3.6 0.3 4.6 2.6 37 9 52 165 7.9 0 8.3 7.5 09/28/2006 08:20:00 3.6 0.3 4.2 3 3.3 0.5 4.2 1.9 3.7 0.3 4.2 3 22 3 22 165 7.8 0 8 7.5 09/28/2006 08:30:00 3.8 0.4 4.6 3 3.2 0.5 4.2 1.5 3.8 0.4 4.6 3 18 1 18 165 7.6 0 7.8 7.5 09/28/2006 08:40:00 4.4 0.2 4.9 3.8 3.9 0.4 4.6 1.9 4.7 0.2 5.7 4.2 18 2 19 165 7.7 0 7.8 7.5 09/28/2006 08:50:00 4 0.2 4.6 3.4 3.6 0.3 4.6 2.6 4.5 0.2 4.9 3.8 21 3 19 165 7.8 0 8 7.5 09/28/2006 09:00:00 3.8 0.2 4.6 3 3.2 0.5 4.2 1.9 4.3 0.2 4.9 3.8 19 4 19 165 8 0 8 7.8 09/28/2006 09:10:00 3.3 0.3 4.2 2.6 2 0.7 3.4 0.7 4 0.3 4.6 3 10 5 10 165 7.9 0 8 7.8 09/28/2006 09:20:00 2.9 0.3 3.4 2.3 1.4 0.6 3 0.4 3.2 0.3 3.8 2.6 359 7 11 165 8 0 8.3 7.8 09/28/2006 09:30:00 2.7 0.3 3.4 1.9 1.9 0.7 3 0.4 2.9 0.3 3.4 2.3 351 6 349 165 8 0 8.3 7.8 09/28/2006 09:40:00 2.6 0.2 3 2.3 2.3 0.2 3 1.9 2.8 0.2 3.4 2.3 334 7 347 165 8.1 0 8.5 7.5 09/28/2006 09:50:00 2.3 0.3 3 1.9 1.9 0.3 2.6 1.1 2.4 0.3 3 1.9 337 8 325 165 8.2 0 8.5 7.5 09/28/2006 10:00:00 2.5 0.3 3 1.5 1.9 0.4 2.6 1.1 2.5 0.2 3 1.9 344 7 346 165 8.3 0 8.8 7.5 09/28/2006 10:10:00 2.8 0.4 3.8 1.9 2.1 0.5 3.4 1.1 2.7 0.3 3.8 2.3 348 5 353 165 8.6 0 8.8 8.3 09/28/2006 10:20:00 3.3 0.5 4.6 2.3 2.3 0.8 4.2 0.7 3.4 0.4 4.2 2.3 351 7 344 165 8.9 0 9 8.5 09/28/2006 10:30:00 3.8 0.6 4.9 2.3 2.8 0.9 4.9 0.7 3.8 0.5 5.3 2.6 353 7 353 165 9 0 9.3 8.5 09/28/2006 10:40:00 4.5 0.5 5.7 3 4 0.7 5.3 1.5 4.4 0.6 5.7 3 348 5 350 165 9.1 0 9.3 9 09/28/2006 10:50:00 4.9 0.4 5.7 3.8 4.3 0.7 5.7 2.3 5 0.4 5.7 3.8 349 4 348 165 9.2 0 9.3 9 09/28/2006 11:00:00 5.5 0.5 6.5 4.2 4.8 1 6.5 1.9 5.4 0.5 6.1 4.2 351 5 347 165 9.4 0.1 9.6 8.8 09/28/2006 11:10:00 5.7 0.5 6.8 4.6 4.5 1 6.8 2.3 5.8 0.5 6.8 4.6 353 3 351 165 9.3 0.3 9.6 8.8 09/28/2006 11:20:00 6.2 0.5 7.2 4.9 4.8 1.1 7.2 2.3 6.2 0.5 7.2 4.6 354 4 354 165 9.4 0.3 9.6 8.8 09/28/2006 11:30:00 6.8 0.4 8 5.7 6.4 0.6 7.6 3.8 6.9 0.4 8 6.1 350 3 350 165 9.2 0.2 9.6 8.8 09/28/2006 11:40:00 5.8 0.6 7.2 4.2 4.4 1 6.8 2.3 6 0.5 7.2 4.6 355 7 357 165 9 0 9.3 8.8 09/28/2006 11:50:00 6.1 0.7 7.6 4.6 4.7 1.4 7.6 2.3 6.3 0.7 8 4.9 354 6 348 165 9 0 9 8.8 09/28/2006 12:00:00 5.1 0.4 6.1 4.2 3.2 0.6 5.3 1.9 5.3 0.4 6.1 4.6 5 6 353 165 9 0 9.3 8.5 09/28/2006 12:10:00 5 0.7 6.8 2.6 3.4 0.9 5.7 1.5 5.1 0.6 6.8 3.4 360 9 3 165 9.3 0.1 9.6 8.8 09/28/2006 12:20:00 5.3 0.7 7.2 3.8 4.1 1.3 6.8 1.9 5.3 0.6 6.8 3.8 352 10 360 165 9.4 0.3 9.8 9 09/28/2006 12:30:00 5 0.6 7.2 3.8 4.1 1.1 6.5 1.9 4.9 0.6 6.8 3.4 353 11 360 165 9.7 0.2 10.1 9 09/28/2006 12:40:00 5.1 0.8 6.8 3.4 4.4 1.2 6.8 1.5 4.9 0.7 6.8 3.4 348 10 340 165 10 0.2 10.6 9.6 09/28/2006 12:50:00 4.4 1 6.8 2.3 3.8 1.2 6.8 1.1 4.3 1 6.5 1.9 346 13 347 165 10.5 0.1 10.9 10.3 09/28/2006 13:00:00 5.4 0.8 8 3 4.5 1 6.8 2.3 5.2 0.9 8 2.6 353 11 10 165 10.5 0 10.9 10.3 09/28/2006 13:10:00 6.6 1.1 9.5 3.4 5.8 1.2 9.5 2.6 6.2 1 9.1 4.6 350 11 355 165 10.1 0.1 10.6 9.8 09/28/2006 13:20:00 5.7 1.5 9.1 1.9 4.8 1.4 8.4 1.5 5.4 1.3 8 2.6 354 17 5 165 9.9 0 10.1 9.6 09/28/2006 13:30:00 4.8 1.7 8 0.7 4 1.6 7.6 0.4 4.1 1.5 6.8 0.4 3 18 9 165 9.9 0 10.3 9.3 09/28/2006 13:40:00 4.8 1.1 7.2 2.3 4.3 1.2 7.6 1.5 4.1 1.1 6.8 1.5 347 14 350 165 9.9 0.1 10.3 9.3 09/28/2006 13:50:00 5.7 1.4 8.8 2.3 5 1.5 8.4 1.5 5.2 1.3 8 2.3 348 13 341 165 10.1 0 10.3 9.8 09/28/2006 14:00:00 7.1 1.3 10.7 3.4 6.5 1.3 11.1 3 6.6 1.3 9.9 3 345 11 347 165 10.1 0.1 10.3 9.8 09/28/2006 14:10:00 6.8 1.7 10.7 3.8 6.3 1.9 11.1 1.9 6.2 1.7 10.7 3 344 11 354 165 10.3 0 10.6 9.8 09/28/2006 14:20:00 6.6 1.2 9.9 3.4 6.4 1.3 9.9 2.6 6 1.3 8.8 3 335 12 337 165 10.6 0 10.9 10.3 09/28/2006 14:30:00 8 1.6 14.1 4.2 7.8 1.6 14.5 4.2 7.6 1.5 12.6 4.2 339 9 346 165 10.4 0 10.6 10.3 09/28/2006 14:40:00 6.7 0.8 9.1 4.6 6.2 1 8.4 3.4 6.2 0.9 9.5 4.2 345 10 2 165 10.3 0 10.6 9.8 09/28/2006 14:50:00 8.1 1.7 11.8 4.2 7.3 2.1 11.8 2.6 7.4 2 11.8 3 350 9 349 165 10.4 0 10.6 10.1 09/28/2006 15:00:00 7.3 1.4 11.5 4.2 6.8 1.5 10.7 3.4 6.9 1.3 11.5 3.4 343 12 350 165 10.5 0 10.9 9.8 09/28/2006 15:10:00 9.1 2.6 14.1 2.6 8.6 2.5 14.5 2.3 8.6 2.6 13.7 2.6 345 12 351 165 10.5 0 10.9 9.8 09/28/2006 15:20:00 11.1 2 15.6 5.3 10.1 2 14.5 5.3 10.4 2 14.9 4.9 346 13 358 165 10.3 0 10.6 9.8 09/28/2006 15:30:00 12.5 1.9 17.9 7.2 11.6 2.2 17.2 5.7 11.7 2.2 16.4 5.7 347 9 349 165 10.1 0 10.3 9.8 09/28/2006 15:40:00 13.5 1.5 19.1 9.9 13 1.9 19.5 7.2 13.3 1.5 17.6 9.5 344 9 349 165 10.1 0 10.3 9.6 09/28/2006 15:50:00 13.3 1.6 16.8 8.8 12.8 1.9 16.4 5.7 12.8 1.7 16.4 8.4 343 10 336 165 10 0 10.3 9.8 09/28/2006 16:00:00 10.7 1.9 15.6 6.8 10.3 2 16.1 6.1 9.8 1.8 15.3 6.1 336 15 344 165 10.1 0 10.3 9.8 09/28/2006 16:10:00 11.9 1.5 15.6 8 11.4 1.7 15.3 6.5 11.7 1.6 16.1 8 341 11 342 165 10.1 0 10.3 9.8 09/28/2006 16:20:00 9.7 1.5 14.1 6.8 9.6 1.7 14.5 4.6 9.3 1.5 13.3 6.1 336 13 333 165 9.9 0 10.1 9.8 09/28/2006 16:30:00 8.6 1.2 11.8 6.1 8.1 1.5 11.8 3.4 8.4 1.2 12.6 4.9 337 16 319 165 9.8 0 10.1 9.6 09/28/2006 16:40:00 7.4 1.2 11.1 5.3 7.2 1.2 11.1 4.6 7.2 1 10.3 4.9 333 13 318 165 9.6 0 9.8 9.6 09/28/2006 16:50:00 7 1 11.1 4.2 6.8 1 11.1 3.8 6.6 1.1 10.3 3.4 336 13 344 165 9.6 0 9.8 9.3 09/28/2006 17:00:00 7.3 1.2 11.8 4.6 6.4 1.3 9.9 3 7.2 1.1 11.5 3.8 351 12 0 165 9.5 0 9.6 9.3 09/28/2006 17:10:00 7.8 1.9 12.6 3.8 7 1.7 12.2 3.8 7 1.7 12.2 3.4 340 22 334 165 9.4 0 9.6 9 09/28/2006 17:20:00 10.5 1.3 14.5 7.2 10.1 1.4 14.1 4.6 10.2 1.4 13.3 6.8 344 9 341 165 9.2 0 9.6 9 09/28/2006 17:30:00 10.9 1.8 16.4 7.2 10.2 1.6 15.3 6.1 10.7 1.9 16.8 6.1 341 12 358 165 9.2 0 9.6 9 09/28/2006 17:40:00 11.1 1.3 15.3 8 10.6 1.8 15.3 5.3 11.1 1.3 14.9 8.4 343 9 343 165 9 0.1 9.6 8.5 09/28/2006 17:50:00 9.6 1.2 13.3 6.8 9.3 1.2 13 5.3 9.4 1.1 13.3 6.8 341 10 341 165 8.9 0.2 9.3 8.5 09/28/2006 18:00:00 8 1.3 11.5 5.7 7.8 1.1 11.8 5.7 8 1.3 11.5 5.7 338 11 357 165 8.9 0.2 9.3 8.5 09/28/2006 18:10:00 6.7 0.9 9.1 5.3 6.9 0.8 9.1 5.3 6.2 0.8 8 3.4 314 9 305 165 8.7 0.2 9 8.3 09/28/2006 18:20:00 7.6 0.8 9.5 5.3 7.6 0.7 9.5 6.1 6.4 0.8 8.8 4.6 307 6 300 165 8.6 0.1 8.8 8 09/28/2006 18:30:00 8.4 1.1 11.1 6.1 8.3 1.1 11.1 5.7 7.2 1.1 10.7 4.6 311 8 306 165 8.5 0 8.8 8 09/28/2006 18:40:00 7.7 1 9.9 4.9 7.7 1 9.5 4.9 7.2 1 9.5 4.6 318 13 308 165 8.4 0 8.5 8 09/28/2006 18:50:00 7.3 0.9 10.3 4.9 7.3 0.8 9.9 5.3 7.2 0.9 9.5 4.9 330 10 322 165 8.3 0 8.5 8 09/28/2006 19:00:00 9.4 1.5 14.1 6.8 9.1 1.5 15.6 5.7 9.1 1.5 13.7 5.3 338 12 348 165 8.2 0 8.5 8 09/28/2006 19:10:00 7.9 1.1 11.5 4.9 7.8 1.1 10.7 5.3 7.5 1 10.3 5.3 332 9 326 165 8.1 0 8.3 7.8 09/28/2006 19:20:00 7.4 1.2 11.5 4.6 7.3 1.2 11.1 4.2 6.2 1 9.5 2.6 313 14 304 165 8.1 0 8.5 7.8 09/28/2006 19:30:00 10.1 1.2 13.3 6.5 10 1.2 13.3 6.8 8.4 1.3 12.2 4.9 308 8 293 165 8 0.1 8.3 7.5 09/28/2006 19:40:00 10.7 1.5 15.6 7.6 10.6 1.4 15.3 7.6 9.2 1.1 12.6 5.3 309 9 307 165 8 0.1 8.3 7.3 09/28/2006 19:50:00 12.2 1.5 16.8 8.8 12 1.4 16.4 8.4 10.1 1.5 15.3 6.5 308 6 300 165 7.9 0.1 8.3 7.3 09/28/2006 20:00:00 10.9 1.5 16.4 6.5 10.8 1.5 16.4 6.1 9.6 1.6 14.9 5.7 311 10 308 165 8 0.1 8.3 7.5 09/28/2006 20:10:00 11 1.1 14.1 7.6 10.8 1.1 13.7 7.6 9.1 1.3 11.8 5.3 306 6 303 165 7.7 0 8 7 09/28/2006 20:20:00 9.2 1.5 13 4.6 9.1 1.5 13 5.3 8.2 1.5 12.2 3.8 315 12 300 165 7.6 0.1 8 7 09/28/2006 20:30:00 7.4 1.1 10.3 4.6 7.4 1.1 10.7 4.2 6.6 1.1 9.5 3.8 312 11 286 165 7.8 0.2 8 7.3 09/28/2006 20:40:00 5.8 1.2 9.1 2.3 5.8 1.2 9.5 2.3 5 1.3 9.1 1.9 313 11 317 165 7.8 0.2 8.3 7.3 09/28/2006 20:50:00 5.3 0.9 7.2 2.3 5.2 0.9 6.8 2.6 4.9 1 7.6 2.3 320 15 325 165 7.8 0.2 8 7.3 09/28/2006 21:00:00 5.9 1.2 9.9 3.4 5.8 1.2 9.9 3.4 5.2 0.9 8.4 2.6 310 12 303 165 7.6 0.2 7.8 7 09/28/2006 21:10:00 10.9 1.5 13 6.8 10.7 1.5 13 6.8 9.7 1.7 13 5.3 311 6 307 165 7.4 0.2 7.8 6.7 09/28/2006 21:20:00 9.5 1 12.2 7.2 9.4 1 11.8 7.2 8.8 1.3 12.6 5.3 315 7 321 165 7.3 0 7.5 7 09/28/2006 21:30:00 11.1 1.7 15.6 6.8 10.9 1.7 15.3 6.8 10 1.7 14.9 6.5 315 6 307 165 7.3 0 7.5 7 09/28/2006 21:40:00 13.3 1.5 16.4 6.5 13.1 1.5 16.4 6.8 12.4 1.7 16.4 7.2 316 9 302 165 7.4 0 7.5 7.3 09/28/2006 21:50:00 12.7 1.4 16.8 9.1 12.6 1.3 16.8 9.1 11.6 1.4 15.6 8.4 315 9 312 165 7.4 0.1 7.8 7 09/28/2006 22:00:00 10.3 2.1 14.9 4.2 10.2 2 14.9 4.6 9 2 14.1 4.2 314 11 310 165 7.3 0 7.8 7.3 09/28/2006 22:10:00 8.8 2.3 13.7 4.2 8.8 2.1 13.7 4.6 7.7 2.1 13 3.4 319 13 334 165 7.3 0 7.5 7 09/28/2006 22:20:00 10.4 1.4 13.7 5.3 10.3 1.4 14.1 5.3 9.4 1.6 13.3 4.6 322 12 307 165 7.3 0 7.5 7 09/28/2006 22:30:00 8.3 1.2 11.8 5.3 8.3 1.2 11.5 5.7 7.3 1.2 10.7 3.8 317 10 307 165 7.3 0 7.5 7 09/28/2006 22:40:00 10.1 1.7 13.7 5.3 10 1.7 13.7 5.3 9.2 1.7 13 4.9 317 10 310 165 7.1 0 7.3 7 09/28/2006 22:50:00 12.3 2.2 16.8 6.5 12.1 2.1 16.1 6.5 11.6 2.4 17.2 6.5 320 9 326 165 6.9 0 7 6.7 09/28/2006 23:00:00 12.9 1.5 16.4 6.8 12.7 1.4 16.4 7.2 11.8 1.2 14.9 8 316 7 307 165 6.6 0 6.7 6.2 09/28/2006 23:10:00 12.2 1.3 16.4 7.6 12 1.3 16.8 8 11.4 1.4 15.3 7.6 318 8 314 165 6.4 0.1 6.7 6.2 09/28/2006 23:20:00 12.7 1.7 16.8 8.4 12.6 1.7 16.4 8.8 12 1.7 16.4 7.6 320 10 319 165 6.2 0 6.2 6 09/28/2006 23:30:00 12.5 1.6 16.4 8.8 12.3 1.5 16.1 8.8 12 1.6 15.6 8 321 7 316 165 6.2 0 6.2 6 09/28/2006 23:40:00 12.1 1.3 15.3 8.8 11.9 1.2 14.9 8.8 11.3 1.3 14.9 6.8 321 7 328 165 6.3 0 6.5 6 09/28/2006 23:50:00 12.5 1.3 16.1 9.1 12.3 1.3 15.6 8.8 11.9 1.4 15.6 8.8 320 9 334 165 6.2 0 6.7 6 09/29/2006 00:00:00 13.8 1.3 18.3 10.3 13.6 1.2 17.6 10.3 13.4 1.5 17.6 10.3 324 7 325 165 6.1 0 6.2 5.7 09/29/2006 00:10:00 13.2 1.5 16.1 8.8 13 1.5 16.1 8.8 12.8 1.9 16.8 8 317 6 322 165 6.1 0 6.2 6 09/29/2006 00:20:00 11.6 1.4 14.9 8.4 11.5 1.4 15.3 8.8 10.7 1.3 14.1 7.6 314 8 309 165 6.1 0 6.2 6 09/29/2006 00:30:00 10.2 1.2 13.7 6.5 10.2 1.2 13.7 7.2 9.4 1.4 13.3 6.1 310 8 312 165 6.2 0 6.5 6 09/29/2006 00:40:00 9 1.2 11.5 6.1 9 1.2 11.5 6.1 7.7 1.3 10.7 4.9 300 11 304 165 6.4 0 6.7 6.2 09/29/2006 00:50:00 8.1 1.3 11.1 4.6 8.2 1.3 11.8 4.9 7.3 1.5 11.1 3.4 292 9 280 165 6.2 0.1 6.5 5.7 09/29/2006 01:00:00 6.7 1.5 10.7 2.6 6.8 1.5 10.7 3 6 1.2 10.3 3.8 303 12 289 165 6.1 0.1 6.2 5.5 09/29/2006 01:10:00 3.9 1.7 9.1 0.7 3.9 1.7 9.1 0.4 3.6 1.3 8 0.7 298 18 295 165 5.9 0.2 6.2 5.2 09/29/2006 01:20:00 7.5 1.2 10.7 4.6 7.5 1.2 10.3 4.6 6.5 1.2 9.9 3.4 310 10 309 165 5.9 0 6.2 5.5 09/29/2006 01:30:00 7.9 1.2 10.7 4.2 7.9 1.1 11.1 4.6 6.8 1.1 9.9 4.2 307 7 315 165 6 0 6.2 5.5 09/29/2006 01:40:00 8 1.6 12.6 4.9 8 1.5 12.2 4.9 7 1.3 10.7 4.2 304 10 294 165 6.1 0 6.2 5.5 09/29/2006 01:50:00 9.4 1.3 13 6.8 9.4 1.3 13 6.8 7.6 1.3 11.1 4.6 302 8 303 165 6.1 0 6.2 5.5 09/29/2006 02:00:00 10 1.5 13 4.6 10 1.5 13 4.9 8.4 1.1 11.5 4.9 305 7 303 165 6.2 0 6.2 5.5 09/29/2006 02:10:00 10.9 1 13.7 8.4 10.8 1 13.7 8 8.8 1.3 13.7 5.7 303 7 305 165 6.1 0 6.2 5.5 09/29/2006 02:20:00 9.7 1.2 13.7 6.8 9.7 1.2 13.3 6.8 8.5 1.2 12.2 5.3 307 9 307 165 6 0.1 6.2 5.2 09/29/2006 02:30:00 10.7 1.1 13.7 7.6 10.6 1.1 13.3 7.6 9.2 1.2 13 5.7 308 7 303 165 5.9 0 6.2 5.5 09/29/2006 02:40:00 11.2 1.2 14.5 7.6 11.2 1.2 14.5 7.6 9.3 1.2 12.6 6.5 305 8 291 165 6.1 0 6.5 5.7 09/29/2006 02:50:00 11.1 1.1 14.5 8 11 1.2 14.5 8.4 9.8 1.3 13 6.8 307 7 301 165 6.1 0 6.2 5.5 09/29/2006 03:00:00 10.8 1 13.3 8.4 10.8 1 13.3 8.4 8.5 1.2 12.6 6.1 300 7 293 165 6.1 0 6.2 5.5 09/29/2006 03:10:00 12.3 1.4 16.4 8.8 12.3 1.5 16.4 8.8 9.2 1.2 12.6 6.8 299 6 292 165 6.2 0 6.2 6 09/29/2006 03:20:00 13.6 1.2 16.4 10.7 13.6 1.2 16.4 10.7 10.5 1.5 15.6 7.2 296 6 282 165 6.3 0 6.7 6.2 09/29/2006 03:30:00 12.2 1.2 15.3 9.5 12.2 1.2 15.3 9.5 9.5 1.5 14.9 6.5 296 6 289 165 6.4 0 6.7 6 09/29/2006 03:40:00 13.8 1.6 17.9 10.3 13.9 1.7 17.9 10.3 11.1 2 17.2 7.6 294 5 284 165 6.4 0 6.7 6.2 09/29/2006 03:50:00 14.2 1.4 17.2 10.7 14.2 1.5 17.6 10.7 11.1 1.7 17.2 8 297 7 286 165 6.4 0 6.7 6.2 09/29/2006 04:00:00 12.7 1 16.1 9.1 12.7 1 15.6 9.9 9.8 1.3 13.7 6.8 296 6 296 165 6.4 0 6.7 6.2 09/29/2006 04:10:00 12.1 2 17.2 8 12.2 1.9 16.8 7.6 10.4 2.1 16.1 5.7 292 8 287 165 6.5 0.1 6.7 6.2 09/29/2006 04:20:00 13.5 1.8 17.9 9.1 13.5 1.9 18.7 9.1 11 2.4 17.6 6.8 294 7 280 165 6.6 0 6.7 6.2 09/29/2006 04:30:00 15 1.5 19.5 11.5 15 1.6 18.7 10.7 11.5 1.7 17.2 7.2 296 6 302 165 6.6 0 7 6.2 09/29/2006 04:40:00 16 1.7 20.2 11.8 16 1.7 20.2 11.5 12.4 1.7 17.6 8.4 298 6 283 165 6.6 0 6.7 6.5 09/29/2006 04:50:00 17.7 1.5 21 13.7 17.7 1.5 21 14.1 13.8 1.7 19.1 9.9 295 6 294 165 6.7 0 7 6.7 09/29/2006 05:00:00 17.9 1.5 22.1 13.3 17.9 1.5 22.6 13.3 13.5 1.6 19.1 9.5 300 6 306 165 6.7 0 7 6.7 09/29/2006 05:10:00 17.7 1.5 21.8 13.7 17.7 1.6 21.8 14.1 13.6 1.9 21 9.5 299 8 298 165 6.8 0 7 6.5 09/29/2006 05:20:00 18.1 1.8 22.6 13.7 18.1 1.8 22.6 13.7 13.6 1.9 20.2 9.9 299 5 290 165 6.7 0.1 7 6.5 09/29/2006 05:30:00 18.7 1.6 22.6 14.5 18.7 1.6 22.6 14.9 14.2 1.9 21 10.3 298 6 298 165 6.8 0.1 7 6.2 09/29/2006 05:40:00 18.2 1.7 22.1 14.1 18.2 1.7 22.1 14.1 14.5 2.2 21 10.7 301 7 297 165 6.8 0.1 7 6.2 09/29/2006 05:50:00 19.4 2.1 24 14.5 19.4 2.1 24 14.1 15.4 2 21 9.9 301 7 305 165 6.9 0.1 7.3 6.2 09/29/2006 06:00:00 18.7 1.7 23.3 12.2 18.7 1.7 22.9 12.2 14.6 2.1 21 9.9 302 6 294 165 7.1 0 7.5 6.5 09/29/2006 06:10:00 17.9 1.9 23.7 13.3 17.8 1.9 23.7 13 14.2 2.5 22.1 9.9 301 7 302 165 7.1 0 7.3 6.7 09/29/2006 06:20:00 18.1 1.9 22.6 13 18.1 2 22.6 12.6 13.8 2 21 8.4 298 6 292 165 7.1 0 7.5 6.7 09/29/2006 06:30:00 18.8 1.5 22.6 14.5 18.9 1.5 22.1 14.5 14.3 2.1 19.5 9.1 297 5 290 165 7.2 0 7.5 6.7 09/29/2006 06:40:00 18.3 1.7 22.6 14.9 18.2 1.7 22.6 14.5 14.1 1.8 20.6 9.9 299 6 297 165 7.2 0 7.5 6.7 09/29/2006 06:50:00 16.5 2.2 21.4 11.8 16.5 2.2 21.4 11.8 13.4 2.5 18.7 8.4 302 7 300 165 7.3 0 7.5 7 09/29/2006 07:00:00 14.2 1.1 16.4 11.1 14.2 1.1 17.2 11.5 11.5 1.8 16.1 8 299 8 304 165 7.1 0 7.5 6.7 09/29/2006 07:10:00 15.3 2.2 20.6 10.3 15.2 2.2 20.2 10.3 12.9 2.5 19.1 8 305 7 325 165 7 0.1 7.3 6.5 09/29/2006 07:20:00 17.2 2.3 21.8 11.8 17 2.3 21.8 11.8 15 2.8 20.6 8.4 306 8 303 165 7.2 0.1 7.5 6.7 09/29/2006 07:30:00 19 1.7 23.3 14.1 18.9 1.7 23.7 14.1 16.7 2 21 11.1 308 6 304 165 7.6 0 7.8 7.3 09/29/2006 07:40:00 19.3 1.8 24 15.3 19.3 1.8 24 15.3 15.7 2.4 22.9 10.7 303 7 307 165 7.6 0 7.8 7.3 09/29/2006 07:50:00 18.8 1.8 24.8 15.3 18.7 1.8 25.2 14.9 14.9 2.5 23.3 10.7 302 6 307 165 7.9 0 8.3 7.5 09/29/2006 08:00:00 15.2 2.3 20.6 9.5 15.2 2.3 20.2 9.1 12.4 2.3 18.3 7.2 301 9 301 165 7.9 0.1 8.3 7.3 09/29/2006 08:10:00 13.3 2.4 18.3 7.6 13.2 2.4 18.7 8 11.4 2.6 17.6 5.7 302 11 308 165 7.7 0 8 7.5 09/29/2006 08:20:00 11.4 2.1 18.7 4.9 11.8 2.1 18.7 5.7 10.6 2.5 19.9 5.3 288 13 282 165 7.5 0 7.8 7.3 09/29/2006 08:30:00 13.4 2.1 17.9 7.6 13.5 2.2 17.9 7.6 12.2 2.5 17.2 6.1 286 8 291 165 7.4 0 7.8 7.3 09/29/2006 08:40:00 10.8 1.6 15.6 6.5 11 1.5 15.3 7.2 9.9 1.6 14.1 5.3 286 9 287 165 7.4 0 7.5 7.3 09/29/2006 08:50:00 12.1 2.2 16.8 6.5 12.5 1.9 16.8 7.2 11.5 2.2 16.8 6.1 284 10 272 165 7.5 0 7.8 7.3 09/29/2006 09:00:00 10.8 2.1 16.1 5.7 11.3 2 16.1 6.1 10.9 2 14.9 5.7 278 10 286 165 7.5 0 7.8 7.5 09/29/2006 09:10:00 8.4 2.1 14.5 4.9 9.4 1.9 14.1 5.7 8.7 1.7 13 5.3 277 11 290 165 7.4 0 7.8 7.3 09/29/2006 09:20:00 10 1.8 14.5 5.3 10.6 1.7 14.1 5.7 10.2 1.7 13.7 5.7 278 8 287 165 7.4 0 7.8 7.3 09/29/2006 09:30:00 10.6 2 15.3 6.5 11.2 1.9 15.3 6.8 10.7 2 15.3 6.1 278 8 279 165 7.8 0.2 8 7.3 09/29/2006 09:40:00 10 2.5 16.1 4.6 10.7 2 16.1 6.1 9.8 1.7 15.3 5.3 280 12 298 165 7.9 0.1 8.3 7.5 09/29/2006 09:50:00 6.8 2 13.3 3.8 7.7 1.7 13.3 4.9 7.5 1.5 13.3 4.6 270 9 279 165 7.9 0.2 8.3 7.3 09/29/2006 10:00:00 4.9 1.2 8.4 1.9 5.9 1.1 8.8 3.4 5.7 1 9.1 3.8 262 9 240 165 8 0.1 8.3 7.5 09/29/2006 10:10:00 5.8 1.3 8.8 2.6 6.1 1.3 9.5 3 5.7 1.2 9.5 3.4 282 12 270 165 8.1 0.2 8.8 7.5 09/29/2006 10:20:00 6.5 1.3 10.3 2.3 6.7 1.3 10.3 1.9 6 1.2 11.1 3.4 291 13 285 165 9.3 0.4 10.1 8.5 09/29/2006 10:30:00 6.5 1.7 10.7 2.6 7 1.8 10.7 2.3 6.5 1.8 11.1 2.6 278 14 287 165 10 0 10.3 9.3 09/29/2006 10:40:00 6.8 2.1 11.8 2.6 7.1 2.2 12.6 2.3 6.5 2.3 11.8 2.6 285 18 281 165 9.7 0.2 10.6 9 09/29/2006 10:50:00 7.9 2.1 12.6 2.6 8.1 1.9 12.2 2.6 7.6 2 12.2 3 282 11 300 165 9.4 0 9.8 9 09/29/2006 11:00:00 7.2 1.4 10.3 4.2 7.8 1 10.7 4.9 7.5 1 10.3 5.3 274 9 272 165 9.4 0.2 9.6 8.8 09/29/2006 11:10:00 8.3 1.5 11.1 4.6 8.7 1.5 11.5 4.6 8.3 1.7 11.5 3.8 279 9 287 165 9.6 0.1 9.8 9 09/29/2006 11:20:00 8.3 1.7 11.1 3.4 8.5 1.5 11.5 4.6 7.9 1.4 11.8 4.9 282 12 288 165 9.9 0.2 10.3 9 09/29/2006 11:30:00 10.4 1.8 13.3 6.1 10.6 1.7 13.7 6.5 9.7 1.7 13.3 5.7 284 10 289 165 9.9 0 10.3 9.3 09/29/2006 11:40:00 9.1 1.5 13 5.7 9.3 1.5 13.3 5.7 8.5 1.7 12.6 4.6 285 11 283 165 10.2 0.1 10.6 9.6 09/29/2006 11:50:00 10.8 1.7 15.3 6.1 11 1.8 15.6 6.5 10.3 2.3 16.1 5.7 283 8 280 165 10.1 0.1 10.6 9.8 09/29/2006 12:00:00 9.7 2.1 17.6 5.7 10 2.1 17.6 5.7 8.9 2.2 17.2 4.2 286 11 281 165 10.5 0.2 10.9 9.8 09/29/2006 12:10:00 10.9 1.5 14.9 5.7 11.2 1.5 14.9 7.2 10.6 1.8 14.5 6.1 283 10 298 165 10.5 0 10.9 10.3 09/29/2006 12:20:00 11.2 2 16.1 6.8 11.4 1.9 16.4 6.8 9.7 1.9 14.9 5.3 294 11 295 165 10.5 0 10.9 10.3 09/29/2006 12:30:00 12.3 1.8 16.4 7.6 12.4 1.7 16.4 8.4 11 1.9 16.4 7.2 289 10 298 165 10.5 0.1 10.9 10.3 09/29/2006 12:40:00 11.4 1.6 14.9 6.8 11.8 1.5 15.3 7.2 11.2 1.9 15.6 6.5 282 9 278 165 10.7 0 11.1 10.6 09/29/2006 12:50:00 11.4 1.5 15.6 7.6 11.6 1.5 15.3 7.6 10.8 1.7 16.4 6.5 283 9 280 165 10.7 0 10.9 10.6 09/29/2006 13:00:00 10.8 1.6 14.9 6.5 11.1 1.5 15.3 8 10.3 1.7 14.9 6.5 282 8 279 165 10.7 0.1 11.1 10.6 09/29/2006 13:10:00 12.2 1.5 16.1 7.6 12.6 1.3 16.4 8.8 11.6 1.5 16.4 6.8 284 9 304 165 10.7 0 10.9 10.6 09/29/2006 13:20:00 11.9 2.1 16.4 6.8 12 2 16.1 6.8 10.1 2 16.4 5.3 299 11 299 165 10.8 0 11.1 10.6 09/29/2006 13:30:00 9.8 1.6 15.3 6.1 9.9 1.5 15.3 6.5 8.2 1.5 12.2 4.2 294 10 304 165 11.1 0.2 11.7 10.9 09/29/2006 13:40:00 10.9 1.7 15.3 6.1 10.9 1.7 15.3 6.5 8.6 1.5 13 5.3 300 7 295 165 11.1 0.1 11.4 10.6 09/29/2006 13:50:00 9.7 1.4 14.1 5.7 9.8 1.4 13.7 6.1 8.3 1.4 13.3 5.3 296 9 287 165 10.1 0.1 10.6 9.8 09/29/2006 14:00:00 8.8 1.3 12.2 5.3 8.8 1.3 11.8 4.9 7.5 1.3 11.1 4.2 297 11 304 165 9.6 0.1 9.8 9.6 09/29/2006 14:10:00 9.6 1.1 12.6 5.7 9.7 1.2 12.6 6.1 9 1.5 12.2 4.9 283 7 279 165 9.3 0.1 9.6 9 09/29/2006 14:20:00 9.3 1.3 12.6 6.1 9.4 1.3 12.2 6.1 8.1 1.6 12.2 4.6 289 7 279 165 9.2 0 9.6 8.8 09/29/2006 14:30:00 8.6 1.1 10.7 5.3 8.7 1.1 10.7 5.3 7.8 1.6 11.1 3.8 286 8 281 165 9.2 0 9.3 9 09/29/2006 14:40:00 9.5 1.1 12.6 7.2 9.5 1.1 12.6 7.2 8.6 1.5 13 5.3 288 7 289 165 9.2 0 9.3 8.8 09/29/2006 14:50:00 8.6 1.1 11.5 5.7 8.8 1.1 11.5 6.1 7.9 1.5 12.2 3.8 288 11 307 165 9.1 0 9.3 9 09/29/2006 15:00:00 8.9 1.4 13 5.7 8.9 1.4 13 6.1 7.8 1.2 11.8 4.2 299 13 307 165 9.3 0.1 9.6 9 09/29/2006 15:10:00 11.7 1.9 16.8 7.6 11.6 1.9 16.4 8 9.7 1.5 13.7 6.5 303 8 305 165 9.3 0 9.6 9 09/29/2006 15:20:00 13.9 1.9 19.5 7.6 13.9 1.9 19.5 8 12 2.1 17.6 7.6 305 8 298 165 9.5 0.2 9.8 9 09/29/2006 15:30:00 15 1.6 19.5 10.7 14.9 1.7 19.1 10.7 12.6 2 18.3 7.6 303 9 296 165 9.6 0 9.8 9.6 09/29/2006 15:40:00 14.7 1.7 18.3 9.1 14.6 1.7 18.3 9.1 11.9 1.9 17.2 7.6 302 8 297 165 9.8 0.1 10.3 9 09/29/2006 15:50:00 14.3 2.3 19.9 9.9 14.2 2.3 19.9 9.5 11.6 2 17.6 7.6 304 8 294 165 10.1 0.2 10.6 9.6 09/29/2006 16:00:00 12.9 2 17.6 8.8 12.8 2 17.9 8.8 11.1 1.9 16.8 6.8 307 9 296 165 10.1 0 10.6 10.1 09/29/2006 16:10:00 13 2 17.2 7.6 12.9 2 16.8 8 11 1.7 15.6 7.2 307 8 313 165 10.1 0 10.6 9.8 09/29/2006 16:20:00 14.6 1.9 18.7 10.3 14.5 1.9 18.7 10.3 12.1 1.9 17.2 7.6 303 8 310 165 10 0.1 10.3 9.6 09/29/2006 16:30:00 13 1.7 16.8 9.5 13 1.7 16.8 9.5 10.2 1.5 15.3 6.8 301 7 299 165 10 0.1 10.3 9.3 09/29/2006 16:40:00 13.6 1.7 17.2 7.2 13.5 1.7 17.2 7.6 11.3 2 16.8 6.8 305 8 307 165 10.1 0 10.3 9.8 09/29/2006 16:50:00 13.6 1.3 17.6 10.7 13.5 1.3 17.6 10.3 10.9 1.6 15.6 7.6 305 7 298 165 9.7 0.3 10.3 9 09/29/2006 17:00:00 11.3 1.6 15.6 7.6 11.2 1.5 14.9 7.6 9.8 1.9 16.4 6.1 308 7 310 165 9 0.2 9.3 8.5 09/29/2006 17:10:00 10.9 1.3 14.1 7.2 10.8 1.3 14.1 7.6 9.8 1.5 14.1 6.5 308 11 320 165 9 0 9 8.5 09/29/2006 17:20:00 12.9 2.1 18.3 7.6 12.8 2.1 18.3 7.6 11.2 2 17.6 7.2 308 6 312 165 9 0 9.3 8.8 09/29/2006 17:30:00 14.5 1.5 18.3 10.3 14.4 1.6 18.7 10.3 11.8 2.1 19.5 8.4 306 6 297 165 9 0.1 9.3 8.5 09/29/2006 17:40:00 15.9 1.5 20.2 10.7 15.7 1.5 19.5 10.3 13.4 2 20.2 9.1 308 8 302 165 8.8 0 9 8.5 09/29/2006 17:50:00 14.6 1.6 18.3 10.3 14.5 1.6 18.3 10.3 12.3 1.8 17.2 8.4 308 7 310 165 8.7 0.1 9 8.3 09/29/2006 18:00:00 15.1 2.5 20.2 9.1 15 2.5 19.9 8.8 12.9 2.1 18.7 8 309 7 301 165 8.2 0 8.5 8 09/29/2006 18:10:00 14.3 1.8 18.3 9.9 14.1 1.8 18.3 9.9 12 1.8 16.8 7.6 306 8 301 165 8 0 8.3 7.5 09/29/2006 18:20:00 15 1.9 20.2 10.7 14.9 1.8 19.9 10.3 12.3 2.2 17.6 7.6 306 7 307 165 7.8 0 8 7.5 09/29/2006 18:30:00 14.8 1.9 19.9 8 14.7 1.9 19.5 9.5 12.9 2.2 19.1 8.8 309 8 312 165 7.7 0 8 7.5 09/29/2006 18:40:00 15 1.9 21 10.3 14.8 2 21 10.3 13.1 2.3 19.1 8.8 309 8 302 165 7.4 0.2 7.8 7 09/29/2006 18:50:00 13.6 2.3 19.1 9.1 13.5 2.4 19.5 8.8 10.7 2.1 16.8 6.8 302 7 304 165 7.2 0.2 7.8 6.7 09/29/2006 19:00:00 13.6 1.5 17.6 9.9 13.5 1.5 17.6 9.5 10.3 1.7 15.6 7.2 296 5 292 165 7.3 0 7.5 6.2 09/29/2006 19:10:00 13.1 1.7 17.2 9.1 13.1 1.7 17.2 9.1 10.7 2.1 17.6 6.1 295 7 289 165 7.2 0 7.8 6.7 09/29/2006 19:20:00 12.3 1.6 15.6 7.2 12.3 1.6 16.1 6.8 9.8 1.4 14.1 6.5 301 8 298 165 7.3 0 7.5 7 09/29/2006 19:30:00 12 1.6 16.1 8.4 11.9 1.6 15.6 8.4 9.8 1.7 14.5 6.8 301 9 301 165 6.9 0.1 7.3 6.7 09/29/2006 19:40:00 13.3 1.5 17.6 8.8 13.1 1.5 17.6 9.1 11.1 1.5 15.3 7.6 307 7 300 165 7.1 0 7.3 6.7 09/29/2006 19:50:00 13.6 1.8 17.6 8.8 13.5 1.7 17.2 8.8 12 2.1 16.4 6.5 308 8 315 165 7.1 0 7.3 6.7 09/29/2006 20:00:00 11.3 1.5 15.6 7.2 11.3 1.5 15.6 7.6 9.4 1.2 13.3 6.8 303 8 301 165 6.9 0 7.3 6.7 09/29/2006 20:10:00 12.2 1.7 17.2 8 12.2 1.7 17.2 8 9.8 1.7 15.6 6.1 302 8 302 165 6.9 0 7.3 6.5 09/29/2006 20:20:00 13.9 1.4 17.6 9.5 13.8 1.5 17.6 9.9 10.8 1.6 15.6 8 302 7 296 165 7 0 7.3 6.7 09/29/2006 20:30:00 13.5 1.6 17.9 9.5 13.4 1.6 17.9 9.5 10.6 1.4 15.3 7.6 303 7 296 165 6.9 0.1 7.3 6.5 09/29/2006 20:40:00 14.6 1.6 19.9 10.3 14.5 1.6 19.5 10.3 11.3 1.4 15.6 8.4 303 6 304 165 6.9 0.2 7.3 6.5 09/29/2006 20:50:00 15.1 1.9 19.9 10.7 15.1 1.9 19.5 10.3 11.6 1.8 16.4 8 299 7 300 165 7 0.1 7.3 6.2 09/29/2006 21:00:00 13.5 1.6 17.9 8.4 13.4 1.6 18.3 8.4 10.6 1.7 16.8 7.2 299 8 291 165 7 0.2 7.5 6.5 09/29/2006 21:10:00 14.6 1.5 18.3 11.5 14.6 1.5 18.3 11.1 11.4 1.6 16.1 7.6 300 7 292 165 6.9 0.2 7.3 6.2 09/29/2006 21:20:00 16.2 1.6 19.9 12.2 16.2 1.7 20.2 12.6 12.7 1.7 19.1 8.8 299 7 290 165 6.9 0.2 7.3 6.2 09/29/2006 21:30:00 15.9 1.5 20.2 11.5 15.8 1.5 20.2 11.1 12.5 1.9 17.6 8.8 295 7 286 165 7 0.2 7.3 6.5 09/29/2006 21:40:00 15.2 2 20.6 10.7 15.2 2.1 20.2 10.7 12.6 2.4 18.7 7.6 290 7 292 165 7 0.1 7.3 6.5 09/29/2006 21:50:00 12.3 1.9 16.8 7.6 12.3 1.9 16.4 7.6 9.9 2 15.6 5.7 295 8 289 165 6.9 0.2 7.3 6.2 09/29/2006 22:00:00 13.8 1.6 17.9 9.5 13.8 1.7 18.3 9.1 11 1.8 16.8 6.8 295 7 290 165 6.9 0.2 7.3 6.2 09/29/2006 22:10:00 15.1 2.1 20.6 9.9 15 2.1 19.9 9.5 11.8 1.8 17.6 7.6 297 7 296 165 7 0.2 7.3 6.2 09/29/2006 22:20:00 13.1 1.6 17.2 9.1 13.1 1.5 17.6 9.5 10.3 1.6 14.9 6.8 300 8 303 165 6.8 0 7 6.2 09/29/2006 22:30:00 11.7 1.2 15.6 8 11.6 1.3 15.3 8 9.5 1.5 13.7 5.7 298 9 295 165 6.7 0 7 6.5 09/29/2006 22:40:00 10.7 1.7 16.1 5.7 10.8 1.7 15.6 6.1 8.7 1.5 13 4.9 298 8 291 165 6.9 0.1 7.3 6.7 09/29/2006 22:50:00 10.6 1.2 14.1 6.5 10.6 1.2 13.7 6.8 8.5 1.4 13.7 5.3 301 7 296 165 6.7 0 7 6.7 09/29/2006 23:00:00 10.9 2 15.6 6.8 10.9 2 15.3 6.8 9.4 1.8 15.6 6.1 306 9 301 165 6.6 0 7 6.2 09/29/2006 23:10:00 11.6 1.3 14.5 8.8 11.6 1.3 14.9 8.4 9.4 1.2 12.2 6.5 300 8 300 165 6.6 0 6.7 6.2 09/29/2006 23:20:00 11.3 1.2 14.9 8 11.3 1.2 14.5 8 9.6 1.5 14.1 6.5 298 9 298 165 6.7 0 7 6.5 09/29/2006 23:30:00 10.3 1.6 14.1 6.8 10.3 1.6 14.1 6.8 8.2 1.3 12.2 5.3 302 7 302 165 6.6 0 6.7 6.2 09/29/2006 23:40:00 11.6 1.8 16.8 6.5 11.5 1.8 17.2 6.5 9 1.5 16.1 6.1 299 7 304 165 6.5 0 6.7 6.2 09/29/2006 23:50:00 11.2 1.6 16.8 7.2 11.1 1.5 16.8 8 9.2 1.7 16.4 6.1 303 8 302 165 6.6 0 6.7 6.2 09/30/2006 00:00:00 12.8 1.5 16.1 8 12.8 1.5 16.1 8 10.4 1.5 14.9 6.8 302 9 304 165 6.6 0 7 6.2 09/30/2006 00:10:00 10.9 1.3 14.9 7.6 10.8 1.3 15.3 7.6 9.5 1.6 13.7 6.1 308 8 309 165 6.3 0.1 6.7 6 09/30/2006 00:20:00 10.9 1.4 14.1 6.8 10.8 1.4 14.5 7.6 9.1 1.3 13.3 6.5 303 9 294 165 6.2 0 6.5 6 09/30/2006 00:30:00 10.9 1.5 15.6 6.8 10.9 1.5 14.9 6.8 8.9 1.3 14.1 5.7 304 8 297 165 6.3 0 6.5 6 09/30/2006 00:40:00 10 1.2 13 6.5 9.9 1.2 13 6.5 8.6 1.2 12.6 6.1 309 7 313 165 6.1 0.1 6.5 5.7 09/30/2006 00:50:00 8 1 10.3 5.7 8 1 10.3 5.7 7.7 1 9.9 5.7 317 9 318 165 5.8 0.1 6 5.7 09/30/2006 01:00:00 7.6 1.3 11.8 4.6 7.6 1.2 10.7 4.6 6.8 1.2 10.7 3.8 308 9 307 165 5.7 0.1 6 5.5 09/30/2006 01:10:00 8.5 1.3 11.1 4.6 8.4 1.2 11.1 4.6 7.3 1.3 10.7 3.4 308 8 311 165 5.7 0.1 6 5 09/30/2006 01:20:00 8.1 1.5 12.6 4.9 8.1 1.5 12.2 4.9 7.1 1.2 10.3 3.4 307 9 303 165 5.7 0.1 6 5 09/30/2006 01:30:00 6.3 1.5 11.5 2.6 6.4 1.5 11.1 2.6 5.6 1.2 9.1 3 301 12 311 165 5.7 0.2 6 5 09/30/2006 01:40:00 5.9 1.7 11.1 2.6 6 1.5 11.1 3.4 5.3 1.3 9.9 3 294 16 298 165 5.6 0 5.7 5 09/30/2006 01:50:00 4 1.2 6.8 1.1 4.1 1.2 6.8 1.5 3.8 1 6.5 1.9 282 11 275 165 5.6 0 5.7 5.5 09/30/2006 02:00:00 5.5 1.2 8.8 2.6 5.6 1.2 8.8 2.6 5.2 1.3 8.8 2.3 287 9 290 165 5.8 0.1 6.2 5.5 09/30/2006 02:10:00 5.4 0.9 7.6 2.6 5.4 0.9 7.6 2.6 4.5 0.8 6.5 2.6 296 10 297 165 5.7 0 6 5.5 09/30/2006 02:20:00 5.4 0.6 6.8 4.2 5.5 0.6 6.8 4.2 4.8 0.8 6.8 3 291 9 302 165 5.6 0 5.7 5.5 09/30/2006 02:30:00 5.9 0.9 8.4 3.4 6.6 0.9 8.8 4.2 6.6 0.9 9.1 3.4 273 9 269 165 5.7 0 6 5.5 09/30/2006 02:40:00 7.7 0.8 9.9 5.3 7.8 0.8 10.3 5.7 7.4 1.1 9.9 4.6 283 8 268 165 5.6 0 5.7 5.5 09/30/2006 02:50:00 9 0.6 10.3 6.8 9 0.7 10.7 6.8 7.9 1 10.7 5.3 290 4 293 165 5.6 0 5.7 5.5 09/30/2006 03:00:00 9.4 1.4 12.6 4.9 9.6 1.3 13 5.7 8.9 1.4 12.6 5.7 285 6 284 165 5.5 0.1 5.7 5.2 09/30/2006 03:10:00 10 1.3 12.6 6.8 10.1 1.3 12.6 7.2 9.1 1.5 12.6 4.9 287 5 272 165 5.7 0 6 5.5 09/30/2006 03:20:00 6.7 0.8 9.1 4.6 6.9 0.8 9.1 4.6 6.5 1.3 9.5 3.4 285 7 278 165 5.7 0.1 6 5.5 09/30/2006 03:30:00 6.9 1 10.7 4.6 7.1 1 11.1 5.3 6.7 1.3 10.3 3.8 284 9 286 165 5.9 0 6.2 5.5 09/30/2006 03:40:00 9.3 1 11.5 6.1 9.9 0.9 11.8 6.5 9.6 1 12.6 6.1 280 7 282 165 5.8 0 6 5.5 09/30/2006 03:50:00 10 1 12.6 7.6 10.1 1 12.6 8 8.9 1.3 12.2 5.7 287 6 281 165 5.7 0 6 5.5 09/30/2006 04:00:00 8.6 1.6 12.6 4.6 8.7 1.5 12.6 4.9 7.8 1.5 11.5 4.2 285 6 285 165 5.8 0 6 5.7 09/30/2006 04:10:00 7.9 1 11.1 5.3 8.3 1 11.1 6.5 7.9 1.1 11.5 5.7 282 7 277 165 5.7 0.1 6 5.5 09/30/2006 04:20:00 6.4 1.5 9.1 2.6 6.6 1.5 9.1 3.4 5.4 2.1 9.1 0.7 290 7 282 165 5.5 0.1 5.7 5.2 09/30/2006 04:30:00 2.9 1.6 6.5 0.4 3 1.7 6.5 0.4 2.8 1.3 6.5 0.4 270 47 290 165 5.4 0.2 5.7 5 09/30/2006 04:40:00 3.9 1.3 6.8 0.4 4.1 1.2 7.6 0.7 3.4 1 6.5 1.1 284 20 291 165 5.6 0 5.7 5.5 09/30/2006 04:50:00 2.5 0.9 4.6 0.7 2.9 0.8 4.6 0.7 2.8 0.6 4.9 1.1 273 15 284 165 5.3 0.1 5.7 5 09/30/2006 05:00:00 2 1.2 5.3 0.4 2.2 1.3 5.7 0.4 2.3 1 4.6 0.4 241 26 266 165 5.2 0.1 5.7 5 09/30/2006 05:10:00 3.7 0.9 5.3 1.9 4 0.8 5.7 2.3 4 0.8 5.7 2.3 276 11 277 165 5.7 0 5.7 5.5 09/30/2006 05:20:00 3.7 0.6 5.7 1.9 4 0.6 5.7 2.6 3.9 0.8 6.1 1.9 281 11 282 165 5.7 0 5.7 5.5 09/30/2006 05:30:00 1.8 1.2 4.6 0.4 1.8 1.3 4.6 0.4 1.7 1.1 3.8 0.4 258 30 303 165 5.4 0.1 5.7 5 09/30/2006 05:40:00 2.9 0.8 5.3 1.1 3.4 0.8 5.3 0.7 3.3 0.8 5.3 0.4 260 13 249 165 5.2 0 5.5 5 09/30/2006 05:50:00 3.6 0.7 4.9 1.5 4 0.5 5.7 2.3 4 0.5 5.3 2.3 252 8 251 165 5.3 0 5.5 5.2 09/30/2006 06:00:00 4 0.6 5.7 2.3 4.1 0.5 5.3 3 4.2 0.4 5.7 3.4 246 4 245 165 5.6 0 5.7 5.5 09/30/2006 06:10:00 3.5 0.4 4.6 2.6 3.5 0.5 4.6 2.6 3.6 0.5 4.9 2.6 241 8 244 165 5.5 0 5.7 5.2 09/30/2006 06:20:00 1.7 0.6 3.4 0.4 1.5 0.7 3 0.4 2.1 0.5 3.4 0.7 183 11 208 165 5.2 0.1 5.7 5 09/30/2006 06:30:00 0.6 0.3 1.5 0.4 0.4 0.2 1.5 0.4 1.3 0.3 1.9 0.7 195 7 199 165 5.2 0 5.5 5 09/30/2006 06:40:00 0.9 0.4 2.6 0.4 0.6 0.4 2.6 0.4 1.1 0.4 1.9 0.4 201 22 195 165 5.1 0 5.5 5 09/30/2006 06:50:00 1.2 0.8 3 0.4 1.3 1 3 0.4 1.5 0.9 3 0.4 239 19 244 165 5.2 0 5.5 5 09/30/2006 07:00:00 2.2 0.7 3.4 0.4 2.1 0.7 3.4 0.4 2.4 0.5 3.4 1.1 230 24 245 165 5.3 0.1 5.5 5 09/30/2006 07:10:00 0.7 0.4 1.5 0.4 0.5 0.3 1.9 0.4 1.3 0.3 2.3 0.4 174 13 185 165 5.6 0.2 6 5.2 09/30/2006 07:20:00 1.6 0.3 2.6 0.4 1.4 0.4 2.3 0.4 1.8 0.3 2.3 1.1 148 8 140 165 5.9 0 6.2 5.7 09/30/2006 07:30:00 0.7 0.5 1.9 0.4 0.7 0.4 1.9 0.4 1 0.6 2.3 0.4 151 3 147 165 6.4 0.2 7 6 09/30/2006 07:40:00 0.4 0.1 1.1 0.4 0.4 0.1 1.1 0.4 0.7 0.4 1.9 0.4 261 38 288 165 6.9 0.1 7.3 6.5 09/30/2006 07:50:00 0.5 0.2 1.1 0.4 0.4 0.1 0.7 0.4 1 0.4 1.9 0.4 177 38 162 165 7.4 0.1 7.5 7 09/30/2006 08:00:00 0.9 0.4 1.5 0.4 0.7 0.3 1.1 0.4 1.3 0.6 2.3 0.4 163 9 150 165 7.5 0.1 8 7.3 09/30/2006 08:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.6 0.3 1.1 0.4 204 20 165 165 8.2 0 8.5 7.5 09/30/2006 08:20:00 1.5 0.6 2.6 0.4 1.3 0.6 3 0.4 2 0.6 3 0.4 156 17 157 165 7.9 0.4 8.5 7 09/30/2006 08:30:00 0.8 0.3 1.5 0.4 0.6 0.3 1.1 0.4 1.5 0.3 1.9 0.4 153 0 153 165 7 0 7.3 6.7 09/30/2006 08:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0.1 1.1 0.4 153 1 165 165 8 0.4 8.5 6.7 09/30/2006 08:50:00 1.1 0.8 3 0.4 1 0.7 2.6 0.4 1.5 0.9 3.4 0.4 214 29 189 165 8.5 0 8.8 8 09/30/2006 09:00:00 2.3 0.4 3.4 1.5 2.2 0.4 3.4 1.1 2.8 0.5 3.8 1.5 192 4 194 165 8.5 0 8.8 8.5 09/30/2006 09:10:00 2.8 0.4 4.2 1.9 2.7 0.4 4.2 1.5 3.1 0.3 4.2 2.3 196 9 177 165 8.6 0 8.8 8.5 09/30/2006 09:20:00 2.6 0.3 3.4 1.5 2.4 0.4 3.4 1.1 3 0.3 3.8 1.9 201 5 201 165 8.5 0 8.8 8.5 09/30/2006 09:30:00 2.2 0.6 3.8 0.4 1.9 0.7 3.8 0.4 2.5 0.5 4.2 1.5 170 16 167 165 8.9 0.2 9.3 8.5 09/30/2006 09:40:00 2.6 0.8 4.2 0.4 2.4 0.8 4.2 0.4 2.9 0.7 4.6 1.1 171 11 176 165 9.4 0.2 9.8 9 09/30/2006 09:50:00 2.8 0.6 4.2 0.7 2.6 0.6 3.8 0.7 3.1 0.5 4.9 1.9 167 11 181 165 9.8 0.1 10.6 9.6 09/30/2006 10:00:00 2.9 0.5 4.6 1.1 2.7 0.6 4.6 0.7 3.3 0.5 4.6 1.9 163 9 164 165 9.6 0 10.1 9.3 09/30/2006 10:10:00 2.9 0.5 4.2 1.5 2.7 0.5 4.2 1.5 3.2 0.5 4.2 1.5 158 7 175 165 9.4 0 9.6 9.3 09/30/2006 10:20:00 2.9 0.4 4.2 1.5 2.7 0.5 3.8 1.1 3.2 0.5 4.6 1.9 161 7 150 165 9.4 0 9.6 9.3 09/30/2006 10:30:00 2.9 0.5 4.2 1.5 2.7 0.6 4.2 1.1 3.3 0.6 4.9 2.3 156 8 144 165 9.4 0 9.6 9 09/30/2006 10:40:00 3 0.5 4.2 1.9 2.9 0.5 4.2 1.9 3.3 0.5 4.9 1.9 156 11 153 165 9.3 0.1 9.6 9 09/30/2006 10:50:00 2.8 0.6 4.2 1.1 2.6 0.7 4.2 0.7 3.1 0.6 4.6 1.5 149 13 169 165 9.8 0.2 10.3 9.3 09/30/2006 11:00:00 2.7 0.6 4.6 0.4 2.5 0.6 4.2 0.4 3 0.5 4.6 1.9 153 13 145 165 9.8 0.1 10.6 9.6 09/30/2006 11:10:00 3.2 0.7 4.6 1.9 3 0.7 4.6 1.5 3.5 0.7 4.9 1.9 163 12 143 165 9.9 0.1 10.6 9.6 09/30/2006 11:20:00 2.8 0.6 4.2 1.1 2.6 0.6 3.8 1.1 3 0.5 4.6 1.9 174 10 182 165 10.1 0.1 10.9 9.8 09/30/2006 11:30:00 4 0.6 5.3 2.6 3.8 0.6 5.3 2.3 4.4 0.6 5.7 2.6 167 8 163 165 10.2 0.2 11.1 9.8 09/30/2006 11:40:00 3.7 0.5 4.9 1.9 3.5 0.6 4.6 1.9 3.9 0.5 5.3 2.3 159 11 154 165 9.4 0.2 10.3 9 09/30/2006 11:50:00 3.3 0.4 4.6 2.3 3.2 0.5 4.2 1.9 3.6 0.4 4.9 2.6 157 8 149 165 9.3 0 9.6 9 09/30/2006 12:00:00 3.7 0.5 4.9 2.3 3.5 0.5 4.9 2.3 3.9 0.4 4.9 2.6 147 6 135 165 9 0 9.6 8.8 09/30/2006 12:10:00 3.5 0.4 4.6 2.6 3.5 0.4 4.6 2.6 3.8 0.5 5.3 3 149 8 151 165 9.2 0.1 9.6 8.8 09/30/2006 12:20:00 3.8 0.3 4.6 2.6 3.7 0.3 4.9 3 4.2 0.3 5.7 3 145 5 139 165 8.7 0.1 9.6 8.5 09/30/2006 12:30:00 3.8 0.5 5.3 2.6 3.7 0.4 4.9 2.6 4 0.5 5.3 3 143 7 143 165 8.7 0 8.8 8.5 09/30/2006 12:40:00 3.3 0.3 3.8 2.6 3.3 0.3 4.2 2.6 3.5 0.3 4.6 2.6 146 7 144 165 8.6 0.1 9 8.5 09/30/2006 12:50:00 3.7 0.5 4.6 2.3 3.6 0.5 4.6 2.3 3.9 0.4 4.9 2.6 148 5 150 165 8.7 0 9.3 8.5 09/30/2006 13:00:00 3.9 0.5 5.7 2.6 3.8 0.5 5.7 2.3 4.1 0.4 6.1 3.4 145 7 126 165 8.9 0 9 8.8 09/30/2006 13:10:00 3.9 0.5 5.7 2.6 3.8 0.5 5.7 2.6 4.1 0.5 5.3 2.6 143 8 136 165 8.6 0.1 8.8 8.5 09/30/2006 13:20:00 3.8 0.4 4.9 2.3 3.7 0.4 4.9 2.3 4 0.3 4.9 3 142 6 141 165 8.4 0.1 8.8 8.3 09/30/2006 13:30:00 4 0.5 4.9 2.6 3.9 0.5 4.9 2.6 4.2 0.4 4.9 2.6 137 7 136 165 8.5 0 8.8 8.3 09/30/2006 13:40:00 2.7 0.5 3.8 1.1 2.7 0.5 4.6 1.5 3.2 0.5 4.6 2.3 139 9 136 165 9.1 0.1 9.3 8.8 09/30/2006 13:50:00 2.1 0.4 3 0.7 2.2 0.4 3.4 1.1 2.6 0.4 3.4 1.5 140 7 139 165 9 0 9.3 8.8 09/30/2006 14:00:00 2.8 0.8 4.6 0.4 2.9 0.7 4.6 1.1 3.2 0.7 4.9 1.9 155 12 147 165 10.1 0.4 10.9 9.3 09/30/2006 14:10:00 2.9 0.5 4.9 1.9 2.8 0.5 4.9 1.5 3.2 0.5 4.6 2.3 162 12 165 165 10.1 0 10.3 9.8 09/30/2006 14:20:00 2.5 0.6 3.8 0.7 2.4 0.6 3.8 0.7 2.9 0.5 4.2 1.9 154 8 163 165 9.7 0.1 9.8 9.6 09/30/2006 14:30:00 2.6 0.4 3.8 1.9 2.5 0.4 3.8 1.5 3 0.4 4.6 2.3 146 7 150 165 9.7 0.1 10.3 9.6 09/30/2006 14:40:00 3.1 0.5 4.2 1.5 3 0.5 4.2 1.5 3.4 0.5 4.6 1.9 152 8 152 165 9.8 0.1 10.6 9.6 09/30/2006 14:50:00 3.1 0.5 4.2 1.5 3 0.4 4.2 1.9 3.4 0.4 4.6 2.3 154 8 152 165 9.6 0 9.6 9.3 09/30/2006 15:00:00 3.1 0.6 4.9 1.5 3 0.6 4.9 1.5 3.4 0.6 4.9 2.3 146 9 150 165 10.6 0.4 11.4 9.6 09/30/2006 15:10:00 3.3 0.5 4.6 1.5 3.2 0.5 4.2 1.9 3.6 0.5 4.9 2.3 150 8 143 165 10.7 0.1 11.1 10.3 09/30/2006 15:20:00 2.7 0.5 4.2 1.1 2.6 0.5 3.8 1.1 3.1 0.4 4.2 1.5 153 12 149 165 9.9 0.1 10.3 9.6 09/30/2006 15:30:00 2.5 0.8 4.6 0.4 2.4 0.7 4.2 0.4 2.8 0.6 4.2 1.1 174 12 180 165 9.6 0 9.8 9.6 09/30/2006 15:40:00 3.8 0.9 5.3 1.1 3.7 0.9 5.3 0.7 4 0.8 6.1 1.9 181 9 176 165 9.6 0 9.6 9.3 09/30/2006 15:50:00 5.1 0.7 6.5 3.4 5.1 0.6 6.1 3 5.2 0.7 6.8 3.4 190 12 192 165 9.4 0 9.6 9.3 09/30/2006 16:00:00 5 0.7 6.5 3.4 4.9 0.6 6.1 3.4 5.2 0.6 6.5 3.4 188 11 183 165 9.4 0 9.6 9 09/30/2006 16:10:00 4.2 0.7 6.5 2.6 4.2 0.7 6.1 2.3 4.3 0.6 7.2 2.6 189 12 196 165 9.4 0 9.6 9 09/30/2006 16:20:00 4.6 0.9 6.8 2.6 4.5 0.9 6.8 2.3 4.7 0.8 6.8 3 185 12 196 165 9.4 0 9.6 9.3 09/30/2006 16:30:00 5.2 1 7.2 3 5 0.9 7.2 3 5.2 0.8 7.2 3.4 180 9 182 165 9.2 0.1 9.6 8.8 09/30/2006 16:40:00 6.5 0.8 8 4.2 6.4 0.8 8 4.6 6.4 0.8 8 3.8 188 7 192 165 9.2 0 9.6 9 09/30/2006 16:50:00 5.3 0.8 7.6 3 5.1 0.8 7.6 3 5.5 0.7 7.6 3.8 171 12 182 165 9.2 0.1 9.6 8.8 09/30/2006 17:00:00 5.5 0.6 7.6 4.2 5.3 0.6 7.6 4.2 5.5 0.5 7.2 4.6 178 9 196 165 9 0 9 8.8 09/30/2006 17:10:00 6.1 0.7 7.6 4.2 6.1 0.7 7.6 4.2 6.3 0.7 8 4.2 187 6 192 165 9 0 9.3 8.8 09/30/2006 17:20:00 5.6 0.6 6.8 4.2 5.6 0.6 6.8 3.8 6 0.7 7.2 3.8 190 4 187 165 8.9 0 9 8.8 09/30/2006 17:30:00 3.6 0.5 5.3 2.3 3.5 0.5 5.3 2.3 3.7 0.5 4.9 2.6 184 9 194 165 8.8 0 9 8.5 09/30/2006 17:40:00 3.4 0.5 4.9 1.9 3.2 0.5 4.6 1.5 3.7 0.5 4.9 2.3 176 10 178 165 8.6 0.1 9.3 8.3 09/30/2006 17:50:00 3.5 0.5 4.9 2.3 3.3 0.4 4.6 2.3 3.8 0.4 4.6 3 170 6 173 165 8.5 0.1 8.8 8.3 09/30/2006 18:00:00 4.8 0.9 6.5 2.6 4.6 0.8 6.5 2.6 5 0.8 6.8 3.4 173 11 178 165 8.5 0.1 8.8 7.8 09/30/2006 18:10:00 5.7 0.5 6.8 4.2 5.4 0.5 6.8 4.2 5.8 0.5 6.8 4.6 176 5 176 165 8.4 0 8.5 7.8 09/30/2006 18:20:00 5.8 0.6 6.8 4.2 5.5 0.5 6.8 4.2 5.8 0.6 7.2 4.2 177 5 179 165 8.3 0 8.5 7.8 09/30/2006 18:30:00 5.6 0.6 6.8 3.8 5.4 0.6 6.8 3.4 5.7 0.6 6.8 4.2 176 10 178 165 8.3 0 8.5 7.8 09/30/2006 18:40:00 5.6 0.8 7.2 3.8 5.4 0.7 6.8 3.8 5.6 0.7 7.6 4.2 174 6 170 165 8.3 0 8.8 7.8 09/30/2006 18:50:00 5.2 0.5 6.5 3.8 5 0.5 6.5 3.8 5.3 0.5 6.5 3.8 183 6 180 165 8.3 0 8.5 7.8 09/30/2006 19:00:00 4.4 0.7 6.1 2.6 4.3 0.7 5.7 2.3 4.6 0.6 6.5 3 181 7 180 165 8.3 0 8.5 7.8 09/30/2006 19:10:00 4.5 0.8 6.1 2.6 4.4 0.8 6.1 2.6 4.8 0.8 6.5 3 180 6 179 165 8.3 0 8.5 7.8 09/30/2006 19:20:00 4.9 0.6 6.5 3 4.7 0.5 6.1 2.6 5.2 0.6 6.5 3.4 183 6 170 165 8.3 0 8.5 7.8 09/30/2006 19:30:00 4.9 0.6 6.5 3.4 4.6 0.6 6.1 3 5 0.6 6.8 3.4 177 5 175 165 8.3 0 8.5 8.3 09/30/2006 19:40:00 4 0.6 4.9 2.6 3.8 0.6 4.6 2.3 4.2 0.5 5.3 3 177 5 169 165 8.3 0 8.5 8 09/30/2006 19:50:00 4.2 0.5 4.9 2.3 4 0.5 4.9 1.9 4.4 0.5 5.7 2.6 173 6 177 165 8.3 0 8.5 8 09/30/2006 20:00:00 3.7 0.7 5.3 2.3 3.5 0.7 5.3 1.9 3.9 0.6 5.3 2.6 175 8 176 165 8.3 0 8.5 8 09/30/2006 20:10:00 5.8 0.8 7.6 3.4 5.6 0.7 7.2 3.4 6 0.8 8 3.8 171 7 165 165 8.3 0 8.5 8 09/30/2006 20:20:00 6.4 0.5 7.6 5.3 6.1 0.4 7.2 4.9 6.5 0.5 7.6 4.9 172 5 176 165 8.3 0 8.5 8 09/30/2006 20:30:00 6.5 0.6 7.6 4.9 6.3 0.6 7.6 4.9 6.7 0.7 8 4.9 167 4 164 165 8.3 0 8.5 8 09/30/2006 20:40:00 7.1 0.5 8.4 5.7 6.8 0.4 7.6 5.7 7.1 0.6 8.4 5.3 166 10 165 165 8.3 0 8.5 8.3 09/30/2006 20:50:00 6.8 0.4 7.6 5.7 6.6 0.3 7.2 5.3 7 0.4 7.6 5.7 164 15 164 165 8.3 0 8.5 8 09/30/2006 21:00:00 6.9 0.4 7.6 5.7 6.6 0.4 7.6 5.3 7 0.5 8 6.1 166 3 165 165 8.2 0 8.5 8 09/30/2006 21:10:00 6.9 0.4 8 5.7 6.6 0.3 7.6 5.3 7.2 0.4 8.4 6.1 167 13 171 165 8.1 0 8.5 8 09/30/2006 21:20:00 6.7 0.4 7.6 5.7 6.4 0.3 7.2 5.3 6.9 0.4 8 5.7 168 3 171 165 8 0 8.3 7.8 09/30/2006 21:30:00 7.3 0.4 8.8 5.7 7 0.4 8.4 5.7 7.5 0.5 8.8 5.7 172 7 162 165 8 0 8.3 7.8 09/30/2006 21:40:00 8.6 0.7 10.3 6.8 8.4 0.7 9.9 6.5 8.8 0.7 10.3 6.8 172 5 173 165 8 0 8.3 7.8 09/30/2006 21:50:00 9.4 0.6 11.1 7.6 9.1 0.6 10.7 7.2 9.6 0.7 11.1 7.6 170 4 164 165 8 0 8.3 7.8 09/30/2006 22:00:00 9.9 0.7 11.5 8 9.6 0.7 11.1 8 10.1 0.8 11.5 7.6 170 5 165 165 7.9 0.1 8.3 7.5 09/30/2006 22:10:00 9.8 0.6 11.5 8 9.5 0.6 11.1 8 10 0.7 11.5 8 169 6 165 165 7.9 0.1 8.3 7.5 09/30/2006 22:20:00 8.5 0.4 9.9 7.6 8.2 0.4 9.1 7.2 8.9 0.5 9.9 7.6 170 4 173 165 7.8 0.2 8.3 7.5 09/30/2006 22:30:00 8.2 0.6 9.5 6.1 7.9 0.5 9.5 6.5 8.4 0.6 9.9 6.8 170 4 170 165 7.8 0.2 8 7.5 09/30/2006 22:40:00 8.7 0.5 9.9 7.2 8.4 0.5 9.5 7.2 8.9 0.6 10.3 7.2 170 4 168 165 7.6 0.1 8 7.3 09/30/2006 22:50:00 8.5 0.7 9.9 6.8 8.2 0.6 9.9 6.5 8.8 0.7 10.3 6.8 173 5 176 165 7.4 0.1 7.8 7.3 09/30/2006 23:00:00 8.1 0.4 9.5 6.5 7.8 0.4 9.5 6.1 8.4 0.5 9.9 6.8 171 5 168 165 7.4 0.2 7.8 7 09/30/2006 23:10:00 8.3 0.6 9.9 6.8 7.9 0.6 9.1 6.5 8.5 0.6 10.3 6.8 169 7 167 165 7.4 0.2 7.8 7 09/30/2006 23:20:00 8.6 0.7 10.3 7.2 8.2 0.6 9.9 6.8 8.7 0.7 10.3 6.8 172 5 168 165 7.4 0.1 7.5 7 09/30/2006 23:30:00 8.2 0.5 9.1 6.8 7.8 0.5 8.8 6.5 8.4 0.5 9.5 6.5 171 17 176 165 7.4 0.1 7.5 6.7 09/30/2006 23:40:00 8 0.6 9.5 6.5 7.6 0.6 8.8 6.5 8 0.7 9.5 6.8 167 3 165 165 7.4 0.1 7.5 7 09/30/2006 23:50:00 7.8 0.5 9.5 6.1 7.6 0.5 9.1 6.5 8 0.5 9.5 6.5 162 4 157 165 7.4 0.1 7.8 7 10/01/2006 00:00:00 8 0.6 9.5 6.5 7.8 0.6 9.5 6.5 8 0.6 9.5 6.1 161 7 163 165 7.6 0 7.8 7.3 10/01/2006 00:10:00 7.4 0.5 8.8 6.1 7.3 0.5 8.4 6.1 7.6 0.6 9.1 5.7 157 4 152 165 7.6 0 7.8 7.3 10/01/2006 00:20:00 6.7 0.5 8.4 5.3 6.6 0.5 8 5.3 7 0.5 8.4 6.1 162 4 160 165 7.7 0 7.8 7.3 10/01/2006 00:30:00 6.3 0.8 8.4 4.6 6.2 0.8 8 4.6 6.5 0.8 8.8 4.9 164 15 166 165 7.8 0 8 7.3 10/01/2006 00:40:00 8.2 0.8 10.3 6.1 8 0.8 9.9 6.1 8.3 0.9 11.1 6.5 166 9 170 165 7.7 0 7.8 7.5 10/01/2006 00:50:00 10.5 1.1 12.6 8 10.3 1 12.2 8 10.6 1.1 13 7.6 165 10 171 165 7.6 0 7.8 7.3 10/01/2006 01:00:00 11.7 0.6 13 9.5 11.4 0.6 13 9.5 11.7 0.6 13.3 9.9 166 11 165 165 7.6 0 7.8 7.3 10/01/2006 01:10:00 10.5 0.7 12.6 8.8 10.3 0.7 12.2 8.8 10.6 0.8 12.6 8.4 166 16 167 165 7.6 0 7.8 7.3 10/01/2006 01:20:00 9.1 0.7 10.7 7.6 8.9 0.6 10.3 7.2 9.2 0.7 11.1 7.6 165 4 165 165 7.7 0 7.8 7.5 10/01/2006 01:30:00 8 0.6 9.9 6.5 7.8 0.6 9.5 6.8 8.1 0.6 9.5 6.1 163 3 165 165 7.6 0 7.8 7.5 10/01/2006 01:40:00 6.6 0.6 8 4.9 6.6 0.6 8 4.9 6.8 0.7 8.4 5.3 155 5 156 165 7.6 0 7.8 7.5 10/01/2006 01:50:00 7.6 0.5 9.1 6.5 7.5 0.5 9.1 6.5 7.6 0.4 9.5 6.5 148 3 142 165 7.7 0 8 7.3 10/01/2006 02:00:00 8.5 0.7 10.7 6.8 8.4 0.7 10.3 6.8 8.5 0.6 10.7 6.8 151 5 154 165 7.8 0 8 7.5 10/01/2006 02:10:00 10 0.8 11.5 8 9.9 0.8 11.5 7.6 10 0.8 11.8 8 154 3 152 165 8 0 8.3 7.5 10/01/2006 02:20:00 11.1 0.7 13.3 9.1 11 0.8 13.3 9.1 11.2 0.8 13.3 8.8 156 3 160 165 8.1 0 8.3 7.8 10/01/2006 02:30:00 10.6 0.8 12.6 8.4 10.5 0.8 12.2 8 10.8 0.8 13 8.4 158 7 157 165 8.2 0 8.5 8 10/01/2006 02:40:00 10.8 0.8 13 8.8 10.7 0.8 13 8.4 11 0.8 13.3 8.4 158 3 160 165 8.2 0 8.5 8 10/01/2006 02:50:00 9.6 0.6 11.1 8 9.5 0.6 10.7 8 9.8 0.7 11.5 8 156 2 156 165 8.3 0 8.5 8.3 10/01/2006 03:00:00 8.4 0.6 10.3 6.8 8.3 0.6 10.3 6.8 8.5 0.6 9.9 6.8 157 4 167 165 8.3 0 8.5 8.3 10/01/2006 03:10:00 8.7 0.7 11.1 6.8 8.5 0.7 10.7 6.5 8.7 0.6 9.9 7.2 155 5 160 165 8.4 0 8.5 7.8 10/01/2006 03:20:00 8.4 0.6 9.9 6.5 8.3 0.6 9.9 6.1 8.5 0.6 10.3 6.8 156 3 162 165 8.5 0.1 8.5 7.8 10/01/2006 03:30:00 9.1 0.6 11.5 7.6 8.9 0.6 10.7 7.6 9.1 0.6 10.7 7.2 158 3 165 165 8.5 0.1 8.8 7.8 10/01/2006 03:40:00 8.8 0.7 11.1 7.2 8.6 0.6 10.7 7.2 9 0.6 10.7 7.2 158 4 160 165 8.5 0.1 8.5 8 10/01/2006 03:50:00 8.6 0.9 11.5 6.5 8.3 0.9 10.7 6.5 8.6 0.8 11.1 6.1 163 9 173 165 8.5 0.1 8.8 7.8 10/01/2006 04:00:00 9.9 0.8 11.8 8 9.6 0.7 11.5 8 10 0.7 11.8 7.2 166 14 176 165 8.6 0.1 9 8 10/01/2006 04:10:00 9.2 0.8 11.1 7.2 8.9 0.7 11.1 7.2 9.1 0.7 11.1 7.2 166 13 165 165 8.5 0.2 8.8 8 10/01/2006 04:20:00 7.6 0.9 9.9 6.1 7.4 0.8 9.5 5.7 7.6 0.8 9.9 6.1 163 3 164 165 8.6 0.2 8.8 8.3 10/01/2006 04:30:00 6.6 0.7 8.4 4.9 6.4 0.6 8.4 4.9 6.7 0.6 9.1 4.9 161 4 163 165 8.5 0.1 8.8 8.3 10/01/2006 04:40:00 6.1 0.8 8.8 4.2 6 0.7 8.4 4.2 6.3 0.7 8.4 4.6 156 6 148 165 8.6 0 8.8 8.3 10/01/2006 04:50:00 5.7 0.6 7.6 3.4 5.6 0.6 7.2 3.4 5.9 0.5 7.6 4.2 151 6 161 165 8.7 0 8.8 8.3 10/01/2006 05:00:00 6.2 0.6 7.6 4.6 6.1 0.5 7.6 4.6 6.3 0.6 7.6 4.6 150 5 154 165 8.7 0 8.8 8.3 10/01/2006 05:10:00 6.5 0.4 7.6 5.3 6.5 0.4 7.6 5.3 6.7 0.4 7.6 5.7 149 4 151 165 8.7 0 9 8.5 10/01/2006 05:20:00 6.3 0.5 7.6 5.3 6.3 0.5 7.6 5.3 6.5 0.5 7.6 4.2 148 5 152 165 8.7 0 9 8.5 10/01/2006 05:30:00 7.3 0.7 9.5 5.7 7.1 0.7 9.5 5.7 7.3 0.6 9.5 6.1 151 5 147 165 8.7 0 9 8.5 10/01/2006 05:40:00 7.6 0.7 9.5 5.7 7.5 0.7 9.1 5.3 7.8 0.6 9.5 6.1 156 6 151 165 8.8 0 9 8.5 10/01/2006 05:50:00 8.6 0.7 10.7 6.8 8.5 0.7 10.3 6.8 8.6 0.7 10.3 6.5 157 5 164 165 8.9 0.1 9 8.5 10/01/2006 06:00:00 7.8 0.7 9.5 6.5 7.6 0.6 9.1 6.1 8 0.7 9.9 6.1 157 11 159 165 8.9 0.2 9.3 8.5 10/01/2006 06:10:00 7.8 0.8 9.9 5.7 7.7 0.8 10.3 6.1 7.9 0.8 9.9 5.7 156 6 148 165 8.9 0.2 9 8.5 10/01/2006 06:20:00 7.4 0.7 9.1 6.1 7.3 0.7 9.1 5.7 7.4 0.7 9.5 5.7 155 5 154 165 8.9 0.2 9 8.5 10/01/2006 06:30:00 8.1 0.7 9.5 6.1 8 0.7 9.5 6.1 8.2 0.6 9.9 6.8 158 4 156 165 8.9 0.1 9 8.3 10/01/2006 06:40:00 7 1.1 10.3 5.3 6.8 1.1 9.9 5.3 7.2 0.9 9.5 5.7 161 10 165 165 8.9 0.2 9 8.5 10/01/2006 06:50:00 5.8 0.5 6.8 4.9 5.6 0.5 6.8 4.6 6.1 0.5 6.8 4.9 159 2 158 165 8.9 0.2 9 8.3 10/01/2006 07:00:00 5.5 0.5 6.5 4.2 5.5 0.5 6.5 4.6 5.6 0.5 6.5 4.6 154 4 153 165 8.9 0 9 8.5 10/01/2006 07:10:00 6.6 0.6 8.4 4.6 6.6 0.6 8.4 4.2 6.7 0.6 8 4.6 155 4 155 165 8.9 0 9 8.5 10/01/2006 07:20:00 7.4 0.7 9.5 5.7 7.3 0.7 9.5 5.7 7.5 0.8 9.5 5.7 156 5 163 165 8.9 0.2 9 8.5 10/01/2006 07:30:00 7.2 0.8 9.9 5.7 7.1 0.7 9.5 5.3 7.2 0.7 9.9 5.7 160 8 153 165 8.9 0.3 9 8.5 10/01/2006 07:40:00 9.5 1 12.2 7.6 9.4 1 12.2 7.2 9.5 0.9 12.2 7.6 161 7 163 165 8.9 0.2 9.3 8.3 10/01/2006 07:50:00 10.4 1.2 13.3 6.8 10.2 1.1 13 6.5 10.4 1.1 13.3 6.8 162 11 168 165 8.8 0.2 9 8.3 10/01/2006 08:00:00 13.2 1.1 16.1 9.9 13 1.1 15.6 10.3 13.1 1.2 16.1 9.9 167 13 178 165 8.7 0.1 9.3 8.3 10/01/2006 08:10:00 13.8 1.1 16.4 10.7 13.7 1 16.4 10.7 13.7 1.1 16.4 11.1 164 8 152 165 8.6 0 8.8 8.3 10/01/2006 08:20:00 13.2 0.7 15.3 11.5 13 0.6 14.9 11.5 13.2 0.7 15.3 11.5 168 14 167 165 8.7 0 9 8.3 10/01/2006 08:30:00 12.6 0.8 14.5 9.9 12.4 0.8 14.1 10.3 12.8 0.8 14.5 10.3 164 13 165 165 8.7 0 9 8.3 10/01/2006 08:40:00 10.4 1 12.2 8.4 10.3 1 12.2 8.4 10.6 1 12.6 8.8 166 12 162 165 8.8 0 9 8.3 10/01/2006 08:50:00 9.2 0.9 11.5 7.2 9 0.8 11.5 7.2 9.4 1 12.2 7.2 166 4 162 165 8.8 0.2 9 8.3 10/01/2006 09:00:00 10.7 1.2 14.9 7.6 10.5 1.1 14.1 7.6 10.7 1.1 13.7 7.6 162 7 160 165 8.8 0.2 9 8.3 10/01/2006 09:10:00 10.9 1.5 14.1 8 10.8 1.4 13.7 7.6 10.9 1.5 14.1 7.6 161 8 163 165 8.9 0.2 9.3 8.3 10/01/2006 09:20:00 9.5 1.1 11.5 6.8 9.5 1 11.5 6.5 9.5 1.2 11.8 6.5 160 9 173 165 9.5 0.4 10.3 8.5 10/01/2006 09:30:00 10.7 0.9 13 8.4 10.6 0.9 12.6 8.4 10.8 1 13.3 8 166 13 165 165 9.6 0.2 10.1 8.8 10/01/2006 09:40:00 10.8 0.6 12.2 8.8 10.6 0.6 11.8 8.8 11 0.7 13 8.8 166 13 165 165 9.2 0 9.3 8.8 10/01/2006 09:50:00 10.9 0.7 12.6 8.8 10.6 0.6 12.2 8.8 11.1 0.7 12.6 9.1 168 14 164 165 8.9 0 9 8.8 10/01/2006 10:00:00 10.7 0.8 13.3 8.4 10.5 0.7 13 8.4 10.9 0.8 13.3 8.8 167 11 165 165 9.4 0.3 9.8 8.8 10/01/2006 10:10:00 10.4 0.5 11.8 8.8 10.1 0.5 11.5 8.8 10.7 0.5 11.8 9.1 167 5 166 165 9.1 0.1 9.6 8.8 10/01/2006 10:20:00 10.7 1 13 8.4 10.4 1 12.6 8.4 10.9 1 13.3 9.1 166 11 166 165 8.9 0 9.3 8.8 10/01/2006 10:30:00 12.3 0.8 14.5 9.9 12.1 0.8 14.5 9.9 12.4 0.9 15.3 10.3 165 10 166 165 8.7 0.1 9.3 8.5 10/01/2006 10:40:00 11.8 0.7 13.7 9.5 11.6 0.7 13.3 9.1 11.9 0.8 14.1 9.9 167 5 165 165 8.7 0.1 9 8.5 10/01/2006 10:50:00 10 0.7 11.8 8 9.7 0.6 11.1 8 10.1 0.8 12.2 7.6 167 6 171 165 9 0.3 9.8 8.5 10/01/2006 11:00:00 10.2 0.7 11.8 8 10.1 0.6 11.5 8.4 10.3 0.8 12.2 8.4 164 15 162 165 9.6 0.3 10.3 9 10/01/2006 11:10:00 10.7 0.7 13 8.4 10.4 0.7 12.6 8.4 10.7 0.8 13 8.8 167 10 169 165 9.1 0.1 9.6 8.8 10/01/2006 11:20:00 11.1 0.8 13 8.8 10.9 0.8 12.6 8.8 11.2 0.8 13.3 8.8 166 9 163 165 9 0.1 9.3 8.8 10/01/2006 11:30:00 10.1 0.8 12.2 8 9.9 0.7 11.8 8 10.2 0.8 12.2 8 168 5 177 165 9 0 9.6 8.8 10/01/2006 11:40:00 10.4 0.7 11.8 8 10.1 0.7 11.8 8 10.6 0.8 12.2 7.6 166 12 165 165 8.9 0 9 8.8 10/01/2006 11:50:00 11.1 0.8 13 8.8 10.9 0.8 12.6 8.8 11.1 0.9 13 8.8 167 6 167 165 9 0 9.3 8.8 10/01/2006 12:00:00 11.6 0.8 13.3 8.4 11.5 0.8 13.3 8.8 11.7 0.8 14.1 8.8 167 11 169 165 9 0 9.3 8.8 10/01/2006 12:10:00 10.7 1 13 8 10.6 0.9 13 8 10.8 1.2 13.3 7.6 167 11 171 165 9.4 0 9.6 9 10/01/2006 12:20:00 10 0.8 12.2 8 9.9 0.8 11.8 8 10 0.9 11.8 7.6 165 4 165 165 9.4 0 9.6 9 10/01/2006 12:30:00 9.8 0.6 11.1 8 9.7 0.6 11.1 8 9.8 0.8 11.5 7.6 164 8 160 165 9.1 0.1 9.6 8.5 10/01/2006 12:40:00 9.8 1 11.5 6.8 9.7 1 11.8 6.8 9.8 1 12.2 6.5 163 12 163 165 9.3 0 9.6 9 10/01/2006 12:50:00 9.9 0.8 11.8 8 9.9 0.8 11.8 8 10 0.7 11.8 7.6 166 7 164 165 9.6 0 9.8 9.3 10/01/2006 13:00:00 10.5 0.9 12.6 8.8 10.4 0.8 12.2 8.4 10.7 0.9 13 8.8 168 6 172 165 9.6 0 9.6 9.3 10/01/2006 13:10:00 11 0.8 13 8.8 10.8 0.7 12.6 9.1 11 1 13 8 166 10 164 165 9.4 0 9.6 9 10/01/2006 13:20:00 11.5 0.7 13.3 9.1 11.4 0.7 13 9.1 11.6 0.9 13.7 9.1 167 6 165 165 9.5 0.1 9.6 9 10/01/2006 13:30:00 10.7 0.8 12.6 8.4 10.6 0.8 12.2 8.8 10.6 1 13 8 167 9 165 165 9.5 0 9.6 9 10/01/2006 13:40:00 11.1 0.8 13 9.1 10.9 0.8 13 8.8 11.1 0.8 13 8.8 168 5 174 165 9.4 0.1 9.6 9 10/01/2006 13:50:00 10 0.7 11.8 8.4 9.8 0.7 11.8 8.4 10.1 0.8 12.2 8.4 166 11 166 165 9.6 0.1 9.8 9.3 10/01/2006 14:00:00 10.3 0.8 12.2 8.4 10.2 0.8 12.2 8 10.3 1 12.6 8.4 167 6 169 165 9.6 0.1 9.8 9.3 10/01/2006 14:10:00 10.9 0.8 13 9.1 10.6 0.7 13 8.8 11.1 0.8 13.3 9.5 170 4 174 165 9.4 0 9.6 8.8 10/01/2006 14:20:00 11 0.7 13 8.8 10.7 0.6 12.2 8.8 11.2 0.8 13 9.1 170 10 167 165 9.4 0.2 9.6 8.8 10/01/2006 14:30:00 10.5 0.7 12.2 8 10.2 0.6 11.8 8 10.7 0.8 12.6 8.8 173 4 170 165 9.4 0.1 9.6 8.8 10/01/2006 14:40:00 9.6 0.5 11.1 8 9.3 0.5 10.7 8 9.9 0.6 11.5 8.4 173 6 171 165 9.6 0 9.8 9.3 10/01/2006 14:50:00 8.8 0.8 10.3 6.5 8.6 0.8 9.9 6.5 9.1 0.9 10.7 6.8 172 4 174 165 9.5 0 9.6 9.3 10/01/2006 15:00:00 8 0.6 9.5 6.5 7.8 0.5 8.8 6.1 8.2 0.6 9.5 6.1 169 5 173 165 9.5 0 9.6 9.3 10/01/2006 15:10:00 6.5 0.6 8.4 4.9 6.4 0.6 8.4 4.9 6.8 0.6 8.4 5.3 158 5 168 165 9.3 0 9.6 9 10/01/2006 15:20:00 6.5 0.5 7.6 4.6 6.4 0.4 7.2 4.2 6.8 0.5 8 4.6 159 3 157 165 9.2 0 9.6 9 10/01/2006 15:30:00 6.1 0.4 7.2 5.3 6 0.4 6.8 4.9 6.3 0.4 7.6 5.3 160 3 164 165 9.2 0 9.6 9 10/01/2006 15:40:00 6.2 0.2 6.8 5.7 6.1 0.2 6.8 5.3 6.5 0.3 7.2 5.7 158 2 160 165 9.1 0.1 9.6 8.8 10/01/2006 15:50:00 5.7 0.4 6.8 4.6 5.6 0.4 6.8 4.6 6 0.4 7.2 4.9 160 3 157 165 9 0 9.3 8.8 10/01/2006 16:00:00 5.4 0.3 6.1 4.6 5.3 0.2 5.7 4.6 5.6 0.3 6.1 4.6 160 3 161 165 9 0 9.3 8.8 10/01/2006 16:10:00 5.5 0.5 6.5 4.2 5.4 0.5 6.5 4.2 5.6 0.6 6.8 4.2 158 3 153 165 9 0 9.3 8.8 10/01/2006 16:20:00 6 0.3 6.5 4.9 6 0.3 6.5 4.9 6.1 0.4 6.8 4.9 159 2 161 165 8.9 0.1 9 8.5 10/01/2006 16:30:00 5.4 0.2 6.5 4.6 5.4 0.2 6.5 4.9 5.6 0.2 6.1 4.9 156 3 161 165 9 0.1 9.3 8.5 10/01/2006 16:40:00 5.6 0.6 7.2 4.2 5.5 0.5 7.2 4.2 5.8 0.5 7.2 4.6 160 10 165 165 8.9 0.1 9 8.5 10/01/2006 16:50:00 5.9 0.5 7.2 4.9 5.8 0.5 7.2 4.9 5.9 0.5 7.6 4.2 161 9 159 165 8.8 0.1 9 8.5 10/01/2006 17:00:00 5.8 0.4 6.8 4.9 5.8 0.4 6.8 4.9 5.9 0.4 7.2 4.9 155 4 152 165 8.7 0.1 9 8.5 10/01/2006 17:10:00 6.4 0.5 7.6 5.3 6.3 0.4 7.6 5.3 6.6 0.5 8 5.3 155 3 156 165 8.8 0 9 8.5 10/01/2006 17:20:00 7.2 0.5 8.4 6.1 7.2 0.4 8.4 6.1 7.4 0.5 8.8 5.3 153 4 153 165 8.7 0.1 9 8.3 10/01/2006 17:30:00 7.8 0.5 9.1 6.1 7.8 0.5 9.5 6.5 7.8 0.6 9.5 6.5 153 4 147 165 8.5 0.1 8.8 8.3 10/01/2006 17:40:00 8.5 0.7 10.3 6.8 8.5 0.7 10.3 6.8 8.3 0.7 9.9 6.8 146 4 150 165 8.4 0.2 8.8 8 10/01/2006 17:50:00 9.4 0.7 11.5 7.2 9.4 0.7 11.5 7.2 9.2 0.7 11.8 7.6 143 4 142 165 8.7 0.2 9 8.3 10/01/2006 18:00:00 10.7 0.8 12.6 8.8 10.7 0.8 13 8.8 10.5 0.9 13 8 146 4 144 165 8.8 0.2 9 8.5 10/01/2006 18:10:00 11.7 0.6 13 9.9 11.8 0.6 13 9.9 11.4 0.7 13 8.8 145 4 148 165 8.8 0.2 9 8.5 10/01/2006 18:20:00 12.2 0.8 14.1 9.1 12.3 0.9 14.5 9.1 11.9 1 14.1 8.4 144 3 148 165 8.8 0.2 9 8.5 10/01/2006 18:30:00 11.8 0.7 13.3 9.9 11.8 0.7 13.3 9.5 11.4 0.9 13.3 8 145 4 146 165 8.8 0.2 9 8.5 10/01/2006 18:40:00 12.4 0.8 14.5 10.3 12.5 0.8 14.5 9.9 12.2 0.9 14.1 9.9 144 4 135 165 8.8 0.2 9 8.5 10/01/2006 18:50:00 13 0.8 14.9 10.7 13.1 0.8 15.3 10.7 12.7 0.8 14.9 10.7 144 5 144 165 8.7 0.1 9 8.3 10/01/2006 19:00:00 12.8 0.9 14.9 9.9 13 0.9 14.9 10.3 12.7 1 14.9 10.3 142 5 145 165 8.7 0 9 8.3 10/01/2006 19:10:00 11.6 0.8 13.7 8.8 11.8 0.8 13.7 9.1 11.3 0.9 13.7 9.1 143 5 145 165 8.7 0 8.8 8.3 10/01/2006 19:20:00 10.3 0.6 12.2 8.4 10.4 0.6 12.2 8.8 10 0.7 12.2 8 143 5 147 165 8.7 0 9 8.3 10/01/2006 19:30:00 9.9 0.5 11.5 8.4 10 0.5 11.1 8.8 9.6 0.7 11.5 7.2 145 4 145 165 8.7 0 9 8.3 10/01/2006 19:40:00 9.8 0.6 11.5 8.4 9.9 0.6 11.5 8 9.6 0.6 11.1 6.8 145 3 147 165 8.8 0 9 8.5 10/01/2006 19:50:00 10.3 0.5 11.5 8.4 10.4 0.5 11.5 8.8 10 0.7 11.8 7.6 144 3 145 165 8.9 0 9 8.5 10/01/2006 20:00:00 10.4 0.6 11.8 8.8 10.4 0.6 11.8 8.8 10.1 0.7 11.5 8.4 147 3 152 165 8.9 0 9 8.5 10/01/2006 20:10:00 10.2 0.6 11.1 8.4 10.3 0.6 11.5 8.4 9.8 0.7 11.1 7.6 146 4 143 165 8.9 0 9 8.5 10/01/2006 20:20:00 11.3 1.2 14.1 8.4 11.3 1.2 13.7 8.4 11 1.2 13.7 7.6 145 4 147 165 8.9 0 9 8.5 10/01/2006 20:30:00 12.1 0.6 13.7 10.7 12.2 0.6 13.7 10.7 11.7 0.8 13.7 9.1 145 3 145 165 9 0 9 8.5 10/01/2006 20:40:00 11.9 0.7 13.3 9.9 11.9 0.7 13.3 9.1 11.6 0.9 13.3 8.8 144 3 145 165 9 0.1 9 8.5 10/01/2006 20:50:00 11 0.6 12.2 9.1 11.1 0.6 12.6 9.5 10.6 0.8 12.6 8 145 3 142 165 9 0.1 9.3 8.5 10/01/2006 21:00:00 10.6 0.7 12.2 8.4 10.7 0.7 12.2 8.8 10.3 0.8 12.6 8 145 4 147 165 9 0.1 9.3 8.5 10/01/2006 21:10:00 10.6 0.7 12.6 8.8 10.6 0.7 12.6 8.4 10.2 0.8 12.2 7.2 144 4 143 165 9 0.1 9.3 8.5 10/01/2006 21:20:00 11 0.6 12.6 9.1 11 0.7 12.6 9.1 10.7 0.8 12.2 8.4 145 4 145 165 9 0.1 9.3 8.5 10/01/2006 21:30:00 10.4 0.6 11.8 8.8 10.5 0.6 12.2 8.8 10 0.6 11.8 8.4 146 3 146 165 9 0.1 9.3 8.5 10/01/2006 21:40:00 9.7 0.7 11.1 8 9.8 0.7 11.5 8 9.4 0.7 11.1 7.6 146 4 147 165 9 0.1 9 8.5 10/01/2006 21:50:00 9.2 0.5 10.7 7.6 9.4 0.5 10.7 8 8.9 0.7 10.3 6.5 142 3 145 165 9 0.1 9 8.5 10/01/2006 22:00:00 9.3 0.8 11.1 6.8 9.4 0.8 11.1 6.8 9.3 0.9 11.5 6.8 142 5 136 165 9 0.1 9.3 8.5 10/01/2006 22:10:00 8.2 0.8 10.3 6.1 8.2 0.8 9.9 6.5 8 1 10.7 5.7 143 5 143 165 9 0.2 9.3 8.5 10/01/2006 22:20:00 7.8 0.6 9.5 6.5 7.8 0.6 9.5 6.5 7.7 0.7 9.1 5.7 143 4 140 165 9 0.1 9.3 8.5 10/01/2006 22:30:00 7.2 0.5 8.8 6.1 7.3 0.5 8.8 6.1 7.2 0.6 8.4 6.1 146 3 142 165 9 0.1 9.3 8.5 10/01/2006 22:40:00 6.3 0.4 7.2 5.3 6.3 0.4 7.6 5.3 6.4 0.5 7.6 5.3 148 4 147 165 9 0.1 9.3 8.5 10/01/2006 22:50:00 5.5 0.3 6.5 4.6 5.4 0.3 6.1 4.6 5.6 0.4 6.5 4.6 148 4 152 165 9 0.1 9.3 8.5 10/01/2006 23:00:00 5.7 0.5 7.2 4.2 5.6 0.5 6.8 4.6 6 0.5 7.2 4.6 155 3 157 165 9 0.1 9 8.5 10/01/2006 23:10:00 5.2 0.5 6.5 4.2 5.1 0.5 6.5 4.2 5.5 0.5 7.2 4.6 152 5 150 165 9 0.1 9.3 8.5 10/01/2006 23:20:00 5.6 0.8 7.6 3.8 5.5 0.8 7.6 3.8 5.8 0.8 7.2 4.2 149 3 146 165 9 0.1 9.3 8.5 10/01/2006 23:30:00 4.4 0.5 5.7 3.4 4.3 0.5 5.3 3.4 4.6 0.4 5.7 3.8 158 4 164 165 9 0.1 9.3 8.5 10/01/2006 23:40:00 4.5 0.4 5.3 3.4 4.4 0.4 4.9 3 4.8 0.3 5.3 3.8 154 5 149 165 9 0 9 8.5 10/01/2006 23:50:00 5.4 0.7 7.2 3.8 5.3 0.6 7.6 3.8 5.6 0.6 6.8 3.8 157 5 155 165 9 0 9.3 8.5 10/02/2006 00:00:00 5.3 0.5 6.5 3.8 5.2 0.5 6.5 3.8 5.4 0.5 6.8 4.2 154 6 152 165 9 0 9.6 8.5 10/02/2006 00:10:00 5.3 0.6 7.2 3.8 5.2 0.6 6.8 3.8 5.4 0.5 6.5 4.2 155 6 157 165 9 0 9.3 8.5 10/02/2006 00:20:00 6 0.8 8.4 4.2 5.9 0.7 8 4.2 6.2 0.7 8.4 4.2 158 6 164 165 9 0 9.3 8.5 10/02/2006 00:30:00 6.9 0.8 9.1 4.9 6.8 0.8 9.1 4.9 7 0.7 9.1 5.3 162 8 167 165 9 0 9.3 8.5 10/02/2006 00:40:00 8.7 0.6 9.9 6.8 8.4 0.5 9.5 6.8 8.6 0.6 11.1 7.2 167 11 172 165 9 0.1 9.3 8.5 10/02/2006 00:50:00 9.1 0.9 10.7 7.2 8.8 0.8 10.3 6.8 9.1 0.8 11.1 7.2 167 4 165 165 9 0.1 9.3 8.5 10/02/2006 01:00:00 8.8 0.7 10.3 6.8 8.5 0.6 9.9 6.5 8.8 0.7 10.7 6.5 164 8 165 165 9 0 9.3 8.5 10/02/2006 01:10:00 9.6 0.9 11.8 6.5 9.4 0.9 11.1 6.5 9.6 1 11.5 6.8 166 11 163 165 9 0.1 9.3 8.5 10/02/2006 01:20:00 8.6 0.9 10.7 6.5 8.5 0.8 10.3 6.5 8.7 0.9 11.5 6.5 163 4 168 165 9.1 0 9.3 8.5 10/02/2006 01:30:00 8.9 0.6 10.7 6.8 8.6 0.6 10.3 6.8 8.9 0.7 10.7 6.5 165 13 231 165 9.1 0 9.3 8.5 10/02/2006 01:40:00 8.2 0.6 9.5 6.1 8 0.6 9.1 6.1 8.3 0.6 9.5 6.1 167 13 165 165 9.1 0 9.3 8.5 10/02/2006 01:50:00 6.5 0.7 8 4.6 6.3 0.6 7.6 4.6 6.5 0.8 8.8 4.6 168 5 165 165 9.1 0.1 9.3 8.5 10/02/2006 02:00:00 7.2 0.5 8.4 5.3 6.8 0.5 8 4.9 7.2 0.6 8.4 5.7 171 5 179 165 9.1 0.1 9.3 8.5 10/02/2006 02:10:00 6.8 0.7 8.4 4.9 6.5 0.7 8 4.9 6.7 0.7 8 4.6 166 9 170 165 9.1 0.1 9.3 8.5 10/02/2006 02:20:00 6 0.5 7.2 4.6 5.7 0.5 6.8 4.6 6.1 0.4 7.2 4.9 167 13 166 165 9.1 0.1 9.3 8.5 10/02/2006 02:30:00 5.8 0.4 6.8 4.9 5.5 0.4 6.5 4.9 5.9 0.4 6.8 4.9 164 8 167 165 9.1 0.1 9.3 8.5 10/02/2006 02:40:00 5 0.5 6.5 3.8 4.7 0.4 5.7 3.8 5.1 0.4 6.5 3.8 171 6 177 165 9 0.1 9.3 8.5 10/02/2006 02:50:00 5.5 0.5 6.8 3.8 5.2 0.5 6.5 3.8 5.5 0.5 6.8 4.2 180 4 183 165 9 0.1 9 8.5 10/02/2006 03:00:00 5.6 0.4 6.5 4.6 5.4 0.4 6.1 4.6 5.8 0.4 6.8 4.6 181 4 186 165 9 0 9 8.5 10/02/2006 03:10:00 6.4 0.3 7.2 5.3 6.2 0.3 6.8 4.9 6.7 0.4 7.6 5.3 179 3 178 165 8.9 0 9 8.8 10/02/2006 03:20:00 5.2 0.5 6.5 4.2 5 0.5 6.1 4.2 5.4 0.4 6.8 4.2 176 3 175 165 8.9 0 9 8.5 10/02/2006 03:30:00 5.1 0.5 6.5 3.8 4.8 0.4 6.1 3.8 5.2 0.4 6.1 4.2 176 3 185 165 8.8 0 9 8.5 10/02/2006 03:40:00 5.5 0.5 6.5 3.8 5.1 0.5 6.1 3.8 5.6 0.5 6.5 4.2 173 6 180 165 8.7 0 9 8.5 10/02/2006 03:50:00 5 0.3 6.1 4.2 4.8 0.3 5.7 4.2 5.1 0.5 6.1 3.8 170 5 168 165 8.8 0 9 8.5 10/02/2006 04:00:00 5.1 0.5 6.5 3.8 4.9 0.5 6.1 3.8 5.3 0.5 6.5 3.8 170 6 170 165 8.8 0 9.3 8.5 10/02/2006 04:10:00 4.9 0.4 5.7 3.8 4.7 0.4 5.3 3.8 5 0.4 5.7 3.8 177 4 167 165 8.7 0 9 8.5 10/02/2006 04:20:00 4.6 0.3 5.3 3.8 4.5 0.4 5.3 3.4 4.8 0.4 5.7 3.4 184 4 183 165 8.7 0 9 8.5 10/02/2006 04:30:00 4.6 0.5 5.7 3.4 4.3 0.5 5.3 3 4.8 0.5 5.7 3 176 4 181 165 8.7 0 9 8.5 10/02/2006 04:40:00 3.6 0.6 4.9 2.3 3.4 0.5 4.6 2.3 3.7 0.5 4.9 2.3 178 8 176 165 8.7 0 9 8.5 10/02/2006 04:50:00 2.9 0.8 4.6 1.1 2.8 0.8 4.2 0.7 3.1 0.8 4.6 1.5 183 9 180 165 8.7 0 8.8 8.5 10/02/2006 05:00:00 4.7 0.5 5.7 3.4 4.4 0.4 5.3 3.4 4.9 0.4 5.7 3.8 173 4 171 165 8.7 0 9 8.5 10/02/2006 05:10:00 5 0.5 6.5 4.2 4.7 0.5 6.1 3.8 5.1 0.4 6.5 4.6 172 4 175 165 8.7 0 9 8.5 10/02/2006 05:20:00 6.9 0.6 8.4 5.7 6.5 0.6 8 5.3 7 0.6 8.8 5.7 173 4 173 165 8.7 0 9 8.5 10/02/2006 05:30:00 6.9 0.6 7.6 4.9 6.5 0.5 7.6 4.9 6.9 0.7 8 4.9 174 5 173 165 8.7 0 9 8.5 10/02/2006 05:40:00 6.6 0.7 8 4.9 6.3 0.6 7.6 4.6 6.6 0.6 8.4 4.9 175 6 177 165 8.7 0 9 8.5 10/02/2006 05:50:00 6.5 0.7 7.6 4.6 6.2 0.7 7.6 4.6 6.6 0.8 8 4.2 178 5 176 165 8.7 0 9 8.5 10/02/2006 06:00:00 5.8 0.5 6.8 4.6 5.5 0.5 6.5 4.2 5.9 0.6 7.6 4.6 180 4 180 165 8.7 0 9 8.5 10/02/2006 06:10:00 5.2 0.4 6.1 4.2 5 0.4 6.1 4.2 5.2 0.4 6.1 4.2 185 3 186 165 8.7 0 8.8 8.3 10/02/2006 06:20:00 4.5 0.6 5.7 3 4.4 0.6 5.3 2.6 4.5 0.6 6.1 3 181 6 186 165 8.6 0.1 8.8 8.3 10/02/2006 06:30:00 5.1 0.9 6.8 2.3 5 0.9 6.8 2.3 5.3 1 6.8 2.6 191 6 203 165 8.6 0 8.8 8.3 10/02/2006 06:40:00 5.6 0.4 6.8 4.2 5.6 0.4 6.8 4.2 5.7 0.5 6.8 4.2 200 3 205 165 8.7 0 9 8.5 10/02/2006 06:50:00 5.6 0.4 6.5 4.6 5.6 0.4 6.5 4.6 5.8 0.5 6.8 4.2 199 6 206 165 8.8 0 9 8.5 10/02/2006 07:00:00 5.1 0.4 5.7 3.8 4.9 0.4 5.7 3.8 5.2 0.4 6.1 4.2 194 4 196 165 8.8 0 9 8.5 10/02/2006 07:10:00 5.1 0.3 5.7 4.6 5 0.3 5.7 4.2 5.3 0.4 6.1 3.8 193 5 196 165 8.7 0 9 8.3 10/02/2006 07:20:00 5.7 0.7 7.6 4.2 5.6 0.6 7.2 4.2 6.3 0.6 8 4.9 190 2 191 165 8.8 0 9 8.5 10/02/2006 07:30:00 6.3 0.4 7.6 5.3 6.2 0.4 7.2 5.3 6.4 0.4 7.6 5.3 188 2 191 165 8.9 0 9 8.5 10/02/2006 07:40:00 6.1 0.4 6.8 4.9 5.9 0.4 6.8 4.9 6.3 0.4 7.2 5.3 184 2 181 165 8.9 0 9 8.5 10/02/2006 07:50:00 5.7 0.5 6.5 4.6 5.4 0.5 6.5 4.2 5.7 0.5 7.2 4.9 176 8 186 165 8.9 0 9 8.5 10/02/2006 08:00:00 5.4 0.3 6.1 4.6 5.1 0.3 5.7 4.2 5.4 0.3 6.1 4.6 165 10 167 165 8.7 0 9 8.5 10/02/2006 08:10:00 5.4 0.4 6.5 4.6 5.1 0.4 5.7 4.2 5.5 0.5 6.5 4.2 169 7 177 165 8.8 0 9 8.5 10/02/2006 08:20:00 5.1 0.4 6.8 4.2 4.9 0.4 6.5 4.2 5.2 0.5 6.1 3.8 176 6 181 165 8.9 0 9 8.5 10/02/2006 08:30:00 4.5 0.5 5.7 3.4 4.3 0.5 5.3 3 4.6 0.5 5.7 3.4 179 5 182 165 8.9 0 9 8.8 10/02/2006 08:40:00 4.5 0.9 6.8 2.6 4.3 0.8 6.8 2.6 4.5 0.8 7.2 3 184 9 195 165 8.9 0 9 8.5 10/02/2006 08:50:00 5 0.7 6.5 3 4.8 0.7 6.5 3.4 5.1 0.7 6.8 3.4 188 9 200 165 9 0 9.3 8.8 10/02/2006 09:00:00 3.4 0.5 4.6 1.9 3.2 0.5 4.2 1.5 3.6 0.5 4.6 1.9 181 8 187 165 9.2 0 9.3 8.8 10/02/2006 09:10:00 3.1 0.7 4.6 1.5 3 0.7 4.2 1.5 3.3 0.6 4.9 1.9 186 11 198 165 9.2 0 9.3 8.8 10/02/2006 09:20:00 3.5 0.7 4.9 1.9 3.4 0.7 4.9 1.9 3.6 0.6 5.3 2.3 188 9 185 165 9.2 0 9.3 8.8 10/02/2006 09:30:00 3.9 0.7 5.7 2.3 3.8 0.8 5.7 1.9 3.8 0.7 5.7 1.9 199 9 206 165 9.2 0 9.6 8.8 10/02/2006 09:40:00 3 1 5.7 0.7 2.8 1 5.3 0.4 3.1 1 5.7 0.7 185 17 177 165 9.2 0 9.6 8.8 10/02/2006 09:50:00 3.3 1.2 5.3 0.7 3.1 1.1 4.9 0.4 3.5 1.1 6.1 1.5 184 17 191 165 9.2 0.2 9.6 8.8 10/02/2006 10:00:00 1.8 1.1 4.2 0.4 1.7 1.1 4.6 0.4 2.1 0.8 4.2 0.4 185 17 204 165 9.7 0.3 10.3 8.8 10/02/2006 10:10:00 3.7 0.9 6.5 1.5 3.5 0.9 6.5 1.1 3.9 1 6.5 1.5 175 15 194 165 10.3 0 10.6 9.8 10/02/2006 10:20:00 5.1 0.6 6.5 3.4 4.8 0.6 6.1 3.4 5.1 0.6 6.5 3.4 174 9 173 165 10.4 0.1 10.9 10.3 10/02/2006 10:30:00 5.1 0.5 6.5 3.8 4.9 0.5 6.5 3.8 5.4 0.5 6.8 4.2 173 7 181 165 10.2 0 10.6 10.1 10/02/2006 10:40:00 4.8 0.7 6.5 3 4.6 0.7 6.1 3 4.8 0.6 6.8 3 174 12 173 165 10.3 0.1 10.9 9.8 10/02/2006 10:50:00 4.3 0.8 6.1 1.9 4.1 0.8 6.1 1.9 4.5 0.6 6.5 3 166 12 165 165 10.5 0.2 10.9 9.8 10/02/2006 11:00:00 4.8 1.2 8 2.3 4.7 1.2 7.6 2.3 5.2 1 7.6 2.6 144 12 133 165 10.1 0.1 10.6 9.6 10/02/2006 11:10:00 5.7 0.5 7.2 4.2 5.5 0.5 6.8 3.8 5.9 0.4 7.2 4.9 159 11 163 165 9.8 0.1 10.3 9.3 10/02/2006 11:20:00 5.5 0.8 6.8 3.8 5.4 0.7 6.5 3.4 5.8 0.8 7.2 3.8 163 8 164 165 9.9 0 10.3 9.6 10/02/2006 11:30:00 5.6 0.6 6.8 3.8 5.5 0.5 6.8 4.2 5.9 0.5 7.2 4.6 164 7 165 165 10.6 0.5 11.4 9.6 10/02/2006 11:40:00 7.1 0.8 9.1 5.3 6.9 0.8 8.8 4.9 7.5 0.8 9.5 5.7 164 8 160 165 10.7 0.4 11.7 10.1 10/02/2006 11:50:00 8.9 0.8 10.7 6.8 8.5 0.7 10.3 6.5 9 0.7 10.7 7.2 167 13 165 165 10 0 10.3 9.6 10/02/2006 12:00:00 7.5 1 9.5 4.9 7.1 1 8.8 4.6 7.5 1 9.9 5.3 167 8 164 165 9.8 0.1 10.1 9.3 10/02/2006 12:10:00 7 0.8 8.8 4.6 6.8 0.7 8.4 4.9 7.1 0.7 8.4 5.3 162 6 181 165 9.8 0.1 10.3 9.3 10/02/2006 12:20:00 6.7 0.8 8.8 4.6 6.5 0.7 8 4.9 6.9 0.7 8.8 4.9 165 15 166 165 10.5 0.3 11.1 9.6 10/02/2006 12:30:00 6.8 0.7 8.4 4.9 6.7 0.6 8.4 4.9 7.1 0.7 9.1 5.7 158 11 158 165 11.3 0.1 11.7 10.9 10/02/2006 12:40:00 7.1 0.8 8.8 4.2 6.9 0.7 8.4 4.6 7.5 0.7 9.1 5.7 162 12 168 165 10.9 0.2 11.7 10.6 10/02/2006 12:50:00 7.3 0.6 9.1 5.7 7 0.6 9.1 5.3 7.4 0.6 8.8 6.1 164 15 185 165 10.5 0 10.9 10.1 10/02/2006 13:00:00 7.4 1.5 10.7 4.2 7.1 1.4 10.3 3.8 7.6 1.5 10.7 4.9 173 9 174 165 10.3 0.1 10.6 9.6 10/02/2006 13:10:00 10.8 0.9 12.2 8.8 10.4 0.9 11.8 8 10.9 1 13.3 8.8 172 5 175 165 10 0 10.3 9.8 10/02/2006 13:20:00 8.9 1.2 11.5 5.7 8.6 1.2 10.7 5.7 9 1.2 11.5 6.1 178 6 169 165 10 0.1 10.3 9.6 10/02/2006 13:30:00 7.5 0.7 9.5 5.7 7.2 0.6 9.1 5.7 7.6 0.7 9.1 6.1 173 12 165 165 10.2 0.1 10.9 9.8 10/02/2006 13:40:00 7.7 0.8 9.9 5.7 7.4 0.7 9.5 5.7 7.8 0.8 10.3 6.1 172 8 165 165 10.6 0 10.9 10.3 10/02/2006 13:50:00 8.4 0.7 9.9 6.5 8 0.6 9.5 6.5 8.5 0.6 9.9 6.5 174 6 172 165 10 0 10.3 9.6 10/02/2006 14:00:00 8.2 0.8 10.3 6.1 7.9 0.7 9.9 6.1 8.3 0.8 9.9 6.1 178 7 182 165 9.8 0.2 10.1 9.3 10/02/2006 14:10:00 7.8 0.8 9.5 5.7 7.5 0.8 9.1 5.7 7.9 0.8 9.9 5.7 175 8 176 165 9.8 0 10.3 9.3 10/02/2006 14:20:00 7.9 0.8 9.9 5.7 7.6 0.8 9.5 5.3 8.1 0.8 10.3 6.1 173 6 176 165 9.7 0 9.8 9.6 10/02/2006 14:30:00 9.5 0.9 11.5 7.2 9.2 0.8 11.1 6.8 9.6 1 11.5 7.2 174 7 172 165 9.8 0 9.8 9.3 10/02/2006 14:40:00 9 0.7 10.3 6.1 8.6 0.6 9.9 6.1 9.1 0.7 11.1 7.2 173 13 179 165 9.8 0 10.1 9.6 10/02/2006 14:50:00 10 0.8 11.8 6.8 9.6 0.7 11.1 6.5 10.1 0.8 11.8 7.2 175 9 178 165 9.7 0.1 9.8 9 10/02/2006 15:00:00 10 0.8 11.5 8 9.6 0.7 11.1 7.6 10 0.8 11.8 7.6 177 5 179 165 9.5 0 9.6 9.3 10/02/2006 15:10:00 9.1 1 11.1 6.8 8.9 0.9 11.1 6.5 9.3 0.9 12.2 7.2 176 9 188 165 9.4 0 9.6 9.3 10/02/2006 15:20:00 9.8 0.8 11.5 7.6 9.4 0.8 11.1 7.6 10 0.8 12.2 7.6 174 6 177 165 9.2 0 9.3 9 10/02/2006 15:30:00 9.4 1 11.8 7.2 9.2 1 11.5 6.8 9.6 1.1 12.6 6.8 175 6 173 165 9.2 0 9.3 9 10/02/2006 15:40:00 10.8 0.7 12.2 8.4 10.5 0.6 11.8 8.4 10.9 0.8 12.2 8 174 5 178 165 9.2 0 9.3 8.8 10/02/2006 15:50:00 10 0.9 12.2 7.6 9.7 0.8 11.8 7.6 10.1 0.9 12.2 7.2 176 5 178 165 9.2 0 9.3 8.8 10/02/2006 16:00:00 9.6 0.6 11.1 8 9.2 0.6 10.7 7.6 9.8 0.7 11.8 8 175 6 178 165 9.4 0 9.6 9 10/02/2006 16:10:00 11 0.8 12.6 9.1 10.7 0.8 12.6 8.4 11.2 0.9 13 8.4 173 5 176 165 9.2 0 9.6 9 10/02/2006 16:20:00 11.3 0.9 13 8 11 0.8 13 8 11.3 1 13.3 8.8 177 6 177 165 9.1 0.1 9.3 8.5 10/02/2006 16:30:00 11.5 0.9 13.3 8.8 11.2 0.8 13 8.8 11.7 1 13.7 8.8 173 10 172 165 9 0.1 9.3 8.5 10/02/2006 16:40:00 12.4 0.8 13.7 9.9 12 0.8 13.3 9.5 12.5 0.9 14.5 10.3 169 8 172 165 8.9 0 9.3 8.5 10/02/2006 16:50:00 12.2 0.6 14.1 10.3 11.9 0.6 13.7 10.3 12.4 0.9 14.5 9.1 169 11 169 165 8.7 0 9 8.5 10/02/2006 17:00:00 12.6 0.9 14.5 9.9 12.3 0.8 13.7 9.5 12.8 1 14.5 9.1 169 5 170 165 8.7 0 9 8.5 10/02/2006 17:10:00 12.2 0.7 13.7 9.5 11.8 0.6 13.3 9.9 12.4 0.8 14.1 9.9 168 10 153 165 8.5 0.1 8.8 8.3 10/02/2006 17:20:00 11.6 0.7 13 9.5 11.3 0.6 13 9.1 11.6 0.9 13.7 9.1 167 16 166 165 8.5 0.1 8.8 8.3 10/02/2006 17:30:00 11.1 0.7 12.6 9.1 10.8 0.6 12.6 8.8 11.1 0.8 12.6 9.1 166 11 171 165 8.5 0.1 8.8 8.3 10/02/2006 17:40:00 10.9 0.6 13 9.1 10.6 0.6 12.2 8.8 11.2 0.8 13 9.1 169 4 172 165 8.6 0.1 9 8.3 10/02/2006 17:50:00 12.4 0.6 13.7 10.7 12 0.6 13.3 10.3 12.8 0.7 14.5 10.7 169 5 187 165 8.7 0 9 8.3 10/02/2006 18:00:00 11.5 0.8 13 8.8 11.1 0.7 12.6 9.1 11.8 0.9 13.3 9.5 169 11 173 165 8.4 0.2 8.8 8 10/02/2006 18:10:00 10.5 0.7 12.6 8.4 10.3 0.7 12.2 8 10.7 0.7 12.6 8.8 167 7 175 165 8.1 0.1 8.5 7.8 10/02/2006 18:20:00 10.6 0.7 12.6 8.4 10.5 0.7 12.6 8.4 10.8 0.7 12.6 9.1 166 4 163 165 8 0.1 8.3 7.5 10/02/2006 18:30:00 10.1 0.8 12.2 8.4 10 0.7 11.8 8.4 10.3 0.7 12.2 8.4 166 15 165 165 7.9 0.2 8.3 7.5 10/02/2006 18:40:00 10.6 0.8 12.6 9.1 10.3 0.7 12.2 8.8 10.7 0.9 12.6 8.8 167 18 173 165 8 0.1 8.3 7.5 10/02/2006 18:50:00 8.5 1 10.7 6.5 8.4 0.9 10.3 6.5 8.6 1.1 11.1 6.5 160 5 164 165 8 0.1 8.3 7.5 10/02/2006 19:00:00 8.6 0.6 10.3 6.5 8.5 0.6 10.3 6.5 8.9 0.6 10.3 6.8 156 4 161 165 8 0 8.3 7.8 10/02/2006 19:10:00 9.7 1 11.8 8 9.7 1 11.8 8 9.8 1 12.2 7.6 150 6 150 165 8.1 0 8.5 7.8 10/02/2006 19:20:00 11.4 0.6 12.6 9.1 11.4 0.5 12.6 9.5 11.2 0.7 12.6 8.8 150 3 150 165 8.3 0.2 8.5 7.5 10/02/2006 19:30:00 11.6 0.6 13 9.9 11.6 0.5 13 9.9 11.3 0.7 13 8.8 150 3 152 165 8.4 0 8.5 8 10/02/2006 19:40:00 12.3 0.8 14.5 10.3 12.4 0.7 14.5 10.3 12.2 0.8 14.5 9.5 150 3 151 165 8.4 0.2 8.8 8 10/02/2006 19:50:00 13.4 0.6 14.9 10.7 13.4 0.6 14.9 11.1 13.3 0.8 14.9 11.1 151 3 150 165 8.4 0.3 8.8 7.8 10/02/2006 20:00:00 13.5 0.6 15.6 11.8 13.5 0.6 15.3 11.8 13.4 0.8 15.3 10.7 152 2 152 165 8.4 0.3 8.8 7.8 10/02/2006 20:10:00 13.5 0.7 15.3 11.5 13.5 0.7 15.3 11.5 13.5 0.8 15.3 11.5 152 2 151 165 8.5 0.2 8.8 8 10/02/2006 20:20:00 13.4 0.7 14.9 11.5 13.3 0.7 14.9 11.5 13.2 0.9 15.3 10.3 150 3 151 165 8.5 0.3 8.8 8 10/02/2006 20:30:00 14 0.6 15.3 12.2 14 0.6 16.1 12.2 13.6 0.8 15.3 11.1 149 3 153 165 8.5 0.2 8.8 8 10/02/2006 20:40:00 13.3 0.8 15.3 11.1 13.4 0.8 15.3 11.1 13 1 15.3 10.3 148 3 151 165 8.5 0.2 8.8 7.8 10/02/2006 20:50:00 13.6 0.8 15.6 11.8 13.6 0.8 15.6 11.8 13.3 0.9 15.6 10.7 148 3 148 165 8.6 0.2 9 8.3 10/02/2006 21:00:00 14 0.7 15.6 11.8 14 0.7 15.6 11.8 13.6 0.8 15.3 11.1 151 3 152 165 8.7 0.1 9 8.3 10/02/2006 21:10:00 14.6 0.9 16.8 12.6 14.7 0.9 16.8 12.6 14.3 0.9 16.4 11.8 148 3 145 165 8.8 0.1 9 8.5 10/02/2006 21:20:00 15.4 0.9 17.9 13 15.5 0.9 17.9 13 15.1 1 17.6 11.5 148 3 150 165 8.9 0.1 9 8.3 10/02/2006 21:30:00 15.8 0.9 17.9 13.3 16 0.9 17.9 13.7 15.5 1.2 17.9 12.2 148 4 150 165 8.8 0.2 9 8.5 10/02/2006 21:40:00 15.7 0.8 17.9 13.3 15.8 0.8 17.9 13.3 15.2 1.1 18.3 11.1 149 3 152 165 8.9 0.2 9 8.5 10/02/2006 21:50:00 16.1 1 18.3 13.7 16.1 0.9 18.3 13.7 15.5 1.1 18.3 12.2 150 4 151 165 8.9 0.3 9 8.5 10/02/2006 22:00:00 17.3 1 19.1 14.5 17.3 1 19.1 14.9 16.8 1.3 19.5 10.7 149 3 151 165 8.9 0.3 9.3 8.5 10/02/2006 22:10:00 18.7 0.8 21 16.8 18.7 0.8 20.6 16.8 18.3 0.9 20.6 15.3 150 3 155 165 8.9 0.3 9.3 8.5 10/02/2006 22:20:00 19.6 0.9 21.4 17.2 19.6 0.8 21.4 17.2 18.8 1.2 21.4 15.3 150 3 153 165 9 0.3 9.3 8.5 10/02/2006 22:30:00 19.6 0.8 21.8 17.2 19.6 0.8 21.4 17.2 19 1.3 21.8 14.5 150 3 153 165 9 0.2 9.3 8.5 10/02/2006 22:40:00 22.9 1.8 25.6 18.3 22.8 1.8 25.6 18.3 22.7 2.1 26 15.6 152 3 152 165 9.1 0.2 9.3 8.5 10/02/2006 22:50:00 22.7 1.5 25.2 19.5 22.6 1.4 25.2 19.5 22.6 1.6 26 19.1 153 2 154 165 9 0.2 9.3 8.5 10/02/2006 23:00:00 17.9 1.4 21.4 14.1 17.8 1.4 21 14.1 17.7 1.4 21.4 13.7 150 2 151 165 9.1 0.2 9.6 8.5 10/02/2006 23:10:00 14.8 0.8 16.8 12.6 14.9 0.8 16.8 12.6 14.5 1 16.8 11.1 147 4 154 165 9.2 0.1 9.6 8.5 10/02/2006 23:20:00 15.5 0.8 17.2 13.3 15.5 0.7 17.6 13.3 15.3 0.9 17.6 12.2 147 3 150 165 9.2 0.1 9.6 8.8 10/02/2006 23:30:00 15.6 0.6 17.9 13.7 15.7 0.7 17.9 13.7 15.3 0.8 17.2 11.8 147 3 151 165 9.2 0.2 9.6 8.8 10/02/2006 23:40:00 15 0.8 17.6 13 15 0.8 17.9 13 14.6 0.9 16.8 12.2 147 3 146 165 9.2 0.1 9.6 8.8 10/02/2006 23:50:00 15.1 0.7 17.2 13 15.1 0.7 17.2 13 14.9 0.8 17.2 11.8 149 3 150 165 9.3 0.2 9.6 8.8 10/03/2006 00:00:00 14.6 0.8 16.4 12.2 14.6 0.8 16.4 12.2 14.3 0.8 16.4 11.5 149 3 151 165 9.4 0.2 9.6 9 10/03/2006 00:10:00 14.5 0.9 16.8 11.8 14.5 0.9 16.8 12.2 14.3 1.1 16.8 11.1 148 3 149 165 9.4 0.2 9.6 9 10/03/2006 00:20:00 14.6 0.9 17.2 12.2 14.7 0.9 16.8 12.6 14.4 0.8 16.8 12.2 147 3 147 165 9.4 0.2 9.6 9 10/03/2006 00:30:00 13.1 0.8 15.3 10.3 13.1 0.9 15.3 10.3 12.8 1.1 15.6 8.4 147 3 145 165 9.4 0.2 9.6 9 10/03/2006 00:40:00 11.9 0.7 14.1 10.3 12 0.7 13.7 10.3 11.5 0.9 13.7 8.4 146 3 147 165 9.4 0.2 9.6 9 10/03/2006 00:50:00 10.9 0.6 12.2 9.1 10.9 0.6 12.6 9.1 10.7 0.8 12.6 8.8 147 3 150 165 9.4 0.2 9.6 9 10/03/2006 01:00:00 9.4 0.4 10.7 8.4 9.4 0.5 10.7 8 9.2 0.5 10.3 7.6 149 3 148 165 9.4 0.2 9.6 9 10/03/2006 01:10:00 9 0.7 10.3 7.2 9 0.7 10.3 7.2 9 0.7 10.7 6.8 149 3 153 165 9.4 0.2 9.6 9 10/03/2006 01:20:00 8.7 0.6 10.3 6.8 8.5 0.6 10.3 6.8 8.8 0.7 10.3 6.8 154 4 156 165 9.5 0.2 9.8 9 10/03/2006 01:30:00 8.4 1 11.1 5.3 8.2 1 11.1 5.3 8.4 1 11.1 4.9 160 12 172 165 9.6 0.2 10.1 9 10/03/2006 01:40:00 8.4 1.2 11.5 5.7 8.2 1.1 11.1 5.3 8.5 1.1 11.1 6.5 160 11 157 165 9.6 0.1 10.1 9.3 10/03/2006 01:50:00 9.2 0.7 11.5 7.6 8.9 0.7 11.1 7.2 9.3 0.8 11.5 7.2 160 4 163 165 9.8 0 10.3 9.3 10/03/2006 02:00:00 8.2 1.3 10.7 4.9 8 1.2 10.3 4.6 8.2 1.4 10.7 4.9 159 4 158 165 9.9 0 10.1 9.6 10/03/2006 02:10:00 5.2 0.7 6.8 3.4 5.1 0.7 6.8 3.4 5.3 0.7 6.8 3.8 156 6 156 165 9.8 0.1 10.3 9.6 10/03/2006 02:20:00 5.5 0.4 6.5 4.2 5.4 0.4 6.5 4.2 5.8 0.4 6.5 4.6 156 7 157 165 9.8 0 10.1 9.3 10/03/2006 02:30:00 6.2 0.8 8.4 4.2 6.1 0.8 8.4 4.2 6.4 0.8 8.4 4.6 159 9 165 165 9.8 0.1 10.3 9.3 10/03/2006 02:40:00 5.4 0.9 7.2 3 5.2 0.9 6.8 3 5.4 0.8 7.6 3.4 167 10 167 165 9.8 0.1 10.1 9.3 10/03/2006 02:50:00 9 2.1 12.2 4.2 8.8 2.1 11.5 3.4 8.8 2.1 11.8 3.8 166 12 155 165 9.7 0.1 10.3 9.3 10/03/2006 03:00:00 10.9 0.7 12.6 8 10.6 0.6 12.2 8 10.9 0.8 12.2 8.4 166 14 165 165 9.8 0.1 10.1 9.3 10/03/2006 03:10:00 11.6 1 14.1 9.1 11.1 0.9 13.3 8.8 11.7 1 14.1 8.8 173 13 176 165 9.7 0.1 9.8 9.3 10/03/2006 03:20:00 13.6 1.1 16.1 10.3 13.1 1.1 15.6 9.9 13.6 1.2 16.1 10.3 171 5 180 165 9.6 0.2 9.8 9 10/03/2006 03:30:00 11 1.4 14.1 7.2 10.7 1.3 14.1 7.2 11 1.5 14.5 7.2 167 17 173 165 9.4 0.2 9.6 9 10/03/2006 03:40:00 9.2 0.9 11.8 7.2 9 0.9 11.1 6.8 9.3 1 11.8 6.8 170 6 162 165 9.2 0.1 9.6 8.8 10/03/2006 03:50:00 9.3 1.2 11.8 6.1 9.1 1.1 11.5 6.8 9.4 1.2 12.2 6.8 174 7 177 165 9.2 0.1 9.6 8.8 10/03/2006 04:00:00 8.8 1.1 12.2 6.1 8.6 1 11.8 5.7 9 1 11.8 6.5 177 10 179 165 9 0.2 9.3 8.5 10/03/2006 04:10:00 9.9 1 13.3 6.8 9.6 0.9 12.6 6.5 10.1 1.1 12.6 6.8 175 7 167 165 9 0.3 9.3 8.5 10/03/2006 04:20:00 10 1.1 13 7.6 9.8 1 12.2 7.2 10.1 1.1 13.3 7.6 177 7 166 165 9 0.3 9.3 8.5 10/03/2006 04:30:00 9.5 1.3 12.6 6.1 9.3 1.3 12.2 6.1 9.6 1.2 12.6 6.5 179 8 169 165 9 0.3 9.3 8.5 10/03/2006 04:40:00 10.6 1 13 7.6 10.2 0.9 12.6 7.6 10.5 1 13 7.6 176 6 175 165 9 0.2 9.3 8.5 10/03/2006 04:50:00 10.9 1.1 13.7 8.4 10.6 1 13 8 11.1 1 13.7 8.4 176 7 175 165 9 0.1 9.3 8.5 10/03/2006 05:00:00 12.4 0.9 14.5 10.3 12 0.8 13.7 9.9 12.5 0.9 15.3 10.3 172 5 175 165 9 0.1 9.3 8.5 10/03/2006 05:10:00 12 0.8 13.7 9.5 11.6 0.8 13.7 9.1 12.1 0.8 13.7 10.3 169 10 170 165 9 0.1 9.3 8.5 10/03/2006 05:20:00 10.7 0.6 12.2 9.1 10.4 0.6 11.8 8.8 10.8 0.7 12.2 8.8 168 3 166 165 9 0.1 9.3 8.5 10/03/2006 05:30:00 9.5 0.7 11.8 7.2 9.1 0.7 11.1 7.2 9.4 0.7 11.5 7.2 174 6 183 165 9 0.1 9.3 8.5 10/03/2006 05:40:00 8.2 0.8 9.9 6.1 8 0.7 9.5 5.7 8.4 0.8 9.9 6.5 173 6 183 165 9 0 9 8.5 10/03/2006 05:50:00 8.1 1.1 10.7 5.3 7.8 1 10.3 5.3 8.2 1.1 10.3 5.7 173 6 165 165 8.9 0 9 8.5 10/03/2006 06:00:00 7.9 0.8 9.5 5.3 7.6 0.8 9.1 5.7 8 0.7 9.5 6.1 172 6 150 165 8.9 0 9 8.3 10/03/2006 06:10:00 7.4 1 9.9 5.3 7.2 1 9.1 4.9 7.5 1 9.9 4.9 175 7 164 165 8.8 0 9 8.5 10/03/2006 06:20:00 6.3 0.9 8.4 4.2 6.1 0.8 8.4 4.2 6.5 1 9.1 4.6 176 12 177 165 8.8 0 9 8.5 10/03/2006 06:30:00 4.9 1 8 3 4.8 1 7.6 2.6 5 0.9 8 3.4 178 9 180 165 8.8 0 9 8.5 10/03/2006 06:40:00 4.8 1 7.2 2.6 4.6 0.9 6.5 2.3 5 0.8 6.8 3 173 7 183 165 8.7 0 9 8.5 10/03/2006 06:50:00 5.4 0.9 8.4 3.4 5.4 0.9 8 3.4 5.6 1 8.8 3.8 170 13 154 165 8.7 0 8.8 8.5 10/03/2006 07:00:00 5.3 1 7.6 2.3 5.1 0.9 7.2 2.3 5.5 1 7.6 3.4 170 13 195 165 8.7 0 8.8 8.5 10/03/2006 07:10:00 5.1 0.8 6.8 3.4 4.9 0.7 6.5 3 5.3 0.8 7.2 3.4 168 9 165 165 8.6 0 8.8 8.5 10/03/2006 07:20:00 5 1 8 1.5 4.9 1 7.2 1.1 5.2 0.9 7.2 2.3 169 15 165 165 8.5 0 8.8 8.3 10/03/2006 07:30:00 6 1.1 9.5 3.4 5.9 1.1 8.8 3 6.2 1.1 9.1 2.6 175 13 180 165 8.5 0 8.8 8.3 10/03/2006 07:40:00 4.9 1 7.2 2.6 4.7 0.9 6.8 2.6 5.2 0.9 7.2 3 173 9 173 165 8.5 0.1 8.5 8.3 10/03/2006 07:50:00 4.6 1.3 7.2 0.4 4.5 1.4 7.2 0.4 4.6 1.2 6.8 1.1 184 17 203 165 8.3 0.1 8.5 8 10/03/2006 08:00:00 5.5 0.8 7.6 3.4 5.6 0.8 8 3.4 5.8 0.8 7.6 3.8 184 12 190 165 8.3 0.1 8.8 7.8 10/03/2006 08:10:00 6.7 0.8 8.4 4.6 6.8 0.8 8.4 4.9 7 1 9.1 4.2 197 6 193 165 8.3 0.1 8.5 8 10/03/2006 08:20:00 7.1 0.8 8.8 4.9 7.1 0.8 8.8 4.9 7.2 0.8 9.1 5.3 192 7 189 165 8.3 0 8.5 7.8 10/03/2006 08:30:00 6.5 1.4 9.9 3.8 6.4 1.3 9.1 3.8 6.7 1.5 9.9 4.2 185 8 184 165 8.3 0.1 8.5 7.8 10/03/2006 08:40:00 5.1 0.6 6.5 3.8 5 0.6 6.5 3.4 5.3 0.6 6.8 3.8 186 8 179 165 8.3 0.1 8.5 7.8 10/03/2006 08:50:00 5.7 0.9 8 3.4 5.8 1 8 3.4 5.8 0.9 8 4.2 196 9 212 165 8.3 0 8.5 7.8 10/03/2006 09:00:00 5.4 0.9 7.6 3.4 5.3 0.8 7.6 3.4 5.5 0.9 8 3 184 7 193 165 8.3 0 8.5 7.8 10/03/2006 09:10:00 5.3 0.6 7.2 3.8 5.2 0.6 6.8 3.4 5.5 0.6 6.8 4.2 186 8 185 165 8.2 0.1 8.5 7.8 10/03/2006 09:20:00 4.6 0.8 7.2 3 4.5 0.8 6.8 2.6 4.8 0.8 6.5 3 188 8 189 165 8.3 0.1 8.5 7.8 10/03/2006 09:30:00 5.3 0.6 6.8 3.8 5.3 0.5 6.5 3.8 5.5 0.6 6.8 3.8 185 7 179 165 8.3 0 8.5 8 10/03/2006 09:40:00 5.3 0.9 7.6 2.3 5.2 0.9 6.8 2.3 5.4 0.8 7.2 3 185 11 182 165 8.3 0.1 8.5 8 10/03/2006 09:50:00 4.8 0.8 6.8 2.3 4.7 0.8 6.5 2.3 4.9 0.7 6.8 3 187 8 185 165 8.4 0 8.5 8 10/03/2006 10:00:00 4.4 0.7 6.1 3 4.4 0.7 6.1 2.6 4.8 0.6 6.5 3.4 194 9 183 165 8.5 0 8.8 8.5 10/03/2006 10:10:00 4 0.8 6.1 1.9 3.9 0.7 5.3 1.5 4.2 0.7 5.7 2.3 186 13 196 165 8.5 0.1 8.8 8 10/03/2006 10:20:00 4.1 0.7 5.7 2.3 4 0.7 5.7 2.3 4.2 0.6 5.3 2.6 181 13 175 165 8.6 0 8.8 8 10/03/2006 10:30:00 4.2 0.5 5.7 2.6 4 0.5 5.7 2.3 4.4 0.5 5.7 3 177 11 198 165 8.6 0 9 8.3 10/03/2006 10:40:00 5.3 1.1 8 3 5.1 1 7.6 3 5.4 1 8 3.4 171 7 180 165 8.7 0.2 9 8.3 10/03/2006 10:50:00 6.8 0.7 8.4 5.3 6.5 0.6 7.6 5.3 7 0.6 8 5.3 170 5 165 165 8.9 0.2 9.3 8.3 10/03/2006 11:00:00 9 1 10.7 6.5 8.6 1 10.3 6.1 9 1.1 11.5 6.5 167 4 170 165 8.9 0.2 9.3 8.5 10/03/2006 11:10:00 8.3 0.8 9.9 6.1 8 0.8 9.5 5.7 8.4 0.8 10.3 6.5 168 6 165 165 8.9 0.2 9 8.5 10/03/2006 11:20:00 9.1 0.5 10.3 7.6 8.8 0.5 9.9 7.6 9.2 0.6 10.7 7.2 168 7 166 165 8.8 0.2 9.3 8.5 10/03/2006 11:30:00 8.1 0.6 9.5 6.5 7.8 0.5 8.8 6.5 8.2 0.6 9.5 6.5 171 4 174 165 9 0 9.6 8.8 10/03/2006 11:40:00 7.1 0.7 8.8 4.9 6.8 0.7 8.8 4.9 7.3 0.7 9.1 5.7 171 12 165 165 8.9 0.1 9 8.5 10/03/2006 11:50:00 4.7 0.8 6.8 2.6 4.6 0.7 6.5 3 5 0.7 6.8 3.4 179 9 187 165 9.1 0.1 9.6 8.5 10/03/2006 12:00:00 3.9 1 6.8 1.5 3.8 1 7.2 1.9 4.2 0.8 6.5 2.3 179 12 174 165 9.2 0 9.6 8.8 10/03/2006 12:10:00 4.8 0.9 8 2.6 4.7 1 8 2.3 5 0.6 6.8 3.4 179 11 204 165 9.4 0 9.6 9.3 10/03/2006 12:20:00 5.3 0.6 6.8 3 5.1 0.6 6.8 3 5.5 0.7 7.2 3.4 176 10 177 165 9.1 0.1 9.6 8.8 10/03/2006 12:30:00 5.7 1.2 8.8 2.3 5.7 1.2 9.1 1.9 5.8 1.1 8.4 3.4 191 12 193 165 9.1 0 9.3 8.8 10/03/2006 12:40:00 7.4 1 9.9 4.9 7.5 1.1 9.5 4.6 7.6 1.1 11.1 5.3 198 8 201 165 9.4 0 9.6 9 10/03/2006 12:50:00 9.1 0.9 11.5 6.5 9.1 0.9 11.5 6.8 9.3 1 11.8 6.5 194 6 192 165 9.4 0 9.6 9.3 10/03/2006 13:00:00 7.6 0.8 9.9 5.3 7.6 0.8 9.5 4.9 7.9 0.9 9.9 5.3 191 8 193 165 9.5 0.1 9.6 9 10/03/2006 13:10:00 7.1 1 10.3 5.3 7 1 10.3 4.9 7.2 0.9 9.9 4.6 184 11 183 165 9.5 0 9.6 9.3 10/03/2006 13:20:00 7.3 1.3 10.3 4.2 7.1 1.3 9.9 4.2 7.5 1.2 11.1 4.6 176 8 172 165 9.2 0.1 9.3 9 10/03/2006 13:30:00 8.1 1 10.7 5.3 7.9 1 10.3 5.3 8.3 1.1 11.1 5.3 176 8 170 165 9 0 9.3 8.8 10/03/2006 13:40:00 6.5 0.7 9.5 4.6 6.3 0.7 8.8 4.6 6.6 0.8 9.5 4.9 175 9 185 165 9.6 0.3 10.3 9 10/03/2006 13:50:00 7 1.1 9.9 4.2 6.9 1.1 9.9 3.8 7.4 1 9.9 4.9 184 9 190 165 9.8 0.1 10.3 9.6 10/03/2006 14:00:00 8.8 1.3 11.8 5.3 8.8 1.3 11.8 5.3 9.1 1.3 12.6 6.1 194 7 194 165 9.6 0 9.8 9.3 10/03/2006 14:10:00 7.4 1.3 11.1 4.2 7.4 1.3 11.1 4.2 7.5 1.1 10.7 4.6 195 9 201 165 10 0.1 10.3 9.6 10/03/2006 14:20:00 8 1.4 11.8 4.6 8 1.3 11.8 4.9 8.1 1.5 11.1 4.6 189 10 187 165 10.2 0 10.6 9.8 10/03/2006 14:30:00 8.2 1.3 11.5 4.6 8.1 1.3 11.5 4.6 8.3 1.3 11.8 4.9 191 9 188 165 10 0 10.6 9.6 10/03/2006 14:40:00 6.4 1.3 9.5 3.4 6.4 1.3 9.9 3.4 6.6 1.3 9.5 3.8 193 11 198 165 10.7 0.4 11.7 9.6 10/03/2006 14:50:00 5.7 1 8.4 3 5.6 0.9 8.4 3 5.9 1 8.8 3.4 184 12 175 165 11.4 0.1 11.9 11.1 10/03/2006 15:00:00 6.7 0.8 9.5 4.6 6.6 0.8 8.8 4.6 6.9 0.9 9.1 4.6 176 8 178 165 11.2 0.1 11.7 10.9 10/03/2006 15:10:00 7 1 9.5 4.6 6.8 1 9.5 4.6 7.2 0.9 9.5 4.6 177 9 183 165 11.2 0 11.7 10.9 10/03/2006 15:20:00 8.1 1.2 11.1 5.3 7.9 1.2 11.1 4.9 8.1 1.1 10.7 5.3 183 11 181 165 11.3 0 11.7 11.1 10/03/2006 15:30:00 8.4 1.2 11.1 5.7 8.2 1.2 11.1 5.7 8.6 1.3 11.5 5.3 183 10 186 165 11.3 0 11.7 11.1 10/03/2006 15:40:00 9.6 1.4 13.7 5.7 9.4 1.4 13.7 5.7 9.8 1.3 13.3 6.8 182 9 191 165 10.9 0.2 11.4 10.6 10/03/2006 15:50:00 8.6 1.5 12.2 4.2 8.5 1.5 11.8 4.9 8.8 1.7 12.6 4.2 182 13 183 165 11.1 0 11.4 10.3 10/03/2006 16:00:00 4.9 1.3 8 1.5 4.8 1.2 7.6 1.9 4.9 1.3 8 2.3 191 17 188 165 11.3 0.1 11.7 11.1 10/03/2006 16:10:00 6 1 8.8 3.4 6 1 8.8 3.8 6.3 1 9.1 3.8 193 15 198 165 11.1 0.1 11.7 10.9 10/03/2006 16:20:00 7.1 1 9.1 4.6 7.1 1 9.5 4.6 7.1 1.1 9.5 4.2 196 9 200 165 10.3 0.3 11.1 9.8 10/03/2006 16:30:00 6.4 1.2 9.1 3 6.3 1.3 9.1 3.4 6.6 1.1 9.9 4.6 190 12 194 165 9.7 0.1 9.8 9 10/03/2006 16:40:00 8.8 1.3 12.2 5.7 8.9 1.3 12.2 5.3 8.9 1.3 12.2 5.7 198 8 179 165 9.5 0.1 9.8 9 10/03/2006 16:50:00 9.1 1.3 12.6 6.5 9.1 1.2 12.6 6.5 9.4 1.3 13 6.1 188 10 184 165 9 0.1 9.3 8.8 10/03/2006 17:00:00 7.7 1.2 10.3 4.9 7.7 1.2 10.7 4.9 7.8 1.3 11.1 4.9 189 9 184 165 8.6 0.1 9 8.5 10/03/2006 17:10:00 9 1 11.8 6.5 8.9 1 11.5 6.5 8.8 1 11.5 6.1 188 10 185 165 8.5 0 8.8 8.3 10/03/2006 17:20:00 7.6 1.4 11.5 4.6 7.6 1.3 11.5 4.6 7.9 1.3 11.5 5.3 182 11 197 165 8.5 0.1 8.8 8.3 10/03/2006 17:30:00 6.6 0.9 9.1 3.8 6.6 0.9 9.1 3.8 6.7 0.8 8.8 4.6 190 9 196 165 8.4 0 8.5 8.3 10/03/2006 17:40:00 6.2 0.9 9.5 4.2 6.1 0.9 9.9 4.2 6.3 0.9 9.5 3.8 187 16 218 165 8.2 0 8.5 8 10/03/2006 17:50:00 5.6 1.1 8.8 2.3 5.6 1.1 8.4 2.3 5.6 1 8 3 200 13 201 165 7.8 0 8.3 7.5 10/03/2006 18:00:00 4.5 1 6.5 2.6 4.4 1 6.5 2.6 4.6 0.9 6.8 2.6 197 9 202 165 7.6 0 8 7.3 10/03/2006 18:10:00 5.8 1.2 8.8 2.6 5.6 1.1 8.4 2.6 5.9 1.2 9.1 3 190 10 182 165 7.3 0.2 7.8 7 10/03/2006 18:20:00 7.8 0.8 9.5 5.3 7.7 0.8 9.1 5.3 7.8 0.9 9.9 5.7 187 6 185 165 7.4 0 7.5 6.7 10/03/2006 18:30:00 7.2 1.1 9.9 4.9 7 1 9.1 4.6 7.2 1.1 9.9 4.6 182 8 190 165 7.3 0 7.5 7 10/03/2006 18:40:00 6 0.6 7.6 3.8 5.9 0.6 7.6 3.8 6 0.6 7.2 4.6 189 6 184 165 7.1 0 7.3 6.7 10/03/2006 18:50:00 6.1 0.6 8 4.6 6.2 0.6 8 4.6 6.1 0.6 7.6 4.2 194 10 183 165 7 0 7.5 6.7 10/03/2006 19:00:00 6.1 0.5 7.6 4.6 6 0.5 7.2 4.9 6.2 0.5 7.2 4.9 185 6 185 165 7.1 0.1 7.3 6.7 10/03/2006 19:10:00 5.5 0.9 8 3.8 5.4 0.8 7.6 3.8 5.5 0.8 8 3.8 181 6 185 165 6.9 0.1 7.3 6.5 10/03/2006 19:20:00 4.9 0.7 6.5 3 4.9 0.7 6.5 3 5 0.5 6.5 3.4 193 8 203 165 6.9 0 7.3 6.5 10/03/2006 19:30:00 5.6 0.7 7.6 3.4 5.7 0.7 8 3.4 5.7 0.6 8 3.8 195 6 199 165 7.3 0 7.5 7 10/03/2006 19:40:00 5.3 1 8 3 5.4 0.9 8 3.4 5.2 0.9 8.4 3.4 199 8 201 165 7.3 0 7.5 7 10/03/2006 19:50:00 5.9 0.8 7.6 3.8 6 0.8 7.6 3.8 6 0.8 8.4 3.8 200 6 203 165 7.3 0 7.5 7 10/03/2006 20:00:00 5.1 0.5 6.5 3.8 5.1 0.5 6.5 3.8 5.1 0.6 6.8 3.4 201 5 190 165 7.3 0 7.5 7 10/03/2006 20:10:00 4.9 0.5 6.8 3.8 5 0.5 6.8 3.8 5.1 0.5 6.5 3.8 193 6 197 165 7.3 0 7.5 7 10/03/2006 20:20:00 4.6 0.5 6.1 3.4 4.6 0.5 6.1 3.4 4.6 0.5 6.1 3.4 199 5 199 165 7.3 0.1 7.5 6.7 10/03/2006 20:30:00 4.7 0.6 6.1 3.4 4.7 0.6 5.7 3.4 4.9 0.6 6.1 3.4 193 7 172 165 7.3 0.1 7.5 6.7 10/03/2006 20:40:00 4.5 0.6 6.8 3.4 4.6 0.6 6.5 3.4 4.5 0.5 5.7 3 201 6 177 165 7.3 0.2 7.5 6.7 10/03/2006 20:50:00 4.7 0.8 7.6 3 4.8 0.8 7.6 3 4.8 0.8 7.6 3 202 7 212 165 7.3 0.1 7.5 6.7 10/03/2006 21:00:00 5.7 0.6 7.2 3.4 5.8 0.6 7.6 3.8 5.8 0.6 7.6 3.8 203 6 210 165 7.3 0.1 7.5 6.7 10/03/2006 21:10:00 6.7 0.6 9.1 5.3 6.9 0.6 9.1 5.3 6.8 0.6 8.4 5.3 204 5 205 165 7.2 0.1 7.5 6.5 10/03/2006 21:20:00 6.8 0.6 9.1 5.3 7 0.6 9.1 5.3 6.6 0.7 8.8 5.3 214 5 215 165 7.2 0 7.5 6.7 10/03/2006 21:30:00 6.8 0.8 9.1 4.9 6.9 0.8 9.1 4.6 6.8 0.7 8.8 4.9 206 6 206 165 7.3 0.1 7.5 6.7 10/03/2006 21:40:00 5.5 0.6 7.6 3.4 5.5 0.5 7.2 3.8 5.6 0.6 6.8 3.4 200 6 201 165 7.3 0 7.5 6.7 10/03/2006 21:50:00 7.2 1 8.8 3.8 7.3 1 9.1 3.8 7.1 1 9.5 4.6 202 7 207 165 7.3 0.1 7.5 7 10/03/2006 22:00:00 7.1 1 9.5 4.6 7.1 1.1 9.5 4.6 6.7 1.1 9.5 4.2 208 6 208 165 7.3 0 7.8 7 10/03/2006 22:10:00 9 1 11.5 5.7 9.2 1 11.8 5.7 9 1 11.8 5.7 203 4 208 165 7.3 0 7.5 6.7 10/03/2006 22:20:00 9.9 0.9 12.2 7.6 10.2 1 12.6 8 9.9 1 12.6 7.2 205 6 198 165 7.6 0 7.8 7 10/03/2006 22:30:00 8.3 0.9 11.1 6.1 8.3 1 11.5 6.1 8.6 1 11.8 6.1 202 6 203 165 7.6 0 8 7 10/03/2006 22:40:00 8.6 1 12.2 6.5 8.7 1 12.2 6.8 8.9 1.1 12.2 6.1 206 5 197 165 7.7 0 8 7.3 10/03/2006 22:50:00 8.3 0.9 11.5 6.1 8.3 1 11.1 6.1 8.5 1.1 11.8 5.3 198 6 201 165 7.8 0 8.3 7.3 10/03/2006 23:00:00 8.2 1.2 11.8 5.7 8.2 1.2 11.8 5.7 8.3 1.1 11.8 6.1 192 8 200 165 7.7 0 8 7.3 10/03/2006 23:10:00 6.5 1.1 8.8 3.8 6.4 1.1 9.1 4.2 6.6 1.2 9.1 3.4 194 10 203 165 7.8 0 8 7.3 10/03/2006 23:20:00 5.6 1.3 8.4 1.9 5.5 1.2 8 2.3 5.6 1.3 8.4 2.6 192 17 177 165 7.6 0 7.8 7.3 10/03/2006 23:30:00 3 1.2 5.7 0.4 3 1.2 5.7 0.4 3.3 1.1 6.1 0.4 177 15 185 165 7.4 0 7.5 7.3 10/03/2006 23:40:00 5 1 7.6 2.6 5.1 1 8 2.6 4.9 0.9 7.6 3 203 13 217 165 7.4 0 7.5 7.3 10/03/2006 23:50:00 4.8 1 7.6 2.3 4.9 1.1 7.6 2.6 5 1 6.8 3 205 12 213 165 7.5 0 7.8 7.5 10/04/2006 00:00:00 3.2 0.5 4.9 1.9 3.2 0.6 4.9 1.9 3.7 0.5 4.9 2.6 198 9 206 165 7.4 0.1 7.8 7.3 10/04/2006 00:10:00 3.2 0.6 4.9 1.5 3.1 0.6 4.9 1.5 3.3 0.7 4.9 1.5 206 10 219 165 7.5 0 7.8 7.3 10/04/2006 00:20:00 3.1 0.8 5.3 0.7 3.1 0.8 5.7 1.1 3.3 0.8 6.1 1.9 201 8 203 165 7.8 0 8 7.5 10/04/2006 00:30:00 3.6 1 6.5 0.7 3.6 1 6.5 0.7 3.6 1 6.1 0.7 187 21 226 165 7.7 0 8 7.5 10/04/2006 00:40:00 4.9 0.7 6.5 2.6 4.8 0.7 6.5 2.6 4.9 0.7 6.5 2.6 192 7 200 165 7.8 0 8 7.5 10/04/2006 00:50:00 3.7 1.1 4.9 0.4 3.6 1.1 4.9 0.4 4 1.1 5.7 0.4 190 12 199 165 7.8 0 8 7.8 10/04/2006 01:00:00 2.4 0.9 4.6 0.7 2.3 0.9 4.9 0.4 2.8 0.7 4.9 1.5 187 18 186 165 8.1 0.2 8.5 7.8 10/04/2006 01:10:00 4.2 0.9 6.1 2.3 4.2 0.9 6.1 2.3 4.4 1 6.5 2.3 193 9 206 165 7.9 0 8.3 7.8 10/04/2006 01:20:00 5.4 0.4 6.5 4.2 5.5 0.5 6.5 4.2 5.8 0.5 6.8 4.6 211 4 213 165 7.8 0 8 7.5 10/04/2006 01:30:00 5.3 0.7 6.8 3 5.3 0.7 6.8 3 5.3 0.6 6.5 3.8 217 4 217 165 8 0 8.3 7.8 10/04/2006 01:40:00 4.7 0.7 6.1 2.3 4.8 0.8 6.5 2.6 5 0.7 6.5 3 211 10 216 165 8.2 0.2 8.8 7.8 10/04/2006 01:50:00 5.6 1.2 8.4 3.4 5.6 1.1 8 3.4 5.9 1.1 8.8 3 197 7 197 165 8.5 0 9 8.3 10/04/2006 02:00:00 6.7 0.7 8 4.6 6.7 0.7 8 4.6 6.7 0.7 8.4 4.6 204 6 191 165 8 0 8.5 7.8 10/04/2006 02:10:00 6.9 0.5 8.8 5.7 7 0.5 8.8 5.7 6.8 0.7 8.4 4.6 207 4 208 165 7.9 0 8.3 7.5 10/04/2006 02:20:00 6.8 0.9 8.4 4.2 6.8 0.9 8.8 4.2 6.7 1 9.1 4.2 204 8 205 165 7.8 0 8.3 7.5 10/04/2006 02:30:00 7.4 0.8 9.1 5.3 7.4 0.8 9.1 5.3 7.3 0.8 9.5 5.3 199 9 184 165 7.9 0 8 7.5 10/04/2006 02:40:00 7.5 0.9 9.9 4.6 7.3 1 9.1 4.6 7.5 1 9.5 4.9 188 10 176 165 7.8 0 8 7.5 10/04/2006 02:50:00 8.2 1 10.3 5.7 8.2 0.9 10.3 6.1 8.2 1.1 11.1 4.9 192 6 190 165 7.9 0 8.3 7.5 10/04/2006 03:00:00 6.5 0.7 8.4 4.2 6.3 0.7 8 4.2 6.4 0.8 8.4 4.6 181 7 176 165 7.6 0.1 8.3 7.3 10/04/2006 03:10:00 6.1 0.6 7.6 4.6 5.9 0.6 7.6 4.2 6 0.7 7.6 4.2 182 8 191 165 7.4 0 7.8 7.3 10/04/2006 03:20:00 5.5 0.7 7.2 3.8 5.2 0.6 6.8 3.8 5.5 0.7 7.6 3.8 174 7 179 165 7.6 0 7.8 7.3 10/04/2006 03:30:00 5.2 0.5 6.8 3.8 5 0.5 6.5 3.8 5.3 0.5 6.8 4.2 172 10 181 165 7.6 0 7.8 7.5 10/04/2006 03:40:00 3.7 0.7 5.7 2.3 3.6 0.6 5.7 2.3 3.9 0.6 6.1 2.6 174 11 179 165 7.7 0 8 7.3 10/04/2006 03:50:00 3.3 0.5 4.6 1.5 3.3 0.5 4.2 1.5 3.5 0.4 4.6 2.3 201 9 198 165 7.6 0 7.8 7.3 10/04/2006 04:00:00 2.9 0.4 3.8 1.9 3.1 0.4 4.2 1.9 3.2 0.5 4.2 1.5 216 10 218 165 7.8 0.1 8 7.3 10/04/2006 04:10:00 2.2 0.5 3.4 0.7 2.3 0.5 3.4 0.7 2.7 0.4 3.8 1.9 222 10 236 165 8.3 0 8.5 8 10/04/2006 04:20:00 2.6 0.5 3.8 1.5 2.7 0.5 4.2 1.5 3 0.5 4.2 1.9 224 9 227 165 8.2 0 8.5 8 10/04/2006 04:30:00 2.9 0.6 4.2 1.1 3.5 0.4 4.9 2.6 3.6 0.4 4.6 2.6 257 8 270 165 8.3 0 8.5 8 10/04/2006 04:40:00 2.9 0.6 4.2 0.7 3.3 0.5 4.6 2.3 3.5 0.4 4.6 2.6 270 7 272 165 8.2 0.1 8.5 8 10/04/2006 04:50:00 3.4 0.6 5.3 1.9 4.3 0.8 5.7 2.3 4.1 0.8 5.7 2.3 256 13 276 165 8.1 0 8.3 7.8 10/04/2006 05:00:00 2.1 0.7 3.8 0.4 2.3 0.7 3.8 0.4 2.4 0.5 3.4 0.7 238 15 246 165 7.9 0 8.3 7.8 10/04/2006 05:10:00 1.4 0.7 3 0.4 1.4 0.7 3 0.4 1.9 0.6 3 0.7 205 19 224 165 7.9 0 8.3 7.8 10/04/2006 05:20:00 2.3 0.7 4.2 0.7 2.3 0.7 4.2 0.7 2.5 0.5 4.2 1.5 229 10 242 165 8.1 0 8.5 7.5 10/04/2006 05:30:00 2.1 0.7 3.8 0.7 2.2 0.7 3.8 1.1 2.5 0.6 4.2 1.9 220 6 212 165 8.1 0 8.5 8 10/04/2006 05:40:00 2.8 0.7 4.2 0.7 2.8 0.7 4.2 0.7 3 0.6 4.6 1.5 216 9 215 165 8.3 0 8.5 8 10/04/2006 05:50:00 4.4 0.5 5.7 2.6 4.6 0.5 5.7 2.6 4.6 0.5 5.7 3 214 4 219 165 8.2 0 8.5 8 10/04/2006 06:00:00 5.4 0.5 6.8 3.8 5.5 0.5 6.8 4.2 5.6 0.6 7.2 3.8 206 4 206 165 8 0 8.5 7.8 10/04/2006 06:10:00 7 0.5 8 5.7 7.1 0.5 8.4 6.1 7.2 0.5 8.4 5.7 207 3 212 165 7.8 0 8 7.5 10/04/2006 06:20:00 6.4 0.4 7.6 4.9 6.6 0.5 7.6 5.3 6.4 0.5 8 4.2 210 2 212 165 7.7 0 8 7.3 10/04/2006 06:30:00 6.4 0.5 7.2 4.6 6.5 0.5 7.6 4.9 6.3 0.7 7.6 4.2 201 5 208 165 7.6 0 8 7.3 10/04/2006 06:40:00 6.5 0.4 7.2 5.3 6.6 0.4 7.6 5.7 6.5 0.5 7.6 4.9 200 3 199 165 7.4 0 7.8 7 10/04/2006 06:50:00 6.1 0.4 7.6 4.9 6.2 0.4 7.2 4.9 6.1 0.5 7.2 4.6 201 3 198 165 7.6 0 7.8 7 10/04/2006 07:00:00 5.4 0.8 6.8 3.4 5.4 0.8 6.8 3.4 5.3 0.8 7.2 3.4 196 6 204 165 7.4 0.1 7.8 7 10/04/2006 07:10:00 5.8 0.8 7.6 3.4 5.8 0.8 7.2 3.8 5.8 0.8 7.6 3.8 194 6 200 165 7.3 0 7.5 6.7 10/04/2006 07:20:00 5.6 0.5 6.8 4.6 5.6 0.4 6.5 4.6 5.9 0.4 6.8 4.6 192 3 193 165 7.3 0 7.5 7 10/04/2006 07:30:00 5.4 0.8 6.8 3 5.5 0.8 6.8 3.4 5.5 0.9 6.8 3.4 199 7 200 165 7.4 0.1 7.5 7 10/04/2006 07:40:00 5.4 0.8 6.8 3.4 5.5 0.8 6.8 3.4 5.6 1 7.2 3.4 204 4 202 165 7.3 0 7.5 6.7 10/04/2006 07:50:00 5 0.7 6.8 3.4 4.9 0.7 6.8 3.4 5.2 0.7 7.2 3.8 192 7 193 165 7.1 0 7.3 6.7 10/04/2006 08:00:00 6 1.2 9.9 3.8 5.8 1.2 9.5 3.8 5.8 1 9.1 3.8 186 9 198 165 7.2 0 7.5 6.7 10/04/2006 08:10:00 7.3 0.7 9.5 5.3 7.1 0.7 9.1 5.3 7.3 0.7 9.5 5.7 195 6 192 165 7.3 0.1 7.8 7 10/04/2006 08:20:00 6.6 0.7 8 4.6 6.7 0.7 8 4.6 6.6 0.6 8 4.9 198 5 201 165 7.9 0.1 8.3 7.5 10/04/2006 08:30:00 7.5 0.9 9.5 4.9 7.4 0.8 9.1 5.3 7.6 0.9 9.9 5.3 190 7 196 165 8 0.2 8.3 7.3 10/04/2006 08:40:00 7.4 0.8 9.5 5.3 7.4 0.8 9.1 5.3 7.5 1 9.9 5.3 197 6 190 165 7.8 0.1 8 7.3 10/04/2006 08:50:00 6.5 1 9.5 4.6 6.5 1 9.1 4.6 6.8 0.9 9.5 4.2 199 7 200 165 8.1 0.1 8.5 7.5 10/04/2006 09:00:00 5.9 1 8.4 3.8 6 1 8.8 3.4 6 0.9 8.4 3.8 207 8 209 165 7.9 0.2 8.3 7.3 10/04/2006 09:10:00 6.8 1.1 9.9 3.8 6.9 1.1 9.5 3.8 6.8 1.1 9.5 4.6 198 9 200 165 7.9 0.1 8.3 7.3 10/04/2006 09:20:00 7.6 0.7 9.5 6.1 7.8 0.7 9.5 6.1 7.7 0.8 9.9 5.7 202 4 202 165 8.3 0.2 8.5 7.8 10/04/2006 09:30:00 5.6 0.8 8 3.8 5.4 0.9 8.4 3.8 5.8 0.8 9.1 4.2 181 12 200 165 8.5 0.2 8.8 7.8 10/04/2006 09:40:00 5.3 0.7 6.5 3.8 5.1 0.6 6.1 3.4 5.6 0.6 6.8 4.2 172 9 182 165 8.5 0.1 8.8 7.8 10/04/2006 09:50:00 6.1 0.8 7.6 3.4 5.8 0.8 7.6 3 6.2 0.8 7.6 4.2 167 8 167 165 8.7 0.1 9 8.3 10/04/2006 10:00:00 4.8 0.6 6.5 3.4 4.6 0.5 6.5 3.4 5.2 0.5 7.2 3.8 162 6 179 165 9.6 0.2 9.8 8.8 10/04/2006 10:10:00 5.3 0.6 6.5 3.8 5.1 0.6 6.5 3.8 5.5 0.6 6.8 4.2 158 15 173 165 9.9 0.3 10.6 9.3 10/04/2006 10:20:00 6.6 0.8 8.8 4.9 6.4 0.7 8.4 4.9 6.8 0.8 8.8 5.3 158 5 174 165 10.3 0.1 10.9 9.8 10/04/2006 10:30:00 8 0.8 10.3 6.1 7.8 0.8 9.9 5.7 8.3 0.9 10.3 6.1 170 17 90 165 9.1 0.4 9.8 8.5 10/04/2006 10:40:00 9.2 1 11.8 5.3 9.1 1 12.2 6.1 9.4 1 11.8 6.5 180 9 186 165 8.3 0.1 9 7.8 10/04/2006 10:50:00 7.8 1 10.7 4.6 7.6 1 10.7 4.6 8 0.9 10.3 5.7 182 9 196 165 8.5 0.1 9 8 10/04/2006 11:00:00 8.5 1.5 11.8 4.9 8.3 1.4 11.5 5.3 8.7 1.3 12.2 6.1 181 8 169 165 8.9 0 9 8.3 10/04/2006 11:10:00 8.8 1.2 12.6 6.5 8.6 1.1 11.8 6.1 8.9 1.2 12.6 6.5 182 9 176 165 8.8 0 9 8.3 10/04/2006 11:20:00 11.1 1.5 15.6 7.2 11 1.5 14.9 7.2 11.3 1.5 15.3 8 180 12 186 165 9 0.1 9.6 8.5 10/04/2006 11:30:00 9.4 1.1 12.6 6.5 9.2 1 12.2 6.8 9.7 1 13 7.2 179 13 178 165 9.3 0 9.6 9 10/04/2006 11:40:00 8.2 1.1 11.5 5.7 8 1.1 11.1 5.3 8.5 1.2 12.2 5.3 175 9 173 165 9.7 0.4 10.3 8.8 10/04/2006 11:50:00 7 1 11.1 4.9 6.9 1 11.1 4.6 7.2 1 10.7 4.6 181 12 187 165 10.1 0.2 10.6 9.3 10/04/2006 12:00:00 7.4 1 9.9 4.9 7.3 1 9.9 4.6 7.6 1 10.3 5.3 186 12 189 165 10.8 0.1 11.1 10.1 10/04/2006 12:10:00 7.4 1.5 11.8 4.2 7.3 1.5 11.5 4.2 7.6 1.4 11.1 4.6 180 11 165 165 10.9 0.1 11.1 10.3 10/04/2006 12:20:00 7.9 1.1 11.8 4.9 7.7 1.1 11.1 4.6 8.2 1.1 11.5 5.7 174 12 177 165 10.5 0.4 11.1 9.6 10/04/2006 12:30:00 9.2 1 11.8 6.8 9 1 11.1 6.8 9.4 1.1 13 6.8 177 9 181 165 9.3 0.3 9.8 8.8 10/04/2006 12:40:00 9.4 1.5 13 6.5 9.4 1.5 12.6 6.1 9.6 1.5 13.3 6.8 186 9 185 165 8.7 0.1 9 8.3 10/04/2006 12:50:00 10.2 1.5 14.5 6.5 10.1 1.5 13.3 6.8 10.5 1.6 14.5 6.8 181 11 176 165 8.5 0 8.8 8.3 10/04/2006 13:00:00 8.9 1 11.5 5.7 8.8 1 11.1 6.1 9.2 1.1 12.6 6.8 180 11 170 165 8.6 0.3 9 8 10/04/2006 13:10:00 8.9 1.6 12.2 5.3 8.8 1.5 12.2 5.3 9.1 1.6 12.6 5.3 180 9 186 165 9 0.2 9.6 8.5 10/04/2006 13:20:00 5.1 1 7.6 3 5 1 7.6 3 5.5 1 8.8 3.4 183 12 206 165 8.6 0.2 9 8 10/04/2006 13:30:00 4.5 0.7 6.1 3 4.4 0.7 6.1 2.6 5 0.6 6.8 3.4 180 11 180 165 8.4 0.1 8.5 7.8 10/04/2006 13:40:00 4.1 0.9 6.5 1.9 4.1 0.9 6.5 1.9 4.4 0.8 6.8 2.6 192 14 191 165 8.4 0 8.8 7.8 10/04/2006 13:50:00 4.1 1.2 7.2 0.7 4.1 1.2 7.2 1.1 4.4 1.1 7.6 1.5 189 19 197 165 8.8 0.1 9 8.3 10/04/2006 14:00:00 4.7 1 6.8 2.6 4.7 1 6.8 2.6 4.9 1 7.2 2.6 204 10 204 165 8.6 0 9 8.3 10/04/2006 14:10:00 3.6 0.6 4.9 1.9 3.6 0.5 4.6 2.3 4.1 0.6 5.3 2.3 190 15 182 165 9 0.1 9.6 8.5 10/04/2006 14:20:00 4.2 0.4 5.3 3 4 0.4 4.9 2.6 4.5 0.5 5.7 3.4 182 7 183 165 8.5 0.2 9 7.8 10/04/2006 14:30:00 3.8 0.7 5.7 1.9 3.8 0.7 5.7 1.9 4.1 0.8 6.1 2.6 198 8 196 165 8.5 0.1 8.8 8 10/04/2006 14:40:00 3.5 0.7 4.9 1.5 3.5 0.8 4.9 1.5 3.7 0.7 5.3 1.9 206 8 198 165 8.8 0 9 8.3 10/04/2006 14:50:00 2.2 0.6 3.4 0.7 2.1 0.7 3.8 0.4 2.6 0.5 3.8 1.5 203 12 205 165 9 0 9.3 8.5 10/04/2006 15:00:00 3.4 0.6 4.9 1.5 3.4 0.6 4.9 1.9 3.6 0.6 5.3 1.5 216 7 220 165 9 0.1 9.3 8.5 10/04/2006 15:10:00 3.1 0.7 5.7 1.5 3 0.7 5.3 1.5 3.4 0.6 5.3 1.9 204 13 181 165 9 0 9.3 8.5 10/04/2006 15:20:00 2.7 1 4.6 0.7 2.6 1 4.6 0.4 3.1 1 4.9 1.1 211 12 207 165 9.4 0 9.6 8.8 10/04/2006 15:30:00 4.2 0.8 6.1 2.3 4.3 0.8 6.5 2.3 4.4 0.8 6.1 2.6 212 9 211 165 10.1 0.3 10.6 9.3 10/04/2006 15:40:00 3.7 0.8 5.7 1.5 3.7 0.8 6.1 1.1 4 0.8 6.1 1.5 222 8 222 165 9.8 0.2 10.6 9.3 10/04/2006 15:50:00 5.1 1.8 9.1 2.3 5.1 1.9 8.8 2.3 5.3 1.8 9.1 1.9 208 9 201 165 9.1 0.1 9.3 8.8 10/04/2006 16:00:00 5.7 1.2 8.8 3.4 5.7 1.2 8.8 3 5.9 1.2 9.5 3.4 196 11 208 165 9.8 0.4 10.6 9 10/04/2006 16:10:00 3.8 1.7 7.6 0.4 3.8 1.6 7.6 0.4 4.2 1.5 8 1.1 190 13 196 165 10.1 0.2 10.6 9.8 10/04/2006 16:20:00 3.4 0.8 5.3 1.5 3.4 0.8 5.3 1.5 3.7 0.8 5.7 1.5 188 18 196 165 9.8 0.2 10.3 9.3 10/04/2006 16:30:00 6 1.5 10.3 3 6.1 1.5 10.7 3.4 6.3 1.6 10.3 2.3 206 9 214 165 9.5 0.2 10.1 8.8 10/04/2006 16:40:00 6.6 0.8 8.4 4.2 6.7 0.9 8.8 3.8 6.6 1 9.1 3.8 203 9 205 165 9.4 0.2 9.8 8.8 10/04/2006 16:50:00 6.2 0.9 8.4 4.6 6.3 0.9 8.8 4.2 6.3 0.8 8 4.2 204 7 208 165 9.4 0.2 9.6 8.8 10/04/2006 17:00:00 7.8 0.8 9.5 5.3 7.9 0.9 9.9 5.3 7.6 0.9 9.9 5.3 201 5 206 165 8.7 0.2 9.3 8.5 10/04/2006 17:10:00 7.8 0.7 9.5 5.3 7.8 0.7 9.1 4.9 7.8 0.7 10.3 5.7 198 5 201 165 8.6 0.1 9 8.5 10/04/2006 17:20:00 7.1 0.8 8.8 4.9 7.1 0.8 8.8 4.9 7.1 1 9.1 4.9 194 5 192 165 8.9 0 9 8.8 10/04/2006 17:30:00 5.9 0.7 7.6 3.4 5.8 0.7 7.2 3.8 6.3 0.7 8 4.2 187 6 185 165 8.6 0.1 9 8.3 10/04/2006 17:40:00 6.8 0.6 8.4 4.9 6.7 0.6 8 4.9 6.9 0.7 8.4 5.3 190 5 193 165 8.4 0.1 8.8 7.8 10/04/2006 17:50:00 6.7 0.7 8.8 4.9 6.6 0.7 8.4 4.9 6.8 0.6 8.8 4.9 193 6 196 165 8.1 0.2 8.5 7.5 10/04/2006 18:00:00 6.9 0.6 8.8 5.3 6.8 0.6 8.4 4.9 7 0.7 9.1 5.3 193 5 197 165 7.8 0.2 8 7.3 10/04/2006 18:10:00 6.6 0.6 8 4.9 6.6 0.6 8 4.9 6.5 0.8 8.4 4.2 199 5 194 165 7.7 0 8 7 10/04/2006 18:20:00 6.1 0.7 8 4.2 6.1 0.6 7.6 4.6 6 0.6 7.6 4.2 196 5 194 165 7.6 0 8 7.5 10/04/2006 18:30:00 5.4 0.7 7.2 3.4 5.5 0.7 7.2 3.8 5.4 0.8 7.2 3.8 202 5 204 165 7.6 0 7.8 7.3 10/04/2006 18:40:00 5.4 0.7 7.2 3.4 5.5 0.7 7.2 3.4 5.3 0.8 6.8 3.4 199 6 195 165 7.4 0.1 7.5 7 10/04/2006 18:50:00 4.1 0.7 5.7 2.3 4.2 0.7 5.7 2.3 4.2 0.7 6.1 2.3 206 7 205 165 7.4 0 7.5 7.3 10/04/2006 19:00:00 4.1 0.5 6.1 3 4.2 0.5 6.1 3.4 4.5 0.5 6.5 3.4 202 5 203 165 7.3 0.1 7.5 7 10/04/2006 19:10:00 4.8 0.5 6.1 3.4 5 0.5 6.1 3.4 5 0.6 6.5 3.4 206 5 198 165 7.2 0 7.5 7 10/04/2006 19:20:00 4.9 0.5 6.1 3 5 0.5 6.1 3 5 0.6 6.5 3 208 5 205 165 7.3 0.1 7.5 6.7 10/04/2006 19:30:00 5.5 0.5 6.5 4.2 5.6 0.5 6.5 4.2 5.7 0.5 7.2 4.2 200 5 202 165 7.3 0.1 7.5 6.7 10/04/2006 19:40:00 5.1 0.4 6.1 3.8 5.2 0.4 6.1 4.2 5.3 0.6 6.5 3.8 198 4 203 165 7.2 0.1 7.5 6.7 10/04/2006 19:50:00 5.7 0.6 6.8 4.2 5.7 0.6 7.2 4.2 5.8 0.6 7.6 4.6 193 5 199 165 7.2 0 7.5 6.7 10/04/2006 20:00:00 5.6 0.9 7.6 3 5.6 0.8 7.6 3 5.8 0.9 7.6 3 189 9 182 165 7.2 0.1 7.5 6.7 10/04/2006 20:10:00 6 0.5 7.2 4.6 5.8 0.5 7.2 4.6 6.1 0.6 7.6 4.6 183 7 179 165 7.2 0.2 7.5 6.7 10/04/2006 20:20:00 5.9 0.7 7.2 4.2 5.9 0.7 7.6 4.2 6 0.7 7.6 4.2 195 5 189 165 7.1 0 7.3 6.5 10/04/2006 20:30:00 5 0.7 6.8 3.8 5.1 0.8 6.8 3.8 5.1 0.7 6.5 3.4 202 6 208 165 7.1 0 7.3 6.7 10/04/2006 20:40:00 5 0.3 6.1 4.2 5 0.4 6.1 4.2 5.3 0.4 6.1 4.6 200 5 199 165 7.2 0.1 7.5 6.7 10/04/2006 20:50:00 4.3 0.3 5.3 3.4 4.2 0.3 4.9 3.4 4.4 0.3 5.3 3.8 185 3 183 165 7.1 0 7.5 6.7 10/04/2006 21:00:00 3.5 0.5 4.6 1.9 3.5 0.5 4.6 1.9 3.6 0.5 4.9 2.3 199 12 185 165 7.3 0.2 7.8 7 10/04/2006 21:10:00 1.8 0.8 3.4 0.4 1.9 0.8 3.4 0.4 2.2 0.7 3.8 0.7 186 14 213 165 7.7 0 8 7 10/04/2006 21:20:00 1.2 0.8 3.4 0.4 1.4 0.9 3.8 0.4 1.7 0.8 4.2 0.4 217 39 253 165 7.9 0.2 8.3 7.3 10/04/2006 21:30:00 0.6 0.4 1.9 0.4 0.6 0.4 1.9 0.4 1.1 0.5 2.3 0.4 156 29 165 165 7.6 0.2 8.3 7.3 10/04/2006 21:40:00 0.4 0.2 1.5 0.4 0.4 0.2 1.5 0.4 1 0.4 1.9 0.4 131 53 116 165 7.3 0 7.5 7 10/04/2006 21:50:00 0.5 0.3 1.5 0.4 0.5 0.3 1.5 0.4 0.8 0.5 1.9 0.4 60 58 114 165 7.3 0.1 7.5 7 10/04/2006 22:00:00 1.4 0.5 2.6 0.4 1.4 0.5 2.6 0.4 1.9 0.4 2.6 0.7 116 8 121 165 7.3 0 7.5 7 10/04/2006 22:10:00 1.3 1 3.4 0.4 1.3 1 3.4 0.4 2 0.7 3.8 0.4 152 39 149 165 7.5 0.2 8 7 10/04/2006 22:20:00 1.4 1.1 6.5 0.4 1.4 1.1 4.9 0.4 1.9 1 5.7 0.4 175 76 277 165 7.8 0.2 8.5 7.5 10/04/2006 22:30:00 1.5 1 4.2 0.4 1.4 1 3.8 0.4 1.9 0.8 4.6 0.4 166 35 215 165 8 0 8.3 7.8 10/04/2006 22:40:00 1.7 1.3 6.5 0.4 1.6 1.4 6.1 0.4 1.9 1.2 6.5 0.4 239 51 307 165 8.3 0 8.5 7.8 10/04/2006 22:50:00 0.9 0.6 2.6 0.4 1 0.6 2.3 0.4 1.1 0.7 2.6 0.4 250 32 269 165 8.2 0.1 8.5 8 10/04/2006 23:00:00 3.4 1.3 6.1 0.4 3.6 1.4 6.5 0.4 3.5 1.2 6.1 0.7 253 24 280 165 8.3 0.1 8.5 7.8 10/04/2006 23:10:00 6.2 1.2 9.5 3 6.7 1.3 9.5 3.4 6.2 1.2 9.5 3.4 276 9 273 165 8.4 0 8.5 8.3 10/04/2006 23:20:00 7.1 1.3 11.1 4.6 7.9 1.6 11.8 4.6 7.4 1.6 11.5 4.2 274 7 278 165 8.5 0.1 8.8 8.3 10/04/2006 23:30:00 6.9 1.3 11.1 4.2 7.5 1.6 12.2 4.6 7 1.7 11.8 3.8 274 15 250 165 8.5 0.2 9 8 10/04/2006 23:40:00 7.2 1 9.5 4.9 7.3 1 9.9 4.6 6.4 1.3 9.5 3.8 287 11 282 165 8.4 0 8.8 8 10/04/2006 23:50:00 8 1.5 11.1 4.9 8 1.6 11.1 4.6 6.7 1.5 10.7 3.8 293 8 290 165 8.1 0.1 8.5 8 10/05/2006 00:00:00 8.5 1.2 11.5 4.6 8.5 1.3 11.5 5.3 7.4 1.5 11.5 4.2 288 7 292 165 8.5 0 9 8 10/05/2006 00:10:00 7.9 1.2 10.7 5.3 8 1.1 11.1 5.3 7.3 1.2 11.1 4.6 283 5 288 165 8.3 0 8.5 8 10/05/2006 00:20:00 7.1 0.8 9.5 4.9 7.2 0.8 9.5 4.9 6.5 1 9.1 3.8 286 8 281 165 8.2 0 8.5 8 10/05/2006 00:30:00 8.3 0.7 10.3 6.8 8.5 0.7 10.3 6.8 8.3 0.8 10.7 6.5 282 4 274 165 8.3 0 8.5 8 10/05/2006 00:40:00 8.4 1.2 11.1 4.2 8.5 1.2 11.1 5.7 7.7 1.2 10.7 4.6 285 6 291 165 8.4 0 8.5 8 10/05/2006 00:50:00 9.1 1.6 13.7 5.7 9.2 1.6 14.1 6.1 8.7 1.5 12.6 5.7 284 6 288 165 8.5 0.2 8.8 7.8 10/05/2006 01:00:00 7.4 0.8 9.1 4.6 7.6 0.8 9.5 5.7 7.1 0.9 9.1 4.9 279 6 282 165 8.5 0 8.8 7.8 10/05/2006 01:10:00 6.7 1.2 9.9 3.8 6.9 1.2 9.9 4.6 6.6 1.2 9.5 3.8 278 9 279 165 8.3 0 8.5 8 10/05/2006 01:20:00 7 1.2 10.7 3.8 7.3 1.1 10.7 4.9 6.7 1.1 9.9 3.4 281 10 293 165 8.3 0 8.5 8 10/05/2006 01:30:00 8.9 1.6 13.3 4.6 8.9 1.5 13.3 4.6 7.9 1.6 11.5 3.4 289 11 286 165 8.6 0.1 8.8 8 10/05/2006 01:40:00 7.6 2.3 13.3 2.6 8 2.7 15.3 3.8 7.1 3.2 14.9 1.9 290 20 277 165 8.7 0.2 9 7.8 10/05/2006 01:50:00 4.7 1.6 10.3 1.1 4.9 1.6 10.3 1.5 4.1 1.2 8 1.9 289 18 264 165 8.2 0 8.5 7.8 10/05/2006 02:00:00 5.7 2 12.2 1.9 5.7 1.8 11.8 2.3 4.9 1.7 9.9 1.9 296 17 305 165 8.4 0 8.5 8 10/05/2006 02:10:00 8.4 2.2 13.7 4.2 8.9 2.3 14.5 4.2 8.2 2.4 14.5 3.4 280 15 281 165 8.5 0.2 8.8 8 10/05/2006 02:20:00 4.7 1.5 8.4 1.5 5.1 1.5 8.4 2.3 4.5 1.3 8.4 2.3 281 18 295 165 8.5 0 8.8 8 10/05/2006 02:30:00 4.8 1.4 8 1.5 5 1.3 8 1.9 4.4 1.4 8.4 1.5 282 17 280 165 8.4 0 8.5 8.3 10/05/2006 02:40:00 4.9 2 9.9 1.9 5 1.9 10.3 1.9 4.5 1.6 11.1 1.9 290 15 297 165 8.2 0 8.5 8 10/05/2006 02:50:00 8.2 1.6 12.6 3 8.3 1.6 12.2 3 7.4 1.7 11.5 3.8 284 18 283 165 8.2 0 8.5 7.8 10/05/2006 03:00:00 7.2 1.6 11.8 3 7.5 1.5 11.8 3.8 6.6 1.3 9.9 3.4 284 13 290 165 8 0.1 8.5 7.8 10/05/2006 03:10:00 8.3 1.2 11.8 5.3 8.6 1.3 12.6 4.9 7.8 1.6 11.8 3.4 286 15 278 165 7.9 0.1 8.3 7.8 10/05/2006 03:20:00 8.8 1.6 12.6 4.6 9.1 1.7 14.5 4.9 8.2 1.9 14.1 4.2 288 15 270 165 8 0 8.3 7.8 10/05/2006 03:30:00 10.2 1.3 13.3 6.8 10.3 1.3 13.3 7.2 9.3 1.7 13.7 5.3 286 8 288 165 7.9 0 8 7.5 10/05/2006 03:40:00 9.2 1.5 13.3 5.3 9.3 1.7 13.3 5.3 8.4 1.8 13.3 4.6 283 9 288 165 7.9 0 8 7.5 10/05/2006 03:50:00 9.8 1.5 13.7 5.3 10 1.3 13.3 6.8 9.1 1.6 12.6 5.7 284 9 280 165 7.8 0 8 7.8 10/05/2006 04:00:00 8.6 1.9 13 3.8 9.3 1.8 13 4.2 8.5 2 12.6 3 277 13 275 165 7.7 0 8 7.5 10/05/2006 04:10:00 7.8 1.8 14.9 4.6 8.1 1.7 14.9 4.6 7.4 1.8 14.5 3 282 10 277 165 7.8 0 8 7.5 10/05/2006 04:20:00 5.6 1.4 11.1 2.3 6 1.4 12.2 2.6 5.7 1.5 12.2 2.3 278 11 252 165 7.8 0 8 7.5 10/05/2006 04:30:00 6.2 1.3 10.7 2.6 6.5 1.4 11.1 3 6.2 1.3 9.5 3 278 12 287 165 7.6 0 7.8 7.5 10/05/2006 04:40:00 7.3 1.8 10.7 3 7.5 1.7 11.1 3.8 6.7 1.4 10.7 3.4 285 14 298 165 7.6 0 7.8 7.5 10/05/2006 04:50:00 4.9 1.2 9.1 2.3 5.3 1.1 9.1 3 5 0.9 8 3 274 14 248 165 7.4 0.1 7.8 7.3 10/05/2006 05:00:00 4.8 1.3 7.6 2.3 5.2 1.1 8 2.6 4.9 1 7.6 3 277 13 284 165 7.3 0 7.8 7 10/05/2006 05:10:00 7.9 1.8 12.6 4.2 8 1.8 12.2 4.6 7.2 1.7 11.5 3.8 288 9 294 165 7.4 0 7.8 7.3 10/05/2006 05:20:00 7.5 1.4 11.1 4.6 7.5 1.3 11.1 4.6 6.3 1.4 10.3 3.4 296 11 288 165 7.4 0 7.5 7.3 10/05/2006 05:30:00 6.8 1.1 9.5 3.8 6.8 1.1 9.5 3.8 6.2 1.3 9.9 3.4 299 14 308 165 7.4 0 7.8 7.3 10/05/2006 05:40:00 6.6 1.2 10.3 3 6.6 1.2 9.9 3.8 5.5 1.3 8.8 3 294 12 290 165 7.5 0 7.8 7.3 10/05/2006 05:50:00 6.8 1.3 10.7 3.4 6.9 1.3 11.1 3.8 5.9 1.4 9.9 3.4 295 11 276 165 7.7 0 7.8 7.5 10/05/2006 06:00:00 7.8 1.3 11.5 4.2 7.8 1.3 11.8 4.9 6.8 1.4 11.5 3.4 294 12 276 165 7.8 0 8 7.5 10/05/2006 06:10:00 5.9 2.3 11.1 1.9 6.2 2.3 11.1 2.3 5.7 2.4 11.5 2.3 286 19 284 165 7.4 0.1 7.8 7.3 10/05/2006 06:20:00 6.1 1.5 10.7 3 6.5 1.5 10.7 3.4 6 1.6 10.7 2.6 274 15 265 165 7.3 0 7.5 7 10/05/2006 06:30:00 5.3 1.7 9.9 3 5.6 1.9 10.3 3 5.3 1.8 9.9 3 235 16 243 165 7.4 0.1 7.8 7 10/05/2006 06:40:00 4.5 1.3 8 1.1 5.1 1.5 8.8 1.5 4.8 1.4 8.8 1.9 250 17 264 165 7.4 0.1 7.8 7 10/05/2006 06:50:00 6.5 1.6 11.1 3 7.2 1.5 11.1 3.4 6.9 1.4 11.1 3 271 10 290 165 7.4 0 7.5 7 10/05/2006 07:00:00 11 2.4 16.8 4.9 11.2 2.3 16.4 6.1 10.1 2.3 15.3 6.1 285 8 296 165 7.3 0 7.5 7 10/05/2006 07:10:00 12.1 1.6 16.1 7.6 12.2 1.6 16.1 8 11 1.7 16.1 6.5 287 7 288 165 7.4 0.1 7.8 7.3 10/05/2006 07:20:00 11.6 1.5 15.3 8.4 11.6 1.6 15.3 8.4 10.2 2.1 15.6 6.1 293 9 288 165 7.4 0 7.5 7 10/05/2006 07:30:00 10.5 1.3 13.7 7.2 10.5 1.3 13.7 7.2 8.6 1.2 12.2 5.7 292 8 281 165 7.4 0 7.5 7.3 10/05/2006 07:40:00 8.7 1.2 12.2 6.1 9 1.3 12.6 6.1 8.7 1.4 12.2 5.3 281 9 285 165 7.4 0 7.8 7.3 10/05/2006 07:50:00 10 1 13 6.5 10.1 1 13 7.6 9.5 1.2 12.2 6.5 282 6 274 165 7.5 0 7.8 7.3 10/05/2006 08:00:00 9.5 1 12.2 6.5 9.5 1.1 12.6 6.5 8.4 1.6 12.6 4.9 287 8 281 165 7.6 0 7.8 7.5 10/05/2006 08:10:00 9.2 1.2 11.5 6.1 9.2 1.3 11.8 6.1 7.9 1.5 12.2 4.9 289 9 282 165 7.6 0 7.8 7.5 10/05/2006 08:20:00 9.1 1.5 13.3 4.9 9.1 1.5 13.3 5.3 7.7 1.6 12.6 4.2 291 7 295 165 7.6 0 7.8 7 10/05/2006 08:30:00 9.2 1.1 11.5 6.5 9.4 1.2 12.2 6.5 8.9 1.4 12.2 4.6 281 8 276 165 7.7 0 8 7 10/05/2006 08:40:00 9.9 1.3 13.3 6.1 10.1 1.3 12.6 6.5 9.5 1.6 13 5.3 284 7 277 165 8 0.1 8.5 7.3 10/05/2006 08:50:00 10.1 1.5 13.7 6.1 10.1 1.5 13.7 6.5 8.5 1.6 13 4.9 291 8 289 165 8.5 0.1 8.8 8.3 10/05/2006 09:00:00 9.1 1.7 13 4.6 9.4 1.6 13 5.7 8.1 1.3 11.8 4.2 287 10 291 165 8.7 0.1 9 8.3 10/05/2006 09:10:00 7.6 1.5 11.8 4.2 8.3 1.7 12.6 4.6 7.8 1.7 11.8 3.8 278 13 275 165 9 0.1 9.3 8.5 10/05/2006 09:20:00 8.8 1.4 13 5.3 9.9 1.3 13.7 6.8 9.4 1.3 13.3 5.7 273 10 279 165 9 0 9.3 8.8 10/05/2006 09:30:00 8.1 1.5 11.8 4.9 8.2 1.5 11.5 4.9 7.2 1.6 11.5 3.8 291 12 289 165 8.9 0 9 8.5 10/05/2006 09:40:00 9.2 1.3 13 4.6 9.2 1.3 12.6 4.6 7.9 1.4 12.2 4.9 293 10 298 165 8.5 0 9 8 10/05/2006 09:50:00 8.8 2.2 14.5 4.2 8.9 2.2 14.5 4.6 7.8 2.2 13.3 3.8 294 12 284 165 8.2 0 8.5 7.5 10/05/2006 10:00:00 9.8 2.2 16.1 4.6 9.8 2.3 15.3 4.9 8.5 2.4 13.7 3.8 291 12 294 165 8.3 0 8.8 7.5 10/05/2006 10:10:00 11.8 1.7 15.6 7.6 12.1 1.6 15.6 7.6 11 1.9 15.6 6.1 284 10 282 165 8.1 0 8.5 7.8 10/05/2006 10:20:00 10.7 1.8 14.9 5.7 11 1.8 15.3 6.5 9.9 2.1 15.3 5.3 282 11 283 165 8 0 8.3 8 10/05/2006 10:30:00 9 1.8 13.7 3.8 9.4 1.8 14.5 4.2 8.7 2 13.3 4.2 282 11 274 165 8.1 0 8.5 8 10/05/2006 10:40:00 8.6 1.7 13 4.2 8.8 1.7 13 4.2 8 1.8 12.2 3.4 284 12 282 165 8.5 0.2 9 8 10/05/2006 10:50:00 8.2 1.9 12.6 2.3 8.3 1.9 13 2.6 7.6 2.1 12.6 2.6 285 11 278 165 9.1 0.3 9.8 8.5 10/05/2006 11:00:00 8.8 2.1 14.1 4.6 9.3 2.3 15.3 4.6 8.4 2.5 14.1 3.8 281 11 280 165 9.8 0.2 10.3 9.3 10/05/2006 11:10:00 7.8 2.1 13 2.6 8.1 2.2 13.3 3.4 6.9 2.5 12.6 2.3 298 21 285 165 10.1 0.4 11.1 9.6 10/05/2006 11:20:00 6.6 2.1 13 2.6 7 2.1 12.6 3 6.1 2 10.7 2.3 289 17 282 165 10.5 0.1 11.1 10.3 10/05/2006 11:30:00 6.1 1.9 10.7 1.5 6.2 1.8 10.7 1.9 5.4 1.7 9.9 1.5 301 19 282 165 10.7 0.2 11.1 10.3 10/05/2006 11:40:00 6.7 1.7 10.7 3 7.2 1.7 11.1 3.8 6.6 1.8 11.1 3 282 17 275 165 10.5 0.1 10.9 10.3 10/05/2006 11:50:00 8.8 1.5 13.7 4.6 9.6 1.5 14.1 6.1 9.4 1.5 14.1 6.1 276 9 272 165 10.1 0.1 10.9 9.8 10/05/2006 12:00:00 10.2 1.7 14.5 6.5 11 2 15.3 6.8 10.3 2.3 14.9 5.7 277 12 244 165 10 0.1 10.6 9.6 10/05/2006 12:10:00 11.5 2 15.3 6.8 12.2 1.7 15.3 7.2 11.7 1.8 15.3 4.6 277 8 270 165 9.8 0.2 10.3 9.6 10/05/2006 12:20:00 10.8 1.6 15.3 6.1 11.2 1.6 15.3 6.8 10.4 1.7 14.5 5.7 279 9 285 165 10 0.1 10.3 9.6 10/05/2006 12:30:00 10.1 2.3 16.1 4.6 10.3 2.3 16.1 4.9 9.2 2.5 16.1 4.6 286 11 279 165 10.1 0 10.6 9.8 10/05/2006 12:40:00 8.9 2.2 14.1 3.4 9.5 2.2 14.1 4.6 8.7 2.1 13.7 3.4 279 15 302 165 10.4 0.3 11.1 9.8 10/05/2006 12:50:00 9.4 1.7 14.1 5.7 9.5 1.7 14.1 5.3 8.6 1.9 13.3 4.6 288 10 299 165 10.1 0.1 10.9 9.8 10/05/2006 13:00:00 8.6 1.3 11.8 5.3 8.9 1.2 12.2 5.7 7.9 1.4 11.8 4.9 286 10 282 165 10.4 0.2 10.9 10.3 10/05/2006 13:10:00 7.6 1.5 11.8 2.6 7.9 1.4 12.6 2.6 7.4 1.4 11.5 3.4 281 8 277 165 11 0.2 11.7 10.6 10/05/2006 13:20:00 6.6 2 13.7 3.4 6.8 1.9 13.7 3.4 6.1 1.5 11.1 3 299 18 300 165 10.5 0.3 10.9 9.6 10/05/2006 13:30:00 9.8 1.7 13.7 6.1 9.8 1.7 14.1 6.1 8.3 1.5 12.2 4.9 299 11 303 165 9.6 0 10.1 9.3 10/05/2006 13:40:00 12.5 1.5 16.1 9.1 12.5 1.5 16.4 8.8 10.2 1.7 15.6 5.7 299 8 295 165 10 0 10.3 9.6 10/05/2006 13:50:00 14.1 1.5 17.9 10.3 14.1 1.5 17.9 10.3 11.2 1.7 15.6 7.6 298 8 301 165 9.7 0 9.8 9.3 10/05/2006 14:00:00 15.2 1.7 19.5 10.3 15.2 1.8 19.9 11.1 11.9 1.7 16.4 8 298 8 292 165 9.7 0.1 10.1 9.6 10/05/2006 14:10:00 13.1 1.8 17.6 8.4 13 1.8 17.6 8 11.1 2.2 17.2 5.7 301 11 289 165 9.6 0.1 10.1 9.3 10/05/2006 14:20:00 11.3 1.6 15.3 6.8 11.3 1.6 15.3 5.7 9 1.4 13.3 5.7 299 9 296 165 9.7 0.1 9.8 9 10/05/2006 14:30:00 10.1 2 14.9 6.1 10.1 1.9 14.5 6.1 8.8 1.8 14.1 5.3 292 10 303 165 10.1 0 10.6 9.8 10/05/2006 14:40:00 8.3 1.6 12.2 4.2 8.3 1.7 13.3 4.2 7.6 1.7 12.6 4.2 299 14 280 165 10.5 0.2 11.1 10.3 10/05/2006 14:50:00 6 1.7 10.7 2.6 6.2 1.5 10.3 2.6 5.2 1.3 8.8 2.3 296 16 291 165 11.2 0.2 11.9 10.9 10/05/2006 15:00:00 4.4 1.3 7.2 1.1 4.7 1.2 7.6 1.9 4 1 7.6 1.9 295 13 315 165 11.1 0.1 11.7 10.9 10/05/2006 15:10:00 4.6 1.4 8.4 1.5 4.8 1.4 8.8 1.5 4.3 1.4 8.4 1.5 300 18 315 165 10.9 0.2 11.4 10.6 10/05/2006 15:20:00 6 1.1 8.4 2.6 6.4 1 9.1 3.4 6.2 1.1 9.1 2.6 279 8 278 165 10.7 0 11.1 10.3 10/05/2006 15:30:00 5.4 1.3 8.4 2.3 5.6 1.2 8.4 3 5.3 1.2 8 2.6 278 13 286 165 10.7 0.2 11.7 10.3 10/05/2006 15:40:00 7.1 1.3 9.5 4.2 7.1 1.3 9.9 4.2 6.2 1.2 9.9 3.8 291 8 280 165 10.3 0 10.6 10.3 10/05/2006 15:50:00 7.3 1.2 10.3 4.2 7.4 1.2 10.3 4.6 7.3 1.3 11.1 4.2 283 8 284 165 10.3 0 11.1 10.3 10/05/2006 16:00:00 6 1.3 9.1 2.3 6.1 1.2 9.1 3 5.4 1.3 9.1 2.6 289 9 282 165 10.6 0.1 10.9 10.3 10/05/2006 16:10:00 5.1 1.3 7.6 1.5 5.4 1.2 7.2 2.3 4.9 1.2 7.6 1.9 284 11 305 165 10.6 0.1 11.1 10.3 10/05/2006 16:20:00 5.1 0.8 7.2 2.3 5.5 0.7 7.2 3.4 5.1 0.8 7.2 3 281 10 282 165 10.6 0.1 11.1 10.3 10/05/2006 16:30:00 4.2 0.9 6.1 1.1 4.4 0.8 6.5 2.3 4 0.8 6.1 2.3 292 13 276 165 10.9 0 11.4 10.6 10/05/2006 16:40:00 3.3 1.1 6.1 1.5 3.7 0.9 6.5 1.9 3.6 0.8 6.5 2.3 269 18 288 165 10.9 0 11.4 10.9 10/05/2006 16:50:00 3.8 1.1 6.1 1.1 4.6 1.1 6.5 1.9 4.6 1 7.2 2.3 266 10 277 165 10.9 0.2 11.7 10.6 10/05/2006 17:00:00 6.1 1.4 8.4 2.3 6.3 1.2 8.8 3.4 6.1 1.2 8.8 3.8 281 6 280 165 10.3 0.2 10.9 10.1 10/05/2006 17:10:00 6.4 0.6 8 4.2 6.5 0.6 8 4.9 5.9 0.8 8 3.4 288 7 300 165 10 0 10.3 9.8 10/05/2006 17:20:00 5.3 0.8 7.2 3.4 5.3 0.8 7.2 3.4 4.8 0.9 7.2 2.6 301 11 290 165 10 0 10.3 9.8 10/05/2006 17:30:00 3.5 0.5 4.6 2.3 3.6 0.5 4.6 2.6 3 0.6 4.2 1.9 299 8 316 165 10.1 0 10.3 9.8 10/05/2006 17:40:00 4.5 0.6 5.7 2.6 4.6 0.6 6.1 2.6 4 0.8 5.7 2.3 289 9 293 165 9.8 0.1 10.1 9.6 10/05/2006 17:50:00 4.8 0.5 5.7 3.8 4.7 0.5 6.1 3.4 4.2 0.9 5.7 2.3 289 9 282 165 9.4 0 9.6 9 10/05/2006 18:00:00 3.3 0.5 4.2 2.3 3.2 0.5 4.2 2.3 2.9 0.5 4.2 1.9 299 9 298 165 9.2 0 9.3 9 10/05/2006 18:10:00 2.8 0.4 3.8 1.9 2.9 0.4 3.8 2.3 2.6 0.4 3.4 1.5 302 6 301 165 9 0.2 9.3 8.5 10/05/2006 18:20:00 2.4 0.5 3.8 1.1 2.8 0.4 4.2 1.9 2.7 0.5 3.8 1.5 295 9 308 165 8.4 0.1 8.8 7.8 10/05/2006 18:30:00 2.7 0.4 3.8 1.9 3.1 0.4 4.2 2.3 2.9 0.5 4.2 1.9 283 6 274 165 8.5 0.1 8.8 7.8 10/05/2006 18:40:00 3 0.5 4.2 1.5 3.4 0.4 4.6 2.3 3.2 0.4 4.2 2.3 285 4 291 165 8.3 0 8.8 7.8 10/05/2006 18:50:00 3.1 0.5 4.2 1.5 3.4 0.4 4.2 2.3 2.9 0.5 4.2 1.5 292 6 287 165 8 0 8.3 7.8 10/05/2006 19:00:00 2.7 0.5 4.2 1.5 3.1 0.5 4.2 2.3 2.7 0.6 4.6 1.5 294 6 289 165 8 0.1 8.3 7.5 10/05/2006 19:10:00 3.1 0.6 4.2 1.5 3.4 0.6 4.6 2.3 2.6 0.5 3.8 1.5 298 6 297 165 8.2 0 8.5 7.8 10/05/2006 19:20:00 3.5 0.5 4.6 2.3 3.8 0.4 4.6 2.3 2.8 0.5 4.2 1.5 297 5 298 165 8 0 8.5 7.8 10/05/2006 19:30:00 2.8 0.6 4.6 0.7 3.1 0.6 4.6 0.7 2.8 0.4 3.8 1.5 305 8 295 165 7.7 0 8.3 7.5 10/05/2006 19:40:00 3 1 4.9 0.7 3.3 0.9 5.3 1.1 2.8 0.7 4.9 1.5 295 12 282 165 7.4 0.1 7.8 7.3 10/05/2006 19:50:00 1.1 0.8 3.4 0.4 1.6 1 3.8 0.4 1.7 0.9 3.8 0.4 291 33 285 165 7.5 0 7.8 7.3 10/05/2006 20:00:00 2 1 4.2 0.4 2.4 0.9 4.2 0.4 2.5 0.7 4.6 1.1 294 23 304 165 7.6 0 7.8 7.3 10/05/2006 20:10:00 1.7 0.7 3.4 0.4 2.1 0.6 3.8 0.4 2.2 0.5 3.4 1.1 312 16 313 165 7.7 0 8 7.5 10/05/2006 20:20:00 1.1 0.8 3 0.4 1.3 0.9 3.4 0.4 1.5 0.7 3 0.4 324 27 336 165 7.9 0 8.3 7.5 10/05/2006 20:30:00 1.1 0.6 2.6 0.4 1.4 0.6 3 0.4 1.5 0.5 3 0.4 303 14 315 165 7.6 0.1 8 7 10/05/2006 20:40:00 0.4 0.1 1.1 0.4 0.4 0.2 1.5 0.4 0.6 0.3 1.5 0.4 280 13 271 165 7.5 0.1 7.8 7 10/05/2006 20:50:00 0.4 0.2 1.9 0.4 0.5 0.4 2.6 0.4 0.8 0.5 2.3 0.4 194 86 287 165 7.7 0.1 8 7 10/05/2006 21:00:00 0.4 0.1 1.1 0.4 0.5 0.2 1.5 0.4 0.8 0.4 1.5 0.4 311 82 86 165 7.9 0 8.3 7.3 10/05/2006 21:10:00 0.6 0.5 2.3 0.4 0.8 0.6 2.6 0.4 1.1 0.5 2.6 0.4 183 98 263 165 7.9 0 8.3 7.5 10/05/2006 21:20:00 0.8 0.4 1.9 0.4 1.2 0.5 2.3 0.4 1.6 0.3 2.3 0.7 275 14 289 165 7.8 0 8 7.5 10/05/2006 21:30:00 0.4 0.2 1.1 0.4 0.7 0.4 1.9 0.4 1.4 0.5 2.3 0.4 241 30 260 165 7.7 0 8 7.5 10/05/2006 21:40:00 0.4 0.2 1.1 0.4 0.5 0.3 1.5 0.4 1.1 0.2 1.5 0.4 111 8 107 165 7.6 0.1 7.8 7.3 10/05/2006 21:50:00 0.4 0 0.4 0.4 0.4 0.1 1.1 0.4 0.8 0.3 1.5 0.4 124 0 165 165 7.3 0.1 7.5 7 10/05/2006 22:00:00 0.4 0 0.4 0.4 0.4 0.1 1.1 0.4 1.1 0.3 1.9 0.4 128 8 165 165 7.3 0.2 7.5 7 10/05/2006 22:10:00 0.4 0.2 1.1 0.4 0.4 0.2 1.5 0.4 0.8 0.5 1.9 0.4 177 17 150 165 7.2 0.2 7.5 6.7 10/05/2006 22:20:00 0.4 0 0.4 0.4 0.4 0.1 1.1 0.4 0.8 0.4 1.5 0.4 175 11 165 165 7 0.3 7.5 6.2 10/05/2006 22:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0.1 0.7 0.4 167 0 165 165 6.8 0 7.3 6.7 10/05/2006 22:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 167 0 165 165 7 0.1 7.3 6.7 10/05/2006 22:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 167 0 165 165 6.4 0.2 6.7 6 10/05/2006 23:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 1 0.3 1.5 0.4 162 3 165 165 6.5 0 6.7 6 10/05/2006 23:10:00 0.4 0 0.4 0.4 0.4 0.2 1.1 0.4 0.7 0.4 1.5 0.4 153 8 165 165 6.7 0.1 7 6.2 10/05/2006 23:20:00 0.7 0.3 1.5 0.4 1.1 0.3 1.9 0.4 1.8 0.3 2.3 1.1 208 23 208 165 6.7 0 7 6.5 10/05/2006 23:30:00 0.5 0.3 1.5 0.4 0.6 0.5 1.9 0.4 1.1 0.8 2.3 0.4 264 8 246 165 7.1 0.1 7.5 6.7 10/05/2006 23:40:00 0.4 0 0.7 0.4 0.4 0.1 1.1 0.4 1.2 0.4 1.9 0.4 307 21 321 165 7.4 0 7.5 7.3 10/05/2006 23:50:00 0.6 0.3 1.1 0.4 0.9 0.4 1.5 0.4 1.7 0.3 2.3 0.7 339 4 340 165 7 0.2 7.5 6.7 10/06/2006 00:00:00 0.4 0.1 1.1 0.4 0.4 0.2 1.5 0.4 0.8 0.5 1.9 0.4 185 82 138 165 7 0.1 7.5 6.7 10/06/2006 00:10:00 1.2 0.7 2.3 0.4 1.2 0.7 2.3 0.4 1.7 0.6 3 0.7 169 4 164 165 7.2 0.2 7.5 6.5 10/06/2006 00:20:00 2.3 0.3 3 1.5 2.2 0.3 3 1.5 2.6 0.3 3 1.9 176 5 178 165 6.6 0 6.7 6.2 10/06/2006 00:30:00 2.5 0.2 3 1.9 2.4 0.2 3 1.9 2.6 0.3 3.4 2.3 177 4 179 165 6.5 0 6.7 6.2 10/06/2006 00:40:00 2.7 0.5 3.8 1.5 2.6 0.4 3.8 1.1 3 0.4 3.8 1.5 175 4 177 165 6.7 0 7 6.2 10/06/2006 00:50:00 4.2 0.4 4.9 3 4 0.4 4.9 3 4.3 0.5 5.3 3 173 6 181 165 6.6 0 7 6.2 10/06/2006 01:00:00 3.9 0.5 4.9 2.6 3.8 0.5 4.6 2.6 4 0.4 4.9 3 171 5 177 165 6.3 0.1 7 6 10/06/2006 01:10:00 4.4 0.5 5.7 3.4 4.3 0.5 5.7 3.4 4.6 0.4 5.3 3.8 175 8 191 165 6.5 0 6.7 6.2 10/06/2006 01:20:00 4.6 0.5 6.1 3.4 4.5 0.5 5.7 3.4 4.8 0.4 5.7 4.2 194 3 200 165 6.9 0.1 7.3 6.2 10/06/2006 01:30:00 5.4 0.7 7.2 4.2 5.3 0.8 7.2 3.8 5.6 0.7 7.2 4.6 189 4 190 165 6.9 0 7.3 6.7 10/06/2006 01:40:00 6.5 0.3 7.2 5.7 6.6 0.3 7.2 6.1 6.9 0.3 7.6 6.1 196 2 193 165 7.2 0.1 7.5 7 10/06/2006 01:50:00 5.7 0.4 6.8 4.9 5.9 0.4 6.8 4.9 6 0.5 7.2 4.2 201 3 195 165 7.4 0 7.5 6.7 10/06/2006 02:00:00 6.2 0.3 6.8 5.3 6.2 0.3 6.8 5.3 6.4 0.4 7.6 5.3 191 3 193 165 7.4 0.1 7.8 6.7 10/06/2006 02:10:00 6.7 0.3 7.6 5.7 6.7 0.3 7.6 5.7 6.9 0.5 8 5.7 187 2 187 165 7.4 0.1 7.8 6.7 10/06/2006 02:20:00 7.3 0.4 8.4 5.7 7.4 0.5 8.4 5.7 7.2 0.6 8.4 5.3 192 6 186 165 7.4 0 7.8 7 10/06/2006 02:30:00 5.7 0.7 7.2 4.2 5.8 0.8 7.6 4.2 5.8 0.8 7.6 4.2 199 3 201 165 7.6 0.1 7.8 7.3 10/06/2006 02:40:00 5 0.6 6.5 3 5 0.7 6.5 3.4 4.8 0.8 6.8 2.6 197 5 196 165 7.6 0.1 7.8 7 10/06/2006 02:50:00 5.1 0.4 6.1 3.8 5.2 0.4 6.1 3.8 5.1 0.5 6.5 4.2 198 4 204 165 7.6 0 7.8 7 10/06/2006 03:00:00 5.4 0.4 6.5 3.8 5.5 0.4 6.5 4.2 5.4 0.5 6.5 4.2 195 2 193 165 7.6 0.1 7.8 7 10/06/2006 03:10:00 5.2 0.4 6.1 3.8 5.2 0.4 6.1 3.4 5.3 0.4 6.1 3.8 198 4 191 165 7.6 0 7.8 7.3 10/06/2006 03:20:00 4.6 0.5 5.7 3.4 4.7 0.5 5.7 3.4 4.7 0.5 5.7 3 200 4 204 165 7.6 0 7.8 7.3 10/06/2006 03:30:00 5 0.6 6.1 3.4 4.9 0.6 6.1 3.4 5 0.6 6.1 3.8 197 4 196 165 7.6 0.1 8 7 10/06/2006 03:40:00 3.2 1 5.3 0.4 3.3 0.9 5.3 1.1 3.4 0.7 5.3 1.9 195 14 201 165 7.8 0.1 8 7.3 10/06/2006 03:50:00 3.5 0.6 4.9 2.3 3.5 0.6 4.9 2.3 3.6 0.5 4.6 2.3 198 7 205 165 7.6 0 8 7 10/06/2006 04:00:00 2.8 1.2 5.7 0.4 2.8 1.1 5.3 0.4 3.1 0.8 5.3 0.7 199 15 207 165 7.5 0.1 7.8 7 10/06/2006 04:10:00 3.9 0.6 4.9 1.9 3.9 0.6 4.9 1.9 4.1 0.6 5.3 2.6 199 7 203 165 7.6 0 7.8 7 10/06/2006 04:20:00 4.3 0.7 7.2 2.3 4.2 0.7 6.8 2.6 4.3 0.6 6.5 2.3 188 9 184 165 7.6 0.2 7.8 7 10/06/2006 04:30:00 4.2 0.5 5.3 3 4.2 0.5 5.7 3 4.3 0.5 5.7 3 189 7 192 165 7.4 0.2 7.8 7 10/06/2006 04:40:00 5.1 0.6 6.5 3.4 5 0.6 6.5 3.4 5.1 0.6 6.5 3.8 188 5 186 165 7.4 0.2 7.5 6.7 10/06/2006 04:50:00 6.2 0.8 7.6 4.2 6.1 0.7 7.2 4.2 6.3 0.8 8 4.6 181 4 184 165 7.5 0.1 7.8 7 10/06/2006 05:00:00 6.7 0.4 7.6 5.3 6.4 0.4 7.2 5.3 6.5 0.5 7.6 5.3 181 3 190 165 7.3 0.1 7.8 6.7 10/06/2006 05:10:00 6.1 0.6 7.6 4.6 5.9 0.6 7.2 4.6 6.1 0.6 7.2 4.6 184 4 189 165 7.6 0.1 8 6.7 10/06/2006 05:20:00 6 0.8 8 4.6 5.9 0.8 8 4.2 5.9 0.8 7.6 4.6 185 8 199 165 7.8 0.2 8 7 10/06/2006 05:30:00 4.9 0.9 7.2 3 4.9 0.9 7.2 3 5 0.9 7.2 3.4 187 12 193 165 8 0.2 8.5 7.5 10/06/2006 05:40:00 5 0.8 6.8 3 4.8 0.8 6.8 3 5.1 0.7 6.5 3.4 183 10 197 165 7.7 0.1 8 7.3 10/06/2006 05:50:00 4.6 0.5 6.1 3.4 4.5 0.5 5.7 3.4 4.8 0.5 6.5 3.8 182 6 192 165 7.8 0.2 8 7.3 10/06/2006 06:00:00 4 0.5 5.3 3 3.8 0.4 5.3 3 4.1 0.4 4.9 3 175 5 183 165 7.7 0 8.3 7.3 10/06/2006 06:10:00 4 0.4 5.3 3 3.9 0.4 4.9 3 4.1 0.4 4.9 3.4 175 5 178 165 7.8 0.1 8 7.3 10/06/2006 06:20:00 3.4 0.5 4.9 2.3 3.3 0.5 4.6 2.3 3.7 0.5 4.9 2.6 169 6 178 165 7.8 0.2 8.3 7.5 10/06/2006 06:30:00 3 0.3 3.8 2.3 2.9 0.3 3.4 2.3 3.3 0.3 3.8 2.6 166 9 174 165 7.8 0.2 8 7.5 10/06/2006 06:40:00 4.1 0.6 6.1 2.6 3.9 0.5 5.3 2.3 4.2 0.5 5.7 3 168 9 203 165 7.8 0.1 8 7.5 10/06/2006 06:50:00 4.2 0.4 4.9 2.6 4 0.4 4.9 2.6 4.4 0.4 5.3 3.4 166 5 170 165 7.8 0 8 7.5 10/06/2006 07:00:00 3.9 0.3 4.9 3 3.7 0.3 4.6 3 4.2 0.4 4.9 3 170 8 165 165 8 0.1 8.3 7.5 10/06/2006 07:10:00 4.3 0.5 6.1 3.4 4.2 0.5 5.7 3 4.5 0.5 6.1 3.4 176 7 175 165 7.9 0.1 8.3 7.5 10/06/2006 07:20:00 4.4 0.7 6.5 2.6 4.3 0.6 6.1 3 4.5 0.7 6.1 3 181 9 181 165 8 0.2 8.3 7.5 10/06/2006 07:30:00 4.2 0.5 5.3 3.4 4 0.4 4.9 3 4.3 0.4 5.3 3.4 174 10 171 165 7.9 0.2 8 7.3 10/06/2006 07:40:00 3.9 0.5 4.9 2.3 3.8 0.5 4.9 2.3 4.2 0.5 4.9 3 177 4 179 165 7.8 0.1 8 7.3 10/06/2006 07:50:00 4.7 0.4 5.7 3.8 4.5 0.4 5.3 3.4 4.9 0.4 6.1 3.8 169 8 165 165 7.9 0.1 8 7.5 10/06/2006 08:00:00 4.7 0.6 5.7 3 4.5 0.5 5.7 3 4.9 0.5 6.1 3.8 173 6 178 165 7.9 0.2 8 7.3 10/06/2006 08:10:00 4.7 0.5 6.5 3.8 4.5 0.6 6.5 3.4 4.8 0.5 6.5 3.8 177 6 187 165 7.9 0.1 8 7.3 10/06/2006 08:20:00 5.8 0.6 7.2 3.8 5.6 0.6 6.8 3.8 5.9 0.5 6.8 4.6 182 6 181 165 8 0.1 8.3 7.3 10/06/2006 08:30:00 5.5 0.5 7.2 4.2 5.5 0.5 7.2 4.6 5.7 0.5 7.2 4.6 186 5 193 165 8 0.1 8.3 7.5 10/06/2006 08:40:00 6.9 0.4 8 5.7 6.8 0.4 7.6 5.7 7.1 0.5 8 5.7 187 5 189 165 8.1 0 8.3 7.5 10/06/2006 08:50:00 5.9 0.5 7.2 4.9 5.7 0.5 6.8 4.6 6 0.5 7.2 5.3 173 7 181 165 8 0.2 8.5 7.5 10/06/2006 09:00:00 6.2 1 8.8 4.6 5.9 0.9 8 4.2 6.3 0.8 8.8 4.9 169 10 185 165 7.9 0.2 8.3 7.5 10/06/2006 09:10:00 5.7 0.6 7.2 4.2 5.5 0.6 6.8 4.2 5.9 0.6 7.6 4.6 170 9 175 165 8 0.2 8.3 7.5 10/06/2006 09:20:00 5.4 0.9 7.2 3.4 5.3 0.9 7.2 3.4 5.6 0.9 7.2 3.4 154 6 148 165 8 0.1 8.3 7.3 10/06/2006 09:30:00 5.3 0.5 6.8 4.2 5.2 0.5 6.5 4.2 5.6 0.5 6.8 4.6 157 7 164 165 8 0.1 8.3 7.5 10/06/2006 09:40:00 4.8 0.9 7.2 3 4.6 0.9 6.8 3 4.9 0.8 6.8 3.4 161 9 165 165 8.1 0 8.5 7.5 10/06/2006 09:50:00 5.5 0.7 7.2 3.8 5.4 0.7 7.2 3.4 5.7 0.7 7.2 4.2 152 7 160 165 8.2 0 8.5 7.8 10/06/2006 10:00:00 5.7 0.9 8 3.4 5.6 0.9 8 3.8 5.7 1 9.1 2.6 168 12 165 165 8.2 0 8.5 7.8 10/06/2006 10:10:00 8.7 1.5 12.6 5.7 8.7 1.5 12.6 5.3 8.9 1.4 12.6 6.5 186 10 200 165 8.4 0.2 8.8 7.8 10/06/2006 10:20:00 10.6 1.2 13.7 8 10.5 1.2 13.7 8 10.7 1.3 14.1 7.6 188 8 189 165 8.5 0.1 8.8 8.3 10/06/2006 10:30:00 9.8 1.4 12.6 5.7 9.7 1.4 12.6 5.7 10 1.3 13.3 6.8 184 9 184 165 8.7 0 8.8 8.5 10/06/2006 10:40:00 9 1.3 12.6 5.7 8.9 1.3 12.6 5.7 9.1 1.3 13 6.1 183 10 194 165 8.5 0.1 8.8 8.3 10/06/2006 10:50:00 9.2 1.2 13.3 7.2 9.1 1.2 13.3 6.8 9.3 1.1 12.2 6.8 183 9 206 165 8.5 0 8.8 8.3 10/06/2006 11:00:00 9.9 1.2 13.3 6.8 9.8 1.1 13 7.2 10.1 1.2 13.3 7.2 182 9 185 165 8.5 0.1 8.8 8 10/06/2006 11:10:00 7.9 1 10.3 6.1 7.6 0.9 9.9 5.7 8 1.1 11.1 6.1 164 15 162 165 8.2 0.1 8.5 7.8 10/06/2006 11:20:00 7.2 0.7 9.1 5.3 7 0.7 8.8 4.9 7.3 0.8 9.1 4.9 162 9 165 165 8.1 0 8.3 7.8 10/06/2006 11:30:00 9.8 0.9 11.5 7.6 9.6 0.9 11.5 7.2 10 1 11.8 7.6 167 4 169 165 8.1 0 8.3 7.8 10/06/2006 11:40:00 11.5 0.8 13 8.8 11.2 0.7 12.6 8.8 11.7 0.8 13.7 8.8 166 15 171 165 8.2 0 8.5 7.8 10/06/2006 11:50:00 11.5 0.8 13.3 9.5 11.3 0.8 13 9.1 11.6 1 13.7 9.1 167 14 163 165 8 0.1 8.3 7.8 10/06/2006 12:00:00 12.7 1 15.3 10.3 12.5 1 14.9 10.3 12.7 1.1 15.3 10.3 165 6 173 165 8 0.1 8.3 7.5 10/06/2006 12:10:00 13.5 1 15.6 10.7 13.3 0.9 15.6 10.7 13.5 1.1 16.1 11.1 168 13 167 165 8.1 0 8.5 7.5 10/06/2006 12:20:00 13.4 1 15.6 10.7 13.2 1 15.6 10.3 13.5 1 16.1 10.3 166 13 164 165 8.2 0 8.5 7.8 10/06/2006 12:30:00 12.2 0.8 14.1 9.9 12 0.7 13.7 9.9 12.2 0.8 14.1 9.5 166 13 163 165 8.2 0 8.5 7.8 10/06/2006 12:40:00 10.6 1 12.6 7.2 10.4 0.9 12.2 7.2 10.4 1 12.6 7.2 164 10 165 165 8.1 0 8.3 7.8 10/06/2006 12:50:00 10.3 0.7 12.2 8.4 10.1 0.7 12.2 8 10.4 0.7 12.2 8.4 165 17 167 165 8.1 0 8.5 7.8 10/06/2006 13:00:00 9.5 0.6 10.7 7.6 9.4 0.6 10.7 7.6 9.5 0.7 11.1 7.2 166 11 169 165 8.2 0 8.5 7.8 10/06/2006 13:10:00 9.6 0.8 11.8 7.2 9.3 0.7 11.5 7.2 9.6 0.9 11.5 7.6 169 5 178 165 8.1 0 8.3 7.8 10/06/2006 13:20:00 10.4 0.8 11.8 8 10.1 0.7 11.5 8 10.5 0.9 12.2 8.4 169 8 172 165 8.1 0 8.5 7.5 10/06/2006 13:30:00 9.3 0.8 10.7 7.2 9.2 0.7 10.7 6.8 9.3 0.9 11.1 6.8 166 4 170 165 8.3 0.1 8.8 8 10/06/2006 13:40:00 9.5 0.5 10.7 8 9.4 0.5 10.7 7.6 9.7 0.6 11.5 8 166 10 167 165 8.5 0 8.8 8 10/06/2006 13:50:00 10.2 0.6 11.5 8.4 10.1 0.6 11.5 8.4 10.3 0.8 12.2 8 166 9 158 165 8.4 0.1 8.5 8 10/06/2006 14:00:00 11.1 0.9 12.6 8.4 10.9 0.8 12.6 8.4 11.2 1 13 8 166 6 165 165 8.3 0 8.5 8 10/06/2006 14:10:00 11.6 0.9 13.7 9.1 11.4 0.9 13.3 9.1 11.6 1 13.7 8.4 163 12 165 165 8.2 0 8.5 7.8 10/06/2006 14:20:00 12.5 0.9 14.1 9.9 12.2 0.8 13.7 9.9 12.3 1 14.5 9.5 167 16 165 165 8.1 0 8.5 7.8 10/06/2006 14:30:00 12.2 1 14.9 9.5 12 0.9 14.5 9.5 12.2 1.1 14.9 9.9 167 13 165 165 8 0.1 8.3 7.5 10/06/2006 14:40:00 12.5 1.1 14.9 9.5 12.4 1.1 14.5 9.5 12.5 1.3 14.9 7.6 165 16 172 165 8 0 8.3 7.5 10/06/2006 14:50:00 11.7 1.2 14.5 8 11.5 1.1 14.1 8 11.6 1.4 14.5 8.4 166 7 166 165 8.1 0 8.3 7.5 10/06/2006 15:00:00 9.1 0.8 11.1 6.5 9 0.8 11.1 6.1 9 0.9 11.1 6.5 163 13 179 165 8.1 0 8.3 7.8 10/06/2006 15:10:00 9.3 0.9 11.1 6.8 9.3 0.9 11.1 6.5 9.2 1.1 11.1 6.1 162 17 165 165 8.2 0 8.5 7.8 10/06/2006 15:20:00 8.4 0.7 9.9 6.5 8.2 0.7 9.5 6.5 8.5 0.7 10.3 6.8 166 8 166 165 8.2 0 8.5 7.8 10/06/2006 15:30:00 9 1 11.5 6.5 9 1 11.5 6.1 9 1 11.5 6.8 163 11 165 165 8.3 0.1 8.5 8 10/06/2006 15:40:00 9.1 0.8 11.1 7.2 9 0.8 10.7 6.8 9.1 0.9 11.1 6.8 166 11 172 165 8.4 0.1 8.5 7.8 10/06/2006 15:50:00 8.7 0.6 9.9 7.2 8.5 0.5 9.9 6.8 8.9 0.5 10.3 7.2 168 6 169 165 8.5 0 8.8 8.3 10/06/2006 16:00:00 10.7 1 13 8 10.4 0.9 12.6 8 10.5 1 13 8 169 7 166 165 8.5 0.1 8.8 8 10/06/2006 16:10:00 12.1 0.9 14.1 9.5 11.9 0.8 14.1 9.5 12.1 1 14.5 9.1 168 7 171 165 8.5 0.1 8.8 8 10/06/2006 16:20:00 11.8 0.8 13.7 9.5 11.5 0.7 13.3 9.1 11.7 0.9 13.7 8.8 168 7 177 165 8.3 0 8.5 7.8 10/06/2006 16:30:00 11.3 0.9 13.3 8.8 11.1 0.8 13 8.8 11.1 0.8 13 8.8 168 15 172 165 8.2 0 8.5 7.8 10/06/2006 16:40:00 10.9 1.1 14.1 7.6 10.6 1 13.3 7.6 11 1.2 13.7 7.6 168 5 178 165 8.2 0 8.5 7.5 10/06/2006 16:50:00 10.8 0.8 12.6 8.4 10.6 0.7 11.8 8.4 10.8 0.8 12.6 8.8 166 7 168 165 8.3 0 8.5 7.8 10/06/2006 17:00:00 10.6 0.6 12.2 8.4 10.4 0.6 12.2 8.4 10.7 0.8 12.2 8.4 167 9 166 165 8.3 0 8.5 7.8 10/06/2006 17:10:00 10.1 0.7 12.6 8 9.9 0.6 11.8 8 10.2 0.7 12.2 8 167 10 172 165 8.2 0 8.5 7.8 10/06/2006 17:20:00 12.1 2.2 15.6 7.6 11.8 2.1 15.3 7.2 12.2 2.2 16.1 7.6 163 10 165 165 8.3 0 8.5 7.8 10/06/2006 17:30:00 14.4 1.3 17.2 11.1 14.1 1.2 16.4 11.1 14.4 1.3 17.6 11.5 166 15 165 165 8.1 0.1 8.5 7.5 10/06/2006 17:40:00 14.8 1.2 17.6 11.5 14.5 1.1 17.2 11.5 14.7 1.2 17.6 11.8 167 16 164 165 8 0.1 8.3 7.5 10/06/2006 17:50:00 14.9 0.9 16.8 12.6 14.6 0.9 16.4 12.2 15.1 1 17.2 11.5 169 11 170 165 8 0.1 8.3 7 10/06/2006 18:00:00 14.3 1 16.8 10.7 13.9 1 16.4 10.7 14.4 1 16.8 11.1 168 13 165 165 7.8 0.2 8.3 7.3 10/06/2006 18:10:00 13.9 0.9 16.1 11.1 13.6 0.9 16.8 10.7 13.8 1 16.8 11.5 168 11 163 165 7.8 0.2 8.3 7.3 10/06/2006 18:20:00 14.2 0.9 16.8 10.7 13.9 0.9 16.1 10.7 14.1 1 16.4 11.1 165 8 165 165 7.9 0.2 8.3 7.3 10/06/2006 18:30:00 13.4 0.8 15.3 11.1 13.1 0.7 15.3 11.1 13.5 0.8 15.3 11.5 167 16 146 165 7.9 0.2 8.3 7.3 10/06/2006 18:40:00 13.5 1 16.1 10.7 13.3 1 15.6 10.7 13.3 1 15.6 10.3 167 13 176 165 7.9 0.2 8.3 7.3 10/06/2006 18:50:00 13.3 1 16.1 10.7 13.1 1 15.6 11.1 13.1 1 15.3 10.3 164 15 165 165 8 0.2 8.3 7.5 10/06/2006 19:00:00 13.4 0.8 14.9 10.7 13.2 0.7 14.9 11.1 13.3 0.9 15.3 10.7 163 10 163 165 8 0.2 8.3 7.5 10/06/2006 19:10:00 12.3 0.9 14.5 10.7 12.1 0.9 14.5 10.3 12.4 1 14.9 9.9 165 11 165 165 7.9 0.2 8.3 7.3 10/06/2006 19:20:00 10.4 1 12.2 8.4 10.2 0.9 11.8 8 10.4 1 12.2 8 162 6 166 165 7.9 0.2 8 7.3 10/06/2006 19:30:00 11.4 1.2 14.1 8.8 11.2 1.2 14.1 8.4 11.6 1.2 14.1 9.1 158 5 157 165 7.8 0.2 8 7.3 10/06/2006 19:40:00 12 0.8 14.1 9.9 11.9 0.8 13.7 10.3 12.2 0.9 14.5 9.9 160 6 136 165 7.8 0.3 8 7.3 10/06/2006 19:50:00 12.3 0.8 14.1 10.3 12.1 0.7 14.1 10.3 12.2 1 14.1 9.5 164 7 165 165 7.8 0.2 8.3 7.3 10/06/2006 20:00:00 14.4 1.1 16.8 11.5 14.1 1 16.4 11.5 14.4 1 16.4 11.5 166 13 167 165 7.9 0.2 8.3 7.3 10/06/2006 20:10:00 13.9 0.9 16.1 11.5 13.7 0.8 15.6 11.5 14.1 0.9 15.6 11.8 163 16 165 165 8 0.1 8.3 7.5 10/06/2006 20:20:00 13.2 0.6 14.9 11.5 13.1 0.5 14.9 11.5 13.1 0.7 14.9 10.7 163 12 164 165 8 0.1 8.3 7.5 10/06/2006 20:30:00 12.8 0.8 14.5 10.3 12.6 0.7 14.1 10.7 12.7 0.8 14.5 10.3 162 11 158 165 8 0 8.3 7.5 10/06/2006 20:40:00 13.3 0.7 15.3 10.7 13.2 0.7 14.9 10.7 13.1 0.8 15.3 11.1 163 13 159 165 8.1 0 8.3 7.5 10/06/2006 20:50:00 13.8 1.1 16.1 11.1 13.7 1 15.6 11.1 13.5 1.3 15.6 9.9 163 15 168 165 8 0.1 8.3 7.5 10/06/2006 21:00:00 13.9 1 16.1 11.5 13.7 0.8 15.6 11.5 13.6 1 15.6 11.1 162 11 164 165 8 0.1 8.3 7.5 10/06/2006 21:10:00 13.8 0.9 16.1 10.7 13.7 0.9 15.6 11.1 13.7 1.1 16.1 10.7 162 19 165 165 8 0.1 8.3 7.5 10/06/2006 21:20:00 13.4 0.9 16.1 11.1 13.2 0.8 15.3 11.1 13.3 0.8 15.6 11.1 163 9 165 165 8 0.1 8.3 7.5 10/06/2006 21:30:00 13.1 0.9 15.3 10.3 12.8 0.8 14.5 9.9 13 1.1 15.3 9.9 166 8 173 165 8 0.1 8.3 7.5 10/06/2006 21:40:00 13 0.7 14.5 11.1 12.8 0.6 14.5 10.7 12.8 0.9 14.9 10.3 164 13 168 165 8 0.1 8.3 7.5 10/06/2006 21:50:00 10.7 1.2 13 8 10.6 1.1 13 7.6 10.7 1.2 13 6.8 162 13 162 165 8 0.1 8.3 7.5 10/06/2006 22:00:00 9.5 0.7 11.1 7.6 9.3 0.7 10.7 7.6 9.4 0.8 11.5 7.6 160 4 156 165 8 0.1 8.3 7.5 10/06/2006 22:10:00 9.4 0.9 11.5 7.6 9.4 0.8 11.1 7.6 9.6 0.9 11.5 7.2 156 4 153 165 8 0.1 8.3 7.5 10/06/2006 22:20:00 9.6 0.4 10.7 8.4 9.6 0.4 10.7 8.4 9.6 0.6 11.8 7.6 156 4 150 165 7.9 0.2 8 7.3 10/06/2006 22:30:00 10.3 0.5 12.2 9.1 10.2 0.5 11.8 8.8 10.4 0.5 12.2 9.1 157 2 157 165 8 0.2 8.3 7.3 10/06/2006 22:40:00 10.4 0.9 12.6 8.4 10.3 0.9 12.2 8.4 10.5 0.9 12.6 8.8 155 3 155 165 7.9 0.2 8.3 7.3 10/06/2006 22:50:00 13.4 1.1 15.6 10.7 13.3 1.1 15.6 10.7 13.5 1.2 16.1 10.7 155 3 160 165 8.3 0.2 8.5 7.8 10/06/2006 23:00:00 13.2 1 15.3 11.5 13.1 1 15.3 11.5 13.5 0.9 15.3 11.5 157 3 160 165 8.3 0.2 8.5 7.8 10/06/2006 23:10:00 11.9 0.6 13.7 9.9 11.7 0.6 13.3 9.5 12.2 0.6 13.7 10.3 158 4 156 165 8.2 0.1 8.5 7.5 10/06/2006 23:20:00 11.4 0.6 13 9.1 11.3 0.6 12.6 9.1 11.5 0.6 13 9.1 161 11 170 165 8.1 0.1 8.3 7.8 10/06/2006 23:30:00 12.3 0.6 13.3 10.3 12.1 0.6 13.3 10.3 12.5 0.7 13.7 10.3 168 16 165 165 8 0.1 8.3 7.5 10/06/2006 23:40:00 12.2 0.6 13.7 10.3 12 0.6 13.7 9.9 12.1 0.7 13.7 10.3 165 8 172 165 8 0.1 8.3 7.5 10/06/2006 23:50:00 12.1 0.6 13.7 9.9 11.9 0.6 13.3 9.9 12 0.7 13.7 9.9 164 15 165 165 8.1 0 8.3 7.5 10/07/2006 00:00:00 9.8 1 12.2 7.2 9.8 1 12.2 7.6 9.9 1.1 13 7.6 161 15 165 165 8.1 0 8.5 7.8 10/07/2006 00:10:00 8.4 0.6 9.9 6.8 8.2 0.6 9.5 6.8 8.4 0.5 9.9 7.2 158 5 163 165 8.1 0 8.5 7.8 10/07/2006 00:20:00 8.5 0.6 10.7 6.8 8.4 0.6 10.3 6.8 8.6 0.6 10.7 6.8 158 4 158 165 8.1 0.1 8.5 7.5 10/07/2006 00:30:00 7.9 0.7 10.3 6.1 7.7 0.7 9.9 6.1 7.9 0.7 9.5 6.1 156 5 157 165 8 0.1 8.3 7.8 10/07/2006 00:40:00 8.2 1.1 11.8 6.8 8.2 1.1 11.8 6.8 8.4 1.2 12.6 6.8 152 3 148 165 8.1 0.1 8.5 7.5 10/07/2006 00:50:00 9.9 1.2 12.2 7.6 9.9 1.2 11.8 7.2 10 1.2 12.2 7.6 156 4 154 165 8.4 0.2 8.5 7.8 10/07/2006 01:00:00 9.9 0.7 12.2 8.4 9.7 0.7 11.8 8.4 10 0.6 12.2 8.4 157 5 162 165 8.3 0 8.5 7.8 10/07/2006 01:10:00 12.5 1 14.5 10.3 12.3 0.9 14.1 10.3 12.4 1 14.5 9.9 166 20 169 165 8.3 0 8.5 7.8 10/07/2006 01:20:00 13.9 1 16.4 11.1 13.7 0.9 16.1 11.1 13.6 1.1 17.2 10.7 162 5 151 165 8.4 0.1 8.5 7.8 10/07/2006 01:30:00 15 1.1 17.6 11.8 14.7 1.1 17.6 12.2 14.8 1.3 17.6 11.5 165 12 166 165 8.5 0.1 8.8 8 10/07/2006 01:40:00 14.1 1 16.4 11.5 13.9 0.9 16.1 11.5 14 1 16.4 11.5 166 8 166 165 8.3 0 8.5 7.8 10/07/2006 01:50:00 15 0.8 17.2 11.5 14.7 0.7 16.4 11.8 14.9 0.9 16.8 12.2 167 10 165 165 8.3 0 8.5 7.8 10/07/2006 02:00:00 14.5 1.2 17.2 11.8 14.2 1.1 16.8 11.1 14.4 1.2 17.2 11.8 167 13 165 165 8.3 0 8.5 7.8 10/07/2006 02:10:00 14.9 1.1 17.2 11.1 14.7 1.1 16.8 11.5 14.8 1.2 17.2 10.7 163 13 165 165 8.3 0 8.5 8 10/07/2006 02:20:00 13.9 0.8 15.6 11.8 13.7 0.8 15.6 11.5 13.8 0.9 16.1 11.1 165 18 165 165 8.3 0.1 8.5 7.8 10/07/2006 02:30:00 13.1 0.7 15.3 11.5 12.9 0.7 14.9 11.1 13 0.8 15.3 11.1 163 17 175 165 8.4 0.1 8.5 8 10/07/2006 02:40:00 13.5 1 16.8 10.7 13.4 1 16.4 11.1 13.3 1.1 16.1 10.3 162 20 161 165 8.5 0.1 8.5 8 10/07/2006 02:50:00 14.1 1 16.4 11.1 13.9 1 16.4 11.1 14.1 1 17.2 11.5 162 11 162 165 8.5 0.1 8.5 7.8 10/07/2006 03:00:00 13.5 0.9 15.3 11.1 13.3 0.8 15.3 11.1 13.4 1.1 15.6 10.3 163 11 166 165 8.5 0.1 8.5 8 10/07/2006 03:10:00 13.1 0.9 14.9 10.3 12.9 0.9 14.9 9.9 13.2 0.9 15.3 10.7 163 13 154 165 8.4 0.2 8.5 7.8 10/07/2006 03:20:00 12.1 0.7 13.7 10.3 11.9 0.7 13.3 9.9 12.2 0.8 13.7 9.5 166 12 166 165 8.4 0.2 8.5 8 10/07/2006 03:30:00 10.8 1 12.6 8.4 10.6 0.9 12.2 8 10.7 1.1 12.6 8 164 16 168 165 8.4 0.2 8.5 7.8 10/07/2006 03:40:00 8.1 0.8 9.9 6.5 8.1 0.8 9.9 6.5 8.4 0.8 10.7 6.5 159 4 162 165 8.3 0.2 8.5 7.8 10/07/2006 03:50:00 8.8 0.7 10.7 7.2 8.7 0.7 10.7 6.8 9 0.7 10.7 7.2 157 5 163 165 8.3 0.2 8.5 7.8 10/07/2006 04:00:00 9.6 1 11.8 7.6 9.5 1 11.8 7.2 9.7 0.9 11.8 6.8 156 5 150 165 8.3 0.1 8.5 7.8 10/07/2006 04:10:00 12.3 1 14.5 10.3 12.2 1 14.1 10.3 12.3 1.2 14.9 9.9 154 3 155 165 8.4 0.2 8.5 7.8 10/07/2006 04:20:00 13.6 0.5 14.5 11.8 13.5 0.5 14.5 11.5 13.8 0.6 15.3 11.5 155 2 156 165 8.5 0.1 8.8 8 10/07/2006 04:30:00 12.7 0.4 13.7 11.5 12.7 0.4 13.7 11.5 12.6 0.5 13.7 10.7 152 2 155 165 8.6 0 8.8 8.3 10/07/2006 04:40:00 13.3 0.8 15.3 11.5 13.2 0.8 14.9 11.5 13.1 0.9 15.3 11.1 152 3 153 165 8.7 0 8.8 8.3 10/07/2006 04:50:00 14.7 0.5 16.1 13 14.6 0.5 15.6 13 14.5 0.7 16.1 12.2 154 2 151 165 8.7 0 9 8.3 10/07/2006 05:00:00 13.7 0.5 14.9 11.8 13.7 0.5 15.3 11.8 13.4 0.7 15.3 11.1 152 2 155 165 8.7 0 9 8.5 10/07/2006 05:10:00 13.9 0.9 15.6 11.5 13.9 0.8 15.6 11.1 13.6 1 16.1 11.1 150 3 150 165 8.7 0 9 8.3 10/07/2006 05:20:00 12.8 1.1 15.3 10.3 12.9 1 15.3 10.7 12.5 1.3 14.9 8 147 4 145 165 8.7 0 9 8.3 10/07/2006 05:30:00 11.1 0.8 13 9.1 11.1 0.8 13 9.1 10.7 0.8 13 8.8 149 4 151 165 8.7 0 9 8.5 10/07/2006 05:40:00 12.1 0.8 14.5 9.5 12 0.8 14.5 9.5 11.7 1 15.6 8 151 3 151 165 8.9 0 9 8.3 10/07/2006 05:50:00 12.8 0.6 14.5 10.7 12.8 0.6 14.5 10.7 12.6 0.7 14.1 10.7 151 3 150 165 8.9 0 9 8.5 10/07/2006 06:00:00 13.1 0.7 14.9 11.1 13.1 0.7 14.9 11.1 12.8 0.8 14.5 10.3 151 3 156 165 8.9 0 9 8.8 10/07/2006 06:10:00 13.3 0.7 14.9 11.1 13.2 0.7 15.6 11.5 13.1 0.7 14.9 10.7 154 3 154 165 9 0 9 8.8 10/07/2006 06:20:00 13 0.6 14.5 11.1 12.8 0.5 14.5 11.5 12.8 0.7 14.5 10.7 154 3 156 165 9 0 9 8.8 10/07/2006 06:30:00 13 0.7 14.9 10.7 12.9 0.7 14.9 11.1 13 0.7 14.9 11.1 155 3 153 165 9 0 9 8.8 10/07/2006 06:40:00 12.6 0.9 14.1 10.3 12.4 0.9 14.1 10.3 12.7 0.9 14.5 10.7 156 2 156 165 9 0 9.3 8.8 10/07/2006 06:50:00 12.3 0.5 13.7 10.7 12.2 0.5 13.7 10.7 12.6 0.5 13.7 10.7 155 2 151 165 9.1 0 9.3 8.8 10/07/2006 07:00:00 13.4 0.7 14.9 11.5 13.2 0.7 14.9 11.5 13.6 0.7 15.3 11.8 157 3 159 165 9.2 0 9.3 8.5 10/07/2006 07:10:00 13.8 0.7 15.3 11.5 13.6 0.7 15.3 11.8 13.9 0.7 15.6 11.8 156 5 160 165 9.2 0 9.3 9 10/07/2006 07:20:00 11.6 1.5 14.5 8.4 11.4 1.5 14.1 8 11.9 1.4 14.9 8.8 158 5 158 165 9.2 0 9.3 9 10/07/2006 07:30:00 10 0.6 11.5 8.4 9.8 0.5 11.1 8.4 10.1 0.6 11.8 8.8 163 15 162 165 9.3 0 9.3 8.8 10/07/2006 07:40:00 10.6 0.6 12.6 9.1 10.4 0.6 12.2 8.8 10.5 0.7 12.2 8.4 164 12 170 165 9.3 0 9.6 8.8 10/07/2006 07:50:00 12 1 14.1 9.9 11.8 0.9 13.7 9.5 12 1 14.5 9.9 168 6 169 165 9.4 0.1 9.8 8.8 10/07/2006 08:00:00 13.8 0.8 15.6 11.8 13.4 0.8 15.3 11.8 13.7 0.9 15.6 11.5 167 9 166 165 9.4 0.3 9.8 8.8 10/07/2006 08:10:00 14.9 0.7 16.8 13 14.6 0.7 16.4 13 15.1 0.7 16.8 13 167 10 169 165 9.4 0.3 9.8 8.8 10/07/2006 08:20:00 14.9 0.8 16.8 13 14.4 0.7 16.4 12.6 14.9 0.8 17.6 13 171 4 181 165 9.4 0.3 9.8 8.8 10/07/2006 08:30:00 15.2 0.7 17.2 13 14.8 0.7 16.8 12.2 15.4 0.8 17.6 13 171 6 178 165 9.4 0.3 9.8 9 10/07/2006 08:40:00 15.7 1.1 18.3 12.6 15.2 1 17.6 12.2 15.7 1 18.3 13.3 168 6 165 165 9.4 0.3 9.8 9 10/07/2006 08:50:00 16.7 1 18.7 14.1 16.3 0.9 18.3 14.1 16.6 1 19.1 13.3 172 15 178 165 9.4 0.3 9.8 9 10/07/2006 09:00:00 16.4 0.8 18.3 14.5 15.9 0.8 17.6 13.7 16.5 0.9 18.7 14.5 171 5 173 165 9.4 0.3 9.8 9 10/07/2006 09:10:00 15.8 0.7 17.6 14.1 15.3 0.6 16.8 13.7 15.9 0.9 17.9 12.2 169 4 162 165 9.5 0.3 9.8 9 10/07/2006 09:20:00 15.3 0.8 17.2 12.6 14.9 0.7 16.8 12.6 15.4 0.8 17.9 12.2 169 11 169 165 9.5 0.2 9.8 9 10/07/2006 09:30:00 14.5 1 17.2 11.8 14.2 0.9 16.8 11.8 14.3 1.1 16.8 11.5 166 9 165 165 9.4 0.3 9.8 8.8 10/07/2006 09:40:00 14.1 0.7 15.6 11.8 13.8 0.6 15.3 11.8 14.1 0.8 16.1 11.8 167 9 166 165 9.4 0.3 9.8 8.8 10/07/2006 09:50:00 13.5 0.6 14.9 11.8 13.3 0.5 14.5 11.8 13.5 0.8 15.3 11.1 166 6 167 165 9.4 0.3 9.6 8.8 10/07/2006 10:00:00 13.4 0.4 14.1 11.1 13.1 0.4 13.7 11.5 13.4 0.5 14.5 11.5 164 12 164 165 9.4 0.3 9.6 8.8 10/07/2006 10:10:00 12.9 0.8 14.1 10.3 12.7 0.7 13.7 10.7 12.9 0.8 14.5 10.3 162 15 165 165 9.4 0.3 9.6 8.8 10/07/2006 10:20:00 13.4 0.5 14.9 12.6 13.2 0.5 14.9 12.2 13.6 0.5 15.3 12.2 164 13 165 165 9.3 0.3 9.6 8.8 10/07/2006 10:30:00 13.3 0.7 15.3 11.1 13.1 0.7 14.9 11.1 13.3 0.7 15.3 11.1 166 14 165 165 9.3 0.3 9.6 8.8 10/07/2006 10:40:00 12.5 0.6 13.7 10.7 12.3 0.5 13.3 10.7 12.6 0.6 14.1 10.7 162 11 167 165 9.4 0.3 9.8 8.8 10/07/2006 10:50:00 10.6 0.6 12.2 9.1 10.4 0.6 11.8 9.1 10.8 0.6 12.6 9.1 160 4 153 165 9.3 0.3 9.6 8.8 10/07/2006 11:00:00 10.4 0.4 11.5 9.1 10.2 0.4 11.5 9.1 10.5 0.5 11.5 9.1 162 12 164 165 9.2 0.3 9.6 8.5 10/07/2006 11:10:00 10.2 0.6 11.8 8.8 10 0.6 11.5 8.4 10.4 0.6 11.8 8.8 161 3 160 165 9.3 0.3 9.6 8.8 10/07/2006 11:20:00 10.4 0.5 11.5 8.8 10.2 0.5 11.5 8.4 10.6 0.5 11.8 9.1 162 9 164 165 9.3 0.3 9.6 8.8 10/07/2006 11:30:00 10.1 0.6 11.8 8.8 9.9 0.6 11.8 8.4 10.2 0.6 12.2 8.4 162 5 172 165 9.3 0.3 9.6 8.8 10/07/2006 11:40:00 11.8 1 14.9 8 11.6 1 14.9 8.4 11.8 1.1 14.9 9.5 165 9 167 165 9.3 0.3 9.6 8.8 10/07/2006 11:50:00 13.5 0.7 15.3 11.5 13.3 0.7 14.9 11.1 13.5 0.8 15.6 11.1 167 11 158 165 9.4 0.3 9.6 8.8 10/07/2006 12:00:00 14 0.7 16.1 11.8 13.7 0.6 15.3 11.5 14 0.7 15.6 11.8 168 9 174 165 9.4 0.3 9.6 9 10/07/2006 12:10:00 13.7 0.8 15.6 10.7 13.4 0.7 15.3 10.7 13.7 0.8 15.6 10.7 167 11 170 165 9.4 0.3 10.1 8.8 10/07/2006 12:20:00 12.6 0.8 14.5 10.7 12.4 0.8 14.5 10.7 12.5 0.8 14.5 10.3 167 16 169 165 9.4 0.2 9.6 9 10/07/2006 12:30:00 10.8 0.8 12.6 8.4 10.7 0.7 12.2 8.4 10.8 0.8 13 8.8 163 16 165 165 9.3 0.2 9.6 8.8 10/07/2006 12:40:00 11.1 0.7 12.6 8.8 10.9 0.7 12.6 8.8 11.3 0.8 13 9.1 161 7 157 165 9.3 0.2 9.6 8.8 10/07/2006 12:50:00 10.9 0.7 12.6 8.8 10.8 0.6 12.2 8.8 11.1 0.7 13 8.4 162 13 165 165 9.4 0.2 9.6 8.8 10/07/2006 13:00:00 11.3 0.6 12.6 9.5 11.1 0.6 12.2 8.8 11.5 0.6 13.3 9.9 162 10 162 165 9.3 0.2 9.6 8.8 10/07/2006 13:10:00 11.3 0.8 13 8.8 11.1 0.7 13 8.8 11.5 0.7 13.3 9.5 160 12 159 165 9.2 0.2 9.6 8.8 10/07/2006 13:20:00 11.7 0.8 14.1 9.9 11.6 0.7 14.5 10.3 12 0.7 14.1 9.9 158 5 164 165 9.3 0.2 9.6 8.8 10/07/2006 13:30:00 11.7 0.8 13.7 9.9 11.5 0.8 14.1 9.5 11.9 0.7 14.1 10.3 158 5 161 165 9.2 0.2 9.6 8.8 10/07/2006 13:40:00 10.9 0.6 13 9.1 10.7 0.6 12.6 9.1 11.1 0.7 13 9.1 159 7 158 165 9 0.3 9.6 8.5 10/07/2006 13:50:00 9.2 0.5 10.7 8 9.1 0.5 10.3 8 9.3 0.6 11.1 7.2 156 7 158 165 9.1 0.2 9.3 8.5 10/07/2006 14:00:00 9.8 0.6 11.8 8.4 9.8 0.6 11.5 8.4 9.9 0.7 11.5 8.4 155 3 156 165 9 0.3 9.6 8.5 10/07/2006 14:10:00 10.8 0.6 13 8.8 10.7 0.5 12.2 8.4 11.1 0.5 13 9.5 158 3 160 165 9 0.2 9.3 8.5 10/07/2006 14:20:00 10.9 0.7 12.6 9.1 10.8 0.6 12.2 9.1 11.1 0.7 13 9.5 159 8 154 165 9.2 0.2 9.6 8.8 10/07/2006 14:30:00 11.3 0.7 13.3 9.9 11.2 0.7 13 9.9 11.5 0.7 13.7 9.9 158 3 156 165 9.2 0.2 9.6 8.8 10/07/2006 14:40:00 12.8 0.8 15.6 11.1 12.6 0.7 15.3 10.7 12.8 0.7 15.3 11.1 157 3 159 165 9 0.3 9.6 8.5 10/07/2006 14:50:00 15.2 0.9 17.6 12.6 15.1 0.9 17.2 12.6 15.3 1 17.6 12.2 156 3 155 165 9 0.2 9.3 8.5 10/07/2006 15:00:00 15.1 0.9 17.2 12.6 14.9 0.9 17.2 12.6 15.3 0.9 17.6 13 158 3 157 165 9.1 0.1 9.6 8.8 10/07/2006 15:10:00 13.9 0.5 15.6 12.6 13.8 0.5 15.3 12.6 14.1 0.6 15.3 12.2 155 2 151 165 9 0.2 9.3 8.5 10/07/2006 15:20:00 13.7 0.7 15.6 11.8 13.5 0.6 15.3 11.5 13.9 0.8 15.6 12.2 157 3 157 165 9 0.2 9.3 8.5 10/07/2006 15:30:00 12.9 0.5 14.1 11.5 12.8 0.5 14.1 11.5 13.1 0.6 14.1 10.7 155 3 156 165 9 0.1 9.3 8.5 10/07/2006 15:40:00 12.9 0.6 14.5 11.1 12.8 0.5 14.5 11.1 12.9 0.6 14.1 11.1 153 3 153 165 9 0.1 9.3 8.8 10/07/2006 15:50:00 12.6 0.6 14.1 11.1 12.5 0.6 14.1 11.1 12.7 0.6 14.1 11.1 154 3 156 165 9 0.1 9.3 8.5 10/07/2006 16:00:00 12.3 0.7 14.1 10.3 12.2 0.7 14.1 10.3 12.3 0.7 14.1 9.9 154 3 153 165 9 0.1 9.3 8.8 10/07/2006 16:10:00 11.5 0.5 13 10.3 11.5 0.5 12.6 10.3 11.6 0.6 13 10.3 153 3 150 165 9 0.1 9.3 8.8 10/07/2006 16:20:00 11.7 0.5 13 10.3 11.6 0.5 13 10.3 11.9 0.5 13.3 10.7 152 3 148 165 9 0.1 9.3 8.5 10/07/2006 16:30:00 11.5 0.5 12.6 9.9 11.4 0.5 12.6 9.9 11.5 0.5 13 10.3 152 3 151 165 9 0.1 9.3 8.5 10/07/2006 16:40:00 11.9 0.4 13 11.1 11.9 0.4 12.6 10.7 12 0.5 13.3 10.7 152 3 151 165 9 0.1 9.3 8.5 10/07/2006 16:50:00 11.7 0.6 13 10.3 11.6 0.5 13.3 10.3 11.6 0.6 13 10.3 150 3 147 165 9 0.1 9.3 8.5 10/07/2006 17:00:00 13.3 0.9 14.9 9.9 13.3 0.9 14.9 10.7 13.1 1 15.3 9.5 149 3 151 165 9 0.1 9.3 8.8 10/07/2006 17:10:00 14.2 0.7 16.1 12.2 14.2 0.7 16.1 12.2 13.8 0.8 15.6 11.1 149 4 155 165 9 0.1 9.3 8.5 10/07/2006 17:20:00 14.8 0.7 16.4 12.2 14.7 0.7 16.4 12.2 14.4 1 16.8 9.9 149 4 149 165 9 0 9.3 8.5 10/07/2006 17:30:00 14.5 0.9 16.8 12.6 14.5 0.9 16.8 12.2 14.2 1 16.8 11.1 149 3 150 165 9 0 9.3 8.5 10/07/2006 17:40:00 14.6 0.9 17.2 11.8 14.7 0.9 16.8 12.2 14.2 1.1 16.4 11.1 145 4 153 165 9 0 9 8.8 10/07/2006 17:50:00 14.3 1.1 16.8 11.1 14.3 1.1 16.4 11.8 13.9 1.2 16.4 10.7 147 4 148 165 8.9 0 9 8.5 10/07/2006 18:00:00 15.1 0.8 17.2 13 15.1 0.8 17.6 13 14.7 0.9 17.2 11.8 147 4 139 165 8.9 0 9.3 8.8 10/07/2006 18:10:00 14.9 0.6 16.4 13 14.9 0.6 16.4 13 14.5 1 16.4 10.3 148 3 145 165 8.9 0 9 8.8 10/07/2006 18:20:00 14.7 1.2 17.9 12.2 14.7 1.2 17.6 12.2 14.4 1.3 17.9 11.1 145 4 147 165 8.9 0 9 8.5 10/07/2006 18:30:00 15.7 1.1 19.1 13 15.7 1.1 19.1 13 15.6 1.1 19.1 13 146 4 145 165 8.8 0 9 8.5 10/07/2006 18:40:00 14.8 0.9 17.2 12.6 14.8 0.9 17.6 12.6 14.6 1 17.2 12.2 145 4 141 165 8.8 0 9 8.5 10/07/2006 18:50:00 15.6 0.8 17.6 13 15.7 0.8 17.6 13.3 15.5 0.9 17.6 11.5 146 4 142 165 8.9 0 9 8.5 10/07/2006 19:00:00 15.3 1 17.9 13 15.3 0.9 17.6 13.3 15 1 17.6 11.5 145 4 143 165 8.9 0 9.3 8.5 10/07/2006 19:10:00 16.3 0.9 18.3 13.7 16.3 0.8 18.3 13.7 16 1 18.3 11.5 146 3 148 165 8.9 0 9 8.5 10/07/2006 19:20:00 15.8 0.8 17.6 13.7 15.8 0.8 17.2 13.7 15.5 0.8 17.6 13.3 147 3 145 165 8.8 0 9 8.5 10/07/2006 19:30:00 17.1 1.3 19.5 13.3 17.1 1.3 19.9 13 16.8 1.5 20.2 13 145 4 150 165 8.9 0 9 8.5 10/07/2006 19:40:00 16.7 1.1 19.5 13.7 16.8 1.1 19.5 14.1 16.6 1.4 20.2 11.8 145 5 147 165 8.9 0 9 8.8 10/07/2006 19:50:00 16.3 1.3 20.6 12.6 16.4 1.3 20.2 12.6 16.2 1.3 19.1 11.8 143 6 140 165 8.9 0 9 8.8 10/07/2006 20:00:00 15.9 1.2 19.1 12.2 16.1 1.2 19.1 13 15.7 1.2 19.1 13 141 6 139 165 8.9 0 9 8.8 10/07/2006 20:10:00 16.5 1.2 19.1 12.6 16.6 1.3 19.9 13 16.2 1.3 19.5 12.2 141 6 129 165 8.8 0 9 8.5 10/07/2006 20:20:00 16.4 1.4 19.5 11.8 16.5 1.4 19.5 11.8 15.9 1.6 19.1 11.5 141 7 145 165 8.8 0 9 8.5 10/07/2006 20:30:00 16 1.4 20.2 10.7 16.1 1.5 20.2 11.1 15.7 1.6 19.5 11.1 141 7 150 165 8.8 0 9 8.5 10/07/2006 20:40:00 16.7 1.5 20.2 12.2 16.8 1.5 20.2 12.2 16.3 1.7 19.9 11.5 140 5 140 165 8.8 0 9 8.5 10/07/2006 20:50:00 16 1.9 22.6 10.3 16.1 2 22.6 10.7 15.4 2 22.6 10.3 137 8 135 165 8.8 0 9 8.5 10/07/2006 21:00:00 17 1.7 22.1 12.6 17.1 1.7 21.8 12.6 16.6 1.7 20.6 12.2 140 6 142 165 8.9 0 9 8.3 10/07/2006 21:10:00 17.2 1.3 21 13.7 17.3 1.3 21 13 17 1.5 20.6 12.6 142 7 159 165 8.9 0 9 8.5 10/07/2006 21:20:00 17.2 1.5 21 13.3 17.3 1.5 21.4 13.3 17.1 1.6 21.8 13.3 141 6 141 165 8.8 0 9 8.5 10/07/2006 21:30:00 17.6 1.6 21.4 13.3 17.7 1.5 21.8 13.7 17.5 1.7 21.4 12.6 142 6 146 165 8.7 0 9 8.5 10/07/2006 21:40:00 16.4 1.6 20.2 11.5 16.6 1.6 20.6 11.5 16.3 1.7 20.2 10.7 139 6 145 165 8.7 0 8.8 8.5 10/07/2006 21:50:00 17.3 2.1 22.1 12.2 17.4 2 22.1 11.8 16.9 2 21 10.7 138 6 140 165 8.7 0 9 8.5 10/07/2006 22:00:00 17.5 1.5 21.4 13.3 17.6 1.5 21.4 13 17.3 1.5 21.4 13.3 140 7 145 165 8.7 0 9 8.5 10/07/2006 22:10:00 16.7 1.5 20.2 13 16.7 1.5 19.9 13 16.5 1.6 19.9 12.6 142 5 141 165 8.8 0 9 8.5 10/07/2006 22:20:00 14.7 1.5 17.9 11.1 14.8 1.5 17.9 11.1 14.4 1.7 17.9 9.9 140 6 136 165 8.7 0 9 8.5 10/07/2006 22:30:00 15 1.4 18.3 11.8 15.1 1.5 18.7 11.1 14.7 1.6 18.3 10.3 140 7 136 165 8.7 0 9 8.5 10/07/2006 22:40:00 16.1 1.7 22.1 11.8 16.2 1.7 22.1 11.8 15.5 1.9 21.4 10.7 135 8 139 165 8.8 0 9 8.5 10/07/2006 22:50:00 17.2 2 21.8 12.2 17.3 1.9 21.8 12.6 17 2.1 21.8 11.5 140 7 145 165 8.8 0 9 8.5 10/07/2006 23:00:00 16 1.2 19.1 12.2 16.1 1.2 19.9 12.2 15.8 1.4 19.5 11.1 142 7 148 165 8.7 0 9 8.5 10/07/2006 23:10:00 15.8 1.3 19.1 11.8 15.8 1.3 19.5 11.8 15.3 1.3 18.7 11.5 141 7 126 165 8.8 0 9 8.5 10/07/2006 23:20:00 16.4 1.7 20.6 12.6 16.5 1.7 21 12.6 16 1.6 20.2 11.5 141 7 143 165 8.8 0 9 8.5 10/07/2006 23:30:00 16.4 1.6 20.6 13 16.5 1.6 20.6 12.6 16.1 1.7 19.9 11.5 141 5 138 165 8.7 0 9 8.5 10/07/2006 23:40:00 17.5 1.6 21.4 13 17.6 1.5 21.4 13 17.4 1.6 21 12.2 141 6 147 165 8.7 0 8.8 8.5 10/07/2006 23:50:00 17.3 1.8 22.1 12.6 17.4 1.8 21.8 12.6 16.8 1.9 21 11.1 140 8 123 165 8.7 0 8.8 8.5 10/08/2006 00:00:00 18.9 1.7 22.9 14.1 18.9 1.7 22.6 14.1 18.5 1.8 23.3 13.7 140 7 137 165 8.8 0 9 8.5 10/08/2006 00:10:00 17.6 1.4 20.6 12.2 17.7 1.4 21.4 11.8 17.2 1.5 20.6 13.3 140 7 141 165 8.8 0 9 8.5 10/08/2006 00:20:00 17.6 1.4 20.6 13.7 17.7 1.4 21 13 17.2 1.5 20.6 12.2 139 6 143 165 8.8 0 9 8.5 10/08/2006 00:30:00 16.5 1.7 20.6 12.2 16.6 1.7 21.4 11.8 16.2 1.7 19.9 12.2 140 6 142 165 8.7 0 9 8.5 10/08/2006 00:40:00 14.7 1.3 17.9 11.8 14.7 1.3 17.9 11.8 14.5 1.2 18.7 10.3 141 6 155 165 8.7 0 9 8.3 10/08/2006 00:50:00 17.5 1.5 21.8 13 17.5 1.5 21.4 13 17.1 1.7 21 12.6 141 7 143 165 8.8 0 9 8.5 10/08/2006 01:00:00 15.8 1.4 19.5 11.8 15.9 1.5 19.5 12.2 15.7 1.5 20.6 12.2 140 6 154 165 8.9 0 9.3 8.5 10/08/2006 01:10:00 16.8 1.4 20.6 13 16.9 1.5 20.6 13 16.4 1.4 20.6 12.6 138 7 142 165 8.9 0 9 8.8 10/08/2006 01:20:00 18.2 1.8 23.3 13.7 18.2 1.9 22.9 14.1 17.8 2 23.7 13.3 140 6 145 165 8.9 0 9 8.5 10/08/2006 01:30:00 18.4 1.7 23.3 13.7 18.5 1.8 23.7 13.7 18 1.8 23.3 13.7 138 7 143 165 8.9 0 9 8.5 10/08/2006 01:40:00 18 1.5 21.8 13.7 18.2 1.5 22.1 14.1 17.5 1.7 23.3 12.6 136 6 135 165 8.9 0 9 8.5 10/08/2006 01:50:00 17.5 1.5 22.1 12.6 17.5 1.5 22.6 13 17.3 1.6 21.4 12.2 139 6 136 165 8.9 0 9 8.5 10/08/2006 02:00:00 17 1.5 21 12.6 17.1 1.5 21.4 12.6 16.6 1.7 21 12.2 137 6 113 165 8.9 0 9.3 8.5 10/08/2006 02:10:00 15.7 1.6 20.2 12.2 15.7 1.7 20.2 11.8 15.6 1.7 21.4 10.3 143 6 135 165 8.8 0 9 8.5 10/08/2006 02:20:00 16.4 1.5 20.2 11.8 16.5 1.5 19.9 11.1 16.1 1.7 20.2 11.1 140 7 145 165 8.8 0 9 8.5 10/08/2006 02:30:00 17.7 1.4 21.4 12.6 17.8 1.4 21.8 12.2 17.7 1.7 21 12.2 141 6 139 165 8.9 0 9 8.5 10/08/2006 02:40:00 16.2 1.7 20.2 11.5 16.3 1.7 20.6 11.5 15.9 1.7 20.6 11.5 138 7 132 165 8.9 0 9 8.5 10/08/2006 02:50:00 16.9 1.7 21.4 12.2 17.1 1.7 21 12.2 16.7 2 20.6 11.1 135 7 142 165 8.9 0 9 8.5 10/08/2006 03:00:00 16.5 1.8 21.8 11.1 16.7 1.9 21.4 11.1 16.3 1.9 22.1 11.1 136 8 145 165 8.9 0 9 8.8 10/08/2006 03:10:00 17 1.7 21.4 12.2 17.2 1.8 21.4 13 16.6 2 22.1 11.5 134 8 140 165 8.9 0 9 8.8 10/08/2006 03:20:00 16.9 1.7 21.4 12.2 17 1.8 21.4 11.5 16.4 1.8 21.8 11.1 135 7 143 165 8.9 0 9 8.8 10/08/2006 03:30:00 16.9 1.7 22.1 10.3 17.1 1.7 22.1 9.1 16.7 1.8 21.8 10.7 136 7 131 165 8.9 0 9 8.5 10/08/2006 03:40:00 16.6 1.7 20.2 13 16.8 1.7 21 12.6 16.2 2 21 11.1 132 7 137 165 8.9 0 9 8.8 10/08/2006 03:50:00 16.3 1.7 21 11.5 16.5 1.7 21.4 11.8 16.1 2 21.4 9.9 129 7 128 165 9 0 9 8.8 10/08/2006 04:00:00 15.2 1.4 19.1 10.3 15.4 1.4 19.5 10.7 14.7 1.5 19.1 10.7 130 7 125 165 9 0 9.3 8.8 10/08/2006 04:10:00 16.5 2.2 22.6 11.5 16.7 2.2 22.6 11.1 16.1 2.3 22.1 10.7 127 7 127 165 9 0 9 8.8 10/08/2006 04:20:00 16.8 2 22.1 11.1 17.1 2 22.1 10.7 16.7 2.2 22.1 11.1 126 7 125 165 9 0 9.3 8.8 10/08/2006 04:30:00 16.9 1.9 22.1 12.2 17.2 1.9 22.1 12.6 16.5 1.9 23.3 11.1 124 6 128 165 9 0 9 8.8 10/08/2006 04:40:00 16.5 2 22.1 11.1 16.8 2 22.9 11.5 16.1 2.1 22.6 9.9 125 6 123 165 9 0 9 8.8 10/08/2006 04:50:00 16.9 2 22.1 11.5 17.2 2.1 22.9 11.5 16.5 2.3 21.8 10.3 123 8 128 165 9 0 9.3 8.8 10/08/2006 05:00:00 17.5 2.2 25.2 12.2 17.8 2.2 25.6 12.2 17 2.2 24.4 11.5 124 7 123 165 9 0 9.3 8.8 10/08/2006 05:10:00 15.8 2.2 21 9.9 16 2.2 21 9.9 15.3 2.3 21 10.3 126 8 128 165 9 0 9.3 8.8 10/08/2006 05:20:00 17.4 2.2 22.6 11.5 17.7 2.2 23.3 11.5 17 2.4 22.9 9.9 126 7 128 165 9 0 9.3 8.5 10/08/2006 05:30:00 17.6 1.7 22.1 12.6 17.9 1.7 22.1 12.6 17.2 1.7 21.8 13 124 7 124 165 9 0.1 9.3 8.5 10/08/2006 05:40:00 16.9 1.9 23.7 12.6 17.2 1.9 24 12.6 16.6 1.8 21.8 12.2 124 7 130 165 9 0 9.3 8.5 10/08/2006 05:50:00 16.6 1.9 22.9 11.8 16.9 1.9 23.3 11.8 16.2 2.1 24 10.7 122 6 111 165 9 0 9.3 8.5 10/08/2006 06:00:00 16.4 2.2 22.6 10.7 16.7 2.2 22.9 11.5 16 2.2 23.3 10.7 123 6 121 165 9 0 9.3 8.8 10/08/2006 06:10:00 16.4 2.3 21.4 9.9 16.7 2.3 21.8 9.9 16 2.4 21.8 9.1 124 6 129 165 9.1 0.1 9.3 8.5 10/08/2006 06:20:00 15.5 1.9 21.4 10.7 15.8 2 21.8 10.3 15.1 2.1 21 9.9 121 8 125 165 9.1 0 9.3 8.5 10/08/2006 06:30:00 16.5 1.9 22.1 11.8 16.8 1.9 22.9 11.1 16.2 1.8 22.1 10.7 123 8 123 165 9.1 0 9.3 8.8 10/08/2006 06:40:00 17.5 1.9 24 11.1 17.8 1.9 24 11.5 17.1 2.1 22.1 10.7 124 7 120 165 9.2 0 9.3 8.8 10/08/2006 06:50:00 16.1 2 22.9 9.9 16.4 2.1 23.3 9.9 15.8 2.1 23.7 9.5 123 7 123 165 9.2 0 9.3 8.8 10/08/2006 07:00:00 17 1.9 21 12.6 17.3 1.9 21.4 13.3 16.4 1.9 21 11.5 122 7 118 165 9.2 0 9.3 9 10/08/2006 07:10:00 17.2 2.2 23.3 11.8 17.5 2.3 23.3 11.8 16.5 2.2 21.4 11.5 119 7 116 165 9.2 0 9.6 8.8 10/08/2006 07:20:00 16.4 1.8 21 11.5 16.7 1.9 21.4 11.8 15.6 2.1 21.4 9.9 116 8 121 165 9.2 0 9.3 8.8 10/08/2006 07:30:00 16.9 2.1 23.3 11.8 17.2 2.2 24.8 11.8 16.1 2.5 24.4 10.7 116 8 108 165 9.2 0 9.3 8.8 10/08/2006 07:40:00 16.8 2.4 23.7 9.5 17.1 2.4 23.7 9.5 16.1 2.6 22.9 9.5 116 8 117 165 9.2 0 9.6 8.8 10/08/2006 07:50:00 17.3 2.2 22.9 10.3 17.5 2.3 23.7 9.9 16.2 2.4 22.6 10.3 113 7 115 165 9.2 0 9.6 8.8 10/08/2006 08:00:00 17.5 2 22.1 12.2 17.8 2.1 22.9 12.2 16.3 2.3 22.1 10.7 109 7 99 165 9.2 0 9.6 8.8 10/08/2006 08:10:00 17.5 2.1 23.3 11.5 17.8 2.1 23.3 11.5 16.7 2.1 22.6 10.7 109 7 107 165 9.2 0 9.6 8.8 10/08/2006 08:20:00 17.6 1.7 21.8 12.2 18 1.7 21.8 12.2 16.7 2.1 21.8 11.1 112 7 110 165 9.2 0 9.6 8.8 10/08/2006 08:30:00 16.4 1.8 20.6 11.8 16.7 1.9 21 11.8 15.5 2.2 21 10.7 113 7 105 165 9.3 0 9.6 8.8 10/08/2006 08:40:00 17.1 2.2 23.3 11.5 17.4 2.2 23.3 11.8 16.2 2.2 22.6 11.5 117 7 122 165 9.2 0.2 9.6 8.8 10/08/2006 08:50:00 17.3 1.7 21.8 13.7 17.5 1.7 22.9 13.7 16.6 1.8 21.4 11.8 117 7 102 165 9.2 0.2 9.6 8.8 10/08/2006 09:00:00 17.1 2.1 22.9 11.1 17.4 2.2 23.7 10.3 16.4 2.2 22.1 9.9 117 8 116 165 9.2 0.3 9.6 8.8 10/08/2006 09:10:00 16.9 1.7 22.6 11.8 17.2 1.7 22.6 11.5 16.2 1.7 20.6 10.3 116 7 127 165 9.3 0.3 9.6 8.8 10/08/2006 09:20:00 16.5 1.9 22.6 10.3 16.8 2 22.6 11.1 15.6 2.1 21.8 9.9 113 9 118 165 9.3 0.3 9.6 8.8 10/08/2006 09:30:00 17 1.7 21.8 13 17.3 1.7 21.4 12.2 16.1 1.9 21.4 11.1 111 7 109 165 9.3 0.3 9.6 8.8 10/08/2006 09:40:00 17.3 2 21.8 12.6 17.5 2 21.8 13 16.2 2.2 22.1 11.5 107 7 99 165 9.4 0.3 9.6 8.8 10/08/2006 09:50:00 16.8 1.7 21 10.7 17.1 1.7 21.4 10.7 16.1 1.7 20.6 11.1 106 7 102 165 9.4 0.3 9.6 8.8 10/08/2006 10:00:00 17 2.1 21.4 11.5 17.3 2.1 21.8 11.5 16.3 2.2 20.6 10.3 107 8 107 165 9.4 0.3 9.6 8.8 10/08/2006 10:10:00 17 2 22.9 11.8 17.3 2 23.7 12.2 16.1 2.1 23.3 11.1 105 8 104 165 9.4 0.3 9.6 8.8 10/08/2006 10:20:00 17.5 2.3 22.9 9.5 17.8 2.4 23.3 9.9 16.5 2.6 22.1 10.7 103 7 104 165 9.4 0.3 9.6 9 10/08/2006 10:30:00 17.3 2 21.8 10.7 17.6 2.1 22.1 11.1 16.2 2.1 21.8 11.1 100 7 93 165 9.4 0.2 9.6 9 10/08/2006 10:40:00 16 2 21 11.1 16.2 2 21.4 10.3 15 2 21 9.9 100 7 102 165 9.4 0.2 9.6 8.8 10/08/2006 10:50:00 14 2.2 18.7 8.8 14.2 2.2 19.1 8.8 13.4 2.2 18.7 8.4 97 10 83 165 9.4 0.3 9.6 8.8 10/08/2006 11:00:00 13.5 2.7 19.9 6.8 13.7 2.8 19.9 7.6 12.7 2.7 20.2 7.2 103 10 112 165 9.5 0.2 9.8 9 10/08/2006 11:10:00 13.7 2.6 20.6 8 13.9 2.6 21 8 13.1 2.6 20.2 6.8 102 11 98 165 9.7 0.1 9.8 9.3 10/08/2006 11:20:00 14.1 2.1 20.6 8.4 14.3 2.1 21 8.4 13.6 2.1 19.5 8 102 13 105 165 9.7 0.1 10.1 9.3 10/08/2006 11:30:00 11.1 2.1 18.3 7.2 11.2 2.2 19.5 7.2 10.6 2.1 18.7 6.5 106 11 107 165 9.6 0.1 10.3 9.3 10/08/2006 11:40:00 12 1.7 16.4 7.2 12.1 1.8 17.2 7.6 11.4 1.8 16.1 6.8 111 11 96 165 9.8 0 10.1 9.3 10/08/2006 11:50:00 12.9 1.8 17.2 8.4 13 1.8 17.2 6.8 12.1 1.9 17.2 6.8 116 9 117 165 9.9 0.1 10.3 9.6 10/08/2006 12:00:00 12.6 2.1 18.7 8.4 12.7 2.1 19.1 8.4 12.2 2 17.9 8 124 9 133 165 10 0.2 10.3 9.6 10/08/2006 12:10:00 13.5 1.9 18.7 9.1 13.6 2 19.5 8.8 13.2 2.1 19.1 8 130 9 122 165 10.1 0.1 10.6 9.6 10/08/2006 12:20:00 13.7 1.7 17.6 8.4 13.7 1.7 17.9 8 13.2 1.8 17.9 9.1 133 8 128 165 10.1 0 10.6 9.8 10/08/2006 12:30:00 11.6 1.8 16.1 6.8 11.6 1.9 15.6 6.5 11.2 1.9 16.4 6.1 139 9 133 165 10.3 0 10.9 9.8 10/08/2006 12:40:00 11.2 1.4 14.5 8 11.1 1.4 14.5 8 11 1.5 14.9 7.2 143 8 136 165 10.2 0 10.9 10.1 10/08/2006 12:50:00 9.7 1 13 6.8 9.6 1 12.6 6.8 9.7 1 14.5 6.8 143 7 143 165 10.1 0 10.6 9.8 10/08/2006 13:00:00 10.1 1.3 14.1 6.5 10 1.4 13.7 6.5 10 1.2 13.3 7.2 145 6 147 165 10 0 10.3 9.8 10/08/2006 13:10:00 9.7 1.7 13 5.7 9.6 1.8 13 5.7 9.5 1.7 13 6.1 148 3 155 165 9.9 0 10.3 9.6 10/08/2006 13:20:00 8.8 2.1 12.6 4.9 8.6 2.2 12.6 4.6 8.6 2.1 12.2 4.6 140 6 126 165 10 0 10.3 9.6 10/08/2006 13:30:00 9.6 1.3 12.2 6.1 9.4 1.3 12.6 6.1 9.4 1.4 11.8 5.3 140 9 142 165 10 0 10.6 9.8 10/08/2006 13:40:00 10.9 1 13.3 7.6 10.9 1.1 13.3 7.2 10.7 1 13.3 7.6 139 6 128 165 10.1 0 10.6 9.8 10/08/2006 13:50:00 9.2 1 11.5 6.8 9.1 1 11.8 6.8 9 1 12.2 6.5 138 5 143 165 10.1 0.1 10.6 9.6 10/08/2006 14:00:00 9.2 1 11.8 6.5 9.1 1 11.5 5.7 8.8 1 11.5 6.1 136 7 145 165 10.1 0.1 10.6 9.6 10/08/2006 14:10:00 8.6 1.1 11.8 5.3 8.5 1.2 11.8 4.9 8.4 1.2 11.1 5.3 135 7 140 165 10.1 0.2 10.6 9.6 10/08/2006 14:20:00 8.5 0.9 10.7 5.7 8.4 1 10.7 4.9 8.2 0.9 9.9 5.7 135 6 130 165 10.1 0.1 10.6 9.6 10/08/2006 14:30:00 8 1.1 11.1 4.9 8 1.2 11.1 4.9 7.6 1.1 9.9 4.9 134 7 130 165 10.3 0.1 10.6 9.6 10/08/2006 14:40:00 8.2 1 10.7 4.9 8.1 1.1 10.3 4.2 7.8 1 10.3 4.9 132 7 115 165 10.4 0 10.9 9.8 10/08/2006 14:50:00 8.2 0.8 10.3 5.3 8.1 0.9 10.3 5.3 7.7 0.9 9.9 5.3 133 6 139 165 10.4 0 10.9 9.8 10/08/2006 15:00:00 7.6 0.8 9.5 4.9 7.5 0.9 9.9 4.2 7.2 1 9.1 4.6 133 7 125 165 10.6 0.1 10.9 10.3 10/08/2006 15:10:00 8.1 0.8 9.9 6.1 8 0.8 10.3 5.3 7.6 1 9.9 4.6 135 6 136 165 10.6 0.1 10.9 10.1 10/08/2006 15:20:00 8.4 0.6 10.3 6.1 8.3 0.7 9.9 5.3 8 0.8 10.3 5.7 137 6 140 165 10.6 0.1 10.9 10.3 10/08/2006 15:30:00 8.5 0.8 10.7 5.3 8.3 0.8 10.3 5.3 7.8 1 9.9 4.6 134 7 146 165 10.5 0 10.9 10.1 10/08/2006 15:40:00 7.6 1.1 9.9 4.6 7.4 1.2 10.3 4.2 7 1 10.3 4.6 134 9 138 165 10.5 0 10.6 10.3 10/08/2006 15:50:00 8.1 0.9 10.3 4.9 8.1 0.9 10.3 4.9 7.9 1 9.9 4.2 128 7 132 165 10.3 0 10.6 10.3 10/08/2006 16:00:00 6.5 1 9.9 3.8 6.3 1 9.9 3.8 6.1 1.1 9.5 3.8 127 9 129 165 10.3 0 10.6 10.3 10/08/2006 16:10:00 5.2 1 7.2 2.6 5.1 1 7.6 2.3 5 1 8 2.3 126 10 121 165 10.3 0 10.6 10.3 10/08/2006 16:20:00 5.6 1 8.4 3 5.5 1.1 8.4 2.6 5.2 1 7.6 2.6 137 9 142 165 10.2 0 10.6 10.3 10/08/2006 16:30:00 7.1 1 9.5 4.6 6.8 0.9 9.1 4.6 6.7 1 9.1 4.2 139 8 133 165 10.1 0 10.6 9.8 10/08/2006 16:40:00 7.8 1.1 10.7 5.3 7.5 1.1 11.1 4.9 7.6 1 11.5 5.7 139 7 133 165 10 0 10.3 9.8 10/08/2006 16:50:00 7.4 0.7 10.3 5.7 7.2 0.8 9.9 4.9 7.1 0.8 9.5 4.9 139 7 141 165 10 0 10.3 9.6 10/08/2006 17:00:00 7.4 0.8 9.5 4.6 7.1 0.8 9.5 4.6 6.8 0.8 9.5 4.6 135 7 126 165 10 0 10.3 9.8 10/08/2006 17:10:00 8.4 0.8 9.9 5.3 8.2 0.8 10.3 5.7 8 0.9 9.9 5.3 135 5 135 165 10 0 10.3 9.6 10/08/2006 17:20:00 8.8 0.7 10.7 6.8 8.6 0.7 10.7 6.5 8.4 0.7 10.3 6.1 135 4 136 165 10 0 10.3 9.8 10/08/2006 17:30:00 9.9 1.5 13 6.5 9.8 1.6 13 6.1 9.6 1.6 13 6.1 139 5 144 165 10 0 10.3 9.6 10/08/2006 17:40:00 9.5 0.9 12.2 6.8 9.5 1 12.6 6.8 9.1 1 12.2 6.1 136 5 136 165 9.9 0 10.3 9.6 10/08/2006 17:50:00 8 0.8 9.5 5.3 7.9 0.9 9.5 5.3 7.4 1 9.5 4.9 135 5 137 165 9.9 0 10.3 9.6 10/08/2006 18:00:00 7.2 1 9.1 4.9 7.1 1 9.1 4.6 6.8 0.9 9.1 4.6 132 5 135 165 10 0 10.3 9.8 10/08/2006 18:10:00 6.3 1 8.4 4.2 6.2 1 8.4 4.2 6.2 1 8.4 4.2 133 8 135 165 10 0 10.3 9.8 10/08/2006 18:20:00 6.3 1.2 8.8 3.8 6.3 1.2 8.8 3.4 6.2 1.2 8.8 3.4 135 9 142 165 10 0 10.3 9.8 10/08/2006 18:30:00 9 1.4 11.5 4.9 8.8 1.5 11.5 4.9 8.7 1.4 11.5 5.3 138 8 133 165 10 0 10.3 9.8 10/08/2006 18:40:00 9 0.9 11.1 6.5 8.9 1 11.1 6.5 8.7 0.9 11.1 6.5 138 5 135 165 9.9 0 10.3 9.6 10/08/2006 18:50:00 7.4 1 9.9 5.3 7.3 1 9.9 4.6 7.4 1 9.9 4.9 135 7 130 165 9.8 0 10.1 9.6 10/08/2006 19:00:00 6.5 0.7 8 4.6 6.3 0.8 8 4.2 6.4 0.7 8 4.6 132 6 136 165 10.1 0.1 10.6 9.6 10/08/2006 19:10:00 6 1.2 8.4 2.6 5.8 1.1 8.4 3 5.9 1.1 8 3.4 131 6 130 165 10.2 0 10.9 9.8 10/08/2006 19:20:00 6.3 0.7 8.8 4.6 6.3 0.8 8.4 4.6 6.1 0.7 8.4 4.2 129 7 130 165 10.3 0 10.6 9.8 10/08/2006 19:30:00 8 1 10.3 5.7 7.9 1 10.3 5.3 7.8 1 10.3 5.3 128 9 128 165 10.4 0 10.6 10.3 10/08/2006 19:40:00 6.9 1.7 12.6 4.2 6.8 1.9 13 3.8 6.6 1.7 11.8 3 120 11 122 165 10.4 0.1 10.9 10.3 10/08/2006 19:50:00 9.7 1.2 12.6 6.5 9.8 1.2 12.6 6.8 9.4 1.2 13 6.5 113 7 112 165 10.6 0.2 10.9 9.8 10/08/2006 20:00:00 9.5 1.4 13 5.7 9.6 1.5 13.3 6.1 9.1 1.5 13.7 5.7 109 7 109 165 10.5 0.2 11.1 9.8 10/08/2006 20:10:00 9.4 1.1 12.6 6.5 9.4 1.2 13 6.1 9 1.3 12.6 5.3 116 7 109 165 10.8 0 11.4 10.9 10/08/2006 20:20:00 9.9 1.2 13.3 6.8 10 1.3 14.5 6.8 9.5 1.3 14.1 6.5 112 8 113 165 10.9 0 11.1 10.6 10/08/2006 20:30:00 11.6 1.3 14.9 7.2 11.8 1.3 15.3 7.6 11.1 1.5 14.9 6.8 109 6 110 165 11.1 0 11.4 10.9 10/08/2006 20:40:00 11.2 1.2 15.3 8 11.5 1.2 16.1 8.8 10.6 1.5 15.6 7.2 113 7 109 165 10.9 0 11.4 10.9 10/08/2006 20:50:00 10 1 13.3 7.2 10.2 1 13.7 7.2 9.6 1.2 12.6 6.5 113 8 122 165 10.8 0 11.1 10.9 10/08/2006 21:00:00 10.3 1.1 13 6.8 10.5 1.1 13 7.6 9.9 1.1 12.6 6.8 118 7 113 165 10.8 0 11.1 10.9 10/08/2006 21:10:00 10.7 1.5 14.1 6.5 10.9 1.5 14.1 6.1 10.5 1.3 13.7 6.5 117 8 116 165 10.8 0 11.1 10.9 10/08/2006 21:20:00 10.2 1.3 14.9 6.5 10.3 1.4 14.5 6.1 9.9 1.5 13.7 6.1 124 9 128 165 10.7 0 11.1 10.9 10/08/2006 21:30:00 10.4 1.5 14.9 7.2 10.4 1.5 15.3 7.2 10.1 1.5 15.3 6.1 131 9 127 165 10.7 0 10.9 10.6 10/08/2006 21:40:00 11.4 1.2 14.9 7.2 11.5 1.2 14.9 7.2 11 1.4 14.5 6.8 138 7 137 165 10.5 0 10.9 10.3 10/08/2006 21:50:00 10.7 1.3 13.7 8 10.7 1.4 13.3 7.2 10.5 1.6 14.1 7.2 140 6 141 165 10.3 0 10.6 10.3 10/08/2006 22:00:00 11 1.3 14.1 7.6 10.9 1.4 14.5 7.2 10.6 1.5 13.7 6.5 143 7 144 165 10.3 0 10.6 10.3 10/08/2006 22:10:00 11.8 0.9 14.5 9.5 11.7 0.9 14.1 9.5 11.6 0.9 13.7 9.1 147 4 151 165 10.4 0 10.9 10.3 10/08/2006 22:20:00 12.8 1 15.3 10.7 12.8 1 15.6 10.3 12.5 1 16.1 9.5 147 5 151 165 10.6 0.1 10.9 10.1 10/08/2006 22:30:00 13.5 1 17.2 11.1 13.5 1 17.6 11.1 13.4 1.1 16.8 10.3 147 5 143 165 10.7 0.2 11.1 10.1 10/08/2006 22:40:00 15.5 1.5 19.1 11.5 15.4 1.5 18.7 11.8 15.2 1.8 19.1 10.3 147 5 148 165 10.8 0.1 11.1 10.3 10/08/2006 22:50:00 16.1 1 18.3 13.7 16.1 1 18.7 13.3 15.9 1.1 18.7 13 148 4 151 165 10.8 0 11.1 10.6 10/08/2006 23:00:00 15.6 1 18.3 12.6 15.6 1 17.9 12.6 15.1 1.1 18.3 12.2 145 4 144 165 10.8 0 11.1 10.6 10/08/2006 23:10:00 16.1 0.9 18.3 13.3 16.1 0.9 18.3 13.3 15.7 1.1 19.1 13 145 4 150 165 10.8 0.1 11.1 10.3 10/08/2006 23:20:00 17.2 1 19.9 14.5 17.2 1 19.5 14.5 17 1.1 19.9 12.2 147 4 151 165 10.9 0 11.1 10.6 10/08/2006 23:30:00 17.4 0.8 19.5 15.3 17.3 0.7 19.1 15.3 17.2 0.8 18.7 14.5 149 3 156 165 10.9 0 11.1 10.6 10/08/2006 23:40:00 17.4 1.2 20.2 14.5 17.2 1.1 20.2 14.5 17.2 1.2 19.9 14.1 151 4 153 165 11 0 11.4 10.6 10/08/2006 23:50:00 16.8 1.3 20.6 13.7 16.7 1.2 20.2 13.7 16.7 1.3 19.9 13.3 151 3 151 165 11.1 0 11.4 10.9 10/09/2006 00:00:00 15.6 1 17.6 12.6 15.5 1 17.6 12.6 15.4 1 17.9 12.6 149 5 145 165 11.3 0.1 11.7 10.9 10/09/2006 00:10:00 16.9 1 19.5 14.1 16.7 1 19.5 14.1 16.4 1.1 19.1 13 149 4 154 165 11.1 0.1 11.4 10.9 10/09/2006 00:20:00 16.8 1.3 19.9 13 16.7 1.3 19.9 13 16.5 1.3 19.9 13 150 4 150 165 11.2 0.1 11.4 10.9 10/09/2006 00:30:00 16.7 1 19.1 13.7 16.6 1 19.1 13.7 16.4 1.1 19.1 13.3 149 4 150 165 11.3 0.1 11.4 10.9 10/09/2006 00:40:00 16.9 1.4 20.6 13 16.8 1.4 20.2 13 16.5 1.3 19.5 13 148 4 150 165 11.3 0 11.4 10.9 10/09/2006 00:50:00 16 1.1 19.9 13.3 16 1 19.9 13.7 15.7 1 19.1 13.3 148 4 149 165 11.3 0 11.4 11.1 10/09/2006 01:00:00 16.2 1 18.7 13.3 16.1 1 18.7 13 16 0.9 18.3 13 148 3 147 165 11.3 0 11.4 11.1 10/09/2006 01:10:00 16.3 1.1 18.7 13.3 16.3 1.1 19.1 13.3 16 1.1 19.9 13.3 146 5 146 165 11.3 0 11.7 11.1 10/09/2006 01:20:00 16.7 1.2 20.6 13.7 16.6 1.2 20.2 13.7 16.5 1.2 20.2 13.3 146 5 152 165 11.2 0 11.4 11.1 10/09/2006 01:30:00 17.3 1.2 21.4 14.5 17.2 1.1 21 14.9 17.3 1.1 20.2 13.7 149 5 152 165 11.1 0 11.4 11.1 10/09/2006 01:40:00 17.6 1.2 21 15.3 17.5 1.1 21 15.3 17.3 1.2 20.6 14.1 147 5 147 165 11.1 0 11.4 10.9 10/09/2006 01:50:00 17.9 1.3 21 14.9 17.8 1.3 21 14.9 17.5 1.5 21 14.5 148 5 145 165 11.2 0 11.4 10.9 10/09/2006 02:00:00 18.3 1.1 21.4 15.6 18.2 1.1 21.4 15.6 17.9 1.2 21.8 13.7 152 4 156 165 11.4 0 11.7 11.1 10/09/2006 02:10:00 19.9 1.3 23.3 16.8 19.7 1.3 22.9 16.4 19.8 1.3 23.7 16.4 153 4 150 165 11.6 0 11.9 11.4 10/09/2006 02:20:00 19.7 1.5 24.8 16.4 19.5 1.4 24 16.1 19.5 1.5 24.4 16.1 154 4 155 165 11.7 0 11.9 11.7 10/09/2006 02:30:00 19.6 1.4 23.7 16.1 19.4 1.3 23.3 16.1 19.5 1.2 22.1 16.1 151 5 152 165 11.7 0 11.9 11.7 10/09/2006 02:40:00 19.6 1.4 23.3 16.4 19.5 1.4 22.6 16.4 19.2 1.5 24 15.3 151 4 164 165 11.7 0 11.9 11.7 10/09/2006 02:50:00 18.7 1.3 22.1 15.6 18.5 1.2 22.1 15.6 18.6 1.3 22.6 15.3 152 4 152 165 11.5 0 11.7 11.4 10/09/2006 03:00:00 20.1 1.7 25.2 17.2 19.9 1.7 25.2 17.2 20 1.9 25.6 16.1 154 4 157 165 11.6 0 11.9 11.4 10/09/2006 03:10:00 22.4 1.3 26 19.1 22.2 1.2 26 18.7 22.2 1.2 26.3 19.1 155 3 157 165 11.8 0 11.9 11.7 10/09/2006 03:20:00 21.1 1.2 23.7 18.3 20.9 1.1 23.7 17.9 20.9 1.3 24 17.9 154 3 159 165 11.7 0 11.9 11.4 10/09/2006 03:30:00 21.7 1 24 18.7 21.5 1 24 18.3 21.6 1.1 24 18.3 154 3 154 165 11.7 0 11.9 11.4 10/09/2006 03:40:00 21.3 1.1 25.2 18.7 21.1 1.1 24.4 18.7 21.1 1.2 25.2 17.9 155 3 158 165 11.7 0 11.9 11.4 10/09/2006 03:50:00 20.6 1.2 25.2 18.3 20.5 1.1 24.8 17.9 20.5 1.2 25.6 17.6 154 4 159 165 11.7 0 11.9 11.4 10/09/2006 04:00:00 20.9 1.1 24 17.9 20.7 1.1 23.7 17.6 20.8 1.1 24 18.3 154 4 156 165 11.7 0 11.9 11.4 10/09/2006 04:10:00 20.3 1.1 23.3 16.8 20.1 1 22.9 16.8 20.1 1.1 22.6 16.4 152 3 153 165 11.6 0 11.9 11.4 10/09/2006 04:20:00 21.2 1 23.7 18.3 21 1 22.9 18.3 21 1.1 23.7 16.8 153 3 156 165 11.7 0 11.9 11.4 10/09/2006 04:30:00 21.5 1.3 25.6 18.7 21.3 1.3 25.2 18.3 21.3 1.4 25.6 16.8 153 3 156 165 11.7 0 11.9 11.7 10/09/2006 04:40:00 23.6 1.1 26.8 21 23.4 1.1 26.8 21 23.5 1.2 27.5 20.6 154 3 160 165 11.8 0 11.9 11.1 10/09/2006 04:50:00 23.5 1.1 25.6 20.2 23.3 1.1 25.2 20.2 23.5 1.1 26 20.2 156 3 144 165 11.9 0.1 12.2 11.1 10/09/2006 05:00:00 23.8 1.3 29.1 21 23.5 1.3 28.7 20.2 23.6 1.4 28.3 19.1 156 6 153 165 11.9 0.1 12.2 11.4 10/09/2006 05:10:00 24.3 1.1 27.5 21 24 1.1 27.1 20.6 24.3 1.2 27.1 20.6 156 3 157 165 12 0 12.2 11.9 10/09/2006 05:20:00 24.2 1.2 27.5 21.4 23.9 1.2 27.1 21.4 24 1.3 27.5 20.2 156 3 164 165 11.9 0 12.2 11.9 10/09/2006 05:30:00 22.9 1.5 27.1 19.1 22.7 1.5 26.8 19.1 23.1 1.6 28.7 19.9 157 5 164 165 12.1 0.2 12.5 11.9 10/09/2006 05:40:00 22.5 1.7 26.8 18.3 22.4 1.7 27.1 17.9 22.5 1.8 27.9 17.2 156 8 157 165 12 0.2 12.5 11.7 10/09/2006 05:50:00 22.2 1.3 26.3 17.9 22 1.3 25.6 17.6 22 1.5 27.5 17.6 156 4 162 165 12.1 0.1 12.5 11.9 10/09/2006 06:00:00 22.5 1.1 25.6 19.5 22.4 1.1 24.8 19.5 22.3 1.2 26 19.1 154 3 156 165 11.8 0 12.2 11.7 10/09/2006 06:10:00 23.3 1 26 21 23.1 1 25.6 20.6 23 1.2 26 19.1 154 3 153 165 11.8 0 11.9 11.7 10/09/2006 06:20:00 23.3 1 27.1 20.6 23.1 1 27.1 20.2 23.2 1.1 26.3 20.2 155 3 154 165 11.8 0 12.2 11.7 10/09/2006 06:30:00 23.3 1.3 26 19.9 23.1 1.2 25.6 19.9 23.2 1.4 26.8 19.5 154 3 157 165 11.8 0 11.9 11.7 10/09/2006 06:40:00 22.4 1.5 27.1 18.3 22.2 1.5 26.8 18.3 22.3 1.6 27.1 17.9 152 4 154 165 11.7 0 11.9 11.7 10/09/2006 06:50:00 20.3 1.6 24.4 17.2 20.1 1.6 24.4 17.6 19.9 1.7 24.8 16.4 151 5 151 165 11.7 0 11.9 11.4 10/09/2006 07:00:00 20 1.7 23.3 16.1 19.9 1.7 23.3 16.1 19.7 1.7 23.7 16.1 151 4 151 165 11.5 0 11.7 11.4 10/09/2006 07:10:00 20.5 1.5 23.7 16.8 20.4 1.4 23.7 17.2 20.3 1.7 23.7 16.1 152 4 154 165 11.6 0 11.7 11.4 10/09/2006 07:20:00 21.3 1.2 24.4 18.3 21.2 1.2 24.4 18.3 21.1 1.5 24.8 16.8 152 3 153 165 11.5 0 11.7 11.4 10/09/2006 07:30:00 21.5 1.2 25.2 17.2 21.3 1.1 25.2 17.9 21.3 1.2 25.2 16.4 155 4 158 165 11.4 0 11.7 11.1 10/09/2006 07:40:00 21.9 1.1 24.8 18.7 21.8 1.2 24.4 18.7 21.8 1.3 25.2 18.3 154 3 159 165 11.3 0 11.7 11.1 10/09/2006 07:50:00 23.9 1.5 28.3 20.6 23.7 1.4 27.5 20.2 23.9 1.7 29.1 19.1 155 10 152 165 11.3 0 11.7 11.1 10/09/2006 08:00:00 24.1 1.5 28.7 19.9 23.8 1.5 27.9 19.1 24.3 1.6 28.7 19.1 158 11 171 165 11.2 0 11.4 11.1 10/09/2006 08:10:00 24.1 1.6 27.9 19.9 23.8 1.6 27.9 18.7 24.1 1.6 28.7 20.2 157 9 156 165 11.1 0 11.4 10.9 10/09/2006 08:20:00 23.9 1.5 29.4 20.2 23.6 1.4 29.1 20.2 23.8 1.7 29.8 20.2 155 3 164 165 10.9 0 11.1 10.6 10/09/2006 08:30:00 23.1 1.3 26.8 19.9 22.8 1.2 26.3 19.9 23.2 1.4 26.8 19.5 156 5 147 165 10.7 0.1 11.1 10.3 10/09/2006 08:40:00 20.9 1.7 26.3 16.8 20.7 1.7 26 16.4 20.9 1.9 26.8 16.4 158 11 154 165 10.7 0.1 11.1 10.3 10/09/2006 08:50:00 22.3 1.5 27.1 18.7 22 1.4 26.3 18.3 22.7 1.6 26.3 16.8 161 8 166 165 10.5 0 10.9 10.3 10/09/2006 09:00:00 21.9 1.4 26 17.9 21.7 1.3 25.6 17.9 22.3 1.4 26 17.6 156 5 166 165 10.3 0 10.6 9.8 10/09/2006 09:10:00 19.7 1.2 23.3 16.4 19.6 1.2 23.3 16.1 19.8 1.4 23.7 15.6 157 8 163 165 10.2 0.1 10.6 9.6 10/09/2006 09:20:00 20.4 1.7 24.8 14.9 20.2 1.7 24.4 14.5 20.7 2 25.2 14.1 157 5 160 165 10.2 0.1 10.6 9.6 10/09/2006 09:30:00 20.2 1.3 24 16.4 20 1.2 23.3 16.4 20.4 1.3 24.4 16.8 162 17 159 165 10.2 0.1 10.6 9.6 10/09/2006 09:40:00 21.1 1.4 25.6 17.2 20.9 1.3 24.8 16.8 21 1.5 24 16.4 163 12 164 165 10.1 0.2 10.6 9.6 10/09/2006 09:50:00 21 1.4 24.8 17.2 20.8 1.3 24.4 16.8 21 1.4 24.4 17.6 163 12 164 165 10.2 0 10.6 10.1 10/09/2006 10:00:00 21.6 1.9 27.9 16.4 21.3 1.9 27.5 16.4 21.5 1.8 28.3 16.8 159 19 164 165 10.2 0 10.6 10.1 10/09/2006 10:10:00 22.1 1.7 26 16.8 21.9 1.7 26 17.2 22.4 1.7 26 16.8 162 23 158 165 10.3 0.1 10.6 10.1 10/09/2006 10:20:00 20.7 1.1 25.2 16.8 20.6 1.1 24.8 16.8 21.1 1.2 25.6 16.4 159 13 152 165 10.1 0 10.6 9.8 10/09/2006 10:30:00 20.6 2.1 26 14.9 20.4 2 25.6 14.9 20.7 2.3 25.2 14.5 162 15 164 165 10.1 0 10.3 9.8 10/09/2006 10:40:00 19.1 1.1 22.6 16.4 18.9 1.1 22.6 16.8 19 1.4 23.3 15.3 167 19 170 165 10 0 10.3 9.8 10/09/2006 10:50:00 19.3 1.4 22.6 15.3 19.1 1.4 22.1 15.3 19.4 1.5 23.3 14.1 162 6 161 165 10.1 0 10.3 9.8 10/09/2006 11:00:00 19.9 1.8 23.7 15.3 19.7 1.7 23.7 15.6 20.1 1.9 25.2 16.1 159 9 166 165 10 0 10.3 9.8 10/09/2006 11:10:00 20.2 1.4 23.7 15.6 20 1.4 23.3 15.3 20.3 1.5 24 15.6 158 5 163 165 10 0 10.3 9.6 10/09/2006 11:20:00 20.2 1.2 23.3 17.2 20 1.2 22.9 16.4 20.7 1.2 23.3 17.6 157 5 159 165 9.8 0 10.1 9.6 10/09/2006 11:30:00 21.5 1.1 24.4 18.7 21.2 1.1 24 17.6 21.9 1.3 25.2 17.6 156 4 155 165 9.8 0 10.1 9.6 10/09/2006 11:40:00 20.7 1.5 24 16.8 20.5 1.3 24 16.4 20.9 1.6 24.4 16.1 159 5 161 165 9.8 0 10.3 9.6 10/09/2006 11:50:00 19.9 1.5 23.7 15.6 19.7 1.5 23.3 15.3 20 1.7 23.7 15.6 162 8 164 165 10 0 10.3 9.6 10/09/2006 12:00:00 19 1.3 22.1 15.3 18.9 1.2 21.8 15.3 19.1 1.4 22.9 15.3 162 8 172 165 9.9 0 10.3 9.3 10/09/2006 12:10:00 17.5 1.6 21.4 12.6 17.4 1.5 20.6 13 17.5 1.8 21.4 13 162 9 164 165 9.9 0 10.3 9.6 10/09/2006 12:20:00 19.7 1 22.6 17.2 19.4 1 22.1 17.2 19.9 1.2 23.3 17.2 164 15 164 165 10 0 10.3 9.6 10/09/2006 12:30:00 19.5 1.6 24.4 15.3 19.2 1.5 23.7 15.6 19.6 1.7 24.4 15.6 168 15 173 165 10 0 10.3 9.6 10/09/2006 12:40:00 18 1.3 21.4 14.9 17.7 1.3 21 14.9 18.2 1.4 21.8 14.1 164 13 161 165 10 0 10.6 9.3 10/09/2006 12:50:00 18.2 1.2 22.1 15.3 18 1.2 22.1 14.9 18.4 1.3 22.6 15.3 166 10 168 165 9.9 0 10.3 9.6 10/09/2006 13:00:00 19.1 1.3 22.6 15.6 18.9 1.2 22.6 15.6 19.2 1.5 23.3 15.3 164 10 230 165 10 0 10.3 9.3 10/09/2006 13:10:00 18.1 1 21 14.9 17.8 0.9 20.6 15.3 18.4 1.1 21.4 15.6 164 9 169 165 9.9 0 10.1 9.6 10/09/2006 13:20:00 19 1.5 22.6 15.6 18.8 1.5 22.1 15.3 19.1 1.7 23.3 15.3 165 17 170 165 9.9 0 10.1 9.3 10/09/2006 13:30:00 20.8 1.3 24.8 16.8 20.5 1.3 24.4 16.8 20.9 1.5 25.6 16.8 166 9 177 165 10 0 10.3 9.3 10/09/2006 13:40:00 23.6 2 28.3 17.9 23.2 1.9 27.9 17.6 23.7 2 29.4 19.1 169 13 164 165 10 0 10.3 9.3 10/09/2006 13:50:00 22.6 1.5 26 17.6 22.2 1.5 25.2 17.9 22.6 1.6 26 17.2 168 15 180 165 10 0 10.3 9.3 10/09/2006 14:00:00 21.7 1.7 25.2 16.8 21.3 1.6 25.2 16.8 21.9 1.7 25.2 16.4 168 15 163 165 10 0 10.3 9.3 10/09/2006 14:10:00 22.2 1.6 26.3 16.8 21.8 1.5 25.6 16.4 22.4 1.7 26.3 17.9 169 17 165 165 10 0 10.3 9.3 10/09/2006 14:20:00 21.3 1.5 25.6 17.6 21 1.5 24.8 17.2 21.6 1.5 26 18.3 166 15 161 165 10 0 10.3 9.6 10/09/2006 14:30:00 22.8 2 29.4 18.7 22.5 2 28.7 17.9 23.1 2 29.4 18.7 169 14 181 165 10 0 10.3 9.6 10/09/2006 14:40:00 22.7 1.4 26.8 19.1 22.3 1.4 26 18.7 22.9 1.5 27.9 19.5 168 12 168 165 10.1 0 10.3 9.8 10/09/2006 14:50:00 21.6 1.2 24.4 17.9 21.2 1.2 24 17.2 21.9 1.3 24.8 18.3 167 15 164 165 10.1 0 10.3 9.8 10/09/2006 15:00:00 20.7 1.6 24.4 16.8 20.3 1.6 24 17.2 20.9 1.7 24.8 17.2 167 12 165 165 10.1 0 10.3 9.8 10/09/2006 15:10:00 20.9 1.2 24 17.9 20.5 1.1 23.3 17.2 21 1.3 24 16.8 168 17 165 165 10 0 10.3 9.8 10/09/2006 15:20:00 20.3 1.2 22.9 17.2 19.9 1.2 22.9 16.8 20.3 1.2 22.9 16.8 168 14 164 165 10 0 10.3 9.8 10/09/2006 15:30:00 19.8 1.4 23.7 16.1 19.3 1.4 23.3 15.6 19.9 1.4 24.4 16.8 167 22 172 165 9.9 0 10.3 9.6 10/09/2006 15:40:00 19.8 1.2 22.6 16.4 19.4 1.1 22.1 16.1 19.7 1.3 23.3 16.4 170 9 175 165 10 0 10.3 9.8 10/09/2006 15:50:00 18.7 1.7 22.1 15.3 18.4 1.7 21.8 15.3 18.8 1.8 22.6 14.5 168 13 165 165 9.9 0 10.3 9.6 10/09/2006 16:00:00 16 0.9 17.9 12.6 15.7 0.9 17.6 12.6 16 1 17.9 12.2 166 17 164 165 9.6 0.1 10.1 9.3 10/09/2006 16:10:00 14.6 0.8 16.8 12.6 14.3 0.8 16.4 11.8 14.8 0.9 17.6 12.2 167 14 166 165 9.5 0.1 9.6 9.3 10/09/2006 16:20:00 14.5 1 17.2 12.2 14.4 1 17.2 11.8 14.4 1 17.2 11.5 162 6 167 165 9.6 0.1 9.8 9 10/09/2006 16:30:00 14.9 1 17.2 11.5 14.7 1 16.8 11.5 15 1 17.2 11.8 154 4 159 165 9.3 0.1 9.8 9 10/09/2006 16:40:00 17.2 1 19.5 14.1 17 1 19.5 13.7 17.2 1.1 19.9 14.5 156 4 154 165 9.2 0 9.3 8.8 10/09/2006 16:50:00 16.8 1 19.1 14.5 16.5 1 18.7 14.1 17 1 19.5 13.7 158 9 161 165 9.2 0.1 9.6 8.8 10/09/2006 17:00:00 16 1 17.9 13.7 15.7 1 18.3 13.7 16.2 1 18.3 13.3 158 4 163 165 9.2 0.1 9.6 9 10/09/2006 17:10:00 16.4 1 19.1 13 16.1 1 19.1 13 16.7 1 19.1 13 158 6 157 165 9.2 0.1 9.6 9 10/09/2006 17:20:00 16.5 1.3 19.5 11.8 16.3 1.2 19.1 12.2 16.6 1.3 19.5 13.7 159 9 162 165 9.2 0.1 9.6 8.8 10/09/2006 17:30:00 16.9 0.9 19.5 14.1 16.7 0.9 19.1 14.1 17.2 1 19.5 13 157 9 154 165 9.2 0.1 9.6 9 10/09/2006 17:40:00 16.7 1 19.5 14.1 16.5 1 18.7 14.1 17 1 19.5 13.3 156 4 154 165 9.2 0 9.8 8.8 10/09/2006 17:50:00 16.6 1 19.5 14.1 16.4 1 19.5 13.7 16.6 1.1 19.5 13 154 5 154 165 9.2 0.1 9.6 9 10/09/2006 18:00:00 18.3 0.9 20.6 15.6 18.1 0.9 20.6 15.6 18.5 1 21 15.3 154 3 160 165 9.1 0.1 9.3 8.8 10/09/2006 18:10:00 17.9 0.8 20.2 15.6 17.6 0.8 19.9 14.9 18 0.8 20.6 15.3 155 3 154 165 9.1 0.1 9.3 8.8 10/09/2006 18:20:00 16.5 0.8 18.3 13.3 16.3 0.8 17.9 13.3 16.8 0.9 18.7 13 157 12 156 165 9 0.1 9.3 8.8 10/09/2006 18:30:00 16.2 0.8 18.7 13.7 16 0.8 18.3 13.3 16.3 0.8 18.7 13.7 157 9 156 165 9 0.1 9.3 8.8 10/09/2006 18:40:00 16.6 0.8 18.7 14.9 16.4 0.8 19.1 14.5 17 0.9 19.5 14.9 156 4 158 165 8.9 0.2 9.3 8.5 10/09/2006 18:50:00 16 1.1 18.7 13 15.7 1 18.3 13 16.2 1.1 19.1 13 158 8 158 165 9 0.1 9.3 8.5 10/09/2006 19:00:00 16.7 1.3 19.9 12.6 16.4 1.3 19.5 11.8 16.8 1.5 19.9 10.3 159 12 163 165 9 0.1 9.3 8.8 10/09/2006 19:10:00 15.7 1.2 18.7 11.8 15.5 1.1 18.3 12.2 15.7 1.3 19.5 11.8 160 14 164 165 9.1 0.1 9.3 8.8 10/09/2006 19:20:00 17.4 0.8 19.5 15.3 17.1 0.7 19.5 14.9 17.6 0.9 19.5 14.9 157 4 160 165 9 0.1 9.3 8.8 10/09/2006 19:30:00 17.4 1 19.9 13.7 17.1 0.9 19.5 14.1 17.6 1 19.5 13.7 157 8 159 165 9 0.2 9.3 8.5 10/09/2006 19:40:00 17.2 1 19.9 14.5 16.9 1 19.5 14.5 17.6 1 20.2 14.1 157 5 158 165 9 0.2 9.3 8.5 10/09/2006 19:50:00 16.2 1 19.5 12.6 16 1 19.1 13 16.5 1.2 19.9 13 158 10 151 165 9 0.2 9.3 8.5 10/09/2006 20:00:00 18.1 2.6 23.3 13.7 17.7 2.5 22.9 13.3 18.4 2.7 24 13 166 6 170 165 8.9 0.2 9.3 8.3 10/09/2006 20:10:00 20.4 1.4 23.7 16.4 19.9 1.3 22.9 16.1 20.6 1.5 24.8 16.8 170 14 167 165 8.4 0 8.8 8 10/09/2006 20:20:00 19.3 1.5 23.3 15.3 19 1.5 23.3 14.9 19.4 1.7 24 15.6 166 17 166 165 8.1 0 8.3 7.8 10/09/2006 20:30:00 18.4 1.3 21.8 14.5 18.1 1.2 21.4 14.5 18.5 1.3 21.4 15.3 165 11 165 165 8.1 0 8.5 8 10/09/2006 20:40:00 18.3 1.7 22.9 14.5 17.9 1.6 22.1 14.5 18.3 1.7 22.1 14.5 166 8 167 165 8.1 0 8.3 7.8 10/09/2006 20:50:00 18.6 1.7 22.9 14.1 18.2 1.6 22.6 14.1 18.6 1.8 23.7 13.7 168 13 168 165 8 0 8.3 7.8 10/09/2006 21:00:00 17.9 1.2 21 15.3 17.5 1.1 20.2 14.9 18 1.3 21.4 14.1 168 6 178 165 8 0 8.5 7.8 10/09/2006 21:10:00 16.4 1.3 20.2 13.3 16 1.2 19.1 13.3 16.6 1.3 20.2 13.3 168 17 165 165 8.1 0 8.3 7.8 10/09/2006 21:20:00 16.8 1.2 20.2 13 16.5 1.2 19.5 13.7 17.1 1.3 20.6 13.3 171 6 174 165 8.1 0 8.3 7.8 10/09/2006 21:30:00 15 1.1 17.9 11.5 14.7 1.1 17.2 11.5 15.2 1.3 18.3 11.5 170 6 167 165 8 0 8.3 7.8 10/09/2006 21:40:00 13.6 0.9 16.1 11.1 13.2 0.8 15.3 11.1 13.8 1 16.4 11.1 170 5 166 165 8 0 8.3 7.8 10/09/2006 21:50:00 14.5 1 17.2 11.5 14.1 1 16.4 11.5 14.6 1.1 17.2 11.5 171 6 168 165 8 0 8.3 7.8 10/09/2006 22:00:00 14 1.2 17.2 11.1 13.5 1.1 16.4 11.1 14.3 1.1 17.9 11.8 171 5 177 165 8 0 8.5 7.5 10/09/2006 22:10:00 11.7 1 13.7 9.1 11.3 1 13.3 8.8 11.9 1 14.1 8.8 171 16 170 165 8 0 8.3 7.8 10/09/2006 22:20:00 9.6 0.6 11.1 8 9.2 0.6 10.7 7.2 9.7 0.6 11.5 8 171 6 174 165 8 0 8.3 7.5 10/09/2006 22:30:00 10 0.6 11.5 8 9.6 0.6 11.1 7.6 10.1 0.7 11.8 8.4 172 13 165 165 8 0 8.3 7.8 10/09/2006 22:40:00 9.9 0.7 11.5 8.4 9.4 0.8 11.1 7.6 9.9 0.8 11.8 8 172 4 177 165 8.1 0 8.3 7.8 10/09/2006 22:50:00 9.2 0.4 10.3 8 8.7 0.4 9.9 7.6 9.3 0.4 10.3 8 172 5 173 165 8.1 0 8.3 7.8 10/09/2006 23:00:00 9.6 0.9 11.8 8 9.2 0.9 11.8 7.6 9.5 0.8 12.2 7.6 169 16 184 165 8.2 0 8.5 8 10/09/2006 23:10:00 9.4 0.9 11.8 7.2 9 0.9 11.5 6.8 9.5 0.8 11.5 7.6 168 7 176 165 8.3 0 8.5 8 10/09/2006 23:20:00 9.3 0.6 11.5 7.6 8.9 0.6 11.1 7.2 9.4 0.5 11.5 8 161 4 160 165 8.3 0 8.5 8 10/09/2006 23:30:00 8.8 0.5 10.3 7.6 8.5 0.5 9.9 7.2 9 0.5 10.7 6.8 159 7 164 165 8.3 0 8.5 8 10/09/2006 23:40:00 8.2 0.9 10.7 5.3 7.9 0.9 10.7 4.9 8.4 1 11.1 5.7 154 10 144 165 8.4 0 8.5 8.3 10/09/2006 23:50:00 8.2 1 10.3 5.3 7.8 1 9.9 5.3 8.4 1 11.1 6.5 159 6 154 165 8.4 0 8.5 8.3 10/10/2006 00:00:00 10.6 1.7 13.7 7.6 10.3 1.7 13.3 7.2 10.8 1.6 14.5 7.6 162 7 165 165 8.3 0 8.8 8 10/10/2006 00:10:00 12.4 0.7 14.5 10.3 12 0.7 14.1 9.5 12.6 0.8 14.9 10.3 168 14 170 165 8 0 8.3 7.5 10/10/2006 00:20:00 15.1 1.2 17.9 11.5 14.6 1.1 17.6 11.5 15.3 1.4 18.3 11.1 170 6 174 165 7.8 0.1 8 7.3 10/10/2006 00:30:00 13.6 0.8 15.3 11.1 13.1 0.8 14.5 11.1 13.8 0.9 15.6 11.1 171 8 174 165 7.7 0.1 8 7.3 10/10/2006 00:40:00 12.2 0.7 13.7 10.3 11.8 0.6 13.7 9.9 12.5 0.8 14.9 10.7 170 9 166 165 7.7 0 7.8 7.3 10/10/2006 00:50:00 11.9 0.9 13.7 9.5 11.5 0.8 13.3 9.5 12.1 0.9 14.1 9.5 171 5 172 165 7.6 0 8 7.3 10/10/2006 01:00:00 11.2 0.8 12.6 9.1 10.8 0.8 12.6 8.8 11.3 0.9 13.3 8.8 169 9 176 165 7.6 0 7.8 7.3 10/10/2006 01:10:00 10.5 0.6 11.8 8.8 10.2 0.6 11.5 8.8 10.7 0.7 13 8.8 166 14 165 165 7.6 0 7.8 7.3 10/10/2006 01:20:00 10.3 0.5 11.8 8.8 9.9 0.5 11.5 8.4 10.5 0.6 11.8 8.8 169 10 173 165 7.5 0.1 7.8 7.3 10/10/2006 01:30:00 11.3 0.6 12.6 9.1 10.9 0.6 12.2 9.1 11.6 0.7 13.3 9.5 170 11 170 165 7.4 0.1 7.8 7 10/10/2006 01:40:00 10.7 0.8 12.6 8.4 10.3 0.8 12.2 8 10.9 1 13 8 173 5 169 165 7.4 0.1 7.5 7 10/10/2006 01:50:00 9.7 1.1 12.6 7.2 9.3 1.1 12.2 7.2 9.8 1.1 13.3 7.6 176 6 176 165 7.4 0 7.8 7 10/10/2006 02:00:00 9.6 1.2 12.6 7.2 9.2 1.1 12.2 6.8 9.9 1.2 13 7.2 177 6 180 165 7.4 0.1 7.8 7 10/10/2006 02:10:00 8.6 0.8 11.1 6.5 8.4 0.9 11.1 6.5 8.7 0.9 12.6 6.1 185 8 194 165 7.3 0.1 7.5 6.7 10/10/2006 02:20:00 8.3 1.5 13 5.7 8.2 1.5 12.2 5.3 8.4 1.4 12.2 5.3 190 9 193 165 7.2 0 7.5 6.7 10/10/2006 02:30:00 7.9 1 9.9 5.7 7.8 1 10.3 5.7 8.1 0.9 11.1 6.5 196 7 194 165 7.1 0 7.3 6.5 10/10/2006 02:40:00 7.6 0.9 9.9 4.9 7.6 0.9 9.9 4.6 7.5 1 9.9 4.9 196 7 207 165 7.1 0 7.3 6.5 10/10/2006 02:50:00 6.6 0.8 8.8 4.6 6.6 0.8 9.1 4.2 6.8 0.8 9.1 4.6 197 6 193 165 7 0 7.3 6.2 10/10/2006 03:00:00 7 0.9 9.5 4.2 6.9 0.9 9.1 4.6 7.1 0.9 9.1 4.6 195 7 191 165 6.9 0.1 7.3 6.2 10/10/2006 03:10:00 8.5 0.9 11.1 6.5 8.4 0.9 10.7 6.1 8.8 0.9 11.1 6.5 189 6 190 165 6.7 0 7 6.2 10/10/2006 03:20:00 8.9 0.8 11.1 7.2 8.8 0.8 10.7 6.8 9.1 1 11.5 6.8 187 4 192 165 6.7 0 7 6.2 10/10/2006 03:30:00 8.9 0.6 10.3 6.8 8.9 0.6 10.3 6.8 9.1 0.7 10.7 7.2 191 4 187 165 6.7 0 7 6.7 10/10/2006 03:40:00 7.2 1 9.1 5.3 7 1.1 9.5 4.9 7.5 1.1 9.5 5.3 180 10 192 165 6.7 0 7 6.5 10/10/2006 03:50:00 6.4 0.7 8 4.9 6.2 0.6 8 4.9 6.6 0.6 8.4 5.3 177 6 183 165 6.6 0 6.7 6.2 10/10/2006 04:00:00 6.5 0.7 8.4 4.9 6.4 0.7 8.4 4.6 6.7 0.8 8.8 4.9 179 8 180 165 6.6 0 7 6.2 10/10/2006 04:10:00 7 1 9.1 4.6 6.9 1 9.1 4.6 7.1 1.1 9.5 4.9 183 7 187 165 6.6 0 6.7 6.2 10/10/2006 04:20:00 7.5 0.8 9.5 5.3 7.1 0.8 9.1 4.9 7.5 0.8 9.9 5.7 173 10 168 165 6.7 0 7 6.2 10/10/2006 04:30:00 7.5 0.7 8.8 5.7 7.1 0.6 8.4 5.7 7.6 0.7 9.1 5.3 171 6 173 165 6.7 0 7 6.5 10/10/2006 04:40:00 7.4 0.6 9.1 5.7 7 0.6 8.4 5.3 7.7 0.7 9.5 6.1 172 11 181 165 6.7 0 7 6.2 10/10/2006 04:50:00 8.9 0.8 10.3 6.5 8.6 0.8 9.9 6.1 9.2 0.8 10.7 6.5 170 5 171 165 6.7 0 7 6.2 10/10/2006 05:00:00 9.5 0.8 11.1 7.2 9.2 0.8 10.7 6.5 9.7 0.8 11.8 7.6 170 5 177 165 6.6 0 6.7 6.2 10/10/2006 05:10:00 7.9 0.9 9.9 5.7 7.7 0.8 9.9 5.7 8.1 1 10.3 5.7 180 11 178 165 6.4 0 6.7 6.2 10/10/2006 05:20:00 7.2 1 10.3 5.7 7.1 0.9 9.9 5.7 7.7 1 11.1 5.7 182 8 165 165 6.4 0 6.7 6.2 10/10/2006 05:30:00 9.5 1.2 11.8 6.5 9.2 1.2 11.5 6.1 9.6 1.2 12.6 7.2 175 6 182 165 6.4 0.1 6.7 6 10/10/2006 05:40:00 10.1 0.8 11.8 8.4 9.8 0.7 11.5 8 10.2 0.8 12.2 8.4 175 6 178 165 6.2 0 6.2 6 10/10/2006 05:50:00 10.3 0.8 12.2 8 9.9 0.8 11.5 7.6 10.4 0.8 12.6 8.4 174 5 169 165 6.1 0 6.2 5.7 10/10/2006 06:00:00 9.8 0.7 11.5 7.2 9.3 0.7 11.1 7.2 10 0.8 11.8 8 174 6 176 165 5.9 0.1 6.2 5.5 10/10/2006 06:10:00 9.8 0.7 11.5 7.6 9.5 0.7 11.1 7.6 10 0.8 11.8 8 179 5 180 165 5.7 0 6 5.5 10/10/2006 06:20:00 10 1.5 14.1 5.7 9.7 1.5 13.7 5.3 10.2 1.5 13.7 5.3 181 9 181 165 5.7 0 6 5.5 10/10/2006 06:30:00 10.5 1.2 13.7 7.6 10.5 1.2 13.7 8 10.6 1.3 13.7 6.5 192 9 192 165 5.4 0 5.7 5.2 10/10/2006 06:40:00 8.6 1.2 11.8 5.7 8.6 1.2 11.5 5.7 8.8 1.2 11.8 5.7 198 8 188 165 5.2 0 5.5 5 10/10/2006 06:50:00 8.3 1.3 11.5 5.7 8.2 1.3 11.1 5.7 8.4 1.3 12.2 4.9 197 9 202 165 5.2 0 5.5 5 10/10/2006 07:00:00 6.3 1.5 9.5 3.4 6.3 1.5 9.5 3.4 6.6 1.4 10.3 4.2 194 9 187 165 5.2 0 5.7 5 10/10/2006 07:10:00 5.8 1 8.4 3.4 5.7 1 8.4 3 5.9 1 8 3.4 190 11 205 165 5.1 0 5.5 5 10/10/2006 07:20:00 5.9 1.2 8.8 3.4 5.8 1.1 8.8 3.4 5.9 1.1 8.4 3.4 200 10 208 165 5.1 0 5.2 5 10/10/2006 07:30:00 6.6 1.3 9.5 2.6 6.6 1.4 9.9 3 6.4 1.3 9.9 3.8 208 10 210 165 4.9 0 5.2 4.8 10/10/2006 07:40:00 6.8 1 9.1 4.2 6.9 1 9.1 3.8 6.7 1 9.5 4.2 209 9 215 165 5 0 5.2 4.8 10/10/2006 07:50:00 6.9 0.6 8.4 4.9 6.7 0.6 8 4.9 7 0.7 8.8 5.3 184 10 186 165 5.1 0.1 5.5 5 10/10/2006 08:00:00 6.2 0.6 8 4.6 6 0.6 7.6 4.2 6.5 0.7 8.4 4.9 179 9 183 165 5.5 0 5.7 5.2 10/10/2006 08:10:00 6.1 1.1 8.4 3.4 6 1.1 8.4 3.4 6.3 1 8.4 3.4 192 11 194 165 5.6 0 5.7 5.5 10/10/2006 08:20:00 4.7 1.2 9.5 1.9 4.6 1.2 9.1 1.5 4.7 1 9.1 2.3 193 16 194 165 5.7 0.1 6 5 10/10/2006 08:30:00 4.8 1 7.2 2.3 4.7 1 7.2 2.3 5 1 7.6 2.3 190 13 195 165 5.7 0.1 6 5.2 10/10/2006 08:40:00 5.4 1.2 8.4 3 5.4 1.1 8.8 2.6 5.5 1 8.8 3 198 11 197 165 5.9 0.1 6.2 5.2 10/10/2006 08:50:00 4.9 1.4 8 1.1 5 1.4 7.6 1.5 5.1 1.4 8.8 1.5 218 24 203 165 6 0 6.2 5.7 10/10/2006 09:00:00 5.9 1.3 9.1 2.6 5.8 1.3 9.5 3 5.7 1.1 9.5 3.4 201 13 213 165 6.2 0.1 6.7 6 10/10/2006 09:10:00 7.1 1 9.9 4.6 7 1 9.5 4.2 7.2 1 9.9 4.6 186 9 174 165 6.4 0.2 6.7 5.7 10/10/2006 09:20:00 6.7 1 9.1 3.8 6.6 1 9.1 3.8 7 0.9 9.1 4.6 184 10 196 165 6.6 0.2 7 6 10/10/2006 09:30:00 7.1 0.8 9.1 4.6 7 0.8 9.9 4.2 7.2 0.8 9.1 4.6 189 11 185 165 6.7 0 7 6.2 10/10/2006 09:40:00 7.5 1 10.3 4.9 7.5 1 10.7 4.6 7.6 1 9.9 5.3 191 8 198 165 6.9 0.1 7.3 6.2 10/10/2006 09:50:00 7.5 1 10.3 5.3 7.4 1 10.7 4.9 7.8 1 9.9 5.3 190 9 201 165 6.9 0 7.3 6.7 10/10/2006 10:00:00 7 1 9.5 4.6 7 1 9.9 4.6 7.2 1.1 10.3 4.9 187 10 198 165 7.3 0.2 7.8 7 10/10/2006 10:10:00 8.8 1 11.8 6.1 8.7 1 11.5 5.7 9 1 11.8 6.1 185 10 190 165 7.4 0 7.8 7.3 10/10/2006 10:20:00 9 1.2 12.6 6.5 8.9 1.2 11.8 6.1 9.3 1.2 13 6.8 184 9 179 165 7.4 0 7.8 7.3 10/10/2006 10:30:00 10.3 1.3 13 6.8 10.1 1.2 13.3 7.2 10.5 1.3 13.7 7.6 182 10 182 165 7.5 0 7.8 7.3 10/10/2006 10:40:00 10.6 1.2 13.3 6.8 10.4 1.2 13 6.1 10.9 1.2 13.7 7.6 184 7 179 165 7.6 0 7.8 7.3 10/10/2006 10:50:00 10.8 1.3 14.9 6.8 10.6 1.3 14.9 6.8 11 1.5 15.6 7.2 184 9 185 165 7.8 0 8 7.5 10/10/2006 11:00:00 9.5 1.5 13.7 6.8 9.4 1.5 13 6.5 9.7 1.7 14.5 6.1 186 9 191 165 8 0.1 8.5 7.8 10/10/2006 11:10:00 8.6 1.1 11.8 6.1 8.5 1.1 11.8 6.1 9 1.2 13 6.1 181 10 181 165 8.4 0.1 8.8 8.3 10/10/2006 11:20:00 11.6 1.4 14.9 8.4 11.4 1.3 14.5 8 12 1.4 15.6 8.8 185 14 187 165 8.1 0 8.5 7.8 10/10/2006 11:30:00 10.8 1.3 14.9 7.2 10.6 1.3 14.1 6.8 11.1 1.3 14.5 8 182 8 181 165 8 0 8.3 7.5 10/10/2006 11:40:00 9.8 1.3 13 6.1 9.6 1.3 13 5.7 10 1.3 13.3 5.7 182 9 185 165 8.1 0 8.5 8 10/10/2006 11:50:00 10.2 1.4 14.1 6.5 10.1 1.3 13.3 6.5 10.4 1.4 14.1 6.8 182 10 179 165 8.5 0 8.8 8.3 10/10/2006 12:00:00 11.4 1.5 14.1 7.6 11.3 1.4 13.7 6.8 11.6 1.6 14.9 7.6 188 10 184 165 8.6 0.1 9 8.3 10/10/2006 12:10:00 11.1 1.4 13.7 7.2 11 1.3 13.7 7.2 11.2 1.3 14.1 7.2 187 9 186 165 8.6 0.1 8.8 8.5 10/10/2006 12:20:00 10.9 1.4 14.9 6.1 10.8 1.5 14.9 5.7 11.4 1.3 15.3 6.8 184 10 196 165 8.7 0 9 8.5 10/10/2006 12:30:00 10.6 1.7 14.9 6.5 10.4 1.7 14.9 6.1 10.8 1.9 15.3 6.8 180 10 186 165 9 0.1 9.3 8.5 10/10/2006 12:40:00 11.3 1.3 14.9 8.4 11.2 1.2 14.5 8 11.6 1.3 16.1 8.4 186 8 193 165 8.3 0.2 8.8 7.8 10/10/2006 12:50:00 10.5 1.2 13.3 6.8 10.4 1.2 13.3 6.1 10.8 1.1 13.7 8 186 9 183 165 7.8 0 8.3 7.5 10/10/2006 13:00:00 9.7 1.2 13 6.8 9.5 1.1 12.2 6.8 10 1.2 13 7.2 181 8 183 165 7.6 0.2 8 7.3 10/10/2006 13:10:00 11.1 1.5 14.9 8 10.8 1.5 14.5 8 11.6 1.5 16.4 7.2 178 8 177 165 8.2 0.3 8.5 7.5 10/10/2006 13:20:00 10.3 1.2 13.7 7.2 10.3 1.2 13.3 7.2 10.5 1.3 14.1 6.5 188 9 196 165 7.6 0 7.8 7.5 10/10/2006 13:30:00 10.9 1.1 13.3 7.2 10.9 1.1 13.3 7.2 11.1 1.2 14.1 8.4 190 7 190 165 7.3 0 7.8 6.7 10/10/2006 13:40:00 11.9 1 15.3 8.8 11.9 1 14.9 8.8 12.4 1.1 15.3 9.1 191 6 192 165 7.3 0 7.5 7 10/10/2006 13:50:00 11 1 14.1 7.6 11 1 14.1 7.2 11.2 1.1 13.7 8 191 9 201 165 7.7 0.3 8.3 7.3 10/10/2006 14:00:00 11.6 1 14.5 9.1 11.3 1 14.1 8.8 12 1 14.5 9.5 179 6 182 165 7.5 0.1 8 6.7 10/10/2006 14:10:00 10.5 0.9 12.6 7.6 10.2 0.8 11.8 7.6 10.9 1 13 8 171 11 173 165 7.6 0 7.8 7.5 10/10/2006 14:20:00 10.5 0.9 13.3 8.4 10.3 0.8 13 8 10.9 0.9 14.1 9.1 170 10 165 165 7.6 0.2 8 7.3 10/10/2006 14:30:00 11.4 1 14.5 8.8 11 1 13.7 9.1 11.7 1 14.1 9.1 170 9 178 165 8.3 0 8.8 8 10/10/2006 14:40:00 11.5 0.9 13.3 9.1 11.2 0.8 13 8.8 11.8 0.9 13.7 9.5 172 8 178 165 7.7 0.1 8.3 7 10/10/2006 14:50:00 11.3 0.9 13.3 8.8 11 0.8 13 8.8 11.4 1 14.1 8.8 171 5 180 165 8.1 0 8.3 7.5 10/10/2006 15:00:00 9.1 1.5 13.3 5.7 9 1.5 13.3 6.1 9.4 1.5 14.1 6.5 182 11 212 165 8 0 8.3 7.5 10/10/2006 15:10:00 11.9 2.5 18.7 6.8 11.8 2.5 18.3 6.5 12.2 2.4 19.1 8 182 10 188 165 7.8 0.1 8.3 7.3 10/10/2006 15:20:00 14.3 2.4 19.9 8.8 14.3 2.3 19.9 8.8 14.5 2.3 20.2 9.5 192 7 180 165 6.6 0.1 7.3 6.2 10/10/2006 15:30:00 12.3 1.3 16.4 8.8 12.3 1.3 16.1 8.4 12.4 1.4 16.1 8.4 189 9 190 165 6.6 0.1 7.3 6.2 10/10/2006 15:40:00 11 1.1 13.3 8 10.9 1.1 13.3 8 11.3 1 13.3 8.4 184 9 194 165 6.7 0 7.3 6.2 10/10/2006 15:50:00 12.5 1.3 16.1 9.1 12.4 1.3 15.6 8.8 12.7 1.3 16.1 9.5 187 9 183 165 6.9 0.1 7.3 6.5 10/10/2006 16:00:00 13.2 1.6 16.8 8.4 13.1 1.5 17.2 8.4 13.3 1.7 17.6 9.1 188 7 183 165 6.9 0.2 7.5 6.2 10/10/2006 16:10:00 11.2 1.4 14.9 7.6 11.3 1.4 14.5 7.6 11.4 1.5 15.6 7.6 194 8 187 165 6.7 0 7 6.2 10/10/2006 16:20:00 9.8 1 12.6 6.8 9.9 1.1 12.6 6.8 9.7 1.1 13.3 6.5 198 6 201 165 6.4 0.1 6.7 6.2 10/10/2006 16:30:00 11.8 1.1 14.9 9.1 11.8 1.1 14.5 8.8 11.7 1.1 14.9 8 193 7 200 165 6.4 0.1 7 6 10/10/2006 16:40:00 11.1 1.3 14.5 7.6 11.1 1.3 14.1 7.6 11.3 1.5 14.5 7.6 190 6 198 165 6.6 0 7 6 10/10/2006 16:50:00 8.9 1.2 11.5 5.3 8.7 1.2 11.5 5.3 8.9 1.1 11.5 6.1 186 7 199 165 6.7 0.1 7 6.2 10/10/2006 17:00:00 9.7 1.1 12.6 6.8 9.5 1 12.6 7.2 9.8 1.1 12.2 7.2 181 14 190 165 6.7 0 7 6.2 10/10/2006 17:10:00 9.5 1.1 12.6 6.5 9.4 1.2 12.6 6.1 9.5 1.1 11.8 6.5 187 10 198 165 6.8 0.1 7.3 6.2 10/10/2006 17:20:00 10.3 1.5 14.1 6.8 10.1 1.4 13.7 6.5 10.4 1.3 14.1 7.2 180 7 181 165 6.8 0.1 7.3 6.2 10/10/2006 17:30:00 12 1.3 15.3 8 11.7 1.2 14.9 8 12.2 1.3 15.3 9.5 180 7 180 165 6.9 0.1 7.3 6.2 10/10/2006 17:40:00 13.3 1.5 16.8 9.9 13.3 1.5 16.4 9.5 13.5 1.5 17.2 9.5 188 8 192 165 6.5 0.1 7 6 10/10/2006 17:50:00 12.4 1.4 16.1 8.8 12.5 1.4 16.1 9.5 12.6 1.5 16.1 9.5 192 6 198 165 6.3 0.2 6.7 5.7 10/10/2006 18:00:00 11.1 1.9 15.3 6.1 11.1 1.9 15.6 5.7 11.1 2.1 16.4 5.3 195 7 198 165 6.4 0.1 6.7 5.7 10/10/2006 18:10:00 6.6 1.4 11.1 3.4 6.7 1.3 10.7 3.8 6.7 1.3 10.7 3.4 203 11 191 165 6.2 0 6.5 6 10/10/2006 18:20:00 5.8 1.3 8.8 2.6 5.9 1.2 9.1 3 5.5 1.3 9.1 2.3 214 17 208 165 6.4 0 6.7 6 10/10/2006 18:30:00 6.2 1.5 9.9 2.6 6.3 1.5 9.9 3 6.2 1.5 10.3 2.6 211 13 200 165 6.5 0 6.7 6.2 10/10/2006 18:40:00 9.3 1.9 13.7 5.3 9.2 1.9 13.3 4.9 9.3 1.9 14.1 4.9 197 10 182 165 6.6 0 7 6.2 10/10/2006 18:50:00 10.3 1.8 14.5 6.1 10.4 1.9 14.5 6.1 10.3 1.9 14.5 6.1 195 8 191 165 6.8 0 7 6.5 10/10/2006 19:00:00 12.7 1.6 16.4 8.8 12.6 1.6 16.4 9.1 12.8 1.5 16.8 9.5 187 8 200 165 6.9 0 7.3 6.7 10/10/2006 19:10:00 13.6 1.7 17.6 9.1 13.4 1.6 16.8 8.8 13.7 1.5 17.6 10.7 182 8 185 165 6.9 0 7.3 6.7 10/10/2006 19:20:00 12.4 1.2 14.9 9.1 12.2 1.2 14.5 9.1 12.6 1.3 15.3 9.5 182 6 194 165 6.7 0 7 6.2 10/10/2006 19:30:00 12.3 1.2 14.9 8.8 12 1.2 14.5 8.8 12.4 1.2 15.6 9.5 180 6 180 165 6.7 0.1 7.3 6.2 10/10/2006 19:40:00 11.7 1 15.3 9.1 11.6 1 14.5 8.8 12 1.1 16.1 8.8 184 6 183 165 6.7 0.1 7 6.2 10/10/2006 19:50:00 12.8 1.4 16.8 8.8 12.6 1.3 16.1 8.8 13 1.5 16.4 8.8 182 9 165 165 6.6 0.1 7 6 10/10/2006 20:00:00 13.2 1.3 16.1 9.9 13.2 1.3 16.4 9.9 13.2 1.2 15.6 9.5 190 7 191 165 6.6 0.1 7 6.2 10/10/2006 20:10:00 14.1 1.1 16.1 10.7 14.1 1.1 16.4 11.1 14.4 1.1 16.4 10.7 190 6 189 165 6.6 0.1 7 6 10/10/2006 20:20:00 13.3 1 15.3 10.7 13.3 1 15.3 10.3 13.5 1.1 16.4 9.9 191 5 188 165 6.6 0.1 7 6.2 10/10/2006 20:30:00 12.1 0.8 14.5 9.9 12.1 0.8 14.5 10.3 12.3 1.1 15.3 9.1 189 5 193 165 6.6 0.1 7 6 10/10/2006 20:40:00 10.3 0.9 12.6 8.4 10.3 0.8 12.2 8.4 10.5 0.9 13 8.4 187 5 180 165 6.5 0.1 6.7 6 10/10/2006 20:50:00 11.4 1.2 14.1 7.2 11.4 1.2 13.7 8 11.8 1.3 14.5 8 190 6 193 165 6.7 0.1 7.3 6 10/10/2006 21:00:00 10 0.8 12.6 7.6 9.8 0.9 12.2 7.6 10.2 1 13.3 7.6 185 7 191 165 6.9 0.1 7.3 6.5 10/10/2006 21:10:00 9 1 11.5 6.5 8.8 1 11.1 6.5 9.2 1 11.5 7.2 176 6 180 165 6.8 0.1 7.3 6.2 10/10/2006 21:20:00 10 0.8 11.8 7.6 9.8 0.8 11.8 7.6 10.2 0.8 11.8 7.2 179 6 185 165 6.8 0.1 7 6.2 10/10/2006 21:30:00 9.4 0.8 11.1 7.2 9.1 0.8 11.1 6.8 9.5 0.8 11.5 7.2 179 6 174 165 6.9 0.1 7.3 6.2 10/10/2006 21:40:00 9 0.9 12.2 7.2 8.7 0.8 11.8 6.5 9.2 0.9 11.8 6.8 176 8 185 165 6.9 0.1 7 6.5 10/10/2006 21:50:00 9.4 0.8 11.8 7.2 9.1 0.8 11.5 7.2 9.7 0.8 12.2 7.2 172 7 174 165 6.8 0.1 7.3 6.2 10/10/2006 22:00:00 10.4 1 13 8.4 10.1 0.9 12.6 8 10.6 1 13.3 8 177 9 184 165 6.9 0.1 7.3 6.2 10/10/2006 22:10:00 10 0.9 12.6 8 9.9 0.8 12.2 7.6 10.3 0.9 13 8.4 184 7 191 165 6.9 0.1 7.3 6.2 10/10/2006 22:20:00 10.3 1 12.6 7.6 10.2 0.9 12.6 7.2 10.5 1 12.6 8 191 6 189 165 7 0 7.3 6.5 10/10/2006 22:30:00 8.7 1 10.7 6.1 8.6 1 10.7 6.1 9 1 11.5 6.1 190 6 193 165 7.1 0 7.3 6.7 10/10/2006 22:40:00 6.9 1 8.8 4.2 6.7 0.8 8.4 4.2 7.1 0.8 9.1 4.9 189 7 176 165 7 0 7.3 6.2 10/10/2006 22:50:00 7.5 0.9 9.5 4.6 7.3 1 9.9 4.6 7.7 0.9 9.9 5.3 183 9 199 165 7.1 0 7.3 6.5 10/10/2006 23:00:00 6.9 0.9 9.5 4.6 6.7 0.9 9.1 4.6 7.2 0.8 9.5 4.9 179 8 162 165 7.1 0 7.3 6.5 10/10/2006 23:10:00 8.9 1.4 11.8 6.1 8.6 1.4 11.5 5.7 9.1 1.5 12.2 6.1 179 8 179 165 6.9 0.1 7.3 6.2 10/10/2006 23:20:00 9.3 1.1 12.6 6.5 9 1 12.2 6.8 9.3 1 12.6 6.8 182 7 182 165 6.9 0.1 7.3 6.2 10/10/2006 23:30:00 10.8 1.1 13.7 8 10.5 1.1 13.7 8 10.8 1 14.5 7.2 184 6 189 165 6.9 0.1 7.3 6.2 10/10/2006 23:40:00 10.8 1.4 14.1 6.5 10.6 1.3 13.7 6.1 10.7 1.3 14.1 8 185 7 196 165 7.1 0.1 7.3 6.2 10/10/2006 23:50:00 11.6 1.7 16.1 7.2 11.5 1.7 15.6 7.6 11.7 1.7 15.6 8 187 8 193 165 7.1 0 7.5 6.5 10/11/2006 00:00:00 9.4 1.1 11.8 5.7 9.4 1.2 11.8 5.7 9.8 1.2 12.6 6.5 195 7 200 165 7 0.2 7.5 6.2 10/11/2006 00:10:00 10.1 1.1 11.8 7.2 10 1.1 11.8 6.8 10.2 1.2 12.6 7.6 190 5 197 165 6.8 0 7 6.7 10/11/2006 00:20:00 11.1 1.2 14.1 8 11 1.2 14.1 8 11.3 1.1 14.1 8.8 189 6 211 165 6.9 0 7.3 6.2 10/11/2006 00:30:00 10.5 1.1 13.3 6.8 10.5 1.1 13.3 7.2 10.5 1.2 13.3 7.2 195 7 198 165 6.9 0 7.3 6.2 10/11/2006 00:40:00 11.4 1 14.1 8.4 11.4 1 13.7 8.4 11.6 1.1 14.5 8.4 192 6 194 165 6.9 0 7.3 6.7 10/11/2006 00:50:00 11.5 1.7 16.1 6.8 11.4 1.7 16.1 7.2 11.6 1.9 16.4 7.6 189 8 196 165 6.9 0.1 7.3 6.7 10/11/2006 01:00:00 10.9 1.1 14.1 7.2 10.9 1.1 13.7 7.2 10.9 1.1 13.7 8 195 6 196 165 6.6 0 7 6.2 10/11/2006 01:10:00 10.5 1.1 13 7.6 10.4 1.1 13 7.6 10.6 1.1 13.3 7.6 188 7 195 165 6.6 0 6.7 6.2 10/11/2006 01:20:00 9.6 1.3 12.6 6.1 9.4 1.3 12.6 5.7 9.7 1.4 13.3 6.5 183 8 189 165 6.4 0 6.7 6.2 10/11/2006 01:30:00 10.6 1.1 13.3 8 10.6 1.2 13.3 7.6 10.9 1.3 14.1 8 186 7 189 165 6.4 0.1 6.7 6 10/11/2006 01:40:00 9.8 1.1 13 7.2 9.7 1.1 12.6 7.2 9.9 1.2 13 6.5 190 7 191 165 6.3 0 6.7 6 10/11/2006 01:50:00 9.3 1 11.8 5.7 9.1 1.1 11.1 5.7 9.5 1.1 12.2 6.5 185 8 173 165 6.2 0 6.2 6 10/11/2006 02:00:00 8.9 1 11.8 5.7 8.8 1.1 11.1 5.7 8.9 1.1 11.8 5.7 189 8 184 165 6.2 0 6.7 6 10/11/2006 02:10:00 8.7 1.1 11.1 5.3 8.6 1.1 11.1 5.3 8.7 1.2 11.5 6.1 194 6 201 165 6.4 0 6.7 6.2 10/11/2006 02:20:00 8.9 1 11.5 6.1 8.7 0.9 11.5 6.1 8.9 0.9 11.5 6.8 189 7 199 165 6.6 0 7 6.2 10/11/2006 02:30:00 9.2 0.8 11.5 6.8 9.2 0.8 11.1 6.8 9.3 0.8 11.1 7.6 194 5 196 165 6.6 0 7 6.5 10/11/2006 02:40:00 8.4 0.8 10.7 6.5 8.4 0.8 10.7 6.1 8.6 0.7 10.7 6.5 196 6 193 165 6.7 0 7 6.5 10/11/2006 02:50:00 8.7 0.9 11.1 6.8 8.5 0.9 11.1 6.5 8.9 0.9 11.8 6.5 188 6 188 165 6.7 0 7 6.5 10/11/2006 03:00:00 8.4 0.8 10.7 6.5 8.3 0.8 10.7 6.8 8.7 0.8 11.1 6.1 188 6 203 165 6.7 0 7 6.5 10/11/2006 03:10:00 8.4 0.8 11.1 6.5 8.2 0.8 10.7 6.1 8.7 0.8 11.5 6.8 183 6 181 165 6.5 0 6.7 6.2 10/11/2006 03:20:00 9.8 0.8 11.8 7.6 9.5 0.7 11.5 7.2 9.8 0.8 11.8 6.5 182 6 178 165 6.6 0 7 6.2 10/11/2006 03:30:00 9.9 0.9 11.8 8 9.6 0.8 11.5 7.6 10.1 0.8 11.8 6.8 179 5 181 165 6.6 0 6.7 6.5 10/11/2006 03:40:00 8.8 1 10.7 6.5 8.6 0.9 10.7 6.5 8.9 1 11.1 6.8 179 4 177 165 6.5 0 6.7 6.2 10/11/2006 03:50:00 7.8 0.7 9.5 5.7 7.6 0.7 9.1 5.3 7.9 0.8 9.9 6.1 184 5 189 165 6.4 0 6.7 6 10/11/2006 04:00:00 8.4 0.5 10.3 6.8 8.3 0.5 9.9 6.8 8.7 0.5 9.9 7.2 187 5 186 165 6.4 0 6.7 5.7 10/11/2006 04:10:00 8.8 0.6 10.7 6.8 8.8 0.6 10.3 7.2 9.2 0.7 11.1 7.6 186 5 189 165 6.6 0 6.7 6.2 10/11/2006 04:20:00 9.1 0.8 11.8 7.6 9 0.8 11.5 7.2 9.3 0.8 11.5 7.2 182 5 187 165 6.7 0 7 6.2 10/11/2006 04:30:00 7.8 1.1 10.7 5.7 7.6 1 9.9 5.3 8 1.1 10.7 5.7 180 6 178 165 6.7 0 7 6.2 10/11/2006 04:40:00 6.3 0.8 8 4.2 6.2 0.8 7.6 4.2 6.6 0.9 8.8 4.2 183 6 192 165 6.7 0 7 6.2 10/11/2006 04:50:00 7.3 1.3 10.3 3.8 7.3 1.3 10.3 3.8 7.3 1.3 11.5 4.6 194 8 200 165 6.9 0 7.3 6.5 10/11/2006 05:00:00 7.3 1.2 10.3 4.9 7.4 1.2 10.3 4.6 7.5 1.2 10.7 4.9 198 6 196 165 6.9 0 7.5 6.7 10/11/2006 05:10:00 7.2 1 9.9 4.9 7.1 1 9.5 4.9 7.3 1 10.3 5.7 191 8 187 165 6.8 0 7 6.2 10/11/2006 05:20:00 5.5 1 8.4 3.4 5.4 1 8.4 3.4 5.8 1 8.8 3.8 187 6 190 165 6.7 0 7 6.2 10/11/2006 05:30:00 6.4 1.1 9.1 3.4 6.3 1.1 9.1 3.4 6.6 1.1 8.8 4.2 190 7 195 165 6.6 0 7 6.2 10/11/2006 05:40:00 7 1.1 9.9 4.6 7.1 1 10.3 4.6 7.2 1.2 10.3 4.9 203 6 203 165 6.9 0.1 7.3 6.5 10/11/2006 05:50:00 6.5 1.1 9.1 3.8 6.5 1.1 9.5 3.8 6.6 1.1 9.9 4.2 202 8 206 165 7.1 0 7.3 6.7 10/11/2006 06:00:00 4.5 1 7.2 2.6 4.4 1 7.2 2.3 4.5 0.8 6.8 2.6 193 12 203 165 7 0.1 7.5 6.7 10/11/2006 06:10:00 3.3 0.8 5.7 1.9 3.2 0.8 5.3 1.5 3.5 0.7 6.1 2.3 178 13 189 165 6.9 0.1 7.3 6.7 10/11/2006 06:20:00 4.8 1.6 8 1.9 4.8 1.5 8 1.9 5 1.3 8.4 2.3 187 10 198 165 7 0 7.3 6.7 10/11/2006 06:30:00 5.3 0.7 7.2 3.4 5.1 0.7 7.2 3.4 5.5 0.7 8 3.8 172 15 179 165 7.1 0 7.3 7 10/11/2006 06:40:00 4.8 1.3 9.1 1.5 4.6 1.3 8.8 0.7 4.8 1 8.8 2.6 158 14 165 165 6.9 0.1 7.3 6.7 10/11/2006 06:50:00 4.8 1.1 8.8 2.6 4.6 1.1 8.4 2.6 5.1 1.1 8.8 3.4 168 13 191 165 7 0 7.3 7 10/11/2006 07:00:00 5.9 1.1 8.8 2.3 5.8 1.1 8 2.3 5.8 1.2 8.4 1.9 187 15 184 165 6.9 0 7.3 6.7 10/11/2006 07:10:00 7.3 0.9 9.9 4.6 7.1 0.9 9.1 4.2 7.4 0.8 10.3 5.7 194 8 194 165 7.1 0 7.3 7 10/11/2006 07:20:00 8.5 1.4 12.2 5.3 8.4 1.5 12.2 5.3 8.7 1.4 11.8 5.7 197 8 205 165 7.2 0 7.5 7 10/11/2006 07:30:00 9.2 1 11.8 6.5 9.2 1 11.8 6.5 9.2 1 11.8 6.5 197 6 197 165 7.2 0 7.3 7 10/11/2006 07:40:00 8.6 1.2 12.2 5.7 8.5 1.3 12.2 5.3 8.7 1.2 12.2 5.7 193 7 202 165 7.3 0 7.5 7 10/11/2006 07:50:00 6.7 1 9.9 4.9 6.4 1 9.5 4.6 6.8 0.9 9.1 4.9 189 7 188 165 7.2 0 7.5 7 10/11/2006 08:00:00 5 1.4 8.4 3 4.8 1.3 8.4 2.3 5.1 1.2 8.4 3 171 11 173 165 6.9 0.1 7.5 6.7 10/11/2006 08:10:00 4.4 0.5 5.7 3 4.2 0.5 5.7 3 4.7 0.5 6.1 3.4 162 8 164 165 7 0 7.3 6.7 10/11/2006 08:20:00 5.6 1.2 9.1 3 5.3 1.2 8.4 3 5.8 1.2 9.1 3.8 166 12 168 165 7.2 0 7.3 7 10/11/2006 08:30:00 4.1 0.9 6.1 1.9 4 0.8 6.1 1.9 4.3 0.7 5.7 2.6 175 11 188 165 7.2 0 7.5 7 10/11/2006 08:40:00 5 0.7 6.8 3.4 4.9 0.7 6.5 3 5 0.7 6.8 2.6 190 8 184 165 7.4 0.1 7.8 6.7 10/11/2006 08:50:00 5.5 0.8 7.6 3.4 5.4 0.8 7.2 3.4 5.8 0.7 8 4.2 186 12 171 165 7.8 0.3 8.5 7 10/11/2006 09:00:00 5.6 0.7 8 4.2 5.4 0.7 8 3.8 5.9 0.6 7.6 4.2 182 10 178 165 8 0.1 8.5 7.5 10/11/2006 09:10:00 5.8 0.8 7.6 3.4 5.7 0.8 7.2 3.4 5.8 0.8 7.6 4.2 189 11 186 165 7.8 0.1 8 7.3 10/11/2006 09:20:00 5.3 0.8 7.2 2.6 5.2 0.8 7.2 2.6 5.5 0.8 7.2 3.8 191 8 190 165 7.8 0 8.3 7.5 10/11/2006 09:30:00 5.9 0.7 8 4.2 5.9 0.7 8 3.8 6.1 0.7 8 4.6 193 8 196 165 7.8 0 8.3 7.5 10/11/2006 09:40:00 6.7 1.1 9.9 4.2 6.6 1.1 9.9 4.2 6.7 1.2 10.7 4.6 186 9 187 165 8 0 8.5 7.5 10/11/2006 09:50:00 6.8 1 9.1 4.2 6.6 1 9.1 4.2 7.1 1 10.3 4.9 183 9 189 165 8.6 0.2 9 8 10/11/2006 10:00:00 7.3 0.8 9.1 4.9 7 0.7 8.4 4.9 7.6 0.8 9.5 5.3 175 8 178 165 9 0 9.3 8.5 10/11/2006 10:10:00 6.8 0.9 9.1 4.2 6.5 0.8 8.8 4.2 7.1 0.8 9.1 5.3 172 9 164 165 9.1 0.2 9.6 8.5 10/11/2006 10:20:00 6.7 0.9 9.1 3.8 6.4 0.9 8.8 3.4 6.9 0.7 8.8 4.9 173 9 165 165 9.1 0.2 9.6 8.5 10/11/2006 10:30:00 6.6 0.6 7.6 4.9 6.3 0.5 7.6 4.9 6.9 0.6 8.8 5.3 168 6 164 165 8.9 0 9 8.8 10/11/2006 10:40:00 5.8 0.9 7.6 3.4 5.5 0.9 7.2 3.4 6.1 0.9 8.4 3.4 178 7 171 165 8.9 0.2 9.6 8.5 10/11/2006 10:50:00 6.3 1 8.4 4.2 6.1 1 8.4 4.2 6.6 1 8.8 3.8 176 7 181 165 9.7 0.1 10.1 9.3 10/11/2006 11:00:00 9.1 1 11.8 6.8 8.8 1 11.5 6.1 9.3 1.2 12.6 6.5 177 7 183 165 10 0.2 10.6 9.3 10/11/2006 11:10:00 9.6 1 13.7 7.2 9.3 1 13.7 7.2 9.9 1 12.6 7.2 176 7 182 165 10 0 10.3 9.8 10/11/2006 11:20:00 8.5 1 11.8 6.5 8.2 1 11.1 6.1 9 1.1 12.2 6.5 173 7 174 165 9.9 0 10.3 9.6 10/11/2006 11:30:00 8.4 0.9 11.8 6.1 8 0.9 11.1 5.7 8.7 0.8 11.1 6.1 172 7 165 165 10.2 0.1 10.6 9.6 10/11/2006 11:40:00 8.7 0.8 11.5 6.1 8.4 0.8 11.5 6.5 9.1 1 11.8 6.5 176 9 160 165 10.5 0.1 11.1 10.3 10/11/2006 11:50:00 9.1 1.5 12.6 4.9 8.9 1.4 12.2 4.6 9.4 1.5 13 5.3 182 8 187 165 10.9 0.2 11.4 10.6 10/11/2006 12:00:00 8.8 1 11.8 5.7 8.6 1.1 11.5 5.7 9.2 1.2 13 6.1 179 11 184 165 10.9 0 11.1 10.6 10/11/2006 12:10:00 8.1 1.2 11.8 4.2 7.9 1.2 11.5 4.9 8.3 1.2 11.8 5.3 184 11 163 165 11.2 0.1 11.7 10.9 10/11/2006 12:20:00 8.8 1 11.5 5.7 8.6 1 11.1 5.3 9.1 1.1 12.2 6.1 180 14 180 165 10.7 0.3 11.9 10.3 10/11/2006 12:30:00 9.4 1.2 12.6 5.7 9.2 1.2 12.2 5.7 9.6 1.2 12.6 6.1 178 9 191 165 10.5 0.3 11.1 10.1 10/11/2006 12:40:00 8.9 1 11.5 5.3 8.6 1.1 11.5 6.1 9 1 11.8 6.5 181 10 188 165 11.2 0.2 11.7 10.9 10/11/2006 12:50:00 8.6 1.1 11.5 3.8 8.4 1.2 11.1 4.6 8.8 1.2 11.8 5.7 182 11 184 165 11.3 0.1 11.9 11.1 10/11/2006 13:00:00 8.9 1.2 11.8 5.7 8.8 1.2 11.5 5.7 9.3 1.3 12.6 6.5 183 11 175 165 11.4 0 11.7 11.1 10/11/2006 13:10:00 9.3 1.3 12.2 6.1 9 1.3 11.8 6.1 9.6 1.5 13 6.1 177 11 180 165 11.1 0 11.4 10.9 10/11/2006 13:20:00 6.4 1.2 9.5 3.8 6.3 1.2 9.5 3.4 6.8 1.1 9.1 4.2 191 13 185 165 11.8 0.2 12.5 11.1 10/11/2006 13:30:00 6.9 1 9.9 4.2 6.9 1 9.9 4.2 7.1 1 11.1 4.6 187 13 197 165 11.9 0.1 12.5 11.7 10/11/2006 13:40:00 7.4 1 10.3 5.3 7.3 1 10.7 4.9 7.6 1.1 10.7 4.6 185 15 171 165 11.9 0.1 12.2 11.7 10/11/2006 13:50:00 7.7 0.8 9.9 5.3 7.5 0.9 9.5 4.9 8 0.9 10.3 4.9 187 10 178 165 11.7 0 11.9 11.1 10/11/2006 14:00:00 8 1 11.1 5.3 7.9 1 11.5 4.9 8.4 1 10.7 5.7 179 9 165 165 11.6 0.2 11.9 11.4 10/11/2006 14:10:00 8.2 1.2 10.7 4.2 8.1 1.2 10.7 4.6 8.8 1.2 11.8 5.3 180 10 190 165 11.4 0.1 11.9 11.1 10/11/2006 14:20:00 7.2 1.1 10.3 4.2 7 1.1 10.3 3.8 7.5 1.2 10.3 4.9 183 10 201 165 11.3 0.1 11.7 11.1 10/11/2006 14:30:00 6.8 0.7 9.1 4.6 6.6 0.7 8.8 4.6 7.2 0.8 9.1 4.9 177 12 189 165 11.3 0 11.7 11.1 10/11/2006 14:40:00 7.7 0.9 9.9 5.7 7.4 0.9 9.9 5.3 8 1 10.3 5.3 177 9 165 165 11.3 0.2 11.7 10.9 10/11/2006 14:50:00 8.4 0.9 10.7 6.1 8.2 0.8 10.7 5.7 8.7 1 10.7 5.7 178 8 174 165 11.7 0 11.9 11.4 10/11/2006 15:00:00 7.9 0.9 10.3 5.7 7.8 0.9 10.3 5.3 8.4 0.9 10.7 6.1 183 8 185 165 11.7 0 11.9 11.7 10/11/2006 15:10:00 7.9 1 10.3 5.7 7.8 1 9.9 5.3 8.2 1 10.7 5.7 186 9 191 165 11.5 0.2 11.9 11.1 10/11/2006 15:20:00 6.9 0.8 8.8 4.9 6.7 0.8 8.4 4.6 7.3 0.8 9.5 5.3 184 9 191 165 11.8 0 12.2 11.4 10/11/2006 15:30:00 6.7 1 9.1 4.2 6.6 1 9.5 3.8 7.1 1 9.5 3.8 188 9 201 165 11.9 0 12.2 11.7 10/11/2006 15:40:00 7.5 0.9 9.9 4.6 7.4 0.9 9.5 4.9 7.8 1 10.3 4.9 189 9 194 165 11.7 0 11.9 11.7 10/11/2006 15:50:00 7.6 1 10.3 4.6 7.4 1 10.3 4.6 7.9 1 10.3 5.7 183 9 205 165 11.5 0.1 11.9 11.4 10/11/2006 16:00:00 7.9 0.9 9.9 5.3 7.6 0.9 9.9 5.3 8.3 1 11.1 5.3 179 8 179 165 11.3 0 11.4 11.1 10/11/2006 16:10:00 7.8 1 9.9 5.3 7.5 0.9 9.5 4.9 8 1 9.9 5.7 176 10 197 165 10.7 0.3 11.4 10.3 10/11/2006 16:20:00 6.8 1.2 9.5 3.8 6.6 1.2 9.5 3.8 6.9 1.1 9.5 3.8 183 9 189 165 10.3 0 10.9 10.3 10/11/2006 16:30:00 7.8 1 10.3 5.7 7.6 0.9 9.9 5.3 7.9 1 10.7 5.7 183 12 185 165 9.9 0 10.6 9.8 10/11/2006 16:40:00 7.3 0.8 9.1 5.3 7.2 0.8 8.8 4.9 7.4 0.8 9.5 5.3 186 6 182 165 10 0 10.3 9.8 10/11/2006 16:50:00 7.5 0.9 9.5 5.3 7.3 0.8 9.1 5.3 7.7 0.9 9.9 5.3 183 6 184 165 9.4 0.1 9.8 9 10/11/2006 17:00:00 7 1.2 9.1 4.6 6.9 1.1 9.1 4.6 7.1 1.1 9.5 4.6 181 8 181 165 9 0 9.3 8.5 10/11/2006 17:10:00 5.7 1 8.8 3.8 5.6 1 8 3.4 6 0.9 8.4 3.8 178 8 183 165 9 0 9 8.8 10/11/2006 17:20:00 5.2 0.7 7.2 3.4 5.1 0.7 6.8 3.4 5.4 0.6 7.2 3.8 176 9 182 165 8.7 0.1 9 8.5 10/11/2006 17:30:00 5.1 0.7 6.8 3.4 5 0.7 6.5 3 5.4 0.7 6.8 3.4 181 6 178 165 8.4 0.1 8.8 8 10/11/2006 17:40:00 5.2 0.6 6.8 3.4 5.1 0.6 6.8 3.4 5.4 0.5 6.8 4.2 179 8 184 165 8.3 0.2 8.8 7.8 10/11/2006 17:50:00 5 0.6 6.8 3.4 4.8 0.6 6.5 3 5.2 0.6 7.6 3.8 177 7 189 165 8.3 0.2 8.8 8 10/11/2006 18:00:00 4.3 0.4 5.3 3.4 4.1 0.4 5.3 3 4.6 0.5 5.7 3.4 178 7 176 165 8.2 0 8.5 7.8 10/11/2006 18:10:00 5.5 0.6 6.8 4.2 5.3 0.5 6.8 4.2 5.7 0.5 6.8 4.6 181 4 189 165 8 0 8.5 7.5 10/11/2006 18:20:00 5.5 0.4 6.5 4.6 5.3 0.4 6.5 4.6 5.7 0.4 6.8 4.9 177 5 180 165 8 0.1 8.3 7.3 10/11/2006 18:30:00 4.2 0.6 5.3 3 3.9 0.6 5.3 2.6 4.4 0.6 5.7 3.4 173 5 172 165 7.8 0 8 7.5 10/11/2006 18:40:00 4.4 0.8 6.1 3 4.2 0.8 6.1 2.6 4.5 0.7 6.1 3.4 186 8 183 165 7.6 0 8.3 7.3 10/11/2006 18:50:00 5.3 0.5 6.8 3.8 5.3 0.5 6.5 4.2 5.5 0.5 6.5 4.6 193 6 187 165 7.7 0 8 7.5 10/11/2006 19:00:00 6.6 0.7 8.4 4.2 6.6 0.7 8 4.2 6.7 0.7 8 4.6 196 6 194 165 7.9 0 8.3 7.8 10/11/2006 19:10:00 7.3 0.6 8.4 5.3 7.3 0.6 8.8 5.7 7.2 0.8 8.8 5.3 198 3 198 165 7.8 0 8 7.5 10/11/2006 19:20:00 5.5 0.7 7.2 4.2 5.6 0.7 7.2 4.2 5.5 0.8 7.6 4.2 205 5 202 165 7.7 0 8 7.3 10/11/2006 19:30:00 4.7 0.8 7.2 2.3 4.7 0.7 7.2 2.3 4.8 0.6 6.5 3.4 201 8 199 165 7.8 0.1 8.3 7.3 10/11/2006 19:40:00 5.7 0.5 6.8 4.6 5.7 0.5 6.8 4.6 5.8 0.6 7.2 4.2 197 6 189 165 7.8 0 8.3 7.3 10/11/2006 19:50:00 5.7 0.6 7.2 3.8 5.7 0.6 6.8 3.4 5.8 0.5 7.2 4.2 195 5 201 165 7.7 0 8 7.3 10/11/2006 20:00:00 6.4 0.8 8 3.8 6.4 0.8 8 3.8 6.6 0.9 8.4 4.2 191 8 194 165 7.8 0.1 8 7.3 10/11/2006 20:10:00 5.2 0.6 7.6 2.6 4.9 0.5 6.8 2.6 5.4 0.6 6.5 3 171 10 177 165 7.3 0.1 8 7 10/11/2006 20:20:00 5.6 1.1 7.6 3 5.5 1.1 7.2 2.3 5.7 1.1 7.6 3 188 6 187 165 7.2 0.2 7.8 6.7 10/11/2006 20:30:00 7 0.4 8.4 6.1 6.9 0.4 8 5.7 7.2 0.4 8 6.1 185 5 188 165 7.4 0.1 7.8 7 10/11/2006 20:40:00 7.5 0.8 9.5 6.1 7.5 0.8 9.5 6.1 7.7 0.8 9.9 6.1 188 3 191 165 7.4 0.1 7.8 7 10/11/2006 20:50:00 8.7 0.5 9.9 7.2 8.8 0.5 9.9 7.2 9 0.6 10.3 7.6 193 3 189 165 7.6 0 7.8 7 10/11/2006 21:00:00 7.7 0.6 9.1 6.5 7.8 0.6 9.5 6.5 8 0.6 9.9 6.1 196 3 195 165 7.6 0 8 7.3 10/11/2006 21:10:00 7.7 0.6 9.1 5.7 7.6 0.6 8.8 5.7 7.9 0.6 9.5 6.1 189 5 193 165 7.5 0.1 7.8 7.3 10/11/2006 21:20:00 6 0.7 7.6 4.6 6.1 0.7 8 4.6 6.2 0.7 8.4 4.2 195 3 194 165 7.6 0 7.8 7.3 10/11/2006 21:30:00 6.3 0.9 8.8 4.6 6.2 0.8 8.8 4.6 6.4 0.8 8.4 4.9 190 8 188 165 7.5 0.2 8 7 10/11/2006 21:40:00 5.1 0.9 7.6 3 5 0.9 7.2 2.6 5.2 1 7.2 3 182 8 185 165 7.4 0.2 8 7 10/11/2006 21:50:00 2.8 0.6 4.9 1.9 2.7 0.7 4.9 1.5 2.9 0.5 4.6 1.9 183 11 193 165 7.2 0 7.5 6.7 10/11/2006 22:00:00 5.3 0.8 6.8 3 5.2 0.8 6.8 3 5.3 0.9 6.8 3 194 7 194 165 7.3 0.1 7.5 7 10/11/2006 22:10:00 4 0.8 6.5 1.9 3.8 0.8 6.1 1.9 4.1 0.8 6.1 2.3 169 8 191 165 7.4 0 7.8 7 10/11/2006 22:20:00 1.3 0.7 3 0.4 1 0.6 2.6 0.4 1.6 0.6 2.6 0.4 182 11 180 165 7 0 7.3 6.7 10/11/2006 22:30:00 0.4 0.1 1.1 0.4 0.4 0 0.4 0.4 0.6 0.4 1.5 0.4 248 39 279 165 6.9 0.1 7.3 6.5 10/11/2006 22:40:00 1.6 0.7 3 0.4 1.4 0.7 2.6 0.4 2.2 0.7 3.4 0.4 213 33 193 165 7.4 0.1 7.8 7 10/11/2006 22:50:00 2.3 0.8 4.2 0.7 2 0.9 4.2 0.4 2.7 0.6 4.6 1.1 167 11 159 165 7.4 0.1 7.8 7.3 10/11/2006 23:00:00 2.6 0.6 3.8 1.1 2.4 0.6 3.8 0.7 2.9 0.4 3.8 1.9 180 15 164 165 7.4 0.1 7.8 7 10/11/2006 23:10:00 3.7 0.9 5.7 1.9 3.4 0.9 5.3 1.5 3.8 0.8 5.3 2.3 170 16 164 165 7.4 0.1 7.8 7 10/11/2006 23:20:00 4.4 0.5 5.3 2.6 4.1 0.5 5.3 2.3 4.4 0.6 5.7 3 173 7 179 165 7.4 0.1 7.8 7.3 10/11/2006 23:30:00 4.5 0.6 7.2 2.3 4.2 0.6 6.1 1.9 4.5 0.5 5.7 3 177 4 164 165 7.4 0 7.5 7 10/11/2006 23:40:00 4.3 0.8 6.8 2.6 4.1 0.8 6.5 2.6 4.2 0.8 6.5 2.6 186 7 177 165 7.4 0.1 7.5 7 10/11/2006 23:50:00 4.1 0.4 5.3 3.4 4.1 0.4 5.3 3.4 4.2 0.4 5.3 3 196 3 201 165 7.5 0 7.8 7.3 10/12/2006 00:00:00 3.4 0.5 4.6 2.3 3.3 0.5 4.6 2.3 3.5 0.5 4.9 2.6 192 5 204 165 7.6 0 7.8 7.3 10/12/2006 00:10:00 2.7 0.4 3.4 1.5 2.6 0.3 3.4 1.5 3 0.3 3.8 2.3 190 8 201 165 7.6 0 7.8 7.3 10/12/2006 00:20:00 3.3 0.6 4.9 2.3 3.2 0.6 4.6 2.3 3.4 0.5 4.6 2.6 197 6 193 165 7.7 0 8 7.5 10/12/2006 00:30:00 3.2 0.5 4.6 1.9 3 0.5 4.2 1.9 3.4 0.5 4.6 2.3 180 9 188 165 7.7 0 7.8 7.3 10/12/2006 00:40:00 3.6 0.4 4.6 3 3.4 0.4 4.2 2.6 3.9 0.3 4.6 3 163 3 165 165 7.5 0.1 7.8 7.3 10/12/2006 00:50:00 3.3 0.6 4.6 1.9 3 0.6 4.6 1.5 3.5 0.5 4.9 2.3 170 10 171 165 7.3 0.1 7.5 7 10/12/2006 01:00:00 5 0.8 6.5 3 4.7 0.7 6.1 3 5.1 0.8 6.8 3 172 6 166 165 7.2 0 7.5 6.7 10/12/2006 01:10:00 5.8 0.5 6.8 4.2 5.5 0.5 6.5 4.2 5.9 0.6 7.2 4.2 178 4 184 165 7.2 0 7.5 7 10/12/2006 01:20:00 5.6 0.7 7.2 3.8 5.4 0.6 6.8 3.8 5.7 0.6 7.2 4.2 178 5 175 165 7.1 0 7.3 6.7 10/12/2006 01:30:00 5.5 0.5 7.2 4.2 5.1 0.5 6.8 4.2 5.4 0.4 7.2 4.2 172 6 175 165 7.1 0 7.3 6.7 10/12/2006 01:40:00 6 0.5 7.2 4.9 5.7 0.4 6.8 4.6 5.9 0.4 7.6 4.9 175 5 166 165 7 0 7.3 6.5 10/12/2006 01:50:00 5.9 0.7 7.6 4.6 5.6 0.6 7.2 4.6 6 0.7 7.6 4.6 176 6 178 165 7.1 0 7.3 6.7 10/12/2006 02:00:00 4.9 0.5 6.1 3.8 4.7 0.5 6.1 3.8 5.2 0.5 6.1 3.8 179 8 179 165 6.9 0.1 7.3 6.5 10/12/2006 02:10:00 5.5 0.8 7.2 3.4 5.2 0.7 6.8 3 5.5 0.7 7.2 4.2 171 5 172 165 6.9 0.1 7.3 6.2 10/12/2006 02:20:00 6.3 0.5 7.2 5.3 6.1 0.4 6.8 4.9 6.4 0.5 7.2 4.9 168 12 165 165 6.9 0.1 7.3 6.2 10/12/2006 02:30:00 5.9 0.5 6.8 4.2 5.6 0.4 6.5 4.2 6 0.5 7.2 4.6 167 9 172 165 6.8 0.2 7.3 6.2 10/12/2006 02:40:00 5.2 0.4 6.1 3.8 4.9 0.4 5.7 3.8 5.4 0.4 6.5 4.2 171 11 170 165 6.7 0.2 7 6.2 10/12/2006 02:50:00 4 0.4 4.9 2.6 3.8 0.4 4.6 2.6 4.2 0.5 4.9 2.3 182 6 182 165 6.6 0.1 7 6.2 10/12/2006 03:00:00 4.5 0.7 5.7 3 4.2 0.6 5.7 2.6 4.6 0.6 6.1 3.4 176 7 189 165 6.6 0.1 7 6.2 10/12/2006 03:10:00 4.1 0.5 5.3 2.6 3.9 0.5 4.9 2.6 4.2 0.4 5.3 3 171 12 177 165 6.6 0.1 7 6.2 10/12/2006 03:20:00 4.9 0.4 5.7 3.8 4.8 0.4 5.7 3.8 4.9 0.4 6.1 3.8 173 5 165 165 6.6 0.1 7 6 10/12/2006 03:30:00 5.6 0.5 7.6 4.6 5.3 0.5 7.2 4.2 5.6 0.5 7.2 4.9 173 5 165 165 6.5 0.1 7 6 10/12/2006 03:40:00 5.7 0.5 7.2 4.6 5.5 0.5 7.6 4.6 5.8 0.5 7.2 4.2 171 5 171 165 6.6 0.1 7 6.2 10/12/2006 03:50:00 6.1 0.5 7.2 4.6 5.8 0.5 7.2 4.6 6.2 0.5 7.2 4.6 173 5 167 165 6.6 0 7 6.2 10/12/2006 04:00:00 5.9 0.5 6.8 4.6 5.6 0.4 6.5 4.2 6.1 0.4 7.2 4.6 170 10 178 165 6.6 0 7 6 10/12/2006 04:10:00 6.3 0.4 7.2 5.3 6 0.3 6.8 4.9 6.4 0.4 7.2 4.9 168 11 165 165 6.5 0 6.7 6 10/12/2006 04:20:00 6.9 0.6 8.4 5.7 6.6 0.6 8 5.3 7.1 0.5 8.4 6.1 170 5 175 165 6.4 0 6.7 5.7 10/12/2006 04:30:00 7.7 0.5 8.8 6.1 7.4 0.4 8.4 6.1 7.7 0.5 8.8 6.1 170 4 165 165 6.4 0.1 6.7 5.7 10/12/2006 04:40:00 8.1 0.7 9.5 6.5 7.8 0.6 9.1 6.1 8.1 0.6 9.5 6.5 169 7 166 165 6.4 0.1 6.7 5.7 10/12/2006 04:50:00 7.7 0.5 8.8 6.1 7.4 0.5 8.8 5.7 7.7 0.5 8.8 6.1 167 10 165 165 6.4 0.1 6.7 5.7 10/12/2006 05:00:00 6.7 0.7 8.4 5.3 6.4 0.7 8 4.9 6.8 0.7 8.4 5.3 169 3 179 165 6.4 0.1 7 5.7 10/12/2006 05:10:00 5.5 0.4 6.5 4.6 5.3 0.3 6.1 4.6 5.7 0.4 6.5 4.9 168 4 167 165 6.4 0.1 6.7 5.7 10/12/2006 05:20:00 6 0.5 7.2 4.6 5.8 0.5 6.8 4.6 5.9 0.4 6.8 4.6 170 4 170 165 6.4 0 6.7 6.2 10/12/2006 05:30:00 6.2 0.5 7.2 4.9 5.9 0.5 6.8 4.9 6.3 0.6 7.6 4.9 166 11 166 165 6.4 0 6.7 6.2 10/12/2006 05:40:00 6.4 0.4 7.2 4.9 6.2 0.4 6.8 4.6 6.4 0.5 7.6 4.6 162 4 164 165 6.4 0 6.7 6.2 10/12/2006 05:50:00 5.6 0.5 6.8 4.2 5.5 0.5 6.5 3.8 5.7 0.6 6.8 4.2 161 7 160 165 6.4 0 6.7 6.2 10/12/2006 06:00:00 5.5 0.4 6.5 4.2 5.3 0.4 6.1 4.2 5.7 0.4 6.8 4.6 162 4 169 165 6.4 0 6.7 6.2 10/12/2006 06:10:00 5.2 0.4 6.5 3.8 4.9 0.4 6.1 3.8 5.2 0.4 6.1 4.2 161 3 165 165 6.4 0 6.7 6.2 10/12/2006 06:20:00 4.8 0.4 5.7 3.4 4.5 0.4 5.3 3.4 5 0.3 5.7 3.8 163 3 162 165 6.4 0 6.7 6.2 10/12/2006 06:30:00 4.6 0.2 5.3 3.8 4.5 0.2 4.9 3.8 4.8 0.3 5.7 3.8 154 9 165 165 6.5 0 6.7 6 10/12/2006 06:40:00 4.6 0.3 5.3 4.2 4.5 0.3 5.3 3.8 4.8 0.3 5.3 4.2 149 3 149 165 6.5 0 6.7 6.2 10/12/2006 06:50:00 4.8 0.3 5.7 4.2 4.7 0.3 5.3 4.2 5.1 0.3 5.7 4.6 154 3 154 165 6.6 0 6.7 6 10/12/2006 07:00:00 4.9 0.3 5.7 4.2 4.8 0.3 5.7 4.2 5.2 0.3 5.7 4.6 155 3 151 165 6.6 0 6.7 6 10/12/2006 07:10:00 4.9 0.3 5.7 4.2 4.8 0.3 5.7 3.8 5.1 0.3 5.7 4.2 154 4 154 165 6.5 0 6.7 6 10/12/2006 07:20:00 4.7 0.4 5.3 3.8 4.5 0.4 5.3 3.8 5 0.3 5.7 4.2 155 3 156 165 6.5 0 6.7 6.2 10/12/2006 07:30:00 4 0.5 4.6 3 3.8 0.5 4.6 2.6 4.3 0.4 5.3 3.4 156 3 156 165 6.4 0 6.7 6.2 10/12/2006 07:40:00 3.6 0.3 4.2 2.6 3.5 0.3 4.2 2.6 3.9 0.4 4.6 2.6 152 4 154 165 6.4 0 6.7 6.2 10/12/2006 07:50:00 4.3 0.6 5.3 3 4.1 0.6 5.3 3 4.6 0.6 5.7 3.8 156 3 154 165 6.4 0 6.7 6.2 10/12/2006 08:00:00 5.8 0.4 6.5 4.9 5.7 0.4 6.5 4.9 6.1 0.4 6.8 4.9 153 2 154 165 6.4 0 6.7 6 10/12/2006 08:10:00 6.4 0.4 7.2 5.3 6.2 0.4 6.8 5.3 6.6 0.4 7.6 5.7 156 3 148 165 6.4 0 6.7 6.2 10/12/2006 08:20:00 5.4 0.3 6.1 4.2 5.2 0.3 6.1 4.2 5.6 0.3 6.5 4.9 156 2 157 165 6.3 0 6.5 6 10/12/2006 08:30:00 4.8 0.3 5.3 3.8 4.6 0.3 5.3 3.8 5 0.4 5.7 3.8 157 3 157 165 6.2 0 6.2 6 10/12/2006 08:40:00 5.1 0.4 5.7 4.2 5 0.4 5.7 4.2 5.3 0.4 6.1 4.6 155 3 150 165 6.3 0 6.5 6 10/12/2006 08:50:00 4.9 0.3 5.7 4.2 4.8 0.3 5.3 4.2 5.1 0.3 5.7 4.6 153 2 156 165 6.4 0 6.7 6.2 10/12/2006 09:00:00 4.5 0.3 5.3 3.8 4.3 0.3 5.3 3.4 4.6 0.4 5.3 3.8 155 3 154 165 6.4 0 6.7 6.2 10/12/2006 09:10:00 4.6 0.4 5.7 3.4 4.4 0.5 5.7 3.4 4.6 0.5 5.7 3.4 149 4 148 165 6.5 0 6.7 6.2 10/12/2006 09:20:00 5.4 0.5 6.5 4.2 5.4 0.5 6.5 4.2 5.5 0.5 6.8 4.6 150 5 151 165 6.7 0 7 6.5 10/12/2006 09:30:00 6.4 0.5 7.6 4.9 6.3 0.5 7.6 4.9 6.5 0.5 8 5.3 148 4 147 165 6.8 0 7 6.2 10/12/2006 09:40:00 6.1 0.5 7.2 4.9 6 0.5 7.2 4.9 6.2 0.6 7.2 4.9 152 4 144 165 6.7 0 7 6.2 10/12/2006 09:50:00 6.2 0.6 7.6 4.9 6.1 0.6 7.6 4.6 6.3 0.6 8 4.6 147 4 144 165 6.7 0 7 6 10/12/2006 10:00:00 6.4 0.7 8.4 4.6 6.3 0.7 8.4 4.6 6.3 0.6 8 4.6 143 7 126 165 6.7 0 7 6 10/12/2006 10:10:00 5.8 0.9 8 4.2 5.8 0.8 7.6 4.2 5.7 0.9 7.6 3.4 138 8 147 165 6.7 0 7 6.5 10/12/2006 10:20:00 6.7 0.9 9.1 4.2 6.7 0.9 9.5 4.2 6.6 0.9 8.8 3.8 134 8 122 165 6.7 0 7 6.5 10/12/2006 10:30:00 8.1 0.7 9.5 5.7 8.1 0.7 9.5 5.7 7.9 0.8 9.5 4.9 135 6 126 165 6.7 0 7 6.5 10/12/2006 10:40:00 7.5 0.8 9.9 5.3 7.4 0.8 10.3 4.9 7.3 0.8 9.5 5.3 133 6 132 165 6.7 0 7 6 10/12/2006 10:50:00 7.2 0.8 8.8 5.3 7.2 0.8 8.8 5.3 7.1 0.8 8.8 5.3 128 6 128 165 6.7 0 7 6.2 10/12/2006 11:00:00 7.1 0.6 9.1 5.7 7.2 0.7 9.1 4.9 7 0.7 9.1 4.9 126 6 128 165 6.7 0 7 6.5 10/12/2006 11:10:00 7.5 0.8 9.5 5.7 7.6 0.8 9.5 5.3 7.2 0.8 9.1 5.3 123 5 125 165 6.7 0 7 6 10/12/2006 11:20:00 8.6 0.7 10.3 6.5 8.6 0.7 10.3 6.1 8.3 0.8 10.3 6.1 122 5 128 165 6.7 0.1 7 6.2 10/12/2006 11:30:00 8.2 0.9 10.3 5.7 8.3 0.9 10.7 5.7 8.1 0.9 10.3 5.7 121 6 122 165 6.8 0.1 7 6.2 10/12/2006 11:40:00 7.7 0.7 9.9 5.3 7.7 0.8 10.3 5.3 7.4 0.8 9.5 5.3 121 5 118 165 6.9 0.1 7.3 6.5 10/12/2006 11:50:00 7.1 0.7 8.8 5.3 7.2 0.7 8.8 4.9 6.9 0.8 9.1 4.9 123 5 122 165 6.9 0.1 7.3 6.5 10/12/2006 12:00:00 6.6 0.5 8 4.9 6.6 0.6 8 5.3 6.3 0.6 8 4.6 121 6 117 165 6.9 0.1 7.3 6.5 10/12/2006 12:10:00 6.4 0.6 7.6 4.9 6.4 0.6 8 4.9 6.1 0.6 7.6 4.6 121 7 119 165 6.8 0.1 7 6.2 10/12/2006 12:20:00 6.4 0.7 8 4.2 6.5 0.7 8.4 4.2 6.2 0.8 8 4.6 115 7 112 165 6.7 0.1 7 6.2 10/12/2006 12:30:00 7.3 0.6 8.8 4.9 7.4 0.7 9.1 4.9 6.8 0.7 8.4 4.9 112 5 109 165 6.7 0.1 7 6.2 10/12/2006 12:40:00 7.1 0.8 9.9 4.9 7.2 0.8 9.9 5.3 6.8 1 9.9 4.2 118 6 121 165 6.8 0.1 7 6.2 10/12/2006 12:50:00 7.9 0.9 9.9 6.1 8 0.9 9.9 6.1 7.8 0.9 9.9 5.7 121 5 121 165 6.9 0.1 7 6.5 10/12/2006 13:00:00 7.7 0.7 9.5 5.3 7.7 0.7 9.5 5.3 7.4 0.8 9.5 4.9 125 5 128 165 6.9 0 7.3 6.5 10/12/2006 13:10:00 7.6 0.7 10.3 5.7 7.6 0.7 9.9 6.1 7.5 0.6 8.8 5.3 131 8 129 165 7.1 0 7.3 6.7 10/12/2006 13:20:00 7.6 0.7 9.5 4.6 7.6 0.7 9.1 4.2 7.4 0.7 8.8 5.3 129 7 136 165 7.1 0 7.3 6.5 10/12/2006 13:30:00 8.5 0.6 9.9 7.2 8.5 0.6 10.3 7.2 8.3 0.6 9.9 6.5 128 5 128 165 7.1 0 7.3 6.5 10/12/2006 13:40:00 8.8 0.8 10.7 6.8 8.9 0.7 10.7 6.8 8.6 0.7 10.3 6.8 126 5 124 165 7 0.1 7.3 6.2 10/12/2006 13:50:00 8.7 0.7 10.7 6.5 8.8 0.7 11.1 6.8 8.5 0.7 10.3 6.5 125 6 119 165 6.9 0.1 7.3 6.2 10/12/2006 14:00:00 8 1 11.1 5.7 8.1 1 10.7 6.1 7.7 1 11.1 5.3 120 6 126 165 6.9 0.1 7.3 6.2 10/12/2006 14:10:00 7.5 0.5 8.8 5.3 7.6 0.6 8.8 5.7 7.2 0.7 8.8 4.9 109 5 117 165 6.7 0 7 6.2 10/12/2006 14:20:00 6.9 0.5 8 4.9 7 0.5 8 5.3 6.5 0.7 8 3.8 101 4 95 165 6.7 0 7 6.2 10/12/2006 14:30:00 7.5 0.6 8.8 4.9 7.6 0.7 8.8 4.9 7 0.7 8.8 5.3 97 5 97 165 6.7 0 7 6.2 10/12/2006 14:40:00 7.4 0.8 9.5 4.6 7.5 0.9 9.5 4.6 6.8 1 8.8 4.2 95 6 92 165 6.7 0 6.7 6 10/12/2006 14:50:00 7.5 0.6 8.8 5.3 7.6 0.7 9.1 5.3 7.1 0.7 8.8 4.9 91 7 79 165 6.5 0 6.7 6.2 10/12/2006 15:00:00 7.8 0.6 9.1 5.7 8 0.7 9.5 5.7 7.3 0.7 9.1 5.3 86 5 84 165 6.4 0 7 6.2 10/12/2006 15:10:00 8.4 0.9 11.1 6.1 8.5 1 11.1 6.5 7.9 1 10.3 5.3 92 6 96 165 6.6 0 6.7 6.2 10/12/2006 15:20:00 9 1 11.1 6.1 9.2 1.1 11.5 6.5 8.5 1 11.1 5.7 96 6 89 165 6.6 0 6.7 6.2 10/12/2006 15:30:00 9.5 1.1 11.8 6.5 9.7 1.2 12.2 6.1 8.8 1.2 11.8 6.1 103 6 104 165 6.7 0 7 6.5 10/12/2006 15:40:00 9.1 1.1 11.1 6.1 9.3 1.1 11.5 5.7 8.5 1.2 11.1 5.3 100 6 103 165 6.6 0.1 7 6.2 10/12/2006 15:50:00 9 0.8 11.1 6.1 9.2 0.8 11.5 6.1 8.4 1 11.1 5.3 97 5 99 165 6.3 0 6.5 6 10/12/2006 16:00:00 8.3 0.8 9.9 6.1 8.5 0.9 10.3 5.3 7.7 1 9.9 4.9 98 6 103 165 6.3 0 6.5 6 10/12/2006 16:10:00 8.6 0.7 10.3 6.1 8.8 0.8 10.3 6.1 8.1 0.9 9.9 5.3 92 5 84 165 6.2 0 6.2 5.7 10/12/2006 16:20:00 8.3 0.8 9.9 5.3 8.5 0.9 9.9 5.3 7.9 0.9 9.5 5.3 89 4 87 165 6 0 6.2 5.7 10/12/2006 16:30:00 9.2 0.8 11.5 6.5 9.5 0.8 11.8 6.5 8.8 0.9 11.5 6.5 91 6 91 165 6.1 0 6.2 5.7 10/12/2006 16:40:00 9.2 0.7 11.1 7.2 9.4 0.7 11.1 7.2 8.7 0.9 11.1 6.1 96 5 94 165 6.1 0 6.2 5.7 10/12/2006 16:50:00 8.2 0.8 10.7 6.1 8.3 0.9 10.7 6.1 7.8 1 10.7 5.7 102 7 105 165 5.9 0 6 5.5 10/12/2006 17:00:00 7.6 0.7 9.1 4.9 7.7 0.7 9.1 5.3 7 0.9 8.8 4.6 98 4 94 165 5.9 0 6.2 5.5 10/12/2006 17:10:00 7.5 0.7 9.1 5.3 7.6 0.7 9.5 5.3 7.1 0.9 9.5 4.6 97 7 107 165 6 0 6 5.5 10/12/2006 17:20:00 7 0.5 8.8 5.3 7.1 0.6 9.1 5.7 6.9 0.7 8.8 4.9 90 6 89 165 6 0 6.2 5.7 10/12/2006 17:30:00 7.6 0.6 9.5 6.1 7.6 0.7 9.9 6.1 7.3 0.7 9.9 5.7 93 7 91 165 6.1 0 6.2 5.7 10/12/2006 17:40:00 8.8 0.8 11.1 6.5 9 0.9 12.2 6.8 8.4 1 11.1 5.3 105 8 110 165 6.2 0 6.2 6 10/12/2006 17:50:00 7.3 0.7 9.1 5.7 7.4 0.8 9.5 5.7 7 0.8 9.5 5.3 90 6 89 165 6.4 0 6.7 6.2 10/12/2006 18:00:00 8.1 0.7 9.5 5.3 8.2 0.8 9.5 4.9 7.6 0.8 9.5 4.9 96 6 91 165 6.4 0.1 7 6.2 10/12/2006 18:10:00 8.1 0.9 9.9 5.3 8.2 1 10.3 5.3 7.7 0.9 9.9 4.9 91 6 90 165 6.4 0 6.7 6.2 10/12/2006 18:20:00 8.1 0.6 9.5 5.7 8.1 0.7 9.5 5.7 7.7 0.8 9.5 5.7 81 5 89 165 6.4 0 6.7 6.2 10/12/2006 18:30:00 8.5 0.6 9.9 6.5 8.6 0.6 10.3 6.5 8.2 0.6 9.9 6.5 77 5 76 165 6.3 0 6.5 6.2 10/12/2006 18:40:00 7.6 0.8 9.5 5.3 7.7 0.9 9.9 5.3 7.2 0.8 9.1 4.9 72 7 77 165 6.3 0 6.5 6.2 10/12/2006 18:50:00 8 1 10.3 5.3 8.1 1.1 10.7 5.3 7.3 1 9.9 4.6 79 9 85 165 6.2 0 6.5 6 10/12/2006 19:00:00 9.3 1 11.5 6.8 9.5 1 11.8 6.8 8.6 0.9 11.1 6.1 83 5 81 165 6.4 0 6.7 6.2 10/12/2006 19:10:00 10.5 0.9 11.8 7.6 10.8 1 12.2 7.6 9.8 1.1 12.2 6.5 86 5 84 165 6.7 0 7 6.5 10/12/2006 19:20:00 10.2 0.9 12.6 7.2 10.4 1 12.6 7.2 9.5 1 11.8 6.5 83 6 84 165 6.7 0 7 6.7 10/12/2006 19:30:00 9 1.2 12.2 6.1 9.2 1.3 12.2 6.1 8.6 1.2 11.5 6.1 74 9 99 165 6.8 0 7 6.7 10/12/2006 19:40:00 9.7 1.2 11.8 6.5 9.9 1.3 12.2 6.1 9.3 1.2 11.8 6.1 78 6 81 165 6.9 0 7 6.7 10/12/2006 19:50:00 8.5 1 10.7 5.3 8.6 1.1 11.1 4.9 8.2 0.9 10.7 5.7 74 7 84 165 6.7 0 7 6.2 10/12/2006 20:00:00 8.2 1 10.7 5.3 8.3 1.1 11.1 5.3 7.7 1 10.7 5.7 75 9 78 165 6.6 0 6.7 6.2 10/12/2006 20:10:00 9.8 1.2 12.2 5.7 10 1.3 12.6 6.1 9.3 1.3 12.2 5.7 79 9 78 165 6.7 0 7 6.5 10/12/2006 20:20:00 11 1 13 8 11.2 1 13 8 10.3 1.1 13 7.6 86 6 82 165 6.9 0 7.3 6.7 10/12/2006 20:30:00 10.3 1.1 13.3 7.2 10.5 1.2 13.7 7.2 9.7 1.2 11.8 6.5 79 8 90 165 6.8 0.1 7 6.2 10/12/2006 20:40:00 10.6 1.3 14.1 7.2 10.9 1.4 14.5 7.2 10.2 1.2 14.5 7.2 81 7 91 165 6.7 0 7 6.2 10/12/2006 20:50:00 11.5 1.4 14.1 6.8 11.7 1.5 14.5 6.8 10.9 1.3 13.7 7.6 86 6 94 165 6.8 0 7 6.5 10/12/2006 21:00:00 11.3 1.2 14.5 8 11.5 1.2 14.9 8 10.8 1.3 14.1 7.6 88 5 95 165 6.9 0 7.3 6.7 10/12/2006 21:10:00 10.9 1.2 14.1 8 11.1 1.2 14.1 7.6 10.3 1.2 13.7 6.8 88 7 89 165 6.7 0 7 6.5 10/12/2006 21:20:00 9.1 1 11.8 5.7 9.3 1.1 11.8 5.7 8.8 1.1 11.5 6.5 78 7 81 165 6.8 0 7 6.5 10/12/2006 21:30:00 9.7 1.2 13 6.1 9.9 1.2 13.7 6.5 9.4 1.1 12.2 6.8 79 6 68 165 6.8 0.1 7 6.2 10/12/2006 21:40:00 10 1.3 13 6.5 10.2 1.3 13 5.7 9.5 1.3 13 6.1 80 7 81 165 6.7 0.2 7 6.2 10/12/2006 21:50:00 9.1 1.1 11.5 6.5 9.3 1.2 11.5 6.1 8.6 1.2 11.8 5.3 83 7 77 165 6.6 0.1 7 6 10/12/2006 22:00:00 9 1.1 12.6 6.5 9.1 1.2 12.2 6.5 8.6 1.1 11.8 5.7 88 9 91 165 6.7 0.1 7 6.2 10/12/2006 22:10:00 10 1.2 14.1 6.5 10.2 1.2 14.5 6.8 9.6 1.1 12.6 6.8 86 8 99 165 7 0.1 7.3 6.7 10/12/2006 22:20:00 10.5 1.4 13.7 6.5 10.8 1.4 14.1 6.8 10.2 1.3 13.7 6.5 85 7 73 165 7 0 7.3 6.7 10/12/2006 22:30:00 11.1 1.3 13.7 6.8 11.4 1.3 14.5 7.2 10.8 1.3 13.7 7.2 87 8 92 165 7.1 0.1 7.3 7 10/12/2006 22:40:00 9.6 1.1 12.2 6.1 9.9 1.2 12.2 6.5 9.3 1 11.5 6.5 83 7 94 165 7.1 0 7.3 7 10/12/2006 22:50:00 9.6 1 11.8 6.8 9.9 1 12.2 6.1 9.4 1.1 12.2 6.1 78 7 78 165 7.2 0 7.5 7 10/12/2006 23:00:00 10.6 1.4 13.7 6.5 10.9 1.5 13.7 6.5 10.3 1.5 13.7 6.1 82 7 81 165 7.1 0 7.5 7 10/12/2006 23:10:00 11.2 1.1 14.1 8.4 11.5 1.2 14.5 8.4 10.8 1.3 14.5 7.6 79 6 84 165 7.2 0 7.3 6.7 10/12/2006 23:20:00 9.3 1.9 13.3 5.3 9.5 2 13.7 4.9 9.1 1.7 13 4.9 77 8 87 165 6.9 0.1 7.3 6.7 10/12/2006 23:30:00 10.7 1.4 13.7 6.5 11 1.5 14.1 6.8 10.4 1.5 13.3 6.5 83 7 84 165 7.1 0 7.3 7 10/12/2006 23:40:00 10.1 1 13.7 6.8 10.2 1.1 13.7 6.8 9.6 1.2 13.3 6.5 111 13 114 165 6.6 0.4 7.3 6 10/12/2006 23:50:00 10.1 0.7 11.8 7.2 10.3 0.7 12.2 7.2 9.3 0.9 11.5 6.5 101 5 107 165 6.1 0 6.2 5.7 10/13/2006 00:00:00 9.2 0.6 10.3 5.7 9.3 0.7 10.3 6.1 8.4 1 10.3 5.3 98 5 99 165 6.2 0 6.2 5.7 10/13/2006 00:10:00 8.8 0.6 10.3 6.1 9 0.6 10.7 5.7 8.5 0.8 9.9 5.7 93 5 99 165 6.3 0 6.5 6.2 10/13/2006 00:20:00 8.7 0.5 9.9 6.1 8.8 0.6 9.9 6.5 8.2 0.7 9.9 5.7 93 3 97 165 6.3 0 6.5 6 10/13/2006 00:30:00 8.9 0.7 10.3 6.5 9.1 0.8 10.3 6.5 8.4 0.9 9.9 5.7 92 5 90 165 6.4 0 6.7 6.2 10/13/2006 00:40:00 8.6 0.8 10.7 5.7 8.8 0.9 10.3 6.1 8.2 0.9 9.9 5.7 96 5 97 165 6.4 0 6.7 6.2 10/13/2006 00:50:00 8.5 0.8 9.9 6.5 8.7 0.8 10.3 6.1 8 0.8 9.9 5.7 94 5 96 165 6.4 0 6.7 6 10/13/2006 01:00:00 8.1 0.7 9.5 6.1 8.2 0.8 9.9 6.1 7.8 0.7 9.5 6.1 90 6 87 165 6.4 0 6.7 6 10/13/2006 01:10:00 7.3 0.8 9.5 4.9 7.4 0.8 9.5 5.3 7.2 0.9 9.5 4.9 88 7 90 165 6.4 0 6.7 6 10/13/2006 01:20:00 8.4 0.9 10.3 6.1 8.6 1 10.7 6.1 8.1 0.9 10.3 5.3 84 6 78 165 6.4 0 6.7 6 10/13/2006 01:30:00 8.9 1 11.1 6.1 9.1 1.1 11.8 6.1 8.5 1 11.1 5.3 93 9 91 165 6.3 0.1 6.5 5.7 10/13/2006 01:40:00 8.2 1 10.3 5.3 8.4 1 10.7 5.3 7.8 1 10.7 5.3 94 7 97 165 6.3 0.1 6.5 5.7 10/13/2006 01:50:00 8.4 1.2 11.1 4.9 8.5 1.3 11.5 4.9 8.1 1.2 11.8 5.3 91 7 89 165 6.2 0.1 6.2 5.7 10/13/2006 02:00:00 9 0.8 10.7 6.5 9.1 0.9 11.1 6.8 8.5 0.9 11.1 6.1 89 6 83 165 6.2 0 6.2 5.7 10/13/2006 02:10:00 7.6 1.1 10.7 4.9 7.7 1.1 10.7 4.9 7.5 1 10.3 4.9 85 7 84 165 6.3 0.1 6.5 5.7 10/13/2006 02:20:00 8.3 0.8 10.3 6.1 8.4 0.9 10.7 6.1 7.8 0.8 9.5 5.3 92 8 89 165 6.3 0 6.5 6 10/13/2006 02:30:00 8.2 1.2 11.1 4.6 8.3 1.3 11.1 4.6 7.8 1.2 11.1 4.6 90 8 87 165 6.3 0.1 6.7 5.7 10/13/2006 02:40:00 8.3 1 11.1 5.7 8.4 1 11.5 5.7 8.1 0.9 11.1 6.1 87 8 89 165 6.3 0 6.5 5.7 10/13/2006 02:50:00 8.1 1.3 10.7 5.3 8.2 1.3 11.5 5.3 8 1.3 11.5 4.9 78 9 75 165 6.3 0 6.5 6 10/13/2006 03:00:00 7.2 1 9.9 4.2 7.3 1.1 9.9 4.6 6.9 1 9.1 4.2 76 9 76 165 6.3 0 6.7 6.2 10/13/2006 03:10:00 6.8 1.1 9.5 3.4 6.9 1.2 9.9 3.8 6.8 1.1 9.1 4.2 80 10 98 165 6.3 0 6.7 6.2 10/13/2006 03:20:00 6 1.1 9.5 3.8 6.1 1.2 9.9 3.8 6 1 9.1 4.2 74 10 73 165 6.2 0 6.5 6.2 10/13/2006 03:30:00 5.7 1 8.4 3.4 5.8 1 8.4 3.4 5.8 0.9 8.4 3.8 70 11 92 165 6.2 0 6.2 6 10/13/2006 03:40:00 6.6 1.3 9.9 3.8 6.7 1.3 9.9 3.8 6.5 1.3 9.9 4.2 62 8 70 165 6.2 0 6.2 6 10/13/2006 03:50:00 6.3 1.1 8.8 3 6.3 1.1 8.8 3 5.9 1 8.4 3 60 11 73 165 6.2 0 6.2 6 10/13/2006 04:00:00 6.7 1.3 9.9 3.4 6.7 1.3 9.9 3.4 6.4 1 9.1 3.8 58 11 59 165 6.2 0 6.2 6 10/13/2006 04:10:00 5.4 1.1 8.4 2.6 5.4 1.1 8.4 3 5.4 1 8 3.4 63 15 44 165 6.2 0 6.2 6 10/13/2006 04:20:00 7.3 1.2 10.3 4.2 7.3 1.3 10.3 3.8 7 1.2 9.9 3.8 75 10 88 165 6.1 0 6.2 5.7 10/13/2006 04:30:00 7.1 1.2 10.3 4.6 7.2 1.3 10.3 4.2 7 1.1 10.3 4.2 73 9 68 165 6.1 0 6.2 6 10/13/2006 04:40:00 6.1 1 9.1 3.8 6.2 1 9.1 3.8 6.1 1 9.1 3.8 72 9 78 165 6.1 0 6.2 6 10/13/2006 04:50:00 7.2 1.5 10.7 3.8 7.3 1.6 11.1 3.8 7 1.5 9.9 3.8 73 12 74 165 6.1 0 6.2 6 10/13/2006 05:00:00 6.3 1 8.8 3.8 6.4 1.1 9.1 3.4 6.3 1 8.8 3.4 69 12 81 165 6.1 0 6.2 5.7 10/13/2006 05:10:00 6.9 1.2 9.9 4.6 7 1.2 10.3 4.6 6.7 1.1 10.3 4.2 62 9 65 165 6.1 0 6.2 5.7 10/13/2006 05:20:00 7.5 1 9.9 5.3 7.5 1.1 9.9 5.3 7.3 1 9.9 4.9 67 7 67 165 6.1 0 6.2 5.7 10/13/2006 05:30:00 7.3 1 9.9 4.9 7.4 1 10.3 4.9 7.2 1 9.5 4.9 65 9 74 165 6.1 0 6.2 5.7 10/13/2006 05:40:00 7 1.3 10.3 3.8 7.1 1.4 10.3 3.8 6.9 1.2 9.5 4.2 63 9 57 165 6.1 0 6.2 5.7 10/13/2006 05:50:00 7.4 1.1 10.3 4.9 7.5 1.2 10.7 4.9 7.2 1 9.9 4.6 63 8 53 165 6.1 0 6.2 5.7 10/13/2006 06:00:00 7.9 1.3 10.7 5.3 7.9 1.4 11.1 4.9 7.6 1.2 10.7 5.3 60 9 60 165 6 0 6.2 5.7 10/13/2006 06:10:00 7.3 1.5 11.5 3.8 7.3 1.5 11.5 3.8 7.1 1.3 10.3 3.4 55 9 51 165 6 0 6.2 5.5 10/13/2006 06:20:00 6.9 1.2 9.5 3.8 6.9 1.2 9.9 4.2 6.8 1 9.9 4.2 55 9 41 165 6.1 0 6.2 5.7 10/13/2006 06:30:00 5.7 1.3 8.8 3 5.6 1.4 8.8 2.6 5.5 1.3 9.1 3 49 12 27 165 6.1 0 6.2 5.7 10/13/2006 06:40:00 6.3 1.5 11.1 3.4 6.3 1.6 11.5 3.4 6.2 1.5 11.5 3 51 13 39 165 6.1 0 6.2 5.5 10/13/2006 06:50:00 5.8 1.1 9.5 2.6 5.7 1.1 9.1 2.6 5.8 1.1 8.8 3.4 49 11 46 165 6.1 0 6.2 5.5 10/13/2006 07:00:00 6.5 1.3 9.9 3 6.5 1.4 9.9 2.6 6.3 1.2 8.8 3 50 11 59 165 6.1 0 6.7 5.7 10/13/2006 07:10:00 5.8 1.1 8.8 2.6 5.8 1.1 9.1 2.6 5.6 1 8.8 3 51 10 69 165 6.1 0 6.2 6 10/13/2006 07:20:00 6 1 8 3 5.9 1 8 3.4 5.8 1 8.4 3.4 48 10 46 165 6.1 0 6.2 6 10/13/2006 07:30:00 6.2 1.2 8.8 3 6.1 1.2 9.1 2.6 6.1 1.2 8.8 3.4 43 9 51 165 6.1 0 6.2 6 10/13/2006 07:40:00 7.1 1 9.5 4.6 7.1 1 9.1 4.2 7.1 0.9 9.5 4.9 40 9 56 165 6.1 0 6.2 6 10/13/2006 07:50:00 8 0.9 10.3 5.7 7.9 1 10.3 5.7 7.7 1 10.3 4.9 37 8 41 165 6.1 0 6.2 6 10/13/2006 08:00:00 8 1.1 10.7 5.3 7.9 1.2 10.7 4.9 7.7 1.1 10.7 5.3 42 7 50 165 6.1 0 6.7 6 10/13/2006 08:10:00 7.2 1.1 10.3 4.6 7.2 1.2 10.7 4.6 6.9 1.1 10.3 4.2 39 8 35 165 6.2 0 6.2 6 10/13/2006 08:20:00 8 1.6 11.1 4.2 8 1.7 11.1 3.8 7.8 1.7 11.1 3.8 34 7 32 165 6.3 0 6.5 6.2 10/13/2006 08:30:00 7.4 1 9.5 3.8 7.4 1 9.5 3.8 7.5 1 9.9 4.2 37 7 43 165 6.4 0 6.7 6.2 10/13/2006 08:40:00 7.1 1.1 9.5 4.6 6.9 1.2 9.5 3.4 6.9 1 9.5 3.8 28 11 31 165 6.4 0 6.7 6.2 10/13/2006 08:50:00 7.7 1.2 9.9 4.6 7.3 1.2 9.9 4.2 7.4 1.1 10.3 4.6 20 7 23 165 6.4 0 6.7 6.2 10/13/2006 09:00:00 6.2 0.9 9.5 4.2 5.7 1 9.1 3 6.2 1 9.5 4.2 19 9 34 165 6.4 0 6.7 6.2 10/13/2006 09:10:00 6.3 1.3 9.5 2.6 6.1 1.4 9.5 1.9 6.2 1.3 9.5 3.4 31 11 19 165 6.5 0 6.7 6.2 10/13/2006 09:20:00 6 1 8.8 3.4 5.4 1.1 9.1 3 5.9 1.2 9.5 3.4 19 9 20 165 6.4 0 6.7 6.2 10/13/2006 09:30:00 6.3 1 8.8 4.2 5.6 1.1 8.4 3 6.2 1 8.8 4.2 17 8 22 165 6.4 0 6.7 6 10/13/2006 09:40:00 6.7 1 10.3 4.2 5.9 1.1 9.1 2.6 6.5 1 10.7 4.6 15 8 10 165 6.4 0 6.7 6 10/13/2006 09:50:00 7.4 1.1 10.3 4.9 6.3 1.3 9.1 3.4 7.2 1.1 9.9 4.6 12 8 32 165 6.4 0 6.7 6 10/13/2006 10:00:00 6.6 0.8 8.4 4.6 5.9 1 8 2.6 6.5 0.8 8.4 4.6 15 8 19 165 6.5 0 6.7 6 10/13/2006 10:10:00 7.1 1 9.1 4.2 5.8 1.1 9.1 3.4 6.9 1 9.5 3.8 10 8 13 165 6.6 0 6.7 6.2 10/13/2006 10:20:00 7 1 9.5 4.6 5.8 1 8 3.4 6.9 1.1 9.5 4.6 11 9 1 165 6.6 0 6.7 6.2 10/13/2006 10:30:00 8.6 1.2 11.5 4.6 7.1 1.4 10.3 3 8.5 1.3 11.1 5.3 10 8 4 165 6.5 0 6.7 6.2 10/13/2006 10:40:00 7.8 1 9.9 5.3 6.7 1.1 9.1 3.8 7.7 1 9.9 5.3 13 8 13 165 6.6 0 6.7 6.2 10/13/2006 10:50:00 7.7 1 10.3 4.6 6.8 1.2 9.5 3.8 7.5 0.9 9.5 5.3 14 7 12 165 6.7 0 7 6.2 10/13/2006 11:00:00 7.3 1 9.9 4.9 6.3 1.2 8.8 3.4 7.1 1 9.5 4.6 13 8 12 165 6.8 0 7.3 6.5 10/13/2006 11:10:00 7.9 1.1 10.7 5.3 7.1 1.2 9.5 3 7.7 1.1 10.3 4.9 15 9 3 165 6.9 0.1 7.3 6.2 10/13/2006 11:20:00 7.2 1.2 9.5 4.9 6.8 1.3 9.5 3 7.1 1.2 9.9 4.2 20 9 15 165 7 0 7.3 6.5 10/13/2006 11:30:00 6.7 1.2 9.5 3.8 6.3 1.2 9.1 3.4 6.6 1 9.5 3.8 22 11 31 165 7 0 7.3 6.5 10/13/2006 11:40:00 7.5 1.2 10.3 4.6 6.8 1.3 10.3 3 7.3 1.2 9.9 4.2 16 8 17 165 7 0 7.3 6.5 10/13/2006 11:50:00 7.6 1 9.5 4.9 7 1.1 9.1 2.6 7.4 1 9.9 4.9 17 8 15 165 7.1 0 7.3 6.7 10/13/2006 12:00:00 7.6 0.9 9.9 4.9 7 1.1 9.1 4.2 7.3 0.9 9.1 4.9 18 7 16 165 7.3 0.1 7.5 6.7 10/13/2006 12:10:00 7.9 0.8 9.5 5.7 7.3 1 9.5 4.2 7.7 0.9 9.9 5.3 18 8 16 165 7.3 0.1 7.5 7 10/13/2006 12:20:00 8 0.9 10.3 5.3 7.6 1.1 10.3 4.6 7.6 1 9.5 4.6 22 7 27 165 7.3 0 7.5 7 10/13/2006 12:30:00 7.2 0.8 9.1 4.6 7 1 9.1 4.2 7.2 1 9.5 4.9 23 7 31 165 7.6 0 7.8 7.3 10/13/2006 12:40:00 6.7 1.1 9.1 4.6 6.5 1.2 9.1 3.8 6.6 1.1 9.5 3.4 28 8 19 165 7.7 0 8 7.3 10/13/2006 12:50:00 7.5 1 9.5 4.2 7.2 1.1 9.1 4.2 7.3 1 9.5 4.6 24 7 32 165 7.8 0.2 8.3 7.3 10/13/2006 13:00:00 7.8 0.8 9.9 4.9 7.5 1 9.5 4.2 7.4 1 9.5 4.9 24 7 20 165 8 0.1 8.3 7.3 10/13/2006 13:10:00 7.8 0.8 9.9 5.3 7.5 1 9.9 4.6 7.5 0.9 9.5 4.9 23 6 32 165 7.7 0.2 8.3 7 10/13/2006 13:20:00 7.6 0.7 8.8 5.3 7.4 0.8 8.8 5.3 7.4 0.8 9.1 4.9 24 6 29 165 7.4 0.1 7.8 7 10/13/2006 13:30:00 7.8 0.6 9.1 5.7 7.5 0.8 9.1 5.7 7.6 0.7 9.1 5.7 22 6 18 165 7.7 0.2 8 7 10/13/2006 13:40:00 8 0.7 9.1 6.1 7.8 0.8 9.1 5.3 7.6 0.8 9.5 5.7 24 6 35 165 7.9 0 8.3 7.5 10/13/2006 13:50:00 7.7 0.7 9.1 5.3 7.4 0.9 9.1 4.6 7.6 0.8 9.9 5.3 23 6 25 165 7.9 0.1 8.3 7.5 10/13/2006 14:00:00 8.1 0.8 9.5 4.9 7.5 1.1 9.1 4.2 7.9 0.9 9.9 5.3 18 6 25 165 8.1 0 8.5 7.8 10/13/2006 14:10:00 8 0.7 9.5 5.3 7.4 1 9.1 4.2 7.9 0.7 9.5 5.7 17 6 19 165 8 0 8.3 7.8 10/13/2006 14:20:00 7.6 0.9 9.1 5.3 7 1.1 9.1 3.4 7.6 0.9 9.5 4.9 18 5 19 165 7.8 0 8 7.5 10/13/2006 14:30:00 7.4 0.6 8.8 5.7 6.9 0.7 8.4 3.8 7.2 0.7 8.8 5.3 19 5 15 165 7.6 0.1 7.8 7.5 10/13/2006 14:40:00 7.2 0.6 8.4 5.3 6.7 0.8 8.4 4.2 7.2 0.7 8.8 4.9 19 6 25 165 7.4 0 7.8 7.3 10/13/2006 14:50:00 7 0.5 8.4 5.3 6.4 0.7 8 3.8 6.9 0.5 8 4.9 17 4 23 165 7.3 0.1 7.5 7 10/13/2006 15:00:00 7.5 0.6 9.9 6.1 6.2 1.2 8.8 3 7.5 0.6 9.9 5.3 14 5 15 165 7.2 0.2 7.5 6.7 10/13/2006 15:10:00 6.9 0.6 9.1 5.7 5.4 1.1 8.4 3 6.9 0.6 8.8 5.3 12 5 16 165 7.3 0.1 7.5 7 10/13/2006 15:20:00 6.4 0.6 8 4.6 5 1.1 7.2 2.6 6.4 0.6 8 4.9 13 5 19 165 7.3 0.2 7.5 7 10/13/2006 15:30:00 6.8 0.6 8.4 5.3 5 1.1 7.2 2.3 6.9 0.6 8.4 5.3 10 6 5 165 7.5 0.1 7.8 7.3 10/13/2006 15:40:00 6.2 0.7 8 4.2 5 1.1 7.6 2.6 6.3 0.7 8.4 4.6 12 7 36 165 7.4 0.1 7.8 7 10/13/2006 15:50:00 6.3 0.6 8 4.6 4.8 1.2 7.2 2.3 6.4 0.6 8.4 4.9 11 7 10 165 7.5 0.1 7.8 7.3 10/13/2006 16:00:00 7.2 0.8 9.1 5.3 5.6 1.2 8.4 2.6 7.1 0.8 8.8 4.9 355 10 7 165 7.4 0.1 7.8 7.3 10/13/2006 16:10:00 7.7 0.9 9.9 4.9 4.8 1 8.4 2.6 7.7 1 10.3 5.7 1 6 357 165 7.4 0.1 7.8 7.3 10/13/2006 16:20:00 7.8 0.8 10.7 5.7 5.7 1.3 9.1 3.4 7.6 0.8 9.9 4.9 0 9 358 165 7.9 0.3 8.3 7.3 10/13/2006 16:30:00 7.4 0.9 9.5 5.7 5.3 1.1 8.8 2.6 7.1 0.8 9.5 4.9 6 8 12 165 7.9 0 8.3 7.5 10/13/2006 16:40:00 6.5 1 9.1 4.6 4.6 1.2 8.8 2.3 6.4 1 9.1 4.6 2 8 4 165 7.6 0.1 7.8 7.3 10/13/2006 16:50:00 6.9 1 8.8 4.2 4.9 1.6 9.1 2.3 6.8 0.9 8.8 4.6 358 7 354 165 7.4 0.1 7.8 7 10/13/2006 17:00:00 6.3 0.8 7.6 4.2 4.6 1.2 8 2.3 6.1 0.8 8 3.8 357 9 359 165 7.4 0.3 7.8 7 10/13/2006 17:10:00 7.1 1 9.5 4.9 5.2 1.3 9.1 2.6 6.9 1 9.5 4.6 355 7 358 165 7.4 0.1 7.8 7 10/13/2006 17:20:00 7.2 0.9 9.9 4.9 5.6 1.2 8.4 3.4 7 1 9.5 4.6 355 7 5 165 7.4 0 7.5 7.3 10/13/2006 17:30:00 6.7 0.8 9.9 4.9 5.2 1.2 9.1 2.6 6.6 0.9 10.7 4.6 356 8 9 165 7.3 0 7.5 7 10/13/2006 17:40:00 7.4 0.9 11.1 4.6 6.9 1 11.5 4.2 7.3 0.8 9.5 5.3 343 17 344 165 7.4 0 7.5 7 10/13/2006 17:50:00 7 1.3 10.7 4.6 5.6 1.6 9.9 2.3 6.9 1.2 10.3 4.9 353 10 357 165 7.4 0 7.5 7.3 10/13/2006 18:00:00 6.6 0.9 9.5 4.6 5 1.2 8 2.6 6.5 1 9.1 3.8 358 11 4 165 7.3 0 7.5 7 10/13/2006 18:10:00 5.5 0.8 7.6 3.4 4.3 1 6.5 1.9 5.5 0.8 7.2 3.8 351 8 354 165 7.1 0 7.3 6.5 10/13/2006 18:20:00 6.2 1 8.4 3.8 5.7 1.3 8.4 1.9 6 0.9 8 3 342 15 7 165 7.1 0 7.3 6.7 10/13/2006 18:30:00 8.2 0.9 11.1 5.7 8 1 11.8 5.3 7.8 0.9 11.1 4.6 327 9 308 165 7.3 0 7.5 6.7 10/13/2006 18:40:00 8.4 1.1 11.5 5.3 8.1 1.3 11.1 3.8 8 1 11.1 4.9 336 12 325 165 7.2 0.2 7.5 6.7 10/13/2006 18:50:00 8.7 1.1 10.7 5.3 8.4 1.5 11.5 4.2 8.1 1.2 10.3 4.6 342 11 343 165 7.1 0.1 7.3 6.5 10/13/2006 19:00:00 7.8 1 10.3 4.9 7.4 1.2 10.3 4.2 7.4 0.9 9.5 4.9 346 7 355 165 6.9 0.2 7.3 6.2 10/13/2006 19:10:00 6.4 1 9.1 4.2 6.1 1.1 9.1 3.4 6.1 1 9.1 3 338 10 331 165 6.7 0.1 7 6 10/13/2006 19:20:00 7.3 1.2 10.7 4.2 7 1.4 11.1 3.4 7.1 1.3 9.9 3.4 341 10 349 165 6.7 0 7 6 10/13/2006 19:30:00 7.6 1.1 10.3 4.9 7.3 1.2 10.3 3.8 7.3 1 9.5 4.9 339 11 343 165 6.8 0 7 6.2 10/13/2006 19:40:00 8.7 1.2 11.8 4.6 8.4 1.4 11.8 4.2 8.3 1.3 11.8 4.2 342 9 358 165 6.8 0 7 6.7 10/13/2006 19:50:00 7.8 1.5 11.5 4.6 7.4 1.5 11.8 4.2 7.1 1.3 10.3 4.2 345 11 351 165 6.8 0 7 6.7 10/13/2006 20:00:00 7.1 1.3 10.7 3.4 6.3 1.3 9.5 3 6.6 1.2 9.9 3.8 347 11 358 165 6.9 0 7.3 6.7 10/13/2006 20:10:00 8.1 1.3 11.8 4.9 7.3 1.4 11.8 3.4 7.4 1.3 10.7 4.6 347 9 350 165 7.1 0 7.3 6.7 10/13/2006 20:20:00 7.4 1.2 10.3 4.9 6.8 1.5 10.3 2.6 6.9 1.2 9.9 3.4 346 9 347 165 6.9 0.1 7.3 6.5 10/13/2006 20:30:00 6.6 1.1 9.1 3 6 1.3 9.1 2.3 5.8 1.2 8.8 2.6 344 13 321 165 6.7 0 7 6.2 10/13/2006 20:40:00 6.7 1.5 10.7 3 6.3 1.5 10.3 2.6 5.9 1.5 10.3 1.9 337 13 358 165 6.6 0 6.7 6 10/13/2006 20:50:00 7.5 1.7 12.2 3.4 7.2 1.7 11.5 2.6 6.7 1.7 11.1 2.3 340 12 351 165 6.4 0 6.7 6 10/13/2006 21:00:00 8 1.5 12.2 4.9 7.8 1.5 13 4.9 7.3 1.3 11.5 4.6 335 10 350 165 6.5 0 6.7 6.2 10/13/2006 21:10:00 8.4 1.3 12.2 4.6 8.1 1.5 12.6 4.2 8 1.3 12.2 4.9 342 10 358 165 6.6 0 6.7 6.2 10/13/2006 21:20:00 9.3 1.5 13 5.3 9.3 1.6 13.3 5.3 9.3 1.6 13.3 5.3 334 9 337 165 6.7 0.1 7 6.2 10/13/2006 21:30:00 8.2 1.3 11.5 5.3 8.1 1.3 11.5 4.9 8 1.4 11.5 4.2 331 12 344 165 6.7 0 7 6.7 10/13/2006 21:40:00 10.8 1.7 15.3 6.1 10.6 1.8 16.1 4.6 10.2 1.6 13.3 6.5 337 10 337 165 6.6 0 7 6.2 10/13/2006 21:50:00 11.6 1.8 17.2 6.8 11.5 1.7 17.6 7.2 11.3 1.9 17.6 6.8 337 11 350 165 6.7 0 7 6.5 10/13/2006 22:00:00 11.6 1.7 16.4 6.5 11.4 1.7 17.2 6.8 11.2 1.7 15.3 7.2 335 10 358 165 6.7 0 7 6.7 10/13/2006 22:10:00 11 2.1 16.8 6.1 10.7 2.1 17.2 5.7 10.6 2.3 16.1 5.3 333 14 351 165 6.8 0 7 6.5 10/13/2006 22:20:00 12 1.5 16.4 7.6 11.8 1.5 16.1 8 11.5 1.5 15.6 7.6 334 9 343 165 6.7 0 7 6.7 10/13/2006 22:30:00 11 1.9 15.3 6.8 10.8 2 15.6 6.5 10.4 1.9 15.6 6.5 335 10 340 165 6.7 0 7 6.5 10/13/2006 22:40:00 11.3 1.7 15.6 6.5 11.1 1.7 15.3 6.5 10.5 1.6 14.1 6.5 335 9 338 165 6.7 0 7 6.5 10/13/2006 22:50:00 11.4 1.7 16.8 7.2 11.2 1.7 16.8 7.2 10.7 1.7 16.1 6.5 333 9 329 165 6.7 0.1 7 6.5 10/13/2006 23:00:00 12 1.8 17.6 7.6 11.8 1.9 17.2 7.6 11.6 2.1 17.2 7.2 336 9 325 165 6.9 0 7.3 6.7 10/13/2006 23:10:00 12.8 1.4 16.4 9.1 12.5 1.3 16.1 9.1 12.1 1.5 17.2 8.4 331 9 336 165 7 0 7.3 6.5 10/13/2006 23:20:00 13.9 1.5 17.2 9.5 13.7 1.5 16.8 8.8 13.1 1.5 16.4 8 336 7 342 165 6.9 0 7 6.2 10/13/2006 23:30:00 13.3 1.8 16.8 8.8 13 2 17.6 8.4 12.5 1.9 15.6 7.2 338 9 334 165 7.1 0 7.3 6.7 10/13/2006 23:40:00 11.8 2.1 17.2 6.8 11.5 2.1 17.9 6.8 11.3 2 16.1 5.7 337 9 345 165 6.9 0.1 7.3 6.2 10/13/2006 23:50:00 11.8 1.7 17.2 8.4 11.7 1.7 17.2 8.4 11.6 1.7 17.9 8 338 10 346 165 7.1 0 7.5 6.7 10/14/2006 00:00:00 10.2 1.5 14.1 4.6 10 1.5 13.7 4.2 9.4 1.5 13 5.3 326 15 330 165 7.2 0 7.5 6.7 10/14/2006 00:10:00 10.4 1.5 14.5 6.8 10.3 1.4 14.1 6.1 9.5 1.3 13.3 6.1 321 10 319 165 6.8 0.2 7.3 6.2 10/14/2006 00:20:00 12.9 2.3 17.2 5.3 12.7 2.2 17.2 4.6 10.7 1.9 14.9 3.8 308 8 299 165 6.6 0 7 6.2 10/14/2006 00:30:00 15.3 1.3 19.1 11.5 15 1.3 18.7 10.7 12.6 1.5 17.2 8.8 308 6 296 165 6.9 0.1 7.3 6.2 10/14/2006 00:40:00 14.3 1.7 20.6 10.7 14.1 1.7 20.6 10.7 12.2 2.2 19.1 7.6 309 9 312 165 7.1 0.1 7.5 6.5 10/14/2006 00:50:00 13 1.5 18.3 8.8 12.7 1.4 18.7 8.8 11.9 1.6 17.2 7.2 321 13 343 165 6.7 0.1 7.3 6 10/14/2006 01:00:00 12.1 1.3 15.6 8.4 11.8 1.3 15.3 8.4 11.1 1.2 14.9 8 322 12 349 165 6.8 0.1 7.5 6.2 10/14/2006 01:10:00 12.9 2.1 17.6 8 12.5 2.1 18.3 7.6 12.3 2 17.9 6.5 334 13 343 165 7.3 0.2 7.8 6.5 10/14/2006 01:20:00 14.4 2 19.5 9.1 14.3 2.1 19.9 8.8 14 2 19.1 9.9 340 9 342 165 7.9 0.1 8.3 7.3 10/14/2006 01:30:00 13.2 1.5 17.9 8 13 1.5 17.2 8.8 11.8 1.7 17.9 7.2 315 12 317 165 7.3 0.4 8 7 10/14/2006 01:40:00 14.3 1.7 18.3 9.9 13.9 1.7 17.9 8.4 12.8 1.7 17.6 8.8 320 15 328 165 7 0.1 7.5 6.7 10/14/2006 01:50:00 13.9 1.3 18.3 9.9 13.7 1.3 18.3 9.9 12.6 1.7 16.4 8 322 13 348 165 7.5 0.1 8 7.3 10/14/2006 02:00:00 14.6 1.7 19.1 10.3 14.3 1.8 18.7 9.5 12.9 1.8 16.8 8 316 9 306 165 7.2 0 7.5 7 10/14/2006 02:10:00 16.6 1.5 20.6 12.6 16.4 1.5 20.6 11.8 14.6 1.7 19.5 9.9 311 7 316 165 7 0.1 7.3 6.7 10/14/2006 02:20:00 15.9 1.4 19.5 11.1 15.6 1.4 19.1 10.7 13.6 1.7 17.9 8.8 310 6 307 165 6.7 0 7 6.5 10/14/2006 02:30:00 15.7 1.3 19.9 12.6 15.4 1.2 19.9 12.2 13.4 1.5 18.7 8.8 311 6 319 165 6.4 0 6.7 6.2 10/14/2006 02:40:00 14.4 1.7 19.9 8.4 14.2 1.6 19.1 8 12.3 1.6 17.9 8.8 308 7 313 165 6.6 0 6.7 6.2 10/14/2006 02:50:00 11.4 2.1 18.7 5.3 11.3 2 18.3 5.7 9.5 1.5 16.4 5.3 310 12 332 165 6.7 0 7 6.5 10/14/2006 03:00:00 11.2 1.9 14.9 6.5 11 1.9 14.5 4.9 9.1 1.5 13.7 5.3 306 9 297 165 6.9 0.1 7.3 6.7 10/14/2006 03:10:00 11.8 1.5 15.3 8 11.7 1.4 15.3 7.6 9.9 1.3 13.3 7.2 305 8 312 165 7.1 0.1 7.5 6.7 10/14/2006 03:20:00 12.2 1.5 15.6 8.8 12 1.3 15.6 8.4 10.6 1.5 14.9 6.1 311 8 313 165 7.2 0 7.5 7 10/14/2006 03:30:00 13.1 1.7 18.7 7.6 12.9 1.7 18.3 7.6 10.6 1.8 15.6 5.7 307 7 306 165 6.9 0 7.3 6.7 10/14/2006 03:40:00 13.5 2 19.5 7.2 13.4 1.9 20.2 7.6 10.9 2.4 17.2 5.3 308 9 307 165 7.1 0.2 7.5 7 10/14/2006 03:50:00 16 1.7 20.6 12.2 15.7 1.7 20.2 11.8 13.1 1.9 18.7 8.4 307 7 304 165 7.1 0.2 7.5 6.5 10/14/2006 04:00:00 18.1 1.1 21.8 14.9 17.9 1.1 21 14.5 15.6 1.5 19.9 11.5 310 5 298 165 6.9 0 7.3 6.2 10/14/2006 04:10:00 17.7 1.3 21 14.1 17.5 1.3 20.2 14.1 14.5 1.6 19.1 10.3 308 5 307 165 7 0.1 7.3 6.5 10/14/2006 04:20:00 18.3 1.4 21.8 14.5 18.1 1.4 21.4 14.5 16.2 1.7 21 11.1 311 4 307 165 7 0 7.3 6.7 10/14/2006 04:30:00 18.4 1.3 21.8 14.5 18.2 1.3 21.4 14.5 17.1 1.4 21.8 12.6 313 5 316 165 6.9 0.1 7.3 6.5 10/14/2006 04:40:00 16.9 1.4 20.6 13 16.7 1.3 20.6 13 14.6 1.7 18.3 9.9 310 4 312 165 7.2 0 7.5 6.7 10/14/2006 04:50:00 17.7 1.6 21.4 12.6 17.6 1.6 21.4 12.6 14.5 1.5 19.5 10.3 308 4 301 165 7.3 0 7.5 6.7 10/14/2006 05:00:00 16.7 1.5 20.6 13.3 16.6 1.6 20.2 13 14.1 1.7 18.7 9.9 309 5 307 165 7.1 0 7.8 6.7 10/14/2006 05:10:00 14.9 1.6 18.7 9.5 14.8 1.6 18.7 9.9 12 1.7 17.6 6.8 307 6 305 165 7.1 0 7.5 6.7 10/14/2006 05:20:00 13.9 1.9 18.7 6.5 13.7 1.9 18.3 6.8 11.7 1.7 16.4 8 309 7 304 165 7.4 0.1 7.8 7 10/14/2006 05:30:00 12.4 1.8 16.1 8 12.2 1.7 15.6 7.6 10.3 1.7 14.9 5.7 309 8 304 165 7.2 0 7.5 6.7 10/14/2006 05:40:00 15.6 1.9 19.5 8.8 15.4 1.8 19.1 9.1 13.3 2.1 17.9 6.5 308 6 316 165 7.1 0 7.3 6.7 10/14/2006 05:50:00 18.2 1.7 22.1 14.1 17.9 1.7 22.1 13.7 16.5 1.6 20.2 11.8 314 6 307 165 7.6 0.2 8 6.7 10/14/2006 06:00:00 16.3 1.7 22.1 11.5 16.1 1.7 22.6 11.1 14.7 2 20.2 10.3 314 6 312 165 7.9 0.2 8.3 7.5 10/14/2006 06:10:00 17.9 1.7 21 12.6 17.6 1.6 21 11.8 16.4 1.8 19.9 10.3 313 6 313 165 7.4 0 7.5 7.3 10/14/2006 06:20:00 19.1 1.2 22.6 15.3 18.7 1.2 22.1 15.3 18.1 1.4 21.4 13.7 315 5 315 165 7.3 0 7.5 7.3 10/14/2006 06:30:00 20.6 1.2 23.7 17.2 20.3 1.2 23.3 16.8 19.6 1.4 22.6 15.6 314 4 312 165 7.4 0 7.5 7.3 10/14/2006 06:40:00 19.9 1.7 22.9 14.9 19.6 1.7 22.6 14.9 17.8 1.7 21.8 13.3 311 5 311 165 7.4 0 7.8 7.3 10/14/2006 06:50:00 21.6 0.9 24.8 18.7 21.5 0.9 24.4 18.7 18.6 1.7 22.9 13.3 310 3 305 165 7.7 0 7.8 7.5 10/14/2006 07:00:00 20.1 1 22.9 16.1 20 1 22.6 15.6 18.8 1.4 22.1 13 312 3 309 165 7.6 0 8 7.5 10/14/2006 07:10:00 18.3 1 21 15.3 18.1 1 21 14.9 17.1 1.3 20.6 12.6 313 4 310 165 8 0.1 8.3 7.5 10/14/2006 07:20:00 18.6 0.7 20.6 16.4 18.5 0.8 20.6 16.1 16.8 1.2 19.5 13.7 312 3 307 165 8.1 0 8.3 8 10/14/2006 07:30:00 18 0.7 19.9 16.1 17.8 0.7 19.5 15.6 16.2 1.3 20.2 12.6 311 3 311 165 8 0.1 8.3 7.8 10/14/2006 07:40:00 16.3 0.9 19.1 13.3 16.1 0.9 18.7 13 15.5 1.2 18.7 12.6 313 4 313 165 7.9 0 8.3 7.5 10/14/2006 07:50:00 16.5 0.8 19.9 14.1 16.4 0.8 19.5 14.1 14.4 1.4 17.6 10.7 310 4 315 165 7.9 0 8 7.5 10/14/2006 08:00:00 16.7 0.9 19.5 14.1 16.6 0.9 19.1 13.7 13.7 1.5 17.2 10.3 309 3 308 165 7.9 0 8 7.5 10/14/2006 08:10:00 17.2 1 19.5 13.7 17 1.1 19.5 13.7 15 1.3 17.9 10.7 310 4 305 165 8 0.1 8.3 7.3 10/14/2006 08:20:00 17.2 1 19.5 13.7 17 1 19.5 13.7 14.9 1.3 17.6 10.3 310 4 309 165 8 0.2 8.3 7.5 10/14/2006 08:30:00 16.2 0.9 18.3 13.3 16.1 0.9 17.9 13.3 14.3 1.3 16.8 10.7 311 3 313 165 7.9 0.2 8.3 7.3 10/14/2006 08:40:00 15.7 0.8 17.9 12.6 15.6 0.9 17.6 12.2 13.7 1.5 17.2 9.9 310 3 313 165 8.1 0.1 8.5 7.5 10/14/2006 08:50:00 14.4 1 17.2 11.8 14.2 1 17.2 11.5 13.3 1.2 16.8 9.9 312 5 309 165 8 0.1 8.3 7.5 10/14/2006 09:00:00 14.3 0.7 15.6 12.2 14.1 0.7 15.6 12.2 13.3 1.2 15.6 10.3 313 4 314 165 8 0.1 8.3 7.5 10/14/2006 09:10:00 16.3 1 18.7 13.7 16.3 1 18.7 13.3 13.3 1.1 16.1 9.5 308 3 303 165 8 0.1 8.3 7.5 10/14/2006 09:20:00 18.6 1 21.4 15.3 18.5 1.1 21 14.9 14.2 1.5 19.1 11.1 306 3 308 165 8 0.1 8.3 7.5 10/14/2006 09:30:00 17.6 0.8 19.9 14.9 17.5 0.8 19.9 14.9 15.9 1.5 19.1 11.8 310 3 308 165 8 0.1 8.3 7.5 10/14/2006 09:40:00 17.1 0.8 18.7 14.5 16.9 0.8 18.7 14.5 15.3 1.2 18.3 11.8 311 3 313 165 8.1 0.1 8.5 7.8 10/14/2006 09:50:00 17.3 1 19.5 14.5 17.2 1 19.5 14.1 14.2 1.5 18.3 9.9 308 3 307 165 8.3 0.1 8.8 7.8 10/14/2006 10:00:00 16.5 1.2 18.7 11.5 16.5 1.3 18.7 11.1 13.8 1.5 17.6 10.3 308 4 307 165 8.3 0.2 8.5 7.8 10/14/2006 10:10:00 14.1 0.8 16.1 12.2 13.9 0.8 16.1 11.8 13.7 1 16.1 10.7 314 3 315 165 8.5 0.2 8.8 8 10/14/2006 10:20:00 15.5 0.9 17.9 13 15.3 0.9 17.6 12.6 15.2 1 17.9 11.8 317 4 310 165 9 0.2 9.6 8.5 10/14/2006 10:30:00 15.6 1.1 19.1 12.2 15.4 1.1 19.5 12.6 14.5 1.2 17.9 10.7 313 4 303 165 9.6 0.1 9.8 9.3 10/14/2006 10:40:00 18.3 0.8 20.6 16.1 18.1 0.8 20.2 15.6 16.6 1.2 19.1 12.2 311 3 307 165 9.8 0 9.8 9.3 10/14/2006 10:50:00 17.8 1.1 21.4 15.3 17.7 1.2 21.4 14.9 16.8 1.2 19.9 12.6 311 4 301 165 9.8 0 10.1 9.6 10/14/2006 11:00:00 17.2 0.8 19.5 14.9 17 0.8 19.1 14.5 16.8 1.1 19.9 13 314 5 312 165 9.6 0.1 10.1 9.3 10/14/2006 11:10:00 15.9 0.8 17.6 13.3 15.7 0.8 17.6 13 15.7 1.1 18.3 12.6 315 5 312 165 9.9 0 10.3 9.6 10/14/2006 11:20:00 16.4 1.2 19.5 13.3 16.2 1.2 19.1 13.3 15.8 1.5 19.1 11.5 314 6 314 165 10.1 0 10.3 9.6 10/14/2006 11:30:00 18.4 1 20.6 14.9 18.2 1 20.2 15.3 15.5 1.5 19.5 10.7 309 3 312 165 10.3 0.1 10.9 9.6 10/14/2006 11:40:00 18.5 0.8 20.2 14.9 18.3 0.8 20.6 14.9 16 1.3 19.9 12.6 311 3 310 165 10.9 0.1 11.4 10.6 10/14/2006 11:50:00 17.8 1 20.6 14.1 17.6 1 20.6 14.1 16.8 1.3 19.9 11.8 314 5 312 165 11.3 0 11.4 11.1 10/14/2006 12:00:00 17.6 1.3 20.2 13.3 17.3 1.3 20.2 13.3 16.4 1.8 20.6 9.9 313 5 309 165 11.2 0 11.4 11.1 10/14/2006 12:10:00 18.7 1.1 21.4 15.3 18.5 1.1 21 14.9 16.5 1.7 19.9 11.8 310 5 310 165 11.2 0 11.4 11.1 10/14/2006 12:20:00 19 1.1 21.8 15.3 18.9 1.1 21.4 15.3 17.3 1.7 21.8 13 311 3 310 165 11.2 0 11.4 11.1 10/14/2006 12:30:00 17.3 1 19.9 14.5 17.2 1 19.5 14.5 15 1.9 19.1 10.3 309 4 308 165 11.6 0.1 11.9 11.4 10/14/2006 12:40:00 16.7 1.2 19.1 12.6 16.6 1.2 19.5 12.6 13.9 1.8 17.6 9.1 308 3 307 165 11.9 0 12.2 11.7 10/14/2006 12:50:00 15 1.2 17.9 11.5 14.9 1.2 17.6 11.5 12.6 1.4 16.8 9.5 309 5 314 165 12.1 0 12.5 11.9 10/14/2006 13:00:00 15.5 1.5 19.1 11.1 15.4 1.5 19.1 11.1 13.1 1.5 16.4 8.8 309 4 305 165 12.1 0 12.5 11.9 10/14/2006 13:10:00 15.5 1.3 19.1 11.1 15.4 1.3 18.7 11.5 14.5 1.5 18.3 10.3 312 5 307 165 11.8 0 12.2 11.7 10/14/2006 13:20:00 16.5 1.4 20.2 11.8 16.4 1.4 19.9 11.5 13.4 1.5 17.2 9.9 307 5 304 165 11.5 0.1 11.9 11.4 10/14/2006 13:30:00 16.6 1.3 19.5 13 16.6 1.3 19.1 12.6 13.6 1.5 19.9 9.9 308 5 314 165 11.1 0 11.4 10.9 10/14/2006 13:40:00 14.9 1 17.2 12.2 14.8 1 17.6 11.8 12 1.6 16.4 8 307 5 302 165 11.1 0 11.4 10.9 10/14/2006 13:50:00 14.1 0.8 17.2 11.1 14.1 0.9 17.2 11.1 10.7 1.3 14.9 7.2 304 4 305 165 11.1 0 11.1 11.1 10/14/2006 14:00:00 13.8 0.7 15.6 11.8 13.7 0.8 15.3 11.5 11.4 1.3 14.1 8 308 4 305 165 11.1 0 11.4 11.1 10/14/2006 14:10:00 13.3 0.9 16.1 10.3 13.2 0.9 16.1 10.7 10.6 1.4 14.1 7.6 306 5 301 165 11.2 0 11.4 11.1 10/14/2006 14:20:00 14 0.9 16.1 11.8 13.9 0.9 16.1 11.8 12.4 1.4 15.3 8.4 309 5 307 165 11.2 0 11.4 11.1 10/14/2006 14:30:00 14.3 1 16.8 11.8 14.1 1 16.8 11.8 12.6 1.7 16.1 8 310 5 310 165 11.2 0 11.4 11.1 10/14/2006 14:40:00 16 0.9 17.9 13.3 15.9 0.9 17.9 13 12.4 1.4 16.4 8.8 306 4 303 165 11.1 0 11.1 10.9 10/14/2006 14:50:00 16.6 1 19.1 13.7 16.6 1 19.5 13.7 13.2 1.7 17.9 9.5 306 4 300 165 11 0 11.1 10.9 10/14/2006 15:00:00 16.5 1.2 19.9 13 16.4 1.3 20.2 13 13 1.9 17.9 9.5 306 5 304 165 10.9 0 11.1 10.9 10/14/2006 15:10:00 15.1 1.7 19.5 9.9 15 1.6 19.9 10.3 12.8 1.7 16.8 8.8 309 6 305 165 10.9 0 11.1 10.9 10/14/2006 15:20:00 14.3 0.9 16.4 11.5 14.3 1 16.4 11.5 11.7 1.6 14.9 8.4 307 4 302 165 10.9 0.2 11.7 10.6 10/14/2006 15:30:00 13.6 0.8 15.3 11.5 13.5 0.8 15.3 11.5 12.3 1.4 15.6 8.4 310 4 303 165 10.9 0 11.1 10.6 10/14/2006 15:40:00 11.2 1.3 14.5 8 11.1 1.3 14.1 7.6 10.8 1.5 13.7 7.6 314 6 310 165 11.2 0 11.4 11.1 10/14/2006 15:50:00 8.3 0.9 9.9 6.1 8.2 0.9 9.9 6.1 8.3 0.8 10.3 6.5 317 6 326 165 11.1 0 11.4 10.9 10/14/2006 16:00:00 8 0.7 9.9 6.5 7.9 0.6 9.9 6.1 8 0.6 9.5 5.7 315 6 323 165 11.1 0 11.4 10.9 10/14/2006 16:10:00 7.9 1.2 11.1 5.7 7.9 1.3 11.5 5.7 7 1.2 10.7 4.9 301 9 318 165 10.7 0.1 11.1 10.6 10/14/2006 16:20:00 6.9 1.2 9.9 4.6 6.9 1.2 10.3 4.6 6.3 1.4 10.7 3.4 304 10 285 165 10.6 0.1 10.9 10.1 10/14/2006 16:30:00 7.5 0.9 10.3 5.3 7.4 0.9 10.3 5.3 7.3 0.9 9.5 3.8 316 11 298 165 10.7 0 10.9 10.1 10/14/2006 16:40:00 7.9 0.8 9.9 6.1 7.7 0.9 9.5 5.3 8.2 0.7 9.9 6.5 338 8 336 165 10.3 0 10.6 10.3 10/14/2006 16:50:00 9 0.8 10.7 7.6 8.9 0.9 11.1 7.2 8.4 1 11.1 6.1 315 10 318 165 10.3 0 10.6 10.1 10/14/2006 17:00:00 8.3 0.7 9.9 6.8 8.2 0.6 9.9 6.5 8.4 0.7 9.9 6.1 317 5 313 165 10 0 10.3 9.8 10/14/2006 17:10:00 7.7 0.6 9.1 6.5 7.6 0.6 8.8 6.1 7.8 0.6 9.5 6.5 322 6 309 165 9.6 0.1 9.8 9 10/14/2006 17:20:00 7.9 0.7 9.9 6.5 7.8 0.7 9.5 6.1 7.7 0.6 9.5 6.1 313 5 308 165 9.8 0.2 10.3 9.3 10/14/2006 17:30:00 7.9 0.8 10.7 6.5 7.8 0.8 10.7 6.5 6.9 1 9.5 4.9 307 5 303 165 9.8 0.2 10.3 9 10/14/2006 17:40:00 8.1 0.6 9.5 6.8 8 0.6 9.5 6.5 7.4 0.8 9.5 4.6 310 6 308 165 9.6 0.1 10.1 9 10/14/2006 17:50:00 8.1 0.5 9.5 6.5 8.1 0.6 9.5 6.1 5.9 0.5 7.6 4.2 300 3 302 165 9.6 0.1 9.8 9 10/14/2006 18:00:00 6.7 0.6 9.1 5.3 6.8 0.6 9.1 5.7 5.8 0.7 7.6 3.8 294 3 293 165 9.6 0.2 9.8 9 10/14/2006 18:10:00 5.6 0.5 6.8 4.6 5.6 0.4 6.8 4.6 4.4 0.5 5.7 3 298 4 295 165 9.6 0 9.6 8.8 10/14/2006 18:20:00 5.8 0.6 6.8 4.6 5.9 0.6 7.2 4.6 4.5 0.6 6.1 3 298 4 298 165 9.5 0.1 9.8 9.3 10/14/2006 18:30:00 6.1 0.4 7.2 4.9 6.1 0.4 7.2 4.9 4.5 0.5 6.5 3.4 297 3 300 165 9.6 0 9.6 9.3 10/14/2006 18:40:00 6.3 0.3 7.2 5.7 6.4 0.3 7.2 5.7 4.7 0.5 6.1 3.8 298 3 307 165 9.4 0 9.6 9.3 10/14/2006 18:50:00 7 0.6 8.4 5.3 7.2 0.5 8.4 5.3 5.5 0.7 7.6 4.2 297 4 299 165 9.4 0 9.6 9 10/14/2006 19:00:00 8 0.5 9.1 6.5 8 0.4 9.1 6.5 6.2 0.6 8 4.6 304 3 303 165 9.6 0 9.6 9.3 10/14/2006 19:10:00 8.4 0.6 9.5 6.8 8.3 0.6 9.5 6.8 6.3 0.8 8.4 4.2 304 3 307 165 9.7 0 9.8 9.6 10/14/2006 19:20:00 8.6 0.6 10.3 6.5 8.5 0.6 10.3 6.5 6.7 0.8 8.8 5.3 305 4 306 165 9.9 0 10.1 9.6 10/14/2006 19:30:00 8.3 0.5 9.5 6.5 8.3 0.5 9.5 6.5 6.5 0.7 8.8 4.9 300 6 294 165 10 0 10.3 9.6 10/14/2006 19:40:00 8.2 0.5 9.5 6.5 8.2 0.5 9.5 6.1 6.6 0.8 8.8 4.2 296 4 300 165 9.8 0 10.1 9.6 10/14/2006 19:50:00 7.5 0.5 9.1 5.7 7.5 0.5 8.8 5.3 5.8 0.6 8 4.6 301 5 297 165 9.8 0 10.1 9.6 10/14/2006 20:00:00 8.4 0.5 9.5 6.8 8.3 0.6 9.5 6.5 6.2 0.6 8.8 4.9 301 4 299 165 9.6 0 9.8 9.3 10/14/2006 20:10:00 7.4 0.8 9.9 5.7 7.4 0.8 9.5 5.7 5.6 0.7 8 4.2 300 4 297 165 9.4 0 9.6 8.8 10/14/2006 20:20:00 5.9 0.6 7.6 4.6 5.9 0.6 7.2 4.6 4.8 0.6 6.5 3 294 5 291 165 9.1 0.1 9.3 8.8 10/14/2006 20:30:00 5.9 0.4 6.8 4.6 6 0.4 6.8 4.6 5.6 0.5 6.8 4.2 286 4 290 165 8.9 0 9 8.5 10/14/2006 20:40:00 5.8 0.5 6.5 4.2 5.9 0.4 6.8 4.6 5.5 0.6 6.8 3.4 287 4 287 165 8.9 0 9.3 8.5 10/14/2006 20:50:00 5.9 0.5 7.6 4.9 6 0.5 7.2 4.6 5.5 0.6 6.8 3.4 286 5 293 165 8.9 0.1 9 8.5 10/14/2006 21:00:00 6.7 0.7 8.4 4.9 6.6 0.6 8 4.9 5.4 0.8 7.2 3.4 292 5 295 165 8.6 0.2 9 8.3 10/14/2006 21:10:00 7.5 0.6 9.1 6.1 7.4 0.6 9.1 6.1 5.7 0.7 7.2 3.8 299 4 298 165 9 0.2 9.6 8.5 10/14/2006 21:20:00 7.8 0.6 9.1 6.1 7.7 0.6 9.1 5.7 6.2 0.8 9.1 3.8 294 4 299 165 9.3 0.1 9.6 9 10/14/2006 21:30:00 6.9 0.8 8.8 4.9 6.8 0.8 8.8 4.6 6.2 0.8 8.4 3.8 289 5 292 165 9.3 0.1 9.6 8.8 10/14/2006 21:40:00 6.5 0.8 8.8 4.2 6.6 0.8 8.8 4.2 6 0.9 8.8 3.8 284 5 282 165 9.2 0.1 9.6 8.8 10/14/2006 21:50:00 6.9 0.7 8.4 4.9 6.8 0.7 8.4 4.9 6.1 0.7 8 3.8 285 6 285 165 9.3 0.2 9.6 9 10/14/2006 22:00:00 6.4 0.9 8.4 3.8 6.5 0.8 8.4 4.2 5.9 0.9 8.4 3.4 280 7 279 165 9.2 0.2 9.6 8.8 10/14/2006 22:10:00 6.6 0.6 8 4.2 6.7 0.6 7.6 4.2 6.4 0.6 8 4.6 281 4 280 165 9.4 0.2 9.6 9 10/14/2006 22:20:00 5.7 0.5 6.8 4.2 5.8 0.5 6.8 4.2 4.9 0.7 6.8 3.4 289 5 291 165 9.2 0.1 9.6 8.8 10/14/2006 22:30:00 6.1 0.7 7.6 4.2 6.2 0.7 7.6 4.6 5.4 0.8 7.2 3.4 287 4 287 165 9.1 0.1 9.6 8.8 10/14/2006 22:40:00 6.9 0.7 8.4 4.6 6.9 0.6 8.4 4.9 6.1 1 8.4 3.4 285 5 282 165 9.4 0.2 9.6 9 10/14/2006 22:50:00 7.7 0.6 8.8 5.7 7.7 0.6 9.1 5.7 6.8 1 8.8 3.8 288 3 287 165 9.5 0.2 9.8 9 10/14/2006 23:00:00 8.6 0.5 9.5 7.2 8.7 0.5 9.5 6.8 7.8 0.8 9.5 5.3 286 3 286 165 9.5 0.3 9.8 9 10/14/2006 23:10:00 8.7 0.7 10.3 6.8 8.6 0.7 10.3 6.5 7.3 1 9.9 4.9 291 5 296 165 9.8 0.2 10.3 9 10/14/2006 23:20:00 9.3 0.6 10.7 7.2 9.3 0.6 10.7 6.8 7.1 0.8 9.1 4.9 295 4 295 165 10.1 0.2 10.3 9.6 10/14/2006 23:30:00 9.7 0.6 11.1 8 9.7 0.7 11.5 8 7.3 0.9 9.9 4.9 295 4 293 165 10.2 0.1 10.6 9.6 10/14/2006 23:40:00 9.4 0.6 10.7 7.2 9.3 0.6 10.7 7.2 6.9 0.8 9.5 4.9 296 4 290 165 10.4 0.1 10.9 10.3 10/14/2006 23:50:00 8.9 0.8 11.5 6.8 8.8 0.9 11.1 6.5 6.6 0.8 9.1 4.9 299 5 298 165 10.6 0.1 10.9 10.3 10/15/2006 00:00:00 9.2 0.6 10.7 7.2 9 0.6 10.7 7.2 7.7 0.9 9.9 5.7 307 5 305 165 10.7 0.1 11.1 10.3 10/15/2006 00:10:00 8.7 0.9 11.1 6.1 8.6 1 10.7 6.1 7.4 0.8 9.9 4.9 308 5 308 165 10.9 0 11.1 10.6 10/15/2006 00:20:00 8.6 0.8 10.7 5.3 8.4 0.8 10.3 5.3 7.7 0.8 9.5 5.3 310 5 306 165 10.9 0 11.1 10.9 10/15/2006 00:30:00 8.3 0.9 10.3 5.7 8.2 0.9 10.3 5.7 7.2 0.7 8.8 5.3 309 7 301 165 10.9 0 11.1 10.6 10/15/2006 00:40:00 8.4 0.6 10.3 7.2 8.4 0.6 9.9 6.8 6.5 0.7 8.8 4.6 302 4 304 165 11.1 0 11.4 10.9 10/15/2006 00:50:00 6.6 0.9 8.4 4.2 6.5 0.8 8.8 4.2 5.2 0.8 7.2 3.4 296 6 302 165 10.9 0.1 11.4 10.6 10/15/2006 01:00:00 5.6 0.8 7.6 3.4 5.6 0.7 7.6 3.4 4.3 0.7 6.5 2.6 296 6 283 165 10.6 0.2 10.9 10.3 10/15/2006 01:10:00 6.9 1 9.1 4.6 6.9 1 9.1 4.2 6 1 8.8 3.4 290 5 293 165 10.5 0.2 10.9 10.3 10/15/2006 01:20:00 8.3 0.5 9.5 6.8 8.3 0.5 9.5 6.8 7.8 0.6 9.5 6.1 290 4 296 165 10.7 0.1 11.1 10.3 10/15/2006 01:30:00 8 0.5 9.9 6.5 8.1 0.5 9.9 6.5 8.2 0.6 9.9 6.1 283 4 292 165 10.8 0.1 11.1 10.6 10/15/2006 01:40:00 7.5 0.6 9.5 6.1 7.6 0.6 9.5 6.5 7.5 0.6 9.1 6.1 288 3 293 165 10.7 0.1 11.1 10.3 10/15/2006 01:50:00 6.2 0.6 7.6 4.6 6.2 0.7 7.6 4.6 5.6 0.9 7.2 3.8 291 5 297 165 10.9 0 11.4 10.6 10/15/2006 02:00:00 6.1 0.4 7.2 4.9 6 0.5 7.2 4.9 5.9 0.7 7.2 3.8 290 6 292 165 10.8 0.2 11.4 10.6 10/15/2006 02:10:00 5.1 0.4 6.5 3.8 5.2 0.4 6.1 4.2 5.5 0.5 6.8 4.6 283 6 285 165 10.3 0.2 10.9 9.8 10/15/2006 02:20:00 4 0.5 5.3 2.3 4 0.6 5.7 2.6 4.3 0.5 5.7 3 277 5 277 165 10.1 0.2 10.9 9.6 10/15/2006 02:30:00 3.6 0.4 4.6 2.6 3.6 0.4 4.6 2.6 3.5 0.5 4.6 2.3 287 7 291 165 10.5 0.2 11.1 9.8 10/15/2006 02:40:00 4 0.4 4.9 2.3 4 0.5 4.9 1.9 4.1 0.6 5.3 2.3 277 4 271 165 10.9 0.1 11.1 10.6 10/15/2006 02:50:00 3.8 0.3 4.6 3 3.9 0.3 4.6 3.4 4.2 0.3 4.9 3.4 277 3 278 165 10.9 0 11.4 10.6 10/15/2006 03:00:00 3.9 0.3 4.6 3 3.9 0.3 4.6 3 4.1 0.3 4.9 3.4 279 3 282 165 11.3 0 11.7 10.9 10/15/2006 03:10:00 3.7 0.3 4.2 3 3.7 0.3 4.6 3 4 0.4 4.9 3 285 3 278 165 11.4 0 11.7 11.1 10/15/2006 03:20:00 2.2 0.6 4.2 1.1 2.5 0.5 4.2 1.5 2.7 0.6 4.2 1.5 265 9 284 165 11.5 0.2 11.9 11.1 10/15/2006 03:30:00 1.8 0.6 3.8 0.4 1.8 0.6 3.8 0.4 1.8 0.6 3.4 0.4 237 14 251 165 10.3 0.4 11.4 9.6 10/15/2006 03:40:00 2.2 0.7 3.8 0.4 2.6 0.9 3.8 0.4 2.8 0.9 4.2 0.7 260 9 255 165 10 0.1 10.3 9.3 10/15/2006 03:50:00 0.9 0.5 1.9 0.4 1.1 0.8 3.4 0.4 1.5 0.9 3.4 0.4 190 61 255 165 9.7 0.2 10.3 9.3 10/15/2006 04:00:00 0.5 0.2 1.5 0.4 0.4 0.2 1.5 0.4 1 0.5 1.9 0.4 154 41 211 165 9.6 0.1 9.8 9 10/15/2006 04:10:00 0.5 0.3 1.5 0.4 0.5 0.2 1.5 0.4 0.9 0.4 1.9 0.4 147 17 130 165 9.2 0 9.6 8.8 10/15/2006 04:20:00 0.8 0.6 2.6 0.4 0.8 0.6 2.6 0.4 0.8 0.5 2.6 0.4 219 47 249 165 9.2 0.1 9.6 8.8 10/15/2006 04:30:00 2.2 0.6 3.8 0.7 2.2 0.6 3.8 0.7 2.5 0.6 4.2 1.5 239 22 216 165 9.8 0.3 10.3 9 10/15/2006 04:40:00 2.4 0.5 3.4 1.1 2.2 0.6 3.4 1.1 2.4 0.4 3.4 1.5 220 9 217 165 9.6 0.2 9.8 9 10/15/2006 04:50:00 2 0.5 3 0.7 1.8 0.6 3 0.4 2.5 0.4 3.4 1.9 213 6 212 165 9.9 0 10.3 9.6 10/15/2006 05:00:00 0.7 0.4 1.9 0.4 0.4 0.2 1.5 0.4 1.4 0.6 2.6 0.4 213 7 221 165 10 0.1 10.3 9.6 10/15/2006 05:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.9 0.3 1.5 0.4 237 32 165 165 10 0.1 10.3 9.6 10/15/2006 05:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.5 0.3 1.5 0.4 320 0 165 165 9.7 0.4 10.3 8.8 10/15/2006 05:30:00 0.7 0.3 1.5 0.4 0.4 0.1 1.1 0.4 1.9 0.4 2.6 0.4 345 15 356 165 8.6 0.3 9 7.8 10/15/2006 05:40:00 0.8 0.8 3 0.4 0.6 0.6 2.6 0.4 1.6 0.8 3.4 0.4 3 16 22 165 8.5 0.2 9 7.8 10/15/2006 05:50:00 3.4 0.3 3.8 2.3 3.1 0.3 3.8 1.9 3.6 0.3 4.2 2.6 26 3 28 165 7.7 0.2 8.5 7.3 10/15/2006 06:00:00 3.5 0.2 3.8 3 3.2 0.3 3.8 2.3 3.9 0.2 4.6 3.4 24 5 26 165 7.3 0 7.5 7.3 10/15/2006 06:10:00 2.6 0.7 3.8 0.7 2.5 0.8 4.2 0.4 3.1 0.6 4.6 1.1 61 17 31 165 7.3 0.1 7.5 7.3 10/15/2006 06:20:00 1.7 0.6 3 0.4 1.4 0.7 3 0.4 2.1 0.5 3.4 0.7 103 36 90 165 7.4 0 7.5 7.3 10/15/2006 06:30:00 1.1 0.6 2.6 0.4 0.8 0.6 2.6 0.4 1.5 0.5 3 0.4 133 13 128 165 7.4 0 7.5 7.3 10/15/2006 06:40:00 1.6 0.5 2.6 0.7 1.4 0.5 2.3 0.4 2 0.4 2.6 1.1 115 9 130 165 7.4 0 7.5 7.3 10/15/2006 06:50:00 1.1 0.4 1.9 0.4 0.7 0.5 1.9 0.4 1.6 0.4 2.3 0.7 119 7 129 165 7.4 0 7.5 7.3 10/15/2006 07:00:00 1.2 0.6 2.3 0.4 0.9 0.6 2.3 0.4 1.6 0.4 2.6 0.7 107 6 102 165 7.4 0 7.8 7.3 10/15/2006 07:10:00 1.3 0.4 2.3 0.4 1 0.5 2.3 0.4 1.6 0.4 2.6 0.7 105 7 119 165 7.4 0 7.8 7.3 10/15/2006 07:20:00 1.4 0.4 2.3 0.4 1 0.5 2.3 0.4 1.9 0.3 2.6 1.1 113 9 118 165 7.5 0 7.8 7.5 10/15/2006 07:30:00 1 0.4 2.3 0.4 0.6 0.4 1.9 0.4 1.6 0.3 2.3 0.7 135 9 126 165 7.7 0 7.8 7.3 10/15/2006 07:40:00 1.5 0.3 2.3 1.1 0.8 0.4 1.5 0.4 2 0.2 2.6 1.5 166 5 164 165 7.4 0.1 7.5 7 10/15/2006 07:50:00 1 0.5 2.3 0.4 0.5 0.3 1.9 0.4 1.7 0.3 2.3 1.1 179 12 164 165 7.2 0 7.5 6.7 10/15/2006 08:00:00 1.2 0.4 2.3 0.4 0.7 0.4 1.9 0.4 1.7 0.3 2.3 0.7 160 6 161 165 7.4 0.1 7.8 7 10/15/2006 08:10:00 1.4 0.4 2.3 0.4 1.1 0.4 1.9 0.4 1.9 0.3 2.6 1.1 134 11 152 165 7.8 0.1 8.3 7.3 10/15/2006 08:20:00 0.4 0.1 1.1 0.4 0.4 0 0.4 0.4 0.7 0.4 1.5 0.4 48 79 124 165 7.8 0 8 7.5 10/15/2006 08:30:00 0.4 0.1 1.1 0.4 0.4 0 0.4 0.4 0.6 0.3 1.5 0.4 187 43 115 165 8 0.2 8.5 7.5 10/15/2006 08:40:00 1.4 1 3.4 0.4 1.3 1 3.4 0.4 1.8 1 3.4 0.4 330 69 285 165 8.1 0.3 8.5 7.5 10/15/2006 08:50:00 0.9 0.7 2.6 0.4 0.8 0.7 3 0.4 1.3 0.9 3.4 0.4 325 49 279 165 8.5 0.2 8.8 8 10/15/2006 09:00:00 0.9 0.5 1.9 0.4 0.8 0.5 1.9 0.4 1.5 0.5 2.6 0.4 326 15 307 165 8.4 0.1 8.8 7.8 10/15/2006 09:10:00 1.9 0.8 3.8 0.4 1.9 0.8 3.8 0.4 2.3 0.6 4.2 0.7 301 10 295 165 8.6 0.1 8.8 8.3 10/15/2006 09:20:00 5.5 1.3 8 2.6 5.6 1.3 8 2.6 4.7 1.2 8 1.9 297 7 288 165 8.8 0 9 8.5 10/15/2006 09:30:00 5.3 0.9 7.6 3.4 5.4 1 8 3.4 4.7 0.7 7.6 3 304 9 298 165 8.7 0 9 8.3 10/15/2006 09:40:00 4 0.8 5.7 2.3 3.9 0.8 5.7 1.9 3.6 0.6 5.3 2.3 308 9 293 165 8.8 0 9.3 8.5 10/15/2006 09:50:00 2.9 1.1 5.7 0.7 2.8 1.2 6.1 0.7 3.2 1.2 7.2 1.1 285 13 282 165 9.6 0.1 9.8 9 10/15/2006 10:00:00 6.5 1 8.8 3.4 6.6 1 8.8 3.4 6 1 8 2.6 293 5 298 165 9 0.1 9.6 8.8 10/15/2006 10:10:00 5.7 0.6 7.6 4.6 6 0.6 7.6 4.6 5.5 0.6 7.6 3.4 285 6 291 165 9 0 9.3 8.8 10/15/2006 10:20:00 5.2 0.4 6.1 3.8 5.4 0.4 6.1 4.2 5.3 0.5 6.5 4.2 281 7 281 165 9.3 0.1 9.6 9 10/15/2006 10:30:00 4.1 0.7 5.3 2.3 4.5 0.5 5.7 3.4 4.4 0.5 5.7 3 274 5 281 165 10 0.2 10.6 9.6 10/15/2006 10:40:00 3.1 0.6 4.9 1.9 3.9 0.5 5.3 2.6 4 0.4 5.3 3 267 5 276 165 10.6 0.1 11.1 10.3 10/15/2006 10:50:00 2.6 0.7 4.2 1.1 3.2 0.6 4.6 1.5 3.4 0.6 4.9 1.9 254 13 244 165 10.9 0.1 11.1 10.6 10/15/2006 11:00:00 3.5 0.7 4.9 0.7 3.6 0.7 4.9 0.4 4 0.6 4.9 1.9 222 15 235 165 10.7 0 11.1 10.9 10/15/2006 11:10:00 3.1 0.9 4.9 0.4 3 1 4.9 0.4 3.5 0.7 4.9 1.5 190 17 242 165 10.9 0 11.1 10.6 10/15/2006 11:20:00 3.3 0.7 4.9 1.5 3.1 0.7 4.6 1.1 3.7 0.6 5.3 2.3 169 7 164 165 10.4 0.2 10.9 10.3 10/15/2006 11:30:00 3.5 0.5 4.6 1.9 3.2 0.5 4.6 1.9 3.6 0.5 4.9 2.3 169 7 176 165 9.6 0.3 10.3 9 10/15/2006 11:40:00 3 0.4 4.2 1.9 2.9 0.5 4.2 1.5 3.2 0.4 4.2 1.9 166 6 168 165 9.3 0 9.8 9 10/15/2006 11:50:00 2.9 0.5 4.2 1.5 2.9 0.5 4.6 1.9 3.2 0.5 4.9 2.3 178 11 168 165 9.6 0 9.8 9.3 10/15/2006 12:00:00 1.9 0.6 3.4 0.7 2 0.6 3.4 0.7 2.4 0.6 3.8 0.7 179 14 168 165 9.7 0 9.8 9.6 10/15/2006 12:10:00 1.9 0.4 3 0.7 1.9 0.4 2.6 0.4 2.3 0.3 3 1.5 174 8 172 165 9.6 0.1 10.3 9.6 10/15/2006 12:20:00 2.5 0.7 4.6 0.7 2.4 0.7 3.8 0.7 2.9 0.6 4.6 1.5 174 12 165 165 10 0.2 10.9 9.3 10/15/2006 12:30:00 3 0.5 4.2 1.5 2.8 0.5 4.2 1.1 3.2 0.5 4.6 2.3 175 9 173 165 10.3 0 10.9 9.8 10/15/2006 12:40:00 3 0.6 4.2 1.1 2.8 0.6 4.2 1.1 3.2 0.5 4.6 1.9 162 8 159 165 9.8 0 10.1 9.6 10/15/2006 12:50:00 2.5 0.6 3.8 1.1 2.1 0.7 3.8 0.4 2.8 0.6 4.6 1.5 166 8 184 165 10.1 0.2 10.6 9.6 10/15/2006 13:00:00 3 0.5 4.2 1.5 2.9 0.5 4.2 1.5 3.3 0.4 4.6 2.3 159 11 166 165 10.3 0 10.6 10.3 10/15/2006 13:10:00 3.2 0.5 4.2 1.9 3.1 0.5 4.2 1.9 3.4 0.4 4.2 2.3 155 9 143 165 10.5 0.3 11.1 10.3 10/15/2006 13:20:00 3.2 0.6 4.6 1.5 3.1 0.6 4.6 1.1 3.4 0.5 4.9 2.3 145 13 165 165 10.7 0 11.1 10.6 10/15/2006 13:30:00 3 0.6 4.6 1.5 3 0.6 4.6 1.5 3.3 0.5 4.6 2.3 135 11 147 165 10.5 0.3 11.1 10.3 10/15/2006 13:40:00 3.4 0.6 4.9 1.9 3.3 0.6 4.9 1.9 3.6 0.6 5.3 2.3 140 13 122 165 10.9 0.1 11.7 10.9 10/15/2006 13:50:00 3.5 0.6 4.9 1.9 3.3 0.7 4.9 1.9 3.8 0.6 5.3 2.3 151 15 128 165 10.9 0.2 11.7 10.3 10/15/2006 14:00:00 2.9 0.5 4.6 1.9 2.7 0.6 4.2 1.5 3.1 0.6 4.9 1.9 130 17 134 165 10.5 0.1 11.1 10.3 10/15/2006 14:10:00 2.8 0.5 4.6 1.5 2.6 0.6 4.6 0.7 3 0.5 4.6 2.3 133 12 144 165 10.7 0.1 11.1 10.6 10/15/2006 14:20:00 3.1 0.6 4.6 1.1 2.9 0.7 4.6 0.7 3.2 0.6 4.9 1.5 140 12 142 165 11 0 11.1 10.9 10/15/2006 14:30:00 2.4 0.5 4.2 1.1 2 0.7 3.8 0.4 2.5 0.5 4.6 1.5 138 14 168 165 10.9 0.1 11.1 10.9 10/15/2006 14:40:00 2.5 0.5 3.8 1.1 2.1 0.6 3.4 0.7 2.7 0.5 3.8 1.5 148 15 147 165 10.8 0.1 11.1 10.6 10/15/2006 14:50:00 1.9 0.4 2.6 0.4 1.4 0.5 2.6 0.4 2.1 0.3 3 1.1 149 10 153 165 10.3 0.1 10.9 9.8 10/15/2006 15:00:00 1.3 0.5 3 0.4 0.7 0.6 2.6 0.4 1.5 0.4 2.6 0.7 133 8 119 165 10.3 0.1 10.9 10.1 10/15/2006 15:10:00 1 0.5 2.6 0.4 0.8 0.5 2.3 0.4 1.3 0.5 2.6 0.4 120 17 98 165 11.2 0.3 11.9 10.6 10/15/2006 15:20:00 0.8 0.5 1.9 0.4 0.6 0.4 1.9 0.4 1.1 0.4 1.9 0.4 54 61 114 165 11.7 0.2 12.2 11.4 10/15/2006 15:30:00 0.7 0.5 2.3 0.4 0.6 0.4 1.9 0.4 1 0.5 2.3 0.4 22 16 14 165 11.9 0.1 12.2 11.7 10/15/2006 15:40:00 0.7 0.4 2.3 0.4 0.5 0.3 2.6 0.4 0.8 0.5 2.3 0.4 34 69 253 165 11.3 0.1 11.9 11.1 10/15/2006 15:50:00 1.1 0.5 2.6 0.4 0.7 0.5 2.3 0.4 1.4 0.4 2.3 0.4 117 15 94 165 11.1 0 11.9 10.9 10/15/2006 16:00:00 1.7 0.8 3 0.4 1.6 0.9 3.4 0.4 2.1 0.8 3.8 0.4 69 30 44 165 10.3 0.6 11.1 9.3 10/15/2006 16:10:00 1.9 0.5 3.4 0.7 2 0.5 3.4 0.7 2.5 0.4 3.8 1.5 52 11 53 165 9 0 9.3 9 10/15/2006 16:20:00 2.6 0.4 3.4 1.5 2.6 0.4 3.4 1.5 2.5 0.5 3.4 1.5 38 8 44 165 9 0 9.3 9 10/15/2006 16:30:00 2 0.3 2.6 1.5 2 0.3 2.6 1.1 2 0.4 2.6 1.1 26 8 39 165 9.2 0 9.6 9 10/15/2006 16:40:00 2 0.3 3 1.1 1.8 0.3 2.6 1.1 2.1 0.3 2.6 1.1 14 9 356 165 9 0 9.3 8.8 10/15/2006 16:50:00 1.8 0.3 2.6 1.1 1.9 0.3 2.6 0.7 2 0.3 2.6 1.1 26 9 20 165 8.6 0.1 8.8 8.3 10/15/2006 17:00:00 0.5 0.2 1.5 0.4 0.8 0.3 1.5 0.4 1.5 0.3 2.3 0.7 33 1 34 165 8.5 0.1 8.8 8 10/15/2006 17:10:00 0.4 0 0.4 0.4 0.4 0.1 1.1 0.4 0.9 0.4 2.3 0.4 63 21 165 165 8.5 0 8.8 8.3 10/15/2006 17:20:00 1.3 0.5 2.3 0.4 1.5 0.6 2.3 0.4 1.7 0.6 2.6 0.4 47 20 23 165 8.4 0 8.5 8.3 10/15/2006 17:30:00 1.7 0.5 2.3 0.4 2 0.5 2.6 0.4 2.2 0.3 2.6 1.1 26 9 23 165 8.1 0.1 8.5 7.8 10/15/2006 17:40:00 1.9 0.3 2.6 1.5 2 0.5 3 0.7 2.3 0.2 2.6 1.9 24 5 23 165 7.7 0.1 8.3 7.3 10/15/2006 17:50:00 0.9 0.6 2.3 0.4 1 0.6 2.3 0.4 1.7 0.6 2.6 0.4 23 43 5 165 7.7 0.2 8 7.3 10/15/2006 18:00:00 1.5 0.6 2.6 0.4 1.7 0.6 2.6 0.4 2.2 0.5 2.6 0.7 17 28 31 165 7.8 0.2 8.3 7.3 10/15/2006 18:10:00 1.2 0.8 2.6 0.4 1.5 0.8 3 0.4 1.9 0.6 3 0.4 41 23 31 165 7.8 0 8 7.5 10/15/2006 18:20:00 0.4 0 0.4 0.4 0.4 0.1 1.1 0.4 0.4 0.1 1.1 0.4 103 17 165 165 8 0 8.3 7.8 10/15/2006 18:30:00 0.4 0 0.4 0.4 0.4 0.2 1.5 0.4 0.5 0.3 1.5 0.4 120 18 165 165 8 0.1 8.3 7.5 10/15/2006 18:40:00 1.8 0.8 2.6 0.4 2 0.6 2.6 0.7 2.2 0.6 3 1.1 177 10 180 165 8 0.1 8.3 7.5 10/15/2006 18:50:00 2.3 0.4 3.4 1.5 2.4 0.4 3.8 1.9 2.6 0.4 4.2 1.9 186 11 218 165 7.7 0 8 7.3 10/15/2006 19:00:00 2.5 0.4 3.4 1.1 2.6 0.4 3.4 1.5 2.7 0.5 4.2 1.5 180 15 168 165 7.8 0 8 7.3 10/15/2006 19:10:00 1.7 1.1 3.8 0.4 1.9 1.1 3.8 0.4 2 1 3.8 0.4 198 27 208 165 7.7 0.1 8.3 7 10/15/2006 19:20:00 2.5 0.5 3.8 0.7 2.5 0.5 3.8 0.7 2.8 0.4 3.8 1.5 183 8 171 165 7.7 0 8 7.5 10/15/2006 19:30:00 2.3 0.5 3 0.7 2.3 0.5 3 0.7 2.5 0.4 3.4 1.5 180 9 197 165 7.5 0.1 7.8 7.5 10/15/2006 19:40:00 2.4 0.4 3.4 1.1 2.4 0.4 3.4 1.1 2.5 0.3 3 1.5 178 6 178 165 7.4 0.1 7.8 7.3 10/15/2006 19:50:00 3.4 0.5 4.6 2.3 3.4 0.5 4.6 2.3 3.3 0.5 4.6 2.3 177 6 177 165 7.4 0 7.8 7.3 10/15/2006 20:00:00 3.2 0.5 4.6 1.1 3.2 0.5 4.2 1.5 3.3 0.4 4.2 1.9 181 3 195 165 7.4 0 7.8 7.3 10/15/2006 20:10:00 2.7 0.8 4.9 1.5 2.7 0.8 4.9 1.1 2.8 0.8 4.9 1.5 201 10 204 165 7.3 0.1 7.8 7 10/15/2006 20:20:00 4.3 0.4 4.9 2.6 4.4 0.4 5.3 2.6 4.5 0.5 5.3 2.6 201 4 207 165 7.6 0 7.8 7.3 10/15/2006 20:30:00 3.5 0.5 4.9 2.6 3.8 0.5 4.9 3 3.7 0.5 5.3 2.6 215 5 202 165 7.6 0 8 7.3 10/15/2006 20:40:00 3.3 0.4 4.6 2.6 3.5 0.4 4.6 3 3.5 0.4 4.9 2.6 217 3 209 165 7.6 0.1 8 7.3 10/15/2006 20:50:00 5 1.2 7.6 3 5.1 1.1 7.6 3 5.1 1.1 8 3 201 14 180 165 7.9 0.1 8.5 7.5 10/15/2006 21:00:00 4.6 0.6 6.1 3.4 4.6 0.5 6.1 3 4.8 0.5 6.1 3.4 188 8 178 165 8.4 0 8.5 8 10/15/2006 21:10:00 4.7 0.7 6.8 3.4 4.7 0.6 6.8 3.4 4.9 0.8 6.8 3 189 6 197 165 8.4 0.1 8.5 8 10/15/2006 21:20:00 3.4 0.7 5.3 1.5 3.3 0.7 5.3 1.5 3.6 0.7 5.3 2.3 171 7 181 165 8.5 0.1 8.8 8 10/15/2006 21:30:00 3 0.6 4.6 1.5 3 0.5 4.6 1.5 3.2 0.5 4.6 1.9 160 8 164 165 8.4 0 8.5 8 10/15/2006 21:40:00 3 0.9 4.9 0.4 3 0.9 4.9 0.4 3.1 0.8 4.9 0.7 162 17 172 165 8.3 0.1 8.5 8 10/15/2006 21:50:00 3.3 0.7 5.3 1.5 3.5 0.7 4.9 1.5 3.4 0.6 4.9 1.9 192 10 167 165 8.5 0.1 8.8 8 10/15/2006 22:00:00 3.3 0.4 4.6 2.3 3.3 0.4 4.6 2.3 3.5 0.4 4.6 2.6 158 13 156 165 8.3 0.2 8.8 7.8 10/15/2006 22:10:00 3.6 0.6 4.9 1.9 3.6 0.6 4.9 2.3 3.8 0.5 4.9 2.6 151 7 159 165 8 0 8.5 7.5 10/15/2006 22:20:00 3.5 0.5 4.6 1.9 3.5 0.5 4.6 2.3 3.8 0.5 5.3 2.6 157 8 156 165 8.1 0 8.5 7.8 10/15/2006 22:30:00 3.8 0.6 5.3 2.6 3.8 0.6 5.3 2.6 4 0.5 5.7 3 161 8 170 165 8.1 0 8.5 8 10/15/2006 22:40:00 3.6 1 6.1 2.3 3.6 1 6.5 2.3 3.9 1 6.5 2.6 158 12 152 165 8.3 0 8.5 8 10/15/2006 22:50:00 3.8 1.1 8 0.7 3.8 1 7.6 0.7 3.9 1 7.2 1.5 164 15 152 165 8.3 0 8.8 8 10/15/2006 23:00:00 5.9 1.1 8.4 3 5.8 1.1 8 3.4 5.9 1.1 8.4 3.4 163 14 162 165 8.2 0 8.5 8 10/15/2006 23:10:00 6.7 0.9 8.4 4.6 6.6 0.8 8.8 4.9 6.8 0.8 8.8 4.6 160 9 159 165 8.1 0 8.5 8 10/15/2006 23:20:00 6.8 1 9.9 4.9 6.7 1 9.5 4.6 6.7 1 9.9 4.2 160 7 177 165 8.1 0 8.5 8 10/15/2006 23:30:00 8.9 0.7 10.7 6.8 8.7 0.7 10.3 6.8 8.7 1 11.1 6.1 163 4 157 165 8.2 0 8.5 8 10/15/2006 23:40:00 8.7 1.2 11.5 5.7 8.5 1.1 11.5 5.7 8.7 1.2 11.1 5.3 162 11 165 165 8.3 0 8.5 8 10/15/2006 23:50:00 9.3 0.9 11.5 6.5 9.1 0.9 11.1 5.7 9.3 1 11.8 6.5 163 12 165 165 8.3 0 8.5 8 10/16/2006 00:00:00 10.1 1 11.8 7.2 9.9 0.9 11.5 7.2 10 1 11.8 7.2 165 11 165 165 8.3 0 8.5 8 10/16/2006 00:10:00 9.8 0.7 11.5 7.6 9.6 0.6 11.1 7.2 9.7 0.8 11.5 6.8 167 12 171 165 8.2 0 8.5 8 10/16/2006 00:20:00 10.9 0.8 13 8.8 10.6 0.7 12.6 8.4 10.8 0.9 12.6 8.4 168 6 165 165 8.2 0 8.5 8 10/16/2006 00:30:00 11.5 1.1 13.7 8.8 11.1 1.1 13.3 8.4 11.5 1.1 13.7 8.8 168 9 168 165 8.2 0 8.5 7.8 10/16/2006 00:40:00 12.7 0.9 14.5 9.5 12.3 0.9 13.7 9.1 12.8 1 14.9 9.1 167 5 165 165 8.3 0.1 8.5 8 10/16/2006 00:50:00 13.6 0.6 14.9 11.5 13.2 0.6 14.5 11.1 13.6 0.7 15.3 11.5 166 22 164 165 8.4 0 8.5 8.3 10/16/2006 01:00:00 13.7 0.5 14.9 11.5 13.3 0.5 14.9 11.5 13.7 0.7 15.6 12.2 164 10 164 165 8.3 0.1 8.5 8 10/16/2006 01:10:00 12.8 0.7 14.1 9.9 12.6 0.6 14.1 9.9 12.8 0.8 14.1 9.5 163 9 161 165 8.3 0.1 8.5 8 10/16/2006 01:20:00 12.8 0.8 14.9 9.5 12.6 0.8 14.5 9.9 12.5 1 14.5 9.5 164 14 164 165 8.2 0 8.5 7.8 10/16/2006 01:30:00 12.2 0.8 13.7 9.5 12 0.8 13.3 9.5 12.3 0.9 14.1 9.1 166 8 162 165 8.1 0.1 8.5 7.8 10/16/2006 01:40:00 11.8 0.8 13.3 9.5 11.5 0.8 13.3 9.5 11.7 1 13.7 9.1 166 8 106 165 8.1 0.1 8.5 7.8 10/16/2006 01:50:00 12.4 0.6 14.1 10.7 12.1 0.6 13.7 9.9 12.5 0.7 14.1 10.3 164 17 165 165 8.2 0.1 8.5 7.8 10/16/2006 02:00:00 12.1 0.5 13 10.3 11.8 0.5 12.6 9.9 12.1 0.7 13.3 9.9 167 14 165 165 8.2 0.1 8.5 8 10/16/2006 02:10:00 11.3 0.7 13.3 9.1 11.1 0.7 13 8.8 11.5 0.7 13.3 8.8 166 12 165 165 8.2 0.1 8.5 7.8 10/16/2006 02:20:00 10.9 0.8 13 7.6 10.7 0.8 12.6 8 10.9 0.9 13 8 162 4 163 165 8.2 0.1 8.5 7.8 10/16/2006 02:30:00 11.3 0.7 13 8.4 11 0.7 12.6 8.4 11.1 0.9 13 8.4 163 6 164 165 8.1 0.1 8.5 7.8 10/16/2006 02:40:00 11.8 0.8 14.5 9.5 11.6 0.8 14.1 9.1 11.7 0.9 14.9 8.8 165 12 159 165 8.1 0.1 8.5 7.8 10/16/2006 02:50:00 11.7 1 14.1 8.8 11.4 0.9 13.3 8.8 11.7 1 14.1 9.1 164 11 168 165 8.1 0.1 8.5 7.8 10/16/2006 03:00:00 11.9 0.9 13.3 9.1 11.7 0.8 13.3 8.8 11.8 1 14.1 8.4 164 10 165 165 8.1 0.1 8.5 7.8 10/16/2006 03:10:00 12 0.7 13.3 9.9 11.7 0.6 13 9.5 11.8 0.8 13.3 9.5 166 17 164 165 8.1 0.1 8.5 7.8 10/16/2006 03:20:00 12.2 0.6 13.7 9.5 11.8 0.6 13 9.1 12.1 0.7 13.7 10.3 167 13 160 165 8.1 0.1 8.5 7.8 10/16/2006 03:30:00 11.8 0.8 13.3 9.5 11.3 0.7 13 9.1 11.8 0.8 13.3 9.5 167 11 166 165 8.1 0.1 8.5 7.8 10/16/2006 03:40:00 11.8 0.7 13 9.5 11.5 0.7 13 9.5 11.8 0.7 13.3 9.1 167 15 165 165 8.1 0.1 8.5 7.5 10/16/2006 03:50:00 10.9 0.8 13.3 8.4 10.6 0.8 12.6 8 10.9 0.9 13.3 8.4 168 10 165 165 8.1 0.1 8.5 7.5 10/16/2006 04:00:00 11.6 0.8 13.3 9.1 11.3 0.8 13 9.1 11.3 0.8 13.3 8.4 168 13 167 165 8.1 0.1 8.5 7.5 10/16/2006 04:10:00 10.8 0.8 12.6 8 10.4 0.8 12.2 8 10.5 0.8 12.6 8 168 8 168 165 8.1 0.1 8.5 7.5 10/16/2006 04:20:00 10.1 0.9 12.2 8 9.7 0.9 11.8 7.6 10 0.9 12.2 8 171 8 188 165 8.1 0.1 8.5 7.5 10/16/2006 04:30:00 9.1 0.8 11.1 6.5 8.7 0.8 10.7 6.1 9.3 0.8 11.8 7.2 172 8 165 165 8.1 0.1 8.5 7.8 10/16/2006 04:40:00 7.5 0.9 9.5 5.3 7.2 0.9 9.1 4.9 7.7 0.7 9.9 5.7 175 7 183 165 8.1 0.1 8.5 7.8 10/16/2006 04:50:00 6.7 1 9.1 4.2 6.5 0.8 8.4 4.2 6.8 0.7 8.8 4.6 176 8 179 165 8.1 0.1 8.5 7.8 10/16/2006 05:00:00 7.4 0.7 8.8 5.7 6.9 0.6 8.8 5.7 7.3 0.6 8.8 5.3 173 6 175 165 8.1 0.1 8.5 7.8 10/16/2006 05:10:00 7.4 0.7 9.1 5.3 7.1 0.6 8.4 5.3 7.5 0.7 9.1 5.7 171 7 165 165 8.1 0.1 8.5 7.8 10/16/2006 05:20:00 6.6 0.7 8 4.2 6.4 0.6 7.6 4.2 6.7 0.6 8 4.6 171 6 166 165 8.1 0.2 8.5 7.8 10/16/2006 05:30:00 6.8 0.6 8 5.3 6.6 0.5 8 5.3 7.1 0.6 8.4 5.7 171 6 172 165 8.2 0.2 8.5 7.8 10/16/2006 05:40:00 6.4 0.6 8.4 4.9 6.2 0.6 8 4.9 6.6 0.6 8 4.9 172 6 182 165 8.2 0.2 8.5 7.8 10/16/2006 05:50:00 6.4 0.9 8.4 4.6 6.2 0.8 8 4.6 6.5 0.8 8.4 4.9 173 7 162 165 8.3 0.2 8.5 7.8 10/16/2006 06:00:00 6.2 0.8 8 4.2 6.1 0.7 7.6 3.8 6.4 0.8 8.4 4.6 175 7 166 165 8.3 0.2 8.5 7.8 10/16/2006 06:10:00 5.8 0.6 7.2 4.2 5.6 0.6 6.8 4.2 5.8 0.6 7.6 4.6 175 6 168 165 8.3 0.2 8.5 7.8 10/16/2006 06:20:00 5.5 0.6 7.2 4.2 5.2 0.5 6.8 3.8 5.6 0.5 7.2 4.6 177 7 177 165 8.3 0.2 8.8 7.8 10/16/2006 06:30:00 6 0.5 6.8 4.2 5.7 0.5 6.8 4.2 6.3 0.5 7.6 4.9 174 5 183 165 8.3 0.2 8.8 7.8 10/16/2006 06:40:00 6.2 1 8.4 3.4 6 0.9 8 3.4 6.6 0.9 8.8 4.6 177 6 176 165 8.3 0.2 8.5 7.8 10/16/2006 06:50:00 7 1 9.1 4.6 6.7 0.9 8.8 4.2 7 0.9 9.5 4.9 175 6 177 165 8.3 0.2 8.5 7.8 10/16/2006 07:00:00 6.7 0.9 8.4 4.2 6.5 0.8 8.4 4.6 6.8 0.8 8.8 4.6 180 7 168 165 8.3 0.2 8.5 7.8 10/16/2006 07:10:00 6.8 1 9.1 4.2 6.6 0.9 8.8 4.2 7 1 9.5 4.9 179 6 179 165 8.3 0.2 8.5 7.8 10/16/2006 07:20:00 5.9 0.8 7.6 3.8 5.7 0.8 7.2 3.8 6.2 0.8 8 4.2 180 6 191 165 8.3 0.2 8.5 7.8 10/16/2006 07:30:00 5.2 0.8 6.8 3 5 0.7 6.5 2.6 5.4 0.8 7.2 3.4 176 8 178 165 8.3 0.2 8.5 7.8 10/16/2006 07:40:00 5.8 0.7 7.2 3.8 5.6 0.7 7.2 3.8 6 0.8 8 3.8 177 10 160 165 8.3 0.3 8.8 7.8 10/16/2006 07:50:00 5.6 0.7 7.2 4.2 5.4 0.6 7.2 3.8 5.9 0.6 7.6 4.2 182 8 185 165 8.3 0.3 8.8 7.8 10/16/2006 08:00:00 6.2 0.6 8 4.2 6 0.6 7.6 4.6 6.4 0.6 8.8 4.9 180 4 173 165 8.3 0.3 8.8 7.8 10/16/2006 08:10:00 6.3 0.5 7.6 4.9 6.1 0.5 7.2 4.6 6.5 0.5 7.6 5.3 176 5 179 165 8.3 0.3 8.8 7.8 10/16/2006 08:20:00 6.2 0.5 8 4.9 6 0.5 7.2 4.9 6.5 0.5 7.6 4.9 169 8 177 165 8.3 0.3 8.8 7.8 10/16/2006 08:30:00 5.9 0.7 7.2 4.2 5.7 0.7 6.8 4.2 6.1 0.7 7.6 4.2 171 6 170 165 8.3 0.3 8.8 7.8 10/16/2006 08:40:00 7.1 0.8 8.8 5.7 6.8 0.7 8.4 5.3 7.1 0.7 9.1 5.7 167 5 163 165 8.3 0.2 8.5 7.8 10/16/2006 08:50:00 8.2 0.7 9.9 6.1 7.9 0.6 9.1 6.1 8.2 0.6 9.9 6.5 169 6 175 165 8.3 0.2 8.5 7.8 10/16/2006 09:00:00 8.9 0.6 9.9 7.6 8.5 0.5 9.5 7.2 9 0.6 10.3 7.2 171 7 165 165 8.1 0 8.5 7.8 10/16/2006 09:10:00 9.1 0.7 11.1 6.8 8.7 0.6 10.7 6.8 9 0.6 10.7 7.2 169 5 166 165 8.1 0 8.3 7.8 10/16/2006 09:20:00 7.6 0.8 9.5 5.3 7.3 0.7 9.1 5.3 7.6 0.8 9.9 5.7 171 12 165 165 8.1 0 8.5 7.8 10/16/2006 09:30:00 5.7 0.9 8 3.4 5.7 0.8 8 3.8 6 0.8 8 4.2 190 10 184 165 8.3 0.2 8.5 7.8 10/16/2006 09:40:00 5.1 0.8 7.2 2.6 5.2 0.8 7.2 3 5.5 0.8 7.6 3.8 195 9 189 165 8.3 0.2 8.5 7.8 10/16/2006 09:50:00 3.7 0.8 6.1 1.5 3.8 0.8 5.7 1.5 3.8 0.6 5.7 2.6 211 9 220 165 8.6 0.4 9.6 7.5 10/16/2006 10:00:00 5.8 1.5 8.8 2.3 5.9 1.5 8.8 2.3 5.7 1.5 8.4 1.9 207 8 211 165 8.8 0.4 9.6 8.3 10/16/2006 10:10:00 6.2 0.9 8 3.4 6.1 1 8.4 3.4 6.5 0.8 8.4 4.2 184 14 200 165 9 0.4 9.8 8.5 10/16/2006 10:20:00 6.3 0.8 8.4 4.6 6.1 0.8 8 4.2 6.5 0.7 8.4 4.9 173 13 194 165 9.6 0.1 9.8 9 10/16/2006 10:30:00 4.5 1 6.8 1.5 4.4 1 6.5 1.5 4.8 1 7.6 2.3 179 12 181 165 9.7 0 10.1 9 10/16/2006 10:40:00 4.4 0.9 7.2 1.9 4.3 0.9 7.2 1.9 4.6 0.8 6.5 2.6 182 13 190 165 10.2 0.1 10.9 9.6 10/16/2006 10:50:00 6 1 8.8 3 5.8 1 8.8 3 6.3 0.9 9.9 4.2 163 9 168 165 9.6 0 9.8 9.6 10/16/2006 11:00:00 6.6 1 9.1 4.6 6.3 0.9 8.8 3.8 6.7 1 9.5 4.2 171 12 166 165 9.7 0.1 9.8 9.3 10/16/2006 11:10:00 7.4 0.7 9.1 5.3 7.1 0.6 8.8 5.3 7.6 0.7 9.5 5.3 176 13 178 165 9.6 0 9.8 9 10/16/2006 11:20:00 6.5 1.1 9.1 3 6.3 1.1 9.1 3 6.7 1.1 9.1 3.8 181 12 182 165 9.6 0.1 9.8 9.3 10/16/2006 11:30:00 5.8 0.9 8 3.8 5.7 1 8 3.4 5.9 1 8.4 3.8 184 11 192 165 10 0 10.6 9.6 10/16/2006 11:40:00 6.6 0.9 8.8 3.8 6.4 0.9 8.4 3.4 6.8 0.8 9.1 4.2 181 14 176 165 10.2 0.1 10.6 9.8 10/16/2006 11:50:00 6.4 0.8 9.9 4.6 6.1 0.8 9.5 3.8 6.7 0.8 8.8 4.6 170 11 180 165 10.2 0 10.6 9.8 10/16/2006 12:00:00 6.6 0.7 8 4.2 6.2 0.7 7.6 4.2 6.8 0.7 8.4 4.9 170 10 168 165 10.5 0 10.9 10.3 10/16/2006 12:10:00 6.4 0.7 8 4.2 6.1 0.7 8 3.8 6.6 0.6 8 4.6 168 10 167 165 11 0.1 11.4 10.6 10/16/2006 12:20:00 6 0.6 8 3.8 5.8 0.6 7.6 3.4 6.3 0.7 8 4.6 166 8 165 165 11.3 0.1 11.7 11.1 10/16/2006 12:30:00 6 1 8.8 3.8 5.8 1 8.4 3.4 6.3 0.8 8.4 3.8 173 13 165 165 11.5 0 11.9 11.4 10/16/2006 12:40:00 7.4 1 10.7 4.9 7.1 1 10.3 4.6 7.7 0.9 10.3 5.3 178 9 181 165 11.1 0 11.7 11.1 10/16/2006 12:50:00 6.9 0.8 9.1 4.9 6.7 0.8 8.8 4.6 7.1 0.8 9.1 4.9 179 8 179 165 11.1 0.1 11.7 10.9 10/16/2006 13:00:00 6.2 0.7 8 4.2 6 0.7 8 4.2 6.3 0.8 8 4.2 175 9 178 165 11.6 0.1 11.9 11.1 10/16/2006 13:10:00 6.9 0.8 8.8 4.6 6.7 0.8 8.4 4.6 7.1 0.7 9.1 4.9 176 7 178 165 11.5 0.1 11.9 11.4 10/16/2006 13:20:00 7.3 0.6 8.8 5.3 7.1 0.6 8.4 5.3 7.5 0.7 9.1 5.7 185 7 199 165 11.4 0 11.7 11.1 10/16/2006 13:30:00 7.4 0.6 8.8 5.3 7.2 0.6 8.4 5.3 7.6 0.7 9.1 5.3 185 6 189 165 11.3 0 11.7 11.1 10/16/2006 13:40:00 7.5 0.6 9.1 5.7 7.3 0.6 9.1 5.7 7.8 0.8 9.5 5.3 182 8 176 165 11.4 0 11.7 11.1 10/16/2006 13:50:00 6.5 0.8 9.5 3.8 6.4 0.8 9.1 4.2 6.7 0.8 8.4 4.2 181 9 184 165 11.6 0 11.9 11.4 10/16/2006 14:00:00 6.3 0.9 8.8 3.8 6.1 0.8 8 3.8 6.5 0.8 8.4 4.2 178 8 165 165 11.6 0 11.9 11.4 10/16/2006 14:10:00 6.9 0.7 8.4 4.9 6.7 0.7 8.4 4.9 7 0.8 8.8 4.6 177 9 165 165 11.5 0 11.7 11.4 10/16/2006 14:20:00 6.8 1 9.5 4.6 6.6 1 9.5 4.2 6.9 1 9.9 4.6 175 10 170 165 11.4 0 11.7 11.1 10/16/2006 14:30:00 6.3 0.8 8 3 6.1 0.7 8 2.6 6.6 0.7 8.4 4.2 172 10 177 165 11.5 0 11.7 11.4 10/16/2006 14:40:00 5.8 1 8 4.2 5.6 0.9 8 3.8 6.2 1 8.4 4.2 173 11 186 165 11.5 0 11.7 11.4 10/16/2006 14:50:00 6.7 0.9 8.8 4.2 6.5 0.8 8.8 4.2 6.7 0.9 8.4 4.2 179 9 166 165 11.5 0 11.9 11.4 10/16/2006 15:00:00 5.2 1.2 7.6 2.6 5.1 1.1 7.2 2.6 5.5 1.2 8 3 179 8 178 165 11.6 0 12.2 11.4 10/16/2006 15:10:00 4.9 0.7 6.8 3.4 4.9 0.7 6.8 3.4 5.1 0.8 6.8 3 188 12 191 165 11.9 0 12.2 11.7 10/16/2006 15:20:00 5.6 1 8 3.4 5.5 1 8 3.4 5.9 1.1 8.8 3 187 17 206 165 11.6 0 12.2 11.4 10/16/2006 15:30:00 5.2 1 7.2 2.3 5.2 1 7.2 2.3 5.3 1.1 8 3 198 14 198 165 11.9 0.1 12.5 11.7 10/16/2006 15:40:00 5.2 1 7.6 2.3 5.3 1 7.6 2.3 5.2 1 7.6 3.4 210 17 215 165 11.8 0.1 12.5 11.7 10/16/2006 15:50:00 6.5 1 8.8 3.8 6.7 1 8.8 3.8 6.7 1 9.1 3.8 218 9 224 165 11.7 0.2 12.5 11.4 10/16/2006 16:00:00 7.1 0.8 8.8 4.6 7.3 0.8 9.1 4.9 7.2 0.8 9.1 5.3 219 5 218 165 11.3 0 11.7 11.1 10/16/2006 16:10:00 6.2 1.1 8.4 3.8 6.4 1.2 8.8 3.8 6.2 1.3 9.1 3.4 215 9 219 165 11 0 11.4 10.9 10/16/2006 16:20:00 6.4 1 8.4 4.2 6.7 1 8.8 4.6 6.4 1 8.4 3.4 217 7 211 165 10.9 0 11.4 10.9 10/16/2006 16:30:00 6 1.3 8.4 2.6 6.2 1.4 8.8 2.6 6.2 1.5 9.1 3 218 9 212 165 10.7 0 10.9 10.6 10/16/2006 16:40:00 6.2 1 8 2.6 6.5 1.1 8.4 2.6 6.2 1.2 8.4 3 217 7 221 165 10.4 0.2 10.9 10.1 10/16/2006 16:50:00 4.9 1.1 7.2 2.3 5.1 1.1 7.6 2.6 4.8 1.1 6.8 1.9 213 13 223 165 10.1 0 10.6 10.1 10/16/2006 17:00:00 5.2 0.8 7.6 3.4 5.3 0.9 7.6 3.8 5.1 0.8 7.2 2.6 193 11 201 165 9.9 0.1 10.3 9.6 10/16/2006 17:10:00 6.2 1.1 8.8 3.8 6.3 1.1 8.4 3.8 6.3 1.2 8.8 3.4 191 10 182 165 9.4 0 9.8 9 10/16/2006 17:20:00 6.8 0.8 8.8 4.9 6.9 0.8 8.8 4.9 6.8 0.7 8.4 5.3 199 7 205 165 8.9 0 9.3 8.3 10/16/2006 17:30:00 5.7 0.8 7.6 3.8 5.9 0.8 7.6 3.8 5.7 0.8 8 3.4 206 7 204 165 8.7 0 9 8.5 10/16/2006 17:40:00 6.2 0.8 8 4.2 6.4 0.8 8 4.2 6.1 1 8.4 3.8 219 8 215 165 8.4 0 8.8 8 10/16/2006 17:50:00 5 1 6.8 2.3 5.2 1 7.2 2.3 4.7 1 7.2 1.9 222 9 219 165 8 0.1 8.5 7.5 10/16/2006 18:00:00 4.9 0.6 6.1 2.6 5.1 0.6 6.5 3.4 4.7 0.7 6.1 3 216 6 224 165 7.8 0.2 8.3 7.3 10/16/2006 18:10:00 5.5 0.6 6.8 3.4 5.7 0.6 7.2 3.4 5.4 0.7 7.6 3.4 220 5 216 165 7.8 0 8 7.3 10/16/2006 18:20:00 5.1 0.6 6.5 3 5.3 0.6 6.5 3.4 5.1 0.7 6.5 3 210 7 211 165 7.8 0 8 7.5 10/16/2006 18:30:00 5.4 0.8 7.2 3 5.6 0.8 7.6 3.4 5.4 0.8 6.8 2.6 211 7 211 165 7.7 0 8.3 7.5 10/16/2006 18:40:00 5.7 0.5 6.8 4.6 5.9 0.5 7.2 4.6 5.7 0.6 7.2 3.8 207 5 216 165 7.5 0.1 7.8 7.3 10/16/2006 18:50:00 4.9 0.6 6.1 3 5 0.5 6.1 3.4 4.9 0.5 6.1 3.8 201 5 198 165 7.3 0.1 7.8 6.7 10/16/2006 19:00:00 5.6 0.4 6.5 4.6 5.5 0.4 6.5 4.6 5.8 0.4 6.8 4.9 187 6 195 165 7.3 0.1 7.5 6.7 10/16/2006 19:10:00 5.8 0.5 6.8 4.9 5.8 0.5 6.8 4.9 6 0.5 7.2 4.6 188 3 186 165 7.3 0.1 7.5 6.5 10/16/2006 19:20:00 6.3 0.4 7.6 4.6 6.2 0.4 7.2 4.9 6.4 0.5 8 4.9 186 3 185 165 7.2 0 7.5 6.7 10/16/2006 19:30:00 5.6 0.4 6.8 4.6 5.5 0.4 6.8 4.6 5.6 0.5 6.8 4.2 185 4 189 165 6.9 0.1 7.3 6.7 10/16/2006 19:40:00 5.3 0.5 6.8 4.6 5.3 0.4 6.8 4.6 5.6 0.4 6.8 4.9 191 4 187 165 6.9 0 7.3 6.7 10/16/2006 19:50:00 5.8 0.4 6.5 4.6 5.7 0.4 6.5 4.9 6.1 0.4 6.8 4.9 184 4 177 165 6.8 0 7 6.7 10/16/2006 20:00:00 5.3 0.4 6.5 4.2 5.2 0.4 6.1 4.2 5.4 0.4 6.5 4.6 180 4 183 165 6.7 0 7.3 6.2 10/16/2006 20:10:00 4.9 0.4 5.7 3.8 4.8 0.4 5.7 3.8 5 0.4 6.1 3.8 186 4 187 165 6.5 0.1 7 6 10/16/2006 20:20:00 5.2 0.3 6.1 4.6 5.2 0.3 6.1 4.6 5.4 0.3 6.1 4.6 188 4 183 165 6.3 0.1 6.7 5.7 10/16/2006 20:30:00 4.9 0.4 6.1 3.8 4.9 0.4 6.1 3.8 5.1 0.4 6.1 4.2 189 4 187 165 6.4 0.1 6.7 5.7 10/16/2006 20:40:00 5.4 0.3 6.1 4.6 5.4 0.3 6.1 4.6 5.6 0.3 6.5 4.9 188 3 192 165 6.5 0 6.7 6.2 10/16/2006 20:50:00 5.7 0.3 6.5 4.9 5.8 0.3 6.5 4.9 5.9 0.4 6.8 4.6 193 5 187 165 6.3 0.1 6.7 6 10/16/2006 21:00:00 6.2 0.8 8 4.6 6.3 0.9 8.4 4.6 6.5 0.8 8.4 4.6 199 2 199 165 6.2 0.1 6.7 5.7 10/16/2006 21:10:00 5.7 0.5 6.8 4.9 5.8 0.5 6.8 4.9 5.9 0.4 6.8 4.9 201 3 201 165 6.2 0.1 6.7 6 10/16/2006 21:20:00 4.6 0.5 6.1 3.4 4.7 0.5 6.5 3.4 4.8 0.5 6.1 3.8 199 4 198 165 6.1 0.2 6.2 5.5 10/16/2006 21:30:00 6.5 0.5 8 5.3 6.6 0.5 8 5.3 6.8 0.6 8.8 5.7 198 3 198 165 5.9 0.3 6.2 5.5 10/16/2006 21:40:00 7.6 0.8 9.5 5.7 7.6 0.8 9.1 5.7 7.7 0.8 9.5 6.1 195 4 197 165 5.9 0.2 6.2 5.5 10/16/2006 21:50:00 6.7 0.6 8 5.3 6.6 0.6 8 5.3 6.8 0.6 8.4 5.3 200 5 196 165 6 0 6.2 5.2 10/16/2006 22:00:00 6.2 0.6 7.2 4.6 6.5 0.6 7.6 4.9 6.4 0.7 8 4.9 204 3 203 165 6.1 0.1 6.2 5.5 10/16/2006 22:10:00 5.4 0.5 6.5 3 5.6 0.5 6.8 3.4 5.5 0.6 6.8 3.8 208 3 211 165 6.1 0 6.2 5.5 10/16/2006 22:20:00 5.6 0.4 6.8 4.6 5.8 0.4 6.8 4.6 5.6 0.5 6.8 4.2 205 4 198 165 6.2 0 6.2 6 10/16/2006 22:30:00 5.3 0.8 7.2 3 5.3 0.8 7.2 3 5.5 0.8 6.8 3.4 194 6 199 165 6.1 0 6.2 5.7 10/16/2006 22:40:00 3.7 0.4 4.6 2.6 3.7 0.4 4.6 3 3.8 0.4 4.6 3 194 5 199 165 5.7 0.1 6.2 5.2 10/16/2006 22:50:00 3.7 0.4 4.6 3 3.7 0.4 4.6 3 4.1 0.3 4.9 3 199 3 201 165 5.8 0 6.2 5.5 10/16/2006 23:00:00 3.6 0.3 4.2 3 3.6 0.3 4.6 3 3.9 0.3 4.6 3 197 5 206 165 5.9 0.1 6.2 5.7 10/16/2006 23:10:00 3.5 0.3 4.2 3 3.6 0.3 4.2 3 4.1 0.3 4.9 3.4 194 4 189 165 6 0 6.2 5.7 10/16/2006 23:20:00 4.1 0.3 4.6 3.4 4.1 0.2 4.6 3.4 4.5 0.3 5.3 3.8 190 5 193 165 6 0 6.2 5.7 10/16/2006 23:30:00 4.5 0.4 5.3 3.8 4.4 0.3 5.3 3.8 4.9 0.4 5.7 3.8 184 9 187 165 6.1 0 6.2 5.7 10/16/2006 23:40:00 4.1 0.5 5.3 3 4 0.5 4.9 3 4.5 0.5 5.7 3.4 181 4 177 165 5.9 0.2 6.2 5.5 10/16/2006 23:50:00 4.3 0.6 5.7 3.4 4.2 0.5 5.7 3 4.5 0.5 6.1 3.8 183 6 194 165 5.9 0.1 6.2 5.5 10/17/2006 00:00:00 3.7 0.6 4.9 2.3 3.6 0.5 4.6 2.3 3.8 0.6 5.3 2.6 172 6 176 165 5.8 0.2 6.5 5.2 10/17/2006 00:10:00 3 0.5 3.8 1.5 2.9 0.4 3.8 1.5 3.2 0.4 4.2 2.3 174 7 176 165 5.7 0.2 6 5 10/17/2006 00:20:00 3.3 0.4 4.2 2.3 3.2 0.4 3.8 2.3 3.3 0.5 4.6 1.9 171 4 180 165 5.8 0.1 6.2 5.2 10/17/2006 00:30:00 3.1 0.5 4.6 1.9 3.1 0.4 4.2 1.9 3.4 0.4 4.6 2.6 162 8 168 165 5.9 0.1 6.2 5.2 10/17/2006 00:40:00 3.5 0.5 4.9 2.3 3.4 0.5 4.6 2.3 3.6 0.5 4.9 2.6 177 5 174 165 5.9 0 6 5.5 10/17/2006 00:50:00 4 0.4 4.9 3 3.9 0.3 4.6 3 4.1 0.4 4.9 3.4 179 3 179 165 5.8 0.1 6 5.5 10/17/2006 01:00:00 3.7 0.3 4.6 3 3.7 0.2 4.6 3 4.1 0.2 4.6 3.4 182 3 180 165 5.8 0.1 6 5.2 10/17/2006 01:10:00 3.6 0.2 4.2 3.4 3.5 0.2 4.2 3 4.1 0.2 4.6 3.4 180 9 192 165 6.1 0.1 6.2 5.5 10/17/2006 01:20:00 3.5 0.4 4.6 2.3 3.4 0.4 4.2 2.3 3.8 0.4 4.6 3 185 5 172 165 6 0 6.2 5.5 10/17/2006 01:30:00 3.3 0.2 3.8 2.6 3.2 0.2 3.8 2.6 3.6 0.3 4.2 3 183 2 180 165 6.1 0 6.2 5.5 10/17/2006 01:40:00 3.1 0.2 3.8 2.3 3.1 0.2 3.8 2.3 3.5 0.4 4.2 2.6 178 6 179 165 6.1 0 6.2 6 10/17/2006 01:50:00 2 0.6 3 0.7 2.1 0.6 3 0.7 2.6 0.5 3.4 1.5 177 8 166 165 6 0.1 6.2 5.7 10/17/2006 02:00:00 1.2 0.5 2.3 0.4 1.2 0.5 2.3 0.4 2 0.3 2.6 1.1 191 12 196 165 5.7 0 6 5.7 10/17/2006 02:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 1 0.4 1.9 0.4 166 0 165 165 5.8 0 6 5.7 10/17/2006 02:20:00 1.1 0.8 2.6 0.4 1 0.7 2.6 0.4 1.7 0.6 3 0.4 175 6 173 165 5.9 0 6.2 5.7 10/17/2006 02:30:00 2.4 0.3 3 1.9 2.3 0.2 3 1.9 2.7 0.3 3.4 2.3 174 4 178 165 6.2 0 6.5 6 10/17/2006 02:40:00 2.8 0.5 3.8 1.1 2.7 0.4 3.8 1.5 2.9 0.4 3.8 1.5 170 6 178 165 6.2 0 6.5 6 10/17/2006 02:50:00 2.6 0.3 3.4 1.5 2.5 0.3 3 1.1 2.9 0.3 3.8 2.3 166 4 179 165 6.1 0 6.2 5.5 10/17/2006 03:00:00 2.2 0.4 3.4 1.1 2.1 0.4 3 1.1 2.6 0.3 3.4 1.9 160 8 176 165 5.9 0 6.7 5.7 10/17/2006 03:10:00 1.7 0.5 3 0.4 1.6 0.6 3 0.4 2.3 0.4 3.4 1.1 154 8 143 165 5.7 0 6 5.2 10/17/2006 03:20:00 1.6 0.3 2.3 0.7 1.6 0.3 2.3 0.7 2.2 0.2 2.6 1.5 144 12 162 165 5.7 0.1 6 5.2 10/17/2006 03:30:00 1.2 0.4 2.3 0.4 1.2 0.4 1.9 0.4 1.9 0.3 2.3 1.1 147 20 163 165 5.6 0 5.7 5.2 10/17/2006 03:40:00 0.4 0.2 1.1 0.4 0.4 0.1 1.1 0.4 1.2 0.3 1.9 0.4 177 2 176 165 5.7 0.1 6 5.5 10/17/2006 03:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.8 0.3 1.5 0.4 178 0 165 165 5.9 0 6.2 5.5 10/17/2006 04:00:00 0.7 0.5 1.9 0.4 0.7 0.4 1.5 0.4 1.6 0.4 2.3 0.7 169 4 164 165 5.8 0.1 6 5.2 10/17/2006 04:10:00 1.6 0.7 2.6 0.4 1.5 0.6 2.6 0.4 2.1 0.6 3 0.7 164 2 163 165 6 0 6.2 5.5 10/17/2006 04:20:00 2 0.2 2.6 1.5 2 0.2 2.6 1.5 2.4 0.2 3 1.9 161 2 164 165 5.9 0 6.2 5.5 10/17/2006 04:30:00 1.5 0.6 2.6 0.4 1.5 0.6 2.6 0.4 2 0.4 3 1.1 156 4 158 165 5.8 0.1 6 5.2 10/17/2006 04:40:00 0.4 0 0.4 0.4 0.4 0.1 1.1 0.4 1 0.5 1.9 0.4 156 8 165 165 5.7 0.1 6 5.2 10/17/2006 04:50:00 0.4 0 0.4 0.4 0.4 0 0.7 0.4 0.9 0.3 1.5 0.4 182 17 165 165 5.6 0.1 5.7 5 10/17/2006 05:00:00 1 0.7 2.3 0.4 1.1 0.7 2.3 0.4 2 0.7 3 0.7 187 17 167 165 5.8 0.1 6 5.2 10/17/2006 05:10:00 1.3 0.5 2.3 0.4 1.4 0.5 2.3 0.4 2 0.2 2.6 1.5 196 9 178 165 5.7 0 6 5.7 10/17/2006 05:20:00 1.1 0.3 1.5 0.4 1.2 0.3 1.9 0.4 2.3 0.2 2.6 1.9 204 2 203 165 5.7 0 5.7 5.5 10/17/2006 05:30:00 1.4 0.6 2.3 0.4 1.6 0.5 2.3 0.4 2.3 0.3 2.6 1.5 182 15 179 165 5.8 0.1 6.2 5.7 10/17/2006 05:40:00 1.2 0.4 1.9 0.4 1.1 0.4 1.9 0.4 1.8 0.3 2.6 1.1 174 9 165 165 6 0 6.2 5.7 10/17/2006 05:50:00 1.8 0.3 2.6 1.1 1.8 0.3 2.3 1.1 2.1 0.3 2.6 1.5 180 4 181 165 5.6 0 6 5.5 10/17/2006 06:00:00 1.5 0.3 1.9 0.4 1.7 0.3 2.3 0.7 2.2 0.2 2.6 1.5 189 5 190 165 5.6 0.1 5.7 5.5 10/17/2006 06:10:00 0.4 0.1 1.1 0.4 0.5 0.3 1.5 0.4 1.3 0.3 1.9 0.4 225 45 293 165 5.7 0 6 5.7 10/17/2006 06:20:00 0.4 0 0.7 0.4 0.4 0.1 1.1 0.4 0.8 0.3 1.5 0.4 293 23 310 165 5.7 0 6 5.7 10/17/2006 06:30:00 0.4 0 0.4 0.4 0.5 0.2 1.1 0.4 1.5 0.3 1.9 0.7 195 19 165 165 5.9 0 6 5.7 10/17/2006 06:40:00 0.4 0 0.4 0.4 0.4 0.2 1.5 0.4 1.1 0.4 1.9 0.4 183 0 165 165 5.9 0 6 5.7 10/17/2006 06:50:00 0.4 0 0.4 0.4 0.6 0.3 1.1 0.4 1.6 0.2 1.9 1.1 203 11 165 165 5.9 0 6 5.7 10/17/2006 07:00:00 0.4 0 0.4 0.4 0.5 0.2 1.1 0.4 1.4 0.4 1.9 0.7 213 0 165 165 5.9 0 6.2 5.7 10/17/2006 07:10:00 0.4 0.2 1.5 0.4 0.5 0.3 1.5 0.4 1.2 0.3 1.9 0.7 279 43 315 165 6.1 0 6.2 6 10/17/2006 07:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.8 0.3 1.5 0.4 280 19 165 165 6.1 0.1 6.2 5.7 10/17/2006 07:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.7 0.3 1.1 0.4 266 0 165 165 6.3 0 6.5 6.2 10/17/2006 07:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 266 0 165 165 6 0.1 6.2 5.7 10/17/2006 07:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.5 0.3 1.1 0.4 266 0 165 165 5.9 0.1 6.2 5.7 10/17/2006 08:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.9 0.2 1.1 0.4 310 26 165 165 5.9 0 6 5.7 10/17/2006 08:10:00 0.4 0.1 0.7 0.4 0.4 0.1 0.7 0.4 1.2 0.3 1.9 0.7 325 0 325 165 5.9 0.1 6 5.5 10/17/2006 08:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.5 0.3 1.5 0.4 325 0 165 165 5.5 0 5.7 5.5 10/17/2006 08:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0.1 1.1 0.4 220 22 165 165 5.5 0 6 5.2 10/17/2006 08:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 215 0 165 165 5.9 0 6 5.7 10/17/2006 08:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 215 0 165 165 6.6 0.3 7.3 6 10/17/2006 09:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 211 19 165 165 6.6 0 7 6 10/17/2006 09:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.5 0.3 1.5 0.4 113 8 165 165 6.6 0.1 7 6 10/17/2006 09:20:00 0.6 0.5 2.6 0.4 0.6 0.6 2.6 0.4 1.3 0.8 3 0.4 56 9 44 165 6.8 0.1 7.3 6.2 10/17/2006 09:30:00 0.5 0.4 1.9 0.4 0.6 0.4 2.3 0.4 1 0.7 2.6 0.4 85 30 124 165 7.9 0.6 8.8 6.7 10/17/2006 09:40:00 1.7 0.7 3 0.4 1.7 0.8 3 0.4 2.2 0.5 3 1.1 42 7 46 165 8.7 0.2 9 8 10/17/2006 09:50:00 0.7 0.4 2.3 0.4 0.7 0.4 2.3 0.4 1.4 0.7 3 0.4 76 41 106 165 8.7 0.2 9 8.3 10/17/2006 10:00:00 0.6 0.4 1.9 0.4 0.5 0.4 2.3 0.4 1.1 0.5 2.3 0.4 356 47 49 165 9.6 0.3 10.3 8.8 10/17/2006 10:10:00 1.7 0.9 3.4 0.4 1.3 0.8 3 0.4 1.7 1 3.4 0.4 203 41 168 165 10 0.2 10.9 9.3 10/17/2006 10:20:00 1.7 0.8 3.4 0.4 1.2 0.8 3 0.4 1.8 0.8 3.8 0.4 169 12 162 165 8.9 0.1 9.6 8.5 10/17/2006 10:30:00 1.1 0.6 2.3 0.4 0.7 0.5 1.9 0.4 1.3 0.6 2.6 0.4 157 14 153 165 8.9 0 9 8.5 10/17/2006 10:40:00 2.3 0.6 3.8 0.4 2.1 0.8 3.8 0.4 2.5 0.6 4.2 1.1 145 17 122 165 9 0 9 8.8 10/17/2006 10:50:00 2.4 0.7 4.2 0.7 2.3 0.8 3.8 0.4 2.6 0.6 3.8 0.4 140 15 140 165 8.7 0.2 9 8.3 10/17/2006 11:00:00 2.8 0.5 4.2 1.9 2.8 0.5 4.2 1.5 2.9 0.5 4.2 1.5 149 13 157 165 8.6 0 9 8.3 10/17/2006 11:10:00 2.7 0.9 4.9 0.4 2.7 0.9 4.6 0.4 2.8 0.7 4.9 0.7 150 13 161 165 8.9 0 9.3 8.5 10/17/2006 11:20:00 1.3 0.6 2.6 0.4 1.3 0.6 2.6 0.4 1.5 0.6 2.6 0.4 176 21 139 165 9 0.2 9.6 8.5 10/17/2006 11:30:00 2.7 0.8 4.6 1.1 2.7 0.8 4.6 0.7 2.8 1 4.6 0.4 148 20 165 165 9.2 0.1 9.6 8.8 10/17/2006 11:40:00 2.9 0.4 4.6 1.5 2.8 0.5 4.6 1.5 3 0.5 4.6 1.9 154 12 160 165 8.9 0 9.3 8.5 10/17/2006 11:50:00 3 0.6 5.3 1.5 2.9 0.6 4.9 1.1 3.1 0.6 5.3 1.9 159 14 176 165 9 0.1 9.3 8.5 10/17/2006 12:00:00 3 0.7 4.6 1.5 3 0.7 4.6 1.5 3.1 0.6 4.6 1.5 154 10 157 165 9.1 0.2 9.6 8.5 10/17/2006 12:10:00 2.4 0.6 3.8 0.7 2.4 0.6 3.8 0.7 2.5 0.6 3.8 1.1 153 20 150 165 9.3 0 9.8 9 10/17/2006 12:20:00 1.9 0.5 3 1.1 1.8 0.5 3.4 0.7 2.2 0.5 3.8 0.7 162 22 162 165 9.3 0 9.6 9 10/17/2006 12:30:00 2 0.8 4.6 0.4 2 0.8 4.6 0.4 2.3 0.7 4.2 1.1 156 12 145 165 9.5 0.1 9.6 9 10/17/2006 12:40:00 3.1 0.6 4.9 1.9 3 0.6 4.9 1.9 3.2 0.6 4.6 1.5 158 12 145 165 9.1 0.1 9.6 8.8 10/17/2006 12:50:00 2.8 0.6 5.7 1.5 2.7 0.6 5.7 1.5 2.9 0.6 5.3 1.9 153 11 164 165 9 0 9.3 8.8 10/17/2006 13:00:00 2.1 0.5 3.4 0.7 2.1 0.5 3.4 1.1 2.2 0.6 4.2 1.1 152 14 191 165 9 0 9.6 8.8 10/17/2006 13:10:00 2.5 0.5 3.8 0.7 2.6 0.6 4.2 1.1 2.6 0.5 4.6 1.1 149 21 177 165 9.6 0.3 10.6 9 10/17/2006 13:20:00 2.2 0.6 3.8 0.7 2.2 0.7 4.2 0.7 2.3 0.7 4.2 0.7 162 21 156 165 10 0 10.6 9.6 10/17/2006 13:30:00 2 0.6 4.2 0.4 2.1 0.6 4.2 0.4 2.3 0.7 4.2 0.7 167 10 170 165 9.9 0.2 10.3 9.6 10/17/2006 13:40:00 2.4 0.6 3.8 0.4 2.4 0.6 3.8 0.7 2.6 0.6 4.2 1.1 152 17 176 165 9.9 0.1 10.3 9.6 10/17/2006 13:50:00 2.6 0.8 4.9 0.7 2.6 0.8 4.9 0.7 2.9 0.7 4.6 1.5 152 14 154 165 10.3 0 10.6 9.8 10/17/2006 14:00:00 3.3 0.6 4.9 1.9 3.3 0.6 4.9 1.9 3.4 0.5 4.9 2.3 149 11 148 165 10.2 0.3 10.9 9.6 10/17/2006 14:10:00 2.8 0.7 5.3 1.1 2.8 0.7 4.9 0.7 2.9 0.6 4.6 1.1 137 17 133 165 9.6 0.1 10.1 9.3 10/17/2006 14:20:00 2.7 0.7 4.6 1.1 2.7 0.8 4.6 1.1 2.8 0.7 4.9 1.1 141 15 165 165 9.8 0 10.3 9.3 10/17/2006 14:30:00 2.9 0.6 4.9 1.5 2.9 0.6 4.6 1.5 3.1 0.6 4.9 1.5 149 15 139 165 9.9 0.1 10.3 9.6 10/17/2006 14:40:00 2.4 0.5 4.2 1.1 2.4 0.5 3.8 1.1 2.5 0.6 4.2 1.1 140 13 142 165 9.8 0 10.1 9.6 10/17/2006 14:50:00 2.5 0.5 4.2 1.5 2.5 0.5 3.8 1.5 2.6 0.5 3.8 1.5 143 14 126 165 9.9 0 10.1 9.6 10/17/2006 15:00:00 2.8 0.5 4.2 1.5 2.9 0.5 4.2 1.5 2.9 0.5 3.8 1.1 137 12 128 165 9.7 0.2 10.1 9.3 10/17/2006 15:10:00 2.7 0.6 4.2 1.1 2.7 0.6 4.6 0.7 2.9 0.4 3.8 1.9 139 12 145 165 9.4 0 9.8 9 10/17/2006 15:20:00 2.7 0.4 4.2 1.5 2.7 0.4 4.2 1.5 2.8 0.4 4.2 1.9 134 10 121 165 8.9 0.2 9.3 8.5 10/17/2006 15:30:00 2.4 0.5 4.2 1.1 2.5 0.5 3.8 1.1 2.4 0.4 3.4 1.1 137 15 143 165 8.9 0 9 8.5 10/17/2006 15:40:00 1.8 0.5 3 0.4 1.9 0.5 3 0.7 1.9 0.5 3 0.4 133 14 135 165 8.9 0 9.3 8.5 10/17/2006 15:50:00 2.3 0.6 4.2 1.1 2.4 0.5 4.2 1.1 2.5 0.5 3.8 1.1 129 14 120 165 8.9 0.2 9.3 8.5 10/17/2006 16:00:00 2.5 0.5 3.8 1.5 2.5 0.5 3.8 1.5 2.5 0.4 3.8 1.9 112 9 121 165 8 0.1 8.5 7.8 10/17/2006 16:10:00 2.5 0.4 3.8 1.1 2.6 0.4 3.8 1.5 2.6 0.4 3.4 1.5 120 7 127 165 8 0 8.3 7.8 10/17/2006 16:20:00 2.4 0.3 3.4 1.5 2.5 0.3 3.4 1.9 2.6 0.3 3.4 1.9 113 8 106 165 8 0 8.3 7.8 10/17/2006 16:30:00 2.7 0.4 3.4 1.5 2.8 0.4 3.8 1.5 2.8 0.3 3.4 1.9 116 5 116 165 7.6 0.2 8 7.3 10/17/2006 16:40:00 3.4 0.3 4.2 2.3 3.4 0.3 4.2 2.3 3.4 0.3 4.2 2.3 123 6 121 165 7 0.1 7.3 6.7 10/17/2006 16:50:00 3.9 0.2 4.6 3 3.9 0.2 4.2 3 4 0.3 4.6 3 140 5 145 165 6.7 0 7 6.5 10/17/2006 17:00:00 4.3 0.4 5.3 3.4 4.3 0.4 5.3 3.4 4.3 0.4 5.3 3 140 3 139 165 6.4 0 6.7 6.2 10/17/2006 17:10:00 4.4 0.3 5.3 3.4 4.4 0.3 5.3 3.4 4.4 0.4 5.3 3.4 137 3 147 165 6.2 0 6.2 6 10/17/2006 17:20:00 3.8 0.4 4.9 2.6 4 0.4 4.9 3 3.9 0.4 4.9 3 130 6 135 165 6.3 0 6.5 6.2 10/17/2006 17:30:00 3.6 0.3 4.2 2.6 3.7 0.3 4.6 3 3.8 0.3 4.6 3 126 6 121 165 6.3 0 6.5 6.2 10/17/2006 17:40:00 3.9 0.4 5.3 3 4.1 0.4 5.3 3 4.1 0.3 4.9 3.4 134 6 141 165 6.3 0 6.5 6.2 10/17/2006 17:50:00 4.4 0.5 6.1 3 4.5 0.5 6.1 3 4.6 0.5 6.1 3.4 137 8 144 165 6.4 0 6.7 6.2 10/17/2006 18:00:00 4.4 0.5 6.1 3.4 4.5 0.5 5.7 3.4 4.6 0.4 5.7 3.4 149 8 162 165 6.5 0 6.7 6.2 10/17/2006 18:10:00 4.3 0.6 6.1 2.3 4.4 0.6 6.1 2.6 4.4 0.6 6.1 3 154 10 148 165 6.5 0 6.7 6.2 10/17/2006 18:20:00 4.9 0.9 6.8 2.6 5 0.8 6.8 2.6 5 0.8 6.5 3.4 155 9 157 165 6.3 0.1 6.7 6 10/17/2006 18:30:00 5.6 0.4 6.8 4.6 5.5 0.4 6.8 4.2 5.7 0.4 6.8 4.6 164 6 157 165 6.3 0 6.5 6 10/17/2006 18:40:00 5.4 0.4 6.5 4.6 5.3 0.4 6.1 4.6 5.4 0.3 6.1 4.6 168 8 167 165 6.2 0 6.5 6 10/17/2006 18:50:00 5.5 0.3 6.5 4.6 5.3 0.3 6.1 4.6 5.5 0.3 6.1 4.6 168 6 167 165 6.1 0 6.2 5.7 10/17/2006 19:00:00 5.7 0.3 6.5 4.9 5.5 0.2 6.1 4.9 5.8 0.3 6.5 4.9 172 6 173 165 6.1 0 6.2 6 10/17/2006 19:10:00 4.4 0.6 6.1 3 4.3 0.5 5.7 3 4.6 0.5 6.5 3.4 169 8 167 165 6.2 0 6.5 6 10/17/2006 19:20:00 4.1 0.7 6.5 2.6 4.2 0.6 6.5 3 4.3 0.5 5.7 3 166 8 164 165 6.1 0 6.2 5.7 10/17/2006 19:30:00 4.7 0.7 6.5 3 4.7 0.6 6.5 3 4.8 0.8 6.8 3.4 177 11 166 165 6.1 0 6.2 5.7 10/17/2006 19:40:00 4.9 0.5 6.1 3.4 4.9 0.5 6.1 3.8 5 0.6 6.8 3.4 184 7 182 165 5.9 0.1 6.2 5.7 10/17/2006 19:50:00 5.6 0.4 6.8 4.9 5.5 0.4 6.8 4.9 5.9 0.4 7.6 4.9 179 6 172 165 5.9 0 6.2 5.7 10/17/2006 20:00:00 5.3 0.6 6.5 4.2 5.2 0.5 6.5 4.2 5.5 0.5 6.8 4.2 162 4 162 165 6.1 0 6.2 6 10/17/2006 20:10:00 5.2 0.5 6.5 3.8 5.1 0.5 6.1 3.8 5.3 0.5 6.5 3.8 160 4 163 165 6 0 6.2 5.7 10/17/2006 20:20:00 5.4 0.7 6.8 3.8 5.4 0.7 6.8 3.8 5.5 0.7 7.6 3.8 157 6 152 165 6 0 6.2 5.7 10/17/2006 20:30:00 7.1 0.9 9.1 4.9 7.1 0.9 9.5 4.9 7 0.9 9.1 4.6 162 8 165 165 6 0 6.2 5.5 10/17/2006 20:40:00 8.4 0.5 9.5 6.8 8.2 0.5 9.5 6.8 8.4 0.6 9.9 6.5 164 5 165 165 6.1 0 6.2 5.5 10/17/2006 20:50:00 7.2 0.8 8.8 4.2 7 0.8 8.8 4.6 7.2 0.9 9.1 4.9 163 14 164 165 6.1 0 6.2 5.5 10/17/2006 21:00:00 6.9 0.5 8 5.7 6.8 0.5 8 5.3 7.2 0.4 8.4 5.7 156 4 158 165 6 0 6.2 5.7 10/17/2006 21:10:00 7.3 0.4 8.8 6.1 7.2 0.4 8.4 6.5 7.6 0.4 8.8 6.8 156 3 160 165 5.9 0 6 5.7 10/17/2006 21:20:00 7 0.3 7.6 6.5 6.8 0.3 7.2 6.1 7.2 0.3 8 6.5 154 3 154 165 5.8 0 6 5.7 10/17/2006 21:30:00 7.3 0.3 8 6.1 7.1 0.3 8 6.5 7.6 0.4 8.4 6.5 156 3 162 165 5.9 0 6.2 5.7 10/17/2006 21:40:00 7.7 0.4 8.8 6.8 7.6 0.5 8.8 6.5 7.9 0.4 9.1 6.8 152 3 149 165 6 0 6.2 5.7 10/17/2006 21:50:00 8.6 0.3 9.5 7.6 8.6 0.3 9.1 7.2 8.8 0.4 9.5 7.2 151 2 154 165 6.1 0 6.2 5.7 10/17/2006 22:00:00 8.8 0.5 9.9 7.6 8.7 0.5 9.9 7.6 8.8 0.5 9.9 7.2 151 3 151 165 6.2 0 6.5 6 10/17/2006 22:10:00 9.3 0.5 10.7 8 9.3 0.5 10.7 7.6 9.3 0.6 11.1 6.8 149 4 150 165 6.3 0 6.7 6 10/17/2006 22:20:00 10.3 0.4 11.5 8.8 10.3 0.4 11.5 8.8 10.1 0.5 11.5 8.4 151 3 142 165 6.3 0.1 6.7 6 10/17/2006 22:30:00 11 0.6 12.2 9.5 10.9 0.6 12.2 9.5 10.9 0.7 12.2 8.4 151 3 148 165 6.3 0.1 6.7 5.7 10/17/2006 22:40:00 11.1 0.6 12.2 9.1 11 0.6 12.2 9.1 11.1 0.6 12.6 9.1 151 3 148 165 6.3 0.1 6.7 5.7 10/17/2006 22:50:00 10.9 0.6 13 9.1 10.8 0.6 13 8.8 11 0.8 12.6 8 153 3 147 165 6.2 0.2 6.7 5.7 10/17/2006 23:00:00 10.5 0.5 11.8 8.8 10.4 0.5 11.8 9.1 10.6 0.6 12.2 8.8 153 3 154 165 6.3 0 6.5 5.7 10/17/2006 23:10:00 10.1 0.5 11.1 8.8 10.1 0.5 11.1 8.8 10 0.7 11.5 8 149 4 155 165 6.3 0.1 6.5 5.7 10/17/2006 23:20:00 10.1 0.5 11.1 8.4 10.1 0.5 11.5 8.4 10 0.7 11.5 8.4 150 3 147 165 6.3 0.1 6.7 5.7 10/17/2006 23:30:00 10 0.7 11.5 8.4 10 0.7 11.8 8.4 9.9 0.8 11.8 7.2 149 4 154 165 6.4 0 6.7 5.7 10/17/2006 23:40:00 10.3 0.6 11.5 8.8 10.3 0.6 11.8 8.8 10.2 0.7 11.8 8.4 150 4 143 165 6.4 0.2 6.7 5.7 10/17/2006 23:50:00 10 0.7 11.8 8.4 9.9 0.6 11.8 8.8 10.3 0.7 12.2 8.4 155 4 158 165 6.2 0 6.2 6 10/18/2006 00:00:00 9.9 0.5 11.5 8.4 9.8 0.5 11.5 8.4 10 0.6 11.5 8 155 4 151 165 6.1 0 6.2 5.7 10/18/2006 00:10:00 11.8 1 13.7 9.5 11.6 1 13.7 9.5 11.9 1.1 14.1 8.8 157 4 150 165 5.9 0.1 6.2 5.7 10/18/2006 00:20:00 11.8 0.8 13.7 10.3 11.7 0.7 13.7 9.9 11.9 0.8 14.1 9.5 158 6 162 165 5.8 0 6 5.7 10/18/2006 00:30:00 12.3 0.8 14.5 9.9 12.2 0.8 13.7 9.9 12.5 0.8 14.5 9.9 158 9 157 165 5.9 0 6 5.7 10/18/2006 00:40:00 11.4 0.7 13 9.1 11.3 0.6 12.6 9.1 11.6 0.8 13.3 9.5 156 10 157 165 5.9 0 6.2 5.7 10/18/2006 00:50:00 11.7 0.5 13 10.3 11.6 0.5 13.3 9.9 12 0.6 13.3 9.9 155 4 156 165 5.9 0 6 5.7 10/18/2006 01:00:00 12.2 0.6 13.3 10.7 12.2 0.6 13.3 10.3 12.3 0.7 13.7 10.3 155 3 163 165 5.9 0 6.2 5.7 10/18/2006 01:10:00 10.9 0.8 12.6 8.4 11 0.9 13 8.8 10.9 1 13 8.4 156 5 152 165 6.2 0.1 6.5 5.7 10/18/2006 01:20:00 13.4 1.3 16.4 8.8 13.5 1.3 16.4 9.1 13.1 1.3 16.1 8.4 142 6 142 165 6.4 0 6.7 6.2 10/18/2006 01:30:00 13.8 1.2 17.6 9.5 13.9 1.2 18.3 9.1 13.6 1.2 17.2 9.9 141 6 133 165 6.2 0 6.5 6 10/18/2006 01:40:00 13.8 1.1 16.4 11.1 13.9 1.1 16.8 11.1 13.8 1.1 16.4 10.3 144 5 142 165 6.2 0.1 6.5 5.7 10/18/2006 01:50:00 15.1 1.7 19.5 11.5 15.1 1.7 19.1 11.8 14.9 1.6 19.1 11.8 146 6 148 165 6.3 0.1 6.7 5.7 10/18/2006 02:00:00 15.1 1 17.2 12.2 15.2 1 17.2 12.2 15 1.1 17.2 11.5 143 5 148 165 6.3 0.1 6.7 6 10/18/2006 02:10:00 15.4 1.3 20.6 12.2 15.5 1.3 21 12.2 15.2 1.3 18.7 11.8 142 6 127 165 6.4 0 6.7 6 10/18/2006 02:20:00 16.8 1.6 21 11.8 16.8 1.6 21.4 11.8 16.5 1.8 20.6 12.2 146 7 128 165 6.5 0 6.7 6.2 10/18/2006 02:30:00 14.9 1.3 19.1 11.5 14.9 1.3 18.7 10.7 14.7 1.5 19.1 10.3 148 6 148 165 6.4 0 6.7 6 10/18/2006 02:40:00 15.5 1 17.9 12.6 15.5 1 17.9 12.6 15.4 1 18.3 12.6 148 4 145 165 6.4 0.1 6.7 6 10/18/2006 02:50:00 18.2 2 23.3 13 18.2 2 23.3 12.6 17.7 2.2 22.1 11.8 149 6 150 165 6.2 0.2 6.7 5.7 10/18/2006 03:00:00 14.9 1 17.9 11.8 14.9 1 17.9 12.2 14.7 1.2 17.6 11.5 148 5 156 165 5.7 0.2 6.2 5 10/18/2006 03:10:00 14.6 0.9 16.8 11.8 14.7 0.9 16.8 11.8 14.5 1.2 16.8 11.1 147 5 145 165 5.7 0.2 6 5 10/18/2006 03:20:00 14.8 1.4 19.9 12.2 14.9 1.4 19.9 12.2 14.7 1.5 20.2 10.7 147 7 155 165 5.9 0.2 6.2 5.2 10/18/2006 03:30:00 13.7 1.2 18.7 11.5 13.8 1.2 18.3 11.5 13.5 1.3 17.9 9.9 150 5 162 165 5.8 0.2 6.2 5.2 10/18/2006 03:40:00 13 1.1 16.8 9.9 13 1.1 16.8 10.3 13 1.2 15.6 9.9 148 5 148 165 5.9 0.2 6.2 5.2 10/18/2006 03:50:00 14.4 1.5 17.6 11.1 14.5 1.5 17.6 11.1 14.2 1.6 17.6 9.9 145 5 148 165 6.1 0.3 6.7 5.5 10/18/2006 04:00:00 16 1.5 19.5 11.8 16 1.5 19.9 11.8 15.6 1.5 19.1 11.1 146 5 143 165 6.3 0.2 7 5.7 10/18/2006 04:10:00 16.8 1.5 20.6 13.7 16.8 1.5 20.6 13.7 16.4 1.9 20.6 11.1 148 3 147 165 6.1 0.1 6.2 5.7 10/18/2006 04:20:00 15.4 0.9 17.6 13 15.4 0.9 17.9 12.6 15.2 1.1 17.9 11.8 150 4 150 165 6.2 0.2 6.7 5.7 10/18/2006 04:30:00 16.8 1.3 19.9 13 16.9 1.3 20.2 13 16.6 1.5 21 11.5 147 5 155 165 6.2 0.2 6.7 5.7 10/18/2006 04:40:00 17.1 1.4 21 13 17.1 1.4 21.4 13 17 1.5 20.6 12.6 148 4 149 165 6.1 0 6.2 5.7 10/18/2006 04:50:00 16.6 1.4 19.9 13 16.6 1.4 19.9 13 16.4 1.6 20.2 11.5 146 5 146 165 6.1 0 6.2 5.7 10/18/2006 05:00:00 16.4 1.1 19.5 13.3 16.4 1 19.5 13.3 16.2 1.2 19.9 12.6 144 6 150 165 6.1 0 6.2 6 10/18/2006 05:10:00 16.7 1.2 19.9 13.7 16.8 1.1 19.5 14.1 16.6 1.3 20.2 13 143 5 145 165 6.1 0 6.2 5.7 10/18/2006 05:20:00 17.6 1.5 21.4 12.6 17.6 1.5 21.8 12.2 17.4 1.7 21.8 13 143 6 134 165 6.1 0 6.2 5.7 10/18/2006 05:30:00 16.1 1.3 19.1 11.8 16.1 1.2 19.5 12.2 15.8 1.5 19.5 8.8 145 6 141 165 6.2 0 6.2 5.7 10/18/2006 05:40:00 17.3 1.4 21 12.6 17.4 1.5 21.4 11.8 16.9 1.6 21 11.5 142 7 136 165 6.3 0.1 6.5 6 10/18/2006 05:50:00 20.1 2 25.2 13 20.1 2 24.8 13.3 19.5 2.3 24.4 10.7 140 6 143 165 6.3 0 6.5 6.2 10/18/2006 06:00:00 20.2 2.4 26.3 12.6 20.2 2.4 26 13 19.8 2.7 27.5 14.1 142 8 149 165 6.4 0 6.7 6.2 10/18/2006 06:10:00 20.6 2.3 26 14.1 20.6 2.3 26 14.5 20.2 2.4 25.6 13.7 141 8 124 165 6.6 0 6.7 6 10/18/2006 06:20:00 22 2.1 26.3 17.2 21.9 2.1 26.8 16.8 21.7 2.5 26.8 14.1 142 7 135 165 6.6 0.2 7 6 10/18/2006 06:30:00 20.9 2.3 26 16.1 20.9 2.3 26 15.3 20.4 2.3 25.6 13.7 142 7 145 165 6.8 0.2 7.3 6.2 10/18/2006 06:40:00 22.1 2 26.8 17.6 22.1 2 26.8 17.6 21.9 2.1 27.1 16.8 142 6 132 165 7.1 0.3 7.5 6.5 10/18/2006 06:50:00 20.5 2 27.1 15.3 20.5 2 26.8 14.9 20.3 1.9 25.6 15.3 139 8 143 165 7.3 0.2 7.8 7 10/18/2006 07:00:00 21.3 2.6 27.1 14.9 21.3 2.6 27.1 14.1 20.6 2.6 28.3 14.5 140 7 131 165 7.6 0.1 8 7 10/18/2006 07:10:00 20.3 1.8 25.6 15.3 20.2 1.8 26 15.6 20 1.9 25.6 14.9 144 7 142 165 7.9 0.1 8.3 7.5 10/18/2006 07:20:00 21.1 2.1 26.8 16.4 21 2.1 26.3 16.4 20.5 2.6 26.8 11.8 144 7 145 165 8.1 0 8.5 7.8 10/18/2006 07:30:00 18.6 1.5 21.8 14.1 18.6 1.4 21.4 14.5 18.3 1.6 21.8 13.3 145 5 139 165 8.2 0 8.5 7.8 10/18/2006 07:40:00 15.1 1.2 18.3 11.5 15.1 1.2 18.3 12.2 14.5 1.5 18.3 10.3 146 5 144 165 8.1 0 8.5 7.8 10/18/2006 07:50:00 15.2 1 17.6 12.2 15.2 1 17.6 11.8 14.7 1.3 17.2 9.9 145 5 146 165 8.1 0 8.3 7.8 10/18/2006 08:00:00 13.7 0.8 15.3 11.1 13.7 0.8 15.6 11.1 13.4 1 16.1 10.3 147 4 147 165 8 0.1 8.3 7.8 10/18/2006 08:10:00 13.1 0.8 14.9 11.1 13.1 0.8 14.9 11.5 12.7 1 14.9 9.1 148 4 153 165 7.9 0.1 8.3 7.5 10/18/2006 08:20:00 12.7 0.7 14.5 10.3 12.7 0.7 14.5 10.3 12.4 0.9 14.1 8.8 146 3 146 165 7.8 0.2 8 7.5 10/18/2006 08:30:00 12.1 1 15.3 9.9 12.1 1 15.6 9.9 11.7 1.2 15.3 8.4 143 5 142 165 7.9 0.2 8.3 7.3 10/18/2006 08:40:00 13.2 1 15.3 10.7 13.3 1 15.6 10.7 13 1.1 15.6 9.5 143 5 136 165 7.9 0.1 8.3 7.5 10/18/2006 08:50:00 12.6 1.2 16.1 9.5 12.7 1.2 16.1 9.5 12.3 1.2 16.1 8.4 141 7 140 165 7.9 0.1 8.3 7.5 10/18/2006 09:00:00 12.7 1.3 16.1 9.5 12.8 1.3 16.4 9.5 12.5 1.3 15.6 9.1 142 5 135 165 7.6 0.2 8 7 10/18/2006 09:10:00 12.2 1.5 15.3 8.8 12.3 1.5 15.3 9.1 12.1 1.5 16.1 8.8 145 6 150 165 7.4 0.2 7.8 6.7 10/18/2006 09:20:00 13 1 14.9 9.9 13 1 15.3 10.3 12.9 1.2 15.3 9.1 143 6 145 165 7.6 0.2 7.8 7.3 10/18/2006 09:30:00 13.7 1.2 16.1 10.7 13.8 1.2 16.4 9.9 13.5 1.2 16.8 10.7 141 7 138 165 7.5 0.2 7.8 7 10/18/2006 09:40:00 13.8 1.3 16.8 9.9 13.9 1.3 16.8 10.7 13.6 1.3 16.4 9.1 141 6 132 165 7.4 0.2 7.8 7 10/18/2006 09:50:00 12.9 1.1 16.8 10.3 13 1.1 16.8 10.3 12.7 1.2 16.4 9.1 139 7 156 165 7.4 0.2 7.8 7 10/18/2006 10:00:00 11.7 1 14.5 9.5 11.7 1 14.5 9.1 11.3 1.2 14.1 7.6 134 7 139 165 7.3 0.3 7.8 7 10/18/2006 10:10:00 10.8 1.1 13.7 8 10.9 1.1 13.7 8.4 10.6 1.2 13.3 7.6 128 7 123 165 7.4 0.2 7.8 7 10/18/2006 10:20:00 11.3 1 14.5 8.8 11.5 1 14.5 8.8 11.1 1.1 13.7 8.4 124 5 126 165 7.4 0.2 7.8 7 10/18/2006 10:30:00 11.2 1.3 14.1 8.4 11.4 1.3 14.5 8 11.1 1.4 15.3 8.4 125 6 118 165 7.6 0.2 7.8 6.7 10/18/2006 10:40:00 11.7 1.5 15.3 8 11.8 1.5 15.3 8 11.2 1.6 15.3 8 120 9 115 165 7.6 0.2 7.8 7 10/18/2006 10:50:00 10.4 1.3 15.3 7.6 10.4 1.3 15.6 7.2 10.1 1.5 14.9 6.5 132 8 123 165 7.6 0.2 8 7.3 10/18/2006 11:00:00 10.3 1 13 6.8 10.3 1.1 13 6.5 10 1 12.6 6.8 130 6 117 165 7.7 0.2 8 7.3 10/18/2006 11:10:00 11.8 1.6 15.3 7.6 11.9 1.6 15.6 7.2 11.6 1.7 16.1 6.5 130 6 122 165 7.7 0.2 8 7.3 10/18/2006 11:20:00 11.2 1.1 13.7 7.6 11.3 1.1 14.1 8.4 10.8 1.2 14.1 7.6 130 8 126 165 7.8 0.2 8 7.5 10/18/2006 11:30:00 10 0.9 11.8 7.2 10.2 0.9 12.2 7.6 9.8 1 12.2 6.5 125 7 121 165 7.9 0.1 8.3 7.5 10/18/2006 11:40:00 9.7 1.1 12.2 6.5 9.9 1.2 12.2 6.5 9.4 1.1 11.8 6.5 120 6 128 165 7.9 0.1 8.3 7.5 10/18/2006 11:50:00 9.1 1 12.2 6.5 9.2 1.1 11.8 6.1 8.9 1.2 11.5 6.1 122 5 119 165 8 0.1 8.3 7.5 10/18/2006 12:00:00 7.1 1 9.5 4.6 7.1 1 9.9 4.6 6.9 1 9.5 4.2 120 7 128 165 8 0 8.3 7.8 10/18/2006 12:10:00 6.1 1 8.4 3.4 6.3 1 8.8 3.4 5.8 1 8 3 112 8 114 165 8.1 0.1 8.5 7.5 10/18/2006 12:20:00 6.2 1 8.4 3.4 6.3 1 8.8 3.4 5.9 1 8.4 3.4 103 6 108 165 8.2 0.1 8.5 7.8 10/18/2006 12:30:00 4.6 0.7 6.5 2.6 4.8 0.8 6.5 3 4.5 0.7 6.1 3 86 8 79 165 8.3 0 8.5 8.3 10/18/2006 12:40:00 4.5 0.6 6.1 3 4.7 0.6 6.1 3.4 4.6 0.6 6.1 3.4 83 8 87 165 8.2 0.1 8.5 8 10/18/2006 12:50:00 4.6 0.9 6.8 2.6 4.8 1 7.2 2.6 4.8 0.8 6.8 3 80 9 85 165 8.3 0.1 8.5 8 10/18/2006 13:00:00 2.8 0.7 4.6 1.1 2.9 0.7 4.9 1.1 2.9 0.8 4.9 1.5 55 16 62 165 8.5 0.1 8.8 8.3 10/18/2006 13:10:00 4.3 0.9 6.1 2.3 4.2 1 6.5 2.3 4.3 1 6.8 2.3 32 15 22 165 8.4 0 8.8 8.3 10/18/2006 13:20:00 5.7 0.7 7.6 4.2 5.5 0.8 7.6 3.4 5.7 0.8 8 3.8 24 9 22 165 8.3 0.1 8.5 8 10/18/2006 13:30:00 6.2 0.7 8 4.2 6.1 0.8 7.6 3 6.2 0.8 8.4 4.2 27 8 36 165 8.4 0.1 8.8 8 10/18/2006 13:40:00 6.7 1 9.1 4.2 6.5 1.1 9.1 3.8 6.8 0.9 9.5 4.9 23 9 16 165 8.4 0 8.5 8 10/18/2006 13:50:00 6.6 0.9 8.4 4.2 5.9 1.1 8.4 2.6 6.5 0.9 8.8 4.6 16 9 22 165 8.4 0.1 8.8 8 10/18/2006 14:00:00 6.9 0.7 8.8 4.9 5.3 1 8 3 6.7 0.7 8.4 4.9 8 7 7 165 8.4 0 8.8 8 10/18/2006 14:10:00 6.8 0.7 9.5 4.6 5.7 1.1 8.8 2.6 6.8 0.8 9.9 4.6 12 7 14 165 8.4 0.1 8.8 8 10/18/2006 14:20:00 6.3 0.8 9.5 4.2 4.6 1.1 8.4 1.9 6.2 1 9.1 4.2 6 8 8 165 8.4 0.1 8.5 8 10/18/2006 14:30:00 6.6 1.1 9.5 4.2 5.2 1.1 9.1 2.3 6.3 1.1 9.5 3.8 3 10 7 165 8.4 0.1 8.8 8.3 10/18/2006 14:40:00 6.4 1 10.3 4.2 5.5 1.2 9.9 2.3 6.4 1 9.5 3 352 11 356 165 8.4 0.1 8.5 8 10/18/2006 14:50:00 7.2 1.1 10.3 4.6 7.2 1.1 9.9 4.2 6.7 1 10.3 4.6 336 11 336 165 8.3 0 8.5 8 10/18/2006 15:00:00 8.8 1 11.5 5.7 8.7 1.1 11.1 4.9 8.2 1 11.1 5.3 331 10 329 165 8.1 0 8.5 7.8 10/18/2006 15:10:00 10.3 1.6 16.1 5.7 10.2 1.6 16.4 5.7 9.7 1.9 15.3 4.9 335 10 325 165 8 0.1 8.3 7.5 10/18/2006 15:20:00 10.2 1.5 14.1 7.2 9.6 1.6 13.7 4.9 9.5 1.6 14.1 6.1 339 13 332 165 8 0.1 8.3 7.5 10/18/2006 15:30:00 11.7 1.6 14.5 7.6 11.5 1.9 14.5 5.3 11.2 1.6 14.5 6.5 342 10 331 165 7.9 0.2 8.3 7.5 10/18/2006 15:40:00 12.1 2.1 15.6 5.3 11.9 2.2 15.6 5.3 11.5 2 15.6 5.7 340 10 335 165 7.8 0.2 8 7.5 10/18/2006 15:50:00 13.2 1.7 17.2 9.5 12.7 2.1 17.9 7.6 12.2 1.8 16.8 7.2 346 9 348 165 7.6 0.2 8 7.3 10/18/2006 16:00:00 12.5 1.9 16.1 6.5 12.5 2.3 16.4 6.1 11.5 2 15.3 6.5 344 7 337 165 7.7 0.2 8 7.3 10/18/2006 16:10:00 11.7 1.3 15.6 8.4 11.1 1.7 16.1 5.7 11.5 1.4 15.3 8 347 8 355 165 7.8 0.2 8 7.3 10/18/2006 16:20:00 11.5 1.7 15.3 7.2 11.2 1.8 15.3 6.5 11.6 1.7 15.6 7.2 344 8 347 165 7.7 0.2 8 7.3 10/18/2006 16:30:00 10.3 1.7 14.9 4.9 10.1 1.5 14.9 5.3 10.2 1.7 14.9 6.1 341 10 4 165 7.6 0.2 8 7.3 10/18/2006 16:40:00 11.4 1.7 15.3 6.8 11.4 1.9 16.8 6.8 11.3 1.8 16.1 6.8 341 7 344 165 7.6 0.2 8 7 10/18/2006 16:50:00 9.6 1.3 12.6 6.5 8.9 1.3 12.6 5.7 9.5 1.3 12.6 6.5 345 10 356 165 7.6 0.3 8 7.3 10/18/2006 17:00:00 9.4 1.2 13 6.8 9.2 1.4 13 5.7 9.1 1.3 13 5.3 332 16 331 165 7.6 0.2 8 7 10/18/2006 17:10:00 9.3 1.5 12.6 5.3 9 1.5 12.2 5.3 8.6 1.6 13 5.3 327 17 350 165 7.6 0 7.8 7 10/18/2006 17:20:00 9.1 1.1 11.8 6.5 9 1.1 11.8 6.1 8.7 1.3 11.5 5.3 326 13 304 165 7.5 0 7.8 7 10/18/2006 17:30:00 9.6 1.3 13.3 6.5 9.4 1.3 13 6.1 9 1.3 12.6 5.7 324 11 320 165 7.6 0 7.8 7 10/18/2006 17:40:00 9.5 1.1 13 6.8 9.4 1.2 12.6 6.8 9.2 1.3 13.3 5.7 330 13 318 165 7.8 0 8 7 10/18/2006 17:50:00 9.3 1.7 14.9 5.7 9 1.7 14.1 5.7 8.4 1.2 11.5 5.3 314 10 304 165 7.7 0 8 7 10/18/2006 18:00:00 12.2 1.2 15.6 8.8 12 1.1 15.6 9.1 10.7 1.3 14.1 7.6 308 9 325 165 7.7 0 8 7 10/18/2006 18:10:00 13.1 1.3 16.1 9.1 13 1.3 15.6 8.8 12.3 1.3 16.8 9.1 314 8 315 165 7.8 0 8 7.3 10/18/2006 18:20:00 13.4 1.2 16.8 9.9 13.3 1.2 16.8 9.9 12.4 1.1 16.1 8.8 315 8 319 165 7.8 0 8 7.3 10/18/2006 18:30:00 14.6 1.1 17.6 11.5 14.5 1.1 17.2 11.5 13.7 1.5 16.4 9.5 316 7 315 165 7.8 0 8 7.5 10/18/2006 18:40:00 14.3 1.1 17.6 11.5 14.2 1.2 17.2 11.5 13.8 1.2 16.8 10.7 318 5 313 165 7.8 0 8 7.5 10/18/2006 18:50:00 13.8 1 16.8 10.7 13.7 1.1 16.8 10.7 13.7 1.1 17.2 9.9 319 8 322 165 7.8 0 8 7.3 10/18/2006 19:00:00 14.1 1 17.6 11.1 14 1 17.6 11.1 13.5 1.2 16.4 9.5 316 7 309 165 7.8 0 8 7.3 10/18/2006 19:10:00 14.4 1.2 17.2 10.3 14.3 1.2 16.8 10.3 13.9 1.2 17.2 9.9 316 8 321 165 7.8 0 8 7.3 10/18/2006 19:20:00 12.3 1.6 17.2 7.2 12.2 1.6 16.4 7.6 11.3 1.6 15.3 6.8 314 12 302 165 7.8 0 8 7.3 10/18/2006 19:30:00 9.7 1.2 13 6.1 9.5 1.3 13 5.3 8.1 1 11.1 5.7 307 8 306 165 7.7 0 7.8 7.3 10/18/2006 19:40:00 10.4 1.6 14.5 5.3 10.3 1.5 14.5 5.3 9.1 1.5 12.6 5.3 309 8 320 165 7.6 0 7.8 7 10/18/2006 19:50:00 12 1.5 14.9 7.2 11.9 1.4 14.9 7.2 10.5 1.7 14.9 5.3 310 8 310 165 7.4 0 7.8 7.3 10/18/2006 20:00:00 12.5 1.5 17.2 7.2 12.4 1.4 17.2 7.6 11.1 1.7 15.3 6.1 313 9 316 165 7.4 0 7.5 7.3 10/18/2006 20:10:00 10.9 1.5 15.3 5.7 10.5 1.6 16.1 5.7 10.5 1.7 16.8 5.7 336 15 355 165 7.4 0 7.5 7.3 10/18/2006 20:20:00 9.2 1.2 13 5.3 9 1.2 13 4.9 8 1.2 12.2 4.9 311 11 332 165 7.5 0 7.8 7.3 10/18/2006 20:30:00 10.8 1.2 13.3 7.2 10.6 1.2 13.7 7.2 8.8 1.3 12.2 5.3 307 6 307 165 7.4 0 7.5 7.3 10/18/2006 20:40:00 9.4 1.4 13.7 5.7 9.3 1.4 13.7 5.3 8.8 1.4 12.6 6.1 318 9 315 165 7.4 0 7.8 7.3 10/18/2006 20:50:00 9.8 1.1 12.2 7.2 9.7 1.1 12.2 6.8 8.9 1.2 12.2 5.7 314 7 320 165 7.4 0 7.8 7.3 10/18/2006 21:00:00 10.6 1.3 14.1 7.2 10.4 1.3 14.1 7.6 10.3 1.3 14.5 7.6 322 7 328 165 7.4 0 7.5 7.3 10/18/2006 21:10:00 9.8 1 13 6.8 9.6 1 13 7.2 9.5 0.9 12.2 6.8 322 10 308 165 7.4 0 7.5 7 10/18/2006 21:20:00 10.1 1.4 13.3 6.8 9.8 1.4 13 6.5 9.3 1.5 13.3 6.1 316 9 320 165 7.4 0 7.5 7 10/18/2006 21:30:00 10.3 1.1 14.5 7.6 10.1 1.1 14.1 7.6 9.8 1 11.8 7.6 317 7 297 165 7.3 0 7.5 7 10/18/2006 21:40:00 11.7 1 14.5 8.4 11.5 1 14.1 8 10.9 1.1 13 7.6 314 7 313 165 7.3 0 7.5 6.7 10/18/2006 21:50:00 13 1.1 15.3 9.9 12.8 1.2 14.9 9.5 11.5 1.4 14.5 8 310 5 305 165 7.4 0.1 7.8 7 10/18/2006 22:00:00 13.3 1.2 16.1 10.7 13.1 1.2 16.1 10.3 12 1.6 15.3 7.6 312 5 313 165 7.7 0 8 7.3 10/18/2006 22:10:00 14.2 1.3 17.2 10.3 14 1.3 17.2 9.9 13.1 1.5 16.4 9.5 313 5 314 165 7.5 0.1 7.8 7 10/18/2006 22:20:00 12.5 1.6 15.6 8.8 12.4 1.5 15.6 8.8 11.4 2 15.3 5.7 315 6 310 165 7.3 0.2 7.8 7 10/18/2006 22:30:00 6.6 2.3 11.8 1.1 6.6 2.4 11.8 1.1 4.9 2.3 11.5 0.4 312 17 315 165 7.2 0.2 7.5 6.5 10/18/2006 22:40:00 3.7 1.7 7.2 0.4 3.7 1.7 7.2 0.4 3.3 1.3 6.1 0.4 326 47 336 165 7.2 0.2 7.5 6.5 10/18/2006 22:50:00 4.1 2 8.8 0.4 4.2 1.9 9.1 0.4 3.5 1.7 8 0.7 286 17 291 165 7.1 0.2 7.5 6.2 10/18/2006 23:00:00 4.4 1.2 7.6 1.9 4.6 1.1 7.6 1.9 4 1.1 7.2 1.9 287 15 307 165 7.3 0.2 7.8 7 10/18/2006 23:10:00 4.9 0.8 7.2 2.6 4.9 0.8 7.2 2.6 4.4 0.8 6.8 2.6 292 11 286 165 7.4 0.1 7.8 7 10/18/2006 23:20:00 4.6 0.9 7.2 2.3 4.5 0.9 7.2 2.6 4.2 0.8 6.5 2.3 303 12 309 165 7.3 0.2 7.8 6.7 10/18/2006 23:30:00 3.6 0.9 6.1 1.5 3.5 0.9 6.1 1.5 3.1 0.8 6.1 1.5 303 11 297 165 7.2 0.2 7.5 6.2 10/18/2006 23:40:00 3.1 0.7 4.6 0.7 3.4 0.7 4.9 1.1 3.5 0.7 4.9 1.5 250 10 249 165 6.8 0 7.3 6.5 10/18/2006 23:50:00 4.4 0.8 6.1 2.3 4.6 0.7 6.1 3 4.7 0.6 6.5 3 275 7 278 165 7.1 0 7.3 6.7 10/19/2006 00:00:00 4.5 1 6.1 2.3 5.1 0.7 6.5 3.4 4.9 0.8 6.5 3.4 269 3 273 165 7.1 0 7.5 7 10/19/2006 00:10:00 3.6 0.8 5.3 1.9 4.4 0.5 5.7 3.4 4.4 0.5 5.7 3 264 6 271 165 7.2 0.1 7.5 6.7 10/19/2006 00:20:00 3.4 0.6 4.6 2.3 4.2 0.4 5.3 3.4 4.1 0.4 4.9 2.6 261 5 265 165 7.2 0 7.5 7 10/19/2006 00:30:00 3.3 0.6 4.9 1.9 4 0.4 4.9 3 3.9 0.4 4.9 3 260 6 252 165 7.3 0 7.5 7 10/19/2006 00:40:00 3.1 0.7 4.6 1.1 3.5 0.6 5.3 2.3 3.7 0.5 4.9 2.6 268 6 272 165 7.4 0 7.8 7.3 10/19/2006 00:50:00 4.2 0.9 5.7 1.9 4.8 0.5 5.7 3.4 4.8 0.5 5.7 3.4 270 5 277 165 7.4 0 7.8 7.3 10/19/2006 01:00:00 5 0.4 5.7 3 5.2 0.3 5.7 4.2 5.2 0.4 6.1 4.2 278 5 274 165 7.4 0 7.5 7.3 10/19/2006 01:10:00 3.4 0.6 5.3 1.9 3.6 0.7 5.3 2.6 3.1 0.8 4.9 1.5 286 13 276 165 7.2 0.2 7.5 6.7 10/19/2006 01:20:00 3.6 0.5 4.9 1.9 3.6 0.5 5.3 2.3 3.2 0.7 4.9 1.9 287 11 282 165 6.8 0.1 7.3 6.7 10/19/2006 01:30:00 2.4 1.1 4.9 0.4 2.6 1.1 4.6 0.4 2.7 0.9 4.9 1.1 267 15 288 165 7.4 0.1 7.8 7.3 10/19/2006 01:40:00 2.7 1 4.9 0.4 2.7 1 4.9 0.7 2.9 1 4.6 1.1 275 14 281 165 7.4 0 7.8 7.3 10/19/2006 01:50:00 5.1 0.6 7.2 3.4 5.2 0.6 6.8 3 4.7 0.7 6.1 3 286 7 292 165 7.1 0 7.5 6.7 10/19/2006 02:00:00 4.8 0.6 6.5 3.4 4.8 0.6 6.5 3 4.4 0.7 6.1 3 285 8 279 165 6.9 0 7.3 6.7 10/19/2006 02:10:00 5 0.5 6.5 3.8 5.1 0.5 6.5 3.8 4.1 0.6 6.1 2.6 292 7 281 165 6.9 0 7.3 6.7 10/19/2006 02:20:00 2.9 1.4 5.7 0.4 3.1 1.3 5.7 0.4 3.1 1.1 5.3 1.1 261 24 289 165 6.6 0.1 7 6.2 10/19/2006 02:30:00 4 0.5 4.9 2.3 4.1 0.5 4.9 2.6 3.7 0.7 5.3 1.9 286 6 285 165 6.8 0.2 7.3 6.2 10/19/2006 02:40:00 3.9 0.4 4.9 3 3.9 0.4 4.9 3 3.3 0.7 4.9 1.9 292 6 286 165 7.1 0 7.3 6.7 10/19/2006 02:50:00 3.8 0.4 4.9 3 3.9 0.4 4.9 3 3.9 0.4 4.9 3 277 4 270 165 7.3 0 7.5 7 10/19/2006 03:00:00 3.4 0.6 4.6 1.5 3.7 0.5 4.6 2.3 3.8 0.5 4.6 2.6 269 13 275 165 7.2 0 7.5 6.7 10/19/2006 03:10:00 2.2 0.7 3.4 0.4 2.6 0.8 3.8 0.7 2.7 0.6 3.8 1.1 252 5 251 165 7.2 0 7.5 7 10/19/2006 03:20:00 2.4 0.5 3.8 0.7 2.4 0.5 3.4 1.1 2.6 0.4 3.4 1.5 251 4 246 165 7.4 0.1 7.8 7 10/19/2006 03:30:00 2.2 0.7 3.4 0.7 2.1 0.7 3.4 0.7 2.4 0.6 3.4 1.1 240 5 247 165 7.4 0 7.8 7 10/19/2006 03:40:00 1.2 0.6 2.6 0.4 1.1 0.5 2.6 0.4 1.4 0.4 2.3 0.4 251 17 228 165 7.6 0 8 7.3 10/19/2006 03:50:00 1.6 0.6 3 0.4 1.5 0.6 3 0.4 1.6 0.5 3 0.4 287 6 281 165 7.5 0.2 7.8 7 10/19/2006 04:00:00 2.2 0.8 4.2 0.7 2.4 0.8 4.6 1.1 2.6 0.6 4.2 1.1 268 10 268 165 7.3 0.1 7.5 7 10/19/2006 04:10:00 3.7 0.6 5.3 2.3 4.9 0.5 6.1 3.4 4.5 0.4 5.7 3.4 269 5 277 165 7.1 0 7.5 6.7 10/19/2006 04:20:00 5.3 0.7 6.5 3 5.6 0.5 6.5 4.2 5.5 0.5 6.5 3.8 274 4 275 165 7.4 0.1 8 7 10/19/2006 04:30:00 5.4 0.4 6.5 3.8 5.5 0.3 6.5 4.6 5.4 0.4 6.5 4.2 279 6 276 165 7.6 0.1 8 7 10/19/2006 04:40:00 5.4 0.7 6.5 3 5.8 0.5 6.8 4.6 5.7 0.5 6.8 4.2 273 6 276 165 7.4 0.1 7.5 7 10/19/2006 04:50:00 3.8 1 5.7 1.5 4.1 1.1 6.1 1.5 3.8 1.1 5.7 1.5 284 16 276 165 7.1 0.1 7.5 6.5 10/19/2006 05:00:00 2.7 0.4 3.4 1.5 2.7 0.4 3.4 1.9 2.4 0.4 3.4 1.1 300 17 285 165 6.6 0 7.3 6.2 10/19/2006 05:10:00 3 0.4 3.8 1.9 3 0.4 3.8 2.3 3.1 0.4 4.2 2.3 282 6 292 165 7.1 0 7.3 6.7 10/19/2006 05:20:00 3.9 0.3 4.6 3 3.9 0.3 4.6 3 3.5 0.5 4.6 2.3 293 5 300 165 7.4 0 7.5 7.3 10/19/2006 05:30:00 2.9 0.5 4.2 1.9 3 0.5 4.6 1.9 3.2 0.4 4.6 2.3 277 5 277 165 7.4 0 7.5 7.3 10/19/2006 05:40:00 2.8 0.3 3.4 1.9 3 0.2 3.8 2.3 3.2 0.2 3.8 2.6 270 5 270 165 7.4 0 7.8 7.5 10/19/2006 05:50:00 2.2 0.5 3.4 1.1 2.2 0.6 3.4 1.1 2.5 0.5 3.8 1.1 276 5 268 165 7.6 0 7.8 7.3 10/19/2006 06:00:00 1.1 0.4 1.9 0.4 1.1 0.3 1.9 0.4 1.6 0.3 2.3 1.1 222 41 284 165 7.4 0.1 8 7.3 10/19/2006 06:10:00 1.6 0.6 3 0.4 1.3 0.6 2.6 0.4 1.7 0.4 2.6 1.1 180 9 193 165 7.3 0 7.5 7.3 10/19/2006 06:20:00 2.9 0.7 4.2 1.5 2.8 0.7 4.2 1.5 2.8 0.7 4.2 1.5 189 7 190 165 7.3 0 7.5 7 10/19/2006 06:30:00 2.7 0.6 3.8 1.1 2.5 0.6 3.8 1.1 2.6 0.5 3.8 1.5 173 12 190 165 7.3 0 7.5 7 10/19/2006 06:40:00 2.8 0.4 3.4 1.5 2.7 0.4 3.4 1.5 2.8 0.4 3.8 1.9 188 11 176 165 7 0 7.3 6.7 10/19/2006 06:50:00 2.6 0.5 3.8 1.1 2.5 0.6 3.8 1.1 2.8 0.5 3.8 1.5 182 9 188 165 7.3 0 7.5 7 10/19/2006 07:00:00 2.2 0.6 3.4 0.4 2.1 0.6 3 0.4 2.3 0.4 3.4 1.5 195 18 207 165 7.1 0 7.3 7 10/19/2006 07:10:00 2.6 1 3.8 0.4 2.5 1 4.2 0.4 2.9 0.7 4.2 0.7 187 19 205 165 7.1 0.1 7.5 6.2 10/19/2006 07:20:00 2 0.8 3.8 0.4 1.9 0.9 3.8 0.4 2 0.6 4.2 0.7 214 23 240 165 6.7 0.1 7.3 6.2 10/19/2006 07:30:00 2.5 0.4 3.4 1.1 2.4 0.5 3.4 0.7 2.3 0.5 3.4 1.1 221 12 225 165 7.2 0 7.3 6.7 10/19/2006 07:40:00 2.1 0.5 3.8 0.4 2.1 0.5 3.8 0.4 2.3 0.4 3.8 1.1 187 19 182 165 6.9 0.2 7.3 6.2 10/19/2006 07:50:00 1.5 1 3.8 0.4 1.5 1 3.8 0.4 1.3 0.9 4.2 0.4 195 28 218 165 6.6 0 7 6 10/19/2006 08:00:00 3.6 0.7 4.9 1.5 3.6 0.7 4.9 1.5 3.5 0.7 4.9 1.9 203 11 212 165 6.6 0 7 6 10/19/2006 08:10:00 4 0.3 4.9 3.4 4.1 0.3 4.9 3.4 4.3 0.3 4.9 3.4 206 3 211 165 6.5 0 6.7 6 10/19/2006 08:20:00 4.2 0.5 5.3 2.3 4.3 0.5 5.3 2.3 4.2 0.5 5.3 2.3 214 4 213 165 6.2 0.1 6.7 5.7 10/19/2006 08:30:00 4.4 0.4 5.3 3 4.5 0.4 5.3 3 4.5 0.4 5.7 3 209 3 210 165 6.3 0.1 6.5 5.7 10/19/2006 08:40:00 3.8 0.6 5.3 1.5 3.7 0.6 5.3 1.9 3.7 0.5 5.3 2.3 189 10 183 165 6.2 0.1 6.2 5.7 10/19/2006 08:50:00 5.2 0.8 7.6 2.6 5.1 0.8 7.6 2.3 5.1 0.9 7.6 2.6 198 8 186 165 6.6 0.1 7 5.7 10/19/2006 09:00:00 4.3 0.8 6.1 2.6 4.2 0.8 6.1 2.6 4.4 0.7 6.5 2.6 193 8 206 165 7 0.2 7.5 6.2 10/19/2006 09:10:00 5.1 0.6 6.8 3.4 5.1 0.6 6.1 3.4 5.1 0.7 7.2 3 197 11 190 165 7.6 0.1 8 7 10/19/2006 09:20:00 4.5 0.9 6.8 1.5 4.4 0.9 6.5 1.1 4.8 1 7.2 1.5 168 18 172 165 7.9 0.1 8.3 7.3 10/19/2006 09:30:00 4.2 1.2 7.2 1.1 4.1 1.3 7.6 0.4 4 1.2 7.2 0.7 187 21 180 165 7.8 0.1 8.3 7.3 10/19/2006 09:40:00 3.1 1.3 7.2 0.4 3 1.3 6.8 0.4 3.2 1.2 7.2 0.7 195 17 165 165 7.4 0.2 8.3 6.7 10/19/2006 09:50:00 3.2 1 6.1 1.1 3 1 5.7 0.7 3.3 0.9 6.5 1.9 176 15 175 165 8 0.4 8.5 7.3 10/19/2006 10:00:00 4.7 1.7 7.6 1.1 4.6 1.7 7.6 0.7 4.8 1.6 8 1.5 183 16 204 165 8.5 0 8.8 8.3 10/19/2006 10:10:00 5.7 0.8 8.4 3.8 5.6 0.8 8 3.8 5.8 1 8.8 3.4 193 13 201 165 8.3 0.2 8.8 8 10/19/2006 10:20:00 7.5 1.2 9.9 4.2 7.5 1.2 9.9 4.2 7.4 1.2 10.3 4.2 203 9 197 165 8.2 0 8.8 8 10/19/2006 10:30:00 8 1.2 11.1 4.9 8 1.2 11.1 4.9 8.2 1.2 11.1 5.3 197 8 189 165 8.3 0 8.5 8 10/19/2006 10:40:00 7.4 0.9 9.5 4.9 7.4 0.9 9.5 5.3 7.7 0.8 9.5 4.9 198 7 202 165 8.2 0 8.5 8 10/19/2006 10:50:00 9.3 1 11.5 6.5 9.4 1 11.5 6.5 9.2 1 11.5 6.5 199 6 200 165 8.1 0 8.5 8 10/19/2006 11:00:00 8 0.9 9.9 4.6 7.9 0.9 9.9 4.6 8.1 0.8 9.9 5.7 195 5 196 165 8.3 0 8.5 8 10/19/2006 11:10:00 5.9 1 8 3 5.7 1 8.4 3 5.9 1 8 3.8 186 9 196 165 7.9 0.3 8.5 7.5 10/19/2006 11:20:00 6.2 0.8 8.4 4.6 6 0.8 8 4.2 6.3 0.8 8.8 4.2 177 9 182 165 7.9 0.3 8.5 7.5 10/19/2006 11:30:00 5.7 0.9 8 3.4 5.5 0.9 7.6 3.4 5.8 0.9 8 3.8 172 11 173 165 8 0.1 8.5 7.5 10/19/2006 11:40:00 5 1 8 3 4.9 1 8 3 5.2 1 8 2.6 176 12 168 165 8.5 0.1 9 8.3 10/19/2006 11:50:00 5.7 1.7 10.3 2.3 5.4 1.7 9.5 2.3 5.8 1.8 9.1 3 172 15 176 165 9.2 0.4 10.1 8.8 10/19/2006 12:00:00 6.8 1 9.5 4.6 6.6 1 9.9 4.2 6.8 1 9.5 4.6 172 10 183 165 9.7 0 9.8 9.6 10/19/2006 12:10:00 7.3 0.8 9.9 5.3 7 0.8 9.5 5.3 7.7 0.8 9.9 5.7 175 9 173 165 9.8 0 10.6 9.6 10/19/2006 12:20:00 8.1 1.1 10.7 5.7 7.8 1 10.3 5.7 8.3 1.1 10.7 5.7 177 9 183 165 9.8 0 10.3 9.6 10/19/2006 12:30:00 8.2 0.9 10.7 5.7 7.9 0.9 10.3 5.3 8.5 0.8 10.7 6.5 178 9 175 165 9.7 0.1 9.8 9.3 10/19/2006 12:40:00 9.3 1 11.8 6.5 9 1 11.8 7.2 9.5 1 11.8 6.1 179 7 189 165 9.6 0.2 10.3 9.3 10/19/2006 12:50:00 8.3 1.1 11.1 5.3 8.2 1.1 11.1 5.3 8.6 1 11.8 6.5 180 9 189 165 10.1 0 10.3 9.8 10/19/2006 13:00:00 9 0.8 11.5 6.5 8.8 0.8 11.1 6.5 9.4 0.9 11.8 6.1 177 8 176 165 10.1 0 10.6 9.8 10/19/2006 13:10:00 9.3 1 11.8 6.8 9.1 0.9 11.5 6.5 9.7 1 12.6 7.2 177 8 180 165 9.8 0.2 10.3 9.3 10/19/2006 13:20:00 9.2 1.3 13 6.1 9 1.3 13 6.1 9.6 1.3 13.3 6.5 179 9 182 165 10.2 0.2 10.9 9.8 10/19/2006 13:30:00 9.1 1.2 11.8 6.5 9 1.2 12.2 6.1 9.3 1.3 13.3 6.5 185 9 190 165 10.2 0.1 10.6 9.8 10/19/2006 13:40:00 8.9 1 12.2 6.5 8.7 1 11.5 6.1 9.4 1 12.2 7.2 178 8 179 165 9.6 0.4 10.6 9 10/19/2006 13:50:00 8.2 0.9 10.3 5.7 7.9 0.9 9.9 5.7 8.4 1 10.7 5.7 178 9 192 165 8.9 0.4 9.6 8 10/19/2006 14:00:00 7.6 0.8 9.5 5.3 7.2 0.7 8.8 4.9 7.8 0.8 9.5 5.7 170 12 172 165 7.8 0 8.3 7.5 10/19/2006 14:10:00 6.3 0.5 7.2 4.6 5.9 0.5 6.8 4.2 6.5 0.5 7.6 4.9 170 5 169 165 7.7 0 8 7.5 10/19/2006 14:20:00 5.8 0.6 6.8 4.2 5.5 0.6 6.5 3.8 6 0.6 7.2 4.6 176 11 169 165 7.4 0 7.8 7 10/19/2006 14:30:00 4.3 0.6 6.1 3 4 0.6 5.7 2.6 4.4 0.5 5.7 3 178 6 187 165 7.4 0 7.5 7 10/19/2006 14:40:00 4.2 0.5 5.3 3 3.9 0.5 5.3 2.6 4.3 0.5 6.1 3 176 7 158 165 7.7 0.2 8.5 7.3 10/19/2006 14:50:00 5.8 0.9 8 3.4 5.6 0.9 8 3.4 6 0.8 8.4 4.6 164 12 165 165 8.4 0.1 8.8 8.3 10/19/2006 15:00:00 7.4 0.5 8.4 6.1 7.2 0.5 8.4 6.1 7.6 0.5 8.8 6.1 160 6 154 165 8.6 0.2 9 8.3 10/19/2006 15:10:00 6.3 0.5 8 4.6 6.2 0.5 7.6 4.6 6.5 0.5 7.6 4.6 166 7 183 165 9.1 0.2 9.6 8.8 10/19/2006 15:20:00 5.6 0.6 7.2 3.4 5.5 0.6 7.2 3 5.8 0.6 7.6 3.4 166 14 170 165 9.1 0.3 9.8 8.8 10/19/2006 15:30:00 5.7 0.9 8 3.8 5.5 0.9 7.6 3.8 6 0.8 7.6 4.2 166 9 167 165 9.3 0.2 9.6 8.8 10/19/2006 15:40:00 5.2 0.8 8 3.4 5.1 0.8 8 3 5.5 0.7 7.6 3.4 166 13 193 165 9.6 0.1 9.8 9.3 10/19/2006 15:50:00 5.6 1 8.4 3 5.5 1 8.4 3 5.6 1 8.8 3.4 170 11 180 165 9.6 0 9.8 9.3 10/19/2006 16:00:00 6.3 1 8.8 3.4 6.2 1 8.8 3.4 6.5 1.1 8.8 3.4 180 13 165 165 9.6 0.1 9.8 9.3 10/19/2006 16:10:00 7 1.2 11.1 4.2 7 1.2 10.7 4.6 7 1.1 11.1 4.6 189 14 177 165 9.5 0 9.6 9.3 10/19/2006 16:20:00 7.5 1.2 10.3 4.2 7.5 1.1 10.7 4.9 7.7 1.3 11.5 4.6 192 12 192 165 9.3 0 9.6 9 10/19/2006 16:30:00 7.1 1.1 9.9 3.8 7 1.1 9.9 3.4 7.3 1.1 10.3 4.6 190 12 196 165 9.2 0 9.3 9 10/19/2006 16:40:00 7 1 11.8 3.8 6.9 1 11.5 3.8 7 0.9 9.5 3.8 192 10 204 165 9 0 9.3 9 10/19/2006 16:50:00 7.8 1.2 10.7 4.9 7.8 1.2 11.1 4.9 8 1.2 11.5 5.7 191 10 204 165 8.6 0.1 9 7.8 10/19/2006 17:00:00 9.1 0.9 11.1 6.8 9 0.9 11.1 6.1 9.1 1 11.8 5.7 187 7 190 165 8.5 0 8.8 8.3 10/19/2006 17:10:00 8.8 1.1 11.8 5.3 8.7 1 11.5 5.3 8.8 1.1 11.5 6.1 185 8 186 165 8.3 0 8.5 8 10/19/2006 17:20:00 9.2 1.1 11.8 6.5 9.1 1.2 11.8 6.1 9.1 1.1 12.2 6.5 187 7 187 165 8 0.1 8.3 7.5 10/19/2006 17:30:00 8.2 1.1 11.5 5.7 8.2 1.1 11.5 5.7 8.2 1.1 11.1 5.7 189 9 190 165 7.8 0.1 8 7.3 10/19/2006 17:40:00 7.7 0.9 9.9 5.3 7.7 0.9 9.9 4.9 7.7 0.9 9.9 5.7 197 6 201 165 7.7 0 8 7.3 10/19/2006 17:50:00 7 0.9 9.1 4.6 7.1 0.9 9.1 4.2 7 1 9.1 4.6 201 5 208 165 7.6 0.1 7.8 7 10/19/2006 18:00:00 5.7 1.1 8.4 3.4 5.7 1.1 8.4 3.4 5.7 1 8.4 3.4 197 8 190 165 7.6 0 7.8 7 10/19/2006 18:10:00 5 1 7.2 2.6 4.8 1 6.8 2.6 5.2 1.1 7.6 3.4 174 14 165 165 7.3 0 7.8 6.7 10/19/2006 18:20:00 5.9 0.8 7.6 4.2 5.7 0.8 7.2 3.8 6.1 0.8 8 4.2 171 11 176 165 7.1 0 7.3 6.7 10/19/2006 18:30:00 5.7 0.5 7.2 4.2 5.5 0.5 6.8 4.2 5.9 0.6 7.2 4.6 170 7 188 165 6.9 0.1 7.5 6.5 10/19/2006 18:40:00 5.5 0.7 7.2 3.8 5.2 0.7 7.2 3.4 5.5 0.8 7.6 3.4 172 12 175 165 6.7 0.1 7 6.2 10/19/2006 18:50:00 4.4 0.6 6.1 3 4.2 0.6 6.1 2.6 4.3 0.7 6.8 3 176 12 178 165 6.6 0.1 7 6 10/19/2006 19:00:00 4.4 1 6.8 1.9 4.3 1 6.5 1.9 4.5 1 6.8 2.6 184 9 192 165 6.6 0.1 7 6.2 10/19/2006 19:10:00 4.3 1 7.6 2.6 4.1 0.9 6.8 2.6 4.3 0.7 7.6 3 174 9 180 165 6.6 0.1 7 6.2 10/19/2006 19:20:00 5.4 0.7 7.6 3.8 5.2 0.7 7.2 3.4 5.3 0.7 8.4 3.8 184 8 189 165 6.7 0.1 7.3 6.5 10/19/2006 19:30:00 6 0.6 7.6 4.6 6 0.6 7.2 4.6 6.2 0.5 7.6 4.6 193 7 204 165 7.1 0 7.3 6.7 10/19/2006 19:40:00 7.3 0.7 9.5 5.7 7.4 0.8 9.5 5.3 7.5 0.7 9.5 5.7 197 6 195 165 7.1 0.1 7.5 6.7 10/19/2006 19:50:00 6.1 0.8 8.4 4.6 6.2 0.8 8.4 4.6 6.4 0.7 8.4 4.9 201 4 201 165 7.3 0 7.5 7 10/19/2006 20:00:00 5.9 0.8 7.6 4.6 6 0.7 7.6 4.6 6.3 0.6 7.6 4.9 200 3 196 165 7 0.1 7.5 6.7 10/19/2006 20:10:00 7.3 0.5 8.4 6.1 7.2 0.5 8.4 6.1 7.5 0.6 8.8 5.3 194 4 197 165 6.8 0.1 7.3 6.5 10/19/2006 20:20:00 7.6 0.4 8.8 6.5 7.6 0.4 8.4 6.8 7.9 0.4 9.1 6.5 193 2 189 165 6.7 0.2 7.3 6.2 10/19/2006 20:30:00 7.1 0.6 8.8 5.7 7.1 0.6 8.8 5.7 7.5 0.6 8.8 6.1 188 6 203 165 6.7 0.2 7 6.2 10/19/2006 20:40:00 7.2 0.7 8.8 5.7 7 0.6 8.8 5.7 7.1 0.7 8.8 5.7 183 5 185 165 6.6 0 7 6.2 10/19/2006 20:50:00 7.8 0.6 9.5 6.5 7.6 0.6 9.1 5.7 7.9 0.6 9.5 6.1 183 6 180 165 6.6 0 7 6.2 10/19/2006 21:00:00 5.5 1.1 8 3.4 5.5 1 8 3.8 5.6 1 8 2.6 189 8 193 165 6.6 0 7.3 6.2 10/19/2006 21:10:00 5.6 0.9 8.4 3.8 5.5 0.8 7.6 3.8 5.8 0.8 7.6 4.2 186 7 181 165 6.6 0 7 6.2 10/19/2006 21:20:00 6.2 0.7 8.4 4.9 6.2 0.7 7.6 4.9 6.5 0.7 8.4 4.6 184 8 185 165 6.6 0 7 6.2 10/19/2006 21:30:00 6.2 0.9 8.4 4.2 6.1 0.8 8.4 4.2 6.5 0.8 8.4 4.6 188 6 179 165 6.4 0.1 6.7 6 10/19/2006 21:40:00 6.3 0.7 8.4 4.2 6.2 0.7 8.4 4.6 6.4 0.8 8.4 4.2 197 8 205 165 6.4 0 6.7 6 10/19/2006 21:50:00 5.7 0.6 7.6 4.2 5.7 0.6 7.6 4.2 5.8 0.6 7.6 4.2 198 5 205 165 6.3 0 6.7 6 10/19/2006 22:00:00 3.8 0.8 6.1 2.3 3.9 0.8 6.1 2.6 4.1 0.8 6.1 2.6 202 5 203 165 6.1 0.1 6.7 5.5 10/19/2006 22:10:00 4.2 0.7 6.1 2.6 4.2 0.7 6.1 2.6 4.3 0.7 6.1 2.6 196 7 194 165 6.1 0.1 6.2 5.5 10/19/2006 22:20:00 6.7 0.7 8 4.9 6.7 0.7 8 4.9 6.9 0.8 8.4 4.2 190 5 194 165 6.2 0.1 6.5 5.7 10/19/2006 22:30:00 7.4 0.6 8.8 6.1 7.3 0.6 9.1 6.1 7.7 0.6 9.5 6.5 191 4 196 165 6.3 0 6.7 5.7 10/19/2006 22:40:00 7.6 0.8 9.5 5.3 7.6 0.8 9.5 5.7 7.8 0.9 9.9 5.3 197 4 197 165 6.4 0.1 6.7 6 10/19/2006 22:50:00 7.6 0.7 9.1 5.7 7.6 0.7 9.1 6.1 7.9 0.7 9.9 6.5 194 4 195 165 6.4 0 6.7 6 10/19/2006 23:00:00 5.5 0.6 7.2 4.2 5.6 0.6 7.2 4.2 5.8 0.8 7.6 3.8 204 8 192 165 6.4 0.1 7 5.7 10/19/2006 23:10:00 3.9 0.4 4.9 3 3.9 0.4 5.3 3 4.3 0.4 5.3 3.4 203 4 211 165 6.2 0.2 6.7 5.7 10/19/2006 23:20:00 4.4 0.9 6.1 3 4.3 0.9 6.1 3 4.8 0.8 6.8 3.8 189 7 190 165 6.2 0 6.5 5.7 10/19/2006 23:30:00 6.4 0.8 8.4 4.6 6.1 0.8 8 4.6 6.6 0.8 8.8 4.9 179 7 184 165 6 0.1 6.2 5.7 10/19/2006 23:40:00 6.1 0.5 7.6 4.6 6 0.5 7.6 4.6 6.2 0.6 7.6 4.6 193 9 197 165 5.9 0 6.2 5.7 10/19/2006 23:50:00 4.6 1.3 7.2 1.5 4.6 1.3 7.6 1.9 4.7 1.2 8 2.3 206 12 211 165 5.9 0.1 6.2 5.5 10/20/2006 00:00:00 2 1.3 5.3 0.4 2 1.2 5.3 0.4 2.4 1 5.3 0.7 230 27 202 165 5.8 0.1 6 5.2 10/20/2006 00:10:00 4.3 0.7 5.7 2.3 4.3 0.7 5.7 2.3 4.4 0.7 6.1 2.6 204 8 200 165 5.7 0 6 5.5 10/20/2006 00:20:00 5.5 0.8 7.6 3.8 5.6 0.8 7.6 4.2 5.4 0.9 8 3.4 200 6 191 165 5.6 0.1 6 5 10/20/2006 00:30:00 4.4 1 6.5 1.9 4.4 1 6.8 1.9 4.2 1 6.5 1.1 211 8 209 165 5.4 0 5.7 5 10/20/2006 00:40:00 2.4 1.5 5.7 0.4 2.5 1.5 6.1 0.4 2.6 1.1 5.3 0.4 232 23 220 165 5.4 0.1 5.7 5 10/20/2006 00:50:00 6.9 1.3 9.5 3 7 1.3 9.5 3 7.1 1.5 9.9 2.6 204 6 204 165 6 0.1 6.5 5.7 10/20/2006 01:00:00 5.6 1.3 9.1 3.4 5.7 1.3 8.8 3.4 5.5 1.3 8.8 3 210 8 204 165 6.1 0 6.5 5.7 10/20/2006 01:10:00 4.2 0.8 5.7 1.5 4.3 0.8 6.1 1.9 3.9 0.7 5.7 1.5 214 13 215 165 5.9 0 6.2 5.7 10/20/2006 01:20:00 4.6 0.7 6.1 3 4.6 0.7 6.1 3 4.8 0.7 6.5 3 206 8 203 165 6.1 0 6.2 5.7 10/20/2006 01:30:00 4.5 0.8 6.5 2.3 4.4 0.8 6.5 2.3 4.4 0.8 6.5 2.6 207 8 207 165 6.2 0 6.2 5.7 10/20/2006 01:40:00 5.2 0.4 6.5 4.2 5.2 0.4 6.5 4.6 5.4 0.4 6.5 4.2 202 3 206 165 6 0 6.2 5.5 10/20/2006 01:50:00 5.8 0.6 6.8 4.2 5.9 0.6 6.8 4.2 6.1 0.7 7.2 4.6 203 4 204 165 5.9 0 6.2 5.7 10/20/2006 02:00:00 5.3 0.6 6.5 3.8 5.3 0.6 6.8 3.8 5.4 0.7 6.8 3.8 199 3 194 165 5.8 0.1 6.2 5.7 10/20/2006 02:10:00 5.3 0.5 6.5 3.4 5.3 0.5 6.5 3.4 5.1 0.7 6.5 3 199 3 196 165 5.8 0 6 5.7 10/20/2006 02:20:00 5.1 0.6 6.1 3 5.1 0.6 6.1 3 5.2 0.6 6.5 3.4 200 6 199 165 5.9 0 6.2 5.7 10/20/2006 02:30:00 4.2 0.7 5.7 2.3 4.2 0.7 5.7 2.3 4.2 0.8 5.7 2.3 207 5 206 165 5.8 0 6.2 5.7 10/20/2006 02:40:00 1.8 1.1 4.2 0.4 1.7 1.1 4.2 0.4 2.2 1 4.2 0.4 195 8 198 165 5.6 0 5.7 5.5 10/20/2006 02:50:00 1.3 1 3 0.4 1.3 1 3 0.4 1.4 0.9 3.4 0.4 209 19 215 165 5.5 0 6 5.2 10/20/2006 03:00:00 1.9 0.5 3 0.7 1.7 0.6 3 0.4 2.3 0.5 3.4 1.1 189 17 200 165 5.9 0 6.2 5.7 10/20/2006 03:10:00 1 0.4 1.9 0.4 0.7 0.4 1.9 0.4 1.6 0.3 2.3 0.7 175 6 182 165 5.6 0 6 5.5 10/20/2006 03:20:00 1.6 0.6 3 0.4 1.3 0.6 2.6 0.4 2 0.4 3 1.1 183 10 172 165 5.8 0.1 6.2 5.5 10/20/2006 03:30:00 1.1 0.5 2.3 0.4 0.9 0.5 2.3 0.4 1.8 0.4 2.6 1.1 189 11 202 165 5.9 0 6.2 5.7 10/20/2006 03:40:00 0.6 0.4 1.9 0.4 0.5 0.3 1.9 0.4 1.3 0.3 1.9 0.7 174 7 176 165 5.8 0.1 6 5.7 10/20/2006 03:50:00 1.3 0.3 1.9 0.4 1.1 0.3 1.9 0.4 1.8 0.4 2.6 0.7 201 5 200 165 5.8 0 6 5.7 10/20/2006 04:00:00 0.4 0.1 1.1 0.4 0.4 0.1 0.7 0.4 1.1 0.4 1.9 0.4 203 2 205 165 5.7 0 6 5.7 10/20/2006 04:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0.2 1.1 0.4 200 0 165 165 5.7 0 6 5.5 10/20/2006 04:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 200 0 165 165 5.9 0.2 6.2 5.5 10/20/2006 04:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 200 0 165 165 6.1 0.2 6.5 5.5 10/20/2006 04:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 200 0 165 165 5.3 0.1 5.7 5 10/20/2006 04:50:00 0.4 0.1 1.1 0.4 0.4 0 0.7 0.4 0.7 0.3 1.5 0.4 200 0 200 165 5.2 0 5.5 5 10/20/2006 05:00:00 0.9 0.5 1.5 0.4 0.4 0.1 0.7 0.4 1.4 0.3 1.9 0.7 290 79 200 165 5.3 0.1 5.7 5 10/20/2006 05:10:00 1.2 0.3 1.9 0.4 0.4 0.1 1.1 0.4 1.6 0.2 2.3 1.1 1 3 360 165 5.7 0 6 5.5 10/20/2006 05:20:00 1.3 0.3 1.9 0.7 0.6 0.2 1.1 0.4 1.9 0.2 2.3 1.5 11 0 11 165 5.8 0 6 5.7 10/20/2006 05:30:00 1.5 0.2 1.9 1.1 0.5 0.2 1.1 0.4 2.1 0.2 2.3 1.9 10 0 11 165 5.9 0 6 5.7 10/20/2006 05:40:00 1.5 0.3 2.3 1.1 0.7 0.3 1.5 0.4 2.1 0.2 2.6 1.9 7 5 359 165 6 0 6.2 5.7 10/20/2006 05:50:00 1.4 0.4 1.9 0.4 0.8 0.4 1.9 0.4 2 0.3 2.6 1.1 352 6 359 165 5.7 0.1 6 5.7 10/20/2006 06:00:00 1.2 0.3 1.9 0.4 0.6 0.4 1.9 0.4 1.9 0.3 2.6 1.1 6 10 357 165 5.7 0 5.7 5.7 10/20/2006 06:10:00 1.8 0.3 2.3 0.7 1.7 0.3 2.3 0.7 2.4 0.3 3 1.9 28 1 29 165 5.8 0 6 5.7 10/20/2006 06:20:00 0.8 0.2 1.5 0.4 0.7 0.2 1.1 0.4 1.7 0.2 2.3 1.1 27 0 27 165 6.1 0.1 6.2 5.7 10/20/2006 06:30:00 1.4 0.4 1.9 0.7 1.1 0.4 1.9 0.4 2.1 0.2 2.6 1.5 27 0 27 165 6.1 0 6.2 5.7 10/20/2006 06:40:00 1.5 0.4 2.3 0.7 1.1 0.4 1.9 0.4 2.2 0.3 2.6 1.5 27 0 27 165 5.9 0 6 5.7 10/20/2006 06:50:00 1.6 0.3 2.3 0.7 0.6 0.2 1.1 0.4 2.2 0.2 2.6 1.9 16 5 11 165 5.8 0 6 5.7 10/20/2006 07:00:00 1.3 0.3 1.9 0.7 1 0.3 1.5 0.4 2 0.3 2.6 1.5 21 8 11 165 5.6 0.1 6 5.5 10/20/2006 07:10:00 1.4 0.2 1.9 0.7 1 0.3 1.5 0.4 2 0.2 2.3 1.5 28 5 30 165 5.9 0 6.2 5.7 10/20/2006 07:20:00 1.1 0.3 1.9 0.4 0.9 0.3 1.5 0.4 1.9 0.2 2.3 1.5 24 1 23 165 5.7 0 6 5.5 10/20/2006 07:30:00 0.8 0.2 1.1 0.4 0.5 0.2 1.1 0.4 1.7 0.2 1.9 1.1 25 0 25 165 5.8 0 6 5.7 10/20/2006 07:40:00 0.8 0.2 1.5 0.4 0.4 0.1 0.7 0.4 1.6 0.2 1.9 1.1 25 0 25 165 5.8 0 6 5.7 10/20/2006 07:50:00 1.3 0.2 1.9 0.7 0.5 0.2 1.1 0.4 1.9 0.2 2.3 1.5 20 7 7 165 5.8 0 6 5.7 10/20/2006 08:00:00 2.1 0.4 3 1.5 0.8 0.5 2.3 0.4 2.4 0.2 3 1.9 358 4 356 165 5.6 0 5.7 5.5 10/20/2006 08:10:00 2.4 0.2 3 1.9 1.6 0.5 2.6 0.4 2.7 0.2 3.4 2.3 352 3 353 165 5.5 0 5.7 5.5 10/20/2006 08:20:00 2.3 0.3 3 1.5 1.2 0.8 3.4 0.4 2.7 0.2 3.4 2.3 352 5 339 165 5.7 0 5.7 5.5 10/20/2006 08:30:00 2.4 0.5 3.4 1.1 2.2 0.6 3.4 0.7 2.7 0.5 3.8 1.5 339 8 341 165 5.7 0.1 6 5.5 10/20/2006 08:40:00 1.9 0.5 3 0.7 0.8 0.4 2.6 0.4 2.3 0.4 3 1.1 1 6 353 165 6.1 0.1 6.5 5.7 10/20/2006 08:50:00 0.8 0.6 2.3 0.4 0.4 0.2 1.1 0.4 1.2 0.6 3 0.4 12 19 3 165 6.9 0.4 7.5 6.2 10/20/2006 09:00:00 1.2 0.6 3 0.4 0.7 0.5 2.6 0.4 1.5 0.6 3 0.4 4 10 358 165 8 0.3 8.8 7 10/20/2006 09:10:00 0.4 0 0.7 0.4 0.4 0 0.7 0.4 0.4 0.1 0.7 0.4 355 3 355 165 9.4 0.4 9.8 8.3 10/20/2006 09:20:00 0.4 0 0.7 0.4 0.4 0 0.7 0.4 0.4 0.2 1.5 0.4 51 58 118 165 10.3 0.1 10.9 9.8 10/20/2006 09:30:00 0.4 0.1 1.1 0.4 0.4 0.1 0.7 0.4 0.6 0.4 1.9 0.4 110 21 102 165 9.7 0.2 10.3 9.3 10/20/2006 09:40:00 0.5 0.3 1.9 0.4 0.4 0.1 1.1 0.4 0.6 0.4 1.9 0.4 72 23 12 165 9.9 0.1 10.3 9.6 10/20/2006 09:50:00 1.2 0.6 2.3 0.4 0.8 0.5 1.9 0.4 1.2 0.4 1.9 0.4 32 15 32 165 9.2 0.2 9.6 8.8 10/20/2006 10:00:00 2.3 0.4 3 1.1 2 0.5 3 0.4 2.1 0.6 3 0.4 40 4 40 165 8.7 0.5 9.3 7.5 10/20/2006 10:10:00 2.2 0.6 3.8 0.4 2 0.6 3.4 0.4 2.2 0.5 3.4 0.4 74 22 68 165 7.9 0.4 8.8 7.3 10/20/2006 10:20:00 1.7 0.8 3 0.4 1.4 0.8 2.6 0.4 1.6 0.7 2.6 0.4 57 66 88 165 9 0.1 9.3 8.5 10/20/2006 10:30:00 1.9 0.6 4.2 0.7 1.5 0.7 4.2 0.4 2 0.5 3.8 0.4 45 29 93 165 8.9 0 9 8.8 10/20/2006 10:40:00 1.4 0.9 3.4 0.4 1.1 0.9 3.8 0.4 1.3 0.9 3.8 0.4 49 53 70 165 9.4 0.3 9.8 8.8 10/20/2006 10:50:00 3.1 0.7 4.9 1.5 2.9 0.8 4.9 1.1 3.1 0.7 4.9 1.1 59 16 39 165 8.6 0.2 9 8 10/20/2006 11:00:00 2.8 0.7 4.2 1.5 2.5 0.9 4.2 0.7 2.7 0.7 4.2 1.1 53 13 39 165 8.7 0.2 9.3 8.3 10/20/2006 11:10:00 3.6 0.3 4.2 3 3.4 0.3 4.2 2.6 3.6 0.3 4.6 2.6 38 7 48 165 8.3 0 8.8 8.3 10/20/2006 11:20:00 3.3 0.5 4.2 2.3 2.9 0.7 4.2 1.5 3.3 0.4 4.2 2.3 25 8 34 165 8.3 0.1 8.8 8 10/20/2006 11:30:00 3.3 0.3 3.8 2.3 3 0.4 3.8 1.9 3.2 0.4 4.2 1.9 41 7 27 165 8.5 0 8.8 8.3 10/20/2006 11:40:00 2.5 0.4 3.4 1.9 2.1 0.4 3 1.1 2.6 0.3 3.4 1.9 49 9 50 165 8.3 0 8.8 8 10/20/2006 11:50:00 2.5 0.3 3.4 1.5 2.1 0.4 3 1.1 2.5 0.4 3.8 1.5 43 11 34 165 8.8 0.2 9.6 8.5 10/20/2006 12:00:00 3.2 0.4 4.2 2.3 3 0.4 3.8 1.9 3.2 0.4 4.2 2.3 38 8 39 165 8.9 0.3 9.6 8.5 10/20/2006 12:10:00 3.3 0.5 4.6 2.3 3 0.5 4.6 1.9 3.1 0.5 4.2 1.9 39 12 44 165 8.7 0.1 9.3 8.3 10/20/2006 12:20:00 2.9 0.6 4.6 1.1 2.3 0.8 4.2 0.4 2.7 0.7 4.2 0.4 22 14 32 165 8.7 0 9 8.5 10/20/2006 12:30:00 3.8 0.8 5.7 2.3 3.5 1 5.7 1.5 3.8 0.8 5.7 2.3 34 10 37 165 8.5 0.4 9.6 8 10/20/2006 12:40:00 4.9 0.6 6.5 3 4.7 0.6 6.1 3 4.6 0.6 6.5 3 45 9 25 165 7.9 0 8 7.8 10/20/2006 12:50:00 4.7 0.6 5.7 3 4.4 0.6 5.7 2.6 4.7 0.5 6.1 3.4 31 8 41 165 8 0.2 8.5 7.5 10/20/2006 13:00:00 4.4 0.5 5.3 3 4.2 0.6 5.3 2.6 4.3 0.6 5.7 2.6 37 8 37 165 8.2 0.1 8.5 8 10/20/2006 13:10:00 4.1 0.7 5.3 2.3 3.9 0.8 5.3 1.5 4.2 0.8 5.7 2.3 32 9 28 165 8.5 0.4 9 7.8 10/20/2006 13:20:00 4.8 0.4 5.7 3.4 4.6 0.5 5.7 3.4 4.7 0.5 6.1 3.4 34 5 33 165 7.5 0.2 8 7.3 10/20/2006 13:30:00 4.8 0.5 5.7 3.4 4.6 0.5 5.7 3 4.7 0.6 5.7 3 33 6 28 165 7.3 0.1 7.5 7 10/20/2006 13:40:00 4.4 0.3 5.3 3.4 4.2 0.4 4.9 3.4 4.6 0.4 5.3 3.4 36 5 39 165 7.8 0 8.3 7.5 10/20/2006 13:50:00 4.7 0.4 5.7 3.4 4.5 0.5 5.3 3 4.7 0.5 5.7 3.4 27 5 25 165 7.4 0.2 8.3 7.3 10/20/2006 14:00:00 4.7 0.6 6.1 2.6 4.4 0.7 5.7 2.3 4.6 0.6 6.1 3 32 8 36 165 8.1 0.1 8.8 7.8 10/20/2006 14:10:00 4.6 0.6 6.5 3.4 4.4 0.7 6.5 3 4.7 0.6 6.1 3 34 7 27 165 8.3 0 8.8 8 10/20/2006 14:20:00 4.3 0.6 5.7 2.6 3.9 0.7 5.3 1.9 4.3 0.6 5.7 3 27 8 31 165 8.3 0 8.5 8.3 10/20/2006 14:30:00 4.6 0.6 5.7 3 4.2 0.7 5.3 2.6 4.5 0.6 6.1 3 27 8 20 165 8.5 0 8.8 8.3 10/20/2006 14:40:00 4.7 0.5 5.7 3.4 4.4 0.5 5.7 3 4.7 0.5 6.1 3.4 33 8 43 165 8.3 0 8.5 8.3 10/20/2006 14:50:00 4.6 0.5 5.7 3.4 4.3 0.5 5.3 3 4.6 0.6 6.1 2.6 28 8 34 165 8.4 0.1 8.5 8.3 10/20/2006 15:00:00 4.4 0.5 5.7 2.6 4 0.6 5.3 2.3 4.4 0.5 5.7 2.6 22 7 23 165 8.7 0.1 9.3 8.5 10/20/2006 15:10:00 4.6 0.5 6.1 2.6 4 0.7 5.7 2.3 4.5 0.6 6.1 3 21 9 25 165 8.8 0 9.3 8.5 10/20/2006 15:20:00 4.3 0.5 5.7 3 3.6 0.7 5.3 2.3 4.2 0.6 6.1 2.6 15 9 31 165 9 0 9.6 8.8 10/20/2006 15:30:00 5.1 0.7 6.5 3.4 4.1 1 6.5 1.5 5.1 0.7 6.5 3 7 11 7 165 8.9 0 9.6 8.8 10/20/2006 15:40:00 4.8 0.6 6.1 3.4 3.2 0.9 6.1 1.5 4.9 0.6 6.1 3.4 358 6 0 165 8.9 0 9.6 8.5 10/20/2006 15:50:00 5.4 0.6 6.8 3.8 3.8 1 6.8 1.9 5.6 0.8 7.2 3.8 359 7 7 165 8.9 0 9.3 8.5 10/20/2006 16:00:00 4.4 0.5 6.1 3 3.1 0.9 5.3 1.1 4.3 0.6 6.1 3 10 8 26 165 8.4 0 9 8.3 10/20/2006 16:10:00 3.8 0.6 5.3 2.3 2.9 0.7 4.9 1.1 3.6 0.5 4.9 2.3 2 13 4 165 8.9 0.1 9 8.3 10/20/2006 16:20:00 4.5 0.8 6.1 2.6 3.3 1 5.3 0.7 4.4 0.9 6.5 2.6 11 9 1 165 8.7 0 9 8.5 10/20/2006 16:30:00 5.2 0.8 7.2 3.4 3.7 1 6.8 1.9 5.4 1 7.6 3 359 9 11 165 8.1 0.1 8.5 7.8 10/20/2006 16:40:00 5.7 0.8 8.8 4.2 4.2 1.3 8.4 1.9 5.7 0.8 8.4 3.8 8 7 18 165 7.3 0.1 7.8 7 10/20/2006 16:50:00 6.4 1 8.4 3.4 4.8 1 7.6 1.9 6.6 1 8.8 3.8 9 8 3 165 6.8 0 7 6.7 10/20/2006 17:00:00 6.4 0.8 8.8 4.6 5 1.2 8.4 2.3 6.4 0.9 9.5 3.8 1 10 354 165 6.6 0 7 6.5 10/20/2006 17:10:00 6.2 0.8 8 4.2 4.3 1 6.8 2.3 6.1 0.9 8.4 4.2 2 7 360 165 6.5 0.1 6.7 6.2 10/20/2006 17:20:00 6.6 0.9 8.4 4.6 4.5 1.1 7.6 2.6 6.5 0.8 8.8 4.2 3 7 7 165 6.2 0 6.2 5.7 10/20/2006 17:30:00 6.6 0.7 8.4 4.2 5.4 1.4 8 3 6.2 0.7 8 4.2 352 8 2 165 6 0.1 6.2 5.7 10/20/2006 17:40:00 6.6 0.8 9.1 4.2 6.4 1 9.5 3.4 6.3 0.9 8.8 4.6 345 8 352 165 5.8 0 6 5.7 10/20/2006 17:50:00 6.8 1 9.5 4.9 6.1 1.1 8.8 3 6.6 1.1 10.3 4.2 351 9 1 165 5.7 0.1 6 5.5 10/20/2006 18:00:00 6.9 1 9.9 4.6 5.8 1.4 8.8 2.3 6.7 0.9 8.8 4.2 356 11 358 165 5.8 0.1 6.2 5.5 10/20/2006 18:10:00 7.1 1 9.5 4.6 6.8 1.2 10.3 3.4 6.4 1 8.4 3.8 346 8 349 165 5.9 0 6.2 5.7 10/20/2006 18:20:00 7.3 1.3 11.1 3 6.5 1.6 10.3 2.6 6.9 1.2 11.1 4.2 349 11 5 165 5.9 0 6.2 5.5 10/20/2006 18:30:00 7.4 1.3 10.3 4.6 6.2 1.8 10.3 2.6 7.4 1.4 10.3 4.6 352 11 4 165 5.9 0.1 6.2 5.5 10/20/2006 18:40:00 8.4 2 13.7 4.6 6.7 2 13 3 8.2 2.1 13.3 4.6 3 11 16 165 6 0.1 6.2 5.5 10/20/2006 18:50:00 8.6 1.5 12.6 5.7 6.5 1.5 10.7 3.4 8.4 1.5 12.2 4.9 4 9 358 165 6.1 0.2 6.2 5.5 10/20/2006 19:00:00 8.6 1.2 12.2 5.3 7 1.2 11.1 3.8 8.5 1.2 11.8 5.3 354 7 5 165 5.6 0.1 5.7 5 10/20/2006 19:10:00 8.3 0.8 10.3 6.1 6.8 1.5 10.3 3.8 8.2 0.8 9.9 6.1 355 8 350 165 5.4 0 5.7 5 10/20/2006 19:20:00 7.6 0.9 10.3 5.7 7.3 1.2 10.3 3.8 7.4 0.8 9.5 5.3 346 8 343 165 5.5 0 5.7 5 10/20/2006 19:30:00 8.1 0.9 10.7 5.7 7.6 1.3 10.3 3.4 7.8 1 10.3 5.3 349 6 351 165 5.4 0 5.7 5 10/20/2006 19:40:00 8.1 1.3 10.7 5.3 8.1 1.4 11.1 4.2 7.6 1.3 10.7 4.6 344 7 348 165 5.4 0 5.7 5 10/20/2006 19:50:00 8.8 1.1 11.8 6.1 7.7 1.8 12.2 3.4 8.8 1.1 11.5 5.3 351 9 358 165 5.5 0 5.7 5 10/20/2006 20:00:00 7.8 1.1 10.7 4.9 6.4 1.5 10.3 3 7.8 1.2 10.7 4.9 354 10 6 165 5.4 0 5.7 5 10/20/2006 20:10:00 7.4 1.1 12.2 5.7 7.2 1 10.3 3.4 7.5 1.1 12.6 5.7 345 6 4 165 5.2 0.1 5.7 4.8 10/20/2006 20:20:00 8.1 1.2 11.8 5.7 7.3 1.3 11.1 3.8 8 1.2 11.5 5.7 349 8 356 165 5.2 0.1 5.5 5 10/20/2006 20:30:00 9.2 1.3 12.2 6.1 9.1 1.2 12.2 6.1 8.9 1.2 12.2 5.7 335 8 331 165 5.2 0 5.5 5 10/20/2006 20:40:00 10 1.2 13.3 7.2 9.8 1.2 13.3 6.8 9.7 1.3 13 6.1 330 8 336 165 5.4 0 5.7 5 10/20/2006 20:50:00 9.6 1.2 13 6.5 9.5 1.2 13 6.5 9.2 1.4 12.6 5.3 333 9 316 165 5.4 0 5.7 5.2 10/20/2006 21:00:00 8.1 1.2 12.2 5.7 7.9 1.4 11.8 3.4 8 1 11.1 6.1 341 10 336 165 5.2 0.1 5.7 4.8 10/20/2006 21:10:00 9.3 1.2 13.3 6.8 9.2 1.2 12.6 5.7 9.2 1.1 12.2 5.7 337 9 331 165 5.1 0.2 5.5 4.5 10/20/2006 21:20:00 11 1.2 14.5 8 10.9 1.2 14.1 7.6 10.7 1.2 14.1 6.8 336 8 337 165 5.3 0.1 5.5 5 10/20/2006 21:30:00 11.7 1 14.9 8.4 11.6 1 14.5 6.8 11.4 1.1 14.5 7.6 335 8 336 165 5.3 0 5.7 5 10/20/2006 21:40:00 10.5 1.3 13 6.8 10.3 1.3 13 6.5 10.2 1.3 13.3 6.5 332 9 328 165 5.3 0.2 5.7 4.8 10/20/2006 21:50:00 9.4 1.5 13 5.7 8.6 2 13.7 3.4 9.1 1.5 13.7 5.7 343 12 330 165 5.4 0.1 5.7 4.8 10/20/2006 22:00:00 10.3 1.3 13.3 6.5 10.3 1.3 13.3 6.5 9.9 1.3 13 6.8 336 8 338 165 5.2 0.2 6 4.8 10/20/2006 22:10:00 8.2 1.2 13.3 5.7 7.9 1.5 14.5 4.2 7.8 1.3 13.3 4.6 342 13 346 165 5.2 0.1 5.5 4.8 10/20/2006 22:20:00 8.3 1 11.1 4.9 6.9 1.3 10.3 3.4 8.3 0.9 11.1 5.7 352 9 356 165 5.1 0 5.2 4.8 10/20/2006 22:30:00 7.9 1.1 11.1 4.6 7.4 1.1 10.3 4.2 7.8 1 11.8 5.3 344 12 4 165 5.1 0 5.2 4.8 10/20/2006 22:40:00 9.7 1.5 14.9 5.3 9.4 1.6 14.5 4.9 9.3 1.5 13.3 5.3 341 11 347 165 5.2 0 5.5 5 10/20/2006 22:50:00 10.9 1.7 15.6 6.8 10.4 1.9 15.3 5.7 10.3 1.9 15.3 6.1 334 12 337 165 5.4 0 5.7 4.8 10/20/2006 23:00:00 11.1 2.1 15.3 6.1 10.2 2.6 15.3 3.8 11 2.1 15.6 6.5 343 13 341 165 5.6 0 5.7 5 10/20/2006 23:10:00 11.6 1.9 16.1 6.5 11.3 1.9 16.1 6.5 11.4 1.8 16.4 6.1 335 11 330 165 5.5 0 5.7 5 10/20/2006 23:20:00 13 1.9 17.9 7.6 12.7 2.3 17.6 5.7 12.8 2 18.3 7.6 336 10 330 165 5.4 0 5.7 5.2 10/20/2006 23:30:00 12.4 1.5 16.1 8 12.3 1.5 16.4 7.6 12 1.7 15.6 5.7 335 8 329 165 5.6 0 5.7 5.2 10/20/2006 23:40:00 12.6 1.5 16.8 8.4 12.4 1.6 16.4 7.2 12.2 1.5 17.2 8.8 337 10 328 165 5.6 0 5.7 5.2 10/20/2006 23:50:00 13.1 1.3 16.8 9.9 13 1.3 16.4 9.1 12.8 1.5 16.8 8.8 335 8 332 165 5.6 0 5.7 5.2 10/21/2006 00:00:00 12.5 1.7 17.9 8.8 12.3 1.7 18.3 7.6 12.3 1.7 17.2 8.4 334 10 355 165 5.6 0 6 5.2 10/21/2006 00:10:00 13 1.7 16.8 7.6 12.8 1.8 17.2 7.2 12.8 1.7 17.2 7.6 335 9 344 165 5.6 0 5.7 5.2 10/21/2006 00:20:00 14.1 1.6 19.9 8.8 14 1.7 20.2 8.8 13.9 1.5 18.7 9.1 336 9 345 165 5.6 0 5.7 5 10/21/2006 00:30:00 13.1 1.7 17.9 8.8 13 1.8 17.6 8.4 12.7 1.8 17.6 8 337 9 334 165 5.6 0 5.7 5 10/21/2006 00:40:00 12.9 1.7 16.4 7.2 12.6 2 16.1 7.2 12.2 1.8 15.6 7.6 336 10 334 165 5.6 0.1 5.7 5.2 10/21/2006 00:50:00 13.6 1.5 17.6 8.8 13.2 1.8 17.2 6.5 13.1 1.7 16.8 8.4 339 10 352 165 5.6 0.2 6 5 10/21/2006 01:00:00 13.2 1.8 19.1 9.1 12.9 1.9 19.5 8.8 12.9 1.7 19.1 8.8 339 10 345 165 5.7 0.2 6 5.2 10/21/2006 01:10:00 13.3 1.7 19.5 9.5 13.2 1.7 19.1 9.1 13.1 1.7 18.3 8.4 335 9 336 165 5.8 0.1 6 5.2 10/21/2006 01:20:00 14.2 1.7 18.7 9.9 14.1 1.8 17.9 9.9 13.8 1.7 17.9 9.9 334 9 340 165 5.8 0.1 6 5.5 10/21/2006 01:30:00 13.8 2 19.5 7.2 13.4 2.1 18.7 6.5 13.4 2 19.1 6.5 339 11 326 165 5.9 0 6.2 5.5 10/21/2006 01:40:00 13.7 1.7 17.2 8 13.4 1.7 18.7 8.4 13 1.7 17.2 8 340 9 351 165 6.1 0.1 6.2 5.5 10/21/2006 01:50:00 13.7 1.5 19.5 9.1 13.2 1.7 20.2 8.4 13.1 1.9 19.1 8.4 335 11 339 165 6 0.1 6.2 5.5 10/21/2006 02:00:00 13.1 1.8 19.5 9.1 12.3 2 18.3 6.5 12.4 1.8 18.3 8.4 339 13 2 165 6 0.1 6.2 5.5 10/21/2006 02:10:00 14.4 1.7 18.7 10.3 14.2 1.7 19.1 9.9 13.9 1.8 18.3 10.3 338 8 347 165 6.1 0.1 6.2 5.5 10/21/2006 02:20:00 12.7 1.6 16.4 8 12.3 1.5 16.1 8.4 11.7 1.8 16.8 8 324 14 356 165 5.9 0.2 6.2 5.2 10/21/2006 02:30:00 13.3 1.3 16.8 9.5 13.1 1.3 16.8 8.4 11.5 1.5 15.3 6.5 310 9 317 165 5.4 0 5.7 5 10/21/2006 02:40:00 16.8 1.5 21 12.2 16.6 1.5 20.6 12.2 13.7 1.9 18.3 8.8 307 5 310 165 5.4 0.1 5.7 5 10/21/2006 02:50:00 17.7 1.1 20.6 14.5 17.5 1.1 19.9 14.5 14 1.4 17.6 10.3 306 4 304 165 5.1 0 5.5 4.8 10/21/2006 03:00:00 17.3 1.2 21 14.1 17.1 1.2 21 13.7 15.8 1.9 20.6 11.5 313 5 316 165 5.1 0 5.5 5 10/21/2006 03:10:00 17 1.2 19.9 13 17 1.3 19.9 13 16.8 1.3 20.6 12.6 317 4 319 165 4.9 0 5 4.8 10/21/2006 03:20:00 15.4 1.1 17.9 12.6 15.4 1.2 17.9 12.2 13.6 1.5 17.6 9.9 310 6 304 165 4.7 0.1 5 4.5 10/21/2006 03:30:00 15.4 1 17.9 12.2 15.3 1 17.6 11.8 12.5 1.4 18.3 8.8 307 5 302 165 4.6 0 4.8 4.5 10/21/2006 03:40:00 14.5 1.3 18.3 11.5 14.4 1.3 17.6 11.5 12.3 1.5 16.8 8.8 308 6 302 165 4.6 0 5 4.5 10/21/2006 03:50:00 13.5 1.2 17.2 10.7 13.4 1.2 16.8 10.7 12.1 1.3 14.9 8.4 309 6 307 165 4.8 0.1 5 4.5 10/21/2006 04:00:00 13 1.2 15.6 9.9 12.9 1.2 15.3 9.5 11.4 1.1 14.5 7.6 309 5 297 165 4.5 0 4.8 4.3 10/21/2006 04:10:00 12.5 1.3 16.1 8.8 12.4 1.3 16.1 8.8 11.4 1.5 15.6 6.8 311 6 295 165 4.3 0 4.5 4.3 10/21/2006 04:20:00 14.4 1.7 18.3 9.1 14.3 1.7 18.3 9.1 12.2 1.7 16.1 8 309 6 305 165 4.3 0 4.5 4.3 10/21/2006 04:30:00 16.5 1.2 19.9 13.3 16.4 1.3 20.2 12.6 14.4 1.7 19.9 10.3 310 5 315 165 4.3 0 4.5 4.3 10/21/2006 04:40:00 15.3 1.3 19.9 10.7 15.1 1.3 19.5 10.7 13.5 1.7 17.9 9.5 312 6 305 165 4.4 0 4.8 4.3 10/21/2006 04:50:00 15.5 1.2 19.1 12.2 15.2 1.3 19.1 11.8 14.1 1.3 19.1 11.1 314 6 318 165 4.4 0 4.8 4.3 10/21/2006 05:00:00 14.8 1 16.8 11.8 14.5 1 16.4 11.8 13.7 1.3 16.4 9.9 314 4 315 165 4.4 0 4.5 4.3 10/21/2006 05:10:00 14.9 0.9 17.9 12.6 14.7 0.9 17.6 12.2 13.9 1.2 16.4 9.9 314 4 313 165 4.5 0 4.8 4.3 10/21/2006 05:20:00 14.8 1 17.2 11.1 14.6 1.1 16.8 11.1 13.7 1.2 16.4 10.3 313 4 310 165 4.6 0.1 4.8 4.3 10/21/2006 05:30:00 14.7 1 17.2 11.1 14.4 1 16.4 10.3 13.8 1.2 16.4 10.3 316 5 313 165 4.6 0.1 4.8 4 10/21/2006 05:40:00 14.2 0.9 16.4 11.1 13.9 0.9 16.4 11.5 13.7 1.2 17.2 10.3 317 6 322 165 4.6 0.1 5 4.3 10/21/2006 05:50:00 13.2 1 15.6 10.3 12.9 1 16.1 10.3 12.4 1.2 15.6 9.1 316 7 304 165 4.6 0.1 4.8 3.8 10/21/2006 06:00:00 13 1.1 15.6 10.7 12.8 1.1 15.6 10.3 11.9 1.1 14.5 7.6 314 8 310 165 4.4 0 4.8 3.8 10/21/2006 06:10:00 13.5 1.3 17.6 10.3 13.2 1.3 16.8 9.9 13 1.5 16.8 9.1 320 6 324 165 4.3 0 4.5 3.8 10/21/2006 06:20:00 14.2 1.5 17.9 10.3 13.9 1.5 18.3 10.3 13.6 1.4 18.3 9.9 320 8 308 165 4.4 0 4.8 3.8 10/21/2006 06:30:00 15.6 1 17.9 11.5 15.4 1.1 17.6 11.5 14.3 1.3 17.6 9.5 313 6 313 165 4.5 0 4.8 3.8 10/21/2006 06:40:00 15.7 1.1 18.3 13 15.4 1.1 17.9 13 15 1.1 17.9 12.2 316 5 316 165 4.4 0 4.8 3.8 10/21/2006 06:50:00 16.3 1.2 19.1 13 16.1 1.2 18.7 13 15.4 1.3 19.1 11.5 315 6 317 165 4.4 0 4.8 4.3 10/21/2006 07:00:00 15.8 0.9 17.2 12.2 15.5 0.9 17.2 11.8 14.9 1 16.8 11.1 316 4 312 165 4.2 0 4.5 4 10/21/2006 07:10:00 15.7 0.7 17.6 13.7 15.6 0.7 17.2 13.3 14.6 1 17.6 11.5 313 3 312 165 4.3 0 4.5 4 10/21/2006 07:20:00 14.2 0.7 16.8 12.6 14.1 0.7 16.8 12.2 13.2 0.9 15.6 10.3 311 3 309 165 4.2 0.1 4.5 4.3 10/21/2006 07:30:00 13.1 0.7 14.9 11.1 13 0.7 14.9 11.1 11.8 1 14.1 9.1 310 3 311 165 4.1 0 4.5 4 10/21/2006 07:40:00 12.4 0.5 13.7 11.1 12.3 0.5 14.1 10.7 10.4 1 12.6 8.4 308 3 304 165 4.1 0 4.5 4 10/21/2006 07:50:00 11.4 0.7 13.3 9.9 11.4 0.6 13.3 9.9 10.3 0.9 12.6 8 310 3 310 165 4.1 0 4.5 4 10/21/2006 08:00:00 9.4 0.6 10.7 7.6 9.3 0.7 10.7 7.6 8.4 1 10.7 5.7 310 4 311 165 4.1 0 4.5 3.8 10/21/2006 08:10:00 8.6 0.5 10.3 6.8 8.5 0.6 10.3 6.5 7.6 0.8 9.5 5.3 309 4 312 165 4.1 0 4.3 4 10/21/2006 08:20:00 8.2 0.7 9.9 6.1 8.1 0.7 9.9 6.1 6.9 0.6 8.8 5.3 308 3 304 165 4.1 0 4.5 3.8 10/21/2006 08:30:00 6.3 0.7 8.4 4.2 6.2 0.6 8.4 4.2 5.7 0.6 7.2 4.6 310 4 304 165 4.3 0 4.8 4.3 10/21/2006 08:40:00 5.2 0.7 6.8 3.4 5.2 0.7 7.2 3.4 4.2 0.6 5.7 2.6 303 8 301 165 4.6 0 4.8 4.5 10/21/2006 08:50:00 5.8 0.7 7.6 4.2 5.8 0.7 8 4.2 4.6 0.8 7.6 3 296 7 287 165 5.1 0.2 5.5 4.5 10/21/2006 09:00:00 6.4 0.6 8.4 4.9 6.4 0.6 8 4.9 5.3 0.7 7.2 3.8 292 5 295 165 5.3 0 5.7 5 10/21/2006 09:10:00 7.1 0.6 8.4 5.3 7.1 0.6 8.8 5.7 6.7 0.8 8.4 3.8 285 5 290 165 5.4 0 5.7 5 10/21/2006 09:20:00 6.9 0.7 8.4 4.6 7.2 0.6 8.4 5.3 6.9 0.7 8.4 4.6 277 5 277 165 5.5 0 5.7 5 10/21/2006 09:30:00 7.1 0.8 9.1 4.9 7.5 0.7 9.1 6.1 7.2 0.8 9.1 4.2 278 6 284 165 5.7 0 5.7 5.2 10/21/2006 09:40:00 6.4 0.8 8.4 3.8 6.6 0.8 8.4 4.6 6.3 0.9 8 4.2 281 7 287 165 5.7 0.2 6 5 10/21/2006 09:50:00 6.9 0.9 9.1 4.9 7 0.8 9.1 4.9 6.6 0.9 8.8 3.8 283 6 283 165 5.7 0.1 6.2 5.5 10/21/2006 10:00:00 7.5 0.8 9.5 5.7 7.6 0.7 9.9 6.1 6.6 1 9.1 4.6 291 6 290 165 5.8 0 6 5.7 10/21/2006 10:10:00 8.2 0.9 9.9 5.7 8.1 0.8 9.9 5.7 6.6 0.8 9.1 4.6 303 7 296 165 5.8 0 6 5.7 10/21/2006 10:20:00 8.8 1.3 12.2 5.3 8.7 1.3 12.2 5.7 7.5 1.5 12.6 4.6 303 9 312 165 5.9 0 6 5.7 10/21/2006 10:30:00 9 1 11.1 6.1 9 1.1 11.5 6.1 7.4 1.2 10.3 4.6 294 6 288 165 5.9 0 6.2 5.7 10/21/2006 10:40:00 8.2 1.1 10.7 5.7 8.2 1.1 11.1 5.3 6.6 1.1 9.5 4.6 298 8 297 165 6 0 6.2 5.7 10/21/2006 10:50:00 8.2 1.1 11.1 5.3 8.2 1.1 11.1 5.3 6.8 1.2 10.3 3.8 301 9 293 165 6.3 0.1 7 6 10/21/2006 11:00:00 9.5 2.3 14.5 4.9 9.4 2.3 13.7 4.6 7.6 2 13 3.8 298 8 293 165 6.3 0 6.7 6.2 10/21/2006 11:10:00 11.1 1.1 14.1 8.4 11.1 1.1 14.1 8.4 9 1.2 12.6 6.5 297 7 300 165 6.3 0 6.5 6.2 10/21/2006 11:20:00 11.2 1.3 14.5 8.4 11.1 1.4 14.5 8.4 8.7 1.3 14.9 6.1 300 6 302 165 6.4 0 6.7 6.2 10/21/2006 11:30:00 9.7 1.2 12.6 6.8 9.6 1.2 12.2 6.5 7.6 1 10.7 4.9 303 6 309 165 6.6 0 7.3 6.2 10/21/2006 11:40:00 9.3 1 13.3 6.5 9.2 1 13 6.5 7.8 1.3 11.8 5.3 294 7 285 165 6.8 0 7 6.7 10/21/2006 11:50:00 8.7 1.1 11.1 5.3 8.6 1.1 11.1 5.7 7 1.2 9.9 4.6 294 7 280 165 6.9 0 7.3 6.7 10/21/2006 12:00:00 9.6 0.9 13.7 7.2 9.7 0.9 14.5 6.8 8.9 1.3 13.7 5.7 287 7 284 165 7.1 0 7.8 7 10/21/2006 12:10:00 7.1 1.3 10.7 4.2 7.6 1.4 10.7 4.9 7.3 1.4 10.3 4.6 278 9 284 165 7.5 0.2 8.3 7.3 10/21/2006 12:20:00 6.1 1.1 9.9 3 7 1.3 10.3 3.8 6.9 1.3 9.9 3.8 273 9 278 165 8.1 0.1 8.5 7.8 10/21/2006 12:30:00 6.6 0.9 8.8 3.8 7.5 1 9.5 5.3 7.2 1 9.5 4.9 272 5 282 165 8.3 0 8.5 8 10/21/2006 12:40:00 7.7 1 10.3 5.3 8.3 1 10.3 5.3 8 1.1 10.3 3.8 278 9 285 165 8.1 0 8.5 7.8 10/21/2006 12:50:00 5 0.9 7.2 2.6 5.7 1.1 8 2.6 5.5 1.1 8 2.3 272 9 274 165 8.8 0.3 9.3 7.8 10/21/2006 13:00:00 5.2 0.9 8.8 3 5.3 1 9.1 2.6 4.9 1 7.2 2.6 284 12 278 165 9.2 0 9.3 9 10/21/2006 13:10:00 5.8 1.2 8.4 3.4 6 1.1 8.8 3.8 5.5 1 8 3 283 10 282 165 9.2 0.1 9.6 8.8 10/21/2006 13:20:00 6 1 8.8 3.4 6.9 1 9.5 4.6 6.7 1 9.1 4.2 270 7 271 165 9.4 0.3 10.1 8.8 10/21/2006 13:30:00 4.5 1.4 7.2 2.3 4.5 1.6 7.6 1.9 4 1.6 7.6 1.5 290 13 281 165 9.7 0.1 10.6 9.3 10/21/2006 13:40:00 5.6 0.8 7.2 3.4 5.6 0.9 7.6 3 4.8 1 7.2 2.3 295 9 281 165 9.6 0.1 10.3 9.3 10/21/2006 13:50:00 5.5 1.2 8.4 2.6 5.6 1 8.4 3.4 5.1 1 8.4 3 284 10 293 165 9.7 0.2 10.3 9.3 10/21/2006 14:00:00 5.9 0.8 8.8 3.8 6 0.8 8.4 3.4 5.7 1 8.8 3.4 284 8 286 165 9.6 0 9.8 9.3 10/21/2006 14:10:00 6.3 1.2 9.1 3.4 6.3 1.2 9.1 3 5.4 1.2 8.4 2.6 296 10 297 165 9.4 0.1 10.1 9 10/21/2006 14:20:00 7.2 1.1 9.9 4.9 7.2 1.1 10.3 4.9 6.2 1.1 8.8 3.8 294 10 284 165 9 0 9.3 8.8 10/21/2006 14:30:00 6.1 1.5 9.9 2.6 6.1 1.6 9.9 2.6 5.4 1.7 9.1 2.3 290 10 292 165 9 0 9.3 8.8 10/21/2006 14:40:00 6.6 1.8 11.1 2.6 6.9 1.7 10.7 3.4 6.5 1.5 10.3 3 280 11 287 165 9.1 0.2 9.6 8.8 10/21/2006 14:50:00 7.6 1.1 10.3 4.2 8.4 1 10.7 5.3 8 1 10.7 4.9 275 7 287 165 8.8 0 9 8.5 10/21/2006 15:00:00 7 1.1 9.9 4.2 8 0.7 9.9 6.1 7.9 0.7 9.9 5.3 273 7 287 165 9 0 9.3 8.8 10/21/2006 15:10:00 6.5 1 9.1 3.8 6.7 1 9.1 4.2 6.2 1.1 8.8 3.4 282 8 289 165 9 0 9.3 8.8 10/21/2006 15:20:00 6 1.1 8.8 3.8 6.1 1.1 8.8 3.4 5 1 8 2.6 297 9 310 165 9 0 9.3 8.8 10/21/2006 15:30:00 5.4 0.9 6.8 2.6 5.4 0.8 6.8 3.4 4.8 0.9 6.8 2.3 288 10 282 165 9 0 9.3 9 10/21/2006 15:40:00 4.5 0.8 6.8 2.6 4.6 1 6.8 2.3 4.4 1 7.2 1.9 282 13 284 165 9 0 9.3 8.8 10/21/2006 15:50:00 4.6 0.7 6.1 3 4.6 0.8 6.5 2.6 4.3 0.8 6.1 1.9 282 10 279 165 9.1 0 9.3 9 10/21/2006 16:00:00 4.1 0.6 5.7 2.6 4.1 0.6 5.7 2.6 3.9 0.6 5.7 2.3 281 8 290 165 9 0 9 9 10/21/2006 16:10:00 4 0.9 5.7 1.5 4.3 0.9 6.5 1.9 4.3 0.9 6.1 2.3 271 9 282 165 9 0 9.6 8.8 10/21/2006 16:20:00 2.8 0.7 4.6 1.1 3 0.7 4.9 1.5 3.1 0.7 4.9 1.5 254 12 277 165 9.5 0.3 10.3 8.8 10/21/2006 16:30:00 3 0.7 4.6 1.5 3.3 0.6 4.6 1.5 3.5 0.6 4.9 1.9 269 7 276 165 9.1 0.2 9.8 8.8 10/21/2006 16:40:00 3.7 0.4 4.9 2.3 3.6 0.5 4.9 2.3 3.6 0.5 4.9 2.3 281 6 273 165 8.6 0 8.8 8.5 10/21/2006 16:50:00 2.7 0.5 3.8 1.5 2.7 0.5 3.8 1.5 2.7 0.5 3.8 1.5 279 13 281 165 8.5 0.1 9 8.3 10/21/2006 17:00:00 2.3 0.4 3.4 0.7 2.3 0.3 3.4 1.5 2.6 0.3 3.4 1.9 270 6 245 165 8.3 0.1 8.5 8.3 10/21/2006 17:10:00 2 0.6 3.4 0.4 1.9 0.7 3.4 0.4 2.2 0.6 4.2 0.7 281 12 283 165 8 0.1 8.5 7.8 10/21/2006 17:20:00 1.7 0.6 2.6 0.4 1.2 0.7 2.3 0.4 1.8 0.5 2.6 0.4 279 15 280 165 7.4 0.1 7.8 7.3 10/21/2006 17:30:00 0.9 0.5 2.3 0.4 0.5 0.4 2.3 0.4 0.9 0.5 2.3 0.4 344 107 102 165 7.3 0.1 7.8 7 10/21/2006 17:40:00 1.7 1.2 4.6 0.4 1.3 1.2 4.6 0.4 1.5 1.2 4.6 0.4 163 38 195 165 6.9 0.1 7.3 6.2 10/21/2006 17:50:00 3.2 0.5 4.6 1.9 2.9 0.5 4.2 1.5 3.2 0.4 4.2 2.3 170 9 181 165 6.6 0 7 6.2 10/21/2006 18:00:00 1.9 0.8 4.2 0.4 1.4 1 3.8 0.4 1.9 0.7 4.2 0.4 188 29 194 165 6.2 0.2 6.7 5.7 10/21/2006 18:10:00 3.2 0.6 4.6 1.5 3.1 0.7 4.6 0.7 3.1 0.7 4.6 1.5 158 30 159 165 6.2 0 6.7 5.7 10/21/2006 18:20:00 2.3 1 4.6 0.4 2.2 1.1 4.6 0.4 2.7 0.7 4.2 0.7 140 29 114 165 5.9 0.1 6.2 5.5 10/21/2006 18:30:00 3.2 1.1 5.7 1.1 3.1 1.1 5.7 0.7 3.1 1.1 6.8 0.4 185 22 186 165 5.7 0 6 5.5 10/21/2006 18:40:00 3.1 1.2 6.1 0.4 3.1 1.2 6.1 0.4 3.1 1 5.7 1.1 193 13 194 165 5.6 0.1 6 5 10/21/2006 18:50:00 3.5 0.9 6.5 2.3 3.7 0.9 6.5 2.6 3.7 0.8 6.1 2.3 207 5 219 165 5.6 0 6 5 10/21/2006 19:00:00 5.2 1.1 8 3 5.3 1.2 8 3 4.9 1.1 7.2 2.6 204 15 212 165 5.4 0.2 6 5 10/21/2006 19:10:00 4.1 0.5 5.3 3 4.1 0.5 4.9 3 4 0.6 5.3 2.3 188 11 187 165 5.1 0.1 5.5 4.5 10/21/2006 19:20:00 5.5 0.7 7.6 4.2 5.4 0.8 8 4.2 5.5 0.6 8.4 4.2 188 7 200 165 5 0 5.2 4.5 10/21/2006 19:30:00 7 0.6 8.4 5.3 7.1 0.6 8.4 5.3 7.1 0.7 8.8 4.6 204 4 207 165 5 0 5.2 4.8 10/21/2006 19:40:00 6.8 0.6 8.4 5.7 7 0.6 8.8 5.7 7 0.8 8.8 5.3 207 5 214 165 5 0 5.7 4.5 10/21/2006 19:50:00 5.9 0.5 7.2 4.2 5.8 0.5 7.2 4.2 6 0.5 7.2 4.6 194 6 203 165 4.9 0 5.2 4.5 10/21/2006 20:00:00 5.8 0.8 7.6 3.4 5.7 0.8 7.6 3 5.9 0.8 9.1 3.4 187 8 197 165 4.9 0 5.2 4.5 10/21/2006 20:10:00 5.5 1 6.8 2.6 5.6 1 7.2 3 5.4 1.2 7.6 3 202 9 191 165 4.8 0.1 5 4.3 10/21/2006 20:20:00 6.8 1.1 9.1 3.8 6.8 1.1 9.1 3.8 7 1.1 9.5 4.2 193 6 192 165 4.8 0 5.2 4.5 10/21/2006 20:30:00 6.1 0.8 8 3.8 6.1 0.8 8 3.8 6.3 0.7 8.4 4.6 193 8 193 165 4.9 0 5.2 4.5 10/21/2006 20:40:00 7 0.9 9.1 4.9 6.9 0.8 8.8 4.9 7.2 0.9 9.1 5.7 187 7 197 165 4.9 0 5.5 4.8 10/21/2006 20:50:00 6.7 1.2 9.5 4.6 6.6 1.1 9.5 4.6 6.9 1.2 9.5 4.6 186 9 186 165 4.9 0 5.2 4.8 10/21/2006 21:00:00 5.2 0.5 6.8 4.2 5.2 0.5 6.8 4.2 5.3 0.5 6.5 4.2 191 6 201 165 4.9 0 5.2 4.8 10/21/2006 21:10:00 4.9 0.5 6.1 3.4 4.9 0.5 6.1 3.4 5.1 0.5 6.5 3.4 181 11 182 165 4.8 0 5 4.5 10/21/2006 21:20:00 6.7 1.8 11.1 3.8 6.6 1.7 10.7 3.8 6.8 1.7 11.5 3.4 171 13 171 165 4.9 0 5.2 4.8 10/21/2006 21:30:00 9.7 1.1 12.2 6.8 9.5 1.1 12.2 6.8 9.8 1.1 12.2 7.2 183 7 186 165 5.1 0 5.2 5 10/21/2006 21:40:00 8.6 1 11.5 6.1 8.4 0.9 11.1 6.1 8.7 1 11.8 6.1 181 9 188 165 5 0 5.5 4.8 10/21/2006 21:50:00 6.5 0.7 8.4 4.6 6.3 0.8 8 4.6 6.7 0.8 8.4 4.9 169 10 165 165 4.9 0.1 5.2 4.5 10/21/2006 22:00:00 6.5 0.6 8 5.3 6.4 0.6 7.6 5.3 6.7 0.6 8.4 5.3 174 5 179 165 4.7 0.1 5 4.3 10/21/2006 22:10:00 6.7 0.5 8 5.3 6.5 0.5 7.6 5.3 6.8 0.6 8 4.9 168 4 165 165 4.7 0.1 5 4.5 10/21/2006 22:20:00 5.8 0.6 7.6 4.6 5.6 0.6 7.2 4.6 5.9 0.6 7.6 4.6 170 6 182 165 4.6 0.1 5 4.3 10/21/2006 22:30:00 8.7 2.2 12.6 4.9 8.5 2.1 12.2 4.9 8.9 2.3 13 4.9 168 13 178 165 4.7 0.1 5 4.3 10/21/2006 22:40:00 10.6 1.3 14.1 8 10.3 1.3 13.7 8 10.8 1.3 13.7 8.4 167 9 155 165 4.6 0.2 5 4.3 10/21/2006 22:50:00 10.9 0.8 13.3 8.8 10.8 0.8 12.6 8.8 11.1 0.8 13 8.8 166 13 164 165 4 0.1 4.8 3.5 10/21/2006 23:00:00 9.9 0.7 11.8 7.6 9.7 0.7 11.8 7.2 10.2 0.8 11.8 7.2 170 6 165 165 3.8 0 4.3 3.5 10/21/2006 23:10:00 9.1 0.5 10.7 7.6 9 0.5 10.7 7.2 9.2 0.7 11.5 7.2 168 4 166 165 3.6 0.1 4 3.3 10/21/2006 23:20:00 8.8 0.4 9.5 6.8 8.7 0.4 9.5 7.2 9 0.5 10.3 6.8 166 8 173 165 3.5 0.1 3.8 3 10/21/2006 23:30:00 7.7 0.6 9.1 6.1 7.7 0.5 9.1 6.1 8 0.6 9.5 5.7 164 3 166 165 3.4 0.2 3.5 2.8 10/21/2006 23:40:00 7.3 0.4 8.4 6.1 7.2 0.4 8.4 6.5 7.3 0.4 8.4 5.7 163 10 162 165 3.3 0.1 3.5 2.8 10/21/2006 23:50:00 6.8 0.8 8.4 4.6 6.7 0.8 8.4 4.2 6.9 0.8 8.4 4.6 158 3 157 165 3.4 0.1 3.5 2.8 10/22/2006 00:00:00 5.7 0.5 6.8 4.2 5.6 0.5 6.8 4.2 5.8 0.6 7.2 4.6 153 6 154 165 3.3 0 3.5 2.6 10/22/2006 00:10:00 7 0.5 8.8 5.7 6.9 0.5 8.4 5.7 7.1 0.6 8.8 5.3 145 9 152 165 3.2 0 3.5 3 10/22/2006 00:20:00 6.2 0.6 7.6 4.6 6.1 0.6 7.6 4.6 6.3 0.6 7.6 4.6 152 5 153 165 3.2 0 3.5 3 10/22/2006 00:30:00 4.4 0.8 6.5 3 4.3 0.7 6.5 2.6 4.3 0.7 6.1 3 147 7 154 165 3.2 0 3.5 3 10/22/2006 00:40:00 3.9 0.8 6.1 2.3 3.8 0.8 6.1 2.3 4 0.8 6.1 2.3 143 11 145 165 3.4 0 3.5 3.3 10/22/2006 00:50:00 5.6 1.7 8.4 1.9 5.5 1.7 8.4 1.9 5.6 1.6 8.4 2.6 133 10 122 165 3.6 0.1 3.8 3 10/22/2006 01:00:00 4.9 1.3 7.6 1.9 4.8 1.5 7.6 1.5 4.7 1.3 7.2 1.5 123 9 114 165 3.9 0.1 4.3 3.3 10/22/2006 01:10:00 5.8 0.5 6.8 4.6 5.9 0.5 6.8 4.9 5.7 0.6 7.2 4.2 118 3 114 165 4 0.1 4.3 3.5 10/22/2006 01:20:00 6.3 1 8 4.6 6.4 0.9 8.4 4.6 6.1 1 8.8 3.8 108 6 102 165 4.2 0.1 4.5 3.5 10/22/2006 01:30:00 6.7 1 8.8 4.2 6.9 1 9.5 3.8 6.5 1 9.1 4.6 109 8 102 165 4.6 0.2 5 3.8 10/22/2006 01:40:00 3.2 0.9 5.3 0.7 2.9 1.1 5.7 0.7 3.4 0.8 5.7 1.5 42 39 111 165 4.6 0.3 5.2 3.8 10/22/2006 01:50:00 3.5 1 5.3 1.5 2.5 1 4.2 0.7 3.8 1 5.7 1.9 11 7 7 165 4.1 0 4.3 3.8 10/22/2006 02:00:00 1 0.7 3 0.4 0.6 0.6 3 0.4 1.3 0.8 3.4 0.4 20 58 17 165 4.2 0 4.5 4 10/22/2006 02:10:00 0.8 0.4 1.9 0.4 0.4 0.2 1.5 0.4 0.9 0.4 1.9 0.4 155 7 161 165 4.5 0 4.8 4.3 10/22/2006 02:20:00 0.5 0.3 1.9 0.4 0.4 0.3 1.9 0.4 0.5 0.3 1.9 0.4 205 35 254 165 4.6 0.1 4.8 4 10/22/2006 02:30:00 1.3 0.6 3 0.4 1.3 0.7 3.4 0.4 1.5 0.5 3 0.4 257 15 257 165 4.5 0 4.8 4.3 10/22/2006 02:40:00 1.9 0.7 3.4 0.4 1.9 0.8 3.8 0.4 2.2 0.6 3.8 1.1 248 13 239 165 4.1 0.1 4.5 3.8 10/22/2006 02:50:00 2.7 0.6 4.2 1.1 2.9 0.4 4.2 1.9 3.2 0.4 4.6 2.3 248 9 241 165 3.9 0 4.3 3.3 10/22/2006 03:00:00 2.2 0.5 3.4 1.1 2.5 0.5 3.4 1.5 2.8 0.4 3.8 1.9 263 13 267 165 3.9 0 4.3 3.5 10/22/2006 03:10:00 2.3 0.5 3.8 1.5 2.6 0.4 3.8 1.9 3 0.5 4.6 1.5 251 7 249 165 3.9 0 4.3 3.3 10/22/2006 03:20:00 3.2 0.6 4.9 1.5 3.6 0.4 4.6 2.6 4 0.4 4.9 3 255 8 250 165 3.6 0.1 3.8 3 10/22/2006 03:30:00 3.4 0.6 4.6 1.5 3.7 0.4 4.6 2.6 4 0.5 5.3 2.3 270 10 283 165 3.6 0.1 4 3.3 10/22/2006 03:40:00 3.8 0.5 4.6 2.3 4 0.4 4.9 2.6 4.3 0.5 5.3 2.3 280 8 276 165 3.7 0.1 4.3 3.5 10/22/2006 03:50:00 4.2 0.5 5.3 2.6 4.3 0.5 5.3 2.6 4.1 0.7 5.7 2.3 291 6 284 165 3.7 0 4 3.5 10/22/2006 04:00:00 4.5 0.5 5.7 3.4 4.6 0.5 5.7 3.4 3.9 0.5 5.3 2.6 296 5 296 165 3.9 0 4.3 3.8 10/22/2006 04:10:00 5.1 0.7 6.5 3.4 5.2 0.7 6.8 3.8 4.1 0.8 6.1 2.6 304 5 304 165 4 0 4.3 3.8 10/22/2006 04:20:00 3.9 0.4 4.9 3 3.9 0.4 4.9 3 3.4 0.4 4.6 2.3 304 7 297 165 3.8 0.1 4 3.5 10/22/2006 04:30:00 4.2 0.7 6.1 3 4.1 0.7 6.1 3 4.1 0.6 5.3 3 315 7 305 165 3.5 0 3.8 3.3 10/22/2006 04:40:00 5.2 0.8 7.2 3.4 5.1 0.8 7.2 3.4 4.5 0.6 6.5 2.6 309 7 302 165 3.6 0.1 3.8 3.3 10/22/2006 04:50:00 5.2 0.6 7.2 3.8 5.1 0.6 7.6 3.8 4.8 0.5 6.8 3 313 8 302 165 3.2 0 3.5 3 10/22/2006 05:00:00 5.6 1.2 8 3.4 5.6 1.2 8.4 3 4.9 0.6 7.2 3 312 13 298 165 3.3 0 3.8 3.3 10/22/2006 05:10:00 7.8 0.7 9.9 5.3 7.7 0.7 9.9 5.3 6 0.9 8.4 4.2 300 3 304 165 3.6 0 3.8 3.5 10/22/2006 05:20:00 8.3 0.6 9.5 6.8 8.1 0.5 9.5 6.8 6.7 0.7 8.4 3.4 304 5 302 165 3.5 0 3.5 3.3 10/22/2006 05:30:00 8.4 0.6 10.7 6.8 8.3 0.6 9.9 6.8 7 0.7 8.8 5.3 308 5 300 165 3.5 0 3.8 3.3 10/22/2006 05:40:00 9.5 0.9 12.6 6.8 9.4 0.9 11.8 7.2 8 0.9 10.3 5.7 308 5 307 165 3.6 0 3.8 3.5 10/22/2006 05:50:00 9.2 0.9 12.2 7.6 9.2 0.9 11.8 7.6 7.9 1.3 11.1 5.3 307 7 307 165 3.8 0 4 3.5 10/22/2006 06:00:00 10 1 13.7 7.2 9.9 1 13.3 7.2 7.9 1 11.1 5.7 301 6 298 165 3.8 0 4.3 3.5 10/22/2006 06:10:00 11.8 1.2 14.9 8.8 11.7 1.2 14.5 8.8 9.9 1.8 13.7 6.5 308 7 307 165 3.8 0.1 4.3 3.5 10/22/2006 06:20:00 12.7 1.5 16.8 8.8 12.7 1.5 16.4 8.8 10.1 1.3 13.7 6.8 303 7 298 165 3.5 0 3.8 3.5 10/22/2006 06:30:00 12.7 1.1 16.1 9.5 12.6 1.1 16.1 9.5 10 1.4 16.4 7.2 301 7 282 165 3.5 0 3.5 3.3 10/22/2006 06:40:00 12.7 1.3 15.3 8.8 12.6 1.3 15.3 8.8 10.3 1.3 14.1 6.8 302 8 300 165 3.6 0 3.8 3.5 10/22/2006 06:50:00 11.1 1.3 15.3 7.2 11.1 1.3 15.3 7.2 9.2 1.5 12.6 5.7 301 8 297 165 3.7 0 3.8 3.5 10/22/2006 07:00:00 12.1 1.4 16.4 8.8 12 1.4 16.1 8.4 10.5 1.7 16.1 6.8 309 6 322 165 3.8 0 4.3 3.5 10/22/2006 07:10:00 13.8 1.3 18.3 9.9 13.6 1.3 18.7 9.5 12.5 1.6 16.8 8.4 312 7 309 165 4 0 4.3 3.8 10/22/2006 07:20:00 14.2 1.4 19.5 10.3 13.9 1.5 18.7 10.3 13 1.9 18.3 8 314 8 313 165 4.1 0 4.3 3.8 10/22/2006 07:30:00 15.2 1.2 19.1 11.5 15 1.2 18.7 11.8 13.9 1.5 18.7 9.5 313 7 307 165 4.1 0 4.5 4 10/22/2006 07:40:00 13.8 1.7 17.9 9.1 13.7 1.7 17.2 9.5 12.6 1.7 16.8 8 312 7 305 165 4.2 0 4.5 4.3 10/22/2006 07:50:00 13 1.3 16.8 9.5 12.9 1.2 16.4 9.9 11.3 1.7 16.4 7.2 310 6 315 165 4.1 0 4.5 4 10/22/2006 08:00:00 11.8 1.6 15.6 8 11.7 1.6 15.3 7.6 10.3 1.6 14.1 6.8 309 6 307 165 4.1 0 4.5 4 10/22/2006 08:10:00 12.9 1.7 16.4 8.8 12.8 1.7 16.4 8.8 10.7 1.7 15.3 7.2 307 7 317 165 4.1 0 4.3 4 10/22/2006 08:20:00 14.7 1.4 17.9 11.5 14.6 1.5 17.9 11.1 12.1 1.6 16.1 6.5 306 6 308 165 4.1 0 4.3 4 10/22/2006 08:30:00 14.5 1.3 17.6 11.1 14.3 1.3 17.6 10.7 11.6 1.5 16.1 8 305 7 302 165 4.1 0 4.5 4 10/22/2006 08:40:00 14.8 1.3 17.9 11.5 14.6 1.3 17.6 11.5 11.8 1.3 14.9 8 304 7 308 165 4.1 0 4.5 4 10/22/2006 08:50:00 15.2 1.3 19.5 11.8 15 1.3 18.7 11.8 12.5 1.5 16.8 8.4 307 6 310 165 4.5 0.1 4.8 4.3 10/22/2006 09:00:00 14.9 1.5 18.3 11.5 14.8 1.5 18.3 11.1 13.2 1.8 17.2 9.1 311 7 305 165 4.7 0.1 5 4.5 10/22/2006 09:10:00 15.4 1.4 18.3 11.5 15.2 1.5 18.3 11.1 13.2 1.7 17.6 9.1 309 7 307 165 4.4 0 4.8 4.3 10/22/2006 09:20:00 15.7 1.3 19.1 12.6 15.5 1.3 19.1 12.2 13.2 1.5 17.2 9.1 308 6 306 165 4.4 0 4.5 4.3 10/22/2006 09:30:00 13.1 1.5 16.4 8 12.9 1.4 16.1 8.4 12 1.5 14.9 6.8 315 8 302 165 4.5 0 4.8 4.3 10/22/2006 09:40:00 11.2 1.5 14.9 7.2 11 1.5 14.9 7.6 10 1.5 14.5 6.8 313 8 306 165 4.7 0 5 4.5 10/22/2006 09:50:00 11.5 1.6 15.6 8 11.4 1.5 15.3 8.4 10.7 1.3 14.1 7.6 314 8 296 165 4.8 0 5 4.8 10/22/2006 10:00:00 11.4 1.2 14.5 8.4 11.3 1.2 14.1 8 10 1.2 13 7.2 311 7 301 165 4.9 0 5 4.8 10/22/2006 10:10:00 11 1.3 14.9 8.4 10.9 1.3 15.3 8.4 10 1.3 13.7 6.8 313 9 307 165 4.9 0 5 4.8 10/22/2006 10:20:00 11.6 1.3 14.5 8.4 11.5 1.3 14.5 8 10.4 1.2 13.7 7.2 311 6 301 165 4.9 0 5.2 4.8 10/22/2006 10:30:00 10.8 1.2 14.1 7.6 10.7 1.2 13.7 7.6 9.5 1.3 13 6.1 308 6 315 165 5 0 5.2 4.5 10/22/2006 10:40:00 11.1 1.1 14.1 8.4 11.1 1.1 14.1 8.4 9.1 1 11.8 6.5 305 6 300 165 5 0.1 5.5 4.5 10/22/2006 10:50:00 11.3 1 13.7 9.1 11.2 1 13.7 9.1 9.7 1.1 13.3 6.5 307 6 302 165 5.5 0.2 5.7 4.8 10/22/2006 11:00:00 10.9 0.9 13.3 8.8 10.8 0.9 13.3 8.8 9.5 1.3 12.6 6.8 310 6 309 165 5.2 0.2 5.7 4.8 10/22/2006 11:10:00 10.5 0.9 12.6 8.4 10.4 0.9 12.6 8 8.7 1.2 12.2 5.7 305 8 290 165 5.7 0.1 6 5.2 10/22/2006 11:20:00 11.1 0.9 13.7 8.8 11.1 0.9 13.3 9.1 9.3 1.1 12.2 6.5 307 5 302 165 5.5 0 5.7 5.2 10/22/2006 11:30:00 11.3 0.7 13.3 9.1 11.2 0.7 13 9.1 9.8 1.2 13 6.5 309 6 309 165 5.5 0 5.7 5.2 10/22/2006 11:40:00 11.9 0.9 13.7 9.1 11.8 0.9 13.3 8.8 10 1.2 13 7.2 309 5 297 165 5.4 0 5.7 5 10/22/2006 11:50:00 12.3 0.9 14.1 9.9 12.1 0.8 14.1 9.9 11.9 0.8 14.1 9.5 315 4 312 165 5.4 0.2 5.7 5 10/22/2006 12:00:00 11.2 1.1 14.5 8 11.1 1.1 14.1 8.4 10.4 1.1 14.5 8 314 6 325 165 5.6 0.2 6 5.2 10/22/2006 12:10:00 10.8 1 12.6 8 10.7 1 12.6 8 9.4 1 11.8 6.8 311 5 310 165 6.2 0.3 6.7 5.5 10/22/2006 12:20:00 10.7 0.8 12.2 8.4 10.7 0.8 12.2 8 10.2 0.9 12.6 8 313 5 315 165 6.1 0.1 6.5 5.7 10/22/2006 12:30:00 9.4 0.7 10.7 7.2 9.3 0.7 11.1 6.8 8.1 1.2 10.7 5.3 310 6 312 165 5.9 0.1 6.2 5.5 10/22/2006 12:40:00 9.4 0.8 12.6 6.8 9.4 0.9 13 6.8 9.3 0.9 12.6 6.8 318 5 322 165 5.6 0 5.7 4.8 10/22/2006 12:50:00 8.4 0.7 9.9 5.7 8.4 0.7 9.5 5.7 6.8 0.8 8.8 5.3 304 5 302 165 5.2 0.2 5.7 4.8 10/22/2006 13:00:00 9.4 1 11.1 6.1 9.3 1 11.1 6.1 8.2 1 10.3 5.7 309 4 308 165 4.8 0 5 4.5 10/22/2006 13:10:00 7.8 0.7 9.9 6.1 7.8 0.7 9.9 6.1 7.2 0.8 9.5 4.9 313 5 318 165 4.9 0.2 5.2 4.3 10/22/2006 13:20:00 7.8 0.8 9.5 6.1 7.7 0.7 9.5 6.5 7.7 0.7 9.9 5.3 318 5 312 165 5.3 0.3 6 4.8 10/22/2006 13:30:00 7.3 0.7 9.1 5.7 7.3 0.6 8.8 6.1 6.9 0.8 8.8 4.6 315 5 311 165 6.1 0.1 6.5 5.5 10/22/2006 13:40:00 8.3 0.9 10.3 6.1 8.2 0.9 10.3 6.1 7.5 0.8 9.5 4.9 311 5 308 165 6.6 0.2 7.3 6.2 10/22/2006 13:50:00 7.7 0.8 9.5 5.7 7.7 0.7 9.5 5.7 7 0.9 9.5 4.6 310 8 305 165 6.6 0.2 7.3 6 10/22/2006 14:00:00 8.1 1 10.3 5.3 8 1 9.9 5.7 7.5 1 9.9 4.9 313 8 314 165 6.4 0 6.7 6 10/22/2006 14:10:00 7.5 0.8 10.3 5.3 7.5 0.8 10.3 5.7 6.9 1 9.1 4.2 314 8 313 165 6.8 0.2 7.3 6.2 10/22/2006 14:20:00 6.8 1 8.8 4.9 6.6 1 8.8 4.6 5.8 0.8 7.6 4.2 309 8 296 165 6.5 0.4 7.3 5.7 10/22/2006 14:30:00 7.7 0.7 9.9 5.7 7.6 0.7 9.5 5.7 6.3 0.7 8.8 4.6 306 5 308 165 6.6 0.2 7 6 10/22/2006 14:40:00 5.7 0.9 8 3.8 5.6 0.9 7.6 3.4 5 1.1 7.2 2.6 307 7 312 165 6.7 0.2 7.3 6.2 10/22/2006 14:50:00 5.1 0.9 7.2 2.6 5 0.9 6.8 2.6 4.3 0.9 6.5 2.3 305 9 294 165 6.1 0 6.5 5.7 10/22/2006 15:00:00 4.2 1 6.1 0.7 4.3 0.8 6.1 2.6 3.7 0.6 5.3 1.9 290 12 294 165 6.1 0.1 6.5 5.7 10/22/2006 15:10:00 3.9 0.7 5.3 2.3 4.5 0.5 5.7 3.4 4.5 0.5 5.7 3 271 5 273 165 6.2 0 6.7 5.7 10/22/2006 15:20:00 4.6 0.6 6.1 3.4 4.7 0.6 5.7 3.4 4.4 0.7 6.5 2.6 285 5 278 165 6 0 6.2 5.7 10/22/2006 15:30:00 5.6 0.4 6.8 4.2 5.6 0.4 6.5 4.6 4.5 0.7 6.8 3 296 4 295 165 5.9 0.1 6.2 5.5 10/22/2006 15:40:00 5.6 0.4 6.8 4.2 5.6 0.4 6.5 4.2 4.5 0.6 6.8 3 299 5 300 165 6.1 0 6.2 5.7 10/22/2006 15:50:00 5.9 0.3 6.8 4.9 5.9 0.3 6.8 4.9 4.6 0.5 6.1 3 301 5 303 165 6.1 0.1 6.5 5.5 10/22/2006 16:00:00 5.2 0.5 6.5 3.8 5.1 0.5 6.5 3.8 4.4 0.7 6.5 3 295 6 294 165 5.8 0.1 6 5.5 10/22/2006 16:10:00 4.8 0.5 6.5 3.4 4.8 0.5 6.5 3.8 4 0.6 5.7 2.6 295 4 295 165 6.1 0.1 6.2 5.7 10/22/2006 16:20:00 4.6 0.4 6.1 3.4 4.6 0.4 5.7 3.4 4 0.5 4.9 2.6 306 6 307 165 6.3 0.2 6.7 5.7 10/22/2006 16:30:00 3.8 0.6 5.3 2.6 3.8 0.6 5.3 2.6 3.8 0.6 5.3 2.3 312 5 310 165 7.1 0.2 7.5 6.5 10/22/2006 16:40:00 3.9 0.4 4.9 2.6 3.8 0.4 4.9 2.3 3.7 0.5 4.9 2.6 314 8 304 165 6.9 0.3 7.5 6.2 10/22/2006 16:50:00 4.6 0.7 6.1 3 4.4 0.7 6.1 2.6 4 0.5 5.3 2.6 312 10 296 165 5.7 0.2 6.2 5.5 10/22/2006 17:00:00 5 0.4 6.1 3.8 4.7 0.5 5.7 3.4 4 0.5 5.3 2.6 306 5 304 165 5.3 0.1 5.7 5 10/22/2006 17:10:00 4.8 0.5 5.7 3.8 4.7 0.4 5.7 3.8 4.3 0.4 5.3 3.4 310 5 304 165 5.1 0.1 5.5 4.8 10/22/2006 17:20:00 4.7 0.5 6.1 3.8 4.5 0.4 5.7 3.4 4.8 0.4 6.1 3.8 319 6 320 165 4.7 0.1 5 4.3 10/22/2006 17:30:00 4.5 0.4 5.7 3 4.2 0.4 5.3 2.6 4.4 0.4 5.3 3 322 6 309 165 4.4 0 4.8 3.8 10/22/2006 17:40:00 4.6 0.4 5.3 3.4 4.3 0.4 5.3 3 4.4 0.4 5.3 3 325 10 312 165 4.1 0.1 4.5 3.5 10/22/2006 17:50:00 5.3 0.5 6.5 4.2 5.2 0.6 6.8 3.8 5.3 0.5 6.5 4.2 341 6 332 165 4.1 0.1 4.5 3.5 10/22/2006 18:00:00 5.7 0.5 7.2 4.6 5.6 0.5 7.2 4.6 5.6 0.4 6.8 4.6 339 5 349 165 4 0 4.5 3.5 10/22/2006 18:10:00 6.4 0.4 7.6 5.3 6.6 0.5 8 5.3 6.5 0.5 7.6 5.3 340 4 346 165 3.8 0 4 3.5 10/22/2006 18:20:00 6.7 0.5 7.6 5.7 6.7 0.6 8 4.6 6.7 0.5 8 5.3 342 5 347 165 3.8 0 4 3.5 10/22/2006 18:30:00 6.1 0.6 7.6 4.6 6.2 0.6 7.6 4.9 6.3 0.6 7.6 4.6 338 6 336 165 3.8 0 4.3 3.5 10/22/2006 18:40:00 6.5 0.5 7.6 5.3 6.5 0.5 8 5.3 6.2 0.9 7.6 3.8 321 11 347 165 4.1 0 4.5 3.8 10/22/2006 18:50:00 5.6 0.4 6.8 4.9 5.6 0.4 6.8 4.9 5.3 0.5 6.5 4.2 311 3 314 165 4.1 0 4.3 3.8 10/22/2006 19:00:00 5.6 0.5 6.8 4.6 5.5 0.5 6.8 4.6 5 0.4 6.5 3.8 309 4 309 165 4 0 4.3 3.5 10/22/2006 19:10:00 6.2 0.5 7.6 4.6 6.2 0.5 7.6 4.6 5.3 0.7 6.5 3 308 5 303 165 3.8 0 4 3.5 10/22/2006 19:20:00 5.9 0.4 7.2 4.9 5.8 0.4 6.8 4.9 5.6 0.5 6.8 4.2 317 8 314 165 4 0 4.3 3.5 10/22/2006 19:30:00 5 0.8 6.8 3 4.9 0.7 6.8 3 4.9 0.7 7.2 3.8 323 9 315 165 3.8 0.1 4.3 3.3 10/22/2006 19:40:00 3.5 0.6 5.3 1.5 3.4 0.6 5.3 1.9 3.6 0.5 4.9 2.6 329 12 309 165 3.5 0.1 3.8 3 10/22/2006 19:50:00 4.1 0.9 6.1 2.3 4.1 0.9 6.1 2.3 4.3 0.9 6.1 2.6 341 7 349 165 3.7 0 4 3.3 10/22/2006 20:00:00 5.7 0.5 6.8 4.6 5.7 0.7 7.2 2.6 5.9 0.5 7.2 4.6 345 5 347 165 3.8 0 4.3 3.5 10/22/2006 20:10:00 4.5 0.5 6.1 3.4 4.5 0.5 6.5 3.4 4.8 0.5 6.5 3.4 336 8 344 165 3.9 0.1 4.3 3.3 10/22/2006 20:20:00 3.4 0.6 5.7 2.3 3.1 0.7 5.7 1.1 3.9 0.5 5.7 2.6 347 8 351 165 4 0 4.5 3.5 10/22/2006 20:30:00 4.5 1.1 6.5 2.3 3.7 1.2 6.5 1.5 4.5 0.8 6.1 3 350 7 344 165 4 0 4.3 3.5 10/22/2006 20:40:00 4.4 0.5 5.7 3 4.3 0.5 5.7 2.6 4.7 0.5 6.1 3.4 343 6 349 165 3.8 0 4 3.5 10/22/2006 20:50:00 3.8 0.5 4.9 2.3 3.8 0.5 5.3 2.3 3.9 0.5 5.3 2.6 329 9 343 165 3.9 0 4.3 3.8 10/22/2006 21:00:00 3.7 0.6 5.3 2.6 3.8 0.6 5.7 2.6 4 0.6 5.7 2.6 325 9 349 165 4.3 0 4.5 4 10/22/2006 21:10:00 4.2 0.6 5.7 2.6 4.2 0.6 5.3 2.6 4.4 0.6 5.3 3 320 7 334 165 4.4 0 4.5 3.8 10/22/2006 21:20:00 5 0.7 6.5 3.8 5 0.6 6.5 3.8 5.1 0.6 6.5 3.8 326 8 310 165 4.1 0.1 4.5 4 10/22/2006 21:30:00 4.4 0.6 5.7 2.6 4.4 0.7 6.1 1.9 4.6 0.5 6.1 3.4 333 9 323 165 4.4 0 4.8 4.3 10/22/2006 21:40:00 3.7 0.7 5.3 2.3 3.7 0.8 4.9 1.1 4 0.6 5.3 2.6 327 14 315 165 4.3 0 4.5 3.8 10/22/2006 21:50:00 4.1 0.8 5.7 2.6 4.1 0.7 5.3 2.6 4.2 0.7 5.7 2.6 317 7 330 165 4.4 0 4.8 3.8 10/22/2006 22:00:00 3.2 0.5 4.2 1.9 3.3 0.5 4.6 1.9 3.5 0.5 4.6 1.9 325 9 330 165 4.3 0 4.8 4.3 10/22/2006 22:10:00 2.9 0.6 3.8 1.1 2.9 0.6 4.2 1.1 3 0.5 4.2 1.9 320 11 313 165 4.3 0 4.5 4.3 10/22/2006 22:20:00 2.5 0.7 4.2 0.7 2.6 0.7 4.2 0.7 2.7 0.5 3.8 1.9 311 9 296 165 4.3 0 4.5 4.3 10/22/2006 22:30:00 2.8 0.8 5.3 1.1 2.8 0.8 5.3 1.1 3.1 0.6 5.3 1.9 309 18 329 165 4.5 0.1 5 4.3 10/22/2006 22:40:00 3.1 1 5.3 1.1 3.2 0.9 4.9 1.1 3.4 0.9 6.5 1.5 313 22 330 165 4.8 0 5 4.8 10/22/2006 22:50:00 2.6 0.9 4.6 1.1 2.6 1 4.6 0.7 2.8 0.9 4.9 1.5 310 24 340 165 4.9 0 5.2 4.8 10/22/2006 23:00:00 1.9 0.5 3 0.7 1.9 0.5 3.4 0.7 2.1 0.5 3.4 1.1 295 8 292 165 4.7 0.1 5 4.5 10/22/2006 23:10:00 1.3 1 3.8 0.4 1.2 1 3.4 0.4 1.8 0.8 3.8 0.4 293 16 294 165 4.8 0 5 4.5 10/22/2006 23:20:00 1.3 0.6 3.4 0.4 1.2 0.6 3 0.4 1.7 0.5 3 0.4 314 19 312 165 4.8 0.1 5 4.5 10/22/2006 23:30:00 2.7 1.1 5.7 0.7 2.6 1.1 5.7 0.4 2.6 1 5.3 0.7 316 21 337 165 4.6 0 5 4.5 10/22/2006 23:40:00 3.2 0.9 5.3 1.5 3.1 0.9 5.3 1.1 3 0.8 4.9 1.9 305 17 329 165 4.5 0 4.8 4.3 10/22/2006 23:50:00 5.1 1 7.6 3 4.9 1.1 7.6 2.6 4.5 1.1 7.2 2.3 334 11 343 165 4.5 0 4.8 4.3 10/23/2006 00:00:00 5.8 1 8.4 3.4 5.6 1 8.4 2.6 5.5 1.1 8.8 2.6 334 11 347 165 4.7 0 5 4.5 10/23/2006 00:10:00 6.6 0.8 8.8 4.6 6.4 1.1 8.8 3 6.1 1 8.8 3.8 346 7 337 165 4.7 0 5 4.8 10/23/2006 00:20:00 6.5 1 8.8 3.4 6.3 1 9.1 3.4 6 1.1 8.8 2.6 334 12 334 165 4.8 0 5 4.8 10/23/2006 00:30:00 8 1.3 11.5 4.9 7.9 1.5 12.2 4.6 7.6 1.3 11.5 4.9 337 10 349 165 4.8 0 5 4.5 10/23/2006 00:40:00 7.4 1.5 11.5 4.2 7 1.5 10.7 3.4 7 1.6 10.7 3.8 341 13 351 165 4.8 0.1 5 4.5 10/23/2006 00:50:00 9.4 1.4 12.2 5.7 9.3 1.4 12.2 5.7 9.3 1.4 13 5.7 335 9 340 165 4.8 0 5 4.8 10/23/2006 01:00:00 9.7 1.2 13.3 6.5 9.6 1.2 13.3 6.1 9.5 1.3 13 6.5 340 7 342 165 4.9 0 5 4.5 10/23/2006 01:10:00 8.9 1 11.8 5.7 8.6 1.2 11.5 4.9 8.5 1.1 11.5 5.3 342 10 346 165 4.8 0 5 4.8 10/23/2006 01:20:00 8.8 1.3 12.2 4.9 8.6 1.3 12.6 4.9 8.4 1.3 12.2 5.3 342 8 344 165 4.7 0 5 4.5 10/23/2006 01:30:00 9.6 0.9 13 6.8 9.5 1 13 6.1 9.3 1 12.6 6.8 337 9 325 165 4.6 0 5 4.5 10/23/2006 01:40:00 9.3 1.5 13.3 6.1 9.2 1.6 13.3 6.1 8.9 1.5 13 6.1 337 10 344 165 4.6 0 5 4.5 10/23/2006 01:50:00 10.4 1.1 14.1 6.8 10.4 1.2 13.7 6.8 9.9 1.2 13 6.5 338 7 357 165 4.6 0 4.8 4.5 10/23/2006 02:00:00 8.9 1.7 14.1 4.6 8.7 1.9 14.9 4.6 8.5 1.6 13.3 4.9 338 13 346 165 4.6 0 5 4.5 10/23/2006 02:10:00 7.9 1.3 11.1 4.6 7.9 1.2 11.5 4.6 7.2 1.2 10.3 3.8 314 12 330 165 4.4 0 4.8 4.3 10/23/2006 02:20:00 8.9 1.1 12.2 6.1 8.8 1.1 11.8 6.1 7.2 1.3 10.7 3.8 305 8 302 165 4.1 0.1 4.5 3.8 10/23/2006 02:30:00 7.8 1.3 10.7 3.4 7.7 1.2 10.7 4.2 6.1 1.2 9.5 1.9 305 9 302 165 3.8 0 4.3 3.5 10/23/2006 02:40:00 8.4 1.3 11.1 4.2 8.3 1.2 10.7 4.6 7.1 1.1 9.9 3.4 305 9 305 165 3.6 0 3.8 3.5 10/23/2006 02:50:00 8.6 1.4 11.8 4.6 8.4 1.3 11.5 4.9 7 1.2 10.3 3.8 305 9 298 165 3.7 0 4 3.5 10/23/2006 03:00:00 7.2 1.1 10.7 4.2 7.2 1 11.1 4.2 5.9 1.2 8.8 2.3 315 15 300 165 3.6 0 3.8 3.5 10/23/2006 03:10:00 7.5 1 9.9 4.9 7.5 1 9.9 4.9 6.2 1.2 9.1 3 314 8 310 165 3.6 0 3.8 3.5 10/23/2006 03:20:00 6 0.7 8.4 3.8 5.9 0.7 7.6 3.8 5.7 0.8 7.6 2.6 327 9 321 165 3.7 0.1 4 3.5 10/23/2006 03:30:00 7.2 1.4 12.6 4.2 7.1 1.3 11.8 3.8 7 1.3 10.3 3.8 330 12 355 165 3.8 0.1 4.3 3.5 10/23/2006 03:40:00 8.5 2 14.1 4.9 7.9 1.4 12.2 4.9 8 2 13 4.6 337 17 2 165 4.1 0 4.5 3.8 10/23/2006 03:50:00 6.8 1 9.5 4.2 6.8 1 9.9 4.2 6.1 1.1 9.1 2.3 325 13 322 165 4.1 0 4.5 3.8 10/23/2006 04:00:00 8.5 1.7 13.3 4.9 8.5 1.7 12.6 4.9 7.7 1.8 12.2 3.8 318 13 315 165 4.3 0 4.5 4.3 10/23/2006 04:10:00 9 1.5 13.7 5.3 9 1.5 14.9 5.3 7.7 1.5 12.6 3.8 310 10 314 165 4.4 0 4.8 4.3 10/23/2006 04:20:00 8.8 1.1 11.5 6.1 8.7 1.1 11.8 6.1 7.5 1.3 12.6 3.8 312 9 310 165 4 0 4.5 3.8 10/23/2006 04:30:00 10.3 1 12.6 6.8 10.1 1 12.2 7.2 8.2 1.3 11.1 4.2 304 6 305 165 3.5 0.1 4 3.3 10/23/2006 04:40:00 11.7 0.8 13.7 9.5 11.6 0.8 13.3 9.1 10.2 1.3 13 6.8 309 5 310 165 3.2 0.1 3.5 2.8 10/23/2006 04:50:00 11.4 0.8 13 9.5 11.3 0.8 13 9.5 11.2 0.9 13 8.8 315 4 316 165 3.2 0 3.5 3 10/23/2006 05:00:00 12.3 1.2 15.3 9.9 12.2 1.2 15.3 9.5 11.5 1.2 14.1 7.6 313 6 300 165 3.3 0 3.5 3.3 10/23/2006 05:10:00 12.8 1 14.9 10.7 12.8 0.9 14.9 10.7 12 1 14.5 9.1 314 5 315 165 3.4 0 3.5 3.3 10/23/2006 05:20:00 12 1.2 15.3 8.8 11.9 1.3 14.9 8.4 11.6 1.2 14.9 8 317 6 316 165 3.5 0 3.5 3.3 10/23/2006 05:30:00 10.2 0.9 13 7.2 10.1 0.9 13 7.2 10.1 0.9 12.6 7.2 321 7 305 165 3.4 0 3.5 3.3 10/23/2006 05:40:00 10.2 0.7 12.6 7.6 10 0.7 11.8 8 10.1 0.8 12.2 7.6 322 6 313 165 3.5 0 3.8 3.3 10/23/2006 05:50:00 10.3 1.1 13 7.6 10.2 1.1 13 7.6 9.6 1 11.8 6.1 317 8 305 165 3.5 0 3.5 3.3 10/23/2006 06:00:00 10.8 1.5 14.9 7.6 10.7 1.5 14.5 7.2 10.3 1.4 14.1 7.2 318 7 310 165 3.4 0.1 3.8 3.3 10/23/2006 06:10:00 10.8 1.2 14.5 7.2 10.6 1.2 14.1 6.8 10.4 1.3 14.5 6.8 317 6 317 165 3.5 0 3.8 3.3 10/23/2006 06:20:00 10.9 1.3 14.5 7.6 10.7 1.3 14.1 7.2 10 1.3 13.3 7.2 316 8 310 165 3.5 0 3.8 3.3 10/23/2006 06:30:00 11.8 1.3 15.3 8.8 11.6 1.3 14.9 8.8 11 1.7 14.5 6.8 314 8 315 165 3.5 0 3.8 3.3 10/23/2006 06:40:00 14.1 1.7 17.6 8 13.8 1.7 17.6 8 13 1.8 17.2 7.2 315 6 309 165 3.6 0 3.8 3.5 10/23/2006 06:50:00 16 1.2 19.1 12.6 15.8 1.2 18.7 12.6 14.8 1.5 18.7 9.5 314 6 313 165 3.8 0 3.8 3.5 10/23/2006 07:00:00 15.9 1.5 19.9 11.5 15.7 1.5 19.9 11.5 15 1.8 19.5 11.1 316 6 306 165 3.8 0 4 3.5 10/23/2006 07:10:00 16.3 1 19.5 13.3 16.1 1 19.5 13 15.3 1.2 18.3 11.8 313 5 317 165 3.8 0 4 3.5 10/23/2006 07:20:00 17.3 1.3 20.6 13.3 17 1.3 20.6 13.3 16.1 1.6 19.9 10.3 314 5 307 165 4 0 4.3 3.8 10/23/2006 07:30:00 16.1 1.2 18.7 13.3 15.9 1.3 18.7 13 15.5 1.4 19.9 11.8 319 8 320 165 3.9 0 4.3 3.5 10/23/2006 07:40:00 16.7 1.4 20.6 13.3 16.5 1.4 20.2 13 16.3 1.6 20.6 12.2 321 6 328 165 3.9 0 4.3 3.8 10/23/2006 07:50:00 17.3 1.3 21 13.7 17.1 1.3 20.6 13.3 16.7 1.4 21 11.8 319 9 328 165 3.8 0 4.3 3.8 10/23/2006 08:00:00 16.1 1.6 19.9 12.2 15.9 1.6 19.5 11.8 15.6 1.6 19.9 11.8 323 9 318 165 3.9 0 4.3 3.8 10/23/2006 08:10:00 16.5 1.1 19.1 13 16.2 1.1 18.7 12.2 16.2 1.4 19.9 12.6 321 6 319 165 3.8 0 4.3 3.5 10/23/2006 08:20:00 16.4 1.3 19.5 11.8 16.2 1.3 18.7 11.8 16.2 1.5 19.5 11.1 324 6 321 165 4 0.1 4.5 3.8 10/23/2006 08:30:00 13.5 1.4 16.8 9.5 13.4 1.4 16.8 9.5 13.4 1.5 17.6 9.9 322 7 317 165 4.3 0 4.5 4.3 10/23/2006 08:40:00 10.6 1.3 14.5 7.2 10.5 1.3 14.5 6.8 10.2 1.5 14.1 6.5 318 8 326 165 4.2 0.1 4.5 4 10/23/2006 08:50:00 8.9 1 13 6.5 8.8 1 13 6.1 8.5 1.2 12.6 5.7 314 8 307 165 4.2 0 4.5 4.3 10/23/2006 09:00:00 8.7 1.1 11.1 4.9 8.7 1.1 11.5 5.3 7.8 1.1 10.7 4.2 311 9 319 165 4.5 0 4.8 4.3 10/23/2006 09:10:00 10.2 1.2 13.3 6.5 10.1 1.2 13 6.5 9 1.4 12.2 4.2 309 7 304 165 4.8 0 5 4.5 10/23/2006 09:20:00 8.4 1.2 11.8 5.7 8.4 1.1 11.8 5.7 7.5 1.1 11.1 4.9 310 9 310 165 5 0.1 5.2 4.5 10/23/2006 09:30:00 9.1 1.2 12.2 6.1 9 1.2 12.2 5.7 8.5 1.4 11.5 4.9 313 8 312 165 5.2 0.1 5.5 4.8 10/23/2006 09:40:00 9.4 1.5 13 5.3 9.3 1.5 13 5.3 8.3 1.7 12.2 3.8 310 11 332 165 5.3 0.1 5.7 5 10/23/2006 09:50:00 8.3 1.4 12.2 4.6 8.2 1.3 11.8 4.6 7.8 1.3 12.2 4.6 315 12 321 165 5.6 0.1 5.7 5.2 10/23/2006 10:00:00 8.6 1.6 13 5.3 8.6 1.5 12.2 4.9 7.8 1.6 11.5 4.6 310 9 307 165 5.6 0 5.7 5.5 10/23/2006 10:10:00 9.4 1 11.8 6.1 9.3 1 12.2 6.5 8.4 1.2 12.2 5.7 313 8 312 165 5.6 0 5.7 5.5 10/23/2006 10:20:00 10.5 1.3 14.5 8 10.4 1.3 14.1 7.6 9.1 1.3 12.6 6.5 309 6 307 165 5.6 0 5.7 5.5 10/23/2006 10:30:00 12.3 1.7 16.4 8 12.1 1.7 16.1 7.6 10.2 1.4 14.9 6.5 308 7 307 165 5.6 0 5.7 5.5 10/23/2006 10:40:00 11.6 1.1 14.9 8.4 11.5 1 14.9 8.4 10.1 1.3 13.3 7.2 309 6 313 165 5.4 0 5.7 5.2 10/23/2006 10:50:00 10.5 1.5 14.1 6.8 10.4 1.4 14.1 6.8 9.4 1.7 13.7 5.7 308 8 304 165 5.4 0 5.7 5.2 10/23/2006 11:00:00 10.8 1.6 15.3 6.5 10.7 1.6 15.3 6.5 9 1.5 15.3 5.7 305 9 310 165 5.6 0.1 5.7 5.2 10/23/2006 11:10:00 12.6 1.3 15.3 7.6 12.5 1.3 15.6 8 10.7 1.7 16.1 6.8 304 9 318 165 5.7 0 6 5.5 10/23/2006 11:20:00 13.9 1.5 19.1 10.3 13.7 1.5 19.1 10.7 11.4 1.8 16.8 7.6 301 9 305 165 5.8 0 6 5.7 10/23/2006 11:30:00 14.6 1.2 17.9 11.5 14.5 1.3 17.9 11.5 11.6 1.7 17.2 8 302 7 289 165 6 0 6.2 5.7 10/23/2006 11:40:00 14 1.8 18.7 9.5 14 1.9 19.1 9.1 11.3 1.9 16.8 7.2 300 8 292 165 6.1 0 6.2 6 10/23/2006 11:50:00 14.8 1.7 19.1 9.5 14.8 1.7 19.5 9.5 12.2 2.3 17.9 8 293 6 286 165 6 0 6.2 5.7 10/23/2006 12:00:00 11.6 1.7 14.9 8.4 11.6 1.7 14.9 8 9.5 1.7 14.1 5.7 298 8 307 165 6.1 0 6.2 5.7 10/23/2006 12:10:00 12.1 1.5 16.1 8.8 12.1 1.5 15.6 8.4 9.9 1.5 14.1 6.1 303 7 306 165 6.2 0 6.5 5.7 10/23/2006 12:20:00 11 1.1 14.1 7.6 10.9 1 14.1 7.6 10 1.3 13 6.8 313 9 296 165 6.5 0.2 7 5.7 10/23/2006 12:30:00 9 1.7 12.2 4.2 8.9 1.5 11.8 4.6 8.4 1.8 11.8 3.8 314 12 322 165 6.9 0.1 7.3 6.7 10/23/2006 12:40:00 6.6 1.5 11.1 3.8 6.6 1.4 11.1 3.8 6.1 1.3 10.7 3 311 12 316 165 7.6 0.2 8.3 7 10/23/2006 12:50:00 9.5 1.5 14.1 6.1 9.4 1.5 14.1 5.3 8.5 1.5 13 4.2 307 11 307 165 6.9 0.3 8 6.2 10/23/2006 13:00:00 12 2 16.8 6.8 11.9 2 16.8 6.5 10 1.7 14.5 5.7 305 10 295 165 6.4 0.2 7 6 10/23/2006 13:10:00 11.8 1.6 18.3 7.6 11.8 1.6 17.6 7.6 10.2 1.7 14.5 6.1 300 12 304 165 6.1 0 6.2 6 10/23/2006 13:20:00 14.1 1.7 19.1 10.3 14 1.7 19.1 9.9 11.7 1.9 17.2 6.8 299 9 293 165 6.2 0.1 6.5 5.7 10/23/2006 13:30:00 15.8 1.7 19.9 10.7 15.7 1.7 19.9 10.7 13.5 1.9 19.9 8.8 306 8 309 165 6.2 0 6.2 5.7 10/23/2006 13:40:00 17 1.5 20.6 13.3 16.9 1.5 20.6 12.6 13.8 2 19.9 10.3 303 7 301 165 6.2 0 6.7 6 10/23/2006 13:50:00 15.6 1.9 19.9 10.7 15.4 1.9 19.5 10.3 13.5 2.5 19.5 8.8 307 7 306 165 6.2 0 6.2 6 10/23/2006 14:00:00 14.7 2 18.7 9.1 14.6 2 19.1 8.4 12.2 2.3 18.3 6.5 305 8 305 165 6.2 0 6.2 6 10/23/2006 14:10:00 12.7 1.6 16.8 7.6 12.6 1.6 16.4 7.6 11.2 1.7 16.1 6.1 309 8 319 165 6 0.2 6.2 5.5 10/23/2006 14:20:00 13.4 2.6 19.9 8.4 13.3 2.5 20.6 8.4 11.6 2.5 21.4 6.8 306 10 321 165 6.1 0 6.2 5.7 10/23/2006 14:30:00 16.8 2.4 22.6 11.5 16.6 2.5 22.1 11.5 13.6 2.3 21.8 8.4 304 7 302 165 6 0 6.5 5.7 10/23/2006 14:40:00 16 2.3 21.8 11.1 15.9 2.3 21.4 11.1 13.3 2.2 18.7 8.4 304 9 293 165 6 0 6.2 5.5 10/23/2006 14:50:00 15.6 1.7 19.5 11.1 15.5 1.7 19.5 10.7 12.7 1.9 17.9 8 303 8 300 165 6.2 0.1 6.5 5.5 10/23/2006 15:00:00 14.7 1.9 18.7 9.5 14.7 2 18.7 9.5 12.3 1.8 17.2 7.2 305 10 290 165 6.4 0.1 6.7 6.2 10/23/2006 15:10:00 15 2 20.2 10.3 15 2 20.2 10.3 12.6 1.9 19.9 8.4 303 8 300 165 6.4 0.1 6.7 6.2 10/23/2006 15:20:00 17.7 2.3 23.3 13 17.6 2.3 22.9 13 14.2 2.4 22.6 9.5 303 7 305 165 6.1 0.1 6.2 5.5 10/23/2006 15:30:00 17.8 1.7 22.1 12.6 17.7 1.7 22.1 12.6 14.2 2 21 9.5 303 7 300 165 5.9 0.1 6.2 5.5 10/23/2006 15:40:00 18.5 2.2 23.7 12.6 18.5 2.2 23.3 12.2 14.9 2.4 21.8 8.4 303 7 297 165 5.9 0.1 6.2 5.5 10/23/2006 15:50:00 17.9 2 22.9 13.7 17.8 1.9 22.6 13.3 14.8 2.4 21 9.1 306 6 305 165 5.9 0 6.2 5.7 10/23/2006 16:00:00 15.9 1.7 20.6 12.6 15.9 1.7 19.9 11.8 13.1 2.1 19.1 8.4 306 6 316 165 6 0 6.2 5.2 10/23/2006 16:10:00 16 1.9 21.4 11.1 15.9 2 21.4 10.7 13.1 2.7 20.6 7.6 305 7 307 165 5.9 0.1 6.2 5.2 10/23/2006 16:20:00 16.8 2 22.9 12.6 16.6 2 22.6 12.2 15.2 2.1 22.1 9.1 311 7 291 165 5.6 0 5.7 5.2 10/23/2006 16:30:00 15.9 2.2 21 10.7 15.8 2.1 20.6 10.7 14 2.4 19.5 8.8 309 7 303 165 5.3 0 5.7 5 10/23/2006 16:40:00 12.4 2.3 19.1 7.6 12.4 2.3 19.5 7.6 10.7 2.4 19.1 6.8 306 9 295 165 5.1 0.2 5.5 4.8 10/23/2006 16:50:00 13.8 2.1 20.2 9.9 13.7 2.1 19.9 9.1 11.6 2 17.2 7.2 303 9 301 165 5.2 0.1 5.7 4.8 10/23/2006 17:00:00 11.7 1.8 16.1 7.6 11.8 1.9 16.1 7.6 10.4 2.2 16.1 5.7 290 9 287 165 5.1 0 5.2 4.5 10/23/2006 17:10:00 12.6 2 17.9 7.6 12.6 2 18.3 8 11.3 2.5 18.3 6.8 287 8 282 165 5.1 0 5.2 4.8 10/23/2006 17:20:00 12.6 1.8 16.8 9.1 12.7 1.9 16.8 9.1 11.6 2.4 16.8 7.2 286 7 280 165 4.9 0 5.2 4.8 10/23/2006 17:30:00 10.6 1.9 15.6 6.1 10.6 1.9 15.3 6.5 9.1 2.1 14.9 4.9 294 10 308 165 4.9 0.1 5.2 4.5 10/23/2006 17:40:00 11 2.2 17.6 6.1 11 2.2 17.2 6.5 9.5 2.3 15.6 4.6 304 10 312 165 4.9 0 5 4.5 10/23/2006 17:50:00 11 1.5 16.1 6.8 10.9 1.5 15.6 7.2 9.4 1.6 14.1 5.7 303 9 304 165 4.8 0 5 4.5 10/23/2006 18:00:00 8.9 1.8 13.3 5.7 8.9 1.8 13.3 5.3 7.9 1.9 13.3 4.2 291 10 276 165 4.6 0.1 5 4 10/23/2006 18:10:00 8.8 1.5 12.6 5.3 8.8 1.5 12.6 4.9 7.7 1.3 11.1 4.2 290 9 299 165 4.6 0.1 4.8 4 10/23/2006 18:20:00 6.3 1.2 9.1 2.6 6.6 1.2 9.5 3 6.3 1.2 9.5 3 281 9 286 165 4.4 0 4.8 4.3 10/23/2006 18:30:00 6.3 1 10.3 3.8 6.6 1 9.9 4.6 6.4 1.1 9.9 3.4 279 9 291 165 4.3 0 4.8 4.3 10/23/2006 18:40:00 7.1 1.3 11.1 3.8 7.8 1.4 11.8 4.9 7.6 1.2 11.5 4.9 270 12 282 165 4.4 0 4.8 4 10/23/2006 18:50:00 6.3 1.3 9.9 3.8 6.6 1.2 9.9 3.8 6.3 1.2 9.9 3.8 277 12 281 165 4.5 0 4.8 4.3 10/23/2006 19:00:00 6.1 1.4 11.5 3.4 6.8 1.1 11.1 4.2 6.3 1 10.7 4.2 272 13 283 165 4.2 0.2 4.8 3.5 10/23/2006 19:10:00 5.5 1.5 9.9 2.3 6.4 1.4 10.7 3.4 6.2 1.4 10.7 3.8 264 9 284 165 4.1 0.1 4.5 3.5 10/23/2006 19:20:00 7.3 1.7 12.2 3.8 8.1 1.5 12.2 4.9 7.9 1.5 12.6 5.3 271 12 284 165 4.1 0 4.5 3.8 10/23/2006 19:30:00 9.5 1.3 12.6 6.5 9.6 1.3 13 6.5 9 1.5 12.2 4.9 284 7 305 165 4.1 0 4.5 3.8 10/23/2006 19:40:00 8.6 1 11.5 6.1 8.8 1 11.5 6.5 8.1 1.2 11.8 4.9 284 7 281 165 4.1 0.1 4.3 3.5 10/23/2006 19:50:00 8.7 1.2 12.6 5.7 8.8 1.2 12.6 6.1 7.8 1.2 10.7 4.6 288 8 297 165 4.2 0 4.5 3.8 10/23/2006 20:00:00 7.8 0.9 10.3 5.7 7.7 1 10.3 4.9 7.3 1.1 10.7 4.6 286 8 298 165 4.3 0 4.5 3.8 10/23/2006 20:10:00 6 1.1 8.8 4.2 6 1.1 8.8 4.2 5.5 1.3 9.1 2.6 288 6 281 165 4.1 0.1 4.5 3.5 10/23/2006 20:20:00 5.5 1.1 8.4 2.6 5.6 1.1 8.4 3.4 5.1 1.1 7.6 2.6 283 10 290 165 4.1 0.1 4.3 3.5 10/23/2006 20:30:00 6.4 0.9 8.4 3.8 6.9 0.7 8.8 4.9 6.7 0.8 8.4 4.6 273 9 273 165 4.1 0 4.5 3.5 10/23/2006 20:40:00 5.3 0.8 7.6 3.4 5.5 0.8 7.2 3 5.3 0.9 7.6 3.4 279 7 280 165 4 0 4.3 3.5 10/23/2006 20:50:00 5.1 0.8 7.6 2.6 5.7 0.8 8 3.8 5.2 0.8 6.8 3 273 10 274 165 3.9 0 4.3 3.8 10/23/2006 21:00:00 6.4 1 8.8 3.4 6.6 0.9 8.8 4.6 6.3 0.9 8.4 3.8 280 7 289 165 3.9 0 4.5 3.8 10/23/2006 21:10:00 6.5 0.7 8 4.2 6.5 0.8 8.4 4.6 6.2 0.8 8 4.2 281 5 274 165 4 0 4.3 3.8 10/23/2006 21:20:00 6.8 0.8 9.5 4.6 7 0.8 9.5 4.9 6.6 0.9 9.1 3.8 282 7 276 165 4 0 4.3 3.8 10/23/2006 21:30:00 5.8 0.6 7.2 4.2 5.9 0.6 7.6 4.6 5.4 0.7 6.8 3.4 285 7 287 165 3.8 0.2 4.3 3.5 10/23/2006 21:40:00 5.6 0.8 7.6 3.4 5.8 0.8 7.6 3.4 5.5 0.8 7.6 3.4 282 7 279 165 3.6 0 3.8 3.5 10/23/2006 21:50:00 5.1 0.9 6.8 2.6 5.7 0.7 7.6 4.2 5.3 0.8 7.2 3 271 9 282 165 3.6 0.1 4 3.5 10/23/2006 22:00:00 5.4 0.7 6.8 3.4 6 0.6 7.2 4.6 5.6 0.5 6.8 4.2 273 6 279 165 3.6 0 3.8 3.5 10/23/2006 22:10:00 5.2 0.9 7.6 3 6.1 0.7 8 4.6 5.7 0.7 7.2 3.4 263 8 245 165 3.8 0 4.3 3.5 10/23/2006 22:20:00 4 1.1 6.5 1.5 4.5 0.8 6.5 2.6 4.1 0.8 6.1 2.6 255 11 245 165 3.8 0 4.3 3.5 10/23/2006 22:30:00 3.4 0.7 5.3 2.3 3.4 0.7 5.7 2.3 3.5 0.7 5.7 2.3 207 20 241 165 3.6 0.1 4.3 3.5 10/23/2006 22:40:00 2.8 0.3 3.8 1.9 2.7 0.3 3.8 1.9 2.9 0.3 3.8 2.3 202 4 196 165 3.6 0 3.8 3.5 10/23/2006 22:50:00 2.6 0.3 3 1.9 2.6 0.3 3.4 1.9 2.8 0.3 3.4 2.3 201 5 196 165 3.8 0 4.3 3.5 10/23/2006 23:00:00 2.8 0.3 3.4 2.3 2.8 0.3 3.4 2.3 3.1 0.3 3.8 2.6 195 5 204 165 3.9 0 4.3 3.8 10/23/2006 23:10:00 3.4 0.4 4.2 2.6 3.4 0.4 4.6 2.3 3.7 0.4 4.6 3 197 6 202 165 3.7 0.2 4.3 3.5 10/23/2006 23:20:00 3.3 0.4 4.2 2.6 3.3 0.4 4.6 2.6 3.6 0.3 4.2 3 196 4 198 165 3.5 0 3.5 3.3 10/23/2006 23:30:00 4.4 0.4 5.3 3.4 4.3 0.3 4.9 3.4 4.5 0.4 5.3 3.4 183 8 177 165 3.4 0 3.8 3.3 10/23/2006 23:40:00 3.6 0.7 5.7 1.9 3.6 0.6 5.3 2.3 3.6 0.7 5.7 2.3 180 9 182 165 3.3 0 3.8 3 10/23/2006 23:50:00 3.4 0.7 5.3 1.9 3.3 0.7 5.3 1.9 3.4 0.7 4.9 1.9 164 18 175 165 3.2 0 3.5 2.8 10/24/2006 00:00:00 3.2 0.5 4.6 1.5 3.1 0.5 4.6 1.5 3.2 0.4 4.2 1.9 161 17 155 165 2.9 0.1 3.3 2.6 10/24/2006 00:10:00 4 0.6 5.3 2.6 3.9 0.5 5.3 2.6 4 0.6 5.7 2.3 189 8 194 165 3 0.1 3.5 2.6 10/24/2006 00:20:00 4.1 0.6 4.9 3 4 0.5 4.9 3 4.4 0.6 5.3 3 181 7 181 165 3.2 0 3.8 3 10/24/2006 00:30:00 6.2 1.1 8.4 3.4 6.2 1.1 8 3.4 6.3 1 8.4 3.8 187 10 194 165 3.1 0 3.5 2.8 10/24/2006 00:40:00 6.6 0.3 7.6 5.7 6.7 0.3 7.6 6.1 7.1 0.4 8 5.7 194 4 190 165 3.2 0 3.5 3 10/24/2006 00:50:00 5.8 0.7 7.6 4.9 5.9 0.7 7.2 4.9 6.2 0.8 8 5.3 190 3 196 165 3.2 0 3.5 3 10/24/2006 01:00:00 5.6 0.4 6.5 4.2 5.5 0.4 6.1 4.2 5.9 0.5 6.8 4.6 185 5 184 165 3.1 0 3.8 3 10/24/2006 01:10:00 3.9 0.5 5.3 2.6 3.8 0.5 5.3 2.6 4 0.5 5.7 2.6 175 12 189 165 3.4 0 3.5 3.3 10/24/2006 01:20:00 3.1 0.6 4.6 1.9 3 0.6 4.2 1.9 3.3 0.6 4.6 1.9 172 4 178 165 3.3 0 3.5 3.3 10/24/2006 01:30:00 3.1 0.7 4.6 1.9 3 0.7 4.6 1.5 3 0.7 4.2 1.9 160 5 156 165 3.5 0 3.8 3.3 10/24/2006 01:40:00 4.3 0.3 5.3 3.4 4.2 0.3 4.9 3.4 4.5 0.4 5.3 3.8 158 4 159 165 3.3 0 3.5 3.3 10/24/2006 01:50:00 4.4 0.6 6.1 3 4.3 0.6 5.7 2.6 4.5 0.6 6.1 3 156 6 151 165 3.3 0 3.5 3.3 10/24/2006 02:00:00 5.6 0.7 7.2 3.8 5.5 0.7 7.6 4.2 5.6 0.7 7.2 4.2 152 7 149 165 3.4 0 3.5 3.3 10/24/2006 02:10:00 5.4 0.5 6.8 4.2 5.4 0.5 6.8 4.2 5.5 0.5 7.2 4.6 153 6 149 165 3.4 0 3.5 3.3 10/24/2006 02:20:00 5.2 0.7 6.8 3 5.2 0.7 6.8 3.4 5.5 0.8 7.2 3.4 156 9 157 165 3.6 0 3.8 3.5 10/24/2006 02:30:00 5.7 0.7 7.6 3.8 5.7 0.7 7.2 4.2 5.9 0.6 7.6 4.6 163 7 158 165 3.6 0 3.8 3.3 10/24/2006 02:40:00 7.1 0.9 9.5 5.3 6.9 0.9 9.1 5.3 7.3 1 9.5 4.9 166 19 165 165 3.6 0 4 3.5 10/24/2006 02:50:00 8.9 0.4 10.3 8 8.6 0.4 9.5 7.6 9.2 0.4 10.3 8 164 6 171 165 3.9 0 4.3 3.5 10/24/2006 03:00:00 8.1 0.8 9.5 5.7 7.8 0.8 9.1 5.7 8.3 0.8 9.9 6.1 162 13 160 165 4 0 4.3 3.8 10/24/2006 03:10:00 6.8 0.5 8.8 5.3 6.7 0.5 8 4.9 7.2 0.6 8.4 5.7 158 5 158 165 4 0 4.3 3.8 10/24/2006 03:20:00 6.3 0.5 7.6 4.9 6.2 0.5 7.6 4.9 6.5 0.5 8 4.9 159 11 158 165 4.1 0 4.3 3.8 10/24/2006 03:30:00 7 0.5 8.4 5.7 6.8 0.5 8 5.3 7.3 0.5 8.4 5.7 162 12 165 165 4.2 0 4.5 4 10/24/2006 03:40:00 7.8 0.4 8.8 6.8 7.5 0.4 8.4 6.5 8.2 0.5 9.1 7.2 164 10 163 165 4.1 0.1 4.5 4 10/24/2006 03:50:00 6.4 0.3 7.2 5.7 6.2 0.3 6.8 5.7 6.8 0.3 7.6 6.1 163 4 167 165 4.1 0 4.3 3.8 10/24/2006 04:00:00 6.9 0.3 8 6.1 6.6 0.3 7.6 6.1 7.1 0.2 8 6.8 166 13 165 165 4.1 0 4.3 3.8 10/24/2006 04:10:00 7.1 0.7 8.8 5.3 6.9 0.6 8.8 5.3 7.2 0.8 9.1 5.7 179 8 186 165 4.1 0.1 4.8 3.8 10/24/2006 04:20:00 7 0.7 8.8 5.3 6.9 0.6 8.4 4.9 7.4 0.8 9.9 5.3 178 8 166 165 4.4 0 4.8 4.3 10/24/2006 04:30:00 6 0.6 7.6 4.6 5.8 0.5 7.2 4.6 6.3 0.6 8 4.9 183 7 187 165 4.3 0 4.5 4.3 10/24/2006 04:40:00 5.5 0.4 7.2 4.6 5.4 0.4 6.8 4.6 5.9 0.4 6.8 4.9 182 3 177 165 4.3 0 4.8 4.3 10/24/2006 04:50:00 5.5 0.3 6.8 4.9 5.3 0.3 6.5 4.6 5.8 0.3 6.5 4.9 185 5 181 165 4.3 0 4.5 4.3 10/24/2006 05:00:00 5.1 0.5 6.5 4.2 5 0.4 5.7 4.2 5.3 0.4 6.5 4.6 181 4 186 165 4.4 0 4.8 4.3 10/24/2006 05:10:00 6.1 1 9.1 3.8 6.1 1 8.8 3.8 6.3 1 9.1 3.8 194 6 188 165 4.5 0 4.8 4.5 10/24/2006 05:20:00 7.8 0.7 11.5 6.5 7.8 0.8 10.7 6.1 8 0.8 11.1 6.1 189 7 191 165 4.7 0 5 4.5 10/24/2006 05:30:00 7.3 0.7 9.5 5.3 7.1 0.7 9.1 5.3 7.5 0.8 9.5 5.7 185 7 185 165 4.6 0 5 4.5 10/24/2006 05:40:00 8.8 0.8 10.3 6.8 8.7 0.8 10.3 6.8 9 0.9 11.1 6.8 190 4 186 165 4.7 0 5 4.5 10/24/2006 05:50:00 8.9 0.7 10.3 7.2 8.6 0.6 9.9 7.2 9.1 0.7 10.7 7.2 177 5 174 165 4.9 0 5 4.8 10/24/2006 06:00:00 8.2 0.5 9.5 6.5 7.9 0.5 9.1 6.5 8.4 0.5 9.5 6.8 175 5 181 165 5.1 0 5.5 4.8 10/24/2006 06:10:00 8.9 0.8 11.1 6.8 8.6 0.8 10.3 6.8 9.1 0.8 10.7 7.2 169 6 171 165 5.2 0 5.5 5 10/24/2006 06:20:00 10.4 1 13 8.8 10.1 1 12.6 8.4 10.6 1.1 14.1 8.4 169 10 176 165 5.4 0 5.7 5.2 10/24/2006 06:30:00 13 1 15.6 9.9 12.6 1 15.3 9.5 13.2 1 16.1 10.7 168 8 176 165 5.4 0 5.7 5.2 10/24/2006 06:40:00 13.6 0.9 15.6 11.1 13.3 0.8 15.6 10.7 13.8 1 16.4 11.1 168 6 162 165 5.2 0.1 5.5 4.8 10/24/2006 06:50:00 14.2 1 16.4 11.1 13.9 1 16.4 10.7 14.4 1.2 17.2 11.8 169 12 165 165 4.9 0 5.2 4.8 10/24/2006 07:00:00 14.5 0.8 16.1 12.2 14.3 0.8 16.1 11.5 14.7 0.9 16.8 12.2 174 7 176 165 5 0 5.2 4.8 10/24/2006 07:10:00 14.2 1 16.8 11.1 14 1 16.4 11.1 14.4 1.1 16.8 11.5 170 14 157 165 4.9 0 5.2 4.8 10/24/2006 07:20:00 13.6 1 15.6 10.3 13.3 1 15.6 9.9 13.8 1 16.1 11.1 168 7 165 165 4.8 0 5 4.8 10/24/2006 07:30:00 15.3 1.3 18.3 12.6 14.9 1.3 17.9 12.2 15.3 1.4 18.3 11.8 169 12 171 165 4.8 0 5 4.8 10/24/2006 07:40:00 13.5 2.1 17.2 8.4 13.2 2.1 16.8 8.4 13.7 2.2 17.2 8.4 171 15 166 165 4.7 0.1 5 4.5 10/24/2006 07:50:00 10.4 1.6 14.5 6.5 10.3 1.5 14.5 6.5 10.6 1.5 14.1 6.1 185 10 175 165 4.6 0 4.8 4.5 10/24/2006 08:00:00 10.8 1.3 14.5 7.6 10.7 1.3 14.1 7.6 10.9 1.5 15.3 6.8 188 6 187 165 4.4 0 4.8 4.3 10/24/2006 08:10:00 9.3 1.1 12.2 6.8 9.1 1.1 11.8 6.8 9.3 1 11.8 7.6 185 7 180 165 4.3 0 4.8 4.3 10/24/2006 08:20:00 7.3 0.6 8.8 6.1 7.1 0.6 8.4 5.7 7.5 0.6 8.8 6.1 171 6 179 165 4.3 0 4.8 4.3 10/24/2006 08:30:00 6.5 0.4 7.6 5.7 6.3 0.4 7.2 5.3 6.8 0.4 7.6 5.7 168 4 168 165 4.4 0 4.5 4.3 10/24/2006 08:40:00 8.1 1.7 11.5 5.7 7.9 1.7 11.5 5.7 8.3 1.7 11.5 6.1 166 9 165 165 4.5 0.1 5 4.3 10/24/2006 08:50:00 10.3 0.8 12.2 8.4 10.3 0.7 12.2 8 10.3 0.8 12.2 7.6 161 11 165 165 4.9 0 5 4.8 10/24/2006 09:00:00 10.7 1 13 7.6 10.7 1 12.6 7.6 11 1 13 8.4 155 8 147 165 4.9 0 5.2 4.5 10/24/2006 09:10:00 10.8 1.1 13.7 8 10.7 1.1 13.7 8 10.9 1.1 13.7 7.2 162 15 162 165 4.7 0 5 4.5 10/24/2006 09:20:00 11.7 0.7 13.3 9.1 11.7 0.7 13.3 9.5 12 0.8 14.5 9.1 164 10 165 165 4.7 0 5 4.5 10/24/2006 09:30:00 11.9 0.8 13.7 9.1 11.6 0.7 13.3 9.5 11.9 0.8 14.1 9.1 165 10 165 165 4.7 0 5 4.5 10/24/2006 09:40:00 12.2 0.9 13.7 9.9 12 0.8 14.1 9.1 12.3 1 14.1 9.9 162 11 156 165 4.7 0.1 5 4.5 10/24/2006 09:50:00 11.5 1.2 13.7 8.4 11.4 1.1 13.3 8 11.8 1.2 14.1 8.4 163 11 165 165 4.6 0 5 4.5 10/24/2006 10:00:00 11.4 0.9 13.7 8.8 11.3 0.9 13.3 8.8 11.7 1 14.1 9.1 160 17 161 165 4.8 0 5 4.5 10/24/2006 10:10:00 10.4 1.2 13.7 7.2 10.2 1.2 13 6.8 10.6 1.3 13.3 8 157 6 157 165 4.9 0 5 4.8 10/24/2006 10:20:00 9.4 0.6 11.1 8 9.3 0.6 11.1 8 9.7 0.7 11.5 7.6 156 5 160 165 4.9 0 5 4.8 10/24/2006 10:30:00 9.2 1 11.8 6.8 9 0.9 11.8 7.2 9.2 0.9 11.8 7.2 158 7 165 165 4.8 0 5 4.5 10/24/2006 10:40:00 9.1 0.6 10.7 7.2 9 0.6 10.3 6.8 9.3 0.6 11.1 7.2 161 9 162 165 4.8 0 5 4.5 10/24/2006 10:50:00 9 0.6 10.7 7.2 8.8 0.5 10.3 7.2 9.2 0.6 10.7 7.6 166 11 165 165 4.8 0 5 4.8 10/24/2006 11:00:00 9.8 0.7 11.1 8 9.5 0.6 11.1 8 9.9 0.7 11.8 8 169 15 166 165 4.6 0 5 4.5 10/24/2006 11:10:00 10.3 0.8 11.8 8 10 0.8 11.8 8 10.5 0.9 12.6 8.4 172 5 179 165 4.3 0.1 4.8 4.3 10/24/2006 11:20:00 9.5 0.6 11.1 7.6 9.3 0.6 10.7 7.6 9.7 0.7 11.1 7.6 169 5 172 165 4.2 0 4.5 4.3 10/24/2006 11:30:00 8.6 0.7 10.3 6.8 8.4 0.7 9.9 6.5 8.7 0.8 10.3 6.5 169 11 165 165 4.3 0 4.5 4.3 10/24/2006 11:40:00 7.2 0.7 8.8 5.3 7 0.6 8.8 5.3 7.2 0.9 9.1 4.6 171 7 173 165 4.2 0 4.5 4.3 10/24/2006 11:50:00 6.4 0.6 7.6 4.9 6.2 0.6 7.2 4.6 6.5 0.7 8.4 4.9 173 5 172 165 4.1 0 4.5 3.8 10/24/2006 12:00:00 5.2 0.5 6.5 4.2 5 0.5 6.1 3.8 5.3 0.5 6.5 3.8 168 9 176 165 3.8 0 4 3.5 10/24/2006 12:10:00 4 0.4 4.9 3 3.9 0.4 4.9 2.6 4.2 0.4 5.3 3 161 5 155 165 3.8 0 4 3.5 10/24/2006 12:20:00 3.9 1 6.1 1.9 3.7 1 6.1 1.9 4 1 6.1 2.3 158 8 152 165 3.7 0.1 4.3 3.5 10/24/2006 12:30:00 4.3 1.3 6.8 1.5 4.2 1.3 6.8 1.5 4.2 1.2 6.5 1.9 128 17 128 165 3.8 0 4.3 3.5 10/24/2006 12:40:00 5.3 1.2 8 2.3 5.2 1.3 8.4 2.3 5.2 1.1 8 2.6 143 15 147 165 4 0 4.3 3.8 10/24/2006 12:50:00 3.9 0.7 6.5 2.3 3.9 0.7 6.5 1.9 3.8 0.6 5.3 2.3 119 13 114 165 4.1 0 4.5 3.8 10/24/2006 13:00:00 5.1 1.1 8.8 3 5.2 1.1 8.8 3 5 1 8.4 3.4 97 14 83 165 4.5 0.1 4.8 4.3 10/24/2006 13:10:00 7.3 1.2 9.9 4.9 7.4 1.2 10.3 4.9 7.2 1.4 10.7 4.2 96 11 82 165 4.9 0 5 4.5 10/24/2006 13:20:00 5.3 1.4 9.1 1.5 5.4 1.5 9.1 1.5 5.3 1.5 9.9 1.9 79 16 102 165 5.1 0 5.2 4.8 10/24/2006 13:30:00 3 0.8 4.2 0.4 2.8 0.8 4.2 0.4 3.3 0.8 4.9 0.7 30 18 19 165 4.5 0 4.8 4.3 10/24/2006 13:40:00 3.3 0.8 6.1 1.5 3 0.9 5.7 1.1 3.6 0.6 5.3 2.3 22 7 18 165 4.6 0 4.8 4.3 10/24/2006 13:50:00 2.4 0.5 3.8 1.5 2 0.8 3.8 0.4 2.7 0.5 4.2 1.5 338 17 342 165 4.7 0 5 4.5 10/24/2006 14:00:00 4.6 0.9 6.5 2.3 4.9 0.9 6.8 2.3 5.2 0.9 6.8 2.3 277 8 275 165 4.3 0.2 4.8 4 10/24/2006 14:10:00 5.3 0.7 7.2 3.4 5.3 0.7 7.2 3.8 5.4 0.7 8 3 280 5 282 165 4.1 0 4.5 4 10/24/2006 14:20:00 7.6 0.8 9.5 4.9 7.7 0.8 9.5 5.3 7 0.9 8.8 4.9 288 6 287 165 3.9 0 4.3 3.8 10/24/2006 14:30:00 8 0.7 9.5 6.1 8 0.7 9.9 6.1 6.8 1 9.9 4.6 293 5 292 165 3.8 0 4 3.8 10/24/2006 14:40:00 8.3 1.1 10.7 4.2 8.3 1.1 10.3 4.6 7 1.1 9.9 3.4 294 6 298 165 3.8 0 4 3.8 10/24/2006 14:50:00 9.9 1.5 12.2 5.3 9.9 1.5 12.2 5.3 7.7 1.4 11.5 4.2 296 5 294 165 3.9 0 4 3.8 10/24/2006 15:00:00 11.4 0.8 13.7 8 11.3 0.8 13.3 8 8.8 1 11.8 6.1 299 5 306 165 3.9 0 4 3.8 10/24/2006 15:10:00 9.9 1.6 13.3 5.7 9.8 1.5 13.3 6.1 8.2 1.1 12.2 5.3 311 13 292 165 4.1 0.1 4.5 3.8 10/24/2006 15:20:00 10.2 1.3 13.7 6.8 10 1.5 14.5 5.7 9.8 1.2 13.3 6.5 337 11 338 165 4.6 0 4.8 4.3 10/24/2006 15:30:00 9.7 1.3 13.3 6.1 9.6 1.3 13.7 6.1 9.2 1.2 11.8 6.1 336 9 340 165 4.6 0 4.8 4.3 10/24/2006 15:40:00 10.6 1.4 14.1 7.2 10.6 1.4 13.7 7.2 10.2 1.5 14.5 5.7 336 7 342 165 4.3 0.1 4.5 4.3 10/24/2006 15:50:00 10.5 1.3 13.7 5.7 10.4 1.5 13.7 6.1 10.3 1.4 13.7 6.1 336 8 321 165 4 0 4.3 3.8 10/24/2006 16:00:00 10.8 1.3 14.5 7.2 10.6 1.5 14.5 6.8 10.4 1.3 13.3 6.5 339 8 337 165 3.6 0.1 3.8 3.5 10/24/2006 16:10:00 8.9 1.9 13.3 4.6 8.7 1.8 12.6 4.9 8 2.3 14.1 4.2 324 23 1 165 3.6 0 3.8 3.5 10/24/2006 16:20:00 10.8 1.4 14.1 7.2 10.7 1.4 14.1 7.2 9 1.4 12.6 5.7 305 6 306 165 3.4 0 3.8 3.3 10/24/2006 16:30:00 12.2 1.3 15.6 9.5 12.2 1.3 15.6 9.5 10.6 1.3 14.1 7.2 307 5 308 165 3.1 0.1 3.5 2.8 10/24/2006 16:40:00 12.7 1 15.3 9.9 12.6 1 14.9 9.5 11.9 1 14.1 8.8 312 6 306 165 2.8 0 3 2.6 10/24/2006 16:50:00 14.6 1.5 18.3 9.9 14.6 1.5 18.3 9.9 13.8 1.5 17.9 9.9 312 6 313 165 3 0 3.3 2.8 10/24/2006 17:00:00 12.8 1.5 16.4 8.8 12.8 1.5 16.4 9.1 11.8 1.3 15.3 8 311 6 312 165 3 0 3.3 2.8 10/24/2006 17:10:00 13.7 1.6 17.6 9.9 13.6 1.6 17.6 9.1 11.5 1.7 17.2 8 301 9 287 165 3.2 0 3.5 2.8 10/24/2006 17:20:00 15.1 1.9 21 11.1 15.1 1.9 20.2 11.1 13.4 2.3 19.5 8.8 304 9 277 165 3.2 0 3.5 3 10/24/2006 17:30:00 16.9 2 21 12.6 16.8 2.1 21 12.2 14.7 2.5 21.8 9.9 305 9 301 165 3.1 0.1 3.5 2.8 10/24/2006 17:40:00 17.7 1.7 21.8 13.3 17.7 1.7 21.8 13.3 16.6 2.1 21.4 9.9 309 5 305 165 2.8 0 3 2.6 10/24/2006 17:50:00 19.5 1.4 22.6 14.5 19.4 1.5 22.1 14.5 18.5 1.8 22.9 12.6 311 6 307 165 2.6 0 2.8 2.6 10/24/2006 18:00:00 19.5 1.9 26.3 14.9 19.5 2 26 14.9 17.8 2.1 23.3 12.6 308 6 302 165 2.6 0 2.8 2.6 10/24/2006 18:10:00 18 1.7 24 13.7 18 1.8 24 13.7 14.8 1.9 21 10.7 301 8 295 165 2.6 0 2.8 2.6 10/24/2006 18:20:00 18.9 2.6 26.8 13.3 18.8 2.7 27.1 13 16.3 2.7 23.7 9.5 303 8 302 165 2.5 0 2.8 2.3 10/24/2006 18:30:00 22.1 2.4 27.9 15.6 22 2.4 27.9 14.9 18.6 2.4 27.5 11.8 301 7 304 165 2.6 0 2.8 2.6 10/24/2006 18:40:00 22.9 2.4 29.8 15.6 22.9 2.5 30.2 15.3 19.6 2.7 26.3 13 299 7 297 165 2.6 0.1 2.8 2.3 10/24/2006 18:50:00 22.7 2 27.5 17.2 22.7 2.1 27.9 17.2 19.8 2.3 25.6 13.7 300 7 307 165 2.4 0 2.8 2.3 10/24/2006 19:00:00 21.9 2 29.1 16.8 21.8 2.1 29.4 16.1 20.1 2.6 30.6 14.1 304 8 320 165 2.1 0 2.6 2.1 10/24/2006 19:10:00 22.4 2 27.1 16.8 22.3 2.1 27.1 16.8 20.9 2.2 27.5 14.5 304 7 308 165 2.2 0 2.3 2.1 10/24/2006 19:20:00 22.5 2.2 30.6 17.6 22.4 2.3 30.2 17.2 21.5 2.6 29.8 14.5 307 7 309 165 2.1 0 2.3 1.8 10/24/2006 19:30:00 23.3 2.4 29.1 17.6 23.3 2.5 29.4 17.2 21.1 2.6 27.5 13.7 302 8 298 165 2.2 0 2.6 1.8 10/24/2006 19:40:00 24.2 2.6 30.2 17.6 24.2 2.6 30.2 17.9 23.1 2.9 32.4 16.8 307 7 310 165 2.2 0 2.3 2.1 10/24/2006 19:50:00 25.4 2.2 31.3 19.9 25.3 2.3 30.6 19.5 24.6 2.6 30.6 17.2 308 7 304 165 2.1 0 2.3 1.8 10/24/2006 20:00:00 25.3 2.2 30.9 19.1 25.2 2.3 31.3 18.3 24.4 2.5 31.8 18.7 310 6 305 165 2 0.1 2.3 1.8 10/24/2006 20:10:00 24.2 2 29.4 19.5 24.1 2.1 29.4 19.5 23.3 2.5 29.4 14.9 310 5 294 165 1.9 0 2.3 1.8 10/24/2006 20:20:00 22.5 1.8 27.9 17.6 22.4 1.9 27.9 17.6 21.4 2.1 28.3 15.3 310 7 303 165 1.8 0 2.3 1.6 10/24/2006 20:30:00 21.4 1.7 26.8 16.1 21.3 1.7 26.3 16.4 20.4 2 24.4 15.3 311 6 307 165 1.6 0 1.8 1.4 10/24/2006 20:40:00 22.6 1.7 26.3 17.6 22.5 1.7 26.3 17.6 20.6 1.8 25.2 15.3 310 4 297 165 1.5 0 1.6 1.4 10/24/2006 20:50:00 19.9 2 25.6 14.5 19.8 2 26 14.5 17.9 2.1 23.7 12.6 312 0 312 165 1.5 0 1.6 1.4 10/24/2006 21:00:00 18.2 1.4 21.8 14.1 18.2 1.3 21.4 14.5 17.2 1.6 21 13 312 0 311 165 1.4 0 1.6 1.4 10/24/2006 21:10:00 19 1.5 21.8 14.5 18.9 1.5 21.8 14.5 18 1.7 21.4 12.2 312 0 312 165 1.4 0 1.6 1.4 10/24/2006 21:20:00 19.2 1.9 23.3 14.1 19.1 1.8 22.9 14.5 17.9 1.8 22.6 13.3 312 0 312 165 1.3 0 1.4 1.4 10/24/2006 21:30:00 20.6 1.6 24.8 15.3 20.6 1.7 25.2 15.3 17.9 2.1 24 12.2 312 0 312 165 1.4 0 1.6 1.4 10/24/2006 21:40:00 19.2 2.1 25.2 15.3 19.2 2.1 24.4 14.9 16.8 2.4 22.1 11.5 312 0 312 165 1.4 0 1.6 1.4 10/24/2006 21:50:00 16.6 1.5 21.4 13.3 16.7 1.5 21.8 13.3 15.4 1.4 19.5 10.3 312 0 312 165 1.4 0 1.6 1.4 10/24/2006 22:00:00 16.9 1.6 21.8 13.3 17 1.6 22.1 13.3 15.3 2.1 22.1 9.9 312 0 312 165 1.4 0 1.6 1.4 10/24/2006 22:10:00 16.6 1.2 20.6 13 16.7 1.3 20.6 13 15.9 1.3 19.9 12.6 312 0 312 165 1.4 0 1.6 1.4 10/24/2006 22:20:00 16.4 1.1 19.5 13.3 16.5 1.1 19.9 13.7 15.5 1.4 18.7 11.5 312 0 312 165 1.4 0 1.6 1.4 10/24/2006 22:30:00 16.8 1.2 20.6 13.7 17 1.2 20.6 13.7 16.5 1.3 19.5 11.8 312 0 312 165 1.4 0 1.6 1.4 10/24/2006 22:40:00 16.9 1.6 21.4 11.8 17.1 1.6 21.4 11.8 16.5 1.5 21 11.5 312 0 312 165 1.4 0 1.6 1.4 10/24/2006 22:50:00 17.3 1.4 21.4 13.3 17.5 1.5 21.4 13.7 16.5 1.6 20.2 12.2 312 0 312 165 1.4 0 1.6 1.4 10/24/2006 23:00:00 17.6 1.3 21 14.1 17.9 1.3 21.4 14.5 16.7 1.4 20.2 12.2 312 0 312 165 1.4 0 1.6 1.4 10/24/2006 23:10:00 16.9 1.2 20.2 14.1 17.1 1.2 20.2 14.5 16.3 1.2 19.1 13 312 0 312 165 1.4 0 1.6 1.4 10/24/2006 23:20:00 15.9 1.2 19.9 12.6 16.1 1.2 20.2 13 15.1 1.3 19.1 11.1 312 0 312 165 1.4 0 1.6 1.4 10/24/2006 23:30:00 14.7 1.1 18.3 11.5 14.9 1.1 19.1 11.8 14.1 1.1 17.9 11.5 312 0 312 165 1.4 0 1.8 1.4 10/24/2006 23:40:00 14.3 0.9 16.4 11.8 14.5 0.9 16.8 12.2 13.6 0.9 15.6 11.1 312 0 312 165 1.4 0 1.6 1.4 10/24/2006 23:50:00 14.2 0.8 16.8 11.8 14.4 0.9 17.2 12.2 13.5 0.9 15.3 9.1 312 0 312 165 1.4 0 1.6 1.4 10/25/2006 00:00:00 13.6 1 16.8 10.3 13.8 1 16.8 10.7 12.9 1.1 16.1 9.1 312 0 312 165 1.4 0 1.6 1.4 10/25/2006 00:10:00 14.6 0.7 16.4 12.2 14.8 0.7 16.8 12.2 13.7 0.8 15.6 9.9 312 0 312 165 1.4 0 1.6 1.4 10/25/2006 00:20:00 15.3 0.7 17.9 13 15.6 0.8 17.9 13.7 14.1 1 16.4 10.3 312 0 312 165 1.4 0 1.6 1.4 10/25/2006 00:30:00 14.4 1.1 17.6 11.1 14.5 1.2 17.9 11.1 13.1 1.5 16.4 8 312 0 312 165 1.4 0 1.6 1.4 10/25/2006 00:40:00 14.8 0.8 17.2 12.6 15 0.9 17.2 12.6 12.8 1.2 15.3 8.8 312 0 311 165 1.4 0 1.6 1.4 10/25/2006 00:50:00 13.6 1 16.4 11.1 13.7 1 16.8 11.5 11.9 1.3 14.5 7.2 312 0 312 165 1.4 0 1.6 1.4 10/25/2006 01:00:00 13.2 1.2 17.2 10.3 13.3 1.1 17.2 10.3 11.7 1.4 14.9 7.6 312 0 312 165 1.4 0 1.6 1.4 10/25/2006 01:10:00 11.5 1.1 13.7 8.4 11.5 1.1 13.7 8.8 10.6 1.2 13.3 6.8 312 0 311 165 1.4 0 1.6 1.4 10/25/2006 01:20:00 10.9 1.1 13.3 8.4 11 1.1 13.3 8.4 10.2 1.2 13 6.1 312 0 312 165 1.4 0 1.6 1.4 10/25/2006 01:30:00 10.7 1 13.3 8 10.7 1 13.3 7.6 9.8 1.1 12.6 6.8 312 0 311 165 1.5 0 1.8 1.4 10/25/2006 01:40:00 9.4 0.7 11.1 7.6 9.3 0.7 11.1 7.6 8.3 1 10.7 4.9 312 0 311 165 1.5 0 1.6 1.4 10/25/2006 01:50:00 8.8 0.8 11.8 6.8 8.7 0.8 11.8 6.5 7 1 10.3 4.6 312 0 312 165 1.5 0 1.6 1.4 10/25/2006 02:00:00 9.2 0.8 11.5 7.2 9.2 0.8 11.1 7.2 7.1 1 9.5 4.6 312 0 312 165 1.5 0 1.8 1.4 10/25/2006 02:10:00 9.1 1 12.2 6.5 9.1 1 12.2 6.5 6.6 1 9.5 4.2 312 0 312 165 1.5 0 1.6 1.4 10/25/2006 02:20:00 10 1 12.2 7.2 10 1 12.6 7.6 8.2 1.2 11.1 5.7 312 0 312 165 1.5 0 1.6 1.4 10/25/2006 02:30:00 8.7 1 11.1 6.5 8.7 1 11.5 6.5 6.7 1 9.1 4.9 312 0 312 165 1.5 0 1.8 1.4 10/25/2006 02:40:00 8.4 0.8 10.3 5.7 8.4 0.9 10.3 5.3 6.2 1.1 8.8 4.2 312 0 311 165 1.5 0 1.6 1.4 10/25/2006 02:50:00 8.6 1 11.1 6.5 8.6 1 11.1 6.5 6.4 1.2 9.9 4.2 312 0 312 165 1.5 0 1.8 1.4 10/25/2006 03:00:00 8.1 0.8 9.9 6.1 8.2 0.9 10.3 6.1 6.3 1.2 9.5 3.4 312 0 312 165 1.5 0 1.8 1.4 10/25/2006 03:10:00 8.1 1 11.1 4.2 8.1 1 11.5 3.8 6.5 1.1 9.9 4.2 312 0 311 165 1.5 0 1.6 1.4 10/25/2006 03:20:00 10 1.1 12.6 6.8 10 1.2 12.6 6.8 8.1 1.5 11.5 4.6 312 0 312 165 1.5 0 1.8 1.4 10/25/2006 03:30:00 9.7 1 13 7.2 9.7 1 13 6.8 8.1 1.3 13 4.9 312 0 311 165 1.4 0 1.6 1.4 10/25/2006 03:40:00 11.1 1.2 14.5 7.6 11.1 1.3 14.1 7.6 8.7 1.3 12.6 6.1 312 0 311 165 1.4 0 1.6 1.4 10/25/2006 03:50:00 11.2 1.5 15.3 8 11.1 1.5 15.3 8 9.1 1.7 14.5 5.3 312 0 312 165 1.4 0 1.6 1.4 10/25/2006 04:00:00 10.4 1.7 14.1 6.5 10.3 1.7 14.1 6.1 8.7 1.7 13 5.3 312 0 312 165 1.3 0 1.6 1.1 10/25/2006 04:10:00 10.5 1.1 13 6.5 10.4 1.1 13 6.5 9.5 1.3 12.6 6.1 312 0 312 165 1.2 0 1.6 0.9 10/25/2006 04:20:00 11 1.2 14.5 8 10.8 1.2 13.7 7.6 9.6 1.6 15.3 6.1 312 0 312 165 1.2 0 1.4 0.9 10/25/2006 04:30:00 11.9 1.7 16.1 7.6 11.7 1.7 16.1 7.6 10.5 1.7 14.5 6.5 312 0 312 165 1.1 0 1.4 0.9 10/25/2006 04:40:00 12.1 1.7 16.1 8.4 11.9 1.7 15.6 8 10.8 1.6 14.9 7.2 312 0 312 165 0.9 0 1.4 0.9 10/25/2006 04:50:00 10.9 1.2 14.1 7.6 10.7 1.3 14.1 7.2 9.8 1.3 14.1 6.5 312 0 312 165 0.8 0 0.9 0.7 10/25/2006 05:00:00 12 1.7 16.1 8 11.8 1.7 15.6 7.6 10.2 1.6 14.9 6.5 312 0 312 165 0.8 0 0.9 0.7 10/25/2006 05:10:00 10.2 1.3 14.1 7.6 10 1.2 13.7 7.2 9.2 1.5 13.7 5.7 312 0 312 165 0.7 0 0.9 0.4 10/25/2006 05:20:00 10.3 1.1 13 6.8 10.1 1.2 13 6.8 8.7 1.5 12.6 5.3 312 0 312 165 0.5 0 0.9 0.4 10/25/2006 05:30:00 11.5 1.3 15.3 8 11.4 1.4 15.3 7.6 9.6 1.5 14.1 6.5 312 0 312 165 0.4 0 0.7 0.2 10/25/2006 05:40:00 12 1.5 16.1 8 11.8 1.5 15.3 8 10.1 1.5 15.3 6.8 312 0 312 165 0.4 0 0.7 0.2 10/25/2006 05:50:00 12.2 1.3 15.3 9.1 12.1 1.3 15.6 9.1 10.3 1.7 15.3 7.6 312 0 312 165 0.3 0 0.7 0.2 10/25/2006 06:00:00 12.6 1.7 16.4 8.8 12.5 1.7 17.2 8.4 10.8 2 16.1 7.2 312 0 312 165 0.3 0 0.7 0.2 10/25/2006 06:10:00 13.5 1.7 17.2 9.9 13.3 1.7 17.2 9.5 11.5 1.5 15.6 7.6 312 0 311 165 0.2 0 0.7 0.2 10/25/2006 06:20:00 13.4 1.3 16.8 9.9 13.3 1.4 17.2 9.5 11.4 1.6 16.1 8 312 0 311 165 0.2 0 0.7 0.2 10/25/2006 06:30:00 15.3 2.1 20.2 10.7 15.2 2.1 19.9 10.7 13.5 2.1 19.1 8.4 312 0 312 165 0.2 0 0.4 0.2 10/25/2006 06:40:00 14.8 1.5 17.9 10.7 14.7 1.5 17.9 10.7 12.7 1.4 17.2 8.4 312 0 312 165 0.2 0 0.4 0.2 10/25/2006 06:50:00 14.1 1.4 17.6 11.5 14 1.5 17.2 10.7 12.4 1.6 16.4 8.4 312 0 312 165 0.2 0 0.4 0.2 10/25/2006 07:00:00 14.3 1.2 16.8 10.7 14.2 1.2 17.2 10.3 12.4 1.5 16.1 8.8 312 0 312 165 0.2 0 0.7 0.2 10/25/2006 07:10:00 13.8 1.7 17.2 8.8 13.7 1.7 17.2 8.8 11.2 1.9 16.1 7.2 312 0 312 165 0.2 0 0.7 0.2 10/25/2006 07:20:00 14.1 1.3 17.2 9.9 13.9 1.4 17.2 10.3 11.6 1.5 16.4 8 312 0 312 165 0.2 0 0.7 0.2 10/25/2006 07:30:00 13.8 1.3 17.9 10.7 13.6 1.4 17.6 9.9 11.5 1.4 14.9 7.6 312 0 312 165 0.2 0 0.7 0.2 10/25/2006 07:40:00 12.3 1.5 16.8 9.1 12.1 1.6 16.4 9.1 10.2 1.6 15.3 6.8 312 0 312 165 0.2 0 0.4 0.2 10/25/2006 07:50:00 12.9 1.3 17.6 9.9 12.8 1.4 18.3 9.9 10.6 1.6 15.6 7.2 312 0 312 165 0.2 0 0.4 0.2 10/25/2006 08:00:00 13.7 1.7 19.5 8.8 13.6 1.7 19.1 8.4 11.3 1.8 17.2 6.8 312 0 312 165 0.2 0 0.7 -0.1 10/25/2006 08:10:00 14.5 1.5 18.3 10.7 14.3 1.5 18.7 11.1 12 1.7 16.8 7.6 312 0 312 165 0.5 0 0.7 0.2 10/25/2006 08:20:00 14.6 1.3 17.9 11.1 14.5 1.3 17.6 11.1 12 1.5 18.3 8.8 312 0 312 165 0.5 0 0.7 0.4 10/25/2006 08:30:00 13.9 1.2 17.2 10.3 13.8 1.2 17.2 9.9 12 1.8 17.2 7.6 312 0 312 165 0.5 0 0.9 0.4 10/25/2006 08:40:00 13.8 1.2 17.9 11.1 13.6 1.2 17.6 10.7 12 1.7 17.6 8.8 312 0 312 165 0.6 0 0.9 0.4 10/25/2006 08:50:00 14.3 1.3 18.3 10.7 14.1 1.3 18.3 10.7 12.5 1.5 17.2 8.4 312 0 312 165 0.7 0 0.9 0.7 10/25/2006 09:00:00 13 1.3 16.1 9.5 12.9 1.3 16.1 9.5 10.6 1.5 14.1 7.2 312 0 312 165 0.8 0 1.1 0.7 10/25/2006 09:10:00 13.7 1.3 17.6 9.9 13.6 1.3 17.2 9.5 11.6 1.8 16.1 7.6 312 0 312 165 0.8 0 1.1 0.7 10/25/2006 09:20:00 16.4 1.7 19.9 11.8 16.3 1.8 20.2 11.8 14 2.3 19.5 9.1 312 0 311 165 0.9 0 1.4 0.9 10/25/2006 09:30:00 15.5 1.7 20.2 11.5 15.4 1.7 19.9 11.5 13.2 1.9 18.7 8.8 312 0 311 165 1.1 0 1.4 0.9 10/25/2006 09:40:00 16.4 1.6 21.4 11.8 16.3 1.6 20.6 11.8 14.3 2.2 23.3 9.5 312 0 311 165 1 0 1.4 0.9 10/25/2006 09:50:00 15.9 1.8 20.6 11.5 15.8 1.9 20.6 11.1 13.3 2 18.3 9.1 311 0 312 165 1.2 0.1 1.6 0.9 10/25/2006 10:00:00 16.7 1.6 21 12.2 16.6 1.6 20.2 11.1 13.8 1.7 20.2 9.9 311 0 311 165 1.5 0 1.8 1.4 10/25/2006 10:10:00 14.9 1.9 21.4 9.1 14.9 1.9 21 9.1 12 2 17.9 7.6 299 9 311 165 1.5 0 1.8 1.4 10/25/2006 10:20:00 14.2 1.7 17.6 10.3 14.2 1.7 17.6 10.3 11.6 1.9 17.6 7.2 293 7 287 165 1.4 0.1 1.8 1.4 10/25/2006 10:30:00 12.8 1.5 17.6 9.1 12.8 1.5 17.2 9.1 10.8 1.9 17.6 6.8 297 10 280 165 1.3 0 1.8 1.4 10/25/2006 10:40:00 13 1.4 16.1 9.1 12.9 1.4 16.8 8.8 11.5 1.7 16.1 7.2 306 9 300 165 1.4 0 1.6 1.4 10/25/2006 10:50:00 14.1 2.2 20.2 9.9 14 2.2 19.9 9.9 12.8 2.3 18.3 7.2 310 6 310 165 1.8 0.1 2.3 1.6 10/25/2006 11:00:00 15.6 1.9 20.2 10.7 15.5 1.9 20.2 10.7 14.1 2.1 18.3 9.1 309 7 302 165 2 0 2.3 1.8 10/25/2006 11:10:00 15.2 2.2 21 10.3 15 2.1 21 9.9 13.5 2.4 21.4 8 306 9 316 165 2.1 0 2.6 1.6 10/25/2006 11:20:00 16.9 2 22.1 9.9 16.8 2 22.1 10.3 15 2.5 21 9.9 308 7 305 165 2 0 2.6 1.6 10/25/2006 11:30:00 17.3 2.5 23.7 10.3 17.1 2.5 22.9 9.9 15.3 2.7 22.6 9.5 307 9 297 165 2 0 2.3 1.6 10/25/2006 11:40:00 19 2.9 25.6 11.8 18.8 2.9 26 12.2 16.6 2.9 24 9.5 307 9 302 165 2 0 2.3 1.8 10/25/2006 11:50:00 22.7 2.4 28.7 17.2 22.5 2.5 27.9 17.2 19.3 2.9 26.3 11.8 303 8 309 165 1.9 0.1 2.3 1.4 10/25/2006 12:00:00 20.2 2.4 26 14.5 20.1 2.4 25.2 14.1 16.6 2.5 24 11.8 302 9 282 165 1.9 0.1 2.3 1.4 10/25/2006 12:10:00 19.4 2.4 24.8 13 19.3 2.4 25.2 13 15.9 2.3 22.6 10.3 300 8 293 165 1.9 0 2.1 1.6 10/25/2006 12:20:00 16.9 1.7 22.6 12.2 16.8 1.8 22.9 12.2 14.2 2.2 21.4 9.1 304 9 293 165 2 0 2.3 1.6 10/25/2006 12:30:00 17.4 2.8 22.9 10.3 17.3 2.9 23.3 10.7 13.9 2.6 21 8 300 8 314 165 1.7 0.1 2.3 1.4 10/25/2006 12:40:00 16.2 2.4 22.9 10.3 16.1 2.4 22.9 9.9 13.3 2.3 19.9 8.8 299 9 292 165 1.9 0 2.3 1.6 10/25/2006 12:50:00 18.9 2 23.7 13 18.9 2 23.7 13 15.6 2.4 23.3 9.9 300 8 282 165 1.9 0.1 2.3 1.4 10/25/2006 13:00:00 18.3 2.5 23.3 12.6 18.3 2.5 23.3 11.8 14.5 2.4 22.1 9.1 300 8 302 165 1.7 0.2 2.1 0.9 10/25/2006 13:10:00 19.2 1.9 23.3 13.7 19.1 2 23.7 13.3 14.9 2.3 22.9 10.3 298 7 298 165 1.9 0.1 2.1 1.4 10/25/2006 13:20:00 18.7 1.9 23.3 13.7 18.6 1.9 23.7 13.7 15 2.3 21.4 10.7 300 8 298 165 1.9 0.1 2.3 1.4 10/25/2006 13:30:00 18.3 1.8 23.3 14.5 18.2 1.8 23.3 14.9 14.6 2.4 21.8 9.5 302 7 297 165 2.1 0 2.3 1.6 10/25/2006 13:40:00 17.8 2.2 23.3 13.3 17.8 2.2 23.3 13.3 14.7 2.3 20.6 9.1 304 7 308 165 2.3 0 2.6 1.8 10/25/2006 13:50:00 17.5 1.9 22.6 12.2 17.4 1.9 22.1 11.8 14.2 2.4 21.8 9.5 302 8 298 165 2.1 0.1 3 1.8 10/25/2006 14:00:00 16.4 2.3 22.6 11.5 16.3 2.4 22.6 11.1 13 2.3 20.6 8 304 7 302 165 2 0.1 2.3 1.6 10/25/2006 14:10:00 14.8 1.9 20.2 9.9 14.8 1.9 20.2 10.3 11.9 2 19.5 8 299 9 292 165 1.7 0.2 2.3 1.4 10/25/2006 14:20:00 15.6 2.3 19.9 7.6 15.5 2.4 19.9 8 12.4 2.1 18.3 7.2 300 8 297 165 2 0.3 2.6 1.4 10/25/2006 14:30:00 13.6 1.9 19.1 9.5 13.6 1.9 19.1 9.9 11.2 2 16.4 7.2 298 9 287 165 2.1 0.2 2.8 1.6 10/25/2006 14:40:00 14.5 1.8 18.3 9.5 14.4 1.8 18.3 9.5 11.9 2 17.6 7.6 302 9 310 165 2.1 0.2 2.6 1.6 10/25/2006 14:50:00 15.5 1.9 20.6 11.5 15.3 1.9 20.6 11.5 12.5 1.8 17.2 8.4 302 9 298 165 2.1 0.1 2.6 1.6 10/25/2006 15:00:00 14.2 2.4 21 7.2 14 2.3 21 7.6 12 2 17.9 8 307 9 307 165 2.3 0.1 2.6 1.8 10/25/2006 15:10:00 11.6 2.6 17.6 5.7 11.5 2.5 17.6 5.7 9.8 2.3 16.1 4.9 304 12 305 165 2.2 0.1 2.6 1.8 10/25/2006 15:20:00 10.4 2.3 17.2 5.7 10.3 2.3 16.8 5.7 8.8 2 15.3 5.3 300 10 307 165 2.3 0 2.6 1.8 10/25/2006 15:30:00 12.4 2.3 17.9 6.8 12.2 2.2 17.9 6.8 10.9 1.8 16.8 6.5 308 9 301 165 2.3 0 2.6 2.1 10/25/2006 15:40:00 11.7 2.3 18.3 6.5 11.5 2.4 17.9 7.2 9.6 1.8 15.6 6.1 303 9 309 165 2.1 0 2.6 1.8 10/25/2006 15:50:00 12.3 2.1 17.6 8.4 12.3 2 17.6 8 10.5 2.1 16.8 6.5 304 10 307 165 2.1 0 2.6 1.8 10/25/2006 16:00:00 12.6 2.5 19.5 6.5 12.5 2.5 19.5 6.5 10 2.2 16.8 5.3 299 8 290 165 2.1 0.1 2.6 1.6 10/25/2006 16:10:00 14.1 1.7 19.5 9.1 14 1.7 19.1 8.4 11 1.7 18.3 7.2 300 9 308 165 2.1 0 2.6 1.6 10/25/2006 16:20:00 13.6 2.1 18.7 7.2 13.5 2.1 18.7 7.6 11 1.7 16.1 7.2 301 9 296 165 2.1 0 2.3 1.8 10/25/2006 16:30:00 14.8 2.9 20.6 5.3 14.7 2.9 20.6 4.9 11.9 2.3 17.9 7.2 303 10 301 165 1.9 0 2.3 1.8 10/25/2006 16:40:00 16.3 2 21.4 11.1 16.2 2.1 21.8 10.7 13.5 2.3 21 8.4 306 8 303 165 1.5 0.1 1.8 1.1 10/25/2006 16:50:00 14.1 2 19.5 9.5 13.9 2 18.7 9.9 12.2 2.1 18.7 7.2 307 8 316 165 1.5 0 1.8 1.1 10/25/2006 17:00:00 15.4 2.3 21.4 9.1 15.3 2.3 21.8 9.1 12.8 2.2 19.5 6.5 307 8 304 165 1.4 0.1 1.8 0.9 10/25/2006 17:10:00 14.4 1.7 18.3 9.9 14.3 1.7 18.3 9.5 12.2 1.9 17.6 8 308 7 310 165 1.3 0.1 1.6 0.9 10/25/2006 17:20:00 13.3 1.6 17.2 9.1 13.2 1.6 17.2 8.4 11 1.8 16.8 6.8 305 8 308 165 1.2 0 1.4 0.9 10/25/2006 17:30:00 12.4 1.7 19.5 8.4 12.2 1.7 18.7 8.4 10.9 2.1 18.7 6.5 306 11 308 165 1.1 0 1.4 0.4 10/25/2006 17:40:00 14.6 2.8 21.8 9.1 14.5 2.8 21.4 9.1 12.3 3.1 20.2 6.8 304 9 310 165 1.1 0 1.4 0.9 10/25/2006 17:50:00 10.3 1.3 15.3 7.6 10.3 1.3 15.3 6.8 8.6 1.5 13.7 5.7 297 9 298 165 1 0.1 1.4 0.9 10/25/2006 18:00:00 9.7 2.2 15.6 5.3 9.7 2.2 15.6 5.7 8.2 2.2 15.3 3.8 298 12 283 165 0.9 0 1.1 0.7 10/25/2006 18:10:00 11.4 1.7 16.4 6.5 11.3 1.7 16.4 6.1 9.6 1.7 13.3 4.6 302 11 297 165 0.8 0 1.1 0.7 10/25/2006 18:20:00 13.7 1.6 18.3 9.5 13.6 1.6 17.9 9.1 11.7 2.1 17.6 6.8 305 9 304 165 0.9 0 1.4 0.9 10/25/2006 18:30:00 13 1.7 16.4 8.4 12.8 1.7 16.4 8.4 10.5 1.8 16.8 6.5 298 9 293 165 0.9 0 1.4 0.9 10/25/2006 18:40:00 13.3 1.8 18.7 9.5 13.2 1.8 18.7 9.1 11.5 2.3 19.1 7.2 302 11 307 165 0.9 0 1.4 0.9 10/25/2006 18:50:00 15.6 2.6 23.3 10.3 15.5 2.7 23.3 10.3 12.3 2.2 18.7 7.6 298 8 302 165 0.9 0 1.4 0.9 10/25/2006 19:00:00 14.4 2.4 19.5 8.8 14.4 2.4 19.5 8.4 10.9 1.9 16.1 6.5 298 7 296 165 0.9 0 1.4 0.9 10/25/2006 19:10:00 11.8 1.7 15.6 6.5 11.7 1.7 15.6 6.5 9.9 1.9 15.6 6.1 295 10 301 165 0.8 0 1.4 0.7 10/25/2006 19:20:00 12.7 1.9 17.9 8.4 12.7 1.9 18.3 8.4 10.7 2.5 17.2 6.1 295 9 293 165 0.7 0.1 1.1 0.7 10/25/2006 19:30:00 11.9 1.5 16.1 9.1 11.9 1.5 15.6 8.4 10.1 1.8 14.5 6.8 293 10 308 165 0.8 0 1.1 0.7 10/25/2006 19:40:00 12.4 1.6 16.8 9.1 12.3 1.6 16.8 8.8 10.4 1.7 15.6 6.5 301 10 287 165 0.7 0 0.9 0.7 10/25/2006 19:50:00 13.3 2 17.9 9.1 13.3 2 17.9 9.5 12.1 2.6 17.6 6.8 289 9 290 165 0.8 0 1.1 0.7 10/25/2006 20:00:00 13.3 1.8 19.1 9.5 13.3 1.8 19.1 9.5 11.5 2.4 17.2 6.8 291 7 270 165 0.8 0 1.1 0.7 10/25/2006 20:10:00 12.9 1.7 18.3 9.5 12.8 1.7 18.3 9.5 10.9 2.1 16.4 6.8 291 9 296 165 0.7 0 0.9 0.7 10/25/2006 20:20:00 12.5 1.8 16.8 7.6 12.5 1.8 16.4 7.6 10.6 2 16.8 6.5 291 10 289 165 0.7 0 1.1 0.7 10/25/2006 20:30:00 12.5 1.8 18.3 8.4 12.4 1.8 17.9 8.4 10.4 1.9 15.3 6.1 296 12 284 165 0.8 0 1.1 0.7 10/25/2006 20:40:00 11.8 1.6 16.1 8.4 11.7 1.6 15.6 8 9.8 1.8 15.6 5.7 304 10 309 165 0.7 0 1.1 0.4 10/25/2006 20:50:00 12.4 2.1 17.2 8.8 12.3 2 17.2 8.4 10.2 2.1 17.2 6.5 301 9 310 165 0.8 0 1.1 0.7 10/25/2006 21:00:00 11.7 1.8 17.2 8 11.7 1.8 17.6 8 9.9 2.3 16.4 5.7 298 12 287 165 0.8 0 1.4 0.7 10/25/2006 21:10:00 13.7 2 19.9 8.8 13.6 2 19.5 8.4 11.7 1.9 19.1 7.2 307 8 306 165 0.7 0 0.9 0.7 10/25/2006 21:20:00 13.2 2 21 7.2 13.1 2 20.2 7.2 10.9 2 17.2 5.7 300 9 291 165 0.8 0 1.1 0.7 10/25/2006 21:30:00 13.7 2.6 18.7 7.2 13.6 2.7 18.7 6.5 11.4 2.6 17.9 5.7 301 11 301 165 0.8 0 1.4 0.7 10/25/2006 21:40:00 12.9 2.4 18.7 5.7 12.8 2.4 19.1 6.5 10.7 2.3 16.4 4.9 297 11 305 165 0.7 0 1.1 0.4 10/25/2006 21:50:00 9.8 1.6 13.3 5.3 9.7 1.6 13.3 5.3 8.3 1.6 13 4.2 301 12 293 165 0.4 0.1 0.9 0.2 10/25/2006 22:00:00 9.5 2 14.5 5.3 9.4 2 14.5 5.7 7.9 2 15.3 4.6 300 12 323 165 0.3 0 0.7 0.2 10/25/2006 22:10:00 10.7 2 14.5 5.3 10.7 2 14.5 5.7 10 2.2 15.3 4.9 284 9 291 165 0.3 0 0.7 0.2 10/25/2006 22:20:00 8.4 1.8 13.3 3.4 8.4 1.8 13 3.4 7.3 1.8 11.8 2.3 291 13 262 165 0.2 0 0.7 -0.1 10/25/2006 22:30:00 7.7 1.7 12.2 3 7.9 1.6 12.2 3 7.4 1.7 11.8 2.6 282 12 285 165 0.1 0 0.7 -0.1 10/25/2006 22:40:00 6.4 1.8 11.5 3 6.6 1.7 11.8 2.6 6 1.8 11.8 2.6 284 15 278 165 0 0 0.2 -0.1 10/25/2006 22:50:00 5.8 1.3 9.5 3 6 1.3 9.5 2.6 5.8 1.3 8.8 2.6 274 12 289 165 0.2 0 0.4 -0.1 10/25/2006 23:00:00 6.6 1.3 9.9 3.4 6.8 1.3 10.3 3.4 6.4 1.5 10.3 3 277 9 266 165 0 0 0.7 -0.1 10/25/2006 23:10:00 7.9 1.1 11.1 5.3 7.8 1.1 11.1 5.3 7.3 1.2 10.7 4.6 287 9 284 165 0 0 0.4 -0.1 10/25/2006 23:20:00 7.5 1.1 10.7 4.9 7.5 1.1 10.3 4.9 6.4 1.2 9.5 3.8 295 9 278 165 -0.1 0.1 0.2 -0.3 10/25/2006 23:30:00 8.2 1 12.2 5.7 8.2 1 11.8 5.7 6.7 1 9.1 4.6 302 7 296 165 -0.1 0 0.2 -0.3 10/25/2006 23:40:00 10.2 1.8 14.5 5.7 10.2 1.8 14.9 5.3 8.5 2 14.1 4.2 294 9 290 165 0 0 0.2 -0.3 10/25/2006 23:50:00 9.5 1.3 13.3 7.2 9.5 1.3 13 6.8 7.8 1.4 12.6 5.3 302 9 282 165 0 0 0.4 -0.3 10/26/2006 00:00:00 10 1.2 13 6.5 10.1 1.2 13 6.5 9.1 1.5 13 5.7 289 6 285 165 0.1 0 0.2 -0.1 10/26/2006 00:10:00 8.2 1.1 12.2 5.3 8.2 1.1 12.2 5.7 7.1 1.4 11.1 4.2 292 8 285 165 0.1 0 0.2 -0.3 10/26/2006 00:20:00 7.8 1.7 11.8 4.9 7.8 1.7 11.8 4.9 6.6 1.4 10.3 3.8 294 9 295 165 0.1 0 0.7 -0.1 10/26/2006 00:30:00 8.2 1.5 11.8 4.9 8.1 1.5 11.5 4.9 6.8 1.3 10.7 3.8 298 8 300 165 0.2 0 0.7 -0.1 10/26/2006 00:40:00 8.6 1.1 11.1 4.9 8.4 1.1 11.1 5.3 7.4 1.5 11.8 4.2 303 11 313 165 0.1 0 0.2 -0.1 10/26/2006 00:50:00 9.1 1.2 12.2 6.1 9 1.3 11.8 5.7 7.8 1.5 12.6 4.9 302 9 314 165 0.2 0 0.7 0.2 10/26/2006 01:00:00 9.8 1.8 14.1 6.5 9.8 1.8 14.1 6.5 8.3 1.7 12.6 4.6 297 10 287 165 0.3 0 0.7 0.2 10/26/2006 01:10:00 8.3 1 11.5 6.1 8.2 1.1 11.5 5.7 7.1 1.3 11.8 4.2 295 9 307 165 0.1 0 0.7 -0.1 10/26/2006 01:20:00 9.4 2.1 15.6 4.9 9.3 2.1 16.1 4.6 7.7 1.8 16.1 3.4 306 9 304 165 0 0 0.2 -0.1 10/26/2006 01:30:00 11.5 1.9 16.8 8 11.3 1.9 16.4 7.6 10.4 2.1 16.1 5.3 310 9 310 165 0.2 0 0.7 -0.1 10/26/2006 01:40:00 12.9 1.8 16.8 8.4 12.7 1.8 16.4 8.4 10.7 1.8 16.8 7.2 306 10 310 165 0.3 0 0.7 0.2 10/26/2006 01:50:00 11.7 1.8 15.6 7.2 11.6 1.8 16.4 7.2 9.2 1.8 14.1 4.9 303 9 320 165 0.4 0 0.7 0.2 10/26/2006 02:00:00 8.5 1.2 12.2 5.7 8.4 1.2 12.2 5.3 7.7 1.3 11.5 4.6 309 8 315 165 0.3 0.1 0.9 0.2 10/26/2006 02:10:00 8.7 1.3 12.2 5.3 8.5 1.3 11.8 4.9 7.5 1.5 12.6 4.2 308 9 320 165 0.2 0 0.2 -0.1 10/26/2006 02:20:00 11.3 2 16.4 6.8 11.1 2 16.1 6.5 9.8 2 14.5 6.5 307 10 312 165 0.2 0.1 0.7 -0.1 10/26/2006 02:30:00 11.1 1.5 15.6 6.5 11 1.5 15.6 6.5 9 1.5 13.7 6.1 304 9 302 165 0.4 0 0.9 0.2 10/26/2006 02:40:00 13.9 1.9 18.3 8 13.9 2 18.3 7.6 11.3 1.9 17.9 7.2 301 9 296 165 0.1 0.1 0.7 -0.1 10/26/2006 02:50:00 12.4 1.9 17.9 8 12.3 1.9 17.6 8 10.2 2.4 17.2 6.1 305 8 307 165 0.4 0 0.7 0.2 10/26/2006 03:00:00 9 1.3 13 6.1 8.9 1.3 13 6.1 7.6 1.2 10.7 4.9 301 9 305 165 0.3 0.1 0.9 -0.1 10/26/2006 03:10:00 9.6 1.5 15.3 6.5 9.5 1.5 14.5 6.5 8.1 1.7 13.3 4.9 299 10 293 165 0.2 0 0.4 -0.1 10/26/2006 03:20:00 12.7 1.3 16.4 9.5 12.7 1.3 16.4 9.5 10.2 1.5 14.5 6.5 305 8 308 165 0.4 0 0.7 0.2 10/26/2006 03:30:00 10.2 1.6 15.3 6.8 10.2 1.5 15.3 6.8 8.6 1.7 14.9 5.3 302 8 296 165 0.2 0 0.7 0.2 10/26/2006 03:40:00 11.9 1.9 16.8 7.6 11.8 1.8 16.4 7.6 10 2 14.5 6.1 305 8 307 165 0.2 0 0.4 0.2 10/26/2006 03:50:00 12.3 1.8 19.5 8.4 12.2 1.7 19.9 8.8 10.8 2 18.3 6.5 308 8 301 165 0.2 0 0.7 0.2 10/26/2006 04:00:00 11.4 1.7 16.8 6.8 11.3 1.7 16.8 7.2 9.9 2.1 15.6 5.3 305 9 302 165 0.2 0 0.7 -0.1 10/26/2006 04:10:00 12.8 1.7 17.2 7.6 12.9 1.7 17.2 8 10.9 2.5 19.5 5.3 293 9 290 165 0.2 0 0.7 -0.1 10/26/2006 04:20:00 12.9 1.3 17.2 9.1 12.8 1.3 16.8 9.1 10.6 1.8 15.6 6.8 301 10 284 165 0.1 0 0.7 -0.1 10/26/2006 04:30:00 13.6 2.1 19.5 8.4 13.5 2.1 19.5 8 11.8 1.9 17.9 7.2 307 8 300 165 0.2 0.1 0.7 -0.1 10/26/2006 04:40:00 11.8 1.7 16.8 8.4 11.7 1.7 16.4 8.4 10.3 2 17.2 6.8 307 7 313 165 0.2 0 0.7 0.2 10/26/2006 04:50:00 13 1.3 16.1 9.9 12.9 1.2 16.1 9.9 10.9 1.7 16.8 6.8 305 6 300 165 0.2 0 0.7 -0.1 10/26/2006 05:00:00 11.9 2 17.2 7.2 11.8 1.9 17.6 7.2 9.9 1.9 16.4 6.1 303 8 311 165 0.1 0 0.7 -0.1 10/26/2006 05:10:00 11.9 1.5 15.6 8.4 11.8 1.5 15.6 8 10.3 1.9 16.4 6.1 308 7 304 165 0.1 0 0.4 -0.1 10/26/2006 05:20:00 11.4 1.5 14.9 6.8 11.3 1.5 14.9 6.8 9.9 1.6 14.9 6.1 307 9 311 165 0.1 0 0.4 -0.1 10/26/2006 05:30:00 11.9 1.8 17.6 8 11.8 1.8 17.2 7.6 10 1.9 16.8 6.1 305 8 316 165 0.1 0 0.7 -0.1 10/26/2006 05:40:00 11.4 1.7 16.1 6.8 11.3 1.7 15.6 6.8 9.5 1.8 14.1 5.7 302 8 305 165 0 0 0.2 -0.1 10/26/2006 05:50:00 13.3 1.6 17.6 9.1 13.2 1.6 17.2 9.1 10.7 1.8 16.4 6.5 303 7 303 165 0.1 0 0.4 -0.1 10/26/2006 06:00:00 14.9 1.5 19.1 10.7 14.7 1.5 19.1 10.7 12.4 2.3 18.7 8 306 7 305 165 0.1 0 0.7 -0.1 10/26/2006 06:10:00 13.7 1.8 19.1 9.9 13.6 1.7 19.1 9.5 11.7 2.1 16.4 8 305 8 302 165 0 0 0.4 -0.1 10/26/2006 06:20:00 14.3 1.4 18.7 11.1 14.2 1.4 18.3 10.7 11.7 1.7 16.8 8 306 7 312 165 0 0 0.4 -0.1 10/26/2006 06:30:00 14.9 1.4 19.9 11.8 14.8 1.4 19.5 11.5 11.7 1.7 17.6 7.6 302 7 304 165 0 0 0.2 -0.1 10/26/2006 06:40:00 13.6 1.5 16.8 9.9 13.6 1.5 16.8 9.9 10.6 1.6 15.6 7.2 301 7 304 165 -0.1 0 0.4 -0.1 10/26/2006 06:50:00 14.6 1.3 17.9 10.7 14.6 1.3 17.6 10.3 11 1.3 15.6 8 301 6 300 165 -0.1 0 0.2 -0.1 10/26/2006 07:00:00 14.8 1.2 17.6 10.3 14.7 1.3 17.6 10.3 10.9 1.4 14.5 7.2 299 6 302 165 -0.1 0 0.2 -0.1 10/26/2006 07:10:00 14.5 1.6 19.1 10.7 14.4 1.6 19.1 11.1 11.4 1.6 16.4 8.4 298 7 295 165 -0.2 0 0.2 -0.3 10/26/2006 07:20:00 14.4 1.7 17.9 8.8 14.3 1.7 18.3 8.4 11 1.4 14.9 6.5 299 6 300 165 -0.2 0 0.2 -0.3 10/26/2006 07:30:00 13.2 1.6 17.6 8.8 13.2 1.6 17.9 8.4 10.3 1.5 14.5 6.8 301 8 305 165 -0.2 0.1 0.2 -0.3 10/26/2006 07:40:00 13.3 1.7 16.4 9.5 13.2 1.7 16.4 9.5 10.5 1.7 14.1 6.5 299 7 301 165 -0.3 0 -0.1 -0.5 10/26/2006 07:50:00 13 1.7 16.8 8 12.9 1.7 16.4 7.6 9.8 1.5 14.1 6.5 298 6 288 165 -0.2 0 0.2 -0.3 10/26/2006 08:00:00 11.4 1.2 14.5 8.8 11.3 1.2 14.5 8.8 9.1 1.3 13 6.1 303 7 286 165 -0.3 0 0.2 -0.5 10/26/2006 08:10:00 10.6 1.4 14.5 7.2 10.5 1.4 14.5 7.2 8.6 1.3 13 6.1 307 7 304 165 -0.4 0 -0.1 -0.5 10/26/2006 08:20:00 10.3 1.1 13.3 7.2 10.2 1.1 13.3 7.2 8.7 1.3 11.8 4.9 308 6 310 165 -0.3 0.1 -0.3 -0.5 10/26/2006 08:30:00 10.5 1.2 13.7 7.2 10.5 1.2 13.7 7.6 8.3 1.2 11.8 5.7 302 7 286 165 -0.2 0 -0.1 -0.5 10/26/2006 08:40:00 9.4 1.3 13.3 6.1 9.4 1.3 13.3 6.1 7.5 1.4 11.5 4.2 301 8 310 165 -0.1 0 0.2 -0.3 10/26/2006 08:50:00 8.4 1.3 11.5 4.6 8.5 1.3 11.8 5.3 7.3 1.7 11.8 4.2 293 10 265 165 -0.2 0 0.2 -0.3 10/26/2006 09:00:00 8.8 1 11.1 6.1 8.8 1 11.5 6.5 8.1 1.2 11.1 4.9 289 7 305 165 0.1 0 0.4 -0.1 10/26/2006 09:10:00 6.9 1 9.1 4.2 6.9 1 9.1 4.2 6.1 1.3 9.5 3.4 292 7 293 165 0.3 0 0.7 0.2 10/26/2006 09:20:00 8.1 1.5 13.3 5.3 8.1 1.5 13 5.3 7 1.2 11.5 4.2 305 10 312 165 0.5 0 0.9 0.2 10/26/2006 09:30:00 8.2 1.2 11.5 4.9 8.2 1.2 11.5 5.3 7.2 1.4 10.7 4.2 290 8 298 165 0.1 0 0.7 -0.1 10/26/2006 09:40:00 7.7 0.8 9.5 5.3 7.6 0.8 9.5 5.7 6.6 1.2 9.1 4.2 296 9 310 165 0 0 0.2 -0.1 10/26/2006 09:50:00 7.1 1.1 9.9 4.9 7.1 1.1 9.9 4.9 6.1 1.1 9.5 3.4 303 8 302 165 0 0 0.2 -0.1 10/26/2006 10:00:00 8.7 1.3 11.5 5.7 8.6 1.3 11.8 5.7 7 1.3 11.1 4.2 302 9 308 165 -0.1 0 0.2 -0.1 10/26/2006 10:10:00 7.7 1 10.3 4.9 7.5 1 10.3 4.9 6.6 1.2 9.9 4.2 305 11 301 165 0 0 0.2 -0.1 10/26/2006 10:20:00 7.5 1 9.9 4.9 7.4 1 10.3 5.3 6.1 1.1 9.5 3.4 300 8 294 165 -0.1 0 0.4 -0.1 10/26/2006 10:30:00 7.4 1 9.9 5.7 7.3 1 9.5 5.3 6 1 8.8 3.8 303 7 300 165 0.1 0 0.4 -0.1 10/26/2006 10:40:00 8.1 1 9.9 5.3 8 1 10.3 5.3 7 1.1 9.5 4.6 307 8 307 165 0 0 0.4 -0.1 10/26/2006 10:50:00 7.6 1.1 10.7 4.9 7.5 1.1 10.3 4.9 6.8 1.3 9.9 4.2 308 8 310 165 0.2 0.1 0.7 -0.1 10/26/2006 11:00:00 7.5 1.5 11.5 4.9 7.4 1.5 11.1 4.9 6.7 1.3 11.1 4.2 311 8 299 165 0.5 0 0.7 0.2 10/26/2006 11:10:00 8.7 1 10.7 5.7 8.6 1 10.7 5.7 7.4 1.1 10.7 4.9 308 6 316 165 0.2 0 0.7 0.2 10/26/2006 11:20:00 7.9 0.9 10.3 5.7 7.7 0.9 10.3 5.7 7.2 1 9.9 4.6 312 8 302 165 0.1 0 0.7 -0.1 10/26/2006 11:30:00 7.6 1 9.9 5.7 7.5 0.8 9.5 5.7 7.4 0.8 9.1 4.9 318 9 302 165 0 0 0.4 -0.3 10/26/2006 11:40:00 9 1 11.5 6.5 8.9 1 11.1 6.1 8.4 1.2 11.5 5.3 315 7 317 165 -0.3 0 0.2 -0.5 10/26/2006 11:50:00 8.3 0.7 9.9 6.5 8.1 0.7 9.5 6.5 8 0.8 10.3 5.7 318 7 321 165 -0.2 0 0.2 -0.5 10/26/2006 12:00:00 8.2 0.8 10.3 6.1 8 0.8 10.7 6.1 7.8 1 9.9 5.7 316 7 321 165 -0.1 0.1 0.2 -0.3 10/26/2006 12:10:00 6.8 1 9.9 4.6 6.7 1 9.9 4.6 6.7 1.1 9.5 4.2 327 12 327 165 -0.1 0 0.2 -0.3 10/26/2006 12:20:00 5.5 0.5 7.6 4.6 5.5 0.5 7.2 4.2 5.5 0.5 7.2 4.2 334 12 321 165 0.1 0.1 0.7 -0.1 10/26/2006 12:30:00 4.2 0.6 5.7 2.3 3.8 0.9 5.7 1.5 4.3 0.7 5.7 2.6 348 9 360 165 0.7 0.1 0.9 0.4 10/26/2006 12:40:00 2.9 0.6 4.6 1.5 2.6 0.7 4.6 0.7 3.1 0.5 4.6 1.9 346 11 355 165 0.7 0 0.9 0.4 10/26/2006 12:50:00 3.5 0.8 5.3 1.9 3.6 0.8 5.3 1.9 3.6 0.8 5.7 2.3 329 12 323 165 0.6 0.1 1.1 0.2 10/26/2006 13:00:00 5.4 1 7.6 2.3 5.4 1 7.6 2.3 4.9 1.1 7.6 2.6 312 12 313 165 -0.1 0.3 0.7 -0.5 10/26/2006 13:10:00 4.6 1.5 7.2 1.5 4.6 1.5 7.6 1.1 4 1.1 6.8 1.9 312 22 310 165 -0.5 0 -0.1 -0.8 10/26/2006 13:20:00 2.7 1.2 5.7 0.7 2.6 1.4 6.1 0.4 2.9 0.8 5.7 1.9 336 23 287 165 -0.1 0 0.2 -0.3 10/26/2006 13:30:00 4.7 0.8 6.8 2.3 4.8 0.8 6.5 2.3 4.1 0.7 6.1 2.3 304 10 290 165 -0.2 0.1 0.2 -0.3 10/26/2006 13:40:00 3.9 0.5 6.1 2.3 4 0.5 6.1 2.6 3.9 0.6 5.3 2.3 315 11 297 165 -0.3 0 -0.1 -0.5 10/26/2006 13:50:00 3 0.7 4.6 1.1 2.9 0.8 4.6 0.7 3.3 0.6 4.6 1.9 346 20 326 165 -0.3 0 -0.1 -0.5 10/26/2006 14:00:00 3.3 1.7 7.6 0.4 3.1 1.7 6.8 0.4 3.5 1.5 7.2 0.4 346 16 355 165 -0.2 0.1 0.2 -0.5 10/26/2006 14:10:00 4 1.3 6.5 0.7 3.5 1.2 6.8 1.1 4.3 1.2 6.5 1.5 345 15 344 165 -0.5 0 -0.3 -0.8 10/26/2006 14:20:00 4 0.9 6.1 1.9 3.4 0.8 5.3 0.7 4.2 0.8 6.1 2.3 351 10 358 165 -0.5 0 -0.3 -0.8 10/26/2006 14:30:00 5.3 1 7.6 3 4.8 0.9 7.2 2.3 5.3 1.1 8 2.6 347 14 358 165 -0.5 0 -0.1 -0.8 10/26/2006 14:40:00 4.9 1 6.8 2.3 4.4 1 6.8 2.3 5.1 1 7.2 3 352 13 351 165 -0.6 0 -0.3 -0.8 10/26/2006 14:50:00 5.4 1 8 2.6 5.2 1 8 2.6 5.5 1 8 2.6 341 14 350 165 -0.6 0.1 -0.3 -0.8 10/26/2006 15:00:00 4.8 1.2 8.4 2.3 4.9 1.2 8 2.3 4.3 1.1 8 1.9 304 11 304 165 -0.9 0 -0.5 -1.2 10/26/2006 15:10:00 5.8 0.8 8.4 4.2 5.9 0.8 8.4 4.2 4.8 1 9.9 3 299 7 280 165 -1.1 0 -0.8 -1.2 10/26/2006 15:20:00 6 0.9 8.4 3.8 6 0.9 8.4 3.8 5.3 0.9 8.4 3.4 308 6 313 165 -1 0 -0.8 -1.2 10/26/2006 15:30:00 6.2 0.7 8 4.6 6.3 0.7 8.4 4.6 6.1 0.6 7.6 4.6 315 5 310 165 -1 0 -0.8 -1.2 10/26/2006 15:40:00 4.6 0.5 6.1 3 4.7 0.5 6.1 3.4 4.1 0.5 5.7 2.6 306 8 300 165 -1 0 -0.8 -1.2 10/26/2006 15:50:00 7.5 2.1 11.8 3.4 7.4 2 11.8 3.4 6.5 1.7 11.1 3 309 8 307 165 -0.9 0.1 -0.8 -1.2 10/26/2006 16:00:00 9.3 1.2 11.8 6.5 9.1 1.2 11.5 6.1 8.4 1.2 11.1 5.7 315 11 299 165 -0.8 0 -0.5 -0.8 10/26/2006 16:10:00 11 1.2 14.9 6.5 10.9 1.2 14.1 7.2 10.2 1.5 14.1 6.1 316 8 315 165 -0.9 0 -0.5 -1 10/26/2006 16:20:00 9.5 0.9 12.2 7.2 9.3 0.9 12.2 6.8 9.2 1 11.8 5.7 320 7 305 165 -1 0 -0.5 -1.2 10/26/2006 16:30:00 10.1 1.4 14.9 6.1 9.9 1.5 14.5 6.1 9 1 12.2 6.1 315 13 297 165 -1 0 -0.8 -1.2 10/26/2006 16:40:00 11.1 1.5 14.9 7.6 11 1.5 14.9 7.6 10.1 1.3 13.3 6.5 313 9 312 165 -1.2 0 -0.8 -1.4 10/26/2006 16:50:00 11 1.2 13.7 7.6 10.9 1.1 13.7 7.6 10.3 1.1 13.7 7.6 317 8 302 165 -1.3 0 -1 -1.4 10/26/2006 17:00:00 8.8 1 11.1 6.1 8.5 1.2 11.5 5.7 8.4 1.1 11.1 5.7 332 16 344 165 -1.4 0 -1 -1.4 10/26/2006 17:10:00 7.7 1.2 11.1 4.6 7.6 1.2 11.1 4.9 7.6 1.2 11.5 4.2 334 12 336 165 -1.4 0 -1.2 -1.4 10/26/2006 17:20:00 9.4 1.4 13.3 6.5 9.2 1.5 13.3 6.5 8.4 1.2 13 5.3 313 10 305 165 -1.4 0 -1.2 -1.4 10/26/2006 17:30:00 9.4 1.5 14.1 5.7 9.3 1.5 14.1 6.1 8.8 1.3 13.3 6.1 319 12 308 165 -1.3 0 -1 -1.4 10/26/2006 17:40:00 9.1 1.1 13.3 6.8 9 1.1 12.6 6.1 8.8 1.2 11.8 5.3 328 11 334 165 -1.5 0 -1.2 -1.7 10/26/2006 17:50:00 9.2 1.2 11.8 5.7 9.1 1.3 11.8 5.3 9.1 1.3 12.2 5.7 321 9 318 165 -1.6 0 -1.2 -1.7 10/26/2006 18:00:00 10.7 1.5 14.9 7.2 10.6 1.6 14.9 7.2 9.9 1.6 14.9 6.5 318 10 317 165 -1.6 0 -1.2 -1.9 10/26/2006 18:10:00 11.7 1.3 16.4 8.8 11.5 1.3 16.4 8.4 11.1 1.3 14.9 7.6 320 11 308 165 -1.8 0 -1.4 -1.9 10/26/2006 18:20:00 12.4 1.7 17.2 8.8 12.3 1.7 16.8 8.4 11.5 1.7 16.8 7.2 320 10 334 165 -1.8 0 -1.4 -1.9 10/26/2006 18:30:00 11.9 1.2 15.6 8.4 11.7 1.2 15.6 8.4 11.4 1.3 14.5 7.6 320 8 319 165 -1.7 0 -1.4 -1.9 10/26/2006 18:40:00 11.8 1 14.9 8.4 11.6 1 14.5 9.1 11.1 1.2 14.5 8 323 12 330 165 -1.9 0.1 -1.4 -2.1 10/26/2006 18:50:00 11.6 1.6 17.2 7.6 11.4 1.5 17.2 8 10.2 1.6 14.1 6.5 318 11 315 165 -2.1 0 -1.9 -2.1 10/26/2006 19:00:00 12.2 1.5 16.4 7.2 12.2 1.5 16.1 6.8 11.1 1.5 15.3 6.5 321 10 315 165 -2.1 0 -1.7 -2.1 10/26/2006 19:10:00 10.8 1.7 13.7 5.7 10.7 1.7 13.7 5.7 9.2 1.9 14.1 2.6 316 10 318 165 -2 0 -1.7 -2.1 10/26/2006 19:20:00 10.8 1.8 15.3 5.3 10.7 1.8 14.9 6.1 9 2.1 14.1 4.2 314 10 310 165 -2.1 0 -1.7 -2.1 10/26/2006 19:30:00 12 1.8 16.1 7.6 11.9 1.7 16.1 7.2 10.6 2 15.3 6.1 312 8 313 165 -2 0 -1.7 -2.1 10/26/2006 19:40:00 12.1 1.5 15.6 6.8 11.9 1.5 15.3 6.8 10.3 1.5 13.7 6.8 310 8 307 165 -2.1 0 -1.9 -2.1 10/26/2006 19:50:00 11.9 1.3 15.6 8.8 11.9 1.2 15.6 8.4 10 1.5 13.7 4.9 309 7 304 165 -2.1 0 -1.7 -2.1 10/26/2006 20:00:00 10.8 1.7 14.9 6.1 10.8 1.7 14.9 6.5 8.7 2.1 13.7 2.6 307 9 315 165 -2.1 0 -1.7 -2.1 10/26/2006 20:10:00 10.2 1.7 15.6 6.5 10.1 1.6 16.1 6.1 8.7 1.8 14.1 4.9 306 9 304 165 -2 0 -1.7 -2.1 10/26/2006 20:20:00 10.9 1.7 15.6 6.1 10.8 1.7 15.6 6.1 9.9 2 15.3 5.7 311 8 318 165 -2 0 -1.7 -2.1 10/26/2006 20:30:00 11.3 1.5 15.3 6.8 11.1 1.5 15.3 6.8 9.5 1.5 13.3 5.3 308 7 312 165 -2 0 -1.4 -2.1 10/26/2006 20:40:00 11.9 1.4 15.3 7.6 11.7 1.3 14.9 7.6 9.6 1.5 14.9 6.5 303 8 304 165 -2 0 -1.7 -2.1 10/26/2006 20:50:00 11.4 1.3 14.1 8 11.3 1.3 14.5 8 9.1 1.3 13 5.7 298 9 312 165 -2 0 -1.4 -2.1 10/26/2006 21:00:00 12.1 1 14.9 8.8 12 1.1 14.9 8.8 9.5 1.4 13.7 6.5 295 7 287 165 -2 0 -1.7 -2.1 10/26/2006 21:10:00 11.9 1.2 14.9 8 11.8 1.2 14.9 8 9.4 1.4 14.5 6.8 294 8 292 165 -2 0 -1.4 -2.1 10/26/2006 21:20:00 10.6 1.2 13.3 5.7 10.5 1.2 13 6.1 8.8 1.5 13 5.3 294 10 309 165 -2 0 -1.7 -2.1 10/26/2006 21:30:00 11.5 1.4 14.5 7.2 11.4 1.3 14.5 6.8 9.3 1.5 13.3 5.7 294 9 290 165 -2 0 -1.7 -2.1 10/26/2006 21:40:00 11.3 1.6 15.3 7.6 11.2 1.5 15.3 7.2 9.3 1.4 12.6 6.1 292 8 296 165 -2 0 -1.7 -2.1 10/26/2006 21:50:00 12.5 1.5 15.6 8.4 12.4 1.5 15.6 8.4 9.9 1.4 15.3 6.8 295 7 300 165 -2 0 -1.7 -2.1 10/26/2006 22:00:00 13.8 1.5 16.8 9.5 13.7 1.5 16.8 9.5 10.6 1.3 13.7 6.5 296 8 298 165 -1.8 0 -1.4 -1.9 10/26/2006 22:10:00 13.4 1.5 17.9 9.9 13.2 1.5 16.8 9.9 10.6 1.5 14.5 7.2 294 9 294 165 -1.8 0 -1.4 -1.9 10/26/2006 22:20:00 15.5 1.5 18.7 10.3 15.5 1.5 18.7 10.3 11.7 1.6 17.9 8 295 7 295 165 -1.7 0 -1.4 -1.9 10/26/2006 22:30:00 16.3 1.4 20.2 12.6 16.3 1.4 19.9 11.8 12.4 1.6 17.2 9.1 298 7 296 165 -1.6 0 -1.2 -1.7 10/26/2006 22:40:00 15.8 1.3 19.1 11.8 15.7 1.3 18.7 11.8 12 1.3 16.8 8.4 297 9 289 165 -1.6 0 -1.2 -1.7 10/26/2006 22:50:00 16.1 1.2 19.1 12.6 16.1 1.2 19.1 12.2 11.9 1.4 17.9 8.4 296 7 316 165 -1.6 0 -1.2 -1.7 10/26/2006 23:00:00 14.7 1.2 17.2 10.3 14.7 1.2 17.6 10.3 11.7 1.6 16.4 8 292 9 299 165 -1.8 0 -1.2 -1.9 10/26/2006 23:10:00 14.7 1 17.2 11.8 14.8 1.1 17.2 12.2 12 1.7 16.8 8 293 7 288 165 -1.7 0 -1.4 -1.9 10/26/2006 23:20:00 14.1 1.3 17.6 9.9 14.1 1.3 17.2 9.9 11.8 1.6 16.8 8 291 9 291 165 -1.7 0 -1.4 -1.9 10/26/2006 23:30:00 14.8 1.2 17.6 11.5 14.8 1.2 17.6 11.5 11.9 1.6 16.1 8 295 8 289 165 -1.7 0 -1.4 -1.9 10/26/2006 23:40:00 15.7 1.3 19.1 13 15.7 1.3 18.7 12.6 11.8 1.5 16.8 8.4 300 8 302 165 -1.7 0 -1.2 -1.9 10/26/2006 23:50:00 17.1 1.3 19.9 13.3 17 1.4 20.2 12.6 13.4 1.6 17.9 9.9 301 9 301 165 -1.7 0 -1.2 -1.9 10/27/2006 00:00:00 16.5 1.3 19.5 13.3 16.4 1.3 19.9 13.3 12.7 1.5 16.8 9.5 299 9 296 165 -1.7 0 -1.4 -1.9 10/27/2006 00:10:00 18.9 1.4 21.8 14.5 18.8 1.4 21.4 14.1 15.3 1.8 19.1 11.1 305 6 276 165 -1.7 0 -1.4 -1.9 10/27/2006 00:20:00 19.2 1.2 21.8 15.3 19.2 1.2 21.8 14.5 15.4 2 21.4 10.7 305 6 306 165 -1.6 0 -1.2 -1.9 10/27/2006 00:30:00 16.7 1.5 21 13.3 16.6 1.6 21.4 13.3 13.4 1.9 19.5 9.5 302 9 301 165 -1.6 0 -1.2 -1.9 10/27/2006 00:40:00 17.9 1.4 21 14.5 17.7 1.4 21 14.1 15.5 1.8 20.6 10.7 308 8 307 165 -1.6 0 -1.4 -1.9 10/27/2006 00:50:00 18.2 1.5 21.8 13.7 18 1.5 21.8 13.7 16.8 1.8 21.8 12.2 310 8 305 165 -1.7 0 -1.4 -1.9 10/27/2006 01:00:00 17.1 1.7 21.4 11.8 16.9 1.7 21 11.8 15.2 2.2 20.6 10.7 307 9 297 165 -1.8 0 -1.4 -1.9 10/27/2006 01:10:00 18 1.7 22.9 13.7 17.8 1.7 22.6 13.3 15.9 2.3 22.1 9.9 307 7 302 165 -1.8 0 -1.4 -1.9 10/27/2006 01:20:00 16.5 2.2 21 11.1 16.2 2.2 21 10.7 14.7 2.4 20.2 8 308 9 280 165 -1.8 0.1 -1.4 -1.9 10/27/2006 01:30:00 16.1 1.7 21 11.1 15.9 1.7 20.2 10.3 14 2 18.7 8.8 306 10 308 165 -1.9 0 -1.4 -2.1 10/27/2006 01:40:00 16.5 1.7 21 11.5 16.3 1.7 21 11.1 14.8 2.1 20.6 9.5 309 8 316 165 -1.8 0 -1.4 -2.1 10/27/2006 01:50:00 16.9 1.6 21 11.1 16.7 1.6 21.4 11.1 15.1 1.9 19.5 9.9 309 9 316 165 -1.7 0 -1.4 -1.9 10/27/2006 02:00:00 15 1.7 18.7 9.5 14.7 1.7 18.7 9.9 13.1 1.9 17.6 7.6 308 7 302 165 -1.7 0 -1.4 -1.9 10/27/2006 02:10:00 10.9 1.9 15.3 5.3 10.8 1.9 15.3 5.3 9.4 1.7 13.7 4.9 316 15 299 165 -2 0 -1.4 -2.1 10/27/2006 02:20:00 9.2 2.3 15.3 4.2 9 2.2 14.9 4.6 8.4 2 13.3 4.2 325 17 313 165 -1.9 0 -1.4 -2.1 10/27/2006 02:30:00 10.7 1.8 15.3 6.1 9.5 1.9 15.3 4.9 10.1 1.7 13.7 5.3 350 11 360 165 -1.8 0 -1.4 -1.9 10/27/2006 02:40:00 8.1 1.8 13.7 4.2 8.1 1.9 13.3 2.3 7 1.6 12.2 3.4 322 17 317 165 -1.7 0 -1.4 -1.9 10/27/2006 02:50:00 5.8 1.5 9.9 0.7 5.8 1.4 9.1 1.5 4.6 1.5 9.5 1.1 318 22 259 165 -1.6 0 -1.2 -1.7 10/27/2006 03:00:00 6.7 1.7 11.5 2.6 6.8 1.6 12.2 2.3 5.2 1.7 10.7 1.5 304 17 303 165 -1.7 0 -1.2 -1.9 10/27/2006 03:10:00 9.5 1.8 13.3 4.2 9.5 1.8 13 3.8 7.4 1.7 12.6 2.6 295 9 300 165 -1.7 0.1 -1.4 -1.9 10/27/2006 03:20:00 9.4 1.7 13.3 3.8 9.2 1.7 12.6 3.8 7.5 1.6 13 3 298 11 282 165 -1.6 0 -1.2 -1.9 10/27/2006 03:30:00 8.5 1.7 12.6 1.9 8.5 1.7 12.6 4.2 6.2 1.5 9.9 1.9 299 15 287 165 -1.9 0 -1.4 -2.1 10/27/2006 03:40:00 8.7 1.5 12.6 4.6 8.6 1.5 13 4.2 6.8 1.7 9.9 0.7 308 15 267 165 -1.9 0 -1.4 -2.1 10/27/2006 03:50:00 10.7 1.9 14.9 5.7 10.6 1.8 14.9 6.1 9.6 1.9 14.9 4.9 320 14 318 165 -1.8 0.1 -1.4 -1.9 10/27/2006 04:00:00 11.7 1.5 15.6 8 11.6 1.5 16.1 7.6 10.4 1.5 14.9 6.1 320 13 309 165 -1.5 0 -1.2 -1.7 10/27/2006 04:10:00 14.7 1 17.2 11.8 14.4 1 16.8 11.1 13.9 1.1 16.4 9.5 317 8 316 165 -1.4 0 -1.2 -1.7 10/27/2006 04:20:00 13.9 1.2 16.8 11.1 13.6 1.2 16.8 11.1 13.3 1.3 16.4 8.8 316 5 323 165 -1.6 0 -1.2 -1.9 10/27/2006 04:30:00 13 1 15.3 11.1 12.8 0.9 15.3 10.7 12.7 0.9 14.9 10.7 317 4 314 165 -1.7 0 -1.4 -1.9 10/27/2006 04:40:00 11.5 0.9 13.7 9.5 11.4 0.8 13.7 9.5 11.1 1 13.7 8.8 315 4 317 165 -2 0 -1.4 -2.1 10/27/2006 04:50:00 10.3 0.6 12.2 8.8 10.3 0.7 12.2 8.4 9.6 0.7 11.1 7.6 312 5 310 165 -2 0 -1.7 -2.1 10/27/2006 05:00:00 10.4 0.9 13 8.4 10.3 0.9 12.6 8 9.3 0.9 11.8 6.8 311 6 308 165 -2 0 -1.7 -2.1 10/27/2006 05:10:00 11 0.8 13.7 8 10.9 0.8 13.7 8 10.2 1.1 12.6 6.5 312 5 308 165 -1.6 0 -1.4 -1.9 10/27/2006 05:20:00 10.7 0.6 12.2 8.4 10.6 0.7 11.8 8 9.5 0.9 11.8 6.5 311 4 311 165 -1.8 0.1 -1.2 -2.1 10/27/2006 05:30:00 10.6 0.5 12.2 9.1 10.5 0.5 12.2 8.8 9.3 0.6 11.1 7.2 310 3 307 165 -2 0 -1.4 -2.1 10/27/2006 05:40:00 10.8 0.6 12.2 9.5 10.6 0.6 12.2 9.1 10.1 0.8 12.2 8 312 5 307 165 -2.1 0 -1.9 -2.4 10/27/2006 05:50:00 10.5 0.5 11.8 8.8 10.3 0.5 11.5 8.8 9.8 0.8 11.5 7.2 313 5 306 165 -2.2 0 -1.9 -2.4 10/27/2006 06:00:00 10.9 0.7 12.6 8.4 10.7 0.7 12.2 8.4 9.7 1 11.8 6.8 310 5 308 165 -2.1 0.1 -1.9 -2.4 10/27/2006 06:10:00 10.3 1.2 13 6.1 10.1 1.2 12.2 6.5 8.7 1.1 11.5 5.7 306 8 305 165 -1.8 0 -1.4 -1.9 10/27/2006 06:20:00 10.6 1 14.5 7.6 10.4 1 14.1 7.6 9.3 1.2 12.6 4.9 310 6 310 165 -1.8 0 -1.4 -1.9 10/27/2006 06:30:00 9.7 1.1 12.6 6.8 9.6 1.1 12.2 6.8 9.1 1.1 11.8 6.5 314 6 308 165 -1.7 0 -1.4 -2.1 10/27/2006 06:40:00 9.6 1.3 12.6 5.3 9.4 1.2 12.2 5.7 8.5 1.1 10.7 5.3 311 8 304 165 -1.9 0 -1.7 -1.9 10/27/2006 06:50:00 9.2 1.2 11.8 6.5 9 1.1 11.8 6.5 8.4 1.1 11.8 4.9 314 7 311 165 -1.9 0 -1.4 -2.1 10/27/2006 07:00:00 10 1 13 7.6 9.8 1 13 7.2 8.7 1.1 11.1 5.3 308 9 306 165 -1.9 0 -1.4 -2.1 10/27/2006 07:10:00 10.6 0.7 12.6 8 10.4 0.8 12.6 8 9.3 1 11.5 6.5 309 7 307 165 -1.7 0 -1.4 -1.9 10/27/2006 07:20:00 9.8 0.7 11.5 8 9.7 0.8 11.5 8 8.9 0.9 11.1 6.5 311 6 310 165 -1.8 0 -1.4 -1.9 10/27/2006 07:30:00 11 1.1 13.7 8.4 10.9 1.1 13.7 8.4 9.7 1 12.2 6.8 310 6 305 165 -1.8 0 -1.4 -2.1 10/27/2006 07:40:00 11.5 1 14.9 8.8 11.3 1 15.3 8.4 10.3 1 12.6 7.2 311 6 307 165 -1.7 0 -1.4 -1.9 10/27/2006 07:50:00 11.4 0.8 13.7 8.8 11.3 0.8 13.7 8.8 10.3 0.9 13 6.8 311 6 304 165 -1.7 0 -1.4 -1.9 10/27/2006 08:00:00 11.1 1.2 14.9 8 10.9 1.2 14.9 8 10.3 1.1 13.3 8 314 8 302 165 -1.7 0 -1.4 -1.9 10/27/2006 08:10:00 10.4 1.1 13.3 7.6 10.2 1.1 13 7.6 9.7 1.2 13 6.5 318 9 291 165 -1.5 0 -1.2 -1.7 10/27/2006 08:20:00 10.5 1 13.3 7.6 10.3 1 13.3 7.6 10 1.2 13.3 6.8 318 8 330 165 -1.4 0 -1.2 -1.7 10/27/2006 08:30:00 11.3 1.3 14.5 6.8 11.2 1.3 14.1 6.8 9.6 1.2 13 5.7 308 6 310 165 -1.2 0 -1 -1.4 10/27/2006 08:40:00 10.4 1 14.1 7.6 10.2 1 13.3 7.6 8.6 1.2 12.2 6.1 304 9 293 165 -1.3 0 -0.8 -1.4 10/27/2006 08:50:00 11 1 13.3 7.6 10.9 1 13.3 8 9.1 1.3 13 6.5 305 8 309 165 -1 0 -0.8 -1.2 10/27/2006 09:00:00 11.8 0.9 14.1 9.5 11.7 0.9 13.7 9.5 10 1.2 13.7 7.2 307 7 313 165 -0.8 0 -0.5 -1 10/27/2006 09:10:00 10.6 1.2 14.5 7.6 10.4 1.2 14.1 7.6 9.3 1.2 13 5.7 309 7 301 165 -0.7 0 -0.5 -0.8 10/27/2006 09:20:00 9.3 1.2 12.2 6.5 9.2 1.1 12.2 6.1 7.8 1.2 10.7 4.2 302 9 302 165 -0.6 0 -0.3 -0.8 10/27/2006 09:30:00 9.6 1.1 12.6 6.8 9.5 1.1 12.2 6.8 7.6 1.1 11.1 5.3 298 8 306 165 -0.6 0 -0.3 -0.8 10/27/2006 09:40:00 10.8 1.1 13.3 7.2 10.7 1.1 13 7.2 9.5 1.3 12.6 6.1 308 9 318 165 -0.2 0 -0.1 -0.3 10/27/2006 09:50:00 11.2 1.5 14.9 8 11.1 1.4 14.9 8 9.2 1.2 12.2 5.7 305 9 303 165 -0.1 0 0.2 -0.3 10/27/2006 10:00:00 10.1 1.7 15.6 6.1 9.9 1.7 15.3 6.5 8.1 1.3 13 4.6 301 11 298 165 0.2 0.1 0.7 -0.3 10/27/2006 10:10:00 12.4 1.6 16.4 8.8 12.3 1.5 16.1 8.4 9.8 1.6 14.9 5.7 303 11 303 165 -0.1 0 0.2 -0.5 10/27/2006 10:20:00 13.3 1.3 17.6 8.8 13.1 1.3 17.2 8.8 11.6 1.5 15.6 8 310 7 300 165 0.1 0.1 0.4 -0.3 10/27/2006 10:30:00 12.2 1.3 16.8 9.5 12 1.3 16.4 9.1 11.2 1.4 14.9 8 314 8 310 165 0.2 0.1 0.7 -0.3 10/27/2006 10:40:00 11.8 1.3 15.3 8.8 11.5 1.3 14.9 8.4 10.9 1.4 14.1 7.2 313 7 305 165 0.4 0.1 0.7 -0.1 10/27/2006 10:50:00 11.7 1.3 15.6 8.4 11.5 1.3 15.3 8.4 10.5 1.3 14.5 6.5 312 7 316 165 0.5 0 0.9 0.2 10/27/2006 11:00:00 11.9 1.1 14.5 8.4 11.7 1.1 14.1 8.4 10.5 1.5 14.1 6.8 310 9 318 165 0.5 0 0.9 0.2 10/27/2006 11:10:00 12.9 1.1 15.6 9.9 12.7 1.1 15.6 9.5 10.1 1.1 12.6 7.2 304 7 298 165 0.4 0 0.9 -0.1 10/27/2006 11:20:00 13.4 1 16.1 9.9 13.4 1 15.6 10.3 10 1 13 7.2 302 6 297 165 0.4 0 0.7 -0.1 10/27/2006 11:30:00 12.1 1.2 15.3 8.8 12 1.2 15.6 8.4 9.8 1.4 14.5 6.5 302 8 305 165 0.6 0.1 0.9 0.2 10/27/2006 11:40:00 12.5 1 15.6 9.1 12.5 1 15.6 9.1 9.4 1 11.8 6.8 302 6 300 165 0.6 0.2 0.9 0.2 10/27/2006 11:50:00 12.2 1.2 15.6 9.1 12.1 1.2 15.6 9.1 10 1.3 13.7 7.2 301 9 302 165 0.7 0.1 0.9 0.4 10/27/2006 12:00:00 11.5 1.2 14.5 7.6 11.5 1.1 14.1 8 9.4 1.3 13 6.5 304 8 301 165 0.9 0 1.4 0.7 10/27/2006 12:10:00 9.9 0.8 11.8 7.6 9.9 0.8 12.2 7.6 8.3 1.1 11.5 5.7 306 7 317 165 1.2 0 1.4 0.9 10/27/2006 12:20:00 10.4 1.5 13.7 7.2 10.3 1.5 13.7 6.8 8.5 1.2 11.8 5.3 303 10 309 165 1.3 0.1 1.6 0.9 10/27/2006 12:30:00 11.5 1 14.5 9.1 11.4 1 14.1 9.1 9.2 1 11.8 5.7 304 9 301 165 1.2 0 1.6 0.9 10/27/2006 12:40:00 11.7 1.1 14.5 8.4 11.7 1 14.5 8.8 9.5 1.4 13 6.1 304 8 291 165 1.4 0 1.6 1.4 10/27/2006 12:50:00 11.2 1 13.7 8.4 11.1 1 13.7 8 9.5 1 12.2 6.5 306 8 296 165 1.5 0 1.8 1.4 10/27/2006 13:00:00 10.9 1.2 14.1 8.4 10.8 1.1 13.7 8 9.7 1.5 13.3 5.3 310 11 319 165 1.7 0 1.8 1.4 10/27/2006 13:10:00 11.1 1.3 16.4 8.4 11 1.3 15.6 8.4 10.3 1.5 16.1 7.2 314 11 332 165 1.7 0 1.8 1.6 10/27/2006 13:20:00 10.5 1.4 14.1 6.8 10.4 1.4 14.1 6.5 9.9 1.5 13.7 6.5 318 11 312 165 1.9 0 2.3 1.8 10/27/2006 13:30:00 10.1 1.4 14.5 6.8 10 1.4 14.1 6.8 9.5 1.5 13.7 5.7 316 10 323 165 1.9 0 2.3 1.6 10/27/2006 13:40:00 9.1 1.2 12.6 6.1 9.1 1.2 12.2 6.1 8.7 1.2 12.2 5.7 321 13 314 165 2.1 0 2.3 1.8 10/27/2006 13:50:00 9.9 1.2 13 6.1 9.9 1.2 12.6 6.5 9.2 1.5 13 5.3 314 12 328 165 2.1 0 2.6 1.8 10/27/2006 14:00:00 9.9 1.5 13.7 6.8 9.8 1.5 13.3 6.8 9.2 1.4 14.1 5.3 318 13 317 165 2.3 0 2.6 1.8 10/27/2006 14:10:00 10 1.3 13.7 6.5 9.9 1.3 13.3 6.8 9.4 1.3 13.7 6.1 317 9 316 165 2.2 0 2.6 1.8 10/27/2006 14:20:00 10.7 1 13 8 10.6 1 13 7.6 10.1 1.2 13.7 6.5 315 7 321 165 2.1 0.1 2.6 1.8 10/27/2006 14:30:00 11.1 0.9 13.7 8.4 10.9 0.9 13.7 8 10 1 12.6 7.2 312 9 300 165 2 0.1 2.3 1.8 10/27/2006 14:40:00 10.8 1.4 14.9 7.6 10.7 1.3 14.9 7.2 9.7 1.3 13.7 6.1 312 10 302 165 2 0.1 2.3 1.8 10/27/2006 14:50:00 11.4 1.5 15.3 8.4 11.3 1.5 14.9 8 10.1 1.4 15.3 6.8 310 9 297 165 1.8 0 2.3 1.6 10/27/2006 15:00:00 10 1.2 13.7 7.2 9.9 1.2 13.7 7.2 8.8 1.1 12.2 5.3 310 9 295 165 1.9 0.1 2.3 1.6 10/27/2006 15:10:00 9.2 1.4 13 5.7 9.2 1.4 12.6 5.3 8.2 1.5 12.2 5.7 310 10 292 165 2 0.1 2.3 1.8 10/27/2006 15:20:00 7.5 1 9.9 4.9 7.6 1 9.9 5.3 6.8 1 9.5 3.8 311 10 311 165 2.1 0 2.6 1.8 10/27/2006 15:30:00 7 1 9.9 4.2 7.1 0.9 9.5 4.6 6.6 1 9.1 4.6 323 17 336 165 2.2 0 2.6 1.8 10/27/2006 15:40:00 7.1 2.2 11.5 3 7.2 2.1 11.8 3 6.1 1.5 10.7 3 309 15 300 165 2 0.2 2.6 1.6 10/27/2006 15:50:00 5.8 1.1 8.4 3 5.9 1.1 8.4 2.6 5.7 1 8 3 323 12 304 165 2.3 0.1 2.8 1.8 10/27/2006 16:00:00 6.5 1.3 10.7 3.4 6.3 1.2 9.5 3.4 6 1.3 9.9 3 340 17 358 165 2.7 0.1 3 2.6 10/27/2006 16:10:00 8 1.7 12.2 3.8 7.9 1.7 12.6 3.8 7.5 1.5 11.5 4.2 323 16 307 165 2.6 0.2 3 2.1 10/27/2006 16:20:00 8 1.8 13.7 4.2 8 1.7 13.3 4.6 7.5 1.4 11.8 4.2 316 17 295 165 2.3 0.1 2.6 1.8 10/27/2006 16:30:00 7.2 1.4 11.8 3.8 7.2 1.4 11.8 3 6.7 1.2 10.3 3.8 321 19 292 165 2.3 0 2.6 1.8 10/27/2006 16:40:00 7.3 1.5 11.5 4.6 7.2 1.3 11.5 4.2 6.9 1.3 11.1 3.4 332 17 332 165 1.7 0.3 2.3 0.9 10/27/2006 16:50:00 6 1.2 9.5 3 5.9 1.2 9.1 2.6 5.9 1.2 8.8 2.6 335 17 296 165 1 0.1 1.4 0.7 10/27/2006 17:00:00 4.4 1 7.6 1.5 4.4 1.1 8 1.5 4.6 1.1 7.6 1.9 337 15 338 165 0.7 0.2 1.4 -0.1 10/27/2006 17:10:00 2.6 0.9 5.3 1.1 2.8 0.9 5.3 1.1 2.8 0.9 5.3 1.1 329 21 329 165 0.5 0.1 0.7 -0.1 10/27/2006 17:20:00 4.1 1.6 8.8 0.7 4.3 1.5 8.8 1.5 3.8 1.5 8.8 1.1 304 18 319 165 0.4 0 0.7 -0.1 10/27/2006 17:30:00 5.2 1.1 8.4 2.6 5.4 1.1 8.8 3.4 4.5 0.9 8.8 2.6 307 11 285 165 0.6 0 0.9 0.2 10/27/2006 17:40:00 4.5 1.1 7.2 1.5 4.7 1.1 7.2 2.3 3.7 1 6.5 1.1 306 13 308 165 0.2 0.1 0.9 -0.1 10/27/2006 17:50:00 4.1 1.5 7.2 0.4 4.2 1.4 7.2 0.4 3.9 1.5 6.8 0.4 316 38 301 165 0.2 0 0.4 -0.1 10/27/2006 18:00:00 5.4 0.9 7.6 3.4 5.6 0.9 7.6 3.4 5 0.9 8.4 2.6 310 14 297 165 0.5 0.1 0.9 0.2 10/27/2006 18:10:00 6.6 1.3 9.9 3.8 6.6 1.2 9.9 4.2 6 1.5 9.5 2.6 312 13 322 165 0.7 0 0.9 0.4 10/27/2006 18:20:00 7.5 1 11.1 4.9 7.6 1 11.1 5.3 7 1.1 9.9 3.8 316 7 317 165 0.5 0 0.9 0.4 10/27/2006 18:30:00 7.6 1.2 11.5 4.6 7.6 1.1 11.1 4.6 7.1 1.1 10.3 4.6 317 9 311 165 0.7 0.1 0.9 -0.1 10/27/2006 18:40:00 8.1 1.3 11.8 5.3 7.9 1.3 11.5 5.3 7.5 1.2 11.5 4.2 315 8 302 165 0.5 0 0.9 -0.1 10/27/2006 18:50:00 8.4 1.1 11.5 6.1 8.4 1.1 11.5 6.1 7.6 1 10.3 4.9 312 8 281 165 0.6 0 0.9 0.4 10/27/2006 19:00:00 6.9 1.4 9.9 3 6.9 1.3 10.3 3 6 1.4 8.8 2.3 310 9 306 165 0.5 0 0.9 0.2 10/27/2006 19:10:00 6.7 1.2 9.5 4.6 6.7 1.1 9.5 4.6 5.9 1 8.8 3.4 306 10 305 165 0.4 0.1 0.7 0.2 10/27/2006 19:20:00 6.7 1.1 9.5 3.8 6.7 1 9.1 3.8 5.9 1.2 8.8 3 310 9 314 165 0.5 0 0.9 0.4 10/27/2006 19:30:00 5.8 0.9 8.4 3.8 5.8 0.9 8.4 3.8 4.9 0.8 7.6 3 307 8 314 165 0.3 0.2 0.9 -0.1 10/27/2006 19:40:00 6.4 1 9.9 4.2 6.4 1 9.9 4.6 5.8 1.2 9.1 3.4 312 9 305 165 0.2 0.1 0.7 -0.1 10/27/2006 19:50:00 6.9 1 9.9 4.9 7 0.8 9.5 5.3 6.3 1 9.5 4.6 311 9 319 165 0.3 0 0.7 0.2 10/27/2006 20:00:00 6.9 0.5 8.8 5.3 7 0.5 9.1 5.3 6.2 0.8 8.8 4.2 309 7 305 165 0.2 0 0.7 -0.1 10/27/2006 20:10:00 7.3 0.8 9.5 4.9 7.3 0.8 9.1 5.3 5.8 0.8 8.4 4.2 302 6 313 165 0.4 0 0.7 0.2 10/27/2006 20:20:00 6.2 1 9.5 4.2 6.2 1 9.1 4.2 5.3 1.1 8.4 2.6 306 9 307 165 0.4 0.1 0.9 0.2 10/27/2006 20:30:00 5.1 0.8 7.2 3 5.1 0.7 7.2 3.4 4 0.8 6.1 2.3 297 8 301 165 0.1 0 0.7 -0.1 10/27/2006 20:40:00 5.1 0.7 6.5 3.4 5.2 0.6 6.8 3.4 4.3 0.8 6.8 2.6 303 7 311 165 -0.1 0 0.4 -0.3 10/27/2006 20:50:00 5.1 0.5 6.5 3.8 5 0.5 6.1 3.8 4.2 0.6 6.1 2.6 305 5 306 165 0.1 0 0.2 -0.1 10/27/2006 21:00:00 5.2 0.5 6.8 4.2 5.2 0.5 6.8 4.2 4 0.5 6.1 3 303 5 298 165 -0.1 0 0.2 -0.3 10/27/2006 21:10:00 5.6 0.6 7.6 4.2 5.6 0.6 7.2 4.2 4.6 0.5 6.1 3 306 4 302 165 0.1 0 0.4 -0.1 10/27/2006 21:20:00 6.5 0.7 8.8 4.9 6.5 0.7 8.8 4.6 5.3 0.7 7.6 3.8 305 4 299 165 0.1 0 0.4 -0.1 10/27/2006 21:30:00 7.2 0.8 8.8 4.9 7 0.8 8.8 4.9 5.9 0.8 8 3 305 5 308 165 0.2 0 0.7 -0.1 10/27/2006 21:40:00 5.8 0.7 7.6 4.2 5.8 0.6 7.2 4.6 4.8 0.8 6.5 2.6 307 6 301 165 -0.1 0.1 0.4 -0.3 10/27/2006 21:50:00 5 0.8 6.8 3 5 0.9 6.8 2.3 4 0.9 6.5 1.9 305 9 301 165 -0.2 0 0.2 -0.3 10/27/2006 22:00:00 5 0.7 7.2 3 5.1 0.7 7.2 3.4 4.2 0.8 6.1 2.3 305 9 282 165 -0.1 0 0.2 -0.3 10/27/2006 22:10:00 5.4 0.9 8.8 3.8 5.4 0.9 8.4 3.8 4.6 1 8.8 2.6 310 8 316 165 -0.2 0 0.2 -0.3 10/27/2006 22:20:00 5.6 0.9 7.6 3.4 5.6 0.9 7.6 3.4 4.6 1 8.4 1.9 303 8 302 165 -0.1 0 0.2 -0.3 10/27/2006 22:30:00 4.7 1 8 2.6 4.8 1.1 8 2.6 3.8 1 6.1 1.1 305 9 292 165 0 0 0.7 -0.1 10/27/2006 22:40:00 3.8 0.8 5.7 1.5 3.9 0.8 5.7 1.5 2.4 0.9 5.3 0.4 303 12 313 165 0 0 0.4 -0.1 10/27/2006 22:50:00 5.3 1.2 8 3 5.4 1.2 8 3 4.2 1.2 7.2 1.9 308 7 302 165 0.2 0.1 0.4 -0.1 10/27/2006 23:00:00 5.8 1 8.4 3.4 5.8 1 8.4 3.4 5.2 1 8 3 315 7 318 165 0.2 0 0.7 -0.1 10/27/2006 23:10:00 5.5 0.7 7.2 3.8 5.5 0.6 7.2 3.8 5 0.7 6.8 3 316 9 328 165 0.5 0 0.9 0.2 10/27/2006 23:20:00 5 1.2 8.4 2.3 4.9 1.2 8.4 1.9 4.6 1.1 8 1.9 313 8 337 165 0.7 0 0.9 0.2 10/27/2006 23:30:00 4.9 1 7.2 1.9 4.9 1 7.2 1.9 4.1 1 6.5 1.1 310 8 312 165 0.5 0 0.9 0.2 10/27/2006 23:40:00 6.1 0.8 8.4 4.2 6.1 0.8 8.4 4.6 5.1 0.9 7.6 2.6 307 6 313 165 0.6 0 0.9 0.4 10/27/2006 23:50:00 5.9 0.7 8 3.8 5.9 0.7 7.6 4.2 5 0.9 8 2.6 308 8 305 165 0.8 0 1.1 0.7 10/28/2006 00:00:00 6.2 1.1 8.8 3.4 6.2 1 8.4 3.4 5.6 1 8.4 3.4 312 8 319 165 0.9 0.1 1.4 0.9 10/28/2006 00:10:00 6.3 1 9.1 4.2 6.3 0.9 9.1 4.2 5.6 1.2 9.1 2.6 310 8 315 165 1.4 0 1.8 1.4 10/28/2006 00:20:00 5.7 0.7 7.6 4.2 5.8 0.7 8 4.6 5.1 0.8 7.2 3.4 311 8 312 165 1.4 0 1.8 1.4 10/28/2006 00:30:00 5.8 0.7 8.4 4.2 5.9 0.8 8.4 4.2 4.7 0.6 6.5 3.4 302 5 297 165 1.1 0 1.6 0.9 10/28/2006 00:40:00 7.3 0.7 9.5 5.3 7.2 0.7 9.1 5.3 5.5 0.7 8 3.4 301 4 301 165 1.3 0.1 1.6 1.1 10/28/2006 00:50:00 7.3 0.8 9.1 4.6 7.1 0.7 9.1 4.9 5.8 0.7 7.6 3.8 304 4 298 165 1.5 0 1.8 1.4 10/28/2006 01:00:00 6.5 0.8 8 3.8 6.5 0.7 8 4.2 5.8 0.7 7.6 3.8 312 8 312 165 1.5 0 1.8 1.4 10/28/2006 01:10:00 5.3 0.6 6.8 3.8 5.4 0.6 6.8 3.8 4.7 1 6.8 3 307 9 302 165 1.6 0 1.8 1.6 10/28/2006 01:20:00 5 0.5 6.5 3.8 5 0.5 6.5 3.8 4 0.7 6.1 3 304 5 305 165 1.7 0 1.8 1.6 10/28/2006 01:30:00 5.1 0.7 6.8 3.4 5.1 0.7 6.8 3.4 4.7 0.8 6.5 2.6 313 7 322 165 1.5 0 1.8 1.4 10/28/2006 01:40:00 5.7 0.6 7.6 4.2 5.7 0.6 7.6 4.2 5.1 0.8 7.2 2.3 310 8 312 165 1.7 0.1 1.8 1.4 10/28/2006 01:50:00 5.4 0.8 7.6 3.4 5.4 0.7 7.2 3.4 4.5 0.8 6.5 2.6 305 7 307 165 1.7 0.1 2.1 1.4 10/28/2006 02:00:00 6.2 0.6 7.6 4.6 6.2 0.6 7.6 4.2 5.3 0.7 7.2 3.4 307 6 304 165 1.5 0.1 1.8 1.4 10/28/2006 02:10:00 4.8 1 7.2 2.6 4.8 1 7.2 3 4 1 6.1 1.9 302 8 307 165 1.7 0 2.1 1.6 10/28/2006 02:20:00 4.2 0.8 6.1 2.3 4.2 0.8 6.5 2.3 3.5 0.7 5.7 1.9 297 10 307 165 1.4 0.1 1.8 1.4 10/28/2006 02:30:00 4 0.9 6.5 1.5 4.1 0.9 6.8 1.9 3.5 0.8 6.5 1.5 293 11 284 165 1.4 0.1 1.8 1.4 10/28/2006 02:40:00 5.4 1.1 8.4 2.6 5.5 1 8.4 2.6 4.4 0.8 6.5 2.3 297 9 299 165 2 0 2.3 1.8 10/28/2006 02:50:00 5.5 0.7 7.6 3.8 5.6 0.7 7.6 3.8 5.1 1 7.6 3 295 9 310 165 2 0 2.3 1.8 10/28/2006 03:00:00 6.1 0.8 8.8 4.2 6.1 0.8 8.8 4.6 5.2 0.8 7.6 3.4 298 8 310 165 2.1 0 2.6 1.8 10/28/2006 03:10:00 4.9 1.4 8.8 2.6 4.9 1.3 8.8 2.6 4.3 1.3 8 2.3 307 12 314 165 2 0.1 2.6 1.6 10/28/2006 03:20:00 4.5 0.9 7.2 2.3 4.6 0.9 7.6 2.6 4 0.9 6.5 2.3 299 10 297 165 2.4 0.1 2.8 2.1 10/28/2006 03:30:00 5 0.7 7.6 3 5.1 0.7 7.2 3.4 4.3 0.9 7.2 2.3 303 8 302 165 2.4 0 2.8 2.1 10/28/2006 03:40:00 3.9 0.6 5.3 1.9 4 0.7 5.3 1.9 3.4 0.7 5.3 1.5 298 9 291 165 2.1 0 2.6 1.8 10/28/2006 03:50:00 3.7 0.8 5.7 1.9 3.8 0.8 5.7 2.3 3.4 0.9 6.5 1.9 299 12 314 165 1.8 0 2.3 1.6 10/28/2006 04:00:00 5 1 8 2.6 5.1 1 7.6 2.3 4.4 1 8.4 2.3 293 10 292 165 2 0 2.6 1.8 10/28/2006 04:10:00 5.1 1.3 8.4 1.9 5.2 1.5 8.8 1.5 4.3 1.2 7.2 0.4 305 12 297 165 2.2 0.1 2.6 1.8 10/28/2006 04:20:00 3.6 0.8 5.7 1.9 3.7 0.7 5.7 1.9 3.4 0.7 5.7 1.5 312 11 338 165 1.7 0 2.1 1.4 10/28/2006 04:30:00 2.6 1 4.9 0.4 2.8 0.9 4.9 0.7 2.7 0.9 4.9 1.1 301 17 330 165 2.2 0.1 2.6 1.8 10/28/2006 04:40:00 2.9 0.8 4.6 0.4 3.1 0.8 4.9 0.4 2.8 0.6 4.9 0.7 291 11 289 165 2.1 0 2.8 1.8 10/28/2006 04:50:00 4.9 0.6 6.5 3.4 5 0.6 6.8 3.8 4.5 0.7 6.1 2.6 290 7 305 165 2.1 0 2.6 1.8 10/28/2006 05:00:00 5.2 0.8 7.6 2.6 5.3 0.7 7.6 3 4.4 0.7 6.8 2.3 294 8 293 165 2.4 0 2.8 2.3 10/28/2006 05:10:00 4 0.9 6.5 1.9 4.1 0.9 6.5 1.9 3.5 0.8 5.7 1.9 304 12 319 165 2 0.2 2.6 1.4 10/28/2006 05:20:00 3.9 1.1 7.2 1.9 4 1 7.2 2.3 3.4 0.8 6.8 1.5 297 12 313 165 1.8 0.1 2.3 1.6 10/28/2006 05:30:00 4.3 0.6 5.7 2.6 4.4 0.6 5.7 2.6 3.9 0.7 5.7 2.6 298 9 297 165 2.4 0.2 2.8 2.1 10/28/2006 05:40:00 4.6 0.5 6.1 3 4.7 0.5 6.1 3 3.9 0.5 5.3 2.3 301 6 294 165 2.6 0 2.8 2.6 10/28/2006 05:50:00 4.5 0.5 5.7 3.4 4.6 0.5 5.7 3.4 3.8 0.7 5.7 2.6 296 7 292 165 2.5 0.1 2.8 2.3 10/28/2006 06:00:00 3.3 1.4 6.5 0.4 3.3 1.4 6.5 0.4 3.1 0.9 5.7 1.1 308 22 295 165 2.1 0.2 2.8 1.6 10/28/2006 06:10:00 5 0.8 6.8 3 5.1 0.8 6.8 3 4.4 0.7 6.8 2.6 301 8 293 165 2.4 0.2 2.8 1.8 10/28/2006 06:20:00 4.8 0.7 6.8 3.4 4.9 0.7 6.8 3.4 3.9 0.7 6.8 2.6 303 5 304 165 2.4 0 2.8 2.3 10/28/2006 06:30:00 5.3 0.5 6.5 3.8 5.4 0.5 6.8 3.8 4.4 0.6 5.7 3 304 6 303 165 2.6 0 2.8 2.6 10/28/2006 06:40:00 4.9 0.6 6.1 3 5 0.7 6.5 3 4.5 0.6 6.1 2.6 308 4 309 165 2.5 0 2.8 2.3 10/28/2006 06:50:00 5.5 0.6 7.2 4.2 5.7 0.6 7.2 4.2 4.4 0.5 5.7 3 303 4 305 165 2.5 0 2.8 2.3 10/28/2006 07:00:00 6.7 0.4 8 5.7 6.8 0.4 8 5.7 5.3 0.5 6.8 4.2 305 3 307 165 2.4 0 2.8 2.3 10/28/2006 07:10:00 7.1 0.5 8.4 5.7 7 0.5 8.8 5.7 5.8 0.6 7.6 4.2 305 4 303 165 2.6 0 2.8 2.6 10/28/2006 07:20:00 7.2 0.9 9.1 4.6 7.2 0.8 9.1 4.2 5.8 0.9 8 2.6 304 6 302 165 2.6 0 2.8 2.3 10/28/2006 07:30:00 6 0.7 8 4.2 6 0.7 7.6 4.2 4.8 0.7 6.8 3 301 8 297 165 2.6 0 2.8 2.3 10/28/2006 07:40:00 5.6 0.9 7.2 3.8 5.6 0.9 7.6 3.8 4.5 0.7 6.5 2.6 306 8 301 165 2.7 0.2 3.3 2.3 10/28/2006 07:50:00 6.5 0.6 8.4 4.6 6.7 0.6 8 4.9 4.9 0.5 6.5 3.4 301 5 302 165 3 0 3.3 2.8 10/28/2006 08:00:00 5.2 0.6 6.8 2.6 5.4 0.5 7.2 4.2 4.5 0.6 6.1 3 297 11 305 165 3 0.1 3.3 2.8 10/28/2006 08:10:00 4.3 0.6 5.7 2.6 4.5 0.6 5.7 2.6 4.3 0.8 5.7 2.3 283 8 282 165 3.2 0.2 3.8 2.8 10/28/2006 08:20:00 3.1 0.8 5.3 1.5 3.3 0.8 5.3 1.5 3.6 0.8 5.3 1.9 289 11 286 165 4 0.1 4.5 3.8 10/28/2006 08:30:00 3.6 1.1 5.7 0.7 3.8 1.1 6.1 1.5 3.6 1 5.7 1.9 287 10 282 165 3.8 0.2 4.5 3.3 10/28/2006 08:40:00 3.2 1.8 6.1 0.4 3.4 1.8 6.1 0.4 3 1.8 6.5 0.4 269 24 282 165 3.3 0.1 3.8 3.3 10/28/2006 08:50:00 4.2 1.5 6.5 0.4 4.3 1.3 6.5 0.4 3.6 1.2 6.1 0.4 283 13 289 165 4 0 4.3 3.8 10/28/2006 09:00:00 5.1 0.5 6.5 3.4 5 0.5 6.1 3.4 4.5 0.6 5.7 3 287 4 292 165 4.4 0.3 4.8 3.8 10/28/2006 09:10:00 5.1 0.5 6.5 3.4 5.1 0.5 6.5 3.4 4.3 0.7 6.8 3 298 9 290 165 4.6 0.1 5 4 10/28/2006 09:20:00 3.5 1 5.7 1.9 3.5 1 5.7 1.5 2.9 0.8 4.9 1.1 296 7 295 165 5.4 0.3 6.2 4.8 10/28/2006 09:30:00 2 0.7 4.6 0.4 2 0.7 4.2 0.4 2 0.6 4.2 0.4 297 18 315 165 6.3 0.1 6.7 6 10/28/2006 09:40:00 0.9 0.6 3 0.4 1.1 0.6 3 0.4 1.4 0.5 2.6 0.4 262 26 302 165 6.5 0.1 7.3 6 10/28/2006 09:50:00 1.1 0.6 2.6 0.4 1.3 0.8 3 0.4 1.8 0.6 3 0.7 257 29 278 165 6.7 0.1 7 6.2 10/28/2006 10:00:00 1 0.4 1.9 0.4 1.4 0.4 2.3 0.4 1.5 0.3 2.3 0.7 272 7 277 165 6.9 0.1 7.5 6.7 10/28/2006 10:10:00 1.8 0.4 2.6 0.7 2 0.4 2.6 0.7 2.1 0.4 3 1.1 267 9 279 165 6.4 0.1 7.3 6.2 10/28/2006 10:20:00 1.7 0.6 3.4 0.4 1.6 0.6 3.4 0.4 1.9 0.4 3 1.1 223 58 215 165 6.5 0.1 7 6 10/28/2006 10:30:00 1.2 0.6 2.6 0.4 1.1 0.6 3 0.4 1.4 0.6 3 0.4 161 29 151 165 5.2 0.2 6 4.8 10/28/2006 10:40:00 1.8 0.5 3 0.7 1.7 0.5 3 0.7 1.7 0.4 3 0.7 157 22 169 165 5.4 0 5.7 5.2 10/28/2006 10:50:00 2 0.5 3 1.1 2.1 0.5 3 1.1 2.2 0.4 3.4 1.1 204 12 203 165 6.3 0.3 7 5.7 10/28/2006 11:00:00 2.7 0.5 3.8 1.5 2.8 0.5 3.8 1.9 3 0.4 4.2 1.9 196 9 192 165 6.9 0.1 7.3 6.7 10/28/2006 11:10:00 3.2 0.5 4.6 1.5 3.2 0.5 4.6 1.5 3.3 0.5 4.9 1.9 168 8 162 165 7.3 0 7.5 7 10/28/2006 11:20:00 2.6 0.4 3.8 1.1 2.7 0.4 4.2 1.5 2.7 0.4 4.2 1.5 168 9 169 165 7.1 0.1 7.5 7 10/28/2006 11:30:00 2.2 0.6 3.8 0.7 2.2 0.5 3.4 1.1 2.4 0.5 3.8 1.5 175 9 179 165 6.8 0.3 7.5 6.2 10/28/2006 11:40:00 2.5 0.4 3.4 1.5 2.4 0.4 3.4 1.5 2.6 0.4 3.8 1.5 180 8 176 165 6.3 0.3 7 5.7 10/28/2006 11:50:00 1.6 0.5 3 0.4 1.6 0.5 3 0.4 1.8 0.5 3.4 0.7 171 22 136 165 7.8 0.4 8.5 7 10/28/2006 12:00:00 1.3 0.6 3 0.4 1.4 0.6 3 0.4 1.7 0.5 3.4 0.4 161 15 165 165 8.2 0 8.8 8 10/28/2006 12:10:00 1 0.5 2.3 0.4 1 0.6 2.3 0.4 1.3 0.6 2.6 0.4 150 26 148 165 8.5 0.2 9 8.3 10/28/2006 12:20:00 1.1 0.6 2.6 0.4 1.3 0.6 3 0.4 1.7 0.5 3.4 0.4 145 22 154 165 8.5 0.2 9 8 10/28/2006 12:30:00 1.6 0.7 3.8 0.4 1.6 0.8 3.8 0.4 1.9 0.7 3.8 0.4 133 23 145 165 7.4 0.3 8 7 10/28/2006 12:40:00 0.4 0.2 1.5 0.4 0.4 0.1 1.1 0.4 0.4 0.2 1.5 0.4 121 15 116 165 7.6 0.5 8.5 6.7 10/28/2006 12:50:00 0.6 0.3 1.5 0.4 0.5 0.3 1.5 0.4 0.7 0.3 1.5 0.4 12 51 33 165 8 0.1 8.3 7.8 10/28/2006 13:00:00 0.6 0.4 1.5 0.4 0.5 0.2 1.5 0.4 0.6 0.4 1.5 0.4 325 5 325 165 8 0 8.3 7.5 10/28/2006 13:10:00 0.7 0.4 1.5 0.4 0.5 0.3 1.5 0.4 0.7 0.4 1.5 0.4 337 1 338 165 7.8 0 8.3 7.5 10/28/2006 13:20:00 1 0.3 1.9 0.4 0.8 0.4 1.5 0.4 1.1 0.3 1.9 0.7 346 19 338 165 7.9 0 8.5 7.5 10/28/2006 13:30:00 1 0.5 2.3 0.4 0.9 0.5 1.9 0.4 0.9 0.5 2.3 0.4 73 36 62 165 7.1 0.1 7.5 7 10/28/2006 13:40:00 0.6 0.4 1.9 0.4 0.5 0.4 1.9 0.4 0.7 0.4 1.9 0.4 61 51 113 165 7.3 0.2 7.8 6.7 10/28/2006 13:50:00 0.7 0.3 1.5 0.4 0.5 0.3 1.5 0.4 0.7 0.3 1.5 0.4 11 29 4 165 7 0 7.3 6.7 10/28/2006 14:00:00 0.5 0.3 1.9 0.4 0.5 0.3 1.9 0.4 0.7 0.3 1.5 0.4 75 45 349 165 6.9 0 7.3 6.7 10/28/2006 14:10:00 1.3 0.2 1.9 0.7 1.1 0.3 1.9 0.4 1.4 0.2 1.9 0.7 352 16 340 165 6.8 0.2 7.5 6.5 10/28/2006 14:20:00 1.5 0.3 1.9 0.7 1.2 0.3 1.9 0.4 1.5 0.3 2.3 0.7 14 9 28 165 7.5 0 7.8 7.3 10/28/2006 14:30:00 1.3 0.3 1.9 0.4 1.2 0.4 1.9 0.4 1.4 0.3 2.3 0.7 27 17 12 165 7.5 0.2 7.8 7 10/28/2006 14:40:00 1.8 0.6 4.2 0.4 1.9 0.6 4.2 0.4 1.8 0.5 4.2 0.4 72 28 104 165 6.6 0.2 7.5 6.2 10/28/2006 14:50:00 1.4 0.5 2.6 0.4 1.4 0.5 2.6 0.4 1.3 0.5 2.6 0.4 57 24 79 165 6.6 0.1 7 6.2 10/28/2006 15:00:00 1.2 0.5 2.6 0.4 1.2 0.5 2.6 0.4 1.3 0.6 3 0.4 62 61 157 165 6.9 0.1 7.5 6.7 10/28/2006 15:10:00 0.6 0.4 1.9 0.4 0.6 0.4 1.5 0.4 0.9 0.5 2.3 0.4 157 15 165 165 6.7 0.2 7.3 6.2 10/28/2006 15:20:00 0.5 0.3 1.9 0.4 0.5 0.3 1.5 0.4 0.5 0.2 1.1 0.4 340 98 61 165 6.4 0.1 7 6 10/28/2006 15:30:00 1.1 0.5 2.3 0.4 1.2 0.5 2.3 0.4 1.3 0.4 2.3 0.4 114 28 87 165 5.7 0.4 6.7 5.2 10/28/2006 15:40:00 1.8 0.3 2.6 0.7 1.8 0.3 2.6 1.1 1.8 0.3 2.6 1.1 101 8 109 165 4.9 0.2 5.2 4.5 10/28/2006 15:50:00 1.2 0.7 2.3 0.4 1.1 0.6 2.3 0.4 1.2 0.6 2.3 0.4 122 5 115 165 4.6 0 4.8 4.5 10/28/2006 16:00:00 1 0.7 2.3 0.4 1 0.8 2.6 0.4 1 0.7 2.6 0.4 110 19 87 165 4.6 0 4.8 4.3 10/28/2006 16:10:00 2.1 0.5 3 0.7 2.2 0.4 3 1.1 2.3 0.4 3 1.1 90 4 98 165 4.6 0 4.8 4.5 10/28/2006 16:20:00 1.5 0.3 2.3 0.7 1.5 0.4 2.3 0.7 1.8 0.3 2.3 0.7 41 29 357 165 4.5 0 4.8 4.3 10/28/2006 16:30:00 1.7 0.3 2.6 1.1 1.7 0.4 2.6 0.4 2.1 0.2 2.6 1.5 13 15 37 165 4.2 0 4.5 3.8 10/28/2006 16:40:00 1.6 0.5 2.3 0.7 1.6 0.7 2.6 0.4 2 0.4 2.6 1.1 24 19 35 165 4.3 0 4.5 4 10/28/2006 16:50:00 1.3 0.3 1.9 0.4 1.4 0.3 2.3 0.7 1.7 0.3 2.3 1.1 15 26 339 165 4.1 0.1 4.5 3.8 10/28/2006 17:00:00 1.2 0.8 2.6 0.4 1.4 0.8 3 0.4 1.9 0.7 3.4 0.7 61 11 49 165 4.3 0 4.5 3.5 10/28/2006 17:10:00 0.8 0.3 1.5 0.4 0.9 0.4 1.5 0.4 1.3 0.4 1.9 0.4 59 27 41 165 4.4 0 4.5 3.8 10/28/2006 17:20:00 0.8 0.4 1.5 0.4 0.9 0.5 1.5 0.4 1.3 0.5 1.9 0.4 55 22 36 165 4.5 0 4.8 3.8 10/28/2006 17:30:00 1.2 0.7 2.6 0.4 1.3 0.7 2.6 0.4 1.5 0.7 2.6 0.4 117 2 114 165 4.6 0 4.8 4.5 10/28/2006 17:40:00 0.4 0.1 1.1 0.4 0.4 0.2 1.5 0.4 0.5 0.3 1.5 0.4 208 112 344 165 4.4 0 4.8 4.3 10/28/2006 17:50:00 0.5 0.2 1.5 0.4 0.5 0.2 1.5 0.4 0.8 0.4 1.9 0.4 185 98 137 165 4.5 0.2 4.8 4.3 10/28/2006 18:00:00 1.1 0.2 1.5 0.7 1.2 0.2 1.9 0.7 1.5 0.2 1.9 1.1 121 3 116 165 4.6 0 5 4.5 10/28/2006 18:10:00 1.4 0.4 2.3 0.7 1.5 0.4 2.3 0.7 1.7 0.3 2.3 1.1 140 6 145 165 4.5 0 4.8 4.5 10/28/2006 18:20:00 0.9 0.3 1.9 0.4 0.8 0.4 1.5 0.4 1.4 0.3 1.9 0.7 152 4 142 165 4.5 0 4.8 4.3 10/28/2006 18:30:00 0.9 0.4 1.9 0.4 0.8 0.4 1.5 0.4 1.4 0.3 2.3 0.4 153 5 147 165 4.4 0 4.8 4 10/28/2006 18:40:00 1.8 0.3 2.6 1.1 1.7 0.4 2.6 0.7 2 0.2 2.6 1.5 154 5 160 165 4.3 0.2 4.8 3.8 10/28/2006 18:50:00 2.1 0.3 2.6 1.5 1.9 0.3 2.6 1.1 2 0.2 2.6 1.1 178 7 164 165 4.2 0.3 4.8 3.5 10/28/2006 19:00:00 2.4 0.3 3 1.5 2.2 0.3 2.6 1.5 2.3 0.3 3 1.1 180 6 182 165 4.5 0 4.8 3.8 10/28/2006 19:10:00 2.2 0.4 3.4 1.1 2 0.4 3 0.7 2.2 0.3 2.6 1.1 177 5 180 165 4.4 0 4.8 4.3 10/28/2006 19:20:00 2 0.6 3.4 0.4 1.8 0.7 3.8 0.4 2 0.5 3.8 0.7 198 13 202 165 4.4 0 4.8 4.3 10/28/2006 19:30:00 1.9 0.5 3.8 0.7 1.6 0.5 3.8 0.4 2 0.3 3 1.1 181 9 199 165 4.4 0 5 4 10/28/2006 19:40:00 2.9 0.4 4.2 1.9 2.7 0.4 3.8 1.9 2.9 0.4 3.8 1.9 181 8 179 165 4.4 0 4.8 3.8 10/28/2006 19:50:00 3.6 0.5 4.9 2.6 3.4 0.5 4.6 2.3 3.4 0.4 4.6 2.3 181 9 181 165 4.4 0.2 4.8 3.5 10/28/2006 20:00:00 4.6 0.7 6.1 3 4.5 0.6 5.7 3 4.6 0.7 6.1 3 193 8 196 165 4.7 0.1 5 3.8 10/28/2006 20:10:00 4.2 0.5 5.7 3 4.1 0.4 5.7 3 4.2 0.5 6.1 3 180 5 173 165 4.8 0 5 4.8 10/28/2006 20:20:00 4.2 0.8 6.8 2.6 4 0.8 6.5 2.6 4.3 0.7 6.1 3 175 8 169 165 4.9 0.1 5.2 4.5 10/28/2006 20:30:00 4.6 0.5 5.7 3.4 4.4 0.4 5.7 3.4 4.5 0.4 5.3 3.8 171 6 170 165 4.5 0 5 4.3 10/28/2006 20:40:00 5.2 0.5 6.5 3.4 4.9 0.4 6.1 3.4 4.7 0.4 5.7 3.4 177 8 184 165 4.4 0 4.8 4.3 10/28/2006 20:50:00 5.4 0.7 6.8 3.8 5.2 0.7 6.5 3.4 5.2 0.6 6.5 3.8 174 6 179 165 4.6 0 5 4.3 10/28/2006 21:00:00 4.9 0.5 6.5 3.8 4.7 0.5 6.1 3.8 4.7 0.5 6.5 3.4 170 8 158 165 4.4 0.1 4.8 3.8 10/28/2006 21:10:00 5.9 0.6 8 3.8 5.7 0.6 7.2 3.8 5.7 0.7 8 4.2 182 6 187 165 4.5 0.2 5 3.8 10/28/2006 21:20:00 5.9 0.6 6.8 4.2 5.7 0.5 6.8 4.2 6 0.6 7.2 4.6 178 5 177 165 4.9 0 5.2 4.5 10/28/2006 21:30:00 4.8 0.5 6.5 3 4.6 0.5 6.1 3 4.8 0.5 6.1 3.4 180 9 204 165 4.9 0 5.2 4.5 10/28/2006 21:40:00 5.3 0.6 6.8 3.8 5.2 0.6 6.5 3.8 5 0.6 6.8 3.4 188 8 189 165 4.6 0.1 5.2 4.3 10/28/2006 21:50:00 5.7 0.7 7.6 4.2 5.8 0.7 7.6 4.2 5.6 0.7 8 3.8 202 6 207 165 4.8 0 5 4.5 10/28/2006 22:00:00 4.6 0.6 6.8 3 4.7 0.6 6.8 3.4 4.4 0.6 6.5 3 209 7 232 165 4.8 0 5 4.5 10/28/2006 22:10:00 6 1.1 8 3.4 6 1.1 8 3.4 6 1.2 8 3 199 7 200 165 4.8 0.1 5.2 4.5 10/28/2006 22:20:00 7 0.7 8.8 4.9 6.9 0.7 8.8 4.9 7 0.9 8.8 4.6 200 5 199 165 5 0.2 5.2 4.5 10/28/2006 22:30:00 6.8 1.2 9.1 4.2 6.7 1.2 8.8 4.2 6.7 1.2 9.5 4.2 200 6 201 165 5 0.2 5.5 4.5 10/28/2006 22:40:00 5.4 0.8 6.8 3.4 5.4 0.8 6.8 3.4 5 0.8 6.8 2.6 205 8 202 165 4.9 0.2 5.2 4.5 10/28/2006 22:50:00 5.1 0.7 7.2 3 5 0.7 7.2 3 4.9 0.7 7.2 2.6 189 12 200 165 4.8 0.2 5.2 4.3 10/28/2006 23:00:00 5.9 0.7 8 4.2 5.6 0.7 7.6 3.8 5.8 0.6 7.2 4.2 179 8 170 165 5 0 5.5 4.3 10/28/2006 23:10:00 6.4 0.3 7.2 5.7 6.4 0.3 7.2 5.7 6.6 0.5 7.6 5.3 191 3 198 165 4.9 0 5.2 4.3 10/28/2006 23:20:00 6.7 0.4 8 5.7 6.7 0.4 8 5.7 6.8 0.5 8 5.3 192 3 196 165 5.1 0 5.5 4.8 10/28/2006 23:30:00 5.9 0.8 7.6 3.4 5.8 0.8 7.6 3.8 5.9 0.8 7.6 4.2 197 5 197 165 5.2 0.1 5.5 4.5 10/28/2006 23:40:00 6 0.7 8 3.8 5.9 0.6 7.6 4.2 5.9 0.7 7.6 4.2 195 7 190 165 5.2 0 5.5 5 10/28/2006 23:50:00 6 0.7 7.6 3.8 5.8 0.6 7.6 4.2 6 0.7 7.6 4.2 191 6 196 165 5.2 0 5.5 5 10/29/2006 00:00:00 6.2 0.8 8.4 4.6 6.1 0.7 8 4.6 6.3 0.7 8 4.2 190 6 200 165 5.2 0 5.5 5 10/29/2006 00:10:00 5.6 0.6 7.6 3.8 5.4 0.6 7.2 4.2 5.6 0.6 6.8 4.2 194 5 191 165 5.3 0 5.5 5 10/29/2006 00:20:00 5.7 0.5 6.8 4.2 5.5 0.6 6.8 4.2 5.6 0.6 7.2 4.2 200 5 200 165 5.3 0 5.7 4.8 10/29/2006 00:30:00 6.2 0.5 7.2 4.6 5.9 0.5 7.2 4.2 6.1 0.6 7.2 4.6 194 4 190 165 5.4 0 5.7 5 10/29/2006 00:40:00 5.5 0.5 6.5 4.2 5.3 0.4 6.1 4.2 5.5 0.5 6.8 4.2 190 4 194 165 5.4 0 5.7 5 10/29/2006 00:50:00 4.4 0.7 5.7 2.3 4.5 0.7 6.1 2.3 4.5 0.7 6.1 2.6 192 8 201 165 5.4 0 5.7 5 10/29/2006 01:00:00 5 0.7 6.5 3.4 5 0.7 6.8 3.4 5 0.7 6.8 3.4 198 8 204 165 5.5 0.1 6 5 10/29/2006 01:10:00 4.7 0.5 6.1 3 4.8 0.5 5.7 3.4 4.7 0.5 6.1 3.4 198 7 193 165 5.5 0.1 5.7 5 10/29/2006 01:20:00 5.4 0.7 6.8 3 5.3 0.6 6.5 3.4 5.6 0.7 6.8 3.8 187 5 184 165 5.7 0.1 6 5.2 10/29/2006 01:30:00 5.1 0.4 6.1 4.2 5 0.4 5.7 4.2 5.3 0.4 6.5 4.2 185 5 173 165 5.6 0.1 6 5.2 10/29/2006 01:40:00 5.1 0.6 6.8 3.4 5.1 0.5 6.5 3.8 5.2 0.6 6.5 3.4 189 7 180 165 5.6 0 5.7 5.2 10/29/2006 01:50:00 5.2 0.4 6.1 4.2 5.2 0.4 6.1 3.8 5.4 0.5 6.5 4.2 196 5 190 165 5.6 0.1 6 5 10/29/2006 02:00:00 5.3 0.8 7.6 4.2 5.4 0.8 7.6 4.2 5.6 0.7 7.6 4.6 199 4 199 165 5.7 0.1 6 5.5 10/29/2006 02:10:00 5.9 0.5 6.8 4.2 5.7 0.5 6.8 4.2 6.1 0.6 7.6 4.6 200 7 192 165 5.7 0.1 6 5.5 10/29/2006 02:20:00 5.5 0.5 6.8 4.2 5.4 0.5 6.5 4.2 5.7 0.6 7.2 3.8 203 6 203 165 5.7 0.1 6 5.2 10/29/2006 02:30:00 6.4 1 8.4 3.8 6.3 1 8.4 3.8 6.3 1 8.4 3.8 213 6 211 165 5.7 0.1 6 5.2 10/29/2006 02:40:00 4.8 0.6 6.5 3.4 4.9 0.6 6.5 3.8 4.9 0.6 6.5 3.4 209 7 196 165 5.6 0.2 6 4.8 10/29/2006 02:50:00 4.8 0.5 6.5 3.8 4.9 0.5 6.5 3.8 4.8 0.5 6.5 3.8 208 5 207 165 5.6 0.1 6 5.2 10/29/2006 03:00:00 5.4 0.7 6.5 3.8 5.3 0.6 6.5 3.8 5.3 0.7 6.8 3.4 190 8 192 165 5.9 0.2 6.2 5 10/29/2006 03:10:00 5.9 0.9 7.6 3.8 5.8 0.9 8 3.8 5.8 1 8 3.4 196 7 203 165 5.6 0.1 6 5 10/29/2006 03:20:00 5.7 0.7 7.2 3.8 5.6 0.7 7.2 3.8 5.8 0.9 7.2 2.6 199 7 197 165 5.7 0.2 6.2 5.2 10/29/2006 03:30:00 5.7 0.5 6.8 4.6 5.7 0.5 6.8 4.2 5.8 0.6 6.8 3.8 214 4 215 165 5.9 0 6.2 5.2 10/29/2006 03:40:00 5.5 0.5 6.8 4.6 5.5 0.5 6.8 4.6 5.8 0.5 7.6 4.6 206 6 202 165 6.1 0.1 6.2 5.5 10/29/2006 03:50:00 5.9 0.9 7.6 3.8 5.7 0.8 7.6 3.8 6.1 0.9 8 3.8 194 7 191 165 5.9 0.1 6.2 5.5 10/29/2006 04:00:00 6 0.6 8 4.9 5.7 0.6 7.6 4.6 6.3 0.7 8 4.6 195 5 193 165 5.5 0 5.7 5.2 10/29/2006 04:10:00 6.1 0.5 7.6 4.6 6 0.6 7.6 4.6 6.2 0.6 7.6 4.2 206 5 213 165 5.6 0 5.7 5.5 10/29/2006 04:20:00 7.2 1.1 9.9 4.6 7.2 1.1 10.3 4.6 7.3 1.2 11.5 4.2 216 7 216 165 5.8 0.1 6 5.5 10/29/2006 04:30:00 7 1.1 9.1 3 7 1.1 9.1 3.4 6.9 1.1 9.1 3.8 214 6 213 165 5.8 0 6 5.7 10/29/2006 04:40:00 6.6 0.9 8.8 4.6 6.6 0.9 8.8 4.6 6.5 0.9 8.8 4.6 215 6 221 165 5.7 0.1 6.2 5.5 10/29/2006 04:50:00 6.3 0.7 8.4 4.2 6.3 0.7 8.4 4.2 6.2 0.7 8 3.8 211 6 213 165 5.6 0 5.7 5.2 10/29/2006 05:00:00 5.7 0.6 7.6 3.4 5.6 0.6 7.6 3.8 5.4 0.6 7.2 3.8 211 7 208 165 5.6 0 6.2 5.2 10/29/2006 05:10:00 4.8 0.6 6.5 3.4 4.8 0.6 6.5 3.8 4.6 0.6 6.1 2.6 207 8 212 165 5.5 0 5.7 5 10/29/2006 05:20:00 6.2 1 8 3.4 6.3 1 8 3.8 6.1 1 8.8 4.2 200 6 199 165 5.6 0 5.7 5 10/29/2006 05:30:00 6 0.9 8.4 4.2 5.8 0.9 8.4 4.2 6.1 1 8.8 3.8 193 8 198 165 5.6 0 6 5 10/29/2006 05:40:00 6 0.8 8 3.8 5.8 0.8 7.6 3.8 5.8 0.9 7.6 3.8 198 6 191 165 5.6 0 6 5 10/29/2006 05:50:00 5.2 0.9 7.2 2.6 5.1 0.8 6.8 2.6 4.9 0.9 6.8 2.6 197 7 200 165 5.4 0 5.7 5 10/29/2006 06:00:00 4.5 1 6.8 2.3 4.6 1 6.8 2.3 4.4 0.9 6.8 2.3 197 10 206 165 5.4 0 6 5 10/29/2006 06:10:00 6.5 0.5 8 5.3 6.7 0.5 8 5.3 6.6 0.6 8 4.6 207 4 208 165 5.6 0 5.7 5.5 10/29/2006 06:20:00 6.6 0.7 8.8 4.9 6.6 0.7 8.8 4.9 6.7 0.8 8.4 4.6 203 5 205 165 5.6 0 6 5.5 10/29/2006 06:30:00 5.6 0.6 6.8 3.8 5.6 0.6 7.2 3.8 5.7 0.8 7.6 3.8 198 4 199 165 5.4 0 5.7 5.2 10/29/2006 06:40:00 6 0.6 7.6 4.6 6.1 0.7 7.6 4.6 6.3 0.8 8 4.6 198 5 196 165 5.4 0 5.7 5.2 10/29/2006 06:50:00 5.4 0.4 6.5 4.2 5.2 0.4 6.1 4.2 5.7 0.4 6.8 4.6 194 6 203 165 5.5 0 5.7 5.5 10/29/2006 07:00:00 5.4 0.6 6.8 3.8 5.2 0.6 6.8 3.4 5.5 0.6 7.6 4.2 187 7 185 165 5.5 0 6 5.5 10/29/2006 07:10:00 6.1 0.6 7.6 4.6 6.1 0.5 7.6 4.6 6.2 0.6 8 4.9 187 4 188 165 5.4 0 5.7 5.2 10/29/2006 07:20:00 5.7 0.5 6.8 4.6 5.7 0.4 6.8 4.9 6 0.5 7.2 4.9 189 3 194 165 5.4 0 5.7 5.2 10/29/2006 07:30:00 5.8 0.5 6.8 4.9 5.8 0.5 6.8 4.9 6 0.5 7.2 4.9 188 5 193 165 5.5 0 5.7 5.5 10/29/2006 07:40:00 5.7 1 8 3.4 5.6 0.9 7.6 3.8 5.7 1 8 3.8 183 8 183 165 5.6 0 5.7 5.5 10/29/2006 07:50:00 4.8 0.5 5.7 3 4.7 0.5 6.1 3.4 4.7 0.5 5.7 3.4 186 8 182 165 5.6 0 5.7 5.5 10/29/2006 08:00:00 3.4 0.7 5.3 1.5 3.4 0.6 5.3 1.9 3.6 0.6 4.9 2.3 178 12 173 165 5.7 0 6 5.5 10/29/2006 08:10:00 3.2 0.5 4.9 1.5 3.2 0.5 4.9 1.9 3.2 0.6 4.9 1.9 170 9 165 165 5.7 0.1 6 5.5 10/29/2006 08:20:00 3.8 0.5 5.3 2.3 3.8 0.5 4.9 2.3 4 0.5 5.3 2.3 159 9 158 165 5.6 0.1 6 5.5 10/29/2006 08:30:00 3.5 0.6 4.9 1.9 3.4 0.6 4.9 1.9 3.7 0.6 5.7 2.3 161 10 187 165 6 0 6.2 5.5 10/29/2006 08:40:00 2.9 0.8 4.2 0.7 2.8 0.8 3.8 0.7 3.1 0.8 4.6 0.7 169 13 177 165 6.5 0.2 7 5.7 10/29/2006 08:50:00 2.3 0.5 3.4 1.1 2.2 0.4 3.4 0.7 2.7 0.3 3.4 1.9 168 6 171 165 7.1 0.2 7.5 6.5 10/29/2006 09:00:00 2.6 0.5 3.8 1.1 2.4 0.5 3.8 0.7 2.7 0.5 3.8 1.1 183 10 182 165 7.5 0.1 8 7 10/29/2006 09:10:00 2.9 0.5 4.2 1.9 2.7 0.5 3.8 1.5 2.9 0.4 4.2 1.9 188 9 195 165 8 0.1 8.5 7.5 10/29/2006 09:20:00 2.1 0.5 3.8 0.4 2 0.6 3.4 0.4 2.4 0.4 3.4 0.7 184 13 185 165 8.7 0.2 9 8 10/29/2006 09:30:00 2.6 0.5 3.8 1.1 2.6 0.5 3.8 0.7 3.1 0.5 4.6 1.9 165 9 176 165 9.1 0 9.3 9 10/29/2006 09:40:00 2 0.6 3.4 0.4 1.9 0.6 3.4 0.4 2.3 0.6 3.8 0.7 174 16 150 165 9.3 0.1 9.6 9 10/29/2006 09:50:00 2.4 0.6 4.6 0.4 2.4 0.7 4.2 0.4 2.8 0.7 4.6 0.4 173 18 165 165 9.6 0 9.8 9.3 10/29/2006 10:00:00 1.6 0.6 3.4 0.4 1.6 0.7 3.4 0.4 2.1 0.6 3.8 0.7 192 22 196 165 9.6 0.1 9.8 9.3 10/29/2006 10:10:00 2.1 0.6 3.4 0.4 1.8 0.6 3.4 0.4 2.3 0.6 3.8 0.4 221 15 201 165 9.8 0 10.6 9.6 10/29/2006 10:20:00 1.7 0.5 2.6 0.7 1.3 0.6 2.6 0.4 1.9 0.5 3.4 0.7 231 17 203 165 10.1 0 10.6 9.8 10/29/2006 10:30:00 1.4 0.7 3.4 0.4 1.1 0.8 3.4 0.4 1.6 0.6 3.8 0.4 234 26 234 165 10.3 0.2 10.9 9.8 10/29/2006 10:40:00 2.2 0.8 4.2 0.7 2.2 0.8 4.2 0.4 2.1 0.6 3.8 0.7 273 17 295 165 10.6 0.1 10.9 10.1 10/29/2006 10:50:00 4.9 1.2 8 3 5 1.3 8 3 3.9 1 6.5 2.3 301 6 295 165 8.7 0.6 10.1 7.5 10/29/2006 11:00:00 5.7 0.8 7.6 4.2 5.8 0.8 7.6 4.2 4.7 0.8 6.5 3 306 4 302 165 7.3 0 7.8 7.3 10/29/2006 11:10:00 5.1 0.6 6.8 3.4 5.2 0.7 6.8 3 4 0.5 5.7 2.6 302 5 304 165 8.1 0.2 8.8 7.5 10/29/2006 11:20:00 4.1 0.8 5.7 2.3 4.1 0.8 5.7 1.9 3.4 0.7 4.9 1.5 306 8 304 165 8.8 0.3 9.6 8.3 10/29/2006 11:30:00 3.5 0.9 6.1 1.5 3.5 0.9 6.1 1.5 2.7 0.9 5.3 0.7 299 17 298 165 9.6 0.1 10.1 9 10/29/2006 11:40:00 4.6 0.8 6.8 1.5 4.6 0.9 7.2 1.9 3.9 1 6.5 1.9 297 15 274 165 8.1 0.4 9 7.5 10/29/2006 11:50:00 5.1 0.7 6.8 3 5.3 0.8 6.8 3 4.6 0.8 6.5 2.3 295 13 312 165 7.5 0 7.8 7.5 10/29/2006 12:00:00 4.7 0.7 6.5 3 4.7 0.7 7.2 3 4.3 0.6 6.1 3 314 9 301 165 7.7 0 8.3 7.5 10/29/2006 12:10:00 4.5 0.8 6.8 3 4.5 0.8 6.8 3 3.7 0.8 6.1 1.9 303 9 305 165 7.8 0 8.3 7.5 10/29/2006 12:20:00 5 0.6 6.5 3.8 5.1 0.6 6.8 3.8 4.1 0.7 6.1 2.6 299 8 302 165 8 0.1 8.3 7.5 10/29/2006 12:30:00 6.8 1 9.1 4.2 6.9 1 9.1 4.2 5.7 1 8.4 3 302 7 307 165 7.5 0 8 7.3 10/29/2006 12:40:00 7.2 0.7 9.5 5.3 7.2 0.7 9.5 4.9 6.4 0.8 8.4 4.6 309 5 298 165 7.8 0 8 7.5 10/29/2006 12:50:00 8.9 0.9 10.7 6.8 8.9 0.9 11.1 6.8 7 1 9.5 4.6 304 4 301 165 7.3 0.2 7.8 7 10/29/2006 13:00:00 8.6 1.1 11.1 5.7 8.5 1.1 11.5 5.7 7.1 1 10.3 4.9 303 6 305 165 7.1 0.2 7.8 6.7 10/29/2006 13:10:00 9.5 1.1 11.8 5.7 9.5 1.2 11.8 6.1 7.6 1 11.1 4.9 304 6 298 165 6.6 0.1 7.3 6.2 10/29/2006 13:20:00 9.5 1.1 12.2 6.8 9.5 1.1 12.6 6.8 8.1 1.1 11.1 5.7 307 7 301 165 6.4 0 6.7 6.2 10/29/2006 13:30:00 9 1 11.5 5.7 8.9 1 11.5 5.7 8.4 1.2 11.5 4.9 313 7 315 165 6.9 0.1 7.5 6.5 10/29/2006 13:40:00 7.5 1.5 10.7 4.6 7.5 1.3 10.7 4.6 7.5 1.5 11.1 3.8 314 8 321 165 7.3 0.1 7.8 7 10/29/2006 13:50:00 6.7 1.6 11.1 3.4 6.8 1.5 11.1 3.8 6.1 1.5 10.7 3 307 10 310 165 7.5 0.1 8.3 7.3 10/29/2006 14:00:00 6.9 1 9.5 4.2 6.9 1 9.1 4.2 6.3 1.2 9.5 3.8 303 12 314 165 7.3 0 7.8 7 10/29/2006 14:10:00 7.4 1 11.1 5.3 7.4 1 10.7 5.3 6.8 1.1 9.5 4.2 307 8 302 165 7.3 0 7.8 7.3 10/29/2006 14:20:00 7.8 1 10.7 5.7 7.9 1 10.7 5.7 6.9 1 10.3 4.6 305 7 314 165 7.3 0 7.8 7 10/29/2006 14:30:00 7.7 1 10.3 4.9 7.7 1 10.3 4.9 7.1 1.1 9.9 4.2 309 7 307 165 7.4 0.1 7.5 7.3 10/29/2006 14:40:00 6.5 0.9 9.1 4.2 6.5 0.9 8.8 4.6 5.9 1 8.8 3.8 304 7 313 165 7.5 0 7.8 7.3 10/29/2006 14:50:00 6.9 0.7 8.8 4.9 7 0.7 8.8 5.3 6 0.9 8 3.8 297 7 311 165 7.4 0 7.5 7.3 10/29/2006 15:00:00 7 0.9 9.1 4.9 7.1 0.9 9.1 4.9 5.8 0.8 8.4 3.8 300 6 302 165 7.3 0 7.5 7 10/29/2006 15:10:00 7.4 0.9 9.5 4.9 7.5 0.9 9.5 5.3 6.1 1 8.4 3.4 296 7 295 165 7.3 0 7.8 7 10/29/2006 15:20:00 8.4 0.8 10.3 6.8 8.5 0.8 10.3 6.8 6.8 0.7 9.1 4.9 301 5 300 165 7.1 0 7.5 6.7 10/29/2006 15:30:00 7.1 0.8 9.1 4.6 7.2 0.8 9.1 4.9 6.1 0.9 8 3.8 301 7 298 165 7.1 0 7.3 7 10/29/2006 15:40:00 6.7 0.8 8.4 4.6 6.8 0.8 8.4 4.9 5.6 0.9 8 3.8 302 6 312 165 6.9 0.1 7.3 6.7 10/29/2006 15:50:00 6.9 0.7 9.1 5.3 7 0.7 9.1 4.9 5.6 0.7 7.6 4.2 301 5 302 165 6.5 0.1 7 6.2 10/29/2006 16:00:00 8.1 1 10.3 5.7 8.1 1 10.3 5.7 6.9 0.8 8.8 4.6 307 6 304 165 6.5 0 6.7 6.2 10/29/2006 16:10:00 7.1 0.8 9.1 4.9 7.2 0.8 9.5 4.6 5.9 1 8.8 4.2 301 6 306 165 6.4 0 6.7 6.2 10/29/2006 16:20:00 7.7 0.8 9.9 5.7 7.9 0.8 9.9 5.7 6.3 0.8 8.8 4.6 298 5 297 165 6.3 0 6.7 6.2 10/29/2006 16:30:00 6.9 1.2 9.9 4.6 7.1 1.2 9.9 4.9 5.5 1 8.8 3.4 299 5 294 165 6 0.2 6.2 5.5 10/29/2006 16:40:00 5 0.4 6.1 3.8 5.2 0.4 6.1 4.2 4.5 0.6 6.1 3 286 7 289 165 5.5 0 5.7 5.2 10/29/2006 16:50:00 5.1 0.9 7.6 3 5.3 1 7.6 3.4 4.6 0.8 7.6 2.6 287 6 285 165 5.4 0 5.7 5.2 10/29/2006 17:00:00 6 0.8 8.4 4.6 6.2 0.8 8.4 4.6 5.6 0.8 8 3.4 284 6 302 165 5.7 0 6 5.5 10/29/2006 17:10:00 5.5 0.9 7.6 3 5.7 0.9 8 3 5.4 1 7.6 3 282 7 279 165 5.7 0 6 5.5 10/29/2006 17:20:00 5.6 0.5 7.2 4.2 5.8 0.5 7.2 4.6 5.4 0.7 7.2 3.4 285 6 291 165 5.6 0 6 5.5 10/29/2006 17:30:00 5.4 0.6 7.2 3.8 5.5 0.6 6.8 4.2 5.3 0.6 7.2 3.4 281 6 288 165 5.6 0 6 5.5 10/29/2006 17:40:00 5.4 0.6 6.8 3.8 5.5 0.6 6.8 4.2 5 0.6 6.8 3.4 283 6 279 165 5.4 0 5.7 5 10/29/2006 17:50:00 5 0.5 6.1 3 5.1 0.5 6.1 3 4.1 0.6 5.7 2.6 293 6 291 165 5.6 0.1 6 5.2 10/29/2006 18:00:00 5.1 0.6 6.8 3.4 5.2 0.6 6.8 3.8 4.1 0.6 6.1 2.6 300 7 304 165 5.6 0 5.7 5.2 10/29/2006 18:10:00 4.9 0.5 6.5 3.4 5 0.5 6.8 3.4 4 0.6 6.1 2.6 297 8 292 165 5.6 0.2 6 5 10/29/2006 18:20:00 3.6 0.5 4.6 2.3 3.7 0.5 4.9 2.3 3.1 0.5 4.6 1.9 290 7 288 165 5.6 0.2 6 5 10/29/2006 18:30:00 3.3 0.6 5.3 2.3 3.4 0.6 5.3 2.3 3.3 0.7 5.3 1.5 295 14 302 165 5.5 0 6.2 5 10/29/2006 18:40:00 3.6 0.4 4.9 2.3 3.7 0.4 4.9 2.3 3.1 0.6 4.6 1.9 299 7 293 165 5.4 0 5.7 4.8 10/29/2006 18:50:00 4.4 0.5 6.1 3.4 4.4 0.6 6.1 3.4 3.7 0.5 5.3 2.6 303 6 298 165 5.2 0.1 5.5 4.5 10/29/2006 19:00:00 5.9 0.5 6.8 4.6 6 0.5 7.2 4.9 5.2 1 7.2 3.4 305 7 312 165 5.1 0 5.2 4.8 10/29/2006 19:10:00 6.4 0.4 7.6 5.7 6.5 0.4 7.6 5.7 5.7 0.9 8 3.8 300 9 290 165 4.8 0.1 5.2 4.8 10/29/2006 19:20:00 6.4 0.5 7.6 5.3 6.6 0.5 7.6 5.3 5.3 0.6 6.8 3.8 292 3 292 165 4.9 0 5 4.8 10/29/2006 19:30:00 6.4 0.4 7.6 5.3 6.5 0.4 7.6 5.3 4.9 0.6 6.5 3.4 296 3 297 165 5.1 0 5.2 4.8 10/29/2006 19:40:00 6.7 0.6 8.4 5.3 6.9 0.6 8.4 5.3 6.3 1 8.4 4.2 288 4 287 165 5.2 0 5.5 5 10/29/2006 19:50:00 6.1 0.6 7.6 4.9 6.3 0.6 7.6 4.9 5.8 0.9 8 3.4 291 3 288 165 5.1 0 5.2 4.8 10/29/2006 20:00:00 5.3 0.6 6.5 3.8 5.4 0.6 6.8 4.2 4.7 0.8 6.8 3 294 6 285 165 5.1 0 5.5 5 10/29/2006 20:10:00 4.7 0.4 5.7 3.8 4.9 0.4 5.7 3.8 4.5 0.6 6.1 3 290 8 299 165 5.1 0 5.5 4.8 10/29/2006 20:20:00 4.9 0.5 6.5 3.4 5.1 0.5 6.5 3.8 4.6 0.9 6.5 2.6 287 4 281 165 5 0.1 5.5 4.8 10/29/2006 20:30:00 4.5 0.4 5.7 3.8 4.6 0.4 5.7 3.8 4.1 0.5 5.7 3 290 3 291 165 4.8 0.1 5.5 4.5 10/29/2006 20:40:00 5.2 0.3 6.1 4.2 5.4 0.3 6.1 4.6 4.3 0.5 5.7 3.4 293 3 293 165 4.6 0.1 5 4.3 10/29/2006 20:50:00 4.7 0.6 5.7 2.6 4.9 0.5 6.1 3 4.2 0.5 5.3 2.6 285 6 287 165 4.6 0.1 5 4.3 10/29/2006 21:00:00 5 0.5 6.5 3.4 5.2 0.5 6.5 3.8 4.8 0.6 6.1 2.6 283 5 283 165 4.8 0 5.2 4.5 10/29/2006 21:10:00 5.1 0.5 6.1 3.8 5.3 0.5 6.5 4.2 5.1 0.6 6.5 3 282 3 277 165 4.9 0 5 4.8 10/29/2006 21:20:00 4.5 0.5 5.7 3 4.7 0.5 6.1 3.4 4.6 0.5 6.1 3.4 278 4 286 165 4.8 0 5 4.5 10/29/2006 21:30:00 2.8 0.7 4.6 1.5 3 0.9 4.9 0.7 2.6 0.7 4.9 1.1 308 27 281 165 4.7 0.2 5 4.3 10/29/2006 21:40:00 2.7 0.6 4.6 1.1 2.7 0.6 4.6 1.1 3 0.6 4.6 1.5 337 24 330 165 4.6 0 4.8 4 10/29/2006 21:50:00 1.9 0.8 3.8 0.4 2.1 0.8 3.8 0.4 2 0.5 3 0.4 308 18 318 165 4.8 0.1 5.2 4.5 10/29/2006 22:00:00 1.4 0.6 3 0.4 1.4 0.7 3.4 0.4 2.1 0.6 3.4 0.7 342 17 336 165 4.9 0 5.5 4.3 10/29/2006 22:10:00 2.1 0.6 3.8 0.7 2 0.7 3.8 0.4 2.5 0.5 4.6 1.1 333 17 324 165 4.6 0.1 5 4.3 10/29/2006 22:20:00 2.6 0.5 3.8 1.5 2.8 0.5 4.2 1.1 3.1 0.5 4.6 1.5 327 13 332 165 4.6 0 5 4.3 10/29/2006 22:30:00 2.9 0.8 4.6 1.5 3.1 0.8 4.6 1.5 2.6 0.6 4.6 1.1 304 8 301 165 4.7 0 5 4.5 10/29/2006 22:40:00 5 0.7 6.5 3.4 5.1 0.7 6.8 3.8 4 0.6 6.1 2.6 299 6 297 165 4.8 0 5 4.5 10/29/2006 22:50:00 4.6 0.3 5.3 3.8 4.8 0.3 5.7 3.8 3.8 0.5 5.3 2.6 297 4 296 165 4.7 0.1 5.2 4.5 10/29/2006 23:00:00 4.8 0.4 5.7 3.8 5 0.4 5.7 3.8 3.9 0.6 5.3 2.6 302 4 300 165 4.6 0 5.2 4.5 10/29/2006 23:10:00 5.2 0.4 6.1 4.2 5.3 0.4 6.1 4.2 4.2 0.5 6.1 3 293 4 300 165 4.5 0 4.8 4.3 10/29/2006 23:20:00 5 0.4 5.7 3.8 5.2 0.3 6.1 4.2 4.2 0.5 5.3 3 292 3 294 165 4.4 0 4.8 4.3 10/29/2006 23:30:00 5.3 0.4 6.1 4.6 5.5 0.4 6.5 4.6 5 0.6 6.5 3.4 285 3 289 165 4.4 0 5 4 10/29/2006 23:40:00 5.1 0.3 5.7 3.4 5.3 0.3 5.7 3.8 5.1 0.5 6.1 3.8 281 3 283 165 4.4 0 4.8 4.3 10/29/2006 23:50:00 4.1 0.5 4.9 2.6 4.2 0.6 5.3 2.3 4 0.6 5.3 2.3 282 4 282 165 4.4 0 4.8 4 10/30/2006 00:00:00 4 0.4 4.9 3 4.1 0.4 4.9 3.4 3.3 0.5 4.6 2.3 291 6 294 165 4.4 0 4.8 4 10/30/2006 00:10:00 4.2 0.4 5.3 3 4.2 0.4 5.3 3 3.2 0.4 4.2 2.3 301 4 300 165 4.2 0.1 4.5 3.8 10/30/2006 00:20:00 5.1 0.5 6.5 3.8 5.1 0.5 6.5 3.8 4.1 0.6 5.7 2.6 304 4 302 165 4.1 0 4.5 3.8 10/30/2006 00:30:00 4.2 0.6 5.3 3 4.2 0.6 5.3 3 3.9 0.6 4.9 2.6 310 4 309 165 4.3 0 4.5 3.8 10/30/2006 00:40:00 3.5 0.4 4.6 2.3 3.6 0.5 4.6 2.3 3 0.7 4.6 1.5 292 5 294 165 4.3 0 4.5 3.8 10/30/2006 00:50:00 3.9 0.4 4.9 3 4 0.4 5.3 3 3.1 0.4 4.2 2.3 297 4 287 165 4.3 0 4.8 3.8 10/30/2006 01:00:00 3.3 0.3 3.8 2.6 3.3 0.3 4.2 2.6 2.8 0.3 3.4 1.9 297 6 300 165 4.3 0 4.8 3.8 10/30/2006 01:10:00 3 0.4 3.8 1.9 3.1 0.4 3.8 1.9 2.8 0.5 3.8 1.9 300 9 295 165 4.4 0 4.8 4 10/30/2006 01:20:00 1.7 0.7 3.8 0.4 1.7 0.7 3.8 0.4 1.7 0.6 3.8 0.7 296 12 313 165 4.4 0 4.8 3.8 10/30/2006 01:30:00 2.6 0.6 3.8 1.1 2.8 0.6 3.8 1.1 2.3 0.5 3.8 1.1 291 8 295 165 4.5 0 4.8 3.8 10/30/2006 01:40:00 3.9 0.5 4.9 2.6 4 0.5 4.9 2.6 3.1 0.5 4.6 2.3 301 4 298 165 4.4 0 4.8 3.8 10/30/2006 01:50:00 4.4 0.4 4.9 3.4 4.5 0.4 5.3 3.8 3.6 0.6 4.9 2.3 292 3 294 165 4.3 0 4.5 4.3 10/30/2006 02:00:00 4.5 0.4 5.3 3 4.7 0.5 5.7 3 3.4 0.5 4.6 2.3 293 3 292 165 4.4 0 4.8 4.3 10/30/2006 02:10:00 4.4 0.5 5.7 2.6 4.5 0.6 5.7 2.6 3.6 0.4 4.9 2.3 299 6 291 165 4.4 0 4.8 4.3 10/30/2006 02:20:00 3.8 0.6 5.3 2.3 3.8 0.6 5.3 2.3 3.5 0.5 4.6 1.9 309 9 293 165 4.2 0.1 4.8 4 10/30/2006 02:30:00 2.9 0.5 4.2 1.5 2.9 0.5 4.2 1.9 3.1 0.5 4.2 1.9 315 8 315 165 3.9 0 4.3 3.5 10/30/2006 02:40:00 2.5 0.8 4.6 1.1 2.6 0.8 4.6 1.1 2.6 0.7 4.2 1.1 309 9 325 165 3.9 0.2 4.3 3.5 10/30/2006 02:50:00 1.9 0.5 3.4 0.7 2 0.5 3.4 0.7 2.3 0.4 3.4 1.1 313 11 323 165 4.1 0 4.5 4 10/30/2006 03:00:00 1.4 0.6 4.2 0.4 1.4 0.7 4.2 0.4 1.7 0.5 3 0.4 317 24 302 165 4.2 0 4.5 4.3 10/30/2006 03:10:00 1.7 0.6 3.4 0.4 1.6 0.7 3.4 0.4 2.2 0.4 3.4 1.1 332 10 336 165 4.1 0.1 4.5 4 10/30/2006 03:20:00 0.9 0.5 2.6 0.4 0.9 0.5 2.3 0.4 1.5 0.4 2.6 0.7 320 11 350 165 4.1 0 4.5 4.3 10/30/2006 03:30:00 1.6 0.5 2.6 0.4 1.6 0.5 3 0.4 1.7 0.4 3 0.7 301 12 298 165 4.3 0 4.5 4.3 10/30/2006 03:40:00 1.1 0.4 2.3 0.4 1.2 0.4 2.3 0.4 1.7 0.3 2.6 0.7 306 12 319 165 4.3 0 4.5 4.3 10/30/2006 03:50:00 1.8 0.6 3 0.7 1.9 0.6 3 0.7 2.1 0.5 3.4 0.7 289 10 279 165 4.1 0 4.5 4 10/30/2006 04:00:00 2.5 0.5 4.2 1.5 2.6 0.5 4.2 1.5 2.4 0.5 3.4 1.5 300 8 302 165 4.1 0 4.5 3.8 10/30/2006 04:10:00 2.4 0.5 3.4 1.1 2.5 0.5 3.4 1.1 2.6 0.5 3.4 1.1 310 8 306 165 3.9 0 4.3 3.8 10/30/2006 04:20:00 0.7 0.5 2.3 0.4 0.7 0.5 2.6 0.4 1 0.6 2.6 0.4 300 10 310 165 3.6 0.1 4.3 3.5 10/30/2006 04:30:00 0.7 0.4 1.5 0.4 0.7 0.4 1.5 0.4 1.2 0.5 2.3 0.4 310 11 317 165 3.8 0 3.8 3.5 10/30/2006 04:40:00 1.7 0.7 3 0.4 1.8 0.7 3 0.4 1.8 0.5 2.6 0.7 293 9 296 165 3.8 0 4 3.5 10/30/2006 04:50:00 1.9 0.5 3.4 0.7 2.1 0.6 3.4 0.7 2.1 0.4 3.4 1.5 294 7 306 165 3.8 0 4 3.5 10/30/2006 05:00:00 3.1 0.5 4.2 1.9 3.2 0.4 4.2 1.9 2.7 0.5 3.8 1.5 303 6 295 165 3.8 0 4.3 3.5 10/30/2006 05:10:00 4.1 0.5 5.3 3 4.1 0.5 5.3 3 3.3 0.6 4.9 2.3 296 7 297 165 3.6 0.1 4 3.3 10/30/2006 05:20:00 3.8 0.6 4.9 2.6 3.9 0.6 5.3 2.6 3.8 0.6 5.3 2.3 285 8 292 165 3.4 0 3.8 3.3 10/30/2006 05:30:00 3.6 0.8 5.3 1.9 3.7 0.8 5.3 2.3 3.4 0.7 5.3 1.9 289 7 292 165 3.4 0 3.5 3.3 10/30/2006 05:40:00 4 0.4 4.9 3 4 0.4 5.3 3 3.7 0.6 4.9 2.3 294 11 282 165 3.5 0 3.8 3.3 10/30/2006 05:50:00 4.2 0.4 5.3 3.4 4.2 0.5 5.3 3.4 3.3 0.5 4.6 2.3 301 4 302 165 3.3 0.1 3.8 3 10/30/2006 06:00:00 5 0.6 6.8 3.8 5.1 0.6 6.5 3.8 4.4 0.5 6.1 3 292 5 295 165 3.1 0.1 3.5 3 10/30/2006 06:10:00 5.5 0.5 6.8 4.2 5.5 0.5 6.8 4.2 4.9 0.7 6.8 3.4 289 4 286 165 3 0 3.3 3 10/30/2006 06:20:00 5.9 0.4 7.2 4.6 6.1 0.4 7.6 4.6 5.6 0.6 7.6 4.2 290 4 286 165 3.1 0.1 3.5 2.8 10/30/2006 06:30:00 4.8 0.5 6.1 3.4 4.8 0.6 6.5 3.4 4.4 0.6 6.1 2.6 289 5 296 165 3 0 3.3 2.8 10/30/2006 06:40:00 6.1 0.7 8 4.2 6.1 0.7 8 4.6 5.5 0.7 7.6 3.4 285 5 285 165 2.9 0.1 3 2.6 10/30/2006 06:50:00 6 0.5 7.6 4.6 5.8 0.5 7.6 4.6 4.6 0.8 6.8 2.6 293 6 282 165 2.9 0 3.3 2.6 10/30/2006 07:00:00 5.9 1.2 8.8 1.5 5.9 1.2 8.8 1.5 4.8 1.3 8 0.7 297 11 302 165 2.7 0.1 3 2.6 10/30/2006 07:10:00 6.7 0.8 8.4 4.2 6.7 0.8 8.4 4.2 5.5 0.9 8.4 3.4 294 6 294 165 3 0 3.3 2.8 10/30/2006 07:20:00 7.5 1.2 10.3 4.9 7.5 1.1 10.3 5.3 6 1.1 9.5 3.8 296 8 291 165 3 0 3.5 2.8 10/30/2006 07:30:00 7.1 1.2 9.5 4.2 7.1 1.1 9.5 4.2 6 1.4 9.9 3 291 8 287 165 3 0 3.5 2.8 10/30/2006 07:40:00 9.3 1.2 13.3 6.8 9.2 1.2 13 6.8 7.9 1.3 11.5 4.9 290 6 287 165 3.2 0 3.5 3 10/30/2006 07:50:00 9.9 1.2 12.6 6.1 9.9 1.2 12.6 6.5 8.4 1.2 12.2 4.9 290 6 291 165 3.3 0 3.5 3.3 10/30/2006 08:00:00 11.1 1 13.3 8.8 11.1 1 13.3 8.4 9 1.3 12.2 6.1 292 5 283 165 3.3 0 3.5 3.3 10/30/2006 08:10:00 11.9 0.7 13.7 10.3 12 0.7 13.7 10.3 9.3 1.2 12.6 6.5 293 4 295 165 3.5 0 3.8 3.3 10/30/2006 08:20:00 11.5 0.6 13.3 9.9 11.6 0.6 13.3 9.5 9.2 1 12.2 6.5 293 4 292 165 3.5 0 3.8 3.3 10/30/2006 08:30:00 12.1 1.3 14.5 8 12.1 1.2 14.5 8 9.2 1.4 13.3 6.1 295 5 300 165 3.5 0.1 3.8 3.3 10/30/2006 08:40:00 11.2 0.8 13.3 9.1 11.1 0.8 13.3 8.8 8.6 0.9 11.1 6.5 298 4 299 165 3.5 0 3.8 3.3 10/30/2006 08:50:00 10.6 0.7 12.6 8 10.6 0.8 12.6 8 8 0.8 10.7 6.5 298 5 284 165 3.6 0 4 3.5 10/30/2006 09:00:00 9.6 0.8 11.1 7.6 9.5 0.8 11.1 7.6 7.5 0.9 10.3 4.9 297 5 298 165 4 0.1 4.3 3.8 10/30/2006 09:10:00 7.5 1 9.9 5.3 7.5 0.9 9.5 5.3 6.1 0.9 9.5 4.2 301 6 292 165 4.2 0 4.5 4.3 10/30/2006 09:20:00 6.2 1.1 9.5 3.8 6.2 1.1 9.1 3.8 4.9 1.2 8.8 2.3 298 7 291 165 4.7 0.2 5.2 4.3 10/30/2006 09:30:00 5 1 6.8 2.6 5 1 6.8 3 4.4 1.1 6.8 2.3 289 7 295 165 5.1 0.2 5.5 4.5 10/30/2006 09:40:00 4.2 1 6.8 1.5 4.4 0.9 6.8 2.3 3.8 0.9 5.7 1.9 282 6 281 165 5.2 0.2 5.7 4.8 10/30/2006 09:50:00 2 0.6 3.4 0.4 2.3 0.7 3.8 0.4 2.4 0.5 3.8 0.7 250 18 229 165 5.7 0.1 6 5.5 10/30/2006 10:00:00 1.3 0.8 3.4 0.4 1.3 1 4.2 0.4 1.8 0.7 3.8 0.4 210 39 213 165 6.1 0.2 6.7 5.7 10/30/2006 10:10:00 1.7 0.9 4.2 0.4 1.5 0.9 4.2 0.4 2.3 0.7 4.2 0.7 164 22 147 165 6.4 0 7 6.2 10/30/2006 10:20:00 2.2 0.7 3.8 0.4 1.9 0.8 4.2 0.4 2.5 0.6 4.6 1.1 152 13 165 165 6.1 0 6.2 5.7 10/30/2006 10:30:00 1.2 0.7 3 0.4 0.9 0.6 3 0.4 1.4 0.7 3 0.4 167 61 128 165 6.4 0.2 7 5.7 10/30/2006 10:40:00 4.2 1.7 8 1.1 4.4 1.8 8.4 0.7 4.1 1.7 8 0.4 277 20 285 165 6.1 0.4 7 5.7 10/30/2006 10:50:00 3.9 1 7.2 1.5 4.4 1 7.6 1.5 4.2 1 6.8 1.5 267 13 273 165 6.3 0.1 6.7 5.7 10/30/2006 11:00:00 5.7 1.2 8 2.3 6 1.1 8.4 3 5.4 1.4 8 2.6 285 9 290 165 6 0.2 6.5 5.5 10/30/2006 11:10:00 5.9 1.3 9.1 1.9 6.1 1.3 9.1 2.3 5.5 1.3 8.4 2.6 286 10 294 165 5.6 0 6 5.5 10/30/2006 11:20:00 5.3 1.2 10.3 2.3 5.6 1.3 10.7 1.9 4.9 1.3 7.6 1.9 290 13 287 165 6.1 0.2 6.5 5.5 10/30/2006 11:30:00 6.3 1.3 8.8 1.9 6.4 1.2 9.1 1.9 5.7 1.2 9.5 2.6 291 11 278 165 5.9 0 6.2 5.7 10/30/2006 11:40:00 6.1 1.3 9.1 2.6 6.2 1.3 9.5 2.6 5.1 1.3 8.8 2.3 291 11 284 165 6.2 0.1 6.7 5.7 10/30/2006 11:50:00 8 1.4 11.1 4.6 8.2 1.3 11.1 4.9 7.5 1.3 10.3 4.6 287 10 290 165 5.6 0 6 5.2 10/30/2006 12:00:00 6.6 1.3 9.5 3.8 6.8 1.3 9.5 3.8 6 1.7 9.1 3 289 10 282 165 5.7 0.1 6 5.5 10/30/2006 12:10:00 6.4 1.1 8.8 3.4 6.6 1.1 9.1 3.4 6.1 1.5 8.8 2.6 285 9 282 165 5.9 0 6.2 5.7 10/30/2006 12:20:00 8.8 1.1 11.1 6.1 9 1.1 11.5 6.1 8.4 1.2 11.1 5.7 280 5 281 165 5.6 0 6 5.5 10/30/2006 12:30:00 8.7 1.2 11.5 4.9 8.8 1.1 11.5 5.7 7.9 1.4 11.5 4.2 290 9 287 165 5.6 0 6 5.2 10/30/2006 12:40:00 7.4 1.1 10.3 4.9 7.5 1.1 10.3 4.9 6.6 1.3 11.1 3.8 291 8 285 165 5.8 0.1 6.2 5.5 10/30/2006 12:50:00 6.4 1.5 10.3 3.4 6.4 1.4 9.9 3 5.3 1.5 9.1 2.6 305 11 308 165 6.5 0.2 7 6 10/30/2006 13:00:00 10.3 1.9 13.3 4.9 10.2 1.9 13.3 4.9 9 1.9 12.6 4.6 310 7 302 165 6.4 0.2 7 6 10/30/2006 13:10:00 11 1.2 13.7 8.4 11 1.1 13.3 8.4 10.6 1.4 13.7 6.8 314 6 321 165 6.1 0 6.7 5.7 10/30/2006 13:20:00 8.1 1.3 11.1 4.2 8.1 1.3 11.5 4.2 7.3 1.6 10.3 3.4 309 6 307 165 6.1 0 6.7 5.7 10/30/2006 13:30:00 8.4 1.1 10.7 5.3 8.3 1 10.7 5.3 7.7 1.1 10.3 5.3 312 6 312 165 5.9 0.2 6.7 5.5 10/30/2006 13:40:00 6.8 0.8 8.8 4.6 6.8 0.8 8.8 4.6 6.1 1 8.4 3.8 307 7 297 165 5.5 0 6.2 5.2 10/30/2006 13:50:00 6.9 0.6 8.8 4.9 6.9 0.6 8.4 5.3 6.3 0.6 7.6 4.9 307 6 298 165 5.5 0.2 6 5.2 10/30/2006 14:00:00 7.4 0.9 9.9 5.3 7.4 0.9 9.9 5.3 6.7 0.9 8.8 4.9 308 6 311 165 5.7 0 6.2 5.5 10/30/2006 14:10:00 6.9 1.2 9.5 4.6 7 1.1 9.5 4.9 6.3 1.2 9.1 3.4 303 10 296 165 5.9 0.3 6.2 5.5 10/30/2006 14:20:00 8.1 1.7 11.1 4.2 8.1 1.7 11.1 4.6 6.8 1.2 9.1 3.4 301 9 299 165 5.3 0.1 5.7 5 10/30/2006 14:30:00 8 1.1 11.1 4.2 8 1.1 11.5 3.8 6.7 1 9.5 4.2 301 8 291 165 5.2 0 5.5 5 10/30/2006 14:40:00 6 1 9.1 4.2 6.2 1 9.5 4.2 5.2 1.1 9.5 3 299 10 296 165 5.2 0.2 6 5 10/30/2006 14:50:00 5.2 0.7 6.8 2.6 5.3 0.8 6.8 2.6 4.3 0.9 6.8 1.9 297 11 280 165 6.6 0.3 7.3 5.7 10/30/2006 15:00:00 5 1 7.6 1.5 5.1 1 7.2 2.3 4.2 1 6.8 2.3 301 11 322 165 6.4 0.3 7 5.7 10/30/2006 15:10:00 4 1 7.2 1.9 4.1 1 7.2 1.5 3.2 1 6.1 0.7 304 15 278 165 5.5 0.1 6 5.2 10/30/2006 15:20:00 3.8 0.9 6.1 1.9 3.9 1 6.1 1.9 3.1 1 6.1 0.4 304 19 288 165 5.4 0 5.7 5 10/30/2006 15:30:00 3.9 0.8 5.7 1.9 3.9 0.8 6.1 1.9 3.1 0.9 5.3 1.1 303 13 315 165 5.3 0 5.7 5 10/30/2006 15:40:00 5.2 0.9 7.6 3 5.2 0.9 7.6 3 4.3 1 7.2 2.6 297 11 304 165 5 0.3 5.7 4.8 10/30/2006 15:50:00 4.7 1.4 7.2 1.5 4.8 1.3 7.2 1.9 3.8 1.2 6.5 1.5 294 10 295 165 4.6 0 4.8 4.5 10/30/2006 16:00:00 2.4 0.8 4.6 0.7 2.6 0.8 4.6 0.7 2 0.8 4.2 0.4 289 13 291 165 4.6 0 4.8 4.5 10/30/2006 16:10:00 1.6 0.6 3.4 0.4 1.9 0.6 3.4 0.7 1.6 0.6 3 0.4 307 15 288 165 4.6 0 4.8 4.5 10/30/2006 16:20:00 2 1 4.6 0.4 2.2 1 4.6 0.4 1.8 0.8 3.8 0.4 314 17 300 165 5 0.4 5.7 4.3 10/30/2006 16:30:00 3.8 1.3 7.2 1.9 3.9 1.3 7.2 1.9 3.9 1.2 6.8 1.9 321 9 322 165 5.4 0.4 6.2 4.3 10/30/2006 16:40:00 6.2 0.8 7.6 4.6 6.3 0.8 8 4.2 6.3 0.8 7.6 4.6 326 8 329 165 4.2 0.3 4.8 3.5 10/30/2006 16:50:00 6.5 0.7 8.8 5.3 6.5 0.7 8.4 5.3 6.2 0.6 8 4.6 316 8 326 165 3.9 0 4.3 3.3 10/30/2006 17:00:00 6.9 0.9 8.4 4.9 6.8 0.9 8.8 4.9 6.2 0.8 8.8 4.6 309 6 293 165 3.8 0 4.3 3.3 10/30/2006 17:10:00 6.4 0.6 8 4.9 6.4 0.6 8 4.6 6 0.6 7.6 4.2 310 5 308 165 3.8 0.1 4.3 3.5 10/30/2006 17:20:00 5.4 0.6 7.2 3.4 5.6 0.6 7.2 3.8 5 0.9 8 2.6 310 6 299 165 3.5 0 3.8 3.3 10/30/2006 17:30:00 3.4 1.3 5.7 0.4 3.5 1.3 5.7 0.4 2.7 1 4.6 0.4 303 28 323 165 3 0.2 3.5 2.6 10/30/2006 17:40:00 4.4 1.2 6.5 1.1 4.4 1.2 6.5 1.1 3.1 1.1 6.1 0.4 300 12 297 165 3 0 3.3 2.6 10/30/2006 17:50:00 5.1 1.2 7.6 1.5 5.2 1.2 7.2 1.9 3.7 1.3 7.2 0.7 298 9 318 165 3.2 0 3.5 2.8 10/30/2006 18:00:00 2.6 1.2 6.1 0.4 2.7 1.2 6.1 0.4 2 1 4.6 0.4 295 28 310 165 3.4 0 4.3 2.8 10/30/2006 18:10:00 4 1.6 7.2 0.4 4.1 1.5 7.2 0.7 3 1.5 5.7 0.4 298 26 289 165 3.3 0 3.5 2.8 10/30/2006 18:20:00 5 0.8 6.8 2.6 5 0.8 7.2 2.6 4.2 0.8 6.1 2.3 306 8 301 165 3.1 0 3.5 2.8 10/30/2006 18:30:00 4.6 0.6 6.5 3 4.6 0.6 6.5 3.4 3.9 0.6 5.7 2.3 309 8 314 165 2.9 0.1 3.3 2.6 10/30/2006 18:40:00 4.7 0.7 7.2 2.6 4.8 0.7 7.2 3 4 0.8 6.5 2.3 309 9 297 165 2.7 0.1 3 2.3 10/30/2006 18:50:00 5.3 1.3 8.4 2.3 5.4 1.3 8.4 1.9 4.7 0.9 7.2 1.9 312 13 301 165 3 0.2 3.3 2.3 10/30/2006 19:00:00 4.2 0.5 5.3 2.6 4.2 0.6 5.7 1.9 4.2 0.5 5.7 2.6 328 12 350 165 2.9 0.2 3.3 2.3 10/30/2006 19:10:00 4.1 0.5 5.3 2.6 4.1 0.5 5.3 3 4 0.5 4.9 3 317 7 310 165 2.9 0.2 3.3 2.3 10/30/2006 19:20:00 3.1 0.5 4.2 1.5 3.3 0.5 4.6 2.3 2.9 0.6 4.2 1.5 308 11 300 165 2.7 0 3 2.3 10/30/2006 19:30:00 3.1 0.8 4.6 1.1 3.3 0.7 4.9 1.9 2.6 0.6 4.2 1.5 300 6 295 165 2.7 0 3 2.6 10/30/2006 19:40:00 2.3 0.4 3.8 1.1 2.6 0.4 3.8 1.1 2.3 0.5 3.4 1.1 317 14 301 165 2.7 0.1 3 2.6 10/30/2006 19:50:00 3.5 1.1 5.7 0.7 3.6 1 5.7 1.1 3.8 0.9 6.1 1.5 330 10 346 165 3.2 0.1 3.5 2.8 10/30/2006 20:00:00 4.4 0.4 5.7 3.4 4.4 0.4 5.3 3.4 4.5 0.4 6.1 3.4 326 5 319 165 3.5 0.1 3.8 2.8 10/30/2006 20:10:00 5.1 0.5 6.5 3.8 5.2 0.5 6.5 4.2 5.3 0.5 6.5 4.2 322 5 317 165 3.5 0.1 3.8 3 10/30/2006 20:20:00 5.9 0.5 7.2 4.6 6 0.5 7.2 4.6 6 0.5 7.2 4.6 320 5 309 165 3.3 0 3.5 2.8 10/30/2006 20:30:00 6.3 0.6 7.6 4.6 6.4 0.6 7.6 4.6 5.3 1 7.6 3.4 306 7 309 165 3.2 0 3.5 3 10/30/2006 20:40:00 6.3 0.5 7.6 4.6 6.5 0.6 7.6 4.9 4.8 0.5 6.5 3.8 303 4 303 165 3 0 3.3 2.8 10/30/2006 20:50:00 6.5 0.4 7.2 5.7 6.7 0.3 7.6 5.7 4.6 0.4 5.7 3.8 302 2 300 165 2.9 0 3.3 2.8 10/30/2006 21:00:00 5.3 0.5 6.1 4.2 5.6 0.5 6.8 4.2 4.1 0.5 5.3 3 299 4 307 165 3 0.1 3.5 2.8 10/30/2006 21:10:00 4.4 0.3 5.3 3.4 4.5 0.3 5.3 3.4 3.3 0.4 4.2 2.3 300 3 299 165 2.9 0 3.3 2.8 10/30/2006 21:20:00 4.2 0.4 4.9 3.4 4.3 0.4 5.3 3.4 3.2 0.4 4.2 2.3 296 3 300 165 2.9 0 3.3 2.8 10/30/2006 21:30:00 4.1 0.3 4.9 3.4 4.3 0.3 5.3 3.8 3.2 0.4 4.6 2.3 294 3 293 165 2.9 0 3.3 2.8 10/30/2006 21:40:00 4.9 0.3 5.3 4.2 5.1 0.3 5.7 4.2 4 0.4 4.9 2.6 292 2 292 165 2.9 0 3.3 2.8 10/30/2006 21:50:00 5 0.3 5.7 4.6 5.1 0.3 6.1 4.6 4 0.4 4.9 3 294 1 292 165 2.9 0 3.3 2.8 10/30/2006 22:00:00 5.2 0.4 6.5 4.2 5.3 0.4 6.5 4.6 3.8 0.4 4.9 3 298 3 299 165 3 0 3.3 2.8 10/30/2006 22:10:00 5.2 0.6 7.6 3.8 5.3 0.6 7.6 3.8 4.3 0.7 6.1 3 294 4 304 165 3 0 3.3 2.8 10/30/2006 22:20:00 5.6 0.8 8.4 3.8 5.7 0.8 8.4 3.8 4.5 0.9 7.2 2.6 301 7 309 165 3.2 0 3.5 3 10/30/2006 22:30:00 6.2 1.1 9.5 4.2 6.3 1 9.1 4.2 4.9 0.9 8.4 3.4 301 5 312 165 3.2 0 3.5 3 10/30/2006 22:40:00 6.9 0.8 8.8 5.3 6.9 0.8 8.8 5.3 5.6 0.8 7.6 3.8 305 5 307 165 3.1 0 3.5 3 10/30/2006 22:50:00 7 0.9 9.5 5.3 7.1 0.8 9.5 5.3 5.5 0.7 8 3.8 304 4 303 165 3.1 0 3.5 2.8 10/30/2006 23:00:00 6.8 0.7 9.1 5.3 7 0.6 8.8 5.7 5.4 0.6 7.6 3.8 303 4 297 165 3.1 0 3.5 2.8 10/30/2006 23:10:00 6.8 0.5 8.4 5.7 7 0.5 8.4 6.1 5.6 0.8 7.6 4.2 306 5 303 165 3 0 3.5 2.8 10/30/2006 23:20:00 5.9 0.7 7.6 4.2 6 0.7 7.6 4.2 4.8 0.8 7.2 2.6 305 4 305 165 3.1 0.1 3.5 2.8 10/30/2006 23:30:00 5.8 0.4 6.5 4.6 5.8 0.4 6.8 4.2 4.4 0.4 5.7 3 302 3 304 165 2.7 0 3 2.6 10/30/2006 23:40:00 5.4 0.4 6.5 4.6 5.4 0.4 6.5 4.6 4 0.5 5.7 3 299 3 296 165 2.7 0 3 2.6 10/30/2006 23:50:00 5 0.3 5.7 4.2 5.1 0.3 5.7 4.2 4.2 0.5 5.3 3 306 4 303 165 2.7 0 3 2.6 10/31/2006 00:00:00 5 0.3 5.7 4.2 5 0.3 5.7 4.2 4.8 0.4 5.7 3.4 314 4 310 165 2.9 0 3 2.8 10/31/2006 00:10:00 5.1 0.5 6.8 3.4 5.2 0.5 6.5 3.4 4.7 0.5 6.1 2.6 311 5 311 165 2.9 0 3 2.8 10/31/2006 00:20:00 5.3 0.5 6.5 4.2 5.4 0.5 6.5 4.2 4.6 0.8 6.5 3 308 5 310 165 2.9 0 3.3 2.6 10/31/2006 00:30:00 5.5 0.4 6.5 4.2 5.6 0.4 6.5 4.6 5.2 0.5 6.1 3.8 311 3 312 165 2.8 0 3 2.6 10/31/2006 00:40:00 4.8 0.6 6.1 3.8 4.9 0.6 6.5 3.4 4.6 0.7 6.5 3 311 5 309 165 2.7 0 2.8 2.6 10/31/2006 00:50:00 5 0.4 5.7 4.2 5 0.4 6.1 4.2 4 0.5 5.3 2.6 304 5 302 165 2.7 0 2.8 2.6 10/31/2006 01:00:00 5 0.4 5.7 4.2 5.1 0.4 6.1 4.2 4 0.5 5.3 3 305 2 310 165 2.7 0 2.8 2.6 10/31/2006 01:10:00 5.5 0.4 6.5 4.6 5.6 0.5 6.8 4.6 4.7 0.5 6.1 3 308 2 305 165 2.7 0 2.8 2.6 10/31/2006 01:20:00 5.6 0.5 6.8 3.8 5.7 0.5 6.8 4.2 5.2 0.4 6.5 4.2 313 4 312 165 2.7 0 2.8 2.6 10/31/2006 01:30:00 4.7 0.5 5.7 3.4 4.7 0.5 5.7 3.8 4.5 0.4 5.7 3 315 5 324 165 2.8 0 3 2.6 10/31/2006 01:40:00 4.5 0.5 6.1 3.4 4.6 0.5 6.1 3.4 3.7 0.5 5.3 2.6 302 6 295 165 2.8 0 3 2.6 10/31/2006 01:50:00 5.1 0.4 6.1 3.8 5.2 0.5 6.1 3.8 4.2 0.6 6.1 3 295 5 295 165 2.9 0 3 2.8 10/31/2006 02:00:00 5.7 0.7 7.2 3.8 5.9 0.7 7.6 4.2 4.6 0.6 6.5 3 302 5 305 165 2.7 0 3 2.6 10/31/2006 02:10:00 4.2 0.8 6.1 2.6 4.3 0.8 6.1 2.3 4 0.7 6.1 2.3 307 12 290 165 2.7 0 2.8 2.6 10/31/2006 02:20:00 3.5 0.7 4.9 1.5 3.6 0.7 4.9 1.9 3.1 0.7 4.9 1.5 299 10 282 165 2.5 0.1 2.8 2.3 10/31/2006 02:30:00 4.5 0.7 6.5 3 4.6 0.8 6.5 3 3.9 0.9 6.5 2.3 298 8 295 165 2.7 0 2.8 2.6 10/31/2006 02:40:00 4.1 0.4 5.3 3 4.2 0.4 5.3 3 3.4 0.5 5.3 2.3 299 5 300 165 2.7 0 3 2.6 10/31/2006 02:50:00 4.5 0.6 6.5 2.3 4.5 0.7 6.8 1.9 4.2 0.7 6.5 2.3 313 11 313 165 2.6 0 2.8 2.6 10/31/2006 03:00:00 4.5 0.8 7.6 2.6 4.5 0.8 7.6 2.6 3.7 0.7 6.5 1.9 303 9 311 165 2.5 0.1 2.8 2.3 10/31/2006 03:10:00 5.5 0.9 8 3.4 5.5 0.9 8.4 3.4 4.9 0.9 8 2.6 315 12 325 165 2.2 0 2.6 1.8 10/31/2006 03:20:00 5.5 1.1 8.4 3.4 5.6 1.1 8.4 3.4 4.6 1 7.2 2.3 308 12 307 165 2.5 0.1 2.8 2.3 10/31/2006 03:30:00 6.6 0.9 9.1 4.6 6.5 0.8 9.1 4.9 5.4 0.8 7.6 3.8 306 7 305 165 2.4 0 2.6 2.3 10/31/2006 03:40:00 5.5 1.4 10.3 2.6 5.4 1.4 10.3 2.6 4.6 1 8 2.6 309 9 311 165 2.1 0.1 2.6 1.8 10/31/2006 03:50:00 5.6 1.3 8.8 1.9 5.7 1.3 8.8 1.9 5.5 1.2 8 2.6 323 11 312 165 2.1 0.2 2.8 1.8 10/31/2006 04:00:00 5.4 0.8 8.8 3.8 5.5 0.7 8.8 3.8 5.4 0.6 8 3.8 322 9 309 165 2.4 0.1 2.8 2.3 10/31/2006 04:10:00 5.8 0.9 8 3.4 5.8 0.9 8 3.4 5.3 0.7 7.6 3.4 312 10 315 165 2.4 0.1 2.8 2.3 10/31/2006 04:20:00 5.2 0.9 8 2.6 5.2 0.9 8 2.6 4.9 0.8 6.8 2.3 317 10 301 165 2.6 0 2.8 2.3 10/31/2006 04:30:00 5 0.8 7.2 2.6 5 0.9 6.8 2.3 4.6 0.8 6.5 2.6 313 13 305 165 2.4 0 2.8 2.3 10/31/2006 04:40:00 4.6 0.6 6.1 2.6 4.6 0.6 6.1 3 4.5 0.6 6.1 2.6 321 10 314 165 2.6 0 2.8 2.6 10/31/2006 04:50:00 3.2 0.6 4.6 1.5 3.2 0.7 4.9 0.7 3.5 0.6 5.3 1.9 328 13 334 165 2.7 0 2.8 2.6 10/31/2006 05:00:00 3 0.8 4.9 0.7 3 0.7 4.9 1.1 3.2 0.6 4.9 0.7 329 11 338 165 2.6 0.1 2.8 2.3 10/31/2006 05:10:00 2.7 0.6 4.6 1.1 2.5 0.8 4.6 0.4 2.8 0.6 4.9 1.1 346 29 326 165 2.5 0 2.8 2.3 10/31/2006 05:20:00 3.7 0.8 5.3 1.9 3.4 1 5.3 1.1 4.1 0.7 5.7 2.3 15 21 21 165 2.4 0 2.8 2.3 10/31/2006 05:30:00 3.9 0.7 5.3 1.5 3.5 0.8 4.9 1.1 4.2 0.8 5.7 1.9 18 12 29 165 2.2 0 2.6 2.1 10/31/2006 05:40:00 3.4 0.7 4.9 1.5 3.1 0.8 4.9 1.1 3.9 0.6 5.3 2.6 356 18 18 165 2 0.1 2.3 1.8 10/31/2006 05:50:00 3 0.6 4.9 1.9 3.1 0.6 4.9 1.9 3.3 0.5 4.9 2.6 333 8 336 165 2 0.1 2.3 1.8 10/31/2006 06:00:00 2.4 0.5 3.8 1.5 2.5 0.5 3.8 1.1 2.4 0.4 3.4 1.5 313 16 302 165 2 0 2.3 1.8 10/31/2006 06:10:00 3.3 0.4 4.2 2.3 3.4 0.4 4.6 2.6 2.7 0.4 4.2 1.9 298 5 292 165 1.9 0 2.3 1.8 10/31/2006 06:20:00 3.3 0.4 4.2 2.3 3.4 0.4 4.2 2.6 3 0.4 4.2 2.3 309 8 321 165 2 0 2.3 1.8 10/31/2006 06:30:00 3.6 0.4 4.9 2.6 3.7 0.4 4.9 2.6 3.3 0.5 4.6 1.9 312 8 336 165 2.1 0 2.3 2.1 10/31/2006 06:40:00 4.6 0.7 6.5 3.4 4.6 0.7 6.5 2.6 4.6 0.6 6.5 3.4 333 11 334 165 2.1 0 2.3 1.8 10/31/2006 06:50:00 4 0.6 5.3 2.6 4.1 0.6 5.3 2.3 3.9 0.9 6.1 1.9 316 18 311 165 2.3 0.1 2.6 1.8 10/31/2006 07:00:00 3.1 0.7 4.9 1.9 3.2 0.7 4.9 1.9 3.1 0.5 4.6 1.9 314 9 306 165 2.1 0.1 2.6 1.8 10/31/2006 07:10:00 2.9 0.5 3.8 1.5 2.9 0.5 3.8 1.5 3 0.6 4.2 1.5 317 10 297 165 2.1 0 2.6 1.8 10/31/2006 07:20:00 2.9 0.8 4.9 0.7 2.9 0.8 4.9 0.7 3 0.7 4.9 1.5 321 17 329 165 2.3 0 2.6 2.1 10/31/2006 07:30:00 3.4 0.7 5.3 1.9 3.4 0.7 5.3 1.9 3.5 0.6 4.9 2.3 324 9 328 165 2.1 0 2.3 1.8 10/31/2006 07:40:00 2.8 0.7 4.6 1.1 2.5 0.7 4.6 1.1 3 0.6 4.6 1.5 340 17 344 165 2.1 0.1 2.6 1.8 10/31/2006 07:50:00 2.2 0.8 4.6 0.4 2.1 1 4.6 0.4 2.5 0.8 4.9 1.1 334 17 339 165 2.2 0 2.6 1.8 10/31/2006 08:00:00 3.7 1.1 7.2 1.5 3.6 1 6.5 1.5 3.8 1.2 6.8 1.5 323 22 356 165 2.1 0 2.6 1.8 10/31/2006 08:10:00 2.8 0.8 4.6 1.5 2.9 0.7 4.6 1.5 3 0.8 4.6 1.5 318 12 333 165 2.2 0 2.6 2.1 10/31/2006 08:20:00 3.2 0.5 4.6 1.5 3.2 0.5 4.6 1.5 3.4 0.5 4.6 2.3 324 9 315 165 1.9 0 2.3 1.6 10/31/2006 08:30:00 4.6 0.8 6.1 2.3 4.7 0.9 6.8 2.3 4.4 0.7 6.1 2.6 316 9 316 165 1.8 0.1 2.1 1.6 10/31/2006 08:40:00 4.8 0.5 6.5 3.8 4.8 0.5 6.8 3.4 4.6 0.5 6.1 3.4 317 7 311 165 2.1 0 2.3 1.8 10/31/2006 08:50:00 4.8 0.7 6.5 2.6 4.8 0.7 6.5 2.6 4.7 0.7 6.5 2.6 319 9 332 165 2.1 0 2.6 1.8 10/31/2006 09:00:00 4.6 0.7 6.5 2.6 4.5 0.7 6.1 2.6 4.6 0.6 6.1 3 324 11 357 165 2.6 0.1 3 2.3 10/31/2006 09:10:00 6.6 1.3 9.9 4.6 6.7 1.2 9.9 4.6 6.7 1.2 9.9 4.6 328 10 339 165 3 0 3.3 2.8 10/31/2006 09:20:00 8.3 1.3 11.1 5.3 8.2 1.2 11.1 5.3 8 1.2 10.7 5.3 336 8 328 165 3 0 3.5 2.8 10/31/2006 09:30:00 8 1 11.1 5.3 8 1 10.7 4.2 7.5 1.1 10.3 4.6 335 9 335 165 3.5 0.1 3.8 3.3 10/31/2006 09:40:00 7.6 1.3 10.7 4.6 7.5 1.3 10.7 4.6 7.1 1.3 10.7 3.8 337 13 343 165 3.9 0.1 4.3 3.5 10/31/2006 09:50:00 7.7 1.6 12.2 3.8 7.6 1.6 12.6 3.8 6.9 1.7 10.3 1.9 339 12 342 165 4.1 0.2 4.8 3.5 10/31/2006 10:00:00 7.9 1.4 11.8 4.2 7.5 1.5 11.1 3.8 7.2 1.3 9.9 3.4 344 12 339 165 4.1 0 4.5 3.8 10/31/2006 10:10:00 8.5 1.1 11.1 5.7 8 1.3 11.5 4.6 7.8 1.3 11.5 4.2 343 10 350 165 4.1 0.2 4.8 3.5 10/31/2006 10:20:00 10.4 1.7 13.7 4.9 10.1 1.9 14.1 5.3 9.8 1.7 14.1 4.9 344 8 344 165 3.8 0 4.3 3.5 10/31/2006 10:30:00 9.7 1.7 14.5 5.7 9.4 1.7 14.5 5.3 9.1 1.7 13.7 4.6 338 10 335 165 3.3 0.2 3.8 2.8 10/31/2006 10:40:00 9.5 1.5 13.3 5.3 9.1 1.7 13.3 4.6 9 1.5 12.6 5.3 341 11 338 165 3.2 0.1 3.5 2.6 10/31/2006 10:50:00 6.9 1.3 10.7 4.2 6.4 1.5 10.3 3.4 6.5 1.4 10.3 3.8 344 12 334 165 3.6 0.2 4.3 2.8 10/31/2006 11:00:00 7.1 1.6 11.5 3.8 7.1 1.6 11.1 3 6.7 1.6 11.1 3.8 329 13 325 165 3.8 0.2 4.3 3.5 10/31/2006 11:10:00 7.8 1.7 12.2 3.8 7.7 1.7 12.2 4.2 7.4 1.8 11.8 3.4 332 10 340 165 4.3 0.1 4.8 3.8 10/31/2006 11:20:00 8.2 1.3 12.2 4.9 8 1.5 12.2 4.6 8.2 1.2 11.8 4.9 334 12 340 165 4 0.1 4.5 3.8 10/31/2006 11:30:00 8.9 1.1 12.2 6.1 8.8 1.1 11.8 6.1 8.6 1.1 11.1 5.3 328 11 330 165 3.6 0.1 4 2.8 10/31/2006 11:40:00 10.2 1.4 13.7 6.8 10.2 1.4 13.7 6.8 9.9 1.6 14.1 5.7 328 10 335 165 3.6 0 4 3.5 10/31/2006 11:50:00 10.3 1.2 14.1 7.2 9.4 1.7 14.9 4.9 9.9 1.3 14.1 7.2 343 12 336 165 3.5 0.1 3.8 2.8 10/31/2006 12:00:00 11.4 1.2 14.5 8 11.3 1.6 14.9 6.8 11.3 1.2 14.1 6.8 342 9 348 165 3.4 0 3.5 3.3 10/31/2006 12:10:00 11.6 1.2 14.9 9.1 10.9 1.9 15.3 6.1 11.5 1.2 15.6 8.4 345 9 342 165 3.3 0 3.5 3.3 10/31/2006 12:20:00 11.4 1.5 14.9 5.3 11.3 1.9 15.3 4.9 11 1.4 14.1 6.8 341 9 338 165 3.3 0 3.5 3 10/31/2006 12:30:00 12.8 1.7 18.7 7.2 12.6 2 18.3 7.6 12 1.7 16.8 6.8 342 8 339 165 3.3 0.1 3.8 3 10/31/2006 12:40:00 12.3 1.4 16.1 7.2 12 2.1 16.4 6.1 12 1.5 16.1 7.2 344 9 348 165 3.3 0.1 3.5 2.8 10/31/2006 12:50:00 11.7 1.3 15.6 8 11.5 1.5 15.6 6.8 11.3 1.6 15.3 7.2 338 9 343 165 3.4 0.1 3.8 3 10/31/2006 13:00:00 10.8 1.4 14.1 7.2 10.3 1.8 13.7 4.9 10.1 1.3 13.3 6.5 340 11 336 165 3.3 0.2 3.8 2.8 10/31/2006 13:10:00 12.4 1.7 15.6 7.2 12.3 1.7 15.3 7.2 11.6 1.7 15.6 7.2 336 7 338 165 3.4 0.2 3.8 3 10/31/2006 13:20:00 12.4 1.7 15.3 6.1 11.9 1.9 14.9 5.3 11.9 1.8 16.1 5.7 333 14 359 165 3.4 0.1 3.8 2.8 10/31/2006 13:30:00 13.1 2 17.6 7.2 12.9 2.1 17.2 7.2 12.8 1.9 16.8 6.8 337 8 336 165 4 0.2 4.5 3.3 10/31/2006 13:40:00 13.5 1.4 17.2 8.4 13.4 1.5 16.8 7.6 13.2 1.3 17.6 9.1 338 7 334 165 3.9 0.1 4.5 3.5 10/31/2006 13:50:00 14.4 1.5 17.6 10.7 14.3 1.5 17.2 10.3 14.1 1.6 17.9 9.5 339 6 331 165 4 0.2 4.5 3.5 10/31/2006 14:00:00 14.9 1.5 19.5 10.7 14.7 1.7 19.9 8 14.4 1.7 19.9 9.5 338 7 344 165 4.1 0.1 4.5 3.5 10/31/2006 14:10:00 13.9 1.7 17.9 9.5 13.6 2.1 17.9 5.7 13.3 1.8 17.6 8.4 336 9 325 165 4.3 0 4.5 3.8 10/31/2006 14:20:00 13.1 2 17.9 7.2 12.9 1.9 17.9 7.2 12.1 1.8 16.8 7.6 331 11 334 165 4 0 4.3 3.8 10/31/2006 14:30:00 12.5 2.6 19.9 6.5 12.3 2.6 19.9 5.7 11.8 2.5 17.9 6.1 338 9 325 165 3.6 0.1 4 3 10/31/2006 14:40:00 11.5 2.4 16.4 6.1 11.4 2.4 16.1 6.1 10.7 2.3 16.1 4.2 331 9 325 165 3.6 0.1 4.3 3.3 10/31/2006 14:50:00 11.4 2.4 17.2 5.3 11.3 2.3 17.6 5.7 10.4 2.3 16.1 5.3 329 11 350 165 3.5 0.1 4 3.3 10/31/2006 15:00:00 12.1 2.4 17.9 6.1 11.8 2.5 17.6 4.9 11 2.3 16.1 5.7 330 11 333 165 3.3 0.2 3.8 2.6 10/31/2006 15:10:00 11.8 2.4 17.6 4.9 11.4 2.6 16.8 3.4 10.9 2.3 17.2 5.3 339 15 336 165 3.5 0.2 3.8 3 10/31/2006 15:20:00 9.9 2.6 14.9 2.6 9.8 2.6 14.9 3.4 8.9 2.7 14.9 2.6 328 16 315 165 3.6 0.1 3.8 3 10/31/2006 15:30:00 11.5 1.9 16.1 7.6 11.4 2 15.6 4.6 10.9 2 16.4 6.5 331 11 328 165 3.2 0 3.5 3 10/31/2006 15:40:00 12.7 1.6 17.2 7.6 12.6 1.5 16.4 8.4 11.9 1.7 16.4 7.2 331 9 330 165 3.2 0 3.5 3 10/31/2006 15:50:00 12.1 1.9 16.8 6.8 11.7 2.2 17.2 4.6 11.1 1.7 16.1 6.8 332 12 323 165 3.6 0.1 4 3.3 10/31/2006 16:00:00 11.7 1.8 17.9 6.1 11.5 2 17.6 5.3 11.3 1.8 17.9 5.7 335 9 336 165 3.2 0.2 3.5 2.6 10/31/2006 16:10:00 10 2.1 16.1 3.4 9.8 2.1 15.6 4.2 9.6 2 15.3 3.8 333 13 328 165 2.9 0.2 3.5 2.3 10/31/2006 16:20:00 12.5 2 16.8 6.8 12.4 2.2 17.6 4.6 11.6 1.9 16.1 6.8 339 9 343 165 2.3 0 2.8 1.8 10/31/2006 16:30:00 11.7 1.9 15.3 7.2 11.5 2.1 15.6 6.1 11.2 2.2 15.6 5.3 337 13 332 165 2.2 0 2.6 1.8 10/31/2006 16:40:00 11.4 1.7 15.3 6.1 11.3 1.6 15.3 5.7 10.7 1.8 14.9 4.9 330 11 328 165 2.4 0 2.6 2.3 10/31/2006 16:50:00 11 2 16.1 6.8 10.7 2.1 15.3 6.8 10.4 2 15.3 5.3 339 12 328 165 2.3 0 2.6 2.1 10/31/2006 17:00:00 9.7 1.5 14.5 6.5 9.3 1.5 13.3 5.3 9.4 1.7 14.5 6.1 337 11 354 165 2 0 2.3 1.8 10/31/2006 17:10:00 9 1.7 13.3 4.6 8.9 1.7 12.6 4.6 8.6 1.6 12.2 4.6 336 14 352 165 2 0 2.3 1.8 10/31/2006 17:20:00 7.7 1.9 11.8 3 7.2 1.9 11.8 3 7.3 1.9 11.5 1.9 341 15 358 165 2 0 2.3 1.8 10/31/2006 17:30:00 8.6 1.8 13 4.6 8.4 1.7 12.6 4.9 8.1 1.9 12.6 4.2 334 12 329 165 1.9 0 2.3 1.8 10/31/2006 17:40:00 10.5 1.6 14.9 7.2 10.2 1.7 14.9 5.7 9.9 1.7 14.5 6.1 333 15 339 165 1.9 0 2.3 1.8 10/31/2006 17:50:00 10.6 1.8 17.6 6.1 10.4 1.8 17.9 5.7 10.2 1.9 16.1 6.1 332 9 334 165 2 0 2.3 1.8 10/31/2006 18:00:00 9.9 1.7 13.3 5.7 9.8 1.7 13.3 5.7 9 1.8 13.7 4.6 326 13 331 165 2.1 0 2.6 1.8 10/31/2006 18:10:00 11.4 1.9 15.6 6.8 11.2 2 16.1 6.8 10.8 1.8 15.3 6.1 336 12 347 165 2 0.1 2.3 1.8 10/31/2006 18:20:00 11.8 1.8 16.8 7.2 11.7 1.9 17.6 7.6 10.9 2.2 16.1 5.7 329 12 316 165 1.9 0 2.3 1.8 10/31/2006 18:30:00 11.3 2.5 17.6 5.3 11.1 2.4 16.8 6.1 10.5 2.5 16.1 4.6 334 9 323 165 2 0 2.3 1.8 10/31/2006 18:40:00 11.5 2.5 16.8 6.1 11.2 2.6 16.8 5.7 10.8 2.5 16.8 5.3 330 13 326 165 2.2 0 2.6 2.1 10/31/2006 18:50:00 11.1 2.1 17.9 6.1 10.8 2.4 17.2 4.2 9.9 2.5 17.2 3.4 331 17 334 165 2.3 0 2.6 2.1 10/31/2006 19:00:00 8.6 1.7 13 3.8 8.5 1.7 13 4.2 7.8 1.7 13.3 3 327 16 339 165 2.3 0 2.6 2.3 10/31/2006 19:10:00 8.8 2.5 13.3 3 8.7 2.5 13 3 8 2.6 13 1.9 334 14 334 165 2.3 0 2.6 2.1 10/31/2006 19:20:00 9 2.5 14.5 4.6 8.5 2.6 15.3 3.4 8.5 2.4 14.1 3.8 342 15 344 165 2.4 0 2.6 2.1 10/31/2006 19:30:00 7.9 2.1 13.3 3.4 7.9 2.1 13.3 3.4 7.1 2 12.6 2.6 327 17 350 165 2.4 0 2.8 2.3 10/31/2006 19:40:00 8.3 2.6 15.6 3.8 8.2 2.6 15.3 3.4 7.9 2.6 14.9 1.5 332 17 332 165 2 0.1 2.6 1.8 10/31/2006 19:50:00 9.7 1.9 14.5 5.7 9.4 2.1 14.5 4.9 9.3 1.9 13.7 3 335 14 344 165 2.1 0 2.6 1.8 10/31/2006 20:00:00 9.1 2.3 15.6 3.8 9 2.3 15.6 3.4 8.6 2.1 14.5 3.8 332 13 336 165 2.4 0 2.6 2.3 10/31/2006 20:10:00 8.3 2.5 13.3 2.6 8.2 2.5 13 2.6 7.9 2.5 12.6 2.6 329 16 326 165 2.5 0 2.8 2.3 10/31/2006 20:20:00 8.4 2.1 13.7 3 8.2 2 14.5 3 7.9 2.3 14.5 2.6 327 19 330 165 2.5 0 2.8 2.3 10/31/2006 20:30:00 8.1 1.2 10.7 3.8 8 1.1 10.3 3.8 7.6 1.1 10.3 3.8 327 12 331 165 2.5 0 2.8 2.6 10/31/2006 20:40:00 7.8 2.1 15.3 3.8 7.8 2.2 15.3 3.4 7.4 2.1 13.3 3.4 329 17 349 165 2.6 0 2.8 2.3 10/31/2006 20:50:00 7.9 2.4 14.5 4.6 7.8 2.1 14.1 4.6 7.6 2.7 14.5 3.4 329 17 355 165 2.5 0.1 2.8 2.3 10/31/2006 21:00:00 5.3 1.3 8.8 2.3 5.2 1.5 9.9 1.5 5 1.2 8.4 1.9 342 15 319 165 2.4 0 2.6 2.3 10/31/2006 21:10:00 5.7 1.7 10.3 1.9 5.4 1.8 10.3 1.9 5.5 1.5 9.9 1.1 343 21 325 165 2.4 0 2.8 2.3 10/31/2006 21:20:00 8.3 2.5 13.3 3.4 8.2 2.4 13.3 3 7.3 2.6 13.7 1.9 327 15 330 165 2.5 0 2.8 2.6 10/31/2006 21:30:00 9.2 2 13.3 4.9 9.1 2 13.3 4.9 9 2.1 13.3 4.6 330 12 348 165 2.5 0 2.8 2.3 10/31/2006 21:40:00 7.6 1.9 13 3.8 7.1 1.5 12.6 4.2 7.5 2.1 13 3.4 343 21 346 165 2.4 0 2.8 2.3 10/31/2006 21:50:00 8.7 1.7 12.2 4.2 7.8 2.3 12.2 3 8.6 1.7 13 4.9 355 21 15 165 2.6 0 2.8 2.3 10/31/2006 22:00:00 9.1 1.7 14.1 4.9 9 1.8 13.7 5.3 8.6 1.7 13.7 3.4 326 11 318 165 2.6 0 2.8 2.6 10/31/2006 22:10:00 7.6 1.7 11.5 3.4 7.4 1.8 11.8 3 7.3 1.7 11.8 3 331 16 318 165 2.5 0.1 2.8 2.3 10/31/2006 22:20:00 8.2 1.6 13.7 4.2 7.1 1.6 12.6 3.4 8 1.5 11.5 4.2 356 22 33 165 2.4 0 2.8 2.3 10/31/2006 22:30:00 8.1 1.3 11.5 4.6 7.3 1.4 11.1 3.8 7.9 1.2 11.1 4.6 343 15 323 165 2.3 0 2.6 2.1 10/31/2006 22:40:00 8.2 1.2 11.1 5.3 7.9 1.3 11.1 3.8 7.8 1.2 10.7 4.9 338 16 325 165 2.3 0 2.6 2.3 10/31/2006 22:50:00 7.3 1.9 11.8 2.6 7.1 1.9 12.2 2.6 6.8 1.8 11.5 3 327 21 339 165 2.4 0 2.8 2.3 10/31/2006 23:00:00 7 1.4 10.7 3.8 6.4 1.5 10.7 3 6.9 1.2 9.9 4.2 351 21 322 165 2.3 0 2.8 2.3 10/31/2006 23:10:00 7.9 1.6 11.5 4.2 7.3 1.5 11.1 3.4 7.8 1.4 11.5 4.6 345 17 12 165 2.3 0 2.6 2.1 10/31/2006 23:20:00 8 1.3 13 4.2 6.8 1.5 12.2 3 8 1.3 12.6 4.9 357 13 20 165 2.3 0 2.6 2.1 10/31/2006 23:30:00 6.4 1.2 9.1 3.4 6 1.1 8.8 3.4 6.5 1 8.8 3.8 343 14 329 165 2.3 0 2.6 2.3 10/31/2006 23:40:00 7 1.5 11.1 4.2 6.7 1.7 10.7 2.6 6.9 1.2 10.3 4.2 336 16 325 165 2.3 0 2.6 2.1 10/31/2006 23:50:00 6.9 1.5 11.5 4.2 6.9 1.5 11.8 4.2 6.4 1.4 11.1 3.8 324 14 314 165 2 0 2.6 1.8 11/01/2006 00:00:00 7 1.4 10.3 3.4 7 1.4 10.3 3.4 6.8 1.3 10.3 2.3 332 12 329 165 2.1 0 2.6 1.8 11/01/2006 00:10:00 7.3 1.5 11.5 3.8 7.1 1.7 11.5 3 7.3 1.5 11.8 4.6 334 11 351 165 2.2 0.1 2.6 1.8 11/01/2006 00:20:00 9.2 1.8 13.7 4.6 9.1 1.8 13.3 4.6 9 1.7 13.7 5.3 328 12 319 165 2.4 0 2.8 2.3 11/01/2006 00:30:00 8.4 1.5 14.1 4.6 8.3 1.5 13.3 4.9 8 1.3 11.8 4.9 327 10 327 165 2.4 0 2.8 2.3 11/01/2006 00:40:00 7.9 1.7 12.6 4.2 7.9 1.7 12.2 4.2 7.6 1.6 11.5 4.2 329 10 339 165 2.3 0 2.6 2.1 11/01/2006 00:50:00 7.9 1.6 13 4.2 7.9 1.5 12.6 4.2 7.8 1.5 12.6 4.2 331 9 338 165 2.3 0 2.6 2.1 11/01/2006 01:00:00 8.4 1.5 13.3 4.9 8.1 1.7 13 3.8 8.2 1.4 13 4.9 334 13 329 165 2.2 0 2.6 2.1 11/01/2006 01:10:00 8.7 1.5 12.6 3.8 8.6 1.5 12.2 3.8 8.5 1.5 12.6 5.3 331 9 323 165 2.1 0 2.6 1.8 11/01/2006 01:20:00 7.8 1.6 12.2 5.3 7.7 1.6 11.8 4.6 7.5 1.5 11.5 5.3 334 10 333 165 2 0 2.3 1.8 11/01/2006 01:30:00 8.3 1.7 12.6 4.2 8.2 1.7 13 3.8 7.8 1.6 12.2 4.2 335 9 336 165 1.9 0 2.1 1.6 11/01/2006 01:40:00 9.2 1.5 12.6 5.7 9.1 1.5 12.2 4.9 9 1.5 13.3 5.3 337 9 328 165 1.9 0 2.3 1.8 11/01/2006 01:50:00 11.1 1.5 14.9 7.2 11.2 1.7 14.9 5.3 10.7 1.5 15.3 7.2 343 7 337 165 2 0 2.3 1.8 11/01/2006 02:00:00 10.5 1.3 13.3 6.8 10.6 1.5 13.7 7.2 10.4 1.3 13.3 6.8 342 7 340 165 2 0 2.3 1.8 11/01/2006 02:10:00 9.1 1.5 14.9 6.1 9 1.6 14.5 4.9 8.9 1.5 14.5 5.3 336 12 328 165 2 0.1 2.3 1.8 11/01/2006 02:20:00 9.3 1.8 14.5 5.7 9.1 2 14.5 4.6 9.2 1.7 14.5 5.3 340 9 334 165 2 0 2.3 1.8 11/01/2006 02:30:00 10.1 1.4 13.3 7.2 9.7 1.7 13.7 4.9 10 1.3 13 6.8 345 8 344 165 1.9 0 2.3 1.8 11/01/2006 02:40:00 8.1 1.4 13 5.3 8 1.5 12.6 4.2 7.9 1.3 12.6 5.3 337 10 334 165 1.9 0 2.3 1.6 11/01/2006 02:50:00 9.5 1.3 13 5.7 9.3 1.4 13 5.3 9.2 1.3 12.6 5.7 338 8 333 165 1.8 0 1.8 1.6 11/01/2006 03:00:00 9 1.1 11.5 5.7 9 1.2 12.2 5.3 8.8 1.2 11.5 5.7 339 9 347 165 1.9 0 2.1 1.6 11/01/2006 03:10:00 9.8 1.4 13.7 5.3 9.6 1.6 13.7 5.3 9.6 1.5 14.5 5.7 343 8 344 165 1.8 0 2.1 1.6 11/01/2006 03:20:00 10.3 1.3 13 6.8 10 1.7 13 4.6 10 1.3 13.3 6.5 343 8 336 165 1.9 0 2.3 1.8 11/01/2006 03:30:00 8.4 1.7 13 4.9 8 1.9 13.7 3.8 8.3 1.5 13.3 4.6 341 12 340 165 1.8 0 2.1 1.6 11/01/2006 03:40:00 8.5 1.9 12.2 4.6 8.2 1.9 13 3.8 8.5 1.7 12.6 4.2 341 10 357 165 1.9 0 2.1 1.8 11/01/2006 03:50:00 10 1.5 13.3 6.1 9.8 1.6 13.3 6.1 9.8 1.6 13.3 6.1 342 8 336 165 2 0 2.3 1.8 11/01/2006 04:00:00 10.1 1.1 14.1 7.2 10 1.1 13 6.8 10.2 1.2 13.3 6.8 340 8 350 165 2 0 2.3 1.8 11/01/2006 04:10:00 9.1 1.2 12.6 6.1 8.6 1.7 13 4.2 9.1 1.2 12.2 6.5 342 11 348 165 2 0.1 2.3 1.8 11/01/2006 04:20:00 9.7 1.7 13 5.3 9.6 1.8 13 4.6 9.6 1.8 13 4.2 334 12 336 165 2 0 2.3 1.8 11/01/2006 04:30:00 11 1.3 15.3 8 10.8 1.5 15.3 4.9 10.8 1.5 15.6 7.6 341 9 353 165 2 0 2.3 1.8 11/01/2006 04:40:00 9.5 1.3 14.1 6.8 9.1 1.4 13.7 4.9 9.5 1.5 14.5 6.1 340 11 346 165 2.1 0 2.3 1.8 11/01/2006 04:50:00 9.9 1.4 12.6 6.5 9.6 1.7 13.3 5.7 10.1 1.6 13.7 6.1 341 12 5 165 2.1 0 2.3 1.8 11/01/2006 05:00:00 11.3 1.7 15.3 6.8 11.3 1.8 16.1 6.8 11.2 1.7 15.3 7.2 339 8 349 165 2.1 0 2.6 2.1 11/01/2006 05:10:00 9 1.5 12.6 5.3 8.9 1.5 13.3 4.9 9.1 1.6 13.3 5.7 333 11 338 165 2.2 0 2.6 1.8 11/01/2006 05:20:00 7.9 1.1 11.1 4.9 7.7 1.1 11.1 4.6 7.9 1.1 11.5 5.3 333 13 329 165 2.1 0.1 2.6 1.8 11/01/2006 05:30:00 8.9 2 13.7 4.9 8.8 2.1 14.1 4.9 8.7 2 13.7 5.7 333 12 340 165 2 0 2.3 1.8 11/01/2006 05:40:00 10.5 1.9 16.1 6.1 10.4 2 16.4 5.3 10.3 2 16.4 6.1 338 9 340 165 2.1 0 2.3 1.8 11/01/2006 05:50:00 11.9 1.6 15.6 7.2 11.4 2 15.3 5.3 11.9 1.7 16.4 7.2 344 9 356 165 2.1 0 2.6 1.8 11/01/2006 06:00:00 10.9 1.4 14.1 7.2 10.8 1.6 14.9 6.8 10.8 1.5 14.5 7.2 339 9 344 165 2.1 0 2.6 1.8 11/01/2006 06:10:00 10 2.1 14.5 5.3 9.4 2.2 14.5 3.8 10 2 14.1 6.1 344 12 339 165 2.1 0 2.6 1.8 11/01/2006 06:20:00 10.4 2.3 14.5 5.7 10 2.5 15.3 4.9 10.5 2.1 14.9 6.8 341 12 355 165 2.1 0 2.3 1.8 11/01/2006 06:30:00 11.9 1.5 14.9 8.4 11.8 1.7 15.3 6.5 11.9 1.5 14.9 7.2 341 8 338 165 2 0 2.3 1.8 11/01/2006 06:40:00 8.4 1.8 14.1 4.6 7.9 1.9 13.7 4.2 8.2 1.8 14.5 4.2 335 21 356 165 2 0.1 2.3 1.8 11/01/2006 06:50:00 9 1.2 12.2 6.1 8.3 1.5 12.2 4.6 8.9 1.3 12.2 5.3 344 14 1 165 1.9 0 2.1 1.8 11/01/2006 07:00:00 5.8 1.2 8.4 2.6 5.8 1.2 8 1.9 5.3 1.1 8 2.3 317 18 350 165 1.8 0 2.1 1.6 11/01/2006 07:10:00 6.1 0.8 8.8 4.2 6.1 0.8 8.4 3.8 5.9 0.9 8.4 3.8 322 12 328 165 1.5 0 1.8 1.4 11/01/2006 07:20:00 5.9 1.2 9.1 3 6 1.2 9.9 2.6 6.1 1.2 9.9 3.4 326 12 345 165 1.7 0 1.8 1.6 11/01/2006 07:30:00 8.6 1.9 13 3.4 8.5 1.9 12.2 3.8 8.4 1.9 12.6 3 326 15 334 165 1.8 0.1 2.1 1.6 11/01/2006 07:40:00 7.8 1.9 12.6 4.2 7.8 1.9 12.6 3 7.8 2 13.3 4.2 330 15 334 165 1.8 0 2.1 1.6 11/01/2006 07:50:00 6.9 1.4 10.3 4.2 6.9 1.3 10.7 4.6 6.9 1.3 10.7 4.6 328 9 334 165 1.7 0 1.8 1.6 11/01/2006 08:00:00 8.1 1.5 11.5 4.2 8 1.5 11.8 4.6 8.1 1.3 11.5 4.6 334 11 345 165 1.7 0 1.8 1.6 11/01/2006 08:10:00 7.3 1.7 12.6 4.6 7.3 1.5 12.2 4.9 7.4 1.7 12.6 4.2 327 12 338 165 1.8 0 2.1 1.6 11/01/2006 08:20:00 8.3 1.6 13.3 3.8 8.2 1.6 13.3 4.2 8.3 1.7 13.7 3.8 328 12 339 165 1.7 0 1.8 1.4 11/01/2006 08:30:00 8.1 1.3 11.8 4.9 8.1 1.3 11.8 5.3 8.1 1.3 11.8 4.9 331 11 320 165 1.8 0.1 2.1 1.6 11/01/2006 08:40:00 8.4 1.4 13.3 4.6 8.1 1.4 13 4.9 8.4 1.3 11.8 4.9 338 11 343 165 2 0 2.3 1.8 11/01/2006 08:50:00 8 1.6 13.3 3.8 7.9 1.6 13.3 2.6 8 1.7 13.7 3.8 330 15 332 165 2.3 0 2.6 2.1 11/01/2006 09:00:00 7.6 1.6 11.1 3.8 7.5 1.6 11.1 3 7.6 1.5 11.8 4.6 329 13 325 165 2.4 0 2.8 2.3 11/01/2006 09:10:00 7.6 1.6 11.8 3 7.5 1.7 11.5 2.6 7.5 1.6 11.8 2.6 333 15 332 165 2.6 0 2.8 2.6 11/01/2006 09:20:00 9.8 1.6 13.7 5.7 9.5 1.7 14.1 5.7 9.6 1.6 14.1 5.7 334 12 325 165 2.7 0 3 2.6 11/01/2006 09:30:00 10 2 14.9 5.3 9.7 2.4 15.3 4.6 9.9 1.9 14.1 5.3 337 13 342 165 2.8 0 3 2.6 11/01/2006 09:40:00 8.2 1.7 13.7 4.6 8.1 1.8 14.5 4.2 8.2 1.7 13.3 4.9 336 15 346 165 2.9 0.1 3.3 2.6 11/01/2006 09:50:00 7 1.4 10.7 3.4 6.5 1.4 10.3 2.6 7 1.5 11.1 3.8 340 17 353 165 3.2 0 3.5 3 11/01/2006 10:00:00 8.3 1.9 14.5 5.3 8.1 1.9 13.7 4.9 8.6 1.9 15.6 5.7 337 10 334 165 3.2 0 3.5 2.8 11/01/2006 10:10:00 8.5 1.5 13.3 4.2 7.8 1.6 11.5 4.2 8.3 1.5 12.6 4.2 343 15 3 165 3.2 0 3.5 2.8 11/01/2006 10:20:00 4.5 1 6.8 1.9 4.5 1 6.8 1.9 4.4 1 7.6 2.3 314 24 276 165 3.4 0.3 4.3 2.8 11/01/2006 10:30:00 4.7 0.8 6.8 2.6 4.4 1 6.8 1.1 4.9 0.8 6.8 3 342 11 338 165 4.1 0.1 4.5 3.5 11/01/2006 10:40:00 6.8 1.4 11.1 3.8 6.3 1.6 11.5 3.4 6.9 1.3 10.7 3.8 342 15 332 165 3.9 0 4.5 3.5 11/01/2006 10:50:00 6 1.6 9.9 2.3 5.6 1.5 9.5 1.5 6.1 1.9 11.5 1.9 338 22 354 165 3.7 0.1 4 3.5 11/01/2006 11:00:00 5.5 1.2 9.9 3.4 4.9 1.5 9.9 2.3 5.6 1.2 9.5 3.4 349 11 338 165 4 0.2 4.5 3.5 11/01/2006 11:10:00 7.1 1.8 12.6 0.7 6.1 1.7 12.2 1.9 7.3 1.7 12.6 3 349 17 356 165 4.2 0.2 4.5 3.5 11/01/2006 11:20:00 6.4 1.5 11.5 3 6.3 1.5 11.5 2.6 6.1 1.3 11.1 3.8 321 23 294 165 3.8 0.2 4.3 3.5 11/01/2006 11:30:00 6.3 1.7 10.3 1.9 5.7 1.5 10.3 1.5 6.3 1.7 10.3 1.5 348 20 355 165 3.8 0.1 4.3 3.5 11/01/2006 11:40:00 6.3 1.3 10.7 3.8 6 1.3 9.5 2.3 6.4 1.4 11.1 3.4 346 10 4 165 4.3 0 4.5 4 11/01/2006 11:50:00 5.6 1.3 9.9 2.6 5.2 1.3 8.4 2.6 5.7 1.6 9.9 2.3 338 22 355 165 4.3 0 4.5 4 11/01/2006 12:00:00 7.2 1.8 11.5 2.6 6.3 1.5 10.7 2.6 7.5 1.8 11.5 3.4 349 12 360 165 4.3 0.1 4.8 4 11/01/2006 12:10:00 7.8 1.3 12.2 4.6 7.4 1.3 11.1 3.8 7.8 1.3 12.2 4.6 346 9 356 165 4.3 0 4.8 4 11/01/2006 12:20:00 8.6 1.2 12.2 5.3 8.2 1.4 11.8 4.9 8.8 1.2 13 5.7 345 8 357 165 4.2 0.1 4.8 4 11/01/2006 12:30:00 7.7 1.3 10.7 4.6 7.1 1.5 10.7 3 7.7 1.3 10.7 4.2 340 17 338 165 4.4 0 5 4.3 11/01/2006 12:40:00 7.3 1.2 10.3 4.2 7.1 1.3 11.1 4.2 7.2 1.3 10.3 3.8 338 10 342 165 4.5 0.1 4.8 4.3 11/01/2006 12:50:00 8.7 1.7 12.2 4.6 8.6 1.7 11.8 4.9 8.6 1.7 12.2 4.9 334 10 333 165 4.3 0 4.8 4 11/01/2006 13:00:00 8.2 1.8 12.6 4.9 8.1 1.8 13 4.2 8.3 1.8 13.7 4.6 336 13 344 165 4.1 0.1 4.5 3.8 11/01/2006 13:10:00 9.1 2.1 13.3 3.4 8.7 2.1 13 3.4 8.8 2 13 3.8 337 17 327 165 4.3 0 4.5 4 11/01/2006 13:20:00 8.7 2.3 14.5 1.5 8.4 2.3 14.5 1.9 8.9 2.1 13.7 2.3 344 19 339 165 4.1 0.1 4.5 3.8 11/01/2006 13:30:00 8.8 1.7 13.3 4.9 8.5 1.7 13 4.9 8.9 1.8 14.1 4.9 337 12 353 165 4.2 0.1 4.5 4 11/01/2006 13:40:00 8 1.9 11.8 4.6 8 1.8 12.6 4.9 8.2 2 12.2 4.6 338 9 340 165 4.5 0 4.8 4.3 11/01/2006 13:50:00 6.7 1.2 9.9 4.2 6.2 1.1 9.5 3.4 6.8 1.3 10.3 3.8 341 14 2 165 4.8 0 5 4.5 11/01/2006 14:00:00 5.1 0.9 8 2.6 5 0.8 7.6 2.3 5.1 1.1 7.6 2.6 326 18 5 165 5.1 0.1 5.7 4.8 11/01/2006 14:10:00 6.7 1 9.5 4.6 6.7 1 9.5 4.6 5.9 1 8.4 2.6 307 10 302 165 4.9 0.4 5.7 4.3 11/01/2006 14:20:00 6 0.9 8.4 4.2 6 1 8.4 3 6 0.7 8 4.2 327 16 314 165 4.4 0 4.8 4.3 11/01/2006 14:30:00 5.3 0.9 8 3 5.4 0.9 8 3 5.2 0.9 8 3 323 12 321 165 4.9 0.1 5.2 4.5 11/01/2006 14:40:00 5.8 1 8.4 3.8 5.9 1 8.8 3.8 5.8 1 8.4 3 332 17 346 165 4.9 0.2 5.5 4.5 11/01/2006 14:50:00 5.8 1.2 9.1 2.6 5.9 1.2 8.8 3 5.4 1.2 8 3 312 17 297 165 4.9 0.2 5.7 4.5 11/01/2006 15:00:00 5.2 1.3 9.9 2.6 4.6 1 7.6 2.6 5 1.2 9.1 3 343 15 13 165 5.1 0.3 5.7 4.5 11/01/2006 15:10:00 5 1 7.2 2.6 5 0.9 7.2 3 4.9 1 7.2 2.3 326 15 312 165 5.4 0.1 5.7 5.2 11/01/2006 15:20:00 4.5 0.8 6.5 2.3 4.5 0.8 6.5 2.3 3.9 0.8 5.7 1.9 319 17 307 165 5.6 0.1 6 5.5 11/01/2006 15:30:00 4.8 0.7 6.1 3 4.8 0.7 6.1 3 4.5 0.7 6.1 2.3 322 8 321 165 5.6 0.4 6.5 4.8 11/01/2006 15:40:00 5.6 0.8 8 4.2 5 1.3 8 2.3 5.6 1 8.4 3.8 342 16 359 165 5.1 0 5.5 4.8 11/01/2006 15:50:00 5.6 0.9 7.6 3 5.5 0.9 7.6 3 5.5 1 7.6 3.4 328 14 338 165 4.8 0 5 4.5 11/01/2006 16:00:00 6 1 8.4 3.4 5.4 1.3 8.8 1.9 6.1 1 8.8 3.4 348 12 347 165 4.6 0 4.8 4.3 11/01/2006 16:10:00 5.3 0.6 6.8 4.2 5.4 0.5 6.8 3.8 5.6 0.6 7.2 4.2 332 10 333 165 4 0 4.5 3.8 11/01/2006 16:20:00 6.5 0.8 8.8 4.6 6.1 1.2 9.1 3 6.8 0.7 9.1 4.6 346 11 327 165 3.8 0 4 3.5 11/01/2006 16:30:00 6.8 1 9.5 4.6 6.4 1.2 9.1 3.4 7.2 1 9.5 4.9 344 10 360 165 3.6 0.1 4.3 2.8 11/01/2006 16:40:00 6 1.3 9.5 2.3 5.6 1.4 9.5 2.6 6.1 1.3 9.5 3.4 346 12 342 165 3.4 0 3.5 3.3 11/01/2006 16:50:00 5.5 1 9.1 2.3 5.5 1 9.5 3 5.6 1.1 8.8 3 334 11 349 165 3 0.2 3.8 2.6 11/01/2006 17:00:00 5.5 0.9 7.6 3.4 5.5 0.9 7.6 3.4 5.5 0.9 8 2.6 334 10 319 165 2.3 0.1 2.8 1.8 11/01/2006 17:10:00 4 0.8 6.1 2.3 3.7 1.2 6.1 1.1 4.1 0.9 6.5 2.6 349 16 328 165 2 0 2.3 1.8 11/01/2006 17:20:00 4.4 1.1 7.2 2.3 4.3 1.4 7.2 1.1 4.4 1 7.2 2.3 340 13 344 165 1.7 0.1 2.1 0.9 11/01/2006 17:30:00 5.6 0.7 7.6 3.4 5.7 0.8 7.6 3 5.7 0.8 7.6 3.8 341 9 333 165 1.7 0 1.8 1.6 11/01/2006 17:40:00 4.6 1 7.6 2.6 4.8 1 7.2 2.6 4.7 1 7.6 2.6 331 10 338 165 1.8 0 2.1 1.4 11/01/2006 17:50:00 5 0.9 6.8 2.6 5 1 7.2 2.6 4.9 0.9 7.2 3 332 10 333 165 1.5 0 1.8 1.4 11/01/2006 18:00:00 4.1 0.9 6.5 2.3 4.1 0.9 6.8 2.3 4.2 0.8 6.1 2.3 333 10 340 165 1.7 0 1.8 1.4 11/01/2006 18:10:00 4.9 1 8 3 5 1 8 1.9 4.9 1 7.6 3 335 12 331 165 1.7 0 1.8 1.4 11/01/2006 18:20:00 5 0.8 6.8 3 5.1 0.8 7.2 3 5.1 0.8 7.6 3.8 330 9 344 165 1.7 0 1.8 1.4 11/01/2006 18:30:00 4.4 1 6.5 2.3 3.9 1.3 6.5 1.1 4.3 0.8 6.5 2.6 342 14 327 165 1.4 0.2 1.8 0.7 11/01/2006 18:40:00 5.5 1 8 2.6 5.2 1.1 8 2.6 5.5 1.3 9.5 2.6 334 17 321 165 1.4 0 1.6 0.9 11/01/2006 18:50:00 5.7 1 9.1 3 5.7 1 9.1 2.6 5.8 1 8.8 2.6 331 12 343 165 1.7 0.1 2.1 1.1 11/01/2006 19:00:00 6.2 0.8 8 4.2 6.3 0.8 8.4 4.2 6.2 0.8 8 3.8 338 7 337 165 1.6 0 1.8 1.4 11/01/2006 19:10:00 5.6 0.7 8 4.2 5.7 0.7 8 4.2 5.6 0.8 8 3.8 336 9 328 165 1.5 0.1 1.8 1.1 11/01/2006 19:20:00 6 0.9 8 4.2 5.9 1.1 8.4 3 6.2 0.8 8.8 4.2 344 8 354 165 1.4 0.1 1.6 0.9 11/01/2006 19:30:00 5.6 1 8 2.6 5.7 1 8 3 5.8 0.9 7.6 3 339 8 339 165 1.5 0.1 1.8 0.9 11/01/2006 19:40:00 4.8 0.6 6.5 3.4 5 0.7 6.8 3.4 5 0.6 6.5 3.8 337 7 334 165 1.3 0.1 1.6 0.7 11/01/2006 19:50:00 4.5 0.8 6.5 2.3 4.6 0.9 6.8 2.6 4.6 0.7 6.5 3 338 7 337 165 1.2 0 1.6 1.1 11/01/2006 20:00:00 4.9 0.8 6.5 3 5 0.9 6.8 2.6 5.1 0.9 7.2 2.6 329 7 330 165 1.4 0 1.8 1.1 11/01/2006 20:10:00 4.9 0.6 6.5 3.4 5 0.7 6.8 3.4 5 0.8 7.2 2.3 338 9 320 165 1.2 0.1 1.6 0.9 11/01/2006 20:20:00 4.4 0.6 6.8 3 4.3 0.6 7.2 3 4.5 0.6 7.2 3 327 9 347 165 0.9 0.1 1.4 0.9 11/01/2006 20:30:00 4.8 0.7 7.2 3.4 4.9 0.8 7.6 3 5 0.7 6.8 3 337 8 340 165 0.9 0 1.1 0.7 11/01/2006 20:40:00 4.7 0.5 6.5 3.8 4.6 0.8 6.5 2.3 4.9 0.5 6.5 3.4 343 8 325 165 0.8 0 1.4 0.7 11/01/2006 20:50:00 3.6 0.9 5.7 1.9 3.7 1 6.5 2.3 3.9 0.8 6.5 2.6 327 9 338 165 0.7 0.1 0.9 0.7 11/01/2006 21:00:00 2.8 0.8 5.7 1.1 2.8 0.8 6.1 1.1 3 0.6 5.3 1.9 326 14 333 165 0.7 0 1.1 0.7 11/01/2006 21:10:00 3.5 1 6.1 1.5 3.3 1.1 5.7 1.5 3.7 0.9 5.7 2.3 336 13 348 165 0.8 0 1.4 0.7 11/01/2006 21:20:00 2.2 0.5 3.4 1.1 2.1 0.6 3.4 0.4 2.6 0.5 3.8 1.1 331 15 333 165 0.8 0.1 1.4 0.7 11/01/2006 21:30:00 0.9 0.6 2.6 0.4 0.8 0.6 2.6 0.4 1.3 0.7 3 0.4 327 22 344 165 0.8 0.1 1.4 0.7 11/01/2006 21:40:00 1.2 0.6 3 0.4 1.2 0.6 3 0.4 1.6 0.5 3 0.4 338 38 349 165 0.9 0 1.4 0.7 11/01/2006 21:50:00 1.4 0.4 2.3 0.4 1.3 0.5 2.6 0.4 2.1 0.5 3 0.7 330 24 287 165 0.7 0.1 1.4 0.4 11/01/2006 22:00:00 1.2 0.8 3.8 0.4 1.2 0.8 3.4 0.4 1.5 0.7 3.4 0.4 310 26 324 165 0.7 0.1 1.1 0.2 11/01/2006 22:10:00 2 0.9 3.8 0.4 2.1 0.8 3.8 0.4 2.6 0.7 4.2 1.1 317 22 339 165 0.7 0 0.9 0.7 11/01/2006 22:20:00 0.7 0.5 2.6 0.4 0.9 0.6 2.6 0.4 1.4 0.6 3 0.4 289 15 287 165 0.8 0 1.1 0.7 11/01/2006 22:30:00 1.9 1.2 3.8 0.4 1.9 1.2 4.2 0.4 2.4 1.2 4.2 0.4 333 12 328 165 0.9 0.1 1.4 0.7 11/01/2006 22:40:00 0.8 0.5 2.3 0.4 1 0.6 2.3 0.4 1.6 0.5 3 0.7 284 26 346 165 0.6 0 0.9 0.2 11/01/2006 22:50:00 0.7 0.5 2.6 0.4 0.8 0.6 2.6 0.4 1.4 0.7 3 0.4 278 17 301 165 0.5 0 0.9 0.2 11/01/2006 23:00:00 1.2 0.7 3 0.4 1.3 0.7 3 0.4 1.8 0.6 3 0.4 300 18 333 165 0.5 0 0.7 0.2 11/01/2006 23:10:00 2.2 0.6 3.4 0.4 2.3 0.5 3.4 0.4 2.3 0.5 3.4 1.1 291 11 277 165 0.6 0 0.9 0.4 11/01/2006 23:20:00 2.5 0.6 4.2 0.7 2.7 0.6 4.2 1.1 2.6 0.5 4.2 1.5 292 7 285 165 0.5 0 0.9 0.2 11/01/2006 23:30:00 1.4 0.6 3 0.4 1.5 0.7 3 0.4 2 0.5 3.4 0.7 317 19 319 165 0.7 0 0.9 0.4 11/01/2006 23:40:00 1.9 1 4.2 0.4 2.1 0.9 4.2 0.4 2.3 0.8 4.6 0.7 311 11 315 165 0.8 0.2 1.4 0.4 11/01/2006 23:50:00 1.3 0.6 3 0.4 1.4 0.6 3 0.4 1.8 0.4 2.6 0.7 316 13 340 165 0.4 0 0.9 -0.1 11/02/2006 00:00:00 1.3 0.6 2.6 0.4 1.4 0.6 3 0.4 1.8 0.5 3 0.7 313 19 309 165 0.6 0 0.9 0.4 11/02/2006 00:10:00 0.9 0.5 2.3 0.4 1.1 0.5 2.3 0.4 1.5 0.3 2.6 0.7 298 9 293 165 0.9 0.1 1.1 0.7 11/02/2006 00:20:00 1.7 0.7 3.4 0.4 1.9 0.7 3.4 0.7 2.3 0.5 3.4 1.5 315 9 310 165 0.5 0 0.9 0.4 11/02/2006 00:30:00 2.4 0.8 4.2 0.4 2.6 0.8 4.2 0.4 2.7 0.5 3.8 1.5 309 12 307 165 0.5 0 0.9 0.2 11/02/2006 00:40:00 1.9 0.6 3.4 0.7 2.2 0.5 3.4 0.7 2.2 0.4 3.4 1.1 317 17 338 165 0.2 0 0.4 -0.1 11/02/2006 00:50:00 2.4 0.7 3.8 0.4 2.6 0.7 4.2 1.1 2.8 0.6 3.8 1.1 327 15 325 165 0.4 0.1 0.7 -0.1 11/02/2006 01:00:00 2.6 0.5 4.2 1.1 2.7 0.5 4.2 1.5 3 0.4 3.8 1.5 337 8 344 165 0.1 0 0.7 -0.1 11/02/2006 01:10:00 4.8 1.1 7.2 2.3 4.7 1.2 7.6 1.9 4.9 1 7.2 2.6 345 6 341 165 -0.2 0.2 0.4 -0.5 11/02/2006 01:20:00 6.1 0.8 8.4 4.6 6.3 0.8 8.4 4.2 6.3 0.8 8.8 4.6 341 9 351 165 -0.1 0 0.2 -0.5 11/02/2006 01:30:00 5.6 0.6 7.2 4.2 5.7 0.6 7.2 3 5.9 0.5 7.2 4.6 337 8 319 165 -0.1 0 0.7 -0.3 11/02/2006 01:40:00 5.8 0.8 8.4 4.6 6 0.8 8 3.8 6.1 0.9 8.4 3.8 340 8 339 165 0.1 0.1 0.4 -0.1 11/02/2006 01:50:00 6.4 1 9.1 4.2 6.3 1 9.1 3 6.7 0.9 9.1 4.9 345 7 356 165 0.1 0 0.7 -0.1 11/02/2006 02:00:00 6.6 0.7 9.1 4.6 6.6 0.8 8.4 4.6 6.9 0.7 9.5 5.3 346 6 348 165 0.2 0 0.7 -0.1 11/02/2006 02:10:00 5.5 0.7 7.2 3.8 5.6 1 8 2.6 5.8 0.7 7.6 4.2 342 8 343 165 0.1 0 0.7 -0.3 11/02/2006 02:20:00 5.2 0.6 6.5 3.8 5.2 0.9 6.8 1.9 5.5 0.6 6.8 3.4 344 7 339 165 -0.3 0 0.2 -0.5 11/02/2006 02:30:00 5 0.7 7.6 3.4 4.8 1 7.6 1.9 5.2 0.7 7.6 3.8 346 8 332 165 -0.3 0 -0.1 -0.5 11/02/2006 02:40:00 5.4 0.7 7.2 3.4 5.3 1 8 2.6 5.7 0.7 7.6 3.8 346 7 345 165 -0.3 0 -0.1 -0.5 11/02/2006 02:50:00 4.2 0.7 6.1 2.3 4.1 0.9 6.5 1.9 4.5 0.6 6.5 2.6 336 11 334 165 -0.4 0 0.2 -0.8 11/02/2006 03:00:00 4.7 0.6 6.5 3.4 4.8 0.7 6.5 3.4 4.8 0.7 6.8 2.6 321 9 334 165 -0.3 0 -0.1 -0.5 11/02/2006 03:10:00 5.1 0.8 7.2 3.4 4.8 0.9 7.2 2.3 5.2 0.7 6.8 3.8 338 15 346 165 -0.3 0 -0.1 -0.5 11/02/2006 03:20:00 4.7 0.5 6.1 3.4 4.8 0.6 6.8 3.4 4.8 0.5 6.5 3.4 321 10 343 165 -0.4 0 -0.1 -0.8 11/02/2006 03:30:00 4.9 0.6 6.5 3.4 4.9 0.6 6.5 3.4 4.6 0.6 6.5 3 311 6 313 165 -0.5 0.1 -0.3 -0.8 11/02/2006 03:40:00 4.8 0.4 6.5 3.8 4.7 0.4 6.5 3.4 4.2 0.6 5.7 2.6 307 6 299 165 -0.6 0.2 -0.1 -1 11/02/2006 03:50:00 4.5 0.6 6.1 3 4.4 0.6 6.1 2.6 4 0.5 5.3 2.6 312 13 308 165 -1 0 -0.8 -1.2 11/02/2006 04:00:00 4.2 0.6 5.7 2.6 4.1 0.7 5.7 2.6 3.7 0.5 4.9 2.3 307 10 309 165 -0.9 0 -0.5 -1 11/02/2006 04:10:00 4.8 0.7 6.8 3 4.7 0.7 6.5 2.6 4.2 0.7 5.7 2.3 308 9 307 165 -0.8 0 -0.5 -1.2 11/02/2006 04:20:00 5.2 0.5 7.2 4.2 5.3 0.5 6.8 3.8 4.7 0.5 6.1 3 307 6 303 165 -0.6 0 -0.3 -0.8 11/02/2006 04:30:00 5.5 0.6 7.2 4.2 5.6 0.6 7.2 3.8 4.5 0.6 6.8 3 300 6 290 165 -0.6 0.1 -0.3 -0.8 11/02/2006 04:40:00 6.3 0.8 8.4 4.2 6.4 0.8 8.4 4.6 5.5 0.9 8 3 298 8 297 165 -0.3 0 -0.1 -0.5 11/02/2006 04:50:00 6.2 0.9 8 3.8 6.3 0.9 8 3.4 5.5 0.8 8 3.4 297 9 289 165 -0.3 0 -0.1 -0.5 11/02/2006 05:00:00 5.7 0.7 7.2 3.8 5.9 0.7 7.2 3.8 5.1 0.6 6.8 3.4 307 11 297 165 -0.7 0.1 -0.3 -0.8 11/02/2006 05:10:00 5.1 0.7 7.2 3.4 5.2 0.8 7.2 3 5.3 0.8 8 3 326 12 328 165 -0.3 0.2 -0.1 -0.8 11/02/2006 05:20:00 5.2 0.8 7.6 3.4 5.3 0.8 8 3.8 5.2 0.8 8.8 3.8 317 10 319 165 -0.3 0 -0.1 -0.5 11/02/2006 05:30:00 6.5 0.8 9.5 4.2 6.6 0.8 9.1 4.6 5.8 1 8.8 3.4 307 9 317 165 -0.5 0 -0.1 -0.8 11/02/2006 05:40:00 7 0.7 9.1 4.9 7 0.6 8.8 5.3 6 0.8 8.4 4.2 307 7 313 165 -0.6 0 -0.3 -0.8 11/02/2006 05:50:00 8.1 0.8 9.9 4.9 8 0.8 9.9 4.9 6.4 0.8 8.4 4.2 301 7 295 165 -0.6 0 -0.3 -0.8 11/02/2006 06:00:00 8.2 0.9 10.7 5.3 8 0.8 10.3 5.3 6.6 0.8 8.8 4.6 304 6 302 165 -0.6 0.1 -0.3 -1 11/02/2006 06:10:00 7.6 0.9 10.3 5.7 7.6 0.8 9.9 5.7 6.6 0.9 9.9 4.6 309 8 302 165 -0.8 0.1 -0.5 -0.8 11/02/2006 06:20:00 7.3 0.7 9.5 5.3 7.2 0.6 9.1 5.3 6.7 0.8 8.4 4.2 314 11 303 165 -0.8 0 -0.5 -1 11/02/2006 06:30:00 7.4 1 9.9 4.6 7.3 1 9.5 4.6 6.7 1 9.1 3.8 312 10 295 165 -0.7 0 -0.3 -0.8 11/02/2006 06:40:00 6.9 0.8 9.1 4.6 6.8 0.7 8.8 4.9 6.3 0.7 9.1 4.6 311 7 317 165 -0.6 0.1 -0.3 -0.8 11/02/2006 06:50:00 6.5 1.2 10.3 4.2 6.6 1.2 10.3 4.2 6.4 1 8.8 3.8 326 13 329 165 -0.5 0 -0.3 -0.8 11/02/2006 07:00:00 5.8 0.9 7.6 3.4 5.9 0.8 8 3.8 5.7 1 8.8 3 324 11 323 165 -0.5 0 -0.3 -0.8 11/02/2006 07:10:00 5.8 0.8 8.8 3.8 5.9 0.8 8.8 3.8 5.4 1.1 8.4 2.3 317 17 347 165 -0.3 0 -0.1 -0.5 11/02/2006 07:20:00 7 1.1 9.9 4.6 6.9 1 9.5 4.9 6.6 1.2 10.3 3.8 316 9 312 165 -0.2 0 -0.1 -0.5 11/02/2006 07:30:00 5.7 0.9 8 3.8 5.8 0.8 8 3.8 5.2 0.6 7.6 3 313 12 312 165 -0.3 0 -0.1 -0.5 11/02/2006 07:40:00 6.1 0.8 8.4 4.2 6.2 0.7 8.4 4.6 5.6 0.8 8.8 3.4 315 11 331 165 -0.3 0 -0.1 -0.5 11/02/2006 07:50:00 6.5 0.9 8.8 4.2 6.6 0.9 8.8 4.2 6.2 1.1 8.8 3.4 316 13 302 165 0 0.2 0.4 -0.5 11/02/2006 08:00:00 6.4 0.6 8 4.6 6.5 0.6 8 4.9 5.9 0.7 7.6 4.2 310 11 298 165 0.1 0 0.4 -0.3 11/02/2006 08:10:00 6.6 1 8.8 4.2 6.6 1 8.4 3.8 5.6 1.2 8.8 3 303 8 308 165 0.1 0.1 0.4 -0.1 11/02/2006 08:20:00 6.8 1 9.5 4.2 6.8 1 9.9 4.2 5.9 0.9 8.8 3 307 8 303 165 0.3 0 0.7 0.2 11/02/2006 08:30:00 6.4 1 8.8 2.6 6.4 1 8.8 2.6 5.7 0.8 7.6 3.4 310 12 297 165 0.2 0 0.7 0.2 11/02/2006 08:40:00 7 0.9 9.1 4.2 7 0.9 9.1 4.9 6.2 0.9 8.4 3.8 305 9 302 165 0.4 0 0.7 0.2 11/02/2006 08:50:00 8.3 1 11.1 5.7 8.3 0.9 11.1 4.9 7.4 1.1 9.9 4.6 310 10 303 165 0.4 0 0.9 0.2 11/02/2006 09:00:00 8.1 1.4 11.5 5.3 8 1.3 11.1 5.3 7.3 1.4 11.5 4.6 310 11 304 165 0.5 0 0.9 0.2 11/02/2006 09:10:00 7.9 0.9 10.3 5.3 7.8 0.9 10.7 4.9 7.1 1 9.5 4.6 308 8 310 165 0.5 0 0.9 0.2 11/02/2006 09:20:00 8.1 0.9 11.8 6.5 8 0.8 11.5 6.1 7.5 1 11.1 4.6 311 8 300 165 0.9 0 1.4 0.9 11/02/2006 09:30:00 8.3 1.3 11.8 5.7 8.2 1.2 12.2 6.1 8 1.3 12.2 5.3 318 10 314 165 1.2 0.1 1.6 0.9 11/02/2006 09:40:00 8.9 1.2 12.6 5.3 8.9 1.1 12.2 5.7 7.8 0.9 10.7 5.3 309 7 313 165 1.4 0 1.6 1.4 11/02/2006 09:50:00 9.5 1 11.8 6.5 9.4 1 11.8 6.8 7.9 1 12.6 5.3 305 9 290 165 1.4 0 1.6 1.1 11/02/2006 10:00:00 9.1 1 11.1 6.5 9 1 11.1 6.8 8.2 1.1 11.5 4.9 312 7 303 165 1.4 0.1 1.8 1.1 11/02/2006 10:10:00 9 1.1 11.8 6.1 9 1.1 11.8 6.1 7.5 1 10.3 4.9 305 8 304 165 1.5 0.2 1.8 1.4 11/02/2006 10:20:00 8.8 1.2 11.5 5.7 8.8 1.1 11.1 6.1 7.5 1.1 12.2 4.6 305 9 314 165 1.7 0.1 2.1 1.4 11/02/2006 10:30:00 8.7 0.8 10.7 6.5 8.6 0.8 11.1 6.8 7.4 1 10.3 5.3 308 8 293 165 1.8 0.1 2.3 1.4 11/02/2006 10:40:00 7.8 1 11.5 5.3 7.8 1 11.5 5.7 7 1 10.7 4.6 310 12 290 165 2 0.1 2.3 1.4 11/02/2006 10:50:00 7.9 0.7 10.3 6.1 7.8 0.7 9.9 6.1 7 0.8 9.5 4.9 310 8 322 165 2 0.1 2.3 1.6 11/02/2006 11:00:00 8.5 0.9 11.1 6.1 8.4 0.9 11.1 6.1 7.7 0.9 10.3 5.3 311 7 312 165 2 0.1 2.6 1.6 11/02/2006 11:10:00 8.5 1 12.2 5.7 8.5 1 11.8 5.7 7.5 1 10.7 5.3 308 8 302 165 2.2 0 2.6 1.8 11/02/2006 11:20:00 8.6 1 10.7 5.3 8.6 1 11.1 5.7 7.4 1 10.7 4.6 308 6 305 165 2.1 0 2.6 1.8 11/02/2006 11:30:00 8.5 1.1 11.8 5.7 8.4 1.1 11.5 5.3 7.6 0.9 9.9 5.3 308 9 298 165 2.2 0.1 2.8 1.6 11/02/2006 11:40:00 7.7 1 10.3 4.9 7.7 0.9 10.3 5.3 7.1 1 10.7 4.6 310 9 292 165 2.2 0 2.6 1.8 11/02/2006 11:50:00 8.3 1.2 11.5 4.9 8.2 1.2 11.1 4.9 7.5 1 10.7 4.9 310 11 304 165 2.3 0 2.6 1.6 11/02/2006 12:00:00 7.5 0.9 10.3 4.9 7.5 0.9 10.3 5.3 7 1 9.9 4.2 317 13 306 165 2.7 0.3 3.3 2.3 11/02/2006 12:10:00 7.1 1 9.5 4.6 7 0.9 9.5 4.9 6.9 1 9.1 4.6 328 16 349 165 3.3 0 3.5 3 11/02/2006 12:20:00 7.7 0.8 9.9 5.7 7.7 0.8 9.9 5.7 7.3 0.8 9.1 4.6 317 11 305 165 3.2 0.2 3.8 2.8 11/02/2006 12:30:00 8 1.1 10.3 4.9 7.8 1 10.3 4.9 7.6 1 10.3 4.6 323 14 316 165 3.1 0 3.3 2.8 11/02/2006 12:40:00 8.5 1.4 11.8 4.9 8.4 1.3 11.8 5.3 7.7 1.3 10.7 3.8 312 12 300 165 3 0.1 3.3 2.8 11/02/2006 12:50:00 8.9 0.8 11.8 6.8 8.8 0.9 12.2 6.5 7.6 1 10.7 4.9 307 9 296 165 2.6 0.1 3 2.3 11/02/2006 13:00:00 9.8 1 11.8 6.5 9.7 1 11.8 6.8 7.8 1 10.7 5.3 304 7 302 165 2.4 0 2.8 2.3 11/02/2006 13:10:00 9 1.2 13.3 6.1 8.9 1.1 13 6.1 7.4 1.1 11.5 5.3 303 9 292 165 2.7 0.1 3.5 2.6 11/02/2006 13:20:00 7.7 1 10.3 4.9 7.6 1 10.3 4.9 7 1 9.9 4.6 318 17 303 165 2.7 0.1 3 2.6 11/02/2006 13:30:00 7.9 1 10.3 5.3 7.8 1 10.3 5.3 7.7 1 9.9 4.9 332 15 350 165 2.8 0 3.3 2.6 11/02/2006 13:40:00 9.4 1 12.2 6.5 9.3 1 11.8 6.8 7.6 0.9 9.9 4.9 303 8 300 165 2.7 0.2 3.3 2.6 11/02/2006 13:50:00 8.8 1 11.5 5.7 8.6 1 11.5 5.3 7.6 0.9 10.3 5.3 307 8 296 165 3 0 3.3 2.8 11/02/2006 14:00:00 8.2 0.8 10.7 6.1 8.1 0.7 10.7 6.5 7.6 0.8 9.1 5.3 317 13 298 165 3 0.1 3.5 2.8 11/02/2006 14:10:00 8.4 1 10.7 6.1 8.4 1 10.7 6.1 8 1.1 10.7 5.7 320 12 325 165 2.7 0 3 2.6 11/02/2006 14:20:00 8.4 0.9 10.7 5.7 8.2 0.9 10.3 5.7 7.7 0.9 10.3 5.7 315 9 309 165 3 0 3.3 2.8 11/02/2006 14:30:00 7.9 1 10.7 5.3 7.8 1 9.9 4.9 7.2 0.8 9.5 4.9 316 12 302 165 3.2 0.1 3.5 2.8 11/02/2006 14:40:00 8.9 1.1 11.8 6.1 8.8 1.1 11.5 6.1 7.6 0.8 10.3 5.3 307 9 307 165 2.6 0.1 3 2.3 11/02/2006 14:50:00 10.1 1 12.2 7.2 10 1 11.8 7.2 9.1 1.3 12.2 5.7 314 11 304 165 2.4 0.1 2.8 2.1 11/02/2006 15:00:00 9.9 1.3 14.1 6.8 9.9 1.3 13.7 7.2 8.8 1.2 12.2 6.1 310 9 306 165 2.3 0 2.6 2.1 11/02/2006 15:10:00 10.1 1.2 14.1 7.2 10.1 1.2 13.3 6.8 8.5 1.2 12.2 5.3 305 9 295 165 2.3 0 2.8 2.1 11/02/2006 15:20:00 9.8 1.3 14.1 6.5 9.7 1.3 13.7 6.5 8.2 1 11.5 5.7 301 9 297 165 2.1 0.1 2.6 1.4 11/02/2006 15:30:00 9.6 1.2 12.6 6.5 9.6 1.2 13 6.5 8 1.2 10.7 5.3 302 10 303 165 2 0 2.3 1.6 11/02/2006 15:40:00 9.2 1.3 13.3 5.7 9.1 1.3 13 5.7 8 1 12.2 5.3 307 15 291 165 2.1 0 2.6 1.8 11/02/2006 15:50:00 8.8 1.2 11.8 5.7 8.7 1.1 11.8 6.1 7.8 1.2 11.5 3.8 307 13 303 165 2.3 0 2.8 1.8 11/02/2006 16:00:00 8.9 1.3 12.2 5.7 8.8 1.3 12.2 5.7 7.9 1.3 12.2 5.3 307 15 329 165 2.3 0 2.6 2.1 11/02/2006 16:10:00 8.4 1.1 11.5 5.3 8.4 1.1 11.1 5.7 7.1 0.9 9.9 4.6 300 10 309 165 2 0 2.6 1.8 11/02/2006 16:20:00 7.9 1.3 11.8 4.9 7.8 1.3 11.8 4.9 7.1 1.5 11.8 4.2 313 15 328 165 2 0.1 2.3 1.6 11/02/2006 16:30:00 7.9 1.5 11.5 4.2 7.9 1.4 11.5 4.9 7.1 1.5 10.7 4.2 305 16 296 165 1.9 0 2.3 1.6 11/02/2006 16:40:00 7.1 1.4 11.5 4.6 7.2 1.3 11.1 4.9 6.7 1.1 10.3 4.2 314 10 298 165 1.8 0.1 2.1 1.4 11/02/2006 16:50:00 8.5 1.5 12.2 5.3 8.5 1.5 11.8 5.3 7.3 1.1 9.9 4.6 308 11 301 165 1.7 0.1 1.8 1.4 11/02/2006 17:00:00 8.4 1.2 13 5.3 8.5 1.1 12.6 5.3 7.3 1.2 11.5 4.9 294 13 285 165 1.2 0.1 1.6 0.9 11/02/2006 17:10:00 8.2 1.5 11.8 3.8 8.2 1.5 11.8 4.2 7.4 1.3 10.3 4.2 311 15 296 165 1.2 0.1 1.6 0.7 11/02/2006 17:20:00 7.4 1.1 10.7 4.6 7.5 1.1 10.7 4.9 6.7 1 10.7 4.2 306 10 335 165 1.1 0 1.4 0.9 11/02/2006 17:30:00 7 1.3 10.7 4.2 7.2 1.2 10.3 4.6 6.5 1.1 10.3 3.4 299 15 302 165 1.1 0.1 1.4 0.7 11/02/2006 17:40:00 7.6 1.1 10.7 4.9 7.6 1.1 10.7 4.9 6.9 1.1 10.3 4.2 308 15 319 165 1 0 1.4 0.7 11/02/2006 17:50:00 6.6 1.1 9.9 3.8 6.6 1 9.5 4.2 6 1 9.1 3.8 314 18 300 165 1.1 0 1.4 0.9 11/02/2006 18:00:00 8 1.7 13.3 3.4 8 1.7 12.6 3.4 6.9 1.5 11.1 3.8 303 11 289 165 1.2 0 1.8 0.9 11/02/2006 18:10:00 7 1.5 10.7 4.2 6.9 1.4 10.3 3.8 6.2 1.2 9.1 3.8 311 17 300 165 1.2 0.1 1.4 0.7 11/02/2006 18:20:00 6.1 1.5 10.3 1.9 6.1 1.5 9.5 1.1 5.5 1.6 10.3 2.3 310 15 321 165 1 0 1.4 0.7 11/02/2006 18:30:00 6 1.3 9.1 3 5.9 1.3 9.1 2.6 5.8 1.3 9.5 3 327 17 339 165 1.1 0 1.4 0.9 11/02/2006 18:40:00 7 1.6 11.8 3.4 7.1 1.5 11.1 3.4 6 1.3 9.9 2.6 301 12 298 165 1.2 0.1 1.4 0.9 11/02/2006 18:50:00 6.5 1.9 12.2 2.6 6.5 1.9 11.8 2.3 6.1 1.7 11.1 2.6 317 20 317 165 1.2 0 1.6 1.1 11/02/2006 19:00:00 6.7 1 9.5 4.2 6.7 0.9 9.1 4.2 6.6 1.1 9.5 3.8 324 17 326 165 1.3 0 1.8 1.1 11/02/2006 19:10:00 7 1.3 11.5 4.2 7 1.2 11.5 4.2 6 1.1 9.1 3.8 305 15 283 165 1.2 0 1.6 0.9 11/02/2006 19:20:00 7.7 1.2 11.5 4.6 7.6 1.1 11.5 4.9 6.6 1.1 10.3 3.8 307 11 293 165 1.3 0 1.6 1.1 11/02/2006 19:30:00 6.3 1.3 9.5 3 6.3 1.2 9.5 3 5.2 1.3 9.1 1.5 304 13 317 165 1.2 0 1.4 0.9 11/02/2006 19:40:00 6.2 1.3 9.9 3.8 6.2 1.3 10.3 3.8 5.7 1.1 9.5 3 320 13 311 165 1.1 0 1.6 0.9 11/02/2006 19:50:00 7.1 1 10.7 4.6 7.1 1 10.3 4.6 6.9 1.1 9.9 4.6 320 10 318 165 1.1 0 1.4 0.9 11/02/2006 20:00:00 5.8 1.1 8.8 3.4 5.9 1.1 9.1 3.4 5.8 1.1 8.4 3 331 12 331 165 1 0 1.4 0.9 11/02/2006 20:10:00 6.8 1.3 10.7 4.6 6.7 1.2 10.7 4.6 6.7 1.2 10.7 4.2 327 13 327 165 0.9 0 1.4 0.9 11/02/2006 20:20:00 6.6 1.1 10.7 4.6 6.5 1 10.7 3.4 6.6 1 10.3 4.6 335 13 338 165 0.8 0 1.1 0.7 11/02/2006 20:30:00 6.1 1.1 9.5 4.2 6.1 1.1 10.7 4.2 5.6 0.9 9.1 3 311 18 293 165 0.7 0 0.9 0.4 11/02/2006 20:40:00 5.8 1.2 8.8 3.4 5.8 1.2 8.8 3.4 5.8 1 8 3.4 324 11 321 165 0.7 0 1.4 0.4 11/02/2006 20:50:00 6 0.9 8 4.2 6.1 0.8 8 4.2 6 1 8.4 3.8 320 12 319 165 0.6 0 0.9 0.4 11/02/2006 21:00:00 5.9 0.9 8.4 3.8 5.7 1 8 2.6 5.7 1 8.4 3 328 17 330 165 0.5 0 0.9 0.2 11/02/2006 21:10:00 7 1.1 10.3 3.8 6.7 1.1 9.5 3.8 7 1 9.9 4.6 337 16 353 165 0.5 0 0.9 0.2 11/02/2006 21:20:00 6.8 1.5 11.5 4.2 6.9 1.4 11.5 4.6 6.8 1.5 11.8 3.8 327 10 338 165 0.5 0 0.9 0.2 11/02/2006 21:30:00 7.9 2.1 12.6 3.4 7.6 1.9 12.2 3 7.8 2.2 14.1 3.4 335 15 339 165 0.8 0 0.9 0.7 11/02/2006 21:40:00 7.6 1.9 13 3.8 7.6 2 13.3 3.4 7.5 2 13 3.4 330 15 325 165 0.8 0 0.9 0.7 11/02/2006 21:50:00 8.7 1.9 13 4.2 8.5 1.9 13.3 4.9 8.5 1.8 13.7 4.2 333 14 336 165 0.6 0 0.9 0.4 11/02/2006 22:00:00 7.7 1.7 12.6 3.4 7.1 1.4 11.5 3.4 7.8 1.9 13.3 3 336 16 351 165 0.8 0 0.9 0.7 11/02/2006 22:10:00 7.3 1.7 13.7 4.2 7.3 1.7 13.7 4.6 7.1 1.6 11.8 4.2 326 12 342 165 0.5 0 0.9 0.2 11/02/2006 22:20:00 7.9 1.4 11.8 4.6 8 1.3 11.5 5.3 8 1.5 12.6 4.9 334 11 350 165 0.7 0 0.9 0.4 11/02/2006 22:30:00 8.3 1.4 11.5 5.3 8.2 1.5 11.8 4.2 8.1 1.4 11.5 4.9 334 10 328 165 0.4 0 0.9 0.2 11/02/2006 22:40:00 7.9 1.2 10.7 4.6 7.7 1.3 11.5 3 7.7 1.2 10.3 4.2 338 11 348 165 0.5 0 0.9 0.4 11/02/2006 22:50:00 7.7 2 14.5 3.8 7.4 2.1 14.5 3 7.7 2.1 14.9 2.6 342 15 337 165 0.7 0.1 0.9 0.4 11/02/2006 23:00:00 6 1.7 10.7 2.6 5.7 1.8 10.3 2.6 5.8 1.7 10.7 3 329 16 334 165 0.5 0.1 0.9 0.2 11/02/2006 23:10:00 6.5 1.7 11.5 3.4 6.4 1.7 11.8 3 6.3 1.9 13 3 326 17 342 165 0.6 0 0.9 0.4 11/02/2006 23:20:00 8 2 13.3 3.4 7.9 2.1 11.8 1.9 8 1.9 13.3 3 335 17 336 165 0.7 0.1 0.9 0.4 11/02/2006 23:30:00 7.3 1.6 11.8 3.8 7.2 1.6 11.5 3.4 6.9 1.6 11.5 3.4 325 15 340 165 0.7 0 0.9 0.7 11/02/2006 23:40:00 6 1.9 10.7 0.4 6 2.1 11.1 0.4 5.2 1.7 10.3 0.7 330 18 293 165 0.5 0 0.9 0.4 11/02/2006 23:50:00 7.4 1.8 13.3 1.9 7.4 1.8 13 1.5 6.7 1.8 12.2 0.7 325 17 325 165 0.6 0 0.9 0.4 11/03/2006 00:00:00 7.9 1.8 13 3.8 7.6 1.8 12.6 3.4 7.7 1.7 12.6 3.8 337 16 325 165 0.7 0.1 1.1 0.4 11/03/2006 00:10:00 7.4 1.5 13.3 4.6 7.4 1.5 13.3 3.4 7.5 1.3 12.6 4.9 332 12 322 165 0.8 0 1.1 0.7 11/03/2006 00:20:00 6.6 1.3 10.3 3.8 6.4 1.5 9.9 2.6 6.2 1.3 10.3 3 335 16 325 165 0.7 0 1.1 0.4 11/03/2006 00:30:00 7.9 1.7 12.2 4.6 7.8 1.7 11.8 3.8 7.7 1.7 11.5 3.8 336 12 348 165 0.6 0 0.9 0.4 11/03/2006 00:40:00 7.8 1.3 11.8 4.2 7.8 1.3 11.5 4.6 7.6 1.3 11.5 4.9 332 12 330 165 0.7 0 1.1 0.7 11/03/2006 00:50:00 6.6 1.2 9.9 3.4 6.3 1.5 9.9 2.6 6.1 1.1 9.5 3.4 339 13 353 165 0.5 0 0.9 0.2 11/03/2006 01:00:00 8.1 1.3 11.1 5.3 8 1.4 10.7 3.8 7.6 1.3 9.9 4.6 335 12 344 165 0.3 0 0.7 0.2 11/03/2006 01:10:00 7.2 1.9 11.5 3 7 2.1 11.5 2.3 7.3 1.7 12.2 3.8 338 17 347 165 0.5 0 0.9 0.2 11/03/2006 01:20:00 8.2 1.9 13.3 4.2 8 1.9 13.3 4.6 7.9 1.5 11.8 4.6 332 15 302 165 0.5 0 0.9 0.2 11/03/2006 01:30:00 8.1 1.6 12.6 4.9 7.6 1.5 12.2 3.4 8 1.7 12.6 4.2 337 15 343 165 0.5 0.1 0.9 0.2 11/03/2006 01:40:00 9.7 1.5 13.3 5.3 9.5 1.6 13 5.3 9.4 1.6 13 4.9 333 9 333 165 0.5 0 0.7 0.2 11/03/2006 01:50:00 6.6 1.2 11.1 3.8 6.5 1.3 10.3 3 6.1 1.2 9.5 3.4 331 13 339 165 0.4 0 0.9 0.2 11/03/2006 02:00:00 7 2.4 14.1 3.4 6.8 2.5 14.1 2.3 6.7 2.2 13.7 3.8 332 17 316 165 0.3 0.1 0.7 0.2 11/03/2006 02:10:00 7.3 2 13.3 3.8 7.2 2.1 13 3.4 7.1 1.9 12.6 4.2 333 14 311 165 0.4 0.1 0.7 0.2 11/03/2006 02:20:00 6.8 1.9 11.1 2.6 6.6 2 11.1 1.9 6.6 1.7 11.1 2.6 337 20 324 165 0.4 0 0.7 0.2 11/03/2006 02:30:00 8.7 2.4 16.1 3 8.4 2.5 16.1 3.4 8.3 2.1 13.7 1.9 329 19 326 165 0.5 0 0.9 0.4 11/03/2006 02:40:00 10.8 1.8 15.6 6.1 10.7 1.9 15.6 5.3 10.3 1.9 16.1 6.5 336 9 338 165 0.7 0 0.9 0.4 11/03/2006 02:50:00 10.1 1.6 13.7 4.9 10 1.6 13.7 4.9 9.4 1.5 12.2 4.6 338 9 352 165 0.5 0 0.9 0.2 11/03/2006 03:00:00 10.3 1.7 14.9 4.9 9.9 1.8 14.5 4.9 9.9 1.5 13.3 6.1 338 11 332 165 0.5 0 0.9 0.4 11/03/2006 03:10:00 10.1 2 14.9 5.3 9.7 2.4 14.9 3.8 9.7 2 14.9 5.3 340 13 329 165 0.6 0 0.9 0.4 11/03/2006 03:20:00 11.3 1.9 16.1 6.5 10.9 2.5 15.6 4.6 11.1 2 16.1 5.3 341 13 338 165 0.5 0 0.9 0.4 11/03/2006 03:30:00 12.3 1.7 16.1 8.4 12 1.7 16.8 8.4 11.8 1.7 16.4 7.2 337 10 341 165 0.5 0 0.9 0.2 11/03/2006 03:40:00 11.1 2 16.1 6.1 10.8 2.1 15.3 6.1 10.6 2.1 15.3 4.9 337 11 334 165 0.5 0 0.9 0.2 11/03/2006 03:50:00 10.1 1.8 13.7 4.6 9.8 2.1 14.1 3.8 9.6 1.7 13.7 4.9 332 14 315 165 0.4 0 0.7 0.2 11/03/2006 04:00:00 9.5 2.3 15.6 4.2 9.3 2.4 16.1 3.4 8.7 2.1 15.6 4.2 328 14 319 165 0.4 0 0.9 0.2 11/03/2006 04:10:00 9.3 2 15.6 4.6 9 2 15.6 4.6 8.9 1.9 13.7 4.6 338 12 331 165 0.4 0 0.9 0.2 11/03/2006 04:20:00 9.1 1.5 13 5.3 8.9 1.5 13.3 5.7 9 1.5 12.6 6.1 335 11 348 165 0.5 0 0.9 0.2 11/03/2006 04:30:00 9.9 1.4 13.3 5.7 9.7 1.5 14.1 5.3 9.1 1.4 13 4.9 336 9 345 165 0.4 0 0.9 0.2 11/03/2006 04:40:00 10.5 1.3 14.1 6.1 10.2 1.7 13.7 6.1 9.8 1.6 14.5 6.1 343 8 342 165 0.3 0 0.7 0.2 11/03/2006 04:50:00 10.1 1.5 14.9 6.8 9.6 1.8 14.5 3.8 9.5 1.4 14.1 6.1 338 11 349 165 0.5 0 0.9 0.2 11/03/2006 05:00:00 10 1.7 15.6 5.7 9.4 1.8 15.6 5.3 9.6 1.7 14.5 4.9 339 13 342 165 0.5 0 0.9 0.2 11/03/2006 05:10:00 10.5 1.7 14.9 6.5 10.4 1.8 15.3 5.7 9.9 1.8 14.1 6.1 339 9 339 165 0.4 0 0.9 0.2 11/03/2006 05:20:00 12.8 1.5 16.4 8.4 12.6 1.7 17.6 6.5 12.3 1.7 16.4 8 342 7 349 165 0.4 0 0.9 0.2 11/03/2006 05:30:00 11.2 1.3 16.1 8.4 10.8 1.8 16.1 4.2 10.5 1.4 14.9 6.5 345 11 337 165 0.3 0.1 0.9 0.2 11/03/2006 05:40:00 9 2.2 13 4.9 8.3 2.1 14.1 3 8 2.2 12.6 2.6 345 15 353 165 0.3 0.1 0.7 0.2 11/03/2006 05:50:00 11.9 1.9 16.8 6.8 11.5 2.3 16.4 5.3 11.3 2.1 15.6 4.9 341 10 340 165 0.2 0 0.7 -0.1 11/03/2006 06:00:00 11.9 1.5 15.6 8.4 11.2 1.7 15.6 6.1 11.6 1.8 16.8 5.3 346 8 2 165 0.4 0 0.7 0.2 11/03/2006 06:10:00 11.5 1.8 16.8 5.3 11.3 1.8 17.2 6.5 11.1 1.7 15.6 6.8 333 10 328 165 0.4 0 0.7 0.2 11/03/2006 06:20:00 12.8 1.5 16.1 9.1 12.5 1.7 16.4 5.7 12.6 1.5 16.1 8.8 337 10 338 165 0.4 0 0.9 0.2 11/03/2006 06:30:00 10.8 1.5 14.5 6.8 10.7 1.6 14.5 6.5 9.8 1.7 15.3 5.3 333 11 323 165 0.4 0.1 0.9 0.2 11/03/2006 06:40:00 9.1 1.9 13.7 4.6 8.8 1.8 13.3 4.2 8.3 1.7 13 3.8 334 15 350 165 0.2 0 0.7 -0.1 11/03/2006 06:50:00 11 2.2 16.8 6.1 10.7 2.4 16.4 4.9 10.4 2.2 16.4 5.3 333 13 333 165 0.3 0 0.7 0.2 11/03/2006 07:00:00 9.4 3.2 17.6 4.2 9.3 3.3 17.6 3.4 9.3 3.2 19.9 4.9 337 11 325 165 0.4 0.1 0.7 0.2 11/03/2006 07:10:00 10.5 2 15.6 5.3 10.4 2 15.6 6.1 10 2.2 15.6 4.6 334 10 336 165 0.2 0 0.7 0.2 11/03/2006 07:20:00 10.6 1.7 16.1 6.5 10.4 1.8 16.1 5.7 10.4 1.9 15.6 5.7 335 11 340 165 0.4 0 0.7 0.2 11/03/2006 07:30:00 9.9 1.6 14.5 6.5 9.7 1.7 14.1 5.3 9.7 1.5 14.9 6.5 332 15 319 165 0.4 0 0.7 0.2 11/03/2006 07:40:00 11.3 1.7 16.1 6.5 10.8 1.8 14.5 4.6 11.1 1.7 16.4 5.7 341 15 5 165 0.1 0 0.4 -0.1 11/03/2006 07:50:00 11.7 1.7 16.8 6.1 11.6 2 16.4 6.1 11.8 1.9 16.4 7.2 333 13 321 165 0.3 0 0.7 0.2 11/03/2006 08:00:00 10.9 2.3 15.6 5.7 10.9 2.2 14.9 5.7 10.7 2.1 16.1 6.8 332 11 329 165 0.2 0 0.7 -0.1 11/03/2006 08:10:00 9.3 1.4 14.1 5.7 9.1 1.4 14.1 4.9 8.9 1.4 14.5 5.7 333 12 334 165 0.1 0 0.2 -0.1 11/03/2006 08:20:00 9.8 1.6 14.5 6.1 9.6 1.7 14.5 4.6 8.9 1.7 14.1 4.2 330 17 328 165 0.1 0 0.7 -0.1 11/03/2006 08:30:00 11.3 2 16.8 6.5 11.2 2.1 16.8 6.1 10.5 2.1 17.9 5.7 334 11 331 165 0.2 0 0.7 -0.1 11/03/2006 08:40:00 11.1 2 15.3 6.5 10.7 2.2 15.6 5.3 10.2 2.1 14.9 5.3 335 13 336 165 0.4 0 0.7 0.2 11/03/2006 08:50:00 11.7 1.6 16.4 6.1 11.6 1.6 16.4 6.8 10.9 1.7 15.6 6.8 334 10 343 165 0.7 0 0.9 0.4 11/03/2006 09:00:00 10.5 1.7 14.9 6.1 10.3 1.9 14.9 6.1 9.6 1.7 14.1 5.3 341 9 344 165 0.8 0 1.1 0.7 11/03/2006 09:10:00 10.1 2.2 15.3 3.8 9.3 2.6 15.3 4.2 10 2 14.9 4.6 343 18 339 165 1.1 0 1.4 0.9 11/03/2006 09:20:00 7.1 1.9 13.3 3 6.9 1.9 13 3 6.6 1.9 13 1.9 336 17 341 165 1.3 0 1.6 1.1 11/03/2006 09:30:00 10.2 2.2 16.8 4.6 10.1 2.2 16.8 4.6 9.5 1.9 14.5 5.3 333 11 330 165 1.4 0 1.6 1.4 11/03/2006 09:40:00 8 2.3 15.3 3.8 7.8 2.4 14.5 3 7 2.4 13 1.1 331 16 341 165 1.6 0 1.8 1.4 11/03/2006 09:50:00 7.7 2.4 13.3 3 7.6 2.5 13.7 3 7 2.5 13.3 1.1 329 17 338 165 1.5 0 1.8 1.4 11/03/2006 10:00:00 8.2 1.8 12.2 4.2 8 1.8 11.8 3.4 7.5 2.2 11.5 2.3 333 13 334 165 1.9 0.1 2.3 1.6 11/03/2006 10:10:00 9.1 1.7 13.3 4.6 9 1.7 13.7 4.2 7.9 1.8 12.6 2.3 331 14 310 165 2 0 2.3 1.6 11/03/2006 10:20:00 8.4 2 13 1.9 8.3 2 12.2 0.7 6.7 2.2 11.1 1.5 324 15 321 165 2 0.1 2.6 1.6 11/03/2006 10:30:00 9.2 2.1 14.5 5.3 8.9 2.3 14.1 4.6 8.1 2 13.7 3.8 334 17 327 165 1.6 0.2 2.3 0.9 11/03/2006 10:40:00 9.6 2.2 16.8 5.3 8.5 2.1 14.9 3.8 9 2.2 14.9 4.9 353 19 19 165 1.5 0.2 1.8 0.9 11/03/2006 10:50:00 10.5 1.3 14.5 6.8 8.7 1.6 14.1 4.6 9.9 1.4 13.7 5.3 2 12 2 165 1.9 0.2 2.6 1.4 11/03/2006 11:00:00 8 2 11.8 3 7.3 1.9 11.1 2.3 7.2 2 11.5 2.3 347 17 354 165 2.3 0.2 2.8 1.6 11/03/2006 11:10:00 7.4 1.4 11.5 3.8 6.6 1.5 10.7 3.4 7 1.2 10.3 4.2 348 14 354 165 2 0.4 2.8 1.4 11/03/2006 11:20:00 8.1 1.5 11.8 3.4 7.9 1.5 11.8 3.8 7.2 1.7 11.8 3 330 17 339 165 2.5 0.3 3 1.6 11/03/2006 11:30:00 7.5 1.7 12.6 4.2 7.3 1.8 12.6 2.6 7.2 1.5 11.5 4.2 333 15 313 165 2.3 0.2 2.8 1.6 11/03/2006 11:40:00 7.2 1.5 12.2 3.4 7.2 1.5 11.5 3 6 1.9 10.3 1.1 323 17 334 165 2.4 0.1 2.8 1.8 11/03/2006 11:50:00 7.8 2.6 14.1 2.6 7.8 2.6 14.1 2.6 7.1 3.1 13.7 1.1 329 16 335 165 2.6 0.2 3 1.6 11/03/2006 12:00:00 10.7 1.7 14.1 5.3 10.6 1.7 13.7 5.3 10.5 1.7 13.3 5.3 339 8 329 165 1.8 0.1 2.3 1.4 11/03/2006 12:10:00 10.7 1.3 14.1 6.1 10.5 1.5 13.7 4.9 10.3 1.3 14.1 6.8 335 9 335 165 1.7 0 1.8 1.4 11/03/2006 12:20:00 10.8 1.6 16.1 6.5 9.7 2.2 14.9 4.9 10.5 1.7 14.9 5.7 340 15 2 165 1.9 0.1 2.3 1.4 11/03/2006 12:30:00 9.5 1.4 14.1 4.9 9.4 1.5 14.9 3.4 9.1 1.5 14.1 4.2 337 8 347 165 2.4 0.1 2.8 1.8 11/03/2006 12:40:00 10 1.4 13.7 5.7 9.9 1.5 13 4.6 9.6 1.3 13 5.3 336 9 336 165 1.9 0.1 2.3 1.4 11/03/2006 12:50:00 10 1.5 13.3 6.1 9.9 1.6 14.1 6.1 9.8 1.5 13 6.5 332 11 347 165 1.9 0 2.1 1.6 11/03/2006 13:00:00 9.9 1.7 13.7 4.6 9.9 1.7 14.1 4.9 9.4 1.9 14.1 4.2 325 15 344 165 2 0 2.3 1.8 11/03/2006 13:10:00 10 2.3 15.6 4.9 9.6 2.5 16.4 4.2 9.7 2.1 16.1 4.9 332 16 327 165 1.9 0 2.3 1.8 11/03/2006 13:20:00 8.6 2.7 14.5 2.6 8.5 2.7 14.1 1.9 8 2.5 13.7 2.6 326 19 321 165 2.5 0.3 3.3 1.8 11/03/2006 13:30:00 6.3 1.5 10.7 1.5 6.2 1.6 10.3 1.5 5.8 1.3 9.5 2.3 326 17 348 165 3 0.3 3.5 2.3 11/03/2006 13:40:00 7.4 1.7 11.5 3.4 7.2 1.9 11.5 2.6 6.7 1.4 10.7 3 327 22 289 165 2.2 0.2 2.8 1.8 11/03/2006 13:50:00 7.5 1.5 11.5 4.9 7.6 1.4 11.8 4.9 6.9 1.5 11.8 4.2 320 10 297 165 2.6 0.4 3.5 1.8 11/03/2006 14:00:00 9.5 1.9 14.5 5.3 9.4 1.8 14.5 5.3 9.2 2 14.9 4.9 323 11 337 165 2.7 0.3 3.5 1.8 11/03/2006 14:10:00 8.9 1.6 13.3 5.3 8.8 1.6 13 5.3 8.6 1.6 13 4.6 326 14 323 165 2.1 0.1 2.6 1.8 11/03/2006 14:20:00 9.4 1.8 13.3 4.6 9.3 1.9 13.7 3.8 9 1.7 13.3 4.9 330 12 341 165 2.4 0.3 3 1.8 11/03/2006 14:30:00 10.2 2.3 14.9 4.2 10.1 2.2 15.3 4.6 9.6 2.2 14.1 3.4 324 13 324 165 2.6 0.1 2.8 1.8 11/03/2006 14:40:00 8.8 1.8 13.7 4.2 8.7 1.8 13.3 3.8 8.2 1.8 12.6 3.8 327 13 315 165 3.1 0.2 3.5 2.3 11/03/2006 14:50:00 12 2.7 16.8 4.6 11.9 2.6 16.4 4.2 11.4 2.7 16.8 4.2 332 10 327 165 2.8 0 3 2.6 11/03/2006 15:00:00 11.6 2.5 19.1 5.7 11.4 2.5 19.5 5.7 11 2.4 19.9 6.1 334 9 318 165 2.7 0 3 2.6 11/03/2006 15:10:00 10.8 2.1 16.8 7.2 10.7 2 16.4 5.7 10.3 2.2 16.4 4.6 329 13 330 165 2.7 0 2.8 2.6 11/03/2006 15:20:00 9.9 1.5 13.7 5.7 9.8 1.5 13.7 5.7 9.4 1.5 13.7 5.7 328 10 326 165 2.7 0 3 2.3 11/03/2006 15:30:00 10.5 1.4 13.7 5.7 10.3 1.3 13.3 5.3 9.6 1.5 13.3 4.9 326 10 325 165 2.7 0.1 3 2.3 11/03/2006 15:40:00 10.2 1.5 14.5 5.7 10.1 1.5 14.9 5.7 9.7 1.5 13.7 6.1 327 9 325 165 2.4 0 2.6 2.1 11/03/2006 15:50:00 11.9 2.2 17.2 6.1 11.7 2.1 16.4 6.1 11 2.2 15.6 4.9 331 10 324 165 2.4 0 2.6 2.1 11/03/2006 16:00:00 10.9 2.1 16.1 6.8 10.8 2.1 16.1 6.1 10.2 2 14.9 5.3 333 11 315 165 2.3 0 2.6 1.8 11/03/2006 16:10:00 10.8 1.7 15.6 5.7 10.8 1.7 15.6 6.5 10.3 1.7 14.9 5.7 328 10 348 165 1.7 0.2 2.6 0.9 11/03/2006 16:20:00 11 1.6 15.3 6.1 10.9 1.6 14.9 6.1 10.3 1.7 14.5 5.7 334 10 334 165 1.5 0.1 1.8 0.9 11/03/2006 16:30:00 10.1 1.5 14.1 5.7 10.1 1.5 13.7 6.1 9.3 1.7 13.3 4.9 329 10 325 165 1.6 0 1.8 0.9 11/03/2006 16:40:00 9.1 2 14.1 4.9 9.1 1.9 14.1 4.9 8.8 1.8 13.3 4.2 330 11 332 165 1.5 0 1.8 1.4 11/03/2006 16:50:00 6.5 1.4 11.1 2.3 6.6 1.3 11.1 3 5.8 1.6 9.9 0.4 326 12 325 165 1.2 0.1 1.8 0.9 11/03/2006 17:00:00 5.6 1.1 8.4 2.6 5.3 1.2 8 1.9 5.3 1.2 7.6 2.3 340 19 327 165 0.7 0 1.4 0.4 11/03/2006 17:10:00 6.1 1.2 9.9 3 5.4 1.3 8.4 2.3 5.8 1.3 10.3 2.6 349 14 8 165 0.4 0.1 0.9 0.2 11/03/2006 17:20:00 6 1.1 9.5 3.4 5.2 1.1 8.8 2.3 5.9 1.2 9.5 3.4 354 15 7 165 0.3 0.1 0.7 0.2 11/03/2006 17:30:00 5.8 1.4 9.5 2.6 5.4 1.4 9.1 2.6 5.3 1.2 9.1 3 340 17 321 165 0.1 0 0.7 -0.1 11/03/2006 17:40:00 8.9 2.1 14.5 3.8 8.8 2.1 14.5 3.4 8.2 2.4 14.5 1.5 334 11 325 165 0.4 0.1 0.9 0.2 11/03/2006 17:50:00 8.7 1.5 14.5 6.1 8.2 1.6 12.6 4.6 8.2 1.6 13.3 4.2 344 21 12 165 0.5 0 0.9 0.2 11/03/2006 18:00:00 9.6 1.5 14.1 5.3 9.5 1.5 13.7 5.3 8.8 1.5 13 4.6 327 12 333 165 0.7 0 0.9 0.7 11/03/2006 18:10:00 8.6 1.6 13 3.8 8.4 1.7 13 3.4 7.9 1.5 12.2 3.4 335 22 325 165 0.7 0 0.9 0.4 11/03/2006 18:20:00 8.7 1.5 12.6 4.6 7.2 1.7 11.8 3.4 8.4 1.5 12.2 4.6 8 12 34 165 0.6 0 0.9 0.4 11/03/2006 18:30:00 7.6 1.2 11.5 4.9 6.7 1.3 10.7 3.4 7.4 1.1 11.5 4.9 355 16 16 165 0.4 0.2 0.9 0.2 11/03/2006 18:40:00 7.8 1.2 10.7 4.6 7.4 1.5 11.5 3.4 7.9 1 10.7 4.9 344 12 347 165 0.3 0.1 0.7 0.2 11/03/2006 18:50:00 7.6 1.1 11.1 4.9 6.2 1.5 10.7 3 7.8 1.1 11.5 5.3 358 14 12 165 0.2 0.1 0.7 0.2 11/03/2006 19:00:00 8.1 1.7 13.7 4.2 6.8 1.7 11.5 2.6 8 1.9 13.3 3.4 2 15 2 165 0.3 0.1 0.7 0.2 11/03/2006 19:10:00 7.1 1 9.9 3.8 6.4 1.3 10.3 3.4 7.2 1 9.9 4.9 350 11 358 165 0.4 0.2 0.9 0.2 11/03/2006 19:20:00 7.9 1.3 12.6 4.2 6.9 1.6 10.3 3.4 7.9 1.2 11.5 4.6 350 15 357 165 0.1 0.1 0.7 -0.1 11/03/2006 19:30:00 7.4 1.1 9.9 4.9 6.2 1.5 9.9 3.4 7.3 1.1 9.9 4.6 358 13 18 165 0.4 0.1 0.7 0.2 11/03/2006 19:40:00 6.4 1.2 10.7 3.8 6.3 1.2 10.7 3.4 6.1 1 9.5 3.8 331 13 316 165 0.1 0 0.2 -0.1 11/03/2006 19:50:00 7.4 1.3 12.2 4.9 7.3 1.3 11.5 4.9 7.3 1.1 10.7 4.9 331 11 317 165 0.1 0 0.7 -0.1 11/03/2006 20:00:00 6.1 1.1 9.5 3.4 6 1.1 9.5 3 6.1 0.9 8.8 3.4 336 10 328 165 0.1 0 0.7 -0.1 11/03/2006 20:10:00 6.6 1.1 9.5 3.8 6.6 1.2 9.5 3.4 6.5 1.1 9.9 4.6 333 11 337 165 0 0.1 0.7 -0.3 11/03/2006 20:20:00 4.9 1.1 8.4 3 4.6 1.1 8 1.9 5.1 1.1 8.8 3 343 9 359 165 0.2 0.2 0.9 -0.3 11/03/2006 20:30:00 4 0.8 6.5 2.6 3.7 1 6.5 1.5 4.2 0.6 6.1 2.6 339 17 339 165 -0.2 0 0.2 -0.3 11/03/2006 20:40:00 6.1 1.7 10.7 3 6 1.7 10.7 3 6 1.7 9.5 2.3 331 11 339 165 -0.2 0.2 0.2 -0.5 11/03/2006 20:50:00 7.1 1.3 10.3 4.2 6.8 1.5 10.3 2.3 6.8 1.3 10.3 3 338 12 322 165 0.2 0 0.4 -0.1 11/03/2006 21:00:00 7.4 1.5 11.1 3.8 7.3 1.5 11.1 4.2 7.5 1.5 11.5 4.2 337 11 332 165 0.2 0 0.7 0.2 11/03/2006 21:10:00 6.4 0.8 8.8 3.4 6.4 0.9 9.1 3 6.4 1 8.4 3.8 334 9 339 165 0.1 0 0.4 -0.1 11/03/2006 21:20:00 6.9 1.3 10.3 3.8 6.9 1.3 9.9 3.8 6.6 1.3 9.9 3.8 333 9 348 165 -0.1 0 0.4 -0.1 11/03/2006 21:30:00 9.1 1.5 13 5.3 8.6 1.9 12.6 3.4 8.8 1.3 12.2 5.3 341 10 338 165 0.1 0 0.2 -0.1 11/03/2006 21:40:00 8.5 1.5 12.2 4.9 8.1 1.7 12.2 3.4 8.3 1.3 13 4.2 340 13 341 165 0.2 0 0.7 -0.1 11/03/2006 21:50:00 8.7 1.7 14.5 5.3 8.8 1.7 14.5 6.1 8.8 1.7 14.5 5.3 338 8 334 165 0.2 0 0.7 -0.1 11/03/2006 22:00:00 9.5 1.3 12.6 6.1 9.4 1.4 13.3 5.7 9.3 1.3 12.6 5.7 339 9 341 165 0.2 0 0.7 -0.1 11/03/2006 22:10:00 9 1.7 13 3.8 8.8 1.7 12.2 4.2 9 1.6 13 4.9 335 11 325 165 0.3 0 0.7 0.2 11/03/2006 22:20:00 8.1 1.6 11.8 4.6 8 1.6 12.6 3.8 7.5 1.4 12.2 4.6 340 9 349 165 0.1 0 0.7 -0.1 11/03/2006 22:30:00 9.1 1.5 12.6 5.3 8.9 1.5 12.2 3.8 8.6 1.3 12.2 5.7 339 9 326 165 0.1 0 0.4 -0.1 11/03/2006 22:40:00 7 1.9 11.1 3.8 6.9 2 11.1 2.3 6.9 2 11.5 3.8 341 9 327 165 0.2 0 0.7 -0.1 11/03/2006 22:50:00 8.4 1.9 11.8 3.4 8.2 2.2 11.8 2.3 7.9 1.9 11.5 3.4 337 12 340 165 -0.1 0 0.2 -0.3 11/03/2006 23:00:00 8.7 1.2 11.8 4.9 8.6 1.3 11.8 5.3 8.5 1.2 11.5 4.6 338 8 339 165 0.1 0 0.4 -0.1 11/03/2006 23:10:00 9.8 1.3 13.3 6.5 9 2 14.1 4.6 9.9 1.4 14.1 6.5 347 12 348 165 0.2 0 0.7 -0.1 11/03/2006 23:20:00 9.8 1.9 15.3 4.6 9.8 2 14.9 3.8 9.8 1.9 14.9 6.5 337 10 349 165 0.3 0.1 0.9 0.2 11/03/2006 23:30:00 10.4 1.5 13.3 6.8 10.2 1.6 13.3 6.5 10.2 1.5 15.3 6.5 339 9 330 165 0.2 0 0.4 -0.1 11/03/2006 23:40:00 9.4 1.4 13.3 5.3 9.2 1.6 13.3 4.9 9.3 1.4 12.6 6.1 339 10 346 165 0.2 0 0.2 -0.1 11/03/2006 23:50:00 8 1.5 11.1 4.2 7.8 1.7 11.5 3 7.7 1.5 13 4.9 340 10 344 165 0.1 0 0.4 -0.1 11/04/2006 00:00:00 8.8 1 11.1 6.5 8.7 1 11.1 5.7 8.5 1 11.5 6.1 342 7 351 165 -0.1 0 0.2 -0.1 11/04/2006 00:10:00 7 1.5 11.1 4.2 7 1.5 11.5 4.6 7 1.4 11.8 4.6 332 9 327 165 -0.3 0.1 0.2 -0.5 11/04/2006 00:20:00 7.2 1.1 10.7 4.9 7 1.1 11.5 4.6 7.1 1.2 11.8 4.2 338 12 352 165 -0.3 0 -0.1 -0.5 11/04/2006 00:30:00 7 0.8 9.5 4.9 7 0.8 9.1 4.6 6.9 0.7 9.1 4.9 326 10 318 165 -0.6 0 -0.1 -0.8 11/04/2006 00:40:00 7 1.1 9.9 4.6 7 1 9.5 4.9 6.4 0.9 9.5 4.6 314 11 320 165 -0.5 0.1 -0.1 -0.8 11/04/2006 00:50:00 6.1 0.9 8.8 3.4 6.1 0.8 8.4 3.4 5.9 0.9 8 3 323 10 323 165 -0.5 0.1 -0.1 -0.8 11/04/2006 01:00:00 7.5 1 9.9 4.9 7.4 1 9.5 4.9 6.8 1 9.5 4.6 320 9 324 165 -0.7 0 -0.5 -1 11/04/2006 01:10:00 8.1 1.2 11.8 5.3 8 1.2 12.2 5.3 7.5 1.1 11.5 4.9 324 15 311 165 -0.4 0.2 -0.1 -0.8 11/04/2006 01:20:00 9 1.1 12.6 6.5 9 1.1 13 6.1 8.7 1.2 11.5 5.7 337 8 320 165 -0.3 0 -0.1 -0.5 11/04/2006 01:30:00 8.1 1.3 11.8 5.7 7.9 1.2 11.1 5.3 8 1.5 11.5 4.9 330 11 356 165 -0.1 0 0.2 -0.3 11/04/2006 01:40:00 9.3 1.3 13 6.5 9.2 1.3 13.3 5.7 9.1 1.2 12.6 6.1 338 8 329 165 -0.2 0 0.2 -0.5 11/04/2006 01:50:00 8.1 1.1 12.2 5.7 7.8 1.3 12.2 4.2 8.1 1.1 12.6 5.3 339 10 342 165 0.1 0 0.4 -0.1 11/04/2006 02:00:00 8.7 1.1 11.8 5.7 8.6 1 11.8 6.1 8.5 1.1 11.5 6.5 331 8 330 165 -0.1 0 0.4 -0.3 11/04/2006 02:10:00 8.3 1.2 11.5 4.6 8.2 1.1 11.5 4.9 7.9 1.3 11.1 4.2 325 13 342 165 -0.3 0.1 0.2 -0.5 11/04/2006 02:20:00 6.5 1.2 9.9 4.2 6.5 1.1 9.9 3.8 6.3 1.1 9.9 4.2 326 11 304 165 -0.3 0 -0.1 -0.5 11/04/2006 02:30:00 6.2 1.3 9.9 2.6 6 1.6 10.3 1.9 6.1 1.3 9.5 3 336 14 323 165 0 0.1 0.2 -0.5 11/04/2006 02:40:00 5.2 1 8 3 5.2 1 8 3 4.9 0.9 7.2 2.6 319 10 319 165 -0.2 0 0.2 -0.5 11/04/2006 02:50:00 6.3 1.5 11.1 3 6.1 1.5 11.5 2.6 6.1 1.6 11.5 3.4 330 15 339 165 -0.3 0.1 -0.1 -0.5 11/04/2006 03:00:00 8.5 1.3 13.7 5.7 8.4 1.3 13 4.6 8.4 1.2 13.7 5.3 337 9 335 165 0 0.1 0.2 -0.5 11/04/2006 03:10:00 9.7 1.2 13.7 6.5 9.3 1.6 13 4.6 9.6 1.2 13 6.8 342 10 350 165 0 0 0.2 -0.1 11/04/2006 03:20:00 9.2 1.7 13.3 4.6 9 1.9 13.3 4.2 8.7 1.9 12.6 4.9 336 10 339 165 0.1 0 0.4 -0.1 11/04/2006 03:30:00 8.3 1 11.5 5.7 8.1 1.1 11.1 4.9 7.9 0.9 10.7 6.1 340 10 339 165 -0.1 0 0.2 -0.3 11/04/2006 03:40:00 6.1 1.2 10.7 3.8 6 1.3 11.1 2.6 5.8 1.3 10.3 3 335 11 323 165 -0.1 0.1 0.2 -0.3 11/04/2006 03:50:00 7.1 1.7 12.2 3.8 6.8 1.8 12.6 3 7 1.7 13.3 4.2 342 11 351 165 -0.3 0 -0.1 -0.5 11/04/2006 04:00:00 8.4 1.7 13.7 3.8 8 1.8 13.7 2.6 8.3 1.7 13.7 4.9 338 13 326 165 -0.1 0 0.2 -0.1 11/04/2006 04:10:00 9.9 1.8 14.9 4.6 9.7 1.9 14.1 4.2 9.6 1.5 14.9 6.5 335 10 349 165 0 0 0.2 -0.1 11/04/2006 04:20:00 8.6 1.3 11.1 4.6 8.4 1.3 11.5 4.2 8.4 1.3 11.5 4.6 338 11 319 165 -0.1 0 0.4 -0.1 11/04/2006 04:30:00 9.6 1.9 14.1 5.3 9.2 2 13 4.6 9.3 2 13.7 4.6 343 11 352 165 -0.1 0 0.2 -0.1 11/04/2006 04:40:00 8.3 1.4 12.6 4.9 7.8 1.7 12.6 3.8 7.7 1.5 13 3.8 341 14 344 165 -0.2 0.1 0.2 -0.5 11/04/2006 04:50:00 8 1.3 12.2 4.6 7.8 1.3 12.6 4.2 7.6 1.5 13 4.6 336 10 347 165 -0.3 0 -0.1 -0.5 11/04/2006 05:00:00 8.5 1.2 11.5 3.8 8.4 1.2 11.5 4.2 8.2 1.3 11.8 4.6 330 8 328 165 -0.3 0 -0.1 -0.5 11/04/2006 05:10:00 9.6 1.3 13 5.7 9.5 1.2 13.3 6.5 9.4 1.3 12.2 6.5 334 10 341 165 -0.3 0 0.2 -0.5 11/04/2006 05:20:00 10 1.5 14.1 6.1 9.9 1.5 14.5 6.1 9.7 1.5 13.7 6.5 331 10 344 165 -0.2 0 0.2 -0.5 11/04/2006 05:30:00 10.1 1.8 15.3 5.7 9.9 1.8 14.5 5.3 9.5 1.7 14.9 5.7 338 9 327 165 -0.3 0.1 0.2 -0.5 11/04/2006 05:40:00 10.6 1.7 17.2 7.2 10.4 1.7 17.9 4.6 10.3 1.7 16.8 6.8 336 11 348 165 -0.2 0 0.2 -0.3 11/04/2006 05:50:00 9.4 1.5 13.3 5.3 9.2 1.5 13.3 4.9 9 1.3 13 5.7 333 11 339 165 -0.3 0 0.2 -0.5 11/04/2006 06:00:00 8.4 1.9 13.3 2.6 8.3 2 13 3 8.3 2 13.3 2.6 332 12 339 165 -0.2 0 -0.1 -0.3 11/04/2006 06:10:00 8.2 1.8 12.2 4.6 7.9 1.8 12.2 3.8 7.9 1.6 11.5 4.6 330 15 307 165 -0.1 0 0.2 -0.3 11/04/2006 06:20:00 7.9 2.2 13.7 4.6 7.8 2.1 14.1 4.6 7.8 2 13.3 4.2 332 12 332 165 -0.2 0.1 0.2 -0.5 11/04/2006 06:30:00 9.7 1.6 14.1 6.1 9.4 1.6 14.1 5.3 9.3 1.6 14.5 5.3 335 12 357 165 -0.1 0.1 0.2 -0.3 11/04/2006 06:40:00 10 1.6 14.5 6.1 9.8 1.7 14.5 5.7 9.4 1.5 13.7 4.6 339 9 339 165 -0.3 0 -0.1 -0.3 11/04/2006 06:50:00 10.4 2.1 14.9 4.9 10.4 2.1 15.6 4.9 9.9 2.1 15.3 4.6 331 12 342 165 -0.2 0 0.2 -0.3 11/04/2006 07:00:00 10.5 1.6 15.3 6.8 10.1 1.8 14.9 5.7 10 1.5 13.7 6.5 332 14 343 165 -0.2 0 0.2 -0.3 11/04/2006 07:10:00 9.4 1.8 14.1 4.2 9.3 1.9 14.5 4.2 8.5 2 13 3.4 332 13 348 165 -0.3 0 0.2 -0.5 11/04/2006 07:20:00 8.7 1.6 14.1 5.7 8.5 1.7 14.5 3.4 7.7 1.7 14.1 3.4 339 11 347 165 -0.3 0 -0.1 -0.5 11/04/2006 07:30:00 8 2 13.7 3.4 7.5 2 13.3 3 7.2 2 13.7 2.6 340 18 326 165 -0.5 0 -0.1 -0.8 11/04/2006 07:40:00 10.1 1.9 16.1 5.7 9.5 1.9 14.5 4.9 9.4 2.1 14.1 4.6 342 12 356 165 -0.3 0 -0.1 -0.5 11/04/2006 07:50:00 8.4 2.1 14.1 3.8 8.1 2 13 4.2 7.9 2.1 14.5 4.2 335 16 358 165 -0.4 0 -0.1 -0.5 11/04/2006 08:00:00 9.3 2.3 15.3 4.6 9 2.3 15.3 4.9 8.7 2.5 15.3 3.8 332 15 349 165 -0.3 0 0.2 -0.5 11/04/2006 08:10:00 10.4 2.2 15.3 4.6 9.8 2.3 15.3 4.2 9.8 2.2 15.3 4.6 338 15 344 165 -0.2 0 0.2 -0.3 11/04/2006 08:20:00 9.9 2.1 14.5 5.3 9.7 2.3 14.5 4.9 9.7 2.1 14.9 4.9 338 11 341 165 -0.2 0 0.2 -0.3 11/04/2006 08:30:00 9.5 1.7 13.7 6.1 9.1 1.9 13.7 4.6 8.9 1.7 12.6 4.9 338 13 338 165 -0.2 0 0.2 -0.3 11/04/2006 08:40:00 9.9 2.3 14.9 4.2 9.5 2.2 15.3 4.2 9.2 2.3 13.7 3.8 332 15 351 165 -0.1 0 0.2 -0.3 11/04/2006 08:50:00 9.3 1.7 14.1 4.6 9 1.9 13.7 4.6 8.9 1.7 12.6 4.2 338 11 350 165 0 0 0.2 -0.1 11/04/2006 09:00:00 8 1.7 11.8 3 7.7 1.7 11.8 2.6 7.8 1.7 12.2 3.4 339 12 357 165 0.5 0.2 0.9 -0.1 11/04/2006 09:10:00 7.3 2.1 11.8 3.4 7.1 2 12.2 3 7 2.1 12.2 3 332 17 332 165 0.8 0 1.1 0.7 11/04/2006 09:20:00 8.2 1.8 12.2 4.2 8.1 1.7 12.6 4.6 8.3 1.8 12.6 4.6 334 15 336 165 0.9 0 1.1 0.9 11/04/2006 09:30:00 8.9 1.7 12.6 4.6 8.5 1.6 12.6 4.2 8.6 1.5 11.8 4.9 335 11 336 165 0.9 0 1.4 0.9 11/04/2006 09:40:00 8.1 2 12.6 4.2 8.1 2 13 3.4 7.9 2 13.3 4.2 333 13 330 165 1.2 0 1.4 1.1 11/04/2006 09:50:00 7.1 2.5 11.5 1.1 7 2.5 12.2 1.1 7 2.6 13.7 1.5 326 17 341 165 1.2 0 1.6 0.9 11/04/2006 10:00:00 4.2 1.1 7.2 1.9 4.2 1.1 7.6 2.3 4.1 1.2 7.2 1.9 322 19 337 165 1.6 0 1.8 1.4 11/04/2006 10:10:00 5.5 1.5 9.1 0.7 5.4 1.5 9.5 1.9 5.1 1.5 9.9 1.9 322 21 318 165 1.7 0.1 1.8 1.1 11/04/2006 10:20:00 6.5 1.4 9.9 2.6 6.1 1.5 9.9 3 6.2 1.3 9.9 3 338 18 332 165 1.9 0.1 2.3 1.6 11/04/2006 10:30:00 5.9 1.6 11.1 2.6 5.8 1.6 11.1 2.6 5.4 1.2 9.1 3 324 17 333 165 1.7 0 1.8 1.6 11/04/2006 10:40:00 7.9 1.7 13 3.8 7.1 1.5 11.5 3.8 7.6 1.8 13.7 4.2 335 19 355 165 2 0 2.3 1.8 11/04/2006 10:50:00 9.1 1.5 13 4.9 8.9 1.5 13 4.6 8.9 1.4 12.2 5.7 334 10 344 165 1.8 0 2.3 1.6 11/04/2006 11:00:00 5.6 0.8 8 3.4 5.7 0.8 7.6 3.4 5.4 0.9 8 2.3 321 14 318 165 2 0.2 2.3 1.6 11/04/2006 11:10:00 7 1.2 9.9 3 7 1.2 9.5 3.4 6 1.3 8.8 3 317 17 300 165 2.3 0 2.6 2.1 11/04/2006 11:20:00 6.4 1.2 9.9 3.8 6.4 1.2 9.9 3.8 5.8 1 9.1 3.4 315 17 301 165 2.4 0.1 3.3 2.1 11/04/2006 11:30:00 6.6 1.3 9.9 3.8 6.3 1.4 10.3 3.4 6.4 1.1 9.1 3.8 344 13 344 165 2.9 0.2 3.3 2.3 11/04/2006 11:40:00 7.9 1.1 11.1 5.7 7.1 1.5 10.3 3.4 7.4 1.2 10.3 4.2 348 11 355 165 3 0.1 3.5 2.8 11/04/2006 11:50:00 7.5 1.4 12.2 4.2 6.5 1.7 11.5 2.6 6.9 1.3 9.9 3.4 347 13 357 165 2.9 0.1 3.5 2.6 11/04/2006 12:00:00 7.8 1.6 13 4.6 7.5 1.9 12.6 2.6 7.8 1.5 12.2 4.2 344 9 349 165 3 0.1 3.5 2.8 11/04/2006 12:10:00 8.7 1.4 13 4.2 8.1 2 13.7 3 8.6 1.5 12.6 4.6 345 9 346 165 2.9 0 3.5 2.8 11/04/2006 12:20:00 5.5 1.2 10.3 2.6 5.3 1.4 9.9 2.3 5.3 1.3 9.9 2.6 332 19 326 165 3 0.2 3.5 2.8 11/04/2006 12:30:00 6.4 1.3 10.3 3.4 6.2 1.2 9.9 3.4 6.5 1.3 9.9 3.4 341 11 349 165 3.3 0.1 3.8 3 11/04/2006 12:40:00 8.4 1.3 11.1 5.3 7.8 1.7 11.5 4.2 8.7 1.2 11.1 5.7 344 11 345 165 3.1 0.1 3.8 2.8 11/04/2006 12:50:00 7.6 1.2 9.9 4.9 7.4 1.3 10.3 3.8 7.6 1.1 10.3 4.6 339 10 338 165 3.1 0 3.5 2.8 11/04/2006 13:00:00 6.3 1.1 9.9 3.8 6.4 1.1 9.5 3.4 5.7 1.1 8.8 3 319 19 325 165 2.9 0.1 3.3 2.6 11/04/2006 13:10:00 6.6 1.4 10.3 4.2 6.6 1.3 10.3 4.2 6.1 1.5 10.7 2.6 312 13 313 165 3.1 0.1 3.5 2.8 11/04/2006 13:20:00 6.9 1.5 11.1 4.2 6.8 1.5 11.5 3.8 6.3 1.5 10.7 3.4 314 20 321 165 3.1 0.1 3.5 2.8 11/04/2006 13:30:00 7.8 1.2 10.3 4.6 7.7 1.1 10.3 4.9 6.7 1.1 9.9 4.2 306 9 289 165 2.9 0 3.5 2.6 11/04/2006 13:40:00 7.1 1.2 10.3 4.2 7.1 1.2 10.3 4.2 6.2 1.3 9.9 2.6 313 14 325 165 3.3 0.2 3.8 2.8 11/04/2006 13:50:00 6.9 1.3 13.3 3.8 6.9 1.3 13 4.2 5.9 1.2 10.3 3.4 308 12 298 165 3.2 0.2 3.5 2.8 11/04/2006 14:00:00 7.1 1.2 9.9 3.8 7.1 1.2 10.3 3.4 5.9 1.1 9.1 2.6 304 12 301 165 3.5 0.1 3.8 3.3 11/04/2006 14:10:00 7.1 1.1 9.5 4.6 7.1 1.1 9.5 3.8 6.3 1.1 9.1 3 317 21 302 165 3.3 0 3.8 3 11/04/2006 14:20:00 7.1 1.4 11.1 3.8 6.8 1.5 11.5 3.4 6.9 1.5 10.7 3.4 344 11 351 165 3.5 0 4 3.3 11/04/2006 14:30:00 7 1.6 12.6 3.8 6.9 1.5 12.6 4.2 6.7 1.5 11.1 3.4 335 14 349 165 3.3 0 4 3 11/04/2006 14:40:00 8 1.4 12.2 4.9 7.4 1.3 12.2 4.6 7.8 1.3 11.5 4.9 343 11 359 165 3.7 0.1 4.5 3.5 11/04/2006 14:50:00 8 1.5 11.8 4.9 7.4 1.6 12.2 3.4 7.5 1.5 11.1 4.2 343 12 340 165 3.6 0 3.8 3.5 11/04/2006 15:00:00 8.8 1.4 12.2 4.6 8.5 1.5 12.6 4.6 8.4 1.4 12.6 4.6 341 10 353 165 3.5 0 4 3.3 11/04/2006 15:10:00 9.3 1.2 12.6 6.8 8.9 1.6 12.6 4.2 9.1 1.3 12.6 6.5 345 10 351 165 3.4 0 3.5 3.3 11/04/2006 15:20:00 8.9 1.5 12.6 4.9 8.4 1.6 12.6 5.3 8.5 1.5 11.8 4.2 341 10 339 165 3.3 0 3.5 3 11/04/2006 15:30:00 7.5 1.4 11.5 3.4 7.3 1.2 10.3 3.4 7.4 1.5 11.1 3.8 336 13 357 165 3.2 0 3.5 3 11/04/2006 15:40:00 5.3 1.4 8.4 1.9 5.3 1.5 8.8 1.5 4.4 1.7 8.4 1.1 327 16 343 165 3.3 0.1 3.8 3 11/04/2006 15:50:00 5.4 1.1 8.8 3 5.4 1.1 8 3 4.3 1.2 7.2 0.7 315 17 289 165 3.3 0.1 4.3 3 11/04/2006 16:00:00 5.8 1.5 9.1 1.9 5.8 1.4 9.1 2.3 4.1 1.8 8.8 0.4 310 20 321 165 3 0.2 3.5 2.6 11/04/2006 16:10:00 4.6 1.3 7.6 1.1 4.6 1.3 7.6 1.1 3.6 1.4 7.2 0.4 324 20 319 165 3 0 3.3 2.8 11/04/2006 16:20:00 5.4 1.2 9.1 2.3 5.4 1.2 8.8 2.3 4 1.4 8.4 0.4 313 19 319 165 2.7 0.1 3.3 2.6 11/04/2006 16:30:00 5.4 1.7 8.4 1.5 5.4 1.7 8.8 1.9 3.9 1.7 8 0.4 307 18 305 165 2.7 0 2.8 2.3 11/04/2006 16:40:00 6.6 1.7 9.9 1.5 6.5 1.7 9.9 1.5 5.1 1.7 8.4 0.4 301 16 274 165 2.1 0.1 2.6 1.8 11/04/2006 16:50:00 6.2 1.2 9.1 3.8 6.2 1.1 9.1 3.4 4.6 1.2 7.6 1.9 306 14 293 165 1.6 0.3 2.3 0.9 11/04/2006 17:00:00 4.8 1 7.2 2.3 4.8 1 7.6 2.3 3.7 1 6.5 0.7 316 16 317 165 0.8 0.2 1.4 0.2 11/04/2006 17:10:00 4.1 1.2 6.8 1.5 4.1 1.2 7.2 1.5 2.7 1.1 5.7 0.4 315 14 300 165 0.5 0 0.9 0.2 11/04/2006 17:20:00 5 1.5 8.4 1.9 4.9 1.4 7.6 1.9 4.2 1.7 8 0.4 329 17 350 165 0.4 0 0.7 -0.1 11/04/2006 17:30:00 5.1 1.3 8.4 1.9 4.9 1 8 3 4.4 1 6.8 1.9 339 16 2 165 0.5 0.1 0.9 -0.1 11/04/2006 17:40:00 4.7 1 7.2 2.3 4.9 1 7.6 1.9 4 1 6.5 1.1 325 11 313 165 0.3 0.1 0.7 -0.1 11/04/2006 17:50:00 5 1.2 8.4 2.3 5 1.1 8 1.9 4.4 1.1 7.6 1.9 330 15 354 165 0.2 0 0.4 -0.1 11/04/2006 18:00:00 4.5 1.2 7.6 1.5 4.5 1.2 8 1.9 3.4 1.2 7.2 0.4 323 19 344 165 0.1 0 0.7 -0.3 11/04/2006 18:10:00 3.8 1.7 8.8 0.4 3.8 1.7 8 0.7 2.7 1.7 7.6 0.4 324 22 309 165 0.2 0 0.7 -0.1 11/04/2006 18:20:00 5.1 1.3 8.8 1.5 5.1 1.4 9.1 1.1 4.1 1.6 7.2 0.4 328 17 334 165 0.1 0 0.7 -0.3 11/04/2006 18:30:00 5.1 1 7.6 3 5 1 7.2 2.6 4.5 1.1 7.6 1.5 330 13 350 165 0.1 0 0.2 -0.3 11/04/2006 18:40:00 5.4 1.2 8.4 3 5.4 1.2 8.4 3 5.1 1.4 8 1.9 332 13 348 165 0.1 0 0.4 -0.3 11/04/2006 18:50:00 7.1 1.1 10.3 4.6 7.1 1.1 10.3 3.8 6.9 1.2 10.3 4.2 338 9 344 165 0.1 0 0.4 -0.3 11/04/2006 19:00:00 8.5 0.8 10.7 6.1 8.5 0.8 10.7 6.1 8.1 0.9 10.3 5.3 339 6 337 165 0.2 0 0.7 -0.3 11/04/2006 19:10:00 8.9 1.4 12.2 5.3 8.9 1.4 12.2 5.7 8.7 1.5 11.8 4.9 337 5 338 165 0 0 0.4 -0.8 11/04/2006 19:20:00 8.9 1.3 13.7 6.1 8.9 1.3 14.1 6.1 8.8 1.4 13.7 5.7 335 7 339 165 0.1 0 0.4 -0.3 11/04/2006 19:30:00 9.6 1.4 13.7 6.1 9.5 1.4 14.1 6.1 9.3 1.3 13.7 5.7 333 9 353 165 0.3 0.1 0.7 -0.1 11/04/2006 19:40:00 9.7 1.2 13.3 7.2 9.6 1.2 13.3 6.8 9.4 1.3 13 6.5 332 8 335 165 0.3 0.1 0.7 0.2 11/04/2006 19:50:00 8.3 1.3 11.1 4.6 8.2 1.3 11.1 4.9 8.2 1.3 11.5 4.9 334 9 331 165 0.1 0 0.4 -0.1 11/04/2006 20:00:00 7.3 1.2 10.7 4.6 7.1 1.3 10.7 3.4 7.1 1.2 10.7 4.2 336 11 331 165 0.1 0.1 0.7 -0.1 11/04/2006 20:10:00 8.7 1.2 11.8 5.3 8.5 1.2 11.8 5.7 8.3 1.1 11.5 5.3 338 9 348 165 0.1 0 0.4 -0.1 11/04/2006 20:20:00 7.4 1.4 10.3 4.2 7.3 1.3 10.7 4.6 7.3 1.2 10.7 4.6 338 10 344 165 0.2 0 0.7 0.2 11/04/2006 20:30:00 6.1 1 8.8 3.4 6 1 8.4 3.8 5.8 0.8 8.4 3 332 13 339 165 0.1 0 0.7 -0.1 11/04/2006 20:40:00 7.1 1.7 11.5 4.2 6.9 1.7 11.1 3.4 6.6 1.8 11.5 3.4 337 11 349 165 -0.2 0 0.2 -0.3 11/04/2006 20:50:00 9.6 1 12.2 6.1 9.3 1.1 11.8 6.1 9.2 1.1 12.2 6.5 339 9 359 165 0.1 0 0.4 -0.1 11/04/2006 21:00:00 8.5 1.2 11.8 6.1 8.4 1.2 11.8 5.3 8.1 1.1 11.1 5.7 337 9 339 165 0.1 0 0.7 -0.1 11/04/2006 21:10:00 7.7 1.2 11.5 4.6 7.3 1.1 10.7 3.8 7.3 1.2 10.3 4.2 339 11 357 165 0.2 0 0.7 -0.1 11/04/2006 21:20:00 7.8 1.2 9.9 4.2 7.5 1.3 10.3 3.4 7.3 1.3 10.3 4.2 334 12 328 165 0.1 0 0.7 -0.1 11/04/2006 21:30:00 7.2 1.1 9.5 4.6 7 1.3 9.5 3.4 6.7 1 9.9 4.2 342 10 332 165 -0.1 0 0.4 -0.3 11/04/2006 21:40:00 6.8 1.1 9.9 4.2 6.4 1.3 10.3 3 6.4 1 9.5 4.6 346 9 336 165 -0.7 0.2 -0.1 -0.8 11/04/2006 21:50:00 6.4 1.1 8.8 3.8 6.4 1.1 9.1 3.8 6.3 1.1 9.1 3.8 333 12 312 165 -0.5 0.1 -0.3 -0.8 11/04/2006 22:00:00 6.2 1.5 10.7 3.4 6.2 1.4 11.1 3 6.3 1.6 11.5 3 335 12 344 165 0.1 0 0.2 -0.3 11/04/2006 22:10:00 5.7 1.7 10.7 1.9 5.2 1.5 9.5 1.5 6.1 1.7 11.5 2.6 343 15 358 165 0.1 0 0.7 -0.1 11/04/2006 22:20:00 4.6 1 8.4 2.3 4.4 1.2 8 1.9 4.7 1 7.2 2.6 341 14 336 165 -0.2 0 0.2 -0.5 11/04/2006 22:30:00 3.7 1.4 7.6 1.1 3.2 1.4 7.2 0.7 4 1.3 7.2 1.5 341 22 357 165 -0.2 0 -0.1 -0.5 11/04/2006 22:40:00 3.7 0.8 6.5 1.5 3.1 1 5.7 1.1 3.8 0.8 6.5 1.9 343 22 359 165 -0.3 0.1 0.2 -0.5 11/04/2006 22:50:00 3.2 0.8 5.3 1.1 3 0.8 5.3 1.5 3.4 0.7 4.9 1.9 331 17 347 165 -0.7 0.2 0.2 -1 11/04/2006 23:00:00 4 1.2 8.4 1.5 3.9 1.2 8.8 1.1 3.8 1.2 7.6 1.9 323 17 339 165 -0.9 0 -0.5 -1.2 11/04/2006 23:10:00 3.1 0.8 5.3 1.5 3.1 0.8 4.9 0.7 3.2 0.7 5.3 1.5 321 16 322 165 -0.6 0.2 -0.3 -0.8 11/04/2006 23:20:00 3.3 1.2 6.1 0.4 3.2 1.2 5.7 0.4 3.1 1.1 6.1 0.4 313 21 346 165 -0.9 0.1 -0.1 -1.2 11/04/2006 23:30:00 4.1 0.9 6.5 1.9 4.1 0.9 6.5 2.3 3.6 0.8 6.1 1.9 308 17 298 165 -0.9 0.1 -0.5 -1.2 11/04/2006 23:40:00 4.2 0.7 6.5 2.6 3.9 0.7 6.5 1.9 4.2 0.7 6.5 2.6 323 17 319 165 -0.9 0 -0.5 -1.2 11/04/2006 23:50:00 5 1 7.2 3 4.7 1.1 7.6 1.9 5 1 7.2 3.4 338 12 337 165 -1 0 -0.5 -1.2 11/05/2006 00:00:00 4.1 1.2 7.6 1.1 3.9 1.2 7.6 1.1 4 1.2 8 0.7 334 18 341 165 -0.9 0 -0.8 -1.2 11/05/2006 00:10:00 3.8 0.9 6.1 1.9 3.6 0.9 5.7 1.5 3.9 0.9 6.5 1.9 328 15 332 165 -0.8 0.1 -0.5 -0.8 11/05/2006 00:20:00 3.8 1.1 6.8 1.1 3.7 1.1 6.8 0.7 3.7 0.8 6.1 1.9 317 15 336 165 -0.9 0.1 -0.5 -1.2 11/05/2006 00:30:00 4 1 8 1.9 3.7 1.3 8 1.1 4.2 0.9 6.5 2.3 340 15 334 165 -0.9 0.1 -0.3 -1.2 11/05/2006 00:40:00 5.5 1.1 8.8 3.4 5.3 1.2 8.8 2.6 5.6 1.1 9.1 3.4 337 12 322 165 -0.9 0 -0.5 -1 11/05/2006 00:50:00 7 1 9.9 4.6 7 0.9 9.5 4.6 7.1 0.9 9.5 4.9 336 8 355 165 -0.8 0 -0.5 -1 11/05/2006 01:00:00 7.1 0.8 9.9 4.2 7.2 0.8 9.9 4.6 7.2 0.9 9.5 4.2 336 8 329 165 -0.8 0 -0.5 -1 11/05/2006 01:10:00 6 1.4 8.8 3 5.9 1.5 8.8 2.6 6.1 1.4 9.1 3 335 12 332 165 -0.8 0 -0.5 -1 11/05/2006 01:20:00 4.9 0.5 6.5 3.8 4.9 0.5 6.8 3.4 4.9 0.5 6.5 3.8 321 8 322 165 -1.1 0 -0.3 -1.4 11/05/2006 01:30:00 5.3 1 8.4 3 5.4 1 8 3 4.9 1 7.2 3 315 9 309 165 -1.3 0 -0.8 -1.4 11/05/2006 01:40:00 5.5 0.7 7.6 3.8 5.5 0.8 7.6 3.8 5.4 0.8 7.6 3.4 317 8 319 165 -1.3 0 -1 -1.4 11/05/2006 01:50:00 6.1 0.7 8.8 3.8 6.1 0.7 9.1 3.8 5.5 0.8 8 3.8 310 11 283 165 -1.3 0.1 -0.8 -1.4 11/05/2006 02:00:00 6 0.6 7.6 4.2 6.1 0.6 8 4.2 6.2 0.6 7.6 3.4 325 6 334 165 -1.4 0.1 -1.2 -1.7 11/05/2006 02:10:00 5.1 0.6 7.2 3.8 5.2 0.6 7.6 3.8 5.1 0.6 6.5 3.4 319 10 337 165 -1.3 0 -1 -1.4 11/05/2006 02:20:00 4.9 0.7 6.8 2.6 4.8 0.8 6.8 2.3 4.7 0.8 7.2 2.3 317 11 320 165 -1.3 0.1 -0.8 -1.7 11/05/2006 02:30:00 5.5 0.8 8 3.4 5.5 0.8 8 3.4 5.7 0.8 8 3.8 330 9 338 165 -1.4 0.1 -1.2 -1.9 11/05/2006 02:40:00 5 0.9 7.6 3 5 1 7.6 3 5.1 1 7.6 3.4 327 10 336 165 -1.6 0 -1.2 -1.9 11/05/2006 02:50:00 4.8 0.7 7.6 3 4.9 0.7 7.2 2.6 4.9 0.7 7.2 3.4 331 11 326 165 -1.7 0 -1.2 -1.9 11/05/2006 03:00:00 6.1 1.3 10.3 3.8 6.1 1.2 10.7 2.6 6.3 1.2 9.9 3.4 336 10 351 165 -1.6 0.2 -1.2 -1.9 11/05/2006 03:10:00 5.7 0.6 8 4.2 5.8 0.6 7.6 4.2 5.8 0.6 7.6 4.2 329 10 315 165 -1.7 0 -1.2 -1.9 11/05/2006 03:20:00 6.2 0.8 8.8 4.2 6.3 0.8 9.1 4.2 6.1 0.9 8.8 3.4 323 13 312 165 -1.6 0.1 -1.2 -1.9 11/05/2006 03:30:00 6.4 0.9 8.8 4.2 6.5 0.9 9.5 4.6 6.7 0.9 8.8 4.6 333 12 332 165 -1.6 0 -1.2 -1.9 11/05/2006 03:40:00 6 1 9.9 3.8 5.6 1.1 8.4 2.3 6.3 1 10.3 4.2 346 14 3 165 -1.5 0 -1.2 -1.7 11/05/2006 03:50:00 5.7 0.7 7.6 3.4 5.5 0.9 8 3 5.9 0.6 7.6 3.8 344 13 355 165 -1.5 0 -1.2 -1.7 11/05/2006 04:00:00 6 0.7 8.4 4.2 6 0.9 8.4 3 6.1 0.7 7.6 4.2 333 12 323 165 -1.7 0 -1.2 -1.9 11/05/2006 04:10:00 5.8 1.2 9.5 3.4 5.4 1.2 9.1 2.6 5.7 1.1 8.8 3 347 22 33 165 -1.6 0 -1.4 -1.9 11/05/2006 04:20:00 5.5 1.3 9.1 3.4 5.1 1.2 8.8 2.3 5.6 1.2 8.8 3.4 346 22 3 165 -1.4 0 -1.2 -1.7 11/05/2006 04:30:00 5 1.2 7.6 2.6 4.7 1 7.2 2.6 5.1 1.4 8.8 2.6 335 17 3 165 -1.4 0 -1.2 -1.4 11/05/2006 04:40:00 6.2 1 9.1 4.2 5.9 0.9 8.8 3 6.4 1 9.1 4.6 342 12 10 165 -1.5 0 -1.2 -1.7 11/05/2006 04:50:00 5.4 0.7 7.6 3.8 5.3 0.7 7.2 3 5.6 0.7 7.6 3.4 337 12 347 165 -1.6 0 -1.2 -1.9 11/05/2006 05:00:00 5.7 0.8 7.6 3.8 5.6 0.7 7.2 3.8 5.9 0.8 8.4 3.8 336 13 0 165 -1.6 0 -1.2 -1.9 11/05/2006 05:10:00 6.3 0.7 8.4 3.8 6.3 0.8 8 3 6.4 0.7 8.8 4.6 334 11 340 165 -1.5 0 -1.2 -1.7 11/05/2006 05:20:00 6.3 1.2 9.1 3 6.1 1.1 8.8 3 6.5 1.1 10.3 3.4 340 13 346 165 -1.5 0 -1.2 -1.7 11/05/2006 05:30:00 5.8 1 8.4 2.3 5.5 1.2 8.4 1.9 6 1 8.4 3.4 338 17 348 165 -1.4 0 -1.2 -1.7 11/05/2006 05:40:00 5.6 1.2 9.9 3.4 5.4 1.3 9.9 2.6 5.7 1.2 10.3 3.4 332 15 333 165 -1.6 0 -1.2 -1.9 11/05/2006 05:50:00 6.8 1.2 11.1 4.6 6.8 1.2 10.7 3.8 7 1.1 10.7 4.6 334 11 328 165 -1.4 0 -1 -1.4 11/05/2006 06:00:00 5.4 1 8.4 3 5.3 1 7.6 2.6 5.5 1 8.4 3 333 16 4 165 -1.4 0.1 -1 -1.7 11/05/2006 06:10:00 5.6 0.8 8 3.4 5.5 1 8 2.6 5.8 0.7 8 4.6 336 12 333 165 -1.5 0 -1.2 -1.7 11/05/2006 06:20:00 6.9 1.4 10.3 2.6 6.8 1.5 9.9 2.3 6.6 1.6 10.3 2.3 328 14 322 165 -1.5 0.1 -1 -1.9 11/05/2006 06:30:00 7.8 1.7 15.6 3.8 7.3 1.8 16.1 3.8 7.5 1.7 13.7 3 335 20 314 165 -1.3 0 -0.8 -1.4 11/05/2006 06:40:00 7.6 1.5 11.8 4.6 7.5 1.5 11.5 3.8 7.3 1.4 11.5 4.2 332 13 337 165 -1.3 0 -1 -1.4 11/05/2006 06:50:00 7.5 1 10.7 5.3 7.5 1 10.3 5.3 7.6 1 11.1 5.3 329 11 339 165 -1.2 0 -0.8 -1.4 11/05/2006 07:00:00 8.9 1.6 13.3 4.9 8.8 1.5 13 5.3 8.8 1.6 13.3 4.6 328 12 329 165 -1.2 0 -0.8 -1.4 11/05/2006 07:10:00 9 1.3 11.8 5.3 8.9 1.4 12.2 5.7 8.9 1.4 12.2 6.1 333 11 341 165 -1.3 0.1 -0.8 -1.4 11/05/2006 07:20:00 9 1.5 13.3 5.7 8.9 1.5 13 5.7 8.9 1.4 13 5.3 332 9 338 165 -1.3 0 -0.8 -1.4 11/05/2006 07:30:00 8.9 0.9 11.1 6.8 8.8 0.9 10.7 6.5 8.9 0.8 10.7 6.8 331 6 331 165 -1.3 0 -0.8 -1.4 11/05/2006 07:40:00 9.2 1.1 11.5 6.1 9.2 1.1 11.8 6.1 9.2 1.2 11.8 6.5 337 7 326 165 -1.3 0 -1.2 -1.4 11/05/2006 07:50:00 8.7 1.2 11.5 5.7 8.7 1.3 11.5 5.3 8.7 1.1 11.5 6.1 336 8 344 165 -1.2 0 -1 -1.4 11/05/2006 08:00:00 8.5 1 11.1 5.3 8.5 1.1 11.5 6.1 8.6 1 11.1 5.7 338 9 346 165 -1.2 0 -0.8 -1.4 11/05/2006 08:10:00 8.4 1.1 11.1 6.1 8.3 1.1 10.7 5.3 8.2 1.1 11.5 5.7 335 8 333 165 -1.2 0 -0.8 -1.4 11/05/2006 08:20:00 8.8 1 10.7 5.7 8.7 1 10.7 6.1 8.5 1.2 10.7 5.3 330 7 328 165 -1.2 0 -0.8 -1.4 11/05/2006 08:30:00 7.8 0.7 9.5 6.1 7.8 0.7 9.5 5.7 7.8 0.6 9.5 6.1 330 8 333 165 -1 0 -0.8 -1.2 11/05/2006 08:40:00 5.3 0.8 7.6 3 5.3 0.8 7.6 2.6 5 0.9 7.6 2.6 316 11 311 165 -1.3 0.1 -0.8 -1.4 11/05/2006 08:50:00 5.3 0.7 7.2 3.8 5.2 0.8 6.8 3.8 5.2 0.7 6.8 3.4 323 11 341 165 -1.1 0.1 -0.8 -1.4 11/05/2006 09:00:00 5.4 0.9 7.6 3.8 5.4 1 8 3.8 5.5 0.9 8 4.2 329 9 338 165 -1.2 0.2 -0.5 -1.4 11/05/2006 09:10:00 5.1 0.5 6.5 3.8 5.1 0.6 6.8 3.8 5.1 0.6 6.8 3.8 322 11 332 165 -0.8 0.1 -0.3 -1 11/05/2006 09:20:00 4.6 0.7 6.5 3.4 4.5 0.7 6.5 3 4.7 0.6 6.5 3.4 327 9 339 165 -0.3 0.2 0.2 -0.8 11/05/2006 09:30:00 4.5 0.7 6.1 2.6 4.3 0.7 6.1 2.6 4.6 0.8 6.8 3 342 9 351 165 0.1 0.1 0.7 -0.1 11/05/2006 09:40:00 5.4 0.6 7.2 3.8 5.2 1 8 2.3 5.5 0.7 7.2 3.8 344 9 344 165 0.4 0 0.7 0.2 11/05/2006 09:50:00 5.2 0.6 6.8 3.8 4.8 0.9 6.8 2.3 5.3 0.6 6.8 3.8 346 7 339 165 0.3 0.1 0.9 -0.1 11/05/2006 10:00:00 5.1 0.6 6.8 3.8 4.8 1 6.8 2.3 5.4 0.5 6.8 3.8 346 7 343 165 0.5 0.1 0.9 0.2 11/05/2006 10:10:00 4.6 0.7 6.5 3 3.8 1 5.7 1.1 4.8 0.6 6.5 3.4 351 7 2 165 1.1 0.2 1.6 0.9 11/05/2006 10:20:00 4.3 0.5 5.3 3 3.4 0.9 5.7 1.5 4.6 0.5 5.7 3.4 353 6 355 165 1.6 0.1 1.8 1.1 11/05/2006 10:30:00 4.5 0.8 6.5 2.6 4.1 1 6.5 1.9 4.6 0.8 6.8 3 349 6 347 165 2 0 2.3 1.4 11/05/2006 10:40:00 4.8 0.6 6.1 3.8 4.4 0.7 6.1 2.3 5 0.5 6.5 3.8 347 6 345 165 2.2 0 2.6 1.8 11/05/2006 10:50:00 4.4 0.7 5.7 2.6 4.2 0.9 6.1 1.5 4.7 0.6 6.5 3.4 347 6 344 165 1.4 0.3 2.3 0.7 11/05/2006 11:00:00 4.4 0.4 5.3 3.4 4.4 0.6 5.7 2.6 4.6 0.4 5.7 3.8 343 8 346 165 0.9 0.1 1.4 0.2 11/05/2006 11:10:00 4.3 0.5 5.7 3 4.2 0.8 5.7 2.3 4.5 0.5 5.7 3.4 344 8 339 165 0.7 0.2 1.1 0.2 11/05/2006 11:20:00 4.2 0.4 5.7 3.4 3.7 1 6.1 1.9 4.4 0.5 5.7 3.4 350 10 343 165 0.9 0.1 1.4 0.7 11/05/2006 11:30:00 3.6 0.6 4.9 1.1 3 0.7 4.9 1.9 3.7 0.5 5.3 2.3 357 12 19 165 1.3 0.1 1.6 0.9 11/05/2006 11:40:00 3.4 0.5 4.6 1.5 2.8 0.7 4.9 1.5 3.8 0.5 4.9 1.9 2 12 2 165 1.3 0.1 1.6 0.9 11/05/2006 11:50:00 3.5 0.5 4.9 2.3 2.9 0.8 4.6 1.1 3.8 0.4 4.9 2.6 359 13 7 165 1.4 0 1.6 0.9 11/05/2006 12:00:00 3.1 0.6 5.3 1.9 2.2 0.6 4.6 1.1 3.6 0.5 4.9 2.6 358 7 360 165 1.5 0 1.8 1.1 11/05/2006 12:10:00 3.5 0.6 4.6 1.5 2.6 0.7 4.6 0.7 3.8 0.5 4.9 2.3 358 10 358 165 1.7 0 1.8 1.4 11/05/2006 12:20:00 3.3 0.6 4.6 1.9 2.7 0.9 4.6 1.1 3.6 0.6 4.6 1.9 350 8 343 165 3 0.7 3.8 1.4 11/05/2006 12:30:00 1.8 0.6 3.4 0.4 1.5 0.6 2.6 0.4 2.5 0.5 3.8 1.5 344 18 3 165 3.1 0.3 4 2.6 11/05/2006 12:40:00 2.1 0.5 3.4 1.1 2.2 0.5 3.4 1.1 2.6 0.4 3.4 1.5 326 11 319 165 1.9 0.2 2.8 1.4 11/05/2006 12:50:00 2.8 0.5 4.2 1.5 2.8 0.5 4.6 1.5 3.2 0.5 4.2 1.9 325 9 331 165 1.7 0 1.8 1.4 11/05/2006 13:00:00 2.6 0.6 4.2 1.1 2.5 0.7 4.2 1.1 3 0.5 4.2 1.9 336 10 344 165 1.6 0 1.8 0.9 11/05/2006 13:10:00 3.2 0.6 4.9 1.9 3.1 0.6 4.9 1.5 3.4 0.5 4.9 2.3 329 15 325 165 1.4 0.1 1.6 1.1 11/05/2006 13:20:00 3.2 0.5 4.6 1.5 3.2 0.5 4.6 1.5 3.3 0.5 4.6 1.9 317 8 305 165 1.2 0 1.6 0.9 11/05/2006 13:30:00 3.8 0.5 4.9 2.3 3.7 0.6 5.3 1.9 3.9 0.5 5.3 2.3 333 14 358 165 1.3 0 1.6 1.1 11/05/2006 13:40:00 3.2 0.7 4.9 1.9 3.2 0.7 4.9 1.9 3.5 0.6 4.9 2.3 333 10 336 165 1.5 0 1.6 1.4 11/05/2006 13:50:00 3 0.6 4.6 1.5 2.9 0.7 4.6 0.7 3.3 0.6 4.6 1.9 341 14 350 165 1.7 0 1.8 1.6 11/05/2006 14:00:00 3.1 0.6 4.9 1.1 2.3 0.8 4.6 0.7 3.5 0.5 4.9 1.9 353 8 354 165 1.8 0 2.1 1.6 11/05/2006 14:10:00 2.9 0.6 4.6 1.5 2.4 0.7 4.2 0.7 3.2 0.6 4.9 1.9 12 13 350 165 1.9 0 2.3 1.8 11/05/2006 14:20:00 3.5 0.7 5.7 1.5 3 1 4.9 0.7 3.7 0.6 5.3 2.3 16 12 18 165 2 0 2.3 1.8 11/05/2006 14:30:00 3 0.8 6.1 1.5 2.4 1 5.7 0.7 3.3 0.6 5.7 2.3 10 16 27 165 2.1 0 2.3 1.8 11/05/2006 14:40:00 3.9 0.5 5.3 2.6 3.9 0.5 5.3 2.3 4.2 0.5 5.3 2.6 27 7 25 165 2.1 0 2.3 1.8 11/05/2006 14:50:00 3.8 0.6 5.7 2.3 3.6 0.6 5.3 1.9 4 0.6 5.3 2.6 21 6 25 165 2 0 2.3 1.8 11/05/2006 15:00:00 3.3 0.7 4.9 1.9 3.1 0.8 4.9 1.1 3.6 0.6 4.9 2.3 22 9 20 165 2 0 2.3 1.8 11/05/2006 15:10:00 3.2 0.6 4.6 1.5 3.1 0.8 4.6 1.1 3.4 0.6 4.9 1.9 23 8 23 165 2 0 2.3 1.8 11/05/2006 15:20:00 3.7 0.5 4.9 2.3 3.5 0.7 4.9 1.5 3.9 0.5 4.9 2.6 22 9 16 165 1.9 0 2.3 1.8 11/05/2006 15:30:00 3.9 0.7 5.7 1.9 3.6 0.8 5.3 1.1 4.1 0.8 6.1 2.3 19 7 18 165 1.9 0 2.3 1.8 11/05/2006 15:40:00 4.6 0.6 6.1 3 3.8 0.8 5.7 1.9 4.8 0.6 6.1 3 15 9 14 165 1.9 0 2.1 1.8 11/05/2006 15:50:00 3.7 0.5 4.9 2.3 3.5 0.6 4.9 1.5 4 0.5 5.3 2.6 21 7 18 165 1.8 0 2.1 1.6 11/05/2006 16:00:00 4.6 0.8 7.2 2.6 4.6 0.8 7.2 2.6 4.7 0.8 6.8 3 34 7 40 165 1.7 0 2.1 1.6 11/05/2006 16:10:00 4.4 0.8 6.8 2.6 4.5 0.8 6.5 2.6 4.5 0.8 6.8 2.3 40 10 54 165 1.7 0 1.8 1.6 11/05/2006 16:20:00 5 0.8 7.6 3 5 0.8 7.6 2.6 4.7 0.9 6.8 2.6 53 11 52 165 1.9 0 2.1 1.8 11/05/2006 16:30:00 6 1.5 9.5 2.6 6 1.5 9.5 2.6 5.6 1.3 9.1 3 49 10 47 165 1.9 0 2.1 1.8 11/05/2006 16:40:00 6 1.1 8.8 3.4 6 1.1 8.8 3.4 5.8 1 8.4 3.4 39 10 37 165 1.9 0 2.1 1.8 11/05/2006 16:50:00 7.3 1.3 10.3 4.6 7.4 1.3 10.3 4.6 7.2 1.2 10.3 4.6 45 7 34 165 1.9 0 2.3 1.8 11/05/2006 17:00:00 5.4 0.7 7.6 3.4 5.4 0.7 7.6 3.4 5.3 0.7 7.2 3.4 57 9 61 165 1.8 0 1.8 1.6 11/05/2006 17:10:00 4.8 0.7 6.8 3.4 4.8 0.8 6.8 3 4.8 0.7 6.8 3.4 56 12 48 165 1.7 0 1.8 1.6 11/05/2006 17:20:00 5 1 7.6 3 5 1 7.6 3 4.8 0.9 8 3 47 10 54 165 1.7 0 1.8 1.6 11/05/2006 17:30:00 6 1 8.4 3.4 5.9 1.1 8 3 5.9 1 8.8 3.8 26 9 19 165 1.6 0 1.8 1.4 11/05/2006 17:40:00 6.1 0.7 8 4.2 5.4 1.3 8 2.3 6.2 0.7 8 4.2 15 11 25 165 1.6 0 1.8 1.6 11/05/2006 17:50:00 5 0.8 6.8 3 3.8 0.8 6.1 1.5 5 0.8 7.6 3 9 7 10 165 1.5 0 1.8 1.4 11/05/2006 18:00:00 6.4 0.9 8.8 4.2 5.1 1.1 8.4 2.6 6.1 0.9 8.4 4.2 9 8 20 165 1.5 0 1.8 1.4 11/05/2006 18:10:00 6.7 1 9.1 4.6 4.8 1 7.6 2.3 6.8 1 9.1 4.6 7 6 5 165 1.6 0 1.8 1.4 11/05/2006 18:20:00 6.3 1.2 9.5 3 4.3 1 7.6 2.3 6.4 1.1 9.5 4.2 3 7 6 165 1.6 0 1.8 1.4 11/05/2006 18:30:00 5 1 7.2 2.6 4.1 0.8 6.1 1.9 5.1 1 7.2 2.6 16 11 3 165 1.6 0 1.8 1.6 11/05/2006 18:40:00 4.6 1.7 9.5 1.9 4.5 1.7 9.5 1.5 4.5 1.5 9.1 2.3 29 12 29 165 1.7 0 1.8 1.6 11/05/2006 18:50:00 6 1.3 9.1 3 5.7 1.4 8.8 2.6 5.7 1.3 8.8 2.6 21 11 20 165 1.8 0 1.8 1.6 11/05/2006 19:00:00 5.9 1.5 9.5 3 5.9 1.5 9.1 3 5.8 1.4 8.8 2.6 44 11 42 165 1.7 0 1.8 1.6 11/05/2006 19:10:00 6.9 1.1 9.5 4.6 7.1 1.1 9.9 4.6 6.7 1.1 9.1 3.8 46 8 46 165 1.8 0 1.8 1.6 11/05/2006 19:20:00 6.4 1.3 10.7 3.8 6.6 1.2 10.7 3.8 6.2 1.1 9.1 3.8 44 11 45 165 1.8 0 2.1 1.6 11/05/2006 19:30:00 7 1.2 10.3 3.8 7.1 1.2 10.3 4.2 6.8 1.1 9.9 3.8 43 12 48 165 1.8 0 2.1 1.6 11/05/2006 19:40:00 7.3 1.2 9.9 4.2 7.4 1.2 10.3 4.6 7 1.1 9.5 4.6 46 8 49 165 1.8 0 2.1 1.8 11/05/2006 19:50:00 7.3 1 9.5 4.6 7.4 1 9.5 4.9 7.2 1 9.9 4.6 52 10 41 165 1.7 0 2.1 1.6 11/05/2006 20:00:00 6.9 1.2 9.5 4.6 6.9 1.2 9.5 4.2 6.8 1.1 9.1 4.6 30 11 39 165 1.8 0 1.8 1.6 11/05/2006 20:10:00 5.7 1.2 9.1 3.4 5.6 1.2 9.1 3 5.5 1 8.8 3.4 30 10 29 165 1.7 0 1.8 1.6 11/05/2006 20:20:00 6.5 1.2 9.1 4.2 6.5 1.2 9.1 3.8 6.4 1 8.8 3.8 28 10 35 165 1.8 0 1.8 1.6 11/05/2006 20:30:00 6.8 1.4 9.9 3 6.9 1.4 9.9 3 6.4 1.3 9.5 3 44 9 41 165 1.7 0 1.8 1.6 11/05/2006 20:40:00 8.2 1.1 10.7 4.6 7.9 1.3 11.1 4.2 8.1 1.1 10.7 4.9 23 11 28 165 1.7 0 1.8 1.6 11/05/2006 20:50:00 6.8 1.1 10.3 4.6 6.1 1.4 9.9 3 6.6 1.2 10.7 4.6 14 8 18 165 1.6 0 1.8 1.4 11/05/2006 21:00:00 8.5 1.1 11.1 5.3 6.5 1.5 10.3 3.4 8.3 1.2 11.1 5.3 6 8 9 165 1.5 0 1.8 1.4 11/05/2006 21:10:00 7.1 1.4 10.7 4.2 5.7 1.4 9.5 3 7.1 1.3 11.1 4.2 9 9 6 165 1.5 0 1.8 1.4 11/05/2006 21:20:00 7.2 0.9 9.1 4.6 5.7 1.2 8.4 3 7.1 1 8.8 3.8 8 8 11 165 1.4 0 1.8 1.4 11/05/2006 21:30:00 5.7 1.1 8 3.4 4.5 1.2 7.6 1.5 5.7 1.1 8.4 3 1 9 16 165 1.4 0 1.8 1.4 11/05/2006 21:40:00 7.1 1.4 10.3 4.2 5.3 1.3 9.9 2.6 7 1.3 9.9 4.2 360 9 0 165 1.5 0 1.6 1.4 11/05/2006 21:50:00 8.3 1 10.7 6.1 6.4 1.5 11.1 3.8 8 0.9 10.3 5.7 355 6 350 165 1.4 0 1.8 1.4 11/05/2006 22:00:00 8.6 1.5 12.2 4.9 6.2 1.3 9.5 3.4 8.5 1.4 11.8 5.7 358 8 359 165 1.4 0 1.6 1.4 11/05/2006 22:10:00 6.9 1.2 10.3 3.8 6.2 1.3 9.5 3.4 6.7 1.3 9.5 3.8 350 10 350 165 1.4 0 1.6 1.4 11/05/2006 22:20:00 6.8 1.1 9.5 4.6 6.9 1.2 10.3 4.6 6.6 1.1 8.8 3.8 340 7 347 165 1.3 0 1.6 1.4 11/05/2006 22:30:00 7.5 0.9 10.7 5.7 6.1 1.4 9.5 3.4 7.4 1 10.3 5.3 356 10 7 165 1.4 0 1.6 1.4 11/05/2006 22:40:00 7.1 0.9 9.5 5.3 7 1.1 9.9 3 7.2 0.9 9.9 4.9 343 8 356 165 1.4 0 1.6 1.1 11/05/2006 22:50:00 7.6 1.5 10.3 4.6 7.5 1.3 11.1 4.9 7.5 1.4 10.7 4.6 340 9 351 165 1.3 0 1.6 1.1 11/05/2006 23:00:00 7.2 0.8 9.1 5.3 7 0.9 9.1 4.6 7.2 0.9 9.1 5.3 338 11 360 165 1.2 0 1.6 0.9 11/05/2006 23:10:00 7.3 1 9.9 4.9 6.9 1.2 9.9 3.4 7.2 1 9.5 4.9 339 12 329 165 1.1 0 1.6 0.9 11/05/2006 23:20:00 8.7 1 12.2 6.5 8.7 1 11.5 6.5 8.6 0.9 11.5 5.7 334 7 325 165 1.1 0 1.4 0.9 11/05/2006 23:30:00 8.3 1.3 11.8 4.9 8.1 1.3 11.5 3.8 8 1.4 11.5 4.9 330 10 332 165 1.2 0 1.6 0.9 11/05/2006 23:40:00 8.4 1.1 10.7 5.3 8.1 1.3 10.7 3.8 8.3 1 10.3 6.1 337 12 319 165 1.1 0 1.4 0.9 11/05/2006 23:50:00 7.2 1 9.9 4.6 7 1.1 9.5 3.4 7.4 0.8 9.1 4.9 343 9 323 165 1.1 0 1.4 0.9 11/06/2006 00:00:00 6.9 0.8 9.5 4.9 6.2 1.2 9.5 3 7.1 0.8 8.8 4.9 347 12 315 165 1 0 1.4 0.9 11/06/2006 00:10:00 6 0.8 8.4 4.2 6 0.8 8 3.4 6.1 0.6 8.4 4.6 335 9 12 165 0.9 0 1.4 0.9 11/06/2006 00:20:00 6.8 0.9 9.9 4.6 5.8 1.1 9.1 3.4 6.9 1 10.3 4.9 351 11 14 165 1.1 0 1.4 0.9 11/06/2006 00:30:00 7.9 1 10.7 5.7 5.6 1.3 9.9 3 8 1 11.1 6.1 2 9 11 165 1.2 0 1.4 0.9 11/06/2006 00:40:00 6.8 1.2 11.1 4.2 6 1.2 11.1 2.6 6.8 1.1 10.7 4.2 350 15 21 165 1.1 0 1.4 0.9 11/06/2006 00:50:00 7.8 1 10.3 5.3 7.6 1.1 10.7 3 7.4 1 9.9 4.9 335 9 332 165 0.8 0 1.4 0.9 11/06/2006 01:00:00 8.3 0.9 10.7 6.1 8.2 1 10.3 4.9 8.3 0.9 11.8 6.5 338 9 341 165 0.8 0 1.1 0.7 11/06/2006 01:10:00 8.7 1.5 12.6 4.6 8.5 1.7 12.2 2.6 8.5 1.5 12.2 4.9 338 10 333 165 0.6 0 0.9 0.4 11/06/2006 01:20:00 9.4 1.5 13.3 6.1 9.5 1.5 13.7 6.1 9.4 1.5 13 6.1 341 6 340 165 0.5 0 0.9 0.2 11/06/2006 01:30:00 10 1.5 13.3 6.5 9.8 1.7 13.3 5.7 9.9 1.5 13.3 6.5 340 9 332 165 0.4 0 0.9 0.2 11/06/2006 01:40:00 9.9 1.2 13 6.8 9.9 1.3 12.6 6.5 9.7 1.5 13 6.5 333 8 328 165 0.1 0 0.7 -0.1 11/06/2006 01:50:00 11 1 13.3 8 10.9 1 13.3 8 10.9 0.9 13.3 7.6 333 7 338 165 -0.1 0 0.2 -0.3 11/06/2006 02:00:00 11.9 1.1 14.5 9.1 11.9 1.2 14.9 8.4 11.8 1.2 14.5 8.8 341 6 358 165 -0.2 0 0.2 -0.3 11/06/2006 02:10:00 12.2 1.2 14.9 8.4 12.1 1.6 15.3 6.5 11.6 1.3 14.9 8.8 343 6 350 165 -0.3 0 0.2 -0.5 11/06/2006 02:20:00 12.1 0.9 14.1 9.5 12 1.2 14.5 8.4 11.8 1.1 14.1 8.4 343 7 339 165 -0.5 0 -0.1 -0.5 11/06/2006 02:30:00 12.2 1 14.5 9.5 11.9 1.1 14.5 8.8 11.8 1.1 14.5 8.4 339 8 333 165 -0.6 0 -0.1 -0.8 11/06/2006 02:40:00 11.6 0.9 14.1 9.5 11.6 1.1 14.1 7.6 11.6 0.8 13.7 9.5 344 6 354 165 -0.8 0 -0.3 -1 11/06/2006 02:50:00 10.7 1.3 14.1 7.2 10.6 1.3 14.1 6.8 10.6 1.4 14.5 7.6 332 10 329 165 -0.9 0 -0.5 -1 11/06/2006 03:00:00 10.8 1.4 14.9 8 10.8 1.5 15.3 8 10.9 1.5 15.6 6.8 332 10 348 165 -1 0 -0.5 -1.2 11/06/2006 03:10:00 9.7 1.3 13.3 6.1 9.5 1.3 13.7 6.5 9.6 1.3 13.7 6.8 334 11 340 165 -1.1 0 -0.5 -1.4 11/06/2006 03:20:00 11.2 1.3 15.6 8.4 10.7 1.7 14.9 5.7 11.1 1.3 14.9 8.4 341 11 344 165 -1.2 0 -0.8 -1.4 11/06/2006 03:30:00 9.9 1.1 13.7 6.1 9.8 1.3 13.3 4.6 9.9 1.2 13.3 6.1 336 11 318 165 -1.4 0.1 -0.8 -1.4 11/06/2006 03:40:00 10.7 1.3 15.3 7.6 10 1.7 14.9 6.1 10.5 1.2 14.5 7.2 341 13 328 165 -1.3 0 -1.2 -1.4 11/06/2006 03:50:00 8.9 1.5 13.3 5.7 8.9 1.6 13.7 5.7 8.7 1.5 13.3 5.7 329 13 335 165 -1.4 0 -1 -1.7 11/06/2006 04:00:00 9.5 1.7 14.1 6.1 9.4 1.9 14.5 4.9 9.5 1.9 14.9 4.6 338 12 342 165 -1.4 0 -1.2 -1.7 11/06/2006 04:10:00 9.6 1.3 13 6.1 9.5 1.5 13.3 5.7 9.6 1.5 13 6.1 339 10 338 165 -1.5 0 -1.2 -1.7 11/06/2006 04:20:00 8.3 2 13 4.2 8.1 1.9 12.6 4.6 8.3 1.7 12.6 4.2 338 15 339 165 -1.4 0 -1 -1.4 11/06/2006 04:30:00 7.6 1.9 12.6 4.2 7.4 1.7 11.8 4.2 7.6 1.7 12.6 4.2 337 11 356 165 -1.6 0 -1 -1.9 11/06/2006 04:40:00 8.5 1.5 12.6 3.8 8.5 1.5 12.2 4.9 8.3 1.5 13 4.6 327 11 315 165 -1.4 0.1 -1.2 -1.7 11/06/2006 04:50:00 10.2 1.7 14.5 6.5 10.1 1.7 14.1 6.1 10.1 1.7 14.5 6.1 337 10 334 165 -1.4 0 -1.2 -1.7 11/06/2006 05:00:00 8.6 1.3 12.2 5.3 8.6 1.3 12.2 5.7 8.1 1 11.1 5.3 318 17 302 165 -1.4 0 -1 -1.4 11/06/2006 05:10:00 9.3 1.4 13.3 6.5 9.2 1.3 13 6.1 8.6 1.5 12.2 4.9 316 12 320 165 -1.4 0.1 -0.8 -1.7 11/06/2006 05:20:00 8.8 1.1 12.2 5.7 8.6 1.1 12.6 4.9 8.4 1 12.2 5.7 324 12 346 165 -1.3 0 -1 -1.4 11/06/2006 05:30:00 9.3 1.1 12.2 5.3 9.2 1 11.8 5.7 7.6 1 11.5 4.9 301 8 294 165 -1.3 0 -0.8 -1.4 11/06/2006 05:40:00 10.4 0.8 12.2 8 10.3 0.8 12.2 8 8 1 11.5 6.1 301 8 299 165 -1.5 0 -1.2 -1.7 11/06/2006 05:50:00 10.2 1.2 14.1 6.1 10.1 1.2 14.1 6.1 8.2 1.1 13 4.6 301 9 286 165 -1.7 0 -1.2 -1.9 11/06/2006 06:00:00 8.8 1.5 12.6 4.2 8.7 1.5 12.2 4.9 7.5 1.3 11.1 3.8 307 12 328 165 -1.9 0.1 -1.4 -2.1 11/06/2006 06:10:00 8.9 1.3 12.6 5.3 8.8 1.3 12.6 5.7 7.8 1.4 10.7 3.4 308 14 300 165 -2 0.1 -1.4 -2.1 11/06/2006 06:20:00 10.4 1.1 13.7 6.8 10.3 1.1 13.7 6.8 8.6 1.3 14.1 4.9 304 10 298 165 -1.9 0 -1.7 -2.1 11/06/2006 06:30:00 10.3 2 15.6 5.3 10.2 1.9 14.9 4.9 8.2 1.9 14.9 3.8 305 12 289 165 -2 0.1 -1.4 -2.1 11/06/2006 06:40:00 11.6 1.6 16.4 8 11.4 1.5 16.1 8 9.1 1.3 13 5.3 299 9 301 165 -1.8 0 -1.7 -1.9 11/06/2006 06:50:00 13.4 1.8 18.3 7.6 13.1 1.7 17.6 7.6 10.5 1.5 14.1 6.5 302 8 297 165 -1.8 0 -1.4 -1.9 11/06/2006 07:00:00 14.8 1.8 21 10.7 14.5 1.7 20.6 10.3 11.9 1.7 16.4 7.6 303 9 301 165 -1.6 0.1 -1.4 -1.9 11/06/2006 07:10:00 14.7 1.7 21.4 10.3 14.5 1.7 20.6 10.7 11.8 1.5 16.4 7.6 302 8 297 165 -1.6 0 -1.2 -1.9 11/06/2006 07:20:00 13.3 1.7 18.3 8.4 13.1 1.7 18.3 8.4 10.6 1.9 19.1 5.3 302 11 297 165 -1.5 0.1 -1.2 -1.7 11/06/2006 07:30:00 13.3 1.9 17.9 8 13 1.8 17.9 7.2 11 2 16.8 5.3 304 11 312 165 -1.6 0 -1.2 -1.9 11/06/2006 07:40:00 13.7 2.1 21 8.4 13.5 2.1 20.2 8.8 10.8 2 16.4 4.9 301 11 294 165 -1.4 0 -1.2 -1.4 11/06/2006 07:50:00 15.9 2.1 21.4 11.1 15.7 2 21 11.5 12.5 2 19.5 7.2 302 10 295 165 -1.4 0 -1.2 -1.7 11/06/2006 08:00:00 17.6 1.7 22.6 13.7 17.4 1.7 22.1 13 14.4 2 20.2 9.1 303 9 286 165 -1.4 0 -1 -1.4 11/06/2006 08:10:00 17 2.1 24.4 12.2 16.8 2 24.4 11.8 14.5 2.2 20.6 9.1 307 8 315 165 -1.4 0 -1 -1.7 11/06/2006 08:20:00 16.4 2 22.6 11.5 16.1 2 22.6 11.5 13.3 2.4 20.6 6.5 303 10 316 165 -1.4 0 -1.2 -1.7 11/06/2006 08:30:00 16.4 2.4 22.9 9.9 16.1 2.3 22.6 9.9 13.3 2.5 19.9 6.8 302 10 286 165 -1.4 0 -1 -1.4 11/06/2006 08:40:00 17 2.1 22.6 10.7 16.8 2.1 22.6 11.1 14.5 2.4 22.6 8.8 307 11 319 165 -1.3 0 -0.8 -1.4 11/06/2006 08:50:00 17.2 2.1 25.2 12.6 17 2 24.8 12.6 14.9 2.2 23.7 10.3 309 8 314 165 -0.9 0 -0.8 -1.2 11/06/2006 09:00:00 16.9 1.6 20.6 12.2 16.8 1.6 21 11.5 13.6 1.9 18.7 9.1 303 8 307 165 -0.9 0 -0.8 -1.2 11/06/2006 09:10:00 16.4 1.7 21 10.7 16.2 1.7 20.2 10.7 13.1 1.6 19.9 9.1 301 8 302 165 -0.8 0 -0.5 -1 11/06/2006 09:20:00 15.2 2 19.5 9.9 14.9 2 19.5 9.5 12.1 1.9 18.7 7.2 301 9 288 165 -0.7 0 -0.5 -0.8 11/06/2006 09:30:00 14.5 1.8 19.9 9.9 14.3 1.8 19.5 9.5 11.5 1.7 17.2 6.5 300 9 278 165 -0.5 0 -0.3 -0.8 11/06/2006 09:40:00 15.2 1.7 19.9 9.9 14.9 1.7 19.1 9.5 12.1 1.7 16.4 8 300 9 296 165 -0.3 0 -0.1 -0.5 11/06/2006 09:50:00 15.8 1.5 20.2 10.7 15.7 1.5 19.9 11.1 11.7 1.6 17.9 8.4 299 7 294 165 -0.3 0 0.2 -0.5 11/06/2006 10:00:00 15.4 1.9 19.1 8 15.3 1.9 18.7 7.6 11.7 1.7 16.8 6.8 299 7 295 165 -0.2 0 -0.1 -0.3 11/06/2006 10:10:00 15.9 2 20.2 10.7 15.8 2 20.6 10.3 12 1.7 19.1 8.8 299 9 299 165 -0.1 0 0.2 -0.3 11/06/2006 10:20:00 16.3 1.7 20.2 10.7 16.1 1.7 19.9 10.7 12.3 1.5 16.8 8.8 300 8 294 165 0 0 0.2 -0.1 11/06/2006 10:30:00 15.9 1.7 20.2 11.8 15.8 1.7 19.9 11.5 12 1.7 16.8 8 298 7 297 165 0.1 0 0.7 -0.1 11/06/2006 10:40:00 15.3 1.7 18.7 10.3 15.2 1.7 18.7 9.9 11.7 1.5 16.1 6.8 298 8 297 165 0.2 0 0.7 0.2 11/06/2006 10:50:00 14.3 2 19.5 8.8 14.3 2 19.1 8.8 11.1 1.7 15.6 6.5 297 8 301 165 0.2 0 0.7 0.2 11/06/2006 11:00:00 13.8 1.8 17.9 9.1 13.7 1.8 17.9 8.8 10.9 1.6 16.4 7.2 297 8 300 165 0.4 0 0.9 0.2 11/06/2006 11:10:00 12.1 1.8 16.4 6.8 12 1.8 16.4 6.8 9.9 1.7 15.6 5.7 299 10 302 165 0.5 0 0.9 0.2 11/06/2006 11:20:00 12.1 1.9 17.6 7.2 12.1 1.9 17.6 6.8 10.2 2 17.2 6.1 295 10 286 165 0.6 0 0.9 0.2 11/06/2006 11:30:00 11.3 1.7 15.6 6.5 11.3 1.7 15.3 6.5 9.2 1.6 13.7 5.3 298 10 294 165 0.7 0.1 0.9 0.2 11/06/2006 11:40:00 11.6 1.8 15.6 6.5 11.5 1.8 15.6 7.6 9.4 1.7 13.3 5.3 296 10 299 165 0.8 0.1 1.1 0.2 11/06/2006 11:50:00 11.6 2.3 16.1 6.1 11.5 2.2 16.1 6.1 9.7 1.9 14.9 5.3 302 12 295 165 0.8 0.1 1.4 0.4 11/06/2006 12:00:00 11.4 2.2 18.7 6.1 11.3 2.2 18.3 5.7 9.3 1.9 14.5 5.3 302 10 302 165 1 0 1.4 0.9 11/06/2006 12:10:00 12.6 2 17.2 8.4 12.6 2 17.2 8.4 10.9 2.2 16.1 6.5 290 8 293 165 1 0 1.6 0.7 11/06/2006 12:20:00 13.4 1.7 18.3 8.8 13.3 1.7 18.3 8.4 10.7 1.9 16.4 6.5 292 8 290 165 1 0 1.4 0.7 11/06/2006 12:30:00 13.7 1.7 17.9 9.5 13.6 1.7 18.3 9.5 11.2 2 17.2 7.2 292 9 288 165 1.1 0.1 1.4 0.7 11/06/2006 12:40:00 13.2 2.6 19.9 8 13.1 2.6 19.9 8.4 10.8 2.4 18.7 6.8 298 10 276 165 1.3 0.1 1.6 0.9 11/06/2006 12:50:00 15.1 2.3 21.8 9.1 15 2.2 21.4 9.5 12.1 1.9 19.5 7.6 298 10 299 165 1.2 0.1 1.6 0.7 11/06/2006 13:00:00 13.8 2.2 18.3 9.1 13.6 2.2 18.3 9.1 11.4 2 16.8 6.8 298 10 287 165 1.4 0 1.6 1.4 11/06/2006 13:10:00 13.5 2.4 17.9 8.8 13.4 2.4 17.9 8.8 10.9 1.9 14.9 6.8 298 10 302 165 1.5 0 1.8 0.9 11/06/2006 13:20:00 13.8 2.1 19.5 9.1 13.8 2.1 19.1 8.8 11 2 17.2 5.7 298 9 302 165 1.5 0.1 1.8 0.9 11/06/2006 13:30:00 14.7 2 20.2 8.8 14.6 1.9 19.9 8.8 11.1 1.7 17.6 6.5 298 8 302 165 1.6 0.1 1.8 1.1 11/06/2006 13:40:00 15.5 1.5 18.7 10.3 15.3 1.5 18.3 10.3 11.6 1.8 19.5 7.2 300 7 297 165 1.7 0.1 1.8 0.9 11/06/2006 13:50:00 16.4 1.9 21 10.3 16.2 1.8 19.9 10.3 12.2 1.8 17.9 7.6 299 7 297 165 1.7 0 2.1 1.1 11/06/2006 14:00:00 16.4 1.7 20.6 10.3 16.3 1.7 20.2 10.3 12.3 1.6 16.4 8.4 299 8 293 165 1.7 0 1.8 1.4 11/06/2006 14:10:00 17 1.5 20.2 12.2 16.9 1.5 20.2 11.8 12.6 1.5 17.2 9.5 300 6 272 165 1.7 0 1.8 1.4 11/06/2006 14:20:00 15.1 1.8 19.5 11.1 15 1.8 19.1 10.7 11.8 1.7 17.9 7.6 300 8 301 165 1.7 0.1 2.1 1.4 11/06/2006 14:30:00 16.6 1.6 20.2 11.8 16.6 1.6 19.5 11.5 12.3 1.4 15.6 8.8 299 7 298 165 1.7 0 1.8 1.4 11/06/2006 14:40:00 17.2 1.7 22.9 11.5 17 1.7 22.1 11.5 13 1.4 16.8 8.8 301 7 291 165 1.6 0 1.8 1.4 11/06/2006 14:50:00 16.7 1.7 20.6 12.2 16.6 1.7 20.2 11.8 12.2 1.5 16.1 8.4 299 6 297 165 1.6 0 1.8 0.9 11/06/2006 15:00:00 17.7 1.5 21.4 13.7 17.6 1.5 21.4 13.7 13 1.7 17.6 9.5 297 8 292 165 1.5 0.1 1.8 1.4 11/06/2006 15:10:00 17.5 1.9 21.4 12.2 17.3 2 21 12.2 13.1 1.7 17.9 8.8 296 8 300 165 1.4 0.2 1.6 0.9 11/06/2006 15:20:00 17.2 2 21.8 11.5 17.1 2 21.4 11.8 13 1.8 19.9 8.8 296 8 292 165 1.4 0.1 1.6 0.9 11/06/2006 15:30:00 17.4 2.1 21.4 11.8 17.3 2.1 21.4 11.8 12.8 1.9 19.9 8.4 298 7 300 165 1.5 0 1.6 1.4 11/06/2006 15:40:00 16.3 1.7 19.5 11.1 16.2 1.7 19.5 11.1 12.1 1.5 17.2 9.1 296 7 293 165 1.4 0.1 1.6 0.9 11/06/2006 15:50:00 15.3 1.5 18.3 11.8 15.3 1.6 18.3 11.5 11.8 1.7 16.8 8.4 293 6 292 165 1.4 0.1 1.6 0.9 11/06/2006 16:00:00 13.5 1.8 17.6 9.1 13.4 1.8 16.8 8.8 11 1.7 15.3 6.8 291 9 291 165 1.3 0.1 1.8 0.9 11/06/2006 16:10:00 14.1 2.1 18.7 9.5 14 2.1 18.3 9.5 11.1 1.6 15.6 7.6 295 9 301 165 1.3 0.1 1.6 0.9 11/06/2006 16:20:00 16 1.5 19.5 12.2 16 1.5 19.1 12.2 11.9 1.4 16.4 9.1 297 7 297 165 1.3 0.1 1.6 0.9 11/06/2006 16:30:00 16.5 1.6 19.5 11.5 16.4 1.6 19.5 11.5 12.3 1.5 17.2 8.4 295 7 297 165 1.2 0 1.4 0.7 11/06/2006 16:40:00 17.8 1.7 21 13.7 17.6 1.7 21 13.7 13.3 1.6 18.3 9.5 300 8 301 165 1.1 0 1.4 0.7 11/06/2006 16:50:00 16.8 1.7 21 11.5 16.6 1.7 20.6 10.7 13.1 1.5 16.8 9.1 302 8 301 165 0.9 0.1 1.6 0.9 11/06/2006 17:00:00 15.3 1.4 18.7 11.8 15.1 1.4 18.7 11.5 12.8 1.4 17.2 9.1 306 7 305 165 0.7 0 0.9 0.7 11/06/2006 17:10:00 16.2 1.6 19.5 11.1 16 1.7 19.5 11.1 12.7 1.5 16.8 8.8 300 9 300 165 0.7 0 0.9 0.7 11/06/2006 17:20:00 16.6 1.4 19.9 11.8 16.5 1.4 19.9 11.8 12.5 1.4 16.4 9.1 300 8 301 165 0.7 0 0.9 0.4 11/06/2006 17:30:00 16.6 1.7 21 12.2 16.5 1.7 20.6 11.8 13.3 1.3 16.8 9.5 304 7 294 165 0.6 0 0.9 0.4 11/06/2006 17:40:00 16.1 1.5 19.9 10.7 15.8 1.4 19.5 10.7 13.9 1.7 19.1 9.1 307 7 310 165 0.5 0 0.9 0.2 11/06/2006 17:50:00 16.1 1.3 19.1 12.6 15.9 1.3 19.1 12.6 13.4 1.6 19.1 9.9 304 8 313 165 0.4 0 0.9 0.2 11/06/2006 18:00:00 16.8 1.3 19.9 13 16.6 1.3 19.5 12.6 13.4 1.6 17.6 9.1 302 8 300 165 0.4 0 0.9 0.2 11/06/2006 18:10:00 16.9 1.9 21 11.8 16.7 1.9 20.6 11.5 14 1.7 18.7 9.5 304 8 297 165 0.4 0 0.9 0.2 11/06/2006 18:20:00 16.4 1.8 20.6 11.8 16.2 1.7 20.2 11.5 13.5 1.7 18.3 9.5 304 8 305 165 0.4 0 0.9 0.2 11/06/2006 18:30:00 17.3 1.5 21 13.3 17.1 1.5 20.6 13 13.8 1.5 17.6 9.9 299 9 297 165 0.5 0 0.9 0.2 11/06/2006 18:40:00 17.8 1.8 21 12.6 17.6 1.7 20.2 12.6 13.4 1.5 17.9 9.9 299 8 298 165 0.5 0 0.9 0.4 11/06/2006 18:50:00 14.9 2.3 20.2 9.9 14.8 2.2 19.9 9.9 11.6 2.1 18.3 7.2 299 8 297 165 0.6 0 0.9 0.2 11/06/2006 19:00:00 14.3 1.4 17.6 11.5 14.2 1.4 17.6 11.1 11 1.7 16.8 8 299 8 297 165 0.3 0 0.9 0.2 11/06/2006 19:10:00 17.2 1.3 20.6 13.3 17.1 1.4 20.2 13 13.7 1.9 18.3 9.5 304 6 297 165 0.4 0 0.7 0.2 11/06/2006 19:20:00 17.9 1.7 22.1 13.3 17.8 1.7 22.1 13.7 15.3 1.8 19.5 11.1 306 7 282 165 0.5 0 0.9 0.4 11/06/2006 19:30:00 17.1 2 21 9.1 17 2 20.6 9.1 13.9 1.9 19.1 9.9 305 7 296 165 0.6 0 0.9 0.4 11/06/2006 19:40:00 17 1.8 20.2 10.7 16.7 1.7 19.9 9.9 13.8 1.8 18.3 9.5 302 10 253 165 0.5 0 0.9 0.2 11/06/2006 19:50:00 14.9 1.9 20.6 11.1 14.7 1.9 20.2 10.7 13 2 18.7 8.4 308 8 306 165 0.3 0.1 0.9 0.2 11/06/2006 20:00:00 15.1 1.7 20.6 9.9 14.9 1.7 19.9 9.5 13.4 1.9 17.6 8.8 309 7 312 165 0.2 0 0.4 0.2 11/06/2006 20:10:00 15.4 1.3 19.1 10.7 15.3 1.3 19.1 10.3 12.7 1.8 17.9 8.8 305 9 304 165 0.2 0 0.7 -0.1 11/06/2006 20:20:00 15.6 1.2 18.7 11.8 15.4 1.2 18.3 11.8 13.8 1.6 17.6 9.9 309 8 298 165 0.2 0 0.7 0.2 11/06/2006 20:30:00 15.5 1.7 20.6 10.3 15.3 1.7 21 10.7 14 1.9 19.1 9.5 311 10 307 165 0.4 0 0.7 0.2 11/06/2006 20:40:00 14.3 2.5 21.4 9.1 14.1 2.4 21.8 9.1 13.1 2.6 19.9 8 313 12 302 165 0.6 0 0.9 0.4 11/06/2006 20:50:00 14.6 2.7 25.6 7.6 14.5 2.7 24.8 7.6 13.1 2.7 22.6 7.2 310 13 298 165 0.5 0 0.9 0.2 11/06/2006 21:00:00 15.3 2.6 21.8 8.4 15.1 2.5 21 8.8 14 2.6 21 9.1 312 11 300 165 0.7 0 1.4 0.2 11/06/2006 21:10:00 16.8 2.3 22.6 10.3 16.6 2.2 22.6 10.7 15.2 2.5 22.1 8.8 315 9 334 165 0.4 0.1 0.9 -0.1 11/06/2006 21:20:00 16 2.4 23.3 10.3 16 2.4 23.7 10.3 13.4 2.6 22.9 6.5 312 11 317 165 0.1 0 0.7 -0.1 11/06/2006 21:30:00 16.7 2.6 21.8 8.4 16.6 2.6 22.1 8.8 14 3.2 21.8 6.5 314 13 328 165 0 0 0.4 -0.1 11/06/2006 21:40:00 17.2 2.3 22.9 10.3 17.1 2.4 22.9 9.9 14.9 2.6 21 5.7 311 11 301 165 0.1 0.1 0.4 -0.1 11/06/2006 21:50:00 16.3 2.2 20.6 8.8 16.3 2.3 20.6 9.1 13 2.4 19.1 6.5 307 10 307 165 0.2 0 0.7 -0.1 11/06/2006 22:00:00 16.4 2.2 21 9.1 16.3 2.2 21 9.1 13 2.8 19.5 4.6 306 9 311 165 0.2 0 0.7 0.2 11/06/2006 22:10:00 16.1 2 21.4 9.9 16.1 2.2 22.6 10.3 13.3 2.8 20.2 6.1 310 10 316 165 0.1 0 0.7 -0.1 11/06/2006 22:20:00 11.6 3.2 19.9 2.3 11.6 3.2 19.9 3 8.6 3.5 19.1 1.5 303 22 316 165 -0.1 0 0.4 -0.1 11/06/2006 22:30:00 17.6 2.5 23.7 11.5 17.3 2.4 22.6 10.7 13.9 2.6 21.8 6.5 298 9 301 165 0.1 0 0.4 -0.1 11/06/2006 22:40:00 18.8 2.6 24.4 11.5 18.6 2.5 24.4 11.1 15.8 2.7 22.1 8 303 9 304 165 0.2 0 0.7 0.2 11/06/2006 22:50:00 17.6 3.3 27.1 8.4 17.5 3.2 26.8 8.8 14.1 3.3 24 4.9 302 13 305 165 0.2 0 0.7 -0.1 11/06/2006 23:00:00 15.3 2.9 23.7 6.5 15.3 2.9 22.9 6.8 11.8 3.1 19.9 4.9 304 17 316 165 -0.1 0.1 0.7 -0.3 11/06/2006 23:10:00 18 3.5 24.8 8.4 17.9 3.6 26 6.5 14.1 3.8 22.6 4.6 307 13 317 165 -0.3 0 0.2 -0.3 11/06/2006 23:20:00 15.8 4.3 26 3.4 15.8 4.5 26.8 3 12.7 4.1 21.8 2.6 303 26 316 165 -0.3 0 0.2 -0.3 11/06/2006 23:30:00 11.9 2.9 18.7 4.2 11.9 2.9 18.3 4.6 8.9 3.1 16.8 1.1 300 22 303 165 -0.4 0 0.2 -0.8 11/06/2006 23:40:00 12.7 2.9 19.5 4.6 12.7 2.9 19.5 4.6 9.4 3.2 17.9 3.4 306 20 297 165 -0.7 0 -0.3 -0.8 11/06/2006 23:50:00 16 2.8 23.3 8.8 15.9 2.8 22.9 9.1 12.7 3.6 21.8 3.8 307 14 296 165 -0.8 0 -0.3 -0.8 11/07/2006 00:00:00 19.9 3.6 27.1 9.5 19.8 3.6 27.1 10.3 17.3 4 25.6 5.7 311 11 317 165 -0.6 0 -0.3 -0.8 11/07/2006 00:10:00 23 2.5 30.2 14.9 22.8 2.5 29.4 16.1 21 2.8 29.8 13.3 312 9 313 165 -0.2 0 -0.1 -0.5 11/07/2006 00:20:00 23.6 2.6 30.2 16.4 23.3 2.6 30.2 16.8 21.8 3.1 29.4 13.3 317 9 313 165 -0.1 0 0.2 -0.3 11/07/2006 00:30:00 20.6 2.8 27.5 12.6 20.4 2.8 28.3 11.8 17.8 3.5 29.4 6.8 311 11 318 165 -0.3 0 0.2 -0.5 11/07/2006 00:40:00 21.8 2.6 28.7 14.9 21.6 2.6 28.7 16.1 19.6 3.1 26 12.2 308 10 302 165 -0.3 0 -0.1 -0.5 11/07/2006 00:50:00 25.2 2 29.1 19.1 25.1 2.1 28.7 18.3 23.8 2.3 27.5 16.8 311 6 311 165 -0.5 0 -0.1 -0.8 11/07/2006 01:00:00 24.4 2.6 29.1 15.6 24.2 2.6 29.1 16.4 22.9 3.1 29.4 16.1 310 8 312 165 -0.8 0.2 -0.3 -1.2 11/07/2006 01:10:00 23 2.2 29.1 16.8 22.8 2.3 29.1 17.2 21.8 2.7 29.4 16.4 313 8 317 165 -1.2 0 -0.8 -1.4 11/07/2006 01:20:00 22.1 2 27.9 16.4 21.8 2 27.1 16.1 21.7 2.5 27.9 15.6 319 8 324 165 -1.4 0 -1 -1.4 11/07/2006 01:30:00 21.8 2.3 27.1 14.1 21.5 2.3 26.8 13.7 20.4 2.5 26 12.6 315 8 312 165 -0.9 0.2 -0.5 -1.4 11/07/2006 01:40:00 22.5 2.2 28.7 16.4 22.2 2.2 29.1 16.4 20.3 2.7 27.1 14.1 312 7 305 165 -0.9 0 -0.5 -1.2 11/07/2006 01:50:00 24.9 2.2 29.4 18.7 24.6 2.2 29.1 18.3 23.2 2.5 28.3 16.4 316 6 316 165 -1.1 0 -0.8 -1.2 11/07/2006 02:00:00 25.1 2.4 30.9 17.6 25 2.3 30.2 18.3 22.6 3.5 29.1 12.2 310 8 307 165 -1 0 -0.5 -1.2 11/07/2006 02:10:00 23.4 2.4 29.1 13 23.4 2.4 28.7 12.6 19.4 3.2 26.3 6.8 306 7 309 165 -1 0 -0.5 -1.2 11/07/2006 02:20:00 25.3 2 30.9 19.1 25.1 2 30.6 18.7 22.8 2.9 28.7 13 310 7 305 165 -1.3 0.1 -0.8 -1.4 11/07/2006 02:30:00 27.1 2.3 31.8 19.1 26.8 2.3 31.3 18.7 25.8 2.7 32.4 16.8 313 6 316 165 -1.3 0 -1 -1.4 11/07/2006 02:40:00 26.7 2.4 32.1 19.1 26.5 2.4 31.8 17.2 25.5 2.6 32.1 19.5 315 7 309 165 -1.3 0 -1 -1.4 11/07/2006 02:50:00 25.8 2.2 30.2 19.9 25.5 2.2 29.8 18.7 24.4 2.5 30.6 16.1 315 7 311 165 -1.4 0.1 -0.8 -1.7 11/07/2006 03:00:00 25.9 2.5 30.9 16.8 25.6 2.5 30.6 16.8 25.1 2.7 31.3 16.8 316 6 317 165 -1.7 0 -1.2 -1.9 11/07/2006 03:10:00 25.5 2.4 31.8 16.8 25.2 2.4 30.9 17.6 24.9 2.5 31.3 17.2 320 8 314 165 -1.8 0 -1.4 -1.9 11/07/2006 03:20:00 24.6 2.5 32.4 17.9 24.3 2.5 32.1 18.7 24 2.7 30.2 16.8 320 8 319 165 -1.6 0 -1.4 -1.9 11/07/2006 03:30:00 25.2 2.8 33.2 17.2 24.9 2.8 33.2 17.2 24.7 3.2 32.9 16.4 322 8 307 165 -1.9 0.1 -1.4 -2.1 11/07/2006 03:40:00 29 2.6 36.3 21.4 28.7 2.6 35.9 20.6 28.2 2.7 35.9 19.9 316 6 308 165 -2 0 -1.9 -2.4 11/07/2006 03:50:00 28.2 2.4 34.4 21.8 27.9 2.4 34 21.8 27.5 2.7 34.8 21 318 6 317 165 -2.4 0.1 -1.9 -2.6 11/07/2006 04:00:00 27.4 2.6 33.2 19.9 27.1 2.6 32.9 20.2 26.6 2.8 32.9 17.2 315 7 316 165 -2.5 0 -2.1 -2.6 11/07/2006 04:10:00 26.5 2 31.8 20.2 26.2 2 31.3 20.2 25.7 2.4 31.8 19.1 315 6 302 165 -2.5 0.1 -2.1 -2.8 11/07/2006 04:20:00 25.8 2.5 30.6 18.3 25.5 2.5 30.6 18.7 25.2 2.9 31.3 16.1 316 7 314 165 -2.9 0.1 -2.6 -3.3 11/07/2006 04:30:00 23.8 2.4 29.4 16.1 23.7 2.5 28.7 15.6 22.6 2.8 30.2 15.3 311 9 304 165 -3.2 0 -2.8 -3.5 11/07/2006 04:40:00 24.9 2.4 30.2 19.5 24.7 2.4 29.8 19.5 24.7 2.6 30.9 15.3 316 7 308 165 -3.2 0 -2.8 -3.3 11/07/2006 04:50:00 24.2 2.6 29.8 16.1 24 2.6 29.8 16.4 23.4 2.7 29.8 15.6 316 8 285 165 -3.1 0 -2.8 -3.3 11/07/2006 05:00:00 26.7 2.6 32.9 21 26.4 2.6 32.9 20.6 26.1 2.8 33.2 18.3 317 7 322 165 -2.9 0 -2.6 -3.3 11/07/2006 05:10:00 29.8 2.4 35.2 21 29.5 2.4 35.2 21 29.5 2.7 36.7 19.9 317 6 316 165 -2.8 0 -2.6 -3 11/07/2006 05:20:00 28.8 2.7 36.3 19.9 28.6 2.7 35.9 19.9 28.8 2.9 35.5 21.4 318 6 319 165 -2.6 0 -2.6 -2.8 11/07/2006 05:30:00 28.4 1.8 33.2 22.6 28.2 1.8 32.9 22.1 28.3 2.1 33.6 20.2 318 6 327 165 -2.5 0 -2.4 -2.8 11/07/2006 05:40:00 26.4 2.2 32.9 20.2 26.1 2.2 32.1 20.2 26.1 2.4 32.4 19.5 319 6 319 165 -2.4 0 -2.1 -2.6 11/07/2006 05:50:00 23.2 2.2 28.7 16.8 22.9 2.3 28.7 16.4 22.2 2.6 29.1 15.3 316 7 323 165 -2.4 0 -1.9 -2.6 11/07/2006 06:00:00 24.4 2.3 30.2 17.9 24.1 2.3 29.4 17.6 23 2.7 29.4 16.1 316 6 305 165 -2.3 0 -2.1 -2.6 11/07/2006 06:10:00 24.9 2.5 30.2 18.7 24.7 2.5 29.8 18.7 23.5 2.8 29.4 14.9 315 10 314 165 -2.2 0 -1.9 -2.6 11/07/2006 06:20:00 25.6 2.6 33.2 18.3 25.5 2.6 32.9 18.3 25.2 2.7 31.8 18.3 322 11 336 165 -2 0.1 -1.7 -2.4 11/07/2006 06:30:00 24.5 2.2 31.8 17.9 24.3 2.2 31.8 17.9 24.1 2.5 33.2 17.9 319 9 336 165 -2 0 -1.4 -2.1 11/07/2006 06:40:00 23.4 2.1 28.7 18.3 23.2 2.1 28.3 17.6 22.8 2.3 28.3 16.4 317 9 309 165 -2.2 0 -1.9 -2.4 11/07/2006 06:50:00 23.6 2.3 29.4 16.1 23.4 2.3 29.8 15.6 23.3 2.4 28.3 16.8 316 8 305 165 -2.4 0 -1.9 -2.6 11/07/2006 07:00:00 22.1 2 28.3 16.4 21.9 2.1 28.3 16.4 21.6 2.3 29.1 16.4 317 9 315 165 -2.5 0 -2.1 -2.6 11/07/2006 07:10:00 23.2 2.5 30.6 13.3 22.9 2.5 30.6 13.3 23 2.7 29.4 14.1 321 8 315 165 -2.4 0 -2.1 -2.6 11/07/2006 07:20:00 23.3 2.7 30.6 16.8 23.1 2.7 29.8 16.4 22.4 2.5 28.7 16.4 315 9 297 165 -2.4 0 -2.1 -2.6 11/07/2006 07:30:00 20.5 2.6 27.5 14.5 20.3 2.5 27.5 14.5 19.5 2.5 25.6 13.7 316 11 305 165 -2.2 0.1 -1.9 -2.6 11/07/2006 07:40:00 22.1 2.4 27.5 13.7 21.9 2.4 27.9 13 21.5 2.6 29.4 14.5 319 9 321 165 -2.3 0.1 -1.9 -2.6 11/07/2006 07:50:00 22.2 2.1 27.5 17.6 21.9 2.2 27.5 17.2 21.6 2.2 27.1 16.1 319 8 310 165 -2.3 0.2 -1.9 -2.6 11/07/2006 08:00:00 23.2 2.4 29.1 16.8 22.9 2.4 28.7 17.2 22.5 2.7 29.8 15.6 321 9 315 165 -2.5 0 -2.1 -2.6 11/07/2006 08:10:00 22.1 2.2 28.7 16.4 21.8 2.3 28.3 16.4 21.2 2.4 28.7 16.1 317 9 319 165 -2.8 0.1 -2.1 -3 11/07/2006 08:20:00 22.9 2.5 29.4 14.1 22.7 2.6 29.4 13.7 21.9 2.4 27.9 13.3 315 8 298 165 -2.9 0 -2.6 -3 11/07/2006 08:30:00 20.4 2.4 26.3 14.1 20.1 2.3 26 14.1 19.5 2.6 26.3 13.7 322 10 319 165 -3 0.1 -2.6 -3.3 11/07/2006 08:40:00 17.7 1.9 22.1 13 17.5 1.9 21.8 13 16.8 2.2 22.6 11.1 319 10 321 165 -3 0 -2.8 -3.3 11/07/2006 08:50:00 15 2.2 22.6 8.8 14.7 2.1 21.8 8.8 13.8 1.8 18.7 9.1 316 11 302 165 -2.8 0 -2.6 -3 11/07/2006 09:00:00 13.2 1.8 18.3 9.1 13 1.8 17.9 8.8 12.1 1.8 17.9 7.6 315 10 323 165 -2.6 0 -2.4 -2.8 11/07/2006 09:10:00 14.3 2 19.9 8.8 14.1 2 19.5 9.1 12.4 1.9 16.8 7.2 309 11 295 165 -2.5 0 -2.1 -2.8 11/07/2006 09:20:00 14.6 2.3 20.2 10.3 14.4 2.3 20.6 9.5 13.6 2.1 19.5 9.1 317 13 308 165 -2.6 0 -2.1 -2.8 11/07/2006 09:30:00 13.9 1.9 18.7 9.1 13.7 1.9 18.7 9.1 12.9 2.1 18.3 8.8 315 9 298 165 -2.5 0 -2.1 -2.8 11/07/2006 09:40:00 15 2.2 19.9 9.9 14.9 2.2 19.5 9.5 14 2 19.5 8.8 314 11 312 165 -2.4 0 -2.1 -2.6 11/07/2006 09:50:00 15.4 2.2 20.6 9.9 15.2 2.1 20.2 9.9 14 2.1 21 9.5 312 9 301 165 -2.4 0.1 -1.9 -2.6 11/07/2006 10:00:00 15.2 2.3 22.9 10.7 15 2.4 22.9 10.7 13.6 2.1 19.9 8.4 312 10 304 165 -2.4 0 -2.1 -2.6 11/07/2006 10:10:00 13.5 1.9 20.6 8 13.4 1.9 20.6 6.1 12.7 2 18.3 8.8 319 15 310 165 -2.2 0 -1.9 -2.4 11/07/2006 10:20:00 13.6 2.2 19.9 8 13.4 2.2 19.9 8.4 12.6 2.6 19.5 6.8 321 12 317 165 -2 0 -1.7 -2.1 11/07/2006 10:30:00 12.8 2 17.6 6.8 12.6 2 17.2 6.5 11.7 2 17.2 6.5 318 11 298 165 -1.9 0.1 -1.4 -2.1 11/07/2006 10:40:00 15.1 2.9 22.6 8.4 14.9 2.9 22.1 8 14.1 3.2 22.1 8 317 12 316 165 -2.2 0.1 -1.9 -2.6 11/07/2006 10:50:00 15.8 2.7 26 9.1 15.6 2.7 26 8.4 14.4 2.9 23.3 7.2 315 17 299 165 -2.5 0 -2.1 -2.8 11/07/2006 11:00:00 16.1 2.9 22.9 10.7 15.9 2.8 23.3 10.3 15.1 3.1 22.9 8.4 319 14 306 165 -2.7 0 -2.1 -2.8 11/07/2006 11:10:00 18.8 2.1 23.7 12.2 18.6 2.2 23.7 11.8 17.9 2.3 24.4 12.6 319 9 317 165 -2.7 0 -2.4 -2.8 11/07/2006 11:20:00 17.6 2.2 23.7 11.8 17.5 2.2 23.7 11.5 17 2.3 24.8 11.5 318 9 311 165 -2.6 0 -2.4 -2.8 11/07/2006 11:30:00 16.1 2.3 22.6 10.3 15.9 2.4 21.8 9.5 15.2 2.4 20.6 9.5 318 11 322 165 -2.4 0 -2.1 -2.6 11/07/2006 11:40:00 13.1 1.9 17.9 8.8 13 1.8 17.6 8 12 1.9 17.9 6.8 314 13 300 165 -2.1 0 -1.9 -2.4 11/07/2006 11:50:00 14.2 3.8 22.1 6.8 14.1 3.8 22.1 6.8 12 3.2 19.5 5.3 304 10 301 165 -2.1 0 -1.7 -2.1 11/07/2006 12:00:00 16.8 2.9 24.4 7.2 16.6 2.9 24 6.8 15.1 2.4 22.6 6.8 314 14 291 165 -2 0 -1.7 -2.4 11/07/2006 12:10:00 17.3 1.9 23.3 11.8 17.1 1.9 23.3 11.5 15.9 2.1 21 8.8 317 11 298 165 -1.9 0 -1.4 -2.1 11/07/2006 12:20:00 18.3 2.4 25.6 12.6 18 2.3 25.2 12.6 17.3 2.7 23.7 9.1 317 10 311 165 -2 0.1 -1.4 -2.1 11/07/2006 12:30:00 18.6 2 24.8 13.7 18.4 2 24 13 17.5 2 22.6 11.8 315 10 301 165 -2 0 -1.7 -2.1 11/07/2006 12:40:00 16.8 2.3 22.1 9.9 16.6 2.2 22.1 10.7 16 2.2 23.7 10.7 320 12 328 165 -2 0 -1.7 -2.1 11/07/2006 12:50:00 17.2 1.7 21.8 12.6 16.9 1.7 21.4 12.6 16.1 2 21.8 9.5 315 10 309 165 -2 0.1 -1.4 -2.1 11/07/2006 13:00:00 16.9 1.9 23.7 11.8 16.7 1.8 22.9 11.8 15.6 2.3 22.9 9.5 314 10 318 165 -2 0 -1.7 -2.1 11/07/2006 13:10:00 16.3 1.5 20.6 11.5 16 1.5 20.2 11.8 15.3 1.8 19.5 10.7 318 7 312 165 -2 0 -1.7 -2.1 11/07/2006 13:20:00 15.3 2.1 20.6 10.3 15.1 2.1 20.2 9.5 13.5 2.2 19.1 9.1 312 10 310 165 -2 0.1 -1.4 -2.4 11/07/2006 13:30:00 14.8 1.7 21 9.5 14.7 1.7 21 9.5 12.7 2.4 17.6 8.4 307 11 303 165 -2.2 0 -1.9 -2.4 11/07/2006 13:40:00 14 2 18.3 8 13.9 2 17.9 8 11.2 2 17.9 6.1 302 8 312 165 -2.1 0 -1.9 -2.4 11/07/2006 13:50:00 14.7 1.7 19.5 11.1 14.6 1.7 19.5 10.7 12.2 1.8 17.2 8 307 8 312 165 -2.1 0 -1.9 -2.4 11/07/2006 14:00:00 13.8 2.1 18.3 7.2 13.5 2.1 17.9 6.5 12.9 2.1 17.9 6.5 317 9 315 165 -1.9 0.1 -1.7 -2.4 11/07/2006 14:10:00 15.3 1.8 18.7 9.1 15.1 1.8 18.7 8.8 14.1 1.7 18.3 9.1 314 8 303 165 -2.1 0 -1.7 -2.4 11/07/2006 14:20:00 13.5 1.4 16.8 9.9 13.2 1.4 16.8 9.9 12.3 1.5 16.8 8 313 8 299 165 -2.1 0 -1.9 -2.4 11/07/2006 14:30:00 13.7 1.7 17.9 7.6 13.5 1.7 17.6 7.6 12.6 1.7 17.2 8 315 9 309 165 -2.2 0 -1.9 -2.6 11/07/2006 14:40:00 15 1.3 17.9 11.1 14.7 1.3 17.9 11.1 14.1 1.5 18.3 9.5 318 8 316 165 -2.5 0.2 -1.9 -2.8 11/07/2006 14:50:00 15.2 1.5 18.7 11.5 14.9 1.5 18.3 11.1 14 1.5 18.3 9.9 314 8 304 165 -3 0.1 -2.6 -3.3 11/07/2006 15:00:00 13.5 1.7 18.7 9.9 13.3 1.6 17.9 9.9 12.6 1.8 18.3 7.2 314 9 319 165 -3.2 0 -2.8 -3.3 11/07/2006 15:10:00 14.1 1.5 18.7 10.7 13.9 1.5 19.1 10.3 11.7 1.5 15.3 8 306 9 297 165 -3.1 0 -2.8 -3.3 11/07/2006 15:20:00 13.5 1.2 16.4 9.9 13.3 1.2 16.4 9.1 12.8 1.2 16.1 9.5 316 7 305 165 -2.6 0.1 -2.6 -2.8 11/07/2006 15:30:00 14.1 1.8 17.9 9.9 13.9 1.8 17.9 9.9 13.7 2.2 18.7 8.4 319 8 317 165 -3 0.1 -2.4 -3.3 11/07/2006 15:40:00 16.3 1.4 20.2 12.2 16.1 1.4 19.9 12.2 15.2 1.6 19.5 9.9 314 7 309 165 -3.1 0 -2.8 -3.3 11/07/2006 15:50:00 14.3 1.7 18.7 9.5 14.1 1.7 18.3 9.5 13.3 2 17.2 8.4 314 8 316 165 -3.2 0 -2.6 -3.5 11/07/2006 16:00:00 14.1 1.8 19.5 9.1 13.8 1.9 19.1 8.4 13.3 1.7 17.6 9.5 317 9 306 165 -3.2 0 -2.8 -3.3 11/07/2006 16:10:00 14.9 1.6 17.9 9.9 14.7 1.6 17.9 9.9 14.1 1.7 17.2 8.8 317 6 317 165 -3.2 0 -2.6 -3.5 11/07/2006 16:20:00 13.9 1.6 17.9 10.7 13.6 1.6 17.6 9.9 13 1.5 16.8 9.9 318 11 316 165 -3.4 0.1 -2.8 -3.5 11/07/2006 16:30:00 13.8 1.5 17.2 9.1 13.5 1.5 17.2 9.1 13 1.7 17.2 8.4 320 10 319 165 -3.7 0 -3.3 -3.9 11/07/2006 16:40:00 12.8 1.5 16.8 9.1 12.5 1.5 16.4 8.8 11.9 1.4 17.6 8 316 9 323 165 -3.8 0 -3.5 -3.9 11/07/2006 16:50:00 13 1.4 16.4 8.4 12.8 1.4 16.4 8.4 12.6 1.5 16.8 8.4 321 9 325 165 -3.9 0 -3.5 -4.2 11/07/2006 17:00:00 13 1.3 17.6 9.9 12.8 1.3 17.2 9.1 12.2 1.3 16.1 7.6 316 8 307 165 -4 0 -3.5 -4.2 11/07/2006 17:10:00 13 1.2 15.6 9.5 12.7 1.2 15.3 9.5 12.2 1.3 15.3 9.1 316 8 308 165 -4.2 0 -3.7 -4.4 11/07/2006 17:20:00 13.4 1.4 17.6 9.9 13.1 1.4 17.2 9.9 12.5 1.5 17.6 9.1 318 9 329 165 -4.4 0 -3.9 -4.6 11/07/2006 17:30:00 12 1.3 14.9 9.1 11.8 1.3 14.9 8.8 11.3 1.3 14.9 8 317 8 314 165 -4.5 0 -3.9 -4.6 11/07/2006 17:40:00 12.8 1.5 16.4 7.6 12.6 1.5 16.4 7.6 11.9 1.5 16.1 7.6 316 9 288 165 -4.5 0 -4.2 -4.6 11/07/2006 17:50:00 13 1.6 17.2 9.1 12.7 1.5 17.2 8.4 12.9 1.6 16.8 9.1 321 7 323 165 -4.5 0 -4.2 -4.6 11/07/2006 18:00:00 12.9 1.5 16.4 10.3 12.7 1.4 16.4 9.5 12.5 1.5 16.1 8.4 321 8 316 165 -4.4 0 -4.4 -4.6 11/07/2006 18:10:00 12.4 1.5 16.1 8.8 12.2 1.4 15.6 8 12 1.5 15.6 8 321 10 313 165 -4.4 0 -3.9 -4.6 11/07/2006 18:20:00 10.4 1.2 15.3 6.8 10.3 1.3 15.6 6.8 10.1 1.4 14.9 6.1 325 13 304 165 -4.4 0 -4.2 -4.6 11/07/2006 18:30:00 10.9 1.5 14.1 7.2 10.8 1.4 14.1 7.6 10.2 1.3 13.7 7.2 316 9 313 165 -4.3 0 -3.9 -4.4 11/07/2006 18:40:00 9.9 1.3 13.7 6.5 9.7 1.2 13 6.5 9.6 1.3 13.3 6.5 319 9 318 165 -4.3 0 -3.9 -4.6 11/07/2006 18:50:00 11.3 1.3 14.9 8.4 11.2 1.3 14.5 8.4 10.9 1.7 14.9 6.1 320 8 311 165 -4.5 0 -3.9 -4.6 11/07/2006 19:00:00 11.4 0.9 14.1 8.8 11.3 0.9 13.7 9.1 9.9 1.5 14.5 6.5 307 10 298 165 -4.8 0 -4.4 -5 11/07/2006 19:10:00 10.1 1.2 13 6.8 10 1.2 12.6 6.8 8.8 1.1 11.8 6.5 309 9 298 165 -4.7 0 -4.4 -4.8 11/07/2006 19:20:00 9.7 1.4 14.1 6.5 9.6 1.5 14.1 6.1 8.7 1.5 13.3 5.3 314 14 302 165 -4.6 0 -4.2 -4.6 11/07/2006 19:30:00 8.4 1.2 11.1 6.1 8.2 1.2 10.7 5.3 7.6 1.2 11.8 4.9 312 9 308 165 -4.7 0 -4.2 -4.6 11/07/2006 19:40:00 12.5 2.7 16.8 7.2 12.4 2.7 16.8 7.2 10.3 2.1 16.1 6.1 307 8 302 165 -4.5 0 -4.2 -4.6 11/07/2006 19:50:00 12 1.2 14.9 8.8 11.9 1.2 14.5 8.8 9.9 1.3 13 6.1 305 7 308 165 -4.5 0 -4.2 -4.6 11/07/2006 20:00:00 11.9 2 16.4 8 11.8 2 16.4 8.4 9.8 1.8 16.1 6.1 301 10 298 165 -4.5 0 -4.2 -4.6 11/07/2006 20:10:00 13.2 1.7 17.9 9.1 13.1 1.7 18.3 9.1 11.3 1.5 15.6 7.6 303 12 310 165 -4.6 0 -4.2 -4.6 11/07/2006 20:20:00 14.4 2.1 18.3 9.1 14.2 2.1 18.3 9.1 12.9 2.3 19.1 7.2 310 10 307 165 -4.7 0.1 -4.4 -4.8 11/07/2006 20:30:00 15.1 1.7 19.5 11.1 14.9 1.7 19.1 10.7 13.1 2.2 18.3 8.4 306 12 302 165 -4.7 0 -4.4 -5 11/07/2006 20:40:00 13.7 2.2 19.5 8.8 13.6 2.2 19.1 8.4 11.6 2 16.4 7.2 306 9 305 165 -4.7 0 -4.4 -4.8 11/07/2006 20:50:00 11.5 1.6 15.3 6.5 11.3 1.6 15.6 6.8 10.6 1.5 14.5 6.8 312 9 290 165 -4.8 0 -4.4 -5 11/07/2006 21:00:00 12.2 1.4 16.4 9.5 12 1.4 16.8 9.1 11.4 1.5 15.6 7.6 313 7 312 165 -5 0 -4.6 -5.3 11/07/2006 21:10:00 11.8 1.7 16.1 7.2 11.6 1.7 15.6 7.2 10.2 1.6 15.3 6.1 306 8 317 165 -5 0 -4.6 -5 11/07/2006 21:20:00 9.7 1.7 14.1 5.3 9.5 1.7 13.7 4.9 9 1.7 13 5.3 312 13 323 165 -5 0 -4.6 -5.3 11/07/2006 21:30:00 8.9 1.1 12.6 6.1 8.7 1.1 12.2 6.1 7.8 1 10.3 5.3 310 9 297 165 -5.2 0 -4.6 -5.3 11/07/2006 21:40:00 8.9 2.2 14.5 6.1 8.7 2.2 14.5 5.7 8.1 1.8 13.7 4.6 310 11 313 165 -5.3 0 -5 -5.5 11/07/2006 21:50:00 11.8 1.3 15.3 8 11.7 1.3 15.3 8 9.8 1.2 13.3 6.1 307 9 301 165 -5.3 0 -5 -5.5 11/07/2006 22:00:00 10 1.5 13.3 6.1 10 1.5 13.3 6.1 8.1 1.4 11.8 4.6 298 10 297 165 -5.4 0 -5 -5.5 11/07/2006 22:10:00 9.4 1.2 12.6 6.5 9.2 1.2 12.6 6.1 8.4 1.4 12.2 5.3 307 12 331 165 -5.4 0 -5 -5.7 11/07/2006 22:20:00 7.3 1 10.3 4.6 7.2 1 9.9 4.6 6.1 1.1 9.5 3 301 12 300 165 -5.4 0 -5 -5.7 11/07/2006 22:30:00 7.9 1.4 11.5 5.3 7.8 1.4 11.5 4.9 6.9 1.4 10.7 3 304 12 302 165 -5.4 0.1 -5.3 -5.7 11/07/2006 22:40:00 10.3 1.8 14.5 5.7 10.2 1.8 14.9 5.7 8.6 1.9 13.3 4.6 304 8 303 165 -5.3 0 -5 -5.5 11/07/2006 22:50:00 8.2 1.4 12.2 4.9 8.1 1.4 11.8 4.6 7.1 1.3 10.3 3.8 302 12 310 165 -5.5 0 -5 -5.7 11/07/2006 23:00:00 8.2 1.4 12.6 4.9 8.1 1.3 11.8 4.6 6.8 1.3 10.7 3.8 304 11 292 165 -5.6 0 -5.3 -5.7 11/07/2006 23:10:00 8.4 1.5 11.8 4.9 8.5 1.5 12.2 5.7 7.6 1.5 11.8 4.2 286 10 278 165 -5.5 0 -5.3 -5.7 11/07/2006 23:20:00 9.4 1.5 13.3 6.5 9.3 1.5 13.3 6.1 7.5 1.6 12.2 4.2 294 8 284 165 -5.5 0 -5 -5.7 11/07/2006 23:30:00 8.2 1.2 11.5 5.3 8.1 1.2 11.5 5.3 6.9 1.4 10.7 3.8 291 9 286 165 -5.7 0 -5.3 -5.7 11/07/2006 23:40:00 8.9 1.2 11.8 5.7 8.9 1.2 12.2 5.7 7.6 1.4 12.6 4.9 291 9 265 165 -5.6 0 -5.5 -5.7 11/07/2006 23:50:00 8.2 1.7 13 4.6 8.2 1.7 12.6 4.6 6.9 1.5 13 3.8 297 13 274 165 -5.6 0 -5.3 -5.7 11/08/2006 00:00:00 8 1.6 12.2 4.2 7.9 1.7 12.2 4.2 6.8 1.1 10.3 4.6 305 12 302 165 -5.6 0 -5.5 -5.7 11/08/2006 00:10:00 8 1.3 11.1 4.9 7.9 1.3 10.7 4.6 7.1 1.3 10.3 3.8 311 12 310 165 -5.6 0 -5.5 -5.7 11/08/2006 00:20:00 8.6 1.5 13.7 5.3 8.6 1.7 14.1 4.9 7.7 2 13.3 4.6 299 13 274 165 -5.5 0 -5.3 -5.7 11/08/2006 00:30:00 9.1 1.3 12.2 5.3 9.2 1.3 12.6 5.7 8.3 1.6 11.8 4.9 288 9 296 165 -5.3 0 -5 -5.5 11/08/2006 00:40:00 6.7 1.7 11.8 3.4 6.7 1.8 12.2 3.4 6 1.7 11.5 2.6 298 18 276 165 -5.3 0 -5 -5.5 11/08/2006 00:50:00 6.9 1.3 9.5 2.6 6.8 1.3 9.5 3 6.1 1.3 9.1 3 311 12 313 165 -5.3 0 -5 -5.5 11/08/2006 01:00:00 9.3 1.1 12.2 5.7 9.2 1.1 11.8 5.7 8.2 1.5 13 4.6 310 10 318 165 -5.2 0 -5 -5.3 11/08/2006 01:10:00 9.2 1.4 13 6.1 9.1 1.4 13 6.1 8.3 1.6 13.7 4.6 311 9 314 165 -5.2 0 -4.8 -5.3 11/08/2006 01:20:00 8.4 1.2 11.1 4.2 8.4 1.2 11.1 4.9 7.1 1.1 11.1 4.6 290 10 282 165 -5.3 0 -4.8 -5.5 11/08/2006 01:30:00 7.4 1.1 11.1 4.6 7.5 1.1 11.5 4.9 6.5 1.3 9.9 3.8 288 12 293 165 -5.3 0 -5 -5.5 11/08/2006 01:40:00 9.1 1.4 12.2 6.1 9 1.4 11.8 5.7 8.1 1.7 12.2 4.2 304 12 307 165 -5.4 0 -5 -5.5 11/08/2006 01:50:00 10.3 1.2 13.3 6.5 10.1 1.2 13.3 6.5 9 1.3 13.3 4.6 309 8 304 165 -5.3 0 -5 -5.5 11/08/2006 02:00:00 10.6 1.3 14.1 7.6 10.5 1.2 13.7 7.6 8.8 1.4 13 5.3 307 7 312 165 -5.3 0 -5 -5.5 11/08/2006 02:10:00 11.1 1.6 15.3 7.6 11 1.5 14.5 8 9 1.5 13 5.3 305 8 309 165 -5.4 0 -5 -5.5 11/08/2006 02:20:00 9.4 1.1 11.8 6.8 9.3 1.1 12.2 6.5 7.9 1.2 12.2 5.3 305 11 317 165 -5.5 0 -5 -5.7 11/08/2006 02:30:00 11.3 1.3 14.5 8 11.2 1.2 14.1 8 9.8 1.5 13.7 5.7 308 8 306 165 -5.6 0 -5.3 -5.7 11/08/2006 02:40:00 11.7 1.3 15.6 8 11.6 1.2 15.3 8 10.4 1.4 14.5 6.5 311 7 309 165 -5.6 0 -5.3 -5.7 11/08/2006 02:50:00 10.6 1.4 14.9 6.5 10.4 1.3 15.6 6.5 9.5 1.4 12.6 5.3 312 8 302 165 -5.8 0.1 -5.3 -5.9 11/08/2006 03:00:00 10.6 1.2 13 7.6 10.5 1.2 13.3 7.2 8.8 1.2 11.8 5.7 307 9 307 165 -5.8 0 -5.5 -5.9 11/08/2006 03:10:00 11 1.2 14.5 7.2 10.9 1.2 14.1 7.6 9.9 1.5 14.9 6.1 310 6 312 165 -6 0 -5.5 -6.4 11/08/2006 03:20:00 10.2 1.1 12.6 6.5 10.1 1.1 12.6 6.5 9.6 1.2 12.2 6.1 314 6 310 165 -6.3 0.1 -5.7 -6.6 11/08/2006 03:30:00 8.5 0.7 10.3 6.5 8.4 0.7 9.9 6.8 7.5 1 9.5 5.3 312 7 323 165 -6.5 0 -6.1 -6.6 11/08/2006 03:40:00 7.8 1.1 10.7 5.3 7.8 1 10.7 4.9 6.8 1.1 9.5 3.4 314 9 314 165 -6.5 0 -6.1 -6.8 11/08/2006 03:50:00 7.3 1.3 10.3 4.2 7.3 1.3 10.3 3.8 6.6 1.3 9.5 3.8 312 8 313 165 -6.8 0 -6.4 -6.8 11/08/2006 04:00:00 6 0.9 8.8 3.8 6 0.8 8.4 3.8 5.6 1 8.4 3.4 314 8 312 165 -6.7 0 -6.4 -6.8 11/08/2006 04:10:00 6.5 1.2 9.5 3.8 6.5 1.1 9.1 3.8 5.9 1.1 9.1 3.8 310 9 312 165 -6.5 0 -6.4 -6.8 11/08/2006 04:20:00 7.2 0.9 9.5 4.9 7.2 0.8 9.5 4.9 6.5 1 9.1 4.2 311 8 314 165 -6.5 0 -6.1 -6.8 11/08/2006 04:30:00 7 0.8 8.8 4.6 7 0.8 8.8 4.6 6.4 0.8 8 3.8 315 9 298 165 -6.8 0.1 -6.4 -7 11/08/2006 04:40:00 6.3 0.8 8.8 4.6 6.3 0.8 8.4 4.6 6 1 8.8 3.8 315 8 321 165 -6.7 0 -6.6 -6.8 11/08/2006 04:50:00 5.1 0.9 7.6 3 5.1 0.9 7.2 3 4.8 1 7.2 2.3 320 11 310 165 -6.6 0 -6.4 -6.8 11/08/2006 05:00:00 5.2 0.7 7.6 3 5.2 0.7 7.2 3 4.9 0.8 7.2 2.3 317 10 313 165 -6.7 0 -6.4 -6.8 11/08/2006 05:10:00 3.9 0.8 6.1 2.3 3.8 0.9 6.1 1.9 3.6 0.8 5.7 1.9 322 17 323 165 -6.8 0 -6.6 -7 11/08/2006 05:20:00 3.2 1 5.7 0.4 3.2 1 5.7 0.4 2.8 1 4.9 0.4 315 22 276 165 -6.8 0 -6.6 -7 11/08/2006 05:30:00 3.5 1.2 6.5 0.4 3.5 1.2 6.5 0.7 3.5 1.2 7.2 0.7 326 22 320 165 -6.8 0 -6.6 -6.8 11/08/2006 05:40:00 3.1 0.8 6.1 1.5 3.1 0.8 4.9 1.5 3.1 0.8 5.7 1.5 323 16 2 165 -6.8 0 -6.6 -6.8 11/08/2006 05:50:00 4.1 1.3 8 0.7 4.1 1.3 8 1.1 3.8 1.2 8 1.5 317 13 312 165 -6.8 0 -6.6 -6.8 11/08/2006 06:00:00 4.4 1.2 7.6 2.3 4.5 1.3 7.6 2.3 4.1 1 7.6 2.3 313 13 302 165 -6.8 0 -6.6 -6.8 11/08/2006 06:10:00 2.5 0.6 3.8 1.1 2.5 0.6 4.2 1.5 2.5 0.6 4.2 1.1 322 22 347 165 -6.9 0.1 -6.1 -7 11/08/2006 06:20:00 2.2 0.5 3.8 1.1 2.3 0.5 3.8 1.5 2.3 0.5 3.4 1.1 317 11 318 165 -6.9 0 -6.6 -7 11/08/2006 06:30:00 3.2 0.8 5.3 1.1 2.5 0.9 4.9 0.7 3.3 0.9 5.3 1.1 9 17 14 165 -7.2 0.1 -6.6 -7.4 11/08/2006 06:40:00 3 0.6 4.6 1.5 2.1 0.5 3.4 0.7 3.2 0.6 4.6 1.9 2 9 7 165 -7.5 0 -7.2 -7.6 11/08/2006 06:50:00 2.7 0.5 4.2 1.5 2.1 0.6 4.2 0.7 2.9 0.4 4.2 1.9 359 11 5 165 -7.5 0 -7.2 -7.6 11/08/2006 07:00:00 2.7 0.6 4.6 0.4 2.5 0.6 4.9 0.7 2.9 0.5 4.6 1.5 349 22 341 165 -7.5 0 -7.2 -7.6 11/08/2006 07:10:00 2.8 0.7 5.3 1.1 2.9 0.7 4.9 1.5 2.7 0.7 4.6 1.1 314 20 323 165 -7.2 0 -6.8 -7.4 11/08/2006 07:20:00 4 0.7 5.7 2.6 3.8 1 5.7 1.9 3.8 0.6 5.7 2.6 328 24 297 165 -7.3 0.1 -7 -7.6 11/08/2006 07:30:00 4.3 0.5 5.3 3 4.2 0.5 5.7 2.6 4.5 0.4 5.3 3.4 340 8 340 165 -7.9 0.2 -7.4 -8.1 11/08/2006 07:40:00 3.9 0.7 5.3 2.6 3.5 1 5.7 1.5 4 0.6 5.7 2.6 352 10 346 165 -8.1 0 -7.9 -8.3 11/08/2006 07:50:00 3.7 0.9 5.3 0.7 2.7 0.7 4.6 0.7 3.9 1 5.7 0.4 358 15 356 165 -8 0 -7.6 -8.1 11/08/2006 08:00:00 2.5 0.6 3.8 1.1 2.6 0.6 4.2 1.1 2.7 0.6 4.2 1.5 335 17 342 165 -7.7 0 -7.4 -7.9 11/08/2006 08:10:00 3.8 0.4 4.9 2.6 3.5 0.6 5.3 1.5 3.9 0.4 5.3 2.6 344 12 351 165 -7.9 0 -7.2 -8.1 11/08/2006 08:20:00 3 0.5 4.2 1.9 3 0.5 4.2 1.5 2.7 0.5 4.2 1.1 311 20 333 165 -7.7 0 -7.4 -7.9 11/08/2006 08:30:00 3.4 0.4 4.6 2.3 3.5 0.4 4.6 2.3 2.9 0.6 4.6 1.5 292 6 294 165 -7.6 0 -7.4 -7.6 11/08/2006 08:40:00 2.5 0.6 4.2 0.7 2.4 0.8 4.2 0.4 2.5 0.5 4.2 1.5 332 30 291 165 -7.5 0 -7.2 -7.6 11/08/2006 08:50:00 2.1 0.4 3 1.1 1.7 0.4 3 0.7 2.3 0.4 3.4 1.5 14 9 8 165 -7.8 0 -7.2 -7.9 11/08/2006 09:00:00 1.7 0.4 2.3 0.7 1.2 0.5 2.3 0.4 1.9 0.4 2.6 1.1 11 15 8 165 -7.8 0 -7.4 -8.1 11/08/2006 09:10:00 1.6 0.3 2.6 0.7 1.5 0.4 2.3 0.4 1.9 0.3 2.6 1.1 16 17 356 165 -7.8 0 -7.4 -8.1 11/08/2006 09:20:00 1.8 0.7 3.8 0.4 1.8 0.7 3.8 0.4 1.7 0.5 3.4 0.4 318 30 308 165 -7.7 0 -7.4 -7.9 11/08/2006 09:30:00 2.9 0.7 4.6 1.5 2.8 0.8 4.6 0.7 2.8 0.6 4.2 1.5 331 17 313 165 -7.8 0 -7.4 -8.1 11/08/2006 09:40:00 6.1 1.3 8.4 3 6 1.3 8.4 3.4 5.8 1.3 8 3 314 6 311 165 -7.6 0 -7.4 -7.9 11/08/2006 09:50:00 7.3 0.6 8.8 5.7 7.2 0.6 8.4 5.7 6.9 0.6 8.4 5.3 311 5 307 165 -7.8 0 -7.4 -8.1 11/08/2006 10:00:00 5.6 0.8 8 4.2 5.5 0.8 8 4.2 5 1 7.6 3 306 6 313 165 -7.4 0.1 -6.8 -7.6 11/08/2006 10:10:00 5.6 0.5 6.8 4.2 5.6 0.5 6.8 4.2 4.9 0.7 6.8 3.4 304 6 313 165 -6.8 0 -6.6 -7.2 11/08/2006 10:20:00 5.9 0.6 8.4 4.6 5.9 0.6 8 4.6 4.7 0.6 6.1 3.4 299 6 297 165 -6.9 0 -6.6 -7.2 11/08/2006 10:30:00 5 0.7 6.5 3.4 4.9 0.7 6.5 3 4.4 0.8 6.5 2.6 300 10 310 165 -6.8 0.1 -6.4 -7 11/08/2006 10:40:00 4.9 0.5 6.5 3.8 4.8 0.5 6.1 3.8 4.2 0.6 5.7 2.6 305 6 302 165 -6.9 0 -6.6 -7 11/08/2006 10:50:00 4.6 0.7 6.1 3 4.6 0.7 6.1 3 3.8 0.6 5.7 2.6 298 8 288 165 -6.9 0.1 -6.6 -7 11/08/2006 11:00:00 4.9 0.5 6.5 3.8 4.9 0.5 6.5 3.8 4.5 0.8 6.5 3 308 6 319 165 -6.8 0 -6.6 -7 11/08/2006 11:10:00 4.8 0.6 6.5 3.4 4.8 0.6 6.5 3.4 4.2 0.7 5.7 2.6 307 6 313 165 -6.7 0 -6.4 -6.8 11/08/2006 11:20:00 5.3 0.9 7.2 3 5.2 0.9 7.2 3.4 4.7 0.7 6.5 3 308 8 297 165 -6.6 0 -6.4 -6.8 11/08/2006 11:30:00 5.3 0.8 7.6 3.8 5.3 0.8 7.2 3.4 4.3 0.8 6.8 2.6 299 8 288 165 -6.3 0.2 -5.9 -6.8 11/08/2006 11:40:00 6.2 1 8.8 3.8 6.2 1 9.1 3.8 5 1 7.2 2.6 303 8 303 165 -6.2 0.1 -5.7 -6.6 11/08/2006 11:50:00 6.8 0.8 9.5 4.9 6.8 0.8 9.5 5.3 5.5 0.8 7.6 3.4 302 6 295 165 -6.3 0.1 -5.9 -6.6 11/08/2006 12:00:00 6.4 0.9 8.4 4.2 6.4 0.9 8.4 4.2 5.1 0.9 7.2 3 300 6 295 165 -6.2 0 -6.1 -6.6 11/08/2006 12:10:00 6.9 0.6 8.8 5.3 6.9 0.6 8.4 5.3 5.6 0.7 7.6 4.2 298 6 295 165 -6.4 0 -5.9 -6.6 11/08/2006 12:20:00 7.7 0.6 9.1 5.7 7.6 0.6 9.1 5.7 5.9 0.9 8.8 3.8 296 6 293 165 -6.4 0 -5.9 -6.6 11/08/2006 12:30:00 6.9 0.7 8.4 4.9 6.9 0.7 8.4 4.9 5.6 0.8 7.6 3.8 296 6 300 165 -6.2 0 -5.9 -6.8 11/08/2006 12:40:00 7.4 1 10.7 4.9 7.3 1 10.3 4.9 6 1 9.1 3.8 298 11 281 165 -6 0.2 -5.5 -6.6 11/08/2006 12:50:00 6.5 1.2 11.5 4.9 6.5 1.1 11.1 4.6 5.4 1.2 9.9 2.6 300 12 299 165 -5.8 0.1 -5.5 -6.1 11/08/2006 13:00:00 6.3 0.9 9.1 4.2 6.3 0.9 8.8 4.2 5.2 0.9 8 3 293 8 305 165 -5.8 0.1 -5.5 -6.1 11/08/2006 13:10:00 6.4 1.1 8.8 3.4 6.4 1.1 8.4 3.4 5.3 1 8 2.6 299 10 292 165 -5.4 0.2 -5 -6.1 11/08/2006 13:20:00 6.7 0.8 8.8 4.9 6.8 0.8 8.8 5.3 5.5 0.9 8.4 3.8 299 8 284 165 -5.5 0 -5.3 -5.7 11/08/2006 13:30:00 6.4 1 11.1 4.2 6.3 1 11.5 4.2 5.1 1.1 11.1 3 304 10 320 165 -5.2 0.2 -4.6 -5.9 11/08/2006 13:40:00 5.8 0.6 7.2 4.2 5.8 0.6 7.2 4.2 4.6 0.7 6.8 3 299 7 292 165 -5.1 0.1 -4.8 -5.5 11/08/2006 13:50:00 5.6 0.7 7.2 3.8 5.6 0.7 7.2 3.8 4.9 0.8 6.8 2.6 296 9 297 165 -5.2 0.2 -4.8 -5.7 11/08/2006 14:00:00 5.8 0.6 7.2 4.2 5.9 0.6 7.2 4.2 5.1 0.7 6.8 3.4 291 6 298 165 -5.8 0.1 -5.3 -6.1 11/08/2006 14:10:00 5.9 0.8 7.6 4.2 5.9 0.8 7.6 3.8 4.8 0.9 7.2 2.6 295 7 289 165 -5.6 0.1 -5.3 -6.1 11/08/2006 14:20:00 6.3 0.9 8.4 3.8 6.3 0.9 8.4 3.8 5.2 0.9 7.2 3 302 10 310 165 -5.4 0.2 -5 -6.1 11/08/2006 14:30:00 6.9 0.8 8.8 4.9 6.9 0.7 8.8 4.9 5.4 0.7 7.2 3.8 301 5 296 165 -6 0 -5.5 -6.6 11/08/2006 14:40:00 6.8 0.5 8 5.3 6.8 0.5 8 5.3 5.4 0.6 7.2 3.8 304 5 306 165 -6.1 0.1 -5.7 -6.4 11/08/2006 14:50:00 6.3 0.7 8 4.2 6.3 0.7 7.6 4.6 5 0.7 6.8 3.4 298 6 301 165 -6 0.1 -5.5 -6.4 11/08/2006 15:00:00 6.4 0.7 8.4 4.2 6.4 0.7 8.4 4.6 5.1 0.6 6.8 3.4 302 6 290 165 -6.1 0.2 -5.7 -6.6 11/08/2006 15:10:00 7.5 0.6 8.8 5.7 7.4 0.6 8.8 5.7 5.7 0.6 7.6 3.8 301 6 292 165 -6.2 0.2 -5.7 -6.6 11/08/2006 15:20:00 8 1 10.3 5.3 7.9 1 9.9 5.3 6.2 0.8 8.8 4.2 302 7 307 165 -6.4 0 -6.1 -6.6 11/08/2006 15:30:00 7.2 0.8 9.5 5.3 7.2 0.7 9.1 5.3 5.4 0.7 6.8 3.8 298 5 299 165 -6.1 0 -5.7 -6.4 11/08/2006 15:40:00 7.6 0.8 9.9 5.3 7.6 0.8 9.5 5.7 5.9 1 8.4 3.8 301 6 297 165 -6.4 0 -5.9 -6.6 11/08/2006 15:50:00 8.7 0.8 10.3 5.7 8.7 0.8 10.3 5.7 6.8 0.7 8.8 4.9 304 5 302 165 -6.2 0 -5.9 -6.4 11/08/2006 16:00:00 7.6 0.9 9.1 4.9 7.6 0.8 9.1 5.3 5.9 0.8 8 3.8 298 6 301 165 -6.3 0 -5.9 -6.4 11/08/2006 16:10:00 8.1 1.1 10.3 4.9 8.1 1 10.3 4.9 6.5 1 9.1 3.8 297 8 304 165 -6.1 0 -5.7 -6.4 11/08/2006 16:20:00 7.4 1 9.5 4.9 7.3 1 9.1 4.6 6.3 0.8 8.8 4.6 308 12 300 165 -5.9 0 -5.7 -6.1 11/08/2006 16:30:00 7.8 1.2 10.7 4.9 7.7 1.1 10.7 4.9 6.7 1 9.9 4.6 309 13 294 165 -6 0 -5.7 -6.1 11/08/2006 16:40:00 9.4 1 12.2 6.1 9.3 1 12.2 6.1 7.4 1 10.3 4.6 297 8 311 165 -6.2 0.1 -5.7 -6.6 11/08/2006 16:50:00 10.2 1.3 13.3 6.8 10 1.3 13 6.8 7.9 1.3 12.2 5.3 294 6 294 165 -6.5 0 -6.1 -6.6 11/08/2006 17:00:00 10.7 1 13.3 8 10.7 1 13.3 8 8.5 1.2 11.8 5.7 292 7 299 165 -6.5 0 -6.1 -6.6 11/08/2006 17:10:00 11.5 1.1 14.9 8.4 11.4 1.1 14.5 8.4 8.7 1.1 13.3 6.5 295 7 295 165 -6.5 0 -6.1 -6.8 11/08/2006 17:20:00 10.9 1.3 13.7 6.5 10.8 1.2 13.3 6.8 8.5 1.1 12.2 5.7 299 8 298 165 -6.5 0 -6.1 -6.8 11/08/2006 17:30:00 9.6 1.3 12.6 6.1 9.4 1.2 12.2 6.1 7.6 1.1 11.1 4.9 303 9 282 165 -6.5 0 -6.1 -6.8 11/08/2006 17:40:00 10.2 1.2 14.1 6.1 10.1 1.2 13.7 6.8 7.9 1.2 11.1 4.6 302 8 301 165 -6.5 0 -6.4 -6.8 11/08/2006 17:50:00 11.2 0.6 13 9.5 11 0.6 12.6 9.1 10.8 0.9 12.6 7.2 314 4 313 165 -6.4 0 -6.1 -6.6 11/08/2006 18:00:00 10.9 0.7 12.6 9.1 10.8 0.7 12.2 8.8 10 0.9 12.2 8 311 3 309 165 -6.6 0 -6.1 -6.8 11/08/2006 18:10:00 9.8 0.7 11.5 8 9.8 0.8 11.5 7.6 8.4 1.1 10.7 5.3 308 4 306 165 -6.6 0 -6.4 -6.8 11/08/2006 18:20:00 8.4 0.5 9.9 7.2 8.4 0.5 9.5 7.2 6.1 0.6 8.4 4.6 301 4 305 165 -6.6 0 -6.4 -6.8 11/08/2006 18:30:00 8.2 0.6 9.5 6.5 8.1 0.6 9.1 6.5 6 0.6 7.2 4.2 302 3 303 165 -6.5 0 -6.1 -6.6 11/08/2006 18:40:00 8.4 0.4 9.5 7.2 8.4 0.4 9.1 7.2 6.2 0.5 7.6 4.9 304 3 302 165 -6.5 0 -6.1 -6.6 11/08/2006 18:50:00 8.2 0.6 9.5 6.5 8.1 0.6 9.9 6.5 6.5 0.7 8.4 4.6 306 3 309 165 -6.5 0 -6.1 -6.6 11/08/2006 19:00:00 8.6 0.6 10.3 6.8 8.6 0.6 9.9 6.8 6.3 0.6 7.6 4.9 301 5 300 165 -6.4 0 -6.1 -6.6 11/08/2006 19:10:00 9.5 0.9 11.5 6.1 9.5 0.9 11.5 6.1 7 0.8 9.1 4.9 301 4 282 165 -6.1 0 -5.7 -6.4 11/08/2006 19:20:00 9.6 0.8 11.8 7.6 9.6 0.8 11.8 7.6 7.6 1.1 11.1 4.9 304 6 298 165 -6 0 -5.7 -6.1 11/08/2006 19:30:00 9.4 1 11.5 6.5 9.3 1 11.5 6.1 7.3 0.9 9.5 5.3 303 6 304 165 -5.9 0 -5.5 -6.1 11/08/2006 19:40:00 8.8 1 11.5 5.3 8.7 1 11.5 5.7 7.1 1 10.3 4.9 303 7 300 165 -5.9 0 -5.7 -6.1 11/08/2006 19:50:00 8.9 0.7 10.7 6.8 8.8 0.7 10.7 6.8 7.3 0.8 9.5 4.9 306 5 307 165 -6 0 -5.7 -6.1 11/08/2006 20:00:00 8.8 0.7 11.1 7.2 8.8 0.7 11.1 6.5 6.7 0.7 9.5 4.9 304 4 304 165 -6.1 0 -5.7 -6.1 11/08/2006 20:10:00 8 0.7 9.5 5.7 7.9 0.7 9.5 5.7 5.8 0.6 8 4.2 301 4 297 165 -6.3 0.1 -5.7 -6.6 11/08/2006 20:20:00 7.8 0.7 9.5 6.1 7.8 0.7 9.5 6.1 5.7 0.6 8.4 4.2 298 5 302 165 -6.5 0 -6.1 -6.6 11/08/2006 20:30:00 8.1 1.1 10.7 5.7 8.1 1.1 11.1 5.7 6 1 10.3 4.2 299 6 290 165 -6.4 0.1 -6.1 -6.6 11/08/2006 20:40:00 8.9 1.1 11.8 5.7 8.9 1.1 11.5 5.3 7 1.3 11.1 4.6 295 7 289 165 -6.4 0.1 -5.9 -6.6 11/08/2006 20:50:00 8.5 1 11.1 5.3 8.5 0.9 11.1 5.7 6.8 1.2 10.3 4.2 292 9 293 165 -5.9 0 -5.5 -6.1 11/08/2006 21:00:00 8.9 1.1 12.2 6.1 8.8 1.1 12.2 6.1 7.1 1.1 9.9 4.6 294 7 292 165 -6 0 -5.7 -6.1 11/08/2006 21:10:00 9.4 1.2 13.7 5.7 9.4 1.1 13.3 5.7 7.9 1.3 12.6 5.3 291 7 294 165 -5.9 0 -5.5 -6.1 11/08/2006 21:20:00 9 1.1 11.8 6.5 9 1.1 12.2 6.5 6.9 1.5 11.8 4.2 295 6 286 165 -5.8 0 -5.5 -5.9 11/08/2006 21:30:00 8.9 1 11.5 6.8 8.9 1 11.5 6.8 6.7 1.2 10.3 4.2 300 7 289 165 -5.8 0 -5.5 -5.9 11/08/2006 21:40:00 9.1 0.8 12.6 6.8 9.1 0.8 12.2 7.2 6.8 0.9 9.9 4.9 300 6 299 165 -5.7 0 -5.5 -5.7 11/08/2006 21:50:00 9.7 0.6 11.5 8.4 9.7 0.6 11.5 8.4 6.9 0.8 9.5 5.3 302 5 283 165 -5.6 0 -5.5 -5.7 11/08/2006 22:00:00 9.1 0.6 11.1 7.2 9 0.7 11.1 7.6 7.4 1 9.9 5.7 307 4 303 165 -5.6 0 -5.3 -5.7 11/08/2006 22:10:00 9.6 0.7 11.8 8 9.6 0.7 11.5 8 8.1 1 10.7 5.7 308 4 316 165 -5.6 0 -5.3 -5.7 11/08/2006 22:20:00 9.4 0.7 11.1 7.6 9.3 0.7 11.1 7.2 8.1 0.9 9.9 5.7 310 5 302 165 -5.5 0 -5 -5.7 11/08/2006 22:30:00 8.5 0.9 10.3 6.1 8.3 0.9 9.9 6.1 7.3 0.8 9.9 4.9 309 5 310 165 -5.5 0 -5.3 -5.7 11/08/2006 22:40:00 7.7 1 9.5 4.2 7.6 1 9.1 4.2 5.9 1 8.4 3.4 302 7 296 165 -5.5 0 -5.3 -5.7 11/08/2006 22:50:00 7.9 0.6 9.5 5.7 7.8 0.6 9.1 5.7 6.3 0.8 8.8 3.8 305 5 297 165 -5.5 0 -5.3 -5.7 11/08/2006 23:00:00 7.4 0.5 8.4 6.1 7.3 0.5 8.4 5.7 5.9 0.7 8 4.2 306 3 310 165 -5.5 0 -5.3 -5.7 11/08/2006 23:10:00 7.5 0.7 8.8 5.3 7.4 0.7 8.8 5.3 6 0.6 8 4.2 306 5 301 165 -5.5 0 -5.3 -5.7 11/08/2006 23:20:00 7.4 0.5 8.8 6.1 7.3 0.5 9.1 6.1 5.9 0.7 7.6 4.2 305 5 300 165 -5.4 0 -5.3 -5.7 11/08/2006 23:30:00 6.9 0.4 8 5.7 6.9 0.4 8 5.7 5.5 0.6 6.8 3.8 305 4 302 165 -5.3 0 -5 -5.5 11/08/2006 23:40:00 6.7 0.5 8 5.3 6.7 0.6 8 5.3 5.4 0.6 6.8 3.8 306 5 310 165 -5.4 0 -5 -5.5 11/08/2006 23:50:00 5.6 0.7 6.8 3.4 5.6 0.7 6.8 3.8 4.5 0.6 6.5 3 306 5 301 165 -5.3 0 -5 -5.5 11/09/2006 00:00:00 5 0.5 6.8 3.4 5 0.5 6.5 3.4 4.1 0.7 6.5 2.6 306 9 322 165 -5.3 0 -5 -5.5 11/09/2006 00:10:00 5.5 0.5 6.8 4.2 5.4 0.5 6.8 4.2 4.7 0.6 6.1 3 308 6 301 165 -5.3 0 -5 -5.5 11/09/2006 00:20:00 4.7 1.1 7.6 2.6 4.7 1.1 8 2.6 4.4 1.3 7.2 1.5 315 11 330 165 -5.3 0 -5 -5.5 11/09/2006 00:30:00 4 0.5 6.1 2.6 4 0.5 6.1 2.6 3.4 0.7 5.7 1.9 308 14 307 165 -5.2 0 -4.8 -5.3 11/09/2006 00:40:00 4.3 0.4 5.3 3 4.3 0.4 5.3 3.4 3.7 0.5 4.9 2.3 307 6 300 165 -5.3 0 -4.8 -5.3 11/09/2006 00:50:00 3.3 0.5 4.2 1.9 3.3 0.5 4.2 1.9 2.7 0.7 4.2 1.5 301 9 314 165 -5.3 0 -4.8 -5.5 11/09/2006 01:00:00 3.7 0.3 4.6 2.6 3.7 0.3 4.6 3 2.9 0.4 3.8 1.9 302 4 301 165 -5.2 0 -4.8 -5.3 11/09/2006 01:10:00 2.9 1 4.6 0.4 3 0.9 4.9 1.1 2.6 0.7 4.9 1.1 304 12 304 165 -5.3 0 -4.8 -5.5 11/09/2006 01:20:00 2.9 0.7 4.2 1.1 3 0.7 4.2 1.5 2.6 0.7 3.8 1.1 286 7 293 165 -5.3 0 -5 -5.5 11/09/2006 01:30:00 3.4 0.7 5.3 1.5 3.5 0.7 5.3 1.9 3.2 0.6 4.9 1.5 316 11 305 165 -5.2 0 -4.8 -5.3 11/09/2006 01:40:00 2.2 0.5 3.4 1.1 2.3 0.4 3.4 1.5 2.2 0.4 3 1.1 306 9 313 165 -5.2 0 -5 -5.3 11/09/2006 01:50:00 1.8 0.2 2.6 1.1 1.9 0.3 2.6 1.1 1.6 0.3 2.6 1.1 295 6 317 165 -5.3 0 -4.8 -5.5 11/09/2006 02:00:00 1.9 0.3 2.6 1.1 1.9 0.4 2.6 1.1 1.9 0.4 2.6 0.7 310 8 309 165 -5.3 0 -4.8 -5.5 11/09/2006 02:10:00 1.6 0.4 2.6 0.7 1.5 0.4 2.6 0.7 1.7 0.4 2.6 1.1 332 8 339 165 -5.3 0 -5.3 -5.5 11/09/2006 02:20:00 1.5 0.5 2.6 0.4 1.3 0.6 2.6 0.4 1.7 0.4 2.6 0.7 342 11 334 165 -5.3 0 -5 -5.5 11/09/2006 02:30:00 1.8 0.8 3 0.4 1.6 0.8 3 0.4 2 0.7 3 0.4 352 11 347 165 -5.3 0 -5 -5.5 11/09/2006 02:40:00 0.5 0.2 1.1 0.4 0.8 0.3 1.5 0.4 0.8 0.3 1.5 0.4 325 24 292 165 -5.3 0 -5 -5.5 11/09/2006 02:50:00 1.2 0.5 2.6 0.4 1.1 0.5 2.6 0.4 1.1 0.4 2.3 0.4 338 8 325 165 -5.4 0 -5 -5.5 11/09/2006 03:00:00 1.9 0.5 3 1.1 2.1 0.4 3 1.1 2.1 0.3 3 1.1 311 18 299 165 -5.4 0 -5.3 -5.5 11/09/2006 03:10:00 2.5 0.4 3.8 1.5 2.6 0.4 4.2 1.9 2.5 0.4 3.4 1.5 320 8 328 165 -5.4 0 -5 -5.7 11/09/2006 03:20:00 3.6 0.8 5.3 2.3 3.6 0.7 5.3 2.3 3.5 0.6 5.3 2.3 330 9 330 165 -5.4 0 -5 -5.5 11/09/2006 03:30:00 3.5 0.6 4.9 2.3 3.3 0.7 4.9 1.5 3.4 0.7 4.9 2.3 338 11 348 165 -5.3 0 -5 -5.5 11/09/2006 03:40:00 3.3 0.6 4.6 1.5 3.3 0.7 4.9 1.5 3.3 0.6 4.6 1.9 339 11 346 165 -5.3 0 -5 -5.5 11/09/2006 03:50:00 2.8 0.5 3.8 1.9 2 0.7 3.8 0.4 2.9 0.4 3.8 1.9 355 7 349 165 -5.3 0 -5 -5.5 11/09/2006 04:00:00 2 0.4 3 1.1 1.9 0.5 3 0.7 2.2 0.4 3.4 1.1 339 16 1 165 -5.4 0 -5 -5.5 11/09/2006 04:10:00 2.5 0.3 3 1.5 2.3 0.7 3.4 0.7 2.7 0.4 3.4 1.5 351 11 9 165 -5.4 0 -5 -5.7 11/09/2006 04:20:00 3.9 0.6 5.3 2.6 3.8 0.7 5.7 1.9 3.9 0.5 5.3 2.6 343 6 341 165 -5.5 0 -5 -5.7 11/09/2006 04:30:00 4.8 0.4 6.1 3.8 4.8 0.4 6.1 3.8 4.6 0.5 5.7 3.4 341 5 342 165 -5.5 0 -5 -5.7 11/09/2006 04:40:00 4.2 0.5 5.3 2.3 4.2 0.5 5.3 2.3 4.2 0.5 5.3 2.6 329 6 334 165 -5.5 0 -5 -5.7 11/09/2006 04:50:00 4.7 0.5 6.1 3.8 4.7 0.5 6.1 3.4 4.5 0.5 6.1 3.4 332 6 339 165 -5.5 0 -5.3 -5.7 11/09/2006 05:00:00 4.4 0.6 5.7 3.4 4.4 0.6 5.7 3.4 4.3 0.5 5.7 3.4 336 5 341 165 -5.4 0 -5.3 -5.7 11/09/2006 05:10:00 5.4 0.8 7.2 3.4 5.4 0.8 6.8 3.4 5.2 0.8 6.8 3.4 337 6 333 165 -5.4 0 -5 -5.5 11/09/2006 05:20:00 4.9 0.7 6.8 3.4 4.8 0.8 6.5 2.3 4.8 0.6 6.8 3.4 341 7 338 165 -5.3 0 -5 -5.5 11/09/2006 05:30:00 4.8 0.4 5.7 3.8 4.8 0.4 5.7 3.8 4.7 0.4 5.7 3.8 337 4 336 165 -5.4 0 -5 -5.5 11/09/2006 05:40:00 5 0.4 6.5 3.8 4.9 0.4 6.1 3.8 5 0.5 6.8 4.2 333 6 343 165 -5.4 0 -5 -5.5 11/09/2006 05:50:00 5.1 0.5 6.1 3.8 5.1 0.5 6.1 3.8 5 0.5 6.1 3.8 336 5 340 165 -5.4 0 -5 -5.5 11/09/2006 06:00:00 4.8 0.5 6.1 3.8 4.9 0.5 6.1 3.8 4.9 0.5 6.5 3.8 337 7 322 165 -5.3 0 -5 -5.5 11/09/2006 06:10:00 5 0.6 6.5 3 4.9 0.6 6.5 2.6 4.9 0.6 6.1 3.4 338 6 344 165 -5.4 0 -5 -5.5 11/09/2006 06:20:00 5.1 0.4 6.5 4.2 5.1 0.4 6.5 4.2 5.1 0.4 6.5 4.2 337 5 342 165 -5.4 0 -5 -5.5 11/09/2006 06:30:00 4.8 0.4 5.7 3.8 4.9 0.4 5.7 3.8 4.7 0.4 6.1 3.4 340 6 336 165 -5.4 0 -5 -5.5 11/09/2006 06:40:00 4.8 0.6 6.5 3.8 4.6 0.6 6.5 2.6 4.6 0.6 6.5 3.4 344 7 346 165 -5.4 0 -5 -5.5 11/09/2006 06:50:00 5.1 0.6 6.5 3.8 5.1 0.6 6.5 3 5 0.6 6.8 3.8 342 6 351 165 -5.4 0 -5 -5.5 11/09/2006 07:00:00 4.5 0.6 6.1 3.8 4.3 0.9 6.1 1.9 4.6 0.6 6.5 3.4 347 7 339 165 -5.4 0 -5 -5.5 11/09/2006 07:10:00 4 0.5 5.3 2.3 3.8 0.6 5.7 1.9 4.1 0.5 5.3 3 354 13 344 165 -5.3 0 -5 -5.5 11/09/2006 07:20:00 4 0.5 4.9 2.6 3.9 0.5 4.9 2.3 4 0.4 4.9 2.6 343 12 330 165 -5.3 0 -5 -5.5 11/09/2006 07:30:00 4.6 0.6 6.1 3 4.6 0.7 6.1 2.3 4.7 0.6 6.1 3 337 9 325 165 -5.3 0 -5 -5.5 11/09/2006 07:40:00 4.6 0.6 6.5 3.4 4.6 0.7 6.5 2.3 4.7 0.6 6.1 3 340 8 340 165 -5.4 0 -5 -5.5 11/09/2006 07:50:00 5.9 0.8 8.8 4.2 5.8 0.8 8.8 3.8 5.7 0.8 8.4 3.8 333 8 326 165 -5.4 0 -5 -5.5 11/09/2006 08:00:00 5.4 1 8 3.4 5.4 1 8 3.4 5.5 1 8.4 3.4 334 9 347 165 -5.4 0 -5 -5.5 11/09/2006 08:10:00 4.4 0.5 5.7 2.6 4.4 0.5 5.7 2.3 4.4 0.5 5.7 3 326 12 315 165 -5.4 0 -5 -5.7 11/09/2006 08:20:00 4.9 0.6 6.5 3.8 4.9 0.6 6.5 3.8 4.9 0.6 6.5 3.8 326 7 323 165 -5.5 0 -5 -5.7 11/09/2006 08:30:00 3.6 1 5.7 1.9 3.6 1 6.1 1.5 3.7 0.9 6.1 2.3 341 8 344 165 -5.5 0 -5 -5.7 11/09/2006 08:40:00 3.6 0.4 4.6 2.6 3.6 0.5 4.6 1.5 3.6 0.4 4.6 2.3 335 7 339 165 -5.5 0 -5 -5.7 11/09/2006 08:50:00 3.6 0.7 4.9 1.9 3.5 0.8 5.3 1.1 3.8 0.6 5.3 2.3 346 7 347 165 -5.4 0 -5 -5.7 11/09/2006 09:00:00 3.9 0.7 5.7 2.3 3.9 0.7 5.7 2.6 3.8 0.6 5.3 2.6 332 11 344 165 -5.4 0 -5.3 -5.7 11/09/2006 09:10:00 4.6 0.7 6.5 3 4.6 0.7 6.5 3 4.2 0.6 6.1 2.6 313 12 310 165 -5.4 0 -5 -5.5 11/09/2006 09:20:00 4.1 0.6 5.7 2.6 4.1 0.5 5.3 2.6 4 0.6 5.3 2.6 321 9 323 165 -5.4 0 -5 -5.5 11/09/2006 09:30:00 4.3 0.4 5.7 3.4 4.3 0.4 5.7 3.4 4.1 0.5 5.3 2.6 314 6 313 165 -5.4 0 -5 -5.5 11/09/2006 09:40:00 4.7 0.5 5.7 3.4 4.7 0.5 5.7 3.4 4 0.6 5.3 2.6 308 5 309 165 -5.4 0 -5 -5.5 11/09/2006 09:50:00 5.2 0.4 6.1 4.2 5.1 0.4 6.1 4.2 4.8 0.5 5.7 3.4 314 6 307 165 -5.4 0 -5 -5.7 11/09/2006 10:00:00 4.7 0.5 6.5 3.4 4.6 0.5 6.5 3.4 4.6 0.5 6.5 3.4 323 6 319 165 -5.4 0 -5 -5.5 11/09/2006 10:10:00 3.9 0.6 5.3 2.3 3.9 0.6 5.3 2.3 3.7 0.6 5.3 2.3 319 6 329 165 -5.2 0 -5 -5.5 11/09/2006 10:20:00 3.4 0.5 4.9 2.3 3.4 0.5 4.6 2.6 3.2 0.6 4.6 1.9 311 8 318 165 -5 0 -4.6 -5.3 11/09/2006 10:30:00 4.4 0.5 5.7 3.4 4.4 0.5 5.7 3.4 4.1 0.6 5.3 2.6 314 7 315 165 -5 0 -4.6 -5 11/09/2006 10:40:00 4.8 0.8 6.5 3 4.7 0.8 6.5 3 4.6 0.9 6.5 2.6 320 7 314 165 -4.8 0 -4.6 -5 11/09/2006 10:50:00 5 0.7 6.8 3 5 0.7 6.8 3 4.3 0.6 5.7 2.6 306 8 294 165 -5 0.1 -4.6 -5.3 11/09/2006 11:00:00 5.7 0.8 7.2 3.4 5.6 0.8 7.2 3.8 5.1 0.8 7.2 3.4 308 8 312 165 -5.4 0 -5 -5.5 11/09/2006 11:10:00 5.4 0.8 6.8 3.4 5.4 0.8 6.8 3.4 4.6 0.9 6.8 2.6 306 9 301 165 -5.4 0 -5 -5.5 11/09/2006 11:20:00 7 0.6 8.4 5.3 6.9 0.6 8.4 5.3 5.7 0.7 7.6 4.2 303 6 308 165 -5.4 0 -5 -5.7 11/09/2006 11:30:00 7.4 0.7 8.8 4.9 7.4 0.7 8.8 4.6 5.8 0.8 7.6 3.8 303 5 307 165 -5.3 0.1 -5 -5.7 11/09/2006 11:40:00 7 0.7 9.1 5.3 7 0.7 8.8 5.3 6.4 0.9 8.8 4.2 310 5 316 165 -4.4 0.3 -3.9 -5 11/09/2006 11:50:00 6.8 0.6 8.4 5.7 6.8 0.6 8.4 5.3 6.4 0.8 8.4 4.2 312 6 316 165 -4 0 -3.5 -4.2 11/09/2006 12:00:00 7.5 0.7 9.5 5.3 7.3 0.6 9.1 6.1 7.1 0.7 9.1 5.3 316 5 315 165 -3.9 0.1 -3.5 -4.2 11/09/2006 12:10:00 7.8 0.7 9.9 6.1 7.6 0.7 9.9 6.5 7 0.8 9.1 4.6 309 7 306 165 -4.2 0.2 -3.5 -4.6 11/09/2006 12:20:00 7.5 0.8 9.5 5.3 7.4 0.7 9.5 5.7 6.8 1 9.5 4.2 313 9 332 165 -3.9 0.3 -3.5 -4.6 11/09/2006 12:30:00 7.7 0.8 10.3 5.7 7.6 0.8 9.9 5.3 6.5 0.9 8.8 4.6 306 8 309 165 -3.9 0.3 -3.3 -4.4 11/09/2006 12:40:00 8 1 10.3 6.1 7.9 1 9.9 5.7 7.2 0.9 9.5 4.9 311 10 283 165 -4.5 0.2 -4.2 -4.8 11/09/2006 12:50:00 6 1.2 8.8 3.4 5.9 1.1 8.4 3.4 5.7 1.1 8.4 3 322 10 306 165 -4.3 0.2 -3.7 -4.8 11/09/2006 13:00:00 6 1.2 8.8 3.4 6 1.2 8.8 3.4 5.1 0.8 7.6 3 316 18 299 165 -3.4 0.1 -3 -4.4 11/09/2006 13:10:00 8.3 0.8 10.3 6.5 8.1 0.8 10.3 6.5 7.2 0.9 9.1 4.2 308 9 309 165 -3.9 0.1 -3.3 -4.2 11/09/2006 13:20:00 7.5 1 9.5 4.9 7.4 1 9.9 4.9 7.1 1 9.9 4.6 314 7 318 165 -4.1 0.2 -3.7 -4.6 11/09/2006 13:30:00 7.3 1 9.5 4.6 7.2 1 9.5 4.9 6.2 0.9 9.1 3.8 306 10 309 165 -4.2 0.3 -3.9 -5 11/09/2006 13:40:00 8 1.1 10.7 3 8 1.1 10.7 3.4 7.1 1 9.9 4.6 306 10 300 165 -4.8 0.1 -4.6 -5.3 11/09/2006 13:50:00 7.4 1.1 10.3 4.6 7.4 1.1 10.3 4.2 6.9 1.1 9.9 4.6 317 15 329 165 -4.7 0 -4.4 -4.8 11/09/2006 14:00:00 7.7 1 10.3 4.9 7.7 1 9.9 4.9 7.1 1 9.9 4.2 314 10 293 165 -4.5 0.2 -3.9 -4.8 11/09/2006 14:10:00 8.6 0.8 10.7 6.1 8.5 0.7 10.3 6.1 7.9 0.8 10.7 5.7 312 8 323 165 -4.1 0.1 -3.7 -4.6 11/09/2006 14:20:00 8.9 1 11.8 6.1 8.8 1 11.5 6.5 8 0.9 10.3 5.7 311 7 307 165 -4.5 0 -3.9 -4.6 11/09/2006 14:30:00 7.7 1.1 11.1 5.3 7.6 1.1 11.1 4.9 7 1 10.3 4.9 313 10 310 165 -3.8 0.2 -3.3 -4.4 11/09/2006 14:40:00 8.3 1.1 11.1 4.9 8.2 1.1 11.1 4.6 7.5 1.1 10.3 3.8 311 9 300 165 -3.7 0 -3.5 -3.9 11/09/2006 14:50:00 7.7 1 9.9 4.2 7.6 1 9.9 4.6 6.6 1 9.9 4.6 310 10 299 165 -3.8 0.1 -3.5 -3.9 11/09/2006 15:00:00 7.5 1 9.5 4.6 7.4 0.9 9.5 4.9 6.5 1 8.8 4.2 308 9 307 165 -3.8 0 -3.5 -3.9 11/09/2006 15:10:00 7.3 1.1 11.1 5.3 7.2 1.1 11.1 4.9 6.2 1 9.9 3.8 309 11 306 165 -3.8 0.1 -3.5 -3.9 11/09/2006 15:20:00 7 1 10.3 4.9 7 1 10.7 4.6 5.9 1.1 9.9 3.4 303 12 287 165 -4.1 0.2 -3.5 -4.4 11/09/2006 15:30:00 6.7 1 10.3 4.2 6.6 1 10.3 4.2 5.7 1.1 8.8 3 306 8 322 165 -4 0.1 -3.9 -4.4 11/09/2006 15:40:00 6.3 0.9 8.8 4.6 6.3 0.9 8.4 4.2 5.2 0.7 7.6 3.4 303 8 292 165 -4 0 -3.7 -4.4 11/09/2006 15:50:00 6.6 0.9 8.8 4.2 6.6 0.8 8.4 4.6 5.5 0.9 8 3.8 303 8 306 165 -4.4 0.3 -3.5 -4.6 11/09/2006 16:00:00 7.5 1.1 10.3 4.9 7.5 1.1 10.3 4.9 5.9 1 8.8 3.8 301 7 294 165 -4.8 0 -4.4 -5 11/09/2006 16:10:00 8.1 1 9.9 5.3 8 1 9.9 5.7 6.5 0.9 9.5 4.6 303 8 299 165 -4.9 0 -4.6 -5 11/09/2006 16:20:00 8.7 1 11.5 5.7 8.7 1 11.1 5.7 7 1 10.3 4.9 300 9 305 165 -5.2 0.1 -4.6 -5.5 11/09/2006 16:30:00 8.9 1.2 11.8 6.1 8.8 1.2 11.5 6.1 7.5 1.1 10.3 4.9 308 7 308 165 -5.3 0 -5 -5.5 11/09/2006 16:40:00 8.3 1 11.8 5.3 8.2 1 11.1 5.7 6.9 1.1 10.7 4.2 308 8 312 165 -5.4 0 -5 -5.5 11/09/2006 16:50:00 9.1 1 12.2 6.5 9 1 12.2 6.5 7.6 1 11.8 5.7 308 6 302 165 -5.4 0 -5 -5.7 11/09/2006 17:00:00 8.8 1.1 13 6.5 8.7 1.1 12.6 6.1 7.6 1.1 11.1 4.6 308 9 303 165 -5.4 0.1 -5 -5.7 11/09/2006 17:10:00 9.2 1.1 11.8 5.7 9.1 1.1 11.8 6.1 7.5 1 10.3 5.3 305 7 297 165 -5.4 0 -5 -5.7 11/09/2006 17:20:00 10.3 1 13 7.6 10.2 1 12.6 7.6 8.1 1 11.1 5.3 303 7 312 165 -5.5 0 -5.3 -5.7 11/09/2006 17:30:00 9.5 1 13.3 7.2 9.4 1 13.3 6.8 8.1 1 12.2 5.7 309 8 310 165 -5.4 0 -5 -5.7 11/09/2006 17:40:00 8.7 1.2 13 4.6 8.6 1.2 13 4.9 7.6 1.1 11.8 4.2 310 7 311 165 -5.3 0 -5 -5.5 11/09/2006 17:50:00 8.5 1 11.5 6.1 8.4 1 11.1 6.5 7.5 1.2 10.7 4.6 310 8 310 165 -5.3 0.1 -4.8 -5.5 11/09/2006 18:00:00 8.7 1.2 13 5.7 8.6 1.3 12.6 5.3 7.9 1.2 11.5 5.3 313 11 293 165 -5 0 -4.8 -5.3 11/09/2006 18:10:00 6.8 1.1 10.3 3.8 6.7 1.1 9.9 3.8 6.2 1.1 8.8 3.4 315 10 309 165 -5.2 0.1 -4.8 -5.5 11/09/2006 18:20:00 7 1 10.3 4.2 6.9 1 10.7 4.6 6 1.2 9.1 3 308 10 310 165 -5.3 0 -5 -5.5 11/09/2006 18:30:00 5.7 0.8 7.6 3.4 5.6 0.7 7.6 3.4 5.4 0.9 8 3 319 11 325 165 -5.4 0.1 -5 -5.7 11/09/2006 18:40:00 5.6 0.8 7.6 3.8 5.6 0.8 7.6 3.8 4.9 0.8 7.2 3 311 13 317 165 -5.7 0 -5.5 -5.9 11/09/2006 18:50:00 5.9 1.2 9.9 3.4 5.9 1.2 9.5 3.4 5.2 1 8.4 2.6 305 10 291 165 -5.3 0.2 -5 -5.7 11/09/2006 19:00:00 3.8 0.9 6.8 2.3 3.9 0.9 6.5 1.9 3.8 0.8 6.5 2.3 331 13 336 165 -5.2 0.1 -4.6 -5.3 11/09/2006 19:10:00 4.7 0.7 6.1 2.3 4.8 0.7 6.5 2.3 4.7 0.6 5.7 2.6 323 9 325 165 -5.2 0 -4.8 -5.5 11/09/2006 19:20:00 4.6 1 7.6 2.6 4.7 1 7.6 2.6 4.2 0.8 7.2 2.6 314 13 313 165 -5 0 -4.6 -5.3 11/09/2006 19:30:00 5.5 0.8 7.6 3.4 5.5 0.8 7.6 3 5.2 0.8 8 3.4 314 10 313 165 -5 0 -4.6 -5.3 11/09/2006 19:40:00 5.8 1.1 9.5 3.8 5.9 1 9.1 3.8 5.7 0.9 8 3.4 321 12 312 165 -4.9 0 -4.6 -5 11/09/2006 19:50:00 5.9 0.7 8 4.2 5.9 0.6 8 4.2 5.6 0.6 7.2 3.8 316 9 303 165 -4.9 0 -4.6 -5 11/09/2006 20:00:00 6.8 1.1 10.3 3.4 6.8 1 10.3 3.4 5.8 1.1 8.8 3.4 304 10 302 165 -5 0 -4.6 -5.3 11/09/2006 20:10:00 8.2 1.3 11.5 4.9 8.2 1.3 11.8 4.9 7.1 1.2 11.1 4.9 307 12 300 165 -5 0 -4.6 -5.3 11/09/2006 20:20:00 8.1 1.2 10.7 4.6 8 1.2 10.3 4.9 7.2 1.3 11.1 3.8 313 10 310 165 -5.1 0.1 -4.6 -5.3 11/09/2006 20:30:00 7.7 1.4 11.1 4.2 7.6 1.4 11.1 4.6 6.6 1.4 10.3 3.8 310 11 303 165 -5.2 0 -5 -5.5 11/09/2006 20:40:00 6.1 1.2 9.9 2.6 6.1 1.1 9.9 3 5.7 1.1 8.4 2.6 323 14 296 165 -5.3 0 -5 -5.5 11/09/2006 20:50:00 6.1 1 9.9 3 6.2 0.9 9.5 3.8 5.8 0.9 9.1 3.4 317 17 297 165 -5.3 0 -5 -5.5 11/09/2006 21:00:00 6.9 1 9.9 4.2 6.9 1 9.5 3.8 6.5 1 9.5 4.2 321 13 304 165 -5.1 0 -4.8 -5.3 11/09/2006 21:10:00 7.7 1.3 11.8 4.9 7.7 1.3 11.5 4.9 6.9 1.2 11.5 4.2 307 13 297 165 -5 0 -4.6 -5.3 11/09/2006 21:20:00 10 1.3 14.1 6.8 9.9 1.3 14.9 6.5 8.4 1.5 12.2 5.3 307 12 323 165 -5 0 -4.6 -5.3 11/09/2006 21:30:00 11 1.3 14.5 8.4 11 1.2 14.1 8 8.6 1.3 13.3 6.1 303 9 289 165 -5 0 -4.6 -5.3 11/09/2006 21:40:00 12.1 1.3 16.1 8.8 12.1 1.3 16.1 9.1 9.6 1.3 14.1 6.5 304 8 301 165 -5 0 -4.6 -5.3 11/09/2006 21:50:00 12 1.1 15.3 9.1 11.9 1 14.9 9.1 9.6 1.4 13.7 5.7 305 8 307 165 -5.2 0.1 -4.6 -5.3 11/09/2006 22:00:00 11.9 1.3 16.1 8.8 11.8 1.3 15.3 8.8 10.2 1.5 14.5 6.1 308 8 295 165 -5.2 0.1 -4.8 -5.3 11/09/2006 22:10:00 12.3 1.5 16.1 8 12.1 1.5 16.1 8 10.7 1.6 16.1 6.1 310 6 305 165 -5.1 0 -4.8 -5.3 11/09/2006 22:20:00 12.4 1.3 15.3 8.8 12.2 1.3 15.3 8.4 11 1.4 14.1 6.1 310 7 308 165 -5.1 0 -4.8 -5.3 11/09/2006 22:30:00 13.1 1.5 16.8 8.8 12.8 1.4 16.1 8.8 11.8 1.5 16.1 7.2 312 6 302 165 -4.9 0 -4.6 -5 11/09/2006 22:40:00 13.9 1.5 17.2 10.3 13.7 1.5 16.8 10.3 12.3 1.5 16.1 7.6 310 5 313 165 -5 0 -4.6 -5.3 11/09/2006 22:50:00 15.7 1.1 18.3 12.6 15.5 1.1 18.7 12.6 13.4 1.5 17.2 8.4 309 5 302 165 -4.9 0 -4.6 -5 11/09/2006 23:00:00 15.4 1.1 17.6 11.8 15.2 1.2 17.6 11.5 13.7 1.5 16.8 9.5 310 5 309 165 -5 0 -4.6 -5.3 11/09/2006 23:10:00 14.3 1.1 17.9 10.3 14.1 1.2 17.6 10.3 12.7 1.4 16.1 8 310 5 305 165 -5 0 -4.6 -5.3 11/09/2006 23:20:00 14.5 1.5 17.9 10.3 14.4 1.5 17.6 10.7 12.5 1.6 16.4 7.6 308 6 302 165 -5 0 -4.6 -5.3 11/09/2006 23:30:00 14.1 1.1 16.8 10.3 14 1.1 16.8 9.9 12.5 1.5 16.1 8 309 6 312 165 -5 0 -4.6 -5.3 11/09/2006 23:40:00 14.6 1.2 17.2 11.5 14.5 1.2 17.2 11.1 12.2 1.7 16.4 8.8 307 8 305 165 -5 0 -4.6 -5 11/09/2006 23:50:00 14.8 1.6 18.7 11.1 14.6 1.6 18.3 10.7 12.3 1.7 17.2 7.6 306 7 303 165 -4.9 0 -4.6 -5 11/10/2006 00:00:00 15.4 1.3 19.5 11.5 15.2 1.3 18.7 11.5 13.2 1.5 17.9 9.1 308 6 301 165 -4.9 0 -4.6 -5 11/10/2006 00:10:00 14.6 1.2 17.9 10.7 14.4 1.2 17.9 10.3 12.4 1.6 16.1 8.4 307 8 307 165 -4.8 0 -4.6 -5 11/10/2006 00:20:00 15.1 1.5 20.6 11.5 14.9 1.5 20.2 11.5 12.1 1.8 18.3 8 304 7 310 165 -4.8 0 -4.4 -5 11/10/2006 00:30:00 15 1.7 19.1 11.1 14.8 1.7 19.1 10.7 12.8 2 18.7 8.4 308 8 307 165 -4.8 0 -4.6 -5 11/10/2006 00:40:00 14.6 1.5 19.9 11.1 14.5 1.5 19.9 11.1 11.7 1.7 17.2 8 304 8 304 165 -4.8 0 -4.4 -5 11/10/2006 00:50:00 13.4 1.5 17.9 9.9 13.3 1.5 17.9 9.5 11.4 1.6 17.2 8 308 8 313 165 -4.8 0 -4.6 -5 11/10/2006 01:00:00 13.1 1.7 17.6 9.1 13 1.7 17.9 9.5 10.9 1.7 16.4 7.2 305 8 289 165 -4.7 0.1 -4.4 -5 11/10/2006 01:10:00 13.7 1.5 19.5 9.5 13.5 1.5 18.7 9.5 11.4 1.6 16.4 7.6 306 7 296 165 -4.5 0 -4.4 -4.6 11/10/2006 01:20:00 14.3 1.7 18.7 9.9 14.1 1.7 18.7 9.5 11.7 2.3 18.3 6.5 305 7 310 165 -4.7 0 -4.4 -4.8 11/10/2006 01:30:00 13.2 1.7 19.1 9.5 13.1 1.7 18.7 9.5 11.5 1.7 16.8 7.2 307 12 296 165 -4.5 0 -4.2 -4.6 11/10/2006 01:40:00 12.7 1.7 18.7 8 12.5 1.7 18.7 8 10.5 1.9 16.4 6.5 304 9 295 165 -4.4 0 -3.9 -4.6 11/10/2006 01:50:00 12 1.8 17.9 7.6 11.8 1.8 17.6 7.2 10.7 1.9 16.4 6.1 310 12 291 165 -4.3 0 -4.2 -4.6 11/10/2006 02:00:00 11.4 1.6 15.6 7.2 11.3 1.5 15.3 6.8 10.2 1.4 13.7 6.8 312 12 295 165 -4.3 0 -3.9 -4.4 11/10/2006 02:10:00 11.5 1.7 17.6 6.8 11.4 1.7 16.8 6.1 10 1.6 16.8 6.1 310 9 305 165 -4.3 0 -3.9 -4.4 11/10/2006 02:20:00 14.2 1.7 20.2 9.1 14 1.7 19.1 9.5 11.8 1.9 16.8 8 305 10 301 165 -4.3 0 -3.9 -4.6 11/10/2006 02:30:00 14.6 1.5 20.2 11.1 14.4 1.5 20.6 10.7 12.5 1.7 17.2 7.2 307 8 296 165 -4.4 0 -3.9 -4.6 11/10/2006 02:40:00 14.8 1.6 19.1 9.9 14.6 1.6 18.7 9.5 13.2 1.7 17.9 9.1 309 9 287 165 -4.4 0 -4.2 -4.6 11/10/2006 02:50:00 14.4 1.6 19.1 11.5 14.2 1.6 19.1 11.1 13 1.7 17.2 8.4 309 8 304 165 -4.4 0 -3.9 -4.6 11/10/2006 03:00:00 14.2 1.5 18.3 8 14.1 1.5 17.9 7.6 12.7 1.7 17.6 8 309 9 303 165 -4.5 0 -4.2 -4.6 11/10/2006 03:10:00 14.2 1.4 18.7 10.7 14 1.5 18.7 10.3 13 1.6 19.9 9.1 314 10 313 165 -4.4 0 -4.2 -4.6 11/10/2006 03:20:00 14.9 2 21 11.1 14.7 2 20.6 11.1 13.6 2.3 20.2 8 313 10 308 165 -4.3 0 -3.9 -4.4 11/10/2006 03:30:00 15.9 1.7 20.2 11.5 15.7 1.7 19.9 11.5 14.5 1.7 18.7 10.3 312 9 298 165 -4.2 0 -3.9 -4.4 11/10/2006 03:40:00 15.8 1.8 20.6 11.8 15.6 1.8 20.6 11.5 14.5 2 20.2 8.4 313 8 298 165 -4 0 -3.9 -4.2 11/10/2006 03:50:00 14.8 1.6 19.5 11.1 14.6 1.6 20.2 11.1 13.5 1.8 18.3 8.8 311 9 321 165 -3.9 0 -3.5 -4.2 11/10/2006 04:00:00 15.4 2 22.6 10.3 15.2 2 22.1 10.3 14.3 1.9 19.9 10.3 314 10 310 165 -3.9 0 -3.5 -3.9 11/10/2006 04:10:00 14.5 1.4 18.7 11.1 14.3 1.5 19.1 10.7 13.9 1.5 18.3 9.5 317 8 298 165 -3.9 0 -3.5 -3.9 11/10/2006 04:20:00 15 1.5 19.5 11.5 14.8 1.5 19.1 11.5 14.1 1.7 19.1 9.5 315 7 318 165 -3.9 0 -3.5 -4.2 11/10/2006 04:30:00 15.3 1.3 19.1 11.5 15.1 1.3 18.7 11.1 14.7 1.6 18.3 9.1 314 7 312 165 -4.2 0.1 -3.5 -4.4 11/10/2006 04:40:00 16.2 1.3 20.2 13 16 1.2 19.9 13 15.6 1.6 20.6 11.5 315 8 302 165 -4.3 0 -4.2 -4.6 11/10/2006 04:50:00 17.7 1.5 21.4 12.2 17.5 1.5 21.4 12.2 17.4 1.7 21 12.6 316 7 307 165 -4.5 0 -4.2 -4.6 11/10/2006 05:00:00 17.9 1.5 21.8 13.3 17.7 1.5 21.4 13 17.4 1.5 21.8 12.2 315 8 315 165 -4.5 0 -4.2 -4.6 11/10/2006 05:10:00 17.3 1.3 21 13.3 17.1 1.3 21 13.7 16.7 1.6 20.6 12.2 315 8 318 165 -4.4 0 -4.2 -4.6 11/10/2006 05:20:00 16.8 1.5 21 13 16.6 1.5 21 12.6 16.5 1.8 21 11.1 319 7 316 165 -4.3 0 -3.9 -4.6 11/10/2006 05:30:00 16.6 1.6 21 11.1 16.4 1.6 20.6 10.7 16 1.7 20.6 12.2 317 9 333 165 -4.3 0 -3.9 -4.4 11/10/2006 05:40:00 17.7 1.6 21.8 12.6 17.6 1.6 21.4 12.6 16.5 1.8 20.6 12.2 312 7 310 165 -4.2 0 -3.9 -4.4 11/10/2006 05:50:00 16.9 1.4 21.4 12.6 16.8 1.4 21 12.2 16.3 1.7 21 11.8 313 7 313 165 -4.2 0 -3.7 -4.4 11/10/2006 06:00:00 17.1 1.6 22.6 12.2 16.9 1.6 22.6 11.8 15.9 1.6 21.8 11.5 313 8 314 165 -4.2 0 -3.7 -4.4 11/10/2006 06:10:00 16.9 1.3 20.2 13.3 16.8 1.3 20.2 13 16.1 1.4 19.5 12.2 314 9 303 165 -4.3 0 -3.9 -4.4 11/10/2006 06:20:00 18.3 1.3 22.6 14.9 18.2 1.3 22.1 14.5 17.2 1.5 21.8 13.3 310 6 290 165 -4.4 0 -3.9 -4.6 11/10/2006 06:30:00 19 1.1 21.4 16.1 18.9 1.1 21.4 15.6 18 1.4 21.8 13.7 311 6 308 165 -4.7 0.1 -4.2 -4.8 11/10/2006 06:40:00 18.5 1.3 22.1 14.1 18.4 1.3 21.8 14.1 17.3 1.5 20.6 13.3 310 6 302 165 -4.8 0 -4.6 -5 11/10/2006 06:50:00 18.8 1.3 22.6 14.1 18.7 1.3 22.1 14.5 17.6 1.5 21 12.6 308 6 301 165 -4.8 0 -4.6 -5 11/10/2006 07:00:00 17.3 1.1 19.9 13.3 17.2 1.2 19.5 13.3 15.8 1.4 19.5 11.5 306 6 292 165 -4.9 0 -4.6 -5 11/10/2006 07:10:00 18.7 1.7 22.1 14.5 18.6 1.7 21.8 14.1 17.8 2 21.8 13 308 5 310 165 -5 0 -4.8 -5.3 11/10/2006 07:20:00 19 1.5 22.9 14.5 19 1.6 22.6 14.9 17.6 1.9 22.1 12.6 305 7 294 165 -5 0 -4.8 -5.3 11/10/2006 07:30:00 19.4 2.1 24 14.5 19.3 2.1 24 13.7 18.2 2 24.8 12.2 307 6 300 165 -5.1 0 -4.8 -5.3 11/10/2006 07:40:00 19 1.5 22.9 14.5 18.9 1.5 22.6 14.1 18 1.7 22.6 12.2 308 5 302 165 -5 0 -4.8 -5.3 11/10/2006 07:50:00 18.9 1.3 22.6 15.3 18.8 1.3 22.6 15.3 17.9 1.7 22.9 13.3 309 7 319 165 -5 0 -4.8 -5.3 11/10/2006 08:00:00 19.8 1.3 23.7 15.6 19.7 1.4 23.7 15.6 18.5 1.6 22.9 13.3 308 7 304 165 -5 0 -4.6 -5.3 11/10/2006 08:10:00 19.2 1.5 23.3 15.3 19 1.5 23.3 14.9 18.1 1.6 21.8 13 309 8 276 165 -5 0 -4.6 -5.3 11/10/2006 08:20:00 18.4 1.3 22.6 14.9 18.3 1.2 22.1 15.3 18.3 1.3 21 14.9 314 6 307 165 -5 0 -4.6 -5 11/10/2006 08:30:00 18.9 1.4 22.9 14.9 18.7 1.4 22.6 14.9 18.2 1.4 22.6 13.7 311 8 308 165 -5 0 -4.6 -5 11/10/2006 08:40:00 18.4 1.3 21.8 15.3 18.3 1.3 21.4 14.9 17.4 1.5 22.1 13.7 311 9 302 165 -5 0 -4.8 -5.3 11/10/2006 08:50:00 20.4 2.3 25.2 13 20.3 2.3 25.2 13.3 19.3 2.3 23.7 13.3 308 7 304 165 -5 0 -4.8 -5 11/10/2006 09:00:00 21.5 1.3 25.2 17.2 21.5 1.3 25.2 17.6 20.2 1.8 23.7 15.3 306 6 300 165 -4.9 0 -4.6 -5 11/10/2006 09:10:00 22.2 1.7 26.3 17.2 22.1 1.7 26.3 17.6 20.5 1.8 25.2 14.5 305 7 305 165 -4.9 0 -4.6 -5 11/10/2006 09:20:00 23.1 1.5 26.3 16.8 23 1.5 26.3 16.8 21.4 2.1 26 15.3 305 7 305 165 -5 0 -4.6 -5 11/10/2006 09:30:00 22.9 1.9 28.3 16.1 22.8 1.9 27.9 16.4 21.6 2.2 27.9 16.1 306 7 297 165 -5 0 -4.6 -5.3 11/10/2006 09:40:00 23.9 1.8 27.9 19.1 23.9 1.8 27.9 19.1 22.5 2.2 27.9 16.4 305 8 301 165 -5.2 0 -5 -5.5 11/10/2006 09:50:00 23.8 2.1 29.1 17.6 23.8 2.1 29.1 16.8 22.6 2.5 27.9 14.9 307 7 301 165 -5.3 0 -5 -5.5 11/10/2006 10:00:00 24.7 1.7 28.7 19.5 24.6 1.7 28.7 18.7 23.2 2 27.9 17.2 305 8 302 165 -5.2 0 -5 -5.3 11/10/2006 10:10:00 25.1 1.7 29.4 20.2 25.1 1.8 29.8 20.6 23.7 2.2 28.7 17.9 305 8 312 165 -5.2 0 -5 -5.3 11/10/2006 10:20:00 24.8 1.8 28.7 19.1 24.7 1.9 28.7 19.1 23.6 2.3 28.7 16.8 305 7 307 165 -5.2 0 -5 -5.5 11/10/2006 10:30:00 25.2 1.7 29.8 19.5 25.1 1.8 29.4 19.1 24.3 2.1 29.1 18.7 307 7 308 165 -5.1 0 -5 -5.3 11/10/2006 10:40:00 22.3 1.7 27.5 17.6 22.2 1.7 27.9 17.2 21.4 2 27.1 15.6 310 9 317 165 -5 0 -4.8 -5.3 11/10/2006 10:50:00 23.9 2.1 29.1 18.3 23.8 2.2 29.1 17.9 22.4 2.2 28.3 16.4 306 8 305 165 -5 0 -4.8 -5.3 11/10/2006 11:00:00 25.8 1.5 29.8 20.6 25.8 1.6 29.4 20.6 24 1.9 28.3 18.7 302 6 308 165 -4.9 0 -4.6 -5 11/10/2006 11:10:00 26.9 1.8 30.9 20.6 26.9 1.9 30.9 20.6 25 2.4 30.2 17.6 301 7 297 165 -4.8 0 -4.6 -5 11/10/2006 11:20:00 28.1 1.5 30.9 24 28.2 1.5 31.3 24.4 27 2.1 31.3 20.2 303 6 304 165 -4.8 0 -4.6 -4.8 11/10/2006 11:30:00 28.4 1.7 32.9 24 28.4 1.8 32.9 23.7 27.1 2 31.3 21 303 6 300 165 -4.7 0 -4.6 -4.8 11/10/2006 11:40:00 27.9 1.8 32.9 21.8 27.9 1.8 32.9 21.8 26.5 2.1 32.4 20.6 303 5 309 165 -4.8 0 -4.6 -5 11/10/2006 11:50:00 28.4 2.1 34 22.9 28.5 2.1 34.4 23.3 26.9 2.4 34 19.9 301 7 302 165 -4.7 0 -4.4 -4.8 11/10/2006 12:00:00 28 2.1 33.2 21 28 2.2 33.2 21 25.5 2.5 31.3 17.9 297 9 311 165 -4.7 0 -4.6 -4.8 11/10/2006 12:10:00 28.7 2.5 34.4 21.4 28.7 2.6 34.8 21 26.6 2.9 32.1 15.3 301 8 300 165 -4.5 0.1 -4.2 -4.6 11/10/2006 12:20:00 29.5 2 35.5 24 29.5 2 35.9 24 27.5 2.4 34 21 300 7 301 165 -4.5 0 -4.4 -4.6 11/10/2006 12:30:00 29.6 2.5 35.9 22.6 29.6 2.5 35.9 22.1 26.6 2.9 33.6 17.2 296 8 261 165 -4.3 0.1 -3.9 -4.6 11/10/2006 12:40:00 27.5 2.5 35.2 20.2 27.4 2.4 35.9 20.6 24.6 2.5 31.8 16.4 301 10 280 165 -3.8 0.2 -3.3 -4.4 11/10/2006 12:50:00 24.3 2.4 30.2 17.6 24.1 2.5 30.9 17.6 20.7 2.6 30.2 14.1 301 9 296 165 -3.1 0.1 -2.8 -3.5 11/10/2006 13:00:00 21.2 2.6 26.8 13.3 20.9 2.5 26 13.7 18.9 2.7 26 11.1 309 15 306 165 -2.9 0.2 -2.4 -3.5 11/10/2006 13:10:00 25 3.1 33.6 17.2 24.9 3.1 32.4 16.1 21.1 3.1 28.3 13.7 295 9 293 165 -3.8 0.2 -3 -4.4 11/10/2006 13:20:00 24.2 2.6 30.2 17.2 24.1 2.6 30.2 16.4 20.3 2.5 27.1 12.6 295 9 290 165 -3.9 0.1 -3.5 -4.4 11/10/2006 13:30:00 24.3 2.2 29.1 19.1 24.2 2.3 29.1 18.7 20.9 2.2 26.3 14.9 294 9 297 165 -4 0 -3.7 -4.4 11/10/2006 13:40:00 21 3.5 28.7 12.6 20.8 3.5 27.9 12.6 18.1 3.3 26.8 9.9 296 13 284 165 -3.9 0 -3.5 -4.2 11/10/2006 13:50:00 19.1 3.1 26 10.3 18.9 3.1 26 9.9 15.9 2.9 23.3 8.4 299 12 316 165 -3.3 0.2 -2.8 -3.5 11/10/2006 14:00:00 21.5 2.1 26.8 15.6 21.3 2 26 15.3 17.8 2.3 24.4 11.5 294 10 302 165 -3.3 0 -3 -3.5 11/10/2006 14:10:00 21.5 2.4 27.5 14.5 21.2 2.3 27.1 14.9 17.8 2.3 22.9 11.8 295 8 313 165 -3.4 0 -3 -3.5 11/10/2006 14:20:00 22.9 2.6 27.9 15.6 22.8 2.6 27.5 15.3 19.5 2.7 27.1 12.6 291 9 285 165 -3.8 0 -3.3 -3.9 11/10/2006 14:30:00 23.7 1.9 27.9 17.6 23.6 2 27.9 17.6 20.3 2.7 27.1 14.1 289 9 286 165 -3.8 0 -3.5 -3.9 11/10/2006 14:40:00 22.3 2.2 27.5 15.6 22.2 2.2 27.1 15.6 19 2.4 26.8 13 293 9 291 165 -3.5 0 -3.3 -3.5 11/10/2006 14:50:00 21.6 2 28.7 16.4 21.6 2 28.3 16.1 18.9 2.4 25.2 13.3 292 8 295 165 -3.7 0.1 -3.5 -3.9 11/10/2006 15:00:00 19.8 2 24.8 13.3 19.8 2.1 25.2 14.1 17.2 2.2 22.6 10.3 293 8 299 165 -3.7 0 -3.5 -3.9 11/10/2006 15:10:00 21.4 2.2 26 13 21.3 2.3 26.3 13.7 18.7 2.4 24.4 11.8 293 9 294 165 -4 0 -3.7 -4.2 11/10/2006 15:20:00 21.6 2.2 27.1 14.1 21.6 2.2 26.8 14.1 18.6 2.2 24 11.5 295 8 297 165 -4 0 -3.7 -4.2 11/10/2006 15:30:00 19.5 2.6 25.2 11.8 19.4 2.6 25.2 11.5 16.6 2.6 23.7 8.4 295 9 298 165 -3.6 0.1 -3.3 -3.9 11/10/2006 15:40:00 18.5 2.3 24 11.8 18.4 2.3 24.4 11.8 15.3 2.1 19.9 9.1 297 10 297 165 -3.2 0.1 -2.8 -3.5 11/10/2006 15:50:00 14.2 2.7 24.4 9.1 14 2.7 24 8.8 12.7 2 22.1 8.8 310 16 307 165 -2.4 0.3 -1.9 -3 11/10/2006 16:00:00 14.2 1.9 19.1 8.8 14.1 1.9 18.7 8.8 12.5 1.7 17.2 7.6 306 9 303 165 -2 0.1 -1.7 -2.4 11/10/2006 16:10:00 15.8 1.6 19.9 11.8 15.8 1.6 19.9 11.5 12.8 1.7 18.3 8.8 293 8 296 165 -2.7 0.1 -2.1 -3 11/10/2006 16:20:00 16 1.7 19.9 10.3 15.9 1.7 19.1 10.7 13.2 2 19.9 8 292 8 289 165 -2.8 0 -2.6 -3 11/10/2006 16:30:00 13.6 2.1 18.3 9.5 13.6 2 17.9 9.5 11.6 1.7 18.3 8 299 13 292 165 -2.6 0.1 -2.1 -2.8 11/10/2006 16:40:00 11.7 2 16.1 7.2 11.6 1.9 16.1 7.2 10.5 1.9 16.1 6.1 310 11 315 165 -2 0.3 -1.4 -2.6 11/10/2006 16:50:00 12.5 1.3 15.6 9.5 12.5 1.2 15.6 9.5 10.9 1.6 16.1 7.6 305 12 284 165 -1.6 0 -1.4 -1.9 11/10/2006 17:00:00 11.7 1.3 16.8 7.2 11.6 1.2 16.8 6.8 10.3 1.5 14.5 6.8 307 11 311 165 -1.6 0 -1.4 -1.9 11/10/2006 17:10:00 11.9 1.5 15.6 8 11.8 1.5 15.6 8 9.8 1.3 14.9 6.1 299 10 295 165 -1.4 0.1 -1 -1.9 11/10/2006 17:20:00 11.3 1.7 16.4 7.2 11.3 1.7 16.4 7.2 9.7 1.5 14.1 5.7 302 14 292 165 -1.7 0 -1.4 -1.9 11/10/2006 17:30:00 10.4 1.7 13.7 5.7 10.4 1.7 14.1 5.7 9.2 1.7 13.3 4.9 306 9 305 165 -1.6 0.1 -1.2 -1.9 11/10/2006 17:40:00 9.6 1.3 13.3 6.8 9.6 1.3 13.3 6.5 8.2 1.2 13 5.7 302 10 297 165 -1.2 0.2 -0.3 -1.4 11/10/2006 17:50:00 9.2 1.5 13.3 6.1 9.1 1.5 13 6.1 8.6 1.5 11.8 5.3 312 10 302 165 -0.7 0.3 -0.1 -1.2 11/10/2006 18:00:00 9.2 1.5 13 6.1 9.1 1.5 13 6.1 8.6 1.2 11.5 6.1 315 13 300 165 -1 0.1 -0.5 -1.2 11/10/2006 18:10:00 9.4 1.2 13 6.1 9.3 1.2 13 6.5 8.9 1.2 11.5 5.7 316 11 309 165 -0.3 0.1 -0.1 -0.8 11/10/2006 18:20:00 8.3 1.2 12.2 5.7 8.2 1.2 11.8 5.7 8 1.4 12.2 4.9 318 11 314 165 -0.3 0 -0.1 -0.5 11/10/2006 18:30:00 7 1.5 11.1 3.8 6.9 1.5 11.1 4.2 6.8 1.3 11.5 4.2 322 15 318 165 -0.1 0 0.2 -0.3 11/10/2006 18:40:00 6.9 1.3 10.3 3.8 6.9 1.2 9.9 3.8 6.2 1.2 9.5 2.6 308 12 306 165 0.3 0.1 0.7 0.2 11/10/2006 18:50:00 8.2 1.2 11.1 4.2 8.2 1.2 11.1 4.9 7 1.1 10.3 4.2 303 10 296 165 -0.2 0.3 0.7 -0.5 11/10/2006 19:00:00 8.4 1.2 11.5 5.7 8.3 1.2 11.5 5.3 7.5 1.3 11.1 4.2 307 15 302 165 -0.2 0.1 0.2 -0.5 11/10/2006 19:10:00 8.1 1.2 12.2 4.9 7.9 1.2 12.2 4.9 7.6 1.2 11.1 4.6 322 11 330 165 0.2 0.3 0.9 -0.3 11/10/2006 19:20:00 7.5 1.1 10.3 4.2 7.4 1 10.7 4.6 6.9 1 9.1 3.8 316 11 325 165 0.5 0.1 0.9 0.2 11/10/2006 19:30:00 7 1.4 9.9 1.9 7 1.3 9.5 1.9 6.4 1.5 9.5 1.1 316 14 321 165 0.7 0.1 1.1 0.4 11/10/2006 19:40:00 6.3 1.1 9.1 4.2 6.2 1 9.1 4.2 6.2 1.2 10.3 3.4 324 12 328 165 0.8 0.3 1.4 0.2 11/10/2006 19:50:00 6.6 1.3 9.9 3.8 6.4 1.3 9.9 3.4 6.5 1.3 9.9 3 337 15 333 165 1.4 0 1.6 1.4 11/10/2006 20:00:00 7.2 1.7 13.3 4.6 6.9 1.5 13.7 3.8 6.8 1.5 11.8 3.8 334 20 340 165 1.5 0.2 1.8 1.4 11/10/2006 20:10:00 6.5 1.8 11.8 2.6 6.2 1.6 11.5 3 6.2 1.5 10.7 2.6 340 22 6 165 1.9 0.1 2.3 1.6 11/10/2006 20:20:00 6.6 1.4 9.5 2.6 5.9 1.4 9.1 2.3 6.2 1.3 9.5 3.8 349 17 3 165 2 0.1 2.6 1.6 11/10/2006 20:30:00 6.9 1.7 11.1 3.4 6.1 1.2 9.9 3 6.5 1.5 10.3 3.8 348 20 354 165 2.1 0.3 2.8 1.8 11/10/2006 20:40:00 10.9 1.9 16.1 6.5 8.4 1.8 14.1 4.2 10.4 2.1 16.8 6.5 1 10 3 165 3 0.2 3.5 2.6 11/10/2006 20:50:00 10.4 2.3 15.3 5.3 8.2 2.3 14.5 4.2 10.2 2.3 15.6 5.7 4 10 2 165 3.3 0 3.5 3.3 11/10/2006 21:00:00 8.9 1.7 12.2 4.9 8 1.7 11.8 4.2 8.7 1.8 12.2 4.9 11 13 10 165 3.1 0 3.5 2.8 11/10/2006 21:10:00 10.4 2.9 14.9 4.9 8.7 2.3 13.7 4.6 10.4 2.9 15.3 4.9 15 8 12 165 2.9 0.1 3.3 2.6 11/10/2006 21:20:00 11.2 1.6 15.3 6.8 9.2 1.8 14.9 4.9 11 1.7 16.1 6.5 7 11 358 165 2.9 0.2 3.3 2.6 11/10/2006 21:30:00 11.7 1.5 15.3 7.6 9.8 1.9 13.3 5.3 11.8 1.4 15.3 7.6 13 9 8 165 3.3 0 3.5 3.3 11/10/2006 21:40:00 11.1 1.6 15.3 6.5 9.5 2 14.1 4.9 11.1 1.7 15.3 6.1 14 10 357 165 3.5 0.1 3.8 3.3 11/10/2006 21:50:00 9.1 1.7 13.3 4.6 7.8 1.8 13.3 3.8 9 1.7 13.3 4.6 18 15 30 165 3.6 0 3.8 3.5 11/10/2006 22:00:00 9.5 1.7 12.6 4.6 8.7 1.8 12.6 3.4 9.4 1.8 12.6 4.6 18 10 25 165 3.4 0 3.5 3 11/10/2006 22:10:00 10.5 1 13.3 8 8.6 1.5 12.2 4.9 10.2 1.1 13.3 7.2 12 7 18 165 3 0 3.3 2.8 11/10/2006 22:20:00 10.3 1.2 14.1 7.6 8.9 1.7 13.7 5.3 10.2 1.2 13.3 7.6 15 8 12 165 3.2 0 3.5 3 11/10/2006 22:30:00 10.5 1.4 14.1 6.8 9.4 1.7 13.3 5.7 10.4 1.5 13.7 7.2 18 7 17 165 3.2 0 3.3 3 11/10/2006 22:40:00 10.2 1.2 13.3 7.2 9.6 1.4 13.3 5.3 9.9 1.3 13.3 7.2 21 7 32 165 3.4 0.2 3.8 3 11/10/2006 22:50:00 10.4 1.1 14.5 6.8 9.7 1.4 14.5 5.3 10.3 1.2 14.5 6.8 18 8 31 165 3.9 0.1 4.3 3.5 11/10/2006 23:00:00 10.3 1.2 14.1 6.8 9.6 1.5 13.7 5.3 10.2 1.3 14.1 6.5 18 7 23 165 4.1 0 4.3 4 11/10/2006 23:10:00 10.1 1.2 13 6.8 9.6 1.3 13 5.3 10 1.2 13 5.7 19 7 12 165 4.1 0 4.3 4 11/10/2006 23:20:00 9.3 1.2 12.6 6.1 8.9 1.3 11.8 5.7 8.9 1.3 14.1 6.1 23 8 22 165 4 0 4.3 3.8 11/10/2006 23:30:00 10 1.3 13.3 7.2 9.3 1.3 12.6 6.5 9.9 1.2 13 7.6 18 7 14 165 4.1 0 4.3 3.8 11/10/2006 23:40:00 10.3 1.5 14.1 6.8 9.6 1.8 14.5 5.7 10.1 1.6 14.1 6.5 19 7 20 165 4.1 0 4.3 4 11/10/2006 23:50:00 9.2 1.3 12.6 6.1 8 1.5 12.2 4.9 9.1 1.3 13.3 5.7 16 9 7 165 4 0 4.3 3.8 11/11/2006 00:00:00 9.7 1.3 13.3 6.5 8.9 1.5 13 4.6 9.5 1.3 13.3 6.5 19 7 25 165 4 0 4.3 3.8 11/11/2006 00:10:00 10.2 1.4 14.1 6.8 9.2 1.5 13.7 5.7 9.9 1.3 13.7 7.2 17 8 16 165 4.1 0 4.5 4 11/11/2006 00:20:00 10.1 1 13 6.1 9.3 1.3 12.6 4.9 10.1 1.1 12.6 6.8 18 6 25 165 4.1 0 4.5 4.3 11/11/2006 00:30:00 10 1.8 16.4 6.5 7.9 1.6 13 4.6 9.8 1.8 14.9 5.3 9 11 10 165 4.3 0 4.5 4 11/11/2006 00:40:00 10 1.4 14.5 6.8 8.7 1.8 13.3 4.6 9.5 1.6 14.5 5.3 352 9 3 165 3.9 0.3 4.5 3.5 11/11/2006 00:50:00 8.3 2 14.1 4.2 7.4 2.3 12.6 3 8 1.6 12.2 4.2 356 16 351 165 3.2 0.1 3.5 2.8 11/11/2006 01:00:00 7.8 2.1 13 4.2 6.2 2.1 13 2.6 7.5 1.8 11.8 4.2 8 10 23 165 3.6 0.1 4 3.3 11/11/2006 01:10:00 9 1.5 13 5.7 7.1 1.5 10.7 3.8 8.8 1.3 12.2 6.1 8 8 11 165 4.1 0 4.5 3.8 11/11/2006 01:20:00 8.6 1.9 13.3 4.2 6.7 1.7 12.2 2.6 8.2 1.9 13 4.2 4 11 10 165 4.1 0.2 4.5 3.8 11/11/2006 01:30:00 6.2 1.1 9.1 3.8 5.5 1.1 8.4 1.9 5.7 0.9 8.4 3.8 351 12 3 165 3.5 0.2 4.3 3.3 11/11/2006 01:40:00 7.6 1.8 12.2 3.4 6.2 1.8 11.5 3 7.5 1.7 12.2 4.6 1 13 7 165 3.3 0 3.8 3 11/11/2006 01:50:00 8.1 1.4 12.2 4.2 6.7 1.6 11.5 3.4 8 1.2 11.5 4.9 356 11 355 165 3.6 0.1 3.8 3.3 11/11/2006 02:00:00 9.2 1.3 13.3 5.7 7.7 1.7 12.2 4.2 8.9 1.4 13 6.1 360 12 3 165 3.4 0 3.5 3.3 11/11/2006 02:10:00 8.6 1.7 12.6 4.2 6.9 1.9 11.8 3.4 8.5 1.7 13.3 4.9 6 12 16 165 3.6 0 3.8 3.3 11/11/2006 02:20:00 7.2 1.4 12.6 3.8 6.1 1.5 12.2 3 7.3 1.3 12.2 4.9 354 12 353 165 3.1 0.2 3.5 2.8 11/11/2006 02:30:00 6.4 1.1 9.5 3.8 6 1.1 9.1 3.8 6.1 1.1 9.1 3.8 344 10 360 165 2.8 0 3 2.6 11/11/2006 02:40:00 6.3 1.2 10.7 3.4 6 1.2 9.5 3 6 1.1 8.4 3 344 10 338 165 2.7 0 2.8 2.6 11/11/2006 02:50:00 8 1.8 13.7 4.6 6.8 2 12.2 2.6 7.8 1.7 12.6 4.6 355 13 3 165 2.9 0 3.3 2.6 11/11/2006 03:00:00 10.1 1.4 13.7 7.2 8.5 1.4 12.2 4.9 10.1 1.5 14.5 6.5 352 12 3 165 3.5 0.1 3.8 3 11/11/2006 03:10:00 7.5 1.5 11.5 4.2 7.3 1.5 11.1 4.2 7.4 1.4 10.7 3.4 339 9 334 165 2.8 0 3.3 2.6 11/11/2006 03:20:00 9.3 1.2 13.3 6.1 9.3 1.3 13.7 4.9 8.9 1.2 11.8 6.5 336 9 339 165 2.6 0.1 2.8 2.6 11/11/2006 03:30:00 9 1.3 13 6.1 8.8 1.4 13.7 5.7 8.2 1.3 12.6 5.3 336 11 350 165 2.5 0 2.8 2.3 11/11/2006 03:40:00 10.5 1.6 14.5 6.8 10.4 1.6 14.1 6.5 10.4 1.7 15.3 6.8 332 9 327 165 2.3 0 2.6 2.3 11/11/2006 03:50:00 11.2 1.5 14.1 7.2 11 1.5 14.5 7.2 11.2 1.5 15.3 6.8 331 6 340 165 2.2 0 2.6 2.1 11/11/2006 04:00:00 10.3 1.6 14.5 6.5 10.1 1.6 14.9 6.5 10.1 1.7 14.5 6.8 335 9 339 165 2.1 0 2.3 1.8 11/11/2006 04:10:00 11.1 1.4 15.3 7.2 11 1.4 14.5 6.8 11 1.5 14.5 7.2 333 9 334 165 2.2 0 2.6 2.1 11/11/2006 04:20:00 10.6 1.5 15.6 5.3 10.3 1.8 16.1 4.9 10.6 1.3 14.5 6.8 341 9 343 165 2.4 0 2.8 2.3 11/11/2006 04:30:00 10.3 2 14.9 5.3 10.1 2.1 14.5 5.3 10.3 1.7 14.9 6.1 339 10 337 165 2.6 0 2.8 2.3 11/11/2006 04:40:00 8.8 1.6 13 4.6 8.5 1.7 13 4.9 8.7 1.4 12.2 5.3 338 11 338 165 2.6 0.1 2.8 2.3 11/11/2006 04:50:00 10.4 1.4 15.3 6.1 10.2 1.5 14.5 4.9 9.5 1.3 13.7 6.1 330 9 332 165 2.7 0 3 2.6 11/11/2006 05:00:00 9.2 1.7 12.6 4.2 9 1.7 12.6 3.4 8.4 1.5 11.8 4.6 335 10 335 165 2.9 0 3 2.8 11/11/2006 05:10:00 8.7 1.6 12.2 4.6 8.5 1.6 11.8 4.6 7.8 1.6 11.8 3.8 335 9 328 165 2.9 0 3.3 2.8 11/11/2006 05:20:00 7.9 1.5 11.8 4.9 7.7 1.6 11.5 3.8 7.2 1.5 12.2 2.6 339 12 340 165 2.9 0 3 2.6 11/11/2006 05:30:00 8.3 1.3 11.8 5.3 8 1.4 11.8 5.3 7.1 1.4 10.7 4.2 335 10 340 165 2.7 0 3 2.6 11/11/2006 05:40:00 8.3 1.5 12.6 4.2 8.2 1.5 12.2 4.6 7.5 1.4 12.2 4.6 332 9 323 165 2.7 0 2.8 2.6 11/11/2006 05:50:00 8.5 1.2 11.5 5.3 8.3 1.2 11.5 5.3 7.5 1.2 10.7 4.2 328 9 336 165 2.9 0 3 2.6 11/11/2006 06:00:00 7.8 1.5 11.1 3.4 7.7 1.3 11.5 3.8 6.7 1.7 10.7 2.6 324 12 321 165 3.1 0 3.3 2.8 11/11/2006 06:10:00 6.7 1.8 11.5 3.4 6.6 1.8 11.1 3.4 5.3 2.2 10.3 0.7 325 15 330 165 3 0.1 3.5 2.8 11/11/2006 06:20:00 7.3 1.4 11.5 3.8 7.2 1.3 11.1 4.2 6.5 1.3 10.7 3.4 327 12 324 165 3.2 0 3.5 3 11/11/2006 06:30:00 7.1 1.3 10.7 4.2 7 1.3 10.7 4.6 6 1.3 11.1 2.6 321 10 332 165 3.3 0.2 3.8 2.8 11/11/2006 06:40:00 8.3 1.2 10.7 4.9 8.1 1.1 11.1 5.3 7.4 1.1 10.7 4.9 319 9 319 165 2.8 0 3.3 2.6 11/11/2006 06:50:00 9.1 1.2 12.2 5.3 8.9 1.2 12.2 5.7 8.4 1.1 11.8 5.7 322 9 325 165 3 0.1 3.3 2.6 11/11/2006 07:00:00 9.5 1.3 13 6.8 9.4 1.2 13 6.8 8.8 1.5 13 5.7 322 10 332 165 3.5 0.2 4 3.3 11/11/2006 07:10:00 9.9 1 12.2 6.1 9.7 1 12.2 5.7 9.2 1.1 11.8 6.1 320 10 307 165 3.6 0 4 3.5 11/11/2006 07:20:00 10.1 0.9 12.2 7.6 9.9 0.9 12.2 7.2 9.2 0.9 11.5 6.1 314 7 297 165 3.6 0 4 3.5 11/11/2006 07:30:00 9.7 1.3 13 6.1 9.5 1.2 12.6 6.5 8.9 1.1 11.5 5.7 313 9 301 165 3.7 0 3.8 3.5 11/11/2006 07:40:00 9.4 1.3 12.6 4.9 9.2 1.3 12.2 4.9 8.6 1.2 11.5 4.9 314 10 310 165 3.6 0 3.8 3.5 11/11/2006 07:50:00 8.9 1.4 13 5.7 8.7 1.4 13 5.7 8.1 1.3 11.8 5.3 311 10 313 165 3.4 0 3.8 3.3 11/11/2006 08:00:00 8.9 1.2 11.5 5.3 8.8 1.2 11.5 5.7 8 1.2 11.8 4.6 310 11 319 165 3.3 0 3.5 3.3 11/11/2006 08:10:00 8.9 1.4 13.7 4.9 8.8 1.4 13 4.9 7.5 1 10.7 4.9 307 12 304 165 3.3 0 3.5 3 11/11/2006 08:20:00 8 1.3 11.5 3.4 7.8 1.3 11.1 3.4 7.1 1 9.9 4.6 311 13 293 165 3.1 0 3.5 3 11/11/2006 08:30:00 8 1.3 12.2 4.6 7.8 1.2 11.8 4.6 7.2 1.2 11.5 4.2 313 15 306 165 3 0 3.5 2.8 11/11/2006 08:40:00 7.6 1.1 10.3 4.9 7.5 1.1 10.3 4.9 7 1 9.5 4.6 313 12 310 165 3.3 0 3.5 3.3 11/11/2006 08:50:00 7.2 1.5 10.7 3.4 7.2 1.5 10.7 3.4 6.2 1.2 9.9 3 302 14 292 165 3.2 0 3.5 3 11/11/2006 09:00:00 8.7 1.6 11.8 3.8 8.7 1.6 11.8 4.2 7.2 1.5 11.5 3.8 293 12 295 165 3.3 0 3.5 3.3 11/11/2006 09:10:00 8.4 1.1 12.2 5.7 8.3 1.1 12.2 5.7 7.9 1.2 11.8 4.9 316 15 336 165 3.6 0.1 4 3.3 11/11/2006 09:20:00 8.6 1.7 13 4.2 8.5 1.7 13 4.2 7.3 1.3 10.7 4.2 304 15 260 165 3.8 0 4.3 3.5 11/11/2006 09:30:00 8.2 1.4 11.5 3.8 8.1 1.3 10.7 4.6 7 1.1 9.9 3.8 306 13 296 165 3.9 0 4.3 3.8 11/11/2006 09:40:00 6.7 1.2 9.9 3.4 6.7 1.2 9.5 3.4 5.9 1.2 9.9 3 307 17 287 165 4.3 0 4.5 4 11/11/2006 09:50:00 11.2 2 16.4 3.4 11.1 1.9 16.1 3.4 9.1 2.1 15.3 2.6 291 10 310 165 4.1 0.2 4.5 3.5 11/11/2006 10:00:00 12.6 1.7 16.8 8 12.5 1.7 15.6 7.6 10.4 1.9 14.9 5.7 292 6 300 165 3.6 0.1 3.8 3.3 11/11/2006 10:10:00 10.7 1.9 14.9 5.7 10.6 1.9 14.9 6.1 8.8 1.7 13.3 4.6 292 8 289 165 3.6 0.1 3.8 3 11/11/2006 10:20:00 10.3 1.7 13.7 5.7 10.2 1.6 13.7 5.7 8.3 1.7 13.3 4.2 294 9 292 165 4 0.3 4.5 3.3 11/11/2006 10:30:00 12 1.6 16.1 6.8 12 1.5 15.6 7.2 10.3 1.7 16.8 6.1 291 5 290 165 4.3 0.2 4.8 3.8 11/11/2006 10:40:00 12.6 1.1 15.3 9.5 12.6 1.1 15.3 9.1 9.9 1.5 14.1 6.8 294 5 295 165 4.1 0 4.5 3.8 11/11/2006 10:50:00 11.8 1.5 14.9 7.6 11.7 1.5 14.9 8 8.9 1.2 12.2 5.7 299 6 295 165 4.3 0.1 4.8 3.8 11/11/2006 11:00:00 13.1 1.2 15.3 9.9 13 1.2 15.3 9.5 10.3 1.4 14.5 7.2 303 6 299 165 4.6 0.1 5 4.3 11/11/2006 11:10:00 13.4 1.2 16.1 8.8 13.3 1.2 15.6 8.4 10.7 1.1 14.1 7.6 304 6 307 165 5 0 5.2 4.8 11/11/2006 11:20:00 13 1.1 15.3 9.5 12.8 1.1 15.3 9.9 10.2 1.2 13.3 7.6 303 6 300 165 5.1 0 5.2 4.5 11/11/2006 11:30:00 12.5 1 14.9 9.5 12.3 1.1 14.5 9.1 9.9 1 13 7.6 303 6 301 165 5.2 0 5.5 5 11/11/2006 11:40:00 12.5 0.9 14.1 9.9 12.4 0.9 14.1 9.9 10.1 1.1 13.3 7.6 305 5 303 165 5.2 0 5.5 5.2 11/11/2006 11:50:00 12.5 1.1 14.9 9.1 12.4 1.2 14.9 8.8 10 1.2 13 7.2 306 6 302 165 5.4 0 5.7 5.2 11/11/2006 12:00:00 12.8 0.9 14.5 9.9 12.7 0.9 14.5 9.9 10.8 1.2 13.7 7.6 308 5 305 165 5.6 0 5.7 5.5 11/11/2006 12:10:00 12.6 0.6 14.1 10.7 12.5 0.6 13.7 10.7 10.9 0.8 14.1 9.1 308 4 314 165 5.7 0 6 5.5 11/11/2006 12:20:00 12.5 0.7 14.1 10.7 12.5 0.7 13.7 10.3 10.5 1 12.6 7.6 308 4 308 165 5.9 0 6.2 5.7 11/11/2006 12:30:00 12.2 0.8 14.1 9.9 12.1 0.8 14.1 9.9 10.1 1.1 12.6 6.8 307 4 304 165 6.1 0 6.2 5.7 11/11/2006 12:40:00 12 0.7 13.7 9.9 11.9 0.7 13.3 9.9 9.8 1 12.6 7.6 307 3 304 165 6.1 0 6.2 6 11/11/2006 12:50:00 10.7 0.6 12.6 8.8 10.6 0.6 12.2 8.4 9 0.7 11.1 7.2 308 3 310 165 6.2 0.1 6.7 6 11/11/2006 13:00:00 9.2 1 11.8 6.8 9 1 11.5 6.5 8.7 1 11.1 6.1 316 5 311 165 6.7 0.2 7 6.2 11/11/2006 13:10:00 7.1 1 9.1 4.9 6.9 0.9 9.1 4.9 6.4 1 8.8 3.8 312 6 314 165 7.2 0.1 8 7 11/11/2006 13:20:00 6.1 0.8 8 4.2 5.9 0.7 7.6 4.2 5.3 1 7.6 2.6 312 7 310 165 7.5 0.1 7.8 7.3 11/11/2006 13:30:00 7.1 0.6 8.4 5.3 6.8 0.6 8 4.6 5.8 0.8 8 3.8 306 5 301 165 7.2 0 7.8 7 11/11/2006 13:40:00 5 1.1 6.8 2.6 5.1 1 6.8 3 4.3 1.1 8 1.5 295 12 308 165 7.5 0.3 8.5 7 11/11/2006 13:50:00 3.3 0.7 6.1 1.5 3.4 0.7 5.7 1.9 2.7 0.6 4.6 1.1 302 9 307 165 8.5 0.1 9 8 11/11/2006 14:00:00 3.3 1 5.3 0.4 3.5 0.9 5.3 0.4 3 0.7 4.9 1.5 290 12 298 165 8.2 0.3 8.8 7.5 11/11/2006 14:10:00 3.5 1.1 6.1 1.5 3.7 1.1 6.1 1.5 3.4 1.2 6.1 0.7 287 14 288 165 7.7 0.3 8 7 11/11/2006 14:20:00 3.9 0.7 5.7 1.9 4 0.6 5.7 2.6 3.8 0.7 5.7 2.3 287 8 282 165 7.1 0 7.5 7 11/11/2006 14:30:00 2.5 0.8 4.2 0.7 2.7 0.7 4.6 0.7 2.3 0.6 4.2 0.7 282 27 297 165 7.3 0.3 8.3 7 11/11/2006 14:40:00 1.8 0.7 3.4 0.4 1.9 0.7 3.4 0.4 2.1 0.7 4.2 0.4 237 47 290 165 7.7 0 8.3 7.5 11/11/2006 14:50:00 0.9 0.4 1.9 0.4 1.1 0.6 2.6 0.4 1.2 0.6 2.6 0.4 220 39 269 165 8.1 0.1 8.5 7.5 11/11/2006 15:00:00 1.5 0.8 3.4 0.4 1.5 0.8 3.4 0.4 1.9 0.7 3.4 0.4 164 9 164 165 7.5 0.3 8.3 7 11/11/2006 15:10:00 0.7 0.6 3 0.4 0.8 0.7 3 0.4 0.8 0.6 3 0.4 213 45 282 165 7.6 0.1 8 7.3 11/11/2006 15:20:00 2.1 0.4 3 1.1 2.3 0.3 3 1.9 2.4 0.3 3 1.5 271 10 276 165 6.9 0.3 7.5 6.2 11/11/2006 15:30:00 1.6 0.3 2.6 0.7 1.8 0.3 2.6 1.1 1.9 0.3 2.6 1.1 246 9 246 165 6.4 0 6.7 6.2 11/11/2006 15:40:00 1.9 0.7 3 0.4 1.7 0.6 3 0.4 1.9 0.7 3 0.4 310 45 347 165 6.4 0 6.7 6.2 11/11/2006 15:50:00 2.4 0.4 3.4 1.5 2.1 0.6 3 0.7 2.3 0.4 3.4 1.5 1 17 23 165 6.2 0 7 6 11/11/2006 16:00:00 2.1 0.3 3 1.5 1.9 0.5 3 0.7 2.3 0.4 3.4 1.5 27 14 34 165 5.6 0 6 5.2 11/11/2006 16:10:00 2 0.3 3 1.5 1.9 0.3 2.6 1.1 2.2 0.3 3 1.5 29 8 25 165 5.2 0.4 5.7 4.5 11/11/2006 16:20:00 1.9 0.3 2.6 1.1 1.6 0.4 2.6 0.7 2.2 0.3 3.4 1.5 1 15 335 165 4.6 0 4.8 4.5 11/11/2006 16:30:00 3 0.4 4.2 1.9 2.4 0.5 3.4 1.1 3.3 0.4 4.2 2.3 15 9 359 165 4 0.3 4.8 3.5 11/11/2006 16:40:00 4.2 0.4 5.3 3 3.1 0.7 4.6 1.9 4.5 0.5 5.3 3 9 8 11 165 3 0.3 3.5 2.6 11/11/2006 16:50:00 5.8 0.6 7.2 4.2 4.8 1.2 7.2 2.3 5.9 0.6 7.2 4.2 351 8 352 165 2.2 0.2 2.8 1.6 11/11/2006 17:00:00 6.2 0.7 8 4.9 5.8 1.1 8 2.6 6.3 0.8 8.4 4.6 346 5 343 165 1.7 0 1.8 1.4 11/11/2006 17:10:00 6 0.6 7.6 4.9 5.7 1 7.6 2.6 6.4 0.6 8 4.9 348 4 348 165 1.5 0 1.8 0.9 11/11/2006 17:20:00 5.1 0.5 7.2 3.4 5 0.8 7.2 2.6 5.4 0.4 7.2 4.2 341 10 346 165 1.5 0.1 1.8 1.4 11/11/2006 17:30:00 5.4 0.6 7.2 4.2 5.5 0.6 7.2 4.6 5.6 0.6 7.2 4.6 331 6 328 165 1.5 0.2 1.8 1.4 11/11/2006 17:40:00 6 0.5 7.2 4.6 6.2 0.5 7.6 4.9 6.1 0.5 7.6 4.6 337 6 338 165 1.3 0 1.6 1.1 11/11/2006 17:50:00 5.3 0.5 6.8 4.2 4.6 1 7.2 2.6 5.6 0.6 6.8 3.8 354 6 347 165 1.2 0 1.6 0.9 11/11/2006 18:00:00 4.6 0.8 6.8 3 4.7 0.8 6.8 3 4.4 0.7 6.5 2.6 318 21 305 165 1.4 0.1 1.8 0.9 11/11/2006 18:10:00 5 0.9 6.8 2.6 5.1 0.9 7.2 2.6 4.8 0.8 6.5 2.3 311 9 317 165 1.4 0 1.8 1.4 11/11/2006 18:20:00 4.3 0.5 5.7 2.3 4.4 0.5 6.1 2.6 3.9 0.6 6.1 2.3 302 9 290 165 1.5 0 1.8 1.4 11/11/2006 18:30:00 4.7 0.5 6.1 3.4 4.9 0.5 6.1 3.8 3.9 0.5 5.3 2.6 299 5 298 165 1.6 0 1.8 1.6 11/11/2006 18:40:00 4.9 0.4 5.7 3.4 5.1 0.4 6.1 3.8 4.4 0.7 6.1 3 293 5 301 165 1.5 0 2.3 1.4 11/11/2006 18:50:00 4.3 0.6 5.7 3 4.4 0.6 6.1 3 4.2 0.7 6.1 2.6 299 13 288 165 1.4 0.1 2.1 0.9 11/11/2006 19:00:00 3 0.4 4.2 2.3 3.1 0.4 4.2 2.3 3.3 0.4 4.2 2.6 323 4 321 165 1.2 0 1.4 0.9 11/11/2006 19:10:00 3.4 0.4 4.6 2.3 3.5 0.4 4.6 1.9 3.6 0.3 4.6 2.6 328 15 341 165 1.1 0.1 1.4 0.7 11/11/2006 19:20:00 3.5 0.8 5.3 1.5 2.7 0.8 4.9 1.1 3.9 0.7 5.3 2.6 355 8 354 165 0.6 0.2 1.1 -0.1 11/11/2006 19:30:00 3.7 0.8 6.1 1.9 3.1 1.1 6.1 1.1 4.2 0.8 6.5 2.6 355 10 337 165 0.8 0.2 1.4 0.2 11/11/2006 19:40:00 4.3 0.9 6.5 2.6 3.3 1.2 6.1 1.1 4.5 0.8 6.8 2.6 359 9 350 165 0.4 0.2 0.9 -0.3 11/11/2006 19:50:00 2.7 0.9 4.9 0.7 2.5 0.8 4.6 1.1 3 0.8 4.9 1.5 332 19 8 165 0.2 0 0.4 -0.3 11/11/2006 20:00:00 4.7 0.6 6.5 3 4.8 0.6 6.8 3 4.2 0.8 6.1 2.3 301 10 312 165 0.4 0 0.9 -0.1 11/11/2006 20:10:00 5.4 0.8 7.6 3.4 5.5 0.8 7.6 3 5 0.6 6.5 3 303 10 291 165 0.3 0.1 0.9 0.2 11/11/2006 20:20:00 4.6 0.7 6.8 3 4.7 0.7 6.8 3 4.1 0.8 6.5 2.3 304 10 305 165 0.2 0.1 0.7 -0.3 11/11/2006 20:30:00 4.2 0.8 6.5 1.5 4.3 0.8 6.5 1.5 4.1 0.8 6.8 2.3 305 15 281 165 0.2 0.1 0.7 -0.3 11/11/2006 20:40:00 2.4 0.7 4.2 0.4 2.6 0.6 4.6 0.7 2.9 0.6 4.6 1.5 330 11 327 165 0.1 0 0.4 -0.5 11/11/2006 20:50:00 2.4 1 4.6 0.4 2.6 0.9 4.6 0.4 2.6 0.7 4.6 1.1 301 19 289 165 0 0.2 0.4 -0.5 11/11/2006 21:00:00 3.7 0.8 5.3 1.5 3.8 0.7 5.3 1.9 3.4 0.6 5.3 1.9 302 12 302 165 -0.2 0.2 0.2 -0.5 11/11/2006 21:10:00 4 1.3 6.8 0.7 4.2 1.2 6.8 0.7 4.3 1.2 7.2 1.9 294 18 288 165 -0.5 0 -0.1 -0.8 11/11/2006 21:20:00 3.6 0.8 5.3 1.1 3.7 0.8 5.3 1.5 3.5 0.6 4.9 1.5 309 13 290 165 -0.3 0.1 -0.1 -0.8 11/11/2006 21:30:00 4 0.5 5.3 2.3 4.1 0.5 5.3 2.3 3.5 0.5 5.3 1.5 304 7 303 165 -0.2 0.1 -0.1 -0.5 11/11/2006 21:40:00 1.6 1 3.8 0.4 1.9 1 3.8 0.4 1.8 0.6 3.4 0.7 303 12 295 165 -0.5 0.2 -0.1 -1.2 11/11/2006 21:50:00 0.4 0 0.7 0.4 0.4 0.1 1.1 0.4 0.6 0.3 1.5 0.4 140 102 315 165 -0.4 0.2 -0.1 -1.2 11/11/2006 22:00:00 0.6 0.4 1.5 0.4 0.8 0.5 1.9 0.4 1.3 0.6 2.3 0.4 340 72 318 165 -0.3 0 -0.1 -0.8 11/11/2006 22:10:00 2.6 1 4.6 0.7 2.8 0.9 4.6 1.5 2.6 0.7 4.6 1.5 302 9 296 165 -0.7 0.2 -0.1 -1.4 11/11/2006 22:20:00 3.8 0.5 4.9 2.6 3.9 0.5 5.3 2.6 4 0.4 5.3 2.6 314 8 304 165 -1.2 0.3 -0.8 -1.9 11/11/2006 22:30:00 3 0.4 4.2 1.9 3 0.4 4.2 2.3 3.1 0.3 4.2 2.3 314 9 300 165 -1.4 0.1 -1.2 -1.9 11/11/2006 22:40:00 2.9 0.6 4.6 1.9 3.1 0.5 4.6 1.9 3 0.3 4.2 2.3 310 7 302 165 -1.4 0.1 -1.2 -1.9 11/11/2006 22:50:00 3.7 1.5 6.8 1.1 3.9 1.4 6.8 1.5 3.6 1.2 6.5 1.5 304 12 295 165 -1.3 0 -1 -1.7 11/11/2006 23:00:00 4 0.9 6.8 1.1 4.1 0.8 6.8 1.5 3.9 0.8 6.1 1.9 307 9 294 165 -1.2 0 -0.8 -1.7 11/11/2006 23:10:00 3.1 0.7 5.3 1.1 3.2 0.7 5.3 1.5 3.1 0.6 6.1 1.1 308 11 296 165 -1 0.1 -0.8 -1.2 11/11/2006 23:20:00 3.1 1.1 5.7 1.1 3.1 1 5.7 1.5 3.2 1.1 5.7 1.1 327 20 353 165 -0.9 0 -0.5 -1.2 11/11/2006 23:30:00 2.3 0.8 4.6 0.4 2.3 0.7 4.6 0.4 2.8 0.8 5.3 1.5 335 17 346 165 -1.1 0 -0.8 -1.2 11/11/2006 23:40:00 2.5 0.9 3.8 0.4 2.4 0.9 4.6 0.4 2.9 0.7 4.2 1.5 341 11 339 165 -1.2 0 -0.8 -1.4 11/11/2006 23:50:00 3.8 0.8 6.1 1.9 3.7 0.6 5.3 2.3 3.9 0.6 6.1 2.3 338 12 357 165 -1.4 0.1 -0.8 -1.4 11/12/2006 00:00:00 5.1 0.6 6.8 3.4 3.5 0.8 5.3 1.5 5.4 0.7 7.6 3 359 8 358 165 -1.5 0.1 -1.2 -1.9 11/12/2006 00:10:00 3.3 1.6 6.5 0.4 2.9 1.5 6.5 0.4 3.6 1.7 7.2 0.4 349 18 8 165 -0.9 0.2 -0.5 -1.2 11/12/2006 00:20:00 3.1 1.8 6.8 0.4 3.4 2 7.2 0.4 3.6 1.7 7.2 0.7 280 23 285 165 -0.9 0.3 -0.1 -1.4 11/12/2006 00:30:00 4.1 0.9 6.8 2.3 4.5 0.9 6.8 2.3 4.6 0.9 7.2 2.6 281 15 293 165 -1.1 0.1 -0.8 -1.4 11/12/2006 00:40:00 3.6 1.3 6.1 0.4 3.9 1.2 6.5 0.4 4 1.1 6.1 1.5 290 15 299 165 -0.8 0.1 -0.5 -1 11/12/2006 00:50:00 4.6 0.9 6.8 2.6 4.7 0.9 6.8 2.3 4.2 1 6.5 1.5 297 13 307 165 -1 0 -0.5 -1.2 11/12/2006 01:00:00 4.2 0.7 5.7 2.6 4.2 0.7 5.7 2.3 4.1 0.7 5.7 2.3 320 21 333 165 -0.9 0 -0.8 -1 11/12/2006 01:10:00 4.2 0.9 7.2 1.9 4.2 0.8 7.2 1.9 3.9 0.8 7.2 2.3 316 13 311 165 -0.8 0 -0.5 -1.2 11/12/2006 01:20:00 4.8 1 8.4 2.6 4.8 1 8.4 2.6 4.7 0.8 7.2 3 318 12 316 165 -0.8 0 -0.5 -1 11/12/2006 01:30:00 6.1 1 8 3.8 6.1 0.9 8.4 4.2 5.8 1.1 8 3 321 9 316 165 -1.2 0 -0.5 -1.4 11/12/2006 01:40:00 5.9 0.7 7.2 3.8 5.9 0.6 7.6 3.8 5.6 0.8 7.6 3.4 316 11 327 165 -1.3 0 -1 -1.4 11/12/2006 01:50:00 5.5 1.2 8.8 3 5.6 1.2 8.8 3.4 5.2 1.3 8.8 2.6 316 15 327 165 -1 0.1 -0.8 -1.4 11/12/2006 02:00:00 5.6 0.9 9.1 3.4 5.5 1 9.1 3 5.2 1 8.8 3 316 20 341 165 -0.9 0.1 -0.5 -1.2 11/12/2006 02:10:00 6.6 0.8 9.1 4.9 6.7 0.8 9.1 4.9 5.8 0.8 8 3.4 306 8 298 165 -1 0 -0.5 -1.4 11/12/2006 02:20:00 6.7 0.9 9.5 4.2 6.8 0.8 9.1 4.6 6.1 0.9 8 3.8 309 11 292 165 -1.2 0 -1 -1.4 11/12/2006 02:30:00 6.9 1 10.7 3.8 6.9 1 10.3 4.2 6.1 1 9.5 4.2 307 11 301 165 -0.9 0 -0.5 -1.2 11/12/2006 02:40:00 8.3 1 10.3 5.7 8.2 0.9 9.9 5.7 7.4 1.3 11.1 3.8 312 12 310 165 -1.1 0 -0.8 -1.4 11/12/2006 02:50:00 7.7 1.5 12.2 5.3 7.7 1.5 12.2 4.9 7.7 1.4 11.8 5.3 325 12 355 165 -1 0.1 -0.8 -1.2 11/12/2006 03:00:00 6.8 1 9.9 3.4 6.7 1 10.7 3 6.4 1 9.5 3.4 317 17 328 165 -1 0.2 -0.8 -1.4 11/12/2006 03:10:00 8.2 1.8 12.2 4.2 8.2 1.7 12.2 4.2 8 1.7 11.5 3.8 327 13 331 165 -0.8 0.2 -0.3 -1.2 11/12/2006 03:20:00 8.5 1.8 13 4.2 8.5 1.9 13.7 4.9 8.4 1.9 13.3 4.6 326 11 338 165 -0.3 0.1 -0.1 -0.5 11/12/2006 03:30:00 7 2.2 13.3 2.6 6.9 2 12.6 2.3 6.5 2.1 14.5 2.3 324 16 347 165 -0.5 0 -0.1 -0.8 11/12/2006 03:40:00 7 1.7 12.6 3.8 6.9 1.7 13 3.8 6.8 1.5 11.5 3.4 327 17 327 165 -0.4 0 -0.3 -0.8 11/12/2006 03:50:00 6.9 1.2 10.7 4.2 6.8 1.1 10.3 4.6 6.9 1.1 10.3 4.2 324 12 326 165 -0.4 0 -0.1 -0.8 11/12/2006 04:00:00 7 1.5 12.6 4.2 6.9 1.4 12.2 3.8 6.7 1.3 11.8 3.4 319 15 310 165 -0.5 0 -0.1 -0.8 11/12/2006 04:10:00 10.6 2 15.6 6.1 10.4 1.9 15.3 6.1 9.7 1.9 14.5 5.7 327 12 341 165 -0.2 0 -0.1 -0.5 11/12/2006 04:20:00 10.8 1.7 15.6 6.8 10.5 1.9 15.6 6.5 10.1 1.7 15.3 6.8 336 13 335 165 -0.3 0 0.2 -0.3 11/12/2006 04:30:00 12.3 2 17.2 7.2 11.9 2.2 17.6 6.1 11.3 2.2 16.8 5.7 336 10 344 165 -0.2 0 0.2 -0.3 11/12/2006 04:40:00 11.7 2.3 16.8 7.2 11.5 2.3 17.2 6.5 11.1 2.4 15.3 5.3 334 8 322 165 -0.2 0.1 0.2 -0.3 11/12/2006 04:50:00 11.7 1.8 16.1 6.8 11.6 1.8 16.4 7.2 11.3 2 17.6 6.8 334 8 330 165 -0.2 0 0.2 -0.3 11/12/2006 05:00:00 12.7 1.6 16.4 8.8 12.5 1.6 16.1 8.4 12.1 1.7 16.1 8 336 8 325 165 -0.2 0 0.2 -0.3 11/12/2006 05:10:00 13.3 2.2 19.1 7.6 13.2 2.3 19.5 7.6 13.1 2.3 19.1 8 333 8 342 165 -0.2 0.1 0.2 -0.3 11/12/2006 05:20:00 12.7 2.2 17.6 7.6 12.6 2.2 17.9 8 12.4 2.3 17.2 7.2 330 9 335 165 0.2 0 0.4 -0.1 11/12/2006 05:30:00 7.5 1.7 11.8 4.2 7.5 1.7 11.8 4.6 7.5 1.6 11.5 4.2 329 13 338 165 0 0.1 0.7 -0.3 11/12/2006 05:40:00 9.7 1.9 14.5 5.7 9.6 1.9 14.5 5.3 9.4 2 14.5 4.6 329 9 328 165 -0.2 0 -0.1 -0.5 11/12/2006 05:50:00 9.5 1.7 13.7 5.3 9.3 1.7 13.3 5.3 9.2 1.7 14.1 4.6 330 12 335 165 -0.2 0 0.2 -0.5 11/12/2006 06:00:00 8.9 1.8 13 4.9 8.8 1.7 12.6 4.9 8.7 1.5 13 4.2 329 12 325 165 -0.2 0.1 0.2 -0.3 11/12/2006 06:10:00 7.1 1.7 11.5 3.4 7 1.6 11.5 3.4 6.3 1.6 10.7 2.6 325 15 343 165 -0.4 0 0.2 -0.5 11/12/2006 06:20:00 7.4 1.7 13 4.2 7.3 1.7 13 3.8 6.9 1.6 11.1 3.4 325 15 348 165 -0.3 0.1 -0.1 -0.5 11/12/2006 06:30:00 9.3 2 15.3 4.2 9.2 1.9 15.6 4.6 8.3 2 14.5 3.8 325 13 350 165 -0.2 0 -0.1 -0.3 11/12/2006 06:40:00 11.1 1.8 16.8 6.8 11 1.8 16.8 6.8 10.4 1.8 15.6 6.8 333 11 334 165 -0.1 0.1 0.2 -0.3 11/12/2006 06:50:00 10.1 2.3 15.6 5.3 10.1 2.3 16.8 5.3 9.5 2.3 14.9 4.9 331 12 329 165 0.1 0 0.4 -0.3 11/12/2006 07:00:00 8.6 2.2 15.3 4.9 8.6 2.2 14.9 4.9 8.2 2.1 14.9 3.8 332 12 323 165 -0.2 0 0.2 -0.3 11/12/2006 07:10:00 10.1 2.6 15.6 4.9 10.1 2.6 15.6 5.3 9.5 2.6 14.9 4.6 331 13 351 165 -0.1 0.1 0.2 -0.3 11/12/2006 07:20:00 11.5 2.1 16.8 4.9 11.1 2.1 16.4 5.3 11 2.3 17.2 5.7 335 14 334 165 0.2 0 0.2 -0.1 11/12/2006 07:30:00 11.6 1.9 16.4 5.7 11.5 1.9 16.8 6.1 11.1 2 17.2 6.1 331 11 333 165 0.2 0 0.7 -0.1 11/12/2006 07:40:00 10.2 1.9 14.9 5.3 9.9 2 14.9 4.6 10 1.9 15.3 4.9 334 13 316 165 0.1 0 0.7 -0.1 11/12/2006 07:50:00 9.3 1.7 14.5 5.3 9.2 1.7 14.1 5.3 8.8 1.7 13.7 4.9 329 13 341 165 0 0 0.7 -0.3 11/12/2006 08:00:00 10.2 2.3 16.8 3.8 10.1 2.3 17.2 3.8 9.8 2.4 16.4 4.2 330 13 341 165 0.1 0 0.4 -0.1 11/12/2006 08:10:00 10 1.9 14.5 4.9 9.9 1.9 14.1 4.6 9.2 2.2 13.3 3.4 331 16 336 165 0.1 0 0.4 -0.1 11/12/2006 08:20:00 9.6 2.2 15.3 5.3 9.4 2.3 15.3 4.6 8.9 2.1 15.6 4.2 334 15 341 165 0.1 0 0.4 -0.1 11/12/2006 08:30:00 11.2 1.8 16.4 6.1 11 1.9 16.8 5.3 10.5 1.8 14.5 5.7 333 11 339 165 0.1 0 0.2 -0.1 11/12/2006 08:40:00 10.6 2.4 16.8 4.2 10.5 2.5 16.8 4.2 9.8 2.4 16.1 4.9 331 12 333 165 0.1 0 0.4 -0.1 11/12/2006 08:50:00 10.5 2 15.3 5.3 10.5 2 15.6 5.7 9.7 2.1 15.3 4.6 332 13 322 165 0.2 0.1 0.7 -0.1 11/12/2006 09:00:00 8.2 1.7 12.2 4.2 7.8 1.7 12.6 3.8 7.7 1.7 11.1 2.6 339 13 348 165 0.5 0 0.9 0.2 11/12/2006 09:10:00 8.8 2.5 15.3 3.8 8.6 2.6 15.6 3.8 8.4 2.8 16.4 3 334 14 334 165 1.1 0.1 1.6 0.9 11/12/2006 09:20:00 8.1 2.2 13.3 4.2 8 2.1 13.7 4.6 7.6 2.5 12.6 2.6 323 18 334 165 1.4 0.1 1.8 1.4 11/12/2006 09:30:00 6.2 1 9.1 3.8 6.2 1 9.1 3.4 5.5 1.1 9.5 3.4 315 17 321 165 1.1 0 1.6 0.9 11/12/2006 09:40:00 8.2 2.1 13.3 3.4 8.2 2.1 13.7 3.8 7.7 2 13.3 3.8 328 13 328 165 1.5 0.3 2.1 0.9 11/12/2006 09:50:00 8 1.8 13 3.8 7.8 1.7 13 3.8 7.6 1.8 12.6 3.4 324 15 324 165 1.9 0 2.3 1.6 11/12/2006 10:00:00 6.4 1.5 10.3 3.8 6.4 1.4 10.7 3.4 5.8 1.3 9.5 2.6 316 17 300 165 1.9 0.1 2.3 1.6 11/12/2006 10:10:00 7.1 2.2 13.3 2.3 7 2.2 12.6 2.3 6.6 2.3 13.3 1.1 319 22 342 165 1.8 0.1 2.3 1.4 11/12/2006 10:20:00 7.6 1.8 12.6 4.2 7.7 1.7 13.3 4.2 7.1 2 13.3 3.4 314 17 330 165 2 0.2 2.6 1.4 11/12/2006 10:30:00 6.9 1.7 11.8 1.5 6.9 1.6 11.8 1.5 6.1 1.5 10.3 2.3 305 17 343 165 1.7 0.1 2.1 1.1 11/12/2006 10:40:00 8.3 1.7 12.2 3.8 8.3 1.6 11.8 4.2 7.2 1.7 12.2 3.4 293 18 290 165 1.4 0.1 1.8 1.1 11/12/2006 10:50:00 7.7 2.1 13 3.4 7.7 2.1 12.6 2.6 6.7 2.1 11.1 3 295 15 284 165 1.7 0.2 2.1 1.4 11/12/2006 11:00:00 8.6 1.7 11.5 4.2 8.9 1.5 11.5 4.6 8.1 1.7 11.8 3.8 279 10 290 165 1.3 0.1 1.6 0.9 11/12/2006 11:10:00 7.9 1.7 11.8 2.6 8.4 1.5 11.5 3 7.9 1.3 11.5 4.2 276 12 296 165 1.4 0.1 1.8 1.4 11/12/2006 11:20:00 9.5 1.9 13.7 3 9.8 1.8 13.3 3 9.3 1.9 14.5 3 280 11 295 165 1.4 0 1.8 1.4 11/12/2006 11:30:00 7.8 1.7 11.8 3 8 1.7 11.8 3 7.5 1.7 10.7 2.6 283 10 301 165 1.7 0 1.8 1.4 11/12/2006 11:40:00 8.7 1.4 12.2 4.6 8.8 1.5 12.6 4.6 8.1 1.7 12.6 4.2 284 9 274 165 1.8 0.1 2.3 1.6 11/12/2006 11:50:00 9.7 1.4 13 5.7 9.8 1.4 13 6.1 8.9 1.6 12.6 4.2 285 8 293 165 1.7 0.1 2.3 1.4 11/12/2006 12:00:00 8.8 2 12.6 3.4 8.9 1.9 12.6 4.2 8 2 11.8 3 288 9 269 165 1.8 0.2 2.3 1.4 11/12/2006 12:10:00 9.8 2 14.5 4.9 9.8 1.9 14.5 4.6 8.5 2.1 13.7 3 289 10 283 165 2 0 2.6 1.8 11/12/2006 12:20:00 9.3 2.3 14.5 3.4 9.3 2.2 14.1 3.8 8 2.1 14.5 3.4 294 12 294 165 2 0 2.6 1.8 11/12/2006 12:30:00 11 2 15.3 5.3 11 2 15.3 5.7 8.8 1.7 13.7 4.6 296 10 298 165 2.2 0 2.6 1.8 11/12/2006 12:40:00 11.5 1.9 15.6 7.2 11.5 1.9 16.1 6.8 9.6 1.9 16.8 5.3 295 10 297 165 2 0.1 2.3 1.8 11/12/2006 12:50:00 12.6 1.8 16.4 8 12.5 1.7 16.1 7.6 10.1 1.8 16.8 4.6 297 9 288 165 1.8 0.1 2.3 1.4 11/12/2006 13:00:00 13.3 1.3 16.4 9.5 13.2 1.4 16.4 9.9 10.4 1.4 14.5 7.2 301 7 284 165 1.5 0 1.8 1.4 11/12/2006 13:10:00 13.7 1.5 16.8 9.5 13.6 1.5 17.2 9.9 11.1 1.5 15.6 7.2 303 7 306 165 1.5 0 1.8 1.4 11/12/2006 13:20:00 15.5 1.3 18.7 11.8 15.3 1.3 17.9 11.5 12.6 1.4 16.1 8.8 305 7 290 165 1.3 0.2 1.8 0.7 11/12/2006 13:30:00 17.2 1.3 20.2 13 17.1 1.4 20.6 12.6 14 1.8 18.7 10.3 305 8 309 165 1.1 0 1.4 0.7 11/12/2006 13:40:00 17.8 1.3 22.1 13.7 17.6 1.3 21.8 13.3 14.9 1.6 19.9 11.1 306 7 301 165 0.9 0.1 1.4 0.2 11/12/2006 13:50:00 16.9 1.5 21 13.3 16.8 1.6 21 13.3 15.5 1.7 19.5 9.9 310 6 310 165 1.2 0.2 1.6 0.7 11/12/2006 14:00:00 14.3 1.4 19.5 11.1 14.1 1.4 19.5 11.1 13 1.9 17.6 8.8 308 8 312 165 1.6 0 1.8 0.9 11/12/2006 14:10:00 15.2 1.3 18.3 11.5 15 1.3 18.3 11.5 13 1.7 17.6 9.1 306 10 290 165 1.5 0 1.6 1.1 11/12/2006 14:20:00 15.6 1.6 19.5 11.5 15.4 1.7 19.9 11.1 12.7 1.7 18.3 8.8 300 11 286 165 1.4 0.2 1.8 0.7 11/12/2006 14:30:00 15 2.3 21 9.9 14.8 2.3 21 9.5 13.4 1.9 18.7 9.1 308 11 287 165 1.3 0.2 1.6 0.7 11/12/2006 14:40:00 16.7 2.1 21.8 11.1 16.6 2.2 21.8 10.7 15 2.2 21 9.1 306 12 287 165 1.4 0.1 1.6 0.7 11/12/2006 14:50:00 18.2 1.5 22.1 14.5 18.1 1.6 21.8 14.1 15 2.3 20.6 9.5 299 9 310 165 1.2 0 1.4 0.7 11/12/2006 15:00:00 18.3 2.3 24.8 10.3 18.2 2.3 24.8 11.1 15.3 2.5 24.4 9.1 302 9 306 165 0.9 0 1.6 0.7 11/12/2006 15:10:00 19.3 2.7 26 13 19.1 2.7 25.6 13 17 3.1 25.2 10.3 304 11 304 165 0.7 0.2 1.4 0.2 11/12/2006 15:20:00 20.8 2.4 27.1 15.3 20.7 2.4 26.8 15.3 19 2.7 26.3 11.8 307 8 311 165 0.5 0 0.9 0.2 11/12/2006 15:30:00 18.8 2.7 24.8 12.2 18.7 2.7 24.4 12.2 15.9 2.6 22.9 9.5 298 12 305 165 0.2 0.1 0.9 -0.1 11/12/2006 15:40:00 16.8 1.7 22.1 12.2 16.6 1.7 21 11.8 13.4 2 18.7 9.1 294 9 298 165 0.2 0.1 0.4 -0.3 11/12/2006 15:50:00 15 2.4 20.6 10.3 14.9 2.4 20.6 10.3 12.4 2.2 17.6 7.6 300 10 277 165 0.1 0.1 0.4 -0.5 11/12/2006 16:00:00 15.9 1.3 19.1 13 15.9 1.3 19.5 12.6 12.2 1.5 17.2 8.8 295 9 304 165 -0.1 0 0.7 -0.5 11/12/2006 16:10:00 15.5 1.8 21 11.1 15.3 1.9 20.6 10.7 14 2.1 19.5 9.1 309 8 305 165 -0.2 0 0.2 -0.5 11/12/2006 16:20:00 13.8 1.5 17.6 9.5 13.7 1.5 16.8 8.8 11.5 1.7 16.1 6.8 302 11 300 165 -0.3 0.1 0.2 -1 11/12/2006 16:30:00 13.9 2.3 19.5 8.8 13.7 2.3 18.7 8.8 11.8 2.4 18.3 6.5 302 12 309 165 -0.5 0 -0.3 -0.5 11/12/2006 16:40:00 14.1 2.4 19.9 7.2 14 2.3 19.5 7.2 11.7 2.7 18.3 5.3 306 13 310 165 -0.6 0 -0.1 -0.8 11/12/2006 16:50:00 12.4 2.2 16.1 2.6 12.3 2.2 16.4 2.6 9.5 2.2 14.5 1.9 300 15 304 165 -0.7 0 -0.3 -0.8 11/12/2006 17:00:00 9 4.5 16.8 0.7 8.9 4.5 16.4 0.4 6.8 3.3 14.9 0.4 303 56 282 165 -0.8 0 -0.5 -1 11/12/2006 17:10:00 11.8 3.3 16.8 1.9 11.7 3.2 16.8 2.3 8.7 2.9 14.5 1.1 305 21 302 165 -0.9 0 -0.5 -1 11/12/2006 17:20:00 13.8 1.8 17.6 8 13.6 1.8 17.2 8 10.6 1.7 14.1 6.5 300 9 300 165 -0.9 0 -0.5 -1 11/12/2006 17:30:00 14.1 1.9 20.2 8.8 14 1.9 19.1 7.6 12.1 2 20.2 7.2 309 12 305 165 -0.9 0 -0.5 -1 11/12/2006 17:40:00 16.4 2.1 20.6 9.9 16.2 2.1 20.6 9.5 15.2 2.4 21.4 9.1 315 8 302 165 -0.6 0 -0.3 -0.8 11/12/2006 17:50:00 16.2 1.7 21.4 11.1 15.9 1.7 20.6 11.1 15.7 1.8 21.4 11.1 320 7 316 165 -0.7 0.1 -0.1 -1 11/12/2006 18:00:00 13.8 1.2 16.8 10.7 13.6 1.2 16.4 10.7 13.6 1.3 16.1 10.3 319 5 316 165 -1 0 -0.5 -1.2 11/12/2006 18:10:00 12.5 0.8 14.5 10.7 12.3 0.8 14.5 10.7 12 1.1 14.5 9.1 316 7 313 165 -0.9 0 -0.5 -1.2 11/12/2006 18:20:00 10.8 0.9 14.1 8 10.8 0.9 14.1 8.4 10.3 1.1 13.3 6.8 314 10 311 165 -0.8 0.1 -0.3 -1 11/12/2006 18:30:00 11.2 1 13.3 8.4 11 1 13.3 8.4 10.1 1.1 13 7.2 312 9 312 165 -0.6 0 -0.3 -0.8 11/12/2006 18:40:00 10.3 2 16.4 6.5 10.2 2 16.1 6.8 9.5 1.7 15.6 6.1 316 13 298 165 -0.3 0.1 -0.1 -0.5 11/12/2006 18:50:00 8.8 1.7 14.1 4.9 8.3 1.7 14.1 4.9 8.9 1.7 13.7 5.3 337 13 344 165 -0.2 0 0.2 -0.5 11/12/2006 19:00:00 7.8 1.7 12.2 3.8 7.4 1.5 11.8 3.8 7.5 1.5 11.5 4.2 338 15 333 165 -0.1 0 0.2 -0.3 11/12/2006 19:10:00 6.8 1.6 13.3 3.8 6.9 1.5 13 4.6 6.7 1.7 12.2 3.8 320 10 328 165 -0.2 0.2 0.2 -0.8 11/12/2006 19:20:00 6.9 1 9.9 4.6 7 0.9 9.5 4.9 6.3 0.8 8.4 4.6 312 12 305 165 -0.6 0 -0.3 -0.8 11/12/2006 19:30:00 9.3 1 11.8 5.7 9.2 1.1 11.5 5.3 7.9 1 11.1 4.6 306 9 290 165 -0.6 0.1 -0.3 -0.8 11/12/2006 19:40:00 10.1 1 12.6 7.6 10 1 12.2 7.6 8.1 1 11.5 5.7 303 8 302 165 -0.4 0 -0.1 -0.5 11/12/2006 19:50:00 10.8 0.9 13.7 8.8 10.8 0.9 13.3 8.4 9.7 1.1 12.2 6.8 310 10 301 165 -0.3 0 0.2 -0.5 11/12/2006 20:00:00 9.5 1.5 13 6.5 9.3 1.5 13 6.1 8.9 1.4 12.6 5.7 313 11 306 165 -0.3 0 0.2 -0.5 11/12/2006 20:10:00 8.8 1.5 14.9 5.7 8.6 1.5 15.3 5.7 8.7 1.5 14.9 6.1 331 12 340 165 -0.5 0 -0.1 -0.8 11/12/2006 20:20:00 11.3 1.5 15.6 7.6 10.9 1.7 15.6 6.1 11.1 1.7 17.2 7.2 334 16 333 165 -0.3 0.1 0.2 -0.5 11/12/2006 20:30:00 11.5 1.3 15.3 8.4 10.7 1.8 15.3 5.7 11.4 1.3 14.9 7.6 342 13 335 165 -0.3 0 0.2 -0.3 11/12/2006 20:40:00 9.8 1.7 14.5 5.3 9.6 1.7 14.1 4.9 9.5 1.8 15.3 4.9 328 12 334 165 -0.3 0 -0.1 -0.5 11/12/2006 20:50:00 10.8 1.6 16.8 7.6 10.7 1.7 16.8 6.5 10.4 1.7 15.6 5.7 325 15 294 165 -0.3 0.1 -0.1 -0.5 11/12/2006 21:00:00 12 1.7 18.3 6.8 11.9 1.7 17.9 6.8 10.5 1.5 15.6 7.2 306 15 284 165 -0.2 0 0.2 -0.3 11/12/2006 21:10:00 10.3 2 14.9 5.7 10.2 1.9 14.9 5.7 9.1 1.7 14.1 4.6 309 13 297 165 -0.1 0 0.2 -0.3 11/12/2006 21:20:00 8.4 2.2 13.3 3.4 8.2 2.2 13.7 3.4 7.5 2 13.3 1.1 328 22 341 165 -0.2 0 0.2 -0.3 11/12/2006 21:30:00 10.1 3.2 20.6 3.8 9.4 3.2 21.4 3.8 9 2.9 17.2 2.6 344 15 340 165 0.1 0.1 0.4 -0.1 11/12/2006 21:40:00 8 2 13.7 3.8 8 1.9 13.3 3.8 6.8 1.7 13.3 3.8 308 17 293 165 -0.1 0.2 0.2 -0.5 11/12/2006 21:50:00 11.3 1.5 14.5 8 11.2 1.5 14.1 7.2 9.1 1.7 14.5 6.1 299 10 316 165 -0.6 0.1 -0.1 -0.8 11/12/2006 22:00:00 12.5 1.6 16.4 8.4 12.5 1.5 16.4 8.8 9.7 1.4 13.7 6.5 300 9 297 165 -1 0 -0.5 -1.2 11/12/2006 22:10:00 13.2 1.1 15.6 10.3 13 1.1 15.6 10.3 11 1.3 14.5 7.2 305 8 301 165 -1 0 -0.8 -1.2 11/12/2006 22:20:00 13.2 1.5 16.8 9.5 13 1.4 16.4 9.1 10.6 1.3 14.9 7.2 303 10 292 165 -1 0 -0.5 -1.2 11/12/2006 22:30:00 14.6 1.2 18.3 11.1 14.5 1.2 18.7 11.1 12.8 1.9 16.8 8.4 309 11 295 165 -1 0 -0.5 -1.2 11/12/2006 22:40:00 14.5 1.5 17.9 8.8 14.2 1.5 17.9 9.1 13.5 1.6 17.6 8.8 316 10 316 165 -1.1 0 -0.8 -1.2 11/12/2006 22:50:00 14.2 1.3 17.9 11.1 14 1.3 17.6 11.1 12.8 1.7 17.2 8.4 311 9 300 165 -1.2 0 -0.8 -1.4 11/12/2006 23:00:00 14.6 1.5 18.3 9.9 14.4 1.5 17.9 9.9 13.2 1.6 17.6 9.5 310 8 311 165 -1.4 0 -0.8 -1.4 11/12/2006 23:10:00 12.8 1.7 16.8 8.4 12.6 1.6 16.8 8.4 12.3 1.8 17.9 8 318 9 309 165 -1.6 0 -1.2 -1.7 11/12/2006 23:20:00 12.1 1.5 16.1 6.8 12 1.5 16.4 7.2 11.4 1.6 16.1 6.5 314 10 311 165 -1.6 0 -1.2 -1.9 11/12/2006 23:30:00 12.7 1.4 16.4 8.8 12.6 1.3 15.6 8.4 10.8 1.4 16.4 6.1 306 12 302 165 -1.7 0 -1.4 -1.9 11/12/2006 23:40:00 11.7 1.7 16.4 8 11.5 1.7 16.4 7.6 10.6 1.7 15.6 6.8 310 13 284 165 -1.8 0 -1.4 -1.9 11/12/2006 23:50:00 12.6 1.9 19.5 8.4 12.4 1.8 19.5 8.8 11.7 2 17.2 6.5 314 11 316 165 -1.9 0.1 -1.4 -2.1 11/13/2006 00:00:00 14 1.3 17.2 10.7 13.8 1.3 16.8 10.7 12 1.5 15.6 8.4 308 9 302 165 -2 0 -1.7 -2.1 11/13/2006 00:10:00 12.4 1.4 15.6 8.4 12.3 1.4 15.6 8 11 1.4 14.5 7.6 309 9 301 165 -2.1 0 -1.7 -2.4 11/13/2006 00:20:00 13.3 2 20.6 7.6 13.2 1.9 19.9 7.6 11.3 1.9 18.3 6.8 304 9 314 165 -2 0 -1.9 -2.1 11/13/2006 00:30:00 15 2.1 19.9 9.5 14.9 2.1 19.5 8.8 12.7 1.6 17.2 8.8 306 10 298 165 -2.1 0 -1.9 -2.1 11/13/2006 00:40:00 12.3 2 17.9 8 12.1 2 17.9 8.4 11 1.5 16.1 6.8 310 13 294 165 -2.1 0 -1.7 -2.4 11/13/2006 00:50:00 7.3 2.2 13.3 3.4 7.4 2.1 13 3.8 6.9 1.8 12.6 2.6 310 16 289 165 -2 0.1 -1.4 -2.4 11/13/2006 01:00:00 8.8 4.1 17.2 1.1 8.7 4.1 16.8 0.7 8 3.6 14.9 1.9 318 21 290 165 -1.7 0 -1.2 -1.9 11/13/2006 01:10:00 12.4 1.7 17.9 8.4 12.2 1.8 17.2 8.4 11.5 1.5 16.1 7.2 319 15 304 165 -1.8 0.1 -1.4 -2.1 11/13/2006 01:20:00 11.5 1.5 15.6 7.6 11.4 1.5 14.9 8 10.7 1.7 14.9 7.2 322 16 340 165 -1.8 0.1 -1.4 -2.1 11/13/2006 01:30:00 8.8 1.6 14.5 5.3 8.8 1.6 13.7 4.9 8.2 1.3 12.2 3.8 320 17 325 165 -1.7 0 -1.2 -1.9 11/13/2006 01:40:00 9.2 1.6 13.7 4.9 9.1 1.6 13.7 4.9 8 1.7 13 4.6 312 14 279 165 -1.6 0 -1.2 -1.9 11/13/2006 01:50:00 8.1 1.7 12.2 3.8 8 1.7 12.2 4.6 6.9 1.5 10.3 3 318 19 298 165 -1.8 0 -1.4 -1.9 11/13/2006 02:00:00 10.7 2.9 17.9 5.7 10.6 2.8 17.6 5.7 8.9 2.3 14.9 4.9 303 13 286 165 -1.9 0 -1.4 -2.1 11/13/2006 02:10:00 16 1.4 19.5 12.2 15.9 1.4 19.5 12.2 13.1 1.8 17.9 8.4 305 9 301 165 -2.1 0 -1.4 -2.4 11/13/2006 02:20:00 14.1 1.7 18.7 9.9 13.9 1.7 17.9 9.5 12.1 1.6 16.8 7.6 306 12 298 165 -2.2 0 -1.9 -2.4 11/13/2006 02:30:00 13.3 1.6 17.6 9.5 13.2 1.5 17.2 9.1 11.6 1.5 15.3 7.2 307 10 293 165 -2.2 0 -1.9 -2.4 11/13/2006 02:40:00 12.4 1.3 17.2 8.4 12.2 1.3 16.8 8.8 10.5 1.5 14.9 6.8 304 12 297 165 -2.2 0 -1.9 -2.6 11/13/2006 02:50:00 11.7 1.8 17.9 6.8 11.6 1.8 17.2 7.6 10.2 1.3 14.1 7.6 312 16 298 165 -2.4 0 -1.9 -2.6 11/13/2006 03:00:00 10.9 1.5 15.3 7.2 10.6 1.3 14.9 7.6 10.5 1.4 13.7 7.2 327 15 297 165 -2.4 0 -1.9 -2.6 11/13/2006 03:10:00 11.8 1.7 16.8 8 11.4 1.8 17.2 7.6 11.2 1.7 16.1 7.6 331 17 346 165 -2.2 0 -1.9 -2.4 11/13/2006 03:20:00 14.1 2 19.5 8.8 13.9 2 19.5 9.5 12.4 1.9 17.2 8.4 306 13 302 165 -2.2 0 -1.7 -2.6 11/13/2006 03:30:00 14.2 1.5 17.9 11.1 14 1.5 17.9 10.3 12.8 1.4 17.2 9.5 311 12 301 165 -2.2 0 -1.9 -2.4 11/13/2006 03:40:00 15.4 1.7 19.9 10.7 15.2 1.7 19.5 10.7 14.2 1.5 19.1 9.5 312 13 304 165 -2.2 0 -1.9 -2.6 11/13/2006 03:50:00 14.7 1.3 19.5 11.1 14.5 1.4 19.1 11.1 13.8 1.5 18.7 9.1 323 13 305 165 -2.3 0 -1.9 -2.6 11/13/2006 04:00:00 14.6 1.8 20.2 9.1 14.3 1.7 19.9 9.1 14.1 1.8 19.9 9.1 329 15 351 165 -2.4 0 -1.9 -2.6 11/13/2006 04:10:00 16.9 2 22.1 11.8 16.7 1.9 21.4 11.5 15.6 2 20.6 11.5 313 11 304 165 -2.6 0 -2.1 -2.8 11/13/2006 04:20:00 18.4 2.2 22.9 11.8 18.2 2.2 23.3 12.2 17.8 2.4 22.9 11.5 319 9 318 165 -2.8 0 -2.4 -2.8 11/13/2006 04:30:00 19.5 2 26 13.3 19.2 2 26 13.3 18.8 1.9 24.4 12.2 321 10 300 165 -2.7 0 -2.4 -2.8 11/13/2006 04:40:00 19.2 2.4 26 11.5 19 2.4 26 11.8 18.5 2.4 25.2 11.5 316 11 314 165 -2.9 0.1 -2.6 -3.3 11/13/2006 04:50:00 19 1.8 23.3 14.1 18.8 1.8 23.7 13.3 18.2 1.9 23.7 13 316 12 317 165 -3.2 0 -2.8 -3.3 11/13/2006 05:00:00 17.1 1.7 22.1 13 16.9 1.7 21.8 12.6 16.6 1.9 21.8 11.5 319 10 308 165 -3.2 0 -2.8 -3.5 11/13/2006 05:10:00 17 2.1 24.8 13 16.8 2.1 24.8 12.6 16.5 2.1 22.1 12.2 320 9 303 165 -3.4 0 -2.8 -3.5 11/13/2006 05:20:00 19.1 1.7 23.3 13.7 18.9 1.7 23.3 13.3 18.5 1.9 23.7 12.2 318 8 310 165 -3.4 0 -3 -3.5 11/13/2006 05:30:00 19.8 1.5 23.3 16.1 19.6 1.5 23.3 16.1 19.3 1.5 24 14.5 316 8 304 165 -3.6 0 -3.3 -3.7 11/13/2006 05:40:00 18.4 1.8 24.4 13.7 18.2 1.8 24.4 13.7 17.9 1.8 22.1 13 325 12 318 165 -3.4 0 -3.3 -3.5 11/13/2006 05:50:00 19.2 1.7 22.9 13.7 18.9 1.8 22.9 13.3 18.8 1.7 22.9 14.1 323 11 315 165 -3.1 0.2 -2.8 -3.5 11/13/2006 06:00:00 17 1.5 21 13.7 16.7 1.5 20.6 13.3 16.2 1.8 21.4 11.5 318 11 317 165 -2.8 0 -2.6 -3 11/13/2006 06:10:00 17.1 1.6 22.1 13.3 16.8 1.6 22.1 13 16.7 1.7 21.4 11.8 323 8 316 165 -2.6 0 -2.6 -2.8 11/13/2006 06:20:00 17.9 1.6 23.3 12.2 17.6 1.5 22.6 12.6 17.3 1.7 24 12.2 323 9 327 165 -2.6 0 -2.6 -2.8 11/13/2006 06:30:00 17.8 2.2 23.3 12.2 17.6 2.2 23.3 12.2 17.3 2.4 23.3 11.1 317 10 312 165 -2.6 0 -2.6 -2.8 11/13/2006 06:40:00 17.6 1.9 24 12.2 17.3 1.9 23.3 12.6 16.9 2 22.6 11.8 320 9 338 165 -2.6 0 -2.4 -2.8 11/13/2006 06:50:00 17.8 1.7 22.1 13.3 17.6 1.7 21.8 13.3 17 2 22.6 11.1 315 10 314 165 -2.5 0 -2.4 -2.8 11/13/2006 07:00:00 17.2 1.6 23.3 13 17 1.6 22.9 12.6 16.4 1.9 23.7 11.5 314 9 319 165 -2.4 0 -2.1 -2.6 11/13/2006 07:10:00 16.4 1.6 20.6 11.5 16.2 1.6 20.2 11.1 15.7 1.9 21.8 11.1 317 9 316 165 -2.4 0 -2.1 -2.6 11/13/2006 07:20:00 16.4 1.6 20.2 11.5 16.2 1.6 20.2 11.1 15.4 1.9 20.2 10.7 314 8 321 165 -2.3 0 -1.9 -2.6 11/13/2006 07:30:00 14.6 1.9 21.4 10.3 14.5 1.9 21 9.9 13.7 1.9 21 8.8 312 12 316 165 -2.4 0 -1.9 -2.6 11/13/2006 07:40:00 18 2.3 26.3 12.6 17.8 2.3 25.6 13 17.1 2.2 22.1 11.5 312 11 286 165 -2.4 0 -1.9 -2.6 11/13/2006 07:50:00 18.8 1.3 22.1 15.3 18.6 1.3 22.1 14.5 18.4 1.3 21.8 13 318 8 323 165 -2.4 0 -1.9 -2.6 11/13/2006 08:00:00 19.9 1.7 26.3 15.6 19.7 1.7 26.3 15.3 19.7 2 26 13.7 319 10 297 165 -2.4 0 -1.9 -2.6 11/13/2006 08:10:00 20.1 1.8 25.6 15.6 19.8 1.9 25.2 15.3 19.7 1.9 24.8 14.1 318 9 288 165 -2.4 0 -1.9 -2.6 11/13/2006 08:20:00 19.4 1.9 24.8 14.9 19.2 2 24 14.1 18.6 2 24.4 13 313 12 292 165 -2.5 0 -2.1 -2.6 11/13/2006 08:30:00 20.4 2 24.4 13.3 20.1 2 24.4 13.3 19.3 2.1 24 12.6 314 11 310 165 -2.5 0 -2.1 -2.6 11/13/2006 08:40:00 19.5 2.5 24.8 11.1 19.2 2.4 24.4 11.1 18.9 2.5 24.4 11.1 317 9 312 165 -2.5 0 -2.1 -2.6 11/13/2006 08:50:00 18.2 1.8 24 12.6 17.9 1.8 24 12.6 17.8 1.9 22.9 11.8 319 10 323 165 -2.5 0 -2.1 -2.6 11/13/2006 09:00:00 16.6 1.7 21.4 10.7 16.4 1.7 21 10.3 16.2 1.8 21.4 11.5 316 12 313 165 -2.5 0 -2.1 -2.6 11/13/2006 09:10:00 16 2.3 22.1 10.7 15.8 2.3 22.1 10.7 15.3 2.2 21 9.9 316 11 321 165 -2.5 0 -2.1 -2.6 11/13/2006 09:20:00 15.9 2.6 22.6 9.9 15.6 2.5 22.6 9.9 15.1 2.4 21 8.4 316 12 313 165 -2.5 0 -2.1 -2.6 11/13/2006 09:30:00 17.3 2.3 22.9 11.5 17 2.2 22.6 11.5 16.5 2.3 22.6 11.1 317 11 319 165 -2.5 0 -2.1 -2.6 11/13/2006 09:40:00 16.6 2.4 22.6 11.5 16.3 2.4 22.1 11.1 15.7 2.5 23.7 11.1 319 11 321 165 -2.5 0 -2.4 -2.6 11/13/2006 09:50:00 16.7 1.9 21 11.5 16.4 1.9 20.6 11.5 16 2.1 20.6 11.1 318 9 310 165 -2.5 0 -2.1 -2.6 11/13/2006 10:00:00 16.4 2.3 22.6 11.8 16.2 2.3 22.1 11.1 15.8 2.5 21.8 10.3 321 12 318 165 -2.5 0 -2.1 -2.6 11/13/2006 10:10:00 15.7 2.4 22.1 10.3 15.6 2.5 22.1 10.3 15.2 2.6 23.3 7.2 322 13 303 165 -2.1 0.2 -1.9 -2.6 11/13/2006 10:20:00 14.3 2 19.5 9.5 14 2 18.7 9.1 13.4 2 20.2 7.6 321 17 358 165 -1.8 0 -1.4 -1.9 11/13/2006 10:30:00 11.4 1.8 16.4 5.7 11.2 1.9 16.4 4.9 10.6 1.6 16.1 6.1 315 17 309 165 -1.6 0 -1.2 -1.9 11/13/2006 10:40:00 10.7 1.3 14.5 7.6 10.6 1.3 14.1 7.2 9.9 1.2 14.9 6.8 320 17 338 165 -1.8 0.1 -1.4 -1.9 11/13/2006 10:50:00 10.6 1.3 13.3 5.7 10.4 1.3 13.3 5.3 10 1.5 13.7 4.9 321 15 321 165 -1.7 0 -1.2 -1.9 11/13/2006 11:00:00 11.4 2.4 16.8 6.1 11.3 2.3 16.4 5.7 10.3 1.9 15.3 6.8 311 13 292 165 -1.6 0.1 -1.2 -1.9 11/13/2006 11:10:00 12.2 1.9 18.7 6.5 12.1 1.9 18.7 6.8 10.9 1.7 16.4 6.8 307 14 292 165 -1.8 0 -1.4 -1.9 11/13/2006 11:20:00 16.3 2.5 23.7 10.3 16.2 2.6 23.3 9.5 16 2.7 22.9 8.8 333 13 329 165 -2.1 0.3 -1.2 -2.8 11/13/2006 11:30:00 17.9 1.9 22.6 12.2 17.8 2.2 22.9 12.2 17.8 2.1 22.9 11.8 341 9 336 165 -3.4 0.3 -2.6 -3.9 11/13/2006 11:40:00 19.5 1.7 23.3 14.9 19.2 2.3 24.4 13.7 19 2.2 24 13.7 344 7 343 165 -3.8 0.2 -3.3 -4.2 11/13/2006 11:50:00 17.9 2.1 22.9 11.5 16.9 2.5 21.8 10.7 17.8 2.2 23.3 9.5 345 9 354 165 -3.3 0 -3 -3.5 11/13/2006 12:00:00 18.9 2.8 24.4 11.8 18.3 3.2 24.8 9.9 18.6 2.7 26 12.2 342 11 333 165 -3 0.3 -2.6 -3.5 11/13/2006 12:10:00 19.4 2.3 25.6 13 18.5 3.1 25.2 10.7 19 2.6 26.8 10.7 345 9 4 165 -2.6 0 -2.4 -2.8 11/13/2006 12:20:00 15.5 1.8 20.6 10.3 14.8 1.9 19.5 8 14.6 2 20.6 8 327 21 354 165 -2.6 0 -2.1 -2.8 11/13/2006 12:30:00 12.2 2.1 18.3 8 12 2.1 18.3 8 11.5 1.8 17.9 7.6 323 15 316 165 -2.5 0.2 -2.1 -2.8 11/13/2006 12:40:00 13.4 2.4 19.1 7.6 13.1 2.6 19.1 7.2 12.9 2.5 18.7 7.6 336 11 328 165 -2.1 0 -1.9 -2.4 11/13/2006 12:50:00 12.5 2.1 18.7 6.1 11.8 2.2 19.1 5.7 12.3 2.1 17.6 6.5 342 16 318 165 -2.5 0.3 -1.9 -3 11/13/2006 13:00:00 15.6 3.3 27.1 8.8 14.9 3.8 26.3 5.3 14.8 3.5 27.1 6.8 334 17 345 165 -3.4 0.2 -2.6 -3.5 11/13/2006 13:10:00 18.2 3.6 29.8 7.2 17.9 3.8 29.8 7.2 17.6 3.8 27.1 7.2 331 17 331 165 -3.7 0 -3.5 -3.9 11/13/2006 13:20:00 19.6 3.2 28.3 10.3 19.2 3.6 27.5 7.2 19 3.2 27.9 11.1 337 12 333 165 -3.9 0 -3.5 -3.9 11/13/2006 13:30:00 21.7 3.1 28.7 10.7 21.4 3.3 30.6 10.7 21.3 3.3 29.4 10.3 337 12 333 165 -4.1 0.1 -3.5 -4.4 11/13/2006 13:40:00 23.8 2.7 32.1 16.4 23.2 3.1 32.9 14.5 23.3 2.9 33.2 15.3 340 10 334 165 -4.3 0 -4.2 -4.6 11/13/2006 13:50:00 22.8 2.6 31.3 14.9 22.3 3.2 30.9 11.8 22.3 2.7 30.9 16.4 342 8 342 165 -4.4 0 -3.9 -4.6 11/13/2006 14:00:00 21.4 3.2 28.7 11.5 20.8 3.5 30.9 11.5 21.2 3.3 29.1 11.8 336 12 343 165 -4.5 0 -4.2 -4.6 11/13/2006 14:10:00 18.3 4 30.9 8 18.1 4.3 30.2 7.2 17.6 4 30.2 7.2 329 16 327 165 -4.8 0 -4.4 -5 11/13/2006 14:20:00 12.3 3.3 21.8 4.2 11.3 3.6 20.2 3.4 12 3.1 19.9 4.9 348 20 326 165 -5.2 0.2 -4.6 -5.7 11/13/2006 14:30:00 16.1 3.6 24.8 7.2 14.3 3.8 22.6 5.3 15.9 3.8 24.4 5.7 9 14 3 165 -6.1 0.3 -5.3 -6.6 11/13/2006 14:40:00 13.6 2.4 21.8 7.2 11.7 2.6 21.8 6.1 13.5 2.6 22.1 6.8 359 17 20 165 -6.4 0 -6.1 -6.6 11/13/2006 14:50:00 12.9 2.4 19.5 8.4 12.2 2.8 19.1 5.7 12.6 2.4 18.7 7.6 342 13 341 165 -6.2 0 -6.1 -6.6 11/13/2006 15:00:00 9.4 1.5 14.1 4.9 8.6 1.5 13 4.6 9.3 1.4 14.5 6.1 349 18 360 165 -6.2 0.1 -5.7 -6.4 11/13/2006 15:10:00 10 2 15.6 4.9 8.3 1.8 13.7 4.2 9.7 1.9 14.5 4.9 1 17 6 165 -6.2 0 -5.9 -6.4 11/13/2006 15:20:00 7.1 2.3 14.9 3 6.3 2.3 14.1 2.6 6.9 2.4 14.5 3.4 356 18 15 165 -6.1 0 -5.9 -6.4 11/13/2006 15:30:00 13 3.1 25.2 6.1 12.7 3.2 26 5.7 12.6 2.9 24.8 5.7 335 15 338 165 -5.9 0 -5.7 -6.1 11/13/2006 15:40:00 13.9 2.8 21.4 8 13.2 3.1 21 6.1 13.6 2.9 21 7.2 334 18 356 165 -5.8 0 -5.5 -5.9 11/13/2006 15:50:00 16.1 3.8 24.4 8.8 15.3 4 24.4 6.1 15.7 4.1 25.6 8 337 15 334 165 -5.8 0.1 -5.3 -6.1 11/13/2006 16:00:00 21.5 3.2 27.9 11.1 21 3.5 27.1 9.9 21.3 3.6 30.2 10.3 337 13 348 165 -6 0 -5.5 -6.1 11/13/2006 16:10:00 17.3 3.2 27.9 9.5 16.9 3.3 28.3 8 17 3.5 28.3 10.7 337 11 342 165 -5.9 0 -5.7 -6.1 11/13/2006 16:20:00 14.3 3.2 22.6 6.1 13.5 3.2 21.4 5.3 13.8 3.2 22.1 5.7 337 18 344 165 -5.9 0 -5.5 -5.9 11/13/2006 16:30:00 14 3.5 22.1 6.5 13.7 3.6 21.8 5.7 13.8 3.6 22.1 5.3 330 17 330 165 -5.9 0 -5.5 -5.9 11/13/2006 16:40:00 13.6 3.8 21.8 6.1 12.9 4 22.1 4.6 13.6 3.8 21.8 4.6 336 22 334 165 -5.8 0 -5.7 -6.1 11/13/2006 16:50:00 15.9 3.3 24.4 8.8 15.4 3.2 22.6 8.4 15.7 3.6 25.2 8.8 330 16 343 165 -5.8 0 -5.5 -5.7 11/13/2006 17:00:00 16.8 3.2 24.8 6.8 16.5 3.3 23.7 5.3 16.4 3.3 24.4 6.8 334 16 354 165 -5.8 0 -5.5 -5.9 11/13/2006 17:10:00 12.5 3.3 21.4 6.5 12.2 3.3 21.4 6.5 12 3.3 21.8 6.1 332 17 340 165 -5.9 0 -5.5 -6.1 11/13/2006 17:20:00 16 3.8 27.9 6.8 15.3 3.8 26 6.5 15.8 4 26.8 7.6 339 13 343 165 -6 0 -5.7 -6.1 11/13/2006 17:30:00 16.6 3.8 27.9 8.4 16.2 4 28.7 8.4 16.3 4.1 26.8 6.8 331 19 339 165 -6.1 0 -5.7 -6.4 11/13/2006 17:40:00 15.5 3.3 22.9 6.5 14.7 3.1 23.3 6.8 15.4 3.6 23.7 6.8 337 15 347 165 -6.1 0 -5.7 -6.4 11/13/2006 17:50:00 13.8 3.1 22.6 7.2 13.3 3.2 23.3 6.5 13.4 3.2 22.6 6.5 334 17 340 165 -6.1 0 -5.7 -6.4 11/13/2006 18:00:00 16.2 2.6 24.4 9.9 15.5 2.5 24 8.8 15.8 2.9 24 8.8 337 13 352 165 -6.1 0 -5.7 -6.4 11/13/2006 18:10:00 18.8 3.3 28.7 11.1 17.7 3.5 27.9 8.8 18.4 3.3 29.4 11.1 342 13 355 165 -6.1 0 -5.7 -6.4 11/13/2006 18:20:00 17 2.6 24.8 11.8 15.7 2.7 25.2 9.1 16.4 2.6 23.3 10.3 344 11 346 165 -6 0 -5.7 -6.1 11/13/2006 18:30:00 16 2.4 22.9 9.9 15.2 2.6 22.1 9.9 15.7 2.6 24 9.1 338 13 1 165 -6.1 0 -5.7 -6.1 11/13/2006 18:40:00 16.5 2.7 24 9.5 15.3 2.8 23.7 8.8 16.1 2.8 22.9 8.4 341 17 354 165 -6 0 -5.7 -6.4 11/13/2006 18:50:00 14.7 2.3 21 9.1 13.6 2.1 18.7 9.5 14.1 2 20.2 8.8 342 14 355 165 -6.1 0 -5.7 -6.4 11/13/2006 19:00:00 13.9 2.5 22.9 9.1 13.7 2.5 23.3 9.1 13.6 2.4 21.8 8.4 334 13 345 165 -6.2 0 -5.9 -6.4 11/13/2006 19:10:00 14.4 2.2 19.5 9.5 14.2 2.2 19.9 9.5 13.7 2.1 18.7 7.6 320 15 303 165 -6.1 0 -5.7 -6.1 11/13/2006 19:20:00 14.3 1.8 19.1 9.5 14.1 1.8 19.5 9.5 12.9 1.7 18.7 8.8 310 14 301 165 -6.1 0 -5.7 -6.4 11/13/2006 19:30:00 15.9 1.6 20.2 11.8 15.7 1.6 20.2 10.7 14.5 1.8 21 9.9 311 11 320 165 -6.4 0 -6.1 -6.6 11/13/2006 19:40:00 15.6 1.5 20.2 11.5 15.3 1.6 20.2 11.5 14.3 1.8 19.5 9.1 311 11 305 165 -6.5 0 -6.1 -6.6 11/13/2006 19:50:00 15.1 1.3 19.1 11.1 14.9 1.3 18.7 10.7 13.5 1.5 17.2 9.5 309 10 310 165 -6.5 0 -6.1 -6.8 11/13/2006 20:00:00 14.6 1.3 19.1 10.7 14.4 1.3 18.7 11.1 13.4 1.5 17.2 9.5 310 9 300 165 -6.7 0 -6.4 -6.8 11/13/2006 20:10:00 16.1 1.7 20.6 12.2 16 1.7 21.8 11.8 14.1 1.8 19.1 9.5 306 11 308 165 -6.6 0 -6.4 -6.8 11/13/2006 20:20:00 16.4 1.6 20.6 12.2 16.2 1.6 20.6 11.8 15.3 1.7 19.9 10.7 312 12 305 165 -6.8 0.1 -6.6 -7 11/13/2006 20:30:00 16.5 1.1 19.1 13.7 16.3 1.1 18.7 13 15.5 1.2 18.7 11.5 311 9 306 165 -6.9 0 -6.6 -7.2 11/13/2006 20:40:00 17.3 1.6 21.4 13 17.1 1.7 21 13 15.9 2.1 21.4 10.3 308 11 310 165 -7.1 0 -6.8 -7.2 11/13/2006 20:50:00 17.4 2.1 22.6 12.6 17.2 2.2 22.1 12.2 16.3 2.4 21.8 11.8 310 11 312 165 -7.2 0 -6.8 -7.4 11/13/2006 21:00:00 15.6 1.4 21.8 11.5 15.4 1.4 22.1 11.5 14.9 1.5 21 10.7 311 11 312 165 -7.3 0 -7 -7.4 11/13/2006 21:10:00 16.2 1.3 19.1 12.6 16 1.3 19.1 11.8 15.2 1.9 19.9 9.9 314 12 319 165 -7.4 0 -7 -7.6 11/13/2006 21:20:00 19.2 2.6 25.2 11.8 19 2.6 25.2 11.8 18.1 2.5 23.3 12.6 312 11 310 165 -7.5 0 -7 -7.6 11/13/2006 21:30:00 21.3 1.5 25.2 17.6 21.1 1.6 25.2 16.8 20.2 1.6 24.4 15.6 310 7 303 165 -7.7 0 -7.2 -7.9 11/13/2006 21:40:00 21.3 1.7 25.6 17.6 21.1 1.8 25.2 17.2 20.3 1.7 24.4 15.6 312 7 312 165 -7.8 0 -7.4 -8.1 11/13/2006 21:50:00 20.8 1.9 24.8 15.3 20.6 2 24.4 15.6 19.4 1.7 23.7 15.3 311 12 308 165 -7.6 0.1 -7.4 -7.9 11/13/2006 22:00:00 20.9 2.1 25.2 14.1 20.6 2.1 24.8 12.6 19.3 2.3 24.8 13.7 310 9 310 165 -7.5 0 -6.8 -7.6 11/13/2006 22:10:00 21.9 1.7 26 17.2 21.8 1.7 26 17.2 20.3 1.7 24.8 15.3 308 9 309 165 -7.6 0 -7.2 -7.9 11/13/2006 22:20:00 19.2 2.1 24.4 14.5 19 2.1 23.7 13.7 17.7 2.6 23.7 11.1 309 10 305 165 -7.6 0 -7.4 -7.9 11/13/2006 22:30:00 18.9 2.6 27.1 11.8 18.7 2.6 26.8 12.2 17.7 2.5 24.8 11.8 314 9 303 165 -7.6 0 -7.4 -7.9 11/13/2006 22:40:00 21.9 1.9 26.3 16.4 21.7 1.9 26 15.6 20.3 1.8 25.2 14.9 311 10 310 165 -7.6 0 -7.4 -7.6 11/13/2006 22:50:00 20.6 2.5 27.1 13.7 20.4 2.5 26.8 13.7 19.7 2.5 27.9 13.3 313 9 310 165 -7.4 0.1 -7.2 -7.6 11/13/2006 23:00:00 19.4 1.8 24 14.5 19.2 1.8 23.7 14.1 17.2 1.8 21.8 12.6 308 10 289 165 -7.5 0 -7.2 -7.6 11/13/2006 23:10:00 19.6 1.7 24.4 14.9 19.3 1.7 23.7 14.5 17.6 1.9 22.9 12.6 307 10 295 165 -7.5 0 -7.2 -7.6 11/13/2006 23:20:00 18.6 1.9 24.4 13.3 18.4 1.9 24 13 17 2 23.3 11.5 308 9 322 165 -7.5 0 -7.2 -7.6 11/13/2006 23:30:00 16.5 2.2 21.8 10.7 16.3 2.2 21.4 10.7 14.8 2 20.2 10.3 309 12 312 165 -7.5 0 -7.2 -7.6 11/13/2006 23:40:00 16.8 1.7 22.1 11.5 16.6 1.7 22.1 11.5 15.3 1.6 20.2 11.5 307 13 286 165 -7.4 0 -7.2 -7.6 11/13/2006 23:50:00 16.4 1.7 20.6 11.8 16.1 1.7 20.6 12.2 14.7 1.9 21.8 9.9 308 11 308 165 -7.4 0 -7 -7.6 11/14/2006 00:00:00 17.2 2.7 25.2 10.7 17 2.6 25.2 11.1 14.6 2.5 21.4 5.7 303 11 298 165 -7.3 0 -6.8 -7.4 11/14/2006 00:10:00 18.6 2.7 26.3 13.3 18.5 2.7 26 13.3 16.7 2.8 24.4 11.1 307 13 300 165 -7.2 0 -6.8 -7.4 11/14/2006 00:20:00 17.9 2.4 24.8 12.2 17.7 2.4 24.4 12.2 15.7 2.5 21.8 10.3 304 14 298 165 -7.2 0 -6.8 -7.4 11/14/2006 00:30:00 15.7 2.3 22.6 9.1 15.6 2.3 22.1 9.1 14 2.5 22.1 7.6 303 12 294 165 -7.2 0 -6.8 -7.4 11/14/2006 00:40:00 16.8 1.8 21.8 12.2 16.6 1.8 21.8 11.8 14.7 2.3 21 8.4 308 8 305 165 -7.3 0.1 -6.8 -7.4 11/14/2006 00:50:00 16.3 2.3 23.3 10.7 16.1 2.3 23.3 10.3 14.6 2.2 21 9.5 310 12 291 165 -7.3 0 -7 -7.4 11/14/2006 01:00:00 16.3 1.8 22.9 11.8 16.1 1.7 22.6 11.8 14 2.2 20.2 9.5 306 11 299 165 -7.2 0 -6.8 -7.4 11/14/2006 01:10:00 17.8 2.5 24.8 13 17.6 2.5 24.8 12.6 16.6 2.9 24 10.7 311 9 310 165 -7.4 0 -7 -7.6 11/14/2006 01:20:00 20.3 2 25.6 14.1 20 2 25.2 13.7 19.3 2.4 26 14.1 316 8 313 165 -7.5 0 -7.2 -7.6 11/14/2006 01:30:00 19.8 2.1 24.4 13.7 19.6 2.1 24.4 13.3 19.1 2.2 23.3 11.8 315 8 309 165 -7.4 0 -7.2 -7.6 11/14/2006 01:40:00 18.2 2.5 25.2 12.6 18 2.5 24.4 13 17.6 2.6 25.6 12.2 317 8 316 165 -7.4 0 -7 -7.6 11/14/2006 01:50:00 20.2 2.5 27.1 13.7 20 2.5 26.8 13 18.4 2.4 23.7 11.8 310 7 294 165 -7.6 0 -7.2 -7.9 11/14/2006 02:00:00 21.3 1.9 25.2 14.9 21 2 25.2 15.3 19.9 2.3 25.2 14.1 311 8 301 165 -7.9 0 -7.4 -8.1 11/14/2006 02:10:00 22 2.4 27.5 16.8 21.7 2.4 27.9 16.1 21.7 2.6 27.5 15.3 317 8 334 165 -7.8 0 -7.6 -8.1 11/14/2006 02:20:00 23.2 1.8 27.5 18.7 23 1.8 27.1 18.3 23.1 2 27.5 18.3 318 6 313 165 -7.7 0 -7.4 -8.1 11/14/2006 02:30:00 21.7 2.4 27.1 15.6 21.4 2.3 27.1 14.9 21.2 2.5 26.8 13.3 319 7 312 165 -7.6 0.2 -7 -8.1 11/14/2006 02:40:00 24.8 2 30.2 17.6 24.5 2.1 30.6 17.6 24.2 2.2 29.1 17.6 316 7 310 165 -6.9 0.2 -6.6 -7.2 11/14/2006 02:50:00 24.3 2.1 29.1 18.7 24.1 2.2 29.1 18.3 23.7 2.2 29.4 17.6 316 7 309 165 -6.7 0.1 -6.4 -7 11/14/2006 03:00:00 25.6 1.9 29.8 14.9 25.3 1.9 29.8 14.9 25.3 2.3 29.8 16.8 319 5 316 165 -7.1 0 -6.8 -7.4 11/14/2006 03:10:00 25.6 1.8 29.4 20.2 25.3 1.9 29.1 19.9 25 2.2 29.8 18.7 317 5 306 165 -6.9 0 -6.8 -7 11/14/2006 03:20:00 26.1 1.3 29.1 21.8 25.8 1.4 29.4 21 25.9 1.5 30.2 20.2 317 4 323 165 -6.9 0 -6.6 -7.2 11/14/2006 03:30:00 26.2 1.8 29.8 21.4 26 1.9 29.8 21.4 26.3 2.2 31.3 19.5 317 5 319 165 -6.9 0 -6.6 -7 11/14/2006 03:40:00 22 1.8 26.3 16.8 21.8 1.8 25.6 16.1 21.9 2 26.3 16.1 317 5 324 165 -7 0 -6.6 -7.2 11/14/2006 03:50:00 21.7 2 27.1 17.2 21.5 2 27.1 17.6 20.9 2 26.8 16.1 315 7 316 165 -6.8 0 -6.6 -7 11/14/2006 04:00:00 20.6 2 25.6 14.1 20.4 2 26 14.1 19.5 2 25.6 14.5 314 7 317 165 -6.6 0 -6.4 -6.8 11/14/2006 04:10:00 21.3 1.7 25.6 16.8 21.1 1.7 25.6 17.2 20.4 1.9 24.8 14.9 313 7 316 165 -6.5 0 -6.4 -6.6 11/14/2006 04:20:00 20.9 1.7 24.4 15.3 20.7 1.7 24.4 15.3 19.7 1.7 24.4 16.1 313 8 309 165 -6.5 0 -6.1 -6.6 11/14/2006 04:30:00 23.1 1.8 27.9 17.2 22.9 1.8 28.3 16.4 21.7 2.2 27.9 14.9 310 7 306 165 -6.4 0 -6.1 -6.6 11/14/2006 04:40:00 21.5 2.1 27.1 16.4 21.3 2.1 27.1 16.4 20.6 2.2 27.1 16.1 314 8 313 165 -6.5 0 -6.1 -6.8 11/14/2006 04:50:00 23.7 2 29.4 17.9 23.5 2.1 29.1 17.9 23.1 2.3 29.4 16.4 314 6 309 165 -6.5 0 -6.1 -6.6 11/14/2006 05:00:00 23.4 1.5 27.1 19.9 23.2 1.5 26.8 19.5 22.5 1.9 27.5 17.6 312 6 305 165 -6.5 0 -6.1 -6.6 11/14/2006 05:10:00 22 1.6 25.2 17.6 21.8 1.6 25.2 17.2 21.4 1.5 25.2 16.8 314 6 314 165 -6.4 0 -6.1 -6.6 11/14/2006 05:20:00 19.4 1.9 23.3 13.7 19.2 1.9 23.3 13 18.6 2.1 24 13.3 314 9 322 165 -6.4 0 -6.1 -6.6 11/14/2006 05:30:00 18.9 2.1 23.3 13.7 18.8 2.1 23.3 13.3 17.9 2.2 22.6 9.9 313 10 300 165 -6.1 0 -5.9 -6.4 11/14/2006 05:40:00 19.7 1.7 24.4 14.9 19.5 1.7 24 14.9 16.6 2 23.7 12.2 305 8 295 165 -6 0 -5.7 -6.1 11/14/2006 05:50:00 17.7 2.5 24 11.1 17.5 2.5 24 11.1 16.5 2.4 23.3 10.3 313 9 307 165 -5.9 0 -5.7 -6.1 11/14/2006 06:00:00 19.1 1.8 24.8 15.3 18.9 1.9 24.4 14.9 18.1 2 23.7 13 313 8 311 165 -5.9 0.1 -5.7 -6.1 11/14/2006 06:10:00 19.7 2.9 26.8 13.7 19.4 3.1 26.8 13 19 2.8 25.6 12.6 318 9 285 165 -5.8 0 -5.5 -5.9 11/14/2006 06:20:00 22 2.6 27.9 14.9 21.9 2.7 28.3 14.9 20.9 2.5 26.8 14.9 314 9 315 165 -5.7 0 -5.5 -5.7 11/14/2006 06:30:00 23.2 2.4 31.8 18.7 23 2.5 31.8 18.3 22.5 2.4 30.2 16.8 313 8 302 165 -5.6 0 -5.3 -5.7 11/14/2006 06:40:00 23.6 1.7 28.3 17.9 23.6 1.8 28.3 17.6 22.7 2 28.7 15.6 311 7 304 165 -5.6 0 -5.3 -5.7 11/14/2006 06:50:00 20.2 2 25.6 13.3 20 2.1 24.4 13 19.2 2.2 24.4 12.6 313 10 304 165 -5.8 0 -5.5 -5.9 11/14/2006 07:00:00 22.6 2.3 28.3 16.1 22.6 2.3 28.3 16.4 21.2 2.4 27.1 14.1 310 9 304 165 -5.8 0 -5.5 -5.7 11/14/2006 07:10:00 22 2 27.1 15.6 21.8 2 27.1 16.1 20.5 2.3 27.1 12.6 313 10 298 165 -5.7 0 -5.5 -5.9 11/14/2006 07:20:00 20.8 2.4 27.5 13.7 20.5 2.5 27.5 13.3 20.3 2.5 27.9 12.2 320 9 316 165 -5.6 0 -5.3 -5.7 11/14/2006 07:30:00 22.5 2.6 29.4 14.9 22.3 2.7 28.7 14.5 21.8 2.9 29.4 13 319 8 319 165 -5.6 0 -5.3 -5.7 11/14/2006 07:40:00 23.7 2.3 30.2 17.2 23.6 2.4 30.2 17.2 23.2 2.6 30.6 16.8 316 9 300 165 -5.5 0 -5.3 -5.7 11/14/2006 07:50:00 23.7 2.4 29.8 18.3 23.7 2.4 29.4 18.3 22.8 2.4 28.3 16.1 312 6 300 165 -5.8 0.1 -5.3 -5.9 11/14/2006 08:00:00 24.1 1.7 28.7 20.2 24 1.9 29.1 19.9 23.5 2.2 31.3 16.1 313 7 307 165 -5.9 0 -5.5 -5.9 11/14/2006 08:10:00 24.2 1.7 27.9 20.2 24.1 1.8 27.5 19.9 23.3 2 28.7 16.1 312 7 317 165 -5.9 0 -5.7 -6.1 11/14/2006 08:20:00 25.9 2 30.9 20.2 25.9 2.1 30.9 20.6 25.4 2.3 31.8 18.3 313 9 316 165 -5.9 0 -5.5 -5.9 11/14/2006 08:30:00 25.6 1.7 29.8 21.4 25.6 1.8 29.8 21 25.3 1.9 30.2 20.2 313 8 306 165 -5.7 0 -5.5 -5.7 11/14/2006 08:40:00 23.4 1.7 27.5 18.7 23.3 1.7 27.5 18.3 23 2.2 29.4 15.6 315 7 315 165 -5.5 0 -5.3 -5.7 11/14/2006 08:50:00 21.9 2.3 28.7 15.6 21.8 2.3 28.3 15.3 20.4 2.7 27.9 13.3 312 9 319 165 -5.3 0.1 -5 -5.7 11/14/2006 09:00:00 21.4 2 26 16.1 21.3 2 26.3 15.6 20.3 2.3 27.1 15.3 312 8 320 165 -5 0 -4.6 -5.3 11/14/2006 09:10:00 23.3 2.3 29.8 15.3 23.1 2.3 29.8 14.9 22.7 2.7 29.8 14.9 318 9 312 165 -5 0 -4.6 -5.3 11/14/2006 09:20:00 23.4 2.1 28.3 17.2 23.3 2.3 28.3 16.8 23.2 2.4 29.1 16.8 319 7 308 165 -4.8 0 -4.6 -5 11/14/2006 09:30:00 21.4 2.6 27.1 10.7 21.2 2.7 27.1 9.9 21.1 2.8 27.1 13.3 319 11 325 165 -4.7 0 -4.4 -5 11/14/2006 09:40:00 23.4 2.6 29.4 16.4 23.2 2.7 29.8 16.1 22.4 2.7 29.8 14.9 316 11 312 165 -4.3 0.1 -3.9 -4.6 11/14/2006 09:50:00 23.1 2.8 30.2 16.4 23 2.8 30.2 16.4 22.6 2.9 30.2 15.6 316 10 313 165 -4.2 0 -3.9 -4.4 11/14/2006 10:00:00 20.3 2.1 26 14.5 20.1 2.1 25.6 14.9 19.4 2.5 26.3 13.7 316 8 320 165 -3.9 0.2 -3.3 -4.4 11/14/2006 10:10:00 19.7 2.5 25.2 12.2 19.6 2.5 25.2 12.2 17.8 2.5 23.7 11.1 310 11 296 165 -3.4 0 -3.3 -3.5 11/14/2006 10:20:00 20.2 2.4 26 14.9 20.1 2.4 26 14.9 19.2 2.7 26.8 12.2 316 11 302 165 -3.4 0 -3 -3.5 11/14/2006 10:30:00 21.8 2.2 27.5 14.5 21.6 2.2 27.5 14.9 21.3 2.3 28.3 13.7 319 9 315 165 -3.4 0 -3.3 -3.5 11/14/2006 10:40:00 20.5 2.2 26 14.1 20.3 2.2 26 14.9 19.8 2.4 25.6 12.2 320 9 312 165 -3.4 0 -3 -3.5 11/14/2006 10:50:00 19.7 2.2 26.3 13.3 19.4 2.2 25.6 12.6 18.9 2.2 26 13.7 318 10 306 165 -3.2 0 -3 -3.5 11/14/2006 11:00:00 20.7 2.4 26 14.5 20.5 2.4 26 14.9 19.2 2.5 26 12.6 312 9 302 165 -3.1 0 -2.8 -3.3 11/14/2006 11:10:00 22 2.5 29.1 16.1 21.8 2.5 29.1 15.6 20.9 2.5 28.3 14.9 315 10 255 165 -2.9 0 -2.6 -3 11/14/2006 11:20:00 20.6 1.8 26 16.1 20.4 1.9 25.2 15.6 19.7 2.2 25.6 14.5 315 8 313 165 -2.8 0 -2.4 -2.8 11/14/2006 11:30:00 19.7 2 25.6 13.7 19.4 2 24.8 14.5 18.5 2.2 24 11.5 314 10 310 165 -2.6 0 -2.4 -2.8 11/14/2006 11:40:00 17.6 2 22.9 13.3 17.4 2.1 22.6 13 16.9 2.2 21.8 11.1 316 10 304 165 -2.5 0 -2.4 -2.8 11/14/2006 11:50:00 19.6 2.5 26.3 13.3 19.4 2.5 26.3 13.7 18.5 2.5 26.3 13.3 313 9 322 165 -2.4 0 -2.1 -2.6 11/14/2006 12:00:00 20 2 24.4 14.5 19.8 2 24.8 13.3 18.9 2.3 25.2 13 314 9 331 165 -2.2 0 -1.9 -2.4 11/14/2006 12:10:00 20.5 2.4 27.5 14.9 20.3 2.5 27.1 14.9 19.6 2.6 26.3 13.7 314 9 310 165 -2.1 0 -1.7 -2.1 11/14/2006 12:20:00 17.8 2.3 23.7 12.6 17.6 2.3 23.7 11.8 17.3 2.6 23.7 11.5 315 8 314 165 -2 0 -1.7 -2.1 11/14/2006 12:30:00 20.6 2.6 27.1 13.7 20.4 2.6 27.5 14.1 20 2.8 27.5 11.8 318 9 312 165 -2 0 -1.4 -2.1 11/14/2006 12:40:00 21.2 2.4 27.5 14.9 21.1 2.4 27.9 14.5 20.5 2.6 27.9 14.1 314 9 314 165 -2.1 0.1 -1.7 -2.6 11/14/2006 12:50:00 20.2 2.1 25.6 13.7 20.1 2.1 24.8 13.3 19.9 2.5 25.6 11.1 314 7 321 165 -2.2 0 -1.9 -2.4 11/14/2006 13:00:00 19.9 2.1 25.2 15.6 19.6 2.1 24.8 14.9 18.9 2.2 24 12.6 313 8 313 165 -2.2 0.1 -1.9 -2.6 11/14/2006 13:10:00 17.6 2.1 22.9 11.8 17.3 2.1 22.9 11.8 16.4 2.2 23.7 10.7 315 10 289 165 -1.8 0 -1.4 -1.9 11/14/2006 13:20:00 17.4 2.4 26.3 11.5 17.2 2.4 26 12.2 16.5 2.5 26.8 11.1 318 11 317 165 -1.7 0 -1.4 -1.9 11/14/2006 13:30:00 22.5 4 30.9 13.7 22.3 4 30.6 13.7 21.2 3.8 30.6 13.3 314 11 302 165 -1.6 0 -1.2 -1.9 11/14/2006 13:40:00 23.4 2.9 31.3 16.4 23.3 3.1 30.9 16.1 22.9 3.5 31.3 15.3 315 9 291 165 -1.7 0 -1.4 -1.9 11/14/2006 13:50:00 21.4 2.3 26.8 14.9 21.3 2.3 26.8 15.3 20.5 2.5 25.6 13 315 9 327 165 -1.9 0.1 -1.4 -2.1 11/14/2006 14:00:00 22.3 2 26.8 15.3 22.2 2.1 27.1 14.9 20.9 2.4 27.1 13 309 7 305 165 -2 0 -1.7 -2.1 11/14/2006 14:10:00 20.8 2.6 27.1 13.3 20.6 2.6 26.8 13.3 20 2.9 28.3 14.1 316 8 315 165 -1.8 0 -1.4 -1.9 11/14/2006 14:20:00 17.7 2.9 25.2 12.2 17.5 3.1 25.2 11.8 15.8 2.3 22.1 11.5 311 11 302 165 -1.7 0 -1.2 -1.9 11/14/2006 14:30:00 20.4 2.1 27.5 16.1 20.3 2.1 27.5 15.6 18.6 2.9 26.3 12.2 310 8 309 165 -1.9 0 -1.4 -2.1 11/14/2006 14:40:00 20.9 2.6 27.9 15.3 20.7 2.6 28.3 15.6 19.3 2.6 26.3 12.6 311 8 319 165 -1.8 0 -1.4 -1.9 11/14/2006 14:50:00 21.8 2.4 29.1 15.6 21.5 2.4 29.1 15.6 20.3 2.4 26.3 13.3 316 13 307 165 -1.7 0 -1.4 -1.9 11/14/2006 15:00:00 21.4 3.2 27.9 13.7 21.3 3.2 28.3 14.1 21.1 3.3 27.5 12.6 320 13 325 165 -2.2 0.1 -1.4 -2.6 11/14/2006 15:10:00 17.4 2.1 24.4 12.2 16.6 2.4 24 9.5 17.1 2.2 23.7 11.1 336 15 323 165 -3 0.3 -2.1 -3.5 11/14/2006 15:20:00 18.3 2.8 26.8 11.5 18 2.8 26.8 11.5 17.8 2.8 25.6 11.8 332 13 329 165 -3.8 0 -3.3 -4.2 11/14/2006 15:30:00 18.5 2.5 26.3 12.2 18.2 2.7 26.3 11.1 17.3 2.8 26 10.3 323 20 339 165 -4.3 0.1 -3.5 -4.6 11/14/2006 15:40:00 18.4 2.6 24.8 12.6 18.3 2.6 25.2 12.6 17.7 2.7 24.8 11.8 321 13 305 165 -4.5 0 -4.4 -4.6 11/14/2006 15:50:00 21.7 3.1 30.6 14.1 21.6 3.2 31.3 14.5 21.1 3.3 32.1 12.6 315 11 301 165 -4.5 0 -3.9 -4.6 11/14/2006 16:00:00 20.1 2 26.8 14.9 20 2 26.3 14.1 19.9 2.1 26.8 13.3 318 8 296 165 -4.7 0.1 -4.4 -5 11/14/2006 16:10:00 23.1 2.6 31.3 17.9 23 2.6 30.9 17.9 22.6 2.7 32.4 16.4 316 12 315 165 -4.9 0 -4.6 -5 11/14/2006 16:20:00 24 2.5 30.2 16.4 23.9 2.6 30.2 16.8 23.8 2.8 31.3 15.6 319 9 321 165 -4.8 0 -4.4 -5 11/14/2006 16:30:00 23.9 2.7 34.4 19.1 23.8 2.7 34.8 19.1 23.6 2.9 36.3 15.3 321 12 310 165 -4.5 0 -4.4 -4.6 11/14/2006 16:40:00 22.7 2.6 29.8 15.3 22.5 2.6 29.8 15.3 22.5 2.8 29.8 15.6 322 10 333 165 -4.5 0 -4.2 -4.6 11/14/2006 16:50:00 22.6 2.5 28.7 16.4 22.4 2.5 28.3 16.4 21.5 2.4 26.3 15.3 314 12 314 165 -5 0.2 -4.4 -5.5 11/14/2006 17:00:00 23.3 2.2 29.4 17.9 23.1 2.2 28.7 17.6 22.8 2.3 29.1 16.8 319 11 326 165 -5.4 0 -5 -5.7 11/14/2006 17:10:00 25.4 2.9 35.2 17.9 25.2 3.1 35.5 17.6 24.8 3.1 33.6 17.2 315 9 292 165 -5.6 0 -5.3 -5.7 11/14/2006 17:20:00 27.3 2.9 34.8 20.2 27.1 2.9 34 19.1 26.3 3.1 33.6 19.1 311 9 297 165 -5.6 0 -5.5 -5.7 11/14/2006 17:30:00 27 3.2 36.7 18.7 26.7 3.2 36.3 19.5 25.9 3.3 34.4 16.1 312 9 334 165 -5.8 0 -5.5 -5.9 11/14/2006 17:40:00 26 3.1 34.4 18.3 25.8 3.1 34.8 17.9 25.1 3.1 34 17.9 315 11 319 165 -5.9 0 -5.7 -5.9 11/14/2006 17:50:00 26.4 2.8 32.9 16.4 26.2 2.8 32.9 16.4 25.2 2.9 32.1 15.6 313 12 305 165 -5.9 0 -5.5 -6.1 11/14/2006 18:00:00 23.5 3.6 32.9 14.1 23.3 3.8 32.9 13.7 23 3.8 31.8 13 318 11 314 165 -5.9 0 -5.7 -6.1 11/14/2006 18:10:00 22.4 2.7 29.4 16.1 22.2 2.7 29.4 16.1 21 3.2 28.7 13.7 310 8 311 165 -6.1 0 -5.7 -6.4 11/14/2006 18:20:00 24 2.8 33.2 17.9 23.8 2.8 32.4 17.6 22.6 2.9 30.9 15.3 311 9 302 165 -6.4 0.1 -5.9 -6.6 11/14/2006 18:30:00 23.4 3.5 36.3 15.3 23.2 3.5 36.7 15.3 22.5 3.1 33.2 14.1 317 13 290 165 -6.5 0 -6.1 -6.8 11/14/2006 18:40:00 18.9 2.8 25.2 11.8 18.7 2.8 25.2 12.2 18.1 2.9 26 10.7 320 12 295 165 -6.7 0 -6.4 -6.8 11/14/2006 18:50:00 18.6 2.6 25.6 11.8 18.4 2.7 25.2 11.8 18.1 2.6 25.6 11.5 326 14 325 165 -6.8 0.1 -6.6 -7 11/14/2006 19:00:00 19.1 2.3 24.8 11.5 18.9 2.3 25.2 12.2 18 2.4 23.7 12.2 315 13 303 165 -6.9 0 -6.6 -7.2 11/14/2006 19:10:00 15.7 3.1 23.7 8.8 15.6 2.9 24 8 15.1 3.1 24.4 7.2 323 12 289 165 -7.4 0.2 -6.8 -7.9 11/14/2006 19:20:00 16.6 2.1 22.6 11.5 16.5 2.1 23.3 10.3 15.6 2.2 27.9 10.7 317 18 264 165 -7.7 0 -7.4 -8.1 11/14/2006 19:30:00 20.1 2.8 31.8 11.5 19.6 2.8 32.4 10.3 19.2 3.2 30.9 11.5 330 19 345 165 -7.9 0.1 -7.4 -8.1 11/14/2006 19:40:00 21.4 3.3 30.2 12.6 21.2 3.3 31.3 12.6 20 3.6 30.9 11.5 314 15 344 165 -8.2 0 -8.1 -8.5 11/14/2006 19:50:00 17.9 2.5 24.4 11.5 17.7 2.4 24 9.9 16.2 2.4 22.1 9.1 313 15 288 165 -8.5 0.1 -8.1 -8.7 11/14/2006 20:00:00 19 3.1 26.8 12.2 18.9 3.1 27.1 11.8 17.8 3.5 27.1 10.3 312 13 304 165 -8.5 0 -8.3 -8.7 11/14/2006 20:10:00 15.5 2.7 24.8 9.1 15.4 2.7 26 9.1 14.4 2.4 21.4 8.8 317 15 298 165 -8.6 0 -8.3 -8.9 11/14/2006 20:20:00 18.6 2.9 27.5 12.2 18.4 2.9 27.9 12.2 17.3 3.2 27.5 9.9 316 14 325 165 -8.8 0 -8.5 -9.1 11/14/2006 20:30:00 17.8 1.8 24 13.3 17.6 1.8 24.4 13.7 17 1.9 24.4 11.5 318 11 312 165 -9 0 -8.7 -9.1 11/14/2006 20:40:00 21.8 2.4 27.9 15.3 21.7 2.4 27.9 15.6 20.8 2.5 28.3 14.5 313 10 302 165 -9.2 0 -8.7 -9.3 11/14/2006 20:50:00 21.1 2.4 27.1 15.3 20.8 2.4 27.5 14.9 20.4 2.4 28.3 14.1 318 10 311 165 -9.4 0 -9.1 -9.7 11/14/2006 21:00:00 20.3 2.4 25.6 15.3 20.1 2.4 24.8 14.1 18.9 2.1 24 14.1 313 10 298 165 -9.6 0.1 -9.3 -10 11/14/2006 21:10:00 19.5 2.6 27.5 14.1 19.3 2.6 27.5 13.7 18.5 2.6 26.8 13 316 12 300 165 -9.9 0 -9.7 -10.2 11/14/2006 21:20:00 23.2 2 29.8 18.3 22.9 2 29.4 17.6 22.8 2.2 27.9 17.6 324 9 323 165 -10.1 0.1 -9.7 -10.2 11/14/2006 21:30:00 22.7 2.4 29.8 17.9 22.4 2.5 29.1 15.3 22.2 2.6 30.6 16.8 322 12 305 165 -10.2 0 -10.2 -10.4 11/14/2006 21:40:00 21.2 3.5 29.8 13.3 21 3.5 29.4 13 21.1 3.8 29.1 10.3 323 10 319 165 -10.2 0 -10 -10.4 11/14/2006 21:50:00 17.2 2.2 24 10.7 16.7 2.5 23.7 8.4 16.6 2.3 22.6 11.1 325 15 313 165 -10.3 0 -10.2 -10.6 11/14/2006 22:00:00 17.8 2.3 26 13 17.7 2.3 25.2 12.6 16.5 2.2 22.9 10.7 310 13 283 165 -10.3 0 -10.2 -10.6 11/14/2006 22:10:00 20.1 2.2 27.5 14.5 20 2.2 27.1 14.5 18.6 2.7 25.6 11.1 311 11 297 165 -10.5 0 -10.2 -10.8 11/14/2006 22:20:00 21.8 2.5 29.1 16.1 21.5 2.5 28.3 16.1 21.3 2.6 28.3 15.3 320 9 323 165 -10.7 0 -10.6 -11 11/14/2006 22:30:00 22.8 1.7 27.9 17.9 22.6 1.7 27.5 17.9 22.3 1.8 27.1 16.1 316 7 308 165 -10.9 0 -10.6 -11.2 11/14/2006 22:40:00 23.6 1.7 27.5 17.9 23.4 1.7 27.1 17.6 22.9 2 27.5 16.1 313 8 307 165 -11.1 0 -10.8 -11.4 11/14/2006 22:50:00 23.1 2.1 28.3 17.6 22.9 2.2 28.3 17.2 22.1 2.3 27.9 17.2 312 8 314 165 -11.3 0.1 -11 -11.6 11/14/2006 23:00:00 22.5 1.7 26.3 17.2 22.3 1.7 26 17.2 21.6 1.7 26 17.2 314 7 307 165 -11.5 0 -11.4 -11.8 11/14/2006 23:10:00 21.7 1.2 25.6 17.6 21.5 1.2 25.6 17.2 20.5 1.7 24.8 15.6 311 5 312 165 -11.6 0 -11.4 -11.8 11/14/2006 23:20:00 20.1 1.9 23.7 14.1 19.9 1.9 23.7 14.1 18.9 1.9 24 11.8 311 6 312 165 -11.6 0 -11.4 -11.8 11/14/2006 23:30:00 22.3 1.5 26 17.2 22.2 1.5 26 17.6 21 1.7 24.8 13.7 308 5 307 165 -11.8 0.1 -11.6 -12 11/14/2006 23:40:00 23 1.5 26.3 18.3 22.9 1.5 26.3 18.3 20 1.5 24.8 15.3 305 6 301 165 -11.9 0 -11.8 -12 11/14/2006 23:50:00 21.8 1.5 25.6 17.6 21.6 1.5 25.2 17.6 19.9 1.5 23.7 15.3 308 6 314 165 -11.8 0 -11.6 -12 11/15/2006 00:00:00 21.7 1.8 27.1 17.6 21.5 1.8 26.8 17.2 20.8 2 26.8 16.1 312 7 310 165 -11.7 0 -11.4 -11.8 11/15/2006 00:10:00 22.8 1.7 26.3 17.2 22.6 1.7 26.3 17.2 22.4 1.8 27.1 16.1 312 6 306 165 -11.7 0 -11.6 -11.8 11/15/2006 00:20:00 20.7 1.6 24 14.9 20.5 1.6 24 15.3 20.3 1.7 24 15.3 316 8 318 165 -11.6 0 -11.4 -11.8 11/15/2006 00:30:00 21.2 1.5 25.6 17.2 21.1 1.5 25.6 17.2 20.8 1.6 26 16.1 313 6 313 165 -11.6 0 -11.4 -11.8 11/15/2006 00:40:00 21.2 1.7 24.8 15.6 21.1 1.7 24.4 16.1 20.4 1.9 25.6 14.5 310 8 310 165 -11.6 0 -11.4 -11.8 11/15/2006 00:50:00 20.5 2 26.3 15.6 20.3 2.1 26.3 15.3 20 2.2 24.8 14.9 314 7 311 165 -11.5 0 -11.4 -11.8 11/15/2006 01:00:00 19.5 1.7 24 15.6 19.4 1.7 24 15.3 19.2 1.9 24 14.1 317 7 311 165 -11.4 0 -11.2 -11.6 11/15/2006 01:10:00 19.4 2 24.8 14.1 19.2 2.1 24.4 14.1 18.6 1.9 24.8 13.3 314 9 301 165 -11.3 0 -11 -11.4 11/15/2006 01:20:00 20 2.2 27.5 15.3 19.8 2.2 27.5 14.9 19 2.2 26.3 13.3 310 7 319 165 -11.2 0 -11 -11.4 11/15/2006 01:30:00 19.4 2.1 24.8 14.5 19.3 2.1 24.8 14.5 18.1 2 24 13 308 8 291 165 -11.2 0.1 -11 -11.4 11/15/2006 01:40:00 18.7 1.7 23.3 14.1 18.6 1.7 22.9 14.1 17.6 2 23.7 13 309 8 302 165 -11.2 0 -11 -11.4 11/15/2006 01:50:00 17.9 2.1 26.8 12.6 17.8 2.2 26.3 12.2 16.9 2.3 24 11.8 311 11 309 165 -11.1 0 -11 -11.4 11/15/2006 02:00:00 17.1 2 23.3 10.3 16.9 2 23.3 10.7 16.4 2.2 23.3 10.3 314 9 318 165 -11.1 0 -11 -11.4 11/15/2006 02:10:00 18.8 1.7 23.3 14.1 18.6 1.7 22.9 14.1 17.8 1.8 21.8 12.6 312 9 312 165 -11.2 0.1 -11 -11.4 11/15/2006 02:20:00 18 2.2 23.7 13 17.9 2.2 23.3 11.8 16.7 2 22.6 10.7 310 10 319 165 -11.3 0 -11 -11.4 11/15/2006 02:30:00 16.4 1.7 20.6 12.2 16.3 1.7 21 11.8 14.7 1.9 20.6 11.1 308 10 309 165 -11.3 0 -11 -11.4 11/15/2006 02:40:00 19.2 2 24 13 19.1 2.1 23.7 12.6 17.3 2.4 22.6 11.1 307 8 294 165 -11.3 0 -11 -11.4 11/15/2006 02:50:00 19 1.9 23.3 14.1 18.8 1.8 23.3 14.1 17.6 1.8 22.9 13.3 312 11 319 165 -11.4 0 -11.2 -11.6 11/15/2006 03:00:00 18.7 2.2 24.4 13.7 18.5 2.1 24 13.3 17 2.5 24.4 9.9 309 10 319 165 -11.4 0 -11.4 -11.6 11/15/2006 03:10:00 19.2 1.9 24 13.3 19.1 1.9 23.7 13 17.6 2 22.6 13 309 10 310 165 -11.6 0 -11.4 -11.8 11/15/2006 03:20:00 19 1.8 23.7 13 18.9 1.7 23.3 13.3 17.2 2.3 23.7 11.8 308 10 319 165 -11.6 0 -11.4 -11.8 11/15/2006 03:30:00 19.4 2 24.8 12.2 19.3 2 24 12.2 17.2 2 23.7 11.8 307 8 306 165 -11.7 0 -11.4 -11.8 11/15/2006 03:40:00 21.7 1.9 26.3 16.1 21.5 1.8 26 16.1 19.9 2 26.3 14.1 308 10 312 165 -11.7 0 -11.4 -11.8 11/15/2006 03:50:00 23 1.8 27.5 17.9 22.8 1.9 27.1 17.2 22.2 2 27.1 16.1 313 8 305 165 -11.9 0 -11.6 -12 11/15/2006 04:00:00 24.1 2.5 29.1 16.4 24 2.5 29.4 16.8 23.2 2.4 29.4 16.1 311 8 312 165 -12 0 -11.8 -12.2 11/15/2006 04:10:00 24.3 2.2 32.1 17.9 24.2 2.2 31.8 17.9 23.5 2.1 29.8 17.9 311 8 295 165 -12 0 -11.8 -12.2 11/15/2006 04:20:00 24.1 1.9 29.8 19.1 23.9 1.9 29.4 19.1 23.3 2.2 29.8 17.6 312 8 311 165 -12.1 0 -11.8 -12.4 11/15/2006 04:30:00 24.7 2.2 30.6 18.7 24.5 2.3 30.6 18.7 23.4 2.4 29.4 14.5 310 8 319 165 -12 0 -11.8 -12.2 11/15/2006 04:40:00 25.3 2.1 30.9 19.1 25.2 2.1 30.6 18.7 23.7 2.2 29.8 17.2 308 6 309 165 -12 0 -11.8 -12.2 11/15/2006 04:50:00 25.5 1.7 30.9 17.9 25.3 1.7 30.6 17.9 23.6 2.3 29.1 16.1 307 6 300 165 -12.2 0 -12 -12.4 11/15/2006 05:00:00 25.3 1.6 29.1 20.6 25.2 1.7 29.4 20.6 23.5 2.1 28.3 17.2 306 6 308 165 -12.2 0 -12 -12.4 11/15/2006 05:10:00 25.4 1.7 30.2 19.5 25.3 1.8 29.8 19.1 23.5 2.1 29.1 17.9 306 6 304 165 -12.2 0 -12 -12.4 11/15/2006 05:20:00 22.5 2 27.5 16.8 22.4 2.1 27.1 16.8 21.7 2.1 27.1 15.3 311 7 306 165 -12.2 0 -12 -12.4 11/15/2006 05:30:00 23.6 2.2 29.8 17.6 23.5 2.2 29.8 16.8 22.4 2.3 29.1 16.4 309 9 320 165 -12.2 0 -12 -12.4 11/15/2006 05:40:00 22.8 1.9 28.3 17.9 22.7 2 27.9 17.2 22 2.3 26.8 15.6 309 7 300 165 -12.1 0 -11.8 -12.4 11/15/2006 05:50:00 21.8 2 26.8 16.8 21.6 2 26.8 16.8 20.4 2.1 26 14.9 308 9 296 165 -12.2 0 -12 -12.4 11/15/2006 06:00:00 21.6 2.3 26.8 15.6 21.4 2.2 26.8 15.6 20.5 2.5 26.8 13 309 8 305 165 -12.2 0 -12 -12.4 11/15/2006 06:10:00 24.3 1.9 32.4 19.1 24.1 1.9 32.4 19.1 23.4 1.9 29.1 16.8 310 8 297 165 -12.2 0 -12 -12.4 11/15/2006 06:20:00 24.7 2.1 30.6 19.5 24.5 2.2 30.2 18.7 24.1 2.3 30.2 17.9 313 8 307 165 -12.3 0 -12.2 -12.4 11/15/2006 06:30:00 24.6 1.6 30.2 19.9 24.4 1.7 30.2 19.9 23.8 2.1 28.7 17.6 311 7 310 165 -12.3 0 -12.2 -12.4 11/15/2006 06:40:00 24.2 2 29.4 16.8 24 2 28.7 16.8 23.6 1.9 27.9 16.8 312 9 313 165 -12.3 0 -12.2 -12.4 11/15/2006 06:50:00 23.3 2.2 28.7 17.2 23.1 2.2 28.7 16.4 22.6 2.3 29.8 16.8 311 8 319 165 -12.1 0 -11.8 -12.4 11/15/2006 07:00:00 21.8 2.5 27.5 14.5 21.6 2.5 27.5 13.3 20.5 2.7 27.9 14.5 311 10 316 165 -11.9 0.1 -11.6 -12.2 11/15/2006 07:10:00 24.2 2.6 30.6 17.9 24.1 2.7 30.6 17.9 23.3 2.9 31.8 16.1 312 10 313 165 -11.7 0.1 -11.4 -12 11/15/2006 07:20:00 23.7 2.1 29.4 18.3 23.6 2.1 29.4 18.3 22.9 2.3 30.2 16.8 313 9 316 165 -11.7 0.1 -11.4 -11.8 11/15/2006 07:30:00 24 2.5 32.4 16.1 23.9 2.5 32.9 15.3 23.3 2.5 32.1 17.6 314 9 311 165 -11.6 0 -11.4 -11.8 11/15/2006 07:40:00 24.1 2.3 30.2 16.8 24 2.3 30.6 16.8 23.5 2.4 29.1 16.8 315 10 321 165 -11.6 0 -11.4 -11.8 11/15/2006 07:50:00 24.5 2.6 32.1 17.9 24.3 2.7 32.1 18.7 23.7 2.9 31.3 16.4 310 9 301 165 -11.6 0 -11.4 -11.8 11/15/2006 08:00:00 24.1 2.6 30.6 16.1 24 2.6 30.9 15.6 23.7 2.5 29.4 17.6 315 9 310 165 -11.6 0 -11.4 -11.8 11/15/2006 08:10:00 24.7 2.1 29.8 19.5 24.6 2.1 29.4 19.1 23.9 2.5 30.9 18.7 311 8 307 165 -11.5 0 -11.4 -11.8 11/15/2006 08:20:00 24.4 2.4 30.2 16.8 24.3 2.4 29.8 16.4 24 2.5 30.9 16.1 316 9 325 165 -11.4 0 -11.2 -11.6 11/15/2006 08:30:00 25.2 1.8 30.9 19.9 25.1 1.8 31.3 19.1 25 2.1 32.4 19.1 316 8 317 165 -11.4 0 -11.2 -11.6 11/15/2006 08:40:00 24.8 2.1 30.9 19.9 24.6 2.1 30.2 19.5 24.2 2.1 29.4 19.1 312 9 309 165 -11.4 0 -11.2 -11.6 11/15/2006 08:50:00 24.8 2.1 32.1 19.1 24.7 2.1 32.4 18.7 23.8 2.3 29.4 17.9 310 8 294 165 -11.3 0 -11 -11.4 11/15/2006 09:00:00 23.7 2.1 29.4 17.9 23.6 2.2 29.1 17.6 23.2 2.1 29.1 18.7 312 8 309 165 -11.3 0 -11 -11.4 11/15/2006 09:10:00 22.8 1.8 27.9 16.8 22.7 1.9 27.1 16.8 22 1.9 29.1 15.6 311 9 307 165 -11.2 0 -11 -11.4 11/15/2006 09:20:00 24 1.8 28.3 18.7 23.9 1.8 27.9 17.9 23.2 1.9 27.5 16.4 310 8 304 165 -11.1 0 -11 -11.4 11/15/2006 09:30:00 23.5 2.1 29.1 15.6 23.4 2.1 29.1 14.9 22.7 2.2 27.5 16.4 309 7 307 165 -11 0 -10.8 -11.2 11/15/2006 09:40:00 23.2 2 28.7 17.2 23.1 2 28.3 16.8 22.5 2.2 27.9 16.8 312 8 301 165 -10.9 0 -10.8 -11 11/15/2006 09:50:00 23.1 2.4 31.8 16.4 22.9 2.4 30.9 16.4 22.3 2.5 30.9 15.3 312 10 309 165 -10.8 0 -10.6 -11 11/15/2006 10:00:00 23.4 1.8 28.3 18.7 23.2 1.8 27.5 18.3 22.6 1.9 26.8 16.1 311 8 315 165 -10.7 0.1 -10.4 -10.8 11/15/2006 10:10:00 23.3 2 28.3 17.2 23.2 2 27.9 16.8 22.4 2.4 28.3 16.4 311 9 292 165 -10.7 0 -10.6 -11 11/15/2006 10:20:00 24.4 1.7 28.7 20.2 24.3 1.7 28.3 19.5 23.3 2 28.7 16.8 307 7 298 165 -10.6 0.1 -10.4 -10.8 11/15/2006 10:30:00 24 1.9 30.2 17.9 23.9 1.9 30.2 17.9 22.4 2.1 27.5 15.3 305 7 296 165 -10.7 0 -10.6 -11 11/15/2006 10:40:00 23.6 1.8 28.7 19.5 23.6 1.8 28.3 19.1 22 2.1 27.5 15.3 306 7 288 165 -10.6 0 -10.4 -10.8 11/15/2006 10:50:00 22.6 2.4 27.9 15.6 22.5 2.4 27.9 14.5 20.9 2.4 27.5 14.5 308 9 319 165 -10.4 0.1 -10.2 -10.6 11/15/2006 11:00:00 21.1 2.8 27.5 13.3 20.9 2.8 27.5 13.3 19.5 2.8 27.1 11.5 310 11 296 165 -10.3 0.1 -10 -10.6 11/15/2006 11:10:00 20.9 2 27.5 16.1 20.7 2 27.1 15.6 19.9 2.3 26 14.5 311 10 302 165 -10.2 0 -10.2 -10.4 11/15/2006 11:20:00 21.6 2.2 28.3 17.2 21.5 2.2 28.3 16.8 20.9 2.3 30.2 14.9 314 9 295 165 -10.2 0 -10 -10.4 11/15/2006 11:30:00 23.8 2.3 30.6 16.4 23.7 2.3 30.2 15.6 23.4 2.5 30.9 16.1 314 9 308 165 -10.2 0 -10 -10.4 11/15/2006 11:40:00 24.1 2.3 32.1 17.9 24 2.3 32.1 17.6 23.5 2.5 32.4 16.8 313 9 317 165 -10.1 0 -9.7 -10.4 11/15/2006 11:50:00 25.9 2.5 34.4 20.2 25.8 2.5 34.4 20.6 25.3 2.7 32.9 19.1 316 10 310 165 -10 0 -9.7 -10.2 11/15/2006 12:00:00 25.9 2.6 32.9 18.7 25.7 2.6 32.4 18.3 25.4 2.5 32.1 18.7 317 9 325 165 -10 0.1 -9.7 -10.2 11/15/2006 12:10:00 23.6 2.9 29.1 14.1 23.4 2.9 29.1 14.5 23 3.1 30.6 13.3 316 10 313 165 -10 0 -9.7 -10.2 11/15/2006 12:20:00 20.6 2.6 30.9 13.7 20.4 2.6 30.9 13.3 19.3 2.6 29.8 11.8 314 13 307 165 -9.8 0.1 -9.3 -10.2 11/15/2006 12:30:00 20.4 2.9 29.8 14.5 20.3 2.9 30.2 13.3 18.9 3.2 30.2 11.5 312 12 311 165 -9.5 0 -9.3 -9.7 11/15/2006 12:40:00 21.1 2.4 26.3 14.5 20.9 2.4 26 14.5 19.4 2.3 24.4 12.6 309 10 330 165 -9.6 0.2 -9.1 -10.2 11/15/2006 12:50:00 22.4 2.2 28.7 16.1 22.3 2.2 28.3 15.6 21.3 2.2 27.1 13 310 10 302 165 -9.9 0.1 -9.5 -10.2 11/15/2006 13:00:00 20.5 2.8 27.9 12.2 20.3 2.8 27.5 12.2 18.8 2.8 26.8 9.5 312 12 296 165 -9.5 0 -9.3 -9.7 11/15/2006 13:10:00 17.9 2.4 24.4 10.7 17.7 2.4 24.8 11.5 16.2 2.5 23.7 9.5 313 11 306 165 -9.2 0 -9.1 -9.3 11/15/2006 13:20:00 20.6 2.8 28.3 13.3 20.3 2.8 27.9 13 19.7 3.2 30.2 12.2 319 11 328 165 -9.2 0 -9.1 -9.3 11/15/2006 13:30:00 17.9 2.7 26 9.9 17.8 2.7 25.6 9.5 16 3.2 25.2 7.2 316 14 321 165 -9.2 0 -8.9 -9.3 11/15/2006 13:40:00 16.8 2.8 23.7 9.9 16.8 2.7 24 9.5 14.2 2.7 24 6.8 311 15 302 165 -9.1 0 -8.9 -9.1 11/15/2006 13:50:00 16.8 3.1 27.1 8.8 16.5 3.1 27.1 7.2 15.1 3.2 25.2 8.8 323 19 316 165 -9.1 0 -8.9 -9.3 11/15/2006 14:00:00 15.5 2.4 22.6 9.1 15.3 2.3 22.1 8.4 13.8 2.6 19.9 5.7 318 18 305 165 -9.1 0 -8.9 -9.1 11/15/2006 14:10:00 14.7 2.4 21 8.8 14.5 2.4 20.6 8 13.2 2.2 19.1 8 321 19 300 165 -9 0 -8.7 -9.1 11/15/2006 14:20:00 19.8 3.2 27.9 11.8 19.6 3.3 27.9 11.5 18.4 3.3 27.1 9.9 313 13 307 165 -9 0.1 -8.7 -9.1 11/15/2006 14:30:00 19.8 2.5 27.5 14.9 19.5 2.5 26.8 14.5 18.6 2.4 25.6 12.6 319 13 330 165 -9 0 -8.7 -9.1 11/15/2006 14:40:00 19.5 3.1 27.5 11.5 19.4 3.1 27.5 11.5 18.6 3.1 26.8 12.6 319 15 323 165 -9 0 -8.5 -9.1 11/15/2006 14:50:00 17.8 2.2 23.3 12.2 17.4 2.3 23.7 11.8 16.8 2.4 23.3 10.7 325 18 314 165 -8.9 0.1 -8.5 -9.1 11/15/2006 15:00:00 16.6 2.1 22.6 10.3 15.8 2.3 22.1 9.5 15.5 1.9 19.9 10.3 331 19 357 165 -9.2 0 -8.9 -9.7 11/15/2006 15:10:00 15.6 3.5 26.3 8.8 14.7 3.1 24.8 7.2 14.4 3.6 25.2 6.8 338 15 358 165 -9.5 0 -9.3 -9.7 11/15/2006 15:20:00 15.1 3.5 25.6 7.6 14.2 3.1 22.9 7.2 14.4 3.6 24 6.8 337 17 356 165 -9.6 0 -9.3 -9.7 11/15/2006 15:30:00 14.7 2.6 23.3 9.5 13.7 2.2 21.4 8.4 13.8 2.4 20.6 8 334 19 354 165 -9.7 0 -9.5 -10 11/15/2006 15:40:00 14.8 2.6 22.9 9.5 14.5 2.7 22.9 9.1 14 2.6 22.6 8.4 326 17 340 165 -9.8 0 -9.5 -10 11/15/2006 15:50:00 15.5 2.1 21.4 9.9 15.1 2.1 21.8 9.9 14.3 2.1 19.5 9.1 321 17 308 165 -9.8 0 -9.7 -10.2 11/15/2006 16:00:00 16.5 3.5 25.2 8.4 16.1 3.3 26 8.4 15.9 3.5 26.3 8.8 335 12 352 165 -9.9 0 -9.7 -10.2 11/15/2006 16:10:00 14.8 2.2 20.2 8.8 14.6 2.1 21 8.4 13.9 1.9 19.9 8.8 323 13 309 165 -10 0 -9.7 -10.2 11/15/2006 16:20:00 16.4 2.9 26 9.5 15.9 2.9 24.8 7.6 15.1 2.9 24.8 8 336 15 334 165 -10 0 -9.7 -10.2 11/15/2006 16:30:00 16.3 2.1 22.6 10.7 16.1 2.1 21.8 10.3 14.7 2.4 21.8 9.5 315 13 328 165 -10.2 0.1 -9.7 -10.6 11/15/2006 16:40:00 19.7 2 24 14.5 19.6 2 24 14.5 18.7 2.1 23.7 13.7 313 9 305 165 -10.5 0 -10.2 -10.8 11/15/2006 16:50:00 20.5 2.2 25.2 15.3 20.3 2.2 25.2 14.9 19.2 2.6 26 12.6 311 11 303 165 -10.4 0 -10.2 -10.8 11/15/2006 17:00:00 20.6 1.9 27.5 14.9 20.4 1.9 27.1 14.9 19.3 2 26 14.1 311 8 299 165 -10.6 0 -10.4 -10.8 11/15/2006 17:10:00 23 1.7 27.9 18.3 22.8 1.8 27.9 18.3 22.2 2 27.5 16.1 313 8 304 165 -10.7 0.1 -10.4 -11 11/15/2006 17:20:00 23.6 2.8 32.9 14.1 23.5 2.7 32.9 14.1 22.8 3.1 32.4 11.8 315 11 312 165 -10.7 0.1 -10.6 -11 11/15/2006 17:30:00 21.6 4 29.4 11.8 21.5 4 30.2 11.5 20.2 4.1 29.8 9.5 315 12 340 165 -10.4 0 -10.2 -10.8 11/15/2006 17:40:00 19.1 2.9 27.5 11.8 18.9 2.9 28.3 12.2 17.6 3.1 27.1 8.8 321 16 316 165 -10.5 0 -10.2 -10.8 11/15/2006 17:50:00 18.7 2.6 27.1 13.3 18.5 2.7 27.1 12.2 17.3 2.7 24.4 9.1 318 16 331 165 -10.7 0 -10.6 -11 11/15/2006 18:00:00 18.3 3.5 27.9 10.3 17.8 3.5 27.5 10.7 16.7 3.5 27.9 8 327 17 310 165 -10.7 0 -10.6 -11 11/15/2006 18:10:00 18.3 3.2 27.9 11.1 17.6 2.9 26.8 11.1 16.7 3.3 26 8 326 19 352 165 -10.7 0.1 -10.6 -11 11/15/2006 18:20:00 18.8 2.9 25.6 11.1 18.7 2.9 25.6 10.3 16.4 2.9 24 7.6 309 14 302 165 -10.9 0 -10.6 -11.2 11/15/2006 18:30:00 22.3 2.4 30.6 16.1 22.1 2.4 30.6 16.4 20.3 2.4 28.3 13.7 310 11 315 165 -10.9 0 -10.8 -11 11/15/2006 18:40:00 21.6 2.8 29.4 14.9 21.5 2.8 29.4 15.3 20.3 3.3 31.8 13 314 12 302 165 -10.9 0 -10.6 -11.2 11/15/2006 18:50:00 22.6 2.7 31.3 16.1 22.3 2.8 30.6 14.9 22 2.7 30.6 15.3 316 11 293 165 -10.6 0.1 -10.2 -11 11/15/2006 19:00:00 20.6 2.9 27.5 11.8 20.5 2.9 27.1 11.8 18.9 3.1 28.3 12.6 309 13 319 165 -10.6 0 -10.2 -10.8 11/15/2006 19:10:00 22 2.6 31.8 12.2 21.8 2.6 32.1 12.6 21.4 2.6 31.3 14.1 316 14 299 165 -10.6 0.1 -10.4 -10.8 11/15/2006 19:20:00 23 2.5 31.3 16.8 22.8 2.5 31.8 16.4 22.2 2.9 30.6 13.7 317 12 312 165 -10.7 0.1 -10.6 -10.8 11/15/2006 19:30:00 23.8 3.2 35.5 16.8 23.6 3.2 35.2 16.4 22 3.3 32.1 14.1 314 13 308 165 -10.6 0 -10.4 -11 11/15/2006 19:40:00 23.3 3.2 33.2 14.1 23.2 3.2 33.6 13.7 22 3.5 30.9 12.6 319 12 336 165 -10.5 0 -10.2 -10.8 11/15/2006 19:50:00 23.6 2.8 34 17.2 23.4 2.8 34 16.4 22.5 2.8 30.9 15.3 317 13 299 165 -10.5 0 -10.4 -10.8 11/15/2006 20:00:00 19.2 3.5 28.7 11.1 19 3.6 28.7 9.5 17.1 3.6 28.3 8.4 319 18 337 165 -10.4 0 -10.2 -10.6 11/15/2006 20:10:00 19.7 2.6 26 11.8 19.5 2.6 25.6 11.8 18.4 2.9 26.3 9.5 310 13 300 165 -10.4 0 -10.2 -10.6 11/15/2006 20:20:00 19 3.5 30.2 11.1 18.8 3.5 29.4 11.1 18 3.5 27.1 9.9 315 11 301 165 -10.5 0 -10.2 -10.8 11/15/2006 20:30:00 17 2.9 23.7 9.9 16.3 2.8 23.7 9.1 15.7 3.1 24.8 9.1 334 20 355 165 -10.4 0.1 -10.2 -10.6 11/15/2006 20:40:00 17.7 2.8 26 9.5 17.1 2.8 26.3 10.3 17 2.8 25.2 9.9 331 16 348 165 -10.3 0 -10.2 -10.6 11/15/2006 20:50:00 20.2 3.8 31.3 12.2 19.5 4 32.9 12.2 19.5 4 32.4 9.9 337 17 338 165 -10.2 0.1 -10 -10.4 11/15/2006 21:00:00 21.3 3.3 29.8 11.1 21.1 3.5 29.8 11.1 19.6 3.6 30.9 11.8 310 13 315 165 -10.2 0 -10 -10.4 11/15/2006 21:10:00 21.4 3.2 32.9 14.1 21.2 3.1 32.4 14.1 20.1 3.5 31.3 12.2 315 11 312 165 -10.2 0.1 -10 -10.6 11/15/2006 21:20:00 17.6 2.3 23.7 11.5 17.3 2.2 22.9 10.3 16.4 2.5 23.7 10.7 320 14 358 165 -10.4 0.1 -10.2 -10.6 11/15/2006 21:30:00 18.2 2.3 25.2 13 17.6 2.3 26.3 9.5 17.4 2.5 25.2 11.1 336 14 342 165 -10.2 0 -10 -10.4 11/15/2006 21:40:00 19 3.5 31.3 10.7 18.5 3.6 30.6 9.1 17.9 3.6 27.9 10.3 336 12 343 165 -10.1 0 -9.7 -10.2 11/15/2006 21:50:00 18.1 3.2 28.3 9.5 17.2 3.1 29.1 10.7 16.9 3.3 26.8 6.1 336 17 341 165 -10.1 0 -9.7 -10.2 11/15/2006 22:00:00 16.9 2.9 26.3 9.9 16.5 2.9 25.6 9.5 16 2.9 25.2 9.1 330 16 348 165 -10.1 0 -9.7 -10.2 11/15/2006 22:10:00 18.9 2.5 24.8 12.6 18.1 2.5 25.2 11.8 18.1 2.6 25.2 11.5 335 14 338 165 -9.9 0 -9.7 -10.2 11/15/2006 22:20:00 19.1 3.1 29.8 12.6 18.2 2.9 28.7 12.2 18.2 2.9 28.3 11.8 335 14 351 165 -9.9 0 -9.7 -10.2 11/15/2006 22:30:00 17.7 2.4 24 11.5 17.4 2.4 23.7 11.5 16.2 2.7 23.7 8.8 322 14 353 165 -10 0 -9.7 -10.2 11/15/2006 22:40:00 16.7 2.5 24.4 9.9 16.4 2.5 24.8 10.7 15.2 2.7 21.8 8.4 320 15 307 165 -10 0 -9.7 -10.2 11/15/2006 22:50:00 18.5 2.4 24.8 12.6 18.4 2.4 25.2 12.6 17.1 2.5 24.4 9.9 311 12 296 165 -9.9 0.1 -9.7 -10.2 11/15/2006 23:00:00 18.3 2.4 25.2 13.3 18.1 2.4 25.2 13 17 2.4 26 9.5 313 12 298 165 -9.7 0.1 -9.5 -10 11/15/2006 23:10:00 17 2.5 24 11.1 16.8 2.5 23.7 11.5 15.5 2.6 23.7 9.1 319 14 353 165 -9.7 0 -9.5 -10 11/15/2006 23:20:00 17.2 2.4 23.7 11.8 17.1 2.4 23.3 11.5 16 2.5 22.9 9.9 314 14 316 165 -9.7 0 -9.5 -10 11/15/2006 23:30:00 18.8 2.9 27.5 12.6 18.3 2.9 26.8 11.5 17.7 3.1 26.8 10.3 331 15 351 165 -9.5 0 -9.3 -9.7 11/15/2006 23:40:00 16.9 2.5 23.7 10.7 16.7 2.5 25.2 10.7 15.8 2.3 22.6 10.3 326 15 344 165 -9.4 0 -9.3 -9.7 11/15/2006 23:50:00 18.5 3.5 27.5 10.3 18 4 28.7 7.6 17 3.8 27.9 7.6 335 18 344 165 -9.4 0 -9.1 -9.7 11/16/2006 00:00:00 19.6 3.6 34 9.5 18.6 3.3 28.7 9.1 18.6 3.8 31.8 9.9 338 16 1 165 -9.1 0 -8.7 -9.3 11/16/2006 00:10:00 17.3 2.5 23.3 10.3 16.9 2.5 23.3 10.3 16.3 2.5 22.9 9.5 333 13 328 165 -9.2 0 -8.9 -9.3 11/16/2006 00:20:00 18.5 3.2 27.1 11.5 18.2 3.3 27.9 11.5 17.8 3.3 27.1 11.1 333 15 340 165 -9.2 0 -8.9 -9.3 11/16/2006 00:30:00 16.8 2.2 23.7 10.3 16.3 2.2 24.8 10.3 15.6 2.1 21.8 9.9 330 15 350 165 -9.3 0 -9.1 -9.5 11/16/2006 00:40:00 17.9 2.9 27.5 12.2 17.1 2.8 24 11.5 17.1 3.3 29.4 10.3 333 16 318 165 -9.2 0 -8.9 -9.3 11/16/2006 00:50:00 17 2.6 24 10.7 16.1 2.7 24.4 8.4 15.7 2.9 22.9 6.1 334 18 354 165 -9.3 0 -8.9 -9.3 11/16/2006 01:00:00 22 3.3 29.8 12.2 21.8 3.5 29.1 12.2 21.6 3.8 31.3 11.1 336 10 351 165 -9.1 0.1 -8.9 -9.3 11/16/2006 01:10:00 18.2 3.1 27.9 10.7 17.7 3.1 29.1 9.5 17 3.2 28.3 8.4 338 11 333 165 -9.1 0 -8.7 -9.1 11/16/2006 01:20:00 15.2 3.2 24 7.2 14.6 3.2 22.1 7.6 13.3 3.2 21.8 4.9 338 15 3 165 -9.2 0 -8.9 -9.3 11/16/2006 01:30:00 14.3 3.1 22.9 8.8 13.9 3.2 23.7 7.6 13.5 3.1 22.9 6.8 336 15 330 165 -9.2 0 -8.9 -9.3 11/16/2006 01:40:00 12.4 2.4 19.9 6.8 12.1 2.4 19.5 7.2 11.6 2.6 18.7 5.7 331 15 334 165 -9.2 0 -8.9 -9.3 11/16/2006 01:50:00 13.3 2.3 19.9 8.4 13 2.4 20.2 7.6 12.2 2.7 19.1 6.8 322 17 309 165 -9.1 0 -8.9 -9.3 11/16/2006 02:00:00 14.7 2.6 21 6.5 14.4 2.5 20.6 7.6 13.8 2.9 21.4 5.3 329 18 352 165 -9.2 0 -8.9 -9.3 11/16/2006 02:10:00 15 2.3 21.4 8.4 14.8 2.3 21.4 8.4 14 2.5 20.6 4.6 323 13 331 165 -9.2 0 -8.9 -9.3 11/16/2006 02:20:00 16.1 3.1 23.3 8.4 15.6 3.2 23.3 8 15 2.9 22.1 8 334 15 349 165 -9.1 0 -8.9 -9.3 11/16/2006 02:30:00 18.4 2.5 26 11.5 17.6 3.1 25.6 10.3 17.9 2.7 25.6 11.1 341 12 347 165 -9.1 0 -8.9 -9.1 11/16/2006 02:40:00 18.4 2.7 28.3 12.2 17.6 2.7 27.9 11.8 17.8 2.9 27.1 11.8 338 12 346 165 -9.1 0 -8.7 -9.1 11/16/2006 02:50:00 18.5 2.4 26 11.8 18.2 2.5 25.6 12.2 17.9 2.6 24.8 12.2 335 11 331 165 -9 0 -8.7 -9.1 11/16/2006 03:00:00 17.3 2.7 26.3 10.7 16.8 2.8 26 10.3 16.5 2.8 24 9.1 337 13 339 165 -9 0 -8.7 -9.1 11/16/2006 03:10:00 16.4 2.8 26.3 10.3 16.1 2.8 26.3 10.3 15.5 2.9 24.4 9.1 333 14 356 165 -9 0 -8.9 -9.1 11/16/2006 03:20:00 17.5 3.2 27.1 9.5 17.2 3.2 27.1 9.1 16.8 3.3 26.3 9.1 338 10 343 165 -8.9 0 -8.7 -9.1 11/16/2006 03:30:00 15.5 2.6 22.6 9.5 15.1 2.7 23.3 8.8 14.6 2.9 22.6 6.5 330 18 299 165 -8.8 0 -8.5 -8.9 11/16/2006 03:40:00 15 2.7 21.4 8.8 14.8 2.8 21.4 8 14.1 2.7 21 8.4 331 15 329 165 -8.8 0 -8.7 -8.9 11/16/2006 03:50:00 14.8 2.4 20.2 9.1 14.5 2.6 20.6 8.8 13.8 2.4 19.9 8.4 325 16 318 165 -8.8 0 -8.5 -8.9 11/16/2006 04:00:00 13.7 2 18.7 8.4 13.5 2 18.7 8.8 12.7 1.7 17.2 8 323 16 311 165 -8.9 0 -8.5 -9.1 11/16/2006 04:10:00 14.2 2 18.7 9.5 14.1 2.1 18.7 9.1 12.8 2.5 19.1 4.2 321 19 309 165 -8.8 0 -8.5 -8.9 11/16/2006 04:20:00 15.3 2.8 23.3 7.2 15.1 2.9 24.4 7.6 14.3 2.7 21.8 6.5 333 16 349 165 -8.7 0 -8.5 -8.9 11/16/2006 04:30:00 15.5 2.8 26.3 9.1 15.2 2.9 26.8 9.1 14.6 2.6 22.9 8 329 18 313 165 -8.6 0 -8.3 -8.9 11/16/2006 04:40:00 17.4 2.7 25.2 11.1 16.8 2.8 25.6 10.3 16.9 2.9 27.9 9.1 336 13 340 165 -8.5 0 -8.3 -8.7 11/16/2006 04:50:00 14.3 2 19.5 9.1 14 2.1 19.5 6.8 13 2.4 18.7 5.7 326 18 331 165 -8.4 0 -8.3 -8.5 11/16/2006 05:00:00 15 2.9 22.9 8.8 14.8 2.9 23.3 7.2 14.1 3.1 23.3 5.7 329 15 316 165 -8.4 0 -8.1 -8.5 11/16/2006 05:10:00 17 2.4 24.8 11.8 16 3.1 24.4 8.8 16.3 2.8 25.2 8 338 15 339 165 -8.4 0 -8.1 -8.5 11/16/2006 05:20:00 18.5 2.4 24 13.3 17.8 2.6 24.8 10.7 17.9 2.4 24 12.6 343 9 344 165 -8.3 0 -8.1 -8.5 11/16/2006 05:30:00 21.3 3.2 29.1 14.9 20.5 3.6 29.4 10.7 20.8 3.3 29.1 13.7 343 9 351 165 -8.3 0 -8.1 -8.5 11/16/2006 05:40:00 19.8 2.6 26.8 13.3 19.4 2.6 25.2 13 19.4 2.6 27.5 13 341 9 348 165 -8.2 0 -8.1 -8.5 11/16/2006 05:50:00 22.4 3.6 30.9 13 21.9 4.3 32.1 11.1 21.7 3.8 29.4 11.5 340 10 344 165 -8.1 0 -8.1 -8.3 11/16/2006 06:00:00 21.7 2.9 27.9 13.7 21.1 3.5 29.1 12.2 21 3.1 28.7 13.3 340 11 347 165 -8.1 0 -7.9 -8.3 11/16/2006 06:10:00 23.2 3.2 30.9 14.1 23 3.5 32.4 13.7 22.4 3.5 30.2 13 339 10 350 165 -8.1 0 -7.9 -8.3 11/16/2006 06:20:00 21.3 2.5 27.5 14.5 20.3 3.1 27.9 11.1 20.4 2.4 26.8 12.2 344 9 338 165 -8 0 -7.6 -8.1 11/16/2006 06:30:00 22 2.7 29.4 14.5 21.5 3.2 30.9 12.2 20.9 2.9 29.8 12.2 343 7 344 165 -8 0 -7.6 -8.1 11/16/2006 06:40:00 21.9 2.7 29.8 16.1 21.3 3.2 28.3 11.1 20.9 2.8 28.3 15.3 344 8 358 165 -8.1 0 -7.9 -8.3 11/16/2006 06:50:00 22.7 2.4 30.6 14.9 22.2 3.1 31.8 11.5 22.2 2.4 29.8 12.6 342 8 353 165 -8.1 0 -7.6 -8.3 11/16/2006 07:00:00 22.1 2.8 28.3 14.1 21.9 3.1 28.7 14.1 21.2 3.1 27.9 13.7 340 7 344 165 -8.2 0 -7.6 -8.5 11/16/2006 07:10:00 23.4 2.2 28.7 16.8 23.1 2.6 28.7 14.9 22 2.3 27.9 14.5 339 8 358 165 -8.2 0 -8.1 -8.5 11/16/2006 07:20:00 23.7 2.7 31.8 16.1 23.4 2.9 30.6 11.8 23.1 2.8 30.2 14.1 340 9 351 165 -8.2 0 -8.1 -8.5 11/16/2006 07:30:00 22.8 2.4 28.3 14.9 22.2 2.7 28.7 14.1 21.7 2.7 28.3 13.7 341 8 349 165 -8.2 0 -8.1 -8.5 11/16/2006 07:40:00 22.4 1.8 29.1 17.6 22.1 2.2 27.9 16.1 20.9 2.4 26.8 14.1 339 7 1 165 -8.3 0 -8.1 -8.5 11/16/2006 07:50:00 23.2 2.1 29.1 17.9 23 2.4 29.1 16.8 22 2.4 27.1 15.6 339 7 343 165 -8.2 0 -8.1 -8.5 11/16/2006 08:00:00 22.5 2.6 28.3 15.6 22.3 2.7 28.7 14.5 22.4 2.9 27.9 14.1 338 9 338 165 -8.1 0 -7.9 -8.3 11/16/2006 08:10:00 21.6 2.7 29.4 14.9 21.5 2.9 30.9 14.1 21.1 3.1 30.9 12.2 337 9 338 165 -8.2 0 -8.1 -8.3 11/16/2006 08:20:00 20 2.9 25.2 12.2 19.7 2.9 26.3 10.7 19.2 3.1 26 11.8 335 11 349 165 -8.1 0 -7.9 -8.3 11/16/2006 08:30:00 22.2 2.6 29.4 15.3 22.1 2.7 29.1 14.9 21.2 2.7 29.8 14.9 335 8 330 165 -8.1 0 -7.9 -8.3 11/16/2006 08:40:00 21.3 2.3 27.1 14.5 20.9 2.7 27.1 12.2 20.7 2.4 26.8 14.1 339 11 337 165 -8 0 -7.9 -8.3 11/16/2006 08:50:00 22.4 2.4 27.1 15.6 22.3 2.5 27.9 14.9 21.7 2.6 26.8 15.3 335 9 347 165 -8 0 -7.6 -8.1 11/16/2006 09:00:00 22.8 2.4 27.5 16.4 22.8 2.7 28.7 16.1 22.2 2.5 28.7 16.4 338 8 334 165 -8 0 -7.6 -8.1 11/16/2006 09:10:00 23.2 2.5 29.1 14.5 22.6 2.8 29.8 14.5 23.1 2.6 30.2 16.4 340 9 339 165 -7.8 0 -7.4 -8.1 11/16/2006 09:20:00 20.2 2.3 26 15.6 19.6 2.5 25.2 12.6 19.6 2.5 26 14.5 336 11 329 165 -7.6 0 -7.4 -7.6 11/16/2006 09:30:00 20.1 2 25.2 14.1 19.8 2.1 24.8 14.1 19.8 2.2 28.3 13.3 335 9 328 165 -7.5 0 -7.2 -7.6 11/16/2006 09:40:00 20 2.1 25.6 14.5 19.7 2.3 25.2 13 19.4 2.4 25.2 13.3 335 10 333 165 -7.5 0 -7.2 -7.6 11/16/2006 09:50:00 20.9 2.7 29.8 13 20.8 2.8 29.4 13 20.4 2.8 29.4 13 334 9 334 165 -7.2 0 -6.8 -7.4 11/16/2006 10:00:00 22 2.6 28.7 16.4 21.8 2.8 28.7 13.7 21.4 2.7 28.3 14.9 338 8 349 165 -6.9 0.1 -6.6 -7.2 11/16/2006 10:10:00 19.9 2.3 26.8 14.1 19.8 2.3 26.3 13.7 19.2 2.6 27.5 12.2 333 9 336 165 -6.8 0 -6.6 -7 11/16/2006 10:20:00 22.6 2.2 27.9 16.1 22.6 2.3 28.3 16.1 21.2 2.4 27.1 14.1 338 6 327 165 -6.9 0 -6.6 -7 11/16/2006 10:30:00 22.1 2.1 27.1 15.3 22 2.4 28.3 15.3 20.8 2.4 26.3 14.5 338 7 339 165 -6.9 0 -6.6 -7.2 11/16/2006 10:40:00 23 2.4 29.8 14.9 22.8 2.6 29.8 14.5 22.1 2.4 28.7 16.8 335 8 334 165 -7.2 0 -6.8 -7.4 11/16/2006 10:50:00 23.2 2.2 27.9 15.6 23.2 2.4 28.7 15.3 21.7 2.7 27.9 14.5 337 9 344 165 -7.2 0 -6.8 -7.2 11/16/2006 11:00:00 22 2.1 26 14.5 21.5 2.4 26.8 14.5 20.4 2.5 26 12.2 340 9 346 165 -7.1 0 -6.8 -7.2 11/16/2006 11:10:00 20.2 2.4 26.8 13.3 19.7 2.6 27.5 13.3 18.5 2.4 23.7 11.1 338 10 350 165 -7.1 0 -6.8 -7.2 11/16/2006 11:20:00 18.3 2.5 24.4 13 17.5 2.7 24 10.7 16.5 2.4 22.6 10.3 341 10 353 165 -7.1 0 -6.8 -7.2 11/16/2006 11:30:00 18.7 2.8 25.6 12.2 18.6 2.9 25.6 11.8 17.4 3.1 24.8 10.3 337 9 340 165 -6.9 0 -6.8 -7 11/16/2006 11:40:00 20.4 2.2 26 13.3 20.1 2.5 26.3 12.6 19.4 2.2 24 13 338 10 347 165 -6.9 0 -6.8 -7 11/16/2006 11:50:00 19.4 2 24 13.7 19.2 2.2 24.8 13.3 17.9 2.2 23.7 11.1 339 8 340 165 -6.8 0 -6.6 -7 11/16/2006 12:00:00 19.7 2.2 26 13.3 19.3 2.5 25.2 11.8 18 2.2 23.7 11.8 338 9 350 165 -6.8 0 -6.6 -7 11/16/2006 12:10:00 19.3 2.6 25.2 12.6 18.9 2.7 26 11.1 17.5 2.5 22.9 10.3 336 10 344 165 -6.8 0 -6.6 -6.8 11/16/2006 12:20:00 19 2.5 24.4 11.8 18.7 2.5 24.8 11.5 17.1 2.7 25.2 8.8 335 9 339 165 -6.9 0 -6.6 -7 11/16/2006 12:30:00 18.7 2.1 23.3 12.6 18.5 2.2 22.9 13 17.3 2.2 22.1 11.1 333 10 324 165 -6.9 0 -6.6 -7 11/16/2006 12:40:00 18 1.7 22.1 12.2 17.7 1.9 21.8 12.6 16.3 2.2 22.1 11.1 332 12 328 165 -6.8 0 -6.6 -7 11/16/2006 12:50:00 18.1 2.2 22.9 11.5 17.8 2.5 22.6 10.3 16.7 2.4 21.8 10.3 337 10 336 165 -6.7 0 -6.6 -6.8 11/16/2006 13:00:00 18.1 2.3 22.6 11.1 17.7 2.5 23.7 11.1 16.8 2.4 22.9 9.1 338 10 333 165 -6.7 0 -6.4 -6.8 11/16/2006 13:10:00 16.9 2.5 23.3 11.1 16.7 2.5 23.7 11.1 15.7 2.6 22.6 9.1 334 12 330 165 -6.6 0 -6.4 -6.8 11/16/2006 13:20:00 16.4 2.4 21.4 9.1 16.2 2.4 21.4 8.8 15.2 2.5 22.1 9.5 333 11 334 165 -6.5 0 -6.4 -6.8 11/16/2006 13:30:00 15.1 2.2 21 8.8 14.6 2.4 21 8.4 14.3 2.4 19.9 8.4 336 11 331 165 -6.6 0 -6.4 -6.8 11/16/2006 13:40:00 17.7 2 22.9 11.8 17.7 2.2 24 11.8 17.3 2.2 23.3 10.3 337 9 329 165 -6.6 0 -6.4 -6.8 11/16/2006 13:50:00 17.7 1.9 21.8 12.6 17.3 2.3 23.3 10.7 17.4 2.1 22.9 11.8 342 11 336 165 -6.6 0 -6.4 -6.8 11/16/2006 14:00:00 16.5 2.2 24 11.5 16.3 2.2 22.6 11.5 15.7 2.1 21.8 11.1 335 12 316 165 -6.7 0 -6.4 -6.8 11/16/2006 14:10:00 19.1 2.5 26 12.6 18.7 2.6 25.6 11.8 18.1 2.8 25.6 10.3 333 9 332 165 -6.7 0 -6.4 -6.8 11/16/2006 14:20:00 18.3 1.9 22.6 12.2 18.2 2.1 23.7 11.8 17.3 2.3 23.3 11.1 337 9 332 165 -6.6 0 -6.4 -6.8 11/16/2006 14:30:00 17 1.8 21.8 11.5 16.7 2 22.1 10.7 16.1 2 20.6 9.9 337 9 341 165 -6.5 0 -6.1 -6.6 11/16/2006 14:40:00 17.3 2 22.6 11.8 16.8 2.1 22.9 11.5 16.4 2.3 21.8 10.3 341 11 340 165 -6.5 0 -6.1 -6.6 11/16/2006 14:50:00 17.6 1.9 21.8 11.1 17.6 2.1 22.9 10.3 16.6 1.9 21.4 11.1 336 12 327 165 -6.5 0 -6.1 -6.6 11/16/2006 15:00:00 15.7 1.7 19.1 11.5 15.5 1.8 20.2 10.7 14.6 1.7 18.7 10.3 334 11 346 165 -6.5 0 -6.1 -6.6 11/16/2006 15:10:00 16.1 2.2 21 9.9 15.9 2.3 21 9.9 14.9 2.5 20.6 8.4 331 12 310 165 -6.5 0 -6.4 -6.6 11/16/2006 15:20:00 14.9 2.2 22.1 9.9 14.7 2.3 22.1 8.8 13.9 2.4 21.4 6.5 334 12 338 165 -6.4 0 -6.1 -6.6 11/16/2006 15:30:00 16.5 2.2 22.6 9.9 16 2.6 22.9 9.1 15.8 2.4 22.1 9.5 339 12 330 165 -6.3 0 -6.1 -6.6 11/16/2006 15:40:00 16.9 1.6 21 12.6 16.8 1.5 21 12.2 16.3 1.6 21 11.5 331 12 301 165 -6.2 0 -5.9 -6.4 11/16/2006 15:50:00 15.5 2.5 21.4 8.8 15.3 2.7 21 8 14.9 2.5 21.4 9.5 336 10 338 165 -6.1 0 -5.9 -6.4 11/16/2006 16:00:00 15.3 2.4 21 9.1 15 2.4 20.6 7.6 14.7 2.2 19.5 9.1 338 10 339 165 -6.1 0 -5.7 -6.4 11/16/2006 16:10:00 16.7 1.9 22.9 11.1 16.4 2.1 22.6 11.1 15.8 2.1 20.6 10.3 335 10 332 165 -6 0 -5.7 -6.1 11/16/2006 16:20:00 17.4 2.1 22.9 11.1 17.2 2.1 22.6 10.7 16.7 2.2 22.6 11.1 332 9 333 165 -6.1 0 -5.7 -6.4 11/16/2006 16:30:00 16.9 1.9 24 10.7 16.6 2 24.4 9.5 15.9 2.2 21 9.9 333 10 341 165 -6.1 0 -5.7 -6.4 11/16/2006 16:40:00 15.4 2.5 22.1 9.1 14.9 2.6 21.4 8.4 14.2 2.5 21.8 8 338 11 289 165 -6.2 0 -5.9 -6.4 11/16/2006 16:50:00 17.3 2.3 23.3 11.1 16.8 2.4 22.9 9.9 16.5 2.4 21.8 10.3 335 10 330 165 -6.2 0 -5.9 -6.4 11/16/2006 17:00:00 17.6 1.8 22.1 13 17.4 1.8 21.4 12.6 17 1.8 21.8 11.5 331 8 330 165 -6.2 0 -5.9 -6.4 11/16/2006 17:10:00 17.5 2 21.8 12.2 17.3 2 21.8 11.8 16.9 2.2 21.4 11.5 331 9 337 165 -6.2 0 -5.9 -6.4 11/16/2006 17:20:00 19.2 2.3 24 12.2 19 2.3 23.3 11.8 18.8 2.5 25.2 11.8 332 8 330 165 -6.2 0 -5.9 -6.4 11/16/2006 17:30:00 18.8 2.6 25.6 12.2 18.4 2.6 25.6 11.8 18.1 2.7 24.8 10.7 335 11 334 165 -6.1 0 -5.7 -6.4 11/16/2006 17:40:00 18.6 2.6 26.8 9.9 18.1 2.7 26.8 8.4 17.7 2.8 26 7.6 337 11 341 165 -6.1 0 -5.9 -6.4 11/16/2006 17:50:00 18.2 3.1 26 10.3 18 3.2 26.8 10.3 17.3 2.9 24.4 9.9 334 10 349 165 -6.1 0 -5.7 -6.4 11/16/2006 18:00:00 17 2.1 21.8 9.9 16.6 2.1 21.8 10.3 16.2 2.3 23.3 9.5 334 9 332 165 -6 0 -5.7 -6.1 11/16/2006 18:10:00 17.2 2.2 23.7 12.2 16.9 2.6 24.8 8.4 16.6 2.3 23.3 10.7 338 10 340 165 -6 0 -5.7 -6.1 11/16/2006 18:20:00 17.1 2.6 22.1 9.9 16.6 2.6 21 9.5 16.2 2.7 21.4 9.5 337 10 358 165 -5.9 0 -5.7 -6.1 11/16/2006 18:30:00 18.5 2.3 23.7 10.7 18.2 2.5 23.3 11.1 17.6 2.4 22.6 10.3 337 10 336 165 -5.9 0 -5.7 -6.1 11/16/2006 18:40:00 18.2 2.5 23.7 11.5 18 2.6 23.3 10.7 17.8 2.5 24 10.7 339 9 344 165 -5.8 0 -5.7 -5.9 11/16/2006 18:50:00 18.6 2.2 22.9 11.8 18.4 2.4 23.7 10.3 18 2.4 22.9 11.1 337 8 333 165 -5.8 0 -5.5 -6.1 11/16/2006 19:00:00 19.9 2.3 26 13.7 19.8 2.4 26 13 19.7 2.4 26.3 13.3 339 9 349 165 -6 0 -5.7 -6.1 11/16/2006 19:10:00 20.4 1.9 27.1 14.5 20.1 2.2 26 14.1 20.3 1.9 24.4 14.5 340 8 343 165 -6.1 0 -5.7 -6.1 11/16/2006 19:20:00 19.4 2.1 26 14.1 19 2.5 25.2 10.7 19 2.2 26 13.3 340 9 348 165 -6.1 0 -5.7 -6.4 11/16/2006 19:30:00 21.3 1.7 26.8 17.2 21.3 1.9 27.5 14.9 21.3 2 27.9 15.3 338 8 351 165 -6.1 0 -5.7 -6.4 11/16/2006 19:40:00 21 1.7 26.3 16.8 20.7 2 26.8 13.7 21 1.9 27.1 15.6 338 9 339 165 -6.1 0 -5.9 -6.4 11/16/2006 19:50:00 21.5 2.1 26.3 15.6 21.4 2.4 27.5 13.7 21.3 2.4 27.5 14.5 335 9 338 165 -6.1 0 -5.9 -6.4 11/16/2006 20:00:00 21.5 2.1 26.3 14.5 21.4 2.4 27.9 11.8 20.9 2.4 27.9 13.3 337 11 338 165 -6 0 -5.7 -6.1 11/16/2006 20:10:00 19.1 2.3 24 11.5 18.8 2.3 23.3 11.8 17.8 2.1 22.6 11.1 336 8 340 165 -6.1 0 -5.7 -6.1 11/16/2006 20:20:00 19.5 2.7 27.5 11.8 19.2 2.7 26 12.2 18.4 2.9 25.2 9.5 334 9 333 165 -6.1 0 -5.7 -6.1 11/16/2006 20:30:00 20.8 2.2 26.8 14.5 20.4 2.2 26.8 14.1 19.8 2.3 26.8 13 331 8 337 165 -6.1 0 -5.7 -6.4 11/16/2006 20:40:00 20.1 3.1 27.1 11.1 19.9 3.2 26.8 9.9 19.4 3.5 27.9 10.7 333 11 325 165 -6 0 -5.7 -6.1 11/16/2006 20:50:00 19.3 2.3 24.8 13 19.1 2.4 25.2 12.6 18.2 2.7 23.3 11.1 334 9 336 165 -6 0 -5.7 -6.1 11/16/2006 21:00:00 19.1 2.2 24 13.7 18.9 2.2 23.7 13.3 18.3 2.5 24 12.2 334 7 332 165 -6.1 0 -5.9 -6.4 11/16/2006 21:10:00 19.1 2.1 24.4 13 19 2.1 24 13 18.6 2.3 24 12.2 332 10 317 165 -6 0 -5.7 -6.1 11/16/2006 21:20:00 19.9 2.2 24 13.7 19.7 2.3 24.4 12.2 18.3 2.4 23.7 11.1 336 9 339 165 -6.1 0 -5.7 -6.1 11/16/2006 21:30:00 16.8 2.4 21.4 9.9 16.5 2.6 22.9 9.5 15.5 2.6 21.4 8.4 334 11 330 165 -5.9 0.1 -5.7 -6.1 11/16/2006 21:40:00 19.4 1.9 25.6 13 19.1 1.9 26 11.1 18.9 2.2 25.6 12.6 332 9 339 165 -5.8 0 -5.5 -5.9 11/16/2006 21:50:00 20.5 2.6 25.2 13.3 20.3 2.6 24.8 13.3 20 2.8 24.8 11.8 332 9 335 165 -5.8 0 -5.5 -5.9 11/16/2006 22:00:00 18.8 2.6 24.4 11.1 18.6 2.6 24.4 10.7 18.3 2.6 26 11.5 331 10 331 165 -5.8 0 -5.5 -5.9 11/16/2006 22:10:00 19.1 2 24 12.6 18.9 2.2 25.6 11.1 18.7 2.1 24.4 12.6 331 9 330 165 -5.7 0 -5.5 -5.9 11/16/2006 22:20:00 19.4 2.1 23.7 14.5 19.1 2.1 23.7 14.1 18.9 2.2 24.8 14.1 330 9 330 165 -5.6 0 -5.3 -5.7 11/16/2006 22:30:00 19.9 2.2 24.4 13.3 19.6 2.2 24.8 13.3 19.4 2.5 24.4 12.2 328 9 330 165 -5.6 0 -5.5 -5.7 11/16/2006 22:40:00 19.5 2.5 25.6 13.3 19.3 2.5 25.2 13 19.1 2.7 25.2 13 329 9 330 165 -5.4 0 -5.3 -5.7 11/16/2006 22:50:00 20.4 2.1 24.4 15.6 20.2 2.2 25.6 14.1 20.3 2 25.6 15.6 332 8 341 165 -5.2 0.1 -5 -5.5 11/16/2006 23:00:00 22.2 2 26.8 15.3 22 2.1 27.5 14.5 22.1 2.1 27.9 15.3 331 9 330 165 -5.2 0 -4.8 -5.3 11/16/2006 23:10:00 20.3 2.4 26.3 13.3 20.1 2.4 26.3 12.6 19.7 2.6 25.6 12.2 335 9 336 165 -5 0 -4.6 -5.3 11/16/2006 23:20:00 21.4 2.2 27.1 13.7 21.3 2.4 27.5 14.1 20.9 2.4 27.1 13.3 334 9 316 165 -5 0 -4.8 -5.3 11/16/2006 23:30:00 22 2.4 27.1 13.3 21.9 2.4 26.8 13.3 21.8 2.5 26.8 13.7 334 9 336 165 -4.9 0 -4.6 -5.3 11/16/2006 23:40:00 22.1 2.3 28.3 14.9 22 2.4 28.3 14.9 21.7 2.4 27.9 14.5 336 7 344 165 -4.9 0 -4.6 -5 11/16/2006 23:50:00 20.6 2.4 24.8 13.7 20.2 2.7 25.6 12.6 20 2.5 24.4 13.7 337 9 338 165 -4.8 0 -4.6 -5 11/17/2006 00:00:00 21.1 2.4 26 15.3 21.1 2.5 26 14.9 21 2.5 26.3 14.5 335 7 340 165 -4.8 0 -4.6 -5 11/17/2006 00:10:00 21.7 2.3 27.1 14.9 21.5 2.6 28.3 11.8 21.5 2.4 26 14.9 336 9 338 165 -4.7 0 -4.4 -4.8 11/17/2006 00:20:00 22.4 2.1 26.8 17.6 22.4 2.3 27.9 14.5 22.4 2.2 28.3 15.6 337 7 341 165 -4.6 0.1 -4.4 -4.8 11/17/2006 00:30:00 22.2 2 26 14.1 22.2 2.1 26.3 13.7 22 2.1 26 13.7 336 8 339 165 -4.5 0 -4.4 -4.6 11/17/2006 00:40:00 22.3 2.2 27.1 14.1 22.1 2.5 27.9 13.3 21.8 2.6 27.5 12.6 337 8 334 165 -4.5 0 -4.2 -4.6 11/17/2006 00:50:00 22.2 2.4 27.1 15.6 22 2.3 27.5 15.6 21.7 2.6 27.5 15.3 333 8 338 165 -4.6 0 -4.2 -4.6 11/17/2006 01:00:00 19.7 2 24 14.1 19.4 2 24 13.3 18.8 2.2 24 11.8 331 9 328 165 -4.6 0 -4.4 -4.6 11/17/2006 01:10:00 17.5 2.2 23.3 12.6 17.1 2.3 23.7 10.7 16.6 2.1 22.9 11.1 334 9 338 165 -4.5 0 -4.2 -4.6 11/17/2006 01:20:00 20.2 1.8 25.2 14.9 19.8 2.3 26 12.2 19.5 2.1 24.4 13.3 343 7 344 165 -4.3 0 -4.2 -4.6 11/17/2006 01:30:00 21.5 1.9 27.1 15.6 21 2.5 27.9 13 21 2.1 26 14.5 341 9 4 165 -4.3 0 -4.2 -4.4 11/17/2006 01:40:00 21.2 1.8 24.8 14.1 21.1 2.4 26 13.3 20.8 2 25.2 14.5 341 8 350 165 -4.3 0 -3.9 -4.4 11/17/2006 01:50:00 21.2 1.8 26 17.2 21 2.2 27.5 14.9 20.8 2.1 26 15.3 342 7 345 165 -4.3 0 -3.9 -4.4 11/17/2006 02:00:00 20.9 2.1 26 11.8 20.5 2.4 26.3 12.6 20.4 2.4 26.3 13 339 9 340 165 -4.4 0 -4.2 -4.6 11/17/2006 02:10:00 22.3 2.1 26.8 15.6 22.3 2.4 27.1 15.3 21.5 2.4 26.8 15.3 339 6 338 165 -4.5 0 -4.2 -4.6 11/17/2006 02:20:00 20.9 2.7 25.6 13 20.7 2.8 25.2 11.8 19.6 2.7 26 11.8 337 8 338 165 -4.4 0 -4.2 -4.6 11/17/2006 02:30:00 21.7 2.3 26 14.1 21.6 2.8 27.9 13.3 20.8 2.2 25.2 13.7 341 8 343 165 -4.3 0 -4.2 -4.6 11/17/2006 02:40:00 20.8 1.9 24.4 14.9 20.5 1.9 24.8 14.9 20.1 2.2 24.8 14.1 333 8 332 165 -4.3 0 -3.9 -4.6 11/17/2006 02:50:00 22.2 2.2 27.5 17.2 21.9 2.3 27.5 16.1 21.7 2.5 27.1 16.4 335 8 337 165 -4.3 0 -3.9 -4.6 11/17/2006 03:00:00 23 2.3 29.4 16.8 22.8 2.5 30.6 15.3 22.7 2.4 29.1 15.6 336 8 350 165 -4.4 0 -4.2 -4.6 11/17/2006 03:10:00 23.1 2.1 27.5 16.8 22.8 2.4 29.1 16.1 22.8 2.4 27.9 15.6 338 8 349 165 -4.4 0 -3.9 -4.6 11/17/2006 03:20:00 22.1 2 27.9 16.4 21.8 1.9 27.1 16.4 21.6 2.2 27.9 14.9 333 8 333 165 -4.4 0 -4.2 -4.6 11/17/2006 03:30:00 20.2 2.4 25.6 14.5 19.9 2.5 26.3 11.1 20.2 2.6 27.5 15.6 332 10 334 165 -4.4 0 -3.9 -4.6 11/17/2006 03:40:00 18.7 2.1 24 13.7 18.5 2.3 23.7 11.8 18.5 2.2 24 13 335 11 349 165 -4.3 0 -3.9 -4.6 11/17/2006 03:50:00 19 1.9 24 13.7 18.7 2.1 24 11.5 18.5 2.1 24.4 11.5 325 14 300 165 -4.3 0 -3.9 -4.4 11/17/2006 04:00:00 20 2.3 26.3 13.3 19.9 2.3 26 13.3 19.1 2.4 26.3 13 318 12 292 165 -4.3 0 -3.9 -4.6 11/17/2006 04:10:00 19.9 2.5 25.6 11.8 19.7 2.6 26 12.2 19.1 2.7 26.8 10.3 319 13 344 165 -4.3 0 -3.9 -4.4 11/17/2006 04:20:00 19.7 2.3 25.6 13.7 19.4 2.3 25.2 12.2 18.7 2.4 24 10.3 319 13 307 165 -4.2 0 -3.9 -4.4 11/17/2006 04:30:00 20.7 2.2 29.8 14.9 20.6 2.2 29.4 15.3 19.4 2.3 28.7 15.3 312 13 312 165 -4 0 -3.7 -4.2 11/17/2006 04:40:00 20.8 2.1 26.8 15.6 20.6 2.1 26.3 14.9 19.9 2.4 26.3 14.9 319 12 313 165 -3.9 0 -3.5 -4.2 11/17/2006 04:50:00 19.2 2.2 24 12.6 19.1 2.2 24 12.2 18.1 2.4 24.4 12.6 318 13 326 165 -4 0.1 -3.5 -4.4 11/17/2006 05:00:00 19 1.9 25.6 13.7 18.8 1.9 26 14.1 18.1 2.2 24 12.2 325 13 309 165 -4 0.1 -3.7 -4.4 11/17/2006 05:10:00 19.9 2.5 27.1 11.1 19.3 2.7 25.2 8.4 19.7 2.6 25.6 12.2 338 12 316 165 -4 0 -3.7 -4.4 11/17/2006 05:20:00 19.1 2.3 27.1 14.1 18.9 2.3 25.2 14.1 18.4 2.8 26 11.5 327 17 354 165 -4 0 -3.5 -4.2 11/17/2006 05:30:00 18.4 2 23.3 13.3 18.3 2 22.9 13.3 18.1 2.2 25.6 12.6 327 12 323 165 -4 0 -3.7 -4.2 11/17/2006 05:40:00 18.3 1.8 24.4 13 18.1 1.8 24.4 12.2 17.2 2.3 24 10.7 318 11 327 165 -4 0 -3.7 -4.2 11/17/2006 05:50:00 16.7 2.2 22.9 11.5 16.5 2.2 24.4 11.5 15.7 2.4 22.1 9.5 325 12 338 165 -4 0 -3.7 -4.2 11/17/2006 06:00:00 17.2 2.5 24.4 11.1 16.7 2.6 24.4 10.3 16.2 2.6 23.7 8.8 331 14 339 165 -4 0 -3.5 -4.2 11/17/2006 06:10:00 18.1 2.8 26.8 11.5 17.7 3.1 27.5 10.3 17.6 2.8 27.1 11.1 333 13 351 165 -3.9 0.1 -3.5 -4.2 11/17/2006 06:20:00 17.1 2.2 24 11.5 16.5 2.2 24.4 12.2 16.6 2.5 24.4 11.5 334 14 332 165 -3.8 0 -3.3 -3.9 11/17/2006 06:30:00 17.5 2.2 22.6 12.2 16.9 2.6 23.7 10.3 17.3 2.4 23.3 12.6 338 11 338 165 -3.7 0 -3.5 -3.9 11/17/2006 06:40:00 18 2.6 24.8 9.9 17.6 2.8 24 9.5 17.6 2.8 24.8 9.5 335 11 315 165 -3.7 0 -3.5 -3.9 11/17/2006 06:50:00 19.1 2.9 27.1 10.7 18.9 2.9 27.5 10.7 19.2 3.1 27.9 10.3 334 11 344 165 -3.7 0 -3.3 -3.7 11/17/2006 07:00:00 20.3 2.2 25.6 15.3 19.9 2.6 26 11.5 20.2 2.5 25.6 13.3 338 10 347 165 -3.6 0 -3.3 -3.7 11/17/2006 07:10:00 18 2.8 25.2 9.1 17.5 2.8 25.2 8 17.6 3.1 25.2 8.8 337 11 351 165 -3.6 0 -3.3 -3.7 11/17/2006 07:20:00 20.1 3.3 28.7 11.8 19.9 3.3 28.7 11.8 19.7 3.3 28.3 11.5 333 9 328 165 -3.5 0 -3.3 -3.5 11/17/2006 07:30:00 20 2.4 25.6 14.9 19.8 2.5 25.6 13.7 19.8 2.7 26 13.3 334 9 349 165 -3.4 0 -3 -3.5 11/17/2006 07:40:00 20.5 2.4 28.7 13.3 20.4 2.5 28.3 13.3 20.4 2.4 27.1 13.3 334 9 323 165 -3.3 0 -3 -3.5 11/17/2006 07:50:00 22.7 2.4 29.8 16.1 22.6 2.4 29.8 16.1 22.5 2.5 30.2 15.6 331 9 317 165 -3.1 0 -2.8 -3.3 11/17/2006 08:00:00 21.6 3.1 29.1 14.1 21.4 3.2 29.4 13 21.3 3.2 28.3 13.3 333 10 308 165 -3.1 0 -2.6 -3.3 11/17/2006 08:10:00 21.1 2.7 27.5 13 21 2.7 27.5 12.2 20.9 2.8 27.9 11.1 333 9 332 165 -3.3 0 -2.8 -3.5 11/17/2006 08:20:00 21.7 2.7 32.9 16.1 21.5 2.7 32.4 16.1 21 2.9 31.8 11.5 329 10 326 165 -3.6 0.1 -3 -3.9 11/17/2006 08:30:00 23.3 2.9 30.6 15.3 23.2 3.1 30.2 15.3 22.8 3.1 29.8 14.9 332 8 337 165 -3.8 0 -3.5 -3.9 11/17/2006 08:40:00 23.2 2.6 29.8 15.3 23 2.6 29.4 13.7 22.5 2.7 29.1 15.3 333 7 341 165 -3.9 0 -3.5 -3.9 11/17/2006 08:50:00 22.6 2.1 27.1 14.5 22.4 2.2 27.1 14.5 21.7 2.2 26.3 15.6 335 9 350 165 -3.9 0 -3.5 -4.2 11/17/2006 09:00:00 23.2 2.5 27.9 15.3 23.3 2.7 28.3 14.5 22 2.5 27.1 14.1 337 7 340 165 -3.8 0 -3.5 -3.9 11/17/2006 09:10:00 23.9 2.8 30.2 15.6 23.7 2.9 30.6 14.1 23.3 2.9 29.8 14.9 336 7 332 165 -3.7 0 -3.5 -3.9 11/17/2006 09:20:00 23.7 2.9 30.6 13.7 23.8 2.9 29.8 14.5 22.7 2.7 29.4 14.1 337 6 341 165 -3.7 0 -3.3 -3.9 11/17/2006 09:30:00 22.9 2.4 30.2 16.4 22.7 2.8 30.2 11.8 21.9 2.5 27.9 13 336 9 334 165 -3.7 0 -3.5 -3.9 11/17/2006 09:40:00 19.9 2.6 27.1 13 19.9 2.7 26.3 13 19.2 2.6 25.6 13 333 10 338 165 -3.6 0 -3.3 -3.5 11/17/2006 09:50:00 21.6 2.7 28.3 12.2 21.5 2.7 27.9 12.2 21.2 2.8 27.5 13 335 8 326 165 -3.5 0 -3.3 -3.5 11/17/2006 10:00:00 21 2.3 26.3 14.5 20.8 2.3 26.3 14.5 20.3 2.5 26 13 330 9 314 165 -3.5 0 -3.3 -3.5 11/17/2006 10:10:00 19.6 2.4 29.8 13 19.4 2.5 29.1 13.3 18.9 2.6 26.3 12.2 331 10 338 165 -3.4 0 -3.3 -3.5 11/17/2006 10:20:00 21.9 2.6 27.5 13.3 21.7 2.7 28.3 14.1 20.7 2.9 27.1 12.6 331 8 330 165 -3.4 0 -3.3 -3.5 11/17/2006 10:30:00 21.5 2.2 26.8 14.9 21.2 2.2 26 14.1 20.5 2.4 26.8 12.2 330 8 316 165 -3.4 0 -3.3 -3.5 11/17/2006 10:40:00 21.3 2.7 27.9 14.1 21 2.7 27.1 14.1 20.3 2.8 27.1 12.2 329 9 333 165 -3.3 0 -3 -3.5 11/17/2006 10:50:00 19.7 2.6 25.6 12.6 19.5 2.6 26 13 18.3 2.9 25.2 11.8 327 9 330 165 -3.2 0 -3 -3.3 11/17/2006 11:00:00 18.5 3.2 26.3 7.6 18.1 3.2 26 7.6 17.2 3.5 26.3 6.5 326 11 321 165 -3 0 -2.8 -3.3 11/17/2006 11:10:00 21.8 2.7 29.8 13.3 21.6 2.7 30.6 13.3 21 3.1 30.6 12.2 328 9 335 165 -2.8 0 -2.6 -3 11/17/2006 11:20:00 22.3 2.8 29.8 15.3 22 2.8 29.4 15.3 21.3 2.8 27.5 14.9 330 9 342 165 -2.9 0 -2.6 -3 11/17/2006 11:30:00 20.8 2.5 28.3 14.9 20.4 2.6 27.5 14.1 19.7 2.5 26 14.1 333 10 330 165 -2.8 0 -2.6 -3 11/17/2006 11:40:00 19.7 2.9 29.4 12.6 19.5 2.8 28.3 12.2 18.3 2.9 27.9 11.1 329 9 323 165 -2.6 0.1 -2.1 -2.8 11/17/2006 11:50:00 19.3 2.5 26 13.3 18.9 2.7 26 11.8 17.9 2.7 25.2 10.7 327 12 336 165 -2.1 0.2 -1.7 -2.6 11/17/2006 12:00:00 17.6 2.7 26.3 9.5 17.3 2.8 26 9.1 16.4 2.8 23.7 9.9 328 12 324 165 -2 0 -1.7 -2.1 11/17/2006 12:10:00 20.2 3.2 26.8 12.6 19.8 3.3 26 10.3 19.2 3.3 26.3 11.8 332 9 327 165 -1.9 0.1 -1.7 -2.1 11/17/2006 12:20:00 20.9 2.5 28.7 15.3 20.6 2.7 27.9 13 20 2.7 27.1 13.3 336 10 329 165 -2.1 0 -1.9 -2.1 11/17/2006 12:30:00 20.6 2.7 27.9 14.5 20 3.1 27.9 11.1 19.6 2.8 27.9 14.5 337 11 325 165 -1.9 0 -1.7 -2.1 11/17/2006 12:40:00 20.8 2.6 26.8 14.1 20.5 2.8 27.9 13 20.4 2.9 27.5 13 337 10 334 165 -1.8 0 -1.7 -1.9 11/17/2006 12:50:00 21.1 2.6 27.1 14.1 20.8 2.7 26.8 14.1 20.7 2.8 26.8 13.3 333 9 344 165 -1.7 0 -1.4 -1.9 11/17/2006 13:00:00 17.9 2.8 25.6 11.8 17.6 3.1 25.2 8 17 3.1 24 9.5 336 9 329 165 -1.6 0 -1.2 -1.9 11/17/2006 13:10:00 17 2.5 25.2 10.7 16.8 2.6 24.4 9.1 16.5 2.7 25.6 8.4 334 10 328 165 -1.7 0 -1.4 -1.9 11/17/2006 13:20:00 17.6 2.2 24 13.3 16.7 2.5 24 10.7 16.7 2.3 23.7 9.9 336 15 342 165 -1.8 0 -1.7 -2.1 11/17/2006 13:30:00 16 2.5 22.9 10.7 15.8 2.6 23.7 9.9 15 2.8 24.4 8.8 330 12 343 165 -1.8 0 -1.4 -1.9 11/17/2006 13:40:00 18.3 2.7 26.3 9.5 18.2 2.8 28.3 9.1 17.2 3.1 26.8 8 326 12 344 165 -1.6 0.1 -1.4 -1.9 11/17/2006 13:50:00 17.7 2.9 24 10.3 17.5 2.8 24 11.1 16.4 2.9 22.9 9.1 326 11 337 165 -1.6 0 -1.2 -1.7 11/17/2006 14:00:00 18.4 2.6 24.4 11.1 18.1 2.6 24 11.5 17.1 3.2 24.4 6.8 327 11 334 165 -1.2 0.2 -0.8 -1.4 11/17/2006 14:10:00 17.4 2.6 25.2 12.2 17.2 2.6 26 11.8 16.4 2.7 24 8.8 330 11 328 165 -1 0.2 -0.5 -1.4 11/17/2006 14:20:00 16.5 2.2 22.1 9.9 16.3 2.1 22.1 10.3 15.4 2.4 21 9.5 327 9 331 165 -1.4 0.2 -1.2 -1.9 11/17/2006 14:30:00 18.5 2.2 25.6 12.6 18.1 2.4 25.6 10.3 18 2.4 24.8 11.1 331 11 316 165 -1.4 0.1 -1.2 -1.9 11/17/2006 14:40:00 16.7 2.8 24.4 9.9 16.5 2.9 24.4 9.5 15.9 3.1 24.4 8.8 329 10 336 165 -1.2 0 -0.8 -1.4 11/17/2006 14:50:00 15.7 2.2 21.8 9.9 15.2 2.2 22.1 9.9 14.3 2.3 19.9 8.4 333 10 344 165 -1.2 0 -0.8 -1.4 11/17/2006 15:00:00 15.7 2.4 22.9 10.3 15.4 2.5 22.9 8 14.7 2.7 22.6 6.8 330 12 325 165 -1.3 0 -1 -1.4 11/17/2006 15:10:00 15.5 2 20.6 11.1 15 2.1 21 9.9 14.8 2.3 21.4 9.9 336 12 336 165 -1.4 0 -1.2 -1.4 11/17/2006 15:20:00 15.9 2 21.8 10.7 15.6 2.2 22.1 9.9 15 2.1 21.8 8.8 335 12 313 165 -1.4 0 -1.2 -1.4 11/17/2006 15:30:00 16.3 2.2 23.3 10.3 15.8 2.6 22.1 8.4 15.5 2.2 21.8 10.7 334 13 316 165 -1.4 0.1 -1.2 -1.9 11/17/2006 15:40:00 17 2.1 22.6 11.8 16.8 2.2 23.3 10.3 16.3 2.3 22.9 9.9 334 9 334 165 -2 0 -1.4 -2.1 11/17/2006 15:50:00 18.2 3.3 27.1 11.1 17.9 3.3 26.8 10.7 17.5 3.5 26.3 8.8 331 10 333 165 -2 0 -1.7 -2.1 11/17/2006 16:00:00 16.1 2.5 23.7 10.7 15.7 2.6 23.7 9.1 15.3 2.6 23.7 9.1 334 13 355 165 -1.8 0 -1.7 -2.1 11/17/2006 16:10:00 14.2 2.3 19.5 8 14 2.3 19.1 6.5 13.2 2.4 19.5 6.1 330 12 342 165 -2.1 0 -1.4 -2.4 11/17/2006 16:20:00 14.9 2.2 21.8 8.4 14.7 2.3 22.6 9.1 14.3 2.3 20.6 9.5 334 11 329 165 -2.2 0 -1.9 -2.4 11/17/2006 16:30:00 16.3 2.6 24 10.3 15.9 2.6 24.4 9.5 15.4 2.6 22.6 9.5 331 13 314 165 -2.4 0.1 -1.9 -2.6 11/17/2006 16:40:00 16.7 3.1 24.8 9.5 16.5 3.1 24.4 9.1 15.6 3.2 22.9 6.5 328 13 333 165 -2.2 0 -1.9 -2.6 11/17/2006 16:50:00 16.1 2.7 22.1 8 15.8 2.7 22.6 6.8 15 2.8 21.4 8 327 10 328 165 -2.3 0 -1.9 -2.6 11/17/2006 17:00:00 13.9 2.6 20.6 7.6 13.8 2.6 20.6 8 12.8 2.6 19.5 6.1 325 12 332 165 -2.2 0 -1.9 -2.6 11/17/2006 17:10:00 15.4 2.5 24 8.8 15.2 2.5 23.3 9.1 14.2 2.6 23.3 8 327 13 350 165 -2.2 0 -1.9 -2.6 11/17/2006 17:20:00 15.8 2.9 23.7 7.6 15.7 2.9 23.3 8 14.5 3.1 22.1 6.1 323 12 307 165 -2.2 0 -1.9 -2.6 11/17/2006 17:30:00 15.2 2.4 21.8 8.8 15 2.4 21.4 9.1 13.9 2.6 21 6.8 326 13 327 165 -2.2 0 -1.9 -2.4 11/17/2006 17:40:00 14.2 2.5 21.8 8 14.1 2.5 21.8 7.6 13 2.5 21.8 6.8 324 13 334 165 -2.3 0 -1.9 -2.6 11/17/2006 17:50:00 13.1 2.8 20.2 7.2 12.9 2.8 20.2 6.8 11.2 2.8 19.9 6.1 326 15 319 165 -2.4 0 -1.9 -2.6 11/17/2006 18:00:00 14.1 2.8 21 6.1 14 2.9 22.6 6.5 12.3 2.9 20.6 6.1 323 14 344 165 -2.3 0 -1.9 -2.6 11/17/2006 18:10:00 13.9 2.7 21.4 6.1 13.7 2.7 21.4 6.1 12.3 2.8 21.4 4.6 326 15 316 165 -2.2 0 -1.9 -2.6 11/17/2006 18:20:00 13 2.3 18.7 4.9 12.9 2.2 19.1 5.3 11.6 2.6 18.3 5.3 323 15 330 165 -2.4 0 -1.9 -2.6 11/17/2006 18:30:00 10.8 2.1 17.2 5.3 10.7 2.1 16.8 5.3 9.4 2.3 16.4 3 321 18 328 165 -2.6 0 -2.1 -2.8 11/17/2006 18:40:00 12 2.4 19.5 6.1 11.8 2.4 19.1 5.7 10.6 2.4 19.5 3.8 327 13 315 165 -2.5 0.1 -2.1 -2.8 11/17/2006 18:50:00 10.2 2.6 17.2 3.8 10 2.7 17.2 2.6 8.2 2.9 16.1 1.9 321 19 314 165 -2.6 0 -2.1 -2.8 11/17/2006 19:00:00 10.1 2.1 15.3 4.9 10 2.1 15.6 4.9 8.7 2.2 14.9 4.2 319 17 313 165 -2.8 0 -2.4 -2.8 11/17/2006 19:10:00 12.3 2.1 19.5 8 12.1 2.1 18.7 8 11.1 2.1 17.6 6.1 326 13 341 165 -2.8 0 -2.6 -2.8 11/17/2006 19:20:00 12.1 2.3 17.6 6.8 11.8 2.3 17.2 7.2 11.4 2.1 16.8 6.8 329 14 307 165 -2.6 0.1 -2.1 -2.8 11/17/2006 19:30:00 14.2 2.6 20.6 7.2 13.9 2.6 20.2 6.8 13.4 2.6 19.1 6.8 332 9 325 165 -2.2 0.2 -1.9 -2.6 11/17/2006 19:40:00 13.5 2.2 19.5 8.4 13.1 2.2 19.1 7.6 12.4 2.2 17.6 6.5 331 12 339 165 -2.1 0 -1.9 -2.4 11/17/2006 19:50:00 14.2 2 21 9.5 13.9 2.1 20.6 9.5 13.6 2.1 19.5 9.1 336 11 327 165 -2.3 0 -1.9 -2.6 11/17/2006 20:00:00 13.2 1.8 19.1 9.1 12.9 2 19.5 7.6 12.7 2 19.9 8.4 333 12 317 165 -2.3 0.1 -1.9 -2.6 11/17/2006 20:10:00 12.4 1.8 17.2 7.6 11.9 1.9 16.4 6.8 11.9 2 17.2 8 332 13 344 165 -2.6 0 -2.1 -2.8 11/17/2006 20:20:00 13 1.8 19.1 8.4 12.8 1.8 18.3 8.8 12.5 2 19.5 7.6 332 12 354 165 -2.8 0 -2.6 -2.8 11/17/2006 20:30:00 11.7 1.7 17.2 7.2 11.6 1.7 16.4 7.2 10.7 1.7 15.6 6.5 326 14 324 165 -2.8 0 -2.4 -2.8 11/17/2006 20:40:00 12.5 1.7 17.6 8 12.1 1.8 18.3 7.6 12.1 1.9 17.9 7.6 336 12 344 165 -2.6 0.1 -2.1 -2.8 11/17/2006 20:50:00 13.2 2.5 21.8 8.4 13.1 2.6 21 7.6 12.8 2.5 20.2 7.2 333 11 338 165 -2.4 0 -2.1 -2.8 11/17/2006 21:00:00 13.1 2.5 19.5 8.4 12.5 2.5 19.5 6.1 12.8 2.6 19.5 8.4 333 13 344 165 -2.5 0.1 -2.1 -2.8 11/17/2006 21:10:00 12.9 2.3 19.9 8 12.5 2.5 19.5 7.2 12.3 2.3 21 7.2 335 13 320 165 -2.5 0 -2.1 -2.6 11/17/2006 21:20:00 14.5 2.2 20.2 8.8 14.1 2.3 20.2 8.4 14.4 2.3 19.9 8.8 337 10 339 165 -2.3 0 -2.1 -2.6 11/17/2006 21:30:00 13.6 1.9 19.5 9.9 13.3 1.9 18.7 7.6 13.4 1.9 19.9 9.1 339 11 333 165 -2.4 0.1 -1.7 -2.8 11/17/2006 21:40:00 14.3 1.8 21.4 8.8 13.8 2.4 22.6 6.1 14.3 1.7 19.1 9.9 343 8 343 165 -2.4 0.2 -1.9 -2.8 11/17/2006 21:50:00 12.8 1.7 17.2 8 12.4 1.8 17.6 7.2 12.5 2.1 17.9 6.8 335 13 339 165 -2.4 0.2 -1.9 -2.8 11/17/2006 22:00:00 13.2 1.7 17.2 7.6 12.8 2 17.9 7.6 12.7 1.7 17.9 8 336 11 347 165 -2.6 0 -2.6 -2.8 11/17/2006 22:10:00 15.4 2 22.6 10.3 14.9 2.1 21 8 15.2 2.3 22.9 9.9 340 9 341 165 -2.8 0 -2.4 -2.8 11/17/2006 22:20:00 14.6 2 21 9.1 14.4 2.1 21.8 9.1 14.5 2.2 20.6 8.4 337 9 344 165 -2.8 0 -2.4 -3 11/17/2006 22:30:00 15.1 2.5 21 8.4 14.9 2.5 21 8.4 15.2 2.6 21.4 7.6 335 10 338 165 -2.6 0.1 -2.6 -2.8 11/17/2006 22:40:00 14.9 1.4 18.3 10.7 14.9 1.5 18.7 10.7 14.6 1.7 19.1 9.1 337 8 342 165 -2.5 0 -2.4 -2.8 11/17/2006 22:50:00 15.1 1.7 19.1 11.1 14.8 2 18.7 8 14.3 1.7 19.5 10.3 336 9 337 165 -2.6 0 -2.1 -2.8 11/17/2006 23:00:00 15.1 1.5 18.7 11.5 14.8 1.7 18.7 8.8 14.6 1.7 18.3 9.9 336 9 333 165 -2.8 0 -2.4 -3 11/17/2006 23:10:00 14.3 1.9 19.1 9.1 14.1 1.8 18.7 8.8 13.6 2 17.9 8.4 332 9 326 165 -2.7 0 -2.4 -2.8 11/17/2006 23:20:00 13.9 2 18.3 9.5 13.7 2.1 18.3 9.5 13 2.1 18.3 8 333 10 332 165 -2.6 0 -2.1 -2.8 11/17/2006 23:30:00 12.9 1.7 17.6 6.8 12.6 1.8 17.2 6.5 11.9 1.8 16.4 6.8 334 9 321 165 -2.7 0 -2.4 -2.8 11/17/2006 23:40:00 12 1.8 17.2 8 11.8 1.8 16.8 6.8 11.2 1.7 14.9 6.5 335 10 342 165 -2.7 0.1 -2.1 -3 11/17/2006 23:50:00 11.6 1.9 16.4 7.6 11.3 1.9 16.1 6.8 10.4 1.9 15.6 6.1 336 10 322 165 -2.8 0 -2.6 -3 11/18/2006 00:00:00 10.7 1.8 14.9 6.1 10.4 1.8 14.1 5.7 9.5 1.9 14.5 5.3 335 12 339 165 -3 0.1 -2.6 -3.3 11/18/2006 00:10:00 11.9 1.5 15.6 7.2 11.7 1.5 15.6 7.6 11.3 1.4 15.3 6.8 337 9 333 165 -2.6 0.2 -2.6 -3 11/18/2006 00:20:00 11 1.7 14.9 5.7 10.8 1.8 14.9 5.7 9.8 2 14.5 4.6 333 11 330 165 -2.6 0 -2.1 -2.8 11/18/2006 00:30:00 10.4 2 14.9 3.8 10.1 2.1 14.5 3.4 9.2 2.3 14.1 1.1 340 12 356 165 -2.9 0 -2.6 -3 11/18/2006 00:40:00 12.3 1.8 16.8 6.8 12 1.9 16.4 6.8 11.5 1.7 15.6 7.2 338 9 335 165 -3.2 0 -2.6 -3.5 11/18/2006 00:50:00 11.5 2.7 17.6 5.7 11.4 2.6 16.8 5.3 10.5 3.2 18.3 3.4 328 12 334 165 -3.2 0.1 -2.8 -3.5 11/18/2006 01:00:00 9.7 2.1 15.6 5.3 9.6 2.2 15.3 4.9 8.3 2.3 13.7 2.6 327 13 334 165 -3.3 0 -3 -3.5 11/18/2006 01:10:00 8 2 14.9 4.6 7.6 2.1 13.7 3.4 6.9 1.7 13.3 3.4 335 17 312 165 -3.4 0 -3 -3.5 11/18/2006 01:20:00 9.4 2.2 13.7 3.8 9.3 2.3 14.5 3.4 7.7 2.4 13.3 3 326 15 339 165 -3.4 0 -3 -3.5 11/18/2006 01:30:00 9.5 1.7 13.7 4.9 9.3 1.7 13.3 4.2 8.1 1.7 11.8 3.4 329 12 310 165 -3.1 0.1 -2.8 -3.5 11/18/2006 01:40:00 10.1 1.8 14.1 5.3 10 1.8 14.5 4.9 8.8 1.9 13.3 3 331 11 336 165 -3.2 0 -2.8 -3.5 11/18/2006 01:50:00 9.3 2.3 14.5 3 9 2.3 14.5 3.8 7.5 2.6 12.6 1.1 336 17 330 165 -3.5 0.1 -3 -3.7 11/18/2006 02:00:00 9.9 2.1 14.9 5.3 9.6 2.1 14.5 5.3 8.8 2.1 14.5 4.6 333 10 339 165 -3.6 0 -3.3 -3.7 11/18/2006 02:10:00 10 1.9 14.5 5.3 9.8 1.9 14.1 4.2 9.2 2.1 13.3 3.4 329 12 332 165 -3.2 0.1 -2.8 -3.5 11/18/2006 02:20:00 8.1 1.7 12.6 4.2 8.1 1.7 12.6 3.8 7 1.7 13 3.4 323 13 338 165 -3.1 0 -2.6 -3.3 11/18/2006 02:30:00 7 1.4 11.5 4.2 6.9 1.3 10.7 3.4 6.2 1.2 10.3 3.4 321 15 333 165 -3 0 -2.8 -3.3 11/18/2006 02:40:00 5.8 2 12.2 1.9 5.8 1.9 12.6 1.9 5 2.2 10.7 1.1 318 19 334 165 -3 0.1 -2.6 -3.3 11/18/2006 02:50:00 9.2 1.8 14.9 5.3 9.1 1.9 15.6 5.3 8.5 1.8 14.9 4.9 331 12 333 165 -3.4 0.1 -2.8 -3.5 11/18/2006 03:00:00 7.8 2 12.6 3 7.6 1.9 13 2.6 7 1.8 11.1 2.6 329 14 10 165 -3.5 0 -3 -3.5 11/18/2006 03:10:00 9.7 1.8 15.3 5.3 9.5 1.9 14.1 5.3 8.8 1.7 13 4.6 333 11 332 165 -3.5 0.1 -3.3 -3.9 11/18/2006 03:20:00 8 2.2 13 2.3 7.7 2.2 13.3 2.3 6.8 2 11.5 2.3 338 15 338 165 -3.7 0 -3.3 -3.9 11/18/2006 03:30:00 8.3 1.9 12.6 3.8 8 2 12.6 3 7.1 2 12.2 2.6 338 13 341 165 -3.8 0 -3.5 -3.9 11/18/2006 03:40:00 9.2 2.3 15.3 3.8 9 2.4 15.3 3.4 8.3 2.2 15.3 3 334 13 332 165 -3.6 0 -3.5 -3.7 11/18/2006 03:50:00 10.2 1.9 14.5 5.7 10.1 2 14.9 5.7 9.3 2.2 14.9 3 334 12 344 165 -3.6 0 -3.3 -3.9 11/18/2006 04:00:00 10.6 2.4 17.9 5.3 10.4 2.5 18.3 5.3 9.4 2.4 15.6 4.6 336 13 319 165 -3.8 0 -3.5 -3.9 11/18/2006 04:10:00 9.9 2.6 16.4 3 9.7 2.6 16.1 3.4 9 2.5 14.9 3.4 331 12 339 165 -3.7 0 -3.3 -3.9 11/18/2006 04:20:00 9 2.2 15.3 3.4 8.8 2.2 15.3 3.8 7.8 2.2 14.5 2.6 331 13 330 165 -3.8 0 -3.3 -3.9 11/18/2006 04:30:00 8.7 2.6 14.5 2.6 8.6 2.6 14.9 2.6 7.6 2.8 13.7 1.5 335 17 347 165 -3.9 0 -3.5 -4.2 11/18/2006 04:40:00 10.4 2.3 16.4 3.4 10.3 2.3 16.1 3.8 9.5 2.3 15.3 4.2 329 11 344 165 -4 0 -3.5 -4.2 11/18/2006 04:50:00 6.4 2.9 14.9 1.1 6.3 2.8 15.3 1.1 5.6 2.8 14.5 1.5 321 29 341 165 -3.9 0 -3.5 -4.2 11/18/2006 05:00:00 7 1.9 12.6 3.4 7 1.8 12.6 2.6 6.1 1.7 11.5 2.6 313 22 328 165 -3.7 0.1 -3.3 -4.2 11/18/2006 05:10:00 7.5 1.4 11.1 4.2 8.1 1.6 11.8 4.6 7.5 1.8 11.1 3 283 17 276 165 -4.3 0 -3.5 -4.6 11/18/2006 05:20:00 8.7 1.4 12.2 4.9 9.3 1.5 12.6 4.9 8.4 1.7 13 4.6 279 11 271 165 -4.4 0.1 -3.9 -4.6 11/18/2006 05:30:00 10.3 1.2 13 7.2 10.4 1.2 13 7.2 9.5 1.4 13.3 6.1 285 11 285 165 -4.3 0.1 -3.9 -4.6 11/18/2006 05:40:00 8.6 1.7 13 4.2 8.8 1.6 13 3.8 8 1.7 11.8 3.4 287 15 287 165 -4.3 0.2 -3.9 -4.6 11/18/2006 05:50:00 9.8 1 12.2 5.7 9.9 1 12.6 6.1 8.6 1.4 11.5 4.9 289 9 291 165 -4.2 0.1 -3.9 -4.6 11/18/2006 06:00:00 9.1 1.7 13.3 4.6 9.3 1.7 13.3 4.9 8.5 2 12.6 3.8 285 11 284 165 -4.2 0.1 -3.7 -4.6 11/18/2006 06:10:00 10.4 1.4 14.9 5.7 10.4 1.4 15.3 5.7 9.3 1.8 15.3 4.6 287 10 289 165 -4 0.2 -3.5 -4.4 11/18/2006 06:20:00 9.6 1.5 14.1 5.7 9.5 1.5 13.7 6.1 8.1 1.7 13.3 4.9 299 14 331 165 -3.9 0.1 -3.5 -4.4 11/18/2006 06:30:00 10.6 1.3 14.5 6.8 10.6 1.3 14.5 7.2 8.8 1.5 13 5.3 291 10 296 165 -3.9 0.2 -3.5 -4.4 11/18/2006 06:40:00 10.7 1.7 16.1 6.5 10.7 1.7 16.1 6.8 9.4 1.8 14.1 4.9 297 14 287 165 -4.2 0.1 -3.7 -4.4 11/18/2006 06:50:00 9 1.5 13 5.3 8.9 1.5 13.7 5.3 8.5 1.5 12.6 4.9 324 16 348 165 -4.2 0 -3.9 -4.4 11/18/2006 07:00:00 7.8 1.8 13.7 3.8 7.6 1.6 12.2 4.2 7.6 1.8 13.3 3.8 334 13 350 165 -3.9 0 -3.5 -4.2 11/18/2006 07:10:00 8.1 1.6 12.6 4.6 8.1 1.6 11.8 4.2 7.4 1.6 11.1 3.8 314 20 312 165 -3.9 0 -3.5 -3.9 11/18/2006 07:20:00 8.2 1.2 11.8 5.7 8.2 1.2 11.8 5.3 7 1.1 10.3 4.6 305 17 298 165 -3.9 0 -3.5 -4.2 11/18/2006 07:30:00 8.2 1.5 11.5 4.6 8.1 1.5 11.5 4.6 7.7 1.2 11.1 4.6 323 17 317 165 -4.2 0 -3.7 -4.4 11/18/2006 07:40:00 9.3 2 14.5 5.3 9.2 2 13.7 5.3 9.2 2 14.5 4.9 336 11 350 165 -4.1 0 -3.9 -4.4 11/18/2006 07:50:00 11.3 1.7 16.1 7.2 11.2 1.7 16.1 7.2 11 1.8 15.3 7.2 329 11 328 165 -3.8 0 -3.5 -3.9 11/18/2006 08:00:00 10.8 2.1 15.6 6.1 10.7 2 15.6 6.1 10.2 2.3 16.4 5.7 326 11 322 165 -3.9 0 -3.5 -4.2 11/18/2006 08:10:00 11 1.5 14.9 7.6 10.9 1.5 14.9 7.2 10.6 1.7 15.3 5.7 332 11 325 165 -3.9 0 -3.5 -4.2 11/18/2006 08:20:00 9.8 2.2 16.4 3.4 9.6 2.2 16.1 3 9.4 2.2 16.1 3.8 331 12 339 165 -4 0.1 -3.5 -4.2 11/18/2006 08:30:00 11.5 2.5 17.9 3.8 11.4 2.5 17.6 4.6 10.7 2.3 17.2 5.3 330 13 327 165 -4.1 0 -3.5 -4.4 11/18/2006 08:40:00 13.1 2.3 18.7 8.4 12.8 2.3 17.9 8.4 12.1 2.2 18.3 7.2 334 10 337 165 -4.2 0 -3.9 -4.4 11/18/2006 08:50:00 12.4 2.1 17.6 7.2 12.2 2.3 17.6 6.8 11.4 2.2 15.6 5.7 338 10 332 165 -4.3 0 -3.9 -4.6 11/18/2006 09:00:00 12.5 2.1 16.8 7.6 12.3 2.3 17.9 7.2 11.7 2.1 17.6 6.1 339 10 340 165 -4.3 0 -3.9 -4.4 11/18/2006 09:10:00 12.9 1.5 16.1 8.8 12.7 1.8 16.1 7.6 12.3 1.6 16.1 7.6 338 10 334 165 -4.4 0 -3.9 -4.6 11/18/2006 09:20:00 13.2 1.7 17.6 8.4 12.8 1.9 17.2 7.2 12.5 1.8 16.8 8 334 10 325 165 -4.3 0 -4.2 -4.6 11/18/2006 09:30:00 13.3 2 17.2 8 13.1 1.9 17.2 7.6 12.6 2 17.2 8 334 10 328 165 -4.3 0 -3.9 -4.6 11/18/2006 09:40:00 14.4 2.3 19.1 9.1 14.2 2.3 19.5 8 13.4 2.4 19.1 7.6 335 10 327 165 -4.4 0 -4.2 -4.6 11/18/2006 09:50:00 13 2.2 17.6 7.6 12.8 2.4 17.9 5.7 11.8 2.4 15.6 4.9 341 9 346 165 -4.3 0.1 -3.9 -4.6 11/18/2006 10:00:00 14.1 1.6 17.9 9.5 13.7 1.9 18.7 7.6 12.9 1.8 17.2 8.4 338 10 344 165 -3.7 0.1 -3.3 -3.9 11/18/2006 10:10:00 11.6 1.8 17.6 7.2 11.3 1.9 17.9 7.2 10.4 1.8 16.4 6.5 339 10 344 165 -3.3 0 -3 -3.5 11/18/2006 10:20:00 12.8 1.9 19.5 7.6 12.4 2.2 19.1 6.8 11.6 1.9 17.6 7.2 342 10 335 165 -3.2 0 -2.8 -3.3 11/18/2006 10:30:00 12.6 1.9 17.2 6.5 11.9 2.1 17.2 6.1 11.6 1.7 16.1 6.8 343 10 350 165 -3.1 0 -2.8 -3.3 11/18/2006 10:40:00 10.6 1.7 14.9 6.5 10 1.8 14.9 6.5 9.7 1.9 14.1 2.6 343 10 355 165 -2.9 0 -2.6 -3 11/18/2006 10:50:00 9.6 1.8 13.7 5.3 8.1 2.2 14.1 3.8 8.7 1.9 13.3 3 355 13 356 165 -2.9 0.1 -2.6 -3.3 11/18/2006 11:00:00 10.2 1.9 15.6 5.7 9.4 2 15.3 5.3 9.5 1.8 15.6 6.1 346 9 353 165 -2.8 0.1 -2.4 -3 11/18/2006 11:10:00 13.1 2 17.9 8.8 12.8 2.4 17.9 6.5 12.4 2.1 18.7 8 341 10 338 165 -2.8 0.2 -2.4 -3 11/18/2006 11:20:00 14.1 1.7 19.1 10.3 13.2 2.4 17.6 6.8 13.3 1.8 17.6 8 347 8 357 165 -3.2 0.1 -2.6 -3.5 11/18/2006 11:30:00 14 1.7 17.9 9.9 13.2 2.3 18.3 7.2 13.2 1.9 17.9 8.8 345 9 349 165 -3.2 0 -2.8 -3.5 11/18/2006 11:40:00 13.9 1.7 18.3 9.1 12.8 2.7 18.3 6.8 13.2 2.1 18.7 8 346 11 338 165 -3.5 0.1 -2.8 -3.7 11/18/2006 11:50:00 13.1 1.3 17.2 9.9 12.2 2.2 17.9 6.1 12.3 1.5 15.6 8.4 347 9 344 165 -3.5 0.1 -3 -3.7 11/18/2006 12:00:00 12.7 1.8 17.2 8.8 12.4 1.9 17.2 7.2 11.8 2 16.8 7.2 340 9 332 165 -3.4 0 -3 -3.5 11/18/2006 12:10:00 12.4 1.9 16.8 7.6 12.2 2 16.8 7.6 11.5 2.1 17.2 7.2 338 9 343 165 -3.2 0.1 -2.8 -3.5 11/18/2006 12:20:00 13.6 2.6 19.1 8 13.4 2.7 19.1 7.6 12.6 2.5 18.3 6.5 338 9 332 165 -3.1 0 -2.8 -3.3 11/18/2006 12:30:00 13.3 1.6 17.2 9.1 13.1 1.7 17.2 8.8 12.1 1.9 17.2 6.8 338 9 332 165 -2.8 0.2 -2.6 -3 11/18/2006 12:40:00 13.1 2.1 19.1 8.4 13 2.2 19.5 7.6 12.4 2.1 17.2 7.2 337 9 343 165 -3.1 0.2 -2.6 -3.5 11/18/2006 12:50:00 14.2 2.1 20.2 9.1 14 2.3 21 8.4 13.2 2 20.2 8.8 339 9 346 165 -3.2 0 -3 -3.5 11/18/2006 13:00:00 12.8 3.3 19.1 5.7 12.7 3.3 19.1 6.1 12.3 3.6 19.1 5.3 331 15 345 165 -3.1 0.1 -2.8 -3.5 11/18/2006 13:10:00 12.3 2.3 20.6 6.8 12.1 2.3 20.6 6.8 11.7 2.2 19.1 6.8 332 11 347 165 -3 0 -2.6 -3.5 11/18/2006 13:20:00 11.6 1.8 16.4 7.2 11.3 1.8 16.1 6.1 11.4 1.9 16.8 7.6 339 11 356 165 -2.9 0 -2.6 -3.5 11/18/2006 13:30:00 9.6 2.3 15.6 4.9 9.3 2.3 15.6 4.9 9 2.4 14.5 2.3 334 16 338 165 -2.6 0.2 -2.1 -3.3 11/18/2006 13:40:00 8.9 2 14.1 3.4 8.8 2 13.7 3.4 8.4 2.3 14.9 3.8 325 13 326 165 -2.6 0.1 -2.1 -3 11/18/2006 13:50:00 7.5 1.5 12.6 4.2 7.4 1.5 12.6 4.2 7.1 1.5 12.6 4.2 319 15 327 165 -2.5 0 -2.1 -2.8 11/18/2006 14:00:00 8.4 2 14.5 3.4 8.2 1.9 13.7 3.4 7.9 1.9 14.1 4.6 318 20 351 165 -2.7 0.2 -2.1 -3.3 11/18/2006 14:10:00 8.5 3.3 16.8 3 8 2.8 15.6 2.3 8.1 3.2 15.6 2.3 326 22 356 165 -2.5 0.1 -2.1 -3 11/18/2006 14:20:00 10.2 2.1 17.6 5.3 10 2.1 17.2 5.7 9.9 2.1 15.6 5.3 336 12 338 165 -2.5 0.1 -2.1 -2.8 11/18/2006 14:30:00 7.1 1.7 10.7 3.4 7 1.7 11.5 2.6 6.4 1.7 11.5 3 306 21 312 165 -2.6 0.1 -2.1 -3 11/18/2006 14:40:00 8.1 1.7 12.2 3.8 8.1 1.7 11.8 4.2 7.2 1.6 12.2 3 294 18 277 165 -2.6 0.1 -2.1 -3 11/18/2006 14:50:00 8.5 1.7 13.3 4.9 8.5 1.7 13.3 4.6 7.9 1.7 13.3 3.8 302 19 307 165 -3.2 0.3 -2.4 -3.9 11/18/2006 15:00:00 7.4 2.2 13 3 7.3 2.2 12.6 2.6 6.6 2.2 13 2.3 308 22 291 165 -3.4 0 -2.8 -3.5 11/18/2006 15:10:00 6.4 1.2 9.9 3 6.5 1.2 10.3 3.4 5.7 1.3 10.3 2.6 297 17 299 165 -2.9 0.2 -2.6 -3.5 11/18/2006 15:20:00 8.8 1.6 14.1 4.6 8.8 1.6 14.1 4.9 7.6 1.7 13.3 3.8 299 14 280 165 -3.2 0 -2.8 -3.5 11/18/2006 15:30:00 9.3 1.5 13.3 4.9 9.2 1.5 13.3 4.6 7.9 1.6 12.2 4.2 297 14 312 165 -3.5 0.1 -3 -3.9 11/18/2006 15:40:00 10.8 1.6 14.5 6.5 10.7 1.6 14.5 6.5 8.6 1.6 13 4.9 298 8 291 165 -4 0.1 -3.5 -4.4 11/18/2006 15:50:00 11.6 2.1 17.9 4.6 11.5 2 17.6 4.6 9.6 2 15.6 3.8 297 12 298 165 -4.1 0 -3.7 -4.4 11/18/2006 16:00:00 12.8 2.3 18.3 5.3 12.7 2.3 17.9 5.7 10.7 2 15.6 4.6 293 9 297 165 -3.9 0 -3.5 -4.2 11/18/2006 16:10:00 13.2 2.3 19.9 6.8 13.1 2.3 19.5 7.2 10.8 2.3 18.7 4.9 293 9 286 165 -3.9 0 -3.5 -4.4 11/18/2006 16:20:00 13.4 1.6 17.6 8.4 13.2 1.5 17.2 8.8 10.7 1.8 15.3 6.8 290 8 284 165 -4.2 0 -3.7 -4.4 11/18/2006 16:30:00 9.6 1.8 13.7 3.8 9.5 1.7 13.7 3 7.3 1.9 12.2 3 293 13 311 165 -4.3 0.2 -3.9 -4.6 11/18/2006 16:40:00 7.5 2.2 12.6 3 7.5 2.2 13 3 5.5 2 10.7 1.1 300 22 297 165 -4.5 0 -4.4 -4.6 11/18/2006 16:50:00 6.1 2.1 11.5 1.9 6 2.1 11.5 1.9 5 1.8 11.1 1.5 313 22 333 165 -4.5 0 -4.2 -4.6 11/18/2006 17:00:00 6.3 1.8 12.6 2.6 6.2 1.7 12.2 2.3 5.1 1.5 9.9 1.1 310 26 287 165 -4.2 0.1 -3.9 -4.6 11/18/2006 17:10:00 6.4 2.7 12.2 0.4 6.5 2.6 12.6 0.7 5 2 11.1 0.4 290 36 285 165 -4.4 0 -3.9 -4.6 11/18/2006 17:20:00 7 2.1 11.8 1.9 7 2 12.6 1.5 5.3 1.7 10.3 1.1 306 23 320 165 -4.5 0 -4.4 -4.6 11/18/2006 17:30:00 6.9 2.3 12.6 1.5 6.8 2.3 11.8 1.5 5 2.1 11.1 0.7 309 24 314 165 -4.6 0 -4.2 -4.6 11/18/2006 17:40:00 5.1 1.7 10.3 1.1 5.1 1.7 10.3 0.7 4.2 1.7 9.5 0.7 324 49 329 165 -4.4 0 -4.2 -4.6 11/18/2006 17:50:00 8 2.8 14.9 0.7 7.7 2.7 15.3 1.1 6.6 2.8 13 0.7 331 20 353 165 -4.2 0.1 -3.9 -4.4 11/18/2006 18:00:00 8.9 2.8 15.3 2.3 8.6 2.8 15.6 2.6 7.7 2.8 14.5 2.3 327 22 309 165 -4.1 0.2 -3.5 -4.6 11/18/2006 18:10:00 10.6 2.1 17.2 5.7 10.3 2 16.8 4.6 9.8 1.8 15.3 4.9 330 15 333 165 -3.7 0 -3.5 -3.9 11/18/2006 18:20:00 11.7 2.9 17.6 5.3 11.3 2.9 18.3 4.6 10 3.3 17.6 0.4 334 17 341 165 -3.8 0.3 -3.3 -4.2 11/18/2006 18:30:00 14.2 2.8 22.6 5.3 13.6 2.9 21.4 5.7 12.3 3.3 19.5 2.6 340 12 338 165 -3.3 0 -3 -3.5 11/18/2006 18:40:00 14.9 2 19.9 8.8 14.5 2.3 20.6 7.2 13.3 2.6 20.2 6.8 342 10 331 165 -3 0 -2.8 -3.3 11/18/2006 18:50:00 11.8 2.5 19.9 7.2 11.4 2.3 20.2 6.5 10.4 2.2 16.1 4.9 335 13 338 165 -2.9 0 -2.8 -3.3 11/18/2006 19:00:00 8.1 1.7 13 4.2 8 1.7 13 3.4 6.7 1.6 11.1 2.6 316 20 300 165 -3.7 0.3 -2.8 -4.4 11/18/2006 19:10:00 8.4 2.4 13 2.3 8.3 2.4 13 1.9 6.2 2.1 12.2 1.1 303 19 304 165 -4.5 0.1 -3.9 -4.6 11/18/2006 19:20:00 9.8 1.8 15.3 3.8 9.7 1.7 14.9 4.2 7.1 1.9 11.5 3 298 13 282 165 -4.7 0 -4.4 -4.6 11/18/2006 19:30:00 9.9 1.9 14.5 3.8 9.7 1.9 14.1 3.4 7.9 1.9 13.7 3 304 12 300 165 -4.6 0 -4.4 -4.6 11/18/2006 19:40:00 9.8 2.1 14.1 3.4 9.7 2 14.1 2.6 7.5 1.9 11.5 2.3 297 13 291 165 -4.5 0 -4.4 -4.6 11/18/2006 19:50:00 8.4 2.2 13.3 4.2 8.3 2.1 13 3.8 6.1 1.8 10.3 1.5 297 18 309 165 -4.5 0 -4.4 -4.6 11/18/2006 20:00:00 11 2.5 16.8 4.2 10.8 2.5 16.4 4.6 8.4 2.3 13.7 3 296 12 298 165 -4.5 0 -4.2 -4.6 11/18/2006 20:10:00 13 2.5 19.1 7.2 12.8 2.4 19.5 6.1 10.2 2 16.4 5.3 299 9 314 165 -4.3 0 -3.9 -4.6 11/18/2006 20:20:00 13.8 1.8 18.7 9.1 13.6 1.7 17.9 8.8 11 1.7 15.6 6.5 296 9 290 165 -4.2 0 -3.9 -4.4 11/18/2006 20:30:00 14.6 1.7 18.3 10.7 14.4 1.7 18.3 10.3 11.6 1.9 16.8 5.3 301 9 292 165 -4 0 -3.7 -4.4 11/18/2006 20:40:00 15.4 2.2 20.2 9.1 15.2 2.2 19.5 8.4 12.3 1.8 17.2 7.2 299 10 300 165 -4 0 -3.9 -4.2 11/18/2006 20:50:00 17.2 2.1 22.1 12.2 16.9 2 21.8 12.2 13.5 2 18.7 8 301 7 301 165 -3.9 0 -3.5 -4.2 11/18/2006 21:00:00 13.4 2.1 19.1 8.4 13.2 2 18.3 8.4 11.2 2 17.2 6.1 307 9 301 165 -4.1 0.1 -3.5 -4.4 11/18/2006 21:10:00 13.3 2.3 18.3 8 13.2 2.2 18.3 7.6 11 2.4 17.6 4.2 308 11 311 165 -4 0 -3.7 -4.2 11/18/2006 21:20:00 11.9 1.7 16.4 6.1 11.8 1.7 16.1 6.5 9.9 2 16.1 4.2 312 11 315 165 -4.1 0.1 -3.7 -4.4 11/18/2006 21:30:00 11.8 1.7 15.6 7.2 11.7 1.7 15.3 7.6 10.5 2.3 16.1 5.7 316 10 319 165 -4 0 -3.7 -4.4 11/18/2006 21:40:00 12.6 2.2 17.6 6.8 12.4 2.1 17.2 6.5 11.6 2 17.6 6.5 319 9 310 165 -3.7 0.1 -3.3 -3.9 11/18/2006 21:50:00 13 2 17.6 8.4 12.8 2 17.6 8.4 11.8 1.8 17.6 7.6 314 11 305 165 -3.5 0 -3.3 -3.7 11/18/2006 22:00:00 13.2 1.8 20.2 9.5 13 1.8 20.2 9.1 12.3 1.8 18.7 8 316 9 319 165 -3.5 0.1 -3.3 -3.5 11/18/2006 22:10:00 12.5 1.5 17.2 8.4 12.3 1.5 16.8 8.4 11.5 1.6 16.4 7.2 315 11 307 165 -3.7 0 -3.3 -3.9 11/18/2006 22:20:00 13.2 2 19.1 8.4 13 2.1 19.1 8 12.4 2.2 19.5 7.2 325 17 339 165 -3.5 0.1 -3 -3.9 11/18/2006 22:30:00 15.4 2.5 22.9 9.9 15.3 2.6 23.3 10.3 15 2.7 22.6 9.1 331 11 350 165 -3.2 0.1 -2.8 -3.5 11/18/2006 22:40:00 15.5 2.3 21.8 9.9 15.3 2.4 21.8 9.1 14.9 2.6 21 8.8 325 17 329 165 -3.1 0 -2.8 -3.5 11/18/2006 22:50:00 14 2.4 21.4 9.1 13.8 2.4 21.4 8.8 13 2.4 21.4 8.4 319 11 319 165 -3.4 0 -3 -3.5 11/18/2006 23:00:00 13.3 1.5 17.6 8.8 13.2 1.5 17.2 9.1 11.8 1.5 16.4 7.6 312 9 314 165 -3.5 0 -3 -3.7 11/18/2006 23:10:00 13.7 1.6 17.2 8.8 13.6 1.6 16.8 8.8 11.4 2.2 16.4 4.6 310 9 305 165 -3.7 0 -3.3 -3.9 11/18/2006 23:20:00 13.4 2.1 18.7 7.2 13.3 2 18.3 6.1 10 2.5 16.1 3 300 10 302 165 -3.9 0 -3.5 -3.9 11/18/2006 23:30:00 12.7 2.1 17.6 6.1 12.7 2.1 17.2 5.7 9.4 2.6 15.3 1.9 302 12 295 165 -3.9 0 -3.5 -3.9 11/18/2006 23:40:00 13.5 2.1 18.7 7.2 13.4 2 18.3 6.8 10.4 2.2 17.2 4.6 302 11 302 165 -3.9 0 -3.5 -3.9 11/18/2006 23:50:00 12.9 2.5 18.7 5.7 12.8 2.5 19.1 6.1 9.8 2.6 16.1 3 300 16 299 165 -3.8 0 -3.5 -3.9 11/19/2006 00:00:00 11.7 2.2 16.4 3.4 11.7 2.2 16.4 5.3 8.8 2.6 15.3 1.1 299 15 295 165 -3.7 0 -3.5 -3.9 11/19/2006 00:10:00 10.7 2.3 16.8 4.2 10.7 2.3 16.8 4.6 8 2.5 15.6 1.9 307 20 300 165 -3.7 0 -3.5 -3.9 11/19/2006 00:20:00 12.7 2.3 17.9 7.2 12.5 2.3 17.9 6.1 11.4 2.2 15.6 5.3 324 15 296 165 -3.7 0 -3.5 -3.9 11/19/2006 00:30:00 16.7 1.7 22.1 12.6 16.4 1.6 22.1 12.6 14.7 1.5 19.1 10.3 311 8 310 165 -3.7 0 -3.3 -3.9 11/19/2006 00:40:00 17.1 1.7 21 11.5 16.8 1.7 20.6 11.1 15.1 1.9 19.9 8.8 310 6 314 165 -3.8 0 -3.5 -3.9 11/19/2006 00:50:00 13.9 1.7 17.6 8.4 13.8 1.7 17.6 8.4 11.9 1.9 16.1 6.5 310 12 300 165 -4.2 0.1 -3.5 -4.4 11/19/2006 01:00:00 12.4 2 17.6 7.2 12.2 1.9 17.9 7.2 11.2 2.1 17.6 6.8 325 15 346 165 -4.2 0 -3.9 -4.4 11/19/2006 01:10:00 12.9 1.3 16.4 8.8 12.6 1.4 16.8 8.8 11.5 1.1 14.1 8 315 12 322 165 -4.2 0.1 -3.9 -4.4 11/19/2006 01:20:00 14.1 1.6 19.9 10.7 13.9 1.5 20.2 10.3 12.7 1.7 17.2 8 312 8 300 165 -4.3 0 -3.9 -4.6 11/19/2006 01:30:00 18 1.6 22.9 14.5 17.8 1.6 22.9 14.1 17.1 1.9 22.6 11.8 314 7 313 165 -4 0.1 -3.7 -4.4 11/19/2006 01:40:00 19.9 1.5 24 16.1 19.6 1.5 24 15.6 18.7 1.7 24 13.7 314 6 313 165 -4.4 0 -4.2 -4.6 11/19/2006 01:50:00 19.1 1.7 24.4 14.5 18.9 1.8 23.7 14.5 18.2 2.1 23.3 11.5 315 9 307 165 -4.4 0 -4.2 -4.6 11/19/2006 02:00:00 18.1 1.7 22.9 12.6 17.8 1.7 22.9 13 17.1 1.8 21.8 10.7 316 7 330 165 -4.2 0.1 -3.7 -4.4 11/19/2006 02:10:00 20.1 1.8 25.2 11.8 19.8 1.8 25.2 11.8 19.1 2.1 24.8 10.7 317 6 315 165 -4 0 -3.5 -4.4 11/19/2006 02:20:00 19.6 1.7 25.2 15.3 19.3 1.7 24.8 15.6 18.8 2.1 25.2 13 316 6 316 165 -4.1 0.2 -3.5 -4.6 11/19/2006 02:30:00 17.3 1.7 23.7 11.8 17.1 1.7 22.6 11.8 15.9 1.9 21.4 9.1 312 9 302 165 -4.3 0 -3.9 -4.6 11/19/2006 02:40:00 17.6 1.5 23.7 14.5 17.4 1.5 23.7 14.1 16 1.8 21.4 10.7 311 8 300 165 -4.3 0 -3.9 -4.6 11/19/2006 02:50:00 17.5 1.6 21 13.3 17.3 1.6 21 13.3 15.6 1.9 20.6 10.7 308 9 311 165 -4.5 0.1 -3.9 -4.8 11/19/2006 03:00:00 17.4 1.8 21.8 13.7 17.3 1.7 21.4 13.3 14.7 2.1 20.2 9.5 305 8 301 165 -4.8 0.1 -4.4 -5.3 11/19/2006 03:10:00 18.1 1.7 22.1 13 18 1.7 21.8 12.6 15.4 1.9 21.8 10.7 306 7 300 165 -5 0 -4.6 -5.3 11/19/2006 03:20:00 18.3 1.6 22.9 13.7 18.1 1.6 22.1 13.3 16.4 1.8 21.4 12.6 308 8 313 165 -5.2 0.1 -4.6 -5.5 11/19/2006 03:30:00 18.5 1.5 22.9 13.3 18.3 1.5 22.9 14.5 16.2 1.9 21.4 10.7 309 8 310 165 -5.2 0 -4.8 -5.5 11/19/2006 03:40:00 18.4 1.5 22.1 13 18.3 1.5 21.8 13.3 16.9 1.7 21.8 10.7 310 7 312 165 -5.3 0.1 -4.8 -5.5 11/19/2006 03:50:00 19.7 1.7 25.2 15.3 19.6 1.6 24.8 14.9 16.6 2.1 21.8 10.7 305 7 302 165 -5.3 0.1 -5 -5.5 11/19/2006 04:00:00 19 1.8 23.3 13.3 18.8 1.8 22.6 14.1 15.9 2.5 22.6 10.7 303 11 281 165 -5.1 0.1 -4.6 -5.5 11/19/2006 04:10:00 18.1 2.1 22.9 8.8 17.9 2.1 22.9 8.8 15.1 2.4 22.1 9.1 304 10 287 165 -5 0.1 -4.6 -5.3 11/19/2006 04:20:00 16.3 2.3 23.3 9.9 16.2 2.4 23.3 10.3 15.8 2.5 22.9 10.3 330 12 341 165 -4.9 0.2 -4.4 -5.3 11/19/2006 04:30:00 17 2.4 22.9 11.8 16.8 2.5 23.3 11.1 16.5 2.7 23.3 10.7 331 12 339 165 -4.4 0.1 -3.9 -4.8 11/19/2006 04:40:00 13.6 2 17.9 8 13.1 2 17.9 8.4 12.7 2 16.8 8 331 15 337 165 -4.7 0.1 -4.4 -5 11/19/2006 04:50:00 10.4 2.2 14.9 4.2 10.3 2.1 15.3 4.9 8.9 2.1 14.1 3.4 311 13 315 165 -5.4 0.3 -4.2 -5.7 11/19/2006 05:00:00 10.5 2.5 15.3 4.2 10.3 2.5 15.6 3.4 9 2.6 14.1 3 314 16 299 165 -5.6 0.1 -5.3 -5.7 11/19/2006 05:10:00 15.8 2.7 22.9 9.9 15.2 2.8 23.3 9.9 15 3.1 24 8.4 332 17 338 165 -5.1 0.3 -4.6 -5.7 11/19/2006 05:20:00 13.8 2.2 19.5 7.6 13.6 2.2 19.1 7.2 13.2 2.1 19.5 8 322 11 325 165 -5.7 0.1 -5.3 -5.9 11/19/2006 05:30:00 11.7 1.7 15.6 6.5 11.3 1.9 15.6 6.1 11.3 1.7 16.4 7.2 336 15 325 165 -5.3 0.1 -5 -5.7 11/19/2006 05:40:00 11.6 2 17.6 6.1 11.4 2 17.2 6.1 10.5 1.8 16.4 5.3 310 22 307 165 -5.4 0.2 -5 -5.7 11/19/2006 05:50:00 14.7 2 20.2 8.8 14.5 1.9 19.9 9.5 13.3 2.6 19.9 8 313 15 301 165 -5.6 0.2 -5.3 -5.9 11/19/2006 06:00:00 17.1 2.5 23.7 9.5 16.9 2.5 23.3 9.9 16.3 2.5 22.9 10.3 319 12 273 165 -5.6 0.1 -5.3 -5.9 11/19/2006 06:10:00 18.2 2 23.7 13 18 2 24 13 17.7 2.1 25.2 12.6 325 12 307 165 -5.6 0 -5.3 -5.7 11/19/2006 06:20:00 17.6 1.9 22.9 12.2 17.3 2.1 22.9 9.5 16.9 2 22.1 11.1 329 14 315 165 -5.7 0 -5.5 -5.9 11/19/2006 06:30:00 16.9 1.9 21.8 12.2 16.4 2.1 21.8 10.7 16.2 2.2 20.6 10.3 327 15 306 165 -5.8 0.1 -5.5 -6.1 11/19/2006 06:40:00 18.1 2.2 26 13.3 17.9 2.3 26.3 13 17.5 2.2 24.8 12.6 322 13 303 165 -6 0 -5.7 -6.4 11/19/2006 06:50:00 18.8 2.2 23.7 13.3 18.6 2.2 23.3 13 17.9 2.3 26 12.2 316 10 303 165 -6.1 0 -5.7 -6.4 11/19/2006 07:00:00 20.1 1.5 24.4 15.6 19.8 1.5 24 15.3 17.8 1.7 22.1 12.6 308 7 306 165 -6.3 0.1 -5.9 -6.6 11/19/2006 07:10:00 21.1 1.9 27.1 14.9 20.9 1.9 26.3 14.9 18.3 2.2 25.2 12.2 305 9 298 165 -6.2 0.1 -5.7 -6.6 11/19/2006 07:20:00 24 2 31.3 18.7 23.8 2 30.9 18.3 20.9 2.7 28.3 14.1 304 8 303 165 -5.9 0.1 -5.5 -6.4 11/19/2006 07:30:00 23.2 1.9 27.1 18.3 23.1 2 27.1 17.9 19.7 2.3 27.1 13.7 302 9 297 165 -6.2 0.1 -5.9 -6.6 11/19/2006 07:40:00 23.4 2.3 30.2 17.6 23.3 2.3 29.8 17.6 19.7 2.6 26.3 13.7 300 9 297 165 -6 0.2 -5.5 -6.6 11/19/2006 07:50:00 22.9 3.2 30.9 15.3 22.8 3.2 30.9 15.3 19.8 3.2 32.1 13 303 10 305 165 -5.4 0.2 -4.8 -5.7 11/19/2006 08:00:00 20.4 2.7 29.1 13 20.2 2.7 28.7 12.2 17.8 2.8 27.1 9.1 304 11 319 165 -4.9 0.2 -4.4 -5.3 11/19/2006 08:10:00 22 2.9 29.8 14.5 21.8 2.9 29.4 13.7 19 3.2 29.4 13 303 11 315 165 -4.9 0.2 -4.4 -5.5 11/19/2006 08:20:00 21.8 2.6 28.3 15.6 21.7 2.6 28.3 15.6 18.8 3.1 26.3 11.5 304 11 297 165 -4.8 0.1 -4.4 -5.3 11/19/2006 08:30:00 22 2.4 30.2 12.6 21.8 2.4 29.1 11.8 18.9 2.7 30.9 9.9 303 10 307 165 -5.2 0.3 -4.4 -5.7 11/19/2006 08:40:00 23.7 2.5 29.8 16.8 23.6 2.5 29.1 16.8 20.8 2.7 29.4 13.7 303 10 275 165 -5.5 0.3 -5 -6.1 11/19/2006 08:50:00 24.9 2.4 32.4 18.7 24.9 2.5 31.8 17.9 22.6 2.7 32.4 14.9 305 8 283 165 -6 0.2 -5.5 -6.6 11/19/2006 09:00:00 24.8 2.2 31.8 18.7 24.7 2.2 31.8 18.3 22.5 2.3 30.6 17.2 307 7 302 165 -6.4 0.1 -5.9 -6.6 11/19/2006 09:10:00 24.7 2.3 31.3 19.5 24.6 2.3 30.9 18.7 22.2 2.9 30.9 14.5 307 9 317 165 -6.4 0.1 -6.1 -6.6 11/19/2006 09:20:00 24.8 2.8 33.2 16.8 24.6 2.8 32.1 15.6 22.3 3.2 30.6 14.1 305 10 303 165 -6.2 0.2 -5.5 -6.6 11/19/2006 09:30:00 22.4 2.9 33.2 14.9 22.2 2.8 33.2 15.3 19.7 3.2 30.9 11.8 303 10 293 165 -5.3 0.2 -4.8 -5.7 11/19/2006 09:40:00 22.4 2.8 30.2 14.9 22.2 2.7 30.2 15.3 19.2 3.2 28.7 9.9 302 12 310 165 -5.3 0.2 -4.8 -5.7 11/19/2006 09:50:00 22.1 3.2 33.6 15.3 21.9 3.2 34.8 14.5 19.6 3.2 29.4 11.8 304 13 270 165 -5.4 0.2 -5 -5.7 11/19/2006 10:00:00 21.9 2.7 28.7 14.9 21.7 2.7 29.1 14.9 19.5 3.1 27.1 11.8 307 11 297 165 -5.5 0.2 -4.8 -6.1 11/19/2006 10:10:00 21.6 3.3 30.9 14.5 21.4 3.3 30.6 14.1 19.8 3.5 29.1 12.2 311 13 303 165 -5.4 0.1 -5 -5.9 11/19/2006 10:20:00 23.8 2.9 31.8 15.3 23.6 2.9 31.8 14.9 21.7 3.3 32.1 13.3 310 10 295 165 -5.5 0.2 -4.8 -5.9 11/19/2006 10:30:00 25.6 2.9 33.6 20.2 25.4 2.9 34.8 19.9 24.1 3.1 32.9 15.3 312 9 299 165 -5.6 0.2 -5.3 -6.1 11/19/2006 10:40:00 24.8 2.7 31.3 16.1 24.5 2.7 30.9 15.6 23.4 3.1 30.9 13.3 313 11 307 165 -5.6 0.1 -5.3 -5.9 11/19/2006 10:50:00 20.2 4.1 32.1 9.9 19.9 4.1 31.8 10.3 19 4 30.6 9.5 317 12 310 165 -5.6 0 -5.3 -5.7 11/19/2006 11:00:00 16.6 2.8 24.4 9.9 16.2 2.8 24 8.4 15.8 2.8 23.7 8.4 328 17 332 165 -5.4 0.1 -5.3 -5.7 11/19/2006 11:10:00 17.2 2.7 26 10.7 16.7 2.9 26.3 9.9 16.6 2.8 25.2 9.5 331 15 334 165 -5.2 0 -5 -5.5 11/19/2006 11:20:00 18.8 2.7 26.8 12.6 18.5 2.7 25.6 13 18.1 2.9 26 12.6 324 17 356 165 -5 0.1 -4.6 -5.5 11/19/2006 11:30:00 17.5 2.5 26.8 11.1 17.2 2.5 27.5 10.7 16.3 2.5 24 9.1 318 13 310 165 -5.2 0 -4.6 -5.5 11/19/2006 11:40:00 16.1 2.2 22.6 9.5 16 2.2 22.6 9.9 13.7 2.4 20.6 6.8 306 11 315 165 -4.8 0 -4.6 -5 11/19/2006 11:50:00 18.7 2.2 24.8 12.2 18.5 2.2 24.8 12.6 16.6 2.4 24 10.3 307 10 269 165 -5 0 -4.6 -5.3 11/19/2006 12:00:00 20.2 2.7 30.2 9.5 20 2.7 30.2 8.8 18.4 3.2 31.3 9.9 312 15 344 165 -4.9 0.1 -4.4 -5.3 11/19/2006 12:10:00 20.8 2.1 26.8 14.1 20.6 2.1 26.3 14.9 19.4 2.2 25.2 11.5 310 9 316 165 -4.9 0.1 -4.4 -5 11/19/2006 12:20:00 21.3 1.9 26.3 15.6 21.1 2 26 14.9 19.6 2.1 25.6 14.5 310 8 278 165 -4.9 0 -4.4 -5.3 11/19/2006 12:30:00 22 2 29.8 17.6 21.8 2 29.8 17.2 20.9 2.2 30.2 14.9 313 8 312 165 -4.9 0 -4.6 -5 11/19/2006 12:40:00 22.5 2.3 29.4 17.2 22.3 2.3 29.1 16.8 21.3 2.5 28.7 14.1 314 9 325 165 -4.8 0 -4.6 -5 11/19/2006 12:50:00 22.5 2.7 29.1 15.6 22.3 2.8 29.4 15.6 22 2.9 32.1 14.9 318 11 321 165 -4.6 0 -4.4 -4.6 11/19/2006 13:00:00 23 2.7 30.9 16.1 22.7 2.8 30.6 15.6 21.6 2.8 30.9 14.5 316 11 315 165 -4.6 0 -4.4 -4.6 11/19/2006 13:10:00 23.4 3.1 34 13.7 23.3 3.1 34 14.1 21.5 3.2 30.9 13.7 311 11 298 165 -4.4 0.1 -4.2 -4.6 11/19/2006 13:20:00 24.3 2.7 32.4 16.1 24.1 2.7 32.1 15.6 22.3 3.3 32.4 14.1 309 10 298 165 -4.5 0.1 -3.9 -4.8 11/19/2006 13:30:00 26.1 2.9 36.3 18.7 25.9 2.9 35.5 17.9 24.3 3.1 35.2 15.6 309 11 316 165 -4.7 0 -4.4 -4.8 11/19/2006 13:40:00 26.7 2.2 33.6 19.1 26.5 2.3 32.9 18.7 25.7 2.3 32.9 18.3 312 9 341 165 -4.8 0 -4.6 -5 11/19/2006 13:50:00 27.2 2.3 32.9 19.9 27 2.3 32.9 19.1 26.2 2.3 33.6 19.5 311 8 315 165 -4.9 0 -4.6 -5 11/19/2006 14:00:00 24.7 3.3 33.2 16.4 24.5 3.2 32.9 16.1 22.5 3.3 31.3 14.9 308 12 295 165 -4.4 0.1 -3.9 -4.6 11/19/2006 14:10:00 19.3 2.5 25.2 13 19.1 2.5 25.2 13.7 16.9 2.8 24.4 9.9 315 16 312 165 -3.9 0.1 -3.5 -4.2 11/19/2006 14:20:00 21.1 2.6 29.8 15.3 20.9 2.7 31.3 14.9 19.6 3.1 28.7 13.3 320 15 335 165 -3.6 0 -3.3 -3.7 11/19/2006 14:30:00 24.9 2.8 31.8 15.3 24.7 2.8 31.3 14.9 23.5 2.7 30.9 14.1 312 11 306 165 -3.8 0.1 -3.3 -4.2 11/19/2006 14:40:00 26 2.6 34 18.3 25.8 2.6 34 17.9 24.4 3.1 33.2 13.7 311 9 318 165 -3.9 0 -3.5 -3.9 11/19/2006 14:50:00 25 2.5 33.2 17.9 24.9 2.5 32.4 17.6 23.7 2.8 34 17.2 312 9 319 165 -3.8 0.1 -3.3 -4.2 11/19/2006 15:00:00 25.9 2.7 34.8 16.4 25.7 2.7 34.8 16.1 23.6 3.1 32.1 16.8 309 11 297 165 -3.7 0.2 -3 -3.9 11/19/2006 15:10:00 25.8 2.8 34.4 19.1 25.6 2.8 34.4 18.3 23.6 2.9 32.9 16.1 309 12 328 165 -3.6 0.1 -3.3 -3.9 11/19/2006 15:20:00 24.3 3.2 34.8 13 24.1 3.2 35.5 13 22.2 3.3 32.1 14.1 312 11 322 165 -3.3 0.3 -2.8 -3.9 11/19/2006 15:30:00 21.6 3.8 34.8 13 21.4 3.6 34.4 13 18.3 3.5 28.3 8.8 303 12 321 165 -2.8 0 -2.6 -3 11/19/2006 15:40:00 19.3 2.7 27.5 13.3 19.1 2.7 27.5 13.3 17.2 2.9 29.1 11.1 308 10 314 165 -2.9 0 -2.6 -3 11/19/2006 15:50:00 20.7 3.3 28.3 9.9 20.5 3.3 28.3 9.9 18.1 3.2 28.7 8.8 306 11 292 165 -3.3 0.3 -2.8 -3.7 11/19/2006 16:00:00 23.6 3.1 33.2 16.1 23.4 3.1 32.9 15.6 20.3 2.8 29.8 14.9 304 10 322 165 -3.8 0.3 -3.3 -4.4 11/19/2006 16:10:00 25.6 2.5 33.2 18.7 25.5 2.4 34 19.1 22.7 3.1 31.8 14.1 306 9 301 165 -4.2 0.2 -3.3 -4.6 11/19/2006 16:20:00 26.6 2.6 38.2 19.5 26.5 2.5 37.1 18.3 23.7 3.1 33.2 16.8 304 10 304 165 -4.2 0.3 -3.5 -4.6 11/19/2006 16:30:00 28 2.3 35.2 22.6 27.9 2.3 35.5 22.1 26.4 2.9 36.7 19.1 306 9 314 165 -4.8 0.3 -4.2 -5.5 11/19/2006 16:40:00 28 2.2 35.2 21.4 28 2.2 35.2 21.4 26.1 2.5 33.6 20.2 306 8 303 165 -4.9 0.1 -4.4 -5.3 11/19/2006 16:50:00 26.3 2.5 32.9 19.5 26.2 2.4 32.4 18.7 23.5 2.7 32.1 13.3 304 9 300 165 -4.6 0.2 -3.9 -4.8 11/19/2006 17:00:00 25.5 2.6 33.6 18.7 25.4 2.5 33.2 17.9 22.3 2.7 30.9 14.1 301 8 302 165 -5.1 0.3 -4.2 -5.5 11/19/2006 17:10:00 23.7 2.5 29.4 17.2 23.7 2.5 29.4 17.2 20.2 2.8 26.8 13.7 301 8 302 165 -5.2 0.1 -4.6 -5.5 11/19/2006 17:20:00 22.5 2.1 27.1 16.4 22.4 2.2 27.1 16.4 18.7 2.3 24.8 11.8 299 9 301 165 -5 0.1 -4.4 -5.3 11/19/2006 17:30:00 21.2 2.2 26.3 16.4 21.1 2.1 26.3 16.4 17.8 2.5 24.8 12.2 300 9 302 165 -4.7 0.1 -4.2 -5 11/19/2006 17:40:00 20.8 2.1 25.6 14.9 20.6 2.1 26 15.3 17.5 2.1 23.3 11.8 300 9 293 165 -4.7 0.1 -4.4 -5 11/19/2006 17:50:00 19.6 2.2 25.2 14.1 19.3 2.2 25.2 14.1 16.6 2 22.6 11.5 302 11 298 165 -4.8 0.2 -3.9 -5.3 11/19/2006 18:00:00 19 2 25.2 13.7 18.8 2 24 13 17.3 2.5 24 9.5 314 14 313 165 -4.1 0.1 -3.7 -4.4 11/19/2006 18:10:00 18.6 2.8 28.3 11.1 18.3 2.9 28.3 10.7 17.5 3.1 27.9 9.5 323 17 327 165 -3.3 0.4 -2.6 -4.2 11/19/2006 18:20:00 15.9 2.4 22.6 10.3 15.8 2.5 22.6 7.2 14.9 2.5 23.3 7.6 326 14 315 165 -3 0.1 -2.6 -3.5 11/19/2006 18:30:00 17.3 2 21.8 11.8 17 2.2 22.1 10.7 16.6 2.2 22.1 10.3 331 12 318 165 -2.9 0.2 -2.6 -3.3 11/19/2006 18:40:00 17.5 2.7 26.8 11.5 17.2 2.7 27.5 7.6 16.3 2.8 26.8 9.9 321 15 334 165 -2.7 0.2 -2.1 -3.3 11/19/2006 18:50:00 16.9 2.8 24 9.9 16.7 2.7 23.7 9.1 14.5 2.9 22.1 6.8 309 12 311 165 -3.2 0.1 -2.8 -3.5 11/19/2006 19:00:00 20.8 2.4 27.1 14.9 20.5 2.4 26.8 14.5 17.8 2.5 24.8 12.6 303 9 306 165 -4.4 0.5 -2.8 -5 11/19/2006 19:10:00 24.5 2.1 29.8 17.9 24.4 2.1 29.8 16.8 20.8 2.2 27.9 14.1 301 8 313 165 -5 0.1 -4.6 -5.3 11/19/2006 19:20:00 24.8 2.4 30.9 16.1 24.7 2.5 30.6 15.3 20.9 2.4 27.5 13.7 301 9 304 165 -5.3 0 -4.8 -5.7 11/19/2006 19:30:00 23.4 2.7 31.3 16.8 23.3 2.7 31.3 16.1 20.3 2.7 29.8 13.7 301 10 326 165 -5.4 0.2 -4.8 -5.7 11/19/2006 19:40:00 20.8 3.2 29.1 14.5 20.6 3.2 29.1 14.5 18.1 3.2 29.1 11.8 300 12 325 165 -5 0.4 -3.9 -5.7 11/19/2006 19:50:00 19.7 2.8 27.1 13 19.6 2.7 26.3 12.6 15.7 2.6 22.1 10.3 298 10 298 165 -5 0.3 -3.9 -5.5 11/19/2006 20:00:00 18.5 2.6 23.7 11.5 18.3 2.6 24.8 11.1 14.8 2.4 20.6 8.8 295 10 283 165 -4.8 0.1 -4.4 -5.3 11/19/2006 20:10:00 18.7 2.1 23.3 12.6 18.6 2 23.7 12.6 14.7 2.1 21 9.5 291 10 295 165 -4.8 0.2 -3.9 -5 11/19/2006 20:20:00 20.2 2.7 26.8 11.5 20.1 2.7 26.8 11.5 16.3 2.6 25.6 9.5 297 10 300 165 -4.8 0.2 -4.4 -5.3 11/19/2006 20:30:00 18.2 2.4 24 11.5 18.1 2.4 24 11.5 14.3 1.9 19.9 9.1 298 10 306 165 -5.3 0.1 -4.6 -5.5 11/19/2006 20:40:00 17.4 2.1 24.8 12.6 17.3 2.1 24.8 11.8 15.1 2.3 20.6 9.9 305 12 306 165 -4.1 0.4 -3.3 -4.6 11/19/2006 20:50:00 18.5 2.6 27.5 12.6 18.3 2.6 27.5 11.5 16.1 2.6 25.6 9.9 304 12 288 165 -2.9 0.2 -2.6 -3.3 11/19/2006 21:00:00 21.6 2.1 28.7 15.6 21.5 2.1 28.7 15.3 18.5 2.5 25.6 13 300 11 319 165 -4.3 0.5 -3 -5 11/19/2006 21:10:00 24 2.3 29.8 18.7 23.9 2.3 29.8 18.3 20.7 3.1 28.7 14.1 303 10 321 165 -4.9 0.2 -4.2 -5.3 11/19/2006 21:20:00 24.4 2.3 30.9 17.2 24.4 2.2 30.6 16.8 21.5 2.8 30.2 14.5 305 9 293 165 -5.2 0.1 -4.8 -5.5 11/19/2006 21:30:00 26 1.8 33.2 20.2 26 1.8 32.9 20.2 23.4 2.6 31.3 16.8 304 8 277 165 -5 0.2 -4.6 -5.5 11/19/2006 21:40:00 26.4 1.8 32.1 20.2 26.2 1.8 32.1 20.6 24.4 2.3 32.1 18.3 307 7 314 165 -5.3 0 -5 -5.5 11/19/2006 21:50:00 25.4 2.2 34.8 20.6 25.2 2.3 34.4 20.6 23.7 2.9 32.9 17.6 309 8 310 165 -4.7 0.3 -3.9 -5 11/19/2006 22:00:00 24.3 1.9 30.6 19.1 24.1 2 30.2 18.7 22.2 2.1 28.7 16.1 308 8 312 165 -4.7 0.1 -4.4 -5 11/19/2006 22:10:00 22.9 2.3 32.1 17.2 22.6 2.3 31.8 17.6 20.7 2.3 32.1 14.9 308 9 312 165 -4.4 0.2 -3.7 -4.6 11/19/2006 22:20:00 21.7 2.6 30.6 14.9 21.5 2.6 30.6 14.5 19.3 2.9 27.9 13 307 13 319 165 -4.2 0.4 -3.3 -4.6 11/19/2006 22:30:00 21 2.6 28.3 13.7 20.8 2.6 27.9 13.3 17.8 2.7 26.3 11.8 302 13 312 165 -3.3 0.1 -2.8 -3.5 11/19/2006 22:40:00 23.1 2.3 31.8 16.1 23 2.3 31.3 15.6 20.3 2.8 27.9 14.5 304 10 297 165 -3.3 0.2 -2.8 -3.7 11/19/2006 22:50:00 21.9 2.3 30.6 16.4 21.7 2.3 29.8 16.4 19.2 2.9 27.5 13.3 305 11 303 165 -3.5 0.2 -2.8 -4.2 11/19/2006 23:00:00 20.1 2.5 27.9 13.3 19.9 2.5 27.1 13 17.7 2.8 27.9 10.7 306 11 303 165 -3.9 0.3 -3.3 -4.4 11/19/2006 23:10:00 17.8 1.8 24 12.2 17.6 1.8 23.7 11.8 16.9 2.1 22.1 10.3 322 12 340 165 -3.5 0.3 -2.8 -3.9 11/19/2006 23:20:00 18.1 1.7 22.9 13 17.8 1.8 22.6 11.8 17.5 1.8 23.3 11.8 325 13 332 165 -3 0.2 -2.6 -3.5 11/19/2006 23:30:00 18.1 2.8 24.4 13.7 17.6 2.9 24.8 10.7 17.7 2.8 24.4 12.6 332 12 323 165 -2.6 0.2 -1.9 -2.8 11/19/2006 23:40:00 16.8 2.6 23.7 11.8 16.4 2.6 23.7 11.1 16.2 2.7 24.4 11.1 334 11 351 165 -1.9 0.1 -1.7 -2.1 11/19/2006 23:50:00 20 2.6 26.8 12.2 19.1 2.7 26.3 12.6 19.8 2.8 26.3 11.5 337 12 357 165 -1.7 0 -1.4 -2.1 11/20/2006 00:00:00 17 2.3 22.6 11.8 16.8 2.4 22.6 9.1 16.1 2.4 22.6 10.3 329 13 336 165 -1.8 0 -1.4 -1.9 11/20/2006 00:10:00 17.1 3.1 23.7 9.1 16.9 3.1 23.7 8.4 16.7 3.1 23.3 9.1 332 11 337 165 -1.7 0 -1.4 -1.9 11/20/2006 00:20:00 16.1 2.7 24.8 11.1 15.6 3.1 25.2 8.4 15.4 2.8 24.4 9.9 334 13 346 165 -2 0 -1.7 -2.1 11/20/2006 00:30:00 15.8 2.5 23.3 10.3 15.2 2.5 22.1 9.1 15.4 2.5 22.6 10.3 335 13 325 165 -1.9 0 -1.7 -2.1 11/20/2006 00:40:00 15.2 2.2 22.1 11.1 14.8 2.6 21.4 7.2 15.1 2.4 22.6 9.5 334 12 326 165 -1.8 0.1 -1.4 -2.1 11/20/2006 00:50:00 12 2.8 20.6 5.3 11.9 2.9 20.6 4.2 11.8 2.7 20.2 6.8 335 13 326 165 -1.7 0 -1.4 -1.9 11/20/2006 01:00:00 12.7 2.6 18.3 5.7 12.4 2.7 18.3 5.3 12.6 2.6 17.9 5.7 333 13 340 165 -1.6 0 -1.4 -1.9 11/20/2006 01:10:00 13.3 2.5 20.6 7.6 13.1 2.7 21 7.2 12.8 2.8 20.2 6.8 322 16 338 165 -1.7 0 -1.4 -1.9 11/20/2006 01:20:00 13.2 2.9 24.8 7.6 13.1 2.8 24.4 7.6 11.7 2.7 21 5.7 308 15 282 165 -1.9 0.1 -1.4 -2.1 11/20/2006 01:30:00 14.1 2.5 21 6.5 14 2.5 20.6 6.5 12.1 2.2 18.7 6.8 308 11 303 165 -2.3 0.4 -1.4 -3 11/20/2006 01:40:00 15.1 1.9 19.5 9.9 15 1.9 19.5 9.9 12.4 1.6 17.6 9.1 302 9 303 165 -3.3 0.3 -2.6 -3.7 11/20/2006 01:50:00 16.6 1.9 23.3 10.7 16.4 1.8 22.6 11.1 13.5 1.7 19.5 9.1 298 10 295 165 -3.8 0 -3.5 -3.9 11/20/2006 02:00:00 16.9 1.6 21.4 12.2 16.8 1.6 21.4 11.5 13.7 2 19.5 9.1 302 10 295 165 -3.9 0.1 -3.5 -4.2 11/20/2006 02:10:00 16.3 1.7 22.1 11.5 16.1 1.7 21.8 11.5 14.6 2.2 20.6 9.5 308 10 307 165 -3.5 0.1 -3.3 -3.7 11/20/2006 02:20:00 19.2 1.9 22.6 14.1 19 1.9 22.6 13.3 15.9 1.7 20.6 11.1 303 8 314 165 -3.9 0.1 -3.3 -4.2 11/20/2006 02:30:00 20.8 1.3 23.7 16.8 20.7 1.3 23.7 16.8 17.4 1.8 21.4 12.6 305 8 300 165 -4 0 -3.5 -4.2 11/20/2006 02:40:00 20.8 1.3 24 16.1 20.7 1.3 24 15.6 18.5 1.7 22.1 13.7 307 7 310 165 -4 0 -3.7 -4.2 11/20/2006 02:50:00 21.1 1.5 25.2 16.4 20.9 1.5 25.2 16.4 18.2 2 23.3 12.2 305 9 298 165 -3.8 0 -3.5 -3.9 11/20/2006 03:00:00 20.7 1.6 26.8 16.4 20.6 1.6 26.8 15.6 18.2 2 24.4 13 306 7 307 165 -3.8 0 -3.5 -3.9 11/20/2006 03:10:00 22.3 1.5 26.3 18.3 22.2 1.5 26 17.9 19.7 1.7 24 15.3 306 8 285 165 -3.8 0 -3.5 -3.9 11/20/2006 03:20:00 22.4 1.7 26.3 17.9 22.2 1.7 26 17.6 20.5 1.7 24.4 14.5 309 7 308 165 -3.8 0 -3.5 -3.9 11/20/2006 03:30:00 20.3 2 26.8 14.5 20.1 1.8 26.3 15.3 17.6 2 22.1 12.6 307 8 310 165 -3.8 0 -3.5 -3.9 11/20/2006 03:40:00 18 1.5 21.4 13.3 17.7 1.3 21 13.7 15 2.1 19.5 8 303 8 303 165 -4 0.2 -3.5 -4.4 11/20/2006 03:50:00 17.5 1.7 21.8 13 17.3 1.7 21 12.6 15.1 1.9 19.5 9.5 306 7 305 165 -4.4 0 -3.9 -4.6 11/20/2006 04:00:00 17.7 1.7 21.8 13 17.5 1.7 21.4 12.6 15.4 1.7 19.9 11.1 307 7 305 165 -4.5 0 -4.4 -4.6 11/20/2006 04:10:00 18.3 2 22.9 12.6 18 1.9 22.1 13 15.5 1.7 20.2 11.5 305 11 302 165 -4.5 0 -4.4 -4.6 11/20/2006 04:20:00 17.2 1.7 21 11.8 16.9 1.6 20.2 11.5 14.5 2.2 19.9 9.5 305 10 295 165 -4.5 0 -4.4 -4.6 11/20/2006 04:30:00 17.8 1.5 21.4 13.3 17.5 1.5 21.4 13.7 16.1 1.5 19.9 11.8 310 7 296 165 -4.4 0 -4.2 -4.6 11/20/2006 04:40:00 18.9 1.5 22.1 14.1 18.7 1.5 22.1 14.5 17.4 1.6 21.4 12.2 311 6 311 165 -4.2 0 -3.9 -4.4 11/20/2006 04:50:00 18.6 2 23.3 12.2 18.4 2 22.6 12.2 15.5 2.3 21 9.1 303 9 299 165 -4.1 0 -3.7 -4.4 11/20/2006 05:00:00 19 1.7 22.9 14.1 18.9 1.7 23.3 13 16.3 2.2 23.3 11.1 306 8 302 165 -4 0 -3.7 -4.4 11/20/2006 05:10:00 18.7 1.7 22.9 14.5 18.5 1.7 22.6 14.1 14.8 2 21 11.1 302 8 306 165 -4.2 0 -3.9 -4.4 11/20/2006 05:20:00 17.2 1.2 20.6 14.1 17.1 1.3 20.2 13.7 13.4 1.7 17.9 9.9 301 8 314 165 -4.4 0 -4.2 -4.6 11/20/2006 05:30:00 15.3 1.5 21 11.1 15.1 1.5 20.6 11.1 12.8 2.2 18.7 8.8 305 9 325 165 -4.4 0 -4.2 -4.6 11/20/2006 05:40:00 13.8 1.9 19.5 9.1 13.7 1.9 19.5 9.1 11.4 2 18.3 6.8 304 10 305 165 -4.4 0 -4.2 -4.6 11/20/2006 05:50:00 13.3 1.9 17.9 9.1 13.2 1.9 17.6 9.1 11.3 2 18.7 7.2 302 13 317 165 -4.3 0 -3.9 -4.6 11/20/2006 06:00:00 13.4 1.7 17.2 8.8 13.3 1.7 17.2 8.8 10.8 1.8 16.4 6.8 299 12 302 165 -4.5 0 -4.2 -4.6 11/20/2006 06:10:00 14.6 1.6 18.3 10.3 14.5 1.6 18.3 10.3 12.2 1.9 17.6 8.4 302 10 307 165 -4.6 0 -4.4 -4.6 11/20/2006 06:20:00 15.1 1.5 18.3 11.5 14.9 1.5 18.3 11.1 13.5 1.7 17.6 8.8 309 8 303 165 -4.7 0.1 -4.4 -4.8 11/20/2006 06:30:00 18 1.2 21 14.9 17.8 1.2 21 14.5 15.5 1.8 20.2 11.1 307 8 302 165 -4.7 0 -4.4 -5 11/20/2006 06:40:00 17 2 21 12.6 16.9 2 21 12.2 15.8 2 19.5 10.3 310 5 307 165 -4.8 0 -4.6 -5 11/20/2006 06:50:00 17.1 1.7 20.2 12.6 17 1.7 20.2 12.2 15.1 1.7 19.1 9.9 307 8 296 165 -4.9 0 -4.6 -5 11/20/2006 07:00:00 13.9 1.7 20.6 9.1 13.6 1.7 20.6 9.1 13.1 2.1 19.5 7.2 315 9 313 165 -5 0 -4.6 -5.3 11/20/2006 07:10:00 11.8 1.5 15.6 8.4 11.5 1.5 15.6 8 11.2 1.7 14.9 7.2 320 10 307 165 -5 0 -4.6 -5.3 11/20/2006 07:20:00 11.5 1.7 16.8 7.2 11.4 1.7 16.4 7.2 10.5 1.5 14.9 6.5 314 10 320 165 -5 0 -4.6 -5.3 11/20/2006 07:30:00 11.5 1.6 16.8 7.6 11.4 1.6 16.4 7.6 10.1 1.5 15.3 6.1 308 11 307 165 -5 0 -4.6 -5.3 11/20/2006 07:40:00 12.4 1.5 16.4 8.4 12.2 1.5 16.4 8.4 11.7 1.5 15.6 7.6 318 11 301 165 -4.9 0 -4.6 -5.3 11/20/2006 07:50:00 10.5 1.7 15.3 6.8 10.4 1.7 14.9 6.5 10.1 1.7 15.6 6.5 326 10 321 165 -4.9 0 -4.6 -5.3 11/20/2006 08:00:00 8.9 1.4 12.6 4.9 8.7 1.4 12.2 5.3 8.1 1.1 11.8 4.9 330 15 313 165 -5.3 0.1 -4.8 -5.5 11/20/2006 08:10:00 9.8 1.6 14.5 5.3 9.4 1.5 14.5 5.7 9.3 1.5 13 4.9 332 14 349 165 -5.3 0 -5 -5.5 11/20/2006 08:20:00 8.6 1.1 11.1 5.3 8.4 1 10.7 5.3 8.1 1.2 10.7 4.2 324 12 318 165 -5.5 0 -5 -5.7 11/20/2006 08:30:00 10 1.7 14.5 6.5 9.7 1.9 14.9 4.6 9.5 1.7 14.1 5.3 337 12 341 165 -5.5 0 -5.3 -5.7 11/20/2006 08:40:00 9.1 1.1 12.6 6.1 9 1.2 12.2 5.7 8.8 1.2 12.2 5.7 331 10 314 165 -5.6 0 -5.3 -5.7 11/20/2006 08:50:00 12.4 1.8 17.6 8 12.2 1.8 17.6 8 11.6 1.7 16.4 8 317 9 302 165 -5.4 0.2 -5 -5.7 11/20/2006 09:00:00 11.6 1.1 14.9 8.4 11.3 1.1 14.1 8.4 9.9 1.2 13.3 7.2 307 8 318 165 -5.4 0 -5 -5.7 11/20/2006 09:10:00 11 1.1 14.5 8 10.8 1 14.1 8 9.2 1.1 12.6 6.8 308 7 299 165 -5.4 0 -5 -5.7 11/20/2006 09:20:00 9.8 1.5 14.1 6.1 9.6 1.4 13.3 6.5 8.5 1.6 13.3 5.3 308 11 305 165 -5 0 -4.8 -5.3 11/20/2006 09:30:00 9.6 1.2 14.9 5.7 9.5 1.2 14.5 6.1 8.1 1.1 11.1 5.3 308 11 303 165 -5 0 -4.6 -5.3 11/20/2006 09:40:00 8.9 1.2 11.8 6.1 8.8 1.2 11.8 5.3 7.8 1.2 10.7 4.6 309 13 304 165 -4.9 0 -4.6 -5 11/20/2006 09:50:00 8.5 1.3 12.6 4.9 8.3 1.3 12.2 4.9 7.2 1.2 10.3 3.4 305 12 301 165 -4.8 0 -4.6 -5 11/20/2006 10:00:00 8.5 1.9 13 4.9 8.4 1.9 13 4.6 8.1 1.8 12.2 3.8 322 14 299 165 -4.8 0 -4.6 -5 11/20/2006 10:10:00 9.7 1.3 13.3 6.1 9.4 1.5 13.3 5.3 9.3 1.4 13 6.1 338 10 344 165 -4.7 0 -4.4 -4.8 11/20/2006 10:20:00 8.1 1.1 11.8 5.3 7.7 1.1 11.5 4.9 7.6 1.2 11.1 4.9 330 18 338 165 -4.7 0 -4.4 -4.8 11/20/2006 10:30:00 11 2.9 17.2 5.7 10.8 3.2 17.9 5.3 10.6 2.9 17.2 5.3 337 9 343 165 -4.7 0 -4.4 -4.6 11/20/2006 10:40:00 14.2 1.6 18.3 9.5 14.2 1.8 18.7 9.1 13.9 1.7 17.9 8.8 343 7 341 165 -4.5 0 -4.4 -4.6 11/20/2006 10:50:00 13 1.5 16.8 7.2 12.7 1.8 16.8 7.2 12.6 1.6 15.6 6.8 341 9 353 165 -4.5 0 -4.2 -4.6 11/20/2006 11:00:00 13.7 1.4 19.1 9.5 13.3 1.8 19.5 8 13.1 1.4 17.2 9.1 342 7 344 165 -4.7 0 -4.4 -4.6 11/20/2006 11:10:00 11.6 1.5 15.3 8 11.2 1.7 16.1 7.2 11.2 1.7 14.5 7.6 341 9 343 165 -4.7 0 -4.4 -4.6 11/20/2006 11:20:00 11 1.4 14.1 7.6 10.7 1.7 14.5 5.7 10.3 1.4 13 6.8 342 8 339 165 -4.4 0 -4.2 -4.6 11/20/2006 11:30:00 12.4 1.4 15.6 8.4 12.2 1.7 16.1 6.5 11.5 1.5 15.3 7.6 339 8 330 165 -4.5 0.1 -3.9 -4.8 11/20/2006 11:40:00 13.1 1.4 17.6 9.1 12.5 2.1 17.2 6.8 12.3 1.5 16.4 7.2 345 9 334 165 -4.7 0 -4.4 -4.8 11/20/2006 11:50:00 13.3 1.7 17.2 8.4 13.1 2.1 17.2 6.5 12.9 1.7 17.9 7.2 341 11 338 165 -4.6 0 -4.4 -4.6 11/20/2006 12:00:00 13.3 1.6 17.2 9.1 12.5 2.3 17.6 7.2 13 1.8 17.9 6.8 341 12 325 165 -4.2 0.1 -3.7 -4.4 11/20/2006 12:10:00 14.1 2.4 19.9 8.8 13.9 2.6 19.9 6.8 14.1 2.5 20.2 9.5 338 8 338 165 -3.7 0 -3.5 -3.9 11/20/2006 12:20:00 13.1 2.2 18.7 7.2 12.9 2.4 17.9 5.3 12.7 2.2 18.3 7.6 332 14 328 165 -3.7 0 -3.3 -3.9 11/20/2006 12:30:00 12.6 2.1 18.7 7.6 12.5 2.2 18.7 8 12.1 2.4 19.1 6.8 324 9 326 165 -4 0.2 -3.5 -4.4 11/20/2006 12:40:00 8.1 1.4 13 4.6 8 1.5 12.6 4.6 7.5 1.3 11.1 4.6 326 15 348 165 -4.4 0 -4.2 -4.6 11/20/2006 12:50:00 12.1 2.9 19.5 6.8 11.9 3.1 20.2 6.1 11.6 3.1 19.9 5.7 334 10 346 165 -4.7 0.1 -4.4 -4.8 11/20/2006 13:00:00 13.8 2.1 19.1 9.1 13.4 2.3 18.7 7.6 13.3 2.3 18.7 7.6 338 11 329 165 -4.7 0 -4.4 -4.8 11/20/2006 13:10:00 13.5 1.7 17.6 9.1 13.1 2.2 17.6 5.7 12.8 1.7 16.4 8 340 10 334 165 -4.5 0 -4.4 -4.6 11/20/2006 13:20:00 11.9 2.4 17.9 7.2 10.9 2.3 16.4 4.6 11.9 2.6 18.7 7.2 341 11 3 165 -4.4 0 -4.2 -4.6 11/20/2006 13:30:00 11.7 2.1 16.4 7.2 11.6 2.1 16.4 6.8 11.1 2.2 16.4 6.5 329 11 338 165 -4.1 0.1 -3.7 -4.6 11/20/2006 13:40:00 11.5 2.5 16.1 4.9 10.8 3.1 16.4 4.2 11.4 2.3 17.2 4.9 342 12 339 165 -4 0.1 -3.7 -4.4 11/20/2006 13:50:00 16.6 2.6 22.1 10.7 16.3 2.9 23.3 8 16.2 2.8 22.1 10.3 339 9 341 165 -3.9 0 -3.7 -4.2 11/20/2006 14:00:00 16.1 2.7 21.4 9.5 15.8 2.9 21.8 8.8 15.5 2.8 21.4 8.4 336 10 340 165 -4.2 0.1 -3.5 -4.6 11/20/2006 14:10:00 16 2.7 22.1 10.3 15.8 2.8 22.6 8.8 15.7 2.7 22.1 8.8 337 9 338 165 -4.4 0 -4.2 -4.6 11/20/2006 14:20:00 14.9 2.9 23.3 7.6 14.5 3.2 22.9 7.6 14.1 3.1 23.3 6.8 333 11 326 165 -4.2 0 -3.9 -4.4 11/20/2006 14:30:00 13.7 2 21 7.2 13.2 2.3 20.6 6.5 13.2 2.1 19.5 7.6 336 11 329 165 -3.9 0 -3.7 -4.4 11/20/2006 14:40:00 12.9 2 19.1 8.4 12.6 2.3 19.1 6.5 12.2 2.2 18.7 6.8 327 13 319 165 -4.1 0.1 -3.5 -4.4 11/20/2006 14:50:00 12.5 2.4 19.1 4.6 12.3 2.4 19.1 5.3 12.1 2.5 18.7 5.3 329 10 330 165 -4.5 0 -3.9 -4.6 11/20/2006 15:00:00 14.2 1.8 19.5 9.1 12.9 2.8 20.6 6.8 14.3 1.9 21.4 9.1 346 10 336 165 -4.5 0 -4.2 -4.6 11/20/2006 15:10:00 11.2 2.1 19.1 6.5 11 2 17.6 6.5 10.8 1.9 17.9 7.2 333 13 358 165 -4.5 0.2 -3.9 -4.6 11/20/2006 15:20:00 12.4 2.6 18.7 6.8 12 2.6 18.7 4.9 12 2.7 17.9 6.8 335 11 358 165 -4.4 0.1 -3.7 -4.6 11/20/2006 15:30:00 13.7 2.4 18.3 6.1 12.9 2.7 18.3 6.1 13.2 2.3 17.9 5.3 340 12 320 165 -4.7 0 -4.4 -4.6 11/20/2006 15:40:00 14.2 2.1 19.1 9.9 14 2.3 19.5 8 13.8 2 20.2 9.1 337 9 338 165 -4.6 0 -4.4 -4.6 11/20/2006 15:50:00 13.8 1.6 19.5 10.3 13.2 2.2 18.3 6.5 13.5 1.5 17.9 9.5 342 10 355 165 -4.5 0 -4.2 -4.6 11/20/2006 16:00:00 12.4 2.3 17.2 5.7 11.7 2.6 17.2 5.7 12.4 2.3 17.6 6.1 341 12 316 165 -4.6 0 -4.2 -4.6 11/20/2006 16:10:00 12.8 2.5 19.5 6.8 12.7 2.5 19.1 6.5 12.1 2.6 20.6 5.7 329 11 310 165 -4.7 0.1 -4.4 -4.8 11/20/2006 16:20:00 8.9 1.6 13 4.6 8 1.7 13 3.4 8.2 1.7 13.3 3 345 15 6 165 -4.8 0 -4.4 -4.8 11/20/2006 16:30:00 9.9 2.3 15.3 3 9.4 2.3 14.5 2.6 9.3 2.3 14.5 2.6 327 26 6 165 -4.9 0 -4.6 -5.3 11/20/2006 16:40:00 11.1 1.7 16.8 6.8 10.9 1.8 17.2 5.7 10.4 1.7 15.6 5.7 324 16 309 165 -5.2 0.1 -4.8 -5.5 11/20/2006 16:50:00 11.3 1.9 15.3 6.8 11.1 1.9 15.3 6.8 10.3 1.8 14.9 5.7 315 20 310 165 -5.2 0 -4.8 -5.5 11/20/2006 17:00:00 11.4 1.9 16.8 6.8 11.3 2 17.9 5.3 10.8 2.2 17.6 6.8 323 16 341 165 -5.2 0 -4.8 -5.5 11/20/2006 17:10:00 8.6 2 14.1 4.6 8.5 2 13.7 3.8 7.9 1.8 13 4.2 324 16 322 165 -5.2 0 -4.8 -5.5 11/20/2006 17:20:00 10 1.9 15.6 4.9 9.8 1.9 15.6 4.6 9.9 2.1 14.9 4.9 329 13 339 165 -4.8 0 -4.6 -5.3 11/20/2006 17:30:00 10.5 2.7 21.8 5.3 10.3 2.8 22.1 4.6 10.1 2.9 20.6 5.3 326 11 333 165 -4.8 0 -4.6 -5 11/20/2006 17:40:00 14.8 3.1 22.6 8.8 14.3 3.5 22.6 5.7 14.5 3.2 21.8 8 339 12 328 165 -4.7 0 -4.4 -4.8 11/20/2006 17:50:00 14.4 2.7 20.6 8 14.2 2.8 21.8 6.5 14.3 2.7 21.8 9.1 337 9 342 165 -4.5 0 -4.4 -4.6 11/20/2006 18:00:00 17.8 2.6 25.2 11.1 17.3 3.3 25.2 8 17.2 2.7 23.3 10.3 339 12 339 165 -4.5 0 -4.4 -4.6 11/20/2006 18:10:00 18 2.8 27.1 11.1 17.3 3.5 27.9 6.8 17.4 3.1 24.4 9.1 337 15 338 165 -4.5 0 -4.4 -4.6 11/20/2006 18:20:00 15.1 3.5 24.8 4.9 14.5 3.6 25.6 4.6 14.7 3.5 24 3 336 17 339 165 -4.5 0 -4.4 -4.6 11/20/2006 18:30:00 15.6 2.5 24 9.1 15.2 2.7 24 8 15.4 2.6 23.3 8.8 333 13 326 165 -4.7 0 -4.4 -4.6 11/20/2006 18:40:00 16.7 2.7 22.6 7.6 16.2 2.9 22.9 6.8 16.3 2.8 23.3 7.2 338 10 339 165 -4.7 0 -4.4 -4.6 11/20/2006 18:50:00 14.7 2.9 22.1 8.8 14.5 2.8 21.8 8.4 14.2 3.2 22.1 7.2 330 11 326 165 -4.7 0 -4.4 -4.6 11/20/2006 19:00:00 13.6 2.5 21.4 6.5 13.4 2.6 21 5.7 12.8 2.4 21 7.2 326 21 332 165 -4.7 0 -4.4 -4.8 11/20/2006 19:10:00 16.1 2.4 23.3 10.7 15.7 2.7 22.1 8.4 16.1 2.6 23.3 9.5 337 13 312 165 -4.8 0 -4.4 -5 11/20/2006 19:20:00 16.7 2.3 23.7 11.5 16.7 2.5 24.8 10.3 16.5 2.3 23.7 11.5 336 10 345 165 -4.9 0 -4.6 -5 11/20/2006 19:30:00 18.6 2.9 26 11.1 18.3 3.2 26.8 10.3 18.2 3.3 24.8 8.8 336 14 330 165 -4.8 0 -4.6 -5 11/20/2006 19:40:00 18.6 2.1 24 12.6 17.6 2.9 25.2 9.1 18.3 2.1 24.8 13.7 343 10 329 165 -4.8 0 -4.6 -5 11/20/2006 19:50:00 15.5 2.2 21.4 9.9 14.6 2.5 20.2 8 15.1 2.5 21.4 8.8 344 11 356 165 -4.9 0 -4.6 -5 11/20/2006 20:00:00 15.7 1.9 20.6 10.3 15 2.4 20.6 7.6 15.2 2.1 21 8 338 13 338 165 -4.9 0 -4.6 -5 11/20/2006 20:10:00 18 1.8 21.8 13.3 17.2 2.5 22.1 10.7 17.8 2.1 22.6 11.8 342 10 359 165 -4.8 0 -4.6 -5 11/20/2006 20:20:00 17.1 2 23.3 10.7 16.9 2.1 23.7 10.3 16.2 2.1 22.1 11.1 337 9 351 165 -4.8 0 -4.4 -5 11/20/2006 20:30:00 18.3 2.5 24 9.9 18 2.9 24.8 9.1 17.2 2.6 23.7 9.9 341 8 347 165 -4.8 0 -4.4 -4.8 11/20/2006 20:40:00 16.8 2.3 23.3 9.5 16.6 2.6 24.8 9.5 15.8 2.3 22.1 9.9 341 8 351 165 -4.7 0 -4.6 -4.8 11/20/2006 20:50:00 15.1 2.2 21 9.9 14.6 2.4 20.2 7.6 14.1 2.4 19.9 9.1 338 12 349 165 -4.8 0 -4.4 -4.8 11/20/2006 21:00:00 17.5 2.3 22.9 10.7 17.3 2.7 23.3 9.5 17.1 2.5 22.9 10.3 341 8 347 165 -4.7 0 -4.6 -5 11/20/2006 21:10:00 18.8 2.2 23.7 11.1 18.3 2.7 23.7 10.7 18.1 2.4 24 11.5 341 8 357 165 -4.8 0 -4.4 -5 11/20/2006 21:20:00 18.2 2.2 25.6 12.2 18.1 2.6 26 9.9 17.3 2.2 22.9 12.2 339 8 339 165 -4.8 0 -4.6 -4.8 11/20/2006 21:30:00 17.5 2.1 22.6 11.5 16.5 2.5 22.9 9.5 17.2 2.4 22.9 9.5 345 10 354 165 -4.8 0 -4.6 -5 11/20/2006 21:40:00 16.6 2.2 21.8 11.1 16.5 2.5 22.6 9.9 16.1 2.2 21 11.5 340 8 345 165 -4.8 0 -4.6 -5 11/20/2006 21:50:00 17 2.4 22.1 10.7 16.7 2.4 21.4 10.7 16.1 2.7 21.8 9.5 335 9 347 165 -4.8 0 -4.6 -5 11/20/2006 22:00:00 13.2 2.9 19.9 7.2 12.8 2.8 19.9 6.8 12.1 2.9 18.7 5.7 333 13 352 165 -4.8 0 -4.4 -5 11/20/2006 22:10:00 15.1 2.3 20.2 9.1 14.5 2.8 21.4 6.8 14.3 2.2 19.9 8.4 341 13 344 165 -4.7 0 -4.6 -4.8 11/20/2006 22:20:00 13.6 1.7 19.1 9.1 13.3 1.8 19.1 9.5 13.2 1.9 18.7 8 337 9 344 165 -4.7 0 -4.4 -4.8 11/20/2006 22:30:00 13.1 1.8 19.1 8 12.9 2.1 18.7 6.5 12.5 2 16.8 6.5 341 8 344 165 -4.8 0 -4.4 -5 11/20/2006 22:40:00 9.8 1.7 14.5 5.3 9.3 1.7 14.9 4.6 8.5 1.9 14.1 3.8 341 13 357 165 -4.9 0 -4.4 -5.3 11/20/2006 22:50:00 11.4 2 17.2 5.3 10.8 2.2 16.8 5.3 10.2 2 15.6 5.7 341 10 354 165 -5 0 -4.8 -5.3 11/20/2006 23:00:00 13.9 2 18.7 7.6 13.7 2.2 19.1 5.3 13.1 2.3 18.7 6.1 338 9 337 165 -4.9 0 -4.6 -5 11/20/2006 23:10:00 15.1 2.5 21.4 9.9 14.7 2.6 21.8 8.4 14.5 2.4 20.2 9.5 341 11 349 165 -4.9 0 -4.6 -5 11/20/2006 23:20:00 10.8 1.9 16.1 6.5 10.6 1.9 15.6 5.3 10.2 1.9 14.9 4.9 334 10 340 165 -5 0 -4.6 -5.3 11/20/2006 23:30:00 9.8 2.8 16.8 4.9 9.8 2.8 17.2 4.6 8.8 2.9 16.4 2.6 324 14 334 165 -5.2 0 -4.8 -5.5 11/20/2006 23:40:00 6.6 2.2 12.2 1.1 6.2 2.2 11.8 1.5 5.6 2.3 12.2 0.7 341 33 325 165 -5.3 0 -5 -5.5 11/20/2006 23:50:00 7.1 2.4 12.6 0.7 6.4 2.2 11.1 1.1 6.5 2.4 13.3 0.4 347 22 1 165 -5.2 0 -5 -5.5 11/21/2006 00:00:00 11.5 3.2 19.1 5.3 10.9 3.2 19.9 5.3 11 3.2 19.5 5.3 336 17 333 165 -4.9 0 -4.6 -5.3 11/21/2006 00:10:00 8.8 2 14.1 4.6 8.4 2.1 13.7 4.2 8.2 2.2 14.5 4.2 335 15 328 165 -4.9 0 -4.6 -5 11/21/2006 00:20:00 9.2 2.7 18.7 2.3 9 2.7 18.7 2.3 8.7 2.6 17.2 4.2 326 19 348 165 -4.8 0 -4.6 -5 11/21/2006 00:30:00 6.7 2.2 13.3 3.4 6.2 2.1 12.2 2.6 5.9 2.1 13.3 2.3 339 21 350 165 -4.8 0 -4.6 -5 11/21/2006 00:40:00 13.6 2.5 19.9 6.1 12.9 2.6 18.7 5.7 12.7 2.6 19.9 5.3 341 13 334 165 -4.9 0.1 -4.6 -5.3 11/21/2006 00:50:00 13.1 2.6 21.8 8 12.9 2.7 20.6 7.6 12.4 2.6 19.9 6.5 331 12 330 165 -4.7 0 -4.4 -4.8 11/21/2006 01:00:00 12.9 2.3 19.9 7.6 12.4 2.4 19.9 6.8 11.8 2.2 19.9 6.8 338 12 334 165 -4.7 0 -4.4 -4.6 11/21/2006 01:10:00 10.9 2.8 18.3 5.3 10.6 2.8 17.2 4.6 10.3 3.1 19.1 4.2 329 15 5 165 -4.6 0 -4.4 -4.6 11/21/2006 01:20:00 9.8 2.8 17.2 4.6 9.4 2.6 16.4 4.2 9.2 2.9 16.8 2.6 328 19 358 165 -4.4 0 -4.2 -4.6 11/21/2006 01:30:00 12.3 1.9 17.6 7.6 12.1 2 17.2 7.6 11.6 2.3 17.6 5.3 335 10 331 165 -4.7 0 -4.4 -4.6 11/21/2006 01:40:00 9.8 2.5 16.1 4.9 9.3 2.5 16.1 4.2 8.8 2.6 15.3 3 331 17 336 165 -4.6 0 -4.4 -4.6 11/21/2006 01:50:00 8.7 2.1 13.7 4.6 8.4 2.1 14.5 3.4 8 2 12.6 3.8 330 15 340 165 -4.7 0.1 -4.4 -4.8 11/21/2006 02:00:00 10.6 2.5 16.1 5.3 10.5 2.6 16.1 4.9 10.2 2.7 16.8 4.6 336 10 333 165 -4.8 0.1 -4.4 -5 11/21/2006 02:10:00 10.4 2.1 14.5 5.3 10.2 2.1 14.9 4.9 10 1.9 16.1 5.3 332 10 312 165 -4.4 0 -4.2 -4.6 11/21/2006 02:20:00 11.9 2.4 17.2 7.2 11.7 2.5 17.2 6.8 11.5 2.5 16.8 5.7 333 12 338 165 -4.4 0 -3.9 -4.6 11/21/2006 02:30:00 10.7 2.2 19.9 5.7 10.4 2.3 20.6 4.9 10.4 2.3 18.7 5.3 337 11 342 165 -4.4 0 -4.2 -4.6 11/21/2006 02:40:00 12.5 2.6 18.3 6.5 12.4 2.5 17.9 6.1 11.8 2.7 18.3 5.7 332 12 324 165 -4.4 0 -4.2 -4.6 11/21/2006 02:50:00 13.4 2.4 19.9 7.6 13.1 2.4 18.3 7.6 12.9 2.5 20.2 6.8 334 12 345 165 -4.2 0.1 -3.9 -4.4 11/21/2006 03:00:00 13.4 2.4 18.7 7.2 13.4 2.5 18.7 6.8 12.9 2.5 19.9 6.5 334 12 340 165 -4 0.1 -3.5 -4.2 11/21/2006 03:10:00 11.9 2.3 17.6 7.2 11.8 2.3 17.6 6.8 11.3 2.4 16.8 5.3 331 12 335 165 -4 0 -3.5 -4.2 11/21/2006 03:20:00 12.8 2.1 18.7 8 12.4 2.1 17.9 6.1 11.8 2 18.7 7.2 335 11 349 165 -3.7 0 -3.5 -3.9 11/21/2006 03:30:00 12 2.1 17.9 6.8 11.1 2.3 17.6 6.1 10.9 2.3 17.2 5.7 339 15 323 165 -3.8 0 -3.5 -3.9 11/21/2006 03:40:00 11.8 1.8 15.3 6.1 11.5 1.9 16.1 5.3 10.8 2 14.9 6.1 336 10 340 165 -3.8 0 -3.5 -3.9 11/21/2006 03:50:00 11.1 1.5 14.9 6.1 10.7 1.5 14.5 6.1 10.4 1.7 14.5 5.3 340 13 350 165 -3.7 0 -3.5 -3.9 11/21/2006 04:00:00 12.2 2.3 18.7 7.6 11.6 2.3 17.6 6.8 11.3 2.1 16.8 6.5 341 12 349 165 -3.5 0 -3.3 -3.7 11/21/2006 04:10:00 12.2 1.8 16.1 7.6 12.1 1.8 16.1 7.6 11.5 1.9 15.6 6.5 329 12 332 165 -3.8 0 -3.3 -3.9 11/21/2006 04:20:00 12 2.3 18.3 6.5 11.3 2.3 16.4 6.1 11.4 2.5 16.4 6.1 341 11 356 165 -3.5 0.1 -3.3 -3.9 11/21/2006 04:30:00 11 1.9 15.3 6.8 10.7 2.1 15.3 5.7 10.4 2 14.5 4.9 339 10 344 165 -3.6 0 -3.3 -3.7 11/21/2006 04:40:00 11.1 1.4 15.3 6.8 10.8 1.5 14.9 6.1 10.6 1.5 15.3 6.1 337 11 357 165 -3.8 0 -3.5 -4.2 11/21/2006 04:50:00 12.2 2 17.2 7.2 11.6 1.9 16.1 6.8 11.7 2 17.2 7.2 341 11 353 165 -3.8 0 -3.5 -3.9 11/21/2006 05:00:00 10.4 1.8 14.9 6.1 9.9 1.8 14.9 5.3 9.2 1.8 14.5 4.6 338 14 346 165 -4 0.1 -3.5 -4.2 11/21/2006 05:10:00 8.2 2.3 14.5 2.6 7.8 2.3 14.5 1.5 7.1 2.6 13.3 1.1 331 17 355 165 -4.2 0.1 -3.7 -4.4 11/21/2006 05:20:00 6.5 2.5 13 0.4 6.3 2.4 12.6 0.7 4.6 2.1 11.1 0.7 312 32 329 165 -4.3 0 -3.9 -4.4 11/21/2006 05:30:00 6.5 2 11.8 1.1 6.4 2.1 11.5 0.4 5.1 2.1 9.9 0.4 321 29 297 165 -4.3 0 -3.9 -4.4 11/21/2006 05:40:00 8 1.6 13.3 4.6 7.8 1.7 12.2 4.2 6.3 1.7 10.7 2.3 324 17 325 165 -4.4 0 -3.9 -4.6 11/21/2006 05:50:00 8.2 2.3 14.9 1.5 8 2.3 14.5 0.4 6.8 2.6 13.3 0.7 325 18 349 165 -4.3 0 -4.2 -4.6 11/21/2006 06:00:00 7.5 1.7 12.6 3.8 7.5 1.7 12.6 3.8 6.3 1.7 10.7 2.6 318 14 342 165 -4.2 0.1 -3.9 -4.6 11/21/2006 06:10:00 6.7 1.7 12.2 3 6.5 1.9 12.2 2.6 5.5 1.9 11.5 1.5 323 16 308 165 -4.3 0.1 -3.9 -4.6 11/21/2006 06:20:00 6.3 1.9 12.2 1.9 6 1.8 11.8 0.7 4.9 1.9 10.7 0.4 334 19 342 165 -4.3 0 -3.7 -4.4 11/21/2006 06:30:00 8.7 1.7 13.7 3.8 8 1.8 13 3.4 7.8 1.7 11.5 3 346 9 344 165 -4.3 0 -3.9 -4.6 11/21/2006 06:40:00 7.6 2.2 12.6 2.3 6.9 1.8 11.8 3 6.8 2.2 11.5 2.3 339 17 354 165 -4.2 0 -3.9 -4.4 11/21/2006 06:50:00 6.7 1.5 13 3.4 6.5 1.6 13.3 3.4 6 1.5 11.1 3 320 16 286 165 -4.3 0 -3.9 -4.4 11/21/2006 07:00:00 8.4 1.2 12.2 5.7 8.2 1.2 11.8 5.7 7.4 1.2 10.3 4.6 311 9 304 165 -4.2 0 -3.9 -4.4 11/21/2006 07:10:00 6 1.3 9.9 3 5.7 1.3 9.9 3 5.6 1.2 8.8 3 331 17 336 165 -4.4 0 -3.7 -4.6 11/21/2006 07:20:00 4.8 1 7.6 3 4.6 0.9 7.2 2.6 4.5 0.9 6.8 2.6 326 12 356 165 -4.6 0 -4.4 -4.6 11/21/2006 07:30:00 6.1 1.1 9.5 3.8 6 1.1 8.8 3.8 5 1 8 2.6 308 12 293 165 -4.7 0.1 -4.2 -4.8 11/21/2006 07:40:00 7.5 1.5 11.1 4.2 7.4 1.4 10.7 3.8 6.1 1.3 9.9 3 303 9 301 165 -4.7 0.1 -4.4 -5 11/21/2006 07:50:00 7.4 1.6 11.5 4.2 7.3 1.5 11.5 4.2 6.1 1.4 9.5 3 305 9 295 165 -4.6 0 -4.4 -4.8 11/21/2006 08:00:00 7.3 1.5 11.1 3.8 7.2 1.4 10.7 4.2 6.3 1.2 8.8 3.4 311 12 294 165 -4.6 0 -4.4 -4.6 11/21/2006 08:10:00 7.2 1.6 10.7 3.4 7.1 1.6 10.7 3 6.1 1.5 10.3 1.5 305 17 307 165 -4.4 0.1 -4.2 -4.6 11/21/2006 08:20:00 6.6 2 11.1 1.5 6.6 1.8 11.1 2.6 5.2 1.9 10.3 0.4 297 23 296 165 -4.4 0 -3.9 -4.6 11/21/2006 08:30:00 4.8 1.9 10.7 0.7 4.6 2.1 10.7 0.4 4.1 1.7 9.9 0.4 314 24 298 165 -4.2 0.3 -3.5 -4.6 11/21/2006 08:40:00 4.4 1.9 11.1 0.4 4.3 1.9 10.7 0.4 3.9 1.7 10.3 0.4 294 22 286 165 -3.9 0.2 -3.5 -4.4 11/21/2006 08:50:00 8.4 1.7 12.6 4.6 8.3 1.7 12.6 4.6 6.9 1.7 11.5 3 300 10 294 165 -3.7 0 -3.5 -3.9 11/21/2006 09:00:00 9.6 1.5 13 5.7 9.4 1.4 13 5.7 8.7 1.7 13 4.6 311 8 322 165 -3.9 0 -3.5 -4.2 11/21/2006 09:10:00 8.9 1.5 12.6 4.9 8.7 1.6 13 4.2 6.8 1.5 10.7 3 304 11 309 165 -4.2 0.1 -3.7 -4.4 11/21/2006 09:20:00 9.7 1.7 13.3 4.6 9.6 1.6 13.3 4.6 7.4 1.7 12.6 3.4 301 10 295 165 -4 0 -3.7 -4.4 11/21/2006 09:30:00 10.3 1.3 13.3 6.8 10.2 1.4 13.3 6.1 7.7 1.5 11.8 3.4 304 10 296 165 -3.8 0.1 -3.5 -3.9 11/21/2006 09:40:00 11.5 1.1 14.5 8 11.3 1.1 14.1 8.4 10.1 1.3 13 6.1 312 6 316 165 -3.4 0 -3.3 -3.5 11/21/2006 09:50:00 12.3 1.1 14.9 8 12 1.1 14.5 7.6 11 1.1 13.7 6.1 312 6 292 165 -3.2 0.1 -2.8 -3.5 11/21/2006 10:00:00 11.3 1.6 15.6 7.2 11.1 1.5 15.3 7.2 10.2 1.7 13.7 6.5 313 7 326 165 -2.7 0.2 -2.4 -3 11/21/2006 10:10:00 11.1 1.2 14.1 8 10.9 1.2 14.1 8 9.1 1.5 13 5.3 306 8 314 165 -2.5 0 -2.1 -2.6 11/21/2006 10:20:00 11.6 1.4 15.6 7.6 11.6 1.4 15.3 8 9 1.5 13 4.9 306 9 304 165 -2.1 0.2 -1.7 -2.6 11/21/2006 10:30:00 13.2 1.5 16.8 8.8 13 1.5 16.8 8.4 11.6 1.8 15.3 5.7 311 8 306 165 -1.9 0.1 -1.7 -2.1 11/21/2006 10:40:00 12.9 1.4 16.4 8.8 12.6 1.4 16.1 8.4 11.7 1.5 15.6 6.8 314 7 302 165 -1.9 0 -1.7 -2.1 11/21/2006 10:50:00 11.7 1.5 15.6 6.5 11.5 1.5 15.6 6.5 10.3 1.6 15.3 5.3 313 7 310 165 -1.7 0 -1.4 -1.9 11/21/2006 11:00:00 10.6 1.5 14.9 7.2 10.4 1.5 14.5 6.8 9.5 1.3 13.3 6.5 313 9 305 165 -1.8 0 -1.4 -1.9 11/21/2006 11:10:00 10.1 1.2 13.7 6.8 9.9 1.1 13.3 6.5 8.9 1.1 11.8 6.1 311 9 308 165 -1.8 0 -1.4 -1.9 11/21/2006 11:20:00 7.8 1.4 12.6 4.6 7.7 1.4 12.6 4.6 6.6 1.7 11.5 2.6 320 14 310 165 -1.2 0.3 -0.5 -1.7 11/21/2006 11:30:00 8 1.5 11.8 4.2 7.9 1.5 11.5 3.8 6.7 1.3 10.3 3 316 16 296 165 -0.9 0.1 -0.3 -1.4 11/21/2006 11:40:00 7.4 1.5 11.8 3.4 7.3 1.5 11.8 3.4 6.4 1.6 11.1 2.6 323 13 341 165 -0.5 0.1 -0.1 -1.2 11/21/2006 11:50:00 8.2 1.7 14.1 5.3 8.2 1.7 13.7 4.9 7.3 1.7 13.7 3.4 313 10 295 165 -0.6 0 -0.3 -0.8 11/21/2006 12:00:00 7.4 1.5 13.7 3.8 7.3 1.5 13.3 3.8 6.4 1.3 10.3 3 319 16 291 165 -0.4 0.2 -0.1 -0.8 11/21/2006 12:10:00 6.4 1.5 10.7 2.3 6.3 1.5 10.7 2.6 5.2 1.5 8.8 1.1 321 17 332 165 0.1 0 0.4 -0.1 11/21/2006 12:20:00 6.3 2.3 12.6 0.4 6.2 2.3 11.8 0.4 5.2 2.1 15.3 0.4 323 33 322 165 0.4 0.1 1.1 -0.1 11/21/2006 12:30:00 6.3 1.3 9.9 1.9 6.1 1.5 9.9 1.9 5.6 1.4 9.5 1.5 329 18 333 165 0.2 0 0.7 -0.1 11/21/2006 12:40:00 6.1 1.2 9.5 2.3 5.5 1.1 9.5 2.3 5.3 1.2 8.4 2.6 342 15 341 165 0.3 0 0.9 0.2 11/21/2006 12:50:00 7.6 1.5 12.2 4.6 7.3 1.5 12.2 4.6 6.7 1.4 11.1 3.8 322 15 307 165 0.6 0 1.1 0.2 11/21/2006 13:00:00 8.3 0.9 11.5 5.7 8.2 1 10.7 5.3 7.6 1.1 10.7 4.2 316 9 310 165 0.2 0 0.7 -0.1 11/21/2006 13:10:00 9.7 1.1 13 6.8 9.5 1.1 12.6 6.8 8.5 1.1 11.8 5.7 311 7 305 165 0.1 0 0.4 -0.1 11/21/2006 13:20:00 9.5 1.2 13 6.8 9.3 1.2 12.2 6.8 8.4 1.2 11.5 5.7 314 11 297 165 0.1 0 0.2 -0.1 11/21/2006 13:30:00 11.4 2 17.2 6.8 11.3 1.9 16.8 7.2 9.5 1.5 14.1 6.1 306 9 297 165 -0.2 0.1 0.2 -0.3 11/21/2006 13:40:00 12.2 1.5 16.4 8.4 12 1.5 16.1 8.4 10.9 1.3 15.3 7.6 314 9 297 165 -0.2 0 -0.1 -0.3 11/21/2006 13:50:00 11.9 1.4 16.1 8.8 11.7 1.3 15.6 8 11.1 1.4 15.6 8 317 10 306 165 -0.1 0 0.2 -0.3 11/21/2006 14:00:00 11.9 1.2 16.8 8.4 11.7 1.2 16.8 8.4 10.9 1.5 16.1 6.5 315 9 298 165 -0.3 0.1 0.4 -1 11/21/2006 14:10:00 10.9 1.5 14.9 6.8 10.7 1.5 14.9 6.8 10 1.5 13.3 6.5 312 7 306 165 -0.3 0 -0.1 -0.5 11/21/2006 14:20:00 12.4 1.4 17.6 8.8 12.2 1.4 16.4 8.4 11.2 1.2 14.9 8 313 9 307 165 -0.3 0.1 0.2 -0.8 11/21/2006 14:30:00 12.3 1.4 17.6 9.5 12 1.5 16.8 6.8 11.6 1.5 16.4 8.4 324 13 339 165 -0.3 0.1 0.2 -0.8 11/21/2006 14:40:00 12.1 1.2 15.3 7.6 11.9 1.2 14.9 7.6 11.3 1.3 14.9 6.1 320 9 322 165 -0.4 0 -0.3 -0.5 11/21/2006 14:50:00 13.2 1.5 17.9 9.1 13 1.5 17.2 9.1 12.1 1.5 16.8 8 313 10 300 165 -0.3 0 -0.1 -0.5 11/21/2006 15:00:00 13.7 1.7 19.1 8.4 13.5 1.6 18.7 8.8 12.4 1.5 17.6 8 312 12 320 165 -0.3 0 0.2 -0.5 11/21/2006 15:10:00 13.1 1.8 19.9 8.8 12.9 1.9 19.1 8.8 11.8 1.7 17.6 7.6 311 9 312 165 -0.3 0 -0.1 -0.5 11/21/2006 15:20:00 14.1 1.8 19.5 9.5 14 1.8 19.5 9.1 13.4 1.7 19.1 8.4 320 11 309 165 -0.6 0.1 0.2 -1.2 11/21/2006 15:30:00 14.9 1.4 18.7 11.8 14.7 1.4 18.7 11.8 14.5 1.6 18.7 9.5 323 9 315 165 -0.6 0 -0.3 -0.8 11/21/2006 15:40:00 14.8 2 20.6 10.3 14.6 2 20.6 10.7 13.8 1.9 19.9 9.5 318 11 323 165 -0.8 0.1 -0.5 -1.4 11/21/2006 15:50:00 13.9 1.8 20.2 9.5 13.7 1.8 19.5 9.1 13.3 1.9 18.7 8 320 8 332 165 -0.8 0.1 -0.5 -1.2 11/21/2006 16:00:00 14.4 1.8 19.1 9.5 14.2 1.8 18.7 9.1 13.5 1.8 18.7 8.4 316 10 313 165 -0.8 0 -0.1 -1.2 11/21/2006 16:10:00 15.2 2 20.2 10.7 15 2 20.2 10.7 14.5 2 19.5 9.1 320 11 308 165 -0.7 0 -0.5 -1.2 11/21/2006 16:20:00 16.6 1.8 20.6 12.2 16.4 1.9 21 11.5 15.6 1.8 20.2 10.7 318 10 307 165 -0.6 0 -0.3 -1.2 11/21/2006 16:30:00 16.1 2.4 22.6 10.3 15.8 2.4 22.6 10.3 14.9 2.5 22.1 9.5 313 8 310 165 -0.9 0.1 -0.3 -1.2 11/21/2006 16:40:00 10.7 1.7 15.3 6.5 10.6 1.7 14.5 6.1 9.8 1.7 13.7 5.7 316 10 290 165 -1.2 0.1 -0.8 -1.4 11/21/2006 16:50:00 9.6 1.3 13 6.5 9.3 1.3 13.3 6.1 8.8 1.2 12.6 6.1 333 15 348 165 -1.4 0 -1 -1.4 11/21/2006 17:00:00 11.3 1.9 17.6 7.6 10.5 2.1 18.3 5.3 10.6 2.1 17.2 6.8 343 11 350 165 -1.3 0 -1 -1.4 11/21/2006 17:10:00 12 2.1 19.1 7.6 11.7 2.1 19.9 7.2 10.8 2.1 17.9 5.7 326 17 319 165 -0.9 0.1 -0.5 -1.2 11/21/2006 17:20:00 12 1.8 16.8 7.2 11.8 1.8 16.8 6.8 11.5 1.8 16.8 6.8 329 13 328 165 -0.8 0 -0.3 -1 11/21/2006 17:30:00 13.1 2.1 18.3 7.6 12.9 2.1 18.3 6.8 12.5 2.2 17.9 7.6 318 10 313 165 -0.8 0 -0.5 -0.8 11/21/2006 17:40:00 16.3 1.7 20.2 11.1 16.1 1.7 20.2 11.1 15.6 1.7 19.5 9.9 318 7 318 165 -0.8 0 -0.5 -0.8 11/21/2006 17:50:00 16.2 1.4 19.5 13 16.1 1.4 19.9 13 15.4 1.5 18.7 11.5 315 8 330 165 -0.7 0 -0.3 -0.8 11/21/2006 18:00:00 14.6 1.4 17.9 9.9 14.5 1.4 17.9 9.5 13.4 2.1 17.2 8.4 310 8 310 165 -0.8 0 -0.3 -0.8 11/21/2006 18:10:00 12.6 1.2 16.4 9.1 12.4 1.2 16.1 9.1 11.3 1.4 14.5 7.6 311 7 301 165 -0.8 0.1 -0.3 -1.2 11/21/2006 18:20:00 12.3 1.1 16.4 9.1 12.1 1.1 16.1 9.1 10 1.2 13.3 7.2 305 8 292 165 -1 0 -0.5 -1.2 11/21/2006 18:30:00 11.9 1.2 15.6 8.4 11.6 1.1 15.3 8.4 10.4 1.2 13.7 6.8 308 7 304 165 -1.2 0.1 -0.8 -1.4 11/21/2006 18:40:00 11.9 1.2 14.5 8.8 11.7 1.2 14.5 8.8 10.2 1.1 13 6.8 308 7 303 165 -1.5 0 -1.2 -1.9 11/21/2006 18:50:00 11.6 1.1 14.1 8.8 11.4 1.1 14.1 8.8 10 1.1 13 6.8 309 8 304 165 -1.6 0 -1.2 -1.9 11/21/2006 19:00:00 11.4 1.5 15.3 6.8 11.2 1.4 14.9 7.2 10.6 1.3 14.5 5.3 319 11 302 165 -1.6 0.1 -1.2 -1.9 11/21/2006 19:10:00 9.7 1.3 14.5 7.2 9.6 1.5 14.1 4.9 9.2 1.3 13.3 6.8 337 9 326 165 -1.8 0.1 -1.2 -1.9 11/21/2006 19:20:00 12 2.5 19.5 7.2 11.8 2.5 19.1 6.5 11.1 2.1 18.7 6.8 325 17 293 165 -1.5 0.1 -1.2 -1.9 11/21/2006 19:30:00 13.2 1.5 17.2 9.1 13 1.5 16.8 9.1 11.9 1.5 15.3 8 315 10 298 165 -1.3 0 -0.8 -1.4 11/21/2006 19:40:00 12.4 1.7 16.1 6.8 12.2 1.7 15.6 6.5 11.1 1.8 15.3 6.1 310 9 302 165 -1.2 0 -0.8 -1.4 11/21/2006 19:50:00 11.9 1.5 16.4 8.4 11.7 1.4 16.4 8.8 9.9 1.4 14.1 7.2 306 8 301 165 -1.4 0.1 -0.8 -1.7 11/21/2006 20:00:00 9.7 1.7 15.3 6.1 9.6 1.7 14.9 5.7 8.6 1.4 12.6 5.3 312 11 294 165 -1.5 0 -1.2 -1.9 11/21/2006 20:10:00 12.8 2.2 21.8 7.6 12.6 2.2 21.4 8 11.5 2.1 20.6 6.8 316 11 305 165 -1.8 0.1 -1.4 -2.1 11/21/2006 20:20:00 9.6 1.9 16.4 5.7 9.5 1.9 16.4 5.7 8.6 1.9 15.3 5.3 314 13 304 165 -1.8 0.1 -1.4 -2.1 11/21/2006 20:30:00 11.5 2.9 19.1 6.5 11.4 2.9 19.5 6.5 10 2.8 17.9 3.8 309 13 304 165 -1.7 0.2 -1.2 -1.9 11/21/2006 20:40:00 13.8 2.3 20.2 7.6 13.6 2.3 19.9 8 12.7 2.3 19.9 7.2 316 12 320 165 -1.4 0 -1.2 -1.7 11/21/2006 20:50:00 13.4 2.4 18.7 6.8 13.2 2.3 18.3 7.6 12.1 2.6 18.7 6.1 315 11 310 165 -1.6 0 -1 -1.9 11/21/2006 21:00:00 13.8 1.8 17.6 8.8 13.6 1.7 17.9 8.8 12.4 1.8 16.8 8 315 10 299 165 -1.8 0 -1.4 -1.9 11/21/2006 21:10:00 13.8 1.9 19.5 8.4 13.6 1.8 19.1 8.8 12.5 2.1 17.2 7.6 316 9 319 165 -1.8 0 -1.4 -2.1 11/21/2006 21:20:00 13.6 2 18.7 8 13.3 2 17.9 8 12.3 1.9 18.3 6.8 316 9 305 165 -1.9 0 -1.4 -2.1 11/21/2006 21:30:00 13.8 2.3 19.1 8 13.6 2.3 19.1 7.6 12.6 2.2 17.9 7.2 314 9 307 165 -1.8 0 -1.4 -2.1 11/21/2006 21:40:00 12.3 2.2 19.1 6.8 12.1 2.2 18.3 6.5 10.6 1.9 15.3 6.1 308 12 293 165 -1.6 0 -1.4 -1.9 11/21/2006 21:50:00 10.9 2 15.6 6.1 10.8 1.9 17.2 5.7 9.6 1.9 14.9 5.3 310 13 291 165 -2 0 -1.4 -2.1 11/21/2006 22:00:00 12.2 2.2 18.3 6.1 12.1 2.2 17.9 5.7 11.1 2.2 16.4 5.7 316 12 304 165 -2 0 -1.7 -2.1 11/21/2006 22:10:00 11.7 1.7 16.1 6.8 11.6 1.7 16.1 6.8 10.1 1.7 15.6 6.1 309 10 312 165 -2.2 0 -1.9 -2.4 11/21/2006 22:20:00 11.2 1.9 19.1 6.1 11.1 1.9 18.3 5.7 9.8 1.7 15.6 6.5 310 12 315 165 -2.1 0 -1.9 -2.1 11/21/2006 22:30:00 8.2 1.3 11.1 4.9 8.1 1.2 11.5 4.6 7.3 1 10.3 5.3 316 12 302 165 -2.2 0 -1.7 -2.6 11/21/2006 22:40:00 7.5 1.7 12.2 4.2 7.3 1.6 11.8 4.2 7.1 1.7 12.2 4.2 336 12 344 165 -2.4 0 -1.9 -2.6 11/21/2006 22:50:00 7.9 1.2 11.1 5.3 7.7 1.2 10.7 5.3 7.3 1 9.9 4.6 322 13 310 165 -2.4 0.1 -1.9 -2.8 11/21/2006 23:00:00 9.1 1.3 13.3 6.5 8.9 1.3 13.3 6.5 8.4 1.4 13.3 5.7 317 9 316 165 -2.5 0 -2.1 -2.8 11/21/2006 23:10:00 8.9 1.2 12.6 6.1 8.6 1.3 11.8 3.8 8.5 1.3 11.8 4.6 338 12 331 165 -2.4 0 -2.1 -2.6 11/21/2006 23:20:00 8.9 1.4 13 5.7 8.6 1.5 13.3 5.3 8.4 1.3 12.2 4.9 337 10 336 165 -2.2 0.1 -1.9 -2.6 11/21/2006 23:30:00 7.1 1.1 9.9 3.8 7 1.2 9.5 3.8 6.6 1.1 9.1 3.8 326 11 326 165 -2.2 0 -1.9 -2.6 11/21/2006 23:40:00 9.5 2 14.5 5.7 9.4 2 14.9 5.3 8.6 2.2 14.9 4.6 314 11 317 165 -1.8 0.3 -1.4 -2.4 11/21/2006 23:50:00 9.6 1.4 14.1 6.1 9.5 1.3 13.7 5.3 8 1.3 11.5 4.6 305 10 316 165 -2 0.1 -1.4 -2.1 11/22/2006 00:00:00 8.7 1.7 14.5 4.9 8.6 1.7 13.7 4.9 7.4 1.6 12.2 3.8 311 13 307 165 -2 0.1 -1.7 -2.1 11/22/2006 00:10:00 6.6 1.1 10.7 3.8 6.5 1.1 10.3 3.8 5.9 1 9.1 3.4 317 13 304 165 -2.1 0.2 -1.4 -2.6 11/22/2006 00:20:00 10.7 2 16.1 4.9 10.4 2 15.3 4.6 9.2 1.8 14.5 4.2 305 9 290 165 -2.3 0.1 -1.9 -2.6 11/22/2006 00:30:00 10.2 1.6 14.9 5.7 10.1 1.5 14.5 5.7 9 1.5 13.3 4.6 316 12 310 165 -2.3 0.1 -1.9 -2.6 11/22/2006 00:40:00 6.8 1 9.9 4.2 6.7 1 9.9 4.2 6.2 1.2 9.5 3.8 327 12 326 165 -2.4 0 -2.1 -2.6 11/22/2006 00:50:00 8.5 1.8 13.7 3.4 8.5 1.7 14.1 4.2 6.9 1.7 12.2 3 308 13 301 165 -2.4 0 -2.1 -2.6 11/22/2006 01:00:00 10.2 1.7 15.6 5.7 10.1 1.7 15.3 6.1 8.9 1.9 15.3 4.6 314 10 318 165 -2.2 0.1 -1.9 -2.4 11/22/2006 01:10:00 10.3 1.3 14.9 7.2 10.2 1.3 14.9 7.2 9.1 1.5 12.6 5.7 311 10 300 165 -1.9 0.1 -1.4 -2.1 11/22/2006 01:20:00 11.6 1.9 17.2 6.8 11.5 1.8 16.8 6.5 10.2 1.9 16.1 4.9 310 12 286 165 -1.7 0.1 -1.4 -2.1 11/22/2006 01:30:00 11.8 1.6 15.6 7.6 11.6 1.6 15.3 7.6 10.2 1.6 14.9 6.1 312 9 326 165 -1.8 0.1 -1.2 -2.1 11/22/2006 01:40:00 13.5 1.6 17.6 7.6 13.3 1.5 17.9 7.2 11.9 1.8 16.1 7.6 313 9 310 165 -2 0 -1.7 -2.1 11/22/2006 01:50:00 13.7 1.7 18.7 8.4 13.5 1.7 18.3 8.4 12.2 1.8 17.6 7.2 314 10 307 165 -2 0 -1.7 -2.1 11/22/2006 02:00:00 12.3 1.8 16.8 7.2 12.2 1.8 16.8 6.1 11.1 1.8 16.4 6.5 314 9 310 165 -1.8 0 -1.4 -1.9 11/22/2006 02:10:00 11 1.9 16.1 6.1 10.9 1.8 15.6 6.5 9.9 1.8 13.7 5.7 313 11 307 165 -2 0.1 -1.4 -2.1 11/22/2006 02:20:00 11.5 1.2 14.5 7.6 11.4 1.2 14.1 6.5 10.2 1.5 14.5 6.8 316 9 302 165 -2.1 0 -1.7 -2.1 11/22/2006 02:30:00 12.1 1.4 17.6 7.6 11.9 1.4 16.4 7.2 10.9 1.9 16.1 6.5 317 10 311 165 -2 0 -1.9 -2.1 11/22/2006 02:40:00 12.7 1.7 17.2 8.8 12.6 1.7 17.2 8.4 11 2.2 17.6 5.3 312 11 308 165 -2 0 -1.7 -2.1 11/22/2006 02:50:00 13.7 1.8 19.5 8.8 13.5 1.8 19.5 9.1 12.6 1.9 17.6 7.6 316 10 318 165 -1.7 0 -1.4 -1.9 11/22/2006 03:00:00 13 1.5 17.9 7.6 12.8 1.4 17.6 8.4 11.5 1.5 15.6 7.2 312 8 302 165 -1.9 0.1 -1.4 -2.1 11/22/2006 03:10:00 13.2 1.5 17.2 9.1 13 1.5 17.2 8.4 11.6 1.5 15.6 8 314 9 313 165 -2.1 0 -1.7 -2.4 11/22/2006 03:20:00 12.9 1.6 21 8.4 12.7 1.6 21 9.1 11.6 1.9 19.9 6.8 318 13 309 165 -2 0 -1.7 -2.1 11/22/2006 03:30:00 11.7 1.5 16.1 6.8 11.6 1.4 15.6 6.8 9.9 1.3 14.5 6.8 309 8 302 165 -2.2 0 -1.7 -2.4 11/22/2006 03:40:00 13.8 1.7 17.2 9.9 13.6 1.6 17.2 9.5 10.5 1.6 15.3 7.2 302 6 305 165 -2.2 0 -1.9 -2.4 11/22/2006 03:50:00 15.5 1.7 19.1 10.3 15.3 1.7 18.7 10.3 13.7 1.6 17.2 9.1 312 7 305 165 -2.1 0.1 -1.7 -2.1 11/22/2006 04:00:00 13.5 1.5 17.2 9.9 13.3 1.5 17.2 9.9 12.4 1.3 16.4 8.8 314 7 310 165 -2.2 0 -1.7 -2.6 11/22/2006 04:10:00 15 1.5 19.5 11.5 14.8 1.5 19.1 10.7 13.4 1.4 17.6 8.8 311 6 310 165 -2.2 0 -1.9 -2.4 11/22/2006 04:20:00 13.6 1.2 18.3 10.7 13.4 1.2 17.6 10.7 12.7 1.3 16.4 9.1 314 7 313 165 -2 0 -1.7 -2.4 11/22/2006 04:30:00 13 1.5 16.4 8.4 12.8 1.5 16.4 7.6 12.2 1.7 16.1 7.6 317 11 309 165 -2 0 -1.7 -2.1 11/22/2006 04:40:00 11 1.2 14.9 7.6 10.9 1.2 14.1 8 10 1.6 16.1 6.1 316 10 315 165 -2.1 0 -1.7 -2.4 11/22/2006 04:50:00 12.5 1.5 16.8 8.4 12.3 1.5 16.8 8.4 10.9 1.7 16.4 7.2 311 14 308 165 -2.1 0 -1.9 -2.4 11/22/2006 05:00:00 11.8 1.4 15.3 7.6 11.6 1.3 14.9 7.6 10.3 1.5 14.1 5.7 311 9 297 165 -2.2 0 -1.9 -2.4 11/22/2006 05:10:00 9.9 1.8 16.4 5.7 9.6 2 16.8 4.6 9.5 1.9 16.4 5.7 337 12 339 165 -2.1 0.1 -1.9 -2.4 11/22/2006 05:20:00 8.1 1.9 13.3 4.6 8 1.9 13.7 4.6 7.8 1.8 13.7 4.6 327 12 333 165 -2 0.1 -1.7 -2.4 11/22/2006 05:30:00 5.8 1.1 8.8 3.4 5.4 1.2 8.8 2.3 5.7 1.2 8.8 3 335 15 314 165 -2.4 0 -1.9 -2.6 11/22/2006 05:40:00 5.8 1 9.1 3.4 5.3 1 8 2.3 5.5 1 8.4 3 336 22 356 165 -2.6 0 -2.1 -2.8 11/22/2006 05:50:00 6.8 0.9 9.9 4.2 6.6 1 9.9 3.8 6.3 1 8.8 3.8 320 14 331 165 -2.4 0 -2.1 -2.8 11/22/2006 06:00:00 8.3 1.3 11.8 4.6 7.9 1.4 11.1 4.6 8.2 1.5 11.5 4.2 334 14 358 165 -2.5 0 -2.1 -2.8 11/22/2006 06:10:00 10.8 1.2 14.1 7.2 10.2 1.4 13.7 6.5 10.6 1.3 14.9 6.1 341 10 343 165 -2.3 0 -2.1 -2.6 11/22/2006 06:20:00 11.3 2.3 15.6 6.5 10.7 2.3 15.6 3.8 11 2.3 17.9 6.1 340 10 354 165 -2.1 0 -1.9 -2.1 11/22/2006 06:30:00 7.2 1.7 11.8 2.3 6.8 2 11.5 1.9 6.6 1.7 11.1 1.1 334 20 336 165 -2.1 0 -1.7 -2.4 11/22/2006 06:40:00 12 2.3 17.9 5.7 11.9 2.3 17.9 5.7 11.5 2.3 16.8 5.7 326 11 320 165 -2.2 0 -1.9 -2.4 11/22/2006 06:50:00 12.5 2.5 17.9 6.1 12.4 2.6 17.6 5.3 12.2 2.6 19.1 5.7 334 11 330 165 -2.4 0.1 -1.9 -2.6 11/22/2006 07:00:00 9.3 1.5 13.3 5.3 8.6 1.7 13 3.8 8.7 1.7 13.3 4.6 333 22 326 165 -2.8 0.1 -2.1 -3 11/22/2006 07:10:00 11.8 2 18.3 7.2 11.6 2 18.7 6.5 11.3 1.8 16.4 7.2 324 15 300 165 -3 0.1 -2.6 -3.3 11/22/2006 07:20:00 11.8 2.2 19.1 6.1 11.7 2.1 19.1 6.1 11.6 1.9 18.7 7.2 329 12 316 165 -3.1 0 -2.6 -3.5 11/22/2006 07:30:00 10.9 2.4 18.3 6.5 10.5 2.6 17.9 4.9 10.4 2.4 17.9 5.3 334 17 328 165 -3.4 0 -2.8 -3.5 11/22/2006 07:40:00 12.4 2.4 18.3 6.8 12.1 2.4 19.1 7.2 11.6 2.3 17.9 6.5 333 11 334 165 -3.3 0 -3 -3.5 11/22/2006 07:50:00 10.3 2.4 17.6 4.9 10.1 2.5 17.2 5.3 9.2 2.4 16.4 4.2 333 12 322 165 -3.3 0 -2.8 -3.5 11/22/2006 08:00:00 7.7 2.5 16.1 3.4 7.3 2.5 15.3 3 6.9 2.9 14.5 0.7 358 29 23 165 -3.3 0 -3 -3.5 11/22/2006 08:10:00 10.4 1.8 15.6 5.3 8.8 2 14.9 4.2 10.1 1.9 16.1 5.7 2 16 18 165 -3.1 0 -2.8 -3.3 11/22/2006 08:20:00 9.9 1.9 15.3 4.9 9.2 2.2 15.3 4.2 9.6 2 14.9 4.6 348 15 338 165 -3.3 0 -2.8 -3.5 11/22/2006 08:30:00 10.6 1.8 15.3 5.3 9.3 1.7 14.5 4.2 10.6 1.9 16.1 6.5 353 17 8 165 -3.3 0.1 -3 -3.5 11/22/2006 08:40:00 13.9 2.3 20.6 8.8 13.3 2.8 20.2 6.8 13.7 2.5 21 7.2 338 13 339 165 -3.2 0 -2.8 -3.5 11/22/2006 08:50:00 14.9 1.9 20.6 10.3 14.5 2.1 21 8.8 14.7 1.9 21 9.9 335 12 329 165 -3.2 0 -2.8 -3.5 11/22/2006 09:00:00 19.1 2.5 25.2 12.6 18.8 3.1 24.8 9.1 18.9 2.5 24.8 11.8 339 10 335 165 -3 0 -2.8 -3.3 11/22/2006 09:10:00 20.3 1.8 24.8 14.1 20.3 2.1 24.4 14.1 19.8 1.9 24.4 14.5 341 6 338 165 -3.1 0 -2.8 -3.3 11/22/2006 09:20:00 19.3 1.8 24 14.9 19.2 2 24.8 12.2 18.8 1.9 23.3 13.7 337 7 338 165 -2.9 0 -2.6 -3 11/22/2006 09:30:00 19.4 1.8 25.2 13.7 19.4 2.2 24.4 13.3 18.6 2.2 24 11.5 338 8 337 165 -2.8 0 -2.6 -2.8 11/22/2006 09:40:00 17.8 1.8 21.4 12.2 17.4 2.3 22.6 10.3 17.2 1.9 21.8 11.8 342 8 350 165 -2.5 0 -2.1 -2.8 11/22/2006 09:50:00 16.1 1.8 21.4 12.6 16 1.9 22.1 11.1 15.8 2 21 11.8 342 6 344 165 -2.2 0 -1.9 -2.6 11/22/2006 10:00:00 15.5 1.5 21.8 12.2 15.2 1.5 19.1 9.5 15.5 1.6 21.4 10.7 341 9 354 165 -2 0 -1.7 -2.1 11/22/2006 10:10:00 14.7 1.5 21 10.7 14.1 2 19.9 8 14.5 1.7 19.9 10.3 338 10 353 165 -2 0 -1.7 -2.1 11/22/2006 10:20:00 13.9 2.5 19.9 6.1 13.6 2.5 20.2 6.5 13.5 2.6 19.5 6.5 333 11 334 165 -2 0 -1.7 -2.1 11/22/2006 10:30:00 11.7 2.7 17.9 4.6 11.1 2.8 17.2 3.8 11 2.9 17.6 3 338 13 340 165 -1.5 0.2 -1.2 -1.9 11/22/2006 10:40:00 10.7 2.3 16.4 5.3 10 2.3 15.6 4.6 10.3 2.3 16.1 4.2 342 13 347 165 -1.3 0.1 -1 -1.4 11/22/2006 10:50:00 12.4 1.7 18.7 7.2 11.7 2 16.4 7.2 12 2 19.1 6.8 341 12 358 165 -1.5 0 -1 -1.7 11/22/2006 11:00:00 12 1.8 21.4 8.8 11.5 1.9 18.7 6.8 11.6 1.7 16.8 8 333 15 342 165 -1.6 0 -1.2 -1.9 11/22/2006 11:10:00 14.6 2 19.9 9.1 14.4 2.1 19.9 8.8 14.6 2 18.7 9.1 332 10 340 165 -1.6 0 -1.2 -1.9 11/22/2006 11:20:00 15.7 2.3 21 9.9 15.5 2.4 21.4 9.9 15.4 2.3 21 9.9 335 9 343 165 -1.5 0 -1.2 -1.7 11/22/2006 11:30:00 16.5 1.5 20.6 13 16.3 1.6 20.2 8.8 16.1 1.9 21.8 11.1 331 13 339 165 -1.3 0 -1 -1.4 11/22/2006 11:40:00 16.8 1.9 22.1 12.6 16.5 1.9 21.8 12.2 15.7 2.1 22.6 11.5 316 10 310 165 -1.1 0 -0.8 -1.4 11/22/2006 11:50:00 14.2 2.6 23.7 9.5 13.8 2.7 23.7 8.4 13.1 2.5 23.3 8 320 14 319 165 -0.9 0.1 -0.5 -1.2 11/22/2006 12:00:00 12.1 1.2 15.6 4.6 11.9 1.2 15.3 4.6 11.5 1.2 14.9 6.8 322 13 297 165 -0.8 0.1 -0.5 -1 11/22/2006 12:10:00 14.2 2.3 19.5 9.1 14.1 2.2 19.1 9.5 14.3 2.3 19.5 9.5 331 9 329 165 -0.8 0 -0.5 -1 11/22/2006 12:20:00 14.5 2 19.9 10.7 14.2 2.1 19.5 11.1 14 2.4 20.6 8.4 322 12 329 165 -0.8 0.1 -0.3 -1.4 11/22/2006 12:30:00 13.5 1.3 17.2 10.3 13.3 1.3 16.8 9.9 12.8 1.4 16.4 8 328 14 347 165 -0.6 0.1 -0.3 -1.4 11/22/2006 12:40:00 12.6 1.7 17.6 7.6 12.1 2 17.6 7.2 11.9 1.9 17.2 6.5 336 14 337 165 -0.3 0.1 -0.1 -0.8 11/22/2006 12:50:00 11.2 2 17.6 6.5 10.7 1.8 16.8 6.1 10.3 1.9 17.2 4.9 342 11 343 165 0.1 0.2 0.4 -0.5 11/22/2006 13:00:00 10 1.7 14.9 6.5 9 1.8 14.9 4.2 9.4 1.8 14.1 5.3 345 14 355 165 0.1 0.1 0.4 -0.5 11/22/2006 13:10:00 8.8 1.8 14.1 4.9 8.4 1.9 13.7 4.2 8 1.9 13.3 3.4 334 17 315 165 0.2 0 0.7 0.2 11/22/2006 13:20:00 8.3 1.7 13 3.4 8.2 1.8 13 3.4 6.9 2.2 13 1.5 323 17 343 165 0.5 0 0.9 0.2 11/22/2006 13:30:00 9.1 1.7 13.3 4.9 9.1 1.7 13.7 5.3 8 1.7 12.6 3.8 320 15 326 165 0.2 0 0.7 0.2 11/22/2006 13:40:00 9.2 1.4 13.3 6.1 9.1 1.4 13.7 5.7 8.3 1.5 13 4.9 322 15 344 165 0.2 0 0.7 0.2 11/22/2006 13:50:00 10.6 1.3 14.5 7.6 10.2 1.5 14.1 5.7 10.1 1.3 15.3 6.8 330 14 326 165 0 0 0.4 -0.1 11/22/2006 14:00:00 10.8 1.4 15.6 7.2 10.6 1.4 15.6 6.8 10.3 1.5 14.5 6.5 320 12 314 165 -0.2 0.1 0.2 -0.3 11/22/2006 14:10:00 11 1.6 15.3 6.5 10.8 1.6 14.5 6.5 10.1 1.6 15.6 5.7 314 9 321 165 -0.3 0.1 -0.1 -0.8 11/22/2006 14:20:00 13.2 1.9 18.3 8 13 1.9 17.6 8.4 12.4 2 17.6 7.2 317 10 318 165 -0.3 0 0.2 -0.5 11/22/2006 14:30:00 13.1 1.7 17.2 8.8 12.9 1.7 16.8 8.4 12.4 1.7 16.1 8.4 321 11 323 165 -0.3 0.2 0.2 -1 11/22/2006 14:40:00 9.8 1.7 13.7 6.5 9.7 1.7 13.3 6.5 9.1 1.8 14.9 5.3 326 13 322 165 -0.2 0 0.2 -0.8 11/22/2006 14:50:00 11.6 1.7 17.2 7.6 11.2 1.7 17.6 7.2 11.2 1.9 17.2 6.8 336 11 349 165 -0.2 0.1 0.2 -0.5 11/22/2006 15:00:00 13.5 1.7 17.2 8.8 13.1 1.9 17.6 8.4 12.9 2.1 17.6 7.6 340 9 339 165 -0.2 0.1 -0.1 -0.8 11/22/2006 15:10:00 13.1 1.5 17.2 8.4 12.6 1.8 17.9 7.6 12.9 1.8 17.6 8 338 11 333 165 -0.2 0 -0.1 -0.3 11/22/2006 15:20:00 11.5 1.7 16.4 6.1 10.8 2.1 16.1 5.7 10.9 1.8 16.4 5.3 343 13 340 165 -0.2 0 0.2 -0.3 11/22/2006 15:30:00 9.9 1.5 14.5 6.1 9.7 1.4 13.3 5.7 9.2 1.5 13.3 5.7 333 13 319 165 -0.3 0 -0.1 -0.5 11/22/2006 15:40:00 9.5 1.3 13.7 5.7 9.3 1.3 13.3 6.1 8.7 1.5 13.3 5.3 326 12 332 165 -0.5 0.1 -0.1 -0.8 11/22/2006 15:50:00 9.9 1.3 13.7 6.8 9.7 1.3 13.3 6.5 9.3 1.3 13 6.5 328 10 328 165 -0.7 0.1 -0.3 -1.2 11/22/2006 16:00:00 10.2 1.3 13.3 7.2 10 1.3 13.7 6.8 9.9 1.3 13.7 6.5 334 9 346 165 -0.9 0.2 -0.5 -1.4 11/22/2006 16:10:00 9.4 1.4 13 5.3 9 1.5 12.6 6.1 8.8 1.4 12.2 5.3 337 11 319 165 -1.1 0 -0.8 -1.4 11/22/2006 16:20:00 9 1.4 12.6 5.7 8.6 1.5 13 5.3 8.2 1.4 11.8 4.9 339 12 344 165 -1.3 0.1 -0.8 -1.9 11/22/2006 16:30:00 7.3 0.9 9.1 4.2 7.1 0.9 9.1 4.2 6.7 0.9 8.8 3.4 333 12 331 165 -2 0.1 -1.4 -2.1 11/22/2006 16:40:00 7 1.2 9.9 3.4 6.9 1.2 10.3 3.4 5.8 1.4 9.9 2.6 319 13 344 165 -2 0 -1.9 -2.1 11/22/2006 16:50:00 7.9 0.9 10.7 5.3 7.7 0.9 10.7 5.3 7.2 1 9.5 4.6 326 10 320 165 -2.1 0 -1.7 -2.4 11/22/2006 17:00:00 7.4 0.9 9.9 4.6 7.2 0.9 9.9 4.9 6.8 1 9.9 4.6 327 9 319 165 -2.4 0 -1.9 -2.6 11/22/2006 17:10:00 7.4 1 9.9 4.6 7.3 1 9.5 4.6 6.7 1 9.5 3.4 323 10 304 165 -2.3 0 -1.9 -2.6 11/22/2006 17:20:00 7.8 1.2 11.1 4.9 7.6 1.3 11.1 4.6 6.9 1.2 10.3 4.2 341 8 335 165 -2.4 0.1 -1.9 -2.6 11/22/2006 17:30:00 8.2 0.9 11.1 6.1 7.9 1 10.3 4.6 7.4 1 9.5 4.6 341 8 339 165 -2.4 0 -2.1 -2.6 11/22/2006 17:40:00 6.8 1.1 9.5 4.2 6.6 1.2 9.1 3.8 6.4 1.1 9.1 3.4 338 9 340 165 -2.4 0 -1.9 -2.6 11/22/2006 17:50:00 6.1 1 9.5 3.4 5.8 1.1 9.1 3 5.8 1 8.8 3.4 339 12 339 165 -2.5 0 -2.1 -2.6 11/22/2006 18:00:00 7.2 1 10.7 4.9 7 1.1 9.9 3.4 7 1.1 9.5 4.6 335 9 338 165 -2.5 0.1 -2.1 -2.6 11/22/2006 18:10:00 6.9 0.5 8.8 5.7 6.8 0.6 8.4 4.9 6.7 0.7 10.3 4.9 336 8 319 165 -2.7 0.2 -2.1 -3.3 11/22/2006 18:20:00 7.6 0.7 9.1 4.6 7.4 0.7 9.1 4.2 7.4 0.8 9.1 5.3 333 7 333 165 -3.2 0 -2.8 -3.5 11/22/2006 18:30:00 7.7 1.2 10.7 4.6 7.4 1.3 10.7 3.8 7.3 1.2 10.3 4.2 338 10 331 165 -3.3 0 -3 -3.5 11/22/2006 18:40:00 8.5 1.5 12.6 5.3 8.1 1.5 12.2 4.2 7.7 1.8 12.2 1.9 339 10 332 165 -3.2 0 -2.8 -3.5 11/22/2006 18:50:00 8.7 1.5 11.8 4.9 8.2 1.6 11.1 3.8 7.9 1.5 11.5 4.2 339 10 355 165 -3.2 0 -2.8 -3.3 11/22/2006 19:00:00 9 1.5 11.8 5.3 8.4 1.6 12.6 4.6 8.1 1.7 12.2 3.8 339 11 344 165 -3.3 0 -2.8 -3.5 11/22/2006 19:10:00 8.6 1 10.7 5.7 8.5 1 11.1 5.7 7.8 1 10.3 5.3 334 9 348 165 -3.5 0.1 -3 -3.5 11/22/2006 19:20:00 9 1.1 11.8 4.9 8.8 1.1 11.8 4.9 8.2 1.3 11.1 4.2 329 10 314 165 -3.4 0 -3.3 -3.5 11/22/2006 19:30:00 8.6 1.4 11.1 4.9 8.3 1.4 11.5 4.2 7.6 1.5 10.7 3.4 336 12 323 165 -3.4 0 -3 -3.5 11/22/2006 19:40:00 7.6 1.7 11.5 3.4 7.5 1.7 11.5 3.4 6.9 2.1 11.8 1.9 331 12 339 165 -3.4 0 -3 -3.5 11/22/2006 19:50:00 7.8 1.3 11.1 4.2 7.6 1.4 11.8 4.6 7.1 1.2 10.3 4.2 331 13 346 165 -3.2 0 -2.8 -3.5 11/22/2006 20:00:00 7.7 1.3 10.3 4.2 7.5 1.2 10.3 3.8 7 1.3 10.7 4.2 335 10 349 165 -3.2 0 -2.8 -3.5 11/22/2006 20:10:00 7.3 1.2 9.9 3 6.9 1.3 10.3 3 6.1 1.5 9.5 1.1 340 13 329 165 -3.4 0 -3 -3.5 11/22/2006 20:20:00 7.1 1.1 10.7 4.2 6.9 1.2 10.3 3.4 6.4 1.2 9.1 3.4 335 11 331 165 -3.3 0 -3 -3.5 11/22/2006 20:30:00 7.4 1.3 10.3 4.2 7.1 1.4 9.9 3.8 6.6 1.7 9.9 1.5 338 13 310 165 -3.2 0 -2.8 -3.5 11/22/2006 20:40:00 5.3 1.2 8.4 0.4 4.7 1.2 8.4 0.4 3.9 1.1 6.8 1.1 343 22 329 165 -3.4 0.1 -3 -3.5 11/22/2006 20:50:00 3 1.6 6.5 0.4 2.7 1.6 6.5 0.4 2.2 1.4 6.1 0.4 345 56 336 165 -3.5 0.1 -3 -3.7 11/22/2006 21:00:00 0.8 0.7 3.4 0.4 0.7 0.5 2.3 0.4 0.8 0.4 1.9 0.4 190 90 318 165 -3.5 0 -3.3 -3.5 11/22/2006 21:10:00 1.2 0.8 3 0.4 1 0.7 3 0.4 0.8 0.5 2.6 0.4 287 47 318 165 -3.3 0 -3 -3.5 11/22/2006 21:20:00 2.1 1.1 4.6 0.4 1.9 1.2 4.6 0.4 1.5 0.8 3.8 0.4 318 28 295 165 -3.3 0 -3 -3.5 11/22/2006 21:30:00 2.7 1.1 5.3 0.7 2.6 1.2 5.7 0.4 2.4 1.1 5.3 0.4 320 18 323 165 -3.4 0 -3.3 -3.5 11/22/2006 21:40:00 2.1 1 4.2 0.4 2.1 1 4.2 0.4 1.9 1 4.2 0.4 306 26 340 165 -3.5 0 -3.3 -3.5 11/22/2006 21:50:00 3.9 1.3 8 1.1 3.6 1.2 7.2 0.4 3.4 1.3 7.6 0.4 326 17 359 165 -3.3 0 -3 -3.5 11/22/2006 22:00:00 5 1 8 2.3 4.7 1 7.2 1.9 4.5 1.1 7.2 1.5 340 12 328 165 -3.3 0 -3 -3.5 11/22/2006 22:10:00 5.4 0.8 8 2.6 4.6 1.1 8 2.6 5.1 1 8 2.6 349 12 354 165 -3.3 0 -3 -3.5 11/22/2006 22:20:00 6 1.1 8.8 3.4 5.1 1.1 7.6 1.9 5.5 1 8.4 2.6 348 9 358 165 -3.4 0 -3 -3.5 11/22/2006 22:30:00 5.4 1 8.4 2.6 4.1 1 6.8 1.5 5.3 1 9.1 2.3 3 10 357 165 -3.3 0 -3 -3.5 11/22/2006 22:40:00 5.6 0.8 8 3.8 4.9 1.1 7.6 2.3 5.2 0.9 8 3 360 15 3 165 -3.6 0.1 -3.3 -3.9 11/22/2006 22:50:00 6 0.8 8 3.8 4.7 1.1 7.6 2.3 5.7 0.9 8.4 2.6 3 9 5 165 -3.7 0 -3.3 -3.9 11/22/2006 23:00:00 5.6 0.7 7.2 3.8 4.4 1 6.5 1.9 5.3 0.7 6.8 3.4 4 9 9 165 -3.7 0 -3 -3.9 11/22/2006 23:10:00 5.4 0.8 8 3.8 4.2 1.2 7.6 2.3 4.9 0.8 7.2 3 359 10 351 165 -3.9 0 -3.5 -3.9 11/22/2006 23:20:00 5.4 0.8 7.6 3.4 4.3 1.1 7.6 1.9 5 0.9 6.8 2.6 360 10 0 165 -3.7 0 -3.5 -3.9 11/22/2006 23:30:00 5.8 1.1 9.5 2.3 4.7 1.3 8.4 1.9 5.2 1 8.8 2.3 357 13 355 165 -3.8 0 -3.5 -4.2 11/22/2006 23:40:00 6 1.1 8.8 3.4 5 1.4 8 1.9 5.1 1.1 8 3 352 8 358 165 -4 0.1 -3.5 -4.2 11/22/2006 23:50:00 7.6 1 9.9 4.9 6.5 1.3 9.9 3 6.8 1.1 9.1 3.4 352 6 359 165 -3.9 0.1 -3.5 -4.2 11/23/2006 00:00:00 8 0.8 10.7 5.3 7.4 1.3 10.3 4.2 7.2 0.9 9.5 4.6 348 8 350 165 -3.8 0 -3.5 -3.9 11/23/2006 00:10:00 8.1 1.1 12.2 5.3 7.5 1.5 13.3 4.2 7.5 1.2 11.5 4.6 345 10 340 165 -3.8 0 -3.5 -3.9 11/23/2006 00:20:00 8.7 1 11.8 5.7 8.4 1.2 11.8 4.6 8.2 1 10.7 5.7 342 12 322 165 -3.8 0 -3.5 -3.9 11/23/2006 00:30:00 8.7 1.1 12.2 6.1 8.6 1.2 12.2 5.7 8.2 1.2 11.5 5.7 337 12 341 165 -3.8 0 -3.5 -4.2 11/23/2006 00:40:00 8.8 1.5 13.3 5.7 8.3 1.5 13 4.6 8 1.5 11.5 4.6 339 12 339 165 -3.6 0 -3.5 -3.9 11/23/2006 00:50:00 7.2 1.7 11.8 3.4 6.7 1.7 11.8 2.6 6.7 1.8 11.5 3.4 340 13 355 165 -3.6 0 -3.3 -3.9 11/23/2006 01:00:00 7.7 1.4 12.6 4.2 7.1 1.6 13 3 7.1 1.7 12.2 2.6 342 13 344 165 -3.6 0 -3.3 -3.9 11/23/2006 01:10:00 6.3 1.5 10.3 3 6.2 1.5 10.7 2.6 5.7 1.4 9.1 0.7 328 19 345 165 -3.7 0.1 -3.3 -3.9 11/23/2006 01:20:00 8.2 2.2 14.1 3.4 7.6 1.9 13 3.4 7.5 2 12.6 2.6 346 13 353 165 -3.6 0 -3.3 -3.7 11/23/2006 01:30:00 9.3 1.8 14.9 5.3 8.7 1.5 13.7 4.9 8.8 1.7 13 4.9 344 11 356 165 -3.5 0.1 -3.3 -3.5 11/23/2006 01:40:00 9 1.5 13.7 5.7 8.8 1.5 13.3 4.9 8.6 1.7 12.6 5.3 337 10 344 165 -3.4 0 -3.3 -3.5 11/23/2006 01:50:00 8.6 1.7 14.1 4.9 8.2 1.6 13.7 4.6 8.3 1.8 14.5 4.2 335 15 343 165 -3.3 0.1 -3 -3.5 11/23/2006 02:00:00 7 1.7 11.5 3.4 6.6 1.7 11.5 3.4 6.5 1.5 11.8 3 340 13 343 165 -3.4 0 -2.8 -3.5 11/23/2006 02:10:00 7.3 1.5 12.2 3.4 6.9 1.5 11.5 3 6.7 1.4 10.7 3 335 20 348 165 -3.3 0 -3 -3.5 11/23/2006 02:20:00 6.1 1.3 10.3 2.6 6 1.3 9.5 2.6 5.4 1.3 9.1 1.9 328 14 336 165 -3.3 0.1 -3 -3.5 11/23/2006 02:30:00 6.5 1.2 10.3 3.8 6.2 1.3 9.5 2.6 6.1 1.1 9.1 3.8 338 14 3 165 -3.4 0.1 -2.8 -3.5 11/23/2006 02:40:00 5.3 1.8 10.3 1.5 5.2 1.7 9.9 1.1 4.9 1.7 9.5 1.5 310 29 338 165 -3.1 0 -2.8 -3.3 11/23/2006 02:50:00 7.7 1.8 12.2 3.4 7.6 1.8 12.6 3 7.3 2.2 13.3 2.3 327 13 334 165 -3.2 0 -2.8 -3.5 11/23/2006 03:00:00 7.5 2.1 13 3.4 7.4 2.2 13.3 3.4 7.2 2.1 12.6 2.3 326 22 344 165 -3.2 0.1 -2.8 -3.5 11/23/2006 03:10:00 6.6 2 10.7 1.5 6.5 2 11.1 1.5 6.2 2.1 11.1 0.4 329 21 338 165 -3.4 0 -3 -3.5 11/23/2006 03:20:00 6.8 1.2 10.3 4.2 6.7 1.2 9.9 3.4 6.2 1.3 9.9 3.4 325 17 329 165 -3.2 0 -2.8 -3.5 11/23/2006 03:30:00 7.3 2.1 14.5 3 7.2 2 13.7 3 7 2.3 13.7 3.4 325 18 348 165 -3 0.1 -2.8 -3.3 11/23/2006 03:40:00 8.7 1.3 11.5 5.3 8.5 1.5 11.5 3.8 8 1.4 11.1 3.8 333 12 339 165 -3.2 0 -2.8 -3.5 11/23/2006 03:50:00 6.6 1.8 12.2 3 6.5 1.8 12.2 3 6.1 2 13.3 2.3 326 20 339 165 -3.2 0.2 -2.6 -3.5 11/23/2006 04:00:00 5.8 2.4 11.1 0.7 5.4 2.1 10.3 1.1 5.5 2.1 10.3 0.4 331 30 341 165 -2.9 0.2 -2.4 -3.3 11/23/2006 04:10:00 4.8 2 9.9 2.3 4.8 1.9 9.9 2.3 4.5 2 9.9 2.3 318 21 344 165 -3.2 0.3 -2.6 -3.5 11/23/2006 04:20:00 5.6 2 10.7 1.1 5.3 1.8 9.9 1.5 4.9 2.1 9.9 1.5 321 24 349 165 -3.4 0 -3 -3.5 11/23/2006 04:30:00 4.5 1.7 9.5 1.1 4.4 1.7 9.9 1.1 4.3 1.6 9.1 0.7 326 18 329 165 -3.7 0 -3.3 -3.9 11/23/2006 04:40:00 6.2 1.5 9.9 3.4 5.9 1.4 9.1 3 5.7 1.7 9.9 2.6 335 17 344 165 -3.8 0 -3.5 -3.9 11/23/2006 04:50:00 5.7 1.8 10.3 1.5 5.6 1.8 10.3 1.5 5.3 2 10.7 0.7 329 32 323 165 -3.5 0.1 -3.3 -3.7 11/23/2006 05:00:00 5.1 1.4 8.4 1.9 5 1.4 8.4 1.5 4.9 1.5 8 1.9 328 22 326 165 -3.7 0 -3.5 -3.9 11/23/2006 05:10:00 4.1 0.8 6.8 2.3 4.2 0.8 6.8 2.6 3.7 0.8 6.8 2.3 300 20 311 165 -3.8 0 -3.5 -4.2 11/23/2006 05:20:00 5.3 1.6 9.9 2.3 5.4 1.6 10.3 2.3 5.3 1.8 9.9 2.3 315 24 328 165 -3.9 0.1 -3.5 -4.4 11/23/2006 05:30:00 6.3 1.8 11.8 2.6 6.3 1.7 11.8 2.6 6 1.9 11.8 2.3 319 15 335 165 -3.9 0 -3.5 -4.4 11/23/2006 05:40:00 8.1 1.9 13.3 4.6 7.9 1.8 13.3 4.6 7.7 2 13.7 4.2 327 15 349 165 -3.7 0 -3.5 -3.9 11/23/2006 05:50:00 7.4 1 11.1 5.3 7.3 1 10.7 5.3 7.2 1 9.9 4.6 324 10 332 165 -3.8 0 -3.5 -4.2 11/23/2006 06:00:00 6.6 1.2 9.9 3 6.4 1.1 9.9 3 5.8 1.3 9.9 2.6 313 17 330 165 -3.9 0 -3.5 -4.2 11/23/2006 06:10:00 7.5 1.3 10.7 4.6 7.2 1.3 10.7 3.8 7.2 1.5 10.7 3.4 326 17 338 165 -3.8 0.1 -3.5 -4.2 11/23/2006 06:20:00 5 1.1 7.6 2.3 5 1.1 7.6 1.9 4.6 1.1 7.6 2.3 311 20 344 165 -3.8 0.1 -3.3 -4.2 11/23/2006 06:30:00 4.5 1 6.5 1.1 4.6 1 6.5 1.9 4.3 0.7 6.5 2.3 290 14 302 165 -3.9 0 -3.5 -4.2 11/23/2006 06:40:00 4.4 0.9 6.5 1.5 4.5 0.9 6.5 1.9 3.6 0.8 5.7 1.9 294 13 305 165 -4.1 0.2 -3.5 -4.6 11/23/2006 06:50:00 5.3 1.3 8 1.5 5.3 1.2 8.4 1.5 4.5 1.1 6.8 1.1 296 13 310 165 -4.3 0.1 -3.9 -4.6 11/23/2006 07:00:00 5.8 1.5 8.4 0.4 5.9 1.5 8 0.4 5.1 1.5 9.1 0.4 293 15 285 165 -4.3 0.1 -3.9 -4.6 11/23/2006 07:10:00 5.8 1.3 9.5 2.6 5.9 1.2 9.5 2.6 5.4 1.2 8.8 2.3 290 15 313 165 -4.2 0.1 -3.7 -4.4 11/23/2006 07:20:00 5.8 1 8.8 2.6 5.8 0.9 8.8 2.6 4.9 1.1 8 1.9 294 9 301 165 -4.2 0.1 -3.5 -4.4 11/23/2006 07:30:00 5.6 0.9 8 3 5.6 0.9 8 3 4.9 1 8 2.6 298 14 307 165 -4.2 0.3 -3.5 -4.6 11/23/2006 07:40:00 4.6 1.1 8 1.9 4.7 1.1 8.4 2.3 4.2 1.1 7.6 1.5 305 18 349 165 -3.9 0.1 -3.5 -4.2 11/23/2006 07:50:00 5.1 1 7.2 3 5 0.9 7.2 2.6 4.4 1 7.2 1.9 307 16 306 165 -3.9 0.1 -3.5 -4.2 11/23/2006 08:00:00 4.1 1 6.5 1.5 4.3 1 7.2 2.3 4.1 0.9 6.5 2.3 282 15 282 165 -3.8 0 -3.3 -3.9 11/23/2006 08:10:00 4.7 1.2 7.6 1.1 4.9 1.2 8 1.9 4.3 1.2 7.6 1.5 290 12 286 165 -3.9 0 -3.5 -4.2 11/23/2006 08:20:00 2.8 1.2 5.3 0.4 3 1.1 5.3 0.4 3 1.2 5.3 0.4 294 30 285 165 -3.7 0.1 -3.3 -4.2 11/23/2006 08:30:00 3.8 1.6 7.2 0.4 4 1.6 7.2 0.4 3.7 1.8 7.2 0.4 288 18 284 165 -3.7 0 -3.3 -3.9 11/23/2006 08:40:00 3.9 1.2 6.8 1.1 4.4 1.2 7.6 1.9 4 1.2 7.2 1.5 279 22 273 165 -3.8 0.1 -3.5 -4.2 11/23/2006 08:50:00 4.4 1.3 8 0.4 4.7 1.4 8 1.5 4.9 1.2 8 1.9 286 16 284 165 -3.9 0 -3.7 -4.2 11/23/2006 09:00:00 4.6 0.9 6.5 2.3 4.9 0.9 6.8 2.6 4.8 1 6.8 2.3 282 13 274 165 -4.1 0 -3.9 -4.4 11/23/2006 09:10:00 5.1 1.3 7.6 1.5 5.6 1.1 7.6 1.9 5.4 1.1 8.4 2.6 276 13 272 165 -4.1 0.1 -3.7 -4.4 11/23/2006 09:20:00 4.4 1.2 7.2 1.5 4.7 1.2 7.6 1.9 4.4 1.3 6.8 1.5 291 17 312 165 -4 0.2 -3.7 -4.6 11/23/2006 09:30:00 5 1.2 8.4 1.9 5.4 1.2 8.4 2.3 5.3 1.2 8.4 2.3 281 12 290 165 -3.9 0 -3.5 -4.2 11/23/2006 09:40:00 3.3 1.3 6.5 0.4 3.6 1.2 6.8 1.1 3.7 1.2 6.8 1.1 295 28 323 165 -3.7 0.1 -3.3 -3.9 11/23/2006 09:50:00 4 1.2 6.8 0.4 4.5 1.3 7.6 0.4 4.5 1.3 7.6 1.1 281 22 265 165 -3.6 0.1 -3 -3.9 11/23/2006 10:00:00 4.4 2 9.1 0.4 4.5 1.9 9.1 0.4 4.4 1.6 8 0.7 292 23 287 165 -3.4 0 -3 -3.5 11/23/2006 10:10:00 5.4 1.3 8.4 2.6 5.5 1.3 8.4 2.3 5.3 1.2 8 2.3 286 11 285 165 -3.4 0 -3.3 -3.5 11/23/2006 10:20:00 7.7 1.3 10.3 3 7.7 1.3 10.7 3.4 6.8 1.5 9.9 2.6 291 8 286 165 -3.5 0.1 -3 -3.7 11/23/2006 10:30:00 8.5 1 11.8 5.3 8.6 1 11.8 5.3 8 1.1 10.7 4.6 286 8 288 165 -3.7 0 -3.3 -3.9 11/23/2006 10:40:00 8.8 1.3 11.5 4.6 8.9 1.3 11.8 4.6 7.6 1.6 11.1 3.8 289 8 292 165 -3.6 0 -3.5 -3.9 11/23/2006 10:50:00 8.5 1.3 11.1 4.6 8.5 1.3 11.5 4.2 7.5 1.4 11.1 2.6 289 7 286 165 -3.6 0 -3.3 -3.7 11/23/2006 11:00:00 8.4 1.2 10.7 4.2 8.4 1.2 10.7 4.6 7.6 1.2 10.3 3.4 286 8 290 165 -3.4 0 -3.3 -3.5 11/23/2006 11:10:00 9.1 1.1 11.5 5.7 9.1 1.1 11.5 6.1 7.9 1.5 11.8 3.8 289 6 290 165 -3.3 0 -3 -3.5 11/23/2006 11:20:00 8.8 0.9 10.7 6.1 8.8 0.9 10.7 6.1 7.6 1.5 11.1 4.2 290 6 289 165 -3.3 0 -3 -3.5 11/23/2006 11:30:00 8.7 0.9 10.3 5.3 8.8 0.9 10.3 5.3 7.3 1.1 9.9 4.6 294 9 288 165 -3.2 0 -2.8 -3.5 11/23/2006 11:40:00 7.8 0.7 9.5 5.3 7.9 0.7 9.1 5.3 7 1 9.1 4.6 289 6 288 165 -3.2 0 -2.8 -3.3 11/23/2006 11:50:00 8.3 0.7 10.3 5.7 8.3 0.7 9.9 6.1 6.7 0.9 9.1 4.6 294 5 291 165 -3.1 0.1 -2.8 -3.5 11/23/2006 12:00:00 7.9 0.9 10.3 5.7 7.8 0.9 10.3 5.7 6.2 0.9 8.8 4.2 300 6 298 165 -2.9 0 -2.6 -3.3 11/23/2006 12:10:00 8.4 0.8 11.1 6.1 8.3 0.8 11.1 6.1 6.8 1 9.9 4.6 300 7 294 165 -2.9 0.1 -2.6 -3.3 11/23/2006 12:20:00 9.1 0.8 10.7 5.7 9.1 0.8 11.1 5.7 7.5 1 10.3 5.3 305 10 300 165 -2.8 0.2 -2.6 -3.3 11/23/2006 12:30:00 8.3 1 10.7 5.3 8.3 1 10.3 5.3 7.1 1 9.5 4.9 302 9 291 165 -2.5 0.1 -2.1 -2.8 11/23/2006 12:40:00 6.3 1 9.9 3.8 6.2 1 9.9 4.2 6 0.9 9.1 3.8 318 15 278 165 -2.1 0 -1.9 -2.6 11/23/2006 12:50:00 6.4 0.9 9.5 3.4 6.3 0.9 9.5 4.2 6.2 1 9.5 3.4 330 14 345 165 -1.8 0 -1.4 -2.4 11/23/2006 13:00:00 6.2 1.2 9.5 3.4 6.1 1.2 9.9 3 6 1.3 9.5 3 324 10 313 165 -2 0.1 -1.4 -2.4 11/23/2006 13:10:00 5.6 1.1 8 1.5 5.7 1 8 2.3 5 0.9 7.6 2.3 301 15 291 165 -1.8 0.3 -1.2 -2.6 11/23/2006 13:20:00 6.1 1.3 9.1 2.3 6.1 1.1 9.1 3 5.3 1.1 8.8 2.6 301 16 315 165 -2 0.1 -1.7 -2.4 11/23/2006 13:30:00 5 0.7 6.8 3 5 0.7 6.5 3 4.5 0.8 6.8 2.6 310 12 293 165 -2 0.1 -1.4 -2.1 11/23/2006 13:40:00 6 1.1 8.8 3.4 5.8 1.1 8.8 3.8 5.8 1.2 8.4 3 321 12 290 165 -1.7 0 -1.4 -1.9 11/23/2006 13:50:00 7.2 1.2 9.1 4.2 7.2 1.2 9.5 3.8 6.1 1 9.5 3.4 303 15 297 165 -1.9 0.2 -1.4 -2.1 11/23/2006 14:00:00 7.1 1 10.7 4.6 6.9 1 10.7 4.6 6.3 0.8 8.4 4.2 310 9 301 165 -2 0.1 -1.7 -2.4 11/23/2006 14:10:00 7.3 0.8 9.5 4.6 7.1 0.8 9.1 4.6 7.2 0.8 9.1 5.3 322 8 328 165 -1.8 0 -1.4 -2.4 11/23/2006 14:20:00 6.7 0.9 8.8 4.6 6.5 0.8 8.4 4.6 5.9 1 8.8 3.4 309 9 307 165 -1.8 0 -1.4 -2.4 11/23/2006 14:30:00 7.5 1 9.5 5.3 7.4 1 9.5 4.9 6 1 9.1 3.8 299 7 292 165 -2.2 0.1 -1.4 -2.6 11/23/2006 14:40:00 7.7 0.9 10.3 4.9 7.7 0.9 9.9 4.9 6.7 1.1 9.5 3.4 295 8 292 165 -2.5 0.1 -2.1 -2.8 11/23/2006 14:50:00 7.7 0.7 9.1 4.9 7.7 0.7 9.1 5.3 6.3 0.9 8.8 4.2 301 8 299 165 -2.5 0.1 -2.1 -3.3 11/23/2006 15:00:00 6.8 0.7 8.4 3.8 6.9 0.7 8.4 3.8 6.2 1.1 8.4 3.8 289 9 278 165 -2.5 0.1 -2.1 -3 11/23/2006 15:10:00 7.6 0.8 9.5 4.9 7.6 0.8 9.5 5.3 6.5 1 9.1 4.2 291 7 288 165 -2.6 0.1 -2.4 -3 11/23/2006 15:20:00 6.4 0.9 9.5 4.6 6.4 0.9 9.1 4.2 5.5 1.1 8.4 3 292 8 278 165 -2.5 0.2 -2.1 -3.3 11/23/2006 15:30:00 6 0.7 7.6 4.2 6 0.7 7.6 4.6 5 0.8 7.2 3.4 302 10 299 165 -2.5 0.1 -2.1 -3.3 11/23/2006 15:40:00 5.4 0.7 6.8 3.8 5.5 0.7 7.2 3.4 4.9 0.7 6.8 3 305 14 298 165 -2.6 0.2 -2.1 -3 11/23/2006 15:50:00 6 0.7 8 3.8 6 0.7 7.6 4.2 5.7 0.8 8 3.8 319 10 310 165 -2.6 0.2 -2.1 -3.3 11/23/2006 16:00:00 6.2 0.9 8.8 4.6 6.2 0.9 8.8 4.2 6.2 1 8.8 4.6 337 11 345 165 -2.5 0.1 -2.1 -2.8 11/23/2006 16:10:00 6.3 0.6 8 4.9 6.1 0.8 8 3.4 6.5 0.6 8 4.9 345 8 2 165 -2.5 0 -2.4 -2.8 11/23/2006 16:20:00 5.3 0.5 6.5 3.8 5.3 0.5 6.5 3.8 5.5 0.5 6.5 3.8 334 8 332 165 -3.2 0.3 -2.6 -3.5 11/23/2006 16:30:00 4.4 0.8 5.7 2.3 4.5 0.8 6.1 3 4.4 0.8 6.1 2.6 320 12 335 165 -3.5 0 -3.3 -3.7 11/23/2006 16:40:00 5.3 0.6 6.5 3.8 5.3 0.6 6.5 3.4 5 0.6 6.5 3.8 315 8 316 165 -3.9 0 -3.3 -4.2 11/23/2006 16:50:00 5.1 0.5 6.5 3.8 5.2 0.5 6.5 3.8 4.5 0.5 6.1 3 306 8 305 165 -3.7 0 -3.3 -3.9 11/23/2006 17:00:00 4.9 0.8 6.5 3 5 0.8 6.5 3 4.5 0.6 6.1 2.3 314 11 310 165 -3.9 0.1 -3.3 -4.4 11/23/2006 17:10:00 5.4 0.7 6.8 3 5.4 0.7 6.8 3.4 4.8 0.7 6.5 2.3 312 10 295 165 -4.1 0 -3.7 -4.4 11/23/2006 17:20:00 5 0.8 7.2 2.3 5 0.8 7.2 2.6 4.7 0.8 6.8 2.3 313 10 300 165 -3.9 0.1 -3.3 -4.2 11/23/2006 17:30:00 4.4 0.8 7.2 2.3 4.5 0.7 6.8 3 4 0.6 5.7 2.3 311 12 290 165 -3.8 0.1 -3.3 -4.2 11/23/2006 17:40:00 5.7 0.8 8 3 5.8 0.8 8 3.4 4.7 0.8 6.8 3 301 8 302 165 -4.2 0.1 -3.7 -4.4 11/23/2006 17:50:00 6.5 0.9 8.8 3.4 6.6 0.8 8.8 4.6 5.4 0.9 7.6 3 305 9 306 165 -3.8 0.2 -3.5 -4.2 11/23/2006 18:00:00 7.8 0.6 9.9 6.1 7.8 0.6 9.5 6.1 6.2 0.8 8.8 4.2 298 6 297 165 -3.7 0 -3.3 -3.9 11/23/2006 18:10:00 8.1 1 10.3 5.7 8.1 1 10.3 5.7 6.6 1 9.5 4.2 300 8 297 165 -3.7 0 -3.3 -3.9 11/23/2006 18:20:00 8.4 0.8 10.7 6.1 8.4 0.8 10.7 6.1 6.9 1 9.1 4.6 299 9 291 165 -3.7 0 -3.5 -3.9 11/23/2006 18:30:00 8.8 0.6 10.3 6.8 8.8 0.6 10.3 7.2 6.7 1 9.1 4.9 299 5 295 165 -3.8 0 -3.5 -3.9 11/23/2006 18:40:00 9.1 0.8 12.2 6.5 9.1 0.8 11.8 6.5 7.1 1.1 10.7 4.9 298 5 287 165 -3.8 0 -3.5 -3.9 11/23/2006 18:50:00 8.9 0.8 10.7 6.5 8.9 0.8 10.7 6.1 6.8 0.7 9.1 4.9 303 5 302 165 -3.8 0 -3.3 -4.2 11/23/2006 19:00:00 8.8 0.9 10.7 6.8 8.8 0.9 11.1 6.8 6.6 0.9 9.1 4.9 300 5 304 165 -3.9 0 -3.5 -4.2 11/23/2006 19:10:00 9 0.7 10.7 7.2 9 0.7 11.1 7.2 6.7 0.8 9.1 4.6 301 5 305 165 -3.9 0 -3.5 -4.2 11/23/2006 19:20:00 8.8 0.8 11.5 6.8 8.8 0.8 11.5 6.8 6.8 1 9.5 4.6 300 7 303 165 -3.8 0 -3.5 -3.9 11/23/2006 19:30:00 8.2 1.2 10.7 3.4 8.2 1.1 10.3 3.4 6.5 1.1 10.3 2.6 297 8 291 165 -3.9 0 -3.5 -4.2 11/23/2006 19:40:00 7.8 1 10.7 4.9 7.7 0.9 10.3 4.6 6 0.9 9.1 3.8 299 6 299 165 -4 0.1 -3.5 -4.4 11/23/2006 19:50:00 7.5 0.9 10.3 4.9 7.5 0.9 9.9 4.9 5.7 1 8.4 3.4 299 8 293 165 -3.8 0 -3.5 -3.9 11/23/2006 20:00:00 7.3 1 9.1 4.6 7.2 1 9.1 4.6 6.4 1 8.8 4.2 309 7 313 165 -3.8 0 -3.5 -4.2 11/23/2006 20:10:00 5.7 0.6 7.2 3.8 5.6 0.6 6.8 3.8 5.2 0.7 6.8 3.4 314 11 301 165 -4.3 0 -3.7 -4.4 11/23/2006 20:20:00 6 0.8 7.6 4.2 5.9 0.7 7.6 3.8 5.4 0.9 7.6 3.4 312 9 308 165 -4.4 0 -3.9 -4.6 11/23/2006 20:30:00 4.5 0.8 7.2 2.6 4.5 0.8 7.6 2.6 4.1 0.9 6.8 2.3 312 13 340 165 -4 0.1 -3.7 -4.4 11/23/2006 20:40:00 5.8 1.2 8 3.4 5.7 1.2 8 3.4 5.1 0.9 8 3 311 9 300 165 -4.2 0.1 -3.9 -4.6 11/23/2006 20:50:00 5.9 0.7 8.4 4.2 5.9 0.7 8 4.2 5.6 0.6 6.8 3.8 314 9 302 165 -4.4 0.1 -3.9 -4.6 11/23/2006 21:00:00 6.5 1 8.4 3.4 6.5 1 8.4 3.8 5.5 0.8 8 3.4 308 11 304 165 -4.2 0.1 -3.5 -4.6 11/23/2006 21:10:00 4.6 1.4 8 2.3 4.7 1.4 8.4 2.3 3.6 1.3 6.8 1.5 305 12 291 165 -4.5 0.1 -3.9 -4.6 11/23/2006 21:20:00 5.4 1.4 8.4 1.9 5.4 1.3 8.4 2.3 4.5 1 7.2 1.5 307 12 284 165 -4.4 0 -4.4 -4.6 11/23/2006 21:30:00 6.4 0.9 8.8 4.2 6.4 0.8 9.1 4.2 5 0.8 7.2 3.4 298 7 301 165 -4.2 0 -3.9 -4.4 11/23/2006 21:40:00 7.4 0.7 9.9 5.3 7.4 0.6 9.5 5.7 6 0.8 8.8 4.2 300 8 290 165 -3.8 0.1 -3.5 -4.2 11/23/2006 21:50:00 6.8 1.2 9.1 3.4 6.7 1.1 9.1 3 5.4 0.9 8.4 2.6 304 8 293 165 -3.8 0.1 -3.5 -4.2 11/23/2006 22:00:00 6.7 0.8 8.4 4.9 6.6 0.7 8.4 4.9 5.4 0.8 7.6 3.8 304 7 294 165 -3.9 0.1 -3.5 -4.4 11/23/2006 22:10:00 6.5 0.8 8.8 4.2 6.5 0.8 8.8 4.6 5.3 1 8 3.4 295 7 298 165 -4.1 0.1 -3.7 -4.4 11/23/2006 22:20:00 8.6 1.1 11.1 5.7 8.6 1.1 11.5 5.3 6.6 1.1 9.5 4.2 302 8 303 165 -3.9 0 -3.5 -4.2 11/23/2006 22:30:00 10.2 0.6 11.5 8.8 10.3 0.6 11.8 9.1 7.2 0.8 9.5 5.3 303 4 298 165 -3.9 0 -3.5 -4.2 11/23/2006 22:40:00 10.4 0.6 12.2 8.8 10.4 0.6 11.8 8.8 8.9 1.1 11.5 6.1 310 4 305 165 -3.9 0 -3.5 -4.2 11/23/2006 22:50:00 9.9 0.7 11.5 7.2 9.9 0.8 11.5 6.8 9.2 0.8 11.1 6.8 312 4 312 165 -3.9 0 -3.5 -4.2 11/23/2006 23:00:00 9.4 0.6 10.7 7.6 9.3 0.6 10.7 7.6 8.6 0.8 10.3 6.5 312 6 308 165 -3.9 0 -3.5 -4.2 11/23/2006 23:10:00 8 1.4 11.1 3.8 7.8 1.4 10.7 3.8 7 1.3 11.1 3.8 310 10 319 165 -4 0.1 -3.5 -4.4 11/23/2006 23:20:00 9 1 11.5 5.7 8.9 1 11.5 5.3 7 0.8 9.9 4.6 304 6 295 165 -4.2 0 -3.7 -4.4 11/23/2006 23:30:00 9.7 0.9 12.6 7.6 9.6 0.9 12.2 7.6 6.8 0.8 9.5 5.3 300 4 300 165 -4.1 0 -3.7 -4.4 11/23/2006 23:40:00 10.5 0.8 12.6 8.4 10.5 0.8 12.2 8.4 7.7 0.8 10.3 5.3 304 4 302 165 -4 0 -3.7 -4.2 11/23/2006 23:50:00 10.1 0.7 11.8 7.6 10.1 0.8 11.5 7.2 7.9 0.8 10.3 5.7 306 5 305 165 -4 0 -3.7 -4.2 11/24/2006 00:00:00 9.4 1 11.1 6.1 9.4 1 11.5 6.5 7.7 0.9 9.9 5.3 307 7 306 165 -3.8 0 -3.5 -3.9 11/24/2006 00:10:00 7.6 1.2 11.1 4.9 7.6 1.2 10.7 4.9 6.5 1 9.9 3.8 306 10 307 165 -3.7 0 -3.5 -3.9 11/24/2006 00:20:00 8 1 10.3 4.9 7.9 1 10.3 4.6 6.8 0.9 9.9 4.6 305 9 292 165 -3.5 0 -3.3 -3.5 11/24/2006 00:30:00 8.4 1.3 11.5 5.3 8.3 1.3 11.1 5.7 6.8 1 10.3 4.6 299 9 289 165 -3.6 0.1 -3.3 -3.9 11/24/2006 00:40:00 8.5 1 10.7 5.7 8.5 0.9 10.7 5.7 6.8 0.9 9.5 4.6 297 6 289 165 -3.7 0 -3.5 -3.9 11/24/2006 00:50:00 7.8 0.7 9.9 6.1 7.8 0.7 9.9 6.1 6.5 1 9.5 4.6 297 7 293 165 -3.7 0 -3.5 -3.9 11/24/2006 01:00:00 8.7 1.2 11.5 6.5 8.7 1.3 11.5 6.1 6.9 1.1 9.9 4.2 296 6 294 165 -3.6 0 -3.3 -3.9 11/24/2006 01:10:00 8.4 1.2 10.7 5.3 8.4 1.2 11.1 5.3 6.8 1.3 9.9 4.2 296 8 297 165 -3.7 0 -3.5 -3.9 11/24/2006 01:20:00 7.6 1.4 10.7 3.8 7.6 1.4 10.7 3.8 6.1 1 8.4 3.8 300 7 304 165 -3.7 0.1 -3.5 -3.9 11/24/2006 01:30:00 5.9 0.8 8 3.8 5.9 0.8 8 3.4 5.2 0.9 8 3 301 11 310 165 -3.7 0 -3.3 -3.9 11/24/2006 01:40:00 7.3 1 9.1 4.2 7.2 1 9.5 3.8 5.9 1 8.4 3.4 298 7 319 165 -3.7 0 -3.5 -3.9 11/24/2006 01:50:00 8.1 0.8 10.3 6.5 8.1 0.8 10.3 6.1 6.2 0.8 8.8 4.2 299 6 297 165 -3.8 0 -3.5 -3.9 11/24/2006 02:00:00 7.3 1.1 9.5 3.8 7.2 1.2 9.5 3.4 6 0.8 8 3 299 8 304 165 -3.8 0 -3.5 -3.9 11/24/2006 02:10:00 6.1 1 8.8 3.8 6.1 1 8.8 3.8 5.3 0.9 8 3 299 13 291 165 -3.7 0 -3.3 -3.9 11/24/2006 02:20:00 5.1 1 7.2 2.3 5.2 1 7.2 2.3 4.7 0.8 7.2 2.3 302 12 302 165 -3.6 0.1 -3.3 -3.9 11/24/2006 02:30:00 3.8 1 6.8 1.1 3.9 1 7.2 1.5 3.7 0.9 6.8 1.9 307 15 293 165 -3.7 0 -3.3 -3.9 11/24/2006 02:40:00 4.2 0.7 6.1 2.3 4.3 0.7 6.5 2.6 4.1 0.7 6.1 2.6 308 12 309 165 -3.6 0.1 -3.3 -3.9 11/24/2006 02:50:00 4.8 0.8 6.8 2.6 4.9 0.8 6.8 3 4.5 0.8 6.8 2.3 301 11 295 165 -3.8 0.1 -3.5 -4.2 11/24/2006 03:00:00 4.3 0.7 6.1 2.6 4.4 0.6 5.7 2.6 4.3 0.7 6.1 1.9 309 16 320 165 -3.8 0.2 -3.3 -4.4 11/24/2006 03:10:00 4.2 0.8 6.5 1.5 4.3 0.8 6.8 2.3 4.1 0.8 6.8 2.3 319 15 340 165 -3.7 0.1 -3.3 -4.2 11/24/2006 03:20:00 4.3 0.9 6.5 2.3 4.4 0.8 6.8 2.3 4.2 0.9 6.8 2.3 316 16 344 165 -4 0.1 -3.7 -4.4 11/24/2006 03:30:00 4.8 0.7 6.5 2.3 4.9 0.7 6.5 2.3 4.4 0.8 6.5 2.3 309 15 313 165 -3.8 0 -3.5 -4.2 11/24/2006 03:40:00 3.7 0.8 6.1 2.3 3.8 0.8 6.5 2.3 3.5 0.9 6.8 1.5 318 21 346 165 -4 0.2 -3.5 -4.4 11/24/2006 03:50:00 3.3 1 4.9 0.4 3.5 0.9 5.3 0.4 3.4 0.7 5.3 1.1 321 19 313 165 -3.7 0 -3.3 -3.9 11/24/2006 04:00:00 4.3 0.6 6.1 2.3 4.4 0.6 5.7 2.3 4.1 0.7 5.7 2.6 302 11 336 165 -3.9 0 -3.3 -4.2 11/24/2006 04:10:00 3.7 0.7 5.7 2.3 3.8 0.7 5.7 1.9 3.7 0.7 6.1 1.9 321 16 339 165 -3.9 0.1 -3.5 -4.2 11/24/2006 04:20:00 3.5 0.7 4.9 1.5 3.7 0.7 4.9 1.9 3.4 0.5 4.9 2.3 317 15 300 165 -4.1 0.2 -3.5 -4.4 11/24/2006 04:30:00 3.7 0.6 5.3 1.9 3.7 0.6 5.3 1.9 3.5 0.6 5.7 1.9 326 16 294 165 -4 0 -3.7 -4.4 11/24/2006 04:40:00 3.5 0.6 5.3 1.1 3.6 0.6 5.7 1.9 3.5 0.6 5.7 2.3 324 15 339 165 -4.1 0 -3.7 -4.4 11/24/2006 04:50:00 3.1 0.8 5.3 1.5 3.3 0.7 5.3 1.9 3.4 0.7 5.3 1.5 306 17 333 165 -4.2 0.1 -3.9 -4.6 11/24/2006 05:00:00 3.9 0.8 5.7 1.9 3.9 0.8 6.1 1.9 4 0.7 6.1 2.6 340 10 336 165 -3.9 0.2 -3.5 -4.4 11/24/2006 05:10:00 2.9 1.1 5.7 0.4 2.9 1.2 5.7 0.4 3.3 1.1 5.3 1.1 342 12 342 165 -3.8 0.1 -3.5 -3.9 11/24/2006 05:20:00 3.3 0.6 4.6 1.5 3.3 0.5 4.6 1.9 3.6 0.5 4.6 1.9 343 8 341 165 -3.9 0 -3.5 -4.2 11/24/2006 05:30:00 3.1 1 5.7 1.5 3.2 1 5.7 1.1 3.2 0.8 5.7 1.9 337 11 332 165 -3.9 0.1 -3.5 -4.2 11/24/2006 05:40:00 2.4 0.6 4.2 1.1 2.7 0.5 4.2 1.5 2.7 0.5 4.2 1.5 323 17 344 165 -3.7 0 -3.5 -3.9 11/24/2006 05:50:00 2.5 0.5 4.2 1.5 2.6 0.5 4.2 1.5 2.5 0.4 3.8 1.1 305 11 283 165 -3.8 0 -3.5 -3.9 11/24/2006 06:00:00 2.9 0.3 3.4 1.9 3 0.3 3.4 2.3 2.8 0.4 3.8 1.9 302 8 308 165 -3.6 0 -3.3 -3.7 11/24/2006 06:10:00 3 0.4 4.2 1.9 3.2 0.4 4.6 2.3 2.9 0.6 4.6 1.5 296 6 294 165 -3.5 0 -3.3 -3.5 11/24/2006 06:20:00 2.5 0.5 4.2 1.1 2.7 0.5 4.2 1.5 2.5 0.5 3.8 1.5 296 7 291 165 -3.4 0 -3 -3.5 11/24/2006 06:30:00 2.7 0.4 3.8 1.9 2.9 0.4 3.8 1.9 2.7 0.6 3.8 1.1 293 7 305 165 -3.5 0.1 -3 -3.9 11/24/2006 06:40:00 2.8 0.5 3.8 1.5 2.9 0.5 3.8 1.5 2.7 0.5 4.2 1.5 293 5 300 165 -3.7 0.1 -3.5 -3.9 11/24/2006 06:50:00 2.4 0.6 3.8 0.7 2.5 0.6 3.8 0.7 2.5 0.6 4.2 1.1 300 7 283 165 -3.8 0 -3.5 -3.9 11/24/2006 07:00:00 0.8 0.6 2.6 0.4 0.8 0.6 2.6 0.4 1.4 0.4 2.6 0.7 299 5 291 165 -3.6 0 -3.3 -3.9 11/24/2006 07:10:00 0.7 0.5 2.3 0.4 0.7 0.5 2.3 0.4 1 0.6 3 0.4 289 10 277 165 -3.3 0 -3 -3.5 11/24/2006 07:20:00 1.2 0.5 2.6 0.4 1.1 0.5 2.6 0.4 1.7 0.5 3.4 0.7 307 12 286 165 -3.5 0 -3.3 -3.5 11/24/2006 07:30:00 0.5 0.2 1.1 0.4 0.4 0.1 1.1 0.4 0.9 0.5 1.9 0.4 278 51 305 165 -3.3 0.1 -3 -3.5 11/24/2006 07:40:00 0.9 0.5 2.3 0.4 0.9 0.5 2.3 0.4 1.2 0.5 2.6 0.4 264 47 289 165 -3.1 0 -2.8 -3.5 11/24/2006 07:50:00 0.7 0.4 1.9 0.4 0.8 0.5 1.9 0.4 1.2 0.4 2.3 0.4 311 4 303 165 -3.4 0.1 -3 -3.7 11/24/2006 08:00:00 0.6 0.4 1.5 0.4 0.7 0.5 1.9 0.4 1.3 0.4 1.9 0.4 280 22 311 165 -3.6 0.2 -3.3 -3.9 11/24/2006 08:10:00 0.6 0.3 1.5 0.4 0.7 0.4 1.5 0.4 1.3 0.3 1.9 0.4 308 11 299 165 -3.4 0 -3 -3.5 11/24/2006 08:20:00 0.4 0.1 1.1 0.4 0.4 0.1 1.1 0.4 1 0.3 1.5 0.4 310 0 310 165 -3.8 0 -3.3 -4.2 11/24/2006 08:30:00 0.4 0 0.7 0.4 0.4 0 0.7 0.4 0.6 0.4 1.9 0.4 310 0 310 165 -3.7 0.2 -3.3 -4.2 11/24/2006 08:40:00 0.4 0.2 1.5 0.4 0.4 0.2 1.5 0.4 0.7 0.5 1.9 0.4 310 0 310 165 -3.8 0.1 -3.3 -3.9 11/24/2006 08:50:00 1.1 0.5 2.3 0.4 1.1 0.5 2.3 0.4 1.6 0.4 2.3 0.7 300 10 293 165 -3.7 0 -3.5 -3.9 11/24/2006 09:00:00 0.4 0.1 0.7 0.4 0.4 0 0.7 0.4 0.7 0.4 1.9 0.4 290 13 302 165 -3.4 0 -3 -3.5 11/24/2006 09:10:00 0.4 0.1 1.1 0.4 0.4 0.1 1.1 0.4 0.7 0.3 1.5 0.4 279 14 300 165 -3.1 0 -2.8 -3.3 11/24/2006 09:20:00 1.2 0.4 1.9 0.4 1.1 0.5 1.9 0.4 1.7 0.3 2.6 0.7 332 13 318 165 -3.3 0 -3 -3.5 11/24/2006 09:30:00 0.4 0 0.4 0.4 0.4 0 0.7 0.4 1 0.2 1.5 0.4 343 0 165 165 -3.5 0.1 -3.3 -3.5 11/24/2006 09:40:00 0.4 0.1 0.7 0.4 0.4 0 0.7 0.4 1 0.2 1.5 0.7 354 9 0 165 -3.4 0 -3.3 -3.5 11/24/2006 09:50:00 0.7 0.3 1.5 0.4 0.5 0.2 1.5 0.4 1.5 0.3 1.9 0.7 8 0 8 165 -3.4 0 -3.3 -3.5 11/24/2006 10:00:00 0.5 0.2 1.1 0.4 0.5 0.2 1.1 0.4 1.3 0.2 1.9 1.1 9 1 8 165 -3.3 0 -3 -3.5 11/24/2006 10:10:00 0.4 0.1 0.7 0.4 0.4 0.2 1.1 0.4 1 0.2 1.5 0.4 31 17 36 165 -3 0 -2.6 -3.3 11/24/2006 10:20:00 0.4 0.1 1.1 0.4 0.4 0.1 1.1 0.4 0.8 0.2 1.5 0.4 57 8 78 165 -2.5 0.1 -2.1 -2.8 11/24/2006 10:30:00 0.4 0 0.4 0.4 0.4 0.1 1.1 0.4 0.8 0.2 1.5 0.4 78 0 165 165 -2.1 0 -1.9 -2.4 11/24/2006 10:40:00 0.4 0.1 1.1 0.4 0.4 0 0.7 0.4 0.8 0.3 1.9 0.4 74 9 52 165 -1.7 0.2 -1.2 -2.1 11/24/2006 10:50:00 0.5 0.3 1.1 0.4 0.5 0.2 1.1 0.4 1.1 0.3 1.9 0.4 45 1 52 165 -0.2 0.6 0.9 -1.2 11/24/2006 11:00:00 1 0.5 2.3 0.4 0.9 0.4 1.9 0.4 1.3 0.5 2.3 0.4 58 22 74 165 1 0.3 1.6 0.4 11/24/2006 11:10:00 1.7 0.7 3.8 0.4 1.4 0.7 3.8 0.4 1.9 0.5 3.8 0.7 63 28 65 165 -0.2 0.2 0.7 -0.5 11/24/2006 11:20:00 1.9 0.5 3 0.7 1.7 0.5 3 0.4 2.1 0.4 3.4 1.1 86 51 116 165 -0.3 0.4 0.9 -0.8 11/24/2006 11:30:00 1.8 0.6 3.4 0.4 1.8 0.6 3.4 0.4 2 0.5 3.8 0.4 152 19 165 165 0.7 0 1.1 0.7 11/24/2006 11:40:00 1.6 0.8 3 0.4 1.6 0.8 3.4 0.4 2 0.7 3.4 0.4 158 17 167 165 0.7 0.1 1.4 0.2 11/24/2006 11:50:00 1.4 0.6 3 0.4 1.5 0.6 3 0.4 1.8 0.6 3 0.4 157 12 161 165 0.7 0.3 1.6 0.2 11/24/2006 12:00:00 1.7 0.9 3.4 0.4 1.8 0.8 3.4 0.4 2 0.7 3.4 0.4 158 17 169 165 1.2 0.2 1.8 0.9 11/24/2006 12:10:00 1.2 0.8 3.4 0.4 1.1 0.8 3.4 0.4 1.4 0.7 3.4 0.4 150 35 164 165 1.1 0.1 1.4 0.9 11/24/2006 12:20:00 1.2 0.7 2.6 0.4 1.2 0.6 2.6 0.4 1.2 0.6 2.6 0.4 135 56 140 165 1.7 0.3 2.3 1.1 11/24/2006 12:30:00 2 0.7 3.8 0.4 2 0.7 3.8 0.4 2.1 0.7 3.8 0.4 130 20 122 165 2 0.2 2.3 1.4 11/24/2006 12:40:00 1.9 0.7 3.4 0.4 1.9 0.8 3.8 0.4 1.9 0.7 3.8 0.4 126 20 137 165 1.3 0 1.6 1.1 11/24/2006 12:50:00 1.8 0.6 3 0.4 1.7 0.6 3 0.4 1.6 0.6 2.6 0.4 136 23 112 165 0.9 0.2 1.4 0.7 11/24/2006 13:00:00 1.7 0.6 3.4 0.4 1.7 0.6 3.4 0.4 1.7 0.5 3 0.7 145 22 147 165 0.5 0.4 1.4 -0.3 11/24/2006 13:10:00 1.2 0.7 2.6 0.4 1.2 0.7 2.3 0.4 1.4 0.8 3 0.4 154 21 135 165 -0.9 0.4 -0.1 -1.4 11/24/2006 13:20:00 0.6 0.3 1.5 0.4 0.7 0.3 1.5 0.4 0.5 0.2 1.5 0.4 90 11 93 165 -1.4 0 -1.2 -1.4 11/24/2006 13:30:00 1.7 0.5 2.6 0.7 1.8 0.5 3 0.7 1.5 0.5 2.6 0.4 75 11 88 165 -1.4 0 -1.4 -1.7 11/24/2006 13:40:00 2 0.4 3 1.1 2.1 0.4 3 1.1 1.9 0.4 2.6 1.1 72 16 84 165 -1.7 0.1 -1.4 -2.1 11/24/2006 13:50:00 2.1 0.4 3.4 1.1 2.1 0.5 3.4 1.1 2.1 0.3 3 1.5 59 12 61 165 -1.9 0 -1.4 -2.1 11/24/2006 14:00:00 2.8 0.2 3.4 2.3 3 0.2 3.4 2.3 2.9 0.3 3.4 1.9 79 3 73 165 -1.6 0.1 -1.2 -1.9 11/24/2006 14:10:00 2.6 0.4 3.4 1.1 2.9 0.4 3.8 1.5 3 0.3 3.8 2.3 79 7 83 165 -1.3 0.1 -0.8 -1.4 11/24/2006 14:20:00 1.6 0.5 2.6 0.4 1.9 0.6 3 0.4 2.1 0.5 3 1.1 77 12 58 165 -1.3 0 -0.8 -1.4 11/24/2006 14:30:00 3.3 0.6 4.6 1.5 3.6 0.6 4.6 1.9 3.2 0.5 4.2 1.9 78 8 79 165 -1.2 0 -1 -1.4 11/24/2006 14:40:00 3.3 0.5 4.2 1.9 3.6 0.5 4.6 1.9 3.1 0.6 4.6 1.9 87 13 94 165 -1.2 0.1 -0.8 -1.4 11/24/2006 14:50:00 3 0.7 4.6 1.1 3.3 0.7 4.6 1.1 3.1 0.6 4.6 1.5 97 8 102 165 -0.6 0 -0.5 -0.8 11/24/2006 15:00:00 2.8 0.5 3.8 1.5 3.1 0.5 4.2 1.9 2.8 0.4 4.2 1.9 94 8 95 165 -0.6 0 -0.5 -0.8 11/24/2006 15:10:00 3.2 0.4 4.2 1.9 3.4 0.4 4.2 2.3 3.2 0.4 3.8 1.9 102 4 106 165 -0.6 0 -0.5 -0.8 11/24/2006 15:20:00 3.4 0.3 4.2 2.6 3.6 0.3 4.2 3 3.4 0.3 4.2 2.6 110 4 115 165 -0.6 0 -0.3 -0.8 11/24/2006 15:30:00 2.9 0.4 3.8 1.9 3.2 0.3 4.2 2.3 3.1 0.3 3.8 1.9 103 5 88 165 -0.5 0 -0.1 -0.8 11/24/2006 15:40:00 3.2 0.2 3.8 2.6 3.4 0.2 4.2 2.6 3.3 0.3 4.2 2.3 100 6 102 165 -0.5 0 -0.3 -1.2 11/24/2006 15:50:00 3 0.6 3.8 1.5 3.3 0.6 4.2 1.5 3.1 0.5 4.2 1.5 87 5 90 165 -0.5 0 -0.3 -0.8 11/24/2006 16:00:00 3.9 0.4 4.6 2.3 4.2 0.4 4.9 2.6 3.9 0.6 4.9 2.3 90 4 97 165 -0.6 0 -0.3 -0.8 11/24/2006 16:10:00 4.2 0.3 4.9 3 4.4 0.3 5.3 3 4.1 0.4 4.9 3 86 3 87 165 -0.5 0 -0.3 -0.8 11/24/2006 16:20:00 4.8 0.4 5.7 4.2 5.1 0.4 6.1 4.2 4.8 0.4 5.7 3.8 88 4 96 165 -0.5 0.2 -0.3 -1 11/24/2006 16:30:00 5.3 0.6 6.8 3.8 5.5 0.6 6.8 3.8 5.2 0.6 6.8 3.8 93 6 102 165 -0.4 0.2 -0.1 -1 11/24/2006 16:40:00 5.5 0.9 7.6 3.8 5.7 0.9 7.6 3.8 5.4 0.9 7.2 3.4 88 6 89 165 -0.3 0.1 -0.1 -1 11/24/2006 16:50:00 6.7 0.9 8.8 4.6 6.8 0.9 8.8 4.2 6.3 0.8 8.8 4.6 90 7 91 165 -0.4 0.1 -0.1 -1.2 11/24/2006 17:00:00 7.3 0.7 8.8 4.9 7.4 0.7 9.1 4.9 7 0.8 8.8 4.2 99 7 96 165 -0.4 0 -0.1 -1 11/24/2006 17:10:00 7.5 0.8 9.5 5.7 7.6 0.9 9.9 5.7 7 1 9.5 4.6 107 6 109 165 -0.5 0.1 -0.1 -1 11/24/2006 17:20:00 8.1 0.7 9.9 6.5 8.3 0.7 9.9 6.5 7.6 0.8 9.5 5.7 111 6 112 165 -0.4 0.1 -0.1 -1 11/24/2006 17:30:00 8.3 0.9 10.3 5.7 8.5 0.9 10.7 5.7 7.7 1 10.3 4.9 112 6 105 165 -0.4 0.1 0.2 -0.8 11/24/2006 17:40:00 8.8 0.8 10.7 6.1 9 0.9 11.1 6.1 8.2 0.9 10.3 5.7 113 6 109 165 -0.4 0.2 -0.1 -0.8 11/24/2006 17:50:00 8.1 1 10.3 5.3 8.2 1 10.7 5.3 7.5 1 9.9 4.2 113 6 105 165 -0.4 0.2 0.2 -0.8 11/24/2006 18:00:00 8.8 1.1 11.1 4.9 9 1.2 11.5 4.6 8.3 1.3 11.5 4.9 109 7 108 165 -0.3 0 -0.1 -0.5 11/24/2006 18:10:00 8.1 0.8 9.9 5.3 8.3 0.8 9.9 5.7 7.8 0.9 9.5 4.9 108 7 104 165 -0.3 0.1 0.2 -0.8 11/24/2006 18:20:00 7.9 1.2 9.9 4.6 8 1.2 9.9 4.2 7.5 1.1 9.5 3.8 115 6 115 165 -0.3 0.1 -0.1 -0.8 11/24/2006 18:30:00 7.2 0.7 9.1 4.2 7.4 0.7 9.1 4.2 6.9 0.7 8.8 4.9 117 6 111 165 -0.3 0.1 -0.1 -0.8 11/24/2006 18:40:00 7.3 0.5 8.4 5.7 7.5 0.5 8.8 6.1 7.2 0.7 8.8 4.9 120 6 121 165 -0.3 0 -0.1 -0.8 11/24/2006 18:50:00 6.6 0.8 9.1 4.6 6.7 0.8 9.1 4.9 6.5 0.8 8.8 4.2 120 4 123 165 -0.2 0 0.2 -0.5 11/24/2006 19:00:00 6.4 0.9 8.4 3.8 6.7 0.9 8.8 4.2 6.2 0.9 8 3.4 115 5 113 165 -0.2 0 0.4 -0.5 11/24/2006 19:10:00 6.8 0.6 8.4 4.6 7 0.6 8.4 4.6 6.6 0.7 8 4.2 112 5 115 165 -0.1 0 0.2 -0.5 11/24/2006 19:20:00 7.8 0.7 9.1 5.7 8 0.7 9.5 5.3 7.5 1 9.1 4.9 115 4 111 165 0.1 0 0.4 -0.3 11/24/2006 19:30:00 7.1 0.6 8.4 4.6 7.3 0.6 8.8 4.9 7 0.7 8.8 4.9 117 5 116 165 0.1 0 0.4 -0.3 11/24/2006 19:40:00 8.3 1 12.2 5.7 8.4 1 11.8 6.1 8.1 1 11.1 5.3 120 6 118 165 0.2 0.1 0.7 -0.1 11/24/2006 19:50:00 8.3 0.9 10.7 5.3 8.5 1 10.7 6.1 8.1 0.9 9.9 6.1 115 6 114 165 0.2 0.1 0.4 -0.3 11/24/2006 20:00:00 9.4 1 12.2 5.7 9.6 1 12.6 5.7 9 1.2 12.2 6.1 115 6 114 165 0.3 0 0.7 -0.3 11/24/2006 20:10:00 9.5 0.9 11.5 7.2 9.8 0.9 11.8 7.2 9.2 1 11.5 6.1 117 5 110 165 0.3 0 0.7 0.2 11/24/2006 20:20:00 9.9 1.1 12.6 6.5 10.1 1.1 12.6 6.5 9.4 1.2 12.2 6.1 113 6 108 165 0.3 0 0.7 0.2 11/24/2006 20:30:00 10.6 0.8 12.6 8.4 10.8 0.9 13 7.6 10 1 12.2 7.6 110 5 108 165 0.3 0 0.7 0.2 11/24/2006 20:40:00 9.8 0.9 12.2 6.8 10.1 1 12.6 6.8 9.4 1 11.8 6.8 108 5 99 165 0.3 0 0.7 0.2 11/24/2006 20:50:00 10.3 1.1 12.6 6.8 10.6 1.1 13 6.8 9.8 1.2 12.2 6.8 107 5 102 165 0.3 0 0.7 0.2 11/24/2006 21:00:00 8.4 1.3 11.8 4.9 8.5 1.4 12.2 4.9 7.8 1.3 11.8 4.6 111 7 106 165 0.3 0 0.7 0.2 11/24/2006 21:10:00 10.3 1.2 12.6 6.8 10.5 1.2 13 6.8 9.8 1.2 12.2 5.7 109 6 105 165 0.5 0 0.7 0.2 11/24/2006 21:20:00 10.4 1.2 12.6 6.8 10.6 1.2 13 7.6 10 1.3 13 6.5 108 5 106 165 0.5 0 0.9 0.4 11/24/2006 21:30:00 9.5 1.1 11.8 6.1 9.7 1.1 12.2 6.5 9.1 1.2 11.8 6.5 108 6 107 165 0.5 0 0.9 0.4 11/24/2006 21:40:00 9.2 1.3 12.6 4.6 9.3 1.3 12.6 4.9 8.5 1.2 12.6 4.9 110 8 108 165 0.6 0 0.9 0.4 11/24/2006 21:50:00 9.8 1 12.6 6.5 10 1.1 12.6 6.5 9.3 1.1 12.6 6.8 99 7 113 165 -0.1 0.3 0.9 -0.5 11/24/2006 22:00:00 9.1 0.7 10.3 6.1 9.3 0.7 10.7 6.5 8.7 0.8 10.3 5.3 94 7 99 165 -0.3 0 -0.1 -0.5 11/24/2006 22:10:00 9.4 0.8 11.1 7.2 9.6 0.8 11.1 7.2 8.9 0.8 10.7 6.5 91 8 98 165 -0.2 0 0.2 -0.3 11/24/2006 22:20:00 9.7 1.1 12.6 6.5 9.9 1.2 12.6 5.7 9.3 1.2 13 5.7 105 6 110 165 0.1 0 0.4 -0.1 11/24/2006 22:30:00 11.6 1 14.1 9.5 11.8 1 14.5 9.5 11.4 1.1 14.5 8.4 116 8 102 165 0.2 0 0.7 -0.1 11/24/2006 22:40:00 11.2 1.1 13.7 8.4 11.3 1.1 13.7 8.4 10.8 1.2 13.7 7.2 121 6 113 165 -0.1 0.1 0.2 -0.3 11/24/2006 22:50:00 10.6 1.1 13.3 7.6 10.7 1.1 13.7 7.2 10.1 1.2 13.7 7.2 118 5 120 165 -0.2 0 -0.1 -0.5 11/24/2006 23:00:00 10.4 0.7 12.2 8 10.6 0.7 12.6 8.4 9.7 0.8 11.8 7.2 111 5 112 165 0.1 0 0.2 -0.1 11/24/2006 23:10:00 11.1 1.4 14.5 7.6 11.3 1.4 14.9 7.2 10.6 1.5 14.1 7.2 111 8 105 165 0.2 0 0.4 -0.1 11/24/2006 23:20:00 12.2 1 14.5 9.5 12.4 1 14.5 9.5 11.6 1.2 14.5 8.4 109 5 104 165 -0.2 0 0.2 -0.3 11/24/2006 23:30:00 11.7 0.9 13.7 8.8 11.8 0.9 14.1 8.4 11 1.1 13.7 7.2 110 6 108 165 -0.3 0 -0.1 -0.5 11/24/2006 23:40:00 12.2 1.2 16.1 8.8 12.4 1.2 16.1 8.8 11.8 1.4 15.3 8 119 6 128 165 -0.3 0 -0.1 -0.5 11/24/2006 23:50:00 8 1.6 11.5 3.8 8 1.6 11.5 4.2 7.8 1.7 11.1 4.9 123 9 126 165 -0.6 0.1 -0.3 -0.8 11/25/2006 00:00:00 9.1 1.2 11.5 4.9 9.3 1.2 11.5 5.3 8.6 1.2 11.5 5.3 106 5 105 165 0.1 0.1 0.2 -0.3 11/25/2006 00:10:00 11 1.2 14.9 7.2 11.2 1.2 14.9 7.6 10.4 1.3 13.7 6.8 110 6 114 165 0.2 0 0.2 -0.1 11/25/2006 00:20:00 12.5 1.1 14.5 9.1 12.7 1.2 14.9 9.1 11.7 1.3 14.5 8.8 106 6 99 165 0.1 0 0.2 -0.1 11/25/2006 00:30:00 12 1.2 14.5 8 12.3 1.3 15.3 8 11.4 1.3 14.1 7.6 106 6 105 165 0 0 0.2 -0.1 11/25/2006 00:40:00 11.5 1.3 14.5 6.5 11.7 1.3 14.9 6.5 10.7 1.3 13.7 6.5 102 7 102 165 -0.1 0 -0.1 -0.3 11/25/2006 00:50:00 11.8 1.1 14.5 8 12 1.1 14.5 8 11 1.3 13.3 7.6 102 6 101 165 -0.3 0.1 -0.1 -0.5 11/25/2006 01:00:00 11.6 0.9 13.7 8 11.8 0.9 13.7 7.6 10.8 1.1 13 8 103 5 101 165 -0.3 0 -0.1 -0.5 11/25/2006 01:10:00 11 1.2 13 6.5 11.2 1.2 13.3 5.7 10.4 1.3 13 5.7 106 7 100 165 -0.2 0 0.2 -0.3 11/25/2006 01:20:00 10.6 1.2 13.3 6.8 10.8 1.2 13.7 6.8 9.9 1.2 13.3 6.5 104 6 108 165 0.1 0 0.2 -0.1 11/25/2006 01:30:00 11.6 0.9 13.7 8.8 11.7 0.9 13.7 9.1 10.7 1 13.7 7.6 107 5 97 165 0 0 0.2 -0.1 11/25/2006 01:40:00 11.7 1.2 14.5 7.6 11.9 1.2 14.9 8 11 1.3 14.1 6.8 109 7 107 165 0 0 0.2 -0.1 11/25/2006 01:50:00 10.8 1.2 13 7.6 11 1.2 13.3 7.6 10.2 1.2 13 7.6 105 6 102 165 -0.1 0 0.2 -0.3 11/25/2006 02:00:00 11.5 1.5 14.9 6.8 11.7 1.5 14.9 6.8 10.9 1.5 13.7 6.5 104 6 112 165 -0.1 0.1 0.2 -0.3 11/25/2006 02:10:00 11.4 1.7 14.5 7.2 11.5 1.7 14.9 6.8 10.5 1.6 13.7 6.5 102 8 107 165 -0.3 0 -0.1 -0.3 11/25/2006 02:20:00 10.3 1.3 14.1 7.6 10.4 1.3 14.5 7.6 9.6 1.3 13.3 6.1 104 6 100 165 -0.3 0 -0.1 -0.5 11/25/2006 02:30:00 11.6 1.2 14.1 8 11.7 1.2 14.1 8 10.8 1.4 14.1 7.2 105 5 103 165 -0.3 0 -0.1 -0.5 11/25/2006 02:40:00 11 1.7 14.5 8 11.2 1.7 14.5 7.6 10.4 1.6 13.3 6.8 104 5 107 165 -0.5 0 -0.3 -0.8 11/25/2006 02:50:00 8.6 0.7 10.3 6.8 8.6 0.8 10.3 6.5 8.2 0.8 9.9 5.7 118 6 118 165 -0.8 0 -0.5 -0.8 11/25/2006 03:00:00 8.1 1.2 10.7 4.9 8.1 1.2 10.7 4.9 8.1 1 10.7 5.3 132 9 125 165 -0.6 0 -0.3 -0.8 11/25/2006 03:10:00 6.3 1 8.8 3.8 6.3 1 8.8 4.2 6.4 1 8.8 4.2 136 9 148 165 -0.5 0 -0.3 -0.8 11/25/2006 03:20:00 5.7 1.5 8.8 2.6 5.8 1.4 8.8 3 5.7 1.4 8.8 1.9 126 22 85 165 -0.4 0 -0.3 -0.5 11/25/2006 03:30:00 9.9 2.1 13.3 4.2 10.1 2.3 14.1 4.2 9.6 2 13.7 4.6 91 10 85 165 -0.3 0 -0.1 -0.5 11/25/2006 03:40:00 11.3 1.3 14.5 7.2 11.6 1.4 14.9 7.6 11 1.3 14.1 6.8 85 7 89 165 -0.2 0 0.2 -0.3 11/25/2006 03:50:00 11.5 1.2 14.9 8 11.8 1.3 14.9 8 11 1.3 14.5 7.6 85 6 87 165 0.1 0.1 0.2 -0.1 11/25/2006 04:00:00 11.7 1.4 14.9 8 11.9 1.5 14.9 8 11.1 1.5 14.5 7.2 88 8 84 165 0.2 0 0.4 -0.1 11/25/2006 04:10:00 11.1 1.3 14.5 7.6 11.4 1.4 15.3 7.6 10.8 1.3 14.9 7.6 83 7 87 165 0.1 0 0.2 -0.1 11/25/2006 04:20:00 11.3 1.4 14.1 7.6 11.6 1.5 14.5 7.6 10.7 1.5 13.7 6.5 86 7 68 165 0.1 0 0.2 -0.1 11/25/2006 04:30:00 9.6 1.3 13.3 6.5 9.8 1.3 13.3 6.5 9.2 1.2 12.2 6.5 95 9 96 165 0 0 0.2 -0.1 11/25/2006 04:40:00 9.4 1.5 13 5.7 9.5 1.7 13.3 5.7 9.1 1.3 13.3 6.5 75 9 80 165 -0.1 0 0.2 -0.1 11/25/2006 04:50:00 9.6 1.4 12.6 5.3 9.8 1.5 13 5.7 9.4 1.3 12.6 6.5 75 7 81 165 0.1 0.1 0.2 -0.1 11/25/2006 05:00:00 8.7 1.3 12.6 5.3 8.9 1.5 12.6 5.7 8.5 1.2 11.8 5.7 76 10 83 165 0.2 0 0.7 0.2 11/25/2006 05:10:00 10.7 1.3 13.7 7.2 10.9 1.3 14.1 6.8 10.2 1.2 13.3 6.8 86 7 85 165 0.4 0 0.7 0.2 11/25/2006 05:20:00 9.7 1.4 12.6 6.5 9.8 1.5 13.3 6.1 9.2 1.3 13.3 6.1 87 8 101 165 0.4 0 0.7 0.2 11/25/2006 05:30:00 10.2 1.5 13.3 6.5 10.4 1.5 13.3 6.8 9.8 1.5 13.3 6.5 93 7 93 165 0.5 0 0.7 0.4 11/25/2006 05:40:00 10.3 1.7 14.1 5.7 10.4 1.7 14.1 5.7 9.5 1.7 13.7 6.1 107 9 108 165 0.5 0.2 0.9 0.2 11/25/2006 05:50:00 9.9 1.4 13.3 6.1 10 1.5 13.3 5.7 9.2 1.4 13 6.1 105 8 105 165 0.4 0 0.7 0.2 11/25/2006 06:00:00 10.8 1.3 13.3 7.2 11 1.4 13.7 6.5 9.9 1.3 12.6 5.7 97 7 103 165 0.5 0 0.9 0.2 11/25/2006 06:10:00 10.4 1.3 13 6.8 10.7 1.3 13.3 6.8 10 1.3 13 6.5 87 7 87 165 0.5 0 0.9 0.4 11/25/2006 06:20:00 10.3 1.7 14.1 5.7 10.5 1.7 14.9 5.3 9.9 1.5 13.3 5.7 89 8 84 165 0.7 0 0.9 0.4 11/25/2006 06:30:00 11.1 1.4 14.9 7.2 11.4 1.5 14.9 7.2 10.3 1.4 14.1 6.8 94 8 95 165 0.5 0 0.9 0.4 11/25/2006 06:40:00 11.1 1.5 14.1 6.8 11.3 1.7 14.5 6.5 10.5 1.5 13.7 6.5 91 8 88 165 0.5 0 0.7 0.2 11/25/2006 06:50:00 10.6 1.2 13 6.8 10.8 1.3 13 6.8 10 1.2 13 6.8 89 7 91 165 0.5 0 0.7 0.2 11/25/2006 07:00:00 10.5 1.3 13.7 6.5 10.7 1.5 14.1 6.1 10 1.5 13.7 6.1 88 7 86 165 0.5 0 0.9 0.2 11/25/2006 07:10:00 10.8 1.3 13.7 7.2 10.8 1.4 13.7 7.2 9.7 1.3 13 6.5 94 9 85 165 0.5 0 0.7 0.4 11/25/2006 07:20:00 7.8 1.6 11.1 4.2 7.6 1.7 11.5 3.8 7.1 1.6 10.3 3.4 103 14 106 165 0.4 0 0.7 0.2 11/25/2006 07:30:00 6.9 2 11.1 2.3 6.9 2 11.5 2.6 6.7 1.9 11.1 1.9 114 15 97 165 0.5 0 0.9 0.4 11/25/2006 07:40:00 5.8 2.6 12.2 1.5 6 2.5 12.6 1.5 5.7 2.5 11.8 1.9 133 10 136 165 0.4 0.1 0.7 0.2 11/25/2006 07:50:00 10.5 1.4 13.7 5.7 10.6 1.5 14.1 5.3 10.2 1.5 13.7 5.3 122 7 119 165 0.5 0 0.7 0.4 11/25/2006 08:00:00 11.3 0.9 13.3 8.8 11.5 1 13.7 8.8 11.1 1 13.7 7.6 123 5 123 165 0.4 0.1 0.7 0.2 11/25/2006 08:10:00 9.1 0.9 11.5 6.5 9.2 1 11.8 6.5 8.7 1 11.1 6.1 118 6 124 165 0.2 0 0.4 0.2 11/25/2006 08:20:00 9.6 0.8 12.2 7.2 9.8 0.8 11.8 7.2 9 1 11.8 6.5 113 4 107 165 0.2 0 0.7 0.2 11/25/2006 08:30:00 8.7 0.7 11.5 7.2 8.7 0.8 11.5 6.8 8.4 0.7 9.9 6.1 119 5 117 165 0.2 0 0.4 0.2 11/25/2006 08:40:00 9 0.8 10.7 6.8 9.1 0.8 10.7 6.8 8.8 0.9 11.5 6.5 123 6 126 165 0.2 0 0.2 0.2 11/25/2006 08:50:00 9 0.9 11.5 7.2 9.1 0.9 11.5 6.5 8.8 0.9 11.1 6.5 123 6 124 165 0.2 0 0.7 0.2 11/25/2006 09:00:00 8.4 1 10.7 4.9 8.5 1.1 10.7 5.3 8.3 1.2 11.1 4.9 123 6 114 165 0.3 0 0.7 0.2 11/25/2006 09:10:00 8.9 0.8 11.1 6.1 9 0.8 11.5 6.1 8.7 1 11.1 5.7 125 6 130 165 0.3 0 0.7 0.2 11/25/2006 09:20:00 9.3 1.4 13 6.8 9.4 1.3 13 6.8 9.2 1.4 13.3 6.1 126 6 134 165 0.4 0 0.7 0.2 11/25/2006 09:30:00 9.2 1.1 12.2 6.5 9.3 1.1 12.2 6.5 8.9 1.2 11.5 5.7 124 6 130 165 0.5 0 0.7 0.2 11/25/2006 09:40:00 9.7 1.1 12.6 7.2 9.7 1.1 12.6 7.2 9.4 1.2 13.3 6.8 124 6 122 165 0.6 0 0.9 0.4 11/25/2006 09:50:00 9.6 1 12.6 6.8 9.7 1 13.3 6.8 9.5 1 11.8 6.1 127 6 132 165 0.6 0 0.9 0.4 11/25/2006 10:00:00 8.4 1.2 11.8 5.3 8.5 1.2 11.8 4.9 8 1.2 12.2 4.6 120 6 112 165 0.5 0 0.9 0.2 11/25/2006 10:10:00 8.9 1.1 12.2 6.5 9 1.1 12.2 6.5 8.7 1.1 11.5 6.1 123 6 122 165 0.5 0 0.7 0.2 11/25/2006 10:20:00 8.6 1.3 11.5 6.1 8.5 1.4 11.8 6.1 8.4 1.4 11.8 5.3 122 5 119 165 0.5 0 0.9 0.4 11/25/2006 10:30:00 8.6 1.3 11.8 5.7 8.5 1.4 11.8 5.3 8.4 1.4 12.2 5.3 125 8 116 165 0.9 0 1.4 0.7 11/25/2006 10:40:00 7.7 1.4 11.5 4.6 7.8 1.3 11.8 4.6 7.5 1.3 11.1 4.2 123 8 126 165 0.9 0 1.4 0.9 11/25/2006 10:50:00 9.9 1 12.6 7.2 10 1 12.6 6.8 9.5 1 12.2 6.5 123 6 118 165 0.9 0 1.4 0.9 11/25/2006 11:00:00 8.2 1 10.7 5.7 8.2 1 10.7 4.9 8 1.1 10.3 5.7 126 7 131 165 0.8 0 1.4 0.7 11/25/2006 11:10:00 8.5 0.9 10.7 6.1 8.6 0.9 10.7 5.7 8.5 0.9 10.7 6.5 125 6 132 165 0.9 0 1.4 0.7 11/25/2006 11:20:00 8.5 0.9 10.3 6.1 8.5 1 10.3 6.1 8.3 1 10.3 6.1 124 5 119 165 0.9 0 1.4 0.9 11/25/2006 11:30:00 7.9 0.7 9.5 5.7 7.9 0.7 9.9 5.3 7.8 0.7 9.9 5.3 125 6 121 165 1.4 0.2 1.8 0.9 11/25/2006 11:40:00 7.5 0.8 9.5 4.9 7.5 0.8 9.5 5.3 7.4 0.8 9.5 4.9 126 7 134 165 1.5 0.2 1.8 1.4 11/25/2006 11:50:00 7.6 0.7 9.1 5.7 7.7 0.7 9.1 5.3 7.6 0.7 9.1 5.7 126 6 126 165 1.5 0 1.8 1.4 11/25/2006 12:00:00 7.3 0.7 9.1 4.6 7.4 0.7 9.1 5.7 7.3 0.9 9.5 4.9 123 7 116 165 1.8 0 1.8 1.6 11/25/2006 12:10:00 7.5 0.6 8.8 5.7 7.5 0.7 9.1 5.7 7.4 0.7 9.1 5.7 126 5 115 165 1.9 0.1 2.3 1.4 11/25/2006 12:20:00 6.6 0.5 7.6 4.6 6.6 0.5 7.6 4.9 6.7 0.6 8 4.9 129 6 126 165 2 0.1 2.3 1.4 11/25/2006 12:30:00 6.6 0.6 8 5.3 6.7 0.6 8 5.3 6.6 0.6 8.4 4.9 126 6 122 165 2 0.1 2.3 1.4 11/25/2006 12:40:00 7.2 0.5 8.8 5.7 7.3 0.5 8.4 6.1 7.2 0.6 8.8 5.3 131 5 128 165 2 0 2.3 1.8 11/25/2006 12:50:00 5.9 1.1 8.8 4.2 5.9 1.1 8.8 4.2 5.9 1 8.4 3.8 137 6 135 165 2.3 0.1 2.8 1.8 11/25/2006 13:00:00 4.8 0.5 6.1 3.4 4.8 0.5 6.1 3.4 5 0.5 6.1 3.8 140 8 130 165 2.6 0 2.8 2.3 11/25/2006 13:10:00 5.3 0.4 6.5 3.8 5.2 0.4 6.1 3.8 5.5 0.5 6.8 4.2 143 8 162 165 2.6 0 3 2.3 11/25/2006 13:20:00 5.2 0.5 6.5 3.8 5.1 0.6 6.1 3.4 5.2 0.5 6.5 3.8 134 8 135 165 2.6 0 2.8 2.3 11/25/2006 13:30:00 5.6 0.6 7.2 4.2 5.6 0.6 7.2 4.2 5.5 0.6 7.2 3.8 123 9 115 165 2.5 0.1 2.8 2.3 11/25/2006 13:40:00 5.5 0.5 7.2 4.2 5.4 0.5 7.6 3.8 5.3 0.5 6.8 3.8 131 8 124 165 2.7 0 2.8 2.3 11/25/2006 13:50:00 4.5 0.4 5.3 3.8 4.4 0.4 5.3 3.4 4.6 0.4 5.7 3.4 130 6 132 165 2.6 0 2.8 2.3 11/25/2006 14:00:00 4.4 0.5 5.7 3 4.4 0.6 5.7 3 4.4 0.5 5.7 3 131 7 129 165 1.7 0.2 2.6 1.4 11/25/2006 14:10:00 4.2 0.5 5.7 3.4 4.2 0.5 5.7 3 4.3 0.5 5.7 3 129 6 135 165 1.3 0.1 1.6 0.7 11/25/2006 14:20:00 3.6 0.5 4.6 2.6 3.7 0.5 4.9 2.6 3.6 0.4 4.6 2.6 123 5 127 165 1.5 0 1.8 0.9 11/25/2006 14:30:00 3.6 0.8 5.7 1.9 3.8 0.8 6.1 2.3 3.7 0.7 6.1 2.6 119 5 121 165 1.3 0.1 1.8 0.7 11/25/2006 14:40:00 5.9 0.7 7.2 4.2 6.2 0.7 7.6 4.2 5.9 0.7 7.6 3.8 122 7 127 165 1.1 0.1 1.4 0.7 11/25/2006 14:50:00 5.6 0.6 7.2 3.8 5.9 0.6 7.2 3.4 5.8 0.6 7.2 4.2 121 7 120 165 1.1 0 1.4 0.7 11/25/2006 15:00:00 5.5 0.6 6.8 4.2 5.7 0.6 7.2 4.2 5.6 0.6 7.6 3.8 125 6 114 165 0.9 0.1 1.4 0.2 11/25/2006 15:10:00 5.1 0.4 6.1 3.8 5.3 0.4 6.5 4.2 5.3 0.5 6.5 3.4 127 3 124 165 1 0 1.4 0.4 11/25/2006 15:20:00 4.3 0.5 5.3 3 4.5 0.5 5.7 3 4.5 0.4 6.1 3.4 125 8 136 165 0.9 0 1.4 0.9 11/25/2006 15:30:00 4.4 0.3 5.7 3.8 4.6 0.3 5.7 3.8 4.5 0.4 5.7 3.4 112 5 121 165 0.8 0 1.4 0.7 11/25/2006 15:40:00 4.5 0.3 5.3 3.4 4.8 0.3 5.3 3.8 4.7 0.4 5.7 3.4 110 4 99 165 0.7 0 0.9 0.7 11/25/2006 15:50:00 4.8 0.4 6.1 4.2 5 0.4 6.5 4.2 4.8 0.5 6.1 2.6 110 3 110 165 0.6 0 0.9 0.4 11/25/2006 16:00:00 5.5 0.4 6.5 4.2 5.7 0.4 6.5 4.6 5.4 0.4 6.5 4.2 111 3 111 165 0.7 0 0.9 0.7 11/25/2006 16:10:00 4.8 0.5 5.7 3.4 4.9 0.5 6.1 3.8 4.8 0.5 6.1 3.4 108 2 111 165 0.6 0 0.9 0.4 11/25/2006 16:20:00 5 0.6 6.5 3.8 5.2 0.6 6.8 4.2 5.1 0.6 6.5 3.4 109 5 113 165 0.5 0 0.9 0.4 11/25/2006 16:30:00 4.8 0.4 6.1 3.8 5 0.4 6.1 3.8 4.9 0.5 6.1 3.4 111 5 118 165 0.5 0 0.9 0.2 11/25/2006 16:40:00 5.5 0.5 6.5 4.2 5.7 0.5 6.5 4.6 5.4 0.6 6.5 3.4 104 3 102 165 0.5 0 0.9 0.2 11/25/2006 16:50:00 5.3 0.5 6.8 3.8 5.6 0.5 6.8 4.2 5.4 0.5 6.8 3.8 102 4 95 165 0.6 0 0.9 0.4 11/25/2006 17:00:00 5.5 0.9 7.2 3.4 5.7 0.9 7.2 3.8 5.4 0.8 7.6 3.8 101 9 107 165 0.7 0 0.9 0.4 11/25/2006 17:10:00 5.8 0.4 6.8 4.9 6 0.4 6.8 4.9 5.7 0.5 6.8 4.2 120 3 117 165 0.8 0 1.1 0.7 11/25/2006 17:20:00 5.8 0.6 7.2 4.2 6 0.6 7.2 4.6 5.7 0.6 7.2 3.8 118 4 122 165 0.8 0 0.9 0.7 11/25/2006 17:30:00 5.7 0.5 7.2 4.2 5.9 0.5 7.2 4.2 5.7 0.6 7.2 4.2 115 4 114 165 0.8 0 1.1 0.7 11/25/2006 17:40:00 5.4 0.5 6.8 3.8 5.7 0.5 6.8 4.2 5.4 0.5 6.5 3.8 121 3 122 165 0.8 0 1.1 0.7 11/25/2006 17:50:00 4.7 0.3 5.3 3.8 4.9 0.3 5.7 4.2 5 0.4 6.1 3.8 127 5 123 165 0.8 0 1.4 0.7 11/25/2006 18:00:00 4.5 0.3 5.3 3.8 4.6 0.2 5.3 4.2 4.7 0.2 5.3 3.8 130 5 136 165 0.7 0 0.9 0.7 11/25/2006 18:10:00 5.1 0.5 6.1 3.8 5.3 0.5 6.5 3.8 5.3 0.5 6.5 3.8 132 5 125 165 0.8 0 1.1 0.7 11/25/2006 18:20:00 4.2 0.5 5.3 3 4.3 0.5 5.7 3 4.4 0.4 5.7 3.4 134 4 131 165 0.8 0 1.4 0.9 11/25/2006 18:30:00 4.5 0.5 5.7 3 4.6 0.5 5.7 3 4.8 0.4 6.1 3.8 138 5 143 165 0.8 0 1.4 0.7 11/25/2006 18:40:00 3.3 0.7 4.9 1.1 3.4 0.7 4.9 1.1 3.7 0.6 5.3 2.3 153 15 137 165 0.9 0 1.4 0.9 11/25/2006 18:50:00 2.7 0.7 3.8 0.7 2.8 0.7 4.2 0.7 3 0.5 4.2 1.5 130 10 143 165 0.8 0 1.4 0.7 11/25/2006 19:00:00 2.1 0.4 3 1.1 2.2 0.4 3 1.1 2.5 0.3 3.4 1.5 127 6 115 165 0.8 0 1.1 0.7 11/25/2006 19:10:00 3.7 1 6.1 1.9 3.8 1 6.1 2.3 3.9 0.7 5.7 2.6 129 7 134 165 0.8 0 1.1 0.7 11/25/2006 19:20:00 4.5 0.6 5.7 2.6 4.5 0.6 5.7 3 4.6 0.6 5.7 3.4 141 13 130 165 0.5 0.2 0.9 -0.1 11/25/2006 19:30:00 6.2 1.9 9.9 3 6.1 2 9.5 2.6 6.5 1.9 10.3 3.4 162 11 162 165 -0.3 0.1 0.2 -0.5 11/25/2006 19:40:00 5.4 0.8 7.2 3.8 5.3 0.8 6.8 3.8 5.7 0.8 8 3.8 162 11 171 165 -0.6 0.2 -0.1 -0.8 11/25/2006 19:50:00 4.7 0.7 6.5 2.6 4.6 0.7 6.5 2.3 4.9 0.6 6.1 3.4 180 9 180 165 -0.8 0 -0.5 -0.8 11/25/2006 20:00:00 3.3 0.8 4.9 1.9 3.2 0.8 4.9 1.5 3.6 0.6 5.3 2.3 180 7 190 165 -0.7 0 -0.3 -0.8 11/25/2006 20:10:00 1.5 0.5 2.6 0.4 1.4 0.5 2.6 0.4 2 0.3 3 1.1 159 13 145 165 -0.6 0 -0.3 -0.8 11/25/2006 20:20:00 3.6 1 6.1 1.5 3.6 1 6.1 1.5 3.9 1.2 6.5 1.5 156 8 148 165 -0.3 0.1 -0.1 -0.5 11/25/2006 20:30:00 4.3 0.7 6.5 2.3 4.3 0.7 6.8 2.6 4.6 0.7 7.2 3 152 15 133 165 -0.1 0 0.2 -0.3 11/25/2006 20:40:00 5.2 0.6 6.8 3.8 5.2 0.5 6.8 4.2 5.4 0.5 7.2 3.8 153 6 154 165 -0.2 0 -0.1 -0.3 11/25/2006 20:50:00 5.1 0.5 6.8 3.8 5.1 0.5 6.8 3.8 5.3 0.5 6.8 4.2 154 5 145 165 -0.3 0 0.2 -0.3 11/25/2006 21:00:00 5.9 0.6 7.6 4.2 5.9 0.6 7.6 4.2 6.1 0.7 7.6 4.6 152 5 159 165 -0.2 0 0.2 -0.3 11/25/2006 21:10:00 5.1 1.1 7.2 3.4 5.1 1.1 7.2 3.4 5.3 1.1 7.6 3.4 153 5 154 165 -0.2 0 0.2 -0.3 11/25/2006 21:20:00 3.3 0.4 4.2 2.3 3.3 0.4 4.2 2.3 3.7 0.5 4.6 2.3 166 9 171 165 -0.3 0 -0.1 -0.5 11/25/2006 21:30:00 4.5 1.1 6.8 2.6 4.4 1 6.5 2.6 4.9 1 6.8 2.6 172 12 160 165 -0.3 0 -0.1 -0.5 11/25/2006 21:40:00 4.4 0.6 6.1 3 4.3 0.5 5.7 3 4.8 0.5 6.8 3.4 182 12 165 165 -0.4 0 -0.3 -0.5 11/25/2006 21:50:00 3.6 0.6 5.3 2.3 3.5 0.5 4.9 2.3 3.8 0.5 5.3 2.6 165 9 173 165 -0.4 0 -0.3 -0.5 11/25/2006 22:00:00 1.9 0.7 3.4 0.4 1.9 0.7 3 0.4 2.4 0.5 3.4 1.1 143 23 123 165 -0.3 0 -0.1 -0.5 11/25/2006 22:10:00 1.9 0.7 3.8 0.4 2 0.7 3.8 0.4 2.4 0.5 4.2 1.5 143 12 144 165 -0.3 0 0.2 -0.5 11/25/2006 22:20:00 0.8 0.5 3 0.4 0.9 0.6 3 0.4 1.9 0.4 3 1.1 160 10 156 165 -0.3 0 -0.1 -0.5 11/25/2006 22:30:00 0.8 0.5 2.3 0.4 0.8 0.5 2.3 0.4 1.6 0.3 2.6 1.1 151 10 157 165 -0.3 0 -0.1 -0.5 11/25/2006 22:40:00 1.3 0.6 2.3 0.4 1.3 0.6 2.3 0.4 2.1 0.3 2.6 1.5 162 3 160 165 -0.3 0 0.2 -0.5 11/25/2006 22:50:00 0.7 0.4 1.9 0.4 0.7 0.4 1.9 0.4 1.7 0.3 2.6 1.1 154 9 163 165 -0.3 0 0.2 -0.5 11/25/2006 23:00:00 0.4 0.2 1.5 0.4 0.4 0.2 1.5 0.4 1.4 0.3 2.3 0.7 158 6 154 165 -0.3 0 0.2 -0.5 11/25/2006 23:10:00 1 0.5 2.3 0.4 1.1 0.6 2.3 0.4 1.6 0.4 2.6 1.1 143 9 138 165 -0.5 0 -0.3 -0.5 11/25/2006 23:20:00 1 0.5 1.9 0.4 1.3 0.5 2.3 0.4 1.7 0.3 2.3 1.1 138 5 141 165 -0.4 0 -0.3 -0.5 11/25/2006 23:30:00 1.5 0.5 2.3 0.4 1.7 0.5 2.6 0.4 2.1 0.3 3 1.5 140 8 136 165 -0.3 0 -0.1 -0.5 11/25/2006 23:40:00 0.9 0.6 2.3 0.4 1.2 0.6 2.6 0.4 1.9 0.4 2.6 0.7 151 8 161 165 -0.2 0 -0.1 -0.3 11/25/2006 23:50:00 0.4 0.2 1.5 0.4 0.5 0.3 1.5 0.4 1.5 0.3 2.3 0.7 165 4 159 165 -0.2 0 0.2 -0.3 11/26/2006 00:00:00 1.4 0.5 2.3 0.4 1.5 0.4 2.6 0.7 2.3 0.3 3 1.9 171 5 174 165 -0.3 0 0.2 -0.3 11/26/2006 00:10:00 2.8 0.6 4.2 1.5 2.9 0.5 3.8 1.9 3.2 0.5 4.2 1.9 159 7 155 165 -0.3 0 -0.1 -0.3 11/26/2006 00:20:00 4.4 1 6.5 2.3 4.3 1 6.5 2.3 4.4 0.9 6.8 2.6 155 5 162 165 -0.2 0 0.2 -0.3 11/26/2006 00:30:00 5.1 0.7 6.8 3.4 5 0.6 6.8 3.8 5.3 0.6 7.2 4.2 160 6 155 165 0 0 0.2 -0.1 11/26/2006 00:40:00 5.1 0.7 6.8 3.4 5 0.7 6.5 3.4 5 0.6 6.8 3.4 158 5 162 165 0 0 0.2 -0.1 11/26/2006 00:50:00 5.6 0.8 7.2 3.4 5.5 0.8 7.2 3.8 5.6 0.8 8 3.8 161 9 159 165 0.1 0 0.2 -0.1 11/26/2006 01:00:00 5.5 0.7 7.2 3.8 5.3 0.6 6.5 3.4 5.7 0.6 7.2 3.8 166 12 163 165 0 0 0.2 -0.1 11/26/2006 01:10:00 4.6 0.5 6.1 3 4.5 0.5 6.1 3 4.6 0.5 6.5 3.4 178 8 165 165 0 0 0.2 -0.1 11/26/2006 01:20:00 4.4 0.2 4.9 3.4 4.3 0.2 4.9 3.4 4.7 0.3 5.3 3.8 188 3 187 165 0 0 0.2 -0.1 11/26/2006 01:30:00 4.7 0.2 4.9 4.2 4.6 0.2 4.9 4.2 5 0.2 5.3 4.2 181 3 184 165 0.1 0 0.2 -0.1 11/26/2006 01:40:00 4.8 0.5 6.5 3.8 4.6 0.5 6.1 3.8 4.8 0.4 6.1 3.8 172 6 169 165 0 0 0.2 -0.1 11/26/2006 01:50:00 3.9 0.4 5.3 3 3.8 0.4 5.3 3 4.1 0.3 4.9 3.4 164 9 169 165 -0.2 0 0.2 -0.3 11/26/2006 02:00:00 4.7 0.6 6.1 3.4 4.5 0.6 5.7 3.4 4.8 0.5 5.7 3.8 166 7 167 165 -0.2 0 -0.1 -0.3 11/26/2006 02:10:00 5.3 0.2 6.1 4.6 5 0.2 5.7 4.6 5.3 0.3 6.1 4.6 168 3 177 165 -0.2 0 -0.1 -0.3 11/26/2006 02:20:00 5.8 0.4 6.8 4.6 5.5 0.3 6.5 4.2 5.9 0.4 6.5 4.9 175 5 177 165 -0.1 0 0.2 -0.3 11/26/2006 02:30:00 5.4 0.5 6.5 4.2 5.2 0.4 6.1 4.2 5.6 0.4 6.5 4.6 179 3 179 165 0.1 0 0.2 -0.1 11/26/2006 02:40:00 6.1 0.4 7.2 5.3 5.8 0.3 6.8 4.9 6.1 0.4 7.2 5.3 177 3 172 165 0.2 0 0.7 0.2 11/26/2006 02:50:00 5.6 0.4 6.5 4.6 5.4 0.4 6.5 4.2 5.8 0.4 6.8 4.6 179 3 180 165 0.3 0 0.7 0.2 11/26/2006 03:00:00 5.8 0.3 6.5 4.6 5.6 0.3 6.5 4.6 5.9 0.4 6.8 4.9 175 3 179 165 0.3 0 0.7 0.2 11/26/2006 03:10:00 5.6 0.4 6.5 4.6 5.4 0.4 6.1 4.2 5.5 0.5 6.5 4.2 173 3 171 165 0.4 0 0.7 0.2 11/26/2006 03:20:00 6 0.4 7.2 4.9 5.8 0.4 6.8 4.9 6 0.4 7.2 4.9 167 11 165 165 0.5 0 0.7 0.2 11/26/2006 03:30:00 5.9 0.5 6.8 4.2 5.7 0.4 6.5 4.2 5.7 0.5 6.8 4.6 161 9 160 165 0.6 0 0.7 0.4 11/26/2006 03:40:00 4.7 0.6 6.5 3.4 4.7 0.5 6.1 3.4 4.9 0.5 6.5 3.8 157 4 165 165 0.5 0 0.9 0.4 11/26/2006 03:50:00 5.2 0.5 6.8 4.2 5.2 0.5 6.8 3.8 5.2 0.5 6.8 4.2 156 6 164 165 0.4 0 0.7 0.2 11/26/2006 04:00:00 6.6 1 8.8 4.6 6.4 0.9 8.4 4.6 6.4 1 8.8 4.6 159 10 158 165 0.4 0 0.7 0.2 11/26/2006 04:10:00 7.1 0.8 9.5 4.6 7 0.8 9.1 4.6 7.3 0.7 9.1 5.3 159 10 165 165 0.6 0 0.9 0.4 11/26/2006 04:20:00 8 0.7 9.9 6.1 7.8 0.7 9.5 6.1 8.1 0.8 10.3 5.7 160 13 165 165 0.7 0 0.9 0.7 11/26/2006 04:30:00 7.2 0.8 9.1 4.9 7 0.7 8.8 4.9 7.3 0.8 9.1 5.3 160 16 137 165 0.5 0 0.9 0.2 11/26/2006 04:40:00 7.3 0.6 8.8 5.7 7.2 0.6 8.8 5.7 7.4 0.6 9.1 5.7 160 6 159 165 0.5 0 0.9 0.2 11/26/2006 04:50:00 7.5 0.6 8.8 5.7 7.3 0.6 8.8 6.1 7.5 0.6 9.5 6.1 161 14 161 165 0.5 0 0.9 0.2 11/26/2006 05:00:00 7.4 0.6 9.1 6.1 7.3 0.6 8.8 5.7 7.4 0.6 9.1 5.7 157 10 158 165 0.4 0 0.7 0.2 11/26/2006 05:10:00 7.4 0.7 9.1 5.7 7.3 0.7 8.8 5.3 7.3 0.6 8.8 6.1 158 8 149 165 0.5 0 0.9 0.2 11/26/2006 05:20:00 8.4 1.1 10.7 6.1 8.2 1.1 10.3 6.1 8.5 1.2 11.1 6.1 155 7 161 165 0.7 0 0.9 0.4 11/26/2006 05:30:00 9.6 0.6 11.1 7.6 9.5 0.6 10.7 7.6 9.8 0.6 11.5 8 156 4 158 165 0.8 0 1.1 0.7 11/26/2006 05:40:00 9.8 0.9 11.5 7.6 9.7 0.9 11.5 7.2 10.2 1 12.2 8 154 4 154 165 0.9 0 1.4 0.9 11/26/2006 05:50:00 10.5 0.5 11.8 8.4 10.4 0.5 11.5 8.8 10.8 0.6 12.2 8.8 155 4 160 165 0.9 0 1.4 0.9 11/26/2006 06:00:00 10.7 0.6 12.2 9.1 10.6 0.5 12.2 9.1 11.1 0.7 13.3 8.8 154 4 156 165 1 0 1.4 0.9 11/26/2006 06:10:00 10.1 0.6 11.5 8.4 10 0.6 11.5 8 10.4 0.7 11.8 8.4 155 3 153 165 0.9 0 1.4 0.9 11/26/2006 06:20:00 9.5 0.6 11.1 7.6 9.4 0.6 11.1 7.2 9.9 0.6 11.5 8 154 5 160 165 1 0 1.4 0.9 11/26/2006 06:30:00 9.8 0.5 11.1 8 9.7 0.5 10.7 8 10 0.5 11.1 8.4 156 4 152 165 1 0 1.4 0.9 11/26/2006 06:40:00 9.1 0.5 10.3 7.6 9 0.5 10.3 7.6 9.5 0.5 10.7 8.4 156 3 158 165 1.1 0 1.4 0.9 11/26/2006 06:50:00 9.3 0.6 10.7 7.6 9.2 0.5 10.3 7.6 9.6 0.6 11.1 8 155 3 156 165 1.1 0 1.4 0.9 11/26/2006 07:00:00 9.2 0.3 9.9 8.4 9.1 0.3 10.3 8 9.5 0.4 10.7 8 154 3 160 165 1.1 0 1.4 0.9 11/26/2006 07:10:00 9.5 0.5 10.7 8 9.5 0.5 10.7 8 9.7 0.5 11.1 8 153 3 156 165 1.1 0 1.4 0.9 11/26/2006 07:20:00 9.9 0.4 11.1 8.4 9.8 0.4 11.1 8 10.1 0.5 11.1 8.4 154 2 154 165 1.2 0 1.6 1.1 11/26/2006 07:30:00 9.8 0.6 12.6 8 9.6 0.6 12.2 7.6 10.1 0.6 12.6 8.8 155 4 156 165 1.2 0 1.6 1.1 11/26/2006 07:40:00 10.8 1.1 13.3 7.6 10.7 1.2 13.3 7.6 11.1 1.1 13.3 8.4 152 6 156 165 0.9 0.1 1.4 0.9 11/26/2006 07:50:00 10.1 0.8 12.6 8 9.8 0.8 12.6 8 10.3 0.9 13.3 7.6 159 12 151 165 1.1 0 1.4 0.9 11/26/2006 08:00:00 8.5 1 11.1 6.8 8.4 1 11.1 6.8 8.8 1 11.8 6.5 163 17 165 165 1.1 0 1.6 0.9 11/26/2006 08:10:00 11.2 1.2 13.3 7.6 11.1 1.2 13 7.6 11.3 1.3 13.7 7.6 153 7 154 165 0.5 0.3 1.4 0.2 11/26/2006 08:20:00 9.7 1.3 13 7.6 9.5 1.4 13 7.2 9.9 1.3 13.3 7.2 159 18 157 165 0.1 0 0.4 -0.1 11/26/2006 08:30:00 8.5 0.8 9.9 6.1 8.3 0.7 9.5 5.7 8.5 0.7 9.9 6.5 159 16 159 165 -0.1 0 0.2 -0.1 11/26/2006 08:40:00 7.6 0.7 9.1 5.7 7.4 0.6 9.1 5.7 7.7 0.6 9.1 6.1 161 11 157 165 0.1 0 0.2 -0.1 11/26/2006 08:50:00 7.9 0.6 9.5 5.7 7.7 0.6 9.1 5.3 8.1 0.6 9.9 6.8 167 8 162 165 0.1 0 0.2 -0.1 11/26/2006 09:00:00 8.5 1.5 11.8 6.1 8.4 1.5 11.8 6.1 8.7 1.4 12.2 6.1 160 12 160 165 0.1 0 0.2 -0.1 11/26/2006 09:10:00 10.2 0.8 12.6 8.4 10.2 0.9 13 8 10.4 1 13.3 8 154 10 163 165 0 0 0.2 -0.1 11/26/2006 09:20:00 9.8 0.8 11.8 7.2 9.7 0.8 11.8 7.6 9.9 0.9 12.2 7.2 153 10 156 165 0.1 0 0.2 -0.1 11/26/2006 09:30:00 10.3 0.8 12.6 7.6 10.2 0.8 12.6 7.6 10.5 0.9 13.3 8 153 7 147 165 0.1 0 0.2 -0.1 11/26/2006 09:40:00 10.6 0.8 12.6 8.8 10.6 0.8 12.6 8.8 10.7 0.8 12.6 8.8 153 11 154 165 0.1 0 0.2 -0.1 11/26/2006 09:50:00 10.6 1 13 8.4 10.6 1.1 13.3 8 10.3 1.2 13 7.2 154 13 161 165 0.2 0 0.2 -0.1 11/26/2006 10:00:00 10.6 0.8 12.2 8.8 10.6 0.8 12.2 8 10.7 1 13 7.6 151 6 153 165 0.1 0 0.2 -0.1 11/26/2006 10:10:00 10.8 0.6 12.6 9.5 10.7 0.6 12.6 9.5 10.9 0.7 13 8.8 153 4 153 165 0.1 0 0.2 -0.1 11/26/2006 10:20:00 10.1 0.6 11.5 8.4 10.1 0.6 11.5 8 10.1 0.8 11.8 6.8 150 6 144 165 0.1 0 0.2 -0.1 11/26/2006 10:30:00 10.7 0.6 11.8 8.8 10.7 0.5 11.8 8.8 10.9 0.7 12.6 8 151 4 152 165 0.1 0 0.2 -0.1 11/26/2006 10:40:00 10.4 0.5 11.8 8 10.4 0.5 11.8 8 10.5 0.6 12.2 8.4 152 4 153 165 0.1 0 0.2 -0.1 11/26/2006 10:50:00 9.9 0.5 11.1 8 9.9 0.5 11.1 8.4 9.9 0.6 11.5 8 151 3 154 165 0.1 0 0.2 -0.1 11/26/2006 11:00:00 10.8 0.5 12.2 9.5 10.7 0.5 11.8 9.1 11.1 0.6 12.6 8.8 152 3 152 165 0 0 0.2 -0.1 11/26/2006 11:10:00 11.3 0.9 13.3 9.1 11.3 1 13.3 9.1 11.4 1 13.7 8.8 150 4 145 165 0.1 0 0.2 -0.1 11/26/2006 11:20:00 11.5 0.8 13.3 9.5 11.5 0.8 13.3 9.1 11.6 1 13.7 9.1 150 3 155 165 0.1 0 0.4 -0.1 11/26/2006 11:30:00 10.3 0.7 11.5 8.4 10.2 0.7 11.8 8.4 10.3 0.7 11.8 8.8 151 3 151 165 0.1 0 0.2 -0.1 11/26/2006 11:40:00 9.8 0.6 11.1 8.4 9.6 0.6 11.1 8 9.7 0.6 11.5 7.6 153 0 154 165 0.2 0 0.4 0.2 11/26/2006 11:50:00 9.7 0.5 11.8 8.4 9.5 0.5 11.5 8 9.8 0.5 11.5 7.6 153 0 154 165 0.2 0 0.4 0.2 11/26/2006 12:00:00 10.2 0.5 11.5 9.1 10 0.5 11.1 8.8 10.4 0.6 11.5 7.6 153 0 153 165 0.2 0 0.2 0.2 11/26/2006 12:10:00 9.8 0.5 11.1 8 9.6 0.6 10.7 7.6 9.9 0.7 11.5 7.6 153 0 154 165 0.2 0 0.4 0.2 11/26/2006 12:20:00 8.7 0.5 10.3 7.2 8.4 0.5 9.9 6.8 8.9 0.5 10.3 6.8 153 0 154 165 0.2 0 0.4 0.2 11/26/2006 12:30:00 9 0.7 11.1 7.2 8.8 0.8 10.7 6.8 9.1 0.8 11.1 6.8 153 0 153 165 0.3 0 0.7 0.2 11/26/2006 12:40:00 10.2 0.8 11.8 8.4 10 0.8 11.8 7.6 10.3 0.8 12.2 8.4 153 0 153 165 0.2 0 0.7 0.2 11/26/2006 12:50:00 9.7 0.4 10.7 8 9.5 0.4 10.3 8 9.8 0.5 10.7 8.4 153 0 153 165 0.3 0 0.7 0.2 11/26/2006 13:00:00 11.5 1 14.1 9.5 11.3 1 13.7 9.1 11.5 1.1 14.1 9.1 153 0 153 165 0.4 0 0.7 0.2 11/26/2006 13:10:00 11.8 1.2 14.9 8.8 11.5 1.2 14.5 8.8 11.7 1.3 15.3 8 153 0 154 165 0.1 0 0.2 -0.1 11/26/2006 13:20:00 9.7 0.8 11.8 7.6 9.5 0.9 11.5 7.2 10 0.8 11.8 8 153 0 154 165 0.2 0 0.4 -0.1 11/26/2006 13:30:00 9.4 0.5 10.7 8 9.1 0.5 10.3 8 9.5 0.5 10.7 7.6 153 0 153 165 0.2 0 0.7 0.2 11/26/2006 13:40:00 9.5 0.4 10.7 8.4 9.2 0.5 10.3 8 9.6 0.5 11.1 8.4 153 0 154 165 0.2 0 0.7 0.2 11/26/2006 13:50:00 11.5 0.9 13.3 9.5 11.1 0.9 12.6 9.5 11.5 1 13.7 9.1 153 0 153 165 0.3 0 0.7 0.2 11/26/2006 14:00:00 12.4 0.7 14.9 10.3 12 0.7 13.7 9.9 12.4 0.7 14.1 10.3 153 0 154 165 0.3 0 0.7 0.2 11/26/2006 14:10:00 12.5 0.5 13.7 11.1 12.2 0.5 13.3 10.7 12.5 0.6 13.7 10.3 153 0 153 165 0.2 0 0.7 0.2 11/26/2006 14:20:00 13.4 0.7 14.9 11.5 13.1 0.7 14.5 11.5 13.3 0.9 15.3 10.3 153 0 153 165 0.3 0 0.7 0.2 11/26/2006 14:30:00 13.3 1 15.3 10.3 12.9 1 14.9 10.3 13.1 1.2 15.3 10.7 153 0 153 165 0.4 0 0.7 0.2 11/26/2006 14:40:00 13.5 0.7 15.3 11.1 13.2 0.7 15.3 11.1 13.3 0.9 14.9 9.9 153 0 158 165 0.2 0 0.4 0.2 11/26/2006 14:50:00 14.3 0.7 16.4 12.2 13.9 0.6 15.6 11.8 14.1 0.9 16.1 11.1 153 0 153 165 0.2 0 0.7 -0.1 11/26/2006 15:00:00 14.2 0.8 15.6 11.5 13.8 0.8 15.3 11.1 14.2 1 16.1 10.7 153 0 153 165 0.2 0 0.4 -0.1 11/26/2006 15:10:00 14.4 0.8 16.4 12.2 14.1 0.8 15.6 11.8 14.3 1.1 16.4 11.5 153 0 154 165 0.1 0 0.2 -0.1 11/26/2006 15:20:00 13.2 0.8 14.9 10.7 12.9 0.9 14.9 9.9 13 1.1 15.3 9.9 153 0 153 165 0.2 0 0.7 0.2 11/26/2006 15:30:00 13.9 0.6 15.6 12.2 13.6 0.6 14.9 11.8 13.7 0.7 15.6 11.5 153 0 153 165 0.1 0 0.4 -0.1 11/26/2006 15:40:00 13.5 0.7 15.3 11.8 13.2 0.7 14.9 11.5 13.5 0.8 15.3 10.7 153 0 153 165 0.1 0 0.2 -0.1 11/26/2006 15:50:00 14.6 1.4 17.9 11.5 14.2 1.3 17.2 11.1 14.3 1.5 17.6 10.7 153 0 154 165 0.2 0 0.4 -0.1 11/26/2006 16:00:00 13.8 0.9 15.6 11.1 13.4 0.8 15.3 11.1 13.7 1 15.6 10.7 153 0 153 165 0 0 0.7 -0.1 11/26/2006 16:10:00 13.4 0.7 15.3 11.5 13 0.7 14.5 11.1 13.4 0.8 14.9 10.7 153 0 153 165 0.1 0 0.2 -0.1 11/26/2006 16:20:00 12.7 1 16.1 9.5 12.4 1 15.6 8.8 12.7 1 15.3 9.9 153 0 153 165 0.1 0 0.2 -0.1 11/26/2006 16:30:00 12.3 0.8 14.1 9.5 11.9 0.8 13.7 9.5 12.3 0.8 14.5 9.9 153 0 153 165 0.1 0 0.2 -0.1 11/26/2006 16:40:00 12.7 1 14.5 10.3 12.3 1 14.1 10.3 12.6 1.2 14.9 9.5 153 0 153 165 0.1 0 0.4 -0.1 11/26/2006 16:50:00 13.1 0.8 14.9 9.9 12.6 0.8 14.1 9.5 12.9 1 14.9 10.3 153 0 153 165 0.2 0 0.4 0.2 11/26/2006 17:00:00 14.2 0.9 16.4 11.5 13.8 0.9 16.1 11.5 14 1.2 16.4 9.9 153 0 153 165 0.3 0 0.7 0.2 11/26/2006 17:10:00 15 0.8 16.8 13 14.7 0.8 16.4 12.2 14.9 0.8 16.8 11.8 153 0 153 165 0.4 0 0.9 0.2 11/26/2006 17:20:00 15.3 0.8 17.6 13 14.8 0.7 17.2 12.6 14.9 0.9 17.2 12.2 153 0 153 165 0.3 0.1 0.7 0.2 11/26/2006 17:30:00 14.5 0.9 16.8 12.2 14 0.9 16.1 11.8 14 1 16.4 11.1 153 0 153 165 0.2 0 0.7 0.2 11/26/2006 17:40:00 13.9 0.8 15.6 11.5 13.3 0.8 15.3 10.7 13.2 1 15.3 9.9 153 0 153 165 0.3 0 0.7 0.2 11/26/2006 17:50:00 14.8 1 16.8 12.2 14.1 0.9 16.1 11.8 13.9 1 16.1 11.5 153 0 153 165 0.3 0.1 0.7 0.2 11/26/2006 18:00:00 15.1 1 17.2 11.8 14.2 1 16.1 11.5 14.3 1.1 16.8 11.5 153 0 153 165 0.2 0 0.4 0.2 11/26/2006 18:10:00 14.1 1.2 16.4 11.1 13.3 1.1 15.6 10.3 13.6 1.1 15.6 10.3 153 0 153 165 0.2 0 0.7 0.2 11/26/2006 18:20:00 13.7 1 16.1 10.7 12.8 1.1 15.3 9.5 13.4 1.2 16.1 9.9 153 0 153 165 0.3 0 0.7 0.2 11/26/2006 18:30:00 15.8 1.1 18.3 12.6 15 1.2 17.6 11.8 15.5 1.2 17.6 11.8 153 0 153 165 0.4 0 0.7 0.2 11/26/2006 18:40:00 15.3 0.7 16.8 13.3 14.5 0.8 16.4 12.2 15.1 0.8 16.8 12.6 153 0 153 165 0.2 0 0.7 0.2 11/26/2006 18:50:00 15.3 0.9 17.6 13 14.6 1 16.8 11.8 15.1 0.9 17.6 12.2 153 0 153 165 0.5 0 0.7 0.2 11/26/2006 19:00:00 15.7 0.9 17.6 13.3 14.8 1 16.8 12.2 15.6 1 17.9 12.6 153 0 153 165 0.3 0 0.9 0.2 11/26/2006 19:10:00 16.2 1 17.9 13.3 15.5 1 17.6 12.6 16.2 1.1 18.7 12.6 153 0 153 165 0.5 0 0.7 0.4 11/26/2006 19:20:00 16.5 0.8 19.1 13.7 15.8 0.9 18.7 13.3 16.3 1 18.7 13.3 153 0 153 165 0.5 0 0.9 0.2 11/26/2006 19:30:00 15.6 1.3 17.9 11.1 15 1.4 17.2 10.3 15.4 1.2 17.9 11.1 153 0 153 165 0.3 0 0.7 0.2 11/26/2006 19:40:00 14.4 1 16.8 11.5 13.6 1.1 16.1 10.3 14.3 1 16.4 11.1 153 0 153 165 0.5 0 0.7 0.2 11/26/2006 19:50:00 15.9 0.8 17.9 13.3 15.1 0.8 16.8 12.2 15.6 0.8 17.2 13 153 0 153 165 0.5 0 0.9 0.2 11/26/2006 20:00:00 16.3 0.9 18.3 13.7 15.5 1 17.9 13 16 1 18.7 12.6 153 0 153 165 0.5 0 0.7 0.4 11/26/2006 20:10:00 16.4 1 19.1 13.7 15.6 1 17.9 12.6 16.2 1.1 18.7 13.3 153 0 154 165 0.6 0 0.9 0.4 11/26/2006 20:20:00 16.5 0.8 18.3 14.1 15.4 0.9 17.6 12.2 16.1 1 18.3 12.6 153 0 153 165 0.6 0 0.9 0.4 11/26/2006 20:30:00 16.9 1 18.7 14.1 16.6 1.1 18.7 13.3 16.3 1.1 18.3 13 153 0 153 165 0.5 0 0.9 0.4 11/26/2006 20:40:00 17.6 1.3 20.6 13 17.2 1.3 20.2 12.6 16.9 1.3 20.2 12.6 153 0 153 165 0.4 0 0.7 0.2 11/26/2006 20:50:00 17.7 0.9 19.5 14.9 17.3 0.9 19.5 14.5 16.9 1.1 19.1 13.3 153 0 153 165 0.2 0 0.7 0.2 11/26/2006 21:00:00 16.8 1.4 20.2 14.1 16.4 1.3 19.9 13.3 16.1 1.5 19.9 12.6 153 0 153 165 0.3 0 0.7 0.2 11/26/2006 21:10:00 18.3 1 20.6 15.3 17.9 1 20.2 14.9 17.6 1.1 20.6 13.7 153 0 153 165 0.2 0 0.7 -0.1 11/26/2006 21:20:00 17.4 1.1 20.2 14.1 16.9 1.1 19.9 13.7 16.7 1.2 19.9 13.7 153 0 154 165 0.2 0 0.4 -0.1 11/26/2006 21:30:00 17.6 1.5 20.2 14.5 17.2 1.4 19.9 14.1 17.1 1.6 20.2 13.3 153 0 153 165 0.1 0 0.2 -0.1 11/26/2006 21:40:00 18.4 1.1 20.2 15.3 18 1 19.9 14.9 17.7 1.2 20.2 14.1 153 0 153 165 0.2 0 0.7 0.2 11/26/2006 21:50:00 17.7 1.1 20.2 14.5 17.4 1.1 19.9 14.1 17.1 1.3 20.2 14.1 153 0 153 165 0.2 0 0.7 0.2 11/26/2006 22:00:00 17.7 1 19.9 15.6 17.4 0.9 19.9 14.9 17 1.1 19.9 13.7 153 0 153 165 0.3 0 0.7 0.2 11/26/2006 22:10:00 16.4 1.1 18.3 13 15.9 1.2 17.9 11.8 15.5 1.5 17.9 10.3 153 0 153 165 0.3 0 0.7 0.2 11/26/2006 22:20:00 17 1 20.2 14.5 16.4 1 19.5 13.7 16.2 1.1 19.5 13.7 153 0 153 165 0.3 0 0.7 0.2 11/26/2006 22:30:00 16.7 1 18.7 13 16.2 0.9 17.9 13 16.1 1 18.3 13 153 0 153 165 0.3 0 0.7 0.2 11/26/2006 22:40:00 17 1.3 19.9 13.3 16.3 1.2 18.7 13 16.4 1.2 19.1 13 153 0 153 165 0.3 0 0.7 0.2 11/26/2006 22:50:00 16.2 1.5 19.5 12.6 15.7 1.5 19.1 11.8 15.5 1.4 18.7 11.8 153 0 153 165 0.4 0 0.7 0.2 11/26/2006 23:00:00 17.1 1 19.1 14.1 16.1 1 17.9 13 16.3 1.1 19.1 13 153 0 153 165 0.2 0 0.7 0.2 11/26/2006 23:10:00 16.8 1.2 18.7 12.2 16.2 1 17.9 12.2 16.4 1.2 18.7 12.6 153 0 153 165 0.1 0 0.2 -0.1 11/26/2006 23:20:00 15.6 1 17.9 13 15.7 1 17.9 12.6 15.6 1.2 17.6 12.2 153 0 153 165 0.1 0 0.4 -0.1 11/26/2006 23:30:00 15.5 0.9 17.6 13.3 15.8 0.9 17.9 13.3 15.6 1.1 18.3 12.2 153 0 153 165 0.2 0 0.7 0.2 11/26/2006 23:40:00 15.2 1.3 17.6 12.2 15.7 1.4 18.3 12.6 15.6 1.5 18.7 11.8 153 0 153 165 0.2 0 0.4 -0.1 11/26/2006 23:50:00 15.6 1.1 18.3 12.6 14.8 1.1 17.2 11.1 15 1.2 17.6 11.1 153 0 153 165 0.1 0 0.2 -0.1 11/27/2006 00:00:00 9.2 3.1 15.6 6.8 13.5 2.5 17.2 7.6 14.2 1.1 16.8 11.5 153 0 153 165 0.1 0 0.2 -0.1 11/27/2006 00:10:00 7.2 0.2 7.6 6.8 7.9 0.2 8.4 7.6 13.9 1 16.1 10.7 153 0 153 165 0.1 0 0.7 -0.1 11/27/2006 00:20:00 7 0.2 7.2 6.5 7.7 0.2 8 7.2 13.4 1 16.1 11.1 153 0 153 165 0.1 0 0.4 -0.1 11/27/2006 00:30:00 6.8 0.2 7.2 6.5 7.5 0.2 8 7.2 13.3 1 15.6 10.3 153 0 153 165 0.1 0 0.7 -0.1 11/27/2006 00:40:00 6.6 0.2 7.2 6.1 7.3 0.2 7.6 6.8 12.1 1.1 14.5 9.5 153 0 153 165 0.1 0 0.2 -0.1 11/27/2006 00:50:00 6.3 0.2 6.8 5.7 7.1 0.2 7.2 6.8 11.8 1.5 14.9 9.1 153 0 154 165 0.1 0 0.2 -0.1 11/27/2006 01:00:00 6.1 0.2 6.5 5.3 7 0.2 7.2 6.5 12.4 0.9 14.1 9.5 153 0 154 165 0.1 0 0.2 -0.1 11/27/2006 01:10:00 6 0.2 6.5 5.3 6.6 0.4 7.2 5.3 12 1.2 14.1 8.8 153 0 153 165 0.1 0 0.7 -0.1 11/27/2006 01:20:00 6 0.2 6.5 5.3 6.3 0.4 6.8 5.3 11.5 0.6 13 9.9 153 0 153 165 0.1 0 0.2 -0.1 11/27/2006 01:30:00 5.9 0.2 6.5 5.3 6.4 0.3 6.8 5.7 11.9 0.7 13.7 10.3 153 0 153 165 0.1 0 0.2 -0.1 11/27/2006 01:40:00 5.8 0.2 6.5 5.3 6.3 0.3 6.8 5.3 10.5 2.6 13.7 6.5 153 0 153 165 0.1 0 0.2 -0.1 11/27/2006 01:50:00 5.7 0.2 6.5 4.9 6.2 0.3 6.8 5.3 6.6 0.2 7.2 5.7 153 0 153 165 0.1 0 0.7 -0.1 11/27/2006 02:00:00 5.7 0.2 6.1 5.3 6.2 0.3 6.5 5.3 6.4 0.2 6.8 5.7 153 0 153 165 0.1 0 0.2 -0.1 11/27/2006 02:10:00 5.5 0.2 6.1 4.9 5.9 0.3 6.5 4.9 6.1 0.2 6.5 5.7 153 0 153 165 0.1 0 0.2 -0.1 11/27/2006 02:20:00 5.3 0.2 5.7 4.6 5.6 0.4 6.1 4.6 5.9 0.2 6.5 4.9 153 0 153 165 0.1 0 0.2 -0.1 11/27/2006 02:30:00 5.2 0.3 6.1 4.6 5.4 0.3 6.1 4.2 5.8 0.3 6.5 4.9 153 0 153 165 0.2 0 0.4 0.2 11/27/2006 02:40:00 5.7 0.3 6.1 4.9 5.2 0.4 6.1 4.2 5.5 0.3 6.1 4.6 153 0 153 165 0.2 0 0.7 0.2 11/27/2006 02:50:00 5.5 0.3 6.1 4.6 4.9 0.4 5.7 3.8 5.2 0.4 6.1 4.2 153 0 153 165 0.2 0 0.4 0.2 11/27/2006 03:00:00 5.2 0.3 6.1 4.2 4.5 0.4 5.3 3 4.8 0.4 5.7 3.8 153 0 153 165 0.2 0 0.7 0.2 11/27/2006 03:10:00 5.3 0.3 5.7 4.6 4.7 0.3 5.3 3.8 5.1 0.4 6.1 4.2 153 0 153 165 0.3 0 0.7 0.2 11/27/2006 03:20:00 5.1 0.3 5.7 4.6 4.9 0.5 5.7 3 4.9 0.4 5.7 3.8 153 0 153 165 0.4 0 0.7 0.2 11/27/2006 03:30:00 5.1 0.3 5.7 4.6 4.8 0.4 5.7 3.4 4.8 0.4 5.7 3.4 153 0 153 165 0.4 0 0.7 0.2 11/27/2006 03:40:00 5.1 0.2 5.7 4.6 5 0.5 5.7 3.4 4.9 0.4 5.7 3 153 0 153 165 0.5 0 0.7 0.4 11/27/2006 03:50:00 5.1 0.2 5.7 4.6 5.1 0.4 6.1 3.8 4.9 0.4 5.7 3.8 153 0 153 165 0.5 0 0.9 0.4 11/27/2006 04:00:00 5.1 0.2 5.7 4.6 5.8 0.4 6.5 4.6 5.1 0.3 5.7 4.2 153 0 153 165 0.6 0 0.9 0.4 11/27/2006 04:10:00 4.9 0.2 5.3 4.2 5.6 0.3 6.1 4.6 4.9 0.3 5.7 4.2 153 0 153 165 0.7 0 0.9 0.7 11/27/2006 04:20:00 4.9 0.2 5.3 4.2 5.4 0.3 6.1 4.6 4.7 0.3 5.3 4.2 153 0 153 165 0.7 0 0.9 0.7 11/27/2006 04:30:00 4.7 0.2 5.3 4.2 4.9 0.4 5.7 3.8 4.2 0.4 4.9 3 153 0 153 165 0.8 0 0.9 0.7 11/27/2006 04:40:00 4.7 0.2 5.3 3.8 5 0.3 5.7 3.8 4.2 0.3 4.6 3 153 0 153 165 0.8 0 0.9 0.7 11/27/2006 04:50:00 4.6 0.2 4.9 4.2 4.8 0.3 5.3 4.2 4 0.4 4.6 3 153 0 153 165 0.8 0 0.9 0.7 11/27/2006 05:00:00 4.5 0.2 4.9 4.2 4.5 0.2 4.9 3.8 3.6 0.4 4.6 2.6 153 0 153 165 0.8 0 1.1 0.9 11/27/2006 05:10:00 4.3 0.3 4.9 3.4 4.3 0.3 4.6 2.6 2.9 0.7 4.2 1.1 153 0 153 165 0.9 0 1.1 0.9 11/27/2006 05:20:00 4.1 0.2 4.6 3.4 4 0.4 4.6 2.6 2 0.3 2.6 1.5 153 0 153 165 0.9 0 1.1 0.9 11/27/2006 05:30:00 4 0.3 4.6 3 3.6 0.4 4.6 2.6 0.7 0.6 2.3 0.4 153 0 153 165 0.9 0 1.4 0.9 11/27/2006 05:40:00 3.3 0.5 4.6 2.3 2.5 0.4 3.8 1.5 0.4 0 0.4 0.4 153 0 153 165 1 0 1.4 0.9 11/27/2006 05:50:00 3.4 0.3 3.8 2.3 2.7 0.4 3.4 1.5 0.4 0 0.4 0.4 153 0 153 165 1 0 1.1 0.9 11/27/2006 06:00:00 2.9 0.7 4.2 1.9 2.5 0.5 3.8 1.5 0.4 0 0.4 0.4 153 0 154 165 1.1 0 1.4 0.9 11/27/2006 06:10:00 3.3 0.7 4.6 1.9 2 1 3 0.4 0.4 0 0.4 0.4 153 0 153 165 1.1 0 1.4 0.9 11/27/2006 06:20:00 1.9 0.4 2.6 1.1 0.4 0 0.4 0.4 0.4 0 0.4 0.4 153 0 153 165 1.1 0 1.4 0.9 11/27/2006 06:30:00 0.9 0.5 1.9 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 153 0 153 165 1.2 0 1.4 0.9 11/27/2006 06:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 153 0 165 165 1.2 0 1.4 1.1 11/27/2006 06:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 153 0 165 165 1.2 0 1.4 1.1 11/27/2006 07:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 151 5 165 165 1.3 0 1.4 1.1 11/27/2006 07:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 141 5 165 165 1.3 0 1.4 1.4 11/27/2006 07:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 141 1 165 165 1.3 0 1.4 1.4 11/27/2006 07:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 140 0 165 165 1.4 0 1.4 1.4 11/27/2006 07:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 140 0 165 165 1.4 0 1.6 1.4 11/27/2006 07:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 140 4 165 165 1.4 0 1.6 1.4 11/27/2006 08:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 143 5 165 165 1.4 0 1.6 1.4 11/27/2006 08:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 146 5 165 165 1.4 0 1.6 1.4 11/27/2006 08:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 147 5 165 165 1.4 0 1.6 1.4 11/27/2006 08:30:00 0.4 0 0.4 0.4 2.2 0.8 3.4 0.4 0.4 0 0.4 0.4 144 7 165 165 1.4 0 1.6 1.4 11/27/2006 08:40:00 0.4 0 0.4 0.4 3 0.5 3.8 1.9 0.4 0 0.4 0.4 146 5 165 165 1.4 0 1.6 1.4 11/27/2006 08:50:00 0.4 0 0.4 0.4 2.6 0.6 3.8 1.5 0.4 0 0.4 0.4 146 7 165 165 1.5 0 1.6 1.4 11/27/2006 09:00:00 0.4 0 0.4 0.4 3 0.5 4.2 1.9 0.4 0.1 1.1 0.4 150 6 165 165 1.5 0 1.6 1.4 11/27/2006 09:10:00 0.4 0 0.4 0.4 3.7 0.5 4.9 2.6 1 0.5 1.9 0.4 142 6 165 165 1.5 0 1.6 1.4 11/27/2006 09:20:00 2 1 3.8 0.4 4.1 0.5 5.3 2.3 0.4 0.1 1.1 0.4 144 6 147 165 1.5 0 1.6 1.4 11/27/2006 09:30:00 3.5 0.7 4.6 1.1 4.5 0.6 5.7 2.6 4.3 3.2 8 0.4 143 6 150 165 1.5 0 1.8 1.4 11/27/2006 09:40:00 3.4 0.5 4.2 2.3 4.4 0.5 5.3 3 7.1 0.5 8 5.3 149 5 145 165 1.5 0 1.6 1.4 11/27/2006 09:50:00 3.3 0.4 4.6 1.9 4.2 0.5 5.3 3 6.8 0.6 8 4.9 153 12 143 165 1.6 0 1.8 1.4 11/27/2006 10:00:00 2.9 0.5 4.2 1.5 3.8 0.5 4.9 2.6 6.2 0.9 8 3.8 149 11 156 165 1.7 0 1.8 1.6 11/27/2006 10:10:00 3.1 1.1 6.1 1.1 5 1.2 8.8 2.6 7.6 1.3 11.1 3.4 152 8 140 165 1.9 0 2.3 1.6 11/27/2006 10:20:00 5.1 0.7 6.5 3.4 7.9 1.3 11.1 4.9 8 1.1 11.5 4.9 142 11 137 165 1.8 0.1 2.3 1.6 11/27/2006 10:30:00 6.5 1.7 11.5 3 7.9 1 11.5 4.6 7.8 1.1 11.8 4.2 146 9 142 165 1.7 0 1.8 1.6 11/27/2006 10:40:00 7.9 0.8 9.9 6.1 7.8 0.8 9.9 6.1 7.9 0.8 10.3 5.3 153 6 141 165 2.2 0.3 2.8 1.8 11/27/2006 10:50:00 7.1 0.8 8.8 4.9 7 0.8 8.8 4.9 6.9 0.8 8.8 3.4 149 10 154 165 2.6 0 2.8 2.6 11/27/2006 11:00:00 7.2 1 9.9 4.9 7.2 1 9.9 4.6 7 1 9.9 4.6 148 10 145 165 2.7 0 2.8 2.6 11/27/2006 11:10:00 7.5 1.2 11.5 4.6 7.5 1.2 11.1 4.6 7.4 1.3 10.3 3.8 148 7 160 165 2.7 0 2.8 2.6 11/27/2006 11:20:00 7.9 1.1 12.2 5.3 7.9 1.1 11.8 5.3 7.8 1 10.7 5.3 147 9 138 165 2.9 0 3 2.8 11/27/2006 11:30:00 8.2 0.8 10.7 6.5 8.1 0.8 10.3 5.3 8.1 0.8 10.7 6.1 145 8 144 165 3 0.1 3.3 2.8 11/27/2006 11:40:00 9 1.2 11.8 6.1 9 1.2 11.8 6.1 9 1.3 11.8 5.7 149 7 148 165 3.1 0 3.3 2.8 11/27/2006 11:50:00 6.9 0.8 8.8 4.6 6.9 0.7 9.1 4.6 6.9 0.8 9.1 4.2 150 7 146 165 3.2 0 3.5 3 11/27/2006 12:00:00 8.7 1 11.1 5.7 8.7 1 11.1 6.1 8.3 1.1 10.7 4.6 139 7 137 165 3.3 0 3.5 3.3 11/27/2006 12:10:00 8.8 1 11.5 6.5 8.7 1 11.1 6.5 8.9 1 11.5 6.8 152 6 154 165 3.3 0 3.5 3.3 11/27/2006 12:20:00 6.7 1 9.1 4.9 6.7 1 9.1 4.6 6.6 0.8 9.1 4.9 146 12 128 165 3.2 0 3.5 3.3 11/27/2006 12:30:00 8.9 0.9 11.5 6.5 8.8 0.9 11.5 6.5 8.8 0.9 11.1 6.1 147 7 143 165 3.3 0 3.5 3.3 11/27/2006 12:40:00 7.1 1 10.7 5.3 7.1 1 10.7 5.3 7.1 1 11.1 5.3 151 6 155 165 3.3 0 3.5 3.3 11/27/2006 12:50:00 8 1 10.7 6.1 7.9 1 10.7 5.7 8 1 10.7 5.3 149 5 150 165 3.3 0 3.5 3.3 11/27/2006 13:00:00 7.9 1.1 11.5 5.7 7.8 1.1 11.5 5.7 7.9 1 10.7 5.7 148 6 140 165 3.3 0 3.5 3.3 11/27/2006 13:10:00 7.6 0.8 9.9 5.3 7.5 0.8 9.9 5.3 7.8 0.9 10.3 5.7 151 7 150 165 3.2 0 3.5 3.3 11/27/2006 13:20:00 7.7 1.1 10.7 5.3 7.7 1.1 10.7 5.3 7.6 1 10.7 4.9 148 11 143 165 3.3 0 3.5 3 11/27/2006 13:30:00 7.3 1 9.9 5.3 7.2 1 9.9 5.3 7.2 0.8 9.5 5.3 147 8 137 165 3.2 0 3.5 3.3 11/27/2006 13:40:00 9.5 0.8 11.5 7.6 9.5 0.8 11.5 7.2 9.3 0.9 11.1 6.1 143 6 150 165 3.5 0 3.5 3.3 11/27/2006 13:50:00 9.2 0.8 11.5 7.2 9.2 0.8 11.5 7.6 9 0.9 11.1 6.5 144 6 152 165 3.5 0 3.5 3.5 11/27/2006 14:00:00 9.5 0.8 11.8 6.8 9.5 0.9 11.8 6.5 9.2 1 11.1 5.7 140 7 141 165 3.5 0 3.5 3.3 11/27/2006 14:10:00 9.5 0.8 11.1 7.2 9.5 0.8 11.5 6.8 9.3 0.8 11.1 6.8 143 5 145 165 3.4 0 3.5 3.3 11/27/2006 14:20:00 9.4 0.8 11.1 6.8 9.4 0.8 11.5 6.8 9.3 0.8 11.1 7.2 145 4 144 165 3.4 0 3.5 3.3 11/27/2006 14:30:00 9.3 0.7 11.1 6.8 9.3 0.7 11.1 7.2 9.2 0.7 11.1 7.2 145 5 153 165 3.4 0 3.5 3.3 11/27/2006 14:40:00 9.3 0.6 10.7 7.2 9.3 0.6 10.7 7.6 9.2 0.8 10.7 5.7 146 4 139 165 3.4 0 3.5 3.3 11/27/2006 14:50:00 9.2 0.8 11.5 6.8 9.2 0.9 11.5 6.8 9.1 1 11.5 5.7 142 6 135 165 3.4 0 3.5 3.3 11/27/2006 15:00:00 9.6 0.7 11.1 7.6 9.7 0.7 11.1 7.6 9.4 0.8 10.7 6.8 140 6 135 165 3.3 0 3.5 3.3 11/27/2006 15:10:00 8.7 0.7 10.3 6.5 8.7 0.7 10.3 6.8 8.6 0.7 10.3 6.1 142 6 136 165 3.3 0 3.5 3.3 11/27/2006 15:20:00 8.4 0.7 11.1 6.8 8.4 0.7 10.7 6.8 8.5 0.7 10.7 6.5 143 5 145 165 3.3 0 3.5 3.3 11/27/2006 15:30:00 9.2 0.7 11.1 7.2 9.2 0.8 11.1 6.8 8.9 0.9 10.3 5.7 138 6 135 165 3.3 0 3.5 3.3 11/27/2006 15:40:00 10 0.8 11.5 7.6 10 0.9 11.5 7.6 10 0.9 11.8 7.2 143 4 133 165 3.3 0 3.5 3.3 11/27/2006 15:50:00 9.5 0.9 11.8 6.5 9.5 0.9 11.5 6.8 9.3 0.9 11.5 6.5 141 5 141 165 3.3 0 3.5 3.3 11/27/2006 16:00:00 9.5 1 12.2 6.5 9.5 1 12.2 6.5 9.3 1 11.5 6.5 140 6 129 165 3.4 0 3.5 3.3 11/27/2006 16:10:00 8.6 1 10.7 6.1 8.5 1 10.7 6.5 8.5 1 10.7 5.7 143 7 145 165 3.4 0 3.5 3.3 11/27/2006 16:20:00 8.8 1 11.5 6.1 8.9 1 11.5 6.5 8.7 1 11.5 6.5 136 6 134 165 3.3 0 3.5 3.3 11/27/2006 16:30:00 8.4 0.8 9.9 5.3 8.4 0.8 10.3 4.9 8.2 0.8 9.9 5.3 138 8 129 165 3.3 0 3.5 3.3 11/27/2006 16:40:00 8.5 0.8 10.3 6.5 8.5 0.8 10.3 5.7 8.2 0.8 10.3 6.1 135 5 140 165 3.4 0 3.5 3.3 11/27/2006 16:50:00 8.6 0.8 10.3 6.1 8.6 0.7 10.7 5.7 8.4 0.8 10.3 6.1 138 6 136 165 3.4 0 3.5 3.3 11/27/2006 17:00:00 8.2 0.8 10.3 5.7 8.2 0.8 9.9 5.7 8 0.8 10.3 5.7 139 6 133 165 3.4 0 3.5 3.3 11/27/2006 17:10:00 9.1 0.8 11.1 7.2 9.2 0.9 11.5 7.2 9 1 10.7 6.8 138 6 139 165 3.4 0 3.5 3.3 11/27/2006 17:20:00 9.5 0.9 12.6 6.8 9.5 0.9 13 6.8 9.2 1 11.8 6.1 137 8 135 165 3.5 0 3.5 3.3 11/27/2006 17:30:00 9.1 0.8 11.5 7.6 9.2 0.8 11.5 7.2 8.9 0.8 11.1 6.5 138 6 142 165 3.5 0 3.5 3.3 11/27/2006 17:40:00 9.7 1 12.2 6.8 9.8 1 12.2 6.5 9.5 1.1 12.6 6.5 136 7 135 165 3.5 0 3.5 3.3 11/27/2006 17:50:00 10.8 1.3 13.7 7.6 10.9 1.3 14.1 7.6 10.5 1.4 13.7 7.2 139 7 154 165 3.5 0 3.5 3.3 11/27/2006 18:00:00 10.1 1 13.3 7.6 10.1 1.1 13.3 6.8 9.9 1.1 13.3 7.2 141 7 142 165 3.4 0 3.5 3.3 11/27/2006 18:10:00 11.1 1.2 13.3 8 11.1 1.2 13.3 7.6 11 1.2 13.3 7.6 142 5 147 165 3.5 0 3.5 3.3 11/27/2006 18:20:00 10 0.9 12.2 7.2 10.1 1 12.2 7.2 9.8 1.1 12.2 6.8 140 7 138 165 3.4 0 3.5 3.3 11/27/2006 18:30:00 10.3 1.5 14.1 6.8 10.3 1.5 14.1 6.8 10 1.6 14.5 6.5 140 6 139 165 3.3 0 3.5 3.3 11/27/2006 18:40:00 12.2 1.1 14.1 8.8 12.2 1.1 14.1 8.8 12.1 1.1 14.1 9.1 142 6 141 165 3.3 0 3.5 3.3 11/27/2006 18:50:00 12.6 1.1 15.3 9.1 12.6 1.1 15.3 9.9 12.3 1.2 14.9 9.5 140 5 140 165 3.2 0 3.5 3.3 11/27/2006 19:00:00 12.3 0.8 14.9 10.3 12.4 0.8 14.9 9.9 12.2 1 15.3 9.5 142 6 142 165 3.2 0 3.5 3.3 11/27/2006 19:10:00 12.1 1.2 15.3 9.1 12.1 1.2 15.3 9.1 11.9 1.3 15.3 8.4 143 6 139 165 3.2 0 3.5 3.3 11/27/2006 19:20:00 13.3 1.2 16.1 9.5 13.3 1.2 16.1 9.5 12.9 1.3 16.1 8.8 138 7 137 165 3 0 3.3 3 11/27/2006 19:30:00 12.6 1.2 16.1 9.5 12.7 1.2 16.1 9.1 12.4 1.2 16.1 8.8 141 6 139 165 3.1 0 3.3 3 11/27/2006 19:40:00 12.2 1.1 14.9 9.1 12.2 1.1 15.3 9.1 11.9 1.1 14.9 8.8 138 7 137 165 3.1 0 3.3 3 11/27/2006 19:50:00 13.2 1.1 16.4 10.3 13.3 1.1 16.1 10.3 12.7 1.2 15.6 9.5 139 6 143 165 3 0 3.3 2.8 11/27/2006 20:00:00 11.8 1.3 15.6 8.4 11.8 1.3 15.6 8.4 11.5 1.3 14.5 8.4 135 7 141 165 3 0 3.3 3 11/27/2006 20:10:00 11.9 1.4 15.3 8 12 1.4 16.1 8.4 11.7 1.5 16.1 8 138 8 121 165 3 0 3.3 2.8 11/27/2006 20:20:00 11.7 1.1 14.1 8.8 11.8 1.1 14.1 8.8 11.4 1.1 14.1 8.8 140 7 135 165 3 0 3.3 2.8 11/27/2006 20:30:00 11.4 1.3 14.1 8 11.4 1.3 14.5 8 11.2 1.5 14.9 7.2 143 5 145 165 3 0 3.3 2.8 11/27/2006 20:40:00 12.3 0.7 14.1 9.9 12.4 0.8 14.5 9.5 12.2 0.8 14.5 9.5 143 6 151 165 3 0 3.3 2.8 11/27/2006 20:50:00 12.5 0.8 14.5 10.3 12.6 0.8 14.5 10.3 12.5 0.9 15.6 9.1 144 4 144 165 2.9 0 3 2.8 11/27/2006 21:00:00 11.3 1 13.7 8 11.4 1 13.7 9.1 11.1 1 13.7 9.1 141 5 135 165 3 0 3.3 2.8 11/27/2006 21:10:00 11.5 0.9 14.1 8.8 11.5 0.9 14.1 8.8 11.4 0.9 13 9.1 148 4 140 165 3 0 3 2.8 11/27/2006 21:20:00 10.8 0.9 13.7 7.2 10.8 0.9 13.7 8 10.7 1.1 13.3 7.6 145 8 145 165 3 0 3.3 2.8 11/27/2006 21:30:00 10.4 0.8 13 8 10.4 0.8 12.6 8 10.2 0.9 12.6 6.8 144 6 143 165 2.9 0 3 2.8 11/27/2006 21:40:00 10.9 1.7 14.1 7.6 10.9 1.7 14.1 7.6 10.6 1.7 14.5 6.5 137 8 132 165 2.9 0 3 2.8 11/27/2006 21:50:00 11.8 0.9 14.5 9.9 11.8 0.9 14.9 9.9 11.7 0.8 14.5 9.5 145 6 138 165 2.9 0 3 2.8 11/27/2006 22:00:00 11.8 1.2 14.9 8.8 11.9 1.2 14.9 8 11.4 1.2 14.1 8 138 6 130 165 2.7 0 2.8 2.6 11/27/2006 22:10:00 11.2 0.8 13.7 9.5 11.3 0.8 13.7 9.1 10.8 1.1 13.3 7.6 135 7 138 165 2.7 0 2.8 2.6 11/27/2006 22:20:00 10.7 1 14.1 8.4 10.7 1 14.1 8.4 10.5 1.1 14.1 7.6 139 8 150 165 2.8 0 3 2.6 11/27/2006 22:30:00 10.3 1.2 12.6 6.8 10.4 1.3 13.3 6.8 10.1 1.2 13.3 6.5 135 7 150 165 2.8 0 3 2.6 11/27/2006 22:40:00 10.5 1.5 14.1 7.2 10.6 1.5 14.5 6.8 10.1 1.7 14.1 5.7 134 6 138 165 2.7 0 2.8 2.6 11/27/2006 22:50:00 11.9 0.9 14.5 9.9 12 0.9 14.5 9.9 11.5 1.1 14.5 8.8 137 7 140 165 2.7 0 2.8 2.6 11/27/2006 23:00:00 11.1 1 13.3 8 11.2 1 14.1 8 10.9 1.1 13.3 8.4 140 8 144 165 2.7 0 2.8 2.6 11/27/2006 23:10:00 10.8 1.1 13.7 8.4 10.9 1.1 13.7 7.6 10.2 1.3 13.3 5.7 138 8 138 165 2.9 0 3 2.8 11/27/2006 23:20:00 12.9 1.1 16.1 10.3 13 1.1 16.4 9.9 12.5 1.3 15.6 8.4 135 6 134 165 2.8 0 3 2.6 11/27/2006 23:30:00 11.2 1.2 14.1 7.2 11.3 1.2 14.1 7.2 10.9 1.2 13.7 7.6 135 7 139 165 2.7 0 2.8 2.6 11/27/2006 23:40:00 11 1.1 14.1 7.2 11.1 1.2 14.1 6.8 10.6 1.3 13.7 7.6 134 7 139 165 2.8 0 3 2.6 11/27/2006 23:50:00 11.3 1.2 14.1 8 11.4 1.3 14.5 8.4 11 1.3 14.1 7.2 135 6 139 165 2.7 0 2.8 2.6 11/28/2006 00:00:00 10.1 1.4 14.9 6.8 10.2 1.5 15.3 6.8 9.7 1.3 14.9 6.1 130 8 126 165 2.7 0 2.8 2.6 11/28/2006 00:10:00 12.3 1.1 15.3 8.8 12.5 1.1 15.3 9.1 12.1 1.3 15.3 8.4 128 6 122 165 2.7 0 2.8 2.6 11/28/2006 00:20:00 11.6 1 14.1 9.1 11.8 1.1 14.5 9.1 11.4 1 13.7 8.4 124 6 127 165 2.7 0 2.8 2.6 11/28/2006 00:30:00 11.4 1 14.1 9.1 11.6 1 14.5 9.5 11.1 1 14.5 8.4 125 5 126 165 2.7 0 2.8 2.6 11/28/2006 00:40:00 10.6 1 13.7 8 10.9 1 13.7 8 10.3 1.1 13 6.8 123 6 128 165 2.7 0 2.8 2.6 11/28/2006 00:50:00 11.2 1.2 13.7 6.8 11.5 1.3 13.7 7.2 10.9 1.3 14.1 6.8 123 6 117 165 2.6 0 2.8 2.6 11/28/2006 01:00:00 9.9 1 13 7.2 10.1 1 13 7.2 9.6 1 12.2 6.5 121 6 117 165 2.6 0 2.8 2.6 11/28/2006 01:10:00 10.7 1 13.7 7.6 11 1.1 13.7 8 10.4 1.1 13 7.2 122 5 117 165 2.6 0 2.8 2.6 11/28/2006 01:20:00 9.7 0.9 12.2 6.8 10 1 12.2 6.8 9.5 1 11.8 6.8 121 7 126 165 2.5 0 2.8 2.6 11/28/2006 01:30:00 9.4 1 11.8 6.5 9.7 1.1 11.8 6.5 8.9 1 11.5 5.7 113 6 112 165 2.5 0 2.8 2.3 11/28/2006 01:40:00 9.2 1 11.8 6.5 9.4 1 12.2 6.8 8.8 1.1 11.8 5.7 118 7 112 165 2.4 0 2.6 2.3 11/28/2006 01:50:00 9.1 1 11.8 6.1 9.4 1 12.2 6.5 8.7 1 11.8 5.7 118 6 107 165 2.4 0 2.8 2.3 11/28/2006 02:00:00 9.8 1.2 12.6 7.2 10.1 1.2 13 6.8 9.4 1.5 13 6.1 117 7 119 165 2.4 0 2.6 2.3 11/28/2006 02:10:00 10.8 1 13.3 7.6 11.1 1 13.7 7.6 10.4 1.2 14.1 6.8 112 6 108 165 2.1 0.2 2.6 1.8 11/28/2006 02:20:00 9.4 1.1 11.8 6.5 9.6 1.1 11.8 6.5 8.9 1.2 11.5 6.1 113 5 119 165 2.1 0 2.3 1.8 11/28/2006 02:30:00 9.7 0.7 11.5 7.2 10 0.8 11.5 7.6 9.1 1 11.5 5.7 105 5 105 165 2.2 0 2.3 2.1 11/28/2006 02:40:00 9.1 1.4 13 5.3 9.4 1.4 13.7 5.7 8.6 1.5 13.3 5.7 106 8 112 165 2.2 0 2.3 2.1 11/28/2006 02:50:00 10.5 1.5 14.1 6.5 10.7 1.5 14.5 7.2 10 1.6 14.1 6.8 113 6 105 165 2 0.1 2.3 1.8 11/28/2006 03:00:00 9.4 1 11.5 6.5 9.7 1 12.2 6.5 9 1 11.1 6.1 108 6 102 165 2 0 2.3 1.8 11/28/2006 03:10:00 9.9 1 12.6 6.1 10.3 1 13 6.8 9.3 1 13 7.2 106 5 105 165 2 0 2.3 1.8 11/28/2006 03:20:00 9.6 1 12.2 7.2 9.9 1.1 12.6 7.2 9 1.1 12.2 6.1 103 6 113 165 1.9 0 2.3 1.8 11/28/2006 03:30:00 9 1.1 11.1 5.7 9.3 1.1 11.8 6.1 8.4 1 10.7 5.7 103 6 99 165 2 0 2.3 1.8 11/28/2006 03:40:00 8.9 1.3 11.5 5.3 9.2 1.3 11.8 5.3 8.4 1.3 11.1 4.9 98 7 102 165 1.9 0 2.3 1.8 11/28/2006 03:50:00 8.5 1.5 11.5 4.2 8.7 1.6 12.2 3.8 8 1.5 11.5 4.6 98 11 87 165 2 0 2.3 1.8 11/28/2006 04:00:00 10.4 1.5 13.3 5.7 10.7 1.5 13.7 5.7 10 1.6 13.3 5.3 112 9 93 165 1.7 0 1.8 1.6 11/28/2006 04:10:00 9.3 0.8 11.5 6.8 9.6 0.8 11.8 6.5 8.9 0.9 11.1 6.8 114 5 114 165 1.6 0 1.8 1.6 11/28/2006 04:20:00 8.1 1.1 10.7 5.3 8.4 1.1 11.1 5.3 7.6 1.2 11.1 4.9 108 7 106 165 1.7 0 1.8 1.4 11/28/2006 04:30:00 8.4 1 11.5 5.7 8.8 0.9 11.8 6.5 8.2 0.9 11.5 6.1 105 6 102 165 1.5 0 1.8 1.4 11/28/2006 04:40:00 9.4 1.6 13 5.7 9.7 1.6 13 6.1 9.1 1.7 12.6 4.9 101 9 94 165 1.8 0 1.8 1.6 11/28/2006 04:50:00 8.9 1.1 11.1 5.7 9.2 1.1 11.5 6.1 8.4 1.2 11.1 4.9 105 7 107 165 1.7 0 1.8 1.6 11/28/2006 05:00:00 9.3 1.3 11.8 4.9 9.5 1.3 12.2 5.7 8.7 1.2 11.8 5.7 100 7 98 165 1.8 0 1.8 1.8 11/28/2006 05:10:00 9.6 1.2 11.8 6.1 9.8 1.3 12.6 6.1 9.1 1.3 12.6 6.1 109 7 105 165 1.8 0 1.8 1.8 11/28/2006 05:20:00 9.2 1.2 12.6 5.7 9.4 1.2 13 5.7 8.8 1.3 11.8 5.3 112 9 114 165 1.7 0 1.8 1.6 11/28/2006 05:30:00 9.9 1.2 12.2 6.5 10.2 1.2 12.6 6.8 9.5 1.3 12.2 6.1 105 5 96 165 1.5 0 1.8 1.4 11/28/2006 05:40:00 10.2 1.5 13.3 6.5 10.5 1.5 13.7 6.8 9.8 1.6 13 6.1 102 7 100 165 1.4 0 1.6 1.4 11/28/2006 05:50:00 9 1.8 13 4.9 9.3 1.8 13.7 4.9 8.6 1.7 12.6 4.9 104 2 105 165 1.4 0 1.6 1.4 11/28/2006 06:00:00 10.4 1.1 13 6.5 10.8 1.2 13.7 6.5 9.9 1.3 13 6.8 101 6 96 165 1.4 0 1.6 1.4 11/28/2006 06:10:00 9.1 1.1 12.2 6.1 9.5 1.1 12.6 6.5 8.8 1.2 11.8 5.7 96 7 94 165 1.4 0 1.6 1.4 11/28/2006 06:20:00 9 1.1 11.5 5.7 9.4 1.2 12.2 6.5 8.6 1.1 11.1 5.7 93 7 105 165 1.4 0 1.6 1.4 11/28/2006 06:30:00 9.2 1.1 11.5 6.5 9.6 1.1 12.2 6.8 8.9 1 11.1 5.7 96 6 100 165 1.4 0 1.6 1.4 11/28/2006 06:40:00 8.7 1.2 11.5 5.7 9.2 1.2 11.8 6.1 8.5 1.2 11.5 5.7 87 7 97 165 1.4 0 1.6 1.4 11/28/2006 06:50:00 9 1.9 12.6 4.2 9.4 2 13 4.9 8.8 1.8 12.6 4.9 85 8 85 165 1.4 0 1.6 1.4 11/28/2006 07:00:00 9.7 1.2 12.6 6.8 10.1 1.3 13.3 7.2 9.4 1.3 13.3 6.5 90 7 91 165 1.4 0 1.8 1.4 11/28/2006 07:10:00 8.9 1.3 13 4.9 9.3 1.3 13.7 5.3 8.7 1.2 12.2 5.7 83 7 85 165 1.4 0 1.6 1.4 11/28/2006 07:20:00 8.9 1.4 13 5.7 9.3 1.5 13.3 6.1 8.7 1.3 12.6 5.3 88 6 84 165 1.4 0 1.6 1.4 11/28/2006 07:30:00 9.3 1.5 13.3 6.1 9.7 1.6 14.1 6.8 9.1 1.5 13.3 6.5 85 7 91 165 1.2 0 1.6 0.9 11/28/2006 07:40:00 8.6 1.1 11.5 5.7 9 1.1 12.2 6.1 8.4 1 11.5 5.7 89 7 103 165 1.2 0 1.4 1.1 11/28/2006 07:50:00 8.6 1.2 12.2 5.3 9.1 1.2 12.6 5.7 8.5 1.3 11.8 4.9 82 8 81 165 1.2 0 1.4 1.1 11/28/2006 08:00:00 8.4 1.4 11.8 5.7 8.8 1.5 12.2 6.1 8.2 1.4 11.8 4.9 80 7 80 165 1.2 0 1.4 0.9 11/28/2006 08:10:00 8.8 1.6 12.2 4.9 9.2 1.7 12.6 5.3 8.6 1.6 11.8 4.9 80 8 74 165 1.2 0 1.4 1.1 11/28/2006 08:20:00 8.7 1.2 11.5 5.7 9.1 1.3 12.2 6.1 8.5 1.2 11.5 6.1 82 7 80 165 1.2 0 1.4 0.9 11/28/2006 08:30:00 7.4 1.1 10.3 4.9 7.8 1.2 10.7 5.3 7.4 1.1 10.3 5.3 78 8 88 165 1.2 0 1.4 1.1 11/28/2006 08:40:00 7.3 1.3 11.1 4.2 7.6 1.3 11.5 4.6 7.2 1.2 9.9 4.2 72 10 71 165 1.3 0 1.6 1.4 11/28/2006 08:50:00 7.6 1.1 11.1 4.9 7.9 1.1 11.1 5.3 7.6 1.1 10.7 5.3 70 9 54 165 1.2 0 1.4 1.4 11/28/2006 09:00:00 7.5 1.1 10.3 4.9 7.7 1.2 10.7 4.9 7.4 1.2 11.5 4.9 68 11 63 165 1.3 0 1.4 1.4 11/28/2006 09:10:00 8.1 1.3 13 5.3 8.4 1.4 13.7 5.3 8 1.4 12.6 5.3 78 10 85 165 1.4 0 1.6 1.4 11/28/2006 09:20:00 9.2 1.5 13 6.1 9.7 1.5 13.3 5.7 9.1 1.5 13 4.9 79 10 89 165 1.3 0 1.6 1.1 11/28/2006 09:30:00 9 1.4 12.6 5.7 9.4 1.5 13 6.1 9 1.4 12.6 5.3 78 9 90 165 1.2 0 1.4 1.1 11/28/2006 09:40:00 9 1.4 12.2 5.3 9.3 1.5 12.6 5.3 8.8 1.4 12.2 5.7 71 8 85 165 1.2 0 1.4 1.1 11/28/2006 09:50:00 8.2 1.1 11.5 5.3 8.5 1.1 11.5 5.7 8.1 1.1 11.5 5.3 70 9 55 165 1.2 0 1.4 1.1 11/28/2006 10:00:00 8.7 1.2 12.6 5.7 8.9 1.3 12.6 6.1 8.3 1.2 11.1 5.7 69 9 64 165 1.2 0 1.4 1.1 11/28/2006 10:10:00 7.6 1.5 12.2 4.2 7.8 1.7 12.2 3.8 7.4 1.4 11.5 4.2 71 11 88 165 1.2 0 1.4 0.9 11/28/2006 10:20:00 7.9 1.2 11.1 5.3 8.1 1.3 11.5 5.3 7.8 1.1 11.1 4.9 67 9 79 165 1.2 0 1.4 0.9 11/28/2006 10:30:00 9 1.1 11.8 5.3 9.3 1.1 11.8 5.7 8.9 1.1 11.5 5.7 71 8 60 165 1.2 0 1.4 1.1 11/28/2006 10:40:00 8.4 1.3 12.2 4.9 8.7 1.3 12.2 5.3 8.3 1.2 11.5 5.3 72 9 77 165 1.2 0 1.4 1.1 11/28/2006 10:50:00 7.6 1.1 10.7 4.6 7.8 1.2 11.5 4.9 7.4 1.2 10.7 4.6 68 10 82 165 1.2 0 1.4 1.1 11/28/2006 11:00:00 7 1.5 11.5 3.8 7.3 1.6 11.5 4.2 6.8 1.3 10.7 4.2 71 8 55 165 1.2 0 1.4 0.9 11/28/2006 11:10:00 6.2 1.2 9.1 4.2 6.4 1.2 9.1 4.2 6.2 1.1 9.1 4.2 70 10 75 165 1.2 0 1.6 1.1 11/28/2006 11:20:00 6.7 1.2 9.5 4.2 6.9 1.3 10.3 4.2 6.7 1.2 9.9 4.2 65 9 78 165 1.2 0 1.6 1.1 11/28/2006 11:30:00 8.1 1 11.1 5.7 8.4 1 11.1 5.3 8 1 10.3 5.3 68 8 81 165 1.3 0 1.4 1.4 11/28/2006 11:40:00 7.2 1.1 10.7 4.2 7.4 1.2 10.7 4.2 7.1 1.1 9.9 4.6 64 10 74 165 1.4 0 1.6 1.4 11/28/2006 11:50:00 6.8 1.1 10.7 4.6 6.9 1.2 11.1 4.6 6.6 1.2 11.1 4.2 61 11 56 165 1.3 0 1.4 1.4 11/28/2006 12:00:00 7.9 1.5 11.5 3.8 8.2 1.6 11.8 4.6 7.9 1.5 11.5 4.2 70 12 68 165 1.4 0 1.6 1.4 11/28/2006 12:10:00 7.3 1 10.7 4.6 7.6 1.1 11.1 4.6 7.2 1 10.3 4.2 75 9 68 165 1.4 0 1.6 1.4 11/28/2006 12:20:00 7.2 1.1 9.9 4.6 7.5 1.1 10.3 4.9 7.1 1.1 9.9 4.9 76 10 77 165 1.4 0 1.6 1.4 11/28/2006 12:30:00 7.2 1 9.9 4.6 7.5 1 10.3 4.6 7.1 1 9.9 4.9 75 8 89 165 1.4 0 1.6 1.4 11/28/2006 12:40:00 7.2 1.2 10.3 4.2 7.5 1.2 10.7 4.6 7.2 1 9.9 4.9 70 9 74 165 1.4 0 1.6 1.4 11/28/2006 12:50:00 7.3 1 9.5 4.9 7.6 1 9.9 4.9 7.3 0.9 9.5 4.9 73 8 78 165 1.4 0 1.6 1.4 11/28/2006 13:00:00 7.7 1.2 10.3 4.2 8 1.3 10.7 4.6 7.5 1.2 9.9 4.2 72 8 81 165 1.4 0 1.6 1.4 11/28/2006 13:10:00 7.1 0.9 9.5 4.9 7.3 0.9 9.9 4.9 7.1 1 9.5 4.9 68 8 54 165 1.4 0 1.6 1.4 11/28/2006 13:20:00 7.3 1 9.5 4.6 7.5 1 10.3 4.6 7.3 1 9.9 4.6 75 9 88 165 1.4 0 1.6 1.4 11/28/2006 13:30:00 6.8 1.1 10.3 4.6 7.1 1.2 10.3 4.2 6.8 1.1 9.9 4.2 70 8 79 165 1.4 0 1.6 1.4 11/28/2006 13:40:00 5.8 1.2 8.8 3.4 5.9 1.3 9.1 3.4 5.8 1.2 9.1 3.4 68 8 81 165 1.4 0 1.6 1.4 11/28/2006 13:50:00 6.4 1.2 9.5 2.3 6.4 1.4 9.1 1.9 6.1 1.2 9.1 3 57 11 52 165 1.3 0 1.6 1.1 11/28/2006 14:00:00 7.1 1 9.5 4.9 7 1.1 9.5 4.6 7 1 9.5 4.9 57 8 56 165 1.2 0 1.6 1.1 11/28/2006 14:10:00 5.8 0.7 7.6 4.2 5.7 0.8 8 3.8 5.7 0.7 7.6 3.8 55 7 54 165 1.2 0 1.4 1.1 11/28/2006 14:20:00 7.1 1.2 10.3 4.6 7.1 1.3 10.3 4.2 6.7 1 9.1 4.2 58 8 56 165 1.3 0 1.4 1.1 11/28/2006 14:30:00 5.7 1 8 3 5.6 1.2 8.4 2.3 5.6 1 8 3.4 56 8 61 165 1.2 0 1.6 1.1 11/28/2006 14:40:00 5 1 8.4 2.6 5 1.1 8.4 1.9 5 1 8.4 3 66 10 52 165 1.3 0 1.4 1.1 11/28/2006 14:50:00 6.8 0.9 9.1 4.6 7.1 1 9.5 4.6 6.7 0.9 9.1 4.6 71 9 68 165 1.4 0 1.6 1.4 11/28/2006 15:00:00 6.7 1 9.1 4.2 6.8 1.1 9.1 4.2 6.7 0.9 8.8 4.6 64 8 62 165 1.3 0 1.6 1.4 11/28/2006 15:10:00 6.6 1.2 9.9 3 6.7 1.3 10.3 3.4 6.5 1.2 10.3 3.4 60 8 67 165 1.2 0 1.4 0.9 11/28/2006 15:20:00 7.1 1.2 9.5 3.8 7.2 1.4 10.3 3.8 7.2 1.2 9.9 4.6 57 8 61 165 1.1 0 1.4 0.9 11/28/2006 15:30:00 6.8 1 9.1 3.8 6.7 1.1 9.5 3.4 6.6 1 9.5 3.8 56 9 65 165 0.8 0 1.1 0.4 11/28/2006 15:40:00 6.7 1 9.1 3.8 6.6 1.1 9.5 3.4 6.7 1 9.5 4.2 53 9 52 165 0.4 0.1 0.7 0.2 11/28/2006 15:50:00 6.3 1 9.5 3.8 6.1 1.1 8.8 2.6 6.1 0.9 8.4 3.8 34 9 29 165 0.2 0 0.4 0.2 11/28/2006 16:00:00 6.9 1 9.9 4.6 7 1.2 9.9 4.2 6.7 1 9.5 3.8 54 10 57 165 0.3 0 0.7 0.2 11/28/2006 16:10:00 6.5 1.6 11.1 3 6.5 1.7 11.5 2.3 6.3 1.6 10.7 3.4 57 10 48 165 0.2 0 0.4 0.2 11/28/2006 16:20:00 7.9 1.3 10.3 4.2 7.4 1.5 10.7 3.8 7.7 1.3 10.7 4.2 36 18 47 165 0.3 0 0.7 0.2 11/28/2006 16:30:00 7.3 0.9 9.5 5.3 5.8 1.3 9.5 3 7.2 0.9 9.5 4.6 11 8 16 165 0.2 0 0.4 0.2 11/28/2006 16:40:00 8.8 1.4 12.2 5.7 6.6 1.6 11.5 3.4 8.7 1.5 12.6 5.7 10 7 9 165 0.2 0 0.4 0.2 11/28/2006 16:50:00 9.1 1 12.2 6.8 6.6 1.5 11.8 4.2 9.1 1 11.8 6.5 9 7 16 165 0.2 0 0.4 0.2 11/28/2006 17:00:00 8.5 2.1 12.6 3.8 7.1 1.4 10.7 3.4 8.5 2 13 4.9 16 10 11 165 0.2 0 0.4 0.2 11/28/2006 17:10:00 7.8 1.4 11.1 4.2 7.6 1.4 11.1 4.2 7.8 1.3 11.5 4.6 25 9 36 165 0.4 0 0.7 0.2 11/28/2006 17:20:00 7.7 1 9.9 5.3 5.6 1.6 9.1 2.3 7.5 1 10.3 5.3 10 8 11 165 0.4 0 0.7 0.2 11/28/2006 17:30:00 8.8 1.1 11.5 6.5 6.2 1.4 10.7 2.6 8.7 1.2 11.8 5.7 9 6 18 165 0.2 0 0.7 0.2 11/28/2006 17:40:00 9.3 1.3 12.6 6.5 7 1.4 10.3 4.2 9.3 1.2 12.2 6.5 9 8 9 165 0.3 0 0.7 0.2 11/28/2006 17:50:00 9 1.1 12.6 6.5 7.3 1.5 10.7 3.8 8.9 1.2 11.8 6.1 13 8 5 165 0.2 0 0.4 0.2 11/28/2006 18:00:00 8.8 1.2 12.2 6.5 6.8 1.6 11.1 3.4 8.6 1.3 11.5 6.1 12 8 18 165 0.2 0 0.2 0.2 11/28/2006 18:10:00 7.3 1.3 10.3 3.8 6.5 1.7 10.3 1.9 7.2 1.2 9.9 3.8 19 11 22 165 0.2 0 0.4 0.2 11/28/2006 18:20:00 8.3 1 10.7 5.7 8.1 1.2 10.7 4.2 8.1 1.1 11.1 5.3 26 8 34 165 0.2 0 0.4 0.2 11/28/2006 18:30:00 7.7 1 9.9 4.6 5.3 1.1 8.8 2.6 7.6 1 9.5 4.9 9 9 11 165 0.3 0 0.7 0.2 11/28/2006 18:40:00 8.3 0.8 10.3 6.5 6 1.3 9.5 3.8 8.3 0.8 10.7 6.5 10 6 5 165 0.2 0 0.4 -0.1 11/28/2006 18:50:00 9 1.5 13 6.1 7.9 1.7 12.2 3.8 8.7 1.5 13 4.9 19 13 25 165 0.2 0 0.7 -0.1 11/28/2006 19:00:00 9 1.6 12.6 4.6 8.7 1.7 12.2 3.8 8.6 1.6 12.6 4.2 26 9 20 165 0.2 0 0.7 0.2 11/28/2006 19:10:00 9.7 1.6 13.7 6.1 9.4 1.8 13.7 4.9 9.3 1.7 14.1 5.7 25 10 39 165 0.3 0.1 0.7 0.2 11/28/2006 19:20:00 8.4 1.8 14.5 4.9 8.1 1.9 14.5 3.8 8 1.7 13.7 4.9 28 10 26 165 0.2 0 0.7 0.2 11/28/2006 19:30:00 11.5 1.8 16.1 8 9.5 2.4 15.3 4.6 11.3 2 16.4 6.5 13 6 17 165 0.2 0 0.7 0.2 11/28/2006 19:40:00 9.9 1.1 12.6 7.2 7.6 1.7 12.6 3.8 10 1.2 13.3 6.5 11 7 8 165 0.1 0 0.2 -0.1 11/28/2006 19:50:00 9.2 1.1 12.2 6.5 6.6 1.6 11.1 3.4 9.1 1.3 13.3 5.7 9 9 16 165 0 0 0.2 -0.1 11/28/2006 20:00:00 9 1.7 13.3 5.7 5.8 1.5 9.9 2.3 8.8 1.8 13.3 5.3 7 7 3 165 0.1 0 0.2 -0.1 11/28/2006 20:10:00 9.4 1.2 12.6 6.5 6.1 1.4 10.7 3 9.1 1.2 11.8 6.1 6 7 9 165 0.1 0 0.2 -0.1 11/28/2006 20:20:00 9.8 1.5 14.1 6.1 6.7 1.6 10.7 3 9.7 1.5 13.7 5.7 4 8 6 165 0.1 0 0.2 -0.1 11/28/2006 20:30:00 10.1 1.5 13.3 6.5 6.3 1.5 10.7 3 10.1 1.6 14.5 6.5 5 6 9 165 0.1 0 0.2 -0.1 11/28/2006 20:40:00 9.7 0.9 12.2 7.2 6.3 1.4 10.3 3.4 9.8 1 13 6.8 8 6 10 165 0 0 0.2 -0.1 11/28/2006 20:50:00 8 1.1 10.7 5.3 5.5 1.2 9.1 3 8.1 1.2 11.5 5.3 10 6 360 165 0.1 0 0.2 -0.1 11/28/2006 21:00:00 8.5 1.4 12.2 5.7 5.4 1.3 9.9 3 8.4 1.3 12.6 5.3 3 7 353 165 0.1 0 0.2 -0.1 11/28/2006 21:10:00 8.5 0.9 10.3 6.5 5.6 1.4 9.9 3 8.4 0.9 11.1 6.1 4 7 10 165 0 0 0.2 -0.1 11/28/2006 21:20:00 7.6 0.9 9.9 5.3 4.7 1.2 8.4 2.3 7.5 1 10.7 4.9 4 7 15 165 -0.2 0.1 0.2 -0.3 11/28/2006 21:30:00 7.6 1 10.7 5.3 5 1.4 8.8 2.6 7.5 1.1 9.9 4.9 358 6 351 165 -0.2 0 -0.1 -0.3 11/28/2006 21:40:00 8.1 1.1 11.1 5.3 5.6 1.5 9.1 3 7.7 1.2 10.7 4.6 359 8 349 165 -0.2 0 -0.1 -0.3 11/28/2006 21:50:00 9.1 1.2 12.6 6.8 6.1 1.7 12.2 2.6 8.8 1.3 12.6 5.7 357 6 353 165 -0.3 0 -0.1 -0.5 11/28/2006 22:00:00 9.3 1 11.8 6.8 6.8 1.5 9.9 3.8 9.1 1.1 11.8 6.8 355 7 360 165 -0.3 0 -0.1 -0.3 11/28/2006 22:10:00 8.8 1 11.8 6.1 7.9 1.3 11.5 3.8 8.5 1.1 11.5 5.7 346 8 350 165 -0.3 0 -0.1 -0.3 11/28/2006 22:20:00 7.8 1.3 11.5 4.2 7 1.7 11.5 3 7.7 1.3 11.1 4.6 346 11 352 165 -0.3 0 -0.1 -0.5 11/28/2006 22:30:00 10 1.2 14.1 6.5 8.1 2.2 12.2 3.4 10 1.4 14.5 6.5 354 9 354 165 -0.3 0 -0.1 -0.5 11/28/2006 22:40:00 9.1 1.1 11.8 5.7 8 1.8 11.5 3.8 8.9 1.2 11.8 5.7 348 8 342 165 -0.3 0 -0.1 -0.3 11/28/2006 22:50:00 8.6 1 11.5 6.1 7.2 1.5 10.7 3.4 8.3 1.1 12.2 5.7 350 11 342 165 -0.3 0 -0.1 -0.5 11/28/2006 23:00:00 8.7 0.8 11.5 6.5 7.5 1.5 10.7 4.2 8.8 1 12.2 6.5 352 12 18 165 -0.3 0 -0.1 -0.5 11/28/2006 23:10:00 8 1 10.7 5.7 6.8 1.5 10.7 2.6 7.9 1.1 11.5 5.3 348 13 344 165 -0.3 0 -0.1 -0.5 11/28/2006 23:20:00 6.5 1.2 9.9 3.4 5.2 1.5 8.8 1.9 6.5 1.2 10.3 3.4 354 13 5 165 -0.2 0 -0.1 -0.3 11/28/2006 23:30:00 6.3 1.6 10.3 3.4 6.1 1.7 9.9 2.3 6.3 1.5 10.3 4.2 332 16 320 165 -0.2 0 0.2 -0.3 11/28/2006 23:40:00 8.3 1.2 11.1 5.7 8.2 1.1 10.7 5.7 8.4 1.2 11.8 4.9 336 9 343 165 -0.2 0 0.2 -0.3 11/28/2006 23:50:00 7.5 1 10.3 5.7 6.9 1.5 9.9 2.6 7.6 0.9 10.7 5.7 339 15 335 165 -0.2 0 -0.1 -0.3 11/29/2006 00:00:00 7.1 1 9.5 4.6 6.9 1.3 9.5 2.3 7.1 1 9.5 4.9 335 13 318 165 -0.3 0 0.2 -0.5 11/29/2006 00:10:00 8.7 1.2 11.5 4.6 8.6 1.2 11.1 4.9 8 1.2 11.1 4.9 316 9 330 165 -0.2 0 -0.1 -0.5 11/29/2006 00:20:00 8.5 1.1 11.1 5.7 8.4 1.1 10.7 4.9 7.9 1.2 10.3 4.6 322 13 5 165 -0.4 0 -0.1 -0.5 11/29/2006 00:30:00 8.5 1.2 11.5 3.8 8.4 1.2 11.8 3.4 7.6 1.1 10.7 4.2 314 10 306 165 -0.5 0.1 -0.3 -0.8 11/29/2006 00:40:00 9.5 1 12.6 5.7 9.4 1 12.2 6.5 8.2 1.4 11.8 4.6 311 11 304 165 -0.4 0 -0.3 -0.8 11/29/2006 00:50:00 10.3 1.4 13.7 6.5 10.2 1.4 14.1 6.1 8.9 1.3 13 5.7 311 9 310 165 -0.3 0 -0.1 -0.5 11/29/2006 01:00:00 10.6 1 14.5 7.2 10.5 1 14.5 8 9.2 1.3 13 5.3 310 8 295 165 -0.3 0.1 -0.1 -0.5 11/29/2006 01:10:00 11.2 1.3 14.5 6.1 11 1.2 14.5 7.2 9.8 1.7 14.1 5.7 311 10 305 165 -0.2 0 0.2 -0.5 11/29/2006 01:20:00 10.8 1.2 14.1 7.2 10.7 1.1 14.1 7.2 9.8 1.2 12.2 6.5 314 8 300 165 -0.1 0 0.2 -0.3 11/29/2006 01:30:00 11.7 1 13.7 8.8 11.5 1 13.7 8.8 9.4 1.2 13 5.7 308 7 298 165 -0.2 0.1 0.2 -0.5 11/29/2006 01:40:00 12.2 1.1 15.6 8.8 12 1 16.1 8.8 10.2 1.4 15.3 6.5 308 8 301 165 -0.3 0 -0.1 -0.5 11/29/2006 01:50:00 12.5 1.3 15.6 9.5 12.3 1.2 15.6 9.1 11.2 1.5 14.9 7.2 314 6 308 165 -0.3 0 -0.1 -0.5 11/29/2006 02:00:00 12.2 1 14.9 9.5 12 1 14.5 9.1 10.5 1.2 13.7 7.2 311 5 308 165 -0.3 0 -0.1 -0.5 11/29/2006 02:10:00 11.2 1 14.5 9.1 11 0.9 14.9 9.1 9.6 1.2 14.1 7.2 311 5 301 165 -0.4 0 -0.1 -0.5 11/29/2006 02:20:00 10.3 1.1 13.7 8 10.2 1 13.3 7.6 8.2 1.2 12.6 5.7 306 5 302 165 -0.3 0 -0.1 -0.8 11/29/2006 02:30:00 10.4 1.1 13.3 7.6 10.2 1.1 13 7.6 8.4 1.5 12.6 5.3 308 7 302 165 -0.5 0 -0.3 -0.8 11/29/2006 02:40:00 11.1 1 13.7 8.4 10.9 1 13.7 8.4 9.1 1.2 12.2 6.1 310 7 316 165 -0.5 0 -0.3 -0.8 11/29/2006 02:50:00 10.8 1.1 14.1 8 10.7 1.1 13.7 8 9 1.1 12.2 5.7 309 6 301 165 -0.5 0 -0.3 -0.8 11/29/2006 03:00:00 11.6 1.2 14.5 8.8 11.4 1.1 14.1 8.4 10.6 1.3 14.1 7.2 316 7 322 165 -0.4 0.1 -0.1 -0.8 11/29/2006 03:10:00 12.5 1.1 14.9 9.1 12.3 1.1 14.9 9.1 10.8 1.3 14.9 7.2 312 5 316 165 -0.5 0 -0.1 -0.8 11/29/2006 03:20:00 13.1 1.2 16.4 9.1 12.9 1.1 16.1 9.5 12.1 1.2 15.3 8.4 317 6 313 165 -0.6 0 -0.5 -0.8 11/29/2006 03:30:00 12.6 1.3 15.6 9.9 12.4 1.2 15.6 9.9 11.1 1.2 14.1 8.4 314 5 311 165 -0.7 0 -0.5 -0.8 11/29/2006 03:40:00 13.6 1.2 17.9 10.7 13.5 1.2 17.2 10.7 12.4 1.3 16.1 9.1 315 5 315 165 -0.8 0 -0.5 -0.8 11/29/2006 03:50:00 15.4 1.1 19.1 12.6 15.2 1.1 19.1 12.6 14.4 1.5 17.9 9.5 317 6 316 165 -0.4 0 -0.3 -0.5 11/29/2006 04:00:00 15.5 1.1 19.1 11.5 15.4 1 19.1 11.8 14.7 1.1 17.6 11.1 317 4 319 165 -0.5 0 -0.1 -0.8 11/29/2006 04:10:00 16.1 1.2 18.7 12.2 16 1.2 18.3 12.6 15.7 1.3 19.1 11.8 321 5 318 165 -0.5 0 -0.3 -0.8 11/29/2006 04:20:00 17.2 1.3 19.9 13 17.1 1.3 19.9 13.3 17 1.4 20.6 12.6 320 4 318 165 -0.5 0 -0.3 -0.5 11/29/2006 04:30:00 17.4 1.2 20.2 12.2 17.4 1.2 20.2 12.2 17.2 1.4 21 12.2 322 5 319 165 -0.4 0 -0.3 -0.5 11/29/2006 04:40:00 18.5 1.3 21.8 15.6 18.6 1.3 21.8 15.3 18.2 1.4 21.8 13.3 319 4 324 165 -0.3 0 -0.1 -0.5 11/29/2006 04:50:00 17.9 1.3 21.4 14.5 18.1 1.4 21.4 14.5 17.6 1.5 21.4 13 320 5 326 165 -0.3 0 -0.1 -0.5 11/29/2006 05:00:00 17.5 1.2 20.6 13.7 17.6 1.3 21 13.3 17.4 1.5 21 13 323 5 313 165 -0.2 0 -0.1 -0.5 11/29/2006 05:10:00 15.3 1.3 18.7 11.5 15.4 1.3 18.7 11.8 14.7 1.3 17.9 11.1 319 6 312 165 -0.4 0 -0.1 -0.5 11/29/2006 05:20:00 15.7 1.2 18.7 11.1 15.7 1.2 18.3 11.5 15.3 1.3 18.3 10.7 319 6 319 165 -0.4 0 -0.3 -0.8 11/29/2006 05:30:00 16.3 1.2 20.6 12.6 16.4 1.3 20.6 12.6 16 1.6 19.5 10.3 320 6 322 165 -0.3 0.1 -0.1 -0.5 11/29/2006 05:40:00 16 1.2 19.1 12.6 16 1.2 18.7 12.2 15.8 1.3 19.5 12.2 320 5 322 165 -0.3 0 -0.3 -0.5 11/29/2006 05:50:00 17 1.2 20.2 13.7 17.1 1.2 20.2 13.3 16.2 1.5 20.2 12.2 316 5 325 165 -0.3 0 -0.1 -0.5 11/29/2006 06:00:00 16.3 1.2 19.1 12.2 16.4 1.2 19.1 12.2 15.7 1.1 18.3 11.8 316 5 316 165 -0.3 0 -0.1 -0.5 11/29/2006 06:10:00 16.9 1 19.1 13.7 17 1 19.5 14.5 16.2 1.2 19.1 12.6 315 5 313 165 -0.3 0 -0.1 -0.5 11/29/2006 06:20:00 17.1 1.1 20.2 14.5 17.2 1 19.9 14.5 16.8 1.2 19.9 13.3 321 7 323 165 -0.2 0 -0.1 -0.3 11/29/2006 06:30:00 15.7 1.7 19.5 11.8 15.7 1.7 19.5 11.5 15.6 1.8 19.9 11.1 323 8 323 165 0 0 0.2 -0.1 11/29/2006 06:40:00 14.1 1.2 17.2 11.1 14.1 1.2 17.6 10.7 13.8 1.4 17.9 10.7 322 8 325 165 0 0 0.2 -0.1 11/29/2006 06:50:00 14.3 1.7 18.7 9.5 14.3 1.7 18.7 9.5 14 1.7 19.1 9.1 322 7 327 165 0.1 0 0.2 -0.1 11/29/2006 07:00:00 15.3 1.5 19.9 11.8 15.4 1.5 20.2 11.5 15.1 1.7 19.9 10.7 320 6 325 165 0.1 0 0.2 -0.1 11/29/2006 07:10:00 15.3 1.3 18.7 11.5 15.4 1.4 19.1 11.1 15 1.5 19.1 11.1 318 6 319 165 0.2 0 0.2 -0.1 11/29/2006 07:20:00 15.8 1.3 19.5 11.8 15.9 1.4 19.9 11.8 15.7 1.4 19.1 10.7 322 6 314 165 0.2 0 0.4 0.2 11/29/2006 07:30:00 15.6 1.2 19.9 12.2 15.6 1.2 19.5 12.6 15.3 1.4 19.1 11.1 323 6 310 165 0.2 0 0.7 0.2 11/29/2006 07:40:00 16.1 1.3 19.1 12.2 16.3 1.3 19.5 12.2 15.2 1.3 18.7 11.5 316 8 323 165 0.2 0 0.4 0.2 11/29/2006 07:50:00 17.2 1.3 20.2 13.3 17.3 1.3 20.6 13.3 16.7 1.5 20.6 12.6 318 6 319 165 0.3 0 0.7 0.2 11/29/2006 08:00:00 17.7 1.3 21.4 14.1 17.8 1.3 21.4 13.7 17.6 1.5 21.4 13.3 319 5 319 165 0.5 0 0.7 0.4 11/29/2006 08:10:00 16.5 1.5 20.2 12.6 16.6 1.5 20.2 12.2 16.3 1.7 20.2 12.2 318 6 321 165 0.5 0 0.7 0.2 11/29/2006 08:20:00 16.7 1.3 20.2 13 16.8 1.3 20.6 13.3 16 1.5 19.9 12.2 315 5 319 165 0.5 0 0.7 0.2 11/29/2006 08:30:00 16.1 1.6 19.1 12.2 16.2 1.7 19.1 12.2 15.4 1.7 19.5 11.1 317 6 315 165 0.5 0 0.7 0.2 11/29/2006 08:40:00 14.6 1.3 17.9 10.3 14.5 1.4 17.9 10.3 14.2 1.5 18.3 10.3 319 6 338 165 0.5 0 0.7 0.2 11/29/2006 08:50:00 15.4 1.1 18.7 11.8 15.3 1.1 18.7 11.8 14.7 1.4 19.1 9.1 316 6 314 165 0.5 0 0.9 0.2 11/29/2006 09:00:00 15.8 1.1 18.3 12.2 15.7 1.1 18.3 11.5 14.5 1.2 17.6 10.7 312 5 302 165 0.7 0 0.9 0.7 11/29/2006 09:10:00 14.5 1.6 18.3 9.9 14.3 1.6 18.3 9.9 13.1 1.4 17.2 9.5 312 5 311 165 0.8 0 0.9 0.7 11/29/2006 09:20:00 13 1.1 16.4 10.3 12.8 1.1 16.1 9.9 11.8 1.1 14.9 8.4 314 6 296 165 0.7 0 0.9 0.4 11/29/2006 09:30:00 13.1 1.3 15.6 9.9 12.9 1.3 15.6 9.5 11.9 1.3 16.1 8.4 314 6 316 165 0.8 0 1.1 0.7 11/29/2006 09:40:00 12.1 1.1 15.6 9.1 12 1.1 15.6 9.1 11.3 1.3 15.3 7.6 314 6 307 165 0.9 0 1.4 0.9 11/29/2006 09:50:00 12 1.3 15.6 9.1 11.9 1.3 15.6 8.8 10.7 1.6 15.3 7.2 311 5 308 165 1.2 0 1.4 0.9 11/29/2006 10:00:00 12.8 1 15.6 10.3 12.7 1 15.3 10.3 11 1.3 15.6 7.6 310 5 314 165 1.3 0 1.6 1.1 11/29/2006 10:10:00 12.8 1.1 15.3 9.9 12.7 1.1 14.9 9.5 11.1 1.1 14.1 8 311 5 301 165 1.3 0 1.6 1.1 11/29/2006 10:20:00 12.3 1.1 14.9 9.1 12.1 1.1 14.9 8.8 10.9 1.1 13.3 7.6 312 5 314 165 1.4 0 1.6 1.4 11/29/2006 10:30:00 12.6 1 15.3 9.5 12.5 1 15.3 9.9 11.6 1.2 14.5 8.4 311 5 319 165 1.4 0 1.8 1.4 11/29/2006 10:40:00 13.7 1 16.4 11.1 13.7 1 16.4 11.1 11.9 1.2 14.5 8 310 5 303 165 1.4 0 1.6 1.4 11/29/2006 10:50:00 14.1 0.9 16.1 11.8 14 1 16.4 10.7 11.9 1.3 15.3 8 307 5 301 165 1.4 0 1.6 1.4 11/29/2006 11:00:00 14.4 1.1 16.8 10.7 14.3 1.2 17.2 10.7 11.4 1.4 14.5 8 306 5 301 165 1.7 0 1.8 1.4 11/29/2006 11:10:00 14.1 1 16.1 11.1 14.1 1.1 16.1 10.7 10.1 1 14.1 7.2 302 4 302 165 1.8 0 2.3 1.6 11/29/2006 11:20:00 14.6 1.1 16.8 11.5 14.6 1.1 16.8 11.5 11.1 1.4 14.9 8 304 5 302 165 1.8 0 2.1 1.6 11/29/2006 11:30:00 14.4 1.1 17.2 11.1 14.4 1.2 17.2 11.1 11.6 1.6 16.8 8.4 306 5 302 165 2 0 2.3 1.8 11/29/2006 11:40:00 14.2 1.2 16.8 11.1 14.1 1.2 17.2 11.1 11.9 1.3 15.6 8.4 307 5 309 165 2.1 0 2.3 1.8 11/29/2006 11:50:00 14.5 1.2 16.8 11.1 14.4 1.3 16.8 10.7 12.1 1.4 15.6 8.4 307 5 312 165 2.3 0 2.6 2.1 11/29/2006 12:00:00 14.6 1 16.8 11.5 14.5 1.1 16.8 11.1 11.6 1.6 16.1 8 306 5 304 165 2.3 0 2.8 2.3 11/29/2006 12:10:00 12.7 1.5 15.6 8.8 12.6 1.4 16.1 9.1 10 1.5 13.7 6.5 304 5 307 165 2.4 0 2.8 2.3 11/29/2006 12:20:00 11.9 1.2 15.3 9.1 11.8 1.2 14.5 9.1 9.1 1.3 13.3 6.5 300 6 301 165 2.6 0.1 2.8 1.8 11/29/2006 12:30:00 12 1.3 16.1 8.8 12 1.3 15.6 9.1 9 1.3 13 6.1 300 5 313 165 2.5 0.1 2.8 1.8 11/29/2006 12:40:00 12.3 1.1 14.5 9.1 12.2 1.1 14.5 9.5 9.6 1.1 12.6 6.5 306 5 303 165 2.6 0.1 2.8 1.8 11/29/2006 12:50:00 11.4 1 13.3 9.1 11.3 1 13.7 9.1 8.9 0.9 11.1 6.5 306 6 302 165 2.7 0.1 3 2.1 11/29/2006 13:00:00 11.3 1 13.3 8.4 11.2 1 13.3 8 8.7 1.1 11.8 6.1 306 5 308 165 2.9 0.1 3.3 2.3 11/29/2006 13:10:00 11 0.8 13.3 8.4 11 0.8 13.3 8.8 8 0.9 10.3 6.1 303 5 300 165 2.7 0.2 3 2.3 11/29/2006 13:20:00 10.8 1 13.7 8.4 10.8 1 13.7 8 8.1 1.1 11.1 5.7 303 5 307 165 2.7 0.2 3 2.3 11/29/2006 13:30:00 10.3 0.9 12.2 8.4 10.2 0.9 12.2 8.4 8.9 1 11.5 5.7 310 5 304 165 3 0.1 3.3 2.3 11/29/2006 13:40:00 9.1 1 12.2 6.1 9.1 1.1 11.8 6.1 7.9 1.2 10.7 4.6 310 6 316 165 3.1 0.2 3.5 2.6 11/29/2006 13:50:00 6.9 1 9.5 3.4 6.9 1 9.5 3.4 6 0.9 8.4 3.4 290 9 295 165 2.9 0.1 3.5 2.6 11/29/2006 14:00:00 6.2 1.3 8.8 2.3 6.3 1.2 8.8 3.4 5.4 1 8.4 3.4 291 15 278 165 3 0.1 3.3 2.6 11/29/2006 14:10:00 6.5 1.1 8.4 3.4 6.4 1.1 8.4 2.6 5.2 0.9 6.8 3 304 8 310 165 3.1 0.1 3.5 2.6 11/29/2006 14:20:00 6 0.8 8 4.6 6 0.7 7.6 4.6 4.8 0.8 7.6 3 298 8 289 165 2.9 0 3.3 2.8 11/29/2006 14:30:00 6.2 0.6 7.6 4.6 6.2 0.6 7.2 4.6 4.6 0.5 6.5 3.4 301 5 301 165 2.9 0 3.5 2.8 11/29/2006 14:40:00 5.9 0.7 7.6 4.2 6 0.7 7.6 4.6 4.5 0.5 6.1 3.4 297 6 307 165 2.7 0.1 3 2.3 11/29/2006 14:50:00 7.3 0.8 8.4 5.3 7.4 0.7 8.8 5.7 6.5 0.8 8.4 4.2 290 3 290 165 2.3 0.1 2.8 1.6 11/29/2006 15:00:00 8.7 0.3 9.5 8 8.8 0.3 9.5 8 8 0.6 9.5 6.1 287 3 282 165 2.1 0.1 2.3 1.6 11/29/2006 15:10:00 7.7 0.8 9.1 4.6 7.8 0.8 9.1 5.3 7.1 0.6 8.4 4.9 285 4 287 165 2 0.1 2.3 1.6 11/29/2006 15:20:00 5.6 0.5 7.2 3.4 5.8 0.5 7.2 3.4 5.5 0.6 6.8 3.4 284 4 288 165 2.1 0.2 2.6 1.6 11/29/2006 15:30:00 5.4 0.4 6.1 3.8 5.5 0.5 6.5 4.2 5.2 0.5 6.5 3.8 284 4 282 165 2.6 0.1 2.8 1.8 11/29/2006 15:40:00 4.2 0.4 4.9 3 4.2 0.4 4.9 3 3.5 0.6 5.3 2.3 294 5 284 165 2.7 0.1 3 2.6 11/29/2006 15:50:00 3.3 0.7 4.6 0.7 3.3 0.6 4.6 1.5 3.2 0.5 4.2 1.9 281 12 295 165 2.6 0.1 3.3 2.3 11/29/2006 16:00:00 1.9 0.6 3.4 0.7 1.9 0.6 3.4 0.7 2 0.6 3.4 1.1 285 8 286 165 2.8 0.1 3 2.1 11/29/2006 16:10:00 1.3 0.4 2.3 0.7 1.2 0.4 1.9 0.4 1.6 0.3 2.3 1.1 306 8 321 165 2.7 0 3.3 2.3 11/29/2006 16:20:00 2 0.5 3 0.7 2 0.5 3 0.7 2.3 0.3 3 1.5 329 6 322 165 2.1 0.2 2.8 1.8 11/29/2006 16:30:00 0.5 0.3 1.5 0.4 0.5 0.2 1.5 0.4 1 0.5 1.9 0.4 343 11 8 165 1.8 0 2.1 1.6 11/29/2006 16:40:00 0.7 0.5 2.3 0.4 0.8 0.6 2.3 0.4 0.8 0.4 1.9 0.4 312 41 282 165 1.8 0 1.8 1.6 11/29/2006 16:50:00 1.2 0.4 2.3 0.4 1.5 0.5 2.3 0.4 1.6 0.5 2.6 0.4 250 15 257 165 1.8 0 1.8 1.6 11/29/2006 17:00:00 0.6 0.4 1.9 0.4 0.8 0.5 2.3 0.4 1 0.5 2.3 0.4 191 13 201 165 1.8 0 1.8 1.6 11/29/2006 17:10:00 0.5 0.2 1.5 0.4 0.7 0.4 1.5 0.4 0.8 0.4 1.9 0.4 278 41 326 165 1.8 0.1 1.8 1.6 11/29/2006 17:20:00 0.7 0.4 1.5 0.4 1 0.5 1.9 0.4 1.1 0.3 2.3 0.4 304 14 288 165 2 0 2.3 1.6 11/29/2006 17:30:00 1.3 0.4 2.3 0.4 1.7 0.3 2.3 0.7 1.6 0.2 2.3 1.1 310 7 308 165 1.9 0.1 2.3 1.6 11/29/2006 17:40:00 1.9 0.3 2.6 1.1 2.2 0.3 3 1.5 2.1 0.3 3 1.5 309 9 301 165 2 0 2.3 1.8 11/29/2006 17:50:00 0.9 0.5 1.9 0.4 1.3 0.5 2.3 0.4 1.4 0.6 2.3 0.4 307 11 315 165 1.7 0 2.3 1.4 11/29/2006 18:00:00 0.8 0.5 2.3 0.4 1 0.7 2.3 0.4 1.2 0.7 2.6 0.4 183 82 138 165 1.7 0 1.8 1.4 11/29/2006 18:10:00 0.4 0.1 0.7 0.4 0.5 0.3 1.1 0.4 0.8 0.4 1.5 0.4 315 69 312 165 1.4 0.1 1.8 0.9 11/29/2006 18:20:00 0.4 0.1 0.7 0.4 0.4 0.2 1.1 0.4 0.8 0.4 1.9 0.4 294 33 311 165 0.9 0.1 1.4 0.7 11/29/2006 18:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0.1 0.7 0.4 283 0 165 165 0.8 0 1.1 0.7 11/29/2006 18:40:00 0.5 0.3 1.5 0.4 0.6 0.4 1.9 0.4 0.7 0.5 1.9 0.4 150 43 133 165 0.9 0.2 1.4 0.7 11/29/2006 18:50:00 0.5 0.2 1.1 0.4 0.6 0.3 1.5 0.4 1.1 0.2 1.5 0.7 133 3 133 165 1.3 0 1.6 1.4 11/29/2006 19:00:00 0.6 0.4 1.5 0.4 0.8 0.5 1.9 0.4 1.2 0.5 2.3 0.4 114 2 119 165 1.3 0 1.4 1.1 11/29/2006 19:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.7 0.4 113 0 165 165 1.2 0.1 1.6 0.9 11/29/2006 19:20:00 0.8 0.6 2.3 0.4 0.9 0.7 2.3 0.4 1.1 0.8 2.6 0.4 114 0 114 165 1.2 0.2 1.6 0.9 11/29/2006 19:30:00 1.4 0.4 1.9 0.7 1.7 0.3 2.3 0.7 1.8 0.3 2.3 1.1 127 6 114 165 1.2 0 1.6 0.9 11/29/2006 19:40:00 1.2 0.3 1.9 0.4 1.5 0.3 1.9 0.7 1.6 0.2 2.3 1.1 124 2 128 165 1.2 0 1.4 0.9 11/29/2006 19:50:00 1.8 0.4 2.6 1.1 2 0.4 3 1.1 2.2 0.3 3 1.5 127 2 127 165 1.2 0 1.6 0.9 11/29/2006 20:00:00 2 0.4 2.6 1.1 2.1 0.4 2.6 1.1 2.3 0.4 3 1.5 140 4 139 165 1.2 0.2 1.6 0.9 11/29/2006 20:10:00 2 0.3 2.6 1.1 2.2 0.3 2.6 1.5 2.5 0.2 3 1.9 131 1 130 165 1.1 0 1.8 0.9 11/29/2006 20:20:00 1.9 0.3 2.3 1.1 2 0.3 2.6 1.1 2.3 0.4 3 1.1 143 14 130 165 0.9 0 1.4 0.9 11/29/2006 20:30:00 1.5 0.6 2.6 0.4 1.5 0.5 2.6 0.4 1.9 0.4 3 1.1 164 10 179 165 1.2 0 1.4 0.9 11/29/2006 20:40:00 1.8 0.6 2.6 0.4 1.9 0.6 2.6 0.4 2 0.5 3 0.7 159 8 164 165 1.2 0.1 1.6 0.9 11/29/2006 20:50:00 1.9 0.8 3 0.4 2 0.8 3 0.4 2.3 0.6 3.4 1.1 165 7 175 165 1.5 0 1.8 1.4 11/29/2006 21:00:00 1.2 0.6 2.6 0.4 1.2 0.6 2.6 0.4 1.7 0.4 2.6 1.1 172 8 169 165 1.4 0.1 1.8 1.1 11/29/2006 21:10:00 1.7 0.5 3 0.7 1.7 0.5 3 0.4 1.9 0.5 2.6 1.1 163 6 177 165 1.3 0 1.6 1.1 11/29/2006 21:20:00 2.2 0.7 3.4 1.1 2.2 0.6 3.4 1.1 2.4 0.3 3 1.9 172 6 180 165 1.5 0.1 1.8 1.1 11/29/2006 21:30:00 2.3 0.3 3 1.9 2.3 0.3 3 1.9 2.7 0.3 3.4 2.3 168 8 167 165 0.5 0.2 1.6 0.2 11/29/2006 21:40:00 2.1 0.3 2.6 1.5 2.1 0.2 2.6 1.5 2.3 0.3 3 1.5 163 11 170 165 0.2 0 0.7 -0.1 11/29/2006 21:50:00 2.6 0.3 3.4 1.9 2.7 0.3 3.4 2.3 3.1 0.3 3.8 2.3 156 4 164 165 0.1 0.1 0.4 -0.1 11/29/2006 22:00:00 4.4 1.1 6.5 2.3 4.3 1 6.1 1.9 4.2 1 6.1 2.3 159 10 170 165 0.3 0.1 0.7 0.2 11/29/2006 22:10:00 4.9 0.8 7.2 2.6 4.7 0.7 6.8 3 4.6 0.7 6.8 2.6 176 12 180 165 0.5 0.2 0.9 -0.1 11/29/2006 22:20:00 4.7 0.8 6.5 3 4.6 0.7 6.5 2.6 4.7 0.7 6.1 3 173 9 180 165 0.7 0 1.1 0.4 11/29/2006 22:30:00 5.3 0.5 6.5 4.2 5.1 0.5 6.1 3.8 5.2 0.5 6.5 3.8 171 10 162 165 0.4 0.1 0.9 0.2 11/29/2006 22:40:00 6 0.4 7.2 4.6 5.8 0.4 6.8 4.6 5.7 0.5 6.8 4.2 185 5 188 165 0.5 0 0.7 0.2 11/29/2006 22:50:00 5.6 0.4 6.5 4.2 5.7 0.4 6.5 4.6 5.9 0.4 6.8 4.9 194 3 195 165 0.9 0.1 1.1 0.7 11/29/2006 23:00:00 5.8 0.6 7.6 4.2 5.8 0.6 7.6 4.6 5.9 0.6 7.6 4.2 189 6 193 165 1 0 1.4 0.9 11/29/2006 23:10:00 5.8 0.8 8 4.2 5.6 0.8 7.6 3.8 5.7 0.9 8.4 3.8 183 6 192 165 1 0.1 1.4 0.9 11/29/2006 23:20:00 4.7 0.5 6.1 3 4.6 0.5 5.7 3 4.7 0.5 6.1 3.4 162 10 166 165 0.7 0 0.9 0.7 11/29/2006 23:30:00 5.5 0.7 7.6 3 5.4 0.7 7.6 3.8 5.6 0.6 7.2 3.4 168 14 179 165 0.9 0.1 1.4 0.7 11/29/2006 23:40:00 6.7 1.1 9.1 3.8 6.7 1.1 9.1 3.8 6.6 1.1 9.5 3.4 189 10 189 165 1.3 0.1 1.6 1.1 11/29/2006 23:50:00 8.5 0.6 9.9 6.8 8.5 0.6 9.9 6.8 8.6 0.8 10.3 5.7 194 3 191 165 1.7 0.2 1.8 1.4 11/30/2006 00:00:00 8.3 0.6 9.9 6.8 8.3 0.6 10.3 6.8 8.5 0.6 10.3 6.5 193 4 194 165 2.1 0 2.3 1.8 11/30/2006 00:10:00 7.8 0.7 10.3 6.1 7.8 0.7 10.3 6.1 8.2 0.7 10.3 6.1 187 5 198 165 2.2 0 2.6 1.8 11/30/2006 00:20:00 8.1 1 11.8 5.7 8.1 1 11.5 5.3 8.5 1.1 12.2 6.1 194 9 171 165 2.5 0 2.8 2.3 11/30/2006 00:30:00 6.8 0.6 8 4.9 6.9 0.7 8 4.9 7 0.8 8.8 4.9 204 5 196 165 2.6 0 3 2.6 11/30/2006 00:40:00 5.7 0.8 7.2 3.8 5.8 0.8 7.6 3.8 5.9 0.9 8 3.8 205 7 215 165 2.5 0.1 2.8 2.3 11/30/2006 00:50:00 4.8 0.6 6.5 3 4.8 0.6 6.5 3.4 5.1 0.6 6.5 3 190 5 197 165 2.2 0.2 2.8 1.8 11/30/2006 01:00:00 4.4 0.6 6.1 3 4.4 0.6 6.1 3 4.6 0.5 5.7 3.4 191 6 194 165 1.9 0 2.3 1.8 11/30/2006 01:10:00 4.5 0.6 7.2 3.4 4.4 0.6 7.2 3.4 4.6 0.5 6.1 3.4 189 8 194 165 1.9 0 2.3 1.8 11/30/2006 01:20:00 4.6 0.7 8.4 3 4.5 0.6 7.6 3 4.7 0.6 7.6 3.4 168 11 150 165 1.9 0 2.1 1.8 11/30/2006 01:30:00 6.2 1.2 9.1 3 6 1.1 8.8 3 6.3 1.1 9.5 3.8 175 14 169 165 2.4 0.2 2.8 1.8 11/30/2006 01:40:00 6.3 1.7 10.7 3.8 6.2 1.6 10.3 3.8 6.3 1.7 10.3 3 188 11 191 165 2.7 0 3 2.6 11/30/2006 01:50:00 6 1 9.9 4.2 5.9 0.9 9.9 4.2 6.3 1 10.7 4.6 184 12 172 165 2.6 0.1 3 2.3 11/30/2006 02:00:00 4.9 1.1 8 3 4.8 1.1 7.6 2.6 5 1.1 8 3.4 179 11 193 165 2.4 0 2.8 2.1 11/30/2006 02:10:00 4.2 0.9 6.5 0.7 4.1 0.9 6.1 0.4 4.3 0.7 6.1 1.9 176 12 193 165 2 0.1 2.3 1.8 11/30/2006 02:20:00 5.2 0.8 6.8 3.8 5.1 0.7 6.5 3.4 5.4 0.9 7.2 3.4 184 7 189 165 2.1 0.2 2.6 1.8 11/30/2006 02:30:00 4.1 0.4 5.3 3 4 0.4 4.9 2.6 4.3 0.3 5.3 3.4 171 6 182 165 2.4 0 2.8 2.3 11/30/2006 02:40:00 3.7 0.3 4.2 2.6 3.5 0.3 4.2 2.6 3.8 0.4 4.6 2.6 166 8 165 165 2.3 0 2.6 2.1 11/30/2006 02:50:00 3.9 0.4 4.6 3 3.8 0.4 4.6 2.6 4 0.4 4.9 3 161 3 164 165 2.3 0 2.6 2.1 11/30/2006 03:00:00 4.9 0.9 7.2 3.4 4.9 0.9 6.8 3 5 0.8 7.6 3.8 154 5 156 165 2.3 0 2.6 2.3 11/30/2006 03:10:00 6.1 0.8 8 4.2 6 0.8 8 4.2 6.2 0.8 8.4 4.6 157 12 153 165 2.6 0 2.8 2.3 11/30/2006 03:20:00 6.7 0.6 8.4 4.9 6.5 0.6 8.4 4.9 6.8 0.6 8.4 4.6 154 6 153 165 2.7 0 2.8 2.6 11/30/2006 03:30:00 7.1 0.7 9.5 5.3 6.9 0.7 10.3 5.3 7.4 0.6 9.1 5.3 158 12 152 165 2.7 0 2.8 2.6 11/30/2006 03:40:00 6.1 0.8 8 3.8 5.9 0.8 7.6 3.8 6.3 0.7 7.6 4.6 161 9 158 165 2.6 0 2.8 2.6 11/30/2006 03:50:00 7.5 1 9.9 4.9 7.3 1 9.5 4.9 7.7 1 9.9 5.7 160 14 166 165 2.6 0 2.8 2.6 11/30/2006 04:00:00 8.8 1 10.7 6.1 8.6 1 10.3 6.1 8.7 1 11.1 6.5 162 11 165 165 2.6 0 2.8 2.6 11/30/2006 04:10:00 11.1 0.8 13.3 8.8 10.9 0.8 13 8.8 11.1 0.9 13 8.4 160 13 156 165 2.8 0 3 2.6 11/30/2006 04:20:00 12.2 1 14.5 9.5 11.9 0.8 14.5 9.1 12.2 0.9 14.5 9.1 160 17 7 165 2.7 0 2.8 2.6 11/30/2006 04:30:00 12.5 0.9 14.9 9.9 12.3 0.8 14.5 9.9 12.4 0.9 15.3 10.3 162 17 169 165 2.7 0 2.8 2.6 11/30/2006 04:40:00 13.3 0.7 14.5 10.7 13 0.6 14.5 10.7 13.2 0.8 14.5 10.7 163 17 162 165 2.7 0 2.8 2.6 11/30/2006 04:50:00 12.9 0.7 15.3 10.7 12.6 0.7 14.5 10.7 13 0.7 14.9 11.1 164 19 166 165 2.7 0 2.8 2.6 11/30/2006 05:00:00 13.7 1.1 16.4 11.1 13.4 1 16.1 10.7 13.9 1.1 16.4 11.1 169 12 175 165 2.7 0 3 2.6 11/30/2006 05:10:00 14.3 0.8 16.1 11.8 14 0.8 15.6 11.8 14.4 0.8 16.1 11.8 168 7 170 165 2.6 0 2.8 2.6 11/30/2006 05:20:00 14.2 0.8 16.4 12.2 13.9 0.8 16.1 11.8 14.2 0.8 16.8 12.2 166 9 169 165 2.6 0 2.8 2.6 11/30/2006 05:30:00 14.5 0.8 16.8 12.2 14.2 0.8 16.4 11.8 14.4 0.8 16.8 12.6 167 12 173 165 2.7 0 2.8 2.6 11/30/2006 05:40:00 13.4 1.1 16.1 11.1 13.1 1 16.1 10.7 13.2 1.1 16.4 10.7 161 12 166 165 2.7 0 3 2.6 11/30/2006 05:50:00 11.9 1 14.5 9.1 11.7 1 14.1 9.1 11.9 1.1 15.3 9.1 159 12 165 165 2.8 0 3 2.6 11/30/2006 06:00:00 12.5 1.2 15.6 9.5 12.3 1.2 15.3 9.5 12.3 1.3 16.1 9.1 163 17 169 165 2.8 0 3 2.6 11/30/2006 06:10:00 13 0.8 15.6 10.7 12.8 0.8 15.3 10.7 13.1 0.7 15.3 11.1 168 10 167 165 2.9 0 3 2.8 11/30/2006 06:20:00 10.3 1.2 13.7 8 10.1 1.2 13.3 8 10.3 1.3 13.3 8 162 12 165 165 2.8 0 3 2.6 11/30/2006 06:30:00 8.7 0.5 9.5 7.2 8.5 0.5 9.5 7.2 8.7 0.5 9.9 6.8 162 9 164 165 2.7 0 3 2.6 11/30/2006 06:40:00 7.2 0.8 9.1 5.7 7 0.8 8.8 5.3 7.3 0.8 8.8 5.7 162 10 157 165 2.8 0 3 2.8 11/30/2006 06:50:00 7.1 0.5 8.4 5.7 6.9 0.5 8.4 5.7 7.1 0.6 8.8 5.7 159 13 161 165 2.7 0 3 2.6 11/30/2006 07:00:00 7.8 0.6 9.5 5.7 7.7 0.6 9.5 5.3 7.9 0.6 9.5 6.1 153 5 151 165 2.8 0 3 2.6 11/30/2006 07:10:00 9 0.7 11.1 6.8 8.8 0.7 10.7 6.8 9 0.8 10.7 6.8 155 5 165 165 2.9 0 3.3 2.8 11/30/2006 07:20:00 10.3 1.3 13.7 7.2 10.1 1.3 13.7 7.6 10.2 1.2 13.7 8 161 17 166 165 3 0 3.3 2.8 11/30/2006 07:30:00 12 1.1 14.5 9.5 11.8 1.1 14.1 9.1 12 1 15.6 9.5 157 20 172 165 3.1 0 3.3 3 11/30/2006 07:40:00 12.2 1.1 14.9 9.1 12 1.1 14.5 8.8 12.1 1.1 14.9 9.1 162 15 178 165 3 0 3.3 2.8 11/30/2006 07:50:00 13.9 0.9 16.4 11.1 13.7 0.9 16.1 11.1 13.9 1 16.1 10.7 167 7 173 165 3.2 0 3.3 3 11/30/2006 08:00:00 14.5 1 16.8 11.8 14.1 0.9 16.1 11.8 14.6 1 16.8 11.5 170 5 171 165 3.2 0 3.3 3 11/30/2006 08:10:00 12.9 1 16.1 10.7 12.6 0.9 15.6 10.7 13 1 16.4 10.7 166 13 171 165 3.1 0 3.3 3 11/30/2006 08:20:00 10.5 0.8 13 8.8 10.3 0.8 12.6 8.8 10.4 0.9 13 8.8 162 7 172 165 3 0 3.3 2.8 11/30/2006 08:30:00 10 0.4 11.1 8.8 9.9 0.4 11.1 8.8 9.9 0.5 11.1 8.4 162 9 164 165 3 0 3.3 2.8 11/30/2006 08:40:00 8.9 0.8 10.7 6.8 8.8 0.8 10.7 6.5 8.9 0.7 10.7 6.8 158 10 164 165 3 0 3.3 2.8 11/30/2006 08:50:00 11.4 1.1 13.3 8.8 11.2 1.1 13.3 8 11.3 1.2 13.7 8.8 162 13 173 165 3 0 3.3 2.8 11/30/2006 09:00:00 14.1 0.6 15.3 12.2 13.8 0.6 14.9 11.8 14.1 0.7 15.6 11.8 166 12 168 165 3.1 0 3.3 2.8 11/30/2006 09:10:00 12.4 1.1 15.3 10.3 12 1.1 14.5 9.9 12.6 1.1 15.3 10.3 169 7 175 165 3.3 0 3.5 3.3 11/30/2006 09:20:00 9.8 0.7 11.1 8 9.4 0.7 10.7 7.6 9.8 0.8 11.5 8 172 5 173 165 3.4 0 3.5 3.3 11/30/2006 09:30:00 8.1 0.5 9.1 6.8 7.8 0.4 8.8 6.8 8.2 0.4 9.1 7.2 171 4 170 165 3.5 0 3.5 3.3 11/30/2006 09:40:00 6.6 0.7 8 5.3 6.5 0.7 7.6 5.3 6.8 0.8 8.4 5.3 161 4 168 165 3.5 0 3.8 3.3 11/30/2006 09:50:00 6.6 0.4 8 5.7 6.5 0.4 8 5.7 6.7 0.4 8 6.1 153 3 155 165 3.4 0 3.5 3.3 11/30/2006 10:00:00 6.7 0.5 8 4.9 6.6 0.4 8 4.6 6.9 0.4 7.6 5.3 151 4 153 165 3.5 0 3.8 3.5 11/30/2006 10:10:00 7.5 0.6 8.8 6.1 7.4 0.5 8.8 6.1 7.6 0.5 8.8 6.5 152 4 146 165 3.6 0 3.8 3.5 11/30/2006 10:20:00 8.3 0.6 9.9 6.8 8.1 0.6 9.5 6.5 8.4 0.5 9.9 6.5 153 8 157 165 3.8 0 4 3.5 11/30/2006 10:30:00 8.7 0.8 10.7 7.2 8.5 0.8 10.7 6.8 8.8 0.9 11.1 6.8 152 9 154 165 3.8 0 4 3.8 11/30/2006 10:40:00 8.2 0.8 10.3 6.5 8.1 0.8 9.9 6.5 8.2 0.7 10.3 6.5 152 6 157 165 3.9 0 4 3.8 11/30/2006 10:50:00 8.5 0.9 10.3 6.5 8.4 0.9 10.3 6.5 8.6 1 11.1 6.5 150 6 157 165 4 0 4.3 3.8 11/30/2006 11:00:00 9.5 0.6 11.5 8 9.5 0.6 11.1 7.6 9.5 0.6 11.1 7.6 150 4 151 165 3.9 0 4.3 3.8 11/30/2006 11:10:00 9.4 0.5 10.7 7.6 9.4 0.5 10.7 8 9.1 0.6 10.3 7.2 148 3 152 165 4 0 4.3 3.8 11/30/2006 11:20:00 9.1 0.5 10.3 7.6 9.1 0.5 10.3 8 8.9 0.5 10.3 7.2 147 3 146 165 4 0 4.3 3.8 11/30/2006 11:30:00 8.8 0.7 9.9 6.8 8.8 0.8 10.3 6.8 8.6 0.6 10.3 6.8 151 3 154 165 4 0 4.3 3.8 11/30/2006 11:40:00 7.8 0.6 8.8 6.5 7.7 0.6 8.8 6.1 7.8 0.6 9.1 6.1 155 4 153 165 4 0 4.3 3.8 11/30/2006 11:50:00 6.2 0.6 7.6 4.9 6 0.6 7.2 4.9 6.3 0.6 7.6 4.9 159 4 159 165 4 0 4.3 3.8 11/30/2006 12:00:00 6 0.6 8 4.6 5.8 0.6 8 4.6 5.9 0.5 8 4.9 166 11 185 165 4 0 4.3 3.8 11/30/2006 12:10:00 8.5 1.2 11.8 5.3 8.2 1.1 11.5 5.7 8.3 1.2 11.5 5.7 168 17 173 165 4.4 0 4.8 4 11/30/2006 12:20:00 10 0.9 12.2 8 9.8 0.8 11.8 8 10.1 0.8 11.8 8 166 9 170 165 4.5 0 4.8 4.3 11/30/2006 12:30:00 10.6 1 13 8 10.4 0.9 12.6 7.6 10.7 0.9 13 8 162 19 166 165 4.5 0 4.8 4.3 11/30/2006 12:40:00 9.5 1 12.2 6.5 9.3 1 11.8 6.1 9.6 1 12.6 6.5 156 12 161 165 4.5 0 4.8 4.3 11/30/2006 12:50:00 7.3 0.9 10.7 4.9 7.2 0.9 10.7 4.9 7.4 0.8 9.9 5.3 159 12 150 165 4.5 0 4.8 4.3 11/30/2006 13:00:00 7.2 0.8 9.1 4.9 7 0.7 8.8 4.9 7.3 0.7 9.1 5.3 162 12 156 165 4.4 0 4.5 4.3 11/30/2006 13:10:00 7.9 0.7 9.5 6.1 7.7 0.6 9.1 6.1 7.8 0.6 9.1 6.1 166 8 156 165 4.4 0 4.5 4.3 11/30/2006 13:20:00 7.5 0.7 8.8 5.7 7.2 0.7 8.8 5.7 7.4 0.6 8.8 5.7 168 5 165 165 4.3 0 4.5 4.3 11/30/2006 13:30:00 5.3 0.6 6.8 3.8 5.1 0.6 6.5 3 5.4 0.7 6.8 3.8 162 12 178 165 4.4 0 4.5 4.3 11/30/2006 13:40:00 4.4 0.6 6.1 2.6 4.3 0.5 5.7 2.6 4.6 0.5 5.7 3 160 7 169 165 4.4 0 4.8 4.3 11/30/2006 13:50:00 3.6 0.9 5.3 0.4 3.4 0.8 4.9 0.4 3.9 0.7 5.7 2.3 166 8 156 165 4.4 0 4.5 4.3 11/30/2006 14:00:00 2.5 0.7 4.6 0.7 2.4 0.6 4.2 0.4 2.7 0.5 4.2 1.5 174 9 176 165 4.4 0 4.8 4.3 11/30/2006 14:10:00 2.7 0.7 4.6 1.5 2.6 0.6 4.6 1.1 2.9 0.6 4.6 1.9 175 7 158 165 4.4 0 4.8 4.3 11/30/2006 14:20:00 1.3 0.6 2.3 0.4 1.2 0.6 2.3 0.4 1.7 0.5 3 0.7 180 4 184 165 4.5 0 4.8 4.3 11/30/2006 14:30:00 0.4 0.1 1.1 0.4 0.4 0 0.4 0.4 0.7 0.2 1.1 0.4 178 1 179 165 4.6 0 5 4.5 11/30/2006 14:40:00 0.6 0.3 1.5 0.4 0.5 0.3 1.5 0.4 0.9 0.4 1.9 0.4 184 9 178 165 4.6 0 4.8 4.5 11/30/2006 14:50:00 0.8 0.4 1.5 0.4 0.7 0.4 1.5 0.4 1.2 0.4 1.9 0.4 200 6 196 165 4.6 0 4.8 4.5 11/30/2006 15:00:00 0.7 0.3 1.1 0.4 0.6 0.3 1.1 0.4 1.4 0.2 1.9 0.7 202 3 204 165 4.6 0 5 4.5 11/30/2006 15:10:00 1.3 0.4 2.3 0.4 1.4 0.4 2.3 0.4 1.8 0.4 2.6 0.7 218 3 221 165 4.6 0 5 4.5 11/30/2006 15:20:00 1.9 0.3 2.3 1.1 2.2 0.2 2.6 1.5 2.5 0.2 3 1.9 234 11 223 165 4.4 0 4.8 4.3 11/30/2006 15:30:00 3 0.7 4.2 0.7 3.2 0.5 4.2 1.9 2.9 0.4 3.8 1.9 297 12 304 165 4.3 0 4.5 4.3 11/30/2006 15:40:00 5.8 1.2 8.4 3.8 5.8 1.2 8.4 3.8 4.9 1.5 8.4 2.6 295 5 285 165 4.3 0 4.5 4.3 11/30/2006 15:50:00 9.7 1.6 13.7 6.5 9.7 1.6 14.1 6.8 8.2 1.8 13 4.6 306 5 307 165 4 0 4.5 3.5 11/30/2006 16:00:00 13.4 1.1 15.6 9.9 13.5 1.2 16.4 9.9 11.4 1.4 14.5 7.6 306 5 296 165 3.3 0.2 3.8 2.8 11/30/2006 16:10:00 13.1 1.5 16.4 9.1 13.2 1.6 16.4 9.1 10.6 1.3 14.5 7.2 303 6 295 165 2.6 0.2 3 2.3 11/30/2006 16:20:00 15.8 1.5 19.1 12.2 15.9 1.5 19.1 11.8 12.6 1.8 17.2 8.4 303 5 304 165 2.3 0 2.6 2.1 11/30/2006 16:30:00 17.4 1 19.9 14.9 17.4 1 20.2 14.5 15.4 1.7 19.1 11.1 307 5 307 165 2.1 0 2.3 1.8 11/30/2006 16:40:00 16.3 1.3 19.9 13.3 16.3 1.3 19.9 13.3 15 1.5 18.7 10.7 309 5 301 165 1.9 0 2.3 1.8 11/30/2006 16:50:00 16.3 1.2 19.5 12.6 16.3 1.3 19.5 12.6 14.3 2.2 18.7 8 308 5 298 165 1.8 0 1.8 1.6 11/30/2006 17:00:00 15.6 1.2 18.3 11.8 15.7 1.3 18.3 11.5 11.9 1.5 16.1 9.1 301 6 303 165 1.8 0 1.8 1.6 11/30/2006 17:10:00 17.5 1.2 20.2 14.1 17.6 1.2 20.2 14.9 12.5 1.6 17.9 9.1 299 4 300 165 1.7 0 1.8 1.6 11/30/2006 17:20:00 17 1.7 20.2 12.2 16.9 1.8 20.6 11.8 13.7 2.6 19.9 8 305 5 313 165 1.6 0 1.8 1.4 11/30/2006 17:30:00 17.7 1.7 22.1 13.7 17.7 1.7 21.8 12.6 14.6 2.1 19.1 9.5 306 5 305 165 1.5 0 1.6 1.4 11/30/2006 17:40:00 16.8 1.7 21 12.6 16.8 1.8 21.4 12.6 13.3 1.9 18.7 9.1 299 7 295 165 1.4 0 1.6 1.4 11/30/2006 17:50:00 19.4 2.2 25.6 13.7 19.4 2.3 25.6 13.7 16.2 2.7 24 9.5 305 6 303 165 1.4 0 1.6 1.4 11/30/2006 18:00:00 21.3 2.1 25.6 16.1 21.3 2.2 25.6 15.6 18.6 2.1 23.3 13 306 5 302 165 1.4 0 1.6 1.4 11/30/2006 18:10:00 20.3 2 24.8 13.7 20.2 2.1 24.4 13.7 17.4 2.5 23.7 11.5 306 5 310 165 1.4 0 1.8 1.4 11/30/2006 18:20:00 20.6 1.7 24.4 13.3 20.6 1.7 24.4 13.7 16.3 2 22.9 11.8 303 6 302 165 1.5 0 1.8 1.4 11/30/2006 18:30:00 20.2 1.7 24 16.1 20.2 1.7 24 15.6 16.1 1.9 21.8 12.2 304 5 302 165 1.4 0 1.6 1.4 11/30/2006 18:40:00 20.2 1.7 23.7 14.9 20.3 1.7 23.7 14.9 15.5 1.9 21 9.9 302 5 298 165 1.4 0 1.6 1.4 11/30/2006 18:50:00 19 1.8 22.9 14.1 19 1.9 23.3 13.3 14.6 1.8 19.9 9.9 303 6 296 165 1.4 0 1.8 1.4 11/30/2006 19:00:00 18.5 1.9 22.9 13.7 18.5 1.9 22.6 13.3 14.3 1.9 20.6 9.9 303 6 298 165 1.4 0 1.6 1.4 11/30/2006 19:10:00 18.6 1.5 21.8 15.3 18.6 1.5 21.8 14.9 14.2 1.5 19.1 10.7 303 5 298 165 1.3 0 1.6 1.1 11/30/2006 19:20:00 17.9 1.3 21.4 13.3 17.9 1.3 21.4 13.7 14.3 1.9 20.6 9.9 305 5 307 165 1.3 0 1.4 1.1 11/30/2006 19:30:00 16.4 1.4 20.6 11.5 16.3 1.5 20.2 11.8 14.1 1.7 18.7 9.5 309 6 308 165 1.2 0 1.6 1.1 11/30/2006 19:40:00 16.3 1.7 20.2 11.8 16.1 1.7 19.9 11.5 15.1 1.7 19.1 10.7 313 5 318 165 1.2 0 1.6 1.1 11/30/2006 19:50:00 16.1 1.8 20.2 11.8 16 1.8 20.6 11.5 13.9 2.1 19.1 8.8 309 6 308 165 1.2 0 1.8 0.9 11/30/2006 20:00:00 16.4 1.2 20.2 13 16.3 1.2 19.9 12.2 14.8 1.7 18.7 10.7 311 6 316 165 1 0 1.6 0.9 11/30/2006 20:10:00 16.2 1.3 19.1 11.8 16 1.4 19.5 11.5 14.6 1.7 19.5 9.5 312 6 301 165 0.9 0 1.4 0.9 11/30/2006 20:20:00 16 1.4 19.5 13.3 15.8 1.4 19.5 12.6 14.8 1.7 19.1 11.1 313 6 310 165 0.8 0 1.4 0.9 11/30/2006 20:30:00 17.4 1.5 21 12.6 17.3 1.5 21 12.6 15.9 1.9 20.2 11.5 312 5 311 165 0.8 0 1.4 0.7 11/30/2006 20:40:00 18.1 1.3 21.8 13.7 18 1.3 21.8 13.3 17.1 1.8 21.8 11.1 314 7 308 165 0.8 0 1.1 0.7 11/30/2006 20:50:00 16.7 1.3 20.2 13 16.6 1.4 20.2 12.6 15 1.7 19.5 10.7 312 6 310 165 0.8 0 1.4 0.7 11/30/2006 21:00:00 17.9 1.3 20.6 13.3 17.9 1.3 20.6 13.3 14 1.8 19.1 10.3 305 6 305 165 0.7 0 1.1 0.7 11/30/2006 21:10:00 18.5 1.3 21 14.1 18.5 1.3 21.4 14.1 15.2 1.7 20.2 11.1 307 4 305 165 0.5 0 0.9 0.4 11/30/2006 21:20:00 17.4 1.2 20.2 14.1 17.3 1.2 20.2 13.7 14.1 1.6 18.7 10.7 308 5 305 165 0.5 0 0.9 0.2 11/30/2006 21:30:00 16.4 1.1 18.7 13 16.4 1.1 18.7 13 13 1.5 16.8 9.5 306 5 302 165 0.4 0 0.9 0.2 11/30/2006 21:40:00 15.6 1.6 19.9 11.1 15.5 1.7 20.2 10.7 12.7 1.6 17.9 8.4 307 7 305 165 0.4 0 0.9 0.2 11/30/2006 21:50:00 15.1 1.5 20.2 10.3 15 1.6 20.6 9.9 11.9 1.7 17.9 8 305 8 308 165 0.4 0 0.9 0.2 11/30/2006 22:00:00 15.6 1.4 20.2 11.8 15.6 1.4 20.2 11.5 12.3 1.7 18.3 8.8 305 6 304 165 0.4 0 0.9 0.2 11/30/2006 22:10:00 16.5 2.1 23.3 10.7 16.3 2.1 22.9 10.3 13.4 2.3 19.9 7.2 307 7 312 165 0.6 0.1 0.9 0.2 11/30/2006 22:20:00 15.1 1.8 21.4 9.5 15 1.8 22.1 9.5 11.9 1.7 18.3 8 303 6 307 165 0.8 0 1.4 0.7 11/30/2006 22:30:00 13.7 2.4 19.5 6.8 13.5 2.4 19.9 6.5 12.1 2 17.2 7.2 314 17 307 165 0.8 0 1.1 0.7 11/30/2006 22:40:00 13.2 1.9 19.9 8.8 13 1.8 19.5 8.4 11.3 1.5 17.2 8 308 11 296 165 0.7 0 1.4 0.7 11/30/2006 22:50:00 12 1.7 17.6 8.4 11.8 1.7 17.2 8.4 10.4 1.8 15.3 6.5 312 11 310 165 0.5 0 0.9 0.2 11/30/2006 23:00:00 12.1 1.6 16.4 6.8 12 1.6 16.4 6.8 10.5 1.6 14.9 6.1 309 10 297 165 0.4 0.1 0.9 0.2 11/30/2006 23:10:00 13.4 1.4 17.6 9.1 13.3 1.4 17.2 9.5 10.6 1.3 16.1 7.6 305 6 293 165 0.2 0.1 0.7 -0.1 11/30/2006 23:20:00 13.3 1.3 16.8 9.1 13.1 1.3 16.1 9.1 10.7 1.2 14.1 7.6 306 6 301 165 -0.2 0.1 0.4 -0.3 11/30/2006 23:30:00 13.5 1.5 16.8 9.1 13.3 1.5 16.4 9.1 11.9 1.7 16.1 6.5 309 7 305 165 -0.1 0 -0.1 -0.3 11/30/2006 23:40:00 14.3 1.4 17.9 11.1 14.1 1.4 17.6 10.7 12.8 1.7 17.2 8.4 312 5 314 165 -0.2 0 0.2 -0.3 11/30/2006 23:50:00 15.7 1.1 19.9 12.6 15.4 1.1 19.1 12.6 15.3 1.5 19.1 10.3 316 5 321 165 -0.1 0 0.2 -0.3 12/01/2006 00:00:00 15.5 1.4 19.1 11.8 15.3 1.5 18.7 11.5 14 1.7 19.5 9.5 312 7 320 165 -0.2 0.1 0.2 -0.5 12/01/2006 00:10:00 16.6 1.7 20.6 13 16.4 1.7 20.6 12.2 16 2 21 11.1 318 6 316 165 -0.3 0 -0.1 -0.5 12/01/2006 00:20:00 18.5 1.7 22.9 14.9 18.3 1.7 22.6 14.1 17.9 1.6 21.8 13 317 6 313 165 -0.3 0 0.2 -0.5 12/01/2006 00:30:00 18.6 1.5 21.4 13.7 18.4 1.5 21.8 13.7 18.3 1.8 21.8 13.3 321 7 284 165 -0.3 0 0.2 -0.5 12/01/2006 00:40:00 18.9 1 21.4 14.9 18.7 1 21.4 14.9 18.9 1.1 21.4 15.6 319 5 319 165 -0.4 0 -0.1 -0.5 12/01/2006 00:50:00 19.1 1 21.8 15.6 18.9 1 21.8 15.3 19 1.2 21.8 15.3 319 5 319 165 -0.3 0 -0.1 -0.5 12/01/2006 01:00:00 18.2 1.2 20.6 13.7 18 1.2 20.6 13.3 17.9 1.2 21 14.1 317 4 317 165 -0.4 0 -0.1 -0.5 12/01/2006 01:10:00 16 1.3 19.1 13 15.9 1.2 19.1 12.6 15.4 1.8 19.1 10.3 314 6 322 165 -0.6 0 -0.1 -0.8 12/01/2006 01:20:00 17.3 1.5 21 13.3 17.1 1.5 20.6 13 17.1 1.6 20.6 12.6 317 5 316 165 -0.6 0 -0.3 -0.8 12/01/2006 01:30:00 16.2 1.4 21 12.6 16.1 1.5 21 12.6 15.1 1.7 20.6 10.7 313 6 323 165 -0.6 0 -0.1 -0.8 12/01/2006 01:40:00 16.9 1.2 19.1 13.7 16.7 1.2 19.1 13.3 16.2 1.2 19.5 12.6 315 5 317 165 -0.6 0 -0.3 -0.8 12/01/2006 01:50:00 16.4 1 19.5 14.1 16.2 1.1 19.5 13.7 15.7 1.5 19.5 10.7 314 5 315 165 -0.6 0 -0.3 -0.8 12/01/2006 02:00:00 15.5 0.9 18.3 12.6 15.4 1 17.9 12.2 14.5 1.4 18.3 9.5 314 6 314 165 -0.8 0 -0.3 -0.8 12/01/2006 02:10:00 14.8 1.1 17.2 11.1 14.7 1.1 17.2 11.1 14.8 1.2 17.6 10.7 318 5 319 165 -0.8 0 -0.5 -0.8 12/01/2006 02:20:00 13.3 1.3 16.8 9.9 13.1 1.3 16.8 9.9 13.2 1.5 16.8 9.5 321 6 307 165 -0.8 0.1 -0.3 -1 12/01/2006 02:30:00 12.7 1.1 15.6 10.3 12.5 1.1 15.6 9.9 12.4 1.1 14.9 9.5 318 5 316 165 -0.9 0 -0.5 -1.2 12/01/2006 02:40:00 12.7 1.2 16.1 9.5 12.5 1.2 16.4 9.5 12 1.4 15.6 8 317 7 311 165 -0.9 0 -0.5 -1.2 12/01/2006 02:50:00 12.8 1.5 16.4 9.1 12.6 1.5 16.4 9.1 12.5 1.7 18.3 8.4 318 7 316 165 -0.8 0 -0.5 -1 12/01/2006 03:00:00 13.1 1.6 18.3 9.5 12.9 1.6 17.9 9.5 12.5 1.7 17.6 8 318 10 314 165 -0.6 0 -0.3 -0.8 12/01/2006 03:10:00 12.8 1.5 17.2 8.8 12.7 1.5 17.2 8.8 12.2 1.7 17.6 7.6 316 8 312 165 -0.8 0 -0.3 -1 12/01/2006 03:20:00 12.6 1.7 16.8 8 12.5 1.7 16.8 8 12.2 1.7 17.2 7.2 319 8 302 165 -0.9 0 -0.3 -1 12/01/2006 03:30:00 14.5 1.3 17.2 9.5 14.3 1.3 17.2 10.7 14 1.5 17.6 9.9 319 7 315 165 -0.9 0 -0.5 -1.2 12/01/2006 03:40:00 13.1 1.3 17.2 9.1 12.9 1.3 16.8 8.8 12.4 1.4 16.8 8.4 317 10 319 165 -1 0 -0.5 -1.2 12/01/2006 03:50:00 13.5 1.4 18.7 10.3 13.4 1.4 17.9 9.9 12.6 1.3 15.6 9.5 316 8 314 165 -1.1 0 -0.8 -1.2 12/01/2006 04:00:00 15.1 1.4 18.7 11.5 14.9 1.5 19.1 11.5 14.4 1.6 17.9 9.5 317 8 310 165 -1.2 0.1 -0.8 -1.4 12/01/2006 04:10:00 14.3 1.4 18.3 10.7 14.1 1.3 17.9 10.7 13.5 1.3 16.8 9.9 316 8 310 165 -1.6 0 -1.2 -1.9 12/01/2006 04:20:00 12.6 1.5 17.2 9.1 12.4 1.5 17.2 9.5 11.7 1.7 16.4 7.6 320 10 325 165 -1.7 0 -1.4 -1.9 12/01/2006 04:30:00 12.7 1.5 16.1 9.5 12.5 1.5 16.1 9.5 11.9 1.5 16.8 7.2 317 8 319 165 -1.7 0 -1.4 -1.9 12/01/2006 04:40:00 12.4 1.5 18.3 9.1 12.3 1.4 17.6 9.1 11.4 1.5 15.6 7.6 314 8 292 165 -1.8 0 -1.4 -2.1 12/01/2006 04:50:00 14.1 1.5 18.3 9.5 13.9 1.5 17.9 9.5 12.8 1.6 16.4 8.4 313 9 297 165 -1.8 0 -1.4 -1.9 12/01/2006 05:00:00 13.4 1.7 17.9 8.4 13.3 1.7 17.9 8.8 12.5 1.7 17.9 8.4 316 11 317 165 -1.7 0 -1.4 -1.9 12/01/2006 05:10:00 10.3 1.3 15.3 5.7 10.3 1.3 14.9 5.7 9.3 1.6 14.9 4.6 313 13 324 165 -1.8 0.1 -1.4 -2.1 12/01/2006 05:20:00 10.3 1.5 16.1 6.8 10.3 1.5 15.6 6.8 9.3 1.5 13.3 4.9 310 12 294 165 -1.6 0 -1.2 -1.9 12/01/2006 05:30:00 8.3 1.5 13 4.9 8.2 1.5 12.6 4.9 7.6 1.2 12.6 4.9 315 13 304 165 -1.7 0 -1.2 -1.9 12/01/2006 05:40:00 9 1.6 13.7 5.7 8.9 1.6 13.3 5.7 8.4 1.7 13.7 4.6 318 11 312 165 -1.8 0.1 -1.4 -2.1 12/01/2006 05:50:00 7.7 1.7 11.8 3.8 7.6 1.7 11.8 4.2 7.4 1.7 11.5 3.8 329 11 314 165 -2.1 0 -1.4 -2.4 12/01/2006 06:00:00 8.5 1.4 11.8 5.7 8.4 1.3 11.8 5.7 7.7 1.2 10.7 4.9 316 12 310 165 -1.9 0 -1.7 -2.1 12/01/2006 06:10:00 8 1.3 11.1 4.2 7.9 1.2 10.7 4.2 7.3 1.2 10.7 4.2 320 15 327 165 -1.9 0 -1.7 -2.1 12/01/2006 06:20:00 8.2 1.6 13.3 4.9 8.2 1.5 12.6 4.6 7.1 1.3 13 3.4 310 12 316 165 -2 0 -1.4 -2.1 12/01/2006 06:30:00 9.6 1.6 15.6 4.9 9.6 1.6 16.1 4.9 8.5 1.5 13.7 4.6 315 13 291 165 -1.8 0.1 -1.4 -1.9 12/01/2006 06:40:00 10.3 1.3 13.3 6.5 10.1 1.3 13 6.5 9.8 1.5 13 5.7 323 11 330 165 -1.8 0 -1.7 -1.9 12/01/2006 06:50:00 8.9 1.4 13 3.8 8.8 1.5 13.7 4.2 8.5 1.3 12.6 5.3 328 13 343 165 -2 0 -1.4 -2.1 12/01/2006 07:00:00 11.5 1.7 15.6 7.6 11.3 1.7 15.3 7.6 10.5 1.6 16.1 6.5 314 10 299 165 -2.1 0 -1.9 -2.4 12/01/2006 07:10:00 10.3 1.3 14.1 6.5 10.2 1.3 14.1 6.5 9.9 1.2 13 6.1 323 10 315 165 -2.4 0.1 -1.7 -2.6 12/01/2006 07:20:00 12.6 2.3 18.7 8 12.5 2.4 18.7 8 11.8 2.2 19.1 7.2 320 12 310 165 -2.4 0.1 -2.1 -2.8 12/01/2006 07:30:00 11.5 1.7 16.8 7.6 11.4 1.7 16.4 7.2 11 1.8 16.1 6.8 326 12 342 165 -2.5 0 -2.1 -2.6 12/01/2006 07:40:00 11.4 1.7 15.3 6.8 11.3 1.7 14.9 6.5 10.4 1.5 14.5 5.7 319 15 302 165 -2.5 0 -2.1 -2.6 12/01/2006 07:50:00 14.2 1.8 17.9 9.5 14.1 1.8 17.9 9.5 12.4 1.7 16.8 8.4 310 7 299 165 -2.4 0 -2.1 -2.6 12/01/2006 08:00:00 15.4 1.1 17.9 12.6 15.2 1.2 17.9 12.2 13.8 1.4 17.6 9.5 311 7 306 165 -2.5 0 -2.1 -2.6 12/01/2006 08:10:00 14.1 1.5 19.5 10.7 13.9 1.5 19.1 10.3 12.9 1.5 17.2 9.1 312 7 304 165 -2.5 0 -2.1 -2.8 12/01/2006 08:20:00 14.7 1.7 19.1 9.1 14.6 1.7 18.3 9.5 12.5 1.8 17.6 8 308 8 313 165 -2.5 0 -2.1 -2.6 12/01/2006 08:30:00 13.6 1.7 18.3 9.5 13.4 1.7 17.9 9.5 11.2 1.6 17.6 7.6 306 8 297 165 -2.5 0 -2.1 -2.8 12/01/2006 08:40:00 13.7 1.7 18.3 9.1 13.5 1.7 18.7 9.1 11.8 1.7 16.1 7.2 309 8 304 165 -2.5 0 -2.1 -2.6 12/01/2006 08:50:00 13.9 1.7 17.2 9.5 13.7 1.6 17.2 9.1 11.5 1.5 15.3 7.2 306 7 299 165 -2.5 0 -2.1 -2.6 12/01/2006 09:00:00 13 1.4 16.8 8.8 12.9 1.3 16.4 8.8 10.3 1.3 13.7 6.8 303 7 297 165 -2.5 0 -1.9 -2.6 12/01/2006 09:10:00 12.6 1.3 16.4 9.5 12.5 1.3 16.4 9.1 10.4 1.5 14.1 7.2 305 8 310 165 -2.4 0 -2.1 -2.6 12/01/2006 09:20:00 12.6 1.3 15.6 9.5 12.5 1.2 15.6 9.5 10.6 1.6 14.9 7.2 309 7 308 165 -2.4 0 -2.1 -2.6 12/01/2006 09:30:00 10.9 1.2 14.1 8.8 10.9 1.1 13.7 8.8 8.1 1.1 11.8 5.7 300 5 305 165 -2.4 0.1 -2.1 -2.8 12/01/2006 09:40:00 10.3 1 13 8.4 10.3 1 13 8.4 7.8 1 11.5 5.7 297 5 293 165 -2.6 0 -2.6 -2.8 12/01/2006 09:50:00 10.7 1.1 13 7.2 10.7 1.1 13.3 6.8 9 1.5 12.2 5.7 293 6 292 165 -2.4 0.1 -1.9 -2.8 12/01/2006 10:00:00 11.3 1.1 15.3 8.8 11.2 1 14.5 8.8 8.9 1.2 12.2 6.1 300 8 302 165 -2.1 0 -1.4 -2.1 12/01/2006 10:10:00 10.5 2 15.6 4.6 10.5 2 15.3 4.6 8.5 1.3 12.2 4.6 307 13 303 165 -1.8 0 -1.4 -2.1 12/01/2006 10:20:00 7.9 1.4 11.5 4.9 7.8 1.4 11.5 4.9 7.1 1.3 10.7 3.8 332 15 354 165 -1.3 0.1 -1 -1.7 12/01/2006 10:30:00 6.8 1.3 10.7 3.8 6.7 1.3 10.3 3.4 5.7 1.3 9.9 3 327 13 316 165 -0.9 0.2 -0.5 -1.2 12/01/2006 10:40:00 6.2 1.5 10.3 2.6 6.2 1.3 9.9 3 5.4 1.3 9.5 1.9 321 17 312 165 -0.8 0 -0.5 -1.2 12/01/2006 10:50:00 9.3 1.7 13 5.7 9.1 1.7 12.6 5.3 8.2 1.5 12.2 4.9 317 12 332 165 -1.2 0.1 -0.5 -1.4 12/01/2006 11:00:00 9.5 1.7 14.1 5.7 9.4 1.7 14.5 5.7 9.3 1.7 14.5 5.3 325 11 344 165 -1.2 0.2 -0.8 -1.7 12/01/2006 11:10:00 9.6 1.4 13.3 6.1 9.5 1.3 13.3 6.5 9.2 1.4 13.7 6.1 322 11 346 165 -1.3 0.1 -1.2 -1.9 12/01/2006 11:20:00 9.1 1.3 12.2 4.2 9 1.3 11.8 4.9 8.3 1.3 11.8 4.2 314 10 325 165 -1.4 0 -0.8 -1.7 12/01/2006 11:30:00 9.1 1.4 13.7 5.7 9 1.3 14.1 5.7 8 1.5 12.2 4.6 313 12 326 165 -1.4 0.1 -1.2 -1.9 12/01/2006 11:40:00 9.4 1.1 11.5 5.3 9.3 1.2 11.8 5.7 8.4 1.5 11.5 4.2 317 15 346 165 -0.8 0.1 -0.3 -1.2 12/01/2006 11:50:00 9.1 2 14.1 3 9 1.9 13.7 3.4 7.5 1.8 12.6 2.6 307 10 304 165 -0.3 0.1 -0.1 -0.8 12/01/2006 12:00:00 9.8 1.6 14.5 5.7 9.7 1.6 14.1 5.7 8.5 1.6 12.2 4.9 313 12 318 165 -0.4 0 -0.1 -0.8 12/01/2006 12:10:00 8.5 1.3 11.8 5.3 8.4 1.3 11.8 5.3 6.9 1 9.9 4.6 303 11 296 165 -0.4 0 -0.1 -0.5 12/01/2006 12:20:00 9.8 1 13 6.5 9.7 1 12.6 6.8 8 1 14.1 5.3 307 8 316 165 -0.5 0.1 -0.1 -1 12/01/2006 12:30:00 11.7 1.3 14.9 8 11.6 1.3 14.9 8 9.6 1.4 13.3 6.1 307 7 310 165 -0.7 0 -0.5 -1.4 12/01/2006 12:40:00 12.3 1.5 16.1 8.8 12.2 1.4 16.1 8.8 9.9 1.5 14.1 6.5 306 8 293 165 -0.8 0.1 -0.3 -1.2 12/01/2006 12:50:00 11.3 1.1 15.3 8.4 11.2 1.1 14.5 8.4 9.9 1.3 13.3 6.8 311 8 296 165 -1 0 -0.5 -1.2 12/01/2006 13:00:00 10.2 1.4 14.1 6.8 10.1 1.4 14.1 6.8 8.8 1.5 14.1 4.9 309 9 313 165 -0.8 0 -0.5 -0.8 12/01/2006 13:10:00 12.4 1.7 17.9 8 12.2 1.7 18.3 7.2 10.7 1.5 14.9 7.2 309 9 299 165 -0.9 0.1 -0.5 -1 12/01/2006 13:20:00 12.9 1.7 16.8 7.6 12.7 1.7 16.8 8.4 11.5 1.7 16.1 7.6 316 12 300 165 -0.2 0.3 0.4 -0.8 12/01/2006 13:30:00 11.9 1.8 19.5 6.8 11.8 1.8 19.5 6.5 10 1.7 16.1 5.7 313 10 348 165 0.5 0 0.9 0.2 12/01/2006 13:40:00 9.9 2.9 17.9 0.4 9.8 2.9 18.7 0.7 8.3 2.6 16.4 1.5 316 30 301 165 0.8 0.2 1.4 0.2 12/01/2006 13:50:00 8.9 2.2 14.5 1.9 8.9 2.1 14.9 1.1 6.6 2 12.6 1.9 304 27 323 165 1.1 0 1.6 0.7 12/01/2006 14:00:00 10.2 2.3 16.8 4.9 10.1 2.3 16.8 4.6 9 2.2 14.1 3.4 316 16 300 165 0.8 0 1.4 0.2 12/01/2006 14:10:00 10.9 2.1 17.9 6.8 10.7 2.1 17.6 6.1 9.1 2.4 17.6 2.6 309 12 322 165 0.4 0.2 0.9 0.2 12/01/2006 14:20:00 14.1 2.2 21 9.5 13.9 2.1 20.6 9.5 13 2.2 20.2 8 315 9 317 165 0 0.2 0.7 -0.5 12/01/2006 14:30:00 15 2 21 10.3 14.8 2.1 22.6 10.3 13.1 2.2 19.9 8.4 312 9 303 165 -0.2 0.2 0.2 -0.8 12/01/2006 14:40:00 14.6 2.1 19.9 9.1 14.5 2.1 19.9 9.5 13.2 2.2 19.1 6.8 320 12 329 165 0 0 0.2 -0.5 12/01/2006 14:50:00 15.1 1.8 20.2 8.4 14.9 1.7 20.2 8.8 13 2.1 19.1 8 314 13 316 165 0.1 0 0.2 -0.3 12/01/2006 15:00:00 15.6 2.5 21 8.4 15.4 2.4 20.6 8.8 14.4 2.5 20.2 8.4 317 12 322 165 -0.1 0 0.4 -0.5 12/01/2006 15:10:00 14 2 20.2 5.3 13.7 2 21 7.2 12.8 2.2 17.6 6.5 320 17 312 165 -0.1 0 0.4 -0.5 12/01/2006 15:20:00 14.5 2.3 22.1 9.1 14.4 2.3 22.6 9.1 13.6 2.6 23.3 8.8 322 13 346 165 -0.3 0.1 0.2 -0.8 12/01/2006 15:30:00 14.2 1.9 20.6 9.5 14 1.9 21 10.3 13.1 2.1 20.2 7.2 318 10 310 165 -0.2 0 0.2 -0.5 12/01/2006 15:40:00 14.3 1.9 19.5 9.1 13.7 2.1 19.1 8.4 13.4 1.8 18.3 8.8 330 15 354 165 -0.2 0 -0.1 -0.5 12/01/2006 15:50:00 15 1.7 19.5 11.5 14.9 1.7 19.1 9.9 14.1 1.7 19.1 8.8 323 13 319 165 -0.1 0 0.2 -0.3 12/01/2006 16:00:00 13.4 1.4 17.9 9.9 13.3 1.4 17.6 9.5 12.8 1.6 17.6 8.4 329 14 330 165 -0.2 0 0.2 -0.3 12/01/2006 16:10:00 11.3 1.8 16.1 6.5 11.1 1.7 15.6 6.5 10.5 1.9 15.3 5.7 322 11 317 165 -0.4 0 -0.1 -0.8 12/01/2006 16:20:00 12.8 2.4 19.5 7.6 12.5 2.4 18.3 6.5 12.7 2.6 19.5 6.5 334 12 355 165 -0.5 0.1 -0.1 -0.8 12/01/2006 16:30:00 14.2 2 21.4 9.5 13.9 2.2 19.9 7.2 14 2.1 19.5 9.1 341 10 358 165 -0.3 0 -0.1 -0.5 12/01/2006 16:40:00 14.8 1.8 21 9.9 14.3 2 19.9 8 14.7 2.1 19.9 7.6 337 14 3 165 -0.3 0 -0.1 -0.5 12/01/2006 16:50:00 13.5 2.4 23.3 8.4 13.4 2.5 23.7 8.4 13.3 2.3 21.4 8.4 331 13 317 165 -0.3 0 0.2 -0.5 12/01/2006 17:00:00 11.6 2.3 17.6 6.8 11.4 2.4 17.6 3.8 11.5 2.2 17.6 7.6 334 12 316 165 -0.3 0 0.2 -0.5 12/01/2006 17:10:00 13.7 2.4 20.6 8.4 13.6 2.4 20.2 8 13.4 2.3 20.6 8.8 330 14 347 165 -0.2 0 0.2 -0.3 12/01/2006 17:20:00 16.1 3.3 22.9 7.6 15.8 3.6 22.9 5.3 15.9 3.3 22.9 8.4 336 14 319 165 -0.2 0 -0.1 -0.3 12/01/2006 17:30:00 16.7 2.6 23.7 9.5 16.3 3.2 23.7 7.6 16.6 2.7 23.3 9.5 339 12 333 165 -0.3 0 0.2 -0.5 12/01/2006 17:40:00 16.4 2.5 21.4 9.5 16.1 2.9 21.4 7.2 16.3 2.6 24 8 337 11 338 165 -0.3 0 -0.1 -0.5 12/01/2006 17:50:00 16.3 2.9 25.2 10.3 16 3.1 24.4 7.2 15.7 3.2 24.4 9.5 337 11 332 165 -0.4 0 -0.1 -0.5 12/01/2006 18:00:00 17.3 3.5 26 8 16.9 3.6 26 7.6 16.8 3.6 25.2 6.5 338 10 340 165 -0.5 0 -0.1 -0.8 12/01/2006 18:10:00 15 3.2 23.7 6.5 14.7 3.3 23.3 6.1 14.7 3.2 22.1 5.3 332 15 330 165 -0.4 0 -0.1 -0.5 12/01/2006 18:20:00 11.5 2.6 21.8 6.1 11.3 2.6 21.8 6.1 11 2.7 22.1 5.3 326 17 313 165 -0.4 0 -0.1 -0.8 12/01/2006 18:30:00 14.5 2.7 21 6.8 14.3 2.8 21.8 6.5 14 3.1 22.6 5.3 333 12 339 165 -0.4 0 -0.1 -0.5 12/01/2006 18:40:00 16.9 2.9 24 10.7 16.7 2.8 24 10.3 16.6 3.1 24.8 10.7 333 11 341 165 -0.4 0 -0.3 -0.5 12/01/2006 18:50:00 14.6 2.5 22.9 7.6 14.5 2.5 22.6 6.8 14.2 2.6 22.6 8.4 329 12 315 165 -0.5 0 -0.1 -0.8 12/01/2006 19:00:00 15.7 2.9 25.6 9.9 15.3 3.3 25.6 6.8 15.2 3.1 24.8 9.5 334 13 326 165 -0.5 0 -0.1 -0.8 12/01/2006 19:10:00 14.5 2.2 20.2 8.8 14.3 2.2 19.5 7.6 14.1 2.3 19.9 8.4 334 11 334 165 -0.6 0 -0.1 -0.8 12/01/2006 19:20:00 14.1 2.8 21.4 8.4 13.4 3.1 21 7.2 13.1 2.9 21.8 6.8 340 17 321 165 -0.7 0 -0.3 -0.8 12/01/2006 19:30:00 12.7 1.8 17.6 7.2 12.2 2 17.9 6.8 11.5 2 17.2 5.3 340 15 354 165 -0.8 0 -0.5 -1 12/01/2006 19:40:00 12.1 2 16.4 6.1 11.9 2 16.8 5.3 10.6 1.8 15.3 4.9 336 11 346 165 -0.8 0.1 -0.3 -1 12/01/2006 19:50:00 10 2.5 16.1 3.4 9.8 2.6 16.4 2.6 8.5 2.5 14.9 2.6 332 14 316 165 -0.8 0 -0.5 -0.8 12/01/2006 20:00:00 13.1 2 17.6 8 12.9 1.9 17.2 7.6 11.8 1.9 16.4 5.7 335 9 330 165 -0.9 0 -0.5 -1 12/01/2006 20:10:00 14.1 1.8 18.3 10.3 13.9 1.7 17.9 9.1 12.8 1.9 16.8 7.6 333 9 331 165 -0.8 0 -0.5 -1 12/01/2006 20:20:00 15.1 2.4 20.6 9.1 14.9 2.3 19.9 8.4 14.1 2.6 19.9 8 335 8 338 165 -0.8 0 -0.5 -1 12/01/2006 20:30:00 14.1 2 18.7 7.6 13.9 2 18.7 8 13.3 2.3 17.9 7.2 333 9 337 165 -0.8 0 -0.5 -0.8 12/01/2006 20:40:00 14.1 1.9 19.1 9.9 14 2.1 19.1 8 13.6 2 18.7 9.5 337 10 339 165 -0.8 0 -0.5 -0.8 12/01/2006 20:50:00 12.3 2.5 19.9 8 12.1 2.5 19.9 6.1 11.7 2.4 19.5 7.6 338 8 336 165 -0.8 0.1 -0.3 -1 12/01/2006 21:00:00 12.7 1.6 17.2 8.8 12.5 1.6 17.2 9.1 12.2 1.6 17.2 8 338 8 343 165 -0.9 0 -0.5 -1 12/01/2006 21:10:00 10.8 1.5 15.6 7.6 10.5 1.7 14.9 4.6 10.2 1.3 14.1 6.5 340 12 330 165 -0.9 0 -0.5 -1.2 12/01/2006 21:20:00 10.8 1.5 14.5 6.8 10.6 1.5 14.5 5.7 10.4 1.3 15.6 7.6 335 9 330 165 -0.9 0 -0.5 -1.2 12/01/2006 21:30:00 12.9 1.7 17.9 9.1 12.7 1.9 17.6 7.6 12.7 1.8 18.3 7.6 338 9 334 165 -0.9 0 -0.5 -1 12/01/2006 21:40:00 12.2 2.5 18.7 5.3 12 2.6 17.9 4.9 11.9 2.5 18.3 5.3 334 12 332 165 -0.8 0 -0.5 -0.8 12/01/2006 21:50:00 11.6 2 16.1 6.5 11.5 2 16.1 6.1 11.4 2.1 15.6 6.1 333 10 332 165 -0.8 0 -0.3 -0.8 12/01/2006 22:00:00 11.8 2.3 17.9 6.8 11.5 2.5 17.9 5.3 11.5 2.4 19.1 6.8 336 11 340 165 -0.7 0 -0.3 -0.8 12/01/2006 22:10:00 11.5 1.7 14.9 6.8 11.4 1.8 15.3 6.5 11.3 1.7 15.6 6.8 336 9 338 165 -0.7 0 -0.3 -0.8 12/01/2006 22:20:00 9.3 1.2 13 6.1 9.2 1.3 13.3 6.5 8.9 1.5 12.6 4.9 330 10 343 165 -0.8 0.1 -0.3 -0.8 12/01/2006 22:30:00 10.4 1.3 13.7 6.5 10.3 1.3 13.7 5.3 10.2 1.5 13.3 6.1 329 9 330 165 -0.8 0 -0.5 -1 12/01/2006 22:40:00 9.6 1.7 14.5 5.7 9.6 1.7 14.1 6.1 9.3 1.7 14.1 4.6 336 9 334 165 -0.9 0 -0.5 -1 12/01/2006 22:50:00 11.5 1.5 14.9 7.6 11.2 1.7 15.3 6.5 11.2 1.4 14.5 7.2 343 9 342 165 -0.8 0 -0.3 -1 12/01/2006 23:00:00 10.9 1.2 14.9 7.6 10.5 1.5 14.1 5.7 10.6 1.3 14.1 7.6 341 9 354 165 -0.8 0 -0.5 -1 12/01/2006 23:10:00 11.5 1.2 15.6 8.8 11.3 1.4 16.1 6.5 11.1 1.3 15.3 8 341 9 338 165 -0.8 0 -0.5 -1 12/01/2006 23:20:00 11.9 1.5 15.6 8.4 11.8 1.5 16.1 8 11.7 1.4 15.3 8.8 337 7 327 165 -0.6 0 -0.3 -0.8 12/01/2006 23:30:00 12.3 1.7 16.1 7.6 12.2 1.9 16.4 6.1 12.1 1.7 16.4 8 340 9 344 165 -0.5 0 -0.3 -0.8 12/01/2006 23:40:00 12.9 1.5 16.1 9.9 12.9 1.8 16.8 7.2 12.8 1.5 16.4 8.4 345 6 339 165 -0.3 0 -0.1 -0.5 12/01/2006 23:50:00 12.8 1 15.3 9.5 12.7 1.2 15.6 9.5 12.8 1 15.3 9.9 344 6 339 165 -0.5 0 -0.1 -0.8 12/02/2006 00:00:00 12.4 1.6 16.8 8.4 12.2 1.7 15.3 7.6 12.2 1.7 16.4 7.6 340 8 347 165 -0.4 0 -0.3 -0.5 12/02/2006 00:10:00 11.7 1.5 15.3 8.4 11.7 1.6 15.6 8 11.6 1.5 15.6 7.6 340 8 350 165 -0.2 0 -0.1 -0.5 12/02/2006 00:20:00 11.4 1.5 14.5 7.2 11.3 1.5 15.3 7.2 11.1 1.5 15.3 6.5 340 9 344 165 0.1 0 0.4 -0.1 12/02/2006 00:30:00 10 1.5 13.7 7.2 9.7 1.5 13.7 5.3 9.6 1.5 13.7 6.5 340 10 352 165 0.2 0 0.7 -0.1 12/02/2006 00:40:00 10.6 1.5 14.5 6.5 10.5 1.5 14.5 6.5 10.5 1.6 15.3 7.2 342 8 359 165 0.3 0 0.7 0.2 12/02/2006 00:50:00 11.5 1.5 14.9 6.8 11.4 1.4 14.5 6.8 11.5 1.5 15.3 7.6 334 7 336 165 0.4 0 0.9 0.2 12/02/2006 01:00:00 11.1 1.7 14.9 7.2 11 1.7 14.5 5.7 10.8 1.7 14.1 6.8 336 8 338 165 0.4 0 0.9 0.2 12/02/2006 01:10:00 9.5 1.5 13 4.6 9.3 1.7 13 3.8 9.4 1.7 13.7 5.3 337 11 338 165 0.3 0.1 0.9 0.2 12/02/2006 01:20:00 10 1.2 12.2 5.7 10 1.2 12.2 5.7 10 1.3 12.6 5.7 335 7 341 165 0.2 0 0.4 0.2 12/02/2006 01:30:00 10.7 1.5 13.3 6.8 10.6 1.5 13.7 6.8 10.6 1.5 14.5 6.5 334 7 346 165 0.2 0 0.7 0.2 12/02/2006 01:40:00 12.1 1.6 16.1 7.2 12 1.6 16.4 7.2 11.6 1.8 15.6 5.7 335 9 343 165 0.3 0 0.7 0.2 12/02/2006 01:50:00 12.4 1.4 16.1 9.1 12.3 1.6 15.6 7.6 12 1.7 15.6 6.1 338 10 320 165 0.5 0 0.9 0.4 12/02/2006 02:00:00 12.4 1.5 17.2 8.4 11.8 1.7 16.4 7.2 12.2 1.6 17.2 8 346 8 353 165 0.5 0.1 0.9 0.2 12/02/2006 02:10:00 11.2 1.5 15.3 8.4 10.9 1.7 16.1 6.8 11.2 1.5 15.3 8 343 10 346 165 0.4 0.1 0.9 0.2 12/02/2006 02:20:00 10.5 1.3 15.6 7.2 10 1.5 14.1 6.1 10.5 1.3 16.4 7.6 344 10 1 165 0.2 0 0.7 0.2 12/02/2006 02:30:00 11.6 2.1 17.9 4.6 11.5 2.1 17.6 3.8 11.5 2 16.8 7.2 334 11 339 165 0.4 0 0.7 0.2 12/02/2006 02:40:00 11.6 1.7 16.4 6.5 11.6 1.7 16.4 6.5 11 1.8 16.8 6.5 331 11 329 165 0 0 0.7 -0.3 12/02/2006 02:50:00 11.2 2 17.6 6.8 11 2.1 17.6 6.1 10.8 1.9 17.2 5.7 339 11 332 165 -0.2 0 0.2 -0.3 12/02/2006 03:00:00 12.7 2.3 17.2 6.5 12.7 2.2 17.6 6.8 12.2 2.1 16.4 6.8 335 8 337 165 -0.1 0 0.2 -0.3 12/02/2006 03:10:00 11.5 1.8 17.2 8 11 1.9 17.2 6.5 10.7 1.7 15.6 7.2 343 9 336 165 0.2 0.1 0.7 -0.1 12/02/2006 03:20:00 11.2 1.4 14.9 6.5 10.3 1.7 16.1 6.1 10.5 1.6 14.5 5.7 350 7 347 165 0.3 0 0.7 0.2 12/02/2006 03:30:00 9.2 1.7 13.7 4.9 7.4 1.8 12.2 3 8.6 1.7 14.1 4.2 2 12 12 165 0.7 0.1 1.4 0.2 12/02/2006 03:40:00 8.1 2.1 15.3 4.2 7.6 1.7 13.3 4.6 7.8 2 14.1 4.6 33 21 11 165 1.1 0.1 1.4 0.9 12/02/2006 03:50:00 4.8 1 6.8 2.6 4.8 1 6.8 2.6 4.8 0.9 6.8 2.6 43 9 41 165 0.8 0 1.1 0.9 12/02/2006 04:00:00 5 1.2 9.1 2.3 5 1.2 9.1 1.9 4.9 1.1 9.1 2.6 48 9 62 165 1 0 1.1 0.9 12/02/2006 04:10:00 5.5 1 7.6 3 5.5 1 7.6 2.6 5.1 1 7.6 3 49 8 39 165 1 0 1.4 0.9 12/02/2006 04:20:00 6.9 1 8.8 3.8 6.9 1 8.8 3.8 6.6 1.1 8.8 4.2 42 8 37 165 1.1 0 1.4 0.9 12/02/2006 04:30:00 6.2 0.9 8.8 3.8 6.2 0.9 8.8 3.8 6 1 8.4 4.2 41 8 34 165 1.2 0 1.4 0.9 12/02/2006 04:40:00 6.2 1.1 8.4 3.8 6.2 1.1 8.8 3.8 5.8 1.2 8.8 3 63 12 48 165 1.1 0 1.4 0.9 12/02/2006 04:50:00 6.8 1.2 9.5 4.2 6.9 1.2 9.1 3.8 6.5 1.1 9.1 3.4 57 10 63 165 0.8 0.1 1.4 0.9 12/02/2006 05:00:00 5.8 1.2 9.5 3 5.8 1.3 9.5 3 5.6 1.2 9.1 3 46 10 48 165 0.8 0 0.9 0.7 12/02/2006 05:10:00 6.8 1.1 9.9 4.6 6.8 1.1 9.9 4.6 6.5 1 9.5 4.2 52 10 58 165 0.8 0 0.9 0.7 12/02/2006 05:20:00 6.8 1.4 9.9 3.4 6.8 1.4 9.9 3 6.5 1.3 9.9 3.4 55 11 45 165 0.5 0 0.9 0.2 12/02/2006 05:30:00 5.3 0.6 6.8 3.8 5.3 0.7 6.8 3.4 5.1 0.6 6.8 3.4 40 9 34 165 0.3 0 0.7 0.2 12/02/2006 05:40:00 6.6 0.8 8.8 4.6 6.7 0.8 9.1 4.6 6.2 0.7 8.8 4.2 43 6 37 165 0.5 0.1 0.9 0.2 12/02/2006 05:50:00 8.9 2.4 14.9 4.9 8.9 2.5 14.9 4.9 8.3 2.3 14.1 4.6 57 16 48 165 0.8 0.1 1.4 0.2 12/02/2006 06:00:00 8.9 1 11.5 6.5 9.1 1.1 11.5 6.5 8.6 1.1 11.1 6.1 84 6 88 165 0.1 0 0.7 -0.1 12/02/2006 06:10:00 7.4 1.1 9.9 4.2 7.5 1.2 10.3 4.2 7 1.1 9.9 4.6 72 9 79 165 0.2 0 0.7 0.2 12/02/2006 06:20:00 6.4 1 9.5 4.6 6.5 1 9.5 4.6 6.2 1 8.8 4.2 73 10 84 165 0.5 0 0.9 0.2 12/02/2006 06:30:00 8.4 1.2 11.5 5.7 8.6 1.2 11.5 6.1 8.1 1.1 10.7 5.3 80 7 82 165 0.9 0 1.1 0.7 12/02/2006 06:40:00 8.5 1.3 12.6 6.1 8.6 1.3 12.6 6.1 8.2 1.1 11.5 5.3 85 8 90 165 1 0 1.4 0.9 12/02/2006 06:50:00 9.5 1.7 13.7 5.3 9.7 1.7 14.5 5.7 9 1.6 13 5.3 85 8 93 165 1.1 0 1.4 0.9 12/02/2006 07:00:00 9.7 1.3 12.2 6.1 9.9 1.3 13 6.5 9.1 1.3 12.2 5.7 92 7 74 165 1 0 1.4 0.9 12/02/2006 07:10:00 9.1 1.3 12.6 6.5 9.3 1.3 12.6 6.1 8.8 1.3 12.2 5.3 92 8 98 165 0.9 0 1.1 0.9 12/02/2006 07:20:00 8 1.2 11.5 5.7 8.2 1.2 11.8 5.7 7.6 1.1 10.3 4.9 96 12 103 165 0.8 0 0.9 0.7 12/02/2006 07:30:00 9.8 1.4 13 5.7 10 1.4 13.3 6.1 9.3 1.3 13.3 6.1 119 6 112 165 0.8 0 0.9 0.7 12/02/2006 07:40:00 7.8 0.9 10.3 5.3 7.9 0.9 10.3 5.7 7.5 1 9.9 4.9 113 7 102 165 0.8 0 1.1 0.9 12/02/2006 07:50:00 6.8 0.8 8.8 3.8 7 0.9 9.1 3.8 6.5 0.9 8.8 4.2 107 6 108 165 0.9 0 1.1 0.9 12/02/2006 08:00:00 5.5 0.7 6.8 3.8 5.6 0.7 7.2 3.8 5.2 0.8 6.8 3.4 96 11 81 165 0.8 0 1.4 0.9 12/02/2006 08:10:00 6.7 0.7 8.8 4.9 6.8 0.7 8.8 5.3 6.5 0.7 8.4 4.2 78 5 79 165 0.9 0 1.4 0.9 12/02/2006 08:20:00 7.2 0.5 8.8 5.7 7.4 0.5 8.8 6.1 6.9 0.5 8.4 5.3 80 5 84 165 1 0 1.4 0.9 12/02/2006 08:30:00 7.4 0.8 9.5 5.3 7.6 0.8 9.9 5.3 7.1 0.8 8.8 4.6 85 6 94 165 1.2 0 1.4 0.9 12/02/2006 08:40:00 7.1 1 9.9 4.6 7.2 1.1 9.9 4.6 6.8 1.1 9.5 4.2 73 9 87 165 1.2 0 1.4 0.9 12/02/2006 08:50:00 7.3 1.2 11.1 4.9 7.5 1.3 11.8 4.6 7 1.2 10.3 4.6 70 8 77 165 1.2 0 1.4 1.1 12/02/2006 09:00:00 7.6 1.1 9.9 4.9 7.7 1.1 10.3 4.6 7.3 1 9.9 4.9 64 8 56 165 1.4 0 1.6 1.4 12/02/2006 09:10:00 7.3 1.4 10.3 4.2 7.4 1.5 10.7 4.2 7 1.3 10.3 4.2 60 8 65 165 1.4 0 1.6 1.4 12/02/2006 09:20:00 7.7 1 9.9 4.9 7.8 1 10.3 4.6 7.3 1 9.9 4.6 56 8 54 165 1.5 0 1.8 1.4 12/02/2006 09:30:00 7.3 1 9.9 4.6 7.4 1.1 9.9 4.6 7.1 1 9.1 4.6 56 7 60 165 1.7 0 1.8 1.6 12/02/2006 09:40:00 7 0.9 8.8 4.6 7.1 1 9.1 4.9 6.7 0.9 8.8 4.2 62 9 58 165 1.8 0 1.8 1.6 12/02/2006 09:50:00 7.4 1.2 11.5 4.6 7.5 1.3 11.8 4.9 7 1 10.7 4.6 56 9 46 165 1.9 0 2.1 1.8 12/02/2006 10:00:00 9.1 1.3 11.8 5.7 9.2 1.4 12.2 5.3 8.8 1.3 11.8 4.9 52 10 59 165 2 0 2.3 1.8 12/02/2006 10:10:00 9.4 1.3 12.6 6.1 9.4 1.3 12.6 6.1 9 1.3 12.6 5.7 51 8 50 165 2.1 0 2.3 1.8 12/02/2006 10:20:00 8.5 1.5 13.3 4.9 8.5 1.6 13.3 4.9 8.2 1.6 12.6 4.9 49 9 44 165 2.1 0 2.3 1.8 12/02/2006 10:30:00 7.8 1.1 11.5 5.3 7.8 1.2 11.5 4.9 7.5 1.2 10.7 4.6 50 10 55 165 2.2 0 2.3 2.1 12/02/2006 10:40:00 7.1 1.1 9.9 3.8 7.1 1.1 9.9 3.8 6.8 1.1 9.5 4.2 57 9 62 165 2.3 0 2.6 2.3 12/02/2006 10:50:00 7.6 1.3 10.7 4.2 7.6 1.4 10.7 4.2 7.3 1.3 10.3 4.6 54 9 57 165 2.4 0 2.8 2.3 12/02/2006 11:00:00 7.5 1.2 11.1 4.6 7.5 1.3 11.1 4.6 7.2 1.2 10.7 4.2 49 9 50 165 2.6 0 2.8 2.6 12/02/2006 11:10:00 8.2 1.2 11.8 5.7 8.3 1.2 12.2 5.7 7.7 1.2 11.1 4.9 47 9 46 165 2.7 0 2.8 2.6 12/02/2006 11:20:00 7.4 1.4 9.9 4.2 7.4 1.4 10.3 3.8 7.3 1.2 10.7 4.9 47 9 55 165 2.7 0 3 2.6 12/02/2006 11:30:00 8 1.4 11.1 4.6 8 1.4 11.1 4.9 7.6 1.2 11.5 4.9 50 9 53 165 2.9 0 3 2.8 12/02/2006 11:40:00 8.5 1.3 11.8 3.8 8.6 1.5 11.8 3.4 8.1 1.5 11.5 4.6 54 9 56 165 2.9 0 3.3 2.8 12/02/2006 11:50:00 8.1 1.3 11.5 4.9 8.2 1.3 11.5 4.9 7.8 1.3 11.8 5.3 57 11 60 165 3 0 3.3 2.8 12/02/2006 12:00:00 8.3 1.5 11.8 4.9 8.4 1.5 12.2 4.9 7.9 1.4 10.7 4.2 64 12 65 165 3 0 3.3 3 12/02/2006 12:10:00 8.8 1.7 13.7 6.1 8.9 1.7 14.1 5.7 8.5 1.7 13.7 5.3 68 10 59 165 3 0 3.3 2.8 12/02/2006 12:20:00 9.3 1.7 14.5 5.7 9.4 1.8 15.3 5.3 9 1.5 13.3 6.1 68 9 52 165 3.2 0 3.5 3 12/02/2006 12:30:00 9.4 1.3 12.2 6.1 9.5 1.3 12.6 6.1 9 1.3 11.8 5.7 62 9 56 165 3.1 0 3.3 3 12/02/2006 12:40:00 9.2 1.7 13.7 5.3 9.4 1.8 13.7 5.3 9 1.7 14.1 4.9 75 9 86 165 3 0 3.3 2.8 12/02/2006 12:50:00 10.1 1.6 14.1 6.5 10.4 1.7 14.5 6.5 9.8 1.5 14.1 6.5 81 8 82 165 3.2 0 3.5 3 12/02/2006 13:00:00 9 1.2 12.2 6.5 9.2 1.2 12.6 6.5 8.8 1.1 12.6 6.1 74 8 73 165 3.2 0 3.5 3 12/02/2006 13:10:00 9.6 2.2 14.5 5.3 9.8 2.2 15.3 5.3 9.3 2.1 14.9 5.7 76 11 75 165 3.1 0 3.3 2.8 12/02/2006 13:20:00 10.3 1.6 15.3 6.5 10.5 1.6 14.5 6.8 9.8 1.6 13.7 6.5 79 8 77 165 3 0 3.3 3 12/02/2006 13:30:00 8.9 1.5 13 5.3 9 1.6 12.6 5.7 8.5 1.5 12.6 5.3 68 9 60 165 3 0 3.3 2.8 12/02/2006 13:40:00 8.6 1.4 11.8 4.9 8.8 1.5 12.2 5.3 8.5 1.4 12.6 5.3 68 9 78 165 3 0 3.3 2.8 12/02/2006 13:50:00 9.9 1.5 13.7 5.7 10.1 1.6 14.1 6.1 9.7 1.5 13.3 6.5 72 8 80 165 3.1 0 3.3 3 12/02/2006 14:00:00 9.7 1.6 14.9 6.1 9.9 1.6 15.6 6.5 9.4 1.7 15.3 6.5 72 9 68 165 3.2 0 3.3 3 12/02/2006 14:10:00 10.5 1.5 14.5 7.2 10.7 1.6 14.9 7.2 10.1 1.5 13.7 6.8 71 9 68 165 3.2 0 3.3 3 12/02/2006 14:20:00 10.3 1.6 15.3 6.8 10.4 1.7 15.6 6.8 9.9 1.6 14.9 6.5 68 9 64 165 3.2 0 3.3 3 12/02/2006 14:30:00 10.3 1.7 16.1 6.5 10.5 1.7 16.1 6.1 9.9 1.6 14.5 6.5 73 9 70 165 3.2 0 3.5 3 12/02/2006 14:40:00 9.9 1.8 14.5 6.1 9.9 1.9 14.9 5.7 9.6 1.7 14.5 6.5 67 9 78 165 3.2 0 3.5 3.3 12/02/2006 14:50:00 11.1 1.5 16.1 7.6 11.3 1.6 16.4 7.6 10.9 1.4 15.3 7.2 71 11 70 165 3.3 0 3.5 3.3 12/02/2006 15:00:00 9.9 1.6 15.6 6.1 10 1.7 16.1 6.1 9.6 1.4 13.3 6.5 70 10 74 165 3.2 0 3.5 3.3 12/02/2006 15:10:00 11.9 2.2 18.3 7.2 12.1 2.3 18.7 7.2 11.7 2.2 17.6 7.2 70 9 61 165 3.1 0 3.3 3 12/02/2006 15:20:00 11.7 1.9 17.2 7.6 11.9 2 17.6 7.6 11.3 1.8 16.8 7.2 73 9 68 165 3.1 0 3.3 3 12/02/2006 15:30:00 10.1 1.7 14.1 5.7 10.3 1.7 14.5 5.7 9.6 1.7 13.7 6.1 67 11 80 165 3 0 3.3 3 12/02/2006 15:40:00 9.7 1.8 15.3 5.7 9.7 1.9 15.3 5.7 9.1 1.7 14.5 4.9 65 13 68 165 3 0 3.3 2.8 12/02/2006 15:50:00 9.6 1.4 14.1 6.1 9.7 1.5 14.5 6.5 9.1 1.5 13.3 4.9 60 10 68 165 3 0 3.3 2.8 12/02/2006 16:00:00 9.1 1.7 13.7 4.9 9.1 1.7 13.7 4.9 8.9 1.7 13.7 4.9 57 11 63 165 3 0 3.3 2.8 12/02/2006 16:10:00 9.5 1.4 14.5 5.7 9.5 1.5 14.9 6.1 9 1.3 12.2 5.7 62 12 81 165 3 0 3.3 2.8 12/02/2006 16:20:00 10.4 1.6 14.1 6.5 10.4 1.7 14.5 6.1 10 1.6 14.5 5.7 55 9 58 165 3 0 3.3 2.8 12/02/2006 16:30:00 10.1 2.2 15.6 5.3 10.2 2.3 16.1 5.3 9.8 2 15.3 5.3 54 12 69 165 2.9 0 3.3 2.8 12/02/2006 16:40:00 10.7 2 15.3 5.3 10.8 2.1 14.9 5.3 10.3 2 15.3 5.3 65 11 58 165 2.8 0 3 2.6 12/02/2006 16:50:00 12 2.1 17.2 6.1 12 2.2 16.8 6.1 11.6 2 16.4 5.7 56 10 33 165 2.7 0.2 3 2.3 12/02/2006 17:00:00 12.3 1.8 17.2 8 12.3 1.9 17.9 7.6 12 1.8 17.6 7.6 47 9 52 165 2.4 0 2.6 2.3 12/02/2006 17:10:00 11.1 2 16.4 6.1 11.1 2 16.8 6.1 10.6 1.9 16.8 6.5 43 11 56 165 2.5 0 2.8 2.3 12/02/2006 17:20:00 12 2.1 17.9 6.8 11.9 2.1 17.9 6.5 11.4 1.8 16.4 7.2 40 9 42 165 2.4 0 2.8 2.3 12/02/2006 17:30:00 12.2 1.9 16.8 5.7 12.1 2 16.8 6.1 11.9 2 17.6 7.2 40 9 39 165 2.4 0 2.6 2.3 12/02/2006 17:40:00 12 1.8 16.8 7.2 12 1.8 17.2 7.6 11.9 2 17.9 8 38 8 32 165 2.3 0 2.6 2.3 12/02/2006 17:50:00 13.4 2.2 18.7 8.4 13.4 2.2 18.7 8.4 13.1 2.2 17.9 7.2 40 8 36 165 2.3 0 2.6 2.1 12/02/2006 18:00:00 12.6 1.9 16.8 7.6 12.6 1.9 17.2 7.6 12.2 1.9 17.9 6.5 45 8 40 165 2.3 0 2.6 2.3 12/02/2006 18:10:00 10.4 2.2 14.9 5.3 10.5 2.3 15.6 5.3 10 2.1 14.5 5.7 47 10 50 165 2.3 0 2.6 2.3 12/02/2006 18:20:00 12 2.1 17.2 6.8 12.2 2.2 17.6 6.8 11.8 1.8 16.4 6.8 48 10 54 165 2.3 0 2.6 2.3 12/02/2006 18:30:00 10.6 1.9 15.3 6.1 10.5 2 15.6 6.5 10.4 1.9 15.6 6.1 39 10 50 165 2.4 0 2.6 2.3 12/02/2006 18:40:00 11.1 2.2 15.6 5.7 11.1 2.3 16.1 5.7 10.7 2.1 16.1 6.5 50 10 52 165 2.2 0 2.3 2.1 12/02/2006 18:50:00 12.2 1.8 16.4 7.2 12.2 1.9 16.8 7.2 11.6 1.8 16.4 6.1 43 9 46 165 2.1 0 2.3 1.8 12/02/2006 19:00:00 13.4 2.4 19.9 8 13.4 2.4 19.5 7.2 13 2.4 19.5 6.8 38 9 42 165 2.3 0 2.6 2.1 12/02/2006 19:10:00 13.6 1.8 17.9 8.8 13.6 1.9 18.3 9.1 13.2 1.9 17.9 8 39 9 37 165 2.1 0 2.6 1.8 12/02/2006 19:20:00 14.2 1.6 17.6 9.1 14.2 1.7 17.6 8.4 13.7 1.7 17.9 8.4 36 9 37 165 2.1 0 2.3 1.8 12/02/2006 19:30:00 13.4 1.7 17.6 8.8 13.4 1.8 17.6 8.8 13 1.9 17.9 6.8 31 10 35 165 2.1 0 2.3 1.8 12/02/2006 19:40:00 14.4 2 19.1 7.6 14.2 2.1 19.5 7.2 13.7 2.2 18.7 6.8 32 9 43 165 2.1 0 2.3 1.8 12/02/2006 19:50:00 13.8 1.8 18.7 9.1 13.6 1.9 17.9 8.4 13.4 1.9 17.6 7.6 30 9 29 165 2.1 0 2.3 1.8 12/02/2006 20:00:00 13.8 2 19.5 8.8 13.6 2.1 19.1 8.8 13.5 2 18.7 8.8 27 9 23 165 2.1 0 2.3 1.8 12/02/2006 20:10:00 15.5 2 19.9 9.1 15.3 2 19.5 9.1 14.9 2 19.9 9.1 31 10 34 165 2 0 2.3 1.8 12/02/2006 20:20:00 14.7 2.3 19.5 8.8 14.4 2.4 19.5 8.8 14.2 2.3 18.3 8.4 28 11 39 165 2.1 0 2.3 1.8 12/02/2006 20:30:00 15.4 2.2 19.5 9.9 15.1 2.4 19.9 8 14.8 2.4 19.9 8.8 27 10 18 165 1.8 0 2.1 1.6 12/02/2006 20:40:00 15.3 1.7 19.5 11.1 14.8 2 19.1 9.9 14.6 1.7 19.5 9.5 24 9 32 165 1.9 0 2.3 1.8 12/02/2006 20:50:00 15.3 2.2 19.9 8.4 15 2.3 19.9 8.4 14.7 2.3 20.2 9.9 27 9 32 165 2 0 2.3 1.8 12/02/2006 21:00:00 15.2 2.4 21 9.1 14.9 2.6 20.6 8.8 14.8 2.4 21 9.1 28 10 32 165 1.9 0 2.3 1.8 12/02/2006 21:10:00 16.6 1.9 21 11.1 16.2 2.2 21 10.7 16 2.2 20.6 11.1 26 10 31 165 1.9 0 2.1 1.8 12/02/2006 21:20:00 16.7 2.1 22.1 8.8 16.4 2.3 21.4 8 16.1 2.1 22.6 9.9 26 10 15 165 1.8 0 1.8 1.6 12/02/2006 21:30:00 17.5 2.3 21.8 10.3 17 2.5 21.4 9.9 16.7 2.5 22.1 9.9 23 10 16 165 1.7 0 1.8 1.6 12/02/2006 21:40:00 17.4 1.9 22.1 11.5 16.6 2.3 22.1 9.9 16.8 2.2 22.9 10.3 21 10 23 165 1.6 0 1.8 1.6 12/02/2006 21:50:00 16.8 2.4 23.3 11.5 16 2.6 22.1 9.9 16.5 2.3 22.1 10.7 23 9 19 165 1.6 0 1.8 1.4 12/02/2006 22:00:00 17.6 2 22.9 13 16.9 2.3 21.8 11.1 17 2.1 21.4 11.8 24 10 25 165 1.5 0 1.6 1.4 12/02/2006 22:10:00 17.4 2.7 22.9 11.5 16.5 2.9 22.1 8.4 17.2 2.7 22.1 9.9 23 9 29 165 1.6 0 1.8 1.6 12/02/2006 22:20:00 18.7 2.3 23.3 11.8 18.1 2.4 22.9 11.5 18.1 2.4 22.9 10.7 25 11 27 165 1.5 0 1.6 1.4 12/02/2006 22:30:00 19.8 1.9 22.9 14.1 19.2 2 22.9 13.7 18.7 2.2 24 13.7 27 10 32 165 1.4 0 1.6 1.4 12/02/2006 22:40:00 18.7 2 22.1 11.8 17.8 2.2 21.8 11.1 18 2.2 22.6 11.8 23 7 23 165 1.4 0 1.6 1.4 12/02/2006 22:50:00 17 2.5 22.1 11.1 15.7 2.8 21.4 9.1 16.2 2.6 21 11.1 21 8 26 165 1.4 0 1.6 1.4 12/02/2006 23:00:00 17.2 1.9 20.6 11.8 16.1 2.1 20.2 9.1 17.1 1.8 21.4 12.2 22 8 28 165 1.4 0 1.6 1.4 12/02/2006 23:10:00 15.9 1.7 19.9 12.2 14.4 2 19.1 8.8 16.4 1.9 20.2 12.2 21 9 32 165 1.4 0 1.6 1.4 12/02/2006 23:20:00 15.6 2.1 20.6 10.7 13.9 2.5 19.5 8 16.2 2.2 21 11.1 22 4 24 165 1.4 0 1.6 1.4 12/02/2006 23:30:00 17.8 2.4 22.9 11.8 16.6 2.7 22.6 9.9 17.3 2.4 23.7 12.2 22 8 26 165 1.5 0 1.8 1.4 12/02/2006 23:40:00 17.7 2.2 22.1 12.6 16.1 2.7 21.4 9.9 17.1 2.1 22.1 11.5 19 7 32 165 1.7 0 1.8 1.6 12/02/2006 23:50:00 17.1 1.9 21.4 11.8 15.7 2.5 21 8 16.5 1.9 21.4 11.8 19 9 20 165 1.9 0.1 2.3 1.6 12/03/2006 00:00:00 17.9 2.4 23.3 11.5 16.5 2.8 22.6 10.7 17.4 2.4 22.9 9.9 19 8 24 165 1.9 0 2.3 1.8 12/03/2006 00:10:00 18.2 2.2 23.7 12.2 17.5 2.5 22.9 11.1 17.6 2.3 24 12.6 21 9 27 165 2.1 0.1 2.6 1.8 12/03/2006 00:20:00 17.6 2.3 22.9 11.8 16.8 2.6 22.9 9.9 17 2.3 22.9 11.8 21 9 29 165 2.4 0 2.6 2.3 12/03/2006 00:30:00 16.5 2 21.8 11.5 15.3 2.4 21.4 9.9 16 1.9 22.1 10.7 17 10 25 165 2.5 0 2.8 2.3 12/03/2006 00:40:00 17.8 1.8 22.1 13 16.7 2.2 21.4 9.9 17.1 2 22.6 12.2 17 9 3 165 2.7 0 2.8 2.6 12/03/2006 00:50:00 15.9 2.4 22.1 9.9 15.2 2.7 21.4 8.4 15.1 2.5 21.8 9.5 20 10 20 165 3 0 3.3 2.8 12/03/2006 01:00:00 16.5 2.2 21.8 11.5 15.4 2.5 21.8 9.1 15.9 2.3 21 10.3 17 9 26 165 2.9 0 3.3 2.6 12/03/2006 01:10:00 18.1 2.3 23.7 11.5 17.2 2.8 23.3 9.5 17.2 2.5 23.7 11.5 19 8 22 165 2.7 0 3 2.6 12/03/2006 01:20:00 17.7 2.4 23.3 11.5 17.2 2.6 22.9 10.3 16.9 2.4 22.9 10.7 21 9 20 165 2.8 0 3 2.6 12/03/2006 01:30:00 18.3 2.6 22.9 11.8 17.6 2.8 22.9 9.1 17.7 2.5 23.3 11.1 20 8 18 165 2.5 0.1 3 2.3 12/03/2006 01:40:00 17 2.3 21.8 11.1 16.1 2.6 21.8 9.9 16.5 2.3 21.8 10.7 19 9 23 165 2.4 0 2.8 2.3 12/03/2006 01:50:00 17.6 2 22.9 13 16.7 2.5 22.6 10.3 16.9 2.2 22.6 11.1 18 9 26 165 2.3 0 2.6 2.3 12/03/2006 02:00:00 18.3 2.3 23.3 12.2 17.8 2.5 23.7 11.8 17.9 2.4 23.7 11.5 22 8 21 165 2.4 0 2.8 2.3 12/03/2006 02:10:00 18.5 2.6 24.8 11.5 17.1 3.2 24.4 8.8 18.4 2.5 23.7 12.2 18 10 26 165 2.1 0 2.6 1.8 12/03/2006 02:20:00 16.8 2.7 22.9 10.3 15.8 2.8 22.6 9.9 16.3 2.8 22.1 9.5 18 8 10 165 2.3 0 2.6 1.8 12/03/2006 02:30:00 17.2 1.9 21.8 11.8 14.9 2.6 21.8 9.5 16.9 1.9 21.8 12.2 12 9 6 165 2 0 2.3 1.8 12/03/2006 02:40:00 18.3 2.6 23.7 11.8 17 3.1 23.7 9.1 17.9 2.6 24.4 11.5 16 8 11 165 2 0 2.3 1.8 12/03/2006 02:50:00 16.6 1.8 21.4 12.2 14.5 2.9 21 8.8 16.3 1.8 21.4 11.8 13 8 25 165 2.1 0 2.3 1.8 12/03/2006 03:00:00 17 1.7 22.1 13 14.8 2.3 21.4 9.9 16.6 1.7 21.4 13 12 9 19 165 2.2 0 2.3 2.1 12/03/2006 03:10:00 16.7 1.9 21.4 11.8 13.7 2.6 19.9 8.4 16.6 2 21 11.5 9 8 19 165 2.3 0 2.3 2.1 12/03/2006 03:20:00 15.8 1.8 21 11.8 12.4 2.3 19.9 7.2 15.6 1.8 21.8 11.1 7 8 10 165 2.4 0 2.6 2.1 12/03/2006 03:30:00 15.9 2.1 21.8 11.5 12.5 2.2 17.6 6.8 15.8 2 21.8 11.5 8 8 19 165 2.6 0 2.8 2.3 12/03/2006 03:40:00 16.8 1.7 21.4 11.8 13.8 2.6 20.6 8.4 16.6 2 22.1 11.5 9 7 17 165 2.8 0 3 2.6 12/03/2006 03:50:00 15.1 1.5 19.1 10.7 11.9 1.7 17.9 6.8 14.7 1.5 19.9 11.1 8 7 11 165 2.9 0 3.3 2.8 12/03/2006 04:00:00 16 1.7 22.1 11.5 12.7 2 19.5 8.8 15.8 1.7 21 11.8 9 7 358 165 3.1 0 3.3 3 12/03/2006 04:10:00 13.8 1.5 17.9 9.5 10.9 1.9 17.9 6.1 13.7 1.5 17.9 9.9 7 9 23 165 3.2 0 3.3 3 12/03/2006 04:20:00 14.5 1.5 18.3 9.5 11.5 1.9 17.6 7.6 14.1 1.5 17.9 10.3 9 7 7 165 3.4 0 3.5 3.3 12/03/2006 04:30:00 13.7 1.9 19.1 9.5 10.9 2.1 16.4 7.2 13.4 1.7 17.9 9.1 9 8 10 165 3.5 0 3.8 3.5 12/03/2006 04:40:00 13.6 2 20.2 8.8 11 2.1 18.7 6.5 13.2 1.8 21 8.8 10 8 15 165 3.6 0 3.8 3.5 12/03/2006 04:50:00 13.7 1.7 17.6 10.3 10.2 1.8 15.6 6.5 13.6 1.7 17.6 9.5 6 8 7 165 3.7 0 4.3 3.5 12/03/2006 05:00:00 13.3 1.5 17.6 9.1 10 1.6 15.6 6.5 13.2 1.6 17.2 9.1 8 7 14 165 3.8 0 4 3.5 12/03/2006 05:10:00 12.3 1.3 15.3 8.4 9.3 1.5 13.7 6.1 12.2 1.4 15.3 8.8 8 8 4 165 4 0 4.3 3.8 12/03/2006 05:20:00 12.5 1.4 16.1 9.1 9.4 1.5 13.7 5.3 12.3 1.5 16.1 8.4 7 7 11 165 4 0 4.3 4 12/03/2006 05:30:00 12.3 1.6 16.1 8.4 9.4 1.7 13.7 5.3 12.2 1.7 16.1 8.8 9 7 5 165 4 0 4.3 4 12/03/2006 05:40:00 11.9 1.6 16.4 8.8 9.4 1.9 14.9 6.1 11.7 1.6 16.8 8.4 9 9 16 165 3.9 0 4.3 3.8 12/03/2006 05:50:00 11.6 1.3 14.1 8.4 8.6 1.5 13.7 4.6 11.3 1.4 14.5 8 8 6 5 165 3.8 0 4 3.8 12/03/2006 06:00:00 11 1.3 14.1 7.6 7.7 1.2 11.1 4.9 11.1 1.2 13.7 7.6 5 7 9 165 4 0 4.3 3.8 12/03/2006 06:10:00 11.5 1.1 14.5 8.8 8.4 1.5 12.6 5.3 11.3 1.2 16.1 8.4 7 7 21 165 4.1 0 4.3 3.8 12/03/2006 06:20:00 10.9 1.1 13.7 8 7.7 1.3 11.8 4.6 11 1.3 14.1 7.6 6 7 4 165 4.2 0 4.5 4.3 12/03/2006 06:30:00 10.5 1.3 14.5 6.8 7.4 1.2 11.1 4.9 10.7 1.2 14.1 7.2 7 7 1 165 4.4 0 4.5 4.3 12/03/2006 06:40:00 9.6 0.9 11.8 7.6 6.8 1.1 10.7 4.2 9.6 1 12.2 7.2 7 6 4 165 4.4 0 4.8 3.8 12/03/2006 06:50:00 10.1 1.3 13.3 6.8 7.1 1.3 11.1 4.2 10 1.1 12.6 7.2 5 6 357 165 4.4 0.1 4.8 3.8 12/03/2006 07:00:00 9.9 1.2 12.6 6.1 6.9 1.2 10.7 3.8 9.7 1.2 12.6 6.5 4 6 2 165 4.5 0 4.8 4 12/03/2006 07:10:00 9 1.5 13 5.7 6.7 1.5 10.3 3.8 8.8 1.3 12.2 5.7 5 9 7 165 4.5 0 4.8 3.8 12/03/2006 07:20:00 9.7 1.3 13.7 6.5 7.4 1.6 12.6 4.2 9.6 1.4 13.3 6.5 6 9 16 165 4.6 0 4.8 4.3 12/03/2006 07:30:00 10.2 1.2 13.3 7.6 7.8 1.4 12.6 5.3 10 1.2 12.6 6.5 7 8 16 165 4.6 0 4.8 4.3 12/03/2006 07:40:00 8.8 1.3 12.2 5.3 6.9 1.3 10.3 3.8 8.4 1.3 11.8 5.3 4 8 8 165 4.6 0 4.8 4.3 12/03/2006 07:50:00 8.3 1.2 11.8 5.3 6.4 1.2 10.3 3.8 8.1 1.3 11.5 4.9 3 9 16 165 4.6 0.1 4.8 4.3 12/03/2006 08:00:00 8.2 1.5 11.5 4.9 6.7 2.2 12.2 3.4 7.9 1.5 11.5 3.8 358 9 347 165 4.6 0 5.2 4.3 12/03/2006 08:10:00 7.8 1.3 11.1 4.2 6.5 1.5 11.1 2.6 7.4 1.1 10.3 4.6 354 10 355 165 4.4 0 4.8 3.8 12/03/2006 08:20:00 8.2 1.2 10.7 4.6 6.6 1.7 11.5 3 7.7 1.2 10.7 4.9 357 9 8 165 4.4 0 4.5 4 12/03/2006 08:30:00 7.3 1 9.5 4.9 6.4 1 9.5 3.8 6.5 1.1 9.1 3.8 351 8 354 165 4.3 0 4.5 3.8 12/03/2006 08:40:00 7.7 1 9.9 4.2 6.7 1.1 9.5 3.8 7.1 1.1 9.9 3.4 353 8 356 165 4.1 0.1 4.5 3.8 12/03/2006 08:50:00 8.3 1.1 11.8 5.7 7.3 1.3 10.7 4.6 7.9 1 10.3 4.9 352 7 354 165 4.3 0 4.5 3.8 12/03/2006 09:00:00 8.9 1.4 11.8 5.3 7.5 1.6 11.8 3.4 8.4 1.5 11.8 4.6 353 9 358 165 4.2 0 5 3.8 12/03/2006 09:10:00 7.6 0.9 10.3 5.3 6.4 1.2 10.3 3.8 6.9 0.9 9.1 4.6 354 7 354 165 4.3 0 4.5 4.3 12/03/2006 09:20:00 7.2 1.1 11.1 4.9 6.6 1.3 11.5 3.4 6.7 1 9.9 4.6 350 7 350 165 4.1 0 4.5 3.8 12/03/2006 09:30:00 5.9 1 8 3.4 5.6 1.2 8 2.3 5.5 0.9 7.6 3.4 343 9 353 165 3.8 0 4.3 3.8 12/03/2006 09:40:00 5.4 0.7 7.2 3.8 5.4 0.7 7.2 3.4 5.4 0.7 7.6 3.8 330 11 332 165 3.6 0.1 4 3.3 12/03/2006 09:50:00 6.4 0.7 8 4.2 6.3 0.7 7.6 3.8 6.2 0.6 8 4.6 323 7 328 165 3.2 0 3.5 3 12/03/2006 10:00:00 6.7 1 9.5 4.2 6.6 1 9.1 4.2 6.5 1.1 9.5 4.2 327 11 339 165 3.2 0.1 3.5 3 12/03/2006 10:10:00 6.4 1 9.1 4.2 6.3 1 9.5 4.2 6.1 1 9.5 4.2 328 9 341 165 3.2 0.1 3.5 2.8 12/03/2006 10:20:00 6.5 0.8 9.9 4.9 6.4 0.8 9.9 4.2 6.4 0.8 9.5 4.6 332 9 338 165 3 0.1 3.3 2.8 12/03/2006 10:30:00 6.3 1.2 9.9 4.2 6.3 1.2 9.9 4.2 6.4 1.1 9.5 4.2 331 8 343 165 3.3 0 3.5 3.3 12/03/2006 10:40:00 5.2 0.7 7.6 3.8 5.2 0.8 8 3.8 5.3 0.7 7.6 4.2 333 9 334 165 3.1 0.1 3.5 2.8 12/03/2006 10:50:00 5.5 0.6 6.8 4.2 5.5 0.6 7.2 4.2 5.5 0.5 6.8 4.2 331 7 329 165 3.1 0 3.3 3 12/03/2006 11:00:00 6 0.8 8 3.8 6 0.8 8.4 3.4 6 0.7 8.4 4.6 324 8 317 165 3.2 0.1 3.5 2.8 12/03/2006 11:10:00 5.6 0.7 7.2 3.8 5.7 0.7 7.2 3.8 5.9 0.6 7.2 4.2 328 9 336 165 3 0 3 2.8 12/03/2006 11:20:00 5.9 0.7 8 4.2 6 0.7 7.6 2.6 6 0.6 7.6 4.6 328 9 317 165 3 0 3.3 2.8 12/03/2006 11:30:00 6.4 0.7 8.8 4.2 6.4 0.7 8.4 4.9 6.1 0.7 8.8 4.2 330 10 326 165 3.2 0 3.3 3 12/03/2006 11:40:00 6.6 1 8.8 4.6 6.6 0.9 8.8 4.9 6.6 0.8 9.1 4.9 340 8 336 165 3.3 0 3.5 2.6 12/03/2006 11:50:00 7.4 1.2 10.3 4.2 7.3 1.3 10.3 3.8 7.2 1.1 11.1 4.9 338 10 337 165 3.5 0.1 3.5 2.8 12/03/2006 12:00:00 6.5 0.8 9.1 4.2 5.8 1.1 8.8 3.8 6.4 0.8 8.8 4.6 350 9 356 165 3.4 0 3.5 2.8 12/03/2006 12:10:00 6.3 0.9 8.4 4.6 6.3 1 8.4 4.2 6.3 1 8.4 3.8 341 9 338 165 3.4 0 3.5 2.8 12/03/2006 12:20:00 5.5 0.8 7.6 3.8 5.5 0.8 7.2 3.4 5.9 0.8 8 3.8 343 9 357 165 3.3 0 3.5 2.6 12/03/2006 12:30:00 4.9 0.8 7.2 2.6 4.9 0.8 7.2 2.6 4.8 0.8 7.2 2.6 325 15 325 165 3.1 0.1 3.5 2.8 12/03/2006 12:40:00 6.3 0.9 10.3 4.2 6.4 0.8 9.9 4.2 5.9 1 8.8 3.4 315 11 320 165 3 0 3.3 2.8 12/03/2006 12:50:00 6.6 1 9.5 4.2 6.7 0.9 9.9 4.9 6.1 1.1 9.5 3 317 10 322 165 3 0 3.3 2.8 12/03/2006 13:00:00 5.5 1.1 8.4 2.3 5.6 1.1 8.4 1.9 5.1 0.9 8.4 3 316 12 337 165 3.1 0.1 3.5 2.6 12/03/2006 13:10:00 6 0.9 8.8 3.4 6.2 0.8 8.4 3.8 5.8 1.2 8.8 3 316 9 323 165 3.2 0 3.5 2.6 12/03/2006 13:20:00 6.1 1 8.4 3.8 6.2 0.9 8.8 3.8 5.6 1 8.4 3.4 312 10 301 165 3.2 0.1 3.5 2.3 12/03/2006 13:30:00 6.3 1 8.4 4.2 6.4 0.9 8.4 4.6 5.9 0.9 8 3.8 313 8 313 165 3 0 3.3 2.8 12/03/2006 13:40:00 6.9 0.7 8.8 4.9 6.9 0.6 8.8 4.6 5.7 0.8 8.4 3.8 306 6 295 165 3 0 3.3 2.8 12/03/2006 13:50:00 8.3 0.8 10.3 5.7 8.3 0.7 10.3 6.1 7.2 0.9 9.5 4.6 308 6 304 165 3 0 3.3 2.8 12/03/2006 14:00:00 8.8 0.9 11.8 6.1 8.7 0.9 11.5 6.5 7.2 0.9 9.5 4.9 306 6 301 165 2.9 0 3.5 2.8 12/03/2006 14:10:00 8.6 0.9 10.7 6.1 8.6 0.9 10.7 6.1 6.8 0.9 9.1 4.6 302 7 292 165 2.9 0 3 2.8 12/03/2006 14:20:00 8.1 0.9 10.7 5.3 8.1 0.9 10.7 5.7 7.7 0.9 9.9 5.3 312 7 307 165 3 0 3.3 2.8 12/03/2006 14:30:00 8 1 10.7 4.6 8 1 10.7 4.9 7.5 1 10.3 4.9 313 7 302 165 3 0 3.3 2.8 12/03/2006 14:40:00 7.7 1 9.9 4.9 7.7 0.9 9.5 5.7 7.1 1.1 9.5 3.8 311 7 312 165 3.1 0 3.3 3 12/03/2006 14:50:00 7.5 0.9 9.9 5.3 7.4 0.8 9.9 5.7 7 0.8 9.5 4.9 314 9 309 165 3.2 0 3.5 3 12/03/2006 15:00:00 7.9 1 10.7 5.7 7.9 1 10.7 5.7 7.4 0.8 9.5 5.3 313 8 296 165 3.1 0 3.3 3 12/03/2006 15:10:00 7.5 0.9 9.9 5.3 7.5 0.9 10.3 5.3 7.2 0.8 9.9 4.9 317 9 304 165 3.2 0 3.3 3 12/03/2006 15:20:00 7.8 1.1 10.7 4.6 7.7 1.1 10.3 4.6 6.9 1.1 9.9 3.8 310 10 314 165 3.1 0 3.3 3 12/03/2006 15:30:00 7.6 1.2 10.7 4.9 7.6 1.1 10.7 4.9 6.7 1 9.9 3.8 311 10 300 165 3 0 3.3 2.8 12/03/2006 15:40:00 9.6 1.2 13.3 6.5 9.5 1.2 13 6.1 7.7 1.4 12.2 4.6 297 8 293 165 2.9 0 3 2.8 12/03/2006 15:50:00 10.4 1.3 13.7 7.2 10.4 1.3 13.7 7.2 8 1.3 12.2 5.3 297 6 296 165 2.8 0 3 2.6 12/03/2006 16:00:00 9.6 1.3 12.6 6.5 9.6 1.3 12.6 6.5 7.7 1.2 11.1 4.9 300 8 297 165 2.9 0 3 2.6 12/03/2006 16:10:00 8.4 1 10.7 6.1 8.4 1 10.3 6.1 7.1 1 10.3 4.6 305 8 286 165 2.9 0 3 2.6 12/03/2006 16:20:00 7.9 0.9 10.3 4.6 7.8 0.9 9.9 4.9 7.2 1 9.5 4.6 311 8 315 165 2.9 0 3 2.6 12/03/2006 16:30:00 8.9 1.7 13.3 5.7 8.8 1.7 13.3 5.3 7.6 1.5 11.8 4.2 306 8 305 165 2.9 0 3 2.6 12/03/2006 16:40:00 11.9 1.4 15.3 8.4 11.9 1.4 15.3 8.4 9.4 1.3 14.1 6.5 301 6 304 165 2.9 0 3 2.6 12/03/2006 16:50:00 12.4 1.7 16.1 8 12.3 1.7 16.1 7.6 10 1.6 15.6 6.5 302 6 300 165 2.7 0 2.8 2.6 12/03/2006 17:00:00 13.2 1.5 16.8 9.5 13.1 1.5 16.8 9.1 10.6 1.5 14.5 6.8 304 6 307 165 2.7 0 2.8 2.6 12/03/2006 17:10:00 13.3 1.5 17.2 8.4 13.2 1.6 17.2 8.8 10.4 1.3 14.5 7.2 302 6 296 165 2.6 0 2.8 2.3 12/03/2006 17:20:00 12.9 1.4 15.3 8.8 12.8 1.5 15.6 8.4 10.2 1.5 14.1 6.1 302 6 304 165 2.4 0 2.8 2.3 12/03/2006 17:30:00 13.2 1.2 16.1 9.9 13.2 1.3 16.1 9.9 10.5 1.3 14.1 7.2 303 6 310 165 2.4 0 2.8 2.3 12/03/2006 17:40:00 13.4 1.6 16.1 9.1 13.4 1.6 16.4 8.8 10.3 1.3 13.3 6.5 302 5 308 165 2.4 0 2.6 2.3 12/03/2006 17:50:00 13.3 1.3 15.6 9.5 13.3 1.3 15.6 9.5 10.2 1.1 13.3 6.8 300 6 301 165 2.4 0 2.6 2.3 12/03/2006 18:00:00 13.6 1.1 17.2 10.3 13.6 1.1 17.2 10.7 10.7 1.3 14.1 7.2 303 5 305 165 2.4 0 2.6 2.3 12/03/2006 18:10:00 14.1 1.3 17.2 10.7 14.1 1.3 17.6 10.7 11.1 1.3 14.1 7.2 304 5 298 165 2.4 0 2.6 2.3 12/03/2006 18:20:00 13.7 1.4 17.2 9.5 13.7 1.5 17.2 9.1 10.6 1.3 14.5 6.5 300 6 295 165 2.4 0 2.6 2.3 12/03/2006 18:30:00 13.3 1.5 16.4 9.1 13.3 1.5 16.4 8.4 10.5 1.5 15.6 6.8 299 6 299 165 2.5 0 2.8 2.3 12/03/2006 18:40:00 13.4 1.5 16.8 8.8 13.4 1.5 16.8 9.5 10.6 1.5 14.5 6.5 298 6 288 165 2.5 0 2.8 2.3 12/03/2006 18:50:00 13.1 1.4 16.8 9.5 13.1 1.4 16.8 9.5 10.3 1.3 14.5 6.5 301 6 296 165 2.5 0 2.8 2.3 12/03/2006 19:00:00 13.3 1.5 17.6 8 13.3 1.6 17.2 8 10.1 1.3 14.1 6.8 299 6 298 165 2.5 0 2.8 2.3 12/03/2006 19:10:00 12.6 1.6 17.9 9.1 12.6 1.6 17.9 8.8 11 1.8 16.1 6.8 293 6 298 165 2.4 0 2.6 2.3 12/03/2006 19:20:00 13.1 1.5 17.6 9.1 13.1 1.5 17.6 9.1 10.7 1.6 17.2 6.8 294 6 298 165 2.4 0 2.8 2.3 12/03/2006 19:30:00 13 1.3 17.2 9.9 13 1.4 16.8 9.5 9.9 1.3 14.1 6.8 298 6 302 165 2.4 0 2.6 2.3 12/03/2006 19:40:00 13 1 15.3 10.7 13 1 15.6 10.7 10.1 1.3 14.1 7.2 300 6 307 165 2.4 0 2.6 2.3 12/03/2006 19:50:00 13.8 1.5 16.8 9.5 13.8 1.5 17.2 9.9 11.6 1.5 14.9 6.1 304 5 302 165 2.4 0 2.6 2.3 12/03/2006 20:00:00 12.9 1.5 16.1 9.1 12.8 1.5 16.4 9.1 10.9 1.5 14.9 7.6 305 6 310 165 2.4 0 2.8 2.3 12/03/2006 20:10:00 14.8 1.5 17.6 9.9 14.8 1.5 17.9 10.3 11.9 1.5 15.6 7.2 303 5 301 165 2.4 0 2.6 2.3 12/03/2006 20:20:00 14.9 1.3 17.9 11.1 14.9 1.3 17.6 11.1 11.2 1.2 14.9 7.6 300 5 293 165 2.4 0 2.6 2.3 12/03/2006 20:30:00 15.3 1 17.2 11.8 15.3 1.1 17.6 11.5 11.1 1.1 16.1 8.4 298 4 294 165 2.3 0 2.6 2.3 12/03/2006 20:40:00 14.1 1.5 18.3 9.9 14 1.5 18.3 9.5 10.5 1.2 14.9 6.8 297 5 306 165 2.3 0 2.6 2.1 12/03/2006 20:50:00 13.8 1.4 16.8 9.9 13.8 1.4 16.8 9.5 10.4 1.4 15.6 6.8 295 5 293 165 2.1 0 2.3 1.8 12/03/2006 21:00:00 13.4 1.3 16.4 10.3 13.4 1.3 16.8 9.9 10.1 1.3 15.3 7.2 297 5 292 165 2 0 2.3 1.8 12/03/2006 21:10:00 13.9 1.3 16.4 10.7 13.9 1.3 16.4 10.7 10.7 1.3 14.5 8 300 5 296 165 1.9 0 2.1 1.8 12/03/2006 21:20:00 13.3 1.1 15.6 9.9 13.3 1.1 15.6 9.5 11 1.3 14.1 6.8 305 5 307 165 1.9 0 2.1 1.8 12/03/2006 21:30:00 12.8 1.3 15.3 9.1 12.8 1.3 15.6 9.1 10.7 1.5 15.3 7.2 304 5 304 165 1.9 0 2.1 1.8 12/03/2006 21:40:00 12.8 1.1 16.1 9.9 12.8 1.2 16.1 9.5 11.2 1.5 14.9 7.2 306 6 310 165 1.8 0 1.8 1.8 12/03/2006 21:50:00 13.8 1 15.6 10.3 13.8 1.1 15.6 9.9 12.2 1.2 15.6 8.8 307 4 302 165 1.8 0 1.8 1.6 12/03/2006 22:00:00 14 0.7 15.6 12.2 14 0.7 15.6 12.2 12.1 1.1 14.9 8.8 305 3 303 165 1.8 0 1.8 1.6 12/03/2006 22:10:00 13.3 1 15.3 10.3 13.3 1 15.3 9.5 11.6 1.1 14.1 8 306 4 305 165 1.8 0 1.8 1.6 12/03/2006 22:20:00 13 1 14.9 10.3 13 1.1 14.9 10.3 10.9 1.2 14.9 7.6 305 4 307 165 1.8 0 1.8 1.6 12/03/2006 22:30:00 13.7 1 16.1 10.3 13.7 1 16.1 9.9 12.3 1.2 16.1 8.4 307 5 307 165 1.8 0 1.8 1.8 12/03/2006 22:40:00 13.8 1 16.1 10.3 13.8 1.1 16.1 9.9 12.3 1.2 14.5 7.6 307 4 307 165 1.8 0 1.8 1.6 12/03/2006 22:50:00 13.4 0.7 15.3 11.1 13.4 0.8 15.3 10.7 12 1.1 14.1 8 307 4 310 165 1.8 0 1.8 1.6 12/03/2006 23:00:00 12.4 0.9 14.1 8.8 12.4 1 14.9 8.4 11.4 1.3 15.3 8 309 4 311 165 1.8 0 1.8 1.6 12/03/2006 23:10:00 11.9 0.8 13.7 9.5 11.8 0.8 13.3 9.5 11.1 0.9 13 7.6 311 4 312 165 1.8 0 1.8 1.6 12/03/2006 23:20:00 12.1 0.8 13.7 9.5 12 0.8 13.7 9.1 10.9 1 13 8 310 4 307 165 1.8 0 1.8 1.8 12/03/2006 23:30:00 12.7 0.8 14.5 10.3 12.6 0.9 14.5 9.9 11 1.2 14.1 8 310 4 304 165 1.9 0 2.1 1.8 12/03/2006 23:40:00 12.2 0.9 14.1 9.1 12.1 1 14.1 8.8 10.7 1 13.3 7.6 310 4 306 165 2 0 2.3 1.8 12/03/2006 23:50:00 11.4 0.9 13.3 8.8 11.3 0.9 13.3 8.4 9.3 1.1 11.8 6.5 307 5 309 165 2 0 2.3 1.8 12/04/2006 00:00:00 11 1 13 8 10.9 1 13 8 8.9 1.1 11.8 6.5 306 5 301 165 2 0 2.3 1.8 12/04/2006 00:10:00 10.4 1 13 8 10.4 1 12.6 8 8 1.1 11.5 5.3 303 6 309 165 2 0 2.3 1.8 12/04/2006 00:20:00 10.4 0.9 11.8 8.4 10.4 0.8 12.2 8.4 7.8 0.9 10.3 5.7 302 5 297 165 2 0 2.3 1.8 12/04/2006 00:30:00 9.9 0.9 13 8 9.9 0.9 12.6 7.6 7.9 1.1 11.1 5.7 305 5 301 165 2 0 2.3 1.8 12/04/2006 00:40:00 10.3 0.8 11.8 7.6 10.3 0.8 12.2 8 8 0.9 10.3 5.3 306 4 312 165 1.9 0 2.1 1.8 12/04/2006 00:50:00 10.7 0.9 13 8.4 10.7 0.9 12.6 8.4 8.7 1 11.1 6.1 306 5 307 165 1.9 0 2.1 1.8 12/04/2006 01:00:00 11.7 1 13.7 9.1 11.6 1 13.3 8.8 9.5 1.2 12.2 6.8 306 4 306 165 1.9 0 1.8 1.8 12/04/2006 01:10:00 11.1 1.2 13.7 7.6 11.1 1.2 13.7 7.6 8.9 1 12.2 6.1 307 5 302 165 1.8 0 1.8 1.6 12/04/2006 01:20:00 10.8 1.1 13 7.6 10.7 1.1 13.3 7.6 8.9 1.2 12.2 6.1 307 5 313 165 1.8 0 1.8 1.8 12/04/2006 01:30:00 9.6 0.8 11.8 6.5 9.6 0.8 11.8 6.5 8 1 10.7 5.7 307 5 301 165 1.8 0 1.8 1.6 12/04/2006 01:40:00 9.5 0.8 11.5 6.8 9.6 0.8 11.5 7.2 7.1 0.8 9.5 5.3 301 5 300 165 1.9 0 2.1 1.8 12/04/2006 01:50:00 8.9 0.6 10.3 7.2 9 0.6 10.3 6.8 6.8 0.8 9.5 4.6 298 4 304 165 1.9 0 2.3 1.8 12/04/2006 02:00:00 8.9 1 11.1 6.1 8.9 1 11.1 6.1 6.8 0.9 9.9 4.6 302 6 303 165 2 0 2.3 1.8 12/04/2006 02:10:00 9 0.7 10.7 7.2 9 0.8 11.1 7.2 6.6 0.8 9.5 4.9 300 4 291 165 2 0 2.3 1.4 12/04/2006 02:20:00 9.9 0.7 11.5 8 9.9 0.7 11.5 8 7.2 0.7 9.9 5.3 299 4 301 165 2 0 2.3 1.8 12/04/2006 02:30:00 9.3 1 11.8 6.8 9.4 1 11.5 6.5 7.2 0.9 9.9 4.9 300 5 300 165 2 0.1 2.3 1.4 12/04/2006 02:40:00 9.3 0.9 11.5 6.8 9.3 0.9 11.5 7.2 7 1 9.1 4.6 298 5 302 165 2 0.1 2.3 1.4 12/04/2006 02:50:00 9.1 0.5 10.3 7.2 9.1 0.5 10.3 7.2 6.4 0.6 8.4 4.9 299 3 299 165 2 0 2.3 1.8 12/04/2006 03:00:00 8.1 0.6 9.9 6.8 8.2 0.6 9.5 6.8 6.2 0.8 9.1 4.9 299 5 300 165 2 0 2.3 1.8 12/04/2006 03:10:00 7.6 0.5 8.8 5.3 7.7 0.5 9.1 5.7 5.6 0.6 7.2 4.2 300 3 299 165 2.1 0 2.3 1.8 12/04/2006 03:20:00 8.1 0.6 9.5 6.5 8.2 0.6 9.5 6.5 5.8 0.6 7.6 4.2 300 4 300 165 2 0 2.3 1.8 12/04/2006 03:30:00 8.6 0.6 10.7 6.8 8.7 0.6 10.7 6.8 6.6 0.9 9.5 4.9 298 5 306 165 2.1 0 2.3 1.8 12/04/2006 03:40:00 9.4 0.8 11.1 7.2 9.4 0.8 11.5 7.2 6.8 0.8 9.5 4.9 302 3 304 165 2 0 2.3 1.8 12/04/2006 03:50:00 9.3 0.7 11.1 7.6 9.4 0.7 11.1 7.2 7.2 0.9 10.3 4.9 298 5 300 165 2 0 2.3 1.8 12/04/2006 04:00:00 8.7 1.3 12.6 4.6 8.7 1.4 12.2 4.9 7.5 1.2 10.7 4.2 310 7 298 165 2.1 0 2.3 1.8 12/04/2006 04:10:00 8 0.8 10.7 5.7 7.9 0.8 10.7 5.7 6.8 1 9.5 4.9 308 6 308 165 2.2 0 2.3 2.1 12/04/2006 04:20:00 8.4 1 12.2 6.1 8.4 1 12.2 6.1 6.6 1 9.5 4.2 305 5 300 165 2.1 0 2.3 2.1 12/04/2006 04:30:00 8.2 0.6 9.9 6.5 8.2 0.6 9.9 6.5 6.9 0.7 8.4 5.3 308 4 304 165 2.1 0 2.3 2.1 12/04/2006 04:40:00 8 0.5 9.1 5.7 7.9 0.5 9.1 6.1 7.1 0.6 8.4 5.3 310 4 307 165 2.3 0 2.6 2.1 12/04/2006 04:50:00 7.6 0.8 9.1 4.9 7.5 0.8 9.1 5.7 6.3 0.8 8 3.8 307 5 307 165 2.3 0 2.6 2.1 12/04/2006 05:00:00 7.4 1.1 9.5 4.9 7.4 1.1 9.5 4.9 5.6 0.9 8.4 3.4 301 5 304 165 2.4 0 2.6 2.3 12/04/2006 05:10:00 7.8 1 9.9 5.7 7.8 0.9 9.9 5.7 5.8 0.7 8 3.4 301 4 297 165 2.4 0 2.6 2.3 12/04/2006 05:20:00 7.2 1 9.1 4.2 7.3 1 9.1 4.6 5.5 0.8 8 3.4 302 5 298 165 2.4 0 2.6 2.3 12/04/2006 05:30:00 6.2 0.7 9.1 4.9 6.4 0.7 9.1 4.9 4.6 0.6 6.8 3.4 299 3 300 165 2.4 0 2.6 2.1 12/04/2006 05:40:00 5.1 0.5 6.1 3.8 5.2 0.5 6.5 3.4 4.1 0.6 6.1 2.6 295 4 295 165 2.4 0.1 2.8 2.1 12/04/2006 05:50:00 4.5 0.6 5.7 3 4.5 0.6 6.1 3 3.9 0.7 5.7 2.3 290 7 295 165 2.5 0.1 2.8 2.1 12/04/2006 06:00:00 3.6 0.7 4.9 2.3 3.7 0.7 5.3 2.3 3 0.5 4.6 1.9 298 4 297 165 2.6 0 2.8 2.1 12/04/2006 06:10:00 2.9 0.3 3.8 2.3 3 0.3 3.8 2.3 3.2 0.3 4.2 2.3 282 6 291 165 2.6 0 2.8 2.3 12/04/2006 06:20:00 2.9 0.2 3.4 2.3 3 0.2 3.4 2.3 3 0.4 3.8 1.9 288 6 284 165 2.6 0.1 2.8 2.1 12/04/2006 06:30:00 2.2 0.3 3 1.5 2.4 0.3 3 1.9 2.5 0.4 3 1.5 291 5 284 165 2.7 0 2.8 2.3 12/04/2006 06:40:00 2.2 0.3 3.4 1.5 2.3 0.3 3.4 1.5 2.8 0.3 3.4 2.3 280 5 291 165 2.7 0 3 2.3 12/04/2006 06:50:00 1.6 0.4 2.3 0.7 1.8 0.4 2.6 0.7 2.3 0.3 3 1.5 283 5 277 165 2.7 0 3 2.3 12/04/2006 07:00:00 1.2 0.2 1.9 0.7 1.3 0.2 1.9 0.7 1.9 0.2 2.6 1.5 277 5 274 165 2.7 0 3 2.6 12/04/2006 07:10:00 0.8 0.4 1.5 0.4 0.8 0.4 1.5 0.4 1.3 0.4 2.3 0.4 293 7 285 165 2.7 0 3 2.3 12/04/2006 07:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0.2 1.1 0.4 300 0 165 165 2.6 0 2.8 2.1 12/04/2006 07:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 300 0 165 165 2.6 0.1 2.8 2.1 12/04/2006 07:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0.1 0.7 0.4 284 22 165 165 2.6 0.1 2.8 2.1 12/04/2006 07:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.5 0.2 1.1 0.4 209 12 165 165 2.5 0 2.8 2.3 12/04/2006 08:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 204 0 165 165 2.4 0 2.6 2.3 12/04/2006 08:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.5 0.2 1.1 0.4 205 0 165 165 2.3 0 2.6 2.1 12/04/2006 08:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.7 0.3 1.1 0.4 205 0 165 165 2.2 0 2.3 1.8 12/04/2006 08:30:00 0.4 0.2 1.1 0.4 0.4 0.2 1.1 0.4 0.6 0.4 1.9 0.4 189 21 152 165 2.4 0.1 2.8 2.1 12/04/2006 08:40:00 0.6 0.4 1.5 0.4 0.5 0.3 1.5 0.4 1.1 0.4 1.9 0.4 153 0 152 165 2.4 0.1 3 2.1 12/04/2006 08:50:00 1.2 0.5 2.3 0.4 1.1 0.5 1.9 0.4 1.5 0.4 2.3 0.7 152 3 149 165 2.1 0 2.6 2.1 12/04/2006 09:00:00 1.6 0.4 2.3 0.7 1.7 0.4 2.6 0.7 1.9 0.3 2.6 1.1 122 9 115 165 2.4 0 2.8 2.3 12/04/2006 09:10:00 0.9 0.3 1.9 0.4 0.7 0.3 1.5 0.4 1.5 0.3 1.9 0.4 160 13 147 165 2.3 0 2.6 2.1 12/04/2006 09:20:00 0.8 0.4 1.9 0.4 0.6 0.4 1.5 0.4 1.2 0.2 1.5 0.7 157 7 153 165 2.1 0 2.3 1.8 12/04/2006 09:30:00 1.3 0.5 2.3 0.4 1.2 0.5 2.3 0.4 1.7 0.4 2.6 0.7 152 5 155 165 2.1 0 2.6 2.1 12/04/2006 09:40:00 2 0.5 3 0.7 2 0.5 3 0.7 2.2 0.4 3 1.5 138 3 133 165 2.2 0 2.6 2.1 12/04/2006 09:50:00 2.1 0.5 3.4 1.1 2.1 0.5 3.4 1.1 2.4 0.4 3 1.5 145 4 143 165 2.3 0 2.6 2.1 12/04/2006 10:00:00 2.5 0.4 3.4 1.1 2.4 0.4 3.4 1.5 2.8 0.4 3.8 1.5 149 5 150 165 2.2 0 2.6 1.8 12/04/2006 10:10:00 2.6 0.4 3.8 1.5 2.5 0.4 3.4 1.9 2.8 0.3 3.8 1.9 149 5 154 165 2.3 0 2.6 1.8 12/04/2006 10:20:00 2.5 0.5 3.8 1.5 2.4 0.5 3.8 1.5 2.8 0.4 3.8 1.9 148 9 143 165 2.3 0 2.6 1.8 12/04/2006 10:30:00 1.8 0.5 2.6 0.4 1.7 0.5 2.6 0.4 2.3 0.4 3 1.1 163 6 161 165 2.4 0 2.6 1.8 12/04/2006 10:40:00 2 0.5 3.4 0.4 2.1 0.6 3.8 0.7 2.1 0.5 3.8 1.1 125 10 135 165 2.4 0 2.6 2.1 12/04/2006 10:50:00 2 0.5 3.4 1.1 2.3 0.5 3.4 1.1 2.4 0.4 3.4 1.5 112 8 112 165 2.4 0 2.6 2.3 12/04/2006 11:00:00 2.2 0.4 3.4 1.1 2.4 0.5 3.4 1.1 2.6 0.4 3.4 1.5 117 7 107 165 2.4 0 2.6 2.3 12/04/2006 11:10:00 2.6 0.4 3.4 1.1 2.8 0.4 3.4 1.1 2.9 0.4 3.8 1.9 116 4 117 165 2.5 0.1 2.8 1.8 12/04/2006 11:20:00 2.4 0.3 3 1.5 2.6 0.4 3.4 1.5 2.7 0.3 3.8 1.5 117 4 116 165 2.6 0 2.8 2.1 12/04/2006 11:30:00 2.4 0.4 3.4 1.5 2.6 0.4 3.8 1.5 2.6 0.4 3.8 1.5 123 7 125 165 2.7 0 2.8 2.1 12/04/2006 11:40:00 2.3 0.3 3.4 1.5 2.4 0.4 3.4 1.5 2.7 0.4 3.8 1.5 125 5 121 165 2.7 0 2.8 2.3 12/04/2006 11:50:00 1.6 0.6 2.6 0.4 1.7 0.6 3 0.4 2.1 0.4 3 0.7 122 9 118 165 2.8 0.2 3.3 2.3 12/04/2006 12:00:00 0.5 0.3 1.5 0.4 0.4 0.2 1.5 0.4 1 0.6 2.3 0.4 114 13 127 165 3.5 0.4 4.5 2.8 12/04/2006 12:10:00 0.5 0.2 1.5 0.4 0.4 0.2 1.5 0.4 0.6 0.3 1.5 0.4 71 56 357 165 4.4 0.1 4.8 3.8 12/04/2006 12:20:00 1.3 0.5 2.3 0.4 1 0.6 2.3 0.4 1.5 0.6 2.6 0.4 5 13 12 165 3.8 0.2 4.8 3 12/04/2006 12:30:00 1.1 0.6 2.3 0.4 1.2 0.7 2.3 0.4 1.5 0.7 2.6 0.4 79 39 34 165 3.1 0.2 3.8 2.6 12/04/2006 12:40:00 1.2 0.4 2.3 0.4 1.2 0.5 2.6 0.4 1.8 0.3 2.6 1.1 131 8 137 165 3 0.1 3.5 2.6 12/04/2006 12:50:00 1.4 0.3 2.3 0.7 1.5 0.3 2.3 0.7 2 0.3 2.6 1.1 127 15 117 165 2.9 0.2 3.3 2.3 12/04/2006 13:00:00 1.7 0.3 2.6 0.4 1.8 0.4 2.6 0.4 2.2 0.3 3 1.5 133 7 128 165 2.7 0.2 3.3 2.3 12/04/2006 13:10:00 1.2 0.6 2.6 0.4 1.1 0.7 2.3 0.4 1.7 0.5 2.6 0.4 148 11 154 165 2.9 0.1 3.3 2.6 12/04/2006 13:20:00 0.9 0.4 2.3 0.4 0.7 0.4 1.9 0.4 1.5 0.5 2.6 0.4 173 5 169 165 3.2 0.3 3.8 2.6 12/04/2006 13:30:00 0.4 0.1 1.5 0.4 0.4 0.1 1.1 0.4 0.4 0.2 1.5 0.4 174 1 173 165 4.1 0.1 4.5 3.5 12/04/2006 13:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 174 1 165 165 4.4 0 4.8 4.3 12/04/2006 13:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 211 49 165 165 3.8 0.2 4.5 3.3 12/04/2006 14:00:00 0.4 0.2 1.5 0.4 0.4 0.2 1.5 0.4 0.6 0.5 1.9 0.4 4 112 145 165 3.5 0.2 3.8 2.8 12/04/2006 14:10:00 0.4 0.2 1.1 0.4 0.4 0.1 1.1 0.4 0.7 0.4 2.3 0.4 165 5 146 165 3 0.2 4 2.6 12/04/2006 14:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0.1 0.7 0.4 167 0 165 165 2.9 0 3.3 2.3 12/04/2006 14:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 167 0 165 165 2.9 0 3 2.6 12/04/2006 14:40:00 0.5 0.3 1.1 0.4 0.4 0.2 1.1 0.4 0.8 0.6 1.9 0.4 168 1 169 165 2.7 0.1 3 2.3 12/04/2006 14:50:00 0.7 0.4 1.9 0.4 0.6 0.3 1.5 0.4 1.4 0.4 2.3 0.4 166 2 165 165 2.7 0.1 3.3 2.1 12/04/2006 15:00:00 0.5 0.2 1.5 0.4 0.5 0.3 1.5 0.4 1.4 0.2 2.3 0.7 151 12 126 165 2.7 0 3 2.6 12/04/2006 15:10:00 0.9 0.5 2.3 0.4 0.9 0.5 2.3 0.4 1.6 0.4 2.6 0.4 134 11 126 165 2.7 0 2.8 2.3 12/04/2006 15:20:00 2.5 0.5 3.4 0.7 2.5 0.5 3.4 0.7 2.9 0.5 3.8 1.1 147 12 153 165 2.4 0.2 2.8 1.8 12/04/2006 15:30:00 3.1 0.4 4.2 2.3 3 0.4 3.8 2.3 3.4 0.4 4.6 2.3 164 6 165 165 2.1 0 2.3 1.8 12/04/2006 15:40:00 3.5 0.5 4.6 2.3 3.4 0.5 4.6 2.3 3.9 0.5 4.9 2.6 162 7 165 165 2.1 0 2.3 1.8 12/04/2006 15:50:00 3.8 0.3 4.6 3 3.7 0.3 4.6 3 4.1 0.4 4.9 3 171 6 159 165 1.9 0.1 2.3 1.4 12/04/2006 16:00:00 3.7 0.4 4.9 2.6 3.6 0.4 4.6 2.3 4 0.4 4.9 3 173 7 171 165 1.5 0 1.8 1.1 12/04/2006 16:10:00 4.9 0.8 6.8 3 4.7 0.8 6.5 3 5.1 0.9 7.2 3.4 168 7 165 165 1.5 0.1 1.6 0.9 12/04/2006 16:20:00 3.7 0.8 5.7 1.9 3.7 0.7 5.3 1.9 4 0.8 5.7 2.3 186 10 185 165 1.4 0.1 1.6 0.9 12/04/2006 16:30:00 2.4 0.4 3.8 1.5 2.5 0.4 3.8 1.5 2.9 0.4 3.8 1.9 184 6 192 165 1.4 0.1 1.6 0.9 12/04/2006 16:40:00 3.5 1 5.7 1.5 3.5 1 5.7 1.5 3.8 1 5.7 2.3 177 8 188 165 1.4 0 1.6 0.9 12/04/2006 16:50:00 3.9 0.5 5.3 2.6 3.9 0.5 4.9 2.6 4.3 0.4 5.3 3 183 7 171 165 1.6 0 1.8 1.4 12/04/2006 17:00:00 4 0.3 4.9 3 3.9 0.3 4.9 3 4.1 0.3 4.9 3.4 180 4 181 165 1.5 0 2.3 1.4 12/04/2006 17:10:00 3.4 0.7 4.9 1.9 3.3 0.7 4.6 1.9 3.5 0.8 5.3 2.3 177 5 173 165 1.5 0 1.6 1.4 12/04/2006 17:20:00 2.8 0.5 4.2 1.1 2.7 0.5 3.8 0.7 3 0.5 4.2 1.1 168 7 172 165 1.5 0 1.6 1.4 12/04/2006 17:30:00 4.8 1.1 7.2 2.3 4.8 1.1 7.2 2.3 5.1 1.1 8 2.6 153 6 154 165 1.4 0 1.6 1.1 12/04/2006 17:40:00 6.2 0.7 8 3.8 6.1 0.7 8 4.2 6.3 0.8 8 4.2 160 11 157 165 1.2 0 1.4 1.1 12/04/2006 17:50:00 6.5 1 8.4 4.6 6.4 0.9 8 4.6 6.8 1 8.4 4.2 165 10 163 165 1.2 0 1.4 1.1 12/04/2006 18:00:00 6.9 0.5 8 5.7 6.6 0.5 7.6 5.3 7.1 0.6 8.4 5.7 165 13 154 165 1.2 0 1.4 0.9 12/04/2006 18:10:00 5.1 0.5 6.1 3.8 4.9 0.4 5.7 3.8 5.3 0.5 6.5 4.2 173 4 172 165 1.1 0 1.4 0.9 12/04/2006 18:20:00 5.7 0.9 8 3.8 5.5 0.9 7.6 3.8 5.8 1 8 3.8 165 5 165 165 1.1 0 1.4 0.9 12/04/2006 18:30:00 7.1 0.4 8 5.7 6.9 0.4 7.6 5.7 7.3 0.5 8.4 5.7 163 9 165 165 1.1 0 1.4 0.9 12/04/2006 18:40:00 6.5 0.5 7.6 4.9 6.3 0.5 7.6 4.9 6.6 0.6 8 4.9 166 12 170 165 1 0 1.4 0.9 12/04/2006 18:50:00 7.6 0.5 8.8 6.1 7.4 0.4 8.4 5.7 7.8 0.5 8.8 6.5 167 7 165 165 1.1 0 1.4 0.9 12/04/2006 19:00:00 8.6 0.9 10.3 6.5 8.3 0.8 9.9 6.1 8.8 1 10.7 6.5 166 12 165 165 1.2 0 1.4 0.9 12/04/2006 19:10:00 9 0.5 9.9 7.2 8.7 0.5 9.9 7.2 8.9 0.6 10.3 7.2 166 8 165 165 1.2 0 1.4 0.7 12/04/2006 19:20:00 8.3 0.5 9.5 6.8 8 0.5 9.1 6.8 8.5 0.6 9.9 6.8 168 4 166 165 1.1 0 1.4 0.7 12/04/2006 19:30:00 6.8 0.5 8.4 5.3 6.6 0.5 8 5.3 6.8 0.6 8 4.9 166 10 165 165 1.1 0 1.4 0.7 12/04/2006 19:40:00 6.4 0.5 7.6 5.3 6.3 0.4 7.2 5.3 6.5 0.5 7.6 5.3 163 6 165 165 1.1 0 1.4 0.7 12/04/2006 19:50:00 6.1 0.6 7.2 4.2 6.1 0.6 7.2 4.2 6.4 0.7 7.6 4.2 156 9 157 165 1.1 0 1.4 0.7 12/04/2006 20:00:00 5.6 0.5 6.8 4.6 5.5 0.5 6.8 4.6 5.8 0.5 7.2 4.6 156 5 157 165 1.1 0 1.4 0.7 12/04/2006 20:10:00 5.1 0.5 6.1 3.8 5 0.5 6.1 4.2 5.1 0.5 6.5 4.2 160 5 157 165 1.1 0 1.4 0.7 12/04/2006 20:20:00 4.7 0.5 5.7 3 4.6 0.4 5.3 3 4.9 0.5 5.7 3.4 160 4 160 165 1 0 1.4 0.7 12/04/2006 20:30:00 6.1 0.9 8 3.8 6.1 0.9 8 4.2 6.2 0.8 7.6 3.8 157 6 148 165 0.9 0 1.4 0.4 12/04/2006 20:40:00 6.1 0.5 7.6 4.2 6 0.4 7.2 4.2 6.3 0.5 7.6 4.9 163 4 159 165 0.5 0.1 0.9 -0.1 12/04/2006 20:50:00 4.4 0.7 5.7 3 4.3 0.7 5.7 3 4.6 0.7 6.1 3 165 0 165 165 0.4 0 0.7 -0.3 12/04/2006 21:00:00 3.1 0.5 4.2 2.3 3 0.5 3.8 1.9 3.3 0.4 4.2 2.6 165 0 165 165 0.5 0 0.9 -0.1 12/04/2006 21:10:00 2.4 0.6 4.6 1.1 2.3 0.6 4.6 1.5 2.6 0.5 4.6 1.9 165 0 165 165 0.6 0.1 0.9 -0.1 12/04/2006 21:20:00 3.6 0.7 5.3 1.9 3.5 0.7 5.3 1.9 3.8 0.5 5.3 2.3 159 5 162 165 0.8 0.1 0.9 0.2 12/04/2006 21:30:00 4.3 0.8 6.1 1.9 4.3 0.8 5.7 1.9 4.6 0.7 6.5 2.3 150 11 150 165 0.8 0 0.9 0.7 12/04/2006 21:40:00 2.8 0.9 4.9 1.1 2.8 0.8 4.9 1.1 3.2 0.6 4.6 1.5 154 12 151 165 0.8 0 1.1 0.9 12/04/2006 21:50:00 3.2 1.3 6.1 0.7 3.1 1.3 6.1 0.4 3.4 1.1 6.1 1.5 141 11 137 165 0.9 0 1.1 0.9 12/04/2006 22:00:00 4 1.2 6.8 1.9 4 1.2 7.2 1.9 4.1 1.2 6.5 1.5 132 8 129 165 1.1 0 1.4 0.9 12/04/2006 22:10:00 3.7 0.7 4.9 1.9 3.7 0.7 4.9 2.3 3.9 0.6 5.3 2.6 135 6 138 165 1 0 1.4 0.9 12/04/2006 22:20:00 3.1 0.6 4.6 1.5 3.1 0.7 4.6 1.9 3.3 0.7 4.9 1.9 124 8 130 165 1.1 0 1.4 0.9 12/04/2006 22:30:00 3.6 0.5 4.9 2.3 3.7 0.6 4.9 2.3 3.6 0.6 4.9 2.3 115 4 113 165 1.1 0 1.4 0.9 12/04/2006 22:40:00 5.1 0.9 7.2 3.4 5.2 0.9 7.6 3.8 5.1 0.9 7.6 3.4 117 5 117 165 1.4 0 1.6 1.1 12/04/2006 22:50:00 6.4 0.6 8 4.9 6.6 0.6 8 4.9 6.3 0.7 8 4.6 119 7 111 165 1.5 0 1.6 1.4 12/04/2006 23:00:00 6.7 0.5 8 5.3 6.8 0.5 8 4.9 6.6 0.6 8 4.6 121 5 123 165 1.4 0 2.1 1.4 12/04/2006 23:10:00 6 0.6 7.6 4.2 6.1 0.6 7.6 4.2 5.9 0.6 8 4.2 115 6 119 165 1.4 0 1.6 1.4 12/04/2006 23:20:00 6.3 0.6 7.6 4.2 6.5 0.6 8 4.6 6.3 0.6 8 4.2 114 5 114 165 1.4 0 1.6 1.4 12/04/2006 23:30:00 7.4 0.8 9.1 5.3 7.6 0.8 9.5 5.3 7.3 0.7 8.8 4.9 116 5 114 165 1.5 0 1.8 1.4 12/04/2006 23:40:00 8.3 0.5 9.9 6.8 8.6 0.4 9.9 7.2 8.1 0.6 9.5 5.7 113 3 118 165 1.8 0 1.8 1.6 12/04/2006 23:50:00 7.8 0.6 9.1 5.7 8.1 0.6 9.1 5.7 7.2 0.7 8.8 5.3 104 4 105 165 1.8 0 1.8 1.6 12/05/2006 00:00:00 7.2 0.6 8.8 5.3 7.5 0.6 9.1 5.7 6.7 0.8 8.8 4.6 105 5 91 165 1.9 0 2.1 1.6 12/05/2006 00:10:00 7.9 0.8 9.9 5.7 8.1 0.8 10.3 6.1 7.4 0.9 9.5 4.9 102 5 106 165 1.8 0 1.8 1.6 12/05/2006 00:20:00 8.5 0.8 10.7 6.5 8.8 0.8 11.1 6.5 8 1 10.3 4.9 104 6 91 165 1.8 0 1.8 1.6 12/05/2006 00:30:00 8.8 0.8 11.1 6.1 9 0.8 11.5 6.5 8.1 1 10.3 6.1 109 6 106 165 1.7 0 1.8 1.1 12/05/2006 00:40:00 9.4 0.6 10.7 7.6 9.6 0.6 10.7 8 8.9 0.9 11.1 6.5 110 4 107 165 1.6 0 1.8 1.1 12/05/2006 00:50:00 9 0.5 10.7 7.2 9.3 0.5 11.1 8 8.6 0.7 10.7 6.5 107 3 110 165 1.6 0 1.8 1.4 12/05/2006 01:00:00 9.2 0.6 10.7 6.8 9.5 0.6 11.1 7.2 8.5 0.9 10.7 5.3 101 5 102 165 1.7 0 1.8 1.4 12/05/2006 01:10:00 9.2 0.7 10.7 6.8 9.4 0.7 11.1 7.2 8.6 0.9 10.3 5.7 101 6 104 165 1.8 0 1.8 1.4 12/05/2006 01:20:00 8.7 0.6 10.3 6.8 9 0.6 10.7 6.8 8.3 0.8 10.3 5.7 103 5 106 165 1.9 0 1.8 1.6 12/05/2006 01:30:00 8.8 0.6 10.3 6.5 9 0.6 11.1 6.8 8.2 0.9 11.5 5.7 107 5 104 165 1.9 0 2.3 1.8 12/05/2006 01:40:00 9.1 0.8 11.5 7.2 9.3 0.9 11.5 6.8 8.8 0.9 10.7 6.1 115 4 112 165 2.1 0 2.3 1.8 12/05/2006 01:50:00 8.5 0.8 10.7 6.1 8.7 0.8 11.1 6.1 8.1 1 10.7 5.7 113 4 113 165 2.1 0 2.3 1.6 12/05/2006 02:00:00 9 1.3 11.8 5.3 9.3 1.3 11.5 5.7 8.4 1.2 11.1 5.3 109 6 104 165 2.1 0 2.3 1.6 12/05/2006 02:10:00 10.1 1.2 12.2 6.1 10.4 1.2 12.6 5.7 9.6 1.1 12.2 6.5 103 5 108 165 2 0 2.3 1.8 12/05/2006 02:20:00 10.3 1.2 13 7.6 10.6 1.2 13.3 7.6 9.6 1.3 12.6 6.5 101 6 97 165 2 0 2.3 1.6 12/05/2006 02:30:00 10.5 1.2 13.3 6.5 10.7 1.3 13.7 6.5 10 1.5 13.3 6.8 103 6 105 165 2 0 2.3 1.8 12/05/2006 02:40:00 10.7 1.1 13.3 6.8 10.9 1.2 13.7 7.2 10 1.3 13 6.5 99 7 99 165 1.9 0 2.3 1.6 12/05/2006 02:50:00 10.4 1 13 7.6 10.7 1 13.3 8.4 9.8 1 12.2 7.2 106 5 106 165 1.8 0 1.8 1.6 12/05/2006 03:00:00 10.3 1 12.2 6.5 10.5 1 12.2 6.5 9.6 1.2 11.8 6.1 106 6 106 165 1.8 0 1.8 1.8 12/05/2006 03:10:00 10.2 1 12.6 7.2 10.4 1 13 7.2 9.6 1 11.8 6.8 108 5 108 165 2 0 2.3 1.8 12/05/2006 03:20:00 9.9 0.9 12.2 7.2 10.2 1 12.2 6.8 9.1 1.1 11.5 6.1 107 5 102 165 2 0 2.3 1.8 12/05/2006 03:30:00 10.5 1.2 12.6 5.7 10.7 1.3 12.6 5.7 9.9 1.3 12.6 5.7 110 5 121 165 1.9 0 2.3 1.8 12/05/2006 03:40:00 10.4 1 13 8 10.7 1 13.3 8 9.8 1.1 12.6 6.8 111 5 111 165 1.9 0 2.1 1.8 12/05/2006 03:50:00 10.4 1.3 13.3 6.8 10.6 1.3 13.3 6.8 9.8 1.3 13.3 6.8 109 6 106 165 1.9 0 2.1 1.8 12/05/2006 04:00:00 10 1.3 13.7 6.5 10.2 1.4 14.1 6.8 9.6 1.3 13 6.1 107 7 106 165 1.7 0 1.8 1.4 12/05/2006 04:10:00 10.5 0.8 12.6 8 10.7 0.8 12.2 8.4 9.6 1 11.5 6.8 112 6 108 165 1.6 0 1.8 1.4 12/05/2006 04:20:00 11 1.5 14.5 6.5 11.3 1.5 14.9 6.8 10.5 1.5 14.5 6.5 113 6 111 165 1.5 0.2 1.8 0.9 12/05/2006 04:30:00 11.4 1.5 15.3 7.2 11.6 1.6 15.6 7.6 10.9 1.7 15.6 6.8 120 8 129 165 1.3 0.1 1.6 0.9 12/05/2006 04:40:00 10.2 2.2 14.9 6.5 10.5 2.2 14.9 6.5 9.5 2.2 14.5 6.1 111 7 107 165 1.3 0.1 1.6 0.9 12/05/2006 04:50:00 12.1 1.4 14.9 8.4 12.4 1.5 15.3 8 11.5 1.7 15.3 6.8 114 6 122 165 1.4 0.1 1.6 0.9 12/05/2006 05:00:00 11.9 1.2 14.5 7.2 12.1 1.3 14.9 7.6 11.2 1.3 14.9 8 109 5 106 165 1.5 0 1.6 1.1 12/05/2006 05:10:00 12.3 1.5 15.3 7.6 12.6 1.5 16.1 8 11.7 1.5 15.3 8 111 5 110 165 1.5 0.1 1.8 0.9 12/05/2006 05:20:00 11.1 1.1 13.3 7.2 11.4 1.1 13.7 7.2 10.7 1.3 13.7 6.5 108 5 116 165 1.4 0 1.6 0.9 12/05/2006 05:30:00 11.1 1.4 14.5 7.2 11.3 1.4 14.9 7.6 10.5 1.5 14.5 6.8 109 6 104 165 1.5 0 1.6 1.4 12/05/2006 05:40:00 11.2 1.1 14.1 7.6 11.4 1.1 14.5 8 10.6 1.3 13.7 7.6 106 5 105 165 1.5 0 1.6 1.4 12/05/2006 05:50:00 12.1 1.3 15.6 8.4 12.4 1.3 15.6 8.4 11.7 1.6 14.9 7.2 109 6 101 165 1.5 0 1.8 1.4 12/05/2006 06:00:00 10.9 1.4 14.9 7.2 11.2 1.4 15.3 7.2 10.3 1.4 14.1 6.5 104 6 100 165 1.5 0 1.6 1.1 12/05/2006 06:10:00 11.4 1.5 15.3 7.2 11.6 1.5 16.1 7.2 10.7 1.5 14.1 6.8 112 6 126 165 1.5 0 1.6 1.4 12/05/2006 06:20:00 11.7 1.5 14.9 7.6 12 1.6 15.3 7.6 11.1 1.7 14.9 6.5 111 6 111 165 1.6 0 1.8 1.4 12/05/2006 06:30:00 11.8 1.7 15.6 7.2 12 1.7 16.1 7.2 11.2 2 16.1 6.8 110 7 106 165 1.6 0 1.8 1.6 12/05/2006 06:40:00 12.5 1.1 15.6 9.1 12.7 1.1 16.4 8 11.8 1.3 15.3 8 109 6 106 165 1.6 0 1.8 1.6 12/05/2006 06:50:00 12.5 1.2 14.9 9.1 12.8 1.2 14.9 9.5 12.1 1.2 14.9 8.8 108 6 112 165 1.7 0.1 1.8 1.1 12/05/2006 07:00:00 11.7 1.7 16.4 8 11.9 1.7 16.8 8 11 1.9 16.4 6.8 100 8 103 165 1.8 0 1.8 0.9 12/05/2006 07:10:00 12.7 1.3 15.6 9.1 12.9 1.3 15.6 9.5 11.9 1.5 14.9 8 101 6 102 165 1.7 0 1.8 1.1 12/05/2006 07:20:00 12.3 1.5 16.1 8.4 12.5 1.5 16.4 8 11.4 1.6 14.9 8 98 6 94 165 1.8 0.1 1.8 1.4 12/05/2006 07:30:00 12.4 1.2 14.9 8.8 12.6 1.2 15.3 8.8 11.5 1.3 14.5 8 96 7 95 165 1.8 0.1 1.8 1.4 12/05/2006 07:40:00 11.4 1.3 14.1 7.6 11.6 1.3 14.5 7.6 10.8 1.3 13.7 7.6 94 7 91 165 1.9 0.1 2.3 1.4 12/05/2006 07:50:00 12.3 1.3 15.6 8.4 12.5 1.4 15.6 8 11.2 1.5 15.6 8 100 7 83 165 2 0 2.3 1.6 12/05/2006 08:00:00 11.5 1.3 14.5 7.2 11.8 1.3 14.9 7.6 10.5 1.4 14.1 6.8 101 7 96 165 2.1 0 2.3 1.8 12/05/2006 08:10:00 11.8 1.2 14.9 8 12.1 1.2 15.3 8.8 11 1.3 14.9 7.2 95 8 101 165 2.1 0 2.3 1.8 12/05/2006 08:20:00 12.2 1.6 15.3 6.5 12.4 1.7 16.1 6.8 11.5 1.5 14.9 7.2 93 8 94 165 2.1 0 2.3 1.8 12/05/2006 08:30:00 12.6 1.6 17.9 8.8 12.9 1.6 17.2 8 11.7 1.7 16.1 6.8 100 8 116 165 2.1 0 2.3 1.8 12/05/2006 08:40:00 12.4 1.7 16.1 6.1 12.7 1.8 16.4 6.8 11.7 1.7 15.3 7.2 99 8 98 165 2.2 0 2.6 1.8 12/05/2006 08:50:00 13.2 1.4 16.8 8.8 13.5 1.4 17.9 9.5 12.4 1.6 16.8 8.8 100 7 102 165 2.1 0 2.3 1.6 12/05/2006 09:00:00 13.2 1.5 17.2 9.9 13.5 1.5 17.6 9.1 12.3 1.6 16.4 7.6 109 7 107 165 1.8 0 2.8 1.4 12/05/2006 09:10:00 13.2 1.5 16.8 8.4 13.4 1.5 17.6 8 12.4 1.6 16.1 8 107 8 89 165 1.9 0.1 2.3 1.4 12/05/2006 09:20:00 13.8 1.6 17.2 7.6 14 1.7 17.6 7.6 13 1.7 16.8 8.8 108 7 110 165 2.2 0.1 2.6 1.6 12/05/2006 09:30:00 14.1 1.5 17.6 9.9 14.4 1.5 17.9 9.9 13.3 1.7 17.2 8.8 110 7 102 165 2.2 0.1 2.6 1.8 12/05/2006 09:40:00 13.3 1.7 17.9 8.8 13.5 1.7 17.9 8.8 12.4 1.7 16.4 7.6 106 7 102 165 1.9 0.1 2.3 1.6 12/05/2006 09:50:00 13.4 2 17.6 7.6 13.7 2.1 18.3 7.2 12.5 2.1 17.6 6.1 101 6 102 165 2.3 0.1 2.6 1.8 12/05/2006 10:00:00 12.9 1.4 16.4 9.5 13.2 1.4 16.8 9.5 12.2 1.3 15.6 8.4 93 8 104 165 2.4 0.1 2.8 2.1 12/05/2006 10:10:00 12.4 1.7 16.1 7.6 12.6 1.7 17.2 8.4 11.6 1.7 15.6 7.6 92 8 91 165 2.5 0 2.8 2.3 12/05/2006 10:20:00 12 1.5 16.4 8 12.2 1.6 16.8 8 11.4 1.6 15.6 7.2 92 9 90 165 2.4 0.1 2.8 2.1 12/05/2006 10:30:00 12.3 1.7 18.3 8.8 12.6 1.7 18.3 8.8 11.8 1.6 17.6 7.2 83 8 65 165 2.5 0.1 2.8 2.1 12/05/2006 10:40:00 11.4 1.7 16.1 7.2 11.7 1.7 16.4 7.2 11 1.5 14.1 7.6 87 9 76 165 2.7 0 2.8 2.3 12/05/2006 10:50:00 11.9 1.7 16.4 8.4 12.2 1.8 17.2 8.4 11.3 1.7 15.6 7.6 90 8 98 165 2.7 0 3.3 2.6 12/05/2006 11:00:00 13.6 1.9 18.7 8.4 13.9 1.9 18.7 8.8 13 1.9 17.2 8 88 7 92 165 2.7 0 2.8 2.1 12/05/2006 11:10:00 14.4 2.1 19.1 8.8 14.7 2.1 19.5 8.4 13.7 2.1 18.7 8.4 90 9 91 165 2.6 0 2.8 2.1 12/05/2006 11:20:00 14 1.7 18.7 8.8 14.2 1.7 19.1 8.4 13.2 1.5 17.9 9.1 87 9 90 165 2.4 0.1 2.6 1.8 12/05/2006 11:30:00 13.2 1.7 17.9 9.1 13.5 1.8 17.9 9.1 12.6 1.7 17.9 8.8 82 8 88 165 2.3 0 2.6 1.8 12/05/2006 11:40:00 13.7 1.7 17.9 8.8 13.9 1.8 18.7 8.8 13 1.6 17.6 9.1 81 8 61 165 2.3 0 2.6 1.8 12/05/2006 11:50:00 14.1 1.9 19.1 9.5 14.3 2.1 19.5 9.9 13.5 2 18.7 8 81 8 78 165 2.1 0 2.6 1.8 12/05/2006 12:00:00 14.2 1.8 17.9 9.9 14.5 1.9 18.7 9.9 13.7 1.6 18.7 9.9 80 7 78 165 2.1 0 2.3 1.8 12/05/2006 12:10:00 13.2 1.7 18.3 9.1 13.4 1.7 18.3 8.8 12.8 1.7 17.2 8.4 78 9 74 165 2.1 0 2.3 1.8 12/05/2006 12:20:00 13.3 2 19.1 8.4 13.5 2.1 19.5 8 12.9 2 17.9 8 79 9 89 165 2.1 0 2.3 1.8 12/05/2006 12:30:00 15 2.4 21 8 15.2 2.5 21.4 8.4 14.6 2.3 19.5 8.8 75 10 88 165 2.1 0 2.3 1.6 12/05/2006 12:40:00 13.6 2.2 18.7 8.8 13.9 2.3 19.1 8.4 13.3 2.1 18.7 8.8 70 8 67 165 2.2 0 2.3 1.8 12/05/2006 12:50:00 13.5 1.8 19.1 8.8 13.7 2 19.1 8.4 13.1 1.8 19.5 8.4 72 9 70 165 2.3 0 2.6 1.8 12/05/2006 13:00:00 14.7 2.3 19.9 9.5 15 2.3 20.6 9.5 14.2 2.1 19.1 8 77 8 78 165 2.3 0.1 3 1.8 12/05/2006 13:10:00 15 2.1 20.6 9.5 15.3 2.2 21 9.5 14.4 2 19.9 9.1 78 8 76 165 2.3 0.1 2.6 1.8 12/05/2006 13:20:00 15 2.6 21 8.8 15.3 2.6 21.4 9.1 14.6 2.5 20.6 8.4 80 9 91 165 2.3 0.1 2.6 1.8 12/05/2006 13:30:00 13.3 2.4 19.9 8.4 13.5 2.5 20.2 8.8 12.7 2.3 19.1 8 76 9 87 165 2.3 0.2 2.6 1.8 12/05/2006 13:40:00 15.9 2.7 22.1 9.1 16.2 2.8 22.9 9.5 15.4 2.5 21.8 10.3 80 8 90 165 2.3 0.1 2.6 1.8 12/05/2006 13:50:00 14.4 2.3 21.8 9.5 14.6 2.4 21.8 9.1 14 2.4 20.2 9.5 76 9 94 165 2.4 0.1 2.6 1.8 12/05/2006 14:00:00 14.7 2.2 21 8 14.9 2.3 21 8 14.2 2.2 20.2 8 72 10 90 165 2.5 0.1 3.3 2.1 12/05/2006 14:10:00 13.9 2.1 19.9 9.5 14 2.2 19.9 9.9 13.5 2.1 20.2 8.4 73 10 85 165 2.7 0 2.8 2.3 12/05/2006 14:20:00 14.2 2.5 22.6 9.5 14.4 2.6 22.9 9.5 13.7 2.4 20.6 9.1 74 9 82 165 2.7 0 2.8 2.3 12/05/2006 14:30:00 13.5 2.5 20.2 8.4 13.8 2.6 20.6 8 13 2.4 19.9 8 78 9 75 165 2.7 0 3 2.3 12/05/2006 14:40:00 15.2 2.7 23.3 9.5 15.3 2.8 24 8.8 14.5 2.7 22.6 8 77 10 82 165 2.6 0.2 3 1.8 12/05/2006 14:50:00 14.7 2 21 10.7 15 2.2 21.4 10.7 14.4 2.1 21.8 9.9 74 10 87 165 2.5 0.1 2.8 1.8 12/05/2006 15:00:00 14.3 2.4 20.6 8.8 14.6 2.5 21 8.8 13.7 2.3 20.6 8 75 9 74 165 2.6 0.1 3.3 2.1 12/05/2006 15:10:00 15.2 2.4 22.6 9.5 15.5 2.5 23.3 9.9 14.9 2.4 21.4 9.5 79 9 84 165 2.7 0.1 3 2.3 12/05/2006 15:20:00 15.9 2.5 24 11.1 16.2 2.6 24 10.3 15.4 2.5 22.9 9.9 79 10 81 165 2.7 0 3 2.3 12/05/2006 15:30:00 15.1 2.8 22.9 9.5 15.4 2.9 23.7 9.5 14.7 2.7 22.9 8.4 77 9 81 165 2.6 0 2.8 2.1 12/05/2006 15:40:00 16.5 3.1 23.7 8.8 16.7 3.1 24 8.8 16 2.9 23.3 8.8 77 10 80 165 2.7 0 3 2.3 12/05/2006 15:50:00 15 2.7 21.8 8 15.3 2.7 22.6 8 14.4 2.6 21 8 75 10 75 165 2.8 0 3 2.3 12/05/2006 16:00:00 15.9 2.3 21 10.7 16.2 2.3 21.8 10.7 15.4 2.3 21 10.7 75 10 88 165 2.9 0 3.5 2.3 12/05/2006 16:10:00 15.5 2.3 21.8 10.3 15.7 2.4 21.8 10.3 14.9 2.2 22.6 10.3 74 9 73 165 2.9 0.2 3.3 2.3 12/05/2006 16:20:00 16.1 2.7 24 9.1 16.4 2.8 24.4 9.1 15.6 2.6 24.4 9.9 76 9 73 165 2.9 0.2 3.3 2.6 12/05/2006 16:30:00 15.6 2.6 22.9 9.9 15.8 2.7 23.7 9.5 15 2.4 22.6 9.9 75 10 83 165 2.8 0.1 3 2.3 12/05/2006 16:40:00 15.2 2.3 21.4 10.3 15.4 2.3 21.8 10.3 14.6 2.1 19.5 9.1 75 10 77 165 2.8 0 3 2.1 12/05/2006 16:50:00 16.6 2.4 24.4 11.8 16.8 2.5 24.8 11.8 16 2.5 24 10.7 78 10 75 165 2.8 0 3 2.1 12/05/2006 17:00:00 14.7 2.6 21.4 9.1 14.9 2.7 21.8 9.5 14.3 2.6 22.6 9.1 74 10 78 165 2.7 0 3.3 2.3 12/05/2006 17:10:00 17 2.2 22.1 10.7 17.4 2.3 22.9 9.9 16.3 2.3 21.8 11.1 77 9 83 165 2.7 0 3 2.3 12/05/2006 17:20:00 16.4 2.6 24 9.9 16.6 2.7 24.8 9.5 15.6 2.6 24.8 9.1 78 9 92 165 2.9 0.1 3.3 2.3 12/05/2006 17:30:00 17.3 3.2 26 10.3 17.7 3.2 26.8 10.3 16.7 2.8 25.6 10.3 84 8 91 165 2.8 0.2 3.3 2.3 12/05/2006 17:40:00 15.7 2.4 22.6 9.5 16 2.6 22.9 10.3 15.3 2.5 21.8 9.5 76 9 85 165 2.6 0 3.3 2.1 12/05/2006 17:50:00 15.8 2.9 23.7 9.9 16 3.1 24.4 9.9 15.2 2.9 24.4 9.9 74 9 83 165 2.6 0.1 2.8 2.1 12/05/2006 18:00:00 15.7 2.7 23.7 9.1 16 2.8 24 8.8 15.3 2.7 24 9.5 76 10 77 165 2.4 0.2 2.6 1.8 12/05/2006 18:10:00 14.8 2.4 19.9 9.1 14.9 2.6 20.6 8.8 14.2 2.5 20.6 8.8 71 12 69 165 2.6 0.1 2.8 2.1 12/05/2006 18:20:00 14.6 2.9 22.1 8 14.7 3.1 22.6 8.8 14.1 2.8 21.4 8.8 73 11 84 165 2.6 0 2.8 2.1 12/05/2006 18:30:00 16.7 3.2 24 9.5 17 3.3 24.4 9.1 16.2 2.9 22.9 9.5 80 9 90 165 2.6 0 2.8 2.3 12/05/2006 18:40:00 14.3 2.7 21.8 7.2 14.5 2.7 22.1 7.6 13.9 2.6 21.8 8.4 71 11 84 165 2.6 0.1 2.8 2.1 12/05/2006 18:50:00 14.9 2.6 21.8 8.8 15.1 2.6 21.8 8.8 14.4 2.4 21.4 8 69 10 54 165 2.4 0 2.8 2.1 12/05/2006 19:00:00 14.8 3.2 22.6 7.6 14.9 3.3 23.3 8 14.3 3.1 22.6 7.2 72 11 78 165 2.3 0.1 2.6 1.8 12/05/2006 19:10:00 14.1 2.1 19.1 8.4 14.2 2.2 19.5 8.4 13.7 2.2 19.1 8.4 73 11 74 165 2.4 0.1 2.8 1.8 12/05/2006 19:20:00 15.1 2.5 21.4 8.8 15.3 2.7 22.1 9.5 14.6 2.5 20.2 9.5 73 11 81 165 2.6 0 2.8 2.1 12/05/2006 19:30:00 15.1 2 21.8 10.7 15.2 2.1 22.1 11.1 14.4 1.9 20.6 10.3 75 10 85 165 2.6 0.2 2.8 1.8 12/05/2006 19:40:00 16.1 2.7 24 10.7 16.3 2.8 24.8 11.1 15.6 2.5 24.4 10.7 76 10 90 165 2.7 0.2 3 2.3 12/05/2006 19:50:00 18 2.5 23.3 12.6 18.3 2.6 24 11.8 17.1 2.6 22.9 11.5 84 7 71 165 2.7 0.2 3.3 2.3 12/05/2006 20:00:00 16.3 2.5 21.4 9.1 16.6 2.5 21.8 9.5 15.7 2.4 21.4 8.4 78 9 87 165 2.7 0 3 2.1 12/05/2006 20:10:00 16 2.7 22.6 10.3 16.3 2.7 22.9 10.3 15.6 2.6 22.1 10.3 78 8 87 165 2.4 0.1 2.8 1.8 12/05/2006 20:20:00 14.5 2.4 24 8.4 14.7 2.5 24 8.4 14.1 2.3 20.6 9.1 76 9 75 165 2.5 0 2.8 2.1 12/05/2006 20:30:00 15.6 2.3 21 9.5 15.9 2.4 21 9.1 15.2 2.2 20.6 8.8 80 8 92 165 2.5 0 2.8 2.3 12/05/2006 20:40:00 13.1 2.6 20.6 6.1 13.3 2.7 21 6.5 12.6 2.6 20.6 7.2 76 11 81 165 2.4 0.2 2.8 1.6 12/05/2006 20:50:00 14.3 2.3 20.6 7.6 14.5 2.4 21.4 7.6 13.9 2.2 19.5 7.6 74 11 78 165 2.3 0.1 2.6 1.6 12/05/2006 21:00:00 14.3 1.9 19.5 9.5 14.5 2 20.2 9.1 13.9 1.8 18.7 9.1 70 9 68 165 2.2 0.1 2.6 1.6 12/05/2006 21:10:00 15 2.1 20.6 9.9 15.2 2.2 21 9.9 14.6 2.2 19.5 8 69 9 60 165 1.9 0.1 2.3 1.4 12/05/2006 21:20:00 14.8 2 19.5 8.4 15 2.2 19.9 9.1 14.1 1.9 18.7 7.6 67 10 68 165 1.7 0 2.1 0.9 12/05/2006 21:30:00 13.2 2.1 18.3 8.8 13.4 2.3 19.1 8.8 12.9 2.1 17.9 8.4 66 11 61 165 1.7 0 1.8 1.1 12/05/2006 21:40:00 10.6 2.3 16.8 6.1 10.7 2.3 17.2 6.1 10.4 2.3 15.3 5.3 66 11 60 165 1.7 0 1.8 1.1 12/05/2006 21:50:00 9.3 1.7 15.3 5.7 9.3 1.8 16.1 5.7 9.1 1.7 15.3 4.9 57 11 70 165 1.7 0 1.8 1.4 12/05/2006 22:00:00 10.9 1.9 15.3 6.8 11.1 1.9 16.1 6.8 10.3 1.7 14.9 6.1 61 11 70 165 1.7 0 1.8 1.1 12/05/2006 22:10:00 11.1 2 17.2 6.8 11.2 2.2 17.6 6.8 10.4 2.2 17.9 6.1 58 12 84 165 1.6 0 1.8 1.1 12/05/2006 22:20:00 10.1 2 16.1 6.1 10.2 2.1 16.1 6.1 9.8 1.8 15.6 6.1 51 12 25 165 1.5 0 1.6 0.9 12/05/2006 22:30:00 10.1 1.8 16.8 5.7 10 1.9 16.8 5.7 9.7 1.8 16.4 5.3 50 11 64 165 1.4 0.1 1.6 0.9 12/05/2006 22:40:00 10.6 1.7 16.1 5.7 10.6 1.7 15.6 5.7 10.2 1.6 15.3 6.8 48 9 47 165 1.5 0.1 1.6 0.9 12/05/2006 22:50:00 11.2 2.8 17.9 5.3 11.3 2.9 18.3 5.7 10.7 2.7 17.2 5.7 50 12 52 165 1.5 0.1 1.8 0.9 12/05/2006 23:00:00 10.8 2.1 15.6 5.7 10.8 2.1 15.6 5.7 10.3 1.9 16.1 5.3 51 12 55 165 1.7 0.1 1.8 1.1 12/05/2006 23:10:00 9.5 1.8 14.1 5.3 9.5 1.9 14.1 5.3 8.9 1.7 13.7 4.9 49 11 53 165 1.7 0.1 1.8 1.4 12/05/2006 23:20:00 9.1 2.4 15.3 4.2 9.2 2.5 16.1 4.6 8.7 2.4 14.5 4.6 48 11 64 165 1.7 0.1 1.8 1.4 12/05/2006 23:30:00 9.4 1.7 14.5 5.7 9.5 1.8 14.9 4.9 9.2 1.7 14.5 5.3 49 11 69 165 1.7 0.1 1.8 1.1 12/05/2006 23:40:00 8.9 2.1 14.5 4.6 9 2.2 14.9 4.6 8.4 2 13.7 4.2 51 11 67 165 1.6 0.1 1.8 1.4 12/05/2006 23:50:00 10.6 2 16.1 6.5 10.6 2.1 16.4 6.1 10 1.9 16.1 6.1 50 10 48 165 1.5 0 1.8 1.1 12/06/2006 00:00:00 9.7 2 14.5 4.9 9.6 2.1 14.5 4.9 9.2 1.9 14.1 5.3 48 11 66 165 1.5 0 1.8 1.1 12/06/2006 00:10:00 8.3 1.3 12.6 5.3 8.2 1.3 12.2 4.9 7.5 1.3 12.2 3.8 44 10 65 165 1.5 0.1 1.8 0.9 12/06/2006 00:20:00 8.6 1.3 12.6 4.9 8.6 1.3 12.6 4.9 7.7 1.5 11.5 4.2 43 10 52 165 1.5 0.1 1.8 0.9 12/06/2006 00:30:00 8.1 1.4 13.3 5.3 8 1.4 12.6 5.3 7.1 1.4 11.8 3.8 40 10 36 165 1.3 0.2 1.6 0.9 12/06/2006 00:40:00 6.4 0.9 8.8 4.2 6.3 0.9 8.4 4.2 5.5 1 8.4 3.4 34 7 26 165 1.3 0.2 1.6 0.9 12/06/2006 00:50:00 6.8 0.7 8.8 4.9 6.6 0.7 8.4 4.6 6.1 0.8 8 4.2 30 7 32 165 1.4 0.1 1.6 0.9 12/06/2006 01:00:00 6.4 0.9 8.8 4.2 6.4 0.8 8.4 4.2 6.4 0.8 8.8 4.2 37 9 37 165 1.4 0 1.6 1.1 12/06/2006 01:10:00 5.9 0.6 8 4.6 5.8 0.6 8 4.6 5.7 0.6 8 4.6 32 4 38 165 1.4 0 1.6 1.1 12/06/2006 01:20:00 5.3 0.7 6.8 3.8 5.4 0.7 6.8 3.8 5.3 0.5 6.8 3.8 36 1 37 165 1.4 0 1.6 0.9 12/06/2006 01:30:00 3.8 0.6 5.7 2.6 4.1 0.5 5.7 3 4.2 0.5 5.7 3 41 7 35 165 1.5 0 1.8 1.4 12/06/2006 01:40:00 4.6 0.5 6.1 3.4 4.8 0.5 6.1 3.8 5 0.6 6.5 3.8 37 5 33 165 1.6 0 1.8 1.4 12/06/2006 01:50:00 4.6 0.4 5.7 3.4 4.6 0.4 5.7 3.4 4.9 0.4 6.1 3.8 30 1 30 165 1.7 0 1.8 1.4 12/06/2006 02:00:00 4.5 0.5 5.7 2.6 3.8 0.8 5.3 1.1 4.9 0.5 5.7 3 24 4 29 165 1.8 0 1.8 1.6 12/06/2006 02:10:00 4.1 0.5 5.7 3 2.2 0.6 4.2 1.1 4.5 0.5 5.7 3.4 6 5 9 165 1.8 0 1.8 1.6 12/06/2006 02:20:00 4 0.4 4.9 3 2.5 0.8 4.6 1.1 4.5 0.4 5.3 3.8 8 6 6 165 1.9 0 2.1 1.6 12/06/2006 02:30:00 4 0.6 5.7 3 3.6 0.7 5.7 1.9 4.4 0.6 6.5 3.4 18 4 19 165 1.9 0 2.1 1.8 12/06/2006 02:40:00 4.6 0.5 6.1 3.8 4.6 0.5 5.7 3.4 5.2 0.4 6.1 4.2 26 5 22 165 2 0 2.3 1.8 12/06/2006 02:50:00 4 0.4 4.9 3.4 4.1 0.4 4.9 3.4 4.5 0.5 5.7 3.4 41 5 43 165 2.1 0 2.3 1.8 12/06/2006 03:00:00 3.8 0.4 5.3 1.9 3.8 0.4 5.3 1.5 4.2 0.4 5.3 2.6 52 8 58 165 2.2 0 2.6 1.8 12/06/2006 03:10:00 3.5 0.8 5.7 1.5 3.6 1 6.1 1.1 3.6 1 6.1 0.4 81 20 60 165 2.4 0.2 2.8 1.8 12/06/2006 03:20:00 3 0.7 5.3 1.1 3 0.7 4.6 1.1 3 0.7 5.3 1.1 127 20 165 165 3 0.3 3.5 2.3 12/06/2006 03:30:00 3.7 0.7 5.3 2.3 3.5 0.8 5.3 1.9 3.7 0.6 5.3 2.6 161 9 156 165 3 0.2 3.5 2.3 12/06/2006 03:40:00 3.8 0.5 5.3 2.6 3.7 0.5 4.9 2.6 3.8 0.5 4.9 2.3 157 7 182 165 3.1 0.1 3.3 2.6 12/06/2006 03:50:00 3.9 0.4 4.9 2.6 3.8 0.4 4.9 2.6 4.1 0.4 5.3 2.6 154 7 156 165 3 0.2 3.3 2.6 12/06/2006 04:00:00 3.6 0.5 4.9 2.6 3.4 0.5 4.6 2.3 3.6 0.5 4.6 2.6 153 6 157 165 2.8 0.2 3.8 2.1 12/06/2006 04:10:00 4.1 0.6 6.1 3 4.1 0.6 5.7 3 4.2 0.6 6.1 3 158 12 165 165 2.7 0.2 3 2.1 12/06/2006 04:20:00 5.2 0.5 6.1 3.8 5 0.4 6.1 3.8 5.2 0.4 6.1 4.2 159 8 162 165 2.7 0.1 3 2.3 12/06/2006 04:30:00 5 0.7 7.2 3.8 4.8 0.7 6.8 3.4 5 0.6 6.8 3.8 158 11 158 165 2.6 0.2 2.8 2.1 12/06/2006 04:40:00 4.5 0.9 6.8 3 4.3 0.8 6.5 3 4.5 0.8 6.8 3 158 13 151 165 2.5 0.1 2.8 1.8 12/06/2006 04:50:00 4.8 0.6 6.1 3.4 4.6 0.6 6.1 3 5 0.6 6.5 3.4 163 13 172 165 2.5 0.2 2.8 1.8 12/06/2006 05:00:00 4.4 0.6 5.7 3 4.2 0.6 5.3 3 4.4 0.5 5.7 3.4 163 6 158 165 2.5 0.1 3.3 1.8 12/06/2006 05:10:00 4.9 0.6 6.1 3.4 4.7 0.6 6.1 3.4 5 0.6 6.1 3.4 162 6 159 165 2.4 0.1 2.8 1.8 12/06/2006 05:20:00 5 0.6 6.1 3.8 4.8 0.6 6.1 3.8 5.2 0.6 6.5 3.8 164 7 172 165 2.4 0 2.8 2.1 12/06/2006 05:30:00 5.7 0.6 7.2 4.2 5.5 0.5 6.8 4.2 5.7 0.5 6.8 4.2 167 14 147 165 2.4 0 2.6 2.3 12/06/2006 05:40:00 5.5 0.6 6.8 3.8 5.3 0.6 6.8 3.4 5.5 0.6 7.6 3.8 163 7 153 165 2.4 0 2.6 2.3 12/06/2006 05:50:00 5.6 0.6 7.2 4.2 5.5 0.6 6.8 4.2 5.7 0.5 7.2 4.6 158 7 161 165 2.4 0 2.6 2.3 12/06/2006 06:00:00 5.9 0.6 7.6 4.6 5.8 0.6 7.2 4.6 6 0.6 7.2 4.6 158 8 157 165 2.4 0 2.8 1.8 12/06/2006 06:10:00 6.8 0.8 8.4 4.6 6.6 0.7 8 4.6 6.7 0.6 7.6 4.9 159 8 160 165 2.4 0.1 2.8 1.8 12/06/2006 06:20:00 7 0.5 8.4 5.3 6.8 0.5 8.4 5.3 6.8 0.5 8 5.3 156 6 158 165 2.5 0 2.8 2.3 12/06/2006 06:30:00 8 0.8 9.9 5.7 7.9 0.7 9.9 6.1 7.9 0.7 9.9 6.1 153 7 153 165 2.7 0.2 3.3 2.1 12/06/2006 06:40:00 9.1 0.8 11.5 7.6 9 0.8 11.1 7.6 8.9 0.8 11.5 7.2 152 6 156 165 2.9 0.1 3.3 2.6 12/06/2006 06:50:00 9.4 1.2 12.6 6.5 9.3 1.1 12.2 6.5 9.4 1 11.5 7.2 152 8 169 165 3.2 0 3.3 2.6 12/06/2006 07:00:00 8.6 0.8 11.1 5.7 8.5 0.8 11.1 6.1 8.5 0.9 10.3 5.7 150 4 148 165 3.2 0.1 4 2.8 12/06/2006 07:10:00 8.8 0.5 9.9 7.6 8.7 0.5 10.3 7.2 8.7 0.5 9.9 7.2 149 4 145 165 3.3 0.1 3.5 2.8 12/06/2006 07:20:00 10.2 0.7 12.2 8 10.2 0.7 12.2 8 10 0.6 11.8 8 143 5 137 165 3.5 0.2 3.8 3 12/06/2006 07:30:00 9.5 0.6 11.5 8.4 9.5 0.6 11.5 8.4 9.5 0.6 11.1 7.6 147 4 151 165 3.5 0.1 3.8 3 12/06/2006 07:40:00 10.7 1 13 8 10.7 1 13.3 7.6 10.5 1 13.7 8.4 144 6 132 165 3.6 0 3.8 3.5 12/06/2006 07:50:00 10.7 1 12.6 8.4 10.6 1 12.6 8 10.5 1.1 12.6 7.2 148 5 142 165 3.7 0 4 3.5 12/06/2006 08:00:00 10 0.8 12.2 7.2 10 0.8 12.2 6.8 9.8 0.9 11.8 7.6 145 6 143 165 3.8 0 4 3.8 12/06/2006 08:10:00 11.5 1.7 15.6 7.6 11.5 1.7 15.6 7.6 11.1 1.7 14.9 6.5 142 7 137 165 4 0 4.3 3.8 12/06/2006 08:20:00 13.9 1.7 17.9 9.5 13.9 1.7 17.6 9.5 13.6 1.7 18.3 8.8 143 6 144 165 4.1 0 4.5 4 12/06/2006 08:30:00 15.1 1 17.9 11.8 15.1 1 17.6 11.8 14.8 1.2 17.6 11.1 146 5 148 165 4.2 0 4.5 3.5 12/06/2006 08:40:00 14.4 1.1 17.6 12.2 14.4 1 17.2 12.2 14 1.2 17.6 10.3 145 5 149 165 4.3 0 4.5 3.8 12/06/2006 08:50:00 14.4 1 16.8 11.5 14.4 1 17.2 11.5 14.1 1.1 16.8 11.1 145 5 135 165 4.3 0 4.5 3.5 12/06/2006 09:00:00 16 1.1 18.3 12.6 16 1.1 18.3 12.6 15.7 1.1 18.3 12.2 146 4 149 165 4.4 0 4.8 3.8 12/06/2006 09:10:00 16 1.1 18.3 13 16 1.2 18.3 12.6 15.4 1.5 18.7 11.1 144 5 142 165 4.4 0 4.5 3.8 12/06/2006 09:20:00 16.7 1 20.2 14.1 16.7 1 21 14.1 16.4 1.1 19.9 13 145 5 139 165 4.4 0 4.8 3.8 12/06/2006 09:30:00 17.2 1 20.2 14.5 17.3 1.1 20.6 14.5 16.8 1.1 19.9 13 146 5 135 165 4.4 0 4.8 3.8 12/06/2006 09:40:00 16.8 1.2 19.9 13.3 16.8 1.2 19.9 13.7 16.4 1.2 19.5 13.3 147 4 143 165 4.4 0 4.5 3.8 12/06/2006 09:50:00 16.4 1 19.5 13.7 16.4 0.9 18.7 13.7 15.9 1.1 18.3 12.2 148 4 142 165 4.3 0 4.5 3.5 12/06/2006 10:00:00 15.6 0.9 17.9 12.6 15.6 0.9 17.9 12.6 15 1.1 18.3 11.8 148 4 150 165 4.3 0 4.5 3.8 12/06/2006 10:10:00 15.2 0.9 17.6 13 15.2 1 17.6 13 14.7 1 17.6 12.6 148 3 151 165 4.3 0 4.5 3.5 12/06/2006 10:20:00 14.9 0.9 17.6 12.6 14.9 0.9 17.2 12.6 14.4 1 17.2 11.8 147 4 149 165 4.3 0.1 4.5 3.5 12/06/2006 10:30:00 14.6 0.8 16.8 12.2 14.6 0.8 16.4 11.8 14.1 0.9 16.1 11.1 147 3 151 165 4.3 0 4.5 3.8 12/06/2006 10:40:00 12.9 1.1 15.6 10.3 12.8 1.1 15.6 10.3 12.5 1.1 16.1 9.9 148 4 142 165 4.3 0 4.5 3.8 12/06/2006 10:50:00 13.1 1 15.3 10.7 13.1 1 15.6 10.7 12.8 1 14.9 10.7 146 3 145 165 4.3 0 4.5 3.8 12/06/2006 11:00:00 13 0.9 15.3 10.7 13 1 15.3 10.7 12.6 1 14.9 10.3 146 4 145 165 4.3 0 4.5 3.8 12/06/2006 11:10:00 13.1 0.7 15.3 11.5 13.1 0.7 15.3 11.1 12.7 0.9 14.5 9.5 147 4 150 165 4.3 0 4.5 3.8 12/06/2006 11:20:00 13.1 0.7 14.9 10.3 13.1 0.7 15.3 9.9 12.8 0.8 14.5 9.9 147 3 148 165 4.3 0.1 4.5 3.5 12/06/2006 11:30:00 13 0.8 14.9 10.7 13 0.8 14.9 10.7 12.8 0.9 15.3 9.5 146 5 148 165 4.3 0 4.5 3.5 12/06/2006 11:40:00 12.3 1 14.9 10.3 12.3 1 15.3 9.9 12.1 1.1 14.9 9.5 145 5 143 165 4.3 0 4.5 3.8 12/06/2006 11:50:00 13.1 0.8 15.3 11.1 13.2 0.9 15.3 11.1 13 0.8 14.9 10.3 146 4 142 165 4.3 0 4.5 3.8 12/06/2006 12:00:00 13.2 0.8 15.3 10.3 13.2 0.8 15.3 10.3 13 0.9 15.3 9.9 145 6 141 165 4.3 0 4.5 3.5 12/06/2006 12:10:00 12.8 1.2 16.1 10.3 12.8 1.2 16.1 10.3 12.5 1.2 16.1 8.8 144 6 148 165 4.3 0 4.5 4.3 12/06/2006 12:20:00 13.1 1.3 16.1 9.1 13 1.3 16.1 9.5 12.7 1.3 16.8 9.1 142 6 130 165 4.3 0 4.5 4 12/06/2006 12:30:00 12.2 1.1 14.9 8.8 12.2 1.1 14.9 9.5 11.9 1.2 14.5 7.6 142 7 147 165 4.4 0 4.5 4.3 12/06/2006 12:40:00 12.4 1.2 15.3 9.5 12.5 1.2 15.3 9.5 12.4 1.2 15.6 9.5 145 5 153 165 4.4 0 4.8 4.3 12/06/2006 12:50:00 12.5 1.3 15.6 9.1 12.6 1.3 15.6 8.8 12.1 1.5 15.3 7.2 144 8 149 165 4.4 0 4.5 4.3 12/06/2006 13:00:00 12.6 1.5 16.4 8.4 12.6 1.5 16.8 8.4 12.2 1.5 16.1 8 140 7 130 165 4.5 0 4.8 4.3 12/06/2006 13:10:00 12.5 1.3 15.3 8.4 12.5 1.3 15.6 8.8 12.1 1.2 16.1 8.8 138 7 142 165 4.6 0 4.8 4.3 12/06/2006 13:20:00 12.3 1.3 15.6 8 12.3 1.3 15.6 8.4 11.9 1.3 15.3 7.6 138 8 139 165 4.5 0 4.8 4.3 12/06/2006 13:30:00 10.7 1.3 14.9 7.6 10.8 1.3 14.1 8 10.6 1.3 14.9 7.6 140 8 140 165 4.4 0 4.8 4 12/06/2006 13:40:00 11 1.2 14.1 8 11.1 1.2 14.1 8 10.7 1.2 13.7 6.8 138 6 134 165 4.3 0 4.5 3.8 12/06/2006 13:50:00 11.5 1.3 14.5 7.6 11.5 1.3 14.9 7.6 11 1.4 14.9 7.2 135 6 129 165 4.4 0 4.5 4 12/06/2006 14:00:00 10.8 1.1 13.3 8 10.9 1 13.3 8 10.4 1 13 7.2 134 6 142 165 4.4 0 4.5 4.3 12/06/2006 14:10:00 10.2 1 13 7.2 10.3 1 13.3 7.2 9.9 1.1 13 7.2 131 6 136 165 4.4 0 4.5 4.3 12/06/2006 14:20:00 10.5 1.1 13 7.2 10.6 1 13.3 6.8 10.2 1.2 13.3 7.2 132 7 136 165 4.4 0 4.8 4.3 12/06/2006 14:30:00 12.3 1.4 16.4 7.6 12.4 1.4 16.1 8.4 12.1 1.4 15.6 9.1 133 6 139 165 4.4 0 4.8 4.3 12/06/2006 14:40:00 10.2 1.5 13.3 5.7 10.3 1.4 13.7 6.5 9.9 1.3 13.3 6.1 134 7 137 165 4.4 0 4.8 4.3 12/06/2006 14:50:00 10.2 1.2 13.3 6.8 10.3 1.2 13 6.8 10 1.2 13.7 6.8 130 7 126 165 4.4 0 4.8 3.8 12/06/2006 15:00:00 11.2 1.1 13.7 8.8 11.3 1.1 14.5 8.8 10.8 1.2 13.3 7.2 134 6 129 165 4.3 0 4.5 3.8 12/06/2006 15:10:00 11.8 1.4 14.5 8.4 11.8 1.4 14.5 8.8 11.5 1.4 14.9 8 137 6 135 165 4.2 0 4.5 3.8 12/06/2006 15:20:00 10.6 1 13 8 10.6 1 12.6 8 10.3 1.1 13 7.6 140 8 150 165 4.1 0.1 4.3 3.5 12/06/2006 15:30:00 11 1 13.3 8 11 1 13.3 8 10.8 1.1 13 7.2 139 7 136 165 4.1 0.1 4.3 3.5 12/06/2006 15:40:00 10.9 1.1 13.7 8 11 1.1 13.7 8 10.6 1.1 13.3 7.2 132 7 121 165 4 0.1 4.3 3.5 12/06/2006 15:50:00 11.3 1.3 14.1 7.6 11.4 1.3 14.1 8 11.1 1.4 14.1 6.8 128 5 127 165 4 0 4.3 3.5 12/06/2006 16:00:00 11.3 1.1 14.9 8.8 11.5 1.1 14.5 8.4 11.2 1.1 14.9 8.4 128 7 130 165 3.9 0 4.3 3.3 12/06/2006 16:10:00 10.8 1.3 13.7 7.2 10.9 1.3 13.7 7.2 10.5 1.2 13.7 6.8 130 7 121 165 3.8 0 4.3 3.3 12/06/2006 16:20:00 11.1 1.2 14.5 8.8 11.2 1.2 14.5 8.8 10.8 1.3 13.7 7.6 129 6 132 165 3.8 0 4.3 3.3 12/06/2006 16:30:00 11.7 1.3 16.1 8 11.8 1.3 16.8 8.4 11.5 1.3 16.4 8.8 130 8 119 165 3.9 0 4.3 3.3 12/06/2006 16:40:00 11.9 1.1 14.9 8.8 12 1.2 16.1 9.1 11.6 1.3 15.6 8 129 7 127 165 3.8 0 4 3.5 12/06/2006 16:50:00 10.5 1.1 13.7 7.6 10.6 1.1 14.1 7.6 10.1 1.3 13.7 5.7 130 7 142 165 3.5 0 3.8 3.5 12/06/2006 17:00:00 9.1 1 11.5 6.5 9.3 0.9 11.8 6.8 8.9 1 11.8 6.1 123 6 121 165 3.5 0 3.8 3.5 12/06/2006 17:10:00 8.6 0.9 11.1 5.7 8.8 0.9 11.5 6.5 8.4 1 10.7 5.7 120 7 128 165 3.3 0 3.5 3.3 12/06/2006 17:20:00 8.4 1 11.1 6.1 8.6 1 11.1 6.5 8.3 1.1 11.1 5.7 121 6 123 165 3.2 0 3.3 3 12/06/2006 17:30:00 8.8 0.9 11.1 5.7 8.9 1 11.8 5.3 8.5 0.9 11.5 5.7 126 7 123 165 3.2 0 3.3 3 12/06/2006 17:40:00 8.5 0.8 10.7 6.5 8.6 0.8 10.7 6.5 8.3 0.9 10.3 4.9 132 6 125 165 3.2 0 3.5 3 12/06/2006 17:50:00 8.9 0.8 11.8 6.5 8.9 0.8 11.8 6.8 8.6 1 10.7 6.1 132 8 122 165 3.3 0 3.5 3.3 12/06/2006 18:00:00 9.2 1 11.8 6.1 9.3 1 11.8 6.5 8.9 1.2 12.6 6.1 137 7 144 165 3.5 0.1 3.8 2.8 12/06/2006 18:10:00 10.6 1.1 13 8 10.6 1.1 13 8 10.3 1.2 13.3 7.2 140 7 149 165 3.7 0 3.8 3.5 12/06/2006 18:20:00 10.3 1.1 13.3 7.2 10.3 1 13.7 7.2 10.1 1 12.6 6.5 142 6 136 165 3.8 0 4 3.8 12/06/2006 18:30:00 10.9 0.8 13.3 9.1 11 0.8 13.7 9.1 10.8 0.8 13 8.4 144 5 138 165 4 0 4.3 3.8 12/06/2006 18:40:00 10.6 1 13.3 8.4 10.7 1 13.3 8.8 10.6 1 13.3 8 144 5 145 165 4.1 0 4.3 4 12/06/2006 18:50:00 10.8 1 13.3 8 10.9 1 13.7 8 10.7 1.2 13.7 7.2 142 6 136 165 4.1 0 4.3 4 12/06/2006 19:00:00 10.5 1 13 8 10.5 0.9 13 8.4 10.2 1 12.6 7.2 142 6 133 165 4.1 0.2 4.3 3.5 12/06/2006 19:10:00 10.5 1 13.3 8 10.5 1 13 7.6 10.4 1 13 7.6 143 6 145 165 4.1 0.2 4.5 3.5 12/06/2006 19:20:00 10.1 1.3 13.7 6.8 10.1 1.3 13.3 6.8 9.8 1.4 13.7 5.7 139 8 141 165 4.1 0.2 4.5 3.5 12/06/2006 19:30:00 11 0.8 13 8 11 0.8 13.3 8.4 10.8 0.9 13 8 134 6 132 165 4.1 0.2 4.5 3.5 12/06/2006 19:40:00 10.4 1 13 8 10.5 1 13.3 8.4 10.1 1.1 13 7.2 132 8 124 165 4 0.1 4.5 3.5 12/06/2006 19:50:00 10 1 13 7.2 10.1 1 13 7.6 9.9 1 12.6 7.2 130 8 122 165 4 0 4.3 3.8 12/06/2006 20:00:00 10.7 0.9 13.7 7.6 10.9 1 14.1 7.6 10.6 1 13.7 8.4 126 5 118 165 4 0 4.3 3.5 12/06/2006 20:10:00 10.8 1 13.7 8.8 11 1 13.7 9.1 10.8 0.9 13.3 8.8 128 6 129 165 4 0 4.3 3.5 12/06/2006 20:20:00 10.3 1.1 13.7 6.8 10.4 1.1 13.7 7.2 10.2 1.1 13 6.8 133 8 132 165 3.9 0 4.3 3.5 12/06/2006 20:30:00 9.7 0.9 12.2 7.2 9.7 0.9 12.2 7.2 9.5 0.9 11.8 6.8 136 8 136 165 3.8 0 4.3 3.5 12/06/2006 20:40:00 9.8 1.1 12.6 7.2 9.8 1.1 13 6.8 9.7 1.2 12.6 7.2 134 8 128 165 3.8 0 4 3.3 12/06/2006 20:50:00 9.2 1 11.8 6.8 9.4 1 12.2 7.2 9 0.9 11.5 6.8 126 9 113 165 3.7 0.1 3.8 3 12/06/2006 21:00:00 9.2 1 11.5 6.5 9.5 1.1 11.8 6.5 9 1.1 11.5 5.7 119 5 111 165 3.6 0.1 3.8 3.3 12/06/2006 21:10:00 9.2 0.7 11.8 7.2 9.4 0.8 11.8 7.2 8.8 0.8 11.1 6.1 116 6 117 165 3.5 0 3.8 3.5 12/06/2006 21:20:00 9 0.8 10.7 6.5 9.2 0.8 11.1 6.1 8.8 0.9 11.1 5.3 120 7 116 165 3.3 0 3.8 3.3 12/06/2006 21:30:00 9.8 0.9 12.2 7.6 10.1 0.8 12.2 7.6 9.4 1.1 12.2 6.1 115 5 106 165 3.4 0 3.5 3.3 12/06/2006 21:40:00 10.3 0.8 12.6 8 10.5 0.8 13 8.8 9.8 0.9 12.2 7.2 119 5 121 165 3.4 0 3.5 3.3 12/06/2006 21:50:00 9.8 0.7 11.5 6.8 10 0.7 11.8 7.6 9.4 0.9 11.5 7.2 115 6 124 165 3.4 0 3.5 3.3 12/06/2006 22:00:00 9 0.8 11.5 6.8 9.2 0.8 11.8 7.2 8.6 0.8 11.5 6.5 112 7 106 165 3.4 0 3.8 3.3 12/06/2006 22:10:00 9.7 1 11.8 5.7 10 1 12.2 5.3 9.4 1.2 11.8 6.5 105 6 106 165 3.5 0 3.5 3.3 12/06/2006 22:20:00 9.9 0.7 12.2 6.8 10.2 0.7 11.8 7.2 9.3 1 11.8 6.1 99 5 90 165 3.5 0.1 3.8 3 12/06/2006 22:30:00 10.1 1 12.6 6.5 10.3 1 13 6.8 9.5 1.1 12.2 5.7 101 6 102 165 3.5 0.1 3.8 3.3 12/06/2006 22:40:00 10.3 1 13 6.5 10.6 1 13 7.2 9.3 1.1 12.6 6.1 102 6 97 165 3.5 0.1 3.8 3.3 12/06/2006 22:50:00 10.6 1 12.6 7.2 10.8 1 13 7.2 9.8 1.1 12.6 6.5 99 6 92 165 3.6 0 3.8 3.3 12/06/2006 23:00:00 10.1 1.2 12.6 6.8 10.3 1.2 13 7.2 9.3 1.2 12.2 6.5 96 7 94 165 3.7 0 3.8 3.5 12/06/2006 23:10:00 10.1 0.9 12.2 7.2 10.3 0.9 12.2 7.6 9.4 0.9 12.2 6.5 94 6 95 165 3.8 0 4 3.8 12/06/2006 23:20:00 10.3 1.1 12.6 7.2 10.6 1.1 13 7.2 9.8 1.1 12.6 6.5 92 6 99 165 3.9 0 4.3 3.8 12/06/2006 23:30:00 11.1 1 13.3 8 11.3 1 13.7 8 10.4 1 13 7.6 91 6 84 165 3.8 0 4.3 3.3 12/06/2006 23:40:00 11.1 0.8 13 8.8 11.4 0.8 13.3 8.8 10.6 1 13 7.2 90 5 95 165 3.8 0 4 3.3 12/06/2006 23:50:00 11 0.9 13.7 8.4 11.3 0.9 13.7 8.8 10.3 1 12.6 7.2 90 4 91 165 3.8 0 4.3 3.3 12/07/2006 00:00:00 11.1 0.8 12.6 8.4 11.4 0.9 13 8 10.5 0.9 12.6 7.6 88 5 93 165 3.8 0 4.3 3.3 12/07/2006 00:10:00 10.4 1 12.6 7.6 10.7 1 12.6 8 9.9 1.1 11.8 6.5 86 6 100 165 3.8 0.2 4.3 3.3 12/07/2006 00:20:00 10.5 1.2 13.3 6.8 10.8 1.2 13.7 7.2 10 1.1 13 6.8 83 6 81 165 3.8 0.1 4.3 3.3 12/07/2006 00:30:00 11.1 1 13 8.8 11.4 1 13.3 8.4 10.6 1 13 8 81 5 81 165 3.8 0.1 4.3 3.3 12/07/2006 00:40:00 11.3 0.7 13 9.1 11.6 0.7 13.3 9.1 10.7 0.8 12.6 8.4 82 4 82 165 3.8 0.2 4.3 3.5 12/07/2006 00:50:00 10.5 1.3 12.6 6.8 10.8 1.3 13 6.8 10.1 1.4 12.6 6.5 78 6 73 165 3.8 0.1 4 3.3 12/07/2006 01:00:00 9.9 1 12.2 7.6 10.2 1 12.6 7.2 9.4 1 11.5 6.5 78 6 84 165 3.8 0.1 4.3 3.3 12/07/2006 01:10:00 10.8 1.1 13 7.2 11.1 1.1 13.3 7.6 10.4 1.2 13.3 6.8 79 6 80 165 3.8 0.2 4.3 3.5 12/07/2006 01:20:00 10.4 1.2 13.3 7.2 10.7 1.2 13.7 7.6 10.1 1.1 13 7.6 79 7 84 165 3.9 0.2 4.3 3.5 12/07/2006 01:30:00 9.9 1.2 12.6 6.1 10.1 1.2 13 6.5 9.6 1.2 12.6 6.1 79 8 84 165 3.9 0.2 4.3 3.5 12/07/2006 01:40:00 10.1 1.3 13.3 6.5 10.3 1.4 13.7 6.5 9.8 1.4 13.3 6.1 79 7 87 165 3.9 0.1 4.3 3.5 12/07/2006 01:50:00 10.5 1.5 14.5 6.5 10.7 1.6 14.9 6.8 10.1 1.5 14.5 6.5 79 8 87 165 3.9 0 4.3 3.5 12/07/2006 02:00:00 9.3 1.3 13.7 5.3 9.5 1.5 13.7 5.3 9 1.3 12.6 5.7 76 9 70 165 3.9 0 4.3 3.8 12/07/2006 02:10:00 8.3 1.3 11.8 5.3 8.4 1.3 11.8 5.7 8.1 1.2 11.8 5.7 75 11 86 165 3.8 0 4.3 3.5 12/07/2006 02:20:00 9.3 1.6 13.7 5.3 9.4 1.6 14.1 5.7 9.1 1.5 13.7 5.7 73 11 85 165 3.6 0 3.8 3.3 12/07/2006 02:30:00 10.5 1.4 14.1 6.8 10.7 1.5 14.5 6.8 10.2 1.3 13.7 7.2 75 7 85 165 3.4 0.2 3.8 2.8 12/07/2006 02:40:00 8.4 1.4 12.2 5.7 8.4 1.5 12.2 5.3 8.2 1.5 12.2 4.9 52 13 67 165 3 0 3.3 2.8 12/07/2006 02:50:00 7.8 1.1 11.1 5.3 7.8 1.2 10.7 4.9 7.6 1.1 10.7 5.3 39 7 43 165 3.1 0 3.3 2.8 12/07/2006 03:00:00 7.6 0.9 9.9 4.9 7.6 0.9 9.9 4.9 7.2 0.9 9.5 4.6 41 7 25 165 3.3 0.1 3.5 2.8 12/07/2006 03:10:00 7.3 1.2 11.1 4.2 7.3 1.2 11.1 4.2 7 1.1 10.7 4.2 41 8 46 165 3.6 0 3.8 3.5 12/07/2006 03:20:00 7.2 1.2 10.7 3.4 7.3 1.2 10.7 3.8 6.9 1.2 9.5 3.8 55 10 54 165 3.8 0 4 3.3 12/07/2006 03:30:00 7.5 1.5 12.2 4.2 7.6 1.6 12.2 4.2 7.2 1.4 11.1 3.8 59 11 69 165 3.8 0.2 4.3 3.3 12/07/2006 03:40:00 6.7 1.5 11.8 3.8 6.7 1.6 11.5 3.8 6.4 1.5 11.5 3 50 11 59 165 3.8 0.1 4.3 3.5 12/07/2006 03:50:00 6 1.1 9.9 3.8 5.9 1.1 9.9 3.4 5.7 0.9 9.1 3.8 45 12 52 165 3.9 0 4 3.5 12/07/2006 04:00:00 6.7 1 9.1 3 6.6 1.1 9.5 3.4 6.5 1.1 9.1 3.8 39 9 51 165 3.9 0.1 4.3 3.5 12/07/2006 04:10:00 6.5 1.4 10.3 3.8 6.5 1.5 10.3 3.4 6.2 1.3 9.9 3.4 61 13 79 165 4 0.2 4.3 3.5 12/07/2006 04:20:00 7.9 1.2 10.7 5.3 8 1.2 11.1 5.7 7.6 1.2 10.7 4.9 73 8 77 165 4 0.1 4.3 3.5 12/07/2006 04:30:00 6.3 1 9.5 4.2 6.3 1 9.9 4.2 6.2 1 9.5 4.6 66 9 70 165 3.9 0.1 4.3 3.5 12/07/2006 04:40:00 6.8 1.1 9.9 4.2 6.8 1.2 10.3 3.8 6.6 1.1 9.9 4.2 64 10 64 165 3.8 0.1 4.3 3.3 12/07/2006 04:50:00 7.2 1.1 9.9 4.6 7.2 1.2 9.9 4.2 6.9 1.1 9.1 4.2 53 10 43 165 3.3 0.1 3.8 2.8 12/07/2006 05:00:00 5.1 0.9 8 3 5.1 1 8.8 2.6 5 0.9 8 3 58 17 81 165 3.6 0 3.8 3 12/07/2006 05:10:00 6.3 0.9 7.6 3.8 6.4 0.9 8 3.8 6.1 1 8 3.4 106 11 90 165 3.6 0.2 3.8 3 12/07/2006 05:20:00 6.3 0.8 8.4 4.2 6.3 0.8 8.8 4.2 6 0.9 8.4 3.8 117 8 108 165 3.5 0 3.8 3.3 12/07/2006 05:30:00 6 0.6 7.2 4.2 6.1 0.6 7.2 4.2 5.9 0.7 7.6 3.8 114 6 119 165 3.5 0 3.5 3 12/07/2006 05:40:00 4.8 0.5 6.5 3.8 4.9 0.5 6.5 3.8 4.7 0.6 6.5 3 105 5 102 165 3.4 0 3.5 3 12/07/2006 05:50:00 4.6 0.7 6.5 3 4.8 0.7 6.5 3 4.3 0.7 5.7 3 93 7 88 165 3.5 0 3.8 3.3 12/07/2006 06:00:00 7.2 1.4 10.3 4.2 7.4 1.5 10.3 4.6 6.9 1.5 10.3 4.2 88 7 104 165 3.7 0.2 4.3 3 12/07/2006 06:10:00 8.7 1.1 11.1 4.9 8.9 1.1 11.8 4.6 8.1 1.1 11.1 5.3 97 8 104 165 4 0.1 4.3 3.5 12/07/2006 06:20:00 9.3 0.8 11.1 6.5 9.5 0.8 11.5 6.5 8.7 0.9 11.1 5.7 102 6 101 165 4 0.1 4.3 3.8 12/07/2006 06:30:00 10.1 1.1 12.6 6.1 10.3 1.1 13 6.1 9.7 1.1 12.2 6.5 106 7 87 165 4 0.1 4.5 3.5 12/07/2006 06:40:00 8.7 1.2 11.8 5.7 8.8 1.3 11.8 5.3 8.3 1.4 11.8 4.9 112 9 112 165 4 0.2 4.3 3.5 12/07/2006 06:50:00 9.2 1 11.8 5.3 9.3 1.1 11.8 5.7 8.7 1.1 11.5 6.1 116 7 121 165 4 0.2 4.3 3.5 12/07/2006 07:00:00 8.9 1 11.5 5.7 9 1 11.5 5.3 8.4 1 11.5 5.3 117 7 114 165 3.9 0.2 4.3 3.5 12/07/2006 07:10:00 7.5 1.3 9.9 4.9 7.6 1.4 10.3 4.9 7.2 1.4 10.7 4.6 124 8 117 165 3.9 0.2 4.3 3.5 12/07/2006 07:20:00 7.4 0.8 9.1 4.9 7.4 0.8 9.5 4.9 6.9 0.9 9.1 4.6 118 7 125 165 3.9 0.2 4.3 3.5 12/07/2006 07:30:00 7.7 0.9 9.9 4.9 7.8 0.9 10.3 4.9 7.5 0.9 9.5 4.6 118 6 114 165 3.9 0.2 4.3 3.5 12/07/2006 07:40:00 7.3 0.6 8.8 5.7 7.4 0.6 8.8 5.7 7.2 0.7 8.8 5.3 120 6 128 165 3.9 0.2 4.3 3.5 12/07/2006 07:50:00 6.3 0.6 8 4.6 6.3 0.7 8 4.6 6.3 0.6 8 4.2 124 6 123 165 3.8 0.2 4.3 3.5 12/07/2006 08:00:00 6.3 0.6 7.6 4.9 6.3 0.6 7.6 4.9 6.3 0.6 7.6 4.9 132 5 128 165 3.8 0.2 4.3 3.5 12/07/2006 08:10:00 5 0.5 6.1 3.4 4.9 0.5 6.1 3.4 5 0.5 6.5 3.4 137 8 136 165 3.8 0 4.3 3.5 12/07/2006 08:20:00 4.4 0.4 5.3 3.4 4.3 0.4 4.9 3.4 4.3 0.4 5.3 2.6 138 3 136 165 3.8 0 4 3.5 12/07/2006 08:30:00 3.6 0.5 4.6 2.3 3.6 0.5 4.6 2.3 3.7 0.5 4.9 2.3 131 7 122 165 3.8 0 4 3.8 12/07/2006 08:40:00 2.2 0.5 3.4 1.1 2.1 0.6 3.4 0.4 2.3 0.6 3.4 0.7 141 13 130 165 3.8 0 4 3.5 12/07/2006 08:50:00 1.7 0.4 2.6 0.7 1.6 0.4 2.6 0.4 1.8 0.4 2.6 0.7 150 4 150 165 3.6 0.2 3.8 3.3 12/07/2006 09:00:00 1.7 0.3 2.6 1.1 1.6 0.3 2.3 1.1 1.9 0.3 2.6 1.1 131 10 142 165 3.6 0.2 3.8 3 12/07/2006 09:10:00 1 0.5 1.9 0.4 0.8 0.4 1.9 0.4 1.2 0.4 1.9 0.4 133 15 144 165 3.6 0.2 3.8 3 12/07/2006 09:20:00 1.6 0.2 2.3 1.1 1.5 0.2 2.3 1.1 1.7 0.2 2.3 1.1 138 13 162 165 3.5 0.3 4 2.8 12/07/2006 09:30:00 0.6 0.3 1.5 0.4 0.4 0.2 1.1 0.4 0.7 0.5 1.9 0.4 137 7 123 165 3.6 0.1 3.8 3.3 12/07/2006 09:40:00 0.5 0.2 1.1 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 142 3 145 165 3.6 0.1 3.8 3 12/07/2006 09:50:00 0.4 0 0.4 0.4 0.4 0 0.7 0.4 0.4 0 0.4 0.4 141 3 165 165 3.7 0.1 3.8 3.3 12/07/2006 10:00:00 0.7 0.3 1.5 0.4 0.4 0.1 0.7 0.4 0.4 0 0.4 0.4 154 3 161 165 3.6 0.2 3.8 3 12/07/2006 10:10:00 0.9 0.5 2.3 0.4 0.6 0.4 1.9 0.4 0.6 0.4 1.9 0.4 162 3 162 165 3.5 0.1 3.8 3.3 12/07/2006 10:20:00 0.9 0.5 2.3 0.4 0.6 0.4 1.9 0.4 0.6 0.4 1.9 0.4 182 12 203 165 3.5 0.1 4 3 12/07/2006 10:30:00 0.4 0.2 1.1 0.4 0.4 0 0.4 0.4 0.4 0.1 1.1 0.4 202 1 202 165 3.5 0.2 3.8 2.8 12/07/2006 10:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 199 1 165 165 3.5 0.1 3.8 3 12/07/2006 10:50:00 1 0.3 1.5 0.4 0.4 0.1 1.1 0.4 0.6 0.4 1.5 0.4 187 4 195 165 3.5 0.2 3.8 2.8 12/07/2006 11:00:00 0.9 0.5 1.9 0.4 0.4 0.2 1.5 0.4 0.6 0.5 1.9 0.4 182 2 180 165 3.6 0.1 3.8 3 12/07/2006 11:10:00 0.9 0.4 1.9 0.4 0.6 0.3 1.1 0.4 0.8 0.5 1.5 0.4 186 3 178 165 3.6 0 3.8 3.5 12/07/2006 11:20:00 0.8 0.3 1.5 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 187 1 185 165 3.5 0.2 3.8 2.8 12/07/2006 11:30:00 1.4 0.3 1.9 0.7 1 0.4 1.5 0.4 1 0.4 1.9 0.4 187 1 187 165 3.5 0.2 3.8 3 12/07/2006 11:40:00 0.8 0.4 1.9 0.4 0.5 0.3 1.5 0.4 0.4 0.2 1.5 0.4 189 6 186 165 3.6 0.2 4 3.3 12/07/2006 11:50:00 0.8 0.3 1.5 0.4 0.6 0.3 1.1 0.4 0.7 0.4 1.5 0.4 194 5 199 165 3.8 0 4.3 3.5 12/07/2006 12:00:00 1.2 0.4 1.9 0.4 0.8 0.4 1.5 0.4 0.9 0.5 1.9 0.4 178 9 184 165 4.1 0.1 4.5 3.5 12/07/2006 12:10:00 1.8 0.6 3.4 0.7 1.5 0.7 3.4 0.4 1.7 0.6 3.4 0.4 167 8 164 165 4.7 0.1 5 4.3 12/07/2006 12:20:00 2.8 0.6 4.2 1.5 2.5 0.6 3.8 1.5 2.9 0.5 4.2 1.5 169 7 165 165 4.6 0.2 5 4.3 12/07/2006 12:30:00 2.8 0.4 3.8 1.5 2.6 0.4 3.8 1.5 2.8 0.4 3.8 1.9 175 4 174 165 4 0 4.5 3.8 12/07/2006 12:40:00 2.7 0.2 3 1.9 2.5 0.2 3 1.9 2.8 0.2 3.4 2.3 173 7 178 165 4 0 4.5 3.8 12/07/2006 12:50:00 2.6 0.2 3 2.3 2.4 0.2 2.6 1.9 2.7 0.2 3.4 2.3 164 4 170 165 4 0 4.3 3.8 12/07/2006 13:00:00 2.5 0.3 3 1.5 2.4 0.3 3 1.5 2.7 0.2 3.4 1.9 161 3 161 165 3.8 0 4.3 3.8 12/07/2006 13:10:00 2.9 0.5 3.8 1.5 2.8 0.5 3.8 1.9 3.2 0.5 4.2 1.9 166 11 161 165 4.1 0.1 4.5 3.8 12/07/2006 13:20:00 2.2 0.7 3.8 0.4 2 0.7 3.8 0.4 2.3 0.7 4.2 0.7 160 11 168 165 4.7 0.1 5 4.3 12/07/2006 13:30:00 1.9 0.4 3 0.7 1.8 0.4 2.6 0.7 2 0.5 3.4 0.7 159 14 145 165 5 0 5.5 4.8 12/07/2006 13:40:00 2.6 0.9 4.6 1.1 2.6 0.8 4.6 0.7 2.9 0.9 4.6 1.1 155 14 157 165 5.2 0.1 6 4.8 12/07/2006 13:50:00 2.6 0.3 3.4 1.5 2.6 0.3 3.4 1.5 3 0.3 3.8 2.3 160 5 177 165 4.8 0.1 5.5 4.5 12/07/2006 14:00:00 1.9 0.4 3 0.7 1.8 0.6 3 0.7 2.3 0.5 3.4 1.1 150 13 160 165 4.8 0 5 4.5 12/07/2006 14:10:00 1.8 0.5 3.4 0.4 1.4 0.5 3 0.4 2 0.5 3.4 1.1 150 12 159 165 5 0 5.2 4.8 12/07/2006 14:20:00 2.2 0.4 3.4 1.1 1.9 0.5 3 1.1 2.5 0.3 3.4 1.9 143 7 141 165 4.8 0.3 5.2 4.3 12/07/2006 14:30:00 3 0.4 3.8 1.9 2.7 0.4 3.8 1.5 3.1 0.3 4.2 2.3 147 11 133 165 4 0 4.5 3.5 12/07/2006 14:40:00 3.6 0.4 4.9 2.6 3.3 0.4 4.6 2.3 3.7 0.4 4.9 2.6 152 8 155 165 3.8 0 4 3.5 12/07/2006 14:50:00 2.9 0.3 3.8 1.9 2.7 0.3 3.4 1.9 3.1 0.4 3.8 2.3 153 8 153 165 3.8 0 4 3.5 12/07/2006 15:00:00 2.6 0.6 4.2 1.1 2.3 0.6 3.8 0.4 2.7 0.5 4.2 1.1 157 10 159 165 3.7 0 4 3.5 12/07/2006 15:10:00 2.1 0.5 3 0.7 1.8 0.6 3 0.4 2.3 0.5 3.4 1.1 143 14 126 165 3.6 0 3.8 3.5 12/07/2006 15:20:00 1.5 0.5 2.3 0.4 1.2 0.5 2.3 0.4 1.5 0.7 2.6 0.4 177 9 165 165 3.5 0 3.8 3.3 12/07/2006 15:30:00 1.1 0.4 2.3 0.4 0.9 0.4 1.9 0.4 1.1 0.6 2.6 0.4 172 13 189 165 3.6 0 4 3.5 12/07/2006 15:40:00 1.6 0.5 2.6 0.4 1.5 0.6 3 0.4 1.8 0.7 3 0.4 160 20 188 165 3.5 0 3.8 3.3 12/07/2006 15:50:00 2.3 0.6 3.8 0.7 2.1 0.6 3.8 0.4 2.4 0.4 3.4 1.1 146 11 152 165 3.2 0.1 3.5 2.8 12/07/2006 16:00:00 2.8 0.4 3.8 1.9 2.5 0.4 3.4 1.1 2.7 0.4 3.4 1.1 160 13 141 165 3 0 3.3 2.8 12/07/2006 16:10:00 3.1 0.3 4.2 2.3 2.8 0.3 3.4 1.9 3 0.3 3.8 2.3 160 8 168 165 2.9 0 3.5 2.6 12/07/2006 16:20:00 3.9 0.3 4.6 3 3.6 0.3 4.2 3 3.9 0.3 4.6 3 160 7 162 165 2.8 0 3 2.6 12/07/2006 16:30:00 3.4 0.5 4.9 2.3 3.2 0.5 4.6 1.9 3.4 0.6 5.3 2.6 177 11 158 165 2.9 0 3.3 2.8 12/07/2006 16:40:00 3.5 0.6 4.6 2.3 3.4 0.6 4.6 1.9 3.4 0.5 4.6 2.3 210 10 211 165 2.9 0 3.3 2.6 12/07/2006 16:50:00 3.2 0.8 4.6 0.4 3.1 0.9 4.2 0.4 2.9 0.8 4.6 0.4 241 23 245 165 2.6 0.1 2.8 2.3 12/07/2006 17:00:00 2.5 0.7 4.2 0.4 2.4 0.7 4.2 0.7 2.5 0.6 3.8 0.4 203 24 238 165 2.5 0.1 2.8 2.1 12/07/2006 17:10:00 3.3 1.1 6.1 1.5 3.2 1.1 6.1 1.5 3.2 1 6.1 1.9 196 12 210 165 2.5 0 2.8 2.3 12/07/2006 17:20:00 5.8 0.4 6.8 4.6 5.8 0.4 6.8 4.6 6 0.6 7.2 4.6 195 7 201 165 2.5 0 2.8 2.3 12/07/2006 17:30:00 4.5 0.9 6.5 2.6 4.3 1 6.1 2.3 4.8 1 6.5 3 178 6 187 165 2.6 0 2.8 2.6 12/07/2006 17:40:00 3.2 0.7 4.6 1.9 2.9 0.7 4.6 1.5 3.3 0.7 4.6 1.9 176 3 178 165 2.4 0 2.8 2.3 12/07/2006 17:50:00 4.2 0.5 5.3 2.6 3.9 0.5 4.9 2.3 4.2 0.5 5.3 3 175 6 179 165 2.4 0 2.6 2.1 12/07/2006 18:00:00 3.9 0.6 6.1 2.3 3.7 0.6 6.1 1.9 3.8 0.6 5.7 2.6 172 9 194 165 2.3 0 2.6 2.1 12/07/2006 18:10:00 5.9 0.8 8.4 3.4 5.7 0.8 8.4 3.4 5.8 1 8.8 3 179 10 187 165 2.3 0 2.6 2.1 12/07/2006 18:20:00 5.2 0.5 6.8 3.8 5.1 0.5 7.2 3.8 5.2 0.5 7.2 3.8 189 6 198 165 2.2 0 2.3 1.8 12/07/2006 18:30:00 6.2 0.8 8 4.2 6.2 0.8 8 4.2 6.4 0.8 8 4.2 196 6 189 165 2.3 0.1 2.6 1.6 12/07/2006 18:40:00 5.2 1 8 3.4 5.1 1 8 3.4 5.3 1.1 8.4 3.4 187 6 196 165 2.4 0 2.6 2.1 12/07/2006 18:50:00 4.3 0.6 6.1 2.6 4.3 0.6 6.1 3 4.4 0.6 6.1 3 184 6 186 165 2.3 0.1 2.6 1.8 12/07/2006 19:00:00 5.2 0.7 6.8 3.8 5.2 0.7 6.5 3.8 5.3 0.7 6.8 3.4 182 6 188 165 2.2 0 2.6 1.8 12/07/2006 19:10:00 4.9 0.4 5.7 4.2 4.9 0.4 5.7 3.8 5.2 0.4 6.1 4.2 187 3 187 165 2.3 0 2.6 1.8 12/07/2006 19:20:00 5 0.4 6.1 3.8 4.9 0.4 6.1 3.8 5 0.4 6.1 4.2 172 6 165 165 2.4 0.1 2.6 1.8 12/07/2006 19:30:00 5.7 0.4 6.5 4.6 5.5 0.4 6.5 4.6 5.8 0.4 6.8 4.6 173 5 173 165 2.4 0 2.6 1.8 12/07/2006 19:40:00 5.1 0.5 6.1 3.4 4.8 0.5 5.7 3 4.9 0.6 6.1 3 176 7 181 165 2.4 0 2.6 2.3 12/07/2006 19:50:00 6 0.8 8.4 3.8 5.8 0.8 8.4 3.4 5.9 0.8 9.1 3 179 11 192 165 2.4 0 2.6 2.3 12/07/2006 20:00:00 6.7 0.7 8.8 5.3 6.4 0.6 8.4 4.9 6.7 0.6 8.4 4.9 172 12 165 165 2.3 0 2.6 1.8 12/07/2006 20:10:00 6.7 0.6 8.8 4.9 6.3 0.6 8 4.9 6.6 0.7 8.4 5.3 174 5 189 165 2.3 0 2.6 2.1 12/07/2006 20:20:00 6.1 0.6 7.2 4.2 5.7 0.5 6.8 4.2 6.1 0.6 7.6 4.2 172 5 174 165 2.4 0 2.6 2.1 12/07/2006 20:30:00 6.8 0.8 8.8 5.3 6.4 0.7 8.4 4.9 6.8 0.7 8.4 4.9 166 7 171 165 2.3 0 2.6 1.8 12/07/2006 20:40:00 9.3 1.2 11.8 6.5 9 1.1 11.8 6.5 9.3 1.2 12.6 5.7 166 7 139 165 2.1 0 2.3 1.8 12/07/2006 20:50:00 9 1.2 11.8 6.8 8.7 1.1 11.5 6.5 9.2 1.2 12.2 7.2 173 5 165 165 2.1 0 2.3 1.8 12/07/2006 21:00:00 9.9 1.2 13.7 7.2 9.7 1.1 13.3 6.8 9.8 1.2 13 7.6 165 12 171 165 2.1 0 2.6 1.8 12/07/2006 21:10:00 12.8 1 15.3 9.5 12.5 0.9 14.9 9.5 13 1.1 15.6 9.9 168 14 170 165 2.1 0 2.3 1.8 12/07/2006 21:20:00 13.3 0.8 15.6 10.7 13 0.8 15.3 10.3 13.4 0.9 15.3 11.1 165 8 171 165 2.1 0 2.3 1.8 12/07/2006 21:30:00 14.3 0.7 16.1 12.2 13.9 0.6 16.1 11.8 14.4 0.9 16.8 11.5 165 18 165 165 2.1 0 2.3 1.8 12/07/2006 21:40:00 12.8 1.1 15.3 10.7 12.3 1 14.5 10.3 13.1 1 15.6 10.3 169 6 171 165 2.1 0 2.3 1.6 12/07/2006 21:50:00 11.2 1.1 13.3 8.8 10.8 1 13 8.8 11.4 1.1 14.1 8.8 168 9 171 165 2.1 0 2.3 1.6 12/07/2006 22:00:00 8.7 0.8 11.1 6.5 8.5 0.8 10.7 6.5 9 0.9 11.5 6.8 166 8 165 165 2.1 0 2.3 1.8 12/07/2006 22:10:00 7.8 0.6 8.8 6.1 7.7 0.6 8.8 6.1 8 0.6 9.5 6.5 155 5 149 165 2.1 0 2.6 1.8 12/07/2006 22:20:00 10 1.2 13 8 9.9 1.2 12.2 8 10 1.3 12.6 7.2 154 5 159 165 2.1 0 2.3 1.8 12/07/2006 22:30:00 11.4 0.7 13 9.5 11.4 0.6 13 9.5 11.6 0.7 13.7 9.1 151 3 149 165 2 0 2.3 1.8 12/07/2006 22:40:00 10.9 0.6 12.6 9.5 11 0.7 12.6 9.5 10.8 0.8 13 8.4 148 5 141 165 2 0 2.3 1.8 12/07/2006 22:50:00 11.7 1.3 15.3 9.1 11.7 1.3 15.6 8.8 11.5 1.4 15.3 8 145 5 146 165 2.2 0 2.6 1.8 12/07/2006 23:00:00 13.5 0.9 15.3 10.7 13.5 0.9 15.3 10.7 13.3 1.1 15.6 9.5 148 4 150 165 2.3 0 2.3 2.1 12/07/2006 23:10:00 14.5 1.1 16.8 11.5 14.5 1.2 16.8 11.5 14.3 1.3 17.6 10.7 146 5 141 165 2.3 0 2.6 1.8 12/07/2006 23:20:00 15.3 1.4 18.7 12.2 15.3 1.5 18.7 11.8 14.9 1.7 18.7 10.7 145 5 145 165 2.4 0 2.8 2.3 12/07/2006 23:30:00 15.9 0.9 17.9 13.3 15.9 0.9 17.9 13.3 15.7 1.1 17.9 12.6 147 5 136 165 2.6 0 2.8 2.3 12/07/2006 23:40:00 15.6 1 17.6 13 15.6 1 17.6 13 15.5 1.2 17.9 10.7 148 4 148 165 2.5 0 2.8 2.3 12/07/2006 23:50:00 15.8 1.1 18.7 12.2 15.8 1.1 18.7 12.6 15.4 1.3 18.3 11.5 148 5 145 165 2.4 0 2.6 2.3 12/08/2006 00:00:00 16.2 1.1 19.9 13 16.2 1.1 19.9 13 15.9 1.3 19.5 10.7 147 6 145 165 2.4 0 2.6 2.3 12/08/2006 00:10:00 15.9 1.5 20.6 13 15.9 1.5 20.6 13 15.7 1.6 19.9 11.1 149 5 149 165 2.4 0 2.6 2.3 12/08/2006 00:20:00 16.6 2 21 12.2 16.6 2.1 21 12.6 16.1 2.1 20.6 11.5 145 6 134 165 2.5 0 2.8 2.3 12/08/2006 00:30:00 17.1 1.8 21 12.2 17 1.8 20.6 12.2 16.8 2 20.6 10.3 145 6 142 165 2.6 0 2.8 2.3 12/08/2006 00:40:00 18.3 1.2 21 14.9 18.4 1.3 21.4 14.9 18 1.6 21.4 13.7 145 5 135 165 2.7 0 2.8 2.6 12/08/2006 00:50:00 17.3 1.5 21.4 14.1 17.4 1.5 21.4 14.1 17 1.7 21.8 12.2 143 6 147 165 2.9 0 3.3 2.6 12/08/2006 01:00:00 17.8 1.7 22.1 13.7 17.9 1.7 22.6 13.3 17.5 1.9 21.4 12.6 141 7 142 165 3.2 0 3.5 3 12/08/2006 01:10:00 19.1 1.8 23.7 14.9 19.1 1.8 23.7 14.9 18.7 2 23.3 13.7 144 6 139 165 3.4 0 3.5 3.3 12/08/2006 01:20:00 18.6 1.6 22.1 13 18.6 1.6 21.8 13.3 18.2 1.9 22.1 12.6 149 6 148 165 3.3 0.2 3.5 2.6 12/08/2006 01:30:00 17.7 1.2 20.2 13 17.6 1.2 20.6 13.3 17.5 1.4 20.6 11.8 150 5 152 165 2.7 0.2 3.3 2.3 12/08/2006 01:40:00 16.4 1.3 19.1 11.8 16.4 1.3 19.1 11.8 16.3 1.4 19.1 12.2 151 4 148 165 2.2 0 2.6 1.6 12/08/2006 01:50:00 14.3 1.2 17.2 10.7 14.2 1.2 17.2 10.3 14.2 1.5 17.9 9.9 154 11 154 165 2.1 0 2.3 1.6 12/08/2006 02:00:00 13.1 0.9 15.3 10.7 13 0.8 14.9 11.1 12.9 1 15.6 9.9 152 5 149 165 2.1 0.1 2.3 1.6 12/08/2006 02:10:00 12 0.9 14.1 9.5 11.8 0.8 13.7 9.5 12.1 0.9 14.1 9.5 155 5 162 165 2.1 0.2 2.6 1.6 12/08/2006 02:20:00 10.4 0.6 12.2 8.8 10.3 0.6 11.8 8.8 10.5 0.6 12.2 8.4 155 5 149 165 2.3 0.1 2.8 1.8 12/08/2006 02:30:00 8.7 0.8 10.7 7.2 8.6 0.8 10.3 6.8 8.8 0.8 11.1 7.2 152 4 157 165 2.5 0 2.8 2.3 12/08/2006 02:40:00 7.3 0.4 8.4 6.5 7.2 0.4 8 6.5 7.4 0.4 8.4 6.5 156 3 159 165 2.5 0 2.8 2.3 12/08/2006 02:50:00 8.1 1.2 11.8 6.1 7.8 1.2 11.5 5.7 8.2 1.3 13 6.1 163 8 180 165 2.4 0 2.8 2.1 12/08/2006 03:00:00 8.7 0.8 10.7 6.1 8.4 0.7 10.3 6.1 8.9 0.8 10.3 7.2 172 11 166 165 1.9 0.1 2.3 1.4 12/08/2006 03:10:00 8.6 0.9 11.5 6.8 8.5 0.9 11.5 6.5 8.6 0.8 10.7 6.8 186 8 184 165 1.9 0 2.3 1.8 12/08/2006 03:20:00 8.5 1.2 11.5 4.9 8.5 1.2 11.1 4.9 8.6 1.1 11.1 5.3 191 6 193 165 1.9 0 2.1 1.6 12/08/2006 03:30:00 9.1 0.7 10.7 7.2 9.2 0.7 10.7 7.2 9.2 0.9 10.7 6.5 192 6 187 165 1.8 0 1.8 1.6 12/08/2006 03:40:00 9.5 0.8 11.5 7.6 9.6 0.8 11.1 7.6 9.7 1 11.8 7.2 194 5 193 165 1.9 0 2.1 1.8 12/08/2006 03:50:00 10.1 0.7 12.6 8 10.3 0.7 13 8 10.4 0.8 12.6 8 196 4 197 165 1.9 0 2.1 1.6 12/08/2006 04:00:00 9.9 0.7 11.8 7.6 10.1 0.7 12.2 8 10.1 1 12.6 7.2 195 5 197 165 1.9 0 2.3 1.8 12/08/2006 04:10:00 10.2 0.7 11.8 7.6 10.4 0.7 11.8 7.2 10.2 0.9 11.8 7.6 198 5 199 165 1.9 0.1 2.3 1.4 12/08/2006 04:20:00 10.2 0.9 12.6 7.6 10.4 0.9 12.6 8 10.5 1.1 13 7.2 193 4 194 165 2 0.1 2.3 1.6 12/08/2006 04:30:00 10.2 0.7 11.5 8 10.3 0.7 11.8 8 10.4 0.8 12.2 8 192 4 198 165 2 0.1 2.3 1.6 12/08/2006 04:40:00 10.9 0.9 12.6 7.6 10.9 0.9 13 7.6 11 1.1 13 8 190 5 194 165 2 0 2.3 1.6 12/08/2006 04:50:00 10.3 1 13 7.6 10.2 1 12.6 7.6 10.1 1.2 12.6 7.2 185 8 194 165 1.8 0.1 2.3 1.4 12/08/2006 05:00:00 9.6 0.9 11.8 7.2 9.4 0.8 11.1 7.2 9.4 0.9 11.8 6.8 183 7 185 165 1.8 0.1 2.1 1.4 12/08/2006 05:10:00 9.2 0.8 11.1 6.8 9 0.8 11.1 6.5 9.1 0.8 11.1 6.8 181 6 193 165 1.8 0.2 1.8 1.4 12/08/2006 05:20:00 9.3 0.8 11.1 6.8 9.2 0.8 11.1 7.2 9.1 1 11.5 6.8 184 5 189 165 1.8 0.2 2.1 1.4 12/08/2006 05:30:00 8.5 0.9 10.3 5.7 8.5 0.9 10.7 5.7 8.4 0.8 10.3 5.3 190 8 198 165 1.8 0.2 2.1 1.4 12/08/2006 05:40:00 7.9 0.8 9.9 5.7 7.9 0.8 9.9 5.7 7.8 0.9 10.3 5.3 198 6 196 165 1.8 0.2 2.1 1.4 12/08/2006 05:50:00 8.1 0.8 9.9 6.1 8.3 0.9 10.3 6.1 8.1 1 10.7 6.1 203 5 202 165 1.8 0.1 2.1 1.4 12/08/2006 06:00:00 7.6 0.6 9.1 5.7 7.8 0.6 9.1 5.7 7.7 0.8 9.5 5.3 203 4 206 165 1.7 0.2 2.1 1.4 12/08/2006 06:10:00 7.6 0.7 9.1 5.3 7.7 0.7 9.5 5.3 7.6 0.8 9.1 5.7 200 4 206 165 1.8 0.2 1.8 1.4 12/08/2006 06:20:00 7.8 0.6 9.1 6.1 7.9 0.6 9.1 6.1 7.8 0.7 9.5 6.1 195 4 199 165 1.8 0.2 2.1 1.4 12/08/2006 06:30:00 7.5 0.5 8.8 6.1 7.5 0.5 9.1 6.1 7.4 0.6 9.1 5.7 190 4 189 165 1.9 0 2.1 1.6 12/08/2006 06:40:00 7.1 0.4 8 5.7 7.1 0.4 8 5.7 7.2 0.6 8.4 5.3 189 4 183 165 1.9 0 2.1 1.8 12/08/2006 06:50:00 6.6 0.6 8 5.3 6.5 0.6 8 4.9 6.6 0.7 8.8 4.9 182 5 187 165 1.8 0 1.8 1.6 12/08/2006 07:00:00 5.4 0.6 6.8 3.8 5.2 0.6 6.5 3.8 5.3 0.6 6.8 3.8 174 6 176 165 1.6 0 1.8 1.1 12/08/2006 07:10:00 5.6 0.6 7.2 3.4 5.5 0.6 6.8 3.8 5.5 0.6 6.8 4.2 168 9 171 165 1.8 0 1.8 1.6 12/08/2006 07:20:00 4.5 0.6 6.1 3 4.4 0.6 6.1 3.4 4.6 0.6 6.1 3 161 9 165 165 1.8 0 1.8 1.6 12/08/2006 07:30:00 4.5 0.5 5.7 3.4 4.4 0.5 5.7 3.4 4.5 0.5 5.7 3.4 161 5 155 165 1.8 0 2.1 1.6 12/08/2006 07:40:00 5.4 0.7 7.2 3.8 5.3 0.6 6.8 3.8 5.6 0.7 7.6 3.8 162 6 162 165 1.9 0 2.1 1.6 12/08/2006 07:50:00 6.3 0.4 7.2 4.9 6.1 0.4 6.8 4.9 6.4 0.4 7.2 4.9 163 4 165 165 2 0 2.3 1.8 12/08/2006 08:00:00 6.2 0.3 6.8 5.3 5.9 0.3 6.5 4.9 6.2 0.3 6.8 5.3 166 11 163 165 2 0 2.3 1.8 12/08/2006 08:10:00 5.9 0.3 6.5 5.3 5.7 0.2 6.1 5.3 6 0.3 6.5 5.3 163 7 165 165 1.9 0 2.3 1.6 12/08/2006 08:20:00 6.1 0.4 6.8 4.9 5.8 0.4 6.8 4.9 6 0.4 6.8 4.9 165 9 166 165 1.9 0 2.3 1.6 12/08/2006 08:30:00 5.6 0.4 6.5 4.6 5.4 0.4 6.5 4.6 5.6 0.4 6.5 4.6 162 5 161 165 1.9 0 2.1 1.8 12/08/2006 08:40:00 6.1 0.5 7.2 4.9 5.8 0.4 6.8 4.6 6.1 0.4 6.8 4.9 166 4 160 165 1.9 0 2.1 1.4 12/08/2006 08:50:00 5.9 0.4 6.8 4.9 5.7 0.4 6.5 4.9 5.9 0.3 6.8 5.3 167 4 166 165 1.8 0 2.1 1.6 12/08/2006 09:00:00 5.4 0.4 6.1 4.6 5.3 0.4 6.1 4.2 5.4 0.3 6.1 4.6 166 8 165 165 1.8 0 1.8 1.4 12/08/2006 09:10:00 5.6 0.6 7.2 4.6 5.4 0.6 7.2 4.6 5.4 0.5 6.8 4.6 167 3 166 165 1.7 0 1.8 1.4 12/08/2006 09:20:00 6.8 0.6 7.6 4.9 6.6 0.6 7.6 4.6 6.5 0.6 7.6 4.9 169 4 166 165 1.8 0 2.1 1.6 12/08/2006 09:30:00 7.2 0.5 8 5.7 6.9 0.4 8 5.7 7.1 0.5 8 5.7 170 4 165 165 1.9 0.1 2.3 1.4 12/08/2006 09:40:00 6 0.5 7.2 4.9 5.8 0.5 6.8 4.6 5.8 0.5 7.2 4.2 169 3 168 165 1.8 0.2 2.3 1.4 12/08/2006 09:50:00 5 0.5 6.1 3.4 4.8 0.5 6.1 3.4 4.7 0.6 6.1 3.4 171 4 166 165 1.9 0.1 2.3 1.4 12/08/2006 10:00:00 4.9 0.3 5.7 3.8 4.7 0.3 5.3 3.8 4.9 0.5 5.7 3.4 169 3 168 165 2 0.2 2.6 1.4 12/08/2006 10:10:00 4.4 0.5 5.3 3 4.3 0.5 5.3 2.6 4.4 0.5 5.3 2.6 167 10 165 165 2.1 0 2.3 1.6 12/08/2006 10:20:00 3.4 0.5 4.9 2.3 3.3 0.5 4.6 2.3 3.5 0.4 4.6 2.6 163 4 162 165 2 0.1 2.6 1.6 12/08/2006 10:30:00 2.6 0.5 3.8 1.5 2.6 0.5 3.8 1.5 2.7 0.4 3.8 1.9 158 6 153 165 2.1 0.2 2.6 1.4 12/08/2006 10:40:00 3.4 0.4 4.2 2.3 3.3 0.4 3.8 2.3 3.4 0.5 4.2 2.3 157 4 162 165 2.3 0.2 2.8 1.8 12/08/2006 10:50:00 2.3 0.5 3.4 1.1 2.2 0.5 3.4 1.1 2.4 0.4 3.4 1.1 157 5 153 165 2.4 0.1 2.8 1.8 12/08/2006 11:00:00 1.6 0.4 2.3 0.7 1.7 0.4 2.3 1.1 1.8 0.4 2.6 0.7 165 2 162 165 2.4 0.1 2.8 2.1 12/08/2006 11:10:00 1.3 0.4 2.3 0.4 1.3 0.4 2.3 0.4 1.5 0.3 2.6 0.7 155 6 144 165 2.4 0.2 2.8 2.1 12/08/2006 11:20:00 1.8 0.5 2.6 0.4 1.8 0.5 2.6 0.4 1.9 0.5 3 0.7 140 4 138 165 2.6 0.1 2.8 2.1 12/08/2006 11:30:00 1.5 0.3 2.3 0.7 1.4 0.3 2.3 0.7 1.6 0.3 2.3 1.1 140 2 139 165 2.7 0.1 3 2.3 12/08/2006 11:40:00 0.6 0.3 1.1 0.4 0.5 0.3 1.1 0.4 0.7 0.4 1.5 0.4 139 3 142 165 2.8 0.1 3 2.6 12/08/2006 11:50:00 0.4 0.2 1.5 0.4 0.4 0.2 1.5 0.4 0.6 0.4 1.9 0.4 120 20 108 165 2.9 0 3 2.6 12/08/2006 12:00:00 2.6 1 4.6 0.7 2.7 1 4.6 1.1 2.7 1 4.6 0.7 87 19 65 165 2.7 0.1 3 2.3 12/08/2006 12:10:00 4.3 0.6 6.1 3 4.4 0.6 6.1 3.4 4.5 0.5 6.5 3.4 52 8 52 165 2.1 0.3 2.8 1.4 12/08/2006 12:20:00 4.5 0.5 5.7 3.4 4.5 0.5 5.7 3.4 4.6 0.6 6.1 3.4 40 7 31 165 1.7 0 1.8 1.6 12/08/2006 12:30:00 4.7 0.3 5.7 3.8 4.7 0.4 5.7 3.4 4.9 0.3 6.1 4.2 39 8 51 165 1.6 0 1.8 1.4 12/08/2006 12:40:00 4.4 0.5 6.1 3.4 4.2 0.5 6.1 3 4.4 0.5 6.5 3.4 24 6 29 165 1.5 0 1.6 1.4 12/08/2006 12:50:00 5.5 0.4 6.5 4.2 4.5 0.8 6.1 2.6 5.5 0.5 6.5 3.8 14 3 18 165 1.2 0 1.6 0.9 12/08/2006 13:00:00 5.7 0.4 6.8 4.6 4 1 6.5 1.9 5.7 0.5 6.5 4.2 10 5 16 165 0.9 0.1 1.4 0.9 12/08/2006 13:10:00 5.1 0.4 6.1 4.2 4 0.8 5.3 1.9 5 0.4 5.7 3.4 13 5 6 165 0.8 0.1 0.9 0.2 12/08/2006 13:20:00 5 0.4 6.1 3.4 3.5 0.8 5.7 1.9 4.9 0.5 6.1 3.4 7 8 12 165 0.7 0.1 0.9 0.2 12/08/2006 13:30:00 5.8 0.6 7.2 4.6 4.3 1.5 7.6 2.3 5.7 0.5 7.6 4.6 355 5 351 165 0.6 0.1 0.9 0.2 12/08/2006 13:40:00 6.2 0.8 8.4 3.8 6.1 1 8.4 3 5.8 0.9 8.4 2.6 346 6 342 165 0.6 0 0.9 0.2 12/08/2006 13:50:00 6 1 8.8 3.8 5.8 1 9.1 3.4 5.6 1 8.4 3 345 8 351 165 0.5 0 0.7 0.2 12/08/2006 14:00:00 6 0.8 8 3.4 5.8 0.9 8.4 3 5.5 0.7 7.2 3.4 344 8 349 165 0.4 0 0.7 -0.1 12/08/2006 14:10:00 6.4 0.8 8.4 4.6 5.8 1 8.4 3.4 6.2 0.8 9.5 4.6 350 7 345 165 0.5 0.1 0.9 0.2 12/08/2006 14:20:00 7.3 1.1 10.3 4.2 6 1.6 9.9 2.6 7.4 1 10.3 4.6 354 12 352 165 0.8 0 1.1 0.4 12/08/2006 14:30:00 3.9 1 6.5 1.9 3.9 1 6.1 1.9 3.8 0.9 6.1 1.1 216 94 239 165 0.9 0.1 1.1 0.7 12/08/2006 14:40:00 5.8 1 8.4 3.8 6.6 1 8 3.8 6.3 1.1 8 3.4 261 15 249 165 0.5 0.1 0.9 -0.1 12/08/2006 14:50:00 6.1 0.5 7.6 4.6 6.1 0.5 7.6 4.6 5.2 1 7.6 3 297 10 275 165 0.8 0.1 1.1 0.2 12/08/2006 15:00:00 4.7 0.5 6.1 3.4 4.8 0.5 6.1 3.4 3.7 0.6 5.7 2.3 303 9 314 165 1.3 0.1 1.6 0.4 12/08/2006 15:10:00 6 0.7 7.2 4.6 6.2 0.7 7.6 4.6 4.6 0.8 6.8 3 298 5 295 165 1.5 0.1 1.8 0.9 12/08/2006 15:20:00 5.8 0.8 7.2 4.2 6 0.8 7.2 4.2 4.8 1 6.8 2.6 305 5 304 165 1.3 0 1.4 0.9 12/08/2006 15:30:00 4 0.6 5.3 2.3 4.3 0.6 5.3 2.6 4 0.6 5.3 2.6 278 8 289 165 1.1 0.1 1.4 0.7 12/08/2006 15:40:00 2.3 0.5 3.8 1.1 2.5 0.6 4.2 0.7 2.3 0.6 3.8 0.7 227 33 268 165 1.1 0.1 1.4 0.2 12/08/2006 15:50:00 3.2 1.1 4.9 0.7 3.1 1 4.6 0.7 3 1.1 4.9 0.7 200 16 192 165 0.7 0 1.1 0.4 12/08/2006 16:00:00 2.8 0.5 3.8 1.9 2.4 0.5 3.4 1.5 2.8 0.5 4.2 1.5 180 8 181 165 0.3 0.1 0.9 -0.1 12/08/2006 16:10:00 3.7 0.7 4.9 2.3 3.3 0.7 4.6 1.5 3.7 0.8 4.9 1.9 179 6 180 165 0.2 0.1 0.7 -0.1 12/08/2006 16:20:00 4.3 0.6 5.7 3 4 0.6 5.7 2.6 4.5 0.5 6.1 3 175 6 177 165 0.7 0.2 0.9 0.2 12/08/2006 16:30:00 6.1 0.4 7.2 5.3 5.8 0.4 6.5 4.9 6.2 0.4 7.2 5.3 170 6 177 165 0.8 0 0.9 0.7 12/08/2006 16:40:00 5.5 0.4 6.5 4.6 5.3 0.4 6.1 4.2 5.7 0.5 6.8 4.6 167 9 168 165 0.8 0 0.9 0.7 12/08/2006 16:50:00 4.9 0.5 6.5 3.8 4.7 0.5 6.1 3.8 5 0.4 6.1 4.2 172 7 171 165 0.8 0 0.9 0.7 12/08/2006 17:00:00 5.4 0.7 6.8 3.8 5.2 0.7 6.5 3.4 5.2 0.7 6.5 3.4 181 7 185 165 0.6 0 0.9 0.2 12/08/2006 17:10:00 4.7 0.9 6.5 3.4 4.4 0.9 6.1 3 4.6 0.9 6.5 3.4 175 7 180 165 0.5 0 0.7 0.2 12/08/2006 17:20:00 3.7 0.3 4.6 3 3.5 0.3 4.6 3 3.5 0.3 4.6 2.6 180 5 179 165 0.5 0 0.9 0.2 12/08/2006 17:30:00 4.7 0.4 5.7 3.4 4.4 0.4 5.3 3 4.6 0.5 5.3 3 172 7 180 165 0.4 0 0.7 -0.1 12/08/2006 17:40:00 5.2 0.3 6.1 4.6 4.9 0.3 5.7 4.2 5.1 0.3 5.7 4.2 171 5 178 165 0.5 0.1 0.9 0.2 12/08/2006 17:50:00 4.6 0.5 5.7 3.4 4.5 0.4 5.3 3.4 4.5 0.5 5.3 3.4 184 5 175 165 0.8 0.1 1.1 0.2 12/08/2006 18:00:00 4 0.5 5.3 2.6 4 0.5 5.3 3 4.1 0.5 5.3 3 193 7 184 165 1 0 1.6 0.7 12/08/2006 18:10:00 5.1 1 6.8 2.6 5 0.9 6.8 2.3 5.2 0.9 6.8 2.6 182 12 182 165 1 0 1.4 0.7 12/08/2006 18:20:00 6.5 0.8 8 4.9 6.2 0.7 7.6 4.9 6.5 0.7 8 4.9 166 13 164 165 1 0.1 1.4 0.4 12/08/2006 18:30:00 5.6 0.5 6.5 4.6 5.4 0.4 6.5 4.6 5.5 0.4 6.5 4.6 166 10 164 165 1.2 0.1 1.4 0.7 12/08/2006 18:40:00 6.1 1.3 10.3 4.2 6 1.3 10.3 4.2 6 1.3 10.3 4.2 159 7 148 165 1.1 0 1.4 0.7 12/08/2006 18:50:00 8.8 0.8 11.1 6.8 8.6 0.7 10.7 6.5 8.8 0.8 11.1 7.2 156 6 157 165 1.5 0.1 1.8 0.9 12/08/2006 19:00:00 7.4 1.3 10.7 5.3 7.1 1.3 10.3 5.3 7.4 1.3 10.3 5.3 161 5 158 165 1.5 0.1 1.6 0.9 12/08/2006 19:10:00 5 0.7 6.1 3.4 4.9 0.7 6.1 3.4 5.1 0.7 6.5 3.8 158 5 157 165 1.4 0.1 1.6 0.9 12/08/2006 19:20:00 3.6 0.4 4.6 2.6 3.5 0.4 4.6 2.6 3.6 0.4 4.6 2.6 169 5 180 165 1.3 0.1 1.6 0.9 12/08/2006 19:30:00 4 0.7 5.7 2.6 3.9 0.7 5.7 2.6 4 0.7 5.7 2.6 161 6 154 165 1.3 0.1 1.6 0.9 12/08/2006 19:40:00 5.4 0.6 7.2 4.2 5.3 0.5 6.8 3.8 5.5 0.5 7.2 4.2 153 5 160 165 1.3 0.1 1.6 0.9 12/08/2006 19:50:00 5.4 0.4 6.5 4.2 5.3 0.3 6.1 4.2 5.4 0.4 6.1 4.6 154 5 150 165 1.2 0.1 1.4 0.7 12/08/2006 20:00:00 6 0.4 6.8 4.9 5.8 0.4 6.8 4.6 5.9 0.4 6.8 4.9 156 2 155 165 1.2 0.1 1.4 0.7 12/08/2006 20:10:00 6.1 0.5 7.2 4.9 5.9 0.5 7.2 4.9 6 0.5 7.2 4.9 157 4 156 165 1.4 0.1 1.6 1.1 12/08/2006 20:20:00 6.6 0.7 8 5.3 6.5 0.6 8 4.9 6.7 0.6 8.8 5.3 155 3 153 165 1.5 0 1.8 1.4 12/08/2006 20:30:00 7.4 0.6 8.8 6.5 7.2 0.5 8.4 6.1 7.5 0.5 8.8 6.5 156 2 156 165 1.7 0 1.8 1.4 12/08/2006 20:40:00 7.6 0.6 9.1 6.5 7.4 0.6 8.8 6.5 7.5 0.6 9.1 6.1 153 3 158 165 1.8 0 1.8 1.6 12/08/2006 20:50:00 8 0.4 8.8 6.8 7.9 0.4 8.8 6.8 8 0.5 9.1 6.8 151 3 150 165 1.8 0 1.8 1.8 12/08/2006 21:00:00 7.4 0.8 9.1 5.7 7.4 0.7 9.1 5.3 7.3 0.8 8.8 4.9 148 5 147 165 1.9 0 2.1 1.8 12/08/2006 21:10:00 8.7 0.4 9.5 7.6 8.6 0.4 9.5 7.2 8.6 0.5 9.9 7.2 149 3 149 165 2 0 2.3 1.8 12/08/2006 21:20:00 9.1 0.6 10.3 6.8 9 0.6 10.3 7.2 9 0.7 10.3 6.8 152 3 151 165 2.1 0 2.3 1.8 12/08/2006 21:30:00 8.7 0.5 9.9 7.2 8.6 0.5 9.9 7.2 8.6 0.6 9.9 7.2 153 3 155 165 2.1 0 2.3 1.8 12/08/2006 21:40:00 7.9 0.5 9.5 6.8 7.9 0.5 9.5 6.8 7.8 0.6 9.1 6.5 150 6 147 165 2.1 0 2.3 2.1 12/08/2006 21:50:00 8.7 0.5 9.9 7.2 8.6 0.5 9.9 7.2 8.7 0.6 9.9 6.8 151 5 147 165 2.1 0 2.3 1.8 12/08/2006 22:00:00 8.4 0.5 9.9 6.8 8.4 0.5 9.9 6.8 8.3 0.5 9.5 6.8 150 5 145 165 2 0 2.3 1.8 12/08/2006 22:10:00 8.1 0.6 9.5 6.5 8 0.5 9.5 6.5 8 0.7 9.5 5.7 150 4 156 165 1.9 0 2.1 1.8 12/08/2006 22:20:00 7.7 0.7 9.5 5.7 7.7 0.7 9.5 5.3 7.5 0.8 9.1 5.3 147 5 139 165 2 0 2.3 1.8 12/08/2006 22:30:00 9.8 0.7 11.1 7.6 9.8 0.7 11.5 7.6 9.6 0.9 11.5 6.5 150 4 153 165 2.1 0 2.3 1.8 12/08/2006 22:40:00 10 0.7 12.2 8.4 10 0.7 12.2 8.4 9.9 0.8 11.8 8 147 5 139 165 2.3 0 2.6 1.8 12/08/2006 22:50:00 11.2 0.8 12.6 9.1 11.2 0.8 12.6 8.8 11 0.9 13 8.4 145 4 145 165 2.3 0 2.6 1.8 12/08/2006 23:00:00 13.7 2.9 21.4 9.9 13.7 2.9 21.4 10.3 13.5 2.9 22.1 9.1 145 5 152 165 2.3 0.2 2.6 1.4 12/08/2006 23:10:00 12.9 1.8 17.9 10.7 13 1.9 17.9 10.3 12.6 1.8 17.9 10.3 144 3 145 165 1.4 0.2 1.8 0.9 12/08/2006 23:20:00 12.2 1.1 15.3 9.5 12.1 1 15.3 9.5 11.8 1.1 15.3 9.5 147 5 151 165 1.6 0.2 2.1 0.9 12/08/2006 23:30:00 15 1.1 17.2 11.8 14.9 1.1 17.2 11.5 14.5 1.3 17.2 10.7 145 5 144 165 2.2 0.1 2.6 1.6 12/08/2006 23:40:00 15.2 1.1 17.6 12.2 15.2 1.1 17.6 11.8 14.9 1.2 17.6 10.7 145 5 145 165 2.3 0 2.6 1.8 12/08/2006 23:50:00 18.5 2.7 25.6 13.3 18.3 2.6 24.8 13.7 18.5 2.8 24.4 12.6 151 11 150 165 1.8 0.6 2.6 0.7 12/09/2006 00:00:00 14.4 3.1 19.5 8.8 14.2 2.9 19.1 8.8 14.3 3.2 19.1 8.8 154 6 151 165 0.8 0.2 1.4 0.4 12/09/2006 00:10:00 10.4 1 12.6 8 10.3 1 13 8 10.4 1 13 8 154 5 160 165 0.8 0.1 1.1 0.4 12/09/2006 00:20:00 9 0.9 11.1 6.5 9 0.9 11.1 6.5 8.9 1 11.1 6.1 154 4 163 165 1 0 1.4 0.7 12/09/2006 00:30:00 8.3 0.8 10.3 6.5 8.4 0.8 10.7 6.5 8.1 1 10.7 5.7 148 8 154 165 1.3 0.1 1.6 0.9 12/09/2006 00:40:00 8.8 1.1 12.2 6.5 8.9 1.1 12.2 6.5 8.7 1 12.2 6.1 143 6 144 165 1.7 0.1 1.8 1.4 12/09/2006 00:50:00 12.1 0.9 14.1 9.9 12.1 0.9 14.5 9.9 11.9 1 14.9 9.1 142 6 147 165 1.9 0.1 2.1 1.4 12/09/2006 01:00:00 13 1.3 16.1 9.5 13 1.2 16.1 9.9 12.8 1.3 15.3 9.5 141 6 144 165 1.9 0.1 2.3 1.6 12/09/2006 01:10:00 14.1 1.3 18.3 11.5 14.1 1.2 17.9 11.5 13.9 1.3 18.7 11.1 142 6 145 165 2 0 2.3 1.8 12/09/2006 01:20:00 17.2 1.9 22.6 13.3 17.1 1.8 22.6 13 17.1 2.1 22.1 11.8 155 14 156 165 2 0.4 2.6 1.1 12/09/2006 01:30:00 16.1 1.9 19.5 11.1 16 1.9 19.5 10.3 15.5 1.8 20.2 11.5 156 12 167 165 0.7 0.2 1.4 0.2 12/09/2006 01:40:00 13.9 1.1 16.4 11.1 13.9 1.1 16.4 10.7 13.4 1.3 16.1 9.9 149 4 145 165 0.7 0.2 1.4 -0.1 12/09/2006 01:50:00 13.3 1.1 16.4 11.1 13.3 1.1 16.1 11.1 12.9 1.1 16.1 9.9 150 4 151 165 1.3 0 1.6 1.1 12/09/2006 02:00:00 13.7 1.4 17.2 10.3 13.9 1.4 17.2 10.7 13.3 1.5 17.2 8.8 148 5 151 165 1.4 0 1.8 1.4 12/09/2006 02:10:00 16 1.2 18.7 13 15.9 1.2 19.1 12.2 15.9 1.3 18.7 11.8 145 5 144 165 1.6 0 1.8 1.4 12/09/2006 02:20:00 15 0.8 16.4 12.6 15.2 0.9 16.8 13 14.7 1 16.8 12.2 147 3 153 165 1.7 0 1.8 1.6 12/09/2006 02:30:00 13.1 0.9 14.9 10.3 13.3 0.9 15.3 11.1 13.1 1 15.3 10.3 148 3 150 165 1.7 0.1 1.8 1.4 12/09/2006 02:40:00 12.9 0.8 15.3 10.7 12.9 0.8 15.3 10.7 12.8 0.9 14.9 9.9 149 3 150 165 1.8 0.1 2.1 1.4 12/09/2006 02:50:00 12.8 1.5 17.2 9.1 12.6 1.5 16.8 9.1 12.5 1.6 16.8 8.8 153 13 145 165 2 0 2.3 1.6 12/09/2006 03:00:00 12.2 1.1 14.9 8.8 12 1 14.9 8.4 12 1.1 14.9 8.4 158 5 162 165 1.8 0 2.1 1.4 12/09/2006 03:10:00 14.9 2.5 19.5 8.4 14.8 2.4 19.5 8.4 14.3 2.5 19.9 8 148 6 149 165 2.1 0 2.3 1.8 12/09/2006 03:20:00 14.4 1 16.4 11.8 14.3 1 16.4 11.5 14.2 1.1 16.8 11.5 150 4 156 165 2.3 0 2.6 1.8 12/09/2006 03:30:00 13.5 1 16.4 10.7 13.4 1 16.1 11.1 13.5 1 15.6 10.7 154 5 151 165 2.3 0 2.6 2.1 12/09/2006 03:40:00 13.2 1.3 16.8 8.4 13.1 1.3 16.8 8.4 12.8 1.4 16.1 7.6 156 8 164 165 2.2 0.1 2.6 1.4 12/09/2006 03:50:00 14.4 2.1 19.5 10.3 14.3 2 19.5 11.1 14.1 2.3 19.5 10.3 157 10 146 165 2 0 2.3 1.8 12/09/2006 04:00:00 14.6 1.2 17.6 11.5 14.5 1.2 17.6 11.5 14.2 1.4 16.8 11.1 158 13 157 165 1.8 0.1 2.3 1.4 12/09/2006 04:10:00 12.1 1.4 16.4 9.1 12 1.4 16.1 8.8 12 1.6 16.1 8.4 154 10 162 165 1.9 0.1 2.3 1.6 12/09/2006 04:20:00 11.2 0.7 13.3 8.8 11.2 0.7 13.3 8.8 11 0.8 13 8.4 150 4 147 165 2.2 0 2.6 1.8 12/09/2006 04:30:00 12.1 0.8 13.7 9.9 12.1 0.8 13.7 10.3 11.9 0.9 14.5 9.5 151 4 151 165 2.2 0 2.6 1.8 12/09/2006 04:40:00 12 0.8 13.3 9.5 12 0.8 13.7 9.1 11.9 1 14.1 9.1 148 4 150 165 2.3 0 2.6 1.8 12/09/2006 04:50:00 12.2 0.9 14.5 9.1 12.2 0.9 14.1 9.5 11.9 1 14.1 8.8 146 5 145 165 2.4 0 2.6 2.3 12/09/2006 05:00:00 12.6 0.8 14.1 9.5 12.6 0.8 14.1 9.9 12.3 0.9 14.1 9.1 146 4 142 165 2.4 0 2.6 1.8 12/09/2006 05:10:00 12.7 0.7 14.5 9.9 12.7 0.8 14.9 10.3 12.4 0.8 14.1 9.1 145 5 156 165 2.4 0 2.6 1.8 12/09/2006 05:20:00 13.6 1 16.8 11.1 13.6 1 16.8 11.1 13.4 1.1 16.4 10.7 146 5 149 165 2.5 0 2.8 2.3 12/09/2006 05:30:00 15.4 1.7 20.6 11.1 15.5 1.7 20.6 10.7 15.1 2 21 8.8 145 4 144 165 2 0.2 2.6 1.6 12/09/2006 05:40:00 13.3 1.1 16.8 11.1 13.3 1.1 16.4 11.1 13.1 1.1 16.1 10.3 148 4 151 165 2.1 0 2.3 1.8 12/09/2006 05:50:00 13.6 1.1 16.1 10.3 13.6 1.1 16.1 10.3 13.4 1.2 16.1 9.5 146 4 148 165 2.4 0 2.6 1.8 12/09/2006 06:00:00 14 0.8 16.1 11.8 14 0.8 16.4 12.2 13.9 0.9 15.6 9.9 149 3 150 165 2.4 0 2.6 2.3 12/09/2006 06:10:00 15.2 1.2 17.6 11.8 15.2 1.3 17.6 11.8 14.6 1.5 17.2 11.1 145 5 148 165 2.4 0 2.6 2.3 12/09/2006 06:20:00 15.1 1 17.2 12.2 15 1 16.8 11.8 14.9 1.1 17.2 11.8 147 4 149 165 2.4 0 2.6 2.3 12/09/2006 06:30:00 13.2 0.9 14.9 10.3 13 0.9 14.9 10.3 12.7 1 14.9 9.1 147 4 139 165 2.5 0 2.8 2.1 12/09/2006 06:40:00 13.2 0.8 14.9 10.7 13.1 0.7 14.9 11.1 12.7 1 15.3 9.9 148 4 151 165 2.5 0.1 2.8 2.3 12/09/2006 06:50:00 14.4 0.9 16.1 11.8 14.4 0.9 16.1 11.8 14.1 1 16.1 9.9 145 4 146 165 2.5 0 2.6 2.3 12/09/2006 07:00:00 14.1 1 16.4 11.1 14 1 16.4 11.5 13.8 1.1 16.4 11.1 147 4 137 165 2.5 0 2.6 2.3 12/09/2006 07:10:00 13.4 1 15.6 11.1 13.4 1 15.6 10.7 13.2 1.1 15.6 9.9 146 4 149 165 2.6 0 2.8 2.6 12/09/2006 07:20:00 13.1 1 15.3 9.9 13.1 1 15.3 10.3 12.8 1.1 15.3 9.5 146 4 148 165 2.5 0 2.8 2.6 12/09/2006 07:30:00 13.2 0.9 15.6 10.7 13.1 0.8 15.3 10.7 12.9 1 14.9 9.9 148 4 143 165 2.4 0.2 2.6 1.8 12/09/2006 07:40:00 12.1 0.9 15.3 9.9 12.1 0.9 15.3 10.3 11.9 1 14.9 9.5 147 4 143 165 2.5 0.2 2.8 1.8 12/09/2006 07:50:00 13 1 14.9 9.5 12.9 1 15.3 9.1 12.6 1.2 15.3 9.1 147 5 146 165 2.6 0 2.8 2.1 12/09/2006 08:00:00 13.4 0.9 15.3 10.7 13.4 0.9 15.3 10.7 13 1 15.6 9.9 146 4 146 165 2.6 0.2 2.8 1.8 12/09/2006 08:10:00 13.4 0.8 15.3 11.1 13.4 0.9 15.3 10.7 13 1 14.9 10.3 148 4 152 165 2.6 0.2 2.8 1.8 12/09/2006 08:20:00 13.3 1.1 16.1 10.3 13.2 1.1 16.1 9.9 12.8 1.1 15.6 9.9 146 4 145 165 2.5 0.1 2.8 2.1 12/09/2006 08:30:00 13.7 0.9 15.6 10.7 13.7 0.9 15.6 10.7 13.3 1 15.3 10.3 147 4 151 165 2.4 0.3 2.8 1.8 12/09/2006 08:40:00 14.3 0.9 16.1 11.5 14.2 0.9 16.1 11.8 13.9 1.1 16.1 10.3 145 4 145 165 2.6 0.1 2.8 2.1 12/09/2006 08:50:00 14.5 1.1 17.2 11.1 14.4 1 16.8 11.5 14 1.1 16.1 9.1 147 4 145 165 2.6 0 2.8 2.1 12/09/2006 09:00:00 13.8 1.3 17.6 10.7 13.6 1.3 16.8 10.7 13.6 1.3 16.8 10.3 158 13 153 165 2.2 0.5 2.8 0.9 12/09/2006 09:10:00 12.7 1.7 17.2 7.6 12.6 1.7 16.8 7.6 12.7 1.6 16.8 8 164 10 165 165 1.4 0.1 1.6 0.9 12/09/2006 09:20:00 15.2 1.7 18.3 10.3 14.7 1.7 17.9 9.9 14.7 1.7 17.9 9.5 159 14 163 165 1.4 0.1 1.8 0.9 12/09/2006 09:30:00 12.1 0.8 14.5 9.9 11.7 0.8 14.1 9.5 12 0.8 14.1 9.5 156 5 162 165 1.4 0 1.6 0.9 12/09/2006 09:40:00 13 0.9 15.3 10.7 12.7 0.9 14.9 10.7 12.8 1 14.9 10.3 154 5 145 165 1.6 0 1.8 1.4 12/09/2006 09:50:00 9.7 1.2 13.7 7.6 9.5 1.1 13.3 7.2 9.5 1.2 13.3 6.8 151 5 154 165 1.5 0 1.6 1.4 12/09/2006 10:00:00 9.8 0.8 11.8 7.6 9.7 0.7 11.8 8 9.6 0.8 11.8 7.2 144 6 143 165 1.5 0 1.8 1.4 12/09/2006 10:10:00 10.6 0.8 12.2 8.4 10.4 0.8 11.8 8.4 10.3 0.7 12.2 8.4 148 5 156 165 1.7 0 1.8 1.4 12/09/2006 10:20:00 12.3 1.2 16.1 9.9 12.1 1.2 16.1 9.5 12 1.4 16.1 8.4 151 5 143 165 2 0 2.3 1.6 12/09/2006 10:30:00 11.2 0.9 13.7 8.8 11 0.9 13.7 9.1 10.9 1 13.3 8.8 150 4 157 165 1.9 0 2.3 1.6 12/09/2006 10:40:00 11.1 1.5 14.1 8 11 1.5 14.5 7.6 10.8 1.7 14.9 6.1 150 8 161 165 2 0.1 2.3 1.6 12/09/2006 10:50:00 9.7 0.8 12.2 7.2 9.7 0.8 11.5 7.2 9.5 0.8 11.5 7.2 144 6 159 165 1.8 0 2.1 1.6 12/09/2006 11:00:00 10.5 0.9 12.6 8 10.5 0.8 13 8.4 10.2 0.9 12.2 7.6 146 6 147 165 2 0.1 2.6 1.8 12/09/2006 11:10:00 11.5 0.8 13.3 8.8 11.5 0.8 13.7 8.8 11.2 1 13.3 8 148 6 153 165 2.3 0.2 2.6 1.8 12/09/2006 11:20:00 10.9 1.3 14.1 8 10.8 1.3 14.5 8 10.9 1.4 15.6 8.4 155 6 151 165 2.2 0.1 2.6 1.6 12/09/2006 11:30:00 7.4 0.7 9.5 5.7 7.3 0.6 9.1 5.7 7.5 0.7 9.1 5.7 159 8 163 165 2.1 0.1 2.3 1.8 12/09/2006 11:40:00 9.8 1.8 12.6 6.5 9.8 1.9 12.6 6.5 9.8 1.8 12.6 6.5 148 6 145 165 2.2 0.2 2.6 1.6 12/09/2006 11:50:00 12.6 0.8 14.5 10.7 12.6 0.7 14.5 10.3 12.6 0.9 14.5 10.3 150 3 153 165 2.4 0.1 2.8 2.1 12/09/2006 12:00:00 11.5 0.8 13.7 9.1 11.5 0.8 13.7 9.1 11.4 1 14.1 8.4 150 4 150 165 2.6 0 2.8 2.3 12/09/2006 12:10:00 11.9 0.7 14.1 10.3 11.9 0.7 13.7 10.3 11.7 0.7 13.3 9.9 151 4 148 165 2.6 0 2.8 2.3 12/09/2006 12:20:00 12.1 0.7 14.1 10.3 12 0.7 13.7 9.9 11.7 0.9 13.7 8.8 150 3 148 165 2.5 0.1 2.8 2.1 12/09/2006 12:30:00 13.5 1 16.1 10.7 13.4 1 16.1 10.7 13.5 1.2 16.8 9.9 154 6 157 165 2.4 0.2 2.8 1.8 12/09/2006 12:40:00 13.2 1 15.6 10.3 13 0.9 15.3 9.9 13.4 1 16.1 10.7 156 5 153 165 2.3 0.2 2.6 1.6 12/09/2006 12:50:00 13.8 0.9 16.1 10.7 13.7 0.9 16.1 10.7 14.1 1.1 16.4 10.7 157 10 154 165 2.3 0 2.6 1.6 12/09/2006 13:00:00 12.6 0.9 15.3 10.3 12.5 0.8 15.3 9.9 12.8 0.9 16.1 11.1 156 4 153 165 2.3 0.1 2.6 1.8 12/09/2006 13:10:00 14.8 0.8 17.2 11.8 14.7 0.8 16.8 11.8 14.7 0.9 16.8 11.8 151 3 152 165 2.4 0.2 2.8 1.8 12/09/2006 13:20:00 16.3 1.1 19.9 13.3 16.2 1.1 19.5 13.3 16.4 1.2 19.1 13 151 4 147 165 2.4 0.2 2.8 1.8 12/09/2006 13:30:00 12.9 1.2 16.4 9.9 12.6 1.3 16.4 9.5 13.1 1.3 16.8 9.9 167 10 151 165 2.1 0.2 2.6 1.6 12/09/2006 13:40:00 11 0.8 13.3 9.5 10.7 0.7 12.6 9.5 11.2 0.8 13.7 9.5 168 10 171 165 1.9 0.1 2.3 1.4 12/09/2006 13:50:00 10 0.5 11.5 8.8 9.8 0.5 11.1 8.4 10.2 0.5 11.8 8 163 13 172 165 2 0 2.3 1.6 12/09/2006 14:00:00 9.4 0.5 10.7 7.6 9.3 0.5 10.7 7.2 9.4 0.5 10.3 7.6 162 7 159 165 2 0 2.3 1.8 12/09/2006 14:10:00 11 1.1 13.7 8.4 10.8 1.1 13.7 8 11 1.2 14.1 8 162 13 154 165 2 0.3 2.6 0.9 12/09/2006 14:20:00 10 1 12.6 7.6 9.8 1 12.2 7.2 10 1.2 13 7.2 166 9 170 165 1.4 0 1.6 1.4 12/09/2006 14:30:00 8.1 0.8 10.3 6.1 8 0.8 9.9 6.1 8.2 0.8 10.7 6.5 160 4 157 165 1.4 0 1.6 1.4 12/09/2006 14:40:00 7.8 0.5 9.1 6.5 7.7 0.5 8.8 6.1 7.8 0.6 9.1 6.1 155 4 153 165 1.5 0 1.6 1.4 12/09/2006 14:50:00 8.9 0.9 11.5 7.2 8.8 0.9 11.8 7.2 9 0.8 12.2 7.2 154 4 153 165 1.6 0 1.8 1.4 12/09/2006 15:00:00 12 1.1 15.6 8.8 11.9 1.1 15.6 8.8 12 1.1 14.9 9.1 155 11 148 165 1.7 0.2 1.8 1.4 12/09/2006 15:10:00 11.3 1.2 13.3 8.4 11.3 1.1 13 8 11.4 1.2 14.1 8.4 159 8 162 165 1.5 0 1.6 0.9 12/09/2006 15:20:00 10.3 0.8 11.8 8.4 10.3 0.7 11.8 8.8 10.3 0.8 12.2 8.4 153 4 160 165 1.6 0 1.8 1.4 12/09/2006 15:30:00 10.6 0.8 12.6 8.8 10.7 0.8 12.6 8.8 10.4 1 13 7.2 148 4 153 165 1.7 0 1.8 1.4 12/09/2006 15:40:00 9.8 0.5 11.1 8 9.8 0.5 10.7 8.4 9.5 0.7 11.5 7.2 149 3 149 165 1.8 0 1.8 1.6 12/09/2006 15:50:00 10.6 0.8 13.3 8.4 10.6 0.8 13.3 7.6 10.7 0.8 12.6 7.6 157 8 147 165 1.8 0 1.8 1.4 12/09/2006 16:00:00 9.7 0.8 11.5 7.6 9.5 0.8 11.5 7.6 9.7 0.9 11.8 7.6 164 9 162 165 1.5 0 1.6 1.4 12/09/2006 16:10:00 9.6 0.6 11.1 8 9.4 0.5 10.7 8 9.5 0.6 10.7 7.6 164 0 164 165 1.4 0 1.6 1.4 12/09/2006 16:20:00 9.2 0.4 10.3 8.4 8.9 0.4 9.9 8 8.8 0.4 9.9 8 164 0 164 165 1.3 0 1.6 1.1 12/09/2006 16:30:00 9.9 0.6 11.1 8 9.5 0.6 10.7 8 9.3 0.7 10.7 7.6 164 0 164 165 1.3 0.1 1.6 0.9 12/09/2006 16:40:00 9.9 0.5 11.1 8.4 9.6 0.5 10.7 8.4 9.4 0.5 10.7 8 164 0 164 165 1.3 0.1 1.6 0.9 12/09/2006 16:50:00 9.5 0.5 10.7 7.2 9.2 0.5 10.3 7.2 9.1 0.5 9.9 7.6 164 0 164 165 1.4 0.1 1.6 0.9 12/09/2006 17:00:00 9.5 0.6 11.5 8.4 9.3 0.6 11.1 8 9.4 0.6 11.1 7.6 164 0 163 165 1.4 0.1 1.6 0.9 12/09/2006 17:10:00 10 1.2 13.7 8 9.8 1.2 13.3 8 9.9 1.2 13.7 7.6 166 8 186 165 1.5 0 1.8 1.1 12/09/2006 17:20:00 10.3 1.2 13 7.6 10 1.2 13 7.2 10.2 1.2 13.3 8 167 6 165 165 1.4 0.1 1.8 0.9 12/09/2006 17:30:00 7.2 1 9.9 5.3 7 1 9.9 4.9 7 1 10.3 4.9 165 0 165 165 1.1 0.1 1.6 0.7 12/09/2006 17:40:00 7.2 1.3 12.2 5.3 6.8 1.2 11.5 4.9 6.6 1 10.7 4.9 165 0 165 165 0.9 0 1.4 0.4 12/09/2006 17:50:00 10.3 0.9 13 7.6 9.9 0.9 12.6 7.6 9.8 1 12.2 7.6 165 0 165 165 1.1 0.1 1.4 0.9 12/09/2006 18:00:00 9.6 0.9 12.6 7.6 9.3 0.8 12.2 7.6 9.3 1 12.6 6.8 165 0 165 165 1.2 0.1 1.6 0.9 12/09/2006 18:10:00 10.1 0.7 11.5 8 9.7 0.7 11.1 8 9.9 0.8 11.5 8 165 0 165 165 1.2 0.1 1.6 0.9 12/09/2006 18:20:00 10.8 1.5 14.5 8.4 10.5 1.5 14.1 7.6 10.6 1.6 14.5 7.6 165 0 165 165 1.3 0.1 1.6 0.9 12/09/2006 18:30:00 11.9 1 14.1 9.5 11.5 0.9 13.7 9.1 11.6 1.1 14.1 8 165 0 165 165 1.2 0 1.6 0.9 12/09/2006 18:40:00 9.5 0.7 11.1 8 9.1 0.7 10.7 7.6 9.2 0.6 10.7 7.6 165 0 165 165 1.2 0 1.4 0.9 12/09/2006 18:50:00 8.4 0.6 9.9 6.8 8 0.6 9.5 6.8 8.1 0.6 9.5 6.5 165 0 165 165 1.4 0.1 1.6 0.9 12/09/2006 19:00:00 8.8 0.6 11.1 7.2 8.4 0.6 10.7 6.8 8.6 0.6 10.7 6.8 165 0 165 165 1.4 0 1.6 1.1 12/09/2006 19:10:00 12.3 0.9 14.5 9.1 11.8 0.8 13.7 8.8 11.9 1 14.1 8.4 165 0 165 165 1.4 0.1 1.6 0.9 12/09/2006 19:20:00 12.2 0.8 14.1 9.9 11.7 0.8 13.7 9.5 11.9 0.8 13.3 8.8 165 0 165 165 1.4 0.1 1.6 0.9 12/09/2006 19:30:00 9.6 0.9 11.5 7.2 9.2 0.8 10.7 7.2 9.4 0.9 11.1 7.2 165 0 165 165 1.4 0.1 1.6 0.9 12/09/2006 19:40:00 8 0.4 8.8 6.8 7.6 0.4 8.8 6.8 7.8 0.5 9.1 6.8 165 0 165 165 1.4 0 1.6 1.1 12/09/2006 19:50:00 9.9 1.2 12.6 7.6 9.5 1.1 12.2 7.2 9.6 1.2 13 7.2 165 0 165 165 1.4 0.1 1.8 1.1 12/09/2006 20:00:00 9.4 1 11.8 7.2 9.1 1 11.1 6.5 9.3 1 11.5 6.8 165 0 165 165 1.4 0 1.6 1.4 12/09/2006 20:10:00 8.1 0.8 10.7 5.7 7.7 0.8 10.3 5.7 7.8 0.8 9.9 5.3 165 0 165 165 1.4 0 1.6 1.1 12/09/2006 20:20:00 7.5 1 9.9 5.7 7.2 1 9.5 5.7 7.3 1 10.3 5.7 165 0 165 165 1.4 0 1.6 1.1 12/09/2006 20:30:00 9.3 0.7 11.5 6.5 9 0.7 11.5 5.7 9.1 0.8 11.1 6.5 165 0 165 165 1.4 0 1.6 1.4 12/09/2006 20:40:00 8.5 0.8 11.8 6.8 8.1 0.8 11.5 6.5 8.4 0.7 11.1 6.8 165 0 165 165 1.4 0 1.8 1.1 12/09/2006 20:50:00 8.2 0.6 9.5 6.5 7.9 0.6 9.5 6.1 8.1 0.6 9.5 6.5 165 0 165 165 1.4 0 1.8 1.1 12/09/2006 21:00:00 9.7 1.1 12.2 6.8 9.4 1.1 11.8 7.2 9.4 1 11.8 7.2 165 0 165 165 1.5 0 1.8 1.4 12/09/2006 21:10:00 10.5 0.9 12.6 7.2 10.1 0.9 11.8 7.2 10.2 0.9 11.8 7.2 165 0 165 165 1.5 0.1 1.8 0.9 12/09/2006 21:20:00 11.2 0.9 13.3 9.1 10.9 0.8 13 8.8 10.8 0.8 13 9.1 165 0 165 165 1.6 0.1 1.8 0.9 12/09/2006 21:30:00 10 1.5 12.6 5.3 9.8 1.3 12.2 5.7 9.9 1.3 11.8 6.1 165 0 165 165 1.6 0.1 2.3 1.4 12/09/2006 21:40:00 6.2 1.1 9.9 4.6 6.2 1.1 9.9 4.2 6.2 1.1 9.9 4.2 165 0 165 165 1.5 0 1.8 0.9 12/09/2006 21:50:00 8.4 0.9 10.3 6.1 8.2 0.8 9.9 6.1 8.4 0.9 10.3 6.5 165 0 165 165 1.4 0.1 1.6 0.9 12/09/2006 22:00:00 9.7 1.3 13 7.2 9.4 1.2 12.6 6.5 9.5 1.1 12.6 7.6 165 0 165 165 1.4 0 1.8 1.1 12/09/2006 22:10:00 8.9 0.7 11.1 6.5 8.7 0.7 10.7 6.1 8.8 0.7 11.1 6.8 165 0 165 165 1.5 0 1.8 1.4 12/09/2006 22:20:00 8.1 0.7 10.3 6.5 7.8 0.7 9.9 6.1 7.9 0.7 9.9 6.5 165 0 165 165 1.6 0 1.8 1.4 12/09/2006 22:30:00 8.4 0.9 11.1 6.1 8.2 0.9 10.7 5.7 8.3 1 11.1 6.1 165 0 165 165 1.5 0.2 1.8 0.9 12/09/2006 22:40:00 10.9 2.2 17.2 7.2 10.6 2.1 16.8 6.8 10.6 2.2 16.8 7.2 165 0 165 165 1.7 0.2 1.8 1.1 12/09/2006 22:50:00 12.9 1.5 17.6 9.9 12.5 1.4 17.2 9.5 12.5 1.4 17.9 9.9 165 0 165 165 1.4 0.1 1.6 0.9 12/09/2006 23:00:00 7.4 2.2 11.8 4.2 7.2 2.1 11.8 4.2 7.3 2.3 11.8 3.8 165 0 165 165 1.4 0.1 1.6 0.9 12/09/2006 23:10:00 8.2 1 11.1 5.3 8.1 1 11.1 4.9 7.9 1 11.1 5.3 165 0 165 165 1.4 0.1 1.6 0.9 12/09/2006 23:20:00 7.1 0.8 9.1 5.3 6.9 0.8 8.8 4.9 6.7 0.8 9.1 4.6 165 0 165 165 1.4 0 1.6 1.1 12/09/2006 23:30:00 7.5 0.7 9.1 5.7 7.3 0.7 9.1 5.3 7.2 0.7 8.8 5.3 165 0 165 165 1.4 0.1 1.6 1.1 12/09/2006 23:40:00 7.4 0.9 9.1 5.3 7.2 0.8 9.1 4.9 6.9 0.8 9.1 4.9 165 0 165 165 1.4 0 1.6 1.1 12/09/2006 23:50:00 6.8 0.8 8.8 4.9 6.6 0.7 8.8 4.9 6.5 0.7 8.8 4.6 165 0 165 165 1.4 0 1.8 1.4 12/10/2006 00:00:00 7.4 1.1 9.9 5.7 7.2 1.1 9.9 5.3 7.2 1.1 10.3 4.9 165 0 165 165 1.4 0 1.8 1.4 12/10/2006 00:10:00 7.3 1 10.3 4.9 7.2 1 9.9 4.9 7 1 9.9 4.9 165 0 165 165 1.4 0 1.8 0.9 12/10/2006 00:20:00 7.4 0.7 9.1 4.9 7.3 0.7 8.8 4.9 7.1 0.8 8.8 5.3 165 0 165 165 1.4 0.2 1.6 0.7 12/10/2006 00:30:00 5.8 0.6 7.6 4.6 5.6 0.5 7.2 4.6 5.6 0.6 7.6 3.8 165 0 165 165 1.3 0.1 1.6 0.9 12/10/2006 00:40:00 5 0.7 7.2 3.4 4.9 0.7 7.2 3.4 4.7 0.7 7.2 3 165 0 165 165 1.4 0.1 1.6 0.9 12/10/2006 00:50:00 5.5 0.6 6.8 4.2 5.4 0.5 6.8 4.2 5.5 0.6 6.8 4.2 165 0 165 165 1.4 0 1.6 1.1 12/10/2006 01:00:00 4.9 0.7 6.8 3.4 4.7 0.6 6.5 3.4 4.7 0.5 6.5 3.4 165 0 165 165 1.4 0 1.8 1.4 12/10/2006 01:10:00 4.4 0.4 5.7 3.4 4.3 0.4 5.3 3.4 4.3 0.4 5.7 3.4 165 0 165 165 1.4 0 1.6 1.1 12/10/2006 01:20:00 6.5 1.3 8.8 3.8 6.3 1.2 8.8 3.8 6.3 1.2 8.4 3.8 165 0 165 165 1.4 0.2 1.8 0.7 12/10/2006 01:30:00 8.2 0.8 9.9 6.1 7.9 0.8 9.9 6.1 8 0.7 9.9 5.7 165 0 165 165 1.2 0 1.4 1.1 12/10/2006 01:40:00 6.3 1.1 9.5 3.4 6.1 1.1 9.1 3.4 5.9 1.1 9.1 3 165 0 165 165 1.2 0 1.6 0.7 12/10/2006 01:50:00 5.6 0.9 7.6 3 5.4 0.8 7.2 3.4 5.3 0.9 7.6 3.8 165 0 165 165 1.2 0.1 1.6 0.7 12/10/2006 02:00:00 5.9 0.7 7.6 3.4 5.7 0.7 7.2 3.4 5.7 0.6 7.6 3.8 165 0 165 165 1.3 0 1.6 0.9 12/10/2006 02:10:00 5.7 0.6 6.8 4.6 5.6 0.5 6.8 4.6 5.5 0.5 6.8 4.2 165 0 165 165 1.2 0.1 1.6 0.7 12/10/2006 02:20:00 4.6 0.6 6.1 3.4 4.5 0.6 6.1 3 4.5 0.6 6.5 3.4 165 0 165 165 1.1 0 1.4 0.7 12/10/2006 02:30:00 4.6 0.5 5.7 3.4 4.4 0.5 5.3 3.4 4.4 0.5 5.7 3 165 0 165 165 1.1 0 1.4 0.7 12/10/2006 02:40:00 4.4 0.8 7.2 2.6 4.2 0.7 6.8 2.6 4 0.7 6.8 2.3 165 0 165 165 1.2 0 1.4 0.9 12/10/2006 02:50:00 3.7 0.5 5.3 2.6 3.5 0.5 5.7 2.3 3.4 0.5 5.3 2.3 165 0 165 165 1.3 0 1.6 0.9 12/10/2006 03:00:00 3.7 0.6 5.7 2.3 3.6 0.6 5.3 1.9 3.5 0.6 5.7 1.9 165 0 165 165 1.4 0 1.6 1.4 12/10/2006 03:10:00 5 0.7 6.5 3.4 4.9 0.7 6.5 3 4.8 0.6 6.1 3.4 165 0 165 165 1.4 0 1.8 0.9 12/10/2006 03:20:00 6.8 1.4 9.9 4.2 6.7 1.3 9.5 4.2 6.5 1.5 9.9 3.8 165 0 165 165 1.4 0.1 1.8 0.9 12/10/2006 03:30:00 8 0.7 9.5 6.1 7.7 0.7 9.1 6.1 7.7 0.7 9.5 6.1 165 0 165 165 1.3 0.1 1.6 0.9 12/10/2006 03:40:00 4.8 0.9 6.8 3 4.8 0.8 6.5 3 4.6 0.8 6.5 3 165 0 165 165 1.3 0 1.4 0.9 12/10/2006 03:50:00 4 0.6 5.3 2.3 4 0.5 5.3 2.6 3.7 0.5 4.9 2.3 165 0 165 165 1.2 0.1 1.6 0.7 12/10/2006 04:00:00 4.5 0.6 6.1 3.4 4.4 0.6 6.1 3 4 0.5 5.3 3 165 0 165 165 1.2 0.1 1.4 0.7 12/10/2006 04:10:00 3.5 0.5 4.9 1.9 3.6 0.5 4.9 2.3 3.2 0.5 4.6 1.9 165 0 165 165 1.2 0.1 1.4 0.7 12/10/2006 04:20:00 3.4 0.5 4.6 1.9 3.3 0.5 4.6 2.3 2.9 0.5 3.8 1.9 165 0 165 165 1.3 0.1 1.6 0.9 12/10/2006 04:30:00 4.3 0.5 5.7 3.4 4.2 0.6 5.7 3 4 0.8 5.3 2.6 165 0 165 165 1.4 0 1.6 1.1 12/10/2006 04:40:00 3.5 0.6 4.9 2.3 3.4 0.6 4.6 2.3 3.5 0.6 4.9 2.3 165 0 165 165 1.2 0.1 1.6 0.7 12/10/2006 04:50:00 3.3 0.4 4.2 2.3 3.3 0.4 4.2 2.3 3.1 0.3 4.2 2.3 165 0 165 165 1.2 0.1 1.4 0.7 12/10/2006 05:00:00 3.6 0.3 4.2 3 3.7 0.2 4.2 3 3.4 0.2 3.8 3 165 0 165 165 1.3 0 1.4 0.9 12/10/2006 05:10:00 3.3 0.4 4.2 1.9 3.4 0.4 4.2 2.3 3 0.3 3.8 1.9 165 0 165 165 1.4 0 1.6 1.1 12/10/2006 05:20:00 4 0.6 5.3 2.3 4 0.6 4.9 2.3 3.7 0.6 4.9 1.9 165 0 165 165 1.4 0 1.8 1.1 12/10/2006 05:30:00 3.6 0.7 5.3 1.5 3.5 0.7 5.3 1.5 3.4 0.7 4.9 1.1 165 0 165 165 1.4 0 1.6 1.4 12/10/2006 05:40:00 3 0.3 3.8 2.3 3 0.3 4.2 2.3 2.7 0.3 3.4 1.9 165 0 165 165 1.4 0 1.6 1.1 12/10/2006 05:50:00 3.2 0.5 4.2 2.3 3.2 0.4 4.2 1.9 2.9 0.5 3.8 1.9 165 0 165 165 1.4 0.1 1.6 0.9 12/10/2006 06:00:00 3.3 0.7 4.6 1.1 3.3 0.7 4.2 1.1 2.9 0.6 3.8 1.5 165 0 165 165 1.4 0.1 1.8 0.9 12/10/2006 06:10:00 4 0.5 4.9 2.6 3.9 0.4 4.6 2.6 3.4 0.5 4.2 2.3 165 0 165 165 1.4 0.1 1.6 0.9 12/10/2006 06:20:00 3.9 0.6 4.9 2.6 3.7 0.6 4.6 2.3 3.5 0.6 4.6 2.3 165 0 165 165 1.4 0.1 1.6 0.7 12/10/2006 06:30:00 3.6 0.4 4.9 2.6 3.6 0.4 4.6 2.6 3.3 0.4 4.6 2.3 165 0 165 165 1.4 0.1 1.6 0.9 12/10/2006 06:40:00 4.1 0.5 5.7 2.6 4 0.5 5.3 2.6 3.9 0.4 4.9 2.6 165 0 165 165 1.4 0.1 1.6 0.9 12/10/2006 06:50:00 3.9 0.7 5.3 2.3 3.8 0.7 5.3 2.3 3.8 0.6 5.3 2.3 165 0 165 165 1.4 0.1 1.8 0.9 12/10/2006 07:00:00 4.7 0.7 6.8 3 4.6 0.7 6.5 2.3 4.3 0.6 5.7 3 165 0 165 165 1.4 0.1 1.8 0.9 12/10/2006 07:10:00 4.9 0.6 6.1 3.8 4.9 0.6 6.5 3.4 4.8 0.5 6.1 3.4 165 0 165 165 1.4 0.1 1.8 0.9 12/10/2006 07:20:00 6 0.6 7.2 4.6 5.9 0.6 7.2 4.2 5.7 0.6 7.2 4.2 165 0 165 165 1.5 0 1.6 1.1 12/10/2006 07:30:00 7 0.6 8.8 5.3 6.9 0.6 8.8 5.3 6.9 0.6 8.8 4.9 165 0 165 165 1.5 0 1.8 0.9 12/10/2006 07:40:00 5.3 0.6 6.5 3.4 5.1 0.6 6.1 3 5.1 0.5 6.1 3.4 165 0 165 165 1.4 0.1 1.6 0.9 12/10/2006 07:50:00 3.3 0.6 4.9 2.3 3.2 0.6 4.6 1.9 3.3 0.6 4.9 2.3 165 0 165 165 1.4 0.1 1.8 0.9 12/10/2006 08:00:00 3.7 0.6 4.9 1.9 3.6 0.6 4.6 1.9 3.4 0.5 4.6 2.3 165 0 165 165 1.4 0.1 1.8 0.9 12/10/2006 08:10:00 3.6 0.7 4.9 1.5 3.6 0.7 4.9 1.1 3.6 0.6 4.9 1.9 165 0 165 165 1.4 0.1 1.8 0.9 12/10/2006 08:20:00 3.4 1.1 6.1 0.7 3.5 1.2 6.5 0.4 3.4 1 6.1 1.5 165 0 165 165 1.5 0 1.6 0.9 12/10/2006 08:30:00 5.5 0.6 7.2 4.2 5.6 0.6 7.2 4.2 5.4 0.6 6.5 3.8 165 0 165 165 1.5 0 1.8 0.9 12/10/2006 08:40:00 3.6 0.5 4.9 2.6 3.6 0.5 4.9 2.6 3.6 0.5 4.9 2.6 165 0 165 165 1.5 0 1.8 1.4 12/10/2006 08:50:00 5.7 1.8 9.1 2.6 5.7 1.9 9.1 3 5.5 1.8 9.1 2.6 165 0 165 165 1.5 0 1.8 1.4 12/10/2006 09:00:00 6.3 1.7 9.9 2.6 6.2 1.7 9.5 2.6 6.3 1.7 9.5 3.4 165 0 165 165 1.4 0 1.8 1.4 12/10/2006 09:10:00 3.1 1.3 5.7 1.1 3 1.3 5.7 1.1 3 1.4 6.5 0.4 165 0 165 165 1.4 0 1.6 1.4 12/10/2006 09:20:00 3.6 1 5.3 1.1 3.5 1 4.9 1.1 3.4 1 4.9 1.5 165 0 165 165 1.5 0 1.8 1.4 12/10/2006 09:30:00 4.8 0.7 6.1 3 4.6 0.7 6.1 2.6 4.8 0.7 6.1 3 165 0 165 165 1.5 0 1.8 1.4 12/10/2006 09:40:00 4.5 0.8 6.5 3 4.4 0.8 6.1 2.6 4.5 0.7 6.1 3 165 0 165 165 1.5 0 1.8 1.4 12/10/2006 09:50:00 3.2 0.6 5.3 1.9 3.2 0.6 4.9 1.5 3.4 0.5 4.9 2.3 165 0 165 165 1.5 0 1.8 1.4 12/10/2006 10:00:00 3.3 0.6 4.9 1.9 3.3 0.6 4.6 1.9 3.5 0.5 4.6 2.3 165 0 165 165 1.5 0 1.8 1.4 12/10/2006 10:10:00 2.8 0.5 4.2 1.5 2.7 0.5 4.2 1.1 2.8 0.5 4.2 1.5 165 0 165 165 1.5 0 1.8 1.4 12/10/2006 10:20:00 3 0.7 4.6 1.5 3 0.7 4.6 1.1 3 0.6 4.6 1.5 165 0 165 165 1.7 0 1.8 1.4 12/10/2006 10:30:00 3 0.6 4.2 1.9 3 0.6 4.2 1.5 2.9 0.6 4.6 1.5 165 0 165 165 1.7 0 1.8 1.4 12/10/2006 10:40:00 3.4 0.5 4.9 2.3 3.4 0.6 4.9 1.9 3.4 0.5 4.9 2.6 165 0 165 165 1.6 0 1.8 1.1 12/10/2006 10:50:00 4.8 0.8 6.8 3.4 4.9 0.8 7.2 3.8 4.7 0.8 6.8 3.4 166 2 165 165 1.7 0 1.8 1.1 12/10/2006 11:00:00 6.6 0.8 9.1 4.6 6.7 0.9 9.1 4.9 6.5 0.9 9.1 4.2 169 19 169 165 1.8 0 1.8 1.4 12/10/2006 11:10:00 8.5 1.4 12.2 5.7 8.6 1.3 11.5 5.3 8.3 1.3 11.5 5.7 156 13 134 165 1.7 0 1.8 1.4 12/10/2006 11:20:00 9.1 0.8 10.7 6.5 9.4 0.7 10.7 6.8 9.7 1.2 13.3 6.8 131 6 133 165 1.8 0.1 1.8 1.4 12/10/2006 11:30:00 8.4 0.7 9.5 6.1 9.2 0.9 11.1 6.8 9.2 1 11.8 5.3 129 7 133 165 1.7 0.1 1.8 0.9 12/10/2006 11:40:00 7.5 0.9 9.1 5.3 8.4 1 10.7 5.7 8.2 1.1 10.7 5.7 124 3 114 165 1.4 0 1.6 1.4 12/10/2006 11:50:00 5.1 1 8.8 3 5.8 1.1 9.1 3.8 5.5 1.2 8.8 3.4 123 0 124 165 1.4 0 1.6 1.4 12/10/2006 12:00:00 4.8 1 6.5 2.3 5.6 1.1 7.2 2.6 5.1 1.2 7.2 2.3 123 0 124 165 1.4 0.1 1.6 0.9 12/10/2006 12:10:00 5.8 0.2 6.5 5.3 6.5 0.3 7.2 5.3 6.2 0.4 7.2 4.2 123 0 124 165 1.4 0.1 1.6 0.9 12/10/2006 12:20:00 5.2 0.4 6.1 3.8 5.8 0.5 6.8 4.2 5.4 0.7 6.8 2.3 123 0 124 165 1.4 0.1 1.6 0.7 12/10/2006 12:30:00 4.8 0.4 5.7 4.2 5.4 0.4 6.5 4.6 5.1 0.4 6.1 3.8 123 0 123 165 1.3 0.1 1.6 0.7 12/10/2006 12:40:00 4.4 0.4 5.3 2.6 5.1 0.5 6.1 3.4 4.7 0.6 5.7 3 123 0 124 165 1.2 0.1 1.6 0.7 12/10/2006 12:50:00 4.3 0.5 6.1 2.6 5 0.6 6.8 3.4 4.4 0.6 6.8 3 123 0 123 165 1.1 0 1.4 0.4 12/10/2006 13:00:00 5.1 0.5 6.8 3.8 5.9 0.6 7.6 3.8 5.2 0.6 6.8 3.8 123 0 124 165 1.2 0 1.4 0.9 12/10/2006 13:10:00 6.8 0.6 8.4 5.3 7.6 0.7 9.5 5.3 7.1 0.8 9.1 4.9 123 0 123 165 1.4 0 1.6 1.4 12/10/2006 13:20:00 7.1 0.6 8.8 5.3 7.9 0.7 9.9 6.1 7.3 0.8 9.9 5.3 123 0 123 165 1.4 0 1.6 1.4 12/10/2006 13:30:00 6.9 0.8 8.8 4.9 7.6 0.9 9.5 5.3 7.2 1 9.9 4.6 123 0 124 165 1.4 0 1.6 1.4 12/10/2006 13:40:00 6.8 0.6 8.4 5.3 7.6 0.6 8.8 6.1 7.1 0.7 9.1 4.9 123 0 123 165 1.4 0 1.6 1.4 12/10/2006 13:50:00 5.5 0.4 6.5 4.6 6.1 0.4 7.2 4.9 5.8 0.5 7.2 4.2 123 0 123 165 1.4 0 1.6 1.4 12/10/2006 14:00:00 4.7 0.4 5.7 3.4 5.3 0.4 6.5 3.4 5.1 0.5 6.1 3 123 0 123 165 1.4 0 1.6 1.4 12/10/2006 14:10:00 5 0.7 6.5 3 5.7 0.8 7.2 3.4 5 0.9 6.8 3 123 0 123 165 1.4 0 1.6 1.4 12/10/2006 14:20:00 5 0.7 7.2 3.4 5.7 0.7 7.6 4.2 5.1 0.7 6.8 3 123 0 123 165 1.4 0.1 1.6 0.9 12/10/2006 14:30:00 4.6 0.7 6.1 2.3 5.1 0.7 6.5 2.6 4.5 0.7 6.5 2.6 123 0 123 165 1.4 0.1 1.8 0.9 12/10/2006 14:40:00 6.6 1.2 8.8 3.8 7 1.3 9.5 3.4 6.6 1.3 9.1 3.4 124 0 123 165 1.4 0.1 1.6 0.9 12/10/2006 14:50:00 5.9 1 8.8 4.2 6.4 1 9.9 4.6 6 1.1 9.1 3.8 123 0 123 165 1.5 0.1 1.6 0.9 12/10/2006 15:00:00 8.5 1.1 10.7 6.5 9.5 1.3 12.6 6.8 8.8 1.2 11.8 5.7 120 3 121 165 1.5 0 1.6 0.9 12/10/2006 15:10:00 9 1.3 13.7 5.3 10.6 2 15.6 6.1 9.9 2 14.9 5.7 107 6 112 165 1.6 0 1.8 1.4 12/10/2006 15:20:00 10.2 1.6 14.5 6.8 12 1.6 15.3 7.6 11.4 1.7 14.9 6.8 115 6 117 165 2.1 0.2 2.6 1.6 12/10/2006 15:30:00 12.3 1.6 17.2 9.5 12.1 1.7 17.6 9.5 12.1 1.7 16.4 8.8 134 13 120 165 2.2 0.2 2.6 1.6 12/10/2006 15:40:00 10.1 1.3 13 6.5 9.7 1.2 12.6 6.1 10 1.5 13 6.5 161 4 162 165 1.4 0 1.6 1.4 12/10/2006 15:50:00 7.3 2.5 12.6 3 7.1 2.4 11.8 3 6.9 2.5 11.5 2.6 163 0 162 165 1.4 0 1.6 0.9 12/10/2006 16:00:00 5.7 1.3 8.8 3.4 5.7 1.3 8.8 3.4 5.3 1.4 8.4 2.6 162 1 162 165 1.5 0 1.6 1.1 12/10/2006 16:10:00 8.3 1.7 12.6 4.2 8.5 1.8 12.6 4.2 7.6 1.7 12.2 4.2 132 22 102 165 1.5 0 1.8 1.4 12/10/2006 16:20:00 12.1 1.4 15.3 8.8 12.3 1.5 15.6 8.8 11.4 1.5 15.3 6.8 109 5 99 165 2.3 0.3 2.8 1.4 12/10/2006 16:30:00 13 1.2 15.3 9.1 13.4 1.3 16.1 9.1 12.5 1.2 15.3 8.4 104 5 98 165 2.9 0 3.3 2.8 12/10/2006 16:40:00 12.4 1.2 14.5 7.6 12.8 1.3 15.6 7.6 11.7 1.3 14.5 7.6 107 5 110 165 3 0 3.3 2.6 12/10/2006 16:50:00 11.7 1.5 15.6 8.4 12 1.5 16.1 8.4 10.9 1.7 15.6 7.2 112 7 104 165 2.9 0.1 3.3 2.6 12/10/2006 17:00:00 11.9 1.2 14.5 8 12.2 1.3 15.3 8.4 11.1 1.4 14.5 7.6 104 6 105 165 2.9 0.1 3.3 2.3 12/10/2006 17:10:00 11.1 1.3 14.1 7.6 11.4 1.3 14.5 7.6 10.4 1.5 13.7 6.5 102 6 99 165 2.9 0.2 3.3 2.3 12/10/2006 17:20:00 11.6 1.2 14.9 8.4 12 1.3 14.9 8.4 10.8 1.5 14.1 7.2 105 6 115 165 3 0.1 3.3 2.6 12/10/2006 17:30:00 12 1.2 15.3 8 12.2 1.3 15.6 8.8 11.2 1.4 14.5 7.2 108 6 108 165 2.9 0.1 3.3 2.3 12/10/2006 17:40:00 11.6 1.5 14.5 7.6 11.9 1.6 15.3 7.2 11.1 1.7 14.1 6.1 106 6 111 165 2.9 0 3 2.6 12/10/2006 17:50:00 11.8 1.2 14.5 9.1 12.1 1.2 14.9 9.1 11 1.5 14.9 6.8 112 6 123 165 2.9 0 3 2.8 12/10/2006 18:00:00 11.9 1.1 14.5 8 12.2 1.1 14.9 8 11.3 1.3 14.1 7.2 112 5 112 165 2.7 0 3 2.6 12/10/2006 18:10:00 10.1 1 12.6 6.5 10.3 1 13 7.2 9.4 1.2 13 6.1 107 6 108 165 2.9 0 3 2.6 12/10/2006 18:20:00 9.8 1 11.8 6.8 10 1 12.6 7.2 9.1 1.2 11.8 6.1 104 7 98 165 2.9 0.1 3.3 2.6 12/10/2006 18:30:00 9.9 1.1 12.6 7.2 10.2 1.1 13 7.6 9.4 1.3 12.6 5.7 107 6 103 165 2.9 0.1 3.3 2.6 12/10/2006 18:40:00 10.4 1.2 13 6.8 10.6 1.2 13.3 6.8 9.7 1.3 12.6 6.1 102 7 100 165 2.9 0.1 3.3 2.6 12/10/2006 18:50:00 10.2 1 13 6.8 10.4 1 13.3 7.2 9.5 1 12.6 6.8 102 6 112 165 2.9 0.1 3.3 2.6 12/10/2006 19:00:00 9.4 1 11.8 6.5 9.6 1 12.2 7.2 8.7 1.2 11.5 5.3 105 7 107 165 2.9 0.2 3.3 2.6 12/10/2006 19:10:00 9.8 1 12.2 6.8 10 1 12.2 6.8 8.9 1.1 11.5 5.7 100 6 108 165 2.9 0.1 3.3 2.6 12/10/2006 19:20:00 9.7 1 11.8 6.5 10 1 12.2 6.5 9.1 1.1 11.5 6.5 96 6 99 165 3 0.1 3.3 2.6 12/10/2006 19:30:00 9.3 1 11.8 6.1 9.5 1 12.2 6.5 8.7 1 11.1 5.7 94 7 95 165 3 0.1 3.3 2.8 12/10/2006 19:40:00 10.3 1.5 13.7 5.7 10.6 1.5 14.1 6.5 9.7 1.5 13.3 6.1 94 9 103 165 2.9 0.1 3.3 2.6 12/10/2006 19:50:00 10.1 1 12.6 6.8 10.4 1 12.6 7.6 9.4 1.1 12.2 6.5 100 6 101 165 2.9 0.2 3.3 2.6 12/10/2006 20:00:00 9.2 0.9 11.1 6.5 9.5 0.9 11.5 6.5 8.7 0.9 11.1 5.7 99 6 109 165 2.9 0.1 3.3 2.6 12/10/2006 20:10:00 11.3 1.2 14.1 7.6 11.6 1.2 14.5 8 10.7 1.4 14.1 6.8 108 7 114 165 2.7 0.2 3.3 2.1 12/10/2006 20:20:00 10 1.7 14.5 6.8 10.2 1.7 14.9 6.5 9.4 1.9 14.9 5.7 105 8 106 165 2.1 0.1 2.6 1.6 12/10/2006 20:30:00 9 1 11.5 6.8 9.3 1 11.8 6.8 8.3 1.1 11.8 5.3 95 6 103 165 2.6 0.1 3 2.1 12/10/2006 20:40:00 8.9 1.3 12.2 5.7 9.1 1.4 13 5.7 8.3 1.3 11.5 5.3 97 9 96 165 2.9 0.1 3 2.6 12/10/2006 20:50:00 9.8 1.1 12.2 7.6 10.1 1.1 12.6 7.2 9.4 1.1 12.2 6.5 90 7 91 165 2.9 0 3.3 2.6 12/10/2006 21:00:00 9.7 0.8 11.8 7.2 10 0.9 12.2 7.2 9.3 0.9 11.5 6.8 90 5 87 165 2.9 0 3 2.6 12/10/2006 21:10:00 9.5 1.1 12.6 6.8 9.7 1.1 13 7.2 8.9 1 11.5 6.5 92 7 87 165 2.9 0 3 2.6 12/10/2006 21:20:00 9.1 0.9 11.5 6.5 9.3 1 11.5 6.8 8.6 1 11.1 6.5 91 6 94 165 2.8 0.1 3.3 2.3 12/10/2006 21:30:00 9.2 1.1 12.2 6.5 9.5 1.1 12.6 6.5 8.6 1 11.8 6.1 92 7 92 165 2.7 0 3 2.3 12/10/2006 21:40:00 10.3 1.2 12.6 6.1 10.6 1.2 13.3 6.5 9.8 1.1 12.2 6.1 85 8 78 165 2.8 0.2 3.3 2.1 12/10/2006 21:50:00 8.9 1.2 12.6 6.5 9.1 1.2 12.6 6.1 8.5 1.1 11.8 6.1 75 7 81 165 3 0 3.3 2.6 12/10/2006 22:00:00 8.4 1 10.7 5.7 8.6 1.1 11.1 5.7 8 1.1 10.7 5.3 73 7 73 165 3 0 3.3 2.8 12/10/2006 22:10:00 7.6 1 10.3 4.9 7.7 1 10.3 4.9 7.2 1 9.9 4.9 66 8 66 165 2.9 0.1 3.3 2.6 12/10/2006 22:20:00 7.1 1 9.9 4.9 7.2 1.1 9.9 4.9 6.8 1 9.9 4.2 68 9 70 165 3 0 3.3 2.8 12/10/2006 22:30:00 7.2 1.2 9.5 3.8 7.2 1.2 10.3 3.8 6.8 1.2 9.1 3 61 8 63 165 3 0.1 3.3 2.8 12/10/2006 22:40:00 7.2 1.2 9.9 4.6 7.3 1.2 10.3 4.6 6.8 1 9.9 3.8 60 10 52 165 3 0 3.3 2.8 12/10/2006 22:50:00 7.1 1.5 13 4.2 7.2 1.5 13.3 4.2 6.8 1.3 11.5 4.6 59 19 123 165 3 0 3.3 2.8 12/10/2006 23:00:00 8.6 1.5 12.2 5.7 8.8 1.5 13 5.7 8.2 1.4 13.3 5.3 101 11 109 165 2 0.4 3 1.6 12/10/2006 23:10:00 8.7 1.7 12.2 4.6 8.8 1.8 12.6 4.2 8 1.6 11.8 4.2 90 9 77 165 2 0.2 2.6 1.6 12/10/2006 23:20:00 8.7 1.4 12.6 4.6 8.9 1.5 12.6 4.2 8.3 1.4 12.6 4.9 68 8 76 165 2.6 0.1 2.8 2.1 12/10/2006 23:30:00 7.5 1.2 10.7 4.6 7.6 1.2 11.1 4.2 7 1.1 10.7 4.9 57 9 53 165 2.7 0.2 3.3 2.3 12/10/2006 23:40:00 7.7 1.9 12.2 4.2 7.9 1.9 12.6 3.8 7.4 1.9 11.5 3.8 60 9 66 165 2.7 0.1 3 2.3 12/10/2006 23:50:00 8 1.4 11.1 4.2 8.2 1.5 11.1 4.2 7.6 1.3 10.7 4.2 61 9 52 165 2.6 0.1 2.8 2.3 12/11/2006 00:00:00 7.3 1 9.9 4.6 7.4 1 10.3 4.9 7 0.9 9.9 4.6 66 8 76 165 2.5 0.2 3 1.8 12/11/2006 00:10:00 7.2 1 9.9 4.6 7.3 1 10.3 4.9 7 1 9.9 4.9 67 8 64 165 2.7 0.2 3 1.8 12/11/2006 00:20:00 6.5 1.1 9.5 3.8 6.6 1.2 9.9 3.8 6.2 1.2 9.9 3.8 64 9 72 165 2.5 0.2 2.8 1.8 12/11/2006 00:30:00 6.9 1.3 9.5 3.8 6.9 1.4 9.9 3.8 6.5 1.3 9.5 3.8 67 11 78 165 2.4 0.2 2.8 1.8 12/11/2006 00:40:00 6.9 1.2 9.1 4.2 7 1.2 9.5 4.2 6.7 1.1 9.1 3.4 64 11 81 165 2.2 0 2.6 1.6 12/11/2006 00:50:00 6.6 1.3 9.5 3.8 6.7 1.4 9.9 3.4 6.2 1.2 8.8 3.4 65 9 73 165 2.3 0 2.3 1.8 12/11/2006 01:00:00 6.5 1 8.8 4.2 6.5 1.1 9.1 3.8 6.1 0.9 8.8 4.2 59 8 70 165 2.3 0 2.6 1.8 12/11/2006 01:10:00 6.1 0.7 8 3.8 6.2 0.6 8 3.8 5.8 0.7 7.2 3.8 46 7 46 165 2.2 0 2.6 1.8 12/11/2006 01:20:00 6.5 0.6 8 4.6 6.6 0.6 8 4.6 6.1 0.6 8 4.2 43 5 52 165 2.3 0.2 2.6 1.8 12/11/2006 01:30:00 5.9 0.8 7.6 4.2 5.9 0.8 7.6 4.2 5.7 0.7 7.2 3.4 39 7 45 165 2.4 0.1 2.8 2.1 12/11/2006 01:40:00 6.1 1 8.8 4.2 6.2 1 8.8 4.2 5.9 1 8.8 3.8 36 6 38 165 2.6 0 2.8 2.3 12/11/2006 01:50:00 7.3 0.8 9.1 5.3 7.4 0.8 9.1 5.3 6.8 0.8 9.1 4.9 42 6 34 165 2.9 0 3 2.6 12/11/2006 02:00:00 7 1.1 10.7 3.8 7 1.1 10.7 3.8 6.4 1 10.3 3.4 46 7 43 165 2.9 0 3 2.8 12/11/2006 02:10:00 7.2 0.8 9.5 4.9 7.2 0.8 9.1 4.9 6.7 0.8 8.8 4.6 43 8 43 165 2.9 0 3.3 2.8 12/11/2006 02:20:00 6.6 1.1 9.5 4.2 6.6 1.1 9.5 4.2 6.2 1 8.4 3.8 48 9 53 165 2.9 0 3 2.8 12/11/2006 02:30:00 7.3 1 9.9 4.6 7.3 1 9.9 4.6 6.9 1 9.1 4.6 42 8 53 165 2.9 0 3 2.8 12/11/2006 02:40:00 7.3 1.1 10.3 4.9 7.4 1 10.3 4.9 7.1 1 9.5 4.6 42 9 37 165 3 0 3.3 2.8 12/11/2006 02:50:00 7.1 1.1 10.7 3.8 7.2 1.1 10.7 4.6 6.7 1.1 10.3 3.8 48 15 53 165 2.7 0.2 3 2.1 12/11/2006 03:00:00 8.6 1.6 12.6 4.6 8.6 1.7 12.6 4.9 8.1 1.6 13 4.2 45 11 40 165 2.8 0 3 2.6 12/11/2006 03:10:00 7.7 1.1 10.3 5.3 7.8 1.2 10.7 5.3 7.3 1.1 10.7 4.2 57 9 78 165 2.8 0 3 2.6 12/11/2006 03:20:00 6.7 1.1 10.3 4.2 6.7 1.2 10.3 3.8 6.4 1.1 9.1 3.8 50 9 52 165 2.7 0 3 2.6 12/11/2006 03:30:00 7.2 1.2 9.9 4.6 7.1 1.2 10.3 4.2 6.7 1.1 9.9 4.2 45 8 48 165 2.7 0 2.8 2.3 12/11/2006 03:40:00 7.1 1 9.5 4.2 7 1.1 9.5 3.8 6.6 1 9.5 4.2 43 9 39 165 2.7 0 3 2.3 12/11/2006 03:50:00 8.5 0.8 10.7 6.5 8.5 0.9 10.7 6.5 8.1 0.9 10.3 5.7 41 7 38 165 2.9 0 3 2.6 12/11/2006 04:00:00 8.1 0.9 9.9 5.7 8 0.9 10.3 5.7 7.7 1 9.9 4.9 42 6 43 165 2.9 0 3 2.8 12/11/2006 04:10:00 8.1 0.8 10.3 5.3 8.1 0.9 10.7 5.3 7.7 1 10.7 5.3 38 8 33 165 2.9 0 3 2.8 12/11/2006 04:20:00 8.5 1.1 11.1 5.3 8.5 1.3 11.5 5.3 8.1 1.3 10.7 4.9 53 8 58 165 2.6 0.2 3 1.8 12/11/2006 04:30:00 7.3 1.2 10.3 4.2 7.3 1.2 10.7 3.8 6.7 1.1 10.3 3.8 51 9 46 165 2.4 0.2 2.8 1.8 12/11/2006 04:40:00 6.4 0.9 8.8 3.8 6.3 1 9.1 3.8 6.1 0.8 8.8 4.2 46 8 57 165 2.3 0.2 2.8 1.8 12/11/2006 04:50:00 6.6 0.9 8.4 4.6 6.5 1 8.4 4.2 6.3 0.9 8.4 4.2 38 6 42 165 2.4 0.2 2.6 1.8 12/11/2006 05:00:00 6.7 0.9 8.4 4.2 6.7 0.9 8.4 3.8 6.5 0.8 8 4.6 36 4 36 165 2.4 0.2 2.6 1.8 12/11/2006 05:10:00 6.2 0.8 8.4 4.2 6.1 0.9 8 4.2 6 0.8 8.4 4.2 32 7 40 165 2.3 0.2 2.6 1.8 12/11/2006 05:20:00 7.6 0.8 9.5 4.9 7.6 0.8 9.5 4.6 7.4 0.8 9.9 4.9 34 6 33 165 2.3 0.1 2.6 1.8 12/11/2006 05:30:00 7.4 0.7 9.1 4.6 7.5 0.7 9.1 4.6 7.2 0.8 9.1 4.9 38 4 44 165 2.3 0.2 2.8 1.8 12/11/2006 05:40:00 6 0.9 8 3.8 6 0.9 8 3.8 5.7 0.8 7.6 3.4 30 9 23 165 2.4 0.1 2.8 1.8 12/11/2006 05:50:00 6.9 1.1 9.9 4.6 7 1.1 10.3 4.6 6.7 1 10.3 4.6 54 12 64 165 2.3 0.2 2.8 1.8 12/11/2006 06:00:00 6.8 0.8 8.8 4.6 6.7 0.8 8.8 4.6 6.6 0.8 9.1 4.2 38 6 38 165 2 0 2.6 1.4 12/11/2006 06:10:00 6.8 0.6 8 4.9 6.7 0.6 8 4.6 6.6 0.6 8 4.6 26 6 31 165 2 0 2.3 1.4 12/11/2006 06:20:00 6 0.4 6.8 4.9 5.6 0.5 6.8 3.4 6.1 0.5 7.2 4.6 18 3 16 165 2 0.1 2.3 1.6 12/11/2006 06:30:00 6.2 1 8.4 4.6 5.9 1 8.8 3.8 6.1 0.9 8.8 3.8 24 9 23 165 2 0.1 2.3 1.4 12/11/2006 06:40:00 6.6 1.1 9.1 4.2 6.5 1.1 9.1 3.8 6.5 1 9.1 3.8 26 7 28 165 2 0.2 2.3 1.4 12/11/2006 06:50:00 5.2 0.7 7.2 3.4 5 0.8 7.2 3 5 0.7 7.6 3.8 24 8 41 165 2 0.1 2.3 1.6 12/11/2006 07:00:00 5.3 1 8 2.6 5.1 1 8 2.6 5.1 0.9 8.4 3.4 27 10 25 165 2.1 0.1 2.6 1.6 12/11/2006 07:10:00 7.5 1.5 11.5 4.9 6.9 1.7 11.1 3.4 7.3 1.5 10.7 4.6 18 8 35 165 2.1 0 2.6 1.6 12/11/2006 07:20:00 7.5 1.3 10.7 4.6 7.2 1.4 10.7 4.2 7.4 1.2 10.7 4.6 23 7 29 165 2.2 0.1 2.6 1.8 12/11/2006 07:30:00 6.8 1.1 9.9 4.6 6.6 1.2 10.3 3.8 6.5 1 9.9 4.2 23 8 33 165 2.2 0.2 2.6 1.8 12/11/2006 07:40:00 7.5 0.9 9.5 4.6 6.9 1 9.1 3.8 7 0.9 9.1 4.6 18 9 27 165 2.2 0.1 2.6 1.8 12/11/2006 07:50:00 8.3 1 10.7 5.7 6.8 1.3 9.9 3.8 7.9 1.1 10.7 4.6 11 7 6 165 2.1 0.1 2.6 1.6 12/11/2006 08:00:00 7.9 1 10.3 4.9 6.7 1.1 9.5 4.2 7.8 1 9.9 5.3 13 7 10 165 2.1 0.2 2.6 1.8 12/11/2006 08:10:00 7.3 1.1 9.9 4.2 6.7 1.2 9.5 3.8 7.2 1.1 9.9 4.9 17 9 19 165 2.2 0.2 2.6 1.8 12/11/2006 08:20:00 8.8 1.5 13 5.3 8.4 1.8 13 3.4 8.4 1.6 13 5.3 23 9 28 165 2.3 0.1 2.6 1.8 12/11/2006 08:30:00 9.3 1.3 12.2 6.5 8.4 1.9 12.6 3.8 9 1.3 11.8 6.1 16 8 32 165 2.2 0.1 2.6 1.8 12/11/2006 08:40:00 7.9 0.9 9.9 6.1 7 1.1 9.9 4.2 7.7 0.9 9.9 5.3 16 6 23 165 2.1 0.2 2.6 1.8 12/11/2006 08:50:00 8.2 0.9 10.3 6.1 7.1 1.2 9.9 4.2 7.7 0.9 10.3 5.7 14 7 18 165 2.1 0.2 2.6 1.8 12/11/2006 09:00:00 9.3 1 12.6 6.5 7.7 1.2 11.8 4.2 9 1.2 12.2 6.5 12 6 15 165 2.2 0.2 2.6 1.8 12/11/2006 09:10:00 9.2 0.9 12.2 6.5 7.9 1.3 11.1 4.2 9.1 1 11.5 6.8 13 7 11 165 2.3 0.1 2.6 2.1 12/11/2006 09:20:00 8.2 1.3 11.5 4.9 7.5 1.5 11.5 4.2 8.1 1.4 11.8 4.6 18 8 23 165 2.4 0 2.6 2.3 12/11/2006 09:30:00 8 1.3 10.7 4.9 7.6 1.5 11.1 4.6 7.7 1.3 10.7 4.9 21 8 20 165 2.4 0.1 2.6 1.8 12/11/2006 09:40:00 6.5 1 8.8 4.2 6 1.1 8.8 3.8 6.3 1 9.1 3.8 19 8 21 165 2.4 0 2.8 2.3 12/11/2006 09:50:00 7.1 1.2 9.9 3.8 6.8 1.3 9.9 2.6 6.8 1.1 9.9 4.2 24 9 20 165 2.4 0 2.6 2.3 12/11/2006 10:00:00 6 1.6 9.5 3.8 5.8 1.7 9.5 3 5.7 1.5 9.1 3 22 8 29 165 2.4 0 2.6 2.3 12/11/2006 10:10:00 7.8 1.3 10.7 4.2 6.9 1.6 10.7 2.3 7.3 1.5 10.7 3.8 16 9 26 165 2.4 0.1 2.6 2.1 12/11/2006 10:20:00 7.2 0.8 9.1 4.6 6.3 1.1 8.4 2.6 7 0.8 8.8 4.9 15 7 19 165 2.2 0.1 2.6 1.8 12/11/2006 10:30:00 8.6 1.1 11.1 6.5 6.9 1.2 9.9 3.4 8.4 1.1 10.7 5.7 13 6 16 165 2.1 0.1 2.3 1.6 12/11/2006 10:40:00 10.6 1 13 7.6 7.3 1.4 10.7 4.6 10.6 1.1 13.7 7.2 7 6 12 165 2.3 0.1 2.6 1.8 12/11/2006 10:50:00 9.1 1 12.2 6.5 6.5 1.5 11.5 3.4 9.1 1 12.2 6.1 9 6 15 165 2.4 0.1 2.6 2.1 12/11/2006 11:00:00 7.7 1.1 11.5 5.3 5.8 1.3 9.5 3 7.4 1.1 10.7 4.9 10 7 11 165 2.4 0 2.6 2.1 12/11/2006 11:10:00 8.1 1.2 11.1 5.3 5.8 1.5 10.3 3 7.7 1.2 11.1 4.9 3 8 5 165 2.4 0 2.6 2.1 12/11/2006 11:20:00 9.3 1 12.6 7.2 7 1.8 11.5 3.8 9 1 11.8 6.1 356 6 354 165 2.4 0 2.8 2.3 12/11/2006 11:30:00 8.1 1 10.7 4.9 6.4 1.7 9.9 3 8 0.8 9.9 5.7 355 6 5 165 2.5 0 2.8 2.3 12/11/2006 11:40:00 8.6 1.1 11.5 5.7 7 1.5 11.5 3 8.3 1.1 11.1 5.7 354 8 0 165 2.6 0 2.8 2.3 12/11/2006 11:50:00 7.4 1 9.9 5.7 7 1.2 9.9 3.8 7 0.9 9.5 4.9 348 7 349 165 2.5 0 2.8 2.3 12/11/2006 12:00:00 7.8 0.9 10.3 5.7 7.7 1 10.7 4.6 7.6 1 9.9 4.9 340 10 341 165 2.6 0 2.8 2.6 12/11/2006 12:10:00 7.3 1.2 10.7 3.8 7.2 1.4 10.3 3 7.2 1.1 10.7 4.2 342 9 336 165 2.6 0 2.8 2.6 12/11/2006 12:20:00 7.4 1 10.7 5.3 7.2 1.1 11.5 4.2 7.2 0.9 9.9 4.2 345 7 342 165 2.7 0 2.8 2.6 12/11/2006 12:30:00 6.7 1.3 9.5 4.2 6.5 1.3 9.9 3.8 6.5 1.3 10.3 3.8 339 10 335 165 2.7 0 2.8 2.6 12/11/2006 12:40:00 6.3 1.1 10.7 3.8 6.1 1.1 10.7 3.4 5.9 1.1 9.9 3.8 337 10 335 165 2.8 0 3 2.3 12/11/2006 12:50:00 6.6 1 9.1 4.2 6.5 1.1 8.8 3.8 6.1 1 8.4 3.8 338 9 331 165 2.8 0 3 2.6 12/11/2006 13:00:00 7.4 1.2 11.1 4.6 7.3 1.2 11.1 4.2 7 1.1 9.9 4.2 339 9 344 165 2.9 0 3 2.6 12/11/2006 13:10:00 8.7 1.1 11.8 5.7 8.6 1.1 11.5 5.7 8.4 1.2 11.1 5.3 336 8 334 165 2.9 0 3 2.8 12/11/2006 13:20:00 9 1 11.5 6.1 8.9 1 11.5 6.1 8.9 1 11.1 6.1 336 9 337 165 3 0 3.3 2.8 12/11/2006 13:30:00 8.2 1.1 10.7 5.7 8 1 10.3 5.7 7.6 1 10.3 4.9 335 8 333 165 3.2 0 3.3 3 12/11/2006 13:40:00 7 1.4 9.5 4.2 6.8 1.4 9.5 3 6.5 1.3 9.5 3.4 337 10 327 165 3.1 0 3.5 2.8 12/11/2006 13:50:00 7.5 1.3 11.1 4.2 7.2 1.5 10.7 3.8 6.7 1.5 10.3 3.4 336 11 340 165 3 0 3.3 2.8 12/11/2006 14:00:00 8.2 1.1 10.7 5.7 8 1 10.7 5.3 7.8 1.1 11.1 4.9 335 8 336 165 3 0.1 3.3 2.3 12/11/2006 14:10:00 8.2 1.1 10.3 4.9 8 1.1 10.3 4.9 7.8 1 9.9 5.3 333 7 337 165 2.9 0 3.3 2.8 12/11/2006 14:20:00 7.7 1.1 10.3 4.9 7.6 1.1 10.7 4.9 7.6 1.1 10.7 4.6 334 8 323 165 2.8 0 3 2.3 12/11/2006 14:30:00 7.5 1.1 10.3 4.6 7.3 1.1 9.9 4.2 7.1 1 10.3 4.6 335 8 338 165 2.8 0 3 2.6 12/11/2006 14:40:00 6.7 1 9.5 4.2 6.4 1.1 9.1 3 6 1 8.8 3.4 334 10 328 165 2.8 0 3 2.6 12/11/2006 14:50:00 5.5 1 7.6 3.4 5.2 1 7.6 3 5 0.9 7.2 3 335 15 340 165 2.8 0 3 2.6 12/11/2006 15:00:00 5.6 1 8.4 3.4 5.5 1 8 2.6 5.4 0.9 7.2 3 337 11 343 165 2.9 0 3 2.6 12/11/2006 15:10:00 4.7 1 6.8 2.3 4.6 1.1 6.8 1.5 4.3 1 6.5 1.9 332 12 321 165 2.9 0 3 2.6 12/11/2006 15:20:00 4.6 0.7 6.5 2.6 4.4 0.7 6.5 2.3 3.7 0.6 5.7 2.3 318 11 321 165 2.5 0.1 3 2.3 12/11/2006 15:30:00 4.8 1.3 8.8 2.3 4.6 1.3 8.4 2.3 4.2 1.3 7.6 1.5 329 13 336 165 2.4 0.2 2.8 1.8 12/11/2006 15:40:00 5.6 1 9.1 3.8 5.5 1.1 9.1 3.4 5.1 1 8 3 321 13 349 165 2.5 0.1 2.8 2.3 12/11/2006 15:50:00 5.1 0.8 7.6 3 5 0.9 7.2 2.3 5 0.8 7.2 2.6 322 8 339 165 2.5 0 2.8 2.3 12/11/2006 16:00:00 4.8 0.9 6.8 2.6 4.6 0.9 6.8 2.3 4.2 0.9 6.5 1.9 315 12 356 165 2.4 0 2.6 2.1 12/11/2006 16:10:00 5.8 0.8 7.6 3.8 5.7 0.8 7.6 3.8 4.8 0.7 6.5 2.6 309 11 314 165 2 0.2 2.6 1.4 12/11/2006 16:20:00 6.6 1.2 9.1 3.8 6.6 1.2 9.1 3.4 5.5 1.2 8.8 2.6 296 11 292 165 1.9 0.1 2.3 1.4 12/11/2006 16:30:00 6.9 1.1 9.5 4.6 6.9 1.1 9.5 4.6 5.6 1.2 9.5 3 298 8 292 165 1.8 0 1.8 1.6 12/11/2006 16:40:00 6 1 8.8 3.4 6 1.1 8.8 3.4 5 1.2 8 2.6 295 12 301 165 1.7 0 1.8 1.4 12/11/2006 16:50:00 7 0.9 9.5 4.6 7.1 0.9 9.5 4.9 5.9 1 9.5 3.4 296 7 290 165 1.7 0 1.8 1.6 12/11/2006 17:00:00 6.4 0.8 8.4 3.8 6.5 0.8 8.4 3.8 5.5 0.9 8.4 2.6 297 10 294 165 1.7 0 1.8 1.6 12/11/2006 17:10:00 6 0.9 8.4 3.8 6.1 1 8.4 3.4 5.3 0.9 8.8 2.3 302 9 286 165 1.8 0 1.8 1.6 12/11/2006 17:20:00 5.2 0.7 7.2 3.8 5.2 0.7 7.2 3.4 4.5 0.7 6.1 2.6 307 10 302 165 1.8 0 1.8 1.4 12/11/2006 17:30:00 5.1 0.6 6.8 3.4 5 0.7 6.8 3.4 4.3 0.7 6.8 2.6 306 9 300 165 1.8 0 1.8 1.6 12/11/2006 17:40:00 8 1.6 12.2 4.6 7.9 1.6 12.6 4.6 7.9 1.7 12.6 3.8 336 12 345 165 1.8 0.1 2.3 1.4 12/11/2006 17:50:00 9.3 1.2 13 6.5 9.2 1.2 13.3 6.8 9.3 1.1 12.2 6.8 334 10 338 165 1.8 0.1 2.3 1.4 12/11/2006 18:00:00 9.1 1.5 13 5.3 9 1.5 12.6 5.7 8.9 1.5 12.6 5.3 328 9 334 165 1.7 0.2 1.8 1.4 12/11/2006 18:10:00 9 1.1 13 6.5 8.9 1.1 13.7 6.1 8.9 1.1 11.8 6.1 327 11 302 165 1.7 0.2 1.8 1.4 12/11/2006 18:20:00 8.9 1.1 12.2 6.1 8.8 1.1 11.8 6.1 8.4 1.2 11.8 5.3 325 13 296 165 1.7 0.1 2.1 1.4 12/11/2006 18:30:00 9.1 1.3 13.7 5.7 9.1 1.3 13.3 5.7 8.7 1.3 13.3 4.9 326 13 334 165 1.8 0.1 2.3 1.4 12/11/2006 18:40:00 8.8 1.4 12.2 5.3 8.7 1.5 12.2 5.3 8.4 1.5 13 4.9 328 13 338 165 1.8 0.1 2.3 1.4 12/11/2006 18:50:00 7.4 1.7 11.5 4.2 7.3 1.7 11.5 4.2 6.7 1.5 10.7 2.6 336 15 334 165 1.7 0.2 1.8 1.4 12/11/2006 19:00:00 5.9 1.1 9.5 3 5.7 1.2 9.5 2.6 5.6 1.2 8.8 2.3 342 11 347 165 1.7 0.1 1.8 1.4 12/11/2006 19:10:00 6.2 1.7 9.9 3 5.9 2 10.7 2.6 5.9 1.7 10.3 2.6 343 14 339 165 1.7 0.1 1.8 1.4 12/11/2006 19:20:00 9.1 1.3 12.6 5.7 8.8 1.7 13 4.9 9.1 1.6 13 4.6 348 7 347 165 1.6 0.1 1.8 1.1 12/11/2006 19:30:00 8.9 1 11.5 6.1 8.7 1.3 11.5 4.2 9.1 1.1 11.8 6.5 345 7 346 165 1.5 0 1.8 1.1 12/11/2006 19:40:00 9.1 1.3 12.6 6.1 8.9 1.4 11.8 5.3 9.2 1.2 12.2 6.5 346 7 1 165 1.5 0 1.8 1.1 12/11/2006 19:50:00 9 1.4 12.2 4.6 8.6 1.7 12.2 4.2 9.2 1.3 13 5.7 346 8 327 165 1.5 0.1 1.8 0.9 12/11/2006 20:00:00 10 1.6 14.5 6.1 10 1.8 14.1 5.3 10.2 1.5 13.7 6.5 345 7 334 165 1.3 0.1 1.6 0.9 12/11/2006 20:10:00 9.8 1 12.6 7.2 10 1.2 12.6 6.5 9.9 1.2 13 6.8 344 6 349 165 1.1 0 1.6 0.4 12/11/2006 20:20:00 9.5 1.2 12.6 6.8 9.4 1.6 13 4.6 9.5 1.3 13 4.9 344 8 344 165 1 0 1.4 0.9 12/11/2006 20:30:00 8.4 1.2 11.1 4.6 8.3 1.3 11.5 4.6 8.5 1.3 11.8 4.9 342 9 342 165 1 0 1.4 0.2 12/11/2006 20:40:00 8.4 1.4 12.2 5.3 8.2 1.5 12.6 5.3 8.4 1.4 11.8 5.3 335 12 337 165 1 0 1.6 0.4 12/11/2006 20:50:00 7.6 1.2 10.7 5.3 7.5 1.2 10.7 5.3 7.2 1.5 11.5 4.2 319 11 331 165 1.2 0.2 1.6 0.4 12/11/2006 21:00:00 6.3 0.8 8.8 4.6 6.3 0.8 8.8 3.8 5.7 1.1 8.4 3 303 20 335 165 0.9 0.1 1.4 0.7 12/11/2006 21:10:00 7.2 1 9.9 4.6 7.2 1.1 9.9 4.2 6.3 1.3 9.1 3.4 292 11 287 165 0.7 0 1.1 0.4 12/11/2006 21:20:00 6.8 1 8.8 4.2 6.8 1 9.1 3.8 6.2 1.2 9.1 3.4 295 9 300 165 0.8 0.1 1.1 0.4 12/11/2006 21:30:00 6.4 1.2 9.1 3 6.4 1.2 9.1 2.6 6.1 1.2 9.5 3.4 290 10 295 165 0.7 0 0.9 0.2 12/11/2006 21:40:00 4.9 1 7.6 2.3 4.8 1 7.6 1.1 4.9 1 7.2 1.5 297 20 341 165 0.7 0 0.9 0.4 12/11/2006 21:50:00 7.3 1.1 9.9 4.6 7.1 1.1 9.5 3.8 6.8 1.1 9.5 4.6 332 9 327 165 0.8 0 1.1 0.7 12/11/2006 22:00:00 7.4 0.8 9.5 5.3 7.3 0.8 9.1 5.3 7.1 0.8 9.5 5.3 337 7 336 165 1 0 1.6 0.9 12/11/2006 22:10:00 5.1 1 7.6 2.6 5 1 8.4 2.6 4.7 0.9 7.6 2.6 305 16 334 165 0.7 0.2 1.4 0.2 12/11/2006 22:20:00 5.9 1.1 9.1 3.4 5.7 1.1 9.1 2.6 5.2 1.1 8.8 3 323 17 340 165 0.5 0.2 0.9 -0.1 12/11/2006 22:30:00 7.1 1 9.1 3.8 6.9 1 9.1 3.8 6.5 1.1 8.8 3.4 328 13 335 165 1 0 1.4 0.7 12/11/2006 22:40:00 7.1 1.3 10.7 4.6 7 1.3 9.9 4.6 6.5 1.3 9.5 3.4 329 13 337 165 0.9 0.1 1.4 0.7 12/11/2006 22:50:00 9 0.8 11.1 5.3 8.9 0.9 11.1 5.7 8.3 1 10.7 5.3 340 6 344 165 1.2 0 1.4 1.1 12/11/2006 23:00:00 6.1 1.5 9.1 3 5.9 1.5 9.5 3 5.6 1.5 9.9 2.6 323 17 348 165 1.1 0.2 1.6 0.7 12/11/2006 23:10:00 5.2 0.8 8 3.4 5.1 0.9 8 3 4.3 0.8 8 2.3 299 9 294 165 0.7 0.1 0.9 0.4 12/11/2006 23:20:00 6.7 1.1 10.3 3.8 6.6 1.2 10.3 3.4 5.7 1.1 8.8 3 306 10 312 165 0.5 0.1 0.9 0.2 12/11/2006 23:30:00 7.3 1.1 10.7 4.9 7.1 1.1 10.3 4.6 6.8 1.1 9.9 4.9 329 15 342 165 0.5 0.3 1.1 -0.1 12/11/2006 23:40:00 8.2 1 11.1 5.7 8.1 1.1 11.1 5.3 7.8 1 10.3 5.3 338 11 351 165 0.8 0 1.1 0.2 12/11/2006 23:50:00 7.8 1 11.5 5.3 7.6 0.9 9.9 4.6 7.6 0.9 10.3 5.7 338 10 358 165 0.8 0 1.1 0.2 12/12/2006 00:00:00 8.2 1.1 10.3 5.3 8.1 1.1 10.7 5.7 7.8 1.1 10.3 4.9 338 9 354 165 0.8 0.1 1.4 0.4 12/12/2006 00:10:00 8.2 1 10.3 5.7 8 1.1 10.3 4.6 8.1 1 10.7 5.3 344 8 338 165 0.8 0.1 1.4 0.4 12/12/2006 00:20:00 7.7 1.3 12.6 4.9 7.5 1.3 10.7 4.6 7.3 1.3 11.5 4.6 341 9 354 165 0.8 0 1.1 0.7 12/12/2006 00:30:00 8.5 1.4 12.2 5.3 8.3 1.6 12.2 4.6 8.3 1.3 11.8 3.8 345 10 343 165 0.9 0 1.1 0.7 12/12/2006 00:40:00 8.1 0.9 10.7 5.3 7.2 1.4 9.9 3.4 8.4 0.8 10.3 6.5 350 9 4 165 0.9 0 1.4 0.7 12/12/2006 00:50:00 8 1 10.7 5.7 7.8 1.1 11.1 4.6 8 0.9 10.7 5.7 341 10 348 165 0.8 0.1 1.4 0.4 12/12/2006 01:00:00 8.6 1.3 12.2 4.2 8.5 1.3 12.2 4.2 8.4 1.4 11.5 4.9 327 14 312 165 0.8 0.1 1.4 0.4 12/12/2006 01:10:00 10.1 1.2 13 6.8 10 1.2 13 6.5 9.4 1.3 13.3 6.5 317 10 317 165 0.7 0.2 1.4 0.2 12/12/2006 01:20:00 12.1 0.7 13.7 9.9 12 0.6 13.7 9.9 11.4 0.9 13.3 8.4 314 3 310 165 0.4 0.1 0.7 -0.3 12/12/2006 01:30:00 12.9 0.4 14.1 11.5 12.7 0.5 14.1 11.5 11.9 0.6 13.3 9.9 313 2 312 165 0.2 0 0.7 0.2 12/12/2006 01:40:00 11.9 1 14.9 8.8 11.8 1 14.9 8.8 11.2 0.9 13.7 8.4 314 4 309 165 0.3 0.2 0.7 -0.1 12/12/2006 01:50:00 10.5 0.8 13.3 7.2 10.4 0.8 13 7.2 9.4 0.8 11.8 7.2 313 4 309 165 0.2 0.1 0.7 -0.1 12/12/2006 02:00:00 9.9 0.8 13.7 8 9.7 0.8 13.7 7.6 9 0.8 13 6.1 315 6 315 165 0.3 0 0.7 -0.1 12/12/2006 02:10:00 9.3 0.7 11.1 6.5 9.1 0.7 10.7 6.5 8.7 0.8 10.7 5.7 315 5 315 165 0.3 0.1 0.7 -0.1 12/12/2006 02:20:00 7.5 1 9.9 5.3 7.4 1 9.9 4.9 7.3 1 9.9 5.3 327 11 316 165 0.4 0 0.7 0.2 12/12/2006 02:30:00 6.6 0.9 8.8 4.9 6.5 0.8 8.8 4.6 5.7 0.7 8.8 3.8 310 9 302 165 0.2 0.1 0.7 -0.1 12/12/2006 02:40:00 6.7 1.3 9.9 3 6.6 1.3 9.5 2.6 5.5 0.9 9.9 3.4 308 12 289 165 0.1 0.1 0.4 -0.3 12/12/2006 02:50:00 3.9 1.2 7.2 1.1 3.8 1.3 6.8 0.4 3.1 1.1 5.7 0.4 312 15 300 165 0.1 0.1 0.4 -0.3 12/12/2006 03:00:00 4.5 1.6 7.6 1.1 4.5 1.6 8 1.1 3.6 1.7 8.4 0.4 289 13 279 165 0.1 0.2 0.7 -0.5 12/12/2006 03:10:00 7.4 1.1 9.5 4.6 7.3 1.1 9.5 4.2 6.1 1 9.5 3 296 8 288 165 0.3 0.1 0.7 -0.3 12/12/2006 03:20:00 9 0.9 11.1 6.5 9 0.9 11.1 6.8 6.9 1 9.9 4.9 298 5 299 165 0.2 0.1 0.7 -0.3 12/12/2006 03:30:00 9.2 1.2 12.6 6.5 9.2 1.2 12.6 6.5 7.3 1.3 11.1 4.9 302 8 297 165 0.1 0.1 0.2 -0.3 12/12/2006 03:40:00 9.7 1.3 13.3 6.1 9.7 1.3 13.3 6.1 8.2 1.5 12.2 4.6 309 7 306 165 0 0.1 0.2 -0.5 12/12/2006 03:50:00 10.4 1 13 8.4 10.4 1 13 8.4 8.7 1.2 13 6.1 310 6 308 165 0 0 0.2 -0.3 12/12/2006 04:00:00 10.9 0.7 12.6 9.1 10.9 0.6 12.6 9.1 9.1 1.2 11.5 6.1 309 5 304 165 0.1 0 0.7 -0.1 12/12/2006 04:10:00 12 1 14.5 9.9 12 1 14.1 9.9 8.5 1 12.2 6.5 303 4 299 165 0.2 0 0.4 -0.3 12/12/2006 04:20:00 12.3 0.6 13.7 10.3 12.3 0.6 13.7 10.3 8.4 0.7 11.1 6.5 302 3 303 165 0.1 0 0.2 -0.1 12/12/2006 04:30:00 11.6 0.6 13.7 10.3 11.6 0.6 13.7 9.9 8.3 0.9 12.2 6.5 303 4 304 165 0 0 0.4 -0.3 12/12/2006 04:40:00 11.2 0.9 12.6 8 11.1 0.9 12.6 7.6 9.2 1 11.8 6.5 310 5 305 165 -0.1 0 0.2 -0.5 12/12/2006 04:50:00 10.3 1 12.2 6.8 10.2 0.9 11.8 6.8 8.5 1.1 11.8 6.1 309 5 313 165 -0.2 0 0.2 -0.8 12/12/2006 05:00:00 9.5 1.1 12.2 6.8 9.4 1.1 12.2 6.8 7.9 1.1 10.7 4.9 309 6 302 165 -0.2 0.1 -0.1 -0.8 12/12/2006 05:10:00 10 0.8 11.8 7.6 10 0.8 11.8 7.6 7.7 1 10.3 5.3 307 4 306 165 -0.1 0 0.2 -0.8 12/12/2006 05:20:00 10.4 1.2 13 7.2 10.3 1.2 12.6 6.8 9 1.2 12.6 5.7 311 5 309 165 -0.2 0.2 0.2 -0.8 12/12/2006 05:30:00 9.3 0.5 10.7 7.6 9.2 0.5 10.7 7.6 8.5 0.6 9.9 6.5 313 3 312 165 -0.3 0 -0.3 -1 12/12/2006 05:40:00 8.6 0.8 10.3 6.5 8.5 0.8 10.3 6.5 7.6 1 9.5 4.9 310 5 310 165 -0.3 0 -0.3 -0.8 12/12/2006 05:50:00 9.2 0.6 10.7 7.2 9.2 0.6 10.7 7.2 8 0.7 9.9 5.7 310 3 309 165 -0.4 0 -0.3 -0.8 12/12/2006 06:00:00 9 0.6 10.7 7.2 8.9 0.6 10.7 7.2 8.3 0.7 11.1 6.5 315 5 320 165 -0.4 0 -0.3 -0.8 12/12/2006 06:10:00 8.6 0.7 10.7 6.8 8.5 0.7 10.3 6.8 7.8 0.6 9.1 5.7 313 4 310 165 -0.3 0 -0.1 -0.5 12/12/2006 06:20:00 9.5 0.7 11.8 8 9.4 0.7 11.1 7.6 8.6 0.8 10.7 6.8 313 4 305 165 -0.3 0.1 -0.1 -0.8 12/12/2006 06:30:00 8.9 1 11.8 6.5 8.9 1 11.5 6.5 7.7 1.3 11.5 4.9 309 7 313 165 -0.2 0.1 0.2 -0.8 12/12/2006 06:40:00 9.1 1.3 12.2 5.7 9.1 1.3 12.2 6.1 7.1 1.3 10.7 4.6 303 8 306 165 0.1 0.2 0.4 -0.5 12/12/2006 06:50:00 9.9 1 12.2 7.2 9.9 1 12.2 7.6 7 1 11.1 4.6 302 4 302 165 0 0.1 0.2 -0.3 12/12/2006 07:00:00 8.8 0.7 10.3 6.8 8.8 0.7 10.7 6.8 6.3 0.7 8.8 4.9 302 4 303 165 -0.2 0.1 0.2 -0.8 12/12/2006 07:10:00 8.9 0.8 11.1 6.5 8.8 0.8 10.7 6.8 6.4 0.7 9.1 4.6 302 5 305 165 -0.3 0.1 -0.1 -0.8 12/12/2006 07:20:00 9.2 0.9 11.5 6.5 9.2 1 11.1 6.5 6.8 0.8 9.5 4.6 302 5 292 165 -0.3 0 -0.3 -0.8 12/12/2006 07:30:00 7.9 0.9 9.9 5.7 7.8 0.9 9.9 5.7 6.7 1 9.1 3.8 308 6 309 165 -0.5 0 -0.3 -0.8 12/12/2006 07:40:00 8 0.7 9.9 6.1 8 0.7 9.9 6.1 6.3 0.8 8.4 4.6 305 5 302 165 -0.4 0 -0.3 -0.8 12/12/2006 07:50:00 7.7 0.7 9.1 6.1 7.6 0.7 9.1 5.7 6 0.8 8.4 4.2 304 6 307 165 -0.5 0 -0.1 -0.8 12/12/2006 08:00:00 7.7 0.6 8.8 5.7 7.7 0.6 8.8 5.7 5.4 0.6 6.8 3.4 300 3 298 165 -0.4 0 -0.3 -0.5 12/12/2006 08:10:00 6.3 0.8 9.9 4.9 6.3 0.8 9.9 4.9 4.9 1.1 9.9 2.6 297 6 282 165 -0.3 0 -0.1 -0.5 12/12/2006 08:20:00 6.5 0.9 9.1 4.6 6.5 0.9 8.8 4.6 4.8 1 9.1 2.6 298 5 287 165 -0.3 0 -0.1 -0.5 12/12/2006 08:30:00 7.4 0.5 8.8 5.3 7.4 0.5 8.8 5.3 5.6 0.7 7.2 3.8 295 3 300 165 -0.3 0 -0.1 -0.5 12/12/2006 08:40:00 6.8 0.5 8 5.3 6.8 0.5 8 5.7 5.1 0.7 7.2 3.4 296 3 297 165 -0.3 0 -0.1 -0.5 12/12/2006 08:50:00 6.6 0.6 8 4.9 6.6 0.6 8 4.9 4.8 0.7 6.5 2.6 295 4 296 165 -0.3 0 -0.1 -0.5 12/12/2006 09:00:00 6.2 0.6 7.6 4.6 6.2 0.6 7.6 4.2 4.4 0.5 5.7 3 301 4 300 165 -0.3 0 0.2 -0.5 12/12/2006 09:10:00 6.8 0.6 8.4 4.9 6.7 0.6 8.4 5.3 4.8 0.5 6.5 3.4 301 4 298 165 -0.2 0.1 -0.1 -0.8 12/12/2006 09:20:00 7.4 0.7 9.1 4.2 7.3 0.7 8.8 4.2 5.4 0.8 7.6 2.6 302 4 306 165 -0.1 0 0.2 -0.8 12/12/2006 09:30:00 6.7 0.6 8 4.6 6.7 0.6 8.4 4.2 5.3 0.8 7.6 3.4 306 5 322 165 -0.1 0 0.2 -0.8 12/12/2006 09:40:00 6.9 0.4 7.6 5.3 6.8 0.4 7.6 5.3 4.8 0.5 6.1 3.8 302 3 301 165 -0.2 0 -0.1 -0.3 12/12/2006 09:50:00 6.7 0.5 8 4.9 6.6 0.5 8 4.9 4.8 0.5 6.1 3.4 302 3 302 165 -0.1 0 0.2 -0.3 12/12/2006 10:00:00 7.3 0.6 8.8 5.7 7.2 0.6 8.8 5.7 5.2 0.5 6.8 4.2 304 3 302 165 -0.1 0 0.2 -0.1 12/12/2006 10:10:00 6.3 0.5 7.6 4.6 6.2 0.5 7.6 4.9 5 0.7 6.8 3.4 305 6 301 165 -0.1 0 0.2 -0.3 12/12/2006 10:20:00 5.5 0.5 6.8 4.2 5.4 0.5 6.8 4.2 4.8 0.7 6.5 3 308 6 306 165 0.1 0.1 0.2 -0.3 12/12/2006 10:30:00 5.1 0.6 6.5 3.8 5.1 0.6 6.5 3.8 4.1 0.6 5.7 2.3 306 8 309 165 0.2 0.1 0.7 -0.1 12/12/2006 10:40:00 4.3 0.7 6.1 1.9 4.3 0.7 5.7 1.9 3.6 0.7 5.7 2.3 300 10 291 165 0.2 0.2 0.7 -0.3 12/12/2006 10:50:00 3.6 0.6 5.3 1.9 3.6 0.6 5.3 2.3 2.9 0.7 4.6 1.1 298 9 293 165 0.5 0 0.9 0.2 12/12/2006 11:00:00 2.7 0.6 4.2 1.5 2.7 0.6 4.6 1.1 2.3 0.6 4.6 0.7 308 14 298 165 0.4 0 0.9 0.2 12/12/2006 11:10:00 3.2 0.9 4.9 1.1 3.3 0.9 5.3 1.1 3 0.9 5.7 0.7 296 15 281 165 0.4 0.1 0.9 -0.1 12/12/2006 11:20:00 3.2 0.6 4.9 1.1 3.2 0.6 4.9 1.5 2.8 0.5 4.6 1.5 310 11 360 165 0.2 0.1 0.9 -0.1 12/12/2006 11:30:00 3.5 0.6 4.9 1.9 3.3 0.7 5.3 1.5 3.1 0.6 4.9 1.5 323 22 334 165 0.2 0.2 0.7 -0.3 12/12/2006 11:40:00 2.8 0.4 4.2 1.9 2.5 0.5 4.2 1.1 2.7 0.4 3.8 1.5 345 9 351 165 0.2 0.1 0.7 -0.5 12/12/2006 11:50:00 2.7 0.4 4.2 1.9 2.4 0.5 3.8 0.4 2.7 0.4 3.8 1.9 342 12 6 165 0.4 0.1 0.7 -0.5 12/12/2006 12:00:00 2.8 0.4 4.2 1.9 2.6 0.6 4.6 0.7 2.8 0.4 3.4 1.5 336 13 350 165 0.4 0.1 0.9 -0.1 12/12/2006 12:10:00 3 0.7 4.6 1.5 2.5 1 4.6 0.4 2.9 0.7 4.6 1.5 357 16 336 165 0.7 0.1 0.9 0.2 12/12/2006 12:20:00 3.6 0.7 4.9 1.5 3.4 0.9 4.9 1.1 3.6 0.7 4.9 1.9 345 7 335 165 0.8 0.2 1.1 0.2 12/12/2006 12:30:00 4 0.6 5.3 2.3 3.7 1 5.7 1.1 4 0.6 5.3 2.6 346 8 351 165 0.8 0.2 1.4 0.2 12/12/2006 12:40:00 3.5 0.8 4.9 1.1 3.1 1 4.9 0.7 3.6 0.8 5.3 1.1 350 12 338 165 0.8 0.2 1.1 0.2 12/12/2006 12:50:00 1.6 0.9 3.8 0.4 1 0.8 3.4 0.4 1.4 1 4.2 0.4 358 8 4 165 1 0.1 1.4 0.7 12/12/2006 13:00:00 1.1 0.5 2.3 0.4 0.9 0.5 2.3 0.4 1.1 0.6 2.6 0.4 39 14 45 165 1 0.1 1.4 0.7 12/12/2006 13:10:00 1.8 0.4 2.6 0.7 1 0.5 2.3 0.4 1.9 0.5 3 0.4 11 6 15 165 0.9 0.1 1.4 0.7 12/12/2006 13:20:00 1.4 0.6 2.6 0.4 0.7 0.4 1.9 0.4 1.4 0.6 2.6 0.4 10 6 8 165 1.1 0.2 1.6 0.7 12/12/2006 13:30:00 2.4 0.3 3.4 1.9 1.1 0.5 2.3 0.4 2.3 0.3 3.4 1.5 358 5 4 165 0.9 0.1 1.4 0.7 12/12/2006 13:40:00 2.4 0.3 3 1.5 1 0.5 2.3 0.4 2.2 0.3 2.6 1.1 3 5 3 165 0.8 0.1 1.4 0.4 12/12/2006 13:50:00 2.4 0.3 3 1.5 1.2 0.4 2.6 0.4 2.4 0.3 3 1.5 7 3 5 165 0.8 0 1.4 0.7 12/12/2006 14:00:00 1.1 0.6 2.3 0.4 0.7 0.4 1.9 0.4 0.9 0.6 2.3 0.4 16 8 7 165 0.9 0 1.4 0.7 12/12/2006 14:10:00 1.1 0.7 2.6 0.4 0.9 0.6 2.3 0.4 1 0.6 2.3 0.4 28 6 22 165 0.9 0.1 1.1 0.4 12/12/2006 14:20:00 1.2 0.6 2.6 0.4 1 0.6 2.6 0.4 1.2 0.5 2.3 0.4 25 10 28 165 0.9 0.1 1.4 0.4 12/12/2006 14:30:00 2.5 0.8 4.2 0.7 2.2 0.6 3.4 0.7 2.6 0.8 4.2 0.7 25 9 15 165 0.9 0.1 1.1 0.7 12/12/2006 14:40:00 3.5 0.5 4.9 2.3 2.5 0.7 4.2 0.7 3.6 0.5 4.6 2.3 12 3 12 165 0.9 0 1.4 0.4 12/12/2006 14:50:00 3.3 0.4 4.2 2.3 1.7 0.5 3.8 0.4 3.2 0.4 4.2 1.9 4 6 1 165 0.8 0 1.4 0.7 12/12/2006 15:00:00 3.1 0.5 4.2 1.9 1.7 0.5 3.4 0.7 3 0.4 4.2 1.9 4 6 359 165 0.7 0 1.4 0.7 12/12/2006 15:10:00 3.7 0.4 4.9 3 2.2 0.7 4.6 0.7 3.7 0.4 4.9 3 8 5 6 165 0.7 0.1 0.9 0.2 12/12/2006 15:20:00 3.9 0.5 5.3 2.6 3.6 0.6 4.9 1.9 3.9 0.5 4.9 2.3 23 8 23 165 0.6 0.2 0.9 0.2 12/12/2006 15:30:00 4 0.2 4.6 3.4 3.8 0.3 4.6 2.3 4.1 0.3 4.9 3 25 5 34 165 0.5 0.1 0.9 -0.1 12/12/2006 15:40:00 3.9 0.3 4.9 3 3 0.7 4.6 1.1 4.2 0.3 4.9 3 14 6 360 165 0.4 0 0.7 -0.1 12/12/2006 15:50:00 3.5 0.5 4.6 2.3 3.2 0.6 4.2 1.5 3.8 0.5 4.9 2.3 26 5 26 165 0.4 0 0.7 -0.1 12/12/2006 16:00:00 4 0.6 5.3 2.3 3.8 0.7 4.9 1.9 4.3 0.5 5.3 2.6 27 4 31 165 0.4 0.1 0.7 -0.1 12/12/2006 16:10:00 4.2 0.3 4.9 3 4.1 0.3 4.6 2.6 4.2 0.4 4.9 2.6 26 3 25 165 0.2 0.2 0.7 -0.5 12/12/2006 16:20:00 4 0.4 4.9 3 3.8 0.5 4.6 2.6 3.8 0.5 4.9 2.3 24 4 24 165 0.2 0 0.2 -0.1 12/12/2006 16:30:00 4.1 0.6 4.9 2.6 3.8 0.5 4.9 2.3 3.9 0.6 4.9 2.3 22 4 20 165 0.1 0 0.2 -0.3 12/12/2006 16:40:00 3.5 0.5 4.9 2.6 3 0.6 4.6 1.5 3.5 0.5 4.9 2.3 17 4 18 165 0 0 0.2 -0.3 12/12/2006 16:50:00 3.4 0.3 4.2 2.6 2.7 0.5 3.8 1.1 3.4 0.3 4.2 2.6 15 3 19 165 -0.1 0 0.2 -0.5 12/12/2006 17:00:00 3.4 0.3 4.2 2.6 3.1 0.3 3.8 1.9 3.3 0.3 4.2 2.3 24 4 25 165 -0.2 0 0.2 -0.5 12/12/2006 17:10:00 4.1 0.4 4.9 3 3.9 0.4 4.9 2.6 4 0.5 4.9 2.6 25 4 31 165 -0.3 0 -0.1 -0.8 12/12/2006 17:20:00 3.4 0.3 4.6 2.6 3.2 0.4 4.2 2.3 3.4 0.4 4.6 2.3 24 5 23 165 -0.3 0 -0.1 -0.8 12/12/2006 17:30:00 3.1 0.2 3.8 2.3 2.7 0.3 3.4 1.5 3.1 0.3 3.8 2.3 18 3 19 165 -0.4 0 -0.3 -0.5 12/12/2006 17:40:00 2.8 0.3 3.4 2.3 2.7 0.4 3.4 1.9 2.8 0.4 3.8 1.5 27 5 25 165 -0.3 0 -0.3 -0.5 12/12/2006 17:50:00 2.6 0.3 3.4 1.9 2.6 0.3 3.4 1.9 2.7 0.3 3.4 1.9 35 8 48 165 -0.2 0 -0.1 -0.5 12/12/2006 18:00:00 2.5 0.5 3.8 1.1 2.4 0.6 3.8 0.7 2.5 0.5 4.2 1.1 50 7 54 165 -0.1 0 -0.1 -0.3 12/12/2006 18:10:00 2.1 0.4 3.4 1.1 1.9 0.4 3 1.1 2.2 0.4 3 1.1 36 7 33 165 -0.1 0 0.2 -0.8 12/12/2006 18:20:00 1.6 0.3 2.6 0.7 1.4 0.3 2.3 0.7 1.6 0.3 2.6 0.7 39 6 44 165 -0.1 0 0.2 -0.5 12/12/2006 18:30:00 2.4 0.4 3.4 1.1 2.2 0.4 3 0.7 2.3 0.4 3.4 1.1 24 6 26 165 -0.1 0 0.2 -0.8 12/12/2006 18:40:00 3.3 0.5 4.2 2.3 3.1 0.5 4.2 1.5 3.3 0.5 4.2 1.9 20 3 22 165 -0.1 0 0.2 -0.8 12/12/2006 18:50:00 4.4 0.6 6.1 3 3.7 0.8 5.7 1.5 4.4 0.6 6.1 2.6 17 6 18 165 -0.1 0 0.2 -0.1 12/12/2006 19:00:00 3.4 0.7 5.3 1.9 3.2 0.7 4.9 1.5 3.4 0.7 4.9 1.9 32 7 28 165 -0.1 0 0.2 -0.3 12/12/2006 19:10:00 2.6 0.4 3.4 1.9 2.3 0.4 3.4 1.5 2.5 0.5 3.4 1.1 37 8 39 165 -0.1 0 0.2 -0.3 12/12/2006 19:20:00 2.8 0.6 4.2 1.5 2.6 0.6 4.2 1.1 2.8 0.5 4.2 1.5 39 11 15 165 -0.1 0 0.2 -0.1 12/12/2006 19:30:00 2.6 0.3 3 1.5 2.5 0.3 3 1.5 2.7 0.3 3.4 1.5 38 5 50 165 -0.1 0 0.2 -0.1 12/12/2006 19:40:00 1.8 0.5 2.6 0.7 1.6 0.6 2.6 0.4 1.6 0.6 3 0.4 37 0 37 165 -0.1 0 0.2 -0.5 12/12/2006 19:50:00 2.3 0.7 4.6 0.7 2.3 0.8 4.6 0.4 2.1 0.8 4.6 0.7 48 12 70 165 -0.1 0 0.2 -0.3 12/12/2006 20:00:00 3 0.5 4.2 1.9 3 0.5 4.2 1.5 2.9 0.5 3.8 1.5 51 9 44 165 -0.1 0 0.2 -0.3 12/12/2006 20:10:00 2.9 0.6 4.2 1.5 2.9 0.7 4.2 1.5 2.7 0.5 4.2 1.5 56 8 64 165 -0.1 0 0.2 -0.3 12/12/2006 20:20:00 2.2 0.7 3.8 1.1 1.9 0.8 3.8 0.4 1.9 0.7 3.8 0.4 41 11 33 165 -0.1 0 0.2 -0.3 12/12/2006 20:30:00 3.3 0.5 4.6 2.3 2.8 0.8 4.2 0.7 2.9 0.5 4.2 1.9 29 14 46 165 -0.1 0 0.2 -0.3 12/12/2006 20:40:00 3.7 0.4 4.6 2.3 3 0.8 4.2 1.1 3.4 0.4 4.2 1.9 18 8 10 165 -0.1 0 0.2 -0.3 12/12/2006 20:50:00 3.3 0.5 4.6 1.9 3.1 0.5 4.2 1.9 2.9 0.5 3.8 1.5 40 5 44 165 -0.1 0 0.2 -0.3 12/12/2006 21:00:00 3.8 0.5 5.3 2.6 3.6 0.4 4.9 2.3 3.6 0.5 4.9 2.6 26 7 20 165 -0.1 0 0.2 -0.3 12/12/2006 21:10:00 4.2 0.3 4.9 3 4 0.3 4.9 3 4 0.4 4.9 3 26 5 25 165 -0.1 0 0.2 -0.3 12/12/2006 21:20:00 3.7 0.4 4.6 2.6 3.3 0.6 4.6 0.7 3.7 0.5 4.6 2.3 23 6 22 165 -0.1 0 0.2 -0.3 12/12/2006 21:30:00 3.9 0.4 4.6 3 3.5 0.5 4.6 1.1 3.7 0.4 4.6 2.3 22 4 18 165 -0.1 0 0.2 -0.3 12/12/2006 21:40:00 3.2 0.6 4.2 1.9 2.9 0.6 4.2 1.5 3.2 0.6 4.2 1.9 30 5 22 165 -0.1 0 0.2 -0.3 12/12/2006 21:50:00 2.9 0.5 3.8 1.9 1.7 0.6 3.4 0.7 2.7 0.4 3.4 1.9 7 11 22 165 -0.1 0 0.2 -0.5 12/12/2006 22:00:00 2.8 0.2 3.4 2.3 1.4 0.4 2.6 0.7 2.6 0.2 3.4 1.9 354 3 356 165 -0.2 0 0.7 -0.3 12/12/2006 22:10:00 2.6 0.4 4.2 1.9 1.8 0.8 4.2 0.4 2.3 0.4 3.8 1.5 16 10 22 165 -0.3 0 -0.1 -0.3 12/12/2006 22:20:00 2.2 0.4 3.4 1.1 1.2 0.6 3 0.4 1.9 0.5 2.6 0.7 358 11 7 165 -0.3 0 -0.1 -0.5 12/12/2006 22:30:00 2.6 0.5 4.2 1.5 1.5 0.6 3 0.4 2.5 0.5 4.2 1.1 9 9 4 165 -0.3 0 -0.1 -0.3 12/12/2006 22:40:00 3.2 0.5 4.2 2.3 2.3 0.9 4.2 0.4 3 0.5 3.8 1.9 15 9 23 165 -0.2 0 -0.1 -0.3 12/12/2006 22:50:00 3.6 0.6 4.9 1.9 2.8 1 4.6 0.7 3.5 0.6 4.6 1.9 15 7 15 165 -0.1 0 0.2 -0.3 12/12/2006 23:00:00 3.1 0.8 4.9 1.9 2.4 1.1 4.6 0.4 3.1 0.8 4.9 1.5 15 8 28 165 -0.1 0 0.2 -0.3 12/12/2006 23:10:00 2.9 0.6 4.2 1.5 2.3 1 4.2 0.4 2.8 0.5 3.8 1.5 342 13 345 165 -0.2 0.1 0.2 -0.5 12/12/2006 23:20:00 3.8 0.4 4.9 2.6 3.7 0.4 4.9 2.6 3.7 0.4 4.6 3 329 5 338 165 -0.5 0 -0.3 -0.5 12/12/2006 23:30:00 4 0.4 5.3 3 3.8 0.5 5.3 2.6 3.9 0.5 4.9 2.6 335 6 343 165 -0.5 0 -0.3 -0.5 12/12/2006 23:40:00 3.8 0.5 5.3 2.6 3 0.6 4.6 1.1 3.6 0.4 4.6 2.6 350 7 2 165 -0.4 0 -0.3 -0.5 12/12/2006 23:50:00 4.9 0.4 5.7 3.8 2.9 0.5 4.6 1.5 4.8 0.3 5.7 3.8 3 6 355 165 -0.3 0 -0.3 -0.5 12/13/2006 00:00:00 5.2 0.4 6.1 4.2 3.3 0.6 4.9 1.9 5.1 0.4 6.1 3.4 10 4 7 165 -0.5 0 -0.3 -0.5 12/13/2006 00:10:00 5.3 0.4 6.5 4.6 2.9 0.7 4.9 1.5 5.2 0.3 6.1 4.6 2 5 1 165 -0.6 0 -0.3 -1 12/13/2006 00:20:00 4.9 0.3 6.1 4.2 3.3 0.9 5.7 1.5 4.9 0.3 5.7 3.8 355 5 2 165 -0.6 0 -0.5 -1.2 12/13/2006 00:30:00 5.6 0.6 7.2 4.2 3.3 0.9 6.1 1.9 5.6 0.6 8 4.6 2 7 18 165 -0.7 0 -0.5 -1.2 12/13/2006 00:40:00 5.6 0.6 7.2 4.6 3.5 1.1 7.2 1.9 5.5 0.6 7.2 4.2 2 9 358 165 -0.8 0.1 -0.5 -1.4 12/13/2006 00:50:00 5.6 0.4 6.8 4.2 3.7 1 5.7 1.9 5.5 0.5 6.8 4.2 358 7 359 165 -0.9 0.1 -0.5 -1.4 12/13/2006 01:00:00 6.7 0.8 8.4 4.6 4.2 1 7.2 1.9 6.4 0.9 8.8 4.2 3 7 351 165 -0.9 0.1 -0.8 -1.4 12/13/2006 01:10:00 6.8 0.6 8.4 5.3 4.3 1 7.6 2.6 6.8 0.7 8.4 4.9 2 7 2 165 -1 0 -0.8 -1.2 12/13/2006 01:20:00 6.5 0.9 9.1 4.9 4.3 1.1 7.6 2.3 6.4 0.8 8.8 4.6 0 7 7 165 -1 0 -0.8 -1.2 12/13/2006 01:30:00 5.5 0.5 7.2 4.2 3.6 0.8 5.3 1.9 5.4 0.6 6.8 3.8 359 7 7 165 -1.2 0 -0.8 -1.2 12/13/2006 01:40:00 6 0.5 7.6 4.9 3.7 0.8 6.1 2.3 6 0.5 7.2 4.9 1 6 1 165 -1.2 0 -1 -1.2 12/13/2006 01:50:00 6.3 0.7 8.4 4.9 3.9 1 6.8 2.3 6.4 0.6 8.4 4.9 359 5 356 165 -1.2 0 -1 -1.4 12/13/2006 02:00:00 5.9 0.6 7.6 4.2 4.3 1 7.2 2.6 6.2 0.6 7.6 4.6 356 7 9 165 -1.3 0 -1.2 -1.4 12/13/2006 02:10:00 6.1 0.5 7.6 4.9 5.7 0.8 7.6 3 6.3 0.5 7.6 5.3 349 5 355 165 -1.3 0 -1.2 -1.4 12/13/2006 02:20:00 7 0.5 8.4 5.7 6.3 1 8.4 3.4 7 0.5 8.4 5.7 350 6 341 165 -1.4 0 -1.2 -1.4 12/13/2006 02:30:00 6.6 0.5 8 5.3 5.8 1.3 8.4 2.6 6.7 0.5 8.4 4.9 351 6 348 165 -1.4 0 -1.2 -1.4 12/13/2006 02:40:00 6.2 0.7 8.4 4.9 4.6 1.3 8.4 2.3 6.3 0.6 8 4.6 356 6 345 165 -1.5 0 -1.4 -1.7 12/13/2006 02:50:00 6 0.6 7.6 4.9 4.2 1 7.2 2.3 6.1 0.6 7.2 4.6 1 8 348 165 -1.5 0 -1.4 -1.7 12/13/2006 03:00:00 6.2 0.6 7.6 4.6 3.9 1 7.6 2.3 6.4 0.5 7.6 4.2 3 8 351 165 -1.5 0 -1.4 -1.7 12/13/2006 03:10:00 5.5 0.7 7.6 3.4 3.5 0.8 6.8 1.9 5.8 0.6 7.2 4.2 360 7 358 165 -1.6 0 -1.4 -1.9 12/13/2006 03:20:00 5 0.6 6.8 3.4 3.7 0.9 6.1 1.9 5.2 0.6 6.8 3.4 3 11 10 165 -1.6 0 -1.4 -1.7 12/13/2006 03:30:00 5.7 0.6 7.6 4.2 4.7 1 7.2 2.3 5.8 0.6 7.6 4.2 14 10 9 165 -1.7 0 -1.4 -1.9 12/13/2006 03:40:00 5.2 0.4 7.2 4.2 3.5 0.9 6.8 1.9 5.3 0.5 6.8 4.2 5 9 344 165 -1.7 0 -1.4 -1.9 12/13/2006 03:50:00 6.1 0.7 8 4.6 5.4 1 8.4 2.6 6.1 0.7 8 4.6 349 7 341 165 -1.9 0 -1.7 -1.9 12/13/2006 04:00:00 6.1 0.8 8 3.8 4.6 1.1 7.6 2.3 6.2 0.7 8 4.2 356 9 339 165 -1.9 0 -1.7 -2.1 12/13/2006 04:10:00 6 0.8 8.4 4.2 4.8 1.2 8 2.6 6 0.7 7.6 4.2 357 10 349 165 -1.9 0 -1.7 -2.1 12/13/2006 04:20:00 5.3 0.5 7.2 3.4 3.4 1 7.2 1.9 5.3 0.6 7.6 3.8 2 8 345 165 -1.9 0 -1.7 -1.9 12/13/2006 04:30:00 5.1 0.6 7.2 3.8 3.6 0.9 6.1 1.5 5.1 0.6 6.8 3.8 357 6 3 165 -1.8 0 -1.7 -1.9 12/13/2006 04:40:00 5.8 0.9 8.4 4.2 5 1.2 8.4 2.3 5.4 0.9 8.8 3.8 349 9 346 165 -1.8 0 -1.7 -1.9 12/13/2006 04:50:00 6 1 8.4 3.8 4.3 1.5 8 1.9 5.6 1 8 2.6 359 8 358 165 -1.8 0 -1.4 -1.9 12/13/2006 05:00:00 5 0.7 6.8 3.4 3.5 1.3 6.8 1.1 4.4 0.7 6.5 2.6 358 11 349 165 -1.9 0 -1.7 -1.9 12/13/2006 05:10:00 4.5 0.9 6.5 2.6 3.8 1.2 6.5 0.7 3.8 0.9 6.1 1.5 356 17 339 165 -2 0 -1.7 -2.1 12/13/2006 05:20:00 5 1.2 8.8 3.4 3.7 1.7 9.1 1.5 4.7 1.2 8.4 3 358 9 339 165 -2 0 -1.9 -2.1 12/13/2006 05:30:00 5 1.2 8.4 2.6 4.2 1.6 8 1.1 4.5 1.3 8 1.9 349 12 343 165 -2 0 -1.9 -2.1 12/13/2006 05:40:00 4 0.7 5.3 1.9 2.9 0.8 4.6 1.1 3.4 0.9 4.9 0.4 357 12 18 165 -2 0 -1.9 -2.1 12/13/2006 05:50:00 5.1 0.6 6.8 3.4 4.4 1.2 6.5 1.5 4.6 0.7 6.8 2.6 345 11 338 165 -2.1 0 -1.9 -2.1 12/13/2006 06:00:00 4.8 0.6 7.6 3 4.4 0.8 7.2 1.5 4.5 0.7 6.5 2.6 339 10 336 165 -2.1 0 -1.9 -2.4 12/13/2006 06:10:00 4 0.5 5.7 2.6 3.6 0.9 5.7 1.1 3.9 0.5 5.7 2.3 341 12 345 165 -2.1 0 -1.9 -2.1 12/13/2006 06:20:00 3.5 0.5 4.6 2.3 3.2 0.6 4.6 1.9 3.2 0.6 4.6 1.9 339 11 344 165 -2.1 0 -1.9 -2.1 12/13/2006 06:30:00 4.9 1.7 8.8 2.3 4.7 1.7 8.4 1.1 4.1 1.3 8 1.9 319 20 298 165 -2 0 -1.9 -2.1 12/13/2006 06:40:00 8 1.2 11.1 4.6 7.9 1.1 10.7 4.6 6.8 1.1 9.1 3.8 308 7 295 165 -2 0 -1.9 -2.1 12/13/2006 06:50:00 9 1.1 12.2 6.1 8.8 1 11.5 6.1 7.9 1.1 10.7 4.6 309 6 309 165 -2.1 0 -1.9 -2.1 12/13/2006 07:00:00 10.9 1.2 14.1 8 10.7 1.1 13.7 7.6 10 1.2 13.7 6.5 311 7 301 165 -2.1 0 -1.9 -2.4 12/13/2006 07:10:00 12 1.4 14.5 8.4 11.7 1.4 14.5 8.4 10.4 1.3 13.7 6.8 308 5 304 165 -2.2 0 -2.1 -2.6 12/13/2006 07:20:00 13.5 1.1 16.4 10.3 13.2 1 16.1 10.3 11.2 1.2 13.7 7.6 306 5 301 165 -2.5 0.1 -2.1 -2.6 12/13/2006 07:30:00 14.3 1.1 16.8 11.1 14 1.1 16.4 10.7 12.7 1.2 14.9 8.8 309 4 307 165 -2.5 0 -2.6 -2.8 12/13/2006 07:40:00 12.8 1.4 16.4 8.4 12.4 1.3 15.6 8 10.9 1.4 14.1 6.5 307 5 302 165 -2.6 0 -2.6 -2.8 12/13/2006 07:50:00 14.2 1.1 16.8 10.3 13.8 1.1 16.4 10.3 10.8 1 13.3 7.6 303 5 308 165 -2.7 0 -2.6 -2.8 12/13/2006 08:00:00 14 1.2 17.2 11.5 13.6 1.1 16.8 10.7 11.7 1.5 16.1 8.4 306 7 302 165 -2.8 0 -2.6 -2.8 12/13/2006 08:10:00 12.6 1.1 15.3 9.5 12.3 1 14.9 8.8 10.7 1.5 14.9 6.8 308 6 314 165 -2.8 0 -2.6 -2.8 12/13/2006 08:20:00 12 1.3 16.1 8.4 11.7 1.3 15.3 8.4 9.1 1.2 13 5.7 302 6 300 165 -2.8 0 -2.6 -3 12/13/2006 08:30:00 13.1 1.6 16.4 8.4 12.8 1.6 16.4 8 10.1 1.7 14.5 6.1 303 7 301 165 -2.9 0 -2.6 -3 12/13/2006 08:40:00 13.3 1.9 17.9 8.8 12.9 1.8 17.9 9.1 10.2 1.7 16.1 6.1 304 6 303 165 -2.9 0 -2.8 -3 12/13/2006 08:50:00 12.9 2 16.8 7.2 12.6 1.9 16.4 7.2 9.8 1.7 14.9 5.7 302 7 307 165 -3 0 -2.8 -3 12/13/2006 09:00:00 13.5 1.7 19.9 8.8 13.2 1.7 19.5 8.8 9.9 1.6 16.8 6.5 301 6 292 165 -2.9 0 -2.8 -3 12/13/2006 09:10:00 12.5 1.7 18.3 8.8 12.3 1.7 18.3 8.8 9.8 1.7 17.2 6.1 304 8 287 165 -3 0 -2.8 -3 12/13/2006 09:20:00 13.3 1.7 17.2 8 13 1.7 17.2 7.6 10 1.5 14.1 5.7 306 6 304 165 -2.9 0 -2.8 -3 12/13/2006 09:30:00 12.7 1.8 17.2 8 12.5 1.8 16.8 7.6 11.4 1.3 16.8 7.2 312 8 300 165 -2.9 0 -2.8 -3 12/13/2006 09:40:00 11.9 1.1 14.5 9.1 11.7 1 14.1 8.8 10.8 1.3 13.7 6.8 311 6 302 165 -2.9 0 -2.8 -3 12/13/2006 09:50:00 12.6 1.1 15.3 9.5 12.3 1.1 14.9 9.5 10.8 1.4 14.9 7.6 309 5 314 165 -3 0 -2.8 -3 12/13/2006 10:00:00 13.8 1.5 17.9 10.3 13.5 1.5 17.6 9.5 12.5 1.8 16.4 8 310 6 313 165 -3 0 -2.8 -3.3 12/13/2006 10:10:00 14 1.3 17.6 11.1 13.7 1.4 17.6 10.3 12.5 1.9 17.2 8 309 7 310 165 -3.2 0 -3 -3.3 12/13/2006 10:20:00 14 1.5 17.6 9.9 13.7 1.5 17.6 9.9 12.4 1.6 16.1 7.2 310 6 310 165 -3.2 0 -3 -3.3 12/13/2006 10:30:00 13.7 1.3 16.1 9.9 13.4 1.3 16.1 9.5 12.2 1.5 15.6 8.4 312 6 307 165 -3.2 0 -3 -3.5 12/13/2006 10:40:00 11.8 1.3 14.9 8 11.5 1.3 14.9 7.2 10.7 1.5 14.5 6.8 314 6 316 165 -3.2 0 -3 -3.5 12/13/2006 10:50:00 12.2 1.3 16.1 8.4 11.9 1.3 15.3 8.8 10.8 1.5 14.9 7.6 310 7 308 165 -3.2 0 -3 -3.5 12/13/2006 11:00:00 14.3 1.7 17.9 9.9 14.1 1.7 17.6 9.1 12.1 1.5 16.4 8.4 307 6 304 165 -3.2 0 -3 -3.5 12/13/2006 11:10:00 15.3 1 17.6 12.2 15 1.1 17.6 11.8 13.3 1.3 16.8 10.3 308 5 305 165 -3.3 0 -3.3 -3.5 12/13/2006 11:20:00 14.9 0.9 17.2 11.5 14.7 0.9 17.2 11.5 11.6 1.3 14.9 8.8 305 4 302 165 -3.3 0 -3.3 -3.5 12/13/2006 11:30:00 14.9 1 17.6 11.5 14.7 1 16.8 11.8 13 1.3 17.6 9.1 308 5 307 165 -3.4 0 -3.3 -3.5 12/13/2006 11:40:00 14.7 0.9 16.4 12.2 14.4 1 16.1 11.8 13.1 1.1 16.8 9.1 309 4 304 165 -3.4 0 -3.3 -3.5 12/13/2006 11:50:00 13.9 1 16.1 11.1 13.6 1.1 16.1 10.7 11.8 1.3 14.9 8.4 308 4 308 165 -3.4 0 -3.3 -3.5 12/13/2006 12:00:00 12.7 0.9 16.1 9.9 12.5 0.9 16.1 9.9 11.3 1.6 15.3 8 310 6 312 165 -3.4 0 -3.3 -3.5 12/13/2006 12:10:00 13.2 1 16.1 10.3 12.9 1 16.1 10.3 12.5 1.3 16.1 8.4 312 6 311 165 -3.4 0 -3.3 -3.5 12/13/2006 12:20:00 13.5 0.9 15.3 10.3 13.3 1 14.9 10.3 12.9 1.2 15.3 8.8 312 4 311 165 -3.3 0 -3.3 -3.5 12/13/2006 12:30:00 12.7 1 14.9 9.9 12.5 1 14.9 10.3 12.6 1 14.9 9.5 313 5 314 165 -3.3 0 -3 -3.5 12/13/2006 12:40:00 13.9 1 16.4 11.1 13.7 0.9 16.4 11.1 13.2 1.2 16.1 9.9 311 4 312 165 -3.3 0 -3 -3.5 12/13/2006 12:50:00 13.8 1.2 17.2 10.7 13.6 1.2 16.8 10.7 13.1 1.2 16.1 8.4 311 4 308 165 -3.3 0 -3 -3.5 12/13/2006 13:00:00 13.9 1.3 17.6 10.7 13.8 1.3 16.8 10.7 13.1 1.3 15.6 8 311 5 307 165 -3.2 0 -3 -3.5 12/13/2006 13:10:00 14.6 1.1 17.6 11.8 14.5 1.1 17.9 11.5 13.1 1.6 16.4 8.8 310 4 301 165 -3.2 0 -3 -3.3 12/13/2006 13:20:00 15 0.8 16.8 12.2 14.8 0.8 16.8 12.2 14 1.2 16.8 10.7 312 3 310 165 -3.2 0 -3 -3.5 12/13/2006 13:30:00 14.7 0.9 16.4 11.5 14.5 0.9 16.4 11.5 14 1 16.8 9.9 312 4 307 165 -3.2 0 -3 -3.3 12/13/2006 13:40:00 14.8 0.9 16.8 12.2 14.6 1 17.2 12.2 13.8 1.1 17.2 10.3 312 4 311 165 -3.2 0 -3 -3.5 12/13/2006 13:50:00 15.1 0.8 17.2 12.6 15 0.8 16.8 12.2 14.6 1 16.8 11.8 312 4 312 165 -3.4 0 -3.3 -3.5 12/13/2006 14:00:00 14.8 1 17.2 11.8 14.7 1 17.2 11.5 13.9 1.4 16.8 10.3 310 5 307 165 -3.5 0 -3.3 -3.5 12/13/2006 14:10:00 15.3 1 17.6 13 15.2 1 17.6 12.6 13.1 1.7 17.2 9.5 305 6 314 165 -3.6 0 -3.5 -3.9 12/13/2006 14:20:00 16.3 1.4 19.5 12.6 16.3 1.4 19.5 11.8 13.1 1.4 16.8 8.8 302 5 298 165 -3.7 0 -3.5 -3.9 12/13/2006 14:30:00 18 1.1 21 14.5 18 1.1 21 14.9 13.9 1.4 18.7 9.5 301 4 303 165 -3.8 0 -3.5 -3.9 12/13/2006 14:40:00 17.9 1.1 20.2 14.9 18 1.1 20.2 14.9 14.5 1.2 18.7 11.1 302 4 302 165 -3.8 0 -3.5 -3.9 12/13/2006 14:50:00 18.5 1.5 21 14.1 18.5 1.5 21.4 13.7 14.1 1.3 17.9 10.7 300 4 296 165 -3.9 0 -3.7 -4.2 12/13/2006 15:00:00 19.8 1 21.4 14.9 19.9 1.1 21.8 14.9 15.4 1.4 19.1 12.2 301 3 297 165 -3.9 0 -3.9 -4.2 12/13/2006 15:10:00 20 1 22.1 17.6 20.2 1 22.1 17.2 15.9 1.6 20.2 12.2 302 5 291 165 -3.9 0 -3.7 -4.2 12/13/2006 15:20:00 19 1.1 21 14.9 19.1 1.1 21 14.9 15.5 1.5 19.9 11.5 303 4 300 165 -3.9 0 -3.7 -4.2 12/13/2006 15:30:00 19.7 1 22.6 16.1 19.8 1 22.6 16.1 14.9 1.3 18.7 11.5 302 3 302 165 -4 0 -3.9 -4.2 12/13/2006 15:40:00 17.9 1.7 21.4 13.3 17.9 1.7 21.8 13.7 14.7 1.9 19.9 9.5 305 6 303 165 -4 0 -3.9 -4.2 12/13/2006 15:50:00 18.7 1.2 21.4 14.5 18.7 1.2 21.4 14.9 14 1.6 18.7 9.5 303 4 302 165 -3.9 0 -3.5 -4.2 12/13/2006 16:00:00 18 1.2 21 13.3 18 1.2 21 13.3 13.4 1.6 18.3 10.3 303 5 301 165 -3.9 0 -3.7 -3.9 12/13/2006 16:10:00 18.3 1.3 21 15.3 18.4 1.3 21 14.9 13.2 1.6 18.3 9.9 302 5 302 165 -3.9 0 -3.5 -3.9 12/13/2006 16:20:00 17.4 1.6 20.2 9.5 17.4 1.6 20.2 9.9 13.1 1.8 19.1 9.5 303 6 297 165 -3.8 0 -3.5 -3.9 12/13/2006 16:30:00 16.3 1.5 19.9 12.2 16.2 1.5 20.2 11.8 12.6 1.8 17.9 8.4 304 6 302 165 -3.8 0 -3.5 -3.9 12/13/2006 16:40:00 15.9 1.1 18.7 13 15.9 1.2 18.7 13 12.5 1.7 17.6 8.8 304 5 301 165 -3.8 0 -3.5 -3.9 12/13/2006 16:50:00 16.4 1.2 19.9 12.6 16.3 1.2 19.9 12.2 12.5 1.6 17.6 9.5 303 6 302 165 -3.8 0 -3.5 -3.9 12/13/2006 17:00:00 16.5 1.5 19.1 12.6 16.5 1.5 19.5 12.2 12.5 1.5 16.4 9.5 303 5 300 165 -3.9 0 -3.7 -4.2 12/13/2006 17:10:00 16 1.2 19.9 13 16 1.2 19.9 13 12.9 1.7 17.9 9.5 305 5 311 165 -4 0.1 -3.9 -4.2 12/13/2006 17:20:00 15.4 1.1 18.3 12.2 15.3 1.1 18.7 12.2 12.6 1.5 16.8 9.1 306 6 299 165 -4.1 0 -3.9 -4.4 12/13/2006 17:30:00 14.5 1.3 17.2 11.1 14.4 1.3 17.2 11.1 12.1 1.5 17.6 8.8 308 5 307 165 -4.2 0 -3.9 -4.6 12/13/2006 17:40:00 14.1 1.3 17.2 11.1 14 1.4 17.2 10.7 11.9 1.6 15.3 8 308 5 302 165 -4.5 0.1 -4.2 -4.6 12/13/2006 17:50:00 12.4 1.5 15.6 8.8 12.2 1.5 15.6 8.4 10.4 1.2 13.7 7.2 307 7 301 165 -4.7 0 -4.4 -4.8 12/13/2006 18:00:00 13.2 1.5 17.2 8.8 13 1.5 17.2 9.1 10.3 1.4 14.5 6.5 303 6 287 165 -4.7 0 -4.4 -4.8 12/13/2006 18:10:00 12.2 1.6 15.6 8 12 1.5 15.6 8 9.8 1.3 13 6.8 304 7 298 165 -4.4 0.1 -4.2 -4.6 12/13/2006 18:20:00 10.6 1.5 14.1 6.8 10.4 1.5 14.1 6.8 8.5 1.5 12.6 4.9 302 9 309 165 -4.4 0 -4.4 -4.6 12/13/2006 18:30:00 12.7 1.3 15.6 9.1 12.6 1.3 15.3 8.8 10.2 1.5 15.6 6.5 305 7 297 165 -4.3 0 -4.2 -4.6 12/13/2006 18:40:00 10.2 1.3 13.7 7.2 10.1 1.3 13.3 6.8 8.4 1.2 11.8 6.1 305 8 294 165 -4.6 0.1 -4.4 -4.8 12/13/2006 18:50:00 11.6 1.8 16.8 8.4 11.5 1.8 17.2 8 9.7 1.6 13.7 6.1 306 8 301 165 -4.7 0 -4.4 -4.8 12/13/2006 19:00:00 13.6 1.3 16.8 9.5 13.5 1.3 16.4 9.1 10.7 1.3 14.9 7.6 304 6 304 165 -4.5 0 -4.4 -4.6 12/13/2006 19:10:00 13.3 1.3 16.4 9.9 13.1 1.3 16.8 9.9 10.5 1.3 14.5 7.6 302 7 305 165 -4.6 0 -4.4 -4.6 12/13/2006 19:20:00 12.4 1.6 16.4 9.1 12.3 1.6 16.4 9.1 10 1.4 15.6 6.8 303 8 301 165 -4.6 0 -4.4 -4.6 12/13/2006 19:30:00 10.7 1.6 15.3 5.3 10.6 1.6 14.5 5.3 8.7 1.5 13.3 5.7 302 9 294 165 -4.7 0 -4.4 -5 12/13/2006 19:40:00 9.5 1.6 14.5 5.7 9.5 1.6 14.5 5.7 7.5 1.5 11.8 4.6 297 11 298 165 -4.8 0 -4.6 -5 12/13/2006 19:50:00 11.5 1.3 14.5 8 11.4 1.3 14.5 8.4 9 1.3 13 5.7 296 8 297 165 -4.8 0 -4.6 -5 12/13/2006 20:00:00 10 1.5 14.1 6.1 9.9 1.5 14.1 6.1 8.4 1.5 13 5.7 303 10 311 165 -4.8 0 -4.6 -5 12/13/2006 20:10:00 10.4 1.5 14.5 5.7 10.4 1.5 14.5 5.7 8.7 1.3 11.8 4.9 306 8 314 165 -5 0 -4.6 -5.3 12/13/2006 20:20:00 11.6 1.5 17.6 8 11.5 1.5 17.2 8.4 9.4 1.4 14.9 6.1 302 9 304 165 -4.9 0 -4.6 -5 12/13/2006 20:30:00 11.8 1.3 14.9 6.8 11.7 1.3 14.5 6.8 9.7 1.3 13.3 6.5 305 8 297 165 -5 0.1 -4.6 -5.5 12/13/2006 20:40:00 11.8 1.4 15.3 7.6 11.7 1.5 14.9 7.6 9.7 1.3 14.1 6.5 305 8 306 165 -5.1 0 -5 -5.3 12/13/2006 20:50:00 11.6 1.2 14.9 8 11.5 1.2 15.3 7.6 9.8 1.2 13 6.5 308 7 307 165 -5.2 0.1 -5 -5.5 12/13/2006 21:00:00 10.6 1.3 14.5 6.8 10.5 1.3 14.5 6.5 9.3 1.4 13.3 5.7 310 9 297 165 -5.5 0 -5.3 -5.7 12/13/2006 21:10:00 10.4 1.3 13.7 6.8 10.3 1.3 14.1 6.8 8.4 1.2 12.2 5.7 303 9 292 165 -5.6 0 -5.5 -5.7 12/13/2006 21:20:00 11.7 1.2 14.5 8 11.6 1.2 14.5 8 9.5 1.3 13.3 6.1 304 8 317 165 -5.6 0 -5.5 -5.7 12/13/2006 21:30:00 10.6 1.4 15.3 7.6 10.5 1.4 15.3 7.2 8.8 1 11.8 5.7 305 8 310 165 -5.7 0 -5.5 -5.7 12/13/2006 21:40:00 11.2 1.2 13.7 8 11.1 1.2 13.7 8 8.7 1 11.5 6.1 302 7 321 165 -5.6 0 -5.5 -5.7 12/13/2006 21:50:00 10.8 1.3 13.7 7.2 10.7 1.3 13.7 7.6 8.5 1.3 11.8 4.9 303 8 292 165 -5.7 0 -5.5 -5.7 12/13/2006 22:00:00 9.2 1.4 13.3 5.3 9.1 1.4 13.3 5.3 7.4 1.2 11.1 4.2 302 8 300 165 -5.8 0 -5.5 -5.9 12/13/2006 22:10:00 10 1.3 13.3 6.8 10 1.3 13.3 6.8 8.1 1.3 11.8 4.9 302 8 306 165 -5.7 0 -5.5 -5.9 12/13/2006 22:20:00 9.7 1.2 12.2 6.1 9.7 1.2 12.2 6.1 7.5 1.1 11.1 4.9 300 7 297 165 -5.6 0 -5.5 -5.7 12/13/2006 22:30:00 10.5 1.2 13.7 7.6 10.5 1.2 13.7 7.6 7.7 1 11.1 5.3 301 6 293 165 -5.8 0 -5.5 -5.9 12/13/2006 22:40:00 9.9 1.1 12.2 7.2 9.9 1.2 12.2 7.2 7.5 1.1 11.1 4.9 300 7 302 165 -5.6 0 -5.5 -5.7 12/13/2006 22:50:00 10.8 0.9 13.7 8 10.9 0.9 13.7 8.4 8.8 1.5 13.3 5.7 292 6 285 165 -5.5 0 -5.3 -5.7 12/13/2006 23:00:00 11.5 0.9 13.3 9.5 11.6 0.9 13.7 9.5 9.6 1.5 12.6 6.5 290 5 287 165 -5.4 0 -5.3 -5.7 12/13/2006 23:10:00 10.7 0.6 12.2 8.8 10.8 0.7 12.2 9.1 9 1.2 11.8 5.7 290 5 292 165 -5.5 0 -5.3 -5.7 12/13/2006 23:20:00 10.4 0.7 12.2 8 10.5 0.7 12.2 7.6 8.8 1.2 11.8 5.7 290 4 286 165 -5.5 0 -5.3 -5.7 12/13/2006 23:30:00 10.5 0.7 12.6 8.4 10.6 0.7 12.6 8.8 8.3 1.2 11.5 5.7 293 5 281 165 -5.3 0 -5 -5.5 12/13/2006 23:40:00 10.5 1 13.7 7.6 10.5 1 13.7 7.6 7.8 1 11.5 5.7 298 6 295 165 -5.3 0 -5 -5.5 12/13/2006 23:50:00 10.9 1.6 16.1 7.6 10.9 1.6 16.1 7.6 8.2 1.2 12.2 5.7 299 7 300 165 -5.2 0 -5 -5.5 12/14/2006 00:00:00 13.2 1.4 17.2 9.9 13.2 1.5 17.2 9.9 10.2 1.5 15.3 7.2 300 8 285 165 -5.1 0 -5 -5.3 12/14/2006 00:10:00 13 1.3 16.1 8.8 12.9 1.3 16.1 8.8 10.1 1.3 14.1 7.2 300 8 303 165 -5.1 0 -4.8 -5.3 12/14/2006 00:20:00 13.4 1.6 17.6 9.1 13.4 1.7 17.6 9.1 10.3 1.5 14.1 7.2 302 8 293 165 -5.2 0.1 -4.8 -5.3 12/14/2006 00:30:00 12.1 1.2 16.4 9.1 11.9 1.2 16.1 9.1 10.2 1.4 14.5 6.5 307 8 307 165 -5.3 0 -5 -5.5 12/14/2006 00:40:00 13.2 1.7 17.2 8.8 13.1 1.7 16.8 8.8 10.6 1.4 16.8 6.8 303 8 289 165 -5.3 0 -5 -5.5 12/14/2006 00:50:00 13.6 1.2 16.8 10.7 13.5 1.2 16.8 10.7 10.8 1.4 15.6 8 303 8 295 165 -5.3 0 -5 -5.5 12/14/2006 01:00:00 13 1.2 16.1 9.9 12.9 1.3 16.8 9.5 10.8 1.6 14.9 6.8 302 8 295 165 -5.3 0 -5 -5.5 12/14/2006 01:10:00 13.9 1.5 17.6 9.9 13.8 1.6 17.6 9.9 11.2 1.9 16.8 7.6 302 9 312 165 -5.3 0 -5 -5.5 12/14/2006 01:20:00 14.6 1.6 18.3 11.1 14.6 1.7 18.3 11.1 11.4 1.5 15.6 8.4 300 8 295 165 -5.3 0 -5 -5.5 12/14/2006 01:30:00 14.9 1.7 19.9 9.9 14.8 1.7 19.9 9.9 11.9 1.5 16.1 8 304 6 300 165 -5.3 0 -5 -5.5 12/14/2006 01:40:00 15.6 1.3 18.3 12.6 15.6 1.4 18.7 11.5 12 1.5 16.8 8.8 301 6 295 165 -5.3 0 -5 -5.5 12/14/2006 01:50:00 15.8 1.2 18.7 12.6 15.8 1.3 18.7 12.6 11.6 1.5 17.2 8.8 297 6 290 165 -5.3 0 -5 -5.5 12/14/2006 02:00:00 17 1.2 20.2 13.7 17 1.2 20.2 13.7 12.7 1.6 16.8 9.5 295 6 293 165 -5.3 0 -5 -5.5 12/14/2006 02:10:00 16.7 1.4 19.9 13 16.7 1.5 19.9 13 13.1 2 19.1 7.6 294 6 294 165 -5.4 0 -5 -5.5 12/14/2006 02:20:00 16.2 1.3 19.9 12.6 16.3 1.4 19.5 12.2 13.3 1.8 17.6 8.8 292 6 296 165 -5.5 0 -5.3 -5.7 12/14/2006 02:30:00 16.5 1 18.7 13.7 16.6 1 19.1 13.7 12.5 1.8 18.3 9.5 294 5 286 165 -5.6 0 -5.5 -5.7 12/14/2006 02:40:00 17 1.1 20.2 14.1 17 1.1 20.2 13.7 12.6 1.4 18.3 9.5 296 5 293 165 -5.6 0 -5.5 -5.7 12/14/2006 02:50:00 16.7 1.3 19.5 13 16.7 1.3 19.5 13 12.6 1.3 16.4 8.8 299 7 299 165 -5.6 0 -5.5 -5.7 12/14/2006 03:00:00 15.9 1.3 20.2 12.2 15.8 1.3 20.2 11.8 12.2 1.3 16.8 8.4 298 8 302 165 -5.6 0 -5.5 -5.7 12/14/2006 03:10:00 17.3 1.7 21 13 17.2 1.7 21 13 15 2.1 19.1 8.8 304 9 303 165 -5.6 0 -5.5 -5.7 12/14/2006 03:20:00 20.1 1.5 23.3 13.7 20 1.5 23.3 14.1 17.7 1.9 21.8 12.2 306 5 301 165 -5.6 0 -5.5 -5.7 12/14/2006 03:30:00 20.8 1.7 24.8 16.1 20.8 1.8 25.2 16.1 18 2.1 22.6 11.8 306 7 304 165 -5.6 0 -5.5 -5.7 12/14/2006 03:40:00 20.2 1.7 24 15.6 20 1.8 24 15.3 19 2.3 25.2 13.3 310 8 305 165 -5.7 0 -5.5 -5.7 12/14/2006 03:50:00 21.6 2 26.3 14.9 21.4 2 26 15.3 21.1 2.3 26 14.1 314 6 318 165 -5.7 0 -5.5 -5.7 12/14/2006 04:00:00 22.8 1.9 27.5 18.3 22.7 1.9 27.5 17.6 22.4 2.2 27.5 16.4 315 5 311 165 -5.6 0 -5.5 -5.7 12/14/2006 04:10:00 22.9 1.9 27.1 18.3 22.7 1.9 26.8 17.6 22.2 2.6 27.1 15.3 314 7 310 165 -5.6 0 -5.5 -5.7 12/14/2006 04:20:00 23.3 1.8 27.9 17.6 23.1 1.9 27.9 17.6 22.9 2.1 27.5 17.6 317 6 316 165 -5.6 0 -5.5 -5.7 12/14/2006 04:30:00 21 1.7 24.8 16.4 20.8 1.7 25.2 16.1 20.2 2.1 26 14.9 314 9 321 165 -5.6 0 -5.5 -5.7 12/14/2006 04:40:00 21.6 1.8 26 16.1 21.4 1.8 26.3 15.3 21.1 2.2 26 13.7 315 8 312 165 -5.5 0 -5.5 -5.7 12/14/2006 04:50:00 21.1 1.9 27.5 16.8 20.9 1.9 27.1 17.2 19.9 2.4 26.8 14.5 314 9 322 165 -5.5 0 -5.3 -5.7 12/14/2006 05:00:00 23.5 1.8 27.9 17.6 23.3 1.9 27.9 17.2 22.3 2.4 28.7 16.8 311 9 314 165 -5.5 0 -5.3 -5.7 12/14/2006 05:10:00 23.9 1.8 29.4 16.4 23.7 1.8 29.4 16.1 23.2 2.2 27.9 16.4 313 8 302 165 -5.6 0 -5.5 -5.7 12/14/2006 05:20:00 26.7 2.3 30.9 20.6 26.6 2.3 31.8 20.2 26.1 2.4 31.8 19.5 312 7 314 165 -5.6 0 -5.5 -5.7 12/14/2006 05:30:00 27.4 2.1 32.9 20.6 27.3 2.2 33.6 20.2 26.6 2.1 33.2 19.9 309 7 306 165 -5.8 0 -5.5 -5.9 12/14/2006 05:40:00 28.6 1.8 34 22.9 28.6 1.9 34.4 23.3 27.4 2.3 33.6 19.5 307 7 301 165 -5.9 0 -5.7 -6.1 12/14/2006 05:50:00 29.6 2.9 36.7 22.1 29.6 3.1 36.7 22.1 28.6 3.2 36.7 19.5 307 7 309 165 -6.1 0 -5.7 -6.4 12/14/2006 06:00:00 30.4 2.5 37.8 23.3 30.4 2.5 37.8 23.7 29.5 2.5 37.8 23.7 308 8 310 165 -6.2 0 -5.9 -6.4 12/14/2006 06:10:00 30.6 2.5 36.7 24 30.5 2.5 36.3 24.4 30.1 2.5 37.5 22.9 313 9 329 165 -6.1 0 -5.9 -6.4 12/14/2006 06:20:00 32.9 2.7 40.1 26 32.8 2.7 39.8 26 32.7 2.8 40.1 26 316 8 312 165 -6.1 0 -5.7 -6.4 12/14/2006 06:30:00 33.2 2.8 42.1 27.1 33.1 2.8 42.4 26.3 32.8 3.1 42.4 26 317 7 316 165 -6.1 0 -5.7 -6.4 12/14/2006 06:40:00 32 2.6 39.8 23.3 31.8 2.6 38.6 22.6 31.7 2.7 38.6 23.7 320 7 320 165 -6 0 -5.7 -6.1 12/14/2006 06:50:00 33 2.8 39.4 22.1 32.9 2.8 40.1 23.3 32.8 3.1 39 24 321 7 319 165 -6 0 -5.7 -6.1 12/14/2006 07:00:00 31.9 2.9 39.8 22.6 31.7 3.1 39.8 22.6 31.8 3.3 39 23.3 322 6 317 165 -5.9 0 -5.7 -6.1 12/14/2006 07:10:00 29.4 2.8 35.9 21.4 29.1 2.8 35.5 21.4 29 2.9 35.9 19.9 323 7 321 165 -5.9 0 -5.7 -6.1 12/14/2006 07:20:00 31.1 2.9 36.7 21.8 31 2.9 36.7 21.8 30.8 3.2 37.1 17.9 322 9 325 165 -5.8 0 -5.5 -6.1 12/14/2006 07:30:00 29.2 2.8 37.5 22.6 29 2.8 37.1 22.6 29.1 2.9 35.5 23.3 323 7 317 165 -5.6 0 -5.5 -5.7 12/14/2006 07:40:00 27.8 2.7 35.2 19.5 27.6 2.8 34.8 19.5 27.5 2.9 36.3 19.5 320 8 312 165 -5.6 0 -5.5 -5.7 12/14/2006 07:50:00 28.9 2.4 35.5 22.9 28.7 2.4 35.9 23.3 28.8 2.6 35.9 22.9 323 7 333 165 -5.6 0 -5.3 -5.7 12/14/2006 08:00:00 29.1 1.9 33.6 24 28.8 1.9 34 22.9 28.7 2.1 34.8 19.9 321 5 311 165 -5.5 0 -5.3 -5.7 12/14/2006 08:10:00 29.6 2.2 35.2 24 29.4 2.3 35.2 24 29.5 2.5 35.9 22.6 319 5 313 165 -5.5 0 -5.3 -5.7 12/14/2006 08:20:00 31.2 2.8 38.2 22.1 31.1 2.9 38.6 22.1 31 3.2 38.2 21.4 320 6 320 165 -5.6 0 -5.5 -5.9 12/14/2006 08:30:00 30.6 2.4 36.3 22.9 30.4 2.4 36.3 23.3 30.4 2.7 37.1 20.6 322 6 319 165 -5.8 0 -5.5 -5.9 12/14/2006 08:40:00 28.5 2.5 34.8 21.8 28.2 2.5 34.8 21.4 28.2 2.8 35.2 20.6 321 7 319 165 -5.6 0 -5.5 -5.7 12/14/2006 08:50:00 28.6 2.5 34.8 21.4 28.3 2.5 34.4 20.6 28.3 2.6 34.8 21.4 321 7 313 165 -5.5 0 -5.3 -5.7 12/14/2006 09:00:00 29.8 2.2 34.8 19.9 29.5 2.3 34.8 19.9 29.6 2.6 36.7 20.2 320 5 319 165 -5.4 0 -5.3 -5.7 12/14/2006 09:10:00 28.9 2.1 33.6 22.1 28.6 2.1 32.9 21.4 28.7 2.4 34.4 19.1 321 5 322 165 -5.3 0 -5 -5.5 12/14/2006 09:20:00 27.4 2.2 32.9 21.8 27.3 2.2 32.9 21.8 27.4 2.4 32.9 21.8 321 7 316 165 -5.3 0 -5 -5.5 12/14/2006 09:30:00 26.9 2.3 32.9 20.2 26.7 2.3 32.1 20.6 26.7 2.6 33.2 20.2 318 7 323 165 -5.3 0 -5 -5.5 12/14/2006 09:40:00 27.9 2 32.4 21.8 27.7 2 32.1 22.1 27.8 2.4 33.6 19.1 320 5 322 165 -5.2 0 -5 -5.5 12/14/2006 09:50:00 28.3 1.8 32.1 22.9 28.2 1.9 32.1 22.1 28.3 2.2 33.6 21.8 319 6 315 165 -5.3 0 -5 -5.5 12/14/2006 10:00:00 25.8 1.9 29.4 19.9 25.6 1.9 29.1 20.2 25.9 2.1 30.6 19.9 322 5 330 165 -5.4 0 -5 -5.7 12/14/2006 10:10:00 27.3 2 33.6 21.4 27.1 2 33.2 21.4 27 2.3 32.9 20.2 320 5 319 165 -5.3 0 -5 -5.5 12/14/2006 10:20:00 27 1.9 30.9 17.9 26.9 1.9 30.6 17.9 26.7 2.3 31.8 18.3 318 5 328 165 -5.3 0 -5 -5.5 12/14/2006 10:30:00 25.5 2.5 30.9 19.1 25.3 2.5 30.6 19.1 25 2.7 30.9 17.2 318 6 314 165 -5.3 0 -5 -5.5 12/14/2006 10:40:00 24.4 2.1 29.8 19.1 24.1 2.1 29.1 18.7 24.1 2.3 30.9 17.9 323 6 334 165 -5.2 0 -5 -5.5 12/14/2006 10:50:00 25.3 2.4 29.1 16.4 25.1 2.4 29.1 16.4 24.5 2.6 28.3 16.1 316 6 312 165 -5.1 0 -4.8 -5.3 12/14/2006 11:00:00 24.8 1.9 29.1 18.7 24.6 1.9 29.1 19.1 24.1 2.2 28.7 17.6 317 5 313 165 -5.3 0 -5 -5.5 12/14/2006 11:10:00 24.3 2.8 29.1 16.1 24.1 2.9 29.1 15.6 23.6 3.2 29.8 14.5 317 6 318 165 -5.2 0 -5 -5.5 12/14/2006 11:20:00 20.8 2.9 26.8 13 20.5 2.9 26.3 13 19.9 3.3 26.3 9.5 319 7 316 165 -4.9 0.1 -4.6 -5.3 12/14/2006 11:30:00 20.3 2.5 26.3 11.8 20 2.5 25.6 12.2 19.4 2.6 26.8 13.3 319 8 321 165 -5 0.1 -4.4 -5.3 12/14/2006 11:40:00 21.6 2.8 28.3 15.3 21.4 2.8 28.3 14.9 20.7 3.2 28.3 13 318 8 316 165 -5.3 0 -5 -5.5 12/14/2006 11:50:00 21.8 2.2 27.1 15.3 21.5 2.2 26.8 15.3 21 2.4 27.1 14.1 319 8 317 165 -5.3 0 -5 -5.7 12/14/2006 12:00:00 21.8 2.7 29.1 14.5 21.5 2.7 28.7 14.9 21.1 3.1 26.8 12.2 319 8 317 165 -5.5 0 -5.3 -5.7 12/14/2006 12:10:00 22.2 2.1 26.3 16.1 21.9 2.1 26.3 15.3 21.6 2.3 27.1 15.6 319 7 316 165 -5.3 0.1 -5 -5.5 12/14/2006 12:20:00 22.5 2.6 28.3 15.3 22.3 2.5 27.9 16.1 22 2.7 27.5 15.3 319 7 321 165 -5.3 0 -5 -5.5 12/14/2006 12:30:00 20.9 2.4 27.9 14.5 20.6 2.4 27.5 13.7 20.4 2.6 27.5 13.3 319 8 318 165 -5.3 0 -5 -5.5 12/14/2006 12:40:00 20.4 2.5 26.8 14.1 20.1 2.4 26.3 13.7 19.6 2.7 26.8 12.2 321 7 319 165 -5.3 0 -5 -5.5 12/14/2006 12:50:00 18.2 2.7 24.4 9.5 18 2.6 23.7 9.5 17.3 2.8 24.4 8.8 325 10 312 165 -5.3 0 -5 -5.7 12/14/2006 13:00:00 19.1 2.4 27.5 11.8 18.9 2.4 27.1 12.2 18.2 2.6 26.8 10.7 322 9 316 165 -5.3 0 -5 -5.5 12/14/2006 13:10:00 19.5 2.3 24.8 11.5 19.3 2.3 24.8 11.8 19.1 2.5 25.2 11.1 321 8 317 165 -5.3 0 -5 -5.5 12/14/2006 13:20:00 18.6 2.2 26 12.6 18.5 2.1 25.2 12.6 18.5 2.2 24.4 12.2 319 8 321 165 -5.3 0 -5 -5.5 12/14/2006 13:30:00 20.5 2.4 24.8 14.1 20.3 2.4 24.8 14.1 20 2.6 24.8 13 319 8 316 165 -5.3 0 -5 -5.5 12/14/2006 13:40:00 18.8 2.2 24 13 18.6 2.2 23.3 13 18 2.3 22.9 11.1 317 9 317 165 -5.3 0 -5 -5.5 12/14/2006 13:50:00 16 1.8 20.6 9.9 15.9 1.8 20.2 10.3 15.3 2.1 19.9 10.7 319 10 303 165 -5.2 0 -5 -5.3 12/14/2006 14:00:00 17 1.8 22.1 12.6 16.8 1.8 21.8 12.2 15.9 2.1 20.6 11.1 315 7 316 165 -5.1 0 -4.8 -5.3 12/14/2006 14:10:00 15.4 2.3 20.6 8.4 15.3 2.2 20.2 8.4 14.5 2.3 19.1 8.4 317 11 310 165 -5.3 0.1 -4.8 -5.5 12/14/2006 14:20:00 17.5 2.7 23.3 9.1 17.4 2.7 22.9 9.9 17 2.7 23.7 9.5 321 9 316 165 -5.5 0 -5.3 -5.7 12/14/2006 14:30:00 18.1 2.3 24.4 12.6 17.8 2.3 24 12.6 17.5 2.6 24 11.8 322 9 316 165 -5.6 0 -5.3 -5.7 12/14/2006 14:40:00 18.5 1.9 23.7 12.6 18.2 1.9 23.3 12.2 18 2 26.3 13.3 322 9 319 165 -5.7 0 -5.5 -5.7 12/14/2006 14:50:00 18.9 2.8 24.8 11.5 18.8 2.8 24.8 11.1 18.6 2.9 25.6 11.1 320 9 316 165 -5.8 0 -5.5 -5.7 12/14/2006 15:00:00 19.3 2.4 24 10.7 19.1 2.4 24 10.7 18.7 2.4 24 11.1 319 7 320 165 -5.8 0 -5.5 -5.9 12/14/2006 15:10:00 19 2.1 23.3 12.2 18.9 2.1 23.3 12.2 18.6 2.4 23.3 10.7 316 6 302 165 -5.8 0.1 -5.5 -5.9 12/14/2006 15:20:00 19.6 2 24.8 14.1 19.4 2 24.4 14.5 19.2 2.3 24 11.8 317 6 305 165 -5.8 0 -5.5 -5.9 12/14/2006 15:30:00 17.2 2.1 22.1 12.6 17 2.1 22.1 12.6 16.1 2.2 21.8 10.3 316 8 311 165 -5.8 0 -5.5 -5.9 12/14/2006 15:40:00 18.9 2.2 26.8 11.8 18.7 2.2 26.3 11.5 18.6 2.4 24.8 10.7 320 9 314 165 -5.8 0 -5.7 -5.9 12/14/2006 15:50:00 17.2 2.1 22.6 11.5 17 2.1 23.3 11.1 16.8 2.1 22.6 11.5 320 9 314 165 -5.8 0 -5.7 -5.9 12/14/2006 16:00:00 19.1 2 23.3 13.7 18.8 2 23.3 13.7 18.3 2.1 24 11.8 318 9 322 165 -6 0 -5.7 -6.1 12/14/2006 16:10:00 20.9 2.2 25.2 13.7 20.6 2.2 25.2 13.7 20.4 2.5 25.2 12.6 318 8 296 165 -6.1 0 -5.7 -6.4 12/14/2006 16:20:00 19.9 2.5 24.8 12.2 19.7 2.5 24.4 12.2 19.5 2.6 25.6 12.2 319 9 324 165 -6.2 0 -5.9 -6.4 12/14/2006 16:30:00 20.4 2.1 26 14.5 20.1 2.1 25.6 14.9 19.9 2.4 25.6 13.3 320 8 312 165 -6.2 0 -5.9 -6.4 12/14/2006 16:40:00 21.6 2 28.7 14.9 21.4 2 28.3 15.3 21.2 2 26.8 14.1 319 7 312 165 -6.2 0 -6.1 -6.4 12/14/2006 16:50:00 20 2.6 25.2 13.7 19.8 2.6 24.8 13.7 19.4 2.9 25.6 11.8 320 8 330 165 -6.3 0 -5.9 -6.6 12/14/2006 17:00:00 20.9 2.5 27.1 13.3 20.7 2.5 26.8 13.3 20.4 2.8 27.9 11.5 322 9 319 165 -6.3 0 -6.1 -6.6 12/14/2006 17:10:00 20.2 2.1 25.6 14.9 20 2.1 26 14.9 19.9 2.6 26.3 13.3 318 8 316 165 -6.4 0 -6.1 -6.6 12/14/2006 17:20:00 19.2 2.5 27.1 13.3 19 2.4 27.1 13.3 18.7 2.7 26.8 12.2 318 8 312 165 -6.4 0 -6.1 -6.6 12/14/2006 17:30:00 18.8 2.5 24.4 13.3 18.6 2.5 24.4 12.2 18.5 2.6 25.2 12.6 323 8 324 165 -6.4 0 -6.1 -6.6 12/14/2006 17:40:00 18 2.6 24.4 12.2 17.7 2.5 24 12.2 17.3 2.7 24 11.5 320 9 325 165 -6.5 0 -6.4 -6.8 12/14/2006 17:50:00 18.3 2.2 24.8 10.7 18.1 2.2 24.4 11.1 17.8 2.5 25.2 11.8 321 10 326 165 -6.5 0 -6.4 -6.8 12/14/2006 18:00:00 17.4 2.3 23.3 12.6 17.2 2.3 22.9 12.2 16.8 2.4 23.3 11.8 321 9 328 165 -6.6 0 -6.4 -6.8 12/14/2006 18:10:00 18.4 2.2 22.9 13 18.2 2.2 22.6 12.6 17.3 2.4 23.3 10.7 315 11 331 165 -6.5 0 -6.1 -6.8 12/14/2006 18:20:00 15.9 1.9 20.2 10.3 15.7 1.8 20.2 10.3 14.6 2 19.5 9.5 317 10 292 165 -6.5 0 -6.1 -6.8 12/14/2006 18:30:00 14.5 2.4 20.6 7.6 14.3 2.4 19.9 7.6 13.7 2.6 20.2 7.2 322 12 323 165 -6.5 0 -6.4 -6.8 12/14/2006 18:40:00 13.5 2.5 19.9 7.6 13.3 2.5 19.9 7.2 12.6 2.6 19.5 6.8 321 12 318 165 -6.5 0 -6.4 -6.8 12/14/2006 18:50:00 14.9 2.9 22.9 8.4 14.7 2.8 21.8 8 13.9 2.8 19.9 8.8 319 12 301 165 -6.5 0 -6.1 -6.8 12/14/2006 19:00:00 12.1 2 16.4 6.8 12 2 16.4 6.1 11.1 2.2 17.6 4.6 317 14 302 165 -6.4 0 -5.9 -6.6 12/14/2006 19:10:00 12.9 2.2 19.1 6.5 12.7 2.2 18.7 6.5 11.6 2.2 17.2 6.1 313 12 312 165 -6.4 0 -6.1 -6.6 12/14/2006 19:20:00 11 2.4 16.1 6.1 10.8 2.5 16.4 5.3 10.1 2.3 16.1 5.3 323 17 310 165 -6.4 0 -6.1 -6.6 12/14/2006 19:30:00 12 2.3 18.7 6.1 11.8 2.2 19.5 6.8 10.9 2.3 18.3 6.1 312 11 305 165 -6.2 0 -5.9 -6.4 12/14/2006 19:40:00 13 2.4 19.5 7.2 12.8 2.4 19.5 8 11.9 2.2 18.7 6.5 314 11 319 165 -6.2 0 -5.9 -6.4 12/14/2006 19:50:00 13.8 1.8 19.1 8.8 13.5 1.8 19.1 9.1 12.7 2 17.6 7.6 316 11 317 165 -6.4 0 -6.1 -6.6 12/14/2006 20:00:00 14.8 1.6 20.2 11.1 14.6 1.6 20.2 11.5 13.5 1.7 18.3 8.8 314 10 313 165 -6.5 0 -6.4 -6.8 12/14/2006 20:10:00 13.8 2.4 19.5 7.2 13.7 2.4 19.1 7.2 12.8 2.4 19.5 6.8 313 11 313 165 -6.6 0 -6.4 -6.8 12/14/2006 20:20:00 13.8 2 18.7 9.1 13.7 2 18.7 8.4 12.2 1.7 16.4 7.2 313 11 297 165 -6.7 0 -6.6 -6.8 12/14/2006 20:30:00 15 2.1 20.6 8.4 14.9 2 20.2 8.8 14.1 1.9 19.9 9.5 315 9 318 165 -6.7 0 -6.6 -6.8 12/14/2006 20:40:00 16.4 1.8 20.6 11.5 16.3 1.8 20.2 11.1 15.3 2.2 20.2 9.9 313 8 305 165 -6.7 0 -6.6 -6.8 12/14/2006 20:50:00 15.3 1.8 19.1 9.9 15.1 1.7 19.1 9.5 14 2.3 19.1 8 309 9 313 165 -6.8 0 -6.6 -7 12/14/2006 21:00:00 16 1.5 19.9 11.5 15.8 1.5 20.2 11.8 14.9 1.6 20.2 9.5 312 7 310 165 -6.8 0 -6.6 -6.8 12/14/2006 21:10:00 15.9 1.6 19.9 11.8 15.8 1.6 20.2 11.5 14.3 1.9 19.1 9.9 309 9 309 165 -6.8 0 -6.6 -7 12/14/2006 21:20:00 16.5 1.7 21.8 12.6 16.4 1.8 21.4 12.6 14.6 2.2 19.9 9.1 307 8 291 165 -6.8 0 -6.6 -7 12/14/2006 21:30:00 16.7 2.4 23.3 12.6 16.6 2.4 23.3 12.2 14.1 2.4 19.9 8.8 303 9 300 165 -6.8 0 -6.6 -7 12/14/2006 21:40:00 16.6 2 21.8 11.8 16.6 2 21.8 11.8 13.6 2.2 20.6 8.8 298 10 306 165 -6.7 0 -6.6 -6.8 12/14/2006 21:50:00 16.2 2 21 10.7 16.2 2.1 21 10.3 13.5 2.3 18.7 8 292 9 288 165 -6.7 0 -6.6 -6.8 12/14/2006 22:00:00 15.3 1.9 20.6 10.3 15.2 1.9 20.6 10.3 12.5 2.1 18.3 8 297 12 294 165 -6.7 0 -6.6 -6.8 12/14/2006 22:10:00 18 2.3 22.6 11.8 18 2.4 22.9 11.1 14.8 2.2 22.6 8 297 11 286 165 -6.7 0.1 -6.4 -6.8 12/14/2006 22:20:00 16.6 2.3 21.8 11.1 16.6 2.4 21.8 10.3 13.5 2.5 22.1 8.8 295 9 289 165 -6.6 0 -6.4 -6.8 12/14/2006 22:30:00 16.4 1.7 22.6 12.6 16.4 1.7 22.1 12.2 13.3 2 19.1 8.8 297 10 298 165 -6.7 0 -6.6 -6.8 12/14/2006 22:40:00 16.3 2.4 23.3 11.1 16.3 2.4 23.7 11.1 13.5 2.6 20.6 8.4 299 9 299 165 -6.7 0 -6.6 -6.8 12/14/2006 22:50:00 18.5 2 23.7 12.6 18.4 2 23.7 12.2 15 2.5 22.1 9.5 301 9 310 165 -6.8 0 -6.6 -7 12/14/2006 23:00:00 19.6 1.8 25.2 14.9 19.5 1.8 24 14.5 15.9 2.2 21 10.7 301 9 298 165 -6.9 0 -6.6 -7 12/14/2006 23:10:00 20.9 2 25.2 16.1 20.8 2 25.6 15.6 17.8 2.3 24.4 12.2 302 8 296 165 -6.9 0 -6.6 -7 12/14/2006 23:20:00 22.7 1.8 27.9 17.2 22.6 1.9 27.9 17.2 19.7 2.2 24.8 14.1 303 9 296 165 -7.1 0 -6.8 -7.2 12/14/2006 23:30:00 24.4 1.9 29.8 18.7 24.3 2 29.8 18.3 22.8 2.4 28.3 16.4 305 9 301 165 -7.3 0.1 -7 -7.4 12/14/2006 23:40:00 23.2 2 28.3 18.3 23.1 2 27.9 17.9 22 2.5 27.1 14.9 307 9 304 165 -7.5 0 -7.2 -7.6 12/14/2006 23:50:00 22.7 2.4 29.4 17.2 22.7 2.4 29.1 17.2 20.5 2.7 27.5 13.7 303 9 301 165 -7.5 0 -7.2 -7.6 12/15/2006 00:00:00 22.3 2.6 28.3 14.1 22.2 2.6 28.7 14.5 18.3 2.5 26.3 12.6 297 10 277 165 -7.5 0 -7.2 -7.6 12/15/2006 00:10:00 22.8 1.9 27.5 17.6 22.8 2 27.5 16.4 18.2 2.3 26.3 11.8 293 9 297 165 -7.4 0 -7.2 -7.6 12/15/2006 00:20:00 22.3 2.3 26.8 16.1 22.3 2.4 27.5 16.1 17.8 2.6 26 13.3 295 11 302 165 -7.4 0 -7.2 -7.6 12/15/2006 00:30:00 23.2 2 27.5 17.2 23.2 2 27.9 17.2 18.8 2.4 24.8 13 297 9 287 165 -7.4 0 -7.2 -7.4 12/15/2006 00:40:00 21.8 2.2 26.8 15.6 21.7 2.2 27.1 14.9 17.5 2.2 24 13 295 11 291 165 -7.4 0 -7.2 -7.6 12/15/2006 00:50:00 21.3 2.4 26 13.7 21.3 2.4 25.6 14.5 16.5 2.2 24 11.8 295 8 296 165 -7.3 0.1 -6.8 -7.4 12/15/2006 01:00:00 21.9 2.1 27.1 16.1 21.9 2.1 27.1 16.1 16.8 2.2 23.7 12.2 295 7 291 165 -7.4 0 -7.2 -7.6 12/15/2006 01:10:00 21.8 2.2 27.5 15.6 21.8 2.3 27.5 15.6 17.9 2.8 25.6 10.3 298 10 290 165 -7.5 0 -7.2 -7.6 12/15/2006 01:20:00 18.7 1.9 23.3 13.7 18.7 2 23.7 13.7 15.7 2.5 23.3 10.3 301 10 307 165 -7.5 0 -7.2 -7.6 12/15/2006 01:30:00 18.9 1.5 22.9 14.9 18.8 1.6 22.6 14.9 16.6 2.3 22.1 12.2 302 11 286 165 -7.5 0 -7.2 -7.6 12/15/2006 01:40:00 18.9 1.9 25.2 14.5 18.9 1.9 24.8 14.5 15.5 2.4 21.8 9.9 299 10 295 165 -7.5 0 -7.4 -7.6 12/15/2006 01:50:00 18.4 1.7 23.3 14.1 18.4 1.7 22.9 14.1 15.3 2.1 20.6 10.3 297 10 300 165 -7.5 0 -7.4 -7.6 12/15/2006 02:00:00 17.7 1.9 22.9 13 17.6 2 22.9 13 13.9 2 20.2 9.9 297 10 292 165 -7.5 0 -7.2 -7.6 12/15/2006 02:10:00 15.9 2 22.1 11.5 15.8 2 22.1 11.5 14.4 2.4 22.9 8.8 309 10 314 165 -7.6 0 -7.4 -7.9 12/15/2006 02:20:00 15.4 1.5 20.2 11.1 15.2 1.5 19.9 11.1 14.5 2 19.9 9.1 313 9 314 165 -7.6 0 -7.4 -7.9 12/15/2006 02:30:00 15.7 2 19.9 10.3 15.5 2 19.5 10.7 14.9 2 20.2 9.5 314 8 321 165 -7.6 0 -7.4 -7.9 12/15/2006 02:40:00 16.8 1.8 20.2 11.8 16.6 1.8 20.2 12.2 15.5 2.1 20.2 10.7 310 8 309 165 -7.5 0 -7.2 -7.6 12/15/2006 02:50:00 17 2 20.6 12.2 16.8 2 20.6 12.2 16.2 2.1 20.6 11.1 315 8 307 165 -7.5 0 -7.2 -7.6 12/15/2006 03:00:00 17 1.8 21 10.3 16.8 1.7 19.9 11.1 16.3 2.1 21 10.3 314 8 318 165 -7.6 0 -7.4 -7.6 12/15/2006 03:10:00 16.1 2.3 22.1 10.3 15.9 2.3 21.8 11.1 15.1 2.1 19.5 8.4 315 9 311 165 -7.8 0.1 -7.4 -8.1 12/15/2006 03:20:00 17.6 2 21.8 10.7 17.4 2 21.4 10.7 16.5 2.2 21.8 9.5 313 10 298 165 -8 0 -7.6 -8.1 12/15/2006 03:30:00 17.5 2.5 23.7 11.1 17.3 2.4 23.7 10.7 16.3 2.7 22.1 10.3 316 10 315 165 -8 0 -7.6 -8.1 12/15/2006 03:40:00 18.2 2 24 12.2 17.9 1.9 23.3 11.8 17.4 2.3 23.7 11.5 316 9 325 165 -7.9 0 -7.6 -8.1 12/15/2006 03:50:00 16.2 2.5 22.1 9.5 16 2.5 21.8 9.5 15.2 2.5 22.1 9.5 318 12 314 165 -8 0.1 -7.6 -8.3 12/15/2006 04:00:00 17.2 1.8 22.1 12.2 16.9 1.8 21.4 11.8 15.4 1.8 20.2 10.3 310 11 298 165 -8.2 0 -8.1 -8.5 12/15/2006 04:10:00 16.4 2.6 23.7 10.7 16.3 2.5 23.7 10.7 15.1 2.5 21.4 9.5 318 14 317 165 -8.3 0 -8.1 -8.5 12/15/2006 04:20:00 19.5 2.7 26 11.5 19.3 2.7 25.2 11.1 18.6 2.9 25.2 11.5 315 10 322 165 -8 0.1 -7.6 -8.3 12/15/2006 04:30:00 18 2.2 23.7 12.2 17.9 2.2 23.3 12.6 16.4 2.5 23.7 10.3 313 11 307 165 -8 0 -7.6 -8.1 12/15/2006 04:40:00 17.6 2.5 23.7 9.9 17.4 2.5 23.7 10.3 15.8 2.8 22.1 8.8 313 13 316 165 -7.9 0 -7.6 -8.1 12/15/2006 04:50:00 18 2.3 23.7 11.5 17.8 2.2 23.7 12.2 16.7 2.5 21.4 8.4 315 10 311 165 -7.6 0.1 -7.2 -8.1 12/15/2006 05:00:00 17.8 2.6 23.3 9.9 17.6 2.5 23.3 11.5 16.4 3.1 22.9 9.5 316 10 302 165 -7.6 0 -7.2 -7.9 12/15/2006 05:10:00 18.2 1.9 22.6 12.6 17.9 1.9 22.6 12.2 17.2 2.2 23.3 9.5 317 8 319 165 -7.6 0 -7.4 -7.9 12/15/2006 05:20:00 12.7 1.8 17.2 8.4 12.5 1.8 17.2 8 11.8 1.8 16.4 7.2 319 11 312 165 -7.8 0 -7.4 -8.1 12/15/2006 05:30:00 10.1 2.1 14.9 5.3 10 2 14.9 5.3 8.9 1.9 13.7 4.6 314 13 298 165 -7.9 0 -7.6 -8.1 12/15/2006 05:40:00 11.6 1.4 14.9 8.4 11.5 1.4 14.9 8.4 10.5 1.4 14.5 7.2 312 11 312 165 -7.7 0.1 -7.4 -8.1 12/15/2006 05:50:00 9.9 1.1 13.3 6.8 9.8 1.2 13 6.5 9.3 1.1 12.2 5.7 314 10 306 165 -7.8 0 -7.4 -8.1 12/15/2006 06:00:00 10.1 2.2 14.1 3.8 9.9 2.2 14.1 3.8 9.2 2.1 14.1 4.2 314 13 316 165 -7.6 0 -7.4 -7.9 12/15/2006 06:10:00 9.2 1.5 14.1 6.1 9.1 1.5 14.1 6.1 7.8 1.7 12.2 3.8 306 11 312 165 -7.5 0 -7.4 -7.6 12/15/2006 06:20:00 7.7 1.4 11.8 4.2 7.6 1.4 11.5 4.9 6.8 1.3 10.7 3.4 295 13 303 165 -7.5 0 -7.2 -7.6 12/15/2006 06:30:00 8.1 1.3 11.8 4.9 8.1 1.3 11.8 4.6 6.8 1.2 10.7 3.8 299 10 282 165 -7.5 0 -7.2 -7.6 12/15/2006 06:40:00 9.2 1.3 12.2 6.1 9.1 1.3 12.6 5.7 8 1.5 11.8 4.6 298 11 282 165 -7.6 0 -7.2 -7.6 12/15/2006 06:50:00 10.5 1 13.3 8 10.5 1 13.3 8 8.6 1.3 12.2 5.3 291 7 291 165 -7.4 0 -7.2 -7.6 12/15/2006 07:00:00 9.5 1.1 11.8 6.5 9.6 1.1 11.8 6.1 7.9 1.3 11.5 4.9 290 8 297 165 -7.2 0 -7 -7.4 12/15/2006 07:10:00 9 1.3 12.2 5.3 9.1 1.3 12.6 5.7 8 1.5 12.6 4.6 287 6 276 165 -7.2 0 -6.8 -7.4 12/15/2006 07:20:00 6.3 1.3 10.3 3.8 6.5 1.2 9.9 4.2 5.9 1.2 9.1 3.8 284 9 281 165 -7.3 0.1 -6.8 -7.4 12/15/2006 07:30:00 5.7 0.6 7.2 4.2 5.7 0.6 7.2 4.2 5.5 0.6 7.2 3.8 285 5 286 165 -7.5 0 -7.2 -7.6 12/15/2006 07:40:00 4.2 0.6 5.7 2.6 4.6 0.5 5.7 3.4 4.2 0.5 5.7 3 276 5 280 165 -7.6 0 -7.4 -7.6 12/15/2006 07:50:00 3.9 1.4 7.6 1.5 4.5 1.5 9.1 2.3 4 1.5 8.4 1.9 270 10 265 165 -7.4 0.2 -6.8 -7.6 12/15/2006 08:00:00 2.7 0.9 4.6 0.7 3 1 5.7 1.1 2.3 0.9 5.7 0.4 263 20 263 165 -7.9 0 -7.4 -8.1 12/15/2006 08:10:00 2.2 0.5 3.8 1.1 2.5 0.5 3.8 1.1 2.1 0.6 3.4 0.4 253 13 242 165 -8 0.1 -7.6 -8.3 12/15/2006 08:20:00 3.8 0.6 5.3 1.9 3.9 0.5 5.3 2.3 3.3 0.5 4.6 1.5 287 13 292 165 -7.7 0.1 -7.4 -8.1 12/15/2006 08:30:00 6.4 1 8.4 4.6 6.3 1 8.4 4.6 5.6 1.1 8 3 310 8 292 165 -7.5 0.2 -7.2 -8.1 12/15/2006 08:40:00 4.9 1.5 8 1.9 5 1.3 7.6 2.6 4.3 1 7.2 2.6 284 20 301 165 -7.4 0.2 -6.8 -8.1 12/15/2006 08:50:00 5.1 0.8 6.8 2.3 5.2 0.7 6.8 3 4.6 0.8 6.8 2.3 288 9 279 165 -7.5 0.2 -7 -8.1 12/15/2006 09:00:00 4.7 0.7 6.1 2.6 5.1 0.6 6.8 3 4.7 0.7 6.8 2.6 276 8 283 165 -7.2 0.2 -6.8 -7.4 12/15/2006 09:10:00 6 0.8 7.6 3.4 6 0.7 7.6 4.2 5.4 0.7 7.6 3.4 288 9 292 165 -6.8 0.2 -6.6 -7.2 12/15/2006 09:20:00 3.8 0.7 5.3 1.9 4.5 0.5 6.1 3.4 4.3 0.4 5.7 3 259 9 249 165 -7.1 0 -6.8 -7.4 12/15/2006 09:30:00 4 0.7 5.3 1.9 4.4 0.4 5.3 3.4 4.2 0.4 4.9 3.4 248 13 249 165 -7.4 0.1 -7.2 -7.6 12/15/2006 09:40:00 3.1 0.6 4.2 1.5 3.1 0.6 4.6 1.5 3.1 0.6 4.6 1.9 231 7 234 165 -7.2 0.1 -6.8 -7.4 12/15/2006 09:50:00 1.7 0.8 3.8 0.4 1.6 0.8 3.8 0.4 1.6 0.6 3.4 0.4 222 18 250 165 -6.9 0 -6.8 -7 12/15/2006 10:00:00 1.6 0.9 4.2 0.4 1.6 0.9 3.8 0.4 1.7 1 3.8 0.4 221 15 245 165 -6.7 0 -6.4 -7 12/15/2006 10:10:00 2.1 0.7 3.4 0.4 2 0.6 3.4 0.4 2 0.7 3 0.4 192 36 165 165 -6.9 0 -6.6 -7.2 12/15/2006 10:20:00 2 0.5 2.6 0.7 1.9 0.5 2.6 1.1 2.2 0.5 3 1.1 163 7 154 165 -6.9 0.2 -6.6 -7.2 12/15/2006 10:30:00 1.9 0.9 3 0.4 1.9 0.8 3 0.4 2 0.8 3.4 0.7 153 7 159 165 -6.6 0 -6.4 -6.8 12/15/2006 10:40:00 2.5 0.7 4.2 1.5 2.5 0.7 3.8 1.5 2.6 0.6 4.2 1.5 153 6 159 165 -6.3 0.1 -6.1 -6.6 12/15/2006 10:50:00 3.2 0.4 4.2 2.3 3.2 0.4 3.8 2.3 3.3 0.4 4.2 2.3 166 9 177 165 -5.8 0.3 -5 -6.4 12/15/2006 11:00:00 3.1 0.5 3.8 1.1 3 0.5 3.8 0.7 3.2 0.5 4.2 1.5 168 7 171 165 -5 0.1 -4.6 -5.3 12/15/2006 11:10:00 2.3 0.6 3.8 0.7 2.4 0.6 3.8 0.7 2.7 0.5 3.8 1.5 160 5 141 165 -4.5 0.1 -4.2 -4.6 12/15/2006 11:20:00 1.4 0.5 2.3 0.4 1.4 0.5 2.3 0.4 2 0.3 3 1.1 165 8 163 165 -3.9 0.3 -3.5 -4.6 12/15/2006 11:30:00 0.7 0.5 2.3 0.4 0.7 0.5 2.3 0.4 1.2 0.7 2.6 0.4 163 1 164 165 -3.5 0.2 -2.8 -4.2 12/15/2006 11:40:00 0.4 0.2 1.1 0.4 0.4 0.1 0.7 0.4 1 0.3 1.9 0.4 146 5 130 165 -3 0.2 -2.6 -3.5 12/15/2006 11:50:00 1 0.6 2.3 0.4 0.8 0.6 2.3 0.4 1.5 0.8 3 0.4 134 11 148 165 -3.5 0.3 -2.4 -3.9 12/15/2006 12:00:00 0.4 0.1 1.1 0.4 0.4 0 0.4 0.4 0.5 0.3 1.5 0.4 122 1 121 165 -3.3 0.1 -3 -3.9 12/15/2006 12:10:00 1.1 0.3 1.9 0.4 0.6 0.3 1.5 0.4 1.2 0.3 1.9 0.4 152 15 150 165 -4 0.3 -3.3 -4.6 12/15/2006 12:20:00 1.8 0.2 2.3 1.5 1.7 0.2 2.3 1.1 1.6 0.2 2.3 1.1 152 7 157 165 -5.2 0.4 -4.2 -5.7 12/15/2006 12:30:00 1.3 0.3 1.9 0.4 1.2 0.3 1.9 0.4 1.2 0.4 1.9 0.4 139 5 145 165 -5.8 0 -5.5 -6.1 12/15/2006 12:40:00 1.2 0.5 2.6 0.4 1.1 0.6 2.6 0.4 1.1 0.6 2.6 0.4 146 12 162 165 -5.9 0.1 -5.5 -6.6 12/15/2006 12:50:00 2.4 0.3 3 1.5 2.3 0.3 3 1.5 2.2 0.3 3 1.5 161 10 168 165 -5.4 0.1 -5 -5.9 12/15/2006 13:00:00 2.2 0.3 3 1.5 2.2 0.3 3 1.5 2.1 0.3 3 1.5 156 5 158 165 -5.2 0.2 -4.6 -5.5 12/15/2006 13:10:00 1.8 0.6 2.6 0.7 2 0.5 2.6 1.1 2.1 0.5 3 1.1 152 2 152 165 -4.5 0.2 -4.2 -5.3 12/15/2006 13:20:00 2.6 0.6 3.8 1.5 2.5 0.6 3.8 1.5 2.7 0.6 3.8 1.5 155 4 159 165 -5.3 0.3 -4.6 -5.7 12/15/2006 13:30:00 2.6 0.3 3.4 1.9 2.5 0.3 3.4 1.5 2.6 0.3 3.4 1.9 144 2 144 165 -5.8 0.1 -5.3 -6.4 12/15/2006 13:40:00 3.1 0.3 3.8 2.3 3 0.3 3.4 2.3 2.9 0.2 3.4 2.3 147 1 147 165 -5.9 0.1 -5.7 -6.6 12/15/2006 13:50:00 3 0.4 3.8 2.3 3 0.4 4.2 2.3 3 0.3 3.8 2.6 148 7 147 165 -6.1 0.1 -5.7 -6.8 12/15/2006 14:00:00 3.6 0.3 4.2 3 3.5 0.3 4.2 3 3.4 0.3 4.2 2.6 149 6 156 165 -6.8 0.2 -6.1 -7.2 12/15/2006 14:10:00 4.3 0.3 4.9 3.4 4.2 0.3 4.9 3.4 4.3 0.4 5.3 3.4 156 6 153 165 -6.9 0.1 -6.6 -7.2 12/15/2006 14:20:00 4.4 0.3 4.9 3.8 4.2 0.3 4.9 3.4 4.2 0.4 4.9 3.4 155 8 159 165 -6.8 0 -6.6 -7 12/15/2006 14:30:00 4.6 0.3 5.3 3.8 4.5 0.3 5.3 3.8 4.6 0.3 4.9 3.8 155 4 153 165 -6.9 0 -6.6 -7 12/15/2006 14:40:00 5.1 0.5 7.2 3.8 5 0.5 6.8 3.8 5 0.5 6.8 4.2 151 4 157 165 -6.7 0.1 -6.4 -7 12/15/2006 14:50:00 6.6 0.9 9.1 4.2 6.5 0.8 8.8 4.2 6.5 1 9.1 3.8 148 9 87 165 -6.2 0 -5.9 -6.6 12/15/2006 15:00:00 6.6 0.7 8.8 4.9 6.4 0.6 8.4 4.2 6.6 0.7 9.1 4.6 155 19 160 165 -6.3 0 -6.1 -6.6 12/15/2006 15:10:00 7.7 1 9.9 5.3 7.5 0.9 9.5 5.3 7.7 0.8 9.5 5.7 155 20 165 165 -6.2 0 -5.9 -6.4 12/15/2006 15:20:00 6.8 1 9.1 4.2 6.6 0.9 8.8 4.2 6.7 0.9 8.8 4.6 162 17 166 165 -6.2 0 -5.9 -6.6 12/15/2006 15:30:00 6.8 0.8 8.8 4.9 6.6 0.8 8.4 4.9 6.8 0.8 8.4 4.9 157 22 161 165 -6.2 0 -5.9 -6.4 12/15/2006 15:40:00 5.9 1 8.8 3.8 5.7 0.9 8.4 3.8 5.8 0.9 8 4.2 164 14 172 165 -6.4 0.1 -5.9 -6.6 12/15/2006 15:50:00 6.1 0.5 6.8 4.6 5.8 0.5 6.8 4.2 6.1 0.5 7.2 4.6 164 10 147 165 -6.2 0 -5.7 -6.6 12/15/2006 16:00:00 5.9 0.7 7.2 4.2 5.7 0.7 7.2 4.2 5.8 0.8 7.6 4.2 160 18 165 165 -6 0.1 -5.7 -6.4 12/15/2006 16:10:00 5.4 0.8 7.6 3.8 5.2 0.7 6.8 3.8 5.4 0.8 7.2 3.8 157 17 165 165 -6 0 -5.5 -6.1 12/15/2006 16:20:00 6 0.7 8 4.6 5.8 0.7 8 4.2 5.9 0.6 7.2 4.6 157 12 157 165 -6 0 -5.7 -6.1 12/15/2006 16:30:00 6 0.4 6.8 4.2 5.8 0.4 6.5 4.2 5.7 0.5 6.5 4.2 158 11 151 165 -6 0.1 -5.7 -6.4 12/15/2006 16:40:00 6.6 0.6 7.6 5.3 6.4 0.5 7.6 4.9 6.5 0.5 7.6 5.3 157 15 165 165 -5.9 0 -5.7 -6.1 12/15/2006 16:50:00 6.5 0.7 7.6 4.2 6.3 0.6 7.6 4.6 6.4 0.6 8 4.9 155 22 159 165 -5.8 0 -5.5 -5.9 12/15/2006 17:00:00 7 0.8 8.4 4.9 6.8 0.8 8 4.6 6.9 0.8 8.4 4.9 154 15 151 165 -5.7 0 -5.5 -5.9 12/15/2006 17:10:00 7 0.6 8.4 5.3 6.8 0.6 8 5.3 7 0.6 8.4 5.3 152 21 129 165 -5.6 0 -5.3 -5.7 12/15/2006 17:20:00 6.6 0.7 8.4 4.6 6.4 0.7 8 4.6 6.7 0.6 8.4 4.9 155 17 154 165 -5.5 0 -5.3 -5.7 12/15/2006 17:30:00 6.4 0.9 8 3.8 6.2 0.9 7.6 3.4 6.5 0.9 8 3.8 155 13 151 165 -5.6 0 -5.5 -5.7 12/15/2006 17:40:00 6.2 0.7 7.6 4.6 6.1 0.7 7.6 4.2 6.4 0.6 8 4.6 153 14 46 165 -5.5 0 -5.3 -5.7 12/15/2006 17:50:00 6.9 0.6 9.1 5.3 6.8 0.6 9.1 5.3 6.9 0.6 8 4.9 152 8 155 165 -5.5 0 -5.3 -5.7 12/15/2006 18:00:00 6.2 0.4 7.2 4.9 6.1 0.4 7.2 4.9 6.2 0.4 7.6 4.9 152 6 153 165 -5.6 0 -5.3 -5.7 12/15/2006 18:10:00 5.7 0.6 7.2 3.8 5.5 0.6 6.8 4.2 5.8 0.6 7.2 3.8 155 13 167 165 -5.4 0 -5.3 -5.7 12/15/2006 18:20:00 6.4 0.7 7.6 4.9 6.1 0.6 7.2 4.6 6.2 0.7 7.6 4.6 173 10 172 165 -5.2 0 -5 -5.5 12/15/2006 18:30:00 5.8 0.6 7.2 4.6 5.5 0.5 6.5 4.2 5.6 0.5 6.5 4.6 166 10 165 165 -5.3 0.1 -4.8 -5.7 12/15/2006 18:40:00 4.8 0.6 6.5 3.4 4.5 0.6 6.5 3.4 4.8 0.5 6.5 3.4 170 10 176 165 -5.6 0.1 -5.3 -5.7 12/15/2006 18:50:00 3.9 0.5 4.9 3 3.7 0.4 4.6 2.6 3.9 0.5 4.9 2.6 181 6 173 165 -6.1 0.1 -5.7 -6.6 12/15/2006 19:00:00 3.5 0.4 4.6 3 3.3 0.3 4.2 2.6 3.3 0.4 4.6 2.6 163 9 169 165 -6.5 0 -6.1 -6.6 12/15/2006 19:10:00 2.7 0.3 3.4 1.9 2.6 0.3 3 1.9 2.7 0.3 3.4 1.9 156 4 154 165 -6.4 0.1 -6.1 -6.6 12/15/2006 19:20:00 3.4 0.6 4.6 2.3 3.3 0.6 4.6 2.3 2.9 0.5 4.2 1.9 156 4 152 165 -5.9 0.1 -5.5 -6.4 12/15/2006 19:30:00 4.3 0.5 5.3 2.6 4.3 0.5 5.7 2.6 4 0.6 5.7 2.6 140 9 128 165 -5.2 0.2 -4.6 -5.7 12/15/2006 19:40:00 4.4 0.4 5.3 2.6 4.4 0.4 5.3 2.6 4.1 0.4 5.3 3 135 5 135 165 -4.7 0.1 -4.4 -5 12/15/2006 19:50:00 5 0.8 6.8 3 5 0.8 6.8 3.4 4.7 0.6 6.5 3.4 141 9 143 165 -4.1 0.1 -3.7 -4.4 12/15/2006 20:00:00 5 0.8 7.2 3.4 5 0.7 6.8 3.4 4.8 0.6 6.5 3.4 136 6 143 165 -3.8 0.1 -3.5 -4.2 12/15/2006 20:10:00 5.6 0.9 8 3.8 5.6 0.9 8 3.8 5.4 0.7 7.6 4.2 138 7 129 165 -3.5 0.1 -3.3 -3.9 12/15/2006 20:20:00 5.3 0.8 7.6 3.4 5.2 0.8 7.2 3.4 5 0.7 6.5 3.4 138 7 143 165 -3.5 0 -3.3 -3.5 12/15/2006 20:30:00 4.9 0.8 6.8 3 4.9 0.7 6.8 3 4.7 0.7 6.5 3 135 7 142 165 -3.2 0.1 -2.8 -3.5 12/15/2006 20:40:00 4.8 0.9 6.8 2.6 4.8 0.8 6.8 2.6 4.4 0.8 6.1 2.6 133 8 144 165 -3 0 -2.8 -3 12/15/2006 20:50:00 5.2 0.7 7.6 3.4 5.2 0.7 7.6 3.8 5 0.7 7.2 3.4 128 6 128 165 -2.8 0 -2.6 -2.8 12/15/2006 21:00:00 6.1 0.5 7.2 4.9 6.2 0.5 7.6 4.6 5.8 0.5 7.2 4.2 124 4 128 165 -2.5 0.1 -2.1 -2.8 12/15/2006 21:10:00 6.6 1 8.8 4.2 6.6 1 8.8 4.2 6.5 0.9 8.4 4.6 128 9 143 165 -2.1 0 -1.9 -2.1 12/15/2006 21:20:00 7.2 0.8 9.5 4.9 7.2 0.8 9.5 4.9 6.9 0.7 8.8 4.9 130 6 130 165 -2 0.1 -1.7 -2.4 12/15/2006 21:30:00 7.1 0.9 9.1 4.6 7.1 0.9 9.1 4.2 6.8 0.8 9.1 4.6 129 8 128 165 -1.7 0.1 -1.4 -1.9 12/15/2006 21:40:00 8.3 0.7 9.9 6.1 8.4 0.8 10.3 6.1 8.2 0.7 9.9 6.5 125 5 126 165 -1.2 0.1 -0.8 -1.4 12/15/2006 21:50:00 9.8 0.5 11.1 8.4 9.9 0.5 11.5 8.4 9.7 0.5 11.1 8 124 3 121 165 -0.8 0.1 -0.5 -1.4 12/15/2006 22:00:00 10.6 0.9 13 8 10.6 0.9 13 8 10.5 0.8 13 8.4 127 5 122 165 -0.5 0 -0.3 -1.2 12/15/2006 22:10:00 9.7 1.4 13.3 6.1 9.8 1.4 13.3 5.7 9.5 1.5 13.3 6.5 126 8 122 165 -0.3 0.1 -0.3 -1 12/15/2006 22:20:00 10 1.1 13 6.8 10 1.1 13 6.8 9.9 1.2 13.3 6.5 126 6 131 165 -0.2 0 0.2 -0.8 12/15/2006 22:30:00 10.3 1 13.3 6.8 10.4 1 13.3 7.2 10.2 1.1 13.3 7.6 128 6 134 165 0.1 0 0.2 -0.3 12/15/2006 22:40:00 11.2 1.2 14.5 8.4 11.3 1.2 14.5 8.8 11.1 1.1 14.5 8 130 6 129 165 0.2 0 0.2 -0.3 12/15/2006 22:50:00 11.9 1.3 15.3 8.4 11.9 1.2 15.6 8.8 11.9 1.3 15.3 8.4 131 7 137 165 0.2 0.1 0.7 -0.3 12/15/2006 23:00:00 11.8 1.5 16.4 8.4 11.9 1.5 17.2 8.4 11.7 1.6 15.6 7.6 129 7 122 165 0.3 0.1 0.7 -0.3 12/15/2006 23:10:00 11.4 1.3 14.5 8.4 11.5 1.3 14.9 8.4 11.3 1.3 14.5 8 127 7 136 165 0.3 0.1 0.7 -0.1 12/15/2006 23:20:00 11.4 1.4 14.9 8.4 11.5 1.4 14.9 8 11.3 1.4 14.9 8.4 128 6 135 165 0.4 0 0.7 -0.1 12/15/2006 23:30:00 12 1.3 14.9 8.8 12.1 1.3 14.9 8.8 12 1.4 15.3 7.2 127 6 126 165 0.4 0 0.7 0.2 12/15/2006 23:40:00 11.6 1 13.7 9.1 11.6 1 14.5 9.1 11.5 1.1 13.7 8.4 125 7 124 165 0.5 0 0.7 0.4 12/15/2006 23:50:00 11.2 1.2 14.1 8 11.3 1.2 14.5 8 11.2 1.2 14.1 8 127 8 112 165 0.5 0 0.7 0.2 12/16/2006 00:00:00 11 1 13.7 8 11.2 1.1 14.1 8.4 10.9 1.2 14.5 7.6 136 0 136 165 0.5 0 0.9 0.4 12/16/2006 00:10:00 11.7 1.3 14.9 8.8 11.8 1.3 15.3 8.8 11.5 1.4 14.5 8.4 136 0 136 165 0.6 0 0.9 0.4 12/16/2006 00:20:00 11.3 1 13.3 8.4 11.5 1 13.3 8 11.3 1.2 13.7 7.2 136 0 136 165 0.7 0 0.9 0.7 12/16/2006 00:30:00 11.1 1 14.1 8.8 11.3 1.1 14.5 8.4 11.1 1.1 14.1 8.4 136 0 136 165 0.7 0 0.9 0.7 12/16/2006 00:40:00 11.1 1.3 14.5 8 11.3 1.3 14.5 8 11.2 1.4 15.3 8 136 0 136 165 0.8 0 0.9 0.7 12/16/2006 00:50:00 10.1 1.1 13 6.5 10.3 1.1 13.3 6.8 10 1.2 13 6.5 136 0 136 165 0.8 0 1.1 0.7 12/16/2006 01:00:00 10 1.2 13 6.8 10.2 1.3 13 6.5 10 1.3 13 6.5 136 0 136 165 0.8 0 0.9 0.7 12/16/2006 01:10:00 10.1 0.8 12.6 7.2 10.3 0.9 12.6 6.8 10.1 1 13.3 7.2 136 0 136 165 0.8 0 1.1 0.7 12/16/2006 01:20:00 10.1 0.9 12.6 7.2 10.4 0.9 13 7.2 10.1 1.1 13 5.7 136 0 135 165 0.8 0 1.1 0.9 12/16/2006 01:30:00 9.5 1 11.8 6.5 9.8 1 12.2 6.8 9.5 1.3 12.2 6.1 135 0 135 165 0.8 0 1.1 0.9 12/16/2006 01:40:00 9.8 1 12.6 6.5 10.1 1 12.6 6.1 9.8 1.1 12.6 6.5 135 0 135 165 0.9 0 1.1 0.9 12/16/2006 01:50:00 9.5 1 11.8 6.5 9.9 1 12.2 6.5 9.7 1.1 12.2 6.5 135 0 135 165 0.9 0 1.1 0.4 12/16/2006 02:00:00 9.9 1 12.2 6.5 10.2 1 12.6 6.5 9.9 1.1 12.6 6.8 135 0 135 165 0.9 0 1.1 0.4 12/16/2006 02:10:00 9.5 0.8 12.2 7.2 9.9 0.8 12.2 7.6 9.6 1 12.2 6.8 135 0 135 165 0.9 0 1.1 0.4 12/16/2006 02:20:00 9.7 1 11.8 6.8 10 1 12.2 7.2 9.5 1.2 12.2 6.5 135 0 135 165 1 0 1.1 0.7 12/16/2006 02:30:00 9.4 0.8 11.5 7.2 9.8 0.9 12.2 7.2 9.4 1 11.8 6.8 135 0 135 165 1 0 1.4 0.7 12/16/2006 02:40:00 9.2 1.1 12.2 6.5 9.5 1.1 12.6 6.8 9.2 1.3 12.6 5.7 135 0 135 165 1 0 1.1 0.7 12/16/2006 02:50:00 9.1 0.8 11.1 6.5 9.6 0.8 11.8 6.8 9.2 1 11.5 6.1 135 0 135 165 1 0 1.4 0.7 12/16/2006 03:00:00 8.8 1 11.8 5.3 9.2 1.1 11.8 5.7 8.7 1.1 11.1 6.1 135 0 135 165 1.1 0 1.4 0.7 12/16/2006 03:10:00 9.2 1.1 11.5 5.7 9.6 1.1 11.5 5.7 9.1 1.2 11.8 6.5 135 0 135 165 1.1 0 1.4 0.7 12/16/2006 03:20:00 9.3 1.1 11.5 6.5 9.6 1.1 11.8 6.5 9.1 1.3 11.5 6.1 135 0 135 165 1.1 0 1.4 0.7 12/16/2006 03:30:00 8.3 1.2 10.7 5.7 8.6 1.2 10.7 5.7 8.3 1.1 11.1 5.3 135 0 135 165 1.1 0 1.4 0.7 12/16/2006 03:40:00 8.4 1 10.7 5.7 8.7 1 10.7 5.7 8.5 1.1 11.1 5.7 135 0 135 165 1.2 0 1.4 0.7 12/16/2006 03:50:00 8.3 1 10.7 4.9 8.5 1 10.7 5.7 8.4 1 11.1 5.3 135 0 135 165 1.2 0 1.4 0.7 12/16/2006 04:00:00 8.2 1 9.9 5.3 8.3 0.9 10.3 5.7 8.4 1 10.3 6.1 135 0 135 165 1.2 0 1.6 1.1 12/16/2006 04:10:00 8.8 0.7 10.3 6.1 8.6 0.8 9.9 6.1 8.9 1 10.7 6.1 135 0 135 165 1.2 0 1.4 1.1 12/16/2006 04:20:00 7.7 0.8 9.5 5.7 7.7 0.7 9.5 5.7 8 0.9 10.3 5.7 135 0 135 165 1.3 0 1.6 1.1 12/16/2006 04:30:00 8.3 0.7 9.5 6.1 8.2 0.7 9.5 6.1 8.4 0.8 9.9 6.1 135 0 135 165 1.4 0 1.6 1.4 12/16/2006 04:40:00 7.2 1 9.5 4.6 7.2 1 9.5 4.9 7.2 1.2 9.9 4.2 135 0 135 165 1.4 0 1.6 1.4 12/16/2006 04:50:00 6.9 0.8 8.8 4.6 7 0.8 9.1 4.9 7.2 0.8 9.5 4.9 135 0 135 165 1.4 0 1.6 1.4 12/16/2006 05:00:00 6.5 1.2 8.8 3.8 6.4 1.1 8.8 3.8 6.6 1.2 9.1 3.8 135 0 135 165 1.4 0 1.6 1.4 12/16/2006 05:10:00 6.8 0.8 8.8 4.9 6.6 0.7 8.8 4.9 6.8 0.9 9.1 5.3 135 0 135 165 1.4 0 1.6 1.4 12/16/2006 05:20:00 6.4 1 8.4 4.2 6.1 0.9 8 4.2 6.7 0.9 8.4 4.9 135 0 135 165 1.4 0 1.6 1.4 12/16/2006 05:30:00 6.2 1 8.4 4.2 5.8 0.8 8 3.8 6.4 1 8.8 3.8 135 0 135 165 1.3 0 1.6 1.4 12/16/2006 05:40:00 5.8 1 8 3.8 5.5 1 7.6 3.4 6 1 8 3.8 135 0 135 165 1.3 0 1.6 1.1 12/16/2006 05:50:00 5.1 0.8 7.2 3 4.8 0.7 6.8 2.6 5.1 0.8 6.8 3.4 135 0 135 165 1.2 0 1.6 1.1 12/16/2006 06:00:00 4.8 1.1 7.2 2.3 4.5 1 6.8 1.9 5.1 1 7.6 3 135 0 135 165 1.2 0 1.4 1.1 12/16/2006 06:10:00 3.2 1.7 6.8 0.4 3.3 1.1 6.8 1.1 3.9 1.2 8.4 1.5 135 0 135 165 1.2 0 1.4 0.9 12/16/2006 06:20:00 0.4 0 0.4 0.4 3.3 1.1 6.1 0.4 3.8 1 6.5 1.5 135 0 165 165 1.1 0 1.4 0.7 12/16/2006 06:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 3.7 1 7.2 1.5 135 0 165 165 0.9 0 1.4 0.4 12/16/2006 06:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 3.6 0.8 5.7 1.9 135 0 165 165 0.9 0.1 1.1 0.4 12/16/2006 06:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 3.5 0.6 4.9 2.3 135 0 165 165 0.8 0 1.1 0.4 12/16/2006 07:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 3.6 0.6 4.9 2.3 135 0 165 165 0.8 0 1.1 0.7 12/16/2006 07:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 4.4 0.6 6.8 2.6 135 0 165 165 0.8 0 1.1 0.4 12/16/2006 07:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 4.3 0.6 5.3 2.6 135 0 165 165 0.8 0 1.1 0.4 12/16/2006 07:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 4.8 0.6 6.1 3.4 135 0 165 165 0.9 0 1.1 0.4 12/16/2006 07:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 5.1 0.6 6.1 3.4 135 0 165 165 0.9 0 1.1 0.4 12/16/2006 07:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 5.2 0.5 6.5 3.8 135 0 165 165 0.9 0 1.1 0.4 12/16/2006 08:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 5.6 0.7 7.2 3.4 135 0 165 165 0.9 0 1.1 0.4 12/16/2006 08:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 6 0.6 7.6 4.6 135 0 165 165 1 0 1.1 0.7 12/16/2006 08:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 6 0.8 7.6 3.8 135 0 165 165 1 0 1.4 0.7 12/16/2006 08:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 5.9 0.6 7.6 4.6 135 0 165 165 1.1 0 1.4 0.7 12/16/2006 08:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 6.1 0.6 7.6 4.6 135 0 165 165 1.1 0 1.4 0.9 12/16/2006 08:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 5.6 0.7 6.8 3.8 135 0 165 165 1.1 0 1.4 0.9 12/16/2006 09:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 5.3 0.6 6.8 3.4 135 0 165 165 1.1 0 1.4 0.9 12/16/2006 09:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 5.1 0.5 6.5 3.4 135 0 165 165 1.1 0 1.4 0.9 12/16/2006 09:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 4.8 0.6 6.5 3.4 135 0 165 165 1 0 1.4 0.9 12/16/2006 09:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 5.1 0.6 6.8 3.4 135 0 165 165 1 0 1.1 0.9 12/16/2006 09:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 5 0.7 7.6 3.4 135 0 165 165 1 0 1.4 0.9 12/16/2006 09:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 5.7 0.6 7.2 4.2 135 0 165 165 1 0 1.1 0.9 12/16/2006 10:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 4.2 0.5 6.1 3 135 0 165 165 1.1 0 1.4 0.9 12/16/2006 10:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 3.6 0.7 6.5 2.6 135 0 165 165 1.1 0 1.4 0.9 12/16/2006 10:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 3.3 0.7 5.7 1.9 135 0 165 165 1.1 0 1.4 0.9 12/16/2006 10:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 3.5 0.6 5.7 2.6 135 0 165 165 0.9 0 1.1 0.9 12/16/2006 10:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 4 0.8 6.5 2.3 135 0 165 165 0.8 0 1.1 0.9 12/16/2006 10:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 4.9 1 8 3 135 0 165 165 0.8 0.1 0.9 0.2 12/16/2006 11:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 5.1 1 8.4 2.3 135 0 165 165 0.8 0.1 0.9 0.2 12/16/2006 11:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 4.2 0.7 6.1 2.6 135 0 165 165 0.8 0.1 0.9 0.2 12/16/2006 11:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 5.8 1.3 9.5 3.4 135 0 165 165 0.8 0.1 0.9 0.2 12/16/2006 11:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 6 1.3 9.9 3 135 0 165 165 0.8 0.1 0.9 0.2 12/16/2006 11:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 7.1 1.5 10.3 3.8 135 0 165 165 0.7 0.1 0.9 0.2 12/16/2006 11:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 8.1 1.1 11.5 5.3 135 0 165 165 0.8 0.1 0.9 0.2 12/16/2006 12:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 8.8 1.3 12.2 6.1 135 0 165 165 0.8 0.1 0.9 0.4 12/16/2006 12:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 6.9 1.7 11.8 3.8 135 0 165 165 0.8 0.1 0.9 0.4 12/16/2006 12:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 8.5 1.3 11.8 4.9 135 0 165 165 0.8 0.1 1.1 0.4 12/16/2006 12:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 8.3 1.1 11.5 5.7 135 0 165 165 0.9 0 1.1 0.7 12/16/2006 12:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 9.5 1.2 13 6.1 135 0 165 165 0.9 0 1.1 0.4 12/16/2006 12:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 9.4 1.1 11.8 6.5 135 0 165 165 0.9 0 1.4 0.4 12/16/2006 13:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 9.2 1 12.2 6.5 135 0 165 165 0.9 0 1.1 0.7 12/16/2006 13:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 9.9 0.9 12.2 7.2 135 0 165 165 1 0 1.4 0.7 12/16/2006 13:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 9.5 1 12.2 6.5 135 0 165 165 1 0 1.1 0.9 12/16/2006 13:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 9.1 1.1 11.8 6.1 135 0 165 165 1.1 0 1.4 0.9 12/16/2006 13:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 8.9 1.3 12.2 6.1 135 0 165 165 1 0 1.4 0.9 12/16/2006 13:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 9.2 1 11.8 6.8 135 0 165 165 0.9 0 1.1 0.7 12/16/2006 14:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 9.8 1.5 14.9 7.2 135 0 165 165 0.8 0 0.9 0.7 12/16/2006 14:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 11.1 1.2 14.1 8 135 0 165 165 0.6 0 0.9 0.4 12/16/2006 14:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 9.8 1 12.2 6.5 135 0 165 165 0.5 0 0.7 0.4 12/16/2006 14:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 11.3 1.1 14.5 8.8 134 0 165 165 0.4 0 0.7 0.2 12/16/2006 14:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 10.5 1.1 14.5 6.8 134 0 165 165 0.2 0 0.7 0.2 12/16/2006 14:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 10.7 1.2 14.5 7.6 177 112 165 165 0 0 0.2 -0.1 12/16/2006 15:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 10.6 1.4 15.6 7.6 340 12 165 165 -0.1 0 -0.1 -0.3 12/16/2006 15:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 10.5 1.2 15.3 7.2 339 13 165 165 -0.2 0 -0.1 -0.3 12/16/2006 15:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 11.7 1.5 16.1 8 345 12 165 165 -0.3 0 -0.1 -0.5 12/16/2006 15:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 9.6 1.1 13 6.5 325 14 165 165 -0.4 0 -0.3 -0.5 12/16/2006 15:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 10.1 1.7 14.9 6.5 317 9 165 165 -0.5 0 -0.3 -0.8 12/16/2006 15:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 10.2 1.2 14.1 7.2 320 11 165 165 -0.6 0 -0.5 -0.8 12/16/2006 16:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 11 1.5 15.3 7.2 312 8 165 165 -0.8 0 -0.5 -0.8 12/16/2006 16:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 11.1 1.1 14.1 8.8 312 8 165 165 -0.8 0 -0.5 -0.8 12/16/2006 16:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 11.6 1.2 15.6 8.8 311 6 165 165 -0.9 0 -0.8 -1.2 12/16/2006 16:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 12.5 1.2 15.3 9.1 313 6 165 165 -0.9 0 -0.8 -1.2 12/16/2006 16:40:00 0.4 0 0.4 0.4 2.7 4.5 13.7 0.4 12.6 1.1 15.6 9.9 315 7 165 165 -0.9 0 -0.8 -1.2 12/16/2006 16:50:00 0.4 0 0.4 0.4 10.9 1.3 15.6 8 11.8 1.4 16.1 8 312 7 165 165 -0.9 0 -0.5 -1 12/16/2006 17:00:00 0.4 0 0.4 0.4 11 1.3 15.6 8.4 11.8 1.3 15.3 8 313 9 165 165 -0.9 0 -0.8 -1.2 12/16/2006 17:10:00 0.4 0 0.4 0.4 11.5 1.2 16.4 8.4 12.8 1.3 16.4 9.5 317 8 165 165 -0.9 0 -0.8 -1.2 12/16/2006 17:20:00 0.4 0 0.4 0.4 11.6 1 14.5 8.4 13 1.1 16.1 9.5 317 6 165 165 -1 0 -0.8 -1.2 12/16/2006 17:30:00 0.4 0 0.4 0.4 11.1 1.3 15.6 7.6 11.9 1.3 14.5 7.6 314 6 165 165 -1 0 -0.8 -1.2 12/16/2006 17:40:00 0.4 0 0.4 0.4 10.7 1.4 14.5 8 10.9 1.5 16.1 8 311 7 165 165 -1 0 -0.8 -1.2 12/16/2006 17:50:00 0.4 0 0.4 0.4 11.4 0.6 13 9.9 11.5 0.9 13.7 8 310 6 165 165 -1 0 -0.8 -1.2 12/16/2006 18:00:00 0.4 0 0.4 0.4 11.2 1 13.3 8.4 11.8 0.8 14.1 9.1 312 5 165 165 -1 0 -0.8 -1.2 12/16/2006 18:10:00 0.4 0 0.4 0.4 10.8 1.2 13 8 11.2 1.2 13.7 7.6 311 6 165 165 -0.9 0 -0.8 -1.2 12/16/2006 18:20:00 0.4 0 0.4 0.4 10.2 1.3 14.5 7.2 10.2 1.2 14.5 7.6 309 7 165 165 -0.9 0 -0.8 -1.2 12/16/2006 18:30:00 0.4 0 0.4 0.4 10.1 1.2 13.3 7.6 9.2 1.1 12.2 6.5 305 7 165 165 -0.9 0 -0.8 -1.2 12/16/2006 18:40:00 0.4 0 0.4 0.4 9.9 1.4 13 7.6 9.2 1.1 12.6 6.1 306 6 165 165 -0.9 0 -0.8 -1 12/16/2006 18:50:00 0.4 0 0.4 0.4 9.2 1.2 13.3 7.2 8.7 1.2 12.2 5.7 305 9 165 165 -0.9 0 -0.8 -1 12/16/2006 19:00:00 0.4 0 0.4 0.4 10.3 1.4 13.3 7.2 9 1.2 12.6 6.1 302 7 165 165 -0.9 0 -0.8 -1 12/16/2006 19:10:00 0.4 0 0.4 0.4 10.3 1.4 12.6 7.6 8.4 1 11.5 5.3 300 6 165 165 -0.9 0 -0.8 -1 12/16/2006 19:20:00 0.4 0 0.4 0.4 8.3 0.4 8.8 6.8 7.6 1.4 11.8 4.9 302 8 165 165 -0.9 0 -0.8 -1 12/16/2006 19:30:00 0.4 0 0.4 0.4 8.3 0.3 8.8 7.6 8.6 1.2 11.1 5.7 307 6 165 165 -0.9 0 -0.8 -1 12/16/2006 19:40:00 0.4 0 0.4 0.4 8.2 0.3 8.8 7.2 7.2 0.9 9.9 5.7 303 6 165 165 -0.9 0 -0.5 -1 12/16/2006 19:50:00 0.4 0 0.4 0.4 8.2 0.4 8.8 7.2 9.2 1.5 12.2 5.7 310 7 165 165 -0.9 0 -0.5 -1 12/16/2006 20:00:00 0.4 0 0.4 0.4 8.5 0.3 9.1 7.2 10.3 0.9 12.6 8.4 312 5 165 165 -0.9 0 -0.8 -1 12/16/2006 20:10:00 0.4 0 0.4 0.4 8.6 0.3 9.9 8 10.5 0.8 12.2 8 311 4 165 165 -0.9 0 -0.8 -1.2 12/16/2006 20:20:00 0.4 0 0.4 0.4 8.3 0.3 8.8 7.2 8.3 1 10.7 5.7 307 6 165 165 -0.9 0 -0.8 -1.2 12/16/2006 20:30:00 0.4 0 0.4 0.4 8.5 0.2 9.1 7.6 8.8 1 11.5 6.5 307 5 165 165 -1 0 -0.8 -1.2 12/16/2006 20:40:00 0.4 0 0.4 0.4 8.3 0.4 8.8 6.8 8.1 1.1 10.7 5.7 306 8 165 165 -1 0 -0.8 -1.2 12/16/2006 20:50:00 0.4 0 0.4 0.4 8.2 0.3 9.1 7.2 7.7 1.3 11.5 5.3 302 7 165 165 -1 0 -0.8 -1.2 12/16/2006 21:00:00 0.4 0 0.4 0.4 8.5 0.2 9.1 7.6 8.3 1.4 11.8 5.7 295 5 165 165 -1 0 -0.8 -1.2 12/16/2006 21:10:00 0.4 0 0.4 0.4 8.5 0.4 10.7 7.2 7.7 1 10.3 5.7 300 7 165 165 -1.1 0 -0.8 -1.2 12/16/2006 21:20:00 0.4 0 0.4 0.4 8.4 0.3 8.8 7.2 7.7 1.2 11.1 4.9 299 6 165 165 -1.1 0 -0.8 -1.2 12/16/2006 21:30:00 0.4 0 0.4 0.4 8.4 0.3 8.8 7.6 7.5 1 10.3 5.3 301 6 165 165 -1.1 0 -0.8 -1.2 12/16/2006 21:40:00 0.4 0 0.4 0.4 8.4 0.3 8.8 6.8 7.4 1 11.1 4.9 299 5 165 165 -1.1 0 -1 -1.2 12/16/2006 21:50:00 0.4 0 0.4 0.4 8.3 0.3 8.8 7.2 7.3 0.9 9.9 5.3 300 5 165 165 -1.2 0 -0.8 -1.2 12/16/2006 22:00:00 0.4 0 0.4 0.4 8.3 0.3 8.8 7.2 7.2 0.8 9.5 5.3 302 5 165 165 -1.2 0 -1 -1.2 12/16/2006 22:10:00 0.4 0 0.4 0.4 8.3 0.3 8.8 7.2 6.7 0.7 8.8 4.9 300 5 165 165 -1.2 0 -0.8 -1.4 12/16/2006 22:20:00 0.4 0 0.4 0.4 8.2 0.4 8.8 6.8 6.6 0.7 9.1 5.3 302 4 165 165 -1.2 0 -1 -1.4 12/16/2006 22:30:00 0.4 0 0.4 0.4 8.3 0.3 8.8 7.2 6.8 0.9 9.5 4.9 302 5 165 165 -1.2 0 -1 -1.4 12/16/2006 22:40:00 0.4 0 0.4 0.4 7.7 0.5 8.8 6.5 7.9 0.9 9.9 5.3 310 6 165 165 -1.2 0 -1.2 -1.4 12/16/2006 22:50:00 0.4 0 0.4 0.4 7.7 0.5 8.8 6.5 8 0.7 9.9 6.1 309 6 165 165 -1.3 0 -1.2 -1.4 12/16/2006 23:00:00 0.4 0 0.4 0.4 8 0.5 8.8 6.5 8.8 0.8 10.3 6.8 311 4 165 165 -1.3 0 -1.2 -1.4 12/16/2006 23:10:00 0.4 0 0.4 0.4 7.6 0.5 8.4 6.5 8.4 0.7 9.9 6.8 312 5 165 165 -1.3 0 -1 -1.4 12/16/2006 23:20:00 0.4 0 0.4 0.4 7.6 0.5 8.8 6.5 8.1 0.8 9.9 5.3 312 5 165 165 -1.4 0 -1.2 -1.4 12/16/2006 23:30:00 0.4 0 0.4 0.4 7.4 0.5 8.8 6.1 7.1 1 10.3 4.6 307 5 165 165 -1.4 0 -1.2 -1.7 12/16/2006 23:40:00 0.4 0 0.4 0.4 8.3 0.4 8.8 6.1 8.5 1.2 10.3 4.9 308 4 165 165 -1.5 0 -1.4 -1.7 12/16/2006 23:50:00 0.4 0 0.4 0.4 8.1 0.3 8.8 7.2 8.5 0.7 9.9 6.5 309 3 165 165 -1.6 0 -1.4 -1.7 12/17/2006 00:00:00 0.4 0 0.4 0.4 7.8 0.4 8.4 6.8 8.1 0.7 9.9 5.7 310 4 165 165 -1.6 0 -1.2 -1.9 12/17/2006 00:10:00 0.4 0 0.4 0.4 7.4 0.5 8 5.7 8.1 0.6 9.9 6.5 314 4 165 165 -1.6 0 -1.4 -1.9 12/17/2006 00:20:00 0.4 0 0.4 0.4 6.8 0.5 7.6 5.7 7.4 0.8 9.1 4.6 315 4 165 165 -1.7 0 -1.4 -1.9 12/17/2006 00:30:00 0.4 0 0.4 0.4 7.2 0.5 8.8 5.7 7.6 0.8 9.1 4.6 312 4 165 165 -1.7 0 -1.4 -1.9 12/17/2006 00:40:00 0.4 0 0.4 0.4 7.3 0.4 8 6.1 7.2 0.7 8.4 4.9 309 4 165 165 -1.7 0 -1.4 -1.9 12/17/2006 00:50:00 0.4 0 0.4 0.4 6.6 0.8 8.4 4.6 6.3 0.9 8.4 4.2 309 5 165 165 -1.7 0 -1.7 -1.9 12/17/2006 01:00:00 0.4 0 0.4 0.4 5.1 0.6 6.5 3.4 4.7 0.9 7.6 2.6 308 11 165 165 -1.8 0 -1.7 -1.9 12/17/2006 01:10:00 0.4 0 0.4 0.4 5.5 0.5 6.8 4.2 5.1 0.8 7.2 3 310 9 165 165 -1.9 0 -1.7 -2.1 12/17/2006 01:20:00 0.4 0 0.4 0.4 5.9 0.6 8.4 4.6 5.6 0.9 9.5 3.8 312 9 165 165 -1.8 0 -1.7 -1.9 12/17/2006 01:30:00 0.4 0 0.4 0.4 4.9 1 7.6 2.6 4.1 0.9 7.2 2.3 307 12 165 165 -1.8 0 -1.4 -1.9 12/17/2006 01:40:00 0.4 0 0.4 0.4 3.2 0.8 5.7 1.5 3.4 1 6.5 1.5 327 15 165 165 -1.9 0.1 -1.4 -2.1 12/17/2006 01:50:00 0.4 0 0.4 0.4 4 1.1 5.7 0.4 4.6 1 6.8 1.5 340 13 165 165 -2 0 -1.9 -2.1 12/17/2006 02:00:00 0.4 0 0.4 0.4 4.4 1.1 7.2 2.3 4.8 1.2 7.2 2.3 334 9 165 165 -1.9 0 -1.7 -2.1 12/17/2006 02:10:00 0.4 0 0.4 0.4 3.8 1.2 6.1 1.5 4.3 1.7 7.6 1.1 328 16 165 165 -1.8 0 -1.7 -2.1 12/17/2006 02:20:00 0.4 0 0.4 0.4 2.4 1 4.2 0.4 2.5 1 4.6 0.7 322 14 165 165 -1.9 0.1 -1.4 -2.1 12/17/2006 02:30:00 0.4 0 0.4 0.4 1.3 0.8 3 0.4 1.5 0.8 3.4 0.4 308 21 165 165 -2 0 -1.7 -2.1 12/17/2006 02:40:00 0.4 0 0.4 0.4 0.8 0.6 2.6 0.4 1.2 0.7 3 0.4 324 24 165 165 -2 0 -1.7 -2.1 12/17/2006 02:50:00 0.4 0 0.4 0.4 1.2 0.6 2.6 0.4 1.4 0.7 3 0.4 316 23 165 165 -1.9 0 -1.7 -2.1 12/17/2006 03:00:00 0.4 0 0.4 0.4 2.8 0.9 5.7 0.7 3.6 1.1 6.5 1.9 338 21 165 165 -1.9 0 -1.7 -2.1 12/17/2006 03:10:00 0.4 0 0.4 0.4 3.6 1.2 6.8 1.1 4.4 1.2 7.6 1.9 341 16 165 165 -1.9 0 -1.7 -2.1 12/17/2006 03:20:00 0.4 0 0.4 0.4 1.5 1 4.2 0.4 2.8 0.9 5.3 1.5 351 13 165 165 -1.9 0 -1.7 -2.1 12/17/2006 03:30:00 0.4 0 0.4 0.4 3.6 1.5 6.1 0.7 4.2 1.4 6.8 1.5 339 9 165 165 -1.9 0 -1.4 -1.9 12/17/2006 03:40:00 0.4 0 0.4 0.4 3.9 1.3 6.8 0.7 4.7 1.2 7.2 1.9 345 10 165 165 -1.9 0 -1.7 -2.1 12/17/2006 03:50:00 0.4 0 0.4 0.4 4.8 1 6.8 2.6 5.2 1 7.6 3.4 340 10 165 165 -2 0 -1.4 -2.1 12/17/2006 04:00:00 0.4 0 0.4 0.4 4.3 1.6 7.6 1.5 4.4 1.5 7.2 1.5 337 11 165 165 -1.9 0 -1.4 -2.1 12/17/2006 04:10:00 0.4 0 0.4 0.4 2.2 0.7 3.4 0.4 2.8 0.5 4.2 1.5 343 12 165 165 -2 0 -1.7 -2.1 12/17/2006 04:20:00 0.4 0 0.4 0.4 4.7 1 6.5 2.3 5.1 1 7.6 2.6 333 13 165 165 -1.8 0 -1.4 -2.1 12/17/2006 04:30:00 0.4 0 0.4 0.4 5.1 0.8 7.2 3 5.6 1 8 3.4 340 9 165 165 -1.7 0 -1.4 -1.9 12/17/2006 04:40:00 0.4 0 0.4 0.4 2.7 1.2 5.7 0.4 3 1.5 6.8 0.7 322 23 165 165 -1.7 0 -1.4 -1.9 12/17/2006 04:50:00 0.4 0 0.4 0.4 0.5 0.4 2.3 0.4 1.3 0.6 3.4 0.4 5 16 165 165 -1.7 0 -1.4 -1.9 12/17/2006 05:00:00 0.4 0 0.4 0.4 1.8 1.2 4.2 0.4 2.6 1 4.9 0.7 338 19 165 165 -1.7 0 -1.4 -1.9 12/17/2006 05:10:00 0.4 0 0.4 0.4 3.1 1.2 5.7 0.4 3.6 1.1 6.1 1.5 340 12 165 165 -1.7 0 -1.4 -1.9 12/17/2006 05:20:00 0.4 0 0.4 0.4 2.2 1.2 4.6 0.4 3.3 0.6 4.9 2.3 353 13 165 165 -1.7 0 -1.4 -1.9 12/17/2006 05:30:00 0.4 0 0.4 0.4 1.1 0.7 3.4 0.4 2.3 0.6 4.2 1.1 359 16 165 165 -1.7 0 -1.4 -1.9 12/17/2006 05:40:00 0.4 0 0.4 0.4 0.6 0.6 2.6 0.4 2.2 0.5 3.8 1.1 2 10 165 165 -1.7 0 -1.4 -1.9 12/17/2006 05:50:00 0.4 0 0.4 0.4 0.9 0.6 2.6 0.4 2.3 0.7 3.8 0.7 1 15 165 165 -1.7 0 -1.4 -1.9 12/17/2006 06:00:00 0.4 0 0.4 0.4 1.4 0.5 3.4 0.4 3.2 0.7 5.3 1.9 355 8 165 165 -1.7 0 -1.4 -1.9 12/17/2006 06:10:00 0.4 0 0.4 0.4 2.6 0.6 4.2 1.1 3.4 0.5 4.9 2.3 337 12 165 165 -1.7 0 -1.4 -1.9 12/17/2006 06:20:00 0.4 0 0.4 0.4 2.4 1 4.6 0.4 3.8 0.6 5.7 2.6 351 10 165 165 -1.8 0 -1.4 -1.9 12/17/2006 06:30:00 0.4 0 0.4 0.4 1.8 0.9 4.2 0.4 4.2 0.8 6.8 2.6 2 8 165 165 -1.7 0 -1.4 -1.9 12/17/2006 06:40:00 0.4 0 0.4 0.4 2.3 0.8 4.9 0.7 4.9 0.7 7.2 3.4 360 8 165 165 -1.6 0 -1.4 -1.9 12/17/2006 06:50:00 0.4 0 0.4 0.4 2 0.8 4.6 0.7 4.6 0.8 6.1 3 358 8 165 165 -1.6 0 -1.2 -1.7 12/17/2006 07:00:00 0.4 0 0.4 0.4 3 0.8 4.9 1.1 4.6 1 7.2 2.6 351 12 165 165 -1.7 0 -1.4 -1.9 12/17/2006 07:10:00 0.4 0 0.4 0.4 2.2 0.9 4.6 0.4 3.2 0.6 4.6 2.3 347 9 165 165 -1.7 0 -1.4 -1.9 12/17/2006 07:20:00 0.4 0 0.4 0.4 2.2 0.8 4.6 0.7 4.7 0.9 7.2 2.6 1 7 165 165 -1.7 0 -1.4 -1.9 12/17/2006 07:30:00 0.4 0 0.4 0.4 2.4 0.7 4.2 0.7 4.2 0.7 5.7 2.6 5 11 165 165 -1.6 0 -1.4 -1.9 12/17/2006 07:40:00 0.4 0 0.4 0.4 1.9 0.7 3.8 0.7 3.9 0.6 5.3 2.6 3 7 165 165 -1.6 0 -1.2 -1.7 12/17/2006 07:50:00 0.4 0 0.4 0.4 3.9 1.1 7.2 1.5 4.7 0.9 7.2 3 346 15 165 165 -1.6 0 -1.4 -1.9 12/17/2006 08:00:00 0.4 0 0.4 0.4 3 0.9 5.7 1.5 4 1 6.5 2.3 346 13 165 165 -1.6 0 -1.4 -1.9 12/17/2006 08:10:00 0.4 0 0.4 0.4 3.7 1.2 6.1 1.1 4.8 0.8 6.8 2.6 341 15 165 165 -1.7 0 -1.4 -1.9 12/17/2006 08:20:00 0.4 0 0.4 0.4 2.8 1 5.3 0.7 4.9 1 6.8 3 8 11 165 165 -1.7 0 -1.4 -1.9 12/17/2006 08:30:00 0.4 0 0.4 0.4 3.5 1 6.8 1.5 6.1 1 8.8 1.9 0 11 165 165 -1.6 0 -1.4 -1.9 12/17/2006 08:40:00 0.4 0 0.4 0.4 3.9 1.1 8 1.9 6.6 1 10.7 4.2 6 9 165 165 -1.6 0 -1.4 -1.7 12/17/2006 08:50:00 0.4 0 0.4 0.4 4 1.1 7.6 1.5 6.4 1.3 11.1 4.2 2 11 165 165 -1.6 0 -1.4 -1.7 12/17/2006 09:00:00 0.4 0 0.4 0.4 4.2 1 7.6 2.3 6.8 1 8.8 4.2 9 9 165 165 -1.6 0 -1.4 -1.9 12/17/2006 09:10:00 0.4 0 0.4 0.4 4 1 8.4 2.3 7.6 0.7 9.9 5.7 7 7 165 165 -1.6 0 -1.4 -1.9 12/17/2006 09:20:00 0.4 0 0.4 0.4 4.1 1 8 2.3 7.7 0.8 9.5 5.3 5 7 165 165 -1.6 0 -1.4 -1.7 12/17/2006 09:30:00 0.4 0 0.4 0.4 4.2 1.1 7.6 2.3 8.5 1.1 11.5 6.1 5 6 165 165 -1.6 0 -1.4 -1.7 12/17/2006 09:40:00 0.4 0 0.4 0.4 4.6 1.3 8.4 1.9 7.9 0.8 10.3 5.7 4 9 165 165 -1.6 0 -1.2 -1.9 12/17/2006 09:50:00 0.4 0 0.4 0.4 3.7 1 7.2 2.3 7.1 0.8 9.1 4.2 3 6 165 165 -1.6 0 -1.4 -1.9 12/17/2006 10:00:00 0.4 0 0.4 0.4 4.3 1.1 7.6 1.9 6.6 1 9.1 4.2 2 10 165 165 -1.6 0 -1.4 -1.9 12/17/2006 10:10:00 0.4 0 0.4 0.4 3.1 1 6.8 1.1 4.9 0.8 7.6 2.6 2 10 165 165 -1.6 0 -1.4 -1.9 12/17/2006 10:20:00 0.4 0 0.4 0.4 4.5 1.3 8.8 2.3 7.3 0.9 10.3 4.9 1 11 165 165 -1.6 0 -1.4 -1.7 12/17/2006 10:30:00 0.4 0 0.4 0.4 6 1.2 8.4 2.6 7.4 1 10.3 4.9 348 11 165 165 -1.5 0 -1.4 -1.7 12/17/2006 10:40:00 0.4 0 0.4 0.4 7 1.1 8.8 3.4 7.8 1 10.3 5.3 342 10 165 165 -1.5 0 -1.4 -1.7 12/17/2006 10:50:00 0.4 0 0.4 0.4 6.7 1.9 14.5 3 8.7 1.5 15.3 5.3 347 13 165 165 -1.5 0 -1.4 -1.7 12/17/2006 11:00:00 0.4 0 0.4 0.4 7.4 1.2 9.5 3.4 8.9 1.1 12.6 6.1 340 10 165 165 -1.6 0 -1.4 -1.7 12/17/2006 11:10:00 0.4 0 0.4 0.4 7 1.1 8.8 3.4 8.4 0.9 10.7 5.7 343 13 165 165 -1.5 0 -1.4 -1.7 12/17/2006 11:20:00 0.4 0 0.4 0.4 7.9 1 9.1 4.6 9 1.2 11.8 5.3 334 11 165 165 -1.5 0 -1.4 -1.7 12/17/2006 11:30:00 0.4 0 0.4 0.4 7.4 1.3 9.5 4.2 9.2 1.7 13.3 5.3 345 14 165 165 -1.5 0 -1.4 -1.4 12/17/2006 11:40:00 0.4 0 0.4 0.4 8 1.2 12.2 4.6 9.2 1.5 14.1 5.7 334 13 165 165 -1.4 0 -1.2 -1.4 12/17/2006 11:50:00 0.4 0 0.4 0.4 7.2 1.4 12.2 2.6 8.4 1.7 13.7 3.8 337 13 165 165 -1.4 0 -1.2 -1.4 12/17/2006 12:00:00 0.4 0 0.4 0.4 7.6 1.5 13 3.8 8.9 1.7 13.7 4.9 338 16 165 165 -1.4 0 -1.2 -1.4 12/17/2006 12:10:00 0.4 0 0.4 0.4 8.6 1.3 13 5.3 9.9 1.5 14.1 6.8 336 12 165 165 -1.4 0 -1.2 -1.4 12/17/2006 12:20:00 5.8 4.3 15.6 0.4 10.1 2.2 17.9 4.9 11.7 2.4 20.6 6.5 332 12 314 165 -1.5 0 -1.2 -1.7 12/17/2006 12:30:00 9.4 2.5 16.1 5.3 10.7 2.5 18.3 5.7 12 2.5 18.3 6.1 336 9 334 165 -1.6 0 -1.4 -1.7 12/17/2006 12:40:00 9.5 2.4 16.4 6.1 11.2 2.2 18.7 6.8 12.5 1.9 19.9 8.8 336 9 338 165 -1.5 0 -1.4 -1.7 12/17/2006 12:50:00 10.2 2.2 15.3 5.7 11.4 2.1 15.6 6.1 12.5 1.7 16.1 6.1 341 10 336 165 -1.4 0 -1.2 -1.4 12/17/2006 13:00:00 12.5 2.1 16.4 7.2 13.7 1.8 18.7 8.4 14.4 1.9 20.6 8.8 338 7 334 165 -1.4 0 -1.2 -1.7 12/17/2006 13:10:00 9 2 14.9 6.5 10.1 2 15.6 5.3 11 1.8 17.6 6.1 341 10 340 165 -1.4 0 -1.2 -1.4 12/17/2006 13:20:00 8.9 1.9 14.1 6.8 11 2 15.3 6.1 11.9 1.5 15.6 8 343 8 332 165 -1.4 0 -1.2 -1.4 12/17/2006 13:30:00 8.5 1.5 13 6.8 10.5 1.7 14.5 7.2 11.7 1.3 15.3 8.4 341 8 339 165 -1.4 0 -1.2 -1.4 12/17/2006 13:40:00 8.4 1.6 13 6.5 10.3 1.9 14.5 6.5 11.4 1.5 15.3 7.2 344 9 347 165 -1.4 0 -1.2 -1.4 12/17/2006 13:50:00 7.5 0.4 8 6.1 9.1 1.3 13 5.7 9.9 1.4 13.3 6.8 341 9 338 165 -1.4 0 -1.2 -1.4 12/17/2006 14:00:00 8.1 1 12.2 6.8 11.1 1.5 14.9 7.6 11.7 1.2 14.9 8 344 7 338 165 -1.4 0 -1.2 -1.4 12/17/2006 14:10:00 7.6 0.4 8 5.3 9.5 1.3 13.3 6.1 10.7 1.3 14.5 6.5 339 10 338 165 -1.3 0 -1.2 -1.4 12/17/2006 14:20:00 7.8 0.8 12.2 6.8 9.5 1.2 13.3 7.2 11 1.2 14.9 8.4 341 9 330 165 -1.4 0 -1.2 -1.4 12/17/2006 14:30:00 7.6 0.6 12.2 6.1 9.3 1.3 13.7 6.8 10.1 1.4 14.1 6.8 340 9 360 165 -1.4 0 -1.2 -1.4 12/17/2006 14:40:00 8.7 1.7 13 6.8 10.4 1.6 14.1 6.5 11.6 1.3 15.3 8 341 10 328 165 -1.3 0 -1.2 -1.4 12/17/2006 14:50:00 8 1 13 6.8 10 1.5 14.1 8 11.2 1.3 14.5 8.4 334 11 334 165 -1.3 0 -1.2 -1.4 12/17/2006 15:00:00 9.3 1.8 13.7 7.2 11.3 1.6 14.5 7.2 12.8 1.2 16.1 9.1 339 9 327 165 -1.3 0 -1.2 -1.4 12/17/2006 15:10:00 9.1 1.9 13.7 6.8 10.6 1.7 14.5 8 12 1.5 15.6 9.1 333 10 334 165 -1.3 0 -1.2 -1.4 12/17/2006 15:20:00 10.3 2.1 14.9 7.2 11.6 1.6 16.1 6.8 13 1.5 16.8 8.8 334 9 341 165 -1.3 0 -1.2 -1.4 12/17/2006 15:30:00 9.9 2.3 15.3 7.2 11.5 1.9 16.4 8 12.9 1.9 17.9 8.8 336 9 8 165 -1.3 0 -1.2 -1.4 12/17/2006 15:40:00 11 2.3 15.3 7.6 12.5 1.5 16.1 8.8 13.9 1.5 17.6 9.9 336 8 336 165 -1.2 0 -1.2 -1.4 12/17/2006 15:50:00 12.3 2.2 16.1 7.2 13.3 2.2 18.7 8.8 14.6 2 21 9.1 339 9 352 165 -1.2 0 -1 -1.4 12/17/2006 16:00:00 12.8 2.4 16.4 7.2 13.8 2.4 19.1 8.8 15.3 2.4 20.6 8.8 341 10 341 165 -1.2 0 -1 -1.2 12/17/2006 16:10:00 12.9 2 16.8 7.6 13.8 2.1 19.5 8.4 15.4 2.5 21.8 9.5 341 11 345 165 -1.1 0 -0.8 -1.2 12/17/2006 16:20:00 13.2 1.7 17.2 7.6 13.9 2 19.5 9.1 15.9 2.1 22.6 11.5 340 12 325 165 -1.1 0 -0.8 -1.2 12/17/2006 16:30:00 12.1 2.4 16.4 7.2 12.8 2.4 17.9 7.6 14.7 2 19.1 9.9 342 12 338 165 -1 0 -0.8 -1.2 12/17/2006 16:40:00 11.3 2.3 15.6 6.8 11.9 1.9 17.2 6.8 14 1.7 18.7 8.8 341 14 356 165 -1 0 -0.8 -1.2 12/17/2006 16:50:00 11 2.1 15.6 7.2 12 1.7 16.8 8.4 13.7 1.6 18.7 9.5 333 13 324 165 -1.2 0 -0.8 -1.2 12/17/2006 17:00:00 13 2 16.4 7.6 13.9 2.1 17.9 8.4 15.2 2.2 20.6 10.7 342 12 338 165 -1.2 0 -1 -1.2 12/17/2006 17:10:00 12.5 2.5 17.2 7.6 13 2.2 17.9 6.8 15.3 2.4 22.6 9.9 344 13 358 165 -1.2 0 -1 -1.4 12/17/2006 17:20:00 14.1 1.5 17.2 7.2 14.4 2.3 19.9 8.4 16.7 2 21.4 9.9 346 13 355 165 -1.3 0 -1.2 -1.4 12/17/2006 17:30:00 11.8 2.3 16.8 7.2 12.6 2.2 19.1 8 14.5 2.2 21.4 9.1 335 16 350 165 -1.3 0 -1.2 -1.4 12/17/2006 17:40:00 12.7 1.9 17.2 7.6 13.5 2 20.6 8.8 15.1 2 22.9 9.5 330 14 346 165 -1.4 0 -1.2 -1.4 12/17/2006 17:50:00 12.9 2.2 17.2 7.6 13.8 2.2 20.2 9.1 15.5 2.4 22.6 10.7 336 15 349 165 -1.4 0 -1.2 -1.4 12/17/2006 18:00:00 12.4 2.1 17.2 7.6 13.3 1.6 16.8 8.4 14.9 1.7 18.7 10.7 335 13 3 165 -1.5 0 -1.4 -1.7 12/17/2006 18:10:00 12.5 1.5 17.2 8 13.1 1.5 18.7 9.1 14.9 1.5 19.5 10.3 328 11 309 165 -1.5 0 -1.4 -1.7 12/17/2006 18:20:00 12.5 1.7 16.1 7.6 13.2 1.5 16.8 8.8 14.9 1.5 19.1 11.1 325 13 304 165 -1.6 0 -1.4 -1.9 12/17/2006 18:30:00 14.4 1.3 17.2 11.1 14.7 1.5 18.7 11.1 16.4 2.1 22.1 9.9 318 8 307 165 -1.7 0 -1.4 -1.9 12/17/2006 18:40:00 14.9 1.2 17.6 11.5 15.2 1.5 20.6 12.2 17 1.9 22.1 12.2 315 8 317 165 -1.8 0 -1.4 -2.1 12/17/2006 18:50:00 15.3 1.2 17.2 10.3 15.4 1.2 17.9 10.7 17.8 1.5 20.2 11.8 314 6 309 165 -2 0 -1.7 -2.1 12/17/2006 19:00:00 15.8 0.9 17.6 13 16 1.2 19.5 13 17.4 1.5 21 13 310 7 304 165 -2 0 -1.9 -2.1 12/17/2006 19:10:00 15.8 0.8 17.6 12.6 15.8 1 19.1 13 16.9 1.6 21.8 13.7 308 5 306 165 -2.1 0 -1.9 -2.1 12/17/2006 19:20:00 15.5 0.9 17.2 12.2 15.4 1 18.3 12.2 16.6 1.6 20.6 13.3 309 7 310 165 -2.1 0 -1.9 -2.4 12/17/2006 19:30:00 15.8 0.8 17.2 13.3 15.8 1 18.7 13.3 17.1 1.2 19.9 13.3 309 6 310 165 -2.2 0 -2.1 -2.4 12/17/2006 19:40:00 14.8 1.1 17.2 12.2 14.8 1.1 17.9 12.6 16.8 1.6 21 13 312 6 315 165 -2.2 0 -2.1 -2.4 12/17/2006 19:50:00 15.4 1.2 17.2 12.2 15.5 1.3 18.3 12.6 17.7 1.7 22.1 13.7 313 6 310 165 -2.3 0 -2.1 -2.4 12/17/2006 20:00:00 15.3 1.1 17.6 11.5 15.4 1.3 19.9 11.8 17.2 1.9 22.9 12.6 312 6 315 165 -2.3 0 -2.1 -2.6 12/17/2006 20:10:00 15.8 1.1 17.2 12.6 16.1 1.3 18.7 13 18 1.8 23.3 13 313 6 328 165 -2.3 0 -2.1 -2.4 12/17/2006 20:20:00 15.7 1.1 17.6 11.8 16 1.3 19.5 12.6 17.8 1.8 22.9 12.6 312 6 316 165 -2.3 0 -2.1 -2.6 12/17/2006 20:30:00 15.9 1 17.6 13.3 16.3 1.2 19.1 13.3 18.7 1.7 23.3 12.6 315 7 313 165 -2.4 0 -2.1 -2.6 12/17/2006 20:40:00 16 1 17.9 12.2 16.5 1.3 20.6 12.6 18.7 1.7 22.6 14.1 315 6 313 165 -2.4 0 -2.1 -2.6 12/17/2006 20:50:00 15.2 1.3 17.2 11.8 15.3 1.4 18.3 11.5 17.3 2.2 21 11.1 315 6 316 165 -2.3 0 -2.1 -2.6 12/17/2006 21:00:00 14.7 1 17.2 12.2 14.7 1 17.6 12.2 16.1 1.5 19.5 11.8 314 6 314 165 -2.2 0 -2.1 -2.4 12/17/2006 21:10:00 14.6 1.1 16.8 12.2 14.6 1.1 17.6 12.2 16.3 1.9 20.6 11.1 314 5 319 165 -2.2 0 -2.1 -2.4 12/17/2006 21:20:00 14.1 0.9 16.4 11.8 14 0.8 16.4 11.8 15.3 1.2 19.5 12.2 313 6 312 165 -2.2 0 -2.1 -2.6 12/17/2006 21:30:00 14 1.1 16.8 11.1 14 1 16.8 10.7 15.7 1.3 19.1 11.1 317 6 315 165 -2.2 0 -1.9 -2.4 12/17/2006 21:40:00 14.5 1.1 17.2 11.8 14.2 0.9 16.4 11.5 15.2 1.1 17.9 11.8 313 5 313 165 -2.1 0 -1.9 -2.4 12/17/2006 21:50:00 13.3 1.1 16.1 8.8 13.1 1 15.3 9.1 14.1 1.4 17.2 9.1 314 6 299 165 -2.1 0 -1.9 -2.1 12/17/2006 22:00:00 12.4 1.9 16.8 8 12.8 1.3 17.2 9.1 14.9 1.6 19.5 11.1 322 7 325 165 -2 0 -1.9 -2.1 12/17/2006 22:10:00 14.3 1.2 17.2 10.7 14.4 1.2 17.2 10.3 16.4 1.5 19.9 12.2 322 6 321 165 -2 0 -1.9 -2.1 12/17/2006 22:20:00 13.4 0.8 15.6 11.1 13.4 0.9 15.6 10.7 15 1.2 18.3 9.9 321 8 323 165 -2 0 -1.9 -2.1 12/17/2006 22:30:00 11 2.4 16.8 8 11.5 1.7 16.1 8.4 12.8 1.6 17.9 8.8 321 9 306 165 -2.1 0 -1.9 -2.1 12/17/2006 22:40:00 9.1 1.7 14.5 6.8 10 1.3 14.1 7.2 11.7 1.3 14.9 7.6 322 9 309 165 -2.1 0 -1.9 -2.1 12/17/2006 22:50:00 10.3 1.9 14.1 7.6 11 1.4 14.5 8.4 12.4 1.6 16.1 8 318 6 319 165 -2.1 0 -1.9 -2.1 12/17/2006 23:00:00 9.1 1.4 14.5 7.6 10 1.1 14.5 8 11.1 1.3 14.5 7.2 316 7 305 165 -2.1 0 -1.9 -2.1 12/17/2006 23:10:00 10.4 1.9 14.5 8 11.2 1.3 14.1 8.8 10.9 1.5 14.9 6.8 310 7 309 165 -2 0 -1.9 -2.1 12/17/2006 23:20:00 11.1 2.4 16.8 7.6 11.9 1.7 16.4 8.4 11.8 1.8 17.9 8 311 7 321 165 -2.1 0 -1.9 -2.4 12/17/2006 23:30:00 10.9 2.2 15.6 8 11.6 1.6 15.3 8.4 11.7 2.1 16.4 7.2 310 8 291 165 -2.1 0 -1.9 -2.4 12/17/2006 23:40:00 9.4 1.5 14.1 7.6 10.3 1.2 14.1 8 10.3 1.7 14.9 6.8 310 8 311 165 -2.2 0 -1.9 -2.4 12/17/2006 23:50:00 8.8 1.1 13 4.9 9.9 1.2 13 5.3 10.8 1.4 14.5 6.8 314 8 301 165 -2.2 0 -1.9 -2.4 12/18/2006 00:00:00 9.4 1.6 13.3 7.6 10.3 1.3 13.3 8 10.5 1.7 15.3 6.5 311 8 322 165 -2.3 0 -1.9 -2.6 12/18/2006 00:10:00 9.2 1.5 13.3 7.6 10.1 1.2 13.3 7.6 9.6 1.6 13.7 6.5 308 6 305 165 -2.3 0 -2.1 -2.6 12/18/2006 00:20:00 7.8 0.6 8.8 5.7 8.1 0.8 9.5 6.1 8.1 1.4 11.8 4.6 310 8 298 165 -2.4 0 -2.1 -2.6 12/18/2006 00:30:00 6.3 1.2 8.8 3.8 6.5 1.4 9.5 4.2 6.2 1.5 9.9 3.4 307 8 311 165 -2.5 0 -2.1 -2.6 12/18/2006 00:40:00 4.9 0.7 6.5 3 5 0.6 6.5 3.4 4.7 0.7 6.8 3 305 12 305 165 -2.6 0 -2.4 -2.8 12/18/2006 00:50:00 4.6 0.7 6.5 3 4.6 0.6 6.1 3 4.3 0.9 6.5 2.6 303 9 307 165 -2.8 0 -2.6 -3 12/18/2006 01:00:00 4.9 0.8 7.2 3 5 0.8 7.6 3 4.8 1 7.6 3 305 11 296 165 -2.9 0.1 -2.8 -3.3 12/18/2006 01:10:00 5.3 0.8 8 3.4 5.4 0.8 8.4 3.4 4.9 0.9 7.2 2.6 303 9 292 165 -3.1 0 -2.8 -3.3 12/18/2006 01:20:00 5.8 0.8 7.6 3.8 5.9 0.8 8.4 3.8 5.1 0.9 7.2 3.4 300 8 292 165 -3.1 0 -2.8 -3.3 12/18/2006 01:30:00 7.3 0.8 8.8 5.3 7.6 0.9 9.5 4.9 6.8 1.3 10.3 4.2 294 8 291 165 -2.9 0 -2.8 -3.3 12/18/2006 01:40:00 7.9 0.6 8.8 5.7 8.3 0.8 9.9 5.7 7.6 1.4 11.5 4.6 293 7 287 165 -2.8 0 -2.6 -3 12/18/2006 01:50:00 8 0.6 8.8 6.1 8.3 0.8 9.5 6.1 7.2 1.2 10.3 4.6 298 7 295 165 -2.7 0 -2.6 -3 12/18/2006 02:00:00 7.8 0.6 8.8 5.7 8.1 0.8 9.9 5.7 6.8 1 9.9 4.2 298 7 290 165 -2.8 0 -2.6 -2.8 12/18/2006 02:10:00 7.4 0.6 8.8 5.7 7.5 0.7 9.5 5.7 6.5 1 9.9 4.6 295 7 296 165 -2.8 0 -2.6 -3 12/18/2006 02:20:00 7.1 0.7 8.8 4.9 7.2 0.8 9.5 4.9 7.2 1 10.3 4.6 288 7 290 165 -2.8 0 -2.6 -3 12/18/2006 02:30:00 6.9 0.6 8 5.3 6.9 0.6 8.4 5.3 6.8 1 9.1 4.2 289 5 286 165 -2.9 0 -2.6 -3 12/18/2006 02:40:00 7.9 0.6 9.1 6.1 8.1 0.9 9.9 6.1 7.5 1.3 11.5 4.6 291 5 298 165 -2.8 0 -2.6 -3 12/18/2006 02:50:00 8.7 0.6 12.2 7.6 9.2 0.6 11.8 7.6 9.4 1.4 12.6 6.1 289 5 286 165 -2.6 0 -2.6 -2.8 12/18/2006 03:00:00 8.4 0.6 11.8 6.5 8.9 0.9 11.5 6.5 8 1.5 11.8 4.9 293 5 294 165 -2.6 0 -2.6 -2.8 12/18/2006 03:10:00 8.9 0.8 13 7.6 9.6 0.8 12.6 7.6 9.1 1.5 13.3 5.7 292 7 284 165 -2.6 0 -2.6 -2.8 12/18/2006 03:20:00 8.9 0.6 12.6 8 9.6 0.5 12.2 8 9.6 1.3 12.2 6.5 291 5 287 165 -2.5 0 -2.4 -2.6 12/18/2006 03:30:00 8.6 0.3 9.1 7.2 9 0.6 10.7 7.2 8.3 1.5 11.8 5.3 292 5 284 165 -2.5 0 -2.1 -2.6 12/18/2006 03:40:00 9 0.8 12.6 7.6 9.6 0.7 12.2 8 8.4 1.5 13 5.7 295 5 296 165 -2.5 0 -2.1 -2.6 12/18/2006 03:50:00 8.6 0.3 9.1 6.8 8.9 0.6 9.9 6.5 7.3 1.1 11.1 5.3 297 4 294 165 -2.5 0 -2.4 -2.6 12/18/2006 04:00:00 8.9 0.8 12.6 7.2 9.2 0.8 12.2 7.2 7.3 1 11.1 5.3 300 5 300 165 -2.6 0 -2.6 -2.8 12/18/2006 04:10:00 8.7 0.5 11.5 5.7 9.1 0.7 11.5 6.8 8.5 1.4 11.8 5.7 290 9 307 165 -2.2 0.2 -1.9 -2.8 12/18/2006 04:20:00 8.9 0.8 12.2 7.2 9 0.7 11.8 7.2 7.3 1.1 11.1 4.9 298 5 310 165 -2.2 0 -1.9 -2.6 12/18/2006 04:30:00 9.4 1 13.3 8.4 9.6 0.7 12.6 8 8.1 1.5 13.7 5.7 296 5 286 165 -2.1 0.1 -1.9 -2.4 12/18/2006 04:40:00 9.3 0.8 12.6 8.4 9.7 0.6 12.2 8 8.4 1.2 12.2 6.1 296 6 290 165 -2.2 0 -1.9 -2.6 12/18/2006 04:50:00 10 1.3 13 8 10 0.9 12.6 8 8.8 1.3 13.7 6.1 295 5 294 165 -2.2 0 -1.9 -2.6 12/18/2006 05:00:00 10.7 1.4 13.3 8.8 10.4 0.9 12.6 8.8 8.9 1.3 13 6.1 296 6 301 165 -2.2 0 -1.9 -2.6 12/18/2006 05:10:00 12.9 1.7 15.6 8.8 12.3 1.4 15.3 9.1 9.6 1.5 13.7 6.5 297 5 296 165 -2.4 0 -2.1 -2.6 12/18/2006 05:20:00 12.4 1.5 15.3 8.8 11.8 1.3 14.5 8.4 9.9 1.4 14.9 6.8 297 7 294 165 -2.4 0 -2.1 -2.6 12/18/2006 05:30:00 12.1 1 14.1 8.8 11.6 1 13.7 9.1 10.2 1.5 14.1 6.1 292 5 287 165 -2.5 0 -2.1 -2.6 12/18/2006 05:40:00 11.8 1.2 14.1 8.8 11.3 1 13.7 8.8 9.5 1.5 13.3 6.5 294 5 291 165 -2.5 0 -2.1 -2.8 12/18/2006 05:50:00 12.9 0.8 14.5 9.5 12.4 0.9 14.1 9.9 10.2 1.4 14.1 6.5 294 5 292 165 -2.4 0 -2.1 -2.6 12/18/2006 06:00:00 12.8 1.1 15.3 9.1 12.1 1.1 14.5 9.5 9.9 1.5 13.7 6.8 295 5 292 165 -2.4 0.1 -2.1 -2.6 12/18/2006 06:10:00 13.1 0.8 14.9 9.9 12.6 0.8 14.5 9.9 11.8 1.3 14.5 8 289 3 286 165 -2.2 0 -2.1 -2.6 12/18/2006 06:20:00 13.6 1 16.4 11.1 13.1 1 16.1 10.3 11.4 1.7 16.4 7.2 292 4 285 165 -2.2 0 -1.9 -2.4 12/18/2006 06:30:00 12.6 0.6 14.1 11.5 12 0.8 13.7 9.9 10 1.4 13.7 6.8 295 4 292 165 -2 0.1 -1.7 -2.4 12/18/2006 06:40:00 12.6 1 15.3 9.9 11.9 1.2 14.5 9.5 9.6 1.7 15.3 6.8 297 6 296 165 -2 0 -1.7 -2.1 12/18/2006 06:50:00 12.4 1 14.1 9.9 11.6 1 13.3 9.9 9.7 1.5 13.7 6.8 303 6 292 165 -2.2 0 -1.9 -2.6 12/18/2006 07:00:00 12 0.9 16.1 9.1 11.2 0.8 14.9 9.1 10.5 1.5 13.3 7.2 309 6 298 165 -2.5 0.1 -2.1 -2.8 12/18/2006 07:10:00 12.4 1.1 15.3 9.1 11.7 1.1 14.1 9.1 11.2 1.5 14.5 7.2 309 6 314 165 -2.5 0 -2.1 -2.8 12/18/2006 07:20:00 12.4 1.4 15.6 9.1 12 1.4 15.3 9.1 11.3 1.7 15.3 7.6 310 7 306 165 -2.4 0.1 -2.1 -2.8 12/18/2006 07:30:00 12.8 1.2 15.6 9.5 12.3 1.2 14.9 9.9 11.4 1.5 15.3 7.6 310 7 314 165 -2.6 0.1 -2.1 -2.8 12/18/2006 07:40:00 12 1.2 14.9 8.8 11.5 1.2 14.5 8.4 9.6 1.3 14.1 7.2 302 8 304 165 -2.4 0 -2.1 -2.6 12/18/2006 07:50:00 12.4 1.6 16.1 8.8 12.1 1.6 15.6 8 10.2 1.7 14.9 6.1 299 9 287 165 -2.2 0.1 -1.9 -2.6 12/18/2006 08:00:00 12.1 1.5 15.3 8.8 11.7 1.5 15.3 8.4 9.7 1.7 14.9 5.7 301 7 301 165 -1.9 0.1 -1.4 -2.1 12/18/2006 08:10:00 12.3 1.4 15.6 9.1 11.9 1.5 15.3 8.8 9.7 1.3 14.1 6.5 301 8 305 165 -2.1 0 -1.4 -2.4 12/18/2006 08:20:00 13.6 1.3 16.8 9.1 13.2 1.3 16.4 9.1 10.8 1.6 15.3 7.2 303 7 307 165 -2.1 0 -1.9 -2.4 12/18/2006 08:30:00 12.8 1 15.6 10.3 12.5 1 15.6 10.3 10.6 1.5 14.5 7.2 305 6 302 165 -2.2 0 -1.9 -2.6 12/18/2006 08:40:00 13.4 1.3 16.4 10.3 13.1 1.5 16.1 10.3 10.8 1.3 14.1 8 305 5 304 165 -2.3 0.1 -1.9 -2.6 12/18/2006 08:50:00 13.1 0.9 15.3 10.3 12.8 1 14.9 10.3 12 1.5 15.3 8 310 6 307 165 -2.1 0 -1.9 -2.4 12/18/2006 09:00:00 13.6 1.2 16.8 9.9 13.3 1.2 16.4 10.3 13.1 1.7 16.4 8 311 8 313 165 -2.4 0.1 -1.9 -2.6 12/18/2006 09:10:00 14.2 1.1 16.8 11.8 13.9 1.1 16.4 11.5 14 1.3 16.8 10.7 315 6 313 165 -2.6 0 -2.1 -2.8 12/18/2006 09:20:00 14.6 1.2 19.5 11.8 14.3 1.2 19.1 11.1 14.4 1.4 18.7 9.9 316 5 309 165 -2.5 0 -2.4 -2.8 12/18/2006 09:30:00 14.8 1 17.2 11.8 14.5 1 17.2 11.5 14.6 1.1 17.2 10.7 315 5 322 165 -2.5 0 -2.4 -2.8 12/18/2006 09:40:00 14.6 1.1 17.2 11.8 14.4 1.1 16.8 11.8 14 1.3 17.2 9.9 313 7 312 165 -2.5 0 -2.4 -2.8 12/18/2006 09:50:00 14.9 1.2 18.3 11.8 14.7 1.2 17.9 11.1 14.2 1.5 17.9 9.5 312 6 316 165 -2.4 0 -2.1 -2.6 12/18/2006 10:00:00 14.9 1.1 17.6 12.2 14.7 1.1 17.6 12.2 14.3 1.1 17.6 11.1 312 6 313 165 -2.2 0.2 -1.9 -2.6 12/18/2006 10:10:00 15.3 1.1 17.9 12.6 15.1 1.1 17.9 11.8 14.8 1.2 17.6 11.5 314 6 310 165 -1.9 0 -1.7 -2.1 12/18/2006 10:20:00 14.2 1.3 19.1 11.1 14 1.3 18.7 11.1 12.9 1.9 17.2 7.6 310 7 310 165 -1.8 0.1 -1.4 -2.1 12/18/2006 10:30:00 13.8 1.5 17.6 10.3 13.7 1.5 17.6 10.3 12 1.7 16.1 8.4 308 6 308 165 -1.8 0 -1.4 -2.1 12/18/2006 10:40:00 12.6 1.2 15.6 8.8 12.4 1.2 15.3 8.8 11 1.7 14.5 6.8 307 8 297 165 -1.7 0 -1.4 -1.9 12/18/2006 10:50:00 10.7 1.3 14.9 8 10.6 1.3 14.5 8 9.7 1.3 14.1 6.5 311 6 311 165 -1.6 0 -1.4 -1.9 12/18/2006 11:00:00 8.3 0.9 11.1 6.5 8.2 0.9 11.1 6.1 7.4 1 9.9 4.9 308 8 302 165 -1.4 0 -1.2 -1.7 12/18/2006 11:10:00 7.2 1 9.1 4.6 7 1 9.1 4.6 6.2 1 8.8 3.8 309 8 308 165 -1.4 0 -1.2 -1.7 12/18/2006 11:20:00 6.1 1 8.8 3.4 6 1 8.4 3 5.4 0.9 7.6 2.3 307 10 310 165 -1.3 0 -1 -1.4 12/18/2006 11:30:00 6.6 1 9.1 3.8 6.5 1 8.8 3.8 6.2 1 9.1 3.4 311 6 319 165 -1 0.1 -0.8 -1.2 12/18/2006 11:40:00 7.3 0.9 9.5 5.3 7.2 0.9 9.9 4.9 6.8 0.7 8.8 4.9 312 8 307 165 -1.3 0.2 -0.8 -2.1 12/18/2006 11:50:00 7.8 0.8 9.9 6.1 7.7 0.8 9.5 6.1 6.2 1 9.1 4.6 303 6 308 165 -1.4 0.1 -1.2 -1.9 12/18/2006 12:00:00 8.3 1 11.1 6.1 8.2 1 11.1 5.7 6.4 1 9.5 4.2 303 6 304 165 -1.8 0.1 -1.2 -2.4 12/18/2006 12:10:00 7.9 1.1 10.3 4.6 7.9 1.2 10.3 4.2 6.4 1.2 10.3 3.4 294 8 304 165 -1.7 0.2 -1.2 -2.1 12/18/2006 12:20:00 7.3 1.1 9.9 4.2 7.3 1.1 9.9 4.6 6.2 1.1 8.8 3.4 292 8 293 165 -1.5 0.1 -1.2 -1.9 12/18/2006 12:30:00 6.8 1.1 9.1 3.4 6.7 1.1 9.1 3.4 5.5 1 8.4 3.4 295 10 302 165 -1.2 0.2 -0.8 -1.9 12/18/2006 12:40:00 5.2 1 7.2 3 5.1 1 7.6 3 4.2 0.7 6.1 1.9 295 11 300 165 -0.9 0 -0.8 -1.2 12/18/2006 12:50:00 6.1 1 8 3.8 6 1 8.4 3.8 5 1.1 8.8 2.3 298 9 292 165 -0.9 0 -0.5 -1.2 12/18/2006 13:00:00 5.8 1 8.8 3.8 5.8 1 9.1 3.4 5.2 1 8.8 2.6 288 8 285 165 -0.9 0.1 -0.3 -1.2 12/18/2006 13:10:00 4.2 0.9 6.5 2.3 4.2 0.9 6.5 2.3 4.1 0.8 6.5 2.6 282 8 289 165 -0.9 0 -0.5 -1.2 12/18/2006 13:20:00 3.7 0.6 4.9 1.9 3.7 0.6 4.9 2.3 3.4 0.5 5.3 2.3 281 12 287 165 -0.8 0.1 -0.3 -1 12/18/2006 13:30:00 2.8 0.9 5.3 0.7 2.8 0.8 5.3 0.7 2.6 0.9 5.3 1.1 280 10 281 165 -0.7 0.1 -0.1 -1 12/18/2006 13:40:00 1.9 0.6 3.4 0.7 2 0.6 3.4 0.7 2.1 0.5 3 0.7 257 16 276 165 -0.1 0.2 0.7 -0.5 12/18/2006 13:50:00 1.2 0.5 3 0.4 1.1 0.5 2.6 0.4 1.1 0.5 2.3 0.4 269 38 293 165 0.8 0.1 1.4 0.4 12/18/2006 14:00:00 2 0.8 3.8 0.4 1.8 0.7 3.4 0.4 1.9 0.6 3.4 0.4 272 22 297 165 0.6 0.3 1.1 0.2 12/18/2006 14:10:00 0.4 0.2 1.5 0.4 0.4 0.2 1.5 0.4 0.5 0.4 1.9 0.4 245 21 255 165 1.4 0.8 2.8 0.2 12/18/2006 14:20:00 1.3 0.5 2.6 0.4 1.2 0.5 2.3 0.4 1.5 0.6 3 0.4 197 11 172 165 2 0.6 3.3 0.9 12/18/2006 14:30:00 1.1 0.5 1.9 0.4 1 0.5 1.9 0.4 1.4 0.4 2.3 0.4 188 6 187 165 0.9 0 1.1 0.9 12/18/2006 14:40:00 2.3 0.4 3 1.1 2.2 0.4 3 1.1 2.4 0.4 3.4 1.5 190 6 193 165 0.3 0.2 0.9 -0.1 12/18/2006 14:50:00 3.4 0.6 5.3 2.3 3.3 0.6 5.3 2.3 3.4 0.6 5.3 2.6 185 13 206 165 -0.3 0.1 0.2 -0.5 12/18/2006 15:00:00 3.8 0.6 5.3 2.6 3.8 0.6 4.9 2.6 4 0.5 4.9 2.6 206 8 201 165 -0.6 0 -0.1 -0.8 12/18/2006 15:10:00 3.9 0.5 4.9 2.6 3.9 0.4 4.9 2.6 4 0.4 4.9 2.6 204 6 210 165 -0.8 0.1 -0.5 -1 12/18/2006 15:20:00 3.3 0.4 4.2 1.9 3.3 0.4 4.2 2.3 3.3 0.5 4.6 2.3 212 7 204 165 -1 0 -0.5 -1.2 12/18/2006 15:30:00 2.7 0.5 3.8 1.5 2.7 0.5 3.8 1.1 2.7 0.4 3.8 1.9 234 13 226 165 -1.3 0 -0.8 -1.4 12/18/2006 15:40:00 1 0.5 2.3 0.4 1.1 0.6 2.3 0.4 1.2 0.4 2.3 0.4 279 32 247 165 -1.3 0 -1 -1.4 12/18/2006 15:50:00 0.8 0.6 2.3 0.4 0.7 0.5 2.3 0.4 0.9 0.6 2.3 0.4 309 72 342 165 -1 0 -0.8 -1.2 12/18/2006 16:00:00 1 0.7 2.6 0.4 1 0.7 2.6 0.4 1.2 0.7 2.6 0.4 159 29 142 165 -1.7 0.4 -1 -2.6 12/18/2006 16:10:00 0.6 0.4 1.5 0.4 0.6 0.3 1.5 0.4 0.6 0.4 1.9 0.4 195 51 165 165 -2.4 0.1 -2.1 -2.8 12/18/2006 16:20:00 1.3 0.5 2.3 0.4 1.4 0.5 2.3 0.4 1.6 0.5 2.6 0.7 316 24 329 165 -2.8 0 -2.6 -3.3 12/18/2006 16:30:00 2.2 0.4 3 0.7 1.5 0.5 2.6 0.4 2.4 0.4 3 1.5 354 5 358 165 -3 0 -2.6 -3.3 12/18/2006 16:40:00 0.5 0.3 1.5 0.4 0.4 0.2 1.1 0.4 0.9 0.5 1.9 0.4 358 0 358 165 -2.5 0.3 -1.9 -3 12/18/2006 16:50:00 0.7 0.5 2.3 0.4 0.9 0.5 2.3 0.4 1.1 0.5 2.3 0.4 109 32 121 165 -2.1 0.1 -1.9 -2.6 12/18/2006 17:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0.1 1.1 0.4 114 3 165 165 -2 0.1 -1.9 -2.4 12/18/2006 17:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 113 0 165 165 -3 0.4 -2.1 -3.9 12/18/2006 17:20:00 1.3 0.5 2.6 0.4 1.4 0.6 2.3 0.4 1.6 0.6 3 0.4 169 36 172 165 -3.1 0.4 -2.6 -4.2 12/18/2006 17:30:00 0.8 0.5 1.9 0.4 0.9 0.6 1.9 0.4 1.3 0.6 2.3 0.4 206 3 199 165 -2.7 0.2 -2.1 -3.5 12/18/2006 17:40:00 0.8 0.4 1.5 0.4 0.7 0.4 1.5 0.4 0.9 0.5 1.9 0.4 20 102 63 165 -2.6 0.2 -2.1 -3.3 12/18/2006 17:50:00 0.7 0.3 1.5 0.4 0.9 0.3 1.5 0.4 1.1 0.2 1.5 0.7 45 8 46 165 -2 0.2 -1.4 -2.6 12/18/2006 18:00:00 0.6 0.4 1.5 0.4 0.9 0.3 1.5 0.4 1.2 0.2 1.9 0.7 124 9 94 165 -2 0.2 -1.4 -2.6 12/18/2006 18:10:00 1.2 0.3 1.9 0.7 1.2 0.3 1.9 0.7 1.6 0.4 2.6 1.1 140 9 156 165 -2.2 0.1 -1.9 -2.6 12/18/2006 18:20:00 2.4 0.2 3 1.9 2.3 0.2 3 1.5 2.6 0.2 3 1.9 161 9 152 165 -2.3 0.1 -1.9 -2.8 12/18/2006 18:30:00 2.3 0.4 3 1.5 2.2 0.4 3 1.1 2.5 0.3 3 1.9 160 7 162 165 -2.5 0.3 -1.9 -3.3 12/18/2006 18:40:00 2.4 0.7 3.4 0.7 2.2 0.6 3.4 0.7 2.6 0.4 3.8 1.9 166 6 164 165 -2.6 0.2 -2.4 -3.3 12/18/2006 18:50:00 2.9 0.6 4.2 1.9 2.8 0.6 3.8 1.5 3 0.5 4.2 1.9 155 6 143 165 -2.8 0 -2.4 -3.3 12/18/2006 19:00:00 2.6 0.4 3.4 1.5 2.4 0.4 3.4 1.5 2.6 0.4 3.4 1.9 161 4 158 165 -2.7 0 -2.4 -3 12/18/2006 19:10:00 2.1 0.5 3 1.1 1.9 0.5 2.6 0.7 2 0.4 3 1.1 157 5 155 165 -2.9 0 -2.6 -3.3 12/18/2006 19:20:00 1.6 0.9 3 0.4 1.5 0.8 3 0.4 1.7 0.9 3 0.4 166 8 159 165 -2.5 0.1 -2.1 -3 12/18/2006 19:30:00 1.4 0.8 3 0.4 1.2 0.8 3 0.4 1.6 0.8 3 0.4 152 13 164 165 -2.6 0.1 -2.4 -3.3 12/18/2006 19:40:00 2.6 0.4 3.8 1.5 2.4 0.4 3.8 1.1 2.7 0.4 3.4 1.9 155 7 166 165 -2.6 0.2 -2.1 -3.3 12/18/2006 19:50:00 3.3 0.4 4.2 2.3 3.1 0.4 3.8 1.9 3 0.4 3.8 2.3 154 3 151 165 -2.8 0 -2.6 -3.3 12/18/2006 20:00:00 2.8 0.3 3.8 2.3 2.6 0.3 3.4 2.3 2.8 0.3 3.4 1.9 158 4 162 165 -2.6 0 -2.6 -3.3 12/18/2006 20:10:00 2.3 0.6 3.4 1.1 2.1 0.6 3.4 0.7 2.3 0.5 3.4 1.1 155 4 159 165 -2.8 0 -2.6 -3 12/18/2006 20:20:00 1.9 0.3 2.6 1.1 1.6 0.4 2.6 0.7 1.8 0.3 2.6 1.1 156 7 156 165 -2.7 0 -2.4 -3 12/18/2006 20:30:00 1.8 0.3 2.6 1.1 1.4 0.4 2.3 0.7 1.6 0.2 2.3 1.1 177 5 189 165 -2.4 0 -2.1 -3 12/18/2006 20:40:00 2.5 0.2 3 2.3 2.4 0.3 3 1.9 2.5 0.3 3.4 1.5 194 3 192 165 -2 0.1 -1.7 -2.6 12/18/2006 20:50:00 2.5 0.5 3.4 1.1 2.4 0.7 3.4 0.7 2.5 0.6 3.8 1.1 197 5 198 165 -2 0.1 -1.7 -2.6 12/18/2006 21:00:00 2.1 0.4 2.6 1.1 1.7 0.5 2.6 0.4 2.1 0.5 3 1.1 192 5 195 165 -2 0.1 -1.7 -2.6 12/18/2006 21:10:00 1.7 0.6 3 0.7 1.4 0.8 3 0.4 2 0.5 3.4 1.1 168 14 151 165 -1.9 0.1 -1.7 -2.4 12/18/2006 21:20:00 1.6 0.6 3 0.4 1.3 0.7 3 0.4 1.9 0.5 3.4 0.7 160 8 148 165 -2 0.1 -1.7 -2.4 12/18/2006 21:30:00 2.3 0.3 3 1.5 2.1 0.3 2.6 1.1 2.4 0.3 3 1.9 146 5 146 165 -2 0 -1.7 -2.1 12/18/2006 21:40:00 2.7 0.4 3.4 1.9 2.5 0.5 3.4 1.5 2.6 0.5 3.8 1.5 149 3 146 165 -1.7 0 -1.4 -1.9 12/18/2006 21:50:00 2.7 0.3 3.4 1.9 2.7 0.3 3.4 1.9 2.8 0.4 3.8 1.9 133 10 150 165 -1.5 0 -1.2 -1.9 12/18/2006 22:00:00 2.2 0.6 3.4 0.7 2.1 0.7 3.4 0.4 2.3 0.4 3.4 1.5 129 6 131 165 -1.4 0 -1.2 -1.4 12/18/2006 22:10:00 2.1 0.4 3.4 1.1 2.1 0.4 3.4 1.1 2.3 0.4 3.4 1.1 117 8 112 165 -1.5 0 -1.2 -1.4 12/18/2006 22:20:00 1.7 0.4 2.6 0.7 1.6 0.4 2.6 0.7 2 0.4 3 1.5 124 6 124 165 -1.6 0 -1.2 -1.9 12/18/2006 22:30:00 1.8 0.4 2.6 1.1 1.9 0.4 2.6 0.7 2.1 0.3 2.6 1.5 108 6 107 165 -1.8 0.1 -1.4 -2.1 12/18/2006 22:40:00 2.5 0.6 3.8 1.1 2.6 0.6 4.2 1.1 2.6 0.5 4.2 1.5 110 8 110 165 -1.4 0 -1.2 -1.4 12/18/2006 22:50:00 2.8 0.7 4.6 1.5 2.9 0.7 4.9 1.5 3.2 0.6 4.9 2.3 94 7 90 165 -1.4 0 -1.2 -1.7 12/18/2006 23:00:00 3.9 0.3 4.6 2.6 4.1 0.4 4.6 2.6 4.2 0.4 4.9 3 91 6 102 165 -1.8 0.2 -1.2 -2.1 12/18/2006 23:10:00 3.7 0.3 4.6 2.6 3.8 0.4 4.6 3 3.9 0.4 4.6 3 88 5 88 165 -2 0 -1.7 -2.1 12/18/2006 23:20:00 4.1 0.5 4.9 2.6 4.2 0.5 5.3 2.6 4.2 0.5 5.3 3 94 5 90 165 -1.7 0.3 -1 -1.9 12/18/2006 23:30:00 4.5 0.3 5.3 3.4 4.6 0.3 5.3 3.4 4.7 0.3 5.7 3.8 108 7 98 165 -0.9 0.1 -0.8 -1.2 12/18/2006 23:40:00 4.5 0.4 5.7 3.4 4.6 0.4 5.7 3.4 4.6 0.4 5.7 3 105 5 112 165 -0.8 0 -0.5 -1.2 12/18/2006 23:50:00 4.9 0.6 6.8 3.4 4.9 0.6 6.5 3.4 4.9 0.7 6.5 3.4 121 8 128 165 -0.8 0.1 -0.5 -1.4 12/19/2006 00:00:00 4.1 0.6 5.7 2.6 4.1 0.6 5.7 2.6 4 0.5 5.3 2.6 120 7 122 165 -1 0.1 -0.8 -1.7 12/19/2006 00:10:00 3.8 0.5 5.3 2.3 3.8 0.5 5.3 2.3 3.9 0.4 5.3 3 123 5 121 165 -0.9 0.1 -0.8 -1.7 12/19/2006 00:20:00 3 0.5 4.2 1.9 3.1 0.5 4.2 1.9 3.2 0.5 4.2 1.9 121 4 128 165 -0.9 0.1 -0.5 -1.4 12/19/2006 00:30:00 2.7 0.3 3.4 1.9 2.6 0.4 3.8 1.5 2.9 0.3 3.8 2.3 126 6 125 165 -0.7 0 -0.5 -1.2 12/19/2006 00:40:00 2.9 0.3 3.8 1.9 3 0.3 3.8 1.9 2.9 0.4 3.8 1.9 112 7 108 165 -0.5 0 -0.3 -1 12/19/2006 00:50:00 5.4 1.7 8.8 3 5.5 1.7 9.1 3.4 5.4 1.7 8.8 3 105 9 99 165 -0.6 0.1 -0.3 -1 12/19/2006 01:00:00 7.4 0.8 9.5 6.1 7.5 0.8 9.5 5.7 7 0.7 9.1 5.3 118 13 116 165 -1.2 0 -0.8 -1.4 12/19/2006 01:10:00 3.6 2.2 7.2 0.4 3.4 2.2 7.2 0.4 3.8 2 7.2 0.7 139 22 128 165 -1.1 0 -0.8 -1.2 12/19/2006 01:20:00 3.6 1.3 6.1 1.9 3.7 1.4 6.1 1.9 3.6 1.4 6.1 1.9 88 6 94 165 -1.1 0 -0.8 -1.2 12/19/2006 01:30:00 5.4 0.3 6.1 4.9 5.5 0.3 6.5 4.9 5.6 0.3 6.1 4.9 89 3 88 165 -0.7 0 -0.5 -1 12/19/2006 01:40:00 5.6 0.3 6.1 4.9 5.8 0.2 6.5 5.3 5.7 0.3 6.5 4.9 92 2 91 165 -0.3 0.1 -0.1 -0.5 12/19/2006 01:50:00 6.2 0.8 8 3.4 6.4 0.8 8.4 3.8 6.2 0.8 8 3.8 91 5 89 165 -0.1 0.1 0.2 -0.5 12/19/2006 02:00:00 3.5 0.7 4.9 1.5 3.6 0.7 5.3 1.5 3.4 0.8 4.9 1.1 93 10 114 165 -0.5 0 -0.1 -0.8 12/19/2006 02:10:00 4.6 0.7 6.1 3 4.6 0.7 6.5 3 4.5 0.5 6.1 3.4 70 8 78 165 -0.4 0 -0.3 -0.5 12/19/2006 02:20:00 4.4 0.7 6.8 3 4.4 0.7 7.2 3 4.2 0.5 6.1 3 62 10 73 165 -0.6 0 -0.5 -0.8 12/19/2006 02:30:00 4.3 0.9 6.8 2.3 4.3 1 7.2 1.9 4.1 0.6 6.1 2.6 70 14 111 165 -0.6 0 -0.5 -0.8 12/19/2006 02:40:00 5.1 1.1 7.6 2.6 5.2 1.2 8 2.6 4.9 1 7.2 3 76 12 87 165 -0.6 0.1 -0.3 -1 12/19/2006 02:50:00 7.1 1.2 9.5 3.4 7.2 1.3 9.5 3.4 6.9 1.2 9.5 3.4 87 9 90 165 -0.1 0.3 0.4 -0.8 12/19/2006 03:00:00 7.5 1.1 9.9 3.8 7.7 1.1 9.9 4.2 7.2 1 9.5 4.6 89 9 92 165 0.2 0 0.7 0.2 12/19/2006 03:10:00 8.1 0.9 10.3 5.7 8.3 1 10.7 5.7 7.8 0.9 10.3 5.3 92 7 101 165 0.5 0 0.7 0.2 12/19/2006 03:20:00 7.1 1.3 9.9 4.2 7.2 1.3 10.3 4.2 6.8 1.2 9.9 4.6 85 11 96 165 0.4 0.1 0.7 0.2 12/19/2006 03:30:00 8 0.9 10.3 6.1 8.1 0.9 11.1 6.1 7.7 0.9 10.7 6.1 73 7 76 165 0.2 0 0.4 -0.1 12/19/2006 03:40:00 7.5 1.1 11.1 4.9 7.6 1.2 11.5 5.3 7.2 1 10.3 4.9 68 8 65 165 0.1 0 0.4 -0.1 12/19/2006 03:50:00 7.9 1 10.7 5.3 8 1 10.7 5.3 7.5 0.9 9.9 5.3 67 8 43 165 0 0 0.2 -0.1 12/19/2006 04:00:00 7.9 1 10.3 5.7 8 1 11.1 5.7 7.5 1 10.7 4.9 66 8 78 165 0 0 0.2 -0.3 12/19/2006 04:10:00 7.4 1.1 10.7 5.3 7.5 1.1 10.7 4.9 7 1 9.9 4.6 62 9 64 165 0.1 0 0.2 -0.1 12/19/2006 04:20:00 8 1.4 11.5 4.9 8 1.5 11.8 4.9 7.7 1.3 11.5 4.6 61 10 61 165 0.2 0 0.2 0.2 12/19/2006 04:30:00 7.4 1.1 10.3 4.6 7.4 1.2 11.1 4.2 7.1 1.1 10.7 4.2 49 9 66 165 0.2 0 0.7 -0.1 12/19/2006 04:40:00 8.8 1.2 11.5 5.7 8.8 1.3 11.5 5.3 8.3 1.3 12.2 5.7 49 10 51 165 0.4 0 0.7 0.2 12/19/2006 04:50:00 9.2 1.3 13 6.1 9.3 1.4 13.7 5.7 8.6 1.3 12.6 5.7 55 9 50 165 0.5 0 0.9 0.2 12/19/2006 05:00:00 9.7 1.5 13.3 5.7 9.8 1.5 13.3 6.1 9.2 1.3 13 5.3 54 9 60 165 0.5 0 0.9 0.2 12/19/2006 05:10:00 9.8 1.5 13.7 6.1 9.8 1.5 14.1 6.1 9.4 1.3 13.7 6.5 43 8 39 165 0.5 0 0.7 0.4 12/19/2006 05:20:00 10.3 1.5 14.5 6.5 10.3 1.6 14.1 6.1 10.1 1.7 14.1 6.1 45 10 39 165 0.6 0 0.9 0.7 12/19/2006 05:30:00 10.1 2.2 14.5 5.3 10.1 2.2 14.9 5.3 9.4 2.1 14.5 4.9 49 11 51 165 0.7 0 0.9 0.7 12/19/2006 05:40:00 11.4 1.9 16.4 7.2 11.4 2 16.8 6.8 11.1 1.9 17.2 7.2 38 9 39 165 0.7 0 0.9 0.7 12/19/2006 05:50:00 11.7 1.6 15.3 7.6 11.7 1.6 15.3 7.2 11.3 1.5 15.3 7.6 37 8 42 165 0.7 0 0.9 0.7 12/19/2006 06:00:00 11.9 1.7 15.3 8 11.9 1.7 15.6 8 11.2 1.9 16.1 6.8 37 9 47 165 0.8 0 1.1 0.7 12/19/2006 06:10:00 11.8 1.7 16.1 7.2 11.7 1.7 16.1 7.2 11.6 1.8 15.6 7.2 37 9 43 165 0.8 0 0.9 0.7 12/19/2006 06:20:00 14 2.2 19.5 9.1 14 2.3 19.9 9.1 13.7 2.2 19.9 8.8 35 7 37 165 0.8 0 1.1 0.4 12/19/2006 06:30:00 13.4 2.1 18.7 7.6 13.1 2.2 18.7 7.6 12.9 1.9 17.6 8.4 28 9 29 165 0.5 0 0.9 0.4 12/19/2006 06:40:00 14.3 2 18.7 9.1 14.2 2.1 19.1 8.8 13.9 2 19.1 9.9 35 8 44 165 0.8 0.1 1.1 0.7 12/19/2006 06:50:00 13.6 1.9 17.6 8.4 13.6 2 17.9 8.4 13.2 1.9 18.3 8.8 35 8 34 165 0.8 0 0.9 0.9 12/19/2006 07:00:00 13.8 2.3 18.7 8 13.6 2.3 18.7 7.2 13.3 2.4 19.1 8 34 10 41 165 0.9 0 1.1 0.9 12/19/2006 07:10:00 13.9 2.5 21.8 8.4 13.9 2.6 21.8 8.8 13.6 2.6 19.9 8.4 36 8 39 165 1 0 1.4 0.9 12/19/2006 07:20:00 12.9 2.3 18.7 7.2 12.9 2.4 18.7 7.2 12.5 2.3 18.7 7.6 42 12 41 165 1.1 0 1.4 0.9 12/19/2006 07:30:00 13.1 2.4 17.9 8 13.1 2.5 18.3 7.6 12.7 2.5 18.7 6.8 40 11 25 165 1.1 0 1.4 0.9 12/19/2006 07:40:00 13.7 2.1 21.4 9.1 13.6 2.2 21.8 7.2 13.4 1.9 21.4 9.1 41 11 44 165 1.1 0 1.4 0.9 12/19/2006 07:50:00 15.7 2.6 21 9.9 15.7 2.7 21.4 9.5 15.3 2.6 21.8 8.8 36 9 46 165 1 0 1.4 0.9 12/19/2006 08:00:00 15.6 2.5 22.9 9.1 15.6 2.5 23.3 9.1 15.2 2.6 23.3 9.5 38 9 44 165 1.1 0 1.4 0.9 12/19/2006 08:10:00 17.2 2.9 23.7 10.3 17.1 3.1 23.7 10.3 16.6 3.2 23.7 7.6 33 9 19 165 1.1 0 1.4 0.9 12/19/2006 08:20:00 17.6 2.8 23.7 9.9 17.6 2.9 23.7 9.9 17 2.8 24.4 11.1 36 10 39 165 1 0 1.4 0.9 12/19/2006 08:30:00 17.2 2.3 24.4 9.9 17.1 2.4 24.4 9.5 16.5 2.3 22.9 10.3 36 11 37 165 1 0.1 1.4 0.9 12/19/2006 08:40:00 16.5 2.5 22.9 10.7 16.4 2.5 22.9 10.7 15.9 2.6 23.7 9.5 36 11 30 165 0.4 0 0.9 0.2 12/19/2006 08:50:00 17.3 2.5 22.9 11.5 17.2 2.5 23.3 11.1 16.5 2.4 24 10.7 34 10 38 165 0 0.3 0.7 -0.5 12/19/2006 09:00:00 16.8 2.1 22.1 11.1 16.5 2.2 22.1 11.1 16.3 2.2 21.4 10.7 27 11 35 165 -0.5 0 -0.3 -0.8 12/19/2006 09:10:00 17.8 2.6 22.9 9.9 17.6 2.7 23.3 9.5 17.1 2.6 22.9 10.7 27 10 26 165 -0.6 0 -0.3 -0.8 12/19/2006 09:20:00 18.8 2.8 24.4 11.1 18.5 2.9 24.8 11.1 18 2.8 24.8 9.9 23 10 36 165 -0.4 0 -0.3 -0.5 12/19/2006 09:30:00 17.5 2.2 23.3 11.8 16.8 2.6 22.6 9.9 16.7 2.4 22.1 11.5 18 8 24 165 -0.4 0.1 -0.1 -0.8 12/19/2006 09:40:00 15.8 2.4 21.4 9.9 14.1 2.8 20.6 7.2 15.4 2.2 21.4 9.9 12 9 10 165 -0.3 0 -0.1 -0.5 12/19/2006 09:50:00 16.2 2.3 21 10.7 13.8 2.7 20.2 8.4 15.7 2.3 20.6 9.9 11 8 360 165 -0.6 0 -0.3 -0.8 12/19/2006 10:00:00 17.1 2.1 21.4 12.2 14.5 2.7 21 8.8 16.8 2.4 22.1 11.1 11 9 15 165 -0.5 0 -0.3 -0.8 12/19/2006 10:10:00 17.6 1.7 22.6 13 13.6 2.1 19.1 9.1 17.4 1.8 22.6 11.8 7 8 7 165 -0.4 0 -0.3 -0.5 12/19/2006 10:20:00 15.6 2 21.8 11.5 12 2.2 18.7 7.2 15.7 2.2 22.6 12.2 3 9 14 165 -0.5 0 -0.3 -0.8 12/19/2006 10:30:00 15.5 3.1 26 10.3 11.8 3.1 22.6 6.8 15.3 3.1 27.1 9.5 2 9 8 165 -0.5 0 -0.3 -0.8 12/19/2006 10:40:00 15.7 2.6 23.3 11.1 12.8 3.5 22.6 7.6 15.8 2.4 23.7 10.7 7 9 356 165 -0.5 0 -0.3 -0.8 12/19/2006 10:50:00 15.2 2.2 23.7 10.7 12 2.5 18.7 8 14.9 2.2 24 9.5 357 9 4 165 -0.4 0 -0.3 -0.8 12/19/2006 11:00:00 16.1 2.4 22.9 9.9 12.8 2.6 19.9 8 16 2.5 22.6 10.3 357 9 3 165 -0.6 0 -0.5 -0.8 12/19/2006 11:10:00 17.2 2.9 25.6 11.8 13.2 2.9 21.8 8 16.9 3.1 25.2 11.5 358 10 11 165 -0.6 0 -0.5 -0.8 12/19/2006 11:20:00 16.9 2.3 22.6 11.1 13.1 2.5 22.1 7.6 17.2 2.6 23.7 9.5 359 9 355 165 -0.7 0 -0.5 -0.8 12/19/2006 11:30:00 18.5 2.7 28.3 12.2 15 3.2 25.6 9.1 18.4 2.7 29.1 12.6 355 10 355 165 -0.8 0 -0.5 -1 12/19/2006 11:40:00 18.9 2.5 26.3 13.3 14.7 3.2 27.5 9.1 18.9 2.7 27.9 13 356 9 345 165 -0.9 0 -0.8 -1.2 12/19/2006 11:50:00 18.5 3.1 28.7 11.5 16.7 3.2 24.8 9.1 18.7 3.5 27.1 8.4 349 13 3 165 -1.2 0.2 -0.8 -1.4 12/19/2006 12:00:00 20 2.8 29.4 13.3 17.5 3.2 28.3 11.1 20.1 3.1 30.9 13 351 11 350 165 -1.6 0 -1.4 -1.9 12/19/2006 12:10:00 18.7 3.8 29.4 9.9 15.7 3.3 26.3 8.8 19.2 4 30.2 11.1 352 13 355 165 -1.8 0 -1.7 -1.9 12/19/2006 12:20:00 19.7 3.2 27.5 13.3 16.9 3.2 25.6 9.9 19.8 3.5 30.2 12.6 354 15 355 165 -1.9 0 -1.7 -1.9 12/19/2006 12:30:00 16.9 2.9 28.7 11.8 16.3 2.9 27.9 11.1 16.6 3.1 27.5 10.3 331 15 330 165 -2 0 -1.7 -2.1 12/19/2006 12:40:00 18.6 3.2 28.3 11.5 18.3 3.3 27.9 10.3 17.9 3.3 27.5 9.9 332 15 326 165 -2.1 0 -1.9 -2.1 12/19/2006 12:50:00 20.7 2.6 30.9 13.7 20.6 2.5 31.3 14.1 20.1 2.6 28.7 13.3 326 12 344 165 -2.1 0 -1.9 -2.4 12/19/2006 13:00:00 20.3 3.8 31.8 11.8 20.2 4 31.3 10.3 19.6 4 30.6 9.5 326 12 329 165 -2.1 0 -1.9 -2.1 12/19/2006 13:10:00 20.8 3.8 30.6 13.3 20.7 3.6 30.6 13 20.1 4 30.6 11.1 323 12 329 165 -2 0 -1.9 -2.1 12/19/2006 13:20:00 21.8 3.3 30.9 13 21.7 3.2 31.3 11.8 21.2 3.6 30.2 11.8 326 10 329 165 -2 0 -1.7 -2.1 12/19/2006 13:30:00 23.4 3.8 34 11.8 23.2 3.8 32.9 11.8 23.2 4 34 7.6 330 12 326 165 -2 0 -1.9 -2.1 12/19/2006 13:40:00 25.2 3.2 33.6 18.3 25 3.2 32.9 15.3 24.9 3.1 32.9 17.2 329 9 329 165 -2 0 -1.9 -2.1 12/19/2006 13:50:00 24.7 4 36.3 13 24.4 4 34.4 12.6 24 4.3 35.2 13.3 329 11 322 165 -2.1 0 -1.9 -2.1 12/19/2006 14:00:00 27.6 4 36.3 14.9 27.4 4 35.9 14.9 27.2 4 37.1 14.9 332 10 339 165 -2.1 0 -1.9 -2.4 12/19/2006 14:10:00 29.4 3.5 38.2 16.8 29.2 3.5 37.5 16.1 29.1 3.5 39 16.1 329 8 326 165 -2.2 0 -2.1 -2.4 12/19/2006 14:20:00 27.9 4 39.4 16.4 27.8 4 39 16.4 27.6 4.1 38.2 16.4 331 10 313 165 -2.2 0 -1.9 -2.4 12/19/2006 14:30:00 27.4 4 40.5 13.7 27.2 4 40.1 14.5 26.9 4.1 39.4 11.1 329 11 313 165 -2.3 0 -1.9 -2.6 12/19/2006 14:40:00 24.4 3.5 33.2 15.3 24.4 3.5 32.9 12.6 24 3.6 33.6 14.9 330 9 339 165 -2.1 0 -1.9 -2.4 12/19/2006 14:50:00 25.5 4 36.7 16.8 25.5 4 36.7 13 25.4 4 37.1 14.9 329 10 323 165 -2.3 0.1 -2.1 -2.6 12/19/2006 15:00:00 25.1 3.2 34.8 16.8 25.1 3.3 34.4 16.4 24.9 3.3 34.4 15.6 330 10 327 165 -2.4 0 -2.1 -2.6 12/19/2006 15:10:00 25.2 4 38.2 15.6 25.2 4 38.2 15.6 25.2 4.1 37.1 14.9 329 12 317 165 -2.4 0 -2.1 -2.6 12/19/2006 15:20:00 26.3 3.8 35.9 16.1 26.3 4 36.3 12.6 26.1 4 36.3 16.8 332 9 328 165 -2.4 0 -2.1 -2.6 12/19/2006 15:30:00 22.8 2.9 30.2 12.6 22.9 3.2 30.2 12.2 22.6 3.1 31.3 12.6 329 12 313 165 -2.5 0 -2.4 -2.6 12/19/2006 15:40:00 25.2 3.5 34.8 16.1 25.2 3.6 35.2 15.6 24.8 3.3 33.6 16.8 334 10 327 165 -2.5 0 -2.1 -2.6 12/19/2006 15:50:00 24.4 3.3 32.4 14.1 23.9 3.8 33.6 14.1 24.2 3.3 33.6 14.5 336 13 315 165 -2.5 0 -2.4 -2.6 12/19/2006 16:00:00 25.1 3.3 33.6 14.9 25.1 3.5 33.6 14.9 24.5 3.2 32.4 15.3 335 8 322 165 -2.5 0 -2.4 -2.8 12/19/2006 16:10:00 23.9 3.8 31.8 12.6 24 4 32.1 13.7 23.2 3.8 31.3 13.7 335 8 350 165 -2.6 0 -2.6 -2.8 12/19/2006 16:20:00 22.9 3.1 34.8 14.5 23 3.1 33.2 14.5 22.3 3.2 32.1 12.2 332 11 354 165 -2.6 0 -2.6 -2.8 12/19/2006 16:30:00 23.4 3.1 30.9 14.5 23.4 3.2 30.9 14.1 22.7 3.5 32.9 15.6 333 10 339 165 -2.6 0 -2.6 -2.8 12/19/2006 16:40:00 24.3 3.3 33.2 16.1 24.4 3.3 32.9 16.1 23.9 3.5 32.9 16.4 337 8 349 165 -2.5 0 -2.4 -2.6 12/19/2006 16:50:00 22.5 3.3 30.9 14.9 22.2 3.8 31.8 11.8 22 3.3 30.6 14.5 339 11 329 165 -2.4 0 -2.1 -2.6 12/19/2006 17:00:00 24.1 2.7 32.4 16.1 23.7 2.9 32.4 13.3 23 2.8 30.6 15.6 338 9 341 165 -2.4 0 -2.1 -2.6 12/19/2006 17:10:00 23.7 2.2 30.6 18.7 23.9 2.6 31.3 15.3 22.8 2.4 30.9 16.4 338 7 349 165 -2.4 0 -2.1 -2.6 12/19/2006 17:20:00 21.8 3.2 33.6 12.2 21.4 3.5 33.2 13 20.6 3.5 33.2 11.8 338 10 330 165 -2.4 0 -2.1 -2.6 12/19/2006 17:30:00 23.6 2.9 31.8 14.5 23.6 3.2 31.8 12.2 23.4 2.9 30.9 15.6 335 11 328 165 -2.4 0 -2.1 -2.6 12/19/2006 17:40:00 24.1 3.3 34 13.7 24.2 3.5 34.4 14.1 23.8 3.5 33.6 13.3 335 10 339 165 -2.3 0 -2.1 -2.6 12/19/2006 17:50:00 24.8 3.2 33.6 15.3 24.7 3.2 34.4 15.3 24.2 3.5 36.3 15.3 334 9 332 165 -2.2 0 -2.1 -2.4 12/19/2006 18:00:00 22.5 4.3 34 12.2 22.1 4.7 34.8 9.9 22.3 4.3 35.2 11.8 334 14 1 165 -2.1 0 -1.9 -2.4 12/19/2006 18:10:00 22.8 3.2 32.1 11.8 22.8 3.3 31.8 11.1 22.4 3.5 31.3 10.7 334 12 314 165 -2.2 0 -1.9 -2.4 12/19/2006 18:20:00 23.9 3.6 31.8 16.1 23.6 4.1 32.9 13.7 23.8 3.6 33.2 16.1 339 9 336 165 -2.2 0 -1.9 -2.4 12/19/2006 18:30:00 20.7 3.3 31.3 10.3 20.5 3.8 31.3 8.8 20.4 3.5 31.3 9.5 334 13 346 165 -2.2 0 -1.9 -2.4 12/19/2006 18:40:00 17.4 2.7 24.4 10.7 17.4 2.7 24.8 10.3 16.9 2.5 22.1 10.3 337 9 349 165 -2.4 0 -2.1 -2.6 12/19/2006 18:50:00 21.2 3.1 30.6 13.3 21.1 3.2 30.6 12.2 20.9 3.1 30.9 11.1 335 10 333 165 -2.3 0 -1.9 -2.6 12/19/2006 19:00:00 16.8 2.9 25.2 10.7 16.6 2.9 24 11.1 16.2 2.9 25.2 10.7 331 13 350 165 -2.3 0 -1.9 -2.6 12/19/2006 19:10:00 15.5 3.1 25.6 7.6 15.4 3.1 24.8 8 15.1 3.2 26.8 7.6 328 14 325 165 -2.2 0 -1.9 -2.6 12/19/2006 19:20:00 14.3 2 20.2 9.1 14.3 2.2 20.6 9.9 13.8 2.3 18.7 7.6 329 15 298 165 -2.4 0 -2.1 -2.6 12/19/2006 19:30:00 16.1 2.5 25.6 8.8 16 2.4 25.6 9.5 15.1 2 21.8 9.1 313 12 299 165 -2.3 0 -2.1 -2.6 12/19/2006 19:40:00 17.7 2.4 24 11.1 17.6 2.3 22.9 11.1 16.6 2.4 23.3 10.3 313 15 305 165 -2.2 0 -2.1 -2.6 12/19/2006 19:50:00 16.1 2.2 22.9 10.7 16.1 2.2 23.3 10.7 15.1 2.2 21.8 9.1 316 13 313 165 -2.4 0 -2.1 -2.6 12/19/2006 20:00:00 16.5 2.5 27.5 11.1 16.6 2.5 27.5 11.1 15.6 2.5 27.1 10.3 318 10 319 165 -2.4 0 -2.1 -2.6 12/19/2006 20:10:00 17.2 2.8 24 6.5 17 2.9 23.7 6.5 16.6 2.6 24.8 9.5 327 15 309 165 -2.5 0 -2.1 -2.6 12/19/2006 20:20:00 16 1.8 22.9 10.7 15.9 1.9 23.3 10.7 15.1 2 22.1 9.9 325 14 322 165 -2.5 0.1 -2.1 -2.6 12/19/2006 20:30:00 16.5 1.7 21.4 11.5 16.3 1.6 21.4 11.5 15.7 1.9 21.4 11.5 321 15 334 165 -2.4 0 -2.1 -2.6 12/19/2006 20:40:00 17.7 2.8 26 11.8 17.5 2.7 24.8 11.5 17.3 2.7 25.2 10.7 331 13 346 165 -2.3 0 -2.1 -2.6 12/19/2006 20:50:00 18.7 2.9 27.1 13.3 18.5 2.8 26.3 12.6 18 2.8 26.3 12.2 321 16 348 165 -2.2 0 -1.9 -2.4 12/19/2006 21:00:00 17.8 2.6 26 11.5 17.7 2.7 26.3 11.8 17.4 2.6 25.2 11.5 329 13 341 165 -2.2 0 -1.9 -2.4 12/19/2006 21:10:00 17.4 2.4 26.3 8.8 17.3 2.4 26.8 8.8 16.9 2.4 25.6 10.3 326 12 300 165 -2.1 0 -1.9 -2.4 12/19/2006 21:20:00 18.1 2.5 24.4 11.8 18.1 2.5 24 12.2 17.3 2.6 24.4 11.1 321 15 312 165 -2.2 0 -1.9 -2.4 12/19/2006 21:30:00 18 2.3 23.3 11.1 17.9 2.2 23.3 11.8 17 2.1 23.3 11.1 317 15 313 165 -2.1 0 -1.9 -2.1 12/19/2006 21:40:00 18.6 2.7 27.5 13.7 18.5 2.6 28.3 13 17.9 2.6 27.5 11.5 319 15 304 165 -2.1 0 -1.9 -2.4 12/19/2006 21:50:00 19 2.6 25.2 12.2 18.9 2.6 25.2 12.2 18.3 2.7 25.6 11.8 318 12 320 165 -2.1 0 -1.7 -2.4 12/19/2006 22:00:00 19.3 2.4 28.3 13 19.1 2.4 28.3 13 18.5 2.2 26 13 320 13 301 165 -2 0 -1.9 -2.1 12/19/2006 22:10:00 17.4 1.7 22.1 13 17.4 1.7 22.1 12.6 16.3 2.1 22.1 11.5 318 13 320 165 -2 0 -1.9 -2.1 12/19/2006 22:20:00 19.5 2.3 25.6 14.5 19.4 2.4 25.2 14.1 18.8 2.6 25.6 13 320 12 315 165 -2 0 -1.7 -2.1 12/19/2006 22:30:00 19.5 2.3 25.6 14.5 19.4 2.2 26 13.7 18.2 2.3 24.8 12.2 313 9 315 165 -2 0 -1.7 -2.1 12/19/2006 22:40:00 21.1 2.1 28.7 16.1 20.9 2.2 28.7 16.1 20 2.4 28.3 14.1 312 8 309 165 -1.9 0.1 -1.4 -2.1 12/19/2006 22:50:00 20.7 2 26.8 14.9 20.6 2 26.3 14.9 19.9 2.2 26.8 12.2 317 9 312 165 -2 0 -1.7 -2.1 12/19/2006 23:00:00 20.6 2.3 26.3 15.6 20.4 2.3 26.8 15.6 19.6 2.3 24.4 13.7 317 9 316 165 -2 0.1 -1.7 -2.1 12/19/2006 23:10:00 19.6 1.8 25.6 15.3 19.5 1.8 25.2 14.9 18.7 1.8 24.4 14.9 315 9 301 165 -2 0 -1.9 -2.1 12/19/2006 23:20:00 20.5 2 27.1 15.3 20.3 2 26.8 15.3 19.8 2.2 26.8 15.3 315 7 309 165 -2.1 0 -1.9 -2.4 12/19/2006 23:30:00 21.9 2 27.9 16.1 21.7 2 27.5 15.6 20.5 2.2 26.3 15.6 310 8 314 165 -2.2 0 -1.9 -2.4 12/19/2006 23:40:00 21.2 2.3 27.1 15.3 21 2.2 27.1 15.6 20.7 2.3 26.3 14.9 317 9 312 165 -2.1 0 -1.9 -2.4 12/19/2006 23:50:00 20.2 2.4 26.3 13.7 20.1 2.4 27.5 13.7 19.2 2.4 26.8 12.6 314 10 316 165 -2.1 0 -1.9 -2.4 12/20/2006 00:00:00 20.4 2.2 28.3 14.5 20.2 2.2 28.3 14.5 19.2 2.4 27.5 14.5 313 9 287 165 -2 0 -1.9 -2.1 12/20/2006 00:10:00 21.2 1.7 25.6 17.2 21 1.7 26.8 17.2 20.4 1.9 27.9 16.1 315 7 315 165 -2.1 0 -1.9 -2.4 12/20/2006 00:20:00 21.8 2 27.9 17.2 21.6 2 27.5 17.2 20.9 2.2 29.4 14.9 317 7 314 165 -2 0 -1.9 -2.1 12/20/2006 00:30:00 22.1 2.1 27.5 16.4 21.9 2 27.5 16.8 20.9 2 27.9 15.6 313 6 315 165 -2 0 -1.9 -2.1 12/20/2006 00:40:00 21.2 2 25.6 16.4 21 2 25.2 16.1 20.3 2.2 25.2 14.5 316 7 313 165 -2.1 0 -1.9 -2.4 12/20/2006 00:50:00 20.4 1.7 24.4 15.3 20.2 1.7 24.4 15.6 19.5 2 24.4 14.1 318 8 310 165 -2.1 0 -1.9 -2.4 12/20/2006 01:00:00 20.3 2 24.8 14.5 20.1 1.9 24.8 14.1 19.7 2.2 24.4 14.5 320 8 319 165 -2.1 0 -1.9 -2.1 12/20/2006 01:10:00 21.3 1.7 25.2 15.6 21.1 1.7 25.2 14.9 20.8 1.9 26 13.7 318 7 310 165 -2.1 0 -1.9 -2.1 12/20/2006 01:20:00 20.2 1.9 24.8 12.6 20.1 1.8 24.8 12.6 20.1 2.1 24.4 13 318 5 317 165 -2 0 -1.9 -2.1 12/20/2006 01:30:00 20.3 1.9 26.3 15.3 20.1 1.9 25.6 15.3 19.8 2.1 24.4 13.3 318 6 307 165 -1.9 0 -1.7 -2.1 12/20/2006 01:40:00 21 2.2 26.3 15.3 20.8 2.2 26 14.9 20.5 2.3 25.6 14.1 319 6 321 165 -1.8 0 -1.7 -2.1 12/20/2006 01:50:00 22.1 1.9 26.3 16.4 21.9 1.9 26.3 16.4 21.8 2.1 26 16.1 320 5 313 165 -1.9 0.1 -1.7 -2.1 12/20/2006 02:00:00 21.3 1.8 25.2 15.3 21.1 1.8 25.2 15.6 20.9 1.9 24.8 15.3 318 6 318 165 -1.9 0 -1.7 -2.1 12/20/2006 02:10:00 21.2 1.6 26 16.1 21.1 1.6 25.6 15.6 20.6 1.7 25.6 14.9 317 7 310 165 -1.8 0 -1.7 -1.9 12/20/2006 02:20:00 21.3 1.5 25.2 17.2 21.2 1.5 26 17.2 20.5 1.7 24.4 16.4 315 5 309 165 -1.7 0 -1.4 -1.9 12/20/2006 02:30:00 18.8 1.9 24.8 14.1 18.7 1.9 24.4 14.5 18 2 25.2 13.3 315 7 315 165 -1.7 0 -1.4 -1.9 12/20/2006 02:40:00 18 1.8 23.3 13 18 1.8 24 13 17.3 1.7 22.1 12.2 314 6 316 165 -1.7 0 -1.4 -1.9 12/20/2006 02:50:00 14.8 1.4 18.7 10.7 14.7 1.4 19.1 10.3 13.9 1.5 18.3 10.3 316 7 313 165 -1.8 0 -1.4 -1.9 12/20/2006 03:00:00 15.6 1.5 19.9 11.1 15.5 1.5 19.9 11.1 14.2 1.5 17.6 10.3 313 6 312 165 -1.6 0 -1.4 -1.9 12/20/2006 03:10:00 15.4 1.5 19.1 12.2 15.4 1.5 19.1 12.2 14.4 2 20.2 9.5 312 7 319 165 -1.7 0.1 -1.4 -1.9 12/20/2006 03:20:00 15.7 1.5 19.1 11.8 15.7 1.5 19.5 11.8 13.4 1.8 17.9 9.1 306 8 303 165 -2.1 0 -1.9 -2.4 12/20/2006 03:30:00 14.7 1.5 18.3 11.5 14.7 1.5 18.7 11.1 13.3 1.9 18.3 8.8 310 7 307 165 -2.3 0 -2.1 -2.6 12/20/2006 03:40:00 15.8 1.1 18.3 12.2 15.7 1.1 17.9 11.8 14.3 1.4 17.6 8.8 309 5 314 165 -2.4 0 -2.1 -2.6 12/20/2006 03:50:00 13.2 1.4 18.3 10.3 13.2 1.5 17.9 10.3 11.8 1.7 17.9 7.2 307 8 304 165 -2.4 0 -2.1 -2.6 12/20/2006 04:00:00 12.2 1 14.5 9.5 12.2 1 14.5 9.5 9.9 1.2 13.3 6.8 301 9 307 165 -2.5 0 -2.1 -2.6 12/20/2006 04:10:00 14.1 1.6 18.7 8.8 14.1 1.6 18.7 9.1 12.9 2.1 17.6 8 307 9 306 165 -2.5 0 -2.4 -2.8 12/20/2006 04:20:00 15 1.5 18.7 11.1 15 1.5 18.7 11.5 14.4 1.7 18.7 9.5 311 6 312 165 -2.5 0 -2.1 -2.8 12/20/2006 04:30:00 13.2 2 17.9 8.8 13.2 2 17.9 8.8 12.3 2.2 17.6 6.5 309 6 319 165 -2.8 0 -2.6 -3 12/20/2006 04:40:00 9.3 1.2 13.3 6.8 9.3 1.1 13.3 6.5 8.7 1.3 12.2 6.1 310 9 316 165 -2.8 0 -2.6 -3 12/20/2006 04:50:00 10.8 1.5 13.3 6.5 10.8 1.5 13.7 6.5 10 1.7 13.3 5.7 311 6 316 165 -2.4 0.1 -2.1 -2.8 12/20/2006 05:00:00 8.4 1 11.5 6.1 8.4 1 11.1 6.5 7 0.9 9.9 4.6 305 7 303 165 -2.1 0 -1.9 -2.4 12/20/2006 05:10:00 8.6 0.9 11.5 6.1 8.6 0.9 11.5 6.5 6.7 0.9 9.5 4.6 295 8 292 165 -2 0 -1.7 -2.1 12/20/2006 05:20:00 7.1 1.1 9.9 4.2 7.1 1.1 9.9 4.6 5.9 1 8.8 2.6 305 8 293 165 -1.9 0.1 -1.7 -2.1 12/20/2006 05:30:00 5.2 1 7.2 3.4 5.3 1 7.2 3 4.4 0.8 6.5 2.6 304 11 302 165 -1.9 0 -1.7 -1.9 12/20/2006 05:40:00 4.8 1 7.6 2.6 4.8 1 8 2.6 4.1 0.7 6.1 2.3 306 9 289 165 -2 0 -1.7 -2.1 12/20/2006 05:50:00 6.4 0.8 8.4 4.2 6.4 0.8 8.8 4.6 5.4 0.9 8 3.4 290 7 286 165 -1.8 0 -1.7 -2.1 12/20/2006 06:00:00 6.5 0.7 8 4.9 6.6 0.7 8.4 5.3 5.6 1 8.4 3 290 6 298 165 -1.7 0 -1.4 -1.9 12/20/2006 06:10:00 5.8 1 8 3.4 5.9 1 8 3.8 5.5 0.9 7.6 3 283 7 288 165 -1.8 0 -1.7 -2.1 12/20/2006 06:20:00 7.8 1 10.3 4.9 7.9 1 10.3 4.9 7.3 1.3 10.3 3.8 286 5 290 165 -1.8 0 -1.4 -1.9 12/20/2006 06:30:00 9.5 0.8 11.1 6.5 9.7 0.8 11.1 6.8 9 1 11.1 5.7 285 4 283 165 -1.7 0 -1.4 -1.9 12/20/2006 06:40:00 9 0.6 10.3 7.2 9.2 0.6 10.3 7.2 8.5 0.8 10.3 5.3 287 3 288 165 -1.7 0 -1.4 -1.9 12/20/2006 06:50:00 8.3 0.5 9.9 6.8 8.4 0.4 9.5 6.8 8 0.6 9.9 6.1 285 3 283 165 -1.7 0 -1.4 -1.9 12/20/2006 07:00:00 6.2 1.1 9.1 3.4 6.9 0.6 9.1 5.7 6.7 0.6 8.4 5.3 272 6 277 165 -1.7 0 -1.4 -1.9 12/20/2006 07:10:00 5.2 0.6 7.2 3 5.9 0.5 7.6 4.9 5.7 0.5 7.2 4.6 258 3 264 165 -1.3 0 -1.2 -1.4 12/20/2006 07:20:00 5.3 0.6 6.5 3.8 5.9 0.3 6.8 5.3 5.7 0.3 6.5 4.9 268 5 270 165 -1.3 0 -1 -1.4 12/20/2006 07:30:00 5.1 0.4 5.7 4.2 5.3 0.4 6.1 4.2 5 0.3 5.7 4.2 274 5 278 165 -1.4 0 -1 -1.4 12/20/2006 07:40:00 3.7 0.5 4.9 2.6 4 0.4 4.9 3.4 3.8 0.4 4.9 3 264 6 270 165 -1.4 0 -1.2 -1.4 12/20/2006 07:50:00 3.4 0.4 4.6 2.6 3.5 0.4 4.6 2.6 3.4 0.3 4.2 2.6 228 17 241 165 -1.3 0 -1.2 -1.4 12/20/2006 08:00:00 3.3 0.4 4.2 2.3 3.2 0.5 4.2 1.9 3.2 0.5 4.6 2.3 182 23 205 165 -1.6 0.1 -1.2 -2.1 12/20/2006 08:10:00 3.3 0.5 4.6 1.9 3.3 0.6 4.6 1.9 3.3 0.6 4.6 1.5 207 17 191 165 -1.8 0 -1.4 -2.1 12/20/2006 08:20:00 2.6 0.5 3.4 1.1 2.6 0.5 3.4 1.1 2.5 0.5 3.4 1.5 258 19 233 165 -1.7 0 -1.4 -1.9 12/20/2006 08:30:00 1.6 0.5 3 0.4 1.7 0.5 3 0.7 1.7 0.5 2.6 0.7 251 13 235 165 -1.6 0 -1.4 -1.9 12/20/2006 08:40:00 2.5 0.3 3 1.9 2.5 0.3 3 1.9 2.5 0.3 3.4 1.9 236 6 234 165 -1.6 0 -1.2 -1.9 12/20/2006 08:50:00 2.7 0.5 3.8 1.5 2.7 0.5 3.8 1.5 2.6 0.5 3.8 1.5 235 6 244 165 -1.4 0 -1.2 -1.7 12/20/2006 09:00:00 3.2 0.6 5.3 1.5 3.3 0.6 5.7 1.5 3.1 0.6 4.9 1.5 246 13 276 165 -1.7 0 -1.4 -1.9 12/20/2006 09:10:00 4.7 0.9 6.5 2.3 5.5 0.8 7.2 3.4 5.1 0.7 6.8 3.4 260 8 256 165 -1.8 0.1 -1.4 -2.1 12/20/2006 09:20:00 5.6 0.9 7.6 3.4 7 0.6 8.4 4.9 6.3 0.7 7.6 4.2 262 4 255 165 -2 0 -1.7 -2.1 12/20/2006 09:30:00 5.6 0.9 7.2 3.4 7 0.6 8.4 5.3 6.5 0.7 8 4.6 266 6 252 165 -1.8 0 -1.7 -2.1 12/20/2006 09:40:00 5.6 0.7 7.2 3 5.9 0.7 7.6 3.8 5.4 0.7 7.2 3 276 5 277 165 -2 0 -1.7 -2.1 12/20/2006 09:50:00 4.1 0.8 6.5 2.6 5.1 0.5 6.5 3.8 4.7 0.6 6.5 3.4 266 3 273 165 -1.9 0 -1.4 -2.1 12/20/2006 10:00:00 4.2 0.8 5.3 2.3 5.1 0.4 5.7 4.2 4.8 0.4 5.7 3.8 266 3 265 165 -1.8 0 -1.4 -1.9 12/20/2006 10:10:00 4.2 0.5 4.9 2.6 4.6 0.3 5.3 4.2 4.5 0.3 5.3 3.8 261 11 265 165 -1.6 0 -1.4 -1.9 12/20/2006 10:20:00 3.3 0.6 4.6 2.3 3.3 0.6 4.9 2.3 3.3 0.7 4.9 2.3 219 9 236 165 -1.5 0 -1.2 -1.9 12/20/2006 10:30:00 2.4 0.5 3.4 1.1 2.3 0.5 3 0.7 2.4 0.4 3.4 1.5 185 22 168 165 -1.2 0 -1 -1.4 12/20/2006 10:40:00 1.8 0.3 2.6 1.1 1.6 0.3 2.6 1.1 1.9 0.3 2.6 1.1 171 5 184 165 -0.9 0.1 -0.5 -1.2 12/20/2006 10:50:00 1.5 0.5 2.3 0.4 1.2 0.5 2.3 0.4 1.6 0.5 2.6 0.7 168 3 164 165 -0.6 0.2 -0.1 -0.8 12/20/2006 11:00:00 0.8 0.3 1.5 0.4 0.5 0.3 1.5 0.4 0.9 0.3 1.5 0.4 173 5 173 165 0.1 0.2 0.7 -0.3 12/20/2006 11:10:00 1.9 0.4 2.3 0.7 1.4 0.4 2.3 0.4 1.8 0.4 2.6 0.7 169 5 165 165 0.4 0.2 0.9 -0.1 12/20/2006 11:20:00 1.9 0.4 3 1.1 1.4 0.4 2.6 0.7 1.9 0.3 2.3 1.1 195 16 189 165 0.4 0.3 1.1 -0.1 12/20/2006 11:30:00 1.4 0.3 2.3 0.7 0.9 0.3 1.9 0.4 1.3 0.4 2.3 0.4 271 45 334 165 1.2 0.2 1.8 0.9 12/20/2006 11:40:00 2.1 0.5 3 1.1 1.9 0.6 3 0.7 2 0.4 3 1.1 315 4 319 165 1.5 0.1 1.8 1.4 12/20/2006 11:50:00 3.4 0.3 4.2 2.3 3.4 0.3 4.2 2.3 3.2 0.4 4.2 1.9 314 3 321 165 0.7 0.2 1.4 -0.1 12/20/2006 12:00:00 2.9 0.5 4.2 1.9 2.9 0.6 4.2 1.9 2.7 0.5 3.8 1.5 319 6 312 165 0.4 0.2 0.9 -0.1 12/20/2006 12:10:00 0.9 0.6 2.3 0.4 1 0.6 2.3 0.4 1.2 0.5 2.3 0.4 32 64 321 165 0.5 0.4 1.1 -0.1 12/20/2006 12:20:00 1.5 0.5 2.3 0.4 1.5 0.5 2.6 0.4 1.3 0.4 2.3 0.4 303 33 305 165 0.5 0.2 1.1 -0.1 12/20/2006 12:30:00 1.1 0.5 2.6 0.4 1.1 0.5 2.6 0.4 0.8 0.5 2.3 0.4 293 10 309 165 -0.1 0.4 1.1 -0.5 12/20/2006 12:40:00 0.5 0.3 1.5 0.4 0.5 0.2 1.1 0.4 0.5 0.2 1.1 0.4 298 112 182 165 2 0.3 2.6 1.1 12/20/2006 12:50:00 0.9 0.4 1.9 0.4 0.9 0.4 1.9 0.4 0.9 0.5 1.9 0.4 162 13 173 165 1.5 0.2 1.8 1.1 12/20/2006 13:00:00 0.9 0.5 2.3 0.4 0.8 0.5 2.3 0.4 1 0.5 2.6 0.4 184 15 176 165 1.2 0.1 1.6 0.9 12/20/2006 13:10:00 1.7 0.3 2.6 0.7 1.7 0.4 2.6 1.1 1.8 0.3 2.6 1.1 215 8 218 165 0.4 0.4 1.4 -0.5 12/20/2006 13:20:00 0.8 0.5 1.9 0.4 0.8 0.5 1.9 0.4 1 0.5 1.9 0.4 238 4 242 165 -0.3 0.1 0.2 -0.5 12/20/2006 13:30:00 0.4 0 0.7 0.4 0.4 0 0.7 0.4 0.4 0.1 0.7 0.4 235 17 241 165 0.9 0.1 1.4 0.2 12/20/2006 13:40:00 0.8 0.4 1.9 0.4 0.8 0.4 1.9 0.4 0.9 0.4 1.9 0.4 120 18 114 165 0.6 0.2 1.4 0.2 12/20/2006 13:50:00 1.4 0.3 2.3 0.7 1.5 0.3 2.3 0.7 1.4 0.4 1.9 0.4 95 12 82 165 0 0.2 0.7 -0.3 12/20/2006 14:00:00 1.8 0.4 2.6 0.4 1.8 0.4 2.6 0.7 1.9 0.4 2.6 0.4 65 9 57 165 -0.9 0.3 0.2 -1.2 12/20/2006 14:10:00 1.5 0.7 2.6 0.4 1.5 0.7 2.6 0.4 1.6 0.7 2.6 0.4 56 8 57 165 -1.2 0.1 -0.8 -1.4 12/20/2006 14:20:00 2.9 0.4 3.8 1.9 2.9 0.4 3.8 1.9 3 0.4 3.8 1.9 54 6 68 165 -1.8 0.4 -1.2 -2.6 12/20/2006 14:30:00 2.8 0.5 3.8 1.5 2.9 0.5 3.8 1.9 2.9 0.4 3.8 1.9 87 11 75 165 -2.2 0.1 -1.9 -2.6 12/20/2006 14:40:00 2.3 0.4 3.4 1.1 2.3 0.5 3.4 1.1 2.3 0.5 3.4 0.7 95 11 95 165 -1.6 0.1 -1.2 -1.9 12/20/2006 14:50:00 2.7 0.3 3.4 2.3 2.8 0.3 3.4 2.3 2.8 0.3 3.4 2.3 62 11 54 165 -2.2 0.3 -1.7 -2.8 12/20/2006 15:00:00 3.7 0.3 4.2 3 3.8 0.2 4.2 3.4 3.8 0.3 4.6 3.4 56 3 52 165 -3 0.1 -2.6 -3.3 12/20/2006 15:10:00 3.7 0.4 4.2 3 3.8 0.4 4.6 3 3.9 0.4 4.6 3 43 7 54 165 -2.9 0 -2.6 -3 12/20/2006 15:20:00 2.9 0.2 3.4 2.6 3 0.2 3.4 2.6 2.9 0.2 3.4 2.3 42 5 37 165 -3.1 0.1 -2.6 -3.3 12/20/2006 15:30:00 2.5 0.2 3 1.9 2.6 0.2 3 1.9 2.5 0.2 3 1.9 50 2 49 165 -3.2 0.1 -2.8 -3.5 12/20/2006 15:40:00 2.5 0.2 3 1.9 2.5 0.2 3.4 2.3 2.5 0.2 3 2.3 54 4 52 165 -3.4 0.2 -2.8 -3.7 12/20/2006 15:50:00 2.4 0.3 3 1.9 2.5 0.3 3 1.9 2.4 0.3 3 1.9 50 7 50 165 -3.5 0 -3.3 -3.5 12/20/2006 16:00:00 2.4 0.2 3 1.9 2.5 0.2 3 1.9 2.5 0.2 3 1.9 61 11 76 165 -3.5 0 -3.3 -3.7 12/20/2006 16:10:00 2.3 0.2 2.6 1.9 2.4 0.2 3 1.9 2.4 0.2 3 1.9 75 10 81 165 -3.5 0 -3.3 -3.5 12/20/2006 16:20:00 2.4 0.4 3 1.5 2.4 0.4 3 1.5 2.3 0.4 3 1.5 47 1 48 165 -3.7 0 -3.3 -3.9 12/20/2006 16:30:00 1.5 0.3 2.3 1.1 1.4 0.4 2.3 0.4 1.5 0.3 2.3 1.1 24 15 46 165 -4.2 0.1 -3.7 -4.6 12/20/2006 16:40:00 1.6 0.3 2.3 0.7 1.3 0.3 1.9 0.7 1.6 0.3 2.3 0.7 8 5 4 165 -4.4 0 -4.2 -4.6 12/20/2006 16:50:00 1.6 0.3 2.3 1.1 1.5 0.4 2.3 0.4 1.7 0.2 2.3 1.1 353 7 351 165 -4.3 0 -4.2 -4.6 12/20/2006 17:00:00 1.6 0.3 2.3 1.1 1.3 0.4 2.3 0.4 1.7 0.3 2.3 1.1 4 7 353 165 -4.3 0 -4.2 -4.4 12/20/2006 17:10:00 1.9 0.3 2.6 1.1 2 0.4 3 0.7 1.9 0.3 2.6 1.5 343 4 348 165 -4.4 0 -4.2 -4.6 12/20/2006 17:20:00 2.6 0.3 3.4 1.9 2.6 0.3 3.4 1.9 2.6 0.3 3.4 1.9 334 11 338 165 -4.7 0.1 -4.4 -4.8 12/20/2006 17:30:00 2.4 0.4 3.4 1.5 2.4 0.4 3.4 1.1 2.4 0.4 3.4 1.1 329 12 314 165 -4.8 0 -4.6 -5 12/20/2006 17:40:00 2.4 0.3 3 1.9 2.4 0.3 3 1.9 2.2 0.4 3 1.5 335 4 341 165 -4.3 0.1 -3.9 -4.6 12/20/2006 17:50:00 2.5 0.3 3.4 1.9 2.5 0.3 3.4 1.9 2.3 0.4 3.4 1.1 313 7 316 165 -4.4 0 -4.2 -4.6 12/20/2006 18:00:00 3.1 0.6 5.3 2.3 3 0.6 5.7 1.1 3 0.5 5.3 2.3 328 13 340 165 -4.5 0 -4.4 -4.6 12/20/2006 18:10:00 4.8 0.7 6.1 3 4.7 0.8 6.8 3 4.7 0.7 6.1 3 343 7 348 165 -4.8 0 -4.6 -5 12/20/2006 18:20:00 5.8 0.6 7.2 4.2 5.2 1.1 7.2 2.3 5.8 0.6 7.2 4.2 349 7 349 165 -5.2 0.2 -4.6 -5.5 12/20/2006 18:30:00 5.1 0.6 6.5 3.8 5.1 0.6 6.8 3.4 5.1 0.6 6.5 3.8 339 7 339 165 -5.3 0 -5 -5.5 12/20/2006 18:40:00 5.2 0.9 7.2 3.4 5.2 1 7.6 3 5.1 0.9 7.2 2.6 331 11 338 165 -5 0.1 -4.6 -5.3 12/20/2006 18:50:00 4 0.5 5.3 1.9 3.9 0.5 5.3 1.9 3.8 0.7 6.1 2.3 307 12 304 165 -4.8 0.1 -4.6 -5 12/20/2006 19:00:00 5.1 1.3 9.5 3 5.2 1.3 9.9 3 4.7 1.1 8.4 2.3 296 9 294 165 -4.6 0 -4.4 -4.8 12/20/2006 19:10:00 7.1 1 9.1 4.9 7.2 1 9.1 4.6 5.8 0.8 9.1 3.8 301 6 304 165 -4.7 0 -4.4 -4.8 12/20/2006 19:20:00 5.2 1 8 3 5.3 0.9 7.6 3 4.6 0.8 6.8 2.6 304 9 298 165 -4.6 0 -4.4 -4.6 12/20/2006 19:30:00 4.7 0.7 6.5 3 4.5 0.8 6.8 2.6 4.5 0.7 6.5 3 330 16 346 165 -4.7 0 -4.6 -5 12/20/2006 19:40:00 4.9 0.7 7.2 3 4.9 0.8 8 2.6 4.9 0.7 6.8 3.4 336 10 349 165 -4.7 0 -4.4 -5 12/20/2006 19:50:00 4.5 0.8 6.8 2.6 4.5 0.8 6.5 2.3 4.6 0.7 6.8 3 333 11 326 165 -4.3 0 -3.9 -4.6 12/20/2006 20:00:00 4.9 0.7 6.5 3 4.9 0.8 6.5 3 4.3 0.8 6.1 1.9 312 11 322 165 -4.3 0 -4.2 -4.6 12/20/2006 20:10:00 5 0.8 7.2 3 5 0.8 7.2 3 4.3 0.9 7.2 2.3 303 9 294 165 -4.3 0 -3.9 -4.6 12/20/2006 20:20:00 6.6 0.7 8 4.2 6.6 0.6 8 4.6 5.5 0.7 7.6 4.2 303 10 302 165 -4.4 0.1 -4.2 -4.6 12/20/2006 20:30:00 6.9 0.8 8.8 3.8 6.9 0.8 8.8 3.8 5.5 0.8 8 3.4 303 8 308 165 -4.5 0 -4.4 -4.6 12/20/2006 20:40:00 6.7 0.8 8.4 4.6 6.7 0.8 8.4 4.6 6 0.8 8 3.8 311 13 293 165 -4.4 0 -4.2 -4.6 12/20/2006 20:50:00 6 0.8 8 4.6 6 0.8 8.4 4.6 5.6 0.9 7.6 3.4 328 12 337 165 -4.3 0.1 -3.9 -4.4 12/20/2006 21:00:00 7.2 1 9.5 4.9 7.2 1 9.9 4.6 6.8 1 9.9 4.2 334 11 347 165 -3.7 0.1 -3.5 -3.9 12/20/2006 21:10:00 6.1 0.8 8.4 4.2 6 1 8 2.6 5.8 0.8 8 3 335 12 336 165 -3.7 0 -3.5 -3.9 12/20/2006 21:20:00 6.6 1 9.5 4.2 6.4 1 9.1 3.8 6 1 8.8 3.8 325 9 331 165 -3.9 0 -3.5 -4.2 12/20/2006 21:30:00 7.3 0.8 9.1 4.2 7.2 0.8 9.1 4.2 6.4 0.8 8.4 4.2 309 8 307 165 -4.4 0.2 -3.9 -4.6 12/20/2006 21:40:00 6.5 0.8 8 4.2 6.4 0.8 8 4.2 5.3 0.8 7.2 3 308 7 310 165 -4.8 0 -4.6 -5 12/20/2006 21:50:00 5.7 0.8 7.6 2.6 5.6 0.8 7.6 3 4.8 0.9 7.2 2.6 314 11 307 165 -5 0 -4.8 -5 12/20/2006 22:00:00 4.5 1.1 6.8 2.3 4.4 1.1 6.8 1.9 4.1 1 6.1 1.1 317 13 308 165 -5 0 -4.6 -5.3 12/20/2006 22:10:00 4.6 1.5 8 1.1 4.6 1.5 8.4 1.1 4.1 1.3 8 1.1 309 14 309 165 -5 0 -4.8 -5.3 12/20/2006 22:20:00 6.4 1.1 9.1 3.4 6.4 1.1 8.8 3.4 5.4 1 8 2.6 302 9 307 165 -5.3 0 -5 -5.5 12/20/2006 22:30:00 7.3 1.1 9.5 4.6 7.3 1 9.5 4.6 5.8 0.8 8 3.8 299 7 300 165 -5.3 0 -5 -5.5 12/20/2006 22:40:00 6.7 0.6 8 4.9 6.7 0.6 8 4.9 5.9 0.6 7.6 4.2 310 6 309 165 -5.3 0 -5 -5.5 12/20/2006 22:50:00 7.8 1 10.3 5.3 7.8 1 10.3 5.7 6.2 0.8 9.5 4.2 302 7 308 165 -5.3 0 -5 -5.5 12/20/2006 23:00:00 9.4 0.8 12.6 7.6 9.5 0.8 11.8 7.6 7.6 1 12.6 5.7 297 8 310 165 -5.1 0 -4.8 -5.3 12/20/2006 23:10:00 10.1 1 14.5 7.6 10.1 1 14.5 7.6 8.4 1.3 13.3 5.3 294 7 300 165 -5.2 0.1 -5 -5.5 12/20/2006 23:20:00 10.1 1.1 12.6 7.6 10.2 1.1 12.6 7.6 8.6 1.4 12.6 5.7 292 8 294 165 -5.4 0 -5.3 -5.7 12/20/2006 23:30:00 10.4 0.8 12.6 8 10.5 0.8 12.6 8 8.7 1.3 12.2 5.7 294 7 295 165 -5.4 0 -5.3 -5.7 12/20/2006 23:40:00 10.6 0.8 13 8 10.6 0.9 13.3 8 8.2 1.2 12.6 5.7 295 7 301 165 -5.4 0 -5.3 -5.7 12/20/2006 23:50:00 10.9 0.9 12.6 8 10.9 0.9 12.6 8 8 1.1 11.8 5.7 296 7 302 165 -5.3 0 -5 -5.7 12/21/2006 00:00:00 11.2 1.2 14.9 8 11.2 1.2 14.5 7.6 8.3 1.1 11.1 5.3 294 8 298 165 -5.4 0 -5.3 -5.5 12/21/2006 00:10:00 11.5 1.1 14.5 8 11.5 1.1 14.5 8.4 8.6 1 11.8 6.5 298 8 299 165 -5.4 0 -5.3 -5.5 12/21/2006 00:20:00 12.6 1 14.9 9.9 12.5 1 14.9 9.1 9 1 11.5 6.5 297 8 307 165 -5.4 0 -5.3 -5.7 12/21/2006 00:30:00 12.6 0.9 14.5 9.9 12.6 0.9 14.1 9.9 8.6 0.8 12.2 6.5 299 7 302 165 -5.6 0 -5.5 -5.7 12/21/2006 00:40:00 12.1 0.8 13.7 9.5 12.1 0.8 13.3 9.5 8.7 1.1 12.6 6.1 296 7 297 165 -5.6 0 -5.5 -5.7 12/21/2006 00:50:00 12.3 0.9 14.5 9.1 12.3 1 14.5 8.8 8.8 0.9 11.8 6.5 300 7 301 165 -5.7 0 -5.5 -5.7 12/21/2006 01:00:00 12.1 1 13.7 9.1 12.1 1 14.1 9.1 8.4 0.8 10.7 6.5 299 6 304 165 -5.9 0 -5.7 -5.9 12/21/2006 01:10:00 12 0.7 13.3 9.1 12 0.7 13.3 9.1 8.3 0.7 10.7 6.5 298 6 294 165 -5.9 0 -5.7 -5.9 12/21/2006 01:20:00 11.6 0.6 13.3 9.5 11.6 0.6 13 9.9 8 0.6 9.9 6.1 300 6 302 165 -5.8 0 -5.5 -5.9 12/21/2006 01:30:00 10.5 0.6 12.6 9.1 10.6 0.6 12.2 8.8 7.4 0.8 10.7 5.7 298 6 299 165 -5.9 0 -5.7 -6.1 12/21/2006 01:40:00 9.3 0.6 11.1 8 9.4 0.6 11.1 8.4 6.6 0.7 9.5 4.9 301 3 292 165 -5.9 0 -5.7 -6.1 12/21/2006 01:50:00 7.9 1 10.3 4.9 7.9 1 10.3 4.9 6.7 1.1 9.5 3.4 306 9 313 165 -5.8 0 -5.5 -5.9 12/21/2006 02:00:00 9.8 1.5 13 6.1 9.7 1.5 13 6.1 7.9 1.5 11.5 4.6 303 9 303 165 -5.6 0 -5.5 -5.7 12/21/2006 02:10:00 11.3 1.1 13.7 8.4 11.2 1.1 13.7 8.8 9.8 1.2 13.3 6.1 308 8 304 165 -5.6 0 -5.5 -5.7 12/21/2006 02:20:00 10.8 1.2 13.7 7.2 10.6 1.2 13.3 7.2 9.8 1.3 12.6 5.3 314 7 309 165 -5.7 0.1 -5.5 -5.9 12/21/2006 02:30:00 8.8 0.8 10.7 6.5 8.7 0.9 10.7 6.5 6.9 1 9.5 4.9 301 10 293 165 -5.8 0 -5.5 -5.9 12/21/2006 02:40:00 8 0.7 9.9 6.1 7.9 0.7 9.5 5.7 7.2 0.9 9.9 4.9 312 9 319 165 -5.8 0.1 -5.5 -5.9 12/21/2006 02:50:00 8.5 0.7 10.3 6.8 8.5 0.7 10.3 6.8 6.5 0.8 8.8 4.2 300 7 301 165 -5.8 0 -5.7 -6.1 12/21/2006 03:00:00 8.3 0.7 10.3 6.1 8.3 0.7 10.7 6.1 6.9 1.2 10.7 4.6 291 7 287 165 -5.8 0 -5.5 -5.9 12/21/2006 03:10:00 9.2 0.6 10.7 7.2 9.2 0.6 11.1 7.2 7.6 1.2 10.7 4.9 291 7 282 165 -5.8 0 -5.5 -5.9 12/21/2006 03:20:00 9 0.7 11.1 6.1 9 0.7 11.1 6.5 6.8 1 9.9 4.6 296 7 301 165 -5.9 0 -5.7 -6.1 12/21/2006 03:30:00 8.6 0.7 10.7 6.8 8.6 0.7 11.1 6.5 6.5 1.2 10.7 4.2 297 6 286 165 -5.8 0.1 -5.5 -5.9 12/21/2006 03:40:00 9.2 1.1 11.8 6.1 9.2 1.2 11.8 6.1 6.9 1 10.3 4.6 299 7 300 165 -5.9 0 -5.7 -6.1 12/21/2006 03:50:00 9.5 0.9 12.2 7.2 9.5 0.9 12.2 7.2 7.2 1 9.9 4.9 296 8 306 165 -5.8 0 -5.7 -5.9 12/21/2006 04:00:00 10.9 1.1 13.7 7.6 10.9 1.1 13.3 7.6 8.7 1.4 13 6.1 304 7 291 165 -5.9 0 -5.7 -6.1 12/21/2006 04:10:00 10.7 1 14.1 8 10.7 1 14.1 8.4 8.2 1.3 13 6.1 299 9 288 165 -5.8 0.1 -5.5 -6.1 12/21/2006 04:20:00 10.7 1.1 13.3 8 10.7 1.1 13.3 8 8.4 1.6 13.7 5.7 295 9 287 165 -5.9 0 -5.5 -6.1 12/21/2006 04:30:00 10.5 0.9 13.3 8.8 10.5 0.9 13.7 8.8 7.8 1.1 11.5 5.7 296 9 289 165 -5.8 0.1 -5.5 -6.1 12/21/2006 04:40:00 10 1.2 13.3 7.2 10 1.2 13.3 7.2 8.1 1.5 11.8 4.6 291 10 292 165 -6 0 -5.7 -6.1 12/21/2006 04:50:00 9.9 1.2 13.7 6.5 9.9 1.3 13.7 6.5 8.5 1.7 12.6 5.3 291 10 286 165 -6 0 -5.7 -6.4 12/21/2006 05:00:00 9.7 1 12.6 6.8 9.7 1 12.2 6.8 7.7 1.2 11.1 4.9 292 9 291 165 -6.2 0.2 -5.7 -6.6 12/21/2006 05:10:00 10 1.1 13.3 7.6 10 1.2 13.3 7.2 7.8 1.1 12.2 5.3 296 10 295 165 -6.3 0.1 -6.1 -6.6 12/21/2006 05:20:00 10 1.3 14.9 6.8 9.9 1.3 14.5 6.8 7.9 1.3 13.3 4.9 297 12 284 165 -6.5 0 -6.1 -6.8 12/21/2006 05:30:00 10.3 1.5 14.1 6.5 10.2 1.4 14.1 6.8 8.2 1.5 13 5.3 294 12 305 165 -6.6 0 -6.4 -6.8 12/21/2006 05:40:00 10.2 1.4 14.5 6.5 10.3 1.4 14.9 6.5 9.1 1.5 14.9 5.7 286 10 257 165 -6.4 0 -6.1 -6.6 12/21/2006 05:50:00 8.3 0.8 10.3 6.5 8.4 0.8 10.7 6.1 7.4 1.1 10.3 4.9 286 8 280 165 -6.6 0 -6.4 -6.8 12/21/2006 06:00:00 8.6 1.1 11.5 6.5 8.7 1.1 11.8 6.5 7.7 1.1 11.5 4.9 287 7 286 165 -6.8 0 -6.6 -7 12/21/2006 06:10:00 10.8 1.7 14.9 7.2 10.7 1.7 15.3 7.2 8.8 1.8 13.3 4.9 299 13 300 165 -6.8 0 -6.6 -7 12/21/2006 06:20:00 13.2 1.4 16.4 9.9 13.1 1.5 16.8 9.5 10.3 1.3 14.9 7.2 297 11 296 165 -6.8 0 -6.6 -7 12/21/2006 06:30:00 14.6 1.3 17.6 10.7 14.5 1.3 17.6 11.1 11.6 1.7 16.4 8.4 294 12 305 165 -6.8 0 -6.6 -7 12/21/2006 06:40:00 13 1.7 17.2 8 13 1.7 17.2 8.4 10.5 1.7 16.1 6.8 291 11 288 165 -6.8 0.1 -6.6 -7 12/21/2006 06:50:00 11.1 1.1 14.1 8 11.2 1.2 14.1 8 9.6 1.7 13.3 5.7 286 9 283 165 -7 0 -6.8 -7.2 12/21/2006 07:00:00 12.3 1 14.9 9.1 12.3 1.1 15.3 9.5 11 1.7 15.3 6.8 285 7 276 165 -7.1 0.1 -6.8 -7.4 12/21/2006 07:10:00 11.5 1.7 14.9 8 11.6 1.8 15.3 7.6 10.9 2 15.3 6.5 283 6 285 165 -7.1 0 -6.8 -7.2 12/21/2006 07:20:00 10.3 1.3 13 6.8 10.4 1.3 13.3 7.2 9.6 1.5 13.3 6.1 282 8 278 165 -7.2 0 -6.8 -7.4 12/21/2006 07:30:00 11.4 1.5 15.3 6.8 11.4 1.5 15.3 7.2 10.3 1.7 14.5 6.1 283 8 265 165 -7.1 0.1 -6.8 -7.4 12/21/2006 07:40:00 10.5 1 13 8 10.5 1 13.3 8 9.4 1.5 13.3 6.1 284 7 286 165 -7.1 0 -6.8 -7.2 12/21/2006 07:50:00 9.9 1.1 13.7 6.5 10 1.2 13.7 6.5 8.5 1.5 13 5.3 287 8 284 165 -7.1 0 -6.8 -7.2 12/21/2006 08:00:00 10 1.3 12.6 5.7 9.9 1.3 12.6 5.7 8.4 1.5 12.2 3.8 286 9 278 165 -7.1 0 -6.8 -7.2 12/21/2006 08:10:00 7.5 1.4 11.5 4.9 7.5 1.5 11.8 4.9 6.2 1.4 10.3 3 296 11 282 165 -7.2 0.1 -6.8 -7.4 12/21/2006 08:20:00 10.7 1.2 13.7 7.6 10.7 1.2 13.3 7.6 8.6 1.4 12.2 4.6 294 12 284 165 -7.1 0.1 -6.8 -7.4 12/21/2006 08:30:00 11.3 1.1 14.1 8.4 11.3 1.1 14.1 8.4 8.8 1.4 13.3 6.1 291 10 278 165 -7.2 0 -6.8 -7.4 12/21/2006 08:40:00 12.3 1.4 15.3 8.8 12.3 1.4 15.3 8.4 9.9 1.8 15.6 6.1 290 9 287 165 -7.1 0.1 -6.8 -7.2 12/21/2006 08:50:00 10.4 1.3 13.3 6.8 10.5 1.3 13 6.8 8.1 1.6 12.6 4.9 293 11 291 165 -7 0 -6.8 -7.2 12/21/2006 09:00:00 9.1 1.3 12.6 6.1 9.1 1.3 12.6 6.1 7.4 1.3 11.1 4.2 291 10 294 165 -7.2 0.1 -6.8 -7.4 12/21/2006 09:10:00 8.2 1.2 11.1 5.3 8.3 1.2 11.1 5.3 6.8 1.2 11.1 3.8 291 8 274 165 -7.3 0 -7 -7.4 12/21/2006 09:20:00 9.9 1.7 13.7 6.5 9.9 1.6 14.1 6.1 8.2 1.7 12.6 4.2 288 10 287 165 -7.1 0.1 -6.8 -7.4 12/21/2006 09:30:00 7.4 2 12.6 3.8 7.4 1.9 12.6 4.2 6.3 2 14.1 2.6 290 12 287 165 -7 0 -6.6 -7.2 12/21/2006 09:40:00 7.7 1.1 10.7 5.3 8 1.2 10.7 5.3 7.4 1.3 11.1 4.6 281 9 276 165 -7.1 0 -6.8 -7.4 12/21/2006 09:50:00 7.4 0.8 9.9 5.3 7.5 0.9 9.5 5.3 6.9 1.2 10.3 4.2 285 8 282 165 -7.1 0 -6.8 -7.2 12/21/2006 10:00:00 4.7 1.4 8 1.9 4.8 1.4 8 2.3 4.5 1.2 7.2 2.3 261 24 287 165 -6.8 0 -6.6 -7.2 12/21/2006 10:10:00 3 0.8 4.6 0.7 3 0.8 4.6 1.1 2.9 0.9 4.6 0.4 255 30 290 165 -6.6 0.1 -6.1 -6.8 12/21/2006 10:20:00 3.9 0.7 5.7 1.9 4 0.7 6.1 2.3 3.9 0.7 5.7 2.3 255 38 274 165 -6.6 0.2 -6.1 -6.8 12/21/2006 10:30:00 2.8 0.6 4.2 1.5 2.8 0.5 4.6 1.5 2.7 0.5 3.8 1.5 253 22 279 165 -6.4 0 -6.1 -6.6 12/21/2006 10:40:00 3.9 0.6 5.3 2.3 4.2 0.5 5.3 3 3.9 0.5 5.3 2.6 272 5 276 165 -6.8 0.2 -6.4 -7 12/21/2006 10:50:00 4.9 0.4 6.1 3.8 4.9 0.4 6.1 3.8 4.8 0.4 6.1 3.8 280 4 280 165 -6.9 0 -6.8 -7.2 12/21/2006 11:00:00 5 0.5 6.5 4.2 5 0.5 6.5 3.8 4.5 0.6 6.1 3 281 4 280 165 -6.8 0 -6.6 -6.8 12/21/2006 11:10:00 4.2 0.5 5.3 2.6 4.5 0.5 5.7 3 4.1 0.5 5.3 3 276 8 284 165 -6.6 0 -6.4 -6.8 12/21/2006 11:20:00 4 0.4 4.9 2.6 4.1 0.4 4.9 3 3.4 0.6 4.9 1.9 289 6 280 165 -6.4 0.1 -6.1 -6.6 12/21/2006 11:30:00 4.3 0.6 6.1 3 4.4 0.6 6.1 3 3.3 0.9 5.7 1.9 292 8 283 165 -6.2 0.1 -5.9 -6.6 12/21/2006 11:40:00 4.9 0.4 6.1 3.8 5 0.4 6.5 3.8 4.1 0.6 5.7 2.6 289 7 286 165 -6.4 0 -5.7 -6.6 12/21/2006 11:50:00 5.5 0.5 6.8 4.2 5.6 0.6 6.8 4.2 4.3 0.7 6.5 3 294 6 289 165 -6.3 0 -6.1 -6.6 12/21/2006 12:00:00 6.3 0.4 7.2 5.3 6.3 0.4 7.6 5.3 4.9 0.7 7.2 3.4 293 6 290 165 -6.3 0 -6.1 -6.6 12/21/2006 12:10:00 6 0.7 7.6 4.2 6.1 0.7 8 4.6 5.2 0.8 7.6 3 287 8 291 165 -6.2 0 -5.9 -6.4 12/21/2006 12:20:00 5.7 0.6 7.2 3.8 5.9 0.6 7.2 4.2 5.4 0.7 7.2 3.4 277 7 270 165 -6 0 -5.7 -6.1 12/21/2006 12:30:00 6.8 0.6 8 4.9 6.8 0.6 8 4.6 5.2 0.7 7.2 3.4 293 6 298 165 -6 0 -5.7 -6.1 12/21/2006 12:40:00 6.4 1.3 9.5 4.2 6.4 1.3 9.1 4.2 4.7 1.1 8.8 2.6 294 6 288 165 -5.9 0.1 -5.5 -6.1 12/21/2006 12:50:00 2.9 0.8 4.9 0.7 3 0.8 4.9 1.1 2.6 0.8 4.9 1.1 256 22 285 165 -5.3 0.3 -4.4 -5.7 12/21/2006 13:00:00 2.4 0.5 3.8 1.1 2.4 0.5 3.8 1.5 2.2 0.4 3.4 1.5 244 9 248 165 -4.6 0.1 -4.4 -4.8 12/21/2006 13:10:00 0.6 0.4 1.9 0.4 0.6 0.4 1.9 0.4 0.5 0.4 1.9 0.4 182 22 228 165 -3.3 0.9 -1.9 -4.8 12/21/2006 13:20:00 2 0.7 3.4 0.4 1.8 0.7 3.4 0.4 2 0.7 3.8 0.4 177 13 179 165 -3.1 0.6 -1.9 -3.9 12/21/2006 13:30:00 3.3 0.4 4.6 2.3 3.2 0.4 4.9 1.9 3.4 0.5 4.6 1.9 178 5 166 165 -4.4 0.1 -3.9 -5 12/21/2006 13:40:00 3.5 0.5 4.6 2.3 3.4 0.5 4.6 2.3 3.6 0.5 4.6 1.9 179 8 183 165 -4.7 0.1 -4.4 -5 12/21/2006 13:50:00 3.1 0.4 4.2 1.9 3 0.4 4.2 1.9 3.2 0.5 4.9 1.9 177 9 182 165 -4.7 0.1 -4.4 -5.3 12/21/2006 14:00:00 2.1 0.5 3 0.7 2.1 0.5 3 0.7 2.3 0.4 3.4 1.1 176 9 164 165 -4.4 0.1 -4.2 -4.8 12/21/2006 14:10:00 3.2 0.6 4.2 1.9 3.1 0.6 4.2 1.9 3.3 0.6 4.6 1.5 195 5 191 165 -4.7 0.2 -4.4 -5 12/21/2006 14:20:00 1.8 0.4 3.4 1.1 1.9 0.4 3.4 1.1 1.9 0.4 2.6 1.1 201 7 210 165 -4.4 0.1 -4.2 -5 12/21/2006 14:30:00 3.1 0.5 4.6 1.9 3 0.4 4.2 1.9 3.2 0.5 4.2 1.9 185 7 187 165 -4.8 0.2 -4.2 -5.5 12/21/2006 14:40:00 3.9 0.4 4.9 3 3.9 0.4 4.9 2.6 3.8 0.4 4.9 2.3 193 8 192 165 -5.3 0.2 -5 -5.7 12/21/2006 14:50:00 3.9 0.5 4.9 2.6 3.8 0.5 4.9 2.6 3.9 0.5 4.9 3 197 5 196 165 -5.5 0.1 -5.3 -6.1 12/21/2006 15:00:00 4.5 0.6 6.1 3.4 4.6 0.6 5.7 3.4 4.6 0.6 6.1 3.4 200 5 194 165 -5.7 0.1 -5.5 -6.4 12/21/2006 15:10:00 5.2 0.2 6.1 4.6 5.3 0.2 5.7 4.6 5.5 0.3 6.1 4.2 200 5 206 165 -5.9 0 -5.7 -6.4 12/21/2006 15:20:00 4 0.6 5.3 2.3 4.1 0.7 5.3 2.3 3.8 0.8 5.3 1.5 220 7 215 165 -5.8 0.1 -5.5 -6.1 12/21/2006 15:30:00 3.3 0.6 4.9 1.9 3.2 0.6 4.6 1.9 3 0.6 4.6 1.9 203 13 226 165 -5.6 0 -5.5 -5.7 12/21/2006 15:40:00 4 0.6 5.7 2.6 3.9 0.6 5.7 2.3 3.9 0.6 5.3 2.3 179 6 176 165 -6 0.1 -5.5 -6.6 12/21/2006 15:50:00 5.2 0.4 6.5 3.8 5 0.5 6.1 3.8 5.2 0.4 6.1 4.2 189 6 197 165 -6.5 0.1 -6.1 -6.8 12/21/2006 16:00:00 4.7 0.3 5.7 3.8 4.4 0.3 5.3 3.8 4.6 0.3 5.3 4.2 180 3 192 165 -6.7 0 -6.6 -6.8 12/21/2006 16:10:00 5.1 0.3 6.1 4.2 5.1 0.3 6.1 4.2 4.9 0.4 5.7 3.8 197 8 217 165 -6.7 0 -6.6 -6.8 12/21/2006 16:20:00 6.5 0.5 7.6 5.3 6.6 0.5 7.2 5.3 6.6 0.6 7.6 4.9 199 3 201 165 -6.8 0 -6.6 -7 12/21/2006 16:30:00 5.3 0.6 6.5 4.2 5.3 0.6 6.5 4.2 5.4 0.6 6.8 3.8 196 4 191 165 -6.7 0 -6.6 -6.8 12/21/2006 16:40:00 4.5 0.3 5.3 3.4 4.6 0.3 5.3 3.4 4.6 0.5 5.7 3 199 3 198 165 -6.6 0 -6.4 -6.8 12/21/2006 16:50:00 3.7 0.3 4.6 3 3.8 0.3 4.6 3 3.8 0.3 4.6 3 210 8 213 165 -6.7 0.1 -6.6 -7 12/21/2006 17:00:00 3.4 0.5 4.2 2.3 3.4 0.5 4.6 2.3 3.6 0.5 4.6 2.3 214 9 221 165 -6.9 0 -6.8 -7 12/21/2006 17:10:00 2.9 0.4 3.8 1.9 2.9 0.3 3.4 2.3 3.1 0.3 3.8 2.3 190 7 187 165 -6.8 0 -6.6 -7 12/21/2006 17:20:00 2.9 0.5 4.6 1.9 2.9 0.5 4.6 1.9 2.9 0.5 4.2 1.9 197 6 199 165 -6.7 0 -6.6 -6.8 12/21/2006 17:30:00 4.2 1 6.5 2.3 4.3 1 6.5 2.3 4 1 6.1 1.9 213 6 207 165 -6.5 0 -6.1 -6.8 12/21/2006 17:40:00 5.3 0.8 7.2 3.4 5.3 0.8 7.2 3.4 5.1 0.8 6.8 3.4 204 6 201 165 -6 0.1 -5.7 -6.6 12/21/2006 17:50:00 4.2 0.5 5.7 3.4 4.2 0.5 5.3 3 4.1 0.6 5.3 2.6 196 5 193 165 -6.1 0.1 -5.7 -6.4 12/21/2006 18:00:00 4.9 0.3 5.7 4.2 4.8 0.3 5.3 4.2 5 0.4 6.1 3.8 191 5 192 165 -6.1 0 -5.7 -6.4 12/21/2006 18:10:00 4.7 0.4 5.7 3.8 4.5 0.3 5.3 3.8 4.4 0.4 5.3 3.4 184 4 183 165 -6.1 0 -5.9 -6.4 12/21/2006 18:20:00 3.7 0.4 4.6 3 3.6 0.4 4.6 3 3.4 0.4 4.6 2.6 187 4 189 165 -6.2 0 -6.1 -6.4 12/21/2006 18:30:00 3.8 0.4 4.6 3 3.7 0.3 4.6 3 3.7 0.5 4.6 2.6 184 4 182 165 -6.2 0 -5.9 -6.4 12/21/2006 18:40:00 3.8 0.4 4.6 3 3.6 0.4 4.2 3 3.8 0.6 4.9 2.6 178 6 174 165 -6 0.1 -5.7 -6.4 12/21/2006 18:50:00 5.1 0.6 6.5 4.2 4.8 0.5 6.1 3.8 5 0.4 6.1 3.8 172 8 181 165 -5.9 0 -5.7 -6.1 12/21/2006 19:00:00 4.9 0.3 5.7 4.2 4.7 0.2 5.3 4.2 4.7 0.3 5.3 3.8 175 6 179 165 -5.9 0 -5.5 -6.1 12/21/2006 19:10:00 5.8 0.5 7.2 4.6 5.5 0.5 6.8 4.6 5.5 0.4 6.5 4.6 172 4 165 165 -5.9 0 -5.7 -6.1 12/21/2006 19:20:00 6.4 0.4 7.2 4.9 6.1 0.4 6.8 4.9 6.1 0.5 6.8 4.6 167 6 172 165 -5.9 0 -5.7 -6.1 12/21/2006 19:30:00 6.4 0.4 7.2 5.3 6.1 0.4 7.2 5.3 6.2 0.4 7.2 5.3 173 4 175 165 -5.4 0.2 -5 -6.1 12/21/2006 19:40:00 7 0.5 8 5.7 6.7 0.5 7.6 5.7 6.6 0.6 8 5.3 177 3 172 165 -5 0.1 -4.6 -5.5 12/21/2006 19:50:00 6.5 0.7 7.6 4.6 6.2 0.7 7.6 4.6 6.3 0.8 7.6 4.6 176 4 176 165 -4.9 0 -4.6 -5 12/21/2006 20:00:00 5.4 0.9 6.8 3.4 5.3 0.8 6.8 3.8 5.1 1 7.2 3 168 13 173 165 -5 0 -4.8 -5.5 12/21/2006 20:10:00 5.4 0.6 6.1 3.4 5.2 0.5 6.1 3.4 5.1 0.6 6.1 3.4 171 9 173 165 -4.9 0.2 -4.6 -5.5 12/21/2006 20:20:00 4.8 0.5 6.1 3.8 4.6 0.5 5.7 3.4 4.7 0.6 6.1 3 171 6 176 165 -5 0 -4.6 -5.3 12/21/2006 20:30:00 4.4 0.2 4.9 3.8 4.2 0.2 4.6 3.8 4.5 0.2 4.9 3.8 177 3 173 165 -4.8 0 -4.6 -5 12/21/2006 20:40:00 4.2 0.3 4.6 3.4 4 0.3 4.6 3.4 4.2 0.2 4.9 3.4 175 4 183 165 -4.7 0 -4.4 -4.8 12/21/2006 20:50:00 3.5 0.2 3.8 2.6 3.3 0.2 3.8 2.6 3.4 0.3 3.8 2.6 168 5 169 165 -4.7 0 -4.4 -4.8 12/21/2006 21:00:00 3.6 0.3 4.2 3 3.4 0.3 4.2 3 3.4 0.3 4.2 2.6 163 10 171 165 -4.7 0 -4.4 -4.8 12/21/2006 21:10:00 4.6 0.8 6.5 3.4 4.3 0.7 6.1 3 4.1 0.7 5.7 2.6 156 9 148 165 -4.7 0 -4.4 -4.8 12/21/2006 21:20:00 5.7 0.5 6.8 4.9 5.5 0.5 6.5 4.6 5.6 0.5 6.5 4.6 158 8 162 165 -3.9 0.2 -3.5 -4.6 12/21/2006 21:30:00 3.7 1.2 5.7 1.5 3.6 1.2 5.7 1.1 3.7 1.2 5.7 1.5 147 13 159 165 -3.9 0.1 -3.5 -4.4 12/21/2006 21:40:00 2.3 0.5 3.4 1.1 2.2 0.6 3.4 0.7 2.4 0.4 3.4 1.1 138 11 139 165 -4.2 0 -3.9 -4.4 12/21/2006 21:50:00 3.3 0.5 4.6 2.3 3.3 0.4 4.2 2.3 3.2 0.5 4.6 2.3 142 10 160 165 -3.9 0 -3.7 -4.2 12/21/2006 22:00:00 3.7 0.6 4.9 1.9 3.6 0.6 4.9 1.9 3.4 0.6 4.9 1.9 153 9 158 165 -3.6 0.1 -3.3 -3.9 12/21/2006 22:10:00 3.3 0.5 4.6 2.3 3.2 0.5 4.6 1.9 3.2 0.5 4.2 1.9 153 7 164 165 -3.6 0 -3.3 -3.7 12/21/2006 22:20:00 3.4 0.5 4.6 2.3 3.4 0.5 4.2 2.3 3.4 0.4 4.2 2.3 153 5 146 165 -3.5 0 -3.3 -3.5 12/21/2006 22:30:00 3.5 0.4 4.2 2.6 3.5 0.4 4.2 2.6 3.4 0.4 4.2 2.6 141 5 152 165 -3.5 0 -3.3 -3.7 12/21/2006 22:40:00 3.6 0.6 5.3 1.9 3.6 0.6 5.3 2.3 3.4 0.6 5.3 1.9 139 7 143 165 -3.5 0 -3.3 -3.5 12/21/2006 22:50:00 3.5 0.5 4.6 2.3 3.6 0.5 4.6 2.3 3.5 0.4 4.6 2.3 133 8 130 165 -3.2 0 -3 -3.5 12/21/2006 23:00:00 3.7 0.6 5.3 2.3 3.7 0.6 4.9 1.9 3.7 0.6 5.3 2.3 133 9 119 165 -3.3 0 -2.8 -3.5 12/21/2006 23:10:00 4.6 0.6 6.1 3 4.6 0.6 6.1 3.4 4.5 0.6 6.1 3 124 7 133 165 -3.1 0 -2.8 -3.3 12/21/2006 23:20:00 5.2 0.4 6.1 4.2 5.3 0.4 6.1 4.2 5.2 0.4 6.1 4.2 118 3 119 165 -2.9 0 -2.6 -3.3 12/21/2006 23:30:00 5 0.4 5.7 4.2 5.1 0.4 6.1 4.6 5 0.4 5.7 4.2 110 6 119 165 -2.8 0 -2.6 -3 12/21/2006 23:40:00 5.2 0.6 7.2 3.8 5.4 0.6 7.2 4.2 5.1 0.6 6.8 3.8 97 6 100 165 -2.8 0 -2.6 -2.8 12/21/2006 23:50:00 5 0.7 6.8 3.4 5.2 0.7 6.8 3.4 5.1 0.7 6.8 3 95 6 96 165 -3 0.1 -2.6 -3.3 12/22/2006 00:00:00 6.3 0.5 7.6 5.3 6.5 0.5 8 4.9 6.1 0.5 7.2 4.6 104 5 102 165 -2.6 0 -2.6 -2.8 12/22/2006 00:10:00 6.4 0.6 7.6 4.2 6.5 0.6 7.6 4.6 6 0.7 8.4 4.2 93 8 91 165 -2.8 0.1 -2.6 -3 12/22/2006 00:20:00 5.5 0.9 7.6 3.4 5.7 1 8 3.4 5.2 0.9 7.6 3 78 11 84 165 -3.4 0.2 -2.8 -3.7 12/22/2006 00:30:00 7.1 0.6 8.8 5.7 7.3 0.6 9.1 5.7 6.9 0.7 8.4 4.6 95 6 87 165 -2.6 0.2 -2.4 -3 12/22/2006 00:40:00 5.9 0.8 8 3.4 6 0.9 8 3.8 5.6 0.8 7.2 3.4 85 8 102 165 -2.9 0.2 -2.4 -3.5 12/22/2006 00:50:00 6.3 1.3 9.5 3.4 6.4 1.3 9.5 3.4 5.9 1.2 8.4 3.4 79 12 85 165 -2.9 0.2 -2.4 -3.3 12/22/2006 01:00:00 6.9 1.2 9.5 3.8 7.1 1.2 9.5 3.8 6.6 1.1 9.1 3.4 79 11 94 165 -2.4 0.1 -2.1 -2.8 12/22/2006 01:10:00 5.7 1.1 7.6 3.8 5.8 1.2 8 3.8 5.4 1.1 8 3 68 10 63 165 -3 0 -2.6 -3.3 12/22/2006 01:20:00 8 1.1 10.7 5.3 8.2 1.1 11.1 5.3 7.7 1.1 11.1 5.3 76 6 81 165 -2.4 0.1 -1.9 -2.8 12/22/2006 01:30:00 6.6 1 9.1 4.2 6.7 1 9.5 4.6 6.4 1 9.1 4.2 69 7 83 165 -2.4 0 -1.9 -2.6 12/22/2006 01:40:00 6.8 1.1 9.5 4.2 7 1.1 9.5 4.6 6.4 1 9.5 4.2 68 9 71 165 -2.3 0 -2.1 -2.6 12/22/2006 01:50:00 8 1.3 10.3 4.9 8.1 1.3 10.7 5.3 7.7 1.2 10.7 4.9 64 7 63 165 -2.1 0.1 -1.7 -2.4 12/22/2006 02:00:00 7 1.1 10.3 4.9 7.2 1.1 11.1 5.3 6.7 1 9.9 4.6 60 7 58 165 -2.1 0 -1.9 -2.4 12/22/2006 02:10:00 7.7 1.1 11.1 4.9 7.8 1.2 11.5 4.9 7.3 1.1 10.7 4.6 54 7 41 165 -2 0 -1.9 -2.1 12/22/2006 02:20:00 8.1 1.4 11.5 4.6 8.2 1.4 11.1 4.6 7.8 1.4 11.1 4.2 45 8 39 165 -2 0 -1.9 -2.1 12/22/2006 02:30:00 8.1 1.3 11.8 4.9 8.1 1.3 12.2 4.6 7.7 1.3 11.5 4.6 43 8 49 165 -2 0 -1.7 -2.1 12/22/2006 02:40:00 8.6 1.1 11.8 4.9 8.6 1.2 12.2 4.6 8.1 1.1 11.1 4.9 45 7 54 165 -1.7 0 -1.4 -1.9 12/22/2006 02:50:00 9.4 1.1 12.2 6.1 9.4 1.2 12.2 6.1 9.2 1.3 13.3 4.9 41 9 41 165 -1.6 0 -1.4 -1.9 12/22/2006 03:00:00 9.3 1.3 12.2 5.7 9.3 1.3 12.2 5.7 8.8 1.2 12.2 6.1 44 9 35 165 -1.5 0 -1.2 -1.9 12/22/2006 03:10:00 8.5 1.7 14.5 4.2 8.6 1.8 14.9 4.2 8.3 1.7 13.3 5.3 56 14 78 165 -1.7 0 -1.4 -1.9 12/22/2006 03:20:00 10.5 2.1 15.6 6.1 10.6 2.1 16.1 6.1 10.2 2.1 14.9 5.3 49 10 62 165 -2.1 0.2 -1.7 -2.6 12/22/2006 03:30:00 10.4 2.2 15.6 5.3 10.5 2.2 15.3 5.7 9.9 2 15.6 6.1 52 13 43 165 -2.5 0 -2.1 -2.8 12/22/2006 03:40:00 12.5 2.1 16.4 7.6 12.5 2.2 16.4 7.2 12.2 2.3 16.8 6.1 37 10 39 165 -2.8 0 -2.6 -3 12/22/2006 03:50:00 12.4 1.4 15.6 8.4 12.1 1.7 15.6 7.2 12.1 1.5 15.6 8.8 26 9 46 165 -3 0 -2.8 -3 12/22/2006 04:00:00 12.6 2 17.6 8.8 12.2 2.2 17.6 7.2 12.2 1.9 17.9 8.4 21 11 27 165 -2.9 0 -2.6 -3 12/22/2006 04:10:00 13.7 2.2 19.1 9.1 13 2.3 19.1 7.6 13.2 2.2 19.1 8.8 19 9 25 165 -2.8 0.1 -2.4 -3 12/22/2006 04:20:00 14 1.7 17.9 9.5 13.3 2.1 17.6 7.6 13.5 1.7 17.9 9.1 19 10 22 165 -2.7 0.1 -2.4 -2.8 12/22/2006 04:30:00 15.7 1.7 19.5 11.1 14.4 2.4 18.7 7.2 15.2 1.9 19.5 10.3 14 9 16 165 -2.8 0 -2.6 -3 12/22/2006 04:40:00 14.6 1.7 18.3 10.3 13.4 2.6 18.3 7.2 14.1 1.9 18.7 9.9 16 10 27 165 -2.7 0.1 -2.4 -2.8 12/22/2006 04:50:00 14.1 1.5 19.1 10.7 11.2 2.8 18.7 6.5 13.8 1.7 19.9 9.9 8 11 14 165 -2.5 0 -2.1 -2.8 12/22/2006 05:00:00 13.6 1.4 17.6 9.9 10.3 1.9 16.4 6.5 13.5 1.5 17.6 9.9 7 9 19 165 -2.6 0 -2.6 -2.8 12/22/2006 05:10:00 13.5 1.5 17.2 9.9 10 1.8 15.6 5.7 13.5 1.6 18.3 9.5 5 9 11 165 -2.5 0 -2.1 -2.8 12/22/2006 05:20:00 13.4 1.4 17.2 9.5 9.9 1.7 15.6 6.1 13.4 1.5 17.6 8.8 4 12 344 165 -2.5 0 -2.4 -2.6 12/22/2006 05:30:00 13.8 2 19.1 9.1 10.6 2.4 17.9 6.1 13.8 2 19.1 9.9 6 10 288 165 -2.5 0 -2.1 -2.6 12/22/2006 05:40:00 13 1.6 18.3 9.5 10.1 2 16.1 6.5 13.1 1.7 18.7 8.8 4 13 9 165 -2.5 0 -2.1 -2.6 12/22/2006 05:50:00 12.1 1.6 17.6 8.8 9.6 1.7 14.5 5.7 11.8 1.7 17.2 8.4 6 12 333 165 -2.2 0 -2.1 -2.6 12/22/2006 06:00:00 14.5 1.7 19.1 9.5 11.5 2.3 18.3 6.1 14.3 2 19.5 9.9 7 12 5 165 -2 0.1 -1.9 -2.4 12/22/2006 06:10:00 13.4 1.5 18.3 9.5 10 2.1 18.3 6.8 13.4 1.6 17.9 9.1 3 13 22 165 -2 0 -1.7 -2.1 12/22/2006 06:20:00 13.1 1.9 17.2 8.8 10.7 2.2 16.4 5.7 13.2 1.7 17.2 9.1 7 13 11 165 -1.8 0 -1.7 -2.1 12/22/2006 06:30:00 13.5 1.8 17.9 8.4 11.8 1.8 16.4 6.1 13.2 1.9 18.7 7.6 10 13 1 165 -1.7 0 -1.4 -1.9 12/22/2006 06:40:00 11.5 1.7 16.4 6.5 10.4 2.2 16.8 5.7 11.4 1.9 17.2 6.1 13 13 17 165 -1.6 0 -1.4 -1.7 12/22/2006 06:50:00 11.5 2.1 17.2 7.2 11.2 2.4 17.2 6.1 11.5 2.2 17.9 7.2 22 14 33 165 -1.4 0 -1.2 -1.7 12/22/2006 07:00:00 12.6 1.5 16.4 8.8 11.9 1.9 16.4 6.5 12.5 1.7 17.9 8.4 18 12 22 165 -1.3 0 -1 -1.4 12/22/2006 07:10:00 10.2 1.5 14.1 6.8 9.2 1.7 14.1 4.6 10 1.7 14.9 5.7 16 15 21 165 -1.4 0 -1.2 -1.4 12/22/2006 07:20:00 10.9 1.7 13.7 6.8 10.6 1.7 13.7 5.7 10.4 1.7 14.1 5.3 40 13 44 165 -1.3 0 -1.2 -1.4 12/22/2006 07:30:00 11.2 1.8 14.9 6.1 11.1 1.9 14.9 6.1 11.4 1.7 16.1 5.7 32 11 41 165 -1.2 0 -1 -1.4 12/22/2006 07:40:00 10.8 2.2 15.6 6.1 10.7 2.2 15.6 6.1 10.8 2.3 16.1 5.7 38 13 36 165 -1.3 0 -1 -1.4 12/22/2006 07:50:00 12.8 2 17.2 7.6 12.7 2.1 17.2 7.2 13.2 2.2 17.9 8 31 12 43 165 -1.3 0.1 -1 -1.4 12/22/2006 08:00:00 12 1.5 15.6 8 11.9 1.5 15.6 7.2 12.2 1.5 17.2 8.8 34 11 37 165 -1.4 0 -1.2 -1.7 12/22/2006 08:10:00 12.7 2.3 18.7 7.6 12.5 2.4 18.3 6.8 12.7 2.6 19.9 6.8 33 12 19 165 -1.3 0 -1.2 -1.4 12/22/2006 08:20:00 14.4 1.9 17.9 8.8 14.3 2.1 17.9 8 14.5 2.2 19.9 9.5 29 12 36 165 -1.4 0 -1.2 -1.4 12/22/2006 08:30:00 13.5 2 18.3 8.4 13.3 2.1 18.7 7.6 13.7 2.1 19.9 8 29 12 35 165 -1.4 0 -1.2 -1.4 12/22/2006 08:40:00 14 1.9 18.3 9.1 13.7 2.1 18.3 7.2 14.1 2.1 19.1 8.4 24 13 36 165 -1.4 0.1 -1.2 -1.4 12/22/2006 08:50:00 13.6 1.7 17.9 8.8 13.3 1.8 17.6 8.4 13.7 2.1 19.1 9.5 28 13 43 165 -1.3 0 -1 -1.4 12/22/2006 09:00:00 12.8 2.2 17.9 8 12.5 2.2 17.6 7.2 12.9 2.3 19.5 8.8 25 11 32 165 -1.2 0 -1 -1.2 12/22/2006 09:10:00 13.6 2.4 18.7 7.6 13 2.6 18.3 6.1 13.5 2.4 19.5 8 22 11 32 165 -1.2 0 -1 -1.4 12/22/2006 09:20:00 13.1 1.7 17.2 9.5 11.7 2.2 16.8 6.1 13.2 1.7 16.8 9.1 16 9 11 165 -1.2 0 -1 -1.4 12/22/2006 09:30:00 13 1.7 18.7 8.8 10.7 2.2 17.9 5.7 13.1 2 19.9 9.1 12 7 21 165 -1.3 0 -1 -1.4 12/22/2006 09:40:00 13.5 1.6 17.2 9.5 11.7 2.3 16.4 6.8 13.6 1.7 17.9 9.1 14 8 11 165 -1.2 0 -1 -1.4 12/22/2006 09:50:00 14.4 1.7 17.9 9.5 12.7 2.5 17.6 6.8 14.3 1.9 18.7 9.1 15 8 25 165 -1.3 0 -1.2 -1.4 12/22/2006 10:00:00 14.7 2.1 19.5 10.7 13.7 2.5 19.1 8 14.7 2.3 20.2 9.5 18 8 22 165 -1.1 0 -0.8 -1.4 12/22/2006 10:10:00 14.3 2.2 19.1 9.5 12.6 3.2 17.9 6.1 14.1 2.3 20.2 8.4 14 10 12 165 -1.1 0 -0.8 -1.2 12/22/2006 10:20:00 13.7 1.6 17.6 9.5 9.9 2.5 16.8 6.1 13.4 1.7 17.9 9.5 7 8 12 165 -1.4 0.1 -1.2 -1.4 12/22/2006 10:30:00 13.5 2 17.9 9.5 9 2.2 15.3 5.3 13.6 2.2 17.9 8.4 1 5 359 165 -1.5 0 -1.4 -1.7 12/22/2006 10:40:00 13.2 1.8 17.9 8.8 9.7 2.5 16.4 5.7 13.2 2 18.3 7.2 359 4 359 165 -1.6 0 -1.4 -1.9 12/22/2006 10:50:00 13.3 2 19.1 8.8 9.3 2.4 17.9 5.3 13.4 2 19.9 9.1 4 7 11 165 -1.7 0 -1.4 -1.9 12/22/2006 11:00:00 13.8 1.8 19.5 10.3 10.5 2.3 16.1 6.1 13.7 1.9 19.1 9.1 358 10 3 165 -1.8 0.1 -1.7 -2.1 12/22/2006 11:10:00 13.8 2.4 21.8 8.8 10.9 2.6 17.6 5.3 13.6 2.3 20.6 9.1 355 10 9 165 -2 0 -1.9 -2.6 12/22/2006 11:20:00 17.5 2.2 23.3 11.8 14.1 2.8 20.6 8.4 17.6 2.6 24.4 10.7 353 12 10 165 -2.7 0.1 -2.1 -3 12/22/2006 11:30:00 18 2.4 24 11.1 13.2 2.4 20.2 8.8 17.9 2.7 25.6 11.1 356 10 2 165 -3 0.1 -2.8 -3 12/22/2006 11:40:00 18.9 2.5 25.6 12.6 15.2 2.9 21.8 9.1 18.8 2.4 26.8 12.2 349 11 3 165 -3.1 0 -2.8 -3.3 12/22/2006 11:50:00 19.3 2.4 26 13 13.8 2.8 20.6 7.6 19.2 2.6 25.6 12.6 354 10 353 165 -3.1 0 -2.8 -3.3 12/22/2006 12:00:00 19.1 2.6 27.5 13 13.7 2.7 20.6 8.4 19.4 2.6 26.8 13 353 11 353 165 -3.2 0 -3 -3.5 12/22/2006 12:10:00 19.7 2.4 25.6 13.7 13.9 3.5 23.7 8 19.8 2.6 26 12.6 355 12 352 165 -3.3 0 -3 -3.5 12/22/2006 12:20:00 20.4 3.2 28.3 8.4 15.4 3.6 26 8.8 20.6 3.3 28.7 9.1 356 15 9 165 -3.4 0 -3.3 -3.5 12/22/2006 12:30:00 20.8 2.9 27.1 13.3 15.4 3.2 22.9 7.2 21.1 3.2 28.3 14.1 353 12 350 165 -3.5 0 -3.3 -3.5 12/22/2006 12:40:00 20.8 2.5 28.7 14.9 15 2.8 23.7 8.4 21.4 2.8 29.8 15.3 353 13 1 165 -3.6 0 -3.5 -3.7 12/22/2006 12:50:00 21.7 2.7 28.3 14.5 16.3 3.5 26 9.9 22 2.9 29.8 14.5 352 13 340 165 -3.6 0 -3.3 -3.7 12/22/2006 13:00:00 22.6 3.1 30.9 15.3 16.5 3.6 26 9.1 23.2 3.5 33.2 14.9 353 15 3 165 -3.6 0 -3.3 -3.7 12/22/2006 13:10:00 20.1 3.1 26.8 11.8 15.5 3.3 23.3 8.4 20.7 3.3 28.7 12.2 355 15 322 165 -3.5 0 -3.3 -3.5 12/22/2006 13:20:00 18.9 2.9 28.7 11.8 15.7 3.5 27.1 8 19.4 3.5 29.8 9.5 356 20 359 165 -3.5 0 -3.3 -3.5 12/22/2006 13:30:00 17.2 2.8 27.5 11.8 13.8 2.8 25.6 7.6 17.2 3.3 29.4 11.1 347 16 11 165 -3.5 0 -3.3 -3.5 12/22/2006 13:40:00 15.5 2.1 21 9.9 13.3 1.8 17.6 7.2 15.6 2.1 21.8 10.3 342 16 5 165 -3.7 0 -3.5 -3.9 12/22/2006 13:50:00 17.5 2.6 25.2 11.5 16.1 2.6 24 8.4 17.4 2.7 25.6 11.5 333 15 329 165 -3.9 0.1 -3.5 -4.2 12/22/2006 14:00:00 16.8 2.6 25.2 10.3 15.9 2.7 24 9.9 16.9 2.6 24.8 8.8 335 17 23 165 -4.1 0.1 -3.9 -4.4 12/22/2006 14:10:00 17.6 3.5 27.1 8.8 16.9 3.5 26.3 8.8 17.6 3.5 26 9.1 325 20 333 165 -4.3 0 -4.2 -4.6 12/22/2006 14:20:00 21.3 4 31.3 13 20.7 4 31.3 13 21.4 4.1 31.8 13 325 15 335 165 -4.4 0 -4.4 -4.6 12/22/2006 14:30:00 23.4 3.5 30.9 13 23.1 3.3 29.8 12.6 24.3 3.8 33.2 13.7 323 10 323 165 -4.5 0 -4.4 -4.6 12/22/2006 14:40:00 23.9 3.8 33.2 15.3 24.1 4.1 34.8 13 24.9 4.5 38.6 13.7 326 11 323 165 -4.7 0 -4.4 -4.8 12/22/2006 14:50:00 21.1 3.8 32.4 12.2 22.9 4.3 36.3 13.7 22.5 4.9 38.2 10.7 320 12 314 165 -4.5 0 -4.4 -4.6 12/22/2006 15:00:00 18.6 3.1 26.3 11.5 19.7 3.8 29.1 11.1 19.6 3.6 29.8 11.1 326 15 317 165 -4.4 0 -4.4 -4.6 12/22/2006 15:10:00 22.8 3.2 36.3 14.9 24.5 3.6 37.8 16.4 24.3 3.6 36.3 16.1 324 10 306 165 -4.4 0 -4.2 -4.6 12/22/2006 15:20:00 24.6 3.2 34 16.4 26.2 4 36.3 13.7 26.2 3.8 36.7 16.8 325 10 312 165 -4.4 0 -4.2 -4.6 12/22/2006 15:30:00 25.2 4.1 36.3 14.1 26.3 5.4 39.8 13.3 26.3 4.7 38.6 13.3 328 14 309 165 -4.5 0 -4.4 -4.6 12/22/2006 15:40:00 25.2 4.7 37.5 14.5 26.9 5.4 42.1 11.1 26.5 5.1 38.6 15.3 324 12 332 165 -4.5 0 -4.4 -4.6 12/22/2006 15:50:00 23.5 3.6 36.3 16.8 25.1 4.3 39.8 14.9 24.7 4.3 40.1 16.8 326 11 308 165 -4.6 0 -4.4 -4.6 12/22/2006 16:00:00 25.1 4.1 39.8 16.4 26.3 4.5 41.3 16.8 25.9 4.3 40.5 17.6 327 13 277 165 -4.4 0 -4.2 -4.6 12/22/2006 16:10:00 24.9 3.6 34.8 14.9 26.1 4.3 36.7 11.5 25.8 4 35.9 14.9 325 12 304 165 -4.3 0 -4.2 -4.6 12/22/2006 16:20:00 21.8 4.1 36.3 11.5 22.6 4.7 37.5 11.5 22.8 4.1 34.8 11.1 327 15 341 165 -4.3 0 -4.2 -4.4 12/22/2006 16:30:00 23.2 3.5 34.4 12.2 24 4.1 36.3 12.2 24.2 4 35.5 14.9 329 11 330 165 -4.2 0 -3.9 -4.4 12/22/2006 16:40:00 21.4 3.1 30.6 12.6 22.3 3.3 32.9 13 21.8 3.6 32.9 11.8 322 14 319 165 -4.1 0 -3.9 -4.4 12/22/2006 16:50:00 21.9 3.8 33.6 12.6 22.5 4.3 34.8 10.7 22.4 4.1 36.3 12.2 328 12 311 165 -4 0 -3.9 -4.2 12/22/2006 17:00:00 24.4 3.6 34.4 15.6 25.3 4.1 35.9 14.1 25.2 4.1 35.9 16.1 326 12 338 165 -4 0 -3.9 -4.2 12/22/2006 17:10:00 25.7 4.3 41.3 12.2 26.2 4.5 42.8 10.7 26.4 4.1 39.4 11.8 326 12 320 165 -3.9 0 -3.7 -4.2 12/22/2006 17:20:00 27.8 3.6 37.1 17.2 28 4 38.6 17.6 26.4 4 37.5 16.1 328 10 323 165 -3.8 0 -3.5 -3.9 12/22/2006 17:30:00 26 4.5 35.9 14.5 26.1 4.9 37.5 14.1 24.7 4.5 37.1 13.7 327 11 311 165 -3.7 0 -3.5 -3.9 12/22/2006 17:40:00 27.4 4.5 38.6 14.9 27.7 5.1 40.9 15.6 26.7 4.7 42.4 14.5 326 11 309 165 -3.8 0 -3.5 -3.9 12/22/2006 17:50:00 28.4 3.6 38.2 16.8 28.4 4.1 39.4 15.6 27.4 3.8 39 17.9 332 10 328 165 -3.7 0 -3.5 -3.9 12/22/2006 18:00:00 25.4 2.9 34 17.2 25.7 3.2 34.4 17.2 24.4 2.8 34 16.8 330 10 339 165 -3.6 0 -3.5 -3.7 12/22/2006 18:10:00 24.6 3.3 35.2 17.6 25 3.5 34.4 16.8 23.6 3.3 34.4 16.4 331 9 324 165 -3.6 0 -3.5 -3.7 12/22/2006 18:20:00 25.6 3.5 32.9 14.5 25.8 4 35.9 15.6 25 3.8 34 13 332 10 339 165 -3.6 0 -3.5 -3.7 12/22/2006 18:30:00 26.5 4.1 40.9 15.6 26.5 4.3 40.9 14.9 26.2 4.3 39.4 15.6 333 10 349 165 -3.6 0 -3.3 -3.7 12/22/2006 18:40:00 25.4 3.2 33.2 16.8 26.1 3.8 35.2 14.1 25 3.5 32.4 15.3 333 10 340 165 -3.5 0 -3.3 -3.5 12/22/2006 18:50:00 24.8 3.6 32.1 16.1 25.4 4.3 34.8 15.6 24.5 3.6 32.4 13.7 335 10 334 165 -3.4 0 -3.3 -3.5 12/22/2006 19:00:00 24.9 3.2 37.1 17.9 25.2 3.6 37.1 14.9 24.7 3.3 35.9 16.8 336 12 360 165 -3.4 0 -3.3 -3.5 12/22/2006 19:10:00 24.2 3.3 32.4 16.1 24.8 3.6 32.1 14.9 24.7 3.6 32.4 15.6 331 11 333 165 -3.5 0 -3.3 -3.5 12/22/2006 19:20:00 22.9 3.5 34.8 14.9 23.4 3.6 34 13.3 23.2 3.6 35.5 14.9 333 9 339 165 -3.5 0 -3.3 -3.5 12/22/2006 19:30:00 26 3.3 33.2 14.5 26.6 4 35.5 13.3 26.5 3.5 34.8 14.9 332 11 336 165 -3.4 0 -3.3 -3.5 12/22/2006 19:40:00 22.7 4 35.5 14.5 22.8 4.1 37.5 14.9 23 4 35.9 14.5 333 13 342 165 -3.4 0 -3.3 -3.5 12/22/2006 19:50:00 20.2 3.6 32.9 13 20.6 3.8 30.9 10.7 20.4 4 32.4 10.3 330 15 347 165 -3.5 0 -3.3 -3.5 12/22/2006 20:00:00 19.8 2.6 27.1 13.7 20.4 2.7 26.8 12.6 20.2 2.6 27.1 14.1 330 10 333 165 -3.5 0 -3.3 -3.5 12/22/2006 20:10:00 20.2 3.3 30.9 13 20.8 3.5 32.1 12.2 20.6 3.6 31.8 13 332 11 338 165 -3.5 0 -3.3 -3.5 12/22/2006 20:20:00 20.5 2.7 27.5 14.9 20.4 2.7 29.1 12.6 20.5 3.1 27.9 12.2 334 14 327 165 -3.5 0 -3.3 -3.5 12/22/2006 20:30:00 20.3 2.3 28.3 13.7 20.2 2.5 28.7 14.5 20.2 2.5 29.1 11.8 337 13 337 165 -3.6 0 -3.5 -3.9 12/22/2006 20:40:00 20.5 3.2 28.7 13.3 21 3.3 30.2 11.8 20.7 3.2 29.1 13.3 331 10 343 165 -3.7 0 -3.5 -3.9 12/22/2006 20:50:00 21.9 3.8 32.1 13.3 22.1 3.8 32.1 14.1 22.2 3.8 31.3 13.7 330 10 329 165 -3.6 0 -3.3 -3.9 12/22/2006 21:00:00 19.2 3.2 27.1 11.1 19.5 3.3 28.7 12.2 19.3 3.2 27.1 11.8 328 16 330 165 -3.7 0 -3.5 -3.9 12/22/2006 21:10:00 18.9 2.9 29.4 12.6 19.4 3.1 29.8 13.3 19 3.1 31.3 11.5 327 14 336 165 -3.8 0 -3.5 -3.9 12/22/2006 21:20:00 20.9 2.3 27.9 13.7 21.3 2.6 27.9 14.5 20.9 2.5 27.9 14.1 331 13 317 165 -3.8 0 -3.5 -3.9 12/22/2006 21:30:00 21.4 2.4 28.7 15.3 21.4 2.6 29.8 13 21.8 2.4 29.1 16.1 332 13 319 165 -3.9 0 -3.7 -4.2 12/22/2006 21:40:00 21.8 2.9 28.3 11.5 21.7 3.2 28.7 11.5 22.2 3.1 29.1 12.6 335 12 349 165 -3.9 0 -3.7 -4.2 12/22/2006 21:50:00 19.9 2.1 26 14.5 20.6 2.2 27.1 14.5 20.1 2.5 26 13.3 325 12 329 165 -4 0 -3.7 -4.2 12/22/2006 22:00:00 21.8 2.4 28.3 14.5 22.1 2.3 28.7 14.9 22.1 2.5 28.7 16.1 327 12 328 165 -4 0 -3.9 -4.4 12/22/2006 22:10:00 22.2 3.1 31.8 14.9 22.7 3.1 32.1 15.6 22.2 3.1 32.4 14.1 320 13 326 165 -4 0 -3.7 -4.2 12/22/2006 22:20:00 21.3 2.2 28.7 16.1 22 2.4 29.8 16.4 21.3 2.5 28.7 15.3 324 15 325 165 -4 0 -3.9 -4.2 12/22/2006 22:30:00 22.3 2.4 28.3 16.4 22.6 2.5 29.1 16.4 22.6 2.5 31.3 15.3 324 13 326 165 -4.1 0 -3.9 -4.4 12/22/2006 22:40:00 21 2.5 27.5 14.1 21.6 2.5 29.1 12.6 20.4 2.7 26.3 13.3 310 13 304 165 -4.1 0 -3.9 -4.4 12/22/2006 22:50:00 20.7 3.1 29.1 11.8 21.2 3.1 29.8 11.5 20.6 3.2 29.1 13 316 15 331 165 -4 0 -3.9 -4.4 12/22/2006 23:00:00 19.2 2.5 25.2 10.7 19.7 2.7 26.8 9.5 19.3 2.7 27.5 11.8 324 17 344 165 -4.1 0 -3.9 -4.2 12/22/2006 23:10:00 18.1 2 24 12.2 18.5 2.1 24.4 12.2 18.4 2.2 26.3 12.2 329 11 326 165 -4.1 0 -3.9 -4.4 12/22/2006 23:20:00 21.1 2.8 28.7 13.3 21.3 2.9 29.1 13.7 21.4 2.8 30.9 14.1 330 13 337 165 -4 0 -3.9 -4.2 12/22/2006 23:30:00 25.3 2.9 32.9 18.3 25.3 3.3 34.8 14.9 25.9 3.1 33.6 17.6 338 10 349 165 -3.8 0 -3.5 -3.9 12/22/2006 23:40:00 22.6 3.5 34 15.6 22.3 3.3 33.2 13.3 23 3.3 34 17.2 335 12 349 165 -3.6 0 -3.3 -3.7 12/22/2006 23:50:00 19.8 2.4 27.9 13.7 20.2 2.6 28.7 10.7 19.5 2.6 25.6 10.7 318 16 289 165 -3.5 0 -3.3 -3.7 12/23/2006 00:00:00 20.8 2.3 26.8 14.1 21.2 2.4 27.1 14.1 20.1 2.6 27.9 13.3 309 11 314 165 -3.2 0 -3 -3.5 12/23/2006 00:10:00 20.9 2.8 28.3 13 21.3 2.7 29.1 13.3 20.8 2.8 27.9 13.7 315 10 320 165 -3.3 0.1 -3 -3.5 12/23/2006 00:20:00 22.2 2.1 27.1 16.4 22.6 2 27.9 16.4 21.3 2.5 29.4 16.1 309 9 310 165 -3.6 0 -3.3 -3.9 12/23/2006 00:30:00 22.3 2.5 29.4 16.1 22.8 2.4 29.1 16.4 22.2 2.5 30.6 16.8 313 9 319 165 -3.7 0 -3.3 -3.9 12/23/2006 00:40:00 23.4 2.2 28.3 17.6 23.9 2.1 28.7 17.9 23.2 2.1 28.7 15.3 312 8 313 165 -3.8 0 -3.5 -3.9 12/23/2006 00:50:00 21.8 2.2 28.7 16.8 22.3 2.2 28.7 17.2 22.1 2.1 29.1 16.4 314 7 325 165 -3.9 0.1 -3.5 -4.4 12/23/2006 01:00:00 23.7 1.9 28.3 17.2 24.1 1.8 28.7 18.3 24 2.1 29.1 16.1 314 6 310 165 -4 0 -3.7 -4.2 12/23/2006 01:10:00 24.5 2 29.1 19.9 24.8 1.9 29.4 20.2 24.6 2 29.1 19.9 312 6 302 165 -3.9 0 -3.7 -4.2 12/23/2006 01:20:00 23.1 2.1 27.9 17.6 23.5 2 28.3 18.7 23.3 2.1 28.3 16.8 313 6 304 165 -3.9 0 -3.5 -4.4 12/23/2006 01:30:00 23 1.9 27.9 18.3 23.5 1.9 28.3 19.1 23.2 1.9 28.3 17.9 313 6 312 165 -3.8 0 -3.5 -4.2 12/23/2006 01:40:00 23 1.7 27.5 17.9 23.4 1.7 28.3 18.7 23.3 2 29.1 18.3 314 6 310 165 -3.7 0.1 -3.3 -3.9 12/23/2006 01:50:00 22.8 1.7 27.1 17.6 23.2 1.7 27.5 18.7 23.1 1.7 27.9 17.9 314 6 314 165 -3.5 0 -3.3 -3.5 12/23/2006 02:00:00 22.1 1.7 26.3 17.2 22.6 1.7 27.5 17.2 22.3 1.9 26.8 16.4 313 7 300 165 -3.6 0 -3.3 -3.7 12/23/2006 02:10:00 20.9 1.9 26.3 15.6 21.3 1.9 27.1 15.3 21.2 2 26.8 15.3 315 7 308 165 -3.5 0.1 -3.3 -3.7 12/23/2006 02:20:00 20.2 1.7 25.2 15.3 20.6 1.7 25.2 15.6 20 1.7 24.4 15.6 312 8 299 165 -3.7 0 -3.3 -3.9 12/23/2006 02:30:00 21.1 1.6 27.5 16.8 21.3 1.6 27.5 16.8 20.5 1.6 26.3 16.8 311 6 311 165 -3.5 0.1 -3.3 -3.7 12/23/2006 02:40:00 22.2 1.5 27.1 18.7 22.3 1.5 27.5 18.3 21.4 1.7 26.8 16.8 311 6 317 165 -3.5 0 -3.3 -3.5 12/23/2006 02:50:00 22.3 1.8 27.1 15.6 22.3 1.7 27.1 17.2 21.7 2.2 27.9 15.3 311 6 309 165 -3.4 0.1 -3 -3.5 12/23/2006 03:00:00 22.2 1.5 26.3 18.3 22.1 1.3 26.8 17.9 21.7 1.6 27.5 17.6 313 6 317 165 -3.6 0 -3.3 -3.7 12/23/2006 03:10:00 22.5 1.5 26.8 17.2 22.3 1.5 26.8 16.8 22.4 1.5 26.3 17.6 314 5 313 165 -3.5 0.1 -3.3 -3.7 12/23/2006 03:20:00 22.4 1.6 26.3 17.9 22.3 1.5 26.8 17.6 21.8 1.7 26.3 17.9 312 5 298 165 -3.6 0 -3.5 -3.7 12/23/2006 03:30:00 21.9 1.7 26 17.2 21.7 1.7 25.2 16.8 20.9 1.8 26.3 15.3 312 7 315 165 -3.5 0 -3.3 -3.9 12/23/2006 03:40:00 21.6 1.4 24.8 18.3 21.4 1.4 24.8 17.6 20.6 1.5 23.7 16.8 312 6 290 165 -3.6 0.1 -3.3 -3.7 12/23/2006 03:50:00 21.2 1.4 24.8 17.2 21 1.3 24 17.6 20.2 1.3 23.3 15.3 311 6 310 165 -3.7 0 -3.5 -3.9 12/23/2006 04:00:00 21.6 1.5 25.6 16.1 21.4 1.5 25.6 15.6 20.1 1.8 24.8 14.9 310 6 310 165 -3.8 0 -3.5 -4.2 12/23/2006 04:10:00 21.3 1.6 26.3 14.9 21.1 1.6 26 15.3 20 1.7 26 15.6 311 6 304 165 -3.8 0 -3.5 -4.2 12/23/2006 04:20:00 21.8 1.5 26 16.8 21.6 1.5 25.6 16.4 20.2 1.7 24.4 15.6 309 6 290 165 -3.7 0 -3.5 -3.9 12/23/2006 04:30:00 21.5 1.3 24.4 17.6 21.2 1.3 24.4 17.2 19.3 1.8 24 14.5 307 6 304 165 -3.9 0 -3.7 -4.2 12/23/2006 04:40:00 22.2 1.7 26.8 17.9 22 1.7 26.3 17.9 20.4 2 25.2 15.3 309 6 306 165 -3.8 0.2 -3.5 -4.2 12/23/2006 04:50:00 21.4 1.6 27.5 17.9 21.1 1.6 27.1 17.6 19.3 1.9 27.9 14.9 307 8 312 165 -3.8 0 -3.5 -3.9 12/23/2006 05:00:00 20.4 1.6 24.8 16.8 20.2 1.6 24.4 16.4 18 1.7 22.6 13 306 7 312 165 -3.8 0 -3.5 -3.9 12/23/2006 05:10:00 19.8 1.7 24 15.3 19.5 1.6 23.7 15.3 16.8 2 21.8 11.8 305 8 307 165 -3.7 0 -3.5 -3.9 12/23/2006 05:20:00 19.7 1.8 24.8 14.1 19.4 1.7 24 14.5 17 2 22.1 11.8 305 6 302 165 -3.7 0.1 -3.5 -3.9 12/23/2006 05:30:00 19.5 1.5 22.6 13 19.2 1.4 22.1 12.6 16.9 1.7 21.4 13 308 7 309 165 -3.9 0 -3.7 -4.2 12/23/2006 05:40:00 17.9 1.6 22.9 12.6 17.6 1.6 23.3 12.6 16.2 2.2 23.7 9.9 310 8 312 165 -3.8 0.1 -3.5 -4.2 12/23/2006 05:50:00 16.4 1.8 24 12.2 16.2 1.7 24 11.8 14.7 2.1 21.4 9.9 308 9 302 165 -3.6 0.2 -3 -4.2 12/23/2006 06:00:00 15.2 1.7 19.5 10.3 15 1.7 19.5 10.3 13.8 2 18.7 8.4 308 11 282 165 -3.6 0.3 -2.8 -4.2 12/23/2006 06:10:00 17.3 1.6 22.6 12.6 17 1.5 22.6 13 13.7 1.9 19.5 9.1 300 8 304 165 -3.8 0.2 -3.3 -4.4 12/23/2006 06:20:00 16.8 1.4 20.6 12.2 16.6 1.3 21 12.2 13.3 1.9 21.4 8.8 302 7 307 165 -4.2 0 -3.9 -4.4 12/23/2006 06:30:00 17.1 1.4 21 13.7 16.9 1.3 20.6 13.3 13.3 1.6 17.9 9.5 302 6 301 165 -4.2 0 -3.9 -4.4 12/23/2006 06:40:00 16.1 1.3 20.6 11.8 15.9 1.3 19.5 11.8 12.6 1.7 18.7 9.5 304 6 302 165 -4 0 -3.7 -4.2 12/23/2006 06:50:00 17 1.1 19.5 14.1 16.7 1.1 19.1 13.3 14.6 1.2 17.9 11.1 308 5 297 165 -3.9 0 -3.7 -4.2 12/23/2006 07:00:00 17.4 1.2 21.4 14.1 17.2 1.2 20.6 14.1 15 1.2 18.7 12.2 308 4 302 165 -3.9 0 -3.7 -4.2 12/23/2006 07:10:00 18 1.1 21 14.9 17.8 1.1 21 14.5 15.3 1.3 19.1 11.5 306 6 313 165 -3.7 0 -3.5 -3.9 12/23/2006 07:20:00 17.2 1.1 21.4 14.1 17 1.1 20.2 13.7 14 1.4 17.9 10.3 305 5 314 165 -3.7 0 -3.5 -3.9 12/23/2006 07:30:00 17.6 1.2 20.6 13.7 17.4 1.2 20.2 13.7 14.6 1.6 18.3 9.9 306 5 307 165 -3.8 0 -3.5 -3.9 12/23/2006 07:40:00 17.4 1 19.5 13.7 17.2 1 19.1 13.3 15.5 1.7 19.5 10.7 309 6 305 165 -3.7 0 -3.3 -3.9 12/23/2006 07:50:00 16.4 0.8 18.7 13.7 16.2 0.8 18.3 13.3 14.5 1.4 17.6 10.7 309 5 305 165 -3.8 0 -3.5 -3.9 12/23/2006 08:00:00 16.5 1.3 19.5 12.6 16.3 1.3 19.1 12.6 14 1.7 17.6 9.5 307 6 305 165 -3.7 0.1 -3.3 -3.9 12/23/2006 08:10:00 16.1 1.2 18.7 13 15.8 1.2 18.7 12.6 13.7 1.5 17.6 9.9 307 6 303 165 -3.4 0 -3.3 -3.5 12/23/2006 08:20:00 16.2 1.3 19.5 12.6 16 1.3 19.1 12.6 13.9 1.3 17.9 10.7 306 6 300 165 -3.4 0.1 -3 -3.7 12/23/2006 08:30:00 15.5 1.3 17.6 11.8 15.2 1.3 17.6 11.8 14.5 1.4 17.6 10.7 310 6 306 165 -3.7 0 -3.5 -3.9 12/23/2006 08:40:00 16.9 1.2 19.1 13 16.6 1.2 19.5 13 16.1 1.3 19.5 11.8 312 5 311 165 -3.6 0 -3.3 -3.9 12/23/2006 08:50:00 17.6 1.5 20.6 13.3 17.3 1.4 20.6 13.7 15.6 1.7 19.9 11.5 307 5 307 165 -3.5 0 -3.3 -3.5 12/23/2006 09:00:00 16.9 1.1 20.2 13.7 16.6 1.1 20.2 13.7 15.6 1.7 20.2 10.7 309 6 305 165 -3.5 0 -3.3 -3.5 12/23/2006 09:10:00 17.3 0.9 19.9 14.9 17.1 0.9 19.9 14.9 15.9 1.3 19.5 10.7 310 5 305 165 -3.5 0 -3.3 -3.7 12/23/2006 09:20:00 15.8 1.1 18.7 12.6 15.5 1.1 18.3 12.2 15.3 1.4 18.3 9.1 317 6 317 165 -3.5 0 -3.3 -3.5 12/23/2006 09:30:00 15.9 1.2 18.7 12.2 15.6 1.2 18.3 13 15.5 1.3 18.7 11.5 317 6 317 165 -3.5 0 -3.3 -3.5 12/23/2006 09:40:00 14.3 1.7 17.9 9.5 14 1.6 17.9 9.5 14.1 1.9 17.9 9.1 320 8 326 165 -3.4 0 -3.3 -3.5 12/23/2006 09:50:00 12.7 1.5 17.6 9.1 12.5 1.5 17.6 8.8 12.3 1.6 17.6 8 318 8 314 165 -3.5 0 -3.3 -3.7 12/23/2006 10:00:00 12.4 1.3 15.6 8.4 12.2 1.3 15.3 8.4 11.4 1.3 16.1 8.4 313 9 288 165 -3.6 0.1 -3.3 -3.9 12/23/2006 10:10:00 13.8 1.3 16.8 10.3 13.5 1.2 16.4 10.3 12.3 1.2 14.9 8.4 308 8 301 165 -3.7 0 -3.5 -3.9 12/23/2006 10:20:00 14 1.3 18.3 10.3 13.8 1.3 18.3 9.9 12.8 1.3 16.8 9.5 310 9 301 165 -3.5 0 -3.3 -3.9 12/23/2006 10:30:00 14.4 1.6 19.1 9.9 14.2 1.5 18.7 9.9 13.2 1.7 17.9 8.4 311 8 310 165 -3 0.1 -2.8 -3.5 12/23/2006 10:40:00 14 1.5 19.9 9.9 13.9 1.5 19.5 9.9 12.9 1.6 17.2 9.1 310 10 301 165 -2.8 0 -2.6 -3 12/23/2006 10:50:00 14.9 1.4 17.9 10.7 14.8 1.3 17.6 10.7 13.6 1.5 17.6 9.5 308 8 285 165 -2.5 0 -2.6 -2.8 12/23/2006 11:00:00 14.6 1.6 17.6 9.9 14.5 1.5 17.6 9.9 13.1 1.5 16.8 9.1 307 8 309 165 -2.5 0 -2.1 -2.8 12/23/2006 11:10:00 13.1 1.7 17.6 8.8 13.1 1.7 17.2 8.8 10.7 2.1 16.8 5.7 302 9 304 165 -2.1 0.2 -1.7 -2.6 12/23/2006 11:20:00 11.9 2.2 16.1 7.2 11.9 2.1 16.1 7.6 9.7 2.3 16.1 5.3 302 11 310 165 -1.7 0 -1.4 -1.9 12/23/2006 11:30:00 11.9 1.2 15.3 8.4 11.9 1.1 15.3 8.8 9.7 1.5 13.3 4.2 301 9 301 165 -1.7 0.1 -1.4 -2.1 12/23/2006 11:40:00 11.3 1.5 14.9 7.2 11.4 1.4 14.5 7.2 9.1 1.7 13 4.9 302 9 299 165 -1.4 0.1 -1.2 -1.9 12/23/2006 11:50:00 10.8 1.5 14.1 5.3 10.8 1.5 13.7 5.7 8.3 2.1 12.2 2.3 300 10 299 165 -1.2 0 -0.8 -1.4 12/23/2006 12:00:00 11.2 1.6 15.3 6.5 11.2 1.6 15.3 6.1 8.8 1.8 14.5 3.8 299 12 305 165 -1.2 0.1 -0.8 -1.4 12/23/2006 12:10:00 10.8 2 14.9 4.2 10.8 2.1 15.3 3 8.9 2.5 14.5 1.5 307 14 274 165 -1.2 0 -0.8 -1.4 12/23/2006 12:20:00 12.5 2.2 17.2 6.1 12.4 2.2 17.2 6.1 11.4 2.4 16.8 4.9 313 11 326 165 -1.3 0 -0.8 -1.4 12/23/2006 12:30:00 12.2 2.3 18.3 5.7 12.1 2.3 17.6 5.7 10.9 2.1 16.8 5.7 312 9 310 165 -1.3 0 -1 -1.4 12/23/2006 12:40:00 11.5 2.1 17.2 7.2 11.4 2 17.2 7.2 10.1 2 15.6 4.9 309 15 291 165 -0.9 0.1 -0.5 -1.2 12/23/2006 12:50:00 12.8 2.3 19.1 6.8 12.7 2.3 19.1 6.8 11.7 2.3 17.2 5.3 313 13 289 165 -0.6 0 -0.5 -0.8 12/23/2006 13:00:00 13.1 1.9 18.7 8.4 13 1.8 18.7 8.4 11.5 1.9 16.4 6.8 309 11 295 165 -0.6 0.1 -0.3 -1 12/23/2006 13:10:00 14.2 2.2 19.1 8.8 14.1 2.1 19.1 8 12.9 2 18.7 8 313 13 298 165 -0.5 0 -0.3 -0.8 12/23/2006 13:20:00 12.8 2.4 19.5 6.8 12.7 2.4 19.5 6.8 11.5 2.5 17.2 6.1 312 11 307 165 -0.5 0 -0.3 -0.8 12/23/2006 13:30:00 12.7 2.4 17.6 4.9 12.6 2.4 17.9 4.6 11.2 2.4 17.6 5.7 311 13 312 165 -0.5 0.1 -0.1 -0.8 12/23/2006 13:40:00 9.6 1.9 14.9 4.9 9.5 1.9 14.9 4.6 8.8 2 13.3 2.3 317 13 322 165 -0.3 0 -0.1 -0.5 12/23/2006 13:50:00 8.6 1.9 14.5 3.4 8.5 1.8 14.5 3.8 8 2.1 13 3.4 319 18 287 165 -0.3 0.1 0.2 -0.5 12/23/2006 14:00:00 8.6 1.5 14.5 5.3 8.5 1.5 14.9 5.7 8 1.6 14.1 5.3 317 15 314 165 -0.3 0.1 -0.1 -0.5 12/23/2006 14:10:00 7.7 1.5 11.1 3.8 7.5 1.5 11.5 3.4 6.8 1.6 11.1 3 311 11 318 165 -0.6 0 -0.3 -0.8 12/23/2006 14:20:00 8.5 1.5 14.1 4.9 8.4 1.5 14.5 5.3 8 1.5 13.3 4.9 315 12 322 165 -0.6 0 -0.3 -0.8 12/23/2006 14:30:00 8.4 1.2 12.2 5.3 8.3 1.2 11.8 5.3 7.9 1.3 12.6 4.6 315 9 301 165 -0.6 0 -0.5 -0.8 12/23/2006 14:40:00 10.4 1.6 14.5 6.8 10.2 1.5 14.9 7.2 9.6 1.7 13.7 4.2 314 9 300 165 -0.9 0 -0.5 -1.2 12/23/2006 14:50:00 11.4 1.7 16.8 7.2 11.2 1.7 17.2 6.8 10.7 1.7 16.4 6.5 316 8 308 165 -1 0 -0.8 -1.2 12/23/2006 15:00:00 11 1.5 16.1 7.6 10.9 1.5 15.3 7.6 10.2 1.5 14.9 6.5 315 10 303 165 -1.2 0 -0.8 -1.4 12/23/2006 15:10:00 10.1 1.7 13.3 5.7 10 1.7 13.3 5.3 9.1 1.8 13 4.6 310 10 296 165 -1.2 0.1 -1 -1.4 12/23/2006 15:20:00 10.2 1.4 13.3 4.6 10.1 1.3 13.7 4.9 9.1 1.6 12.6 4.9 309 10 302 165 -1.4 0 -1.2 -1.7 12/23/2006 15:30:00 9.6 1.4 13.3 5.3 9.5 1.3 13.3 6.1 8.6 1.5 12.6 4.9 308 10 290 165 -1.5 0 -1.2 -1.9 12/23/2006 15:40:00 8.2 1 11.1 5.7 8.2 1 11.1 5.7 7.2 1.1 10.7 4.2 310 12 287 165 -1.9 0.1 -1.4 -2.4 12/23/2006 15:50:00 7.2 1.1 10.3 3 7.1 1.2 10.7 3 6.4 1.2 9.5 3 311 13 294 165 -2.3 0 -2.1 -2.6 12/23/2006 16:00:00 5.3 1.2 8.4 2.6 5.2 1.2 8.4 2.3 4.9 1 8.4 2.3 320 13 302 165 -2.5 0.1 -2.1 -2.8 12/23/2006 16:10:00 4.4 1.2 7.6 1.5 4.3 1.2 7.6 1.5 3.8 1.1 6.5 1.9 326 21 280 165 -3.2 0.1 -2.6 -3.5 12/23/2006 16:20:00 4.9 0.8 7.2 2.3 4.9 0.8 7.2 2.6 4.7 0.9 8 2.6 317 12 299 165 -2.8 0 -2.6 -3.5 12/23/2006 16:30:00 5.3 1 8.4 2.6 5.2 1.1 8.4 2.6 4.7 0.9 7.2 2.3 314 18 301 165 -2.9 0 -2.8 -3 12/23/2006 16:40:00 3.5 0.7 5.3 1.9 3.4 0.8 5.3 1.5 3 0.9 4.9 1.1 329 17 325 165 -3.2 0 -2.8 -3.5 12/23/2006 16:50:00 3.7 1 6.5 1.5 3.7 1 6.8 1.5 3.4 1 6.5 1.1 320 19 302 165 -3.2 0 -3 -3.5 12/23/2006 17:00:00 5.1 1 8.4 3 5.1 1.1 8.8 3 4.2 1 6.5 2.3 310 15 299 165 -3.3 0 -3 -3.5 12/23/2006 17:10:00 5.4 1.1 8.8 3 5.3 1.1 9.1 2.6 5.3 1.1 8.8 2.3 326 11 332 165 -3.1 0.1 -2.6 -3.5 12/23/2006 17:20:00 7.4 1.4 12.6 4.6 7.3 1.4 12.2 4.6 6.7 1.2 11.1 4.2 317 11 301 165 -2.7 0.1 -2.6 -3 12/23/2006 17:30:00 7.8 1.4 10.7 3.8 7.8 1.4 11.1 3 6.5 1.9 10.7 1.9 310 12 306 165 -2.8 0.1 -2.6 -3 12/23/2006 17:40:00 8.8 1.5 13 6.1 8.8 1.5 13 6.1 8 1.6 12.2 4.6 316 11 322 165 -2.6 0 -2.4 -2.8 12/23/2006 17:50:00 8.9 1.5 13 5.7 8.8 1.5 12.6 5.7 8.1 1.7 12.2 4.6 315 8 313 165 -2.4 0 -2.1 -2.6 12/23/2006 18:00:00 9 1.1 11.8 6.5 8.9 1.1 11.8 6.1 8.2 1.3 11.5 4.6 312 12 297 165 -2.2 0 -1.9 -2.6 12/23/2006 18:10:00 9.1 1.2 11.8 5.7 9 1.2 11.5 5.7 8 1.4 10.7 4.2 313 12 317 165 -2.2 0 -1.9 -2.4 12/23/2006 18:20:00 8.1 1.5 11.5 3.8 8.2 1.5 11.8 3.8 7.3 1.5 11.1 3.8 315 13 306 165 -2.4 0 -2.1 -2.6 12/23/2006 18:30:00 7.2 1.4 10.7 3 7.2 1.5 11.5 3 6.1 1.5 10.7 2.3 312 14 311 165 -2.5 0.1 -2.1 -2.6 12/23/2006 18:40:00 7.6 1.3 11.1 4.9 7.6 1.3 11.8 4.9 6.7 1.5 11.1 3.4 310 13 302 165 -2.5 0.1 -2.1 -2.8 12/23/2006 18:50:00 6.5 1.1 8.8 3 6.5 1.2 9.5 3 5.8 1.2 8.4 2.6 311 10 310 165 -2.3 0 -2.1 -2.6 12/23/2006 19:00:00 6 1.3 10.3 3.4 6 1.3 9.9 3.4 5.1 1.5 9.1 2.3 307 10 312 165 -2.5 0.1 -2.1 -2.8 12/23/2006 19:10:00 4.6 0.8 6.8 1.9 4.6 0.8 6.8 2.3 3.5 0.8 6.1 1.1 305 9 305 165 -2.8 0.2 -2.1 -3.3 12/23/2006 19:20:00 5.8 0.7 7.6 4.2 5.8 0.7 7.6 3.8 5 0.7 7.2 3 307 8 309 165 -3 0.1 -2.6 -3.3 12/23/2006 19:30:00 5.8 0.9 9.1 4.2 5.7 0.9 8.8 4.2 4.8 0.9 7.6 3 307 7 302 165 -3 0.1 -2.6 -3.3 12/23/2006 19:40:00 6 0.6 7.2 3.8 5.9 0.6 7.2 3.4 5.1 0.9 7.2 2.6 307 6 302 165 -3 0.1 -2.8 -3.3 12/23/2006 19:50:00 6 0.6 7.2 3.8 5.9 0.6 7.2 3.8 5.7 0.6 7.2 4.2 316 5 313 165 -2.9 0.1 -2.6 -3.3 12/23/2006 20:00:00 7.1 0.7 8.8 5.3 6.9 0.7 8.8 5.3 6.7 0.8 8.8 4.6 320 6 326 165 -2.9 0 -2.6 -3 12/23/2006 20:10:00 6.1 0.7 8 4.2 6 0.7 7.6 4.2 5.8 0.7 8 3.4 319 6 314 165 -2.6 0 -2.4 -2.8 12/23/2006 20:20:00 6 1.1 8.8 3.8 5.9 1.1 8.4 3.4 5.7 1 8.4 3.8 316 8 315 165 -2.5 0 -2.1 -2.8 12/23/2006 20:30:00 6.5 0.8 8.4 4.6 6.4 0.8 8.4 4.2 5.9 1 8.4 3.4 310 6 309 165 -2.3 0 -2.1 -2.6 12/23/2006 20:40:00 6.8 0.6 8.4 5.7 6.6 0.5 8 5.3 6.1 0.7 8 4.2 311 5 310 165 -2.6 0 -2.4 -2.8 12/23/2006 20:50:00 7.4 0.7 10.3 6.1 7.3 0.7 10.3 6.1 6 1 9.9 4.2 307 5 312 165 -2.9 0 -2.6 -3 12/23/2006 21:00:00 8.4 1 10.7 6.1 8.2 1 10.3 6.1 7.7 1.1 10.3 5.3 314 6 313 165 -2.7 0.1 -2.6 -2.8 12/23/2006 21:10:00 8.5 0.9 10.7 6.5 8.5 0.8 11.1 6.5 7.7 1.3 10.3 4.2 310 7 315 165 -2.6 0.1 -2.4 -3 12/23/2006 21:20:00 6.4 1.2 9.1 3 6.3 1.2 9.1 3 5.5 1.5 9.9 1.9 307 10 306 165 -2.7 0.2 -2.1 -3 12/23/2006 21:30:00 3.6 1.1 6.1 0.4 3.5 1.2 6.1 0.4 2.2 0.9 5.3 0.7 305 20 312 165 -2.8 0.2 -2.4 -3 12/23/2006 21:40:00 4.2 1 6.5 1.1 4.2 1.1 6.5 0.7 2.9 1.1 5.7 0.4 308 15 306 165 -3 0 -2.8 -3.3 12/23/2006 21:50:00 4.5 0.8 6.8 2.6 4.4 0.9 7.2 2.6 3.3 1 5.7 0.4 301 12 290 165 -3.3 0 -2.8 -3.5 12/23/2006 22:00:00 3.2 1.2 5.7 0.4 3.2 1.2 5.7 0.4 2.5 1 4.9 0.4 297 18 325 165 -3 0 -2.8 -3.3 12/23/2006 22:10:00 3.1 0.6 4.9 1.9 3 0.7 4.6 1.5 2.4 0.7 4.2 0.7 309 15 322 165 -2.9 0 -2.6 -3 12/23/2006 22:20:00 4.3 1 6.8 2.3 4.3 1 6.5 2.3 3.7 1 6.5 1.9 308 8 333 165 -2.7 0 -2.6 -3 12/23/2006 22:30:00 5.4 0.9 7.2 3.4 5.4 0.8 7.2 3.4 4.8 0.8 6.8 2.6 312 7 322 165 -2.7 0.1 -2.6 -3 12/23/2006 22:40:00 5.9 0.6 8 4.2 5.9 0.6 8.4 4.6 5.3 0.5 6.8 3.8 313 6 310 165 -2.8 0.2 -2.4 -3.3 12/23/2006 22:50:00 8 1 10.7 4.9 7.8 1 10.3 4.6 7.1 1 9.1 4.6 311 5 303 165 -3 0.1 -2.8 -3.3 12/23/2006 23:00:00 10 0.7 13 8.4 9.8 0.7 12.6 8.4 9 0.8 11.1 5.7 311 5 307 165 -2.8 0 -2.6 -3 12/23/2006 23:10:00 9.8 1 13 6.8 9.6 1 13 6.8 8.8 1 12.2 5.3 311 7 299 165 -2.6 0.1 -2.1 -2.8 12/23/2006 23:20:00 8.1 1.1 11.5 4.9 8.1 1.1 11.1 4.9 6.8 1.2 11.1 2.6 306 9 296 165 -2.5 0.1 -2.1 -2.8 12/23/2006 23:30:00 7.8 1 10.3 5.3 7.8 1 10.3 5.3 6.9 1 9.9 4.2 310 10 310 165 -2.6 0.1 -2.4 -3 12/23/2006 23:40:00 7.7 0.9 11.1 5.3 7.5 0.9 10.7 5.3 7.2 1 11.1 4.6 317 9 326 165 -2.4 0 -1.9 -2.6 12/23/2006 23:50:00 6.7 0.7 8.8 4.6 6.6 0.7 8.8 4.6 6.5 0.7 8.4 4.6 324 11 339 165 -2.4 0.2 -1.9 -2.6 12/24/2006 00:00:00 7.5 1 10.3 4.9 7.4 1 10.3 4.9 7.2 1 9.9 4.6 316 9 323 165 -2.4 0 -2.1 -2.6 12/24/2006 00:10:00 9.2 1.3 13 6.5 9 1.3 12.6 6.8 8.9 1.5 14.1 5.7 326 10 332 165 -2.5 0.1 -2.1 -2.8 12/24/2006 00:20:00 9.5 1.2 11.5 6.1 9.3 1.1 11.5 6.1 9 1.1 11.8 6.5 323 9 319 165 -2.9 0.1 -2.6 -3 12/24/2006 00:30:00 9 1.4 13.3 5.3 8.3 1.3 12.2 4.6 8.7 1.7 13 4.9 340 12 350 165 -2.5 0.3 -1.9 -3 12/24/2006 00:40:00 7.6 1.8 12.6 2.3 7.4 1.9 13 2.6 7 1.7 10.7 3 337 14 345 165 -2.1 0 -1.9 -2.4 12/24/2006 00:50:00 3.8 0.8 6.1 1.5 3.4 1.1 6.1 1.1 3.4 0.7 4.9 1.5 338 19 351 165 -2.2 0.2 -1.7 -2.8 12/24/2006 01:00:00 5.2 0.7 7.2 3.4 4.7 1 8 1.5 5 0.8 6.8 3 346 12 346 165 -2.6 0.1 -2.4 -2.8 12/24/2006 01:10:00 5.5 0.8 8 3.4 4.4 1.1 7.6 1.9 5.4 0.8 7.2 3.8 354 11 342 165 -2.9 0.2 -2.6 -3.3 12/24/2006 01:20:00 5.8 0.9 9.1 3.8 5.4 1.1 9.1 2.6 5.5 0.8 8.4 3.8 344 8 340 165 -3.5 0.2 -3 -3.9 12/24/2006 01:30:00 5.7 0.5 7.6 4.2 4.9 1 7.2 2.6 5.8 0.5 7.6 4.6 348 7 338 165 -4 0.1 -3.7 -4.4 12/24/2006 01:40:00 6.4 0.9 9.1 4.6 5.9 1.3 9.1 3 6 0.9 9.1 3.8 342 11 319 165 -4.2 0 -3.9 -4.4 12/24/2006 01:50:00 6.7 1.3 9.9 3.8 6.3 1.5 9.9 2.6 6.4 1.2 9.5 4.2 343 12 319 165 -3.3 0.4 -2.8 -4.4 12/24/2006 02:00:00 5.7 0.7 7.6 3.8 4.6 1.3 7.2 2.3 5.6 0.9 8 3 350 12 350 165 -2.9 0 -2.6 -3.3 12/24/2006 02:10:00 6.1 0.9 8.8 3.8 4.5 1.1 8 2.3 5.9 0.8 8.4 3.8 1 8 16 165 -3.3 0.2 -2.8 -3.9 12/24/2006 02:20:00 6.9 0.8 9.1 4.6 4.8 1.2 8.8 3 6.4 0.8 8.8 4.2 358 6 1 165 -4.2 0.2 -3.5 -4.6 12/24/2006 02:30:00 7.2 0.6 8.8 5.3 5.8 1.5 9.1 3 6.8 0.7 9.5 4.6 352 7 359 165 -4.5 0 -4.4 -4.6 12/24/2006 02:40:00 6.9 0.8 9.1 4.9 5 1.2 8 2.6 6.8 0.8 8.8 5.3 2 7 8 165 -4.1 0.1 -3.7 -4.6 12/24/2006 02:50:00 7.9 0.6 9.5 6.1 5.2 1.1 8.4 3.4 7.9 0.7 9.5 6.1 360 6 7 165 -3.9 0 -3.7 -4.4 12/24/2006 03:00:00 7.9 0.5 9.5 6.8 5.8 1.1 8.8 3.8 7.7 0.7 10.3 5.7 356 6 357 165 -4.4 0 -3.9 -4.6 12/24/2006 03:10:00 7.7 0.6 9.5 6.1 6.9 1.2 9.1 3 7.4 0.6 8.8 5.7 348 6 355 165 -4.5 0.1 -4.2 -4.6 12/24/2006 03:20:00 7.2 0.8 9.1 5.3 7 1 9.5 3 6.9 0.8 9.1 4.6 341 9 350 165 -4.4 0.2 -3.9 -4.6 12/24/2006 03:30:00 6.1 1 9.1 4.2 5.6 1.3 9.1 2.6 5.9 0.9 8.8 4.2 349 14 335 165 -4.1 0 -3.7 -4.4 12/24/2006 03:40:00 5.5 0.6 6.8 4.2 5.2 0.8 7.2 2.6 5.5 0.6 6.8 3.8 344 8 355 165 -4.2 0.1 -3.9 -4.6 12/24/2006 03:50:00 6.2 0.8 9.1 4.2 4.6 1 7.2 2.6 6.2 0.8 9.5 4.6 358 8 3 165 -4.1 0.1 -3.9 -4.4 12/24/2006 04:00:00 9.1 1.9 14.1 5.3 7.6 2.2 13.7 3.8 9.1 2 14.1 4.9 357 15 10 165 -3.8 0.3 -3.3 -4.4 12/24/2006 04:10:00 8.4 1.2 12.6 5.7 7.1 1.5 12.2 3.4 8.4 1.3 12.6 5.7 351 13 15 165 -3.5 0.1 -3.3 -3.9 12/24/2006 04:20:00 9.9 1.3 13.7 6.5 8.2 1.7 12.2 4.9 9.9 1.5 14.5 6.8 351 10 353 165 -3.9 0.2 -3.3 -4.2 12/24/2006 04:30:00 7.2 1.4 12.6 4.6 6.5 1.2 11.1 3.4 7 1.5 12.2 3.8 338 15 0 165 -3.9 0.3 -3.3 -4.4 12/24/2006 04:40:00 7.5 1.1 11.8 3.4 6.8 1.4 11.8 3.8 6.7 1.5 9.9 3 338 22 310 165 -4.3 0.1 -3.9 -4.6 12/24/2006 04:50:00 9.7 1.5 13.7 7.2 9.4 1.7 14.1 5.3 9.4 1.5 13.7 6.5 337 11 329 165 -4.3 0.1 -3.9 -4.6 12/24/2006 05:00:00 10 1.2 13.3 7.2 9.9 1.4 13.3 6.5 9.8 1.2 13.3 6.5 339 9 338 165 -4 0.1 -3.7 -4.4 12/24/2006 05:10:00 9.7 1.3 13 6.8 9.6 1.5 13.3 4.9 9.4 1.5 13 5.7 335 9 340 165 -4.2 0 -3.9 -4.6 12/24/2006 05:20:00 8.5 1 11.8 6.5 8.4 1.1 11.8 4.2 8.3 1 11.8 6.1 337 8 335 165 -4.3 0 -4.2 -4.6 12/24/2006 05:30:00 9.7 1.2 12.2 6.8 9.3 1.5 12.6 5.3 9.2 1.2 12.6 6.5 344 8 347 165 -4.3 0 -3.9 -4.6 12/24/2006 05:40:00 8.9 1.5 13.7 5.3 8.7 1.7 13.7 4.6 8.4 1.7 14.5 4.2 337 10 360 165 -4.2 0 -3.9 -4.4 12/24/2006 05:50:00 9.1 1.5 13 5.3 8.6 1.7 13.3 4.9 8.5 1.7 13.3 4.6 339 11 330 165 -4.2 0 -3.9 -4.4 12/24/2006 06:00:00 9.3 1.7 13.3 5.3 8.9 1.8 14.1 5.3 8.9 1.7 15.6 4.9 332 14 316 165 -4 0 -3.7 -4.2 12/24/2006 06:10:00 11.1 1.6 15.6 7.2 11 1.7 15.6 7.2 10.7 1.6 14.9 6.1 334 12 338 165 -3.8 0.1 -3.5 -4.2 12/24/2006 06:20:00 10.2 1.5 13.7 7.2 10.1 1.5 14.1 5.7 9.7 1.7 15.3 5.3 331 11 338 165 -3.7 0 -3.5 -3.9 12/24/2006 06:30:00 9.2 1.5 13 4.6 8.4 1.9 13.7 3.4 9 1.5 12.6 4.6 337 15 346 165 -3.7 0 -3.5 -3.9 12/24/2006 06:40:00 12.2 1.9 17.9 8.4 11.3 2.5 19.1 6.1 11.9 2 17.2 7.6 343 12 343 165 -3.7 0.1 -3.3 -3.9 12/24/2006 06:50:00 8.9 1.6 14.9 4.9 8.2 2 14.1 3.4 8.7 1.5 14.5 5.7 343 13 356 165 -3.7 0 -3.5 -3.9 12/24/2006 07:00:00 10.9 1.8 16.1 6.8 9.7 2.2 16.1 5.3 10.6 1.9 15.6 6.1 345 13 342 165 -3.8 0 -3.5 -3.9 12/24/2006 07:10:00 12.8 1.7 16.8 8.8 12.3 2.4 17.2 5.3 12.6 2 17.6 7.6 340 12 338 165 -3.8 0.1 -3.5 -3.9 12/24/2006 07:20:00 12.2 2 17.2 8.4 11.7 2.1 17.2 7.2 12.1 2.1 18.3 7.6 339 11 356 165 -3.5 0.1 -3.3 -3.7 12/24/2006 07:30:00 11.2 1.3 14.9 7.6 10.8 1.4 14.1 6.8 10.9 1.3 14.1 7.6 334 15 1 165 -3.6 0 -3.3 -3.7 12/24/2006 07:40:00 13.3 1.8 18.3 9.9 12.2 2.3 17.6 5.7 13 1.9 16.8 8.8 345 14 344 165 -3.3 0 -3 -3.5 12/24/2006 07:50:00 13.4 2.2 18.7 8 11.9 2.4 18.3 6.5 13.2 2.5 18.7 7.6 350 15 20 165 -3.1 0 -2.8 -3.3 12/24/2006 08:00:00 12.3 2.3 17.6 6.8 11.3 2.4 17.2 5.3 12.2 2.2 16.8 7.2 343 14 15 165 -3.2 0 -3 -3.3 12/24/2006 08:10:00 12.5 2.1 17.9 7.6 11.3 2 17.6 6.8 12.4 2.1 17.6 8 343 15 358 165 -3.1 0 -2.8 -3.3 12/24/2006 08:20:00 11.7 1.5 16.8 7.6 11.1 1.7 16.8 6.5 11.3 1.6 16.4 8 342 11 350 165 -3.2 0 -2.8 -3.5 12/24/2006 08:30:00 13.1 2 17.6 8.8 12.3 2.1 17.6 6.8 12.9 2.1 18.7 8 338 12 351 165 -3.1 0.1 -2.8 -3.5 12/24/2006 08:40:00 14.3 2.1 19.5 9.1 13.7 2.5 20.2 7.6 14.1 2.1 21.4 9.1 339 12 337 165 -3 0 -2.8 -3.3 12/24/2006 08:50:00 13.1 2 17.6 6.5 12.9 2 17.9 6.5 12.7 2.1 17.6 6.1 328 11 314 165 -3 0 -2.8 -3.3 12/24/2006 09:00:00 14 2.4 21.4 9.1 14 2.5 21 8.8 13.7 2.6 21.8 7.2 325 12 310 165 -2.9 0 -2.6 -3 12/24/2006 09:10:00 17.6 2.3 23.7 12.6 17.5 2.3 23.3 12.2 17.3 2.6 24.4 11.8 322 11 325 165 -2.8 0 -2.6 -3 12/24/2006 09:20:00 18.7 2.8 25.2 11.5 18.5 2.8 25.6 11.8 18.2 2.9 25.6 9.1 328 10 337 165 -2.8 0 -2.8 -3 12/24/2006 09:30:00 19.3 2.4 24 13.3 19 2.3 24.8 13 19.1 2.5 24.4 13 327 9 323 165 -2.8 0 -2.6 -3 12/24/2006 09:40:00 18.3 2.4 26.3 12.2 18.1 2.3 26 13 18.1 2.5 26.8 11.1 328 9 325 165 -2.9 0 -2.8 -3 12/24/2006 09:50:00 20.1 2.7 26.8 14.5 19.6 2.8 26.3 13 20 2.8 26.8 13.7 328 11 325 165 -2.8 0 -2.6 -3 12/24/2006 10:00:00 18 2.8 26 11.5 17.8 2.9 26.3 8.4 17.4 2.9 26.8 9.9 325 11 310 165 -2.8 0 -2.6 -3 12/24/2006 10:10:00 16.1 2.6 24.8 10.3 15.8 2.8 25.6 8 15.6 2.8 24 8 325 14 339 165 -2.8 0 -2.6 -2.8 12/24/2006 10:20:00 15.4 2.4 22.1 9.1 15.2 2.3 22.1 9.9 14.9 2.6 23.3 9.1 325 10 306 165 -2.6 0 -2.6 -2.8 12/24/2006 10:30:00 14.5 2.6 21 8.4 14.3 2.6 21.8 7.6 14.1 2.6 21.4 8.8 327 13 311 165 -2.6 0 -2.6 -2.8 12/24/2006 10:40:00 14.3 2.5 20.6 8.4 14.2 2.6 20.6 6.8 13.2 2.7 19.5 6.5 320 17 319 165 -2.5 0 -2.6 -2.8 12/24/2006 10:50:00 16.2 2.7 23.3 9.1 15.8 3.1 23.7 7.6 15.9 2.7 22.9 9.5 332 14 341 165 -2.5 0 -2.4 -2.6 12/24/2006 11:00:00 15.4 2.2 21 9.5 15.3 2.2 20.6 9.9 14.6 2.5 20.2 9.1 326 12 338 165 -2.5 0 -1.9 -2.6 12/24/2006 11:10:00 13.8 2.4 21.4 8.8 13.5 2.5 21 7.6 13.3 2.4 21 8.8 324 13 321 165 -2.4 0 -2.1 -2.6 12/24/2006 11:20:00 12.5 1.9 21 7.2 12.3 2 22.1 7.2 12.1 2.1 22.6 8 326 12 324 165 -2.4 0 -2.1 -2.6 12/24/2006 11:30:00 12.7 1.9 17.6 8.4 12.4 2 17.6 7.2 11.8 2 16.4 7.2 328 12 321 165 -2.4 0 -2.1 -2.6 12/24/2006 11:40:00 15.6 2.5 21.8 9.5 15.4 2.5 21.8 9.1 15 2.8 22.9 7.2 322 10 332 165 -2.2 0 -2.1 -2.6 12/24/2006 11:50:00 15.4 2.6 22.9 9.9 15.2 2.8 23.3 7.6 15.1 2.7 22.1 9.9 330 10 330 165 -2.4 0 -2.1 -2.6 12/24/2006 12:00:00 15.7 2.6 22.6 10.3 15.7 2.6 22.6 10.3 15.6 2.8 23.3 9.9 324 10 327 165 -2.5 0 -1.9 -2.6 12/24/2006 12:10:00 16.8 2.6 25.2 10.7 16.5 2.9 25.6 8.4 16.6 2.8 26 9.5 331 13 325 165 -2.5 0 -2.1 -2.6 12/24/2006 12:20:00 18.4 2.2 24.8 12.2 18.1 2.5 24.8 10.3 18.3 2.3 24.8 11.8 334 9 348 165 -2.2 0 -2.1 -2.6 12/24/2006 12:30:00 18.4 2.7 25.2 10.7 18.2 2.8 25.2 10.3 18 2.7 25.2 10.3 333 9 333 165 -2.1 0 -1.9 -2.1 12/24/2006 12:40:00 17.6 2.8 24.4 10.7 17.4 2.8 24.4 10.3 17.4 3.2 25.6 10.3 329 11 331 165 -2.1 0 -1.9 -2.4 12/24/2006 12:50:00 19.6 2.6 27.1 13 19.5 2.8 26.3 10.3 19.4 2.7 26.8 12.2 332 10 335 165 -2.1 0 -1.9 -2.4 12/24/2006 13:00:00 20.5 2.2 27.5 14.1 20.2 2.3 26.8 13 20.4 2.3 27.1 13.7 334 9 335 165 -2.1 0 -1.7 -2.4 12/24/2006 13:10:00 19.3 2.6 26.3 10.3 19 2.6 25.6 9.9 19 2.8 24.4 11.5 334 8 331 165 -2.1 0 -1.9 -2.1 12/24/2006 13:20:00 17.6 2.2 22.9 12.2 17.5 2.2 22.9 11.8 17.3 2.4 23.7 10.3 331 9 323 165 -2.1 0 -1.9 -2.4 12/24/2006 13:30:00 16.9 2.7 24.8 9.1 16.6 2.7 24.8 7.6 16.6 2.7 23.7 8 328 13 314 165 -2.2 0 -2.1 -2.4 12/24/2006 13:40:00 20.5 2.9 26.8 12.6 20 3.2 26.8 9.9 20.1 2.9 26 13 335 10 345 165 -2.1 0 -1.9 -2.4 12/24/2006 13:50:00 20.3 3.1 26.3 12.2 20.1 3.1 26.3 13 19.8 3.3 26.8 9.9 334 10 347 165 -2.1 0 -1.9 -2.1 12/24/2006 14:00:00 21.6 2.8 29.1 14.5 21.2 3.1 30.2 8.4 21.5 2.9 30.2 14.1 338 10 351 165 -2.1 0 -1.9 -2.1 12/24/2006 14:10:00 21.1 2.8 27.1 12.6 20.3 3.2 27.1 11.8 20.8 2.9 28.3 10.7 339 10 333 165 -2.1 0 -1.9 -2.1 12/24/2006 14:20:00 21.5 2.7 30.9 14.9 21 2.7 27.9 14.9 21.2 2.8 30.2 13.7 338 8 350 165 -2 0 -1.7 -2.1 12/24/2006 14:30:00 21.1 2.9 26.8 13.7 20.9 3.2 27.1 10.7 20.7 3.1 26.3 13.7 338 8 348 165 -2 0 -1.9 -2.1 12/24/2006 14:40:00 20.7 3.1 30.6 12.2 20.3 3.3 31.3 11.5 20.7 3.1 29.8 11.5 337 10 335 165 -2 0 -1.7 -2.1 12/24/2006 14:50:00 19.3 2.5 25.6 11.5 19 2.5 26 10.3 18.9 2.5 24.4 12.2 332 12 332 165 -2 0 -1.9 -2.1 12/24/2006 15:00:00 20 2.3 26.8 14.5 19.2 2.7 26.3 10.7 19.8 2.4 26.8 14.5 340 9 353 165 -2 0 -1.9 -2.1 12/24/2006 15:10:00 21.4 2.8 28.3 12.6 21.2 3.1 28.3 12.6 21.1 2.9 27.1 13 339 9 2 165 -2 0 -1.9 -2.1 12/24/2006 15:20:00 18.4 2.8 25.6 10.7 17.8 3.1 24.8 9.5 18.6 2.9 25.2 11.1 338 10 329 165 -2.1 0 -1.9 -2.1 12/24/2006 15:30:00 19.6 3.3 28.3 9.1 19.1 3.8 27.9 8.4 19.4 3.2 26.3 10.3 334 12 321 165 -2.2 0 -1.9 -2.4 12/24/2006 15:40:00 20.6 2.9 28.3 12.6 20.2 3.2 29.8 12.2 20.3 2.9 28.7 13.3 336 9 339 165 -2.2 0 -2.1 -2.6 12/24/2006 15:50:00 20.3 2.5 26 14.1 20.1 2.8 26.8 11.8 20 2.7 26 13 338 9 335 165 -2.3 0 -2.1 -2.6 12/24/2006 16:00:00 17.5 2.8 25.2 11.1 17 3.1 24.8 9.9 17 2.9 24.4 11.1 338 10 330 165 -2.5 0.1 -2.1 -2.6 12/24/2006 16:10:00 19.7 2.8 26.3 11.8 19.7 2.9 27.1 11.8 19.6 2.8 26.8 13.7 338 8 340 165 -2.5 0 -2.4 -2.6 12/24/2006 16:20:00 16.2 3.3 23.7 9.9 15.1 3.5 22.9 7.2 16.1 3.3 24 10.3 340 12 354 165 -2.5 0 -2.4 -2.8 12/24/2006 16:30:00 16.6 2.8 23.3 9.9 15.7 2.5 22.9 9.9 16.3 3.1 24.8 9.5 338 12 351 165 -2.6 0 -2.6 -2.8 12/24/2006 16:40:00 14.3 1.9 19.1 9.5 13.9 1.8 17.9 8.8 14 2.1 19.1 8.8 329 13 352 165 -2.9 0 -2.6 -3 12/24/2006 16:50:00 14.6 1.8 19.9 9.5 14.3 2 19.9 8 14.1 1.9 19.5 8.8 332 13 344 165 -3 0.1 -2.8 -3.3 12/24/2006 17:00:00 14.8 2.6 21.8 9.9 14.4 2.6 21.8 9.1 14.2 2.6 21 9.1 329 15 326 165 -3.1 0 -2.8 -3.3 12/24/2006 17:10:00 15.6 2.8 22.6 9.5 15.2 2.9 22.6 8.8 15.2 2.8 22.6 9.9 335 12 345 165 -3.1 0 -2.8 -3.3 12/24/2006 17:20:00 16.4 2.2 22.9 11.1 16 2.4 22.6 9.5 16.2 2.5 21.8 8.8 332 13 333 165 -3.1 0 -2.8 -3.3 12/24/2006 17:30:00 16.4 1.8 20.6 10.7 15.8 2.1 20.6 9.5 16.1 1.9 23.3 10.3 332 14 316 165 -3.2 0 -3 -3.3 12/24/2006 17:40:00 15.8 2.4 21 9.1 15.4 2.3 20.6 9.1 15.2 2.3 21.4 9.5 329 15 343 165 -3.2 0 -3 -3.5 12/24/2006 17:50:00 15.5 2.1 21 10.3 15.2 2 19.9 9.9 15.2 2.1 20.6 10.3 328 16 344 165 -3.3 0 -3 -3.5 12/24/2006 18:00:00 15.6 1.8 21 11.5 15.4 1.8 21.8 10.7 15 1.7 20.2 10.7 323 15 313 165 -3.4 0 -3 -3.5 12/24/2006 18:10:00 17.5 2.5 24.8 11.5 17.4 2.5 24.4 11.1 16.1 2.3 22.1 11.1 312 17 295 165 -3.2 0.1 -3 -3.5 12/24/2006 18:20:00 15.5 1.6 19.5 11.5 15.3 1.7 19.9 9.9 14.7 1.7 19.1 9.1 322 15 300 165 -3.4 0 -3 -3.5 12/24/2006 18:30:00 16.3 2.3 22.1 11.5 16.1 2.3 21.8 9.5 15.9 2.4 22.6 9.9 326 15 341 165 -3.3 0 -3 -3.5 12/24/2006 18:40:00 15.6 2.3 21.8 9.5 15.6 2.3 22.6 9.9 14.6 2.7 20.6 7.2 314 16 324 165 -3.3 0 -3 -3.5 12/24/2006 18:50:00 16.3 1.8 21.4 11.8 16.1 1.8 21 11.8 15.4 1.9 20.2 10.3 317 14 296 165 -3.3 0.1 -3 -3.5 12/24/2006 19:00:00 15.6 2.1 20.6 9.1 15.5 2 20.6 9.5 14.5 2.2 19.5 9.1 317 14 301 165 -3.3 0 -3 -3.5 12/24/2006 19:10:00 16.5 2.3 26.3 10.3 16.3 2.4 26 8.8 15.9 2.1 21.8 11.5 319 15 319 165 -3.2 0 -2.8 -3.3 12/24/2006 19:20:00 18.2 2.4 24 11.1 17.9 2.6 24 9.1 17.4 2.6 23.3 10.7 318 15 304 165 -3 0 -2.6 -3.3 12/24/2006 19:30:00 17.3 2.2 26 11.5 17.2 2.3 26.3 10.7 16.5 2.2 22.1 9.9 315 12 303 165 -2.9 0.1 -2.6 -3.3 12/24/2006 19:40:00 17.3 2.3 24.4 9.5 17.3 2.3 24.8 9.5 16.5 2.2 22.1 8.4 314 12 301 165 -3 0 -2.8 -3.3 12/24/2006 19:50:00 19.2 2.8 27.5 11.1 19.1 2.8 28.7 10.7 17.7 2.6 24.8 9.5 314 16 297 165 -2.9 0 -2.6 -3 12/24/2006 20:00:00 20.7 2.7 29.1 14.5 20.6 2.8 29.8 14.5 19.9 2.8 27.5 12.6 317 12 290 165 -2.7 0.1 -2.6 -3 12/24/2006 20:10:00 20.3 2.5 27.9 13.3 20.2 2.5 28.3 13 19.5 2.3 25.2 12.6 317 12 323 165 -2.6 0 -2.4 -2.8 12/24/2006 20:20:00 18.3 1.7 23.7 12.2 18.1 1.7 23.3 12.2 17.9 1.8 24 13 320 11 336 165 -2.9 0.1 -2.6 -3 12/24/2006 20:30:00 17.9 1.8 24 13.3 17.8 1.7 23.7 13.3 17.5 1.9 23.7 12.6 318 9 295 165 -2.9 0 -2.6 -3.3 12/24/2006 20:40:00 18.8 2 24.8 13.3 18.6 2 24 13.7 18.2 1.9 22.6 13.3 318 9 305 165 -2.9 0 -2.6 -3 12/24/2006 20:50:00 18.1 1.8 26 13.3 17.9 1.8 26 13.7 17.7 2 26.8 12.6 318 9 316 165 -3 0 -2.6 -3.3 12/24/2006 21:00:00 18.7 1.8 24.4 14.1 18.5 1.7 24 14.5 18.4 1.8 23.7 14.1 318 8 313 165 -2.8 0 -2.6 -3 12/24/2006 21:10:00 18.4 1.4 23.3 15.3 18.1 1.4 22.9 14.9 17.9 1.6 23.3 13.3 317 7 316 165 -2.8 0 -2.6 -3 12/24/2006 21:20:00 19.2 1.6 25.2 13.3 19 1.7 24.8 13.3 18.3 1.8 24.8 13.3 312 7 309 165 -2.6 0 -2.4 -2.8 12/24/2006 21:30:00 20.4 1.8 24.8 14.5 20.1 1.8 24.8 14.1 19.8 1.9 24 13.3 313 8 310 165 -2.5 0.1 -2.1 -2.8 12/24/2006 21:40:00 22.1 1.7 27.5 17.2 21.8 1.7 27.1 16.8 21.7 1.7 26.8 16.4 314 6 323 165 -2.7 0 -2.6 -2.8 12/24/2006 21:50:00 22.1 1.9 28.3 17.2 21.9 1.8 28.3 17.2 21.4 2.1 27.9 16.4 313 8 303 165 -2.6 0 -2.4 -2.8 12/24/2006 22:00:00 23.4 1.4 27.9 19.1 23.2 1.4 27.5 19.1 22.8 1.5 26.8 17.9 311 6 317 165 -2.5 0 -2.4 -2.8 12/24/2006 22:10:00 25.5 2.1 30.6 19.9 25.3 2 30.6 19.9 24.7 2.3 30.2 17.2 310 7 309 165 -2.5 0.1 -2.1 -2.8 12/24/2006 22:20:00 25.7 1.9 30.2 21 25.6 1.8 30.2 20.6 25.2 1.8 28.7 20.2 311 7 308 165 -2.3 0 -1.9 -2.6 12/24/2006 22:30:00 24.4 1.7 28.7 18.7 24.1 1.7 27.9 18.3 23.9 1.7 28.7 18.3 312 6 298 165 -2.5 0.1 -2.1 -2.6 12/24/2006 22:40:00 24 1.5 29.1 19.1 23.7 1.5 28.3 19.5 23.6 1.7 28.7 19.1 313 6 301 165 -2.5 0 -2.1 -2.6 12/24/2006 22:50:00 23.7 1.5 27.1 19.5 23.5 1.4 27.1 19.1 23 1.5 27.5 18.3 311 6 310 165 -2.5 0 -2.4 -2.8 12/24/2006 23:00:00 24 1.7 28.7 19.5 23.8 1.7 27.9 19.5 23.4 1.9 29.1 17.6 311 7 318 165 -2.5 0 -2.1 -2.6 12/24/2006 23:10:00 23.6 1.6 27.5 18.3 23.3 1.5 27.1 17.9 22.8 1.5 26.8 17.6 311 6 307 165 -2.5 0 -2.4 -2.8 12/24/2006 23:20:00 24.2 1.9 29.1 17.9 23.9 1.8 29.1 17.9 23.5 1.9 27.9 17.6 312 7 295 165 -2.4 0.1 -1.9 -2.8 12/24/2006 23:30:00 24.3 1.9 28.3 18.3 24 1.8 28.3 17.2 23.6 1.9 29.1 18.3 310 6 315 165 -2.5 0 -2.1 -2.8 12/24/2006 23:40:00 24.6 1.7 28.3 19.1 24.4 1.7 27.9 19.1 23.5 2 28.3 16.8 309 7 307 165 -2.4 0.1 -1.9 -2.6 12/24/2006 23:50:00 23.9 1.7 28.3 19.1 23.6 1.7 27.9 18.7 23 2 27.5 17.9 310 7 312 165 -2.5 0 -2.1 -2.6 12/25/2006 00:00:00 23.3 1.6 26.8 19.5 23.1 1.5 26.3 19.1 22 1.9 26 16.4 309 8 307 165 -2.5 0 -2.6 -2.8 12/25/2006 00:10:00 24.6 1.6 27.9 18.3 24.3 1.6 27.9 17.9 23.8 1.9 27.5 17.2 310 6 314 165 -2.5 0 -2.1 -2.8 12/25/2006 00:20:00 25 1.7 29.4 19.9 24.8 1.7 29.1 19.9 24.3 1.8 28.7 19.1 310 5 307 165 -2.5 0 -2.4 -2.8 12/25/2006 00:30:00 25 1.7 29.4 20.2 24.8 1.6 29.1 20.2 23.6 2 29.4 17.2 308 6 296 165 -2.5 0 -2.1 -2.8 12/25/2006 00:40:00 24.9 1.5 28.3 19.5 24.7 1.4 27.9 19.1 23.9 1.5 27.1 20.2 309 6 312 165 -2.5 0 -2.1 -2.6 12/25/2006 00:50:00 24.1 1.5 27.1 19.9 23.8 1.4 26.8 19.9 22.9 1.7 27.1 17.9 310 6 314 165 -2.5 0 -2.4 -2.8 12/25/2006 01:00:00 23.9 1.4 27.9 19.9 23.7 1.4 27.1 19.5 22.7 1.6 27.5 17.2 309 6 316 165 -2.6 0 -2.6 -2.8 12/25/2006 01:10:00 23.3 1.3 28.3 19.9 23 1.3 28.3 19.9 22.6 1.4 27.9 18.3 311 5 316 165 -2.6 0 -2.4 -2.8 12/25/2006 01:20:00 23.5 1.7 27.1 17.9 23.3 1.6 27.1 17.6 22.3 1.7 26.3 16.4 310 7 294 165 -2.7 0 -2.6 -2.8 12/25/2006 01:30:00 24.5 1.6 29.8 19.9 24.3 1.6 29.4 19.5 23.4 1.9 30.2 16.4 309 7 313 165 -2.5 0.1 -2.1 -2.8 12/25/2006 01:40:00 23.5 1.7 27.9 19.5 23.2 1.6 27.5 18.7 22.5 1.7 26.8 16.4 310 7 310 165 -2.6 0 -2.6 -2.8 12/25/2006 01:50:00 23.8 1.6 28.3 17.6 23.5 1.5 27.5 18.7 21.9 1.7 25.2 16.8 307 6 301 165 -2.8 0 -2.6 -3 12/25/2006 02:00:00 22.9 1.3 26 19.1 22.6 1.3 25.6 18.7 21.4 1.7 25.2 16.4 309 6 307 165 -2.9 0 -2.8 -3.3 12/25/2006 02:10:00 23.2 1.5 26.3 19.5 22.9 1.4 25.6 19.5 21 1.7 25.2 16.1 307 6 310 165 -2.9 0 -2.6 -3 12/25/2006 02:20:00 23.2 1.3 27.1 19.1 22.9 1.3 26.8 18.7 20.9 1.5 26.3 16.4 307 6 307 165 -2.9 0.1 -2.6 -3.3 12/25/2006 02:30:00 23 1.2 27.1 19.1 22.7 1.2 26.8 18.7 20.7 1.3 24.8 16.8 307 5 304 165 -3.1 0 -2.8 -3.3 12/25/2006 02:40:00 23.3 1.5 26.3 18.3 22.9 1.5 26 18.3 21.7 2 26.3 16.8 308 5 307 165 -3.1 0 -2.8 -3.3 12/25/2006 02:50:00 22.8 1.5 26 18.7 22.5 1.5 25.6 18.3 22.2 1.7 26.8 14.9 311 6 316 165 -3.1 0 -2.8 -3.3 12/25/2006 03:00:00 23.5 1.3 27.1 20.2 23.3 1.3 27.1 19.9 23 1.4 26.3 18.7 311 7 317 165 -3.1 0 -2.8 -3.3 12/25/2006 03:10:00 24.2 1.7 28.3 18.7 23.9 1.7 28.3 19.1 23.3 2.1 29.1 16.4 310 7 309 165 -3.3 0 -3 -3.5 12/25/2006 03:20:00 24.1 1.7 27.9 19.5 23.9 1.7 27.9 19.5 23.9 2 28.7 18.3 313 6 313 165 -3.4 0 -3.3 -3.5 12/25/2006 03:30:00 25.6 1.7 29.1 18.3 25.3 1.6 29.1 18.3 25 1.9 29.8 18.3 310 6 311 165 -3.4 0 -3.3 -3.5 12/25/2006 03:40:00 24 1.8 27.5 17.9 23.7 1.7 27.1 17.9 23.3 2.2 27.5 16.8 309 7 310 165 -3.7 0 -3.5 -3.9 12/25/2006 03:50:00 25 1.3 27.5 20.6 24.8 1.3 27.5 20.6 24.1 1.9 29.4 17.9 309 6 313 165 -3.7 0 -3.5 -3.9 12/25/2006 04:00:00 24.5 1.7 28.7 17.9 24.3 1.7 27.9 17.9 23.4 2 27.9 17.6 307 7 293 165 -3.8 0 -3.5 -3.9 12/25/2006 04:10:00 22.4 1.7 25.6 17.6 22.2 1.6 25.2 16.8 20.8 2 25.6 13.3 306 8 297 165 -3.9 0 -3.7 -4.2 12/25/2006 04:20:00 21.2 2 24.8 16.4 21 1.9 24.4 16.1 19.8 2.3 24.8 11.5 307 9 313 165 -3.9 0 -3.7 -4.2 12/25/2006 04:30:00 21.2 2 26.8 15.6 21.1 2 26.8 16.4 19.9 2.2 24 13.3 309 7 312 165 -3.9 0.1 -3.5 -4.2 12/25/2006 04:40:00 19.7 1.8 24.4 15.3 19.5 1.7 24 15.6 18.6 1.8 22.9 14.1 309 7 305 165 -3.8 0 -3.5 -3.9 12/25/2006 04:50:00 20.7 1.5 25.6 15.6 20.5 1.5 25.6 15.6 19.5 1.9 24 11.5 310 8 306 165 -3.8 0 -3.5 -3.9 12/25/2006 05:00:00 18.9 1.5 22.6 14.5 18.7 1.5 22.6 14.5 18.1 1.7 23.3 13.7 310 7 316 165 -3.9 0 -3.5 -4.2 12/25/2006 05:10:00 19.6 1.9 24.8 14.5 19.3 1.9 25.2 14.5 18.5 2.1 24.4 12.6 309 9 298 165 -3.8 0 -3.5 -3.9 12/25/2006 05:20:00 19.1 2 23.7 14.1 18.8 2 22.9 14.1 18 2 23.3 13 311 10 300 165 -3.7 0.1 -3.5 -3.9 12/25/2006 05:30:00 19.5 2 24.4 14.5 19.3 2 24 14.1 18.4 2.4 24.4 11.8 311 9 321 165 -3.8 0 -3.5 -3.9 12/25/2006 05:40:00 22 1.8 25.6 16.1 21.7 1.8 25.6 15.6 21.4 2.1 27.1 13 313 6 323 165 -3.6 0.1 -3.3 -3.9 12/25/2006 05:50:00 22 1.8 26 14.9 21.7 1.8 25.2 14.5 21.5 2.1 26 14.9 313 6 313 165 -3.6 0.1 -3.3 -3.7 12/25/2006 06:00:00 21.1 1.7 25.6 16.1 20.9 1.7 25.2 16.1 20.5 1.9 24 15.3 311 7 313 165 -3.7 0 -3.5 -3.9 12/25/2006 06:10:00 22 1.5 24.8 17.2 21.8 1.5 24.8 16.8 21.5 1.7 25.6 14.1 312 7 310 165 -3.8 0 -3.5 -3.9 12/25/2006 06:20:00 22.2 2 27.1 16.8 22 2 27.1 16.8 21.7 2.5 28.7 15.3 311 8 310 165 -4 0.1 -3.7 -4.4 12/25/2006 06:30:00 21.5 1.8 26.8 17.2 21.3 1.8 26.3 16.8 20.5 2.3 26.8 15.3 308 8 302 165 -4.1 0 -3.9 -4.4 12/25/2006 06:40:00 20.5 1.9 26 15.6 20.2 1.8 26 16.1 20.1 2.2 26 15.3 314 8 319 165 -4.1 0 -3.9 -4.4 12/25/2006 06:50:00 20.8 2.1 27.5 15.3 20.6 2.1 26.8 15.6 20.3 2.4 26 14.1 314 7 316 165 -4.2 0 -3.9 -4.4 12/25/2006 07:00:00 22.8 2 27.1 18.3 22.6 1.9 27.1 18.3 22.5 2.2 27.5 16.8 312 7 312 165 -4.3 0 -3.9 -4.6 12/25/2006 07:10:00 21.3 1.7 26 16.8 21.1 1.7 25.2 16.8 20.3 2.1 25.2 14.9 309 8 298 165 -4.5 0.1 -4.4 -4.6 12/25/2006 07:20:00 20.4 1.8 25.2 14.1 20.2 1.8 24.8 14.1 18.8 2 25.6 14.9 306 9 299 165 -4.7 0 -4.4 -4.8 12/25/2006 07:30:00 21 1.7 26 15.6 20.8 1.7 25.6 15.6 18.4 1.7 23.3 14.9 305 8 302 165 -4.8 0 -4.6 -5 12/25/2006 07:40:00 23 1.9 26.8 18.3 22.7 1.8 26.3 18.3 18.8 1.7 24 14.1 299 8 297 165 -4.8 0 -4.6 -5 12/25/2006 07:50:00 22.7 1.9 26.3 17.9 22.4 1.8 26 17.9 18.2 1.8 24 13 298 8 293 165 -4.8 0 -4.6 -5 12/25/2006 08:00:00 22.6 1.8 26.3 16.8 22.4 1.7 26 17.2 18.5 1.9 25.6 12.6 299 7 294 165 -4.8 0 -4.6 -5 12/25/2006 08:10:00 23.1 1.8 27.1 18.3 22.8 1.7 26.8 18.3 18.8 1.9 24.4 13.3 296 9 300 165 -4.7 0 -4.4 -4.8 12/25/2006 08:20:00 21.6 1.8 26 17.6 21.3 1.7 25.6 17.2 17.6 2.2 23.7 13 297 8 298 165 -4.8 0 -4.6 -5 12/25/2006 08:30:00 23.9 1.9 27.9 18.3 23.5 1.8 27.5 17.9 19.7 2.2 26 14.5 298 7 279 165 -4.9 0 -4.6 -5.3 12/25/2006 08:40:00 24 1.9 28.3 17.9 23.7 1.8 27.5 18.3 19.8 2.3 26 14.1 298 9 302 165 -5 0 -4.8 -5.3 12/25/2006 08:50:00 23.3 1.6 27.5 17.2 23 1.7 27.1 17.9 19.5 2.1 25.2 13 298 9 302 165 -5 0 -4.8 -5.3 12/25/2006 09:00:00 23.4 1.9 27.9 17.6 23.2 1.9 27.5 18.3 19.4 2.2 26.3 13.7 297 9 300 165 -5.1 0 -4.8 -5.3 12/25/2006 09:10:00 25.9 1.8 29.8 20.2 25.6 1.8 29.8 19.9 21.9 2.3 29.4 16.4 298 9 298 165 -5.1 0 -4.8 -5.3 12/25/2006 09:20:00 25.6 1.8 29.4 20.6 25.3 1.8 29.4 19.9 21.5 2.4 27.9 14.9 298 9 298 165 -5.2 0 -5 -5.5 12/25/2006 09:30:00 25.1 2 29.8 19.1 24.8 2 29.4 18.3 21.1 2.5 28.3 14.5 298 10 305 165 -5.3 0 -5 -5.5 12/25/2006 09:40:00 25.1 1.9 29.1 18.3 24.8 1.9 28.7 17.9 21.4 2.2 26.3 15.6 299 9 301 165 -5.2 0 -5 -5.5 12/25/2006 09:50:00 24.4 1.7 29.4 17.6 24.1 1.7 29.1 17.6 20.9 2 26.3 16.1 299 8 301 165 -5.3 0.1 -5 -5.5 12/25/2006 10:00:00 24.5 1.5 27.5 18.3 24.2 1.5 27.5 18.7 20.4 2 26 14.5 297 9 306 165 -5.2 0 -4.8 -5.5 12/25/2006 10:10:00 24.3 1.9 29.4 18.3 24 1.8 28.7 18.7 21.1 2.5 26.3 15.6 300 9 292 165 -5 0 -4.6 -5.3 12/25/2006 10:20:00 25.5 2.1 30.2 18.3 25.1 2 29.8 17.9 22.3 2.2 27.9 15.3 300 9 300 165 -4.9 0 -4.6 -5 12/25/2006 10:30:00 25.6 2.1 30.2 20.6 25.3 2 29.4 20.6 23.2 2.8 31.8 16.4 302 10 301 165 -4.9 0 -4.6 -5 12/25/2006 10:40:00 24.4 2.5 30.2 15.6 24.2 2.4 29.8 16.1 22.2 2.8 29.4 14.1 302 10 309 165 -4.9 0 -4.6 -5 12/25/2006 10:50:00 24.5 2.2 29.1 17.9 24.2 2.2 28.7 18.3 22.5 2.4 27.9 16.1 303 9 301 165 -4.9 0 -4.6 -5 12/25/2006 11:00:00 23.6 2.1 28.7 17.9 23.4 2 27.9 18.3 21.9 1.9 26.8 16.1 305 11 305 165 -4.9 0 -4.6 -5 12/25/2006 11:10:00 25.7 1.7 30.2 21 25.4 1.7 30.2 20.6 23.1 2.1 28.7 17.6 302 10 304 165 -4.8 0.1 -4.4 -5 12/25/2006 11:20:00 25.4 2.1 29.8 18.7 25.1 2.1 30.6 18.7 23 2.3 28.3 16.8 303 8 300 165 -4.7 0 -4.4 -4.8 12/25/2006 11:30:00 26.3 1.8 30.2 21 26 1.8 29.8 21.4 23.4 2.1 28.7 17.9 303 8 302 165 -4.8 0 -4.6 -5 12/25/2006 11:40:00 23.7 1.9 28.3 18.3 23.5 1.8 27.9 18.7 22.5 1.9 27.5 17.2 309 9 302 165 -4.9 0 -4.6 -5 12/25/2006 11:50:00 23.5 1.4 26.8 19.9 23.3 1.3 26.3 19.9 23.2 1.6 27.9 19.1 313 9 314 165 -5 0 -4.8 -5.3 12/25/2006 12:00:00 25.8 1.9 30.6 21 25.5 1.9 30.2 20.6 25.9 2.1 32.1 19.9 317 7 315 165 -4.8 0.1 -4.4 -5 12/25/2006 12:10:00 27 1.7 31.8 21 26.7 1.7 31.8 20.6 27.2 1.8 31.8 21 318 6 316 165 -4.4 0.1 -4.2 -4.6 12/25/2006 12:20:00 28 1.9 32.1 23.3 27.7 1.9 31.8 22.9 27.9 2.4 33.2 21 317 7 317 165 -4.2 0 -3.9 -4.4 12/25/2006 12:30:00 27.5 2.3 32.4 21 27.3 2.2 32.1 20.6 27.3 2.4 32.4 19.5 315 7 319 165 -4.3 0 -4.2 -4.6 12/25/2006 12:40:00 27.2 1.9 32.4 21 26.9 1.9 32.4 20.6 27 2.1 32.1 20.6 316 7 309 165 -4.2 0 -3.9 -4.4 12/25/2006 12:50:00 26.4 1.7 30.6 21.4 26.1 1.6 30.2 20.2 26.4 1.7 30.6 19.5 316 6 315 165 -4.2 0 -3.9 -4.4 12/25/2006 13:00:00 23.3 1.9 27.5 17.9 23.1 1.9 27.5 17.6 23.1 2.1 29.1 17.9 316 8 314 165 -3.9 0 -3.5 -4.2 12/25/2006 13:10:00 21.8 1.9 27.9 16.8 21.6 1.9 27.5 16.4 21.1 2.1 27.9 14.9 314 10 315 165 -3.6 0.1 -3.3 -3.9 12/25/2006 13:20:00 19.8 2.1 26 15.3 19.7 2.1 26 15.3 19.4 2 25.2 14.5 318 11 315 165 -3.4 0 -3.3 -3.7 12/25/2006 13:30:00 21.2 2.2 26.8 16.1 21 2.2 26.3 15.6 20.5 2.5 27.5 14.5 316 9 317 165 -3.1 0 -2.8 -3.3 12/25/2006 13:40:00 21.1 2.2 26 14.9 20.8 2.2 26 14.9 20.8 2.4 26.3 14.1 318 8 322 165 -3 0 -2.8 -3.3 12/25/2006 13:50:00 23.9 2.2 29.4 17.6 23.6 2.2 29.4 17.9 23.5 2.5 28.7 16.8 318 8 312 165 -3 0 -2.8 -3.3 12/25/2006 14:00:00 22.8 1.8 26.8 17.6 22.5 1.7 26.3 17.6 22.3 2 27.1 16.4 320 7 321 165 -3.2 0 -2.8 -3.3 12/25/2006 14:10:00 24.2 2 29.1 16.4 24 1.9 29.1 16.8 23.8 2.3 28.3 15.6 315 8 310 165 -3.3 0 -3 -3.5 12/25/2006 14:20:00 23.2 1.6 27.1 17.2 22.8 1.6 26.3 17.6 23.2 1.7 27.5 17.9 322 7 322 165 -3.4 0 -3 -3.5 12/25/2006 14:30:00 23.5 1.9 28.3 18.7 23.3 1.9 27.9 18.7 23.1 1.9 28.3 17.6 315 7 302 165 -3.4 0 -3.3 -3.5 12/25/2006 14:40:00 20.8 2.4 27.9 16.4 20.5 2.3 27.1 16.1 20.4 2.7 27.9 13.7 320 9 331 165 -3.2 0 -3 -3.5 12/25/2006 14:50:00 18.6 2.6 24.8 13 18.4 2.6 24.8 13 18.1 2.6 24.8 12.6 319 13 312 165 -3.1 0.1 -2.8 -3.5 12/25/2006 15:00:00 17.1 2.6 24.8 9.9 16.9 2.6 25.2 9.9 16.7 2.7 24.4 9.5 322 15 316 165 -2.9 0 -2.8 -3 12/25/2006 15:10:00 13.6 1.7 17.2 9.1 13.4 1.6 17.2 8.8 12.8 1.6 17.2 8.8 314 11 302 165 -3 0.1 -2.8 -3.3 12/25/2006 15:20:00 13.6 2.6 20.2 7.2 13.4 2.5 19.9 6.8 12.4 2.3 18.7 7.2 312 12 306 165 -3 0 -2.6 -3 12/25/2006 15:30:00 15.3 2.8 21.8 8.4 15.1 2.8 21.4 8 14.3 2.9 20.6 8.4 314 10 316 165 -3 0.1 -2.8 -3.3 12/25/2006 15:40:00 15.5 2 19.9 10.3 15.3 1.9 19.9 10.3 14.6 2 19.9 9.1 314 9 308 165 -3.2 0 -3 -3.3 12/25/2006 15:50:00 15.4 1.7 19.1 9.9 15.2 1.7 19.1 9.9 14.8 1.7 19.1 9.9 315 11 334 165 -3.2 0 -3 -3.5 12/25/2006 16:00:00 13.4 1.9 18.3 8.4 13.2 1.8 17.9 8 12.8 1.7 17.2 8.4 318 11 311 165 -3.4 0 -3 -3.5 12/25/2006 16:10:00 11.7 1.5 16.1 7.6 11.5 1.5 15.6 7.2 11.2 1.6 15.6 7.2 315 6 320 165 -3.7 0 -3.3 -3.9 12/25/2006 16:20:00 11.6 1 14.9 9.1 11.4 1 14.9 9.1 11 1.1 13.7 7.6 317 8 317 165 -4.1 0.1 -3.7 -4.4 12/25/2006 16:30:00 10.1 0.8 12.6 7.6 9.9 0.8 12.2 8 9.8 0.9 12.2 7.6 319 7 328 165 -4.2 0 -3.9 -4.4 12/25/2006 16:40:00 8.9 0.7 10.7 7.2 8.8 0.7 10.7 6.8 7.8 1 9.9 5.3 307 8 301 165 -4.3 0 -3.9 -4.6 12/25/2006 16:50:00 8.1 0.9 10.3 5.7 8 0.9 10.7 5.7 6.2 0.9 9.1 4.2 296 7 289 165 -4.5 0.1 -4.2 -4.6 12/25/2006 17:00:00 9.1 1.3 12.6 6.8 9 1.3 12.6 6.5 7.1 1.3 11.8 4.2 295 8 300 165 -4.1 0.1 -3.5 -4.4 12/25/2006 17:10:00 9.2 1.4 12.6 6.1 9.1 1.4 12.6 6.1 7.4 1.2 11.5 4.6 297 9 280 165 -3.8 0 -3.5 -3.9 12/25/2006 17:20:00 9.7 1.9 13.3 6.1 9.6 1.9 13.3 5.7 7.7 1.6 12.6 4.6 294 9 297 165 -3.9 0.2 -3.5 -4.4 12/25/2006 17:30:00 9.7 1.3 13.7 6.1 9.6 1.3 13.7 6.5 7.8 1.2 11.5 4.9 290 6 296 165 -3.7 0 -3.5 -3.9 12/25/2006 17:40:00 10.3 1.1 13.3 7.6 10.2 1.1 13.3 7.6 8.3 1.4 12.6 5.3 291 7 288 165 -3.8 0 -3.5 -3.9 12/25/2006 17:50:00 11.5 1.5 14.1 7.6 11.4 1.5 14.1 7.2 9.6 1.7 14.1 5.7 292 8 292 165 -3.7 0 -3.5 -3.9 12/25/2006 18:00:00 11.9 1 14.5 7.6 11.8 1 14.5 8 9.9 1.7 14.9 5.3 289 6 282 165 -3.6 0 -3.5 -3.7 12/25/2006 18:10:00 12.3 1.3 14.9 8.4 12.2 1.3 14.9 8 10.2 1.7 14.9 6.8 290 7 293 165 -3.6 0 -3.3 -3.7 12/25/2006 18:20:00 11.1 1.3 14.9 7.6 11.1 1.3 14.9 7.6 8.7 1.5 13 5.7 295 9 304 165 -3.7 0 -3.5 -3.9 12/25/2006 18:30:00 9.2 1 11.5 6.5 9.1 1 11.5 6.1 7.5 1.1 10.7 4.9 295 9 305 165 -3.9 0 -3.7 -4.2 12/25/2006 18:40:00 11 1.4 13.7 6.5 10.9 1.4 13.7 6.5 8.8 1.3 12.6 4.9 292 8 281 165 -3.8 0 -3.5 -4.2 12/25/2006 18:50:00 10.8 1.7 14.9 7.6 10.7 1.7 14.9 7.2 8.5 1.5 14.5 5.7 294 8 291 165 -3.8 0 -3.5 -3.9 12/25/2006 19:00:00 12.1 1.4 15.6 7.2 12 1.4 15.6 7.6 9.7 1.5 14.5 5.7 294 8 303 165 -3.7 0 -3.5 -3.9 12/25/2006 19:10:00 10.1 1.7 14.9 6.1 10 1.7 15.3 6.1 8.1 1.5 13.3 4.9 295 9 281 165 -3.7 0 -3.5 -3.9 12/25/2006 19:20:00 8.1 1 10.7 5.3 8 1 11.1 5.3 7 1.3 10.7 4.2 291 10 293 165 -3.9 0 -3.5 -4.2 12/25/2006 19:30:00 7.5 1 9.9 4.9 7.5 1 9.9 4.6 6.4 1.2 9.5 3.4 289 10 292 165 -4.2 0.1 -3.9 -4.4 12/25/2006 19:40:00 8.2 1.2 10.7 5.3 8.2 1.2 10.7 5.3 6.8 1.3 9.9 3.8 293 9 287 165 -4.2 0 -3.9 -4.4 12/25/2006 19:50:00 8 1.4 11.5 5.3 8 1.4 11.5 5.3 7.2 1.6 10.7 4.2 286 7 280 165 -4.2 0.1 -3.9 -4.4 12/25/2006 20:00:00 7.6 1 11.5 5.3 7.6 1 11.1 5.3 6.7 1 9.5 4.2 288 8 277 165 -4.2 0 -3.9 -4.4 12/25/2006 20:10:00 8 0.9 9.9 5.7 8 0.9 10.3 5.7 7.5 1.1 9.9 4.2 284 8 287 165 -4.1 0 -3.9 -4.4 12/25/2006 20:20:00 6.1 1.3 8.8 3 6.8 0.8 9.1 5.3 6.5 0.9 8.4 4.9 271 5 279 165 -4.3 0 -3.9 -4.6 12/25/2006 20:30:00 6.3 0.6 7.6 4.2 6.3 0.6 7.6 4.6 6 0.8 7.6 3.8 282 5 274 165 -4.3 0 -4.2 -4.6 12/25/2006 20:40:00 5.9 0.8 8 3.4 6 0.7 8 3.4 5.7 0.7 7.2 3.4 279 6 281 165 -4.4 0 -4.2 -4.6 12/25/2006 20:50:00 5.3 1 8 3 5.4 1 7.6 3.4 4.9 1.1 7.2 2.6 281 9 280 165 -4.3 0 -4.2 -4.6 12/25/2006 21:00:00 5.6 1 8 3 5.7 1 9.1 2.6 5.1 1.2 8.4 3 282 13 263 165 -4.3 0.1 -3.9 -4.6 12/25/2006 21:10:00 5.1 1.2 8.8 2.6 5.1 1.2 8.4 3 4.5 1.1 7.2 2.3 284 10 296 165 -4.3 0 -3.9 -4.6 12/25/2006 21:20:00 6 0.7 8 4.2 6 0.7 8 4.2 5.3 1 7.6 2.6 285 8 281 165 -4.3 0 -4.2 -4.6 12/25/2006 21:30:00 5.9 1.1 8.4 3 6 1 8.8 3.8 5.4 1.1 8.4 3 281 8 278 165 -4.4 0 -4.2 -4.6 12/25/2006 21:40:00 7.9 1.4 12.2 4.9 8 1.4 11.8 5.3 7.4 1.3 11.1 4.2 281 6 276 165 -4.3 0 -4.2 -4.6 12/25/2006 21:50:00 8.2 1 10.7 5.3 8.3 1 11.1 5.3 7.8 1.2 10.7 4.2 281 5 280 165 -4.4 0 -4.2 -4.6 12/25/2006 22:00:00 8.1 1.1 11.8 5.3 8.2 1.1 12.2 5.3 7.7 1.2 11.1 4.2 281 6 274 165 -4.5 0 -4.4 -4.6 12/25/2006 22:10:00 10.4 1.1 13 7.6 10.5 1 13.3 7.6 9.6 1.3 13.3 4.9 284 6 291 165 -4.4 0 -4.2 -4.6 12/25/2006 22:20:00 9.1 1.7 13.3 4.9 9.2 1.6 13.3 5.3 8.4 1.6 13 4.6 281 9 291 165 -4.4 0 -4.2 -4.6 12/25/2006 22:30:00 9.3 1.4 12.6 6.5 9.3 1.4 12.6 6.5 8.5 1.5 12.2 5.3 284 7 282 165 -4.5 0 -4.4 -4.6 12/25/2006 22:40:00 10.1 1.4 13.3 6.8 10.1 1.4 13.3 6.8 9 1.7 13.3 5.3 285 10 287 165 -4.3 0 -4.2 -4.6 12/25/2006 22:50:00 10 1.9 14.9 5.3 10 1.8 14.1 6.1 9.1 1.7 13.7 4.6 282 9 296 165 -4.4 0 -4.2 -4.6 12/25/2006 23:00:00 10.7 1.8 16.1 6.5 10.7 1.8 16.1 6.1 9.7 2.1 14.9 4.9 282 9 244 165 -4.4 0 -4.4 -4.6 12/25/2006 23:10:00 10 2.1 14.9 4.9 10.2 2.2 14.9 4.2 9 2.3 15.3 4.2 287 16 282 165 -4.4 0 -4.2 -4.6 12/25/2006 23:20:00 10.8 1.5 16.8 6.8 10.7 1.5 16.4 6.8 9.2 1.7 14.5 4.9 290 11 299 165 -4.5 0 -4.4 -4.6 12/25/2006 23:30:00 10.3 1.9 16.1 6.1 10.3 1.9 16.4 6.1 8.8 2 14.5 4.6 293 12 307 165 -4.7 0.1 -4.4 -5 12/25/2006 23:40:00 9.6 2 15.6 6.1 9.7 2.1 15.3 5.7 8.7 2.4 14.9 3.8 285 13 291 165 -4.9 0 -4.6 -5 12/25/2006 23:50:00 9.9 1.7 14.1 5.3 9.9 1.7 13.7 5.3 8.3 1.6 12.6 4.2 291 13 287 165 -4.9 0 -4.6 -5 12/26/2006 00:00:00 8.9 1.7 13.7 3.8 8.8 1.7 13.7 3.8 7.6 1.7 12.2 3.8 292 13 290 165 -5 0 -4.6 -5.3 12/26/2006 00:10:00 9.5 2.1 14.9 4.9 9.4 2 14.9 4.9 8.3 1.7 13 3.4 288 13 319 165 -5 0 -4.6 -5.3 12/26/2006 00:20:00 9.5 1.5 13.3 4.9 9.6 1.5 13.3 4.9 8.9 1.7 13 3.8 280 9 292 165 -5.2 0 -5 -5.5 12/26/2006 00:30:00 9.6 1.5 12.6 5.3 9.6 1.5 12.6 5.7 8.7 1.7 13.7 3.8 286 11 289 165 -5.2 0 -4.8 -5.3 12/26/2006 00:40:00 11.1 1.5 15.6 6.5 11 1.5 15.6 7.2 9.6 1.7 14.5 5.3 285 9 279 165 -5.2 0 -5 -5.5 12/26/2006 00:50:00 11.2 1.4 14.5 4.6 11.2 1.4 14.5 5.3 9.9 1.9 14.9 6.1 285 10 282 165 -5.2 0 -5 -5.5 12/26/2006 01:00:00 9.8 1.5 12.6 6.5 9.7 1.5 13 6.1 8.8 1.5 13.7 4.9 285 9 276 165 -5.4 0 -5 -5.7 12/26/2006 01:10:00 9.8 1.5 13.3 5.3 9.9 1.4 13.3 6.5 9 1.5 13 5.3 281 9 270 165 -5.4 0 -5.3 -5.7 12/26/2006 01:20:00 10.6 1.3 14.9 7.2 10.6 1.3 15.3 7.2 9.8 1.5 14.5 6.1 283 8 251 165 -5.5 0 -5.3 -5.7 12/26/2006 01:30:00 10.8 1.3 14.9 7.6 10.9 1.4 14.9 7.6 9.8 1.7 13.3 6.5 281 9 275 165 -5.5 0 -5.3 -5.7 12/26/2006 01:40:00 10.5 1.6 14.5 6.5 10.6 1.4 14.5 6.5 9.7 1.6 14.9 5.3 280 10 277 165 -5.8 0.1 -5.5 -5.9 12/26/2006 01:50:00 9.4 1.7 13.3 5.3 9.3 1.7 13.3 5.3 8.1 1.8 12.2 4.2 284 12 273 165 -6 0 -5.7 -6.1 12/26/2006 02:00:00 9 1.7 11.8 4.6 9 1.7 12.2 4.6 8 2 11.8 3.4 283 11 277 165 -6.1 0 -5.7 -6.4 12/26/2006 02:10:00 8.6 2.2 13.7 3 8.5 2.2 13.7 3.4 7 2 13.3 2.3 295 14 289 165 -6.4 0 -6.1 -6.8 12/26/2006 02:20:00 9.2 2 13.7 3.8 9.1 2 14.1 4.2 8.1 2.2 13 3.4 285 10 285 165 -6.6 0 -6.4 -6.8 12/26/2006 02:30:00 8.8 1.5 13 5.7 8.8 1.5 12.6 5.3 7.8 1.6 12.2 4.6 286 12 289 165 -6.6 0 -6.4 -6.8 12/26/2006 02:40:00 4.8 1.1 7.6 2.3 4.8 1.1 8 2.3 3.7 1.1 8.4 1.1 298 22 278 165 -7.1 0.2 -6.6 -7.4 12/26/2006 02:50:00 4.5 1.2 9.1 1.1 4.6 1.3 9.1 1.1 3.9 1.2 7.6 1.1 287 36 301 165 -7 0.1 -6.6 -7.4 12/26/2006 03:00:00 6.8 1.6 10.7 3.4 7.2 1.8 12.2 3.4 6.4 1.9 11.5 1.9 282 29 266 165 -6.7 0 -6.6 -6.8 12/26/2006 03:10:00 7.4 2 11.8 3.4 7.4 1.8 11.8 3.4 6.2 1.7 10.3 2.6 293 21 287 165 -6.9 0 -6.8 -7 12/26/2006 03:20:00 3.6 1.3 7.2 0.7 3.8 1.3 6.8 0.7 3.4 1.1 6.1 0.7 273 26 307 165 -7.1 0 -6.8 -7.2 12/26/2006 03:30:00 4.1 1 6.8 1.1 4.1 1 6.8 0.7 3.4 0.8 5.3 1.5 291 24 291 165 -7.2 0.1 -6.8 -7.4 12/26/2006 03:40:00 6.1 1.9 10.7 0.4 6 1.9 10.7 0.4 5.4 1.9 10.3 0.7 296 23 300 165 -7.3 0.2 -6.8 -7.6 12/26/2006 03:50:00 5.8 1.4 9.1 2.3 5.8 1.4 8.8 2.3 5 1.4 8.8 1.5 294 15 281 165 -7.1 0.1 -6.8 -7.4 12/26/2006 04:00:00 5.1 1.5 7.6 1.5 5.1 1.4 7.6 1.5 4.4 1.2 7.6 1.5 293 16 319 165 -7.3 0.1 -7 -7.6 12/26/2006 04:10:00 5.9 1.7 9.1 1.5 5.9 1.7 9.5 1.5 5.3 1.6 8.8 1.9 299 22 279 165 -7.2 0 -6.8 -7.4 12/26/2006 04:20:00 4.2 1.1 7.2 1.5 4.2 1.1 6.8 1.9 3.9 1 6.5 1.5 285 22 321 165 -7.3 0 -6.8 -7.6 12/26/2006 04:30:00 1.5 0.8 3.8 0.4 1.4 0.8 3.8 0.4 1.7 0.8 4.2 0.4 329 76 323 165 -7.3 0 -7 -7.4 12/26/2006 04:40:00 4 1.5 6.8 0.7 3.8 1.5 6.5 0.7 3.6 1.3 6.5 1.1 321 22 325 165 -7.4 0.1 -7 -7.6 12/26/2006 04:50:00 2 1 5.3 0.4 1.9 1 5.7 0.4 2.1 0.9 3.8 0.4 235 61 268 165 -7.3 0 -7.2 -7.6 12/26/2006 05:00:00 2.6 1.3 4.9 0.4 2.6 1.4 5.7 0.4 2.6 1.3 5.3 0.4 243 41 259 165 -7.1 0 -6.8 -7.2 12/26/2006 05:10:00 1 0.7 3 0.4 0.9 0.7 3 0.4 1 0.7 3 0.4 180 51 183 165 -7.3 0.1 -7 -7.4 12/26/2006 05:20:00 2.3 1.2 5.3 0.4 1.9 1.2 4.9 0.4 2.1 1.1 4.9 0.4 335 36 319 165 -7.5 0 -7.2 -7.6 12/26/2006 05:30:00 1.8 1.2 6.1 0.4 1.8 1.2 4.9 0.4 1.8 1.2 4.9 0.4 334 86 233 165 -7.4 0.2 -6.8 -7.6 12/26/2006 05:40:00 2.5 0.8 4.6 0.4 2.3 0.9 4.9 0.4 2.5 1.1 6.5 0.4 348 76 102 165 -7 0 -6.8 -7.2 12/26/2006 05:50:00 2.1 1.2 5.7 0.4 2 1.2 5.7 0.4 2.1 1.1 4.9 0.4 115 69 131 165 -7.1 0 -6.8 -7.2 12/26/2006 06:00:00 2.5 1.5 6.5 0.4 2.4 1.5 6.1 0.4 2.7 1.6 6.1 0.4 212 69 162 165 -6.9 0.1 -6.6 -7.2 12/26/2006 06:10:00 1.4 0.9 3 0.4 1.3 1 3 0.4 1.4 1 3 0.4 231 36 220 165 -7 0.1 -6.6 -7.2 12/26/2006 06:20:00 1.5 0.9 3.8 0.4 1.4 0.9 4.2 0.4 1.4 0.8 3.4 0.4 226 66 250 165 -6.9 0.1 -6.6 -7.2 12/26/2006 06:30:00 1.4 0.7 3 0.4 1.2 0.7 2.6 0.4 1.2 0.6 3.4 0.4 248 53 343 165 -7.3 0.1 -6.8 -7.4 12/26/2006 06:40:00 2.5 1 4.9 0.4 2.4 1 4.9 0.4 2.6 1 4.9 0.4 221 21 245 165 -7.2 0.1 -6.8 -7.6 12/26/2006 06:50:00 3 1.3 6.8 0.7 3 1.3 7.2 0.7 3 1.2 7.2 1.1 256 17 271 165 -7.1 0.1 -6.8 -7.4 12/26/2006 07:00:00 4.7 1.1 7.2 2.3 5.3 1 7.6 2.6 5.1 1 6.8 3 267 11 266 165 -7 0 -6.8 -7.2 12/26/2006 07:10:00 7.7 1.5 9.9 3.4 7.8 1.2 9.5 4.6 7 1.2 9.5 4.2 285 10 292 165 -7.2 0.2 -6.8 -7.4 12/26/2006 07:20:00 8.5 0.7 10.3 6.5 8.5 0.7 10.7 6.1 7.3 1.2 10.3 4.6 287 6 285 165 -6.9 0.1 -6.6 -7.2 12/26/2006 07:30:00 8.1 0.5 9.1 6.8 8.1 0.5 9.5 6.8 6.8 1 9.1 4.9 289 4 286 165 -7.1 0 -6.8 -7.4 12/26/2006 07:40:00 9.2 0.4 10.3 7.6 9.2 0.4 10.7 8 7.5 0.9 10.3 5.3 291 4 294 165 -7.2 0 -6.8 -7.4 12/26/2006 07:50:00 10.1 0.6 11.5 8 10.2 0.6 11.5 8.4 8.9 1.1 11.1 5.7 287 4 282 165 -6.9 0.1 -6.6 -7.4 12/26/2006 08:00:00 9.5 1.1 11.1 6.5 9.5 1.2 11.1 6.1 8.1 1.7 11.1 4.2 287 5 285 165 -7.2 0.2 -6.8 -7.6 12/26/2006 08:10:00 7.4 1.4 11.1 4.2 7.3 1.3 10.7 4.2 6.9 1.3 10.7 3.8 319 13 319 165 -8.2 0.4 -7.4 -8.7 12/26/2006 08:20:00 10.9 0.6 12.2 8.8 10.7 0.6 11.8 8.8 9.3 1.2 11.8 6.1 309 7 302 165 -7.7 0.3 -7.2 -8.5 12/26/2006 08:30:00 10.1 1.4 12.2 6.5 9.9 1.4 12.2 6.1 7.6 1 9.9 4.6 295 7 296 165 -7.1 0.2 -6.8 -7.9 12/26/2006 08:40:00 7.6 1.5 10.7 2.3 7.5 1.5 10.3 1.9 5.4 1.5 9.9 0.7 289 16 296 165 -7.3 0.1 -6.8 -7.4 12/26/2006 08:50:00 8.6 1.3 11.1 5.3 8.5 1.2 10.7 4.9 6.6 1.4 10.3 3 289 9 288 165 -7.3 0 -6.8 -7.4 12/26/2006 09:00:00 7.5 1.5 9.9 3.4 7.4 1.3 9.9 4.6 5.6 1.7 9.5 1.5 286 10 293 165 -7.2 0 -6.8 -7.4 12/26/2006 09:10:00 5.9 1.8 9.5 1.1 6 1.7 9.5 1.1 4.5 1.7 8.4 1.1 283 22 292 165 -7.3 0 -7 -7.4 12/26/2006 09:20:00 7.9 1 11.1 5.3 7.8 1 10.3 5.3 6.6 1 9.1 3.8 297 11 295 165 -6.9 0.1 -6.6 -7.2 12/26/2006 09:30:00 7.5 0.9 9.9 5.3 7.4 0.9 9.5 5.3 6.2 1 9.1 4.2 306 7 306 165 -6.8 0.1 -6.4 -7 12/26/2006 09:40:00 6.6 0.9 9.1 4.9 6.6 1 9.1 4.6 5.9 0.8 8.4 4.2 311 8 305 165 -6.2 0.1 -5.7 -6.6 12/26/2006 09:50:00 3.2 1 5.7 1.1 3.1 1 5.7 0.7 3.1 1 5.7 1.5 306 23 318 165 -5.7 0.1 -5.5 -6.1 12/26/2006 10:00:00 4.9 0.7 6.5 3 4.9 0.7 6.8 3 4.2 0.8 5.7 2.3 297 10 295 165 -6 0 -5.7 -6.1 12/26/2006 10:10:00 6.9 0.7 9.1 5.3 6.9 0.7 9.1 5.3 5.6 0.8 7.6 3.4 303 9 298 165 -5.8 0.1 -5.5 -6.1 12/26/2006 10:20:00 5.9 0.9 7.6 3.8 5.8 0.9 8 3.8 5.5 1 7.6 3.4 318 12 315 165 -5.8 0.1 -5.7 -6.1 12/26/2006 10:30:00 3.8 0.8 6.1 1.1 3.6 0.9 5.7 1.5 3.7 0.8 6.1 1.5 322 18 330 165 -5.2 0.4 -4.6 -5.9 12/26/2006 10:40:00 3.8 1.3 6.5 0.4 3.7 1.3 6.1 0.4 3.2 1.1 6.1 0.4 298 11 316 165 -4.9 0 -4.6 -5.3 12/26/2006 10:50:00 1.4 0.6 3.4 0.4 1.1 0.6 3 0.4 1.5 0.6 3 0.4 191 43 238 165 -5 0.2 -4.4 -5.5 12/26/2006 11:00:00 1.1 0.7 3 0.4 0.9 0.8 3.4 0.4 1.1 0.7 3.8 0.4 338 98 260 165 -4.4 0.2 -3.9 -5 12/26/2006 11:10:00 1.2 0.3 2.3 0.4 0.8 0.4 1.9 0.4 1.3 0.3 1.9 0.4 141 15 125 165 -4.3 0.1 -3.9 -4.6 12/26/2006 11:20:00 0.8 0.4 1.9 0.4 0.5 0.4 1.5 0.4 0.8 0.5 1.9 0.4 53 72 354 165 -3.5 0.2 -2.8 -3.9 12/26/2006 11:30:00 1.7 0.5 3 0.7 1.5 0.7 3 0.4 1.7 0.5 3 0.7 28 36 84 165 -3.4 0.2 -2.8 -3.7 12/26/2006 11:40:00 1.5 0.4 2.6 0.7 1.5 0.4 2.6 0.7 1.4 0.5 2.6 0.4 78 28 112 165 -4.1 0.1 -3.5 -4.4 12/26/2006 11:50:00 1.2 0.5 2.6 0.4 1.2 0.5 2.6 0.4 1.2 0.6 2.6 0.4 100 38 133 165 -3.3 0.2 -2.8 -3.7 12/26/2006 12:00:00 1.9 0.6 3 0.4 1.8 0.6 3 0.4 1.9 0.6 3 0.4 138 14 153 165 -4 0.2 -3 -4.4 12/26/2006 12:10:00 1.2 0.4 1.9 0.4 1.2 0.4 1.9 0.4 1.1 0.4 2.3 0.4 271 30 283 165 -3 0.2 -2.6 -3.7 12/26/2006 12:20:00 1.6 0.8 3 0.4 1.5 0.7 3.4 0.4 1.6 0.8 3.4 0.4 186 38 160 165 -3.2 0.3 -2.6 -3.7 12/26/2006 12:30:00 1.6 0.7 2.6 0.4 1.5 0.7 2.6 0.4 1.4 0.8 2.6 0.4 235 33 268 165 -2.9 0.2 -2.6 -3.5 12/26/2006 12:40:00 1.8 0.2 2.3 1.1 1.8 0.2 2.3 1.1 1.8 0.2 2.3 1.1 254 10 252 165 -3.1 0 -3 -3.3 12/26/2006 12:50:00 1.1 0.5 1.9 0.4 1.1 0.5 2.3 0.4 1.2 0.5 2.3 0.4 304 98 276 165 -2.9 0.2 -2.6 -3.3 12/26/2006 13:00:00 2.3 0.6 3.4 0.7 2.1 0.6 3.4 0.7 2.3 0.5 3.8 1.1 167 8 169 165 -3.3 0.3 -2.6 -3.7 12/26/2006 13:10:00 2.6 0.3 3.4 1.9 2.5 0.4 3.4 1.9 2.5 0.4 3.4 1.9 169 9 153 165 -3.7 0.1 -3.3 -3.9 12/26/2006 13:20:00 1.5 0.4 2.3 0.7 1.4 0.4 2.3 0.7 1.4 0.5 2.3 0.7 181 15 180 165 -3.6 0.1 -3.3 -3.9 12/26/2006 13:30:00 0.9 0.5 1.9 0.4 0.9 0.5 1.9 0.4 0.9 0.5 1.9 0.4 269 10 286 165 -3.1 0.1 -2.8 -3.5 12/26/2006 13:40:00 2.8 1.3 4.2 0.4 2.6 1.2 4.2 0.4 2.8 1.2 4.6 0.4 189 33 165 165 -3.7 0.6 -2.6 -4.6 12/26/2006 13:50:00 3.2 0.3 3.8 2.6 3 0.3 3.8 2.3 3 0.3 3.8 2.3 167 6 171 165 -4.8 0 -4.4 -5 12/26/2006 14:00:00 3.1 0.3 3.8 2.3 2.9 0.3 3.8 2.3 2.9 0.3 3.8 2.3 156 6 153 165 -4.9 0 -4.6 -5 12/26/2006 14:10:00 2.6 0.5 3.8 1.5 2.5 0.4 3.4 1.5 2.6 0.4 3.4 1.5 144 5 147 165 -4.9 0 -4.6 -5.3 12/26/2006 14:20:00 1.1 0.4 1.9 0.4 1 0.4 1.9 0.4 1.1 0.4 1.9 0.4 132 1 138 165 -4.6 0.1 -4.4 -5 12/26/2006 14:30:00 1.1 0.4 1.9 0.4 0.9 0.5 1.9 0.4 1.2 0.4 1.9 0.4 136 7 132 165 -4.4 0 -4.2 -4.6 12/26/2006 14:40:00 2.2 0.7 3.4 0.7 2.1 0.7 3.4 0.7 2.2 0.7 3.4 1.1 157 5 154 165 -4.5 0.2 -4.2 -5 12/26/2006 14:50:00 4.2 0.6 5.7 3 4 0.5 5.7 2.6 4.1 0.5 5.3 3 152 5 152 165 -5 0.1 -4.6 -5.3 12/26/2006 15:00:00 4.8 0.4 5.7 3.8 4.6 0.4 5.3 3.4 4.6 0.4 5.3 3.4 150 14 153 165 -5.2 0 -4.8 -5.5 12/26/2006 15:10:00 4.7 0.5 5.7 3.4 4.5 0.5 5.3 3 4.5 0.5 5.7 3.4 154 11 160 165 -4.9 0 -4.6 -5.3 12/26/2006 15:20:00 4.7 0.6 5.7 3 4.4 0.6 5.3 3 4.3 0.6 5.3 3 155 15 157 165 -4.8 0.1 -4.6 -5 12/26/2006 15:30:00 4.7 0.3 5.3 4.2 4.4 0.3 5.3 3.8 4.4 0.3 4.9 3.4 153 9 157 165 -4.7 0 -4.4 -4.8 12/26/2006 15:40:00 4.6 0.4 5.3 3.4 4.4 0.4 4.9 3 4.5 0.4 5.3 3.4 153 5 152 165 -4.6 0 -4.4 -4.6 12/26/2006 15:50:00 4.1 0.5 5.3 2.3 3.8 0.5 5.3 2.3 4 0.5 5.3 2.6 153 8 153 165 -4.5 0 -4.4 -4.6 12/26/2006 16:00:00 4 0.3 4.9 3.4 3.7 0.3 4.6 3 4 0.3 4.6 3.4 155 10 148 165 -4.6 0 -4.4 -4.6 12/26/2006 16:10:00 3.7 0.3 4.2 3 3.5 0.3 4.2 2.6 3.6 0.3 4.2 3 156 9 147 165 -4.5 0 -4.4 -4.6 12/26/2006 16:20:00 2.8 0.4 3.4 1.5 2.6 0.4 3.4 1.1 2.7 0.4 3.4 1.5 154 9 156 165 -4.7 0 -4.4 -4.8 12/26/2006 16:30:00 3.6 0.7 4.9 2.3 3.4 0.7 4.6 1.9 3.2 0.6 4.6 1.9 144 11 118 165 -4.5 0.1 -4.2 -4.8 12/26/2006 16:40:00 2.9 0.9 4.6 1.1 2.8 0.9 4.6 1.1 2.7 0.7 4.2 1.1 130 6 134 165 -4.3 0 -4.2 -4.6 12/26/2006 16:50:00 2.5 0.8 4.2 1.5 2.4 0.8 4.2 1.1 2.5 0.8 4.2 1.5 144 8 145 165 -4.5 0 -4.4 -4.6 12/26/2006 17:00:00 4.4 0.5 6.1 3.4 4.3 0.5 5.7 3 4.4 0.5 5.7 3 151 8 147 165 -4.5 0 -4.4 -4.6 12/26/2006 17:10:00 3.7 0.7 5.7 2.3 3.5 0.7 5.7 2.3 3.4 0.7 5.3 1.9 145 8 144 165 -4.4 0 -4.2 -4.6 12/26/2006 17:20:00 4.2 1 6.5 2.3 4.1 0.9 6.5 2.3 4.1 1 6.5 2.3 145 6 144 165 -4.2 0.1 -3.9 -4.6 12/26/2006 17:30:00 3.3 0.5 4.9 1.9 3.2 0.5 4.6 1.9 3.1 0.5 4.2 1.9 142 8 124 165 -4.2 0 -3.9 -4.4 12/26/2006 17:40:00 3.6 0.6 4.9 2.3 3.5 0.6 5.3 2.3 3.4 0.5 4.9 2.3 138 9 133 165 -4 0 -3.9 -4.4 12/26/2006 17:50:00 3.5 0.8 5.7 1.9 3.5 0.8 5.7 1.9 3.2 0.7 5.3 1.9 129 12 132 165 -4 0.1 -3.5 -4.4 12/26/2006 18:00:00 2.5 0.8 4.6 0.7 2.4 0.8 5.3 0.7 2.4 0.7 4.2 0.7 130 15 95 165 -4.1 0.1 -3.9 -4.4 12/26/2006 18:10:00 2.9 0.6 4.6 1.5 2.8 0.6 4.6 1.5 2.8 0.5 4.6 1.5 128 13 153 165 -4 0 -3.7 -4.2 12/26/2006 18:20:00 3.8 0.6 5.3 2.6 3.7 0.6 5.3 2.6 3.5 0.6 5.3 2.3 126 11 136 165 -3.9 0 -3.5 -3.9 12/26/2006 18:30:00 4.9 1 6.8 1.9 5 1 6.8 2.3 4.5 0.9 6.5 2.3 112 7 112 165 -3.5 0 -3.3 -3.9 12/26/2006 18:40:00 6.4 0.6 7.6 4.6 6.4 0.6 7.6 4.6 6.2 0.6 7.2 4.6 116 6 120 165 -3.2 0 -2.8 -3.5 12/26/2006 18:50:00 6.8 0.4 7.6 5.7 6.9 0.4 8 5.7 6.5 0.5 7.6 4.6 117 3 115 165 -3.1 0 -2.8 -3.3 12/26/2006 19:00:00 7.4 0.7 9.1 6.1 7.5 0.7 9.1 5.7 7.1 0.7 9.1 5.3 116 5 119 165 -2.9 0.1 -2.6 -3.3 12/26/2006 19:10:00 7 0.8 9.1 4.6 7 0.9 9.5 4.9 6.9 0.8 9.1 4.2 116 8 122 165 -2.8 0 -2.6 -3 12/26/2006 19:20:00 7.4 1.3 9.9 4.6 7.5 1.3 10.3 4.2 7 1.3 9.5 3.4 111 5 110 165 -2.7 0.2 -2.4 -3 12/26/2006 19:30:00 9.3 0.7 11.5 6.8 9.4 0.8 11.8 7.2 8.8 0.9 10.7 6.1 113 5 115 165 -2.4 0 -2.1 -2.6 12/26/2006 19:40:00 9.6 0.8 11.8 7.2 9.8 0.8 12.2 7.2 9.1 0.9 11.5 6.1 114 4 111 165 -2.2 0 -1.9 -2.4 12/26/2006 19:50:00 9.5 0.6 11.1 8 9.6 0.6 11.5 8 9.1 0.7 10.7 7.2 114 4 114 165 -2.1 0 -1.9 -2.4 12/26/2006 20:00:00 9.8 0.8 11.8 7.2 9.9 0.8 11.8 7.2 9.6 0.8 11.8 7.6 118 6 111 165 -2 0 -1.7 -2.1 12/26/2006 20:10:00 9.8 0.5 11.5 8.4 9.9 0.5 11.5 8.8 9.4 0.8 11.1 6.8 117 6 125 165 -1.9 0 -1.7 -2.1 12/26/2006 20:20:00 9.3 0.7 11.1 6.8 9.4 0.8 11.5 6.8 8.9 0.9 10.7 5.7 118 6 111 165 -1.8 0 -1.7 -2.1 12/26/2006 20:30:00 9 1 11.5 5.3 9.1 1 11.5 5.3 8.6 1.1 11.1 5.3 117 6 121 165 -1.9 0 -1.7 -2.1 12/26/2006 20:40:00 8 0.6 9.9 6.1 8 0.6 9.5 6.5 7.7 0.6 9.1 6.1 121 6 117 165 -2 0 -1.9 -2.1 12/26/2006 20:50:00 8.3 1.1 11.1 6.1 8.3 1.1 11.1 6.5 8 1.1 11.1 6.1 121 5 119 165 -2.1 0 -1.7 -2.4 12/26/2006 21:00:00 8.3 1.1 10.7 6.1 8.3 1.1 10.7 6.1 8.2 1.2 10.7 5.3 125 5 124 165 -2.3 0 -1.9 -2.6 12/26/2006 21:10:00 7.9 0.8 10.3 5.7 7.9 0.8 10.3 5.3 7.5 0.9 9.5 5.3 122 6 122 165 -2.2 0.1 -1.9 -2.6 12/26/2006 21:20:00 8.6 1.3 11.5 5.7 8.7 1.2 11.8 6.1 8.2 1.3 11.5 5.7 123 8 112 165 -2 0 -1.7 -2.1 12/26/2006 21:30:00 10.5 1.7 14.5 6.5 10.6 1.7 14.5 6.1 10.2 1.7 14.5 6.5 121 9 121 165 -1.7 0 -1.4 -1.9 12/26/2006 21:40:00 11.1 1.2 13.7 7.6 11.1 1.2 13.7 7.6 10.6 1.2 13.7 6.5 123 7 114 165 -1.6 0 -1.4 -1.7 12/26/2006 21:50:00 12 1.2 15.6 9.1 12.1 1.2 15.6 9.1 11.8 1.2 15.3 8.8 126 6 132 165 -1.4 0 -1.2 -1.7 12/26/2006 22:00:00 12.8 1.2 15.6 9.1 12.9 1.3 16.1 9.9 12.4 1.3 16.1 9.1 129 7 135 165 -1.2 0 -0.8 -1.4 12/26/2006 22:10:00 13.9 1.2 16.8 9.9 14 1.3 16.8 9.5 13.6 1.3 16.4 9.5 124 6 128 165 -0.9 0 -0.8 -1.2 12/26/2006 22:20:00 12.9 1.3 16.4 9.1 13 1.3 16.4 9.1 12.7 1.4 15.6 9.1 124 5 122 165 -0.8 0 -0.5 -1 12/26/2006 22:30:00 12.4 1.4 16.4 9.5 12.5 1.4 16.4 9.5 12.3 1.3 15.6 9.1 123 6 114 165 -0.5 0 -0.3 -0.8 12/26/2006 22:40:00 11.5 1.3 15.6 8.4 11.6 1.3 15.6 9.1 11.4 1.2 15.6 8.4 123 7 116 165 -0.3 0 -0.1 -0.5 12/26/2006 22:50:00 13.1 1.5 17.2 8.8 13.2 1.5 17.2 8.8 12.8 1.5 17.2 9.1 121 6 136 165 -0.2 0 -0.1 -0.3 12/26/2006 23:00:00 14.1 1.5 19.5 10.3 14.4 1.5 19.9 10.7 13.9 1.5 18.7 10.7 123 7 126 165 0 0 0.2 -0.1 12/26/2006 23:10:00 17.1 1.7 21 13.3 17.4 1.7 21 13 16.9 1.9 21.4 12.6 125 7 119 165 0.2 0 0.7 0.2 12/26/2006 23:20:00 17 1.3 20.2 13.7 17.2 1.2 19.9 14.1 16.9 1.4 20.6 13 131 8 135 165 0.4 0 0.7 0.2 12/26/2006 23:30:00 16.8 1.4 20.6 13.7 17.1 1.4 21 13.7 16.8 1.5 21.4 12.6 128 7 129 165 0.4 0 0.7 0.2 12/26/2006 23:40:00 15.6 1.4 19.1 11.1 15.8 1.4 19.5 10.7 15.4 1.6 19.1 10.7 126 7 127 165 0.5 0 0.7 0.4 12/26/2006 23:50:00 16 1.4 19.5 12.6 16.2 1.4 19.9 12.6 16.1 1.4 19.9 12.6 128 6 135 165 0.7 0 0.9 0.4 12/27/2006 00:00:00 16.4 2 21 12.6 16.5 2 21 12.6 16.6 2 22.1 12.2 138 7 133 165 0.3 0.1 0.9 -0.1 12/27/2006 00:10:00 18.4 1.5 21.8 13.7 18.7 1.6 22.1 13.7 18.5 1.6 22.1 13.7 137 6 128 165 0.8 0.1 1.1 0.4 12/27/2006 00:20:00 20 1.5 23.3 14.5 20.3 1.5 23.7 15.3 19.8 1.7 24.4 13.7 136 6 142 165 1 0 1.4 0.9 12/27/2006 00:30:00 18.3 1.7 22.1 12.6 18.6 1.7 22.6 12.6 18.4 1.8 22.9 13 136 6 138 165 1.1 0 1.4 0.9 12/27/2006 00:40:00 19.3 1.6 22.9 15.3 19.4 1.7 22.9 15.3 19 1.8 23.3 13 137 6 136 165 1.2 0 1.4 0.9 12/27/2006 00:50:00 19.9 1.7 23.7 14.5 20.1 1.8 24 14.9 19.7 2.1 24.4 13 134 9 129 165 1.2 0 1.4 0.9 12/27/2006 01:00:00 18.7 1.3 22.6 14.9 18.8 1.3 22.9 14.9 18.5 1.5 22.1 14.1 132 8 137 165 1.2 0 1.4 0.9 12/27/2006 01:10:00 18.4 1.8 22.9 14.5 18.5 1.9 23.3 14.1 18.4 2 24 13 137 9 126 165 1.2 0 1.4 0.9 12/27/2006 01:20:00 21.2 1.7 25.2 14.9 21.3 1.8 25.2 14.5 21.1 2.1 26 14.1 136 8 133 165 1.2 0 1.4 0.9 12/27/2006 01:30:00 19.6 1.8 23.3 15.3 19.6 1.8 23.7 15.3 19.5 2 23.7 13.7 136 8 129 165 1.2 0 1.4 1.1 12/27/2006 01:40:00 19.6 1.9 23.7 14.9 19.7 2 24 15.3 19.3 2.2 24.4 13 132 9 129 165 1.2 0 1.4 0.9 12/27/2006 01:50:00 18.5 1.7 22.6 14.1 18.6 1.7 22.6 14.1 18.3 1.8 22.1 13.7 131 8 122 165 1.2 0 1.4 1.1 12/27/2006 02:00:00 18.1 2.2 24.8 11.8 18.3 2.2 24.8 11.8 17.9 2.3 24.4 12.6 127 8 122 165 1.2 0 1.4 0.9 12/27/2006 02:10:00 20.1 2 25.2 14.5 20.2 2 25.2 14.5 19.8 2.2 24.8 13.7 130 6 130 165 1.2 0 1.4 1.1 12/27/2006 02:20:00 19.4 1.7 23.7 13.7 19.6 1.7 24.4 14.1 19 1.8 22.9 13.3 127 6 123 165 1.1 0 1.4 0.9 12/27/2006 02:30:00 18.2 2.4 26 13.3 18.3 2.4 25.6 13.7 17.6 2.5 24 11.1 125 7 125 165 1.1 0 1.4 0.9 12/27/2006 02:40:00 20 2 24.8 14.9 20.2 2 24.8 14.9 19.7 2.3 24.8 12.2 124 6 129 165 1.1 0 1.4 0.9 12/27/2006 02:50:00 19.5 2 24.4 11.5 19.7 2 24.4 11.8 19.3 2.1 24 12.2 125 6 130 165 1.1 0 1.4 0.9 12/27/2006 03:00:00 19.6 2.2 24.8 12.6 19.8 2.2 24.8 13 19 2.4 25.2 13.3 124 8 120 165 1.1 0 1.4 0.9 12/27/2006 03:10:00 19.6 1.9 23.3 14.9 19.8 1.9 24 14.5 19.3 2 25.6 14.1 121 6 117 165 1 0 1.4 0.9 12/27/2006 03:20:00 19.2 2.2 24 14.1 19.4 2.2 24.4 14.1 18.8 2.2 24 13.7 121 6 118 165 1 0 1.4 0.9 12/27/2006 03:30:00 19.7 2.2 26.3 14.9 19.9 2.2 26.3 14.9 19.4 2.3 26.3 13.7 124 6 125 165 1 0 1.4 0.9 12/27/2006 03:40:00 20.9 2.1 24.8 13.7 21.1 2.1 25.2 14.5 20.5 2.3 24.8 13.7 121 5 124 165 0.9 0.1 1.1 0.9 12/27/2006 03:50:00 17.6 2 24 12.2 17.9 2 24.4 12.6 17.4 2.1 24.4 11.5 122 8 121 165 1 0 1.1 0.9 12/27/2006 04:00:00 18.6 1.7 22.6 13.7 18.8 1.7 23.3 13.7 17.9 1.8 23.7 12.6 118 8 113 165 0.8 0 0.9 0.4 12/27/2006 04:10:00 21 2.3 25.6 14.9 21.1 2.3 26.3 14.1 20.3 2.6 26 13 122 8 113 165 0.5 0.1 0.9 0.2 12/27/2006 04:20:00 20.3 2.7 25.6 12.2 20.4 2.7 26.3 12.6 19.6 2.9 26 12.6 122 9 125 165 0.1 0.2 0.7 -0.3 12/27/2006 04:30:00 20 2.6 26.8 11.1 20.1 2.6 27.1 11.5 19.5 2.8 26.8 12.2 121 7 121 165 -0.1 0 0.2 -0.3 12/27/2006 04:40:00 18.8 2.6 25.6 11.5 19 2.7 26 12.2 17.9 2.7 24 11.8 115 7 117 165 -0.2 0 0.2 -0.3 12/27/2006 04:50:00 19.8 2.5 25.6 13.7 20 2.4 25.6 14.5 19.1 2.5 24.8 13.3 117 7 117 165 0.1 0 0.4 -0.1 12/27/2006 05:00:00 20.5 3.1 27.1 12.2 20.6 3.1 27.1 12.2 19.7 3.2 26.8 12.2 120 8 124 165 -0.3 0.1 0.2 -0.5 12/27/2006 05:10:00 18.7 2.4 24.4 12.6 18.9 2.4 24.8 12.6 17.5 2.5 22.9 10.7 112 7 104 165 -0.3 0.1 -0.1 -0.5 12/27/2006 05:20:00 18.7 2.1 24 13.3 18.9 2.2 24.4 11.8 18.1 2.3 24 12.2 114 7 118 165 -0.5 0 -0.3 -0.8 12/27/2006 05:30:00 17.8 2.5 25.6 9.5 18.1 2.5 26 11.1 16.7 2.5 26.3 9.5 108 7 103 165 -0.4 0 -0.1 -0.5 12/27/2006 05:40:00 20 2.9 26.8 11.5 20.3 3.1 27.1 10.7 19 3.3 26.3 11.1 107 10 99 165 -0.3 0 -0.1 -0.5 12/27/2006 05:50:00 16.9 2.5 24.8 10.3 17.2 2.6 26 10.7 16.2 2.6 24 10.3 106 9 113 165 -0.2 0 0.2 -0.3 12/27/2006 06:00:00 20.5 2.7 26.8 12.2 20.9 2.8 27.9 12.2 19.4 2.9 26 11.8 106 7 109 165 -0.1 0 -0.1 -0.3 12/27/2006 06:10:00 23 2.1 27.1 14.5 23.3 2.1 27.9 15.6 21.6 2.6 27.5 13.3 105 7 112 165 -0.2 0 -0.1 -0.3 12/27/2006 06:20:00 20.9 2.5 26.3 12.2 21.1 2.5 26.8 12.2 19.3 2.6 26.3 13 106 7 107 165 -0.2 0 -0.1 -0.3 12/27/2006 06:30:00 20.8 3.1 26.3 12.6 21 3.2 26.3 13 19.1 3.1 25.2 11.5 99 8 100 165 -0.2 0 -0.1 -0.5 12/27/2006 06:40:00 20 2.5 25.6 12.6 20.2 2.6 26 12.6 18.7 2.6 25.6 11.5 99 7 101 165 -0.1 0 0.2 -0.3 12/27/2006 06:50:00 22 2.6 28.7 14.9 22.2 2.7 29.1 14.9 20.5 3.1 28.7 14.1 98 9 106 165 -0.1 0 0.2 -0.3 12/27/2006 07:00:00 21.2 2.5 27.1 14.5 21.5 2.5 27.5 14.1 20 2.7 26.8 13.3 98 8 92 165 0.1 0 0.2 -0.1 12/27/2006 07:10:00 22.1 2.1 26.8 16.4 22.4 2.2 27.5 16.4 20.8 2.6 26.3 13.7 95 7 99 165 0 0 0.2 -0.1 12/27/2006 07:20:00 22 2.6 28.7 15.6 22.4 2.7 29.1 15.6 21.1 2.8 28.7 14.9 90 8 82 165 0 0 0.2 -0.1 12/27/2006 07:30:00 21.9 2.5 28.3 16.1 22.3 2.5 28.7 16.1 21.2 2.7 27.1 14.5 92 7 88 165 -0.1 0 0.2 -0.3 12/27/2006 07:40:00 22.1 2.6 28.7 15.6 22.4 2.7 29.8 15.3 21.3 2.8 28.3 14.5 87 9 91 165 0 0 0.2 -0.1 12/27/2006 07:50:00 21.3 2.4 27.9 14.9 21.6 2.4 27.9 15.6 20.8 2.3 28.3 16.1 83 10 84 165 0.1 0 0.2 -0.1 12/27/2006 08:00:00 20.9 2.3 28.3 16.1 21.1 2.4 28.7 16.1 20.3 2.3 27.1 14.9 85 11 58 165 0.1 0 0.2 -0.1 12/27/2006 08:10:00 19.3 2.6 26.3 13 19.5 2.7 27.1 13.3 18.8 2.5 24.8 12.6 80 9 92 165 0.1 0 0.2 -0.1 12/27/2006 08:20:00 23.3 3.1 32.1 17.2 23.6 3.1 32.4 16.8 23 3.1 32.4 16.1 80 9 90 165 0 0 0.4 -0.1 12/27/2006 08:30:00 21.1 2.8 28.3 14.1 21.3 2.9 28.7 13.7 20.7 2.9 27.9 13 78 8 73 165 0.1 0 0.2 -0.1 12/27/2006 08:40:00 20.8 3.1 27.5 14.5 20.9 3.1 27.9 14.1 20.6 2.9 27.9 14.5 75 9 73 165 0.1 0 0.2 -0.1 12/27/2006 08:50:00 20.2 2.8 26.8 13.3 20.3 2.9 27.1 12.6 19.8 2.9 27.9 12.6 74 8 74 165 0.2 0 0.2 -0.1 12/27/2006 09:00:00 19.6 2.6 26.8 14.5 19.7 2.7 27.5 14.1 19.5 2.7 28.7 13 75 8 81 165 0.2 0 0.4 -0.1 12/27/2006 09:10:00 20.3 2.7 27.1 14.1 20.4 2.8 27.1 13.7 20.1 2.5 26.8 14.5 76 9 85 165 0.2 0 0.4 0.2 12/27/2006 09:20:00 20.4 2.7 27.1 14.1 20.5 2.8 27.5 14.5 20 2.7 26.8 13.7 74 9 83 165 0.3 0 0.7 0.2 12/27/2006 09:30:00 21.9 4 30.9 13.3 22.1 4.1 32.1 13 21.6 3.8 31.3 13 78 9 82 165 0.2 0 0.4 0.2 12/27/2006 09:40:00 21.6 2.9 29.8 13.3 21.8 3.1 30.2 13 21.2 2.9 30.9 14.9 76 9 84 165 0.2 0 0.4 0.2 12/27/2006 09:50:00 22.9 2.7 29.4 16.1 23.2 2.8 29.8 16.1 22.5 2.8 29.1 15.6 79 8 78 165 0.2 0 0.7 0.2 12/27/2006 10:00:00 20.7 3.1 29.4 13.3 20.8 3.2 29.4 13 20.2 3.1 28.7 12.6 76 9 84 165 0.3 0 0.7 0.2 12/27/2006 10:10:00 21.1 3.2 29.1 13.7 21.3 3.3 29.8 13.7 20.8 3.1 29.1 14.1 75 8 80 165 0.4 0 0.7 0.2 12/27/2006 10:20:00 21 2.8 28.7 13.3 21.1 2.8 29.1 13.3 20.6 2.9 30.6 13.3 75 8 81 165 0.5 0 0.7 0.2 12/27/2006 10:30:00 21.5 2.8 28.3 14.1 21.7 2.9 28.7 13.7 21 2.8 28.7 13 77 8 73 165 0.5 0 0.7 0.4 12/27/2006 10:40:00 21.4 2.9 28.7 14.5 21.7 3.1 29.4 14.9 21.1 3.1 29.8 14.5 80 7 77 165 0.6 0 0.9 0.4 12/27/2006 10:50:00 20.9 2.3 27.9 15.3 21 2.4 28.7 15.6 20.6 2.5 27.9 14.9 79 7 85 165 0.7 0 0.9 0.7 12/27/2006 11:00:00 20.9 2.7 27.1 13.3 21 2.8 27.1 13.3 20.8 2.7 27.1 14.5 79 7 76 165 0.7 0 0.9 0.7 12/27/2006 11:10:00 20.6 2.5 27.5 15.3 20.8 2.6 27.9 14.9 20.5 2.5 27.9 14.1 80 7 81 165 0.7 0 0.9 0.7 12/27/2006 11:20:00 20.6 2 25.2 14.9 20.9 2.1 25.6 15.3 20.6 2.2 26 14.9 81 7 71 165 0.8 0 0.9 0.7 12/27/2006 11:30:00 20.3 2.4 27.5 15.3 20.7 2.4 27.5 15.3 20.3 2.5 27.5 14.1 83 6 84 165 0.8 0 0.9 0.7 12/27/2006 11:40:00 19.6 2.5 25.2 13.7 20 2.6 25.2 13.7 19.7 2.6 26.3 13.7 84 7 84 165 0.8 0 0.9 0.9 12/27/2006 11:50:00 18.5 2.3 23.7 11.5 19 2.3 24 12.2 18.6 2.4 24 11.1 82 7 80 165 0.9 0 1.1 0.9 12/27/2006 12:00:00 18.8 2.1 24.8 13.3 19.2 2.2 25.2 13 18.9 2.3 25.6 13 87 9 85 165 1 0 1.4 0.9 12/27/2006 12:10:00 17.8 2 22.9 12.6 18.1 2.1 23.3 13.3 17.9 2.2 23.3 13 90 2 91 165 1.2 0 1.4 0.9 12/27/2006 12:20:00 17.7 2 21.8 13 18 2.1 22.6 13.3 17.5 2 22.6 12.6 90 0 91 165 1.3 0 1.4 1.1 12/27/2006 12:30:00 17.7 1.7 21.8 13.7 18 1.7 22.1 14.1 17.8 1.8 22.1 12.2 90 0 91 165 1.4 0 1.6 1.4 12/27/2006 12:40:00 17.5 1.9 21.8 12.2 17.9 2 22.1 12.6 17.7 2.2 22.9 11.5 90 0 91 165 1.4 0 1.6 1.4 12/27/2006 12:50:00 17.4 1.9 21 13 17.7 1.9 21.4 13 17.5 2 21.8 13.3 90 0 91 165 1.4 0 1.6 1.4 12/27/2006 13:00:00 16.6 1.6 20.2 11.8 16.9 1.7 20.2 11.8 16.9 1.7 21.8 12.2 90 0 90 165 1.4 0 1.6 1.4 12/27/2006 13:10:00 16.9 1.7 20.6 13 17 1.7 21 12.2 17 1.8 21.8 12.2 90 0 90 165 1.4 0 1.6 1.4 12/27/2006 13:20:00 17.7 1.4 21.8 14.1 17.9 1.4 21.8 14.1 16.9 1.8 21.4 10.3 91 1 91 165 1.8 0.1 2.1 1.6 12/27/2006 13:30:00 15.1 2.2 19.5 8.8 15.8 2.2 21 9.5 15.9 2.9 23.3 8.8 106 10 109 165 1.8 0 2.1 1.6 12/27/2006 13:40:00 14.6 2 18.3 9.5 15.4 2 19.5 10.3 16.4 2.5 21.4 10.3 105 8 104 165 1.7 0 1.8 1.6 12/27/2006 13:50:00 14.5 1.6 17.9 10.3 15.4 1.7 19.1 10.7 16.3 2 21 11.1 102 6 102 165 1.6 0 1.8 1.4 12/27/2006 14:00:00 13.2 1.7 17.6 8.8 14.3 1.7 18.7 9.1 15.3 2.1 19.9 9.5 103 6 105 165 1.4 0 1.6 1.4 12/27/2006 14:10:00 12.2 1.3 14.9 8.4 13.2 1.3 16.1 9.5 13.6 1.6 17.6 9.9 99 7 102 165 1.5 0 1.6 1.4 12/27/2006 14:20:00 13.6 1.5 17.2 9.5 14.8 1.8 19.1 10.3 14.9 1.7 19.1 9.1 97 7 99 165 1.8 0.1 2.3 1.6 12/27/2006 14:30:00 14.8 1.3 17.9 9.9 15.3 1.5 19.1 9.9 14.4 1.6 17.9 9.5 104 7 102 165 2.4 0.2 2.8 1.8 12/27/2006 14:40:00 14.4 1.6 17.9 9.9 14.5 1.6 18.3 9.5 13.9 1.7 17.6 8.8 112 7 119 165 2.8 0 3 2.6 12/27/2006 14:50:00 12.7 1.4 16.1 9.5 12.9 1.5 16.4 9.5 12.5 1.6 16.8 8 125 8 129 165 2.9 0 3.3 2.8 12/27/2006 15:00:00 13.7 1.4 17.2 10.3 13.7 1.3 17.2 9.9 13.5 1.4 17.2 9.1 136 8 132 165 3 0 3.3 2.8 12/27/2006 15:10:00 12.4 0.8 14.5 10.3 12.2 0.8 14.5 10.3 12.4 0.9 14.5 9.5 148 5 147 165 2.3 0.1 2.8 1.8 12/27/2006 15:20:00 13 1 16.8 10.7 12.7 1 16.4 9.9 13 1 16.4 10.3 151 17 167 165 2 0 2.3 1.8 12/27/2006 15:30:00 15.2 1 17.2 12.2 14.8 1 16.8 11.8 15.2 1.1 17.6 11.8 156 24 168 165 1.5 0.2 1.8 1.4 12/27/2006 15:40:00 16.2 0.9 17.9 13.3 16 0.9 17.9 13 16.4 1 18.7 13.7 161 23 30 165 1.3 0 1.6 1.1 12/27/2006 15:50:00 14.7 1 16.8 11.1 14.4 1 16.4 10.7 14.8 1 17.2 10.7 170 4 170 165 1.2 0 1.4 1.1 12/27/2006 16:00:00 14.7 2.3 22.6 10.3 14.5 2.2 21.8 10.3 14.8 2.3 24.4 10.3 183 7 202 165 1.3 0 1.4 1.1 12/27/2006 16:10:00 18.1 1.8 24 13.7 17.9 1.7 23.3 13.3 18.1 1.7 23.7 14.1 190 6 197 165 1.4 0 1.6 1.4 12/27/2006 16:20:00 19 2.5 27.5 12.2 18.8 2.5 27.1 11.8 19 2.5 26.8 13 192 5 193 165 1.4 0 1.6 1.4 12/27/2006 16:30:00 17.4 2.3 22.9 11.1 17.3 2.3 22.9 10.7 17.4 2.2 23.7 11.8 189 5 189 165 1.4 0 1.6 1.4 12/27/2006 16:40:00 13.9 1.8 19.5 9.9 13.7 1.8 19.5 9.9 14 1.9 20.2 9.5 186 2 187 165 1.2 0 1.4 0.9 12/27/2006 16:50:00 13.9 1.7 18.3 9.9 13.7 1.7 18.3 9.9 13.9 1.8 18.7 9.5 187 3 191 165 1.4 0 1.6 1.1 12/27/2006 17:00:00 15.4 2 20.2 10.3 15.2 2 19.9 10.7 15.6 1.9 20.2 10.7 188 7 197 165 1.6 0 1.8 1.4 12/27/2006 17:10:00 15.7 2.3 22.1 11.1 15.4 2.2 21.4 11.1 15.9 2.5 21.8 11.1 184 6 185 165 2 0.1 2.3 1.6 12/27/2006 17:20:00 15.1 1.8 20.2 11.1 14.8 1.8 19.9 10.7 15.2 1.9 20.2 10.7 182 10 191 165 2 0 2.3 1.8 12/27/2006 17:30:00 15 2.1 20.6 9.5 14.5 2.1 20.2 9.5 15.2 2.2 21 10.3 176 8 166 165 2.1 0 2.3 1.8 12/27/2006 17:40:00 15.8 1.6 19.9 11.8 15.4 1.5 19.5 11.5 15.9 1.5 20.2 11.8 179 11 182 165 2 0 2.3 1.8 12/27/2006 17:50:00 17.6 2.2 22.9 11.8 17.4 2.2 22.1 11.8 17.8 2.1 22.9 13 183 5 195 165 1.9 0 2.3 1.8 12/27/2006 18:00:00 16.1 2.6 23.3 10.7 15.8 2.5 23.3 10.7 16.2 2.6 23.7 11.1 183 5 192 165 1.9 0.1 2.3 1.6 12/27/2006 18:10:00 15.5 1.8 19.9 11.1 15.1 1.7 19.1 10.3 15.7 1.7 20.2 11.5 176 7 165 165 2 0 2.3 1.8 12/27/2006 18:20:00 15.3 2 21.4 10.7 14.9 2 21 10.3 15.4 1.9 21.8 11.8 178 6 179 165 2 0 2.3 1.8 12/27/2006 18:30:00 16.1 1.4 19.9 12.2 15.7 1.4 19.5 12.6 16.5 1.5 20.6 13 176 11 179 165 2.2 0 2.6 1.8 12/27/2006 18:40:00 16.7 1.5 20.6 12.6 16.3 1.5 19.9 12.2 16.8 1.5 21 13 178 8 184 165 2.1 0 2.3 1.8 12/27/2006 18:50:00 17 1.7 21 13 16.5 1.7 20.6 12.6 17.3 1.8 21.8 12.6 161 27 160 165 2 0 2.3 1.8 12/27/2006 19:00:00 17.7 1.6 21.8 12.6 17.2 1.5 21 13 17.8 1.5 22.1 14.1 168 23 167 165 2 0 2.3 1.8 12/27/2006 19:10:00 14 1.9 17.9 9.1 13.5 1.8 17.2 8.8 14.2 1.9 18.3 9.1 173 15 175 165 2 0 2.3 1.8 12/27/2006 19:20:00 13.6 2.1 18.7 9.9 13.2 2 18.7 9.5 13.6 2 19.5 9.5 169 19 124 165 1.8 0.1 2.3 1.6 12/27/2006 19:30:00 14.7 1.6 19.9 11.1 14.3 1.5 19.5 11.1 14.9 1.6 20.6 10.7 164 26 73 165 2.3 0 2.6 1.8 12/27/2006 19:40:00 12.8 2.1 20.2 7.2 12.4 2 19.5 7.2 12.9 2.1 20.6 9.1 180 10 176 165 2 0.2 2.3 1.6 12/27/2006 19:50:00 14.8 1.6 19.1 11.5 14.4 1.6 18.3 10.7 15 1.7 19.9 11.5 162 24 169 165 2.2 0 2.6 1.8 12/27/2006 20:00:00 17.1 1.5 22.6 13.3 16.7 1.4 21.8 13 17.3 1.4 20.6 13.3 156 28 127 165 2.1 0 2.6 2.1 12/27/2006 20:10:00 18.6 1.8 22.6 14.5 18.1 1.7 21.8 14.1 18.9 1.7 22.6 14.5 164 24 179 165 2.4 0.1 2.6 2.1 12/27/2006 20:20:00 18.4 1.4 21.8 14.1 17.9 1.3 21 13.7 18.4 1.5 21.8 14.1 171 23 174 165 2.4 0 2.8 2.3 12/27/2006 20:30:00 19 2.1 23.7 13 18.6 2.1 23.7 13.3 19.3 2.1 24.4 14.9 175 13 172 165 2.4 0 2.6 2.3 12/27/2006 20:40:00 18.4 1.5 22.6 14.9 17.9 1.4 21.8 14.5 18.7 1.5 22.9 14.5 164 26 176 165 2.4 0 2.6 2.3 12/27/2006 20:50:00 17 1.6 21.8 13.7 16.5 1.6 21 13.7 17.2 1.5 22.1 13 168 20 173 165 2.3 0 2.6 2.1 12/27/2006 21:00:00 18.1 1.1 21.4 15.6 17.5 1.1 20.6 14.9 18.4 1.2 21.8 14.1 166 21 172 165 2.5 0 2.8 2.3 12/27/2006 21:10:00 16 1 18.3 13.3 15.5 1 17.9 13 16.1 1.1 18.7 12.2 163 22 148 165 2.4 0 2.6 2.3 12/27/2006 21:20:00 14 1.2 16.8 10.7 13.6 1.2 16.4 10.7 14 1.3 16.4 11.1 155 22 167 165 2.3 0 2.6 1.8 12/27/2006 21:30:00 13.1 1.1 15.3 10.7 12.8 1.1 15.3 10.3 13.2 1.2 15.3 10.7 151 13 150 165 2.3 0.1 2.6 1.8 12/27/2006 21:40:00 16.1 2.1 21.4 11.8 16 2.1 21.4 11.8 15.9 2 20.6 11.1 148 22 2 165 2 0.4 2.6 1.1 12/27/2006 21:50:00 17.9 1.5 21.4 14.1 17.5 1.4 21 14.1 17.8 1.7 21.4 12.6 147 17 151 165 0.9 0.1 1.4 0.7 12/27/2006 22:00:00 14.2 2.4 19.1 9.5 13.8 2.3 18.7 8.4 14.1 2.4 19.1 9.1 153 13 156 165 0.8 0 1.1 0.7 12/27/2006 22:10:00 9.7 0.5 11.5 8.4 9.3 0.5 10.7 8 9.7 0.5 11.1 8.8 164 2 148 165 0.9 0 1.1 0.9 12/27/2006 22:20:00 9.6 0.6 10.7 8 9.2 0.6 10.7 7.6 9.5 0.6 10.7 8 164 0 164 165 0.9 0 1.1 0.9 12/27/2006 22:30:00 10.8 0.7 13 9.1 10.5 0.7 12.6 8.8 10.5 0.7 12.6 8.8 164 0 164 165 1.1 0 1.4 0.9 12/27/2006 22:40:00 10.5 0.6 11.8 8.8 10.2 0.6 11.5 8.4 10.3 0.7 12.2 8.4 164 0 164 165 1.2 0 1.4 0.9 12/27/2006 22:50:00 10.2 1.1 12.2 7.6 9.8 1 11.8 7.6 10.3 1 12.6 8 163 6 164 165 1.4 0 1.6 1.1 12/27/2006 23:00:00 10.2 0.9 11.8 7.6 9.8 0.8 11.8 7.2 10.2 0.9 12.2 8 158 9 164 165 1.4 0 1.6 1.4 12/27/2006 23:10:00 10.6 0.7 12.6 8.8 10.1 0.7 12.2 8.8 10.6 0.8 12.6 8.8 152 3 147 165 1.4 0 1.6 1.4 12/27/2006 23:20:00 10.7 0.6 11.8 9.1 10.4 0.6 11.5 8.8 10.6 0.6 11.8 8.4 148 3 148 165 1.5 0 1.6 1.4 12/27/2006 23:30:00 11.1 0.6 12.2 9.1 10.8 0.6 12.2 9.1 11 0.6 12.6 9.1 147 4 149 165 1.5 0 1.6 1.4 12/27/2006 23:40:00 11.1 0.9 13 8.8 10.7 0.9 12.6 8.4 11 0.9 13 8.4 147 3 148 165 1.6 0 1.6 1.6 12/27/2006 23:50:00 9.6 0.5 11.1 8 9.4 0.5 10.7 8 9.8 0.6 11.1 8 143 3 141 165 1.6 0 1.8 1.6 12/28/2006 00:00:00 10 0.6 11.1 8.4 9.7 0.6 11.1 8.4 10 0.7 11.5 8 145 3 147 165 1.7 0 1.8 1.6 12/28/2006 00:10:00 10 0.8 12.2 8 9.8 0.9 12.6 8 9.9 0.8 11.8 7.6 143 6 122 165 1.7 0 1.8 1.4 12/28/2006 00:20:00 12.4 1.5 15.6 9.5 12.2 1.5 15.6 9.5 12.4 1.5 16.1 9.5 148 6 150 165 1.5 0.1 1.8 1.4 12/28/2006 00:30:00 9.4 1.1 12.6 6.5 9.3 1.1 12.2 6.8 9.6 1.1 13.3 7.2 152 0 151 165 1.3 0 1.6 1.1 12/28/2006 00:40:00 8.3 0.7 10.3 6.5 8.2 0.7 10.3 6.5 8.2 0.8 10.3 6.5 152 0 151 165 1.3 0 1.6 1.4 12/28/2006 00:50:00 8.2 1 10.7 6.1 8 1 10.7 6.1 8.2 1 10.7 6.1 152 0 151 165 1.4 0 1.6 1.4 12/28/2006 01:00:00 6.6 0.5 8.4 5.3 6.6 0.5 8.4 5.3 6.6 0.5 9.1 5.3 152 0 152 165 1.4 0 1.6 1.4 12/28/2006 01:10:00 6.8 0.6 8.4 5.3 6.7 0.6 8.4 5.3 6.8 0.6 9.1 5.3 152 0 151 165 1.4 0 1.6 1.4 12/28/2006 01:20:00 6.6 0.9 8.8 4.9 6.5 0.9 8.8 4.6 6.6 0.9 8.8 4.9 152 0 152 165 1.4 0 1.6 1.4 12/28/2006 01:30:00 7.6 1 9.9 5.3 7.5 1 9.9 4.9 7.6 0.9 9.5 5.7 152 0 152 165 1.1 0.2 1.4 0.7 12/28/2006 01:40:00 5.7 0.5 6.8 4.6 5.6 0.5 6.8 4.2 5.6 0.5 6.8 4.2 152 0 151 165 0.7 0 0.9 0.7 12/28/2006 01:50:00 6.8 0.5 8.4 5.7 6.6 0.5 8 5.7 6.8 0.5 8.4 5.7 152 0 152 165 0.9 0 1.4 0.9 12/28/2006 02:00:00 7.2 0.5 8.4 6.1 6.9 0.4 7.6 5.7 7.1 0.5 8 6.1 152 0 152 165 1 0 1.4 0.9 12/28/2006 02:10:00 6.7 0.7 8.4 4.9 6.5 0.6 8 4.9 6.6 0.6 8.8 4.9 152 0 152 165 0.8 0.1 1.1 0.7 12/28/2006 02:20:00 6.6 0.8 8.8 4.6 6.4 0.8 8.4 4.6 6.5 0.7 8.4 4.9 152 0 152 165 0.8 0 0.9 0.7 12/28/2006 02:30:00 6.6 0.8 8.8 4.6 6.4 0.7 8.4 4.6 6.6 0.7 8.4 4.9 152 0 152 165 0.7 0 0.9 0.4 12/28/2006 02:40:00 5.4 0.6 6.8 4.2 5.2 0.6 6.8 3.8 5.3 0.6 6.8 4.2 152 0 151 165 0.5 0 0.7 0.2 12/28/2006 02:50:00 5.9 0.6 7.2 4.6 5.7 0.5 7.2 4.2 5.6 0.5 6.8 4.2 152 0 152 165 0.5 0 0.7 0.4 12/28/2006 03:00:00 6 0.5 7.2 4.9 5.7 0.4 6.8 4.6 5.7 0.5 7.2 4.9 152 0 152 165 0.7 0.1 0.9 0.4 12/28/2006 03:10:00 4.8 0.5 5.7 3.4 4.7 0.5 5.7 3 4.5 0.5 5.3 3.4 152 0 152 165 0.8 0 1.1 0.7 12/28/2006 03:20:00 4 0.4 5.3 3 4 0.4 5.3 3 3.4 0.4 4.6 2.3 152 0 152 165 0.8 0 0.9 0.7 12/28/2006 03:30:00 4.6 0.6 6.8 3 4.8 0.7 6.8 3 4.2 0.7 5.7 2.3 152 0 152 165 0.7 0 0.9 0.4 12/28/2006 03:40:00 4 0.7 5.7 1.9 3.9 0.7 5.7 1.9 3.4 0.8 4.9 1.1 152 0 152 165 0.5 0 0.9 0.4 12/28/2006 03:50:00 5.3 0.6 6.5 3 5.2 0.6 6.1 2.6 4.9 0.5 6.1 3 152 0 152 165 0.6 0 0.9 0.4 12/28/2006 04:00:00 6.8 0.6 8 4.9 6.8 0.5 8 4.9 6.2 0.6 7.6 4.6 152 0 152 165 0.6 0 0.9 0.4 12/28/2006 04:10:00 6.2 0.6 8 4.6 6.2 0.6 8 4.9 5.8 0.6 7.6 4.6 152 0 152 165 0.6 0 0.9 0.4 12/28/2006 04:20:00 6.4 0.6 8 4.9 6.3 0.6 7.6 4.9 6.2 0.5 7.6 4.6 152 0 152 165 0.7 0 0.9 0.4 12/28/2006 04:30:00 6.7 0.4 7.6 5.7 6.8 0.4 7.6 5.7 6.6 0.5 8 5.3 152 0 152 165 0.7 0 0.9 0.7 12/28/2006 04:40:00 7.6 0.6 10.3 5.7 7.7 0.6 9.9 6.1 7.4 0.6 8.8 5.7 152 0 152 165 0.7 0 0.9 0.7 12/28/2006 04:50:00 8.7 0.7 10.3 6.8 8.6 0.7 10.3 7.2 8.3 0.7 9.9 6.5 152 0 152 165 0.7 0 0.9 0.7 12/28/2006 05:00:00 7.8 1.1 10.7 5.3 7.6 1.1 10.3 5.3 7.7 1.1 10.7 5.7 152 0 152 165 0.7 0 0.9 0.7 12/28/2006 05:10:00 7.6 0.5 8.8 6.1 7.5 0.5 8.8 5.7 7.4 0.5 8.4 6.1 152 0 152 165 0.7 0 0.9 0.7 12/28/2006 05:20:00 6.5 0.6 7.6 4.9 6.2 0.6 7.6 4.9 6.4 0.6 8.4 5.3 152 0 152 165 0.7 0 0.9 0.7 12/28/2006 05:30:00 6.8 0.6 8 5.7 6.5 0.5 7.6 5.3 6.6 0.5 8 5.3 152 0 152 165 0.7 0 0.9 0.7 12/28/2006 05:40:00 5.3 0.6 6.8 3.4 5.1 0.6 6.5 3 5.2 0.6 6.8 3.4 152 0 152 165 0.8 0 0.9 0.7 12/28/2006 05:50:00 4 0.6 5.3 2.6 3.8 0.6 5.3 2.3 4.1 0.5 5.3 3 152 0 152 165 0.8 0 0.9 0.7 12/28/2006 06:00:00 4 0.5 5.7 3 3.8 0.5 5.3 2.6 4.2 0.5 5.7 3 152 0 152 165 0.8 0 1.1 0.7 12/28/2006 06:10:00 4.4 0.6 5.7 3 4.2 0.6 5.7 3 4.4 0.5 5.7 3 152 0 152 165 0.8 0 1.1 0.7 12/28/2006 06:20:00 2.6 0.6 3.8 1.1 2.4 0.6 3.8 0.7 2.8 0.5 4.2 1.5 152 0 151 165 0.8 0 1.1 0.9 12/28/2006 06:30:00 1.2 0.7 2.6 0.4 1 0.7 2.6 0.4 1.1 1 3.4 0.4 152 0 152 165 0.8 0 0.9 0.7 12/28/2006 06:40:00 2.3 0.8 4.6 0.4 2.2 1 4.6 0.4 2.5 0.8 4.2 0.7 152 0 152 165 0.7 0 0.9 0.7 12/28/2006 06:50:00 4.2 0.8 5.7 1.9 4.3 0.9 6.1 1.9 4.4 0.9 6.1 2.3 152 0 152 165 0.7 0 0.9 0.7 12/28/2006 07:00:00 4.3 0.5 5.7 3 4.5 0.6 6.1 3 4.5 0.7 6.1 2.6 152 0 152 165 0.7 0 0.9 0.7 12/28/2006 07:10:00 3.7 0.5 4.9 2.6 3.8 0.5 5.3 2.6 3.8 0.6 5.3 2.6 152 0 152 165 0.7 0 0.9 0.7 12/28/2006 07:20:00 4.7 0.6 6.1 3.4 4.5 0.6 5.7 3 4.7 0.5 6.1 3.8 152 0 152 165 0.7 0 0.9 0.7 12/28/2006 07:30:00 5.3 0.7 7.6 3.8 5.2 0.7 7.2 3.8 5.2 0.7 7.2 3.4 152 0 152 165 0.7 0 0.9 0.7 12/28/2006 07:40:00 3 1.5 6.1 0.4 2.8 1.6 5.7 0.4 3.2 1.3 5.7 0.7 152 0 152 165 0.8 0 0.9 0.7 12/28/2006 07:50:00 3.2 1.7 7.2 0.4 3.1 1.9 6.8 0.4 3 2.1 6.8 0.4 152 0 152 165 0.8 0 1.1 0.7 12/28/2006 08:00:00 3.4 1.1 6.1 1.9 3.3 1.2 6.5 1.5 3.8 1 6.8 2.3 152 0 152 165 0.8 0 1.1 0.9 12/28/2006 08:10:00 3.9 0.9 6.1 1.9 3.9 1 6.1 1.5 4.2 1 6.5 1.9 152 0 152 165 0.8 0 0.9 0.7 12/28/2006 08:20:00 3 0.6 4.6 1.1 3 0.7 4.6 0.7 3.4 0.6 4.6 1.5 152 0 152 165 0.8 0 0.9 0.7 12/28/2006 08:30:00 3 0.5 4.2 1.9 3 0.5 4.6 1.9 3.4 0.4 4.2 2.3 152 0 152 165 0.7 0 0.9 0.7 12/28/2006 08:40:00 3.6 0.5 4.9 2.3 3.8 0.6 5.3 2.6 3.8 0.6 5.3 2.6 152 0 152 165 0.7 0 0.9 0.4 12/28/2006 08:50:00 2.9 0.4 4.2 1.9 2.8 0.5 3.8 1.5 3.1 0.4 4.2 2.3 152 0 152 165 0.5 0 0.7 0.2 12/28/2006 09:00:00 3 0.6 4.2 1.5 3 0.6 4.2 1.1 3.4 0.5 4.6 1.9 152 0 152 165 0.4 0 0.7 0.2 12/28/2006 09:10:00 4.1 0.5 5.3 2.6 4.2 0.6 5.3 2.6 4.4 0.5 5.7 3 152 0 152 165 0.3 0.1 0.7 0.2 12/28/2006 09:20:00 3.5 0.7 5.7 2.3 3.6 0.7 5.7 1.9 3.7 0.7 5.3 1.9 152 0 152 165 0.1 0 0.2 -0.1 12/28/2006 09:30:00 2.8 0.6 4.6 1.5 2.8 0.7 4.6 1.1 3 0.5 4.6 1.9 152 0 151 165 0.1 0 0.4 -0.1 12/28/2006 09:40:00 3.6 0.9 6.1 1.5 3.6 0.9 6.1 1.1 3.7 0.7 5.7 2.3 152 0 152 165 0.1 0 0.2 -0.1 12/28/2006 09:50:00 1.9 0.9 4.6 0.4 1.7 0.9 4.6 0.4 2.1 0.6 4.6 0.7 152 0 152 165 0.1 0 0.2 -0.1 12/28/2006 10:00:00 3.8 1 5.7 0.4 3.6 1 5.7 0.4 4 0.9 6.1 1.5 152 0 152 165 0.1 0 0.7 -0.1 12/28/2006 10:10:00 2.6 1.7 6.8 0.4 2.4 1.7 6.8 0.4 3 1.4 6.8 0.7 152 0 152 165 0.3 0 0.7 0.2 12/28/2006 10:20:00 3.9 1.2 6.1 1.1 3.7 1.2 6.1 0.4 4.3 1 6.1 1.9 152 0 151 165 0.4 0 0.7 0.2 12/28/2006 10:30:00 6.1 0.7 8 4.6 6 0.7 8 4.6 6.2 0.6 8 4.9 152 0 151 165 0.6 0 0.9 0.4 12/28/2006 10:40:00 6.4 0.6 8 4.9 6.4 0.6 8 4.9 6.6 0.6 8 5.3 152 0 152 165 0.7 0 0.9 0.7 12/28/2006 10:50:00 5.3 0.5 6.8 3.8 5.2 0.5 6.8 3.8 5.4 0.5 6.5 3.8 152 0 152 165 0.7 0 0.9 0.7 12/28/2006 11:00:00 5 0.8 8 3.4 4.8 0.8 7.6 3.4 5 0.7 7.2 3.8 152 0 152 165 0.8 0 1.1 0.7 12/28/2006 11:10:00 5.1 0.6 6.5 3.4 5 0.6 6.5 3.4 5.2 0.5 6.5 3.8 152 0 152 165 1 0 1.1 0.9 12/28/2006 11:20:00 6 0.8 8.4 3.8 6 0.8 8.4 3.8 6.2 0.8 8 4.2 176 21 194 165 1.2 0.1 1.6 0.9 12/28/2006 11:30:00 6.7 1 8.8 4.2 6.6 0.9 8.8 4.2 6.7 0.9 8.8 4.2 191 5 193 165 1.4 0 1.6 1.4 12/28/2006 11:40:00 3.6 1.2 7.2 1.1 3.5 1.2 6.8 0.7 3.9 1 6.1 1.9 177 12 194 165 1.4 0 1.6 1.4 12/28/2006 11:50:00 2.3 0.9 4.2 0.4 2.1 0.9 3.8 0.4 2.4 0.8 4.2 0.4 186 18 105 165 1.5 0 1.8 1.4 12/28/2006 12:00:00 3.1 1.1 5.7 1.1 3.1 1.1 5.7 1.1 3.4 1.1 5.7 1.5 207 8 215 165 2 0 2.3 1.8 12/28/2006 12:10:00 4.1 1.1 6.1 1.5 4.1 1.1 6.5 1.5 4.5 1.1 6.5 1.5 199 10 199 165 2 0 2.3 1.8 12/28/2006 12:20:00 1.4 1 3.8 0.4 1.3 1 3.8 0.4 1.5 1 4.6 0.4 246 39 217 165 2.4 0.1 2.8 2.1 12/28/2006 12:30:00 2.9 1 5.3 0.4 2.8 1.1 4.9 0.4 3 1.2 5.3 0.4 210 19 194 165 2.6 0.1 2.8 2.3 12/28/2006 12:40:00 3.9 0.8 6.1 1.9 3.8 0.7 5.7 1.9 4.1 0.7 6.1 2.6 233 16 227 165 2.2 0 2.6 1.8 12/28/2006 12:50:00 4 0.7 5.7 1.9 4 0.7 5.3 1.5 4 0.8 6.1 2.3 207 9 207 165 2.3 0.1 2.8 2.1 12/28/2006 13:00:00 2.3 0.8 4.2 0.4 2.1 0.9 4.2 0.4 2.5 0.7 4.6 1.1 214 13 198 165 2.5 0 2.8 2.3 12/28/2006 13:10:00 1.3 0.8 3 0.4 1 0.6 2.6 0.4 1.3 0.7 3 0.4 293 39 356 165 2.9 0.2 3.3 2.6 12/28/2006 13:20:00 0.8 0.4 1.5 0.4 0.5 0.2 1.5 0.4 0.9 0.6 2.3 0.4 231 51 336 165 3.3 0 3.5 3 12/28/2006 13:30:00 0.6 0.5 2.3 0.4 0.5 0.4 2.3 0.4 0.7 0.6 2.3 0.4 266 90 166 165 3.6 0 4 3.3 12/28/2006 13:40:00 3.1 0.3 3.8 2.3 2.9 0.3 3.4 1.9 3.2 0.3 3.8 2.3 130 8 122 165 2.1 0.5 3.5 1.6 12/28/2006 13:50:00 3.4 0.4 4.2 2.3 3 0.4 3.8 1.5 3.5 0.4 4.2 2.3 152 8 128 165 1.7 0.1 1.8 1.6 12/28/2006 14:00:00 1.5 0.7 2.6 0.4 0.9 0.6 2.3 0.4 1.7 0.6 3 0.4 150 9 150 165 2 0 2.3 1.8 12/28/2006 14:10:00 0.5 0.3 1.5 0.4 0.4 0 0.4 0.4 0.6 0.3 1.1 0.4 131 90 351 165 2.4 0 2.6 2.3 12/28/2006 14:20:00 1.2 0.4 1.9 0.4 0.9 0.5 1.9 0.4 1.2 0.5 2.3 0.4 133 36 159 165 2.6 0.1 2.8 2.6 12/28/2006 14:30:00 0.4 0.1 1.1 0.4 0.4 0 0.4 0.4 0.4 0.2 1.1 0.4 168 0 168 165 3.7 0.7 4.8 2.6 12/28/2006 14:40:00 0.6 0.4 1.5 0.4 0.5 0.3 1.5 0.4 0.8 0.5 1.9 0.4 217 66 331 165 3.2 0.6 4.5 2.3 12/28/2006 14:50:00 1.6 0.3 2.3 0.7 1 0.5 1.9 0.4 1.5 0.2 1.9 0.7 4 21 27 165 2.7 0.3 3.3 2.1 12/28/2006 15:00:00 2 0.2 2.3 1.5 1.8 0.4 2.6 0.7 1.9 0.2 2.3 1.5 350 14 352 165 2.7 0.3 3.3 2.3 12/28/2006 15:10:00 2.1 0.4 3 1.1 1.6 0.4 2.6 0.7 2.1 0.5 3 1.1 21 10 15 165 2.7 0.1 3 2.3 12/28/2006 15:20:00 2.1 0.4 2.6 1.5 1.2 0.3 2.3 0.7 2 0.2 2.6 1.5 6 3 4 165 2 0.1 2.3 1.6 12/28/2006 15:30:00 2.4 0.3 3 1.5 1.5 0.4 2.3 0.7 2.4 0.3 3 1.5 8 5 6 165 1.2 0.3 1.8 0.7 12/28/2006 15:40:00 1.9 0.5 3 0.7 1.8 0.5 3 0.7 2 0.5 3 1.1 21 3 23 165 0.8 0.1 1.1 0.7 12/28/2006 15:50:00 2.3 0.8 3.4 1.1 2.3 0.9 3.4 0.7 2.3 0.6 3.8 1.1 27 17 43 165 0.6 0 0.7 0.7 12/28/2006 16:00:00 2.6 0.7 4.2 1.1 2.8 0.6 4.2 1.5 2.9 0.8 4.2 1.5 38 9 32 165 0.5 0.1 0.9 0.2 12/28/2006 16:10:00 3.6 0.3 4.2 3 3.7 0.3 4.2 3 3.8 0.3 4.6 3 34 3 34 165 0.1 0 0.4 -0.1 12/28/2006 16:20:00 3.9 0.3 4.6 3 4 0.3 4.6 3.4 4.1 0.3 4.9 3.4 29 4 29 165 -0.2 0.1 0.2 -0.5 12/28/2006 16:30:00 3.5 0.3 4.2 2.6 3.3 0.7 4.2 1.1 3.7 0.3 4.6 3 22 10 22 165 -0.2 0 -0.1 -0.5 12/28/2006 16:40:00 3.7 0.3 4.2 3 3.3 0.5 4.2 1.5 3.7 0.3 4.6 3 15 3 14 165 -0.6 0 -0.3 -0.8 12/28/2006 16:50:00 3.6 0.5 4.6 2.6 2 0.5 3.4 1.1 3.7 0.5 4.6 2.6 5 3 6 165 -0.6 0 -0.5 -0.8 12/28/2006 17:00:00 2.9 0.6 3.8 1.5 2.6 0.7 3.4 0.7 2.9 0.6 3.8 1.5 16 5 9 165 -0.5 0 -0.3 -0.8 12/28/2006 17:10:00 2.6 0.4 3.4 1.5 1.5 0.5 3 0.7 2.6 0.4 3 1.5 3 6 9 165 -0.5 0 -0.3 -0.5 12/28/2006 17:20:00 2.7 0.4 3.8 1.9 1.8 0.5 3 0.7 2.7 0.3 3.8 1.9 3 9 9 165 -0.4 0 -0.3 -0.5 12/28/2006 17:30:00 3.2 0.5 4.2 1.9 2.5 0.6 3.8 0.7 3.1 0.5 4.6 1.9 13 4 17 165 -0.3 0 -0.1 -0.5 12/28/2006 17:40:00 3.8 0.5 4.9 3 2.9 1 4.6 0.4 3.8 0.5 4.9 2.6 12 6 16 165 -0.3 0 -0.1 -0.5 12/28/2006 17:50:00 4.7 0.4 5.7 3.4 3.8 0.7 5.3 1.9 4.6 0.4 5.7 3.8 12 4 13 165 -0.2 0 -0.1 -0.3 12/28/2006 18:00:00 5.1 0.4 6.1 4.2 3.8 0.7 5.3 1.9 5.1 0.4 6.1 4.2 9 4 12 165 0 0 0.2 -0.3 12/28/2006 18:10:00 4.8 0.4 5.7 3.8 3.1 0.8 5.3 1.5 5 0.4 6.1 3.8 7 5 10 165 0.2 0 0.4 -0.1 12/28/2006 18:20:00 5.3 0.4 6.5 4.2 3.1 0.6 5.3 1.9 5.3 0.5 6.5 4.2 3 6 7 165 0.2 0 0.2 -0.1 12/28/2006 18:30:00 6.3 1 9.5 4.2 4.3 1.5 9.1 1.5 6.2 1 9.1 4.6 356 6 10 165 0.2 0 0.2 -0.1 12/28/2006 18:40:00 7.5 0.8 9.5 5.7 5.9 1.2 9.1 3 7.4 0.8 9.1 5.3 8 8 8 165 0.4 0 0.7 0.2 12/28/2006 18:50:00 7 1.2 10.3 4.6 5.4 1.3 9.1 2.6 7.1 1.3 10.7 4.6 354 9 5 165 0.5 0 0.9 0.2 12/28/2006 19:00:00 7 1.2 11.5 4.6 5.1 1.3 9.5 2.6 6.9 1.1 11.1 4.6 357 8 359 165 0.7 0 0.9 0.4 12/28/2006 19:10:00 8.7 1 11.1 5.7 7.3 1.3 10.3 3.8 8.5 1.1 11.1 5.7 350 7 350 165 0.8 0 0.9 0.7 12/28/2006 19:20:00 8.9 0.8 11.1 7.2 8.3 1.1 10.7 4.9 8.6 0.7 10.7 6.5 347 5 344 165 0.7 0 0.9 0.4 12/28/2006 19:30:00 9.4 1.3 13 6.1 8.7 1.7 12.6 4.2 9 1.3 12.2 5.7 346 8 347 165 0.7 0.1 0.9 0.4 12/28/2006 19:40:00 10.3 1 13 6.5 9 1.7 12.2 4.9 9.9 1 12.6 6.5 349 7 360 165 0.9 0 1.1 0.9 12/28/2006 19:50:00 12.2 1.3 15.3 7.6 10.1 1.9 15.3 6.1 11.9 1.4 15.6 6.8 351 7 344 165 0.9 0 1.1 0.9 12/28/2006 20:00:00 12.4 1.5 16.8 8 9.9 2.1 16.1 4.9 12 1.5 16.8 8.4 352 7 352 165 1 0 1.4 0.9 12/28/2006 20:10:00 13.2 1.4 17.6 8.4 10.7 2.1 14.9 6.1 12.9 1.4 16.8 8.8 352 6 356 165 1 0 1.4 0.9 12/28/2006 20:20:00 13.3 1.6 18.3 9.5 10.5 2.3 16.1 5.7 13 1.7 17.6 9.1 354 8 355 165 1.2 0 1.4 0.9 12/28/2006 20:30:00 13.5 2 17.9 8.4 10.9 2.4 16.4 4.9 13.1 2 17.2 7.2 353 8 344 165 1.2 0 1.4 0.9 12/28/2006 20:40:00 13.3 1.3 16.4 9.9 10.2 2.2 15.3 6.1 13.1 1.2 16.4 9.5 354 7 359 165 1.2 0 1.4 0.9 12/28/2006 20:50:00 14.1 2 18.7 9.1 10.5 2.3 16.4 6.1 14 2.1 17.9 8 355 6 360 165 1.3 0 1.6 1.1 12/28/2006 21:00:00 15 2.5 20.2 8.4 12.5 2.9 20.2 6.8 14.5 2.4 19.5 8.8 352 8 338 165 1.3 0 1.4 1.4 12/28/2006 21:10:00 13.9 1.6 17.6 9.9 11.1 2 16.8 6.5 13.4 1.5 17.2 9.1 353 7 1 165 1.2 0 1.6 0.9 12/28/2006 21:20:00 13.7 1.7 20.2 8.8 11.3 2.3 16.1 6.5 13.4 1.7 19.9 9.1 352 7 1 165 1.3 0 1.6 1.1 12/28/2006 21:30:00 16.1 1.9 22.6 10.3 13 2.6 18.7 7.2 15.6 1.9 22.1 10.3 353 6 360 165 1.2 0.1 1.4 0.9 12/28/2006 21:40:00 15.7 1.5 19.1 11.5 13.1 2.4 19.9 6.5 14.9 1.7 18.7 9.1 352 6 342 165 1.4 0 1.6 1.4 12/28/2006 21:50:00 14.8 1.7 20.2 11.1 12.2 2.1 18.7 7.2 14.3 1.6 18.7 9.9 353 9 360 165 1.4 0 1.6 1.4 12/28/2006 22:00:00 16.4 2.3 23.3 10.3 12.5 2.9 22.1 6.8 16 2.2 23.3 11.5 357 8 1 165 1.4 0 1.6 1.4 12/28/2006 22:10:00 15.1 2.1 22.9 11.1 12.3 2.3 19.9 7.6 14.6 2.1 22.1 9.9 356 9 358 165 1.1 0 1.6 0.9 12/28/2006 22:20:00 15.4 3.1 22.9 9.5 12.8 2.5 18.7 5.7 14.8 3.2 22.1 8.4 350 9 356 165 1.2 0.1 1.6 0.9 12/28/2006 22:30:00 17.4 2 23.3 9.5 13.3 2.5 19.5 8.4 16.9 2 22.9 9.9 356 8 346 165 1.5 0 1.6 1.4 12/28/2006 22:40:00 17.4 1.8 21 12.6 13.9 2.8 19.9 8.4 17 1.9 21 13 353 8 5 165 1.6 0 1.6 1.4 12/28/2006 22:50:00 17.5 2.7 23.3 10.3 14.5 2.5 21.4 9.1 17 2.9 22.9 9.9 349 13 360 165 1.4 0.1 1.6 1.4 12/28/2006 23:00:00 20.5 2.7 26.8 14.1 15.6 3.3 24.8 8.8 20.4 2.8 26.3 12.6 358 9 358 165 1.4 0 1.6 1.4 12/28/2006 23:10:00 19 3.3 27.5 11.1 16.1 3.8 26.8 8.8 18.8 3.3 27.9 11.1 356 12 17 165 1.4 0 1.6 1.4 12/28/2006 23:20:00 17.9 3.3 26 10.7 17.4 3.8 26.3 8 17.5 3.3 27.9 10.7 330 14 282 165 1.3 0 1.6 1.1 12/28/2006 23:30:00 23.4 2.4 29.1 17.2 22.9 2.6 28.7 15.3 23.4 2.6 29.8 15.6 332 10 330 165 1.2 0 1.4 0.9 12/28/2006 23:40:00 20.4 2.8 27.1 13 20.2 2.9 28.7 12.6 20 2.9 26.3 13.3 332 9 340 165 1.2 0 1.4 1.1 12/28/2006 23:50:00 18.7 3.2 27.5 11.5 18.5 3.5 27.5 6.5 18.4 3.3 27.5 10.3 328 11 311 165 1.2 0 1.4 0.9 12/29/2006 00:00:00 20.1 3.2 29.4 11.8 19.6 3.6 29.1 8.8 19.9 3.6 30.9 11.1 333 15 317 165 1.2 0 1.4 0.9 12/29/2006 00:10:00 19 3.1 27.1 10.7 18.5 3.2 28.3 10.7 18.9 3.1 26.3 9.9 336 12 339 165 1.1 0 1.4 0.9 12/29/2006 00:20:00 16.8 2.4 22.9 9.9 16.6 2.5 23.3 8.4 16.6 2.6 23.3 9.5 330 13 338 165 0.9 0 1.1 0.9 12/29/2006 00:30:00 17.2 2.5 24 10.7 16.9 2.6 22.6 10.7 17.1 2.6 23.7 10.7 330 13 356 165 1 0 1.4 0.9 12/29/2006 00:40:00 17.3 2.8 25.6 9.1 17.1 2.8 25.6 9.5 16.6 2.8 26 9.1 321 13 338 165 0.9 0 1.1 0.9 12/29/2006 00:50:00 19 3.2 27.9 10.7 18.6 3.3 27.1 10.3 18.2 3.2 26.3 9.5 322 17 300 165 1 0 1.4 0.9 12/29/2006 01:00:00 19.3 2.6 27.1 11.8 19.2 2.6 27.1 12.2 18.6 2.6 26.3 13 320 13 313 165 1.1 0 1.4 0.9 12/29/2006 01:10:00 18.7 3.8 28.7 10.3 18.5 3.8 28.3 9.9 18.4 4 29.4 10.3 329 12 334 165 0.9 0 1.1 0.9 12/29/2006 01:20:00 21.3 3.5 31.3 12.2 21.1 3.5 30.6 11.8 21.4 3.6 31.8 12.6 330 10 322 165 1 0 1.1 0.9 12/29/2006 01:30:00 24 5.1 34.8 12.6 23.6 5.4 35.2 12.2 23.7 5.4 36.3 12.2 331 12 325 165 0.9 0 1.4 0.9 12/29/2006 01:40:00 23.5 4 32.9 13.7 22.8 4.5 33.2 9.5 23.3 4.3 35.2 13.7 335 13 339 165 0.9 0 1.1 0.9 12/29/2006 01:50:00 24.4 4.3 36.3 12.2 23.7 4.5 35.5 11.5 24.4 4.7 37.5 11.1 334 13 332 165 0.8 0 1.1 0.9 12/29/2006 02:00:00 24 4 35.2 14.9 23.7 4.1 34.4 14.1 24.2 4 35.2 13.3 333 11 343 165 0.8 0 1.1 0.9 12/29/2006 02:10:00 23.2 4.1 34 13.7 22.8 4.3 34 10.7 22.6 4.5 34 13 333 12 325 165 0.9 0 1.1 0.9 12/29/2006 02:20:00 23.2 4.3 34 13 22.9 4.1 34 13.3 23.1 4.3 34.8 14.1 329 10 332 165 0.8 0 1.1 0.9 12/29/2006 02:30:00 22.7 4 36.7 13.7 22.5 4 35.5 12.2 22.2 4.3 39.4 10.3 330 11 343 165 0.9 0 1.1 0.9 12/29/2006 02:40:00 20.7 4.5 34.4 7.2 20.4 4.3 34 6.8 19.7 4.9 34.8 8.4 323 16 325 165 0.9 0 1.1 0.7 12/29/2006 02:50:00 22.8 3.5 34.4 11.8 22.6 3.8 35.9 11.5 22.2 4 37.8 7.2 325 14 317 165 0.8 0 1.1 0.7 12/29/2006 03:00:00 27.1 4.5 37.8 14.1 26.9 4.5 38.6 14.5 27 4.7 39.4 13 326 13 319 165 0.7 0 0.9 0.4 12/29/2006 03:10:00 26.8 5.1 40.9 14.9 26.3 5.4 40.5 14.9 26.8 5.4 42.4 15.3 330 13 330 165 0.7 0 0.9 0.7 12/29/2006 03:20:00 23.8 4.5 38.2 12.2 23.1 4.9 37.8 12.6 23.6 4.9 37.8 14.1 333 14 323 165 0.6 0 0.9 0.4 12/29/2006 03:30:00 25 4.9 40.5 14.1 24.6 5.1 40.1 12.2 24.8 5.1 38.6 14.5 331 13 325 165 0.3 0.1 0.7 0.2 12/29/2006 03:40:00 24.8 5.1 38.2 10.3 24.6 5.4 38.2 8.4 24.5 5.6 40.1 11.8 325 14 317 165 0.1 0 0.4 -0.1 12/29/2006 03:50:00 27.3 4.7 37.5 11.8 27.1 4.7 37.1 10.3 27.2 5.1 40.9 11.5 325 11 338 165 0.1 0 0.2 -0.1 12/29/2006 04:00:00 27.4 4.9 39.8 14.5 27.1 5.1 38.6 13.7 27.4 5.1 40.9 9.5 328 13 335 165 0.1 0 0.7 -0.1 12/29/2006 04:10:00 29.7 4.7 42.1 17.2 29.3 4.9 42.1 16.1 29.5 4.9 41.3 16.8 330 14 334 165 0 0 0.2 -0.1 12/29/2006 04:20:00 27.5 4.9 43.9 15.3 26.8 5.1 43.2 14.5 27.3 4.7 43.9 17.9 336 11 348 165 -0.1 0 0.2 -0.3 12/29/2006 04:30:00 27.7 3.8 37.5 17.2 27.2 3.8 36.3 17.2 27.4 4.1 38.2 17.6 335 9 331 165 -0.2 0 -0.1 -0.3 12/29/2006 04:40:00 24.8 4.1 36.3 14.1 24.4 4.3 36.7 13 24.4 4.3 37.1 13 335 12 344 165 -0.2 0 -0.1 -0.3 12/29/2006 04:50:00 25 4.1 36.7 14.1 24.5 4.1 35.5 13 24.6 4.1 36.7 13 333 11 356 165 -0.1 0 0.2 -0.3 12/29/2006 05:00:00 26.7 4.9 39 13.7 26.5 5.1 38.6 13.7 26.3 5.1 38.2 13 330 10 334 165 -0.1 0 0.2 -0.3 12/29/2006 05:10:00 27.9 4.3 39.4 16.4 27 4.5 39 16.1 27.6 4.5 39 14.5 337 14 341 165 -0.1 0 0.2 -0.3 12/29/2006 05:20:00 25.6 4.7 35.9 13.3 25.1 4.9 35.5 13.7 25.4 4.7 36.3 14.9 331 11 330 165 -0.1 0 0.2 -0.3 12/29/2006 05:30:00 30.6 4.3 40.9 15.3 29.6 4.7 40.1 14.1 30.4 4.7 42.1 15.3 335 12 332 165 -0.1 0 0.2 -0.3 12/29/2006 05:40:00 28.6 4 39.8 18.3 28.1 4 38.6 16.1 28.3 4.1 39.8 19.1 334 11 354 165 -0.1 0 0.2 -0.3 12/29/2006 05:50:00 23.8 3.6 33.6 16.1 22.7 3.5 32.4 14.9 23.3 4 31.8 15.3 331 17 354 165 -0.1 0 -0.1 -0.3 12/29/2006 06:00:00 20.9 2.4 27.5 13 20.8 2.4 27.1 13 19.7 2.5 27.1 13.7 313 12 320 165 -0.2 0 -0.1 -0.3 12/29/2006 06:10:00 21.9 2.7 30.6 12.2 21.8 2.6 30.2 13.7 20.7 2.9 28.7 13.7 312 14 297 165 -0.3 0 -0.1 -0.5 12/29/2006 06:20:00 23.3 2.7 34 15.6 23.3 2.7 34 16.8 22.3 2.9 30.2 14.5 307 13 285 165 -0.2 0 0.2 -0.3 12/29/2006 06:30:00 26.8 3.2 35.5 19.1 26.7 3.2 35.5 19.1 25.7 3.6 35.9 17.6 309 12 307 165 -0.1 0 0.2 -0.3 12/29/2006 06:40:00 26.4 3.3 37.8 17.6 26.4 3.3 36.7 18.7 25.6 3.5 33.2 17.6 308 10 285 165 -0.1 0 0.2 -0.3 12/29/2006 06:50:00 26.1 3.2 37.8 19.1 25.9 3.2 37.8 18.7 24.8 3.1 32.9 15.3 308 12 297 165 -0.1 0 -0.1 -0.3 12/29/2006 07:00:00 25.1 3.1 36.7 17.9 24.9 3.1 37.1 17.6 23.7 2.9 34 15.6 308 13 284 165 -0.1 0 -0.1 -0.3 12/29/2006 07:10:00 26.4 3.8 36.7 16.8 26.2 3.8 36.7 17.2 25.1 4 37.5 14.9 311 14 289 165 -0.2 0 -0.1 -0.3 12/29/2006 07:20:00 26.4 3.6 35.9 17.2 26.2 3.6 35.9 17.6 25.4 3.8 35.5 14.9 310 15 281 165 -0.1 0 0.2 -0.3 12/29/2006 07:30:00 28.5 4.1 43.2 19.5 28.4 4.1 43.6 19.1 27.5 4.1 37.1 19.1 311 12 286 165 -0.1 0 0.2 -0.3 12/29/2006 07:40:00 29.1 3.3 39.4 20.2 29 3.3 39.4 19.9 28.2 3.8 39.8 19.9 310 11 319 165 0.1 0 0.2 -0.1 12/29/2006 07:50:00 28.3 4 39 19.1 28.1 4 39.4 19.1 27.4 4.5 38.6 15.6 314 14 318 165 0.1 0 0.2 -0.1 12/29/2006 08:00:00 27.9 3.3 37.5 18.7 27.9 3.3 37.8 18.7 27.7 3.5 38.6 18.3 313 10 308 165 0 0 0.2 -0.1 12/29/2006 08:10:00 27.1 3.8 37.1 19.1 26.9 3.6 37.5 18.7 26.1 4.1 37.8 15.3 313 13 305 165 0.1 0.1 0.4 -0.1 12/29/2006 08:20:00 27.5 3.2 37.1 18.7 27.4 3.2 36.7 18.7 27.1 3.6 37.1 18.7 311 10 309 165 0.2 0 0.4 -0.1 12/29/2006 08:30:00 27.2 2.9 35.5 19.9 26.9 3.1 35.5 19.1 27.1 3.2 35.5 21 317 11 319 165 0.1 0 0.4 -0.1 12/29/2006 08:40:00 26.2 2.4 32.1 19.9 26 2.4 31.8 19.5 26.1 2.7 33.6 17.2 314 9 323 165 -0.2 0.2 0.2 -0.8 12/29/2006 08:50:00 27.2 2 33.2 21.8 27 1.9 33.2 21.4 27.2 2.2 34.4 21 314 6 325 165 -0.6 0 -0.3 -0.8 12/29/2006 09:00:00 28.7 2 33.6 24.4 28.5 2 33.6 24 28.6 2.2 34 23.7 313 6 309 165 -0.5 0.1 -0.1 -0.8 12/29/2006 09:10:00 28.7 2.4 34.8 22.9 28.5 2.3 35.2 21.8 28.8 2.3 34.8 23.7 316 7 319 165 -0.2 0 -0.1 -0.3 12/29/2006 09:20:00 27.2 1.8 33.6 22.9 27 1.8 33.6 22.9 27.3 2 33.2 22.1 315 6 309 165 -0.1 0 0.2 -0.1 12/29/2006 09:30:00 27.5 1.8 31.8 21.8 27.2 1.7 30.9 21.4 27.7 1.7 31.8 22.6 316 5 313 165 0.1 0 0.2 -0.1 12/29/2006 09:40:00 26.4 2 32.4 21.4 26 1.9 31.8 21.4 26.5 2.1 33.2 20.6 318 6 319 165 0.2 0 0.4 -0.1 12/29/2006 09:50:00 25.7 1.5 29.1 21.4 25.4 1.5 28.7 21 25.5 1.7 31.3 20.2 316 6 306 165 0.2 0.1 0.7 0.2 12/29/2006 10:00:00 26.8 1.6 30.9 22.1 26.5 1.6 30.2 22.9 27 1.8 32.1 21.4 318 5 316 165 0.4 0 0.7 0.2 12/29/2006 10:10:00 26 2.1 30.9 19.9 25.7 2 30.6 19.9 26 2.2 30.6 19.1 317 5 319 165 0.5 0 0.9 0.2 12/29/2006 10:20:00 25.2 1.7 28.3 20.2 24.8 1.7 27.9 20.2 25.3 1.9 29.8 19.9 317 6 325 165 0.4 0 0.7 0.2 12/29/2006 10:30:00 24.2 1.3 27.9 20.2 23.9 1.3 27.1 19.9 24 1.5 28.7 19.1 315 6 332 165 0.3 0.1 0.7 0.2 12/29/2006 10:40:00 23.8 2 28.3 18.7 23.6 1.9 28.3 18.7 23.6 2 27.9 18.3 316 6 312 165 0.3 0 0.7 0.2 12/29/2006 10:50:00 24.8 1.3 27.5 21 24.5 1.3 27.1 21.4 24.7 1.6 27.9 19.5 318 7 307 165 0.4 0 0.7 0.2 12/29/2006 11:00:00 24.8 1.6 28.7 20.6 24.5 1.6 28.3 20.6 24.8 1.7 28.7 19.1 318 6 310 165 0.5 0 0.7 0.2 12/29/2006 11:10:00 24.7 1.2 28.3 21.4 24.3 1.2 27.5 20.6 24.9 1.4 29.1 19.5 319 5 328 165 0.5 0 0.7 0.4 12/29/2006 11:20:00 23.4 1.9 28.3 17.2 23 1.9 27.5 16.8 23.4 2.2 28.3 19.1 321 5 316 165 0.7 0 0.9 0.4 12/29/2006 11:30:00 23.3 1.3 26.8 17.6 22.9 1.3 26.8 16.4 23.2 1.3 26.3 19.1 320 5 328 165 0.6 0 0.9 0.4 12/29/2006 11:40:00 24.2 2.3 31.3 18.3 23.8 2.3 29.8 18.3 24.2 2.4 30.2 19.5 322 7 325 165 0.7 0.1 0.9 0.4 12/29/2006 11:50:00 25.8 1.8 30.2 20.6 25.4 1.8 29.4 20.2 25.8 2 30.6 19.5 320 6 328 165 0.9 0 1.1 0.9 12/29/2006 12:00:00 24 2.1 29.1 16.8 23.7 2 28.3 16.8 24 2.3 29.1 17.2 319 7 325 165 1.1 0 1.4 0.9 12/29/2006 12:10:00 23 2.1 28.3 16.1 22.8 2.1 27.9 15.6 22.8 2.3 27.9 16.1 319 9 323 165 1.1 0 1.4 0.9 12/29/2006 12:20:00 22.5 1.8 27.5 17.2 22.2 1.7 27.5 17.2 22.3 1.8 26.8 16.4 319 8 328 165 0.8 0 1.1 0.7 12/29/2006 12:30:00 21.3 1.8 26.3 15.6 21.1 1.8 26.3 15.6 21.1 2.2 27.1 16.1 327 9 322 165 0.7 0 0.9 0.4 12/29/2006 12:40:00 20.9 2.2 27.1 15.3 20.8 2.3 26.8 14.9 20.5 2.4 26 14.9 318 9 328 165 0.7 0 0.9 0.4 12/29/2006 12:50:00 21.2 1.9 26.8 16.1 21 1.9 27.1 16.1 20.8 2 26.3 14.9 319 8 324 165 0.6 0 0.9 0.4 12/29/2006 13:00:00 23.6 1.5 27.1 17.6 23.2 1.5 27.1 17.2 23.4 1.7 27.5 17.9 317 5 315 165 0.5 0 0.9 0.4 12/29/2006 13:10:00 24.3 1.6 28.7 18.7 24 1.7 28.7 18.3 24.3 1.7 29.4 18.3 316 6 316 165 0.5 0 0.7 0.2 12/29/2006 13:20:00 26 2.4 32.4 19.1 25.8 2.4 32.1 18.7 25.9 2.5 32.4 19.9 319 7 313 165 0.7 0.1 1.1 0.2 12/29/2006 13:30:00 26.7 2 31.3 20.6 26.5 1.9 30.9 20.6 26.7 2.3 32.4 20.2 320 7 318 165 0.8 0 0.9 0.7 12/29/2006 13:40:00 26.4 2.1 30.6 18.7 26.2 2 30.6 19.1 26.4 2.1 31.8 19.9 320 7 319 165 0.8 0 0.9 0.7 12/29/2006 13:50:00 25.9 2 30.9 21 25.7 2 30.6 20.6 25.8 2.4 31.3 18.3 316 6 316 165 0.8 0 1.1 0.7 12/29/2006 14:00:00 23.4 1.8 28.3 19.5 23 1.8 27.9 19.1 23.1 2.3 27.9 17.9 316 7 319 165 0.7 0 0.9 0.7 12/29/2006 14:10:00 22.3 1.2 24.8 18.7 22 1.2 24.8 17.9 21.2 1.6 24.4 16.1 310 5 307 165 0.6 0 0.9 0.4 12/29/2006 14:20:00 23 1.7 27.1 18.7 22.7 1.7 27.1 17.9 21.9 1.7 26 17.6 310 5 310 165 0.6 0 0.9 0.4 12/29/2006 14:30:00 22.3 1.7 26.8 17.9 22 1.6 26.3 17.6 21.4 1.7 25.2 16.4 311 6 302 165 0.5 0 0.9 0.4 12/29/2006 14:40:00 23.4 2.3 30.2 17.6 23.1 2.2 29.8 17.2 22.6 2.6 30.6 16.1 312 5 316 165 0.4 0 0.7 0.2 12/29/2006 14:50:00 23.1 2.1 27.5 17.6 22.8 2.1 27.1 17.6 22.3 2.3 27.5 16.4 312 6 312 165 0.3 0.1 0.7 0.2 12/29/2006 15:00:00 24 2 28.7 18.7 23.7 2 28.7 17.9 23.2 1.8 27.1 18.3 312 6 307 165 0.2 0 0.7 0.2 12/29/2006 15:10:00 24.3 1.6 28.3 19.5 24 1.6 27.9 19.1 23.9 1.6 29.1 19.9 314 6 314 165 0.2 0 0.4 -0.1 12/29/2006 15:20:00 23 2.3 27.9 17.2 22.8 2.2 27.5 16.8 21.9 2.3 27.1 14.9 311 6 312 165 0.2 0 0.2 -0.1 12/29/2006 15:30:00 23.7 1.7 27.1 19.5 23.4 1.7 27.1 19.1 22.2 1.9 26.8 16.1 310 6 305 165 0.1 0 0.2 -0.1 12/29/2006 15:40:00 22.2 1.7 26 17.9 22 1.7 25.6 17.6 20.5 2.1 25.2 14.9 309 6 305 165 0 0 0.2 -0.1 12/29/2006 15:50:00 21.3 1.8 25.6 16.1 21 1.7 24.8 15.6 19.8 2.3 24 11.5 309 5 305 165 -0.1 0 0.2 -0.3 12/29/2006 16:00:00 17.2 2.4 22.6 12.6 17 2.4 22.1 12.2 14.8 2.8 22.1 9.1 305 6 310 165 -0.1 0 0.2 -0.3 12/29/2006 16:10:00 15.7 1.5 20.2 12.2 15.5 1.5 20.2 11.8 12.7 1.7 16.8 8.8 305 6 303 165 -0.3 0 -0.1 -0.3 12/29/2006 16:20:00 15 1.2 18.7 11.1 14.8 1.3 18.7 11.1 12.8 1.7 17.6 9.5 306 7 299 165 -0.3 0 -0.1 -0.5 12/29/2006 16:30:00 12.7 1.6 16.8 9.1 12.5 1.7 16.8 9.1 10.6 1.6 16.1 7.2 299 10 305 165 -0.5 0 -0.3 -0.8 12/29/2006 16:40:00 13.6 1.5 18.3 9.5 13.5 1.5 17.9 9.5 11 1.8 16.4 6.5 293 8 290 165 -0.4 0 -0.3 -0.5 12/29/2006 16:50:00 13.2 1.3 16.4 9.1 13 1.3 16.8 9.9 10.2 1.3 14.1 7.2 296 7 297 165 -0.5 0 -0.3 -0.8 12/29/2006 17:00:00 12.3 1.3 15.3 9.1 12.2 1.3 15.3 9.1 9.8 1.3 15.3 7.2 298 8 291 165 -0.7 0 -0.5 -0.8 12/29/2006 17:10:00 12.3 1.2 15.3 9.1 12.2 1.2 15.6 9.5 9.9 1.5 13.7 7.2 295 8 294 165 -0.7 0 -0.5 -1 12/29/2006 17:20:00 12.7 1.1 15.3 9.5 12.7 1.1 15.3 9.5 10.1 1.5 14.5 6.5 292 7 289 165 -0.6 0 -0.5 -0.8 12/29/2006 17:30:00 12.6 1.2 15.6 9.9 12.6 1.2 16.1 9.5 9.9 1.4 14.1 7.2 291 6 293 165 -0.6 0 -0.5 -0.8 12/29/2006 17:40:00 12.3 0.7 14.1 10.3 12.2 0.8 14.5 9.9 10.1 1.7 14.5 6.8 291 7 281 165 -0.6 0 -0.5 -0.8 12/29/2006 17:50:00 12 1 14.5 8.4 11.9 1 14.5 8.8 9.6 1.5 14.5 6.5 292 6 283 165 -0.7 0 -0.5 -0.8 12/29/2006 18:00:00 12 1 14.5 9.1 12 1.1 14.5 8.8 10.1 1.4 13.7 6.8 289 6 291 165 -0.8 0 -0.5 -0.8 12/29/2006 18:10:00 11.5 1 14.9 9.5 11.5 1.1 14.9 9.1 9.5 1.5 13.3 6.5 291 6 286 165 -0.8 0 -0.5 -1 12/29/2006 18:20:00 11.1 1.1 13.7 8.4 11.1 1.1 13.7 8 10.2 1.5 13.7 6.1 284 5 285 165 -0.8 0 -0.5 -1.2 12/29/2006 18:30:00 9.5 0.8 11.8 6.8 9.7 0.8 11.8 6.8 9.4 0.9 12.2 7.2 278 5 286 165 -0.6 0 -0.5 -0.8 12/29/2006 18:40:00 11.3 1.4 14.5 8.8 11.5 1.4 14.5 8.4 10.9 1.7 14.9 6.1 281 4 281 165 -0.4 0.1 -0.1 -0.8 12/29/2006 18:50:00 11.4 1.2 13.7 8 11.6 1.2 13.7 7.6 11.2 1.3 13.7 7.2 279 5 277 165 -0.2 0 -0.1 -0.5 12/29/2006 19:00:00 10.2 1.9 13.3 5.7 11.1 1.1 13.3 8 10.5 1.2 13.3 7.2 276 8 275 165 -0.3 0 -0.1 -0.5 12/29/2006 19:10:00 10.2 1.9 13.7 6.1 11.6 0.8 13.7 9.1 11.1 1 14.1 8 273 7 284 165 -0.2 0 -0.1 -0.5 12/29/2006 19:20:00 9.8 1.5 13 6.5 9.9 1.5 13.3 6.5 9.3 1.7 13 5.7 283 7 281 165 0.1 0 0.2 -0.1 12/29/2006 19:30:00 8.8 1.1 11.5 5.3 9.1 0.9 11.5 6.5 8.9 1 11.8 6.8 278 6 282 165 -0.2 0 0.2 -0.3 12/29/2006 19:40:00 10.4 0.8 12.6 7.6 10.7 0.7 12.6 8.4 10.6 0.9 13 7.2 278 4 278 165 -0.1 0 0.2 -0.3 12/29/2006 19:50:00 8.1 2.1 12.2 4.2 9.9 1.7 12.6 5.3 9.3 1.7 11.8 5.3 265 9 281 165 -0.4 0.2 -0.1 -0.8 12/29/2006 20:00:00 7.5 1 9.9 4.9 9 0.9 11.5 6.1 8.4 1 10.7 6.1 256 5 249 165 -0.8 0 -0.5 -1 12/29/2006 20:10:00 6.9 1.1 9.1 3.8 7.7 0.9 9.9 5.3 7.1 0.9 9.5 4.9 254 8 249 165 -1 0 -0.5 -1.2 12/29/2006 20:20:00 6.5 1 9.5 4.2 7 0.9 9.1 4.9 6.7 0.9 9.5 4.6 266 11 247 165 -1.2 0 -1 -1.4 12/29/2006 20:30:00 7.5 1.5 10.7 4.9 7.5 1.5 11.1 4.6 6.5 1.1 10.3 3.4 294 10 309 165 -1.2 0.1 -1 -1.4 12/29/2006 20:40:00 10 1.2 13 6.1 10 1.2 12.6 6.5 8.6 1.7 12.6 5.3 306 8 300 165 -1.6 0 -1.4 -1.9 12/29/2006 20:50:00 7.5 1.2 11.8 4.9 7.5 1.2 11.5 4.9 7 1.3 11.1 4.6 302 12 311 165 -1.4 0 -1.2 -1.4 12/29/2006 21:00:00 7.9 0.7 9.5 6.1 7.8 0.7 9.5 5.7 6.5 1 9.1 4.2 295 8 282 165 -1.4 0.1 -1.2 -1.7 12/29/2006 21:10:00 7.7 1 12.2 5.7 7.7 0.9 12.2 5.7 6.7 1 9.5 4.2 294 12 301 165 -1.6 0 -1.4 -1.9 12/29/2006 21:20:00 6.8 0.8 8.4 4.6 6.9 0.9 8.4 4.6 6.6 1.1 9.5 3.8 283 7 280 165 -2 0.1 -1.4 -2.4 12/29/2006 21:30:00 3.2 1.2 5.7 0.4 3.2 1.2 5.7 0.4 3.3 1.1 5.7 0.4 247 17 284 165 -2.2 0 -1.9 -2.6 12/29/2006 21:40:00 3.6 1.1 5.7 0.4 3.8 1.2 5.7 0.4 3.8 1.1 5.7 1.1 254 16 254 165 -2.5 0.1 -2.1 -2.8 12/29/2006 21:50:00 5.3 1.1 8 2.6 5.9 1 8 3.8 5.6 0.9 8 3.8 269 9 266 165 -2.8 0 -2.4 -2.8 12/29/2006 22:00:00 7 0.7 9.1 5.3 7 0.7 9.1 5.7 6.7 1 8.8 3.4 285 6 294 165 -2.8 0 -2.6 -3 12/29/2006 22:10:00 9.1 1 11.5 5.7 9.1 1 11.5 5.7 7.5 1 10.7 5.3 295 9 284 165 -3 0 -2.8 -3.3 12/29/2006 22:20:00 10 0.9 13 6.8 9.9 1 12.6 6.8 7.8 1 11.8 5.3 301 8 302 165 -3.1 0 -2.8 -3.3 12/29/2006 22:30:00 8.4 1 10.7 6.1 8.3 1 10.7 6.1 6.8 1.1 10.3 4.6 296 8 287 165 -3.2 0 -3 -3.3 12/29/2006 22:40:00 7.1 1 10.7 4.9 7.2 1 10.7 4.9 6.3 1.1 9.9 3.8 290 12 309 165 -3.2 0 -3 -3.5 12/29/2006 22:50:00 5.8 1 8.4 4.2 5.8 1 8.4 3.8 4.8 1 8.4 3 292 8 294 165 -3.4 0 -3.3 -3.5 12/29/2006 23:00:00 6.5 1.2 9.9 4.2 6.5 1.2 9.9 4.2 5.8 1.5 9.9 3.4 298 12 315 165 -3.2 0.1 -2.8 -3.5 12/29/2006 23:10:00 7.5 1.2 11.1 4.6 7.4 1.2 11.5 4.2 6.2 1.2 12.2 3 298 12 315 165 -3 0 -2.8 -3.3 12/29/2006 23:20:00 8.4 1.3 11.8 4.9 8.4 1.3 11.8 4.9 7.3 1.5 11.1 3.8 288 9 292 165 -2.9 0.1 -2.8 -3 12/29/2006 23:30:00 7.3 1.5 10.3 3.8 7.4 1.5 10.3 4.2 7.1 1.5 10.3 3 282 8 284 165 -3 0 -2.8 -3.3 12/29/2006 23:40:00 9.7 1.4 13.3 6.1 9.7 1.3 13.3 6.1 8.7 1.5 12.6 4.9 284 6 291 165 -3.2 0 -3 -3.3 12/29/2006 23:50:00 8.7 1 12.2 6.8 8.6 1 12.2 6.5 7.2 1.3 12.2 4.2 298 10 285 165 -3.4 0.2 -3 -3.7 12/30/2006 00:00:00 7.9 0.8 9.9 5.7 7.9 0.8 10.3 6.1 6.7 1.2 9.5 4.2 295 9 285 165 -3.7 0.1 -3.5 -3.9 12/30/2006 00:10:00 8 0.9 11.1 5.7 8 0.9 11.5 5.3 6.4 1.2 10.7 3.8 294 7 287 165 -3.7 0.1 -3.3 -3.9 12/30/2006 00:20:00 7.2 0.8 9.1 5.3 7.2 0.8 9.5 4.9 6.2 1.1 9.1 3.8 290 11 276 165 -4.2 0 -3.9 -4.4 12/30/2006 00:30:00 7.1 0.7 8.8 5.3 7.2 0.7 8.8 5.3 6.4 0.9 8.4 4.2 286 4 279 165 -4.2 0 -3.9 -4.4 12/30/2006 00:40:00 7.2 0.5 8.4 5.7 7.2 0.5 8.4 6.1 5.6 0.6 7.2 4.2 294 6 298 165 -4.3 0 -4.2 -4.4 12/30/2006 00:50:00 7.3 0.7 9.5 5.7 7.3 0.7 9.5 5.7 5.5 0.8 7.6 3.4 299 7 305 165 -4.4 0 -4.2 -4.6 12/30/2006 01:00:00 6.8 0.5 8.4 5.7 6.8 0.5 8.4 5.7 5.2 0.7 7.2 3.4 298 6 296 165 -4.5 0 -4.4 -4.6 12/30/2006 01:10:00 8.1 0.7 9.9 5.7 8.1 0.7 9.9 6.1 7 1.2 10.7 4.6 290 5 287 165 -4.5 0.1 -4.4 -4.6 12/30/2006 01:20:00 7.2 0.7 9.1 5.3 7.2 0.7 8.8 5.3 5.9 0.9 8 3.8 290 6 293 165 -4.7 0 -4.4 -4.8 12/30/2006 01:30:00 7.9 0.7 9.9 6.1 7.9 0.7 9.9 6.1 6.3 1.1 9.1 4.2 292 6 300 165 -4.8 0 -4.6 -5 12/30/2006 01:40:00 7.5 0.7 9.1 5.3 7.6 0.7 9.5 5.3 7 0.9 9.5 3.8 285 4 280 165 -4.8 0 -4.6 -5 12/30/2006 01:50:00 7.5 0.6 9.5 6.1 7.6 0.6 9.1 6.1 7 0.9 9.5 4.6 286 4 287 165 -4.8 0.1 -4.6 -5 12/30/2006 02:00:00 8.1 1.2 10.7 5.7 8.2 1.2 11.1 6.1 6.9 1 9.9 4.2 290 5 295 165 -4.8 0.1 -4.4 -5 12/30/2006 02:10:00 8.3 0.6 9.9 6.5 8.3 0.6 9.9 6.1 6.6 1 9.5 4.6 295 4 298 165 -5 0 -4.8 -5.3 12/30/2006 02:20:00 7.5 0.6 8.8 6.1 7.5 0.6 8.8 6.1 6.6 1 8.8 4.2 290 4 286 165 -4.8 0 -4.6 -5 12/30/2006 02:30:00 7.5 1 10.7 4.9 7.5 1 10.3 4.9 6.5 0.9 8.8 4.2 289 5 293 165 -5.2 0.1 -4.6 -5.5 12/30/2006 02:40:00 5.8 0.9 8 3.4 5.8 0.9 8 3.4 5.4 1.1 8.4 2.6 285 7 287 165 -5.2 0 -5 -5.5 12/30/2006 02:50:00 5.5 0.5 6.8 4.6 5.5 0.5 6.8 4.2 4.7 0.9 6.8 3 290 6 288 165 -5 0 -4.6 -5.3 12/30/2006 03:00:00 5.9 0.7 7.6 4.2 6 0.7 7.2 4.2 4.7 0.6 6.5 3 295 7 302 165 -4.9 0 -4.6 -5 12/30/2006 03:10:00 6.1 0.4 7.6 4.9 6.1 0.4 7.2 4.9 5.2 0.7 6.8 3.8 293 8 300 165 -4.8 0.1 -4.4 -5 12/30/2006 03:20:00 7.9 1.2 10.3 4.9 7.9 1.2 10.7 4.9 6.9 1.1 9.1 3.8 289 5 290 165 -4.8 0.2 -4.4 -5.3 12/30/2006 03:30:00 9.1 0.8 10.7 6.8 9.1 0.8 10.7 6.8 7.3 1 9.9 4.9 293 6 294 165 -5.4 0 -5.3 -5.7 12/30/2006 03:40:00 8.5 0.6 9.9 6.8 8.5 0.6 9.9 6.5 7.2 1 9.5 4.6 291 4 292 165 -5.5 0 -5.3 -5.7 12/30/2006 03:50:00 7.9 0.8 9.9 6.1 8 0.8 9.9 6.1 6.6 1 9.1 3.8 291 5 294 165 -5.6 0 -5.5 -5.7 12/30/2006 04:00:00 7.2 1 9.1 4.9 7.2 1 9.5 4.9 5.9 1.3 9.1 3.8 294 6 288 165 -5.9 0 -5.7 -5.9 12/30/2006 04:10:00 7.2 0.8 9.5 5.3 7.2 0.8 9.1 5.3 6 0.8 9.1 4.2 296 9 292 165 -5.9 0 -5.7 -6.1 12/30/2006 04:20:00 7.2 0.7 9.1 4.6 7.2 0.7 9.1 4.9 6.1 0.9 8.8 3.8 292 7 292 165 -5.9 0 -5.7 -6.1 12/30/2006 04:30:00 6.2 0.8 8.4 4.6 6.2 0.8 8.4 4.2 5.2 0.9 8 3 291 7 293 165 -5.7 0 -5.5 -5.9 12/30/2006 04:40:00 8.3 0.8 10.3 5.7 8.3 0.8 10.3 6.1 6.2 0.9 8.8 4.2 296 5 299 165 -5.8 0 -5.5 -5.9 12/30/2006 04:50:00 8.1 0.6 9.5 6.1 8.1 0.6 9.5 6.5 6.1 0.8 8.8 4.6 295 6 296 165 -5.8 0 -5.7 -5.9 12/30/2006 05:00:00 8.4 0.9 10.7 6.5 8.4 0.9 10.7 6.5 6.7 1.1 9.5 4.2 294 7 291 165 -6 0 -5.7 -6.4 12/30/2006 05:10:00 9.5 0.8 12.2 7.2 9.5 0.8 11.5 7.2 7.2 1 10.3 5.3 296 8 301 165 -6.1 0 -5.7 -6.4 12/30/2006 05:20:00 9.2 1 11.5 6.8 9.2 1 11.5 6.5 7.4 1.1 11.1 4.6 291 8 297 165 -6.2 0.2 -5.7 -6.6 12/30/2006 05:30:00 9.6 1.2 12.6 6.5 9.5 1.1 12.2 6.5 7.8 1.1 11.1 4.6 292 9 296 165 -6.5 0 -6.4 -6.6 12/30/2006 05:40:00 10.2 0.9 13 8.4 10.1 0.9 12.6 8.4 7.9 1.1 11.8 5.3 293 10 301 165 -6.7 0.1 -6.6 -7 12/30/2006 05:50:00 9.6 0.9 11.8 6.5 9.6 0.9 11.5 6.5 7.6 1.1 11.5 4.2 292 11 302 165 -6.9 0.1 -6.6 -7 12/30/2006 06:00:00 9.2 1 11.5 7.2 9.1 1 11.5 6.8 7.2 1.1 10.3 4.9 294 9 294 165 -6.9 0 -6.6 -7 12/30/2006 06:10:00 10.4 0.8 12.6 8.8 10.3 0.8 12.6 8.4 8 0.9 10.3 5.7 296 8 303 165 -6.9 0 -6.8 -7 12/30/2006 06:20:00 10.3 0.8 12.6 8 10.2 0.8 13 8 8.3 1.2 11.5 5.3 292 9 290 165 -6.9 0 -6.8 -7.2 12/30/2006 06:30:00 9.3 0.8 11.8 6.8 9.3 0.8 11.5 6.8 8.2 1.2 11.8 5.3 288 7 276 165 -7.2 0 -6.8 -7.4 12/30/2006 06:40:00 9 0.8 10.7 6.1 9 0.8 10.7 6.1 7.1 1.1 9.9 4.6 293 7 297 165 -7.4 0.1 -7.2 -7.6 12/30/2006 06:50:00 8 0.6 9.1 5.7 8 0.6 9.1 5.7 6.3 0.9 8.8 4.2 292 5 292 165 -7.5 0 -7.2 -7.6 12/30/2006 07:00:00 7.6 0.6 9.1 6.1 7.6 0.6 9.1 6.1 5.8 0.8 8.4 3.8 300 7 296 165 -7.4 0 -7.2 -7.6 12/30/2006 07:10:00 7.8 0.7 9.5 5.7 7.7 0.7 9.5 6.1 6 0.8 8 3.8 296 7 297 165 -7.3 0 -7 -7.4 12/30/2006 07:20:00 8.3 0.9 10.3 5.7 8.3 0.8 10.3 5.7 6.9 1 9.9 4.6 287 7 289 165 -7.5 0.1 -7.2 -7.6 12/30/2006 07:30:00 7.5 0.7 9.1 5.7 7.5 0.8 9.1 5.7 5.9 0.9 8.8 3.8 292 8 295 165 -7.5 0 -7.4 -7.6 12/30/2006 07:40:00 7.6 0.6 9.1 5.3 7.6 0.6 9.1 5.3 6 0.8 8.8 4.2 296 7 288 165 -7.4 0 -7.2 -7.6 12/30/2006 07:50:00 6.7 1 9.1 3.4 6.7 1 8.8 3 5.6 1 9.1 3.4 299 9 289 165 -7.4 0 -7.2 -7.6 12/30/2006 08:00:00 7.9 1 10.7 5.7 7.8 1 10.7 5.7 6.4 1 9.5 3.8 298 10 295 165 -7.4 0 -7.2 -7.6 12/30/2006 08:10:00 8.4 1 11.1 6.1 8.4 1 10.7 6.1 6.8 1.1 10.3 4.6 291 9 292 165 -7.5 0 -7.2 -7.6 12/30/2006 08:20:00 7.6 1 10.3 4.9 7.6 1 10.3 4.6 6.8 1.2 9.9 4.2 286 9 282 165 -7.4 0 -7.2 -7.4 12/30/2006 08:30:00 6.2 1.3 9.9 3 6.2 1.3 9.9 2.3 5.3 1.2 9.1 2.6 297 16 274 165 -7.4 0 -7.2 -7.6 12/30/2006 08:40:00 7.5 1.6 10.3 3.8 7.5 1.6 10.3 3.4 6.5 1.5 9.5 3.8 295 12 282 165 -7.4 0.1 -7.2 -7.6 12/30/2006 08:50:00 8.4 0.9 12.2 6.1 8.4 0.9 12.2 6.1 6.6 1 9.9 4.6 298 8 277 165 -7.9 0 -7.6 -8.1 12/30/2006 09:00:00 9 1 11.5 6.8 8.9 1 11.5 6.8 7.7 1 10.3 4.9 306 9 298 165 -7.9 0.1 -7.6 -8.1 12/30/2006 09:10:00 7.9 0.8 9.9 6.1 7.8 0.8 9.9 6.1 7 1.1 9.5 4.6 300 12 290 165 -7.8 0.1 -7.4 -8.1 12/30/2006 09:20:00 7 0.8 9.5 5.3 7.1 0.8 9.5 5.3 6.5 0.9 8.8 4.2 285 6 282 165 -7.7 0 -7.4 -7.9 12/30/2006 09:30:00 6.5 1.5 10.7 3 6.8 1.4 10.3 3.4 5.8 1.3 8.8 1.9 277 16 304 165 -7.5 0 -7.4 -7.9 12/30/2006 09:40:00 9.3 1.6 13.3 5.7 9.2 1.5 13.3 5.7 7.9 1.7 13 4.6 299 13 310 165 -7.3 0.2 -6.8 -7.9 12/30/2006 09:50:00 10 1.1 13 6.8 9.9 1 12.6 7.2 8.3 1.3 13 5.3 297 10 300 165 -7.1 0 -6.8 -7.4 12/30/2006 10:00:00 10.4 1.3 13.7 6.5 10.2 1.2 13.3 6.5 8.6 1.5 12.2 5.3 299 12 302 165 -7.5 0 -7.2 -7.6 12/30/2006 10:10:00 10.2 1.4 13.3 6.5 10.2 1.3 13 6.5 7.7 1.2 10.7 4.2 296 8 296 165 -7.6 0 -7.4 -7.9 12/30/2006 10:20:00 8.7 1.1 11.8 6.1 8.6 1 11.5 6.1 7 1 9.9 4.6 290 8 290 165 -7.6 0 -7.4 -7.9 12/30/2006 10:30:00 9.7 1.1 12.2 6.8 9.6 1.2 12.6 6.8 7.4 1.1 10.3 4.9 298 8 301 165 -7.6 0 -7.4 -7.6 12/30/2006 10:40:00 9.8 1 12.6 7.2 9.8 1 13 7.2 8.1 1.4 11.8 4.9 291 7 292 165 -7.6 0 -7.4 -7.9 12/30/2006 10:50:00 10.2 0.8 12.6 7.6 10.2 0.9 12.6 7.6 8.6 1.1 11.8 5.7 288 8 293 165 -7.8 0 -7.6 -8.1 12/30/2006 11:00:00 9.5 1.5 13 6.1 9.5 1.5 13 6.1 7.3 1.3 10.7 4.6 294 9 295 165 -7.8 0.1 -7.4 -8.1 12/30/2006 11:10:00 6 1 8.4 3.4 5.9 1 8.8 3.4 5.4 1.2 8.8 2.6 310 11 316 165 -7.2 0.2 -6.8 -7.6 12/30/2006 11:20:00 7.2 1.1 9.9 4.9 7.2 1.1 9.5 4.9 5.6 1 7.6 3 301 6 305 165 -7.3 0.2 -6.8 -7.6 12/30/2006 11:30:00 5 0.7 7.2 3.4 5 0.7 7.2 3.4 3.9 0.8 7.6 2.6 298 5 294 165 -7.4 0 -7.2 -7.4 12/30/2006 11:40:00 5.5 0.7 7.2 3.8 5.5 0.7 6.8 3.8 4.7 0.8 6.8 3 301 8 309 165 -7.4 0 -7.2 -7.6 12/30/2006 11:50:00 5.9 0.6 7.6 4.2 5.9 0.6 7.6 4.2 4.7 0.8 6.8 3.4 296 8 309 165 -7.3 0.1 -7 -7.6 12/30/2006 12:00:00 7.5 1.5 10.3 4.2 7.5 1.4 10.3 4.2 6.3 1.1 10.3 3.8 292 12 297 165 -7.5 0.1 -7.2 -7.9 12/30/2006 12:10:00 8.3 1 10.7 5.7 8.2 1 10.7 5.3 6.8 1 9.1 4.6 305 10 290 165 -7.1 0.2 -6.6 -7.4 12/30/2006 12:20:00 6.9 1 8.8 4.2 6.9 1 9.1 3.8 6.7 1 8.8 4.2 324 15 323 165 -6.7 0.1 -6.4 -7 12/30/2006 12:30:00 5.6 0.8 7.2 3.4 5.6 0.8 7.2 3.4 5.4 1 7.6 3.4 312 7 306 165 -6.4 0 -6.1 -6.6 12/30/2006 12:40:00 5.2 0.5 6.1 3.8 5.3 0.5 6.5 3.8 4.1 0.5 5.7 3 299 5 303 165 -6.7 0.2 -6.4 -7 12/30/2006 12:50:00 4.8 0.6 6.1 3.4 4.8 0.6 6.1 3.4 4.4 0.7 5.7 2.6 290 6 292 165 -6.9 0 -6.6 -7.2 12/30/2006 13:00:00 5.8 0.5 7.2 4.6 5.9 0.4 6.8 4.9 4.7 0.5 6.5 3.4 298 5 304 165 -7.1 0 -6.8 -7.4 12/30/2006 13:10:00 6.2 0.5 7.2 4.9 6.2 0.5 7.2 4.9 4.8 0.6 6.8 3.4 297 5 295 165 -7.3 0 -7 -7.4 12/30/2006 13:20:00 5.5 0.5 6.5 4.6 5.5 0.5 6.5 4.6 4.2 0.5 6.1 2.6 300 6 300 165 -7.1 0.1 -6.8 -7.4 12/30/2006 13:30:00 4.9 0.6 6.5 3.8 4.9 0.6 6.5 3.8 4.1 0.6 5.3 3 304 6 300 165 -7.1 0.2 -6.6 -7.4 12/30/2006 13:40:00 4.1 0.5 5.3 2.6 4.1 0.5 5.3 2.6 3.3 0.6 4.9 2.3 300 7 302 165 -6.8 0 -6.6 -7 12/30/2006 13:50:00 5.3 0.5 6.5 3.4 5.3 0.5 6.5 3.4 4.1 0.7 5.7 2.6 295 5 296 165 -7 0.2 -6.6 -7.4 12/30/2006 14:00:00 6.1 0.6 7.6 4.6 6 0.6 7.6 4.6 5.4 0.9 8 3.4 308 7 316 165 -7.3 0.1 -6.8 -7.4 12/30/2006 14:10:00 5.1 1 6.8 2.6 5.1 1 7.2 3 4.4 1 7.6 2.3 308 15 344 165 -6.6 0.2 -6.1 -7 12/30/2006 14:20:00 6.8 0.8 8.8 4.6 6.8 0.8 8.8 4.9 5.6 1 8 3 295 8 300 165 -7.2 0.2 -6.6 -7.4 12/30/2006 14:30:00 7.2 0.8 9.1 4.6 7.2 0.8 9.1 4.6 5.4 0.7 7.2 3.8 298 6 302 165 -7.5 0 -7.2 -7.6 12/30/2006 14:40:00 7.7 0.6 9.9 6.5 7.7 0.6 9.5 6.5 5.6 0.7 7.6 3.4 297 5 294 165 -7.6 0 -7.2 -7.6 12/30/2006 14:50:00 7 0.8 9.1 4.6 6.9 0.8 8.8 4.9 5.4 0.7 8 3.8 302 5 300 165 -7.8 0 -7.6 -7.9 12/30/2006 15:00:00 7.8 0.7 9.5 5.7 7.7 0.7 9.1 6.1 6.1 1 8.4 3.8 304 5 302 165 -7.8 0 -7.4 -8.1 12/30/2006 15:10:00 7.4 0.9 9.5 4.9 7.3 0.8 9.5 4.9 6.7 1 9.1 4.6 310 6 310 165 -7.4 0 -7.2 -7.6 12/30/2006 15:20:00 7.7 0.7 9.5 5.3 7.7 0.7 9.5 4.9 6.3 1 8.8 3.8 297 9 305 165 -7.4 0 -7.2 -7.6 12/30/2006 15:30:00 7.9 0.7 9.5 5.7 7.9 0.7 9.5 5.7 5.8 0.7 8.4 4.2 297 6 295 165 -7.5 0 -7.2 -7.6 12/30/2006 15:40:00 6.5 0.8 8.8 4.6 6.4 0.8 8.8 4.6 5.1 0.8 6.8 3.4 295 7 301 165 -7.4 0 -7.2 -7.6 12/30/2006 15:50:00 4.3 1.5 6.8 1.5 4.3 1.5 6.8 1.5 3.4 1 5.7 1.5 293 11 287 165 -7.4 0 -7.2 -7.6 12/30/2006 16:00:00 2.8 0.5 4.2 0.7 2.8 0.5 4.6 1.1 2.4 0.5 4.2 0.7 297 22 302 165 -7.2 0.1 -6.8 -7.4 12/30/2006 16:10:00 2.6 0.6 3.8 1.5 2.7 0.6 3.8 1.5 2.5 0.5 3.4 1.5 275 12 280 165 -7.5 0 -7.2 -7.6 12/30/2006 16:20:00 2 0.7 3.4 0.7 2.1 0.7 3 0.7 2.1 0.6 3.4 0.7 259 17 282 165 -7.8 0.2 -7.4 -8.1 12/30/2006 16:30:00 3.1 0.4 3.8 2.3 3.1 0.4 4.2 2.3 2.9 0.5 4.2 1.9 284 10 282 165 -8 0.1 -7.6 -8.5 12/30/2006 16:40:00 4.2 0.4 4.9 2.6 4.2 0.4 4.9 2.6 3.6 0.6 4.9 2.3 295 9 282 165 -8.2 0.1 -8.1 -8.5 12/30/2006 16:50:00 4.3 0.4 5.3 3.4 4.3 0.5 5.3 3.4 3.6 0.4 4.9 2.6 304 3 305 165 -8.5 0.2 -8.1 -9.1 12/30/2006 17:00:00 3.7 0.6 4.9 2.3 3.7 0.6 4.9 2.3 3 0.6 4.6 1.5 303 3 304 165 -8.9 0 -8.7 -9.1 12/30/2006 17:10:00 2.6 0.3 3.4 1.9 2.6 0.3 3.4 1.9 2.6 0.3 3.4 1.5 317 8 302 165 -8.8 0 -8.5 -9.1 12/30/2006 17:20:00 1.8 0.5 3 0.7 1.9 0.5 3 0.7 2.1 0.5 3 1.1 317 7 314 165 -8.8 0.2 -8.3 -9.1 12/30/2006 17:30:00 2.3 0.5 3.4 1.1 2.3 0.6 3.4 0.7 2.1 0.4 3.4 1.1 319 16 304 165 -8.5 0.2 -8.1 -8.9 12/30/2006 17:40:00 2.5 0.4 3.4 1.5 2.5 0.5 3.8 1.1 2.6 0.4 3.8 1.5 326 14 310 165 -9.1 0.1 -8.9 -9.3 12/30/2006 17:50:00 1.7 0.4 2.6 0.7 1.8 0.3 2.6 1.1 1.7 0.4 2.6 0.4 299 16 313 165 -9.1 0.1 -8.7 -9.3 12/30/2006 18:00:00 2.6 0.3 3 1.9 2.6 0.3 3.4 1.9 2.5 0.4 3.4 1.1 287 5 282 165 -8.8 0.1 -8.3 -9.1 12/30/2006 18:10:00 1.6 0.6 2.6 0.4 1.7 0.5 3 0.4 1.8 0.6 3 0.4 272 12 275 165 -8.3 0 -8.1 -8.5 12/30/2006 18:20:00 2.3 0.4 3.4 1.1 2.4 0.4 3.4 1.1 2.4 0.3 3 1.5 282 5 280 165 -8.7 0.1 -8.5 -9.1 12/30/2006 18:30:00 2.8 0.3 3.4 1.9 2.9 0.3 3.4 1.9 2.9 0.3 3.8 2.3 281 5 285 165 -8.9 0 -8.7 -9.1 12/30/2006 18:40:00 3.2 0.3 3.8 2.3 3.2 0.3 4.2 2.6 2.9 0.6 4.2 1.5 289 5 282 165 -8.9 0 -8.5 -9.1 12/30/2006 18:50:00 2.4 0.4 3 1.1 2.4 0.4 3 1.1 2.1 0.5 3.8 1.1 287 7 298 165 -8.7 0 -8.5 -8.9 12/30/2006 19:00:00 0.8 0.5 1.9 0.4 0.9 0.5 1.9 0.4 1.2 0.4 1.9 0.4 282 16 277 165 -8.3 0.1 -8.1 -8.5 12/30/2006 19:10:00 0.8 0.4 1.9 0.4 0.9 0.4 1.9 0.4 1.2 0.5 2.3 0.4 221 27 203 165 -8 0 -7.6 -8.3 12/30/2006 19:20:00 1.9 0.6 3 0.4 1.9 0.6 3 0.4 1.9 0.8 3 0.4 181 13 178 165 -8.1 0.1 -7.6 -8.3 12/30/2006 19:30:00 2 0.6 3.4 0.7 1.9 0.6 3 0.7 2.1 0.7 3.8 0.7 168 5 175 165 -8.1 0 -8.1 -8.5 12/30/2006 19:40:00 0.5 0.3 1.9 0.4 0.5 0.3 1.5 0.4 0.5 0.3 1.5 0.4 177 5 167 165 -8.3 0 -8.1 -8.5 12/30/2006 19:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.7 0.4 183 1 165 165 -9.1 0.3 -8.5 -9.7 12/30/2006 20:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.5 0.2 1.1 0.4 240 58 165 165 -9.7 0 -9.5 -9.7 12/30/2006 20:10:00 0.6 0.4 1.9 0.4 0.7 0.4 1.9 0.4 0.8 0.4 1.5 0.4 194 86 147 165 -8.9 0.5 -8.1 -9.7 12/30/2006 20:20:00 0.7 0.4 2.6 0.4 0.7 0.4 1.9 0.4 0.8 0.3 1.5 0.4 152 10 168 165 -8.3 0.1 -8.1 -8.7 12/30/2006 20:30:00 0.4 0.2 1.1 0.4 0.4 0.2 1.5 0.4 0.4 0.2 1.1 0.4 161 7 165 165 -8.5 0 -8.3 -8.7 12/30/2006 20:40:00 0.8 0.5 1.9 0.4 0.8 0.5 1.9 0.4 0.8 0.5 1.9 0.4 161 3 166 165 -8.6 0 -8.5 -8.7 12/30/2006 20:50:00 0.4 0.1 0.7 0.4 0.4 0 0.7 0.4 0.4 0 0.4 0.4 162 6 163 165 -8.8 0 -8.5 -9.1 12/30/2006 21:00:00 1.3 0.6 2.3 0.4 1.4 0.7 2.6 0.4 1.6 0.5 2.6 0.4 277 22 282 165 -8.8 0 -8.5 -9.1 12/30/2006 21:10:00 1.2 0.5 2.3 0.4 1.3 0.5 2.3 0.4 1.3 0.4 2.3 0.4 272 36 308 165 -9.1 0 -8.7 -9.3 12/30/2006 21:20:00 1.4 0.7 3 0.4 1.5 0.7 3 0.4 1.6 0.5 2.6 0.4 279 26 300 165 -8.8 0.2 -8.5 -9.3 12/30/2006 21:30:00 0.7 0.4 1.5 0.4 0.8 0.4 1.9 0.4 0.9 0.4 1.9 0.4 285 10 310 165 -9.1 0 -8.9 -9.3 12/30/2006 21:40:00 1.7 0.5 2.6 0.4 1.7 0.5 2.6 0.4 1.8 0.6 3 0.7 298 18 311 165 -9.1 0.1 -8.9 -9.7 12/30/2006 21:50:00 3.2 0.5 4.2 1.9 3.2 0.5 4.2 2.3 3.1 0.4 4.2 2.3 317 8 314 165 -9.6 0 -9.3 -9.7 12/30/2006 22:00:00 1.3 0.9 3 0.4 1.3 0.8 3 0.4 1.5 0.9 3 0.4 335 6 341 165 -9.6 0 -9.3 -9.7 12/30/2006 22:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0.1 1.1 0.4 320 17 165 165 -9.1 0.2 -8.7 -9.3 12/30/2006 22:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.7 0.4 302 0 165 165 -9 0.1 -8.7 -9.1 12/30/2006 22:30:00 1.7 0.8 3 0.4 1.8 0.9 3 0.4 1.9 0.7 3.4 0.4 285 11 292 165 -9.2 0.1 -8.9 -9.7 12/30/2006 22:40:00 2.8 0.4 3.4 1.5 2.9 0.4 3.8 1.5 2.1 0.4 3.4 0.7 300 5 296 165 -9.6 0 -9.3 -9.7 12/30/2006 22:50:00 1.5 0.9 3.4 0.4 1.6 0.8 3.4 0.4 1.6 0.6 3 0.4 303 5 307 165 -9.4 0.2 -8.9 -9.7 12/30/2006 23:00:00 1.4 0.5 2.6 0.4 1.4 0.5 2.6 0.4 1.5 0.5 2.6 0.4 317 12 315 165 -9.3 0.1 -8.9 -9.5 12/30/2006 23:10:00 1.3 0.6 2.6 0.4 1.1 0.5 2.3 0.4 1.5 0.5 2.6 0.4 3 13 2 165 -9.2 0 -8.9 -9.5 12/30/2006 23:20:00 1.8 0.2 2.3 1.5 1.6 0.3 2.3 0.7 1.9 0.2 2.6 1.1 10 3 5 165 -9.6 0.1 -9.3 -9.7 12/30/2006 23:30:00 1.8 0.3 2.3 1.1 1.4 0.3 1.9 0.7 1.9 0.2 2.3 1.5 10 0 11 165 -9.8 0 -9.7 -10.2 12/30/2006 23:40:00 0.8 0.4 1.5 0.4 0.7 0.3 1.5 0.4 1.4 0.2 1.9 1.1 23 7 10 165 -9.9 0 -9.7 -10.2 12/30/2006 23:50:00 1 0.2 1.5 0.4 0.8 0.3 1.5 0.4 1.5 0.2 1.9 1.1 4 10 15 165 -9.7 0.1 -9.3 -10.2 12/31/2006 00:00:00 0.9 0.4 1.9 0.4 1.1 0.4 1.9 0.4 1.4 0.3 1.9 0.7 335 5 328 165 -9.4 0 -9.3 -9.7 12/31/2006 00:10:00 1.2 0.4 1.9 0.4 1.3 0.5 1.9 0.4 1.5 0.3 2.3 0.7 321 6 317 165 -9.3 0 -9.1 -9.7 12/31/2006 00:20:00 0.6 0.3 1.5 0.4 0.6 0.4 1.9 0.4 0.7 0.4 1.9 0.4 308 0 309 165 -9.3 0 -9.1 -9.7 12/31/2006 00:30:00 0.4 0 0.4 0.4 0.4 0 0.7 0.4 0.4 0.1 1.1 0.4 308 0 165 165 -9.2 0.1 -8.9 -9.5 12/31/2006 00:40:00 0.5 0.3 1.5 0.4 0.6 0.3 1.5 0.4 0.9 0.3 1.9 0.4 286 15 299 165 -9.1 0 -8.9 -9.3 12/31/2006 00:50:00 0.4 0.1 0.7 0.4 0.4 0.2 1.1 0.4 0.5 0.3 1.5 0.4 296 0 296 165 -9.5 0.3 -9.1 -10.2 12/31/2006 01:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 296 0 165 165 -10.4 0 -10.2 -10.8 12/31/2006 01:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0.1 1.1 0.4 296 0 165 165 -10.7 0.1 -10.6 -11 12/31/2006 01:20:00 0.4 0.1 0.7 0.4 0.4 0.1 0.7 0.4 0.9 0.4 1.5 0.4 296 0 296 165 -10.4 0.3 -9.7 -11 12/31/2006 01:30:00 0.4 0 0.4 0.4 0.4 0.1 0.7 0.4 0.8 0.2 1.1 0.4 296 0 165 165 -9.7 0.1 -9.7 -10.2 12/31/2006 01:40:00 0.5 0.2 1.1 0.4 0.4 0.2 1.1 0.4 1.1 0.4 1.9 0.4 336 32 2 165 -9.7 0.1 -9.5 -10.2 12/31/2006 01:50:00 0.7 0.3 1.5 0.4 0.8 0.3 1.5 0.4 1.5 0.2 1.9 1.1 2 0 2 165 -9.6 0 -9.3 -9.7 12/31/2006 02:00:00 0.8 0.3 1.5 0.4 0.8 0.3 1.5 0.4 1.7 0.2 1.9 1.1 2 0 2 165 -9.5 0 -9.3 -9.7 12/31/2006 02:10:00 0.4 0 0.4 0.4 0.4 0 0.7 0.4 1 0.2 1.5 0.4 2 0 165 165 -9.2 0.1 -8.9 -9.7 12/31/2006 02:20:00 0.4 0 0.4 0.4 0.4 0.1 0.7 0.4 0.8 0.3 1.5 0.4 2 0 165 165 -9.1 0 -8.9 -9.1 12/31/2006 02:30:00 0.4 0.1 1.1 0.4 0.6 0.3 1.1 0.4 1 0.2 1.5 0.4 356 3 1 165 -9 0 -8.9 -9.1 12/31/2006 02:40:00 0.4 0 0.7 0.4 0.4 0.1 0.7 0.4 0.4 0.1 0.7 0.4 357 66 116 165 -8.9 0.1 -8.5 -9.1 12/31/2006 02:50:00 0.4 0.1 0.7 0.4 0.4 0.2 1.1 0.4 0.5 0.3 1.5 0.4 93 36 17 165 -8.8 0 -8.5 -8.9 12/31/2006 03:00:00 0.4 0 0.7 0.4 0.4 0.1 1.1 0.4 0.4 0.2 1.1 0.4 17 0 17 165 -8.7 0.1 -8.5 -8.9 12/31/2006 03:10:00 0.4 0 0.4 0.4 0.4 0 0.7 0.4 0.5 0.2 1.1 0.4 17 0 165 165 -8.7 0 -8.5 -8.9 12/31/2006 03:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.5 0.2 1.1 0.4 17 0 165 165 -8.8 0 -8.5 -8.9 12/31/2006 03:30:00 0.4 0 0.4 0.4 0.4 0.1 0.7 0.4 0.4 0.2 1.1 0.4 17 0 165 165 -8.8 0 -8.5 -8.9 12/31/2006 03:40:00 0.4 0 0.4 0.4 0.4 0 0.7 0.4 0.4 0.1 0.7 0.4 17 0 165 165 -8.9 0.1 -8.7 -9.1 12/31/2006 03:50:00 0.4 0.1 0.7 0.4 0.5 0.2 1.1 0.4 0.6 0.2 1.1 0.4 57 20 37 165 -8.9 0 -8.7 -9.1 12/31/2006 04:00:00 0.4 0 0.4 0.4 0.4 0.1 0.7 0.4 0.4 0.2 0.7 0.4 82 0 165 165 -8.8 0 -8.5 -8.9 12/31/2006 04:10:00 0.7 0.4 1.5 0.4 0.8 0.4 1.9 0.4 1.2 0.4 2.3 0.4 64 12 46 165 -8.7 0 -8.5 -8.9 12/31/2006 04:20:00 0.8 0.3 1.5 0.4 1.1 0.2 1.5 0.4 1.6 0.2 2.3 1.1 48 3 46 165 -8.9 0 -8.5 -9.1 12/31/2006 04:30:00 1.8 0.8 3 0.4 1.9 0.7 3.4 0.4 2.4 0.5 3.4 1.1 49 4 42 165 -9 0 -8.7 -9.1 12/31/2006 04:40:00 3.1 0.2 3.8 2.6 3.2 0.2 3.8 2.6 3.3 0.2 3.8 3 32 4 28 165 -9.2 0 -8.9 -9.5 12/31/2006 04:50:00 3.5 0.2 4.2 3 3.5 0.2 4.2 3 3.7 0.3 4.2 3 34 2 34 165 -9.4 0 -9.3 -9.7 12/31/2006 05:00:00 3.5 0.2 4.2 3 3.5 0.2 3.8 3 3.8 0.2 4.2 3 23 4 20 165 -9.4 0 -9.3 -9.7 12/31/2006 05:10:00 3.6 0.3 4.2 3 3.5 0.3 4.2 3 3.7 0.3 4.2 3 21 4 20 165 -9.4 0 -9.3 -9.7 12/31/2006 05:20:00 3.9 0.3 4.6 3 3.8 0.5 4.6 2.3 4 0.3 4.6 3 23 7 28 165 -9.4 0 -9.1 -9.7 12/31/2006 05:30:00 3.7 0.3 4.2 3 3.7 0.3 4.2 3 3.9 0.3 4.6 3 30 4 33 165 -9.1 0.1 -8.9 -9.3 12/31/2006 05:40:00 2.7 0.3 3.4 1.5 2.7 0.4 3.4 1.5 2.8 0.3 3.4 2.3 41 5 29 165 -8.9 0 -8.5 -9.1 12/31/2006 05:50:00 2.8 0.3 3.8 1.9 2.9 0.3 3.8 1.9 3 0.3 3.8 2.3 45 5 58 165 -8.7 0 -8.5 -8.9 12/31/2006 06:00:00 3.4 0.2 3.8 3 3.4 0.2 3.8 3 3.6 0.2 4.2 3 33 2 36 165 -8.7 0 -8.5 -8.9 12/31/2006 06:10:00 3.1 0.2 3.4 2.6 3.2 0.2 3.8 2.6 3.3 0.2 3.8 2.6 34 1 34 165 -8.7 0 -8.5 -8.9 12/31/2006 06:20:00 3.4 0.3 4.2 2.6 3.4 0.3 4.2 2.6 3.6 0.2 4.2 3 34 1 32 165 -8.7 0 -8.5 -8.9 12/31/2006 06:30:00 3.7 0.3 4.6 3 3.8 0.3 4.6 3 3.9 0.4 4.6 2.6 29 2 29 165 -8.5 0 -8.3 -8.7 12/31/2006 06:40:00 4.5 0.3 5.3 3.8 4.5 0.3 5.3 3.8 4.6 0.3 5.7 3.8 29 2 31 165 -8.5 0 -8.3 -8.7 12/31/2006 06:50:00 4.7 0.3 5.3 3.8 4.7 0.3 5.3 3.8 4.8 0.3 5.7 4.2 27 3 25 165 -8.5 0 -8.3 -8.5 12/31/2006 07:00:00 3.8 0.4 4.9 2.6 3.8 0.4 4.9 2.6 4 0.4 5.3 3 31 3 31 165 -8.2 0 -8.1 -8.5 12/31/2006 07:10:00 3.2 0.3 4.2 2.6 3.2 0.3 3.8 2.6 3.4 0.3 4.2 2.6 34 4 31 165 -8.1 0 -8.1 -8.3 12/31/2006 07:20:00 3.1 0.2 3.8 2.6 3.1 0.2 3.8 2.6 3.3 0.2 3.8 2.6 34 2 31 165 -8 0 -7.9 -8.3 12/31/2006 07:30:00 3.7 0.3 4.6 3 3.7 0.3 4.6 3 3.8 0.2 4.6 3 31 2 29 165 -8 0 -7.6 -8.1 12/31/2006 07:40:00 3.8 0.2 4.2 3.4 3.8 0.2 4.2 3.4 3.9 0.2 4.6 3.4 30 3 32 165 -7.9 0 -7.6 -8.1 12/31/2006 07:50:00 3.5 0.3 4.2 3 3.5 0.3 4.2 2.6 3.6 0.3 4.6 3 29 2 31 165 -7.9 0 -7.6 -8.1 12/31/2006 08:00:00 3.4 0.2 3.8 2.6 3.4 0.2 3.8 2.6 3.6 0.2 4.2 3 31 4 28 165 -7.9 0 -7.6 -8.1 12/31/2006 08:10:00 3.3 0.3 3.8 2.3 3.3 0.3 3.8 2.3 3.5 0.3 4.2 3 33 3 39 165 -7.9 0 -7.6 -8.1 12/31/2006 08:20:00 3.6 0.4 4.6 2.6 3.6 0.4 4.6 2.6 3.7 0.4 4.6 3 34 5 29 165 -7.8 0 -7.6 -7.9 12/31/2006 08:30:00 4.6 0.2 5.3 4.2 4.5 0.2 5.3 4.2 4.7 0.3 5.3 4.2 27 4 25 165 -7.8 0 -7.6 -7.9 12/31/2006 08:40:00 4.6 0.3 5.3 3.8 4.6 0.3 5.3 3.4 4.7 0.3 5.7 3.8 29 5 26 165 -7.6 0 -7.4 -8.1 12/31/2006 08:50:00 4.9 0.2 5.3 4.2 4.9 0.3 5.7 4.2 5.1 0.3 5.7 4.6 31 3 25 165 -7.6 0 -7.4 -7.6 12/31/2006 09:00:00 5.7 0.4 7.2 4.9 5.8 0.4 7.2 4.9 6 0.3 6.8 4.9 26 3 20 165 -7.5 0 -7.4 -7.6 12/31/2006 09:10:00 6.7 0.5 8 5.3 6.6 0.6 8 4.6 7 0.5 8 5.7 21 3 23 165 -7.5 0 -7.2 -7.6 12/31/2006 09:20:00 6.2 0.5 7.2 5.3 5.5 0.7 7.2 3.8 6.5 0.5 7.6 5.3 15 4 16 165 -7.3 0 -7 -7.4 12/31/2006 09:30:00 5.2 0.5 6.5 3.4 4.9 0.6 6.5 3 5.3 0.5 6.8 4.2 18 5 31 165 -7.1 0 -6.8 -7.2 12/31/2006 09:40:00 4.5 0.3 5.3 3.8 4.6 0.4 5.7 3.4 4.9 0.4 6.1 4.2 21 4 22 165 -6.9 0.1 -6.6 -7.2 12/31/2006 09:50:00 4.8 0.3 5.7 3.8 4.9 0.3 5.7 3.8 5.1 0.4 6.1 4.2 24 5 26 165 -6.8 0 -6.6 -7 12/31/2006 10:00:00 4.7 0.4 5.3 3.8 4.8 0.4 5.7 3.4 5.1 0.4 5.7 4.2 21 4 25 165 -6.8 0 -6.6 -6.8 12/31/2006 10:10:00 5 0.4 5.7 4.2 4.5 0.7 5.7 2.3 5.3 0.3 6.1 4.2 14 4 19 165 -6.6 0 -6.4 -6.8 12/31/2006 10:20:00 5.1 0.3 5.7 4.2 4.6 1 6.1 2.3 5.3 0.4 6.5 4.2 17 8 2 165 -6.5 0.1 -6.1 -6.8 12/31/2006 10:30:00 5.8 0.5 6.8 4.6 5.9 0.5 7.2 4.6 6.2 0.5 7.2 4.9 25 4 25 165 -6.1 0 -5.7 -6.4 12/31/2006 10:40:00 4.8 0.4 5.7 3.8 4.7 0.5 5.7 3 5 0.4 6.1 4.2 20 5 23 165 -6.1 0 -5.9 -6.4 12/31/2006 10:50:00 4 0.4 4.9 3 3.9 0.4 4.9 2.6 4.2 0.3 4.9 3 24 6 22 165 -6.1 0 -5.9 -6.4 12/31/2006 11:00:00 3.3 0.3 3.8 2.6 3.3 0.3 3.8 2.6 3.6 0.3 4.2 3 32 4 32 165 -6 0.1 -5.7 -6.4 12/31/2006 11:10:00 4.1 0.5 4.9 3 3.9 0.4 4.9 3 4.4 0.5 5.3 3.4 20 5 16 165 -5.8 0 -5.7 -5.9 12/31/2006 11:20:00 4.2 0.2 4.9 3.8 4.2 0.2 4.9 3.8 4.5 0.3 4.9 3.8 23 5 23 165 -5.8 0 -5.5 -5.7 12/31/2006 11:30:00 3.6 0.4 4.6 2.3 3.7 0.4 4.6 2.3 3.9 0.4 4.6 2.6 30 4 34 165 -5.5 0.1 -5.3 -5.7 12/31/2006 11:40:00 3.5 0.2 4.2 3 3.6 0.2 4.2 3 3.7 0.2 4.6 3 25 3 26 165 -5.3 0 -5 -5.5 12/31/2006 11:50:00 3.7 0.4 4.6 3 3.6 0.4 4.6 2.6 3.9 0.3 4.6 3 18 3 18 165 -5.2 0 -5 -5.3 12/31/2006 12:00:00 4.8 0.4 5.7 4.2 4.7 0.4 5.7 3.8 4.9 0.4 6.1 4.2 19 3 21 165 -5.2 0 -5 -5.3 12/31/2006 12:10:00 5.6 0.4 6.5 4.9 5 0.5 6.1 3 5.8 0.5 6.8 4.6 15 4 6 165 -5 0 -4.8 -5.3 12/31/2006 12:20:00 6 0.4 6.8 4.9 5 0.5 6.5 3.4 6.3 0.4 7.2 4.9 13 2 15 165 -5 0 -4.8 -5.3 12/31/2006 12:30:00 5.9 0.3 6.5 4.9 5.7 0.4 6.8 4.6 6.2 0.5 6.8 4.6 18 2 16 165 -4.9 0 -4.6 -5 12/31/2006 12:40:00 6.5 0.4 7.6 5.3 6.2 0.5 7.2 4.9 6.7 0.4 7.6 5.3 18 3 15 165 -4.8 0 -4.4 -5 12/31/2006 12:50:00 6.1 0.3 7.2 5.3 6.1 0.4 7.2 4.2 6.2 0.4 7.2 4.2 21 3 23 165 -4.6 0 -4.4 -4.6 12/31/2006 13:00:00 6.3 0.5 7.6 5.3 6.1 0.6 7.6 4.6 6.5 0.5 8 4.9 18 3 25 165 -4.4 0 -4.4 -4.6 12/31/2006 13:10:00 7.1 0.6 9.1 5.7 6.1 0.8 8.8 4.2 7.2 0.7 9.1 5.3 14 3 18 165 -4.3 0 -4.2 -4.4 12/31/2006 13:20:00 7 0.6 8.4 5.7 5.9 1 8 3.4 7.1 0.7 8.4 4.9 13 4 19 165 -4 0 -3.9 -4.4 12/31/2006 13:30:00 7.7 0.6 9.1 6.1 7.2 0.8 8.8 4.9 7.7 0.6 9.1 5.3 17 4 21 165 -3.9 0 -3.5 -4.2 12/31/2006 13:40:00 8.5 0.6 9.9 6.1 8 0.8 9.5 4.6 8.3 0.8 9.9 5.7 19 5 17 165 -3.7 0.1 -3.5 -3.9 12/31/2006 13:50:00 7.6 0.9 9.5 4.9 7.1 0.9 9.5 4.9 7.5 0.9 9.5 5.3 18 6 15 165 -3.5 0 -3.3 -3.5 12/31/2006 14:00:00 7.6 0.8 10.3 5.3 6.9 1.1 9.9 4.2 7.5 0.8 9.5 5.7 16 7 20 165 -3.3 0 -3 -3.5 12/31/2006 14:10:00 6.1 0.7 8.4 4.2 6 0.8 8.4 3.4 6.1 0.8 8 4.6 25 9 30 165 -3.2 0 -3 -3.3 12/31/2006 14:20:00 5.4 0.7 6.8 3.4 5.5 0.7 7.2 3.4 5.3 0.8 7.2 3.4 41 7 32 165 -3.2 0 -2.8 -3.5 12/31/2006 14:30:00 4.9 0.6 6.5 3.4 5 0.6 6.5 3 5 0.6 6.8 3.4 28 6 26 165 -3 0 -2.8 -3.3 12/31/2006 14:40:00 6.1 1.3 10.3 3.4 6.2 1.3 10.3 3.4 5.9 1.3 9.9 3.4 48 12 48 165 -2.8 0.2 -2.4 -3.3 12/31/2006 14:50:00 6.9 1.2 9.5 3.4 6.9 1.1 9.5 3.8 6.6 1.1 9.1 3.8 50 10 66 165 -2.4 0 -2.1 -2.6 12/31/2006 15:00:00 7.1 1.1 9.9 4.6 7.3 1.1 9.9 4.6 7 1 9.5 4.6 59 9 63 165 -2.5 0 -2.1 -2.6 12/31/2006 15:10:00 7.7 1.4 10.7 4.2 7.8 1.3 11.5 4.2 7.4 1.3 10.7 4.2 54 9 50 165 -2.4 0 -2.1 -2.6 12/31/2006 15:20:00 7.2 1.3 9.9 4.6 7.3 1.3 10.3 4.6 7.1 1.2 9.9 4.6 56 10 68 165 -2.2 0 -2.1 -2.4 12/31/2006 15:30:00 9.1 1.3 11.8 4.9 9.1 1.4 11.8 4.9 8.7 1.3 11.5 4.9 51 9 46 165 -2.2 0 -2.1 -2.4 12/31/2006 15:40:00 8.5 1.3 12.6 5.3 8.5 1.4 12.6 4.9 8.3 1.3 13 5.3 49 9 48 165 -2.2 0 -1.9 -2.4 12/31/2006 15:50:00 8.7 1.3 11.8 5.3 8.7 1.4 12.2 5.3 8.3 1.2 11.5 5.3 44 8 49 165 -2.2 0 -1.9 -2.4 12/31/2006 16:00:00 9 1.4 12.6 5.3 8.9 1.5 12.6 5.3 8.5 1.3 11.8 5.7 44 11 52 165 -2.1 0 -1.9 -2.4 12/31/2006 16:10:00 9.9 1.8 14.5 5.7 9.8 1.8 14.1 5.3 9.6 1.9 14.9 4.9 36 9 42 165 -2.2 0 -1.9 -2.4 12/31/2006 16:20:00 9.2 1.5 13.7 6.5 9.2 1.5 13.3 6.1 9 1.7 13.7 5.3 46 9 44 165 -2.2 0 -1.9 -2.4 12/31/2006 16:30:00 10.3 1.6 14.5 6.5 10.3 1.7 14.9 6.1 9.9 1.7 14.9 6.5 42 9 45 165 -2.2 0 -1.9 -2.4 12/31/2006 16:40:00 11 1.5 14.5 6.8 10.9 1.6 14.5 6.1 10.6 1.5 14.9 6.8 39 10 37 165 -2.3 0 -2.1 -2.6 12/31/2006 16:50:00 11.1 1.5 14.1 7.6 11 1.6 14.1 7.2 10.9 1.5 14.9 7.2 38 8 47 165 -2.3 0 -2.1 -2.6 12/31/2006 17:00:00 11.4 1.6 15.6 6.8 11.3 1.6 16.1 6.8 11.2 1.7 14.9 6.8 32 7 25 165 -2.2 0 -2.1 -2.6 12/31/2006 17:10:00 11.4 1.5 14.9 7.6 11.3 1.5 14.9 6.8 11 1.5 15.3 7.6 30 8 30 165 -2.1 0 -1.9 -2.4 12/31/2006 17:20:00 11.9 1.5 14.9 7.2 11.8 1.5 15.3 7.2 11.8 1.5 15.3 7.6 33 8 32 165 -2 0 -1.7 -2.1 12/31/2006 17:30:00 12.3 1.5 15.6 8.4 12.2 1.6 15.6 7.6 12.1 1.6 15.6 8 30 6 31 165 -1.9 0 -1.7 -2.1 12/31/2006 17:40:00 11.6 1.6 15.6 7.2 11.5 1.7 15.3 5.7 11.2 1.6 15.6 7.2 28 8 27 165 -1.8 0 -1.4 -1.9 12/31/2006 17:50:00 12.2 1.5 15.6 7.6 11.8 1.7 15.6 6.5 11.8 1.5 15.6 7.6 23 10 31 165 -1.6 0 -1.4 -1.9 12/31/2006 18:00:00 12.1 1.8 16.8 7.2 11.6 2.1 16.8 5.7 11.5 1.8 16.1 7.6 20 10 33 165 -1.5 0 -1.2 -1.7 12/31/2006 18:10:00 10.3 1.8 14.5 5.3 9.7 2.2 14.5 4.2 9.8 1.6 14.1 6.1 17 9 23 165 -1.5 0 -1.2 -1.7 12/31/2006 18:20:00 9.5 1.5 13 6.1 8.3 1.6 12.6 4.2 9.3 1.3 13 6.1 9 9 18 165 -1.6 0 -1.4 -1.9 12/31/2006 18:30:00 11.7 1.5 15.6 8 11.4 1.7 15.3 7.6 11.1 1.4 15.3 7.6 22 10 31 165 -1.8 0.1 -1.4 -1.9 12/31/2006 18:40:00 10 1.5 13 6.1 8.7 1.5 12.2 4.2 9.7 1.4 13 6.5 10 9 12 165 -1.7 0 -1.4 -1.9 12/31/2006 18:50:00 9.7 1.3 13.7 6.5 8 1.6 12.2 3.8 9.4 1.4 13.7 6.5 7 7 6 165 -1.7 0 -1.4 -1.9 12/31/2006 19:00:00 10.1 1.3 13.3 7.2 8.3 1.6 12.2 3.4 10 1.3 13.3 7.2 6 8 10 165 -1.6 0 -1.4 -1.7 12/31/2006 19:10:00 10.4 2.1 15.3 6.1 9.4 2.3 15.3 4.6 9.8 1.8 16.1 6.1 15 12 22 165 -1.5 0 -1.4 -1.7 12/31/2006 19:20:00 11.8 2.4 16.8 5.3 11.3 2.6 16.4 4.9 11.5 2.4 16.8 5.3 21 9 34 165 -1.2 0.1 -0.8 -1.7 12/31/2006 19:30:00 12.7 1.5 15.6 7.6 12.4 1.5 15.6 7.2 12.2 1.5 16.1 7.6 23 8 22 165 -0.8 0 -0.5 -1.2 12/31/2006 19:40:00 13.3 1.8 17.2 8.4 12.8 2 16.8 8 12.8 1.9 17.2 8.4 18 9 20 165 -0.6 0 -0.5 -0.8 12/31/2006 19:50:00 12.7 1.5 15.6 8.8 10.9 2.1 15.3 6.1 12.2 1.6 15.6 8 8 8 21 165 -0.7 0.1 -0.5 -1 12/31/2006 20:00:00 12.1 1.7 17.9 8.4 10.2 2.1 17.2 5.7 11.6 1.7 17.6 8 6 9 18 165 -0.9 0 -0.8 -1 12/31/2006 20:10:00 12 1.7 15.3 8 9.8 2.2 14.5 5.3 11.4 1.6 15.3 7.2 6 8 14 165 -0.8 0 -0.5 -0.8 12/31/2006 20:20:00 13.9 2.1 18.3 9.5 12.2 2.8 17.6 6.1 13.1 2 18.3 8.8 9 9 16 165 -0.6 0 -0.5 -0.8 12/31/2006 20:30:00 13.5 1.7 17.2 9.5 11.3 2.3 16.4 6.1 13 1.7 17.6 9.1 6 9 5 165 -0.5 0 -0.3 -0.8 12/31/2006 20:40:00 13.2 1.5 16.4 9.1 11.1 2 16.1 6.5 12.6 1.5 16.4 8 6 9 358 165 -0.6 0 -0.5 -0.8 12/31/2006 20:50:00 14 1.7 18.7 9.5 12.5 1.9 17.9 6.8 13.3 1.7 17.6 9.1 10 10 16 165 -0.7 0 -0.5 -0.8 12/31/2006 21:00:00 12.7 1.7 16.4 8 10.8 2.3 15.6 6.1 12.2 1.8 16.4 8.4 7 9 4 165 -0.8 0 -0.5 -1 12/31/2006 21:10:00 13.1 2 17.9 7.6 11.1 1.9 16.4 6.5 12.8 1.8 17.2 8.4 7 9 11 165 -0.8 0 -0.5 -1 12/31/2006 21:20:00 16 1.6 19.5 11.5 14.3 2.1 19.5 9.5 15.4 1.7 18.7 10.7 10 8 8 165 -0.9 0.1 -0.5 -1 12/31/2006 21:30:00 13 1.5 16.8 8.4 11.2 2 16.1 6.5 12.7 1.5 17.6 8.8 9 9 2 165 -0.9 0 -0.8 -1.2 12/31/2006 21:40:00 12.7 1.5 16.1 8.4 10.6 1.9 15.6 6.5 12.3 1.5 16.1 8.8 7 9 10 165 -1 0 -0.8 -1.2 12/31/2006 21:50:00 12.9 1.2 16.4 10.3 10.2 1.5 15.3 6.5 12.6 1.3 16.1 9.1 4 8 4 165 -1.2 0 -1 -1.2 12/31/2006 22:00:00 13.8 1.7 18.7 8.4 10.9 2.3 17.2 5.3 13.4 1.7 18.3 9.5 4 9 4 165 -1.2 0 -1.2 -1.4 12/31/2006 22:10:00 13 1.8 17.6 8.4 10.1 2.1 16.8 5.7 12.6 1.8 17.6 8.4 2 8 355 165 -1.2 0 -1.2 -1.4 12/31/2006 22:20:00 12.6 1.7 16.8 8 10.2 1.8 16.1 6.1 12.3 1.5 17.2 8 0 11 346 165 -1.3 0 -1.2 -1.4 12/31/2006 22:30:00 13.1 1.8 18.7 8.8 10.4 2.2 17.6 6.5 12.9 1.6 17.9 9.1 358 9 12 165 -1.4 0 -1.2 -1.4 12/31/2006 22:40:00 12.7 1.7 17.2 8.8 10.7 2 16.4 6.1 12.2 1.8 17.2 8.4 355 12 352 165 -1.5 0 -1.2 -1.9 12/31/2006 22:50:00 12.8 1.4 16.4 9.5 11.9 1.8 16.8 7.6 12.2 1.5 15.6 8.4 346 7 341 165 -2 0.1 -1.7 -2.4 12/31/2006 23:00:00 12.9 2 18.3 7.6 11.6 2.3 18.3 5.7 12.4 1.9 17.6 8 346 9 340 165 -2.3 0 -2.1 -2.6 12/31/2006 23:10:00 13.7 1.9 19.5 9.5 12 1.8 17.2 8.4 13.2 1.8 18.3 9.1 347 10 351 165 -2.5 0 -2.4 -2.6 12/31/2006 23:20:00 16 1.9 21 11.1 14.1 2.4 19.9 8 15.6 1.9 20.6 10.3 346 8 355 165 -2.6 0 -2.6 -2.8 12/31/2006 23:30:00 14.9 2.4 20.2 8.4 13.7 2.9 21 8.4 14.3 2.4 20.2 8.4 346 3 346 165 -2.8 0 -2.6 -3 12/31/2006 23:40:00 14.6 1.7 19.5 10.7 13.1 2.5 19.5 7.2 13.8 1.9 18.7 9.1 346 0 346 165 -2.9 0 -2.6 -3 12/31/2006 23:50:00 15.7 2.2 21.4 9.1 14.4 2.8 21 8 15 2.3 21.4 9.5 346 0 346 165 -3 0 -2.8 -3.3 01/01/2007 00:00:00 15.6 2.2 20.6 10.3 14.3 2.3 20.6 8 14.8 2.3 21 9.5 346 0 346 165 -3 0 -2.8 -3.3 01/01/2007 00:10:00 15.8 2.6 21.4 8.4 14.8 2.7 23.7 8.4 15.4 2.7 21.4 9.5 346 0 346 165 -3 0 -2.8 -3.3 01/01/2007 00:20:00 14.9 2 19.9 10.3 13 2.4 19.5 8 14.7 2.1 21.4 9.9 346 0 346 165 -2.9 0 -2.8 -3 01/01/2007 00:30:00 10.9 1.8 16.8 6.5 10.6 1.9 17.2 5.3 10.8 1.8 17.2 6.8 346 0 346 165 -3 0.1 -2.6 -3 01/01/2007 00:40:00 12.1 1.8 17.9 8 11.2 1.7 16.4 6.8 12.1 1.7 18.3 8.8 346 0 346 165 -3 0 -2.8 -3.3 01/01/2007 00:50:00 11.6 1.7 16.8 7.2 11.2 1.7 16.8 6.5 11.4 1.6 17.2 7.6 346 0 346 165 -2.9 0 -2.8 -3 01/01/2007 01:00:00 13.3 2.6 21.4 7.6 13 2.5 21 7.6 13.1 2.7 21.4 6.8 346 0 346 165 -2.9 0 -2.6 -3 01/01/2007 01:10:00 14.3 2.5 21 8.4 14.1 2.3 19.5 8.4 13.9 2.4 20.2 8.8 346 0 346 165 -3 0.1 -2.6 -3.3 01/01/2007 01:20:00 12.8 2.1 18.7 7.6 12.5 2.1 17.6 8 12.8 1.9 16.8 7.2 346 0 346 165 -3.2 0 -2.8 -3.5 01/01/2007 01:30:00 14.9 3.2 22.9 7.2 14.4 3.1 22.1 6.8 14.7 3.1 23.7 6.5 346 0 346 165 -3.3 0 -3 -3.5 01/01/2007 01:40:00 19.4 3.6 28.7 9.9 18.8 3.5 27.9 9.1 19 3.6 27.9 9.1 340 10 346 165 -3.4 0 -3.3 -3.5 01/01/2007 01:50:00 20.2 3.5 30.6 12.6 19.4 3.1 28.3 13 19.7 3.5 28.7 12.6 332 12 332 165 -3.6 0.1 -3.3 -3.9 01/01/2007 02:00:00 20.6 3.3 31.3 12.6 19.6 3.2 30.2 12.2 20.2 3.3 30.6 11.8 337 10 326 165 -3.8 0 -3.5 -3.9 01/01/2007 02:10:00 21.2 2.6 29.4 14.9 20.5 2.5 28.7 14.9 20.7 2.7 32.4 14.9 337 9 340 165 -4 0.1 -3.7 -4.2 01/01/2007 02:20:00 21.9 3.1 28.3 14.1 20.8 3.3 28.7 13.3 21.4 3.2 28.7 13.3 341 8 337 165 -4.2 0 -3.9 -4.4 01/01/2007 02:30:00 21.1 2.7 26.8 14.5 20.5 3.1 26.8 12.6 20.6 2.5 28.3 14.1 339 8 340 165 -4.4 0 -4.2 -4.6 01/01/2007 02:40:00 20.2 2.5 27.5 14.9 19.5 2.7 27.5 12.2 20 2.6 26 14.9 339 9 338 165 -4.5 0 -4.4 -4.6 01/01/2007 02:50:00 18.7 2.5 25.2 13.3 17.9 2.6 24 10.7 18.5 2.6 26.8 11.5 338 11 354 165 -4.7 0 -4.4 -4.8 01/01/2007 03:00:00 17.2 2.4 23.7 11.8 16.4 2.2 22.6 11.5 16.8 2.3 22.1 11.8 339 10 353 165 -4.7 0 -4.6 -4.8 01/01/2007 03:10:00 15.3 2.7 24.8 10.7 14.4 2.1 21 9.5 15.1 2.6 25.2 9.5 338 13 353 165 -4.7 0 -4.6 -4.8 01/01/2007 03:20:00 18.3 3.6 28.3 10.3 18.3 3.8 29.1 10.7 17.6 4 28.7 10.3 326 12 338 165 -4.7 0 -4.4 -4.8 01/01/2007 03:30:00 17 2.7 25.6 9.9 16.9 2.6 25.6 9.5 16.6 2.5 24.8 9.5 330 10 332 165 -4.7 0 -4.4 -4.6 01/01/2007 03:40:00 16 2.7 22.9 10.3 15.8 2.8 23.3 9.9 15.7 2.7 23.3 9.9 330 13 333 165 -4.6 0 -4.4 -4.6 01/01/2007 03:50:00 16.5 2.8 24.4 9.1 16.2 2.8 24.8 8.8 15.5 3.1 24.8 8.4 320 21 336 165 -4.5 0 -4.4 -4.6 01/01/2007 04:00:00 16.2 3.1 22.9 9.1 15.6 2.7 21.8 9.5 15.4 3.1 22.6 9.1 333 15 355 165 -4.4 0 -4.2 -4.6 01/01/2007 04:10:00 16.1 2.5 21.4 9.1 16 2.4 22.1 9.5 14.9 2.4 21 8 313 20 338 165 -4.3 0 -3.9 -4.4 01/01/2007 04:20:00 16.2 2.5 24.4 10.3 16 2.5 24 10.7 14.8 2.4 22.6 9.1 310 18 263 165 -4.2 0 -3.9 -4.4 01/01/2007 04:30:00 14.4 2.2 22.1 8.8 14.3 2.1 22.9 9.1 13.3 2.4 20.6 6.1 311 17 302 165 -4.1 0 -3.9 -4.4 01/01/2007 04:40:00 13.6 1.7 20.2 9.1 13.4 1.6 19.5 9.5 12.8 1.7 18.7 9.1 322 15 323 165 -4.2 0 -3.9 -4.4 01/01/2007 04:50:00 15.3 2.3 22.9 9.9 15.1 2.1 22.6 9.9 14.9 2.2 21.8 10.7 327 15 355 165 -4.3 0 -4.2 -4.4 01/01/2007 05:00:00 15.7 3.1 23.7 7.6 15.2 2.9 23.3 6.8 15.4 3.1 22.9 9.5 332 14 348 165 -4.3 0 -4.2 -4.4 01/01/2007 05:10:00 15.7 3.2 24 8.8 15.4 2.9 24.8 7.2 15.1 3.3 25.2 7.2 325 17 345 165 -4.3 0 -4.2 -4.6 01/01/2007 05:20:00 13.6 2 19.5 9.1 13.4 1.9 19.1 8 13 1.9 19.1 7.6 323 16 338 165 -4.3 0 -4.2 -4.4 01/01/2007 05:30:00 13.2 1.8 18.7 9.1 13.2 1.8 18.3 9.5 12.2 1.6 16.4 7.2 317 15 301 165 -4.3 0 -4.2 -4.4 01/01/2007 05:40:00 14.5 1.8 20.6 9.1 14.3 2 20.2 7.6 12.8 1.7 16.4 8.4 309 15 307 165 -4.2 0.1 -3.9 -4.6 01/01/2007 05:50:00 15.9 2.2 22.1 9.9 15.7 2.1 21.8 9.5 13.9 2.1 19.5 9.1 304 11 310 165 -4.4 0 -4.2 -4.6 01/01/2007 06:00:00 17 2.2 22.9 10.7 16.8 2.1 23.3 10.7 14.6 2.1 22.6 9.9 302 11 289 165 -4.2 0 -3.9 -4.4 01/01/2007 06:10:00 16.8 2.1 25.6 11.5 16.8 2.1 25.6 11.5 14.2 2.4 24.4 8.4 301 10 292 165 -4.2 0.1 -3.9 -4.4 01/01/2007 06:20:00 17.6 1.8 24.4 13.3 17.5 1.8 23.7 13.3 14.2 2.2 22.1 9.1 301 8 309 165 -4.3 0 -3.9 -4.6 01/01/2007 06:30:00 17 2.1 23.7 11.8 17 2.1 23.3 11.8 14.2 2.6 21.8 8.4 301 12 303 165 -4.4 0.1 -3.9 -4.6 01/01/2007 06:40:00 16.7 1.7 22.1 11.8 16.7 1.7 21.8 11.8 13.8 2 19.5 8.8 301 9 313 165 -4.3 0 -3.9 -4.6 01/01/2007 06:50:00 15.8 1.7 20.2 11.5 15.7 1.7 19.9 11.5 12.9 1.8 18.3 8.8 300 9 282 165 -4.5 0 -4.4 -4.6 01/01/2007 07:00:00 16.6 2.4 22.1 8 16.6 2.4 21.8 8 13.5 2.4 22.1 8.8 298 11 304 165 -4.3 0.1 -3.9 -4.6 01/01/2007 07:10:00 16.8 1.8 22.1 11.5 16.8 1.8 21.8 11.1 13.3 2 19.9 7.2 295 8 265 165 -4.4 0 -4.2 -4.6 01/01/2007 07:20:00 15.1 1.7 20.6 9.9 15.1 1.8 19.9 9.9 12.2 1.9 19.5 8.4 297 9 300 165 -4.5 0 -4.2 -4.6 01/01/2007 07:30:00 16.2 1.9 21.4 10.7 16.2 2 21.8 11.1 12.6 2.2 19.9 7.6 297 8 301 165 -4.5 0 -4.4 -4.6 01/01/2007 07:40:00 16.2 2.1 20.2 9.9 16.2 2.1 20.2 9.9 12.7 1.8 17.9 7.2 299 8 296 165 -4.6 0.1 -4.4 -4.6 01/01/2007 07:50:00 15.8 2.2 22.6 9.9 15.9 2.2 22.6 10.3 13.1 2.4 22.1 7.2 292 9 280 165 -4.5 0 -4.2 -4.6 01/01/2007 08:00:00 15.8 1.7 20.2 11.1 15.8 1.7 20.6 11.1 13 2.3 18.3 8.4 291 9 291 165 -4.2 0.1 -3.7 -4.6 01/01/2007 08:10:00 16 2 20.6 10.3 16 2.1 20.6 10.3 13.1 2.5 19.1 8 291 8 308 165 -4.2 0 -3.9 -4.4 01/01/2007 08:20:00 17.3 1.8 22.9 11.8 17.4 1.8 22.9 12.2 14.6 2.4 22.1 9.5 290 7 293 165 -4.3 0 -4.2 -4.6 01/01/2007 08:30:00 16.5 1.9 21.8 11.1 16.6 2 22.1 10.7 13 2.6 22.6 8.4 294 9 291 165 -4.2 0.1 -3.7 -4.6 01/01/2007 08:40:00 16.6 2 21.4 11.1 16.7 1.9 20.6 11.5 12.9 2.3 19.9 7.6 294 8 301 165 -4.1 0.1 -3.5 -4.4 01/01/2007 08:50:00 16.1 2.3 22.6 9.5 16.1 2.3 22.1 9.1 12.5 2.2 17.9 8 296 8 298 165 -4 0.1 -3.5 -4.4 01/01/2007 09:00:00 16.1 1.9 20.6 11.1 16 1.9 21 11.5 12.6 2.1 18.3 8 300 9 286 165 -3.9 0 -3.7 -4.4 01/01/2007 09:10:00 14 1.3 17.6 10.3 13.9 1.3 17.6 9.9 11 1.3 14.5 7.6 299 9 301 165 -4.1 0 -3.9 -4.2 01/01/2007 09:20:00 11.6 1.6 15.6 8 11.5 1.6 16.1 6.8 9.6 1.6 14.1 5.7 293 9 290 165 -4.1 0.1 -3.9 -4.4 01/01/2007 09:30:00 9.8 1.7 14.5 5.3 9.8 1.7 14.1 5.7 8 1.5 13 4.9 294 11 302 165 -4.3 0 -3.9 -4.6 01/01/2007 09:40:00 10.7 1.3 14.1 7.6 10.5 1.3 14.1 6.8 9.2 1.7 13.7 4.9 300 12 292 165 -4.3 0 -4.2 -4.4 01/01/2007 09:50:00 14.6 1.2 17.6 10.7 14.5 1.2 17.6 10.7 12.9 1.7 16.4 8.4 307 6 310 165 -4.1 0 -3.9 -4.4 01/01/2007 10:00:00 14.3 1.1 16.8 10.7 14.2 1.1 16.8 10.7 12.5 1.6 16.8 9.1 306 7 306 165 -3.9 0 -3.7 -4.2 01/01/2007 10:10:00 14.2 1.2 17.2 11.1 14 1.2 17.2 11.5 12.4 1.6 16.4 8 308 6 308 165 -3.8 0 -3.5 -3.9 01/01/2007 10:20:00 13.6 1.4 17.9 10.3 13.5 1.4 17.6 9.9 11.5 1.5 16.1 7.6 305 6 310 165 -3.7 0.1 -3.5 -3.9 01/01/2007 10:30:00 13.6 1.3 16.4 10.3 13.4 1.3 16.4 10.3 10.3 1.2 13.7 6.5 300 7 300 165 -3.6 0 -3.3 -3.7 01/01/2007 10:40:00 14.3 1.2 16.8 11.1 14.2 1.2 16.4 11.1 11.4 1.2 14.9 8.4 303 6 305 165 -3.5 0 -3.3 -3.5 01/01/2007 10:50:00 15.3 1.2 18.3 12.2 15.2 1.2 17.9 11.5 12.5 1.3 15.3 9.1 303 5 297 165 -3.4 0 -3.3 -3.5 01/01/2007 11:00:00 16.4 1.2 18.3 13.3 16.2 1.2 18.3 13.3 12.9 1.4 16.4 9.5 303 6 306 165 -3.2 0.1 -2.8 -3.5 01/01/2007 11:10:00 15.3 1.5 18.3 9.9 15.1 1.5 17.9 9.9 12.1 1.3 16.4 8.4 302 8 293 165 -3 0 -2.8 -3.3 01/01/2007 11:20:00 14.9 1.3 17.9 10.3 14.7 1.3 17.9 10.3 12.1 1.3 16.8 8.8 302 6 302 165 -3 0 -2.8 -3.3 01/01/2007 11:30:00 15.6 1.2 17.9 12.2 15.5 1.2 17.9 11.8 12.6 1.3 16.8 9.9 304 6 304 165 -3 0 -2.8 -3 01/01/2007 11:40:00 16.2 1.3 19.1 13 16.1 1.3 18.7 12.2 13.3 1.3 16.8 9.9 303 6 297 165 -2.9 0 -2.6 -3 01/01/2007 11:50:00 15.4 1.2 17.6 11.8 15.2 1.2 17.9 11.8 12.4 1.5 16.4 8.8 303 7 304 165 -2.6 0.1 -2.1 -2.8 01/01/2007 12:00:00 15.8 1.2 19.5 13 15.6 1.2 19.5 13 12.1 1.3 17.2 8.8 302 6 306 165 -2.4 0 -2.1 -2.6 01/01/2007 12:10:00 15 1.3 18.3 11.1 14.9 1.3 18.7 11.1 12 1.5 18.7 8.4 304 6 288 165 -2.5 0 -2.4 -2.6 01/01/2007 12:20:00 13.9 1.4 16.8 9.5 13.7 1.4 16.8 9.5 11 1.3 14.1 8 302 7 304 165 -2.4 0 -2.1 -2.6 01/01/2007 12:30:00 14 1.3 16.8 10.3 13.8 1.3 16.8 10.7 10.6 1.3 14.9 8 299 7 298 165 -2.4 0 -2.1 -2.6 01/01/2007 12:40:00 13.6 1.5 17.6 8.8 13.5 1.5 17.6 8 10.5 1.5 15.3 6.8 297 9 297 165 -2.5 0 -2.1 -2.6 01/01/2007 12:50:00 14.1 1.1 16.8 10.3 13.9 1.2 16.4 9.9 10.4 1.2 14.5 7.2 300 7 307 165 -2.5 0 -2.4 -2.8 01/01/2007 13:00:00 12.1 1.3 14.9 8.4 12 1.3 14.9 8.4 9.4 1.4 14.1 6.1 295 7 302 165 -2.5 0 -2.6 -2.8 01/01/2007 13:10:00 12 1.5 15.6 8.4 11.8 1.5 15.3 8.4 9 1.2 12.6 6.5 300 8 301 165 -2.5 0 -2.4 -2.6 01/01/2007 13:20:00 11.2 1.3 14.1 8 11 1.3 13.7 8 8.4 1.1 11.5 5.7 298 8 297 165 -2.6 0 -2.6 -2.8 01/01/2007 13:30:00 11 1.1 13.7 7.6 10.9 1 13.7 8.4 8.4 1 11.1 5.7 298 7 295 165 -2.7 0 -2.6 -2.8 01/01/2007 13:40:00 11.9 1.1 13.7 8 11.8 1.1 13.7 8.4 8.8 1.1 13 6.5 298 7 302 165 -2.8 0 -2.6 -3 01/01/2007 13:50:00 11.6 1.3 15.3 8.4 11.5 1.4 15.6 8.4 9 1.3 13.7 6.5 302 7 291 165 -2.8 0 -2.6 -3 01/01/2007 14:00:00 11.8 1.2 14.5 8.8 11.6 1.2 14.1 8.8 9.3 1.2 13 6.5 303 8 304 165 -2.7 0 -2.6 -2.8 01/01/2007 14:10:00 11.4 1.3 14.9 8.4 11.2 1.2 14.5 8.4 9.8 1.5 13.7 6.5 307 7 304 165 -2.8 0 -2.6 -3 01/01/2007 14:20:00 10.6 1.2 13.3 7.6 10.4 1.2 13 7.6 8.7 1.3 12.6 5.3 304 8 307 165 -2.7 0 -2.6 -2.8 01/01/2007 14:30:00 10.6 1.2 14.1 7.2 10.4 1.2 14.1 6.8 9.3 1.5 12.2 6.1 308 5 301 165 -2.7 0 -2.6 -2.8 01/01/2007 14:40:00 9.4 1 11.5 6.8 9.2 1 11.1 6.5 7.4 0.8 10.3 4.9 302 6 307 165 -2.9 0.1 -2.6 -3.3 01/01/2007 14:50:00 9.5 1 11.1 6.8 9.3 0.9 11.1 6.5 7.2 0.9 9.9 4.6 297 7 295 165 -3.2 0 -3 -3.5 01/01/2007 15:00:00 10.3 1.1 12.6 7.2 10.1 1 12.2 7.2 7.9 1 10.3 5.3 299 7 304 165 -3.4 0 -3.3 -3.5 01/01/2007 15:10:00 8.8 1 11.5 5.7 8.6 1 11.1 5.3 7 1 9.9 4.6 298 9 296 165 -3.4 0 -3.3 -3.5 01/01/2007 15:20:00 7.8 1 10.3 4.6 7.7 1 9.9 4.6 6.2 1.1 9.5 3.4 299 9 311 165 -3.3 0 -3 -3.5 01/01/2007 15:30:00 6.5 1.1 9.5 4.6 6.4 1.1 9.5 4.2 5.3 1.1 8.4 3 301 11 292 165 -3.4 0 -3 -3.5 01/01/2007 15:40:00 7.2 0.9 9.9 4.9 7.1 0.9 9.9 4.9 5.8 1 9.1 3.8 303 8 310 165 -3.4 0 -3.3 -3.5 01/01/2007 15:50:00 6.9 1.1 10.3 4.6 6.8 1.1 9.9 4.9 5.5 1 8.4 3 304 8 301 165 -3.4 0 -3.3 -3.5 01/01/2007 16:00:00 6.6 0.9 8.8 4.2 6.5 0.8 8.8 3.8 5.4 1 8.4 3.8 294 8 293 165 -3 0.1 -2.8 -3.5 01/01/2007 16:10:00 6.3 0.8 9.1 4.6 6.3 0.7 9.1 4.9 5.7 1 8.4 3.4 289 8 295 165 -3.4 0.1 -2.8 -3.5 01/01/2007 16:20:00 5.7 0.7 8 4.2 5.7 0.7 7.6 3.8 5 0.8 7.2 2.6 295 10 306 165 -3.4 0 -3.3 -3.5 01/01/2007 16:30:00 6.3 1 8.8 3.8 6.3 1 8.8 3.8 6 1.1 8.8 3.4 286 10 305 165 -3.4 0.1 -3.3 -3.5 01/01/2007 16:40:00 3.6 1.4 8 0.7 3.5 1.5 7.6 0.4 3.4 1.3 8 1.1 296 19 293 165 -3.5 0.1 -3.3 -3.5 01/01/2007 16:50:00 3.8 2 8.4 0.4 3.7 2 8 0.4 3.1 1.5 6.8 0.4 303 13 301 165 -3.8 0 -3.5 -4.2 01/01/2007 17:00:00 6.4 0.9 8.8 4.6 6.3 0.8 8.4 4.2 5.3 0.9 7.6 2.6 296 9 282 165 -3.8 0 -3.5 -3.9 01/01/2007 17:10:00 7.4 0.8 9.5 4.9 7.2 0.8 9.1 4.9 6 0.8 8.8 3.8 296 8 297 165 -3.8 0 -3.5 -3.9 01/01/2007 17:20:00 5.9 1 8 3 5.9 0.9 8 3 4.4 1 6.5 1.9 298 10 296 165 -4.2 0.1 -3.7 -4.6 01/01/2007 17:30:00 6.3 0.9 8.4 4.2 6.3 0.9 8.4 4.2 5.1 0.8 7.2 2.6 292 8 299 165 -3.8 0 -3.5 -4.2 01/01/2007 17:40:00 3.9 0.7 5.7 1.9 4 0.7 5.7 1.9 3.7 0.6 5.7 1.9 277 9 272 165 -4.2 0.1 -3.7 -4.4 01/01/2007 17:50:00 4.3 0.7 5.7 2.3 4.4 0.7 5.7 2.3 4.1 0.6 5.3 2.3 279 7 285 165 -4.3 0 -4.2 -4.6 01/01/2007 18:00:00 5.4 0.7 7.2 3.4 5.4 0.7 6.8 3.8 5.2 0.8 6.8 3 284 7 291 165 -4.2 0 -3.9 -4.4 01/01/2007 18:10:00 6.3 0.9 8.8 4.2 6.3 0.9 8.8 3.8 5.8 1 8.8 3.8 288 5 290 165 -4.2 0 -3.9 -4.4 01/01/2007 18:20:00 6.9 0.6 8.4 5.3 6.9 0.6 8.4 5.3 5.9 0.9 8.4 3.8 293 5 290 165 -4 0 -3.9 -4.2 01/01/2007 18:30:00 6.8 0.5 8.4 5.3 6.8 0.5 8.4 5.3 5.6 0.8 8 3.4 291 3 291 165 -4.3 0 -3.9 -4.4 01/01/2007 18:40:00 6 0.6 7.6 4.9 6 0.6 7.6 4.9 4.4 0.6 6.5 3 295 4 298 165 -4.2 0 -3.9 -4.4 01/01/2007 18:50:00 7.1 0.5 8 5.7 7.1 0.5 8 5.7 5.5 0.6 7.2 3.8 294 5 292 165 -4.2 0.1 -3.9 -4.6 01/01/2007 19:00:00 6.9 0.5 8 5.3 6.9 0.5 8.4 5.3 6.1 0.6 8 4.2 290 4 289 165 -4.2 0 -4.2 -4.4 01/01/2007 19:10:00 6 0.5 7.2 4.9 6 0.5 7.2 4.9 5.2 0.6 6.8 3.4 288 4 290 165 -4.2 0 -3.9 -4.4 01/01/2007 19:20:00 5.1 0.6 6.5 3.8 5.1 0.6 6.8 3.8 4.1 0.6 5.7 2.6 294 4 298 165 -4.2 0 -3.9 -4.4 01/01/2007 19:30:00 4.4 0.4 5.7 3 4.4 0.5 5.7 3 3.6 0.6 5.3 2.3 295 6 289 165 -4.2 0 -3.9 -4.4 01/01/2007 19:40:00 3.4 0.5 4.6 2.3 3.3 0.5 4.6 2.3 3.1 0.5 4.6 1.9 308 5 302 165 -4.2 0 -3.9 -4.4 01/01/2007 19:50:00 2.6 0.5 3.8 1.5 2.5 0.5 3.8 1.5 2.6 0.4 3.8 1.5 310 6 311 165 -4.1 0 -3.9 -4.4 01/01/2007 20:00:00 2.8 0.4 3.8 1.9 2.8 0.4 3.8 1.9 2.8 0.4 3.8 1.9 311 8 295 165 -4.2 0.1 -3.9 -4.4 01/01/2007 20:10:00 2.3 0.3 3 1.5 2.4 0.3 3 1.5 2.4 0.3 3 1.5 309 5 310 165 -4.2 0 -3.9 -4.4 01/01/2007 20:20:00 2.5 0.4 3.4 1.5 2.6 0.3 3.4 1.9 2.3 0.4 3 1.1 308 7 310 165 -3.9 0 -3.7 -4.2 01/01/2007 20:30:00 2.1 0.4 3 1.1 2.2 0.3 3.4 1.5 2 0.3 3 1.1 307 6 300 165 -3.8 0 -3.5 -3.9 01/01/2007 20:40:00 3 0.8 4.6 1.5 3.1 0.8 4.6 1.9 2.9 0.5 3.8 1.9 311 7 298 165 -4 0 -3.9 -4.2 01/01/2007 20:50:00 3.5 0.4 4.6 2.3 3.6 0.4 4.6 2.3 2.9 0.4 4.2 1.9 296 4 296 165 -4 0 -3.9 -4.2 01/01/2007 21:00:00 2.7 0.6 3.8 1.5 2.7 0.5 3.8 1.5 2.5 0.5 4.2 1.5 286 11 289 165 -3.9 0 -3.5 -4.2 01/01/2007 21:10:00 2.6 0.4 3.4 1.5 2.6 0.4 3.4 1.5 2.5 0.5 3.4 1.5 284 6 277 165 -3.7 0.1 -3.5 -3.9 01/01/2007 21:20:00 2.2 0.4 3 1.1 2.2 0.4 3.4 1.1 2.1 0.5 3.4 0.7 281 8 282 165 -3.6 0 -3.3 -3.7 01/01/2007 21:30:00 1.8 0.3 2.3 0.7 1.7 0.3 2.3 0.7 1.5 0.3 2.3 0.7 290 8 288 165 -3.6 0 -3.5 -3.9 01/01/2007 21:40:00 2.2 0.3 3 1.5 2.1 0.3 3 1.5 2.2 0.4 3 0.7 313 6 318 165 -3.7 0 -3.3 -3.9 01/01/2007 21:50:00 1.4 0.3 2.3 0.7 1.3 0.4 2.3 0.4 1.7 0.2 2.3 1.1 318 7 305 165 -3.7 0 -3.5 -3.9 01/01/2007 22:00:00 2 0.4 2.6 0.7 1.9 0.5 2.6 0.4 1.9 0.4 2.6 1.1 305 4 306 165 -3.8 0 -3.5 -3.9 01/01/2007 22:10:00 1.9 0.4 2.6 1.1 1.9 0.4 2.6 1.1 1.8 0.3 2.6 1.1 289 11 304 165 -3.6 0 -3.3 -3.9 01/01/2007 22:20:00 1.4 0.4 2.3 0.4 1.4 0.4 2.3 0.4 1.7 0.4 2.6 0.7 288 16 310 165 -3.4 0.1 -3.3 -3.5 01/01/2007 22:30:00 1.3 0.4 1.9 0.4 1.1 0.4 1.9 0.4 1.4 0.3 2.3 0.4 300 9 312 165 -3.7 0.1 -3.5 -3.9 01/01/2007 22:40:00 0.7 0.4 1.5 0.4 0.5 0.3 1.5 0.4 1.4 0.3 1.9 0.4 274 10 284 165 -3.4 0 -3 -3.5 01/01/2007 22:50:00 1.1 0.4 2.3 0.4 0.9 0.5 2.3 0.4 1.5 0.3 2.3 0.7 279 8 286 165 -3.2 0 -2.8 -3.3 01/01/2007 23:00:00 0.9 0.4 1.9 0.4 0.9 0.4 1.9 0.4 1.6 0.3 2.3 0.7 284 4 284 165 -3.2 0 -3 -3.5 01/01/2007 23:10:00 0.6 0.4 1.9 0.4 0.5 0.4 1.9 0.4 1.2 0.3 1.9 0.7 262 14 290 165 -3 0 -2.8 -3.3 01/01/2007 23:20:00 1.4 0.5 2.3 0.4 1.5 0.5 2.6 0.4 1.8 0.3 2.6 1.1 285 7 281 165 -3.2 0 -3 -3.5 01/01/2007 23:30:00 1.4 0.4 2.3 0.4 1.5 0.4 2.3 0.4 1.4 0.3 2.3 0.7 290 6 292 165 -3.5 0 -3 -3.5 01/01/2007 23:40:00 1.4 0.3 2.3 0.4 1.5 0.3 2.3 0.4 1.6 0.3 2.3 0.7 288 5 286 165 -3.6 0 -3.3 -3.5 01/01/2007 23:50:00 1.6 0.3 2.6 1.1 1.7 0.3 2.6 1.1 1.6 0.4 2.3 0.7 302 3 303 165 -3.4 0 -3.3 -3.5 01/02/2007 00:00:00 1.2 0.6 2.6 0.4 1.3 0.6 2.6 0.4 1.4 0.5 2.3 0.4 298 8 300 165 -3.4 0 -3.3 -3.5 01/02/2007 00:10:00 1.7 0.3 2.3 0.7 1.8 0.3 2.3 0.7 1.5 0.3 2.3 0.7 294 1 296 165 -3.1 0 -2.8 -3.3 01/02/2007 00:20:00 2.6 0.5 3.8 1.5 2.7 0.5 3.8 1.5 2.7 0.5 3.8 1.5 287 5 282 165 -3.2 0 -3 -3.5 01/02/2007 00:30:00 3.4 0.4 4.2 2.3 3.5 0.4 4.6 2.6 3.2 0.5 4.2 1.9 286 4 287 165 -3.4 0 -3.3 -3.5 01/02/2007 00:40:00 3.9 0.2 4.6 3.4 3.9 0.2 4.6 3.4 3.5 0.4 4.2 2.3 288 5 291 165 -3.6 0 -3.3 -3.9 01/02/2007 00:50:00 3.6 0.3 4.2 2.3 3.7 0.3 4.6 3 3.6 0.4 4.9 2.6 277 4 273 165 -3.5 0 -3.3 -3.7 01/02/2007 01:00:00 4.1 0.5 5.3 3 4.1 0.5 5.3 3 3.8 0.5 4.9 2.6 286 4 282 165 -4 0.1 -3.5 -4.4 01/02/2007 01:10:00 5.1 0.5 6.5 3.8 5.1 0.5 6.5 4.2 3.9 0.6 5.3 2.6 299 6 302 165 -4 0.1 -3.7 -4.4 01/02/2007 01:20:00 4.9 0.5 6.5 3.4 4.9 0.5 6.1 3.8 4.4 0.5 6.1 3 309 4 307 165 -4.1 0 -3.5 -4.4 01/02/2007 01:30:00 4.2 0.6 6.5 3 4.2 0.6 6.5 3 3.7 0.5 5.3 2.3 308 8 307 165 -3.7 0 -3.5 -3.9 01/02/2007 01:40:00 5 0.6 6.8 3.8 5 0.6 6.8 3.8 4 0.7 6.5 2.3 296 7 297 165 -3.8 0 -3.5 -4.2 01/02/2007 01:50:00 4.9 0.8 7.2 2.6 4.9 0.8 6.8 2.6 4.1 0.8 6.5 2.3 292 12 298 165 -4 0 -3.9 -4.4 01/02/2007 02:00:00 6.3 0.6 8 4.9 6.3 0.6 8 4.9 5.1 0.8 7.6 3 299 8 306 165 -3.8 0.1 -3.5 -4.2 01/02/2007 02:10:00 5.3 0.8 7.2 3.8 5.2 0.8 7.2 3.4 4.4 0.7 6.8 3 305 10 294 165 -3.9 0.3 -3.5 -4.4 01/02/2007 02:20:00 3.8 0.8 6.1 1.9 3.7 0.8 5.7 1.5 3.6 0.9 5.7 1.5 316 15 315 165 -4.3 0.1 -3.9 -4.6 01/02/2007 02:30:00 2.9 0.7 5.3 1.5 2.8 0.7 4.9 1.5 2.9 0.5 4.2 1.9 335 11 323 165 -4.8 0.1 -4.4 -5 01/02/2007 02:40:00 3 0.7 4.9 0.7 2.8 0.7 4.9 1.1 3 0.7 4.6 1.1 329 17 329 165 -4.8 0.2 -4.4 -5.3 01/02/2007 02:50:00 3 0.6 4.9 1.5 3 0.6 4.9 0.7 2.6 0.5 4.2 1.1 307 14 307 165 -4.2 0 -3.9 -4.6 01/02/2007 03:00:00 2.7 1 5.3 0.7 2.8 1 5.3 1.1 2.4 0.8 4.9 0.7 301 12 303 165 -4.2 0.1 -3.9 -4.6 01/02/2007 03:10:00 3.3 0.8 5.3 1.5 3.2 0.8 5.3 1.5 2.6 0.6 4.9 1.5 301 9 294 165 -4 0.2 -3.5 -4.6 01/02/2007 03:20:00 2.6 0.6 4.6 1.1 2.6 0.6 4.6 1.1 2.3 0.6 3.8 0.7 286 9 292 165 -4.5 0 -4.4 -4.6 01/02/2007 03:30:00 1.3 0.5 3 0.4 1 0.6 3 0.4 1.1 0.5 2.3 0.4 328 20 292 165 -4.9 0 -4.6 -5.3 01/02/2007 03:40:00 0.9 0.6 2.6 0.4 1 0.6 2.6 0.4 1.2 0.4 2.3 0.4 289 16 304 165 -4.5 0.3 -3.9 -5 01/02/2007 03:50:00 2.2 0.7 3.8 0.4 2.2 0.6 3.8 0.7 2.1 0.5 3.8 0.7 311 18 359 165 -4.2 0.1 -3.9 -4.4 01/02/2007 04:00:00 2.7 0.7 4.2 0.7 2.7 0.6 4.6 0.7 2.5 0.6 4.9 1.1 316 16 343 165 -4.5 0 -4.4 -4.8 01/02/2007 04:10:00 0.9 0.8 3 0.4 0.9 0.8 3 0.4 0.9 0.7 2.6 0.4 304 7 310 165 -4.3 0.1 -3.9 -4.6 01/02/2007 04:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0.1 1.1 0.4 287 27 165 165 -4.4 0 -4.2 -4.6 01/02/2007 04:30:00 1.1 0.6 2.3 0.4 1.1 0.6 2.3 0.4 1.2 0.6 2.3 0.4 303 32 319 165 -4.4 0 -4.2 -4.6 01/02/2007 04:40:00 1.6 0.7 3 0.4 1.7 0.7 3 0.4 1.4 0.6 2.6 0.4 302 10 302 165 -4.5 0 -4.2 -4.6 01/02/2007 04:50:00 2.4 0.4 3.4 1.5 2.4 0.4 3.4 1.5 2 0.4 3 0.7 298 5 290 165 -4.4 0 -4.4 -4.6 01/02/2007 05:00:00 3.6 0.6 4.6 1.9 3.7 0.6 4.6 1.9 3.4 0.6 4.9 1.9 286 4 283 165 -4.4 0 -4.4 -4.6 01/02/2007 05:10:00 4.7 0.8 6.1 2.6 4.7 0.8 6.1 2.3 3.7 0.7 5.3 1.9 301 6 302 165 -4.7 0.1 -4.4 -5 01/02/2007 05:20:00 4.9 0.5 6.5 3.8 4.9 0.5 6.8 3.8 4.3 0.7 6.5 2.6 306 8 302 165 -4.8 0 -4.4 -5 01/02/2007 05:30:00 4.6 0.4 5.7 3.8 4.5 0.4 5.7 3.4 4.6 0.3 5.3 3.8 321 6 303 165 -5.5 0.2 -5 -5.9 01/02/2007 05:40:00 4 0.6 4.9 3 3.8 0.8 4.9 1.5 4.1 0.5 4.9 3 336 13 317 165 -5.7 0 -5.5 -5.9 01/02/2007 05:50:00 4.3 0.5 5.7 2.6 4.2 0.6 5.7 2.3 4.4 0.4 5.7 3 328 10 317 165 -5.6 0 -5.5 -5.7 01/02/2007 06:00:00 4.4 0.4 5.3 3.4 4.3 0.5 5.3 2.6 4.4 0.4 5.3 3.4 338 7 333 165 -5.4 0 -5.3 -5.7 01/02/2007 06:10:00 4.2 0.4 4.9 3 4.2 0.4 5.3 3 4.3 0.4 5.3 2.6 337 9 315 165 -5.5 0 -5.3 -5.7 01/02/2007 06:20:00 3.9 0.5 5.3 2.6 3.8 0.5 5.7 2.3 4 0.4 5.3 2.6 332 11 326 165 -5.5 0.1 -5.3 -5.7 01/02/2007 06:30:00 3.7 0.5 5.3 2.3 3.6 0.5 5.3 2.3 3.6 0.4 4.9 2.6 321 10 324 165 -5.3 0 -5 -5.5 01/02/2007 06:40:00 2.4 0.5 3.4 1.5 2.3 0.5 3.4 1.1 2.3 0.6 3.4 0.7 323 17 339 165 -5.4 0 -5.3 -5.7 01/02/2007 06:50:00 2.5 0.5 4.2 1.5 2.5 0.5 4.2 1.5 2 0.5 3.4 0.7 288 7 296 165 -5.3 0 -5.3 -5.5 01/02/2007 07:00:00 3.1 0.7 4.6 1.5 3.1 0.7 4.6 1.5 2.7 0.6 4.6 1.5 291 7 295 165 -5 0.1 -4.6 -5.5 01/02/2007 07:10:00 2.4 0.7 4.2 1.1 2.4 0.7 4.2 1.1 2 0.5 3.4 1.1 292 8 295 165 -4.9 0 -4.6 -5.3 01/02/2007 07:20:00 1.4 0.4 2.3 0.4 1.3 0.4 2.6 0.4 1.4 0.3 2.3 0.7 299 9 293 165 -5 0 -4.6 -5 01/02/2007 07:30:00 1.6 0.6 3.8 0.4 1.6 0.5 3.4 0.4 1.7 0.4 3 0.7 318 11 320 165 -5 0 -4.6 -5.3 01/02/2007 07:40:00 2.4 0.8 3.8 0.4 2.4 0.7 3.8 0.4 2.4 0.6 3.8 0.7 320 12 302 165 -5.1 0.1 -4.6 -5.3 01/02/2007 07:50:00 1.2 0.7 3 0.4 1.2 0.7 3 0.4 1.5 0.7 2.6 0.4 339 9 325 165 -5.2 0.1 -4.8 -5.3 01/02/2007 08:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.7 0.4 330 0 165 165 -5.3 0 -5 -5.5 01/02/2007 08:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0.1 0.7 0.4 254 28 165 165 -5.2 0 -4.8 -5.5 01/02/2007 08:20:00 0.4 0 0.4 0.4 0.4 0.1 0.7 0.4 0.4 0.2 1.1 0.4 310 69 165 165 -5 0 -4.8 -5.3 01/02/2007 08:30:00 0.6 0.3 1.5 0.4 0.5 0.3 1.5 0.4 1.2 0.4 2.3 0.4 348 6 357 165 -5.1 0.1 -5 -5.3 01/02/2007 08:40:00 1.6 0.5 3 0.7 1.5 0.5 3 0.4 1.8 0.4 2.6 1.1 343 11 1 165 -5.3 0 -5 -5.5 01/02/2007 08:50:00 1.7 0.4 2.6 0.7 1.1 0.5 2.3 0.4 2.1 0.3 3 1.5 357 7 7 165 -5.4 0 -5.3 -5.7 01/02/2007 09:00:00 2 0.4 3 1.1 1.3 0.5 3 0.4 2.4 0.3 3 1.5 357 6 349 165 -5.5 0 -5.3 -5.7 01/02/2007 09:10:00 2.3 0.3 3 1.5 1.2 0.6 3 0.4 2.7 0.3 3.4 2.3 357 5 355 165 -5.5 0 -5.3 -5.7 01/02/2007 09:20:00 2.8 0.2 3.4 2.3 1.7 0.6 3.4 0.7 3.1 0.2 3.4 2.6 357 5 357 165 -5.5 0 -5.3 -5.7 01/02/2007 09:30:00 3.2 0.5 4.6 2.3 2.3 1 4.9 0.7 3.3 0.4 4.6 2.3 353 6 343 165 -5.6 0 -5.5 -5.7 01/02/2007 09:40:00 3.5 0.6 4.9 2.3 3.3 0.7 4.9 1.1 3.5 0.5 4.9 2.3 341 9 343 165 -5.5 0 -5.5 -5.7 01/02/2007 09:50:00 4.8 0.6 6.1 3 4.7 0.7 6.1 1.9 4.6 0.7 6.1 3 344 5 343 165 -5.6 0 -5.5 -5.7 01/02/2007 10:00:00 3.9 0.4 4.9 3 3.4 0.7 5.3 1.5 3.9 0.3 4.9 3 348 5 339 165 -5.7 0 -5.5 -5.7 01/02/2007 10:10:00 3.9 0.7 5.3 2.6 3.5 0.9 5.7 1.5 3.9 0.6 5.3 2.6 348 8 349 165 -5.6 0 -5.5 -5.7 01/02/2007 10:20:00 4.7 0.5 6.1 3.4 4.6 0.6 6.1 2.3 4.6 0.6 6.1 3.4 341 7 338 165 -5.6 0 -5.5 -5.7 01/02/2007 10:30:00 5.1 0.6 6.5 3.4 5 0.7 6.8 2.6 5 0.6 6.5 3.4 342 6 341 165 -5.5 0 -5.5 -5.7 01/02/2007 10:40:00 5.2 0.8 7.2 3.4 5.1 1 7.2 2.3 5.3 0.8 7.2 3.8 343 6 339 165 -5.5 0 -5.5 -5.7 01/02/2007 10:50:00 5.5 0.6 6.8 3.8 5.5 0.8 6.8 2.6 5.5 0.7 6.8 3.4 342 5 336 165 -5.5 0 -5.3 -5.7 01/02/2007 11:00:00 6 0.5 7.2 4.9 6 0.6 7.2 3.8 6 0.5 7.2 4.9 345 3 344 165 -5.4 0 -5.3 -5.7 01/02/2007 11:10:00 6 0.6 7.2 4.6 6 0.6 7.6 4.2 6.1 0.5 7.6 4.9 343 4 344 165 -5.4 0 -5.3 -5.5 01/02/2007 11:20:00 6.2 0.5 7.2 4.6 6.2 0.6 7.2 3.4 6.2 0.5 7.2 4.9 343 3 340 165 -5.3 0 -5 -5.5 01/02/2007 11:30:00 6.2 0.4 7.2 4.9 6.1 0.8 7.6 3 6.3 0.4 7.2 5.3 345 4 339 165 -5.3 0 -5 -5.5 01/02/2007 11:40:00 6.5 0.4 7.6 5.3 6.4 0.6 7.6 4.6 6.6 0.4 7.6 5.3 345 3 341 165 -5.3 0 -5.3 -5.5 01/02/2007 11:50:00 5.8 0.5 6.8 4.2 4.6 1 7.6 1.9 5.9 0.4 6.8 4.9 351 4 348 165 -5.3 0 -5 -5.5 01/02/2007 12:00:00 3.4 0.6 4.9 2.6 2 0.6 3.8 0.7 3.7 0.6 4.9 2.6 356 5 351 165 -5.2 0 -5 -5.3 01/02/2007 12:10:00 5.6 0.8 6.8 3.8 5.1 1.5 7.6 1.5 5.7 0.7 7.2 4.2 346 6 341 165 -5.3 0 -5 -5.5 01/02/2007 12:20:00 5.7 0.5 6.8 4.2 5.7 0.6 6.8 3.4 5.8 0.5 6.8 4.2 341 5 337 165 -5.3 0 -5 -5.5 01/02/2007 12:30:00 6.3 0.5 7.2 4.9 6.3 0.5 7.6 4.9 6.3 0.5 7.6 4.9 344 3 344 165 -5.2 0 -5 -5.3 01/02/2007 12:40:00 6.2 0.5 7.6 5.3 6.3 0.5 8 4.6 6.3 0.5 7.6 4.9 344 3 347 165 -5.2 0 -5 -5.3 01/02/2007 12:50:00 7 0.4 8 5.7 7 0.5 8.4 5.3 7 0.5 8.4 5.7 342 4 344 165 -5 0 -4.8 -5.3 01/02/2007 13:00:00 7.2 0.5 8.8 5.7 7.3 0.7 8.8 4.2 7.3 0.5 8.8 5.7 343 4 343 165 -4.9 0 -4.6 -5 01/02/2007 13:10:00 7.3 0.5 8.4 5.3 7.3 0.6 9.1 5.3 7.3 0.6 8.8 5.3 345 3 348 165 -4.9 0 -4.6 -5 01/02/2007 13:20:00 7.4 0.5 8.8 5.7 7.4 0.7 8.8 4.2 7.4 0.5 8.4 5.7 342 4 339 165 -5.1 0 -4.8 -5.3 01/02/2007 13:30:00 8.1 0.6 9.9 6.8 8.2 0.7 10.7 6.5 8.1 0.6 9.9 6.5 341 4 340 165 -5.2 0 -5 -5.3 01/02/2007 13:40:00 7.8 0.7 9.1 6.1 7.8 0.8 9.5 6.1 7.9 0.6 9.5 6.1 344 5 351 165 -5 0 -4.8 -5.3 01/02/2007 13:50:00 8.3 0.6 9.9 6.5 8.3 0.7 9.9 6.5 8.2 0.6 9.9 6.1 342 5 343 165 -5.2 0.1 -5 -5.3 01/02/2007 14:00:00 8.5 0.9 11.1 5.3 8.5 1.1 11.1 4.6 8.4 1 10.3 5.3 340 7 338 165 -5.2 0 -5 -5.5 01/02/2007 14:10:00 8.8 0.9 10.7 6.1 8.6 1.2 11.1 3.8 8.8 0.8 10.7 5.7 341 7 331 165 -5.2 0 -5 -5.3 01/02/2007 14:20:00 7.8 1 10.3 5.3 7.3 1.3 10.3 4.2 7.7 1 10.3 5.7 341 10 338 165 -5.2 0 -5 -5.3 01/02/2007 14:30:00 8.4 1 10.7 5.7 8.2 1.3 11.1 3.4 8.4 1 11.1 6.1 343 7 333 165 -5.2 0 -5 -5.3 01/02/2007 14:40:00 8.5 1.2 11.8 5.7 7.9 1.6 11.8 3.4 8.5 1.3 11.8 5.3 343 10 335 165 -5.2 0 -5 -5.5 01/02/2007 14:50:00 9 1.1 11.8 5.7 8.7 1.5 12.6 3.8 8.9 1.2 11.8 5.7 343 8 338 165 -5.2 0 -5 -5.5 01/02/2007 15:00:00 8.8 1.2 12.6 5.7 8.5 1.6 12.6 3.4 8.8 1.3 12.6 6.1 345 7 339 165 -5.4 0 -5 -5.7 01/02/2007 15:10:00 7.4 0.9 9.5 4.9 7.2 1.1 9.5 3.4 7.2 0.9 9.9 4.9 336 12 338 165 -5.5 0 -5.3 -5.7 01/02/2007 15:20:00 7.4 1.5 10.7 3.4 7.1 1.5 11.1 3.4 7.3 1.5 11.8 4.2 341 9 357 165 -5.6 0 -5.5 -5.7 01/02/2007 15:30:00 8 1.2 10.7 4.9 8 1.2 10.3 4.2 8.1 1.2 10.7 4.6 338 8 344 165 -5.5 0 -5.5 -5.7 01/02/2007 15:40:00 7.5 1 10.3 4.9 7.3 1.2 10.7 2.6 7.7 1 11.1 4.9 341 8 349 165 -5.6 0 -5.5 -5.7 01/02/2007 15:50:00 8.1 1.2 10.7 5.3 7.8 1.3 10.7 4.2 8 1.3 11.5 4.9 338 10 359 165 -5.7 0 -5.5 -5.7 01/02/2007 16:00:00 7.2 1 9.5 3.8 7.1 1 9.9 3.8 7.2 0.9 9.1 3.8 335 8 348 165 -5.6 0 -5.5 -5.7 01/02/2007 16:10:00 7.5 1.2 9.9 4.2 7.2 1.2 10.3 3.8 7.3 1.1 9.9 4.2 338 11 341 165 -5.6 0 -5.5 -5.7 01/02/2007 16:20:00 6.8 1.2 9.9 4.2 6 1.7 10.3 2.6 6.9 1.2 9.9 3.8 347 11 334 165 -5.7 0 -5.5 -5.7 01/02/2007 16:30:00 6.8 1.2 9.9 2.3 6.2 1.3 9.1 1.5 6.8 1.2 9.9 3.8 343 11 359 165 -5.8 0 -5.5 -5.9 01/02/2007 16:40:00 7.5 0.9 10.3 5.3 7 1.2 10.7 3.8 7.5 0.9 9.9 5.3 344 8 349 165 -5.8 0 -5.7 -5.9 01/02/2007 16:50:00 8.3 0.9 10.3 5.3 7.8 1.1 10.7 3.4 8.4 1 10.3 5.7 343 9 353 165 -5.9 0 -5.7 -6.1 01/02/2007 17:00:00 6.3 1.1 9.1 3.8 6.1 1.2 9.1 3 6.3 1.1 9.9 4.2 339 9 344 165 -5.9 0 -5.7 -6.1 01/02/2007 17:10:00 6.6 0.9 8.8 4.2 6.4 1.2 9.1 3 6.7 0.9 9.1 4.6 343 8 342 165 -6 0 -5.7 -6.1 01/02/2007 17:20:00 7.2 1 9.1 4.6 7 1.2 9.1 3.4 7 1 9.1 4.6 340 8 335 165 -6.1 0 -5.9 -6.4 01/02/2007 17:30:00 7.2 1.4 11.1 3.8 7.1 1.4 10.7 3.8 7.1 1.4 11.5 4.2 335 8 338 165 -6.1 0 -5.9 -6.1 01/02/2007 17:40:00 7.2 1.3 9.9 4.2 6.9 1.2 10.3 3 7.1 1.4 9.9 3.4 337 17 352 165 -6.2 0 -5.9 -6.4 01/02/2007 17:50:00 6.8 0.8 8.8 4.6 6.8 0.9 9.1 4.9 6.5 1 8.8 3.8 319 15 307 165 -6.2 0 -6.1 -6.4 01/02/2007 18:00:00 6.8 0.8 9.1 4.9 6.6 0.7 9.1 4.6 6 0.9 8 4.2 308 9 319 165 -6.3 0.1 -6.1 -6.4 01/02/2007 18:10:00 7.5 0.9 9.5 5.3 7.4 0.8 9.5 4.9 6.2 0.9 9.5 4.2 304 6 301 165 -6.4 0 -6.1 -6.6 01/02/2007 18:20:00 7.7 0.8 9.1 5.7 7.6 0.7 9.1 5.3 6.4 0.6 8.4 4.6 304 6 303 165 -6.5 0 -6.4 -6.6 01/02/2007 18:30:00 6.8 1 8.8 4.2 6.7 1 8.8 3.8 6.5 1.1 10.3 3.4 321 11 313 165 -6.5 0 -6.1 -6.8 01/02/2007 18:40:00 7.1 0.7 8.8 4.9 7 0.7 8.8 4.9 6.6 1 8.8 4.6 315 17 333 165 -6.5 0 -6.4 -6.6 01/02/2007 18:50:00 6.7 0.8 8.8 4.6 6.6 0.8 8.8 4.6 6.2 0.9 8.8 4.2 317 14 343 165 -6.7 0 -6.6 -6.8 01/02/2007 19:00:00 6.2 0.9 8.8 4.2 5.7 0.8 8 3.4 6 0.8 8.4 4.2 334 16 351 165 -6.7 0 -6.6 -6.8 01/02/2007 19:10:00 6.2 1.1 9.9 4.2 6.1 1.1 9.9 4.2 5.8 1 9.1 3.8 317 11 307 165 -6.7 0 -6.6 -6.8 01/02/2007 19:20:00 8.6 1 11.5 6.1 8.5 1 11.1 5.7 7.7 1.1 10.7 4.9 308 11 295 165 -6.8 0 -6.6 -7 01/02/2007 19:30:00 8.4 1.1 11.8 4.6 8.2 1.1 11.5 4.6 6.8 1 9.1 4.6 304 8 297 165 -6.9 0 -6.6 -7 01/02/2007 19:40:00 8.8 1.2 11.8 5.7 8.7 1.2 11.8 5.7 7.2 1 9.9 4.6 302 9 290 165 -7 0 -6.8 -7.2 01/02/2007 19:50:00 8.8 1.2 11.8 5.7 8.7 1.2 11.5 5.7 7.4 1.4 12.2 3.4 303 10 307 165 -7.1 0 -6.8 -7.2 01/02/2007 20:00:00 8.4 0.9 10.3 6.1 8.3 0.9 10.3 6.1 7.5 1.2 10.3 4.9 308 6 306 165 -7.3 0.1 -7 -7.6 01/02/2007 20:10:00 7.9 0.7 9.9 6.1 7.8 0.7 9.9 5.7 7.6 0.9 9.5 5.3 314 8 313 165 -7.5 0 -7.2 -7.6 01/02/2007 20:20:00 8.1 0.8 9.9 6.1 8 0.8 9.9 6.1 7.8 0.8 9.5 5.7 317 11 310 165 -7.6 0 -7.4 -7.9 01/02/2007 20:30:00 10.2 1 13 7.6 10 1 12.6 7.6 8.9 1 11.5 6.5 309 6 301 165 -7.6 0 -7.4 -8.1 01/02/2007 20:40:00 9.5 0.9 11.8 6.8 9.4 0.9 11.5 6.5 8.3 1 11.1 6.1 308 7 301 165 -8 0 -7.6 -8.1 01/02/2007 20:50:00 10.2 0.8 13 7.6 10.1 0.8 12.2 7.2 8.8 1.1 11.5 6.1 307 8 305 165 -8.1 0 -7.9 -8.3 01/02/2007 21:00:00 11 0.8 12.6 8.8 10.8 0.8 12.6 8 9.1 1.2 12.6 6.1 305 6 309 165 -8.2 0 -8.1 -8.5 01/02/2007 21:10:00 12.4 1 14.5 9.5 12.2 1 14.5 9.5 10.3 1.1 13.3 7.2 305 6 303 165 -8.4 0.1 -8.1 -8.5 01/02/2007 21:20:00 12.3 1.1 14.9 9.5 12.1 1.1 14.9 9.5 10.1 1.2 13.7 7.2 304 7 302 165 -8.6 0 -8.5 -8.7 01/02/2007 21:30:00 12.6 0.8 14.5 9.1 12.5 0.8 14.1 9.1 9.9 1.1 13 6.8 303 6 300 165 -8.6 0 -8.5 -8.9 01/02/2007 21:40:00 12.7 0.9 14.9 10.3 12.6 1 15.3 9.9 9.4 1 12.6 7.2 301 6 282 165 -8.6 0 -8.5 -8.9 01/02/2007 21:50:00 13.3 0.9 15.6 10.3 13.2 0.9 15.3 10.3 9.3 0.9 13 7.2 299 6 300 165 -8.7 0 -8.5 -8.9 01/02/2007 22:00:00 12.8 0.9 14.5 9.1 12.7 1 14.1 9.1 9.4 1 12.6 6.8 297 7 301 165 -8.8 0 -8.5 -8.9 01/02/2007 22:10:00 13.6 0.8 15.3 11.1 13.5 0.8 15.3 11.1 9.6 0.9 13 7.6 297 6 297 165 -8.9 0 -8.7 -9.1 01/02/2007 22:20:00 13.5 1 16.1 10.7 13.3 1 15.3 10.7 9.7 1 13 7.2 299 8 297 165 -9 0 -8.9 -9.1 01/02/2007 22:30:00 13.3 1.1 15.3 9.5 13.2 1.1 15.3 9.5 9.9 1 13.3 8 299 9 303 165 -9.1 0.1 -8.9 -9.3 01/02/2007 22:40:00 13.1 0.8 14.9 10.7 13 0.8 14.9 10.3 9.3 1.1 13.3 7.2 296 9 297 165 -9.1 0 -9.1 -9.3 01/02/2007 22:50:00 12.7 1.1 16.8 9.9 12.6 1.1 16.1 9.5 9.6 1.2 13.3 7.2 298 8 299 165 -9.1 0 -8.9 -9.3 01/02/2007 23:00:00 13 1.1 15.3 9.5 12.9 1.1 15.3 9.9 9.4 1 12.6 7.2 297 9 297 165 -9.3 0 -9.1 -9.5 01/02/2007 23:10:00 14.3 0.9 16.1 11.8 14.1 0.9 16.4 11.1 10.2 1.1 15.6 7.2 296 8 300 165 -9.4 0.1 -9.1 -9.7 01/02/2007 23:20:00 14.7 1 16.8 11.1 14.5 1.1 16.4 11.1 10.9 1.3 16.1 7.2 297 10 294 165 -9.6 0 -9.3 -9.7 01/02/2007 23:30:00 14.2 1.2 16.8 10.7 14.1 1.2 16.8 11.1 10.5 1.2 13.3 7.2 294 10 293 165 -9.6 0 -9.3 -9.7 01/02/2007 23:40:00 14.3 1.5 17.6 10.7 14.2 1.5 16.8 10.7 11.2 1.5 17.2 8.4 298 10 291 165 -9.6 0 -9.3 -9.7 01/02/2007 23:50:00 15.2 1.1 17.9 11.5 15.1 1.1 17.6 11.1 11.4 1.5 16.1 7.6 299 8 307 165 -9.3 0 -9.1 -9.5 01/03/2007 00:00:00 13.7 1.1 16.1 10.3 13.5 1.2 16.1 9.5 10 1.1 14.1 7.2 297 8 296 165 -9.5 0.1 -9.3 -9.7 01/03/2007 00:10:00 11.8 1 14.5 8.4 11.7 1 13.7 8.8 8.6 1.1 12.6 6.5 295 8 296 165 -9.8 0 -9.5 -10.2 01/03/2007 00:20:00 12.1 0.7 13.7 10.3 12 0.7 13.7 9.9 8.5 0.8 11.8 6.1 296 8 286 165 -10 0 -9.7 -10.2 01/03/2007 00:30:00 13.2 1.2 16.1 10.7 13.1 1.2 16.1 10.3 9.2 1.3 12.6 6.5 293 8 293 165 -10.3 0 -10.2 -10.6 01/03/2007 00:40:00 14.2 1 16.1 11.8 14.2 1 16.1 11.5 9.9 1 13.7 7.6 294 8 296 165 -10.5 0 -10.4 -10.6 01/03/2007 00:50:00 14 1 16.1 10.7 13.9 1 16.1 10.3 10 1 13 7.6 292 10 295 165 -10.6 0.1 -10.6 -10.8 01/03/2007 01:00:00 14.4 1.5 17.2 10.3 14.3 1.5 16.8 10.3 10.7 1.1 14.1 8 292 11 296 165 -10.8 0 -10.6 -11 01/03/2007 01:10:00 13.6 1.2 16.4 10.3 13.5 1.2 16.4 10.7 10.8 1.4 14.5 7.6 298 11 296 165 -11 0 -10.8 -11.4 01/03/2007 01:20:00 14.1 1.2 16.8 10.7 14 1.3 16.4 11.1 11.9 1.4 16.1 8.4 302 9 306 165 -11.1 0 -11 -11.4 01/03/2007 01:30:00 13.3 1 15.6 10.3 13.2 1 15.6 10.7 11.4 1.3 14.9 8.4 304 8 306 165 -11.2 0.1 -11 -11.4 01/03/2007 01:40:00 13.7 1 16.4 10.3 13.5 1 16.4 10.7 11.7 1.5 14.9 7.2 306 7 308 165 -11.3 0 -11.2 -11.6 01/03/2007 01:50:00 13.8 1 16.4 9.5 13.7 1 16.1 9.5 11.1 1.4 14.5 8 302 8 301 165 -11.3 0 -11.2 -11.6 01/03/2007 02:00:00 13.4 1.3 16.4 9.9 13.2 1.4 15.6 9.5 10.6 1.2 13.7 7.2 301 10 300 165 -11.5 0 -11.4 -11.8 01/03/2007 02:10:00 12.6 1.5 16.4 9.1 12.4 1.5 16.1 9.1 11 1.7 15.3 7.2 304 10 302 165 -11.6 0 -11.4 -11.8 01/03/2007 02:20:00 11.8 1.4 15.3 7.2 11.6 1.4 14.9 7.2 10.2 1.3 14.5 7.2 304 11 305 165 -11.6 0 -11.4 -11.8 01/03/2007 02:30:00 12.1 1.4 15.6 9.5 12 1.3 15.6 8.8 10.9 1.3 14.5 7.6 307 9 305 165 -11.6 0 -11.4 -11.8 01/03/2007 02:40:00 12.7 1.1 15.3 9.9 12.4 1.1 14.9 9.5 11.7 1.2 14.9 8.4 310 6 310 165 -11.6 0 -11.4 -11.8 01/03/2007 02:50:00 13.1 0.9 15.3 10.3 12.9 0.9 14.9 10.3 11 1 13.3 8.8 306 6 306 165 -11.5 0.1 -11.4 -11.8 01/03/2007 03:00:00 12.7 1 15.6 9.9 12.5 1 15.6 9.9 10.8 1.1 13.3 8 305 7 304 165 -11.3 0 -11.2 -11.6 01/03/2007 03:10:00 12.6 0.8 14.5 10.3 12.4 0.9 14.5 9.9 10.5 1.2 13.7 8 303 10 304 165 -11.3 0 -11 -11.4 01/03/2007 03:20:00 13 1 15.3 10.3 12.9 1 14.9 9.9 10.6 1.2 14.1 7.6 303 7 302 165 -11.3 0 -11 -11.4 01/03/2007 03:30:00 11.8 1 14.5 8.8 11.6 1 14.9 8.8 9.2 1.1 12.6 6.5 298 10 305 165 -11.5 0.1 -11.4 -11.8 01/03/2007 03:40:00 12.7 1.2 15.3 10.3 12.5 1.1 15.3 9.9 10.5 1.5 14.9 7.6 303 9 304 165 -11.7 0 -11.6 -11.8 01/03/2007 03:50:00 13 1 14.9 9.9 12.8 1 14.9 9.9 11.4 1.1 14.1 8.4 307 8 305 165 -11.6 0 -11.6 -11.8 01/03/2007 04:00:00 14.7 0.9 16.8 11.8 14.5 0.9 16.4 11.8 12.3 1.2 16.1 9.1 305 7 305 165 -11.7 0 -11.4 -11.8 01/03/2007 04:10:00 14 1.1 16.4 11.1 13.9 1.1 16.1 11.1 11.5 1.3 15.3 8 302 8 301 165 -11.8 0 -11.6 -11.8 01/03/2007 04:20:00 13.4 1 15.3 9.9 13.3 1 15.6 9.5 11.5 1.4 14.9 7.6 305 9 294 165 -11.9 0 -11.8 -12 01/03/2007 04:30:00 13.1 1 15.3 10.7 12.9 1 15.3 10.3 11.4 1.1 14.5 8.4 305 9 310 165 -11.9 0 -11.8 -12.2 01/03/2007 04:40:00 14.1 1 16.8 11.8 13.9 1.1 16.4 11.8 12.1 1.2 14.9 8.8 304 7 305 165 -11.9 0 -11.8 -12.2 01/03/2007 04:50:00 13.6 1.1 15.6 9.9 13.4 1.1 15.6 10.3 11.3 1.5 14.9 8 304 7 303 165 -12 0 -11.8 -12.2 01/03/2007 05:00:00 13.4 1.1 16.1 10.7 13.2 1.1 16.1 10.7 10.6 1.3 13.7 7.6 300 9 297 165 -11.9 0 -11.8 -12.2 01/03/2007 05:10:00 14.5 1.1 17.2 10.3 14.4 1.1 16.8 9.9 11 1.2 14.1 7.6 299 10 301 165 -11.9 0 -11.8 -12.2 01/03/2007 05:20:00 15.5 0.9 17.6 13 15.4 0.9 17.6 13 10.9 1.2 14.9 8 296 10 273 165 -11.9 0 -11.8 -12.2 01/03/2007 05:30:00 15.3 1.1 17.6 11.5 15.3 1.1 17.6 11.1 11.4 1.6 16.1 8 291 8 297 165 -11.9 0 -11.8 -12.2 01/03/2007 05:40:00 14.9 1.1 17.2 12.2 14.8 1.2 17.6 11.8 11.6 1.8 16.8 8 289 8 288 165 -11.8 0 -11.6 -12 01/03/2007 05:50:00 14.5 1.2 17.2 11.8 14.4 1.2 17.6 11.5 11.2 2.3 17.6 7.6 290 9 285 165 -11.9 0 -11.6 -12.2 01/03/2007 06:00:00 15.6 0.8 18.3 13.3 15.7 0.9 18.3 13 14.4 1.7 17.6 9.9 282 8 281 165 -11.8 0.1 -11.6 -12.2 01/03/2007 06:10:00 15.3 1.1 17.6 13 15.4 1.1 17.9 13 14.1 1.7 17.6 8.8 283 6 285 165 -12.1 0 -11.8 -12.4 01/03/2007 06:20:00 14.7 1 17.2 11.5 14.8 1 17.2 11.5 13.5 1.5 16.4 8.8 283 6 285 165 -12.2 0 -12.2 -12.4 01/03/2007 06:30:00 12.2 1.2 16.1 8.8 12.2 1.2 16.1 9.1 11.2 1.6 14.1 6.8 282 10 284 165 -12.1 0.2 -11.6 -12.4 01/03/2007 06:40:00 13.7 1.7 17.9 9.5 13.6 1.7 17.9 9.5 11.4 2.1 17.2 7.2 286 11 278 165 -11.6 0 -11.4 -11.8 01/03/2007 06:50:00 14.4 1.4 17.6 9.9 14.3 1.5 17.6 9.9 11.5 1.9 16.8 7.2 288 10 265 165 -11.5 0 -11.4 -11.8 01/03/2007 07:00:00 14.6 2.1 18.3 9.5 14.5 2.1 18.3 9.1 11.7 1.8 16.8 7.2 290 11 296 165 -11.5 0 -11.4 -11.8 01/03/2007 07:10:00 14.6 1.3 16.8 10.7 14.6 1.3 17.6 10.3 12.3 1.8 17.2 7.2 285 9 285 165 -11.7 0.1 -11.4 -11.8 01/03/2007 07:20:00 12.9 1.1 16.4 9.1 12.9 1.2 16.8 9.5 10.9 1.8 15.6 6.8 284 10 275 165 -11.7 0 -11.4 -12 01/03/2007 07:30:00 12.3 1.2 16.1 9.5 12.4 1.2 16.1 9.5 11.5 1.5 15.3 7.2 282 8 272 165 -11.6 0 -11.4 -11.8 01/03/2007 07:40:00 13.9 1.4 17.2 10.3 13.9 1.4 17.2 9.9 12.4 1.7 16.8 7.6 283 8 286 165 -11.6 0 -11.4 -11.8 01/03/2007 07:50:00 11.2 1.4 14.5 7.6 11.2 1.5 14.5 7.6 10 2 14.5 5.7 289 9 295 165 -11.8 0.1 -11.4 -12 01/03/2007 08:00:00 9.4 1.6 14.1 6.5 9.3 1.7 14.1 6.8 8 2 14.5 5.3 291 11 274 165 -12 0.1 -11.8 -12.2 01/03/2007 08:10:00 12.5 1.2 15.6 8.4 12.6 1.3 15.6 8 11.4 2 15.6 6.5 282 9 281 165 -12.3 0.2 -11.8 -12.6 01/03/2007 08:20:00 11.8 1.5 14.9 7.6 12.3 1.5 15.3 8 11.7 1.5 15.3 6.5 275 6 277 165 -12.6 0 -12.4 -13 01/03/2007 08:30:00 10.3 1.6 14.9 5.7 10.6 1.4 14.9 7.2 10 1.6 14.9 6.5 276 9 281 165 -12.9 0.1 -12.6 -13.2 01/03/2007 08:40:00 11.1 2.1 16.1 6.5 11.7 1.7 16.1 7.2 10.9 1.7 15.3 7.2 275 8 283 165 -13.1 0 -13 -13.2 01/03/2007 08:50:00 13.5 1.5 16.8 8 13.5 1.6 17.2 8 12.4 2 17.2 7.6 281 8 281 165 -13 0 -12.8 -13.2 01/03/2007 09:00:00 13.1 1.7 17.2 8.4 13.1 1.7 16.8 8.4 10.9 2.3 16.8 6.5 286 13 280 165 -13.1 0 -13 -13.6 01/03/2007 09:10:00 10.7 2.1 15.6 6.1 10.6 2.1 16.1 6.1 9.1 2.1 15.6 4.9 294 16 274 165 -13.1 0.1 -12.6 -13.6 01/03/2007 09:20:00 11.5 2.2 16.8 6.1 11.5 2.2 16.4 6.5 9.5 2 14.9 4.9 288 12 278 165 -13 0.2 -12.6 -13.4 01/03/2007 09:30:00 11.5 1.6 15.3 7.6 11.5 1.6 14.9 7.2 9.9 1.8 14.1 5.7 286 10 291 165 -13.3 0 -13 -13.6 01/03/2007 09:40:00 10.6 1.2 13.3 6.5 10.6 1.2 13.3 6.8 9.1 1.7 13.3 4.9 284 10 264 165 -13.5 0 -13.2 -13.6 01/03/2007 09:50:00 11.5 1.4 14.1 7.2 11.5 1.5 14.5 7.2 10.6 1.8 14.5 5.3 283 8 282 165 -13.5 0 -13.4 -13.8 01/03/2007 10:00:00 11 1.7 14.5 6.1 11.3 1.5 14.5 7.2 10.7 1.6 14.5 6.8 276 10 281 165 -13.8 0 -13.6 -14 01/03/2007 10:10:00 9.8 1.7 13.7 6.1 10.1 1.7 14.1 5.7 9.7 1.7 13.7 4.9 274 9 278 165 -13.8 0 -13.6 -14 01/03/2007 10:20:00 9.5 1.5 13 4.9 10.3 1.3 13 6.5 9.8 1.4 13 5.7 271 9 278 165 -13.7 0 -13.6 -14 01/03/2007 10:30:00 9.3 1.4 12.2 5.7 9.9 1.2 12.6 6.5 9.3 1.2 11.8 5.7 274 6 278 165 -13.6 0.1 -13.4 -14 01/03/2007 10:40:00 6.9 1.6 11.5 2.6 7.9 1.4 11.5 3.8 7.3 1.3 10.3 3.8 267 9 277 165 -13.5 0 -13.2 -13.6 01/03/2007 10:50:00 8.6 1.6 13 4.9 9.6 1.5 13 5.7 9 1.5 12.6 5.3 270 9 270 165 -13.1 0.1 -12.6 -13.6 01/03/2007 11:00:00 9.7 1.7 14.1 5.7 10.4 1.4 13.7 6.8 9.7 1.5 13.3 5.3 272 8 272 165 -12.7 0 -12.6 -13 01/03/2007 11:10:00 10.8 2.2 18.3 6.5 10.9 2.1 17.9 6.8 9.9 2 17.2 6.1 279 10 282 165 -12.6 0 -12.4 -13 01/03/2007 11:20:00 15.4 1.9 19.1 9.5 15.4 2 19.5 8.8 14.1 2.7 19.5 8 281 11 283 165 -12.6 0.2 -12.2 -13 01/03/2007 11:30:00 16 1.6 19.9 11.1 16 1.6 20.2 10.7 14.2 2.3 20.2 8.8 281 11 278 165 -12.9 0 -12.6 -13.2 01/03/2007 11:40:00 13.4 2.2 19.5 9.5 13.4 2.1 19.9 9.9 12 2.2 18.3 7.6 283 12 288 165 -13 0 -12.8 -13.2 01/03/2007 11:50:00 8.5 1.4 13 4.6 9.2 1.3 13.3 6.1 8.9 1.2 13.3 5.3 271 8 272 165 -13.1 0 -13 -13.4 01/03/2007 12:00:00 6.5 2.1 12.2 1.1 7.3 2.2 12.2 1.5 7.1 2.2 12.2 1.5 263 11 256 165 -13 0 -12.6 -13.2 01/03/2007 12:10:00 5.8 1.3 9.1 2.3 5.8 1.3 9.1 2.3 6 1.3 9.1 3 223 30 257 165 -12.8 0.2 -12.4 -13.2 01/03/2007 12:20:00 5.6 1.3 8.4 2.6 5.6 1.3 8.4 2.3 5.6 1.3 8.4 2.6 214 27 228 165 -12.3 0.1 -12.2 -12.6 01/03/2007 12:30:00 6.5 2.2 13 1.5 7.1 2.3 13 1.9 6.7 2.3 12.2 1.1 266 18 252 165 -12.6 0.1 -12.2 -13 01/03/2007 12:40:00 7.5 1.7 13.7 3.8 8.2 1.6 14.9 5.3 8.1 1.5 13 4.9 265 11 266 165 -12.8 0 -12.6 -13 01/03/2007 12:50:00 8.1 2.1 13 3.4 8.7 2.2 13.7 3.4 8.3 2.2 13.3 3.4 264 19 280 165 -12.8 0.1 -12.4 -13 01/03/2007 13:00:00 9.2 1.9 14.9 4.6 10.1 1.4 14.9 7.2 9.5 1.3 13.3 6.1 272 12 283 165 -12.8 0 -12.6 -13 01/03/2007 13:10:00 11.9 2.3 16.8 6.5 11.9 2.3 16.8 6.5 10.7 2.5 17.6 5.3 282 12 280 165 -13 0 -12.6 -13.2 01/03/2007 13:20:00 14.6 1.9 19.1 8.8 14.6 2 19.5 9.5 13.3 2.5 19.1 8 278 13 256 165 -13.1 0 -13 -13.4 01/03/2007 13:30:00 13.7 2.1 17.9 6.5 13.7 2.1 17.9 6.5 11.7 2.2 17.9 7.2 285 13 279 165 -13.1 0 -13 -13.4 01/03/2007 13:40:00 12.9 1.7 17.2 8 12.8 1.7 16.8 7.6 11 1.8 15.3 6.1 284 15 292 165 -13 0 -12.8 -13.2 01/03/2007 13:50:00 14.5 1.7 18.7 8 14.4 1.8 18.3 8 11.8 2 17.2 7.2 288 15 283 165 -13 0 -12.8 -13.2 01/03/2007 14:00:00 12 2.3 16.8 6.8 11.9 2.3 16.8 6.5 9.8 2 14.5 5.3 290 15 274 165 -12.8 0 -12.6 -13.2 01/03/2007 14:10:00 9.8 1.7 14.5 5.3 9.7 1.7 14.1 5.7 8.1 1.7 13 4.6 291 15 304 165 -12.6 0.1 -12.2 -13 01/03/2007 14:20:00 10.3 2.4 15.3 4.2 10.3 2.4 15.3 4.6 9.4 2.3 15.3 3.8 287 17 287 165 -12.6 0.1 -12.4 -12.8 01/03/2007 14:30:00 10.5 1.9 15.6 6.1 10.4 1.8 15.3 6.1 9 1.9 14.5 4.2 291 17 282 165 -12.8 0 -12.6 -13 01/03/2007 14:40:00 9.8 1.8 14.9 4.9 9.7 1.8 15.3 5.3 8.4 1.9 13 4.9 290 15 289 165 -12.9 0 -12.6 -13.2 01/03/2007 14:50:00 10.6 1.6 14.5 5.7 10.6 1.6 14.9 6.5 9.4 1.8 14.5 5.3 284 12 282 165 -13 0 -12.6 -13.2 01/03/2007 15:00:00 10.5 1.5 14.9 6.8 10.5 1.5 14.9 6.8 9.5 1.8 14.5 5.3 284 11 279 165 -13 0 -12.8 -13.2 01/03/2007 15:10:00 8.9 1.3 11.8 4.9 9 1.3 11.8 5.7 8.5 1.5 12.6 5.3 278 9 285 165 -12.9 0 -12.6 -13.2 01/03/2007 15:20:00 7.4 1.6 11.1 2.6 7.5 1.6 10.7 3 7 1.8 11.5 3 281 9 269 165 -12.9 0 -12.6 -13.2 01/03/2007 15:30:00 9.3 1.9 13.7 5.7 9.3 2 13.7 5.3 8.3 2 13.3 4.6 281 12 274 165 -13 0 -12.8 -13.2 01/03/2007 15:40:00 10.6 1 14.1 7.2 10.7 1 14.1 7.2 9.7 1.5 13.7 5.3 279 10 261 165 -13.2 0 -13 -13.4 01/03/2007 15:50:00 9.5 1.4 13 5.3 9.5 1.5 13.3 5.3 8.2 2 13 4.6 286 15 268 165 -13.3 0 -13.2 -13.6 01/03/2007 16:00:00 7.4 1.4 9.9 3.8 7.4 1.5 9.9 3.8 6.3 1.3 10.7 3.8 292 17 287 165 -13.5 0 -13.2 -13.6 01/03/2007 16:10:00 7.7 1.2 11.8 4.2 7.6 1.3 11.8 4.2 6.9 1.2 9.9 3.4 306 15 309 165 -13.7 0 -13.4 -14 01/03/2007 16:20:00 6.6 1.7 10.7 3 6.6 1.7 10.7 2.6 5.9 1.5 11.1 3 295 16 287 165 -14 0 -13.8 -14 01/03/2007 16:30:00 6.7 1.7 10.7 3.4 6.7 1.7 11.5 3 6.3 2 11.8 3 288 18 273 165 -13.9 0.1 -13.6 -14.2 01/03/2007 16:40:00 4.6 1.7 8 0.7 4.7 1.7 8.4 0.7 4.3 1.5 9.1 1.1 282 18 300 165 -14 0 -13.8 -14 01/03/2007 16:50:00 7.4 1.9 13.3 4.2 7.5 2.1 13.7 3.4 6.7 2.1 13.3 2.6 283 17 273 165 -14 0 -13.8 -14.2 01/03/2007 17:00:00 11.5 2.7 17.9 4.2 11.5 2.6 17.6 4.6 10.2 2.5 16.1 4.9 280 14 254 165 -14 0 -13.8 -14.2 01/03/2007 17:10:00 11.9 1.8 16.4 7.6 11.9 1.8 16.1 7.2 10 1.7 15.3 4.9 289 17 293 165 -14.1 0 -13.8 -14.2 01/03/2007 17:20:00 12.3 2.5 17.6 6.5 12.2 2.5 17.6 6.8 10.2 2.3 17.6 5.3 285 15 282 165 -14.1 0 -13.8 -14.2 01/03/2007 17:30:00 13 2.5 18.3 5.7 13 2.5 18.3 5.7 11.3 2.6 19.5 4.9 281 13 287 165 -14 0.1 -13.8 -14 01/03/2007 17:40:00 13.5 1.9 18.7 8 13.5 1.9 19.5 8.4 12.1 2.4 18.3 6.8 279 13 253 165 -14 0 -13.8 -14 01/03/2007 17:50:00 13.1 1.9 17.6 8.4 13 1.9 17.9 8.4 10.8 2 17.6 6.8 291 15 278 165 -14.1 0 -13.8 -14 01/03/2007 18:00:00 11.4 1.7 16.1 7.2 11.3 1.7 16.1 6.5 9.9 2 16.8 5.3 296 15 289 165 -14.1 0 -14 -14.4 01/03/2007 18:10:00 12.4 2.6 17.9 6.5 12.3 2.6 17.9 6.5 10.1 2.2 17.2 5.7 285 17 260 165 -14.1 0 -14 -14.2 01/03/2007 18:20:00 17.2 2.4 22.9 11.8 17 2.4 22.9 12.2 14 1.8 19.9 9.9 286 17 282 165 -14 0 -13.8 -14.2 01/03/2007 18:30:00 19.4 2.4 24.8 12.6 19.3 2.5 25.2 12.6 15.8 2.8 23.7 9.5 286 11 261 165 -14.1 0 -14 -14.2 01/03/2007 18:40:00 19.6 2.1 23.7 13 19.5 2.2 24 13 15.5 1.7 20.2 10.7 292 11 291 165 -14.1 0.1 -14 -14.6 01/03/2007 18:50:00 18.5 2.2 23.7 13.3 18.4 2.2 23.3 12.6 15.5 2.2 22.6 10.7 291 12 290 165 -13.9 0 -13.6 -14 01/03/2007 19:00:00 17.6 2.1 24 12.6 17.4 2.1 23.7 12.6 15.2 2.6 24 9.1 286 13 294 165 -13.8 0 -13.6 -14 01/03/2007 19:10:00 19 1.7 22.9 13.7 19 1.7 23.3 13.7 17.2 2.4 23.7 11.5 280 10 272 165 -13.6 0 -13.4 -13.8 01/03/2007 19:20:00 17.8 2.8 24.4 11.1 17.7 2.7 24 11.8 15 2.8 26 8.4 284 11 294 165 -13.4 0 -13.2 -13.8 01/03/2007 19:30:00 12.1 1.7 18.3 7.2 12.1 1.5 18.3 8.4 10.6 1.7 15.3 6.1 285 13 290 165 -13.5 0 -13.2 -13.6 01/03/2007 19:40:00 14.7 2 19.9 10.3 14.7 2.1 19.9 9.9 12.8 2.2 18.7 7.2 280 12 289 165 -13.5 0 -13.2 -13.6 01/03/2007 19:50:00 16 1.9 20.2 11.5 15.9 2 20.6 10.7 14.1 2.3 19.9 8.8 282 12 275 165 -13.3 0 -13.2 -13.6 01/03/2007 20:00:00 16.6 1.8 21.4 9.5 16.6 1.8 21.8 10.3 15.4 2.2 21 9.1 277 10 289 165 -13.1 0 -13 -13.6 01/03/2007 20:10:00 17.2 1.7 20.6 12.2 17.2 1.8 20.6 11.8 16.1 2.3 21.8 9.9 277 10 284 165 -13 0 -13 -13.2 01/03/2007 20:20:00 17.2 1.7 21.4 11.1 17.2 1.7 21.8 11.1 15.1 2.2 21.4 9.1 280 11 289 165 -13.1 0 -13 -13.2 01/03/2007 20:30:00 17.8 2.1 21.8 12.6 17.8 2.1 21.8 12.6 15.9 2.6 22.1 9.5 279 11 265 165 -13 0 -12.8 -13.2 01/03/2007 20:40:00 16.4 1.7 20.6 10.7 16.3 1.8 20.6 10.7 14.6 2.5 21 9.1 281 11 284 165 -13 0 -12.8 -13.4 01/03/2007 20:50:00 18.2 2.1 22.9 13.7 18.2 2.2 22.9 13.3 16.3 3.1 24 10.3 281 11 273 165 -13.1 0 -13 -13.6 01/03/2007 21:00:00 14.8 2.8 21 7.2 14.7 2.8 21 6.8 13.1 2.8 19.5 6.8 280 12 268 165 -13.2 0 -13 -13.6 01/03/2007 21:10:00 9.4 1.8 14.5 4.9 9.5 1.7 14.9 5.7 8.9 2 14.1 5.3 277 10 279 165 -13.1 0 -13 -13.6 01/03/2007 21:20:00 8.9 1.7 13.3 4.9 8.8 1.7 13.7 4.9 7.8 2 13.3 4.2 290 16 280 165 -13.2 0.1 -12.8 -13.6 01/03/2007 21:30:00 8.4 1.9 14.1 4.6 8.3 1.9 14.1 4.6 7.3 1.9 13.3 3.4 296 16 271 165 -13.5 0 -13.2 -13.8 01/03/2007 21:40:00 7.2 1.7 12.2 3 7.1 1.7 12.6 3 6.2 1.6 10.7 2.3 296 18 284 165 -13.4 0.1 -13 -13.6 01/03/2007 21:50:00 9.6 2.2 14.1 3.8 9.5 2.2 14.1 3.4 8.5 2.5 14.5 2.6 302 17 301 165 -13.6 0.1 -13.4 -13.8 01/03/2007 22:00:00 13.2 1.5 16.4 9.1 13 1.4 16.1 9.5 11.8 1.9 17.6 7.2 304 12 307 165 -13.5 0.1 -13.2 -13.8 01/03/2007 22:10:00 8 2.8 13.7 2.3 8 2.7 13.3 2.3 6.9 2.1 11.8 2.3 273 41 288 165 -13.6 0 -13.2 -13.8 01/03/2007 22:20:00 5.2 1.9 9.9 0.7 5.1 1.9 10.3 1.5 4.8 1.9 10.7 0.4 277 45 233 165 -13.4 0.1 -13.2 -13.6 01/03/2007 22:30:00 7.5 1.2 10.7 4.9 8 1.2 11.5 5.7 7.5 1.4 11.8 4.9 272 13 254 165 -13.3 0.1 -13 -13.6 01/03/2007 22:40:00 9.2 2 13.7 4.9 9.6 1.7 13.7 5.7 9.3 1.7 14.1 4.9 273 9 274 165 -13.4 0.1 -13.2 -13.6 01/03/2007 22:50:00 11.1 1 14.1 8 11.2 1 14.1 8.4 10.8 1.3 14.5 5.7 278 7 286 165 -13.6 0 -13.4 -13.8 01/03/2007 23:00:00 8.2 2.6 13 2.6 8.2 2.5 13 2.3 7 2.6 11.8 1.9 286 14 287 165 -13.8 0.1 -13.6 -14 01/03/2007 23:10:00 3.5 1.7 8 0.4 3.5 1.7 7.6 0.4 3 1.4 7.2 0.4 276 28 282 165 -14.1 0 -14 -14.2 01/03/2007 23:20:00 2 1.2 5.3 0.4 2 1.3 5.3 0.4 1.9 1 4.9 0.4 168 72 286 165 -14.1 0 -13.8 -14.4 01/03/2007 23:30:00 3.6 1 6.5 1.1 3.6 1 6.1 1.1 2.9 0.8 5.7 1.1 307 24 302 165 -14 0.1 -13.6 -14.2 01/03/2007 23:40:00 2.4 0.5 3.8 0.7 2.3 0.6 3.8 0.4 2.2 0.8 3.8 0.4 101 45 99 165 -14.1 0.1 -13.6 -14.6 01/03/2007 23:50:00 1.4 1.1 4.2 0.4 1.3 1.1 4.2 0.4 1.5 1.1 4.2 0.4 321 94 296 165 -13.6 0 -13.4 -14 01/04/2007 00:00:00 5 0.8 6.8 3 5 0.8 6.8 3 4.7 1 7.2 2.6 308 8 315 165 -13.8 0 -13.6 -14 01/04/2007 00:10:00 3.2 0.7 5.3 2.3 3.2 0.6 4.9 2.3 3.2 0.7 4.9 1.9 285 20 330 165 -14.1 0.1 -13.6 -14.4 01/04/2007 00:20:00 2.2 0.8 5.3 0.4 2.3 0.9 5.7 0.4 2.4 0.8 4.6 0.7 235 21 270 165 -13.6 0.1 -13.4 -13.8 01/04/2007 00:30:00 1.8 0.8 4.2 0.4 1.9 0.9 4.2 0.4 1.9 0.8 3.8 0.4 245 24 248 165 -13.6 0 -13.4 -13.8 01/04/2007 00:40:00 1.7 1 3.8 0.4 2 1.2 4.2 0.4 1.7 1.1 4.2 0.4 240 21 278 165 -13.8 0 -13.6 -14 01/04/2007 00:50:00 4.2 0.6 5.7 3 4.2 0.6 5.7 2.6 4.1 0.8 5.7 1.9 315 15 316 165 -14.2 0 -14 -14.6 01/04/2007 01:00:00 4.8 0.3 5.7 3.8 4.7 0.3 5.3 3.8 4.6 0.4 5.7 3.8 319 7 321 165 -14.8 0.2 -14.4 -15.2 01/04/2007 01:10:00 3.5 0.7 4.9 1.5 3.5 0.7 4.9 2.3 2.9 0.9 4.9 1.1 297 14 305 165 -14.8 0 -14.6 -15 01/04/2007 01:20:00 3 0.4 3.8 1.9 3 0.4 3.8 1.5 2.7 0.6 3.8 1.1 308 12 298 165 -14.8 0 -14.6 -15 01/04/2007 01:30:00 2.8 0.6 4.2 1.1 2.8 0.6 4.2 1.1 2.7 0.6 4.2 1.5 319 15 328 165 -14.4 0.2 -14 -15 01/04/2007 01:40:00 2.1 0.7 3.4 0.4 2 0.8 3.4 0.4 2.2 0.5 3 0.7 330 21 302 165 -14 0 -13.8 -14.2 01/04/2007 01:50:00 1 0.5 2.6 0.4 1 0.5 2.6 0.4 1.2 0.4 2.3 0.4 320 14 307 165 -14.1 0 -14 -14.2 01/04/2007 02:00:00 1.1 0.4 1.9 0.4 0.9 0.5 2.3 0.4 1.4 0.4 2.3 0.4 338 17 327 165 -14 0 -13.8 -14.4 01/04/2007 02:10:00 0.4 0.1 1.1 0.4 0.4 0.1 0.7 0.4 0.6 0.3 1.1 0.4 358 15 323 165 -14.1 0 -14 -14.4 01/04/2007 02:20:00 1.3 0.5 2.3 0.4 1.3 0.5 2.3 0.4 1.4 0.4 2.3 0.4 323 11 310 165 -14.4 0.1 -14 -14.6 01/04/2007 02:30:00 1.4 0.3 2.3 0.7 1.1 0.5 2.3 0.4 1.7 0.3 2.6 1.1 342 12 329 165 -14.6 0.1 -14.4 -14.8 01/04/2007 02:40:00 1 0.3 1.9 0.4 0.8 0.3 1.5 0.4 1.4 0.2 1.9 0.7 1 11 346 165 -14.5 0.1 -14.2 -14.8 01/04/2007 02:50:00 0.7 0.4 1.5 0.4 0.5 0.2 1.1 0.4 1.2 0.3 1.9 0.4 336 19 343 165 -14.5 0 -14.4 -14.6 01/04/2007 03:00:00 0.5 0.2 1.5 0.4 0.4 0.2 1.1 0.4 1.2 0.3 1.9 0.4 5 0 5 165 -14.5 0 -14.4 -14.6 01/04/2007 03:10:00 0.6 0.4 1.5 0.4 0.5 0.3 1.5 0.4 0.9 0.5 1.9 0.4 10 22 358 165 -14.4 0 -14.2 -14.6 01/04/2007 03:20:00 0.5 0.3 1.5 0.4 0.5 0.3 1.5 0.4 0.6 0.3 1.5 0.4 55 6 44 165 -14.3 0 -14 -14.6 01/04/2007 03:30:00 1.3 0.3 1.9 0.4 1.3 0.3 1.9 0.4 1.3 0.4 1.9 0.4 36 21 19 165 -14.2 0.1 -14 -14.6 01/04/2007 03:40:00 1.4 0.3 2.3 0.7 1.5 0.3 2.3 0.7 1.4 0.4 2.3 0.7 110 15 93 165 -13.8 0 -13.6 -14.2 01/04/2007 03:50:00 0.9 0.6 1.9 0.4 0.9 0.5 1.9 0.4 1 0.6 2.3 0.4 161 2 152 165 -13.6 0 -13.4 -14 01/04/2007 04:00:00 0.9 0.5 1.9 0.4 0.9 0.5 1.9 0.4 0.7 0.4 1.9 0.4 133 22 104 165 -13.7 0 -13.6 -14 01/04/2007 04:10:00 1.6 0.3 2.3 0.7 1.6 0.3 2.3 0.7 1.6 0.3 2.3 1.1 103 16 102 165 -13.5 0.1 -13.2 -13.8 01/04/2007 04:20:00 1 0.4 2.3 0.4 1 0.4 2.3 0.4 1 0.4 2.3 0.4 110 0 110 165 -13.5 0 -13.2 -13.8 01/04/2007 04:30:00 1.4 0.3 1.9 0.7 1.4 0.3 1.9 0.7 1.3 0.3 2.3 0.7 99 10 103 165 -13.2 0.2 -12.8 -14 01/04/2007 04:40:00 2.3 0.5 3 1.1 2.4 0.5 3 1.1 2.4 0.5 3.4 1.1 82 7 84 165 -12.9 0 -12.6 -13.2 01/04/2007 04:50:00 2.1 0.6 3 0.7 2.2 0.6 3.4 1.1 2 0.7 3.4 0.7 76 13 89 165 -13.2 0 -12.8 -13.6 01/04/2007 05:00:00 2 0.4 3 1.1 2 0.4 3 0.7 1.9 0.4 3 1.1 87 12 106 165 -13 0.1 -12.6 -13.4 01/04/2007 05:10:00 1.7 0.4 2.6 0.7 1.7 0.4 2.6 0.4 1.7 0.5 2.6 0.7 59 24 31 165 -13.1 0 -13 -13.2 01/04/2007 05:20:00 2.5 0.2 3 1.9 2.5 0.2 3 1.9 2.3 0.2 2.6 1.9 51 5 48 165 -13.1 0.1 -12.8 -13.6 01/04/2007 05:30:00 2.3 0.2 2.6 1.9 2.2 0.2 2.6 1.9 2.3 0.2 2.6 1.9 42 6 54 165 -13 0 -12.8 -13.2 01/04/2007 05:40:00 2.5 0.3 3 1.9 2.6 0.3 3.4 1.9 2.4 0.3 3.4 1.9 65 10 55 165 -12.9 0.1 -12.6 -13.2 01/04/2007 05:50:00 2 0.4 3.4 1.1 2 0.5 3.4 1.1 1.8 0.4 3 1.1 58 6 75 165 -12.7 0 -12.6 -13 01/04/2007 06:00:00 2.2 0.5 3.4 0.7 2.2 0.6 3.4 0.7 2.1 0.5 3.8 1.1 66 15 79 165 -12.6 0 -12.4 -13 01/04/2007 06:10:00 2.3 0.3 3 1.1 2.1 0.3 3 0.7 2.5 0.3 3 0.7 26 8 22 165 -12.6 0 -12.4 -12.6 01/04/2007 06:20:00 2.3 0.4 3.4 1.5 2.1 0.4 3 1.1 2.5 0.4 3.4 1.9 27 7 21 165 -12.6 0 -12.4 -13 01/04/2007 06:30:00 2.4 0.4 3.8 1.5 2.3 0.4 3.8 1.1 2.4 0.2 3 1.5 40 9 51 165 -12.4 0 -12.2 -12.6 01/04/2007 06:40:00 2.9 0.2 3.4 2.6 2.8 0.2 3.4 2.3 2.9 0.2 3.4 2.3 37 3 37 165 -12.4 0 -12.2 -12.6 01/04/2007 06:50:00 2.7 0.3 3.4 1.9 2.6 0.4 3.4 1.9 2.8 0.2 3.4 2.3 41 8 42 165 -12.2 0 -12 -12.4 01/04/2007 07:00:00 2.5 0.3 3.4 1.5 2.3 0.4 3.4 1.5 2.5 0.2 3 1.9 34 10 38 165 -12.1 0 -11.8 -12.2 01/04/2007 07:10:00 2.1 0.3 3.4 1.5 1.9 0.4 3.4 0.7 2.3 0.2 3 1.9 24 8 59 165 -12 0 -11.8 -12.2 01/04/2007 07:20:00 2.6 0.5 4.6 1.5 2.4 0.6 4.6 1.5 2.7 0.3 3.8 1.9 31 11 78 165 -11.9 0 -11.8 -12 01/04/2007 07:30:00 3.3 0.6 5.3 1.9 3.3 0.7 5.3 1.5 2.7 0.5 4.9 1.5 64 15 58 165 -11.6 0 -11.4 -12 01/04/2007 07:40:00 2.8 0.6 4.9 1.5 2.7 0.6 4.9 1.5 2.6 0.5 3.4 1.5 50 22 63 165 -11.5 0 -11.4 -11.8 01/04/2007 07:50:00 3.3 0.4 4.2 2.3 3.3 0.4 4.2 2.3 3.1 0.3 3.8 2.3 46 8 55 165 -11.3 0.1 -11.2 -11.6 01/04/2007 08:00:00 3.4 0.5 4.9 2.3 3.4 0.5 4.9 2.3 2.9 0.3 3.8 2.3 56 9 66 165 -11.2 0 -11 -11.4 01/04/2007 08:10:00 3.6 0.5 4.9 2.3 3.6 0.6 4.9 2.3 3.2 0.5 4.9 2.3 66 11 59 165 -11.1 0 -10.8 -11.4 01/04/2007 08:20:00 2.9 0.3 3.8 2.3 2.9 0.4 4.2 1.9 2.8 0.2 3.4 2.3 49 9 75 165 -11 0 -11 -11.2 01/04/2007 08:30:00 2.8 0.4 4.9 1.9 2.7 0.4 4.6 1.9 2.8 0.3 4.2 2.3 41 10 44 165 -10.9 0 -10.6 -11.2 01/04/2007 08:40:00 2.9 0.3 3.8 2.3 2.7 0.4 3.8 1.5 3 0.3 3.8 2.3 24 5 19 165 -10.8 0 -10.6 -11 01/04/2007 08:50:00 3.3 0.2 3.8 2.6 3.1 0.2 3.8 2.3 3.5 0.2 4.2 3 24 2 23 165 -10.6 0 -10.4 -11 01/04/2007 09:00:00 3.3 0.3 3.8 2.6 3.2 0.3 3.8 2.3 3.4 0.2 3.8 3 29 3 29 165 -10.4 0 -10.2 -10.6 01/04/2007 09:10:00 3.4 0.3 4.2 2.6 3.2 0.4 4.2 1.9 3.5 0.3 4.2 2.6 34 10 53 165 -10.3 0 -10.2 -10.6 01/04/2007 09:20:00 3.3 0.3 3.8 2.3 3.2 0.3 3.8 2.6 3.4 0.3 4.2 2.6 37 7 50 165 -10.2 0 -10 -10.4 01/04/2007 09:30:00 3.2 0.4 4.9 2.3 3.1 0.4 4.9 2.3 3.2 0.4 4.9 1.9 45 12 68 165 -10 0 -9.7 -10.2 01/04/2007 09:40:00 3.8 0.5 5.3 2.6 3.8 0.5 4.9 2.6 3.5 0.5 5.3 2.6 52 8 58 165 -9.9 0 -9.7 -10.2 01/04/2007 09:50:00 3.4 0.3 4.2 2.6 3.3 0.3 4.2 2.6 3.3 0.3 3.8 2.6 34 9 36 165 -9.7 0 -9.7 -10 01/04/2007 10:00:00 3.5 0.3 4.2 3 3.2 0.3 4.2 2.3 3.5 0.2 4.2 3 20 3 18 165 -9.6 0 -9.3 -10 01/04/2007 10:10:00 3.9 0.3 4.9 3 3.8 0.3 4.9 3 3.8 0.3 4.6 3 43 9 50 165 -9.4 0.1 -8.9 -9.7 01/04/2007 10:20:00 3.4 0.4 4.2 1.9 3.3 0.4 4.6 1.9 3.4 0.4 4.2 2.6 59 8 52 165 -9.1 0 -8.9 -9.3 01/04/2007 10:30:00 2.8 0.3 3.4 1.5 2.7 0.4 3.4 1.5 3 0.3 3.8 2.3 48 6 50 165 -8.9 0 -8.7 -9.3 01/04/2007 10:40:00 2.5 0.3 3.4 1.5 2.3 0.3 3 1.1 2.7 0.3 3.4 1.9 41 8 48 165 -8.8 0 -8.5 -9.1 01/04/2007 10:50:00 2.5 0.2 3 1.9 2.1 0.3 3 1.5 2.6 0.2 3 1.5 24 7 31 165 -8.7 0 -8.5 -8.9 01/04/2007 11:00:00 3.1 0.4 3.8 2.3 2.6 0.5 3.4 1.5 3 0.3 3.8 2.3 18 6 28 165 -8.7 0 -8.5 -8.9 01/04/2007 11:10:00 3.4 0.3 4.2 3 1.5 0.5 3 0.7 3.5 0.3 4.2 3 4 4 360 165 -8.6 0 -8.5 -8.7 01/04/2007 11:20:00 4.7 0.3 5.3 3.8 2.1 0.3 3 1.5 4.8 0.3 5.3 3.8 2 1 4 165 -8.4 0 -8.1 -8.7 01/04/2007 11:30:00 4.5 0.3 5.3 3.4 2.9 0.7 4.6 1.1 4.5 0.4 5.3 3.4 9 4 16 165 -8.1 0.1 -7.9 -8.3 01/04/2007 11:40:00 4.7 0.4 5.7 3.8 3.3 0.8 4.9 1.1 4.5 0.4 5.3 3.8 9 5 16 165 -8 0 -7.6 -8.1 01/04/2007 11:50:00 5.3 0.6 6.5 3.4 3.7 0.8 5.3 1.9 5.1 0.7 6.5 3.4 3 9 11 165 -7.9 0 -7.6 -8.1 01/04/2007 12:00:00 5.5 0.9 8 3.8 3.4 1 6.5 1.5 5.4 0.8 7.6 4.2 0 6 358 165 -7.8 0 -7.4 -8.1 01/04/2007 12:10:00 7 0.6 9.1 5.7 4.7 1.2 8 2.3 6.9 0.6 8.4 5.3 5 6 4 165 -7.6 0 -7.2 -7.9 01/04/2007 12:20:00 7.5 0.6 8.8 5.7 5.6 0.9 8 3.8 7.3 0.7 9.1 5.3 9 5 16 165 -7.5 0 -7.2 -7.6 01/04/2007 12:30:00 7.3 0.8 9.5 4.9 4.8 1 7.2 2.6 7.2 0.8 9.9 5.3 2 7 358 165 -7.3 0 -6.8 -7.6 01/04/2007 12:40:00 7.4 1 10.3 4.9 5.3 1.3 8.8 2.6 7.2 1 9.5 4.9 0 8 355 165 -7.2 0 -6.8 -7.4 01/04/2007 12:50:00 7.2 0.9 9.9 5.3 5.1 1.1 8.8 2.6 7 0.9 9.5 4.6 1 8 356 165 -7.3 0 -7.2 -7.4 01/04/2007 13:00:00 6.6 0.8 8.8 4.6 4.8 1 6.8 3 6.5 0.8 8.8 4.2 356 8 2 165 -7.2 0 -7 -7.4 01/04/2007 13:10:00 5.7 1 8 3.4 4.5 1.1 7.2 2.3 5.5 1 7.6 3.4 352 10 357 165 -7.3 0 -7.2 -7.4 01/04/2007 13:20:00 6.3 1.3 9.1 3 4.4 1.2 7.6 1.9 6.1 1.3 9.1 3 358 8 351 165 -7.3 0 -7 -7.4 01/04/2007 13:30:00 7 0.9 9.1 4.6 4.8 1 7.6 2.6 6.9 1 9.1 4.6 359 7 354 165 -7.2 0 -7 -7.4 01/04/2007 13:40:00 6.1 1 8.8 4.2 4.4 1.5 8.4 2.3 6.1 1 8.8 4.6 4 10 15 165 -7.2 0 -7 -7.4 01/04/2007 13:50:00 5.3 0.7 7.2 3.8 3.8 1 6.5 1.9 5.4 0.7 7.6 4.2 353 7 357 165 -7.1 0 -6.8 -7.2 01/04/2007 14:00:00 6.5 0.7 8.4 4.6 4.6 1.2 7.6 2.3 6.3 0.7 7.6 4.2 354 7 359 165 -7 0 -6.8 -7.2 01/04/2007 14:10:00 6.7 0.6 8 4.9 6 1 8 3 6.3 0.6 7.6 4.9 347 5 343 165 -7.1 0 -6.8 -7.2 01/04/2007 14:20:00 6.4 0.9 9.1 4.6 6 0.9 8 2.6 6.3 0.9 9.5 4.2 343 7 355 165 -7.2 0 -7 -7.4 01/04/2007 14:30:00 7.6 1.1 10.3 4.6 7.5 1.2 10.3 4.6 7.5 1.2 11.1 4.6 336 7 335 165 -7.2 0 -7 -7.4 01/04/2007 14:40:00 7.5 0.8 9.5 4.9 7.2 1 9.5 4.2 7.5 0.8 9.5 5.3 338 9 335 165 -7.2 0 -7 -7.2 01/04/2007 14:50:00 7.7 0.9 11.8 5.3 7.6 1 11.5 4.9 7.6 0.9 11.1 5.7 338 8 334 165 -7.2 0 -7 -7.2 01/04/2007 15:00:00 8.1 1 10.3 5.7 7.9 1.1 10.3 4.9 8 1 9.9 5.7 335 8 327 165 -7.2 0 -7 -7.4 01/04/2007 15:10:00 7.7 1 9.9 4.9 7.5 1 10.3 4.6 7.6 1 9.9 4.9 338 7 332 165 -7.2 0 -6.8 -7.4 01/04/2007 15:20:00 7.8 0.9 9.9 5.7 7.4 1.1 10.3 4.9 7.7 0.9 9.9 5.7 338 10 339 165 -7.2 0 -7 -7.2 01/04/2007 15:30:00 8.1 0.9 10.7 5.3 7.9 1 10.7 4.2 8 0.9 10.3 5.3 338 8 347 165 -7.2 0 -6.8 -7.4 01/04/2007 15:40:00 8.4 1 11.8 6.1 8.3 1.1 11.1 5.3 8.3 1.1 11.5 5.7 335 9 333 165 -7.1 0 -6.8 -7.2 01/04/2007 15:50:00 8.4 0.8 10.3 6.5 8.3 0.9 10.3 5.7 8.3 0.7 10.3 6.1 337 8 340 165 -7.2 0 -7 -7.4 01/04/2007 16:00:00 8.5 1.1 11.8 5.7 8.2 1.4 11.5 4.6 8.5 1.1 11.8 6.1 338 11 334 165 -7.2 0 -6.8 -7.2 01/04/2007 16:10:00 7.9 1.1 11.1 4.9 7.5 1.4 11.1 4.6 7.8 1.1 10.3 5.3 341 9 341 165 -7.2 0 -6.8 -7.2 01/04/2007 16:20:00 8.5 1.1 10.7 5.3 7.8 1.5 11.1 3.8 8.6 1.1 11.1 5.3 345 8 349 165 -7.2 0 -6.8 -7.4 01/04/2007 16:30:00 9 1 11.1 6.5 8.9 1.2 11.5 5.7 9.1 1.1 11.5 6.5 342 5 334 165 -7.2 0 -6.8 -7.4 01/04/2007 16:40:00 8.9 1 11.1 6.5 8.4 1.5 11.5 4.9 8.9 1 11.1 6.5 346 5 339 165 -7.2 0 -7 -7.4 01/04/2007 16:50:00 8.2 0.9 11.1 6.5 7.4 1.4 11.1 3.8 8.4 1 11.1 6.1 347 6 350 165 -7.3 0 -7 -7.4 01/04/2007 17:00:00 7.8 0.8 9.9 5.7 6.9 1.1 9.5 3.8 8 0.8 10.3 6.1 347 7 353 165 -7.3 0 -7.2 -7.4 01/04/2007 17:10:00 7.4 0.8 9.9 5.3 5.7 1.5 9.9 3.4 7.5 0.8 9.5 5.3 351 7 353 165 -7.2 0 -7 -7.4 01/04/2007 17:20:00 6.5 1.1 8.8 4.2 5.8 1.4 8.8 2.6 6.6 1 8.4 3.8 346 8 360 165 -7.3 0 -7.2 -7.4 01/04/2007 17:30:00 5 0.5 6.8 3.8 4.1 1 6.5 1.9 5.1 0.5 6.8 4.2 348 11 338 165 -7.2 0.1 -6.8 -7.4 01/04/2007 17:40:00 5.1 0.4 6.5 3.8 4.2 1 6.1 1.9 5.4 0.5 6.5 4.2 349 9 358 165 -7 0.1 -6.8 -7.2 01/04/2007 17:50:00 4.9 0.6 6.5 3.4 3.7 0.9 6.1 1.9 5 0.7 6.8 3.4 354 7 6 165 -7.1 0 -6.8 -7.2 01/04/2007 18:00:00 5.1 0.6 7.2 3.8 4.2 0.9 6.1 1.9 5.3 0.7 7.6 3.8 349 10 7 165 -6.9 0 -6.8 -7.2 01/04/2007 18:10:00 4.9 0.6 6.8 3.8 4.6 0.6 7.2 3.4 4.9 0.7 6.8 3.4 331 13 353 165 -7.4 0.2 -6.8 -7.6 01/04/2007 18:20:00 4.8 0.4 6.1 3.8 4.6 0.5 6.1 3.4 4.8 0.4 6.1 3.4 333 9 346 165 -7.8 0 -7.6 -8.1 01/04/2007 18:30:00 4.4 0.5 6.1 3 4.4 0.5 5.7 2.3 4.5 0.5 5.7 3.4 339 7 330 165 -7.9 0 -7.6 -8.1 01/04/2007 18:40:00 4.4 0.6 6.1 2.6 4.2 0.8 6.1 1.9 4.4 0.5 6.1 2.6 342 9 343 165 -8 0 -7.6 -8.1 01/04/2007 18:50:00 3.9 0.6 5.3 2.3 3.7 0.6 5.3 1.9 3.9 0.6 5.3 2.3 331 15 337 165 -8 0 -7.6 -8.1 01/04/2007 19:00:00 3.8 0.6 5.3 2.3 3.8 0.6 5.3 2.3 3.4 0.6 4.9 1.9 305 11 290 165 -8.1 0.1 -7.9 -8.3 01/04/2007 19:10:00 5.6 0.9 7.6 3.4 5.6 0.9 7.6 3.4 5.2 1.1 8 3 289 9 284 165 -8 0.1 -7.6 -8.1 01/04/2007 19:20:00 5.8 0.5 7.2 4.6 5.9 0.5 7.2 4.6 5 0.8 7.2 3.4 292 5 279 165 -8.1 0 -8.1 -8.3 01/04/2007 19:30:00 5.5 0.6 7.2 4.2 5.5 0.6 6.8 4.2 4.5 0.7 6.8 3 295 7 290 165 -8 0 -7.6 -8.1 01/04/2007 19:40:00 6.2 0.5 7.6 4.9 6.3 0.5 7.6 4.9 5.3 0.9 7.2 3.4 292 6 278 165 -8 0 -7.9 -8.3 01/04/2007 19:50:00 5.3 1.1 8.8 2.6 5.3 1.1 8.8 2.6 4.9 1.2 8.4 3 304 15 282 165 -8 0 -7.6 -8.1 01/04/2007 20:00:00 8.6 1 11.5 6.1 8.6 1 11.5 6.1 7.3 1.1 10.7 4.9 293 7 292 165 -8 0 -7.9 -8.1 01/04/2007 20:10:00 8.1 1.3 11.1 4.6 8 1.3 11.1 3.8 6.6 0.9 9.1 4.2 298 12 297 165 -8 0.1 -7.6 -8.1 01/04/2007 20:20:00 8.3 1.2 10.7 4.9 8.2 1.2 10.3 4.9 6.5 1 9.1 4.2 297 10 316 165 -7.8 0.1 -7.4 -8.1 01/04/2007 20:30:00 9.9 0.9 11.8 6.1 9.9 1 11.8 6.1 8.4 1.1 10.7 5.3 289 6 287 165 -8 0 -7.6 -8.1 01/04/2007 20:40:00 10.5 0.6 11.8 8 10.5 0.6 11.8 8 10.1 0.8 12.6 7.6 284 6 289 165 -7.7 0.1 -7.4 -8.1 01/04/2007 20:50:00 10.2 0.8 11.8 6.8 10.2 0.8 11.8 6.5 8.8 1.4 11.5 4.9 289 7 280 165 -7.5 0 -7.2 -7.6 01/04/2007 21:00:00 9.9 1.3 12.6 6.1 9.8 1.3 12.6 6.1 8.4 1.7 12.2 5.3 295 10 293 165 -7.5 0 -7.2 -7.6 01/04/2007 21:10:00 9 1.2 11.8 6.5 9 1.1 11.5 6.5 7.1 1.3 10.7 3.8 299 9 297 165 -7.5 0.1 -7.2 -7.9 01/04/2007 21:20:00 7.4 1.2 11.1 4.2 7.3 1.2 10.7 4.2 6.3 1.3 11.5 3.4 300 12 287 165 -7.4 0.1 -7.2 -7.6 01/04/2007 21:30:00 7.6 1 10.7 5.3 7.5 1 10.3 5.3 6.1 1 10.3 3.8 301 9 296 165 -7.7 0 -7.4 -8.1 01/04/2007 21:40:00 8.5 0.8 10.7 6.1 8.4 0.8 10.7 6.1 6.2 0.8 8.8 3.8 297 6 291 165 -7.6 0 -7.2 -7.9 01/04/2007 21:50:00 8.2 1.2 11.1 4.9 8.1 1.2 10.7 4.9 6.9 0.9 9.1 4.6 304 9 300 165 -7.2 0.1 -6.8 -7.6 01/04/2007 22:00:00 8.6 1 11.1 6.1 8.5 1 11.1 5.7 7 1 9.5 4.6 300 9 302 165 -7 0 -6.8 -7.2 01/04/2007 22:10:00 9.5 1.3 12.6 6.5 9.3 1.2 11.8 6.1 7.6 1 10.7 4.2 301 9 300 165 -6.9 0 -6.8 -7 01/04/2007 22:20:00 10.8 0.8 12.6 8.4 10.6 0.8 12.2 8 8.1 0.9 10.7 5.7 298 6 308 165 -6.9 0 -6.8 -7.2 01/04/2007 22:30:00 10.7 0.8 13 8.4 10.6 0.7 12.6 8.4 8.3 1 10.7 6.1 300 7 296 165 -6.7 0 -6.6 -7 01/04/2007 22:40:00 9.1 1.1 11.8 4.9 8.9 1.1 11.5 4.9 7.4 1.1 10.3 4.2 300 10 300 165 -6.7 0 -6.4 -6.8 01/04/2007 22:50:00 8.6 1.3 11.5 5.3 8.5 1.3 11.1 5.3 7 1.3 10.3 2.6 302 11 313 165 -6.8 0 -6.6 -6.8 01/04/2007 23:00:00 9.3 1.2 11.8 5.3 9.3 1.2 11.8 6.1 7.4 1.3 10.7 4.2 301 9 303 165 -6.8 0 -6.6 -6.8 01/04/2007 23:10:00 10.6 0.9 12.6 8 10.5 0.8 12.6 8 8.9 1 11.1 5.7 305 7 307 165 -6.6 0.1 -6.4 -6.8 01/04/2007 23:20:00 11.1 0.8 13 9.1 11 0.8 12.6 9.1 8.7 1 11.5 6.1 305 6 305 165 -6.5 0 -6.4 -6.6 01/04/2007 23:30:00 10.8 0.8 13 8.4 10.7 0.8 13 8.4 8 1 10.7 5.7 302 6 301 165 -6.6 0 -6.4 -6.8 01/04/2007 23:40:00 9.5 0.8 11.1 7.2 9.4 0.8 11.1 7.2 7 0.7 9.1 4.9 301 5 301 165 -6.6 0 -6.6 -6.8 01/04/2007 23:50:00 8.5 0.8 10.3 6.5 8.4 0.8 10.7 6.5 6.6 0.8 8.4 4.2 301 6 308 165 -6.7 0 -6.6 -6.8 01/05/2007 00:00:00 9.1 0.8 11.5 7.2 9 0.8 11.1 7.2 6.6 0.8 9.5 4.6 298 6 293 165 -6.7 0 -6.6 -6.8 01/05/2007 00:10:00 9 0.7 11.1 7.2 8.9 0.7 10.7 7.2 6.8 0.7 8.8 5.3 301 7 299 165 -6.8 0 -6.6 -7 01/05/2007 00:20:00 8.7 0.7 10.3 7.2 8.6 0.7 10.3 6.8 6.7 0.8 9.1 4.9 300 6 304 165 -6.7 0 -6.6 -6.8 01/05/2007 00:30:00 9.2 0.8 11.1 6.8 9.1 0.8 11.1 7.2 6.7 0.9 10.3 4.9 298 6 301 165 -6.7 0 -6.6 -6.8 01/05/2007 00:40:00 9.7 0.6 11.1 7.6 9.7 0.6 11.1 7.2 7.1 0.8 9.1 4.9 299 6 308 165 -6.6 0 -6.4 -6.8 01/05/2007 00:50:00 9.1 0.5 10.3 7.6 9.1 0.6 10.3 7.2 6.6 0.7 8.4 4.6 298 6 300 165 -6.6 0 -6.4 -6.8 01/05/2007 01:00:00 7.8 0.6 9.1 5.3 7.7 0.6 9.1 5.3 6.8 0.8 8.4 4.9 307 6 301 165 -6.6 0 -6.4 -6.8 01/05/2007 01:10:00 8 0.8 9.9 6.5 7.9 0.8 9.5 6.1 6.4 1 9.1 4.2 303 5 302 165 -6.6 0 -6.4 -6.8 01/05/2007 01:20:00 6.8 0.7 8.4 4.9 6.7 0.7 8.4 4.9 5.6 0.9 8 3.4 305 8 304 165 -6.5 0 -6.4 -6.8 01/05/2007 01:30:00 4.7 0.8 6.5 3 4.6 0.8 6.5 3 3.9 0.7 6.1 2.3 303 8 302 165 -6.5 0 -6.4 -6.8 01/05/2007 01:40:00 3.9 0.7 6.5 1.9 3.6 1 6.1 0.4 3.9 0.8 6.5 2.3 334 14 326 165 -6.5 0 -6.4 -6.8 01/05/2007 01:50:00 2.1 1.1 4.2 0.4 2 1.2 4.2 0.4 2.5 1 4.2 0.4 347 22 320 165 -6.6 0 -6.4 -6.8 01/05/2007 02:00:00 1 0.7 3.8 0.4 1 0.7 3.8 0.4 1.4 0.8 3.4 0.4 192 117 247 165 -6.7 0 -6.4 -6.8 01/05/2007 02:10:00 2.1 1 4.6 0.4 2.3 1 4.9 0.4 2.4 1 4.6 0.7 230 22 248 165 -6.5 0 -6.1 -6.6 01/05/2007 02:20:00 1.3 0.8 4.2 0.4 1.5 0.9 4.6 0.4 1.5 1 4.2 0.4 263 32 269 165 -6.7 0 -6.4 -6.8 01/05/2007 02:30:00 0.5 0.3 1.5 0.4 0.5 0.3 1.5 0.4 0.7 0.5 1.9 0.4 246 12 248 165 -6.9 0.1 -6.6 -7.2 01/05/2007 02:40:00 0.8 0.5 2.3 0.4 0.7 0.4 1.9 0.4 0.9 0.5 2.3 0.4 293 49 358 165 -7.1 0 -6.8 -7.2 01/05/2007 02:50:00 1.7 0.9 4.2 0.4 1.6 0.9 4.2 0.4 1.8 0.8 4.6 0.4 322 17 311 165 -7.4 0.1 -7 -7.6 01/05/2007 03:00:00 3.1 1.2 4.9 0.4 3.3 1.2 5.3 0.4 2.7 1.3 4.9 0.4 292 18 286 165 -7.2 0 -6.8 -7.4 01/05/2007 03:10:00 4.2 1.3 8.4 1.9 4.2 1.2 8.4 2.3 3.4 1.1 6.5 1.1 292 9 292 165 -7.3 0 -7 -7.4 01/05/2007 03:20:00 5.9 1.1 9.5 3.4 6 1 9.1 3.8 4.9 1 8.4 3 290 9 289 165 -6.9 0.1 -6.6 -7.4 01/05/2007 03:30:00 6.7 1.1 9.5 4.2 6.6 1.1 9.5 4.2 5.5 1.2 9.1 3 300 13 300 165 -6.7 0 -6.6 -7 01/05/2007 03:40:00 5.9 1.1 9.1 3 5.8 1.1 8.8 2.6 5 1 8 2.3 305 11 284 165 -6.9 0 -6.6 -7 01/05/2007 03:50:00 5 0.9 7.2 3 4.9 0.9 7.2 2.6 4 1 6.8 1.9 295 11 307 165 -7 0 -6.8 -7.2 01/05/2007 04:00:00 4.9 0.9 6.8 2.3 4.9 0.8 6.8 2.3 4.2 0.9 6.5 2.3 285 10 290 165 -7.1 0 -6.8 -7.4 01/05/2007 04:10:00 2.4 1 4.9 0.4 2.6 1 5.3 0.4 2.2 0.8 4.2 0.7 265 20 275 165 -7.3 0 -7.2 -7.6 01/05/2007 04:20:00 4 0.8 6.5 2.3 4.1 0.7 6.1 2.3 3.6 0.7 5.7 1.9 279 8 289 165 -6.9 0.1 -6.8 -7.4 01/05/2007 04:30:00 5 0.8 7.2 3.4 5 0.8 7.2 3 4.4 0.9 6.8 2.3 287 5 286 165 -6.7 0.1 -6.4 -6.8 01/05/2007 04:40:00 5.6 0.5 7.2 4.6 5.5 0.5 6.8 4.6 4.4 0.7 6.5 3 300 6 297 165 -6.6 0 -6.4 -6.8 01/05/2007 04:50:00 6.2 0.5 7.6 4.9 6 0.5 7.6 4.6 5.6 0.6 7.2 4.2 310 4 314 165 -6.7 0.1 -6.4 -7 01/05/2007 05:00:00 5.7 0.6 7.6 3.8 5.6 0.6 7.6 3.8 4.5 0.7 6.5 3 303 6 305 165 -6.5 0 -6.4 -6.8 01/05/2007 05:10:00 5.6 0.4 6.8 4.6 5.5 0.4 6.8 4.6 4.3 0.5 5.7 3.4 304 3 303 165 -6.6 0 -6.4 -6.8 01/05/2007 05:20:00 5.6 0.4 6.5 4.6 5.5 0.4 6.5 4.6 4.7 0.5 6.1 3.4 307 3 307 165 -6.8 0.1 -6.6 -7 01/05/2007 05:30:00 5.9 0.4 6.8 4.9 5.8 0.4 6.8 4.6 5.1 0.5 6.5 3.4 307 3 306 165 -6.8 0 -6.6 -6.8 01/05/2007 05:40:00 5.9 0.4 6.8 4.9 5.7 0.4 6.8 4.9 4.8 0.6 6.5 3 305 5 307 165 -6.8 0 -6.6 -7 01/05/2007 05:50:00 5.4 0.5 6.8 4.2 5.4 0.5 6.8 4.2 4.2 0.7 6.8 2.6 299 8 288 165 -6.9 0 -6.6 -7 01/05/2007 06:00:00 5.6 0.5 6.5 4.6 5.5 0.5 6.5 4.6 4.4 0.8 6.5 3 294 5 287 165 -6.7 0.1 -6.4 -6.8 01/05/2007 06:10:00 5.9 0.4 6.8 4.9 5.9 0.4 6.8 4.9 4.1 0.4 5.3 3 300 4 295 165 -6.7 0 -6.4 -6.8 01/05/2007 06:20:00 6.6 0.5 8 4.9 6.5 0.5 7.6 4.9 4.5 0.5 6.1 3.4 298 4 302 165 -6.6 0 -6.6 -6.8 01/05/2007 06:30:00 6.6 0.7 8.8 5.3 6.6 0.7 8.8 5.3 5.3 0.8 7.6 3.4 292 5 297 165 -6.4 0.1 -6.1 -6.8 01/05/2007 06:40:00 6.8 0.7 8.4 5.3 6.8 0.7 8.4 5.3 6 0.9 8 3.8 289 5 289 165 -6.3 0 -6.1 -6.6 01/05/2007 06:50:00 6.8 0.6 8 5.3 6.8 0.6 8 4.9 5.9 1 8 3.4 288 6 293 165 -6.2 0 -5.9 -6.4 01/05/2007 07:00:00 7 0.5 8.4 5.7 7 0.5 8.4 5.7 6.3 0.8 8.8 4.2 288 4 282 165 -6 0 -5.7 -6.4 01/05/2007 07:10:00 7.2 0.6 8.8 6.1 7.2 0.6 8.8 5.7 5.8 0.7 7.6 4.2 291 4 293 165 -6.1 0 -5.7 -6.4 01/05/2007 07:20:00 7.6 0.5 9.5 6.1 7.6 0.5 9.5 5.7 6.6 0.9 8.4 4.6 289 4 286 165 -5.9 0 -5.7 -6.1 01/05/2007 07:30:00 8.1 0.7 9.9 6.5 8.1 0.7 10.3 6.5 7 1 9.9 4.6 287 6 287 165 -5.8 0.1 -5.5 -6.1 01/05/2007 07:40:00 7.2 0.7 8.8 5.3 7.2 0.7 8.8 4.9 6.3 1 8.4 4.2 288 6 288 165 -5.8 0 -5.5 -5.9 01/05/2007 07:50:00 6.6 0.6 8.4 4.9 6.5 0.6 8.4 4.6 5.2 0.8 7.6 3.4 292 5 291 165 -5.9 0 -5.7 -6.1 01/05/2007 08:00:00 6.8 1 8.8 3.8 6.7 1 8.8 4.2 5.8 1.2 8.8 2.6 288 8 288 165 -5.8 0 -5.5 -6.1 01/05/2007 08:10:00 6.5 1 8.8 4.6 6.4 1 8.4 4.2 5.3 1.2 8.4 3 292 9 292 165 -5.8 0 -5.5 -6.1 01/05/2007 08:20:00 6.3 1 8.4 3 6.2 1 8.8 3 5.3 0.9 7.6 2.6 301 10 287 165 -5.6 0 -5.5 -5.7 01/05/2007 08:30:00 5 1 8 3 5 1 8 3 4.3 0.8 7.2 2.6 305 11 294 165 -5.9 0 -5.5 -6.1 01/05/2007 08:40:00 5.4 1 8 2.6 5.3 1 8 2.6 5 0.9 7.6 3 312 8 312 165 -6.1 0 -5.9 -6.4 01/05/2007 08:50:00 5.4 1 8 3.4 5.3 1 8 3.4 4.7 1.1 8.4 2.6 309 11 308 165 -6.2 0.1 -6.1 -6.4 01/05/2007 09:00:00 4.9 1.1 8.4 1.9 4.8 1.1 8 2.3 4.2 1 7.2 2.3 305 15 321 165 -6.1 0 -5.9 -6.4 01/05/2007 09:10:00 5.2 1.2 8.4 2.3 5.1 1.2 8.4 1.9 4.4 1.1 8 1.9 306 12 304 165 -6.3 0.1 -6.1 -6.6 01/05/2007 09:20:00 5.9 1 8.4 3.8 5.8 1 8.8 3.4 4.9 1.2 8.4 2.6 303 10 322 165 -6.3 0.1 -5.9 -6.6 01/05/2007 09:30:00 5.7 0.9 8.4 4.2 5.6 0.8 8.4 3.8 4.7 1 8 2.6 296 8 297 165 -6.5 0 -6.1 -6.8 01/05/2007 09:40:00 6.8 0.8 8.8 5.3 6.7 0.8 9.1 4.9 5.6 1 8.8 3.4 302 9 313 165 -6.8 0.1 -6.6 -7 01/05/2007 09:50:00 7.6 0.8 9.5 4.9 7.5 0.8 9.5 5.3 6.3 1.1 9.9 3.8 302 10 312 165 -6.7 0 -6.6 -6.8 01/05/2007 10:00:00 7.7 0.8 10.3 6.1 7.7 0.8 9.9 6.1 6.1 1 9.1 3.8 301 9 313 165 -6.8 0.1 -6.6 -7 01/05/2007 10:10:00 7.6 0.8 9.5 5.3 7.5 0.8 9.5 5.3 5.9 0.8 8 3.4 299 7 304 165 -6.8 0 -6.6 -7 01/05/2007 10:20:00 7.8 0.8 9.9 6.1 7.7 0.8 9.9 6.1 6.1 1 8.8 4.2 299 10 309 165 -6.5 0 -6.4 -6.8 01/05/2007 10:30:00 8.7 0.8 11.1 5.3 8.6 0.8 10.7 5.7 6.6 0.8 9.5 4.9 300 9 303 165 -6.4 0 -6.1 -6.6 01/05/2007 10:40:00 8.6 0.9 10.3 6.1 8.5 0.9 10.3 5.7 6.5 0.7 8.4 4.6 300 9 301 165 -6.4 0 -6.4 -6.6 01/05/2007 10:50:00 8.4 0.7 10.7 6.8 8.3 0.7 10.3 6.8 6.7 1.1 9.5 4.6 305 6 310 165 -6.4 0 -6.1 -6.6 01/05/2007 11:00:00 8.4 0.7 9.9 6.5 8.4 0.7 10.3 6.5 6.6 1 9.1 4.9 302 7 307 165 -6.4 0 -6.1 -6.6 01/05/2007 11:10:00 9.1 0.9 11.1 6.8 9 0.9 11.1 7.2 7.5 1.1 10.7 4.9 303 8 307 165 -6.4 0 -6.1 -6.6 01/05/2007 11:20:00 9.3 0.9 11.8 7.2 9.2 0.9 11.5 7.2 7.6 1 10.7 5.7 303 10 295 165 -6.3 0 -6.1 -6.6 01/05/2007 11:30:00 9.4 0.8 11.5 7.6 9.4 0.8 11.5 7.2 7.7 1 10.3 4.9 303 10 301 165 -6.4 0 -6.1 -6.6 01/05/2007 11:40:00 9.4 0.8 11.5 6.5 9.3 0.8 11.5 6.5 7.5 1 10.3 5.3 303 8 302 165 -6.4 0 -6.1 -6.6 01/05/2007 11:50:00 8.6 0.9 10.7 6.1 8.5 0.9 11.1 6.1 7.3 1 9.9 5.7 303 10 309 165 -6.3 0 -6.1 -6.6 01/05/2007 12:00:00 8.4 0.8 10.7 6.5 8.3 0.8 10.7 6.1 7.1 0.9 9.9 4.9 306 8 295 165 -6.2 0 -6.1 -6.6 01/05/2007 12:10:00 8 1.2 11.1 5.3 7.9 1.1 10.7 5.3 7.4 1.3 10.3 4.6 317 12 306 165 -5.8 0.2 -5.5 -6.4 01/05/2007 12:20:00 6.9 1.3 10.7 2.6 6.9 1.2 10.3 3 6.4 1.3 10.3 3.8 316 12 313 165 -5.7 0.1 -5.5 -5.9 01/05/2007 12:30:00 7.5 1.1 10.3 4.2 7.5 1.1 10.3 4.6 6.9 1.1 9.9 4.6 313 11 302 165 -5.9 0 -5.7 -6.1 01/05/2007 12:40:00 7.9 1.1 11.5 5.3 7.8 1.1 10.7 5.3 7.3 1.3 10.7 4.6 315 10 320 165 -5.8 0 -5.5 -6.1 01/05/2007 12:50:00 8.8 1.2 11.8 4.9 8.7 1.2 11.5 4.6 8.1 1.4 11.5 4.6 312 10 315 165 -5.9 0 -5.7 -6.1 01/05/2007 13:00:00 6.8 1.5 11.8 3.8 6.8 1.5 11.1 3.8 6.4 1.6 11.5 3 315 13 325 165 -5.7 0.1 -5.3 -5.9 01/05/2007 13:10:00 4 1 7.2 0.7 4 1 6.5 0.7 3.7 1 6.5 0.7 302 17 301 165 -5.4 0.2 -4.8 -5.7 01/05/2007 13:20:00 3.1 1 6.1 1.5 2.9 0.7 5.3 1.5 3 1 6.8 1.1 317 27 3 165 -5.2 0.1 -4.8 -5.7 01/05/2007 13:30:00 3.7 1.2 6.8 2.3 3.6 1.2 7.2 1.9 3.8 1.2 6.8 2.3 331 11 343 165 -4.8 0.3 -4.4 -5.5 01/05/2007 13:40:00 7.1 1 9.5 4.6 6.9 1.1 9.5 3.8 7 1 9.5 4.2 334 15 334 165 -5.6 0.2 -5.3 -6.1 01/05/2007 13:50:00 6.7 0.9 8.8 4.6 6.7 0.8 8.8 4.6 6.4 1.1 9.5 3.8 312 16 328 165 -6.1 0.1 -5.7 -6.4 01/05/2007 14:00:00 5.7 0.8 8 3.4 5.7 0.8 8 3.4 4.8 0.8 7.2 3.4 299 12 290 165 -6.1 0.1 -5.7 -6.4 01/05/2007 14:10:00 7.2 1.1 9.9 4.9 7.2 1 9.9 4.9 6.4 1.2 9.5 3.8 301 12 299 165 -6.5 0 -6.1 -6.8 01/05/2007 14:20:00 6.9 1.2 9.5 3.4 6.9 1.2 9.5 3.4 5.9 1 8.4 2.6 307 9 309 165 -6.4 0.1 -6.1 -6.8 01/05/2007 14:30:00 5.1 1.2 8.4 2.3 5.1 1.2 8 2.3 4.4 1.2 7.2 2.6 297 13 292 165 -6.2 0.2 -5.7 -6.6 01/05/2007 14:40:00 4.6 1.3 8 2.3 4.5 1.3 8 2.3 4.2 1.1 8.4 1.5 310 14 295 165 -5.9 0.2 -5.5 -6.4 01/05/2007 14:50:00 4.9 1 8 2.6 4.9 1.1 7.6 2.6 4.1 1.2 8.8 2.3 296 10 284 165 -6.4 0.2 -5.7 -6.8 01/05/2007 15:00:00 4.4 1 6.8 2.3 4.5 1 7.2 2.3 4.1 1.2 7.6 1.9 290 15 281 165 -6.6 0 -6.4 -6.8 01/05/2007 15:10:00 6.4 1.6 9.9 3 6.4 1.6 9.5 3.4 5.9 1.4 8.8 3.4 310 11 295 165 -6.6 0 -6.4 -6.8 01/05/2007 15:20:00 5.6 1.6 9.1 2.6 5.6 1.6 9.1 3 4.8 1.6 8.8 2.3 293 9 300 165 -7 0.2 -6.4 -7.4 01/05/2007 15:30:00 6.5 1 8.4 4.6 6.6 1 8.8 4.6 5.5 1 8.4 3 301 11 293 165 -7.2 0.2 -6.8 -7.6 01/05/2007 15:40:00 8.5 1.1 10.7 5.3 8.4 1.1 10.7 5.7 7.1 1.3 9.9 4.2 304 7 297 165 -7.8 0.1 -7.4 -8.1 01/05/2007 15:50:00 8.4 1.1 11.8 5.7 8.3 1.1 11.8 5.7 7.1 1.1 11.5 4.2 305 8 292 165 -8.1 0 -7.9 -8.3 01/05/2007 16:00:00 8 1.2 10.7 5.3 8 1.2 11.1 5.7 6.7 1.1 9.9 4.2 305 11 290 165 -8.1 0.1 -7.9 -8.3 01/05/2007 16:10:00 8.2 1 11.8 6.1 8.2 1 11.5 6.1 6.4 1.2 11.1 3.8 295 9 282 165 -8 0 -7.9 -8.3 01/05/2007 16:20:00 8.5 0.9 11.1 5.7 8.5 0.9 11.1 5.7 6.4 0.9 9.1 4.6 297 8 312 165 -8.3 0 -8.1 -8.5 01/05/2007 16:30:00 8.3 1.1 12.2 5.3 8.3 1.1 11.8 5.3 6.8 1.2 11.1 4.2 303 11 271 165 -8.4 0 -8.1 -8.5 01/05/2007 16:40:00 8.9 0.9 11.1 6.5 8.9 0.9 11.1 6.1 7.8 1.2 11.1 4.9 307 10 296 165 -8.4 0 -8.3 -8.5 01/05/2007 16:50:00 9.5 1.1 12.2 6.8 9.4 1.1 11.8 6.8 8.9 1.1 11.8 5.7 312 8 303 165 -8.5 0.1 -8.3 -8.7 01/05/2007 17:00:00 8.6 1 10.7 6.1 8.6 1 10.7 6.5 7.4 1.4 10.7 4.2 297 14 281 165 -8.6 0 -8.3 -8.9 01/05/2007 17:10:00 7.3 1.1 10.7 4.6 7.3 1.1 10.7 5.3 6.5 1.3 9.5 3.4 298 17 287 165 -8.5 0.1 -8.3 -8.7 01/05/2007 17:20:00 8.3 0.6 9.9 6.5 8.2 0.6 9.9 6.8 7 1 9.5 4.6 304 9 289 165 -8.7 0 -8.5 -8.9 01/05/2007 17:30:00 8.4 0.6 9.9 6.8 8.3 0.6 9.9 6.8 7 0.7 9.1 4.6 306 4 307 165 -8.9 0 -8.7 -9.1 01/05/2007 17:40:00 6.3 1 9.1 4.9 6.3 0.9 8.8 4.6 5.6 0.9 8 3 296 12 302 165 -9.2 0.1 -8.9 -9.7 01/05/2007 17:50:00 5.1 0.7 7.2 3.4 5.3 0.8 7.2 3.4 5.2 0.8 7.2 3.4 278 6 279 165 -9.6 0 -9.3 -9.7 01/05/2007 18:00:00 6.3 0.6 8 4.9 6.3 0.6 8 4.9 5.5 1.2 8 3.4 289 8 282 165 -9.8 0.1 -9.5 -10.2 01/05/2007 18:10:00 6.3 0.5 7.6 5.3 6.4 0.4 7.6 5.3 5.1 0.7 6.8 3.8 299 7 307 165 -9.9 0.2 -9.3 -10.4 01/05/2007 18:20:00 5.6 0.6 7.6 4.2 5.6 0.6 8 4.6 4.8 0.8 7.2 3.4 300 12 307 165 -9.4 0 -9.1 -9.7 01/05/2007 18:30:00 5.3 0.4 6.5 4.2 5.3 0.4 6.5 4.6 4.3 0.6 5.7 3 305 7 309 165 -9.4 0.1 -9.3 -9.7 01/05/2007 18:40:00 6.2 0.5 7.2 4.9 6.2 0.5 7.2 5.3 5.3 0.9 6.8 3.4 308 5 309 165 -9.7 0.2 -9.3 -10.2 01/05/2007 18:50:00 6.1 0.5 7.2 4.6 6.1 0.5 7.2 4.6 5.2 1.1 7.2 3 307 7 312 165 -10.3 0 -10 -10.6 01/05/2007 19:00:00 6 0.8 8.4 3.8 6 0.7 8 4.2 4.8 1 7.6 3 302 7 310 165 -10.2 0.1 -10 -10.8 01/05/2007 19:10:00 6.8 0.7 9.1 4.6 6.8 0.7 9.1 4.6 5.9 1 8.4 3.4 306 11 295 165 -10 0 -9.7 -10.4 01/05/2007 19:20:00 7.2 0.7 8.8 4.9 7.2 0.7 8.8 4.9 5.7 0.8 7.6 4.2 299 9 297 165 -10.1 0.1 -9.7 -10.2 01/05/2007 19:30:00 7.2 0.5 8.8 5.7 7.2 0.5 8.4 5.7 5.4 0.7 7.2 3.8 294 6 303 165 -10.4 0 -10.2 -10.6 01/05/2007 19:40:00 6.5 0.6 9.1 5.3 6.5 0.6 9.1 5.3 5.3 0.8 8.4 3.4 295 8 307 165 -10.5 0.2 -10.2 -10.8 01/05/2007 19:50:00 7.5 0.5 9.1 6.5 7.5 0.5 9.1 6.5 5.5 0.7 7.6 4.2 299 5 293 165 -10.5 0.2 -10.2 -11 01/05/2007 20:00:00 7.4 0.8 9.5 5.3 7.3 0.8 9.1 5.7 6.1 1.5 9.1 3.8 292 7 294 165 -10.9 0 -10.8 -11 01/05/2007 20:10:00 10 1.1 13.3 7.6 10.1 1.1 13.7 8.4 8.8 1.6 13.3 5.7 287 8 278 165 -10.9 0 -10.6 -11 01/05/2007 20:20:00 11.5 1.1 14.5 7.2 11.5 1.1 14.5 7.6 9.6 1.5 13.7 6.1 290 9 290 165 -10.5 0.1 -10.2 -10.8 01/05/2007 20:30:00 10.4 1.1 13 7.2 10.3 1.2 13 7.2 8.3 1.1 11.8 6.1 302 9 298 165 -10.9 0 -10.6 -11.2 01/05/2007 20:40:00 10.2 1.3 14.1 7.2 10 1.3 13.3 6.8 8.4 1.2 13.3 5.3 303 9 301 165 -11 0 -11 -11.4 01/05/2007 20:50:00 12.6 1 14.5 9.1 12.4 1 14.5 9.5 10.7 1.5 14.1 7.2 306 7 301 165 -10.9 0 -10.8 -11.4 01/05/2007 21:00:00 12.5 1 14.5 9.5 12.4 1.1 14.5 9.5 10.5 1.1 13 6.8 305 8 300 165 -11.1 0.1 -10.8 -11.4 01/05/2007 21:10:00 12.8 1.5 15.3 8.8 12.7 1.4 15.3 9.1 9.3 1.2 12.6 6.5 295 9 283 165 -11.4 0 -11.2 -11.6 01/05/2007 21:20:00 12.5 1 14.9 9.9 12.4 1 14.5 10.3 8.9 1.1 11.8 6.5 293 9 285 165 -11.4 0.1 -11 -11.8 01/05/2007 21:30:00 10.9 0.9 13.3 8.4 10.9 0.9 13.3 8.4 8.9 1.3 11.8 6.5 305 9 302 165 -11.6 0 -11.4 -11.8 01/05/2007 21:40:00 8.7 0.9 11.1 6.5 8.6 0.9 11.1 6.5 7.9 1 10.3 5.3 309 8 314 165 -11.6 0 -11.4 -11.8 01/05/2007 21:50:00 7.7 0.7 10.3 6.1 7.6 0.7 9.9 6.1 7.4 1 9.9 4.9 313 7 305 165 -11.6 0 -11.4 -11.8 01/05/2007 22:00:00 7.4 1.1 10.3 5.3 7.3 1.1 9.9 4.9 7 1 9.5 4.6 311 9 282 165 -11.6 0 -11.4 -11.8 01/05/2007 22:10:00 5.4 1 8.8 3 5.4 1 8.8 3 4.8 1 7.2 2.6 302 12 305 165 -11.8 0 -11.6 -11.8 01/05/2007 22:20:00 5.6 1 8.4 3 5.6 1 8.4 3 4.9 1.2 8.4 2.6 302 12 309 165 -11.8 0 -11.6 -12 01/05/2007 22:30:00 6.2 1 9.1 3.8 6.1 1 9.1 3.8 5.4 1.2 8.4 3 301 16 292 165 -11.8 0 -11.6 -12.2 01/05/2007 22:40:00 5.1 0.9 7.6 2.6 5 0.9 7.2 2.3 4.5 1 7.2 2.3 296 16 327 165 -11.7 0 -11.6 -11.8 01/05/2007 22:50:00 5.1 1.9 10.3 1.9 5.2 1.7 10.7 2.3 4.8 1.5 9.5 1.5 293 22 302 165 -11.5 0.1 -11.4 -11.8 01/05/2007 23:00:00 3.8 1.7 10.7 0.4 4 1.7 10.7 0.4 3.9 1.6 8.4 0.7 260 32 313 165 -11.7 0.1 -11.4 -12 01/05/2007 23:10:00 2 1.4 5.7 0.4 2.1 1.5 6.5 0.4 2.1 1.5 5.7 0.4 254 58 272 165 -11.9 0.2 -11.4 -12.2 01/05/2007 23:20:00 2.3 1.3 6.5 0.4 2.3 1.4 6.8 0.4 2.2 1.2 6.1 0.4 217 47 305 165 -12 0.2 -11.6 -12.2 01/05/2007 23:30:00 5.6 2.9 11.8 0.4 5.8 3.1 11.8 0.4 5 2.8 12.2 0.4 268 29 282 165 -11.7 0.2 -11 -11.8 01/05/2007 23:40:00 10.4 1.7 14.5 6.1 10.3 1.7 13.7 6.1 9.4 1.9 14.1 5.3 281 9 290 165 -10.8 0.2 -10.2 -11.4 01/05/2007 23:50:00 13.3 1.5 17.6 9.1 13.1 1.6 17.6 9.1 10.9 1.8 17.6 6.8 286 10 245 165 -10.3 0.1 -10 -10.8 01/06/2007 00:00:00 14.4 1.7 17.6 9.5 14.3 1.7 17.6 9.9 11.8 2.1 16.8 7.2 284 12 289 165 -10.3 0 -10.2 -10.6 01/06/2007 00:10:00 14.9 1.2 17.9 11.1 14.7 1.2 17.9 10.7 11.8 1.5 16.4 8.8 287 11 290 165 -10.4 0 -10.2 -10.6 01/06/2007 00:20:00 14.5 1.3 18.7 11.5 14.3 1.3 17.9 11.1 11.1 1.5 16.1 7.6 292 13 298 165 -10.5 0 -10.4 -10.8 01/06/2007 00:30:00 14.5 1.2 17.2 11.1 14.3 1.2 16.8 11.1 10.9 1.3 16.1 8 291 12 297 165 -10.5 0 -10.4 -10.8 01/06/2007 00:40:00 12.2 1.5 16.4 8.8 12.1 1.5 16.8 8.4 9.4 1.3 13.3 5.7 297 11 295 165 -10.4 0 -10.2 -10.6 01/06/2007 00:50:00 9.7 0.8 12.2 7.6 9.5 0.8 11.8 7.6 9.2 0.9 11.5 5.3 313 7 309 165 -10.8 0.1 -10.6 -11 01/06/2007 01:00:00 9.3 1 12.2 7.6 9.1 1 11.8 7.2 9.1 0.9 11.1 6.8 315 7 308 165 -10.9 0 -10.6 -11 01/06/2007 01:10:00 10 1.5 13.3 6.8 9.8 1.4 13.3 6.8 9.4 1.4 13.3 6.1 312 8 312 165 -10.9 0 -10.8 -11 01/06/2007 01:20:00 9.8 1.2 14.1 7.2 9.7 1.2 13.7 7.2 9 1.4 13 5.3 309 12 318 165 -10.7 0 -10.6 -11 01/06/2007 01:30:00 10.2 1.6 14.1 6.1 10.1 1.5 13.3 6.1 9.2 1.7 12.6 5.3 302 15 295 165 -10.4 0 -10.2 -10.8 01/06/2007 01:40:00 9.9 1.5 14.1 5.7 9.8 1.5 13.7 5.7 8.6 1.6 13 4.9 305 12 314 165 -10.3 0 -10.2 -10.6 01/06/2007 01:50:00 7.6 1.7 12.2 3 7.6 1.7 12.6 3 6.8 1.6 11.5 2.6 291 14 289 165 -10.2 0 -10 -10.6 01/06/2007 02:00:00 7.4 1.5 11.5 4.2 7.5 1.5 11.5 4.9 6.9 1.3 12.2 3.8 284 13 286 165 -10.4 0 -10.2 -10.6 01/06/2007 02:10:00 8 1.7 11.8 3 8.1 1.7 12.2 3.4 7 1.7 11.8 3 288 15 328 165 -10.4 0 -10.2 -10.6 01/06/2007 02:20:00 7.6 1.6 11.8 4.6 7.6 1.6 11.8 4.2 6.6 1.7 11.8 3.4 289 10 290 165 -10.5 0 -10.4 -10.8 01/06/2007 02:30:00 7.7 1.3 12.2 4.9 7.7 1.3 12.6 4.9 6.6 1.5 11.1 4.2 292 13 308 165 -10.5 0 -10.4 -10.6 01/06/2007 02:40:00 11.2 2 14.9 6.1 11.2 1.9 14.9 6.5 9.3 1.9 14.9 4.9 289 9 292 165 -10.3 0.1 -10 -10.6 01/06/2007 02:50:00 12.3 1.2 15.6 9.5 12.2 1.2 15.6 9.5 10.4 1.5 15.3 6.5 287 11 296 165 -10 0 -9.7 -10.2 01/06/2007 03:00:00 9 1.4 11.8 4.9 9.4 1.2 11.8 6.5 8.9 1.3 12.2 6.1 277 8 279 165 -10 0 -9.7 -10.2 01/06/2007 03:10:00 5.8 0.8 7.6 3.4 6.5 1 9.1 4.2 6.2 1 8.8 4.2 275 9 268 165 -10.2 0 -10 -10.4 01/06/2007 03:20:00 4.7 0.6 6.1 3 4.9 0.6 6.1 3.4 4.6 0.7 6.1 3 272 10 280 165 -10.3 0 -10.2 -10.6 01/06/2007 03:30:00 6.1 1.1 8.4 3.4 7.1 0.9 9.5 4.9 6.8 0.8 8.8 4.9 258 7 254 165 -9.8 0.2 -9.5 -10.4 01/06/2007 03:40:00 6.5 1.1 8.8 3.8 7.3 0.9 9.5 5.3 7.1 0.9 9.5 4.9 266 8 256 165 -9.5 0.1 -9.3 -9.7 01/06/2007 03:50:00 6.8 1.2 9.9 3.8 7.5 1 10.3 4.9 7.3 1 9.9 4.9 265 8 265 165 -9.3 0.2 -8.9 -10 01/06/2007 04:00:00 6.1 1 8.4 3.4 6.6 0.8 8.4 4.2 6.4 0.9 9.1 4.2 256 11 250 165 -9.1 0.1 -8.9 -9.5 01/06/2007 04:10:00 5.5 1.2 8 2.6 6.2 0.8 8.4 4.6 6.1 0.8 8.4 4.6 264 13 277 165 -9.1 0 -8.9 -9.3 01/06/2007 04:20:00 5.5 0.9 8.4 3.4 5.5 1 9.5 3.4 5.4 1 8.8 3.4 230 17 258 165 -9.5 0.2 -9.1 -9.7 01/06/2007 04:30:00 6.5 1.7 10.7 2.6 6.7 1.7 11.1 3 6.4 1.5 10.3 2.6 249 20 255 165 -8.9 0.1 -8.5 -9.3 01/06/2007 04:40:00 4.9 0.7 6.5 3.4 4.9 0.7 6.5 3.4 4.7 0.6 6.8 3.4 233 7 236 165 -9.3 0.2 -8.7 -9.7 01/06/2007 04:50:00 4.4 1 8.4 2.3 4.7 0.8 8 3 4.7 0.8 7.2 3 249 13 248 165 -9.4 0 -9.3 -9.7 01/06/2007 05:00:00 3.3 0.7 5.3 1.5 3.3 0.7 4.9 1.9 3.4 0.6 4.6 1.9 234 21 289 165 -9.4 0 -9.1 -9.7 01/06/2007 05:10:00 2.7 0.8 4.9 1.1 2.7 0.8 4.6 1.1 2.9 0.8 5.3 1.9 226 27 212 165 -9.5 0.2 -9.3 -10 01/06/2007 05:20:00 4.1 0.7 5.7 1.9 4.1 0.7 6.1 1.9 4.6 0.7 6.1 2.6 220 7 225 165 -9.8 0 -9.7 -10.2 01/06/2007 05:30:00 4.5 0.6 6.5 2.6 4.5 0.6 6.1 3 4.7 0.6 6.1 3.4 229 12 224 165 -9.7 0 -9.7 -10.2 01/06/2007 05:40:00 3.9 0.4 4.9 2.3 3.9 0.4 4.9 2.3 4.3 0.4 5.3 3 221 6 225 165 -9.6 0 -9.3 -9.7 01/06/2007 05:50:00 4.7 0.6 6.5 3.8 4.7 0.6 6.5 3.4 4.9 0.5 6.1 3.4 216 5 223 165 -9.6 0 -9.3 -9.7 01/06/2007 06:00:00 4.4 0.7 6.1 3 4.4 0.7 6.1 2.6 4.7 0.5 6.1 3.4 232 6 228 165 -9.7 0 -9.3 -10 01/06/2007 06:10:00 2.4 0.9 4.6 0.4 2.5 0.9 4.6 0.4 3 0.9 5.3 0.7 253 18 253 165 -9.5 0 -9.3 -9.7 01/06/2007 06:20:00 0.4 0.2 1.5 0.4 0.4 0.2 1.5 0.4 0.5 0.4 2.3 0.4 310 17 269 165 -9.1 0 -8.9 -9.3 01/06/2007 06:30:00 1.3 0.4 2.3 0.4 1.1 0.4 2.3 0.4 1.4 0.4 2.3 0.4 136 49 114 165 -9.3 0.2 -8.9 -9.7 01/06/2007 06:40:00 0.6 0.4 1.9 0.4 0.5 0.3 1.9 0.4 0.6 0.3 1.5 0.4 219 66 207 165 -9.4 0 -9.1 -9.7 01/06/2007 06:50:00 0.8 0.4 1.9 0.4 0.7 0.4 1.5 0.4 1 0.5 1.9 0.4 189 22 187 165 -9.2 0 -9.1 -9.3 01/06/2007 07:00:00 0.7 0.6 3 0.4 0.7 0.7 3 0.4 0.7 0.6 3 0.4 252 30 285 165 -9.2 0.1 -8.9 -9.5 01/06/2007 07:10:00 2.1 0.3 3 1.1 2.2 0.3 3 1.1 1.9 0.4 2.6 1.1 285 6 291 165 -8.9 0 -8.7 -9.3 01/06/2007 07:20:00 3.1 0.9 5.7 1.5 3.3 1 6.5 1.5 3.3 0.9 6.1 1.5 271 8 278 165 -8.7 0.1 -8.1 -8.9 01/06/2007 07:30:00 3.3 1.3 6.8 0.7 3.5 1.3 6.8 1.5 3.4 1.5 7.6 1.1 259 28 271 165 -8.2 0.2 -7.6 -8.5 01/06/2007 07:40:00 2.4 0.5 3.8 1.1 2.6 0.5 3.8 1.5 2.5 0.5 3.8 1.1 275 7 277 165 -8.5 0.1 -8.3 -8.7 01/06/2007 07:50:00 3.3 0.5 4.9 2.3 3.2 0.6 4.9 1.9 3 0.5 4.6 1.9 311 15 310 165 -8.7 0 -8.5 -8.9 01/06/2007 08:00:00 3.4 0.7 5.3 1.5 3.3 0.8 5.3 1.5 2.8 0.6 4.2 1.1 312 18 318 165 -8.9 0 -8.7 -9.1 01/06/2007 08:10:00 5.4 1 8 2.3 5.4 1 8 2.3 4.6 1.1 8 1.9 298 11 305 165 -8.8 0.1 -8.5 -9.1 01/06/2007 08:20:00 7.4 1 10.3 4.9 7.3 1 10.3 4.6 6.7 1 9.1 4.2 310 9 293 165 -8.9 0 -8.7 -9.1 01/06/2007 08:30:00 6.7 1 9.1 3.4 6.6 1 9.5 3.8 5.7 1 8.8 3 305 8 307 165 -9.1 0 -8.9 -9.1 01/06/2007 08:40:00 7.4 1 9.9 4.9 7.2 1 9.9 4.6 6.5 1.1 8.8 3.8 309 9 303 165 -9.2 0 -8.9 -9.3 01/06/2007 08:50:00 6.9 0.8 9.1 4.9 6.8 0.8 9.5 4.9 6.3 0.8 8.8 3.8 310 6 316 165 -9.1 0 -8.9 -9.3 01/06/2007 09:00:00 6.5 0.7 8.4 4.6 6.4 0.8 8.4 4.6 5.5 0.7 7.6 3.4 303 12 305 165 -9.1 0 -8.9 -9.3 01/06/2007 09:10:00 7.5 1.2 11.1 4.9 7.5 1.2 10.7 4.9 6.2 1 9.5 3.8 302 9 309 165 -9.1 0 -8.9 -9.3 01/06/2007 09:20:00 7.7 1.1 10.7 4.9 7.6 1.1 10.3 4.9 6.1 1 9.5 3.8 295 10 301 165 -9.1 0 -8.9 -9.3 01/06/2007 09:30:00 8.5 1.1 12.2 5.7 8.5 1.1 11.8 5.7 6.7 1.1 11.1 4.6 295 11 301 165 -9.1 0 -8.9 -9.3 01/06/2007 09:40:00 7.7 1.2 10.7 4.9 7.7 1.2 10.7 5.3 6.1 1.1 9.9 3.8 293 11 268 165 -9.1 0 -8.9 -9.3 01/06/2007 09:50:00 8.9 1 11.5 6.5 8.9 1 11.8 6.5 7.3 1.2 10.7 4.6 290 11 290 165 -9.2 0 -9.1 -9.3 01/06/2007 10:00:00 8.9 1 13 6.5 8.9 1 12.6 6.1 7.4 1.1 10.7 4.6 287 8 290 165 -9.2 0 -9.1 -9.3 01/06/2007 10:10:00 10.2 0.8 12.6 8 10.2 0.8 12.6 8.4 8.5 1.3 11.8 5.7 288 8 294 165 -9.3 0 -9.1 -9.3 01/06/2007 10:20:00 8.3 0.9 10.3 6.1 8.2 0.9 9.9 5.7 6.5 1 9.1 4.6 297 10 241 165 -9.4 0.1 -9.1 -9.7 01/06/2007 10:30:00 8.8 0.8 11.1 6.1 8.8 0.8 11.5 6.5 7.1 1.3 11.1 4.6 289 9 247 165 -9.1 0 -8.9 -9.3 01/06/2007 10:40:00 9.3 1.1 12.6 6.5 9.2 1.1 12.2 6.5 7.4 1.3 10.3 4.6 291 11 284 165 -9 0 -8.9 -9.1 01/06/2007 10:50:00 6.7 1.1 10.7 3.4 6.6 1.1 10.3 3.4 5.9 1 8.8 3.4 301 14 287 165 -8.9 0 -8.5 -9.1 01/06/2007 11:00:00 7.3 1.1 10.3 4.9 7.2 1.1 10.3 4.6 6.2 1.3 9.9 3.4 290 11 276 165 -8.9 0 -8.7 -9.1 01/06/2007 11:10:00 6.9 1 9.5 4.2 6.8 1.1 9.9 4.2 5.8 1.1 8.8 3 296 13 307 165 -9 0 -8.7 -9.1 01/06/2007 11:20:00 7.5 1.3 11.5 4.6 7.4 1.4 11.1 4.9 6.3 1 10.3 4.2 304 12 291 165 -9 0.1 -8.7 -9.1 01/06/2007 11:30:00 7.7 0.9 9.9 5.7 7.6 0.9 9.9 5.7 6.9 1.1 9.9 4.2 306 11 297 165 -9.1 0 -8.9 -9.3 01/06/2007 11:40:00 8.2 1 10.7 5.7 8.1 1 10.7 5.7 7.3 1.1 10.7 4.9 308 10 292 165 -9.4 0 -9.1 -9.5 01/06/2007 11:50:00 8.2 1.3 11.5 4.9 8.1 1.3 11.5 4.9 6.8 1.4 11.1 3.8 300 11 307 165 -9.5 0 -9.3 -9.7 01/06/2007 12:00:00 9.4 1.3 13.3 5.3 9.3 1.3 13.3 5.3 8.1 1.5 13 4.9 306 11 302 165 -9.7 0 -9.5 -9.7 01/06/2007 12:10:00 9.1 1.1 11.8 6.1 9 1.1 11.8 6.5 7.5 1.1 10.3 4.6 302 12 296 165 -9.8 0 -9.7 -10 01/06/2007 12:20:00 8.9 1.3 12.6 5.7 8.8 1.4 12.6 5.7 7.8 1.6 11.5 4.6 302 12 310 165 -9.9 0 -9.7 -10.2 01/06/2007 12:30:00 9.4 1.5 13.3 6.1 9.3 1.5 13.3 6.1 8.5 1.6 13.3 4.6 306 12 287 165 -10 0 -9.7 -10.2 01/06/2007 12:40:00 9.6 2.3 15.3 5.3 9.4 2.3 15.3 4.9 8.4 2 13.3 4.6 303 14 300 165 -10.1 0 -9.7 -10.2 01/06/2007 12:50:00 7.7 1.6 11.8 4.2 7.6 1.6 12.2 3 6.6 1.7 11.5 3 298 15 326 165 -9.8 0.1 -9.7 -10.2 01/06/2007 13:00:00 8.4 1.6 11.5 4.9 8.3 1.5 11.5 4.9 7.4 1.7 11.5 3.4 299 15 262 165 -9.9 0 -9.7 -10.2 01/06/2007 13:10:00 7.6 1.2 10.7 5.3 7.5 1.2 11.1 4.9 6.4 1.2 10.7 2.6 295 15 247 165 -9.9 0 -9.7 -10 01/06/2007 13:20:00 8.3 1.2 11.5 5.3 8.2 1.2 11.5 4.9 7 1.1 10.7 4.6 296 13 287 165 -9.7 0.1 -9.5 -10.2 01/06/2007 13:30:00 7.8 1.1 9.9 4.6 7.7 1.1 9.9 4.9 6.6 1 9.1 4.2 291 12 289 165 -9.8 0 -9.7 -10 01/06/2007 13:40:00 7.1 1 9.9 4.6 7 1.1 10.7 4.6 5.8 1.1 9.9 3.4 296 13 284 165 -9.9 0 -9.7 -10.2 01/06/2007 13:50:00 7.1 1.5 10.3 3.8 7 1.5 10.3 3.8 5.9 1.5 9.5 3 294 13 297 165 -9.8 0 -9.7 -10 01/06/2007 14:00:00 7.1 1 9.9 4.9 7 1 9.9 4.9 6 1.2 9.5 3.8 291 12 287 165 -9.7 0 -9.5 -10 01/06/2007 14:10:00 7.5 1 10.3 3.8 7.4 1 10.3 4.2 6.1 1.1 9.5 4.2 291 11 284 165 -9.8 0 -9.7 -10 01/06/2007 14:20:00 7.5 1.2 10.3 4.9 7.4 1.2 10.7 4.9 6 1.1 9.1 3.4 295 14 285 165 -9.6 0 -9.3 -9.7 01/06/2007 14:30:00 8.8 1.5 12.6 4.9 8.7 1.5 12.2 4.9 7.5 1.5 11.1 4.2 285 12 278 165 -9.3 0.1 -8.9 -9.7 01/06/2007 14:40:00 9.5 1.5 13.3 6.5 9.4 1.5 13.3 6.5 7.8 1.6 12.2 4.6 290 14 292 165 -9.1 0 -8.9 -9.3 01/06/2007 14:50:00 9.1 1.1 11.8 4.6 9.2 1.1 11.8 6.1 7.6 1.3 11.5 4.6 287 13 272 165 -9.1 0 -8.9 -9.3 01/06/2007 15:00:00 9.9 1.6 14.1 5.7 10 1.5 14.1 6.8 9.5 1.7 13.7 5.7 279 9 282 165 -9.1 0 -8.9 -9.3 01/06/2007 15:10:00 8.2 1.8 13 3.4 8.6 1.5 13 5.7 8.1 1.6 13 4.6 277 13 279 165 -9.1 0.1 -8.9 -9.3 01/06/2007 15:20:00 9 1.1 12.6 5.7 9.1 1.1 12.6 6.5 8.5 1.3 11.8 5.3 280 8 280 165 -9.4 0.2 -9.1 -9.7 01/06/2007 15:30:00 11.1 2.2 16.4 6.1 11.1 2.2 16.4 6.5 10 2.3 16.8 5.3 285 9 289 165 -9.5 0 -9.3 -9.7 01/06/2007 15:40:00 11.2 1.8 16.1 7.2 11.3 1.8 16.8 7.6 10.8 2 16.8 6.8 279 9 278 165 -9.6 0.1 -9.3 -9.7 01/06/2007 15:50:00 11.6 1.2 14.9 8.4 11.5 1.2 14.9 8 10.5 1.5 13.7 6.8 284 9 276 165 -9.7 0 -9.5 -10.2 01/06/2007 16:00:00 11.7 1.8 16.1 6.5 11.7 1.7 15.6 7.2 10.7 2 15.6 6.1 279 9 268 165 -10 0 -9.7 -10.2 01/06/2007 16:10:00 13.3 1.6 17.9 9.5 13.4 1.6 17.9 9.9 12.4 1.9 17.9 7.6 280 9 277 165 -10.1 0 -10 -10.2 01/06/2007 16:20:00 15.2 1.2 18.3 11.8 15.2 1.2 18.3 11.5 14.1 1.7 17.9 9.5 280 9 281 165 -10.1 0 -9.7 -10.2 01/06/2007 16:30:00 13.7 1.3 17.2 10.3 13.6 1.3 17.6 10.3 11.4 1.5 15.6 7.6 287 9 289 165 -10.1 0 -10 -10.2 01/06/2007 16:40:00 11.5 1.2 16.1 8 11.4 1.2 15.6 8 9.9 1.5 14.5 6.5 287 11 253 165 -10.2 0 -10 -10.4 01/06/2007 16:50:00 12.4 1.5 17.2 9.5 12.3 1.4 16.8 9.1 10.2 1.5 14.5 5.7 292 13 289 165 -10.2 0 -10 -10.4 01/06/2007 17:00:00 12.7 2 17.6 7.6 12.6 2 17.9 7.6 10.8 2.4 17.2 6.5 285 12 277 165 -10.2 0 -10 -10.4 01/06/2007 17:10:00 12.7 1.5 17.6 8.8 12.6 1.5 17.2 8.8 10 1.5 15.3 6.5 294 13 302 165 -10.3 0 -10.2 -10.6 01/06/2007 17:20:00 13 2.6 19.1 8 12.8 2.6 18.7 8 10.4 2.3 17.2 6.8 294 14 304 165 -10.4 0 -10.2 -10.6 01/06/2007 17:30:00 11.1 1.8 14.9 6.8 11 1.8 15.6 7.2 9.4 2 14.5 5.3 298 14 302 165 -10.6 0 -10.6 -10.8 01/06/2007 17:40:00 10.4 1.9 16.4 6.1 10.3 1.9 16.4 6.1 9 2 14.1 4.9 299 15 307 165 -10.7 0.1 -10.6 -11 01/06/2007 17:50:00 10.2 1.9 15.6 4.9 10.1 1.8 15.6 5.3 8.3 1.6 12.6 4.6 299 13 302 165 -10.8 0 -10.6 -11 01/06/2007 18:00:00 8.9 1.7 14.1 4.9 8.8 1.7 13.7 4.9 7.3 1.4 11.5 4.2 294 15 307 165 -10.9 0.1 -10.6 -11.2 01/06/2007 18:10:00 9.5 1.5 15.3 6.1 9.4 1.5 14.5 6.1 8.2 1.4 13.3 4.6 290 14 298 165 -10.7 0.1 -10.6 -11 01/06/2007 18:20:00 9.4 1.7 13.3 5.3 9.3 1.6 13.3 4.9 8 1.5 13.3 3.4 295 16 315 165 -10.7 0 -10.6 -10.8 01/06/2007 18:30:00 9.4 1.5 13.3 5.7 9.3 1.5 13.3 5.7 7.7 1.2 11.5 4.9 294 13 297 165 -10.6 0 -10.6 -10.8 01/06/2007 18:40:00 4.6 2.6 10.3 0.4 4.6 2.5 10.7 0.4 4.3 2.2 11.1 1.1 289 24 314 165 -10.8 0 -10.6 -11 01/06/2007 18:50:00 4.5 1.5 9.1 0.7 5 1.7 9.5 0.7 4.4 1.8 8.8 0.4 266 17 280 165 -10.9 0 -10.6 -11.2 01/06/2007 19:00:00 5 1.3 9.9 1.9 5.1 1.3 9.5 1.9 4.6 1.2 8.8 1.5 278 17 274 165 -10.8 0 -10.6 -11 01/06/2007 19:10:00 6.1 1.8 10.3 2.3 6.3 1.6 10.3 3 6 1.3 9.5 2.6 278 17 268 165 -10.8 0 -10.6 -11 01/06/2007 19:20:00 8.5 1.6 11.5 4.6 8.5 1.5 11.5 4.6 7.5 1.5 11.5 4.2 282 11 284 165 -10.8 0 -10.6 -11 01/06/2007 19:30:00 8.3 1.8 14.1 3.8 8.3 1.8 13.7 3.8 7.5 2 13.7 3 289 18 284 165 -10.9 0.2 -10.6 -11.4 01/06/2007 19:40:00 7.9 1.2 11.5 4.9 7.9 1.2 11.1 4.9 7 1.3 10.3 3.8 285 13 298 165 -11.1 0 -11 -11.4 01/06/2007 19:50:00 8.3 1.5 12.6 4.6 8.3 1.5 12.6 4.9 7.3 1.7 11.5 3.8 284 13 274 165 -10.8 0.1 -10.6 -11.4 01/06/2007 20:00:00 8.8 1.5 13 5.3 8.8 1.5 13 5.3 7.9 1.7 12.6 3.4 281 11 281 165 -10.8 0.1 -10.6 -11 01/06/2007 20:10:00 7.3 1.3 11.1 3.4 7.3 1.3 11.1 3.4 6.4 1.5 10.3 3 283 12 284 165 -10.9 0 -10.8 -11.2 01/06/2007 20:20:00 6.1 1.1 8.8 3.4 6.1 1.1 8.8 3 5.3 1.2 8.4 2.6 290 13 274 165 -11.2 0 -11 -11.4 01/06/2007 20:30:00 8 1 10.7 4.2 7.9 1.1 10.7 4.2 6.7 1.2 9.9 3.8 289 11 285 165 -11.1 0 -11 -11.4 01/06/2007 20:40:00 7 1.4 9.9 3.8 6.9 1.4 9.9 3.8 6 1.3 9.9 3 303 11 310 165 -11.3 0.1 -11 -11.6 01/06/2007 20:50:00 5.5 0.8 7.2 3.8 5.4 0.8 7.2 3.4 5.3 0.8 7.2 3.4 317 8 315 165 -11.8 0.1 -11.4 -12.2 01/06/2007 21:00:00 5.6 0.7 7.2 3.8 5.5 0.7 7.2 3.8 5.4 0.6 7.2 3.4 318 8 310 165 -12.1 0 -11.8 -12.4 01/06/2007 21:10:00 5.8 0.6 7.6 4.2 5.7 0.7 7.6 4.2 5.3 0.7 7.2 3.8 310 9 297 165 -12.4 0 -12.2 -12.6 01/06/2007 21:20:00 5.3 0.8 7.6 3 5.3 0.8 7.6 3 5.2 0.9 7.2 2.6 320 13 301 165 -12.6 0 -12.4 -13 01/06/2007 21:30:00 7.1 1.3 9.5 3.4 7 1.3 9.9 2.6 6.5 1.2 9.5 3.8 312 13 315 165 -12.7 0 -12.6 -13 01/06/2007 21:40:00 8.1 1.1 11.1 5.7 8 1.1 10.7 5.3 7.7 1.2 10.7 4.6 312 8 301 165 -12.9 0.1 -12.6 -13 01/06/2007 21:50:00 8.6 0.8 11.5 6.5 8.5 0.8 11.1 6.5 8.3 1 11.8 5.3 316 9 316 165 -12.9 0 -12.6 -13.2 01/06/2007 22:00:00 9 1.1 11.5 6.8 8.8 1.1 11.5 6.8 8.5 1.4 11.5 5.3 316 10 315 165 -13.1 0 -13 -13.4 01/06/2007 22:10:00 8.7 0.8 10.7 6.5 8.6 0.8 10.7 6.5 8.7 0.8 10.7 6.5 319 6 327 165 -13.1 0 -13 -13.4 01/06/2007 22:20:00 7.9 0.7 10.3 6.1 7.8 0.7 10.3 6.1 7.7 0.8 9.9 3.8 318 9 321 165 -13.2 0 -13.2 -13.6 01/06/2007 22:30:00 8.2 0.7 10.3 6.1 8.1 0.7 9.9 6.1 8.1 0.8 10.3 6.1 317 6 310 165 -13.3 0 -13.2 -13.6 01/06/2007 22:40:00 8 0.8 10.3 6.1 8 0.9 10.7 6.1 7.4 1.1 9.9 4.9 309 8 310 165 -13.2 0 -13.2 -13.6 01/06/2007 22:50:00 7.7 0.8 9.5 6.1 7.6 0.8 9.5 5.7 6.8 1 8.8 4.2 308 7 309 165 -13.4 0 -13.2 -13.6 01/06/2007 23:00:00 8.9 0.6 10.3 7.2 8.9 0.7 10.3 7.2 7.2 0.9 9.1 5.3 303 8 287 165 -13.6 0 -13.2 -14 01/06/2007 23:10:00 9.6 0.7 11.5 8 9.6 0.7 11.5 8 7.7 1.1 10.7 4.9 302 10 287 165 -13.5 0.1 -13.4 -13.8 01/06/2007 23:20:00 9.2 0.8 11.5 7.6 9.3 0.8 11.5 7.6 7 1.1 10.7 4.6 294 9 294 165 -13.5 0 -13.2 -13.6 01/06/2007 23:30:00 9.4 0.8 12.2 6.8 9.4 0.8 11.8 6.8 8.1 1 11.1 5.3 304 8 308 165 -13.7 0 -13.6 -14 01/06/2007 23:40:00 9.7 0.9 12.2 7.6 9.7 0.9 12.2 7.6 7.7 1 9.9 5.3 302 11 287 165 -13.9 0 -13.6 -14 01/06/2007 23:50:00 10.5 0.8 13 8.4 10.4 0.8 13 8.4 8.5 1.1 11.5 5.7 303 10 293 165 -13.8 0 -13.6 -14 01/07/2007 00:00:00 10.3 1.5 14.9 7.6 10.3 1.4 14.9 7.6 8.8 1.4 12.6 5.7 305 8 290 165 -13.8 0 -13.6 -14 01/07/2007 00:10:00 10.4 1.2 14.1 7.6 10.3 1.2 14.1 7.6 8.8 1.5 13 5.7 302 13 307 165 -14 0 -13.8 -14 01/07/2007 00:20:00 10.7 1 13.3 8 10.7 0.9 13.3 7.6 8.6 1.4 12.2 5.7 301 11 301 165 -14.1 0 -14 -14.2 01/07/2007 00:30:00 12.1 1.1 15.3 9.5 12 1 14.9 9.5 10.2 1.7 14.9 6.1 302 12 298 165 -13.9 0 -13.6 -14.2 01/07/2007 00:40:00 11.2 1 13.7 8.8 11.1 1 13.7 8.8 9.3 1.5 13.3 6.1 302 12 307 165 -13.8 0.1 -13.6 -14 01/07/2007 00:50:00 11.5 1.1 14.5 9.1 11.4 1 14.5 8.8 10.6 1.3 13.3 6.8 307 11 312 165 -14 0.1 -13.6 -14.2 01/07/2007 01:00:00 12.4 1.3 16.1 9.5 12.3 1.3 15.6 9.5 11.4 1.5 14.9 7.2 309 9 309 165 -14 0 -13.8 -14 01/07/2007 01:10:00 12.2 1.2 15.3 9.1 12 1.2 14.9 8.8 10.9 1.5 14.5 6.8 307 10 307 165 -13.8 0 -13.6 -14 01/07/2007 01:20:00 13 1 15.3 8.8 12.8 1 14.9 8.4 12.1 1.3 15.6 8 310 7 312 165 -13.9 0 -13.8 -14 01/07/2007 01:30:00 13.9 1.3 17.6 9.9 13.6 1.3 17.2 10.3 12.9 1.7 16.8 7.2 309 9 309 165 -14 0.1 -13.6 -14 01/07/2007 01:40:00 11.5 1.2 14.1 8.8 11.3 1.1 13.7 8.8 11 1.3 14.5 7.2 312 9 309 165 -14.1 0 -14 -14.4 01/07/2007 01:50:00 11.8 1.1 14.5 9.1 11.5 1 14.1 9.1 11.5 1.2 14.5 8.4 315 7 320 165 -14.2 0 -14 -14.4 01/07/2007 02:00:00 11.9 1 14.1 9.5 11.7 1 13.7 9.1 11.2 1.2 14.1 8.4 310 9 316 165 -14 0.1 -13.6 -14.4 01/07/2007 02:10:00 11.3 1.5 14.9 8 11.2 1.5 14.5 8 10.2 1.6 14.5 6.5 308 10 309 165 -13.8 0 -13.6 -14 01/07/2007 02:20:00 9.8 1.1 13 6.8 9.7 1.1 12.6 6.5 9.6 1.4 13.3 6.1 313 9 316 165 -14 0.1 -13.8 -14.2 01/07/2007 02:30:00 9.7 1 13 7.2 9.6 1 12.6 6.8 9.5 1.2 13 6.1 313 8 307 165 -14.1 0 -14 -14.2 01/07/2007 02:40:00 12.3 1.3 14.9 8.4 12 1.2 14.9 8 12.1 1.5 15.6 6.8 313 6 316 165 -14.1 0 -14 -14.2 01/07/2007 02:50:00 12.2 1 14.9 9.1 12 1 14.5 9.1 12 1.2 15.6 8.8 316 8 312 165 -14.2 0 -14 -14.4 01/07/2007 03:00:00 13.7 0.9 16.1 10.7 13.4 0.9 15.6 10.3 13 1.1 16.1 9.5 311 7 314 165 -14.1 0 -14 -14.2 01/07/2007 03:10:00 12.1 2 15.6 7.6 11.9 1.9 16.1 7.2 10.8 2.3 15.3 5.7 304 10 302 165 -14 0 -13.8 -14 01/07/2007 03:20:00 10.4 1.7 13.7 5.7 10.3 1.7 13.7 4.9 9.5 1.9 13.3 5.3 310 11 313 165 -14 0 -13.6 -14 01/07/2007 03:30:00 12.1 1 14.5 9.1 11.9 1 14.1 8.8 12 1.2 14.9 8 318 6 319 165 -13.8 0 -13.6 -14 01/07/2007 03:40:00 14.3 1.5 17.2 10.7 14 1.5 16.8 10.7 13.9 1.6 16.8 9.9 315 5 315 165 -14 0 -13.8 -14 01/07/2007 03:50:00 16.6 1 19.5 11.5 16.3 1 19.1 11.1 16.1 1.2 19.1 11.1 316 6 315 165 -13.7 0 -13.6 -14 01/07/2007 04:00:00 18 1 20.2 14.1 17.8 1 20.2 14.1 17.1 1.2 21.4 14.1 312 5 313 165 -13.7 0 -13.6 -14 01/07/2007 04:10:00 17.1 1.3 20.2 14.1 16.8 1.3 20.2 14.1 15.7 1.3 19.1 12.2 308 7 307 165 -13.8 0 -13.6 -14 01/07/2007 04:20:00 15.4 1 17.6 13 15.1 1 17.6 12.6 13.7 1.2 16.4 10.7 306 8 307 165 -14 0 -13.8 -14 01/07/2007 04:30:00 14.3 1.5 17.6 11.1 14.1 1.5 17.6 11.1 12.8 1.5 17.2 8.4 305 9 292 165 -14.1 0 -14 -14.4 01/07/2007 04:40:00 12.7 1.3 15.3 9.1 12.5 1.2 14.9 9.5 11.5 1.5 14.5 7.6 304 10 302 165 -14.4 0 -14.2 -14.6 01/07/2007 04:50:00 13.9 0.6 15.6 11.8 13.7 0.6 15.3 12.2 13.4 0.7 14.9 11.1 311 5 307 165 -14.5 0 -14.4 -14.6 01/07/2007 05:00:00 12.5 0.8 14.9 10.7 12.4 0.8 14.9 10.3 11.7 1.2 14.9 8 309 7 313 165 -14.6 0 -14.6 -14.8 01/07/2007 05:10:00 10.6 1.1 14.1 8 10.6 1 14.5 7.6 9.9 1.1 13.3 7.2 310 6 310 165 -14.6 0 -14.4 -14.8 01/07/2007 05:20:00 8.8 0.8 11.1 6.1 8.8 0.9 11.5 6.1 7.7 1 10.7 5.3 304 8 268 165 -14.5 0 -14.4 -14.6 01/07/2007 05:30:00 6.7 1.1 10.3 3.4 6.7 1.1 9.5 3.4 5.8 1.3 9.1 3 308 9 307 165 -14.5 0 -14.4 -14.6 01/07/2007 05:40:00 5.9 0.5 7.2 4.2 5.9 0.5 7.2 4.2 5.6 0.6 6.8 3 319 13 303 165 -14.6 0 -14.4 -14.8 01/07/2007 05:50:00 5.3 0.7 6.8 3 5.1 0.7 6.5 3 4.9 0.6 6.1 2.6 326 11 307 165 -14.7 0 -14.6 -14.8 01/07/2007 06:00:00 4.5 0.6 6.1 2.6 4.2 0.7 5.7 2.3 4.3 0.7 6.1 2.3 340 14 341 165 -14.7 0 -14.6 -15 01/07/2007 06:10:00 7.8 1.9 11.5 3.4 7.8 2 11.8 3.4 6.9 1.7 10.7 3 307 13 300 165 -14.6 0 -14.4 -15 01/07/2007 06:20:00 7.9 1 10.3 5.3 7.9 1 10.7 5.3 7 1.1 10.3 4.6 309 11 305 165 -14.8 0 -14.6 -15 01/07/2007 06:30:00 6.7 1 9.1 4.2 6.7 1 9.1 4.2 5.9 1 8.8 3 310 11 307 165 -15 0 -14.8 -15.2 01/07/2007 06:40:00 9.3 1.5 12.2 5.7 9.3 1.5 11.8 5.3 8.4 1.8 11.8 4.6 310 9 307 165 -14.9 0 -14.8 -15.2 01/07/2007 06:50:00 10.1 1.2 13 6.1 10 1.1 13 5.7 9.4 1.3 13.3 5.7 312 8 310 165 -14.8 0 -14.6 -15 01/07/2007 07:00:00 8.3 1 10.7 5.3 8.3 1 10.7 5.3 8 1.4 11.1 4.6 314 10 317 165 -14.8 0 -14.6 -15 01/07/2007 07:10:00 8 0.8 9.9 5.7 7.9 0.8 10.3 6.1 7.5 1 10.7 4.9 312 7 312 165 -14.9 0 -14.8 -15 01/07/2007 07:20:00 8 0.7 10.3 6.1 7.9 0.7 9.9 6.1 7.8 0.8 10.3 5.3 316 7 322 165 -14.9 0 -14.8 -15.2 01/07/2007 07:30:00 9.1 1 11.8 6.5 9 1 11.8 6.5 8.8 1 11.1 6.1 314 7 312 165 -14.7 0.1 -14.6 -15 01/07/2007 07:40:00 10.8 1.2 14.1 8 10.7 1.1 14.1 8 10.2 1.1 13.3 7.2 313 8 300 165 -14.6 0 -14.4 -15 01/07/2007 07:50:00 10.7 1.1 12.6 7.2 10.6 1 13 7.2 9.8 1.2 13 6.5 311 11 316 165 -14.6 0 -14.4 -14.6 01/07/2007 08:00:00 11 1.4 14.1 6.5 11 1.3 13.7 6.5 9.7 1.5 13.3 5.3 305 10 302 165 -14.5 0 -14.4 -14.6 01/07/2007 08:10:00 12.4 1.5 15.6 8.4 12.3 1.4 15.6 8.8 11.3 1.7 15.3 7.6 310 12 296 165 -14.2 0.1 -14 -14.6 01/07/2007 08:20:00 12.4 1.7 16.1 8.4 12.2 1.7 16.1 8.4 11.3 1.9 16.1 6.8 306 12 306 165 -14.2 0 -14 -14.4 01/07/2007 08:30:00 12 1.7 16.1 8 12 1.7 16.4 8.4 11 2.2 16.4 6.5 316 11 319 165 -14.4 0 -14.2 -14.6 01/07/2007 08:40:00 12.7 1.9 17.2 8.4 12.6 1.8 16.8 8 11.2 2.4 16.1 3 309 15 289 165 -14.6 0 -14.4 -14.6 01/07/2007 08:50:00 12.1 2.1 16.4 5.3 12.1 2.1 16.4 6.1 10 2.2 15.3 2.3 302 17 301 165 -14.7 0 -14.4 -15 01/07/2007 09:00:00 12.2 1.7 16.4 6.8 12.2 1.6 16.1 7.2 10.8 2.1 16.4 3 302 16 317 165 -14.9 0 -14.6 -15 01/07/2007 09:10:00 13.1 1.7 16.8 7.6 12.9 1.6 16.8 7.2 11.7 1.8 15.6 4.9 305 13 301 165 -14.8 0 -14.6 -15 01/07/2007 09:20:00 10.2 2.3 16.1 6.1 10.2 2.2 15.3 5.3 9.4 2.4 16.1 4.2 311 13 328 165 -14.8 0 -14.6 -15 01/07/2007 09:30:00 12.6 1.7 16.4 8 12.4 1.6 16.4 8.4 11.8 1.7 17.2 6.8 313 13 310 165 -14.7 0 -14.6 -15 01/07/2007 09:40:00 14.5 1.3 17.6 11.5 14.3 1.3 17.6 11.5 13.7 1.5 17.2 8.8 312 13 301 165 -14.6 0 -14.6 -15 01/07/2007 09:50:00 13.2 1.6 18.3 9.5 13 1.6 18.3 9.5 12.7 1.7 17.6 9.1 318 12 301 165 -14.7 0 -14.6 -15 01/07/2007 10:00:00 13.9 1.6 17.9 10.3 13.7 1.6 18.3 9.9 13.1 1.7 18.7 9.1 311 11 316 165 -14.7 0 -14.6 -15 01/07/2007 10:10:00 12.7 1.2 16.1 8.8 12.5 1.2 15.6 8.4 11.9 1.3 16.1 7.6 310 10 316 165 -14.9 0 -14.6 -15 01/07/2007 10:20:00 14 1.7 18.3 9.9 13.8 1.7 18.3 10.3 13.4 1.9 18.3 8.4 310 12 273 165 -14.7 0.1 -14.6 -15 01/07/2007 10:30:00 13.3 1.7 19.1 8.4 13.2 1.6 18.7 8.8 12.7 1.8 16.8 6.8 310 10 305 165 -14.6 0 -14.4 -14.8 01/07/2007 10:40:00 13.1 1.7 17.6 8.8 13 1.7 17.9 9.1 12.6 1.9 17.9 7.6 311 9 305 165 -14.3 0 -14 -14.6 01/07/2007 10:50:00 14.7 1.6 18.3 10.7 14.6 1.7 18.3 11.1 14 1.7 19.1 9.5 310 11 316 165 -14.1 0 -14 -14.2 01/07/2007 11:00:00 14.2 1.6 18.3 10.7 14.1 1.6 18.3 10.3 13.6 1.5 18.7 9.1 308 11 322 165 -14.1 0 -13.8 -14.2 01/07/2007 11:10:00 11.1 1.8 14.5 6.8 11 1.7 14.1 6.8 10.4 1.8 14.1 5.7 306 10 294 165 -13.9 0 -13.6 -14 01/07/2007 11:20:00 11.4 2.4 17.2 6.8 11.3 2.4 17.2 7.2 9.5 2.4 16.4 4.9 288 13 285 165 -13.6 0.1 -13.4 -14 01/07/2007 11:30:00 13.1 1.3 18.3 9.9 13 1.3 18.7 9.9 11.5 1.8 17.9 7.2 285 14 284 165 -13.5 0 -13.4 -13.6 01/07/2007 11:40:00 13.3 1.8 18.3 9.1 13.2 1.8 18.3 9.5 11.8 2.1 17.6 6.5 294 17 310 165 -13.5 0 -13.2 -13.6 01/07/2007 11:50:00 15.8 1.9 19.9 10.3 15.7 1.9 19.5 10.3 15.4 2.1 20.2 10.7 314 12 322 165 -13.6 0 -13.4 -13.8 01/07/2007 12:00:00 14 2.7 20.2 7.2 13.8 2.7 19.5 6.8 13.6 2.6 20.2 6.5 318 17 304 165 -13.5 0 -13.2 -13.8 01/07/2007 12:10:00 17.2 3.1 24.4 8.8 17.1 3.1 24.8 8.8 16.3 3.3 24.4 7.2 308 13 295 165 -13.4 0 -13.2 -13.6 01/07/2007 12:20:00 19.6 1.7 24.8 14.1 19.5 1.8 24.8 14.1 19.4 2 24 14.1 315 9 313 165 -13.3 0 -13.2 -13.6 01/07/2007 12:30:00 19.1 1.5 24.4 15.6 19 1.5 24.4 14.9 19 1.7 24.4 14.5 313 8 319 165 -13.1 0 -13 -13.4 01/07/2007 12:40:00 20.7 1.6 25.2 16.1 20.4 1.7 24.8 15.6 20.8 1.7 25.2 16.4 318 6 318 165 -13.2 0 -13 -13.4 01/07/2007 12:50:00 20.3 1.7 24.8 14.5 20.1 1.7 24.4 14.1 20.2 1.7 25.6 15.3 316 7 310 165 -13.4 0 -13.2 -13.6 01/07/2007 13:00:00 18.9 2 24 14.1 18.7 2 24 14.5 18.6 2.2 23.7 12.6 314 8 312 165 -13.2 0.1 -13 -13.6 01/07/2007 13:10:00 17.8 1.7 22.6 13.7 17.5 1.7 22.1 13.7 17.6 1.8 22.1 13.3 315 8 328 165 -13.1 0 -13 -13.2 01/07/2007 13:20:00 19.6 1.6 22.6 16.1 19.3 1.6 22.6 15.6 19.5 1.9 23.7 14.1 320 7 324 165 -13.2 0 -13 -13.4 01/07/2007 13:30:00 18.5 1.3 21.8 14.9 18.3 1.4 22.1 14.9 18.5 1.5 23.3 14.1 314 7 296 165 -13.4 0.1 -13.2 -13.6 01/07/2007 13:40:00 17.9 1.5 21.4 13.3 17.6 1.5 21.4 13.3 17.8 1.6 21.8 13.3 316 8 312 165 -13.4 0 -13.2 -13.6 01/07/2007 13:50:00 16.6 1.5 20.6 12.6 16.5 1.5 20.2 12.6 16.3 1.7 20.2 11.5 315 9 321 165 -13.2 0 -13.2 -13.6 01/07/2007 14:00:00 16.5 1.9 21.8 11.1 16.4 1.9 21 11.5 16 2.1 20.2 10.7 313 10 301 165 -13.4 0.1 -13.2 -13.6 01/07/2007 14:10:00 18.8 1.5 22.9 14.1 18.6 1.5 23.3 14.1 18 1.5 21.8 13 310 8 299 165 -13.5 0 -13.4 -13.6 01/07/2007 14:20:00 16.1 1.8 20.6 11.5 15.8 1.8 20.2 11.5 15.5 1.8 20.6 11.1 315 9 316 165 -13.4 0 -13.2 -13.6 01/07/2007 14:30:00 16.6 1.7 21.4 13 16.4 1.7 21.4 13 16.2 1.8 21.4 11.8 313 10 304 165 -13.3 0 -13.2 -13.6 01/07/2007 14:40:00 18.4 1.5 22.1 14.1 18.1 1.5 21.8 14.5 18 1.5 21.4 13 313 7 304 165 -13 0 -12.8 -13.4 01/07/2007 14:50:00 18.1 1.4 21.4 14.5 17.8 1.3 21 14.5 17.6 1.6 21.4 14.1 309 7 313 165 -13.1 0 -13 -13.2 01/07/2007 15:00:00 15.6 1.1 19.1 12.6 15.4 1.1 18.7 13 15 1.5 18.3 9.5 307 9 307 165 -13.1 0 -13 -13.4 01/07/2007 15:10:00 14.6 1.7 18.7 10.3 14.5 1.7 18.7 9.9 13.8 1.7 18.3 9.1 303 12 290 165 -13.1 0 -13 -13.4 01/07/2007 15:20:00 14.2 2.2 19.9 9.1 14 2.3 19.1 9.1 13 1.9 17.6 8.4 300 13 300 165 -13.2 0 -13.2 -13.4 01/07/2007 15:30:00 17.4 1.5 21 14.1 17.2 1.5 20.6 13.7 14.7 1.7 20.2 11.1 292 14 245 165 -13.3 0 -13.2 -13.6 01/07/2007 15:40:00 17.3 1.3 20.2 13.3 17.2 1.3 20.2 13.3 16.1 1.8 20.6 11.5 300 12 302 165 -13.4 0 -13.2 -13.6 01/07/2007 15:50:00 18 1.2 20.2 15.3 17.9 1.2 20.6 14.9 17.1 1.6 21.4 12.6 305 7 307 165 -13.5 0 -13.2 -13.8 01/07/2007 16:00:00 17.3 1.5 21 13.3 17.1 1.5 21 13.3 16.4 1.5 19.9 11.5 306 9 302 165 -13.4 0 -13.2 -13.6 01/07/2007 16:10:00 16.9 2 20.2 11.8 16.7 2 20.2 11.8 16 2 21.8 11.1 306 10 314 165 -13.4 0 -13.2 -13.6 01/07/2007 16:20:00 15.8 1.5 19.1 11.8 15.6 1.5 19.1 11.5 15.1 1.7 19.1 9.5 308 9 302 165 -13.4 0 -13.2 -13.6 01/07/2007 16:30:00 13.6 1.9 18.3 9.9 13.4 1.9 17.9 9.9 12.6 2.4 19.1 7.2 304 12 315 165 -13.3 0 -13.2 -13.6 01/07/2007 16:40:00 10 1.5 13.7 6.1 9.9 1.5 13.3 5.7 9 1.8 13.3 4.9 299 13 287 165 -13.3 0 -13.2 -13.6 01/07/2007 16:50:00 9.9 1.5 14.1 6.8 9.9 1.5 14.1 6.8 8.3 1.5 13.3 5.3 291 15 299 165 -13.4 0 -13.2 -13.6 01/07/2007 17:00:00 13.5 1.2 15.6 9.5 13.4 1.2 16.4 9.5 10.8 1.7 15.6 7.2 286 12 280 165 -13.4 0 -13.2 -13.6 01/07/2007 17:10:00 13.6 1.3 16.8 10.7 13.6 1.3 17.2 11.1 11.4 2 17.9 7.6 284 12 284 165 -13.5 0 -13.2 -13.6 01/07/2007 17:20:00 14.8 1.3 18.3 11.8 14.8 1.3 18.3 11.5 12.2 1.9 17.6 7.6 283 12 291 165 -13.4 0 -13.2 -13.6 01/07/2007 17:30:00 14.8 1.2 18.3 11.5 14.8 1.2 18.3 10.7 12.6 1.9 18.3 8.4 283 11 262 165 -13.4 0 -13.2 -13.6 01/07/2007 17:40:00 15.6 1.9 20.6 12.2 15.5 1.9 20.2 11.8 13.7 2.5 19.5 8.4 279 11 289 165 -13.4 0 -13.2 -13.6 01/07/2007 17:50:00 16.4 1.2 19.5 12.6 16.4 1.2 19.1 12.2 14.4 1.9 19.1 9.5 280 11 305 165 -13.5 0 -13.2 -13.6 01/07/2007 18:00:00 17.3 1.4 21 13.3 17.4 1.5 21.4 13.3 16.3 2.4 21.4 9.1 277 11 277 165 -13.5 0 -13.4 -13.6 01/07/2007 18:10:00 17.6 1.3 21.8 13.7 17.6 1.4 21.8 13.7 14.8 2.4 22.1 9.9 282 12 277 165 -13.5 0 -13.4 -13.6 01/07/2007 18:20:00 15.2 1.5 18.3 11.8 15.2 1.6 18.7 11.5 11.4 1.7 16.8 7.6 288 13 294 165 -13.6 0 -13.4 -13.8 01/07/2007 18:30:00 16.3 1.5 19.9 11.8 16.2 1.6 19.9 11.8 12.6 1.8 18.7 8.8 284 13 296 165 -13.6 0 -13.4 -13.8 01/07/2007 18:40:00 19.1 1.3 22.1 16.1 19 1.3 22.1 15.6 14.1 1.7 21.4 10.3 287 14 297 165 -13.5 0 -13.2 -13.6 01/07/2007 18:50:00 19 1.2 22.1 15.6 18.9 1.2 21.8 15.6 14.4 2 21 10.7 286 12 285 165 -13.4 0.1 -13.2 -13.6 01/07/2007 19:00:00 17.9 1.3 21.4 14.1 17.8 1.3 21 14.1 13.9 1.7 19.9 10.7 287 14 286 165 -13.5 0 -13.2 -13.8 01/07/2007 19:10:00 14.7 1.7 20.2 10.7 14.5 1.7 20.2 10.7 11.7 1.7 15.6 7.6 293 15 287 165 -13.6 0 -13.4 -13.8 01/07/2007 19:20:00 13.4 1.2 17.2 11.1 13.2 1.2 16.4 10.7 12.1 1.6 16.4 8 301 15 275 165 -13.5 0 -13.4 -13.6 01/07/2007 19:30:00 14.9 1.3 18.3 11.5 14.7 1.3 18.3 11.5 13.9 1.8 18.7 9.5 301 13 303 165 -13.6 0 -13.4 -13.8 01/07/2007 19:40:00 13.6 1.5 18.3 10.3 13.5 1.6 17.9 9.9 11.6 1.7 16.1 8 291 15 279 165 -13.6 0 -13.6 -14 01/07/2007 19:50:00 13.3 1.2 15.6 9.9 13.1 1.2 15.6 9.9 11.3 1.5 15.3 8 290 15 238 165 -13.6 0 -13.6 -13.8 01/07/2007 20:00:00 13.8 1.3 16.8 10.3 13.6 1.4 16.8 10.3 12.1 1.3 15.6 7.6 296 17 305 165 -13.5 0 -13.4 -13.8 01/07/2007 20:10:00 11.7 1.2 14.5 8.8 11.5 1.2 14.9 8.8 11.4 1.2 14.1 8.4 309 8 309 165 -13.5 0 -13.4 -13.6 01/07/2007 20:20:00 10.4 0.7 12.2 8.8 10.3 0.7 11.8 8.8 9.7 0.8 11.8 7.2 305 7 289 165 -13.6 0 -13.6 -13.8 01/07/2007 20:30:00 8.4 1.5 12.2 5.3 8.2 1.3 11.8 5.3 7.9 1.5 12.2 4.9 307 11 310 165 -13.6 0 -13.4 -13.8 01/07/2007 20:40:00 9.9 1.3 14.1 6.8 9.8 1.2 14.1 6.8 8.7 1.3 12.6 5.3 297 15 290 165 -13.5 0 -13.4 -13.6 01/07/2007 20:50:00 12.7 1.3 17.2 9.5 12.6 1.4 17.6 9.5 10.7 1.4 15.6 7.2 291 17 260 165 -13.6 0 -13.6 -13.8 01/07/2007 21:00:00 13.1 1.7 17.6 8.8 13 1.7 16.8 8.4 11.1 1.8 16.8 6.1 287 17 287 165 -13.6 0 -13.6 -13.8 01/07/2007 21:10:00 11.2 1.4 15.3 7.6 11.2 1.4 15.3 7.2 9.4 1.3 13.7 5.7 285 15 291 165 -13.5 0 -13.4 -13.8 01/07/2007 21:20:00 11.1 1.3 14.1 8.4 10.9 1.3 14.1 8 9.4 1.1 12.6 6.5 293 17 297 165 -13.5 0 -13.2 -13.6 01/07/2007 21:30:00 12.6 1.7 16.4 9.1 12.4 1.7 16.1 9.1 11.5 2 16.1 6.8 300 15 305 165 -13.4 0 -13.2 -13.6 01/07/2007 21:40:00 11.3 1.4 14.1 8 11.1 1.3 13.7 8 10 1.9 14.1 6.1 296 15 312 165 -13.3 0 -13.2 -13.6 01/07/2007 21:50:00 13.1 1.7 19.1 8.8 12.9 1.7 19.5 8.8 12.5 1.8 19.1 8.4 308 11 319 165 -13.3 0 -13.2 -13.6 01/07/2007 22:00:00 14.7 2 19.1 8.8 14.5 2 18.7 8.8 14.1 2.1 18.3 8.8 305 12 305 165 -13.3 0 -13.2 -13.6 01/07/2007 22:10:00 14.7 1.7 19.1 10.3 14.5 1.7 18.7 10.3 13.5 1.9 18.7 8 297 15 292 165 -13.4 0 -13.2 -13.6 01/07/2007 22:20:00 13.2 2 17.2 8.8 13 2 16.8 8.4 12.5 2.3 17.9 7.2 303 16 291 165 -13.4 0 -13.2 -13.6 01/07/2007 22:30:00 14.4 1.5 19.1 11.1 14.2 1.5 18.7 11.1 13.6 1.5 17.9 9.5 305 11 319 165 -13.5 0 -13.2 -13.6 01/07/2007 22:40:00 18.2 1.7 21.4 13.3 18 1.7 21.4 13.3 18.1 1.8 22.9 13 313 9 322 165 -13.7 0 -13.6 -13.8 01/07/2007 22:50:00 16.2 1.5 20.2 12.2 16 1.5 20.2 11.8 16.1 1.6 19.9 11.8 316 9 311 165 -13.9 0.1 -13.6 -14 01/07/2007 23:00:00 16.5 1.6 20.2 12.2 16.4 1.6 20.2 11.5 16.3 1.7 20.2 11.1 314 10 316 165 -14.1 0 -14 -14.2 01/07/2007 23:10:00 15.4 1.5 18.7 10.3 15.2 1.5 18.3 10.3 15.3 1.5 19.9 11.1 315 12 310 165 -14.1 0 -13.8 -14.4 01/07/2007 23:20:00 14.7 1.7 18.7 9.5 14.5 1.8 18.7 9.5 14.2 2.1 19.1 8.8 309 13 336 165 -13.8 0 -13.6 -14 01/07/2007 23:30:00 12.4 1.5 15.3 7.2 12.2 1.5 15.6 6.8 10.9 1.9 15.6 6.8 300 17 328 165 -13.7 0 -13.6 -14 01/07/2007 23:40:00 11.7 1.5 16.1 7.2 11.6 1.5 16.1 6.8 9.8 1.3 14.9 6.5 290 19 283 165 -13.7 0 -13.6 -14 01/07/2007 23:50:00 14 1.6 17.6 9.5 13.9 1.6 17.6 9.9 11.3 1.7 16.4 7.2 287 18 254 165 -13.7 0 -13.6 -14 01/08/2007 00:00:00 12.7 2.2 18.3 8 12.5 2.1 18.3 8 11.8 2.1 16.4 6.8 303 16 307 165 -13.7 0 -13.6 -14 01/08/2007 00:10:00 13.4 1.5 16.8 9.1 13.2 1.5 16.8 9.5 12.7 1.3 15.6 8 311 10 312 165 -13.7 0 -13.4 -13.8 01/08/2007 00:20:00 11.1 1.7 16.1 8 11 1.6 16.1 7.6 10.3 1.5 14.9 6.8 308 14 296 165 -13.6 0 -13.4 -13.6 01/08/2007 00:30:00 14.1 1.2 17.2 11.1 13.9 1.3 17.2 10.7 12.8 1.4 16.1 9.5 304 11 313 165 -13.5 0 -13.4 -13.8 01/08/2007 00:40:00 14.8 1.3 17.9 10.7 14.6 1.3 17.2 10.7 14 1.7 17.6 9.5 307 11 306 165 -13.4 0 -13.2 -13.6 01/08/2007 00:50:00 13.4 1.3 17.2 9.9 13.2 1.3 16.8 9.9 12.5 1.4 16.1 8.8 304 10 281 165 -13.3 0 -13.2 -13.6 01/08/2007 01:00:00 13.3 1.5 17.2 8.4 13.1 1.5 17.2 8.4 12.3 1.7 16.8 6.5 304 13 313 165 -13.3 0 -13.2 -13.6 01/08/2007 01:10:00 13.8 1.6 17.6 9.1 13.7 1.6 17.6 8.8 13.5 1.8 17.6 9.1 308 9 295 165 -13.2 0 -13.2 -13.6 01/08/2007 01:20:00 12.6 1.2 15.3 8.8 12.4 1.2 15.3 8.8 12.3 1.2 16.1 9.1 310 8 313 165 -13.1 0 -13 -13.2 01/08/2007 01:30:00 12.1 1.5 15.6 9.1 12 1.5 15.6 9.1 10.9 1.4 14.9 7.6 304 12 290 165 -13.2 0 -13.2 -13.6 01/08/2007 01:40:00 13.2 1.5 16.4 9.1 13.1 1.5 16.4 9.1 11.1 1.6 15.3 7.6 296 14 303 165 -13.2 0 -13.2 -13.4 01/08/2007 01:50:00 13.1 1.5 16.4 9.9 13 1.5 16.4 9.9 11.2 1.5 16.1 8 294 15 301 165 -13.1 0 -13 -13.4 01/08/2007 02:00:00 12.5 1.5 15.3 8.4 12.4 1.5 15.3 8.4 10.3 1.6 15.3 6.8 295 15 302 165 -13 0 -12.6 -13.2 01/08/2007 02:10:00 12.2 1.1 16.1 9.5 12.1 1 16.1 8.8 10.3 1.5 15.6 7.2 292 16 289 165 -12.8 0 -12.6 -13 01/08/2007 02:20:00 12 1.5 15.6 9.1 11.9 1.4 15.6 8.8 10.3 2 15.3 6.5 294 15 300 165 -12.7 0 -12.6 -13.2 01/08/2007 02:30:00 15.6 1.7 20.6 11.5 15.4 1.7 20.2 11.1 14.8 2 20.6 9.1 304 13 307 165 -12.8 0 -12.6 -13 01/08/2007 02:40:00 16.6 1.7 21 12.2 16.4 1.7 20.6 12.2 16.4 2 21.4 10.7 310 9 319 165 -12.6 0 -12.4 -13 01/08/2007 02:50:00 16 1.7 21 11.1 15.9 1.8 20.6 11.5 15.6 1.7 20.6 11.5 309 10 305 165 -12.5 0 -12.2 -12.6 01/08/2007 03:00:00 18.3 1.7 22.1 13.3 18.2 1.7 21.8 13.7 17.2 1.7 21.8 11.8 303 10 291 165 -12.3 0 -12.2 -12.6 01/08/2007 03:10:00 16.1 1.4 20.2 12.2 15.9 1.4 20.2 12.2 15.9 1.6 19.9 11.5 314 9 313 165 -12.4 0 -12.2 -12.4 01/08/2007 03:20:00 15.3 1.5 18.3 11.5 15 1.5 18.3 11.1 15.1 1.6 18.7 10.7 315 7 309 165 -12.5 0 -12.4 -12.6 01/08/2007 03:30:00 16.6 1.7 21 11.8 16.5 1.7 21 11.8 16.6 1.7 20.6 11.8 314 7 320 165 -12.5 0 -12.4 -12.6 01/08/2007 03:40:00 18.6 1.2 21 14.1 18.4 1.3 21 14.1 18.6 1.4 21.8 14.9 316 6 317 165 -12.5 0 -12.4 -12.6 01/08/2007 03:50:00 17.5 1.6 21 12.6 17.4 1.6 20.6 13 17.5 1.7 21.4 12.6 315 7 316 165 -12.6 0 -12.4 -12.8 01/08/2007 04:00:00 14.7 1.8 18.7 9.9 14.6 1.8 18.7 9.5 14.4 1.9 19.5 9.1 315 9 304 165 -12.4 0 -12.4 -12.6 01/08/2007 04:10:00 15.8 2.1 20.6 11.5 15.6 2.1 20.6 9.1 14.9 2.2 19.9 9.9 312 15 303 165 -12.5 0 -12.4 -12.6 01/08/2007 04:20:00 17.3 1.3 21 14.1 17.1 1.3 20.6 13.7 16.3 1.7 21 12.2 309 11 309 165 -12.5 0 -12.2 -12.6 01/08/2007 04:30:00 19.1 1.4 22.6 15.3 18.9 1.5 22.6 14.5 18.9 1.7 22.6 13.7 313 10 309 165 -12.7 0.1 -12.6 -13 01/08/2007 04:40:00 18.3 1.6 22.1 13.7 18.1 1.5 22.1 13.3 18.3 1.7 22.9 13 314 9 316 165 -12.9 0 -12.6 -13 01/08/2007 04:50:00 21.3 2.2 25.2 15.3 21.1 2.2 25.2 15.3 21.3 2.4 26 15.3 315 9 316 165 -12.7 0.1 -12.6 -13.2 01/08/2007 05:00:00 18.3 2 23.3 13.7 18.1 1.9 22.9 13.7 18.1 2.2 23.3 13.3 313 9 311 165 -12.7 0 -12.4 -13 01/08/2007 05:10:00 18.4 1.7 22.6 14.1 18.2 1.7 22.6 13.7 17.8 2 22.6 13.3 308 10 312 165 -12.7 0 -12.4 -13 01/08/2007 05:20:00 19.8 2.3 25.2 14.9 19.7 2.3 24.8 15.3 19 2.4 24.8 13.3 306 11 307 165 -12.5 0 -12.4 -12.6 01/08/2007 05:30:00 21.2 1.7 26 17.6 21.1 1.7 26 17.2 20.5 1.8 25.6 15.6 306 10 288 165 -12.4 0 -12.2 -12.6 01/08/2007 05:40:00 21.4 1.7 25.6 16.1 21.3 1.7 25.6 15.6 21.2 1.7 25.6 14.9 312 10 306 165 -12.6 0 -12.4 -12.8 01/08/2007 05:50:00 22.5 1.8 27.1 17.9 22.4 1.8 27.1 18.3 22.1 1.8 26.8 18.3 310 9 309 165 -12.9 0 -12.6 -13 01/08/2007 06:00:00 26.3 1.5 29.1 19.9 26.1 1.5 29.1 19.5 25.6 2 29.4 18.3 303 9 287 165 -12.7 0 -12.6 -13 01/08/2007 06:10:00 26.8 1.3 29.8 22.6 26.6 1.3 29.8 22.1 26.2 1.7 29.8 21 303 9 302 165 -12.6 0 -12.4 -13 01/08/2007 06:20:00 22 1.9 27.5 18.3 21.8 1.9 27.1 17.9 21.2 1.9 27.1 16.4 306 9 305 165 -12.4 0 -12.2 -12.6 01/08/2007 06:30:00 22.7 2 27.1 17.9 22.5 2 26.8 17.2 21.1 1.9 26.3 16.1 303 9 305 165 -12.3 0.1 -12 -12.6 01/08/2007 06:40:00 21.2 2.3 26.3 16.1 21 2.3 26 16.1 20.2 2.2 26 14.9 304 11 301 165 -12.1 0 -12 -12.2 01/08/2007 06:50:00 19.7 2.4 26.3 14.9 19.5 2.4 26.8 13.3 19.2 2.7 26.8 12.2 312 12 310 165 -12.2 0 -12 -12.4 01/08/2007 07:00:00 22.2 2.5 28.3 14.9 22 2.5 27.9 15.3 21.7 2.8 29.1 13.7 311 10 292 165 -11.9 0.1 -11.8 -12.4 01/08/2007 07:10:00 20.2 2.9 27.1 12.6 20.1 2.9 27.5 12.2 19.5 3.3 27.1 10.3 312 13 324 165 -11.8 0 -11.8 -11.8 01/08/2007 07:20:00 17.6 2.6 23.7 9.9 17.7 2.6 23.3 9.9 15.6 2.7 22.9 8.4 304 15 284 165 -11.9 0 -11.6 -12.2 01/08/2007 07:30:00 21.7 2.3 27.5 15.3 21.7 2.3 27.5 14.9 20.6 2.9 27.5 12.6 308 9 316 165 -11.5 0.1 -11.2 -11.8 01/08/2007 07:40:00 24.5 1.9 27.9 17.6 24.3 1.9 27.9 17.9 24.5 2.2 29.4 17.6 315 7 312 165 -11.4 0 -11.2 -11.6 01/08/2007 07:50:00 26.4 1.6 30.6 21 26.2 1.6 30.2 21.4 26.5 1.7 30.9 21.4 312 6 310 165 -11.4 0 -11.2 -11.6 01/08/2007 08:00:00 26.9 1.7 30.2 22.1 26.7 1.7 29.8 22.1 27.1 1.9 31.8 19.9 311 6 311 165 -11.3 0 -11.2 -11.6 01/08/2007 08:10:00 25.9 1.9 30.2 19.9 25.7 1.9 29.8 19.5 25.9 2.3 30.9 18.3 312 6 312 165 -11.2 0 -11 -11.6 01/08/2007 08:20:00 21.4 2.4 27.5 14.9 21.3 2.4 27.1 14.9 21.4 2.5 27.9 14.5 316 10 307 165 -11.1 0 -11 -11.4 01/08/2007 08:30:00 22.7 1.9 26.8 16.1 22.5 1.9 26.3 16.4 22.3 2 27.9 13.7 312 6 310 165 -10.8 0 -10.6 -11.2 01/08/2007 08:40:00 23 2.2 26.8 15.6 22.8 2.1 26.3 15.6 22.9 2.2 27.5 14.9 315 6 309 165 -10.7 0 -10.6 -11 01/08/2007 08:50:00 21.3 2.3 26.3 14.9 21.1 2.3 26.3 14.9 21.2 2.5 27.5 14.1 316 7 308 165 -10.7 0.1 -10.6 -11 01/08/2007 09:00:00 19.8 2 24.4 14.5 19.5 2 24.4 14.5 19.8 2.2 24.4 13.3 319 9 313 165 -10.6 0 -10.4 -11 01/08/2007 09:10:00 16 2.4 22.1 9.1 15.9 2.4 22.6 9.9 15.7 2.5 23.3 7.6 318 10 315 165 -10.5 0 -10.4 -10.8 01/08/2007 09:20:00 15.2 1.5 19.5 11.5 15 1.5 19.5 11.1 14.9 1.5 19.5 11.5 316 11 316 165 -10.5 0 -10.4 -10.8 01/08/2007 09:30:00 15.2 1.7 19.1 10.3 15 1.7 19.1 9.9 14.5 1.7 19.1 10.7 314 11 310 165 -10.5 0 -10.4 -10.8 01/08/2007 09:40:00 16.8 1.9 21.4 11.8 16.6 1.9 21 11.8 16.4 1.9 21.4 11.1 314 9 316 165 -10.3 0.1 -10 -10.6 01/08/2007 09:50:00 17.5 2 22.9 11.5 17.3 2 22.9 11.5 17 2.1 22.6 11.1 314 9 310 165 -10 0 -9.7 -10.2 01/08/2007 10:00:00 18 2.3 22.9 11.5 17.8 2.3 22.9 11.8 17.4 2.8 23.7 10.3 310 13 312 165 -9.7 0 -9.5 -9.7 01/08/2007 10:10:00 19 2.3 24 13.3 18.8 2.3 23.7 13.3 17.9 2.4 23.7 12.2 309 9 314 165 -9.6 0 -9.3 -9.7 01/08/2007 10:20:00 19.4 1.9 24.4 14.9 19.2 1.9 23.7 14.5 17.9 2.1 24 11.1 305 10 307 165 -9.5 0 -9.3 -9.7 01/08/2007 10:30:00 19.5 1.9 26 14.1 19.3 1.9 25.6 14.5 18 2.2 24 12.2 305 10 305 165 -9.2 0.1 -9.1 -9.7 01/08/2007 10:40:00 17.8 1.6 22.1 13.7 17.6 1.6 21.8 13.7 16.4 2.2 22.9 9.9 305 12 302 165 -9 0 -8.9 -9.3 01/08/2007 10:50:00 16.9 1.7 21.4 12.2 16.7 1.7 21 12.2 16.3 2.1 21.8 10.3 307 13 319 165 -8.8 0 -8.5 -9.1 01/08/2007 11:00:00 17.2 1.9 22.9 13 17 1.9 22.6 13 16.7 2 22.1 12.6 313 9 310 165 -8.5 0 -8.3 -8.9 01/08/2007 11:10:00 19.7 1.6 24 16.1 19.5 1.6 24 15.6 18.5 2.1 23.3 12.6 307 9 310 165 -8.4 0 -8.1 -8.7 01/08/2007 11:20:00 21.7 1.8 26.3 16.8 21.6 1.8 26.8 16.8 20.5 2.1 26.3 14.9 304 9 305 165 -8.3 0 -8.1 -8.5 01/08/2007 11:30:00 21.6 1.7 28.3 17.6 21.4 1.7 27.9 17.2 20.5 2 26 14.9 306 9 302 165 -8.2 0 -8.1 -8.3 01/08/2007 11:40:00 21 1.7 26 16.8 20.8 1.7 26.3 16.8 19.2 2.2 26.3 13.7 304 10 302 165 -8.1 0 -7.9 -8.5 01/08/2007 11:50:00 21.3 2.2 26 16.1 21.1 2.2 25.6 16.1 20.3 2.5 25.6 12.6 305 10 308 165 -8 0 -7.6 -8.1 01/08/2007 12:00:00 21 1.8 25.2 16.1 20.9 1.7 25.2 16.4 19.8 2.2 26 12.6 306 9 307 165 -7.9 0 -7.6 -8.1 01/08/2007 12:10:00 20.2 1.7 25.2 14.9 20 1.7 24.4 14.5 19.1 1.9 23.7 13.7 306 8 294 165 -7.8 0 -7.6 -8.1 01/08/2007 12:20:00 20.9 1.6 24.4 16.4 20.7 1.6 24 16.4 19.1 1.9 24.4 13.7 305 7 296 165 -7.9 0 -7.6 -8.1 01/08/2007 12:30:00 20 1.5 23.7 14.9 19.8 1.5 23.3 14.1 18.2 2.2 22.6 11.8 305 9 295 165 -7.7 0 -7.4 -7.9 01/08/2007 12:40:00 18.6 1.5 22.6 14.5 18.4 1.5 22.1 14.5 17.2 1.9 22.6 12.2 307 8 307 165 -7.5 0 -7.4 -7.9 01/08/2007 12:50:00 17.9 1.3 21.4 14.9 17.7 1.3 21.4 14.1 16.7 1.6 21.4 11.5 308 8 285 165 -7.4 0 -7.2 -7.6 01/08/2007 13:00:00 17.9 1.3 21.4 14.5 17.7 1.3 21 14.9 16.8 1.7 21.8 11.5 309 8 308 165 -7.3 0 -7.2 -7.6 01/08/2007 13:10:00 16.9 1.4 21.8 13 16.7 1.3 21 13 15.5 1.8 21 10.7 305 13 258 165 -7.1 0.1 -6.8 -7.4 01/08/2007 13:20:00 16.5 1.3 20.6 13 16.3 1.3 20.2 13 15.6 1.6 20.2 11.8 310 9 310 165 -7.1 0 -6.8 -7.2 01/08/2007 13:30:00 16.9 1.5 21.4 13 16.7 1.5 21.4 13 16.2 1.7 21.4 11.5 311 9 318 165 -7 0 -6.8 -7.2 01/08/2007 13:40:00 18.2 1.5 22.1 14.9 17.9 1.5 21.8 14.5 17.9 1.7 22.6 12.2 312 7 316 165 -6.9 0 -6.6 -7 01/08/2007 13:50:00 17.7 1.4 22.1 14.5 17.5 1.4 21.8 14.1 16.3 1.7 21.4 11.8 309 8 301 165 -6.8 0 -6.6 -6.8 01/08/2007 14:00:00 17.2 1.7 21.8 13 17 1.7 21.4 13 16.2 1.8 21 11.5 309 9 308 165 -6.7 0 -6.6 -6.8 01/08/2007 14:10:00 16 1.6 20.2 11.8 15.7 1.6 19.9 11.5 15.3 1.9 20.2 9.9 314 7 312 165 -6.5 0 -6.4 -6.8 01/08/2007 14:20:00 15.2 1.5 19.1 11.1 14.9 1.5 19.1 11.1 14.4 1.4 17.9 10.7 313 11 308 165 -6.4 0 -6.1 -6.6 01/08/2007 14:30:00 15.5 1.5 19.5 11.5 15.3 1.5 19.1 11.1 14.9 1.6 19.9 8.8 315 10 315 165 -6.4 0.1 -6.1 -6.6 01/08/2007 14:40:00 17.4 1.6 21 12.6 17.2 1.7 21.4 11.8 17 1.7 21.8 12.6 314 8 310 165 -6.5 0 -6.1 -6.8 01/08/2007 14:50:00 16 2.3 22.1 9.5 15.8 2.3 21.8 9.5 15.4 2.2 21.4 10.3 316 12 303 165 -6.7 0 -6.6 -6.8 01/08/2007 15:00:00 16.1 1.7 20.2 11.1 15.9 1.7 19.9 11.5 15.7 1.7 19.5 11.1 319 9 300 165 -6.8 0 -6.6 -7 01/08/2007 15:10:00 14.5 1.7 19.1 10.3 14.3 1.7 18.7 10.7 14.1 1.7 18.3 10.3 316 10 314 165 -6.9 0 -6.6 -7 01/08/2007 15:20:00 14 1.7 19.1 10.3 13.8 1.7 19.1 9.5 13.2 1.7 19.1 8.8 313 11 312 165 -6.9 0 -6.8 -7 01/08/2007 15:30:00 11.9 1.3 15.3 8 11.6 1.5 15.6 6.8 11.6 1.4 15.3 7.6 327 16 316 165 -7.1 0 -6.8 -7.2 01/08/2007 15:40:00 12.5 1.3 16.8 8.8 12.3 1.3 16.4 8.8 12 1.4 16.8 8.4 317 13 315 165 -6.9 0.1 -6.6 -7.2 01/08/2007 15:50:00 14.1 2.2 19.5 7.6 13.9 2.2 19.5 7.6 13.5 2.4 21.8 8 316 12 325 165 -6.7 0 -6.6 -6.8 01/08/2007 16:00:00 16.3 2.2 22.1 11.5 16.1 2.2 21.8 11.5 15.8 2.2 20.6 10.7 316 14 300 165 -6.5 0 -6.4 -6.8 01/08/2007 16:10:00 18.7 3.1 25.6 12.6 18.5 2.9 25.6 12.6 18 3.1 25.2 11.1 317 13 310 165 -6.7 0 -6.6 -6.8 01/08/2007 16:20:00 19.1 2.1 25.6 13.7 18.9 2.1 25.2 13.3 18.9 2.2 24.4 13 319 10 316 165 -6.8 0 -6.6 -6.8 01/08/2007 16:30:00 20.7 2.4 26.3 13.7 20.6 2.4 27.1 13 20.2 2.7 27.9 13.7 316 11 298 165 -6.5 0 -6.4 -6.8 01/08/2007 16:40:00 20.4 2.2 26 15.6 20.2 2.2 26 15.6 20.2 2.4 26.8 14.5 320 12 313 165 -6.5 0 -6.4 -6.8 01/08/2007 16:50:00 18.1 2.3 24 12.2 18 2.4 24 12.2 17.6 2.6 25.2 11.8 317 13 322 165 -6.5 0 -6.1 -6.8 01/08/2007 17:00:00 15.5 2.1 20.6 9.9 15.2 2.1 20.2 9.1 14.8 2.1 20.6 9.1 327 18 350 165 -6.8 0.1 -6.6 -7 01/08/2007 17:10:00 12 1.7 17.2 5.3 11.8 1.8 16.4 5.3 11.6 1.6 15.6 6.5 329 15 347 165 -7 0 -6.8 -7.2 01/08/2007 17:20:00 12.7 2.7 20.2 5.7 12.4 2.6 19.1 6.1 12 2.5 19.1 4.9 329 17 341 165 -7.3 0 -7 -7.4 01/08/2007 17:30:00 15.3 2.2 21.8 11.1 14.9 2.4 21.8 8.8 14.6 2.5 21.4 8.8 327 21 350 165 -7.3 0 -7.2 -7.4 01/08/2007 17:40:00 15 2.3 21 9.5 14.8 2.4 20.6 8 14.2 2.2 20.6 8.4 321 21 295 165 -7.4 0.1 -7.2 -7.6 01/08/2007 17:50:00 14 2.5 19.9 9.5 13.8 2.5 19.9 8.8 13.4 2.3 19.9 8.8 317 11 313 165 -7.2 0.1 -6.8 -7.6 01/08/2007 18:00:00 13.7 1.8 18.7 8.4 13.6 1.8 18.3 8.8 13.1 2.1 19.9 6.5 319 12 324 165 -7.2 0 -7 -7.2 01/08/2007 18:10:00 14.9 2.1 21 10.3 14.8 2.1 20.2 9.1 14.3 2.2 20.6 9.5 321 14 336 165 -7.2 0 -7 -7.4 01/08/2007 18:20:00 15.2 2.5 23.3 8.8 15.1 2.5 22.9 8 14.8 2.7 22.6 8.4 323 12 328 165 -7.2 0 -6.8 -7.4 01/08/2007 18:30:00 14.3 2.6 21.8 7.2 14.2 2.5 21 6.8 13.5 2.7 19.5 6.8 318 12 316 165 -7.1 0 -6.8 -7.4 01/08/2007 18:40:00 10.5 1.7 15.3 6.1 10.4 1.8 16.1 6.1 9.5 1.9 15.3 4.9 319 15 318 165 -7.3 0.1 -6.8 -7.6 01/08/2007 18:50:00 9.9 1.5 15.6 5.7 9.4 1.6 14.1 5.3 8.9 1.8 13.7 4.2 334 17 359 165 -7.5 0 -7.2 -7.6 01/08/2007 19:00:00 10.4 1.3 15.3 6.8 10.4 1.3 15.3 6.8 9.6 1.5 14.1 5.7 317 11 325 165 -7.7 0.1 -7.2 -8.1 01/08/2007 19:10:00 10.3 1.9 16.4 6.1 10.1 2 16.4 6.1 9.4 1.8 16.1 5.3 326 14 304 165 -7.4 0.1 -7 -7.6 01/08/2007 19:20:00 11.9 1.6 16.4 6.8 11.7 1.7 15.6 6.8 11.5 1.7 16.4 6.8 333 15 351 165 -7.7 0 -7.4 -8.1 01/08/2007 19:30:00 10.6 1.5 14.9 7.6 10.2 1.7 15.3 5.3 10.5 1.5 14.5 6.8 337 11 345 165 -7.8 0 -7.6 -8.1 01/08/2007 19:40:00 11.9 1.8 16.8 8 11.7 2 17.2 5.3 12 2 17.6 8 335 11 340 165 -7.8 0 -7.4 -8.1 01/08/2007 19:50:00 12.9 1.8 19.9 8.8 12.6 2.1 19.9 6.1 12.7 1.7 18.7 8.4 334 13 337 165 -7.9 0 -7.6 -8.1 01/08/2007 20:00:00 9.5 1.2 11.8 6.5 7.9 1.5 11.1 4.9 9.1 1.3 12.2 5.7 348 10 355 165 -8.7 0.4 -7.9 -9.3 01/08/2007 20:10:00 11.5 1.1 14.9 8.4 10.6 1.7 14.9 6.5 11 1.1 13.3 7.6 346 7 338 165 -9.3 0 -9.1 -9.3 01/08/2007 20:20:00 11.2 1.3 15.3 6.5 11 1.5 16.4 5.7 10.8 1.3 14.5 7.2 339 10 345 165 -9.4 0 -9.1 -9.7 01/08/2007 20:30:00 12 1.2 14.9 8.8 11.7 1.7 15.3 5.3 11.8 1.2 14.5 8.4 339 10 341 165 -9.4 0 -9.1 -9.7 01/08/2007 20:40:00 12.2 1.3 16.4 8.8 12.1 1.3 16.4 8.8 11.7 1.3 15.6 8 334 9 330 165 -9.4 0 -9.1 -9.7 01/08/2007 20:50:00 11.6 1.1 14.9 9.1 11.5 1 14.9 9.1 11.3 1 14.9 9.1 333 7 338 165 -9.3 0 -9.1 -9.5 01/08/2007 21:00:00 13.6 1.5 19.5 9.9 13.6 1.6 19.5 9.5 13.4 1.6 18.7 9.5 334 9 340 165 -9.1 0.1 -8.7 -9.5 01/08/2007 21:10:00 14 1.6 19.9 10.7 13.8 1.7 19.5 10.3 13.8 1.6 19.5 9.1 338 11 340 165 -8.9 0 -8.5 -9.1 01/08/2007 21:20:00 13.9 1.5 18.3 10.3 13.5 1.7 18.7 9.9 13.4 1.5 19.1 9.5 335 9 338 165 -9.2 0 -8.9 -9.5 01/08/2007 21:30:00 14.1 1.6 17.6 10.7 14 1.7 17.9 9.9 13.7 1.7 17.9 9.1 334 9 334 165 -9.5 0 -9.3 -9.7 01/08/2007 21:40:00 14.3 1.9 21.8 9.5 14.1 2.3 21 8.4 13.2 2.2 19.1 5.7 342 7 341 165 -9.5 0 -9.3 -9.7 01/08/2007 21:50:00 13.5 1.7 17.2 9.1 13.3 1.8 17.6 8.8 12.5 1.7 16.8 6.8 341 8 344 165 -9.3 0.1 -9.1 -9.7 01/08/2007 22:00:00 12.5 1.8 17.2 7.6 12.3 1.9 17.2 6.8 11.6 1.7 15.6 6.8 340 9 333 165 -9.3 0 -9.1 -9.5 01/08/2007 22:10:00 13.1 1.5 16.4 8 13.1 1.6 16.4 8.4 12.1 1.7 15.6 8 337 7 339 165 -9.5 0.1 -9.3 -9.7 01/08/2007 22:20:00 12.8 1.3 16.8 9.5 12.6 1.6 16.8 6.8 12.2 1.4 16.8 8 340 8 345 165 -9.6 0 -9.3 -9.7 01/08/2007 22:30:00 14 1.7 19.5 9.1 13.9 1.7 18.7 9.1 13.9 1.8 18.7 9.5 335 9 349 165 -9.7 0 -9.5 -10 01/08/2007 22:40:00 12.9 2.2 18.7 8 12.9 2.4 19.1 8 12.7 2.3 18.3 7.6 336 8 340 165 -9.8 0 -9.7 -10 01/08/2007 22:50:00 10.8 2.2 17.6 6.5 10.4 2.3 16.1 5.3 10.8 2.2 16.4 6.5 339 11 348 165 -9.8 0 -9.5 -10 01/08/2007 23:00:00 7.9 1.6 13 5.3 7.2 1.8 13 3.8 7.8 1.6 13 4.9 344 10 349 165 -10.2 0.2 -9.7 -10.6 01/08/2007 23:10:00 10.8 1.5 15.6 8 10.1 1.9 14.9 5.3 10.7 1.6 14.9 6.8 343 11 349 165 -10.1 0.1 -9.7 -10.6 01/08/2007 23:20:00 12.1 1.1 15.3 9.1 11.8 1.7 16.4 4.9 12 1.2 16.1 8.8 343 7 331 165 -10.3 0 -10.2 -10.6 01/08/2007 23:30:00 11.7 1.1 15.3 8.8 11.6 1.2 15.3 7.2 11.5 1.2 14.9 7.6 338 8 333 165 -10.4 0 -10.2 -10.6 01/08/2007 23:40:00 14.5 1.1 17.2 11.5 14.5 1.1 17.9 11.1 14.2 1.1 16.8 9.9 338 6 344 165 -10.4 0 -10.2 -10.6 01/08/2007 23:50:00 15.4 1.4 19.5 11.8 15.2 1.9 19.9 8.4 15.4 1.3 18.7 12.2 340 8 332 165 -10.3 0 -10.2 -10.6 01/09/2007 00:00:00 14.4 2 18.3 8 14.1 2.2 19.1 7.2 13.8 2.2 18.3 7.6 337 9 337 165 -10.2 0 -10.2 -10.4 01/09/2007 00:10:00 12 1.7 17.6 6.5 11.2 1.9 17.9 6.5 11.3 1.8 17.2 5.3 342 11 354 165 -10.2 0 -10 -10.4 01/09/2007 00:20:00 12.2 1.6 16.4 8 11.7 1.7 16.4 7.6 11.7 1.6 15.3 8 341 10 353 165 -10.2 0 -10 -10.4 01/09/2007 00:30:00 13.4 1.3 16.8 10.3 13.3 1.3 16.4 9.9 13.1 1.3 17.6 10.3 334 11 317 165 -10.1 0.1 -9.7 -10.2 01/09/2007 00:40:00 12.6 1.2 15.6 9.1 12.4 1.2 15.6 9.1 12.3 1.4 15.6 8.4 323 10 319 165 -10.1 0 -9.7 -10.4 01/09/2007 00:50:00 11.1 1.2 13.7 6.8 10.9 1.3 14.1 6.8 10.7 1.2 13.7 6.5 326 10 323 165 -10 0 -9.7 -10.2 01/09/2007 01:00:00 12.3 1.5 15.6 8.4 12.1 1.4 15.3 8.8 11.4 1.4 14.9 7.6 313 12 300 165 -9.7 0.1 -9.3 -10 01/09/2007 01:10:00 11.9 2.2 16.8 6.1 11.8 2.1 16.8 6.1 10.5 2.4 15.3 4.2 306 9 299 165 -9.5 0.1 -9.3 -9.7 01/09/2007 01:20:00 10.9 1.8 14.5 5.3 10.9 1.9 14.9 5.3 9.7 1.7 13.7 4.6 310 15 305 165 -9.7 0 -9.3 -10 01/09/2007 01:30:00 11.1 1.4 14.1 7.2 11 1.5 14.5 7.6 10 1.5 13.7 6.5 325 15 351 165 -9.4 0 -9.3 -9.7 01/09/2007 01:40:00 8.9 1.9 14.5 4.9 8.6 2 13.3 4.6 7.5 2.3 12.2 1.5 334 15 340 165 -9.5 0 -9.3 -9.7 01/09/2007 01:50:00 7.4 1.8 12.6 2.3 7.1 1.8 12.6 1.1 5.9 1.9 12.6 1.9 335 17 335 165 -9.4 0 -9.1 -9.7 01/09/2007 02:00:00 6.6 1.2 10.7 2.6 6.3 1.3 10.3 2.3 6 1.3 9.9 2.3 330 17 318 165 -9.4 0.1 -9.1 -9.7 01/09/2007 02:10:00 8.3 1.3 11.5 4.9 8 1.5 11.1 4.6 7.7 1.4 11.5 4.2 329 16 353 165 -9.4 0 -9.3 -9.7 01/09/2007 02:20:00 9.7 1.9 14.5 4.6 9.2 1.9 14.9 4.6 9 1.8 13.7 5.7 339 13 357 165 -9 0.1 -8.7 -9.3 01/09/2007 02:30:00 8.6 1.6 13.7 5.3 8.5 1.6 13.3 4.9 7.6 1.6 11.8 4.2 324 17 350 165 -9 0.1 -8.9 -9.3 01/09/2007 02:40:00 8.2 1.5 11.8 3 8.1 1.5 11.8 2.6 7.4 1.4 10.7 2.6 313 20 309 165 -9.4 0 -9.1 -9.7 01/09/2007 02:50:00 7.5 1.6 11.5 3.8 7.3 1.7 11.5 1.9 6.3 1.7 10.3 1.5 316 19 332 165 -9.3 0.1 -9.1 -9.7 01/09/2007 03:00:00 8.8 2.5 14.9 2.3 8.2 2.3 15.3 2.3 7.8 2.3 15.3 2.6 331 20 341 165 -9.3 0.3 -8.5 -9.7 01/09/2007 03:10:00 7.4 1.7 11.1 1.5 7 1.8 11.1 1.5 6.1 2.2 11.1 0.4 334 23 318 165 -8.9 0.2 -8.5 -9.1 01/09/2007 03:20:00 3.5 1.8 9.1 0.4 3.4 1.8 9.1 0.4 3.3 1.4 8 0.4 275 47 293 165 -9.1 0.1 -8.7 -9.3 01/09/2007 03:30:00 3.6 2.4 9.9 0.4 3.4 2.4 9.9 0.4 2.9 1.7 8.4 0.4 197 102 304 165 -9 0.2 -8.5 -9.3 01/09/2007 03:40:00 3.7 2.2 9.5 0.4 3.6 2.3 9.5 0.4 3.2 1.7 6.8 0.4 305 94 250 165 -9.2 0 -8.9 -9.5 01/09/2007 03:50:00 2.9 2.3 9.9 0.4 2.7 2.4 9.9 0.4 2.3 1.6 8.4 0.4 356 90 287 165 -9.6 0.1 -9.3 -9.7 01/09/2007 04:00:00 2.1 0.9 3.8 0.4 2 0.8 3.8 0.4 2.3 0.7 3.8 0.7 122 20 138 165 -9.7 0 -9.5 -10 01/09/2007 04:10:00 2.5 1.5 7.2 0.4 2.4 1.5 7.6 0.4 2.4 1.3 7.6 0.4 206 94 311 165 -9.6 0.1 -9.3 -10 01/09/2007 04:20:00 3.3 2 8.8 0.4 3.2 1.8 8.4 0.4 3.1 1.6 7.6 0.4 269 38 329 165 -9.1 0.3 -8.5 -9.7 01/09/2007 04:30:00 1.5 0.8 4.2 0.4 1.4 0.9 4.2 0.4 1.7 0.7 3.4 0.4 179 56 242 165 -9.1 0.1 -8.7 -9.3 01/09/2007 04:40:00 2 1.1 6.8 0.4 1.8 1 6.5 0.4 2 1 5.3 0.4 170 72 349 165 -9.1 0.1 -8.7 -9.3 01/09/2007 04:50:00 1.6 0.9 4.2 0.4 1.5 0.9 4.6 0.4 1.8 0.8 4.9 0.4 147 45 104 165 -8.8 0.2 -8.5 -9.1 01/09/2007 05:00:00 1.8 0.8 4.6 0.4 1.7 0.8 4.2 0.4 2 0.7 3.8 0.4 170 38 272 165 -8.9 0 -8.5 -9.1 01/09/2007 05:10:00 2.2 1.3 6.1 0.4 2.1 1.5 7.2 0.4 2.2 1.3 6.5 0.4 173 64 268 165 -8.9 0 -8.7 -9.1 01/09/2007 05:20:00 2.9 2.1 6.8 0.4 2.8 2.1 6.8 0.4 2.6 1.8 7.2 0.4 321 94 278 165 -8.8 0.1 -8.3 -9.1 01/09/2007 05:30:00 5.6 1.5 9.5 1.1 5.7 1.4 9.5 1.5 5.2 1.7 9.5 0.4 285 18 276 165 -8.4 0 -8.1 -8.5 01/09/2007 05:40:00 4.1 2 9.5 0.7 4.1 2.1 9.5 0.4 4.1 1.9 10.3 0.7 288 22 301 165 -8.2 0 -8.1 -8.5 01/09/2007 05:50:00 6.5 1.2 9.5 3.4 6.4 1.2 9.1 3.4 5.8 1.2 9.5 3 289 11 300 165 -8.2 0 -8.1 -8.5 01/09/2007 06:00:00 5.3 1.4 9.1 3 5.1 1.5 9.1 2.6 4.7 1.2 8 2.3 307 20 291 165 -8.1 0.1 -7.6 -8.3 01/09/2007 06:10:00 3.1 0.8 5.3 1.5 2.9 0.8 5.3 1.1 2.9 0.8 5.3 1.1 301 22 343 165 -8.1 0 -7.6 -8.5 01/09/2007 06:20:00 3.6 1.7 8.4 0.4 3.6 1.7 8.8 0.4 3.2 1.7 8 0.4 286 20 278 165 -8.1 0 -8.1 -8.3 01/09/2007 06:30:00 7.3 2.1 12.6 3.8 7.2 2.1 12.6 3.8 6.6 1.8 11.8 2.6 287 13 289 165 -7.9 0 -7.6 -8.1 01/09/2007 06:40:00 9.7 1.5 13.7 4.9 9.6 1.5 13.3 4.6 8.2 1.8 14.1 4.2 291 12 291 165 -7.9 0 -7.6 -8.1 01/09/2007 06:50:00 10.8 1.7 14.5 6.8 10.6 1.7 14.9 6.5 9 2 14.9 4.9 291 11 282 165 -7.8 0.1 -7.4 -8.1 01/09/2007 07:00:00 9.9 1.7 13.3 6.1 9.7 1.7 13 6.1 8.4 1.7 13.3 4.6 299 13 299 165 -7.6 0 -7.4 -8.1 01/09/2007 07:10:00 10.6 1.3 13.3 7.2 10.4 1.3 13.7 7.2 8.4 1.3 11.5 5.3 297 11 301 165 -7.9 0.1 -7.4 -8.1 01/09/2007 07:20:00 8.7 1.7 13 4.9 8.6 1.6 13.3 4.9 7.3 1.5 13 3.8 298 13 288 165 -7.5 0 -7.2 -7.6 01/09/2007 07:30:00 7.1 1.8 12.6 3.8 6.9 1.8 12.2 3.8 5.9 1.3 9.9 3.8 298 12 293 165 -7.7 0.1 -7.4 -8.1 01/09/2007 07:40:00 9 1.2 11.5 5.7 8.9 1.2 11.8 6.1 7.3 1.1 10.3 4.9 293 10 288 165 -8.1 0.2 -7.6 -8.5 01/09/2007 07:50:00 11.2 1.2 14.1 8.8 11 1.1 13.7 8.4 9 1.5 13 6.5 301 10 313 165 -8.4 0.1 -8.1 -8.5 01/09/2007 08:00:00 10.9 1.2 14.1 7.6 10.7 1.2 13.7 7.6 9.2 1.5 13.3 4.9 306 8 312 165 -7.9 0 -7.6 -8.3 01/09/2007 08:10:00 9 1.8 14.1 4.6 8.9 1.8 13.7 4.9 7.3 1.5 12.2 4.6 300 11 293 165 -7.6 0 -7.2 -8.1 01/09/2007 08:20:00 8.1 1.4 12.2 4.6 8.2 1.4 12.2 4.2 7.3 1.5 11.1 3.8 282 10 273 165 -7.8 0 -7.6 -8.1 01/09/2007 08:30:00 12 1.3 14.9 7.6 12 1.3 14.9 7.6 9.7 1.4 13 6.5 289 8 295 165 -7.6 0.1 -7.2 -8.1 01/09/2007 08:40:00 11.9 0.7 14.1 10.3 11.8 0.7 14.1 9.9 8.4 0.9 11.8 6.8 294 6 298 165 -7.8 0 -7.6 -8.1 01/09/2007 08:50:00 11.4 0.8 14.1 9.5 11.3 0.8 14.1 8.8 8.3 1 11.1 6.1 294 6 291 165 -7.7 0 -7.6 -7.9 01/09/2007 09:00:00 10.6 0.8 13.3 8.8 10.5 0.8 13.3 8.8 7.9 1 11.8 5.3 294 9 298 165 -7.6 0.1 -7.2 -8.1 01/09/2007 09:10:00 10.5 0.7 12.6 8.8 10.4 0.6 12.2 8.4 7.6 0.9 10.3 5.3 294 7 296 165 -7.6 0 -7.2 -7.6 01/09/2007 09:20:00 10.6 1 12.6 6.8 10.4 1 12.6 6.5 8.2 1 10.3 4.9 299 8 294 165 -7.6 0.2 -7.2 -8.1 01/09/2007 09:30:00 7.5 1.8 11.1 3.8 7.3 1.9 11.1 3 6.4 1.3 9.5 3.4 315 19 302 165 -8.2 0.3 -7.6 -8.7 01/09/2007 09:40:00 5.7 1 8.8 3.4 5.6 0.9 9.1 3.4 5.4 0.8 8 3.4 329 14 316 165 -9.2 0.2 -8.7 -9.5 01/09/2007 09:50:00 7.2 1.5 10.7 3.8 7.1 1.4 10.7 3.4 6.6 1.3 10.7 3.8 313 15 310 165 -8.5 0.4 -8.1 -9.3 01/09/2007 10:00:00 5.4 1.1 9.1 3 5.3 1.2 8.8 2.3 5.2 1.1 7.6 1.9 316 17 322 165 -8.1 0 -7.9 -8.5 01/09/2007 10:10:00 8 1.2 11.1 4.6 7.8 1.2 10.7 4.9 6.4 1.1 9.1 1.5 298 11 300 165 -7.5 0.3 -6.8 -8.1 01/09/2007 10:20:00 4.9 1.1 7.6 1.5 4.8 1.1 8 1.5 4.4 1.1 7.6 1.9 308 20 279 165 -7 0 -6.8 -7.2 01/09/2007 10:30:00 4.8 1.2 8 2.6 4.7 1.2 8 2.6 4 0.9 7.2 2.3 305 15 323 165 -6.8 0 -6.6 -7.2 01/09/2007 10:40:00 5.7 1.8 9.5 2.3 5.6 1.8 9.1 2.3 4.7 1.3 9.1 1.9 306 19 292 165 -6.8 0.1 -6.6 -7 01/09/2007 10:50:00 8.1 0.9 10.3 5.3 8 0.9 10.3 5.3 6.5 1.1 9.9 4.2 292 9 301 165 -7.2 0.1 -6.6 -7.4 01/09/2007 11:00:00 8.3 1 10.7 5.7 8.2 1 10.7 5.7 6.4 0.8 8.8 4.2 298 8 294 165 -7.2 0 -7 -7.4 01/09/2007 11:10:00 8.8 1.1 10.3 4.6 8.7 1.1 10.3 4.9 6.9 0.8 8.8 4.6 300 9 290 165 -7 0.1 -6.6 -7.4 01/09/2007 11:20:00 8.5 1 10.3 5.3 8.3 1 9.9 5.3 7.1 0.9 9.1 4.6 305 11 299 165 -6.6 0.1 -6.1 -6.8 01/09/2007 11:30:00 4.9 1.7 8.4 1.5 4.7 1.7 8.8 1.1 4.3 1.2 8 1.9 317 20 302 165 -5.9 0.2 -5.5 -6.6 01/09/2007 11:40:00 4.6 1 8.4 1.9 4.5 1.1 8.4 1.9 4.2 0.8 6.5 2.6 313 20 301 165 -5.6 0.2 -5.3 -6.1 01/09/2007 11:50:00 6.1 0.8 8.4 4.2 6 0.9 8.4 3.8 5.2 0.7 7.6 3.4 304 10 309 165 -6.1 0 -5.7 -6.4 01/09/2007 12:00:00 7.4 0.9 9.1 4.9 7.3 0.9 9.5 5.3 6.2 1.1 8.8 4.2 307 7 306 165 -6.1 0 -5.9 -6.6 01/09/2007 12:10:00 5.8 1.3 8.8 3 5.7 1.2 8.8 3 5.3 1.2 8.4 3 310 10 313 165 -5.5 0.2 -5 -6.1 01/09/2007 12:20:00 4.1 1 6.5 1.9 3.9 1 6.5 1.9 3.8 0.9 6.5 1.5 321 18 317 165 -4.9 0.3 -4.4 -5.5 01/09/2007 12:30:00 4.6 0.8 6.8 2.6 4.5 0.8 6.8 2.3 4.4 0.8 6.5 2.6 318 20 307 165 -4.8 0.2 -4.4 -5.3 01/09/2007 12:40:00 4.7 1 7.6 2.6 4.6 1 7.6 2.6 4.5 1 7.2 2.3 319 13 328 165 -5 0.1 -4.6 -5.5 01/09/2007 12:50:00 4 1 6.5 1.1 3.6 1.2 6.5 1.1 3.9 0.9 6.1 1.5 344 19 309 165 -5 0.3 -4.6 -5.5 01/09/2007 13:00:00 4.6 0.9 7.2 2.6 4.6 0.9 7.6 2.3 4.4 1 6.8 2.3 321 19 338 165 -4.7 0 -4.6 -5 01/09/2007 13:10:00 6.5 1.3 9.5 3.4 6.4 1.3 9.5 3 5.6 1 8.4 3.4 307 11 308 165 -5.4 0.1 -5 -5.7 01/09/2007 13:20:00 5.6 0.6 6.8 3.8 5.5 0.6 7.2 3.4 4.7 0.6 6.1 3 308 8 308 165 -5.4 0.1 -5 -5.7 01/09/2007 13:30:00 5.7 1 8.4 2.6 5.7 1 8.4 2.6 5 0.9 7.6 1.5 307 10 304 165 -5.2 0.1 -4.8 -5.7 01/09/2007 13:40:00 4.6 0.9 7.2 2.6 4.6 0.9 7.2 2.3 4 0.9 6.8 1.9 300 12 302 165 -5.2 0.2 -4.6 -5.5 01/09/2007 13:50:00 3.9 0.7 5.7 1.9 3.9 0.7 5.7 2.3 3.5 0.6 5.3 1.9 311 11 330 165 -5.2 0.1 -4.8 -5.5 01/09/2007 14:00:00 3.9 0.6 4.9 1.9 3.8 0.6 4.9 1.9 4.1 0.6 5.3 1.9 22 22 16 165 -5.8 0.5 -4.8 -6.6 01/09/2007 14:10:00 3.9 0.7 5.3 2.3 3.8 0.7 5.3 2.3 4.2 0.7 5.7 2.6 27 9 25 165 -6 0.3 -5.5 -6.6 01/09/2007 14:20:00 3.6 0.5 5.3 2.3 2.6 0.8 4.9 1.1 3.7 0.5 5.3 2.3 4 11 356 165 -6 0.3 -5.5 -6.6 01/09/2007 14:30:00 3.3 0.6 4.9 2.3 3.1 0.6 4.9 1.5 3.3 0.6 4.9 1.9 352 21 353 165 -5.5 0.1 -5.3 -5.7 01/09/2007 14:40:00 3.3 0.6 4.9 1.9 2.8 0.7 4.6 1.1 3.4 0.6 4.9 2.3 347 11 348 165 -5.5 0.1 -5.3 -5.7 01/09/2007 14:50:00 4.5 0.6 6.1 2.3 4 0.9 6.1 1.9 4.4 0.6 5.7 3 342 13 330 165 -6 0 -5.7 -6.1 01/09/2007 15:00:00 4.1 0.5 5.7 3 4 0.5 5.3 3 4.1 0.5 5.7 2.6 327 10 305 165 -5.8 0 -5.5 -6.1 01/09/2007 15:10:00 4.4 0.7 6.1 2.3 4.3 0.8 6.1 1.9 4.4 0.6 5.7 2.6 332 12 338 165 -5.6 0.1 -5.5 -5.9 01/09/2007 15:20:00 5.3 1.3 8.4 3.4 5.3 1.3 8.4 2.6 5 1 8.4 2.6 322 15 300 165 -6.2 0.2 -5.7 -6.6 01/09/2007 15:30:00 7.5 0.6 8.8 5.7 7.5 0.6 8.8 5.7 6.3 0.7 8.4 4.2 306 6 303 165 -6.6 0 -6.4 -6.8 01/09/2007 15:40:00 7.1 0.9 8.4 4.2 7 0.9 8.4 3.8 6.2 0.6 8 4.6 309 8 301 165 -6.5 0.1 -6.1 -6.8 01/09/2007 15:50:00 5.3 0.7 7.2 3.4 5.2 0.7 6.8 3.4 5.3 0.7 7.2 3 321 11 328 165 -6.5 0 -6.1 -6.6 01/09/2007 16:00:00 4.3 0.8 6.1 2.3 4.2 0.9 6.1 2.3 4 0.8 5.7 1.9 316 17 310 165 -6.3 0.1 -5.9 -6.8 01/09/2007 16:10:00 4.6 0.6 6.1 3.4 4.5 0.6 6.1 3 3.9 0.5 5.3 2.6 306 8 298 165 -6.7 0.2 -6.1 -7 01/09/2007 16:20:00 4.2 0.8 5.7 2.3 4.1 0.8 5.7 2.3 3.8 0.6 5.3 2.3 314 9 300 165 -7 0 -6.8 -7.2 01/09/2007 16:30:00 1.5 1.1 3.8 0.4 1.5 1 3.4 0.4 1.3 1 3.4 0.4 296 19 310 165 -7.2 0.2 -6.8 -7.6 01/09/2007 16:40:00 0.8 0.3 1.5 0.4 0.9 0.3 1.9 0.4 1 0.3 1.5 0.4 124 35 109 165 -7.7 0 -7.4 -7.9 01/09/2007 16:50:00 0.4 0.2 1.1 0.4 0.5 0.2 1.1 0.4 0.5 0.2 1.1 0.4 144 22 108 165 -7.6 0 -7.4 -7.9 01/09/2007 17:00:00 1.2 1.3 5.3 0.4 1.3 1.3 5.3 0.4 1.3 1.3 5.3 0.4 208 58 286 165 -7.6 0 -7.4 -7.9 01/09/2007 17:10:00 6.2 0.7 7.6 4.2 6.2 0.7 7.6 4.2 5 0.8 7.2 3 298 6 289 165 -7.8 0.1 -7.4 -8.1 01/09/2007 17:20:00 5.8 0.6 7.2 4.6 5.7 0.6 7.6 4.6 5.5 0.4 6.5 3.8 315 9 304 165 -8 0.1 -7.6 -8.3 01/09/2007 17:30:00 4.9 0.4 6.5 3.8 4.7 0.7 6.5 1.9 5.1 0.4 6.5 4.2 342 9 348 165 -8.2 0 -8.1 -8.5 01/09/2007 17:40:00 4.7 0.7 6.1 2.6 4.3 1 6.1 1.5 5 0.8 6.1 2.3 343 10 337 165 -8 0 -7.6 -8.5 01/09/2007 17:50:00 3.2 0.7 4.6 1.1 2.8 0.7 4.6 0.7 3.2 0.7 4.6 1.5 333 29 350 165 -7.6 0.2 -7.2 -8.1 01/09/2007 18:00:00 3.8 0.5 4.9 2.3 3.8 0.5 4.9 2.3 3.3 0.6 4.6 1.9 305 9 304 165 -7.4 0.1 -7.2 -7.6 01/09/2007 18:10:00 3.4 0.6 4.6 1.5 3.4 0.5 4.9 1.9 3.1 0.6 4.6 1.9 309 13 325 165 -7.3 0.2 -6.8 -7.6 01/09/2007 18:20:00 4.4 1 6.1 1.5 4.5 1 6.1 1.9 3.9 1 5.7 1.5 290 7 293 165 -7.1 0 -6.8 -7.2 01/09/2007 18:30:00 2.6 1.3 5.3 0.4 2.8 1.3 5.3 0.4 2.6 1.3 5.7 0.4 256 51 290 165 -7.2 0.2 -6.8 -7.4 01/09/2007 18:40:00 1.5 0.6 3 0.4 1.5 0.6 3.4 0.4 1.6 0.6 2.6 0.4 171 16 211 165 -7.4 0.1 -7.2 -7.6 01/09/2007 18:50:00 2.4 1.3 4.2 0.4 2.6 1.2 4.2 0.4 2.4 1.3 4.6 0.4 254 29 270 165 -7.3 0.2 -6.8 -7.6 01/09/2007 19:00:00 2.9 0.4 3.8 1.5 3.2 0.4 3.8 1.9 3.1 0.5 4.2 1.5 277 13 307 165 -7.2 0 -6.8 -7.4 01/09/2007 19:10:00 2.9 0.4 3.8 1.9 3.1 0.4 3.8 2.3 2.4 0.6 3.8 0.7 288 11 288 165 -7.4 0.3 -6.8 -7.9 01/09/2007 19:20:00 2.5 0.6 3.4 1.1 2.6 0.6 3.4 0.7 2.2 0.3 3 1.5 305 18 294 165 -7.8 0 -7.6 -8.1 01/09/2007 19:30:00 1.2 0.5 2.3 0.4 1.1 0.5 2.3 0.4 1.8 0.5 2.6 0.4 348 13 347 165 -7.7 0 -7.4 -8.1 01/09/2007 19:40:00 0.9 0.5 2.3 0.4 1 0.6 2.3 0.4 1.2 0.6 2.3 0.4 151 72 128 165 -7.4 0 -7.2 -7.6 01/09/2007 19:50:00 0.7 0.6 2.6 0.4 0.7 0.7 2.6 0.4 0.6 0.6 2.3 0.4 153 72 286 165 -7.1 0.1 -6.8 -7.4 01/09/2007 20:00:00 1.2 0.8 3 0.4 1.4 0.9 3 0.4 1.5 0.8 3 0.4 359 82 102 165 -6.7 0.1 -6.6 -7 01/09/2007 20:10:00 0.6 0.5 2.3 0.4 0.7 0.6 2.6 0.4 0.9 0.7 2.6 0.4 91 33 103 165 -6.9 0 -6.6 -7 01/09/2007 20:20:00 0.9 0.5 1.9 0.4 1.1 0.6 2.3 0.4 1.2 0.6 1.9 0.4 135 30 136 165 -6.9 0.1 -6.6 -7.2 01/09/2007 20:30:00 0.5 0.2 1.1 0.4 0.7 0.4 1.5 0.4 0.9 0.5 1.9 0.4 240 49 260 165 -6.8 0.1 -6.6 -7.2 01/09/2007 20:40:00 0.4 0.1 1.1 0.4 0.5 0.3 1.5 0.4 0.8 0.4 2.3 0.4 215 47 268 165 -6.8 0 -6.6 -6.8 01/09/2007 20:50:00 0.7 0.4 1.5 0.4 0.9 0.5 1.9 0.4 1.2 0.5 2.3 0.4 190 56 269 165 -6.8 0.1 -6.6 -7 01/09/2007 21:00:00 1.3 0.6 2.3 0.4 1.5 0.5 2.6 0.4 1.5 0.5 2.6 0.4 288 11 284 165 -6.8 0.1 -6.6 -7.2 01/09/2007 21:10:00 2.1 0.6 3 0.4 2.1 0.7 3 0.4 2.3 0.4 3 1.1 326 20 316 165 -7.1 0 -6.8 -7.2 01/09/2007 21:20:00 1.9 0.8 3 0.4 2.1 0.7 3.4 0.4 1.7 0.5 2.6 0.7 296 5 297 165 -6.9 0 -6.8 -7.2 01/09/2007 21:30:00 0.5 0.2 1.1 0.4 0.6 0.4 1.5 0.4 0.6 0.3 1.5 0.4 275 26 298 165 -6.9 0 -6.8 -7 01/09/2007 21:40:00 1.1 0.4 1.9 0.4 1.3 0.4 1.9 0.4 1.4 0.4 2.3 0.4 213 16 228 165 -6.7 0 -6.6 -6.8 01/09/2007 21:50:00 1 0.6 2.3 0.4 1.2 0.5 2.3 0.4 1.2 0.5 2.3 0.4 191 7 187 165 -6.7 0 -6.6 -6.8 01/09/2007 22:00:00 1.2 0.5 1.9 0.4 1.4 0.3 1.9 0.7 1.5 0.3 1.9 0.7 172 5 166 165 -6.7 0 -6.6 -6.8 01/09/2007 22:10:00 0.8 0.4 1.9 0.4 1 0.4 1.9 0.4 1.3 0.3 1.9 0.7 177 5 172 165 -6.6 0 -6.6 -6.8 01/09/2007 22:20:00 0.8 0.5 1.9 0.4 1 0.5 1.9 0.4 1.1 0.4 2.3 0.4 171 10 165 165 -6.6 0 -6.4 -6.8 01/09/2007 22:30:00 0.8 0.4 1.9 0.4 0.9 0.4 1.9 0.4 1.1 0.3 1.9 0.4 174 6 172 165 -6.5 0 -6.4 -6.8 01/09/2007 22:40:00 1 0.6 2.3 0.4 1 0.7 2.3 0.4 1.2 0.6 2.6 0.4 162 8 146 165 -6.6 0 -6.6 -6.8 01/09/2007 22:50:00 1.8 0.5 2.6 0.4 1.8 0.4 2.6 0.7 1.8 0.4 2.6 0.7 149 7 154 165 -6.5 0 -6.4 -6.8 01/09/2007 23:00:00 2.3 0.3 3 1.5 2.3 0.3 2.6 1.5 2.1 0.3 2.6 1.5 138 4 136 165 -6.5 0 -6.4 -6.6 01/09/2007 23:10:00 2.6 0.4 3.4 1.5 2.5 0.3 3.4 1.5 2.4 0.3 3.4 1.5 136 6 143 165 -6.4 0 -6.1 -6.6 01/09/2007 23:20:00 2 0.4 3 1.1 2 0.4 3 1.1 1.9 0.3 2.6 1.1 128 9 150 165 -6.5 0 -6.4 -6.8 01/09/2007 23:30:00 2.3 0.4 3 1.5 2.3 0.3 3 1.1 2.2 0.3 3 1.1 130 9 136 165 -6.4 0.1 -6.1 -6.6 01/09/2007 23:40:00 2.5 0.5 3.4 1.5 2.4 0.5 3.4 1.1 2.5 0.4 3.4 1.1 141 14 145 165 -6.2 0 -6.1 -6.6 01/09/2007 23:50:00 2.6 0.6 4.2 1.1 2.5 0.6 3.8 1.1 2.7 0.5 4.2 1.5 142 11 147 165 -6.3 0 -6.1 -6.4 01/10/2007 00:00:00 3.2 0.7 4.9 1.5 3 0.7 4.6 1.5 3.1 0.6 4.6 1.5 150 6 148 165 -6.4 0 -6.1 -6.6 01/10/2007 00:10:00 3.5 0.6 4.9 1.9 3.3 0.6 4.6 1.9 3.6 0.5 4.9 2.3 152 10 151 165 -6.2 0 -5.9 -6.4 01/10/2007 00:20:00 3.5 0.4 4.2 2.6 3.3 0.4 4.2 2.3 3.3 0.4 4.2 2.3 154 11 124 165 -6.3 0 -6.1 -6.6 01/10/2007 00:30:00 4.3 0.4 4.9 3.4 4.1 0.4 4.6 3 4 0.5 4.9 2.6 153 12 156 165 -6.3 0 -6.1 -6.4 01/10/2007 00:40:00 4.3 0.6 6.1 2.6 4.1 0.6 5.7 2.3 4.1 0.5 5.7 2.6 150 13 155 165 -6.1 0 -5.9 -6.4 01/10/2007 00:50:00 4.6 0.6 6.1 3 4.4 0.6 5.7 3 4.5 0.6 6.1 3.4 153 21 160 165 -6 0 -5.7 -6.1 01/10/2007 01:00:00 3.8 0.9 4.9 1.9 3.5 0.8 4.6 1.9 3.8 0.9 5.7 2.3 155 19 166 165 -5.9 0 -5.7 -6.1 01/10/2007 01:10:00 4.3 0.6 5.7 3 4 0.5 5.3 2.6 4.3 0.5 5.7 3 160 15 167 165 -5.8 0 -5.5 -5.9 01/10/2007 01:20:00 4.5 0.4 5.7 3.4 4.2 0.4 5.3 3 4.5 0.5 5.7 3.4 152 17 173 165 -5.9 0 -5.7 -6.1 01/10/2007 01:30:00 3.7 0.4 4.6 2.6 3.4 0.4 4.2 2.6 3.6 0.4 4.6 2.6 154 15 157 165 -5.8 0 -5.5 -5.9 01/10/2007 01:40:00 3.7 0.3 4.2 2.6 3.5 0.3 4.2 2.6 3.7 0.4 4.6 2.6 155 15 174 165 -5.6 0 -5.5 -5.7 01/10/2007 01:50:00 3.5 0.3 4.2 2.6 3.3 0.3 4.2 2.6 3.4 0.3 4.2 2.6 162 11 162 165 -5.3 0.1 -5 -5.7 01/10/2007 02:00:00 3.9 0.4 4.6 2.6 3.8 0.4 4.6 2.6 3.7 0.4 4.6 2.6 187 8 188 165 -5.2 0 -4.8 -5.5 01/10/2007 02:10:00 3.3 0.4 4.2 2.3 3.2 0.4 4.2 2.3 3.2 0.4 4.2 2.3 184 6 187 165 -4.9 0 -4.6 -5.3 01/10/2007 02:20:00 3.2 0.6 4.9 2.3 3.1 0.6 4.6 2.3 3.1 0.5 4.2 2.3 169 12 188 165 -4.8 0 -4.6 -5 01/10/2007 02:30:00 3.2 0.3 4.6 2.3 3.1 0.3 4.6 2.6 3.1 0.3 4.2 2.3 155 10 162 165 -4.8 0 -4.6 -5 01/10/2007 02:40:00 3.3 0.3 3.8 2.6 3.2 0.3 4.2 2.6 3.3 0.2 3.8 2.6 150 8 145 165 -4.9 0 -4.6 -5 01/10/2007 02:50:00 3.4 0.6 4.9 1.9 3.4 0.6 4.9 1.9 3.4 0.5 4.9 2.6 152 14 146 165 -4.9 0 -4.6 -5.3 01/10/2007 03:00:00 3.3 0.8 4.9 1.5 3.2 0.8 4.9 1.5 3.3 0.7 4.9 1.9 166 19 148 165 -4.8 0 -4.6 -5 01/10/2007 03:10:00 3.4 0.6 4.2 1.5 3.2 0.6 4.2 1.5 3.3 0.7 4.2 1.1 168 15 172 165 -4.4 0.2 -3.9 -4.8 01/10/2007 03:20:00 3.7 0.5 5.3 3 3.6 0.4 5.3 2.6 3.8 0.3 4.9 3 158 11 178 165 -4 0 -3.9 -4.2 01/10/2007 03:30:00 4.7 0.6 6.1 3.4 4.6 0.6 5.7 3 4.8 0.7 6.5 3 150 13 157 165 -3.8 0.1 -3.5 -3.9 01/10/2007 03:40:00 5.1 0.6 6.8 3.8 5 0.6 6.1 3.8 5.2 0.5 6.5 4.2 151 15 167 165 -3.7 0 -3.5 -3.9 01/10/2007 03:50:00 4.3 0.5 5.7 2.6 4.1 0.5 5.3 2.6 4.4 0.5 5.7 3 158 14 168 165 -3.7 0 -3.5 -3.9 01/10/2007 04:00:00 4.7 0.5 6.1 3.8 4.5 0.4 5.7 3.4 4.8 0.5 6.1 3.8 152 19 187 165 -3.7 0 -3.5 -3.9 01/10/2007 04:10:00 5.1 0.7 6.8 3.4 4.8 0.7 6.5 3.4 4.9 0.7 6.5 3.8 165 22 188 165 -3.7 0 -3.3 -3.9 01/10/2007 04:20:00 4.7 0.7 6.5 3.4 4.4 0.7 6.1 3 4.7 0.7 6.5 3 169 16 169 165 -3.4 0 -3.3 -3.5 01/10/2007 04:30:00 5.8 0.6 7.2 4.6 5.5 0.6 6.8 4.2 5.5 0.6 6.8 4.2 150 23 142 165 -3.3 0.1 -3 -3.5 01/10/2007 04:40:00 5.8 1 7.2 3 5.4 0.9 6.8 2.6 5.6 0.9 7.2 3 151 19 165 165 -3.2 0 -2.8 -3.5 01/10/2007 04:50:00 4.6 0.7 6.1 3 4.3 0.6 5.7 2.6 4.6 0.7 6.1 3 156 19 159 165 -3.1 0.1 -2.8 -3.5 01/10/2007 05:00:00 4.8 0.5 6.5 3.4 4.5 0.5 5.7 3 4.8 0.4 6.1 3.8 159 15 175 165 -3.3 0 -3 -3.5 01/10/2007 05:10:00 4.2 0.4 5.3 3.4 3.9 0.4 4.9 3 4.1 0.4 4.9 3 161 14 162 165 -3.3 0 -3.3 -3.5 01/10/2007 05:20:00 4 0.5 5.7 3 3.6 0.4 5.3 3 3.7 0.3 4.6 3 162 15 166 165 -3.3 0 -3.3 -3.5 01/10/2007 05:30:00 4.4 0.5 6.1 3.4 4.1 0.5 5.3 3 4.1 0.4 5.3 3.4 163 17 154 165 -3.1 0 -2.8 -3.3 01/10/2007 05:40:00 4.4 0.4 5.7 3.4 4.1 0.4 5.3 3 4.2 0.4 5.3 3 155 17 90 165 -3 0 -2.8 -3.3 01/10/2007 05:50:00 5.1 0.6 6.8 3.8 4.8 0.6 6.1 3.4 4.8 0.6 6.5 3 156 22 159 165 -2.8 0 -2.6 -2.8 01/10/2007 06:00:00 6 1.1 8.8 3.4 5.6 1 8 3 5.7 1 7.6 3.4 168 18 181 165 -2.5 0.2 -1.9 -2.8 01/10/2007 06:10:00 6.4 0.6 8 4.6 6 0.6 7.6 4.6 5.9 0.6 7.2 4.2 155 26 165 165 -2.4 0.1 -1.9 -2.6 01/10/2007 06:20:00 5.9 1 8.4 3.8 5.5 1 8 3.8 5.6 0.9 7.6 4.2 160 22 158 165 -2.4 0.1 -2.1 -2.8 01/10/2007 06:30:00 6.7 1.2 9.1 4.6 6.3 1.1 8.8 4.2 6.3 1.2 9.5 4.6 169 19 183 165 -2.4 0.1 -2.1 -2.8 01/10/2007 06:40:00 6.1 0.8 8 3.8 5.7 0.8 7.6 3.8 5.6 0.8 7.6 4.2 162 22 167 165 -2.4 0 -2.1 -2.6 01/10/2007 06:50:00 5.1 0.8 8.4 3.4 4.9 0.8 8 3 5 0.6 7.6 3.8 155 17 175 165 -2.4 0 -2.1 -2.6 01/10/2007 07:00:00 5.7 0.5 7.2 4.6 5.5 0.5 6.8 4.6 5.7 0.5 7.2 4.2 154 17 151 165 -2.2 0 -1.9 -2.6 01/10/2007 07:10:00 6 0.6 7.6 4.6 5.7 0.5 7.2 4.2 5.7 0.5 6.8 4.6 162 22 178 165 -2 0 -1.9 -2.1 01/10/2007 07:20:00 3.8 0.8 7.2 1.9 3.7 0.8 6.8 1.9 3.9 0.6 6.5 2.6 164 15 182 165 -1.8 0 -1.4 -2.1 01/10/2007 07:30:00 2.2 0.9 4.6 0.4 2.2 0.9 4.6 0.4 2.4 0.9 4.2 0.4 170 15 166 165 -1.3 0 -1 -1.7 01/10/2007 07:40:00 2.8 0.7 4.6 0.7 2.6 0.7 4.6 0.7 3 0.6 4.9 1.5 165 16 161 165 -1.2 0 -1 -1.4 01/10/2007 07:50:00 2.3 1.1 4.6 0.4 2 1 4.6 0.4 2.5 0.9 4.6 0.4 155 16 152 165 -1 0 -0.8 -1.2 01/10/2007 08:00:00 4.1 0.9 5.7 1.9 3.8 0.9 5.7 1.9 4.2 1 6.1 2.3 154 10 158 165 -1 0 -0.8 -1.2 01/10/2007 08:10:00 6.8 0.8 8.8 4.6 6.5 0.8 8.4 4.6 6.8 0.8 9.1 4.9 160 17 180 165 -0.8 0.1 -0.5 -1 01/10/2007 08:20:00 7.6 0.8 9.5 5.7 7.2 0.7 9.1 5.3 7.5 0.8 9.5 5.7 159 21 158 165 -0.8 0 -0.5 -1 01/10/2007 08:30:00 9.1 0.9 10.7 7.2 8.6 0.8 9.9 6.5 9.1 0.9 10.7 6.8 161 16 170 165 -0.5 0 -0.3 -0.8 01/10/2007 08:40:00 8 0.7 11.1 6.1 7.6 0.7 10.7 5.7 7.9 0.6 9.9 6.1 153 26 147 165 -0.5 0 -0.3 -0.8 01/10/2007 08:50:00 8.6 0.8 10.7 5.7 8.3 0.8 10.3 5.3 8.8 0.8 10.7 6.1 159 22 167 165 -0.5 0 -0.3 -0.8 01/10/2007 09:00:00 8.5 0.8 10.7 6.8 8.2 0.8 9.9 6.5 8.6 0.7 10.3 6.8 155 23 156 165 -0.5 0.1 -0.1 -0.8 01/10/2007 09:10:00 8.7 0.7 11.1 6.5 8.4 0.7 10.7 6.5 8.8 0.7 10.7 6.5 154 23 166 165 -0.3 0 -0.1 -0.5 01/10/2007 09:20:00 8.7 0.8 10.7 6.8 8.4 0.7 10.3 6.5 8.7 0.7 10.7 6.8 157 23 173 165 -0.3 0 -0.1 -0.5 01/10/2007 09:30:00 10.3 0.8 12.2 8.4 9.9 0.7 11.8 8.4 10.5 0.8 12.6 8.8 160 28 167 165 -0.2 0 -0.1 -0.5 01/10/2007 09:40:00 10.7 0.6 12.2 9.1 10.4 0.6 11.8 8.8 11 0.6 12.2 9.5 145 30 106 165 0 0 0.2 -0.3 01/10/2007 09:50:00 10.5 0.8 13 8.4 10.2 0.7 12.6 8.4 10.7 0.7 12.6 8.8 145 30 169 165 0.2 0 0.4 -0.1 01/10/2007 10:00:00 10.2 0.8 11.8 7.6 9.9 0.8 11.8 7.6 10.5 0.8 12.6 8 148 22 152 165 0.3 0 0.7 0.2 01/10/2007 10:10:00 10 0.7 11.8 8.4 9.7 0.6 11.1 8 10.2 0.8 12.2 7.6 154 22 167 165 0.3 0 0.7 0.2 01/10/2007 10:20:00 10 0.8 11.8 8 9.9 0.9 12.2 8 10.1 0.8 12.2 8 154 24 166 165 0.3 0.1 0.7 0.2 01/10/2007 10:30:00 10.5 0.7 11.8 8.8 10.5 0.7 12.2 8.4 10.7 0.7 12.6 8.8 151 22 165 165 0.2 0 0.7 -0.1 01/10/2007 10:40:00 10.9 1.2 14.1 8.4 10.7 1.2 14.1 8 11 1.2 14.1 8 151 21 154 165 0.5 0 0.7 0.2 01/10/2007 10:50:00 11.4 0.9 13.7 9.1 11.2 0.9 13.3 9.1 11.4 1 14.1 9.1 151 22 162 165 0.5 0 0.7 0.4 01/10/2007 11:00:00 12.9 0.8 14.9 10.7 12.9 0.8 14.9 10.3 13.2 1 15.6 10.7 156 27 165 165 0.6 0 0.9 0.4 01/10/2007 11:10:00 13.4 0.9 16.1 11.1 13.4 0.9 16.1 10.7 13.7 1 16.4 11.1 158 26 172 165 0.7 0 0.9 0.7 01/10/2007 11:20:00 15.3 1.3 18.3 12.2 15.3 1.3 18.3 11.8 15.5 1.5 18.7 11.5 159 27 169 165 0.7 0 0.9 0.7 01/10/2007 11:30:00 16.3 1 18.7 12.6 16.2 0.9 18.3 12.6 16.6 0.9 19.1 13 159 27 165 165 0.7 0 0.9 0.7 01/10/2007 11:40:00 16.5 0.8 18.3 13.7 16.3 0.7 17.9 13.3 16.7 0.8 18.3 14.1 157 28 165 165 0.8 0 0.9 0.7 01/10/2007 11:50:00 15.6 0.8 17.9 13.7 15.4 0.8 17.6 13.7 15.9 0.8 18.3 13.3 147 29 158 165 0.8 0 0.9 0.7 01/10/2007 12:00:00 15.7 1.1 19.5 13 15.4 1.1 19.1 13 16 1.2 19.9 13.3 151 30 142 165 0.8 0 0.9 0.7 01/10/2007 12:10:00 17.2 0.6 18.7 15.6 16.8 0.6 18.3 15.3 17.6 0.8 19.5 15.3 141 33 166 165 0.8 0 1.1 0.9 01/10/2007 12:20:00 17.3 1.1 19.1 13.7 16.9 1.1 19.1 14.1 17.5 1.2 19.9 14.1 148 38 169 165 0.8 0 1.1 0.7 01/10/2007 12:30:00 18.3 1 20.6 15.3 17.8 1 20.2 14.5 18.4 1.1 20.6 15.3 140 43 148 165 0.8 0 1.1 0.7 01/10/2007 12:40:00 18.8 0.7 20.2 16.1 18.4 0.7 20.2 15.6 19.1 0.9 21.4 16.1 136 39 129 165 0.8 0 1.1 0.7 01/10/2007 12:50:00 17.3 1.2 19.9 13.3 16.9 1.2 19.5 12.6 17.4 1.3 20.2 13 131 38 161 165 0.8 0 0.9 0.7 01/10/2007 13:00:00 15.7 1.6 19.5 11.8 15.4 1.5 19.1 11.5 15.9 1.6 19.5 12.2 136 35 142 165 0.8 0 1.1 0.7 01/10/2007 13:10:00 13 1.1 15.3 9.1 12.7 1.1 14.9 9.1 13.3 1.1 15.3 10.3 137 30 56 165 0.8 0 0.9 0.7 01/10/2007 13:20:00 13.3 1.1 16.8 10.7 13 1 16.4 10.3 13.4 1 16.1 10.7 141 33 166 165 0.8 0 0.9 0.7 01/10/2007 13:30:00 13.9 1.2 16.4 11.1 13.6 1.1 16.1 11.1 14 1.3 17.2 11.5 141 38 90 165 0.9 0 1.1 0.7 01/10/2007 13:40:00 13.5 1 16.1 11.1 13.2 0.9 15.6 10.3 13.7 1 16.4 11.5 140 36 121 165 1 0 1.4 0.9 01/10/2007 13:50:00 14.1 1.3 17.2 10.7 13.9 1.3 17.2 10.7 14.2 1.3 17.6 11.1 147 38 135 165 1.1 0 1.4 0.9 01/10/2007 14:00:00 13.7 1.2 16.8 10.3 13.5 1.2 16.8 10.3 13.7 1.2 16.1 9.9 143 32 168 165 1.1 0 1.4 0.9 01/10/2007 14:10:00 12.9 1.4 18.7 9.5 12.6 1.4 18.3 9.5 13.1 1.2 18.3 10.7 145 28 166 165 0.9 0 1.4 0.9 01/10/2007 14:20:00 15.1 1.6 19.5 11.5 14.7 1.5 19.1 11.1 15.2 1.5 19.5 11.8 154 38 185 165 1.4 0.1 1.6 1.1 01/10/2007 14:30:00 14.8 1.3 18.7 9.9 14.4 1.3 18.3 9.9 15.1 1.3 17.9 10.3 158 27 172 165 1.4 0 1.6 1.1 01/10/2007 14:40:00 14.3 1.2 17.6 11.5 13.8 1.1 17.2 11.1 14.4 1.2 17.6 11.1 162 28 189 165 1.2 0 1.4 0.9 01/10/2007 14:50:00 15.1 1.1 18.3 12.2 14.6 1.1 17.6 11.8 15.5 1 18.7 12.6 166 22 176 165 1.3 0 1.6 1.1 01/10/2007 15:00:00 18.2 1.7 22.9 13.7 17.6 1.6 21.8 13.7 18.5 1.6 23.7 14.5 169 24 170 165 1.4 0 1.6 1.4 01/10/2007 15:10:00 16.8 2 21.8 12.2 16.4 1.9 21 12.2 17.1 1.8 21 13 173 15 166 165 1.5 0 1.6 1.4 01/10/2007 15:20:00 17.3 1.3 20.2 13.3 16.9 1.3 19.5 13.3 17.3 1.3 21 13.7 174 20 353 165 1.5 0.1 1.8 1.4 01/10/2007 15:30:00 16.5 1.2 19.9 12.2 16 1.2 19.5 12.6 16.7 1.3 20.2 12.2 176 16 166 165 1.4 0 1.6 1.4 01/10/2007 15:40:00 17.1 1.6 21.4 13 16.7 1.5 21 13 17.2 1.5 22.1 13.7 174 21 179 165 1.4 0 1.6 1.4 01/10/2007 15:50:00 13.8 1.8 19.1 10.3 13.5 1.7 18.3 9.9 13.8 1.8 19.1 9.9 179 12 181 165 1.3 0 1.4 1.1 01/10/2007 16:00:00 14 1.6 17.6 9.9 13.8 1.5 17.2 9.1 13.9 1.7 17.6 9.5 187 7 190 165 1.2 0 1.4 1.1 01/10/2007 16:10:00 15 1.2 18.7 11.8 14.9 1.2 18.3 11.8 15 1.2 18.3 11.8 189 5 194 165 1.4 0 1.6 1.1 01/10/2007 16:20:00 13.5 1.3 16.8 9.5 13.3 1.2 16.4 9.9 13.7 1.1 16.4 10.7 181 14 180 165 1.4 0 1.6 1.4 01/10/2007 16:30:00 13.8 1.4 17.6 10.3 13.4 1.3 17.2 9.9 14 1.3 17.6 10.3 171 17 179 165 1.2 0 1.4 0.9 01/10/2007 16:40:00 14.7 1.3 17.6 11.1 14.3 1.3 17.2 10.7 15.1 1.4 18.3 11.5 164 26 182 165 1.2 0 1.4 0.9 01/10/2007 16:50:00 17 1.3 19.9 12.6 16.8 1.2 19.1 12.6 17.3 1.3 20.2 13.3 170 26 171 165 1.3 0 1.4 1.1 01/10/2007 17:00:00 18.5 0.8 20.6 15.6 18.3 0.8 20.2 16.1 18.9 0.8 21.4 16.4 168 18 177 165 1.2 0 1.4 0.9 01/10/2007 17:10:00 18.5 0.9 21 15.3 18.4 0.8 20.2 15.6 18.9 0.9 21 15.6 170 16 170 165 1.2 0 1.4 0.9 01/10/2007 17:20:00 19.7 0.8 21.8 16.8 19.5 0.7 21.4 17.2 19.9 0.9 21.8 16.8 170 11 169 165 1.2 0 1.4 0.9 01/10/2007 17:30:00 20.7 0.8 23.3 17.2 20.4 0.7 22.6 17.2 20.9 0.8 22.6 18.3 169 17 179 165 1.2 0 1.4 0.9 01/10/2007 17:40:00 20.1 1 22.6 17.6 19.9 0.8 21.8 17.2 20.3 0.9 22.6 17.9 168 17 176 165 1.2 0 1.4 0.9 01/10/2007 17:50:00 21.5 1.1 23.7 18.3 21.1 1 23.3 18.3 21.4 1.1 24 18.3 168 17 168 165 1.2 0 1.4 0.9 01/10/2007 18:00:00 21.2 0.9 22.6 18.3 20.7 0.8 22.1 18.3 21.1 0.8 22.9 17.9 168 20 174 165 1.2 0 1.4 0.9 01/10/2007 18:10:00 21.4 1.1 23.3 16.8 20.8 1 22.9 16.8 21 1.1 23.3 16.4 165 24 175 165 1.2 0 1.4 0.9 01/10/2007 18:20:00 21.2 1.2 23.3 17.6 20.8 1.2 22.6 17.2 21 1.1 23.3 17.6 162 26 169 165 1.1 0 1.4 0.9 01/10/2007 18:30:00 20.7 0.9 22.6 17.9 20.1 0.9 21.8 17.2 20.4 1 22.6 17.6 161 27 166 165 1.1 0 1.4 0.9 01/10/2007 18:40:00 20.6 1 22.6 17.6 20 1 22.1 16.8 20.1 1.1 22.6 17.2 165 33 174 165 1.1 0 1.4 0.9 01/10/2007 18:50:00 19.3 1.2 22.1 16.4 18.8 1.1 21.4 16.1 18.9 1.2 21.8 15.6 163 29 166 165 1.1 0 1.4 0.9 01/10/2007 19:00:00 18.7 0.9 20.2 16.1 18.2 0.9 19.9 15.3 18.5 1 21 15.3 166 22 169 165 1.2 0 1.4 0.9 01/10/2007 19:10:00 18.8 1 21 16.1 18.3 1 20.6 15.3 18.5 1.1 21.4 15.3 166 23 171 165 1.3 0 1.4 1.1 01/10/2007 19:20:00 18.9 0.8 20.2 16.4 18.3 0.8 19.9 16.1 18.5 0.9 20.6 16.1 163 26 167 165 1.3 0 1.6 1.1 01/10/2007 19:30:00 18.2 1 19.9 15.3 17.6 0.9 19.5 14.9 17.6 1.1 19.9 14.5 161 32 170 165 1.4 0 1.6 1.4 01/10/2007 19:40:00 18.4 0.7 19.9 15.6 17.7 0.7 19.1 15.3 18 0.8 19.5 15.3 165 28 169 165 1.4 0 1.6 1.4 01/10/2007 19:50:00 18 0.8 19.5 14.5 17.5 0.7 19.1 14.1 17.6 1 19.1 13.7 159 33 167 165 1.5 0 1.6 1.4 01/10/2007 20:00:00 17.1 1.1 19.9 14.1 16.6 1 19.5 13.7 16.6 1.2 19.5 14.1 155 36 165 165 1.5 0 1.6 1.4 01/10/2007 20:10:00 17.3 0.8 19.1 14.5 16.6 0.8 18.3 14.1 16.9 0.9 18.7 14.1 164 27 168 165 1.5 0 1.6 1.4 01/10/2007 20:20:00 17.5 1 19.5 14.1 16.8 0.9 18.7 14.1 16.9 1 19.1 13.3 167 22 176 165 1.6 0 1.8 1.4 01/10/2007 20:30:00 17.7 0.8 19.5 15.3 17 0.7 18.3 14.5 17.3 0.9 19.5 14.9 162 29 177 165 1.7 0 1.8 1.6 01/10/2007 20:40:00 18.3 0.8 19.9 14.9 17.6 0.7 19.1 14.5 18 0.9 20.2 15.3 166 18 170 165 1.7 0 1.8 1.6 01/10/2007 20:50:00 17.3 0.9 19.1 14.9 16.8 0.8 18.3 14.5 17.1 0.9 19.1 14.5 156 32 165 165 1.7 0 1.8 1.6 01/10/2007 21:00:00 16.1 0.9 18.3 13.7 15.6 0.9 17.6 13.3 15.7 0.8 17.9 13.3 161 27 173 165 1.7 0 1.8 1.6 01/10/2007 21:10:00 16.5 1 19.1 13.7 16.2 1 18.3 13.3 16.4 1 18.3 13.7 154 41 167 165 1.8 0 1.8 1.6 01/10/2007 21:20:00 16 0.8 17.9 13.7 15.8 0.7 17.6 13.7 15.9 0.8 17.6 13.7 147 41 168 165 1.7 0 1.8 1.6 01/10/2007 21:30:00 15.7 0.6 17.2 13.3 15.5 0.6 17.2 13.3 15.8 0.7 17.9 13 138 49 136 165 1.7 0 1.8 1.6 01/10/2007 21:40:00 15.6 0.6 17.2 14.1 15.3 0.6 16.8 13.7 15.6 0.8 17.6 13 140 41 166 165 1.7 0 1.8 1.6 01/10/2007 21:50:00 15.6 0.7 17.2 13 15.3 0.7 16.8 12.6 15.8 0.7 17.6 12.6 132 47 168 165 1.8 0 1.8 1.6 01/10/2007 22:00:00 17.1 1 19.5 14.1 16.7 0.9 19.1 13.7 17.3 1 19.9 14.1 146 47 172 165 1.8 0 1.8 1.6 01/10/2007 22:10:00 16.8 0.8 19.5 14.1 16.6 0.8 19.1 14.1 17.4 0.8 19.5 14.1 152 43 323 165 1.8 0 1.8 1.6 01/10/2007 22:20:00 16.1 1 18.7 13 16.1 1 18.3 13.3 17.3 1 19.5 14.1 155 38 177 165 1.8 0 1.8 1.6 01/10/2007 22:30:00 17.2 1 19.5 14.5 16.6 0.9 18.3 14.1 17.8 1 20.2 14.9 150 39 171 165 1.9 0 2.1 1.8 01/10/2007 22:40:00 17.8 1.2 20.6 14.9 17.3 1.2 20.2 14.5 18.1 1.2 21 15.3 145 45 166 165 2 0 2.3 1.8 01/10/2007 22:50:00 18.1 0.9 20.6 16.1 17.7 0.8 20.2 15.3 18.4 0.9 20.2 15.6 145 39 165 165 2 0 2.3 1.8 01/10/2007 23:00:00 19 1 21.4 15.6 18.7 1 20.6 15.3 19.3 1 21.4 16.1 147 45 111 165 2 0 2.3 1.8 01/10/2007 23:10:00 18.8 1.2 22.1 16.4 18.5 1.2 21.8 16.1 18.9 1.2 22.1 16.1 154 41 173 165 2 0 2.3 1.8 01/10/2007 23:20:00 18.6 0.8 20.2 16.1 18.3 0.8 19.9 16.1 18.7 0.8 20.6 16.1 154 39 166 165 2 0 2.3 1.8 01/10/2007 23:30:00 18.4 1.1 21.8 14.9 18 1.1 21 14.5 18.5 1.1 21.8 14.9 154 43 165 165 2 0 2.3 1.8 01/10/2007 23:40:00 18.3 1 20.6 14.9 17.7 1 19.9 14.5 18.4 1 21.8 15.6 157 41 139 165 2 0 2.3 1.8 01/10/2007 23:50:00 18.1 0.9 19.9 15.3 17.5 0.8 19.1 14.9 18.1 1 20.2 15.6 161 28 169 165 1.9 0 2.1 1.8 01/11/2007 00:00:00 18.3 1 20.6 15.3 17.9 1 20.2 14.9 18.5 1.1 21 15.6 160 32 168 165 1.9 0 2.3 1.8 01/11/2007 00:10:00 19.3 0.7 21 16.8 18.8 0.7 21 16.4 19.3 0.9 21.4 16.4 162 22 169 165 1.9 0 2.1 1.8 01/11/2007 00:20:00 18.7 0.9 21 16.1 18.2 0.8 20.6 16.1 18.8 1 21.8 15.6 158 33 166 165 1.9 0 2.1 1.8 01/11/2007 00:30:00 17 1 19.9 14.1 16.6 1 19.5 14.1 17.3 1 20.2 14.5 154 36 82 165 1.9 0 2.1 1.8 01/11/2007 00:40:00 15.4 1.1 18.7 12.6 15 1.1 18.7 12.2 15.4 1.1 18.7 12.6 154 35 171 165 2 0 2.3 1.8 01/11/2007 00:50:00 15.6 0.9 17.6 13 15.1 0.9 17.2 12.6 15.6 1 17.6 12.6 161 28 183 165 2 0 2.3 1.8 01/11/2007 01:00:00 15.1 1 17.6 11.8 14.6 0.9 16.8 11.8 15.1 1.1 17.2 11.8 164 30 165 165 2.1 0 2.3 1.8 01/11/2007 01:10:00 15 0.9 17.6 12.6 14.6 0.8 16.8 12.6 14.9 0.9 17.2 12.6 163 24 171 165 2.1 0 2.3 2.1 01/11/2007 01:20:00 15.9 1.2 18.3 13 15.4 1.2 17.9 12.2 15.9 1.3 18.7 12.2 162 30 169 165 2.1 0 2.3 1.8 01/11/2007 01:30:00 16.4 1.3 19.1 13.3 16 1.2 18.7 13 16.3 1.2 19.1 13.7 162 30 168 165 2.1 0 2.3 1.8 01/11/2007 01:40:00 16.2 1.1 19.1 12.2 15.7 1 18.3 11.8 16.1 1.1 19.1 12.2 162 27 41 165 2.2 0 2.3 2.1 01/11/2007 01:50:00 14.9 1.2 17.2 11.5 14.5 1.2 16.8 11.5 14.7 1.2 17.9 11.8 160 35 172 165 2.2 0 2.3 2.1 01/11/2007 02:00:00 12.8 1.3 15.3 9.9 12.4 1.2 14.9 9.1 12.9 1.2 14.9 9.9 161 27 169 165 2.1 0 2.3 2.1 01/11/2007 02:10:00 10.7 1.1 13.3 8 10.3 1.1 13 8 10.8 1 13 8.4 168 20 175 165 2.2 0 2.6 2.1 01/11/2007 02:20:00 9.3 1.2 12.6 6.8 9 1.2 12.2 6.1 9.4 1.2 12.6 6.5 165 23 179 165 2.2 0 2.6 1.8 01/11/2007 02:30:00 7.7 1 10.7 5.3 7.5 1 10.3 5.3 7.8 0.8 10.3 5.7 169 17 188 165 2.2 0 2.3 1.8 01/11/2007 02:40:00 7.7 1.2 11.5 5.7 7.4 1.1 11.1 5.7 7.6 1 11.5 5.7 169 18 186 165 2.1 0 2.3 1.8 01/11/2007 02:50:00 9.4 1.7 13.7 6.5 9.2 1.7 13.3 5.7 9.5 1.7 14.1 6.5 163 26 173 165 2.1 0 2.3 1.8 01/11/2007 03:00:00 12.6 1.5 17.6 9.5 12.2 1.5 16.8 9.1 12.6 1.4 16.8 9.9 168 23 174 165 2.2 0 2.3 1.8 01/11/2007 03:10:00 12.7 1.3 16.4 9.9 12.3 1.2 16.1 9.5 12.8 1.3 16.8 10.3 173 22 177 165 2.3 0 2.6 2.1 01/11/2007 03:20:00 11.2 1.3 14.5 8.4 10.8 1.2 14.1 8 11.3 1.3 14.5 8.8 177 15 175 165 2.2 0 2.6 2.1 01/11/2007 03:30:00 12.9 1.7 17.2 9.1 12.4 1.7 16.4 9.1 12.8 1.5 17.2 9.1 170 23 184 165 2.1 0 2.3 1.8 01/11/2007 03:40:00 15.1 1.5 18.3 11.5 14.7 1.4 17.9 11.5 15.1 1.4 18.3 11.5 168 22 173 165 2.2 0 2.6 2.1 01/11/2007 03:50:00 16.3 1.2 19.1 13.3 15.9 1.1 18.7 13 16.1 1.3 19.1 12.6 159 32 174 165 2.3 0 2.6 2.1 01/11/2007 04:00:00 18.5 1.3 21.4 14.5 18.1 1.2 21 14.1 18.4 1.3 21.8 14.5 158 32 157 165 2.4 0 2.6 2.3 01/11/2007 04:10:00 19.3 0.8 21 16.4 19 0.8 20.6 16.1 19.2 1 21 16.4 152 35 168 165 2.4 0 2.8 2.3 01/11/2007 04:20:00 17.7 0.9 19.5 15.3 17.3 0.9 19.1 14.5 17.6 1.1 20.2 13.7 154 35 165 165 2.4 0 2.6 2.3 01/11/2007 04:30:00 17.3 1 19.5 14.5 17 1 19.1 14.1 17.3 1.1 19.9 14.1 160 29 174 165 2.4 0 2.6 2.3 01/11/2007 04:40:00 16.2 1 18.7 13.7 15.8 1 18.3 13.7 16.3 1 18.7 14.1 155 35 73 165 2.4 0 2.6 2.3 01/11/2007 04:50:00 14.8 1 16.8 11.5 14.5 1 16.4 11.8 14.7 1.1 16.8 11.5 156 28 167 165 2.4 0 2.6 2.1 01/11/2007 05:00:00 14.8 1.2 17.9 11.8 14.5 1.2 17.6 11.8 14.8 1.3 18.3 11.8 157 35 169 165 2.3 0 2.6 2.1 01/11/2007 05:10:00 14.5 1 17.2 11.5 14.2 1 16.8 11.5 14.6 1 18.3 11.8 156 32 172 165 2.4 0 2.6 2.3 01/11/2007 05:20:00 14.2 1 16.1 11.1 13.8 0.9 15.6 10.7 14.2 1 16.4 10.7 151 38 130 165 2.4 0 2.6 2.3 01/11/2007 05:30:00 14.2 1 17.6 11.8 14 1 16.8 11.5 14 1 16.8 11.5 151 35 148 165 2.4 0 2.6 2.3 01/11/2007 05:40:00 15.1 1.3 18.7 12.2 14.8 1.2 17.9 11.8 15 1.3 18.7 11.5 144 43 145 165 2.4 0 2.6 2.3 01/11/2007 05:50:00 15.9 1.2 18.7 11.8 15.6 1.2 18.3 11.8 15.7 1.4 18.7 11.8 148 41 172 165 2.4 0 2.8 2.3 01/11/2007 06:00:00 14.8 1.1 17.2 11.8 14.5 1 16.8 11.8 14.6 1.1 17.2 11.8 148 38 171 165 2.4 0 2.6 2.3 01/11/2007 06:10:00 15.4 1 18.7 12.6 15.2 1 18.3 12.2 15.3 1.1 18.3 11.5 149 38 173 165 2.4 0 2.6 2.3 01/11/2007 06:20:00 16.8 1.2 20.2 13 16.6 1.2 19.9 13.3 16.8 1.2 20.2 13.3 158 39 166 165 2.4 0 2.6 2.3 01/11/2007 06:30:00 16.9 1.1 19.1 13 16.6 1.1 18.7 12.6 16.7 1.1 19.5 13.3 149 43 168 165 2.4 0 2.6 2.3 01/11/2007 06:40:00 16.5 1.1 19.1 13 16.2 1.1 18.7 13.3 16.3 1.3 19.5 12.6 147 41 165 165 2.3 0 2.6 2.1 01/11/2007 06:50:00 17.4 1 19.1 14.1 17.1 1 19.1 13.7 17.4 1.1 19.9 14.1 153 39 129 165 2.3 0 2.6 2.1 01/11/2007 07:00:00 17 1 19.9 14.5 16.7 1.1 19.5 14.1 17.1 1.2 19.9 14.1 159 35 165 165 2.3 0 2.6 2.1 01/11/2007 07:10:00 17.3 1 19.9 14.9 16.9 0.9 19.5 14.5 17.4 1 19.9 14.5 155 38 174 165 2.4 0 2.6 2.1 01/11/2007 07:20:00 19.4 1.2 22.9 16.4 19 1.2 22.6 16.1 19.4 1.2 22.9 15.6 165 20 153 165 2.4 0 2.6 2.3 01/11/2007 07:30:00 20.5 1.1 23.3 17.2 20 1.1 22.9 16.4 20.5 1.3 23.3 16.4 167 11 166 165 2.4 0 2.6 2.3 01/11/2007 07:40:00 19.9 1.1 22.9 16.4 19.5 1 22.6 16.4 19.9 1.1 23.3 16.4 167 18 169 165 2.4 0 2.6 2.3 01/11/2007 07:50:00 20.1 1.4 24.4 17.2 19.6 1.4 23.7 16.8 20.2 1.5 24 16.4 163 22 171 165 2.3 0 2.6 2.3 01/11/2007 08:00:00 21.5 1.1 24.4 18.3 21.1 1.1 24 17.9 21.7 1.3 24.8 17.9 156 29 129 165 2.3 0 2.6 2.1 01/11/2007 08:10:00 21.2 1.5 25.2 17.6 20.9 1.4 24.4 17.6 21.3 1.5 24.8 17.9 158 27 167 165 2.2 0 2.6 2.1 01/11/2007 08:20:00 21.3 1.3 25.2 17.2 20.9 1.3 25.2 16.8 21.4 1.5 26 16.4 160 29 166 165 2.1 0 2.3 2.1 01/11/2007 08:30:00 20.4 1.3 22.9 17.2 19.9 1.2 22.6 16.8 20.5 1.5 23.3 16.8 164 22 169 165 2.1 0 2.3 1.8 01/11/2007 08:40:00 18.7 1.2 21.8 15.6 18.3 1.1 21.4 15.3 19.1 1.2 22.1 15.6 164 21 170 165 2 0 2.3 1.8 01/11/2007 08:50:00 19.1 0.8 21 16.1 18.7 0.9 20.2 15.6 19.2 1 21.8 15.6 167 18 173 165 2 0 2.3 1.8 01/11/2007 09:00:00 19.9 1.1 22.1 16.8 19.4 1.1 21.8 16.4 20 1.3 22.9 17.2 164 28 170 165 2 0 2.3 1.8 01/11/2007 09:10:00 20.5 1 22.6 17.9 20.1 1 22.6 17.2 20.8 1 24 17.9 157 30 167 165 2 0 2.3 1.8 01/11/2007 09:20:00 20.9 1 23.3 17.9 20.5 0.9 22.9 17.6 21.1 1 23.3 18.3 152 41 172 165 2 0 2.3 1.8 01/11/2007 09:30:00 21.2 1.1 23.3 17.9 20.8 1.1 23.3 17.2 21.3 1.2 24 17.2 155 39 166 165 2 0 2.3 1.8 01/11/2007 09:40:00 20 1.1 22.6 15.3 19.7 1.1 22.1 15.3 20 1.3 22.1 15.3 148 41 167 165 2 0 2.3 1.8 01/11/2007 09:50:00 19.7 1.2 22.6 15.6 19.4 1.2 22.1 15.3 19.9 1.2 22.6 16.4 152 41 142 165 2 0 2.3 1.8 01/11/2007 10:00:00 19.8 0.9 22.9 17.2 19.4 0.9 22.1 16.8 20 1 22.9 16.8 156 36 173 165 2 0 2.3 1.8 01/11/2007 10:10:00 18.7 1 21 15.6 18.4 1 21 15.6 18.7 1.1 21.4 15.6 155 38 172 165 2 0 2.3 1.8 01/11/2007 10:20:00 19.2 1.2 22.9 15.6 18.8 1.2 23.3 15.6 19.3 1.3 24.4 15.3 149 47 166 165 2 0 2.3 1.8 01/11/2007 10:30:00 20.8 1.3 24 16.8 20.4 1.3 23.3 16.8 21 1.3 24 17.6 156 39 174 165 2 0 2.3 1.8 01/11/2007 10:40:00 19.4 1.6 24.4 16.4 19 1.5 23.7 15.6 19.4 1.7 24.8 14.9 157 33 171 165 2 0 2.3 1.8 01/11/2007 10:50:00 19.5 1.2 22.1 16.4 19.1 1.2 21.8 16.4 19.8 1.2 22.6 17.2 161 32 165 165 1.9 0 2.1 1.8 01/11/2007 11:00:00 19.8 1.2 22.9 16.4 19.4 1.2 21.8 16.1 20 1.1 22.6 16.8 164 27 121 165 1.9 0 2.1 1.6 01/11/2007 11:10:00 18 1.3 21 14.5 17.5 1.3 20.2 14.1 18.1 1.3 21.4 14.5 150 43 120 165 1.8 0 2.1 1.6 01/11/2007 11:20:00 17.7 1.7 21 13.3 17.3 1.7 20.6 13 17.6 1.7 21 12.6 162 38 176 165 1.9 0 2.3 1.8 01/11/2007 11:30:00 20 1.8 24 16.1 19.5 1.7 23.3 16.1 20.1 1.8 24.4 16.1 163 33 168 165 2 0 2.3 1.8 01/11/2007 11:40:00 19.8 1.5 23.7 15.3 19.4 1.5 23.3 15.3 20 1.3 24 16.1 167 24 173 165 2.1 0 2.3 1.8 01/11/2007 11:50:00 19.1 1.1 21.4 16.4 18.6 1 21 15.6 19.1 1.1 21.8 16.4 167 22 169 165 2 0 2.3 1.8 01/11/2007 12:00:00 18.1 1 20.6 15.6 17.6 0.9 20.2 15.3 18.1 1.1 20.6 14.5 162 30 172 165 2 0 2.3 1.8 01/11/2007 12:10:00 17.7 1 20.6 15.3 17.3 1 20.2 14.9 17.8 1.1 20.6 15.3 160 29 172 165 2 0 2.3 1.8 01/11/2007 12:20:00 17.8 1.1 21 14.9 17.5 1.1 20.6 14.5 17.9 1.2 21.8 15.3 159 28 166 165 2.1 0 2.3 1.8 01/11/2007 12:30:00 19.3 0.8 21.4 17.2 18.9 0.8 20.6 16.4 19.4 1 21.4 16.4 163 24 176 165 2.1 0 2.3 1.8 01/11/2007 12:40:00 18 1.3 21.4 14.5 17.6 1.2 21 13.7 18 1.2 21.4 14.9 161 33 173 165 2.2 0 2.3 1.8 01/11/2007 12:50:00 18.6 1.5 22.9 14.5 18.2 1.4 22.6 13.7 18.7 1.5 22.6 14.9 156 36 172 165 2.1 0 2.3 1.8 01/11/2007 13:00:00 18.2 1.1 21.4 15.6 17.9 1 21 15.3 18.3 1.1 21 15.6 159 36 170 165 2.2 0 2.6 1.8 01/11/2007 13:10:00 16.8 1.1 19.5 13.7 16.5 1.1 19.1 13.3 16.8 1.2 19.9 13.7 156 38 171 165 2.1 0 2.3 1.8 01/11/2007 13:20:00 16 1.2 19.1 13 15.7 1.2 18.7 13 16 1.2 19.1 13.7 153 33 175 165 2.1 0 2.3 1.8 01/11/2007 13:30:00 16.9 1.3 19.5 14.1 16.6 1.3 19.5 13.7 16.9 1.5 19.9 13.3 153 41 174 165 2.1 0 2.3 1.8 01/11/2007 13:40:00 14.8 1 17.2 12.2 14.6 0.9 16.8 11.8 14.8 1 16.8 12.2 143 39 166 165 2.1 0 2.3 1.8 01/11/2007 13:50:00 16.4 1 18.7 13.7 16 1 17.9 13.3 16.5 1.1 19.1 13 165 24 174 165 2.3 0 2.6 2.1 01/11/2007 14:00:00 12.3 1 15.3 9.9 12 1 15.3 9.5 12.4 1 14.9 10.3 145 28 173 165 2 0.1 2.3 1.8 01/11/2007 14:10:00 11.8 0.9 14.1 9.5 11.6 0.8 14.1 9.5 11.8 0.9 14.1 9.5 140 32 160 165 1.9 0 2.3 1.8 01/11/2007 14:20:00 11.7 0.9 13.7 9.1 11.5 0.9 13.7 9.1 11.6 0.9 13.7 9.1 133 39 63 165 1.9 0 2.3 1.8 01/11/2007 14:30:00 11.5 0.7 13 8.8 11.3 0.7 13 9.1 11.5 0.7 13 9.5 137 35 165 165 2 0 2.3 1.8 01/11/2007 14:40:00 11.5 0.6 13 9.9 11.2 0.6 12.6 9.5 11.6 0.6 13.3 9.5 142 22 147 165 2 0 2.3 1.8 01/11/2007 14:50:00 11 0.7 12.6 9.1 10.7 0.7 12.6 9.1 11.1 0.7 13 8.8 143 22 133 165 1.9 0 2.3 1.8 01/11/2007 15:00:00 11.2 1 13.7 8.4 11.1 0.9 13.7 8.8 11.2 1 13.3 8.8 136 36 35 165 1.9 0 2.1 1.8 01/11/2007 15:10:00 11.6 1 13.7 8.8 11.4 1 13.3 9.1 11.6 1.1 14.9 8 135 41 124 165 1.8 0 1.8 1.6 01/11/2007 15:20:00 11.6 0.5 12.6 9.5 11.2 0.5 12.2 9.1 11.5 0.6 12.6 9.9 135 47 48 165 1.7 0 1.8 1.6 01/11/2007 15:30:00 11.6 0.6 13.3 9.5 11.3 0.5 13 9.5 11.7 0.6 13.3 9.9 131 43 173 165 1.5 0 1.8 1.4 01/11/2007 15:40:00 11.4 0.4 12.2 10.3 10.9 0.4 11.8 9.9 11.2 0.5 12.6 9.1 133 41 65 165 1.5 0 1.6 1.4 01/11/2007 15:50:00 11.7 0.5 13 10.3 11.2 0.5 12.6 9.9 11.4 0.6 13 9.5 134 41 166 165 1.5 0 1.6 1.4 01/11/2007 16:00:00 10.6 0.5 12.6 9.5 10.1 0.5 11.8 9.1 10.5 0.5 12.2 8.8 145 39 97 165 1.5 0 1.6 1.4 01/11/2007 16:10:00 10 0.8 11.8 8.4 9.6 0.8 11.5 8 9.8 0.8 11.8 6.8 151 17 154 165 1.5 0 1.6 1.4 01/11/2007 16:20:00 12.4 1.1 14.1 9.9 12.1 1.1 13.7 9.5 12.4 1.1 14.5 9.9 154 0 154 165 1.5 0 1.6 1.4 01/11/2007 16:30:00 12.2 1.2 14.1 9.1 11.8 1.2 13.7 9.1 12.2 1.3 14.5 8.8 154 0 154 165 1.5 0 1.6 1.4 01/11/2007 16:40:00 12 0.6 13.7 9.9 11.6 0.6 13.3 9.5 12.2 0.7 13.7 9.9 154 0 154 165 1.5 0 1.6 1.4 01/11/2007 16:50:00 14.1 0.9 16.1 11.5 13.7 0.8 15.6 11.1 14.5 1 16.4 12.2 154 0 154 165 1.6 0 1.8 1.4 01/11/2007 17:00:00 14.4 0.7 16.1 11.8 13.9 0.7 15.6 11.5 15 0.7 16.4 13 154 0 154 165 1.5 0 1.6 1.4 01/11/2007 17:10:00 13.4 0.9 15.6 11.1 12.8 0.8 14.9 10.7 14 1 16.4 11.1 154 0 154 165 1.5 0 1.6 1.4 01/11/2007 17:20:00 12.6 0.6 14.1 10.3 11.9 0.6 13.7 9.9 13 0.7 14.9 10.3 154 0 154 165 1.5 0 1.6 1.4 01/11/2007 17:30:00 12.3 0.5 13.7 10.7 11.8 0.5 13 10.3 12.6 0.6 13.7 11.1 154 0 154 165 1.4 0 1.8 1.4 01/11/2007 17:40:00 12.7 0.5 13.7 11.1 12.2 0.5 13.3 10.7 13.1 0.6 14.5 11.5 154 0 155 165 1.4 0 1.6 1.4 01/11/2007 17:50:00 11.8 1 14.1 9.5 11.5 0.8 13.7 9.5 12.1 1 14.5 9.5 154 0 155 165 1.4 0 1.6 1.4 01/11/2007 18:00:00 12.2 0.5 13.3 11.1 11.6 0.5 12.6 10.3 12.3 0.5 13.7 10.7 154 0 154 165 1.5 0 1.8 1.4 01/11/2007 18:10:00 12.5 0.6 14.1 10.7 11.9 0.6 13.3 9.9 12.7 0.6 14.1 10.3 154 0 155 165 1.5 0 1.6 1.4 01/11/2007 18:20:00 13.6 0.6 14.9 11.5 12.7 0.5 14.1 10.7 13.6 0.7 15.3 11.5 154 0 155 165 1.5 0 1.8 1.4 01/11/2007 18:30:00 13.5 0.6 14.9 11.8 12.5 0.6 13.7 10.7 13.3 0.7 14.9 11.8 154 0 154 165 1.5 0 1.6 1.4 01/11/2007 18:40:00 13.5 0.8 15.3 11.1 12.2 0.6 13.7 10.3 12.8 0.7 14.5 10.7 154 0 155 165 1.4 0 1.6 1.4 01/11/2007 18:50:00 12.6 0.9 14.5 9.9 11.3 0.7 13 9.1 11.8 0.8 13.3 9.5 154 0 155 165 1.4 0 1.8 1.4 01/11/2007 19:00:00 10.8 0.8 12.6 8.4 9.7 0.6 11.5 8.4 10.1 0.7 11.5 8 154 0 155 165 1.5 0 1.6 1.4 01/11/2007 19:10:00 10.5 0.8 12.2 8 9.3 0.6 10.7 7.6 9.8 0.6 11.1 7.6 154 0 154 165 1.5 0 1.8 1.4 01/11/2007 19:20:00 10.5 0.8 11.8 8 9.2 0.6 10.3 7.6 9.7 0.6 11.1 7.6 154 0 155 165 1.5 0 1.8 1.4 01/11/2007 19:30:00 10.3 0.7 11.8 8 9.1 0.6 10.3 6.8 9.7 0.6 10.7 7.6 154 0 155 165 1.5 0 1.8 1.4 01/11/2007 19:40:00 10.1 1 12.2 8 9 0.7 10.7 7.2 9.5 0.6 11.1 8 154 0 155 165 1.5 0 1.6 1.4 01/11/2007 19:50:00 9.8 0.8 12.2 7.2 8.7 0.6 10.3 6.8 9.1 0.6 10.7 7.2 154 0 155 165 1.5 0 1.8 1.4 01/11/2007 20:00:00 9.8 0.9 11.5 7.2 8.7 0.7 9.9 6.8 8.9 0.6 10.3 6.8 154 0 154 165 1.5 0 1.8 1.4 01/11/2007 20:10:00 9.7 1 11.8 7.2 8.6 0.7 10.3 6.8 9 0.6 10.7 7.2 154 0 154 165 1.5 0 1.8 1.4 01/11/2007 20:20:00 9.8 1 12.2 7.2 8.7 0.8 10.7 6.8 8.9 0.8 11.1 7.2 154 0 155 165 1.5 0 1.8 1.4 01/11/2007 20:30:00 9.7 0.8 11.1 7.6 8.8 0.6 10.3 7.2 9 0.6 10.7 7.6 154 0 154 165 1.5 0 1.8 1.4 01/11/2007 20:40:00 10 1 12.2 7.2 9.3 0.7 10.7 7.2 9.6 0.7 11.1 7.2 154 0 154 165 1.5 0 1.6 1.4 01/11/2007 20:50:00 9.1 0.8 11.1 7.2 8.8 0.6 10.3 7.2 9.2 0.7 10.7 6.8 154 0 154 165 1.5 0 1.8 1.4 01/11/2007 21:00:00 9 0.5 10.3 7.6 8.8 0.4 9.9 7.6 9 0.4 9.9 7.6 154 0 155 165 1.4 0 1.8 1.4 01/11/2007 21:10:00 9.2 0.7 10.7 7.2 9.1 0.5 9.9 7.2 9.3 0.6 10.7 7.6 154 0 155 165 1.4 0 1.6 1.4 01/11/2007 21:20:00 10.2 0.8 12.2 8 10 0.6 11.8 8 10.2 0.6 11.8 8 154 0 154 165 1.4 0 1.6 1.4 01/11/2007 21:30:00 9.6 0.8 11.5 7.6 9.8 0.7 11.1 8 9.8 0.7 11.5 8 154 0 154 165 1.4 0 1.6 1.4 01/11/2007 21:40:00 9.6 0.8 11.5 7.2 9.9 0.8 11.5 7.6 9.9 0.8 11.8 7.2 154 0 154 165 1.4 0 1.6 1.4 01/11/2007 21:50:00 10.2 0.9 12.2 8.4 10.5 0.9 12.2 8.4 10.7 0.9 12.6 8.8 154 0 154 165 1.4 0 1.6 1.4 01/11/2007 22:00:00 10 0.5 11.5 8.8 9.8 0.5 11.1 8.4 10.9 0.6 12.2 9.1 154 0 155 165 1.3 0 1.6 1.1 01/11/2007 22:10:00 9 0.5 10.7 7.6 8.8 0.5 10.3 7.2 10.3 0.6 11.8 8.4 154 0 154 165 1.2 0 1.6 1.1 01/11/2007 22:20:00 9 0.6 10.7 7.2 8.8 0.6 10.7 7.2 10.4 0.8 12.2 8 154 0 155 165 1.3 0 1.6 1.4 01/11/2007 22:30:00 9.1 0.5 11.1 7.2 8.9 0.6 11.1 6.8 10.7 0.9 13 8.4 154 0 154 165 1.3 0 1.6 1.1 01/11/2007 22:40:00 8.2 0.7 9.9 6.5 7.9 0.7 9.5 6.1 9.6 0.9 11.8 6.5 154 0 155 165 1.2 0 1.4 0.9 01/11/2007 22:50:00 7.7 0.8 9.1 5.7 7.4 0.7 9.1 5.3 9.2 1.1 11.5 6.5 154 0 154 165 1.1 0 1.4 0.9 01/11/2007 23:00:00 7.7 0.5 8.8 6.5 7.4 0.5 8.8 6.5 9.4 0.8 11.5 7.6 154 0 154 165 1.1 0 1.4 0.9 01/11/2007 23:10:00 8.2 0.5 9.5 6.8 7.7 0.5 8.8 6.5 9.5 0.7 11.1 8 154 0 154 165 1.2 0 1.6 0.9 01/11/2007 23:20:00 8 0.6 9.1 6.1 7.6 0.5 8.8 5.3 9.4 0.7 11.1 7.6 154 0 154 165 1.1 0 1.4 0.9 01/11/2007 23:30:00 8.3 0.8 9.9 5.7 8 0.6 9.1 5.3 9.8 1 11.5 6.5 154 0 154 165 1.1 0 1.4 0.9 01/11/2007 23:40:00 7.9 0.8 9.5 4.9 7.4 0.8 9.1 4.6 9 1 11.1 6.1 154 0 154 165 1.1 0 1.4 0.9 01/11/2007 23:50:00 7.6 0.6 9.1 6.1 7 0.6 8.4 5.7 8.7 0.9 10.7 6.5 154 0 155 165 1 0 1.4 0.9 01/12/2007 00:00:00 6.3 0.8 8 4.6 5.4 0.8 6.8 3.8 7.6 1 9.9 5.3 154 0 154 165 0.8 0.1 1.4 0.9 01/12/2007 00:10:00 5.5 0.7 7.2 3.8 4.8 0.6 6.5 3.4 6.9 0.7 9.1 4.6 154 0 155 165 0.8 0 1.1 0.7 01/12/2007 00:20:00 5.5 0.3 6.1 4.2 5.2 0.4 6.1 3.4 7.2 0.5 8.4 6.1 154 0 154 165 0.8 0 0.9 0.7 01/12/2007 00:30:00 5.5 0.5 6.5 4.2 5.4 0.6 6.8 3.4 6.8 0.6 8 5.3 154 0 154 165 0.8 0 0.9 0.7 01/12/2007 00:40:00 6.8 0.7 8.4 4.9 7.3 0.9 8.8 5.3 8.1 1 9.9 6.1 154 0 154 165 0.9 0 1.1 0.9 01/12/2007 00:50:00 6.5 0.4 7.2 5.3 6.3 0.5 7.2 4.6 7 0.6 8.4 4.6 154 0 154 165 0.9 0 1.4 0.9 01/12/2007 01:00:00 6.3 0.7 7.6 4.6 5.9 0.6 6.8 4.6 6.4 0.9 8 4.2 154 0 155 165 0.8 0 0.9 0.7 01/12/2007 01:10:00 5.2 0.6 6.1 3.4 5.1 0.5 6.1 3.4 5.2 0.7 6.5 3.4 154 0 154 165 0.8 0 0.9 0.7 01/12/2007 01:20:00 4.5 0.4 5.7 3.4 4.7 0.6 5.7 3 3.8 0.6 4.9 1.9 154 0 154 165 0.8 0 0.9 0.7 01/12/2007 01:30:00 4.5 0.5 5.7 3 4.8 0.6 6.1 3.4 3.1 0.5 3.8 1.9 154 0 154 165 0.9 0 1.1 0.9 01/12/2007 01:40:00 4.3 0.5 5.7 3 4.8 0.6 6.1 3 2.8 0.4 3.8 1.9 154 0 155 165 1 0 1.1 0.9 01/12/2007 01:50:00 4.1 0.4 4.9 2.6 1.4 1.9 5.3 0.4 2.6 0.4 3.4 1.9 154 0 154 165 0.9 0 1.4 0.9 01/12/2007 02:00:00 4.1 0.4 4.9 3.4 0.4 0 0.4 0.4 2.5 0.4 3.4 1.5 154 0 154 165 0.9 0 1.1 0.9 01/12/2007 02:10:00 3.8 0.4 4.6 2.3 0.4 0 0.4 0.4 2.4 0.4 3 1.5 154 0 155 165 0.8 0 0.9 0.7 01/12/2007 02:20:00 3.4 0.5 4.6 2.3 0.4 0 0.4 0.4 0.4 0.3 3 0.4 154 0 154 165 0.8 0 1.1 0.7 01/12/2007 02:30:00 3 0.5 3.8 1.1 0.4 0 0.4 0.4 0.4 0 0.4 0.4 154 0 154 165 0.8 0 0.9 0.7 01/12/2007 02:40:00 1 0.8 2.6 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 154 0 154 165 0.7 0 0.9 0.7 01/12/2007 02:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 154 0 165 165 0.6 0 0.9 0.7 01/12/2007 03:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 154 0 165 165 0.7 0 0.9 0.4 01/12/2007 03:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 154 0 165 165 0.6 0 0.9 0.4 01/12/2007 03:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 154 0 165 165 0.7 0 0.9 0.7 01/12/2007 03:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 154 0 165 165 0.7 0 0.9 0.4 01/12/2007 03:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 154 0 165 165 0.5 0 0.7 0.4 01/12/2007 03:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 154 0 165 165 0.6 0 0.9 0.4 01/12/2007 04:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 154 0 165 165 0.7 0 0.9 0.7 01/12/2007 04:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 154 0 165 165 0.7 0 0.9 0.4 01/12/2007 04:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 154 0 165 165 0.6 0 0.9 0.4 01/12/2007 04:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 154 0 165 165 0.5 0 0.7 0.4 01/12/2007 04:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 154 0 165 165 0.5 0 0.7 0.4 01/12/2007 04:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 154 0 165 165 0.5 0 0.7 0.4 01/12/2007 05:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 154 0 165 165 0.6 0 0.9 0.4 01/12/2007 05:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 154 0 165 165 0.7 0 0.9 0.7 01/12/2007 05:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 154 0 165 165 0.7 0 0.9 0.7 01/12/2007 05:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 154 0 165 165 0.7 0 0.9 0.7 01/12/2007 05:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 154 0 165 165 0.8 0 0.9 0.7 01/12/2007 05:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 154 0 165 165 0.8 0 0.9 0.7 01/12/2007 06:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 154 0 165 165 0.8 0 0.9 0.7 01/12/2007 06:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 154 0 165 165 0.8 0 0.9 0.7 01/12/2007 06:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 154 0 165 165 0.8 0 1.1 0.9 01/12/2007 06:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 154 0 165 165 0.8 0 0.9 0.7 01/12/2007 06:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 154 0 165 165 0.7 0 0.9 0.7 01/12/2007 06:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 154 0 165 165 0.7 0 0.9 0.4 01/12/2007 07:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 154 0 165 165 0.5 0 0.7 0.2 01/12/2007 07:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 154 0 165 165 0.5 0 0.7 0.2 01/12/2007 07:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 154 0 165 165 0.3 0 0.7 0.2 01/12/2007 07:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 154 0 165 165 0.4 0 0.7 0.2 01/12/2007 07:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 154 0 165 165 0.5 0 0.7 0.2 01/12/2007 07:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 154 0 165 165 0.4 0 0.7 0.2 01/12/2007 08:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 154 0 165 165 0.5 0 0.7 0.2 01/12/2007 08:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 154 0 165 165 0.5 0 0.7 0.4 01/12/2007 08:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 154 0 165 165 0.6 0 0.9 0.4 01/12/2007 08:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 154 0 165 165 0.6 0 0.7 0.4 01/12/2007 08:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 154 0 165 165 0.5 0 0.7 0.4 01/12/2007 08:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 154 0 165 165 0.5 0 0.7 0.4 01/12/2007 09:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 154 0 165 165 0.5 0 0.7 0.2 01/12/2007 09:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 154 0 165 165 0.2 0 0.7 0.2 01/12/2007 09:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 154 0 165 165 0.2 0 0.2 -0.1 01/12/2007 09:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 154 0 165 165 0 0 0.2 -0.1 01/12/2007 09:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 154 0 165 165 -0.1 0 0.2 -0.1 01/12/2007 09:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 154 0 165 165 -0.1 0 0.2 -0.1 01/12/2007 10:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 154 0 165 165 0.1 0 0.2 -0.1 01/12/2007 10:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 154 0 165 165 0.2 0 0.7 0.2 01/12/2007 10:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 154 0 165 165 0.3 0 0.7 0.2 01/12/2007 10:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 154 0 165 165 0.2 0 0.4 0.2 01/12/2007 10:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 154 0 165 165 0.2 0 0.4 0.2 01/12/2007 10:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 154 0 165 165 0.1 0 0.2 -0.1 01/12/2007 11:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 154 0 165 165 0.1 0 0.2 -0.1 01/12/2007 11:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 154 0 165 165 0.2 0 0.2 -0.1 01/12/2007 11:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 154 0 165 165 0.2 0 0.4 -0.1 01/12/2007 11:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 154 0 165 165 0.2 0 0.4 0.2 01/12/2007 11:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 154 0 165 165 0.2 0 0.4 0.2 01/12/2007 11:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 154 0 165 165 0.3 0 0.7 0.2 01/12/2007 12:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 154 0 165 165 0.2 0 0.7 0.2 01/12/2007 12:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 154 0 165 165 0.2 0 0.7 0.2 01/12/2007 12:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 154 0 165 165 0.5 0 0.7 0.2 01/12/2007 12:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 154 0 165 165 0.5 0 0.9 0.4 01/12/2007 12:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 154 0 165 165 0.5 0 0.7 0.2 01/12/2007 12:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 154 0 165 165 0.5 0 0.7 0.2 01/12/2007 13:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 154 0 165 165 0.6 0 0.9 0.4 01/12/2007 13:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 154 0 165 165 0.8 0.1 1.1 0.7 01/12/2007 13:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 154 0 165 165 0.9 0 1.1 0.9 01/12/2007 13:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 154 0 165 165 1.1 0 1.4 0.9 01/12/2007 13:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 154 0 165 165 1.2 0 1.4 0.9 01/12/2007 13:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 154 0 165 165 1.2 0 1.4 0.9 01/12/2007 14:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 154 0 165 165 1.1 0 1.4 0.9 01/12/2007 14:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 154 0 165 165 1.1 0 1.4 0.9 01/12/2007 14:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 154 0 165 165 1.1 0 1.4 0.9 01/12/2007 14:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 154 0 165 165 1.1 0 1.4 0.9 01/12/2007 14:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 154 0 165 165 1.1 0 1.4 0.9 01/12/2007 14:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 154 0 165 165 1.2 0 1.4 0.9 01/12/2007 15:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 154 0 165 165 1.2 0 1.4 1.1 01/12/2007 15:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 154 0 165 165 1.2 0 1.4 0.9 01/12/2007 15:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 154 0 165 165 1.1 0 1.4 0.9 01/12/2007 15:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 154 0 165 165 1.2 0 1.6 0.9 01/12/2007 15:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 154 0 165 165 1.4 0 1.6 1.4 01/12/2007 15:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 154 0 165 165 1.4 0 1.6 1.4 01/12/2007 16:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 154 0 165 165 1.5 0 1.6 1.4 01/12/2007 16:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 154 0 165 165 1.5 0 1.6 1.4 01/12/2007 16:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 154 0 165 165 1.5 0 1.6 1.4 01/12/2007 16:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 154 0 165 165 1.5 0 1.6 1.4 01/12/2007 16:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 154 0 165 165 1.5 0 1.6 1.4 01/12/2007 16:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 154 0 165 165 1.5 0 1.6 1.4 01/12/2007 17:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 154 0 165 165 1.6 0 1.8 1.4 01/12/2007 17:10:00 3.7 2.5 6.5 0.4 3.2 2.2 6.1 0.4 0.4 0 0.4 0.4 151 39 173 165 1.9 0.1 2.1 1.6 01/12/2007 17:20:00 5.5 0.5 6.5 4.2 5.1 0.6 6.5 3.8 2.2 1.5 4.9 0.4 133 51 128 165 2.1 0 2.3 1.8 01/12/2007 17:30:00 4.9 0.6 6.1 3.4 5.2 0.6 6.8 3.8 3.6 0.5 4.9 2.3 147 49 166 165 2.3 0 2.6 2.1 01/12/2007 17:40:00 4.7 0.5 6.1 3.4 5.5 0.5 6.8 4.6 4.8 0.7 6.5 3 142 53 172 165 2.4 0 2.6 2.3 01/12/2007 17:50:00 4.5 0.7 6.5 3 6.1 0.6 7.2 4.6 6 0.5 7.2 4.6 149 51 176 165 2.4 0 2.6 2.3 01/12/2007 18:00:00 3.5 0.5 5.7 2.3 5.9 0.6 7.2 4.2 6.3 0.6 7.6 4.6 150 47 77 165 2.4 0 2.6 2.3 01/12/2007 18:10:00 3.1 0.8 5.3 1.5 5.1 1 7.6 3 5.4 1.1 7.6 3.4 178 19 186 165 2.4 0 2.6 2.3 01/12/2007 18:20:00 5.3 0.6 7.2 3.8 7.6 0.4 8 5.7 7.9 0.5 8.8 6.5 188 13 190 165 2.3 0 2.6 2.1 01/12/2007 18:30:00 5 0.6 6.8 3.8 7.7 0.3 8.4 6.5 7.9 0.4 8.8 6.8 186 15 180 165 2.1 0 2.3 1.8 01/12/2007 18:40:00 5.3 0.5 7.2 3.8 7.7 0.3 8.4 6.1 8.1 0.4 8.8 6.8 186 20 181 165 2.1 0 2.3 1.8 01/12/2007 18:50:00 5.3 0.5 6.8 3.8 7.7 0.4 8.4 6.1 7.9 0.4 8.8 6.8 188 18 194 165 2.1 0 2.3 1.8 01/12/2007 19:00:00 5.1 0.6 6.5 3.8 7.5 0.5 8.4 5.7 7.8 0.4 8.8 6.5 187 14 187 165 2.1 0 2.3 1.8 01/12/2007 19:10:00 4.8 0.5 6.1 3.4 7.4 0.6 8.4 4.9 7.8 0.4 8.8 5.7 193 8 191 165 2.1 0 2.3 1.8 01/12/2007 19:20:00 4.9 0.5 6.1 3.4 7.4 0.4 8.4 6.1 7.8 0.3 8.4 7.2 193 7 194 165 2 0 2.3 1.8 01/12/2007 19:30:00 4.7 0.5 5.7 3.4 7.2 0.6 8 4.9 7.6 0.4 8.4 5.7 192 10 205 165 1.9 0 2.1 1.8 01/12/2007 19:40:00 3.6 0.6 5.3 2.6 5.8 0.9 8 3.8 6.3 0.9 8.4 4.2 202 9 201 165 2 0 2.1 1.8 01/12/2007 19:50:00 3.7 0.4 4.9 2.6 6 0.7 7.6 4.6 6.7 0.7 8 4.6 201 8 203 165 2 0 2.3 1.8 01/12/2007 20:00:00 2.8 0.5 3.8 1.5 4.7 0.9 6.5 2.6 4.9 0.9 6.8 2.6 210 10 192 165 1.9 0 2.3 1.8 01/12/2007 20:10:00 3.3 0.5 4.6 2.3 5.6 0.8 7.2 3 5.9 0.8 7.6 3.8 208 10 209 165 1.9 0 2.1 1.8 01/12/2007 20:20:00 3.3 0.5 4.9 2.3 5.5 0.9 7.2 3 6.1 1 8 3.4 200 9 196 165 1.9 0 2.1 1.8 01/12/2007 20:30:00 2.8 0.5 4.2 1.9 4.5 1 6.8 2.3 5.1 1 7.6 3 198 18 207 165 1.8 0 1.8 1.6 01/12/2007 20:40:00 2.1 0.7 3.4 0.4 3.1 1.1 6.1 0.4 3.8 1.2 6.5 0.4 201 15 185 165 1.7 0 1.8 1.6 01/12/2007 20:50:00 0.4 0 0.4 0.4 0.7 0.8 3.4 0.4 0.7 0.9 4.6 0.4 282 51 165 165 1.6 0 1.8 1.4 01/12/2007 21:00:00 0.4 0 0.4 0.4 0.4 0.3 2.3 0.4 0.9 1 4.2 0.4 313 61 165 165 1.5 0 1.8 1.4 01/12/2007 21:10:00 1.6 1.3 4.6 0.4 3.6 1.7 7.2 0.4 4 1.7 7.2 0.4 204 21 198 165 2 0 2.3 1.6 01/12/2007 21:20:00 3 0.5 4.6 1.9 5 0.9 6.8 2.6 5.5 1 8 3 205 11 204 165 2.3 0 2.6 1.8 01/12/2007 21:30:00 2.8 0.5 4.6 1.5 4.9 0.8 6.5 3 5.3 0.9 7.2 3.4 208 10 212 165 2.4 0.1 2.6 1.8 01/12/2007 21:40:00 2.8 0.4 4.2 1.9 4.8 0.8 6.5 2.3 5.4 0.8 7.2 3 207 8 204 165 2.4 0.1 2.6 1.8 01/12/2007 21:50:00 1.7 1 3.4 0.4 3.3 1.2 5.3 0.4 3.8 1.3 6.5 0.4 208 9 212 165 2.2 0 2.6 1.8 01/12/2007 22:00:00 1 0.8 3 0.4 2.8 1 4.9 0.4 3.5 1 5.7 1.5 212 11 214 165 2.3 0 2.6 2.1 01/12/2007 22:10:00 0.5 0.3 1.9 0.4 1.4 0.7 2.6 0.4 2 0.5 3 0.7 235 12 240 165 2.2 0 2.6 1.8 01/12/2007 22:20:00 0.4 0 0.4 0.4 0.6 0.5 2.6 0.4 0.9 0.8 3 0.4 239 12 165 165 2.4 0 2.6 2.3 01/12/2007 22:30:00 0.4 0.1 1.1 0.4 1.8 1.1 3.8 0.4 2.2 1.3 4.6 0.4 260 12 245 165 2.4 0 2.6 2.3 01/12/2007 22:40:00 0.4 0.1 0.7 0.4 3.1 0.9 4.6 0.4 3.7 0.7 4.9 1.1 266 8 260 165 2.3 0 2.6 2.1 01/12/2007 22:50:00 0.4 0 0.7 0.4 3.7 0.6 5.3 2.3 4.2 0.6 5.3 2.6 267 5 257 165 2.3 0 2.6 2.1 01/12/2007 23:00:00 0.4 0 0.4 0.4 3.6 0.5 4.6 2.3 3.9 0.7 5.3 2.3 278 5 165 165 2 0.1 2.3 1.8 01/12/2007 23:10:00 0.4 0 0.4 0.4 5 0.6 6.5 3 5.5 0.7 7.6 3.8 281 5 165 165 1.8 0 2.3 1.6 01/12/2007 23:20:00 0.4 0 0.7 0.4 5.4 0.5 6.8 4.2 6.1 0.6 7.6 4.2 281 6 280 165 1.5 0.1 1.8 1.4 01/12/2007 23:30:00 0.4 0 0.4 0.4 4 0.6 5.3 2.6 4.3 0.9 6.1 1.9 285 5 165 165 1.3 0 1.6 0.9 01/12/2007 23:40:00 0.4 0 0.4 0.4 4.6 0.5 6.1 3 5 0.7 6.1 2.6 285 5 165 165 1.2 0 1.4 0.9 01/12/2007 23:50:00 0.4 0 0.4 0.4 3.3 0.7 4.9 1.5 3.5 0.7 5.7 2.3 282 5 165 165 1 0 1.4 0.9 01/13/2007 00:00:00 0.4 0 0.4 0.4 3.1 1 4.9 1.5 3.4 1.1 6.1 1.1 280 7 165 165 0.9 0 1.1 0.9 01/13/2007 00:10:00 0.4 0 0.4 0.4 2.8 0.7 4.9 1.1 3.1 0.7 4.9 1.1 278 7 165 165 0.9 0 1.4 0.9 01/13/2007 00:20:00 0.4 0 0.4 0.4 3.4 0.5 4.6 1.9 3.5 0.6 4.9 1.5 277 7 165 165 0.9 0 1.4 0.9 01/13/2007 00:30:00 0.4 0 0.4 0.4 2.9 0.5 3.8 1.5 3.2 0.5 4.2 1.5 276 8 165 165 0.8 0 0.9 0.7 01/13/2007 00:40:00 0.4 0 0.4 0.4 3.2 0.3 3.8 2.3 3.5 0.4 4.2 2.3 280 5 165 165 0.8 0 0.9 0.7 01/13/2007 00:50:00 0.4 0 0.4 0.4 3.1 0.3 3.8 2.6 3.8 0.3 4.6 3 283 3 165 165 0.8 0 1.1 0.7 01/13/2007 01:00:00 0.4 0 0.4 0.4 3.4 0.5 4.6 2.3 3.9 0.6 5.3 2.3 281 5 165 165 1.1 0 1.4 0.9 01/13/2007 01:10:00 0.4 0 0.4 0.4 2.9 0.3 3.4 2.3 3.4 0.4 4.2 1.9 271 6 165 165 1 0 1.1 0.9 01/13/2007 01:20:00 0.4 0 0.4 0.4 3.2 0.4 4.2 2.3 3.8 0.4 4.6 3 273 3 165 165 0.9 0 1.1 0.9 01/13/2007 01:30:00 0.4 0 0.4 0.4 2.8 0.5 3.8 1.5 2.9 0.6 4.6 1.9 283 7 165 165 0.8 0.1 1.1 0.7 01/13/2007 01:40:00 0.4 0 0.4 0.4 2.4 0.3 3 1.5 3 0.3 3.8 2.3 270 4 165 165 0.8 0 1.1 0.7 01/13/2007 01:50:00 0.4 0 0.4 0.4 3 0.4 3.8 1.9 3.5 0.4 4.6 2.6 265 2 165 165 0.9 0 1.4 0.9 01/13/2007 02:00:00 0.4 0 0.4 0.4 1.5 1.1 3.4 0.4 2 1.1 3.8 0.4 285 20 165 165 0.9 0.1 1.4 0.7 01/13/2007 02:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 300 7 165 165 0.5 0 0.9 0.4 01/13/2007 02:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 286 7 165 165 0.7 0 1.1 0.4 01/13/2007 02:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.7 0.4 282 5 165 165 0.9 0 1.1 0.9 01/13/2007 02:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 1.6 1 3 0.4 290 4 165 165 0.8 0 1.1 0.7 01/13/2007 02:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 2.1 0.4 3 1.1 287 6 165 165 0.6 0 0.9 0.4 01/13/2007 03:00:00 0.6 0.6 2.6 0.4 1.8 1 3.4 0.4 3.1 0.4 4.2 2.3 263 7 252 165 0.8 0 1.1 0.7 01/13/2007 03:10:00 0.4 0 0.4 0.4 1.9 0.5 3 0.7 2.8 0.4 3.8 1.1 261 4 165 165 0.8 0 1.1 0.7 01/13/2007 03:20:00 0.4 0 0.4 0.4 1.6 0.8 2.6 0.4 2.8 0.6 3.8 1.5 257 5 165 165 0.8 0 1.1 0.7 01/13/2007 03:30:00 0.4 0 0.4 0.4 0.5 0.3 1.9 0.4 1.6 0.6 3 0.4 268 4 165 165 0.8 0 0.9 0.7 01/13/2007 03:40:00 0.4 0 0.4 0.4 0.4 0 0.7 0.4 0.4 0 1.1 0.4 294 8 165 165 0.8 0 1.1 0.7 01/13/2007 03:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 297 5 165 165 0.5 0 0.9 0.2 01/13/2007 04:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 278 12 165 165 0.7 0.1 0.9 0.4 01/13/2007 04:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 248 9 165 165 0.8 0 0.9 0.9 01/13/2007 04:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 275 8 165 165 0.8 0 0.9 0.7 01/13/2007 04:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 240 9 165 165 0.8 0 1.1 0.7 01/13/2007 04:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 252 8 165 165 0.8 0 0.9 0.7 01/13/2007 04:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 255 13 165 165 0.6 0 0.9 0.4 01/13/2007 05:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 228 7 165 165 0.7 0 0.9 0.7 01/13/2007 05:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 239 10 165 165 0.8 0.1 0.9 0.7 01/13/2007 05:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 234 11 165 165 0.9 0 1.4 0.9 01/13/2007 05:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 302 16 165 165 0.4 0.4 1.4 -0.3 01/13/2007 05:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 246 45 165 165 0.1 0.2 0.7 -0.3 01/13/2007 05:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 186 6 165 165 0.5 0.1 0.9 0.2 01/13/2007 06:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 305 24 165 165 0.1 0 0.4 -0.1 01/13/2007 06:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 318 0 165 165 0 0 0.2 -0.1 01/13/2007 06:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 346 8 165 165 0.1 0 0.2 -0.1 01/13/2007 06:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 349 4 165 165 -0.2 0 -0.1 -0.3 01/13/2007 06:40:00 0.4 0.1 0.7 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 33 12 27 165 -0.2 0.1 0.2 -0.5 01/13/2007 06:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 41 8 165 165 0.1 0 0.2 -0.3 01/13/2007 07:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 1.3 0.6 2.3 0.4 33 8 165 165 -0.2 0 -0.1 -0.3 01/13/2007 07:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 2.6 0.8 3.8 0.7 27 9 165 165 -0.2 0.2 0.2 -0.8 01/13/2007 07:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 2.7 0.2 3.4 2.3 20 4 165 165 -0.9 0.1 -0.5 -1 01/13/2007 07:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 2.1 0.2 2.6 1.5 17 2 165 165 -0.9 0 -0.5 -1 01/13/2007 07:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 1 0.5 1.9 0.4 27 6 165 165 -0.4 0.1 -0.1 -0.8 01/13/2007 07:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.8 0.6 1.9 0.4 34 9 165 165 -0.3 0 -0.1 -0.5 01/13/2007 08:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.6 0.4 1.9 0.4 38 10 165 165 -0.3 0.2 0.2 -0.5 01/13/2007 08:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 42 12 165 165 0.3 0.1 0.7 -0.1 01/13/2007 08:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 50 16 165 165 -0.1 0.1 0.2 -0.3 01/13/2007 08:30:00 0.4 0.1 0.7 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 98 20 87 165 0 0 0.4 -0.1 01/13/2007 08:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 42 12 165 165 -0.2 0 -0.1 -0.3 01/13/2007 08:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 27 2 165 165 -0.3 0 -0.1 -0.5 01/13/2007 09:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 31 2 165 165 -0.1 0.2 0.4 -0.3 01/13/2007 09:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 32 2 165 165 0.2 0.1 0.7 -0.1 01/13/2007 09:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 33 3 165 165 -0.2 0 0.2 -0.3 01/13/2007 09:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 45 6 165 165 0.2 0.2 0.7 -0.3 01/13/2007 09:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 45 7 165 165 0.3 0.1 0.7 -0.1 01/13/2007 09:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 1.1 0.9 2.6 0.4 30 3 165 165 0 0 0.2 -0.3 01/13/2007 10:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 2.7 0.3 3.4 1.9 27 3 165 165 -0.1 0 0.2 -0.3 01/13/2007 10:10:00 0.6 0.6 2.3 0.4 0.9 1 3.4 0.4 2.7 0.6 3.8 1.5 29 4 28 165 -0.1 0 0.2 -0.3 01/13/2007 10:20:00 1.6 0.3 2.3 0.7 2.3 0.4 3 1.1 3.2 0.4 3.8 2.3 23 4 22 165 -0.1 0 0.2 -0.3 01/13/2007 10:30:00 2.1 0.3 3 1.5 2.9 0.3 3.4 1.9 3.7 0.4 4.6 2.6 22 3 23 165 -0.2 0.1 0.2 -0.3 01/13/2007 10:40:00 2.1 0.3 3 1.5 1.8 0.9 3.4 0.4 3.8 0.3 4.6 3 13 4 10 165 -0.3 0 -0.1 -0.3 01/13/2007 10:50:00 2.3 0.3 3 1.5 2.4 1.2 3.8 0.4 4.1 0.4 4.9 3.4 17 6 21 165 -0.3 0 -0.1 -0.5 01/13/2007 11:00:00 2.4 0.3 3 1.9 3.1 0.3 3.8 2.6 4.1 0.3 4.9 3.4 22 3 20 165 -0.1 0 0.2 -0.3 01/13/2007 11:10:00 2.3 0.2 3 1.9 3.1 0.3 3.8 2.6 4 0.3 4.6 3.4 28 3 29 165 -0.1 0 0.2 -0.3 01/13/2007 11:20:00 3 0.3 3.8 2.3 3.6 0.4 4.6 2.6 4.7 0.4 5.7 3.8 21 6 23 165 -0.1 0 0.2 -0.1 01/13/2007 11:30:00 2.8 0.3 3.4 2.3 3.3 0.4 4.6 1.9 4.5 0.3 5.3 3.8 18 3 7 165 -0.1 0 0.2 -0.1 01/13/2007 11:40:00 2.7 0.3 3.4 1.9 3.1 0.4 4.2 1.5 4.4 0.4 5.7 3.4 16 3 16 165 -0.1 0 0.2 -0.1 01/13/2007 11:50:00 2.7 0.2 3.4 2.3 3.3 0.4 4.2 2.3 4.1 0.4 4.9 3.4 20 3 21 165 0 0 0.2 -0.1 01/13/2007 12:00:00 3.2 0.3 3.8 2.3 4.1 0.3 4.9 3 4.8 0.4 5.7 3.8 22 3 19 165 0.1 0 0.2 -0.1 01/13/2007 12:10:00 4.1 0.4 5.3 3.4 4 0.9 6.5 1.9 5.9 0.5 7.2 4.6 13 4 18 165 0.1 0 0.2 -0.1 01/13/2007 12:20:00 4.4 0.3 4.9 3.8 4.1 0.6 5.3 2.3 6.2 0.4 7.2 4.9 12 3 10 165 0.1 0 0.2 -0.1 01/13/2007 12:30:00 4.2 0.3 4.9 3.4 4.3 0.7 5.7 1.9 6.1 0.4 6.8 4.9 13 3 11 165 0.2 0.1 0.7 -0.1 01/13/2007 12:40:00 3.8 0.4 4.6 3 3.6 0.9 5.3 1.5 5.5 0.4 6.8 4.6 13 5 19 165 0.3 0 0.7 0.2 01/13/2007 12:50:00 4 0.4 4.9 3 3.2 1 5.3 0.7 5.6 0.5 6.8 4.6 10 5 14 165 0.4 0 0.7 0.2 01/13/2007 13:00:00 3.7 0.4 4.9 2.6 3.6 0.8 5.3 1.5 5.3 0.5 6.5 4.2 13 6 7 165 0.3 0 0.7 0.2 01/13/2007 13:10:00 4.1 0.4 5.3 3 4.3 0.8 6.1 1.9 5.8 0.6 7.2 4.2 15 6 16 165 0.3 0 0.7 0.2 01/13/2007 13:20:00 3.5 0.5 4.9 2.3 3.9 0.7 5.7 1.5 5.1 0.6 6.8 3.8 18 5 18 165 0.2 0 0.4 0.2 01/13/2007 13:30:00 4 0.6 5.3 2.3 4.2 0.9 6.5 1.9 5.6 0.7 7.2 4.2 15 6 10 165 0.2 0 0.4 0.2 01/13/2007 13:40:00 4.1 0.5 5.3 2.6 3.9 0.9 6.1 1.9 5.7 0.6 7.2 3.8 12 5 16 165 0.2 0 0.2 -0.1 01/13/2007 13:50:00 4.5 0.4 5.7 3.4 3.5 0.8 5.3 1.5 6.1 0.5 7.2 4.2 8 6 360 165 0.2 0 0.7 0.2 01/13/2007 14:00:00 5.1 0.5 6.1 3.8 3.6 0.9 5.7 1.9 6.8 0.6 8.4 5.3 6 7 6 165 0.5 0 0.9 0.2 01/13/2007 14:10:00 5 0.5 6.1 3.8 3.5 1 6.5 1.5 6.8 0.6 8 5.3 4 7 360 165 0.5 0.1 0.9 0.2 01/13/2007 14:20:00 6.5 0.8 8.4 4.2 3.7 0.9 6.1 1.9 7.2 0.7 8.8 5.7 2 6 9 165 0.3 0 0.7 0.2 01/13/2007 14:30:00 7.1 0.7 8.8 5.3 4.6 1 7.2 2.3 7.5 0.7 9.1 5.7 4 8 10 165 0.3 0 0.7 0.2 01/13/2007 14:40:00 6.9 0.6 8.4 5.3 5.2 0.9 7.2 2.6 7.4 0.6 9.1 5.3 7 9 356 165 0.3 0 0.7 0.2 01/13/2007 14:50:00 6.5 0.6 7.6 4.6 5.4 1 7.6 2.6 6.9 0.6 8.4 4.9 11 9 1 165 0.3 0 0.7 0.2 01/13/2007 15:00:00 6.5 0.8 8.4 4.9 5.4 1.1 8.4 3 6.9 0.7 9.1 4.9 7 12 6 165 0.2 0 0.4 0.2 01/13/2007 15:10:00 6.8 0.7 8.4 4.9 5.3 0.9 7.2 3 7.1 0.8 9.1 5.3 5 8 6 165 0.2 0 0.7 0.2 01/13/2007 15:20:00 6.9 0.7 8.4 5.3 5 1 8 3 7.3 0.8 8.8 4.9 4 9 8 165 0.2 0 0.4 0.2 01/13/2007 15:30:00 7.8 0.6 8.8 5.7 5.5 1.1 8.8 3.4 8.1 0.7 9.5 6.1 4 8 6 165 0.2 0 0.4 0.2 01/13/2007 15:40:00 7.2 0.6 8.8 4.9 5.1 1 8 3 7.7 0.6 9.1 6.1 3 8 3 165 0.2 0 0.7 0.2 01/13/2007 15:50:00 7.2 0.9 8.8 4.6 5.1 1.3 8.4 2.3 7.5 0.9 9.1 5.3 2 10 14 165 0.2 0 0.7 0.2 01/13/2007 16:00:00 7.5 0.7 8.8 5.3 5.4 1.1 8 3 7.8 0.8 9.1 5.3 3 10 6 165 0.2 0 0.4 0.2 01/13/2007 16:10:00 7 0.7 8.4 5.3 4.7 1.1 8 2.3 7.4 0.8 9.1 5.3 2 9 350 165 0.2 0 0.4 0.2 01/13/2007 16:20:00 7.2 0.9 8.8 4.9 4.9 1.5 8.4 2.3 7.6 0.8 9.5 5.3 359 10 15 165 0.2 0 0.4 0.2 01/13/2007 16:30:00 7.1 0.7 8.4 5.7 5 1.1 8 2.6 7.4 0.8 9.1 5.3 357 7 7 165 0.2 0 0.7 0.2 01/13/2007 16:40:00 7.2 0.9 8.8 4.9 5.4 1.4 8.8 2.3 7.5 0.8 9.1 5.3 358 10 352 165 0.3 0 0.7 0.2 01/13/2007 16:50:00 6.6 1.1 9.1 3.4 4.7 1.3 8.4 1.9 7 1 9.5 4.2 358 9 4 165 0.3 0 0.7 0.2 01/13/2007 17:00:00 7.5 0.8 8.8 5.3 5.7 1.4 9.1 2.6 7.8 0.9 9.5 5.3 357 10 354 165 0.4 0 0.7 0.2 01/13/2007 17:10:00 7.2 0.8 8.8 4.9 5.4 1.3 9.1 2.3 7.5 0.8 9.5 5.3 360 10 354 165 0.4 0 0.7 0.2 01/13/2007 17:20:00 7.7 0.7 9.1 5.7 5.9 1.2 8.8 3 8.1 0.7 9.5 5.7 360 10 12 165 0.5 0 0.7 0.4 01/13/2007 17:30:00 8 0.6 9.1 6.1 6.3 1.4 9.1 3.4 8.4 0.7 9.9 6.5 3 10 12 165 0.6 0 0.9 0.4 01/13/2007 17:40:00 8.1 0.6 9.1 6.1 6.2 1.3 9.1 3 8.5 0.8 9.9 5.7 3 9 353 165 0.5 0 0.7 0.4 01/13/2007 17:50:00 8.1 0.6 9.1 5.7 6.4 1.1 9.1 3.4 8.4 0.6 9.5 6.5 5 9 11 165 0.4 0 0.7 0.2 01/13/2007 18:00:00 8.5 0.4 9.1 6.8 6.7 1.1 9.9 3.8 8.9 0.6 9.9 6.8 3 8 5 165 0.4 0 0.7 0.2 01/13/2007 18:10:00 8.4 0.5 9.1 6.5 7.6 1.2 9.5 3.8 8.7 0.7 9.9 6.8 11 15 4 165 0.5 0 0.9 0.2 01/13/2007 18:20:00 8.5 0.4 9.1 6.8 8.1 1 9.9 4.9 8.9 0.6 9.9 6.8 10 13 350 165 0.4 0 0.7 0.2 01/13/2007 18:30:00 8.5 0.4 9.1 6.5 7.4 1 9.9 4.9 8.9 0.6 9.9 6.8 5 12 8 165 0.5 0 0.7 0.2 01/13/2007 18:40:00 7.4 0.7 8.8 4.9 7 1 8.8 3.8 7.5 0.9 9.1 5.3 15 11 10 165 0.5 0 0.9 0.4 01/13/2007 18:50:00 7.8 0.6 8.8 5.7 7.5 0.9 9.5 4.2 8 0.8 9.5 4.9 15 11 339 165 0.6 0 0.9 0.4 01/13/2007 19:00:00 8.2 0.6 9.1 6.1 8.3 0.8 9.5 6.1 8.6 0.7 9.9 6.1 23 11 32 165 0.8 0 0.9 0.7 01/13/2007 19:10:00 8.2 0.5 9.1 6.1 8.3 0.7 9.5 6.1 8.5 0.7 9.5 6.5 21 12 26 165 0.7 0 0.9 0.7 01/13/2007 19:20:00 8.2 0.6 9.1 5.7 8.3 0.9 9.5 5.3 8.7 0.7 9.9 6.5 16 13 19 165 0.7 0 0.9 0.4 01/13/2007 19:30:00 8.6 0.8 13.3 6.8 8.8 0.5 9.5 6.8 9.1 0.4 9.9 6.8 14 13 7 165 0.5 0 0.9 0.4 01/13/2007 19:40:00 8.4 1 13.3 6.8 8.2 0.8 9.5 4.6 8.7 0.5 9.5 6.5 14 10 23 165 0.5 0 0.7 0.4 01/13/2007 19:50:00 8.1 0.4 8.8 6.5 7.4 1.2 9.1 4.2 8.6 0.5 9.5 6.8 10 7 23 165 0.5 0 0.7 0.2 01/13/2007 20:00:00 8.1 0.3 8.8 6.8 6.9 1.2 9.1 4.2 8.8 0.4 9.5 7.2 5 8 16 165 0.5 0 0.7 0.2 01/13/2007 20:10:00 8 0.3 8.4 6.8 7.3 1 9.1 4.2 8.6 0.4 9.1 7.2 7 9 2 165 0.4 0 0.7 0.2 01/13/2007 20:20:00 8 0.7 12.2 6.5 7.5 1.1 9.1 4.6 8.5 0.5 9.1 7.2 9 11 12 165 0.5 0 0.7 0.2 01/13/2007 20:30:00 8.1 0.5 12.2 7.2 7.7 1 9.5 4.2 8.6 0.4 9.5 6.8 9 8 16 165 0.5 0 0.7 0.2 01/13/2007 20:40:00 7.9 0.4 10.3 6.1 7.5 1.1 9.1 4.2 8.4 0.5 9.1 6.8 12 8 14 165 0.5 0 0.7 0.2 01/13/2007 20:50:00 7.7 0.3 8.4 6.5 7.4 0.9 9.1 4.6 8.3 0.5 9.1 6.8 11 5 12 165 0.5 0 0.7 0.4 01/13/2007 21:00:00 7.7 0.3 8.4 6.5 7.5 1 8.8 4.6 8.3 0.5 9.1 6.1 12 0 12 165 0.5 0 0.7 0.2 01/13/2007 21:10:00 7.7 0.5 12.2 6.5 7.4 1 8.8 4.2 8.2 0.5 8.8 5.7 12 0 12 165 0.5 0 0.7 0.4 01/13/2007 21:20:00 7.7 0.5 11.5 6.5 7.2 1 8.8 3.4 8.2 0.4 8.8 6.5 12 0 12 165 0.5 0 0.9 0.4 01/13/2007 21:30:00 7.5 0.2 8 6.5 7.4 0.9 8.8 4.6 8.1 0.4 8.8 6.8 12 0 12 165 0.5 0 0.7 0.2 01/13/2007 21:40:00 7.4 0.3 8 5.7 7.3 1 8.8 3.8 8 0.4 8.8 6.1 12 0 12 165 0.6 0 0.9 0.4 01/13/2007 21:50:00 7.4 0.3 8 6.1 7.2 1.1 8.8 3.4 7.9 0.5 8.8 6.5 12 0 12 165 0.7 0 0.9 0.7 01/13/2007 22:00:00 7.3 0.3 8 6.1 7.3 0.9 8.4 4.2 8.1 0.5 9.1 6.1 12 0 12 165 0.8 0 0.9 0.7 01/13/2007 22:10:00 7.4 0.7 11.1 6.1 7.1 1 8.8 4.2 8.2 0.5 9.1 6.8 12 0 12 165 0.8 0 0.9 0.7 01/13/2007 22:20:00 7.2 0.4 10.7 6.1 7 1 8.4 3.4 8.1 0.5 9.1 6.1 12 0 12 165 0.8 0 0.9 0.7 01/13/2007 22:30:00 7.3 0.7 10.7 6.1 7.2 0.9 8.8 4.2 8.2 0.5 9.1 6.8 12 0 12 165 0.8 0 0.9 0.7 01/13/2007 22:40:00 7.1 0.3 9.1 6.1 6.9 1 8.4 3.4 8 0.5 8.8 6.5 12 0 12 165 0.8 0 0.9 0.7 01/13/2007 22:50:00 7.3 0.7 11.1 6.1 7 1 8.4 3.4 8 0.4 8.8 6.8 12 0 12 165 0.8 0 0.9 0.7 01/13/2007 23:00:00 7.2 0.7 11.1 4.9 6.8 1.2 8.4 3 8.1 0.4 8.8 6.5 12 0 12 165 0.8 0 1.1 0.7 01/13/2007 23:10:00 7 0.5 10.7 5.7 6.5 1.2 8.4 3 7.7 0.5 8.4 6.5 12 0 12 165 0.8 0 0.9 0.7 01/13/2007 23:20:00 6.9 0.4 7.6 5.3 6 1.5 8.4 3 7.8 0.5 8.8 5.7 12 0 12 165 0.7 0 0.9 0.7 01/13/2007 23:30:00 6.7 0.4 7.2 5.7 4.7 1.3 8 1.9 7.5 0.5 8.8 6.1 12 0 12 165 0.6 0 0.9 0.4 01/13/2007 23:40:00 6.6 0.5 7.6 5.3 4.5 1.5 7.6 1.5 7.5 0.5 8.4 5.7 12 0 12 165 0.5 0 0.7 0.4 01/13/2007 23:50:00 7 0.7 10.3 4.9 5.3 1.4 8 2.6 7.9 0.5 8.8 6.1 12 0 12 165 0.5 0 0.9 0.2 01/14/2007 00:00:00 7.2 0.6 11.1 6.1 5.2 1.3 8 1.9 8 0.3 8.8 6.8 12 0 12 165 0.4 0.1 0.7 0.2 01/14/2007 00:10:00 7.1 0.6 9.9 3.8 5.6 1.2 8.4 2.6 8 0.4 8.8 5.7 12 0 12 165 0.2 0 0.4 0.2 01/14/2007 00:20:00 7.7 1.2 12.2 5.7 5.7 1.3 8.4 2.3 8.1 0.4 8.8 6.5 12 0 12 165 0.2 0 0.4 -0.1 01/14/2007 00:30:00 8.3 1.9 14.5 5.7 6.5 1.2 8.4 3 8.9 1.7 15.6 7.2 12 0 12 165 0 0 0.2 -0.3 01/14/2007 00:40:00 7.9 1.3 11.5 5.7 6.1 1.1 8.4 3 8.3 0.3 8.8 6.8 12 0 12 165 -0.1 0 0.2 -0.3 01/14/2007 00:50:00 7.4 1.4 13.7 5.7 6.1 1.2 9.9 3 8.1 0.4 9.1 6.5 12 0 12 165 -0.2 0 -0.1 -0.3 01/14/2007 01:00:00 7.8 1.6 13 5.7 6.6 1.2 8.4 3 8.3 0.4 9.1 7.2 12 0 12 165 -0.3 0 -0.1 -0.5 01/14/2007 01:10:00 7.4 1 11.8 6.1 7.1 0.9 8.4 3 8.2 0.4 8.8 6.5 12 0 12 165 -0.3 0 -0.3 -0.5 01/14/2007 01:20:00 7.5 1.1 12.2 5.3 7 1 8.4 3.4 8.3 0.3 8.8 7.2 12 0 12 165 -0.3 0 -0.1 -0.5 01/14/2007 01:30:00 8 1.6 13.7 6.1 7.1 1 10.7 4.2 8.5 0.3 9.1 7.2 12 0 12 165 -0.3 0 -0.1 -0.5 01/14/2007 01:40:00 8.2 1.7 13.7 6.1 7.3 1 9.5 4.2 8.5 0.3 9.1 6.8 12 0 12 165 -0.3 0 -0.1 -0.3 01/14/2007 01:50:00 7.5 1.2 13.7 6.5 7.1 0.9 8.8 4.2 8.4 0.4 9.1 7.2 12 0 12 165 -0.3 0 -0.1 -0.5 01/14/2007 02:00:00 7.5 1.2 14.5 5.7 7 1 8.8 3.8 8.3 0.4 9.1 6.8 12 0 12 165 -0.2 0 -0.1 -0.3 01/14/2007 02:10:00 7.9 1.7 15.6 5.7 7.2 1 8.8 4.2 8.5 0.4 9.1 7.2 12 0 12 165 -0.2 0 -0.1 -0.3 01/14/2007 02:20:00 7.2 0.6 12.6 5.3 7.5 0.6 8.8 4.6 8.2 0.4 9.1 6.8 12 0 12 165 -0.3 0 -0.1 -0.3 01/14/2007 02:30:00 7.5 1.1 12.2 6.1 7.5 1 13.3 4.9 8.4 0.4 9.1 6.8 12 0 12 165 -0.2 0 -0.1 -0.3 01/14/2007 02:40:00 7.6 1.1 12.2 5.3 7.4 0.9 9.1 4.6 8.5 0.4 9.1 6.8 12 0 11 165 -0.1 0 0.2 -0.3 01/14/2007 02:50:00 7.5 1.1 12.2 5.7 7.3 0.7 8.4 4.6 8.3 0.4 9.1 6.8 12 0 12 165 -0.1 0 0.2 -0.3 01/14/2007 03:00:00 7.8 1.7 16.1 5.7 7.6 1.2 14.9 4.6 8.5 0.4 9.1 7.6 12 0 12 165 0.1 0 0.2 -0.1 01/14/2007 03:10:00 8 1.7 15.3 5.7 7.6 0.6 9.1 5.3 8.9 1.5 16.4 7.2 11 0 11 165 0.2 0 0.4 -0.1 01/14/2007 03:20:00 7.1 1.2 13 4.6 6.7 0.9 8.8 4.2 8.2 0.5 9.1 6.5 11 0 12 165 0.1 0 0.7 -0.1 01/14/2007 03:30:00 6.6 1 11.1 4.2 6.6 1 8.4 4.2 7.8 0.8 9.1 4.9 12 0 11 165 0.1 0 0.2 -0.1 01/14/2007 03:40:00 7 1.3 12.2 4.9 7.1 0.8 8.8 4.9 8.1 0.6 9.1 5.7 11 0 11 165 0 0 0.2 -0.1 01/14/2007 03:50:00 6.6 0.9 11.1 4.6 7 0.9 11.1 4.6 7.9 0.8 9.1 5.3 11 0 11 165 -0.2 0 0.2 -0.3 01/14/2007 04:00:00 6.9 0.6 9.1 4.6 7.4 0.6 8.4 5.3 8.2 0.6 9.1 5.7 11 0 11 165 -0.3 0 -0.1 -0.5 01/14/2007 04:10:00 7.2 0.8 11.1 5.3 7.5 0.6 9.1 5.7 8.3 0.5 9.1 6.8 11 0 11 165 -0.5 0 -0.3 -0.8 01/14/2007 04:20:00 7.5 1.1 12.2 5.7 7.8 0.5 8.8 5.7 8.7 0.5 13.3 7.6 11 0 11 165 -0.4 0 -0.3 -0.5 01/14/2007 04:30:00 7.2 1 12.6 4.6 7.5 0.8 8.8 4.9 8.2 0.9 15.6 6.1 11 0 11 165 -0.4 0 -0.1 -0.8 01/14/2007 04:40:00 7.2 0.8 11.5 5.3 7.5 0.7 9.1 4.6 8.4 0.5 9.1 6.8 11 0 11 165 -0.6 0 -0.3 -0.8 01/14/2007 04:50:00 7.9 1.7 13.3 5.7 7.9 1.1 13.7 4.6 9.1 2 18.7 6.8 11 0 11 165 -0.6 0 -0.3 -0.8 01/14/2007 05:00:00 7.5 0.9 11.8 5.3 7.7 0.5 9.1 5.7 8.6 0.4 9.1 7.6 11 0 11 165 -0.6 0 -0.5 -0.8 01/14/2007 05:10:00 7.7 1 12.2 6.1 7.9 0.5 9.1 6.5 8.7 0.6 13.7 6.5 11 0 11 165 -0.6 0 -0.5 -0.8 01/14/2007 05:20:00 8.1 1.4 16.1 6.1 8.2 0.8 14.1 6.1 9.2 1.5 16.4 7.2 351 22 295 165 -0.7 0 -0.5 -0.8 01/14/2007 05:30:00 7.6 0.8 11.8 6.1 8 0.4 9.1 6.8 8.7 0.3 9.1 7.2 316 9 304 165 -0.7 0 -0.5 -0.8 01/14/2007 05:40:00 7.7 1.1 13 5.7 8 0.5 8.8 6.1 8.6 0.4 9.5 7.2 322 14 295 165 -0.7 0 -0.5 -0.8 01/14/2007 05:50:00 7.4 0.6 11.5 5.3 7.9 0.5 8.8 6.5 8.6 0.5 9.1 6.1 320 11 302 165 -0.7 0 -0.5 -0.8 01/14/2007 06:00:00 7.9 1.5 13 5.7 7.9 0.6 9.1 6.1 8.6 0.5 9.1 6.1 320 11 339 165 -0.8 0 -0.5 -0.8 01/14/2007 06:10:00 7.3 0.9 12.6 5.3 7.6 0.6 9.1 5.7 8.4 0.7 9.1 5.3 318 12 307 165 -0.8 0.1 -0.5 -0.8 01/14/2007 06:20:00 7.4 1.2 14.1 4.9 7.7 1.1 13.3 4.9 8.6 1.5 16.1 5.7 323 13 349 165 -0.7 0.1 -0.5 -0.8 01/14/2007 06:30:00 7.5 1 12.6 5.3 7.9 0.6 9.1 6.1 8.4 0.6 9.1 6.5 312 11 297 165 -0.8 0 -0.5 -0.8 01/14/2007 06:40:00 7.6 0.9 12.6 5.3 8 0.6 9.1 5.3 8.7 0.5 9.5 6.8 326 13 341 165 -0.9 0 -0.5 -1 01/14/2007 06:50:00 8.4 1.7 14.1 6.8 8.2 0.4 8.8 6.1 9.7 2 17.9 7.6 326 13 346 165 -1 0 -0.8 -1.2 01/14/2007 07:00:00 8.7 1.7 13.3 6.8 8.4 0.3 9.1 7.6 9.7 2.1 16.8 8 316 9 324 165 -1.1 0 -0.8 -1.2 01/14/2007 07:10:00 9.9 2 14.5 7.2 8.6 0.6 12.2 7.6 10.1 2.3 17.6 8.4 313 8 311 165 -1.2 0 -1 -1.4 01/14/2007 07:20:00 9.9 2 14.5 7.2 9 0.8 14.1 8 10.8 2.6 18.3 8.4 320 8 318 165 -1.3 0 -1.2 -1.4 01/14/2007 07:30:00 9.4 1.7 13.7 6.8 8.9 0.3 9.5 8 9.2 1 14.9 7.6 321 10 307 165 -1.4 0 -1.2 -1.4 01/14/2007 07:40:00 10 1.8 14.5 7.2 9.1 0.9 15.3 6.5 9.3 1.2 17.6 8.4 323 10 296 165 -1.6 0 -1.4 -1.7 01/14/2007 07:50:00 11.4 1.9 16.1 7.2 9.8 2.1 19.5 7.6 11 3.1 18.7 8.4 322 13 282 165 -1.6 0 -1.4 -1.9 01/14/2007 08:00:00 11.1 1.8 14.5 7.6 9.2 0.2 9.9 8 11.9 2.9 17.6 8 319 8 312 165 -1.5 0.1 -1.2 -1.9 01/14/2007 08:10:00 11.1 1.5 13.7 7.6 9.2 0.2 9.5 8.4 10.6 2.3 16.4 8.4 316 8 313 165 -1.4 0 -1.2 -1.7 01/14/2007 08:20:00 11.1 1.7 15.6 7.6 9.6 1.3 16.4 8.8 9.2 0.2 9.9 8.8 313 6 314 165 -1.5 0 -1.4 -1.7 01/14/2007 08:30:00 11.2 1.7 14.9 7.6 9.2 0.2 9.9 8.8 9.4 0.9 14.5 8.8 313 6 307 165 -1.5 0 -1.4 -1.7 01/14/2007 08:40:00 10.2 1.8 14.5 7.6 9.2 0.2 9.9 8.4 9.2 0.2 9.5 8.4 315 8 299 165 -1.4 0 -1.2 -1.4 01/14/2007 08:50:00 9.6 1.9 14.1 5.7 9.1 0.5 9.9 6.5 9.2 0.3 9.9 8 317 11 332 165 -1.4 0 -1.2 -1.4 01/14/2007 09:00:00 12.9 2.7 18.3 7.6 12 3.2 20.6 8.8 12.4 3.3 19.5 8 316 11 322 165 -1.2 0 -1 -1.4 01/14/2007 09:10:00 17.6 1.2 21 14.1 10.5 2.3 20.2 8.8 10.4 1.8 17.6 8.8 315 9 308 165 -1.3 0.1 -1 -1.4 01/14/2007 09:20:00 17.3 1.2 19.9 12.6 9.5 0.2 9.9 8.8 9.5 0.2 9.9 8.8 316 6 325 165 -1.4 0 -1.2 -1.7 01/14/2007 09:30:00 18.9 0.8 20.6 15.6 9.7 0.2 9.9 9.5 9.7 0.2 9.9 9.5 317 6 319 165 -1.4 0 -1.2 -1.4 01/14/2007 09:40:00 19.5 0.6 20.6 17.2 15.4 1.6 17.9 9.5 16.1 1.5 18.3 9.5 318 5 311 165 -1.4 0 -1.2 -1.4 01/14/2007 09:50:00 19.6 0.6 20.6 17.2 15.8 0.9 17.9 12.6 16.5 0.8 18.3 13.7 316 4 315 165 -1.4 0 -1.2 -1.4 01/14/2007 10:00:00 19.1 0.9 20.6 16.1 14.6 1.9 17.9 9.1 15.7 1.1 19.1 12.6 318 6 319 165 -1.3 0 -1 -1.4 01/14/2007 10:10:00 18.6 1.1 20.6 15.3 12 2.9 19.1 9.1 15.4 1.9 20.2 9.1 320 7 324 165 -0.8 0.1 -0.5 -1.2 01/14/2007 10:20:00 17.2 1.1 19.9 13.7 9.9 0.1 10.3 9.5 9.9 0.1 10.3 9.5 321 7 311 165 -0.9 0 -0.8 -1.2 01/14/2007 10:30:00 16.4 1.5 19.5 9.5 9.8 0.6 15.6 9.1 11.1 2.3 17.6 9.1 326 8 315 165 -0.8 0.1 -0.5 -1.2 01/14/2007 10:40:00 16 1.7 19.9 9.9 10.1 1.1 17.2 9.1 10.6 1.9 17.9 9.1 322 8 319 165 -0.8 0 -0.5 -1 01/14/2007 10:50:00 14.9 1.8 18.3 9.1 9.8 0.3 10.3 8.8 9.8 0.5 15.3 8.4 320 7 317 165 -1.1 0 -0.8 -1.4 01/14/2007 11:00:00 13.8 2.3 19.5 9.1 10.3 1.7 17.2 8.8 10.4 2 18.3 8 327 8 332 165 -1 0.1 -0.8 -1.4 01/14/2007 11:10:00 16.4 1.7 21 12.2 12.2 2.8 19.5 9.1 13.4 2.9 19.5 9.5 324 9 313 165 -0.6 0.1 -0.3 -1 01/14/2007 11:20:00 15.9 1.7 20.2 9.5 11.7 2.3 18.3 9.1 11.8 2.5 17.6 9.1 319 8 309 165 -0.6 0 -0.3 -0.8 01/14/2007 11:30:00 15.2 1.7 19.5 9.1 10.5 1.5 17.9 9.1 10.9 1.9 19.1 9.1 318 7 315 165 -0.8 0.1 -0.5 -1 01/14/2007 11:40:00 13.4 1.9 18.3 9.1 10 0.7 16.1 9.1 10.5 1.4 15.6 8.4 315 7 321 165 -0.9 0 -0.5 -1.2 01/14/2007 11:50:00 13.8 1.5 18.3 9.9 10.1 0.3 10.3 9.1 10.2 1 17.9 8.8 312 7 319 165 -0.8 0.1 -0.5 -1.2 01/14/2007 12:00:00 15 1.9 19.1 9.1 12.8 2.5 17.9 9.1 12.3 2.4 18.3 9.1 316 9 305 165 -0.2 0.1 0.2 -0.8 01/14/2007 12:10:00 13.9 1.5 17.9 9.1 10.9 1.5 17.2 8.8 10.5 1.1 16.1 8.8 316 8 325 165 -0.1 0.1 0.2 -0.5 01/14/2007 12:20:00 14 2.1 20.6 9.1 11.8 2.3 19.9 8.8 11.3 2.2 18.3 8.8 318 9 295 165 0.2 0.1 0.7 -0.1 01/14/2007 12:30:00 13.7 1.5 16.8 9.1 11.3 1.7 15.6 9.1 10.7 1.5 15.6 7.2 312 8 312 165 0.1 0 0.4 -0.1 01/14/2007 12:40:00 13.7 2.3 17.6 9.1 12.2 2.3 17.2 9.1 11.2 2.1 16.8 7.6 311 7 307 165 -0.1 0.2 0.2 -0.5 01/14/2007 12:50:00 15.3 1.7 19.5 9.1 14 2 18.7 9.1 12.5 2.5 19.1 8.8 311 7 307 165 -0.6 0 -0.3 -0.8 01/14/2007 13:00:00 15.3 1.5 19.5 10.3 13.9 1.8 18.3 10.3 12.8 2.4 18.7 9.5 311 7 310 165 -0.5 0.1 -0.1 -0.8 01/14/2007 13:10:00 15.3 1.7 20.6 10.3 13.8 2.1 19.1 10.3 13.1 2.4 20.6 8 313 8 304 165 -0.2 0.1 0.2 -0.5 01/14/2007 13:20:00 15.8 1.9 20.2 9.9 14.7 2.1 19.1 9.1 14 2.2 20.2 9.1 310 8 305 165 0 0 0.2 -0.3 01/14/2007 13:30:00 15.3 1.6 19.5 10.3 14.5 1.7 18.3 10.3 13.5 1.7 18.7 9.5 307 8 306 165 -0.2 0 -0.1 -0.3 01/14/2007 13:40:00 15.8 2 21 10.3 15 2.3 19.9 10.3 13.8 1.7 19.5 9.5 308 9 300 165 0.1 0.1 0.7 -0.3 01/14/2007 13:50:00 15.9 1.9 21 10.7 15.6 1.9 21 10.7 14.2 1.9 18.7 9.5 309 7 306 165 0.4 0 0.9 0.2 01/14/2007 14:00:00 15.9 1.6 19.9 10.3 15.6 1.6 20.2 10.3 13.8 1.8 19.5 8.4 307 7 304 165 0.4 0 0.7 0.2 01/14/2007 14:10:00 15.9 1.5 19.9 10.7 15.8 1.6 19.9 10.3 14.4 1.7 18.3 10.3 309 7 290 165 0.4 0.1 0.7 0.2 01/14/2007 14:20:00 16.7 1.5 19.9 12.2 16.4 1.5 19.9 10.7 15 1.3 18.3 10.7 308 6 296 165 0.3 0 0.7 0.2 01/14/2007 14:30:00 16.4 1.5 20.2 11.8 15.9 1.5 19.9 10.7 15 1.6 20.2 9.9 310 6 313 165 0.2 0 0.7 0.2 01/14/2007 14:40:00 15.1 1.3 19.1 11.1 14.7 1.3 18.7 10.7 14 1.3 16.8 9.9 312 6 311 165 0.2 0 0.2 -0.1 01/14/2007 14:50:00 14.4 1.1 18.3 11.5 14.1 1.2 17.6 10.7 13.6 1.3 16.8 9.5 313 6 315 165 0.1 0 0.2 -0.1 01/14/2007 15:00:00 15.3 1.4 21 12.2 14.9 1.4 19.9 11.8 14.7 1.5 19.5 11.1 317 6 321 165 0.1 0 0.2 -0.1 01/14/2007 15:10:00 16.9 1 19.9 14.1 16.5 1 19.1 13.3 16.6 1.1 19.1 12.6 318 5 317 165 0.2 0 0.2 -0.1 01/14/2007 15:20:00 16.8 1 19.5 13.7 16.4 0.9 19.1 13.7 16.5 1 19.5 14.1 316 4 314 165 -0.1 0 0.2 -0.3 01/14/2007 15:30:00 16.6 1.3 20.2 13 16.1 1.2 19.5 12.6 16.2 1.3 19.5 13 316 4 316 165 -0.3 0 -0.1 -0.5 01/14/2007 15:40:00 15.9 1.3 18.7 12.2 15.5 1.2 18.3 11.8 15.4 1.3 18.3 11.8 316 6 329 165 -0.3 0 -0.1 -0.5 01/14/2007 15:50:00 15.8 1.3 19.5 12.2 15.4 1.2 19.1 12.6 15.2 1.3 19.5 11.8 314 6 309 165 -0.5 0 -0.3 -0.8 01/14/2007 16:00:00 15.8 1.2 18.7 12.6 15.4 1.1 17.9 12.6 15.2 1.3 18.3 11.8 315 6 307 165 -0.5 0 -0.3 -0.8 01/14/2007 16:10:00 16.2 1.2 19.9 13.3 15.8 1.2 19.5 13 15 1.2 18.3 11.8 311 5 308 165 -0.9 0.1 -0.5 -1 01/14/2007 16:20:00 17.5 1 19.5 14.9 17 1 18.7 14.1 15.9 1.2 19.5 12.2 310 5 304 165 -0.9 0 -0.8 -1 01/14/2007 16:30:00 17.1 1.2 19.9 14.5 16.7 1.1 19.5 14.1 15 1.3 18.3 10.3 308 5 310 165 -1 0 -0.8 -1.2 01/14/2007 16:40:00 18.3 1 21 14.9 17.9 1 20.2 14.9 16.2 1.3 19.5 12.2 306 4 298 165 -0.9 0.1 -0.5 -1.2 01/14/2007 16:50:00 18.6 1.2 21 15.3 18.2 1.1 20.2 15.3 16.6 1.3 20.2 12.6 307 5 304 165 -0.8 0 -0.5 -1 01/14/2007 17:00:00 20.3 1.3 23.3 15.6 19.9 1.3 22.6 16.1 18 1.5 21.8 13.7 307 4 307 165 -0.4 0.2 -0.1 -0.8 01/14/2007 17:10:00 20.5 1.2 23.3 16.8 20.2 1.2 22.9 16.4 19.1 1.5 22.9 14.1 309 5 300 165 -0.1 0 0.2 -0.3 01/14/2007 17:20:00 19.8 1.2 22.9 15.6 19.4 1.2 22.6 16.1 18.5 1.7 23.7 12.2 307 5 307 165 -0.3 0 -0.1 -0.5 01/14/2007 17:30:00 19 1.3 21.8 14.9 18.7 1.2 21.8 14.5 17.3 1.7 21.8 12.2 307 5 307 165 -0.5 0 -0.3 -0.8 01/14/2007 17:40:00 18.6 1.3 21.4 14.1 18.4 1.2 21.4 14.1 16.4 1.6 20.6 11.5 305 6 302 165 -0.6 0 -0.5 -0.8 01/14/2007 17:50:00 18.7 1.2 21.4 15.3 18.4 1.2 21.4 14.9 15.8 1.8 21 11.1 305 6 301 165 -0.5 0 -0.3 -0.8 01/14/2007 18:00:00 18.5 1.5 22.9 14.9 18.2 1.5 22.6 14.9 16.8 2.2 23.3 11.8 306 7 311 165 -0.5 0.1 -0.3 -0.8 01/14/2007 18:10:00 19.6 1.6 22.9 15.3 19.4 1.5 22.9 15.3 18.7 2.3 22.9 12.6 308 7 309 165 -0.3 0 -0.1 -0.5 01/14/2007 18:20:00 20.1 1.2 22.9 17.2 19.8 1.2 22.6 17.2 18.9 2.2 24 11.5 308 5 316 165 -0.2 0.1 -0.1 -0.3 01/14/2007 18:30:00 18.7 1.3 21.4 15.6 18.4 1.2 21.4 15.3 16.9 1.9 21.8 11.8 306 7 311 165 -0.5 0 -0.3 -0.8 01/14/2007 18:40:00 18.9 1.3 22.1 15.3 18.7 1.3 22.6 15.3 16.7 2.1 23.3 12.2 305 7 298 165 -0.6 0 -0.5 -0.8 01/14/2007 18:50:00 21.2 1.7 24 16.1 20.9 1.7 24.4 16.1 20.6 2 24.8 14.5 310 7 307 165 -0.5 0 -0.3 -0.8 01/14/2007 19:00:00 23.4 1.6 26.8 19.5 23.1 1.5 26 19.5 22.1 1.8 26 16.8 308 5 307 165 -0.5 0.1 -0.1 -0.8 01/14/2007 19:10:00 22.7 1.6 26 18.7 22.4 1.5 25.6 18.7 20.2 1.8 25.6 14.1 305 5 310 165 -0.5 0.2 -0.1 -1 01/14/2007 19:20:00 22.1 1.3 25.2 18.7 21.8 1.2 24.8 18.3 20.7 1.6 24.4 16.4 308 5 310 165 -0.9 0 -0.8 -1.2 01/14/2007 19:30:00 20.4 1.3 22.9 14.5 20.1 1.3 22.6 14.9 19.1 1.9 23.3 13.7 308 5 309 165 -0.8 0.1 -0.5 -1 01/14/2007 19:40:00 19.7 1.5 23.7 15.3 19.5 1.5 23.7 15.6 17.8 2.2 23.3 11.5 306 6 309 165 -1 0 -0.8 -1.2 01/14/2007 19:50:00 21.2 1.7 26.3 17.6 21 1.7 25.6 16.8 19.2 2.7 26 12.2 304 6 302 165 -1 0 -0.8 -1.2 01/14/2007 20:00:00 21.2 1.4 24.8 17.2 21 1.4 24.8 17.2 17.1 1.9 21.8 12.6 300 7 282 165 -1.3 0.1 -0.8 -1.4 01/14/2007 20:10:00 21.5 1.3 24.4 17.9 21.3 1.3 24.4 17.9 17.6 1.8 22.6 13.3 302 6 307 165 -1.4 0 -1.2 -1.4 01/14/2007 20:20:00 22.2 1.5 26 17.9 22 1.5 26.3 17.9 20.1 2.2 26.8 14.5 305 7 307 165 -1.2 0.1 -0.8 -1.4 01/14/2007 20:30:00 21.4 1.4 24.4 17.9 21.2 1.4 24.8 17.9 20.6 2 26 15.3 308 6 307 165 -0.9 0 -0.8 -1.2 01/14/2007 20:40:00 21 1.7 26 16.4 20.8 1.7 25.2 16.4 18.6 1.9 24 13 303 8 292 165 -1.2 0 -0.8 -1.4 01/14/2007 20:50:00 21.9 1.6 26.8 18.3 21.7 1.6 26.3 17.9 19.6 2.3 26 14.5 303 7 307 165 -1.2 0 -1 -1.4 01/14/2007 21:00:00 22.8 1.7 27.1 17.9 22.6 1.7 27.1 17.6 20.4 2.3 26.3 14.9 303 7 305 165 -1.2 0 -1 -1.4 01/14/2007 21:10:00 22.6 1.7 26.8 17.9 22.4 1.7 26.3 17.9 19.3 2.5 25.6 12.6 301 7 302 165 -1.2 0 -1 -1.4 01/14/2007 21:20:00 24 1.5 27.1 19.9 23.7 1.4 26.8 19.5 19.2 1.7 25.6 13.7 299 6 300 165 -1.2 0 -1 -1.4 01/14/2007 21:30:00 23.6 1.6 26.8 18.3 23.3 1.5 26.3 17.9 19.3 1.8 24.4 12.6 300 7 307 165 -1.3 0 -1.2 -1.4 01/14/2007 21:40:00 23 1.7 26 19.1 22.7 1.6 25.6 19.1 19.8 1.9 24.4 15.3 304 7 306 165 -1.1 0.2 -0.8 -1.4 01/14/2007 21:50:00 21.8 1.7 25.6 17.6 21.6 1.6 25.6 17.2 19.8 1.5 24 15.3 305 7 310 165 -0.8 0.1 -0.5 -1 01/14/2007 22:00:00 20.6 1.3 24.4 17.6 20.4 1.3 24.8 17.2 19.6 1.7 23.3 13.7 310 7 309 165 -0.9 0.2 -0.5 -1.2 01/14/2007 22:10:00 18.8 1.7 23.3 14.9 18.7 1.6 23.3 14.5 18.4 1.9 23.7 13.3 314 8 317 165 -0.6 0.2 -0.1 -1.2 01/14/2007 22:20:00 20.1 2 25.2 15.6 20 2 24 15.3 19 1.8 23.7 14.5 309 9 297 165 -0.9 0 -0.5 -1.2 01/14/2007 22:30:00 20.9 1.5 24.8 17.2 20.7 1.5 24.8 17.2 19 2 24.8 14.1 307 5 310 165 -1.4 0.1 -1 -1.7 01/14/2007 22:40:00 20.3 1.5 23.3 15.3 20.1 1.5 22.9 15.6 18.1 2 23.7 13 306 6 308 165 -1.6 0 -1.4 -1.9 01/14/2007 22:50:00 18.8 1.6 22.9 14.1 18.6 1.6 22.6 14.1 17.2 2 21.8 11.5 306 7 304 165 -2 0.1 -1.7 -2.1 01/14/2007 23:00:00 17.3 1.6 22.1 13 17.1 1.6 22.1 13 14.9 2.1 20.6 9.5 303 9 310 165 -2.1 0 -1.9 -2.4 01/14/2007 23:10:00 17 1.9 22.6 12.6 16.8 1.9 21.8 12.6 14.4 2.3 21.8 9.9 300 10 303 165 -2.2 0 -1.9 -2.6 01/14/2007 23:20:00 16.8 1.5 20.6 13.3 16.7 1.5 20.6 12.6 13.5 1.8 20.2 9.1 295 9 291 165 -2.2 0 -1.9 -2.6 01/14/2007 23:30:00 16.7 1.6 21 12.6 16.5 1.6 20.6 12.2 13.4 1.9 19.9 8.8 295 10 266 165 -2.1 0 -1.9 -2.4 01/14/2007 23:40:00 15.7 1.6 19.1 11.5 15.6 1.6 19.1 11.1 12.2 1.7 18.3 8 295 10 301 165 -2.2 0 -1.9 -2.6 01/14/2007 23:50:00 17.5 1.8 21 12.6 17.4 1.8 21.4 13 13.6 1.7 19.9 9.1 296 9 290 165 -2.3 0 -2.1 -2.6 01/15/2007 00:00:00 18 1.9 22.1 12.6 17.8 1.9 22.1 13 14.3 1.9 19.9 9.9 296 9 301 165 -2.4 0 -2.1 -2.6 01/15/2007 00:10:00 18.4 1.7 22.6 14.1 18.2 1.7 22.1 14.1 14.9 1.8 21 11.1 296 10 299 165 -2.5 0 -2.1 -2.6 01/15/2007 00:20:00 19.9 2.1 24.4 14.5 19.7 2 24 14.9 17.8 2.6 24 13 303 11 295 165 -2.5 0 -2.1 -2.6 01/15/2007 00:30:00 19.4 1.8 23.7 14.9 19.2 1.8 24 14.5 18.2 2.6 25.2 12.2 305 10 319 165 -2.3 0 -2.1 -2.6 01/15/2007 00:40:00 18 1.7 22.9 13.7 17.8 1.7 22.9 13.7 16.6 2.1 22.6 11.1 305 11 301 165 -2.4 0 -2.1 -2.6 01/15/2007 00:50:00 15.9 2.1 21 11.5 15.7 2.1 21 11.5 14.2 2.4 21 9.1 303 11 305 165 -2.6 0 -2.4 -2.8 01/15/2007 01:00:00 17.4 2.3 25.2 12.2 17.3 2.4 24.4 11.5 16.1 2.6 24 9.5 305 9 317 165 -2.6 0.1 -2.6 -2.8 01/15/2007 01:10:00 18.2 1.8 24 13.3 18.1 1.8 24.4 13.3 16.9 2.2 22.1 11.5 307 9 307 165 -2.5 0 -2.4 -2.8 01/15/2007 01:20:00 18.7 2.1 23.3 13.7 18.6 2.1 23.7 13.3 17.9 2.6 24.4 9.5 310 9 312 165 -2.5 0 -2.4 -2.8 01/15/2007 01:30:00 15 2.1 21 8.8 15.1 2.2 20.6 8.8 13.3 2.7 20.2 5.7 308 12 313 165 -2.8 0 -2.6 -3 01/15/2007 01:40:00 10.3 2.5 17.2 3.4 10.3 2.5 16.8 3.4 8 2.7 16.4 1.5 303 19 328 165 -3 0.1 -2.8 -3.3 01/15/2007 01:50:00 13.4 3.1 19.1 3.8 13.4 3.2 19.1 3.8 11.5 3.2 17.6 2.3 301 12 302 165 -3 0 -2.6 -3.3 01/15/2007 02:00:00 15.3 1.7 19.5 9.9 15.4 1.7 20.2 9.9 13.9 2 19.9 9.1 305 9 301 165 -2.7 0.1 -2.4 -3 01/15/2007 02:10:00 17.8 1.6 21.8 12.6 17.7 1.6 21.8 12.6 17 2.3 21.8 11.1 312 8 316 165 -2.4 0 -2.1 -2.6 01/15/2007 02:20:00 13.8 1.9 19.1 9.5 13.8 1.9 19.1 9.5 12.8 2.2 19.9 8 311 9 310 165 -2.5 0 -2.1 -2.8 01/15/2007 02:30:00 11.6 1.9 16.1 5.7 11.6 1.9 16.4 6.1 10.1 2.4 16.1 2.6 303 14 308 165 -2.8 0 -2.6 -3 01/15/2007 02:40:00 11.7 1.9 18.7 6.8 11.8 1.9 18.7 7.2 9.8 2.3 18.7 3.4 304 13 289 165 -2.9 0.1 -2.8 -3 01/15/2007 02:50:00 11.7 1.9 16.8 7.2 11.7 1.9 17.6 7.2 10.3 2.3 16.4 5.3 307 13 311 165 -2.9 0 -2.8 -3 01/15/2007 03:00:00 11.4 1.6 16.1 7.2 11.3 1.7 16.4 6.5 10.2 1.8 15.6 5.3 311 12 295 165 -3 0.1 -2.6 -3.3 01/15/2007 03:10:00 10.6 1.7 15.3 4.9 10.6 1.7 14.9 5.7 9.1 1.8 14.1 4.2 307 13 297 165 -3.1 0 -2.8 -3.3 01/15/2007 03:20:00 10.2 2.1 15.3 3.8 10.2 2.1 15.3 3.4 8.4 2.4 14.9 2.3 313 16 290 165 -3 0 -2.8 -3.3 01/15/2007 03:30:00 9.9 2.4 16.8 4.2 10 2.5 17.2 3 7.5 2.6 16.4 1.9 309 17 321 165 -3 0 -2.8 -3.3 01/15/2007 03:40:00 13.2 2.7 19.5 5.3 13.2 2.8 19.9 5.7 11.3 3.1 17.6 3.8 313 11 313 165 -2.9 0 -2.8 -3.3 01/15/2007 03:50:00 14.8 1.8 18.7 9.9 14.8 1.8 19.1 9.9 13.8 2 19.1 8 314 10 328 165 -2.8 0 -2.6 -2.8 01/15/2007 04:00:00 14.4 1.7 19.1 10.3 14.3 1.7 18.7 9.1 13.8 1.7 18.3 9.5 320 9 312 165 -3 0 -2.8 -3 01/15/2007 04:10:00 14.8 2 19.9 9.9 14.7 1.9 19.9 9.9 14.1 2.1 19.5 9.1 317 8 312 165 -2.8 0 -2.6 -3 01/15/2007 04:20:00 15.1 1.8 20.6 10.7 14.9 1.7 20.2 10.3 14.7 1.7 19.1 10.3 317 8 307 165 -2.8 0 -2.6 -3 01/15/2007 04:30:00 15.5 1.8 20.6 10.7 15.3 1.8 20.6 10.7 14.3 2.1 19.9 8.8 311 9 310 165 -2.5 0 -2.4 -2.8 01/15/2007 04:40:00 9.5 2 14.5 4.9 9.2 2.2 14.1 4.6 8.4 2.1 14.5 4.2 322 23 330 165 -2.8 0.2 -2.4 -3 01/15/2007 04:50:00 11.3 2.3 18.3 3.8 11.2 2.3 17.9 4.2 10.2 2.2 16.4 3.8 311 13 301 165 -2.7 0 -2.6 -2.8 01/15/2007 05:00:00 13.3 2.1 17.9 8.4 13.3 2.1 17.2 8.4 11.8 2.2 16.4 6.5 310 11 305 165 -2.6 0 -2.6 -2.8 01/15/2007 05:10:00 14.2 2.3 20.2 8.8 14.1 2.3 19.9 8.8 12.9 2.4 18.3 6.5 310 9 286 165 -2.6 0 -2.6 -2.8 01/15/2007 05:20:00 17.1 1.3 20.6 12.6 16.8 1.2 21 12.2 16.6 1.3 20.2 11.5 314 6 301 165 -2.6 0 -2.6 -2.8 01/15/2007 05:30:00 18.1 1.1 21 14.1 17.8 1.1 21 13.7 17.6 1.5 20.6 10.7 314 7 308 165 -2.6 0 -2.6 -2.8 01/15/2007 05:40:00 18 1 21.8 15.3 17.7 1.1 21.4 14.5 18.1 1.2 21.8 14.5 317 4 323 165 -2.8 0 -2.6 -3 01/15/2007 05:50:00 16.7 1.3 20.2 12.6 16.4 1.2 19.9 13 16.5 1.5 20.2 12.6 319 6 320 165 -3 0.1 -2.6 -3.3 01/15/2007 06:00:00 17.3 1.2 21 12.6 17 1.2 20.6 11.8 17 1.4 20.6 11.8 315 6 313 165 -2.9 0 -2.6 -3.3 01/15/2007 06:10:00 16.1 1.2 19.5 13 15.8 1.2 19.1 12.6 15.8 1.3 19.1 12.6 313 7 310 165 -2.8 0 -2.6 -3 01/15/2007 06:20:00 17.1 1.3 20.6 12.6 16.8 1.3 19.9 12.6 16.3 1.5 19.5 12.6 312 6 307 165 -3 0 -2.8 -3.3 01/15/2007 06:30:00 18.8 1.5 24.4 14.5 18.4 1.5 24 14.5 18.6 1.7 24 13.7 318 6 313 165 -2.8 0 -2.6 -3 01/15/2007 06:40:00 18.7 1.5 23.3 13.7 18.4 1.5 22.6 14.1 18.5 1.7 23.3 12.6 320 8 316 165 -2.8 0 -2.6 -2.8 01/15/2007 06:50:00 19.6 1.5 24.4 15.3 19.3 1.5 24 15.6 19.6 1.7 24.4 14.5 317 5 315 165 -2.8 0 -2.6 -3 01/15/2007 07:00:00 19.8 1.7 23.3 14.5 19.5 1.7 22.9 14.5 19.8 1.8 23.7 13.3 318 6 314 165 -2.8 0 -2.6 -3 01/15/2007 07:10:00 18.8 1.4 22.1 14.9 18.5 1.4 22.6 14.5 17.8 1.5 21.4 12.6 310 7 309 165 -2.9 0.1 -2.6 -3 01/15/2007 07:20:00 18.1 1.5 22.6 14.1 17.9 1.4 22.6 14.9 17.3 1.6 22.9 13 311 6 310 165 -2.9 0 -2.8 -3 01/15/2007 07:30:00 18.3 1.7 22.6 14.1 18.1 1.6 22.1 14.1 17.5 1.8 21.8 13 311 7 311 165 -2.9 0 -2.8 -3 01/15/2007 07:40:00 18.3 1.8 21.8 12.6 18 1.7 21.8 12.2 18 2 22.6 12.2 314 9 301 165 -2.9 0 -2.8 -3 01/15/2007 07:50:00 16.1 1.6 19.5 12.2 15.9 1.5 19.1 12.2 15.7 1.5 20.6 11.8 315 9 321 165 -3 0.1 -2.8 -3.3 01/15/2007 08:00:00 13.4 2.3 19.1 8.4 13.2 2.2 18.7 8.8 13 2.5 19.1 7.6 316 12 316 165 -3.2 0 -3 -3.5 01/15/2007 08:10:00 11.1 1.4 15.3 7.6 11 1.4 15.3 7.6 9.4 1.3 12.2 6.5 302 10 310 165 -3.4 0 -3 -3.5 01/15/2007 08:20:00 9.2 1.5 12.6 5.7 9.1 1.5 13 5.7 8.3 1.5 13 4.6 310 13 304 165 -3.2 0 -3 -3.5 01/15/2007 08:30:00 9.8 1.2 13 6.8 9.7 1.2 12.6 6.5 8.5 1.4 11.8 5.3 305 9 302 165 -3.1 0.1 -2.8 -3.5 01/15/2007 08:40:00 8.9 1 11.5 5.7 8.8 1 11.5 6.1 7.7 1.3 10.7 4.6 305 8 307 165 -3.3 0 -3 -3.5 01/15/2007 08:50:00 7.5 1.3 11.1 4.6 7.5 1.3 11.1 4.6 6.1 1.2 9.5 3.8 302 9 308 165 -3.3 0 -3 -3.5 01/15/2007 09:00:00 6.3 1 9.5 4.2 6.3 1 9.1 4.2 5.4 1 9.1 3.4 305 10 292 165 -3.4 0 -3.3 -3.5 01/15/2007 09:10:00 7.7 1.6 12.2 4.6 7.6 1.5 11.8 4.6 6.8 1.7 11.8 3 306 11 310 165 -3.3 0 -3 -3.5 01/15/2007 09:20:00 8.2 1.1 11.1 5.3 8.1 1.1 11.1 4.9 8 1 11.5 5.3 316 10 293 165 -3.2 0 -3 -3.3 01/15/2007 09:30:00 9.5 1 12.6 6.8 9.4 1 12.2 7.2 8.8 1.1 11.5 5.7 312 8 307 165 -3 0 -2.8 -3.3 01/15/2007 09:40:00 9.8 1.4 13.7 6.8 9.7 1.3 13.3 6.8 8.7 1.3 11.8 5.7 308 9 308 165 -2.9 0 -2.6 -3.3 01/15/2007 09:50:00 11.4 1.3 14.9 8 11.2 1.2 14.1 8 10.5 1.5 14.9 6.8 311 6 310 165 -2.7 0 -2.6 -2.8 01/15/2007 10:00:00 10.2 1.2 13 6.5 10 1.1 12.6 6.8 9.6 1.3 13 6.5 313 8 305 165 -2.7 0 -2.6 -3 01/15/2007 10:10:00 9.9 1.2 12.6 7.2 9.7 1.2 12.6 7.2 9.3 1.4 12.2 5.3 312 8 305 165 -2.8 0 -2.6 -2.8 01/15/2007 10:20:00 9.8 0.8 12.6 8 9.6 0.8 11.8 8 8.8 1 12.2 5.7 309 8 311 165 -2.8 0 -2.6 -3 01/15/2007 10:30:00 9.8 1 12.2 6.5 9.7 1 12.2 6.1 8.7 1.1 12.2 6.1 308 6 310 165 -2.8 0 -2.6 -2.8 01/15/2007 10:40:00 9.5 1.1 12.2 5.7 9.4 1.1 12.2 5.7 7.8 1.1 11.5 4.6 301 9 302 165 -2.7 0 -2.6 -2.8 01/15/2007 10:50:00 10.4 1.1 14.1 7.6 10.3 1.1 14.1 7.6 8.4 1.4 12.2 5.3 299 10 300 165 -2.6 0 -2.6 -2.8 01/15/2007 11:00:00 10.6 1.3 14.5 7.2 10.4 1.2 14.1 7.2 9.7 1.6 14.9 6.1 309 8 302 165 -2.6 0 -2.6 -2.8 01/15/2007 11:10:00 9.9 1.5 13.7 5.7 9.8 1.5 13.3 5.3 9 1.7 13.7 4.2 307 11 313 165 -2.6 0.1 -2.6 -2.8 01/15/2007 11:20:00 10.6 1.4 14.5 6.5 10.5 1.3 14.1 6.5 9.3 1.5 13.7 5.3 302 11 295 165 -2.5 0 -2.4 -2.8 01/15/2007 11:30:00 11.6 1.9 16.4 7.2 11.5 1.9 16.1 7.2 10.2 2.2 15.3 4.9 303 11 301 165 -2.5 0 -2.4 -2.8 01/15/2007 11:40:00 14.9 2 19.1 9.1 14.7 1.9 19.1 8.8 12 1.7 17.2 8 295 11 290 165 -2.5 0 -2.1 -2.6 01/15/2007 11:50:00 13 1.7 17.2 8.8 12.8 1.7 16.8 8.8 10.9 1.8 17.2 6.5 297 13 296 165 -2.5 0 -2.4 -2.8 01/15/2007 12:00:00 13.7 2 18.3 8.4 13.6 1.9 18.3 8 11.3 1.9 17.9 6.8 296 12 294 165 -2.5 0 -2.4 -2.8 01/15/2007 12:10:00 12.9 1.5 17.6 9.1 12.8 1.5 17.2 9.1 11.1 1.6 16.1 6.8 300 11 290 165 -2.5 0 -2.4 -2.6 01/15/2007 12:20:00 12 1.8 17.9 8 11.9 1.8 17.6 7.6 10.6 2.2 18.7 5.7 299 14 313 165 -2.5 0 -2.1 -2.6 01/15/2007 12:30:00 12.7 1.7 17.9 8.8 12.6 1.7 17.6 8.4 10.6 1.5 14.5 6.5 295 12 309 165 -2.5 0 -2.4 -2.6 01/15/2007 12:40:00 13 1.8 16.4 7.2 12.9 1.9 16.8 6.5 11.1 2.2 16.4 5.7 287 9 286 165 -2.5 0 -2.1 -2.6 01/15/2007 12:50:00 13.7 1.8 17.6 8.8 13.6 1.9 17.6 8.8 11.6 2.3 16.4 6.5 288 11 267 165 -2.2 0.1 -1.9 -2.6 01/15/2007 13:00:00 15.3 1.5 19.1 9.5 15.2 1.6 19.1 9.5 12.4 1.7 16.4 8 289 10 281 165 -2.1 0 -1.9 -2.6 01/15/2007 13:10:00 14.1 1.8 18.3 8.8 14 1.8 18.3 9.5 11.7 2.1 18.3 5.3 291 14 290 165 -2.1 0 -1.9 -2.4 01/15/2007 13:20:00 15 1.9 19.5 10.7 14.9 1.9 19.1 10.3 12.6 2.1 18.7 7.6 289 10 298 165 -2.1 0 -1.9 -2.4 01/15/2007 13:30:00 14 1.4 17.6 9.9 13.8 1.5 17.6 9.5 11.6 1.7 16.4 7.6 292 11 294 165 -2.1 0 -1.9 -2.4 01/15/2007 13:40:00 14.9 2 19.1 8.8 14.8 2.1 19.1 8.4 12.5 2.1 18.7 7.6 294 13 298 165 -2.2 0 -1.9 -2.4 01/15/2007 13:50:00 16 1.4 19.5 12.6 15.9 1.5 19.5 12.6 13.4 2.1 18.7 9.1 289 9 273 165 -2.3 0 -2.1 -2.4 01/15/2007 14:00:00 16.9 1.6 20.6 13.7 16.8 1.7 20.6 13.7 13.5 2.1 19.5 8.8 289 9 298 165 -2.3 0 -2.1 -2.6 01/15/2007 14:10:00 15 1.5 17.9 11.1 14.9 1.6 17.9 11.1 11.7 1.7 17.6 8 291 9 285 165 -2.4 0 -2.1 -2.6 01/15/2007 14:20:00 16.4 1.6 20.2 12.6 16.3 1.7 20.2 12.6 13.5 2.4 19.9 8.8 287 11 282 165 -2.2 0 -2.1 -2.6 01/15/2007 14:30:00 17.3 1.3 21 13.7 17.2 1.5 20.6 13.7 14.6 2.2 20.6 9.9 286 10 285 165 -2.2 0 -2.1 -2.4 01/15/2007 14:40:00 15.7 1.5 20.2 10.7 15.5 1.5 20.2 10.7 12.8 1.9 18.7 8.8 290 12 299 165 -2.2 0 -2.1 -2.6 01/15/2007 14:50:00 15.2 2 19.9 10.7 15.1 2.1 20.2 10.7 12.6 1.9 17.9 8.4 292 13 298 165 -2.3 0 -2.1 -2.6 01/15/2007 15:00:00 15.5 1.5 18.7 11.1 15.3 1.4 18.7 11.5 12.5 1.7 18.7 8 291 12 279 165 -2.5 0.1 -2.1 -2.8 01/15/2007 15:10:00 16.3 2.4 21.8 9.9 16.1 2.4 21.8 10.3 12.9 2.1 20.2 8 293 11 297 165 -2.7 0 -2.4 -2.8 01/15/2007 15:20:00 16.8 1.4 21.4 12.6 16.7 1.4 20.2 13.3 14.1 1.8 19.5 10.3 298 11 296 165 -2.8 0 -2.6 -3 01/15/2007 15:30:00 20.6 2 24.8 14.1 20.4 2.1 24.4 14.5 16.9 2.1 23.3 10.7 297 11 297 165 -2.8 0 -2.6 -3 01/15/2007 15:40:00 20.1 1.6 24 16.1 19.9 1.7 24 15.6 15.3 1.5 19.5 11.5 293 12 290 165 -2.6 0.1 -2.4 -2.8 01/15/2007 15:50:00 19.6 1.9 25.2 14.5 19.4 1.9 25.2 14.9 15.8 1.9 21.4 11.8 293 12 291 165 -2.5 0 -2.4 -2.6 01/15/2007 16:00:00 19 2 22.9 14.1 18.8 2 22.6 14.5 15.3 1.9 22.1 10.3 292 14 293 165 -2.5 0 -2.6 -2.8 01/15/2007 16:10:00 18.8 1.6 22.1 14.9 18.5 1.6 22.1 14.9 14.8 2 21 9.9 293 12 302 165 -2.7 0 -2.6 -2.8 01/15/2007 16:20:00 18.5 1.5 21.8 14.5 18.4 1.5 21.8 14.1 14.7 1.9 20.2 10.3 289 12 297 165 -2.8 0 -2.6 -2.8 01/15/2007 16:30:00 19.5 1.8 23.3 14.1 19.3 1.9 23.3 14.1 15.1 1.7 19.9 11.1 291 12 291 165 -2.9 0.1 -2.6 -3.3 01/15/2007 16:40:00 19 2.2 23.7 13.3 18.9 2.2 23.7 13.3 16.3 2.5 24.4 9.5 299 12 301 165 -3.1 0 -2.8 -3.3 01/15/2007 16:50:00 20.9 1.8 25.2 14.1 20.7 1.8 25.2 13.3 18.3 2.3 24 13 299 12 301 165 -3 0 -2.8 -3.3 01/15/2007 17:00:00 19.1 2 23.3 13.3 18.9 2 22.9 13.3 16.2 2.3 22.9 11.5 298 11 302 165 -3.1 0 -2.8 -3.3 01/15/2007 17:10:00 18.3 1.8 23.7 14.1 18.1 1.8 23.3 13.7 15.5 2.1 21 10.7 299 11 295 165 -3.3 0 -3 -3.5 01/15/2007 17:20:00 18.3 1.7 22.1 14.1 18.1 1.7 22.1 13.7 14.9 1.7 20.2 11.1 295 13 300 165 -3.3 0 -3 -3.5 01/15/2007 17:30:00 17.5 2.1 22.9 12.6 17.3 2.1 22.6 12.2 15.1 2.4 22.1 10.7 301 10 310 165 -3.3 0 -3 -3.5 01/15/2007 17:40:00 18.5 1.8 23.7 13.7 18.3 1.8 22.9 13.7 16.6 2.4 22.9 11.8 301 12 298 165 -3.3 0 -3 -3.5 01/15/2007 17:50:00 19.4 1.6 22.9 15.3 19.1 1.6 22.6 14.9 16.4 1.9 21.4 11.5 300 11 304 165 -3.4 0 -3.3 -3.5 01/15/2007 18:00:00 19.5 1.8 24 14.1 19.2 1.8 23.7 13.3 18.3 2 22.6 12.2 307 10 307 165 -3.4 0 -3.3 -3.5 01/15/2007 18:10:00 19.9 1.7 24 14.1 19.7 1.7 24 14.5 19.3 1.7 24 13 312 10 310 165 -3.4 0 -3.3 -3.5 01/15/2007 18:20:00 18.5 1.4 22.6 14.5 18.3 1.4 22.6 14.1 17.9 1.5 21.4 11.8 310 9 289 165 -3.4 0 -3 -3.5 01/15/2007 18:30:00 18 1.6 22.6 14.1 17.8 1.6 22.9 14.1 14.5 1.7 19.5 9.9 294 13 287 165 -3.4 0 -3.3 -3.5 01/15/2007 18:40:00 15.4 1.5 19.5 11.1 15.2 1.5 19.1 11.1 13.5 1.7 18.7 8.8 303 12 314 165 -3.4 0 -3.3 -3.5 01/15/2007 18:50:00 13.9 1.2 17.2 10.7 13.7 1.2 16.8 10.3 12.2 1.8 16.4 8.4 304 12 282 165 -3.4 0 -3.3 -3.5 01/15/2007 19:00:00 13.1 1.5 17.2 9.1 12.9 1.5 16.8 9.1 10.9 1.6 15.6 7.6 303 10 308 165 -3.4 0 -3.3 -3.5 01/15/2007 19:10:00 12.2 1.2 15.6 9.5 12 1.1 15.6 9.1 10.4 1.6 14.5 6.5 303 10 300 165 -3.4 0 -3.3 -3.5 01/15/2007 19:20:00 12.9 1.2 16.1 9.9 12.6 1.2 16.1 9.9 11.3 1.4 15.3 7.6 305 10 298 165 -3.4 0 -3.3 -3.5 01/15/2007 19:30:00 13.8 1.5 16.4 9.9 13.6 1.5 16.4 9.9 11.2 1.3 14.9 8 302 10 274 165 -3.4 0 -3.3 -3.5 01/15/2007 19:40:00 14 1.3 16.8 9.5 13.8 1.3 16.8 9.5 11.2 1.4 14.9 8 300 11 293 165 -3.4 0 -3.3 -3.5 01/15/2007 19:50:00 13.1 1.3 17.2 9.5 12.9 1.3 16.8 9.5 11.3 1.5 16.1 7.2 306 8 290 165 -3.5 0 -3.3 -3.5 01/15/2007 20:00:00 13.1 1.5 16.4 9.1 12.9 1.5 16.4 8.8 10.1 1.5 15.6 6.8 297 10 292 165 -3.5 0 -3.3 -3.7 01/15/2007 20:10:00 13.5 1.3 16.1 8.4 13.4 1.3 16.1 8.8 10.1 1.1 13.7 6.8 293 11 294 165 -3.5 0 -3.3 -3.7 01/15/2007 20:20:00 12.4 0.8 14.9 9.9 12.2 0.8 14.9 9.9 9.6 1.2 13.7 7.2 296 10 302 165 -3.7 0 -3.5 -3.9 01/15/2007 20:30:00 10.8 0.7 12.6 9.1 10.6 0.7 12.6 8.8 8.3 0.9 10.7 6.5 292 11 293 165 -3.6 0 -3.5 -3.9 01/15/2007 20:40:00 11.5 0.8 13.3 9.5 11.4 0.9 13.3 9.5 9.2 1.4 13.3 6.1 290 5 287 165 -3.4 0.1 -3 -3.5 01/15/2007 20:50:00 9.8 0.9 12.6 6.8 9.6 0.9 12.2 6.8 7.8 1 10.3 4.2 289 8 279 165 -3.4 0.1 -3 -3.5 01/15/2007 21:00:00 6.3 1.6 11.1 3 6.3 1.5 10.3 3 5 1.4 9.1 2.3 290 12 294 165 -3.7 0 -3.3 -3.9 01/15/2007 21:10:00 5.8 1 8 3 6.5 0.7 8.4 3.8 6.2 0.8 7.6 3.4 270 8 285 165 -3.6 0.1 -3.3 -3.9 01/15/2007 21:20:00 6.8 1.1 8.8 3.8 7.1 0.9 9.1 4.9 6.7 0.8 9.1 4.6 278 9 277 165 -3.3 0 -3 -3.5 01/15/2007 21:30:00 8.7 0.9 10.7 5.7 8.7 1 10.7 6.1 7.8 1 10.3 4.9 287 5 290 165 -3.5 0 -3.3 -3.5 01/15/2007 21:40:00 8 0.7 9.9 6.5 8 0.7 9.9 6.5 6.6 0.9 8.8 4.2 291 5 290 165 -3.6 0 -3.3 -3.7 01/15/2007 21:50:00 6.8 0.7 8.4 4.9 6.8 0.7 8.4 4.9 5.6 0.8 8 3.4 291 6 284 165 -3.6 0 -3.3 -3.7 01/15/2007 22:00:00 7.8 0.6 9.1 6.5 7.8 0.6 9.1 6.5 6.7 0.7 8.4 4.2 290 4 292 165 -3.5 0 -3.3 -3.7 01/15/2007 22:10:00 8.8 0.5 9.5 7.6 8.8 0.5 9.9 7.2 7.5 1 9.5 4.9 290 3 292 165 -3.4 0 -3.3 -3.5 01/15/2007 22:20:00 7.4 0.8 8.8 4.9 7.4 0.8 8.8 4.6 5.5 0.8 7.6 3.4 293 6 291 165 -3.4 0 -3.3 -3.5 01/15/2007 22:30:00 6.6 1 8.8 4.2 6.5 1 8.8 4.2 5.3 1 7.6 3.4 291 6 293 165 -3.3 0.1 -3 -3.5 01/15/2007 22:40:00 8.3 0.7 10.3 6.1 8.3 0.7 10.3 5.7 6.9 1 9.1 4.6 290 5 282 165 -3.2 0 -3 -3.3 01/15/2007 22:50:00 8.1 1.2 10.3 4.6 8.2 1.2 10.3 4.9 6.6 0.9 8.8 4.6 288 8 294 165 -3.2 0 -3 -3.5 01/15/2007 23:00:00 4.9 0.7 6.5 3 4.9 0.7 6.8 3 4.3 1 6.5 2.6 289 8 275 165 -3.3 0 -3 -3.5 01/15/2007 23:10:00 4.2 0.6 5.3 2.6 4.2 0.6 5.3 2.6 3.5 0.6 4.9 2.3 298 6 293 165 -3.3 0 -3 -3.5 01/15/2007 23:20:00 1.7 0.8 3.8 0.4 1.7 0.8 3.8 0.4 1.6 0.6 3 0.4 276 24 299 165 -3 0.2 -2.6 -3.3 01/15/2007 23:30:00 3 0.5 3.8 1.9 3 0.5 4.2 1.9 3 0.4 3.8 2.3 265 15 271 165 -2.5 0.1 -2.1 -2.8 01/15/2007 23:40:00 2.7 0.5 3.4 1.1 2.8 0.4 3.4 1.1 2.9 0.4 3.8 1.9 277 7 279 165 -2.6 0.1 -2.4 -2.8 01/15/2007 23:50:00 3.2 0.4 4.2 2.3 3.3 0.4 4.2 2.3 3.6 0.4 4.6 2.3 275 5 268 165 -2.9 0.2 -2.6 -3 01/16/2007 00:00:00 2.1 0.8 4.2 0.4 2.3 0.7 4.2 0.4 2.4 0.8 4.9 1.1 190 61 198 165 -2.9 0.2 -2.6 -3.5 01/16/2007 00:10:00 2.7 1.7 5.7 0.4 2.7 1.7 5.3 0.4 2.7 1.5 5.7 0.4 152 12 144 165 -3.3 0.1 -2.8 -3.5 01/16/2007 00:20:00 3.6 0.7 5.3 2.3 3.4 0.6 4.9 2.3 3.6 0.7 5.7 2.3 179 17 165 165 -2.8 0.3 -2.4 -3.3 01/16/2007 00:30:00 2.1 0.5 3.4 0.4 2.1 0.5 3.4 0.7 2.2 0.4 3.4 1.1 183 13 160 165 -2.5 0 -2.4 -2.8 01/16/2007 00:40:00 1.6 0.7 2.6 0.4 1.4 0.7 2.6 0.4 1.5 0.6 2.6 0.4 171 6 172 165 -2.5 0.1 -2.4 -2.8 01/16/2007 00:50:00 2.5 0.6 3.4 1.1 2.3 0.6 3 0.7 2.2 0.7 3.4 0.4 183 8 175 165 -2.4 0 -2.1 -2.6 01/16/2007 01:00:00 3.3 0.5 4.2 2.3 3.1 0.5 3.8 2.3 3 0.6 3.8 1.9 188 8 181 165 -2.1 0.1 -1.7 -2.4 01/16/2007 01:10:00 3.1 0.6 4.6 2.3 3 0.5 4.2 2.3 3 0.5 4.2 2.3 167 11 177 165 -2 0.1 -1.7 -2.4 01/16/2007 01:20:00 3.4 0.4 4.2 2.6 3.2 0.4 3.8 2.3 3.2 0.3 4.2 2.6 185 5 180 165 -1.7 0 -1.4 -1.9 01/16/2007 01:30:00 2.7 0.5 3.8 1.5 2.6 0.5 3.4 1.1 2.7 0.6 3.8 1.1 177 8 187 165 -1.8 0.1 -1.7 -2.1 01/16/2007 01:40:00 2.9 0.5 3.8 1.5 2.7 0.5 3.4 1.5 2.8 0.5 3.8 1.9 175 9 184 165 -2 0 -1.9 -2.1 01/16/2007 01:50:00 2.1 0.2 2.6 1.5 1.9 0.2 2.3 1.5 2.1 0.2 2.6 1.5 180 3 181 165 -1.8 0 -1.4 -2.1 01/16/2007 02:00:00 1.9 0.3 2.3 1.5 1.7 0.3 2.3 1.1 2.1 0.2 2.6 1.5 179 6 186 165 -1.4 0 -1.2 -1.7 01/16/2007 02:10:00 2.4 0.3 3 1.5 2.2 0.3 2.6 1.5 2.3 0.3 2.6 1.9 159 12 155 165 -1.7 0.2 -1.4 -2.1 01/16/2007 02:20:00 2.5 0.3 3.4 1.9 2.4 0.3 3 1.9 2.7 0.3 3.4 1.9 158 12 165 165 -2 0.1 -1.7 -2.4 01/16/2007 02:30:00 2.6 0.4 3.4 1.9 2.5 0.3 3 1.9 2.4 0.3 3 1.9 154 7 159 165 -2.5 0.2 -1.9 -2.8 01/16/2007 02:40:00 3 0.2 3.4 2.3 2.9 0.2 3.4 2.3 2.7 0.2 3 1.9 153 8 160 165 -2.6 0 -2.4 -2.8 01/16/2007 02:50:00 3 0.4 4.2 2.3 2.9 0.4 3.8 1.9 2.7 0.3 3.4 2.3 156 8 106 165 -2.1 0.2 -1.4 -2.6 01/16/2007 03:00:00 2.6 0.5 3.8 1.5 2.6 0.5 3.8 1.9 2.6 0.5 3.4 1.9 137 12 162 165 -1.7 0 -1.4 -1.9 01/16/2007 03:10:00 3.2 0.3 3.8 2.6 3.1 0.3 3.8 2.3 3.2 0.3 3.8 2.3 136 5 136 165 -2.2 0.2 -1.7 -2.6 01/16/2007 03:20:00 3.4 0.3 4.2 2.6 3.3 0.3 3.8 2.6 3.1 0.3 3.8 2.6 126 3 130 165 -3 0.3 -2.1 -3.5 01/16/2007 03:30:00 3.7 0.4 4.9 2.6 3.6 0.4 4.6 2.6 3.5 0.4 4.6 2.6 137 8 156 165 -3.2 0.2 -2.8 -3.5 01/16/2007 03:40:00 4.5 0.6 6.1 3 4.4 0.6 5.7 2.6 4.4 0.6 5.7 3 142 9 146 165 -2.6 0.1 -2.4 -2.8 01/16/2007 03:50:00 5 0.5 6.5 3.8 4.9 0.5 6.1 3.8 4.9 0.5 6.5 3.8 151 5 156 165 -2.5 0 -2.1 -2.8 01/16/2007 04:00:00 6.1 0.7 7.6 4.2 5.9 0.7 7.2 4.2 6.1 0.7 7.6 4.6 148 15 156 165 -2.6 0 -2.4 -2.8 01/16/2007 04:10:00 6.1 0.8 7.6 3.8 5.9 0.8 7.2 3.4 6 0.7 7.6 4.2 146 15 151 165 -2.8 0 -2.6 -3 01/16/2007 04:20:00 6.3 1.7 9.1 3 6.2 1.6 8.8 3 6.2 1.7 9.1 3.4 145 16 154 165 -2.4 0.1 -2.1 -2.8 01/16/2007 04:30:00 6 0.8 8 3.4 5.9 0.8 8 3.8 5.9 0.7 8 3.8 145 13 144 165 -2.5 0.1 -2.1 -2.8 01/16/2007 04:40:00 5.7 0.7 7.2 3.4 5.5 0.7 7.2 3.8 5.4 0.6 6.8 4.2 149 12 152 165 -2.9 0 -2.6 -3.3 01/16/2007 04:50:00 5.3 0.7 6.8 3.4 5.1 0.6 6.5 3 5.3 0.5 6.5 4.2 148 16 155 165 -2.5 0.1 -2.4 -2.8 01/16/2007 05:00:00 5.5 0.5 7.2 4.2 5.3 0.5 6.8 3.8 5.4 0.5 6.8 4.2 147 21 134 165 -2.5 0 -2.1 -2.6 01/16/2007 05:10:00 5.5 0.6 6.8 3.4 5.3 0.6 6.8 3.4 5.4 0.5 6.8 3.8 150 19 78 165 -2.5 0.1 -2.1 -2.8 01/16/2007 05:20:00 6.2 0.4 6.8 5.3 5.9 0.4 6.5 4.9 5.9 0.4 6.8 4.9 146 23 158 165 -2.5 0 -2.6 -2.8 01/16/2007 05:30:00 6 0.4 6.8 4.9 5.8 0.3 6.5 4.6 5.9 0.3 6.5 4.9 146 22 159 165 -2.6 0 -2.6 -2.8 01/16/2007 05:40:00 5.7 0.6 7.2 4.6 5.4 0.5 6.8 4.2 5.5 0.5 7.2 4.2 147 22 145 165 -2.6 0 -2.6 -2.8 01/16/2007 05:50:00 5.6 0.6 7.6 4.2 5.4 0.6 7.2 4.2 5.6 0.6 7.2 4.2 152 21 133 165 -2.5 0 -2.1 -2.6 01/16/2007 06:00:00 5.9 0.9 8 3.4 5.7 0.9 7.6 3.4 5.8 0.8 8 3.4 152 22 150 165 -2.5 0 -2.6 -2.8 01/16/2007 06:10:00 6.7 0.6 8.4 5.3 6.5 0.5 8 4.9 6.7 0.5 8.4 5.3 152 22 154 165 -2.5 0 -2.4 -2.8 01/16/2007 06:20:00 6.4 0.7 7.6 4.6 6.1 0.7 7.2 4.6 6.3 0.7 8 4.6 149 28 165 165 -2.5 0.1 -2.1 -2.8 01/16/2007 06:30:00 6.4 0.7 7.6 4.6 6.1 0.6 7.2 4.6 6.3 0.6 7.6 4.9 148 27 162 165 -2.5 0 -2.1 -2.6 01/16/2007 06:40:00 6.3 0.7 7.6 4.6 6.1 0.6 7.2 4.6 6.3 0.7 7.6 4.9 146 19 150 165 -2.4 0 -2.1 -2.6 01/16/2007 06:50:00 6.3 0.6 7.2 4.9 6.1 0.5 7.2 4.9 6.2 0.5 7.2 4.9 150 12 157 165 -2.5 0 -2.1 -2.6 01/16/2007 07:00:00 6.2 0.5 7.2 4.9 6 0.4 6.8 4.9 6.2 0.4 7.2 4.9 149 15 105 165 -2.3 0 -2.1 -2.6 01/16/2007 07:10:00 6 0.4 6.8 4.9 5.8 0.4 6.5 4.9 5.9 0.4 6.8 4.9 152 8 149 165 -2.4 0 -2.1 -2.6 01/16/2007 07:20:00 6.2 0.7 7.6 4.6 6 0.6 7.2 4.6 6 0.6 7.2 4.6 149 8 149 165 -2.2 0 -1.9 -2.6 01/16/2007 07:30:00 5.4 0.6 6.8 3.8 5.3 0.6 6.8 3.8 5.3 0.6 6.8 3.8 145 6 150 165 -2 0 -1.9 -2.1 01/16/2007 07:40:00 5.7 0.6 6.8 3.4 5.6 0.6 6.8 3.4 5.7 0.6 7.2 3.8 145 5 142 165 -2.1 0 -1.9 -2.1 01/16/2007 07:50:00 6.8 0.8 8.8 4.9 6.6 0.7 8.4 5.3 6.8 0.7 8.8 5.3 145 16 151 165 -2 0 -1.9 -2.1 01/16/2007 08:00:00 7.3 0.7 9.5 5.7 7.1 0.7 8.8 5.7 7.1 0.6 9.1 5.7 149 8 116 165 -2.2 0 -1.9 -2.6 01/16/2007 08:10:00 7.5 0.6 8.8 5.7 7.3 0.6 8.8 5.3 7.1 0.6 8.4 5.7 144 11 148 165 -2.2 0 -1.9 -2.6 01/16/2007 08:20:00 8.8 0.9 11.1 6.8 8.7 0.8 10.7 6.8 8.5 0.9 10.3 6.5 138 5 137 165 -1.3 0.2 -0.8 -1.9 01/16/2007 08:30:00 10.8 0.7 12.6 8.8 10.7 0.7 12.6 8.8 10.7 0.8 12.2 8.4 141 6 149 165 -0.9 0 -0.8 -1.2 01/16/2007 08:40:00 11.9 0.7 13.3 9.5 11.8 0.7 13.3 9.1 11.8 0.7 13.3 9.1 141 5 136 165 -0.9 0 -0.8 -1.2 01/16/2007 08:50:00 12.7 0.7 14.5 11.1 12.6 0.7 14.5 10.7 12.6 0.7 14.5 9.9 138 6 135 165 -0.8 0 -0.5 -0.8 01/16/2007 09:00:00 13.7 1 16.1 11.1 13.6 1.1 15.6 11.1 13.6 1.2 16.4 11.1 138 5 142 165 -0.6 0 -0.3 -0.8 01/16/2007 09:10:00 14.6 1 16.8 11.5 14.6 1 16.8 11.5 14.6 1.1 17.2 10.7 138 5 136 165 -0.3 0 -0.1 -0.5 01/16/2007 09:20:00 15.7 0.8 18.3 13.3 15.6 0.8 18.3 13.3 15.6 1 17.9 12.6 139 7 139 165 -0.2 0 -0.1 -0.3 01/16/2007 09:30:00 15.1 0.8 17.2 12.2 14.9 0.8 16.8 12.2 14.9 1 16.8 11.1 136 6 139 165 -0.3 0.1 -0.1 -0.5 01/16/2007 09:40:00 15.6 0.8 17.6 12.6 15.3 0.8 17.6 12.2 15.4 1 17.6 12.6 138 6 145 165 -0.3 0 -0.1 -0.5 01/16/2007 09:50:00 16.3 1 18.7 13 15.9 1 17.9 13 16 1.1 18.3 11.8 137 6 136 165 -0.2 0 -0.1 -0.3 01/16/2007 10:00:00 16.6 1.1 18.3 13 16.1 1 17.9 13 16.5 1 18.3 13.7 138 4 143 165 -0.1 0 0.2 -0.1 01/16/2007 10:10:00 15.2 1.3 18.3 11.8 14.7 1.3 17.6 11.1 14.8 1.3 17.6 11.5 137 0 137 165 0.1 0 0.2 -0.1 01/16/2007 10:20:00 14.8 0.9 16.8 11.8 14.4 0.9 16.4 11.1 14.7 1 17.2 9.9 137 0 137 165 0.1 0 0.2 -0.1 01/16/2007 10:30:00 14.2 1.2 17.2 10.7 13.8 1 16.8 10.7 13.9 1.1 16.4 10.7 137 0 137 165 0.2 0 0.2 -0.1 01/16/2007 10:40:00 13.9 1.5 16.4 10.3 13.7 1.3 16.1 10.3 13.7 1.5 16.8 9.9 137 0 137 165 0.2 0 0.4 0.2 01/16/2007 10:50:00 13.9 1 16.8 11.1 13.7 1 16.4 11.5 13.6 1 16.1 10.7 137 0 137 165 0.2 0 0.4 0.2 01/16/2007 11:00:00 13.2 0.9 16.1 10.3 13.1 0.9 16.1 9.9 13 1 15.6 9.5 137 0 136 165 0.2 0 0.4 0.2 01/16/2007 11:10:00 13.3 1.1 15.6 9.5 13.2 1.1 15.6 9.9 12.8 1.2 15.3 8.4 137 0 137 165 0.2 0 0.4 0.2 01/16/2007 11:20:00 13.4 1 16.1 11.1 13.3 1 16.1 11.1 13 1.1 15.6 9.9 137 0 136 165 0.2 0 0.7 0.2 01/16/2007 11:30:00 12 0.9 14.9 9.5 12 0.9 14.9 9.5 11.6 1.1 14.5 8 137 0 137 165 0.3 0 0.7 0.2 01/16/2007 11:40:00 11.9 1.1 14.1 9.1 11.8 1.1 14.1 8.8 11.5 1.3 14.5 8.4 137 0 136 165 0.3 0 0.7 0.2 01/16/2007 11:50:00 12.4 1.2 16.4 9.5 12.3 1.2 16.4 9.1 12.3 1.3 15.6 8.8 137 0 137 165 0.4 0 0.7 0.2 01/16/2007 12:00:00 12.1 1.1 15.3 9.1 12.1 1.1 15.6 9.5 12 1.2 16.1 9.1 137 0 137 165 0.4 0 0.7 0.2 01/16/2007 12:10:00 12.4 1.1 15.6 9.1 12.4 1.1 15.3 9.5 12.4 1.1 16.1 9.1 137 0 137 165 0.5 0 0.7 0.2 01/16/2007 12:20:00 12.6 1.3 16.1 8.8 12.4 1.3 15.6 9.1 12.5 1.3 15.6 9.1 137 0 136 165 0.5 0 0.7 0.2 01/16/2007 12:30:00 14.7 1.4 17.9 11.1 12.4 1.2 15.3 9.1 12.6 1.3 15.6 8.8 137 0 137 165 0.5 0 0.7 0.4 01/16/2007 12:40:00 13 1.1 16.4 10.3 11.9 1 14.5 7.6 11.3 1.1 14.5 8 137 0 137 165 0.5 0 0.7 0.4 01/16/2007 12:50:00 13.2 1.3 16.4 9.1 13 1.2 15.6 9.1 11.7 1.3 14.9 7.6 137 0 137 165 0.7 0 0.9 0.7 01/16/2007 13:00:00 13.5 1.3 16.4 9.9 13.2 1.2 16.1 9.9 12.1 1.3 14.9 7.6 137 0 137 165 0.8 0 0.9 0.7 01/16/2007 13:10:00 13.8 0.7 16.1 11.8 13.4 0.7 15.3 11.5 12.6 1 15.6 10.3 137 0 137 165 0.8 0 0.9 0.7 01/16/2007 13:20:00 13.5 0.7 15.3 11.5 13.2 0.6 14.9 10.7 14.3 0.9 16.4 11.5 137 0 137 165 0.9 0 1.1 0.9 01/16/2007 13:30:00 13.6 0.9 15.6 11.1 13.6 1 16.1 11.5 14.7 1.2 17.6 11.5 137 0 137 165 0.9 0 1.1 0.9 01/16/2007 13:40:00 12 1 15.3 9.5 12.2 1 14.5 9.9 13.2 1 15.6 10.7 137 0 137 165 0.9 0 1.1 0.9 01/16/2007 13:50:00 14.1 0.9 16.1 11.5 14.2 0.9 16.1 11.5 15.4 1.1 17.6 12.2 137 0 137 165 1.2 0.1 1.4 0.9 01/16/2007 14:00:00 13.5 1.1 16.1 11.1 13.8 1.2 16.8 11.5 14.8 1.4 18.3 11.8 137 0 136 165 1.4 0 1.6 1.4 01/16/2007 14:10:00 13.2 1.2 16.1 10.7 13.5 1.3 15.6 10.7 14.7 1.3 17.2 11.5 137 0 137 165 1.4 0 1.6 1.4 01/16/2007 14:20:00 13.2 0.9 14.9 10.7 13.2 1 15.3 10.7 14.2 1.1 16.4 11.5 137 0 136 165 1.4 0 1.6 1.4 01/16/2007 14:30:00 11.7 0.8 13.7 9.5 11.5 1 13.7 8.8 12.4 1.1 14.9 9.1 137 0 137 165 1.4 0 1.6 1.4 01/16/2007 14:40:00 12.2 0.8 14.1 9.9 7.9 1 13.3 7.2 12.6 1 14.9 9.9 137 0 137 165 1.5 0 1.6 1.4 01/16/2007 14:50:00 11.3 0.6 13 9.5 7.4 0.2 7.6 6.8 11.4 0.7 13 9.5 137 0 137 165 1.5 0 1.8 1.4 01/16/2007 15:00:00 11.9 0.6 13.7 9.9 7.5 0.2 8 6.8 11.9 0.8 13.7 9.1 137 1 137 165 1.5 0 1.6 1.4 01/16/2007 15:10:00 10.7 0.7 12.6 8.8 7.3 0.2 7.6 6.1 10.7 0.7 12.2 9.1 136 0 136 165 1.5 0 1.6 1.4 01/16/2007 15:20:00 11.3 0.6 12.6 9.1 7.4 0.2 7.6 6.5 10.8 0.7 12.6 8.8 136 0 136 165 1.5 0 1.6 1.4 01/16/2007 15:30:00 11.6 0.6 13 9.1 7.3 0.2 7.6 6.5 11.3 0.8 12.6 8.8 136 0 136 165 1.5 0 1.6 1.4 01/16/2007 15:40:00 11 0.8 13 8.8 7.2 0.3 7.6 6.5 10.7 0.8 12.6 8.8 136 0 136 165 1.5 0 1.6 1.4 01/16/2007 15:50:00 9.6 0.5 11.1 8.4 6.9 0.2 7.2 6.5 9.5 0.4 10.3 8.4 136 0 136 165 1.4 0 1.6 1.4 01/16/2007 16:00:00 8.9 0.9 10.7 6.8 6.7 0.3 7.2 5.3 9.1 0.9 10.7 6.8 136 0 136 165 1.4 0 1.8 1.4 01/16/2007 16:10:00 7.9 0.6 9.1 6.1 6.4 0.4 7.2 5.3 8.3 0.6 9.5 6.5 136 0 136 165 1.4 0 1.6 1.4 01/16/2007 16:20:00 8.8 0.7 10.3 6.8 6.8 0.3 7.2 5.7 9.3 0.6 10.7 7.2 136 0 136 165 1.3 0 1.4 1.1 01/16/2007 16:30:00 8 0.6 9.1 6.8 6.4 0.3 6.8 5.7 8.5 0.6 9.9 6.8 136 0 136 165 1.1 0 1.4 0.9 01/16/2007 16:40:00 6.2 0.8 7.6 3.8 6 0.4 6.5 4.9 7.8 0.6 9.1 6.1 136 0 136 165 1.1 0 1.4 0.9 01/16/2007 16:50:00 5.3 0.5 6.1 3.8 5.7 0.5 6.5 4.2 7.3 0.7 9.1 6.1 136 0 136 165 0.8 0.1 1.4 0.7 01/16/2007 17:00:00 3.7 0.7 4.9 2.6 4.4 0.6 5.7 3 5.5 0.9 7.2 3.8 136 0 136 165 0.8 0 0.9 0.7 01/16/2007 17:10:00 3.1 0.5 4.2 2.3 4.1 0.5 5.3 2.6 5 0.6 6.1 3.4 136 0 136 165 0.7 0 0.9 0.7 01/16/2007 17:20:00 2.9 0.3 4.2 2.3 3.8 0.4 4.9 2.6 4.8 0.4 6.1 3.8 136 0 136 165 0.7 0 0.9 0.7 01/16/2007 17:30:00 2.1 0.4 3 1.1 2.8 0.4 3.8 1.9 3.5 0.5 4.6 2.3 136 0 136 165 0.6 0 0.9 0.4 01/16/2007 17:40:00 0.7 0.5 1.9 0.4 1.5 1 3 0.4 2.4 0.5 3.8 1.1 136 0 136 165 0.5 0 0.9 0.4 01/16/2007 17:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 1 0.8 2.6 0.4 136 0 165 165 0.5 0 0.7 0.4 01/16/2007 18:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 136 0 165 165 0.4 0 0.7 0.2 01/16/2007 18:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 136 0 165 165 0.2 0 0.7 0.2 01/16/2007 18:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 136 0 165 165 0.2 0 0.4 0.2 01/16/2007 18:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 136 0 165 165 0.2 0 0.4 -0.1 01/16/2007 18:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 136 0 165 165 0.2 0 0.4 0.2 01/16/2007 18:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 136 0 165 165 0.2 0 0.4 0.2 01/16/2007 19:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 136 0 165 165 0.2 0 0.4 0.2 01/16/2007 19:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 136 0 165 165 0.2 0 0.4 0.2 01/16/2007 19:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 136 0 165 165 0.2 0 0.4 0.2 01/16/2007 19:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 136 0 165 165 0.3 0 0.7 0.2 01/16/2007 19:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 136 0 165 165 0.3 0 0.7 0.2 01/16/2007 19:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 136 0 165 165 0.3 0 0.7 0.2 01/16/2007 20:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 136 0 165 165 0.3 0 0.7 0.2 01/16/2007 20:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 136 0 165 165 0.4 0 0.7 0.2 01/16/2007 20:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 136 0 165 165 0.5 0 0.7 0.2 01/16/2007 20:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 136 0 165 165 0.5 0 0.7 0.2 01/16/2007 20:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 136 0 165 165 0.4 0 0.7 0.2 01/16/2007 20:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 136 0 165 165 0.4 0 0.7 0.2 01/16/2007 21:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 136 0 165 165 0.4 0 0.7 0.2 01/16/2007 21:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 136 0 165 165 0.5 0 0.9 0.2 01/16/2007 21:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 136 0 165 165 0.7 0 0.9 0.7 01/16/2007 21:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 136 0 165 165 1 0 1.4 0.9 01/16/2007 21:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 136 0 165 165 1.2 0 1.4 0.9 01/16/2007 21:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 136 0 165 165 1.2 0 1.4 0.9 01/16/2007 22:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 136 0 165 165 1.2 0 1.4 1.1 01/16/2007 22:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 136 0 165 165 1.2 0 1.4 1.1 01/16/2007 22:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 136 0 165 165 1.3 0 1.4 1.1 01/16/2007 22:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 136 0 165 165 1.4 0 1.6 1.1 01/16/2007 22:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 136 0 165 165 1.4 0 1.6 1.4 01/16/2007 22:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 136 0 165 165 1.4 0 1.6 1.4 01/16/2007 23:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 136 0 165 165 1.3 0 1.6 1.4 01/16/2007 23:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 136 0 165 165 1.3 0 1.4 1.1 01/16/2007 23:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 136 0 165 165 1.2 0 1.4 0.9 01/16/2007 23:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 136 0 165 165 1.2 0 1.4 0.9 01/16/2007 23:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 136 0 165 165 1.2 0 1.4 1.1 01/16/2007 23:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 136 0 165 165 1.3 0 1.4 1.4 01/17/2007 00:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 136 0 165 165 1.3 0 1.6 1.1 01/17/2007 00:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 136 0 165 165 1.4 0 1.6 1.1 01/17/2007 00:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 136 0 165 165 1.4 0 1.6 1.4 01/17/2007 00:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 136 0 165 165 1.4 0 1.6 1.4 01/17/2007 00:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 136 0 165 165 1.4 0 1.6 1.4 01/17/2007 00:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 136 0 165 165 1.4 0 1.6 1.4 01/17/2007 01:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 136 0 165 165 1.4 0 1.6 1.4 01/17/2007 01:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 136 0 165 165 1.4 0 1.6 1.4 01/17/2007 01:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 136 0 165 165 1.3 0 1.4 1.1 01/17/2007 01:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 136 0 165 165 1.2 0 1.4 1.1 01/17/2007 01:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 136 0 165 165 1.2 0 1.4 0.9 01/17/2007 01:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 136 0 165 165 1.2 0 1.4 0.9 01/17/2007 02:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 136 0 165 165 1.2 0 1.4 0.9 01/17/2007 02:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 136 0 165 165 0.9 0 1.4 0.7 01/17/2007 02:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 136 0 165 165 1.1 0 1.4 0.9 01/17/2007 02:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 136 0 165 165 1 0 1.4 0.9 01/17/2007 02:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 136 0 165 165 1 0 1.4 0.9 01/17/2007 02:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 136 0 165 165 1 0 1.1 0.9 01/17/2007 03:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 136 0 165 165 1 0 1.1 0.9 01/17/2007 03:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 136 0 165 165 0.8 0.1 1.1 0.7 01/17/2007 03:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 136 0 165 165 0.8 0.1 0.9 0.7 01/17/2007 03:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 136 0 165 165 0.9 0 1.1 0.7 01/17/2007 03:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 136 0 165 165 1 0 1.4 0.9 01/17/2007 03:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 136 0 165 165 0.9 0.1 1.1 0.7 01/17/2007 04:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 136 0 165 165 0.8 0 0.9 0.7 01/17/2007 04:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 136 0 165 165 0.7 0 1.1 0.4 01/17/2007 04:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 136 0 165 165 0.7 0.1 0.9 0.4 01/17/2007 04:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 136 0 165 165 0.8 0 0.9 0.7 01/17/2007 04:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 136 0 165 165 0.8 0 0.9 0.7 01/17/2007 04:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 136 0 165 165 0.8 0 0.9 0.7 01/17/2007 05:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 136 0 165 165 0.8 0 0.9 0.7 01/17/2007 05:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 136 0 165 165 0.8 0 0.9 0.7 01/17/2007 05:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 136 0 165 165 0.8 0 1.1 0.7 01/17/2007 05:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 136 0 165 165 0.5 0.1 0.9 0.2 01/17/2007 05:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 136 0 165 165 0.1 0 0.2 -0.1 01/17/2007 05:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 136 0 165 165 0.2 0.1 0.7 -0.1 01/17/2007 06:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 136 0 165 165 0.5 0 0.7 0.2 01/17/2007 06:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 136 0 165 165 0.2 0 0.7 -0.1 01/17/2007 06:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 136 0 165 165 0.1 0 0.2 -0.1 01/17/2007 06:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 136 0 165 165 -0.1 0 0.2 -0.1 01/17/2007 06:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 136 0 165 165 0.2 0.1 0.7 0.2 01/17/2007 06:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 136 0 165 165 0.2 0 0.4 -0.1 01/17/2007 07:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 136 0 165 165 -0.1 0 0.2 -0.3 01/17/2007 07:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 136 0 165 165 -0.2 0 -0.1 -0.3 01/17/2007 07:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 136 0 165 165 -0.3 0 -0.1 -0.5 01/17/2007 07:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 136 0 165 165 -0.3 0 -0.1 -0.5 01/17/2007 07:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 136 0 165 165 -0.2 0 -0.1 -0.5 01/17/2007 07:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 136 0 165 165 -0.3 0 -0.3 -0.5 01/17/2007 08:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 136 0 165 165 -0.3 0 -0.1 -0.5 01/17/2007 08:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 136 0 165 165 -0.1 0 0.2 -0.3 01/17/2007 08:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 136 0 165 165 0.1 0 0.2 -0.1 01/17/2007 08:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 136 0 165 165 0.2 0 0.4 0.2 01/17/2007 08:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 136 0 165 165 0.3 0 0.7 0.2 01/17/2007 08:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 136 0 165 165 0.4 0 0.7 0.2 01/17/2007 09:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 136 0 165 165 0.6 0 0.7 0.4 01/17/2007 09:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 136 0 165 165 0.4 0 0.7 0.2 01/17/2007 09:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 136 0 165 165 0.3 0 0.7 0.2 01/17/2007 09:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 136 0 165 165 0.3 0 0.7 0.2 01/17/2007 09:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 136 0 165 165 0.4 0 0.7 0.2 01/17/2007 09:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 136 0 165 165 0.5 0 0.7 0.2 01/17/2007 10:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 136 0 165 165 0.6 0 0.9 0.4 01/17/2007 10:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 136 0 165 165 0.7 0 0.9 0.7 01/17/2007 10:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 136 0 165 165 0.8 0 1.1 0.7 01/17/2007 10:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 136 0 165 165 0.9 0 1.1 0.9 01/17/2007 10:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 136 0 165 165 0.9 0 1.1 0.9 01/17/2007 10:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 136 0 165 165 1 0 1.1 0.9 01/17/2007 11:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 136 0 165 165 1 0 1.4 0.9 01/17/2007 11:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 136 0 165 165 1.1 0 1.4 0.9 01/17/2007 11:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 136 0 165 165 1 0 1.4 0.9 01/17/2007 11:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 136 0 165 165 0.9 0 1.1 0.9 01/17/2007 11:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 136 0 165 165 0.9 0 1.4 0.9 01/17/2007 11:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 124 19 165 165 1.3 0.1 1.6 0.9 01/17/2007 12:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 98 3 165 165 1.4 0 1.6 1.4 01/17/2007 12:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.7 0.4 98 8 165 165 1.5 0.1 1.8 1.4 01/17/2007 12:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 124 6 165 165 2.3 0 2.6 1.8 01/17/2007 12:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 123 4 165 165 2.1 0.2 2.6 1.8 01/17/2007 12:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 122 5 165 165 1.8 0 1.8 1.6 01/17/2007 12:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 126 4 165 165 1.8 0 1.8 1.6 01/17/2007 13:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 129 6 165 165 1.9 0 2.6 1.8 01/17/2007 13:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 129 7 165 165 1.9 0 2.1 1.8 01/17/2007 13:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 126 7 165 165 1.8 0 1.8 1.6 01/17/2007 13:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 1.7 0.6 3 0.4 128 8 165 165 1.8 0 1.8 1.6 01/17/2007 13:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 1.9 0.4 3 1.1 133 6 165 165 1.8 0 1.8 1.6 01/17/2007 13:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 2.4 0.3 3 1.9 141 5 165 165 1.7 0 1.8 1.6 01/17/2007 14:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 2.5 0.4 3.8 1.5 140 6 165 165 1.7 0 1.8 1.6 01/17/2007 14:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 3.1 0.4 4.2 2.3 135 5 165 165 1.6 0 1.8 1.6 01/17/2007 14:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 2.8 0.4 3.8 1.5 132 5 165 165 1.7 0 1.8 1.6 01/17/2007 14:30:00 1 0.4 1.9 0.4 0.4 0 0.4 0.4 2.4 0.4 3 1.5 130 6 135 165 1.7 0 1.8 1.6 01/17/2007 14:40:00 1.2 0.4 2.3 0.4 0.4 0 0.4 0.4 2.5 0.4 3.4 1.9 123 5 114 165 1.8 0 1.8 1.6 01/17/2007 14:50:00 0.4 0.2 1.1 0.4 0.4 0 0.4 0.4 2.2 0.3 3.4 1.5 134 7 142 165 1.7 0 1.8 1.6 01/17/2007 15:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 1.9 0.3 2.6 1.1 133 5 165 165 1.7 0 1.8 1.6 01/17/2007 15:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 1.8 0.2 2.3 1.1 135 4 165 165 1.7 0 1.8 1.6 01/17/2007 15:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 1.3 0.4 2.3 0.4 126 5 165 165 1.7 0 1.8 1.6 01/17/2007 15:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 2.3 0.3 3 1.5 121 6 165 165 1.8 0 1.8 1.6 01/17/2007 15:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 2.3 0.3 2.6 1.5 122 4 165 165 1.7 0 1.8 1.6 01/17/2007 15:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 1.9 0.8 3.8 0.4 121 8 165 165 1.7 0 1.8 1.6 01/17/2007 16:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 3.8 0.8 5.7 1.5 108 6 165 165 1.7 0 1.8 1.6 01/17/2007 16:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 3.8 1 5.7 0.4 108 8 165 165 1.7 0 1.8 1.4 01/17/2007 16:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 8.1 1.7 10.3 4.2 102 5 165 165 1.7 0 1.8 1.6 01/17/2007 16:30:00 0.4 0 0.4 0.4 1.5 1.1 3 0.4 8.5 0.7 9.9 6.5 100 3 165 165 1.7 0 1.8 1.6 01/17/2007 16:40:00 0.7 0.9 3.4 0.4 2.6 0.2 3 2.3 8.8 0.8 10.7 6.5 105 4 110 165 1.7 0 1.8 1.6 01/17/2007 16:50:00 2.9 0.4 3.8 1.5 2.6 0.3 3 1.5 8.4 0.8 10.3 5.7 102 4 104 165 1.7 0 1.8 1.6 01/17/2007 17:00:00 2.5 0.4 3 1.5 2.4 0.3 3 1.5 7.7 0.8 9.5 4.9 109 5 109 165 1.6 0 1.8 1.6 01/17/2007 17:10:00 3.3 0.6 4.6 2.3 2.6 0.2 3 1.9 8.1 0.7 9.1 5.7 108 5 106 165 1.6 0 1.8 1.6 01/17/2007 17:20:00 3.9 0.3 4.6 3 2.5 0.2 3 1.9 8.1 0.7 9.5 6.1 115 4 112 165 1.6 0 1.8 1.6 01/17/2007 17:30:00 4 0.3 4.6 3 2.6 0.2 3 1.9 8.2 0.7 9.5 5.7 117 3 109 165 1.6 0 1.8 1.6 01/17/2007 17:40:00 4 0.5 5.3 3 2.6 0.3 3.4 1.9 8.4 0.7 10.3 6.1 119 4 119 165 1.6 0 1.8 1.6 01/17/2007 17:50:00 4 0.5 5.3 3 2.5 0.3 3.4 1.5 8.2 0.7 10.3 6.5 122 3 118 165 1.7 0 1.8 1.6 01/17/2007 18:00:00 3.6 0.5 4.9 2.3 2.3 0.4 3 1.1 7.6 0.8 9.5 5.7 118 3 121 165 1.7 0 1.8 1.6 01/17/2007 18:10:00 3.4 0.5 4.6 2.3 2.2 0.4 3 1.5 7.1 0.8 8.8 4.6 118 4 121 165 1.6 0 1.8 1.4 01/17/2007 18:20:00 3.8 0.3 4.6 3 2.5 0.2 3 1.9 7.9 0.5 9.1 6.5 119 3 119 165 1.6 0 1.8 1.4 01/17/2007 18:30:00 3.6 0.3 4.6 2.6 2.3 0.2 2.6 1.5 7.5 0.4 8.4 6.1 121 3 121 165 1.6 0 1.8 1.4 01/17/2007 18:40:00 3.4 0.3 4.6 2.6 2.2 0.3 3 1.5 7.4 0.6 8.8 4.9 121 4 123 165 1.6 0 1.8 1.6 01/17/2007 18:50:00 2.9 0.4 3.8 1.9 1.7 0.3 2.3 0.7 6.8 0.5 8 4.9 122 4 123 165 1.7 0 1.8 1.6 01/17/2007 19:00:00 3.3 0.3 4.2 2.3 2 0.2 2.6 1.1 7.1 0.5 8.4 5.3 117 4 116 165 1.7 0 1.8 1.6 01/17/2007 19:10:00 3.2 0.3 3.8 2.6 1.9 0.2 2.6 1.5 7.2 0.4 8.4 6.1 113 4 118 165 1.7 0 1.8 1.6 01/17/2007 19:20:00 3.3 0.4 4.2 2.6 2 0.3 2.6 1.5 7.1 0.7 9.5 5.3 113 5 111 165 1.7 0 1.8 1.6 01/17/2007 19:30:00 3.3 0.3 3.8 2.3 2 0.2 2.6 1.5 7.1 0.4 8.8 5.3 116 4 115 165 1.8 0 1.8 1.6 01/17/2007 19:40:00 3.4 0.3 4.2 2.6 2.1 0.2 2.6 1.5 7.2 0.5 8.4 5.7 119 4 117 165 1.7 0 1.8 1.6 01/17/2007 19:50:00 3.6 0.2 4.6 2.6 2.4 0.2 2.6 1.5 7.7 0.4 8.4 6.1 124 5 121 165 1.8 0 1.8 1.6 01/17/2007 20:00:00 3.5 0.4 4.6 2.6 2.3 0.3 3 1.9 7.4 0.6 8.8 5.7 126 4 132 165 1.8 0 1.8 1.6 01/17/2007 20:10:00 3.2 0.3 3.8 2.3 2.1 0.3 2.6 1.1 7.1 0.4 8 5.3 115 4 122 165 1.8 0 1.8 1.6 01/17/2007 20:20:00 3.1 0.3 3.8 2.3 2.1 0.3 2.6 1.1 7 0.4 7.6 4.9 110 2 111 165 1.8 0 1.8 1.6 01/17/2007 20:30:00 2.7 0.4 3.4 1.9 1.8 0.4 2.6 1.1 6.5 0.5 7.6 5.3 103 4 106 165 1.8 0 1.8 1.6 01/17/2007 20:40:00 3.1 0.4 3.8 2.3 2.3 0.3 2.6 1.5 6.9 0.5 8 5.7 98 3 92 165 1.8 0 1.8 1.6 01/17/2007 20:50:00 1.9 0.5 3 0.7 0.8 0.6 1.9 0.4 5.7 0.5 6.8 4.6 87 6 95 165 1.8 0 1.8 1.6 01/17/2007 21:00:00 2.6 1.1 4.6 0.4 1.4 1.1 3 0.4 6.4 1 8.8 4.9 84 6 90 165 1.8 0 1.8 1.6 01/17/2007 21:10:00 3.4 0.8 4.6 1.1 2.7 0.5 3.4 1.1 7.1 1.1 9.1 4.6 77 9 88 165 1.8 0 2.3 1.6 01/17/2007 21:20:00 3 0.7 4.6 1.5 3.2 0.9 4.9 1.5 6.4 0.8 9.1 4.9 73 9 85 165 1.7 0 1.8 1.6 01/17/2007 21:30:00 3.2 0.8 4.6 1.1 3.8 0.7 4.9 2.3 6.6 1 8.4 4.2 74 6 80 165 1.7 0 1.8 1.6 01/17/2007 21:40:00 3.9 0.5 4.9 2.3 4.6 0.5 5.7 3 7.3 0.7 8.8 5.7 80 5 81 165 1.8 0 1.8 1.6 01/17/2007 21:50:00 3.3 0.6 4.6 1.5 4 0.5 5.3 2.6 6.6 0.7 8.8 4.9 68 9 78 165 1.7 0 1.8 1.6 01/17/2007 22:00:00 2.9 0.6 3.8 0.7 3.6 0.6 4.6 1.9 6.3 0.7 7.6 4.6 59 8 55 165 1.7 0 1.8 1.6 01/17/2007 22:10:00 3.3 0.7 4.9 1.1 4 0.7 5.7 2.3 6.6 0.8 9.1 4.2 48 7 46 165 1.6 0 1.8 1.4 01/17/2007 22:20:00 3.6 0.5 4.9 2.6 4.2 0.5 5.7 3 7 0.6 9.1 5.3 38 6 46 165 1.5 0 1.6 1.4 01/17/2007 22:30:00 3.1 0.6 4.2 1.9 3.8 0.5 4.9 2.6 6.6 0.7 8.4 4.6 36 5 33 165 1.5 0 1.6 1.4 01/17/2007 22:40:00 3.8 0.4 4.6 2.6 4.5 0.4 5.3 3.4 7.4 0.6 8.8 5.7 34 3 38 165 1.5 0 1.6 1.4 01/17/2007 22:50:00 3.2 0.7 4.6 0.7 3.8 0.7 4.9 1.9 6.7 0.8 8 4.6 29 1 31 165 1.5 0 1.6 1.4 01/17/2007 23:00:00 3.1 0.5 4.2 1.9 3.8 0.5 4.6 2.3 6.5 0.6 7.6 4.6 30 1 29 165 1.5 0 1.6 1.4 01/17/2007 23:10:00 2.9 0.6 4.2 1.5 3.4 0.6 4.6 1.9 6.1 0.6 7.6 4.6 32 0 31 165 1.5 0 1.6 1.4 01/17/2007 23:20:00 2.4 0.6 3.8 0.7 3 0.6 4.2 1.5 5.7 0.7 6.8 4.2 33 0 33 165 1.5 0 1.6 1.4 01/17/2007 23:30:00 1.2 1.1 4.2 0.4 3 0.7 4.6 0.7 5.6 0.7 7.6 3.8 33 0 33 165 1.5 0 1.8 1.4 01/17/2007 23:40:00 0.4 0 0.4 0.4 2.8 0.5 3.8 0.7 5.4 0.7 6.8 3.4 33 0 165 165 1.5 0 1.6 1.4 01/17/2007 23:50:00 0.4 0 0.4 0.4 3.1 0.4 3.8 1.9 5.8 0.5 7.2 3.8 33 0 165 165 1.5 0 1.8 1.4 01/18/2007 00:00:00 0.4 0 0.4 0.4 3.6 0.5 4.9 2.3 6.4 0.7 8.8 4.9 33 0 165 165 1.5 0 1.6 1.4 01/18/2007 00:10:00 0.4 0 0.4 0.4 4.1 0.5 5.3 2.6 6.8 0.7 8.8 4.9 32 0 165 165 1.5 0 1.8 1.4 01/18/2007 00:20:00 0.4 0 0.4 0.4 1.7 1.5 4.9 0.4 6.7 0.8 8.8 4.9 29 1 165 165 1.6 0 1.8 1.6 01/18/2007 00:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 5.8 0.6 7.2 4.6 27 0 165 165 1.7 0 1.8 1.6 01/18/2007 00:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 6 0.7 8.4 4.6 27 0 165 165 1.7 0 1.8 1.6 01/18/2007 00:50:00 1.9 2.1 5.3 0.4 0.4 0 0.4 0.4 8.3 1 11.1 5.7 22 2 20 165 1.8 0 1.8 1.6 01/18/2007 01:00:00 4.1 0.5 5.3 2.6 0.4 0 0.4 0.4 8.1 0.8 10.7 5.7 14 1 16 165 1.8 0 2.1 1.6 01/18/2007 01:10:00 3.2 0.8 4.9 1.1 0.4 0 0.4 0.4 6.6 1.3 9.5 3.8 16 7 13 165 1.8 0 1.8 1.6 01/18/2007 01:20:00 2.1 0.9 3.4 0.4 2.2 1.2 4.2 0.4 5.4 0.8 7.2 3.4 20 8 20 165 1.8 0 1.8 1.6 01/18/2007 01:30:00 1.4 1 3 0.4 2.4 0.7 3.4 0.4 5 0.6 6.8 3 19 8 20 165 1.8 0 1.8 1.6 01/18/2007 01:40:00 2.9 0.5 4.6 1.1 3.3 0.6 5.3 1.9 6.2 0.9 8 3.8 18 8 26 165 1.8 0 1.8 1.8 01/18/2007 01:50:00 3.7 0.4 4.6 2.6 3.6 0.7 4.9 1.5 6.9 0.7 8.8 4.9 12 8 28 165 1.9 0 1.8 1.8 01/18/2007 02:00:00 3.7 0.5 4.9 2.6 3.6 0.7 4.9 2.3 7 0.7 9.1 4.9 14 7 15 165 1.9 0 2.1 1.8 01/18/2007 02:10:00 3.3 0.5 4.6 2.3 3 0.8 4.6 0.4 6.4 0.7 8.4 4.6 11 6 14 165 1.8 0 1.8 1.6 01/18/2007 02:20:00 4 0.5 5.3 2.3 4 1.5 8.8 1.5 6.8 0.6 8.8 5.3 9 6 5 165 1.8 0 2.1 1.6 01/18/2007 02:30:00 3.8 0.5 5.7 2.6 5.7 1.1 8.4 3.4 6.5 0.8 8.8 4.2 12 7 6 165 1.8 0 1.8 1.6 01/18/2007 02:40:00 3.5 0.6 5.3 1.5 5.8 0.9 8.4 3.4 6.1 0.8 8.8 4.2 17 7 18 165 1.8 0 1.8 1.6 01/18/2007 02:50:00 3.2 0.5 4.6 1.9 5.7 1 8 3 6.1 0.7 7.6 3.8 22 8 28 165 1.9 0 1.8 1.8 01/18/2007 03:00:00 3.5 0.5 4.6 2.3 6.2 0.8 8.4 3.8 6.3 0.7 8 4.2 19 7 21 165 1.9 0 1.8 1.8 01/18/2007 03:10:00 2.5 0.7 4.2 0.4 5.2 0.9 7.2 3.4 5.2 0.8 7.6 3.4 28 8 37 165 1.9 0 1.8 1.8 01/18/2007 03:20:00 2.4 1 4.2 0.4 5.4 1.1 7.6 3 5.3 1.1 7.6 3.4 39 7 39 165 1.8 0 1.8 1.6 01/18/2007 03:30:00 3.1 0.8 4.6 1.1 6 1.1 8 3.8 5.8 1 8.4 3.8 42 8 43 165 1.7 0 1.8 1.6 01/18/2007 03:40:00 2.9 0.8 4.9 0.7 5.8 1.1 8.4 3.4 5.6 1 8 3.8 43 7 39 165 1.5 0 1.8 1.4 01/18/2007 03:50:00 1.7 1 4.2 0.4 4.8 0.8 7.2 3 4.7 0.7 6.1 3 46 9 46 165 1.6 0 1.8 1.4 01/18/2007 04:00:00 1.6 1 3.4 0.4 4.7 0.8 6.5 2.6 4.4 0.8 6.1 2.6 53 6 53 165 1.5 0 1.8 1.4 01/18/2007 04:10:00 0.6 0.8 4.6 0.4 3.5 1 6.8 1.9 3.5 0.8 6.8 1.9 52 11 36 165 1.5 0 1.8 1.4 01/18/2007 04:20:00 3.5 1.7 6.1 0.4 6.5 1.8 10.3 2.6 5.9 1.7 9.5 2.3 68 10 73 165 1.4 0 1.8 1.4 01/18/2007 04:30:00 4.3 0.9 6.5 1.9 7.1 1.1 9.9 4.6 5.5 1 8.4 3 73 0 73 165 1.4 0 1.6 1.4 01/18/2007 04:40:00 2.6 1.3 6.5 0.4 5.6 1.2 9.9 3 4.3 1.2 8.8 1.5 73 0 73 165 1.4 0 1.6 1.4 01/18/2007 04:50:00 4.1 0.9 6.1 1.9 6.9 1 9.5 4.6 6.2 1 8.8 3.4 72 0 73 165 1.4 0 1.6 1.4 01/18/2007 05:00:00 3.4 0.9 5.7 0.7 6.1 1 8.8 3.4 5.6 0.8 8 3.8 72 0 73 165 1.4 0 1.6 1.4 01/18/2007 05:10:00 3.4 0.8 4.9 0.4 6.2 0.8 8 3.4 5.8 0.8 7.6 3.4 73 0 73 165 1.1 0 1.4 0.9 01/18/2007 05:20:00 2.5 1.2 4.9 0.4 5.5 1 8.4 3 5.2 0.9 7.6 3 72 0 73 165 1.1 0 1.4 0.9 01/18/2007 05:30:00 2.1 1.2 4.6 0.4 5.1 1.1 7.6 3 4.7 0.9 7.2 2.6 72 0 73 165 1 0 1.1 0.9 01/18/2007 05:40:00 2.7 1.1 4.6 0.4 5.6 0.9 7.6 2.6 5.1 0.8 6.8 2.6 72 0 73 165 1 0 1.4 0.9 01/18/2007 05:50:00 1.7 0.6 3 0.4 4.7 0.4 6.1 3.4 3.7 0.7 5.7 1.9 72 0 73 165 0.9 0 1.4 0.9 01/18/2007 06:00:00 0.7 0.6 2.3 0.4 4.1 0.6 5.3 1.5 3.5 0.5 4.6 2.3 72 0 73 165 0.8 0 1.1 0.7 01/18/2007 06:10:00 0.4 0 0.4 0.4 3.5 0.7 4.6 1.5 2.3 1.3 4.2 0.4 72 0 165 165 0.8 0 1.1 0.7 01/18/2007 06:20:00 0.4 0 0.4 0.4 3.4 1 5.3 0.7 0.4 0 0.4 0.4 72 0 165 165 0.9 0 1.4 0.9 01/18/2007 06:30:00 0.4 0 0.4 0.4 3.6 1 6.8 1.9 0.4 0 0.4 0.4 72 0 165 165 0.9 0 1.1 0.9 01/18/2007 06:40:00 0.4 0 0.4 0.4 4.4 1 7.2 2.3 0.4 0 0.4 0.4 72 0 165 165 1 0 1.1 0.9 01/18/2007 06:50:00 0.4 0 0.4 0.4 2.8 0.6 4.9 0.7 0.4 0 0.4 0.4 72 0 165 165 0.9 0 1.1 0.9 01/18/2007 07:00:00 0.4 0 0.4 0.4 3.8 1 5.3 1.5 0.4 0 0.4 0.4 72 0 165 165 0.9 0 1.1 0.9 01/18/2007 07:10:00 0.4 0 0.4 0.4 4.5 0.8 6.1 2.3 0.4 0 0.4 0.4 72 0 165 165 0.9 0 1.1 0.9 01/18/2007 07:20:00 0.4 0 0.4 0.4 6.7 1 9.9 4.2 0.4 0 0.4 0.4 72 0 165 165 0.9 0 1.1 0.9 01/18/2007 07:30:00 2.9 1.4 5.7 0.4 6.4 1.1 9.1 3.8 0.4 0 0.4 0.4 72 0 73 165 1 0 1.1 0.9 01/18/2007 07:40:00 4.1 0.7 5.7 2.3 5.9 1.6 9.9 2.6 0.4 0 0.4 0.4 72 0 73 165 1 0 1.1 0.9 01/18/2007 07:50:00 3.9 1.2 6.5 1.5 6.5 1.7 9.9 3 0.4 0 0.4 0.4 72 0 73 165 0.9 0 1.1 0.9 01/18/2007 08:00:00 4.5 0.7 6.8 2.6 7.4 1 10.7 5.3 0.4 0 0.4 0.4 72 0 72 165 0.9 0 1.1 0.9 01/18/2007 08:10:00 5.4 0.7 7.2 3.8 8.4 1.1 12.2 6.1 0.4 0 0.4 0.4 72 0 73 165 0.9 0 1.1 0.9 01/18/2007 08:20:00 6 0.8 7.6 3.8 9.4 1.4 13.3 5.7 0.9 2.4 12.6 0.4 72 0 73 165 1 0 1.4 0.9 01/18/2007 08:30:00 6.8 0.6 7.6 4.6 11 1.7 14.5 6.5 10.8 1.7 14.9 6.5 72 0 72 165 1 0 1.4 0.9 01/18/2007 08:40:00 6.6 0.5 7.6 4.9 10.5 1.1 13 7.6 9.9 1 12.2 7.6 72 0 72 165 1.1 0 1.4 0.9 01/18/2007 08:50:00 6.8 0.5 8 4.9 11.4 1.4 14.5 7.2 10.8 1.5 14.9 7.6 72 0 72 165 1.3 0.1 1.6 0.9 01/18/2007 09:00:00 5.7 0.7 7.6 4.2 9.1 1.2 12.6 6.5 8.5 1.2 11.8 5.7 72 0 72 165 1.3 0 1.6 1.1 01/18/2007 09:10:00 5.7 0.9 7.2 3.4 9 1.3 11.8 5.7 7.7 1.3 11.5 4.6 72 0 72 165 1.1 0 1.4 0.9 01/18/2007 09:20:00 6.2 0.6 7.2 4.2 9.8 1.2 12.6 6.1 8.5 1.1 11.5 5.3 72 0 72 165 1.1 0 1.4 0.9 01/18/2007 09:30:00 6.1 0.7 7.6 4.2 9.7 1.3 13.7 6.1 8.7 1.3 12.6 5.3 72 0 72 165 1 0 1.4 0.9 01/18/2007 09:40:00 6.4 0.6 7.6 4.9 10.5 1.3 14.9 7.2 9.5 1.1 12.2 6.5 72 0 72 165 1.1 0 1.4 0.9 01/18/2007 09:50:00 6.9 0.5 8 5.3 11.5 1.2 14.5 8 9.9 1.3 13.3 6.5 71 0 72 165 1.1 0 1.4 0.9 01/18/2007 10:00:00 7.5 0.3 8.4 6.5 14 1.2 17.9 10.7 11.8 1.4 15.6 8 71 0 71 165 0.8 0.1 1.4 0.7 01/18/2007 10:10:00 7.8 0.2 8.4 7.2 15.8 1 19.1 13.3 13.6 1.2 16.8 10.3 348 56 302 165 0.8 0 1.1 0.9 01/18/2007 10:20:00 7.9 0.2 8.4 7.6 17.2 1 20.6 14.5 14.7 1 19.1 11.8 310 2 310 165 0.8 0 1.1 0.9 01/18/2007 10:30:00 7.9 0.2 8.4 7.2 17.5 1.2 19.9 13.7 15.2 1.3 17.9 12.2 308 2 303 165 0.8 0 1.1 0.9 01/18/2007 10:40:00 8 0.2 8.4 7.6 18.7 1.5 21.8 14.5 16.4 1.6 21 11.8 309 3 309 165 0.9 0 1.1 0.9 01/18/2007 10:50:00 7.8 0.3 8.4 6.8 16.8 1.7 20.2 11.8 15.3 1.7 18.7 11.5 315 7 305 165 0.9 0 1.1 0.9 01/18/2007 11:00:00 7.3 0.3 8.4 6.1 13.6 1.2 18.7 10.3 12.5 1.3 16.1 8.8 321 8 302 165 0.8 0 1.1 0.7 01/18/2007 11:10:00 7.6 0.3 8.4 6.8 15.1 1.5 21 11.1 13.9 1.5 18.3 9.9 326 12 316 165 0.7 0 0.9 0.4 01/18/2007 11:20:00 7.8 0.3 8.4 6.8 16.2 2 22.1 10.7 15.8 2.2 21.8 10.7 335 10 329 165 0.7 0 0.9 0.4 01/18/2007 11:30:00 7.8 0.3 8.4 6.8 16.5 2.4 23.7 9.9 15.9 2.4 22.9 9.9 331 12 323 165 0.8 0 0.9 0.7 01/18/2007 11:40:00 7.8 0.3 8.4 6.5 16.7 2.2 23.7 11.5 16 2 21.8 11.1 333 10 340 165 0.8 0 1.1 0.9 01/18/2007 11:50:00 7.7 0.3 8.4 6.8 16 2.1 21 11.1 15.4 2.2 22.1 10.7 328 10 341 165 0.9 0 1.1 0.9 01/18/2007 12:00:00 7.6 0.3 8.4 6.5 15.3 1.7 20.2 10.3 14.5 1.6 18.3 9.9 329 11 308 165 0.9 0 1.1 0.9 01/18/2007 12:10:00 7.6 0.4 8.4 5.7 15.4 2.1 21.8 9.5 14.9 2.2 21 9.9 335 8 347 165 1 0 1.1 0.9 01/18/2007 12:20:00 7.5 0.4 8.4 5.7 14.7 2.4 22.6 8.8 14 2.2 20.6 8.8 336 8 343 165 1 0 1.4 0.9 01/18/2007 12:30:00 7.5 0.4 8.4 6.1 14.7 2.1 20.6 9.1 14.4 2.2 19.9 7.6 336 9 319 165 1 0 1.4 0.9 01/18/2007 12:40:00 7.3 0.5 8.4 5.7 13.5 2 19.5 8.8 12.8 2 19.5 8.4 323 13 332 165 1.1 0 1.4 0.9 01/18/2007 12:50:00 7.6 0.3 8.4 6.8 14.8 1.5 20.2 11.8 13.3 1.5 18.3 9.9 311 8 302 165 0.8 0 1.1 0.7 01/18/2007 13:00:00 8 0.2 8.4 7.2 17.5 1.5 22.1 13.7 15.3 1.9 22.6 11.5 308 7 302 165 0.4 0 0.7 0.2 01/18/2007 13:10:00 8.1 0.2 8.4 7.6 18.4 1.1 21 14.9 15.8 1.2 19.1 12.2 306 3 305 165 0.3 0 0.7 0.2 01/18/2007 13:20:00 8.1 0.2 8.4 7.6 18.6 1.1 21.4 15.6 16.6 1.5 20.2 12.2 308 4 302 165 0.3 0 0.7 0.2 01/18/2007 13:30:00 8.1 0.2 8.4 7.6 19.4 1.4 25.2 16.1 17.4 1.7 23.3 13.3 308 5 308 165 0.4 0 0.7 0.2 01/18/2007 13:40:00 8.2 0.2 8.8 7.6 20.1 1.5 24.4 15.6 17.4 1.8 22.9 12.6 306 5 305 165 0.5 0 0.7 0.2 01/18/2007 13:50:00 8.2 0.2 8.4 7.6 19.8 1.5 22.9 16.1 17.3 1.3 21 13 307 4 308 165 0.4 0.1 0.7 0.2 01/18/2007 14:00:00 8.2 0.2 8.4 7.6 20.1 1.2 22.9 16.4 17.6 1.3 21.4 13.7 307 3 305 165 0.3 0 0.7 0.2 01/18/2007 14:10:00 8.3 0.2 8.8 8 21.1 1.1 23.7 17.9 18.3 1.3 21.4 14.5 306 4 305 165 0.2 0 0.4 0.2 01/18/2007 14:20:00 8.3 0.2 8.8 8 20.9 1.2 24 16.8 18.2 1.4 21.4 14.5 306 5 304 165 0.2 0 0.4 -0.1 01/18/2007 14:30:00 8.3 0.2 8.4 8 21 1.2 23.7 16.8 18 1.4 21.4 13.7 305 4 303 165 0.1 0 0.2 -0.1 01/18/2007 14:40:00 8.3 0.2 8.8 8 20.2 1.3 23.3 16.8 18.3 1.5 22.9 13 308 5 304 165 0.1 0 0.2 -0.1 01/18/2007 14:50:00 8.2 0.2 8.4 8 19.9 1.3 22.6 16.8 18.9 1.4 21.8 14.1 311 5 301 165 -0.1 0 0.2 -0.1 01/18/2007 15:00:00 8.3 0.2 8.8 8 20.3 1.4 24.8 16.8 19.7 1.5 23.3 14.9 313 5 315 165 -0.1 0 0.2 -0.3 01/18/2007 15:10:00 8.3 0.2 8.8 8 20.9 1.2 25.2 17.9 20.4 1.4 24.8 15.6 315 5 322 165 -0.2 0 0.2 -0.3 01/18/2007 15:20:00 8.2 0.2 8.8 7.6 19.7 1.9 23.7 12.2 19 2 26 13.7 318 9 318 165 -0.1 0 0.2 -0.3 01/18/2007 15:30:00 8.1 0.2 8.4 7.6 18.4 1.6 22.6 14.5 17.2 1.8 22.1 12.6 312 8 334 165 -0.1 0 0.2 -0.3 01/18/2007 15:40:00 8.1 0.2 8.4 7.6 17.3 1.5 22.9 14.1 16.6 1.6 21.4 11.8 313 6 316 165 -0.2 0 0.2 -0.3 01/18/2007 15:50:00 8 0.2 8.4 7.6 16.7 1.4 20.6 13.3 16.3 1.5 22.1 12.6 317 8 318 165 0.1 0 0.2 -0.1 01/18/2007 16:00:00 8 0.3 8.8 7.2 16.2 1.7 24.8 12.6 15.5 1.8 21.8 11.1 314 8 321 165 0.2 0.1 0.7 0.2 01/18/2007 16:10:00 8.1 0.2 8.8 7.6 16.7 1.3 21 13.7 15 1.7 19.1 10.3 309 7 303 165 0.2 0 0.7 0.2 01/18/2007 16:20:00 8 0.3 8.8 6.8 16.5 1.7 25.2 11.8 14.5 2.2 21.4 10.7 308 9 293 165 0.1 0 0.2 -0.1 01/18/2007 16:30:00 8 0.2 8.8 7.2 16.4 1.6 22.9 12.2 15.1 1.9 22.9 9.9 311 7 313 165 0.1 0 0.2 -0.1 01/18/2007 16:40:00 7.9 0.3 8.4 6.8 15.3 1.5 20.2 11.1 13.9 1.7 17.9 9.1 310 6 310 165 0.1 0 0.2 -0.1 01/18/2007 16:50:00 7.7 0.3 8.4 6.8 14.2 1.2 18.7 11.5 13.1 1.7 19.1 9.5 310 6 310 165 0 0 0.2 -0.1 01/18/2007 17:00:00 7.6 0.3 8.4 6.8 13.6 1.1 16.8 11.1 12.8 1.2 15.6 9.5 312 6 319 165 0.1 0.1 0.4 -0.1 01/18/2007 17:10:00 7.6 0.3 8.4 6.5 13.3 1.1 17.9 10.7 11.9 1.7 16.4 8 310 7 310 165 0.1 0 0.2 -0.1 01/18/2007 17:20:00 7.5 0.3 8 6.5 13 0.9 15.3 10.3 10.9 1.2 14.9 7.6 306 5 304 165 0.1 0 0.2 -0.1 01/18/2007 17:30:00 7.4 0.3 8.4 6.8 12.6 0.9 16.4 10.3 11.4 1.1 16.1 8.8 308 4 309 165 0.1 0 0.2 -0.1 01/18/2007 17:40:00 6.7 0.4 7.6 5.7 10.7 0.7 12.6 8.8 8.9 1.3 12.6 5.7 305 5 305 165 0.1 0 0.2 -0.1 01/18/2007 17:50:00 6.6 0.4 7.2 5.3 10.5 0.7 12.2 8 8.8 1.1 12.2 5.7 304 6 298 165 0.1 0 0.2 -0.1 01/18/2007 18:00:00 5.8 0.5 6.8 4.6 9.2 0.7 11.1 7.2 7.3 1 10.3 4.9 299 6 304 165 0 0 0.2 -0.1 01/18/2007 18:10:00 5.4 0.4 6.5 4.6 8.6 0.6 10.7 6.8 6.7 0.9 9.1 4.6 296 6 292 165 -0.1 0 0.2 -0.1 01/18/2007 18:20:00 6.5 0.4 7.2 5.7 10.4 0.7 12.2 8.4 7.6 0.8 9.9 5.3 298 5 294 165 0.1 0 0.2 -0.1 01/18/2007 18:30:00 6.2 0.5 7.2 4.9 9.9 0.8 11.8 8 7.5 1 11.1 5.7 296 6 306 165 0.1 0 0.2 -0.1 01/18/2007 18:40:00 6.3 0.4 6.8 5.3 10.1 0.6 11.5 8.4 7.3 0.8 9.5 5.3 296 4 296 165 0.2 0 0.2 0.2 01/18/2007 18:50:00 5.5 0.5 6.8 4.2 8.8 0.7 10.7 6.8 6.7 1.1 9.5 4.6 293 5 295 165 0.2 0 0.4 -0.1 01/18/2007 19:00:00 5 0.4 5.7 3.8 8.2 0.6 9.5 6.8 7.8 0.9 9.9 4.6 284 5 285 165 0.3 0 0.7 0.2 01/18/2007 19:10:00 5.1 0.4 6.1 3.8 8.4 0.6 9.5 6.5 7.2 1 9.5 4.6 289 4 292 165 0.5 0 0.9 0.2 01/18/2007 19:20:00 4.6 0.5 5.7 3.4 7.6 0.7 9.1 5.7 7 1.1 9.5 4.6 286 5 278 165 0.6 0 0.9 0.4 01/18/2007 19:30:00 4.4 0.3 5.3 3.8 7.3 0.4 8.4 6.1 7.1 0.6 8.8 4.2 283 5 285 165 0.6 0 0.9 0.2 01/18/2007 19:40:00 4.9 0.3 5.7 3.8 8 0.4 9.1 6.8 7.9 0.5 8.8 6.5 280 3 281 165 0.7 0 0.9 0.7 01/18/2007 19:50:00 5.1 0.3 5.7 4.2 8.3 0.5 9.5 6.1 7.5 0.9 9.1 4.9 286 4 281 165 0.8 0 0.9 0.7 01/18/2007 20:00:00 5.3 0.5 6.5 3.8 8.5 0.7 9.9 6.1 7.8 1 10.3 4.9 286 5 285 165 0.9 0 1.1 0.7 01/18/2007 20:10:00 5.1 0.5 6.5 3.8 8.2 0.7 9.9 6.5 8.2 0.8 10.3 5.7 281 5 275 165 0.9 0 1.1 0.9 01/18/2007 20:20:00 4.7 0.4 5.7 3.8 7.7 0.5 9.1 6.5 7.3 0.7 9.5 4.6 285 4 278 165 0.9 0 1.1 0.7 01/18/2007 20:30:00 5 0.3 6.1 4.2 8.1 0.4 9.5 7.2 6.5 1 8.8 4.6 291 3 289 165 1 0 1.1 0.9 01/18/2007 20:40:00 4.5 0.4 5.3 3.4 7.4 0.6 9.1 6.1 6.3 1.1 8.8 3.8 289 4 287 165 0.9 0 1.1 0.9 01/18/2007 20:50:00 3.9 0.7 5.3 2.6 6.4 0.9 8.8 4.6 5.6 1.1 8.4 3.4 290 6 285 165 0.9 0 1.1 0.9 01/18/2007 21:00:00 3.8 0.6 5.3 2.3 6.5 0.8 8.4 4.2 6.4 0.9 8.8 3.8 279 6 279 165 1.1 0 1.4 0.9 01/18/2007 21:10:00 3.3 0.5 4.9 1.9 5.8 0.7 7.6 4.2 5.1 1 7.2 2.6 285 7 284 165 1.1 0 1.4 0.9 01/18/2007 21:20:00 2.7 0.4 3.8 1.9 5.1 0.5 6.5 3.8 4.1 0.7 6.5 2.6 297 8 287 165 1 0 1.4 0.9 01/18/2007 21:30:00 0.7 0.7 3 0.4 4 0.6 5.7 1.9 3.6 0.6 5.7 2.3 308 13 315 165 0.9 0 1.1 0.9 01/18/2007 21:40:00 0.4 0 0.4 0.4 3.2 1 4.9 0.4 3.2 0.8 4.9 0.7 317 17 165 165 0.9 0 1.1 0.9 01/18/2007 21:50:00 0.4 0 0.4 0.4 2 0.4 3.4 0.7 1.8 0.5 3 0.7 303 11 165 165 1 0 1.4 0.9 01/18/2007 22:00:00 0.4 0 0.4 0.4 2.6 0.5 3.8 0.7 2.2 0.5 3.4 1.1 300 7 165 165 1 0 1.4 0.9 01/18/2007 22:10:00 0.4 0 0.4 0.4 2.8 0.3 3.4 2.3 2.5 0.3 3 1.5 301 4 165 165 1 0 1.4 0.9 01/18/2007 22:20:00 0.4 0 0.4 0.4 3.3 0.5 4.2 2.3 2.9 0.7 4.9 1.5 289 6 165 165 1 0 1.4 0.9 01/18/2007 22:30:00 0.4 0 0.4 0.4 3.1 0.3 3.8 2.3 2.3 0.4 3.4 1.5 296 4 165 165 1.1 0 1.4 0.9 01/18/2007 22:40:00 0.4 0 0.4 0.4 2 0.5 3 0.4 2 0.4 3 1.1 283 11 165 165 1.2 0.1 1.6 0.9 01/18/2007 22:50:00 0.4 0 0.4 0.4 0.5 0.3 2.3 0.4 0.8 0.5 1.9 0.4 176 53 165 165 0.8 0.3 1.6 0.2 01/18/2007 23:00:00 0.4 0 0.4 0.4 0.4 0.1 0.7 0.4 0.9 0.3 1.5 0.4 157 14 165 165 0.5 0.1 0.9 0.2 01/18/2007 23:10:00 0.4 0 0.4 0.4 0.6 0.3 1.5 0.4 1.2 0.4 2.3 0.4 184 13 165 165 0.8 0 0.9 0.7 01/18/2007 23:20:00 0.4 0 0.4 0.4 0.6 0.4 1.5 0.4 1.5 0.3 2.3 1.1 217 9 165 165 0.9 0 1.4 0.9 01/18/2007 23:30:00 0.4 0 0.4 0.4 0.4 0.1 1.1 0.4 0.7 0.4 1.5 0.4 231 5 165 165 1.2 0 1.4 0.9 01/18/2007 23:40:00 0.4 0 0.4 0.4 0.5 0.3 1.1 0.4 1.3 0.5 2.3 0.4 194 9 165 165 0.9 0 1.1 0.9 01/18/2007 23:50:00 0.4 0 0.4 0.4 0.7 0.2 1.1 0.4 1.7 0.2 2.3 1.1 176 2 165 165 0.7 0 0.9 0.7 01/19/2007 00:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 1.3 0.3 1.9 0.4 164 2 165 165 0.7 0 0.9 0.7 01/19/2007 00:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 1 0.3 1.5 0.4 165 3 165 165 0.8 0 0.9 0.7 01/19/2007 00:20:00 0.4 0 0.4 0.4 0.4 0.1 1.1 0.4 0.5 0.3 1.5 0.4 222 12 165 165 0.9 0 1.1 0.7 01/19/2007 00:30:00 0.4 0 0.4 0.4 0.8 0.6 2.3 0.4 1.3 0.9 3 0.4 190 41 165 165 0.6 0 0.9 0.2 01/19/2007 00:40:00 0.4 0 0.4 0.4 1.3 0.7 2.6 0.4 2 0.6 3 0.7 154 8 165 165 0.3 0 0.7 0.2 01/19/2007 00:50:00 0.4 0 0.4 0.4 1.5 0.5 2.6 0.4 2.3 0.4 3 1.5 166 14 165 165 0.4 0 0.7 0.2 01/19/2007 01:00:00 0.4 0 0.4 0.4 2 0.4 2.6 1.1 2.6 0.3 3.4 1.9 191 10 165 165 0.7 0.1 0.9 0.7 01/19/2007 01:10:00 0.4 0 0.4 0.4 1.2 0.5 2.3 0.4 1.9 0.4 2.6 0.7 211 2 165 165 0.9 0 1.1 0.9 01/19/2007 01:20:00 0.4 0 0.4 0.4 1.4 0.3 2.3 0.7 2.2 0.3 3 1.5 221 3 165 165 0.9 0 1.4 0.9 01/19/2007 01:30:00 0.4 0 0.4 0.4 1 0.3 1.5 0.4 1.7 0.3 2.3 1.1 240 11 165 165 1.2 0.2 1.6 0.9 01/19/2007 01:40:00 0.4 0 0.4 0.4 0.4 0.2 1.5 0.4 1 0.4 1.9 0.4 266 15 165 165 1.1 0.2 1.6 0.7 01/19/2007 01:50:00 0.4 0 0.4 0.4 1.1 0.8 2.6 0.4 1.7 1 3 0.4 170 51 165 165 0.2 0.3 0.9 -0.1 01/19/2007 02:00:00 0.4 0 0.4 0.4 0.8 0.5 1.9 0.4 1.7 0.4 3 0.7 156 9 165 165 0.1 0.1 0.2 -0.3 01/19/2007 02:10:00 0.4 0 0.4 0.4 1.1 0.5 2.3 0.4 1.8 0.5 3 0.7 174 13 165 165 0.1 0 0.2 -0.1 01/19/2007 02:20:00 0.4 0 0.4 0.4 1.4 0.4 2.3 0.4 2.1 0.6 2.6 0.4 205 7 165 165 0.1 0 0.2 -0.1 01/19/2007 02:30:00 0.6 0.4 1.9 0.4 2.5 0.5 3.4 1.1 3 0.4 4.2 1.9 201 6 199 165 0.1 0 0.2 -0.1 01/19/2007 02:40:00 1.7 0.5 2.6 0.4 3.6 0.4 4.6 2.3 3.9 0.4 4.6 3 208 3 204 165 0.2 0.1 0.4 -0.1 01/19/2007 02:50:00 1 0.6 2.3 0.4 3 0.5 4.2 1.9 3.4 0.4 4.6 2.6 207 5 205 165 0.2 0 0.7 -0.1 01/19/2007 03:00:00 0.9 0.6 1.9 0.4 2.9 0.5 3.8 1.9 3.3 0.4 4.2 2.3 214 16 192 165 0.2 0.2 0.9 -0.1 01/19/2007 03:10:00 1.9 0.3 2.6 1.1 3.7 0.3 4.2 3 4 0.3 4.6 3 224 5 224 165 0.7 0 0.9 0.2 01/19/2007 03:20:00 0.8 0.6 2.3 0.4 2.6 0.8 4.2 0.7 3 0.7 4.6 1.1 217 19 233 165 0.2 0.3 1.1 -0.3 01/19/2007 03:30:00 0.4 0 0.4 0.4 3 0.3 3.8 2.3 3.4 0.3 4.2 2.3 220 5 165 165 0.5 0.3 1.1 0.2 01/19/2007 03:40:00 1.2 0.8 2.6 0.4 3.3 0.4 4.2 2.3 3.7 0.3 4.6 3.4 218 4 229 165 0.4 0 0.7 0.2 01/19/2007 03:50:00 1.9 0.5 3 0.7 3.4 0.5 4.9 2.3 3.8 0.4 4.9 2.6 209 6 213 165 0.4 0.1 0.7 0.2 01/19/2007 04:00:00 1.3 1 3 0.4 2.8 1 4.6 0.7 3.4 0.9 4.9 1.5 229 14 212 165 0.3 0 0.7 0.2 01/19/2007 04:10:00 0.4 0 0.4 0.4 1.6 0.5 2.3 0.4 2.4 0.3 3 1.5 218 6 165 165 0.3 0 0.7 0.2 01/19/2007 04:20:00 0.4 0 0.4 0.4 2 0.6 2.6 0.4 2.8 0.4 3.4 1.9 219 7 165 165 0.2 0.1 0.7 -0.1 01/19/2007 04:30:00 1.1 0.7 2.3 0.4 2.7 0.6 4.2 1.5 3.2 0.5 4.6 0.7 202 9 210 165 0.1 0.1 0.7 -0.1 01/19/2007 04:40:00 0.5 0.4 1.5 0.4 2 0.6 3.4 0.4 2.5 0.6 3.8 1.1 198 8 202 165 0.1 0 0.2 -0.1 01/19/2007 04:50:00 1.1 0.4 1.9 0.4 2.6 0.3 3.4 1.9 2.8 0.3 3.4 1.9 208 2 206 165 0.1 0 0.2 -0.1 01/19/2007 05:00:00 1.4 0.4 2.3 0.4 2.8 0.4 3.8 1.9 3 0.4 3.8 2.3 206 3 209 165 0 0 0.2 -0.1 01/19/2007 05:10:00 2.1 0.4 3 0.7 3.6 0.5 4.6 2.3 3.7 0.5 4.9 1.9 211 4 206 165 0.2 0 0.4 -0.1 01/19/2007 05:20:00 2.7 0.6 3.8 1.1 4.2 0.7 5.3 3 4.5 0.7 6.1 2.6 206 2 209 165 0 0 0.2 -0.1 01/19/2007 05:30:00 2.6 0.4 3.4 0.4 4 0.5 4.9 1.5 4.2 0.5 5.3 1.9 205 5 200 165 0.1 0 0.2 -0.1 01/19/2007 05:40:00 2.2 0.6 3.4 0.4 3.6 0.8 4.9 1.5 3.8 0.6 5.3 2.6 199 8 204 165 -0.1 0.1 0.2 -0.5 01/19/2007 05:50:00 2.4 0.6 3.4 0.7 3.8 0.6 5.3 2.3 3.7 0.5 4.9 2.3 200 6 192 165 -0.4 0 -0.3 -0.5 01/19/2007 06:00:00 2.8 0.6 3.8 1.1 4.4 0.6 5.7 2.6 4.2 0.6 5.7 2.6 213 6 215 165 -0.2 0 0.2 -0.5 01/19/2007 06:10:00 2.3 0.7 3.4 0.4 3.9 0.7 4.9 1.9 3.9 0.6 5.3 2.3 216 8 230 165 0 0 0.2 -0.3 01/19/2007 06:20:00 1.7 0.4 2.6 0.4 3.2 0.4 4.2 1.9 3.3 0.3 4.2 2.6 210 7 218 165 -0.2 0 -0.1 -0.3 01/19/2007 06:30:00 2.7 0.5 4.2 1.9 4.2 0.5 5.7 3 4.2 0.5 5.7 2.6 204 5 201 165 -0.2 0 -0.1 -0.3 01/19/2007 06:40:00 1.9 0.8 4.2 0.4 3.3 0.8 5.7 1.1 3 0.8 5.3 1.1 200 12 215 165 -0.2 0.1 -0.1 -0.5 01/19/2007 06:50:00 3.2 0.4 4.2 1.9 4.7 0.4 5.7 3 4.6 0.6 5.7 2.3 208 5 214 165 -0.1 0.1 0.2 -0.5 01/19/2007 07:00:00 4.7 1 6.1 2.6 5.4 0.4 6.1 4.2 5.6 0.4 6.5 4.6 198 2 200 165 -0.2 0.1 0.2 -0.3 01/19/2007 07:10:00 4.9 0.3 5.3 4.2 4.9 0.4 5.7 4.2 5.4 0.4 6.1 4.6 196 4 201 165 -0.3 0 -0.1 -0.5 01/19/2007 07:20:00 4.5 0.3 5.3 3.8 4.5 0.3 5.3 3.8 4.8 0.3 5.3 4.2 191 5 189 165 -0.3 0 -0.3 -0.5 01/19/2007 07:30:00 3.5 0.5 4.6 2.3 3.5 0.5 4.6 2.3 3.7 0.5 4.9 2.6 193 7 195 165 -0.4 0 -0.3 -0.5 01/19/2007 07:40:00 3.1 0.5 4.2 1.5 3 0.5 4.2 1.1 3.1 0.6 4.2 1.5 190 8 190 165 -0.3 0 -0.1 -0.5 01/19/2007 07:50:00 2.9 0.9 6.5 0.4 2.9 0.9 6.5 0.4 2.8 0.7 4.6 1.1 203 14 208 165 -0.3 0 -0.1 -0.5 01/19/2007 08:00:00 3.3 0.7 4.9 1.9 3.4 0.7 4.9 2.3 3.2 0.7 5.3 1.5 215 8 206 165 -0.3 0 -0.1 -0.5 01/19/2007 08:10:00 3.3 0.7 4.9 1.9 3.3 0.7 4.9 1.9 3.5 0.6 5.3 1.9 200 9 196 165 -0.3 0 -0.1 -0.5 01/19/2007 08:20:00 5 0.7 6.5 3.4 5.1 0.7 6.5 3.4 5.3 0.7 7.2 3.4 192 6 196 165 -0.3 0 -0.3 -0.5 01/19/2007 08:30:00 5.9 0.8 8.4 3.8 6 0.8 8.8 3.8 6 0.8 8.4 4.2 190 7 205 165 -0.1 0.2 0.4 -0.3 01/19/2007 08:40:00 4.8 0.5 6.1 3.4 4.8 0.5 6.1 3.4 5.1 0.5 6.5 3.8 190 6 187 165 0.2 0 0.7 -0.1 01/19/2007 08:50:00 3.9 0.4 4.9 3 3.8 0.4 4.9 2.6 4.2 0.4 5.3 3 188 6 185 165 0.2 0 0.7 -0.1 01/19/2007 09:00:00 4.3 0.3 5.3 3.4 4.1 0.3 4.9 3.4 4.5 0.4 5.3 3.4 183 5 181 165 -0.1 0 0.2 -0.3 01/19/2007 09:10:00 3.9 0.7 5.7 2.3 3.8 0.7 5.7 2.3 4.1 0.7 5.7 2.6 191 9 196 165 -0.1 0.1 0.2 -0.3 01/19/2007 09:20:00 4.4 0.7 6.1 2.6 4.3 0.7 6.1 3 4.4 0.7 6.1 3 179 8 182 165 -0.2 0 -0.1 -0.3 01/19/2007 09:30:00 5.1 0.6 6.5 4.2 5 0.6 6.5 3.8 4.9 0.6 6.5 3.8 174 10 180 165 -0.2 0.1 -0.1 -0.5 01/19/2007 09:40:00 4.5 0.5 5.7 3 4.3 0.5 5.7 3 4.5 0.6 6.1 3.4 172 9 165 165 -0.2 0 -0.1 -0.3 01/19/2007 09:50:00 2.5 0.7 4.2 1.1 2.5 0.7 4.2 1.1 2.8 0.7 4.6 1.1 174 5 166 165 -0.2 0 -0.1 -0.3 01/19/2007 10:00:00 2.2 0.5 3.4 1.1 2.2 0.5 3.4 1.1 2.5 0.4 3.4 1.5 168 10 167 165 0.1 0.1 0.4 -0.3 01/19/2007 10:10:00 3.8 0.5 5.3 2.6 3.7 0.5 5.3 2.6 3.8 0.4 4.9 3 172 13 188 165 0.3 0.1 0.7 -0.1 01/19/2007 10:20:00 5 0.6 6.5 3.4 5.1 0.6 6.5 3.8 5.1 0.7 7.2 3.4 196 5 197 165 1 0.2 1.4 0.7 01/19/2007 10:30:00 3.9 0.6 6.1 2.3 3.7 0.6 6.1 1.9 3.8 0.6 6.1 2.3 202 9 189 165 1.4 0 1.6 1.1 01/19/2007 10:40:00 3.8 0.6 4.9 2.3 3.7 0.6 4.6 1.9 3.7 0.6 4.9 2.3 205 7 208 165 1.5 0 1.8 1.4 01/19/2007 10:50:00 4.2 0.7 6.1 2.6 4 0.7 6.1 2.6 4.3 0.7 6.1 3 195 6 204 165 1.6 0 1.8 0.9 01/19/2007 11:00:00 4.5 0.9 6.5 2.3 4.4 0.9 6.1 1.9 4.5 0.8 6.5 2.6 200 6 196 165 1.6 0 1.8 1.1 01/19/2007 11:10:00 5.5 0.8 8.8 3.4 5.4 0.8 8 3.4 5.4 0.9 8.4 3.4 204 6 205 165 1.5 0 1.6 1.1 01/19/2007 11:20:00 4.7 0.5 6.1 3.4 4.5 0.5 5.7 3 4.7 0.5 5.7 3.4 202 6 194 165 1.3 0 1.6 1.1 01/19/2007 11:30:00 5.7 0.6 7.6 4.6 5.5 0.6 7.2 4.2 5.8 0.6 7.6 4.2 201 4 202 165 1.5 0 1.8 1.1 01/19/2007 11:40:00 4.7 0.8 7.2 3 4.6 0.8 6.8 2.6 4.8 0.8 6.8 2.6 204 9 206 165 2 0.2 2.6 1.6 01/19/2007 11:50:00 3.8 0.7 5.3 1.9 3.6 0.7 5.3 1.9 3.9 0.6 5.7 2.3 192 11 207 165 2.1 0.2 2.6 1.4 01/19/2007 12:00:00 3.9 1 6.8 1.9 3.8 1 6.8 2.3 3.8 1 6.8 1.5 197 12 197 165 1.9 0 2.3 1.6 01/19/2007 12:10:00 5.2 0.7 7.2 3.4 5.1 0.7 7.2 3 5.2 0.7 7.2 3.4 208 6 212 165 1.7 0.1 1.8 0.9 01/19/2007 12:20:00 4.4 0.7 6.8 2.6 4.3 0.7 6.8 2.6 4.6 0.6 6.8 3 208 10 206 165 1.9 0.2 2.6 1.6 01/19/2007 12:30:00 4.5 0.6 6.8 3 4.4 0.6 6.8 3 4.7 0.6 7.2 3 209 9 221 165 2.6 0.2 3 1.8 01/19/2007 12:40:00 4.9 0.6 6.5 3 4.8 0.6 6.1 3 4.9 0.6 6.5 2.6 202 10 183 165 2.6 0.2 3 2.3 01/19/2007 12:50:00 4 0.8 5.7 1.9 3.9 0.8 5.7 1.1 4 0.8 6.1 1.9 202 11 214 165 2.9 0.1 3.3 2.6 01/19/2007 13:00:00 2.7 0.7 4.6 0.7 2.5 0.8 4.6 0.4 2.8 0.7 4.6 1.1 214 12 216 165 3.2 0.1 3.8 3 01/19/2007 13:10:00 3.5 1 5.3 1.5 3.4 1 5.3 1.1 3.6 1 5.7 1.5 227 11 237 165 3.2 0.2 3.8 2.8 01/19/2007 13:20:00 3.2 0.9 5.7 0.7 2.9 0.9 5.7 0.4 3.3 0.8 5.3 1.5 228 11 239 165 2.7 0.2 3 2.3 01/19/2007 13:30:00 3.8 0.7 5.7 2.3 3.6 0.8 5.7 1.9 3.8 0.7 5.3 1.9 225 9 229 165 2.9 0 3.3 2.8 01/19/2007 13:40:00 3.1 0.8 5.3 1.5 2.9 0.8 4.9 0.7 3.2 0.7 4.9 1.5 216 18 226 165 2.9 0.1 3.3 2.8 01/19/2007 13:50:00 3 0.8 5.3 1.9 2.7 0.8 5.3 1.5 3 0.7 5.3 1.5 202 17 222 165 2.6 0.4 3.5 1.8 01/19/2007 14:00:00 2.7 0.6 4.2 0.7 2.2 0.8 3.8 0.4 2.6 0.7 4.2 0.7 196 19 192 165 1.7 0 1.8 1.4 01/19/2007 14:10:00 2.3 0.6 3.8 0.7 1.7 0.8 3.4 0.4 2.4 0.6 3.8 0.7 185 15 207 165 1.6 0 1.8 1.1 01/19/2007 14:20:00 0.9 0.6 2.3 0.4 0.5 0.4 1.9 0.4 1 0.7 2.3 0.4 185 3 178 165 1.9 0.1 2.3 1.6 01/19/2007 14:30:00 0.6 0.4 1.9 0.4 0.4 0.2 1.5 0.4 0.5 0.2 1.1 0.4 196 13 210 165 2.4 0.2 3 2.1 01/19/2007 14:40:00 1 0.7 3 0.4 0.8 0.7 3 0.4 1 0.8 3 0.4 217 20 206 165 3.5 0.2 4.3 2.8 01/19/2007 14:50:00 2.4 0.6 4.2 1.1 2.2 0.6 3.8 1.1 2.5 0.6 4.2 1.5 191 20 177 165 2.7 0.3 3.5 1.8 01/19/2007 15:00:00 4.1 0.7 6.1 2.6 3.7 0.6 5.7 2.3 4.3 0.5 5.3 2.6 171 7 179 165 1.7 0.1 2.3 1.4 01/19/2007 15:10:00 3.7 0.6 5.7 2.6 3.2 0.6 5.3 2.3 3.6 0.5 4.9 2.3 180 9 178 165 1.4 0.1 1.6 0.9 01/19/2007 15:20:00 4.4 0.8 6.1 2.6 4 0.8 5.7 2.3 4.5 0.7 6.1 3 180 11 179 165 1.5 0.1 1.8 0.9 01/19/2007 15:30:00 4.6 0.8 6.1 2.6 4.3 0.8 5.7 2.3 4.6 0.7 6.1 3 176 9 181 165 1.5 0.1 1.8 0.9 01/19/2007 15:40:00 4.6 0.6 5.7 3 4.3 0.5 5.3 3 4.7 0.6 5.7 3.4 176 13 170 165 1.3 0 1.6 1.1 01/19/2007 15:50:00 4.2 0.7 6.1 3 4 0.7 5.7 3 4.3 0.7 6.1 3.4 178 8 181 165 1.2 0.1 1.6 0.9 01/19/2007 16:00:00 4.9 0.6 6.5 3.8 4.7 0.5 6.1 3.4 4.9 0.5 6.1 3.4 179 13 192 165 1.1 0 1.4 0.9 01/19/2007 16:10:00 4.9 0.6 6.5 3.8 4.7 0.6 6.5 3.8 5 0.6 7.2 4.2 171 15 188 165 1.2 0.2 1.6 0.7 01/19/2007 16:20:00 5.3 0.9 7.6 3.8 5.1 0.9 7.2 3.4 5.4 0.9 7.6 3.8 181 10 179 165 1.1 0.2 1.4 0.7 01/19/2007 16:30:00 4.8 0.5 6.1 3.4 4.7 0.5 5.7 3.4 4.9 0.5 6.1 3.4 188 6 187 165 1 0 1.4 0.4 01/19/2007 16:40:00 4.2 0.5 6.5 3 4 0.5 6.1 3 4.3 0.4 5.7 3.4 162 16 180 165 1 0 1.4 0.4 01/19/2007 16:50:00 4.7 0.5 6.5 3.4 4.5 0.5 6.1 3.4 4.7 0.5 6.1 3.4 151 17 151 165 0.9 0.1 1.1 0.7 01/19/2007 17:00:00 4.2 0.7 6.1 2.6 4 0.7 6.1 2.3 4.4 0.7 6.1 3 163 16 176 165 0.9 0 1.1 0.7 01/19/2007 17:10:00 3.2 0.5 4.9 2.3 3.1 0.6 4.9 2.3 3.4 0.5 4.9 2.6 156 11 150 165 0.8 0.1 1.1 0.2 01/19/2007 17:20:00 5.5 0.6 6.8 3.8 5.4 0.6 6.5 3.8 5.7 0.6 6.8 4.2 153 17 140 165 0.8 0.1 1.1 0.2 01/19/2007 17:30:00 6.3 0.8 8.4 3.8 6 0.8 8 4.2 6.5 0.8 8.8 4.2 157 24 165 165 0.8 0.2 1.1 0.2 01/19/2007 17:40:00 7 0.5 8 5.3 6.7 0.4 7.6 4.9 7.2 0.5 8.4 5.7 169 10 167 165 0.7 0.2 0.9 0.2 01/19/2007 17:50:00 5.5 1 8 3.4 5.3 1 8 3.4 5.7 1 7.6 3.8 177 7 169 165 0.5 0.2 0.9 -0.3 01/19/2007 18:00:00 5.7 0.7 7.6 3.8 5.4 0.6 7.2 3.8 5.8 0.6 7.2 4.2 177 8 189 165 0.3 0 0.7 0.2 01/19/2007 18:10:00 5.9 0.7 7.6 4.2 5.6 0.7 7.2 3.8 6.1 0.7 8 4.6 167 22 165 165 0.3 0.1 0.7 -0.1 01/19/2007 18:20:00 5.2 0.5 6.5 3.8 5 0.5 6.1 3.8 5.3 0.5 6.5 3.8 152 23 171 165 0.2 0 0.4 -0.1 01/19/2007 18:30:00 4.5 0.7 6.1 3 4.3 0.6 5.7 2.6 4.7 0.5 6.1 3.4 158 15 145 165 0.2 0 0.4 -0.1 01/19/2007 18:40:00 5.6 0.6 6.8 4.2 5.3 0.6 6.5 3.8 5.8 0.6 6.8 4.2 157 27 165 165 0.3 0 0.7 -0.1 01/19/2007 18:50:00 5.8 0.5 7.2 4.6 5.5 0.5 6.8 4.2 5.9 0.5 6.8 4.6 159 26 175 165 0.3 0 0.7 -0.1 01/19/2007 19:00:00 4.7 0.8 6.8 3 4.5 0.8 6.5 3 5 0.8 7.2 3.4 158 18 157 165 0.2 0.1 0.7 -0.1 01/19/2007 19:10:00 4.4 0.6 6.1 3 4.1 0.6 6.1 3 4.6 0.6 6.1 3.4 172 13 172 165 0.2 0.1 0.7 -0.5 01/19/2007 19:20:00 6.1 1 8.4 4.2 5.9 1 8 4.2 6.3 0.8 8 4.6 169 22 185 165 0.2 0 0.4 -0.3 01/19/2007 19:30:00 6.4 0.7 8 4.2 6.1 0.6 7.6 3.8 6.6 0.6 8.4 5.3 161 27 160 165 0.2 0 0.4 -0.1 01/19/2007 19:40:00 6.1 0.8 8 4.6 5.8 0.7 8 4.6 6.2 0.8 8 4.6 157 23 166 165 0.1 0 0.2 -0.1 01/19/2007 19:50:00 5.9 0.4 6.8 4.9 5.6 0.4 6.8 4.6 6 0.4 7.2 4.9 158 24 154 165 0.1 0 0.2 -0.1 01/19/2007 20:00:00 6.4 0.7 8.8 4.6 6.2 0.7 8 4.6 6.7 0.8 8.8 4.6 154 24 169 165 0.1 0 0.2 -0.1 01/19/2007 20:10:00 7.4 1 9.1 4.9 7.1 0.9 8.8 4.6 7.6 1 9.5 4.9 163 22 165 165 0.1 0 0.2 -0.1 01/19/2007 20:20:00 6.6 0.7 8 4.9 6.3 0.7 7.6 4.6 6.7 0.7 8 4.9 176 8 177 165 0.1 0 0.2 -0.1 01/19/2007 20:30:00 6.5 0.4 7.2 5.3 6.1 0.4 6.8 4.9 6.3 0.5 7.6 4.9 174 8 179 165 -0.1 0 0.2 -0.3 01/19/2007 20:40:00 5.9 0.7 7.6 4.2 5.6 0.7 7.2 3.8 6 0.8 7.6 4.6 178 4 181 165 -0.1 0 0.2 -0.3 01/19/2007 20:50:00 3.9 0.8 6.1 2.3 3.6 0.8 5.7 1.9 4 0.8 5.7 1.9 176 8 180 165 -0.2 0.1 -0.1 -0.3 01/19/2007 21:00:00 3 0.5 4.2 1.9 2.7 0.5 3.8 1.1 3.1 0.5 4.2 1.9 183 4 184 165 -0.3 0 -0.1 -0.5 01/19/2007 21:10:00 3.8 0.4 5.3 3 3.4 0.5 4.9 2.6 4 0.4 5.3 3 182 3 191 165 -0.3 0 -0.1 -0.5 01/19/2007 21:20:00 5.3 0.6 6.8 4.2 5 0.5 6.5 3.8 5.4 0.4 6.8 4.6 184 7 172 165 -0.3 0 -0.3 -0.5 01/19/2007 21:30:00 5.9 0.4 6.8 4.9 5.6 0.3 6.5 4.9 6.1 0.3 6.8 4.9 154 29 177 165 -0.4 0 -0.1 -0.8 01/19/2007 21:40:00 6.5 1 9.1 4.2 6.2 1 9.1 4.2 6.5 0.8 9.1 4.6 171 20 175 165 -0.3 0 -0.1 -0.5 01/19/2007 21:50:00 6.3 0.9 9.5 4.6 6.1 0.8 8.8 4.6 6.3 0.9 9.1 4.9 191 7 178 165 -0.1 0 0.2 -0.3 01/19/2007 22:00:00 5.7 0.6 7.2 4.2 5.4 0.6 6.8 3.8 5.8 0.6 7.6 4.6 192 5 197 165 -0.1 0 0.2 -0.3 01/19/2007 22:10:00 5 0.4 5.7 3.8 4.6 0.3 5.3 3.8 5.1 0.4 6.1 4.2 183 5 190 165 -0.2 0 -0.1 -0.3 01/19/2007 22:20:00 5.1 0.7 7.2 3.4 4.8 0.6 6.8 3.4 5.2 0.6 7.2 3.8 159 26 160 165 -0.2 0 -0.1 -0.5 01/19/2007 22:30:00 5.8 0.5 7.2 4.2 5.5 0.5 6.8 3.8 5.9 0.5 7.2 4.9 148 27 140 165 -0.3 0.1 -0.1 -0.8 01/19/2007 22:40:00 6.1 0.6 7.6 4.9 5.7 0.6 7.2 4.6 6.1 0.6 7.6 4.9 164 13 165 165 -0.4 0 -0.3 -0.8 01/19/2007 22:50:00 5.1 0.4 6.1 4.2 4.7 0.4 5.7 4.2 5.2 0.3 6.1 4.6 167 9 176 165 -0.4 0 -0.3 -0.5 01/19/2007 23:00:00 5.3 0.4 6.1 4.6 4.9 0.3 5.7 4.2 5.4 0.4 6.1 4.6 169 17 172 165 -0.3 0 -0.1 -0.5 01/19/2007 23:10:00 5.5 0.4 6.8 4.6 5.2 0.4 6.1 4.2 5.7 0.3 6.5 4.9 158 26 124 165 -0.4 0 -0.1 -0.5 01/19/2007 23:20:00 5.6 0.4 6.8 4.6 5.3 0.4 6.5 4.6 5.8 0.4 6.8 4.9 172 11 173 165 -0.3 0 -0.1 -0.5 01/19/2007 23:30:00 5.8 0.4 7.2 4.6 5.4 0.4 7.2 4.6 5.9 0.4 6.8 4.6 177 5 183 165 -0.3 0 -0.1 -0.5 01/19/2007 23:40:00 6 0.6 7.6 4.2 5.7 0.5 7.2 4.2 6.1 0.6 7.6 4.6 178 7 180 165 -0.3 0.1 -0.1 -0.5 01/19/2007 23:50:00 5.3 0.5 6.8 4.2 5.1 0.5 6.8 4.2 5.5 0.5 7.2 4.6 186 4 180 165 -0.3 0 -0.1 -0.5 01/20/2007 00:00:00 4.6 0.6 6.1 3.4 4.3 0.6 5.7 3 4.7 0.6 6.1 3.8 173 8 181 165 -0.3 0 -0.1 -0.5 01/20/2007 00:10:00 5.4 0.9 7.2 3 5.1 0.8 6.5 2.6 5.5 0.8 7.2 3.4 169 18 172 165 -0.3 0 -0.1 -0.5 01/20/2007 00:20:00 5.9 0.5 7.6 4.6 5.5 0.5 6.8 4.6 5.8 0.5 7.2 4.6 178 4 177 165 -0.4 0 -0.3 -0.5 01/20/2007 00:30:00 6.9 0.4 8 6.1 6.5 0.4 7.6 5.7 7 0.4 8.4 6.1 171 7 106 165 -0.2 0 -0.1 -0.5 01/20/2007 00:40:00 6.8 0.6 8.4 4.9 6.5 0.6 8 4.9 6.9 0.6 8.8 5.3 184 7 193 165 -0.3 0 -0.1 -0.5 01/20/2007 00:50:00 6.4 0.3 7.2 5.7 6 0.3 6.8 5.3 6.5 0.4 7.6 5.3 178 5 185 165 -0.5 0 -0.3 -0.8 01/20/2007 01:00:00 6.7 0.3 7.2 6.1 6.2 0.3 6.8 5.3 6.7 0.2 7.2 6.1 165 12 165 165 -0.5 0.1 -0.3 -0.8 01/20/2007 01:10:00 6.9 0.6 7.6 4.6 6.5 0.6 7.2 4.6 6.8 0.7 8 4.2 169 9 173 165 -0.3 0 -0.1 -0.5 01/20/2007 01:20:00 6.4 0.6 7.2 4.6 6.1 0.5 6.8 4.6 6.3 0.6 7.6 4.6 144 27 148 165 -0.3 0 -0.1 -0.5 01/20/2007 01:30:00 5.9 0.7 7.2 4.2 5.6 0.7 6.8 3.8 6 0.6 7.2 4.6 152 24 161 165 -0.2 0 -0.1 -0.3 01/20/2007 01:40:00 5.4 0.5 6.8 3.8 5.2 0.5 6.5 3.8 5.6 0.5 6.8 4.2 185 6 187 165 -0.2 0 -0.1 -0.3 01/20/2007 01:50:00 4.5 0.5 5.7 3.4 4.2 0.5 5.3 2.6 4.7 0.5 6.1 3.8 180 4 179 165 -0.4 0 -0.3 -0.8 01/20/2007 02:00:00 3 0.5 4.2 1.9 2.7 0.5 3.8 1.5 3.2 0.5 4.6 1.9 163 11 171 165 -0.5 0 -0.3 -0.8 01/20/2007 02:10:00 2.9 0.4 3.8 1.9 2.7 0.4 3.8 1.5 3 0.4 3.8 2.3 155 15 151 165 -0.4 0 -0.3 -0.5 01/20/2007 02:20:00 3.1 0.4 4.2 2.3 2.8 0.4 4.2 1.9 3.2 0.3 4.2 2.3 156 18 151 165 -0.4 0.1 -0.3 -0.8 01/20/2007 02:30:00 3.1 0.4 4.2 2.3 2.8 0.4 3.8 1.9 3.3 0.3 4.2 2.3 155 15 112 165 -0.3 0 -0.1 -0.5 01/20/2007 02:40:00 2.7 0.6 3.8 1.5 2.4 0.6 3.4 0.7 2.7 0.6 3.8 1.5 157 8 155 165 -0.3 0 -0.1 -0.5 01/20/2007 02:50:00 2.7 0.4 3.8 1.9 2.5 0.4 3.4 1.5 2.8 0.3 3.8 2.3 147 6 147 165 -0.3 0 -0.3 -0.5 01/20/2007 03:00:00 2 0.4 3 1.1 1.8 0.4 3 1.1 2.1 0.4 3 0.7 130 6 137 165 -0.4 0 -0.3 -0.8 01/20/2007 03:10:00 2.9 0.8 4.6 1.5 2.8 0.8 4.6 1.5 2.9 0.8 4.6 1.5 126 8 131 165 -0.5 0 -0.3 -0.5 01/20/2007 03:20:00 4.5 0.6 5.7 3 4.5 0.5 5.7 2.6 4.6 0.6 5.7 2.6 135 6 130 165 -0.3 0 -0.1 -0.5 01/20/2007 03:30:00 5.7 0.6 7.2 4.6 5.6 0.6 7.2 4.6 5.8 0.6 7.6 4.6 140 6 143 165 -0.2 0 -0.1 -0.3 01/20/2007 03:40:00 5.5 0.5 6.8 4.2 5.4 0.5 6.8 4.2 5.6 0.6 6.8 3.8 138 8 156 165 -0.2 0 -0.1 -0.3 01/20/2007 03:50:00 5.5 0.4 6.5 4.2 5.4 0.4 6.5 4.6 5.6 0.4 6.5 4.6 138 4 137 165 -0.2 0 -0.1 -0.3 01/20/2007 04:00:00 5.6 0.4 6.8 4.6 5.6 0.4 7.2 4.2 5.7 0.4 6.8 4.6 135 5 138 165 -0.1 0 0.2 -0.1 01/20/2007 04:10:00 5.1 0.6 6.5 3.4 5.1 0.6 6.5 3.4 5.1 0.7 6.8 3.4 132 5 122 165 0 0 0.2 -0.1 01/20/2007 04:20:00 4.2 0.4 5.3 3.4 4.1 0.4 5.3 3.4 4.3 0.4 5.3 3 138 6 137 165 -0.1 0 0.2 -0.3 01/20/2007 04:30:00 4.3 0.8 7.2 3 4.2 0.8 7.2 3 4.5 0.7 7.6 3.4 135 7 118 165 0.1 0 0.2 -0.1 01/20/2007 04:40:00 7.1 0.9 9.1 4.9 7 1 9.1 4.9 7 1 9.9 4.9 139 9 127 165 0.1 0 0.2 -0.1 01/20/2007 04:50:00 4.9 1.2 7.2 2.6 4.7 1.2 6.8 2.6 5 1.2 7.2 2.6 148 16 160 165 -0.2 0.1 0.2 -0.5 01/20/2007 05:00:00 2.9 0.3 3.4 2.3 2.8 0.3 3.4 2.3 3 0.3 3.8 2.3 142 3 140 165 -0.3 0 -0.1 -0.5 01/20/2007 05:10:00 3.1 0.5 4.2 1.9 2.9 0.5 3.8 1.5 3.2 0.4 4.2 2.3 144 6 145 165 -0.4 0 -0.3 -0.5 01/20/2007 05:20:00 2.3 0.6 4.2 1.5 2.2 0.6 3.8 1.1 2.5 0.4 3.4 1.9 129 11 115 165 -0.3 0 -0.1 -0.3 01/20/2007 05:30:00 4.4 0.5 5.3 3 4.4 0.4 5.7 3 4.3 0.6 5.3 2.6 115 5 116 165 -0.2 0 0.2 -0.5 01/20/2007 05:40:00 5.1 1.2 8 2.6 5.1 1.2 8 2.6 5 1.1 7.6 3 110 8 118 165 0 0 0.2 -0.1 01/20/2007 05:50:00 6.2 1.1 8 3 6.2 1.1 8.4 3.4 5.9 1 7.6 4.2 117 7 125 165 0.1 0.1 0.4 -0.1 01/20/2007 06:00:00 8.6 0.7 10.3 6.8 8.8 0.7 10.7 6.8 8.3 0.8 10.3 5.7 101 5 102 165 0.4 0 0.7 0.2 01/20/2007 06:10:00 9.3 0.7 11.1 8 9.5 0.7 11.1 8 9 0.7 10.7 6.8 107 4 108 165 0.5 0 0.7 0.4 01/20/2007 06:20:00 8.4 0.7 9.9 6.1 8.5 0.7 9.9 5.7 8 0.8 9.5 6.1 99 6 102 165 0.5 0 0.7 0.4 01/20/2007 06:30:00 8.4 0.8 9.9 6.1 8.5 0.8 10.3 5.3 7.9 0.8 9.9 6.1 97 5 100 165 0.5 0 0.7 0.2 01/20/2007 06:40:00 7.9 1.2 10.3 4.2 7.9 1.3 10.7 4.2 7.6 1.3 10.7 4.6 103 13 107 165 0.4 0.2 0.7 -0.1 01/20/2007 06:50:00 8.6 0.9 10.7 6.1 8.7 0.9 11.1 6.5 8.1 1 10.3 5.7 102 6 110 165 0.1 0 0.2 -0.1 01/20/2007 07:00:00 8.9 0.7 11.1 7.2 9.1 0.8 11.1 6.8 8.4 0.8 10.7 6.1 96 6 96 165 0.1 0 0.2 -0.1 01/20/2007 07:10:00 9.7 0.8 11.1 7.2 9.9 0.8 11.5 7.2 9.2 0.8 11.1 6.5 82 5 87 165 0.2 0 0.7 -0.1 01/20/2007 07:20:00 7.7 1 9.9 4.6 7.8 1 10.3 4.9 7.5 1.1 9.9 4.6 71 9 85 165 0.3 0 0.7 0.2 01/20/2007 07:30:00 8.1 1 10.3 5.3 8.2 1 10.7 5.7 7.9 0.9 10.3 5.7 75 7 84 165 0.5 0 0.7 0.2 01/20/2007 07:40:00 7 1.1 9.9 4.6 7.1 1.1 9.9 4.9 6.7 1 9.1 4.6 71 8 71 165 0.5 0 0.7 0.2 01/20/2007 07:50:00 8.5 0.9 10.7 6.1 8.6 1 10.7 6.1 8.3 1 9.9 5.7 77 8 81 165 0.6 0 0.9 0.4 01/20/2007 08:00:00 8 1 10.3 4.9 8.1 1 10.3 5.3 7.8 1 9.9 4.6 76 6 78 165 0.6 0 0.9 0.4 01/20/2007 08:10:00 8.2 1 10.7 5.3 8.3 1 11.1 5.7 8 0.9 10.3 6.1 78 7 78 165 0.6 0 0.9 0.4 01/20/2007 08:20:00 7.9 0.9 9.9 5.3 8.1 0.9 9.9 5.7 7.7 0.9 9.9 5.3 70 9 78 165 0.7 0 0.9 0.4 01/20/2007 08:30:00 6.8 0.8 8.8 4.2 6.9 0.8 9.1 4.6 6.6 0.8 9.1 4.6 57 11 66 165 0.5 0 0.7 0.4 01/20/2007 08:40:00 6.6 0.8 8.8 4.6 6.6 0.8 8.8 4.2 6.4 0.8 8.4 4.2 45 9 53 165 0.4 0 0.7 0.2 01/20/2007 08:50:00 10.4 3.2 16.4 4.6 10.5 3.2 16.8 4.6 9.9 3.1 16.1 4.6 77 23 105 165 0.2 0.3 0.7 -0.5 01/20/2007 09:00:00 9.4 1.5 13 6.1 9.6 1.6 13.3 6.1 9.1 1.4 12.2 5.7 95 8 107 165 -0.4 0.2 -0.1 -0.8 01/20/2007 09:10:00 9.1 0.9 11.5 6.8 9.2 1 11.8 6.8 8.6 1 11.1 6.5 94 8 108 165 0.1 0.1 0.2 -0.1 01/20/2007 09:20:00 8.9 1.5 12.2 5.7 9 1.5 12.6 5.3 8.7 1.4 12.2 5.7 61 11 63 165 0.2 0 0.4 -0.1 01/20/2007 09:30:00 5.8 0.7 8 4.2 5.8 0.7 7.6 4.2 5.8 0.8 7.6 3.8 44 9 61 165 0 0 0.2 -0.1 01/20/2007 09:40:00 6.1 1 9.1 3.8 6.2 1 9.1 3.4 6 1 8.8 3.8 44 9 50 165 0.1 0 0.2 -0.1 01/20/2007 09:50:00 6.9 1.5 13.3 3.8 6.9 1.5 13.7 3.8 6.6 1.4 13.3 3.8 48 12 50 165 0.2 0 0.4 -0.1 01/20/2007 10:00:00 12.4 1.5 15.6 8 12.6 1.6 16.1 7.6 12 1.5 15.3 8.4 84 6 84 165 -0.1 0.1 0.2 -0.3 01/20/2007 10:10:00 10.5 1.2 13.3 7.2 10.6 1.3 13.3 7.6 10.3 1.2 13.3 7.6 76 8 66 165 -0.3 0 -0.1 -0.5 01/20/2007 10:20:00 8.9 1 11.8 6.1 9 1.1 11.8 5.7 8.7 1.1 11.1 5.3 73 7 71 165 -0.5 0 -0.3 -0.5 01/20/2007 10:30:00 7.7 1.3 11.1 4.6 7.8 1.3 11.1 4.6 7.6 1.3 10.7 3.8 63 11 73 165 -0.5 0.1 -0.3 -0.8 01/20/2007 10:40:00 7.9 1.2 11.1 4.9 7.9 1.3 11.1 4.9 7.6 1.3 10.7 4.2 48 9 48 165 -0.3 0 -0.1 -0.5 01/20/2007 10:50:00 9.1 1.7 13.7 5.3 9 1.7 13.7 5.3 8.7 1.9 13.7 4.9 43 10 49 165 -0.3 0 -0.1 -0.5 01/20/2007 11:00:00 9.3 1.6 14.1 4.2 9.1 1.6 14.5 4.2 8.9 1.5 13.7 4.9 36 10 46 165 -0.4 0 -0.3 -0.5 01/20/2007 11:10:00 9.1 1.4 12.6 5.3 8.9 1.4 12.2 4.9 8.9 1.3 13.3 5.3 36 11 23 165 -0.2 0 -0.1 -0.5 01/20/2007 11:20:00 11.4 1.7 16.4 5.7 11.3 1.8 16.4 5.7 11.1 1.7 16.1 5.7 38 11 53 165 -0.1 0 0.2 -0.1 01/20/2007 11:30:00 11.4 2.4 16.8 6.1 11.3 2.4 17.2 6.5 11 2.3 17.2 6.5 36 12 26 165 -0.2 0 -0.1 -0.3 01/20/2007 11:40:00 11.5 1.5 14.9 7.6 11.2 1.6 14.9 7.2 11 1.6 15.3 6.8 25 9 36 165 -0.2 0 0.2 -0.3 01/20/2007 11:50:00 11.5 1.5 15.6 7.2 11.4 1.6 15.6 7.2 11.1 1.7 16.1 6.8 37 9 43 165 0.1 0 0.2 -0.1 01/20/2007 12:00:00 11 2 16.4 6.5 10.7 2.1 16.1 6.5 10.5 2 15.3 6.5 34 8 50 165 0.1 0 0.2 -0.1 01/20/2007 12:10:00 13.5 2.6 19.1 7.6 13.1 2.7 18.7 6.5 12.9 2.6 18.7 6.8 34 0 34 165 0.2 0 0.2 -0.1 01/20/2007 12:20:00 13.3 2.1 19.5 7.6 12.9 2.3 19.5 6.8 12.9 2.4 19.5 7.2 34 0 34 165 0.2 0 0.4 0.2 01/20/2007 12:30:00 13.7 2.2 17.9 7.6 13.1 2.3 17.9 6.8 13.2 2.2 18.3 8 34 0 34 165 0.2 0 0.4 0.2 01/20/2007 12:40:00 14.8 2.1 19.1 8.8 13.9 2.4 18.3 6.8 14.6 2.2 19.9 8.4 34 0 34 165 0.2 0 0.4 -0.1 01/20/2007 12:50:00 14.2 1.9 19.1 9.9 13.2 2.3 17.6 6.8 13.8 2.1 20.2 9.1 34 0 34 165 0.2 0 0.4 0.2 01/20/2007 13:00:00 13.4 1.8 17.2 8.4 12.8 2 16.8 6.8 13.1 1.9 17.6 8.8 34 0 34 165 0.2 0 0.7 0.2 01/20/2007 13:10:00 12 1.3 15.3 8 10.3 2 14.9 4.9 11.7 1.5 15.6 8.4 34 0 34 165 0.2 0 0.4 0.2 01/20/2007 13:20:00 12.8 1.6 16.8 9.5 9.8 2.4 15.3 4.2 12.8 1.7 17.2 8.8 33 0 34 165 0.2 0 0.4 0.2 01/20/2007 13:30:00 13.4 1.5 17.2 9.1 11.9 2.1 16.8 6.1 13.4 1.6 17.2 9.1 33 0 34 165 0.2 0 0.4 0.2 01/20/2007 13:40:00 13.3 1.7 17.2 8.4 10.8 2.8 16.1 4.6 13.2 1.7 17.2 8.8 33 0 34 165 0.2 0 0.4 0.2 01/20/2007 13:50:00 11.6 1.4 15.3 6.5 9.6 2.1 13.7 3.8 11.6 1.5 16.1 6.8 33 0 34 165 0.2 0 0.4 0.2 01/20/2007 14:00:00 11.7 1.3 14.1 8 10 2.3 13.7 3.4 11.6 1.7 15.3 7.2 33 0 34 165 0.3 0 0.7 0.2 01/20/2007 14:10:00 12.5 1.7 17.2 8.4 7.9 2.9 15.3 2.6 12.5 1.9 18.3 8.4 33 0 34 165 0.2 0 0.7 0.2 01/20/2007 14:20:00 13.1 1.6 17.6 9.5 9.1 3.1 16.4 3 13.2 1.9 17.9 8.4 33 0 34 165 0.2 0 0.4 0.2 01/20/2007 14:30:00 12.4 1.3 16.1 9.1 7.8 3.1 15.6 3 12.6 1.5 17.2 8.8 33 0 34 165 0.2 0 0.7 0.2 01/20/2007 14:40:00 12.6 1.9 16.8 8 8 3.8 16.1 2.3 12.9 2.2 17.9 8 33 0 34 165 0.2 0 0.7 0.2 01/20/2007 14:50:00 12.4 1.3 16.8 8.8 7.5 2.8 15.6 2.6 12.8 1.5 18.3 8.8 33 0 34 165 0.3 0 0.7 0.2 01/20/2007 15:00:00 11.1 1.6 15.6 7.2 6.7 2.5 12.6 2.3 10.9 1.8 15.3 6.8 33 0 34 165 0.3 0 0.7 0.2 01/20/2007 15:10:00 11.7 1.8 16.1 7.2 7.6 2.7 15.6 3 11.9 2.2 16.8 6.5 33 0 34 165 0.3 0 0.7 0.2 01/20/2007 15:20:00 12.7 1.7 17.2 9.1 7.9 2.7 15.3 1.9 13.1 1.7 16.8 9.5 33 0 34 165 0.3 0 0.7 0.2 01/20/2007 15:30:00 12.4 1.6 16.4 7.2 9.2 2.1 15.3 4.9 12.8 1.8 17.9 8 33 0 34 165 0.3 0 0.7 0.2 01/20/2007 15:40:00 12.2 1.5 16.8 9.1 8.5 2 16.1 4.9 12.6 1.7 17.6 8.4 33 0 34 165 0.3 0 0.7 0.2 01/20/2007 15:50:00 12.2 1.9 17.2 7.2 9.7 2.2 16.1 4.2 12.7 2.1 18.3 8 33 0 34 165 0.4 0 0.7 0.2 01/20/2007 16:00:00 12.2 2.4 18.7 7.2 9.4 2 15.3 4.2 12.6 2.5 19.1 6.8 33 0 34 165 0.4 0 0.7 0.2 01/20/2007 16:10:00 13.9 1.9 19.5 9.9 10.3 2.3 16.4 6.1 14.5 2.3 19.5 9.5 33 0 34 165 0.4 0 0.7 0.2 01/20/2007 16:20:00 13.9 1.8 19.1 10.3 10 1.8 16.1 6.1 14.4 2 19.9 9.9 33 0 34 165 0.4 0 0.7 0.2 01/20/2007 16:30:00 14.5 2.2 20.2 9.1 11.5 2.1 18.3 6.8 15 2.3 22.1 9.1 33 0 34 165 0.4 0 0.7 0.2 01/20/2007 16:40:00 15.6 1.5 20.2 11.8 12 2.3 18.7 7.6 15.9 1.7 21.8 11.5 33 0 34 165 0.4 0 0.7 0.2 01/20/2007 16:50:00 14.4 1.9 19.9 9.5 11.9 2.1 18.3 7.6 15.2 2.2 20.6 8.8 33 0 34 165 0.5 0 0.7 0.2 01/20/2007 17:00:00 16.6 2.5 22.1 11.1 12.4 2.8 20.6 7.6 17.2 2.6 22.9 10.7 33 0 34 165 0.5 0 0.7 0.2 01/20/2007 17:10:00 15.4 2 22.1 11.5 12.3 2.2 20.2 8.4 15.7 2.1 22.9 11.8 33 0 34 165 0.5 0 0.7 0.2 01/20/2007 17:20:00 14.2 2.6 22.6 8.8 11.7 3.2 19.5 4.6 14.8 2.7 25.2 9.9 33 0 34 165 0.3 0.1 0.9 0.2 01/20/2007 17:30:00 11 2.8 18.7 3 10 2.8 17.2 3 11.9 3.1 20.6 3 33 0 34 165 0.1 0 0.2 -0.1 01/20/2007 17:40:00 12.2 1.5 16.4 8 12.5 1.7 17.6 8 13.3 1.9 17.6 8.8 33 0 34 165 -0.1 0 0.2 -0.3 01/20/2007 17:50:00 10.7 1.7 15.3 6.1 10.9 1.8 15.6 6.1 11.7 2 16.4 6.8 33 0 33 165 -0.1 0 0.2 -0.3 01/20/2007 18:00:00 12.1 2.7 20.2 6.8 12.2 2.7 19.9 6.8 13.2 3.1 21.4 7.2 33 0 33 165 -0.1 0 0.2 -0.3 01/20/2007 18:10:00 13.2 2.4 19.1 8 13.3 2.4 20.2 8 14.4 2.8 21 7.6 33 0 34 165 0.1 0 0.2 -0.1 01/20/2007 18:20:00 15.4 3.1 24.8 9.5 15.4 3.1 25.6 9.5 16.9 3.5 26.8 9.1 33 0 33 165 0.1 0 0.2 -0.1 01/20/2007 18:30:00 15.2 3.3 23.7 7.6 15.1 3.2 24.4 7.6 16.6 3.5 27.1 8.4 33 0 33 165 0.1 0 0.4 -0.1 01/20/2007 18:40:00 16.3 2.9 24.8 9.9 16.1 3.2 25.2 9.1 17.8 3.1 26 10.7 33 0 33 165 0.2 0 0.2 0.2 01/20/2007 18:50:00 14.6 3.1 22.9 8.8 14.6 2.9 22.9 9.1 15.8 3.2 25.2 9.1 33 0 33 165 0.1 0 0.4 -0.1 01/20/2007 19:00:00 14.1 2.7 21 8.4 14.4 2.7 21 8.8 15.3 2.9 22.9 9.1 33 0 33 165 0.2 0 0.4 -0.1 01/20/2007 19:10:00 14.2 2.5 20.6 8.8 14.5 2.5 21.4 8.4 15.5 2.7 22.1 9.9 33 0 33 165 0.1 0 0.4 -0.1 01/20/2007 19:20:00 13.7 3.2 23.7 6.5 14 3.2 24 6.5 14.7 3.3 26.3 8 33 0 33 165 0.1 0 0.4 -0.1 01/20/2007 19:30:00 14.1 2.4 22.1 9.1 14.6 2.5 23.3 9.1 15.1 2.8 22.9 9.9 33 0 33 165 0 0 0.4 -0.1 01/20/2007 19:40:00 14.1 2.2 21.4 9.5 14.9 2.3 21.8 8.8 15.3 2.5 22.1 9.5 33 0 33 165 -0.1 0 0.2 -0.3 01/20/2007 19:50:00 14.7 2.7 22.9 8.8 15.3 2.6 23.3 9.1 15.8 2.9 26 9.5 33 0 33 165 -0.1 0 0.2 -0.3 01/20/2007 20:00:00 13.6 2.1 20.2 9.1 14.3 2.1 21.4 10.3 14.8 2.3 21 9.5 33 0 33 165 -0.2 0.1 0.2 -0.5 01/20/2007 20:10:00 12.8 1.5 18.7 8.8 13.6 1.6 18.7 8.8 13.7 1.8 20.6 9.1 33 0 33 165 -0.2 0 -0.1 -0.3 01/20/2007 20:20:00 14.5 3.1 24 8.4 15.1 3.1 25.6 8.8 15.7 3.2 26.3 9.9 33 0 33 165 -0.2 0 0.2 -0.3 01/20/2007 20:30:00 14.1 1.9 20.6 9.9 14.9 2 21.4 10.3 15.2 2.2 20.6 10.3 33 0 33 165 -0.2 0 0.2 -0.3 01/20/2007 20:40:00 14.7 2.1 22.6 9.5 15.5 2.3 23.3 9.5 16 2.6 24.8 9.5 33 0 33 165 -0.2 0 -0.1 -0.3 01/20/2007 20:50:00 14.3 2 20.2 9.9 15.2 2 21.4 10.7 15.4 2.4 24 10.7 33 0 33 165 -0.3 0 -0.1 -0.5 01/20/2007 21:00:00 14.6 1.9 20.6 9.5 15.6 2 21.8 10.3 15.8 2.3 22.6 10.7 33 0 33 165 -0.3 0 -0.1 -0.5 01/20/2007 21:10:00 14.4 1.6 20.2 10.3 15.4 1.7 20.6 11.1 15.5 2.1 21 9.1 33 0 33 165 -0.3 0 -0.3 -0.5 01/20/2007 21:20:00 15.4 2.1 22.1 8.8 16.4 2.3 22.9 9.1 16.5 2.5 23.7 10.7 33 0 33 165 -0.3 0 -0.1 -0.5 01/20/2007 21:30:00 14.7 1.8 19.5 8.4 15.7 2 21 9.5 16.1 2.2 21 10.7 33 0 33 165 -0.4 0 -0.3 -0.5 01/20/2007 21:40:00 15.2 2.3 23.7 11.1 16.3 2.4 23.7 11.5 17 2.4 24.4 11.8 33 0 33 165 -0.3 0 -0.3 -0.5 01/20/2007 21:50:00 13.8 1.7 19.5 9.5 14.8 1.7 19.9 9.9 14.7 2 20.2 9.9 33 0 33 165 -0.5 0 -0.3 -0.8 01/20/2007 22:00:00 14.7 2.5 22.6 10.3 15.7 2.6 25.2 10.7 16 2.8 26.3 10.7 33 0 33 165 -0.4 0 -0.1 -0.5 01/20/2007 22:10:00 17.1 2.7 25.2 10.3 18.5 2.8 26.8 10.7 19.1 3.1 27.9 11.8 33 0 33 165 -0.2 0 -0.1 -0.5 01/20/2007 22:20:00 17.9 2.5 24 12.2 19.2 2.6 26 12.6 19.5 2.8 27.5 13.7 33 0 33 165 -0.2 0 0.2 -0.3 01/20/2007 22:30:00 17.6 2.4 23.3 11.5 19 2.5 24.8 12.2 19.1 2.8 28.3 12.2 33 0 32 165 -0.2 0 0.2 -0.3 01/20/2007 22:40:00 16.5 2.2 21.8 12.2 17.8 2.3 22.9 13 18.7 2.3 23.7 12.2 33 0 33 165 -0.2 0 0.2 -0.3 01/20/2007 22:50:00 15.4 2.2 22.6 11.5 16.6 2.3 23.7 11.8 17.1 2.2 23.7 13 33 0 32 165 -0.2 0 0.2 -0.3 01/20/2007 23:00:00 15.8 1.8 22.1 12.2 17.1 1.8 23.3 13.3 17.6 2.1 22.9 11.8 32 0 32 165 -0.2 0 -0.1 -0.5 01/20/2007 23:10:00 15.3 2.3 21.4 11.1 16.4 2.3 22.1 11.8 16.9 2.2 23.3 12.2 32 0 32 165 -0.2 0.1 -0.1 -0.5 01/20/2007 23:20:00 14.9 1.6 20.2 11.5 16 1.5 20.6 12.6 16.1 1.7 21.8 10.3 32 0 32 165 -0.4 0 -0.1 -0.8 01/20/2007 23:30:00 14.6 1.7 20.2 11.1 15.8 1.9 21.4 11.8 16.1 2.3 22.6 10.3 32 0 32 165 -0.4 0 -0.1 -0.5 01/20/2007 23:40:00 16 1.9 22.6 11.1 17.2 1.9 24 12.6 17.5 1.8 22.9 13.3 32 0 32 165 -0.3 0 -0.1 -0.5 01/20/2007 23:50:00 17 1.8 22.1 12.2 18.5 1.9 22.9 13.3 19.2 2.2 26.3 14.5 32 0 32 165 -0.3 0 -0.1 -0.5 01/21/2007 00:00:00 17.1 1.7 23.7 13 18.6 1.7 24.8 13.7 18.9 2 24.8 13.7 32 0 32 165 -0.4 0 -0.3 -0.8 01/21/2007 00:10:00 18.2 2.4 24.4 13.3 19.7 2.4 26 14.5 20.4 2.7 27.9 14.9 32 0 32 165 -0.5 0.1 -0.1 -0.8 01/21/2007 00:20:00 20.2 1.3 24 16.4 22.3 1.4 26.3 18.3 23.3 1.8 27.5 17.2 32 0 32 165 -0.5 0 -0.3 -0.5 01/21/2007 00:30:00 19.9 1.8 26.3 15.6 21.9 2 29.8 17.6 23 2.2 31.3 18.3 32 0 32 165 -0.5 0 -0.1 -0.8 01/21/2007 00:40:00 20 1.3 22.9 16.8 21.8 1.4 25.2 18.3 23 1.7 26.8 17.6 32 0 32 165 -0.6 0 -0.5 -0.8 01/21/2007 00:50:00 21.9 1.5 25.6 16.8 23.8 1.5 27.5 18.7 25.2 1.9 29.1 19.1 31 0 31 165 -0.6 0 -0.3 -0.8 01/21/2007 01:00:00 21.2 1.2 24.8 17.6 23.1 1.3 27.5 18.3 24.8 1.6 29.8 19.9 31 0 31 165 -0.5 0 -0.3 -0.8 01/21/2007 01:10:00 19.8 1.3 24.4 16.8 21.2 1.3 25.2 17.6 22.2 1.7 26.8 16.8 30 0 31 165 -0.6 0 -0.3 -0.8 01/21/2007 01:20:00 19.4 1.2 22.1 15.6 20.8 1.3 23.3 16.4 22.1 1.4 24.8 17.6 29 0 30 165 -0.5 0 -0.3 -0.8 01/21/2007 01:30:00 17.3 1.3 21 14.1 18.3 1.3 22.1 14.1 19 1.7 23.7 14.1 29 0 29 165 -0.6 0 -0.3 -0.8 01/21/2007 01:40:00 16 1.6 21.4 13 16.9 1.7 22.1 14.1 17.6 1.8 22.9 13 29 0 29 165 -0.6 0 -0.5 -0.8 01/21/2007 01:50:00 15.1 1.3 18.3 11.5 15.7 1.3 19.1 11.8 15 1.6 17.9 10.7 28 0 29 165 -0.6 0 -0.3 -0.8 01/21/2007 02:00:00 14.5 1.1 17.2 11.1 14.8 1.1 17.6 11.8 13 1.5 17.6 9.5 28 0 28 165 -0.7 0 -0.5 -0.8 01/21/2007 02:10:00 12.6 1.2 15.3 9.1 12.9 1.2 15.6 9.9 11.6 1.5 16.4 8 28 0 28 165 -0.7 0 -0.5 -0.8 01/21/2007 02:20:00 10 1.3 13.7 7.2 10.1 1.3 14.1 7.2 8.9 1.5 12.6 6.1 28 0 28 165 -0.8 0 -0.5 -0.8 01/21/2007 02:30:00 9.9 0.9 12.2 7.6 10 0.8 12.2 7.6 8.1 1.3 13.3 5.3 28 0 28 165 -0.8 0 -0.5 -1 01/21/2007 02:40:00 10.9 1.4 14.1 7.6 11 1.4 14.1 7.6 8.8 1.3 13.7 5.7 28 0 28 165 -0.8 0 -0.5 -0.8 01/21/2007 02:50:00 10.6 1 13.3 8 10.6 1 13.3 7.6 8.1 1.2 12.2 5.3 28 0 28 165 -0.8 0 -0.5 -0.8 01/21/2007 03:00:00 10.2 1.1 13.3 8 10.3 1.1 13.3 8 9.4 1.9 14.1 5.7 27 0 28 165 -0.8 0 -0.5 -1 01/21/2007 03:10:00 10.5 0.8 12.6 8.4 10.5 0.8 12.6 8.4 7.9 0.8 11.5 6.5 27 0 28 165 -1 0 -0.8 -1.2 01/21/2007 03:20:00 10 1 13.3 7.6 10.1 1 13.3 8 8 1.1 11.8 6.1 27 0 27 165 -1.2 0 -1 -1.4 01/21/2007 03:30:00 9.1 1.2 13 6.8 9.2 1.2 13.3 7.2 8.3 1.7 13.7 5.3 27 0 27 165 -1.1 0 -0.8 -1.2 01/21/2007 03:40:00 10.5 1.3 13.7 7.6 10.6 1.3 14.1 7.6 9.7 2 14.5 5.7 27 0 27 165 -0.9 0 -0.8 -1.2 01/21/2007 03:50:00 9.1 0.8 11.1 7.2 9.2 0.8 11.1 7.2 7.4 1.3 11.5 5.3 27 0 27 165 -1.2 0 -1 -1.4 01/21/2007 04:00:00 7.4 1.9 11.1 3.8 7.5 1.8 11.1 3.4 6.9 1.4 11.1 3.8 27 0 27 165 -1.2 0 -1 -1.4 01/21/2007 04:10:00 4 0.6 6.1 2.3 4.6 0.5 6.5 3 4.8 0.5 6.1 3.4 27 0 27 165 -0.9 0.1 -0.8 -1.2 01/21/2007 04:20:00 6.3 1.3 8.8 3.8 6.3 1.3 8.8 3.8 6 1.2 9.1 3.4 27 0 27 165 -1.1 0 -0.8 -1.2 01/21/2007 04:30:00 7.9 1 10.3 5.3 8 1 10.3 5.7 7.2 1.2 9.9 4.2 27 0 27 165 -1.2 0 -0.8 -1.4 01/21/2007 04:40:00 8.9 1.9 13.3 5.3 9 1.9 13.3 5.7 8 2.3 13.7 4.6 343 51 279 165 -1.2 0 -1 -1.4 01/21/2007 04:50:00 9.8 1.7 13.3 6.5 10.1 1.8 13.7 6.1 10.1 1.8 14.1 6.5 277 6 279 165 -1.4 0.1 -1.2 -1.7 01/21/2007 05:00:00 10.7 1.2 13 8 10.7 1.2 13 7.6 9.6 1.7 13.3 5.3 286 7 286 165 -1.6 0 -1.4 -1.9 01/21/2007 05:10:00 10.9 0.9 13.7 8.4 11 0.9 13.7 8.4 10.6 1.5 13.3 6.5 284 6 280 165 -1.5 0 -1.4 -1.7 01/21/2007 05:20:00 11.9 0.8 13.7 9.1 12.1 0.8 13.7 9.5 11.7 1.3 14.1 6.5 284 5 285 165 -1.6 0 -1.4 -1.9 01/21/2007 05:30:00 10 1.3 13 7.2 10 1.3 12.6 7.6 8 1.7 13.3 5.3 292 5 287 165 -1.7 0 -1.4 -1.9 01/21/2007 05:40:00 8.6 0.8 10.3 6.8 8.7 0.7 10.7 6.8 7.7 1.1 11.1 5.3 289 5 293 165 -2 0 -1.7 -2.1 01/21/2007 05:50:00 8.9 1.3 11.8 6.1 8.9 1.3 11.1 6.1 6.8 1.4 11.1 4.2 295 7 299 165 -2 0 -1.9 -2.1 01/21/2007 06:00:00 7.5 1.2 10.3 4.6 7.7 1.2 10.7 4.9 6.9 1.7 10.7 3.4 305 8 313 165 -2 0 -1.7 -2.1 01/21/2007 06:10:00 6.1 1.2 9.1 3.4 6.1 1.2 9.1 3.8 5.4 1 8.8 3.4 291 8 286 165 -1.9 0 -1.7 -2.1 01/21/2007 06:20:00 4.8 1.2 7.6 2.6 5.4 1 7.6 3.4 5.4 1.1 8 3.4 275 10 277 165 -2 0.2 -1.4 -2.4 01/21/2007 06:30:00 6.8 0.6 8 4.9 6.9 0.6 8.4 5.3 6.7 0.7 8.4 4.2 284 4 285 165 -2.3 0 -2.1 -2.6 01/21/2007 06:40:00 5.5 0.6 6.8 3.8 5.5 0.6 6.8 4.2 5.4 0.7 6.8 3.4 283 5 285 165 -2.2 0 -2.1 -2.4 01/21/2007 06:50:00 4.8 0.6 6.1 3 5.4 0.5 6.5 4.2 5.2 0.6 6.5 3 274 7 274 165 -2.3 0.1 -2.1 -2.6 01/21/2007 07:00:00 6.5 0.5 7.6 5.3 6.7 0.5 8 5.3 6.7 0.7 8.4 4.6 280 4 282 165 -2.5 0 -2.4 -2.6 01/21/2007 07:10:00 5.1 1 7.2 2.6 6.1 0.6 7.6 4.2 5.8 0.7 7.2 3.8 271 7 281 165 -2.6 0 -2.1 -2.8 01/21/2007 07:20:00 6 0.5 7.2 4.6 6.2 0.5 7.6 4.6 6.3 0.7 7.6 4.2 282 4 282 165 -2.5 0.1 -2.1 -3 01/21/2007 07:30:00 6.6 1 8.4 4.2 6.7 1 8.8 4.2 6.1 1.1 8.4 3.8 288 4 292 165 -2.5 0.1 -2.4 -2.8 01/21/2007 07:40:00 6.8 0.6 8.4 4.9 6.9 0.6 8.4 5.3 5.9 0.9 8 3.8 290 4 284 165 -2.7 0 -2.6 -2.8 01/21/2007 07:50:00 6.4 0.5 8 5.3 6.5 0.5 8 5.3 5.3 0.8 7.6 3.4 291 5 285 165 -2.9 0.1 -2.6 -3 01/21/2007 08:00:00 6.7 0.6 8.8 4.9 6.9 0.6 8.8 5.3 5.3 0.7 8 3.8 295 6 301 165 -2.9 0 -2.8 -3 01/21/2007 08:10:00 6.3 0.9 8 4.6 6.4 0.8 8.4 4.6 5 1 8.4 3 294 6 291 165 -3 0.1 -2.8 -3.3 01/21/2007 08:20:00 6.6 0.7 8.4 4.9 6.7 0.7 8.4 4.9 5.8 0.9 8.4 3.8 292 8 290 165 -3.2 0 -3 -3.5 01/21/2007 08:30:00 6.4 0.7 8.4 4.6 6.6 0.7 8.4 4.9 5.1 0.8 7.6 3 299 7 297 165 -3.3 0 -3 -3.5 01/21/2007 08:40:00 7.4 1 9.1 4.9 7.5 1 9.1 4.9 5.9 1.2 8.4 3.4 294 5 292 165 -3.5 0.1 -3.3 -3.7 01/21/2007 08:50:00 6.6 1.2 9.5 4.9 6.7 1.2 9.9 4.9 5.7 1.6 10.3 3.4 290 6 284 165 -3.8 0.1 -3.5 -4.2 01/21/2007 09:00:00 6.1 0.6 7.6 4.6 6.2 0.6 8 4.6 4.8 0.6 6.5 3.4 301 7 292 165 -4.2 0 -3.9 -4.4 01/21/2007 09:10:00 6 0.6 7.6 4.6 6.1 0.6 7.6 4.6 4.7 1 7.2 3 303 6 306 165 -4.3 0 -4.2 -4.6 01/21/2007 09:20:00 5.3 0.5 6.5 4.2 5.4 0.5 6.8 4.2 4.2 0.6 5.7 3 304 6 303 165 -4.3 0 -4.2 -4.6 01/21/2007 09:30:00 5.3 0.5 6.8 3.8 5.4 0.5 6.8 3.8 4.6 0.7 6.5 3 308 6 315 165 -4.4 0 -4.2 -4.6 01/21/2007 09:40:00 5.6 0.6 6.8 4.2 5.7 0.6 7.2 4.2 4.5 0.8 6.5 3 298 9 308 165 -4.5 0 -4.4 -4.6 01/21/2007 09:50:00 5 0.4 6.1 3.8 5 0.4 6.1 4.2 4 0.7 6.1 2.6 294 5 296 165 -4.4 0 -4.4 -4.6 01/21/2007 10:00:00 3.7 0.6 5.3 2.6 3.6 0.6 5.3 2.3 3.2 0.8 4.9 1.9 291 6 284 165 -4.2 0.1 -3.9 -4.6 01/21/2007 10:10:00 4.7 0.5 5.7 3.4 4.7 0.5 5.7 3.4 3.5 0.6 5.7 2.3 297 6 295 165 -4.1 0.1 -3.9 -4.4 01/21/2007 10:20:00 4.9 0.7 6.5 3.4 4.9 0.7 6.8 3.4 3.8 0.8 5.7 2.3 302 6 314 165 -4 0 -3.7 -4.2 01/21/2007 10:30:00 5.5 0.7 7.2 3.8 5.5 0.7 7.2 4.2 4.2 0.6 6.1 3 304 5 305 165 -4 0 -3.7 -4.2 01/21/2007 10:40:00 5 0.8 6.8 3.4 5 0.8 6.8 3.4 4 0.8 6.1 2.3 301 8 302 165 -3.9 0 -3.7 -4.2 01/21/2007 10:50:00 5.4 0.8 6.8 3.4 5.4 0.8 6.8 3.8 3.9 0.6 6.5 2.3 298 4 297 165 -3.9 0 -3.5 -4.2 01/21/2007 11:00:00 4.8 0.4 5.7 3.8 4.7 0.4 5.7 3.8 3.8 0.5 5.3 2.6 292 6 299 165 -3.8 0 -3.5 -4.2 01/21/2007 11:10:00 4 0.4 4.9 3 3.9 0.4 4.9 2.6 3.1 0.4 4.2 1.9 294 4 293 165 -3.7 0 -3.5 -3.9 01/21/2007 11:20:00 4.1 0.4 4.9 3 4 0.4 4.9 3 2.9 0.5 4.6 1.9 295 4 293 165 -3.5 0 -3.3 -3.9 01/21/2007 11:30:00 4.4 0.5 5.7 3.4 4.4 0.5 5.3 3.4 3.6 0.6 4.9 2.3 291 5 297 165 -3.7 0 -3.5 -3.9 01/21/2007 11:40:00 3.6 0.6 5.3 2.6 3.6 0.6 5.3 2.6 2.8 0.8 4.9 1.5 302 8 302 165 -3.4 0.1 -3 -3.9 01/21/2007 11:50:00 3.8 0.4 4.9 2.6 3.7 0.4 4.9 2.6 3 0.7 4.9 1.5 295 4 300 165 -3.4 0.2 -3 -3.5 01/21/2007 12:00:00 4.5 0.5 6.1 3 4.5 0.5 6.1 3 3.3 0.5 4.6 2.3 296 4 295 165 -3.6 0 -3.5 -3.7 01/21/2007 12:10:00 5.1 0.4 6.1 4.2 5.1 0.4 6.1 4.2 4.4 0.7 5.7 2.6 286 5 281 165 -3.8 0 -3.5 -3.9 01/21/2007 12:20:00 4.4 0.6 5.7 2.6 4.6 0.5 5.7 3.4 4.3 0.6 5.7 2.3 280 6 282 165 -3.7 0.1 -3.5 -3.9 01/21/2007 12:30:00 5.6 0.5 6.5 4.2 5.5 0.5 6.5 4.2 5 0.6 6.1 3.4 285 4 287 165 -3.6 0 -3.3 -3.7 01/21/2007 12:40:00 4.8 0.5 6.1 3.4 4.9 0.5 6.1 3.8 4.6 0.5 5.7 3.4 276 4 276 165 -3.6 0 -3.3 -3.7 01/21/2007 12:50:00 4.8 0.5 6.1 3.4 5 0.4 5.7 3.4 4.7 0.4 5.7 3.4 276 4 273 165 -3.7 0 -3.5 -3.9 01/21/2007 13:00:00 3.4 0.5 4.9 1.9 4.2 0.4 5.3 3 4 0.5 5.3 3 262 3 268 165 -3.4 0 -3.3 -3.9 01/21/2007 13:10:00 3.8 0.5 4.9 2.3 4.1 0.4 4.9 3.4 3.9 0.4 4.6 3 270 5 270 165 -3.4 0.1 -3 -3.5 01/21/2007 13:20:00 3.2 0.5 4.2 2.3 3.7 0.3 4.6 2.3 3.6 0.3 4.6 3 262 6 274 165 -3.2 0.1 -2.8 -3.5 01/21/2007 13:30:00 2.2 0.4 3.4 1.1 2.3 0.5 3.4 1.1 2.2 0.5 3.4 1.1 238 17 261 165 -2.6 0.3 -1.9 -3 01/21/2007 13:40:00 2.1 0.4 3 1.1 2.1 0.4 3 1.1 1.8 0.4 2.6 0.7 233 8 245 165 -2 0.1 -1.7 -2.6 01/21/2007 13:50:00 1.8 0.5 3 0.7 1.8 0.5 3 0.7 1.8 0.6 3 0.4 202 19 207 165 -1.8 0 -1.4 -2.1 01/21/2007 14:00:00 1.8 0.5 3 0.7 1.8 0.5 3 0.7 1.5 0.4 2.6 0.7 240 14 246 165 -1.8 0 -1.4 -2.1 01/21/2007 14:10:00 1.3 0.7 3 0.4 1.2 0.7 3 0.4 1.1 0.7 3 0.4 217 35 189 165 -1.6 0.1 -1.2 -1.9 01/21/2007 14:20:00 2.8 0.9 5.7 1.5 2.7 0.9 5.7 1.1 2.8 0.8 5.3 1.1 191 13 215 165 -1.8 0.2 -1.2 -2.1 01/21/2007 14:30:00 4.7 1 6.8 2.3 4.6 1 6.8 2.3 4.4 0.9 6.5 2.3 204 10 205 165 -2.5 0.1 -2.1 -2.8 01/21/2007 14:40:00 5.5 1.1 8 2.6 5.4 1.1 8 2.6 5.1 1 7.6 2.3 204 9 206 165 -3 0.2 -2.6 -3.5 01/21/2007 14:50:00 5.6 1 7.6 3.4 5.7 1 8 3.4 5.3 1 7.6 3 216 7 207 165 -3.1 0.1 -2.8 -3.5 01/21/2007 15:00:00 4.4 0.7 6.1 2.3 4.5 0.7 6.1 2.3 4.2 0.6 5.7 2.6 220 12 213 165 -3 0 -2.8 -3.5 01/21/2007 15:10:00 2.3 0.9 4.6 0.4 2.3 0.9 4.9 0.4 2.2 0.8 4.9 0.4 220 16 231 165 -2.8 0.2 -2.4 -3.5 01/21/2007 15:20:00 1.4 0.6 3 0.4 1.4 0.6 3 0.4 1.3 0.7 3.4 0.4 242 22 238 165 -2.3 0 -1.9 -2.6 01/21/2007 15:30:00 2.9 1.1 5.3 0.7 3 1.1 5.3 0.4 2.8 1.2 5.7 0.4 234 23 223 165 -2.6 0.4 -1.9 -3.5 01/21/2007 15:40:00 5.2 1.7 10.3 2.3 5.3 1.7 10.3 2.6 4.7 1.6 9.1 1.9 215 12 215 165 -3.3 0.1 -2.8 -3.5 01/21/2007 15:50:00 8.2 1 10.7 6.1 8.3 1 10.7 6.5 8 1 10.3 5.7 212 4 218 165 -3.6 0.1 -3.3 -4.2 01/21/2007 16:00:00 5.1 1.5 7.6 1.9 5.1 1.4 7.6 1.9 4.6 1.7 7.2 0.4 210 13 209 165 -3.5 0 -3.3 -3.9 01/21/2007 16:10:00 4.1 1.2 6.5 1.5 4.3 1.1 6.5 1.5 4 1 6.5 1.9 248 11 243 165 -3.4 0 -3.3 -3.5 01/21/2007 16:20:00 2.9 0.9 4.9 1.1 3.1 0.7 4.9 1.5 3 0.6 4.6 1.5 264 15 257 165 -3.4 0 -3.3 -3.9 01/21/2007 16:30:00 3.2 1 5.7 1.5 3.4 0.9 6.1 1.5 3.3 0.8 5.7 1.5 241 19 225 165 -3.8 0 -3.5 -4.2 01/21/2007 16:40:00 5.2 1.2 7.6 2.6 5.2 1.2 7.6 2.6 4.7 1.1 7.2 2.3 207 12 211 165 -4.4 0.1 -3.9 -4.6 01/21/2007 16:50:00 6.1 1 8.4 3.4 6.2 1 8.8 3.8 5.6 1 8.4 3 216 7 209 165 -4.7 0.1 -4.4 -5 01/21/2007 17:00:00 5.8 0.6 7.2 4.2 5.9 0.6 7.2 4.2 5.4 0.7 6.8 3.4 214 5 207 165 -4.8 0 -4.6 -5 01/21/2007 17:10:00 5.2 1.1 7.6 3 5.2 1.1 8 3 4.8 1.1 7.2 2.6 216 9 203 165 -4.8 0 -4.6 -5 01/21/2007 17:20:00 6.9 1 9.1 4.2 6.9 1 9.1 4.6 6.5 1 8.8 3.8 203 7 204 165 -4.7 0 -4.4 -5 01/21/2007 17:30:00 7.1 1.2 10.3 4.2 7.1 1.2 10.7 4.6 6.5 1.2 10.7 4.2 206 7 203 165 -4.5 0 -4.4 -4.8 01/21/2007 17:40:00 9.1 1.2 11.5 5.3 9.1 1.2 11.1 5.7 8.5 1.2 11.1 4.6 204 6 198 165 -4.2 0.1 -3.9 -4.4 01/21/2007 17:50:00 8.2 1 10.3 4.9 8.3 1 10.3 4.9 7.7 1 10.7 4.9 210 6 202 165 -4.2 0 -3.9 -4.4 01/21/2007 18:00:00 6.2 1.2 8.8 3.4 6.3 1.2 9.1 3.4 5.7 1.2 8.8 3 214 10 206 165 -4.2 0 -3.9 -4.6 01/21/2007 18:10:00 5.1 1 7.2 1.9 5.1 1 7.6 1.9 4.7 1.1 7.2 2.3 213 11 217 165 -4.3 0 -4.2 -4.6 01/21/2007 18:20:00 4.3 0.8 6.5 2.3 4.2 0.8 6.5 2.3 3.8 0.8 5.7 1.9 209 11 200 165 -4.4 0 -4.2 -4.6 01/21/2007 18:30:00 3.1 1 4.9 0.7 3 1 4.9 0.7 2.7 1.1 5.3 0.4 224 17 221 165 -4.4 0 -4.2 -4.6 01/21/2007 18:40:00 2.7 0.7 4.6 0.7 2.7 0.7 4.6 1.1 2.4 0.6 4.2 0.7 237 17 242 165 -4.3 0 -4.2 -4.6 01/21/2007 18:50:00 4.2 1.2 7.2 0.7 4.2 1.2 6.8 0.4 3.9 1 6.5 0.7 229 14 226 165 -4.2 0.1 -3.9 -4.6 01/21/2007 19:00:00 7.6 1 9.5 3.8 7.7 1 9.5 3.8 7.3 1.1 9.9 4.2 210 6 204 165 -3.7 0.1 -3.5 -4.2 01/21/2007 19:10:00 5.8 1 8 3.4 5.7 1.1 8.4 3.4 5.3 1.1 8 2.6 198 9 202 165 -3.8 0.1 -3.5 -4.2 01/21/2007 19:20:00 3.5 0.9 5.3 0.7 3.3 0.9 4.9 0.4 3.4 0.6 4.9 1.5 160 21 132 165 -4.2 0.1 -3.9 -4.6 01/21/2007 19:30:00 3.7 0.9 5.7 0.4 3.6 0.9 5.3 0.7 3.5 1 5.7 0.4 145 22 171 165 -4.1 0.1 -3.7 -4.6 01/21/2007 19:40:00 2.1 0.7 4.2 0.4 2 0.7 4.2 0.4 2 0.6 3.4 0.4 145 26 205 165 -4 0.1 -3.7 -4.4 01/21/2007 19:50:00 3.1 0.9 5.3 0.7 2.9 0.9 5.3 0.7 2.5 1 5.3 0.4 198 17 199 165 -3.7 0.1 -3.5 -4.2 01/21/2007 20:00:00 4.9 0.7 6.5 2.6 4.6 0.7 6.5 2.3 4.7 0.6 6.5 2.6 173 15 182 165 -3.8 0 -3.5 -3.9 01/21/2007 20:10:00 4.6 0.7 6.1 3 4.3 0.7 5.7 3 4.4 0.7 5.7 2.6 182 12 186 165 -3.9 0 -3.7 -4.2 01/21/2007 20:20:00 3.4 0.5 4.6 2.3 3.2 0.5 4.9 1.9 3.2 0.6 4.6 1.9 202 8 206 165 -3.8 0 -3.5 -4.2 01/21/2007 20:30:00 3.3 0.7 5.3 1.5 3.1 0.7 5.3 1.5 3 0.6 4.6 1.9 199 9 202 165 -3.8 0 -3.7 -4.2 01/21/2007 20:40:00 4 0.5 4.9 2.6 3.8 0.5 4.6 2.6 3.7 0.5 4.9 2.6 196 5 199 165 -3.9 0 -3.7 -4.2 01/21/2007 20:50:00 4.1 0.8 6.5 2.6 3.9 0.8 6.1 2.6 3.8 0.7 6.5 2.6 203 7 201 165 -3.9 0 -3.5 -4.4 01/21/2007 21:00:00 3.5 0.7 5.3 2.3 3.3 0.7 4.9 1.9 3.3 0.7 5.3 1.9 187 11 195 165 -3.6 0 -3.5 -3.7 01/21/2007 21:10:00 3 0.8 4.9 1.1 2.7 0.8 4.9 0.7 2.7 0.7 4.9 1.5 187 13 206 165 -3.7 0 -3.5 -3.9 01/21/2007 21:20:00 3.4 0.9 5.3 1.1 3.3 0.9 4.9 0.7 3 0.9 5.7 1.1 201 15 199 165 -3.7 0 -3.5 -3.9 01/21/2007 21:30:00 3 0.5 4.2 1.9 2.9 0.5 4.2 1.9 2.6 0.5 3.8 1.5 223 8 242 165 -3.6 0 -3.5 -3.9 01/21/2007 21:40:00 2.8 0.7 4.6 1.5 2.7 0.7 4.6 1.5 2.3 0.7 4.6 1.1 223 10 228 165 -3.5 0 -3.3 -3.5 01/21/2007 21:50:00 3.2 0.5 4.2 1.9 3 0.5 4.2 1.9 2.9 0.4 4.2 1.9 191 17 218 165 -3.5 0.1 -3.3 -3.7 01/21/2007 22:00:00 2.6 0.5 3.8 1.5 2.4 0.5 3.4 1.5 2.1 0.5 3.4 0.4 195 12 204 165 -3.9 0 -3.5 -4.2 01/21/2007 22:10:00 2.5 0.4 3.4 1.5 2.3 0.5 3.4 1.1 1.9 0.5 3 0.7 205 7 215 165 -4 0 -3.9 -4.4 01/21/2007 22:20:00 1.7 0.4 2.6 0.7 1.5 0.5 2.6 0.4 0.9 0.5 2.3 0.4 247 36 268 165 -4.1 0 -3.7 -4.4 01/21/2007 22:30:00 1.7 0.3 2.3 1.1 1.6 0.3 2.3 0.7 1.5 0.3 1.9 0.7 307 18 284 165 -4.1 0.2 -3.7 -4.6 01/21/2007 22:40:00 1.1 0.3 1.5 0.4 0.9 0.3 1.5 0.4 0.8 0.4 1.5 0.4 330 0 330 165 -4.6 0.1 -4.4 -4.6 01/21/2007 22:50:00 0.5 0.3 1.5 0.4 0.4 0.2 1.1 0.4 0.5 0.2 1.1 0.4 330 0 330 165 -4.6 0 -4.4 -4.6 01/21/2007 23:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 330 0 165 165 -4 0.3 -3.5 -4.6 01/21/2007 23:10:00 0.4 0 0.7 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 330 0 330 165 -3.8 0.2 -3.5 -4.4 01/21/2007 23:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 330 0 165 165 -4.5 0.1 -4.2 -4.6 01/21/2007 23:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 330 0 165 165 -4.2 0.1 -3.9 -4.6 01/21/2007 23:40:00 1.3 0.4 1.9 0.4 1.1 0.4 1.9 0.4 1.1 0.6 1.9 0.4 177 61 163 165 -3.9 0 -3.7 -4.2 01/21/2007 23:50:00 1.5 0.3 2.3 0.7 1.4 0.3 2.3 0.7 1.1 0.4 1.9 0.4 167 8 165 165 -3.8 0.1 -3.5 -4.2 01/22/2007 00:00:00 2.2 0.3 2.6 1.5 2 0.3 2.6 1.1 1.7 0.3 2.6 1.1 171 7 165 165 -3.7 0 -3.5 -3.9 01/22/2007 00:10:00 2.5 0.3 3 1.9 2.3 0.3 3 1.5 2.1 0.4 3 1.5 179 5 179 165 -3.7 0 -3.5 -3.9 01/22/2007 00:20:00 2.7 0.5 4.2 1.5 2.6 0.5 4.2 1.5 2.3 0.5 3.8 1.1 192 11 177 165 -3.7 0 -3.5 -3.9 01/22/2007 00:30:00 2.6 0.6 4.2 1.1 2.4 0.6 3.8 0.7 2 1 4.2 0.4 189 7 197 165 -3.7 0 -3.5 -3.9 01/22/2007 00:40:00 3.3 0.3 4.6 2.6 3.2 0.4 4.2 2.6 3.2 0.3 4.2 2.3 191 4 195 165 -3.6 0 -3.5 -3.9 01/22/2007 00:50:00 3.5 0.3 4.6 2.6 3.2 0.3 4.2 2.6 3.2 0.2 3.8 2.6 183 8 193 165 -3.7 0 -3.5 -3.9 01/22/2007 01:00:00 3.9 0.5 4.9 3 3.6 0.5 4.6 2.6 3.6 0.4 4.6 2.6 178 4 184 165 -3.7 0 -3.5 -3.9 01/22/2007 01:10:00 4 0.4 4.9 3 3.7 0.4 4.6 2.6 3.6 0.3 4.6 2.6 176 6 165 165 -3.7 0 -3.5 -3.9 01/22/2007 01:20:00 4.1 0.3 4.9 3 3.9 0.3 4.6 3 3.6 0.4 4.6 2.6 177 8 168 165 -3.8 0.1 -3.5 -4.2 01/22/2007 01:30:00 3.2 0.4 4.6 1.9 3 0.4 4.2 1.9 3 0.4 4.2 1.9 186 5 186 165 -3.5 0 -3.3 -3.9 01/22/2007 01:40:00 2.9 0.5 4.2 1.9 2.8 0.5 3.8 1.5 2.8 0.4 4.2 1.9 205 9 207 165 -3.4 0 -3.3 -3.5 01/22/2007 01:50:00 2.4 0.4 3.4 1.5 2.3 0.4 3 1.5 2.3 0.4 3.4 1.5 209 5 204 165 -3.4 0 -3.3 -3.5 01/22/2007 02:00:00 2.5 0.3 3 1.5 2.4 0.3 3.4 1.5 2.1 0.4 3 1.5 223 6 212 165 -3.4 0 -3.3 -3.5 01/22/2007 02:10:00 1.9 0.6 3 0.4 1.7 0.7 3 0.4 1.8 0.7 3 0.4 215 9 254 165 -3.4 0 -3.3 -3.5 01/22/2007 02:20:00 2.5 0.3 3.4 1.9 2.2 0.3 3 1.5 2.3 0.3 3 1.5 188 9 186 165 -3.5 0.1 -3.3 -3.7 01/22/2007 02:30:00 4.1 0.8 5.3 2.3 3.9 0.8 5.3 2.3 3.8 1 5.3 1.9 193 9 186 165 -3.6 0.1 -3.3 -3.9 01/22/2007 02:40:00 3.4 0.8 5.7 1.9 3.2 0.8 5.3 1.5 3.3 0.8 5.3 1.5 169 20 201 165 -3.7 0.2 -3.3 -4.2 01/22/2007 02:50:00 3.7 0.5 4.9 2.6 3.5 0.5 4.6 2.3 3.4 0.6 4.6 1.5 186 12 183 165 -3.8 0.2 -3.3 -4.4 01/22/2007 03:00:00 2.7 0.3 3.4 1.5 2.5 0.3 3 1.5 2.3 0.4 3.4 0.7 191 7 200 165 -3.5 0 -3.3 -3.7 01/22/2007 03:10:00 2.9 0.5 3.8 1.9 2.7 0.5 3.8 1.5 2.8 0.5 3.8 1.9 170 16 165 165 -3.5 0 -3.3 -3.7 01/22/2007 03:20:00 3.7 0.2 4.2 3 3.4 0.2 4.2 3 3.5 0.2 4.2 3 156 15 139 165 -3.6 0 -3.3 -3.7 01/22/2007 03:30:00 4 0.4 5.3 3 3.7 0.4 4.9 2.6 3.6 0.3 4.9 2.6 156 21 167 165 -3.4 0 -3.3 -3.7 01/22/2007 03:40:00 3.5 0.5 4.9 2.6 3.3 0.4 4.6 2.6 3.2 0.4 4.2 2.3 164 13 176 165 -3.4 0 -3 -3.5 01/22/2007 03:50:00 2.7 0.4 4.6 1.9 2.4 0.4 4.2 1.5 2.4 0.4 3.4 1.9 159 13 176 165 -3.7 0.2 -3.3 -4.4 01/22/2007 04:00:00 3.4 0.6 4.6 2.3 3.2 0.6 4.2 1.9 2.9 0.5 3.8 1.9 154 17 104 165 -4 0 -3.7 -4.4 01/22/2007 04:10:00 3.5 0.3 4.2 3 3.2 0.3 3.8 2.6 3.1 0.3 4.2 2.6 161 17 155 165 -3.8 0.1 -3.5 -3.9 01/22/2007 04:20:00 2.7 0.3 3.4 2.3 2.5 0.3 3 1.9 2.4 0.3 3 1.9 175 5 174 165 -3.6 0 -3.3 -3.9 01/22/2007 04:30:00 2.4 0.2 3.4 1.9 2.1 0.2 3 1.5 2.2 0.2 2.6 1.9 174 5 179 165 -3.5 0 -3.3 -3.5 01/22/2007 04:40:00 2.2 0.2 2.6 1.9 1.9 0.2 2.3 1.5 2.1 0.2 2.6 1.5 164 8 174 165 -3.5 0 -3.3 -3.5 01/22/2007 04:50:00 2.4 0.2 3 1.9 2.1 0.2 2.6 1.5 2.2 0.2 2.6 1.5 160 4 158 165 -3.5 0 -3.3 -3.5 01/22/2007 05:00:00 2.9 0.4 3.8 2.3 2.8 0.4 3.4 1.9 2.7 0.6 3.8 1.5 155 9 158 165 -3.5 0 -3.3 -3.5 01/22/2007 05:10:00 3.3 0.2 3.8 2.6 3.1 0.2 3.4 2.3 3.1 0.3 3.8 2.3 154 8 158 165 -3.5 0 -3.3 -3.5 01/22/2007 05:20:00 2.8 0.3 3.4 1.9 2.6 0.3 3.4 1.9 2.5 0.4 3.4 1.5 155 5 157 165 -3.4 0 -3.3 -3.5 01/22/2007 05:30:00 3.2 0.4 3.8 2.3 2.9 0.3 3.8 1.9 3 0.3 3.8 2.3 154 12 159 165 -3.5 0 -3.3 -3.5 01/22/2007 05:40:00 2.6 0.4 3.8 1.5 2.5 0.4 3.4 1.5 2.5 0.4 3.4 1.9 156 8 148 165 -3.8 0 -3.5 -4.2 01/22/2007 05:50:00 2.4 0.4 3.4 1.5 2.3 0.3 3 1.5 2.1 0.5 3 0.7 140 6 148 165 -3.8 0 -3.5 -4.2 01/22/2007 06:00:00 2.4 0.3 3 1.5 2.3 0.3 3 1.5 2.1 0.3 3 1.5 156 9 162 165 -3.6 0 -3.5 -3.9 01/22/2007 06:10:00 2.9 0.4 3.4 1.9 2.7 0.4 3.4 1.5 2.7 0.4 3.4 1.5 153 12 157 165 -3.6 0 -3.5 -3.7 01/22/2007 06:20:00 2.8 0.3 3.4 1.5 2.6 0.3 3 1.5 2.4 0.3 3 1.5 158 8 157 165 -3.5 0 -3.3 -3.7 01/22/2007 06:30:00 2.9 0.2 3.4 2.3 2.6 0.2 3 1.9 2.5 0.2 3 1.9 163 13 151 165 -3.6 0 -3.3 -3.7 01/22/2007 06:40:00 2.6 0.2 3 2.3 2.4 0.2 2.6 1.9 2.4 0.2 2.6 1.5 170 5 160 165 -3.5 0 -3.3 -3.7 01/22/2007 06:50:00 2.2 0.3 3 1.1 1.9 0.4 2.6 0.7 1.6 0.5 2.3 0.4 183 11 195 165 -3.5 0 -3.3 -3.5 01/22/2007 07:00:00 3.6 0.4 4.6 2.3 3.4 0.4 4.6 2.3 3.3 0.4 4.2 2.3 191 6 196 165 -3.2 0.2 -2.8 -3.5 01/22/2007 07:10:00 2.6 0.5 3.4 1.5 2.3 0.5 3.4 1.1 1.9 0.6 3.4 0.4 185 11 179 165 -3.3 0 -3 -3.5 01/22/2007 07:20:00 2.4 0.4 3.4 1.1 2.1 0.4 3 0.7 1.6 0.5 2.6 0.4 184 12 183 165 -3.3 0 -3.3 -3.5 01/22/2007 07:30:00 2 0.6 4.2 0.4 1.8 0.6 3.8 0.4 1.8 0.5 3 0.7 156 19 151 165 -3.5 0.1 -3.3 -3.7 01/22/2007 07:40:00 2.5 0.4 3.8 1.1 2.4 0.4 3.4 1.1 2.5 0.4 3.4 1.1 141 17 165 165 -3.4 0.2 -3 -3.9 01/22/2007 07:50:00 2.4 0.4 3.8 1.5 2.3 0.4 3.4 1.1 2.2 0.4 3 1.1 147 12 170 165 -3.8 0 -3.5 -3.9 01/22/2007 08:00:00 2.4 0.5 3.8 1.1 2.4 0.5 3.8 1.1 2.4 0.5 3.4 1.1 132 11 138 165 -3.9 0 -3.5 -4.2 01/22/2007 08:10:00 3.7 0.3 4.2 3 3.5 0.3 3.8 2.6 3.4 0.4 4.2 2.6 149 12 153 165 -3.8 0.1 -3.5 -4.2 01/22/2007 08:20:00 3.9 0.2 4.6 3.4 3.6 0.2 4.2 3 3.7 0.3 4.2 3 167 12 172 165 -3.5 0 -3.3 -3.5 01/22/2007 08:30:00 3.1 0.3 3.8 2.3 2.8 0.3 3.4 1.9 2.7 0.3 3.8 1.9 169 9 168 165 -3.5 0 -3.3 -3.5 01/22/2007 08:40:00 3.3 0.3 4.2 2.3 3 0.3 3.8 2.3 3 0.4 3.8 2.3 163 12 165 165 -3.4 0.1 -3.3 -3.5 01/22/2007 08:50:00 3.6 0.4 4.9 2.6 3.4 0.4 4.6 2.3 3.5 0.3 4.6 2.6 158 17 172 165 -3.6 0 -3.5 -3.9 01/22/2007 09:00:00 3.2 0.4 4.2 2.3 2.9 0.4 3.8 2.3 2.9 0.3 3.8 2.3 154 19 136 165 -3.8 0 -3.5 -4.2 01/22/2007 09:10:00 2.9 0.4 3.8 2.3 2.7 0.4 3.8 1.9 3 0.4 3.8 1.9 152 12 159 165 -4.2 0 -3.9 -4.4 01/22/2007 09:20:00 1.5 0.5 2.6 0.4 1.2 0.5 2.3 0.4 1.3 0.4 2.6 0.4 164 8 168 165 -4.2 0 -3.9 -4.4 01/22/2007 09:30:00 1.4 0.4 2.3 0.4 1.2 0.4 2.3 0.4 0.9 0.4 1.9 0.4 174 8 174 165 -4.2 0 -3.9 -4.4 01/22/2007 09:40:00 1.2 0.5 2.3 0.4 1.1 0.5 2.3 0.4 0.8 0.5 1.9 0.4 189 21 179 165 -4.1 0 -3.9 -4.4 01/22/2007 09:50:00 1.6 0.4 2.3 0.4 1.5 0.4 2.3 0.4 1.2 0.4 1.9 0.4 221 9 212 165 -4 0.1 -3.5 -4.4 01/22/2007 10:00:00 2.6 0.8 3.8 0.4 2.5 0.8 3.8 0.4 2.1 0.8 3.8 0.4 221 12 213 165 -3.1 0.3 -2.6 -3.7 01/22/2007 10:10:00 3.6 0.5 4.6 2.3 3.5 0.5 4.6 2.3 3.3 0.5 4.6 2.3 205 6 210 165 -2.7 0 -2.6 -3 01/22/2007 10:20:00 4.1 0.8 6.1 2.3 3.9 0.8 5.7 1.9 3.8 0.8 5.3 1.9 194 6 204 165 -2.6 0 -2.6 -2.8 01/22/2007 10:30:00 3.5 0.9 5.3 1.5 3.3 0.8 4.9 1.1 3.3 0.7 4.9 1.5 178 14 185 165 -2.5 0.1 -2.4 -2.8 01/22/2007 10:40:00 3 0.8 5.7 1.1 2.8 0.7 4.9 1.1 2.7 0.7 4.6 0.4 176 16 133 165 -2.2 0 -2.1 -2.6 01/22/2007 10:50:00 3.1 0.9 5.7 1.5 2.8 0.9 4.9 0.7 3 0.8 5.3 1.1 184 17 180 165 -2.2 0 -1.9 -2.8 01/22/2007 11:00:00 5.7 1.3 8 2.6 5.6 1.3 8 2.3 5.3 1.3 8 2.3 211 5 208 165 -2.4 0.1 -2.1 -2.6 01/22/2007 11:10:00 7 0.3 8 6.1 7 0.3 8 6.1 7 0.6 8 4.6 205 3 206 165 -2.3 0 -1.9 -2.6 01/22/2007 11:20:00 6.8 0.4 8 5.7 6.8 0.4 8 5.7 6.5 0.5 7.6 4.9 206 3 207 165 -2.2 0.1 -1.9 -2.6 01/22/2007 11:30:00 6.2 0.5 7.6 4.9 6.3 0.5 7.6 4.9 5.9 0.6 7.6 4.2 211 5 208 165 -2.1 0 -1.9 -2.4 01/22/2007 11:40:00 6.5 0.7 9.1 4.6 6.5 0.8 9.1 4.9 6.2 0.7 8.8 4.2 215 5 212 165 -2 0 -1.9 -2.1 01/22/2007 11:50:00 6.4 0.8 8.8 3.8 6.5 0.8 8.8 3.8 6.1 0.9 8.4 3.8 216 6 207 165 -1.5 0.1 -1.4 -1.9 01/22/2007 12:00:00 5.9 0.6 7.2 3.8 6 0.6 7.2 4.2 5.6 0.7 7.2 3.4 211 5 208 165 -1.8 0.1 -1.4 -2.1 01/22/2007 12:10:00 4.4 0.6 5.7 3 4.4 0.6 5.7 3 4.1 0.6 5.7 2.3 217 6 228 165 -1.7 0.1 -1.4 -2.1 01/22/2007 12:20:00 4 0.5 4.9 2.3 4 0.5 5.3 2.3 3.8 0.5 4.9 2.3 219 5 215 165 -1.4 0 -1.2 -1.4 01/22/2007 12:30:00 3.2 0.5 4.2 1.9 3.2 0.5 4.2 1.9 3 0.5 3.8 1.5 264 27 230 165 -2 0.4 -1.2 -2.8 01/22/2007 12:40:00 4.3 0.5 5.3 3 4.3 0.5 5.3 3 3.1 0.5 4.2 1.9 298 4 301 165 -2.5 0.1 -2.1 -3 01/22/2007 12:50:00 3.5 0.4 4.6 2.6 3.5 0.4 4.6 2.6 2.8 0.7 4.2 1.5 290 5 284 165 -2.4 0.1 -2.1 -3 01/22/2007 13:00:00 3.7 0.5 4.6 2.3 3.6 0.5 4.6 2.3 3.5 0.5 4.6 1.9 282 5 285 165 -3 0.1 -2.6 -3.5 01/22/2007 13:10:00 4.6 0.4 5.7 3.8 4.6 0.4 5.7 3.8 4.8 0.4 5.7 3.8 279 3 278 165 -3.2 0.2 -2.8 -3.7 01/22/2007 13:20:00 5.5 0.5 6.5 4.2 5.5 0.5 6.5 4.2 5 0.8 6.8 2.6 286 6 287 165 -3.1 0 -2.8 -3.5 01/22/2007 13:30:00 5.3 0.5 6.8 4.2 5.3 0.5 6.8 4.2 4.3 1 7.2 2.6 291 4 282 165 -3 0 -2.8 -3.3 01/22/2007 13:40:00 4.6 0.3 5.7 3.8 4.6 0.3 5.7 3.8 3.9 0.5 5.3 2.6 301 11 283 165 -3 0 -2.8 -3.3 01/22/2007 13:50:00 5.6 0.6 6.8 4.2 5.5 0.6 6.8 4.2 4.4 0.7 6.1 3 304 4 302 165 -2.9 0 -2.8 -3 01/22/2007 14:00:00 6.1 0.5 7.2 4.6 6.1 0.5 7.2 4.6 4.5 0.5 5.7 3 300 4 300 165 -3.1 0 -2.8 -3.3 01/22/2007 14:10:00 6 0.5 7.2 4.6 6 0.5 7.2 4.6 4.9 0.8 7.2 3 304 7 293 165 -3.2 0 -3 -3.3 01/22/2007 14:20:00 5.6 0.8 7.6 4.2 5.6 0.8 7.6 4.2 4.7 0.9 6.8 2.6 302 8 299 165 -3.2 0 -3 -3.5 01/22/2007 14:30:00 5.5 0.5 6.8 3.8 5.5 0.5 6.8 3.8 4.3 0.7 6.5 3 297 6 292 165 -3.3 0 -3 -3.5 01/22/2007 14:40:00 5.3 0.4 6.1 4.2 5.3 0.4 6.1 4.2 4 0.5 5.3 2.6 299 4 298 165 -3.4 0 -3.3 -3.5 01/22/2007 14:50:00 5.2 0.5 6.5 4.2 5.1 0.5 6.5 4.2 3.7 0.4 5.3 3 301 4 299 165 -3.3 0 -3 -3.5 01/22/2007 15:00:00 6.2 0.7 7.6 4.2 6.2 0.7 7.6 4.2 4.7 0.6 6.1 3.4 302 3 304 165 -3.4 0 -3.3 -3.5 01/22/2007 15:10:00 5.5 0.6 6.8 4.2 5.5 0.6 6.5 3.8 4.1 0.6 6.1 2.6 299 4 291 165 -3.5 0 -3.3 -3.5 01/22/2007 15:20:00 5.3 0.5 6.5 4.2 5.3 0.5 6.5 3.8 3.8 0.5 5.3 2.6 297 4 298 165 -3 0.2 -2.6 -3.5 01/22/2007 15:30:00 5.4 0.5 6.5 4.2 5.3 0.5 6.5 4.2 3.9 0.4 4.9 2.6 300 3 295 165 -2.8 0.1 -2.6 -3.5 01/22/2007 15:40:00 5.2 0.4 6.1 4.2 5.2 0.4 6.1 3.8 3.8 0.4 4.9 2.3 300 4 303 165 -3.2 0.1 -2.8 -3.7 01/22/2007 15:50:00 6.1 0.8 7.6 4.2 6 0.8 7.2 4.2 4.7 1 6.8 3 304 4 304 165 -3.5 0.1 -3.3 -3.7 01/22/2007 16:00:00 6.7 0.8 8.4 4.9 6.6 0.8 8.4 4.9 4.9 0.7 6.5 3.4 302 4 297 165 -3.7 0 -3.5 -3.9 01/22/2007 16:10:00 6.3 0.6 7.2 4.9 6.2 0.5 7.2 4.9 4.8 0.6 6.5 3.4 304 4 304 165 -3.9 0 -3.5 -4.2 01/22/2007 16:20:00 5.8 0.5 6.8 4.6 5.7 0.5 6.8 4.6 4.7 0.6 6.5 3 306 4 302 165 -3.9 0 -3.7 -4.2 01/22/2007 16:30:00 4.9 0.5 5.7 3.8 4.8 0.5 5.7 3.4 3.5 0.6 5.3 2.3 297 4 307 165 -4.2 0 -3.9 -4.4 01/22/2007 16:40:00 6 0.5 7.2 4.6 5.9 0.5 6.8 4.6 4.5 0.7 6.1 3 303 4 305 165 -4.5 0.2 -4.2 -4.8 01/22/2007 16:50:00 5 0.4 5.7 3.8 5 0.4 5.7 3.8 3.7 0.5 5.3 2.6 299 4 301 165 -4.5 0 -4.4 -4.6 01/22/2007 17:00:00 4.5 0.4 5.3 3.4 4.4 0.4 5.3 3.4 3.5 0.5 4.9 2.3 298 7 292 165 -4.7 0.1 -4.4 -4.8 01/22/2007 17:10:00 3.8 0.3 4.6 3 3.8 0.3 4.6 3 3.2 0.5 4.2 1.9 306 5 318 165 -4.9 0 -4.6 -5.3 01/22/2007 17:20:00 4 0.4 4.9 3 4 0.4 4.9 3 3 0.4 3.8 1.9 301 5 303 165 -5 0 -4.6 -5.3 01/22/2007 17:30:00 4.7 0.5 6.1 3.8 4.7 0.5 6.1 3.4 4 0.6 5.3 2.3 304 8 309 165 -5.3 0.1 -5 -5.7 01/22/2007 17:40:00 5.1 0.5 6.5 4.2 5 0.5 6.5 4.2 4.2 0.6 5.7 2.6 305 8 297 165 -5.3 0.1 -5 -5.7 01/22/2007 17:50:00 4 0.5 5.7 2.6 4 0.5 5.3 2.6 3.5 0.6 4.9 1.9 306 7 302 165 -5.2 0.1 -4.8 -5.5 01/22/2007 18:00:00 4.5 0.8 5.7 2.6 4.5 0.8 5.7 2.3 3.6 0.8 5.7 2.3 303 6 307 165 -5.4 0 -5.3 -5.7 01/22/2007 18:10:00 5 0.5 6.1 3.8 5 0.5 6.1 3.8 4.3 0.7 6.1 3 304 10 319 165 -5.3 0 -5 -5.7 01/22/2007 18:20:00 6.1 0.8 7.6 4.6 6 0.8 7.6 4.6 4.5 1 7.2 2.6 300 5 308 165 -5.4 0 -5 -5.7 01/22/2007 18:30:00 5.8 0.7 7.6 4.6 5.7 0.7 7.6 4.2 4.8 0.5 6.5 3.8 293 8 300 165 -5.4 0.1 -5.3 -5.7 01/22/2007 18:40:00 5.9 0.4 6.8 4.9 5.9 0.4 6.8 4.9 5 0.7 6.8 3.4 292 3 292 165 -5.5 0.1 -5.3 -5.7 01/22/2007 18:50:00 6.8 0.4 7.6 5.7 6.8 0.4 8 5.7 6.4 0.5 7.6 4.9 285 3 282 165 -5.3 0 -5 -5.5 01/22/2007 19:00:00 5.2 1 7.2 3.4 5.2 1 7.2 3 4.5 0.8 6.8 3 307 13 287 165 -5.7 0.3 -5 -6.4 01/22/2007 19:10:00 4 0.9 5.7 1.5 3.9 1 5.7 0.7 3.9 0.8 5.7 2.3 319 10 308 165 -5.5 0.2 -5.3 -6.1 01/22/2007 19:20:00 4.4 0.7 6.1 2.6 4.3 0.7 5.7 2.6 4.3 0.6 6.1 2.3 329 13 314 165 -5.8 0.1 -5.5 -6.1 01/22/2007 19:30:00 4.2 0.9 6.5 2.6 4.1 1 6.5 2.3 4.1 0.8 6.1 2.6 330 7 318 165 -5.8 0 -5.5 -5.9 01/22/2007 19:40:00 2.8 0.5 4.2 1.9 2.4 0.6 4.2 0.7 2.7 0.4 3.8 1.9 345 11 347 165 -5.9 0 -5.7 -6.1 01/22/2007 19:50:00 2.8 0.8 4.2 1.1 2.7 0.9 4.2 1.1 2.4 0.7 4.2 0.7 310 11 304 165 -5.4 0.3 -5 -6.1 01/22/2007 20:00:00 4.3 0.4 5.3 2.6 4.3 0.4 4.9 2.6 3 0.4 4.2 1.9 297 3 296 165 -5.2 0.1 -5 -5.3 01/22/2007 20:10:00 5.1 0.5 6.1 3.8 5.1 0.5 6.1 3.8 3.8 0.4 4.9 3 303 3 303 165 -5.5 0 -5 -5.7 01/22/2007 20:20:00 6.3 0.3 6.8 5.3 6.2 0.3 6.8 5.3 4.3 0.4 5.3 3.4 299 2 298 165 -5.5 0.1 -5 -5.7 01/22/2007 20:30:00 7.5 0.5 9.1 6.5 7.6 0.5 8.8 6.5 5.2 0.5 7.2 3.8 300 2 296 165 -5.4 0 -5 -5.7 01/22/2007 20:40:00 7.3 0.6 8.8 6.1 7.4 0.6 8.8 6.1 5.1 0.6 6.8 3.4 299 3 304 165 -5.3 0 -5 -5.5 01/22/2007 20:50:00 6.5 0.5 8 4.9 6.6 0.5 8 5.3 4.7 0.5 6.5 3.8 298 4 302 165 -5.2 0 -5 -5.3 01/22/2007 21:00:00 6.4 0.8 8 4.9 6.4 0.8 8 4.9 5.5 1 7.6 3 307 6 308 165 -5.2 0 -5 -5.5 01/22/2007 21:10:00 7.1 0.5 8.4 6.1 7.1 0.5 8.4 6.1 6 0.7 8 4.2 309 4 313 165 -5.3 0 -5 -5.5 01/22/2007 21:20:00 7.6 0.6 9.5 6.1 7.6 0.6 9.5 5.7 6 0.6 7.6 4.6 305 3 302 165 -5.3 0 -5.3 -5.5 01/22/2007 21:30:00 7.7 0.5 8.8 6.8 7.8 0.5 8.8 6.8 6.3 0.8 8 4.6 306 3 308 165 -5.5 0 -5.3 -5.7 01/22/2007 21:40:00 7.8 0.5 9.1 6.5 7.9 0.5 9.1 6.5 6.4 0.8 8.4 4.2 307 4 314 165 -5.6 0 -5.5 -5.7 01/22/2007 21:50:00 9 0.5 9.9 6.5 9.1 0.5 10.3 6.5 6.2 0.5 8 4.9 301 3 298 165 -5.5 0 -5.3 -5.7 01/22/2007 22:00:00 8.3 0.5 9.5 6.8 8.4 0.5 9.5 6.8 6 0.6 8 4.6 296 3 297 165 -5.4 0 -5.3 -5.7 01/22/2007 22:10:00 8.1 0.5 9.1 6.8 8.2 0.4 9.1 6.8 5.6 0.5 7.6 4.2 298 3 298 165 -5.7 0 -5.5 -5.7 01/22/2007 22:20:00 8.3 0.4 9.5 7.2 8.4 0.4 9.5 7.2 6.2 0.6 8 4.6 296 2 300 165 -5.5 0 -5.3 -5.7 01/22/2007 22:30:00 8.3 0.6 10.3 6.8 8.3 0.6 10.3 6.8 6 0.7 8.4 4.6 295 4 296 165 -5.8 0.1 -5.5 -5.9 01/22/2007 22:40:00 8.9 0.5 10.3 7.6 8.9 0.5 10.3 7.6 6.7 0.7 8.8 4.6 294 3 294 165 -5.7 0 -5.5 -5.9 01/22/2007 22:50:00 8.8 0.7 10.3 6.8 8.8 0.7 10.3 6.5 7.3 0.8 9.1 4.2 292 4 291 165 -5.6 0 -5.5 -5.7 01/22/2007 23:00:00 8.9 0.5 9.9 7.2 8.9 0.5 10.3 7.2 6.7 1 9.9 4.9 295 5 300 165 -5.5 0 -5.3 -5.7 01/22/2007 23:10:00 8.3 0.5 9.5 6.1 8.4 0.5 9.5 6.5 5.9 0.6 8 4.6 298 4 300 165 -5.5 0 -5.3 -5.7 01/22/2007 23:20:00 8.9 0.5 10.3 8 9 0.5 10.3 7.6 6.3 0.6 8.8 4.9 300 4 298 165 -5.5 0 -5.3 -5.7 01/22/2007 23:30:00 8.9 0.5 10.3 7.6 9 0.5 10.3 7.6 6.2 0.6 8 4.9 298 4 297 165 -5.5 0 -5.5 -5.7 01/22/2007 23:40:00 8.8 0.5 9.9 6.8 8.8 0.5 10.7 6.8 6.4 0.7 8.8 4.6 297 5 295 165 -5.6 0 -5.5 -5.7 01/22/2007 23:50:00 8.6 0.7 10.3 6.5 8.7 0.7 10.3 6.1 6.3 0.7 8 4.6 297 6 294 165 -5.5 0 -5.5 -5.7 01/23/2007 00:00:00 8 0.9 9.9 5.7 8.1 0.9 9.9 5.7 6.2 0.8 9.1 4.6 297 7 295 165 -5.6 0 -5.5 -5.7 01/23/2007 00:10:00 6.5 0.5 8 4.9 6.5 0.6 8.4 4.9 5.5 0.8 7.6 3.8 296 8 308 165 -5.6 0 -5.5 -5.7 01/23/2007 00:20:00 6.5 0.7 8.4 4.9 6.6 0.8 8.8 4.9 5.8 1 8.4 3.8 297 9 286 165 -5.5 0 -5.5 -5.7 01/23/2007 00:30:00 6.4 0.6 8 4.2 6.4 0.6 8.4 4.6 5.2 0.7 7.2 3.8 298 8 313 165 -5.6 0 -5.5 -5.7 01/23/2007 00:40:00 6.6 0.5 8 4.9 6.7 0.6 8 4.6 5.2 0.7 7.6 3.4 298 7 300 165 -5.6 0 -5.5 -5.7 01/23/2007 00:50:00 6.5 0.7 8 3.8 6.5 0.7 8 4.2 5.3 0.7 7.2 3.8 301 8 300 165 -5.5 0 -5.3 -5.7 01/23/2007 01:00:00 6.3 0.6 8 4.6 6.3 0.6 8 4.9 5.2 0.8 7.6 3.8 299 9 301 165 -5.6 0 -5.5 -5.7 01/23/2007 01:10:00 5.8 0.5 7.2 4.6 5.8 0.5 6.8 4.2 5.1 0.8 7.2 3.4 296 8 295 165 -5.6 0 -5.5 -5.7 01/23/2007 01:20:00 5.6 0.8 8 3.4 5.6 0.8 8 3.4 4.5 0.8 7.2 2.3 300 9 302 165 -5.6 0.1 -5.5 -5.9 01/23/2007 01:30:00 5.7 0.6 7.2 3.8 5.8 0.6 8 4.2 4.9 0.7 6.8 3 299 11 305 165 -5.8 0 -5.7 -5.9 01/23/2007 01:40:00 6.1 0.6 7.6 4.2 6.1 0.6 7.6 4.6 5.5 0.9 8 3 294 10 292 165 -5.8 0 -5.5 -5.9 01/23/2007 01:50:00 6.3 0.8 8.4 4.2 6.3 0.8 8.4 3.8 5.8 1 8.8 3.8 296 12 288 165 -5.8 0 -5.5 -6.1 01/23/2007 02:00:00 6.1 0.7 8 3.8 6.1 0.7 8.4 4.2 5.4 0.7 8 3.4 310 9 307 165 -5.9 0 -5.7 -6.1 01/23/2007 02:10:00 5.7 0.8 8.4 3.8 5.7 0.8 8 3.4 5.3 1 8 3 316 13 318 165 -6 0 -5.7 -6.4 01/23/2007 02:20:00 5.5 0.8 7.2 3.8 5.4 0.8 7.2 3.8 5.5 0.9 7.2 3.4 323 8 332 165 -5.6 0.1 -5.3 -6.1 01/23/2007 02:30:00 6.2 1.2 9.1 3.4 6.1 1.2 8.8 3.4 5.8 1.1 8.4 3.8 334 9 336 165 -5.6 0 -5.5 -5.7 01/23/2007 02:40:00 5.9 1.4 9.1 3 5.9 1.5 9.5 3 5.6 1.6 9.5 2.3 322 15 331 165 -5.5 0 -5.3 -5.7 01/23/2007 02:50:00 4.6 0.8 6.8 3 4.6 0.8 6.8 2.6 4.3 0.9 6.5 1.9 320 11 301 165 -5.6 0 -5.5 -5.7 01/23/2007 03:00:00 4.8 0.8 7.2 3 4.8 0.9 7.6 2.6 4.2 0.9 7.2 2.3 318 16 336 165 -5.8 0 -5.5 -5.9 01/23/2007 03:10:00 5.3 0.7 7.6 3.4 5.3 0.7 7.6 3.4 4.7 0.9 7.6 3 306 16 319 165 -5.8 0 -5.5 -5.9 01/23/2007 03:20:00 5.3 0.8 7.2 3.4 5.3 0.8 7.2 3.4 4.8 0.9 7.2 2.6 304 11 316 165 -5.8 0 -5.5 -5.9 01/23/2007 03:30:00 6 0.8 8 3.8 6.1 0.9 8.4 3.8 5.2 1 8.4 2.6 300 12 309 165 -5.8 0.1 -5.5 -5.9 01/23/2007 03:40:00 5.5 0.9 7.2 3.8 5.5 0.9 7.2 3.8 4.9 0.7 6.8 3 303 14 291 165 -5.9 0.1 -5.5 -6.1 01/23/2007 03:50:00 6.3 0.8 8.4 3.8 6.3 0.9 8.8 4.2 5.2 0.9 7.2 3.4 297 11 290 165 -6 0 -5.7 -6.4 01/23/2007 04:00:00 6.6 0.8 8.8 3.8 6.6 0.8 9.1 3.8 5.6 0.9 8.4 3 295 9 305 165 -6 0 -5.7 -6.4 01/23/2007 04:10:00 6.8 1.1 9.5 3.8 6.8 1.1 9.1 4.6 6.1 1.3 9.5 3.8 305 16 322 165 -5.9 0 -5.5 -6.1 01/23/2007 04:20:00 6.1 0.6 7.6 4.2 6.1 0.6 7.6 3.8 5.1 0.7 7.2 3.4 301 10 300 165 -5.8 0 -5.5 -6.1 01/23/2007 04:30:00 5.3 0.9 8.8 3 5.3 0.9 8.4 3.4 5.1 0.9 8.4 1.9 322 13 344 165 -5.8 0.2 -5.5 -6.1 01/23/2007 04:40:00 6 1.6 10.7 3 5.9 1.6 10.3 3.4 5.9 1.7 10.7 3 329 13 347 165 -5.4 0.2 -5 -5.7 01/23/2007 04:50:00 7.1 1.7 10.3 2.6 7 1.7 11.1 2.6 7.1 1.7 11.1 3.4 329 11 342 165 -5.3 0.1 -5 -5.7 01/23/2007 05:00:00 6.4 1.1 9.5 3 6.4 1.1 9.5 3.8 6.3 1.1 9.1 3.4 331 10 331 165 -5.3 0 -5 -5.7 01/23/2007 05:10:00 7 1 9.5 4.9 7 1 9.9 4.9 6.9 1.1 9.5 4.6 329 10 336 165 -5.3 0.1 -5 -5.5 01/23/2007 05:20:00 5.7 1.1 8.4 2.6 5.7 1.1 8.4 2.6 5.5 1.3 9.1 2.3 321 19 339 165 -5.4 0 -5.3 -5.7 01/23/2007 05:30:00 5 0.8 8.4 2.3 5 0.9 8.4 2.6 4.6 0.8 8 3 313 17 286 165 -5.5 0.2 -5 -5.7 01/23/2007 05:40:00 5.3 0.7 6.8 3 5.2 0.7 6.8 3 5.1 0.8 6.8 3 322 10 307 165 -5.9 0 -5.7 -6.1 01/23/2007 05:50:00 4.8 0.7 6.8 2.6 4.7 0.8 6.5 1.9 4.6 0.8 6.8 2.6 321 13 323 165 -5.8 0 -5.5 -5.9 01/23/2007 06:00:00 5 0.7 7.6 3 5 0.7 7.2 3.8 4.7 0.9 7.2 2.6 323 15 338 165 -5.8 0.1 -5.5 -6.1 01/23/2007 06:10:00 5.8 0.9 8.4 3.8 5.8 0.9 8.4 3.4 5.2 0.9 8 3.4 310 12 287 165 -5.8 0.1 -5.5 -6.1 01/23/2007 06:20:00 5.8 0.9 8 1.9 5.9 0.9 8 1.5 5.1 1 7.6 2.6 307 10 314 165 -5.6 0.2 -5.3 -5.9 01/23/2007 06:30:00 6.7 0.8 9.5 4.6 6.7 0.8 9.9 4.9 5.8 1.1 9.5 3.8 302 10 292 165 -5.7 0 -5.5 -5.7 01/23/2007 06:40:00 8.5 0.8 10.3 5.7 8.5 0.9 10.3 5.7 6.6 1 9.9 4.2 302 7 302 165 -5.8 0 -5.5 -5.7 01/23/2007 06:50:00 9.8 1 12.2 6.8 9.8 0.9 11.8 6.8 7.5 1.1 11.1 5.7 301 8 300 165 -5.8 0.1 -5.5 -5.9 01/23/2007 07:00:00 9.9 0.9 13 6.8 9.8 0.9 12.6 6.8 8.7 1.2 12.2 5.7 308 5 313 165 -5.9 0 -5.7 -6.1 01/23/2007 07:10:00 10 0.6 11.5 8.4 9.9 0.6 11.5 8.4 8.8 1 12.6 6.5 307 5 302 165 -6 0 -5.7 -6.1 01/23/2007 07:20:00 9.9 0.6 13 8.4 9.9 0.6 13.3 8 8.7 1 10.7 6.5 308 5 312 165 -6 0 -5.7 -6.1 01/23/2007 07:30:00 10.1 0.7 12.2 8 10 0.7 11.8 8 9.4 0.8 11.1 6.8 310 6 306 165 -6 0 -5.7 -6.1 01/23/2007 07:40:00 10 0.5 11.8 8.4 9.9 0.5 11.1 8.4 9.7 0.7 11.5 8 313 4 315 165 -6 0 -5.7 -6.1 01/23/2007 07:50:00 9.2 0.8 11.5 7.2 9.1 0.8 11.5 7.2 8.9 0.8 10.7 7.2 314 5 312 165 -6 0 -5.7 -6.4 01/23/2007 08:00:00 9.7 0.5 11.8 8.4 9.6 0.6 11.8 8.4 9.4 0.6 11.1 7.2 313 5 302 165 -5.9 0 -5.7 -6.1 01/23/2007 08:10:00 10 0.6 11.8 8.4 9.9 0.6 11.5 8 9.7 0.7 11.5 7.6 313 4 310 165 -5.8 0 -5.7 -6.1 01/23/2007 08:20:00 9.5 0.8 11.8 7.2 9.4 0.8 11.5 7.2 9.2 0.9 11.1 6.8 313 4 313 165 -5.9 0 -5.7 -6.1 01/23/2007 08:30:00 9.3 0.7 11.1 7.2 9.2 0.7 11.1 7.2 8.8 0.8 10.7 6.5 312 6 301 165 -5.9 0 -5.7 -6.1 01/23/2007 08:40:00 9.3 1 13 6.8 9.3 1 12.6 6.8 9.1 1 13 6.5 314 6 310 165 -5.8 0.1 -5.5 -5.9 01/23/2007 08:50:00 8.8 0.7 10.7 6.8 8.7 0.7 10.7 6.8 8.7 0.8 10.7 6.5 317 6 307 165 -5.9 0 -5.7 -6.1 01/23/2007 09:00:00 8.6 0.6 10.7 6.1 8.4 0.6 10.7 6.5 8.6 0.7 11.8 6.1 319 5 316 165 -5.9 0 -5.7 -5.9 01/23/2007 09:10:00 8.3 0.9 10.3 6.1 8.2 0.8 10.3 6.5 8.3 1 10.7 6.1 317 5 324 165 -6 0 -5.7 -6.1 01/23/2007 09:20:00 8.7 0.6 10.3 7.2 8.6 0.6 10.3 6.8 8.7 0.8 10.7 6.8 316 5 305 165 -6.2 0 -5.9 -6.4 01/23/2007 09:30:00 7.6 0.6 8.8 5.3 7.5 0.6 9.1 5.7 7.6 0.7 8.8 5.7 322 8 320 165 -6.3 0.1 -6.1 -6.6 01/23/2007 09:40:00 7.4 0.6 8.8 5.3 7.3 0.6 8.4 4.9 7.4 0.6 8.4 5.7 321 5 318 165 -6.4 0 -6.1 -6.6 01/23/2007 09:50:00 6.5 0.5 7.6 4.9 6.4 0.5 7.6 4.9 6.5 0.5 8 5.3 322 6 332 165 -6 0.2 -5.7 -6.6 01/23/2007 10:00:00 6.1 0.8 8 4.2 6.1 0.8 7.6 4.2 6 0.7 7.6 4.6 317 6 311 165 -5.8 0 -5.7 -5.9 01/23/2007 10:10:00 5.3 0.5 6.5 4.2 5.2 0.5 6.5 4.2 5.3 0.5 6.8 4.2 319 6 316 165 -5.5 0.2 -5 -5.9 01/23/2007 10:20:00 5.5 0.5 6.5 3.8 5.4 0.5 6.5 3.8 5.5 0.5 6.8 4.2 323 6 315 165 -5 0.1 -4.6 -5.5 01/23/2007 10:30:00 4.5 0.6 6.1 2.3 4.3 0.6 5.7 2.3 4.5 0.7 6.1 2.3 321 10 335 165 -4.9 0.2 -4.6 -5.3 01/23/2007 10:40:00 4.5 0.8 6.5 2.6 4.3 0.8 6.5 2.6 4.4 0.9 6.5 2.3 317 9 315 165 -5.4 0 -5 -5.7 01/23/2007 10:50:00 4.6 0.5 6.1 3.4 4.5 0.5 5.7 3.4 4.4 0.5 5.7 3 312 7 316 165 -5.4 0 -5.3 -5.7 01/23/2007 11:00:00 5.1 0.6 6.1 3.4 5 0.6 6.5 3.4 4.6 0.6 6.1 3 311 6 303 165 -5.4 0 -5 -5.7 01/23/2007 11:10:00 5.3 0.4 6.5 4.2 5.2 0.4 6.1 4.2 5.2 0.5 6.5 3.8 316 5 322 165 -5 0 -4.8 -5.5 01/23/2007 11:20:00 5.6 0.8 7.6 3.8 5.6 0.8 7.6 3.8 5.4 0.7 7.6 3.8 314 8 322 165 -5.3 0.1 -5 -5.5 01/23/2007 11:30:00 5.9 0.6 7.2 4.6 5.8 0.6 7.2 4.6 5.6 0.6 7.2 3.8 312 5 304 165 -5.4 0 -5.3 -5.7 01/23/2007 11:40:00 5.7 0.7 8 4.2 5.7 0.7 8 4.6 5.4 0.8 7.2 3.8 314 8 307 165 -5.4 0 -5.3 -5.7 01/23/2007 11:50:00 6.1 0.8 8.4 4.6 6.1 0.7 8 4.6 6 0.7 8 4.2 322 8 318 165 -5.3 0.1 -4.6 -5.5 01/23/2007 12:00:00 6 0.8 8 3.8 6 0.8 8 4.2 6.1 0.9 8.4 3.8 321 6 313 165 -4.5 0.2 -4.2 -5 01/23/2007 12:10:00 5.3 0.5 6.8 3.8 5.2 0.5 6.5 3.8 5.1 0.5 6.8 3.4 318 9 305 165 -4.5 0.2 -4.2 -5 01/23/2007 12:20:00 6 0.6 7.6 4.6 5.9 0.6 7.6 4.6 5.7 0.6 7.2 4.2 313 6 322 165 -4.3 0 -4.2 -4.6 01/23/2007 12:30:00 7.7 1.2 10.3 4.6 7.7 1.2 10.3 4.6 7.2 1.1 9.5 4.2 311 7 313 165 -4.7 0.1 -4.4 -5 01/23/2007 12:40:00 8.1 0.7 9.5 6.8 8 0.7 9.9 6.5 7.8 0.8 10.3 6.1 314 5 313 165 -4.9 0 -4.6 -5.3 01/23/2007 12:50:00 7 0.8 9.1 5.7 6.9 0.7 8.8 5.3 7 0.8 9.1 5.3 319 4 319 165 -4.7 0 -4.4 -4.8 01/23/2007 13:00:00 5 0.7 6.8 3.4 4.9 0.7 6.8 3.4 4.8 0.8 6.8 3 323 8 321 165 -4 0.3 -3.3 -4.6 01/23/2007 13:10:00 5.2 0.6 6.5 2.6 5.1 0.6 6.5 2.6 5 0.7 6.8 3 324 9 315 165 -3.8 0.1 -3.5 -4.4 01/23/2007 13:20:00 5.5 0.8 7.6 3.8 5.5 0.8 7.6 3.4 5.5 0.9 8 3.4 322 9 327 165 -3.9 0.1 -3.5 -4.6 01/23/2007 13:30:00 4.3 0.8 6.1 2.3 4.3 0.8 6.1 2.3 3.9 0.8 5.7 2.3 315 12 294 165 -4 0.2 -3.5 -4.4 01/23/2007 13:40:00 5.2 1 8 1.9 5.2 1.1 8.8 2.3 4.6 1 7.6 1.9 313 11 305 165 -4.1 0.3 -3.5 -4.6 01/23/2007 13:50:00 5.4 0.9 8 3 5.5 0.9 8 3.4 4.7 1 8.4 2.6 311 11 316 165 -4.4 0.3 -3.5 -4.8 01/23/2007 14:00:00 4 0.8 6.1 1.9 4 0.8 5.7 1.9 3.5 1 6.1 1.5 318 11 340 165 -3.8 0.2 -3.3 -4.2 01/23/2007 14:10:00 4.9 1 7.2 3 4.9 1 7.2 2.6 4.1 0.9 6.5 2.3 305 12 307 165 -4.1 0.4 -3.3 -4.6 01/23/2007 14:20:00 5.6 1 8 3.4 5.7 1 8 3.8 4.7 1 7.2 2.6 301 11 304 165 -4.7 0.1 -4.4 -5 01/23/2007 14:30:00 4.9 0.9 7.2 3 5 1 7.6 3 4.2 0.9 6.5 2.3 306 13 310 165 -4.7 0 -4.4 -4.8 01/23/2007 14:40:00 6.6 1.7 11.1 3 6.7 1.7 10.7 3 5.4 1.3 9.5 2.6 302 9 290 165 -4.7 0.3 -4.2 -5.3 01/23/2007 14:50:00 4.8 0.8 6.5 2.6 4.9 0.9 6.8 2.6 4.1 0.9 6.1 1.1 306 12 303 165 -4.9 0.3 -4.4 -5.7 01/23/2007 15:00:00 5.1 1 7.2 1.9 5.1 1 7.2 1.5 4.3 1 6.5 1.9 305 15 332 165 -4.5 0.2 -4.2 -4.8 01/23/2007 15:10:00 4.6 1 7.2 1.9 4.6 1.1 7.6 1.9 3.6 1 6.5 1.1 297 15 292 165 -4.8 0.1 -4.4 -5.3 01/23/2007 15:20:00 3.9 1.3 8.4 0.7 4 1.2 8.4 1.1 3.2 1.2 6.1 0.7 294 17 297 165 -4.9 0.2 -4.4 -5.5 01/23/2007 15:30:00 6.5 1.1 9.1 3.8 6.5 1.2 9.1 3.8 5.5 1.1 9.1 3 297 12 300 165 -5.6 0.2 -5.3 -6.4 01/23/2007 15:40:00 7 1.2 9.9 4.2 7 1.2 9.9 4.2 5.8 1.1 9.1 3.4 297 9 294 165 -5.9 0.2 -5.7 -6.6 01/23/2007 15:50:00 7.3 1.3 11.1 4.6 7.3 1.3 11.5 4.6 6.1 1.2 9.9 3.4 302 9 293 165 -5.9 0 -5.7 -6.1 01/23/2007 16:00:00 7.1 1.5 10.7 4.2 7.1 1.5 10.7 4.6 5.8 1.3 8.8 3.4 303 10 301 165 -6 0 -5.7 -6.1 01/23/2007 16:10:00 7.9 1.1 10.7 4.6 8 1.1 10.7 4.6 6.4 1.1 10.7 3.8 301 8 295 165 -6.1 0 -5.9 -6.4 01/23/2007 16:20:00 8.3 1 11.1 5.3 8.4 1 10.7 5.7 6.6 1 9.5 4.2 300 9 295 165 -6.2 0.1 -5.9 -6.6 01/23/2007 16:30:00 9.7 0.8 12.2 7.6 9.7 0.8 12.2 7.6 8 1 10.7 5.7 303 8 294 165 -6.5 0 -6.4 -6.6 01/23/2007 16:40:00 9.8 1.2 12.6 5.7 9.8 1.1 13 5.7 9 1.3 11.8 5.3 307 8 310 165 -6.6 0 -6.4 -6.8 01/23/2007 16:50:00 9.6 0.6 11.1 7.6 9.6 0.6 11.1 8 8.2 1 10.3 6.1 305 7 304 165 -6.8 0.1 -6.6 -7 01/23/2007 17:00:00 10.2 1 12.6 8 10.2 1 12.6 8 8.6 0.8 11.1 6.5 304 7 302 165 -7.1 0 -6.8 -7.4 01/23/2007 17:10:00 9.2 1 11.1 6.5 9.2 0.9 11.1 6.5 8.3 1.1 11.1 5.3 309 8 301 165 -7.3 0.1 -7 -7.4 01/23/2007 17:20:00 9.9 0.8 12.2 7.6 9.9 0.8 12.2 7.6 8 1 11.1 5.7 303 7 300 165 -7.5 0 -7.2 -7.6 01/23/2007 17:30:00 9.9 0.9 12.2 7.6 9.9 0.9 12.2 7.6 9 1.3 12.6 5.7 305 9 301 165 -7.6 0 -7.4 -7.9 01/23/2007 17:40:00 10 1.3 13 5.7 9.9 1.2 12.6 6.1 8.9 1.6 13 5.7 306 10 317 165 -7.7 0 -7.4 -8.1 01/23/2007 17:50:00 11.5 1 14.1 9.1 11.4 1 14.1 9.1 11 1 13 8 313 6 304 165 -7.8 0 -7.6 -8.1 01/23/2007 18:00:00 10.9 1.1 13 8 10.8 1 13 7.6 10.4 1 13.7 7.2 311 6 307 165 -8 0.1 -7.6 -8.1 01/23/2007 18:10:00 12 1.5 14.9 8.4 11.9 1.4 14.5 8.4 11.5 1.5 14.9 7.6 312 6 309 165 -8 0 -7.6 -8.3 01/23/2007 18:20:00 11.8 1.2 14.5 7.6 11.6 1.1 14.1 8.4 11.3 1.2 14.5 8 313 6 318 165 -8.1 0 -7.9 -8.3 01/23/2007 18:30:00 12.3 1 15.3 9.5 12.1 1 14.9 9.5 11.6 1.2 14.9 8.4 309 6 310 165 -8.2 0 -8.1 -8.3 01/23/2007 18:40:00 13.5 1.1 16.4 10.7 13.4 1 16.1 10.7 11.7 1.5 14.9 7.6 307 5 310 165 -8.1 0 -8.1 -8.3 01/23/2007 18:50:00 13.9 1 16.4 11.5 13.8 1 16.4 11.5 12.2 1.5 15.3 8 307 7 307 165 -8.1 0 -8.1 -8.3 01/23/2007 19:00:00 13.9 1.1 16.1 11.1 13.7 1.1 16.1 10.7 12 1.3 14.5 8 306 6 307 165 -8.2 0 -8.1 -8.5 01/23/2007 19:10:00 12.6 0.8 14.5 9.9 12.5 0.8 14.9 10.3 10.7 1.1 14.1 8 306 6 308 165 -8.4 0 -8.3 -8.5 01/23/2007 19:20:00 12.4 0.8 14.5 9.5 12.2 0.7 14.5 9.5 11.7 0.8 14.1 9.5 311 4 311 165 -8.4 0 -8.3 -8.5 01/23/2007 19:30:00 12.3 1 14.5 8.8 12.1 0.9 14.1 9.1 11.7 1.2 14.5 8.8 312 5 310 165 -8.4 0 -8.3 -8.7 01/23/2007 19:40:00 10.8 0.9 13 8.8 10.7 0.8 13 8.8 10.2 1.2 13.3 6.5 310 7 310 165 -8.3 0 -8.1 -8.5 01/23/2007 19:50:00 11.1 1 13.7 8.8 11.1 1 14.1 9.1 9.2 1.1 12.2 6.5 303 8 301 165 -8.4 0 -8.1 -8.7 01/23/2007 20:00:00 11 1 13 8.4 10.9 0.9 13 8.4 8.8 1.2 11.5 6.1 301 9 296 165 -8.3 0 -8.1 -8.5 01/23/2007 20:10:00 11.3 1.5 14.9 7.2 11.3 1.5 14.9 7.6 8.3 1.5 13.3 5.3 294 7 296 165 -8.2 0.1 -7.9 -8.5 01/23/2007 20:20:00 12.5 1 14.9 9.5 12.4 1 14.5 9.5 9.8 1.3 13 6.5 290 5 294 165 -8 0.1 -7.6 -8.1 01/23/2007 20:30:00 12.7 1.2 15.3 9.5 12.5 1.3 15.6 9.5 9.3 1.7 13.3 6.5 292 6 288 165 -8 0 -7.9 -8.3 01/23/2007 20:40:00 12 1 14.1 9.5 11.9 0.9 13.7 9.1 9.3 1.5 13 6.5 290 8 286 165 -8.1 0 -7.6 -8.3 01/23/2007 20:50:00 13.2 1 15.6 11.1 13.1 1 15.3 11.1 9.8 1.5 13.7 6.8 293 7 292 165 -8.1 0 -7.9 -8.5 01/23/2007 21:00:00 13.7 0.8 15.6 11.5 13.7 0.7 15.3 11.5 9.5 1.1 13.7 7.2 294 7 292 165 -8.2 0 -8.1 -8.5 01/23/2007 21:10:00 13.7 0.9 16.1 11.1 13.7 0.9 16.4 11.1 10.7 1.7 15.3 7.6 290 8 292 165 -8.2 0 -8.1 -8.5 01/23/2007 21:20:00 14.3 1 16.8 11.8 14.3 1 16.8 11.8 12.8 1.5 16.1 9.1 285 6 285 165 -8.1 0 -7.9 -8.3 01/23/2007 21:30:00 11.9 1.5 15.6 9.1 11.8 1.5 15.6 9.1 9.9 1.7 14.9 5.7 288 8 288 165 -8 0 -7.9 -8.3 01/23/2007 21:40:00 10.6 1.2 14.9 8.4 10.5 1.2 14.5 8.4 9.2 1.5 14.5 5.7 286 10 283 165 -8.2 0 -8.1 -8.3 01/23/2007 21:50:00 12.5 1.1 15.6 9.9 12.3 1 15.3 9.5 10.7 1.4 15.3 7.2 284 10 257 165 -8.1 0.1 -7.9 -8.3 01/23/2007 22:00:00 12.9 0.8 14.5 9.5 12.8 0.8 14.5 10.3 12 1.3 14.5 8 282 6 284 165 -8.1 0 -7.9 -8.3 01/23/2007 22:10:00 12.6 1.1 15.3 9.1 12.6 1.1 14.9 9.1 11.1 1.7 14.1 7.2 284 9 289 165 -8.2 0 -7.9 -8.5 01/23/2007 22:20:00 13.7 1 16.1 10.7 13.6 1 15.6 10.7 10.5 1.3 14.1 7.6 289 9 294 165 -8.3 0 -8.1 -8.5 01/23/2007 22:30:00 12 1.5 15.6 8.4 11.9 1.5 15.6 8.4 9.3 1.5 14.5 6.5 290 13 287 165 -8.4 0.1 -8.1 -8.5 01/23/2007 22:40:00 12.3 1.7 15.6 8.8 12.4 1.7 16.1 8.8 10 1.4 13.3 6.1 297 13 274 165 -8.7 0 -8.3 -8.9 01/23/2007 22:50:00 15.9 1.7 19.5 11.8 15.8 1.7 19.1 11.8 13.7 2.6 19.5 8.8 304 9 308 165 -8.6 0.1 -8.5 -8.9 01/23/2007 23:00:00 18.1 1.2 20.6 15.3 18.1 1.2 20.6 15.3 16.8 1.4 19.9 13 307 6 309 165 -8.9 0 -8.5 -9.1 01/23/2007 23:10:00 18.3 1.3 21.8 14.9 18.3 1.2 21.8 14.9 17 1.3 21 13 307 6 302 165 -9 0.1 -8.7 -9.3 01/23/2007 23:20:00 18.3 1.3 21.4 14.9 18.2 1.2 21.8 15.3 16.4 1.6 20.2 11.5 304 8 303 165 -9 0 -8.9 -9.3 01/23/2007 23:30:00 17.5 1.4 20.6 13.7 17.5 1.4 20.6 14.1 15.9 1.5 20.2 11.8 304 9 306 165 -9.1 0.1 -8.9 -9.3 01/23/2007 23:40:00 17.4 1.4 21 13.3 17.3 1.4 21.4 13.7 14.9 1.8 19.5 10.3 300 12 291 165 -9.3 0.1 -9.1 -9.7 01/23/2007 23:50:00 18.8 1.6 22.6 14.1 18.7 1.6 22.6 13.7 15.7 1.7 21 11.5 298 12 308 165 -9.5 0 -9.3 -9.7 01/24/2007 00:00:00 18.8 1.5 22.1 14.9 18.7 1.5 21.8 15.3 16.8 1.7 21.8 13 301 12 282 165 -9.7 0.1 -9.3 -10 01/24/2007 00:10:00 18.2 1.4 21.8 14.9 18.2 1.3 21.8 14.5 17.1 1.6 20.6 13.3 304 10 311 165 -10 0 -9.7 -10.2 01/24/2007 00:20:00 16.8 1.8 21 12.6 16.7 1.8 20.6 12.6 15.6 1.7 18.7 10.7 305 10 302 165 -10.1 0 -9.7 -10.2 01/24/2007 00:30:00 13.1 1.8 17.9 8.8 13 1.8 17.6 8.8 11 1.7 15.6 6.5 301 12 296 165 -10.2 0 -10 -10.2 01/24/2007 00:40:00 12.4 1.4 16.1 9.1 12.4 1.4 16.1 8.8 11.4 1.5 14.5 7.6 306 10 303 165 -10.4 0 -10.2 -10.8 01/24/2007 00:50:00 10.9 2.3 15.6 6.1 10.9 2.3 15.3 6.1 10 2.5 14.9 5.3 308 11 307 165 -10.7 0.1 -10.6 -11 01/24/2007 01:00:00 8.9 1.2 12.2 6.1 8.9 1.2 12.2 5.3 7.7 1.3 11.1 3.8 303 11 307 165 -11.1 0.1 -11 -11.4 01/24/2007 01:10:00 8.5 1.3 12.6 4.9 8.5 1.3 12.2 5.3 7.5 1.5 11.1 3 304 14 307 165 -11.3 0 -11 -11.4 01/24/2007 01:20:00 8.8 2 13 3.4 8.7 2 12.6 3.8 7 1.8 11.5 1.5 290 20 288 165 -11.2 0.1 -11 -11.4 01/24/2007 01:30:00 6.1 2.8 11.1 0.4 6 2.7 10.3 0.4 4.6 2.5 9.9 0.4 270 32 284 165 -11.2 0.2 -10.8 -11.4 01/24/2007 01:40:00 9.1 2.1 13.3 2.6 8.9 2 12.6 3 7.2 2 11.1 2.3 279 17 284 165 -10.5 0.2 -10 -11.2 01/24/2007 01:50:00 7.4 2.4 13 1.1 7.2 2.4 13 1.1 5.8 1.9 10.7 1.1 277 35 281 165 -10.3 0 -10 -10.8 01/24/2007 02:00:00 7 2.9 13 0.4 6.8 2.9 12.2 0.4 5.5 2.6 12.2 0.4 293 58 290 165 -10.5 0 -10.2 -10.8 01/24/2007 02:10:00 10.9 1.6 14.9 6.1 10.6 1.6 14.5 6.5 9.1 1.8 15.6 5.7 282 15 273 165 -10.4 0 -10.2 -10.8 01/24/2007 02:20:00 12.5 1.5 15.6 7.6 12.2 1.3 15.3 7.6 11 1.7 14.9 7.2 277 11 280 165 -10.3 0.1 -10 -10.6 01/24/2007 02:30:00 11 1.3 14.5 8 10.6 1.2 14.5 7.2 8.5 1.7 13.3 3.4 281 13 282 165 -10.4 0.1 -10.2 -10.8 01/24/2007 02:40:00 8.4 1.9 13.3 3.4 8.3 1.8 13 4.2 6.9 1.9 13 1.9 286 17 278 165 -10.3 0.1 -10 -10.6 01/24/2007 02:50:00 12.1 2.5 16.8 5.7 11.9 2.5 16.4 6.1 9.8 2.2 16.4 4.2 292 14 302 165 -10.2 0 -10 -10.4 01/24/2007 03:00:00 13.9 1.3 17.2 10.3 13.8 1.3 17.2 10.3 11.2 1.6 15.6 8 292 16 302 165 -10.2 0 -10 -10.2 01/24/2007 03:10:00 14.5 1.6 19.9 9.9 14.2 1.6 19.9 9.9 11.6 1.8 17.9 8 283 13 274 165 -10.3 0 -10 -10.6 01/24/2007 03:20:00 17 1.2 20.2 13.7 16.7 1.2 20.2 13.3 14.1 1.7 19.1 9.9 281 13 295 165 -10.3 0 -10 -10.6 01/24/2007 03:30:00 19.4 1.9 24 14.1 19.2 1.9 23.7 13.7 16.4 2.3 22.9 10.7 281 11 292 165 -10.3 0.1 -10.2 -10.6 01/24/2007 03:40:00 18.7 1.4 22.1 14.9 18.4 1.4 21.8 14.5 16.5 2 21.4 11.8 277 13 266 165 -10.3 0 -10.2 -10.6 01/24/2007 03:50:00 15.8 2 19.5 10.7 15.6 2 19.9 10.7 13.7 2.6 20.6 7.2 280 12 264 165 -10.3 0 -10.2 -10.6 01/24/2007 04:00:00 17.2 1.9 21.4 11.8 17 2 21 11.8 15.7 2.4 21.4 9.1 277 12 280 165 -10.4 0 -10.2 -10.8 01/24/2007 04:10:00 14.8 2.5 19.9 6.8 14.9 2.4 20.2 8.8 14.1 2.5 19.5 8.8 273 11 282 165 -10.5 0 -10.2 -10.8 01/24/2007 04:20:00 17 2.2 20.6 8 16.9 2.1 20.6 10.3 16.2 2.3 21.8 8.4 275 13 281 165 -10.4 0 -10.2 -10.8 01/24/2007 04:30:00 19.4 1.4 22.9 15.6 19.1 1.4 22.6 15.3 17.7 2.5 23.3 11.5 276 15 276 165 -10.4 0 -10.2 -10.6 01/24/2007 04:40:00 19.8 1.4 23.7 16.4 19.5 1.5 23.7 16.1 16.4 2.5 23.3 11.5 279 14 266 165 -10.4 0 -10.2 -10.6 01/24/2007 04:50:00 19.3 1.7 23.7 15.3 19 1.7 23.3 14.5 15.7 2.3 22.6 11.5 279 15 297 165 -10.5 0.1 -10.2 -10.8 01/24/2007 05:00:00 17.9 1.3 21 14.5 17.7 1.3 20.6 14.1 15.7 2.4 20.6 9.9 279 15 285 165 -10.7 0.1 -10.6 -11 01/24/2007 05:10:00 15.3 1.7 19.1 9.5 15.1 1.7 18.7 9.5 13.9 2.3 19.1 7.2 278 13 278 165 -10.5 0 -10.2 -10.8 01/24/2007 05:20:00 12 1.7 16.1 8 11.8 1.7 16.1 8 10.7 2 16.1 6.5 278 15 238 165 -10.6 0 -10.6 -10.8 01/24/2007 05:30:00 10.3 1.7 15.6 6.5 10.1 1.7 15.6 6.1 9.4 1.9 16.1 5.7 278 15 282 165 -10.6 0 -10.4 -10.8 01/24/2007 05:40:00 11.3 1.7 16.1 7.6 11.5 1.7 16.1 8 10.8 2 16.4 6.1 274 13 282 165 -10.7 0 -10.6 -11 01/24/2007 05:50:00 11.7 2.2 17.9 7.2 11.5 2.2 17.9 7.2 10.5 2.3 16.8 6.1 285 20 274 165 -10.9 0 -10.8 -11 01/24/2007 06:00:00 7.2 3.3 12.6 0.4 7.1 3.3 12.2 0.4 7 2.8 11.5 0.4 277 41 319 165 -10.9 0.1 -10.6 -11.2 01/24/2007 06:10:00 3.5 1.7 9.1 0.4 3.4 1.7 9.1 0.4 3.5 1.7 9.1 0.4 191 53 215 165 -10.9 0 -10.8 -11 01/24/2007 06:20:00 4.1 1.5 8 0.4 4.1 1.5 8 0.4 4.1 1.7 8.8 0.7 242 27 250 165 -11 0 -10.8 -11.2 01/24/2007 06:30:00 5.9 2.1 11.8 2.3 6.2 2 12.2 2.6 5.8 1.8 11.5 1.5 265 16 255 165 -11 0 -10.8 -11.2 01/24/2007 06:40:00 8.2 1.6 13.7 4.2 8.5 1.7 13.7 4.6 7.9 1.9 12.6 3.8 275 15 271 165 -11.2 0 -11 -11.4 01/24/2007 06:50:00 7.3 1.6 11.1 3.8 7.8 1.5 11.8 4.9 7.7 1.3 11.5 4.9 264 13 274 165 -11.1 0 -11 -11.4 01/24/2007 07:00:00 5.9 1.6 11.1 2.3 6.5 1.9 11.1 2.3 6.4 1.8 10.7 3 263 16 252 165 -11.1 0 -11 -11.4 01/24/2007 07:10:00 10.5 3.8 17.9 2.3 10.5 3.6 17.2 1.9 9.9 3.6 17.2 1.9 269 17 271 165 -10.7 0.1 -10.4 -11.4 01/24/2007 07:20:00 13.5 2.6 19.9 5.3 13.6 2.7 20.2 5.7 12.8 2.9 18.3 4.9 272 16 257 165 -10.5 0 -10.4 -10.8 01/24/2007 07:30:00 14.7 2.2 18.7 8.4 14.6 2.1 18.7 8.4 13.3 2.5 19.1 7.2 271 15 282 165 -10.7 0 -10.6 -11 01/24/2007 07:40:00 14.5 2.6 19.5 6.5 14.3 2.5 19.5 6.1 12.2 2.4 18.7 5.3 291 16 297 165 -11 0 -10.6 -11.2 01/24/2007 07:50:00 15.6 2.1 21 10.7 15.4 2 21.4 11.1 13 2 18.7 8 292 15 292 165 -11.2 0 -11 -11.4 01/24/2007 08:00:00 15.9 2.1 21.8 10.7 15.6 2.1 21.8 10.7 12.9 1.9 19.9 8.4 286 13 303 165 -11.1 0 -11 -11.4 01/24/2007 08:10:00 14.4 1.8 18.7 9.9 14.2 1.9 18.7 9.1 12.6 2.6 19.9 7.6 282 18 276 165 -10.9 0.1 -10.6 -11.2 01/24/2007 08:20:00 15.6 1.6 19.9 11.5 15.4 1.6 19.5 11.1 13.6 2.2 19.1 9.1 277 14 260 165 -10.8 0 -10.6 -11 01/24/2007 08:30:00 14.6 1.8 18.7 9.5 14.3 1.8 18.3 9.5 12.3 2.1 17.2 7.6 280 18 294 165 -11 0 -11 -11.2 01/24/2007 08:40:00 13.1 1.9 18.3 8.4 12.8 1.9 17.9 8.4 10.9 2.1 16.8 6.8 285 21 286 165 -11.3 0.1 -11 -11.6 01/24/2007 08:50:00 14.5 2.2 19.9 10.3 14.3 2.2 19.5 9.9 12.1 2.1 18.3 7.6 293 17 297 165 -11.5 0 -11.4 -11.6 01/24/2007 09:00:00 13.7 2.3 19.5 8.8 13.6 2.3 19.1 8.8 11.7 2.5 16.8 6.5 294 15 308 165 -11.5 0 -11.4 -11.6 01/24/2007 09:10:00 12 2.6 18.3 6.8 11.8 2.5 17.9 6.8 10.1 2.1 17.2 6.1 291 18 279 165 -11.5 0.1 -11 -11.8 01/24/2007 09:20:00 12.5 2.5 17.9 6.5 12.3 2.4 16.8 6.1 10.4 2.1 15.3 5.3 295 18 217 165 -11.3 0 -11 -11.4 01/24/2007 09:30:00 7.8 1.3 10.7 4.2 7.8 1.3 10.7 4.2 7.2 1.4 11.1 3.8 303 21 300 165 -11.3 0.1 -11 -11.8 01/24/2007 09:40:00 9.7 2.6 15.6 4.2 9.5 2.6 15.6 4.2 8.1 2.2 13.3 2.6 292 20 284 165 -11 0.1 -10.8 -11.4 01/24/2007 09:50:00 9.6 2.7 17.9 3.4 9.6 2.6 17.9 3.8 8.3 2.2 14.1 3.4 283 20 271 165 -10.8 0 -10.6 -11 01/24/2007 10:00:00 12.7 1.9 17.6 8 12.5 1.8 17.2 7.6 10.8 1.8 16.1 6.8 279 16 268 165 -10.9 0 -10.6 -11 01/24/2007 10:10:00 9.4 2.5 17.2 3.4 9.3 2.4 17.2 3 7.9 2.4 14.5 2.3 282 21 293 165 -10.6 0.2 -10.2 -11 01/24/2007 10:20:00 8.4 3.3 16.4 3 8.3 3.2 16.1 2.6 7.1 3.2 16.1 1.9 278 19 288 165 -10.5 0.1 -10.2 -10.8 01/24/2007 10:30:00 6.6 2.1 12.2 0.7 6.9 2.2 11.8 1.1 5.8 2.5 11.5 0.4 272 23 281 165 -10.2 0.1 -10 -10.4 01/24/2007 10:40:00 6.7 2.2 12.2 1.9 6.9 2.2 12.2 1.9 6.2 2.1 11.5 1.1 253 35 234 165 -10.2 0 -10 -10.6 01/24/2007 10:50:00 7.4 2.4 13.7 2.6 7.7 2.4 13.7 3 6.8 2.2 13 2.3 277 27 261 165 -10.1 0.1 -9.7 -10.4 01/24/2007 11:00:00 6.2 2 11.5 2.3 6.2 1.9 11.1 2.6 4.7 1.7 10.7 1.9 286 21 319 165 -9.6 0 -9.3 -10.2 01/24/2007 11:10:00 9.1 2.3 14.9 3 9 2.2 14.9 2.6 7.8 2.3 13.3 1.5 285 20 307 165 -10.1 0.2 -9.5 -10.4 01/24/2007 11:20:00 10 1.8 14.9 4.2 9.8 1.7 14.1 4.2 8.3 1.7 12.6 4.2 289 18 299 165 -10.1 0.1 -9.7 -10.4 01/24/2007 11:30:00 6.4 1.7 11.1 2.3 6.7 1.7 11.8 2.6 5.9 1.5 10.3 1.5 273 19 272 165 -9.9 0.1 -9.7 -10.4 01/24/2007 11:40:00 6.1 1.8 12.6 3 6.5 1.8 13 3 6.2 1.7 12.2 2.3 262 16 243 165 -9.6 0 -9.3 -9.7 01/24/2007 11:50:00 5.9 1.4 9.5 3.4 6.1 1.4 9.5 3.4 5.9 1.3 9.1 2.3 268 17 286 165 -9.5 0 -9.3 -9.7 01/24/2007 12:00:00 8.5 2.3 13.7 3.4 8.7 2.1 14.1 3.4 8.5 2.1 14.5 3.4 272 12 315 165 -9.6 0.1 -9.3 -9.7 01/24/2007 12:10:00 9.4 1.7 13.3 5.3 9.3 1.7 13 5.3 8.3 1.9 13 4.6 283 17 274 165 -9.4 0.1 -9.1 -9.7 01/24/2007 12:20:00 9.1 1.8 13 3.8 9 1.7 13 4.2 7.6 1.7 13.3 3.4 287 18 315 165 -9.4 0 -9.3 -9.7 01/24/2007 12:30:00 9.7 1.7 13.7 5.7 9.5 1.7 13.3 5.7 8.2 1.7 13 4.2 296 16 303 165 -9.1 0.2 -8.9 -9.5 01/24/2007 12:40:00 8.5 1.9 12.6 4.6 8.4 1.9 12.2 3.8 7.2 1.7 11.8 3 294 17 293 165 -9.1 0.1 -8.9 -9.5 01/24/2007 12:50:00 7.3 1.3 11.5 4.2 7.2 1.3 11.1 4.2 6.2 1.3 10.3 3 284 12 290 165 -9 0 -8.9 -9.5 01/24/2007 13:00:00 6.7 1.5 9.9 3.4 6.6 1.3 9.9 3.8 5.6 1.4 9.9 2.6 289 15 301 165 -8.8 0.2 -8.3 -9.3 01/24/2007 13:10:00 7.1 1.3 11.1 3.8 7 1.3 10.7 3.8 5.8 1.1 9.9 2.6 295 13 311 165 -8.7 0.1 -8.3 -8.9 01/24/2007 13:20:00 5.1 1.1 8 2.3 5.2 1.1 8 2.6 4.6 1 6.8 2.3 284 17 304 165 -8.5 0.1 -8.3 -8.9 01/24/2007 13:30:00 2.6 1.1 6.1 0.4 2.6 1.1 6.5 0.4 2.3 1.1 4.9 0.4 277 90 266 165 -7.5 0.6 -6.8 -8.9 01/24/2007 13:40:00 3.2 1.1 5.7 0.4 3.2 1.1 6.1 0.4 3 1 5.3 0.4 296 17 329 165 -7.4 0.2 -6.8 -7.9 01/24/2007 13:50:00 1.5 0.8 4.2 0.4 1.5 0.8 4.2 0.4 1.6 0.8 4.2 0.4 228 51 284 165 -6.8 0.3 -6.1 -7.4 01/24/2007 14:00:00 2.4 0.7 4.2 0.7 2.5 0.7 4.2 0.7 2.3 0.8 4.9 0.4 232 21 249 165 -6.8 0.1 -6.4 -7 01/24/2007 14:10:00 2.6 0.7 4.6 0.7 2.7 0.7 4.2 0.7 2.7 0.7 4.6 1.1 217 29 179 165 -7.1 0.2 -6.8 -7.4 01/24/2007 14:20:00 2.4 1.4 6.5 0.4 2.4 1.4 6.1 0.4 2 1.1 4.9 0.4 303 82 279 165 -7.1 0.3 -6.1 -7.4 01/24/2007 14:30:00 2.1 0.9 4.2 0.4 2 0.9 3.8 0.4 1.7 0.7 3.8 0.4 312 21 350 165 -6.5 0.3 -5.9 -7 01/24/2007 14:40:00 4.1 1.3 6.8 1.5 4.1 1.2 6.8 1.9 3.7 1.1 6.1 1.1 295 36 285 165 -7.2 0.7 -5.9 -8.1 01/24/2007 14:50:00 3.4 1.3 6.5 0.7 3.4 1.3 6.1 0.7 2.9 1.2 6.5 1.1 306 26 332 165 -7.5 0.2 -7 -8.3 01/24/2007 15:00:00 3.9 1.2 7.6 1.5 4 1.2 7.6 1.9 3.6 1.2 6.8 1.1 279 17 309 165 -7.9 0.2 -7.2 -8.5 01/24/2007 15:10:00 5.5 1.1 7.6 3 5.4 1.1 7.6 2.6 5.2 1.1 8 2.6 296 17 312 165 -8 0.1 -7.6 -8.5 01/24/2007 15:20:00 6.8 0.5 8 5.3 6.7 0.5 8 5.3 5.5 1 7.2 3.4 291 7 293 165 -8.2 0 -8.1 -8.5 01/24/2007 15:30:00 6.4 0.4 7.2 5.3 6.4 0.4 7.2 5.7 6.2 0.7 7.6 4.2 286 5 282 165 -8.4 0.1 -8.3 -8.7 01/24/2007 15:40:00 4.8 1.1 6.5 2.3 4.7 1.2 6.8 2.3 3.5 0.9 5.3 1.5 297 5 290 165 -8.5 0 -8.3 -8.7 01/24/2007 15:50:00 1.8 0.9 3.8 0.4 1.8 0.9 3.8 0.4 1.5 0.6 3.4 0.4 261 24 286 165 -7.9 0.5 -6.8 -8.7 01/24/2007 16:00:00 0.5 0.4 3 0.4 0.5 0.4 3 0.4 0.5 0.4 2.6 0.4 315 94 294 165 -6.8 0.1 -6.4 -7.2 01/24/2007 16:10:00 2 0.8 3.4 0.4 2.1 0.8 3.4 0.4 1.8 0.8 3.4 0.4 272 18 276 165 -7.5 0.4 -6.4 -8.5 01/24/2007 16:20:00 1.9 0.5 3.4 0.7 1.9 0.5 3.4 1.1 1.8 0.6 3.4 0.7 284 13 271 165 -8.6 0.1 -8.3 -9.1 01/24/2007 16:30:00 2.3 0.5 3.4 1.1 2.2 0.5 3.4 1.1 2.3 0.5 3.8 1.1 321 13 319 165 -8.5 0.3 -8.1 -9.3 01/24/2007 16:40:00 4.2 1 6.1 1.9 4.2 0.9 6.1 1.9 3.5 0.8 5.7 1.5 297 10 290 165 -8.9 0.2 -8.3 -9.3 01/24/2007 16:50:00 4.5 0.6 5.7 2.6 4.5 0.5 5.7 3 4.2 0.7 5.7 2.6 286 9 288 165 -9.1 0 -8.9 -9.3 01/24/2007 17:00:00 4.2 0.4 5.3 3 4.2 0.4 5.3 3 4.1 0.5 5.3 2.6 283 6 277 165 -9.5 0.1 -9.1 -10 01/24/2007 17:10:00 3.3 0.6 4.6 1.5 3.5 0.4 4.6 2.6 3.5 0.4 4.6 2.6 269 8 284 165 -9.6 0 -9.3 -9.7 01/24/2007 17:20:00 3 0.4 3.8 1.9 3.2 0.4 3.8 2.3 3.2 0.3 3.8 2.3 267 6 266 165 -9.2 0.1 -8.9 -9.7 01/24/2007 17:30:00 1.8 0.5 3 0.4 1.8 0.6 2.6 0.4 2.2 0.5 3.4 0.7 256 23 251 165 -9.1 0 -8.9 -9.3 01/24/2007 17:40:00 1.9 0.4 3 1.1 1.8 0.4 2.6 0.7 1.7 0.4 2.6 0.7 288 10 279 165 -9 0 -8.9 -9.1 01/24/2007 17:50:00 1.5 0.5 2.3 0.4 1.4 0.5 2.6 0.4 1.5 0.5 2.6 0.4 267 13 269 165 -9.2 0 -9.1 -9.3 01/24/2007 18:00:00 1.3 0.4 2.6 0.4 1.2 0.4 2.3 0.4 1.2 0.4 2.3 0.4 267 22 286 165 -9.4 0 -9.3 -9.7 01/24/2007 18:10:00 1.5 0.2 2.3 0.7 1.3 0.2 1.9 0.7 1.4 0.3 1.9 0.7 304 15 287 165 -9.4 0.2 -9.1 -9.7 01/24/2007 18:20:00 0.9 0.4 1.5 0.4 0.6 0.3 1.5 0.4 1.4 0.3 2.3 0.7 334 5 320 165 -10.2 0.1 -9.7 -10.6 01/24/2007 18:30:00 1.7 0.5 2.3 0.7 1 0.3 1.9 0.4 1.9 0.4 2.3 1.1 348 8 347 165 -10.3 0 -10.2 -10.6 01/24/2007 18:40:00 0.7 0.3 1.5 0.4 0.6 0.3 1.5 0.4 1 0.5 1.9 0.4 32 12 20 165 -9.7 0.5 -8.9 -10.6 01/24/2007 18:50:00 0.7 0.4 1.9 0.4 0.5 0.3 1.5 0.4 1 0.6 2.3 0.4 10 20 354 165 -9.2 0.1 -8.9 -9.5 01/24/2007 19:00:00 0.4 0.1 1.1 0.4 0.4 0.1 1.1 0.4 0.4 0.1 1.1 0.4 120 69 208 165 -9.2 0.1 -8.9 -9.3 01/24/2007 19:10:00 0.6 0.3 1.5 0.4 0.5 0.3 1.5 0.4 0.5 0.3 1.9 0.4 186 23 166 165 -9.2 0 -8.9 -9.3 01/24/2007 19:20:00 0.4 0.2 1.1 0.4 0.4 0.1 0.7 0.4 0.4 0.1 0.7 0.4 165 0 165 165 -9.2 0.1 -8.9 -9.3 01/24/2007 19:30:00 0.8 0.5 1.5 0.4 0.7 0.4 1.5 0.4 0.8 0.5 1.9 0.4 165 0 165 165 -9.4 0 -9.3 -9.7 01/24/2007 19:40:00 0.7 0.4 1.5 0.4 0.6 0.3 1.5 0.4 0.7 0.4 1.5 0.4 165 0 165 165 -9.4 0 -9.3 -9.7 01/24/2007 19:50:00 1.4 0.2 1.9 0.7 1.2 0.2 1.9 0.7 1.3 0.2 1.9 0.7 164 0 163 165 -9.6 0.1 -9.3 -9.7 01/24/2007 20:00:00 1.6 0.3 2.3 1.1 1.4 0.3 2.3 1.1 1.4 0.3 2.3 0.7 167 4 174 165 -9.5 0 -9.3 -9.7 01/24/2007 20:10:00 1.8 0.4 2.6 1.1 1.6 0.4 2.3 0.7 1.6 0.5 2.3 0.4 176 2 176 165 -9.4 0 -9.1 -9.7 01/24/2007 20:20:00 0.5 0.3 1.5 0.4 0.4 0.2 1.1 0.4 0.4 0.1 1.1 0.4 175 0 176 165 -9.5 0 -9.3 -9.7 01/24/2007 20:30:00 2 0.5 2.6 0.4 1.8 0.6 2.6 0.4 2 0.6 2.6 0.4 176 3 176 165 -9.2 0.1 -9.1 -9.5 01/24/2007 20:40:00 1.4 0.6 2.3 0.4 1.3 0.6 2.3 0.4 1.3 0.6 2.3 0.4 170 8 176 165 -9.1 0 -8.9 -9.1 01/24/2007 20:50:00 1 0.4 1.9 0.4 0.9 0.4 1.9 0.4 0.8 0.4 1.9 0.4 158 8 172 165 -9.2 0 -8.9 -9.3 01/24/2007 21:00:00 1.2 0.5 2.6 0.4 1.1 0.5 2.6 0.4 1 0.5 2.6 0.4 162 8 152 165 -9 0 -8.7 -9.3 01/24/2007 21:10:00 1.8 0.4 3 0.7 1.8 0.3 3 0.7 1.6 0.4 3 0.4 149 7 158 165 -8.9 0 -8.7 -9.1 01/24/2007 21:20:00 1.4 0.7 2.6 0.4 1.4 0.8 3 0.4 0.9 0.6 2.3 0.4 97 29 84 165 -9.1 0 -8.9 -9.1 01/24/2007 21:30:00 2.3 0.3 3 1.5 2.4 0.3 3 1.9 2.4 0.3 3 1.1 105 11 91 165 -9 0 -8.7 -9.1 01/24/2007 21:40:00 2.5 0.4 3 1.5 2.6 0.4 3.4 1.5 2.3 0.2 3 1.9 114 3 115 165 -8.8 0 -8.7 -9.1 01/24/2007 21:50:00 1.6 0.5 2.6 0.7 1.7 0.5 2.6 1.1 1.4 0.5 2.6 0.7 108 6 117 165 -8.8 0 -8.7 -9.1 01/24/2007 22:00:00 2 0.3 2.6 1.1 2.1 0.2 2.6 1.5 1.7 0.3 2.3 1.1 98 5 94 165 -8.8 0 -8.5 -8.9 01/24/2007 22:10:00 1.8 0.3 2.6 1.1 1.9 0.3 3 1.5 1.5 0.3 2.3 0.7 111 9 109 165 -8.9 0 -8.7 -9.1 01/24/2007 22:20:00 2.6 0.4 3.4 1.9 2.7 0.4 3.4 1.9 2.2 0.4 3 1.1 101 6 101 165 -8.6 0.1 -8.3 -8.9 01/24/2007 22:30:00 2.6 0.3 3 1.9 2.7 0.3 3.4 1.9 2.3 0.2 2.6 1.9 106 5 99 165 -8.5 0.1 -8.3 -8.9 01/24/2007 22:40:00 2.2 0.4 3 1.5 2.3 0.4 3.4 1.5 1.9 0.3 2.6 1.1 110 2 110 165 -8.3 0 -8.1 -8.5 01/24/2007 22:50:00 2.1 0.4 2.6 1.1 2.2 0.4 3 1.5 1.7 0.4 2.6 0.7 110 6 115 165 -8.2 0.1 -7.9 -8.5 01/24/2007 23:00:00 2.7 0.3 3.8 1.9 2.7 0.3 3.8 2.3 2.6 0.4 3.8 1.1 129 9 149 165 -7.8 0.1 -7.4 -8.1 01/24/2007 23:10:00 3.5 0.2 3.8 3 3.4 0.2 3.8 3 3.3 0.2 3.8 2.6 152 7 148 165 -7.8 0 -7.4 -8.1 01/24/2007 23:20:00 4.1 0.5 5.3 2.6 4.1 0.5 5.3 2.6 3.5 0.4 4.6 2.6 139 7 136 165 -7.4 0.1 -7 -7.9 01/24/2007 23:30:00 4.1 0.4 5.3 3 4.1 0.4 5.3 3.4 3.8 0.4 4.9 2.3 139 4 139 165 -7.1 0 -6.8 -7.2 01/24/2007 23:40:00 4.6 0.7 6.5 3 4.6 0.7 6.5 3 4.1 0.7 6.1 2.6 138 3 130 165 -6.9 0.2 -6.6 -7.2 01/24/2007 23:50:00 4.8 1.1 7.6 2.6 4.8 1.1 7.6 2.6 4.8 1 7.2 1.9 134 10 142 165 -6.1 0 -5.7 -6.8 01/25/2007 00:00:00 4.9 0.8 6.8 3 4.9 0.8 7.2 3.4 4.8 0.8 6.8 3 131 8 132 165 -6.1 0 -5.7 -6.4 01/25/2007 00:10:00 5.3 0.6 6.8 3.8 5.2 0.6 6.5 3.8 5.1 0.5 6.8 3.8 130 6 133 165 -6.1 0 -5.9 -6.4 01/25/2007 00:20:00 6 0.6 7.2 4.6 6.1 0.6 6.8 4.2 5.7 0.7 6.8 3.8 123 5 121 165 -6 0.1 -5.7 -6.4 01/25/2007 00:30:00 5.5 0.6 6.8 3.4 5.5 0.6 6.8 3.4 5.2 0.6 6.5 3.4 121 5 124 165 -5.8 0 -5.5 -5.9 01/25/2007 00:40:00 6.7 0.4 7.2 5.3 6.8 0.4 7.2 5.3 6.4 0.5 7.2 4.2 119 3 125 165 -5.7 0 -5.5 -5.9 01/25/2007 00:50:00 6.5 0.4 7.2 5.7 6.6 0.4 7.2 5.7 6.2 0.5 7.2 4.6 118 3 128 165 -5.4 0 -5 -5.7 01/25/2007 01:00:00 5.9 0.3 6.5 4.6 6 0.3 6.5 4.6 5.7 0.3 6.5 4.2 112 4 119 165 -5.3 0.1 -5 -5.5 01/25/2007 01:10:00 6.7 0.4 7.6 5.7 6.9 0.4 7.6 6.1 6.6 0.4 7.6 5.3 110 3 114 165 -4.9 0.1 -4.6 -5.3 01/25/2007 01:20:00 6.9 0.3 7.6 5.3 7 0.3 8 5.3 6.7 0.4 8 5.3 110 2 111 165 -4.7 0 -4.4 -4.8 01/25/2007 01:30:00 7.5 0.4 8.4 6.8 7.7 0.4 8.4 6.8 7.3 0.4 8.4 5.3 104 3 101 165 -4.3 0.1 -3.9 -4.6 01/25/2007 01:40:00 7.9 0.5 9.1 6.5 8.1 0.5 9.5 6.5 7.7 0.6 9.1 4.9 101 6 99 165 -4.1 0 -3.9 -4.4 01/25/2007 01:50:00 8.5 0.6 9.9 7.2 8.7 0.6 10.3 7.2 8.3 0.7 9.9 6.5 90 3 88 165 -4.1 0 -3.9 -4.4 01/25/2007 02:00:00 7.4 1 9.5 3.8 7.5 1.1 9.5 3.8 6.8 1.1 8.8 3.4 100 9 102 165 -4.1 0.1 -3.7 -4.4 01/25/2007 02:10:00 7.7 0.9 9.5 5.3 7.7 0.9 10.3 5.3 7.1 1 9.5 4.6 115 8 111 165 -4.2 0 -3.9 -4.4 01/25/2007 02:20:00 8.7 0.8 11.1 6.8 8.8 0.9 11.5 6.5 8.5 0.8 10.7 6.1 121 6 115 165 -3.9 0.1 -3.5 -4.4 01/25/2007 02:30:00 8.9 0.8 10.7 7.2 8.9 0.7 10.7 6.8 8.6 0.8 10.7 6.1 123 5 124 165 -3.7 0.1 -3.5 -3.9 01/25/2007 02:40:00 10.7 0.9 12.6 8 10.7 0.9 13 8 10.3 0.9 12.6 8 121 5 112 165 -3.3 0.2 -2.8 -3.9 01/25/2007 02:50:00 10.8 1.2 14.5 4.9 10.8 1.2 14.5 5.7 10.5 1.3 14.5 5.7 119 5 128 165 -2.9 0.1 -2.6 -3.3 01/25/2007 03:00:00 13.5 2.1 17.2 9.1 13.6 2.1 17.2 9.1 12.9 2.2 17.6 8.4 117 6 124 165 -2.2 0.2 -1.9 -2.6 01/25/2007 03:10:00 13.6 1.2 16.8 9.9 13.8 1.2 16.8 10.3 13.3 1.2 16.1 9.9 119 6 121 165 -2 0 -1.9 -2.1 01/25/2007 03:20:00 12.2 1.5 16.4 8.4 12.3 1.6 16.4 8.4 11.9 1.5 16.1 7.2 118 7 120 165 -1.8 0 -1.7 -2.1 01/25/2007 03:30:00 13.3 1.5 16.8 8.4 13.4 1.5 16.8 9.1 12.9 1.5 16.4 9.1 118 8 116 165 -1.7 0 -1.4 -1.9 01/25/2007 03:40:00 13.9 1.9 18.7 8.4 14.1 2 19.1 9.1 13.2 2.3 17.6 8 112 8 116 165 -1.5 0 -1.4 -1.7 01/25/2007 03:50:00 15.8 1.4 18.7 11.5 15.9 1.5 19.1 10.7 15.1 1.6 19.1 9.9 114 7 86 165 -1.4 0 -1.2 -1.4 01/25/2007 04:00:00 16 2.3 20.6 8.8 16.1 2.3 21 9.1 15.2 2.4 20.6 8.4 109 6 111 165 -1.3 0 -1.2 -1.4 01/25/2007 04:10:00 16.3 1.3 20.2 11.8 16.4 1.3 20.2 11.8 15.4 1.6 19.5 10.7 109 7 119 165 -1.2 0 -1 -1.4 01/25/2007 04:20:00 17 1.5 22.9 12.6 17.1 1.5 22.1 12.2 16.4 1.9 21 11.5 112 6 106 165 -0.9 0 -0.5 -1.2 01/25/2007 04:30:00 17.2 1.5 21 12.2 17.2 1.5 21 11.8 16.6 1.7 20.6 11.5 109 5 121 165 -0.6 0 -0.5 -0.8 01/25/2007 04:40:00 16.3 1.9 21.8 11.8 16.3 1.9 21.4 11.8 15.6 2.1 21 10.3 114 6 121 165 -0.5 0 -0.3 -0.8 01/25/2007 04:50:00 16.1 1.7 21.8 9.9 16.1 1.7 21.8 10.3 15.6 1.8 21 11.1 114 8 102 165 -0.3 0 -0.1 -0.5 01/25/2007 05:00:00 16.1 1.7 22.6 12.2 16 1.7 22.1 11.8 15.8 1.8 21.8 10.7 115 7 110 165 -0.2 0 -0.1 -0.3 01/25/2007 05:10:00 15.2 1.9 20.2 9.5 15.1 1.9 20.6 9.1 15 2.1 20.6 9.5 117 7 121 165 -0.1 0 0.2 -0.3 01/25/2007 05:20:00 15.2 1.7 19.1 10.7 15.2 1.7 19.5 10.3 14.9 1.8 19.1 9.9 118 6 122 165 -0.1 0 0.2 -0.3 01/25/2007 05:30:00 14.8 2 20.6 9.9 14.8 1.9 20.6 9.9 14.7 2 21 9.5 120 7 116 165 0.1 0 0.2 -0.1 01/25/2007 05:40:00 15.4 2.5 21.4 9.1 15.4 2.4 21.4 9.5 15.2 2.5 21 9.1 119 9 111 165 0.1 0 0.2 -0.1 01/25/2007 05:50:00 15.1 1.7 19.5 11.5 15 1.7 19.5 11.5 15 1.7 19.1 10.3 125 8 122 165 0.1 0 0.2 -0.1 01/25/2007 06:00:00 15.8 1.7 20.2 10.7 15.7 1.7 19.9 10.7 15.9 1.8 20.6 11.1 126 8 121 165 0.2 0 0.2 0.2 01/25/2007 06:10:00 15.7 1.7 20.6 10.7 15.7 1.8 20.6 11.5 16 2 21 11.5 126 9 128 165 0.2 0 0.4 -0.1 01/25/2007 06:20:00 17.4 2 22.9 10.7 17.4 2 22.6 10.7 17.6 2.2 23.3 11.5 125 8 136 165 0.2 0 0.4 0.2 01/25/2007 06:30:00 15.2 1.5 19.9 11.8 15.2 1.5 19.9 12.2 15.5 1.6 19.5 10.3 133 9 142 165 0.2 0 0.4 0.2 01/25/2007 06:40:00 17.1 1.9 22.1 11.8 17 1.9 21.8 11.5 17.4 2.1 23.3 12.2 136 12 145 165 0.2 0 0.4 0.2 01/25/2007 06:50:00 18.9 1.7 23.7 14.1 18.8 1.7 23.3 14.5 19.3 2 24 14.1 138 6 138 165 0.4 0 0.7 0.2 01/25/2007 07:00:00 19.8 1.8 24.8 13.3 19.6 1.7 24.4 13.7 20.1 1.9 25.2 15.3 138 0 138 165 0.4 0 0.7 0.2 01/25/2007 07:10:00 19.2 1.8 24 14.1 19 1.7 23.7 14.1 19.2 1.9 24 14.9 138 0 138 165 0.4 0 0.7 0.2 01/25/2007 07:20:00 17.8 1.4 22.9 14.1 17.7 1.3 22.6 14.1 17.7 1.5 22.1 14.1 138 0 138 165 0.4 0 0.9 0.2 01/25/2007 07:30:00 18.4 1.3 22.9 14.1 18.3 1.3 22.1 14.5 18.4 1.5 22.1 14.5 138 0 138 165 0.5 0 0.7 0.4 01/25/2007 07:40:00 18.5 1.2 22.1 15.3 18.5 1.2 21.8 15.3 18.3 1.5 23.3 14.9 138 0 138 165 0.5 0 0.7 0.2 01/25/2007 07:50:00 19.4 1.7 23.7 15.3 19.1 1.7 23.3 15.3 19.1 1.9 24 14.9 138 0 138 165 0.5 0 0.9 0.4 01/25/2007 08:00:00 20.4 1.5 24 15.3 20.1 1.6 24.4 14.5 20.5 1.5 24.8 16.4 138 0 138 165 0.7 0 0.9 0.4 01/25/2007 08:10:00 19.2 1.6 22.6 15.3 19.3 1.7 22.9 15.6 19.4 1.6 23.3 15.6 138 0 138 165 0.7 0 0.9 0.7 01/25/2007 08:20:00 17.9 1.3 21.8 14.5 18.2 1.3 22.1 14.5 18.3 1.3 22.1 14.5 138 0 138 165 0.7 0 0.9 0.7 01/25/2007 08:30:00 17.3 1.1 20.2 14.1 17.6 1.1 20.6 14.5 17.8 1.2 21 14.9 138 0 138 165 0.7 0 0.9 0.7 01/25/2007 08:40:00 16.8 1.2 19.5 13 17 1.2 19.9 13 17.5 1.2 21.4 14.1 138 0 138 165 0.6 0 0.9 0.4 01/25/2007 08:50:00 15.3 1.3 18.7 12.2 15.2 1.4 18.3 11.8 15.4 1.6 19.1 11.8 138 0 138 165 0.5 0 0.9 0.4 01/25/2007 09:00:00 14.7 0.8 16.8 11.8 14.5 0.8 16.4 11.8 14.9 1 17.2 12.2 138 0 138 165 0.5 0 0.7 0.4 01/25/2007 09:10:00 13.8 1 16.8 10.3 13.8 1.1 16.8 9.9 15.5 1.3 19.9 11.1 138 0 138 165 0.6 0 0.9 0.4 01/25/2007 09:20:00 13.6 0.9 15.6 10.7 14.6 0.9 17.2 11.5 15.3 1.2 17.9 11.8 138 0 138 165 0.7 0 0.9 0.7 01/25/2007 09:30:00 13.3 1.8 16.8 9.1 15.2 1.8 19.1 12.2 15.5 1.7 19.5 12.2 138 0 138 165 0.8 0 0.9 0.7 01/25/2007 09:40:00 12.4 1 14.9 9.9 15.7 1.2 19.1 12.2 16.3 1.3 19.9 13 138 0 138 165 0.8 0 1.1 0.7 01/25/2007 09:50:00 12.2 0.7 14.1 10.3 15.2 0.9 17.2 12.6 15.7 1 18.3 13 138 0 138 165 1.1 0 1.4 0.9 01/25/2007 10:00:00 12.2 0.8 13.7 9.9 14.9 1 17.2 12.6 14.5 1 16.8 11.8 138 0 138 165 1.1 0 1.4 0.9 01/25/2007 10:10:00 11.9 0.8 13.7 9.9 14.3 1.1 17.2 11.1 7.9 1.6 14.5 6.8 138 0 138 165 1.1 0 1.4 0.9 01/25/2007 10:20:00 11.2 0.6 12.6 9.5 12.9 0.7 14.5 10.7 7.1 0.2 7.6 6.5 138 0 138 165 1.1 0 1.4 0.9 01/25/2007 10:30:00 10.8 1 12.6 8 7.4 1.8 11.5 5.7 6.9 0.2 7.2 6.1 138 0 138 165 1.1 0 1.4 0.9 01/25/2007 10:40:00 9.9 0.8 11.8 8 6.2 0.5 9.9 5.7 6.7 0.2 7.2 6.1 138 0 138 165 1.1 0 1.4 0.9 01/25/2007 10:50:00 9.6 0.8 11.5 7.6 6 0.2 6.5 5.3 6.5 0.2 7.2 5.7 138 0 138 165 1.1 0 1.4 0.9 01/25/2007 11:00:00 8.9 0.7 11.1 7.2 5.8 0.2 6.5 4.9 6.4 0.2 6.8 5.7 138 0 138 165 1.3 0 1.4 1.1 01/25/2007 11:10:00 8 0.5 9.5 6.8 5.6 0.2 6.1 4.9 6.4 0.3 6.8 5.7 138 0 138 165 1.4 0 1.6 1.4 01/25/2007 11:20:00 7.6 0.5 8.8 6.1 5.7 0.2 6.1 4.9 6.5 0.2 6.8 6.1 138 0 138 165 1.4 0 1.6 1.4 01/25/2007 11:30:00 7.6 0.4 8.4 6.5 9.9 6.4 21.8 4.6 6.5 0.2 6.8 6.1 137 12 138 165 1.5 0 1.6 1.4 01/25/2007 11:40:00 8 0.4 9.1 6.8 18.8 1.2 22.1 14.9 6.7 0.2 7.2 6.1 141 6 145 165 1.5 0 1.6 1.4 01/25/2007 11:50:00 7.7 1 9.1 5.7 17.5 0.9 19.9 14.9 6.9 0.3 7.6 6.5 146 8 145 165 1.5 0 1.6 1.4 01/25/2007 12:00:00 6.3 1.7 18.7 5.3 16.5 0.9 18.7 14.1 8.3 1.1 9.9 6.8 147 10 148 165 1.5 0 1.6 1.4 01/25/2007 12:10:00 16 1.1 19.1 12.6 15.9 1.1 18.7 12.2 15.1 1.9 17.6 9.5 146 12 151 165 1.5 0 1.6 1.4 01/25/2007 12:20:00 14.6 1 16.8 12.2 14.5 1 16.8 12.2 14.3 1.1 16.4 11.1 145 15 153 165 1.5 0 1.6 1.4 01/25/2007 12:30:00 13.4 1.1 16.1 10.7 13.3 1 16.1 10.3 13.2 1.1 15.6 9.9 147 6 150 165 1.5 0 1.6 1.4 01/25/2007 12:40:00 13.2 0.6 14.5 11.5 13.1 0.6 14.5 11.1 13.1 0.7 15.3 11.5 148 8 153 165 1.5 0 1.6 1.4 01/25/2007 12:50:00 12.5 0.6 13.7 9.5 12.3 0.6 13.7 9.5 12.5 0.8 14.1 9.9 148 12 149 165 1.5 0 1.6 1.4 01/25/2007 13:00:00 11.1 0.7 12.2 9.1 10.9 0.7 12.6 8.8 11.1 0.7 12.6 9.1 145 21 157 165 1.5 0 1.6 1.4 01/25/2007 13:10:00 9.1 0.7 10.3 6.8 8.8 0.6 9.9 6.8 9.2 0.7 10.3 7.2 148 21 153 165 1.5 0 1.8 1.4 01/25/2007 13:20:00 9.3 1.3 11.8 6.8 8.9 1.3 11.5 6.8 9 1.1 11.8 7.2 156 21 169 165 1.6 0 1.6 1.4 01/25/2007 13:30:00 10.9 0.9 13.7 8.8 10.6 0.8 13 8.8 10.8 0.9 13 9.1 154 35 177 165 1.7 0.1 2.1 1.6 01/25/2007 13:40:00 11.9 0.8 14.1 9.9 11.6 0.7 13.3 9.5 11.7 0.6 13.3 10.3 155 30 165 165 2 0 2.3 1.8 01/25/2007 13:50:00 11.7 0.8 13.7 9.5 11.4 0.8 13.3 8.8 11.6 0.7 13.7 9.5 151 30 170 165 2.3 0.1 2.6 2.1 01/25/2007 14:00:00 14.3 1.3 17.6 9.1 13.9 1.2 16.8 8.8 14.1 1.4 17.2 10.3 168 21 176 165 2.7 0.1 3 2.3 01/25/2007 14:10:00 15.6 1 17.9 12.6 15.3 1 17.6 12.6 15.7 1.1 17.9 13 160 28 168 165 2.2 0.4 3 1.6 01/25/2007 14:20:00 13.5 1 16.1 11.1 13.2 0.9 15.6 11.5 13.6 1 16.1 10.7 162 20 166 165 2.5 0.5 3 1.6 01/25/2007 14:30:00 12 0.9 14.9 9.5 11.7 0.9 14.5 9.1 12.1 0.9 14.9 10.3 164 15 169 165 2.9 0 3 2.8 01/25/2007 14:40:00 12.7 0.7 14.9 11.1 12.3 0.7 14.5 10.7 12.6 0.7 14.9 10.7 171 12 168 165 3 0 3.3 2.6 01/25/2007 14:50:00 11.8 0.9 14.1 9.5 11.3 0.8 13.7 9.1 11.7 0.8 14.1 8.8 169 14 169 165 2.9 0 3.3 2.6 01/25/2007 15:00:00 10.3 0.7 12.2 8.4 9.9 0.7 12.2 8.4 10.2 0.8 12.6 8 170 12 175 165 2.9 0 3 2.6 01/25/2007 15:10:00 9.8 0.9 11.8 8 9.4 0.8 11.5 7.6 9.9 0.8 12.2 7.6 170 11 169 165 2.9 0 3 2.8 01/25/2007 15:20:00 8.9 1 12.2 6.5 8.6 1 11.8 6.5 9 0.9 11.5 6.8 162 21 156 165 2.9 0 3.3 2.6 01/25/2007 15:30:00 8.6 0.6 9.9 6.8 8.4 0.6 9.5 6.8 8.8 0.5 10.3 7.6 153 24 159 165 2.7 0 3 2.6 01/25/2007 15:40:00 8.4 0.5 9.9 6.5 8.1 0.5 9.5 6.5 8.5 0.5 9.5 7.2 150 24 82 165 2.7 0 3 2.6 01/25/2007 15:50:00 8.9 0.6 10.7 7.6 8.6 0.6 10.3 7.2 9 0.6 10.7 8 148 24 133 165 2.7 0 2.8 2.6 01/25/2007 16:00:00 8.7 0.7 11.1 6.8 8.5 0.6 10.7 6.8 8.7 0.6 10.3 7.2 147 22 172 165 2.6 0 2.8 2.6 01/25/2007 16:10:00 10 1 12.6 8 9.8 1 12.2 8 10 0.9 12.2 8 148 18 155 165 2.6 0 2.8 2.3 01/25/2007 16:20:00 8.9 0.8 10.7 6.5 8.7 0.8 10.3 6.5 8.8 0.8 10.3 6.8 148 13 150 165 2.6 0 2.8 2.3 01/25/2007 16:30:00 9.2 0.5 10.7 7.6 9 0.5 10.3 7.6 8.9 0.6 10.7 7.6 147 3 147 165 2.6 0 2.8 2.3 01/25/2007 16:40:00 9.6 0.4 10.7 8 9.4 0.4 10.3 8 9.5 0.5 10.3 8 148 2 145 165 2.5 0 2.8 2.3 01/25/2007 16:50:00 9.6 0.5 10.7 8.4 9.4 0.5 10.7 8.4 9.4 0.5 10.7 8 147 3 145 165 2.5 0 2.8 2.3 01/25/2007 17:00:00 9.3 0.5 10.3 7.6 9.2 0.5 10.3 8 9.1 0.5 10.3 7.6 148 4 148 165 2.4 0 2.6 2.3 01/25/2007 17:10:00 9.4 0.4 10.3 8 9.2 0.4 10.3 8 9.1 0.5 10.3 7.6 149 3 150 165 2.5 0 2.8 2.3 01/25/2007 17:20:00 9.6 0.5 10.7 8 9.4 0.4 10.3 8 9.3 0.5 10.7 7.6 148 2 151 165 2.4 0 2.6 2.3 01/25/2007 17:30:00 10 0.4 10.7 8.8 9.7 0.4 10.7 8.8 9.7 0.4 10.7 8.8 150 3 151 165 2.4 0 2.6 2.3 01/25/2007 17:40:00 10 0.4 10.7 8.8 9.8 0.4 10.7 8.8 9.8 0.4 10.7 8.8 150 3 148 165 2.4 0 2.6 2.3 01/25/2007 17:50:00 9.6 0.4 10.7 8.4 9.4 0.4 10.7 8.4 9.5 0.4 10.7 8.4 151 4 148 165 2.4 0 2.6 2.3 01/25/2007 18:00:00 8.1 0.5 9.5 6.8 7.9 0.5 9.1 6.8 7.9 0.6 9.5 6.1 153 4 157 165 2.3 0 2.6 2.1 01/25/2007 18:10:00 7.7 0.4 8.8 6.8 7.6 0.4 8.4 6.5 7.8 0.4 8.8 6.5 150 3 145 165 2.3 0 2.6 2.3 01/25/2007 18:20:00 8.7 0.7 10.3 7.6 8.5 0.7 10.3 7.6 8.5 0.7 10.3 7.2 148 2 148 165 2.3 0 2.6 2.3 01/25/2007 18:30:00 10 0.4 11.1 8.4 9.9 0.4 10.7 8.8 9.8 0.4 10.7 8.4 149 2 148 165 2.4 0 2.6 2.3 01/25/2007 18:40:00 11.3 0.7 12.6 9.5 11.2 0.6 12.2 9.1 10.9 0.6 12.2 9.1 148 3 151 165 2.4 0 2.6 2.3 01/25/2007 18:50:00 11.9 0.4 13 10.7 11.7 0.4 13 10.7 11.7 0.4 12.6 9.9 149 4 151 165 2.4 0 2.6 2.3 01/25/2007 19:00:00 11.7 0.6 13.3 10.3 11.6 0.6 13 9.9 11.4 0.6 13 9.9 148 3 147 165 2.4 0 2.6 2.3 01/25/2007 19:10:00 12.8 0.6 14.1 11.1 12.7 0.6 14.1 11.1 12.4 0.7 13.7 10.7 148 3 147 165 2.4 0 2.6 2.3 01/25/2007 19:20:00 13.6 0.6 14.9 11.8 13.5 0.6 14.9 11.8 13.2 0.6 15.3 11.5 148 3 148 165 2.4 0 2.6 2.3 01/25/2007 19:30:00 13.7 0.7 15.3 11.8 13.6 0.7 15.3 11.8 13.3 0.7 14.9 11.5 149 6 148 165 2.4 0 2.6 2.3 01/25/2007 19:40:00 12.5 0.6 14.1 10.3 12.5 0.6 14.1 10.3 12.2 0.7 13.7 10.3 150 4 153 165 2.3 0 2.6 2.3 01/25/2007 19:50:00 12.4 0.6 13.7 10.7 12.4 0.5 13.7 10.3 12 0.6 13 10.3 147 3 148 165 2.3 0 2.6 2.1 01/25/2007 20:00:00 11.9 0.7 13.7 9.9 11.8 0.7 13.3 10.3 11.7 0.7 13.3 9.9 148 9 154 165 2.3 0 2.6 2.1 01/25/2007 20:10:00 11.6 0.6 13.3 9.9 11.4 0.7 13 9.5 11.4 0.7 13 9.5 150 9 151 165 2.2 0 2.6 2.1 01/25/2007 20:20:00 12.4 0.7 13.7 10.3 12.2 0.7 14.1 9.9 12.1 0.7 14.1 9.9 150 9 154 165 2.2 0 2.3 2.1 01/25/2007 20:30:00 13.2 0.9 15.3 11.1 13 0.9 14.9 11.1 12.8 0.9 14.9 10.7 148 9 156 165 2.1 0 2.3 2.1 01/25/2007 20:40:00 14.5 0.6 16.1 12.6 14.3 0.6 15.6 12.2 14.3 0.7 16.1 12.2 149 9 151 165 2.3 0 2.6 2.1 01/25/2007 20:50:00 14.5 0.7 16.1 12.2 14.4 0.7 15.6 12.2 14.2 0.8 16.4 11.8 149 9 151 165 2.2 0 2.6 2.1 01/25/2007 21:00:00 14.9 0.6 16.4 12.6 14.8 0.6 16.1 12.6 14.7 0.6 16.4 13 149 6 148 165 2.2 0 2.6 2.1 01/25/2007 21:10:00 15.4 0.7 16.8 13.3 15.3 0.7 16.8 13.3 15.1 0.8 16.8 12.6 149 9 145 165 2.1 0 2.3 2.1 01/25/2007 21:20:00 15.9 0.9 17.6 13.3 15.6 0.8 17.2 13.3 15.7 0.9 17.6 13.3 148 7 153 165 2.1 0 2.3 2.1 01/25/2007 21:30:00 15.2 0.8 16.8 12.6 15 0.8 16.8 12.6 14.9 0.8 16.8 12.6 148 7 149 165 2.1 0 2.3 2.1 01/25/2007 21:40:00 15.3 0.7 17.2 12.6 15.1 0.6 16.8 13 15 0.8 17.2 12.6 148 8 150 165 2.1 0 2.3 2.1 01/25/2007 21:50:00 15.1 0.8 17.2 12.2 14.9 0.8 16.8 12.2 14.8 0.8 16.4 12.2 148 4 145 165 2.1 0 2.3 1.8 01/25/2007 22:00:00 15.5 0.7 17.2 13.3 15.3 0.7 17.2 13.3 15.3 0.7 17.6 13.3 148 6 147 165 2.1 0 2.3 1.8 01/25/2007 22:10:00 15.5 0.7 17.2 13.3 15.3 0.7 17.2 13 15.3 0.7 16.8 13.3 148 7 153 165 2.1 0 2.3 1.8 01/25/2007 22:20:00 16.4 0.6 17.9 14.1 16.1 0.7 17.6 14.1 16.2 0.7 17.9 14.1 150 7 153 165 2.1 0 2.3 2.1 01/25/2007 22:30:00 16.2 0.6 17.6 14.1 16 0.5 17.2 14.1 16 0.7 17.6 14.1 149 6 154 165 2.1 0 2.3 1.8 01/25/2007 22:40:00 16.2 0.8 17.9 14.1 15.9 0.8 17.2 14.1 16 0.8 17.9 14.1 149 11 156 165 2.1 0 2.3 1.8 01/25/2007 22:50:00 15.3 0.6 16.8 13 15 0.6 16.8 13 15.1 0.7 16.8 13.3 151 5 154 165 2 0 2.3 1.8 01/25/2007 23:00:00 14.2 0.7 15.6 12.6 13.9 0.7 15.6 12.2 14 0.7 16.1 12.2 151 7 154 165 2 0 2.3 1.8 01/25/2007 23:10:00 13.1 0.6 15.3 11.8 12.8 0.6 15.3 11.5 13 0.5 14.9 11.5 149 14 154 165 2 0 2.3 1.8 01/25/2007 23:20:00 12.7 0.9 15.3 10.7 12.4 0.9 15.3 10.3 12.6 0.9 15.3 10.7 149 12 122 165 2 0 2.3 1.8 01/25/2007 23:30:00 13 0.6 14.5 11.5 12.8 0.6 14.5 11.1 13.1 0.6 14.9 11.5 149 15 148 165 2 0 2.3 1.8 01/25/2007 23:40:00 12 0.8 13.7 9.9 11.7 0.8 13.7 9.5 12.1 0.8 14.1 9.9 137 36 155 165 2 0 2.3 1.8 01/25/2007 23:50:00 12.7 1.2 15.3 9.5 12.3 1.2 15.3 9.5 12.8 1.3 15.3 9.5 141 30 107 165 2.1 0 2.6 1.8 01/26/2007 00:00:00 14.9 0.9 17.2 12.2 14.5 0.9 16.8 12.2 14.9 1 16.8 12.6 140 38 151 165 2.3 0 2.6 2.1 01/26/2007 00:10:00 13.6 0.9 16.4 11.5 13.2 0.9 16.1 11.1 13.8 0.8 16.4 11.8 138 39 165 165 2.3 0 2.6 2.1 01/26/2007 00:20:00 13.5 0.8 15.6 11.5 13.1 0.8 15.3 10.7 13.9 0.7 15.6 11.8 138 30 124 165 2.2 0 2.6 2.1 01/26/2007 00:30:00 13.5 0.8 15.6 11.1 13.1 0.8 14.9 10.7 13.6 0.8 15.6 11.8 136 45 157 165 2.2 0 2.6 2.1 01/26/2007 00:40:00 14 1 16.4 11.5 13.6 1 16.4 11.1 14 1.1 16.8 11.1 137 38 136 165 2.3 0 2.6 2.1 01/26/2007 00:50:00 15.6 1 18.3 13 15.2 1 17.9 13 15.8 1.1 18.7 13.3 142 22 158 165 2.3 0 2.8 2.1 01/26/2007 01:00:00 14.3 1 17.2 12.6 14 0.9 16.8 11.8 14.1 1 17.2 12.2 147 10 151 165 2.1 0 2.3 1.8 01/26/2007 01:10:00 14.8 0.7 16.4 12.6 14.5 0.7 16.1 12.6 14.6 0.8 17.2 13 147 11 141 165 2 0 2.3 1.8 01/26/2007 01:20:00 15 0.7 17.2 13.3 14.7 0.7 16.8 13 14.9 0.7 16.8 13.3 148 6 150 165 2 0 2.3 1.8 01/26/2007 01:30:00 14 0.9 15.6 11.5 13.7 0.9 15.3 10.7 13.9 1 16.1 11.1 149 6 147 165 2 0 2.3 1.8 01/26/2007 01:40:00 13.4 1 15.6 11.5 13.2 1 15.3 11.5 13.3 1.1 16.1 11.5 149 6 152 165 2 0 2.3 1.8 01/26/2007 01:50:00 13.1 1.1 15.6 9.1 12.7 1.1 15.3 8.8 13.1 1.1 15.3 9.5 142 26 148 165 2.1 0 2.3 1.8 01/26/2007 02:00:00 11.1 0.8 13.3 8.8 10.8 0.8 13 8.8 11.4 0.8 13.3 9.1 147 29 165 165 2.2 0 2.6 1.8 01/26/2007 02:10:00 12.6 1.1 15.6 9.5 12.2 1 14.9 9.5 12.7 1 15.3 9.9 147 35 169 165 2.1 0 2.6 1.8 01/26/2007 02:20:00 14.4 1.1 17.2 11.8 14 1 16.4 11.8 14.6 1.1 17.6 12.2 157 38 168 165 2.4 0 2.8 2.3 01/26/2007 02:30:00 14.2 0.9 16.8 11.8 13.8 0.9 16.1 11.5 14.4 1 17.2 12.6 161 23 184 165 2.4 0 2.6 2.3 01/26/2007 02:40:00 15.6 1 17.9 12.6 15.1 0.9 17.2 11.8 15.8 1 18.3 13 158 38 169 165 2.4 0 2.8 2.3 01/26/2007 02:50:00 15.1 0.8 17.2 12.6 14.7 0.8 16.4 12.6 15.5 0.8 17.6 13 157 33 169 165 2.5 0 2.8 2.3 01/26/2007 03:00:00 15.5 1.3 18.3 12.2 15.1 1.2 17.6 11.8 15.7 1.5 18.7 12.2 157 36 177 165 2.4 0 2.8 2.3 01/26/2007 03:10:00 13.8 0.8 16.1 11.1 13.4 0.8 15.3 11.1 13.9 0.9 16.4 11.5 146 32 174 165 2.4 0 2.8 2.3 01/26/2007 03:20:00 12.7 0.9 16.4 10.7 12.4 0.9 16.1 10.7 12.8 0.9 16.4 10.7 136 33 151 165 2.4 0 2.6 2.3 01/26/2007 03:30:00 14.7 1.2 17.6 11.5 14.4 1.2 17.2 11.5 14.9 1.2 17.9 11.8 137 38 88 165 2.4 0 2.8 2.3 01/26/2007 03:40:00 14.2 1.1 17.6 11.5 13.9 1 17.2 11.5 14.4 1.1 17.2 11.8 138 36 160 165 2.4 0 2.6 2.3 01/26/2007 03:50:00 14.2 1 17.6 12.2 13.9 0.9 17.2 11.8 14.5 0.8 17.2 11.8 134 35 148 165 2.3 0 2.6 2.3 01/26/2007 04:00:00 15.4 1.5 19.9 11.8 15.1 1.5 19.5 11.5 15.6 1.5 19.9 12.6 142 43 107 165 2.5 0.1 2.8 2.3 01/26/2007 04:10:00 15.8 1.2 19.1 11.8 15.5 1.2 19.1 11.8 15.9 1.3 19.5 13 143 43 167 165 2.6 0 2.8 2.3 01/26/2007 04:20:00 14.5 1.1 17.6 11.8 14.1 1.1 16.8 11.5 14.6 1.2 17.9 11.8 138 43 65 165 2.5 0.1 2.8 2.3 01/26/2007 04:30:00 14.3 1.5 17.9 10.3 14 1.4 17.6 9.9 14.3 1.6 17.9 10.3 134 38 25 165 2.6 0 2.8 2.3 01/26/2007 04:40:00 13.6 1.3 16.4 9.9 13.4 1.3 16.4 10.3 13.6 1.3 16.8 10.3 148 15 153 165 2.4 0.1 2.8 2.3 01/26/2007 04:50:00 14.3 0.7 16.4 12.6 14.1 0.7 16.4 12.2 14.2 0.7 16.4 12.2 149 9 150 165 2.3 0 2.6 2.1 01/26/2007 05:00:00 14.2 0.8 16.4 11.5 13.9 0.9 16.1 11.1 14.3 0.8 16.4 11.8 140 36 154 165 2.2 0 2.6 2.1 01/26/2007 05:10:00 13.9 1 16.1 11.5 13.6 1 15.6 11.1 14 1 16.1 11.5 148 38 79 165 2.1 0 2.3 1.8 01/26/2007 05:20:00 13.9 1.3 17.6 10.7 13.7 1.3 16.8 10.3 14 1.3 16.8 11.1 138 41 26 165 2.1 0 2.3 1.8 01/26/2007 05:30:00 15.3 1.1 17.9 11.5 15 1.1 17.9 11.5 15.3 1.1 18.3 12.2 138 38 57 165 2.2 0 2.6 2.1 01/26/2007 05:40:00 16.2 1 19.5 14.1 15.9 1 19.5 14.1 16.4 1.1 19.9 12.6 141 43 166 165 2 0 2.3 1.8 01/26/2007 05:50:00 17.6 1 19.9 14.1 17.3 1 19.5 14.1 17.6 1 19.9 13.7 146 43 153 165 2 0 2.3 1.8 01/26/2007 06:00:00 18 1 20.2 15.3 17.8 1 20.2 14.9 18.1 1.1 20.6 14.1 141 43 124 165 2.1 0 2.6 1.8 01/26/2007 06:10:00 16.5 1.1 19.9 14.1 16.3 1.1 19.5 13.7 16.6 1 19.5 14.1 134 51 141 165 2.2 0 2.3 2.1 01/26/2007 06:20:00 16.8 1.5 19.9 13.3 16.6 1.5 20.2 13.3 16.9 1.5 20.2 13 126 39 165 165 2.2 0 2.6 1.8 01/26/2007 06:30:00 18.6 0.8 20.6 16.4 18.4 0.8 20.2 16.1 18.6 1 20.6 16.1 140 51 165 165 2 0.1 2.3 1.8 01/26/2007 06:40:00 18.9 1.2 21.8 14.9 18.5 1.1 21.4 14.5 18.9 1.2 21.4 14.9 142 51 166 165 2.1 0.1 2.6 1.8 01/26/2007 06:50:00 20.2 1.4 23.7 16.8 19.7 1.3 22.9 16.1 20.4 1.5 24 16.4 154 41 165 165 2.4 0.1 2.8 2.3 01/26/2007 07:00:00 18.6 1.2 22.1 15.6 18.1 1.2 22.1 15.3 18.8 1.3 22.6 16.4 153 41 166 165 2.4 0 2.8 2.1 01/26/2007 07:10:00 19.1 1.1 21.8 16.1 18.6 1.1 21.4 15.6 19.2 1.1 22.6 16.4 166 22 173 165 2.3 0 2.6 2.1 01/26/2007 07:20:00 19.7 1.2 22.9 16.8 19.1 1.1 22.9 16.4 19.9 1.2 23.3 16.8 166 22 167 165 2.5 0 2.8 2.3 01/26/2007 07:30:00 18.7 1.2 21.8 14.9 18.3 1.1 21.4 14.9 18.9 1.2 22.1 15.3 159 33 166 165 2.4 0 2.8 2.3 01/26/2007 07:40:00 19.2 1.3 21.8 16.1 18.7 1.3 21.8 15.3 19.5 1.2 22.6 16.8 170 23 170 165 2.1 0.2 2.6 1.8 01/26/2007 07:50:00 17.6 1.3 20.6 13.7 17.2 1.3 19.9 13.7 17.8 1.4 21 13.7 161 33 173 165 2.3 0 2.6 2.1 01/26/2007 08:00:00 19.3 1.3 22.6 16.1 18.9 1.2 21.4 16.1 19.6 1.4 22.9 15.6 166 26 169 165 2.4 0 2.6 2.3 01/26/2007 08:10:00 19.9 1.1 22.6 17.2 19.4 1 22.1 17.2 20.2 1.2 23.3 17.2 156 35 171 165 2.3 0 2.6 2.1 01/26/2007 08:20:00 21.2 1.4 24 17.2 20.8 1.4 24 16.8 21.6 1.6 25.6 17.2 146 45 165 165 2.3 0 2.6 2.1 01/26/2007 08:30:00 19.5 2.6 27.9 15.6 19.1 2.6 27.5 15.6 19.7 2.7 28.7 14.9 167 16 167 165 2.1 0 2.6 1.8 01/26/2007 08:40:00 21 1.7 26.8 17.9 20.6 1.7 25.6 17.9 21.1 1.7 26.8 17.9 162 26 165 165 1.7 0 1.8 1.4 01/26/2007 08:50:00 20.2 1.6 24.4 16.1 19.9 1.6 24.4 16.1 20.2 1.5 24.4 16.8 162 26 173 165 1.7 0 1.8 1.6 01/26/2007 09:00:00 20 1.3 22.9 15.6 19.8 1.3 22.9 15.3 20.1 1.4 23.7 16.1 167 23 173 165 1.8 0 1.8 1.6 01/26/2007 09:10:00 18.1 1.1 21 15.3 17.7 1.1 20.6 15.3 18.2 1.1 21.4 15.3 163 30 165 165 1.8 0 1.8 1.6 01/26/2007 09:20:00 17.7 1.1 21 14.1 17.3 1.2 20.6 14.1 18 1.2 21 13.7 165 29 166 165 1.9 0 2.3 1.8 01/26/2007 09:30:00 17.6 1.1 21.4 14.5 17.1 1.1 20.6 14.5 17.9 1 20.6 14.9 164 24 185 165 2 0 2.3 1.8 01/26/2007 09:40:00 18.2 1.2 21.8 15.3 17.8 1.1 21.4 14.5 18.3 1.2 21.4 14.1 168 17 181 165 1.9 0 2.3 1.6 01/26/2007 09:50:00 17.6 1 19.9 14.9 17.2 1 19.9 14.5 17.8 1 20.2 15.3 158 28 171 165 2.1 0 2.3 1.8 01/26/2007 10:00:00 17 1.2 19.9 14.1 16.6 1.2 19.5 13.7 17.3 1.3 20.6 14.1 167 27 166 165 2.2 0 2.6 1.8 01/26/2007 10:10:00 20.1 1.5 23.3 13.7 19.6 1.4 23.3 13.7 20.1 1.5 23.3 14.1 160 30 171 165 1.7 0.1 2.3 1.4 01/26/2007 10:20:00 17.1 2.7 22.1 10.3 16.6 2.6 21.8 10.3 17.1 2.6 21.8 12.6 171 26 170 165 1.4 0 1.6 1.4 01/26/2007 10:30:00 13.8 1.2 17.6 11.1 13.4 1.2 17.2 11.1 14 1.2 17.6 11.1 175 15 178 165 1.5 0 1.6 1.4 01/26/2007 10:40:00 15.7 1.6 19.1 11.1 15.4 1.6 18.7 10.7 16 1.7 18.7 10.7 162 29 171 165 1.5 0 1.6 1.4 01/26/2007 10:50:00 17.2 1.2 20.2 14.1 16.9 1.3 19.5 14.1 17.4 1.2 20.2 14.5 167 22 177 165 1.4 0 1.6 1.4 01/26/2007 11:00:00 15.1 1 17.9 12.6 14.6 0.9 17.2 12.2 15.3 1 18.7 13.3 171 8 160 165 1.4 0 1.6 1.4 01/26/2007 11:10:00 16.6 1.2 19.9 13.7 16.1 1.2 19.1 13 16.8 1.3 20.2 14.1 172 9 166 165 1.5 0 1.8 1.4 01/26/2007 11:20:00 15.2 0.9 17.2 11.8 14.8 0.9 16.4 11.5 15.5 1 17.9 12.6 164 26 178 165 1.5 0 1.6 1.4 01/26/2007 11:30:00 16.5 1.6 20.6 13.3 16.1 1.5 20.2 12.6 16.8 1.6 21 13.7 164 28 180 165 1.7 0.1 1.8 1.6 01/26/2007 11:40:00 17.9 1.3 21 13.7 17.3 1.2 20.6 13.3 18.1 1.3 21.4 14.5 162 29 176 165 2 0 2.3 1.8 01/26/2007 11:50:00 17.6 1.1 20.6 14.9 17.1 1.1 19.9 14.5 17.8 1.2 21 14.9 170 15 177 165 2.1 0 2.3 1.8 01/26/2007 12:00:00 18.3 1 20.6 15.3 17.7 0.9 19.9 14.9 18.6 1 20.6 14.9 169 18 177 165 2.1 0 2.3 1.8 01/26/2007 12:10:00 16.8 1.1 19.1 14.1 16.2 1.1 18.7 13.7 17 1.2 19.9 14.1 170 21 169 165 2 0 2.3 1.8 01/26/2007 12:20:00 16.8 0.8 18.7 13.3 16.2 0.8 17.9 13.3 17.2 1 19.5 13.7 169 15 172 165 2 0 2.3 1.8 01/26/2007 12:30:00 15.7 1.4 19.1 12.6 15.2 1.4 18.3 12.6 15.8 1.6 19.1 12.6 164 23 175 165 1.6 0.2 1.8 1.4 01/26/2007 12:40:00 11.7 1.2 14.9 7.6 11.3 1.2 14.5 7.2 11.8 1.2 15.3 8 176 11 175 165 1.4 0 1.6 1.4 01/26/2007 12:50:00 11.2 1.9 16.8 7.6 11 1.9 16.4 7.6 11.4 1.9 17.2 7.6 183 8 191 165 1.7 0.1 1.8 1.4 01/26/2007 13:00:00 11.6 1.7 15.3 7.2 11.4 1.7 14.9 7.2 11.8 1.7 15.6 7.6 184 9 188 165 2 0 2.3 1.8 01/26/2007 13:10:00 11.3 1.5 14.9 7.2 11.1 1.5 14.5 6.1 11.3 1.5 15.3 7.2 182 19 192 165 2.1 0 2.3 1.8 01/26/2007 13:20:00 10.4 1.2 13.3 7.6 10.3 1.2 13.3 7.6 10.6 1.2 14.5 8 185 11 182 165 2.3 0 2.3 2.1 01/26/2007 13:30:00 9.4 1 11.8 6.1 9.2 1 11.8 6.1 9.6 1 12.2 7.6 181 8 185 165 2.3 0 2.6 2.1 01/26/2007 13:40:00 10.7 1.5 14.1 6.8 10.6 1.4 14.1 6.8 10.9 1.5 14.5 7.2 192 7 199 165 2.2 0 2.6 1.8 01/26/2007 13:50:00 14 1.5 18.3 9.9 13.8 1.5 18.3 9.9 14.2 1.6 17.9 10.3 187 8 190 165 2 0 2.3 1.8 01/26/2007 14:00:00 14.3 1.7 19.1 10.3 14.1 1.7 18.7 10.3 14.5 1.8 20.2 10.3 182 8 193 165 2 0 2.3 1.8 01/26/2007 14:10:00 19 2.3 25.6 13.7 18.8 2.1 24.8 12.6 19.1 2.3 25.6 13.7 183 16 186 165 2.1 0 2.3 1.8 01/26/2007 14:20:00 16.8 1.8 22.9 11.8 16.6 1.7 22.1 11.5 17.1 1.7 22.6 11.1 180 17 194 165 2.1 0 2.3 1.8 01/26/2007 14:30:00 17.9 1.7 22.6 13.7 17.5 1.5 21.4 13.7 18 1.7 22.6 13.3 180 18 179 165 2.1 0 2.3 1.8 01/26/2007 14:40:00 16.9 2 21.8 12.2 16.6 1.9 21.4 12.2 17.2 1.8 22.6 13.3 182 12 182 165 2.1 0 2.3 1.8 01/26/2007 14:50:00 14.5 2.4 20.2 9.5 14.5 2.5 21 9.9 14.8 2.4 20.6 10.7 186 11 194 165 2.1 0 2.3 1.8 01/26/2007 15:00:00 13 1.6 17.2 9.5 12.7 1.5 16.4 9.1 13.2 1.6 17.2 9.1 182 12 190 165 2.1 0 2.3 1.8 01/26/2007 15:10:00 13.3 1.5 16.8 9.9 13 1.4 16.4 9.5 13.4 1.5 16.8 9.5 181 11 186 165 2.3 0 2.6 2.1 01/26/2007 15:20:00 12.7 1.4 16.4 9.1 12.4 1.4 15.6 9.5 12.9 1.4 18.3 9.5 179 12 182 165 2.3 0 2.6 2.1 01/26/2007 15:30:00 12.8 1.6 16.4 8.8 12.6 1.5 16.1 9.1 13.1 1.5 16.8 9.9 181 16 178 165 2.3 0 2.6 2.1 01/26/2007 15:40:00 13.6 1.4 16.4 9.1 13.5 1.4 16.8 9.1 13.7 1.3 16.8 9.9 191 10 190 165 2.2 0 2.3 1.8 01/26/2007 15:50:00 13.6 2 17.6 8 13.5 1.9 17.2 8 13.6 2.3 17.9 9.1 191 10 190 165 2.1 0 2.6 2.1 01/26/2007 16:00:00 11.9 2 16.8 6.8 11.9 2 16.8 6.8 12 2.1 18.3 7.2 195 8 187 165 2.1 0 2.3 1.8 01/26/2007 16:10:00 8.6 1.7 12.2 4.6 8.7 1.7 12.2 4.6 8.7 1.6 12.6 4.9 194 10 181 165 2 0.1 2.3 1.8 01/26/2007 16:20:00 8.7 1.5 13.3 5.3 8.7 1.5 12.6 4.9 9 1.4 13.3 5.7 189 12 190 165 1.9 0 2.1 1.8 01/26/2007 16:30:00 6.6 1.1 9.5 3.4 6.5 1 9.1 3.4 6.6 1 9.1 3.8 182 16 195 165 1.9 0 2.1 1.8 01/26/2007 16:40:00 7.6 1.2 11.5 4.2 7.5 1.1 11.1 4.2 7.8 1 10.3 5.7 183 11 192 165 1.9 0 2.1 1.8 01/26/2007 16:50:00 7.2 0.9 9.5 4.2 7 0.8 9.1 4.2 7.4 0.8 9.9 4.9 179 8 182 165 1.8 0 1.8 1.6 01/26/2007 17:00:00 5.5 1.1 8.4 3 5.4 1.1 7.6 2.6 5.8 1.1 8.8 3.4 184 11 165 165 1.8 0 1.8 1.6 01/26/2007 17:10:00 3.8 0.6 6.1 2.6 3.8 0.7 5.7 2.3 3.9 0.6 6.5 2.6 198 12 207 165 1.8 0 1.8 1.6 01/26/2007 17:20:00 5.3 0.8 8.4 3.4 5.3 0.8 8 3.4 5.6 0.9 8.4 3.8 196 9 186 165 1.8 0 1.8 1.6 01/26/2007 17:30:00 6.6 0.8 9.1 4.2 6.6 0.8 8.8 4.2 6.8 0.8 9.1 4.9 187 8 207 165 1.8 0 1.8 1.6 01/26/2007 17:40:00 5.8 0.9 8 3.4 5.7 0.9 8 3.8 5.9 0.8 8 3.8 195 8 193 165 1.8 0 1.8 1.6 01/26/2007 17:50:00 6.4 1.1 9.5 4.2 6.4 1.1 9.9 4.2 6.5 1.1 9.5 4.2 194 10 189 165 2 0 2.3 1.8 01/26/2007 18:00:00 6.5 0.9 9.1 4.6 6.5 0.9 8.8 4.9 6.7 1 9.1 4.6 193 10 196 165 2 0.1 2.3 1.8 01/26/2007 18:10:00 7.4 1.1 10.3 4.9 7.4 1 10.3 5.3 7.6 1 10.7 5.3 191 9 198 165 2 0 2.3 1.8 01/26/2007 18:20:00 5.5 0.6 7.6 4.2 5.3 0.5 7.2 3.8 5.7 0.5 7.2 4.6 168 12 186 165 1.7 0 2.1 1.6 01/26/2007 18:30:00 7 1 9.1 5.3 6.7 0.9 8.8 4.9 7.2 1 9.5 5.3 156 17 146 165 1.6 0 1.8 1.4 01/26/2007 18:40:00 9.6 1 11.5 7.2 9.3 0.9 11.1 6.8 9.6 1 11.8 6.8 149 27 165 165 1.5 0 1.6 1.4 01/26/2007 18:50:00 8.9 0.7 10.3 6.8 8.6 0.6 9.9 6.5 9 0.6 10.7 6.8 151 23 156 165 1.5 0 1.6 1.4 01/26/2007 19:00:00 9.3 0.8 11.5 7.2 9 0.8 11.1 7.2 9.4 0.7 11.1 7.2 143 32 50 165 1.6 0 1.8 1.6 01/26/2007 19:10:00 10.7 0.8 12.2 8.8 10.3 0.7 12.2 8.4 10.8 0.7 12.6 8.8 150 32 129 165 1.7 0 1.8 1.6 01/26/2007 19:20:00 11.5 0.6 13 9.5 11.1 0.5 12.6 9.1 11.6 0.6 13 9.9 162 19 174 165 1.7 0 1.8 1.6 01/26/2007 19:30:00 10.4 1.9 13.3 6.5 10 1.9 13 6.5 10.6 1.9 13.3 6.5 170 23 165 165 1.7 0 1.8 1.4 01/26/2007 19:40:00 6.1 0.7 8 4.6 5.9 0.7 7.6 4.2 6.3 0.8 8.4 4.2 178 7 171 165 1.5 0.1 1.6 1.4 01/26/2007 19:50:00 4.4 0.5 6.1 2.6 4.2 0.5 5.7 2.3 4.7 0.5 6.1 3 186 5 179 165 1.4 0.1 1.6 1.4 01/26/2007 20:00:00 4.2 0.4 5.3 3 4.1 0.4 4.9 3 4.5 0.5 5.3 3.4 190 4 193 165 1.4 0 1.6 1.4 01/26/2007 20:10:00 5.7 0.6 7.2 4.2 5.5 0.6 7.2 3.8 5.8 0.5 7.2 4.6 174 14 180 165 1.4 0 1.6 1.1 01/26/2007 20:20:00 6.1 0.8 8.4 3.8 6 0.8 8 3.8 6.2 0.8 8.4 3.4 191 7 188 165 1.2 0 1.4 0.9 01/26/2007 20:30:00 6.6 0.6 8.4 5.3 6.5 0.6 8 5.3 6.8 0.7 8.8 4.9 188 5 180 165 1.3 0 1.6 1.1 01/26/2007 20:40:00 5.7 0.8 8.4 4.2 5.6 0.8 8.4 3.8 5.8 0.8 8 4.2 193 8 179 165 1.3 0 1.6 1.1 01/26/2007 20:50:00 8.2 1.7 12.2 5.3 8 1.6 11.8 4.9 8.4 1.7 12.2 5.3 183 7 166 165 1.1 0 1.4 0.9 01/26/2007 21:00:00 11.2 1.1 13.3 8 10.9 1 13 8 11.3 1 13.7 9.1 178 6 178 165 1.4 0 1.6 1.4 01/26/2007 21:10:00 10 1 12.6 8.4 9.7 1 12.2 8 10.3 0.9 13 8.4 170 9 169 165 1.2 0 1.4 1.1 01/26/2007 21:20:00 8.1 0.6 9.9 6.8 7.7 0.5 9.5 6.8 8.2 0.5 9.5 7.2 170 8 169 165 1.3 0 1.4 1.1 01/26/2007 21:30:00 8.7 0.5 9.9 7.2 8.3 0.5 9.5 7.2 8.8 0.6 9.9 7.2 166 12 173 165 1.4 0 1.6 1.4 01/26/2007 21:40:00 9.6 1 11.8 7.6 9.3 1 11.8 7.2 9.7 1.1 12.2 7.6 156 23 157 165 1.4 0 1.8 1.4 01/26/2007 21:50:00 9.6 0.8 14.1 8 9.4 0.8 14.1 8 9.7 0.8 13.3 8 151 19 150 165 1.6 0.1 1.8 1.4 01/26/2007 22:00:00 10.3 0.9 13 8.8 10.1 0.9 13 8 10.5 0.8 13 8.8 150 22 92 165 1.3 0 1.6 1.4 01/26/2007 22:10:00 8.8 0.7 11.5 7.6 8.7 0.6 11.1 7.6 8.8 0.7 11.1 6.5 150 7 152 165 1.2 0 1.4 1.1 01/26/2007 22:20:00 9.2 1 12.2 7.2 9 1 11.8 7.2 9.1 1.1 12.2 7.2 149 16 119 165 1.2 0 1.4 0.9 01/26/2007 22:30:00 10.1 0.6 11.5 8.4 9.8 0.6 11.8 8 10.2 0.6 12.2 8 146 20 152 165 1.3 0 1.4 1.1 01/26/2007 22:40:00 10 0.7 11.8 7.6 9.7 0.7 11.5 7.6 10.2 0.7 11.8 8.4 148 17 150 165 1.2 0 1.4 0.9 01/26/2007 22:50:00 9.3 1 12.2 7.2 9.1 1 11.8 7.2 9.3 1 12.2 7.2 149 22 151 165 1 0 1.4 0.9 01/26/2007 23:00:00 9.4 1.3 12.2 6.8 9.1 1.3 11.8 6.5 9.3 1.2 12.6 7.2 163 23 167 165 1.1 0 1.4 0.9 01/26/2007 23:10:00 10.3 0.7 12.6 8.4 10 0.8 12.2 8 10 0.8 12.2 8 152 33 150 165 1.1 0 1.4 0.9 01/26/2007 23:20:00 10.1 1.2 13.7 8 9.8 1.2 13.7 7.6 10.3 1.1 13.3 8.4 147 28 86 165 1.3 0 1.4 1.1 01/26/2007 23:30:00 7.7 0.4 9.1 6.8 7.5 0.4 9.1 6.5 7.8 0.4 9.1 6.8 152 19 165 165 1.2 0 1.4 0.9 01/26/2007 23:40:00 6.9 0.4 8 6.1 6.7 0.4 7.6 5.7 7 0.4 8 5.7 154 12 152 165 1.3 0 1.4 1.1 01/26/2007 23:50:00 8.7 1.1 11.5 6.5 8.5 1.1 11.1 6.1 9 1.2 12.2 6.5 151 23 166 165 1.2 0 1.4 1.1 01/27/2007 00:00:00 9.2 0.9 11.1 7.6 8.9 0.9 10.7 6.8 9.3 1 11.5 7.2 148 22 165 165 1.2 0 1.4 0.9 01/27/2007 00:10:00 9.1 0.8 10.7 7.2 8.7 0.7 10.3 7.2 9.2 0.8 11.1 7.6 149 28 157 165 1.2 0 1.4 0.9 01/27/2007 00:20:00 8.4 0.5 9.5 6.5 8 0.5 9.1 6.1 8.3 0.5 9.5 6.5 152 20 151 165 1.2 0 1.4 1.1 01/27/2007 00:30:00 9.3 0.6 11.5 8 9 0.6 11.5 7.6 9.2 0.6 11.1 7.6 151 17 43 165 1.3 0 1.4 1.1 01/27/2007 00:40:00 10.2 0.5 11.8 8.4 9.8 0.5 11.5 8 10.4 0.6 11.8 8.8 161 28 166 165 1.3 0 1.6 1.1 01/27/2007 00:50:00 10.4 1 13 8.4 10.1 1 13 8.4 10.4 1 13 8.8 146 32 158 165 1.2 0 1.4 1.1 01/27/2007 01:00:00 9.3 0.3 10.3 8.4 9 0.3 9.9 8 9.2 0.4 10.3 8 154 22 154 165 1.2 0 1.4 0.9 01/27/2007 01:10:00 9.3 0.8 11.8 7.6 9.1 0.8 11.5 7.2 9.2 0.8 11.8 7.6 152 11 156 165 1.2 0 1.4 1.1 01/27/2007 01:20:00 10.7 0.7 12.6 8.8 10.5 0.6 12.6 8.8 10.8 0.7 12.6 8.4 149 16 154 165 1.4 0 1.6 1.4 01/27/2007 01:30:00 9.7 0.6 11.1 7.2 9.5 0.6 11.1 7.2 9.8 0.6 11.1 8 152 12 155 165 1.4 0 1.6 1.4 01/27/2007 01:40:00 9.2 0.9 11.1 6.8 9.1 0.9 11.1 6.8 9.1 1 11.1 6.8 149 3 150 165 1.4 0 1.6 1.4 01/27/2007 01:50:00 12.1 0.7 14.5 10.3 11.9 0.6 14.5 10.3 12 0.7 14.5 10.3 149 3 150 165 1.5 0 1.6 1.4 01/27/2007 02:00:00 13 0.8 15.3 11.1 12.8 0.8 14.9 10.7 13.1 1 15.6 10.3 149 7 140 165 1.6 0 1.8 1.6 01/27/2007 02:10:00 12 1 14.5 9.5 11.7 1 14.1 9.1 12.2 1 14.9 9.9 142 30 116 165 1.6 0 1.8 1.4 01/27/2007 02:20:00 10.9 0.7 12.6 9.5 10.7 0.7 12.2 9.5 11.1 0.7 13 9.9 142 24 154 165 1.7 0 1.8 1.4 01/27/2007 02:30:00 13 1.2 14.5 9.9 12.7 1.2 14.1 9.5 13.1 1.2 15.3 9.9 149 11 151 165 1.7 0 1.8 1.6 01/27/2007 02:40:00 14.1 0.6 15.6 12.2 13.8 0.6 15.3 11.5 14.3 0.6 16.1 12.6 151 9 156 165 1.6 0 1.8 1.4 01/27/2007 02:50:00 13.6 0.5 14.9 12.6 13.4 0.5 14.5 12.2 13.9 0.7 15.3 12.2 151 9 156 165 1.5 0 1.6 1.4 01/27/2007 03:00:00 12.9 0.5 14.1 11.8 12.6 0.4 13.7 11.5 12.9 0.6 14.5 11.5 152 3 153 165 1.5 0 1.6 1.4 01/27/2007 03:10:00 14.2 0.6 15.6 12.2 13.9 0.6 15.3 12.2 14.3 0.8 15.6 12.2 152 4 155 165 1.5 0 1.6 1.4 01/27/2007 03:20:00 14.6 0.5 16.1 12.6 14.3 0.5 16.1 12.6 14.8 0.6 16.4 13 150 13 153 165 1.6 0 1.8 1.4 01/27/2007 03:30:00 14.5 0.4 15.6 13.3 14.2 0.4 15.3 12.6 14.6 0.6 16.1 12.2 152 5 150 165 1.6 0 1.8 1.6 01/27/2007 03:40:00 14.2 0.6 15.6 12.6 14 0.6 15.6 12.2 14.3 0.8 16.4 12.2 151 9 157 165 1.6 0 1.8 1.4 01/27/2007 03:50:00 15 0.5 16.8 13.7 14.7 0.5 16.1 13.7 15.1 0.6 17.2 13.3 150 12 130 165 1.6 0 1.8 1.6 01/27/2007 04:00:00 15 0.6 16.4 13.3 14.7 0.6 16.1 13 15 0.6 16.4 13.3 151 4 149 165 1.6 0 1.6 1.4 01/27/2007 04:10:00 15.5 0.7 16.8 13.3 15.2 0.6 16.8 13.3 15.5 0.8 17.2 13 149 6 147 165 1.6 0 1.8 1.6 01/27/2007 04:20:00 16.2 0.7 17.6 14.1 15.9 0.7 17.2 13.7 16.3 0.8 17.6 13.7 150 6 154 165 1.7 0 1.8 1.6 01/27/2007 04:30:00 16 0.7 17.9 13.7 15.9 0.7 17.6 13.7 16.1 0.9 18.3 13.3 149 7 154 165 1.7 0 1.8 1.6 01/27/2007 04:40:00 15.9 1 17.9 13.3 15.7 1.1 17.9 13 15.7 1.2 18.3 12.6 149 6 148 165 1.7 0 1.8 1.6 01/27/2007 04:50:00 16.1 0.7 17.9 14.1 15.9 0.7 17.6 13.7 15.9 0.9 17.9 13.3 149 7 153 165 1.7 0 1.8 1.6 01/27/2007 05:00:00 15.4 0.5 16.4 13.3 15.1 0.5 16.4 13.3 15.2 0.6 16.4 13 150 10 151 165 1.6 0 1.8 1.6 01/27/2007 05:10:00 14.7 0.6 15.6 12.2 14.5 0.6 15.6 12.2 14.6 0.6 16.1 13 150 5 148 165 1.6 0 1.8 1.4 01/27/2007 05:20:00 14.8 0.8 17.2 12.6 14.6 0.8 16.8 12.6 14.7 0.8 16.8 12.6 149 9 149 165 1.5 0 1.6 1.4 01/27/2007 05:30:00 14.9 0.7 16.8 13 14.6 0.7 16.8 13 14.9 0.8 16.8 12.2 150 6 142 165 1.5 0 1.6 1.4 01/27/2007 05:40:00 15.6 1 17.9 12.2 15.4 1 17.6 12.6 15.6 0.9 17.6 13 148 12 153 165 1.4 0 1.6 1.4 01/27/2007 05:50:00 15 0.8 17.6 12.6 14.7 0.8 17.2 12.6 15.2 0.7 17.6 13 148 16 153 165 1.5 0 1.6 1.4 01/27/2007 06:00:00 13.3 0.6 14.9 11.1 13.1 0.6 14.5 11.1 13.2 0.6 14.9 11.1 151 4 153 165 1.5 0 1.6 1.4 01/27/2007 06:10:00 15.8 1 17.9 12.6 15.5 1 17.6 12.2 15.6 1.1 18.3 13 148 9 153 165 1.7 0 1.8 1.4 01/27/2007 06:20:00 15.7 0.9 17.9 13 15.4 0.9 17.6 12.6 15.8 1 17.9 13 149 10 148 165 1.7 0 1.8 1.6 01/27/2007 06:30:00 14.5 0.8 16.4 12.2 14.2 0.8 16.1 11.8 14.5 0.9 16.8 11.8 147 16 158 165 1.5 0 1.6 1.4 01/27/2007 06:40:00 12.8 0.7 14.5 11.1 12.5 0.7 14.1 11.1 12.9 0.7 14.5 11.1 152 4 150 165 1.5 0 1.6 1.4 01/27/2007 06:50:00 13.6 0.9 15.6 11.1 13.4 0.9 15.6 10.7 13.5 1 16.1 10.3 150 9 150 165 1.5 0 1.8 1.4 01/27/2007 07:00:00 14 0.8 16.8 11.8 13.8 0.8 16.8 11.8 13.9 0.9 16.8 11.8 149 7 139 165 1.6 0 1.8 1.4 01/27/2007 07:10:00 16.7 1 19.9 14.5 16.5 1 19.5 14.1 16.7 1.1 19.9 14.5 146 7 151 165 1.3 0 1.6 1.1 01/27/2007 07:20:00 16.7 1.1 19.5 14.1 16.5 1.1 19.9 14.1 16.6 1.3 19.5 14.1 149 7 149 165 1.5 0 1.6 1.4 01/27/2007 07:30:00 15.7 1 18.3 13.7 15.4 1 17.9 13.3 15.6 1.1 18.7 12.2 148 10 149 165 1.6 0 1.8 1.4 01/27/2007 07:40:00 16.1 2 21 11.5 15.9 1.9 20.6 11.5 16 2 21 11.5 147 7 153 165 1.7 0 1.8 1.6 01/27/2007 07:50:00 19 0.8 21 16.4 18.7 0.8 20.6 15.6 18.9 1 21 15.6 146 12 151 165 1.7 0 1.8 1.6 01/27/2007 08:00:00 18 1.5 21.4 14.9 17.7 1.4 21 14.9 18 1.5 21.4 14.9 147 5 146 165 1.5 0 1.6 1.4 01/27/2007 08:10:00 16.7 0.9 18.7 14.1 16.5 0.9 18.3 14.1 16.6 1 18.7 13.3 147 5 135 165 1.5 0 1.6 1.4 01/27/2007 08:20:00 16.5 1 19.5 13.7 16.2 1 18.7 13.3 16.6 1.1 19.1 13.7 146 15 150 165 1.4 0.1 1.6 1.1 01/27/2007 08:30:00 17.8 1.8 21.8 13.7 17.6 1.9 21.8 13.3 17.7 1.9 21.8 13.3 145 10 147 165 1.2 0 1.4 0.9 01/27/2007 08:40:00 17 1.5 19.9 13.3 16.9 1.5 20.2 13.3 17 1.5 19.9 13.7 144 11 144 165 1.2 0 1.4 0.9 01/27/2007 08:50:00 18 1 20.6 15.6 18 1.1 20.6 15.6 17.9 1.1 21 14.5 147 6 139 165 1.3 0 1.6 1.1 01/27/2007 09:00:00 17.6 1.3 21.4 13.7 17.7 1.4 21.4 14.1 17.5 1.4 21 14.5 146 9 149 165 1.3 0 1.4 1.1 01/27/2007 09:10:00 16.5 0.8 17.9 13.7 16.5 0.8 18.3 14.5 16.3 1 18.3 13 146 9 148 165 1.3 0 1.4 1.1 01/27/2007 09:20:00 18 1.6 21.4 13.7 18.1 1.6 21.8 13.7 17.9 1.6 21.8 13.7 142 7 130 165 1.4 0 1.6 1.4 01/27/2007 09:30:00 18.1 1 20.6 15.3 18.1 1 20.2 15.3 17.9 1.2 20.2 14.9 144 6 150 165 1.4 0 1.6 1.4 01/27/2007 09:40:00 18.2 1.2 21 15.3 18.1 1.2 21 15.3 18 1.4 21 14.5 143 6 144 165 1.3 0 1.4 1.4 01/27/2007 09:50:00 18.1 1.1 20.6 15.6 18.1 1.1 21 15.3 18 1.3 21.4 14.9 144 5 142 165 1.3 0 1.4 1.1 01/27/2007 10:00:00 18.5 1.4 21.4 15.3 18.4 1.4 21.4 14.9 18.2 1.7 22.1 13.7 140 7 145 165 1.2 0 1.4 0.9 01/27/2007 10:10:00 18.2 1.3 21 13.7 18.1 1.3 21 14.1 18.1 1.4 21.4 13.3 140 8 145 165 1 0 1.4 0.9 01/27/2007 10:20:00 16.1 1 18.3 13.3 16 1 18.3 13.3 16 1.1 19.1 13 147 6 146 165 0.9 0 1.4 0.9 01/27/2007 10:30:00 15.4 1.3 18.7 11.8 15.3 1.2 18.7 12.2 15.1 1.4 17.9 11.1 139 8 139 165 0.9 0 1.1 0.9 01/27/2007 10:40:00 15.2 1.3 18.3 11.8 15 1.3 18.3 11.8 15.1 1.3 19.1 12.2 144 11 150 165 0.8 0 1.1 0.9 01/27/2007 10:50:00 14.3 1.5 17.9 11.1 14.2 1.5 17.9 10.7 14 1.7 18.3 10.3 135 8 139 165 0.9 0 1.1 0.9 01/27/2007 11:00:00 14.9 1.3 17.9 11.1 14.8 1.3 17.9 10.7 14.5 1.4 17.9 10.7 136 9 138 165 0.8 0.1 1.1 0.7 01/27/2007 11:10:00 14.3 1.3 16.8 10.7 14.1 1.3 17.2 10.7 14.3 1.3 17.2 11.5 145 4 136 165 0.8 0 0.9 0.7 01/27/2007 11:20:00 11.4 1.1 14.1 8.8 11.4 1.2 14.1 8.8 11.2 1.2 14.9 8 131 10 136 165 0.9 0 1.1 0.9 01/27/2007 11:30:00 13.6 1.3 16.8 10.3 13.6 1.3 17.2 9.9 13.3 1.3 16.4 9.9 128 8 126 165 0.9 0 1.1 0.9 01/27/2007 11:40:00 11.9 1.4 15.3 9.1 12 1.4 15.6 9.1 11.8 1.4 15.6 9.1 126 6 130 165 0.8 0 1.1 0.9 01/27/2007 11:50:00 12.1 1.2 14.5 9.1 12.3 1.2 14.9 9.1 11.7 1.4 16.1 8.4 120 6 124 165 0.8 0 1.1 0.7 01/27/2007 12:00:00 10.3 1.2 14.1 7.6 10.5 1.2 14.9 7.2 10 1.2 13.7 6.8 116 8 112 165 0.9 0 1.1 0.9 01/27/2007 12:10:00 12.5 1.1 15.3 9.5 12.7 1.1 15.6 9.5 12.1 1.3 15.3 8.8 113 6 106 165 0.9 0 1.1 0.9 01/27/2007 12:20:00 11.8 1.3 14.5 8.4 12 1.3 14.9 8.8 11 1.5 14.5 7.2 112 6 102 165 0.9 0 1.1 0.9 01/27/2007 12:30:00 12.1 1.3 15.3 7.6 12.4 1.4 16.1 7.6 11.4 1.5 14.9 6.8 113 7 112 165 1 0 1.1 0.9 01/27/2007 12:40:00 11.4 1.3 15.3 7.2 11.6 1.3 15.3 6.8 10.9 1.4 14.9 7.6 114 7 119 165 1 0 1.1 0.9 01/27/2007 12:50:00 10.5 1.2 13.7 7.6 10.8 1.2 14.9 7.6 10.2 1.3 14.1 6.8 102 8 105 165 1 0 1.1 0.9 01/27/2007 13:00:00 10.5 1.5 13.7 6.5 10.8 1.5 13.7 6.5 10 1.5 13 6.5 98 6 81 165 1 0 1.1 0.9 01/27/2007 13:10:00 9.5 1.5 13 5.7 9.9 1.5 13.7 6.1 8.9 1.3 12.2 5.3 96 8 87 165 1 0 1.4 0.9 01/27/2007 13:20:00 10.7 1.2 13.3 7.2 11.1 1.2 13.7 7.2 10.4 1.2 13.3 7.2 90 7 85 165 1.1 0 1.4 0.9 01/27/2007 13:30:00 10.7 1.1 13 7.6 11.1 1.1 13.3 7.6 10.5 1.2 13.3 7.6 84 5 82 165 1.1 0 1.4 0.9 01/27/2007 13:40:00 10.6 1.3 13.7 8 10.9 1.3 14.1 7.6 10.4 1.4 13.7 7.2 83 7 93 165 1.1 0 1.4 0.9 01/27/2007 13:50:00 10 1.2 12.6 6.8 10.4 1.2 13 7.2 10 1.2 12.6 7.2 86 8 94 165 1.1 0 1.4 0.9 01/27/2007 14:00:00 10.6 1.1 13.3 8 10.9 1.1 13.7 8.4 10.5 1.2 13.3 7.6 84 5 91 165 1.2 0 1.4 0.9 01/27/2007 14:10:00 10.8 1.3 14.5 7.6 11.1 1.3 14.9 7.6 10.7 1.4 14.5 7.6 84 8 91 165 1.2 0 1.4 0.9 01/27/2007 14:20:00 11.4 1.3 14.5 7.6 11.7 1.3 14.9 8 11.1 1.3 14.9 7.6 92 6 80 165 1.2 0 1.4 1.1 01/27/2007 14:30:00 10.8 1.5 14.9 6.8 11.2 1.5 14.9 6.8 10.7 1.5 14.9 7.2 90 7 92 165 1.3 0 1.4 1.1 01/27/2007 14:40:00 12 1.3 15.3 8.4 12.4 1.3 15.6 8.4 12 1.5 15.3 8.8 92 0 93 165 1.4 0 1.6 1.4 01/27/2007 14:50:00 12.1 1.2 14.5 9.1 12.4 1.2 14.9 9.5 12 1.2 15.3 8.8 92 0 92 165 1.4 0 1.6 1.4 01/27/2007 15:00:00 12.4 1.7 16.1 8.4 12.8 1.7 16.4 8.8 12.5 1.7 16.1 8.4 92 0 92 165 1.5 0 1.8 1.4 01/27/2007 15:10:00 13 1.7 17.2 9.1 13.4 1.7 17.6 8.8 12.8 1.7 17.2 8.8 95 4 97 165 1.9 0.1 2.3 1.6 01/27/2007 15:20:00 15.5 1.6 19.5 10.3 15.9 1.6 19.9 10.7 14.6 1.7 19.1 9.9 100 8 98 165 2.1 0.2 2.6 1.6 01/27/2007 15:30:00 15.4 1 17.6 12.6 15.7 1.1 18.7 13 14.8 1.2 18.7 11.1 105 5 101 165 2.6 0 2.8 2.3 01/27/2007 15:40:00 14.7 1.1 17.2 11.8 14.9 1.1 17.6 11.8 14.2 1.4 17.9 10.3 109 6 121 165 2.8 0 3 2.6 01/27/2007 15:50:00 14.2 1.4 18.7 10.3 14.3 1.4 17.9 10.3 13.7 1.5 17.6 9.5 118 6 119 165 3 0 3.3 2.8 01/27/2007 16:00:00 15.3 1.4 19.5 11.8 15.4 1.3 19.5 12.2 15 1.5 19.1 11.5 124 5 122 165 3.1 0 3.3 2.8 01/27/2007 16:10:00 15.7 1.3 19.1 11.8 15.7 1.3 18.7 11.8 15.5 1.3 18.7 11.1 131 7 132 165 3.2 0 3.5 3 01/27/2007 16:20:00 15.4 1.3 19.1 11.8 15.3 1.3 19.1 11.8 15 1.5 18.7 11.5 137 6 136 165 3.2 0 3.5 3 01/27/2007 16:30:00 16.9 1.2 19.9 13.3 16.9 1.2 19.5 13.3 16.8 1.2 19.9 13 140 6 140 165 3.2 0 3.5 3 01/27/2007 16:40:00 16.1 0.9 18.3 13.7 16 0.8 18.3 13.7 15.9 0.9 18.3 13.7 142 6 139 165 3.1 0 3.3 2.8 01/27/2007 16:50:00 15.3 1.3 18.7 12.6 15.3 1.3 18.7 12.2 15.1 1.3 18.7 11.8 145 4 143 165 3 0 3.3 2.8 01/27/2007 17:00:00 14 1 16.4 11.8 13.9 1 16.8 11.8 13.9 1 16.8 10.7 145 4 149 165 3 0 3.3 2.8 01/27/2007 17:10:00 14.4 1 16.4 11.8 14.3 1 16.1 11.8 14.3 1.1 16.4 11.1 144 4 145 165 2.9 0 3 2.6 01/27/2007 17:20:00 15.2 0.9 17.9 13 15.1 1 17.9 13 14.9 1 17.6 12.2 145 4 143 165 2.7 0 3 2.6 01/27/2007 17:30:00 14 0.9 16.4 11.8 13.8 0.9 16.4 11.8 13.8 0.9 16.1 11.1 147 3 147 165 2.7 0 2.8 2.6 01/27/2007 17:40:00 12.8 0.8 14.9 11.1 12.7 0.8 14.9 11.1 12.6 0.9 14.9 10.7 148 3 151 165 2.6 0 2.8 2.6 01/27/2007 17:50:00 13 0.5 14.1 11.5 12.9 0.5 14.1 11.1 12.8 0.7 14.1 10.7 148 3 147 165 2.6 0 2.8 2.6 01/27/2007 18:00:00 11.9 1.1 14.1 9.5 11.8 1.1 14.1 9.1 11.7 1.2 14.1 8.4 150 5 149 165 2.6 0.1 2.8 2.3 01/27/2007 18:10:00 10.4 1 12.6 8.4 10.3 1 12.6 8 10.3 1 13 7.6 151 4 150 165 2.4 0 2.8 2.3 01/27/2007 18:20:00 9.2 0.7 11.1 7.6 9 0.6 10.7 7.6 8.9 0.7 10.3 6.8 152 2 151 165 2.4 0 2.6 2.3 01/27/2007 18:30:00 9 0.5 10.7 7.6 8.9 0.5 10.3 7.6 8.8 0.5 10.3 7.6 149 4 151 165 2.4 0 2.8 2.3 01/27/2007 18:40:00 10.3 1.4 12.6 7.2 10.2 1.4 12.6 7.6 10.1 1.3 12.6 7.6 147 4 145 165 2.5 0 2.8 2.3 01/27/2007 18:50:00 11.4 0.6 13 9.5 11.4 0.7 13 9.5 11.2 0.8 13 8.8 147 3 150 165 2.4 0 2.6 2.3 01/27/2007 19:00:00 11.5 1 13.3 9.1 11.4 1 13.3 9.1 11.1 1.1 13.3 8 146 5 147 165 2.4 0 2.6 2.3 01/27/2007 19:10:00 11.7 0.6 13 9.9 11.6 0.6 13 9.9 11.4 0.7 13 9.5 148 3 148 165 2.4 0 2.6 2.3 01/27/2007 19:20:00 12.6 0.6 14.1 11.1 12.5 0.6 14.1 10.7 12.3 0.8 14.1 10.3 148 3 140 165 2.3 0 2.6 2.3 01/27/2007 19:30:00 12.6 0.7 14.1 10.3 12.5 0.7 14.5 10.7 12.4 0.8 14.1 9.9 148 3 144 165 2.3 0 2.6 2.3 01/27/2007 19:40:00 11.8 0.6 13.3 10.3 11.7 0.6 13.3 9.9 11.5 0.7 13.3 9.5 148 3 157 165 2.3 0 2.6 2.1 01/27/2007 19:50:00 11 0.7 12.6 8 10.8 0.8 12.6 8.4 10.7 0.7 12.6 8.8 150 3 154 165 2.3 0 2.6 2.1 01/27/2007 20:00:00 11 0.7 12.6 8.8 10.8 0.7 12.2 8.8 10.9 0.7 12.6 9.1 151 4 155 165 2.3 0 2.6 2.1 01/27/2007 20:10:00 11.6 0.6 13 9.5 11.4 0.6 13 9.5 11.4 0.8 13 8.8 152 2 151 165 2.2 0 2.3 2.1 01/27/2007 20:20:00 11.2 0.5 12.2 9.1 11.1 0.5 12.2 9.1 11 0.6 12.2 9.1 152 2 148 165 2.2 0 2.3 2.1 01/27/2007 20:30:00 10.9 0.9 12.6 8.8 10.8 0.9 12.2 8.4 10.7 0.8 12.6 8.4 150 3 153 165 2.1 0 2.3 1.8 01/27/2007 20:40:00 8.4 0.8 9.9 6.5 8.2 0.7 9.9 6.1 8.2 0.7 9.9 6.5 153 4 151 165 2.1 0 2.3 1.8 01/27/2007 20:50:00 8.2 0.4 9.1 7.2 8 0.4 9.1 6.8 8.1 0.4 8.8 6.5 150 3 150 165 2.1 0 2.3 2.1 01/27/2007 21:00:00 8.4 0.5 9.5 6.8 8.2 0.4 9.1 6.5 8.2 0.5 9.5 6.5 148 3 147 165 2.1 0 2.3 2.1 01/27/2007 21:10:00 7.4 0.6 8.8 5.7 7.2 0.6 8.4 5.7 7.3 0.6 8.8 5.7 149 3 150 165 2.1 0 2.3 2.1 01/27/2007 21:20:00 5.8 0.4 6.8 4.9 5.6 0.4 6.5 4.9 5.9 0.4 6.8 4.9 154 4 153 165 2.1 0 2.3 1.8 01/27/2007 21:30:00 5.3 0.5 6.5 4.2 5.1 0.5 6.1 4.2 5.5 0.5 6.5 4.2 157 8 162 165 2 0 2.3 1.8 01/27/2007 21:40:00 4.2 0.4 4.9 3 4 0.4 4.9 2.6 4.4 0.4 4.9 3 158 12 153 165 2 0 2.3 1.8 01/27/2007 21:50:00 3.7 0.3 4.2 3 3.6 0.3 4.2 3 3.9 0.3 4.6 3 150 5 152 165 2 0 2.1 1.8 01/27/2007 22:00:00 4.3 0.5 5.3 3.4 4.2 0.6 5.7 3.4 4.4 0.6 5.7 3.4 141 3 140 165 1.9 0 2.1 1.8 01/27/2007 22:10:00 5.5 0.4 6.8 4.2 5.5 0.5 6.8 4.2 5.6 0.4 6.8 3.8 142 5 136 165 1.9 0 2.1 1.8 01/27/2007 22:20:00 6.3 0.4 7.2 4.9 6.2 0.5 7.2 4.9 6.2 0.5 8 4.6 140 6 136 165 1.9 0 2.1 1.8 01/27/2007 22:30:00 5 0.5 6.1 3.4 4.9 0.5 6.1 3.4 5 0.6 6.1 3.8 140 5 136 165 1.9 0 2.1 1.8 01/27/2007 22:40:00 3.8 0.5 4.9 1.9 3.7 0.5 4.9 2.3 4 0.5 5.3 2.6 148 7 157 165 1.9 0 2.1 1.8 01/27/2007 22:50:00 4.2 0.5 5.7 3 4.1 0.5 5.7 3 4.2 0.5 5.3 3 142 7 135 165 1.9 0 2.1 1.8 01/27/2007 23:00:00 5.5 0.9 7.2 3.4 5.5 0.9 7.2 3.4 5.5 1 7.2 3.4 135 6 135 165 1.9 0 2.1 1.8 01/27/2007 23:10:00 7.2 0.5 8.4 5.7 7 0.5 8 5.3 7 0.5 8 5.3 139 5 144 165 1.9 0 1.8 1.8 01/27/2007 23:20:00 7.3 0.8 9.5 5.7 7.2 0.7 9.5 5.7 7.2 0.7 9.1 5.7 147 5 151 165 1.8 0 1.8 1.8 01/27/2007 23:30:00 8.6 0.6 9.5 6.5 8.4 0.6 9.1 6.5 8.4 0.7 9.5 6.1 150 4 147 165 1.9 0 2.1 1.8 01/27/2007 23:40:00 9.3 0.3 10.3 8.4 9 0.3 9.9 8 9.2 0.4 10.3 8 152 3 151 165 1.9 0 2.1 1.8 01/27/2007 23:50:00 8.4 0.6 9.9 7.2 8.2 0.6 9.5 6.8 8.4 0.6 9.9 6.8 152 2 151 165 1.9 0 2.1 1.8 01/28/2007 00:00:00 7.1 0.5 8 5.7 6.8 0.5 8 5.3 7.1 0.5 8 5.7 154 2 151 165 1.9 0 2.1 1.6 01/28/2007 00:10:00 6.5 0.4 7.6 4.9 6.2 0.4 7.2 4.9 6.7 0.5 7.6 5.3 155 3 153 165 1.9 0 2.1 1.8 01/28/2007 00:20:00 6.1 0.5 7.2 4.6 5.9 0.5 7.2 4.6 6.4 0.5 7.6 5.3 156 9 155 165 1.9 0 2.1 1.8 01/28/2007 00:30:00 4.7 0.5 5.7 3.4 4.6 0.6 5.7 3.4 5.1 0.6 6.5 3.4 158 12 152 165 1.8 0 2.1 1.6 01/28/2007 00:40:00 3.7 0.6 4.9 2.3 3.5 0.5 4.6 1.9 3.9 0.5 4.9 2.3 160 9 156 165 1.8 0 1.8 1.6 01/28/2007 00:50:00 2.8 0.3 3.4 1.9 2.7 0.3 3.4 1.9 3 0.3 3.4 2.3 165 5 165 165 1.7 0 1.8 1.6 01/28/2007 01:00:00 3.3 0.3 4.2 2.3 3.1 0.3 3.8 2.3 3.4 0.3 4.2 2.6 163 8 160 165 1.7 0 1.8 1.6 01/28/2007 01:10:00 3.1 0.4 4.2 2.3 3 0.4 4.2 2.3 3.2 0.3 4.2 2.3 150 7 152 165 1.7 0 1.8 1.6 01/28/2007 01:20:00 3 0.4 3.8 1.9 2.8 0.3 3.8 1.9 3.1 0.4 3.8 1.9 156 5 154 165 1.7 0 1.8 1.6 01/28/2007 01:30:00 2.5 0.2 3 1.9 2.3 0.2 2.6 1.9 2.6 0.2 3 1.9 164 9 165 165 1.7 0 1.8 1.6 01/28/2007 01:40:00 2.2 0.5 3 1.1 2 0.6 3 0.7 2.4 0.5 3 1.1 166 8 170 165 1.6 0 1.8 1.4 01/28/2007 01:50:00 1.6 0.4 2.3 0.7 1.4 0.4 2.3 0.7 1.7 0.4 2.3 0.7 188 13 175 165 1.6 0 1.8 1.6 01/28/2007 02:00:00 1.9 0.3 2.6 1.1 1.7 0.3 2.6 1.1 2.2 0.3 3 1.5 180 12 192 165 1.6 0 1.8 1.4 01/28/2007 02:10:00 2 0.3 2.6 1.5 1.9 0.3 2.6 1.1 2.4 0.2 3 1.9 150 11 135 165 1.5 0 1.6 1.4 01/28/2007 02:20:00 2.6 0.3 3.4 1.9 2.5 0.3 3.4 1.5 2.8 0.3 3.4 2.3 134 3 135 165 1.7 0 1.8 1.6 01/28/2007 02:30:00 2.2 0.3 3 1.5 2 0.4 3 1.1 2.4 0.3 3 1.5 143 6 145 165 1.7 0 1.8 1.6 01/28/2007 02:40:00 3.6 0.5 4.6 2.6 3.5 0.5 4.6 2.3 3.7 0.4 4.6 2.6 138 7 139 165 1.6 0 1.8 1.6 01/28/2007 02:50:00 4.2 0.3 4.9 3.4 4 0.2 4.9 3.4 4.2 0.3 4.9 3.8 135 4 144 165 1.6 0 1.8 1.6 01/28/2007 03:00:00 4.8 0.2 5.3 4.2 4.6 0.2 5.3 3.8 4.7 0.3 5.3 3.4 142 2 145 165 1.6 0 1.8 1.6 01/28/2007 03:10:00 4.7 0.2 5.3 3.8 4.5 0.2 4.9 3.8 4.7 0.3 5.3 3.8 149 3 145 165 1.6 0 1.6 1.6 01/28/2007 03:20:00 4.5 0.4 5.3 3 4.3 0.4 4.9 3 4.4 0.4 5.3 3.4 151 0 151 165 1.5 0 1.6 1.4 01/28/2007 03:30:00 4 0.5 5.3 2.6 3.8 0.5 4.9 2.6 4 0.5 5.7 3 151 0 151 165 1.5 0 1.8 1.4 01/28/2007 03:40:00 3.2 0.9 4.6 1.5 2.9 0.9 4.6 0.7 3 1.1 4.9 0.7 151 0 151 165 1.5 0 1.6 1.4 01/28/2007 03:50:00 3 0.9 4.6 1.5 2.7 0.9 4.6 1.1 2.9 1 4.6 1.1 151 0 151 165 1.5 0 1.6 1.4 01/28/2007 04:00:00 4.5 0.3 5.3 3.8 4.3 0.4 4.9 3.4 4.6 0.4 5.3 3.8 151 0 151 165 1.5 0 1.8 1.4 01/28/2007 04:10:00 4 0.6 5.3 2.6 3.8 0.6 5.3 2.3 4 0.7 5.3 2.6 151 0 151 165 1.5 0 1.6 1.4 01/28/2007 04:20:00 4 0.3 4.6 3.4 3.6 0.3 4.2 3 3.8 0.3 4.6 3 151 0 151 165 1.5 0 1.8 1.4 01/28/2007 04:30:00 3.9 0.5 4.9 2.6 3.7 0.5 4.9 1.9 4 0.4 5.3 3 151 0 151 165 1.5 0 1.6 1.4 01/28/2007 04:40:00 3.7 0.5 5.3 2.6 3.4 0.6 4.9 1.9 3.6 0.6 5.3 2.3 151 0 151 165 1.5 0 1.6 1.4 01/28/2007 04:50:00 3.5 0.4 4.6 2.6 3.1 0.4 4.2 2.3 3.3 0.4 4.6 2.3 151 0 151 165 1.4 0 1.8 1.4 01/28/2007 05:00:00 2.3 0.4 3 1.5 1.9 0.4 2.6 0.7 2.1 0.4 3 1.1 151 0 151 165 1.4 0 1.8 1.4 01/28/2007 05:10:00 2.2 0.3 3 1.1 1.8 0.4 2.6 0.7 2.2 0.4 3 1.1 151 0 151 165 1.4 0 1.6 1.4 01/28/2007 05:20:00 2.7 0.6 4.2 1.5 2.3 0.6 3.8 1.1 2.4 0.6 3.8 1.1 151 0 151 165 1.4 0 1.6 1.4 01/28/2007 05:30:00 3 0.6 4.2 1.9 2.7 0.6 3.8 1.5 2.7 0.7 4.2 1.5 151 0 151 165 1.4 0 1.6 1.4 01/28/2007 05:40:00 1.9 0.5 3 1.1 1.5 0.5 2.6 0.7 1.7 0.5 3 0.7 151 0 151 165 1.5 0 1.6 1.4 01/28/2007 05:50:00 0.8 0.5 1.9 0.4 0.6 0.4 1.9 0.4 0.7 0.4 1.9 0.4 151 0 151 165 1.5 0 1.6 1.4 01/28/2007 06:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 151 0 165 165 1.5 0 1.6 1.4 01/28/2007 06:10:00 0.5 0.3 2.3 0.4 0.4 0.2 1.9 0.4 0.4 0.2 1.5 0.4 151 0 151 165 1.5 0 1.6 1.4 01/28/2007 06:20:00 0.9 0.6 2.3 0.4 0.7 0.5 1.9 0.4 0.8 0.7 2.6 0.4 151 0 151 165 1.5 0 1.8 1.4 01/28/2007 06:30:00 3 0.4 3.8 1.9 2.8 0.4 3.4 1.5 3 0.3 3.4 2.3 151 0 151 165 1.5 0 1.8 1.4 01/28/2007 06:40:00 2.7 0.4 3.4 1.5 2.5 0.4 3.4 1.1 2.7 0.4 3.4 1.9 151 0 151 165 1.4 0 1.6 1.4 01/28/2007 06:50:00 2.6 0.5 4.2 1.5 2.3 0.6 3.8 0.7 2.6 0.5 3.8 1.5 151 0 151 165 1.4 0 1.6 1.4 01/28/2007 07:00:00 2.3 0.3 3 1.5 1.9 0.4 2.6 1.1 2.3 0.4 3 1.1 151 0 151 165 1.4 0 1.6 1.4 01/28/2007 07:10:00 2.4 0.6 3.8 1.1 1.9 0.6 3.4 0.4 2.2 0.5 3.4 0.7 151 0 151 165 1.4 0 1.6 1.4 01/28/2007 07:20:00 2.6 0.4 3.4 1.9 2.2 0.4 3.4 1.1 2.2 0.4 3 1.1 151 0 151 165 1.4 0 1.6 1.4 01/28/2007 07:30:00 2.9 0.3 3.4 2.3 2.4 0.3 3 1.9 2.5 0.4 3.4 1.1 151 0 151 165 1.4 0 1.6 1.4 01/28/2007 07:40:00 2.9 0.3 3.8 2.3 2.5 0.3 3.4 1.9 2.9 0.3 3.4 2.3 151 0 151 165 1.4 0 1.6 1.4 01/28/2007 07:50:00 2.5 0.2 3 1.9 2.1 0.3 3 1.5 2.4 0.3 3 1.9 151 0 151 165 1.3 0 1.4 0.9 01/28/2007 08:00:00 4 0.5 4.9 3 3.6 0.5 4.6 2.6 4 0.5 4.9 2.6 151 0 151 165 1.3 0 1.4 1.1 01/28/2007 08:10:00 3.7 0.2 4.2 3.4 3.3 0.2 3.8 2.6 3.5 0.2 4.2 3 151 0 151 165 1.2 0 1.4 0.9 01/28/2007 08:20:00 3.9 0.4 4.9 2.6 3.5 0.4 4.6 2.6 3.8 0.4 4.9 2.6 151 0 151 165 1.2 0 1.4 0.9 01/28/2007 08:30:00 3.2 0.3 3.8 2.6 3 0.3 3.8 2.3 3.1 0.3 3.8 2.6 151 0 151 165 1.1 0 1.4 0.9 01/28/2007 08:40:00 2.3 0.3 3 1.5 1.9 0.3 2.6 1.1 2 0.4 3 1.1 151 0 151 165 1.2 0 1.4 1.1 01/28/2007 08:50:00 3.1 0.4 3.8 2.3 2.9 0.4 3.8 1.9 3.2 0.3 3.8 2.6 151 0 151 165 1.2 0 1.4 1.1 01/28/2007 09:00:00 2.7 0.3 3.4 1.9 2.5 0.3 3 1.5 2.5 0.3 3 1.9 151 0 151 165 1.3 0 1.6 1.1 01/28/2007 09:10:00 1.8 0.4 2.6 0.7 1.4 0.5 2.6 0.4 1.6 0.4 2.3 0.4 151 0 151 165 1.4 0 1.6 1.4 01/28/2007 09:20:00 0.5 0.2 1.1 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 151 0 151 165 1.4 0 1.6 1.4 01/28/2007 09:30:00 0.4 0.1 0.7 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 151 0 151 165 1.5 0 1.6 1.4 01/28/2007 09:40:00 0.5 0.2 1.1 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 151 0 151 165 1.6 0 1.8 1.4 01/28/2007 09:50:00 0.4 0.2 1.1 0.4 0.4 0 0.4 0.4 0.4 0.1 1.1 0.4 147 7 151 165 2 0.1 2.3 1.6 01/28/2007 10:00:00 0.6 0.3 1.5 0.4 0.5 0.2 1.1 0.4 0.5 0.2 1.1 0.4 122 5 115 165 2.4 0.1 2.6 1.8 01/28/2007 10:10:00 0.7 0.3 1.5 0.4 0.5 0.2 1.1 0.4 0.4 0 0.4 0.4 113 4 106 165 2.6 0 3 2.1 01/28/2007 10:20:00 1.7 0.4 2.3 1.1 1.4 0.4 2.3 0.4 1.4 0.6 2.3 0.4 114 6 116 165 2.9 0 3 2.3 01/28/2007 10:30:00 1.9 0.3 2.3 0.7 1.8 0.3 2.3 0.7 1.9 0.2 2.3 1.1 111 4 115 165 2.7 0 3 2.1 01/28/2007 10:40:00 1.2 0.5 2.3 0.4 0.8 0.4 2.3 0.4 1.4 0.5 2.6 0.4 47 36 39 165 2.9 0.2 3.5 2.3 01/28/2007 10:50:00 0.4 0.1 1.1 0.4 0.4 0 0.7 0.4 0.4 0.2 1.1 0.4 19 7 31 165 3.5 0.3 4.8 3.3 01/28/2007 11:00:00 0.7 0.5 2.6 0.4 0.5 0.4 1.9 0.4 0.9 0.6 2.3 0.4 22 10 1 165 4.8 0.2 5.2 4.3 01/28/2007 11:10:00 2.1 0.3 2.6 1.5 1.3 0.3 2.3 0.7 2.3 0.3 3 1.9 8 4 3 165 4.3 0.1 4.8 4.3 01/28/2007 11:20:00 1.4 0.5 2.3 0.4 1.1 0.4 1.9 0.4 2 0.5 3 0.7 29 13 11 165 4 0.3 4.5 3.5 01/28/2007 11:30:00 0.7 0.4 1.9 0.4 0.5 0.3 1.9 0.4 1.4 0.6 2.6 0.4 48 13 47 165 3.5 0.4 4.3 3 01/28/2007 11:40:00 0.7 0.5 1.9 0.4 0.6 0.4 1.9 0.4 1.2 0.5 2.3 0.4 126 28 151 165 3.7 0.4 4.3 2.8 01/28/2007 11:50:00 1.6 0.4 2.6 0.7 1.2 0.5 2.3 0.4 1.8 0.3 2.6 1.1 121 11 113 165 2.2 0.3 2.8 1.8 01/28/2007 12:00:00 1.6 0.4 2.6 0.7 1.3 0.6 2.6 0.4 1.6 0.6 3 0.4 80 19 54 165 1.9 0 2.3 1.6 01/28/2007 12:10:00 2.7 0.4 3.8 1.9 2.7 0.4 3.8 1.9 3 0.5 4.2 1.9 33 13 23 165 2.1 0.5 3 1.4 01/28/2007 12:20:00 2.8 0.7 3.8 0.7 2.7 0.7 3.8 0.7 3.2 0.6 4.2 1.5 27 3 25 165 3.3 0.2 3.8 2.8 01/28/2007 12:30:00 0.5 0.3 1.5 0.4 0.6 0.4 1.9 0.4 0.9 0.5 2.3 0.4 77 47 84 165 4 0.3 5 3.5 01/28/2007 12:40:00 0.5 0.4 1.5 0.4 0.5 0.2 1.1 0.4 0.8 0.5 1.9 0.4 71 51 18 165 3.3 0.3 4.3 2.8 01/28/2007 12:50:00 2.3 0.3 2.6 1.5 1.8 0.4 2.6 0.7 2.5 0.4 3 1.5 4 6 10 165 4.4 0.1 4.8 4 01/28/2007 13:00:00 1.5 0.5 2.3 0.4 1.7 0.3 2.3 0.7 1.8 0.7 3 0.4 45 36 357 165 4.3 0 4.5 4 01/28/2007 13:10:00 2.4 1.4 4.6 0.4 1.8 0.7 3.8 0.4 2.8 1.3 4.9 0.4 25 38 359 165 3.1 0.4 4.3 2.6 01/28/2007 13:20:00 4.1 0.2 4.9 3.4 2.9 0.5 4.6 1.9 4.4 0.3 5.3 3.8 6 5 3 165 2.9 0 3.3 2.6 01/28/2007 13:30:00 3.7 0.2 4.2 3 3.3 0.4 4.2 2.3 4 0.3 4.6 3.4 15 4 11 165 3 0.1 3.5 2.8 01/28/2007 13:40:00 3.8 0.3 4.6 3 2.8 0.5 4.2 1.5 4 0.3 4.9 3 9 6 10 165 3 0.1 3.5 2.8 01/28/2007 13:50:00 2.1 0.9 3.8 0.4 2.1 0.8 3.4 0.4 2.4 1 4.2 0.4 25 20 18 165 3 0.1 3.5 2.8 01/28/2007 14:00:00 1.9 0.6 3 0.4 1.7 0.5 3 0.4 2.3 0.6 3.4 0.4 12 18 349 165 3.2 0.2 3.5 2.6 01/28/2007 14:10:00 3.2 0.3 4.2 2.3 2.7 0.5 3.8 1.5 3.4 0.3 4.2 2.3 13 8 12 165 2.1 0.2 2.8 1.8 01/28/2007 14:20:00 2.6 0.4 3.4 1.5 2.6 0.4 3.4 1.9 2.9 0.3 3.8 2.3 23 6 32 165 1.7 0 1.8 1.4 01/28/2007 14:30:00 1.7 0.6 2.6 0.4 2 0.5 3 0.7 1.8 0.6 2.6 0.4 59 17 38 165 1.4 0.1 1.6 1.4 01/28/2007 14:40:00 1.1 0.7 3 0.4 1.5 0.8 3 0.4 1.4 0.8 3 0.4 69 22 34 165 1.4 0 1.6 1.4 01/28/2007 14:50:00 2.5 0.6 3.8 1.1 2.7 0.5 4.2 1.5 2.9 0.6 4.2 1.5 37 17 31 165 1.4 0 1.6 0.9 01/28/2007 15:00:00 3.6 0.6 4.9 1.5 3.6 0.6 4.9 1.5 3.7 0.6 4.9 1.5 24 8 28 165 1.5 0 1.6 1.1 01/28/2007 15:10:00 2.3 0.5 3.4 1.1 2.3 0.5 3.4 0.7 2.4 0.5 3.4 1.1 26 10 28 165 1.6 0 1.8 1.1 01/28/2007 15:20:00 2 0.5 3.4 0.7 2 0.5 3.4 0.7 2.1 0.5 3.4 0.7 31 14 29 165 1.7 0 1.8 1.6 01/28/2007 15:30:00 1.9 0.8 3.8 0.4 2 0.9 3.8 0.4 1.8 0.8 3.4 0.4 70 26 94 165 1.7 0 1.8 1.6 01/28/2007 15:40:00 2.8 0.5 3.8 1.9 3 0.5 4.2 1.9 2.9 0.4 4.2 1.9 83 5 91 165 1.7 0 1.8 1.4 01/28/2007 15:50:00 2.3 0.5 3.4 1.1 2.5 0.5 3.4 1.5 2.4 0.5 3.8 1.1 77 10 63 165 1.6 0 1.8 0.9 01/28/2007 16:00:00 2.4 0.5 3.4 1.5 2.5 0.5 3.8 1.5 2.5 0.5 3.8 1.1 91 11 80 165 1.6 0 1.8 0.9 01/28/2007 16:10:00 2.7 0.4 3.8 1.9 2.9 0.4 3.8 1.9 2.8 0.4 3.8 1.5 87 6 82 165 1.6 0 1.8 1.6 01/28/2007 16:20:00 2.5 0.4 3.4 1.5 2.6 0.4 3.8 1.5 2.6 0.5 3.8 1.5 86 11 80 165 1.7 0 1.8 1.4 01/28/2007 16:30:00 2 0.5 3 1.1 2.1 0.4 3 1.1 2 0.6 3 0.7 104 8 94 165 1.6 0 1.8 1.4 01/28/2007 16:40:00 1.2 0.3 2.3 0.4 1.3 0.3 2.3 0.7 0.9 0.4 1.9 0.4 93 3 90 165 1.6 0 1.8 1.1 01/28/2007 16:50:00 2.4 0.7 3.8 1.1 2.4 0.6 3.8 1.1 2.5 0.7 3.8 0.7 121 19 128 165 1.5 0 1.8 1.4 01/28/2007 17:00:00 3.1 0.4 3.8 1.9 3 0.4 3.8 1.9 3 0.5 3.8 1.5 124 9 132 165 1.4 0 1.6 1.4 01/28/2007 17:10:00 3.4 0.4 4.2 1.9 3.3 0.4 4.2 2.3 3.4 0.4 4.2 1.9 119 7 121 165 1.3 0.1 1.6 0.9 01/28/2007 17:20:00 3.6 0.3 4.2 2.6 3.4 0.3 4.2 2.6 3.6 0.3 4.2 2.6 130 5 125 165 1.2 0.2 1.6 0.9 01/28/2007 17:30:00 2.4 0.4 3.4 1.5 2.4 0.4 3.4 1.5 2.4 0.5 3.4 1.1 116 5 126 165 1.3 0.1 1.6 0.9 01/28/2007 17:40:00 3.3 0.4 4.2 2.6 3.4 0.4 4.6 2.6 3.3 0.4 4.6 2.6 101 7 106 165 1.4 0.1 1.6 0.9 01/28/2007 17:50:00 4.3 0.6 5.3 3 4.2 0.6 5.7 3 4 0.6 5.3 2.6 113 5 124 165 1.4 0.2 1.6 0.9 01/28/2007 18:00:00 3.8 0.5 4.9 2.6 3.8 0.5 4.9 2.3 3.7 0.5 4.9 2.3 99 5 97 165 1.4 0.1 1.6 0.9 01/28/2007 18:10:00 4 0.4 4.9 3 4.4 0.4 5.3 3.4 4.3 0.4 4.9 3.4 93 4 93 165 1.4 0.1 1.6 0.9 01/28/2007 18:20:00 3.7 0.4 4.6 2.6 4 0.4 4.9 2.6 3.7 0.5 4.9 2.3 94 5 97 165 1.4 0.1 1.6 0.9 01/28/2007 18:30:00 3.5 0.5 4.9 2.6 3.7 0.5 4.9 2.6 3.1 0.5 4.2 1.9 90 8 101 165 1.4 0.1 1.6 0.9 01/28/2007 18:40:00 3.3 0.6 4.6 1.9 3.4 0.7 4.9 1.9 3 0.7 4.9 1.5 80 10 82 165 1.4 0.1 1.6 0.9 01/28/2007 18:50:00 3.5 0.4 4.6 2.3 3.6 0.4 4.6 1.9 3.2 0.4 4.2 2.3 93 6 105 165 1.4 0.2 1.6 0.9 01/28/2007 19:00:00 4.2 0.5 5.7 2.6 4.5 0.7 6.1 2.6 3.8 0.7 5.3 1.9 98 4 109 165 1.4 0.2 1.6 0.9 01/28/2007 19:10:00 5.1 0.7 6.8 4.2 5.6 0.7 7.2 4.6 5.1 0.9 7.2 3.8 98 5 100 165 1.4 0.2 1.6 0.9 01/28/2007 19:20:00 5.3 0.7 6.8 3.8 5.9 0.7 7.2 4.6 5.4 0.8 7.2 3.8 102 3 100 165 1.4 0.2 1.6 0.9 01/28/2007 19:30:00 4.1 0.6 6.1 3 4.6 0.6 6.5 3.4 4.1 0.6 6.1 2.6 92 8 84 165 1.5 0.2 1.6 0.9 01/28/2007 19:40:00 5 0.6 6.5 3.4 5.5 0.6 7.2 3.8 5 0.6 6.5 3.4 77 6 81 165 1.5 0.1 1.6 0.9 01/28/2007 19:50:00 6.6 0.9 8.4 4.2 7 0.8 8.8 4.6 6.4 0.9 8.4 4.2 78 7 84 165 1.7 0 1.8 1.6 01/28/2007 20:00:00 7.2 0.8 8.8 4.9 7.6 0.7 9.1 5.7 7.1 0.8 8.8 5.3 94 5 97 165 1.7 0 1.8 1.4 01/28/2007 20:10:00 7.6 0.5 8.8 6.1 7.9 0.5 9.1 6.5 7.2 0.7 9.1 5.3 97 4 97 165 1.8 0 1.8 1.4 01/28/2007 20:20:00 7.7 0.5 8.8 6.1 8 0.5 9.1 6.8 7.4 0.6 8.8 5.3 106 5 104 165 1.8 0 1.8 1.4 01/28/2007 20:30:00 7.3 0.6 8.8 5.7 7.5 0.6 9.1 5.7 6.9 0.7 8.4 5.3 108 5 110 165 1.8 0.1 2.1 1.4 01/28/2007 20:40:00 7.3 0.5 8.4 4.9 7.5 0.5 8.8 5.3 7 0.6 8.4 4.6 111 4 112 165 1.8 0.1 1.8 1.4 01/28/2007 20:50:00 7 0.5 8.8 4.6 7.2 0.5 8.4 4.6 6.8 0.6 8 4.6 96 5 85 165 1.8 0.1 2.1 1.4 01/28/2007 21:00:00 6.5 0.6 7.6 4.2 6.7 0.6 8 4.6 6.2 0.7 7.6 3.8 94 6 99 165 1.8 0 1.8 1.4 01/28/2007 21:10:00 5.9 1 7.2 3 6.2 1 8 3.4 5.9 0.9 7.6 3.8 71 13 81 165 1.8 0 1.8 1.6 01/28/2007 21:20:00 6 1 8.4 3.8 6.2 1 8.8 4.2 6 0.8 8.4 4.2 52 9 44 165 1.8 0 1.8 1.6 01/28/2007 21:30:00 6.1 0.6 7.2 4.6 6.3 0.6 7.6 4.6 6 0.7 8 3.8 50 8 48 165 1.8 0 2.1 1.6 01/28/2007 21:40:00 7 0.9 9.1 4.9 7.1 0.9 9.1 5.3 6.9 0.8 8.8 4.9 45 8 44 165 1.8 0 1.8 1.8 01/28/2007 21:50:00 6.1 0.9 8.4 4.2 6.4 0.9 8.8 4.2 6 0.8 8 3.8 43 9 60 165 1.8 0 2.1 1.8 01/28/2007 22:00:00 7.2 1 9.5 4.6 7.3 1 9.5 4.9 7.2 0.8 9.1 4.9 39 7 38 165 1.9 0 2.1 1.6 01/28/2007 22:10:00 6.3 1 9.1 3.4 6.5 1 8.8 3.8 6.3 0.9 8.4 3.4 41 7 37 165 1.9 0.1 2.3 1.4 01/28/2007 22:20:00 6.4 0.8 8.4 4.2 6.6 0.8 8.4 4.6 6.5 0.8 8.8 4.9 37 6 36 165 2 0 2.3 1.6 01/28/2007 22:30:00 6.1 1.2 9.5 3.8 6.3 1.1 9.5 3.8 6 1.2 9.5 3.8 41 6 44 165 1.9 0 2.1 1.6 01/28/2007 22:40:00 5.1 1.1 7.2 3 5.3 1.1 7.6 2.6 5 1 6.8 2.6 55 9 43 165 1.9 0 2.1 1.6 01/28/2007 22:50:00 6.2 1 8.8 4.2 6.5 1 9.1 4.2 6.1 1 9.5 4.2 70 7 78 165 2 0 2.3 1.6 01/28/2007 23:00:00 7.4 1.3 10.3 4.2 7.7 1.2 10.7 4.9 7.2 1.1 10.3 4.9 77 6 77 165 2.3 0 2.6 1.8 01/28/2007 23:10:00 7.4 0.8 9.5 5.3 7.7 0.8 9.9 5.7 7.1 0.8 9.1 4.9 82 5 79 165 2.4 0.1 2.6 1.8 01/28/2007 23:20:00 7.3 0.8 9.1 4.9 7.7 0.8 9.5 5.7 7.2 0.8 8.8 5.3 85 5 92 165 2.5 0.1 2.8 1.8 01/28/2007 23:30:00 8.3 1.3 11.8 5.7 8.6 1.2 11.8 6.1 8 1.2 11.1 5.7 87 6 91 165 2.5 0.1 2.8 1.8 01/28/2007 23:40:00 9.2 1.2 11.5 5.7 9.4 1.2 11.5 6.1 8.9 1.2 11.1 6.1 82 8 84 165 2.4 0.1 2.8 1.8 01/28/2007 23:50:00 8.2 1.2 11.8 5.3 8.4 1.2 11.8 5.7 7.9 1.1 11.1 5.3 65 11 59 165 2.4 0 2.6 2.1 01/29/2007 00:00:00 9.3 1.3 12.6 5.7 9.5 1.4 13 5.7 9.1 1.3 11.8 6.1 66 8 68 165 2.4 0 2.6 2.1 01/29/2007 00:10:00 10.6 1.3 14.1 7.6 10.7 1.3 14.5 7.6 10.3 1.2 14.1 7.2 68 8 65 165 2.4 0 2.6 2.1 01/29/2007 00:20:00 10.8 1.2 14.1 8 11.1 1.3 14.5 8 10.6 1.2 13.7 7.2 75 7 84 165 2.4 0 2.6 2.3 01/29/2007 00:30:00 11.1 1.4 14.9 7.6 11.3 1.5 15.3 7.6 10.7 1.4 14.5 7.6 80 7 74 165 2.4 0 2.6 2.3 01/29/2007 00:40:00 11.7 1.4 15.3 8.4 11.9 1.4 15.3 8.8 11.4 1.3 14.9 8.4 76 7 79 165 2.4 0 2.6 2.3 01/29/2007 00:50:00 13.3 1.6 16.8 9.5 13.6 1.6 17.2 9.9 13 1.5 16.8 9.1 84 6 88 165 2.4 0 2.6 2.3 01/29/2007 01:00:00 14 1.6 17.6 9.9 14.3 1.7 17.6 10.3 13.5 1.7 16.8 9.5 87 6 89 165 2.4 0 2.8 2.3 01/29/2007 01:10:00 13.1 1.5 16.8 9.9 13.4 1.5 16.8 9.9 12.8 1.4 16.4 9.1 84 5 83 165 2.6 0 2.8 2.3 01/29/2007 01:20:00 13.5 1.7 17.6 9.5 13.8 1.7 17.9 9.9 12.9 1.7 17.6 8.8 90 6 88 165 2.6 0 2.8 2.6 01/29/2007 01:30:00 14.5 1.4 17.9 10.3 14.8 1.5 18.3 9.9 13.7 1.6 17.9 8.8 90 6 98 165 2.6 0 2.8 2.6 01/29/2007 01:40:00 15.6 1.7 20.2 10.7 15.9 1.7 20.6 11.1 14.8 1.7 19.9 9.9 92 6 90 165 2.6 0 2.8 2.6 01/29/2007 01:50:00 15.3 1.3 19.9 11.5 15.5 1.3 19.9 12.2 14.7 1.5 19.1 11.1 92 5 92 165 2.6 0 2.8 2.6 01/29/2007 02:00:00 15.5 1.7 19.5 11.1 15.8 1.7 19.9 10.7 14.9 1.7 18.3 10.3 94 5 94 165 2.7 0 2.8 2.6 01/29/2007 02:10:00 16 1.7 21.4 10.7 16.3 1.7 21.4 10.7 15.2 1.9 21.4 9.9 100 5 97 165 2.6 0 2.8 2.6 01/29/2007 02:20:00 16.7 1.7 20.6 12.2 17 1.7 21 12.6 16 1.9 21 11.1 98 5 104 165 2.6 0 2.8 2.6 01/29/2007 02:30:00 16.1 1.6 20.2 12.2 16.4 1.6 20.6 12.6 15.4 1.8 21.4 11.1 97 7 98 165 2.4 0.1 2.8 1.8 01/29/2007 02:40:00 16.3 1.5 19.5 11.8 16.5 1.5 19.9 11.8 15.6 1.5 19.5 11.8 94 6 94 165 2.3 0 2.6 1.8 01/29/2007 02:50:00 15.2 1.5 19.5 10.7 15.5 1.6 19.9 11.5 14.6 1.6 19.5 11.1 92 6 91 165 2.3 0.1 2.6 1.8 01/29/2007 03:00:00 15.4 1.3 19.1 11.8 15.7 1.3 19.1 11.8 14.9 1.3 18.7 11.5 91 6 87 165 2.4 0.2 2.6 1.8 01/29/2007 03:10:00 15.7 1.2 18.3 11.5 16 1.3 18.7 11.8 14.9 1.4 17.9 11.5 82 6 85 165 2.3 0.1 2.6 1.8 01/29/2007 03:20:00 14.8 1.3 18.3 10.3 15 1.4 18.7 10.7 14.3 1.3 17.6 10.7 78 6 87 165 2.3 0.2 2.8 1.8 01/29/2007 03:30:00 15.5 1.5 18.7 11.5 15.8 1.5 19.1 11.5 15 1.5 18.7 10.3 80 6 83 165 2.5 0.1 2.8 1.8 01/29/2007 03:40:00 15.2 1.5 19.1 11.5 15.5 1.5 19.1 11.5 14.6 1.5 17.9 11.1 84 6 81 165 2.6 0.1 2.8 1.8 01/29/2007 03:50:00 16.1 1.7 21.4 11.5 16.5 1.7 21.8 11.8 15.6 1.7 19.9 11.1 82 6 79 165 2.6 0.1 2.8 1.8 01/29/2007 04:00:00 14.1 1.7 18.3 9.5 14.3 1.8 18.3 9.9 13.7 1.7 17.9 9.1 75 8 83 165 2.6 0 2.8 2.1 01/29/2007 04:10:00 12.9 1.7 17.9 9.1 13.2 1.8 18.3 9.5 12.6 1.7 17.6 8 78 10 72 165 2.7 0 2.8 2.1 01/29/2007 04:20:00 15.8 2.2 20.6 10.7 16.1 2.2 21.4 10.7 15.3 2.4 21 9.9 89 7 84 165 2.5 0.2 2.8 1.8 01/29/2007 04:30:00 13.8 1.7 17.9 9.5 14 1.8 18.7 9.1 13.2 1.6 17.9 8.8 90 8 98 165 2.5 0.1 2.8 1.8 01/29/2007 04:40:00 13.9 1.5 17.9 8.8 14.2 1.5 18.3 9.1 13.5 1.5 17.6 9.9 83 6 79 165 2.5 0.1 2.8 1.8 01/29/2007 04:50:00 16.2 1.7 19.9 11.5 16.5 1.7 20.2 11.5 15.6 1.8 19.5 11.1 85 6 89 165 2.6 0.1 2.8 2.1 01/29/2007 05:00:00 16.8 1.9 21.8 11.5 17.1 2 22.1 12.2 16.3 1.9 21.4 12.2 82 6 88 165 2.6 0 2.8 1.8 01/29/2007 05:10:00 17.5 1.9 21.8 12.2 17.8 1.9 22.1 13 16.8 1.9 21.8 12.6 80 7 89 165 2.7 0 2.8 2.6 01/29/2007 05:20:00 18.8 1.7 23.7 13.7 19.1 1.7 23.7 13.7 17.8 1.7 22.1 13 82 5 81 165 2.7 0 3 2.6 01/29/2007 05:30:00 16.7 1.9 21.8 11.5 17 2 22.1 11.8 16.1 1.9 21 11.8 85 6 84 165 2.7 0 3 2.6 01/29/2007 05:40:00 14.2 1.9 18.7 9.5 14.5 1.9 19.1 9.5 13.5 2 17.9 8.8 94 8 95 165 2.7 0 2.8 2.6 01/29/2007 05:50:00 13.7 2.4 21 8.4 14 2.4 21.8 7.6 13.2 2.3 20.6 6.8 102 9 102 165 2.9 0 3 2.6 01/29/2007 06:00:00 12.5 2.3 21 8 12.5 2.3 21 7.2 12.3 2.4 21 7.6 122 14 133 165 2.9 0 3.3 2.8 01/29/2007 06:10:00 14.2 2 19.9 9.1 14.2 2 19.9 9.1 13.7 1.9 19.1 9.5 125 10 105 165 3 0 3.3 2.8 01/29/2007 06:20:00 14.7 1.7 20.2 9.1 14.8 1.7 20.2 9.9 14.2 1.8 19.5 9.5 125 8 121 165 3.1 0 3.3 2.8 01/29/2007 06:30:00 14.7 1.9 22.1 9.9 14.8 1.9 21.8 10.3 14.2 2 21 9.5 126 7 121 165 3.2 0 3.5 3 01/29/2007 06:40:00 16.4 2.2 21.4 11.5 16.4 2.2 21.4 11.5 16 2.4 21.8 10.3 128 9 117 165 3.3 0 3.5 3.3 01/29/2007 06:50:00 16.6 2 24 11.5 16.7 2 24.4 11.8 16.3 2.1 25.2 11.5 129 8 123 165 3.4 0 3.5 3.3 01/29/2007 07:00:00 17.4 1.8 23.3 13.3 17.4 1.8 22.9 13 17.2 2 23.7 12.2 133 7 134 165 3.5 0.1 3.8 2.6 01/29/2007 07:10:00 19.1 1.8 25.2 13.7 19 1.8 25.2 13.7 18.8 1.8 23.7 13.7 135 8 135 165 3.5 0.1 3.8 3 01/29/2007 07:20:00 18.7 1.7 23.3 13.7 18.6 1.7 23.3 13.7 18.2 2.2 24.4 11.5 135 9 143 165 3.5 0.1 3.8 3 01/29/2007 07:30:00 17.9 1.8 25.2 13 17.8 1.8 25.2 13.3 17.7 1.8 24 13.7 137 8 135 165 3.6 0.1 3.8 2.8 01/29/2007 07:40:00 17.1 2.2 21.8 8.4 17 2.2 21.4 8.4 16.8 2.1 21.8 10.3 138 8 140 165 3.6 0.1 3.8 3 01/29/2007 07:50:00 15.5 1.7 20.6 9.5 15.4 1.7 20.2 10.3 15.3 1.7 19.1 10.3 142 9 144 165 3.6 0.1 3.8 3 01/29/2007 08:00:00 14.3 2 19.1 10.3 14.2 1.9 19.1 10.3 14 1.9 18.7 9.5 138 10 128 165 3.7 0 4 3.3 01/29/2007 08:10:00 11.8 1.3 15.6 9.1 11.8 1.3 16.1 8.8 11.7 1.3 15.6 8.8 144 9 144 165 3.7 0 4 3.3 01/29/2007 08:20:00 12.7 2.3 18.3 8.8 12.5 2.3 18.3 8.8 12.6 2.2 17.9 8.8 145 6 140 165 3.7 0.1 4 3 01/29/2007 08:30:00 10.1 1 13 7.6 10 1 13 7.6 9.8 1 13 6.8 143 6 137 165 3.6 0.1 3.8 3 01/29/2007 08:40:00 9.7 0.8 12.6 7.6 9.6 0.8 12.2 7.6 9.6 0.8 11.8 7.6 144 6 135 165 3.8 0 4.3 3.3 01/29/2007 08:50:00 9.2 1 12.2 7.2 9.1 1 12.2 6.8 9 1 11.5 6.8 146 6 139 165 3.8 0.1 4.3 3.3 01/29/2007 09:00:00 8.9 1.3 12.2 6.1 8.8 1.2 12.2 6.1 8.9 1.3 12.2 6.1 147 6 133 165 3.9 0 4.3 3.5 01/29/2007 09:10:00 11.2 1.7 16.1 7.6 11 1.7 16.1 7.6 10.8 1.6 15.3 8 140 9 134 165 4 0 4.3 3.5 01/29/2007 09:20:00 12.5 1.3 17.2 8.8 12.4 1.3 16.8 8.8 12.3 1.3 16.1 8.8 140 8 142 165 4.1 0.1 4.5 3.5 01/29/2007 09:30:00 11.2 1.5 15.3 7.6 11.2 1.5 15.3 8 11 1.5 15.6 7.6 142 9 116 165 4 0.1 4.3 3.5 01/29/2007 09:40:00 11.9 1.1 15.3 9.1 11.8 1.1 14.5 8.8 11.6 1.1 14.9 8 143 7 129 165 4 0.1 4.3 3.5 01/29/2007 09:50:00 10.6 1.1 13.7 8 10.5 1.1 13.3 8 10.3 1 12.6 7.6 142 7 136 165 4 0.1 4.3 3.3 01/29/2007 10:00:00 10.9 1.3 14.5 8 10.8 1.3 14.5 8 10.8 1.3 14.1 7.6 143 6 135 165 4.1 0.1 4.3 3.5 01/29/2007 10:10:00 11.3 1.6 15.6 8.4 11.2 1.6 15.6 8.4 11.2 1.8 14.9 6.5 140 8 142 165 4.1 0.1 4.5 3.5 01/29/2007 10:20:00 11.8 1.2 15.6 9.1 11.7 1.2 14.9 9.1 11.3 1.2 14.5 8 137 10 126 165 4.1 0.1 4.5 3.5 01/29/2007 10:30:00 11.5 1.2 14.9 8.8 11.4 1.2 14.9 8.8 11.2 1.3 14.5 8 143 8 143 165 4.1 0.1 4.3 3.5 01/29/2007 10:40:00 11.8 1.2 14.9 8.4 11.7 1.2 14.9 8.4 11.6 1.2 14.5 8.4 142 6 140 165 4 0 4.3 3.5 01/29/2007 10:50:00 12.2 1 15.3 9.5 12.1 1 14.9 9.5 11.9 1.1 16.1 9.1 142 6 142 165 4 0 4.3 3.8 01/29/2007 11:00:00 10.8 1 13 8.8 10.7 1 13 8.4 10.6 1 12.6 7.6 143 6 146 165 4 0 4.3 3.8 01/29/2007 11:10:00 11.1 1 14.5 9.1 11 1 14.1 8.8 11 1 14.1 8.8 144 5 142 165 4 0.1 4.3 3.3 01/29/2007 11:20:00 9.4 1 11.5 6.5 9.3 1 11.5 6.5 9.3 0.9 12.2 6.8 145 6 143 165 4 0 4.3 3.8 01/29/2007 11:30:00 8.5 1 10.7 6.5 8.4 0.9 10.7 6.5 8.3 0.9 10.3 6.5 143 6 135 165 4 0 4.3 3.8 01/29/2007 11:40:00 8.2 1 10.7 5.3 8.1 1 10.7 4.9 8 1 10.3 4.9 141 7 139 165 4 0 4.3 3.5 01/29/2007 11:50:00 9 0.8 11.1 6.5 8.9 0.8 11.5 6.1 8.8 0.7 10.7 5.3 142 6 137 165 4 0 4.3 3.3 01/29/2007 12:00:00 10 1.2 13 7.2 9.9 1.2 12.6 7.2 9.9 1.2 13.3 6.8 142 6 140 165 4 0 4.3 3.3 01/29/2007 12:10:00 11.4 1.2 14.9 8.8 11.3 1.2 14.5 8.8 11.1 1.2 13.7 8.4 142 6 154 165 4 0.1 4.3 3.3 01/29/2007 12:20:00 11.4 1 13.7 8.8 11.3 1 13.7 8 11.2 1.1 13.7 7.6 141 6 139 165 4 0.1 4.3 3.3 01/29/2007 12:30:00 11.2 1.1 13.3 8.4 11.1 1.1 13.3 8.4 11 1.1 13.3 8 141 5 140 165 4 0.1 4.3 3.3 01/29/2007 12:40:00 11.7 0.8 14.5 8.8 11.6 0.8 14.5 8.8 11.5 0.9 14.1 9.5 142 6 143 165 4 0 4.3 3.3 01/29/2007 12:50:00 12.4 1.1 15.3 9.5 12.3 1 14.9 9.5 12.2 1.2 14.9 8.8 141 6 139 165 4 0 4.3 3.3 01/29/2007 13:00:00 12.8 0.9 14.9 10.7 12.7 0.9 14.9 10.7 12.6 1 14.5 9.9 142 6 135 165 4 0.1 4.3 3.3 01/29/2007 13:10:00 12.6 1.1 15.3 9.9 12.5 1.1 14.9 9.5 12.4 1 14.9 9.1 143 5 136 165 4 0 4.3 3.5 01/29/2007 13:20:00 12.2 0.9 14.1 9.1 12.1 0.9 14.5 8.8 11.9 0.9 14.1 8.8 142 7 145 165 3.9 0 4.3 3.3 01/29/2007 13:30:00 12.6 1 14.9 9.9 12.5 1 14.9 9.9 12.6 1 14.5 9.1 144 6 143 165 4 0.1 4.3 3.3 01/29/2007 13:40:00 12.6 0.9 14.9 9.9 12.5 0.9 14.5 9.5 12.5 1 16.1 9.5 142 5 141 165 4 0 4.3 3.5 01/29/2007 13:50:00 12.1 1 14.5 9.5 12 1 14.5 8.8 11.9 1.1 14.1 9.1 143 5 139 165 4 0.1 4.3 3.3 01/29/2007 14:00:00 11.5 1.3 15.3 8.8 11.4 1.3 14.9 8.4 11.4 1.3 15.3 8 141 7 142 165 4 0 4.3 3.5 01/29/2007 14:10:00 11.8 1.1 14.5 9.1 11.7 1 14.1 9.1 11.7 1 14.5 9.1 142 6 126 165 4 0.1 4.3 3.3 01/29/2007 14:20:00 11.3 1 13.7 8.8 11.2 1 13.7 8.4 11.2 0.9 14.1 9.1 142 7 137 165 3.9 0.1 4.3 3.3 01/29/2007 14:30:00 12.2 1 14.5 9.9 12.1 1 14.5 8 11.9 1 14.5 8.4 140 10 145 165 3.9 0.1 4.3 3.3 01/29/2007 14:40:00 11.6 1 13.7 8.8 11.4 1 13.7 8 11.3 1 13.7 8.8 143 6 134 165 3.9 0 4.3 3.8 01/29/2007 14:50:00 11.8 0.9 13.7 9.5 11.7 0.9 13.7 9.5 11.5 1 13.7 9.1 144 6 138 165 3.8 0 4.3 3.8 01/29/2007 15:00:00 10.9 1 13.3 7.6 10.8 1 13.3 8.4 10.7 0.9 13.7 8.8 146 5 147 165 3.8 0 4 3.5 01/29/2007 15:10:00 11.1 1.1 14.1 8.8 10.9 1 14.1 8.8 10.7 0.9 13 8.8 145 5 148 165 3.8 0 4.3 3.5 01/29/2007 15:20:00 11.1 1.1 13.7 8.4 11 1.1 13.3 8.4 10.8 1.2 13.7 7.6 144 5 145 165 3.8 0 4.3 3.5 01/29/2007 15:30:00 12.5 1.5 16.8 8.8 12.4 1.5 16.4 8.8 12.1 1.6 15.6 7.6 142 8 151 165 3.8 0 4.3 3.3 01/29/2007 15:40:00 12.9 1.3 16.8 10.3 12.8 1.2 16.4 10.3 12.8 1.2 15.6 9.5 147 5 144 165 3.8 0 4.3 3.5 01/29/2007 15:50:00 13.4 1 15.6 10.3 13.2 1 15.3 10.3 13.1 1 14.9 9.9 148 5 147 165 3.8 0 4 3.5 01/29/2007 16:00:00 13.3 1 16.1 10.3 13.1 1 16.1 10.7 13.1 1 15.3 10.7 148 5 145 165 3.8 0 4 3.5 01/29/2007 16:10:00 14.3 1 16.4 11.1 14.1 1 16.1 11.1 14 1 16.8 10.7 148 4 150 165 3.7 0 4 3.3 01/29/2007 16:20:00 14.1 0.8 16.1 12.2 13.9 0.8 16.1 11.8 13.8 0.8 16.1 11.8 148 3 143 165 3.6 0.1 3.8 3.3 01/29/2007 16:30:00 14.3 1 16.8 11.8 14.1 1 16.8 11.8 14 1 16.8 11.5 149 6 149 165 3.7 0.1 3.8 3.3 01/29/2007 16:40:00 13.9 0.8 16.8 11.8 13.6 0.8 16.4 11.1 13.5 0.8 16.4 11.1 148 5 147 165 3.6 0 3.8 3.3 01/29/2007 16:50:00 14.8 0.8 16.8 13 14.6 0.8 16.8 12.6 14.4 0.9 17.2 10.7 148 4 143 165 3.7 0 3.8 3.3 01/29/2007 17:00:00 15 0.8 17.2 13 14.8 0.8 17.2 13 14.7 0.7 16.8 12.6 149 4 142 165 3.7 0.1 3.8 3.3 01/29/2007 17:10:00 14.5 0.8 16.8 12.2 14.3 0.8 16.4 12.2 14.1 0.8 16.1 12.2 149 4 151 165 3.6 0.1 3.8 3 01/29/2007 17:20:00 14.7 0.7 16.4 12.6 14.4 0.7 16.1 12.2 14.3 0.9 16.4 11.8 149 3 145 165 3.6 0.1 3.8 3.3 01/29/2007 17:30:00 15 1 17.2 12.6 14.8 1 16.8 12.2 14.7 1.2 17.9 11.5 149 4 148 165 3.7 0 4.3 3.3 01/29/2007 17:40:00 14.2 0.8 16.4 11.8 14 0.8 16.1 11.5 13.8 0.8 16.4 11.5 150 4 149 165 3.6 0.1 3.8 3.3 01/29/2007 17:50:00 14.3 1 17.6 12.2 14.1 1 16.8 11.8 14.1 1 17.6 11.5 150 3 152 165 3.6 0 4 3.3 01/29/2007 18:00:00 15.3 1 18.3 13 15.1 1 17.9 12.6 14.8 1 17.6 12.2 149 4 152 165 3.6 0.1 3.8 3.3 01/29/2007 18:10:00 15.5 0.8 17.6 13.3 15.3 0.8 17.2 13.3 15.1 0.8 17.6 12.6 150 3 154 165 3.6 0.1 3.8 3 01/29/2007 18:20:00 15.9 0.9 18.7 13.7 15.7 0.9 18.3 13.3 15.4 0.9 17.9 12.2 150 4 156 165 3.6 0.1 3.8 3 01/29/2007 18:30:00 15.8 0.8 17.9 13.3 15.6 0.8 17.9 13.3 15.4 0.8 17.6 13.3 151 4 152 165 3.6 0 3.8 3.5 01/29/2007 18:40:00 15.4 1.2 19.5 12.6 15.2 1.1 19.5 12.6 15.1 1.3 19.5 12.6 149 7 150 165 3.6 0 3.8 3.5 01/29/2007 18:50:00 15.8 1.2 18.3 12.6 15.5 1.2 17.9 12.2 15.5 1.2 17.9 12.2 150 4 153 165 3.6 0 3.8 3.3 01/29/2007 19:00:00 16.3 0.8 18.3 14.1 16 0.8 18.3 13.7 16.1 1 18.7 12.2 152 5 154 165 3.6 0 3.8 3.5 01/29/2007 19:10:00 15.5 1.1 18.3 12.6 15.3 1.1 17.9 12.6 15.6 1.2 18.3 13.3 153 5 154 165 3.7 0 3.8 3.3 01/29/2007 19:20:00 13.6 1.1 15.6 10.3 13.2 1.1 15.6 9.5 13.7 1.1 15.6 10.7 151 15 155 165 3.6 0 3.8 3.5 01/29/2007 19:30:00 10.6 1 13 7.2 10.2 0.9 12.6 7.2 10.6 1 13 8 158 21 164 165 3.6 0 3.8 3.5 01/29/2007 19:40:00 10.2 0.5 11.8 8.8 9.7 0.5 11.5 8 10 0.5 11.8 8.4 170 11 116 165 3.7 0 4 3.3 01/29/2007 19:50:00 12.4 2.1 17.2 8 11.9 2 16.4 8 12.2 2.2 16.4 7.6 171 15 184 165 4 0.1 4.3 3.5 01/29/2007 20:00:00 13.5 1.1 15.6 10.3 13.1 1.1 15.3 9.9 13.6 1.2 16.4 9.9 160 22 174 165 3.9 0 4.3 3.5 01/29/2007 20:10:00 13.3 0.8 15.6 11.5 13 0.8 15.3 11.5 13.3 0.9 15.3 10.7 158 23 157 165 3.8 0 4.3 3.3 01/29/2007 20:20:00 11.8 1.1 14.1 8.4 11.5 1.1 13.7 8.4 11.7 1.1 14.1 9.1 159 22 165 165 3.8 0.1 4.3 3 01/29/2007 20:30:00 9.8 0.8 11.8 7.2 9.5 0.8 11.1 6.8 9.6 0.9 11.5 6.8 162 18 165 165 3.8 0 4.3 3.3 01/29/2007 20:40:00 5.4 1 8.4 3.8 5.1 1 8 3.4 5.4 0.9 8 3.8 171 10 169 165 3.8 0 4 3.3 01/29/2007 20:50:00 6.3 1.5 9.5 3.4 6.1 1.5 8.8 3.4 6.4 1.5 8.8 3.4 164 12 155 165 3.8 0 4 3.3 01/29/2007 21:00:00 7.7 1.2 10.7 4.9 7.5 1.1 10.3 4.6 7.9 1.1 10.3 4.9 162 12 165 165 3.8 0 4.3 3.3 01/29/2007 21:10:00 8.9 1 11.8 6.8 8.6 1 11.5 6.8 9 1 12.2 6.8 160 15 167 165 3.7 0 4 3.3 01/29/2007 21:20:00 10.5 1.2 13 8 10 1.1 12.6 7.6 10.2 1.1 13 8 163 17 139 165 3.6 0.1 3.8 3 01/29/2007 21:30:00 10.2 0.8 12.6 8.4 9.7 0.8 12.2 8 10.1 0.9 12.6 8 171 15 171 165 3.8 0 4 3 01/29/2007 21:40:00 10 0.9 12.2 8 9.6 0.8 11.5 7.6 9.8 0.9 12.2 8 171 9 180 165 3.8 0 4 3.3 01/29/2007 21:50:00 10.6 0.8 11.8 8.8 10.1 0.7 11.5 8 10.6 0.8 12.2 8.4 168 12 173 165 3.6 0.1 4 3.3 01/29/2007 22:00:00 9.8 0.5 10.7 8.4 9.3 0.4 10.3 8 9.7 0.5 11.1 8 172 7 172 165 3.8 0 4 3.3 01/29/2007 22:10:00 8.7 0.6 9.9 7.2 8.3 0.5 9.5 6.5 8.5 0.6 9.9 6.8 174 6 167 165 3.7 0 3.8 3.3 01/29/2007 22:20:00 7.1 0.7 8.4 5.3 6.7 0.7 8 5.3 7 0.8 8.4 5.3 176 6 175 165 3.7 0 4 3.3 01/29/2007 22:30:00 5.8 0.6 6.8 4.2 5.5 0.6 6.5 3.8 5.8 0.7 7.2 4.2 170 8 180 165 3.7 0.1 4 3.3 01/29/2007 22:40:00 4.8 0.4 6.1 3.8 4.5 0.4 5.7 3.8 4.6 0.4 5.7 3.8 165 9 165 165 3.6 0 4 3.3 01/29/2007 22:50:00 5.2 0.6 6.8 4.2 5.1 0.6 6.8 3.8 5.2 0.7 6.8 4.2 164 18 138 165 3.8 0 4.3 3.5 01/29/2007 23:00:00 6.5 0.9 9.1 4.9 6.3 0.8 8.8 4.9 6.4 0.8 8.8 4.6 157 11 116 165 4 0.1 4.5 3.5 01/29/2007 23:10:00 7.3 0.9 9.5 4.9 7 0.8 9.1 4.9 7.3 0.7 9.5 5.3 163 12 170 165 4 0.1 4.3 3.5 01/29/2007 23:20:00 8.1 0.9 10.3 6.1 7.7 0.9 9.9 6.1 8 0.9 9.9 6.1 163 12 165 165 4 0.1 4.3 3.5 01/29/2007 23:30:00 7.9 0.8 9.9 5.7 7.6 0.7 9.5 5.7 7.8 0.6 9.5 6.5 160 17 156 165 3.9 0 4.3 3.5 01/29/2007 23:40:00 5.8 0.9 8 4.2 5.7 0.8 8 3.8 5.9 0.8 8 4.6 159 12 153 165 3.9 0 4.3 3.3 01/29/2007 23:50:00 4.5 0.6 5.7 3 4.4 0.6 5.7 2.6 4.6 0.6 6.1 3.4 151 11 159 165 3.7 0.1 4 3.3 01/30/2007 00:00:00 5.1 0.6 6.8 3.4 5 0.6 6.8 3.4 5.2 0.6 7.2 4.2 150 11 157 165 3.7 0.1 4.3 3.3 01/30/2007 00:10:00 4.7 0.4 5.7 3.8 4.8 0.4 6.1 3.8 4.9 0.4 6.1 4.2 142 7 147 165 3.6 0.1 3.8 3 01/30/2007 00:20:00 4 0.2 4.6 3.4 4.1 0.3 4.9 3 4.3 0.3 4.9 3.4 142 4 147 165 3.6 0.1 3.8 3.3 01/30/2007 00:30:00 3.7 0.3 4.2 3 3.9 0.2 4.6 3.4 4 0.2 4.6 3.4 140 3 143 165 3.6 0.1 3.8 3.3 01/30/2007 00:40:00 3.3 0.3 3.8 2.6 3.4 0.3 4.2 2.6 3.5 0.3 4.2 2.6 137 3 136 165 3.5 0.1 3.8 3 01/30/2007 00:50:00 3.5 0.3 4.2 2.6 3.7 0.3 4.6 2.6 3.9 0.3 4.6 3 133 5 135 165 3.5 0.1 3.8 3 01/30/2007 01:00:00 3.9 0.4 4.6 3 4.1 0.4 4.9 3 4.1 0.4 4.9 3 130 5 134 165 3.5 0.1 3.8 3 01/30/2007 01:10:00 4.4 0.6 5.7 3 4.7 0.6 6.1 3 4.6 0.7 6.1 3 127 5 124 165 3.5 0 3.5 3 01/30/2007 01:20:00 4.6 0.5 6.1 3.4 4.9 0.5 6.1 3.4 4.9 0.6 6.5 3.4 130 7 135 165 3.5 0.1 3.8 3 01/30/2007 01:30:00 4.9 0.8 6.8 3.4 5.1 0.8 6.8 3.4 5.1 0.8 6.8 3 124 6 124 165 3.5 0 3.5 3 01/30/2007 01:40:00 6.8 0.7 8.8 4.9 6.9 0.6 8.4 5.3 6.7 0.6 8.4 5.3 128 5 136 165 3.5 0 3.5 3 01/30/2007 01:50:00 6.9 0.7 8.4 4.2 6.8 0.6 8.4 4.6 6.5 0.9 8.4 3.8 136 6 129 165 3.5 0 3.8 3 01/30/2007 02:00:00 7.2 0.8 9.5 4.6 7.2 0.8 9.5 4.9 7 0.8 9.1 4.2 139 6 141 165 3.5 0.1 3.8 3 01/30/2007 02:10:00 7.6 0.8 9.5 6.1 7.6 0.8 9.5 5.7 7.3 0.8 9.5 4.9 138 6 133 165 3.5 0.1 3.8 3 01/30/2007 02:20:00 7 0.9 9.1 4.2 7 0.8 9.1 4.2 6.7 0.9 9.1 3.8 137 7 136 165 3.5 0.1 3.8 3 01/30/2007 02:30:00 7.1 0.8 9.1 4.9 7 0.7 9.1 4.9 7 0.7 8.8 4.6 144 7 137 165 3.5 0.1 3.8 3 01/30/2007 02:40:00 7.1 0.6 9.1 5.7 7 0.6 9.1 5.7 6.8 0.6 8.8 4.9 142 5 151 165 3.5 0.1 3.5 3 01/30/2007 02:50:00 7.6 0.8 9.5 5.3 7.5 0.7 9.9 4.9 7.3 0.7 9.5 5.3 140 7 139 165 3.5 0.1 3.8 3 01/30/2007 03:00:00 7.8 0.7 9.9 6.1 7.7 0.7 9.5 6.1 7.5 0.7 9.9 5.7 138 7 150 165 3.5 0.1 3.5 3 01/30/2007 03:10:00 7.4 0.9 9.1 4.6 7.3 0.8 9.1 4.9 7.1 0.8 8.8 4.6 138 6 143 165 3.5 0.1 3.8 3 01/30/2007 03:20:00 7.6 0.8 10.3 6.1 7.6 0.7 10.3 5.7 7.5 0.7 9.1 6.1 136 7 137 165 3.5 0.1 3.8 3 01/30/2007 03:30:00 7 0.7 8.8 4.9 7 0.7 8.8 4.9 6.9 0.7 8.8 4.6 132 7 143 165 3.5 0.1 3.8 3 01/30/2007 03:40:00 7.2 0.9 9.9 4.9 7.2 0.8 9.5 5.3 7.1 0.8 9.5 4.9 124 7 111 165 3.5 0.1 3.8 3.3 01/30/2007 03:50:00 6 0.6 7.2 4.2 6.3 0.6 7.6 4.6 6.2 0.5 7.6 4.9 125 5 135 165 3.6 0.1 3.8 3.3 01/30/2007 04:00:00 7.1 1 9.1 4.6 7 0.8 8.8 4.6 7.1 0.8 8.8 4.9 144 7 143 165 3.5 0.1 3.8 3 01/30/2007 04:10:00 7.1 0.7 8.4 5.3 6.9 0.7 8.4 4.9 7 0.6 9.1 5.3 143 6 141 165 3.5 0.1 3.5 2.8 01/30/2007 04:20:00 8.6 1.5 12.2 6.1 8.6 1.5 11.8 6.1 8.4 1.5 11.8 5.7 139 6 141 165 3.3 0 3.5 3 01/30/2007 04:30:00 8.5 0.6 10.3 6.5 8.4 0.6 10.3 6.8 8.2 0.8 10.7 5.7 141 6 137 165 3.2 0 3.5 3 01/30/2007 04:40:00 7.4 0.7 9.1 5.7 7.4 0.7 9.1 5.7 7.3 0.7 8.8 5.3 142 6 150 165 3.2 0 3.3 3 01/30/2007 04:50:00 7.3 0.7 9.1 5.3 7.3 0.7 9.5 5.3 7.2 0.6 8.4 5.7 130 7 136 165 3.1 0 3.3 3 01/30/2007 05:00:00 7.6 0.7 9.1 5.3 7.6 0.7 9.5 5.3 7.5 0.7 9.5 5.3 122 7 122 165 3 0.1 3.3 2.8 01/30/2007 05:10:00 7.5 0.9 9.9 4.9 7.6 0.9 10.3 4.6 7.2 0.8 10.3 4.6 113 9 104 165 3 0 3.3 2.8 01/30/2007 05:20:00 6.8 0.9 9.1 4.2 6.9 0.9 9.1 3.8 6.6 0.9 8.8 4.6 106 9 111 165 3 0 3.3 2.8 01/30/2007 05:30:00 6.5 0.9 9.1 3.8 6.8 0.9 9.1 4.2 6.7 0.8 9.1 4.9 91 9 87 165 3.1 0 3.3 2.6 01/30/2007 05:40:00 6.9 0.7 8.4 5.3 7.3 0.6 9.1 6.1 6.9 0.6 8.4 5.3 82 6 94 165 3.1 0.1 3.5 2.8 01/30/2007 05:50:00 6.1 1.2 8.8 2.6 6.4 1.2 8.8 3 6 1.2 8.4 2.6 74 11 80 165 2.9 0 3.3 2.1 01/30/2007 06:00:00 5.6 1 8 3.4 5.9 1 8.4 3.8 5.4 1 8.4 3.8 72 12 81 165 2.7 0 3 2.6 01/30/2007 06:10:00 5 0.8 7.6 3.4 5.4 0.8 8 3.4 5 0.8 8 3 72 10 84 165 2.7 0 2.8 2.6 01/30/2007 06:20:00 5.7 0.7 7.2 3.4 6.1 0.7 7.6 3.8 5.8 0.7 8 3.8 76 6 78 165 2.6 0 2.8 2.3 01/30/2007 06:30:00 6.3 0.8 8 4.2 6.6 0.7 8.4 4.6 6.4 0.7 8.8 4.6 85 9 74 165 2.7 0.2 3.3 2.3 01/30/2007 06:40:00 7.3 0.9 10.3 5.3 7.6 0.9 10.3 5.7 6.9 0.8 9.5 4.9 83 9 96 165 3 0.2 3.5 1.8 01/30/2007 06:50:00 8.5 0.6 9.9 6.5 8.7 0.7 10.3 6.1 8.1 0.8 9.9 5.3 93 6 87 165 3.3 0.2 3.8 2.6 01/30/2007 07:00:00 9 0.8 11.1 6.1 9.3 0.9 11.5 6.5 8.7 1 11.1 6.1 88 6 91 165 3.3 0 3.5 3 01/30/2007 07:10:00 8.5 1.2 11.1 5.3 8.8 1.2 11.5 5.7 7.7 1.1 10.3 4.6 81 9 90 165 3 0.2 3.5 2.6 01/30/2007 07:20:00 10 0.7 11.8 8 10.4 0.7 12.2 8 9.3 0.9 11.5 6.8 92 5 91 165 3.6 0.1 4 3 01/30/2007 07:30:00 12.2 1 14.1 8 12.5 1 14.1 8.4 11.2 1.1 13.3 7.2 93 4 97 165 4.1 0.2 4.5 3.5 01/30/2007 07:40:00 12.6 1 14.9 9.5 13 1.1 15.6 9.5 12.1 1.1 14.5 8.4 90 4 92 165 3.8 0.4 4.5 2.8 01/30/2007 07:50:00 11.4 1.6 14.9 7.2 11.7 1.7 15.3 7.2 10.9 1.5 14.5 7.2 78 11 87 165 3.2 0.2 3.5 2.1 01/30/2007 08:00:00 11.5 1.8 17.2 7.2 11.7 1.9 17.6 6.8 10.8 1.8 15.6 5.7 71 10 78 165 2.9 0.1 3.3 2.6 01/30/2007 08:10:00 11.2 1.8 15.3 6.1 11.4 1.9 15.6 6.5 10.4 1.6 14.5 6.1 69 11 84 165 3 0.1 3.5 2.6 01/30/2007 08:20:00 12.8 1.7 16.1 7.2 13.1 1.7 16.4 8 11.9 1.7 15.6 7.2 72 9 77 165 3 0.3 3.5 2.6 01/30/2007 08:30:00 14.4 1.2 16.8 9.9 14.8 1.3 17.2 9.9 13.7 1.6 17.6 8.4 77 8 84 165 3.6 0.3 4.5 2.8 01/30/2007 08:40:00 14 1.5 17.9 9.5 14.3 1.6 18.3 9.9 13.1 1.9 16.8 7.6 73 11 61 165 3.5 0.5 4.8 2.8 01/30/2007 08:50:00 13.9 1.9 18.7 8.4 14.1 2 19.1 8.8 12.8 2 17.6 7.6 68 9 70 165 3.2 0.3 3.8 2.6 01/30/2007 09:00:00 11.7 2.4 17.6 7.2 11.8 2.5 17.9 6.8 10.9 2.2 17.2 6.8 67 10 74 165 3.2 0.2 3.5 2.6 01/30/2007 09:10:00 8.7 1.2 11.8 5.3 8.8 1.3 11.8 6.1 8.2 1.2 11.5 4.9 67 9 69 165 2.7 0 3 2.6 01/30/2007 09:20:00 9.6 1 12.6 7.2 9.8 1 12.6 7.6 9.3 1 12.2 6.5 80 8 80 165 2.7 0 2.8 2.6 01/30/2007 09:30:00 11.4 1.1 13.3 8 11.6 1.2 13.7 8.4 11 1.2 13.3 8 90 5 87 165 2.7 0 2.8 2.6 01/30/2007 09:40:00 11.3 1 13.7 9.1 11.6 1 14.1 9.1 10.8 1.2 14.1 8.4 94 5 98 165 2.9 0 3 2.6 01/30/2007 09:50:00 11.5 1.2 13.7 7.2 11.8 1.2 14.1 7.2 11 1.3 13.3 6.8 98 5 97 165 2.9 0 3 2.8 01/30/2007 10:00:00 11.2 1.2 14.5 8 11.5 1.2 14.5 8.4 10.7 1.3 14.1 7.2 97 6 89 165 2.9 0 3 2.3 01/30/2007 10:10:00 11.7 1.1 14.1 8 12 1.2 14.9 8 11.3 1.3 14.1 7.2 102 5 102 165 2.9 0.1 3 2.3 01/30/2007 10:20:00 11.1 1.1 13.7 7.6 11.3 1.1 14.1 8 10.6 1.2 13.7 7.2 101 6 113 165 3 0.1 3.3 2.3 01/30/2007 10:30:00 10.8 0.9 14.1 8 11 0.9 14.5 8.4 10.4 1 13 7.2 101 6 108 165 3 0.1 3.3 2.3 01/30/2007 10:40:00 11.6 1.2 14.9 8.4 11.8 1.2 14.9 8.4 11 1.4 14.5 7.6 105 6 102 165 3.1 0 3.3 2.8 01/30/2007 10:50:00 11.6 1.3 14.9 8.4 11.9 1.3 15.3 8.8 11.3 1.3 15.6 7.6 105 8 105 165 3.2 0 3.3 2.8 01/30/2007 11:00:00 12.7 1.5 17.2 9.1 12.9 1.5 17.6 9.1 12.2 1.7 16.8 7.2 111 7 112 165 3.2 0 3.3 2.8 01/30/2007 11:10:00 12.1 1.5 15.6 8 12.3 1.5 16.1 8 11.7 1.7 16.1 7.6 116 6 111 165 3.2 0 3.5 2.8 01/30/2007 11:20:00 13.1 1.1 16.1 9.9 13.2 1.1 16.1 9.9 12.8 1.2 16.1 9.1 121 7 119 165 3.2 0 3.5 3 01/30/2007 11:30:00 13 1.2 16.1 7.6 13.1 1.2 16.8 9.1 12.6 1.2 16.1 9.1 124 7 119 165 3.2 0 3.5 3 01/30/2007 11:40:00 13.8 1.9 19.9 9.1 13.9 2 19.9 9.5 13.3 2 18.3 9.5 120 7 99 165 3.2 0 3.5 3 01/30/2007 11:50:00 14.2 1.7 18.3 8.4 14.4 1.7 18.3 9.1 13.8 1.7 17.6 8.8 119 7 124 165 3.2 0 3.5 3 01/30/2007 12:00:00 14.4 1.7 19.1 10.7 14.5 1.7 19.1 10.7 14.1 1.9 19.1 8.4 127 7 128 165 3.2 0 3.5 3 01/30/2007 12:10:00 14.9 1.5 17.6 9.1 14.9 1.5 17.9 8.8 14.5 1.6 19.9 10.7 132 7 119 165 3.2 0 3.5 2.8 01/30/2007 12:20:00 14.6 1.3 17.9 10.3 14.6 1.3 17.9 10.3 14.2 1.3 17.9 10.7 134 7 138 165 3.2 0 3.5 2.8 01/30/2007 12:30:00 16.4 1.8 21.8 13 16.5 1.8 21.8 13 16 1.9 20.6 11.5 128 6 122 165 3.2 0 3.5 2.6 01/30/2007 12:40:00 17.5 1.5 21 13.3 17.4 1.5 20.6 13 17.2 1.7 21 12.2 135 7 141 165 3 0.1 3.3 2.6 01/30/2007 12:50:00 17.9 1.6 22.6 12.6 17.8 1.6 22.1 11.8 17.3 1.7 21.4 12.2 138 7 149 165 3 0.1 3.3 2.3 01/30/2007 13:00:00 16.8 1.2 20.2 13 16.8 1.2 21 13 16.3 1.3 21 13 135 6 128 165 3 0.1 3.3 2.6 01/30/2007 13:10:00 17 1.5 20.6 12.2 17 1.5 20.6 11.8 16.6 1.7 21.8 11.8 139 6 143 165 2.9 0.1 3.3 2.6 01/30/2007 13:20:00 17.5 2.2 21.8 12.6 17.4 2.2 21.8 12.2 16.9 2.3 22.1 11.1 138 7 147 165 2.9 0.2 3.3 2.3 01/30/2007 13:30:00 18.5 1.7 22.1 14.5 18.3 1.8 22.1 14.5 18.1 2 22.9 13.3 139 6 129 165 2.9 0.1 3.3 2.3 01/30/2007 13:40:00 15.7 1.4 19.1 11.5 15.7 1.4 19.1 11.1 15.4 1.5 19.1 10.3 139 5 131 165 2.9 0.1 3.3 2.6 01/30/2007 13:50:00 15.1 1 18.3 12.2 15 1 18.3 11.8 14.9 1.2 17.9 11.5 141 5 135 165 2.9 0.1 3.3 2.3 01/30/2007 14:00:00 14.7 1.1 17.6 11.8 14.6 1.1 17.2 11.5 14.4 1.2 17.6 11.5 143 5 145 165 2.9 0.1 3 2.3 01/30/2007 14:10:00 16.1 1.3 19.9 13.3 16 1.3 19.5 13.3 15.7 1.3 18.7 12.6 145 5 145 165 2.9 0.1 3.3 2.6 01/30/2007 14:20:00 17 1.2 21 13.3 16.9 1.2 20.6 13 16.7 1.4 20.6 11.5 145 5 147 165 3 0.1 3.3 2.6 01/30/2007 14:30:00 17 1.1 19.5 13.7 16.8 1.1 19.1 13.7 16.5 1.3 19.9 12.2 146 3 145 165 3 0.1 3.3 2.6 01/30/2007 14:40:00 17.3 0.9 19.5 14.5 17.1 0.8 19.1 14.5 16.9 1 19.5 14.1 145 3 145 165 3 0.1 3.3 2.6 01/30/2007 14:50:00 17.9 1 19.9 14.5 17.6 1 19.5 14.1 17.4 1.2 19.9 12.6 147 3 148 165 2.9 0.1 3.3 2.3 01/30/2007 15:00:00 16.5 1.3 19.1 13 16.3 1.3 19.1 12.6 16.1 1.5 18.7 11.5 147 3 150 165 3 0.1 3.3 2.6 01/30/2007 15:10:00 16.2 0.8 18.3 13.7 16 0.8 17.9 13.7 15.7 1 18.3 12.2 145 4 143 165 2.9 0 3.3 2.6 01/30/2007 15:20:00 15.6 1.1 18.7 11.5 15.5 1.1 17.9 11.8 15.2 1.3 18.3 11.5 145 3 151 165 3 0 3.3 2.8 01/30/2007 15:30:00 15.2 1.1 17.6 12.6 15 1.1 17.6 12.2 14.7 1.2 17.2 11.8 147 3 148 165 3 0.1 3.3 2.6 01/30/2007 15:40:00 13.8 1.5 16.8 9.5 13.6 1.5 16.8 9.5 13.3 1.6 16.4 9.5 147 4 150 165 3 0 3.3 2.8 01/30/2007 15:50:00 13.5 0.8 15.3 11.1 13.3 0.8 14.9 11.1 13 0.9 15.3 9.5 146 3 147 165 3 0 3.3 2.6 01/30/2007 16:00:00 14.3 1.1 17.2 11.8 14.1 1.1 17.2 11.8 13.8 1.3 16.8 9.9 147 3 148 165 3 0.1 3.3 2.6 01/30/2007 16:10:00 12.8 1.2 15.6 9.1 12.8 1.2 15.3 9.1 12.2 1.4 15.6 8 143 4 150 165 3 0 3.3 2.8 01/30/2007 16:20:00 13.5 1.7 16.8 7.6 13.4 1.7 16.4 8 13.1 1.8 16.4 8.4 144 6 151 165 3.1 0 3.3 2.8 01/30/2007 16:30:00 12.8 1.1 15.3 9.5 12.8 1.2 15.3 9.5 12.5 1.3 14.9 8.4 144 4 145 165 3 0 3.3 2.8 01/30/2007 16:40:00 11.8 1.9 16.1 6.8 11.8 1.9 16.4 6.8 11.2 2.1 16.4 5.7 141 6 144 165 3 0 3.3 2.6 01/30/2007 16:50:00 13.8 1.4 17.2 11.1 13.7 1.3 17.2 10.7 13.3 1.4 16.8 9.9 144 5 146 165 3 0 3.3 2.8 01/30/2007 17:00:00 12.8 1.4 15.3 8.8 12.7 1.4 15.3 8.8 12.4 1.4 14.9 8.4 145 5 146 165 3.1 0 3.3 2.8 01/30/2007 17:10:00 12.1 1.1 14.5 8.8 12 1.1 14.5 8.4 11.8 1.1 14.1 8.4 146 5 148 165 3.1 0 3.3 2.8 01/30/2007 17:20:00 11 1 13.3 7.6 10.9 1 13.3 7.6 10.7 1 13.3 7.2 144 7 143 165 3 0 3.3 2.8 01/30/2007 17:30:00 11.1 1.1 13.3 7.6 10.9 1.1 13 7.6 11 1.2 14.1 7.6 151 6 149 165 3.2 0 3.3 3 01/30/2007 17:40:00 9 1.4 13 5.7 8.9 1.3 12.6 6.1 8.6 1.5 12.6 4.6 146 12 150 165 3.1 0 3.3 2.8 01/30/2007 17:50:00 7.9 1.2 11.8 5.3 7.8 1.2 11.8 5.3 7.7 1.3 11.8 5.7 143 9 129 165 3.2 0 3.3 2.8 01/30/2007 18:00:00 8.3 1 10.7 5.3 8.2 1 10.7 4.9 8.1 1 10.7 5.3 140 9 135 165 3.2 0 3.5 2.8 01/30/2007 18:10:00 9.5 1.3 12.6 6.1 9.4 1.3 12.6 6.1 9.4 1.3 13 5.7 144 8 145 165 3.2 0 3.3 3 01/30/2007 18:20:00 8.9 1.1 12.2 5.7 8.8 1.1 12.2 5.7 8.7 1.2 12.2 5.7 140 8 134 165 3.1 0 3.3 2.8 01/30/2007 18:30:00 10.1 0.9 12.6 8.4 10.1 0.9 12.6 8 9.9 1 12.6 6.8 138 6 139 165 3.2 0 3.3 3 01/30/2007 18:40:00 9.8 1 12.6 6.5 9.6 1 12.6 7.2 9.5 1.1 12.6 7.2 141 7 140 165 3.2 0 3.3 3 01/30/2007 18:50:00 9.1 1 11.5 6.8 9 1 11.5 6.8 8.9 1 11.5 6.5 138 8 133 165 3.2 0 3.3 3 01/30/2007 19:00:00 9.2 0.8 11.5 6.5 9 0.8 11.5 6.5 8.8 0.9 11.5 6.5 140 7 145 165 3.2 0 3.3 2.8 01/30/2007 19:10:00 9.1 0.9 11.5 6.8 9 0.9 11.1 6.8 8.9 1 11.1 6.1 140 6 135 165 3.2 0 3.3 3 01/30/2007 19:20:00 9 1 11.1 5.7 9 1 11.1 6.1 8.8 1.1 11.1 5.7 140 11 145 165 3.1 0 3.3 2.8 01/30/2007 19:30:00 9.1 0.8 11.1 7.2 8.9 0.7 11.1 7.2 8.9 0.8 11.1 6.5 149 5 147 165 3.1 0 3.3 2.8 01/30/2007 19:40:00 8.5 0.8 10.3 6.1 8.4 0.7 10.3 6.5 8 0.8 9.9 5.3 145 6 145 165 3 0 3.3 2.8 01/30/2007 19:50:00 7.9 0.8 10.3 6.1 7.9 0.7 9.9 6.5 7.8 0.7 9.9 5.7 145 6 153 165 3 0 3.3 2.8 01/30/2007 20:00:00 8.6 0.8 10.3 5.7 8.4 0.8 10.3 6.1 8.3 0.8 10.3 5.7 145 6 145 165 3 0 3.3 2.8 01/30/2007 20:10:00 9.2 1.2 12.2 6.5 9.1 1.1 12.2 6.8 9.1 1.2 12.2 5.7 148 5 145 165 3 0 3.3 2.8 01/30/2007 20:20:00 8.6 0.8 10.7 6.5 8.5 0.7 10.3 6.5 8.5 0.8 10.7 6.5 149 4 154 165 3 0.1 3.3 2.6 01/30/2007 20:30:00 8.6 0.6 10.3 6.8 8.5 0.6 10.3 6.5 8.3 0.6 9.9 6.5 147 5 136 165 3 0 3.3 2.8 01/30/2007 20:40:00 8.2 0.7 9.9 6.5 8.2 0.6 10.3 6.5 8 0.7 9.9 6.1 144 6 137 165 3 0 3.3 2.8 01/30/2007 20:50:00 8.5 0.8 10.3 5.7 8.5 0.8 9.9 6.1 8.3 0.7 9.9 6.5 143 6 140 165 3 0.2 3.3 2.6 01/30/2007 21:00:00 8.5 0.8 10.7 6.5 8.4 0.8 10.3 6.1 8.3 0.9 10.3 6.1 142 6 151 165 3 0.1 3.3 2.6 01/30/2007 21:10:00 10 1 13 7.2 9.9 1 12.6 7.2 9.7 1 12.2 6.8 140 7 143 165 3 0.1 3.3 2.6 01/30/2007 21:20:00 10.5 0.8 13 8.4 10.4 0.7 13 8 10.2 0.8 12.2 7.2 143 6 151 165 3 0.1 3.3 2.6 01/30/2007 21:30:00 9.6 0.8 11.8 7.2 9.5 0.8 11.5 7.2 9.3 0.9 11.5 6.5 144 6 142 165 3 0 3.3 2.6 01/30/2007 21:40:00 9.7 1 12.2 6.8 9.6 0.9 12.2 6.8 9.4 0.9 11.8 6.5 142 6 148 165 3 0 3.3 2.8 01/30/2007 21:50:00 10.7 0.9 13.3 8 10.6 1 13 7.6 10.2 1 13 7.2 140 6 140 165 3 0 3.3 2.8 01/30/2007 22:00:00 10.8 0.8 13.3 9.1 10.7 0.8 13 8.8 10.3 0.9 13.3 8 140 6 143 165 3 0 3.3 2.8 01/30/2007 22:10:00 11.7 0.8 13.7 9.1 11.5 0.8 13.7 9.1 11.2 1 14.1 8 140 6 137 165 3.1 0 3.3 2.8 01/30/2007 22:20:00 11.9 1.1 14.9 8.8 11.9 1.1 14.9 8.8 11.6 1.2 14.5 8 141 5 141 165 3.1 0 3.3 2.8 01/30/2007 22:30:00 12.2 1.1 15.3 9.1 12.1 1.1 15.3 8.4 11.8 1.2 14.9 6.8 141 6 135 165 3.1 0 3.3 3 01/30/2007 22:40:00 12.6 1 15.3 9.5 12.4 1 14.9 9.5 12.4 1 14.9 9.5 141 5 148 165 3.2 0 3.3 3 01/30/2007 22:50:00 12.1 1.2 15.3 8.8 12 1.2 14.9 8.4 11.8 1.3 16.1 8 140 7 145 165 3.1 0 3.3 3 01/30/2007 23:00:00 12.3 1.2 14.9 8 12.2 1.2 15.3 8 12 1.1 14.5 9.1 140 6 132 165 3.2 0 3.3 3 01/30/2007 23:10:00 12 1.2 14.9 8.8 11.9 1.2 15.3 9.1 11.4 1.3 14.9 7.6 136 6 117 165 3.2 0 3.3 3 01/30/2007 23:20:00 13 1.2 15.6 9.5 12.9 1.2 15.6 9.1 12.5 1.3 15.6 9.1 137 7 138 165 3.2 0 3.3 2.8 01/30/2007 23:30:00 12.7 1 15.6 9.9 12.6 1.1 15.6 9.5 12.4 1.3 15.6 8.4 136 6 137 165 3.2 0 3.3 3 01/30/2007 23:40:00 13 1.2 15.6 9.9 12.9 1.2 15.6 9.9 12.6 1.2 15.6 9.1 135 6 135 165 3.2 0 3.3 2.8 01/30/2007 23:50:00 13.2 1.3 16.4 9.5 13.2 1.3 16.4 9.9 12.5 1.6 16.1 7.6 136 7 139 165 3.2 0 3.3 2.8 01/31/2007 00:00:00 13.3 1.1 16.4 10.7 13.3 1.1 16.8 11.1 12.9 1.3 16.4 9.9 136 7 122 165 3.2 0 3.5 2.8 01/31/2007 00:10:00 13 1.2 16.1 9.9 13 1.2 16.4 9.1 12.5 1.4 15.6 8 134 8 122 165 3.1 0.1 3.3 2.6 01/31/2007 00:20:00 11.9 1.2 14.9 9.1 11.8 1.2 15.3 8.8 11.3 1.3 14.5 8 136 7 135 165 3.1 0.1 3.5 2.6 01/31/2007 00:30:00 11.8 1.3 15.3 8.4 11.7 1.3 15.6 8.4 11.3 1.3 14.5 7.6 135 7 124 165 3.1 0.1 3.3 2.8 01/31/2007 00:40:00 12.2 1.2 15.3 9.1 12.2 1.3 15.3 9.1 11.7 1.5 15.6 8.4 132 7 129 165 3.2 0 3.5 2.8 01/31/2007 00:50:00 12.7 1.3 16.8 9.5 12.7 1.3 16.8 9.5 12.3 1.5 16.1 8.4 133 6 123 165 3.2 0 3.5 2.8 01/31/2007 01:00:00 12.7 1.1 15.3 9.5 12.6 1.1 15.3 9.5 12.2 1.2 14.9 9.1 134 7 122 165 3.2 0 3.3 2.8 01/31/2007 01:10:00 12.6 1.2 15.6 9.1 12.6 1.2 16.1 9.1 12 1.3 15.3 8.4 134 7 129 165 3.1 0 3.5 2.8 01/31/2007 01:20:00 12.2 1 14.9 9.5 12.2 1 14.9 9.1 11.6 1.1 14.5 8.8 134 7 134 165 3.1 0.1 3.3 2.8 01/31/2007 01:30:00 10.6 0.8 13 7.6 10.6 0.8 13 8 10.4 0.8 12.6 6.5 135 7 126 165 3.1 0.1 3.5 2.8 01/31/2007 01:40:00 10.3 0.9 13.3 8.4 10.3 0.9 13.7 8 9.9 1 12.6 7.2 133 6 130 165 3.1 0.1 3.3 2.8 01/31/2007 01:50:00 10.2 0.8 12.2 8 10.2 0.8 12.2 7.6 9.8 0.9 12.2 6.5 134 7 130 165 3 0.2 3.3 2.6 01/31/2007 02:00:00 10.5 0.9 14.1 8 10.5 0.9 13.7 7.6 10.3 1.1 13.7 7.2 133 8 127 165 3 0.1 3.3 2.6 01/31/2007 02:10:00 9.6 1.3 13.3 6.5 9.5 1.3 13 6.5 9.3 1.4 13.7 6.1 133 8 135 165 2.9 0.2 3.3 2.3 01/31/2007 02:20:00 11.2 1.3 14.1 6.5 11.2 1.3 14.1 6.5 10.9 1.3 13.7 6.1 135 7 128 165 2.9 0.2 3.3 2.3 01/31/2007 02:30:00 10.1 1.2 13 7.2 10 1.1 12.6 7.6 9.8 1.2 13.3 6.8 133 9 136 165 2.9 0 3.3 2.8 01/31/2007 02:40:00 11.2 1.1 13.7 8.8 11.1 1.2 14.1 8.4 10.9 1.1 13.7 7.6 136 7 135 165 2.9 0 3 2.6 01/31/2007 02:50:00 10.1 1.7 13.7 6.5 10 1.7 13.7 6.1 9.8 1.7 13.3 6.1 138 8 139 165 2.9 0 3 2.6 01/31/2007 03:00:00 10.6 1.2 14.1 7.6 10.6 1.1 14.1 7.6 10.2 1.2 13.7 7.2 132 7 129 165 2.8 0 3 2.3 01/31/2007 03:10:00 9.7 1 12.2 6.8 9.6 1 12.2 7.2 9.3 1 12.2 7.2 134 8 136 165 2.7 0 2.8 2.3 01/31/2007 03:20:00 9.7 1.2 13.3 6.8 9.7 1.2 13.3 6.5 9.3 1.2 13 6.1 131 7 123 165 2.6 0 2.8 2.1 01/31/2007 03:30:00 10.3 0.9 12.6 8 10.2 0.9 12.2 8 10 1 13 7.2 132 7 135 165 2.4 0.2 2.8 1.8 01/31/2007 03:40:00 10.4 0.9 13.7 7.6 10.3 0.9 13.3 7.6 10 1 13.3 6.8 130 6 132 165 2.4 0.1 2.6 1.8 01/31/2007 03:50:00 10.2 0.8 12.6 8 10.2 0.8 12.2 8 10 1 12.2 7.2 130 6 122 165 2.4 0.1 2.6 1.8 01/31/2007 04:00:00 11.5 1.5 14.9 8 11.4 1.5 14.9 8 11.2 1.6 14.9 6.5 136 8 136 165 2.4 0.1 2.6 1.8 01/31/2007 04:10:00 10.4 1 13 6.8 10.4 0.9 13 7.2 10 1 12.2 6.1 132 6 133 165 2.4 0.1 2.6 1.8 01/31/2007 04:20:00 10.4 1 13.3 8 10.3 1 13 8.4 10.1 1 13 7.6 134 6 108 165 2.4 0.1 2.6 1.8 01/31/2007 04:30:00 11.6 1 13.7 8 11.5 1 13.3 8.4 11.3 1 14.1 8 136 7 135 165 2.4 0.1 2.6 1.8 01/31/2007 04:40:00 11.2 1.1 13.7 8.8 11.2 1.2 13.7 8.4 10.9 1.1 13.3 8 141 6 145 165 2.4 0.1 2.6 1.8 01/31/2007 04:50:00 11.4 1 13.7 9.1 11.3 1 13.7 8.8 11.2 1.1 14.1 8.4 140 5 143 165 2.4 0.1 2.8 1.8 01/31/2007 05:00:00 9.9 0.9 12.2 8 9.8 0.9 11.8 8 9.7 0.9 12.2 7.2 141 6 147 165 2.4 0 2.8 2.1 01/31/2007 05:10:00 10.9 0.8 12.6 8.8 10.8 0.8 12.6 8.4 10.6 0.8 12.6 8.4 144 6 136 165 2.4 0 2.6 2.1 01/31/2007 05:20:00 10.1 0.7 11.8 8.4 9.9 0.7 11.8 8 9.9 0.8 11.8 8 144 5 140 165 2.4 0 2.6 2.1 01/31/2007 05:30:00 10.5 1.2 13 8 10.4 1.3 13 8 10.3 1.2 13 8 139 7 139 165 2.5 0 2.8 2.3 01/31/2007 05:40:00 10.3 1.2 13 7.2 10.2 1.2 13 7.2 10.1 1.2 12.6 6.8 137 6 130 165 2.5 0 2.8 2.1 01/31/2007 05:50:00 11.4 1.3 14.5 8.8 11.3 1.3 14.5 8.4 11 1.3 14.9 8 138 6 135 165 2.4 0 2.8 2.3 01/31/2007 06:00:00 11.8 1 13.7 9.1 11.7 1 13.3 8.8 11.5 1 14.1 9.1 139 5 139 165 2.4 0 2.8 2.3 01/31/2007 06:10:00 9.9 1 11.8 7.2 9.8 1 11.8 7.2 9.7 1 11.8 6.5 140 8 142 165 2.4 0 2.6 2.3 01/31/2007 06:20:00 10.2 0.9 12.2 7.2 10.1 0.9 12.2 7.2 9.9 0.9 11.5 6.5 140 5 136 165 2.5 0 2.8 2.3 01/31/2007 06:30:00 9.5 0.8 11.5 7.2 9.4 0.8 11.5 7.2 9.3 0.9 11.1 6.8 140 8 136 165 2.4 0 2.8 2.3 01/31/2007 06:40:00 9.8 0.8 11.8 7.6 9.8 0.8 11.8 7.6 9.6 0.9 11.8 7.6 138 7 124 165 2.5 0 2.8 2.3 01/31/2007 06:50:00 9.6 0.8 11.5 7.6 9.5 0.8 11.5 7.2 9.3 0.8 11.8 7.2 138 6 141 165 2.5 0 2.8 2.3 01/31/2007 07:00:00 9.6 0.9 11.8 7.6 9.5 0.9 11.5 7.2 9.4 0.9 11.5 6.5 139 6 127 165 2.5 0 2.8 2.3 01/31/2007 07:10:00 10.3 1.3 13 7.2 10.2 1.3 13 6.8 10 1.4 13 6.8 138 7 135 165 2.5 0 2.8 2.3 01/31/2007 07:20:00 10.5 1 12.6 7.6 10.4 1 12.6 7.6 10.3 1 12.6 7.6 142 6 151 165 2.5 0 2.8 2.3 01/31/2007 07:30:00 9.6 1 12.2 7.6 9.5 1 11.8 7.6 9.5 1 12.6 7.2 140 6 141 165 2.5 0 2.8 2.3 01/31/2007 07:40:00 9.5 1.1 11.8 6.5 9.4 1.1 11.5 6.5 9.4 1.1 11.8 6.8 141 5 137 165 2.5 0 2.8 2.3 01/31/2007 07:50:00 9.4 0.7 11.5 7.6 9.3 0.7 11.5 7.6 9.2 0.9 12.2 6.5 135 8 129 165 2.5 0 2.8 2.3 01/31/2007 08:00:00 9 0.8 11.5 7.2 8.9 0.8 11.5 7.2 8.8 0.9 11.5 6.5 141 6 147 165 2.5 0.1 2.8 2.3 01/31/2007 08:10:00 9.1 0.8 11.1 6.8 9.1 0.8 11.1 6.8 8.8 0.8 11.1 6.5 138 7 134 165 2.4 0 2.8 2.3 01/31/2007 08:20:00 9.8 0.9 12.2 7.2 9.7 0.9 11.8 6.8 9.4 1 11.8 6.5 136 5 133 165 2.5 0 2.8 2.3 01/31/2007 08:30:00 10.1 1.2 13 7.2 10.1 1.2 13.3 7.2 9.8 1.3 13.3 6.8 138 7 138 165 2.5 0 2.8 2.3 01/31/2007 08:40:00 10.2 1 12.6 7.6 10.1 1 12.2 7.2 10 0.9 12.6 7.2 142 7 135 165 2.5 0 2.8 2.3 01/31/2007 08:50:00 10.2 1.1 12.2 7.6 10.1 1.1 12.6 7.2 10.1 1 12.6 7.6 143 6 132 165 2.6 0 2.8 2.3 01/31/2007 09:00:00 9.1 0.8 11.1 6.8 8.9 0.8 10.7 6.8 8.9 0.9 11.5 6.5 144 6 143 165 2.6 0 3 2.6 01/31/2007 09:10:00 8.7 0.9 10.7 6.8 8.5 0.8 10.7 6.5 8.4 0.8 10.7 6.8 142 6 139 165 2.6 0.1 2.8 2.1 01/31/2007 09:20:00 9.9 0.8 11.8 7.6 9.8 0.8 11.8 7.6 9.7 0.8 11.8 6.8 142 6 142 165 2.6 0.2 2.8 1.8 01/31/2007 09:30:00 9.9 0.9 12.2 8 9.8 0.9 12.2 7.6 9.7 1 11.8 6.5 141 5 140 165 2.5 0.2 2.8 1.8 01/31/2007 09:40:00 9.5 0.9 12.2 7.2 9.5 0.9 12.2 7.6 9.2 0.9 11.8 6.1 139 6 137 165 2.5 0.2 2.8 1.8 01/31/2007 09:50:00 9.7 0.7 11.8 8 9.6 0.7 11.8 8 9.5 0.8 11.8 6.8 139 6 136 165 2.4 0.2 2.8 1.8 01/31/2007 10:00:00 9.3 1.2 12.2 6.8 9.3 1.2 12.6 6.8 9 1.4 13 5.3 137 6 145 165 2.5 0.2 2.8 1.8 01/31/2007 10:10:00 8.9 0.7 10.7 7.2 8.8 0.6 10.7 7.2 8.6 0.7 10.7 6.1 139 7 152 165 2.5 0.2 2.8 1.8 01/31/2007 10:20:00 9 0.7 10.7 7.2 8.9 0.7 10.7 6.8 8.7 0.7 10.7 6.5 141 6 135 165 2.5 0.2 2.8 1.8 01/31/2007 10:30:00 8.8 0.8 11.5 6.8 8.8 0.8 11.1 6.5 8.6 0.9 10.7 6.1 139 7 148 165 2.6 0.1 2.8 2.1 01/31/2007 10:40:00 8.8 1 11.8 5.7 8.8 1 11.8 6.1 8.7 1 11.5 6.1 137 7 121 165 2.6 0.1 2.8 2.1 01/31/2007 10:50:00 9 0.9 11.1 6.8 9 0.9 11.5 6.8 8.7 1 11.1 6.5 127 6 136 165 2.6 0.1 2.8 2.1 01/31/2007 11:00:00 9.3 0.7 11.8 7.2 9.4 0.7 11.5 7.6 9.2 0.8 11.5 7.6 126 5 124 165 2.7 0.2 3 2.3 01/31/2007 11:10:00 9.2 0.8 11.5 7.2 9.2 0.7 11.8 7.2 8.9 0.8 11.1 6.5 128 7 119 165 2.7 0.2 3 2.3 01/31/2007 11:20:00 9.8 0.8 12.2 7.2 9.8 0.8 11.8 6.8 9.6 0.8 11.8 7.2 129 7 135 165 2.7 0.1 3 2.3 01/31/2007 11:30:00 9.5 0.7 11.5 7.6 9.5 0.7 11.5 7.6 9.2 0.8 11.5 6.8 129 7 121 165 2.7 0.2 3 2.3 01/31/2007 11:40:00 9.8 0.9 12.6 7.2 9.8 0.9 12.6 7.2 9.6 1 12.2 6.8 136 6 137 165 2.6 0 2.8 2.3 01/31/2007 11:50:00 9.8 1 12.6 7.6 9.8 1 12.6 7.2 9.5 1 12.2 6.5 137 7 144 165 2.7 0 2.8 2.6 01/31/2007 12:00:00 10.3 0.8 12.2 8 10.3 0.8 12.2 7.6 10 0.9 12.6 6.8 131 6 129 165 2.7 0 2.8 2.6 01/31/2007 12:10:00 10.1 1 13 8 10 1 12.6 8 9.8 1 12.6 6.8 136 6 140 165 2.7 0 2.8 2.6 01/31/2007 12:20:00 9.1 0.8 10.7 7.2 9.1 0.8 10.7 7.2 9 0.8 10.7 7.2 142 6 146 165 2.7 0 2.8 2.6 01/31/2007 12:30:00 9.4 1 11.8 7.2 9.4 1 11.8 7.2 9.2 1 11.5 7.2 142 7 136 165 2.7 0 2.8 2.3 01/31/2007 12:40:00 11.7 1.2 14.9 8.8 11.6 1.2 14.5 8.4 11.3 1.2 14.9 8.4 140 6 138 165 2.7 0 2.8 2.3 01/31/2007 12:50:00 12.5 1 14.5 8.8 12.4 1 14.5 9.1 12.2 1 14.5 8.8 139 6 137 165 2.4 0 2.6 2.3 01/31/2007 13:00:00 10.6 1.1 13.7 8.4 10.5 1 13.3 8 10.4 1.1 13 6.8 142 7 145 165 2.4 0 2.6 2.3 01/31/2007 13:10:00 12.4 1.2 15.3 9.5 12.4 1.2 15.3 9.1 12.1 1.3 15.3 9.1 136 6 139 165 2.4 0.1 2.6 1.8 01/31/2007 13:20:00 12.8 0.9 15.3 10.3 12.8 0.9 15.3 9.9 12.6 0.9 14.9 9.9 139 6 141 165 2.3 0 2.6 1.8 01/31/2007 13:30:00 11.4 1 14.1 8 11.3 1 14.1 7.6 11.1 1.2 13.7 7.2 138 6 133 165 2.3 0 2.6 1.8 01/31/2007 13:40:00 10.8 0.8 12.6 8.8 10.7 0.8 12.2 8.4 10.4 0.9 12.2 7.6 138 6 137 165 2.3 0 2.6 2.1 01/31/2007 13:50:00 10.5 0.8 13.3 8.4 10.4 0.8 13 8.4 10.2 0.9 12.2 7.2 141 5 140 165 2.4 0 2.6 2.1 01/31/2007 14:00:00 10.6 0.8 13 8.4 10.5 0.8 13 8.4 10.2 0.9 13 7.6 139 5 142 165 2.4 0 2.6 1.8 01/31/2007 14:10:00 10.2 0.9 12.6 8 10.1 1 12.6 7.6 9.9 1 12.6 7.2 142 6 146 165 2.3 0 2.6 1.8 01/31/2007 14:20:00 9.2 0.8 11.1 7.2 9.1 0.8 11.1 7.2 9 0.9 11.5 7.2 132 6 136 165 2.3 0 2.6 1.8 01/31/2007 14:30:00 9.3 0.7 11.1 7.2 9.2 0.7 11.1 7.2 9 0.7 10.3 6.8 128 5 128 165 2.3 0 2.6 1.8 01/31/2007 14:40:00 8 0.9 10.3 5.3 8 0.9 10.3 5.7 7.7 1 10.3 5.3 130 9 125 165 2.2 0 2.6 1.8 01/31/2007 14:50:00 8.9 0.6 10.7 7.2 8.9 0.6 10.7 7.2 8.6 0.7 10.7 6.8 132 5 132 165 2.2 0 2.3 1.8 01/31/2007 15:00:00 8 0.7 9.9 6.5 8 0.6 9.5 6.1 7.8 0.8 9.5 5.7 133 7 139 165 2.2 0 2.3 1.8 01/31/2007 15:10:00 9.5 1.2 12.2 7.2 9.4 1.2 12.6 7.2 9.1 1.1 11.8 6.5 136 6 136 165 2.2 0 2.6 1.8 01/31/2007 15:20:00 10.1 0.6 11.8 8.4 10 0.6 11.5 8 9.8 0.8 11.8 6.8 137 6 137 165 2.2 0 2.3 1.8 01/31/2007 15:30:00 8.7 1 10.7 6.1 8.7 0.9 10.7 6.5 8.6 1 10.7 5.3 134 6 140 165 2.2 0 2.3 1.8 01/31/2007 15:40:00 8.3 0.8 10.7 6.5 8.3 0.8 10.7 6.5 8 1 10.3 5.3 131 6 126 165 2.2 0 2.3 1.8 01/31/2007 15:50:00 8.8 0.7 11.1 6.8 8.8 0.8 10.7 6.5 8.4 0.8 11.1 6.1 129 6 129 165 2.1 0 2.3 1.6 01/31/2007 16:00:00 8.2 0.8 10.3 6.5 8.3 0.8 10.3 6.1 7.9 0.8 10.7 5.3 125 8 123 165 2.1 0 2.3 1.6 01/31/2007 16:10:00 7.3 0.9 9.5 4.9 7.4 1 9.5 4.9 6.9 0.9 8.8 4.2 117 5 111 165 2.1 0 2.3 1.6 01/31/2007 16:20:00 9.7 1 11.8 7.6 9.9 1 12.2 7.2 9.1 1 11.5 5.7 115 5 123 165 2.1 0 2.3 1.6 01/31/2007 16:30:00 9.1 0.8 11.1 5.7 9.2 0.8 11.5 6.1 8.8 0.9 11.1 6.5 114 6 114 165 2.2 0 2.6 1.8 01/31/2007 16:40:00 8.6 0.8 10.3 6.1 8.6 0.7 10.3 6.5 8.3 0.8 10.3 5.3 125 6 133 165 2.2 0 2.6 1.8 01/31/2007 16:50:00 8.2 0.9 9.9 5.7 8.3 0.9 9.9 6.1 7.8 1 9.5 5.3 118 5 121 165 2.1 0 2.3 1.6 01/31/2007 17:00:00 7.8 0.8 9.9 6.1 8 0.8 9.5 5.7 7.4 0.9 9.5 4.9 114 6 116 165 2.2 0 2.8 1.6 01/31/2007 17:10:00 7.7 0.6 9.1 5.7 7.9 0.5 9.1 6.1 7.3 0.7 9.1 5.3 109 5 114 165 2.2 0 2.3 1.8 01/31/2007 17:20:00 8.3 1 10.7 5.7 8.5 1 11.1 4.9 8 1.1 10.3 4.9 104 6 102 165 2.2 0 2.3 1.8 01/31/2007 17:30:00 9.3 0.8 11.1 6.8 9.5 0.8 11.5 7.2 8.9 1 11.1 6.1 107 5 105 165 2.2 0 2.3 1.8 01/31/2007 17:40:00 8.9 0.8 10.7 6.8 9.1 0.8 11.1 6.5 8.4 0.9 10.3 5.7 104 5 91 165 2.2 0 2.3 1.8 01/31/2007 17:50:00 9.3 1.5 12.2 6.1 9.5 1.5 12.6 6.5 8.9 1.6 11.8 4.9 105 6 107 165 2.3 0 2.6 1.8 01/31/2007 18:00:00 9.8 1 13 6.1 10 1 13.3 6.8 9.2 1.2 11.8 6.1 111 6 112 165 2.2 0 2.6 1.8 01/31/2007 18:10:00 9.8 1.1 12.6 6.8 10 1.1 12.6 6.8 9.4 1.2 12.2 6.5 109 8 116 165 2.2 0 2.3 1.8 01/31/2007 18:20:00 9.9 0.9 11.8 7.2 10.1 0.9 12.6 7.6 9.3 1.1 12.2 6.5 109 6 107 165 2.2 0 2.3 1.8 01/31/2007 18:30:00 9.6 1.4 12.6 4.9 9.8 1.4 12.6 5.3 9.1 1.6 12.2 5.3 108 7 105 165 2.1 0 2.3 1.8 01/31/2007 18:40:00 9.9 0.8 11.8 7.2 10.1 0.8 11.8 7.2 9.4 1 11.5 6.8 112 5 112 165 2.1 0 2.3 1.8 01/31/2007 18:50:00 9.8 1 12.2 7.6 10 1 12.6 7.6 9.3 1.2 12.2 6.5 112 6 108 165 2.1 0 2.3 1.6 01/31/2007 19:00:00 9.8 1 11.8 7.2 9.9 1 12.2 7.6 9.2 1.2 12.2 5.3 112 7 105 165 2.1 0 2.3 1.8 01/31/2007 19:10:00 9.1 0.8 11.1 6.5 9.2 0.8 11.1 6.8 8.7 1 11.1 6.1 111 6 114 165 2.1 0 2.3 1.8 01/31/2007 19:20:00 8.9 1.1 11.8 4.9 9.1 1.1 11.8 5.7 8.4 1.3 11.5 5.3 111 6 101 165 2 0 2.3 1.6 01/31/2007 19:30:00 9.8 0.7 11.5 7.6 10 0.8 11.8 8 9.3 1 11.5 6.5 111 5 116 165 2 0 2.3 1.6 01/31/2007 19:40:00 9.3 1 11.8 6.1 9.5 1 12.2 6.1 8.8 1 11.1 5.3 110 5 110 165 2 0 2.3 1.8 01/31/2007 19:50:00 9.4 0.6 11.5 7.6 9.7 0.6 11.8 7.6 9.1 0.8 10.7 6.1 107 5 104 165 2 0 2.3 1.6 01/31/2007 20:00:00 9.7 1.3 12.2 6.1 9.9 1.3 12.6 6.1 9.2 1.5 12.2 4.9 104 6 95 165 1.9 0.1 2.3 1.4 01/31/2007 20:10:00 10.2 0.6 11.8 8.4 10.4 0.6 11.8 8 9.8 0.8 11.8 6.5 107 3 106 165 1.9 0.1 2.1 1.4 01/31/2007 20:20:00 8.5 1.3 11.5 5.7 8.7 1.3 11.8 5.7 7.9 1.3 11.8 4.6 110 6 111 165 1.9 0 2.1 1.4 01/31/2007 20:30:00 9.6 1.4 11.8 5.3 9.8 1.5 12.2 5.3 9 1.5 12.2 5.3 106 5 104 165 1.9 0.1 2.1 1.6 01/31/2007 20:40:00 9.8 0.6 11.8 8 9.9 0.6 12.2 8.4 9.4 0.8 11.8 6.8 107 4 96 165 1.9 0 2.1 1.6 01/31/2007 20:50:00 9.4 0.8 12.2 7.2 9.6 0.8 12.6 7.6 8.9 1 11.1 5.3 108 6 100 165 1.9 0 2.1 1.6 01/31/2007 21:00:00 9.5 1 11.8 6.8 9.7 1 11.8 6.8 8.9 1 11.1 5.3 107 5 106 165 1.9 0 2.1 1.6 01/31/2007 21:10:00 9 1.2 12.2 6.1 9.1 1.3 12.6 5.3 8.4 1.5 12.6 4.6 109 6 108 165 1.9 0 2.1 1.6 01/31/2007 21:20:00 9.2 1.2 12.6 6.1 9.3 1.2 13 5.7 8.7 1.3 12.2 5.7 111 7 112 165 1.9 0 2.1 1.6 01/31/2007 21:30:00 9.5 0.8 11.8 7.6 9.7 0.8 11.8 7.6 9.1 1 11.8 6.5 106 5 104 165 1.9 0 2.1 1.6 01/31/2007 21:40:00 9.5 1 11.8 6.1 9.7 1 11.8 6.5 9 1.1 11.8 5.7 107 5 101 165 1.8 0 2.1 1.6 01/31/2007 21:50:00 10.4 1 12.2 7.2 10.6 1.1 12.6 7.2 9.9 1.2 12.6 6.1 106 5 106 165 1.8 0.1 1.8 1.4 01/31/2007 22:00:00 10.2 0.8 11.8 7.6 10.4 0.8 12.2 7.6 9.7 1 11.8 6.5 106 4 108 165 1.8 0 2.1 1.6 01/31/2007 22:10:00 10.2 0.7 12.6 7.6 10.3 0.7 13 8 9.6 1 12.6 6.8 109 6 107 165 1.8 0 1.8 1.6 01/31/2007 22:20:00 10.3 1.1 13.3 6.8 10.4 1.1 13 7.2 9.6 1.2 12.2 6.1 108 5 119 165 1.8 0.1 1.8 1.4 01/31/2007 22:30:00 10.4 0.7 12.6 8.4 10.6 0.7 12.6 8.8 10.1 0.9 12.6 7.2 107 5 111 165 1.8 0.1 1.8 1.4 01/31/2007 22:40:00 11.1 0.8 13.3 8 11.3 0.9 13.7 8 10.7 1 13.3 8.4 109 5 108 165 1.7 0 1.8 1.4 01/31/2007 22:50:00 9.3 1.2 11.5 5.3 9.5 1.1 11.8 6.5 8.8 1.2 11.5 6.1 114 5 116 165 1.7 0 1.8 1.4 01/31/2007 23:00:00 10.2 1 13 6.5 10.4 1 13.3 6.1 9.6 1.2 11.8 5.7 110 5 107 165 1.7 0 1.8 1.4 01/31/2007 23:10:00 9.7 0.8 11.5 7.2 9.9 0.8 11.8 7.6 9.3 1 11.8 6.8 115 5 110 165 1.7 0 1.8 1.4 01/31/2007 23:20:00 8.7 0.9 11.1 6.1 8.8 1 11.1 6.1 8.1 1 10.7 5.7 114 7 107 165 1.7 0 1.8 1.4 01/31/2007 23:30:00 9.7 0.9 11.8 7.2 9.9 0.9 12.2 7.2 9.2 1 11.8 5.7 111 6 112 165 1.7 0 1.8 1.4 01/31/2007 23:40:00 9.6 0.6 10.7 7.2 9.7 0.6 11.1 7.6 9 0.8 10.7 6.5 112 5 126 165 1.7 0 1.8 1.4 01/31/2007 23:50:00 9.6 0.8 11.8 7.6 9.8 0.8 12.2 7.6 9.1 1.2 11.8 6.1 112 5 116 165 1.6 0 1.8 1.4 02/01/2007 00:00:00 9.6 0.8 11.5 7.2 9.8 0.8 11.5 7.6 9 0.9 11.5 6.5 113 5 114 165 1.7 0 1.8 1.4 02/01/2007 00:10:00 8.4 0.8 10.7 6.1 8.5 0.8 11.1 5.7 7.9 0.9 10.3 5.3 115 6 114 165 1.7 0 1.8 1.4 02/01/2007 00:20:00 9.2 0.8 11.1 6.8 9.4 0.9 11.5 6.8 8.6 0.9 11.1 6.1 114 6 109 165 1.7 0 1.8 1.4 02/01/2007 00:30:00 9 1 11.5 6.1 9.1 1 11.1 6.5 8.4 1.1 10.3 5.3 117 6 114 165 1.6 0 1.8 1.4 02/01/2007 00:40:00 9.8 1 12.2 7.2 10 0.9 12.2 7.2 9.4 1 12.2 6.8 115 6 109 165 1.6 0 1.8 1.4 02/01/2007 00:50:00 9.7 1.1 12.2 6.8 9.8 1.1 12.2 7.2 9.5 1 11.8 6.5 118 6 119 165 1.6 0 1.8 1.4 02/01/2007 01:00:00 9.2 1 12.2 6.1 9.4 1 12.2 6.5 8.8 1 12.2 6.5 117 5 117 165 1.6 0 1.8 1.1 02/01/2007 01:10:00 8.9 1 11.1 6.5 9 1 11.5 6.5 8.5 1 11.1 5.7 117 6 116 165 1.5 0 1.8 0.9 02/01/2007 01:20:00 9.2 0.8 11.8 6.8 9.4 0.8 11.5 7.2 8.7 0.9 11.1 5.7 117 5 117 165 1.5 0 1.6 0.9 02/01/2007 01:30:00 9.1 0.9 11.5 6.5 9.3 0.9 11.5 6.1 8.7 1 11.1 5.7 115 7 114 165 1.5 0 1.6 1.1 02/01/2007 01:40:00 9.9 0.8 11.5 7.6 10.1 0.8 11.8 7.6 9.6 0.8 11.8 7.2 110 4 110 165 1.5 0.1 1.6 0.9 02/01/2007 01:50:00 9.5 0.8 11.5 7.2 9.7 0.8 11.5 7.2 9.1 1 11.1 5.7 112 5 112 165 1.5 0 1.6 1.1 02/01/2007 02:00:00 10.1 0.8 11.8 7.2 10.3 0.8 11.8 7.6 9.6 0.9 11.8 6.5 108 6 111 165 1.5 0.1 1.6 0.9 02/01/2007 02:10:00 9.2 0.6 10.7 7.2 9.4 0.6 11.1 6.8 8.4 0.8 10.7 5.7 113 4 111 165 1.4 0.1 1.6 0.9 02/01/2007 02:20:00 9.4 0.7 11.5 7.6 9.6 0.7 11.8 7.6 9 0.8 11.1 6.5 110 5 114 165 1.5 0 1.6 0.9 02/01/2007 02:30:00 9.7 1 11.8 6.8 9.9 1 11.8 7.2 9.2 1 11.5 5.7 112 6 112 165 1.5 0 1.6 0.9 02/01/2007 02:40:00 9.1 0.9 11.1 6.8 9.3 1 11.5 6.5 8.6 1.1 10.3 5.3 107 6 110 165 1.5 0 1.6 0.9 02/01/2007 02:50:00 9.8 0.7 11.5 7.2 10 0.8 12.2 8 9.3 1 12.2 6.5 107 5 112 165 1.5 0 1.6 1.4 02/01/2007 03:00:00 9.5 0.8 12.2 7.2 9.6 0.8 11.8 7.2 8.9 0.9 11.5 6.1 114 5 122 165 1.5 0 1.6 1.1 02/01/2007 03:10:00 9.9 0.8 11.5 7.6 10.1 0.8 11.8 7.6 9.3 1 11.5 6.8 108 5 110 165 1.5 0 1.6 1.1 02/01/2007 03:20:00 9.3 1.1 12.6 6.8 9.5 1.1 12.6 6.1 8.7 1.2 11.5 6.1 109 6 107 165 1.5 0 1.8 1.4 02/01/2007 03:30:00 8.8 0.8 11.5 6.1 9 0.8 11.5 6.5 8.3 1 11.1 5.3 113 5 113 165 1.5 0 1.6 1.4 02/01/2007 03:40:00 9.5 1.1 11.8 6.8 9.7 1.1 12.2 6.8 9.1 1.3 12.6 5.3 104 5 105 165 1.6 0 1.8 1.4 02/01/2007 03:50:00 9.9 0.9 12.2 6.1 10.1 0.9 12.2 6.8 9.4 1 11.8 6.8 105 5 102 165 1.6 0 1.8 1.4 02/01/2007 04:00:00 9.8 1.4 13 6.5 10 1.5 13.3 6.5 9.2 1.4 13 5.7 102 6 101 165 1.5 0 1.8 0.9 02/01/2007 04:10:00 10.2 1 13 7.2 10.4 1 13 7.6 9.5 1.2 12.6 6.8 105 5 102 165 1.4 0 1.6 0.9 02/01/2007 04:20:00 10 1.2 13.7 6.8 10.3 1.2 14.1 7.6 9.5 1.3 13 6.8 109 7 113 165 1.5 0 1.6 1.4 02/01/2007 04:30:00 10.3 1.2 13.3 7.2 10.4 1.2 13.3 7.2 9.7 1.3 13 6.5 113 6 113 165 1.5 0.1 1.6 0.9 02/01/2007 04:40:00 11.3 1.1 13.3 8.4 11.3 1.1 13.3 8.4 10.7 1.3 13.7 6.8 108 5 110 165 1.5 0 1.6 0.9 02/01/2007 04:50:00 11 1.1 13.7 7.6 10.8 1.1 13.3 7.6 10.4 1.2 13 7.2 116 6 112 165 1.5 0 1.6 1.1 02/01/2007 05:00:00 9.5 0.8 11.5 7.2 9.4 0.8 11.5 6.5 9.2 0.9 11.5 6.5 119 6 123 165 1.5 0 1.6 0.9 02/01/2007 05:10:00 9.9 1.3 12.6 6.8 9.6 1.2 12.2 6.8 9.4 1.4 12.6 5.7 116 6 113 165 1.5 0 1.6 1.1 02/01/2007 05:20:00 10.5 0.9 12.2 6.8 10 0.8 11.5 6.8 9.9 1 12.2 7.2 116 5 113 165 1.5 0 1.6 1.1 02/01/2007 05:30:00 9.9 1.2 12.2 6.8 9.3 1.1 11.8 6.5 9.3 1.3 11.8 5.7 117 6 112 165 1.5 0 1.6 1.1 02/01/2007 05:40:00 8.6 1 11.5 6.1 8 1 10.7 6.1 7.9 1.3 11.5 4.9 113 8 123 165 1.5 0 1.6 1.1 02/01/2007 05:50:00 8.6 1.2 11.1 5.7 7.9 1.1 10.3 5.3 7.9 1.2 10.7 4.6 106 7 96 165 1.5 0 1.6 1.1 02/01/2007 06:00:00 9.5 1 11.8 6.5 8.7 0.9 10.7 5.3 9.2 1 11.8 6.1 114 9 103 165 1.5 0 1.6 1.1 02/01/2007 06:10:00 9.6 1.2 12.6 6.8 8.6 1.1 11.5 6.1 9 1.3 13 5.7 113 6 105 165 1.5 0 1.6 0.9 02/01/2007 06:20:00 10.2 0.9 12.6 8 9.1 0.8 11.1 7.2 9.9 0.9 11.8 7.2 107 4 108 165 1.5 0 1.6 1.1 02/01/2007 06:30:00 9.9 1.3 12.6 6.8 8.8 1.1 10.7 6.1 9.4 1.3 12.2 5.3 102 6 96 165 1.5 0 1.6 1.1 02/01/2007 06:40:00 10.8 1.2 14.5 7.6 9.5 1 12.6 6.8 10.4 1.5 14.1 6.8 109 4 100 165 1.5 0 1.6 1.1 02/01/2007 06:50:00 10.6 1.3 13 6.8 9.2 1.1 11.1 6.1 10.2 1.5 13 5.3 112 1 112 165 1.5 0 1.6 0.9 02/01/2007 07:00:00 10.8 1.1 13.7 8 9.4 0.9 11.5 6.8 10.4 1.2 13.3 6.8 112 0 112 165 1.5 0.1 1.6 0.9 02/01/2007 07:10:00 11.1 0.8 13 8 9.7 0.7 11.5 6.8 10.8 1.1 13 8 112 0 112 165 1.4 0 1.6 0.9 02/01/2007 07:20:00 10.4 0.9 12.2 7.2 9.2 0.8 10.7 6.5 10.4 1.3 12.6 6.5 112 1 112 165 1.4 0 1.6 1.1 02/01/2007 07:30:00 9.9 1.3 13 6.8 8.9 1.1 11.5 6.5 10.1 1.5 13.7 6.1 112 1 112 165 1.5 0 1.6 1.1 02/01/2007 07:40:00 10.1 1 12.6 7.2 9.2 0.8 11.1 6.5 10.4 1.2 13 6.1 112 1 112 165 1.5 0 1.6 1.1 02/01/2007 07:50:00 10 0.8 11.5 7.6 9.2 0.6 10.7 6.8 10.3 1 12.2 7.2 112 1 112 165 1.4 0 1.6 1.1 02/01/2007 08:00:00 10.1 0.8 11.8 7.6 9.4 0.7 11.1 7.2 10.3 1 12.6 6.8 112 0 112 165 1.4 0 1.6 1.1 02/01/2007 08:10:00 9.1 1.2 11.8 6.1 8.3 1.2 11.1 4.9 9.3 1.5 12.6 6.1 112 0 112 165 1.5 0 1.6 1.4 02/01/2007 08:20:00 10 1.1 13 6.8 9.3 1 11.8 6.5 10.2 1.3 13 7.2 112 0 112 165 1.5 0 1.8 1.1 02/01/2007 08:30:00 10 1.1 12.6 6.5 9.2 1 11.5 6.1 10.4 1.2 13.7 6.5 112 0 112 165 1.5 0 1.6 1.4 02/01/2007 08:40:00 9.2 1.1 12.2 6.5 8.6 1 11.1 6.1 9.7 1.1 12.6 6.8 112 0 112 165 1.5 0 1.6 1.4 02/01/2007 08:50:00 8.2 0.8 9.9 6.1 7.6 0.7 9.1 5.3 8.4 1 10.7 5.3 112 0 112 165 1.5 0 1.8 1.4 02/01/2007 09:00:00 7.9 1.5 10.7 4.6 7.4 1.3 9.9 4.6 7.9 1.7 11.8 3.8 112 0 112 165 1.5 0 1.8 1.4 02/01/2007 09:10:00 8.6 1 11.1 6.5 8.1 0.8 10.3 6.1 8.9 1.1 11.8 6.1 112 0 112 165 1.5 0 1.8 1.4 02/01/2007 09:20:00 9 0.8 11.5 6.5 8.4 0.8 10.7 6.1 9.4 1 12.2 6.8 112 0 112 165 1.5 0 1.8 1.1 02/01/2007 09:30:00 8.4 0.9 10.7 6.1 7.8 0.8 10.3 6.1 8.6 1 11.1 6.1 112 0 112 165 1.5 0 1.8 1.4 02/01/2007 09:40:00 8.9 0.9 11.8 6.5 8.3 0.8 10.7 6.1 9.6 1 12.2 6.5 112 0 112 165 1.5 0 1.6 1.4 02/01/2007 09:50:00 8.8 0.8 10.7 6.8 8.3 0.7 10.3 6.8 9.4 1 11.5 7.2 112 0 112 165 1.5 0 1.8 1.4 02/01/2007 10:00:00 8.6 0.9 11.1 6.8 8 0.7 9.9 6.1 9.2 1.2 12.2 5.7 112 0 112 165 1.5 0 1.8 1.4 02/01/2007 10:10:00 8.7 1 11.5 5.7 8.2 0.9 9.9 5.7 9.3 1.1 11.8 6.5 112 1 112 165 1.5 0 1.6 1.4 02/01/2007 10:20:00 9 0.8 10.7 6.5 8.5 0.7 9.9 6.5 9.5 1.1 11.8 6.5 112 0 112 165 1.5 0 1.8 1.4 02/01/2007 10:30:00 9.3 1.2 12.2 6.8 8.7 1 11.1 6.1 10 1.4 13.3 6.8 112 1 112 165 1.5 0 1.6 1.4 02/01/2007 10:40:00 8.9 1 11.5 6.5 8.3 0.9 11.1 6.1 9.7 1.1 13 7.2 112 1 112 165 1.6 0 1.8 1.6 02/01/2007 10:50:00 9.7 0.9 11.5 7.2 9 0.7 11.1 6.8 10.4 1 13 7.2 111 1 111 165 1.7 0 1.8 1.6 02/01/2007 11:00:00 8.9 0.8 10.7 6.8 8.4 0.7 9.9 6.5 9.8 0.9 11.8 6.8 111 1 112 165 1.7 0.2 1.8 0.9 02/01/2007 11:10:00 7.8 1.1 10.3 4.9 7.3 0.9 9.1 4.9 8.6 1.2 11.1 5.3 111 1 111 165 1.9 0.2 2.3 1.4 02/01/2007 11:20:00 9.5 1.1 11.8 5.7 8.8 1 10.7 5.3 10.4 1.4 13.3 6.8 110 1 111 165 2 0 2.3 1.8 02/01/2007 11:30:00 11.7 1.4 14.9 8 10.6 1.2 13.7 7.2 12.2 1.7 17.2 8.4 109 1 110 165 2 0.2 2.3 1.4 02/01/2007 11:40:00 12 1.1 14.5 8.8 10.4 1 12.6 8 11.8 1.3 14.9 8 107 5 97 165 2 0 2.3 1.4 02/01/2007 11:50:00 12.4 1.5 16.1 8.8 10.6 1.3 13.7 7.6 11.8 1.5 16.1 8.4 100 5 100 165 1.9 0 2.1 1.4 02/01/2007 12:00:00 13 1 15.6 9.9 11.3 0.9 13.3 8.8 12.2 1.2 14.9 8.4 99 5 102 165 1.9 0 2.1 1.8 02/01/2007 12:10:00 12.1 1.7 15.6 8 10.6 1.5 13.7 6.8 11.5 1.7 14.9 7.6 93 7 99 165 1.9 0 2.1 1.8 02/01/2007 12:20:00 12.7 1.7 16.4 8.8 11.9 2.1 16.1 8 12.1 1.6 15.6 8.8 91 8 88 165 1.9 0.1 2.3 1.4 02/01/2007 12:30:00 13.1 1.2 16.4 9.9 13.2 1.3 16.4 9.5 12.2 1.4 15.6 8.8 99 6 98 165 1.8 0.2 2.1 1.4 02/01/2007 12:40:00 12.3 1.6 15.6 9.1 12.6 1.7 16.1 8.8 11.6 1.8 15.6 7.2 103 7 102 165 1.8 0.2 2.1 1.4 02/01/2007 12:50:00 13 1.3 16.1 8.4 13.2 1.3 16.1 8.8 12.3 1.3 15.6 9.5 100 6 98 165 1.8 0.1 2.1 1.4 02/01/2007 13:00:00 14.7 1.7 18.7 9.5 14.9 1.7 19.1 9.1 14 1.8 18.3 8.8 107 6 112 165 1.8 0.1 1.8 1.1 02/01/2007 13:10:00 14.5 1.4 17.6 10.3 14.7 1.5 17.9 9.9 13.6 1.7 17.6 8.8 107 4 116 165 1.8 0.1 2.1 1.4 02/01/2007 13:20:00 13.6 1.3 16.1 9.5 13.8 1.3 16.8 9.1 13 1.3 15.6 8.8 106 6 109 165 1.8 0.2 2.1 1.4 02/01/2007 13:30:00 14 1.2 16.4 10.3 14.2 1.3 16.4 10.3 13.4 1.4 16.4 8.8 106 6 111 165 1.8 0.2 2.1 1.4 02/01/2007 13:40:00 13.1 1.3 16.1 9.5 13.4 1.3 16.4 9.9 12.5 1.4 15.6 8.8 102 5 103 165 1.8 0.2 2.1 1.4 02/01/2007 13:50:00 13 1.2 16.1 8.8 13.3 1.3 16.1 9.1 12.2 1.4 15.6 8.4 98 6 100 165 1.8 0.2 2.3 1.4 02/01/2007 14:00:00 13 1.2 15.3 9.1 13.3 1.2 15.6 9.5 12.5 1.2 15.6 9.5 93 5 94 165 1.9 0.1 2.3 1.4 02/01/2007 14:10:00 13.4 1.7 16.4 8.4 13.7 1.7 16.8 8.4 12.8 1.7 16.4 8 97 6 107 165 1.9 0.1 2.3 1.4 02/01/2007 14:20:00 13.6 1.6 16.8 9.9 13.8 1.6 17.2 9.9 12.8 1.5 16.4 9.1 99 6 96 165 1.9 0.1 2.3 1.6 02/01/2007 14:30:00 14 1.2 17.2 11.1 14.3 1.2 17.6 11.1 13.3 1.4 16.8 9.1 100 5 101 165 1.9 0.1 2.3 1.4 02/01/2007 14:40:00 13.6 2 17.9 8.8 13.8 2 18.3 9.1 12.8 2.1 17.6 8 109 7 103 165 1.9 0.1 2.3 1.4 02/01/2007 14:50:00 14.1 1.4 18.3 10.7 14.4 1.4 18.3 11.1 13.4 1.4 17.2 9.9 106 6 96 165 1.9 0.1 2.1 1.6 02/01/2007 15:00:00 14.5 1.7 18.7 8.4 14.7 1.7 18.7 9.5 13.8 1.7 19.1 9.5 110 9 110 165 1.9 0 2.3 1.8 02/01/2007 15:10:00 12.7 1.9 18.3 8.4 12.8 2 18.7 8.4 12 2.2 19.1 6.8 112 8 113 165 1.8 0.2 2.3 1.4 02/01/2007 15:20:00 13.1 2.1 17.6 8 13.3 2.1 17.9 8 12.6 2.2 17.2 7.6 108 6 118 165 1.9 0.1 2.3 1.4 02/01/2007 15:30:00 12 1.3 15.3 8.8 12.2 1.4 15.6 8.8 11.6 1.4 14.9 7.6 109 6 112 165 1.9 0.2 2.3 1.4 02/01/2007 15:40:00 11.7 1.4 15.3 8 11.8 1.4 15.3 8 11.1 1.4 14.1 7.2 116 7 108 165 2.1 0.1 2.3 1.6 02/01/2007 15:50:00 11.9 2.2 16.4 6.1 11.9 2.2 16.4 6.1 11.3 2.3 15.6 5.3 120 8 125 165 2.1 0.1 2.6 1.8 02/01/2007 16:00:00 11.3 2 16.1 6.5 11.4 2 16.1 6.5 10.9 2.1 16.1 6.1 122 9 126 165 2.2 0.1 2.6 1.8 02/01/2007 16:10:00 11.3 1.4 14.5 8.4 11.4 1.5 14.9 7.6 10.8 1.7 14.5 6.1 117 9 124 165 2.3 0 2.6 2.1 02/01/2007 16:20:00 13.4 1.7 17.9 8.8 13.5 1.7 17.6 9.5 12.7 1.7 16.8 9.1 119 7 121 165 2.4 0 2.6 2.1 02/01/2007 16:30:00 13.4 2.1 18.7 9.5 13.5 2.1 18.7 9.5 12.9 2.1 17.9 9.1 121 7 116 165 2.3 0.1 2.6 1.8 02/01/2007 16:40:00 12.2 2 17.9 7.2 12.3 2 17.6 7.6 11.8 2 16.8 7.2 123 7 115 165 2.1 0.2 2.6 1.6 02/01/2007 16:50:00 13.9 1.7 19.9 8.8 14 1.8 19.9 9.9 13.4 1.9 19.1 9.1 125 7 115 165 2.2 0.1 2.6 1.6 02/01/2007 17:00:00 13.3 1.8 18.3 9.1 13.4 1.8 18.3 9.1 12.6 1.9 17.9 8.4 123 7 118 165 2.1 0.2 2.6 1.6 02/01/2007 17:10:00 13.7 2.2 18.3 8.4 13.7 2.3 18.7 8 13.3 2.5 18.7 8.4 126 8 122 165 2.4 0.1 2.6 1.8 02/01/2007 17:20:00 14.7 1.7 20.2 10.3 14.8 1.7 19.9 10.7 14.2 1.8 19.9 8.8 126 6 130 165 2.4 0 2.6 2.1 02/01/2007 17:30:00 15.5 1.7 19.9 9.9 15.5 1.7 19.9 9.5 15 1.7 19.9 9.9 126 8 118 165 2.4 0.1 2.6 2.1 02/01/2007 17:40:00 16.1 1.3 20.2 12.2 16.2 1.3 20.2 12.6 15.7 1.4 20.2 11.5 127 7 128 165 2.5 0 2.8 2.3 02/01/2007 17:50:00 17.2 2.4 23.3 11.1 17.2 2.4 23.3 11.5 16.5 2.5 22.6 9.5 130 8 136 165 2.6 0 2.8 2.3 02/01/2007 18:00:00 16.9 1.7 21.4 12.6 16.9 1.7 21.4 13 16.5 2.1 21 10.7 128 8 119 165 2.5 0 2.8 2.3 02/01/2007 18:10:00 18 2 22.9 12.6 18 2 22.6 13 17.4 2 22.6 11.8 131 8 139 165 2.4 0 2.8 2.1 02/01/2007 18:20:00 20.5 2.2 25.6 14.1 20.4 2.2 24.8 14.1 20 2.3 24.8 14.5 138 7 130 165 2.4 0 2.6 2.1 02/01/2007 18:30:00 21 1.5 24.4 16.4 21 1.5 24.4 16.1 20.8 1.6 26 16.4 142 5 130 165 2.1 0.1 2.6 1.6 02/01/2007 18:40:00 17.8 1.3 21.4 14.5 17.7 1.3 21 14.9 17.5 1.4 21.8 13.3 144 6 146 165 2.1 0.2 2.6 1.6 02/01/2007 18:50:00 18.2 1.6 21.8 11.8 18.1 1.6 22.1 12.2 17.9 1.7 21.8 11.8 140 6 142 165 2.6 0 2.8 2.1 02/01/2007 19:00:00 17.2 1.7 22.6 11.8 17.1 1.7 22.1 12.6 16.9 1.7 22.1 12.6 141 7 139 165 2.7 0 2.8 2.6 02/01/2007 19:10:00 19 1.5 21.8 13.7 18.9 1.5 21.8 14.1 18.8 1.7 21.8 12.6 142 7 148 165 2.7 0 2.8 2.6 02/01/2007 19:20:00 16.4 1.4 20.2 13.3 16.3 1.4 19.9 13 16.1 1.7 20.6 10.7 143 6 147 165 2.7 0 2.8 2.6 02/01/2007 19:30:00 14.1 1.5 17.9 10.3 14 1.5 17.9 9.9 13.5 1.4 17.2 9.9 139 7 135 165 2.7 0 3 2.6 02/01/2007 19:40:00 15.6 1.5 19.9 12.2 15.4 1.5 19.5 12.2 15.3 1.5 20.2 11.1 143 6 143 165 3 0 3.3 2.8 02/01/2007 19:50:00 16.1 1.5 19.5 11.8 16 1.5 19.5 11.5 15.6 1.5 19.1 11.1 138 6 136 165 3.2 0 3.5 3 02/01/2007 20:00:00 16.5 1.5 19.9 11.8 16.5 1.5 19.9 11.5 16.1 1.5 19.5 12.2 139 7 139 165 3.3 0 3.5 2.8 02/01/2007 20:10:00 17.1 1.6 21.4 12.2 17 1.6 21 12.2 16.5 1.7 22.1 11.8 139 6 140 165 3.5 0.1 3.8 2.8 02/01/2007 20:20:00 16 2 20.6 11.8 15.8 1.9 21 11.8 15.6 2 20.2 11.5 142 6 140 165 3.5 0 3.5 3.3 02/01/2007 20:30:00 13.7 1.1 17.2 10.7 13.6 1.1 17.2 10.7 13.4 1.2 16.4 9.9 146 5 147 165 3.3 0 3.8 2.8 02/01/2007 20:40:00 10.9 1.2 13 8 10.7 1.1 12.6 8 10.4 1.1 12.6 7.6 148 3 148 165 3.2 0 3.5 2.6 02/01/2007 20:50:00 8.4 0.8 10.3 7.2 8.1 0.8 10.3 6.8 8.2 0.7 10.3 6.8 152 3 154 165 3.1 0.1 3.3 2.8 02/01/2007 21:00:00 7.1 0.5 8 5.7 6.8 0.5 7.6 4.9 6.9 0.5 8.4 5.3 166 11 159 165 3 0 3.3 2.8 02/01/2007 21:10:00 7.1 0.4 8.8 6.5 6.7 0.4 8 5.7 7 0.4 8.4 6.1 169 4 178 165 3.1 0 3.3 2.6 02/01/2007 21:20:00 9.1 1 11.5 7.2 8.7 0.9 10.7 6.8 9.1 1 11.5 7.6 173 4 177 165 3.1 0 3.3 3 02/01/2007 21:30:00 10.7 0.8 12.2 8.8 10.2 0.7 11.8 8 10.6 0.8 12.2 8.4 173 11 156 165 3.2 0 3.5 2.8 02/01/2007 21:40:00 10.5 0.9 13 8.8 10.1 0.8 12.2 8.4 10.6 0.8 12.6 8 177 8 176 165 3.3 0 3.5 3 02/01/2007 21:50:00 8.7 0.8 11.1 6.8 8.5 0.7 10.3 6.5 8.8 0.8 10.7 6.5 179 6 184 165 3.3 0 3.5 3.3 02/01/2007 22:00:00 7.7 1.2 10.7 5.3 7.4 1.1 10.3 5.3 7.8 1 11.1 5.3 172 9 180 165 3.3 0 3.5 3.3 02/01/2007 22:10:00 6.2 0.7 8.4 4.2 6 0.7 7.6 3.8 6.2 0.7 8.4 4.6 161 9 164 165 3.2 0 3.3 3 02/01/2007 22:20:00 5.6 0.7 7.2 4.2 5.5 0.6 7.2 3.8 5.7 0.7 7.2 4.2 162 8 171 165 3.1 0 3.3 3 02/01/2007 22:30:00 6.3 0.9 8.8 4.6 6.1 0.8 8.4 4.6 6.3 0.8 8.4 4.6 169 10 187 165 3.2 0 3.5 3 02/01/2007 22:40:00 7.8 0.8 9.5 6.1 7.5 0.7 9.5 6.1 7.8 0.8 9.9 6.5 163 11 168 165 3 0 3.3 2.8 02/01/2007 22:50:00 8.1 0.8 10.7 6.5 7.8 0.8 9.9 6.1 8 0.8 10.3 6.1 166 7 165 165 3 0 3.3 2.8 02/01/2007 23:00:00 7.4 0.8 9.5 4.6 7.1 0.8 9.1 4.9 7.1 0.8 9.1 5.3 162 6 159 165 2.9 0 3.3 2.8 02/01/2007 23:10:00 7.9 0.8 9.9 5.7 7.6 0.7 9.1 5.7 7.8 0.8 9.5 6.1 161 6 164 165 3 0 3.3 2.8 02/01/2007 23:20:00 7.8 0.8 9.5 6.1 7.5 0.8 9.5 5.7 7.8 0.8 9.9 5.3 159 14 165 165 3 0 3.3 2.8 02/01/2007 23:30:00 8.6 0.7 9.9 6.8 8.3 0.7 9.5 6.5 8.4 0.6 9.5 6.8 159 3 155 165 2.9 0 3.3 2.6 02/01/2007 23:40:00 9.4 0.8 10.7 7.2 9.1 0.8 10.7 6.8 9.3 0.9 11.1 6.8 157 3 156 165 2.9 0 3 2.6 02/01/2007 23:50:00 11.2 0.9 12.6 8.4 10.9 0.9 12.6 8 11.2 1 13 8.4 154 3 151 165 3 0 3.3 2.6 02/02/2007 00:00:00 10.2 0.8 12.2 8 10.1 0.8 11.8 8 10.1 0.8 12.2 8.4 148 5 151 165 2.9 0 3.3 2.6 02/02/2007 00:10:00 12.2 0.8 13.7 9.5 12.1 0.8 13.7 9.1 11.8 0.9 13.7 9.1 142 4 142 165 2.9 0 3 2.6 02/02/2007 00:20:00 12.7 0.7 14.1 10.3 12.7 0.7 14.1 10.3 12.3 0.8 13.7 9.9 141 4 143 165 3 0 3.3 2.6 02/02/2007 00:30:00 13.2 0.7 14.9 10.7 13.2 0.7 14.9 10.7 13 0.9 14.9 10.7 141 4 141 165 3 0 3.3 2.6 02/02/2007 00:40:00 12.8 0.8 14.5 10.3 12.7 0.8 14.5 10.7 12.5 0.8 14.5 10.3 141 4 142 165 3 0 3.3 2.8 02/02/2007 00:50:00 12.8 0.8 14.5 11.1 12.8 0.8 14.5 10.7 12.5 0.8 14.5 10.7 144 4 137 165 3 0 3.3 2.8 02/02/2007 01:00:00 11.9 0.6 13.3 9.9 11.7 0.6 13.3 9.9 11.5 0.6 13 9.5 145 4 136 165 3 0 3.3 2.6 02/02/2007 01:10:00 13.2 0.6 14.9 11.1 13.2 0.6 14.5 10.7 12.9 0.7 14.5 10.7 143 5 150 165 3 0 3.3 2.6 02/02/2007 01:20:00 12.6 0.7 14.1 11.1 12.5 0.7 14.1 10.7 12.3 0.7 14.1 10.7 144 3 145 165 3 0 3.3 2.6 02/02/2007 01:30:00 12.7 0.7 14.5 11.1 12.7 0.7 14.1 10.7 12.4 0.7 14.1 10.3 142 3 145 165 3 0 3.3 2.6 02/02/2007 01:40:00 13.2 0.8 15.3 10.7 13.1 0.7 14.9 10.7 12.9 0.8 14.9 10.7 147 3 150 165 3 0 3.3 2.6 02/02/2007 01:50:00 13 0.8 14.9 10.7 12.8 0.8 14.9 11.1 12.7 0.9 14.9 10.3 145 4 147 165 3 0 3.3 2.6 02/02/2007 02:00:00 12.9 0.6 14.5 11.1 12.7 0.6 14.1 10.7 12.5 0.6 14.1 10.3 148 3 148 165 3 0 3.3 2.6 02/02/2007 02:10:00 12.3 0.6 14.5 10.7 12.2 0.6 13.7 10.3 12 0.6 13.7 9.9 146 4 151 165 2.9 0 3 2.8 02/02/2007 02:20:00 12.8 0.9 14.9 10.7 12.7 0.9 14.5 10.7 12.5 0.8 14.9 10.3 145 4 145 165 3 0 3.3 2.8 02/02/2007 02:30:00 12.3 1.1 14.5 9.9 12.2 1.2 14.5 9.5 12 1.1 14.5 9.5 148 3 143 165 3 0 3.3 2.8 02/02/2007 02:40:00 12.8 1.1 15.3 9.5 12.8 1.1 14.9 9.5 12.6 1.1 15.3 9.9 144 4 148 165 3 0 3.3 2.8 02/02/2007 02:50:00 13.7 0.8 15.6 11.1 13.6 0.8 15.6 11.5 13.3 0.9 15.6 11.1 144 4 147 165 3 0 3.3 2.8 02/02/2007 03:00:00 13.8 0.8 15.6 11.5 13.7 0.8 15.6 11.5 13.5 0.8 15.6 11.8 146 3 147 165 3 0 3.3 2.8 02/02/2007 03:10:00 13.7 0.8 15.3 11.1 13.5 0.8 15.6 11.1 13.4 0.8 15.3 11.1 147 4 151 165 3 0 3.3 2.8 02/02/2007 03:20:00 14.2 0.7 15.6 12.2 14.1 0.7 16.1 11.8 13.9 0.8 15.6 11.5 148 3 147 165 3 0 3.3 2.8 02/02/2007 03:30:00 14.6 0.8 16.4 12.2 14.6 0.8 16.1 12.2 14.3 0.9 16.4 11.8 146 4 149 165 3 0 3.3 2.8 02/02/2007 03:40:00 15.1 0.6 16.4 13 15 0.6 16.4 13 14.8 0.7 16.1 12.6 148 3 146 165 2.9 0 3 2.8 02/02/2007 03:50:00 13.6 0.7 15.6 11.8 13.5 0.7 15.3 11.8 13.4 0.8 15.3 11.8 152 3 153 165 3 0 3.3 2.8 02/02/2007 04:00:00 13.4 0.7 14.9 11.8 13.2 0.7 14.9 11.5 13.1 0.7 14.9 11.5 151 3 153 165 2.9 0 3 2.8 02/02/2007 04:10:00 13.2 0.5 14.5 11.5 13 0.5 14.1 11.5 13.1 0.5 14.5 11.5 152 3 152 165 3 0 3 2.8 02/02/2007 04:20:00 12.4 1 14.1 9.9 12.3 1 14.1 9.9 12.3 1 13.7 9.9 148 4 146 165 2.9 0 3.3 2.8 02/02/2007 04:30:00 14.4 1 16.1 12.2 14.4 1 16.4 12.2 14.1 1 16.1 11.5 145 3 145 165 3 0 3.3 2.6 02/02/2007 04:40:00 14.6 0.8 16.4 12.2 14.5 0.8 16.4 12.6 14.3 0.8 16.1 11.8 144 3 143 165 3 0 3.3 2.6 02/02/2007 04:50:00 15 0.7 17.2 13.3 14.9 0.7 16.8 13.3 14.8 0.7 17.2 13 145 3 148 165 3 0 3.3 2.6 02/02/2007 05:00:00 15.3 0.6 16.8 13.3 15.2 0.6 16.4 13.3 15 0.8 16.8 13 146 3 145 165 3 0 3.3 2.6 02/02/2007 05:10:00 14.5 0.7 16.4 12.2 14.4 0.7 16.4 12.6 14.2 0.8 16.4 11.8 145 3 149 165 3 0 3.3 2.6 02/02/2007 05:20:00 15.5 0.6 16.8 13 15.3 0.6 16.4 13 15.3 0.7 16.8 13 147 3 147 165 2.9 0 3.3 2.6 02/02/2007 05:30:00 14.6 0.7 16.4 12.6 14.4 0.7 16.4 12.6 14.3 0.8 16.8 11.8 149 3 147 165 2.9 0 3.3 2.6 02/02/2007 05:40:00 15.2 0.7 16.8 13.3 14.9 0.7 16.4 13 14.8 0.7 16.4 13 148 3 150 165 2.9 0 3 2.6 02/02/2007 05:50:00 15.5 1 17.2 12.2 15.3 0.9 16.8 12.2 15.4 1.1 17.6 12.6 152 3 151 165 3 0 3.3 2.8 02/02/2007 06:00:00 14.3 1.2 17.6 11.8 14.1 1.2 17.2 11.5 14 1.2 17.6 11.8 151 3 153 165 3 0 3.3 2.8 02/02/2007 06:10:00 15.3 1.1 17.9 12.6 15.1 1 17.6 12.2 15.1 1.1 17.6 12.6 151 3 154 165 3 0 3.3 2.8 02/02/2007 06:20:00 15.7 0.8 17.6 13.3 15.6 0.8 17.2 13.3 15.4 0.8 17.6 13.3 148 3 149 165 3 0 3.3 2.8 02/02/2007 06:30:00 15.3 0.7 17.2 13.3 15.1 0.7 16.8 13 15.1 0.7 17.2 13 148 3 147 165 3 0 3.3 2.6 02/02/2007 06:40:00 15.3 0.7 16.8 13.3 15.2 0.7 16.8 13.3 15 0.7 16.4 13 149 3 152 165 3 0 3.3 2.8 02/02/2007 06:50:00 15 0.7 16.8 12.6 14.8 0.7 16.4 12.2 14.7 0.8 16.8 12.2 151 3 141 165 2.9 0 3.3 2.8 02/02/2007 07:00:00 14.5 0.7 16.4 12.6 14.3 0.7 16.1 12.2 14.2 0.7 16.1 12.2 149 3 152 165 3 0 3.3 2.8 02/02/2007 07:10:00 15.2 0.8 17.2 13 15.1 0.8 16.8 13 14.8 1 17.2 12.2 146 4 150 165 3 0 3 2.8 02/02/2007 07:20:00 15.9 0.7 17.9 13.7 15.7 0.7 17.6 13.7 15.6 0.9 17.6 13.3 148 3 147 165 2.9 0 3.3 2.8 02/02/2007 07:30:00 13.7 0.9 15.6 11.5 13.5 0.9 15.6 11.5 13.4 1 16.1 11.1 150 3 148 165 2.9 0 3 2.8 02/02/2007 07:40:00 12.9 0.9 14.9 10.3 12.7 0.9 14.9 10.7 12.6 0.9 14.9 10.7 147 3 143 165 2.9 0 3 2.6 02/02/2007 07:50:00 11.6 0.6 13.3 9.9 11.5 0.6 13 9.9 11.5 0.6 13.7 9.5 145 4 151 165 2.9 0 3 2.8 02/02/2007 08:00:00 13 1 15.3 10.7 12.9 1 14.9 10.3 12.6 1 14.9 9.9 142 3 147 165 2.9 0 3 2.8 02/02/2007 08:10:00 12.7 0.7 14.9 11.1 12.7 0.7 14.5 11.1 12.5 0.9 14.9 10.3 143 4 145 165 2.9 0 3 2.8 02/02/2007 08:20:00 12.1 0.6 13.3 10.3 12 0.6 13.3 10.3 11.8 0.6 13 9.9 142 3 145 165 2.9 0 3 2.8 02/02/2007 08:30:00 11.8 0.7 13.7 9.9 11.7 0.7 13.7 9.9 11.4 0.8 13.7 9.5 145 4 146 165 2.9 0 3 2.6 02/02/2007 08:40:00 11.8 0.7 13.7 9.9 11.7 0.7 13.3 9.9 11.3 0.7 13.3 9.5 145 4 145 165 2.9 0 3 2.6 02/02/2007 08:50:00 12.5 0.8 14.1 10.3 12.5 0.8 14.1 10.3 11.9 1 13.7 9.1 143 4 140 165 2.9 0 3 2.6 02/02/2007 09:00:00 12.2 0.6 13.7 10.3 12.2 0.6 13.3 10.3 11.8 0.7 13.3 9.1 145 3 149 165 2.8 0 3 2.6 02/02/2007 09:10:00 11.3 1 13.3 9.5 11.2 1 13.3 9.1 10.8 0.9 13 8.8 147 3 148 165 2.8 0 3 2.6 02/02/2007 09:20:00 12.6 1 14.9 10.3 12.5 1 14.5 9.9 12.1 1 14.1 9.5 149 4 150 165 2.8 0 3 2.6 02/02/2007 09:30:00 11.6 1.1 14.5 8.8 11.3 1.2 14.5 8.8 11.6 1.2 15.3 9.1 159 13 153 165 2.8 0 3 2.3 02/02/2007 09:40:00 10.9 0.6 12.6 9.1 10.7 0.7 12.6 8.8 11.1 0.7 12.6 9.1 155 9 149 165 2.7 0 3 2.3 02/02/2007 09:50:00 10.5 0.6 12.2 9.1 10.2 0.6 11.5 8.8 10.6 0.6 12.2 8.8 156 3 151 165 2.8 0 3 2.3 02/02/2007 10:00:00 9.4 0.5 11.1 8.4 9.1 0.5 10.7 8.4 9.4 0.5 10.7 8.4 160 3 164 165 2.7 0 2.8 2.6 02/02/2007 10:10:00 9.6 0.7 11.8 8 9.3 0.7 11.5 7.6 9.5 0.7 11.5 7.6 156 6 153 165 2.6 0 2.8 1.8 02/02/2007 10:20:00 10.3 0.5 11.8 9.1 10.1 0.5 11.5 8.8 10.4 0.5 11.8 9.1 155 2 157 165 2.7 0 2.8 2.3 02/02/2007 10:30:00 12.7 0.9 14.5 10.7 12.5 0.9 14.1 10.7 12.4 0.8 14.1 10.3 151 3 149 165 2.7 0 3 2.6 02/02/2007 10:40:00 14.1 0.8 15.6 11.8 13.9 0.8 15.6 11.5 13.9 1 16.1 11.5 153 3 155 165 2.9 0 3 2.6 02/02/2007 10:50:00 14.1 0.6 15.6 12.2 13.9 0.6 15.3 11.8 14.2 0.7 16.1 12.6 154 3 148 165 2.9 0 3 2.8 02/02/2007 11:00:00 13.7 0.8 15.6 11.8 13.5 0.8 15.6 11.5 13.8 0.7 15.6 11.5 156 4 161 165 2.9 0 3.3 2.8 02/02/2007 11:10:00 11.7 0.8 13.7 9.9 11.4 0.8 13.3 9.5 11.9 0.8 14.1 9.9 158 13 155 165 2.9 0 3 2.6 02/02/2007 11:20:00 10.6 0.7 12.6 9.1 10.4 0.6 12.2 8.8 10.4 0.7 12.2 8.4 156 10 159 165 2.9 0 3.3 2.8 02/02/2007 11:30:00 10.3 0.6 11.8 8.4 10.4 0.6 12.2 8.4 10.2 0.6 12.2 8.4 152 4 151 165 3 0 3.3 2.8 02/02/2007 11:40:00 11.9 0.8 13.7 9.9 11.8 0.8 13.7 9.9 11.4 0.8 13.7 8.8 148 3 150 165 2.9 0 3.3 2.8 02/02/2007 11:50:00 12.6 0.8 14.5 11.1 12.4 0.7 14.5 10.7 12.4 0.8 14.5 10.3 151 4 148 165 2.9 0 3 2.8 02/02/2007 12:00:00 11.7 0.6 13.3 9.5 11.5 0.6 13 9.1 11.4 0.6 13.3 9.9 152 3 151 165 2.8 0 3 2.6 02/02/2007 12:10:00 11.8 0.8 13.7 10.3 11.5 0.8 13.7 9.9 11.7 0.8 13.7 10.3 152 3 155 165 2.8 0 3 2.6 02/02/2007 12:20:00 11.6 0.8 13.7 9.5 11.4 0.8 13.3 9.5 11.6 0.8 13.7 9.1 154 4 150 165 2.9 0 3 2.8 02/02/2007 12:30:00 12.1 0.8 14.1 10.3 11.9 0.8 13.7 10.3 12 0.9 14.1 9.9 154 4 156 165 2.9 0 3 2.6 02/02/2007 12:40:00 12.2 0.8 13.7 10.3 11.9 0.8 13.7 10.3 12.3 0.8 14.5 10.3 154 9 164 165 2.9 0 3 2.8 02/02/2007 12:50:00 12.5 1 14.5 9.9 12.2 1 14.1 9.9 12.5 0.9 14.5 9.5 156 5 148 165 2.9 0 3 2.8 02/02/2007 13:00:00 12.3 0.7 13.7 9.9 12 0.7 14.1 9.5 12.6 0.6 14.1 10.7 156 6 162 165 2.9 0 3.3 2.8 02/02/2007 13:10:00 11.7 0.6 13.3 9.9 11.5 0.6 13.3 9.5 12 0.6 13.7 10.3 156 3 152 165 2.9 0 3.3 2.8 02/02/2007 13:20:00 11.4 0.6 13 10.3 11.2 0.6 12.6 9.9 11.7 0.7 13.3 10.3 155 4 154 165 2.9 0 3.3 2.8 02/02/2007 13:30:00 11.7 0.5 12.6 10.3 11.4 0.4 13 10.3 11.9 0.5 13.3 10.3 155 3 153 165 2.9 0 3 2.6 02/02/2007 13:40:00 12.3 0.8 14.5 9.9 12 0.8 14.1 10.3 12.1 0.8 14.5 9.9 152 3 153 165 2.8 0 3 2.6 02/02/2007 13:50:00 12.8 0.7 14.5 10.3 12.6 0.7 14.1 10.3 12.2 0.8 13.7 9.9 151 3 156 165 2.7 0 2.8 2.6 02/02/2007 14:00:00 13.5 0.7 15.3 11.1 13.3 0.7 14.9 10.7 13.5 0.8 15.3 11.1 152 3 155 165 2.9 0 3 2.6 02/02/2007 14:10:00 12.6 0.8 14.9 10.7 12.4 0.8 14.5 10.3 12.7 0.8 15.3 10.7 155 5 157 165 3 0 3.3 2.8 02/02/2007 14:20:00 11.4 0.8 13 8.8 11.1 0.8 13 8.8 11.7 0.8 14.1 8.8 156 4 157 165 3 0 3.3 2.8 02/02/2007 14:30:00 10.6 0.6 12.2 9.1 10.4 0.6 11.8 8.8 10.8 0.6 12.2 8.8 154 4 157 165 3.1 0.1 3.5 2.8 02/02/2007 14:40:00 11.6 0.7 13 9.9 11.3 0.8 13 9.5 11.8 0.8 13.3 9.1 154 4 152 165 2.9 0 3.3 2.3 02/02/2007 14:50:00 12.7 0.7 14.5 10.3 12.4 0.7 14.1 10.3 12.8 0.7 14.9 10.7 152 4 153 165 2.8 0 3 2.6 02/02/2007 15:00:00 12.8 0.6 14.5 10.7 12.4 0.6 14.1 10.7 12.7 0.7 14.5 9.9 154 9 161 165 2.7 0 3 2.6 02/02/2007 15:10:00 11 0.8 13 8.8 10.7 0.8 13 8.8 10.7 0.9 13 8.8 152 3 155 165 2.8 0 3 2.6 02/02/2007 15:20:00 8.9 1 10.7 6.5 8.6 0.9 10.7 6.5 8.7 1 11.1 6.5 152 3 154 165 3 0 3.3 2.8 02/02/2007 15:30:00 8.1 0.5 9.1 6.5 7.9 0.5 8.8 6.5 7.9 0.6 9.5 6.1 154 3 157 165 2.9 0 3.3 2.3 02/02/2007 15:40:00 8.8 0.4 9.9 7.6 8.5 0.4 9.5 7.6 8.5 0.5 9.9 7.2 155 3 161 165 2.7 0 3 2.3 02/02/2007 15:50:00 8.3 0.8 10.7 6.5 8 0.8 9.9 6.1 8.1 0.8 10.7 6.1 156 8 157 165 2.6 0 2.8 2.3 02/02/2007 16:00:00 6.9 0.6 8.4 5.3 6.6 0.6 8 4.9 7 0.6 8.4 5.3 160 12 144 165 2.7 0 2.8 2.3 02/02/2007 16:10:00 6 0.7 7.2 4.2 5.8 0.6 6.8 4.2 6 0.6 7.2 4.2 162 14 162 165 2.8 0 3 2.6 02/02/2007 16:20:00 6.6 0.6 8.4 4.9 6.3 0.6 8 4.9 6.6 0.6 8.4 5.3 167 12 183 165 2.9 0 3 2.6 02/02/2007 16:30:00 6.5 0.8 8.4 4.9 6.2 0.7 7.6 4.6 6.2 0.7 8.4 4.6 171 13 167 165 2.8 0 3 2.6 02/02/2007 16:40:00 6.6 0.7 8.4 4.9 6.3 0.7 8 4.9 6.4 0.7 8 4.6 167 5 167 165 2.7 0 2.8 2.3 02/02/2007 16:50:00 6.5 0.9 9.1 4.6 6.3 0.8 8.8 4.6 6.2 0.9 8.8 4.2 168 12 165 165 2.7 0 2.8 2.6 02/02/2007 17:00:00 6.6 0.8 8.4 4.2 6.4 0.7 8 4.2 6.3 0.7 8.4 4.2 166 12 165 165 2.7 0 2.8 2.6 02/02/2007 17:10:00 6 0.9 8 3.8 5.7 0.8 7.6 3.4 5.7 0.8 7.6 3.8 164 8 165 165 2.6 0 2.8 2.3 02/02/2007 17:20:00 5.3 0.6 7.2 3.8 5.2 0.6 7.2 3.8 5.3 0.6 6.8 3.8 164 9 163 165 2.7 0 3 2.6 02/02/2007 17:30:00 4.6 1.2 8.8 2.6 4.6 1.1 8.4 2.6 4.8 1.3 8.8 3 170 13 180 165 2.7 0 3 2.6 02/02/2007 17:40:00 4.9 1 7.6 2.3 4.7 1 7.2 2.3 5 1 8 2.6 174 12 181 165 2.7 0 3 2.6 02/02/2007 17:50:00 5.7 0.8 8 3.8 5.5 0.8 7.6 3.4 5.7 0.8 7.6 4.2 167 12 172 165 2.7 0 3 2.6 02/02/2007 18:00:00 5.5 0.8 7.2 3.8 5.3 0.6 6.8 3.8 5.7 0.7 7.2 4.2 169 14 179 165 2.6 0 2.8 2.3 02/02/2007 18:10:00 7.6 0.8 10.3 6.1 7.3 0.8 9.9 5.7 7.5 0.7 9.5 5.7 171 8 181 165 2.5 0 2.8 2.3 02/02/2007 18:20:00 7.8 0.5 9.5 6.1 7.4 0.5 8.8 6.5 7.7 0.5 9.5 6.1 171 5 169 165 2.6 0 2.8 2.3 02/02/2007 18:30:00 5.9 1.1 8.4 4.2 5.6 1.1 8 4.2 5.9 1.1 8.8 4.2 167 6 175 165 2.5 0 2.8 2.3 02/02/2007 18:40:00 4 1 5.7 1.9 3.8 1 5.7 1.5 4 1.1 6.1 1.5 167 11 165 165 2.5 0 2.8 2.3 02/02/2007 18:50:00 3.1 0.8 5.7 1.5 2.9 0.8 5.3 1.1 3 1 5.3 0.4 142 21 145 165 2.5 0 2.8 2.3 02/02/2007 19:00:00 3.8 1.5 6.8 0.4 3.7 1.5 6.8 0.4 3.5 1.5 6.5 0.4 138 17 143 165 2.5 0.1 2.8 1.8 02/02/2007 19:10:00 3.5 1.2 5.7 0.4 3.5 1.3 6.1 0.4 3.4 1.2 5.7 0.4 129 13 113 165 2.5 0.1 2.8 1.8 02/02/2007 19:20:00 3.7 0.7 4.9 1.9 3.5 0.7 4.9 1.5 3.3 1 4.9 0.4 130 11 122 165 2.5 0.1 2.8 1.8 02/02/2007 19:30:00 2.7 0.7 4.2 0.7 2.5 0.7 4.2 0.4 2.2 0.7 3.8 0.7 129 11 146 165 2.5 0.1 2.8 1.8 02/02/2007 19:40:00 3 0.7 4.6 0.7 2.8 0.8 4.2 0.4 2.8 1 4.6 0.4 133 13 130 165 2.6 0 2.8 2.1 02/02/2007 19:50:00 3.7 0.5 4.6 2.3 3.5 0.5 4.6 2.3 3.5 0.5 4.6 1.9 128 8 140 165 2.6 0 2.8 2.1 02/02/2007 20:00:00 3.9 0.6 5.3 1.9 3.8 0.6 5.3 1.5 3.5 0.7 4.9 1.9 133 7 123 165 2.5 0 2.8 2.1 02/02/2007 20:10:00 3.7 0.6 4.9 2.3 3.5 0.6 4.9 1.5 3.3 0.7 4.9 1.1 129 9 135 165 2.5 0 2.8 2.3 02/02/2007 20:20:00 4.4 0.5 5.7 3 4.3 0.5 5.3 3 4.1 0.5 5.3 2.6 127 7 124 165 2.6 0 2.8 2.6 02/02/2007 20:30:00 4.5 0.5 5.7 2.6 4.4 0.6 5.7 2.3 4.3 0.5 5.3 2.6 134 8 126 165 2.7 0 2.8 2.6 02/02/2007 20:40:00 5 0.4 6.1 3.4 4.8 0.4 6.1 3.4 4.9 0.5 6.1 3.4 145 5 138 165 2.6 0 2.8 2.6 02/02/2007 20:50:00 5.4 0.6 6.8 3.8 5.1 0.6 6.5 3.8 5.3 0.7 6.5 3.8 152 4 146 165 2.6 0 2.8 2.6 02/02/2007 21:00:00 5.3 0.4 6.1 4.2 5 0.4 6.1 3.8 5.3 0.4 6.1 4.2 147 4 148 165 2.5 0 2.8 2.3 02/02/2007 21:10:00 6.8 0.5 8 5.3 6.6 0.5 7.6 5.3 6.6 0.5 7.6 4.9 141 4 144 165 2.5 0 2.8 2.3 02/02/2007 21:20:00 6.6 0.6 8.4 4.9 6.5 0.6 8 4.9 6.5 0.6 8 4.9 144 3 143 165 2.5 0 2.8 2.3 02/02/2007 21:30:00 6.5 0.5 7.6 5.3 6.4 0.4 7.2 5.3 6.4 0.4 7.6 4.6 145 5 144 165 2.5 0 2.8 2.3 02/02/2007 21:40:00 7 0.6 8.4 5.3 6.8 0.6 8 5.3 6.8 0.7 8 4.6 144 5 146 165 2.5 0 2.8 2.3 02/02/2007 21:50:00 7.5 0.7 9.5 5.7 7.4 0.7 9.1 5.7 7.2 0.7 8.8 4.9 143 6 139 165 2.4 0 2.6 2.3 02/02/2007 22:00:00 9.2 0.9 11.1 6.5 9 0.9 10.7 6.5 8.8 1 10.7 5.7 143 6 143 165 2.4 0 2.6 2.3 02/02/2007 22:10:00 9.9 0.5 11.1 8.4 9.7 0.5 10.7 8 9.5 0.6 10.7 7.6 146 3 145 165 2.4 0 2.6 2.3 02/02/2007 22:20:00 9.2 1 11.1 6.8 9 1 10.7 6.8 8.8 1 11.1 6.1 147 4 155 165 2.4 0 2.6 2.3 02/02/2007 22:30:00 8.9 1 11.1 6.5 8.8 1 10.7 6.8 8.5 1 10.7 5.7 141 6 145 165 2.4 0 2.6 2.3 02/02/2007 22:40:00 9.5 0.5 10.7 8.4 9.4 0.5 10.7 8 9.2 0.6 10.7 7.6 144 4 136 165 2.4 0 2.6 1.8 02/02/2007 22:50:00 9.6 0.5 10.7 8 9.4 0.5 10.3 8 9.3 0.6 10.7 7.2 148 3 145 165 2.3 0 2.6 2.1 02/02/2007 23:00:00 9.2 0.5 10.3 7.6 9 0.5 10.3 7.6 8.9 0.6 10.3 7.6 150 3 145 165 2.2 0 2.3 2.1 02/02/2007 23:10:00 9 0.4 10.7 8 8.8 0.4 10.3 7.6 8.8 0.5 10.7 7.2 152 3 147 165 2.2 0 2.3 2.1 02/02/2007 23:20:00 9.2 0.5 10.7 8 8.9 0.5 10.3 7.6 9 0.6 10.7 7.6 151 3 146 165 2.2 0 2.3 2.1 02/02/2007 23:30:00 8.8 0.5 9.9 7.2 8.5 0.5 9.5 6.8 8.5 0.5 9.9 6.8 153 4 158 165 2.2 0 2.3 2.1 02/02/2007 23:40:00 8.7 0.5 10.3 7.2 8.4 0.5 10.3 6.8 8.5 0.5 9.9 7.2 152 4 145 165 2.2 0 2.3 2.1 02/02/2007 23:50:00 7.9 0.5 9.1 6.5 7.7 0.5 8.8 6.5 7.6 0.7 9.1 5.3 150 3 148 165 2.2 0 2.3 2.1 02/03/2007 00:00:00 5.9 0.6 7.2 4.6 5.8 0.5 7.2 4.6 5.4 0.7 7.2 3.4 143 5 153 165 2.2 0 2.6 2.1 02/03/2007 00:10:00 6.1 0.5 7.2 4.2 6 0.5 6.8 4.2 5.6 0.5 6.8 3.8 141 5 137 165 2.2 0 2.3 1.6 02/03/2007 00:20:00 6.3 0.6 7.6 4.6 6.1 0.6 7.6 4.6 5.9 0.7 7.2 4.2 140 5 130 165 2.2 0 2.3 2.1 02/03/2007 00:30:00 5.8 0.5 6.8 4.2 5.7 0.5 6.5 4.2 5.3 0.6 6.5 3 137 5 141 165 2.1 0 2.3 2.1 02/03/2007 00:40:00 5.4 0.5 6.5 3.8 5.3 0.5 6.1 4.2 5.1 0.5 6.5 2.6 138 6 146 165 2.1 0 2.3 1.8 02/03/2007 00:50:00 5.2 0.5 6.8 3.8 5 0.5 6.5 3.4 4.9 0.6 6.8 3.4 145 5 150 165 2.1 0 2.3 2.1 02/03/2007 01:00:00 5.4 0.4 6.5 4.6 5.1 0.4 6.1 4.2 5.2 0.4 6.1 4.2 146 4 145 165 2.1 0 2.3 2.1 02/03/2007 01:10:00 5.1 0.5 6.1 3.8 5 0.4 5.7 3.8 5 0.5 6.1 4.2 141 4 141 165 2.1 0 2.3 1.8 02/03/2007 01:20:00 5.5 0.4 6.5 3.8 5.4 0.4 6.1 4.6 5.2 0.5 6.1 3.4 137 4 139 165 2.1 0 2.3 1.8 02/03/2007 01:30:00 4.4 0.4 6.1 3.4 4.3 0.4 5.7 3.4 4 0.5 4.9 2.6 132 5 141 165 2.1 0 2.3 1.8 02/03/2007 01:40:00 4.1 0.4 4.9 3 4 0.4 4.9 3 3.8 0.4 4.9 2.6 135 4 136 165 2.1 0 2.3 1.8 02/03/2007 01:50:00 4.9 0.5 6.1 3 4.9 0.6 6.1 3 4.6 0.5 5.7 3 133 5 130 165 2.1 0 2.3 1.8 02/03/2007 02:00:00 3.9 1 6.1 2.3 3.8 0.9 5.7 2.3 3.6 1 5.3 0.7 123 7 126 165 2.1 0 2.3 1.8 02/03/2007 02:10:00 2.9 0.4 4.2 2.3 2.8 0.4 4.2 2.3 2.6 0.4 3.8 1.9 126 7 126 165 2.1 0 2.3 1.8 02/03/2007 02:20:00 3.5 0.4 4.2 2.6 3.4 0.4 4.2 2.3 3.3 0.5 4.6 1.9 138 6 148 165 2 0 2.3 1.8 02/03/2007 02:30:00 3.9 0.5 4.9 2.3 3.8 0.5 4.6 1.9 3.8 0.5 4.6 2.3 140 6 143 165 2 0 2.3 1.8 02/03/2007 02:40:00 3 0.5 4.2 1.9 2.8 0.5 3.8 1.5 2.5 0.6 3.8 0.7 135 6 137 165 2 0 2.3 1.8 02/03/2007 02:50:00 2.9 0.8 4.6 1.5 2.7 0.8 4.2 1.5 2.7 0.7 4.2 1.5 143 5 151 165 2 0 2.3 1.8 02/03/2007 03:00:00 5.7 0.6 6.5 3.8 5.5 0.6 6.5 3.8 5.6 0.7 6.5 3.4 148 4 150 165 2 0 2.3 1.8 02/03/2007 03:10:00 5.7 0.4 6.5 4.6 5.5 0.4 6.5 4.6 5.5 0.4 6.5 4.6 144 3 149 165 2 0 2.3 1.8 02/03/2007 03:20:00 5.7 0.5 6.8 4.6 5.5 0.5 6.8 4.6 5.5 0.4 6.5 4.6 139 4 135 165 2 0 2.3 1.8 02/03/2007 03:30:00 5.4 0.6 6.5 3.8 5.5 0.5 6.5 3.8 5.5 0.6 6.5 3.8 142 5 129 165 1.9 0 2.3 1.8 02/03/2007 03:40:00 6.7 0.7 8 5.3 6.6 0.6 7.6 5.3 6.7 0.6 8 5.3 147 5 145 165 1.9 0 2.3 1.8 02/03/2007 03:50:00 4.3 1.2 6.5 1.9 4.1 1.2 6.5 1.9 4.1 1 6.5 1.9 146 8 156 165 1.9 0 2.1 1.8 02/03/2007 04:00:00 3.5 0.4 4.2 2.3 3.3 0.3 4.2 2.3 3.3 0.4 4.2 2.3 147 4 148 165 1.9 0 2.1 1.8 02/03/2007 04:10:00 4 0.2 4.6 3.4 3.8 0.3 4.6 3.4 3.9 0.3 4.6 3 151 4 141 165 1.8 0 1.8 1.6 02/03/2007 04:20:00 4.1 0.5 5.3 3 3.9 0.4 4.9 3 4 0.4 4.9 3 151 3 150 165 1.8 0 1.8 1.6 02/03/2007 04:30:00 4 0.4 4.9 3.4 3.8 0.4 4.6 3 3.9 0.5 4.9 2.6 155 3 156 165 1.8 0 1.8 1.6 02/03/2007 04:40:00 4.3 0.6 5.3 2.6 4.1 0.5 4.9 2.6 4.2 0.6 5.3 2.6 156 3 164 165 1.7 0 1.8 1.6 02/03/2007 04:50:00 2.7 0.6 4.2 1.5 2.5 0.6 3.8 1.1 2.6 0.6 4.2 1.1 165 5 165 165 1.7 0 1.8 1.4 02/03/2007 05:00:00 3.7 0.8 5.7 1.5 3.4 0.8 5.3 1.5 3.7 0.8 5.7 1.9 168 7 165 165 1.7 0 1.8 1.6 02/03/2007 05:10:00 3.7 0.3 4.6 3 3.6 0.3 4.6 2.6 3.8 0.4 4.9 3 175 7 171 165 1.5 0 1.8 1.4 02/03/2007 05:20:00 3.6 0.3 4.2 2.6 3.4 0.4 4.2 2.6 3.6 0.4 4.6 2.6 174 5 170 165 1.4 0.2 1.6 0.9 02/03/2007 05:30:00 1.9 0.6 3.4 0.4 1.4 0.7 2.6 0.4 1.7 0.6 3 0.4 173 17 179 165 1.3 0.2 1.6 0.7 02/03/2007 05:40:00 1 0.7 2.3 0.4 0.7 0.5 2.3 0.4 0.8 0.6 2.3 0.4 157 10 154 165 1.4 0.2 1.6 0.9 02/03/2007 05:50:00 2 0.5 3 0.7 1.7 0.5 2.6 0.4 1.8 0.5 2.6 0.4 161 15 146 165 1.4 0.2 1.8 0.9 02/03/2007 06:00:00 0.9 0.4 1.9 0.4 0.5 0.3 1.9 0.4 0.6 0.3 1.5 0.4 200 21 205 165 1.5 0.1 1.8 0.9 02/03/2007 06:10:00 1.6 0.5 3 0.4 1.1 0.6 2.6 0.4 1.2 0.5 2.6 0.4 150 13 156 165 1.3 0.2 1.8 0.7 02/03/2007 06:20:00 1.3 0.4 2.3 0.4 0.8 0.4 1.9 0.4 0.6 0.4 1.9 0.4 138 5 135 165 1.3 0.2 1.6 0.7 02/03/2007 06:30:00 1.7 0.3 2.3 1.1 0.4 0 0.4 0.4 1.6 0.4 2.3 0.4 137 1 137 165 1.2 0.2 1.6 0.7 02/03/2007 06:40:00 2.1 0.3 2.6 1.5 0.4 0 0.4 0.4 1.8 0.3 2.6 1.1 138 0 137 165 1.1 0.1 1.4 0.7 02/03/2007 06:50:00 2.3 0.2 2.6 1.5 0.4 0 0.4 0.4 1.8 0.3 2.3 0.7 138 0 138 165 1.1 0 1.4 0.7 02/03/2007 07:00:00 1.5 0.7 3 0.4 0.4 0 0.4 0.4 0.9 0.5 2.3 0.4 138 0 138 165 1.1 0 1.4 0.4 02/03/2007 07:10:00 2.5 0.6 3.4 1.1 0.4 0 0.4 0.4 1.9 0.6 3 0.4 138 0 138 165 1.2 0.1 1.4 0.7 02/03/2007 07:20:00 0.7 0.4 1.5 0.4 0.4 0 0.4 0.4 0.4 0.1 1.1 0.4 138 0 137 165 1 0.2 1.4 0.4 02/03/2007 07:30:00 2.9 1 4.2 0.7 0.4 0 0.4 0.4 2.7 1.2 4.2 0.4 138 0 137 165 0.9 0.2 1.4 -0.1 02/03/2007 07:40:00 2.9 0.6 4.2 1.9 0.4 0 0.4 0.4 2.9 0.6 3.8 1.5 138 0 137 165 0.8 0.1 0.9 0.2 02/03/2007 07:50:00 2.2 0.2 2.6 1.9 0.4 0 0.4 0.4 1.8 0.2 2.3 1.1 138 0 137 165 0.8 0 1.1 0.7 02/03/2007 08:00:00 1.3 0.5 2.3 0.7 0.4 0 0.4 0.4 0.8 0.6 2.3 0.4 138 0 137 165 0.9 0 1.4 0.9 02/03/2007 08:10:00 1.2 0.3 1.9 0.7 0.4 0 0.4 0.4 0.5 0.3 1.5 0.4 138 0 137 165 0.9 0 1.1 0.9 02/03/2007 08:20:00 1.4 0.4 2.3 0.7 0.4 0 0.4 0.4 0.7 0.6 2.3 0.4 138 0 138 165 0.8 0 1.1 0.7 02/03/2007 08:30:00 1.5 0.5 2.6 0.4 0.4 0 0.4 0.4 1 0.7 2.3 0.4 138 0 137 165 0.8 0 0.9 0.7 02/03/2007 08:40:00 0.8 0.4 1.5 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 138 0 138 165 0.7 0 0.9 0.4 02/03/2007 08:50:00 0.5 0.3 1.5 0.4 0.4 0 0.4 0.4 0.4 0.1 1.1 0.4 138 0 137 165 0.7 0 0.9 0.4 02/03/2007 09:00:00 0.4 0.2 1.1 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 138 0 137 165 0.4 0.1 0.9 0.2 02/03/2007 09:10:00 0.9 0.6 2.3 0.4 0.4 0 0.4 0.4 0.6 0.4 1.9 0.4 138 0 138 165 0.4 0.1 0.9 0.2 02/03/2007 09:20:00 1.3 0.3 2.3 0.7 0.4 0 0.4 0.4 1 0.4 2.3 0.4 138 0 138 165 0.1 0 0.7 -0.1 02/03/2007 09:30:00 1.4 0.6 2.6 0.4 0.4 0 0.4 0.4 0.9 0.6 2.3 0.4 138 0 138 165 0.2 0 0.7 -0.1 02/03/2007 09:40:00 1.3 0.5 2.6 0.4 0.4 0 0.4 0.4 0.5 0.3 1.5 0.4 138 0 138 165 0.3 0.1 0.7 0.2 02/03/2007 09:50:00 0.4 0.1 1.5 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 138 0 138 165 0.2 0 0.4 -0.1 02/03/2007 10:00:00 0.5 0.3 1.5 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 137 1 137 165 0.7 0.3 1.1 -0.3 02/03/2007 10:10:00 1 0.6 2.3 0.4 0.4 0 0.4 0.4 0.8 0.6 2.3 0.4 137 1 137 165 0.5 0.1 0.9 -0.1 02/03/2007 10:20:00 2.9 0.4 3.8 2.3 0.4 0 0.4 0.4 2.8 0.5 3.8 1.5 137 0 138 165 0.5 0.2 0.9 -0.3 02/03/2007 10:30:00 1.9 0.8 3.4 0.4 0.4 0 0.4 0.4 1.7 0.9 3.4 0.4 138 0 137 165 0.7 0 0.9 0.2 02/03/2007 10:40:00 0.5 0.3 1.9 0.4 0.4 0 0.4 0.4 0.4 0.1 1.1 0.4 137 0 137 165 0.8 0.1 1.1 0.2 02/03/2007 10:50:00 0.7 0.5 1.9 0.4 0.4 0 0.7 0.4 0.4 0.2 1.5 0.4 137 1 138 165 0.7 0.1 1.1 0.2 02/03/2007 11:00:00 1.2 0.5 2.3 0.4 0.4 0 0.4 0.4 0.9 0.5 2.3 0.4 137 0 137 165 0.9 0.2 1.4 0.2 02/03/2007 11:10:00 1.7 0.5 3.4 0.7 0.4 0 0.4 0.4 1.1 0.6 3 0.4 137 1 135 165 0.9 0.4 1.6 0.2 02/03/2007 11:20:00 1.8 0.5 3.4 0.7 0.4 0 0.4 0.4 1.4 0.5 3 0.4 136 1 137 165 1.2 0.1 1.6 0.7 02/03/2007 11:30:00 1.7 0.5 2.6 0.4 0.4 0 0.4 0.4 1.3 0.5 2.6 0.4 135 2 136 165 1.1 0 1.4 0.9 02/03/2007 11:40:00 2.1 0.4 3 1.1 0.4 0 0.4 0.4 1.9 0.4 2.6 0.7 121 4 128 165 1.1 0 1.6 0.7 02/03/2007 11:50:00 1.2 0.6 2.6 0.4 0.4 0 0.4 0.4 1.1 0.5 2.3 0.4 118 1 118 165 1 0 1.4 0.9 02/03/2007 12:00:00 1.3 0.5 2.6 0.4 0.4 0 0.4 0.4 1 0.4 2.3 0.4 103 13 116 165 1.2 0.2 1.6 0.9 02/03/2007 12:10:00 1.2 0.5 2.3 0.4 0.4 0 0.4 0.4 0.7 0.3 1.9 0.4 303 28 284 165 1.4 0.1 1.6 1.4 02/03/2007 12:20:00 1.7 0.5 3 0.4 1 0.7 2.6 0.4 1.3 0.7 2.6 0.4 288 8 284 165 1.2 0 1.4 0.9 02/03/2007 12:30:00 2.2 0.5 3.8 1.1 2.2 0.6 3.4 0.7 2.1 0.5 3.4 0.7 277 12 285 165 1 0.1 1.6 0.9 02/03/2007 12:40:00 2.7 0.5 3.4 1.9 2.5 0.5 3.4 1.5 1.9 0.5 3.4 0.7 294 10 289 165 1.2 0.2 1.8 0.9 02/03/2007 12:50:00 2.2 0.4 3 1.1 2.3 0.3 3 1.5 2.2 0.3 2.6 1.5 271 5 274 165 1.5 0 1.8 1.4 02/03/2007 13:00:00 1.2 0.9 3.4 0.4 1.2 1 3.4 0.4 1 1 3 0.4 242 38 277 165 2.1 0.2 2.6 1.6 02/03/2007 13:10:00 0.4 0.1 1.1 0.4 0.4 0 0.4 0.4 0.4 0.1 1.5 0.4 13 56 199 165 2.7 0.2 3 1.8 02/03/2007 13:20:00 0.6 0.4 1.9 0.4 0.4 0.2 1.5 0.4 0.7 0.4 1.9 0.4 95 79 166 165 2 0 2.3 1.8 02/03/2007 13:30:00 2.5 0.6 3.4 0.4 1.7 0.6 3 0.4 2.6 0.7 3.8 1.1 352 11 354 165 2.1 0.1 2.8 1.8 02/03/2007 13:40:00 2.9 0.6 4.6 1.9 2.7 0.7 4.6 1.5 2.7 0.4 4.2 1.9 317 19 292 165 1.9 0.1 2.3 1.6 02/03/2007 13:50:00 3.7 0.5 4.6 2.3 3.6 0.4 4.6 2.6 3.1 0.5 4.2 1.5 280 6 286 165 1.6 0 1.8 1.4 02/03/2007 14:00:00 3.5 1 5.3 1.1 3.6 0.9 5.3 1.1 3.2 0.8 4.9 1.1 276 13 279 165 2.4 0.2 3.3 1.8 02/03/2007 14:10:00 3.2 0.6 4.9 1.9 3.2 0.6 4.9 1.9 2.9 0.7 4.6 1.1 280 12 287 165 2.7 0.1 3.3 2.3 02/03/2007 14:20:00 2.7 0.5 3.8 0.7 2.6 0.6 3.8 0.7 2.7 0.7 4.2 1.1 289 10 289 165 2.3 0 2.8 2.1 02/03/2007 14:30:00 2.1 0.7 3.8 0.7 1.7 0.8 3.4 0.4 2 0.6 3.8 0.4 313 16 312 165 2.4 0.2 3 2.1 02/03/2007 14:40:00 2.9 0.8 4.6 1.1 2.9 0.8 4.6 0.7 3.2 0.7 4.6 0.7 284 9 296 165 2.6 0.2 3.3 2.1 02/03/2007 14:50:00 3.4 0.5 4.6 1.5 3.3 0.6 4.6 1.1 3.7 0.6 4.9 1.5 287 9 284 165 2.2 0 2.3 2.1 02/03/2007 15:00:00 4.5 0.8 6.8 2.6 4.5 0.9 6.8 2.6 4.4 1 6.5 1.9 283 9 293 165 2.3 0 2.8 2.1 02/03/2007 15:10:00 5.3 1 8 3 5.3 1 7.6 2.6 5.1 0.9 7.6 2.6 287 9 302 165 2.3 0 2.6 2.1 02/03/2007 15:20:00 4.5 1 7.2 2.3 4.5 1 6.8 1.9 4.5 0.8 6.8 2.3 287 12 290 165 2.3 0 2.8 2.1 02/03/2007 15:30:00 3.8 1.5 6.8 1.1 3.8 1.5 6.8 0.4 4 1.6 7.6 1.1 281 12 280 165 2.5 0.1 2.8 2.1 02/03/2007 15:40:00 5.1 1.3 8 1.5 5.3 1.3 8.4 1.5 5.5 1.3 8.4 2.6 279 9 284 165 2.1 0.1 2.6 1.8 02/03/2007 15:50:00 3.9 1 5.7 0.4 4 1.1 6.1 0.7 3.9 1.1 6.1 0.7 282 15 270 165 2.3 0 2.8 2.1 02/03/2007 16:00:00 2.8 0.7 4.6 0.7 2.6 0.9 4.6 0.4 2.7 0.8 4.9 0.7 306 20 282 165 2.6 0.1 3 2.3 02/03/2007 16:10:00 4.6 0.9 6.5 2.3 4.6 0.9 6.5 1.9 4.3 0.9 6.8 2.3 290 10 302 165 2.2 0.2 2.8 1.8 02/03/2007 16:20:00 6.1 1 9.5 3.8 6.2 1 9.1 3.8 5.7 1 9.9 3 287 9 284 165 2 0.1 2.6 1.8 02/03/2007 16:30:00 5.2 0.6 6.5 3.4 5.3 0.6 6.8 3.8 4.9 0.8 7.2 3.4 289 8 306 165 1.8 0 1.8 1.6 02/03/2007 16:40:00 2.4 1 6.5 0.4 2.7 0.9 6.5 0.7 2.6 1.1 6.5 0.7 305 23 290 165 2 0.2 2.3 1.6 02/03/2007 16:50:00 2.1 0.8 4.2 0.4 1.9 0.8 3.8 0.4 1.9 0.8 3.4 0.4 335 18 325 165 2.6 0.1 3 2.1 02/03/2007 17:00:00 3 1 4.6 0.4 3.1 1 4.6 0.4 3.1 1 4.9 0.7 284 13 281 165 2.1 0.4 3.3 1.6 02/03/2007 17:10:00 3.8 1 6.1 1.5 3.9 1 6.1 1.5 4 0.9 6.1 1.1 282 8 278 165 1.7 0 1.8 1.6 02/03/2007 17:20:00 4.4 0.6 6.1 2.3 4.4 0.6 6.1 2.3 4.1 0.8 6.1 1.5 287 10 300 165 1.5 0.1 2.1 1.4 02/03/2007 17:30:00 2 1.3 5.3 0.4 2.3 1.2 5.3 0.4 2.3 1.2 5.3 0.4 287 20 277 165 1.8 0.2 2.3 1.4 02/03/2007 17:40:00 4 0.8 5.7 1.5 4.2 0.8 6.1 1.9 3.8 0.9 5.7 1.5 289 9 287 165 1.7 0 1.8 1.6 02/03/2007 17:50:00 4.5 0.8 6.5 2.3 4.7 0.8 6.5 2.3 3.7 1 6.1 1.1 291 8 296 165 1.4 0.1 1.8 1.4 02/03/2007 18:00:00 4 0.6 5.3 3 4.2 0.6 5.7 3 3.6 0.6 5.7 1.9 287 6 294 165 1.4 0 1.8 1.4 02/03/2007 18:10:00 5.7 0.9 7.6 3 5.9 0.9 7.2 3.4 5.3 0.9 6.8 1.9 287 6 293 165 1.6 0.1 1.8 1.4 02/03/2007 18:20:00 6.3 0.8 8.8 3.8 6.4 0.8 8.4 4.2 4.9 0.9 7.2 2.3 292 5 291 165 1.3 0.1 1.8 1.1 02/03/2007 18:30:00 7 0.8 8.4 4.6 7 0.9 8.8 4.9 5.6 1.1 8 3.4 298 8 291 165 1.7 0 2.1 1.4 02/03/2007 18:40:00 4.9 0.6 6.8 3 4.9 0.7 6.8 2.3 4.3 0.6 5.7 2.3 314 6 311 165 1.8 0 2.1 1.6 02/03/2007 18:50:00 4.6 0.9 6.1 2.6 4.4 0.9 6.5 2.6 3.6 0.8 5.7 1.9 307 6 312 165 2.1 0.1 2.6 1.6 02/03/2007 19:00:00 4.1 0.6 5.7 2.6 4 0.6 5.7 2.6 3.2 0.5 4.6 1.9 308 8 309 165 1.2 0.1 1.8 0.9 02/03/2007 19:10:00 3.7 0.4 4.9 2.6 3.6 0.4 4.9 2.3 2.8 0.5 3.8 1.5 310 10 312 165 0.9 0.2 1.4 0.7 02/03/2007 19:20:00 3.8 0.7 5.3 2.6 3.7 0.7 5.3 2.3 2.7 0.5 4.2 1.5 301 6 297 165 0.6 0 1.1 0.2 02/03/2007 19:30:00 5.2 0.6 6.5 3 5.3 0.6 6.5 3.4 4.4 0.8 6.5 2.6 290 6 285 165 1.6 0.3 2.3 0.9 02/03/2007 19:40:00 4.2 0.8 5.7 2.6 4.1 0.8 5.7 2.6 3.3 0.7 5.3 1.9 290 5 295 165 1.8 0.1 2.1 1.4 02/03/2007 19:50:00 2.8 0.7 4.6 1.1 2.8 0.7 4.6 1.1 2.3 0.7 3.4 0.4 283 5 276 165 1.4 0.1 1.6 1.1 02/03/2007 20:00:00 1.7 0.7 3.8 0.4 1.4 0.7 3.8 0.4 0.8 0.5 2.3 0.4 299 11 308 165 0.9 0.1 1.4 0.9 02/03/2007 20:10:00 3 0.5 4.6 1.9 2.9 0.6 4.6 1.9 1.7 0.6 3.8 0.4 294 7 316 165 0.9 0.2 1.6 0.7 02/03/2007 20:20:00 2.3 0.5 3.4 0.7 2.3 0.5 3.4 1.1 1.3 0.5 2.6 0.4 288 8 277 165 1.5 0 1.8 1.4 02/03/2007 20:30:00 2.8 0.5 4.2 1.9 2.7 0.5 4.2 1.5 1.9 0.6 3.8 0.4 290 5 297 165 1.5 0 1.8 1.4 02/03/2007 20:40:00 2.8 0.6 4.2 1.5 2.7 0.7 4.2 1.1 1.7 0.8 3.4 0.4 289 6 282 165 1.3 0.2 1.8 0.9 02/03/2007 20:50:00 1.6 0.7 3 0.4 1.4 0.7 2.6 0.4 0.9 0.5 1.9 0.4 295 11 292 165 1.1 0 1.4 0.7 02/03/2007 21:00:00 1.6 0.4 3 0.7 1.2 0.5 3 0.4 1.3 0.5 2.3 0.4 317 22 282 165 0.6 0 0.9 0.2 02/03/2007 21:10:00 1.7 0.6 2.6 0.7 1 0.6 2.3 0.4 1.5 0.6 2.6 0.4 340 7 343 165 -0.1 0.1 0.4 -0.3 02/03/2007 21:20:00 0.9 0.5 1.9 0.4 0.4 0.1 1.1 0.4 0.7 0.4 1.9 0.4 342 15 341 165 -0.1 0.2 0.4 -0.3 02/03/2007 21:30:00 1.4 0.8 3 0.4 1 0.8 3 0.4 0.9 0.7 2.6 0.4 285 17 288 165 0.5 0.2 0.9 0.2 02/03/2007 21:40:00 1.4 0.7 3.4 0.4 1.7 0.6 3 0.4 0.9 0.7 2.6 0.4 262 14 278 165 0.9 0.2 1.4 0.2 02/03/2007 21:50:00 2.9 0.9 4.6 0.7 3.1 0.7 4.6 1.9 2.7 0.5 3.8 1.1 278 9 289 165 0.7 0.2 1.1 -0.1 02/03/2007 22:00:00 3.7 0.2 4.2 3 3.7 0.2 4.2 3 2.7 0.4 3.8 1.5 291 4 291 165 1 0 1.4 0.9 02/03/2007 22:10:00 3.4 0.4 4.2 2.3 3.4 0.4 4.6 2.3 3.1 0.5 4.2 1.5 286 5 293 165 1 0 1.4 0.9 02/03/2007 22:20:00 3.5 0.4 4.6 2.3 3.4 0.5 4.6 2.3 2.6 0.5 3.8 1.1 303 6 304 165 1.1 0 1.4 0.9 02/03/2007 22:30:00 3.6 0.5 4.6 1.9 3.6 0.5 4.6 2.3 2.4 0.4 4.2 1.1 300 3 299 165 1 0 1.4 0.9 02/03/2007 22:40:00 3.4 0.5 4.6 1.9 3.3 0.5 4.6 1.9 2.8 0.5 4.2 1.5 306 5 300 165 1.3 0.1 1.6 0.9 02/03/2007 22:50:00 3.6 0.4 5.3 2.6 3.5 0.5 4.9 2.3 3.2 0.5 4.9 2.3 313 8 322 165 0.8 0.1 1.6 0.4 02/03/2007 23:00:00 4 0.7 5.7 2.6 3.9 0.7 5.7 2.6 3.3 0.8 5.3 1.9 310 7 325 165 1.1 0.1 1.6 0.9 02/03/2007 23:10:00 5.1 0.5 6.1 3.8 5.1 0.5 6.1 3.8 4.5 0.5 5.7 3 312 6 305 165 1.1 0 1.4 0.9 02/03/2007 23:20:00 4.8 0.8 7.2 2.6 4.7 0.8 6.8 2.6 4.1 0.8 6.1 1.9 308 7 308 165 1.1 0.1 1.4 0.9 02/03/2007 23:30:00 5.1 1 7.2 1.9 5 1 7.2 1.9 4.5 0.7 6.5 2.6 311 9 301 165 0.7 0.2 1.4 0.2 02/03/2007 23:40:00 5.5 1 7.6 3 5.3 1 7.6 3 4.5 0.7 6.5 2.6 311 13 300 165 0.3 0.1 0.7 0.2 02/03/2007 23:50:00 7.6 0.5 9.1 5.7 7.6 0.5 9.1 5.7 6.6 0.9 8.8 4.2 292 4 300 165 0.5 0.2 0.9 0.2 02/04/2007 00:00:00 8.6 0.8 10.7 6.8 8.6 0.8 11.1 6.5 6.7 1 9.1 4.9 295 5 285 165 0.6 0 0.9 0.4 02/04/2007 00:10:00 7.1 0.7 8.8 5.3 7.2 0.7 8.8 5.3 5.3 0.8 7.6 3.4 296 4 297 165 0.4 0 0.7 0.2 02/04/2007 00:20:00 6.6 0.8 8.4 4.2 6.7 0.8 8.8 3.8 5.1 0.7 7.6 3 300 7 291 165 0.5 0 0.9 0.2 02/04/2007 00:30:00 6.5 0.6 8 4.9 6.5 0.6 8 5.3 5.2 0.7 7.2 3.4 302 7 302 165 0.6 0.1 1.1 0.2 02/04/2007 00:40:00 6.4 0.7 8.4 4.9 6.4 0.7 8.4 4.9 5.1 0.9 8 3.4 300 7 300 165 0.7 0.3 1.4 0.2 02/04/2007 00:50:00 6.4 0.8 8.4 4.2 6.4 0.8 8.4 4.2 5.1 1 8 3.4 297 6 296 165 0.2 0.2 0.9 -0.5 02/04/2007 01:00:00 7.1 0.6 9.1 4.9 7.2 0.6 9.1 4.9 5.8 1 8.4 4.2 296 5 286 165 0.3 0.1 0.7 -0.5 02/04/2007 01:10:00 6.7 0.8 8.4 4.6 6.7 0.8 8.8 4.6 5.3 1 8.4 3 297 5 297 165 0.3 0.1 0.7 -0.1 02/04/2007 01:20:00 5.3 0.8 6.8 3.4 5.4 0.8 6.8 3.4 4.2 0.7 6.5 2.6 298 7 297 165 0.6 0.1 1.1 0.2 02/04/2007 01:30:00 6.2 0.8 8 4.6 6.3 0.8 8.4 4.2 5.4 0.9 7.6 2.6 295 8 294 165 0.5 0.3 1.1 -0.3 02/04/2007 01:40:00 8.3 0.6 9.5 6.8 8.4 0.6 9.9 6.8 7.7 0.8 9.1 5.3 287 4 292 165 0.1 0 0.7 -0.1 02/04/2007 01:50:00 8 0.7 9.5 6.5 8.1 0.7 9.5 6.5 8.3 0.7 10.3 5.7 282 4 288 165 0.1 0 0.2 -0.3 02/04/2007 02:00:00 8.3 0.7 10.3 6.8 8.4 0.6 9.9 6.5 7.4 1 9.1 4.9 292 6 290 165 -0.2 0 -0.1 -0.3 02/04/2007 02:10:00 9.2 0.5 10.3 7.6 9.3 0.5 10.3 7.6 6.8 0.8 9.1 4.9 299 4 296 165 -0.2 0.1 0.2 -0.3 02/04/2007 02:20:00 9.3 0.7 11.1 6.8 9.4 0.7 11.1 7.2 6.7 0.7 8.8 4.9 302 4 301 165 -0.3 0.1 -0.1 -0.5 02/04/2007 02:30:00 7.2 1 9.9 4.9 7.4 0.9 9.9 5.3 5.8 1 9.1 3.8 300 5 298 165 -0.1 0 0.2 -0.5 02/04/2007 02:40:00 6.8 0.7 8.8 5.3 7.1 0.6 8.8 5.7 6.6 1.1 9.5 4.2 290 6 284 165 0.2 0.2 0.7 -0.5 02/04/2007 02:50:00 6.4 0.8 8.4 4.2 6.7 0.7 8.4 5.3 6.4 1 8.8 3.8 287 6 300 165 0.2 0.1 0.7 -0.1 02/04/2007 03:00:00 7.9 0.8 10.3 5.3 8.1 0.7 10.3 5.7 7.7 1 9.5 4.9 289 6 292 165 0.1 0.1 0.7 -0.3 02/04/2007 03:10:00 8.6 0.9 10.7 6.5 8.7 0.9 11.1 6.5 8.2 1.1 11.1 4.9 288 6 291 165 -0.1 0 0.2 -0.3 02/04/2007 03:20:00 8.6 0.8 11.1 6.8 8.8 0.8 11.1 6.8 8.6 0.9 11.1 6.1 287 5 283 165 -0.5 0.2 -0.1 -1.2 02/04/2007 03:30:00 8.3 0.6 9.9 6.5 8.4 0.6 9.9 6.8 7.4 1.2 10.3 4.6 293 4 291 165 -0.7 0.2 -0.1 -1.4 02/04/2007 03:40:00 8.2 0.6 9.5 6.1 8.3 0.5 9.5 6.5 6.4 0.8 8.8 3.8 295 3 292 165 -0.5 0 -0.1 -0.8 02/04/2007 03:50:00 7.2 0.6 8.4 5.3 7.3 0.5 8.4 5.7 5.6 0.9 7.6 3.4 295 5 292 165 -0.6 0.4 0.2 -1.4 02/04/2007 04:00:00 5.9 0.7 8 4.2 6.1 0.7 8 4.2 6.1 0.9 8.4 3.4 282 5 279 165 0.8 0.2 1.4 0.2 02/04/2007 04:10:00 7.2 1 9.1 4.9 7.3 0.9 9.1 5.3 7 1.1 9.1 4.2 285 5 282 165 0.1 0.4 0.9 -0.5 02/04/2007 04:20:00 6.8 0.5 8.4 5.7 6.9 0.5 8.4 5.3 6.7 0.7 8.4 4.6 286 4 286 165 -0.3 0.2 -0.1 -0.8 02/04/2007 04:30:00 6.9 0.5 8 5.3 7.1 0.6 8.4 4.9 6.2 1 8.4 3.4 292 5 295 165 0 0.2 0.7 -0.8 02/04/2007 04:40:00 5.2 0.7 7.6 4.2 5.4 0.7 7.6 3.8 4.2 0.7 6.1 2.6 301 6 300 165 0.6 0.1 0.9 0.2 02/04/2007 04:50:00 6.3 0.8 8 4.6 6.4 0.8 8 4.6 5.3 1.1 8 3 292 6 287 165 0.7 0.1 0.9 0.2 02/04/2007 05:00:00 7.1 0.6 8.8 5.7 7.1 0.6 8.8 5.7 5.7 0.9 8.4 3.8 294 5 291 165 0.1 0.1 0.4 -0.8 02/04/2007 05:10:00 6.4 0.6 8 4.9 6.5 0.6 8 4.9 5.3 0.8 7.2 3.4 292 4 298 165 -0.1 0 0.2 -0.3 02/04/2007 05:20:00 5.2 0.5 6.5 3.8 5.4 0.5 6.5 4.2 5.2 0.6 6.5 3.8 285 4 286 165 0 0.1 0.2 -0.5 02/04/2007 05:30:00 4.8 0.4 5.7 3.8 4.9 0.4 5.7 3.8 4.8 0.4 6.1 3 284 4 287 165 0.3 0.2 0.7 -0.1 02/04/2007 05:40:00 4.1 0.4 4.9 2.3 4.2 0.4 5.3 3 4.1 0.5 5.7 2.6 280 5 288 165 0.7 0 0.9 0.2 02/04/2007 05:50:00 2.8 0.5 4.2 1.1 3 0.3 4.2 2.3 2.9 0.3 3.8 1.9 259 11 284 165 0.9 0.1 1.4 0.4 02/04/2007 06:00:00 2.6 0.6 4.2 1.1 3.1 0.4 4.2 1.9 3 0.4 4.2 2.3 257 8 247 165 1.4 0.2 1.8 0.9 02/04/2007 06:10:00 3 0.6 4.2 1.5 3.4 0.3 4.2 2.6 3.3 0.3 4.2 2.3 253 15 244 165 0.9 0.2 1.6 0.7 02/04/2007 06:20:00 2.8 0.6 4.2 1.1 3.4 0.5 4.6 1.9 3.3 0.5 4.2 1.9 262 6 275 165 1.3 0.1 1.6 0.9 02/04/2007 06:30:00 2.8 0.6 4.2 1.1 3.1 0.7 4.2 1.1 3 0.8 4.2 0.7 274 8 268 165 1.5 0 1.8 1.4 02/04/2007 06:40:00 2.4 0.6 3.8 1.1 2.6 0.6 3.8 1.1 2.5 0.5 3.8 0.7 266 7 253 165 1.7 0 1.8 1.4 02/04/2007 06:50:00 3.1 0.3 3.8 1.9 3.3 0.3 4.2 2.6 3 0.4 3.8 1.9 264 4 264 165 1.7 0 1.8 1.4 02/04/2007 07:00:00 2.7 0.4 3.8 1.9 2.8 0.4 3.8 2.3 2.7 0.4 3.8 1.5 277 8 272 165 1.8 0.1 2.1 1.4 02/04/2007 07:10:00 2.8 0.5 3.8 1.5 2.9 0.6 3.8 1.5 2.9 0.6 3.8 1.5 274 7 273 165 1.8 0.1 2.1 1.4 02/04/2007 07:20:00 3 0.5 4.2 1.5 3.5 0.4 4.2 2.6 3.4 0.4 4.2 2.6 265 6 266 165 1.8 0.1 2.1 1.4 02/04/2007 07:30:00 3.5 0.6 4.9 1.9 3.8 0.5 4.9 2.6 3.6 0.5 4.9 2.6 269 5 278 165 1.7 0 1.8 1.4 02/04/2007 07:40:00 3 0.5 4.2 1.5 3.1 0.5 4.2 1.5 3 0.5 4.6 1.9 278 3 284 165 2 0 2.3 1.4 02/04/2007 07:50:00 2.7 0.4 3.8 1.9 2.6 0.4 3.8 1.5 2.4 0.4 3.4 1.1 286 7 287 165 2.3 0 2.6 1.8 02/04/2007 08:00:00 2.9 0.4 3.8 2.3 2.8 0.4 3.8 1.9 2 0.4 3 0.7 294 5 293 165 2.3 0.1 2.6 1.8 02/04/2007 08:10:00 3 0.5 4.9 1.9 2.9 0.6 4.6 1.9 2.5 0.7 4.6 1.1 291 4 285 165 2.6 0 2.8 2.1 02/04/2007 08:20:00 3.6 0.4 4.6 2.6 3.6 0.4 4.6 2.6 2.9 0.5 4.2 1.5 290 4 289 165 2.7 0 3 2.1 02/04/2007 08:30:00 3.5 0.4 4.2 2.6 3.6 0.4 4.6 2.6 2.7 0.6 3.8 1.1 284 8 295 165 2.8 0.1 3.3 2.3 02/04/2007 08:40:00 3.9 0.4 4.9 2.6 4 0.3 4.9 3 3.5 0.3 4.2 2.3 279 6 282 165 3 0 3.3 2.8 02/04/2007 08:50:00 4.2 0.4 5.3 3 4.2 0.4 5.3 3 3.9 0.5 5.3 2.6 281 5 278 165 2.8 0 3 2.6 02/04/2007 09:00:00 2.9 0.7 4.6 1.1 2.8 0.8 4.6 0.7 2.8 0.8 4.9 0.7 286 6 278 165 2.9 0.2 3.5 2.6 02/04/2007 09:10:00 3.3 0.8 4.9 1.5 3.2 0.8 4.9 1.1 3.3 0.8 4.9 1.5 281 7 277 165 3.6 0 4 3.3 02/04/2007 09:20:00 3.7 0.7 4.9 1.9 3.8 0.5 4.6 2.3 3.8 0.5 4.6 2.6 272 12 291 165 3.2 0.2 4 2.6 02/04/2007 09:30:00 3.4 1.4 5.7 0.4 3.5 1.6 5.7 0.4 3.2 1.7 5.3 0.4 246 18 247 165 2.7 0.3 3.3 1.8 02/04/2007 09:40:00 3.7 0.8 5.7 2.3 5.2 0.4 6.1 4.2 4.7 0.5 5.7 3.4 265 6 275 165 3 0.1 3.3 2.3 02/04/2007 09:50:00 5.4 0.4 6.1 4.2 5.4 0.4 6.1 4.2 4.8 0.8 6.1 2.3 284 6 276 165 3.2 0.2 3.8 2.8 02/04/2007 10:00:00 4.4 0.4 5.3 3.4 4.4 0.4 5.3 3.4 3.2 0.6 4.9 2.3 293 4 291 165 3.9 0.1 4.3 3.5 02/04/2007 10:10:00 3.4 1.3 5.3 0.7 3.5 1.1 5.3 0.7 2.1 1.4 4.6 0.4 282 10 291 165 4.3 0.4 5.5 3.8 02/04/2007 10:20:00 0.9 0.5 2.3 0.4 1.1 0.6 3 0.4 0.7 0.4 1.9 0.4 236 33 249 165 5.4 0.1 6 5 02/04/2007 10:30:00 0.7 0.4 2.3 0.4 0.7 0.5 2.6 0.4 1.1 0.6 2.6 0.4 184 41 265 165 5.1 0.3 5.7 4.5 02/04/2007 10:40:00 1.5 0.5 2.6 0.4 2 0.7 3.4 0.4 1.3 0.6 2.6 0.4 268 17 272 165 4.8 0.3 5.7 4.3 02/04/2007 10:50:00 0.6 0.4 2.3 0.4 0.7 0.4 2.3 0.4 0.8 0.4 2.6 0.4 287 22 283 165 5.1 0.3 5.7 4.8 02/04/2007 11:00:00 1.1 1 3.4 0.4 1.1 1 3.4 0.4 1.2 1 3.4 0.4 290 32 326 165 5.4 0.2 5.7 4.5 02/04/2007 11:10:00 2.1 0.7 3.4 0.4 2 0.8 3.4 0.4 2.1 0.5 3.4 1.1 320 19 307 165 4 0.2 4.8 3.5 02/04/2007 11:20:00 0.4 0.2 1.1 0.4 0.4 0.2 1.5 0.4 0.6 0.3 1.9 0.4 352 12 4 165 5.1 0.9 7 4 02/04/2007 11:30:00 0.4 0.2 1.5 0.4 0.4 0.2 1.5 0.4 0.4 0.2 1.1 0.4 280 64 337 165 6.2 0.3 7 5.7 02/04/2007 11:40:00 0.4 0 0.4 0.4 0.5 0.2 1.1 0.4 0.4 0 0.4 0.4 337 0 165 165 6.2 0.4 7.3 5.7 02/04/2007 11:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0.1 0.7 0.4 326 33 165 165 6.9 0.4 7.5 5.7 02/04/2007 12:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 220 0 165 165 5.7 0 6 5.5 02/04/2007 12:10:00 0.4 0 0.4 0.4 0.4 0.1 0.7 0.4 0.4 0.1 0.7 0.4 220 0 165 165 5.2 0.3 5.7 4.8 02/04/2007 12:20:00 1 0.3 1.5 0.4 1.5 0.3 1.9 0.4 1.4 0.4 1.9 0.4 307 21 302 165 5.6 0.2 6.2 5 02/04/2007 12:30:00 1.1 0.4 1.9 0.4 1.3 0.4 1.9 0.7 1.2 0.5 1.9 0.4 330 0 330 165 5.7 0 5.7 5.5 02/04/2007 12:40:00 0.7 0.4 1.5 0.4 0.8 0.5 1.9 0.4 1.1 0.5 1.9 0.4 359 53 330 165 6.1 0.4 7 5.5 02/04/2007 12:50:00 0.4 0 0.7 0.4 0.4 0.2 1.1 0.4 0.5 0.2 1.1 0.4 74 15 68 165 6.4 0.3 7 5.7 02/04/2007 13:00:00 0.9 0.4 1.5 0.4 0.7 0.3 1.5 0.4 1.4 0.4 2.3 0.4 14 29 358 165 6.9 0 7.3 6.7 02/04/2007 13:10:00 0.4 0.2 1.5 0.4 0.4 0.2 1.5 0.4 0.4 0.2 1.5 0.4 77 45 98 165 6.6 0.3 7.3 6 02/04/2007 13:20:00 0.5 0.3 1.5 0.4 0.5 0.3 1.5 0.4 0.5 0.2 1.5 0.4 204 29 192 165 6.8 0.1 7.3 6.2 02/04/2007 13:30:00 0.4 0.2 1.1 0.4 0.4 0.2 1.1 0.4 0.5 0.3 1.5 0.4 165 35 152 165 6.7 0.4 7.5 6.2 02/04/2007 13:40:00 1.1 0.3 1.5 0.4 1.1 0.3 1.5 0.4 1.1 0.3 1.5 0.4 160 6 157 165 5.6 0.3 6.2 5.2 02/04/2007 13:50:00 0.6 0.3 1.5 0.4 0.7 0.3 1.5 0.4 0.7 0.3 1.5 0.4 199 28 175 165 5.7 0.2 6 5.2 02/04/2007 14:00:00 0.4 0.2 1.5 0.4 0.4 0.2 1.5 0.4 0.4 0.2 1.1 0.4 248 2 265 165 5.7 0.2 6 5.2 02/04/2007 14:10:00 0.9 0.5 1.9 0.4 1.1 0.6 2.3 0.4 0.9 0.5 1.9 0.4 262 9 268 165 6.2 0.3 6.7 5.7 02/04/2007 14:20:00 0.6 0.3 1.1 0.4 0.7 0.4 1.9 0.4 0.4 0.2 1.1 0.4 268 7 260 165 6.9 0.6 7.8 5.7 02/04/2007 14:30:00 0.9 0.4 1.9 0.4 1 0.5 2.3 0.4 0.8 0.4 1.9 0.4 258 13 249 165 7.4 0.3 8 7 02/04/2007 14:40:00 0.9 0.5 1.9 0.4 1.1 0.6 2.3 0.4 1 0.5 2.3 0.4 252 5 255 165 6.3 0.4 7.3 5.7 02/04/2007 14:50:00 0.5 0.3 1.5 0.4 0.6 0.3 1.5 0.4 0.4 0.2 1.5 0.4 264 21 287 165 6.6 0.3 7 6 02/04/2007 15:00:00 0.4 0.2 1.1 0.4 0.4 0.2 1.1 0.4 0.4 0.2 1.1 0.4 285 0 285 165 6.1 0.3 6.5 5.5 02/04/2007 15:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0.1 0.7 0.4 285 0 165 165 6.4 0.4 7.3 5.7 02/04/2007 15:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 310 72 165 165 6.7 0.1 7.3 6.5 02/04/2007 15:30:00 0.4 0 0.7 0.4 0.4 0 0.7 0.4 0.4 0.2 1.1 0.4 147 22 61 165 6.2 0.3 7 5.7 02/04/2007 15:40:00 0.7 0.4 1.9 0.4 0.7 0.4 1.9 0.4 0.9 0.5 1.9 0.4 38 7 36 165 5.7 0.2 6.2 5.2 02/04/2007 15:50:00 0.5 0.3 1.5 0.4 0.5 0.3 1.5 0.4 0.4 0.2 1.5 0.4 105 22 111 165 6.2 0.1 6.5 5.7 02/04/2007 16:00:00 0.4 0 0.7 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 113 1 112 165 5.9 0.3 6.2 5.2 02/04/2007 16:10:00 0.6 0.3 1.5 0.4 0.5 0.2 1.1 0.4 0.4 0.1 0.7 0.4 112 0 112 165 5.5 0.3 6 5 02/04/2007 16:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.7 0.4 112 0 165 165 5.4 0.3 6 4.8 02/04/2007 16:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.7 0.4 113 1 165 165 4.8 0.1 5.2 4.5 02/04/2007 16:40:00 1 0.4 1.5 0.4 0.8 0.3 1.5 0.4 0.7 0.3 1.5 0.4 148 29 154 165 4.8 0.2 5 4.3 02/04/2007 16:50:00 1.1 0.3 1.5 0.4 1 0.3 1.5 0.4 1.2 0.3 1.9 0.4 180 1 181 165 4.1 0.1 4.5 3.8 02/04/2007 17:00:00 1 0.5 1.9 0.4 0.9 0.4 1.5 0.4 0.9 0.5 1.9 0.4 180 1 180 165 4 0 4.3 3.8 02/04/2007 17:10:00 1.3 0.3 1.9 0.4 1.1 0.3 1.5 0.4 1.1 0.3 1.5 0.4 188 0 187 165 3.6 0.1 3.8 3.5 02/04/2007 17:20:00 1.1 0.3 1.5 0.4 0.9 0.3 1.5 0.4 1.1 0.4 1.9 0.4 185 6 187 165 3.2 0.3 3.8 2.6 02/04/2007 17:30:00 0.9 0.4 1.5 0.4 0.8 0.4 1.5 0.4 1 0.4 1.9 0.4 167 1 167 165 2.7 0 2.8 2.3 02/04/2007 17:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 167 1 165 165 2.8 0 3 2.6 02/04/2007 17:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 167 1 165 165 3 0 3.3 2.6 02/04/2007 18:00:00 0.7 0.3 1.1 0.4 0.7 0.3 1.1 0.4 0.7 0.3 1.5 0.4 236 82 166 165 3 0 3.3 2.8 02/04/2007 18:10:00 0.4 0.2 1.1 0.4 0.4 0.1 1.1 0.4 0.4 0.2 1.1 0.4 6 66 140 165 2.8 0 3 2.6 02/04/2007 18:20:00 0.4 0.1 0.7 0.4 0.4 0.1 0.7 0.4 0.4 0.1 0.7 0.4 142 0 142 165 2.6 0 2.8 2.6 02/04/2007 18:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 142 0 165 165 2.7 0 2.8 2.6 02/04/2007 18:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 142 0 165 165 2.4 0.1 2.8 1.8 02/04/2007 18:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 142 1 165 165 2 0.1 2.6 1.8 02/04/2007 19:00:00 0.4 0.1 0.7 0.4 0.4 0 0.7 0.4 0.4 0 0.4 0.4 142 0 143 165 2.6 0 2.8 2.3 02/04/2007 19:10:00 0.9 0.5 1.9 0.4 0.8 0.4 1.5 0.4 0.7 0.5 1.5 0.4 151 12 169 165 2.4 0 2.8 2.3 02/04/2007 19:20:00 1.6 0.3 2.3 0.7 1.6 0.3 2.3 0.7 1.6 0.3 2.3 0.7 166 4 160 165 2 0.1 2.6 1.6 02/04/2007 19:30:00 0.7 0.4 2.3 0.4 0.8 0.4 2.3 0.4 0.6 0.3 1.5 0.4 203 32 289 165 1.9 0 2.3 1.6 02/04/2007 19:40:00 1.6 0.5 2.6 0.4 1.8 0.4 2.6 0.7 1.4 0.4 2.6 0.4 273 12 287 165 2 0.1 2.3 1.6 02/04/2007 19:50:00 1.5 0.6 2.6 0.4 1.7 0.5 2.6 0.4 1.8 0.4 2.6 0.4 237 22 241 165 2.1 0 2.6 1.8 02/04/2007 20:00:00 1.8 0.2 2.3 1.5 1.8 0.2 2.3 1.5 1.9 0.2 2.6 1.1 195 5 207 165 2.1 0 2.3 1.8 02/04/2007 20:10:00 2.4 0.3 3 1.9 2.5 0.3 3 1.9 2.4 0.4 3 1.5 205 3 206 165 2.1 0 2.6 1.8 02/04/2007 20:20:00 2 0.2 2.6 1.5 2.1 0.2 2.6 1.9 2.2 0.2 2.6 1.9 207 2 204 165 2.2 0 2.6 1.8 02/04/2007 20:30:00 2.3 0.3 3 1.5 2.4 0.3 3 1.5 2.2 0.3 3 1.5 193 8 198 165 2.1 0.2 2.6 1.6 02/04/2007 20:40:00 2.5 0.3 3 1.9 2.5 0.3 3 1.9 2.5 0.4 3 1.5 203 1 202 165 2 0 2.3 1.8 02/04/2007 20:50:00 2.2 0.2 2.6 1.9 2.3 0.2 2.6 1.9 2.2 0.3 2.6 1.5 203 0 203 165 2.1 0 2.3 1.8 02/04/2007 21:00:00 2.1 0.3 2.6 1.5 2.2 0.3 2.6 1.5 2.2 0.2 2.6 1.9 203 0 203 165 2.3 0 2.6 2.1 02/04/2007 21:10:00 1.8 0.3 2.3 1.5 1.9 0.3 2.3 1.5 2 0.2 2.6 1.5 197 7 196 165 2.4 0 2.6 2.3 02/04/2007 21:20:00 0.9 0.6 2.3 0.4 1.2 0.5 2.3 0.7 1.2 0.5 2.3 0.4 195 2 189 165 2.3 0 2.8 2.1 02/04/2007 21:30:00 1.3 0.2 1.5 1.1 1.4 0.2 1.9 1.1 1.4 0.2 1.9 1.1 192 2 193 165 2.5 0 2.8 2.3 02/04/2007 21:40:00 0.5 0.2 1.5 0.4 0.6 0.3 1.5 0.4 0.4 0.2 1.5 0.4 183 0 184 165 2.4 0 2.8 2.1 02/04/2007 21:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 182 0 165 165 2.2 0 2.6 2.1 02/04/2007 22:00:00 0.4 0.1 1.1 0.4 0.5 0.3 1.5 0.4 0.4 0.1 1.5 0.4 181 4 174 165 2.3 0 2.6 2.1 02/04/2007 22:10:00 0.9 0.5 2.3 0.4 1.2 0.4 2.3 0.7 1.2 0.4 2.3 0.7 163 3 154 165 2.2 0.1 2.6 1.8 02/04/2007 22:20:00 2 0.3 2.6 1.5 2.1 0.3 2.6 1.5 1.9 0.2 2.3 1.5 153 2 157 165 2 0.1 2.3 1.8 02/04/2007 22:30:00 2.8 0.3 3.4 2.3 2.8 0.3 3.4 2.3 2.6 0.2 3 1.9 154 2 153 165 1.6 0.2 2.3 1.1 02/04/2007 22:40:00 2.9 0.2 3 2.6 2.9 0.2 3 2.6 3 0.2 3.4 2.6 158 4 153 165 1.3 0.1 1.6 0.9 02/04/2007 22:50:00 2.9 0.3 3.4 2.3 2.8 0.2 3.4 2.3 3 0.3 3.4 2.3 161 5 161 165 1.6 0 1.8 1.4 02/04/2007 23:00:00 2.6 0.3 3.4 2.3 2.6 0.2 3 2.3 2.6 0.3 3.4 1.9 171 5 179 165 1.6 0 1.8 1.4 02/04/2007 23:10:00 2.8 0.3 3.4 2.3 2.7 0.2 3.4 2.3 2.8 0.2 3.4 1.9 177 4 178 165 1.7 0 1.8 1.6 02/04/2007 23:20:00 3 0.3 3.4 2.3 2.9 0.2 3.4 2.3 3 0.3 3.4 2.3 181 3 181 165 1.6 0 1.8 1.4 02/04/2007 23:30:00 2.6 0.3 3 1.9 2.6 0.2 3 1.9 2.6 0.2 3 1.9 173 8 184 165 1.3 0 1.6 1.1 02/04/2007 23:40:00 2.6 0.2 3 2.3 2.6 0.2 3 2.3 2.7 0.3 3.4 2.3 168 5 179 165 1.4 0.1 1.8 1.1 02/04/2007 23:50:00 1.8 0.4 2.6 1.1 1.8 0.4 2.6 1.1 1.6 0.4 2.6 1.1 172 5 174 165 1.8 0 1.8 1.6 02/05/2007 00:00:00 1.4 0.4 1.9 0.7 1.6 0.3 2.3 1.1 1.5 0.3 1.9 0.7 158 3 164 165 1.9 0 2.3 1.6 02/05/2007 00:10:00 1 0.2 1.5 0.4 1.2 0.2 1.5 0.7 1.1 0.2 1.5 0.7 150 0 150 165 2 0 2.3 1.8 02/05/2007 00:20:00 0.6 0.4 1.9 0.4 0.9 0.3 1.9 0.4 0.8 0.5 2.3 0.4 112 47 7 165 2.3 0 2.6 2.1 02/05/2007 00:30:00 1 0.4 2.3 0.4 1.2 0.4 2.3 0.4 1.2 0.5 2.3 0.4 81 30 34 165 2 0 2.3 1.8 02/05/2007 00:40:00 1.7 0.6 2.6 0.7 1.9 0.5 3 1.1 1.8 0.5 3 0.7 112 14 129 165 2 0 2.3 1.8 02/05/2007 00:50:00 2.5 0.2 3 1.9 2.6 0.2 3 2.3 2.6 0.2 3 2.3 138 5 136 165 1.9 0.1 2.3 1.6 02/05/2007 01:00:00 2.1 0.3 2.6 1.5 2.2 0.3 3 1.5 2.1 0.4 3 1.5 134 5 143 165 1.8 0 1.8 1.6 02/05/2007 01:10:00 1.8 0.2 2.3 1.5 1.9 0.2 2.3 1.5 1.8 0.2 2.3 1.5 126 1 126 165 1.8 0 2.1 1.6 02/05/2007 01:20:00 1.5 0.2 1.9 1.1 1.7 0.2 2.3 1.1 1.5 0.2 2.3 1.1 122 3 123 165 1.7 0 2.1 1.6 02/05/2007 01:30:00 1.6 0.4 2.3 1.1 1.8 0.3 2.6 1.1 1.6 0.4 2.6 1.1 120 6 128 165 1.4 0.1 1.8 1.1 02/05/2007 01:40:00 2.2 0.2 2.6 1.5 2.3 0.2 2.6 1.9 2.2 0.2 2.6 1.9 131 0 131 165 1.4 0 1.6 1.4 02/05/2007 01:50:00 1.8 0.2 2.3 1.5 1.9 0.2 2.3 1.5 1.8 0.2 2.3 1.5 126 1 126 165 1.5 0 1.8 1.4 02/05/2007 02:00:00 1.4 0.3 1.9 0.7 1.5 0.3 2.3 1.1 1.4 0.3 2.3 0.7 125 1 126 165 1.4 0.1 1.8 1.1 02/05/2007 02:10:00 1.5 0.2 1.9 1.1 1.6 0.2 1.9 1.1 1.5 0.2 1.9 1.1 120 2 125 165 1.2 0 1.6 0.9 02/05/2007 02:20:00 2.2 0.4 2.6 1.5 2.2 0.4 2.6 1.5 2.2 0.4 2.6 1.1 143 14 141 165 1.1 0.1 1.4 0.7 02/05/2007 02:30:00 2.3 0.2 2.6 1.9 2.4 0.2 2.6 1.9 2.3 0.2 2.6 1.9 141 1 147 165 0.8 0.1 1.1 0.7 02/05/2007 02:40:00 2.1 0.3 2.6 1.9 2.2 0.3 2.6 1.9 2.1 0.3 2.6 1.9 147 3 141 165 0.8 0 1.1 0.7 02/05/2007 02:50:00 1.6 0.4 2.3 1.1 1.7 0.4 2.3 1.1 1.5 0.4 2.3 0.7 147 2 151 165 0.8 0.1 1.4 0.7 02/05/2007 03:00:00 1.5 0.1 1.9 1.1 1.5 0.1 1.9 1.1 1.4 0.2 1.9 1.1 145 1 145 165 0.9 0 1.4 0.7 02/05/2007 03:10:00 2.2 0.4 3 1.1 2.3 0.4 3 1.5 2.1 0.4 3 1.1 140 9 151 165 0.8 0 1.4 0.7 02/05/2007 03:20:00 2.6 0.2 3 2.3 2.7 0.2 3 2.3 2.7 0.2 3 2.3 144 2 147 165 0.4 0.1 0.7 0.2 02/05/2007 03:30:00 2.9 0.2 3.4 2.6 2.9 0.2 3 2.6 2.6 0.2 3 2.3 148 3 147 165 0.4 0 0.7 0.2 02/05/2007 03:40:00 2.7 0.2 3 2.3 2.8 0.2 3 2.6 2.5 0.2 3 1.9 140 4 144 165 0.5 0 0.9 0.2 02/05/2007 03:50:00 2.8 0.2 3.4 2.3 2.9 0.2 3.4 2.3 2.7 0.3 3.8 2.3 138 4 148 165 0.3 0.1 0.7 0.2 02/05/2007 04:00:00 3 0.3 3.8 2.3 3.1 0.3 3.8 2.3 2.8 0.3 3.4 1.9 145 3 146 165 0.3 0 0.7 0.2 02/05/2007 04:10:00 2.6 0.2 3 1.5 2.7 0.2 3 1.9 2.5 0.2 3 1.9 145 6 148 165 0.7 0.2 1.1 0.2 02/05/2007 04:20:00 2.4 0.2 3 1.9 2.5 0.2 3 1.9 2.2 0.2 2.6 1.5 137 2 140 165 1 0 1.4 0.9 02/05/2007 04:30:00 1.9 0.2 2.3 1.5 2.1 0.2 2.6 1.5 1.8 0.3 2.3 1.1 122 7 135 165 0.8 0.1 1.4 0.7 02/05/2007 04:40:00 1.3 0.3 1.9 0.4 1.5 0.3 2.3 0.4 1.1 0.4 1.9 0.4 103 9 115 165 0.7 0.1 0.9 0.7 02/05/2007 04:50:00 2 0.4 2.6 1.1 2 0.4 2.6 1.1 1.9 0.3 2.6 1.5 130 3 130 165 0.4 0.2 1.4 -0.1 02/05/2007 05:00:00 2.6 0.2 3 2.3 2.6 0.2 3 2.3 2.4 0.2 2.6 2.3 126 2 128 165 -0.2 0 0.2 -0.3 02/05/2007 05:10:00 2.9 0.2 3.4 2.6 2.9 0.2 3.4 2.6 2.8 0.2 3.4 2.3 132 3 128 165 -0.3 0.1 -0.1 -0.5 02/05/2007 05:20:00 2.6 0.3 3.4 2.3 2.7 0.3 3.4 2.3 2.6 0.3 3 2.3 133 4 135 165 -0.5 0 -0.1 -0.8 02/05/2007 05:30:00 3 0.3 3.4 2.3 3 0.3 3.4 2.3 3.1 0.3 3.8 2.3 147 6 148 165 -0.8 0.1 -0.3 -1 02/05/2007 05:40:00 3 0.3 3.8 2.3 3 0.3 3.4 2.3 2.9 0.2 3.4 2.3 151 3 155 165 -1.2 0 -0.8 -1.4 02/05/2007 05:50:00 2 0.4 2.6 1.1 2 0.5 2.6 1.1 2 0.5 3 1.1 145 9 151 165 -1.3 0 -1 -1.4 02/05/2007 06:00:00 0.5 0.3 1.5 0.4 0.5 0.3 1.5 0.4 0.6 0.3 1.5 0.4 167 1 165 165 -1 0.2 -0.8 -1.4 02/05/2007 06:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 167 0 165 165 -0.8 0 -0.5 -1 02/05/2007 06:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0.1 0.7 0.4 167 0 165 165 -1 0 -0.5 -1.2 02/05/2007 06:30:00 0.4 0 0.4 0.4 0.6 0.3 1.1 0.4 0.7 0.3 1.1 0.4 167 1 165 165 -0.7 0.2 -0.3 -1.2 02/05/2007 06:40:00 1.3 0.5 1.9 0.4 1.5 0.3 1.9 0.7 1.5 0.3 1.9 0.7 164 1 165 165 -0.3 0 -0.1 -0.5 02/05/2007 06:50:00 1 0.5 1.9 0.4 1.2 0.4 1.9 0.4 1.2 0.4 2.3 0.4 164 0 165 165 -0.2 0 -0.1 -0.5 02/05/2007 07:00:00 0.4 0 0.4 0.4 0.5 0.2 1.1 0.4 0.5 0.2 1.1 0.4 165 0 165 165 -0.3 0 -0.1 -0.5 02/05/2007 07:10:00 0.5 0.2 1.1 0.4 0.7 0.3 1.1 0.4 0.6 0.3 1.5 0.4 165 0 165 165 -0.2 0.1 0.2 -0.3 02/05/2007 07:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.6 0.4 1.9 0.4 165 0 165 165 -0.5 0 -0.1 -0.8 02/05/2007 07:30:00 0.4 0.1 1.1 0.4 0.4 0.2 1.1 0.4 0.6 0.4 1.9 0.4 31 82 41 165 -0.2 0.2 0.4 -0.5 02/05/2007 07:40:00 0.9 0.3 1.5 0.4 1.2 0.2 1.9 0.7 1.5 0.2 2.3 1.1 36 9 36 165 0.4 0.1 0.7 0.2 02/05/2007 07:50:00 1 0.3 1.9 0.4 1.3 0.3 1.9 0.7 1.5 0.3 1.9 1.1 27 5 34 165 0.2 0 0.4 -0.1 02/05/2007 08:00:00 1 0.4 1.9 0.4 1.4 0.3 1.9 0.7 1.5 0.3 2.3 0.7 53 11 78 165 0.2 0.1 0.7 -0.1 02/05/2007 08:10:00 1.4 0.4 2.3 0.4 1.6 0.4 2.3 0.4 1.6 0.2 2.3 1.1 59 7 60 165 0.5 0 0.9 0.2 02/05/2007 08:20:00 2 0.3 3 0.7 2.1 0.3 3 1.1 2.1 0.3 2.6 1.5 49 8 56 165 0.3 0.2 0.7 -0.3 02/05/2007 08:30:00 2.3 0.3 3 1.5 2.4 0.3 3 1.5 2.2 0.3 3 1.5 52 7 56 165 0.1 0.1 0.4 -0.3 02/05/2007 08:40:00 2.5 0.3 3.4 1.5 2.6 0.3 3.4 1.9 2.2 0.3 3.4 1.5 69 10 69 165 0.1 0.2 0.7 -0.5 02/05/2007 08:50:00 2.3 0.3 3 1.5 2.4 0.3 3 1.1 2 0.4 3 0.7 81 13 76 165 -1.3 0.3 -0.5 -1.9 02/05/2007 09:00:00 2.1 0.2 2.6 1.5 2.2 0.2 2.6 1.9 2.1 0.3 2.6 1.1 99 2 99 165 -0.2 0.2 0.2 -0.8 02/05/2007 09:10:00 1.8 0.2 2.3 1.5 2 0.2 2.6 1.5 1.3 0.2 1.9 0.7 95 5 101 165 -1.8 0.7 -0.3 -2.6 02/05/2007 09:20:00 1.2 0.5 2.6 0.4 1.4 0.5 2.3 0.4 1 0.5 2.3 0.4 66 12 63 165 -1.8 0.1 -1.4 -2.6 02/05/2007 09:30:00 0.5 0.3 1.5 0.4 0.6 0.4 1.9 0.4 0.4 0.1 1.1 0.4 65 15 78 165 -2.8 0.3 -1.7 -3.3 02/05/2007 09:40:00 1.6 0.6 2.6 0.4 1.7 0.6 2.6 0.4 1.4 0.4 2.3 0.4 88 6 94 165 -2.4 0.3 -1.9 -3.3 02/05/2007 09:50:00 1.9 0.4 2.6 1.1 1.8 0.4 2.6 1.1 2.2 0.3 2.6 1.5 91 3 94 165 -2.6 0.4 -1.4 -3.3 02/05/2007 10:00:00 2.2 0.2 2.6 1.5 2.1 0.2 2.6 1.5 2.2 0.4 3 1.1 94 4 90 165 -1.3 0.2 -0.8 -1.9 02/05/2007 10:10:00 2.1 0.3 2.6 1.5 2.2 0.3 2.6 1.5 2.2 0.3 3 1.5 104 5 102 165 -0.8 0.1 -0.3 -1.2 02/05/2007 10:20:00 2.4 0.3 3 1.9 2.5 0.3 3.4 1.9 2.3 0.3 3 1.1 101 4 103 165 -0.5 0.2 -0.1 -1 02/05/2007 10:30:00 3 0.4 3.8 1.9 3 0.4 3.8 1.9 2.7 0.4 3.4 1.9 110 3 111 165 -1.4 0.5 -0.3 -2.1 02/05/2007 10:40:00 2.7 0.4 3.8 1.9 2.6 0.4 3.4 1.9 2.4 0.4 3.4 1.5 108 5 114 165 -2.2 0 -1.7 -2.4 02/05/2007 10:50:00 2.3 0.5 3.4 0.4 2 0.6 3.4 0.4 1.8 0.6 3 0.4 102 9 102 165 -1.9 0.2 -1.4 -2.4 02/05/2007 11:00:00 3 0.5 4.2 1.5 3 0.5 3.8 1.5 2.6 0.5 3.8 1.5 107 9 116 165 -1.6 0 -1.2 -1.9 02/05/2007 11:10:00 2.8 0.4 3.8 2.3 2.8 0.4 3.8 1.9 2.5 0.4 3.4 1.5 118 8 115 165 -1.8 0 -1.4 -1.9 02/05/2007 11:20:00 2.5 0.5 3.8 1.1 2.5 0.5 3.8 0.7 2.1 0.5 3.4 0.7 108 6 111 165 -1.3 0.2 -0.8 -1.7 02/05/2007 11:30:00 1.9 0.4 2.6 0.7 2 0.5 3 0.4 1.9 0.4 3 0.7 103 5 99 165 -0.8 0 -0.5 -1 02/05/2007 11:40:00 2.2 0.4 3 0.7 2.2 0.4 3 0.7 2.1 0.5 3 0.4 115 5 111 165 -1.3 0.1 -0.8 -1.4 02/05/2007 11:50:00 1.5 0.5 2.6 0.4 1.5 0.6 2.6 0.4 1.4 0.5 2.3 0.4 106 9 115 165 -1.3 0.1 -1 -1.7 02/05/2007 12:00:00 1.7 0.6 3.4 0.4 1.7 0.6 3.4 0.4 1.6 0.6 3 0.4 87 9 90 165 -0.8 0.1 -0.5 -1.2 02/05/2007 12:10:00 1.4 0.6 3 0.4 1.4 0.7 3 0.4 1.3 0.7 3 0.4 86 16 72 165 -0.8 0.1 -0.5 -1.2 02/05/2007 12:20:00 1.1 0.8 3.8 0.4 1.1 0.8 3.4 0.4 1.1 0.7 3 0.4 90 15 81 165 -1.1 0 -0.8 -1.2 02/05/2007 12:30:00 2.1 0.7 3.8 0.4 2 0.8 3.8 0.4 1.9 0.7 3.8 0.4 69 22 110 165 -1.3 0 -0.8 -1.4 02/05/2007 12:40:00 1.3 0.6 3.4 0.4 1 0.6 3 0.4 1.2 0.6 3 0.4 30 15 32 165 -0.9 0.1 -0.5 -1.2 02/05/2007 12:50:00 1.8 0.6 3 0.4 1.3 0.6 3 0.4 1.8 0.6 3 0.4 21 15 51 165 -0.6 0 -0.5 -0.8 02/05/2007 13:00:00 2.7 0.4 3.8 1.5 2.1 0.6 3.4 0.4 2.6 0.5 3.8 1.5 15 6 14 165 -0.6 0 -0.5 -0.8 02/05/2007 13:10:00 1.8 0.6 3 0.4 1.5 0.6 3 0.4 1.9 0.5 3 0.7 33 15 25 165 -0.8 0.1 -0.5 -1 02/05/2007 13:20:00 1 0.8 3.4 0.4 0.9 0.8 3.4 0.4 1.1 0.7 2.6 0.4 82 36 47 165 -0.8 0 -0.5 -1 02/05/2007 13:30:00 2.7 0.5 3.8 1.5 2.6 0.5 4.2 1.5 2.5 0.5 3.8 1.5 44 11 36 165 -0.9 0.1 -0.3 -1.2 02/05/2007 13:40:00 2.8 0.5 4.2 1.5 2.8 0.5 4.2 1.5 2.7 0.4 4.2 1.5 48 3 44 165 -0.9 0 -0.8 -1.2 02/05/2007 13:50:00 2.3 0.7 3.8 0.4 2.2 0.8 3.8 0.4 2.3 0.7 3.8 0.4 49 0 48 165 -0.8 0.1 -0.5 -1 02/05/2007 14:00:00 2.7 0.7 4.2 1.1 2.6 0.8 4.2 0.7 2.7 0.8 4.2 1.1 49 1 48 165 -0.9 0 -0.5 -1 02/05/2007 14:10:00 3.8 0.8 5.7 1.5 3.8 0.9 5.7 1.1 3.7 0.8 5.7 1.5 49 0 49 165 -0.9 0 -0.5 -1 02/05/2007 14:20:00 3.7 0.7 6.1 1.9 3.7 0.7 6.1 1.5 3.6 0.8 6.1 1.5 49 0 48 165 -0.9 0.1 -0.3 -1 02/05/2007 14:30:00 4.1 0.8 6.5 1.9 4.2 0.9 6.5 1.9 4.1 0.9 6.5 1.5 49 0 49 165 -0.9 0 -0.8 -1.2 02/05/2007 14:40:00 3.1 0.7 4.6 1.9 3.1 0.7 4.6 1.5 2.9 0.7 4.6 1.5 49 0 49 165 -0.8 0 -0.5 -1 02/05/2007 14:50:00 4 0.6 5.3 2.6 4.3 0.6 5.7 2.6 4.1 0.6 5.7 2.6 49 0 48 165 -0.6 0 -0.3 -0.8 02/05/2007 15:00:00 3.3 0.6 4.9 1.9 3.4 0.6 4.9 1.9 3.1 0.5 4.6 1.5 49 0 49 165 -0.4 0.1 0.2 -0.8 02/05/2007 15:10:00 2.3 0.8 4.6 1.1 2.4 0.9 4.6 1.1 2.3 0.6 4.6 1.1 49 0 49 165 -0.5 0 0.2 -0.8 02/05/2007 15:20:00 3.9 0.6 6.1 2.3 4 0.7 6.1 2.6 3.6 0.8 5.7 1.9 49 0 49 165 -0.4 0.1 -0.1 -0.8 02/05/2007 15:30:00 2.6 0.6 4.2 1.5 2.5 0.6 4.6 1.5 2.4 0.5 3.8 1.1 49 0 49 165 -0.3 0 -0.1 -0.5 02/05/2007 15:40:00 2.9 1 5.7 1.1 2.8 1 5.7 0.7 2.7 1 5.3 0.7 49 0 49 165 -0.3 0 -0.1 -0.5 02/05/2007 15:50:00 2.9 0.4 4.6 1.5 2.8 0.5 4.6 1.5 2.8 0.4 3.8 1.9 49 0 49 165 -0.2 0 -0.1 -0.3 02/05/2007 16:00:00 4.1 0.9 6.5 1.9 4.3 1 6.8 1.9 3.8 1 6.5 1.5 49 0 48 165 0 0.1 0.2 -0.3 02/05/2007 16:10:00 3.8 0.6 6.1 2.6 4.2 0.6 6.5 2.6 3.7 0.5 4.9 2.3 49 0 49 165 0.2 0 0.7 -0.1 02/05/2007 16:20:00 3.9 0.6 6.1 2.6 4.2 0.6 6.1 3 3.6 0.6 5.3 2.3 49 0 49 165 0.1 0 0.2 -0.1 02/05/2007 16:30:00 4.6 0.6 6.1 3 4.9 0.6 6.5 3.4 4.3 0.6 5.7 3 49 0 49 165 0.2 0.1 0.7 -0.1 02/05/2007 16:40:00 4.6 0.6 6.5 3.4 5 0.6 6.8 3.8 4.4 0.6 6.1 3 49 0 49 165 0.2 0 0.7 0.2 02/05/2007 16:50:00 5.9 0.6 7.6 4.6 6.2 0.6 7.6 4.6 5.7 0.6 7.2 3.8 49 0 49 165 0.4 0 0.7 0.2 02/05/2007 17:00:00 5.5 0.7 7.2 3.8 5.8 0.7 7.6 4.2 5.3 0.6 7.2 3.8 49 0 49 165 0.4 0 0.7 0.2 02/05/2007 17:10:00 6.2 0.8 8 4.2 6.6 0.8 8.4 4.6 6.2 0.8 8.4 4.2 49 0 49 165 0.5 0 0.9 0.4 02/05/2007 17:20:00 5.4 0.6 6.8 4.2 5.8 0.6 7.2 4.2 5.2 0.5 6.5 3.8 49 0 49 165 0.5 0 0.7 0.2 02/05/2007 17:30:00 4.7 0.4 6.8 3.8 5.1 0.4 7.2 3.8 4.5 0.5 6.5 3 49 0 49 165 0.5 0 0.7 0.4 02/05/2007 17:40:00 4 0.5 5.3 3.4 4.4 0.5 5.7 3.4 4.2 0.5 5.3 3 49 0 48 165 0.4 0 0.9 0.2 02/05/2007 17:50:00 3.8 0.4 4.9 3 4 0.4 5.3 3 4 0.3 5.3 3 49 0 49 165 0.5 0 0.7 0.2 02/05/2007 18:00:00 4.7 0.6 6.5 3 5 0.6 6.8 3.4 4.6 0.6 6.1 3 49 5 49 165 0.6 0 0.9 0.2 02/05/2007 18:10:00 4.8 0.7 6.8 3.4 5.1 0.7 7.2 3.4 4.7 0.6 6.8 3 49 6 56 165 0.8 0 0.9 0.7 02/05/2007 18:20:00 5.3 0.6 6.8 3.4 5.6 0.6 7.2 3.4 5.1 0.6 6.8 3.8 53 8 53 165 0.8 0 0.9 0.7 02/05/2007 18:30:00 5.8 0.9 8.4 4.2 6.3 0.9 8.8 4.2 5.8 0.8 8 3.8 78 7 82 165 0.9 0 1.4 0.9 02/05/2007 18:40:00 6.2 1 8.8 4.2 6.5 0.9 8.8 4.6 6.1 0.9 8.4 4.2 72 8 59 165 0.9 0 1.4 0.7 02/05/2007 18:50:00 7.1 0.8 8.8 5.3 7.4 0.7 8.8 5.7 7 0.7 9.1 4.9 79 11 85 165 0.8 0 1.1 0.9 02/05/2007 19:00:00 6.9 1 9.5 4.6 7.2 0.9 9.5 4.9 6.8 0.9 9.1 4.9 81 5 80 165 0.8 0 0.9 0.9 02/05/2007 19:10:00 6.9 0.9 9.1 4.2 7.2 0.8 9.1 4.9 6.8 0.8 8.8 4.2 83 7 75 165 0.9 0 1.1 0.9 02/05/2007 19:20:00 7 0.9 9.1 4.6 7.3 0.9 9.1 5.3 6.8 0.9 9.1 4.9 86 6 82 165 0.9 0 1.4 0.9 02/05/2007 19:30:00 8.2 0.9 9.5 5.3 8.4 0.8 9.9 5.7 7.7 1 9.9 5.3 96 6 91 165 0.9 0 1.4 0.9 02/05/2007 19:40:00 9 0.9 11.1 6.5 9.2 0.9 11.5 6.8 8.5 1 10.7 6.5 99 6 104 165 0.8 0 1.1 0.7 02/05/2007 19:50:00 8.3 1.1 10.7 5.7 8.5 1.1 11.1 6.1 7.8 1 10.7 5.7 99 9 102 165 0.8 0 1.1 0.7 02/05/2007 20:00:00 8.5 1 10.7 5.3 8.7 1 10.7 5.7 8.1 1 10.7 5.3 102 6 104 165 0.7 0 0.9 0.7 02/05/2007 20:10:00 8.6 0.9 10.3 5.7 8.8 0.8 10.7 6.1 8.1 0.9 10.3 5.3 98 6 103 165 0.6 0 0.9 0.4 02/05/2007 20:20:00 7.7 1 9.9 5.3 8 1 9.9 5.3 7.4 0.9 9.5 5.3 87 7 87 165 0.7 0 0.9 0.7 02/05/2007 20:30:00 7.9 0.7 9.5 5.7 8.1 0.7 9.9 6.5 7.5 0.8 9.5 5.3 93 8 77 165 0.7 0 1.1 0.7 02/05/2007 20:40:00 8.5 0.8 10.3 6.5 8.7 0.8 10.7 6.5 8 0.8 9.9 5.7 92 6 97 165 0.7 0 0.9 0.7 02/05/2007 20:50:00 7 1.3 10.7 3.8 7.3 1.3 11.1 4.2 6.9 1.2 9.5 4.2 82 7 73 165 0.6 0 0.9 0.4 02/05/2007 21:00:00 7.9 1.4 11.5 4.9 8.1 1.4 11.8 4.9 7.6 1.3 11.5 4.6 81 8 77 165 0.7 0.1 0.9 0.2 02/05/2007 21:10:00 7.7 1.3 11.1 5.3 7.9 1.3 11.5 5.7 7.4 1.2 10.3 5.3 86 7 69 165 0.8 0 1.1 0.7 02/05/2007 21:20:00 6.7 1.1 8.8 4.2 6.9 1.2 9.1 4.2 6.5 1 8.8 4.2 77 9 94 165 0.8 0.1 1.1 0.2 02/05/2007 21:30:00 5.9 0.8 8 4.2 6.2 0.8 8.4 4.2 5.7 0.8 7.6 3.4 60 8 57 165 0.5 0 0.9 -0.1 02/05/2007 21:40:00 6.1 1 8.4 3.8 6.3 1 8.4 3.8 6 0.9 8 3.8 66 8 61 165 0.5 0 0.7 0.4 02/05/2007 21:50:00 5.9 0.8 8.4 3.4 6.1 0.9 8.8 3.8 5.7 0.8 8.4 4.2 57 8 53 165 0.7 0 0.9 0.7 02/05/2007 22:00:00 5 0.7 6.8 3 5.1 0.8 7.2 2.6 4.8 0.7 6.5 2.6 59 7 63 165 0.7 0 0.9 0.2 02/05/2007 22:10:00 5.4 0.9 8 3.4 5.5 1 7.6 3.4 5.2 1 7.6 3 66 9 74 165 0.8 0 0.9 0.7 02/05/2007 22:20:00 6.2 0.9 8.8 4.6 6.4 0.9 8.8 4.6 6 0.9 8.8 4.2 70 9 84 165 0.9 0 1.1 0.4 02/05/2007 22:30:00 5.6 0.9 8 3.4 5.9 0.9 8.4 3.4 5.4 0.8 7.6 3.4 58 9 65 165 1 0 1.1 0.7 02/05/2007 22:40:00 5.7 1 8.8 3.4 5.9 1 8.4 3.4 5.5 0.9 8 3.8 62 7 64 165 1.1 0 1.4 0.9 02/05/2007 22:50:00 5.6 0.9 8 3.8 5.9 0.8 8.4 4.2 5.2 0.8 8 3.4 60 9 68 165 1.2 0 1.4 0.9 02/05/2007 23:00:00 5 0.8 6.8 2.6 5.2 0.8 7.2 2.6 4.7 0.7 6.5 2.6 52 9 41 165 1.2 0 1.6 0.9 02/05/2007 23:10:00 5.6 1.2 9.1 3 5.9 1.1 9.1 3 5.4 1 8.4 3 54 8 46 165 1.3 0 1.6 1.1 02/05/2007 23:20:00 7 1 9.5 5.3 7.2 1 9.9 5.3 6.6 0.9 9.1 4.6 59 11 43 165 1.4 0 1.6 0.9 02/05/2007 23:30:00 6.9 1.5 10.3 3 7.1 1.5 10.3 3 6.6 1.3 9.9 3.4 63 8 46 165 1.5 0 1.6 1.4 02/05/2007 23:40:00 5.9 1.1 9.1 3.4 6.1 1.1 9.1 3.4 5.7 1 8.8 3.4 50 10 74 165 1.5 0 1.6 1.4 02/05/2007 23:50:00 7.4 1 10.3 4.2 7.4 1 10.3 4.2 7.1 1 9.5 4.6 40 8 49 165 1.5 0 1.6 1.1 02/06/2007 00:00:00 6.6 1 9.5 3.8 6.8 1.1 9.9 4.2 6.5 1 9.1 4.6 56 8 57 165 1.6 0 1.8 1.4 02/06/2007 00:10:00 7.9 1.3 12.2 4.9 8 1.3 11.8 4.6 7.5 1.2 10.7 4.9 52 9 58 165 1.7 0 1.8 1.4 02/06/2007 00:20:00 7 1.2 9.5 3.4 7.2 1.1 9.9 3.8 6.8 1 9.5 4.2 54 9 37 165 1.8 0 1.8 1.4 02/06/2007 00:30:00 8.2 1.4 11.5 4.9 8.4 1.3 12.2 4.9 8.1 1.2 11.5 4.9 69 9 74 165 1.7 0 1.8 1.6 02/06/2007 00:40:00 7.1 1.1 9.5 4.6 7.4 1 9.5 4.6 7 1 9.5 4.6 80 9 73 165 1.6 0 1.8 1.4 02/06/2007 00:50:00 8.4 1.3 11.5 4.9 8.7 1.2 11.8 5.3 8 1.2 11.1 5.3 81 7 81 165 1.5 0 1.6 1.4 02/06/2007 01:00:00 9.1 1 11.1 6.1 9.2 1 11.5 6.5 8.6 1 11.8 6.5 73 7 84 165 1.7 0 1.8 1.6 02/06/2007 01:10:00 9.4 1 11.8 6.8 9.6 1 12.2 7.2 8.9 1 11.1 6.5 74 7 81 165 1.7 0 1.8 1.6 02/06/2007 01:20:00 9.7 1.2 13 6.8 9.8 1.2 12.6 7.2 9.2 1.1 11.8 6.5 78 6 83 165 1.7 0 1.8 1.6 02/06/2007 01:30:00 9 1.4 12.2 5.7 9.2 1.4 12.2 6.1 8.3 1.3 11.5 5.3 82 6 79 165 1.7 0 1.8 1.6 02/06/2007 01:40:00 8.3 1.3 11.5 4.6 8.6 1.2 11.5 4.6 7.7 1.2 10.7 4.9 78 7 90 165 1.7 0 1.8 1.6 02/06/2007 01:50:00 7.3 1.2 9.9 4.9 7.5 1.2 10.3 4.9 7.1 1.1 9.5 4.6 70 10 69 165 1.8 0 1.8 1.6 02/06/2007 02:00:00 8.4 1.4 11.5 5.3 8.6 1.4 11.8 5.3 8 1.1 11.1 5.3 81 15 79 165 1.7 0 1.8 1.6 02/06/2007 02:10:00 9 1.3 12.2 5.7 9.2 1.3 12.6 6.1 8.8 1.2 11.8 5.3 85 8 84 165 1.7 0 1.8 1.6 02/06/2007 02:20:00 9.6 1.1 11.8 6.8 9.8 1.1 12.2 7.2 9.6 1.1 11.8 7.2 86 5 89 165 1.6 0 1.8 1.4 02/06/2007 02:30:00 9 0.9 11.1 6.8 9.3 0.9 11.1 6.8 9 0.9 11.5 7.2 86 5 89 165 1.6 0 1.8 1.4 02/06/2007 02:40:00 8.9 1 11.1 5.7 9.2 0.9 11.1 6.1 9 0.9 10.7 7.2 85 5 87 165 1.6 0 1.8 1.4 02/06/2007 02:50:00 7.5 1.1 9.5 4.9 7.9 1 10.3 5.3 7.7 1 10.7 5.3 78 7 81 165 1.6 0 1.8 1.4 02/06/2007 03:00:00 6.9 1.3 10.3 4.2 7.2 1.3 10.7 4.6 7.2 1.2 10.7 4.6 70 10 73 165 1.5 0 1.6 1.4 02/06/2007 03:10:00 7.3 1.2 9.9 4.6 7.6 1.1 10.3 4.9 7.5 1.1 9.5 4.6 76 8 82 165 1.5 0.1 1.8 1.4 02/06/2007 03:20:00 6.4 1.1 9.1 3.8 6.8 1.1 9.1 4.2 6.7 1.1 9.5 4.6 78 7 81 165 1.7 0 1.8 1.4 02/06/2007 03:30:00 7 1.7 10.7 3.8 7.3 1.7 11.5 4.6 7.2 1.5 10.7 3.8 76 8 85 165 1.7 0 1.8 1.4 02/06/2007 03:40:00 8 1 10.3 5.7 8.3 0.9 10.7 6.1 8 1 10.3 5.3 83 6 80 165 1.7 0.1 1.8 1.4 02/06/2007 03:50:00 7.2 1.8 11.5 3.8 7.5 1.8 11.5 4.2 7.5 2 12.6 4.2 74 12 79 165 1.7 0.2 1.8 1.4 02/06/2007 04:00:00 10.3 1.1 13.3 6.5 10.4 1.1 14.1 6.8 10.6 1.2 13.3 7.6 91 8 99 165 1.7 0.1 1.8 1.4 02/06/2007 04:10:00 9.8 1.1 13 6.8 9.9 1.1 13 7.2 10.2 1.2 13.3 6.5 85 6 90 165 1.5 0.1 1.8 1.1 02/06/2007 04:20:00 9.3 1 11.8 6.5 9.3 1 10.7 6.5 9.6 1.5 12.2 6.1 91 5 84 165 1.6 0.2 1.8 1.4 02/06/2007 04:30:00 8.5 0.7 9.9 6.1 8.7 0.7 9.9 6.5 8.5 1 10.7 6.1 87 6 91 165 1.7 0.2 1.8 1.1 02/06/2007 04:40:00 7.2 0.8 9.5 5.3 7.4 0.8 9.5 5.7 7.1 0.9 9.5 4.9 90 8 84 165 1.7 0.2 1.8 1.4 02/06/2007 04:50:00 8.5 1.3 12.2 5.7 8.8 1.2 12.6 6.1 8.4 1.5 12.6 5.3 90 7 87 165 1.6 0 1.8 1.4 02/06/2007 05:00:00 9.4 1 12.2 6.8 9.7 1 12.6 6.8 9.4 1.1 12.2 6.5 83 6 90 165 1.7 0 1.8 1.6 02/06/2007 05:10:00 9 0.9 11.5 6.5 9.3 0.9 11.8 6.5 9.1 1 11.5 6.1 80 6 78 165 1.7 0 1.8 1.6 02/06/2007 05:20:00 8.3 0.9 9.9 5.7 8.5 0.9 10.3 6.1 8.3 1 11.5 6.1 78 7 80 165 1.5 0 1.8 1.1 02/06/2007 05:30:00 7.7 1.2 11.1 4.6 7.9 1.2 11.5 4.6 7.7 1.2 11.5 4.9 76 8 86 165 1.5 0.1 1.8 0.9 02/06/2007 05:40:00 7.4 1.1 9.9 4.9 7.6 1.2 10.3 5.3 7.4 1.2 10.3 4.6 75 10 88 165 1.6 0.1 1.8 1.1 02/06/2007 05:50:00 8.2 1.2 11.8 5.7 8.5 1.2 11.8 5.7 8.3 1.3 11.5 5.7 76 8 83 165 1.7 0.1 1.8 1.4 02/06/2007 06:00:00 9.2 0.9 11.5 6.1 9.9 1.1 12.2 7.2 9.3 1.1 12.2 6.5 82 6 83 165 1.6 0.1 1.8 1.4 02/06/2007 06:10:00 7.6 1.1 10.3 4.9 8 1.3 11.5 4.9 7.5 1.1 11.1 4.9 78 8 83 165 1.7 0.2 1.8 1.4 02/06/2007 06:20:00 8.3 0.9 10.3 5.7 8.7 1 11.1 6.1 8.1 1 10.7 5.3 85 9 74 165 1.7 0.1 1.8 1.4 02/06/2007 06:30:00 7.2 1.2 9.9 4.6 7.6 1.3 11.1 4.9 7.1 1.3 10.7 4.2 83 8 75 165 1.5 0.1 1.8 1.1 02/06/2007 06:40:00 8.2 1.3 11.8 5.7 8.6 1.4 12.2 5.7 8.2 1.4 11.8 5.3 78 8 84 165 1.6 0.2 1.8 1.4 02/06/2007 06:50:00 7.8 1.1 11.1 5.3 8.2 1.2 11.5 5.7 7.8 1.2 11.8 5.7 75 8 84 165 1.7 0.1 1.8 0.9 02/06/2007 07:00:00 8.4 0.9 11.1 6.1 8.9 1 11.5 6.5 8.3 1 11.1 6.1 78 7 92 165 1.7 0.1 1.8 1.4 02/06/2007 07:10:00 9.1 0.8 11.8 6.5 9.7 1 12.6 6.8 9.3 0.9 11.8 6.8 79 7 85 165 1.7 0.1 1.8 1.4 02/06/2007 07:20:00 10 0.9 12.2 7.2 10.4 1 12.6 7.6 9.8 1.1 12.6 6.8 80 6 83 165 1.8 0.1 1.8 1.4 02/06/2007 07:30:00 9.4 1.1 12.2 6.8 9.7 1.1 12.6 7.6 9 1.1 12.2 6.1 83 6 87 165 1.8 0.1 2.1 1.4 02/06/2007 07:40:00 8.7 1.2 11.8 6.1 8.9 1.2 11.8 6.5 8.5 1.2 11.1 5.3 80 9 95 165 1.7 0.2 1.8 1.4 02/06/2007 07:50:00 7.9 1.3 11.8 4.9 8 1.3 12.2 4.9 7.9 1.3 10.7 4.9 75 9 88 165 1.5 0.2 1.8 0.9 02/06/2007 08:00:00 8.3 1 10.7 5.3 8.5 1 11.1 5.3 8 0.9 10.3 6.1 78 8 84 165 1.7 0.2 1.8 1.1 02/06/2007 08:10:00 8.6 1.1 11.1 6.1 8.8 1.1 11.5 6.1 8.4 1 11.1 6.5 86 8 86 165 1.8 0.1 2.1 1.6 02/06/2007 08:20:00 9 0.9 11.1 6.5 9.3 0.9 11.5 7.2 8.7 0.9 11.5 6.5 84 6 86 165 1.9 0 2.1 1.6 02/06/2007 08:30:00 7.5 1.2 9.9 3.8 7.7 1.2 9.9 4.2 7.2 1.3 9.9 3.4 75 10 78 165 1.8 0.1 2.1 1.6 02/06/2007 08:40:00 7.3 1.7 10.3 4.2 7.5 1.7 10.7 4.2 6.9 1.5 10.3 3.8 73 10 94 165 1.9 0 2.1 1.6 02/06/2007 08:50:00 8 1.3 11.1 4.6 8.2 1.3 11.5 4.9 7.7 1.2 10.7 5.3 77 9 89 165 1.9 0 2.1 1.6 02/06/2007 09:00:00 7.8 1.5 11.1 4.6 8 1.6 11.8 4.9 7.5 1.3 10.7 3.8 73 12 91 165 1.8 0.2 2.3 1.4 02/06/2007 09:10:00 8.3 1.1 10.7 5.7 8.5 1.1 10.7 5.7 8 1.2 10.7 4.6 78 6 80 165 2 0 2.3 1.8 02/06/2007 09:20:00 7.3 1 9.9 4.9 7.4 1.1 10.3 4.9 7 1 9.5 4.9 65 9 64 165 1.8 0.2 2.3 1.4 02/06/2007 09:30:00 8.1 1.4 11.5 4.6 8.3 1.4 11.5 4.2 7.9 1.3 11.1 4.2 70 12 81 165 1.8 0.1 2.1 1.4 02/06/2007 09:40:00 8 1.1 11.5 4.9 8.2 1.1 11.5 5.3 7.7 1 10.3 5.7 75 8 89 165 1.8 0 2.3 1.6 02/06/2007 09:50:00 8.1 1.1 11.5 5.3 8.3 1.1 11.5 5.3 7.8 1 11.1 5.3 77 8 85 165 1.8 0.1 2.1 1.6 02/06/2007 10:00:00 9.5 1 12.6 6.8 9.7 1.1 13 7.2 9.2 1.1 12.2 6.5 80 7 78 165 1.9 0 2.1 1.6 02/06/2007 10:10:00 7.8 1 10.3 5.7 8 1 10.3 5.7 7.7 1 10.3 5.7 73 8 87 165 1.8 0.2 2.1 1.1 02/06/2007 10:20:00 8.4 1.5 11.5 4.9 8.5 1.6 11.8 4.9 8.1 1.4 11.5 4.9 77 8 75 165 1.9 0 2.1 1.6 02/06/2007 10:30:00 8.4 1.1 11.8 5.3 8.6 1.1 11.5 5.7 8.3 1.2 11.1 5.3 75 8 65 165 1.9 0 2.1 1.6 02/06/2007 10:40:00 8.2 1.3 11.8 4.6 8.4 1.4 11.8 4.9 8 1.3 11.8 4.9 63 10 66 165 1.8 0.2 2.1 1.4 02/06/2007 10:50:00 8 1.3 11.1 4.9 8.1 1.3 11.5 4.6 7.6 1.3 11.5 4.6 61 9 56 165 2 0 2.3 1.8 02/06/2007 11:00:00 6.7 1.4 10.7 3 6.8 1.4 10.3 3.4 6.5 1.4 9.9 3.4 58 11 66 165 2 0 2.3 1.8 02/06/2007 11:10:00 6 1.5 10.3 3 6.1 1.5 10.7 3 5.8 1.2 8.8 3.4 53 11 52 165 2.1 0 2.3 1.8 02/06/2007 11:20:00 7.7 1.2 11.1 5.3 7.8 1.3 11.5 4.9 7.6 1.2 11.8 4.9 67 11 70 165 1.9 0.2 2.3 1.4 02/06/2007 11:30:00 7.8 1.1 10.7 5.3 7.9 1.1 11.1 4.9 7.6 1 10.3 5.3 66 9 68 165 1.8 0.2 2.1 1.4 02/06/2007 11:40:00 6.5 1.2 10.3 4.2 6.6 1.2 10.3 4.2 6.3 1.1 9.9 3.4 57 11 72 165 1.9 0.1 2.3 1.4 02/06/2007 11:50:00 9.5 1.3 13.3 6.5 9.7 1.3 13.3 6.5 9.1 1.3 13 6.1 69 9 58 165 2.1 0 2.3 1.8 02/06/2007 12:00:00 7.3 1.2 10.7 4.2 7.4 1.2 11.1 4.2 7 1.1 10.7 4.2 62 11 68 165 2.1 0 2.3 1.8 02/06/2007 12:10:00 7.1 1.6 10.7 3.8 7.2 1.6 10.7 3.8 7 1.5 10.7 3.4 58 12 62 165 2.1 0 2.3 1.8 02/06/2007 12:20:00 7.6 1.1 10.3 4.9 7.7 1.1 10.3 4.9 7.4 1 10.7 4.9 63 9 73 165 2.1 0 2.3 1.8 02/06/2007 12:30:00 7.8 1.1 11.1 4.6 7.8 1.2 11.5 4.6 7.5 1 10.3 4.9 66 9 57 165 2.2 0 2.6 2.1 02/06/2007 12:40:00 7.5 1.7 12.2 3.8 7.6 1.8 13 3.4 7.2 1.7 12.2 4.2 61 11 77 165 2.2 0 2.6 1.8 02/06/2007 12:50:00 7.1 1 9.9 4.6 7.1 1 10.3 4.6 6.7 1 9.5 4.2 51 8 52 165 2.3 0 2.6 2.1 02/06/2007 13:00:00 7.3 1.1 9.9 4.6 7.3 1.1 10.3 4.2 7.1 1.1 9.5 4.2 57 9 68 165 2.1 0.1 2.3 1.6 02/06/2007 13:10:00 7.9 1.1 11.1 5.3 7.9 1.2 11.5 5.3 7.5 1.1 11.1 4.9 51 9 56 165 2.1 0.1 2.3 1.8 02/06/2007 13:20:00 7.5 1.3 11.1 4.9 7.5 1.5 11.1 4.6 7.4 1.3 11.1 4.9 59 10 52 165 2.1 0.1 2.6 1.6 02/06/2007 13:30:00 7 1.4 10.7 3.8 7 1.4 10.7 3.4 6.8 1.3 10.3 4.2 50 9 56 165 2.4 0 2.6 2.3 02/06/2007 13:40:00 6.6 1.5 10.7 3.8 6.7 1.5 11.5 3.8 6.4 1.3 10.3 4.2 49 11 57 165 2.4 0 2.6 2.3 02/06/2007 13:50:00 10.4 1.3 13.7 6.8 10.5 1.4 13.7 6.8 10.2 1.4 13.3 6.1 59 8 57 165 2.1 0 2.6 1.8 02/06/2007 14:00:00 8.9 1.3 12.2 5.3 8.9 1.4 12.6 5.7 8.6 1.2 11.8 5.3 52 8 58 165 2.1 0 2.3 2.1 02/06/2007 14:10:00 8.4 1.3 12.2 4.9 8.4 1.4 11.8 5.3 8.2 1.3 11.8 4.9 53 8 65 165 2.1 0.1 2.6 1.6 02/06/2007 14:20:00 8.6 1.4 12.2 4.9 8.6 1.5 12.2 4.9 8.4 1.3 11.8 4.9 49 9 53 165 2.1 0.1 2.3 1.4 02/06/2007 14:30:00 8.7 1.2 12.6 6.1 8.7 1.2 12.6 6.1 8.3 1.3 11.8 5.3 49 8 54 165 1.9 0.2 2.3 1.4 02/06/2007 14:40:00 9 1.3 12.6 5.3 9 1.4 12.6 4.9 8.7 1.3 12.2 4.6 52 8 50 165 2 0.2 2.3 1.4 02/06/2007 14:50:00 9 1.2 12.6 5.3 9.1 1.3 12.6 5.7 8.7 1.1 13 5.7 54 8 56 165 2 0.2 2.3 1.4 02/06/2007 15:00:00 8.6 1.3 11.8 5.3 8.6 1.3 12.2 5.3 8.2 1.2 11.8 5.3 58 8 64 165 2 0.1 2.3 1.4 02/06/2007 15:10:00 8.9 1.5 12.2 4.9 8.8 1.5 12.2 4.9 8.4 1.5 12.6 4.6 54 9 47 165 1.8 0.2 2.3 1.4 02/06/2007 15:20:00 9.2 1.5 13.7 6.1 9.2 1.5 14.1 5.7 8.9 1.3 12.6 5.7 52 9 58 165 2 0.1 2.3 1.4 02/06/2007 15:30:00 9.9 1.3 13.3 5.7 10 1.4 13.7 6.5 9.4 1.2 13 6.1 56 9 59 165 2.1 0.1 2.3 1.6 02/06/2007 15:40:00 10.1 1.7 13.7 6.1 10.2 1.7 13.7 5.7 9.4 1.6 13.3 5.7 51 9 51 165 2.3 0.1 2.6 1.8 02/06/2007 15:50:00 9 1.5 13 4.6 9 1.5 13.3 4.6 8.5 1.5 12.6 5.3 50 11 52 165 2.3 0.1 2.6 1.8 02/06/2007 16:00:00 9.4 1.3 12.6 6.1 9.5 1.3 12.6 6.1 9.1 1.3 12.6 6.1 49 9 49 165 2.3 0.1 2.6 1.8 02/06/2007 16:10:00 10.1 1.4 14.5 6.8 10.1 1.5 14.9 6.8 9.6 1.3 13.7 6.5 49 9 56 165 2.3 0.1 2.6 1.8 02/06/2007 16:20:00 10.7 1.7 14.9 6.5 10.7 1.8 14.9 6.1 10.4 1.8 15.6 6.1 49 9 49 165 2.3 0.1 2.6 1.8 02/06/2007 16:30:00 9.8 1.7 13.3 5.7 9.8 1.7 13.3 5.7 9.3 1.5 13.3 5.7 49 8 63 165 2.1 0.2 2.6 1.6 02/06/2007 16:40:00 10.6 1.5 14.5 6.1 10.6 1.6 14.5 6.5 10 1.5 13.7 6.8 49 8 63 165 2 0.1 2.3 1.4 02/06/2007 16:50:00 10.4 1.5 14.5 6.8 10.4 1.6 14.5 6.5 9.9 1.4 13.3 6.5 48 9 43 165 2.1 0 2.3 1.8 02/06/2007 17:00:00 9.3 1.3 13.7 6.1 9.4 1.4 14.1 6.1 8.9 1.3 13 5.7 46 10 52 165 2 0 2.3 1.8 02/06/2007 17:10:00 10.3 1.5 14.1 6.8 10.4 1.5 14.5 6.8 10 1.3 13 6.5 43 9 41 165 2 0.1 2.3 1.4 02/06/2007 17:20:00 10.6 1.3 13.7 6.8 10.6 1.4 13.7 6.5 10.4 1.3 13.7 6.8 40 8 48 165 2 0.2 2.3 1.4 02/06/2007 17:30:00 10.3 1.7 13.7 6.5 10.2 1.7 13.7 6.5 10.1 1.5 13.7 6.1 43 9 40 165 2 0.2 2.6 1.4 02/06/2007 17:40:00 10.8 1.7 15.6 6.5 10.8 1.7 16.1 6.8 10.6 1.5 14.9 6.8 42 8 43 165 2.1 0.1 2.6 1.6 02/06/2007 17:50:00 10.8 1.6 14.9 7.2 10.8 1.6 15.3 7.2 10.4 1.3 14.1 6.1 40 9 37 165 2 0.2 2.3 1.4 02/06/2007 18:00:00 11.8 1.7 16.1 8.8 11.7 1.7 16.1 8.4 11.6 1.7 15.3 8 33 8 41 165 2 0.1 2.3 1.4 02/06/2007 18:10:00 11.7 1.5 16.1 7.6 11.6 1.5 16.1 7.6 11.8 1.7 16.4 8 34 8 37 165 2 0.2 2.3 1.4 02/06/2007 18:20:00 11.8 1.6 16.1 8 11.7 1.6 15.6 8 11.8 1.6 15.6 8.4 35 7 43 165 2 0.1 2.3 1.4 02/06/2007 18:30:00 11.8 1.5 16.4 8.8 11.7 1.5 16.1 8.4 11.6 1.7 16.1 8 36 6 36 165 1.9 0.2 2.3 1.4 02/06/2007 18:40:00 12.6 1.3 15.6 8.8 12.5 1.3 15.6 8.4 12.4 1.3 15.3 8.4 36 8 31 165 2 0.1 2.3 1.4 02/06/2007 18:50:00 12.5 2 16.8 8 12.3 2 16.4 7.6 12.2 2.1 17.2 8 34 8 40 165 2 0 2.3 1.4 02/06/2007 19:00:00 12.9 1.7 17.2 8.4 12.8 1.8 17.2 8 12.9 1.7 16.8 8.8 34 7 43 165 1.9 0.1 2.3 1.4 02/06/2007 19:10:00 13.3 1.8 17.2 7.2 13.2 1.9 17.2 6.8 12.9 1.8 17.6 7.6 33 7 37 165 2 0.1 2.3 1.4 02/06/2007 19:20:00 12.1 1.6 16.1 8.8 11.9 1.7 16.1 8 11.8 1.7 16.4 8 31 8 28 165 2.1 0.1 2.6 1.4 02/06/2007 19:30:00 12.8 1.6 17.2 7.6 12.6 1.7 16.8 7.6 12.5 1.7 16.1 8 30 7 35 165 2.1 0 2.3 1.6 02/06/2007 19:40:00 12.6 1.5 16.1 8.8 12.4 1.6 16.1 8 12.4 1.6 16.8 8.8 31 8 36 165 2 0.1 2.3 1.4 02/06/2007 19:50:00 12.7 1.5 17.9 9.5 12.5 1.6 16.8 8.8 12.4 1.6 16.4 8.4 32 7 28 165 1.8 0.2 2.3 1.4 02/06/2007 20:00:00 12.5 1.2 15.3 8.8 12.3 1.3 15.3 8.8 12.3 1.2 16.1 7.6 35 7 37 165 1.8 0.1 2.1 1.4 02/06/2007 20:10:00 12.2 1.5 15.3 7.2 12 1.5 14.9 7.2 11.9 1.7 16.1 7.2 32 8 29 165 1.7 0.2 1.8 1.4 02/06/2007 20:20:00 13 1.7 16.1 7.2 12.9 1.8 16.1 7.2 13 1.9 16.4 8.4 32 7 39 165 1.7 0.2 1.8 1.1 02/06/2007 20:30:00 11.8 1.3 15.6 8 11.6 1.5 15.3 7.6 11.7 1.5 16.1 7.6 25 8 28 165 1.7 0.2 2.1 1.4 02/06/2007 20:40:00 12.6 1.5 17.9 9.1 12.5 1.6 17.6 9.1 12.5 1.7 17.6 8.8 31 7 37 165 1.8 0.2 2.1 1.4 02/06/2007 20:50:00 11.3 1.2 15.3 8.4 11.2 1.3 15.6 7.6 11.4 1.3 14.5 8 34 5 46 165 1.7 0.1 1.8 1.4 02/06/2007 21:00:00 13.4 1.7 16.4 8.4 13.3 1.8 16.4 8 13.4 2 16.8 8 29 7 22 165 1.6 0 1.8 1.4 02/06/2007 21:10:00 13.3 1.4 15.6 8 13.1 1.5 16.1 6.8 13 1.5 16.4 8.4 26 6 20 165 1.5 0 1.8 1.1 02/06/2007 21:20:00 13.4 1.2 16.1 9.5 13.3 1.3 16.1 9.1 13.3 1.4 16.8 9.9 26 6 32 165 1.4 0.1 1.8 0.9 02/06/2007 21:30:00 12.7 1.4 15.3 8 12.4 1.7 15.3 6.1 12.7 1.5 15.6 7.6 22 7 23 165 1.4 0.1 1.8 0.9 02/06/2007 21:40:00 12.4 1.6 15.6 8.8 12.1 1.7 15.6 7.2 12.3 1.6 16.1 8.4 23 8 28 165 1.5 0 1.8 1.4 02/06/2007 21:50:00 13 1.3 15.6 9.1 12.6 1.5 15.6 8.8 12.9 1.5 16.4 9.1 21 6 29 165 1.5 0 1.6 1.4 02/06/2007 22:00:00 11.3 1.3 13.7 7.2 10.9 1.4 13.7 6.5 11.5 1.3 14.5 7.6 20 7 20 165 1.5 0 1.8 1.4 02/06/2007 22:10:00 12.2 1.7 15.6 8.4 11.8 1.8 15.3 6.1 12.3 1.7 16.1 8.4 22 8 18 165 1.5 0 1.8 1.4 02/06/2007 22:20:00 12.9 1.6 16.1 8 12.5 1.8 16.1 7.2 12.8 1.7 16.4 7.6 23 8 30 165 1.5 0 1.8 1.4 02/06/2007 22:30:00 13.9 1.4 17.2 9.9 13.6 1.5 16.8 8.8 13.9 1.7 17.9 9.5 26 6 31 165 1.7 0 1.8 1.4 02/06/2007 22:40:00 12.8 1.7 17.2 7.6 12.3 2 16.8 6.5 12.9 2 17.6 7.2 23 8 32 165 1.7 0 1.8 1.1 02/06/2007 22:50:00 12.1 1.5 16.4 8.4 11.4 1.7 16.1 7.6 12.1 1.5 15.6 9.1 20 8 19 165 1.8 0 1.8 1.6 02/06/2007 23:00:00 14.2 1.9 17.9 9.5 13.8 2.1 17.6 8.4 13.7 2 18.3 9.5 23 8 31 165 1.8 0 1.8 1.6 02/06/2007 23:10:00 13.5 1.7 17.6 9.1 13.1 1.8 17.2 8.4 13.2 1.7 17.2 8.8 20 8 25 165 1.8 0 1.8 1.6 02/06/2007 23:20:00 13.6 1.7 16.8 8.8 13.1 1.8 16.8 8 13.3 1.7 17.2 8.8 21 8 22 165 1.8 0 1.8 1.4 02/06/2007 23:30:00 13.5 1.4 17.2 9.5 12.8 1.7 16.8 7.2 13.1 1.5 17.2 9.1 18 8 25 165 1.8 0 1.8 1.6 02/06/2007 23:40:00 12.9 1.5 16.1 8.8 12.4 1.7 16.1 7.6 12.5 1.5 16.1 8.8 19 7 18 165 1.9 0 2.1 1.8 02/06/2007 23:50:00 12.9 1.2 15.3 9.5 12 1.5 15.3 8 12.6 1.2 15.6 9.1 16 7 18 165 1.9 0 2.3 1.8 02/07/2007 00:00:00 12.9 1.3 15.6 9.5 11.8 1.7 15.3 6.5 12.6 1.4 16.1 8.8 15 7 16 165 1.9 0 2.3 1.8 02/07/2007 00:10:00 13.2 1.1 15.6 9.5 12.4 1.7 15.6 7.6 12.5 1.2 16.1 9.1 19 7 26 165 1.9 0 2.1 1.6 02/07/2007 00:20:00 13 1.6 16.8 8.4 11.9 2 16.1 7.2 12.7 1.5 16.4 9.5 16 7 18 165 1.9 0 2.3 1.8 02/07/2007 00:30:00 13.3 1.5 16.4 8.8 11.8 1.9 16.1 7.2 12.7 1.4 15.6 9.5 15 7 357 165 1.9 0 2.3 1.8 02/07/2007 00:40:00 11.8 1.5 16.4 8.4 10.5 2.1 15.6 5.7 11.6 1.7 16.4 8.4 14 7 19 165 1.8 0 1.8 1.6 02/07/2007 00:50:00 13.2 1.3 16.4 9.5 12 1.7 16.4 7.6 12.9 1.5 17.2 9.5 15 7 22 165 1.9 0 2.1 1.4 02/07/2007 01:00:00 13.3 1.6 17.2 9.5 12 2 16.8 7.6 13.1 1.6 17.6 9.9 15 7 25 165 1.9 0 2.3 1.8 02/07/2007 01:10:00 13 1.4 17.9 9.5 11.4 1.7 17.6 7.2 12.8 1.5 17.6 9.1 13 7 19 165 2 0 2.3 1.8 02/07/2007 01:20:00 11.8 1.1 14.9 8.8 10.3 1.6 14.1 5.7 11.4 1.3 14.5 8 12 8 26 165 2.1 0 2.3 1.8 02/07/2007 01:30:00 12.6 1.2 15.6 8.4 10.6 1.7 14.9 5.3 12.3 1.3 15.3 8 10 6 12 165 2.1 0 2.3 1.8 02/07/2007 01:40:00 12.4 1.5 15.6 8.8 10.3 1.7 15.6 6.1 12.3 1.5 16.4 8.4 10 6 5 165 2.1 0 2.3 1.8 02/07/2007 01:50:00 12.4 1.1 15.3 9.5 10.1 1.6 13.7 6.1 12.2 1.1 15.3 9.5 8 7 9 165 2.1 0 2.3 1.8 02/07/2007 02:00:00 12.4 1.1 15.6 8.8 9.9 1.8 15.6 5.3 12.1 1.1 15.6 9.9 7 7 22 165 2.1 0 2.3 2.1 02/07/2007 02:10:00 13.1 1.3 16.1 9.9 10.2 1.7 15.3 6.5 13 1.3 16.1 9.9 6 6 4 165 2.2 0 2.6 2.1 02/07/2007 02:20:00 12.9 1.3 15.6 8.4 10.4 1.8 14.9 5.7 12.9 1.3 15.6 9.1 6 7 11 165 2.2 0 2.3 1.8 02/07/2007 02:30:00 12.3 1.1 14.9 9.5 9.9 1.5 13.7 6.5 12.1 1.3 15.6 9.1 5 8 10 165 2.2 0 2.6 1.8 02/07/2007 02:40:00 11.8 1.3 16.1 8.8 9.3 1.5 15.3 6.5 11.8 1.4 15.6 8.4 5 7 10 165 2.3 0 2.6 2.1 02/07/2007 02:50:00 12.4 1.5 16.1 9.1 10.1 1.7 15.6 6.1 12.3 1.3 15.6 9.1 5 7 15 165 2.3 0 2.6 1.8 02/07/2007 03:00:00 12.7 1.5 17.2 9.1 10.9 1.9 16.8 6.1 12.5 1.5 17.9 9.5 8 7 12 165 2.4 0 2.6 2.1 02/07/2007 03:10:00 11.4 1.3 14.9 8.8 9.6 1.7 13.3 5.7 11.5 1.2 14.9 9.1 8 8 357 165 2.4 0 2.6 2.1 02/07/2007 03:20:00 12.6 1.3 16.4 9.1 10.4 1.6 14.1 6.5 12.3 1.2 15.6 9.5 7 8 358 165 2.4 0 2.6 2.1 02/07/2007 03:30:00 13.2 1.5 16.8 9.5 10.5 1.7 14.5 6.8 12.7 1.7 16.4 8 5 8 5 165 2.4 0 2.6 1.8 02/07/2007 03:40:00 13.2 1.5 16.4 9.1 10.5 1.6 14.1 6.5 13.1 1.5 16.4 9.5 5 7 3 165 2.4 0 2.6 1.8 02/07/2007 03:50:00 13.7 1.2 17.2 10.7 11.1 1.6 16.4 7.6 13.3 1.3 16.8 9.9 5 8 7 165 2.3 0 2.6 1.8 02/07/2007 04:00:00 13.5 1.7 17.2 9.9 10.5 1.8 15.6 6.1 13.4 1.7 17.2 9.5 4 7 15 165 2.3 0 2.6 2.1 02/07/2007 04:10:00 13.3 1.7 17.9 9.5 10.2 1.7 15.3 5.7 13.1 1.6 17.2 9.5 4 6 2 165 2.3 0 2.6 2.1 02/07/2007 04:20:00 13.4 1.5 17.6 9.9 9.9 1.5 15.3 6.1 13.3 1.6 17.6 9.1 1 6 354 165 2.3 0 2.6 2.1 02/07/2007 04:30:00 12.5 1.7 16.8 8.4 9.4 1.9 14.9 4.9 12.4 1.7 16.8 8.4 3 8 17 165 2.3 0 2.6 2.1 02/07/2007 04:40:00 12.3 1.7 16.8 7.6 9.4 2 16.1 5.7 12.2 1.8 16.4 6.8 1 10 25 165 2.3 0 2.6 2.3 02/07/2007 04:50:00 11.7 1.6 15.6 8 9.1 1.8 14.9 5.3 11.6 1.5 16.1 8 1 9 5 165 2.4 0 2.6 2.3 02/07/2007 05:00:00 11.4 1.4 15.6 7.6 8.6 1.6 15.3 5.3 11.2 1.5 15.3 7.6 2 8 13 165 2.4 0 2.6 2.3 02/07/2007 05:10:00 12.3 1.7 17.9 8 9.6 1.7 14.5 5.7 12.3 1.7 17.9 8.4 3 8 5 165 2.4 0.1 2.8 2.1 02/07/2007 05:20:00 11.7 1.3 15.6 8.4 9.2 1.7 14.9 5.3 11.6 1.4 15.3 8 1 9 355 165 2.4 0.1 2.8 1.8 02/07/2007 05:30:00 11.9 1.9 16.8 6.8 9 2 14.5 4.2 11.8 1.7 16.8 7.2 1 8 3 165 2.6 0 2.8 2.3 02/07/2007 05:40:00 11.3 1.4 16.1 8.4 8.9 1.7 16.4 5.7 11.2 1.4 15.3 8.4 1 10 1 165 2.6 0 2.8 2.1 02/07/2007 05:50:00 11.4 1.6 16.1 6.8 8.8 1.7 15.3 4.6 11.2 1.5 15.6 7.2 359 8 354 165 2.6 0 2.8 2.6 02/07/2007 06:00:00 11.3 1.6 15.3 7.2 8.9 1.8 14.5 3.8 11.2 1.7 15.6 6.1 360 10 339 165 2.7 0 2.8 2.6 02/07/2007 06:10:00 11 1.7 15.6 7.6 8.3 1.7 14.9 4.9 10.9 1.7 16.1 7.2 360 7 352 165 2.7 0 2.8 2.3 02/07/2007 06:20:00 11.8 1.7 16.4 8 9.3 2 14.9 6.1 11.5 1.7 16.8 8 0 9 4 165 2.7 0 2.8 2.6 02/07/2007 06:30:00 10.6 1.5 14.5 6.8 9 1.9 14.9 5.7 10.3 1.5 14.1 6.8 359 11 12 165 2.7 0 3 2.1 02/07/2007 06:40:00 10.9 1.3 14.9 7.6 8.8 2 14.1 5.3 10.8 1.4 14.5 6.8 358 9 7 165 2.8 0 3 2.1 02/07/2007 06:50:00 11.5 1.7 15.6 7.2 9.4 1.8 15.3 4.9 11.2 1.6 14.9 6.5 358 9 5 165 2.8 0 3 2.1 02/07/2007 07:00:00 11.1 1.6 15.6 8 8.8 1.7 16.1 5.3 10.9 1.6 15.6 7.2 358 9 341 165 2.8 0 3 2.1 02/07/2007 07:10:00 11.5 1.7 15.3 7.6 9.4 2.2 14.9 4.9 11.2 1.7 16.1 7.6 355 7 358 165 2.8 0 3 2.1 02/07/2007 07:20:00 11.3 2 16.8 6.8 9.3 2.2 14.9 4.6 10.9 1.9 15.3 6.8 356 9 6 165 2.8 0 3 2.6 02/07/2007 07:30:00 11.6 1.7 16.1 7.2 9.3 2.1 16.4 5.3 11.2 1.8 16.1 6.5 355 7 349 165 2.9 0 3 2.3 02/07/2007 07:40:00 10.4 1.4 14.5 6.8 8.2 1.6 13 4.6 10.2 1.5 14.1 6.1 357 8 355 165 2.9 0 3 2.3 02/07/2007 07:50:00 10.6 1.5 14.9 6.5 8.5 2.2 14.9 4.9 10.4 1.5 14.1 6.1 356 8 350 165 2.9 0.1 3 2.3 02/07/2007 08:00:00 9.1 1.5 13.3 5.7 7.2 1.6 11.5 3.4 8.8 1.5 12.6 5.7 360 9 360 165 2.9 0.1 3.3 2.1 02/07/2007 08:10:00 9.8 1.7 13.7 5.7 7.7 1.9 13.3 3.8 9.6 1.7 13.7 4.9 357 9 356 165 2.9 0 3.3 2.6 02/07/2007 08:20:00 10.3 1.5 13.7 6.1 8 1.7 13.3 3.4 10.1 1.5 13.7 6.5 358 7 357 165 2.9 0.1 3.3 2.3 02/07/2007 08:30:00 9.9 1.5 14.9 6.1 7.7 1.6 13.3 4.6 9.6 1.6 14.1 6.5 360 9 6 165 3 0.1 3.3 2.6 02/07/2007 08:40:00 9.2 1.5 13.7 6.1 7.3 1.6 11.1 4.2 9 1.5 12.2 5.7 0 9 357 165 3 0 3.3 2.8 02/07/2007 08:50:00 9.9 1.5 13.7 5.3 7.7 1.7 11.5 3.8 9.8 1.4 13 5.3 4 9 9 165 3 0 3.3 2.8 02/07/2007 09:00:00 9.1 1.4 13.7 6.1 7.1 1.5 12.6 3.4 9 1.3 13 5.7 2 9 20 165 3 0 3.3 2.8 02/07/2007 09:10:00 9.7 1.7 13.3 5.7 7.7 1.7 11.8 4.2 9.6 1.7 13.7 6.1 5 9 9 165 3 0 3.3 2.8 02/07/2007 09:20:00 9.3 1.4 13 6.5 7.2 1.5 11.5 3.8 9.1 1.3 12.6 6.5 4 9 352 165 3.1 0 3.3 2.6 02/07/2007 09:30:00 10.4 1.2 13.7 6.1 8.2 1.7 13 3.8 10 1.2 13.3 6.5 9 8 12 165 3.1 0 3.5 2.6 02/07/2007 09:40:00 9.8 1 12.6 7.2 7.6 1.5 11.5 4.6 9.6 1 13 7.2 8 7 5 165 3.1 0 3.3 2.6 02/07/2007 09:50:00 10 1.3 13.3 6.5 7.7 1.6 12.6 3.8 9.8 1.3 13.3 6.5 8 8 11 165 3.2 0 3.5 2.6 02/07/2007 10:00:00 10.4 1.2 13.3 7.2 8 1.4 11.8 4.6 10.2 1.3 13 7.2 8 7 7 165 3.2 0 3.5 2.6 02/07/2007 10:10:00 9.7 1.3 12.2 6.8 7.5 1.3 10.7 4.9 9.7 1.2 12.2 7.2 7 7 7 165 3.2 0 3.5 2.8 02/07/2007 10:20:00 9.9 1 12.2 7.6 7.7 1.2 11.8 4.9 9.9 1 12.2 8 8 7 12 165 3.2 0 3.5 2.8 02/07/2007 10:30:00 9.6 1 12.2 7.2 7.5 1.3 11.5 4.6 9.3 1.1 12.6 6.1 8 7 7 165 3.2 0 3.5 2.8 02/07/2007 10:40:00 9.9 1.2 13 6.8 7.5 1.5 11.5 3.8 10 1.2 12.6 6.8 7 6 15 165 3.3 0 3.5 2.8 02/07/2007 10:50:00 9 1.2 12.2 6.1 6.6 1.2 9.5 3.8 8.9 1.1 12.2 6.1 4 7 14 165 3.3 0 3.5 3 02/07/2007 11:00:00 9.3 1 11.8 6.1 7.3 1.3 10.7 4.6 9 1 11.5 6.1 8 8 7 165 3.3 0 3.5 3.3 02/07/2007 11:10:00 9.3 1.3 13 6.1 7.2 1.6 12.6 3.8 9 1.4 12.6 6.1 7 7 22 165 3.4 0 3.5 3.3 02/07/2007 11:20:00 9.2 1 11.8 6.8 7.1 1.5 11.1 4.2 9 1.1 11.8 6.1 8 7 10 165 3.4 0 3.8 3 02/07/2007 11:30:00 8.6 1 11.5 6.1 6.6 1.1 9.5 4.2 8.5 1 11.5 6.5 8 7 6 165 3.5 0 3.5 3.3 02/07/2007 11:40:00 8.1 1 10.3 5.7 6.4 1.2 9.5 3.8 7.8 1 10.3 5.7 9 7 9 165 3.5 0 4 3.3 02/07/2007 11:50:00 8.8 0.9 11.1 6.5 6.7 1.2 9.9 3.8 8.4 1 11.1 5.7 8 7 10 165 3.5 0 3.5 3.3 02/07/2007 12:00:00 8.3 1.1 11.5 5.3 6.6 1.2 10.7 3.4 8.1 1 10.7 5.3 10 6 11 165 3.5 0 3.8 3.3 02/07/2007 12:10:00 8 1 10.7 5.3 6.3 1.2 9.5 3.4 7.8 1 10.7 4.9 8 8 11 165 3.5 0 4.3 3.5 02/07/2007 12:20:00 8.6 0.9 10.7 5.7 6.7 1.1 9.9 4.2 8.5 0.9 11.1 6.1 9 7 10 165 3.5 0 3.8 3.5 02/07/2007 12:30:00 8.1 1.3 11.1 4.6 6.2 1.3 9.9 2.3 7.9 1.3 10.7 4.9 8 7 8 165 3.5 0 3.8 3.5 02/07/2007 12:40:00 8.1 0.9 10.3 5.7 6 1.3 9.5 3.4 8 1 10.3 5.3 6 8 360 165 3.6 0 3.8 3.5 02/07/2007 12:50:00 7.7 0.9 9.5 5.3 5.9 1.1 8.8 3 7.5 0.9 9.5 4.9 8 7 18 165 3.6 0 4 3.5 02/07/2007 13:00:00 7.7 1.1 10.3 4.9 5.6 1.3 9.1 2.6 7.6 1.1 10.7 5.3 7 6 15 165 3.6 0 3.8 3.5 02/07/2007 13:10:00 7.9 1.3 11.1 4.9 6 1.3 9.9 3 7.7 1.3 11.5 4.2 7 6 4 165 3.6 0 3.8 3.5 02/07/2007 13:20:00 8.4 1.4 11.5 5.3 6.4 1.5 10.3 3.4 8.2 1.3 11.1 5.3 5 8 5 165 3.6 0 3.8 3.3 02/07/2007 13:30:00 8.7 1 12.6 6.5 6.7 1.3 11.8 3.4 8.5 1.1 12.2 5.7 7 7 12 165 3.6 0 3.8 3.3 02/07/2007 13:40:00 8.8 1 11.5 5.7 6.8 1.3 10.3 4.2 8.6 1.1 11.1 6.1 7 6 1 165 3.6 0 3.8 3.3 02/07/2007 13:50:00 8.7 1 10.7 6.1 6.6 1.3 10.3 3.8 8.4 0.9 10.7 5.7 6 7 15 165 3.6 0 3.8 3.3 02/07/2007 14:00:00 8.6 1.3 12.2 5.3 6.7 1.5 11.5 3.4 8.3 1.3 12.2 4.6 8 7 5 165 3.6 0 3.8 3.3 02/07/2007 14:10:00 7.9 1 11.1 5.7 5.7 1.1 9.5 3.4 7.8 1 10.7 5.3 3 8 14 165 3.5 0.1 3.8 3.3 02/07/2007 14:20:00 8.3 1.3 11.8 4.9 6.4 1.5 9.9 3 8.2 1.3 11.1 5.3 7 7 11 165 3.5 0.1 3.8 3 02/07/2007 14:30:00 9.6 1 11.8 6.8 7.4 1.4 11.1 4.2 9.4 1.1 11.8 6.8 9 5 11 165 3.5 0.1 3.8 3 02/07/2007 14:40:00 9.4 1.1 12.2 6.5 7.2 1.5 11.5 3.8 9.1 1.1 11.5 6.5 7 6 16 165 3.5 0.1 3.8 3 02/07/2007 14:50:00 8.2 1.1 10.7 4.9 6.1 1.2 9.1 3 8.1 1.2 11.8 4.6 6 7 12 165 3.5 0.1 3.5 3 02/07/2007 15:00:00 9.4 1 11.8 6.1 7.3 1.5 11.8 4.2 9.2 1 12.2 6.1 8 7 20 165 3.5 0.1 3.5 3 02/07/2007 15:10:00 9 0.9 11.5 6.5 7 1.2 10.3 4.2 9 1 11.5 6.1 8 7 5 165 3.5 0 3.5 3 02/07/2007 15:20:00 9.5 1.1 12.2 7.2 7.4 1.3 11.5 4.6 9.4 1 12.6 7.2 8 6 12 165 3.5 0 3.5 3.3 02/07/2007 15:30:00 9.3 1.3 12.6 5.3 7.5 1.6 11.8 3.8 9.2 1.3 12.2 5.7 11 7 14 165 3.5 0 4 3.3 02/07/2007 15:40:00 9.3 0.8 11.5 6.5 7.3 1.2 10.7 4.9 9.1 0.9 11.5 6.5 10 7 13 165 3.5 0 3.8 3.3 02/07/2007 15:50:00 8.3 1.3 11.8 5.3 6.5 1.5 10.7 2.6 8.1 1.3 11.1 5.3 8 8 18 165 3.4 0 3.8 3.3 02/07/2007 16:00:00 9.6 0.9 12.2 6.8 7.4 1.5 11.5 4.6 9.4 1.1 11.8 6.5 8 6 14 165 3.4 0 3.5 3.3 02/07/2007 16:10:00 8.9 1.2 11.8 6.1 6.7 1.7 11.5 3.4 8.7 1.1 11.5 5.7 7 7 6 165 3.4 0 3.8 3.3 02/07/2007 16:20:00 8 1.1 10.7 5.3 6 1.2 9.1 3.4 7.9 1.1 11.1 5.3 5 8 6 165 3.3 0 3.5 3.3 02/07/2007 16:30:00 7.6 0.8 9.9 5.3 5.6 1.3 9.1 3.8 7.3 0.9 9.5 4.6 5 10 10 165 3.3 0 3.5 3 02/07/2007 16:40:00 7.6 1.2 10.7 4.9 5.4 1.3 8.8 2.6 7.3 1.1 9.9 4.9 2 7 354 165 3.2 0 3.8 2.8 02/07/2007 16:50:00 8 1.1 10.7 5.3 5.7 1.5 9.9 2.6 7.9 1 11.1 6.1 5 7 14 165 3.3 0 3.5 3 02/07/2007 17:00:00 8.1 1.3 11.1 5.3 5.9 1.5 10.3 3 8.1 1.3 11.1 5.3 4 7 7 165 3.3 0 3.5 3 02/07/2007 17:10:00 7.5 1.1 10.3 4.9 5.3 1.2 9.1 3 7.3 1.1 10.3 4.9 3 7 6 165 3.2 0 3.5 3 02/07/2007 17:20:00 8.3 1.2 11.5 5.3 6.1 1.4 9.9 3.8 8.1 1.3 11.1 5.3 8 6 3 165 3.2 0 3.5 3 02/07/2007 17:30:00 8.1 0.9 10.7 6.5 6.2 1.2 9.5 3.8 7.8 1 10.7 5.7 7 7 8 165 3.2 0 3.5 2.8 02/07/2007 17:40:00 7.9 1.1 10.7 5.3 6.1 1.5 9.9 3 7.6 1.1 10.3 5.3 7 6 19 165 3.2 0 3.3 3 02/07/2007 17:50:00 7.7 1 9.9 5.3 5.8 1.3 9.9 3 7.3 1 9.9 5.3 5 8 20 165 3.2 0 3.3 3 02/07/2007 18:00:00 8 1.1 11.1 5.7 5.9 1.5 10.3 3 7.9 1.1 11.5 6.1 6 7 7 165 3.2 0 3.5 2.6 02/07/2007 18:10:00 7.5 0.8 9.5 5.3 5.5 1 7.6 3 7.3 0.9 9.5 5.3 6 6 360 165 3.2 0 3.5 2.8 02/07/2007 18:20:00 7.6 0.8 9.5 5.3 5.6 1.2 9.1 3 7.5 0.7 9.5 4.9 6 7 15 165 3.2 0 3.5 2.6 02/07/2007 18:30:00 7.4 0.8 9.5 4.9 5.4 1 7.6 3 7.2 0.8 9.1 5.3 6 6 11 165 3.2 0 3.5 2.8 02/07/2007 18:40:00 7 0.8 9.1 4.9 5.1 1.1 7.6 2.6 6.8 0.8 8.8 4.6 6 7 5 165 3.2 0 3.8 2.6 02/07/2007 18:50:00 7 0.9 8.8 4.6 5 1.1 8 2.6 6.8 0.8 8.8 4.9 7 5 14 165 3.2 0 3.5 2.8 02/07/2007 19:00:00 6.4 0.7 8 4.2 4.7 0.9 7.6 2.6 6.3 0.7 8.4 4.2 8 5 11 165 3.2 0 3.3 2.6 02/07/2007 19:10:00 6.6 0.9 8.8 4.2 5 1 7.6 2.6 6.5 1 8.8 4.6 8 7 360 165 3.2 0 3.5 2.6 02/07/2007 19:20:00 6.2 0.7 7.6 4.6 4.6 1 7.2 2.6 6.1 0.7 7.6 4.6 8 6 10 165 3.2 0 3.3 2.8 02/07/2007 19:30:00 4.8 0.5 6.5 3.4 3.2 0.8 5.7 1.5 4.8 0.5 6.1 3.4 3 6 5 165 3.1 0 3.5 2.8 02/07/2007 19:40:00 4.6 0.5 5.7 3.4 3.5 0.9 5.3 1.1 4.6 0.6 5.7 3 6 7 16 165 3.1 0.1 3.3 2.6 02/07/2007 19:50:00 4.1 0.5 5.7 3 2.5 0.7 4.6 0.7 3.9 0.4 5.3 3 359 6 357 165 3 0 3.3 2.8 02/07/2007 20:00:00 3.8 0.4 4.9 2.6 2.7 0.8 4.6 1.1 3.7 0.3 4.9 3 352 6 356 165 2.8 0 3 2.3 02/07/2007 20:10:00 4.2 0.5 5.7 3 4 0.8 5.3 1.5 4.2 0.5 5.7 3.4 345 6 352 165 2.7 0 2.8 2.6 02/07/2007 20:20:00 4 0.4 5.3 3 3.7 0.6 4.9 1.9 3.8 0.4 4.9 3 345 5 340 165 2.6 0 2.8 2.6 02/07/2007 20:30:00 4.3 0.5 5.3 3 4.1 0.6 5.3 1.9 4.2 0.4 5.3 3 344 6 342 165 2.6 0 2.8 2.6 02/07/2007 20:40:00 4 0.5 5.7 3 3.8 0.6 5.7 2.3 3.8 0.6 5.3 2.3 346 5 349 165 2.6 0 2.8 2.6 02/07/2007 20:50:00 4 0.4 4.9 3 3.6 0.6 4.6 1.5 3.8 0.4 4.9 2.6 347 4 347 165 2.6 0 2.8 2.3 02/07/2007 21:00:00 3.7 0.3 4.6 2.3 2.6 0.8 4.2 1.1 3.7 0.3 4.6 2.6 351 6 345 165 2.6 0 2.8 2.6 02/07/2007 21:10:00 3.3 0.5 4.2 2.3 2.1 0.7 3.4 0.7 3.1 0.5 4.2 1.5 353 5 350 165 2.6 0 2.8 2.3 02/07/2007 21:20:00 3 0.4 4.2 1.9 1.7 0.6 3.4 0.4 3 0.5 4.2 1.5 355 5 354 165 2.6 0 2.8 2.1 02/07/2007 21:30:00 3.6 0.6 4.6 1.5 3.1 0.8 4.2 0.7 3.3 0.6 4.6 1.1 15 6 19 165 2.8 0.1 3 2.3 02/07/2007 21:40:00 3.8 0.4 4.9 2.6 3.6 0.4 4.6 2.6 3.7 0.4 4.9 2.6 18 3 18 165 3 0 3.3 2.8 02/07/2007 21:50:00 3.5 0.3 4.2 3 3.4 0.3 4.2 2.3 3.5 0.3 4.2 2.6 23 4 16 165 3 0 3.3 2.8 02/07/2007 22:00:00 3.7 0.3 4.6 3 3.5 0.3 4.6 3 3.6 0.3 4.6 3 26 2 24 165 3 0 3.3 2.8 02/07/2007 22:10:00 3.4 0.3 4.2 2.6 3.2 0.3 4.2 2.3 3.4 0.3 4.2 2.6 25 3 25 165 3 0 3.3 2.8 02/07/2007 22:20:00 3.2 0.2 3.8 2.6 3 0.3 3.4 2.3 3.2 0.2 3.8 2.6 27 3 26 165 2.9 0.1 3.3 2.3 02/07/2007 22:30:00 3.1 0.2 3.4 2.6 3 0.2 3.4 2.3 3.1 0.2 3.8 2.3 22 2 25 165 2.9 0.1 3 2.3 02/07/2007 22:40:00 2.9 0.2 3.4 2.3 2.6 0.2 3 2.3 2.8 0.2 3.4 2.3 24 1 20 165 2.9 0.1 3 2.3 02/07/2007 22:50:00 2.7 0.3 3.4 2.3 2.5 0.2 3 2.3 2.7 0.2 3.4 2.3 30 1 27 165 2.9 0.1 3.3 2.3 02/07/2007 23:00:00 2.7 0.2 3.4 2.3 2.6 0.2 3 2.3 2.7 0.2 3.4 2.3 32 2 31 165 3 0.1 3.3 2.3 02/07/2007 23:10:00 2.3 0.2 2.6 1.5 2.1 0.2 2.6 1.5 2.4 0.2 3 1.9 35 3 32 165 3 0.1 3.3 2.3 02/07/2007 23:20:00 2.1 0.2 2.6 1.5 1.9 0.2 2.3 1.5 2.2 0.2 2.6 1.9 36 3 39 165 2.9 0 3.3 2.3 02/07/2007 23:30:00 2.2 0.2 2.6 1.9 2.1 0.2 2.6 1.5 2.3 0.2 2.6 1.9 29 1 30 165 2.9 0 3 2.3 02/07/2007 23:40:00 2 0.3 3 1.1 1.9 0.3 3 1.1 2 0.4 2.6 1.1 42 12 91 165 2.9 0 3 2.3 02/07/2007 23:50:00 1.7 0.3 2.3 1.1 1.6 0.2 2.3 1.1 1.7 0.3 2.3 1.1 44 3 46 165 2.9 0.1 3 2.3 02/08/2007 00:00:00 2 0.2 2.6 1.5 1.9 0.2 2.3 1.5 2.1 0.2 2.6 1.5 35 4 29 165 2.9 0 3.3 2.8 02/08/2007 00:10:00 2 0.3 3 1.1 1.9 0.3 2.6 1.1 2.2 0.3 2.6 1.5 32 4 35 165 2.9 0 3 2.3 02/08/2007 00:20:00 1.6 0.2 2.3 1.1 1.5 0.2 1.9 0.7 1.6 0.2 1.9 1.1 27 4 37 165 2.9 0 3.3 2.3 02/08/2007 00:30:00 1 0.4 1.5 0.4 1.2 0.3 1.9 0.7 1.1 0.2 1.5 0.4 30 5 23 165 3 0 3.3 2.3 02/08/2007 00:40:00 1 0.3 2.3 0.4 1.2 0.3 2.6 0.4 1 0.3 1.9 0.4 48 9 65 165 3 0 3.3 2.8 02/08/2007 00:50:00 0.5 0.3 1.9 0.4 0.6 0.4 2.3 0.4 0.6 0.2 1.1 0.4 52 7 75 165 3 0 3.3 2.8 02/08/2007 01:00:00 1.1 0.4 2.3 0.4 1.3 0.4 2.3 0.4 1 0.4 1.9 0.4 75 9 77 165 3 0 3.3 2.8 02/08/2007 01:10:00 1.2 0.4 2.3 0.4 1.4 0.4 2.3 0.4 1.1 0.4 1.9 0.4 81 8 84 165 3 0 3.5 2.8 02/08/2007 01:20:00 1.2 0.5 2.3 0.4 1.3 0.5 2.3 0.4 1.2 0.5 2.3 0.4 82 10 84 165 3 0 3.3 2.8 02/08/2007 01:30:00 1.2 0.5 2.6 0.4 1.2 0.4 2.6 0.4 1.4 0.4 2.3 0.7 96 7 89 165 3.1 0 3.5 3 02/08/2007 01:40:00 0.5 0.2 1.1 0.4 0.5 0.2 1.1 0.4 0.6 0.4 1.5 0.4 91 5 96 165 3 0 3.5 3 02/08/2007 01:50:00 0.4 0 0.7 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 100 2 94 165 3.2 0 3.3 3 02/08/2007 02:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.7 0.4 100 2 165 165 3 0 3.3 2.8 02/08/2007 02:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 94 3 165 165 3 0 3 2.8 02/08/2007 02:20:00 0.6 0.4 1.5 0.4 0.6 0.4 1.5 0.4 0.7 0.4 1.5 0.4 103 1 104 165 3.2 0 3.5 2.8 02/08/2007 02:30:00 1.1 0.2 1.5 0.7 1.2 0.2 1.5 0.7 1.2 0.2 1.5 0.7 102 2 104 165 3.3 0 3.5 3.3 02/08/2007 02:40:00 0.5 0.2 1.1 0.4 1 0.4 1.5 0.4 0.9 0.3 1.5 0.4 102 2 103 165 3.3 0 3.5 3.3 02/08/2007 02:50:00 1 0.5 1.9 0.4 1.3 0.3 1.9 0.7 1.1 0.2 1.9 0.7 99 3 96 165 3.3 0 3.5 3 02/08/2007 03:00:00 1.8 0.2 2.3 1.5 2 0.2 2.3 1.5 1.7 0.3 2.3 1.1 103 6 110 165 3.3 0 3.5 3 02/08/2007 03:10:00 1.9 0.3 2.3 0.7 2.2 0.2 2.6 1.5 1.9 0.3 2.3 1.1 112 2 114 165 3.3 0 3.5 3 02/08/2007 03:20:00 1.9 0.2 2.3 1.5 2.1 0.2 2.6 1.5 1.9 0.2 2.3 1.5 112 5 112 165 3.3 0 3.5 3 02/08/2007 03:30:00 1.7 0.2 2.3 1.1 2.1 0.2 2.6 1.5 2 0.2 2.3 1.5 102 4 106 165 3.2 0 3.8 2.8 02/08/2007 03:40:00 1.5 0.2 2.3 1.1 1.9 0.2 2.3 1.5 1.9 0.2 2.3 1.5 93 2 88 165 3.1 0.1 3.3 2.6 02/08/2007 03:50:00 1.8 0.3 2.6 1.1 2.2 0.3 2.6 1.5 2.2 0.3 3 1.9 97 4 102 165 3.1 0 3.8 2.6 02/08/2007 04:00:00 2 0.2 2.6 1.5 2.4 0.2 3 1.9 2.4 0.2 2.6 1.5 100 2 105 165 3 0.1 3.3 2.6 02/08/2007 04:10:00 2 0.2 2.6 1.5 2.3 0.3 3 1.9 2.2 0.2 2.6 1.9 101 4 101 165 3 0.1 3.3 2.6 02/08/2007 04:20:00 1.9 0.2 2.3 0.7 2.1 0.2 2.6 1.1 2 0.2 2.6 1.5 105 3 103 165 3 0.1 3.3 2.3 02/08/2007 04:30:00 1.7 0.2 2.3 1.5 1.9 0.2 2.3 1.5 1.9 0.2 2.3 1.5 109 2 106 165 3 0 3.3 2.8 02/08/2007 04:40:00 1.8 0.3 2.3 1.1 1.8 0.3 2.6 1.1 1.8 0.3 2.6 1.1 111 5 111 165 3 0 3.3 2.8 02/08/2007 04:50:00 1.8 0.4 2.6 0.7 2 0.3 2.6 1.1 2 0.3 2.6 1.1 111 8 121 165 3 0 3.5 2.8 02/08/2007 05:00:00 1.9 0.2 2.3 1.5 2.1 0.2 2.6 1.5 2.1 0.3 2.6 1.5 110 5 105 165 3 0 3.3 2.8 02/08/2007 05:10:00 1.7 0.2 2.3 1.1 1.8 0.2 2.3 1.5 1.9 0.3 2.6 1.5 110 1 111 165 2.9 0 3 2.6 02/08/2007 05:20:00 0.9 0.3 1.5 0.4 1.1 0.3 1.9 0.7 1 0.3 1.9 0.4 110 1 111 165 2.9 0 3.3 2.6 02/08/2007 05:30:00 1.8 0.2 2.3 1.1 2 0.3 2.6 1.1 2 0.3 2.6 1.1 114 2 116 165 2.9 0 3.3 2.6 02/08/2007 05:40:00 1.4 0.2 1.9 1.1 1.7 0.2 2.3 1.1 1.5 0.2 1.9 0.7 116 1 116 165 3 0 3.3 2.8 02/08/2007 05:50:00 0.7 0.3 1.5 0.4 0.8 0.4 1.5 0.4 0.7 0.3 1.5 0.4 115 1 113 165 3 0 3.3 2.8 02/08/2007 06:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 115 2 165 165 3 0 3 2.8 02/08/2007 06:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 115 2 165 165 3 0 3.3 2.3 02/08/2007 06:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 115 2 165 165 3 0 3.3 2.8 02/08/2007 06:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 115 2 165 165 3 0 3.3 2.8 02/08/2007 06:40:00 0.4 0.1 0.7 0.4 0.4 0.1 0.7 0.4 0.4 0.1 0.7 0.4 115 1 116 165 3 0 3.3 2.8 02/08/2007 06:50:00 0.9 0.2 1.5 0.4 0.8 0.2 1.1 0.4 0.8 0.2 1.1 0.4 116 1 116 165 3 0 3.3 2.8 02/08/2007 07:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0.1 1.1 0.4 115 2 165 165 2.9 0 3.3 2.6 02/08/2007 07:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 115 2 165 165 2.9 0 3 2.8 02/08/2007 07:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 115 2 165 165 2.9 0 3 2.6 02/08/2007 07:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 114 1 165 165 3 0 3.3 2.8 02/08/2007 07:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 114 1 165 165 3 0.1 3.5 2.3 02/08/2007 07:50:00 0.4 0.2 1.5 0.4 0.4 0 0.4 0.4 0.5 0.3 1.5 0.4 112 4 107 165 2.9 0.1 3.3 2.3 02/08/2007 08:00:00 1.1 0.2 1.5 0.7 0.4 0 0.4 0.4 1.1 0.3 1.5 0.4 106 2 111 165 2.9 0 3.3 2.3 02/08/2007 08:10:00 0.8 0.2 1.1 0.4 0.4 0 0.4 0.4 0.8 0.2 1.5 0.4 102 1 99 165 2.9 0.1 3 2.3 02/08/2007 08:20:00 1.1 0.2 1.5 0.7 0.4 0 0.4 0.4 1.2 0.2 1.5 0.7 102 1 103 165 2.9 0.1 3 2.3 02/08/2007 08:30:00 0.5 0.3 1.1 0.4 0.4 0 0.4 0.4 0.6 0.3 1.5 0.4 102 1 102 165 2.9 0.1 3.3 2.3 02/08/2007 08:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 101 1 165 165 2.9 0 3.3 2.3 02/08/2007 08:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.8 0.2 1.1 0.4 86 4 165 165 2.9 0 3 2.8 02/08/2007 09:00:00 0.4 0.2 1.1 0.4 0.4 0 0.4 0.4 0.6 0.3 1.1 0.4 89 1 87 165 2.9 0.1 3.3 2.3 02/08/2007 09:10:00 0.9 0.2 1.5 0.4 0.4 0 0.4 0.4 1.1 0.2 1.5 0.7 96 5 89 165 3 0.1 3.3 2.6 02/08/2007 09:20:00 0.9 0.2 1.1 0.4 0.4 0 0.4 0.4 1.2 0.2 1.5 0.7 106 2 99 165 3 0.1 3.3 2.6 02/08/2007 09:30:00 1.7 0.3 2.3 0.7 1.8 0.5 2.6 0.4 1.9 0.2 2.3 1.1 103 2 100 165 3 0 3.3 2.8 02/08/2007 09:40:00 1.9 0.2 2.3 1.5 2.2 0.2 2.6 1.9 2 0.3 2.6 1.1 100 3 102 165 3 0 3.3 2.8 02/08/2007 09:50:00 1.6 0.2 2.3 1.1 1.7 0.3 2.3 1.1 1.7 0.3 2.3 1.1 98 1 99 165 3 0 3 2.8 02/08/2007 10:00:00 1 0.4 1.9 0.4 0.8 0.5 1.9 0.4 0.9 0.5 1.9 0.4 98 1 102 165 3 0 3 2.8 02/08/2007 10:10:00 0.4 0.1 1.1 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 98 1 98 165 3 0 3.3 2.8 02/08/2007 10:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 98 2 165 165 3 0 3.3 2.8 02/08/2007 10:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 98 1 165 165 3 0 3.3 2.8 02/08/2007 10:40:00 0.6 0.4 1.5 0.4 0.6 0.3 1.5 0.4 0.6 0.4 1.9 0.4 97 2 98 165 3 0 3.3 2.8 02/08/2007 10:50:00 0.5 0.2 1.1 0.4 0.4 0.1 0.7 0.4 0.5 0.2 1.1 0.4 89 4 98 165 3 0 3.3 2.8 02/08/2007 11:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 88 1 165 165 3.2 0 3.3 3 02/08/2007 11:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 88 1 165 165 3.2 0 3.5 3 02/08/2007 11:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 79 5 165 165 3.4 0 3.5 3.3 02/08/2007 11:30:00 0.4 0.2 1.1 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 69 5 67 165 3.5 0 3.8 3.3 02/08/2007 11:40:00 0.5 0.2 1.1 0.4 0.4 0.1 1.1 0.4 0.4 0.1 1.1 0.4 85 8 66 165 3.6 0 3.8 3.5 02/08/2007 11:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 90 0 165 165 3.8 0 4 3.5 02/08/2007 12:00:00 0.4 0 0.7 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 80 7 105 165 3.8 0 4 3.8 02/08/2007 12:10:00 0.4 0.2 1.1 0.4 0.4 0.1 1.1 0.4 0.4 0.2 1.1 0.4 115 3 116 165 3.8 0 4 3.8 02/08/2007 12:20:00 0.6 0.3 1.1 0.4 0.5 0.3 1.1 0.4 0.6 0.3 1.5 0.4 118 3 116 165 3.6 0 4 3.5 02/08/2007 12:30:00 1.1 0.3 1.9 0.4 1.1 0.3 1.9 0.4 1.2 0.3 1.9 0.4 121 0 121 165 3.6 0 3.8 3.5 02/08/2007 12:40:00 0.9 0.3 1.9 0.4 1.1 0.3 1.9 0.4 1.1 0.3 1.9 0.4 120 5 128 165 3.6 0 3.8 3.5 02/08/2007 12:50:00 0.6 0.3 1.5 0.4 0.8 0.3 1.5 0.4 0.6 0.3 1.1 0.4 111 1 110 165 3.6 0 3.8 3.5 02/08/2007 13:00:00 0.4 0.1 1.1 0.4 0.4 0.2 1.1 0.4 0.4 0 0.4 0.4 112 0 112 165 3.6 0 3.8 3.5 02/08/2007 13:10:00 0.4 0.2 1.5 0.4 0.4 0.1 1.1 0.4 0.4 0.1 1.1 0.4 122 17 163 165 3.9 0.1 4.3 3.5 02/08/2007 13:20:00 0.5 0.3 1.5 0.4 0.4 0.2 1.5 0.4 0.5 0.3 1.5 0.4 148 8 164 165 4 0 4.5 3.8 02/08/2007 13:30:00 0.4 0 0.4 0.4 0.4 0 0.7 0.4 0.4 0 0.7 0.4 159 9 165 165 3.9 0 4.3 3.8 02/08/2007 13:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 164 0 165 165 3.6 0 3.8 3.5 02/08/2007 13:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 164 0 165 165 3.9 0 4.3 3.8 02/08/2007 14:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 147 21 165 165 4 0 4.3 3.8 02/08/2007 14:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 107 11 165 165 3.8 0 4.3 3.5 02/08/2007 14:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 94 0 165 165 3.7 0.1 4 3.5 02/08/2007 14:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 94 0 165 165 3.8 0 4.3 3.5 02/08/2007 14:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 94 0 165 165 3.8 0 4.3 3.5 02/08/2007 14:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 94 0 165 165 3.5 0 3.8 3.5 02/08/2007 15:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 95 1 165 165 3.5 0 3.5 3.5 02/08/2007 15:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 91 7 165 165 3.6 0 3.8 3.5 02/08/2007 15:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.7 0.4 108 6 165 165 3.2 0.2 3.5 3 02/08/2007 15:30:00 0.4 0 0.4 0.4 0.4 0 0.7 0.4 0.4 0 0.4 0.4 105 8 165 165 3 0 3.3 2.8 02/08/2007 15:40:00 1.2 0.4 1.9 0.4 1.2 0.4 2.3 0.4 0.8 0.5 1.9 0.4 77 5 73 165 3 0 3.3 2.8 02/08/2007 15:50:00 1.1 0.3 1.9 0.4 1.2 0.3 1.9 0.4 0.8 0.4 1.5 0.4 70 5 60 165 3.2 0 3.5 2.8 02/08/2007 16:00:00 1.2 0.2 1.9 0.7 1.2 0.3 1.9 0.4 0.9 0.3 1.5 0.4 51 8 60 165 3 0.1 3.5 2.6 02/08/2007 16:10:00 0.6 0.3 1.5 0.4 0.7 0.3 1.5 0.4 0.4 0.1 0.7 0.4 56 5 65 165 3 0 3.3 2.6 02/08/2007 16:20:00 0.9 0.5 2.3 0.4 1.2 0.5 2.3 0.4 0.7 0.4 1.9 0.4 78 6 81 165 3 0.1 3.3 2.6 02/08/2007 16:30:00 0.6 0.3 1.5 0.4 1 0.3 1.5 0.4 0.5 0.3 1.5 0.4 80 3 78 165 3 0.1 3.3 2.6 02/08/2007 16:40:00 0.9 0.4 1.9 0.4 1.2 0.3 2.3 0.7 0.8 0.3 1.5 0.4 72 4 70 165 2.9 0 3.3 2.3 02/08/2007 16:50:00 1.2 0.4 2.3 0.4 1.4 0.3 2.6 0.7 1 0.4 1.9 0.4 65 4 69 165 2.9 0 3.3 2.8 02/08/2007 17:00:00 1.9 0.4 2.6 1.1 2 0.3 2.6 1.1 1.4 0.5 2.3 0.4 63 4 75 165 2.8 0 3 2.6 02/08/2007 17:10:00 1.9 0.3 2.6 1.5 2 0.3 2.6 1.5 1.7 0.2 2.6 1.1 58 6 64 165 2.8 0 3 2.6 02/08/2007 17:20:00 1.4 0.4 2.3 0.4 1.5 0.4 2.3 0.4 1.2 0.4 2.3 0.4 47 11 52 165 2.9 0 3 2.6 02/08/2007 17:30:00 1.4 0.3 1.9 0.4 1.4 0.3 2.3 0.7 1.2 0.2 1.5 0.7 50 7 56 165 2.9 0 3.3 2.6 02/08/2007 17:40:00 1.3 0.2 1.9 0.7 1.3 0.2 1.9 0.7 1.1 0.3 1.5 0.4 48 4 48 165 2.8 0 3 2.6 02/08/2007 17:50:00 1.7 0.3 2.3 1.1 1.7 0.2 2.3 1.1 1.6 0.4 2.3 0.7 39 5 35 165 2.8 0 3 2.6 02/08/2007 18:00:00 2.3 0.2 3 1.9 2.2 0.2 2.6 1.9 2.2 0.2 2.6 1.5 38 2 37 165 2.7 0 3 2.6 02/08/2007 18:10:00 2.2 0.2 2.6 1.9 2 0.2 2.6 1.5 2 0.3 2.6 1.5 35 2 35 165 2.7 0 2.8 2.6 02/08/2007 18:20:00 2.3 0.3 3 1.5 2.2 0.4 3 1.5 2 0.3 3 1.5 43 4 46 165 2.7 0 2.8 2.6 02/08/2007 18:30:00 2.6 0.4 3.4 1.9 2.6 0.4 3.8 1.5 2.3 0.4 3.4 1.5 46 4 51 165 2.8 0 3 2.3 02/08/2007 18:40:00 3.5 0.4 4.2 2.3 3.7 0.4 4.6 2.3 3.3 0.4 4.6 1.9 55 5 55 165 2.9 0.1 3.3 2.3 02/08/2007 18:50:00 3.6 0.4 4.2 2.6 3.7 0.4 4.6 2.6 3.4 0.4 4.2 2.6 64 6 61 165 3 0 3 2.8 02/08/2007 19:00:00 4.1 0.3 4.9 3 4.3 0.4 4.9 3.4 4 0.3 4.6 3 73 5 71 165 3 0 3.3 2.8 02/08/2007 19:10:00 4.2 0.2 4.6 3.8 4.5 0.2 4.9 4.2 4.3 0.2 4.9 3.8 84 4 74 165 3 0 3.3 2.8 02/08/2007 19:20:00 4.3 0.2 4.6 3.8 4.6 0.2 4.9 4.2 4.4 0.2 4.9 3.8 93 3 91 165 3 0 3.3 2.8 02/08/2007 19:30:00 4.3 0.2 4.9 3.8 4.6 0.2 4.9 4.2 4.2 0.3 4.6 3.4 97 2 99 165 3 0 3.3 2.8 02/08/2007 19:40:00 4.4 0.2 4.9 4.2 4.7 0.2 5.3 4.2 4.5 0.2 4.9 3.8 102 4 100 165 3 0 3.3 2.8 02/08/2007 19:50:00 4.7 0.3 5.7 3.8 4.9 0.3 5.7 3.8 4.6 0.4 5.3 3.4 107 4 109 165 3 0 3.5 2.8 02/08/2007 20:00:00 4.7 0.5 5.7 3.8 4.8 0.5 5.7 3.8 4.5 0.5 5.3 3 106 8 108 165 3 0 3.3 2.8 02/08/2007 20:10:00 4.8 0.4 5.3 3.8 4.8 0.4 5.7 3.8 4.6 0.4 5.3 3.4 113 5 108 165 3 0 3.3 2.8 02/08/2007 20:20:00 5 0.4 5.7 3.8 5 0.4 6.1 3.8 4.7 0.4 5.7 3.4 114 4 111 165 3 0 3.3 2.8 02/08/2007 20:30:00 5.6 0.4 6.5 4.6 5.6 0.3 6.5 4.2 5.4 0.4 6.5 4.2 117 5 116 165 2.9 0 3.3 2.8 02/08/2007 20:40:00 6.4 0.7 8 4.9 6.4 0.7 8.4 4.6 6.2 0.7 8 4.6 119 7 118 165 2.8 0 3.5 2.6 02/08/2007 20:50:00 6.1 0.7 8 4.2 6.2 0.6 7.6 4.6 6.1 0.6 8 4.9 129 8 131 165 2.6 0 2.8 2.6 02/08/2007 21:00:00 5.7 0.6 7.2 4.2 5.8 0.6 7.6 4.6 5.8 0.7 7.6 4.2 131 7 128 165 2.6 0 2.8 2.6 02/08/2007 21:10:00 4.7 0.6 6.5 3.4 4.9 0.6 6.5 3.4 4.9 0.5 6.1 3.4 131 8 127 165 2.7 0 2.8 2.6 02/08/2007 21:20:00 4.6 0.4 5.7 3 4.8 0.4 5.7 3.4 4.9 0.5 6.5 3.8 134 8 143 165 2.6 0 2.8 2.6 02/08/2007 21:30:00 4.7 0.7 6.1 3 4.8 0.7 6.5 3 4.8 0.7 6.5 2.6 133 8 122 165 2.6 0 2.8 2.6 02/08/2007 21:40:00 4.5 0.6 6.1 3 4.7 0.6 6.1 3 4.6 0.6 6.5 3 136 7 144 165 2.5 0 2.8 2.3 02/08/2007 21:50:00 4.1 0.6 5.7 3 4.2 0.7 6.1 3 4.2 0.6 6.5 2.6 139 9 135 165 2.5 0 2.6 2.3 02/08/2007 22:00:00 4.3 0.4 5.3 3 4.3 0.5 5.3 2.6 4.4 0.4 5.3 3.4 140 8 134 165 2.4 0 2.6 2.3 02/08/2007 22:10:00 3.4 0.7 5.7 1.9 3.2 0.8 5.7 1.5 3.5 0.9 5.7 2.3 142 12 148 165 2.4 0.1 2.8 1.8 02/08/2007 22:20:00 3.8 0.6 5.3 2.6 3.7 0.6 4.9 2.6 3.8 0.5 5.3 2.3 141 9 148 165 2.4 0.1 2.8 1.8 02/08/2007 22:30:00 3.8 0.5 4.6 2.3 3.6 0.5 4.6 2.3 3.7 0.5 4.9 2.3 143 6 143 165 2.4 0.1 2.6 1.8 02/08/2007 22:40:00 3.3 0.3 4.2 2.3 3.1 0.4 3.8 2.3 3.1 0.4 4.2 1.9 143 9 128 165 2.4 0.1 2.6 1.8 02/08/2007 22:50:00 3.3 0.4 4.6 2.3 3.1 0.4 4.2 2.3 3.2 0.4 4.2 2.3 148 5 144 165 2.4 0.1 2.6 1.8 02/08/2007 23:00:00 3 0.6 4.6 1.9 2.8 0.6 4.2 1.5 3 0.5 4.2 1.9 150 9 133 165 2.5 0.1 2.8 1.8 02/08/2007 23:10:00 3 0.5 4.2 1.9 2.9 0.4 3.8 1.9 2.9 0.5 4.2 1.9 150 6 144 165 2.4 0.1 2.6 2.1 02/08/2007 23:20:00 2.4 0.5 3.4 1.1 2.2 0.5 3.4 1.1 2.3 0.4 3.4 1.5 145 8 121 165 2.5 0.1 2.8 2.1 02/08/2007 23:30:00 2.6 0.4 3.4 1.9 2.4 0.4 3 1.5 2.4 0.3 3 1.5 143 5 137 165 2.4 0.1 2.8 1.8 02/08/2007 23:40:00 2.3 0.3 3 1.5 2.1 0.3 3 1.1 2.2 0.3 3 1.5 141 8 145 165 2.4 0.1 2.6 1.8 02/08/2007 23:50:00 2.7 0.4 3.8 1.9 2.7 0.4 3.8 1.9 2.6 0.5 3.8 1.9 133 6 129 165 2.4 0 2.6 2.1 02/09/2007 00:00:00 2.8 0.4 3.8 1.5 2.8 0.4 3.4 1.5 2.8 0.4 3.8 1.9 132 5 134 165 2.4 0.1 2.8 1.8 02/09/2007 00:10:00 2.9 0.3 3.4 1.9 2.9 0.3 3.4 2.3 2.8 0.3 3.4 1.9 125 5 117 165 2.4 0.1 2.6 1.8 02/09/2007 00:20:00 2.7 0.3 3.4 1.9 2.7 0.4 3.8 1.9 2.5 0.5 3.4 1.1 117 6 128 165 2.4 0.1 2.6 1.8 02/09/2007 00:30:00 2.8 0.2 3.4 2.3 2.8 0.2 3.4 2.3 2.7 0.3 3.4 1.9 119 3 122 165 2.4 0 2.6 2.3 02/09/2007 00:40:00 2.4 0.2 3 1.9 2.4 0.2 3 1.9 2.4 0.2 3 1.5 117 1 118 165 2.4 0 2.6 2.3 02/09/2007 00:50:00 1.8 0.2 2.3 1.5 1.9 0.2 2.3 1.5 1.7 0.2 2.3 1.1 117 1 117 165 2.3 0 2.6 1.8 02/09/2007 01:00:00 1.6 0.3 1.9 0.4 1.6 0.3 1.9 0.4 1.3 0.4 1.9 0.4 114 3 116 165 2.1 0 2.3 1.6 02/09/2007 01:10:00 1.4 1.2 3.4 0.4 1.5 1.2 3.4 0.4 1.3 1.2 3.4 0.4 102 12 114 165 2.1 0 2.3 1.8 02/09/2007 01:20:00 2.9 0.3 3.4 2.3 3 0.3 3.4 2.3 2.9 0.3 3.4 2.3 111 3 115 165 2.1 0 2.3 1.8 02/09/2007 01:30:00 3.4 0.2 3.8 2.6 3.4 0.2 3.8 3 3.3 0.2 3.8 2.6 109 2 110 165 2.1 0 2.3 1.8 02/09/2007 01:40:00 3.6 0.2 4.2 3 3.6 0.2 4.2 3 3.5 0.2 4.2 3 110 3 106 165 2.2 0 2.6 1.8 02/09/2007 01:50:00 3.8 0.2 4.6 3 3.7 0.2 4.6 3 3.6 0.3 4.2 3 115 3 116 165 2.3 0 2.6 1.8 02/09/2007 02:00:00 4 0.2 4.6 3.4 3.9 0.2 4.2 3.4 3.7 0.3 4.2 2.3 115 2 116 165 2.3 0 2.6 2.1 02/09/2007 02:10:00 3.9 0.2 4.2 3.4 3.9 0.2 4.2 3.4 3.9 0.2 4.2 3.4 112 2 113 165 2.3 0 2.6 2.3 02/09/2007 02:20:00 3.2 0.4 4.2 2.3 3.2 0.4 3.8 2.6 3.3 0.4 3.8 2.3 106 5 109 165 2.3 0 2.6 1.8 02/09/2007 02:30:00 3.5 0.2 3.8 3 3.5 0.2 3.8 3 3.4 0.2 3.8 2.6 102 2 103 165 2.3 0 2.6 2.1 02/09/2007 02:40:00 3.7 0.2 4.2 3 3.8 0.3 4.2 3.4 3.4 0.3 4.2 2.3 103 2 106 165 2.3 0 2.6 1.8 02/09/2007 02:50:00 3.9 0.2 4.6 3 4 0.2 4.6 3 3.5 0.4 4.2 2.6 101 3 102 165 2.3 0 2.6 2.1 02/09/2007 03:00:00 3.7 0.2 4.2 3 3.7 0.2 4.2 3 3.4 0.3 4.2 2.3 100 3 104 165 2.3 0 2.6 2.1 02/09/2007 03:10:00 3.9 0.2 4.2 3 3.9 0.2 4.2 3.4 3.6 0.3 4.2 2.6 99 2 101 165 2.3 0 2.6 1.6 02/09/2007 03:20:00 4 0.2 4.2 3.4 4 0.2 4.2 3.4 3.7 0.2 4.2 3 100 2 99 165 2.3 0 2.6 1.6 02/09/2007 03:30:00 4.3 0.2 4.6 3.4 4.4 0.2 4.6 3.4 4.1 0.4 4.6 2.6 102 3 105 165 2.3 0.1 2.8 1.6 02/09/2007 03:40:00 4.2 0.2 4.6 3.4 4.3 0.2 4.9 3.8 4.1 0.2 4.6 3 96 2 99 165 2.4 0.1 2.6 1.8 02/09/2007 03:50:00 4.1 0.2 4.6 3.8 4.2 0.2 4.6 3.8 4.2 0.2 4.6 3.4 90 2 93 165 2.4 0 2.6 1.8 02/09/2007 04:00:00 4.1 0.2 4.6 3.8 4.2 0.2 4.6 3.8 4.2 0.2 4.6 3.4 87 3 87 165 2.4 0 2.6 2.1 02/09/2007 04:10:00 4.1 0.2 4.6 3.8 4.2 0.2 4.6 3.8 4.2 0.2 4.6 3.4 83 1 82 165 2.4 0 2.6 1.8 02/09/2007 04:20:00 4 0.2 4.6 3.4 4.1 0.2 4.6 3.8 4.2 0.2 4.6 3.4 85 2 84 165 2.4 0.1 2.6 1.8 02/09/2007 04:30:00 4.1 0.2 4.6 3.4 4.3 0.2 4.6 3.8 4.1 0.3 4.9 3.4 93 4 88 165 2.4 0 2.6 1.8 02/09/2007 04:40:00 4.1 0.2 4.6 3.4 4.2 0.2 4.9 3.8 3.8 0.3 4.6 3 94 2 96 165 2.3 0 2.6 1.8 02/09/2007 04:50:00 4.5 0.3 4.9 3.4 4.7 0.3 5.3 3.8 4.3 0.4 5.3 3 91 3 90 165 2.3 0 2.6 1.8 02/09/2007 05:00:00 4.8 0.2 5.3 4.2 5 0.2 5.3 4.6 4.7 0.2 5.3 4.2 85 2 83 165 2.4 0 2.6 2.3 02/09/2007 05:10:00 4.9 0.2 5.3 4.2 5.1 0.2 5.7 4.2 4.8 0.3 5.3 4.2 86 3 76 165 2.4 0 2.6 2.3 02/09/2007 05:20:00 5 0.2 5.3 4.6 5.2 0.2 5.7 4.6 4.9 0.3 5.3 3.8 88 2 91 165 2.4 0 2.6 2.1 02/09/2007 05:30:00 5.1 0.2 5.7 4.6 5.2 0.2 5.7 4.6 4.9 0.3 5.7 4.2 88 2 85 165 2.4 0 2.8 2.3 02/09/2007 05:40:00 5.5 0.2 5.7 4.9 5.7 0.2 6.1 5.3 5.5 0.2 6.1 4.9 90 2 89 165 2.4 0 2.6 2.3 02/09/2007 05:50:00 5.3 0.2 5.7 4.9 5.4 0.2 5.7 4.9 5.3 0.2 5.7 4.6 90 2 91 165 2.4 0 2.6 2.3 02/09/2007 06:00:00 5.2 0.3 5.7 3.8 5.4 0.3 6.1 4.2 4.9 0.4 5.7 3.4 94 4 89 165 2.4 0 2.8 2.3 02/09/2007 06:10:00 5.6 0.4 6.5 4.2 5.7 0.4 6.8 4.2 5.1 0.5 6.1 3.4 98 4 105 165 2.4 0 2.6 2.3 02/09/2007 06:20:00 6 0.3 6.8 4.9 6.1 0.3 6.8 4.9 5.7 0.4 6.5 4.6 104 4 98 165 2.4 0 2.6 2.3 02/09/2007 06:30:00 5.3 0.3 6.1 4.2 5.5 0.3 6.1 4.2 5.1 0.5 6.1 3.8 97 4 102 165 2.3 0 2.6 1.8 02/09/2007 06:40:00 4.9 0.4 5.7 3.8 5 0.4 5.7 3.8 4.5 0.4 5.3 3.4 95 2 102 165 2.2 0 2.3 1.8 02/09/2007 06:50:00 4.7 0.3 5.3 3.8 4.8 0.3 5.3 4.2 4.4 0.4 4.9 3 96 2 97 165 2.1 0 2.3 1.6 02/09/2007 07:00:00 4.5 0.3 5.3 3.8 4.6 0.3 5.3 3.8 4.2 0.4 4.9 3 98 3 99 165 2.1 0 2.3 1.8 02/09/2007 07:10:00 4.3 0.3 4.9 3.4 4.3 0.3 4.9 3.4 4.1 0.4 4.9 2.6 96 6 102 165 2.1 0 2.3 1.6 02/09/2007 07:20:00 3.9 0.3 4.6 3.4 4 0.2 4.6 3.4 3.9 0.3 4.6 3.4 82 2 85 165 2.1 0 2.6 1.8 02/09/2007 07:30:00 3.6 0.2 4.2 3 3.7 0.2 4.2 3 3.6 0.3 4.2 3 91 7 93 165 2 0 2.3 1.8 02/09/2007 07:40:00 3.9 0.3 4.6 3 4 0.3 4.6 3 3.9 0.4 4.6 2.6 92 4 87 165 2.1 0 2.3 1.8 02/09/2007 07:50:00 4.1 0.3 4.6 3.4 4.1 0.3 4.6 3.4 3.9 0.3 4.6 3 99 3 96 165 2.1 0 2.3 1.8 02/09/2007 08:00:00 3.5 0.3 4.2 2.6 3.6 0.3 4.2 3 3.6 0.3 4.2 3 80 8 74 165 2.1 0 2.3 1.8 02/09/2007 08:10:00 3.6 0.4 4.6 2.6 3.7 0.4 4.6 2.6 3.5 0.4 4.6 2.6 87 9 102 165 2.2 0 2.3 1.6 02/09/2007 08:20:00 3.8 0.5 4.6 2.6 3.9 0.5 4.9 2.6 3.9 0.6 4.9 2.6 86 5 84 165 2.1 0 2.3 1.8 02/09/2007 08:30:00 3.7 0.3 4.6 3 3.9 0.3 4.6 3 3.9 0.3 4.6 3.4 90 3 87 165 2.1 0 2.6 2.1 02/09/2007 08:40:00 3.4 0.3 4.2 2.6 3.5 0.3 4.2 2.6 3.5 0.3 4.2 2.6 96 6 99 165 2.1 0 2.3 1.6 02/09/2007 08:50:00 3.2 0.3 4.2 2.6 3.3 0.3 4.6 2.6 3.3 0.3 4.2 2.3 102 4 102 165 2.1 0 2.3 2.1 02/09/2007 09:00:00 3.1 0.2 3.8 2.3 3.2 0.3 3.8 2.6 3.1 0.2 3.8 2.3 107 6 113 165 2.2 0 2.6 1.8 02/09/2007 09:10:00 3.6 0.4 4.2 2.6 3.6 0.4 4.2 2.6 3.4 0.4 4.2 2.3 110 4 118 165 2.4 0 2.6 1.8 02/09/2007 09:20:00 4.2 0.3 4.9 3.4 4.2 0.3 4.9 3.4 4 0.4 4.6 2.6 116 4 119 165 2.4 0 2.6 2.3 02/09/2007 09:30:00 4.2 0.4 5.3 2.6 4.1 0.4 4.9 2.6 4 0.5 4.9 2.3 118 6 123 165 2.4 0 2.6 2.3 02/09/2007 09:40:00 4.3 0.5 5.3 2.6 4.2 0.5 5.3 2.6 4.1 0.5 4.9 2.6 122 6 118 165 2.4 0 2.6 2.3 02/09/2007 09:50:00 4.1 0.4 4.9 3 4 0.4 4.9 3 3.9 0.4 4.9 3 126 6 126 165 2.5 0 2.8 2.3 02/09/2007 10:00:00 4 0.4 4.9 3 3.9 0.4 4.6 3 3.8 0.3 4.6 2.6 130 7 128 165 2.5 0 2.8 2.3 02/09/2007 10:10:00 3.6 0.5 4.9 2.3 3.6 0.5 4.6 1.9 3.5 0.5 4.6 2.3 126 7 116 165 2.6 0 2.8 2.6 02/09/2007 10:20:00 3.4 0.5 4.2 2.3 3.3 0.4 4.2 2.3 3.3 0.4 4.2 2.3 132 9 128 165 2.6 0 2.8 2.6 02/09/2007 10:30:00 3.3 0.4 4.2 2.3 3.2 0.4 4.2 1.9 3 0.4 4.2 1.9 132 7 139 165 2.6 0 2.8 2.6 02/09/2007 10:40:00 2.9 0.5 4.2 1.5 2.8 0.5 4.2 1.9 2.7 0.6 3.8 1.1 133 8 130 165 2.7 0 2.8 2.6 02/09/2007 10:50:00 3.2 0.4 4.2 1.9 3.1 0.5 4.2 1.9 2.9 0.5 3.8 1.9 127 7 122 165 2.7 0 2.8 2.6 02/09/2007 11:00:00 3.8 0.7 4.9 1.9 3.8 0.7 4.9 1.9 3.6 0.6 4.9 1.9 121 6 121 165 2.7 0 2.8 2.6 02/09/2007 11:10:00 3.5 0.4 4.6 2.3 3.5 0.4 4.6 2.3 3.3 0.4 4.2 1.9 118 5 123 165 2.7 0 2.8 2.6 02/09/2007 11:20:00 3.2 0.5 4.2 1.9 3.2 0.5 4.2 1.9 2.9 0.5 3.8 1.5 111 7 119 165 2.7 0 2.8 2.6 02/09/2007 11:30:00 4.2 0.4 4.9 3 4.2 0.4 4.9 2.6 4 0.5 4.6 2.3 110 5 105 165 2.7 0 2.8 2.6 02/09/2007 11:40:00 4.2 0.4 4.9 3 4.2 0.4 4.9 3.4 4 0.4 4.6 2.6 117 3 114 165 2.6 0 2.8 2.6 02/09/2007 11:50:00 3.7 0.4 4.6 2.6 3.7 0.4 4.9 3 3.4 0.5 4.6 2.3 109 7 110 165 2.6 0 2.8 2.1 02/09/2007 12:00:00 3.2 0.4 4.2 1.9 3.2 0.4 3.8 1.9 3 0.4 4.2 1.9 105 8 110 165 2.7 0 2.8 2.3 02/09/2007 12:10:00 3.2 0.4 4.2 2.3 3.3 0.4 4.2 2.3 2.9 0.4 3.8 1.9 102 8 95 165 2.7 0 2.8 2.6 02/09/2007 12:20:00 2.5 0.6 3.8 1.1 2.6 0.5 3.8 1.1 2.3 0.6 3.4 0.7 104 11 109 165 2.8 0 3 2.6 02/09/2007 12:30:00 2.5 0.5 3.8 1.1 2.5 0.5 3.8 0.7 2.4 0.5 3.4 1.1 109 7 105 165 2.9 0 3 2.8 02/09/2007 12:40:00 2.2 0.4 3.4 1.5 2.2 0.4 3 1.5 1.9 0.4 3 0.4 129 9 139 165 2.9 0 3.3 2.8 02/09/2007 12:50:00 2.4 0.5 3.4 0.7 2.3 0.5 3.4 0.7 2.1 0.5 3 0.7 114 9 123 165 2.9 0 3.3 2.8 02/09/2007 13:00:00 2.7 0.4 3.4 1.5 2.6 0.4 3.4 1.5 2.3 0.5 3.4 0.7 109 5 104 165 2.9 0 3 2.6 02/09/2007 13:10:00 2.3 0.4 3.4 1.5 2.3 0.4 3.4 1.5 2 0.5 3.4 0.7 111 9 117 165 2.9 0 3 2.8 02/09/2007 13:20:00 2.2 0.3 3 1.5 2.2 0.3 3 1.5 2 0.4 2.6 1.1 115 6 117 165 2.9 0 3 2.8 02/09/2007 13:30:00 1.8 0.5 3 0.7 1.8 0.5 2.6 0.4 1.4 0.6 2.6 0.4 100 6 92 165 2.9 0 3 2.6 02/09/2007 13:40:00 1.6 0.8 3 0.4 1.6 0.9 3 0.4 1.3 0.9 3 0.4 91 6 86 165 2.9 0 3.3 2.3 02/09/2007 13:50:00 1.2 0.6 2.6 0.4 1.2 0.6 2.6 0.4 1 0.6 2.6 0.4 98 17 90 165 2.9 0 3 2.3 02/09/2007 14:00:00 2 0.4 2.6 0.7 2 0.5 2.6 0.7 1.7 0.5 2.6 0.4 80 6 73 165 2.9 0 3.3 2.6 02/09/2007 14:10:00 2.4 0.3 3 1.5 2.5 0.3 3 1.5 2.3 0.3 3 1.5 80 4 79 165 2.8 0 3 2.3 02/09/2007 14:20:00 2 0.2 2.6 1.1 2 0.2 2.6 1.5 1.8 0.3 2.3 1.1 85 4 93 165 2.9 0 3 2.3 02/09/2007 14:30:00 1.8 0.2 2.3 1.1 1.8 0.2 2.3 1.1 1.7 0.2 2.3 1.1 78 3 82 165 2.9 0 3 2.8 02/09/2007 14:40:00 1.9 0.2 2.6 1.5 2 0.3 2.6 1.5 1.9 0.3 2.6 1.5 78 3 76 165 2.9 0 3.5 2.8 02/09/2007 14:50:00 1.9 0.2 2.6 1.5 1.9 0.2 2.6 1.5 1.8 0.2 2.3 1.1 74 1 75 165 2.8 0 3 2.6 02/09/2007 15:00:00 1.7 0.3 2.3 1.1 1.7 0.3 2.6 0.7 1.6 0.3 2.3 0.7 69 6 74 165 2.9 0 3 2.8 02/09/2007 15:10:00 1.8 0.2 2.3 1.1 1.6 0.2 2.3 1.1 1.6 0.4 2.3 0.4 58 3 58 165 2.9 0 3 2.8 02/09/2007 15:20:00 1.8 0.2 2.6 1.1 1.7 0.3 2.3 0.7 1.7 0.3 2.3 1.1 58 2 57 165 2.9 0 3 2.8 02/09/2007 15:30:00 1.7 0.2 2.3 1.5 1.6 0.2 1.9 1.1 1.7 0.2 2.3 1.1 61 2 63 165 2.8 0 3 2.6 02/09/2007 15:40:00 2.1 0.3 2.6 1.5 1.9 0.3 2.3 1.1 1.9 0.3 2.6 0.7 55 5 58 165 2.9 0 3.3 2.8 02/09/2007 15:50:00 1.9 0.3 2.6 0.7 1.7 0.3 2.3 0.7 1.7 0.4 2.6 0.7 34 5 29 165 2.7 0 3 2.3 02/09/2007 16:00:00 1.7 0.2 2.3 1.1 1.4 0.3 1.9 0.7 1.3 0.3 1.9 0.7 38 5 39 165 2.7 0 3 2.1 02/09/2007 16:10:00 2 0.3 2.6 1.1 1.8 0.4 2.6 1.1 1.6 0.4 2.6 0.7 58 7 68 165 2.6 0 2.8 1.8 02/09/2007 16:20:00 2 0.3 2.6 1.1 1.9 0.3 2.3 1.1 1.6 0.3 2.3 0.7 60 5 63 165 2.6 0 2.8 2.3 02/09/2007 16:30:00 1.9 0.4 2.6 1.1 1.7 0.4 2.6 0.7 1.5 0.4 2.6 0.7 57 6 65 165 2.6 0 2.8 1.8 02/09/2007 16:40:00 1.5 0.3 2.3 0.7 1.2 0.4 2.3 0.7 0.8 0.4 1.9 0.4 53 6 52 165 2.5 0.1 2.8 1.8 02/09/2007 16:50:00 1.7 0.3 2.6 1.1 1.4 0.3 2.3 0.7 1.3 0.4 2.3 0.4 52 3 56 165 2.5 0 2.8 1.8 02/09/2007 17:00:00 1.3 0.3 2.3 0.7 1.1 0.3 2.3 0.7 1 0.2 2.3 0.4 43 5 47 165 2.5 0 2.8 2.3 02/09/2007 17:10:00 1.6 0.4 2.6 0.4 1.3 0.4 2.6 0.4 1.2 0.3 2.3 0.4 49 9 68 165 2.5 0 2.8 2.3 02/09/2007 17:20:00 2.9 0.4 3.8 1.9 2.9 0.4 3.8 1.9 2.7 0.5 3.8 1.1 79 8 77 165 2.5 0 2.8 2.1 02/09/2007 17:30:00 3.3 0.3 4.2 2.6 3.4 0.3 4.2 2.6 3.2 0.4 3.8 2.3 79 8 68 165 2.5 0 2.8 2.1 02/09/2007 17:40:00 3.4 0.3 4.2 2.3 3.5 0.3 4.2 2.3 3.3 0.3 4.2 2.3 68 4 70 165 2.4 0 2.6 1.8 02/09/2007 17:50:00 3.2 0.3 3.8 2.3 3.3 0.4 3.8 2.3 3.1 0.4 3.8 2.3 71 4 72 165 2.4 0 2.6 1.8 02/09/2007 18:00:00 2.6 0.4 3.8 1.9 2.6 0.5 3.8 1.5 2.4 0.5 3.4 1.1 62 6 68 165 2.4 0 2.6 1.8 02/09/2007 18:10:00 2.2 0.5 3.4 1.1 2.2 0.5 3.4 1.1 1.9 0.4 3 0.7 63 6 65 165 2.4 0 2.6 1.8 02/09/2007 18:20:00 2.3 0.5 3.4 1.1 2.3 0.5 3.4 1.1 2.1 0.5 3 0.7 61 6 62 165 2.4 0 2.6 2.3 02/09/2007 18:30:00 1.9 0.3 2.3 1.1 1.8 0.3 2.6 1.1 1.7 0.3 2.6 0.7 50 5 44 165 2.4 0 2.8 2.3 02/09/2007 18:40:00 2.3 0.4 3 1.5 2.3 0.4 3 1.5 2.2 0.4 3 1.1 59 9 57 165 2.4 0 2.6 1.8 02/09/2007 18:50:00 2.7 0.5 3.8 1.5 2.7 0.5 3.8 1.9 2.5 0.5 3.8 1.5 75 4 78 165 2.4 0.1 2.6 1.8 02/09/2007 19:00:00 2.6 0.3 3.4 1.9 2.6 0.3 3.4 1.9 2.4 0.3 3.4 1.5 73 5 79 165 2.4 0 2.6 1.8 02/09/2007 19:10:00 2.7 0.3 3.8 1.9 2.7 0.3 3.8 1.5 2.4 0.4 3 1.5 68 5 70 165 2.4 0 2.8 1.8 02/09/2007 19:20:00 2.3 0.3 3 1.9 2.4 0.3 3 1.5 2.2 0.3 3 1.5 76 6 73 165 2.4 0 2.6 2.1 02/09/2007 19:30:00 2.9 0.3 3.8 2.3 3 0.3 3.8 2.3 2.8 0.3 3.4 1.9 83 5 79 165 2.4 0 2.6 2.3 02/09/2007 19:40:00 2.9 0.2 3.4 2.3 3 0.2 3.4 2.6 2.9 0.2 3.4 2.6 83 3 85 165 2.4 0 2.6 2.3 02/09/2007 19:50:00 2.5 0.3 3 1.9 2.6 0.3 3 1.9 2.6 0.3 3 1.9 78 3 81 165 2.4 0 2.8 2.3 02/09/2007 20:00:00 2.3 0.3 3 1.5 2.4 0.3 3 1.5 2.2 0.3 3 1.5 72 3 68 165 2.4 0 2.8 2.3 02/09/2007 20:10:00 2.1 0.3 2.6 1.5 2.1 0.3 2.6 1.5 1.9 0.3 2.6 1.1 72 4 74 165 2.4 0 2.6 2.3 02/09/2007 20:20:00 1.9 0.3 2.6 1.5 1.9 0.3 2.6 1.1 1.8 0.3 2.6 1.1 66 3 72 165 2.4 0 2.8 2.3 02/09/2007 20:30:00 1.7 0.2 2.3 1.1 1.7 0.2 2.3 1.1 1.5 0.2 1.9 1.1 63 3 64 165 2.4 0 2.6 2.3 02/09/2007 20:40:00 1.9 0.3 2.3 1.1 1.8 0.3 2.6 1.1 1.7 0.3 2.3 1.1 60 3 63 165 2.4 0 2.6 2.3 02/09/2007 20:50:00 2 0.2 2.6 1.5 2 0.2 2.3 1.5 2 0.2 2.6 1.5 58 2 59 165 2.4 0 2.6 1.8 02/09/2007 21:00:00 2.3 0.3 2.6 1.5 2.3 0.3 3 1.5 2.2 0.3 2.6 1.5 66 4 61 165 2.4 0.1 2.6 1.8 02/09/2007 21:10:00 2.4 0.2 3 1.9 2.6 0.2 3 2.3 2.5 0.2 3 1.9 70 3 73 165 2.4 0.1 2.6 2.1 02/09/2007 21:20:00 2.2 0.1 2.6 1.9 2.4 0.2 2.6 1.9 2.4 0.2 2.6 1.9 72 2 73 165 2.4 0.1 2.6 2.1 02/09/2007 21:30:00 2.2 0.2 2.6 1.9 2.3 0.2 2.6 1.9 2.4 0.2 2.6 1.9 76 4 70 165 2.4 0.1 2.6 2.1 02/09/2007 21:40:00 2 0.2 2.3 1.5 2.2 0.2 2.6 1.9 2.1 0.2 2.6 1.5 87 2 84 165 2.4 0 2.6 2.3 02/09/2007 21:50:00 1.7 0.2 1.9 1.5 1.8 0.2 2.3 1.5 1.8 0.2 2.3 1.1 85 4 88 165 2.4 0.1 2.6 2.1 02/09/2007 22:00:00 1.7 0.2 1.9 1.5 1.7 0.2 2.3 1.5 1.7 0.2 2.3 1.5 80 2 81 165 2.4 0 2.6 2.3 02/09/2007 22:10:00 1.4 0.2 1.9 1.1 1.5 0.2 2.3 1.1 1.4 0.2 1.9 1.1 80 2 81 165 2.5 0 2.8 2.3 02/09/2007 22:20:00 1.2 0.2 1.5 0.7 1.3 0.2 1.9 0.7 1.2 0.2 1.5 0.7 78 5 81 165 2.5 0 2.8 2.3 02/09/2007 22:30:00 1 0.2 1.5 0.7 1.1 0.3 1.9 0.7 1 0.3 1.5 0.4 66 4 73 165 2.4 0 2.6 2.3 02/09/2007 22:40:00 0.5 0.2 1.5 0.4 0.5 0.2 1.1 0.4 0.4 0.1 1.1 0.4 46 5 47 165 2.4 0 2.6 2.1 02/09/2007 22:50:00 0.6 0.3 1.1 0.4 0.7 0.3 1.1 0.4 0.7 0.3 1.5 0.4 38 2 39 165 2.4 0 2.8 2.3 02/09/2007 23:00:00 1.2 0.2 1.5 0.7 1.1 0.2 1.5 0.7 1.3 0.2 1.9 0.7 30 2 39 165 2.5 0 2.8 2.3 02/09/2007 23:10:00 1.3 0.2 1.9 0.7 1.3 0.2 1.9 0.7 1.4 0.3 1.9 0.7 27 4 18 165 2.5 0 2.8 2.3 02/09/2007 23:20:00 1.5 0.2 1.9 1.1 1.4 0.2 1.9 0.7 1.4 0.2 1.9 0.7 37 3 39 165 2.5 0 2.8 2.3 02/09/2007 23:30:00 1.7 0.2 2.3 1.1 1.5 0.2 1.9 1.1 1.8 0.2 2.3 1.1 31 3 31 165 2.5 0 2.8 2.3 02/09/2007 23:40:00 1.9 0.2 2.6 1.5 1.8 0.2 2.3 1.5 2 0.2 2.3 1.5 22 3 20 165 2.5 0 2.8 2.3 02/09/2007 23:50:00 1.9 0.2 2.3 1.5 1.8 0.2 2.3 1.1 1.9 0.2 2.3 1.1 19 3 21 165 2.5 0 2.8 2.3 02/10/2007 00:00:00 2 0.2 2.3 1.5 1.9 0.2 2.3 1.5 2 0.2 2.6 1.5 26 5 22 165 2.5 0 2.8 2.3 02/10/2007 00:10:00 1.7 0.2 2.3 1.1 1.6 0.2 2.3 1.1 1.8 0.2 2.3 1.1 30 3 32 165 2.5 0 2.8 2.3 02/10/2007 00:20:00 1.9 0.3 2.6 1.1 1.8 0.3 2.6 1.1 2 0.3 2.6 1.5 30 3 32 165 2.5 0 2.8 2.3 02/10/2007 00:30:00 1.7 0.3 2.3 1.1 1.8 0.2 2.3 1.1 1.7 0.3 2.3 1.1 36 5 32 165 2.5 0 2.8 2.3 02/10/2007 00:40:00 2.3 0.2 2.6 1.9 2.3 0.2 2.6 1.9 2.2 0.3 2.6 1.5 35 3 29 165 2.5 0 2.8 2.3 02/10/2007 00:50:00 2.4 0.2 2.6 1.9 2.4 0.2 2.6 1.9 2.4 0.2 3 1.9 36 4 36 165 2.5 0 2.8 2.3 02/10/2007 01:00:00 2.4 0.2 2.6 1.9 2.4 0.2 3 1.9 2.5 0.2 3 1.9 37 4 41 165 2.4 0 2.6 2.3 02/10/2007 01:10:00 2.4 0.2 2.6 1.9 2.2 0.2 2.6 1.9 2.5 0.2 3 2.3 27 3 33 165 2.4 0 2.6 2.3 02/10/2007 01:20:00 1.9 0.4 2.6 1.1 1.8 0.4 2.6 0.7 1.9 0.4 3 1.1 33 4 25 165 2.4 0 2.6 2.3 02/10/2007 01:30:00 1.6 0.2 2.3 1.1 1.5 0.2 2.3 1.1 1.6 0.2 2.3 1.1 41 4 41 165 2.4 0 2.6 2.3 02/10/2007 01:40:00 1.4 0.3 2.3 0.7 1.4 0.2 1.9 0.7 1.5 0.2 2.3 0.7 40 3 34 165 2.4 0 2.6 2.3 02/10/2007 01:50:00 1.3 0.3 1.9 0.7 1.3 0.2 1.9 0.7 1.4 0.3 2.3 0.4 41 3 46 165 2.4 0 2.8 2.3 02/10/2007 02:00:00 2 0.2 2.6 1.5 1.9 0.2 2.6 1.5 2.1 0.2 2.6 1.5 47 4 50 165 2.4 0 2.6 2.1 02/10/2007 02:10:00 2 0.2 2.3 1.5 2 0.2 2.6 1.5 2.2 0.2 2.6 1.9 50 3 54 165 2.3 0 2.6 1.8 02/10/2007 02:20:00 1.5 0.3 2.3 0.7 1.5 0.3 2.3 0.7 1.6 0.3 2.3 0.7 47 5 44 165 2.4 0 2.8 2.1 02/10/2007 02:30:00 1.4 0.3 2.3 0.7 1.4 0.2 2.3 0.7 1.4 0.3 1.9 0.7 42 5 44 165 2.4 0 2.6 2.1 02/10/2007 02:40:00 1.3 0.3 1.9 0.7 1.3 0.2 1.9 0.7 1.4 0.3 1.9 0.7 30 5 36 165 2.4 0 2.8 2.3 02/10/2007 02:50:00 1.3 0.3 1.9 0.4 1.3 0.3 1.9 0.7 1.5 0.4 2.3 0.4 31 2 30 165 2.4 0 2.6 2.1 02/10/2007 03:00:00 0.9 0.2 1.5 0.4 0.9 0.2 1.5 0.4 0.6 0.3 1.5 0.4 31 2 31 165 2.4 0 2.6 2.3 02/10/2007 03:10:00 1.5 0.4 2.3 0.7 1.4 0.3 1.9 0.7 1.3 0.4 2.3 0.4 37 3 40 165 2.3 0 2.6 1.8 02/10/2007 03:20:00 1.5 0.3 1.9 0.7 1.4 0.2 1.9 0.7 1.4 0.3 1.9 0.7 35 4 39 165 2.4 0 2.6 2.1 02/10/2007 03:30:00 1 0.2 1.5 0.4 1 0.2 1.5 0.7 0.9 0.4 1.5 0.4 41 6 45 165 2.3 0 2.6 2.1 02/10/2007 03:40:00 0.7 0.3 1.1 0.4 0.9 0.2 1.5 0.4 0.7 0.3 1.5 0.4 45 2 46 165 2.3 0 2.8 1.8 02/10/2007 03:50:00 1.2 0.3 1.9 0.4 1.4 0.3 1.9 0.7 1.4 0.3 1.9 0.4 49 3 46 165 2.3 0 2.8 2.1 02/10/2007 04:00:00 1.5 0.2 1.9 1.1 1.5 0.2 1.9 1.1 1.7 0.2 1.9 1.1 52 1 52 165 2.1 0 2.3 1.8 02/10/2007 04:10:00 1.6 0.3 2.3 1.1 1.5 0.3 2.3 1.1 1.6 0.2 2.3 1.1 50 2 52 165 2.1 0 2.3 1.8 02/10/2007 04:20:00 1.7 0.2 2.3 1.1 1.6 0.2 2.3 1.1 1.9 0.2 2.3 1.1 45 5 48 165 2.1 0 2.3 1.8 02/10/2007 04:30:00 1.8 0.2 2.3 1.5 1.6 0.2 2.3 1.1 1.7 0.2 2.3 1.1 33 4 35 165 2.1 0 2.6 1.8 02/10/2007 04:40:00 1.8 0.2 2.3 1.5 1.6 0.2 2.3 1.1 1.8 0.2 2.3 1.1 23 1 23 165 2.1 0 2.3 1.8 02/10/2007 04:50:00 2.1 0.2 2.6 1.5 2 0.2 2.6 1.5 2.3 0.2 3 1.9 22 2 23 165 2 0 2.3 1.8 02/10/2007 05:00:00 2 0.2 2.3 1.5 1.8 0.2 2.3 1.5 2.2 0.2 2.6 1.9 21 1 22 165 2.1 0 2.3 1.8 02/10/2007 05:10:00 1.2 0.4 2.3 0.7 1.1 0.4 1.9 0.4 1.2 0.4 2.3 0.4 29 5 22 165 2 0 2.3 1.8 02/10/2007 05:20:00 1.2 0.2 1.5 0.7 1.1 0.2 1.5 0.7 1.2 0.2 1.9 0.7 31 1 32 165 2 0 2.3 1.8 02/10/2007 05:30:00 1 0.2 1.5 0.4 0.9 0.2 1.5 0.4 1.1 0.3 1.5 0.4 24 2 32 165 2 0 2.3 1.8 02/10/2007 05:40:00 0.6 0.3 1.1 0.4 0.5 0.2 1.1 0.4 0.6 0.3 1.1 0.4 15 1 16 165 2 0 2.6 1.8 02/10/2007 05:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 14 2 165 165 2 0 2.3 1.8 02/10/2007 06:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 14 2 165 165 1.9 0 2.1 1.6 02/10/2007 06:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 14 2 165 165 1.9 0 2.1 1.8 02/10/2007 06:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 14 2 165 165 1.9 0 2.1 1.8 02/10/2007 06:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 14 2 165 165 1.9 0 2.3 1.6 02/10/2007 06:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 14 2 165 165 1.8 0 2.3 1.6 02/10/2007 06:50:00 0.4 0 0.4 0.4 0.4 0.1 0.7 0.4 0.4 0 0.7 0.4 14 2 165 165 1.9 0 1.8 1.8 02/10/2007 07:00:00 0.4 0 0.4 0.4 0.4 0.1 0.7 0.4 0.4 0 0.4 0.4 14 2 165 165 1.9 0 2.1 1.8 02/10/2007 07:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 14 1 165 165 1.9 0 2.6 1.4 02/10/2007 07:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 14 2 165 165 1.9 0 2.1 1.8 02/10/2007 07:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 14 2 165 165 1.9 0 2.3 1.8 02/10/2007 07:40:00 0.9 0.5 1.5 0.4 0.8 0.4 1.5 0.4 0.8 0.5 1.9 0.4 16 3 15 165 1.9 0 2.6 1.8 02/10/2007 07:50:00 1.5 0.2 1.9 0.7 1.4 0.2 1.9 0.7 1.6 0.3 2.3 1.1 22 2 21 165 1.9 0 1.8 1.6 02/10/2007 08:00:00 0.8 0.2 1.1 0.4 0.8 0.2 1.1 0.4 1.1 0.2 1.5 0.7 31 6 26 165 1.9 0.1 2.1 1.4 02/10/2007 08:10:00 0.5 0.2 1.1 0.4 0.4 0.2 1.1 0.4 0.6 0.3 1.1 0.4 56 2 59 165 1.9 0.1 2.1 1.4 02/10/2007 08:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 54 2 165 165 1.9 0 2.3 1.6 02/10/2007 08:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 54 2 165 165 1.9 0 2.3 1.6 02/10/2007 08:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 54 2 165 165 1.8 0 2.3 1.4 02/10/2007 08:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 54 2 165 165 1.7 0 1.8 1.4 02/10/2007 09:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 54 2 165 165 1.9 0 2.1 1.6 02/10/2007 09:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 54 2 165 165 1.9 0 1.8 1.6 02/10/2007 09:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0.1 1.1 0.4 191 41 165 165 2 0 2.3 1.8 02/10/2007 09:30:00 1 0.3 1.5 0.4 0.6 0.4 1.5 0.4 0.8 0.5 1.5 0.4 187 4 189 165 2 0 2.3 1.8 02/10/2007 09:40:00 0.9 0.3 1.5 0.4 0.7 0.3 1.5 0.4 1 0.2 1.5 0.7 194 7 185 165 2.1 0 2.3 1.8 02/10/2007 09:50:00 0.7 0.3 1.5 0.4 0.5 0.3 1.5 0.4 0.8 0.4 1.9 0.4 213 6 214 165 2 0 2.3 1.8 02/10/2007 10:00:00 0.5 0.2 1.1 0.4 0.5 0.2 1.1 0.4 0.8 0.3 1.5 0.4 199 8 216 165 2.1 0 2.3 1.8 02/10/2007 10:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 200 2 165 165 2.1 0 2.3 1.8 02/10/2007 10:20:00 0.8 0.5 1.9 0.4 0.7 0.4 1.9 0.4 0.8 0.5 1.9 0.4 188 6 192 165 2.1 0 2.3 1.8 02/10/2007 10:30:00 1.4 0.4 2.3 0.7 1.2 0.4 1.9 0.4 1.6 0.3 2.6 0.7 182 5 177 165 2.1 0 2.3 2.1 02/10/2007 10:40:00 0.9 0.5 2.3 0.4 0.8 0.5 1.9 0.4 1 0.5 2.3 0.4 175 1 179 165 2.1 0 2.3 2.1 02/10/2007 10:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0.1 1.1 0.4 188 7 165 165 2.3 0 2.6 2.1 02/10/2007 11:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 190 1 165 165 2.3 0 2.6 2.3 02/10/2007 11:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 190 0 165 165 2.4 0 2.8 2.3 02/10/2007 11:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 190 1 165 165 2.4 0 2.6 2.3 02/10/2007 11:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 190 1 165 165 2.4 0 2.6 2.3 02/10/2007 11:40:00 0.6 0.4 1.5 0.4 0.5 0.3 1.1 0.4 0.9 0.5 1.9 0.4 175 7 172 165 2.3 0 2.6 2.1 02/10/2007 11:50:00 0.4 0.1 1.1 0.4 0.4 0.1 1.1 0.4 0.4 0.2 1.1 0.4 175 6 187 165 2.3 0 2.6 2.3 02/10/2007 12:00:00 0.4 0.1 1.1 0.4 0.4 0.2 1.1 0.4 0.6 0.3 1.5 0.4 203 9 187 165 2.4 0 2.6 2.3 02/10/2007 12:10:00 1.3 0.4 2.3 0.7 1.2 0.3 1.9 0.4 1.5 0.3 2.3 1.1 189 9 180 165 2.3 0 2.6 2.1 02/10/2007 12:20:00 1.2 0.5 2.6 0.4 0.9 0.5 2.6 0.4 1.2 0.5 2.6 0.4 174 7 176 165 2.3 0 2.6 2.1 02/10/2007 12:30:00 0.7 0.3 1.5 0.4 0.5 0.3 1.5 0.4 0.6 0.4 2.3 0.4 168 6 170 165 2.2 0 2.6 2.1 02/10/2007 12:40:00 0.4 0.1 1.1 0.4 0.4 0 0.7 0.4 0.4 0 0.7 0.4 203 15 208 165 2.4 0 2.8 2.3 02/10/2007 12:50:00 0.4 0 0.7 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 191 21 165 165 2.4 0 2.8 2.3 02/10/2007 13:00:00 0.4 0.2 1.1 0.4 0.4 0.1 0.7 0.4 0.4 0.1 1.1 0.4 159 5 155 165 2.3 0 2.6 2.1 02/10/2007 13:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 164 1 165 165 2.3 0 2.6 2.1 02/10/2007 13:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0.1 0.7 0.4 164 1 165 165 2.3 0 2.6 2.1 02/10/2007 13:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0.1 1.1 0.4 162 6 165 165 2.2 0 2.3 2.1 02/10/2007 13:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 144 1 165 165 2.3 0 2.6 2.1 02/10/2007 13:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 144 1 165 165 2.4 0 2.6 2.3 02/10/2007 14:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 148 1 165 165 2.1 0 2.3 2.1 02/10/2007 14:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 148 1 165 165 2.2 0 2.3 2.1 02/10/2007 14:20:00 0.5 0.3 1.5 0.4 0.5 0.2 1.5 0.4 0.5 0.3 1.5 0.4 163 8 165 165 2.1 0 2.3 1.8 02/10/2007 14:30:00 0.5 0.2 1.1 0.4 0.4 0 0.4 0.4 0.6 0.3 1.1 0.4 165 0 165 165 2 0 2.3 1.8 02/10/2007 14:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0.1 1.1 0.4 165 0 165 165 2.1 0 2.6 1.8 02/10/2007 14:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 165 0 165 165 2.1 0 2.3 1.8 02/10/2007 15:00:00 0.4 0.1 1.1 0.4 0.4 0.1 0.7 0.4 0.4 0.2 1.1 0.4 165 0 165 165 2.2 0 2.3 1.8 02/10/2007 15:10:00 0.6 0.3 1.1 0.4 0.4 0.1 1.1 0.4 0.8 0.4 1.5 0.4 168 2 165 165 2 0.1 2.3 1.4 02/10/2007 15:20:00 0.5 0.3 1.5 0.4 0.5 0.2 1.5 0.4 0.6 0.3 1.5 0.4 169 2 170 165 1.9 0 2.1 1.6 02/10/2007 15:30:00 1.1 0.4 1.9 0.4 0.9 0.4 1.9 0.4 1.2 0.5 2.3 0.4 172 5 179 165 1.9 0 2.3 1.4 02/10/2007 15:40:00 1.2 0.5 1.9 0.4 1.1 0.4 1.9 0.4 1.5 0.5 2.3 0.4 170 5 173 165 1.9 0 2.1 1.8 02/10/2007 15:50:00 0.5 0.3 1.5 0.4 0.5 0.3 1.5 0.4 0.8 0.4 1.9 0.4 191 9 176 165 2 0 2.3 1.8 02/10/2007 16:00:00 0.4 0.1 1.1 0.4 0.4 0.1 1.1 0.4 0.4 0 0.4 0.4 190 5 196 165 2 0 2.3 1.8 02/10/2007 16:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 184 2 165 165 1.9 0 2.3 1.8 02/10/2007 16:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 182 1 165 165 1.9 0 2.1 1.6 02/10/2007 16:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 182 1 165 165 1.9 0 1.8 1.6 02/10/2007 16:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 1.1 0.4 180 4 165 165 1.9 0 2.1 1.6 02/10/2007 16:50:00 0.5 0.3 1.5 0.4 0.4 0.2 1.1 0.4 0.7 0.4 1.5 0.4 169 2 165 165 1.8 0 2.1 1.6 02/10/2007 17:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 169 1 165 165 1.8 0 1.8 1.4 02/10/2007 17:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 236 61 165 165 1.8 0 1.8 1.6 02/10/2007 17:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 317 1 165 165 1.8 0 1.8 1.6 02/10/2007 17:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 318 1 165 165 1.7 0 1.8 1.6 02/10/2007 17:40:00 0.4 0.2 1.1 0.4 0.4 0.1 0.7 0.4 0.5 0.3 1.5 0.4 178 26 160 165 1.5 0 1.8 1.1 02/10/2007 17:50:00 0.4 0.2 1.1 0.4 0.4 0.1 1.1 0.4 0.5 0.2 1.1 0.4 148 9 155 165 1.5 0 1.8 0.9 02/10/2007 18:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 136 5 165 165 1.5 0 1.6 0.9 02/10/2007 18:10:00 0.4 0 0.7 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 134 1 135 165 1.5 0 1.6 0.9 02/10/2007 18:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 135 1 165 165 1.5 0 1.6 1.1 02/10/2007 18:30:00 0.4 0.2 1.5 0.4 0.4 0.1 1.1 0.4 0.4 0 0.7 0.4 149 11 148 165 1.5 0 1.6 1.1 02/10/2007 18:40:00 1 0.4 1.9 0.4 0.8 0.4 1.5 0.4 0.9 0.5 1.9 0.4 169 6 174 165 1.6 0 1.8 1.6 02/10/2007 18:50:00 1.1 0.3 1.9 0.4 0.9 0.3 1.5 0.4 1.1 0.4 1.9 0.4 164 1 162 165 1.6 0 1.8 1.4 02/10/2007 19:00:00 1.6 0.5 2.6 0.7 1.5 0.5 2.3 0.7 1.7 0.5 2.6 0.7 164 3 163 165 1.6 0 1.8 1.4 02/10/2007 19:10:00 2.2 0.2 3 1.5 2 0.2 2.6 1.5 2.3 0.3 3 1.9 166 7 168 165 1.5 0 1.6 1.4 02/10/2007 19:20:00 2.5 0.2 3 1.9 2.3 0.2 3 1.9 2.5 0.3 3 1.9 163 12 162 165 1.5 0 1.6 1.4 02/10/2007 19:30:00 2.2 0.2 2.6 1.9 2 0.2 2.6 1.5 2.3 0.2 3 1.9 163 6 165 165 1.5 0 1.6 1.4 02/10/2007 19:40:00 2 0.2 2.3 1.5 1.8 0.2 2.3 1.1 2 0.2 2.3 1.5 167 4 161 165 1.5 0 1.6 1.4 02/10/2007 19:50:00 1.8 0.3 2.6 1.1 1.4 0.3 2.3 0.4 1.6 0.3 2.6 0.7 162 6 171 165 1.5 0 1.6 1.4 02/10/2007 20:00:00 0.6 0.4 1.9 0.4 0.4 0.2 1.1 0.4 0.5 0.3 1.5 0.4 157 6 165 165 1.5 0 1.8 1.4 02/10/2007 20:10:00 0.6 0.3 1.5 0.4 0.4 0.1 1.1 0.4 0.4 0 0.7 0.4 148 14 128 165 1.4 0 1.8 1.4 02/10/2007 20:20:00 1 0.5 1.9 0.4 0.8 0.4 1.5 0.4 0.9 0.4 1.5 0.4 118 5 122 165 1.4 0 1.8 1.4 02/10/2007 20:30:00 0.4 0.1 0.7 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 115 6 118 165 1.4 0 1.6 1.4 02/10/2007 20:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 97 3 165 165 1.4 0 1.6 1.4 02/10/2007 20:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 87 18 165 165 1.4 0 1.6 1.4 02/10/2007 21:00:00 0.4 0.1 1.1 0.4 0.4 0.1 0.7 0.4 0.4 0 0.7 0.4 41 5 36 165 1.4 0 1.6 1.4 02/10/2007 21:10:00 0.4 0.1 1.1 0.4 0.4 0.1 1.1 0.4 0.4 0 0.4 0.4 48 8 56 165 1.3 0 1.6 1.1 02/10/2007 21:20:00 0.5 0.2 1.1 0.4 0.5 0.2 1.1 0.4 0.4 0.1 0.7 0.4 63 8 76 165 1.4 0 1.6 1.1 02/10/2007 21:30:00 0.9 0.3 1.5 0.4 0.8 0.3 1.5 0.4 0.5 0.2 1.5 0.4 69 10 79 165 1.4 0 1.6 1.4 02/10/2007 21:40:00 0.4 0.2 1.1 0.4 0.4 0.1 1.1 0.4 0.4 0.1 1.1 0.4 48 13 58 165 1.4 0 1.6 1.4 02/10/2007 21:50:00 0.4 0 0.7 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 32 2 34 165 1.4 0 1.8 1.4 02/10/2007 22:00:00 0.8 0.4 1.9 0.4 0.6 0.3 1.9 0.4 0.5 0.2 1.5 0.4 48 8 56 165 1.3 0.1 1.4 0.9 02/10/2007 22:10:00 0.8 0.4 1.5 0.4 0.7 0.4 1.5 0.4 0.6 0.3 1.5 0.4 53 5 58 165 1.4 0 1.6 1.1 02/10/2007 22:20:00 0.7 0.4 1.5 0.4 0.5 0.3 1.5 0.4 0.4 0.2 1.1 0.4 48 5 49 165 1.4 0 1.6 1.1 02/10/2007 22:30:00 0.6 0.3 1.5 0.4 0.4 0.2 1.5 0.4 0.4 0.1 1.1 0.4 55 3 45 165 1.4 0 1.8 1.4 02/10/2007 22:40:00 0.5 0.2 1.1 0.4 0.4 0.1 0.7 0.4 0.4 0 0.7 0.4 39 3 41 165 1.4 0 1.6 0.9 02/10/2007 22:50:00 0.8 0.6 2.3 0.4 0.5 0.3 1.5 0.4 0.7 0.6 1.9 0.4 25 12 7 165 1.4 0 1.6 1.4 02/10/2007 23:00:00 2.4 0.4 3.4 1.5 1.3 0.6 2.6 0.4 2.4 0.4 3.4 1.1 2 5 357 165 1.4 0 1.6 1.4 02/10/2007 23:10:00 0.5 0.4 1.9 0.4 0.5 0.3 1.5 0.4 0.6 0.4 1.9 0.4 30 21 12 165 1.4 0 1.6 1.1 02/10/2007 23:20:00 0.8 0.4 1.9 0.4 0.5 0.3 1.5 0.4 0.6 0.3 1.5 0.4 77 28 102 165 1.4 0 1.6 0.9 02/10/2007 23:30:00 1.1 0.4 1.9 0.4 0.9 0.4 1.9 0.4 0.8 0.4 1.5 0.4 108 4 111 165 1.4 0 1.6 1.4 02/10/2007 23:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 110 2 165 165 1.4 0 1.8 1.4 02/10/2007 23:50:00 0.4 0 0.7 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 106 2 104 165 1.4 0 1.8 1.4 02/11/2007 00:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 106 2 165 165 1.4 0 1.6 1.4 02/11/2007 00:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 106 2 165 165 1.4 0 1.6 1.1 02/11/2007 00:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 106 1 165 165 1.4 0.1 1.6 0.9 02/11/2007 00:30:00 0.4 0 0.7 0.4 0.4 0 0.4 0.4 0.4 0 0.7 0.4 87 29 43 165 1.4 0 1.6 1.4 02/11/2007 00:40:00 0.5 0.3 1.5 0.4 0.4 0.1 1.1 0.4 0.5 0.4 1.9 0.4 20 13 355 165 1.4 0 1.6 1.4 02/11/2007 00:50:00 0.8 0.4 1.5 0.4 0.7 0.3 1.5 0.4 1 0.3 1.9 0.4 19 11 360 165 1.4 0 1.6 1.4 02/11/2007 01:00:00 1.1 0.6 2.3 0.4 1 0.6 2.3 0.4 1.4 0.5 2.3 0.4 17 7 23 165 1.4 0 1.6 1.4 02/11/2007 01:10:00 1.1 0.6 2.3 0.4 1 0.6 2.3 0.4 0.8 0.5 1.9 0.4 90 21 97 165 1.3 0 1.6 1.4 02/11/2007 01:20:00 1.5 0.5 2.6 0.4 1.5 0.5 2.6 0.4 1.1 0.5 2.3 0.4 99 1 99 165 1.4 0.1 1.6 0.9 02/11/2007 01:30:00 1.6 0.4 2.3 0.4 1.4 0.4 2.3 0.4 1.3 0.4 2.3 0.4 101 1 99 165 1.4 0.1 1.8 0.9 02/11/2007 01:40:00 1.4 0.5 2.3 0.4 1.2 0.5 2.3 0.4 0.9 0.5 2.6 0.4 104 1 104 165 1.4 0.1 1.8 0.9 02/11/2007 01:50:00 0.8 0.4 1.5 0.4 0.5 0.2 1.1 0.4 0.4 0.1 0.7 0.4 105 1 106 165 1.4 0.1 1.6 0.9 02/11/2007 02:00:00 1 0.7 2.6 0.4 0.8 0.6 2.6 0.4 0.8 0.7 2.3 0.4 105 1 104 165 1.4 0.1 1.6 0.9 02/11/2007 02:10:00 0.4 0.2 1.1 0.4 0.4 0 0.7 0.4 0.4 0.1 0.7 0.4 105 1 106 165 1.5 0 1.6 0.9 02/11/2007 02:20:00 0.4 0.1 1.1 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 105 1 106 165 1.5 0 1.6 0.9 02/11/2007 02:30:00 0.4 0.1 1.1 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 105 2 106 165 1.4 0.1 1.6 0.9 02/11/2007 02:40:00 0.7 0.3 1.5 0.4 0.4 0 0.4 0.4 0.4 0.2 1.5 0.4 105 1 106 165 1.4 0 1.6 1.4 02/11/2007 02:50:00 1.4 0.6 2.6 0.4 0.4 0 0.4 0.4 1.2 0.6 2.3 0.4 105 1 106 165 1.5 0 1.6 1.4 02/11/2007 03:00:00 1.7 0.5 3 0.4 0.4 0 0.4 0.4 1.3 0.7 3 0.4 105 1 106 165 1.5 0 1.6 1.4 02/11/2007 03:10:00 2.8 0.4 3.8 1.5 1.8 0.6 3.4 0.4 2.6 0.4 3.4 1.5 105 1 106 165 1.5 0 1.8 1.4 02/11/2007 03:20:00 2.6 0.5 3.8 1.5 1.5 0.9 3 0.4 1.7 0.9 3 0.4 105 1 106 165 1.4 0 1.8 1.4 02/11/2007 03:30:00 1.8 0.4 2.6 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 105 1 106 165 1.4 0 1.6 1.4 02/11/2007 03:40:00 0.9 0.6 2.3 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 105 2 105 165 1.4 0 1.6 1.4 02/11/2007 03:50:00 0.5 0.2 1.5 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 105 2 106 165 1.5 0 1.6 1.4 02/11/2007 04:00:00 2.5 0.7 3.8 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 105 1 106 165 1.5 0 1.6 1.4 02/11/2007 04:10:00 3.4 0.4 4.2 2.3 0.4 0 0.4 0.4 0.4 0 0.4 0.4 105 1 106 165 1.4 0 2.1 1.4 02/11/2007 04:20:00 2.1 0.5 3.4 0.7 0.4 0 0.4 0.4 0.4 0 0.4 0.4 105 1 102 165 1.4 0 1.6 1.1 02/11/2007 04:30:00 0.7 0.4 1.5 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 105 1 106 165 1.4 0 1.6 1.4 02/11/2007 04:40:00 1.4 0.7 3 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 106 1 106 165 1.5 0.1 3.5 1.4 02/11/2007 04:50:00 2.3 0.3 3 1.5 0.4 0 0.4 0.4 0.4 0 0.4 0.4 106 1 102 165 1.5 0 2.1 0.9 02/11/2007 05:00:00 2.8 0.3 3.8 1.9 0.4 0 0.4 0.4 0.4 0 0.4 0.4 105 1 102 165 1.4 0 1.6 0.9 02/11/2007 05:10:00 2.2 0.3 3 1.5 0.4 0 0.4 0.4 0.4 0 0.4 0.4 105 1 102 165 1.4 0.1 1.6 0.9 02/11/2007 05:20:00 2 0.3 2.6 1.1 0.4 0 0.4 0.4 0.4 0 0.4 0.4 105 1 106 165 1.4 0 1.6 1.4 02/11/2007 05:30:00 2.5 0.5 3.8 1.5 0.4 0 0.4 0.4 0.4 0 0.4 0.4 105 1 106 165 1.4 0 1.8 1.4 02/11/2007 05:40:00 2.5 0.3 3.4 1.9 0.4 0 0.4 0.4 0.4 0 0.7 0.4 106 1 106 165 1.5 0 1.6 0.9 02/11/2007 05:50:00 2.1 0.3 3 1.1 0.4 0 0.4 0.4 0.4 0 0.4 0.4 106 1 103 165 1.4 0 1.6 0.9 02/11/2007 06:00:00 2.4 0.4 3.4 1.1 0.4 0 0.4 0.4 0.4 0 0.4 0.4 106 1 102 165 1.4 0 1.6 1.4 02/11/2007 06:10:00 3.2 0.5 4.2 1.9 0.4 0 0.4 0.4 0.4 0 0.4 0.4 105 1 106 165 1.4 0 1.6 1.4 02/11/2007 06:20:00 4 0.6 4.9 2.6 0.4 0 0.4 0.4 0.4 0 0.4 0.4 105 1 106 165 1.4 0 1.6 1.4 02/11/2007 06:30:00 3.9 0.4 4.6 3 0.4 0 0.4 0.4 0.4 0 0.4 0.4 106 1 106 165 1.4 0 1.8 1.4 02/11/2007 06:40:00 3.8 0.3 4.6 3 0.4 0 0.4 0.4 0.4 0 0.4 0.4 106 1 106 165 1.4 0 1.6 1.4 02/11/2007 06:50:00 4.2 0.5 5.3 3 0.4 0 0.4 0.4 0.4 0 0.4 0.4 105 1 106 165 1.4 0 1.6 1.4 02/11/2007 07:00:00 4.6 0.4 5.3 3.8 0.4 0 0.4 0.4 0.4 0 0.4 0.4 105 1 103 165 1.4 0 1.6 0.9 02/11/2007 07:10:00 4.5 0.5 5.3 3 0.4 0 0.4 0.4 0.4 0 0.4 0.4 106 1 106 165 1.5 0 1.6 1.4 02/11/2007 07:20:00 3.7 0.8 5.3 1.9 0.4 0 0.4 0.4 0.4 0 0.4 0.4 106 1 106 165 1.5 0 1.6 1.4 02/11/2007 07:30:00 3.8 0.5 5.3 2.6 0.4 0 0.4 0.4 0.4 0 0.4 0.4 106 1 104 165 1.5 0 1.8 1.4 02/11/2007 07:40:00 3.9 0.5 4.9 1.9 0.4 0 0.4 0.4 0.4 0 0.4 0.4 106 1 106 165 1.5 0 1.8 1.4 02/11/2007 07:50:00 3.1 0.6 4.2 1.9 0.4 0 0.4 0.4 0.4 0 0.4 0.4 106 1 104 165 1.5 0 1.8 1.4 02/11/2007 08:00:00 3.3 0.6 4.6 1.5 0.4 0 0.4 0.4 0.4 0 0.4 0.4 106 1 106 165 1.5 0 1.6 1.4 02/11/2007 08:10:00 2.7 0.5 3.8 1.9 0.4 0 0.4 0.4 0.4 0 0.4 0.4 106 1 106 165 1.5 0 1.6 1.4 02/11/2007 08:20:00 2.8 0.5 4.2 1.9 0.4 0 0.4 0.4 0.4 0 0.4 0.4 106 1 106 165 1.5 0 1.6 1.4 02/11/2007 08:30:00 2.4 0.6 4.2 1.1 0.4 0 0.4 0.4 0.4 0 0.4 0.4 106 1 107 165 1.5 0 1.8 1.4 02/11/2007 08:40:00 3.4 0.9 4.9 1.5 0.4 0 0.4 0.4 0.4 0 0.7 0.4 106 1 107 165 1.5 0 1.8 1.4 02/11/2007 08:50:00 3.5 0.7 4.9 1.9 0.4 0 0.4 0.4 2.5 0.5 3.4 0.4 107 1 106 165 1.5 0 1.8 1.4 02/11/2007 09:00:00 3.2 0.5 4.9 1.9 0.4 0 0.4 0.4 2.5 0.6 4.6 1.1 107 1 106 165 1.5 0 1.6 1.4 02/11/2007 09:10:00 4.1 0.5 5.3 3 0.4 0 0.7 0.4 3.6 0.5 4.6 2.3 107 1 108 165 1.5 0 1.8 1.4 02/11/2007 09:20:00 4.5 0.5 6.1 3.4 0.9 1.1 4.2 0.4 4.2 0.6 5.7 3 107 1 109 165 1.5 0 1.6 1.4 02/11/2007 09:30:00 4.4 0.7 5.7 3 4 0.5 4.9 2.6 4.1 0.5 5.3 3 109 2 107 165 1.6 0 1.6 1.4 02/11/2007 09:40:00 3.6 0.4 4.6 2.6 3.6 0.4 4.6 2.6 3.6 0.4 4.9 2.6 111 2 111 165 1.6 0 1.8 1.4 02/11/2007 09:50:00 4.1 0.5 4.9 3 4 0.5 4.9 3 3.9 0.5 4.9 2.6 114 3 114 165 1.6 0 1.8 1.6 02/11/2007 10:00:00 4 0.5 5.3 2.6 4.1 0.5 4.9 3 3.9 0.5 4.9 2.6 127 7 138 165 1.7 0 1.8 1.6 02/11/2007 10:10:00 4 0.5 5.3 3 4.1 0.4 4.9 3 4.1 0.4 5.3 3 142 5 137 165 1.8 0 2.3 1.6 02/11/2007 10:20:00 3.7 0.6 4.9 2.3 3.8 0.6 5.3 2.3 3.7 0.6 5.3 2.3 144 4 142 165 1.9 0 2.1 1.8 02/11/2007 10:30:00 3 0.4 3.8 1.9 3.2 0.3 4.2 2.3 3.1 0.3 3.8 1.9 147 5 132 165 1.9 0 2.1 1.8 02/11/2007 10:40:00 3.9 0.6 5.3 2.6 3.9 0.6 4.9 3 3.7 0.5 5.3 2.6 144 4 148 165 2 0 2.6 1.8 02/11/2007 10:50:00 3.9 0.5 4.9 2.6 3.9 0.5 4.9 3 3.7 0.4 4.9 2.6 141 7 132 165 2.1 0 2.3 1.8 02/11/2007 11:00:00 4.9 0.6 6.5 3 5 0.6 6.5 3 4.8 0.6 6.1 3 142 6 139 165 2.3 0 2.6 2.1 02/11/2007 11:10:00 5.4 0.4 6.5 4.6 5.3 0.4 6.5 3.8 5.4 0.4 6.5 4.2 147 6 140 165 2.3 0 2.6 2.1 02/11/2007 11:20:00 4.5 0.5 5.7 3.4 4.5 0.4 5.7 3.4 4.5 0.4 5.7 3.4 153 4 154 165 2.3 0 2.6 2.1 02/11/2007 11:30:00 4.2 0.4 4.9 3 4.2 0.4 4.9 3 4.3 0.4 4.9 3 153 4 158 165 2.3 0 2.6 2.3 02/11/2007 11:40:00 4.6 0.4 5.3 3.8 4.6 0.4 5.3 3.4 4.7 0.4 5.7 3.8 148 7 156 165 2.3 0 2.8 2.3 02/11/2007 11:50:00 5.4 0.5 6.8 3.8 5.4 0.5 6.5 3.8 5.5 0.5 6.8 3.8 143 5 148 165 2.3 0 2.6 2.1 02/11/2007 12:00:00 6.7 0.6 8 5.3 6.7 0.6 8 5.3 6.7 0.6 8 5.3 140 4 141 165 2.2 0 2.6 2.1 02/11/2007 12:10:00 6.9 0.5 8 5.7 6.8 0.5 8 5.3 6.9 0.4 8 6.1 142 4 141 165 2.2 0 2.6 2.1 02/11/2007 12:20:00 7.2 0.4 9.1 6.1 7 0.4 9.1 6.1 7.1 0.4 8.4 6.1 147 5 145 165 2.2 0 2.6 2.1 02/11/2007 12:30:00 6.8 0.5 8.8 5.7 6.6 0.5 8.4 5.7 6.7 0.5 8 5.3 150 5 151 165 2.2 0 2.6 1.8 02/11/2007 12:40:00 6.4 0.4 7.6 4.9 6.2 0.4 7.2 4.9 6.4 0.4 7.2 5.3 149 5 153 165 2.2 0 2.3 2.1 02/11/2007 12:50:00 6.7 0.4 7.6 5.7 6.5 0.4 7.6 5.3 6.6 0.5 7.6 4.9 148 8 147 165 2.3 0 2.6 2.1 02/11/2007 13:00:00 7.3 0.5 8.4 5.7 7.1 0.5 8.4 5.3 7.2 0.5 8 6.1 148 9 147 165 2.3 0 2.6 2.3 02/11/2007 13:10:00 7.5 0.4 8.4 6.5 7.4 0.4 8 6.5 7.5 0.4 8.4 6.5 146 3 148 165 2.4 0 2.6 2.3 02/11/2007 13:20:00 7.7 0.4 8.8 6.8 7.6 0.4 8.4 6.5 7.7 0.4 8.8 6.5 148 3 150 165 2.4 0 2.6 2.3 02/11/2007 13:30:00 7 0.5 8 5.7 7 0.5 8 5.7 7.1 0.5 8.4 5.7 146 4 153 165 2.4 0 2.6 2.3 02/11/2007 13:40:00 6.4 0.4 7.2 5.3 6.3 0.4 6.8 4.9 6.3 0.4 7.2 5.3 151 4 147 165 2.4 0 2.6 2.3 02/11/2007 13:50:00 6.3 0.4 7.2 5.3 6.1 0.4 7.2 4.9 6.1 0.5 7.2 4.9 149 3 148 165 2.3 0 2.6 2.1 02/11/2007 14:00:00 6.1 0.4 6.8 4.9 5.9 0.4 6.8 4.6 5.9 0.5 6.8 4.9 148 4 146 165 2.3 0 2.6 2.1 02/11/2007 14:10:00 6.4 0.3 6.8 5.3 6.2 0.3 6.8 5.3 6.1 0.4 6.8 4.9 148 3 150 165 2.3 0 2.6 2.1 02/11/2007 14:20:00 5.8 0.5 6.8 4.6 5.6 0.4 6.5 4.6 5.6 0.5 6.8 4.6 141 4 143 165 2.4 0 2.6 2.3 02/11/2007 14:30:00 6.6 0.4 7.2 5.3 6.5 0.4 7.2 4.9 6.3 0.4 7.2 4.9 142 4 143 165 2.3 0 2.6 2.1 02/11/2007 14:40:00 7.1 0.5 8.4 5.7 7.2 0.5 8 5.3 7.1 0.5 8 5.3 142 4 140 165 2.3 0 2.6 2.1 02/11/2007 14:50:00 7.5 0.5 8.4 6.5 7.5 0.5 8.4 6.1 7.3 0.5 8.8 5.7 142 3 142 165 2.3 0 2.6 1.8 02/11/2007 15:00:00 7.1 0.5 8 6.1 7.2 0.4 8 6.5 7.1 0.4 8 5.7 142 4 147 165 2.3 0 2.6 1.8 02/11/2007 15:10:00 7.3 0.5 8.8 6.1 7.2 0.5 8.4 6.1 7.3 0.5 8.8 5.3 146 3 150 165 2.3 0 2.6 2.1 02/11/2007 15:20:00 8 0.5 9.5 6.8 7.8 0.5 9.1 6.8 7.9 0.5 9.1 6.1 150 3 151 165 2.3 0 2.8 1.8 02/11/2007 15:30:00 8 0.6 9.1 6.1 7.8 0.6 8.8 5.7 7.9 0.6 9.1 6.1 148 3 148 165 2.3 0 2.6 1.8 02/11/2007 15:40:00 8.4 0.5 9.5 6.8 8.2 0.5 9.5 6.8 8.2 0.5 9.9 6.5 147 4 151 165 2.3 0 2.6 1.6 02/11/2007 15:50:00 8.5 0.5 9.5 6.8 8.3 0.5 9.1 6.8 8.3 0.6 9.5 6.8 148 2 146 165 2.3 0 2.6 1.8 02/11/2007 16:00:00 8 0.4 8.8 7.2 7.9 0.4 8.8 6.8 7.9 0.4 8.8 6.5 146 3 148 165 2.3 0 2.6 1.8 02/11/2007 16:10:00 8.6 0.5 9.5 7.2 8.5 0.4 9.1 7.2 8.6 0.5 9.5 7.2 147 2 147 165 2.3 0 2.6 2.1 02/11/2007 16:20:00 8.2 0.5 9.9 7.2 8.2 0.5 9.9 6.8 8.1 0.5 9.9 6.5 144 3 137 165 2.3 0 2.6 2.3 02/11/2007 16:30:00 8.6 0.8 10.7 6.8 8.6 0.7 10.7 7.2 8.5 0.7 10.7 6.5 141 6 142 165 2.3 0 2.8 2.3 02/11/2007 16:40:00 8.9 0.7 11.1 6.8 8.7 0.7 10.7 6.8 8.7 0.6 10.3 7.2 140 6 140 165 2.4 0 2.6 2.3 02/11/2007 16:50:00 9.9 0.8 11.8 7.6 9.8 0.8 12.2 8.4 9.7 0.9 12.2 6.5 136 6 136 165 2.4 0 2.8 2.3 02/11/2007 17:00:00 10.3 0.8 11.8 7.6 10.2 0.8 11.8 7.6 10.1 0.8 12.2 7.6 139 5 140 165 2.4 0 2.6 2.3 02/11/2007 17:10:00 10.2 0.8 11.8 8 10.1 0.8 11.8 8 9.9 0.8 12.2 7.6 138 8 140 165 2.4 0 2.8 2.3 02/11/2007 17:20:00 10.9 0.9 13.3 8.4 10.8 0.9 12.6 8.4 10.7 0.9 13 8 139 6 142 165 2.4 0 2.6 2.3 02/11/2007 17:30:00 10.3 0.7 11.8 8 10.2 0.8 11.8 8 10.2 0.8 11.8 8 140 6 143 165 2.4 0 2.6 2.3 02/11/2007 17:40:00 10.3 0.5 11.5 8.8 10.2 0.5 11.8 8.8 10 0.6 11.5 8.4 142 4 141 165 2.4 0 2.6 2.3 02/11/2007 17:50:00 9.5 0.7 11.1 7.6 9.4 0.6 10.7 7.6 9.3 0.7 10.7 7.6 142 4 144 165 2.4 0 2.6 2.3 02/11/2007 18:00:00 9.7 0.8 11.8 6.5 9.6 0.9 11.8 6.5 9.4 0.9 11.8 6.8 138 6 144 165 2.4 0 2.6 2.3 02/11/2007 18:10:00 11.3 0.7 13.3 9.1 11.2 0.7 13.3 9.5 11.1 0.7 13 8.8 138 7 121 165 2.4 0 2.6 2.3 02/11/2007 18:20:00 10.7 0.7 13 9.1 10.7 0.7 12.6 9.1 10.5 0.6 12.2 8 136 6 143 165 2.4 0 2.6 2.3 02/11/2007 18:30:00 11.3 0.9 13.7 9.1 11.3 0.9 14.5 9.1 11.2 1 14.1 8.4 137 6 129 165 2.4 0 3 2.3 02/11/2007 18:40:00 11.1 1.1 13 7.2 11.1 1 13 7.6 11 1 13.3 8 135 6 132 165 2.4 0 2.6 2.3 02/11/2007 18:50:00 11.8 0.9 14.1 9.5 11.7 0.9 14.1 9.5 11.5 1.1 14.5 7.6 134 6 143 165 2.4 0 2.8 2.3 02/11/2007 19:00:00 11.7 0.8 13.7 9.9 11.6 0.8 14.1 9.9 11.6 0.9 13.7 9.1 139 6 136 165 2.4 0 2.8 2.1 02/11/2007 19:10:00 11.2 0.9 13 8.8 11.1 0.8 13 8.8 11 0.8 13 8.4 139 5 146 165 2.3 0 2.6 2.1 02/11/2007 19:20:00 11.1 0.8 13.3 9.1 11 0.8 13 8.8 11 0.8 13.7 8.8 136 7 130 165 2.3 0 2.6 2.1 02/11/2007 19:30:00 10.9 0.9 12.6 8.4 10.8 0.9 12.6 8 10.8 0.9 13.3 8 137 5 136 165 2.3 0 2.3 2.1 02/11/2007 19:40:00 10.5 1 13 8 10.4 1 13 8 10.4 0.9 13 8 136 6 135 165 2.3 0 2.8 2.3 02/11/2007 19:50:00 11.6 1 13.7 8.8 11.5 1 13.7 8.8 11.4 1.1 14.1 8.4 136 6 142 165 2.3 0 2.6 2.3 02/11/2007 20:00:00 12.1 1 14.9 9.1 12 1 14.5 9.5 12 1 14.5 8.4 136 6 119 165 2.3 0 2.6 2.1 02/11/2007 20:10:00 11.4 1.2 14.1 8 11.3 1.2 14.1 8.4 11.1 1.1 14.1 8.4 134 8 136 165 2.3 0 2.6 2.1 02/11/2007 20:20:00 12.7 1.1 14.9 9.9 12.5 1.1 14.9 9.5 12.4 1.2 14.9 9.9 137 6 124 165 2.3 0 2.6 2.3 02/11/2007 20:30:00 13.2 0.8 14.9 9.9 13.1 0.8 14.9 10.7 12.9 1 15.3 9.1 135 6 136 165 2.3 0 2.6 2.3 02/11/2007 20:40:00 12.5 1.1 14.5 8.8 12.4 1.1 14.9 9.1 12.3 1.2 14.5 8.4 136 6 126 165 2.3 0 2.6 2.1 02/11/2007 20:50:00 13.3 0.9 15.3 9.5 13.2 0.9 15.3 9.5 12.9 1 15.3 9.9 132 8 125 165 2.2 0 2.6 2.1 02/11/2007 21:00:00 12.8 1.1 15.6 9.5 12.7 1.1 15.6 9.1 12.4 1.2 16.4 9.5 129 9 136 165 2.1 0 2.3 2.1 02/11/2007 21:10:00 12.6 1 14.9 9.9 12.5 1 15.3 9.9 12.2 1.1 15.3 9.1 127 9 112 165 2.1 0 2.6 1.8 02/11/2007 21:20:00 12.1 1 14.9 8.8 12.1 1 14.9 8.8 11.9 1.1 15.3 8.8 129 9 144 165 2.1 0 2.3 1.8 02/11/2007 21:30:00 12.1 1.1 14.9 9.1 12 1.1 15.3 9.5 11.7 1.2 15.3 8.4 130 7 123 165 2.1 0 2.3 1.8 02/11/2007 21:40:00 12.3 1.1 14.9 8.8 12.2 1.1 14.9 8.8 11.8 1.2 14.5 8.8 130 8 135 165 2 0 2.3 1.8 02/11/2007 21:50:00 12.2 1 14.5 9.5 12.2 1 14.5 8.8 11.8 1.2 14.9 8.4 129 9 131 165 2 0 2.3 1.8 02/11/2007 22:00:00 12 1 14.5 8.8 11.9 1 14.1 8.4 11.6 1.2 14.9 7.2 132 8 135 165 2 0 2.3 1.8 02/11/2007 22:10:00 13 0.9 14.9 10.3 12.8 0.9 14.9 10.3 12.6 1 14.9 9.1 134 7 131 165 2.1 0 2.3 1.8 02/11/2007 22:20:00 12.4 1 14.5 9.9 12.3 1 14.5 9.9 12.2 1 14.5 9.1 135 7 138 165 2.1 0 2.3 1.8 02/11/2007 22:30:00 11.3 0.8 13.3 9.5 11.2 0.8 13.7 9.5 11.2 0.8 13.7 9.1 134 9 122 165 2.1 0 2.3 1.8 02/11/2007 22:40:00 12.5 0.9 14.1 9.9 12.4 0.9 14.1 9.5 12.2 1 14.1 8.8 134 6 135 165 2 0 2.8 1.8 02/11/2007 22:50:00 11.8 0.7 13.3 9.9 11.7 0.7 13.3 9.5 11.5 0.8 13 9.1 135 6 135 165 2 0 2.3 1.8 02/11/2007 23:00:00 11.1 0.7 13 9.1 11.1 0.7 12.6 8.8 10.9 0.8 13 8.4 133 7 135 165 2 0 2.3 1.8 02/11/2007 23:10:00 10.6 0.7 12.2 8.4 10.5 0.7 12.2 8.4 10.4 0.7 12.2 8 137 8 128 165 2 0 2.3 1.8 02/11/2007 23:20:00 10.6 0.6 12.2 9.1 10.5 0.6 12.2 8.8 10.5 0.7 12.2 8.8 140 6 141 165 2 0 2.3 1.8 02/11/2007 23:30:00 11.3 1.1 13.3 8.8 11.2 1.1 13.3 8.4 11 1.1 13.7 8 135 6 140 165 2 0 2.3 1.8 02/11/2007 23:40:00 11.4 1 13.3 8.8 11.3 1 13.3 8.4 11.1 1 13.3 8 134 6 126 165 2 0 2.3 1.8 02/11/2007 23:50:00 10.9 0.8 13 8.8 10.9 0.8 13 8.4 10.7 0.8 12.2 7.2 134 8 128 165 2 0 2.3 1.8 02/12/2007 00:00:00 11.5 0.7 13.3 9.5 11.4 0.7 13 9.5 11.3 0.9 13.3 9.1 138 6 141 165 2 0 2.3 1.8 02/12/2007 00:10:00 11 0.7 12.6 9.1 10.9 0.7 12.6 9.1 10.8 0.7 12.6 8.8 136 5 129 165 2 0 2.1 1.8 02/12/2007 00:20:00 9.4 0.8 11.1 6.5 9.3 0.8 11.1 6.8 9 0.9 11.1 6.1 131 8 129 165 2 0 2.3 1.8 02/12/2007 00:30:00 9.6 0.7 11.8 7.2 9.6 0.7 11.5 7.2 9.3 0.8 11.5 5.7 132 8 130 165 2 0 2.3 1.8 02/12/2007 00:40:00 10.1 0.9 12.2 8 10 0.9 12.2 8 10 0.9 12.6 7.2 138 8 140 165 2 0 2.3 1.8 02/12/2007 00:50:00 10.8 0.7 12.2 8.4 10.7 0.7 12.6 8.4 10.6 0.8 12.6 8 131 8 122 165 2 0 2.3 1.8 02/12/2007 01:00:00 10.4 0.8 12.2 8.4 10.3 0.9 12.6 8 10.2 0.9 12.2 7.2 137 6 140 165 2 0 2.3 1.8 02/12/2007 01:10:00 11.5 0.8 13 8 11.4 0.8 13 8 11.2 1 13 8 134 6 137 165 2 0 2.3 1.8 02/12/2007 01:20:00 10.9 0.8 13 9.1 10.8 0.8 13 9.1 10.6 0.7 12.6 8.4 137 6 133 165 2.1 0 2.3 1.8 02/12/2007 01:30:00 10.3 0.8 12.2 8.4 10.3 0.7 12.2 8 10.2 0.7 12.2 7.6 140 5 133 165 2 0 2.3 1.8 02/12/2007 01:40:00 10.8 0.8 13 8.8 10.7 0.8 12.6 8.4 10.6 0.9 13 8.4 139 6 148 165 2 0 2.3 1.8 02/12/2007 01:50:00 11.1 0.8 12.6 8.4 11 0.8 12.2 8 10.8 1 12.6 8 135 6 137 165 2.1 0 2.3 1.8 02/12/2007 02:00:00 11 0.8 13.3 8.8 10.9 0.8 13 8.4 10.8 0.8 12.6 7.2 135 7 136 165 2.1 0 2.3 2.1 02/12/2007 02:10:00 10.4 0.9 12.6 7.6 10.3 0.9 12.6 7.6 10.1 1 12.6 6.8 132 9 137 165 2.1 0 2.3 1.8 02/12/2007 02:20:00 10.8 0.8 12.6 8.8 10.8 0.8 13 8.4 10.5 0.8 12.6 8 132 7 121 165 2.1 0 2.3 2.1 02/12/2007 02:30:00 10.8 1.2 13.3 6.5 10.8 1.3 13.3 6.5 10.3 1.4 13 6.5 129 8 125 165 2.1 0 2.3 2.1 02/12/2007 02:40:00 10.7 1 13.7 7.6 10.6 1 13.3 8 10.3 1.1 13 7.2 130 7 126 165 2.1 0 2.3 1.8 02/12/2007 02:50:00 10.9 0.8 13.3 8.8 10.9 0.8 13.3 8.8 10.7 1 13.7 8 129 8 138 165 2.2 0 2.3 2.1 02/12/2007 03:00:00 9.7 1.2 13.7 6.5 9.7 1.2 13.3 6.8 9.4 1.1 12.2 6.8 129 8 122 165 2.2 0 2.3 2.1 02/12/2007 03:10:00 10 1 12.6 7.6 9.9 1 12.2 7.2 9.8 1 12.2 6.5 132 7 130 165 2.2 0 2.6 2.1 02/12/2007 03:20:00 10.7 1 13 6.8 10.7 1 13 6.8 10.3 1.1 12.6 7.2 126 7 116 165 2.3 0 2.6 2.1 02/12/2007 03:30:00 10.7 1.3 13.7 7.6 10.7 1.3 13.7 8 10.4 1.4 13 7.2 126 6 124 165 2.3 0 2.6 2.1 02/12/2007 03:40:00 10.4 1.1 13.3 7.6 10.4 1.1 13.3 7.6 9.9 1.3 13.3 7.2 128 7 121 165 2.3 0 2.8 2.3 02/12/2007 03:50:00 10.7 0.9 13.3 8.8 10.8 0.9 13.3 8.8 10.4 1 13 8 123 8 121 165 2.3 0 2.6 2.1 02/12/2007 04:00:00 9.6 1 11.8 5.3 9.7 1 11.8 5.7 9.2 1.2 12.2 5.3 119 7 123 165 2.3 0 2.6 2.1 02/12/2007 04:10:00 9.9 0.7 11.8 7.2 10 0.7 11.8 7.6 9.6 0.8 11.5 6.8 121 6 111 165 2.2 0 2.6 2.1 02/12/2007 04:20:00 9.4 1.3 12.6 6.5 9.4 1.3 13 6.5 9.2 1.4 12.6 5.3 125 8 135 165 2.3 0 2.6 2.1 02/12/2007 04:30:00 10 1.4 12.6 6.1 10 1.3 13 6.5 9.5 1.4 12.6 5.7 122 9 116 165 2.2 0 2.6 2.1 02/12/2007 04:40:00 9.9 1.3 13 6.5 10 1.3 12.6 6.5 9.7 1.4 12.6 5.3 126 8 128 165 2.2 0 2.6 2.1 02/12/2007 04:50:00 10.1 1.2 13 7.6 10.2 1.2 12.6 7.6 9.8 1.3 13 6.1 123 8 128 165 2.2 0 2.3 2.1 02/12/2007 05:00:00 8.8 1.1 12.2 6.1 8.8 1.1 11.8 6.1 8.5 1.1 11.8 5.7 130 9 130 165 2.2 0 2.6 2.1 02/12/2007 05:10:00 7.5 0.8 9.9 5.7 7.5 0.7 9.5 5.7 7.3 0.8 9.9 4.2 132 7 127 165 2.1 0 2.3 1.8 02/12/2007 05:20:00 8 0.8 10.3 5.7 8 0.8 10.7 6.1 7.8 0.9 10.3 5.7 133 8 143 165 2 0 2.3 1.8 02/12/2007 05:30:00 8.8 1.2 12.6 5.3 8.8 1.2 12.6 6.1 8.6 1.2 11.8 5.7 136 9 133 165 2 0 2.3 1.8 02/12/2007 05:40:00 8.3 0.7 10.3 6.5 8.2 0.7 10.3 6.5 8 0.7 9.5 5.7 125 8 128 165 2 0 2.3 1.8 02/12/2007 05:50:00 9.7 1.7 13.3 6.1 9.7 1.6 13.3 6.5 9.3 1.7 13 5.7 119 7 121 165 2.1 0 2.3 1.8 02/12/2007 06:00:00 9.9 1.5 13.3 6.1 10 1.5 13.7 6.5 9.5 1.6 13.7 5.7 119 9 108 165 2.1 0 2.3 1.8 02/12/2007 06:10:00 10.4 1.6 14.5 6.8 10.6 1.5 14.9 6.8 10 1.7 14.5 5.7 116 8 110 165 2.1 0 2.3 1.8 02/12/2007 06:20:00 10.9 0.9 13.3 7.6 10.9 0.9 13.3 8 10.6 1 13 8 121 8 115 165 2.1 0 2.3 1.8 02/12/2007 06:30:00 11.2 1.2 14.1 7.6 11.2 1.2 14.5 7.2 10.9 1.3 13.7 6.5 121 7 114 165 2.1 0 2.3 1.8 02/12/2007 06:40:00 10.9 1.1 13.3 7.6 11 1.1 13.7 8 10.7 1.3 13.7 7.6 120 8 121 165 2.1 0 2.3 1.8 02/12/2007 06:50:00 10.8 1.2 13.3 7.2 10.9 1.2 13 7.6 10.3 1.2 13.3 6.8 121 7 111 165 2.1 0 2.3 1.8 02/12/2007 07:00:00 10.9 0.9 14.1 8.8 10.9 0.9 14.1 8.4 10.4 1 13 7.2 123 6 115 165 2.1 0 2.3 1.8 02/12/2007 07:10:00 9.8 0.9 12.6 7.6 9.9 0.9 12.6 7.6 9.5 0.9 12.6 6.8 122 7 104 165 2.1 0 2.3 1.8 02/12/2007 07:20:00 10.9 1.2 13.3 6.5 11 1.2 14.1 6.5 10.4 1.3 13.3 6.1 115 8 112 165 2 0 2.3 1.8 02/12/2007 07:30:00 11.8 1.5 16.1 8 12 1.5 16.1 8.4 11.3 1.5 16.1 8 113 7 105 165 1.9 0 2.3 1.8 02/12/2007 07:40:00 11.1 1.3 14.5 8 11.3 1.3 14.5 7.6 10.4 1.3 13.3 7.2 111 7 104 165 1.9 0 2.1 1.8 02/12/2007 07:50:00 11.1 1.1 14.1 7.2 11.4 1.1 14.5 7.6 10.4 1.2 13 7.2 107 6 114 165 2 0 2.3 1.8 02/12/2007 08:00:00 11.9 1.2 14.5 8.4 12.1 1.2 14.9 8.8 11.3 1.2 14.5 7.6 109 6 99 165 2.1 0 2.3 1.8 02/12/2007 08:10:00 11.1 1.1 13.3 8 11.3 1.1 13.7 8 10.6 1.2 13.3 6.8 111 7 116 165 2.1 0 2.6 1.8 02/12/2007 08:20:00 12.1 1.2 15.3 8 12.3 1.2 15.3 8 11.5 1.4 14.9 7.6 111 7 102 165 2.1 0 2.3 1.8 02/12/2007 08:30:00 12.5 1.3 15.6 8.8 12.6 1.3 15.6 8.8 12 1.5 15.6 8 114 8 128 165 2.1 0 2.6 1.8 02/12/2007 08:40:00 12.3 1.3 15.6 8.8 12.5 1.3 15.6 8.8 11.8 1.2 15.6 8.8 112 6 115 165 2.1 0 2.6 1.8 02/12/2007 08:50:00 11.5 1.3 15.3 7.2 11.7 1.3 15.3 7.6 11 1.4 14.9 7.2 115 7 111 165 2.1 0 2.3 2.1 02/12/2007 09:00:00 11.6 1.2 14.5 8 11.7 1.2 14.1 8 11.1 1.3 14.9 7.2 116 6 125 165 2.1 0 2.3 2.1 02/12/2007 09:10:00 12.5 1.4 15.6 8 12.6 1.4 16.1 8.8 11.9 1.4 14.9 7.2 114 8 110 165 2.1 0 2.3 2.1 02/12/2007 09:20:00 12.1 1.4 16.8 9.1 12.2 1.4 17.2 8.8 11.7 1.4 16.1 8.4 118 7 130 165 2.1 0 2.6 2.1 02/12/2007 09:30:00 11.6 0.9 13.7 9.1 11.7 0.9 14.1 9.1 11.3 1 13.7 8.4 118 6 121 165 2.1 0 2.3 1.8 02/12/2007 09:40:00 12.2 1.1 15.3 8 12.4 1.1 16.1 8.4 11.6 1.5 16.4 6.8 113 7 111 165 2.1 0 2.3 2.1 02/12/2007 09:50:00 11.7 1.5 15.6 8.4 11.9 1.5 15.6 8.4 11.3 1.5 15.6 7.2 115 7 114 165 2.2 0 2.3 2.1 02/12/2007 10:00:00 11.9 1.3 15.6 8.4 12 1.3 15.6 8.4 11.6 1.4 15.3 8 121 7 114 165 2.1 0 2.3 1.8 02/12/2007 10:10:00 11.2 1.7 15.6 8 11.3 1.7 15.6 7.6 10.9 1.7 14.9 7.6 116 9 129 165 2.1 0 2.3 1.8 02/12/2007 10:20:00 11.1 1.5 14.5 8 11.2 1.5 14.9 8.4 10.7 1.5 14.5 7.6 120 7 124 165 2 0 2.3 1.8 02/12/2007 10:30:00 10.6 1.5 14.9 6.8 10.7 1.5 14.9 7.2 10.1 1.3 14.1 6.8 114 9 114 165 2 0 2.3 1.8 02/12/2007 10:40:00 10.6 1.5 14.5 6.8 10.7 1.5 14.5 7.2 10.2 1.5 13.7 6.5 114 8 126 165 2 0 2.3 1.8 02/12/2007 10:50:00 10.6 1.5 14.1 6.5 10.8 1.5 14.5 6.1 10 1.5 14.5 6.5 107 9 92 165 2 0 2.3 1.8 02/12/2007 11:00:00 11.8 1.4 16.4 8.8 12 1.4 16.8 8.8 11 1.5 15.6 6.5 106 7 102 165 2 0 2.3 1.8 02/12/2007 11:10:00 11.6 1.3 14.9 7.2 11.7 1.3 15.3 7.2 10.9 1.5 16.4 7.6 105 6 95 165 2 0 2.3 1.8 02/12/2007 11:20:00 11.8 1.1 15.3 8.4 12 1.1 15.6 8.8 11.3 1.2 14.5 8.4 102 6 102 165 2 0 2.6 1.8 02/12/2007 11:30:00 11.9 1.1 14.9 8.4 12.1 1.1 14.9 8.4 11.2 1.3 14.1 7.6 101 6 106 165 1.9 0 2.6 1.8 02/12/2007 11:40:00 11.1 1.2 13.7 8 11.3 1.2 14.1 8 10.4 1.2 13.3 6.8 101 7 104 165 2 0 2.3 1.8 02/12/2007 11:50:00 11.5 1.1 14.1 8 11.7 1.1 14.1 8 10.8 1.2 13.7 7.2 105 7 96 165 2 0 2.3 1.8 02/12/2007 12:00:00 10.7 1 13.3 8 10.9 1 13.3 8 10.1 1.2 13 7.2 106 7 102 165 2 0 2.3 1.8 02/12/2007 12:10:00 10.7 1.4 14.1 7.6 10.9 1.5 14.5 7.2 10 1.4 13 6.5 101 7 99 165 2 0 2.3 1.8 02/12/2007 12:20:00 11.4 1.5 14.1 6.8 11.6 1.5 14.9 7.2 10.9 1.6 14.1 6.5 98 9 94 165 2 0 2.3 1.8 02/12/2007 12:30:00 10.7 1.2 13.7 8 10.8 1.2 13.7 8 10 1.2 13.3 6.8 102 7 80 165 2 0 2.3 1.8 02/12/2007 12:40:00 11.1 1.5 14.9 6.5 11.3 1.5 15.3 6.8 10.5 1.6 13.7 5.7 100 8 106 165 2 0 2.3 1.8 02/12/2007 12:50:00 11.5 1.7 14.1 6.1 11.7 1.7 14.9 6.5 10.8 1.7 14.9 6.1 99 8 87 165 1.9 0 1.8 1.8 02/12/2007 13:00:00 11.7 1.3 14.9 8 12 1.3 15.3 8 11 1.5 14.1 7.2 95 8 93 165 1.8 0 1.8 1.8 02/12/2007 13:10:00 11.2 1.4 14.5 6.8 11.4 1.5 14.5 7.2 10.5 1.3 13.7 7.2 87 8 87 165 1.8 0 1.8 1.6 02/12/2007 13:20:00 10.8 1 13 7.2 11.1 1 13.7 7.2 10.4 1 13 7.6 84 7 98 165 1.9 0 1.8 1.6 02/12/2007 13:30:00 10.7 1.6 14.5 6.5 11 1.7 14.9 6.5 10.3 1.6 13.7 5.7 82 8 81 165 1.9 0 1.8 1.8 02/12/2007 13:40:00 11.8 1.5 14.9 7.2 12 1.5 15.3 7.6 11.4 1.5 14.9 7.2 84 7 75 165 1.8 0 1.8 1.6 02/12/2007 13:50:00 11.5 1.2 14.1 8 11.7 1.2 14.5 8 11 1.2 13.7 7.2 85 7 78 165 1.8 0 1.8 1.4 02/12/2007 14:00:00 11.6 1.2 14.9 7.2 11.9 1.2 15.3 7.6 11 1.3 14.5 7.2 86 7 86 165 1.8 0 2.1 1.6 02/12/2007 14:10:00 12 1.7 15.3 6.1 12.3 1.7 15.6 6.5 11.5 1.4 15.3 7.2 94 9 100 165 1.8 0 1.8 1.4 02/12/2007 14:20:00 11.3 1.7 15.6 6.8 11.5 1.7 16.4 7.6 10.7 1.7 14.5 6.8 99 9 100 165 1.7 0 1.8 1.1 02/12/2007 14:30:00 11.9 1.6 15.6 7.6 12.2 1.6 16.1 8.4 11 1.6 14.9 7.6 94 8 99 165 1.7 0 1.8 1.6 02/12/2007 14:40:00 12 1.5 14.9 8.4 12.2 1.5 15.3 8 11.2 1.7 14.9 7.2 95 7 96 165 1.7 0 1.8 1.6 02/12/2007 14:50:00 11.1 2.3 17.6 6.5 11.3 2.3 17.6 6.8 10.4 2.3 18.3 6.1 98 8 99 165 1.7 0 1.8 0.9 02/12/2007 15:00:00 11.4 1.7 16.1 6.5 11.6 1.8 16.4 6.8 10.7 1.7 15.3 6.8 98 9 99 165 1.6 0 1.8 1.4 02/12/2007 15:10:00 12.7 1.3 16.1 8.8 13 1.4 16.4 8.8 12.2 1.5 16.1 8.4 88 7 98 165 1.7 0 1.8 1.6 02/12/2007 15:20:00 11.7 1.6 15.6 8 12 1.6 16.1 8 11.2 1.5 15.3 7.2 82 7 74 165 1.7 0 1.8 1.4 02/12/2007 15:30:00 13 1.1 15.6 8.8 13.3 1.2 15.3 9.1 12.3 1.3 14.9 7.6 88 7 87 165 1.7 0 1.8 1.4 02/12/2007 15:40:00 11.5 1.2 14.9 8.4 11.8 1.3 14.9 8 11.1 1.3 14.1 7.6 86 8 98 165 1.6 0 1.8 1.1 02/12/2007 15:50:00 11.7 1.4 14.9 8 12 1.4 15.6 8.4 11.2 1.3 14.5 8 82 8 83 165 1.5 0 1.6 0.9 02/12/2007 16:00:00 10.8 1.3 13.7 7.6 11 1.3 14.1 7.6 10.4 1.3 13.7 7.2 78 7 78 165 1.5 0 1.6 0.9 02/12/2007 16:10:00 9.9 1.4 12.6 6.5 10.2 1.4 13.3 6.8 9.7 1.3 13 6.5 77 6 78 165 1.6 0 1.8 1.4 02/12/2007 16:20:00 10.7 1.2 13.7 7.6 10.9 1.2 14.5 8 10.3 1.2 14.1 7.2 77 6 74 165 1.6 0 1.8 1.4 02/12/2007 16:30:00 10.9 1.5 14.9 6.8 11.1 1.6 14.9 7.2 10.7 1.4 14.5 6.8 75 8 74 165 1.6 0 1.8 1.6 02/12/2007 16:40:00 11 1.5 15.6 7.6 11.3 1.5 16.4 8 10.6 1.3 14.5 7.6 77 6 79 165 1.6 0 1.8 1.6 02/12/2007 16:50:00 10 1.5 13.7 6.5 10.3 1.6 14.1 6.5 9.7 1.4 12.6 6.5 77 6 85 165 1.6 0 1.8 1.6 02/12/2007 17:00:00 10 1.3 13.7 6.8 10.2 1.3 14.1 6.8 9.6 1.2 13.3 6.5 70 7 75 165 1.7 0 1.8 1.6 02/12/2007 17:10:00 10.5 1.1 13.3 7.2 10.7 1.2 13.7 7.6 10.3 1.1 13.7 7.6 59 7 56 165 1.4 0.1 1.8 1.1 02/12/2007 17:20:00 10.4 1.5 14.9 6.8 10.6 1.6 15.3 6.8 10.1 1.5 14.1 6.1 66 10 70 165 1.2 0 1.4 0.9 02/12/2007 17:30:00 10.8 1.5 15.3 7.6 11 1.6 15.3 8 10.4 1.5 14.9 8 71 9 84 165 1.2 0 1.4 0.4 02/12/2007 17:40:00 10.6 1.3 14.1 7.2 10.8 1.3 14.1 7.6 10.5 1.2 13 6.8 66 8 62 165 1.2 0 1.4 0.4 02/12/2007 17:50:00 10.4 2 14.9 6.1 10.7 2.1 15.3 6.1 10.2 1.8 14.5 6.5 71 9 63 165 1.1 0 1.4 0.9 02/12/2007 18:00:00 10.4 1.5 14.9 6.8 10.6 1.6 15.3 6.8 10 1.5 14.5 6.8 73 9 87 165 1.1 0 1.4 0.9 02/12/2007 18:10:00 10.7 1.7 15.3 6.5 10.9 1.8 15.6 7.2 10.3 1.7 13.7 6.5 75 8 84 165 1.1 0 1.4 0.9 02/12/2007 18:20:00 10.8 1.7 14.9 6.8 11.1 1.8 15.3 6.5 10.5 1.5 14.9 7.2 68 8 79 165 1.1 0 1.4 0.7 02/12/2007 18:30:00 10.8 2 16.1 6.1 11 2.1 16.1 5.7 10.4 1.9 16.1 5.7 66 10 80 165 1.1 0 1.4 0.9 02/12/2007 18:40:00 11.3 1.4 14.5 6.5 11.6 1.5 14.9 7.2 11 1.3 14.1 7.6 68 8 63 165 1.1 0 1.4 0.9 02/12/2007 18:50:00 10.5 1.7 15.3 6.1 10.7 1.7 15.6 6.1 10.2 1.5 14.9 6.5 69 8 69 165 1.2 0 1.4 0.9 02/12/2007 19:00:00 11 1.6 15.3 8 11.2 1.7 15.6 8 10.6 1.6 14.5 7.2 68 8 65 165 1.2 0 1.4 1.1 02/12/2007 19:10:00 11 1.7 14.5 7.2 11.1 1.7 14.9 7.2 10.6 1.5 14.1 6.8 59 9 68 165 1.2 0 1.6 0.7 02/12/2007 19:20:00 9.8 1.7 14.1 5.7 9.8 1.8 14.5 5.7 9.4 1.7 13 4.9 52 10 57 165 1.3 0 1.6 0.7 02/12/2007 19:30:00 10 1.8 14.5 6.1 10 1.9 14.9 6.1 9.5 1.7 14.5 5.7 55 10 59 165 1.3 0.1 1.6 0.7 02/12/2007 19:40:00 11.6 2 16.1 6.8 11.7 2.2 16.4 6.5 11 2.1 16.4 6.5 59 9 80 165 1.4 0 1.6 1.4 02/12/2007 19:50:00 12.1 1.7 16.4 8.4 12.2 1.8 16.8 8.8 11.7 1.7 16.1 8 62 8 62 165 1.4 0 1.6 1.4 02/12/2007 20:00:00 11.6 2 16.4 7.2 11.7 2.1 16.4 7.2 11.3 2 16.1 7.2 62 9 63 165 1.4 0 1.6 1.4 02/12/2007 20:10:00 11.9 1.9 17.2 8 11.9 2 17.6 7.6 11.4 2 17.2 7.2 58 8 67 165 1.4 0 1.6 1.1 02/12/2007 20:20:00 12.3 1.9 17.2 8.4 12.3 2.1 17.6 8 11.8 2 16.8 7.2 58 9 59 165 1.4 0 1.6 0.9 02/12/2007 20:30:00 11.6 2 16.1 7.2 11.6 2.1 16.4 7.2 11.1 2 16.8 6.1 53 10 56 165 1.4 0 1.6 1.1 02/12/2007 20:40:00 10.3 1.7 15.3 5.7 10.3 1.7 15.3 5.7 9.7 1.5 14.1 5.7 53 10 58 165 1.4 0 1.6 0.9 02/12/2007 20:50:00 11.4 2.5 16.8 6.1 11.4 2.5 16.8 6.1 10.8 2.3 17.2 6.1 57 9 58 165 1.4 0 1.6 1.4 02/12/2007 21:00:00 11.5 2.1 17.2 6.8 11.6 2.2 17.2 7.2 11 2.1 16.1 6.5 56 9 58 165 1.5 0 1.8 1.4 02/12/2007 21:10:00 11.6 2.2 16.1 5.7 11.6 2.3 16.1 6.1 11.2 2.2 16.1 6.5 57 9 52 165 1.5 0 1.6 1.4 02/12/2007 21:20:00 12.3 1.9 16.8 7.6 12.4 2 17.2 8 12 1.7 17.2 8 57 9 55 165 1.5 0 1.6 1.4 02/12/2007 21:30:00 11.5 1.8 17.2 7.2 11.5 1.8 17.2 6.8 11 1.7 15.6 7.2 54 9 61 165 1.5 0 1.6 1.4 02/12/2007 21:40:00 11.6 1.9 16.4 7.2 11.7 2 16.8 7.2 11.1 2 16.1 6.5 54 11 61 165 1.6 0 1.8 1.4 02/12/2007 21:50:00 11.2 2.1 16.8 7.2 11.2 2.2 17.6 7.2 11 1.8 16.4 7.6 50 10 68 165 1.7 0 1.8 1.6 02/12/2007 22:00:00 12.4 2.6 18.7 5.7 12.4 2.6 19.1 5.7 11.7 2.6 18.3 5.7 54 11 60 165 1.7 0 1.8 1.6 02/12/2007 22:10:00 12 2.5 17.9 6.8 12.2 2.7 18.7 6.8 11.7 2.6 17.6 7.6 56 9 56 165 1.8 0 1.8 1.6 02/12/2007 22:20:00 12.4 2.1 17.6 7.2 12.5 2.3 18.7 6.8 12 2.3 18.7 6.8 57 10 52 165 1.9 0 2.1 1.8 02/12/2007 22:30:00 12.5 2 18.3 8 12.6 2.1 19.1 7.6 12.2 1.8 17.9 7.6 59 9 54 165 2 0 2.3 1.8 02/12/2007 22:40:00 12.7 1.7 17.6 8.4 12.8 1.8 17.6 8.4 12.5 1.8 18.3 8.4 59 9 59 165 2 0 2.3 1.8 02/12/2007 22:50:00 12.8 1.7 17.9 9.1 13 1.9 18.7 9.1 12.6 1.7 17.6 8.4 68 9 54 165 2.1 0 2.3 2.1 02/12/2007 23:00:00 11.7 1.4 16.8 8.8 11.9 1.5 17.2 8.8 11.4 1.5 16.4 7.6 71 10 76 165 2.2 0 2.3 2.1 02/12/2007 23:10:00 12.3 1.7 16.1 8 12.5 1.7 16.8 8 11.9 1.6 16.1 6.5 75 9 56 165 2 0.1 2.6 1.8 02/12/2007 23:20:00 12.6 1.3 16.1 9.1 12.9 1.4 16.8 8.8 12 1.3 15.3 9.5 76 8 79 165 1.9 0 2.1 1.6 02/12/2007 23:30:00 11.7 1.5 15.6 8.4 11.9 1.6 16.1 8.4 11.3 1.5 15.6 7.6 70 9 81 165 1.8 0 1.8 1.6 02/12/2007 23:40:00 11.7 1.7 15.6 8 11.8 1.7 15.6 8 11.4 1.7 15.6 7.6 71 8 82 165 1.8 0 1.8 1.6 02/12/2007 23:50:00 11.9 1.6 15.6 8.4 12.1 1.7 16.4 8.4 11.5 1.6 15.6 8 70 8 85 165 1.8 0 1.8 1.6 02/13/2007 00:00:00 13.6 1.4 17.2 10.3 13.8 1.5 17.6 10.3 13.1 1.3 16.8 9.5 75 7 82 165 1.8 0 1.8 1.4 02/13/2007 00:10:00 10.9 1.6 14.9 7.6 11 1.7 14.9 8 10.6 1.5 15.3 7.6 65 9 73 165 1.8 0 1.8 1.4 02/13/2007 00:20:00 12.2 2 16.8 6.8 12.3 2.1 16.8 6.8 11.7 1.9 15.6 6.5 66 9 84 165 1.7 0.1 1.8 1.4 02/13/2007 00:30:00 12.6 1.5 16.8 8.8 12.8 1.7 17.2 8.4 11.9 1.5 15.6 8 63 8 65 165 1.8 0.1 1.8 1.4 02/13/2007 00:40:00 12 1.8 15.3 6.8 12.1 1.9 16.1 6.5 11.6 1.8 15.6 6.8 63 9 80 165 2 0 2.3 1.6 02/13/2007 00:50:00 12.6 1.8 17.6 8 12.9 1.9 17.9 8.4 12.2 1.8 18.3 8.4 70 8 77 165 2 0 2.3 1.8 02/13/2007 01:00:00 11.6 1.7 16.1 7.6 11.8 1.9 16.4 7.6 11.2 1.8 16.1 7.6 61 9 73 165 2.1 0 2.3 1.6 02/13/2007 01:10:00 11.9 1.9 17.6 6.8 12.1 2 18.3 7.2 11.6 1.9 17.6 6.8 62 10 68 165 2.1 0 2.3 1.6 02/13/2007 01:20:00 12.4 2 16.4 5.7 12.6 2.1 17.2 6.1 12.1 2 16.8 6.8 62 9 73 165 2.1 0 2.3 1.6 02/13/2007 01:30:00 12.2 1.8 17.2 8 12.5 1.9 17.9 8 12 1.8 17.6 8 65 9 57 165 2.1 0 2.3 1.6 02/13/2007 01:40:00 11.6 2.2 17.9 5.3 11.8 2.3 18.3 5.7 11.2 2.1 16.8 6.5 65 9 69 165 2.1 0 2.3 1.6 02/13/2007 01:50:00 11.6 1.7 16.8 7.6 11.8 1.8 17.2 7.2 11.4 1.6 15.3 7.2 64 9 78 165 2.1 0 2.3 1.6 02/13/2007 02:00:00 12.1 2 17.2 7.2 12.2 2 17.6 7.2 11.8 1.9 17.9 6.8 60 9 63 165 2.2 0 2.3 1.6 02/13/2007 02:10:00 13.6 1.7 17.6 9.1 13.8 1.8 17.9 9.1 13.2 1.7 17.2 8.4 66 8 68 165 2.1 0 2.3 1.6 02/13/2007 02:20:00 12.1 1.5 17.2 8.8 12.3 1.6 17.6 8.8 11.8 1.6 17.2 8.4 64 9 50 165 2.2 0 2.6 1.8 02/13/2007 02:30:00 11.8 1.5 14.9 8 11.9 1.6 15.6 7.6 11.3 1.5 14.9 8 59 8 70 165 2.1 0 2.3 1.8 02/13/2007 02:40:00 9.7 1.4 13.7 6.5 9.8 1.5 13.7 6.1 9.4 1.5 14.1 6.1 57 9 53 165 2.1 0 2.3 1.8 02/13/2007 02:50:00 10.8 1.6 14.5 6.1 10.9 1.6 14.9 6.5 10.4 1.6 14.5 5.7 54 11 43 165 2.1 0 2.3 1.8 02/13/2007 03:00:00 10.5 1.7 15.3 6.1 10.6 1.7 15.3 6.1 10.2 1.6 14.1 6.1 51 9 39 165 2 0 2.3 1.8 02/13/2007 03:10:00 10.3 1.5 14.1 7.2 10.5 1.5 14.5 6.8 10.2 1.5 14.5 7.2 57 10 50 165 2.1 0 2.3 1.8 02/13/2007 03:20:00 10.6 1.9 14.5 5.7 10.7 2 14.9 5.7 10.2 1.9 14.9 5.3 53 9 56 165 2 0 2.3 1.8 02/13/2007 03:30:00 10.5 2.1 14.9 5.7 10.6 2.2 15.3 6.1 10.2 2.1 14.9 5.3 57 10 56 165 1.9 0 2.3 1.8 02/13/2007 03:40:00 11 1.6 14.9 7.2 11.1 1.7 15.3 7.2 10.6 1.7 16.4 6.8 55 9 52 165 1.9 0 2.1 1.6 02/13/2007 03:50:00 11 1.7 15.3 6.5 11.2 1.8 15.6 6.8 10.6 1.8 15.3 6.8 54 9 61 165 1.9 0 2.1 1.6 02/13/2007 04:00:00 10.2 1.7 14.1 5.7 10.1 1.7 13.7 5.7 9.7 1.5 13.7 5.7 54 9 47 165 1.9 0 1.8 1.6 02/13/2007 04:10:00 8.8 1.5 13 5.3 8.7 1.5 13 5.3 8.4 1.3 13 4.9 49 10 50 165 1.9 0 2.1 1.8 02/13/2007 04:20:00 8.2 1.7 12.2 4.2 8.2 1.7 12.6 4.2 7.9 1.5 11.8 4.2 50 10 66 165 1.9 0 2.3 1.8 02/13/2007 04:30:00 8.8 1.7 12.6 4.6 8.9 1.7 13 4.6 8.5 1.7 12.6 4.9 56 10 63 165 2.1 0 2.3 1.4 02/13/2007 04:40:00 11 1.7 15.3 6.5 11 1.7 14.9 6.5 10.5 1.7 14.1 6.5 71 8 73 165 2.3 0 2.6 2.1 02/13/2007 04:50:00 10.2 1.5 13.7 6.1 10.4 1.5 13.7 6.1 9.9 1.5 13.3 6.5 74 8 73 165 2.4 0 2.6 2.1 02/13/2007 05:00:00 10.1 1.3 13 7.2 10.4 1.4 13.7 7.2 9.9 1.3 13 6.8 80 8 83 165 2.4 0 2.8 2.3 02/13/2007 05:10:00 11.2 1.5 14.5 7.2 11.7 1.6 15.3 7.6 10.7 1.5 14.1 6.5 89 8 98 165 2.4 0 2.8 2.3 02/13/2007 05:20:00 10.9 1 13.3 7.6 11.4 1 13.7 7.6 10.6 1.1 13.3 7.2 98 7 84 165 2.3 0 2.6 2.3 02/13/2007 05:30:00 9.1 1 11.8 6.8 9.5 0.9 12.2 6.8 8.9 1 11.5 6.5 101 7 106 165 2.3 0 2.6 2.1 02/13/2007 05:40:00 8.7 0.9 10.7 5.7 9 0.9 11.5 5.7 8.4 0.8 10.3 5.7 96 7 101 165 2.3 0 2.6 2.1 02/13/2007 05:50:00 6.4 1 8.8 4.2 6.7 1 9.5 4.9 6.3 1 9.1 4.2 93 6 100 165 2.2 0 2.6 2.1 02/13/2007 06:00:00 7.3 1.3 9.9 3.8 7.6 1.4 10.3 4.2 7 1.4 9.5 3.8 86 8 79 165 2.4 0 2.6 2.3 02/13/2007 06:10:00 8.4 0.9 10.7 6.1 8.7 1 11.1 6.5 8 0.9 10.7 5.7 87 8 87 165 2.6 0 2.8 2.6 02/13/2007 06:20:00 9.7 1.5 12.6 5.3 10.1 1.6 13 5.7 9.3 1.5 13 6.5 87 8 81 165 2.9 0 3.3 2.8 02/13/2007 06:30:00 9.6 1.5 12.6 5.3 9.9 1.6 13.3 4.9 9.2 1.5 12.2 5.3 88 10 89 165 3 0 3.5 2.8 02/13/2007 06:40:00 11.6 0.8 13.3 9.1 12 0.9 13.7 9.1 11.2 1 13 8 91 5 84 165 3 0 3.8 2.8 02/13/2007 06:50:00 11.6 0.7 13.7 9.5 11.9 0.8 14.1 9.5 11.2 1 13.3 8.4 91 5 94 165 3 0 3.3 2.8 02/13/2007 07:00:00 11.6 0.7 13.3 9.5 11.9 0.8 13.7 9.5 11.1 1 13 8 94 5 94 165 3 0 3.3 2.8 02/13/2007 07:10:00 10.4 0.7 12.6 7.6 10.7 0.8 13 7.6 9.7 1 11.8 7.2 97 5 94 165 3 0 3.3 2.8 02/13/2007 07:20:00 10 0.7 11.8 7.2 10.3 0.7 12.2 7.6 9.5 0.8 11.1 6.8 97 5 104 165 3 0 3.3 2.8 02/13/2007 07:30:00 10 0.8 12.2 7.6 10.3 0.8 12.6 7.6 9.4 0.9 11.5 6.8 101 4 98 165 3 0 3.5 2.8 02/13/2007 07:40:00 9.8 0.8 12.2 6.8 10.1 0.8 12.2 7.2 9.3 1 12.2 7.2 98 5 99 165 3.1 0 3.5 3 02/13/2007 07:50:00 9.7 1 11.8 6.5 10 1 12.2 6.8 9.3 1 11.8 6.1 103 5 110 165 3 0 3.5 2.8 02/13/2007 08:00:00 8.7 0.8 10.7 5.7 8.9 0.8 10.7 6.1 8.3 0.9 10.7 6.1 104 5 110 165 3.2 0 3.5 3 02/13/2007 08:10:00 8.4 0.8 9.9 5.7 8.6 0.8 9.9 5.7 7.9 1 9.9 4.9 98 5 98 165 3.2 0 3.5 3 02/13/2007 08:20:00 8.6 0.8 10.7 6.8 8.9 0.8 10.7 6.8 8.2 0.9 10.3 5.3 95 6 90 165 3.2 0 3.5 3 02/13/2007 08:30:00 9.6 1 11.8 6.8 9.9 1 12.2 7.6 9.2 1 11.5 6.8 89 6 87 165 3.2 0 3.5 3 02/13/2007 08:40:00 10 0.6 11.8 8 10.3 0.6 11.8 8.4 9.6 0.8 11.1 7.2 89 4 81 165 3.2 0 3.8 3.3 02/13/2007 08:50:00 9.6 0.7 11.5 8 9.9 0.7 11.8 6.8 9.3 0.9 11.1 6.5 91 6 84 165 3.2 0 3.5 3 02/13/2007 09:00:00 7.9 1 10.3 4.9 8.1 1 10.3 5.3 7.6 1 9.9 4.9 97 6 102 165 3.2 0 3.3 3 02/13/2007 09:10:00 7.2 0.7 8.4 4.9 7.4 0.6 8.8 5.3 7 0.7 8.4 4.9 87 7 91 165 3 0.1 3.3 2.8 02/13/2007 09:20:00 6.7 0.7 8.4 4.9 6.9 0.7 8.4 4.9 6.5 0.8 8 4.9 82 5 84 165 2.9 0 3 2.6 02/13/2007 09:30:00 6.4 0.5 7.6 4.9 6.7 0.5 7.6 5.3 6.3 0.5 7.6 4.9 85 4 87 165 2.9 0 3 2.8 02/13/2007 09:40:00 6.4 0.6 8 4.2 6.6 0.7 8 4.6 6.2 0.6 7.6 4.2 82 5 78 165 2.9 0 3.5 2.8 02/13/2007 09:50:00 5.9 0.5 6.8 4.6 6.1 0.6 7.2 4.6 5.7 0.6 6.8 3.8 80 5 74 165 2.9 0 3 2.8 02/13/2007 10:00:00 5.5 0.5 6.8 4.2 5.7 0.5 6.5 3.8 5.3 0.6 6.5 3.4 91 6 106 165 2.9 0 3 2.8 02/13/2007 10:10:00 5.6 0.4 6.5 4.6 5.8 0.4 6.8 4.6 5.3 0.6 6.8 3.8 97 4 103 165 3 0 3.3 2.8 02/13/2007 10:20:00 4.9 0.4 5.7 4.2 5 0.4 6.1 4.2 4.7 0.5 6.1 3 105 8 102 165 3 0 3.3 2.8 02/13/2007 10:30:00 4.7 0.4 5.7 3.8 4.7 0.4 5.7 3.8 4.5 0.4 5.3 3.4 118 6 120 165 3 0 3.3 2.8 02/13/2007 10:40:00 5.5 0.5 6.8 4.6 5.4 0.5 6.8 4.2 5.2 0.5 6.5 4.2 128 5 134 165 3 0 3.5 2.8 02/13/2007 10:50:00 7.2 0.7 8.4 4.6 7 0.6 8.4 5.3 6.8 0.8 8.4 4.2 138 7 135 165 3 0 3.3 2.8 02/13/2007 11:00:00 7.8 0.5 8.8 6.5 7.5 0.4 8.4 6.1 7.6 0.5 8.8 6.1 152 5 155 165 2.6 0.2 3 2.3 02/13/2007 11:10:00 6.9 0.7 8.4 4.9 6.6 0.7 8 4.6 6.7 0.7 8 4.9 153 3 151 165 2.4 0 2.6 2.3 02/13/2007 11:20:00 5.5 0.7 6.8 4.2 5.2 0.7 6.5 3.8 5.2 0.8 6.5 3.8 153 3 153 165 2.4 0 2.6 2.3 02/13/2007 11:30:00 5 0.3 5.7 3.8 4.7 0.3 5.3 3.8 4.5 0.3 5.3 3.8 152 3 154 165 2.4 0 2.8 2.3 02/13/2007 11:40:00 4.7 0.5 5.7 2.6 4.5 0.5 5.7 2.6 4.3 0.5 5.3 3 150 4 149 165 2.7 0 2.8 2.6 02/13/2007 11:50:00 5.3 0.6 6.8 2.6 5.1 0.5 6.5 3 5.1 0.6 6.5 3 148 6 150 165 2.9 0 3.3 2.6 02/13/2007 12:00:00 6.2 0.8 8 4.6 6 0.8 8 4.6 6.1 0.8 8.4 4.2 146 6 144 165 2.9 0 3.3 2.8 02/13/2007 12:10:00 6.6 0.6 7.6 5.3 6.4 0.6 7.6 4.9 6.5 0.6 7.6 4.6 150 4 145 165 2.9 0 3 2.8 02/13/2007 12:20:00 6.2 0.4 7.2 4.9 5.9 0.4 6.8 4.6 6 0.4 6.8 4.9 153 4 154 165 3 0 3.3 2.8 02/13/2007 12:30:00 6.5 0.4 7.6 5.3 6.2 0.4 7.6 5.3 6.5 0.4 8 5.3 156 5 153 165 2.9 0 3 2.8 02/13/2007 12:40:00 6.5 0.5 8 5.3 6.3 0.5 7.6 4.9 6.4 0.5 7.6 5.3 157 6 156 165 2.9 0 3.5 2.6 02/13/2007 12:50:00 7.7 0.6 9.1 6.1 7.5 0.6 9.1 5.7 7.7 0.6 9.5 6.1 156 11 167 165 2.7 0 2.8 2.6 02/13/2007 13:00:00 8.7 1.2 11.1 6.1 8.3 1.1 10.7 5.7 8.7 1.2 11.5 6.1 158 15 172 165 2.8 0 3 2.6 02/13/2007 13:10:00 9.8 0.8 11.8 7.6 9.4 0.7 11.1 7.6 9.8 0.8 11.8 7.6 170 13 169 165 2.7 0 3 2.6 02/13/2007 13:20:00 10.9 0.9 12.6 8.4 10.4 0.8 11.8 8 10.8 1 12.6 8 172 10 179 165 2.8 0 3 2.6 02/13/2007 13:30:00 11.2 0.8 13 9.5 10.6 0.7 12.2 8.8 11.3 0.7 13 9.5 172 13 185 165 2.6 0.2 2.8 2.1 02/13/2007 13:40:00 10.7 0.5 11.8 9.5 10.2 0.5 11.5 8.8 10.9 0.6 12.2 9.1 169 12 169 165 2.2 0 2.6 1.8 02/13/2007 13:50:00 10.4 0.6 11.8 8.8 9.9 0.5 11.1 8.4 10.6 0.6 12.2 8.8 168 15 179 165 2 0 2.3 1.8 02/13/2007 14:00:00 10.5 0.6 12.2 8.4 10 0.5 11.8 8.8 10.6 0.6 12.2 8.8 166 13 171 165 2 0 2.3 1.8 02/13/2007 14:10:00 10.6 0.7 12.6 8 10.1 0.6 11.8 8 10.7 0.7 12.2 8.4 169 21 167 165 2.3 0 2.6 2.1 02/13/2007 14:20:00 11 0.6 12.6 9.5 10.6 0.6 12.2 9.1 11.2 0.5 12.6 9.1 164 21 166 165 2 0.2 2.6 1.6 02/13/2007 14:30:00 11.8 0.8 13.7 9.9 11.4 0.7 13 9.5 12.1 0.8 14.1 9.5 167 15 168 165 2 0 2.3 1.8 02/13/2007 14:40:00 11.3 0.7 12.6 8.8 10.8 0.7 12.2 8 11.4 0.7 13 9.5 166 18 165 165 2.1 0 2.3 1.8 02/13/2007 14:50:00 10.9 1 12.6 8 10.4 0.8 12.2 7.6 11 1 12.6 8 170 9 169 165 2.1 0 2.3 1.8 02/13/2007 15:00:00 10.4 0.5 11.8 8.4 9.9 0.5 11.1 8.4 10.4 0.7 11.8 8.4 169 10 165 165 2.2 0 2.6 1.8 02/13/2007 15:10:00 10 0.6 11.5 8 9.6 0.5 10.7 7.6 10.2 0.6 11.8 8.8 167 8 165 165 1.9 0 2.3 1.8 02/13/2007 15:20:00 9.8 0.6 11.1 8 9.4 0.5 10.3 7.6 10.1 0.6 11.5 8.4 167 12 168 165 2 0 2.3 1.8 02/13/2007 15:30:00 9.4 0.7 10.7 8 9 0.7 10.3 7.6 9.5 0.9 11.1 7.6 168 15 169 165 1.9 0.1 2.3 1.6 02/13/2007 15:40:00 8.8 0.5 9.9 7.2 8.3 0.5 9.9 6.8 9 0.5 9.9 7.2 170 14 171 165 1.8 0 2.3 1.6 02/13/2007 15:50:00 9.5 0.3 10.3 8.4 9 0.3 9.5 8 9.8 0.4 10.7 8.8 167 9 175 165 1.7 0 1.8 1.4 02/13/2007 16:00:00 9.2 0.5 10.3 7.6 8.7 0.5 9.9 7.2 9.4 0.6 10.7 7.2 172 6 173 165 1.7 0 1.8 1.4 02/13/2007 16:10:00 8.9 0.6 10.3 7.2 8.5 0.6 9.9 6.8 9.1 0.6 10.3 7.6 172 5 181 165 1.7 0.1 2.1 1.1 02/13/2007 16:20:00 6.7 1 8.8 4.6 6.5 0.9 8.4 4.6 6.9 1 9.1 4.6 180 9 171 165 1.7 0 1.8 1.1 02/13/2007 16:30:00 5.3 0.5 6.5 3.8 5.1 0.5 6.5 3.4 5.6 0.6 6.8 3.8 183 6 195 165 1.7 0 1.8 1.4 02/13/2007 16:40:00 6 0.5 7.6 4.6 5.7 0.5 7.2 4.6 6.2 0.6 7.6 4.6 173 17 179 165 2 0 2.3 1.6 02/13/2007 16:50:00 5.8 0.8 8 3.8 5.6 0.8 8 3.4 5.7 0.8 8.4 3.4 188 10 200 165 2.1 0 2.3 2.1 02/13/2007 17:00:00 7.6 0.9 9.5 5.7 7.4 0.9 9.1 5.7 7.6 0.8 9.5 5.7 187 9 193 165 1.8 0.2 2.3 1.4 02/13/2007 17:10:00 7.5 0.7 8.8 5.3 7.3 0.6 8.8 5.3 7.7 0.7 9.1 6.1 189 6 193 165 1.4 0 1.6 1.4 02/13/2007 17:20:00 7.2 0.7 9.5 5.3 6.9 0.7 8.8 4.9 7.2 0.6 9.1 5.7 182 6 184 165 1.4 0 1.6 1.1 02/13/2007 17:30:00 8.2 0.6 9.9 6.5 7.8 0.5 9.1 6.1 8.2 0.6 9.5 6.5 181 5 177 165 1.4 0.1 1.6 0.9 02/13/2007 17:40:00 7.3 0.6 8.4 5.7 7 0.6 8 5.3 7.3 0.6 8.4 5.3 180 5 182 165 1.4 0 1.6 1.1 02/13/2007 17:50:00 6.1 0.4 7.2 5.3 5.8 0.4 6.8 4.9 6.1 0.4 7.6 4.9 169 11 178 165 1.2 0 1.4 0.9 02/13/2007 18:00:00 5.9 0.4 6.8 4.9 5.6 0.4 6.5 4.9 6 0.4 6.8 4.6 166 15 172 165 1.2 0 1.4 0.9 02/13/2007 18:10:00 5.8 0.7 7.2 4.2 5.5 0.6 6.5 3.8 5.8 0.6 7.2 4.6 169 12 165 165 1.2 0 1.4 0.9 02/13/2007 18:20:00 7 0.6 8.8 5.3 6.6 0.6 8 5.3 7 0.7 8.4 5.3 166 16 172 165 1.2 0 1.4 0.9 02/13/2007 18:30:00 7.4 0.6 8.8 6.1 7 0.5 8.4 5.7 7.5 0.5 8.8 6.1 163 12 164 165 1.2 0 1.4 0.7 02/13/2007 18:40:00 6.9 0.5 8 5.7 6.6 0.4 7.6 5.3 6.9 0.5 8 5.7 167 8 169 165 1.2 0 1.4 0.9 02/13/2007 18:50:00 7.6 0.6 9.1 6.1 7.2 0.5 8.4 6.1 7.7 0.5 9.1 6.1 167 8 169 165 1.2 0 1.4 0.9 02/13/2007 19:00:00 8.9 0.8 10.7 6.8 8.5 0.7 10.3 6.8 9 0.8 10.7 7.2 170 13 165 165 1.2 0 1.4 0.9 02/13/2007 19:10:00 8.1 0.7 9.5 6.8 7.7 0.6 9.1 6.5 8.2 0.7 9.9 6.8 171 6 167 165 1.2 0 1.4 0.9 02/13/2007 19:20:00 6.8 0.5 8.4 5.7 6.5 0.5 7.6 5.3 6.9 0.5 8 5.7 174 5 144 165 1.2 0 1.4 0.9 02/13/2007 19:30:00 6.2 0.5 7.2 4.6 5.9 0.5 6.8 4.6 6.1 0.6 7.2 4.6 178 3 178 165 1.1 0 1.4 0.7 02/13/2007 19:40:00 5.2 0.5 6.5 3.8 5 0.4 6.1 3.8 5.3 0.5 6.5 4.2 172 9 176 165 1.1 0 1.4 0.7 02/13/2007 19:50:00 4 0.8 6.1 2.6 3.8 0.8 5.7 2.6 3.9 0.8 6.5 2.3 172 10 162 165 1.1 0 1.4 0.9 02/13/2007 20:00:00 3.8 0.6 5.3 2.3 3.6 0.6 4.9 2.3 3.7 0.5 4.9 2.3 177 10 179 165 1 0 1.4 0.7 02/13/2007 20:10:00 4 0.6 5.3 2.3 3.8 0.6 5.3 2.3 3.9 0.5 5.3 3 171 12 176 165 1 0 1.4 0.7 02/13/2007 20:20:00 3.3 0.6 4.9 1.9 3.1 0.6 4.6 1.9 3.2 0.6 4.6 1.5 177 8 177 165 1.1 0 1.4 0.9 02/13/2007 20:30:00 3.9 0.8 6.5 2.3 3.7 0.8 6.1 1.9 3.7 0.7 5.7 2.3 185 10 193 165 1.1 0 1.4 0.9 02/13/2007 20:40:00 3.4 0.5 4.6 1.9 3.3 0.5 4.6 1.9 3.2 0.5 4.6 1.9 198 5 191 165 1.1 0 1.4 0.7 02/13/2007 20:50:00 5 0.8 6.5 3 4.8 0.8 6.1 2.6 4.8 0.8 6.5 2.6 189 4 187 165 1.1 0 1.4 0.7 02/13/2007 21:00:00 5.7 0.6 7.2 4.2 5.5 0.5 6.8 4.2 5.7 0.6 7.2 4.6 185 4 184 165 1.2 0.1 1.6 0.9 02/13/2007 21:10:00 6.2 0.5 7.6 4.9 6 0.5 7.2 4.6 6.2 0.5 7.6 4.9 186 4 182 165 1.4 0 1.6 1.4 02/13/2007 21:20:00 5.7 0.5 7.2 4.6 5.6 0.5 6.8 4.2 5.7 0.5 6.8 4.6 191 5 189 165 1.2 0 1.4 0.9 02/13/2007 21:30:00 5.2 0.5 6.8 4.2 5.2 0.4 6.5 4.2 5.3 0.4 6.5 4.2 193 4 191 165 1.1 0 1.4 0.9 02/13/2007 21:40:00 4.2 0.4 5.3 3 4.2 0.4 5.3 3 4.3 0.5 5.3 3 194 4 196 165 1.1 0 1.4 0.9 02/13/2007 21:50:00 3.7 0.4 4.9 2.6 3.6 0.5 4.6 2.6 3.6 0.4 4.6 2.3 193 6 176 165 1.1 0 1.4 0.9 02/13/2007 22:00:00 3.6 0.5 4.9 2.3 3.6 0.5 4.9 2.3 3.5 0.5 4.9 2.6 196 3 197 165 1 0 1.4 0.4 02/13/2007 22:10:00 4.3 0.3 4.9 3.4 4.2 0.3 4.9 3 4.2 0.4 4.9 3 187 6 193 165 1 0 1.1 0.4 02/13/2007 22:20:00 3.9 0.5 4.9 2.6 3.7 0.5 4.6 2.6 3.7 0.4 4.6 2.6 169 5 165 165 0.9 0 1.1 0.9 02/13/2007 22:30:00 3.8 0.7 5.7 2.3 3.6 0.7 5.3 1.9 3.6 0.6 5.7 2.3 170 5 171 165 0.9 0 1.1 0.2 02/13/2007 22:40:00 5.1 0.9 6.8 2.3 4.8 0.8 6.5 2.3 4.9 0.8 6.5 2.6 171 7 174 165 0.8 0.1 0.9 0.2 02/13/2007 22:50:00 7.2 0.9 9.5 4.9 6.8 0.8 8.8 4.6 7 0.9 9.5 4.6 173 5 178 165 0.8 0 0.9 0.7 02/13/2007 23:00:00 7.8 0.5 8.8 6.5 7.4 0.4 8.4 6.5 7.9 0.4 8.8 6.8 173 5 166 165 0.8 0 0.9 0.7 02/13/2007 23:10:00 7 0.8 9.1 5.3 6.8 0.7 9.1 4.9 7 0.8 9.5 5.3 176 7 172 165 0.8 0 0.9 0.7 02/13/2007 23:20:00 7.4 0.9 9.1 5.3 7.1 0.8 8.8 4.9 7.4 0.8 9.1 5.3 178 4 172 165 0.8 0 0.9 0.7 02/13/2007 23:30:00 6.5 0.6 7.6 4.6 6.3 0.5 7.2 4.6 6.6 0.5 8 4.9 181 2 181 165 0.8 0.1 1.1 0.2 02/13/2007 23:40:00 7.2 0.3 8 6.1 6.9 0.3 7.6 6.1 7.3 0.3 8 6.1 180 4 182 165 0.9 0 1.1 0.7 02/13/2007 23:50:00 6.7 0.6 7.6 4.9 6.4 0.5 7.6 4.9 6.8 0.5 8 5.7 166 4 172 165 0.8 0.1 1.1 0.2 02/14/2007 00:00:00 6.4 0.4 7.2 5.3 6.1 0.4 6.8 4.9 6.5 0.5 7.6 5.3 166 5 162 165 0.8 0 1.1 0.7 02/14/2007 00:10:00 5 0.6 6.1 3.8 5 0.6 6.1 3.8 5.2 0.6 6.8 4.2 169 13 163 165 0.8 0 0.9 0.7 02/14/2007 00:20:00 4.6 0.4 5.7 3.4 4.5 0.4 5.7 3.4 4.6 0.5 5.7 3.4 170 5 165 165 0.8 0 0.9 0.7 02/14/2007 00:30:00 5.3 0.5 6.5 4.2 5 0.5 6.1 3.8 5.1 0.5 6.5 3.8 167 13 172 165 0.7 0 0.9 0.4 02/14/2007 00:40:00 6.1 0.5 7.2 4.9 5.7 0.5 6.8 4.2 6 0.5 7.2 4.9 169 4 168 165 0.8 0 0.9 0.7 02/14/2007 00:50:00 5.6 0.5 6.8 4.6 5.4 0.4 6.5 4.6 5.7 0.5 7.2 4.6 170 5 169 165 0.8 0 0.9 0.2 02/14/2007 01:00:00 4.8 0.5 6.1 3.8 4.5 0.5 5.7 3.8 4.7 0.4 5.7 3.8 169 4 165 165 0.8 0.1 1.1 0.2 02/14/2007 01:10:00 4.5 0.6 6.8 3.4 4.3 0.6 6.5 3 4.5 0.6 6.5 3.4 166 5 172 165 0.9 0 1.1 0.7 02/14/2007 01:20:00 4.4 0.6 5.7 3.4 4.1 0.6 5.7 3 4.2 0.6 6.5 3 167 4 164 165 0.8 0.1 1.1 0.7 02/14/2007 01:30:00 4.3 0.5 5.3 2.6 4.3 0.5 5.7 3 4.5 0.5 6.1 3 167 6 183 165 0.9 0 1.4 0.2 02/14/2007 01:40:00 3.7 0.4 4.6 2.6 3.5 0.4 4.6 2.6 3.5 0.4 4.6 2.6 169 7 165 165 0.9 0 1.1 0.7 02/14/2007 01:50:00 4.1 0.8 5.7 2.3 3.8 0.7 5.3 1.9 4.1 0.8 5.7 2.3 166 4 168 165 0.8 0 1.1 0.7 02/14/2007 02:00:00 3.3 0.5 4.6 2.3 3.1 0.5 4.2 1.9 3.3 0.4 4.2 2.6 171 4 172 165 0.9 0.1 1.1 0.7 02/14/2007 02:10:00 3.7 0.6 5.3 2.6 3.5 0.5 4.9 2.3 3.6 0.5 4.9 2.6 175 5 174 165 0.8 0 0.9 0.7 02/14/2007 02:20:00 3.3 0.4 4.2 2.3 3.1 0.4 4.2 2.3 3.2 0.4 4.2 2.3 177 5 178 165 0.9 0 1.1 0.4 02/14/2007 02:30:00 4.1 0.6 5.7 3 4 0.6 6.1 3 3.9 0.6 5.7 3 169 6 165 165 0.9 0 1.1 0.9 02/14/2007 02:40:00 4.6 0.7 6.5 3 4.5 0.7 6.1 2.6 4.6 0.8 6.1 2.6 163 7 165 165 0.9 0 1.1 0.9 02/14/2007 02:50:00 5.9 1 8 4.2 5.7 1 7.6 4.2 5.9 1 8 3.8 162 8 174 165 0.8 0 1.1 0.7 02/14/2007 03:00:00 6.6 0.6 8 4.9 6.4 0.6 7.6 4.9 6.7 0.6 8 5.3 168 9 162 165 0.8 0 1.1 0.4 02/14/2007 03:10:00 5.8 0.9 7.6 3.8 5.5 0.8 7.2 3.8 5.9 0.9 8 3.8 172 5 169 165 0.8 0 0.9 0.7 02/14/2007 03:20:00 3.9 0.4 4.9 2.6 3.8 0.4 5.3 2.3 4.1 0.5 5.3 2.3 171 5 164 165 0.8 0 0.9 0.7 02/14/2007 03:30:00 3.9 0.4 4.9 3 3.6 0.4 4.6 2.6 3.7 0.4 4.9 2.6 167 7 163 165 0.7 0 0.9 0.4 02/14/2007 03:40:00 3.1 0.6 4.2 1.5 2.9 0.6 4.2 0.4 3.2 0.4 4.2 1.9 154 10 161 165 0.7 0 0.9 0.4 02/14/2007 03:50:00 3.9 0.5 5.3 2.6 3.6 0.5 4.9 2.3 3.6 0.5 4.9 2.6 163 14 167 165 0.6 0 0.9 0.4 02/14/2007 04:00:00 3.4 0.5 4.6 1.9 3.2 0.5 4.6 1.9 3.2 0.5 4.2 1.9 161 5 159 165 0.7 0 0.9 0.4 02/14/2007 04:10:00 2.2 0.5 3.8 0.7 1.9 0.7 3.4 0.4 2.2 0.5 3.4 0.7 161 10 141 165 0.7 0 0.9 0.4 02/14/2007 04:20:00 2.6 0.4 3.4 1.5 2.3 0.4 3 1.1 2.5 0.4 3.4 1.5 163 10 165 165 0.5 0 0.9 -0.1 02/14/2007 04:30:00 2.9 0.4 3.8 1.9 2.5 0.4 3.4 1.5 2.5 0.4 3.4 1.5 163 5 171 165 0.5 0 0.7 0.2 02/14/2007 04:40:00 3 0.5 4.2 1.9 2.7 0.6 4.2 1.1 2.8 0.6 4.2 1.5 157 8 148 165 0.4 0 0.7 0.2 02/14/2007 04:50:00 3.7 0.5 4.9 3 3.6 0.4 4.9 3 3.7 0.4 4.6 3 151 5 151 165 0.4 0 0.7 0.2 02/14/2007 05:00:00 3.1 0.5 4.6 1.9 2.9 0.6 4.2 1.1 3.2 0.5 4.6 1.9 162 6 156 165 0.5 0 0.7 -0.1 02/14/2007 05:10:00 2.9 0.4 3.8 1.9 2.8 0.5 3.8 1.5 2.9 0.4 3.8 1.9 147 16 165 165 0.5 0 0.7 0.2 02/14/2007 05:20:00 3.2 0.4 4.2 1.9 3.1 0.4 4.2 1.9 3.1 0.4 4.2 1.9 143 10 142 165 0.5 0 0.7 0.4 02/14/2007 05:30:00 2.9 0.4 4.2 2.3 2.8 0.4 3.8 1.9 2.9 0.4 4.2 2.3 152 10 135 165 0.5 0 0.9 0.2 02/14/2007 05:40:00 2.9 0.4 3.8 2.3 2.7 0.4 3.8 1.9 2.8 0.4 3.8 1.9 140 8 146 165 0.5 0 0.7 0.2 02/14/2007 05:50:00 3.6 0.3 4.6 3 3.5 0.3 4.2 2.6 3.6 0.3 4.2 2.6 139 5 146 165 0.7 0 0.9 0.4 02/14/2007 06:00:00 3.5 0.3 4.2 3 3.4 0.3 4.2 2.6 3.5 0.2 4.2 2.6 140 3 144 165 0.7 0 0.9 0.4 02/14/2007 06:10:00 3.4 0.3 4.2 2.6 3.3 0.3 4.2 2.6 3.4 0.3 4.2 2.6 141 3 141 165 0.7 0 0.9 0.4 02/14/2007 06:20:00 3.3 0.3 4.2 2.6 3.2 0.3 3.8 2.3 3.2 0.2 3.8 2.6 143 4 143 165 0.7 0 0.9 0.7 02/14/2007 06:30:00 2.7 0.5 3.8 1.5 2.7 0.6 3.8 1.5 2.7 0.5 3.8 1.5 138 5 141 165 0.7 0 0.9 0.4 02/14/2007 06:40:00 2 0.4 2.6 1.1 1.9 0.4 2.6 0.7 1.9 0.3 2.6 1.1 139 6 138 165 0.5 0 0.9 0.2 02/14/2007 06:50:00 2.1 0.4 3 1.5 2.1 0.4 3 1.1 2.1 0.3 3 1.5 143 4 137 165 0.5 0 0.7 0.2 02/14/2007 07:00:00 2 0.4 3 1.1 1.9 0.4 2.6 1.1 2 0.3 2.6 1.1 147 3 148 165 0.5 0 0.7 0.2 02/14/2007 07:10:00 1.5 0.5 2.6 0.4 1.4 0.6 2.6 0.4 1.3 0.5 2.3 0.4 151 6 151 165 0.5 0 0.7 0.4 02/14/2007 07:20:00 0.6 0.4 1.5 0.4 0.5 0.3 1.5 0.4 0.5 0.3 1.5 0.4 144 1 142 165 0.6 0 0.9 0.4 02/14/2007 07:30:00 0.7 0.5 2.3 0.4 0.6 0.5 2.3 0.4 0.5 0.4 1.9 0.4 143 3 135 165 0.6 0 0.9 0.4 02/14/2007 07:40:00 1 0.6 2.6 0.4 0.9 0.6 2.6 0.4 0.8 0.5 2.3 0.4 142 5 135 165 0.6 0 0.9 0.4 02/14/2007 07:50:00 1.2 0.7 3 0.4 1.2 0.7 3 0.4 1.1 0.6 2.3 0.4 130 10 145 165 0.6 0 0.9 0.2 02/14/2007 08:00:00 1.2 0.5 2.6 0.4 1.3 0.6 2.6 0.4 0.9 0.6 2.3 0.4 129 14 117 165 0.5 0 0.9 0.2 02/14/2007 08:10:00 1.5 0.4 2.6 0.7 1.5 0.4 2.6 0.4 1.3 0.4 2.6 0.4 148 5 153 165 0.5 0 0.9 0.2 02/14/2007 08:20:00 1.4 0.4 2.6 0.4 1.4 0.4 2.6 0.4 1.5 0.3 2.3 0.7 136 7 128 165 0.3 0.1 0.7 -0.1 02/14/2007 08:30:00 1.3 0.6 2.6 0.4 1.1 0.6 2.6 0.4 1.2 0.5 2.3 0.4 137 5 130 165 0.2 0.1 0.7 -0.3 02/14/2007 08:40:00 1.8 0.5 2.6 0.4 1.6 0.5 3 0.4 1.8 0.5 3 0.7 147 8 134 165 0.2 0.1 0.7 -0.5 02/14/2007 08:50:00 2.6 0.5 3.4 1.1 2.5 0.6 3.8 0.7 2.5 0.5 3.4 1.1 153 6 164 165 0.2 0.1 0.4 -0.3 02/14/2007 09:00:00 3.5 0.5 4.9 2.6 3.4 0.5 4.9 2.3 3.5 0.5 4.6 2.6 154 6 160 165 0.2 0 0.4 -0.1 02/14/2007 09:10:00 3.1 0.5 4.2 1.9 2.9 0.5 3.8 1.9 2.9 0.4 4.2 1.5 159 4 161 165 0.2 0 0.4 -0.1 02/14/2007 09:20:00 3.1 0.5 4.2 1.9 2.8 0.6 3.8 1.5 2.8 0.5 4.2 1.9 161 3 163 165 0.2 0 0.4 0.2 02/14/2007 09:30:00 2.7 0.4 4.2 1.5 2.4 0.4 3.8 1.1 2.5 0.4 3.4 1.5 149 8 134 165 0.2 0.1 0.7 -0.3 02/14/2007 09:40:00 3.1 0.5 4.2 2.3 2.9 0.5 3.8 1.9 2.9 0.5 3.8 1.9 160 4 160 165 0.5 0 0.9 0.2 02/14/2007 09:50:00 3.1 0.3 4.2 2.3 2.9 0.4 3.8 2.3 3 0.4 3.8 1.9 156 3 153 165 0.7 0.1 0.9 0.4 02/14/2007 10:00:00 3 0.6 4.2 1.5 2.8 0.6 4.2 1.5 3 0.6 4.2 1.5 155 7 151 165 0.8 0 1.1 0.7 02/14/2007 10:10:00 3.2 0.4 4.2 1.9 3.2 0.5 4.2 1.9 3.2 0.5 3.8 0.7 138 8 138 165 1.1 0.2 1.4 0.7 02/14/2007 10:20:00 3.2 0.3 3.8 2.6 3.1 0.3 3.8 2.3 3 0.3 3.8 1.9 135 3 136 165 1.4 0 1.6 1.4 02/14/2007 10:30:00 3.4 0.5 4.2 1.9 3.3 0.6 4.2 1.9 3.2 0.5 4.2 1.9 135 5 136 165 1.5 0 1.6 1.4 02/14/2007 10:40:00 3.3 0.4 4.6 2.3 3.3 0.4 4.6 2.3 3.2 0.4 4.6 1.9 130 11 128 165 1.7 0.2 2.6 1.4 02/14/2007 10:50:00 3.8 0.7 5.3 1.9 3.8 0.7 4.9 1.9 3.7 0.6 4.9 2.3 128 8 128 165 2 0 2.3 1.8 02/14/2007 11:00:00 4.1 0.6 5.7 2.6 4.1 0.6 5.7 2.6 3.9 0.6 5.3 2.3 121 7 124 165 1.6 0.2 2.3 1.4 02/14/2007 11:10:00 3.6 0.4 4.6 2.6 3.6 0.4 4.6 2.3 3.5 0.4 4.6 2.6 120 6 127 165 1.4 0 1.6 1.4 02/14/2007 11:20:00 3.1 0.5 4.2 1.9 3.1 0.5 4.2 1.9 2.9 0.5 3.8 1.9 124 6 138 165 1.4 0 1.6 1.4 02/14/2007 11:30:00 3.1 0.4 4.2 2.3 3.1 0.4 4.2 2.3 2.8 0.4 3.8 1.5 129 8 125 165 1.4 0 1.6 1.4 02/14/2007 11:40:00 4.5 1.1 6.8 2.6 4.6 1 6.8 3 4.6 1.1 6.8 2.6 140 9 147 165 1.3 0 1.6 0.9 02/14/2007 11:50:00 5.9 0.7 7.2 3.8 5.7 0.6 7.2 3.8 6 0.7 7.6 4.2 157 5 153 165 0.9 0.1 1.4 0.7 02/14/2007 12:00:00 4.2 0.6 5.7 3 4.2 0.5 5.7 3 4.5 0.6 6.1 3 162 5 165 165 0.8 0 0.9 0.7 02/14/2007 12:10:00 2.5 0.5 3.8 1.5 2.5 0.4 3.8 1.5 2.9 0.4 4.2 2.3 163 1 164 165 0.8 0 0.9 0.7 02/14/2007 12:20:00 2.4 0.4 3.8 1.5 2.4 0.4 3.8 1.5 2.5 0.4 3.8 1.1 146 22 124 165 0.9 0 1.1 0.7 02/14/2007 12:30:00 3 0.5 4.2 1.1 3 0.6 4.2 1.1 3 0.6 4.9 1.5 136 12 125 165 1.2 0 1.4 0.9 02/14/2007 12:40:00 2.9 0.4 3.8 1.5 2.8 0.4 3.8 1.9 2.9 0.4 3.8 1.1 134 8 128 165 0.9 0 1.4 0.9 02/14/2007 12:50:00 1.9 0.3 2.6 1.5 1.7 0.3 2.6 0.7 1.9 0.4 3 1.1 142 8 119 165 1.1 0 1.6 0.9 02/14/2007 13:00:00 2.6 0.4 3.8 1.5 2.4 0.4 3.4 1.5 2.5 0.4 3.4 1.5 160 3 164 165 0.9 0.1 1.4 0.7 02/14/2007 13:10:00 2.6 0.6 3.8 0.4 2.4 0.6 3.8 0.4 2.6 0.6 3.8 0.7 152 15 153 165 0.9 0 1.4 0.7 02/14/2007 13:20:00 1.7 0.6 3 0.4 1.5 0.7 3 0.4 1.5 0.6 2.6 0.4 128 15 123 165 1.4 0 1.6 1.4 02/14/2007 13:30:00 2 0.5 3 0.7 2 0.5 3.4 0.7 1.9 0.6 3.4 0.7 108 17 94 165 1.4 0 1.6 1.4 02/14/2007 13:40:00 2.1 0.9 4.6 0.4 2.1 1 4.6 0.4 2.1 0.8 4.2 0.4 99 23 111 165 1.4 0 1.6 1.4 02/14/2007 13:50:00 2.1 0.6 3 0.4 2 0.6 3.4 0.4 2 0.6 3 0.4 73 29 74 165 1.2 0 1.6 0.9 02/14/2007 14:00:00 1.7 0.9 3.8 0.4 1.6 0.9 3.8 0.4 1.6 0.8 3 0.4 88 20 87 165 1.1 0 1.4 0.9 02/14/2007 14:10:00 1.9 0.6 3.8 0.4 1.8 0.7 3.8 0.4 1.7 0.7 3 0.4 138 12 118 165 0.9 0 1.1 0.7 02/14/2007 14:20:00 2 0.5 3.4 0.7 1.9 0.5 3 0.4 2 0.4 3 1.1 104 5 109 165 1.1 0.2 1.6 0.7 02/14/2007 14:30:00 2.2 0.5 3.4 0.7 2.1 0.6 3.4 0.4 2.1 0.6 3.4 0.4 115 5 116 165 1.4 0 1.6 1.4 02/14/2007 14:40:00 2.4 0.5 3.4 1.1 2.3 0.6 3.4 0.7 2.2 0.6 3.8 0.4 112 1 111 165 1.4 0 1.6 1.4 02/14/2007 14:50:00 1.7 0.4 2.6 0.7 1.6 0.5 2.6 0.4 1.6 0.6 2.6 0.4 113 1 113 165 1.4 0 1.6 1.4 02/14/2007 15:00:00 1.4 0.5 3 0.7 1.1 0.6 3 0.4 1.1 0.5 2.6 0.4 112 2 111 165 1.4 0 1.6 1.1 02/14/2007 15:10:00 1.6 0.5 2.6 0.4 1.5 0.6 3 0.4 1.4 0.5 2.3 0.4 112 1 113 165 1.1 0 1.4 0.4 02/14/2007 15:20:00 2.7 0.7 4.2 0.7 2.6 0.8 4.2 0.4 2.7 0.8 4.2 0.7 111 1 112 165 1.1 0 1.4 0.9 02/14/2007 15:30:00 2.6 0.6 3.8 1.1 2.6 0.6 3.8 1.1 2.6 0.7 4.2 1.1 111 1 112 165 1.1 0 1.4 0.7 02/14/2007 15:40:00 3 1 5.3 0.7 2.9 1 4.9 0.7 3 0.8 4.9 1.1 86 23 72 165 1.2 0 1.4 0.9 02/14/2007 15:50:00 3 0.6 4.6 1.9 3 0.6 4.6 1.5 3 0.6 4.6 1.9 70 11 74 165 1.2 0 1.4 0.9 02/14/2007 16:00:00 3 0.6 4.6 1.5 2.9 0.6 4.6 1.1 2.9 0.5 4.2 1.1 70 12 74 165 1.3 0.1 1.4 0.9 02/14/2007 16:10:00 3 0.6 4.2 1.5 2.9 0.6 4.2 1.5 2.9 0.5 4.2 1.9 57 6 62 165 1.2 0 1.4 0.7 02/14/2007 16:20:00 2.2 0.6 3.8 1.1 2.1 0.7 3.8 0.7 2.1 0.6 3.4 0.7 70 9 60 165 1.2 0 1.4 0.9 02/14/2007 16:30:00 1.9 0.8 3.8 0.4 1.6 0.9 3.8 0.4 1.5 0.9 3.4 0.4 44 10 23 165 1.2 0 1.4 0.7 02/14/2007 16:40:00 2.2 0.5 3.4 0.4 2.1 0.5 3.4 0.4 2.2 0.5 3.8 1.1 66 12 60 165 1.1 0 1.4 0.9 02/14/2007 16:50:00 3.9 1.1 5.7 1.1 3.9 1.2 5.3 0.7 3.8 1 5.3 1.1 79 9 88 165 0.8 0.1 1.1 0.2 02/14/2007 17:00:00 5.1 0.6 6.5 3.8 5.2 0.6 6.5 3.4 4.9 0.6 6.5 3.4 86 4 87 165 0.5 0.1 0.9 -0.1 02/14/2007 17:10:00 4.2 0.8 5.7 2.6 4.3 0.8 6.1 3 4.2 0.6 5.3 3 91 8 100 165 0.5 0.1 0.9 -0.1 02/14/2007 17:20:00 3.8 0.7 5.7 2.6 3.9 0.7 5.7 2.6 3.8 0.6 5.3 2.3 81 13 70 165 0.5 0.2 0.9 0.2 02/14/2007 17:30:00 4.1 0.6 5.7 2.6 4.2 0.6 5.7 2.6 4 0.6 5.7 2.6 72 8 84 165 0.5 0.1 0.9 0.2 02/14/2007 17:40:00 3.8 0.7 5.7 1.9 3.8 0.7 5.3 2.3 3.7 0.6 5.3 2.3 73 9 67 165 0.7 0.1 0.9 0.2 02/14/2007 17:50:00 3.7 0.5 5.3 2.3 3.7 0.5 5.3 2.3 3.5 0.5 4.6 2.3 64 8 58 165 0.7 0 0.9 0.2 02/14/2007 18:00:00 3.6 0.6 5.3 1.9 3.6 0.7 5.3 1.9 3.5 0.6 4.9 1.9 61 7 63 165 0.5 0.1 0.9 0.2 02/14/2007 18:10:00 3.7 0.4 4.6 2.6 3.8 0.4 4.6 2.6 3.6 0.4 4.6 2.6 68 4 63 165 0.2 0.3 0.7 -0.3 02/14/2007 18:20:00 4 0.4 4.9 2.6 4.1 0.4 4.9 3 3.9 0.4 4.9 3 65 5 77 165 0.4 0 0.7 0.2 02/14/2007 18:30:00 4 0.6 5.3 2.6 4.1 0.6 5.7 2.6 3.7 0.6 5.7 2.3 62 6 63 165 0.4 0.1 0.7 -0.1 02/14/2007 18:40:00 4.2 0.5 5.7 3.4 4.3 0.5 5.7 3 4 0.5 4.9 3 74 8 75 165 0.5 0.1 0.9 0.2 02/14/2007 18:50:00 5.1 0.7 6.5 3.4 5.2 0.7 6.8 3.4 5 0.7 6.5 3.4 75 9 80 165 0.7 0 0.9 0.2 02/14/2007 19:00:00 4.3 0.5 5.7 3 4.5 0.5 5.7 2.6 4.2 0.5 5.3 2.6 74 8 81 165 0.8 0 0.9 0.4 02/14/2007 19:10:00 4.7 0.4 5.7 3.8 4.8 0.4 5.7 3.8 4.4 0.4 5.3 3.8 77 5 77 165 0.8 0.1 1.1 0.2 02/14/2007 19:20:00 4.8 0.5 5.7 3.8 4.9 0.5 5.7 3.4 4.6 0.5 5.7 3.4 75 4 74 165 0.8 0.1 0.9 0.2 02/14/2007 19:30:00 4.2 0.5 5.3 3 4.4 0.4 5.3 3.4 4.1 0.4 4.9 2.6 66 5 59 165 0.8 0 1.1 0.7 02/14/2007 19:40:00 4.5 0.5 5.7 3 4.7 0.5 5.7 3.4 4.4 0.5 5.7 3 75 5 78 165 0.8 0 1.1 0.7 02/14/2007 19:50:00 3.6 0.6 4.9 2.3 3.8 0.5 5.3 2.3 3.7 0.5 4.9 2.6 62 7 59 165 0.9 0 1.1 0.7 02/14/2007 20:00:00 4.3 0.3 5.3 3.4 4.5 0.3 5.3 3.8 4.2 0.4 5.3 3 58 4 55 165 0.8 0 1.1 0.9 02/14/2007 20:10:00 4.1 0.5 5.3 2.6 4.2 0.5 5.3 2.6 4 0.5 4.9 2.6 57 5 57 165 0.9 0 1.1 0.9 02/14/2007 20:20:00 4.8 0.4 6.1 3.8 5 0.4 6.1 3.8 4.5 0.4 5.7 3.4 55 4 50 165 0.9 0 1.1 0.9 02/14/2007 20:30:00 4.4 0.3 5.3 3.8 4.6 0.3 5.3 3.8 4.3 0.3 5.3 3.4 58 3 54 165 0.9 0 1.1 0.9 02/14/2007 20:40:00 4.5 0.3 5.3 3.4 4.6 0.3 5.3 3.8 4.4 0.3 5.3 3.8 58 3 54 165 0.8 0 1.1 0.7 02/14/2007 20:50:00 4.7 0.6 6.1 3.4 4.8 0.5 6.1 3.4 4.4 0.4 5.7 3.4 71 6 64 165 0.9 0 1.4 0.9 02/14/2007 21:00:00 5.5 0.5 6.5 4.2 5.6 0.5 6.5 4.2 5.2 0.5 6.1 4.2 75 5 80 165 1.1 0 1.4 0.9 02/14/2007 21:10:00 4.8 0.5 6.1 3.4 4.9 0.5 6.1 3.8 4.6 0.6 6.1 3.4 68 5 69 165 1.1 0 1.4 0.9 02/14/2007 21:20:00 4.8 0.7 6.5 3.4 4.9 0.7 6.5 3.4 4.6 0.7 6.1 3 67 7 67 165 1.1 0 1.4 0.9 02/14/2007 21:30:00 4.9 0.4 6.1 3.8 5.1 0.4 6.5 3.8 4.8 0.4 5.7 3.8 66 4 73 165 1 0 1.4 0.9 02/14/2007 21:40:00 5.1 0.4 6.1 3.8 5.3 0.4 6.5 3.8 5 0.4 5.7 3.8 68 4 63 165 0.8 0.2 1.1 0.2 02/14/2007 21:50:00 5.2 0.2 5.7 4.6 5.4 0.2 5.7 4.6 5.2 0.3 5.7 3.8 77 3 80 165 0.6 0.1 0.9 0.2 02/14/2007 22:00:00 4.7 0.3 5.7 4.2 4.8 0.3 5.7 4.2 4.8 0.3 5.7 4.2 71 2 74 165 0.6 0 0.9 -0.1 02/14/2007 22:10:00 4.4 0.2 4.9 3.8 4.6 0.3 4.9 4.2 4.5 0.2 4.9 3.8 66 3 68 165 0.5 0 0.9 0.2 02/14/2007 22:20:00 4.4 0.2 4.9 3.8 4.6 0.2 4.9 4.2 4.4 0.2 4.9 3.8 56 3 55 165 0.7 0.1 0.9 0.2 02/14/2007 22:30:00 4 0.4 4.9 3 4.1 0.4 4.9 3 3.6 0.5 4.9 2.6 47 5 52 165 0.7 0.2 0.9 0.2 02/14/2007 22:40:00 3.4 0.3 4.2 2.6 3.4 0.3 4.2 2.6 3.2 0.3 3.8 2.6 40 4 50 165 0.7 0 0.9 0.2 02/14/2007 22:50:00 3.6 0.3 4.2 3 3.6 0.3 4.2 2.6 3.2 0.3 4.2 2.3 45 4 37 165 0.7 0 0.9 0.7 02/14/2007 23:00:00 3.5 0.4 4.2 2.6 3.5 0.4 4.2 2.6 3.1 0.4 4.2 2.3 51 5 52 165 0.8 0.1 0.9 0.2 02/14/2007 23:10:00 3.3 0.3 4.2 2.6 3.3 0.3 4.2 2.6 3.2 0.3 4.2 2.6 37 4 37 165 0.8 0.1 0.9 0.2 02/14/2007 23:20:00 3.5 0.3 4.6 3 3.5 0.3 4.2 2.6 3.5 0.2 4.2 2.6 32 4 37 165 0.8 0 0.9 0.4 02/14/2007 23:30:00 4 0.3 4.9 3.4 4 0.3 4.6 3.4 3.9 0.3 4.6 3.4 31 3 34 165 0.8 0 0.9 0.7 02/14/2007 23:40:00 3.9 0.2 4.6 3.4 3.9 0.2 4.6 3.4 4.2 0.2 4.9 3.8 22 1 23 165 0.7 0 0.9 0.4 02/14/2007 23:50:00 4.1 0.3 4.9 3.4 4.1 0.3 4.9 3 4.3 0.3 4.9 3 20 2 21 165 0.7 0 0.9 0.4 02/15/2007 00:00:00 4.1 0.4 5.3 3.4 4.2 0.3 5.3 3.4 4.1 0.4 5.3 3 28 5 29 165 0.8 0 0.9 0.7 02/15/2007 00:10:00 4.1 0.4 4.9 2.6 4.1 0.5 4.9 3 4.1 0.5 5.3 3 31 5 34 165 0.8 0 0.9 0.7 02/15/2007 00:20:00 3.4 0.5 4.2 1.9 3.3 0.5 4.2 1.5 3.1 0.6 4.2 1.5 33 7 21 165 0.8 0 1.1 0.7 02/15/2007 00:30:00 3.5 0.3 4.6 2.6 3.5 0.4 4.6 2.6 3.4 0.3 4.6 2.6 37 5 49 165 0.8 0 0.9 0.7 02/15/2007 00:40:00 3.8 0.3 4.6 3 3.7 0.3 4.6 3 3.7 0.3 4.2 2.6 29 4 29 165 0.8 0 0.9 0.4 02/15/2007 00:50:00 3.8 0.3 4.6 3.4 3.8 0.3 4.6 3.4 3.8 0.2 4.2 3 29 2 29 165 0.7 0 0.9 0.2 02/15/2007 01:00:00 3.7 0.3 4.6 2.6 3.6 0.4 4.6 2.6 3.7 0.4 4.6 2.6 32 5 39 165 0.8 0 0.9 0.2 02/15/2007 01:10:00 3.6 0.3 4.2 3 3.5 0.3 4.2 2.6 3.4 0.3 4.2 2.6 35 4 31 165 0.8 0 0.9 0.7 02/15/2007 01:20:00 3.3 0.2 3.8 3 3.2 0.2 3.8 2.6 3.1 0.3 3.8 2.6 37 3 34 165 0.8 0 0.9 0.7 02/15/2007 01:30:00 3 0.3 3.8 2.3 2.8 0.3 3.4 1.9 2.7 0.3 3.4 1.9 35 3 36 165 0.8 0 0.9 0.7 02/15/2007 01:40:00 3 0.2 3.4 2.6 2.8 0.2 3.4 2.3 2.8 0.2 3.4 2.3 34 2 37 165 0.8 0 1.1 0.4 02/15/2007 01:50:00 3.1 0.6 4.9 1.9 3 0.6 4.6 1.9 2.7 0.7 4.6 1.1 51 13 41 165 0.8 0 1.1 0.4 02/15/2007 02:00:00 4.3 0.6 5.7 2.3 4.3 0.7 5.7 2.3 4.1 0.7 6.1 2.3 32 9 35 165 0.8 0 0.9 0.7 02/15/2007 02:10:00 4.2 0.5 5.3 3 4.3 0.6 5.3 3 4.2 0.5 5.3 2.6 34 5 31 165 0.8 0.1 1.1 0.4 02/15/2007 02:20:00 3.9 0.3 4.6 3 4.1 0.3 4.9 3 3.9 0.3 4.6 2.6 31 3 31 165 0.6 0 0.9 0.2 02/15/2007 02:30:00 3.8 0.3 4.6 3 4 0.3 4.9 3 3.9 0.3 4.9 3 28 3 29 165 0.7 0 0.9 0.2 02/15/2007 02:40:00 4.2 0.2 4.9 3.4 4.4 0.3 5.3 3.8 4.5 0.3 4.9 3.8 27 2 26 165 0.7 0 0.9 -0.1 02/15/2007 02:50:00 4.2 0.3 4.6 3.4 4.3 0.3 4.9 3.4 4.3 0.4 4.9 3.4 24 3 29 165 0.7 0.1 0.9 0.2 02/15/2007 03:00:00 3.6 0.4 4.2 2.6 3.5 0.5 4.2 2.3 3.5 0.5 4.2 2.3 32 5 27 165 0.7 0.1 0.9 0.2 02/15/2007 03:10:00 4.4 0.5 5.7 3.4 4.5 0.5 5.7 3.4 4.3 0.5 5.3 3.4 23 3 20 165 0.7 0.2 0.9 -0.1 02/15/2007 03:20:00 5.1 0.4 6.1 3.8 4.9 0.6 6.1 2.6 5 0.5 6.1 3.4 19 3 23 165 0.7 0.1 0.9 0.2 02/15/2007 03:30:00 4.7 0.6 6.8 3.4 4.6 0.8 6.5 2.6 4.6 0.7 6.8 2.6 21 7 31 165 0.8 0.1 0.9 0.2 02/15/2007 03:40:00 5 0.5 6.5 3.8 5.1 0.5 6.5 3.8 4.9 0.6 6.5 3.4 37 4 37 165 0.7 0 0.9 -0.1 02/15/2007 03:50:00 5.1 0.5 6.5 4.2 5.2 0.5 6.5 4.2 5.1 0.6 6.1 3.8 31 4 31 165 0.6 0 0.9 0.2 02/15/2007 04:00:00 3.7 0.5 4.9 1.9 3.8 0.6 5.3 1.9 3.6 0.7 5.3 1.9 31 3 25 165 0.5 0 0.7 0.2 02/15/2007 04:10:00 4.9 0.5 6.1 3.8 4.8 0.5 6.5 3 4.7 0.6 6.5 3.4 26 7 34 165 0.5 0 0.9 0.2 02/15/2007 04:20:00 4.9 0.7 6.5 3 4.4 0.7 6.5 2.6 4.8 0.7 6.1 2.6 21 12 18 165 0.8 0.1 1.1 0.4 02/15/2007 04:30:00 4.9 0.7 6.5 3 5.1 0.7 6.5 3 4.9 0.7 6.5 2.6 34 9 35 165 0.7 0.2 0.9 0.2 02/15/2007 04:40:00 5.1 0.5 6.5 3.4 4.9 0.7 6.5 3 4.9 0.5 6.5 3.4 21 5 19 165 0.7 0.1 0.9 -0.1 02/15/2007 04:50:00 4.6 0.6 5.7 3 4.5 0.6 6.1 2.6 4.4 0.6 5.7 3 22 6 25 165 0.7 0.1 0.9 -0.1 02/15/2007 05:00:00 4.8 0.6 6.5 3 4.4 0.8 6.8 2.3 4.6 0.6 6.5 3 20 8 28 165 0.7 0.2 0.9 0.2 02/15/2007 05:10:00 5.5 0.6 6.8 3.8 5 1.1 6.8 2.3 5.2 0.8 6.8 3.4 16 7 19 165 0.8 0.1 0.9 -0.1 02/15/2007 05:20:00 3.8 0.9 5.7 1.9 3.6 0.9 5.3 1.5 3.6 0.9 5.3 1.5 23 6 28 165 0.8 0.1 0.9 0.2 02/15/2007 05:30:00 3.7 0.6 4.9 2.3 3.4 0.6 4.6 1.9 3.5 0.6 4.9 1.1 19 6 18 165 0.8 0.1 1.1 0.2 02/15/2007 05:40:00 3.7 0.7 5.3 2.3 3.4 0.8 5.3 1.1 3.3 0.7 4.9 1.1 23 9 20 165 0.8 0.1 0.9 0.2 02/15/2007 05:50:00 3.7 0.6 5.7 2.3 3.4 0.6 5.7 1.9 3.4 0.7 5.3 1.9 24 10 30 165 0.8 0.1 1.1 0.2 02/15/2007 06:00:00 4.5 0.9 6.8 2.3 4.4 1 6.8 2.3 4.2 0.9 6.5 1.9 28 8 36 165 0.8 0.1 1.1 0.2 02/15/2007 06:10:00 3 0.3 3.8 1.9 3 0.4 3.8 1.9 2.7 0.4 3.8 1.1 44 7 34 165 0.8 0.1 0.9 0.2 02/15/2007 06:20:00 3.7 0.7 4.9 1.9 3.5 0.7 4.9 1.9 3.5 0.8 4.9 1.5 36 12 25 165 0.8 0.1 1.1 0.2 02/15/2007 06:30:00 2.9 0.7 4.6 1.5 2.8 0.8 4.6 1.1 2.5 0.8 4.6 0.7 37 11 32 165 0.8 0.1 0.9 0.2 02/15/2007 06:40:00 4.3 0.5 5.3 2.6 4.4 0.5 5.3 2.6 4.2 0.6 5.3 1.9 33 6 26 165 0.8 0.1 0.9 -0.1 02/15/2007 06:50:00 3.5 0.5 4.9 2.3 3.4 0.5 4.9 1.9 3.4 0.5 4.6 1.9 37 5 32 165 0.7 0 0.9 0.4 02/15/2007 07:00:00 2.9 0.6 4.6 1.1 2.9 0.6 4.6 1.1 2.5 0.6 4.6 0.4 50 8 48 165 0.7 0 0.9 0.4 02/15/2007 07:10:00 3.1 0.4 4.2 1.9 3 0.4 4.2 1.9 2.8 0.4 3.8 1.5 42 5 44 165 0.7 0 0.9 0.2 02/15/2007 07:20:00 2.8 0.3 3.4 1.9 2.7 0.3 3.4 1.9 2.5 0.4 3 1.1 40 0 41 165 0.7 0.1 0.9 0.2 02/15/2007 07:30:00 3.4 0.4 4.2 2.3 3.3 0.5 4.2 2.3 3.2 0.5 4.6 2.3 24 6 21 165 0.8 0 0.9 0.7 02/15/2007 07:40:00 3.2 0.3 4.2 2.3 3.1 0.3 4.2 2.3 2.9 0.5 4.2 1.5 21 0 22 165 0.8 0 0.9 0.7 02/15/2007 07:50:00 2.9 0.7 4.2 1.1 2.9 0.7 4.2 1.1 2.5 0.9 4.2 0.4 21 0 22 165 0.8 0 0.9 0.7 02/15/2007 08:00:00 2.6 1 4.2 0.7 2.6 1 4.2 0.7 2.1 1.3 4.2 0.4 21 0 22 165 0.8 0 0.9 0.7 02/15/2007 08:10:00 3 0.5 4.2 1.9 3 0.4 4.2 1.9 2.9 0.5 4.2 1.5 31 13 22 165 0.8 0 0.9 0.7 02/15/2007 08:20:00 3.2 0.4 4.2 2.3 3.2 0.4 4.2 2.3 3.1 0.4 3.8 1.9 35 7 41 165 0.7 0 0.9 0.7 02/15/2007 08:30:00 3.5 0.4 4.6 2.3 3.6 0.4 4.6 2.3 3.4 0.3 4.2 2.6 35 6 40 165 0.6 0 0.9 0.4 02/15/2007 08:40:00 3.6 0.4 4.6 2.6 3.6 0.4 4.6 2.6 3.5 0.4 4.6 2.6 40 5 44 165 0.5 0 0.9 0.2 02/15/2007 08:50:00 3.5 0.4 4.6 2.6 3.6 0.4 4.6 2.6 3.4 0.4 4.6 2.3 41 4 46 165 0.7 0 0.9 0.4 02/15/2007 09:00:00 3.1 0.4 4.2 2.3 3 0.4 3.8 2.3 2.9 0.4 4.2 1.9 39 5 46 165 0.7 0 1.1 0.4 02/15/2007 09:10:00 3 0.3 3.4 2.6 2.8 0.3 3.4 2.3 2.8 0.2 3.4 2.3 32 3 43 165 0.8 0.1 0.9 0.7 02/15/2007 09:20:00 3.2 0.2 3.8 2.6 3 0.3 3.8 2.6 3 0.2 3.8 2.6 30 3 34 165 0.7 0 0.9 0.4 02/15/2007 09:30:00 3.6 0.4 4.6 2.6 3.5 0.4 4.6 2.3 3.5 0.5 4.6 2.3 27 2 27 165 1.2 0.2 1.6 0.7 02/15/2007 09:40:00 3.4 0.3 4.2 2.6 3.3 0.4 4.2 2.3 3.6 0.3 4.6 3 20 3 23 165 0.9 0.2 1.4 -0.1 02/15/2007 09:50:00 3.7 0.3 4.2 3 3.5 0.4 4.2 2.3 3.7 0.3 4.2 3 20 3 25 165 0.6 0 0.9 -0.1 02/15/2007 10:00:00 3.9 0.2 4.2 3.4 3.8 0.3 4.2 3 4 0.2 4.6 3.4 19 2 18 165 0.7 0.1 0.9 0.2 02/15/2007 10:10:00 3.7 0.3 4.2 3 3.7 0.3 4.6 3 3.8 0.3 4.6 3 22 3 23 165 0.9 0 1.1 0.7 02/15/2007 10:20:00 3.8 0.3 4.6 3 3.9 0.3 4.9 3 3.8 0.4 4.9 2.6 23 3 23 165 0.9 0 1.1 0.4 02/15/2007 10:30:00 3.3 0.3 4.2 2.6 3.3 0.3 4.2 2.3 3.2 0.3 4.2 2.3 22 3 28 165 0.9 0 1.1 0.7 02/15/2007 10:40:00 3.2 0.3 4.2 2.3 3.3 0.3 4.2 2.3 3.3 0.3 4.2 2.3 25 3 19 165 1.1 0 1.4 0.7 02/15/2007 10:50:00 3.5 0.3 4.2 3 3.5 0.3 4.2 3 3.6 0.3 4.6 2.3 23 5 19 165 1.2 0.1 1.4 0.7 02/15/2007 11:00:00 3.3 0.3 4.2 2.6 3.2 0.3 3.8 1.9 3.4 0.3 4.2 2.6 19 4 15 165 1.3 0.2 1.6 0.7 02/15/2007 11:10:00 4 0.4 4.9 2.6 3.5 0.6 4.6 1.5 3.9 0.4 4.6 2.6 16 4 12 165 1.6 0.3 2.3 0.9 02/15/2007 11:20:00 3.8 0.5 5.3 2.6 3.2 0.6 4.6 1.9 3.4 0.5 4.6 2.6 14 5 12 165 2.2 0 2.6 1.8 02/15/2007 11:30:00 4.1 0.3 4.9 3.4 3.6 0.4 4.6 2.3 4 0.4 4.9 3 14 3 18 165 2 0.1 2.3 1.8 02/15/2007 11:40:00 4.4 0.4 5.3 3.4 3.4 0.8 4.9 1.1 4.4 0.5 5.7 3 13 6 9 165 2 0.1 2.3 1.8 02/15/2007 11:50:00 4.1 0.6 4.9 2.6 2.9 0.9 4.9 0.7 4.2 0.5 5.3 2.6 10 5 22 165 1.8 0 1.8 1.4 02/15/2007 12:00:00 3.3 0.5 4.6 1.9 2.5 0.8 4.2 0.4 3.2 0.6 4.9 1.9 15 10 18 165 1.8 0.1 2.6 1.6 02/15/2007 12:10:00 5.3 0.5 6.5 3.8 5.1 0.7 6.1 2.6 5.5 0.6 6.8 3.8 22 8 10 165 1.9 0.3 2.6 1.4 02/15/2007 12:20:00 5.5 0.6 6.5 4.2 4.2 1 6.5 2.3 5.8 0.6 6.8 4.6 356 9 6 165 1.7 0.1 2.1 1.4 02/15/2007 12:30:00 4.7 0.5 6.5 3.4 4.2 0.8 6.1 2.3 4.9 0.5 6.8 3.8 349 7 7 165 1.8 0.1 2.1 1.1 02/15/2007 12:40:00 4.8 0.6 6.5 3 3.3 0.9 5.7 1.5 4.9 0.7 6.8 3.4 4 7 10 165 1.5 0 1.8 1.4 02/15/2007 12:50:00 5.6 0.7 6.8 3.8 4.8 1.1 6.8 2.3 5.8 0.7 7.2 4.2 11 7 11 165 1.6 0 1.8 1.6 02/15/2007 13:00:00 5.3 0.6 7.2 3.8 4.5 1 6.8 1.9 5.6 0.6 7.6 3.8 10 6 11 165 1.7 0 1.8 1.6 02/15/2007 13:10:00 5.9 0.5 6.8 4.2 5.5 0.8 6.8 2.3 6 0.5 7.2 4.6 14 5 21 165 1.7 0 1.8 1.6 02/15/2007 13:20:00 5.9 0.5 7.2 4.6 5 0.8 6.8 3 6.1 0.5 7.6 4.6 12 4 13 165 1.6 0 1.8 1.4 02/15/2007 13:30:00 5.5 0.4 6.8 4.6 4.8 0.8 6.8 2.6 5.8 0.4 6.8 4.6 14 5 22 165 1.5 0 1.6 1.4 02/15/2007 13:40:00 5.1 0.4 6.5 3.8 4.9 0.7 6.5 2.3 5.5 0.4 6.5 3.8 17 4 22 165 1.5 0 1.6 0.9 02/15/2007 13:50:00 5.1 0.4 6.1 3.8 4.8 0.7 6.1 2.3 5.4 0.4 6.1 4.2 17 5 20 165 1.5 0 1.6 1.4 02/15/2007 14:00:00 4.8 0.6 6.1 2.6 4.9 0.7 6.5 3 5 0.6 6.5 3.4 24 8 27 165 1.8 0.1 2.1 1.6 02/15/2007 14:10:00 5 0.8 6.5 3 4.8 1 6.5 1.9 5.3 0.8 7.2 3.4 19 9 18 165 1.9 0.1 2.3 1.4 02/15/2007 14:20:00 5.3 0.4 6.1 4.2 4.9 0.8 6.1 2.3 5.8 0.5 6.8 4.2 14 5 11 165 1.8 0 1.8 1.6 02/15/2007 14:30:00 5 0.3 6.1 4.2 3.8 0.9 5.7 1.9 5.5 0.4 6.5 4.6 10 4 15 165 1.8 0 1.8 1.6 02/15/2007 14:40:00 4.6 0.3 5.3 3.4 3.2 0.7 5.3 1.1 5 0.4 6.1 3.8 8 4 1 165 2 0 2.3 1.8 02/15/2007 14:50:00 4.4 0.4 5.3 3 2.7 0.6 4.2 1.1 4.6 0.4 5.3 3.4 5 5 10 165 2 0 2.3 1.8 02/15/2007 15:00:00 4 0.5 5.3 3 2.5 0.8 4.6 1.1 4.3 0.6 5.7 3 4 6 7 165 2.4 0.3 3.3 1.6 02/15/2007 15:10:00 3 0.7 4.2 1.1 2.4 0.6 4.2 1.1 3.2 0.6 4.6 1.9 349 7 350 165 4 0.3 4.8 3.3 02/15/2007 15:20:00 1.9 0.5 3 0.7 1.8 0.5 3 0.7 1.8 0.5 3 0.4 335 7 349 165 4.3 0.1 4.8 4 02/15/2007 15:30:00 3.4 0.9 4.6 1.1 3.2 0.9 4.6 1.1 3.4 1 4.9 1.1 16 18 347 165 3 0.7 4.3 2.1 02/15/2007 15:40:00 4.3 0.5 5.3 2.6 3.6 0.6 4.9 1.9 4.5 0.5 5.7 3 16 5 22 165 2.4 0.5 3.3 1.8 02/15/2007 15:50:00 4.2 0.7 5.7 2.6 3.2 0.8 5.3 1.5 4.3 0.7 6.1 3 354 8 5 165 2.3 0.4 3.5 1.8 02/15/2007 16:00:00 3.4 0.5 4.9 2.3 3.3 0.5 4.9 2.3 3.5 0.5 4.9 1.9 334 10 322 165 1.9 0 2.3 1.6 02/15/2007 16:10:00 2.8 0.5 4.2 1.9 2.3 0.7 3.8 0.4 3 0.4 3.8 1.9 350 12 338 165 1.8 0 2.3 1.6 02/15/2007 16:20:00 4.7 0.9 6.8 2.6 4.1 1 6.8 1.5 4.6 0.8 6.8 2.6 12 10 18 165 1.7 0.2 2.3 0.9 02/15/2007 16:30:00 5 0.5 6.1 2.6 4.3 0.9 6.1 1.9 4.9 0.6 6.1 2.6 17 8 22 165 1.4 0 1.6 1.4 02/15/2007 16:40:00 4.7 0.7 6.1 3 3.9 1 5.7 1.1 4.7 0.7 6.1 2.6 13 6 16 165 1.4 0 1.6 1.4 02/15/2007 16:50:00 4.3 0.4 5.3 3 2.9 0.9 5.3 1.1 4.5 0.5 5.7 3 8 6 17 165 1.3 0 1.6 0.9 02/15/2007 17:00:00 4.1 0.3 4.9 3.4 2.2 0.7 4.2 1.1 4.1 0.3 4.6 3 358 4 2 165 1.1 0 1.4 0.9 02/15/2007 17:10:00 4.5 0.4 5.3 3 2.4 0.6 4.9 1.1 4.5 0.4 5.3 3.4 2 5 3 165 1.1 0 1.4 0.9 02/15/2007 17:20:00 3.9 0.5 4.9 2.6 3.4 0.5 4.6 1.5 3.9 0.6 5.3 2.3 14 4 12 165 1.1 0 1.4 0.9 02/15/2007 17:30:00 4.1 0.5 5.7 3 3.2 1 5.3 1.1 3.9 0.6 5.7 2.6 10 9 15 165 1.1 0 1.4 0.9 02/15/2007 17:40:00 3.9 0.6 5.7 2.6 3.4 0.8 5.7 1.5 4.1 0.7 5.7 2.6 13 8 21 165 1.2 0 1.4 0.7 02/15/2007 17:50:00 4.3 0.6 5.7 2.6 4 0.7 5.3 1.9 4.3 0.6 5.7 3 16 7 15 165 1.2 0 1.4 0.9 02/15/2007 18:00:00 4.3 0.4 5.3 3 4.1 0.5 4.9 2.6 4.4 0.5 5.3 3.4 15 5 23 165 1.1 0 1.4 0.4 02/15/2007 18:10:00 4.4 0.5 6.1 3.4 4.1 0.7 5.3 1.9 4.3 0.6 5.7 3 14 5 9 165 1 0 1.4 0.9 02/15/2007 18:20:00 4.4 0.3 5.3 3.8 4.4 0.4 5.7 3.4 4.2 0.5 5.3 3 21 4 18 165 0.9 0 1.1 0.4 02/15/2007 18:30:00 4.2 0.3 4.9 3 4.3 0.4 4.9 3 4.2 0.4 4.9 3 22 5 22 165 0.9 0 1.1 0.7 02/15/2007 18:40:00 3.7 0.3 4.6 3 3.2 0.6 4.2 1.5 3.7 0.4 4.6 2.6 13 5 14 165 0.9 0 1.1 0.7 02/15/2007 18:50:00 3.5 0.3 4.2 2.6 3.4 0.4 4.2 1.5 3.4 0.3 4.2 2.3 23 8 12 165 0.9 0 1.1 0.9 02/15/2007 19:00:00 3.8 0.4 4.6 2.6 3.4 0.6 4.6 1.9 3.6 0.4 4.6 2.6 18 8 12 165 0.9 0 1.1 0.7 02/15/2007 19:10:00 4.2 0.5 5.7 3 3 0.7 4.9 1.5 4.1 0.5 5.3 3 8 5 360 165 0.8 0.1 1.1 0.2 02/15/2007 19:20:00 4.1 0.3 4.9 3 2.7 0.6 4.2 1.1 3.9 0.4 4.9 3 7 3 10 165 0.7 0 0.9 0.4 02/15/2007 19:30:00 3.7 0.4 4.6 2.6 2.6 0.7 4.2 0.7 3.6 0.4 4.6 2.6 10 4 15 165 0.5 0 0.7 0.2 02/15/2007 19:40:00 3.9 0.3 4.6 3 3.4 0.6 4.6 1.5 3.9 0.3 4.9 3 14 4 11 165 0.5 0 0.9 0.2 02/15/2007 19:50:00 4.3 0.3 4.9 3.4 2.8 0.6 4.2 1.5 4.4 0.3 5.3 3.8 9 4 9 165 0.5 0 0.7 0.2 02/15/2007 20:00:00 4.3 0.3 4.9 3.8 2.2 0.5 3.8 1.1 4.3 0.3 4.9 3.8 359 3 358 165 0.4 0.1 0.7 -0.1 02/15/2007 20:10:00 3.9 0.4 4.6 3 2 0.5 3.4 0.7 4 0.4 4.9 2.6 360 5 2 165 0.2 0.1 0.7 -0.3 02/15/2007 20:20:00 4 0.3 4.9 3.4 3.3 0.9 4.9 1.1 4.1 0.4 4.9 3 13 6 11 165 0.1 0.2 0.7 -0.3 02/15/2007 20:30:00 4.3 0.3 4.9 3.4 4.3 0.4 4.9 3 4.5 0.4 5.3 3.4 20 4 18 165 0.4 0 0.7 -0.1 02/15/2007 20:40:00 4.1 0.3 4.9 3.4 3 0.6 4.2 1.5 4.2 0.3 4.9 3.4 10 4 11 165 0.5 0 0.9 0.4 02/15/2007 20:50:00 4.2 0.3 5.3 3.4 2.6 0.6 4.2 1.1 4.3 0.3 4.9 3.4 7 4 11 165 0.5 0 0.7 0.2 02/15/2007 21:00:00 3.6 0.4 4.6 2.3 2.4 0.7 4.2 0.7 3.5 0.3 4.6 2.6 355 5 353 165 0.3 0.1 0.7 -0.3 02/15/2007 21:10:00 3.4 0.3 4.2 2.6 2.8 0.7 4.2 1.1 3.3 0.3 4.2 2.6 351 5 355 165 0.1 0.2 0.7 -0.3 02/15/2007 21:20:00 3.7 0.3 4.2 3 2.1 0.5 3.4 1.1 3.5 0.3 4.6 3 357 3 351 165 0.1 0.1 0.7 -0.3 02/15/2007 21:30:00 3.9 0.2 4.6 3 3 0.8 4.6 1.5 4.1 0.2 4.6 3.4 353 4 356 165 0.2 0.2 0.7 -0.3 02/15/2007 21:40:00 3.8 0.3 4.6 3.4 3 0.6 4.6 1.5 3.8 0.2 4.6 3.4 352 3 353 165 0.2 0.2 0.7 -0.3 02/15/2007 21:50:00 3.9 0.2 4.6 3 3.3 0.6 4.6 1.5 3.9 0.2 4.6 3 351 4 353 165 0.2 0.1 0.7 -0.3 02/15/2007 22:00:00 3.7 0.4 4.9 2.6 3.6 0.6 4.9 1.9 3.7 0.4 4.6 3 347 5 360 165 0.3 0.2 0.7 -0.3 02/15/2007 22:10:00 3.6 0.4 4.6 2.6 3.2 0.6 4.6 1.9 3.6 0.4 4.6 2.6 350 5 354 165 0.4 0.2 0.9 -0.3 02/15/2007 22:20:00 3.9 0.4 4.9 3 3.3 0.9 4.6 1.5 4 0.3 4.9 3 350 7 2 165 0.4 0.2 0.9 -0.1 02/15/2007 22:30:00 3.6 0.4 4.6 2.6 3.7 0.4 4.9 2.3 3.8 0.4 4.6 3 346 4 349 165 0.5 0 0.7 0.2 02/15/2007 22:40:00 3.8 0.5 4.9 2.6 3.6 0.6 4.9 2.3 3.9 0.5 5.3 3 349 4 347 165 0.5 0 0.7 0.2 02/15/2007 22:50:00 4 0.4 4.9 2.6 3.3 1 5.3 1.1 4.3 0.4 4.9 3 353 4 346 165 0.6 0 0.9 0.4 02/15/2007 23:00:00 4 0.4 4.9 3 3.1 0.9 4.9 1.5 4.2 0.4 4.9 3.4 353 4 358 165 0.7 0 0.9 0.7 02/15/2007 23:10:00 4.3 0.4 5.3 3 3.3 0.9 4.9 1.5 4.5 0.4 5.7 3.4 354 4 354 165 0.5 0 0.7 0.2 02/15/2007 23:20:00 3.1 0.4 3.8 2.3 2 0.6 3.8 0.7 3.4 0.4 4.2 2.6 2 8 359 165 0.5 0 0.9 0.2 02/15/2007 23:30:00 3.6 0.3 4.6 2.6 2.2 0.5 3.4 1.1 3.9 0.4 4.9 3 0 5 3 165 0.7 0 0.9 0.2 02/15/2007 23:40:00 3.5 0.4 4.6 2.3 2.4 0.6 3.8 1.1 3.7 0.4 4.6 2.3 357 6 2 165 0.7 0 0.9 0.2 02/15/2007 23:50:00 3.4 0.3 4.6 2.6 2.2 0.6 4.2 0.7 3.6 0.3 4.6 3 356 5 360 165 0.5 0 0.9 -0.1 02/16/2007 00:00:00 3.5 0.5 4.6 2.6 2.6 1 4.6 0.7 3.6 0.6 4.9 2.6 353 5 355 165 0.5 0 0.9 0.2 02/16/2007 00:10:00 2.8 0.3 3.4 1.9 1.9 0.7 3.4 0.7 2.8 0.3 3.4 1.9 353 4 357 165 0.5 0 0.9 0.2 02/16/2007 00:20:00 2.7 0.4 3.4 1.9 1.5 0.6 3.8 0.4 2.5 0.5 3.8 1.5 357 5 359 165 0.5 0 0.9 -0.1 02/16/2007 00:30:00 2.5 0.3 3 1.9 1.9 0.6 3 0.7 2.4 0.3 3.4 1.5 351 6 353 165 0.5 0 0.9 -0.1 02/16/2007 00:40:00 1.8 0.4 2.6 0.7 1.2 0.5 2.3 0.4 1.4 0.4 2.3 0.4 351 3 353 165 0.4 0 0.7 -0.1 02/16/2007 00:50:00 1.9 0.4 2.6 1.1 1.3 0.6 2.6 0.4 1.7 0.5 2.6 0.7 352 4 351 165 0.5 0 0.7 0.2 02/16/2007 01:00:00 2 0.3 2.6 1.1 1.6 0.6 2.6 0.4 1.7 0.4 2.6 0.7 350 4 350 165 0.4 0 0.9 -0.3 02/16/2007 01:10:00 1.6 0.2 2.3 0.7 0.8 0.4 1.9 0.4 1.5 0.3 2.3 0.7 353 3 358 165 0.3 0.1 0.7 -0.3 02/16/2007 01:20:00 2 0.4 3 1.1 1.1 0.6 2.6 0.4 2.1 0.3 3 1.5 353 3 356 165 0.4 0.1 0.7 -0.3 02/16/2007 01:30:00 2.2 0.3 3 1.5 1.7 0.6 3 0.4 2.2 0.3 3 1.5 348 5 340 165 0.3 0.1 0.7 -0.3 02/16/2007 01:40:00 2 0.4 3 1.1 1.2 0.5 2.3 0.4 2 0.4 3 1.1 357 5 356 165 0.4 0.1 0.7 -0.3 02/16/2007 01:50:00 2 0.4 2.6 1.1 1.1 0.4 2.6 0.4 2.1 0.3 3 1.5 7 6 22 165 0.4 0.1 0.7 -0.3 02/16/2007 02:00:00 2 0.3 2.6 1.1 0.9 0.3 1.9 0.4 2 0.3 2.6 1.1 4 3 358 165 0.4 0.1 0.7 -0.3 02/16/2007 02:10:00 2.6 0.3 3.4 1.9 1.2 0.5 3 0.4 2.4 0.3 3 1.5 359 5 5 165 0.4 0 0.7 -0.3 02/16/2007 02:20:00 3.3 0.4 4.2 2.3 2.7 0.8 4.2 0.7 3.3 0.4 4.2 1.9 351 6 350 165 0.3 0 0.7 0.2 02/16/2007 02:30:00 2.9 0.3 3.8 2.3 2.6 0.5 3.4 1.1 2.9 0.3 3.4 1.9 346 5 346 165 0.3 0 0.7 0.2 02/16/2007 02:40:00 2.7 0.2 3.4 2.3 2.4 0.5 3 1.1 2.6 0.3 3 1.9 347 4 347 165 0.4 0 0.7 0.2 02/16/2007 02:50:00 2.9 0.3 3.8 2.3 2.8 0.4 3.8 1.5 2.8 0.3 3.4 1.9 346 3 346 165 0.3 0 0.7 0.2 02/16/2007 03:00:00 2.8 0.3 3.4 1.9 1.9 0.6 3 0.7 2.6 0.3 3 1.9 352 4 349 165 0.4 0 0.7 0.2 02/16/2007 03:10:00 2.8 0.3 3.4 1.9 2.3 0.6 3.4 0.7 2.7 0.3 3.8 1.9 349 4 354 165 0.4 0 0.7 0.2 02/16/2007 03:20:00 2.4 0.3 3.4 1.5 1.9 0.6 3.4 0.7 2.3 0.3 3.4 1.5 349 4 342 165 0.4 0 0.7 0.2 02/16/2007 03:30:00 2.7 0.6 3.8 1.5 2.6 0.8 4.2 0.4 2.7 0.5 3.8 1.5 343 6 341 165 0.5 0 0.7 0.2 02/16/2007 03:40:00 3.2 0.4 4.2 2.3 3 0.6 4.2 0.7 3.2 0.4 4.2 2.3 342 7 359 165 0.5 0 0.7 0.2 02/16/2007 03:50:00 3.3 0.3 4.2 2.6 3 0.6 4.2 1.1 3.2 0.4 4.2 2.3 347 4 344 165 0.4 0 0.7 0.2 02/16/2007 04:00:00 3 0.3 3.8 2.3 2.8 0.5 3.8 1.1 2.9 0.4 3.8 1.9 346 4 340 165 0.3 0 0.7 0.2 02/16/2007 04:10:00 2 0.4 3 1.5 1.9 0.4 3.4 0.7 2.1 0.4 3 1.5 343 5 347 165 0.3 0 0.7 0.2 02/16/2007 04:20:00 2.2 0.4 3 1.5 2 0.5 3 0.7 2.2 0.4 3.4 1.5 343 6 355 165 0.5 0 0.7 0.2 02/16/2007 04:30:00 1.9 0.3 2.6 1.1 1.5 0.5 2.6 0.4 2 0.3 2.6 1.5 350 5 351 165 0.5 0 0.9 0.2 02/16/2007 04:40:00 2.8 0.4 3.8 1.9 2 0.6 3.4 0.7 2.9 0.5 4.2 1.9 353 6 357 165 0.6 0.1 0.9 0.2 02/16/2007 04:50:00 3.2 0.4 3.8 2.3 2.7 0.6 3.8 1.1 3.1 0.4 4.2 1.9 347 6 349 165 0.7 0.1 0.9 0.2 02/16/2007 05:00:00 2.8 0.4 3.8 1.9 2.7 0.4 3.8 1.9 2.8 0.4 3.4 1.9 340 5 348 165 0.8 0.1 0.9 0.2 02/16/2007 05:10:00 2.7 0.3 3.4 1.5 2.4 0.5 3.4 0.4 2.7 0.3 3.4 1.9 344 5 353 165 0.8 0.1 1.1 0.2 02/16/2007 05:20:00 1.3 0.7 2.3 0.4 1.1 0.7 2.3 0.4 1.5 0.6 2.6 0.4 339 9 348 165 0.8 0.1 0.9 0.4 02/16/2007 05:30:00 2.1 0.5 3 1.1 2 0.5 3 0.7 2.2 0.5 3 1.1 336 5 342 165 0.8 0.1 1.1 0.7 02/16/2007 05:40:00 2.9 0.3 3.4 2.3 2.8 0.3 3.4 1.9 2.9 0.3 3.4 2.3 343 5 340 165 0.8 0.1 1.1 0.2 02/16/2007 05:50:00 3.3 0.3 4.2 2.6 2.8 0.6 4.2 1.1 3.3 0.3 4.2 2.6 348 6 350 165 0.8 0.1 1.1 0.2 02/16/2007 06:00:00 3 0.4 3.8 1.9 2.6 0.6 3.8 0.7 3.1 0.4 3.8 1.9 348 5 343 165 0.8 0.1 0.9 0.2 02/16/2007 06:10:00 3 0.3 3.8 2.3 2.3 0.6 3.8 0.7 3.2 0.3 3.8 2.3 350 5 1 165 0.8 0.1 0.9 0.2 02/16/2007 06:20:00 3.6 0.3 4.2 2.6 3.4 0.5 4.2 1.9 3.7 0.3 4.2 3 346 4 347 165 0.8 0.1 0.9 0.2 02/16/2007 06:30:00 3.5 0.4 4.6 2.6 3.6 0.5 4.6 1.5 3.7 0.4 4.6 3 344 5 343 165 0.8 0.1 0.9 0.2 02/16/2007 06:40:00 3.6 0.3 4.6 2.6 3.7 0.5 4.6 2.3 3.8 0.3 4.6 2.6 346 4 346 165 0.8 0.1 0.9 0.4 02/16/2007 06:50:00 3.6 0.3 4.2 3 3.6 0.4 4.6 1.9 3.5 0.3 4.2 2.6 346 3 347 165 0.9 0 1.1 0.2 02/16/2007 07:00:00 3.5 0.2 4.2 3 3.2 0.5 4.2 1.9 3.5 0.3 4.2 2.6 348 3 349 165 0.9 0 1.4 0.9 02/16/2007 07:10:00 3.3 0.2 3.8 2.6 3.3 0.3 4.2 2.3 3.2 0.2 3.8 2.6 344 3 344 165 0.9 0 1.1 0.7 02/16/2007 07:20:00 3 0.2 3.4 2.3 3 0.2 3.4 2.3 3 0.3 3.8 2.6 341 3 343 165 0.9 0 1.1 0.9 02/16/2007 07:30:00 2.7 0.3 3.4 2.3 2.7 0.4 3.8 1.9 2.8 0.3 3.8 2.3 342 4 346 165 0.9 0 1.4 0.9 02/16/2007 07:40:00 2.4 0.3 3 1.5 2.4 0.3 3 1.5 2.5 0.2 3 1.9 341 3 341 165 1 0 1.4 0.9 02/16/2007 07:50:00 2.5 0.3 3 1.9 2.3 0.4 3 1.1 2.6 0.3 3 1.9 346 3 344 165 1.1 0 1.4 0.9 02/16/2007 08:00:00 2.9 0.2 3.4 2.3 1.9 0.6 3 0.7 2.9 0.3 3.4 2.3 353 4 351 165 1.1 0 1.4 0.9 02/16/2007 08:10:00 2.8 0.3 3.4 2.3 1.4 0.4 2.6 0.7 2.8 0.3 3.4 2.3 357 3 2 165 1.1 0 1.4 0.9 02/16/2007 08:20:00 2.2 0.3 2.6 1.5 1.1 0.5 2.3 0.4 2.2 0.3 3 1.5 6 7 353 165 1.1 0 1.4 0.9 02/16/2007 08:30:00 1.7 0.3 2.6 0.7 0.5 0.3 1.5 0.4 2 0.3 2.6 1.5 2 5 5 165 1.2 0 1.4 0.9 02/16/2007 08:40:00 1.4 0.4 2.6 0.4 0.5 0.3 1.5 0.4 1.6 0.4 2.6 0.7 0 4 5 165 1.3 0 1.6 1.1 02/16/2007 08:50:00 1.6 0.3 2.3 0.7 0.5 0.2 1.1 0.4 1.6 0.3 2.3 1.1 360 3 356 165 1.4 0 1.6 1.4 02/16/2007 09:00:00 1.1 0.3 1.5 0.4 0.4 0.1 1.1 0.4 1.1 0.3 1.9 0.4 4 3 3 165 1.4 0 1.6 1.4 02/16/2007 09:10:00 0.8 0.4 1.9 0.4 0.4 0.1 0.7 0.4 1 0.4 1.9 0.4 5 0 5 165 1.5 0.1 1.6 0.9 02/16/2007 09:20:00 1.3 0.5 2.6 0.4 1 0.5 2.3 0.4 1.4 0.4 2.6 0.4 18 5 19 165 1.5 0 1.6 0.9 02/16/2007 09:30:00 2.1 0.3 2.6 1.5 1.7 0.4 2.3 0.4 2.2 0.3 2.6 1.5 17 3 16 165 1.5 0 1.8 0.9 02/16/2007 09:40:00 1.6 0.3 2.3 1.1 1.3 0.3 1.9 0.4 1.7 0.2 2.3 1.1 19 3 15 165 1.5 0 1.8 0.9 02/16/2007 09:50:00 2 0.3 2.6 1.1 1.8 0.3 2.3 1.1 2 0.4 2.6 1.5 26 2 27 165 1.6 0 1.8 1.4 02/16/2007 10:00:00 2.3 0.3 3 1.9 2.1 0.3 2.6 1.5 2.4 0.3 3 1.9 25 1 25 165 1.7 0 1.8 1.4 02/16/2007 10:10:00 2.2 0.2 2.6 1.9 2.1 0.2 2.6 1.5 2.3 0.2 2.6 1.9 25 0 25 165 1.8 0 1.8 1.4 02/16/2007 10:20:00 2.7 0.2 3.4 2.3 2.5 0.2 3 1.9 2.7 0.2 3 2.3 29 2 31 165 1.8 0.1 1.8 1.4 02/16/2007 10:30:00 2.4 0.3 3 1.5 2.1 0.3 3 1.5 2.3 0.3 3 1.5 29 0 27 165 1.8 0.1 1.8 1.4 02/16/2007 10:40:00 2.2 0.3 3 1.5 2 0.3 3 1.1 2.2 0.3 3 1.5 33 3 31 165 1.8 0 1.8 1.4 02/16/2007 10:50:00 3.2 0.2 3.8 2.6 2.9 0.2 3.4 2.6 3 0.2 3.4 2.3 23 5 16 165 1.9 0 2.3 1.6 02/16/2007 11:00:00 3 0.4 4.2 1.9 2.6 0.6 3.8 1.1 2.7 0.4 3.8 1.5 17 5 17 165 2 0 2.3 1.8 02/16/2007 11:10:00 3.3 0.3 4.2 2.3 2.6 0.6 3.8 0.7 3 0.3 3.8 1.9 15 4 20 165 2.1 0 2.3 1.4 02/16/2007 11:20:00 3.3 0.5 4.2 1.9 2.8 0.7 4.2 0.7 3.1 0.5 4.6 1.9 18 6 22 165 2.1 0.2 2.6 1.6 02/16/2007 11:30:00 3.3 0.4 4.2 2.3 3.1 0.4 4.2 1.9 3.1 0.5 4.2 1.9 21 3 23 165 2.3 0.2 2.6 1.8 02/16/2007 11:40:00 3.2 0.2 3.8 2.3 2.9 0.3 3.8 1.9 3 0.3 3.8 2.3 20 3 23 165 2.5 0.1 2.8 2.1 02/16/2007 11:50:00 3.2 0.3 3.8 1.9 2.9 0.4 3.8 1.1 3.1 0.2 3.8 2.3 21 4 17 165 2.7 0 2.8 2.1 02/16/2007 12:00:00 3.3 0.3 3.8 2.3 3.1 0.3 3.8 2.3 3.2 0.4 4.2 2.3 25 3 25 165 2.6 0 2.8 2.3 02/16/2007 12:10:00 3.8 0.4 4.6 2.6 3.7 0.4 4.6 2.3 3.6 0.5 4.6 2.3 24 5 23 165 2.7 0 2.8 2.6 02/16/2007 12:20:00 3.6 0.5 4.6 2.3 3.3 0.6 4.6 1.5 3.4 0.6 4.6 1.9 18 6 31 165 2.6 0 2.8 2.3 02/16/2007 12:30:00 3.6 0.4 4.6 2.6 2.9 0.8 4.2 1.1 3.4 0.4 4.6 2.6 14 6 14 165 2.3 0 2.6 2.1 02/16/2007 12:40:00 2.8 0.4 3.8 1.9 1.8 0.8 3.8 0.4 2.8 0.4 3.8 1.9 2 10 19 165 2.2 0.1 2.6 1.8 02/16/2007 12:50:00 2.3 0.4 3 1.5 1.3 0.6 3 0.4 2.4 0.5 3.4 1.1 356 8 10 165 2.4 0 2.6 2.1 02/16/2007 13:00:00 2.3 0.3 3.4 1.5 1.3 0.5 2.6 0.4 2.2 0.3 3 1.5 355 7 349 165 2.6 0 2.8 2.6 02/16/2007 13:10:00 2.1 0.3 2.6 1.1 1.1 0.6 2.6 0.4 2 0.3 2.6 1.1 351 5 357 165 2.7 0 2.8 2.6 02/16/2007 13:20:00 1.6 0.6 2.6 0.4 1.3 0.6 2.6 0.4 1.5 0.6 2.6 0.4 331 15 355 165 2.7 0 3 2.1 02/16/2007 13:30:00 2.2 0.4 3 1.1 2 0.4 3.4 0.7 2.1 0.5 3.8 0.7 324 11 326 165 2.4 0.1 2.8 2.3 02/16/2007 13:40:00 2.8 0.4 4.6 1.1 2.6 0.4 4.2 1.1 2.8 0.4 3.8 1.9 328 7 326 165 2.3 0 2.6 1.8 02/16/2007 13:50:00 3 0.3 3.8 2.3 2.9 0.4 3.8 1.9 3 0.4 4.2 2.3 336 8 351 165 2.3 0.1 2.6 1.8 02/16/2007 14:00:00 2.5 0.4 3.4 1.5 2.3 0.4 3.4 1.1 2.4 0.4 3.8 1.5 324 9 319 165 2.2 0 2.6 1.8 02/16/2007 14:10:00 2.4 0.6 4.2 0.7 2.1 0.7 4.2 0.4 2.3 0.6 3.8 0.4 337 18 327 165 2.3 0 2.6 2.1 02/16/2007 14:20:00 2.9 0.6 4.2 1.5 2.7 0.7 3.8 0.4 2.7 0.6 4.2 1.1 334 16 3 165 2.3 0 2.6 2.1 02/16/2007 14:30:00 2.7 0.6 4.2 0.4 2.2 0.6 3.8 0.4 2.6 0.5 3.8 1.5 342 13 354 165 2.5 0 2.8 2.1 02/16/2007 14:40:00 3.1 0.4 4.2 1.9 2.3 0.8 4.2 0.4 3.1 0.3 3.8 2.3 349 6 346 165 3 0.1 3.3 2.6 02/16/2007 14:50:00 3.5 0.5 4.9 2.3 2.6 0.8 4.2 0.7 3.3 0.5 4.9 2.3 2 12 7 165 3.4 0 3.5 3.3 02/16/2007 15:00:00 4.4 0.5 5.7 3 3 0.7 4.9 1.5 4.3 0.5 5.7 3 1 8 11 165 3.2 0.1 3.5 2.6 02/16/2007 15:10:00 4.4 0.5 6.1 3.4 3.2 0.7 5.3 1.9 4.5 0.5 6.1 3.4 353 6 358 165 2.9 0 3 2.6 02/16/2007 15:20:00 4.3 0.4 5.3 3.4 3.6 0.8 4.9 1.5 4.1 0.4 4.9 3 350 6 356 165 2.7 0 2.8 2.6 02/16/2007 15:30:00 4.7 0.5 6.1 3.4 3.5 1.1 5.7 1.5 4.6 0.5 5.7 3 354 8 9 165 2.6 0.1 2.8 2.6 02/16/2007 15:40:00 4.3 0.5 5.7 3.4 2.5 0.6 4.9 1.1 4.4 0.5 5.7 3 2 6 10 165 2.4 0.1 2.6 1.8 02/16/2007 15:50:00 3.4 0.5 4.6 1.5 2.8 0.7 4.6 1.1 3.4 0.5 4.9 2.3 345 11 358 165 2.4 0.1 2.6 1.8 02/16/2007 16:00:00 3.6 0.4 4.9 2.6 3.4 0.6 4.9 1.5 3.7 0.4 4.6 2.6 342 9 346 165 2.3 0.2 2.6 1.8 02/16/2007 16:10:00 4 0.5 5.3 2.6 3.8 0.7 5.3 1.5 4 0.4 4.9 3 347 5 346 165 2.3 0.2 2.6 1.8 02/16/2007 16:20:00 4.4 0.6 5.7 3 3.6 1 5.7 0.7 4.5 0.6 6.1 3.4 352 6 354 165 2.3 0.1 2.6 1.8 02/16/2007 16:30:00 4.1 0.5 5.3 3 3.7 0.8 5.3 1.5 4.2 0.5 5.3 3 348 6 344 165 2.2 0 2.6 1.8 02/16/2007 16:40:00 3.6 0.6 5.3 2.3 2.4 1.2 5.3 0.7 3.6 0.5 5.3 2.6 356 9 339 165 2 0 2.3 1.6 02/16/2007 16:50:00 4.9 0.7 6.5 3.4 4.7 0.9 6.5 1.5 4.8 0.7 6.5 3.4 342 8 338 165 2 0 2.3 1.6 02/16/2007 17:00:00 4.6 0.4 5.7 3.8 4.4 0.6 5.7 2.3 4.6 0.4 6.5 3.4 346 6 347 165 2 0.1 2.3 1.4 02/16/2007 17:10:00 4.4 0.5 6.5 3.4 3.8 0.8 5.3 1.9 4.4 0.5 5.7 3.4 349 7 6 165 1.9 0 2.1 1.6 02/16/2007 17:20:00 4.1 0.4 5.3 3 3.5 0.9 5.3 1.1 4 0.5 5.3 3 346 10 332 165 1.9 0 2.1 1.6 02/16/2007 17:30:00 3.7 0.5 4.9 2.3 3.4 0.6 5.3 1.5 3.8 0.5 4.9 2.6 341 10 354 165 1.9 0.1 2.1 1.4 02/16/2007 17:40:00 3.7 0.8 5.7 1.9 3.6 0.9 6.1 1.5 3.8 0.8 6.1 2.6 331 10 332 165 1.9 0 2.1 1.4 02/16/2007 17:50:00 5.4 0.9 8 3.4 5.4 1 8.4 3 5.4 0.9 7.2 3.4 334 8 339 165 1.8 0.1 2.1 1.4 02/16/2007 18:00:00 6 0.9 8 3.8 5.8 1.2 8.4 2.3 5.9 0.8 7.6 4.2 343 8 347 165 1.9 0.1 2.1 1.4 02/16/2007 18:10:00 5 0.7 7.6 3.4 4.4 1.3 8 1.9 5 0.6 6.8 3.8 350 9 340 165 1.9 0.1 2.1 1.4 02/16/2007 18:20:00 5.3 1 8.4 3.4 4 1.2 7.2 1.5 5.3 1 8 3.4 1 8 7 165 1.8 0.1 1.8 1.4 02/16/2007 18:30:00 5.3 0.6 6.8 4.2 4.4 1.2 7.2 2.3 5.3 0.6 7.2 3.8 353 8 339 165 1.8 0.1 1.8 1.4 02/16/2007 18:40:00 5.7 0.6 7.6 4.6 4.5 1.2 8 2.3 5.7 0.5 7.2 4.6 357 7 344 165 1.8 0 1.8 1.4 02/16/2007 18:50:00 6.3 0.8 8 4.6 5 1 8 2.6 6.5 0.9 8.4 4.2 357 7 355 165 1.7 0 1.8 1.1 02/16/2007 19:00:00 7.1 0.8 8.8 5.3 5.7 1.1 8.8 3 7.3 0.7 9.9 5.7 355 7 359 165 1.7 0 1.8 1.1 02/16/2007 19:10:00 6.3 0.7 8 4.9 4.9 1.1 8 2.6 6.6 0.7 8.4 4.9 5 8 18 165 1.7 0 1.8 1.1 02/16/2007 19:20:00 7 1.2 9.9 4.6 5.3 1.3 9.1 2.6 7 1.1 9.5 4.6 1 7 5 165 1.7 0 1.8 1.1 02/16/2007 19:30:00 6 0.8 8.8 3.8 5.1 1.2 8 3 6.2 0.7 8.8 4.6 353 10 0 165 1.6 0 1.8 0.9 02/16/2007 19:40:00 6.5 1.1 9.1 4.2 6.2 1.3 8.8 3 6.4 1 8.8 4.6 340 11 337 165 1.7 0 1.8 1.4 02/16/2007 19:50:00 7.1 1.3 10.7 4.6 7.3 1.3 10.7 3.4 7.1 1.3 11.1 3.8 338 9 344 165 1.7 0 1.8 1.4 02/16/2007 20:00:00 8.9 1.3 13.7 5.7 9 1.3 14.1 6.1 8.9 1.2 12.2 5.3 342 7 348 165 1.7 0 1.8 0.9 02/16/2007 20:10:00 9.8 1.4 13 6.1 9.9 1.6 13 5.3 10 1.4 14.5 5.3 341 11 343 165 1.5 0 1.8 0.9 02/16/2007 20:20:00 7.3 1.6 11.5 3.8 7.2 1.3 11.1 4.2 6.9 1.9 12.2 3.4 324 23 351 165 1.6 0 1.8 1.4 02/16/2007 20:30:00 6.1 1.3 9.1 2.3 6.2 1.2 9.1 2.3 5.8 1.2 9.5 2.3 326 17 355 165 1.5 0 1.8 1.4 02/16/2007 20:40:00 5.1 2.4 10.7 0.4 5.2 2.4 10.3 0.4 4.8 2.7 10.3 0.4 325 15 342 165 1.6 0 1.8 1.4 02/16/2007 20:50:00 9.3 1.9 13.3 4.2 9.2 2 13 2.6 9 2.1 13.3 4.2 337 9 330 165 1.6 0 1.8 1.4 02/16/2007 21:00:00 9.1 1.2 13.3 6.1 8.7 1.3 12.6 4.6 9.1 1.3 13.3 6.1 343 9 330 165 1.6 0 1.8 1.4 02/16/2007 21:10:00 7.1 2.2 12.2 1.5 7.2 2.1 12.6 1.5 7 2.4 12.6 1.9 330 22 345 165 1.7 0 1.8 1.6 02/16/2007 21:20:00 7.2 2.3 12.6 2.3 7 2.1 13.7 2.3 6.8 2.4 13 1.1 337 19 339 165 1.7 0.1 1.8 1.6 02/16/2007 21:30:00 8.3 1.8 11.5 3 8.2 1.8 11.5 3.4 7.9 1.8 11.8 4.2 331 14 346 165 1.8 0 1.8 1.6 02/16/2007 21:40:00 9.1 2.4 14.1 4.2 9 2.4 14.1 4.2 8.6 2.3 14.1 4.2 335 13 336 165 1.8 0 1.8 1.6 02/16/2007 21:50:00 10.1 1.4 13.7 6.5 9.9 1.4 13.7 6.1 9.5 1.5 13.3 5.7 335 8 336 165 1.8 0 1.8 1.6 02/16/2007 22:00:00 11.5 1.5 14.5 7.6 11.3 1.5 14.5 7.2 10.7 1.7 14.5 6.5 336 7 340 165 1.8 0 2.1 1.6 02/16/2007 22:10:00 10.8 1.5 13.7 6.1 10.6 1.5 13.7 6.1 10 1.7 14.1 5.3 337 8 340 165 1.8 0 2.1 1.6 02/16/2007 22:20:00 10.5 1.4 13.3 6.8 10.3 1.5 13.3 5.7 9.6 1.5 13.3 5.3 338 8 337 165 1.8 0 1.8 1.6 02/16/2007 22:30:00 9.9 1.2 13 6.5 9.6 1.3 13 6.5 8.8 1.2 11.8 5.7 343 8 346 165 1.8 0 1.8 1.6 02/16/2007 22:40:00 10 1.7 14.5 5.7 9.8 1.8 14.9 5.7 9.1 1.8 14.1 5.7 342 9 348 165 1.7 0 1.8 1.6 02/16/2007 22:50:00 11.1 1.2 13.3 7.6 10.9 1.3 13.3 7.2 10.2 1.5 13.7 6.1 340 6 340 165 1.7 0 1.8 1.1 02/16/2007 23:00:00 11.2 1.1 13.7 8.4 11 1.2 14.1 8 10.6 1.2 13.3 6.8 338 7 343 165 1.5 0 1.8 0.9 02/16/2007 23:10:00 10.5 1.3 13.3 6.8 10.4 1.4 13.3 6.5 10 1.3 13.3 6.1 340 7 339 165 1.6 0 1.8 1.1 02/16/2007 23:20:00 11.2 1 13.7 8.4 11.2 1.1 14.1 8 11 1 14.1 7.6 341 6 344 165 1.7 0.1 1.8 1.1 02/16/2007 23:30:00 11.5 1 13.7 8.8 11.5 1 14.1 8.8 10.9 1.1 13.7 8 340 5 342 165 1.7 0 1.8 1.4 02/16/2007 23:40:00 10.4 1.3 14.1 6.5 10.3 1.7 14.5 6.1 10.2 1.4 13.3 6.8 344 7 344 165 1.5 0 1.8 0.9 02/16/2007 23:50:00 9.6 1.1 12.6 6.5 9.6 1.1 13 6.5 9.5 1 12.6 6.5 340 6 340 165 1.7 0.1 1.8 1.4 02/17/2007 00:00:00 9.4 1.2 12.2 6.1 9.4 1.2 11.8 6.1 9.4 1.2 12.6 6.1 342 6 357 165 1.8 0.1 2.1 1.4 02/17/2007 00:10:00 9.2 0.9 11.8 7.2 9.3 1 11.8 6.8 9.1 1 11.5 6.8 341 5 349 165 1.7 0 1.8 1.4 02/17/2007 00:20:00 8.4 0.9 11.1 5.3 8.3 1.1 10.7 5.3 8.2 1 11.1 6.1 343 7 347 165 1.4 0.1 1.8 0.9 02/17/2007 00:30:00 7 0.9 9.5 4.2 6.9 1 9.5 3.8 6.5 0.8 9.1 4.2 338 10 351 165 1.5 0 1.8 0.9 02/17/2007 00:40:00 8 0.8 9.9 5.7 8 0.7 9.9 5.7 7.9 0.7 9.5 5.7 337 8 332 165 1.5 0 1.8 1.1 02/17/2007 00:50:00 7.3 1.3 11.1 3.8 7.3 1.3 9.9 4.2 7.2 1.2 9.9 4.2 333 8 328 165 1.4 0.1 1.6 1.1 02/17/2007 01:00:00 8.2 1 11.5 5.3 8.2 1 11.5 5.7 8.3 1 11.5 5.7 336 8 344 165 1.4 0.1 1.6 1.1 02/17/2007 01:10:00 7.1 1 9.5 4.9 7 1 9.5 3.4 7.1 0.9 9.1 4.9 334 9 333 165 1.4 0 1.6 1.1 02/17/2007 01:20:00 7.7 1.1 10.3 4.9 7.5 1.1 10.7 4.2 7.6 1 10.3 5.3 340 9 360 165 1.4 0 1.6 1.1 02/17/2007 01:30:00 6.8 0.9 9.5 4.2 6.7 1.1 9.1 3.4 6.7 0.8 8.4 4.6 336 12 327 165 1.5 0 1.6 1.4 02/17/2007 01:40:00 7.9 1.2 11.8 4.9 7.6 1.5 11.5 3.4 7.9 1.3 11.8 4.2 342 10 344 165 1.4 0.1 1.6 1.1 02/17/2007 01:50:00 7.8 1 9.9 4.6 7.8 1 10.7 4.6 8.1 1 10.7 5.3 344 6 347 165 1.3 0.1 1.6 0.9 02/17/2007 02:00:00 8.1 1 10.7 5.7 7.3 1.6 10.3 3 8.4 1 10.7 5.7 348 9 354 165 1.1 0.2 1.8 0.4 02/17/2007 02:10:00 6.7 0.7 8.8 4.9 6.3 1 8.4 3.4 6.9 0.9 8.8 4.6 339 18 353 165 1.1 0.2 1.4 0.4 02/17/2007 02:20:00 6 0.8 8 3.4 6.1 0.7 8 3.4 6 0.6 7.6 4.2 317 10 321 165 0.9 0.1 1.1 0.7 02/17/2007 02:30:00 5.9 0.8 8.4 3.8 5.8 0.8 8 3.8 6 0.9 8.8 3.8 330 15 313 165 0.7 0.1 0.9 0.2 02/17/2007 02:40:00 5.6 0.9 8 3.8 5.2 0.8 8 3 5.7 1 8.4 3.4 338 17 348 165 0.9 0 1.1 0.7 02/17/2007 02:50:00 6 1 8.4 3 6 1 9.1 3 5.4 1 8 2.6 300 17 282 165 0.8 0.1 1.1 0.2 02/17/2007 03:00:00 5.7 0.9 8.4 3 5.7 0.9 8.4 3 5.2 1 7.2 3 310 16 310 165 0.8 0.1 1.4 0.4 02/17/2007 03:10:00 6.2 0.9 8.8 4.2 6.2 0.8 8.4 4.2 5.1 0.9 8.4 2.3 302 9 302 165 0.8 0.1 1.1 0.4 02/17/2007 03:20:00 5.6 1 8 3 5.7 1 8.4 3.4 5.1 0.9 9.1 3.4 312 15 290 165 0.8 0.1 1.1 0.7 02/17/2007 03:30:00 5.8 0.8 7.6 3.4 5.9 0.8 7.6 3.4 5.2 0.9 8 3 305 13 301 165 0.9 0.1 1.4 0.7 02/17/2007 03:40:00 6 0.9 8 3.4 6.1 0.8 8 3.8 5 0.7 7.6 3 300 9 299 165 0.8 0 0.9 0.4 02/17/2007 03:50:00 5.5 0.9 7.6 3.4 5.6 0.8 7.6 3.4 4.9 0.8 7.2 2.6 305 10 299 165 0.8 0 0.9 0.4 02/17/2007 04:00:00 6.3 0.8 8 4.2 6.2 0.8 8.4 3.8 5.6 0.8 8.4 3.4 308 11 305 165 0.7 0 0.9 0.2 02/17/2007 04:10:00 7.5 1 9.5 4.9 7.4 1 9.5 4.9 6.1 0.8 8.8 3.8 302 8 307 165 0.7 0 0.9 0.2 02/17/2007 04:20:00 7 1 9.9 4.9 6.9 1 9.9 4.9 6 0.9 8.8 3.8 303 9 294 165 0.7 0 0.9 0.2 02/17/2007 04:30:00 7.4 0.9 9.5 5.3 7.4 0.9 9.5 4.9 5.9 1 10.3 3.8 297 8 290 165 0.7 0 0.9 0.4 02/17/2007 04:40:00 6.5 1 8.8 3.4 6.5 1.1 8.8 3 6.2 1.2 10.7 2.3 293 13 292 165 0.7 0 0.9 0.2 02/17/2007 04:50:00 6.8 0.8 9.1 4.9 6.9 0.9 9.1 4.9 6.9 1.2 9.1 3.8 284 8 284 165 0.7 0 0.9 0.2 02/17/2007 05:00:00 8.1 1 9.9 5.7 8.1 1 10.3 6.1 7.3 1.4 10.3 3.8 288 6 283 165 0.6 0 0.9 0.2 02/17/2007 05:10:00 7.9 0.7 9.5 6.1 7.9 0.7 9.5 6.1 6.7 1.2 10.3 4.2 294 8 287 165 0.6 0 0.9 0.2 02/17/2007 05:20:00 8 1 10.3 4.9 8.1 0.9 10.3 5.3 6.7 1.2 10.3 3.8 296 9 310 165 0.7 0 0.9 0.2 02/17/2007 05:30:00 8.2 0.9 9.9 5.7 8.1 0.9 9.9 6.1 6.8 1 9.5 4.9 303 9 296 165 0.7 0 0.9 0.2 02/17/2007 05:40:00 7.1 1.2 10.7 4.6 7 1.2 10.3 3.4 6.7 0.8 9.9 4.6 324 19 309 165 0.7 0.1 0.9 0.2 02/17/2007 05:50:00 7.4 0.7 9.1 4.9 7.4 0.7 9.1 4.9 6.9 0.9 9.1 4.6 318 15 341 165 0.7 0.1 1.4 0.2 02/17/2007 06:00:00 6.6 0.6 8 5.3 6.5 0.8 8.4 3.4 6.8 0.6 8.4 5.7 341 9 343 165 0.8 0.2 1.4 0.2 02/17/2007 06:10:00 7 0.7 8.8 5.7 7.1 0.9 9.1 3.4 7.2 0.7 9.1 5.7 343 6 348 165 1.1 0.1 1.4 0.7 02/17/2007 06:20:00 5.5 0.5 7.2 3.8 5.5 0.5 7.2 3.8 5.3 0.6 6.5 3.4 320 12 308 165 0.8 0.2 1.4 0.2 02/17/2007 06:30:00 6.5 0.8 8.8 4.2 6.5 0.8 8.4 3.4 5.2 0.9 7.6 3.4 298 9 302 165 0.7 0.2 0.9 0.2 02/17/2007 06:40:00 6 0.8 8 4.2 5.9 0.8 7.6 4.2 4.9 0.7 6.8 3 307 6 297 165 0.7 0.2 0.9 -0.1 02/17/2007 06:50:00 3.8 0.7 5.3 1.9 3.7 0.8 5.3 1.9 3.1 0.8 4.9 1.1 304 8 305 165 0.5 0 0.7 -0.1 02/17/2007 07:00:00 2.4 0.8 4.2 0.4 2.3 0.8 4.6 0.4 1.8 0.7 3.8 0.4 299 11 293 165 0.7 0.1 1.1 0.2 02/17/2007 07:10:00 2 0.6 3.8 0.4 2.1 0.6 3.4 0.4 1.7 0.6 3 0.4 315 15 297 165 0.8 0 0.9 0.7 02/17/2007 07:20:00 1.5 0.6 2.6 0.4 1.2 0.5 2.3 0.4 1.5 0.5 2.6 0.4 352 15 2 165 0.8 0.1 1.1 0.2 02/17/2007 07:30:00 2.3 0.5 3 1.1 1.2 0.4 2.3 0.4 2.4 0.4 3 1.5 0 7 4 165 0.5 0 0.9 -0.1 02/17/2007 07:40:00 1 0.4 1.9 0.4 0.6 0.4 1.9 0.4 1.2 0.5 2.3 0.4 354 7 346 165 0.3 0.1 0.7 -0.3 02/17/2007 07:50:00 0.4 0 0.7 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 353 0 353 165 0.1 0 0.4 -0.5 02/17/2007 08:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 329 45 165 165 -0.2 0 -0.1 -0.5 02/17/2007 08:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 246 0 165 165 0.2 0.2 0.7 -0.3 02/17/2007 08:20:00 0.4 0 0.4 0.4 0.4 0 0.7 0.4 0.4 0.1 1.1 0.4 273 13 165 165 0.5 0 0.7 0.2 02/17/2007 08:30:00 1.2 0.4 1.9 0.4 1.3 0.4 1.9 0.4 1 0.5 1.9 0.4 294 13 296 165 0.3 0.1 0.7 -0.1 02/17/2007 08:40:00 1.3 0.4 2.3 0.4 1.2 0.5 2.3 0.4 1.5 0.3 2.3 0.7 336 11 351 165 0.1 0.1 0.7 -0.3 02/17/2007 08:50:00 1.1 0.6 2.3 0.4 0.7 0.4 2.3 0.4 1.6 0.6 2.6 0.4 3 6 5 165 0.7 0.1 0.9 0.2 02/17/2007 09:00:00 0.4 0.2 1.5 0.4 0.4 0.1 1.5 0.4 0.5 0.3 1.1 0.4 304 69 192 165 1.2 0.2 1.6 0.2 02/17/2007 09:10:00 0.4 0.2 1.5 0.4 0.4 0.2 1.5 0.4 0.4 0.1 1.1 0.4 187 8 209 165 1.8 0.3 2.6 0.9 02/17/2007 09:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 182 1 165 165 2.8 0.3 3.3 1.8 02/17/2007 09:30:00 0.4 0.1 1.1 0.4 0.4 0 0.4 0.4 0.4 0.1 1.1 0.4 182 4 167 165 3 0.1 3.5 2.8 02/17/2007 09:40:00 0.8 0.4 1.9 0.4 0.5 0.3 1.9 0.4 0.5 0.3 1.9 0.4 154 35 160 165 2.8 0 3.3 2.6 02/17/2007 09:50:00 1.4 0.4 2.3 0.4 1.1 0.5 2.3 0.4 1.4 0.5 2.3 0.4 166 7 161 165 3 0.2 3.5 2.8 02/17/2007 10:00:00 1.9 0.7 3.4 0.4 1.7 0.8 3 0.4 1.8 0.7 3.4 0.4 162 10 180 165 2.9 0 3 2.6 02/17/2007 10:10:00 2.2 0.6 3.8 0.4 2.1 0.7 3.8 0.4 2.4 0.6 3.8 1.1 171 10 179 165 2.7 0 3.3 2.6 02/17/2007 10:20:00 1.9 0.9 4.2 0.4 1.8 1 4.2 0.4 2.3 0.8 4.2 0.7 168 9 182 165 2.7 0.1 3.5 2.3 02/17/2007 10:30:00 1.8 1 3.4 0.4 1.7 0.9 3.4 0.4 2.2 0.8 3.8 0.4 171 7 179 165 2.8 0.1 3.3 2.3 02/17/2007 10:40:00 2.6 0.4 3.4 1.5 2.5 0.5 3.8 1.1 2.8 0.4 3.8 1.5 168 7 164 165 2.4 0 2.8 2.3 02/17/2007 10:50:00 2.5 0.3 3.4 1.5 2.3 0.4 3.8 1.5 2.8 0.4 3.8 1.5 165 6 180 165 2.4 0 2.8 2.3 02/17/2007 11:00:00 3.4 0.6 4.6 1.9 3.2 0.6 4.6 1.9 3.6 0.5 4.9 1.9 156 9 145 165 2.3 0 2.8 2.1 02/17/2007 11:10:00 3.6 0.6 4.9 2.3 3.4 0.5 4.9 1.9 3.8 0.6 5.3 2.6 152 8 168 165 2.2 0 2.8 1.8 02/17/2007 11:20:00 4.2 0.4 5.7 2.6 4 0.5 5.7 2.6 4.3 0.5 5.3 3 157 5 162 165 2 0 2.3 1.8 02/17/2007 11:30:00 4.7 0.4 6.5 3.8 4.5 0.4 6.1 3.8 4.8 0.4 6.5 3.8 161 6 175 165 2.1 0 2.6 1.8 02/17/2007 11:40:00 5.3 0.4 6.5 4.2 5.1 0.4 6.1 4.2 5.5 0.4 6.8 4.6 164 6 156 165 2 0 2.3 1.8 02/17/2007 11:50:00 5.3 0.5 6.5 4.2 5.1 0.5 6.1 3.8 5.5 0.6 6.8 4.2 166 7 170 165 2.1 0 2.3 1.8 02/17/2007 12:00:00 5.5 0.5 6.8 4.2 5.3 0.5 6.5 3.8 5.7 0.5 7.2 4.6 162 5 162 165 1.8 0.3 2.6 1.4 02/17/2007 12:10:00 6.2 0.6 8 4.6 5.9 0.6 7.6 4.6 6.4 0.6 7.6 4.9 165 11 163 165 2.2 0.1 2.6 1.8 02/17/2007 12:20:00 6 0.4 6.8 4.9 5.7 0.4 6.8 4.9 6 0.5 7.6 4.6 161 5 163 165 2 0 2.3 1.8 02/17/2007 12:30:00 3.8 0.7 5.3 2.3 3.7 0.7 5.3 1.9 4 0.7 5.7 2.6 161 9 154 165 2.4 0.1 2.8 2.1 02/17/2007 12:40:00 2.1 0.7 4.2 0.7 2.1 0.8 4.2 0.4 2.3 0.8 4.2 0.4 215 32 242 165 1.7 0.1 2.3 1.4 02/17/2007 12:50:00 2.8 0.9 4.9 0.7 2.7 0.9 4.9 0.4 3 0.8 4.6 0.4 190 15 197 165 1.8 0.1 2.3 1.4 02/17/2007 13:00:00 3.6 0.7 5.7 1.5 3.5 0.7 5.7 1.5 3.6 0.7 5.3 1.5 190 15 204 165 2 0.1 2.3 1.8 02/17/2007 13:10:00 2.7 0.5 3.8 1.5 2.6 0.5 3.8 1.1 2.9 0.5 4.2 1.5 191 13 198 165 1.8 0 2.1 1.6 02/17/2007 13:20:00 1.8 0.6 3 0.4 1.9 0.6 3.4 0.4 2.3 0.6 4.2 0.7 168 11 165 165 1.6 0 1.8 1.4 02/17/2007 13:30:00 3 0.6 4.6 1.5 2.9 0.5 4.2 1.5 3.3 0.6 4.6 1.9 179 4 178 165 1.4 0.1 1.8 1.4 02/17/2007 13:40:00 4.4 0.6 5.7 3 4.2 0.5 5.7 3 4.6 0.5 6.1 3.4 172 6 168 165 1.2 0 1.6 0.9 02/17/2007 13:50:00 4.7 0.4 5.7 3.4 4.5 0.4 5.3 3.4 4.9 0.4 6.1 3.4 171 6 177 165 1.2 0.1 1.8 0.9 02/17/2007 14:00:00 4 0.3 4.9 3 3.8 0.3 4.6 3 4.1 0.4 4.9 3 163 6 161 165 1.4 0 1.8 1.4 02/17/2007 14:10:00 4.3 0.5 6.1 3 4.2 0.5 5.7 3 4.5 0.5 5.7 3.4 162 5 171 165 1.6 0.2 2.6 1.4 02/17/2007 14:20:00 5.5 0.4 6.8 4.2 5.2 0.4 6.5 3.8 5.7 0.4 6.8 4.6 172 6 183 165 1.9 0 2.3 1.6 02/17/2007 14:30:00 6.1 0.9 8 3.8 5.8 0.9 7.6 3.8 6.3 1 8 3.8 176 7 185 165 1.8 0.1 2.6 1.6 02/17/2007 14:40:00 7.6 0.5 8.4 6.1 7.2 0.4 8 6.1 7.7 0.4 8.4 6.5 166 15 170 165 1.6 0 2.3 1.6 02/17/2007 14:50:00 7.4 0.5 8.8 6.1 7 0.5 8.8 5.7 7.6 0.6 9.1 6.1 167 8 165 165 1.6 0 2.1 1.4 02/17/2007 15:00:00 8.1 0.4 9.1 6.5 7.7 0.4 8.8 6.5 8.3 0.5 9.5 6.5 173 4 168 165 1.6 0 1.8 1.4 02/17/2007 15:10:00 8 0.4 9.1 6.5 7.6 0.4 8.8 6.5 8.2 0.5 9.5 6.8 173 7 168 165 1.5 0 1.6 1.4 02/17/2007 15:20:00 7.7 0.4 8.8 6.5 7.3 0.3 8.4 6.5 7.8 0.4 8.8 6.5 168 5 168 165 1.4 0 1.6 1.4 02/17/2007 15:30:00 7.9 0.4 8.8 6.5 7.5 0.4 8.8 6.1 8.1 0.5 9.1 6.8 169 5 165 165 1.3 0 1.6 0.9 02/17/2007 15:40:00 6.5 0.8 8 4.6 6.3 0.6 7.6 4.6 6.8 0.7 8.4 4.9 174 7 165 165 1.1 0 1.4 0.9 02/17/2007 15:50:00 5.3 0.5 6.5 3.8 5.3 0.4 6.5 3.8 5.7 0.4 6.8 4.6 175 6 181 165 1.1 0 1.4 0.9 02/17/2007 16:00:00 5.3 0.7 6.8 3.4 5.3 0.6 6.5 3.4 5.6 0.7 7.2 3.8 181 7 184 165 1 0 1.1 0.9 02/17/2007 16:10:00 4.7 0.6 6.1 3 4.5 0.6 5.7 3 4.8 0.6 6.1 3.4 179 7 171 165 0.9 0 1.1 0.9 02/17/2007 16:20:00 4.8 0.4 5.7 3.8 4.6 0.4 5.7 3.8 5.1 0.5 6.5 3.8 174 6 177 165 0.8 0 1.1 0.7 02/17/2007 16:30:00 4.5 0.4 5.3 3.4 4.6 0.3 5.7 3.4 4.9 0.4 5.7 3.8 172 6 178 165 0.8 0 1.4 0.7 02/17/2007 16:40:00 4.3 0.4 5.3 3.4 4.4 0.3 5.3 3.4 4.7 0.4 5.7 3.4 170 6 173 165 0.8 0 0.9 0.7 02/17/2007 16:50:00 3.7 0.4 4.6 3 3.6 0.5 4.6 2.6 3.9 0.5 4.9 3 169 7 171 165 0.8 0 0.9 0.7 02/17/2007 17:00:00 3.3 0.3 4.2 2.6 3.1 0.3 4.2 2.6 3.3 0.3 4.2 2.6 164 6 164 165 0.8 0 0.9 0.7 02/17/2007 17:10:00 2.7 0.3 3.4 2.3 2.5 0.3 3 1.9 2.7 0.3 3.4 2.3 164 8 166 165 0.8 0 0.9 0.7 02/17/2007 17:20:00 3 0.3 3.8 2.3 2.9 0.2 3.4 2.3 3.1 0.3 3.8 2.6 159 2 159 165 0.7 0 0.9 0.7 02/17/2007 17:30:00 3.5 0.4 4.2 2.6 3.5 0.4 4.2 2.6 3.6 0.4 4.6 2.6 154 5 160 165 0.7 0 0.9 0.7 02/17/2007 17:40:00 4.4 0.5 5.7 3.4 4.3 0.5 5.7 3.4 4.6 0.5 5.7 3.4 157 5 160 165 0.7 0 0.9 0.7 02/17/2007 17:50:00 5.9 0.4 6.8 4.6 5.7 0.4 6.8 4.6 5.9 0.5 7.6 4.6 158 3 158 165 0.7 0 0.9 0.7 02/17/2007 18:00:00 6.4 0.6 7.6 4.9 6.2 0.5 7.6 4.9 6.4 0.6 8 4.6 160 5 174 165 0.7 0 0.9 0.7 02/17/2007 18:10:00 6.5 0.4 7.6 5.3 6.5 0.4 7.6 5.7 6.8 0.5 8 5.3 155 5 144 165 0.7 0 0.9 0.4 02/17/2007 18:20:00 6.9 0.5 8 5.3 6.8 0.5 8 5.3 7.1 0.5 8 5.7 158 7 164 165 0.7 0 0.9 0.7 02/17/2007 18:30:00 7.5 0.6 9.5 6.1 7.4 0.6 9.5 6.1 7.5 0.6 9.1 6.1 160 8 163 165 0.6 0 1.1 0.4 02/17/2007 18:40:00 8.1 0.9 10.3 6.1 7.8 0.8 9.9 6.1 8.1 0.9 10.3 6.1 159 9 160 165 0.5 0 1.1 0.4 02/17/2007 18:50:00 8.4 0.7 10.3 6.1 8.2 0.6 9.9 6.1 8.5 0.7 10.3 6.5 155 5 154 165 0.6 0 0.7 0.4 02/17/2007 19:00:00 8.4 0.5 9.5 6.8 8.2 0.5 9.1 6.8 8.6 0.5 9.9 7.2 157 7 153 165 0.6 0 0.9 0.4 02/17/2007 19:10:00 7.6 0.6 9.1 5.7 7.5 0.6 8.8 5.7 7.9 0.7 9.5 5.7 158 6 158 165 0.7 0 0.9 0.4 02/17/2007 19:20:00 8 0.4 8.8 6.5 7.8 0.4 8.8 6.8 8.2 0.4 9.1 6.8 163 15 162 165 0.6 0 0.9 0.4 02/17/2007 19:30:00 7.7 0.5 8.8 6.5 7.5 0.5 8.4 6.1 7.9 0.5 8.8 6.1 165 10 165 165 0.6 0 0.9 0.4 02/17/2007 19:40:00 6.6 0.6 8 4.9 6.4 0.6 7.6 4.9 6.6 0.7 8 4.9 166 7 165 165 0.6 0 0.9 0.2 02/17/2007 19:50:00 5.3 0.7 6.5 3.8 5.1 0.6 6.1 3.4 5.5 0.7 6.5 3.8 166 12 165 165 0.6 0 0.9 0.4 02/17/2007 20:00:00 4.4 0.3 4.9 3.8 4.2 0.3 4.9 3.4 4.5 0.3 5.3 3.8 160 2 162 165 0.7 0 0.9 0.4 02/17/2007 20:10:00 4.6 0.4 5.7 3.8 4.4 0.3 5.3 3.8 4.8 0.3 5.7 3.8 161 1 162 165 0.6 0 0.9 0.4 02/17/2007 20:20:00 3.6 0.5 5.3 2.3 3.5 0.5 4.9 2.3 3.7 0.6 5.3 2.6 161 1 162 165 0.6 0 0.9 0.4 02/17/2007 20:30:00 3.6 0.4 4.6 2.6 3.4 0.4 4.2 2.6 3.6 0.4 4.9 2.6 161 1 162 165 0.5 0 0.7 0.2 02/17/2007 20:40:00 3.3 0.4 4.2 2.3 3.1 0.3 3.8 2.3 3.2 0.4 4.2 2.3 161 1 162 165 0.5 0 0.7 -0.1 02/17/2007 20:50:00 3.8 0.3 4.6 3 3.7 0.3 4.2 3 3.8 0.3 4.6 3 161 1 162 165 0.6 0 0.9 0.2 02/17/2007 21:00:00 3.9 0.2 4.6 3.4 3.7 0.2 4.2 3.4 3.9 0.2 4.6 3.4 161 1 162 165 0.6 0 0.9 -0.1 02/17/2007 21:10:00 3.7 0.3 4.2 3 3.6 0.3 4.2 2.6 3.7 0.3 4.6 3 161 1 162 165 0.7 0 0.9 0.7 02/17/2007 21:20:00 3.1 0.4 3.8 1.9 3 0.3 3.4 2.3 3 0.3 3.4 1.9 161 1 160 165 0.7 0 0.9 0.7 02/17/2007 21:30:00 2.6 0.3 3.4 1.9 2.6 0.3 3.4 1.9 2.6 0.3 3.4 1.9 161 1 161 165 0.7 0 0.9 0.7 02/17/2007 21:40:00 2.8 0.3 3.4 1.9 2.8 0.3 3.4 1.9 2.7 0.4 3.8 1.5 160 1 162 165 0.8 0 0.9 0.7 02/17/2007 21:50:00 2.1 0.3 2.6 1.1 2.2 0.4 3 1.1 2.1 0.4 3 1.1 160 1 160 165 0.8 0 0.9 0.7 02/17/2007 22:00:00 2.3 0.3 3.4 1.5 2.4 0.3 3 1.5 2.1 0.4 3 1.1 160 2 162 165 0.8 0 0.9 0.2 02/17/2007 22:10:00 2.2 0.8 4.2 0.4 2.2 0.7 4.2 0.4 1.2 1 3.4 0.4 160 2 162 165 0.7 0 0.9 0.7 02/17/2007 22:20:00 0.8 0.7 3 0.4 1.6 0.7 3 0.4 0.4 0 0.4 0.4 160 1 158 165 0.7 0 0.9 0.7 02/17/2007 22:30:00 0.4 0 0.4 0.4 1.7 0.6 3 0.4 0.4 0 0.4 0.4 161 1 165 165 0.6 0 0.9 0.2 02/17/2007 22:40:00 0.4 0 0.4 0.4 2.2 0.5 3.4 0.4 0.4 0 0.4 0.4 161 1 165 165 0.5 0 0.7 0.2 02/17/2007 22:50:00 0.4 0 0.4 0.4 1.6 0.6 2.6 0.4 0.4 0 0.4 0.4 161 1 165 165 0.4 0 0.7 -0.1 02/17/2007 23:00:00 0.4 0 0.4 0.4 1.8 0.3 2.6 1.1 0.4 0 0.4 0.4 161 1 165 165 0.4 0 0.7 -0.1 02/17/2007 23:10:00 0.4 0 0.4 0.4 1.6 0.5 2.3 0.4 0.4 0 0.4 0.4 161 2 165 165 0.4 0.1 0.7 -0.3 02/17/2007 23:20:00 0.4 0 0.4 0.4 0.4 0.2 1.1 0.4 0.4 0 0.4 0.4 161 1 165 165 0.4 0.1 0.7 -0.1 02/17/2007 23:30:00 0.4 0 0.4 0.4 0.8 0.5 1.9 0.4 0.4 0 0.4 0.4 161 0 165 165 0.4 0.1 0.7 -0.3 02/17/2007 23:40:00 0.4 0 0.4 0.4 1.9 0.5 3 0.4 0.4 0 0.4 0.4 161 0 165 165 0.4 0.2 0.7 -0.3 02/17/2007 23:50:00 0.4 0 0.4 0.4 3.4 0.8 5.3 1.9 0.4 0 0.4 0.4 161 0 165 165 0.4 0.2 0.7 -0.3 02/18/2007 00:00:00 0.4 0 0.4 0.4 3.6 0.6 5.3 1.9 0.4 0 0.4 0.4 161 0 165 165 0.4 0.2 0.7 -0.3 02/18/2007 00:10:00 0.4 0 0.4 0.4 4.8 1.2 7.2 2.6 2.7 2.1 6.8 0.4 8 102 165 165 0.6 0.2 1.1 -0.1 02/18/2007 00:20:00 0.4 0 0.4 0.4 5.4 1 8 3.8 4.4 1 7.6 2.3 303 9 165 165 0.8 0.1 1.1 0.4 02/18/2007 00:30:00 0.4 0 0.4 0.4 6 1 8.8 3.8 5 1.1 7.6 2.3 307 12 165 165 0.8 0 1.1 0.7 02/18/2007 00:40:00 2.7 4.3 12.6 0.4 8.7 1.7 12.6 5.3 8.4 1.8 12.6 4.9 317 6 319 165 0.8 0 0.9 0.4 02/18/2007 00:50:00 9.3 0.9 11.5 6.8 9.3 0.9 11.5 6.5 8.9 1 11.5 6.1 314 5 316 165 0.7 0.1 0.9 0.2 02/18/2007 01:00:00 9.5 1.2 12.2 6.1 9.4 1.2 11.8 6.1 9.1 1.3 11.8 4.6 313 6 307 165 0.8 0 0.9 0.4 02/18/2007 01:10:00 9 1.2 11.5 5.7 9 1.2 11.8 6.1 8 1.3 11.1 4.6 310 8 303 165 0.8 0.1 1.1 0.2 02/18/2007 01:20:00 9.2 1.2 13.7 6.5 9.1 1.2 13 6.5 8.3 1.2 12.2 5.7 309 6 294 165 0.8 0.1 1.1 0.2 02/18/2007 01:30:00 10.3 1.6 14.5 6.8 10.2 1.7 14.5 6.8 9 1.3 13.3 5.3 309 8 308 165 1 0.2 1.6 0.9 02/18/2007 01:40:00 11.3 1.5 15.3 8.4 11.1 1.5 14.9 8 10 1.6 14.5 6.5 308 8 300 165 1.2 0 1.4 0.9 02/18/2007 01:50:00 12.4 1.3 17.2 9.5 12.2 1.3 16.8 9.5 10.9 1.4 14.9 7.2 308 7 296 165 1.2 0.1 1.6 0.9 02/18/2007 02:00:00 12.6 1.3 16.4 9.5 12.4 1.3 16.8 9.1 10.6 1.6 14.9 6.8 306 8 300 165 1.4 0.1 1.6 0.7 02/18/2007 02:10:00 13.6 1.6 17.9 9.9 13.5 1.7 17.6 9.1 11.7 1.7 15.6 7.2 307 9 320 165 1.6 0 1.8 1.1 02/18/2007 02:20:00 14.1 1.5 17.9 10.7 14 1.5 17.9 10.3 12.4 1.5 17.6 8 307 8 303 165 1.7 0 1.8 1.4 02/18/2007 02:30:00 14 1.8 18.3 9.5 13.8 1.8 18.3 9.9 11.2 1.9 17.2 6.5 300 10 277 165 1.8 0 1.8 1.4 02/18/2007 02:40:00 14.7 2.1 18.7 9.5 14.5 2.1 18.7 9.1 12.3 2.2 19.1 8 304 8 302 165 1.9 0 2.3 1.6 02/18/2007 02:50:00 15.4 2 20.6 9.9 15.3 2 21 9.9 12.9 2.3 19.1 8.4 304 8 306 165 2 0.1 2.3 1.4 02/18/2007 03:00:00 15.9 2.6 21 9.5 15.8 2.6 20.6 9.5 12.2 2.1 17.6 7.2 300 6 300 165 1.9 0.1 2.3 1.4 02/18/2007 03:10:00 15.6 2 21 9.5 15.4 2 21 10.3 12.8 1.9 19.1 8 300 9 300 165 1.9 0.1 2.3 1.4 02/18/2007 03:20:00 14.1 1.5 17.6 9.5 14 1.5 17.6 9.5 11.4 1.8 16.4 6.8 299 7 293 165 1.9 0.1 2.3 1.4 02/18/2007 03:30:00 13.1 1.7 17.2 9.1 13 1.7 17.2 8.8 10.5 1.9 16.8 6.5 295 8 298 165 1.8 0 2.1 1.4 02/18/2007 03:40:00 12.7 1.9 16.8 8.4 12.6 1.9 16.8 8.4 10.3 1.6 14.9 6.8 298 8 292 165 1.8 0 1.8 1.4 02/18/2007 03:50:00 10.7 2 15.6 4.2 10.6 2 15.3 4.6 8.6 1.7 14.1 4.9 300 9 302 165 1.7 0 1.8 1.4 02/18/2007 04:00:00 11 1.7 14.9 6.1 11 1.7 15.3 6.5 9.4 1.7 14.9 4.9 299 10 287 165 1.6 0 1.8 1.4 02/18/2007 04:10:00 10.9 2.5 17.9 4.9 10.9 2.5 17.9 5.3 9 2.6 16.4 4.6 293 9 280 165 1.7 0.1 1.8 1.4 02/18/2007 04:20:00 8.4 1.3 12.2 5.3 8.4 1.3 12.2 4.9 7 1.3 12.2 4.2 294 9 281 165 1.7 0.1 1.8 1.4 02/18/2007 04:30:00 10.5 1.7 14.1 6.5 10.5 1.7 14.5 6.8 8.5 1.4 12.2 5.3 295 8 297 165 1.8 0.1 2.1 1.4 02/18/2007 04:40:00 10.4 1.7 15.6 6.8 10.4 1.7 15.6 6.8 8.4 1.8 13 4.9 293 6 298 165 1.9 0.1 2.1 1.4 02/18/2007 04:50:00 9 1 11.5 6.5 9 1.1 11.8 6.1 6.9 1.1 10.3 4.2 295 6 290 165 1.8 0.1 2.1 1.4 02/18/2007 05:00:00 9 1.3 13 6.1 9 1.3 13.3 5.7 7 1.3 11.5 4.2 296 7 301 165 1.8 0.1 2.1 1.6 02/18/2007 05:10:00 9 1.2 13 6.8 9 1.2 13 6.5 7 1.2 11.8 4.9 297 6 296 165 1.7 0.1 1.8 1.4 02/18/2007 05:20:00 8.6 1.2 13.3 5.3 8.5 1.2 13.3 5.7 6.9 1.3 11.5 3.4 294 9 301 165 1.8 0.1 2.1 1.6 02/18/2007 05:30:00 8 1.2 11.1 4.2 8.1 1.2 11.1 5.3 6.7 1.3 10.3 4.2 290 9 297 165 1.8 0.1 2.3 1.4 02/18/2007 05:40:00 6.7 1.1 9.1 3.8 6.9 1 9.1 4.2 6.1 1.1 9.1 3.8 288 10 282 165 1.9 0.1 2.3 1.6 02/18/2007 05:50:00 6.2 0.7 8 3.4 6.5 0.7 8.4 4.6 6.1 0.7 8 4.2 278 6 282 165 1.8 0.1 2.3 1.4 02/18/2007 06:00:00 7.4 0.8 9.1 5.7 7.7 0.8 9.5 5.7 7.3 0.9 9.9 4.9 281 7 282 165 1.8 0.2 2.3 1.4 02/18/2007 06:10:00 7.9 1.4 11.5 4.6 8 1.4 11.5 4.9 7.3 1.5 11.1 3 286 6 285 165 1.8 0.2 2.3 1.4 02/18/2007 06:20:00 8.2 1.2 11.5 5.3 8.4 1.2 11.8 5.7 7.8 1.4 11.5 3.8 283 7 288 165 1.9 0.1 2.3 1.6 02/18/2007 06:30:00 7.6 1.2 10.3 4.9 7.7 1.2 10.7 4.9 7.1 1.2 10.3 3.8 284 6 286 165 1.8 0.1 2.3 1.6 02/18/2007 06:40:00 6.3 1.1 8.8 3.4 6.4 1 9.1 3.4 5.2 0.8 7.6 2.6 294 8 297 165 1.8 0.2 2.1 1.4 02/18/2007 06:50:00 4.9 0.5 6.1 3.4 4.9 0.6 6.5 3.4 4 0.7 6.1 2.3 296 8 301 165 1.7 0.1 1.8 1.4 02/18/2007 07:00:00 5.6 0.9 8.4 3.4 5.8 0.8 8.4 3.8 5.1 0.9 7.2 2.3 287 12 302 165 1.8 0 2.3 1.6 02/18/2007 07:10:00 5.4 0.8 7.2 2.6 5.6 0.7 7.2 3.8 5.4 0.8 7.2 3.8 278 9 285 165 1.8 0 1.8 1.1 02/18/2007 07:20:00 5.1 1 7.2 2.6 5.9 0.6 7.6 4.6 5.7 0.6 7.2 4.6 269 8 283 165 1.8 0.1 2.1 1.4 02/18/2007 07:30:00 6.7 0.9 8.8 3.8 6.8 0.9 9.1 4.9 6.2 0.9 8.8 3.8 284 7 288 165 1.7 0 1.8 1.4 02/18/2007 07:40:00 7.4 0.7 9.1 5.7 7.5 0.7 9.5 6.1 6.2 1.2 8.8 4.2 291 7 290 165 1.6 0 1.8 1.4 02/18/2007 07:50:00 8.4 0.7 10.7 6.5 8.4 0.7 10.7 6.5 6.6 0.8 8.8 4.6 293 5 298 165 1.7 0 1.8 1.1 02/18/2007 08:00:00 8.8 0.7 10.7 6.8 8.9 0.6 10.7 7.2 6.6 0.9 9.5 4.6 297 6 301 165 1.7 0 1.8 1.1 02/18/2007 08:10:00 7.7 0.7 9.5 5.3 7.7 0.7 9.5 5.3 5.9 0.8 8.4 3.4 300 6 291 165 1.7 0 1.8 1.1 02/18/2007 08:20:00 6.1 0.9 8.4 3.8 6.1 1 8.4 3.8 4.8 0.9 7.2 3 301 7 297 165 1.7 0 1.8 1.4 02/18/2007 08:30:00 4.1 0.6 5.7 2.6 4.1 0.6 5.3 2.6 3.3 0.6 5.7 2.3 296 8 291 165 1.5 0 1.8 1.1 02/18/2007 08:40:00 3.7 0.6 5.7 2.3 3.7 0.6 5.7 2.3 3.1 0.6 4.6 1.5 303 7 303 165 1.7 0 1.8 1.1 02/18/2007 08:50:00 4.9 0.8 6.8 3 4.9 0.8 6.8 3.4 4 0.7 5.7 2.3 304 6 303 165 1.8 0 1.8 1.6 02/18/2007 09:00:00 6.6 1.1 9.1 3.8 6.6 1.1 9.1 3.8 5.1 1.1 8.4 3 297 8 296 165 1.9 0.1 2.3 1.4 02/18/2007 09:10:00 6.2 0.9 8.4 4.2 6.1 0.9 8.4 3.8 5.3 0.8 7.6 3.4 308 10 281 165 2.1 0.1 2.6 1.8 02/18/2007 09:20:00 5.2 1.2 8 2.3 5.1 1.2 8 2.3 4.4 1.1 7.2 2.3 305 10 301 165 2.4 0.1 2.6 1.8 02/18/2007 09:30:00 3.1 1 5.3 0.7 3.1 1 5.3 0.4 2.5 1 4.9 0.4 293 15 285 165 2.7 0.2 3 2.3 02/18/2007 09:40:00 4.8 0.9 6.8 3 4.7 0.9 6.8 2.6 4 0.9 6.5 2.3 305 10 304 165 2.9 0 3.3 2.6 02/18/2007 09:50:00 5.1 0.4 6.1 4.2 5.1 0.5 6.1 3.8 3.9 0.5 5.3 2.6 300 6 289 165 2.6 0 3.3 2.3 02/18/2007 10:00:00 4.4 0.6 5.7 3 4.4 0.7 5.7 2.6 3.3 0.7 4.9 0.7 303 6 306 165 3 0.2 3.5 2.6 02/18/2007 10:10:00 3.4 0.8 5.7 1.1 3.3 0.8 5.7 1.5 2.4 0.9 4.6 0.4 306 10 309 165 4.1 0.5 5.5 3 02/18/2007 10:20:00 3.4 0.8 5.3 1.1 3.3 0.8 4.9 1.1 2.8 0.9 4.9 0.4 309 11 314 165 4.3 0.2 4.8 3.8 02/18/2007 10:30:00 0.9 0.9 3.8 0.4 0.8 0.9 3.4 0.4 0.8 0.8 3.4 0.4 242 30 310 165 4.3 0.5 5 3.5 02/18/2007 10:40:00 0.4 0.2 1.1 0.4 0.4 0.1 1.1 0.4 0.4 0.1 1.1 0.4 289 66 300 165 5.6 0.4 6.7 5 02/18/2007 10:50:00 2.2 1 3.4 0.4 2.1 0.9 3.4 0.4 1.8 0.8 3.4 0.4 298 9 296 165 5 1.1 6.7 3.5 02/18/2007 11:00:00 1.4 1.1 3.4 0.4 1.4 1.1 3.4 0.4 1.4 0.9 3 0.4 301 7 288 165 3.3 0.3 4.3 2.8 02/18/2007 11:10:00 0.4 0.2 1.1 0.4 0.4 0 0.4 0.4 0.6 0.2 1.1 0.4 318 14 341 165 5.4 0.8 6.7 4.3 02/18/2007 11:20:00 0.9 0.5 1.9 0.4 0.6 0.4 1.9 0.4 0.9 0.5 1.9 0.4 286 51 321 165 5.7 0.6 6.7 4.8 02/18/2007 11:30:00 1.4 0.4 2.6 0.7 1.2 0.5 2.6 0.4 1.4 0.4 2.6 0.4 122 21 164 165 4.1 0.3 4.8 3.5 02/18/2007 11:40:00 1.2 0.5 3 0.4 1.2 0.6 2.6 0.4 1.4 0.6 2.6 0.4 134 45 177 165 3.3 0 3.5 3 02/18/2007 11:50:00 1.6 0.3 2.3 0.7 1.6 0.4 2.3 0.7 1.8 0.4 2.6 1.1 155 16 168 165 2.9 0 3.3 2.8 02/18/2007 12:00:00 2.3 0.9 3.8 0.4 2.3 0.9 3.4 0.4 2.5 0.8 3.8 0.4 144 4 145 165 2.7 0.1 3.5 2.6 02/18/2007 12:10:00 0.6 0.3 1.5 0.4 0.6 0.5 1.9 0.4 0.8 0.5 1.9 0.4 39 86 328 165 3.6 0.4 4.5 2.8 02/18/2007 12:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0.2 1.1 0.4 327 0 165 165 4.3 0.1 5 4 02/18/2007 12:30:00 1 0.5 2.3 0.4 1.2 0.5 2.3 0.4 1.6 0.4 2.3 0.7 331 11 318 165 5.9 0.9 7.3 4.3 02/18/2007 12:40:00 1.9 0.4 2.6 0.4 2 0.5 2.6 0.4 2.2 0.3 2.6 1.5 329 9 328 165 5.6 0.7 7 4.3 02/18/2007 12:50:00 1.2 0.6 2.3 0.4 0.8 0.5 1.9 0.4 1.5 0.5 2.3 0.4 343 15 319 165 4.3 0.2 4.8 3.8 02/18/2007 13:00:00 1 0.8 3 0.4 0.7 0.6 3 0.4 1.4 0.7 3.4 0.4 9 16 353 165 4.9 0.2 5.5 4.5 02/18/2007 13:10:00 2.6 0.7 4.2 1.1 2.2 1 3.8 0.4 2.6 0.8 4.2 0.4 345 13 337 165 4.7 0.3 5.5 4.3 02/18/2007 13:20:00 2.5 0.5 3.8 1.1 2.3 0.5 3.4 0.7 2.5 0.5 3.8 0.7 325 11 323 165 5.4 0.1 5.7 5 02/18/2007 13:30:00 2.4 0.5 3.4 1.1 2.2 0.5 3 0.7 2.1 0.5 3.4 0.7 309 9 302 165 5.2 0.2 6.2 4.8 02/18/2007 13:40:00 4 1 5.7 1.5 3.8 1 5.7 1.1 3.6 0.9 5.7 1.9 312 9 302 165 5.2 0.3 6 4.3 02/18/2007 13:50:00 5.5 0.5 6.5 4.2 5.6 0.5 6.5 4.2 5.4 0.5 6.5 4.2 314 3 313 165 4.1 0.3 4.8 3.5 02/18/2007 14:00:00 5.4 0.6 7.2 3.4 5.5 0.6 7.2 3.8 4.4 0.8 6.5 2.6 303 6 297 165 3.5 0.3 4.5 3 02/18/2007 14:10:00 3.6 0.8 5.3 1.9 3.7 0.9 5.3 1.9 2.8 0.6 4.2 1.5 301 6 306 165 3.2 0.2 4 2.8 02/18/2007 14:20:00 2.7 0.5 3.8 0.7 2.8 0.5 4.2 1.1 2.1 0.6 3.8 0.4 291 12 302 165 3.8 0.3 4.5 3.5 02/18/2007 14:30:00 2.1 0.6 3 0.7 2.2 0.6 3.4 1.1 1.8 0.6 3.8 0.4 289 11 296 165 3.2 0.2 3.5 2.8 02/18/2007 14:40:00 0.8 0.7 3 0.4 1 0.7 2.6 0.4 1 0.6 2.3 0.4 337 21 307 165 4.2 0.5 5.5 3.5 02/18/2007 14:50:00 1.9 0.7 3.4 0.7 2.1 0.6 3.4 1.1 2 0.7 3.4 0.4 52 12 40 165 4 0.6 5.5 2.8 02/18/2007 15:00:00 2.1 0.7 3.4 0.7 2.1 0.6 3.4 0.7 2.2 0.8 3.4 0.7 57 22 41 165 2.6 0.1 3 2.3 02/18/2007 15:10:00 0.9 0.5 1.9 0.4 0.9 0.5 1.9 0.4 0.8 0.5 1.9 0.4 56 11 74 165 2.4 0 2.8 2.3 02/18/2007 15:20:00 1 0.7 2.3 0.4 1 0.7 2.3 0.4 1 0.7 2.6 0.4 75 47 36 165 2.6 0 3 2.6 02/18/2007 15:30:00 2.2 0.4 3 1.1 2.1 0.4 3 1.1 2.3 0.3 3 1.5 20 6 9 165 2.6 0 3.3 2.6 02/18/2007 15:40:00 2.2 0.3 3.4 1.5 2.1 0.4 3 1.1 2.1 0.3 2.6 1.5 2 15 11 165 2.5 0 3 2.3 02/18/2007 15:50:00 2.6 0.6 3.4 1.1 2.5 0.8 3.8 0.7 2.8 0.5 3.8 1.5 349 6 350 165 2.6 0.1 3.3 2.6 02/18/2007 16:00:00 3.3 0.3 4.6 2.6 2.5 0.6 3.8 1.1 3.5 0.3 4.2 3 354 6 355 165 2.3 0 2.8 2.1 02/18/2007 16:10:00 4 0.6 4.9 2.6 3.7 0.9 5.3 1.5 4.2 0.6 4.9 2.6 351 4 350 165 2.1 0 2.8 1.8 02/18/2007 16:20:00 3.3 0.4 4.6 1.9 2.6 0.7 4.6 1.1 3.5 0.4 4.6 2.6 353 5 354 165 2.1 0 2.6 1.8 02/18/2007 16:30:00 2.9 0.4 4.2 1.9 1.8 0.5 3.4 0.7 3.3 0.3 4.2 2.3 2 6 357 165 2 0.1 2.3 1.8 02/18/2007 16:40:00 4.1 0.5 5.3 3 2.2 0.7 5.3 0.7 4.4 0.5 5.3 3 359 4 349 165 1.7 0.1 1.8 1.4 02/18/2007 16:50:00 5.3 0.6 6.5 3.8 3 0.5 5.3 1.9 5.6 0.6 6.8 4.2 2 4 358 165 1.4 0.1 1.8 1.4 02/18/2007 17:00:00 5.6 0.7 7.6 3.4 5 1.5 7.6 1.9 5.7 0.7 7.2 4.2 20 13 22 165 1.2 0 1.6 0.9 02/18/2007 17:10:00 5.9 0.9 7.6 3.4 6 0.9 7.6 3.4 6 0.9 7.6 3.4 33 7 36 165 0.9 0 1.4 0.7 02/18/2007 17:20:00 6.1 0.7 7.6 4.2 6.2 0.7 7.6 4.6 6 0.7 8 4.2 30 6 32 165 0.8 0 0.9 0.7 02/18/2007 17:30:00 6.5 0.8 8 4.6 6.7 0.7 8 4.9 6.5 0.8 8.4 4.6 38 6 27 165 0.8 0 1.1 0.7 02/18/2007 17:40:00 6.1 0.9 8 3.8 6.2 0.9 8 3.8 6 0.9 8 3.8 29 7 32 165 0.7 0 0.9 0.4 02/18/2007 17:50:00 5.4 0.8 7.6 3.4 5.7 0.8 7.6 4.2 5.5 0.8 7.6 3.4 37 8 43 165 0.5 0 0.9 0.2 02/18/2007 18:00:00 7 0.8 8.8 3.4 6.7 0.9 8.8 3.4 6.8 0.8 8.8 4.6 20 6 14 165 0.4 0.1 0.9 0.2 02/18/2007 18:10:00 6.4 0.7 8.4 4.6 5.5 0.9 8 3 6.4 0.6 8.4 4.6 13 5 9 165 0.2 0 0.4 -0.1 02/18/2007 18:20:00 5.6 0.5 6.8 4.6 5.1 0.7 6.5 3 5.7 0.5 6.8 4.2 16 6 15 165 0.1 0 0.2 -0.1 02/18/2007 18:30:00 6.7 0.6 8 4.6 6.4 0.7 8 3.4 6.7 0.7 8 4.9 18 4 21 165 0.1 0 0.2 -0.1 02/18/2007 18:40:00 6.8 0.6 8 4.9 6.8 0.6 8 4.9 6.7 0.6 8 4.9 24 4 15 165 -0.1 0 0.2 -0.1 02/18/2007 18:50:00 6.9 0.5 8 5.3 6.8 0.5 8 5.3 6.9 0.6 8 4.9 20 4 21 165 -0.1 0 0.2 -0.3 02/18/2007 19:00:00 7.2 0.6 8.8 5.3 7 0.7 8.4 4.2 7.2 0.6 8.4 5.7 19 4 18 165 -0.2 0 -0.1 -0.5 02/18/2007 19:10:00 7.8 0.7 9.1 6.1 6.3 1.2 8.8 3 7.8 0.7 9.1 5.3 12 4 16 165 -0.3 0 0.2 -0.5 02/18/2007 19:20:00 6.6 0.9 8.4 4.2 4.9 1.1 7.6 2.6 6.8 0.8 8.4 4.2 5 7 360 165 -0.3 0.1 0.2 -0.5 02/18/2007 19:30:00 5 1 8.4 3.4 3.6 1 7.2 1.9 5.3 1 8 3.4 3 8 358 165 -0.2 0.1 0.2 -0.3 02/18/2007 19:40:00 5.9 1.2 8.4 2.6 5.2 1.2 8.4 2.6 6 1.2 8 3 16 9 11 165 -0.3 0 -0.1 -0.5 02/18/2007 19:50:00 7 0.6 8.8 5.3 5.8 1.3 8.4 3 7 0.7 8.8 4.9 5 12 10 165 -0.5 0 -0.3 -0.8 02/18/2007 20:00:00 5 1.3 8.4 2.6 4.7 1.2 8 2.3 5.3 1.3 8 2.6 344 10 355 165 -0.5 0 -0.3 -0.8 02/18/2007 20:10:00 5.1 0.6 6.5 3 4.2 1 6.5 1.9 5.3 0.5 6.5 3.8 10 10 7 165 -0.6 0 -0.3 -0.8 02/18/2007 20:20:00 5.3 0.6 7.2 3.4 4.3 1 7.2 2.3 5.8 0.6 7.2 4.2 11 8 22 165 -0.7 0 -0.5 -1 02/18/2007 20:30:00 5.5 0.6 7.6 4.2 3.9 1 7.2 2.3 5.9 0.5 7.6 4.6 358 7 6 165 -0.8 0.1 -0.5 -0.8 02/18/2007 20:40:00 5.9 0.7 8 4.6 4.1 1 7.2 1.9 6.3 0.6 8 4.9 2 8 351 165 -0.8 0 -0.5 -1 02/18/2007 20:50:00 4.4 0.7 6.5 3 3.6 1 5.7 1.5 4.9 0.6 7.2 3.8 357 9 353 165 -0.8 0 -0.5 -1 02/18/2007 21:00:00 4.9 0.9 7.2 3 4.2 1.3 7.2 1.5 5.1 0.8 7.6 3 351 9 356 165 -0.8 0 -0.8 -1 02/18/2007 21:10:00 6.4 1.3 9.9 4.2 6.4 1.2 9.9 3.4 6.1 1 9.5 3.8 340 9 340 165 -0.8 0 -0.5 -0.8 02/18/2007 21:20:00 5.3 1.3 9.1 2.6 5.1 1.5 9.1 1.9 5.1 1.3 8.8 3 339 14 334 165 -0.6 0 -0.3 -0.8 02/18/2007 21:30:00 6.1 1.3 10.3 2.6 5.9 1.3 11.1 2.6 5.6 1.2 8.8 2.3 344 9 348 165 -0.7 0 -0.5 -0.8 02/18/2007 21:40:00 6.7 1.1 10.3 4.6 6.3 1.4 10.7 3.4 6 1.1 9.1 3 348 10 343 165 -0.8 0 -0.5 -1 02/18/2007 21:50:00 9.4 1.3 13.3 6.1 9.1 1.5 13.3 4.9 8.6 1.5 13.3 5.7 342 9 346 165 -0.9 0 -0.8 -1.2 02/18/2007 22:00:00 9.6 1.2 13.7 6.1 9.4 1.2 13 5.7 8.9 1.5 12.6 4.9 337 9 339 165 -0.9 0 -0.8 -1.2 02/18/2007 22:10:00 10.3 1.3 14.1 7.2 10.2 1.3 13.7 7.2 10.1 1.3 13.3 6.5 337 8 327 165 -0.8 0 -0.5 -1.2 02/18/2007 22:20:00 9.6 1 12.6 6.5 9.6 1.1 12.2 6.5 9.4 1 12.2 6.8 338 7 331 165 -0.8 0 -0.5 -0.8 02/18/2007 22:30:00 8.8 1.3 12.2 5.3 8.5 1.4 12.6 3.4 8.7 1.3 12.6 5.3 335 13 356 165 -0.8 0 -0.5 -0.8 02/18/2007 22:40:00 7.7 1.2 12.2 4.9 7.7 1.1 11.8 5.7 7 1.3 11.5 4.2 312 13 326 165 -0.8 0 -0.5 -0.8 02/18/2007 22:50:00 8.6 1.6 13 5.7 8.5 1.6 13 4.9 8.4 1.7 13.3 5.3 327 13 332 165 -0.9 0.1 -0.5 -1.2 02/18/2007 23:00:00 8.5 1.5 13 5.3 8.4 1.5 13.3 5.3 8.3 1.7 13 3.8 326 10 355 165 -0.9 0 -0.8 -1.2 02/18/2007 23:10:00 8.6 1.6 14.1 5.7 8.4 1.7 14.1 4.6 8.5 1.7 15.3 4.9 333 14 315 165 -0.9 0 -0.5 -1.2 02/18/2007 23:20:00 8 1.1 11.8 5.3 7.9 1.1 11.5 4.9 7.9 1 10.7 5.3 326 11 318 165 -1 0 -0.8 -1.2 02/18/2007 23:30:00 9.3 1.5 13.3 6.1 9.1 1.6 13.3 5.7 9.3 1.6 14.1 6.1 337 11 339 165 -1 0 -0.8 -1.2 02/18/2007 23:40:00 10.8 1.7 15.3 6.1 10.7 1.7 14.9 6.1 10.5 1.9 14.9 6.1 336 9 342 165 -1.1 0 -0.8 -1.4 02/18/2007 23:50:00 11.7 1.6 15.6 5.7 11.6 1.7 15.3 6.1 11.7 1.8 16.4 3.4 333 9 340 165 -1.2 0 -0.8 -1.7 02/19/2007 00:00:00 11.6 1.5 16.1 8 11.2 1.7 16.1 7.6 11.3 1.5 15.3 7.2 338 12 341 165 -1.2 0 -1 -1.4 02/19/2007 00:10:00 11.9 1.6 15.6 7.6 11.4 2.1 16.4 5.3 11.8 1.5 15.6 8 342 10 347 165 -1.2 0 -1 -1.4 02/19/2007 00:20:00 13 1.3 16.4 9.1 12.7 1.5 16.8 7.6 12.8 1.4 16.1 9.1 345 7 346 165 -1.3 0 -1 -1.7 02/19/2007 00:30:00 12.9 1.7 16.8 9.1 12.5 2.1 16.8 6.8 12.4 1.6 16.4 8.4 341 10 345 165 -1.4 0 -1.2 -1.4 02/19/2007 00:40:00 10.8 1.7 14.9 6.8 9.4 2.3 15.3 4.9 10.7 1.8 15.3 6.8 348 15 337 165 -1.4 0 -1.2 -1.9 02/19/2007 00:50:00 11.3 2.4 16.4 6.5 10.7 2.6 17.2 4.9 11.4 2.5 16.8 6.8 343 12 344 165 -1.6 0 -1.4 -2.1 02/19/2007 01:00:00 10.2 1.5 14.5 6.8 10.1 1.5 14.5 6.1 9.8 1.6 14.1 6.1 334 12 336 165 -1.7 0 -1.2 -1.9 02/19/2007 01:10:00 10.4 1.5 14.9 5.7 9.9 1.6 14.5 6.1 9.9 1.5 14.1 5.3 337 13 321 165 -1.8 0 -1.4 -2.1 02/19/2007 01:20:00 12.4 2.2 16.8 7.6 12.2 2.2 16.8 7.2 12.1 2.2 16.8 7.6 330 10 322 165 -2 0.2 -1.7 -2.4 02/19/2007 01:30:00 12.5 2.1 17.6 8 12.2 1.9 17.2 7.6 12.3 2 17.9 6.8 332 11 358 165 -1.8 0.1 -1.4 -2.4 02/19/2007 01:40:00 11.4 2 16.4 6.5 10.8 2.1 17.2 6.1 10.9 1.9 16.4 7.2 343 12 353 165 -2 0.1 -1.7 -2.6 02/19/2007 01:50:00 11.6 1.5 16.1 8 11.4 1.6 16.1 8 11.2 1.6 15.6 7.6 332 11 334 165 -2 0 -1.7 -2.1 02/19/2007 02:00:00 12.8 2 17.9 7.6 12.2 2.5 17.6 6.1 12.5 2.3 18.7 7.6 342 12 338 165 -2.1 0 -1.9 -2.4 02/19/2007 02:10:00 14.4 2 19.5 10.3 14.1 2.1 19.9 9.1 13.8 2.2 18.3 9.1 339 11 338 165 -2.2 0 -1.9 -2.8 02/19/2007 02:20:00 16.2 1.7 20.6 12.6 15.8 1.9 20.2 7.6 15.9 1.7 21 11.1 338 9 327 165 -2.1 0 -1.9 -2.6 02/19/2007 02:30:00 18.2 2 24.4 13 17.9 2.1 24 12.6 17.4 2.2 22.6 11.5 338 7 342 165 -2.2 0 -1.9 -2.6 02/19/2007 02:40:00 18 2.2 23.7 11.5 17.5 2.5 24 11.1 17.6 2.3 23.7 10.3 341 8 351 165 -2.2 0 -1.9 -2.6 02/19/2007 02:50:00 16.9 1.9 21.4 9.9 16.7 2 21.4 9.9 16.4 2 21 10.7 338 9 338 165 -2.2 0 -1.9 -3 02/19/2007 03:00:00 16.4 1.9 21 10.3 15.8 2.2 20.2 9.9 16 2 20.6 9.9 341 10 351 165 -2.1 0 -1.9 -2.8 02/19/2007 03:10:00 13.5 2 18.7 8.4 13 2 18.3 7.6 13.1 2 18.3 7.6 340 11 326 165 -2.3 0.1 -1.9 -2.8 02/19/2007 03:20:00 14.5 2.3 19.9 9.5 14.4 2.4 19.5 9.5 14.1 2.5 20.6 8.4 334 11 332 165 -2.4 0 -2.1 -2.6 02/19/2007 03:30:00 16 1.7 21.4 11.5 15.8 1.8 21.4 9.5 15.9 1.9 20.6 11.1 339 9 348 165 -2.4 0 -2.1 -2.6 02/19/2007 03:40:00 15 1.8 19.5 10.7 14.7 2 19.5 8.8 14.6 1.9 19.9 9.9 336 10 328 165 -2.3 0 -1.9 -2.6 02/19/2007 03:50:00 15.7 1.9 20.6 10.3 15.5 2 20.6 10.3 15.4 1.8 20.2 10.7 339 8 342 165 -2.3 0 -2.1 -2.6 02/19/2007 04:00:00 15.6 2 20.2 8 15.4 2 19.9 8.4 15.2 2.1 20.6 8.8 332 10 330 165 -2.4 0 -2.1 -2.6 02/19/2007 04:10:00 16.3 2.4 22.6 11.8 16 2.4 22.6 11.5 16.1 2.4 21.4 10.3 328 8 347 165 -2.3 0 -2.1 -2.6 02/19/2007 04:20:00 16.9 2.1 22.9 11.8 16.5 2.1 21.8 11.8 16.4 2.3 22.6 10.3 334 13 344 165 -2.3 0 -2.1 -2.6 02/19/2007 04:30:00 17.6 1.9 22.1 12.6 17 2 22.6 12.6 17.1 2.1 22.6 11.8 342 9 344 165 -2.1 0.1 -1.9 -2.6 02/19/2007 04:40:00 17.2 1.8 21.8 11.8 17.1 2 21.4 11.5 17.2 1.8 21.8 12.2 339 9 334 165 -1.9 0.1 -1.7 -2.4 02/19/2007 04:50:00 18.7 2.2 23.7 13.3 18.3 2.4 23.7 12.6 18.8 2.3 24 12.6 340 9 333 165 -1.8 0 -1.7 -2.4 02/19/2007 05:00:00 19.1 2.2 24.4 12.2 18.9 2.3 25.2 12.2 19.1 2.4 25.2 13.3 339 7 344 165 -1.8 0 -1.4 -1.9 02/19/2007 05:10:00 16.6 1.8 21.4 10.7 16.4 2.1 21 8.8 16.6 1.8 21 12.2 343 8 339 165 -1.8 0 -1.4 -1.9 02/19/2007 05:20:00 16.1 1.6 20.2 12.2 16 1.7 20.2 11.1 16.2 1.7 23.3 11.8 340 8 342 165 -1.6 0 -1.4 -1.9 02/19/2007 05:30:00 13.3 1.9 18.3 9.1 13 2.1 18.3 7.6 13.2 2 19.1 8 336 10 335 165 -1.7 0 -1.4 -1.9 02/19/2007 05:40:00 13.7 2.1 19.5 8.8 13.5 2.2 19.5 8.4 13 2.1 18.7 7.2 321 11 313 165 -1.7 0 -1.4 -2.1 02/19/2007 05:50:00 15.6 1.7 21 11.5 15.3 1.7 20.6 11.5 14.9 1.8 21.4 10.3 321 9 318 165 -1.7 0 -1.4 -1.9 02/19/2007 06:00:00 16.2 1.7 22.9 12.2 16 1.7 22.6 11.8 15.9 1.9 22.1 11.5 322 9 314 165 -1.8 0.1 -1.4 -2.1 02/19/2007 06:10:00 15.9 1.7 22.1 11.1 15.6 1.7 21.8 11.1 15.4 1.7 21 10.3 321 8 313 165 -1.7 0 -1.4 -2.1 02/19/2007 06:20:00 16.8 1.9 22.6 11.5 16.5 1.9 22.1 11.5 16.5 1.9 21.8 11.8 321 8 319 165 -1.7 0 -1.4 -2.1 02/19/2007 06:30:00 15.8 1.7 21 11.1 15.5 1.7 21 10.7 15.4 1.9 20.2 10.7 321 8 315 165 -1.8 0 -1.4 -2.1 02/19/2007 06:40:00 16.2 1.4 20.2 13 15.9 1.4 20.2 12.6 15.6 1.7 21.8 10.7 321 6 325 165 -1.7 0.1 -1.4 -2.1 02/19/2007 06:50:00 16.6 1.6 20.2 10.7 16.3 1.5 20.2 10.3 16.1 1.8 20.2 9.9 321 6 328 165 -1.8 0.1 -1.4 -2.1 02/19/2007 07:00:00 17.3 1.4 20.6 14.1 17 1.3 20.2 13.3 17 1.3 20.6 13.7 322 7 316 165 -1.8 0.1 -1.4 -2.1 02/19/2007 07:10:00 18 1.2 21 14.9 17.6 1.2 20.6 14.1 17.8 1.3 21.4 14.9 319 6 321 165 -1.7 0.2 -1.4 -2.1 02/19/2007 07:20:00 16.3 1.5 20.2 13.3 16 1.5 19.5 13 16.3 1.6 20.2 12.6 323 7 310 165 -1.4 0.1 -1.2 -2.1 02/19/2007 07:30:00 16 1.5 20.6 11.1 15.7 1.5 20.2 11.1 15.4 1.5 19.5 11.1 317 8 300 165 -1.4 0.1 -1.2 -1.9 02/19/2007 07:40:00 15.7 1.5 19.9 11.8 15.4 1.4 19.9 11.5 15.4 1.4 19.1 11.5 318 6 313 165 -1.4 0.1 -1.2 -1.9 02/19/2007 07:50:00 16 1.2 19.9 12.6 15.7 1.2 19.1 12.6 15.2 1.2 18.3 11.8 315 5 319 165 -1.3 0 -1 -1.9 02/19/2007 08:00:00 15.8 1.4 20.2 11.1 15.4 1.4 19.9 11.5 15.1 1.6 18.3 10.7 319 8 306 165 -1.2 0.1 -1 -1.9 02/19/2007 08:10:00 15.9 1.3 18.7 12.2 15.5 1.3 18.7 11.8 15.6 1.4 18.7 11.8 320 6 319 165 -1.2 0 -1 -1.4 02/19/2007 08:20:00 16.5 1.2 20.2 13 16.1 1.2 19.9 12.6 16.1 1.3 19.5 10.3 322 7 309 165 -1.2 0 -0.8 -1.4 02/19/2007 08:30:00 16.7 1 19.9 13.7 16.2 0.9 19.1 13.3 16.5 1.1 19.5 12.6 322 4 328 165 -1.2 0.1 -0.8 -1.4 02/19/2007 08:40:00 14.2 1.5 17.9 10.7 13.8 1.4 17.6 10.7 13.9 1.6 17.2 9.5 322 7 315 165 -1.2 0.1 -0.8 -1.4 02/19/2007 08:50:00 14.3 1.4 17.6 9.1 13.9 1.3 17.2 9.9 13.8 1.4 16.8 9.1 324 7 321 165 -1.3 0.2 -1 -1.9 02/19/2007 09:00:00 13.9 1.4 17.6 9.9 13.6 1.3 17.2 9.9 13.6 1.5 17.9 9.1 322 8 319 165 -1.2 0.2 -0.8 -1.9 02/19/2007 09:10:00 14.6 1.4 18.7 10.3 14.3 1.4 17.6 9.5 14.2 1.6 17.9 9.9 321 6 320 165 -1.1 0.2 -0.8 -1.4 02/19/2007 09:20:00 14.5 1.3 17.9 10.7 14.2 1.3 18.7 10.3 14.3 1.5 18.3 10.3 321 6 328 165 -0.9 0.3 -0.3 -1.7 02/19/2007 09:30:00 13.6 1.3 16.4 9.5 13.3 1.3 16.1 9.1 13.4 1.5 16.8 8.8 322 8 315 165 -0.4 0.1 -0.1 -0.8 02/19/2007 09:40:00 12.9 1.4 16.8 8.8 12.7 1.3 16.1 8.8 12.4 1.6 16.8 8 322 8 321 165 -0.1 0.1 0.2 -0.5 02/19/2007 09:50:00 13.1 1.3 15.6 9.5 12.8 1.2 15.6 9.5 12.6 1.4 16.4 9.1 318 6 314 165 0.1 0.1 0.4 -0.5 02/19/2007 10:00:00 12.9 1.4 15.6 8.8 12.5 1.3 14.9 8.4 12.7 1.5 15.6 9.1 317 6 316 165 0.2 0 0.7 -0.1 02/19/2007 10:10:00 12.3 1.1 14.9 9.1 12 1.1 14.5 8.8 11.7 1.2 14.9 8.4 319 8 309 165 0.4 0.1 0.9 -0.3 02/19/2007 10:20:00 12.2 1.3 15.3 8.8 11.9 1.3 15.3 8 11.8 1.3 16.4 8 320 7 315 165 0.7 0 1.1 0.7 02/19/2007 10:30:00 13.4 1.2 16.4 10.3 13 1.1 16.1 10.3 13.2 1.3 16.4 8.8 321 7 322 165 0.4 0.2 1.1 0.2 02/19/2007 10:40:00 14.5 1.6 18.7 9.9 14.2 1.6 18.7 9.9 13.9 1.7 18.3 10.3 319 9 310 165 0.2 0.1 0.7 -0.3 02/19/2007 10:50:00 15.8 1.7 20.6 10.7 15.5 1.7 19.5 11.1 15.1 1.7 20.6 10.7 316 8 317 165 0.5 0 0.7 0.2 02/19/2007 11:00:00 15 2 20.2 8.8 14.7 2 19.9 8.8 14.3 1.7 19.5 9.5 317 8 297 165 0.5 0 0.9 0.2 02/19/2007 11:10:00 15.8 1.8 19.9 10.7 15.5 1.7 20.2 10.7 15.1 1.7 19.1 10.3 316 8 302 165 0.4 0 0.9 0.2 02/19/2007 11:20:00 16.5 1.7 21 12.2 16.2 1.7 21 11.8 16 1.8 21.4 11.8 321 11 325 165 0.5 0.3 1.1 -0.1 02/19/2007 11:30:00 15.4 1.7 19.9 10.3 15.1 1.7 19.9 10.3 15 2 20.6 9.5 322 10 322 165 0.9 0 1.4 0.7 02/19/2007 11:40:00 15.8 1.5 20.6 11.5 15.6 1.5 20.6 11.1 15.1 1.6 19.1 10.7 314 7 312 165 0.9 0.1 1.4 0.4 02/19/2007 11:50:00 12.4 1.1 15.6 9.5 12.2 1.1 15.6 9.5 11.9 1.5 15.6 6.8 314 9 301 165 0.3 0.1 0.9 -0.1 02/19/2007 12:00:00 14.5 1.3 17.6 11.1 14.3 1.3 17.6 10.3 14 1.3 17.9 10.7 315 6 307 165 0 0.1 0.2 -0.8 02/19/2007 12:10:00 13.4 1.3 16.8 9.9 13.1 1.3 16.4 9.1 13 1.3 16.1 9.5 319 7 322 165 0.2 0.1 0.7 -0.1 02/19/2007 12:20:00 13.2 1.3 16.8 10.3 13 1.3 16.4 10.3 12.5 1.5 15.6 8.8 316 8 310 165 0.3 0.1 0.7 -0.3 02/19/2007 12:30:00 13.5 1.1 17.9 10.3 13.2 1.1 17.6 10.7 12.4 1.3 16.1 8.8 312 6 316 165 0.4 0 0.7 -0.1 02/19/2007 12:40:00 14.7 1.4 18.3 10.7 14.4 1.4 17.9 10.3 14 1.4 17.9 10.3 315 6 319 165 0.6 0 0.9 -0.1 02/19/2007 12:50:00 12.7 1.5 17.2 8.8 12.4 1.4 16.8 9.1 12.6 1.6 16.1 8.4 321 8 316 165 0.8 0.1 1.1 0.2 02/19/2007 13:00:00 13.2 1.3 17.2 10.3 12.9 1.3 16.8 9.9 12.5 1.4 16.4 8.8 317 6 314 165 1.1 0 1.4 0.7 02/19/2007 13:10:00 15.5 1.1 18.3 12.2 15.2 1.1 17.9 12.2 14.3 1.7 17.6 9.5 312 6 315 165 1.1 0 1.4 0.9 02/19/2007 13:20:00 15 1.2 17.9 11.1 14.6 1.2 17.6 11.1 13.8 1.5 17.2 8 312 7 319 165 0.9 0.1 1.4 0.7 02/19/2007 13:30:00 13.6 1.5 18.3 9.9 13.4 1.5 17.9 9.9 12.6 2 17.9 8.4 313 8 314 165 0.7 0.2 0.9 0.2 02/19/2007 13:40:00 14.2 1.3 17.9 10.7 13.9 1.3 17.6 10.3 13.8 1.5 17.9 8.8 316 6 312 165 0.7 0 0.9 0.2 02/19/2007 13:50:00 14.5 1.2 17.2 10.7 14.1 1.2 16.8 10.3 13.7 1.3 17.2 10.3 314 6 308 165 0.8 0.1 1.1 0.4 02/19/2007 14:00:00 11.8 1.3 15.3 8.8 11.6 1.2 14.9 8.8 11.4 1.4 15.3 6.8 321 11 310 165 1 0.1 1.4 0.7 02/19/2007 14:10:00 13.1 1.6 16.8 9.5 12.9 1.5 16.4 9.5 12.8 1.7 16.4 8.8 319 9 316 165 1.4 0.3 1.8 0.9 02/19/2007 14:20:00 14.8 1.2 17.9 10.7 14.4 1.2 17.9 10.7 13.9 1.6 18.3 9.1 313 5 319 165 1.5 0.2 1.8 0.9 02/19/2007 14:30:00 14.5 1.5 18.7 10.3 14.2 1.5 18.7 9.9 13.5 1.8 18.7 8.4 311 7 301 165 0.8 0.1 1.4 0.4 02/19/2007 14:40:00 13.3 1.3 17.2 10.3 13.1 1.3 16.8 9.9 11.5 1.7 17.2 8 308 8 317 165 0.8 0.2 1.4 0.2 02/19/2007 14:50:00 13.2 1.8 16.8 8.4 13 1.7 16.4 8.4 12 2 16.8 6.8 312 7 317 165 0.8 0 0.9 0.4 02/19/2007 15:00:00 14 1.2 17.2 9.9 13.7 1.2 16.8 9.5 12.7 1.5 16.1 9.5 312 7 319 165 1.2 0.3 1.8 0.7 02/19/2007 15:10:00 15.5 1.6 19.1 11.8 15.3 1.6 18.7 11.1 13.4 1.7 18.3 8.8 308 6 307 165 1.4 0.1 1.6 0.9 02/19/2007 15:20:00 14.5 2 19.9 10.3 14.3 2.1 19.5 9.9 12.7 1.7 18.7 8.8 308 7 298 165 1 0.1 1.4 0.7 02/19/2007 15:30:00 16.5 1.3 21 13 16.3 1.3 20.6 13 14.6 2.1 20.2 9.1 310 6 308 165 1.1 0.1 1.4 0.2 02/19/2007 15:40:00 16.9 1.7 21.4 13 16.7 1.7 21.4 12.2 15.1 1.7 19.1 10.3 310 5 313 165 1.1 0.2 1.4 0.7 02/19/2007 15:50:00 16.3 1.3 20.2 12.6 16.1 1.3 19.1 12.6 13.7 1.7 17.9 9.1 307 6 307 165 1.1 0.2 1.4 0.7 02/19/2007 16:00:00 15.9 1.5 19.1 11.5 15.7 1.5 19.1 11.5 14.1 1.5 17.9 9.5 310 7 304 165 1.1 0.2 1.6 0.7 02/19/2007 16:10:00 13.3 1.8 16.8 9.1 13.1 1.8 17.2 9.1 12.9 1.7 17.2 8.8 319 9 311 165 1.7 0.1 1.8 1.4 02/19/2007 16:20:00 13.6 2.3 17.6 7.2 13.3 2.3 17.2 7.2 13.3 2.5 17.9 7.2 320 8 310 165 1.5 0.4 2.3 0.9 02/19/2007 16:30:00 15.4 1.3 19.1 12.2 15.1 1.3 19.1 12.2 15 1.5 19.1 11.5 317 5 319 165 0.9 0.2 1.4 0.2 02/19/2007 16:40:00 15.5 1.6 18.7 11.5 15.1 1.5 18.3 11.1 15.1 1.7 19.5 10.7 318 5 314 165 1.2 0.2 1.6 0.7 02/19/2007 16:50:00 15.2 1.4 18.3 11.5 14.9 1.4 17.9 11.5 14.7 1.7 18.3 8.8 316 6 314 165 0.8 0.2 1.6 0.2 02/19/2007 17:00:00 14.7 1.5 19.5 11.1 14.4 1.5 18.3 10.3 14.3 1.9 19.5 9.1 318 8 325 165 0.8 0.1 1.4 0.4 02/19/2007 17:10:00 17.9 1.5 21.4 14.5 17.7 1.5 21 14.1 16.1 1.8 21 11.8 310 6 309 165 0.8 0.1 1.1 0.2 02/19/2007 17:20:00 17.7 2 22.1 12.6 17.4 2 21.8 12.2 16 1.7 20.2 11.8 311 6 308 165 0.3 0.1 0.7 -0.3 02/19/2007 17:30:00 16.3 1.6 21 12.6 15.9 1.5 20.6 12.2 15.8 1.8 21.4 11.1 318 6 315 165 0.2 0.1 0.7 -0.1 02/19/2007 17:40:00 14.4 1.9 18.7 10.3 14.1 1.9 18.7 9.9 13.8 2.3 19.5 9.1 315 7 316 165 0.1 0.2 0.7 -0.3 02/19/2007 17:50:00 15.5 1.6 19.5 11.5 15.2 1.5 18.7 11.8 14.6 1.9 19.1 9.5 317 7 315 165 0 0.2 0.4 -0.5 02/19/2007 18:00:00 15.3 1.3 19.1 11.1 15.1 1.3 18.7 11.1 14.6 1.6 19.9 9.9 316 7 322 165 0 0.2 0.2 -0.5 02/19/2007 18:10:00 15.6 1.4 19.5 12.2 15.3 1.4 19.1 12.2 14.6 1.7 18.3 10.3 315 7 312 165 -0.1 0 0.2 -0.5 02/19/2007 18:20:00 14 1.7 19.1 9.9 13.8 1.7 18.7 10.3 12.7 2 17.6 6.8 312 10 315 165 -0.1 0 0.2 -0.8 02/19/2007 18:30:00 12.7 1.9 18.3 8 12.6 1.8 17.9 8 11.7 1.8 17.6 6.1 312 8 316 165 -0.3 0.1 -0.1 -0.8 02/19/2007 18:40:00 14.2 1.6 18.3 9.5 14 1.6 18.3 9.5 13.2 1.8 17.9 8.8 315 10 302 165 -0.3 0.1 -0.1 -0.5 02/19/2007 18:50:00 14.3 1.8 19.1 9.9 14.1 1.8 19.1 9.9 14 1.8 19.5 8.4 323 9 312 165 -0.4 0.2 0.2 -1 02/19/2007 19:00:00 15.3 1.5 19.9 11.8 15 1.5 19.5 11.5 14.8 1.5 18.3 11.1 319 9 317 165 -0.4 0.2 -0.1 -0.8 02/19/2007 19:10:00 15.9 1.5 19.9 11.8 15.7 1.5 19.9 11.1 15.5 1.5 20.2 11.5 322 10 314 165 -0.5 0.1 -0.3 -1 02/19/2007 19:20:00 17 1.9 22.9 13 16.7 1.9 22.9 12.6 16.3 2 21 10.3 316 7 307 165 -0.6 0.1 -0.3 -1 02/19/2007 19:30:00 16.5 1.8 21.4 12.2 16.1 1.8 20.6 11.8 16.2 1.9 21.4 11.5 319 7 313 165 -0.6 0.1 -0.3 -1.2 02/19/2007 19:40:00 15.6 2.1 20.2 10.3 15.4 2 20.2 10.3 14.3 2.1 19.1 9.5 314 9 306 165 -0.8 0.2 -0.5 -1.4 02/19/2007 19:50:00 12.6 1.5 16.1 8 12.5 1.5 16.1 7.6 11.5 1.7 15.6 7.2 312 11 293 165 -0.8 0 -0.5 -1.4 02/19/2007 20:00:00 11.6 1.6 16.1 8 11.5 1.6 16.8 8 10.8 1.7 15.3 6.8 316 11 294 165 -0.8 0 -0.5 -1.2 02/19/2007 20:10:00 15 2 21.4 9.5 14.9 2 21.4 9.5 14 2.1 21.8 8.4 317 13 308 165 -0.6 0.1 -0.3 -1.2 02/19/2007 20:20:00 13.4 2.4 19.5 8 13.2 2.4 19.1 8 12.6 2.4 19.1 6.5 320 11 323 165 -0.6 0.1 -0.3 -1.2 02/19/2007 20:30:00 10.2 1.7 15.6 6.5 10.1 1.6 16.1 6.5 9.6 1.6 14.5 6.1 320 11 319 165 -0.8 0.1 -0.5 -1.2 02/19/2007 20:40:00 11.4 2 16.4 4.2 11.2 1.9 16.1 4.2 10.6 2.2 16.4 3.4 315 10 325 165 -1 0 -0.8 -1.4 02/19/2007 20:50:00 11.9 1.3 15.6 8.8 11.8 1.3 15.6 8.8 10.9 1.4 16.4 7.6 313 12 313 165 -1.1 0 -0.8 -1.4 02/19/2007 21:00:00 12.9 2.1 18.7 8.8 12.7 2.1 18.7 8 12.1 1.9 18.3 8 316 11 305 165 -1.3 0 -1 -1.4 02/19/2007 21:10:00 14.3 2.5 21 7.2 14.1 2.5 21 8 13.7 2.5 19.9 6.8 322 11 310 165 -1.2 0 -1 -1.4 02/19/2007 21:20:00 14.5 1.8 21.4 9.9 14.4 1.8 21.4 9.9 14 1.8 21 10.3 321 10 326 165 -1.1 0 -0.8 -1.4 02/19/2007 21:30:00 14.2 2 18.3 9.5 14 2.1 17.9 8.4 13.8 2.2 18.7 8.8 325 13 319 165 -1.3 0.1 -1 -1.4 02/19/2007 21:40:00 13.8 1.7 19.5 10.3 13.6 1.7 19.9 10.3 13.2 2 19.9 8.4 322 12 338 165 -1.4 0.1 -1.2 -1.7 02/19/2007 21:50:00 13.4 2.4 19.5 7.6 13.2 2.4 19.1 8 12.8 2.6 19.5 6.8 323 12 322 165 -1.3 0 -1 -1.4 02/19/2007 22:00:00 13 1.8 19.5 9.1 12.8 1.8 20.2 9.1 11.9 1.7 17.6 7.6 319 11 330 165 -1.5 0 -1.2 -1.7 02/19/2007 22:10:00 13.3 1.6 17.9 9.1 13.2 1.6 17.6 9.1 12.7 1.9 17.9 7.6 321 11 323 165 -1.6 0 -1.4 -1.9 02/19/2007 22:20:00 10.6 1.8 17.9 6.5 10.6 1.8 17.9 6.1 9.4 1.8 15.3 5.3 316 9 307 165 -1.8 0 -1.4 -2.1 02/19/2007 22:30:00 9.5 1.7 14.5 4.9 9.5 1.7 14.5 5.3 8.5 1.9 14.9 3.8 319 13 322 165 -2.1 0 -1.9 -2.6 02/19/2007 22:40:00 10.4 1.6 14.9 6.8 10.2 1.6 14.1 4.6 9.9 1.5 14.1 6.1 332 11 321 165 -2.2 0.2 -1.9 -2.6 02/19/2007 22:50:00 8.4 1 12.6 5.7 7.9 1.3 13 4.6 8 1 11.1 5.3 339 18 296 165 -2.6 0 -2.1 -2.8 02/19/2007 23:00:00 9.2 1.6 14.1 5.3 7.6 2.1 14.5 3.4 9.2 1.7 14.1 4.9 356 13 343 165 -3 0 -2.6 -3.3 02/19/2007 23:10:00 10.8 1.3 14.9 7.2 10.4 1.7 15.3 6.1 10.2 1.4 15.3 6.8 344 12 302 165 -3.3 0.1 -2.8 -3.5 02/19/2007 23:20:00 12.3 1.8 19.1 6.5 12 1.7 16.8 7.6 11.9 1.8 17.6 8.4 338 10 350 165 -2.7 0.1 -2.6 -3 02/19/2007 23:30:00 13.2 1.8 20.2 6.8 12.8 2.1 20.2 6.1 12.3 2 19.1 7.2 341 9 349 165 -2.8 0 -2.6 -3 02/19/2007 23:40:00 13.8 1.7 17.9 6.8 13.6 2 17.9 6.8 13 2.1 17.6 6.8 342 8 344 165 -3.1 0 -2.8 -3.3 02/19/2007 23:50:00 15.6 1.7 19.9 11.8 15.5 1.8 20.2 10.3 15.3 1.9 19.9 11.5 338 7 335 165 -3 0 -2.6 -3.3 02/20/2007 00:00:00 16.8 1.7 22.1 12.6 16.7 1.7 21.4 12.6 16.7 1.9 22.6 12.6 338 7 336 165 -2.9 0 -2.8 -3 02/20/2007 00:10:00 17.9 1.7 22.1 13.3 17.6 1.7 22.9 13.3 17.7 1.8 22.1 13.3 332 6 333 165 -3.1 0 -2.8 -3.3 02/20/2007 00:20:00 18.6 1.8 22.1 14.1 18.4 1.8 22.1 14.1 18.4 1.9 22.6 13.3 331 10 340 165 -2.9 0.2 -2.1 -3.3 02/20/2007 00:30:00 17.2 1.2 22.1 14.1 17 1.3 23.3 13.7 16.4 1.5 23.7 11.8 314 7 319 165 -2.4 0.1 -1.9 -2.6 02/20/2007 00:40:00 15.7 1.2 19.5 12.6 15.4 1.2 18.7 12.6 15.6 1.3 19.1 11.8 329 8 332 165 -2.9 0.1 -2.6 -3 02/20/2007 00:50:00 17.5 1.1 20.2 13.7 17.3 1.1 20.2 12.2 17.5 1.1 21 14.1 340 7 356 165 -2.9 0 -2.8 -3.3 02/20/2007 01:00:00 15.8 1.3 19.1 11.8 15.8 1.3 19.9 11.1 15.7 1.4 19.9 11.5 338 8 342 165 -2.9 0 -2.8 -3.3 02/20/2007 01:10:00 15.2 2 20.6 8.8 14.8 2.2 20.2 9.1 14.8 2.1 19.5 8 337 9 334 165 -2.8 0 -2.6 -3 02/20/2007 01:20:00 13.2 2.1 17.6 7.2 13.1 2 17.9 7.2 12.8 2.1 17.6 6.1 333 12 339 165 -2.9 0 -2.8 -3 02/20/2007 01:30:00 11.8 1.9 16.8 6.1 11.6 1.9 17.2 5.3 11.1 1.9 15.6 5.3 327 17 346 165 -3 0.1 -2.8 -3 02/20/2007 01:40:00 12.9 2 18.3 8.4 12.6 2.1 17.6 8 12 2.2 18.7 6.8 329 17 339 165 -3 0 -2.8 -3.3 02/20/2007 01:50:00 13 1.6 17.6 8.8 12.9 1.6 17.6 9.1 12.3 1.6 17.6 8.4 326 13 310 165 -3.1 0 -2.8 -3.3 02/20/2007 02:00:00 15 1.9 19.5 9.1 14.8 1.8 19.1 8.8 14.5 2 19.1 9.5 333 8 332 165 -3.2 0 -3 -3.3 02/20/2007 02:10:00 15.9 1.6 19.5 11.8 15.6 1.5 19.1 11.1 15.2 1.7 19.9 11.5 337 6 332 165 -3.2 0 -3 -3.3 02/20/2007 02:20:00 15.2 1.5 18.7 11.1 14.8 1.7 18.7 7.2 14.7 1.7 19.1 9.1 332 10 332 165 -3.3 0 -3 -3.5 02/20/2007 02:30:00 13.8 1.7 19.5 9.5 13.6 1.7 19.5 9.1 13 1.7 18.3 8 319 12 307 165 -3.3 0 -3 -3.5 02/20/2007 02:40:00 12.7 1.3 16.8 9.5 12.5 1.3 16.4 9.5 12.2 1.3 16.8 9.5 320 8 311 165 -3.5 0 -3.3 -3.7 02/20/2007 02:50:00 13.5 1.2 18.7 10.3 13.3 1.2 18.3 9.9 12.7 1.3 18.7 9.5 316 9 318 165 -3.7 0 -3.3 -3.9 02/20/2007 03:00:00 14.8 1.2 18.3 11.8 14.5 1.2 18.3 11.8 14.6 1.3 18.3 11.1 321 6 319 165 -3.5 0.1 -3.3 -3.9 02/20/2007 03:10:00 13.8 1.3 16.4 9.9 13.5 1.3 16.4 9.5 13.5 1.6 16.4 8.8 317 6 319 165 -3.5 0.1 -3.3 -3.9 02/20/2007 03:20:00 13.5 0.9 16.1 11.1 13.3 0.9 15.6 11.1 12.4 1.4 15.6 9.1 311 4 313 165 -4.2 0.1 -3.7 -4.4 02/20/2007 03:30:00 14.5 1 17.9 12.2 14.1 1 17.6 11.8 14 1.3 17.2 9.5 315 4 309 165 -4.3 0 -4.2 -4.6 02/20/2007 03:40:00 12.6 1 15.3 9.9 12.5 1 15.3 9.9 10.5 1.5 15.6 7.6 308 4 310 165 -4.4 0.1 -4.2 -4.6 02/20/2007 03:50:00 11.5 1 13.7 8.4 11.4 1 13.3 8 9.5 1 12.6 6.5 307 5 310 165 -4.7 0 -4.4 -4.8 02/20/2007 04:00:00 11.6 1 13.7 9.5 11.5 1 14.1 9.1 9.6 1.2 12.6 6.5 306 5 301 165 -4.8 0 -4.6 -5 02/20/2007 04:10:00 13.1 1.5 18.3 9.5 13 1.5 17.9 9.5 10.8 1.3 15.3 8.4 306 5 301 165 -4.7 0 -4.6 -5 02/20/2007 04:20:00 16.2 1.2 19.1 12.2 15.9 1.2 18.7 11.8 14.7 1.7 18.7 9.1 311 6 296 165 -4.6 0 -4.4 -4.8 02/20/2007 04:30:00 17.4 1.1 20.2 14.1 17 1 19.9 13.7 16.4 1.2 20.2 12.6 313 5 304 165 -4.6 0 -4.4 -4.6 02/20/2007 04:40:00 17.5 1 19.5 13.7 17.1 1 19.5 13.3 17.4 1 19.9 13.3 318 4 318 165 -4.8 0 -4.6 -5 02/20/2007 04:50:00 16.3 1 19.5 13.7 16 1 19.1 13.7 16 1.2 19.9 12.2 316 5 316 165 -4.9 0 -4.6 -5 02/20/2007 05:00:00 15.8 1.4 19.1 11.8 15.6 1.4 18.7 11.5 15.4 1.4 18.3 11.1 318 7 312 165 -5.2 0.1 -5 -5.5 02/20/2007 05:10:00 15.1 1.5 18.3 9.5 14.8 1.4 17.9 9.1 14.5 1.5 17.9 9.1 315 6 312 165 -5.6 0.1 -5.3 -5.7 02/20/2007 05:20:00 15.7 1.5 18.7 11.8 15.4 1.5 18.7 11.5 14.5 1.7 19.9 8.8 311 6 309 165 -5.8 0.1 -5.5 -5.9 02/20/2007 05:30:00 14.7 1.3 17.6 11.5 14.5 1.3 17.2 11.1 12.6 1.6 17.6 8.8 307 5 302 165 -6 0 -5.7 -6.1 02/20/2007 05:40:00 13 1.7 16.8 8.4 12.9 1.7 16.8 8.8 10.2 1.7 14.9 6.8 301 6 306 165 -6 0 -5.9 -6.1 02/20/2007 05:50:00 10.5 1.7 15.3 6.5 10.4 1.6 15.6 6.5 8.8 1.7 14.5 4.2 292 9 296 165 -6 0 -5.7 -6.1 02/20/2007 06:00:00 6.7 2 11.1 2.3 6.7 2 11.1 2.3 5.8 1.7 10.3 2.3 309 18 295 165 -5.9 0.1 -5.5 -6.1 02/20/2007 06:10:00 8.4 1.7 13.3 4.2 8.2 1.7 13 4.2 7.8 1.7 12.6 3.8 327 17 334 165 -5.3 0.2 -4.8 -5.7 02/20/2007 06:20:00 10.6 1.7 16.1 6.1 10.6 1.7 16.4 6.5 9.2 1.9 14.9 3.4 315 14 311 165 -5.2 0.1 -5 -5.5 02/20/2007 06:30:00 12.4 2.4 19.1 6.5 12.5 2.4 20.2 7.2 10.6 2.3 16.4 4.9 310 11 289 165 -5.1 0.1 -4.8 -5.3 02/20/2007 06:40:00 16.7 2.4 22.1 11.1 16.5 2.4 21.8 11.1 16 2.4 21.4 8.4 319 11 318 165 -5 0.1 -4.6 -5.5 02/20/2007 06:50:00 19.5 2.1 24 14.5 19.2 2.1 24 14.1 17.9 1.8 22.6 12.6 312 8 298 165 -5.4 0.2 -4.6 -5.7 02/20/2007 07:00:00 16.4 1.9 21.4 12.2 16.2 1.9 21.4 12.2 15.2 1.7 19.5 9.9 314 11 292 165 -5.3 0.2 -4.6 -5.7 02/20/2007 07:10:00 20.2 2.6 28.3 14.5 19.9 2.6 27.9 14.5 17.6 2.3 24 11.5 307 7 312 165 -5.7 0 -5.5 -5.7 02/20/2007 07:20:00 20.9 2.1 25.6 12.6 20.7 2.1 25.6 13 19.7 2.1 24 11.8 310 8 301 165 -5.7 0 -5.5 -5.9 02/20/2007 07:30:00 22.1 1.7 28.3 16.8 21.8 1.7 27.5 16.8 20.5 2.1 27.9 15.3 308 8 309 165 -5.8 0 -5.7 -6.1 02/20/2007 07:40:00 24.3 1.7 28.7 19.1 24 1.7 27.9 18.7 23.5 2 29.4 17.9 311 6 312 165 -5.9 0 -5.7 -6.1 02/20/2007 07:50:00 21.6 2.4 27.5 15.3 21.2 2.4 27.1 14.9 21 2.3 26.3 14.1 314 6 311 165 -6.2 0 -5.9 -6.4 02/20/2007 08:00:00 23.1 2.3 27.5 15.6 22.8 2.3 27.1 16.1 22.6 2.5 27.5 14.5 316 7 317 165 -6.1 0 -5.7 -6.4 02/20/2007 08:10:00 21.8 1.7 26.3 17.2 21.5 1.7 26 17.2 21 1.8 26.3 16.4 313 6 312 165 -6.2 0 -5.9 -6.4 02/20/2007 08:20:00 22.8 2 27.5 17.2 22.5 2 27.1 17.2 21 2.1 25.2 13.7 308 6 307 165 -6.1 0 -5.9 -6.4 02/20/2007 08:30:00 21.9 1.8 26.3 17.2 21.6 1.8 26.3 16.8 18.9 1.9 24.4 13 305 7 316 165 -5.9 0.1 -5.5 -6.1 02/20/2007 08:40:00 22 1.7 26.8 18.3 21.7 1.6 27.5 17.9 18.6 2 24 13.3 304 6 312 165 -6.1 0 -5.9 -6.4 02/20/2007 08:50:00 22.7 1.8 27.1 17.6 22.4 1.8 26.8 17.6 20 2.1 24.4 14.5 304 7 308 165 -6.2 0 -5.9 -6.4 02/20/2007 09:00:00 22.5 1.5 26.3 19.1 22.2 1.5 26 18.7 20 1.7 25.6 14.9 306 6 301 165 -6 0 -5.7 -6.1 02/20/2007 09:10:00 23.9 1.9 27.5 17.2 23.6 1.8 27.5 17.6 21.3 2.2 26.3 15.3 306 6 302 165 -5.9 0 -5.7 -6.1 02/20/2007 09:20:00 24.6 1.6 28.7 20.2 24.3 1.6 28.7 19.9 23.4 1.7 28.3 19.5 309 6 311 165 -6 0 -5.7 -6.1 02/20/2007 09:30:00 23.6 1.7 29.1 17.9 23.3 1.7 29.1 17.6 22.7 1.9 29.1 18.3 311 6 315 165 -6.2 0 -5.9 -6.4 02/20/2007 09:40:00 23.7 1.7 28.7 18.3 23.4 1.6 27.9 18.3 22.5 1.5 26.8 17.9 309 6 303 165 -6.4 0 -6.1 -6.6 02/20/2007 09:50:00 22.9 1.6 26.3 18.7 22.5 1.5 26.3 18.7 21.9 1.9 27.1 15.6 311 6 317 165 -6.4 0 -6.1 -6.6 02/20/2007 10:00:00 22.3 1.7 26 17.6 21.9 1.6 25.6 17.6 21.9 1.8 26.3 17.9 314 6 306 165 -6.5 0 -6.4 -6.6 02/20/2007 10:10:00 21.7 1.3 25.2 18.3 21.3 1.3 25.2 18.3 21.4 1.4 26.3 18.3 316 7 323 165 -6.4 0 -6.1 -6.6 02/20/2007 10:20:00 21.1 1.7 24.8 16.4 20.7 1.7 24.8 16.4 20.9 1.8 25.6 15.6 317 6 316 165 -6.4 0 -6.1 -6.6 02/20/2007 10:30:00 21 1.2 24.4 16.8 20.6 1.2 24 16.8 20.7 1.5 24.8 15.3 317 7 321 165 -6.4 0 -6.1 -6.6 02/20/2007 10:40:00 22.3 1.5 26.3 17.9 21.9 1.5 26.3 17.6 22.3 1.5 26 17.2 317 5 287 165 -6.2 0 -5.9 -6.4 02/20/2007 10:50:00 22.2 1.3 25.2 19.1 21.8 1.3 25.2 18.7 22.2 1.3 25.2 18.3 317 4 310 165 -6.2 0 -5.9 -6.4 02/20/2007 11:00:00 21.3 1.4 24.4 17.2 20.9 1.4 24 17.2 21 1.6 24.8 16.4 318 6 317 165 -5.9 0 -5.7 -6.4 02/20/2007 11:10:00 19.5 1.4 23.3 15.6 19.1 1.3 22.9 15.6 19.1 1.5 23.3 14.5 319 7 318 165 -5.8 0 -5.7 -6.1 02/20/2007 11:20:00 18.5 1.7 22.1 12.6 18.1 1.7 21.4 12.2 17.8 1.7 22.1 12.6 314 6 323 165 -5.9 0 -5.7 -6.1 02/20/2007 11:30:00 15.6 1.7 20.2 12.2 15.3 1.7 19.5 11.8 14.8 2.3 19.1 9.1 313 7 318 165 -5.8 0 -5.5 -5.9 02/20/2007 11:40:00 16.1 1.2 19.1 13 15.8 1.2 18.7 12.6 15 1.4 19.5 10.7 311 6 313 165 -5.8 0 -5.7 -6.1 02/20/2007 11:50:00 17.2 1.5 22.1 13.7 16.9 1.5 21.8 13 16.1 1.7 21 11.1 311 6 309 165 -5.8 0 -5.7 -5.9 02/20/2007 12:00:00 18.3 1.9 22.9 14.1 17.9 1.9 22.9 13.3 17.2 2.1 22.9 11.5 312 6 314 165 -5.8 0 -5.7 -5.9 02/20/2007 12:10:00 18.6 1.6 22.6 14.5 18.2 1.6 22.6 14.1 18.2 1.7 22.9 12.6 315 6 311 165 -5.8 0 -5.7 -5.9 02/20/2007 12:20:00 21.2 1.7 24 16.4 20.8 1.6 24 16.4 20.6 1.7 24.8 14.9 313 6 320 165 -5.8 0 -5.7 -5.9 02/20/2007 12:30:00 19.7 2.2 24 13.3 19.4 2.1 23.7 13.3 19 2.2 24 13.7 314 7 312 165 -5.8 0.1 -5.5 -5.9 02/20/2007 12:40:00 18.6 1.5 22.9 14.5 18.3 1.5 22.6 14.5 17.9 1.8 22.6 13.3 313 8 311 165 -5.6 0 -5.5 -5.7 02/20/2007 12:50:00 21.1 1.6 25.2 16.4 20.8 1.6 24.8 16.4 20.1 1.9 26 15.3 311 7 317 165 -5.7 0 -5.5 -5.7 02/20/2007 13:00:00 19.9 1.7 24 15.6 19.7 1.6 24 15.6 19.5 1.9 24.8 12.2 316 9 314 165 -5.6 0 -5.5 -5.7 02/20/2007 13:10:00 20.2 1.3 24 16.1 19.9 1.3 23.3 15.3 19.6 1.5 23.7 15.6 313 8 310 165 -5.6 0 -5.5 -6.1 02/20/2007 13:20:00 19.8 1.7 26.3 16.4 19.6 1.7 26.8 16.1 19.5 1.9 25.2 14.9 316 7 311 165 -5.6 0 -5.5 -5.9 02/20/2007 13:30:00 19.3 1.9 24.4 13.7 19.2 1.9 24 13.7 18.8 2 24.4 13 316 10 303 165 -5.4 0.1 -5 -5.7 02/20/2007 13:40:00 18.3 2.3 24.4 13 18.1 2.3 24.4 13 17.8 2.2 24.4 12.6 316 10 310 165 -5.3 0.1 -5 -5.9 02/20/2007 13:50:00 19 2.5 27.1 13.3 18.9 2.5 26.8 13 18.3 2.9 28.3 11.8 313 12 307 165 -5.3 0.1 -5 -5.7 02/20/2007 14:00:00 17.7 2.7 25.6 10.7 17.6 2.6 25.2 9.9 16.4 2.6 24.8 11.1 314 17 292 165 -5.4 0.1 -5 -5.7 02/20/2007 14:10:00 16.5 3.1 25.6 8.8 16.4 3.1 25.2 8.4 15.2 3.1 24.8 8.4 312 13 314 165 -5.4 0.1 -5.3 -5.7 02/20/2007 14:20:00 16.2 2.6 22.1 9.9 16.1 2.6 21.8 9.9 15.4 2.7 21.8 8 316 14 313 165 -5.4 0.1 -5 -5.7 02/20/2007 14:30:00 12.6 2.4 20.6 7.2 12.3 2.4 21.4 6.8 11.9 2.4 18.7 6.8 326 17 313 165 -5 0.2 -4.6 -5.5 02/20/2007 14:40:00 11.9 2.8 22.6 5.3 11.5 2.9 22.9 4.6 10.8 2.7 18.7 4.6 327 21 292 165 -4.4 0.1 -4.2 -4.8 02/20/2007 14:50:00 16.7 4.1 26.8 5.7 16.6 4.1 27.9 5.7 15 4.3 26.3 5.3 312 14 305 165 -4.7 0.2 -4.2 -5 02/20/2007 15:00:00 17.2 3.3 25.2 8.4 17.2 3.3 25.2 8.8 15.2 3.2 23.3 5.7 308 11 309 165 -5.1 0.2 -4.6 -5.7 02/20/2007 15:10:00 16.6 3.6 26 7.6 16.7 3.5 25.6 8.4 14.8 3.8 25.6 6.1 313 14 293 165 -5.3 0 -5 -5.7 02/20/2007 15:20:00 16.5 3.2 24.8 8.8 16.6 3.2 25.2 8.8 15 3.6 24.4 6.5 315 13 313 165 -5.4 0.2 -5 -6.1 02/20/2007 15:30:00 18.5 2.7 25.6 11.1 18.3 2.8 25.6 10.3 17.2 2.6 23.7 6.8 314 12 307 165 -5.7 0.3 -5 -6.4 02/20/2007 15:40:00 21.7 2.8 28.7 13 21.5 2.7 28.7 13.3 20.7 2.9 28.7 12.2 312 9 311 165 -6.1 0.1 -5.9 -6.6 02/20/2007 15:50:00 22.1 2.4 28.7 16.1 21.9 2.4 29.1 15.3 21.1 2.4 26.3 13.3 310 9 308 165 -6.4 0 -6.1 -6.6 02/20/2007 16:00:00 21.5 2.7 30.2 14.1 21.3 2.7 29.4 14.5 20.5 2.7 27.9 13.3 309 9 294 165 -6.6 0 -6.4 -6.8 02/20/2007 16:10:00 23.5 2.4 30.9 15.6 23.3 2.4 30.9 15.6 22.3 2.7 32.4 14.5 310 10 318 165 -6.6 0 -6.6 -6.8 02/20/2007 16:20:00 22.5 2.4 28.3 15.3 22.3 2.4 28.3 16.1 21.8 2.8 30.9 13.3 314 10 325 165 -6.6 0 -6.6 -6.8 02/20/2007 16:30:00 21.1 2.7 28.7 13.7 20.9 2.6 28.3 14.1 19.6 3.1 28.7 12.6 310 12 322 165 -6.5 0 -6.1 -6.8 02/20/2007 16:40:00 17.3 2.7 24.4 11.1 17.2 2.7 26 10.7 16.1 2.5 24 11.1 313 15 310 165 -6.3 0 -5.9 -6.6 02/20/2007 16:50:00 18.1 2.3 26 11.5 17.9 2.3 26 11.8 16.9 2.4 24.4 11.1 311 10 319 165 -6.4 0 -6.1 -6.6 02/20/2007 17:00:00 20.1 2.7 31.8 13.7 19.9 2.7 31.3 13.3 19.2 2.6 27.5 12.6 313 11 299 165 -6.4 0 -6.1 -6.6 02/20/2007 17:10:00 20.4 2.4 26.8 15.3 20.2 2.5 26.8 14.5 19.8 2.6 25.6 13.7 318 13 311 165 -6.4 0 -6.1 -6.6 02/20/2007 17:20:00 21.5 2.2 28.7 16.8 21.2 2.3 29.1 16.4 20.9 2.4 29.4 15.6 318 11 318 165 -6.7 0 -6.6 -6.8 02/20/2007 17:30:00 23.4 2.7 29.4 14.1 23.2 2.6 29.1 14.5 22.9 2.7 28.3 14.9 318 12 321 165 -6.9 0 -6.6 -7.2 02/20/2007 17:40:00 24.4 2.8 30.2 15.3 24.2 2.7 30.2 14.9 23.9 3.1 30.6 15.6 315 10 319 165 -7.1 0 -6.8 -7.2 02/20/2007 17:50:00 25.1 2.7 31.8 17.9 24.9 2.7 31.8 17.6 24.8 3.1 32.4 16.4 316 10 314 165 -7.1 0 -6.8 -7.2 02/20/2007 18:00:00 24.5 2.8 32.9 18.7 24.4 2.8 32.9 18.3 24.4 2.9 33.2 16.1 318 11 295 165 -7 0 -6.8 -7.2 02/20/2007 18:10:00 21.5 3.1 29.1 14.9 21.4 3.1 28.7 14.5 20.9 3.3 30.2 13.3 315 13 319 165 -7.1 0 -6.8 -7.2 02/20/2007 18:20:00 22.8 2.8 31.3 14.5 22.6 2.8 30.9 14.1 22.3 2.9 29.8 14.1 314 10 307 165 -7.2 0 -6.8 -7.4 02/20/2007 18:30:00 24.7 3.1 35.5 17.2 24.5 3.1 35.2 17.6 24.1 2.8 31.3 17.6 311 10 319 165 -7.3 0 -7.2 -7.4 02/20/2007 18:40:00 25.2 2.6 32.1 17.6 25 2.6 31.8 18.3 24.4 2.9 32.1 17.6 312 9 305 165 -7.3 0 -7.2 -7.4 02/20/2007 18:50:00 25.5 2.4 30.6 17.2 25.2 2.4 31.3 18.3 25.3 2.7 31.8 17.2 315 9 307 165 -7.3 0.1 -7.2 -7.6 02/20/2007 19:00:00 25.8 2.9 34 18.3 25.6 2.9 33.6 17.9 25.3 2.9 33.2 17.6 314 11 319 165 -7.5 0 -7.2 -7.6 02/20/2007 19:10:00 25.1 2.4 32.1 19.1 24.9 2.4 31.8 19.5 25 2.6 32.9 18.7 315 9 323 165 -7.5 0 -7.2 -7.6 02/20/2007 19:20:00 25.2 2.6 32.4 19.1 24.9 2.7 32.9 17.9 25.1 2.9 33.2 17.9 317 11 314 165 -7.5 0 -7.2 -7.6 02/20/2007 19:30:00 26.5 2.3 32.4 21.4 26.2 2.3 32.1 21 26.5 2.4 33.2 21 319 9 326 165 -7.6 0 -7.4 -7.9 02/20/2007 19:40:00 27.1 1.9 32.9 20.6 26.9 2 32.9 20.6 27.1 2 32.9 20.2 312 8 319 165 -7.6 0 -7.6 -8.1 02/20/2007 19:50:00 27.8 2 33.6 22.9 27.5 2 32.9 22.1 27.9 2.3 34 21.4 314 6 310 165 -7.8 0 -7.6 -8.1 02/20/2007 20:00:00 26 2.3 31.3 17.9 25.8 2.3 30.6 18.3 25.8 2.4 31.8 18.7 315 9 308 165 -7.8 0 -7.6 -8.1 02/20/2007 20:10:00 24.5 1.9 29.4 18.3 24.3 2 29.8 18.3 24 1.9 29.1 18.3 312 9 307 165 -7.8 0 -7.4 -7.9 02/20/2007 20:20:00 25.3 2 30.2 19.9 25 2 30.6 19.5 25.3 2 30.2 19.5 316 9 310 165 -7.8 0 -7.6 -7.9 02/20/2007 20:30:00 24.4 2 30.6 18.3 24.1 2 29.8 18.3 24.2 2.3 30.9 17.6 315 8 332 165 -7.9 0 -7.6 -8.1 02/20/2007 20:40:00 21.3 2.6 29.8 13 21.2 2.6 29.1 12.6 20.9 2.7 29.1 12.6 318 11 310 165 -7.8 0 -7.6 -8.1 02/20/2007 20:50:00 21.5 2.5 27.1 14.9 21.4 2.5 26.8 14.5 20.5 2.7 28.3 13.3 313 8 316 165 -7.9 0 -7.6 -8.1 02/20/2007 21:00:00 24.7 2.4 33.2 19.5 24.5 2.3 32.9 18.7 24.2 2.6 34.8 18.7 315 8 317 165 -7.8 0 -7.4 -8.1 02/20/2007 21:10:00 26.3 2.4 33.6 19.9 26 2.3 33.2 19.9 25.9 2.7 33.6 19.5 315 8 311 165 -7.6 0 -7.4 -7.9 02/20/2007 21:20:00 24.2 2.1 29.1 18.3 24 2.1 29.1 18.7 23.8 2.3 28.3 17.6 315 8 309 165 -7.6 0 -7.4 -7.9 02/20/2007 21:30:00 22.8 1.7 28.3 17.9 22.5 1.8 28.7 17.6 22.5 2 29.8 16.4 315 8 326 165 -7.5 0.1 -7.2 -7.6 02/20/2007 21:40:00 22.5 1.9 29.1 17.6 22.2 1.9 29.1 16.8 21.9 2.1 29.8 17.2 314 9 305 165 -7.5 0 -7.4 -7.6 02/20/2007 21:50:00 23.3 1.8 28.7 19.1 23 1.8 28.7 18.3 22.5 2.1 29.1 16.4 312 7 317 165 -7.6 0 -7.4 -7.6 02/20/2007 22:00:00 23.9 1.9 29.4 18.7 23.6 1.8 28.7 17.9 22.3 2.1 26.8 15.3 307 6 305 165 -7.6 0 -7.4 -7.9 02/20/2007 22:10:00 20.5 2.2 25.2 16.1 20.3 2.2 25.2 15.6 19.4 2.2 25.2 12.6 310 9 306 165 -7.6 0 -7.4 -7.9 02/20/2007 22:20:00 18.3 2.3 25.6 12.6 18 2.3 25.6 12.6 17.3 2 23.7 11.5 311 9 310 165 -7.6 0.1 -7.4 -7.9 02/20/2007 22:30:00 17.4 2 22.9 13 17.2 1.9 22.6 13 16.4 1.8 22.1 11.8 313 13 300 165 -7.5 0 -7.4 -7.6 02/20/2007 22:40:00 16.9 2 22.9 11.8 16.7 2 22.6 11.8 16.4 2.2 22.6 11.8 318 13 328 165 -7.5 0 -7.2 -7.6 02/20/2007 22:50:00 14.2 2.3 20.6 8.8 14.1 2.3 21 8.4 13.6 2.5 21 6.8 318 15 316 165 -7.4 0 -7 -7.6 02/20/2007 23:00:00 13.2 2.3 19.5 6.1 13 2.3 19.5 6.1 12.1 2.4 21 6.8 311 12 315 165 -7.4 0.1 -7.2 -7.6 02/20/2007 23:10:00 13.1 2.1 17.9 8 12.9 2.1 17.9 7.6 11.7 2 17.6 6.5 308 10 298 165 -7.3 0 -6.8 -7.4 02/20/2007 23:20:00 15 2.4 21.8 9.9 14.8 2.4 21 9.9 14.2 2.7 20.6 8.8 312 11 317 165 -7.2 0 -6.8 -7.4 02/20/2007 23:30:00 15.6 1.7 21 11.5 15.4 1.7 21.4 11.1 15.2 2 20.2 9.9 316 11 332 165 -7.3 0 -7 -7.4 02/20/2007 23:40:00 14.7 2.4 21.8 9.9 14.5 2.4 21.4 9.1 14.3 2.3 21.8 9.9 319 13 334 165 -7.4 0 -7.2 -7.4 02/20/2007 23:50:00 14.6 3.1 23.7 9.1 14.4 3.2 24 8.8 14.4 3.3 24 9.1 328 16 349 165 -7.3 0 -7 -7.4 02/21/2007 00:00:00 15.6 2.5 21.8 10.7 15.4 2.6 21.8 9.9 14.5 2.7 22.1 9.1 310 10 315 165 -7.2 0.1 -6.8 -7.4 02/21/2007 00:10:00 18.1 2.6 25.2 11.1 17.7 2.7 25.6 10.7 18.1 2.7 24.8 11.1 334 13 355 165 -7.1 0 -6.8 -7.2 02/21/2007 00:20:00 15.3 1.8 20.6 11.1 15.1 1.9 20.2 11.1 14.4 2 19.1 8.8 322 19 307 165 -7.2 0 -6.8 -7.4 02/21/2007 00:30:00 12.1 1.7 16.4 6.8 11.9 1.7 16.8 6.5 11.4 2.1 16.1 6.8 322 18 338 165 -7.3 0 -7.2 -7.6 02/21/2007 00:40:00 11.7 1.8 15.6 6.8 11.5 1.7 15.6 6.8 10.5 1.7 16.1 5.7 310 15 294 165 -7.3 0.1 -6.8 -7.6 02/21/2007 00:50:00 12.7 1.7 17.2 7.6 12.6 1.7 17.2 7.2 11.3 1.6 16.8 7.6 307 10 304 165 -7.1 0 -6.8 -7.2 02/21/2007 01:00:00 11.7 1.5 16.8 8 11.5 1.5 16.1 7.6 11.3 1.8 15.6 6.1 325 15 319 165 -7.1 0 -6.8 -7.4 02/21/2007 01:10:00 10.7 1.5 16.4 7.2 10.3 1.6 16.4 6.8 10.6 1.5 16.1 6.8 337 13 343 165 -7.4 0.1 -7.2 -7.4 02/21/2007 01:20:00 10.7 1.3 15.3 7.6 10.1 1.7 15.3 4.6 10.7 1.3 14.9 6.5 345 8 332 165 -7.4 0 -7.2 -7.6 02/21/2007 01:30:00 12.8 1.7 17.9 8.4 12 2.4 17.6 6.1 12.7 1.8 17.6 7.6 345 11 353 165 -7.4 0 -7.2 -7.4 02/21/2007 01:40:00 14.8 1.9 19.1 9.9 14.7 2.1 19.1 9.9 14.7 2 19.1 9.5 340 8 344 165 -7.4 0 -7.2 -7.6 02/21/2007 01:50:00 17.7 2 22.9 12.6 17.6 2.2 22.6 10.7 17.5 2.3 23.3 11.5 336 12 336 165 -7.3 0 -7.2 -7.6 02/21/2007 02:00:00 16.9 2.2 22.1 10.3 16.7 2.6 22.9 7.2 16.6 2.5 23.3 8 336 12 352 165 -7.4 0.1 -7.2 -7.4 02/21/2007 02:10:00 20.6 1.5 24.4 16.4 20.6 1.7 25.2 15.6 20.2 1.7 24 14.5 340 5 338 165 -7.5 0 -7.2 -7.6 02/21/2007 02:20:00 20 1.6 24 14.5 19.9 1.8 24.8 13.3 19.7 1.7 24.8 14.5 341 5 342 165 -7.5 0 -7.4 -7.6 02/21/2007 02:30:00 20.6 2 25.2 14.9 20.6 2.2 25.2 14.9 20.6 2 25.2 14.9 336 8 346 165 -7.6 0 -7.4 -7.9 02/21/2007 02:40:00 21.3 2.2 26.8 14.9 21.2 2.4 27.5 14.1 21.2 2.2 26 13.3 339 7 343 165 -7.7 0 -7.4 -7.9 02/21/2007 02:50:00 21.6 2 28.7 16.1 21.4 1.9 27.1 15.3 21.6 2.1 27.9 15.6 337 9 358 165 -7.6 0 -7.4 -7.9 02/21/2007 03:00:00 22.5 2.1 28.7 17.2 22.4 2.3 29.1 17.2 22.4 2.2 28.3 15.6 338 8 341 165 -7.8 0 -7.4 -8.1 02/21/2007 03:10:00 22.8 1.6 27.5 18.3 22.8 1.9 28.3 17.2 23 1.6 27.9 17.6 339 7 343 165 -7.8 0 -7.6 -8.1 02/21/2007 03:20:00 21.7 1.9 26 16.4 21.4 2.3 27.9 15.3 21.6 2.2 27.1 16.4 338 9 350 165 -7.9 0 -7.6 -8.1 02/21/2007 03:30:00 19.4 1.5 23.7 15.3 19.1 1.6 23.3 14.5 19.3 1.7 25.2 14.1 332 9 321 165 -8 0 -7.6 -8.1 02/21/2007 03:40:00 20.3 1.5 23.7 16.1 20.1 1.6 23.7 16.1 20.2 1.5 23.3 15.6 333 12 350 165 -8 0 -7.9 -8.1 02/21/2007 03:50:00 18.4 1.4 22.6 14.5 18.1 1.4 22.1 14.5 18.1 1.7 22.6 13.7 322 9 317 165 -8.1 0 -7.9 -8.3 02/21/2007 04:00:00 18.2 1.7 23.7 14.1 17.9 1.7 23.3 13.7 18.3 1.9 24.8 13.7 326 11 311 165 -8.1 0 -7.9 -8.3 02/21/2007 04:10:00 19.6 1.7 24 14.9 19.4 1.9 23.7 14.5 19.5 2 25.2 15.6 336 8 329 165 -8.1 0 -7.9 -8.5 02/21/2007 04:20:00 18.9 1.7 23.7 15.3 18.6 1.7 23.3 14.9 18.8 1.9 24.8 14.9 323 11 329 165 -8.1 0 -7.9 -8.3 02/21/2007 04:30:00 19.6 1.8 24.8 14.5 19.3 1.9 25.2 14.1 19.6 1.9 25.6 14.5 327 11 342 165 -8 0 -7.9 -8.3 02/21/2007 04:40:00 20.5 1.8 24.8 16.4 20.5 2 25.2 16.1 20.3 2 24.4 15.6 337 9 342 165 -8.1 0 -8.1 -8.3 02/21/2007 04:50:00 19.9 2.2 25.6 14.1 19.5 2.3 26.3 14.1 19.8 2.2 24.4 14.5 334 11 331 165 -8.2 0 -8.1 -8.5 02/21/2007 05:00:00 19.7 2.1 25.2 14.9 19.5 2 25.2 14.5 18.9 2.3 23.3 11.5 317 17 293 165 -8.2 0.1 -8.1 -8.5 02/21/2007 05:10:00 20.1 2 24.8 14.9 19.9 2 25.2 14.5 19.7 2.4 27.1 13.7 317 11 315 165 -8 0.1 -7.6 -8.3 02/21/2007 05:20:00 16 1.7 21.8 12.2 15.7 1.8 22.6 10.7 15.6 1.7 21 10.7 328 13 347 165 -8.1 0 -8.1 -8.3 02/21/2007 05:30:00 17.6 1.8 22.9 13 16.8 2.5 22.6 9.1 17.4 1.7 21.8 12.6 343 10 332 165 -8.1 0 -7.9 -8.3 02/21/2007 05:40:00 16.6 2.3 23.3 11.1 16.3 2.6 24.4 9.9 16.3 2.5 24 11.5 341 9 347 165 -8.1 0 -8.1 -8.3 02/21/2007 05:50:00 15.9 2.2 22.1 10.7 15.3 2.7 21 6.8 16 2.3 21.4 9.5 343 9 354 165 -8 0 -7.6 -8.1 02/21/2007 06:00:00 16.1 1.7 19.9 11.8 15.3 2.6 21 8 16 1.7 20.6 11.8 341 11 340 165 -8 0 -7.6 -8.1 02/21/2007 06:10:00 16.6 1.7 20.6 12.2 16.1 2.3 21 9.5 16.4 1.7 20.2 11.5 345 8 341 165 -8 0.1 -7.6 -8.1 02/21/2007 06:20:00 14.9 2.2 22.9 9.5 14.9 2.3 22.9 9.5 14.3 2.2 19.5 9.5 337 8 341 165 -8 0 -7.6 -8.1 02/21/2007 06:30:00 14.9 2.3 20.6 10.3 14.6 2.4 21 7.6 14.4 2.4 21 9.5 341 10 341 165 -8 0 -7.6 -8.1 02/21/2007 06:40:00 11.9 2.3 18.7 6.8 11.9 2.4 19.9 6.8 11.2 2.1 17.2 6.8 335 9 339 165 -8 0 -7.6 -8.1 02/21/2007 06:50:00 12.7 1.5 16.1 8.8 12.5 1.5 15.6 7.6 12.1 1.6 16.1 7.6 330 13 339 165 -8.1 0 -7.9 -8.3 02/21/2007 07:00:00 14.4 1.4 17.9 10.7 14.2 1.5 18.3 10.7 14.2 1.4 18.3 10.7 328 12 340 165 -8.1 0.1 -7.6 -8.5 02/21/2007 07:10:00 13 1.4 16.1 9.1 12.8 1.4 16.4 8.8 12.7 1.4 16.4 8.8 329 10 300 165 -8 0 -7.6 -8.1 02/21/2007 07:20:00 13.5 1.3 19.9 10.3 13.4 1.3 19.5 9.9 13.2 1.3 18.3 9.9 330 12 319 165 -8.1 0 -8.1 -8.5 02/21/2007 07:30:00 14.1 1.3 17.2 10.7 13.9 1.3 17.2 9.9 13.5 1.7 17.2 7.6 322 10 319 165 -8.2 0 -8.1 -8.5 02/21/2007 07:40:00 14 1.8 18.3 9.1 13.7 2 18.7 9.1 13.4 1.7 17.9 9.1 337 10 333 165 -8.2 0 -8.1 -8.5 02/21/2007 07:50:00 13.3 1.3 17.2 9.9 13.1 1.4 16.8 9.1 12.9 1.3 16.8 9.5 331 11 334 165 -8.3 0 -8.1 -8.5 02/21/2007 08:00:00 14.5 1.3 17.6 11.1 14.4 1.5 17.9 10.3 13.9 1.4 17.2 10.3 338 8 309 165 -8.3 0 -8.1 -8.5 02/21/2007 08:10:00 14.1 1.7 19.5 10.7 14 1.8 19.5 10.3 13.4 1.7 18.7 9.5 339 9 339 165 -8.3 0 -8.1 -8.5 02/21/2007 08:20:00 12.5 1.6 16.4 8 12.4 1.6 16.8 8 12.1 1.7 15.6 6.8 328 15 310 165 -8.3 0 -8.1 -8.5 02/21/2007 08:30:00 11.7 1.2 15.3 7.6 11.5 1.2 14.9 7.2 11 1.3 14.5 6.8 325 13 318 165 -8.3 0 -8.1 -8.7 02/21/2007 08:40:00 12.4 1.7 18.7 8 11.8 1.5 16.1 8 11.7 1.7 18.7 8 337 13 347 165 -8.1 0.1 -7.6 -8.3 02/21/2007 08:50:00 12.2 1.7 16.4 6.5 11.7 2 16.4 5.7 11.1 1.9 15.6 6.1 343 10 347 165 -7.8 0 -7.4 -8.1 02/21/2007 09:00:00 10.3 1.9 15.3 5.7 9.7 1.9 14.5 4.9 9.4 1.8 14.1 4.9 342 12 347 165 -7.5 0.1 -7.2 -7.6 02/21/2007 09:10:00 8.2 1.9 14.1 3.8 8 2.1 14.1 3.4 7.5 2.2 14.1 2.3 336 14 342 165 -7.3 0.1 -6.8 -7.4 02/21/2007 09:20:00 8.5 1.7 14.5 5.3 7.8 1.7 14.5 4.6 7.8 1.7 13 4.2 344 10 345 165 -7 0 -6.8 -7.2 02/21/2007 09:30:00 7.3 1.7 12.2 4.2 6.5 1.6 11.8 3 6.8 1.7 11.8 3 342 16 356 165 -6.9 0 -6.6 -7.2 02/21/2007 09:40:00 8 1.7 12.6 3.4 7.3 1.9 13 3.4 7.6 1.7 11.8 2.3 344 14 347 165 -6.7 0.1 -6.6 -7.2 02/21/2007 09:50:00 11 1.7 16.1 7.2 10.5 2 16.4 5.7 10.8 1.7 16.4 6.8 342 10 353 165 -6.8 0 -6.6 -7 02/21/2007 10:00:00 10.9 1.7 15.3 6.8 10.4 2 14.9 5.7 10.3 1.8 16.1 5.3 341 11 338 165 -6.7 0 -6.6 -7.2 02/21/2007 10:10:00 11.3 1.2 14.5 7.6 11.2 1.3 14.5 7.6 10.3 1.3 13.3 6.5 337 8 310 165 -6.7 0.1 -6.4 -7.2 02/21/2007 10:20:00 12.5 1.5 15.6 9.1 12.1 1.8 16.1 6.5 11.9 1.7 15.6 8 342 8 343 165 -6.7 0.2 -6.1 -7.4 02/21/2007 10:30:00 13 1.3 15.6 9.1 12.8 1.5 16.1 8 12.8 1.3 16.4 9.1 339 9 343 165 -6.7 0 -6.6 -7 02/21/2007 10:40:00 12.2 1.7 16.8 8 12.1 2.1 17.6 6.1 11.7 1.8 16.4 6.5 339 9 345 165 -7 0.2 -6.6 -7.9 02/21/2007 10:50:00 12.4 1.6 16.1 8.8 12.1 2 16.1 6.8 11.8 1.8 16.8 7.6 342 11 345 165 -6.6 0.2 -6.4 -7.2 02/21/2007 11:00:00 13.3 1.7 17.6 7.6 12.9 2 17.6 6.8 13.1 1.6 17.6 8.8 338 11 346 165 -6.7 0 -6.4 -7 02/21/2007 11:10:00 12.7 1.3 16.4 9.1 11.7 1.7 16.4 6.8 12.5 1.3 15.6 8.4 341 14 360 165 -6.6 0.1 -6.4 -6.8 02/21/2007 11:20:00 12.5 1.7 17.2 8 12 2 17.6 6.1 12 1.8 17.2 8 341 10 343 165 -6.2 0.2 -5.7 -6.8 02/21/2007 11:30:00 12.9 1.2 16.1 9.5 12.8 1.3 16.1 8.8 12.5 1.3 16.1 9.1 336 9 326 165 -6.1 0 -5.9 -6.6 02/21/2007 11:40:00 12.2 1.7 17.2 7.2 11.9 2 17.2 5.7 11.9 1.7 17.2 7.6 338 9 345 165 -6.1 0.2 -5.7 -6.8 02/21/2007 11:50:00 11.3 1.5 15.6 7.6 11.2 1.5 14.9 6.8 11.1 1.5 15.3 7.2 333 10 338 165 -6 0.1 -5.5 -6.4 02/21/2007 12:00:00 9.5 1.7 13.3 6.1 9.3 1.7 13 5.3 9.2 1.7 13.3 5.7 334 10 330 165 -5.5 0 -5.3 -6.1 02/21/2007 12:10:00 10.3 2.3 14.5 5.3 9.8 2.6 14.5 4.6 10.1 2.5 14.9 4.9 341 13 310 165 -5.6 0.2 -5 -6.1 02/21/2007 12:20:00 9.4 1.6 13.3 6.1 8.3 2.2 13.3 3.8 9.3 1.7 13.3 5.3 347 16 333 165 -5.3 0.3 -4.6 -5.7 02/21/2007 12:30:00 11.3 1.7 15.6 6.8 11.1 2 15.6 5.3 11.1 1.9 15.6 6.1 337 11 331 165 -5.6 0.1 -5.3 -5.9 02/21/2007 12:40:00 11.4 1.3 16.4 7.2 11.1 1.7 16.1 4.9 11.4 1.5 17.2 7.6 334 14 323 165 -5.7 0.1 -5.5 -6.1 02/21/2007 12:50:00 11.3 1.2 15.6 7.6 11.4 1.3 14.5 7.2 11.1 1.3 14.1 6.8 334 10 320 165 -5.6 0 -5.3 -5.9 02/21/2007 13:00:00 11.6 1.3 16.1 8 11.6 1.4 15.6 8.4 11.3 1.3 15.3 8 338 9 332 165 -5.6 0 -5.3 -5.9 02/21/2007 13:10:00 11.1 1.2 14.1 7.2 10.6 1.7 14.1 5.3 11 1.2 14.1 7.2 343 9 335 165 -5.3 0 -5 -5.5 02/21/2007 13:20:00 9.4 1.2 13.3 6.1 8.8 1.7 13.3 4.2 9.3 1.3 14.1 6.5 341 12 347 165 -5.2 0.1 -4.8 -5.5 02/21/2007 13:30:00 10.1 1.5 13.3 6.8 9.9 1.5 13.3 5.7 10 1.6 14.1 6.1 338 10 334 165 -5.2 0.1 -4.8 -5.5 02/21/2007 13:40:00 11 1.3 14.5 7.2 10.5 1.7 14.5 6.1 11 1.4 14.9 7.6 344 9 349 165 -5.2 0 -5 -5.5 02/21/2007 13:50:00 8.8 1 11.8 6.5 8.5 1.1 11.8 5.3 8.5 1.2 12.6 6.5 334 14 340 165 -5 0.1 -4.6 -5.5 02/21/2007 14:00:00 8.5 1.3 11.5 4.9 8.4 1.3 11.8 5.3 8 1.5 11.5 4.9 319 18 328 165 -4.9 0 -4.6 -5.3 02/21/2007 14:10:00 9 1.2 11.8 6.1 8.6 1.3 11.8 4.9 8.6 1.3 11.5 5.3 326 18 336 165 -5.1 0.1 -4.6 -5.5 02/21/2007 14:20:00 8.9 1.2 12.2 5.7 8.8 1.2 12.2 5.7 8 1.2 11.5 5.3 309 9 298 165 -5.4 0 -5 -5.7 02/21/2007 14:30:00 8.4 1 11.1 5.7 8.2 1 10.7 6.1 7.9 1.2 10.7 4.6 315 11 312 165 -5.2 0.2 -4.6 -5.7 02/21/2007 14:40:00 9 1.5 13.7 6.1 8.9 1.5 13 5.7 8.2 1.7 13 4.6 316 15 320 165 -5.5 0.1 -5 -5.9 02/21/2007 14:50:00 9.8 1.2 13.7 7.2 9.6 1.2 13.3 6.8 8.8 1.4 13 6.1 310 9 289 165 -5.4 0 -5 -5.7 02/21/2007 15:00:00 9.1 1.2 12.2 6.1 9 1.2 11.8 5.7 8 1.3 11.8 4.6 303 10 296 165 -5.6 0.1 -5.3 -5.9 02/21/2007 15:10:00 8.2 1 11.5 5.7 8.1 1.1 11.5 5.7 7.2 1.2 10.3 4.2 311 10 294 165 -5 0.4 -4.4 -5.9 02/21/2007 15:20:00 9.4 1.3 13 6.5 9.4 1.3 13 6.8 8.6 1.3 11.8 5.3 321 14 313 165 -4.5 0.1 -4.2 -4.8 02/21/2007 15:30:00 9.6 1.7 14.1 5.7 9.6 1.7 14.1 6.1 8.6 2.1 14.1 4.6 318 15 344 165 -4.7 0.2 -4.2 -5 02/21/2007 15:40:00 10.9 1.3 14.9 8.4 10.7 1.4 14.9 6.5 10.1 1.2 13.3 7.2 315 16 286 165 -5.3 0.3 -4.6 -5.7 02/21/2007 15:50:00 11.4 1.7 17.2 7.2 11.3 1.7 17.2 6.8 10.5 1.8 17.2 6.1 314 14 325 165 -5.5 0.2 -5 -5.9 02/21/2007 16:00:00 14.3 1.7 20.2 8.4 14.1 1.7 19.9 8.4 13.3 2.1 19.5 7.6 312 9 315 165 -5.6 0.2 -5 -6.4 02/21/2007 16:10:00 16.6 1.5 22.1 13 16.4 1.4 22.1 13.3 15.3 2.1 22.1 9.9 310 9 305 165 -5.7 0 -5.5 -5.9 02/21/2007 16:20:00 13.7 1.7 21 9.1 13.5 1.7 20.2 9.1 13.2 1.6 17.6 9.9 318 12 316 165 -5.5 0.1 -5.3 -5.7 02/21/2007 16:30:00 13.1 2.1 17.2 5.7 13 2.1 17.6 6.1 12.7 2.2 17.6 6.8 333 12 341 165 -5.3 0 -5 -5.5 02/21/2007 16:40:00 9.2 1.6 13 5.7 8.7 1.7 13.3 4.6 8.3 1.7 12.6 3.8 329 20 297 165 -5 0.1 -4.6 -5.5 02/21/2007 16:50:00 10.9 1.8 17.6 6.5 10.3 2.1 16.4 4.6 10.3 2.2 17.6 4.9 341 14 353 165 -5.2 0.2 -4.8 -5.9 02/21/2007 17:00:00 9.9 1.7 14.5 5.7 9.5 1.7 14.5 5.7 9.7 1.7 13.7 4.6 335 15 336 165 -5.4 0 -5 -5.7 02/21/2007 17:10:00 11.6 2 16.4 5.7 11.5 2 16.1 5.7 11.6 2.2 16.4 4.9 329 11 335 165 -5.8 0.1 -5.5 -6.6 02/21/2007 17:20:00 12.4 1.6 15.6 8 12.2 1.6 15.3 8 12.3 1.7 16.1 8.4 323 11 325 165 -6.1 0 -5.7 -6.6 02/21/2007 17:30:00 9.5 1.3 12.6 5.7 9 1.5 13 4.9 9 1.5 12.6 4.9 337 17 319 165 -6 0 -5.7 -6.6 02/21/2007 17:40:00 11.8 1.2 16.4 8.8 11.5 1.2 14.5 7.6 11.5 1.3 14.9 8 335 9 354 165 -6.3 0.1 -5.9 -6.8 02/21/2007 17:50:00 11.2 2 17.2 6.8 10.8 1.7 15.6 6.1 10.7 2.1 16.8 6.8 336 13 351 165 -6.5 0.1 -6.1 -7.2 02/21/2007 18:00:00 10.2 2.3 15.6 6.1 9.9 2.2 15.6 5.7 9.7 2.5 15.3 5.7 331 15 353 165 -7 0 -6.8 -7.2 02/21/2007 18:10:00 8.1 2 14.5 3.8 7.8 1.8 14.9 3.4 8 2 14.1 3.4 330 16 348 165 -7.2 0 -7 -7.2 02/21/2007 18:20:00 5.7 1.5 9.9 3 5.6 1.5 9.9 3 4.9 1.3 10.3 2.6 314 19 340 165 -7.3 0 -7 -7.4 02/21/2007 18:30:00 6.4 1.3 9.5 3 6.3 1.3 9.5 2.6 5.5 1.3 8.4 2.6 303 15 302 165 -7.4 0.1 -7.2 -7.6 02/21/2007 18:40:00 8.4 1.9 13.3 3.8 8.3 1.9 13.3 3.8 7.8 1.9 12.2 3.8 317 13 336 165 -7.3 0 -7 -7.4 02/21/2007 18:50:00 7 1.4 11.8 4.2 6.8 1.5 12.2 3.4 6.6 1.5 12.6 3.4 331 15 342 165 -7.5 0 -7.2 -7.6 02/21/2007 19:00:00 5.3 1 8.8 2.6 5.2 1 8.4 2.6 4.9 0.9 7.6 3 319 17 289 165 -7.5 0 -7.2 -7.6 02/21/2007 19:10:00 6 1.5 10.3 2.3 5.9 1.5 10.3 3 5.4 1.2 9.9 2.3 314 15 330 165 -7.8 0 -7.4 -8.1 02/21/2007 19:20:00 6 1.2 9.5 3.4 5.9 1.2 9.1 3.4 5.6 1.3 8.8 2.6 320 18 349 165 -7.6 0 -7.4 -8.1 02/21/2007 19:30:00 6.5 1.6 10.3 2.6 6.5 1.6 10.3 2.3 5.7 1.6 10.7 1.1 293 16 273 165 -7.6 0.1 -7.4 -7.9 02/21/2007 19:40:00 5 0.9 7.6 2.3 4.9 0.9 7.6 1.9 4.7 0.8 7.2 2.6 318 16 286 165 -7.8 0 -7.4 -8.1 02/21/2007 19:50:00 4.9 1 7.6 1.9 4.9 1 7.6 2.3 4.4 1 7.2 1.9 300 13 308 165 -7.9 0 -7.6 -8.1 02/21/2007 20:00:00 5.3 0.8 7.2 3.4 5.2 0.7 7.2 3 5 0.9 7.6 3 319 17 310 165 -8 0 -7.6 -8.1 02/21/2007 20:10:00 8.5 1.3 11.1 5.3 8.4 1.3 11.1 5.3 8.5 1.3 11.5 5.3 333 10 350 165 -8 0 -7.6 -8.3 02/21/2007 20:20:00 10.6 1.5 15.3 6.8 10.4 1.5 15.3 6.5 10.4 1.4 14.9 6.8 326 9 339 165 -8 0 -7.9 -8.3 02/21/2007 20:30:00 10.3 2.3 16.4 4.9 9.9 2.4 16.1 3.8 10.2 2.3 16.4 4.2 338 14 341 165 -8 0 -7.9 -8.1 02/21/2007 20:40:00 10.4 1.7 15.6 4.2 9.2 2 15.3 4.6 10 1.8 15.3 4.2 348 17 360 165 -7.8 0.1 -7.4 -8.1 02/21/2007 20:50:00 7.7 2.5 13 0.4 7 2.6 13 0.4 7.3 2.6 14.1 0.4 341 29 328 165 -7.5 0.1 -7.2 -7.9 02/21/2007 21:00:00 5.8 1.7 11.1 1.5 5.1 1.6 9.9 0.7 5.1 1.5 10.3 1.9 4 29 1 165 -7.7 0 -7.4 -8.1 02/21/2007 21:10:00 5.6 1.2 8.4 2.6 5 1.4 8.8 1.5 5.6 1.3 9.1 2.6 6 21 344 165 -7.8 0 -7.6 -8.1 02/21/2007 21:20:00 5 1.3 9.1 2.6 4.3 1.3 8.8 1.9 5.3 1.3 9.1 2.6 348 19 4 165 -7.8 0.1 -7.4 -8.1 02/21/2007 21:30:00 5.7 1.2 9.1 2.6 5.6 1.4 8.8 1.9 5.6 1.2 8.8 3 338 10 338 165 -8 0 -7.6 -8.3 02/21/2007 21:40:00 6.1 1.1 9.1 4.2 6 1.1 9.1 3.4 5.5 1 8.8 3 313 20 295 165 -8.1 0 -8.1 -8.5 02/21/2007 21:50:00 8.1 1 11.5 5.7 8.1 1 11.1 5.7 6.6 1.2 10.3 4.2 294 8 283 165 -8.1 0 -8.1 -8.5 02/21/2007 22:00:00 9.5 1.3 12.2 6.1 9.4 1.2 12.6 5.7 7.8 1.3 11.8 4.9 291 8 292 165 -8 0 -7.9 -8.1 02/21/2007 22:10:00 9.7 1.3 13.3 6.8 9.7 1.2 13.3 6.8 8.2 1.7 13.7 4.9 289 10 290 165 -7.9 0.2 -7.4 -8.1 02/21/2007 22:20:00 8.4 1.3 12.2 4.9 8.3 1.3 11.8 4.9 7.3 1.4 10.7 3.8 295 12 302 165 -8 0.1 -7.6 -8.3 02/21/2007 22:30:00 9.2 0.9 11.5 7.2 9.1 0.9 11.5 7.2 7.7 1.1 10.3 5.3 302 9 306 165 -7.9 0 -7.6 -8.1 02/21/2007 22:40:00 10.1 1.5 13 6.1 10 1.4 12.6 6.1 8.8 1.3 11.8 5.7 307 8 302 165 -8 0.1 -7.6 -8.3 02/21/2007 22:50:00 7.7 1.5 13 3.4 7.4 1.6 12.6 3.4 7.4 1.7 12.6 3 330 14 323 165 -8.1 0.2 -7.6 -8.5 02/21/2007 23:00:00 7.2 1.7 11.8 3.4 7.1 1.6 11.8 3.4 6.8 1.5 11.8 3.4 314 24 276 165 -7.6 0.1 -7.2 -8.1 02/21/2007 23:10:00 8.2 1.3 11.5 4.9 8.2 1.2 11.1 4.6 7.3 1.5 11.5 3.4 287 11 286 165 -8 0.1 -7.6 -8.3 02/21/2007 23:20:00 10.2 1.6 14.1 6.1 10.2 1.6 13.7 4.9 9.7 2 14.1 5.7 287 12 283 165 -7.9 0.1 -7.6 -8.1 02/21/2007 23:30:00 11.2 1.4 14.9 7.2 11.1 1.3 14.1 6.8 9.7 1.3 13.3 5.7 306 17 307 165 -8.2 0.1 -7.9 -8.5 02/21/2007 23:40:00 8.5 1.2 11.1 4.6 8.4 1.2 11.1 4.9 8 1.2 11.1 4.6 315 13 305 165 -8.2 0 -7.9 -8.3 02/21/2007 23:50:00 10.5 1.3 14.1 7.2 10.4 1.3 13.7 7.2 9.3 1.9 15.3 3.4 293 12 288 165 -8.1 0.2 -7.6 -8.3 02/22/2007 00:00:00 10.5 1.3 14.1 6.8 10.4 1.2 14.1 7.2 9.8 1 12.6 7.2 314 14 301 165 -8.1 0.1 -7.6 -8.5 02/22/2007 00:10:00 11.1 1 13.3 8.8 11 0.9 13.3 8.8 9.3 1.2 12.2 6.8 305 9 291 165 -8.3 0 -8.1 -8.5 02/22/2007 00:20:00 10.8 1.1 13.7 7.6 10.7 1.1 13.7 8 9.2 1.2 13.7 6.5 307 7 296 165 -8.3 0 -8.1 -8.5 02/22/2007 00:30:00 10.6 1.2 14.1 7.6 10.5 1.2 14.1 7.2 8.6 1.3 13 5.7 302 9 289 165 -8.3 0.2 -7.9 -8.5 02/22/2007 00:40:00 11.2 1.2 15.6 8 11.1 1.1 14.9 8 9.1 1.3 13.3 6.1 302 9 299 165 -8.1 0 -7.6 -8.3 02/22/2007 00:50:00 11.5 1.4 14.1 7.2 11.3 1.3 13.7 7.2 9.8 1.1 13 7.2 307 8 305 165 -8.2 0 -8.1 -8.5 02/22/2007 01:00:00 10 1.5 13.3 5.7 9.9 1.4 13 5.7 8.3 1.3 11.1 4.9 302 9 285 165 -8.2 0.1 -7.9 -8.5 02/22/2007 01:10:00 9.3 1.3 12.6 5.7 9.2 1.3 12.6 5.7 7.9 1.1 10.7 5.3 304 12 295 165 -8.4 0.1 -8.1 -8.5 02/22/2007 01:20:00 9.1 1.3 13 5.3 9 1.3 12.2 4.9 7.8 1.1 11.8 5.3 304 11 290 165 -8.4 0 -8.3 -8.7 02/22/2007 01:30:00 8.6 1.2 12.2 6.1 8.6 1.1 12.2 6.1 7.1 1.2 11.5 3.8 298 11 290 165 -8.2 0 -8.1 -8.5 02/22/2007 01:40:00 8.3 1.7 12.6 4.9 8.2 1.6 12.2 4.9 7.2 1.3 10.7 3.8 307 13 275 165 -8.4 0.1 -8.1 -8.7 02/22/2007 01:50:00 10.1 1.3 13.7 6.1 10 1.2 13.7 6.1 8.4 1.4 13.7 5.3 301 11 314 165 -8.3 0 -8.1 -8.5 02/22/2007 02:00:00 10.6 1.2 14.1 6.5 10.5 1.2 14.9 6.1 8.9 1.6 14.1 6.1 305 13 315 165 -8.2 0 -8.1 -8.5 02/22/2007 02:10:00 10.2 1.1 13.3 7.6 10.1 1 13.3 8 8.4 1.1 11.1 5.3 301 9 304 165 -8.4 0.1 -8.1 -8.5 02/22/2007 02:20:00 8.1 1 11.5 4.6 8 1 11.5 4.6 7.1 1.1 9.9 4.2 307 9 296 165 -8.5 0 -8.3 -8.7 02/22/2007 02:30:00 9 1.2 13 5.7 9 1.1 12.6 6.1 7.6 1.4 12.2 4.9 302 12 287 165 -8.5 0 -8.3 -8.7 02/22/2007 02:40:00 7.6 1 9.5 5.3 7.5 1 9.5 5.3 6.6 1.1 9.5 4.6 307 8 307 165 -8.4 0.1 -8.1 -8.7 02/22/2007 02:50:00 7.2 1.2 10.3 3.4 7.1 1.2 10.3 3.4 6.6 1.2 10.3 3.4 313 12 300 165 -8.7 0 -8.3 -8.9 02/22/2007 03:00:00 7.1 1.1 10.3 3.8 7 1.1 9.9 4.2 6 1 8.4 3.8 306 11 299 165 -8.4 0.1 -8.1 -8.7 02/22/2007 03:10:00 6.3 0.9 8.4 3.4 6.2 1 8.4 2.3 5.8 0.9 7.6 3.8 321 17 297 165 -8.8 0 -8.5 -8.9 02/22/2007 03:20:00 7.4 0.7 9.5 5.7 7.3 0.7 9.1 5.7 7 0.7 9.1 5.3 315 10 306 165 -8.6 0 -8.5 -8.9 02/22/2007 03:30:00 8 1 10.7 5.3 7.9 0.9 10.7 5.3 6.4 1 8.8 4.2 299 9 303 165 -8.7 0 -8.3 -8.9 02/22/2007 03:40:00 7.4 1 10.3 4.6 7.3 1.1 10.3 4.2 6 1 8.8 3 304 9 285 165 -8.4 0.1 -8.1 -8.7 02/22/2007 03:50:00 6.2 0.7 8 4.6 6 0.6 7.6 4.2 5.4 0.7 7.2 3.4 307 13 310 165 -8.7 0 -8.5 -8.9 02/22/2007 04:00:00 6.6 0.8 8.8 4.2 6.5 0.8 8.8 3.8 5.4 0.9 8.4 3.4 302 11 303 165 -8.4 0.1 -8.3 -8.9 02/22/2007 04:10:00 6 1 8.4 3.8 5.8 1 8.4 3.4 5.4 1 8.4 3 318 18 331 165 -8.4 0.1 -8.1 -8.5 02/22/2007 04:20:00 6.8 1 9.5 4.6 6.7 1 9.5 4.6 6.2 1.2 9.9 3 311 15 279 165 -8.5 0 -8.3 -8.7 02/22/2007 04:30:00 7.6 1.3 12.6 4.2 7.5 1.3 11.8 2.3 7.2 1.4 12.2 4.2 317 13 333 165 -8.3 0 -8.1 -8.5 02/22/2007 04:40:00 6.1 1.1 9.1 3 6 1.1 9.1 3 5.7 1.2 9.5 3.4 318 13 349 165 -8.2 0 -8.1 -8.5 02/22/2007 04:50:00 5.3 1.1 8 3 5.3 1 8 3 4.9 0.9 7.6 3 315 13 339 165 -8.3 0 -8.1 -8.5 02/22/2007 05:00:00 6 1 8.4 3.4 5.8 1.1 8.4 3.4 5.7 1.1 8.8 3 326 18 305 165 -8.4 0 -8.1 -8.7 02/22/2007 05:10:00 5.7 1.1 8.8 2.6 5.6 1.1 9.1 3 5 1 8 2.3 309 15 313 165 -8.4 0 -8.1 -8.5 02/22/2007 05:20:00 5.6 1 8 3 5.5 1 8 2.6 5.2 1 8 3 311 15 330 165 -8.4 0.1 -8.1 -8.5 02/22/2007 05:30:00 5.9 0.9 8 2.6 5.6 1.1 8 2.3 5.5 0.9 7.6 3.4 328 20 336 165 -8.4 0 -8.1 -8.7 02/22/2007 05:40:00 6.3 1.5 10.3 1.5 5.8 1.8 10.7 1.1 6.3 1.6 11.1 1.5 335 21 330 165 -8.2 0.1 -7.9 -8.5 02/22/2007 05:50:00 6.1 1.1 8.8 3.4 5.6 1.3 8.8 2.3 5.9 1.3 9.1 1.1 339 17 355 165 -8.1 0 -7.9 -8.3 02/22/2007 06:00:00 7.4 1.8 11.5 2.3 7 1.9 11.5 2.6 7.4 1.9 11.8 3 341 14 344 165 -8.1 0 -8.1 -8.3 02/22/2007 06:10:00 5.8 1.3 8.8 1.9 5.5 1.5 8.4 1.5 5.5 1.3 8.8 2.3 331 17 331 165 -8.2 0 -8.1 -8.5 02/22/2007 06:20:00 5.5 0.8 7.6 4.2 5.4 0.8 7.6 2.6 5.2 0.8 7.6 3.4 319 17 309 165 -8.2 0 -8.1 -8.5 02/22/2007 06:30:00 6 1.3 9.5 3.4 5.9 1.3 9.1 3 5.7 1.2 9.1 2.6 318 15 332 165 -8.2 0 -8.1 -8.5 02/22/2007 06:40:00 5.5 1.2 8.8 3 5.4 1.2 9.1 2.6 4.9 1.4 9.5 1.9 312 13 344 165 -8.4 0.1 -8.1 -8.7 02/22/2007 06:50:00 6.4 1.3 9.9 3.4 6.3 1.3 9.9 3.4 6.5 1.2 9.9 3.8 332 10 332 165 -8.3 0 -8.1 -8.5 02/22/2007 07:00:00 5.8 1.3 9.5 3 5.7 1.3 10.3 3 5.7 1.5 9.5 2.6 331 16 344 165 -8.3 0 -8.1 -8.5 02/22/2007 07:10:00 5.5 1.1 8.4 3 5.2 1.1 8.4 3 5.4 1.1 8.4 3.4 330 17 345 165 -8.2 0 -8.1 -8.5 02/22/2007 07:20:00 6.3 1.7 9.9 3 6.2 1.8 9.9 2.3 6.1 1.5 9.5 2.6 333 16 336 165 -8.4 0 -8.3 -8.5 02/22/2007 07:30:00 6.1 1.4 11.1 3 5.9 1.3 9.9 3 5.9 1.4 9.9 3.4 327 13 351 165 -8.2 0 -8.1 -8.5 02/22/2007 07:40:00 6.2 1.4 9.1 3.4 5.9 1.3 9.1 3.4 6.1 1.3 8.8 3.4 330 16 354 165 -8.2 0 -8.1 -8.5 02/22/2007 07:50:00 5.4 1.1 7.6 2.6 5.1 1.1 8 1.9 5.1 1.2 7.6 1.5 331 17 350 165 -8.3 0 -8.1 -8.5 02/22/2007 08:00:00 5.4 1.4 9.1 2.6 5.1 1.3 9.5 1.9 5.3 1.4 9.1 2.3 331 16 328 165 -8.3 0 -8.1 -8.5 02/22/2007 08:10:00 5.1 1.2 8 2.6 5.1 1.2 8 3 4.5 1.3 7.6 1.5 306 17 316 165 -8.3 0 -8.1 -8.5 02/22/2007 08:20:00 4.6 1.3 7.6 1.9 4.6 1.2 7.6 1.5 4.2 1.2 8.4 1.9 302 14 302 165 -8.4 0.1 -8.1 -8.5 02/22/2007 08:30:00 6.1 1 10.3 4.2 6 1 9.9 4.2 5.4 0.9 8.8 3.4 308 13 286 165 -8.4 0.1 -8.1 -8.7 02/22/2007 08:40:00 6.4 0.9 8.4 3.8 6.3 0.9 8 4.2 5 0.9 7.6 3 298 7 290 165 -8.4 0 -8.1 -8.5 02/22/2007 08:50:00 6.7 0.8 8.8 3.8 6.6 0.8 8.8 3.8 5.4 0.9 8 3.4 303 8 303 165 -8.4 0 -8.1 -8.7 02/22/2007 09:00:00 7 0.8 8.8 4.6 7 0.7 8.8 4.6 5.8 1.1 8.8 3.8 301 9 286 165 -8.2 0 -8.1 -8.5 02/22/2007 09:10:00 6.6 1 8.8 4.2 6.5 1 8.4 4.2 5.7 1 8.8 3.4 303 11 292 165 -7.9 0.3 -7.4 -8.5 02/22/2007 09:20:00 6.1 1.1 8.8 2.6 6.1 1 8.4 3 5.2 1 7.6 3 301 12 299 165 -7.4 0.1 -7.2 -7.6 02/22/2007 09:30:00 6.2 0.9 8.8 4.2 6.1 0.9 8.4 4.2 5 1 7.6 3 299 8 300 165 -7.3 0.1 -6.8 -7.6 02/22/2007 09:40:00 6.6 0.8 9.5 3.8 6.5 0.8 9.1 3.8 6.1 0.9 8.4 3.8 310 9 307 165 -7.1 0.1 -6.8 -7.4 02/22/2007 09:50:00 5.7 0.7 7.6 4.2 5.6 0.7 7.2 4.2 5.3 0.8 7.6 3.4 311 9 281 165 -6.9 0.1 -6.6 -7.2 02/22/2007 10:00:00 5.2 1 8 3 5.2 1 8 2.6 4.7 0.8 7.6 2.6 318 17 310 165 -6.5 0.2 -6.1 -7 02/22/2007 10:10:00 6 1 8.8 3.4 5.9 1 8.8 3.4 5.4 1.1 10.7 2.3 307 13 288 165 -6.7 0.3 -6.1 -7.4 02/22/2007 10:20:00 6 0.9 8.4 3.8 5.9 0.9 8.4 3.4 5.2 0.8 8.4 3 308 12 283 165 -7 0.2 -6.4 -7.4 02/22/2007 10:30:00 5.2 0.9 7.6 2.3 5.1 0.8 7.6 2.3 4.8 0.8 7.2 1.9 312 19 306 165 -7.2 0.1 -6.8 -7.6 02/22/2007 10:40:00 4.9 0.9 7.2 2.3 4.8 0.9 6.8 2.6 4.8 0.9 7.2 3 323 11 316 165 -6.4 0.2 -5.7 -7 02/22/2007 10:50:00 6.2 1.1 9.5 3.4 6.1 1.1 9.1 3.4 5.8 1.2 8.8 3 319 14 328 165 -6.4 0.1 -6.1 -6.8 02/22/2007 11:00:00 5.3 1 7.2 2.6 5.2 1 7.6 2.6 5.2 0.9 7.6 3 328 15 356 165 -5.8 0.2 -5.3 -6.6 02/22/2007 11:10:00 5.6 1 8 3 5.5 0.9 8 3 5 1 7.6 2.6 309 15 314 165 -5.8 0.2 -5.5 -6.6 02/22/2007 11:20:00 6.1 1 8.4 3.4 6 1 8.4 3.8 5.1 1.1 8 3 302 10 296 165 -6.4 0.1 -5.9 -6.8 02/22/2007 11:30:00 6.3 1.1 8.8 3.8 6.2 1.1 9.1 3.8 5.3 1 8 2.6 304 10 304 165 -6.2 0.3 -5.5 -6.8 02/22/2007 11:40:00 5.8 1.3 8.8 2.6 5.7 1.2 8.8 2.6 5 1.1 8 2.6 304 12 290 165 -6.2 0.2 -5.7 -6.6 02/22/2007 11:50:00 5.4 0.9 8 2.3 5.4 0.9 7.6 1.9 4.5 0.8 6.8 2.6 300 9 300 165 -6.1 0 -5.7 -6.4 02/22/2007 12:00:00 5.6 0.6 7.2 3.8 5.6 0.6 7.2 3.8 4.8 0.9 8 2.6 299 9 293 165 -6.2 0.2 -5.7 -6.6 02/22/2007 12:10:00 6.8 0.9 9.1 4.9 6.7 0.9 8.8 4.9 5.8 0.8 8.4 3.8 300 10 293 165 -6 0.1 -5.7 -6.6 02/22/2007 12:20:00 6.2 1.2 9.1 3 6.1 1.1 8.8 3 5.4 1.3 8.8 1.9 306 10 309 165 -5.8 0.3 -5 -6.6 02/22/2007 12:30:00 5.9 0.7 8 4.2 5.9 0.7 8 3.8 4.9 0.6 6.8 3 304 8 296 165 -5.3 0.1 -5 -5.7 02/22/2007 12:40:00 6.6 1 8.8 3.8 6.5 1 9.1 3.8 6.2 1 8.8 3.8 315 13 290 165 -5.6 0.1 -5.5 -5.9 02/22/2007 12:50:00 6.6 0.9 9.1 4.9 6.5 0.9 9.1 4.6 6 0.9 8.8 4.2 310 11 289 165 -5.4 0 -5 -5.7 02/22/2007 13:00:00 6.8 0.9 9.1 4.2 6.7 0.9 8.8 4.6 6.4 0.8 8.4 4.2 320 12 313 165 -5.1 0.1 -4.6 -5.5 02/22/2007 13:10:00 5.4 0.8 7.2 3 5.3 0.8 7.2 3 4.7 0.8 7.2 3 314 14 319 165 -4.9 0 -4.6 -5 02/22/2007 13:20:00 5.8 0.9 8.8 3.8 5.7 0.9 8.4 3.4 5.1 0.9 7.2 3.4 309 10 293 165 -4.7 0.2 -4.2 -5 02/22/2007 13:30:00 6.7 1.1 10.3 3.4 6.6 1.1 10.3 3.4 6.1 1.1 9.1 3.4 315 12 331 165 -4.8 0.2 -4.4 -5.3 02/22/2007 13:40:00 6.8 1.1 9.5 4.6 6.7 1 9.5 4.6 6 1.2 9.5 3.4 312 12 310 165 -4.8 0.1 -4.4 -5.3 02/22/2007 13:50:00 6.4 0.6 8 4.6 6.3 0.6 8 4.9 5.8 0.8 8 3.8 313 10 318 165 -4.5 0.2 -4.2 -5 02/22/2007 14:00:00 6.4 1.1 9.9 3.8 6.3 1.1 9.9 3.8 5.8 1.1 9.5 3.8 313 15 339 165 -4.8 0.1 -4.4 -5 02/22/2007 14:10:00 7.5 0.7 10.7 6.1 7.4 0.7 9.9 6.1 6.9 0.9 8.8 4.6 310 7 294 165 -5 0.1 -4.6 -5.3 02/22/2007 14:20:00 8.2 1 10.3 4.9 8.2 1 10.3 5.3 6.9 0.9 9.5 4.9 303 9 296 165 -5.2 0.2 -4.6 -5.5 02/22/2007 14:30:00 7.8 1 11.5 5.3 7.7 0.9 10.7 5.3 7.1 1 10.3 4.9 312 8 312 165 -4.7 0.1 -4.4 -5 02/22/2007 14:40:00 7.5 0.9 10.7 5.3 7.5 0.9 10.3 5.3 6.3 0.9 9.5 4.2 306 7 299 165 -4.9 0.1 -4.4 -5.3 02/22/2007 14:50:00 7.5 1 9.5 3.4 7.4 1 9.1 4.2 6.4 1.1 8.8 3.4 304 13 287 165 -4.8 0 -4.4 -5 02/22/2007 15:00:00 7.4 1 9.9 5.3 7.3 1 9.9 5.3 6.7 1.2 10.3 4.2 312 13 293 165 -4.7 0.1 -4.4 -5 02/22/2007 15:10:00 6.4 0.8 8 3.4 6.3 0.8 7.6 3.4 5.9 0.9 8.4 3.4 315 9 322 165 -4.3 0 -4.2 -4.6 02/22/2007 15:20:00 6.1 0.8 8.4 3.8 6 0.8 8.4 3.4 5.8 1 8.8 3.8 322 13 340 165 -4.1 0.1 -3.7 -4.4 02/22/2007 15:30:00 5.7 0.7 7.2 3.8 5.6 0.7 7.6 3.8 5.2 0.8 6.8 3 315 15 306 165 -4.2 0.1 -3.7 -4.4 02/22/2007 15:40:00 6 0.6 7.6 4.2 6 0.6 7.6 3.8 4.9 0.8 7.2 2.6 302 8 297 165 -4.7 0.1 -4.4 -5 02/22/2007 15:50:00 5.7 1 8.8 3.8 5.7 1 8.8 3.4 4.8 1 7.6 2.6 301 10 300 165 -4.8 0.1 -4.4 -5 02/22/2007 16:00:00 5.9 1 9.5 3.8 5.9 0.9 9.5 3.8 5.4 1.1 8.4 3.4 303 13 285 165 -4.6 0.1 -4.2 -5 02/22/2007 16:10:00 5.2 0.5 6.5 3.4 5.1 0.5 6.5 3 4.6 0.6 6.1 3 312 9 326 165 -4.2 0.2 -3.9 -4.6 02/22/2007 16:20:00 4.7 0.8 6.8 2.6 4.5 0.8 6.1 2.6 4.3 0.9 6.5 1.9 327 19 354 165 -3.8 0 -3.5 -4.2 02/22/2007 16:30:00 4.3 0.7 6.8 2.6 4.2 0.7 6.8 2.6 4 0.7 6.5 2.3 319 12 309 165 -4.2 0.2 -3.5 -4.6 02/22/2007 16:40:00 3.9 0.7 6.1 2.3 3.9 0.6 5.7 2.3 3.4 0.7 4.9 1.9 313 12 312 165 -3.7 0.2 -3.3 -4.4 02/22/2007 16:50:00 4.5 0.7 6.1 2.3 4.4 0.8 6.5 2.6 4.1 0.7 6.1 2.3 322 15 309 165 -4.3 0.1 -3.9 -4.6 02/22/2007 17:00:00 4.2 0.7 6.1 2.6 4.1 0.7 6.1 1.9 3.8 0.5 5.7 2.3 322 12 333 165 -4.2 0 -3.9 -4.4 02/22/2007 17:10:00 4.5 0.5 6.5 3.4 4.4 0.6 6.5 2.3 4.4 0.4 6.1 3 335 9 343 165 -4.4 0.2 -4.2 -5 02/22/2007 17:20:00 5.1 0.6 6.8 3.4 5.1 0.7 6.8 3 5 0.5 6.5 3.8 342 8 349 165 -4.9 0.1 -4.6 -5.7 02/22/2007 17:30:00 6.3 0.8 8.4 3.8 6.3 0.9 8.8 3.4 6 0.8 8 3.8 339 8 344 165 -5.2 0.1 -4.8 -5.5 02/22/2007 17:40:00 5.8 0.7 7.6 3.8 5.8 0.7 7.6 3.8 5.8 0.8 7.6 3.8 332 7 338 165 -5.7 0.1 -5.3 -6.1 02/22/2007 17:50:00 5.4 1.1 9.1 3 5.3 1.2 9.1 3 5.4 1.2 9.5 3.4 337 10 344 165 -5.8 0.1 -5.5 -6.4 02/22/2007 18:00:00 5.4 0.9 7.2 3.8 4.9 0.9 6.8 2.3 5.3 0.8 7.6 3.8 341 13 337 165 -6.4 0.2 -5.7 -6.8 02/22/2007 18:10:00 5.4 0.8 7.2 3.4 5.4 0.9 7.6 3.4 5.2 0.8 7.2 3.8 330 15 338 165 -6.9 0 -6.6 -7 02/22/2007 18:20:00 5.6 0.7 7.6 4.2 5.5 0.6 7.2 4.2 5.1 0.8 6.8 3.4 320 11 343 165 -7.1 0.1 -6.6 -7.4 02/22/2007 18:30:00 5.4 0.6 7.6 3.8 5.3 0.6 7.2 3 5.3 0.6 6.8 3.8 334 8 332 165 -7.2 0 -6.8 -7.4 02/22/2007 18:40:00 5.2 0.6 6.8 3.4 5.1 0.6 6.5 3 5 0.8 6.8 3.4 324 13 322 165 -7.2 0 -6.8 -7.4 02/22/2007 18:50:00 5.8 0.6 7.6 3.8 5.7 0.7 7.6 3.4 5.7 0.6 7.2 4.2 342 8 356 165 -7.2 0 -6.8 -7.4 02/22/2007 19:00:00 5.3 0.6 6.8 3.4 5.2 0.7 7.2 3 5.3 0.6 6.8 3.4 340 10 351 165 -7.3 0 -7.2 -7.4 02/22/2007 19:10:00 4.6 0.4 6.5 3.4 4.5 0.4 5.7 3.4 4.6 0.5 5.7 2.6 330 9 312 165 -7.3 0 -7 -7.6 02/22/2007 19:20:00 3.7 0.6 5.7 2.3 3.6 0.6 5.7 2.3 3.8 0.5 4.9 2.6 327 9 327 165 -7.3 0.1 -6.8 -7.4 02/22/2007 19:30:00 5.3 0.9 7.6 3 5.2 0.9 7.6 3 5.2 1 7.6 3 336 8 336 165 -7.5 0 -7.2 -7.6 02/22/2007 19:40:00 6.3 1 9.9 4.6 5.9 1.2 9.5 3 6.2 0.9 9.5 4.6 343 11 330 165 -7.4 0.1 -7.2 -7.6 02/22/2007 19:50:00 6.2 0.8 8.8 4.2 6 1 8 2.6 6 0.8 8 3.8 338 9 348 165 -7.6 0 -7.4 -7.9 02/22/2007 20:00:00 6.3 1.1 8.8 3.8 5.3 1.7 9.1 2.3 6.4 1.2 9.1 3.8 347 13 346 165 -7.5 0 -7.2 -7.6 02/22/2007 20:10:00 6.9 0.9 8.8 4.6 6.8 1 9.1 4.6 6.9 0.9 9.1 4.9 338 8 328 165 -7.4 0 -7.2 -7.6 02/22/2007 20:20:00 7.1 1.2 9.9 4.2 7 1.3 9.9 3 7.2 1.2 10.7 3.8 336 8 342 165 -7.5 0 -7.2 -7.6 02/22/2007 20:30:00 6.3 1 9.5 4.6 5.6 1.3 9.1 2.6 6.2 1 9.1 3.8 344 13 311 165 -7.5 0 -7.2 -7.6 02/22/2007 20:40:00 7 1.1 9.5 4.6 6.8 1.1 9.5 4.6 6.9 1 9.9 4.6 337 9 350 165 -7.5 0.1 -7.4 -7.6 02/22/2007 20:50:00 6.7 0.8 8.8 4.9 6.5 1 9.1 3.4 6.8 0.7 9.1 4.9 337 12 315 165 -7.5 0 -7.2 -7.6 02/22/2007 21:00:00 6.8 1.3 10.7 4.6 6.4 1.3 11.1 3 6.8 1.1 10.7 4.9 335 11 354 165 -7.5 0 -7.2 -7.6 02/22/2007 21:10:00 6.9 1.3 10.3 4.6 6.8 1.4 10.7 3.8 6.8 1.3 9.5 4.2 331 10 341 165 -7.6 0 -7.4 -7.9 02/22/2007 21:20:00 6.3 1 8.8 3.4 6.1 1 8.8 2.3 6.1 1.1 8.8 2.6 332 12 336 165 -7.8 0.1 -7.4 -8.1 02/22/2007 21:30:00 5.5 1.1 8 3.4 5.3 1.1 8.4 3.4 5.3 1.2 8 3 335 7 341 165 -7.9 0.1 -7.4 -8.1 02/22/2007 21:40:00 4.3 1.2 7.6 1.5 3.9 1.3 7.6 1.5 4.2 1.2 7.2 1.5 337 15 334 165 -7.8 0.1 -7.6 -8.1 02/22/2007 21:50:00 3.9 0.9 6.8 2.3 3.7 1 6.8 1.1 3.6 0.8 6.1 1.9 328 17 320 165 -8.1 0.1 -7.6 -8.3 02/22/2007 22:00:00 3.7 0.9 5.7 2.3 3.6 0.9 5.7 2.3 3.6 0.9 5.7 1.9 323 7 328 165 -8 0.1 -7.6 -8.3 02/22/2007 22:10:00 3.8 0.7 6.1 2.3 3.6 0.8 5.7 1.5 3.5 0.8 5.7 1.9 333 21 347 165 -8.3 0.1 -8.1 -8.5 02/22/2007 22:20:00 3.3 0.9 5.7 1.5 3.2 1 5.7 0.7 3 0.8 5.3 0.4 321 20 303 165 -8.2 0 -8.1 -8.5 02/22/2007 22:30:00 3 1.1 5.7 0.4 2.7 1.2 5.7 0.4 2.9 1 5.3 1.5 339 17 313 165 -8.4 0.1 -8.1 -8.7 02/22/2007 22:40:00 4.6 0.9 7.6 2.6 4.4 1 7.6 1.9 4.4 1 7.6 1.9 329 14 330 165 -8.2 0.2 -7.9 -8.7 02/22/2007 22:50:00 4 1 7.2 1.9 3.8 1 7.2 1.9 3.9 0.9 7.6 2.3 330 11 334 165 -8 0.1 -7.6 -8.3 02/22/2007 23:00:00 5 1 7.6 3 4.8 1 7.6 1.9 5 1.1 8 3 330 12 340 165 -8.1 0.1 -7.9 -8.3 02/22/2007 23:10:00 4.5 0.8 6.8 2.6 4.4 0.7 6.8 2.6 4.5 0.8 6.8 3 326 10 334 165 -8 0.1 -7.6 -8.1 02/22/2007 23:20:00 4.6 0.7 7.2 3 4.3 0.7 6.5 2.6 4.5 0.8 6.8 2.6 334 15 347 165 -8.1 0 -8.1 -8.3 02/22/2007 23:30:00 3.5 0.7 5.3 1.9 3.4 0.7 4.9 1.5 3.5 0.5 4.9 2.3 324 13 328 165 -8.1 0 -7.9 -8.3 02/22/2007 23:40:00 4.1 0.8 6.1 1.9 3.9 0.8 6.1 1.9 4.1 0.7 5.7 2.3 329 15 359 165 -8.2 0.2 -7.6 -8.5 02/22/2007 23:50:00 5.7 1 8 3 5.5 1 7.6 3 5.6 1 7.6 3.4 330 15 334 165 -7.9 0 -7.6 -8.1 02/23/2007 00:00:00 6.8 1 9.5 4.6 6.7 1.1 9.9 3.8 6.8 1.1 10.7 4.6 331 11 339 165 -7.8 0 -7.6 -8.1 02/23/2007 00:10:00 6.4 1.2 9.9 4.2 6.3 1.2 10.3 3 6.4 1.2 9.9 3.8 329 14 344 165 -7.8 0 -7.6 -8.1 02/23/2007 00:20:00 7.2 1.2 10.3 4.6 7.1 1.2 10.3 3.4 7.2 1.2 10.3 4.6 329 10 338 165 -7.6 0 -7.4 -7.9 02/23/2007 00:30:00 5.5 1.1 8 2.3 5.2 1.3 8 1.9 5.3 1.4 8.4 2.3 328 23 328 165 -7.8 0 -7.6 -8.1 02/23/2007 00:40:00 7.3 1.5 11.8 3.8 7.2 1.5 11.5 3.8 7.1 1.6 11.8 3.8 328 12 333 165 -7.8 0 -7.6 -8.1 02/23/2007 00:50:00 7.5 1.8 11.8 3.8 7.3 1.9 11.8 3 7.3 1.7 11.1 4.2 335 13 338 165 -7.6 0 -7.4 -7.9 02/23/2007 01:00:00 7.7 1 10.7 5.7 7.5 1.1 10.3 4.2 7.7 1.2 11.1 4.9 331 12 338 165 -7.6 0 -7.4 -7.6 02/23/2007 01:10:00 7.3 2 12.2 4.2 7.2 1.9 12.2 3.8 7.1 2 11.8 3.4 328 15 333 165 -7.6 0 -7.4 -7.9 02/23/2007 01:20:00 8.3 2.3 14.5 4.2 8.1 2.4 14.9 4.2 8.3 2.4 14.5 3.4 331 16 322 165 -7.6 0 -7.4 -7.9 02/23/2007 01:30:00 6 1.2 9.1 3.4 5.8 1.2 9.1 3 5.7 1.2 8.8 3 328 13 318 165 -7.6 0 -7.4 -7.9 02/23/2007 01:40:00 3.9 0.8 5.7 2.3 3.8 0.8 5.7 2.3 3.9 0.7 5.7 2.3 325 15 311 165 -7.8 0 -7.6 -8.1 02/23/2007 01:50:00 4.7 0.8 6.5 2.3 4.5 0.9 6.5 2.6 4.6 0.9 6.8 2.3 328 14 321 165 -7.9 0 -7.6 -8.1 02/23/2007 02:00:00 5.2 1 8.8 3 5 0.9 8.4 2.6 5.2 1 8.4 3 325 18 3 165 -7.8 0 -7.6 -8.1 02/23/2007 02:10:00 5.2 1.4 9.1 2.3 5.1 1.4 8.8 2.3 4.9 1.3 8.4 2.3 322 16 320 165 -7.8 0 -7.6 -8.1 02/23/2007 02:20:00 7.1 2.8 13 3 6.9 2.8 13 2.3 6.9 2.8 12.6 2.6 330 17 325 165 -7.9 0.1 -7.6 -8.1 02/23/2007 02:30:00 8.7 1.2 13 5.7 8.5 1.2 13 5.3 8.9 1.2 12.2 6.1 331 13 316 165 -7.6 0 -7.4 -7.6 02/23/2007 02:40:00 7.5 1.2 11.1 4.6 7.2 1.3 10.7 3.4 7.5 1.2 11.5 5.3 338 11 323 165 -7.5 0 -7.4 -7.6 02/23/2007 02:50:00 6.7 1.5 10.7 3.8 6.5 1.5 10.7 3 6.5 1.5 10.7 3.8 329 13 323 165 -7.7 0 -7.4 -7.9 02/23/2007 03:00:00 7.5 1.2 11.8 4.6 7.3 1.4 11.8 3.4 7.4 1.3 12.6 4.2 333 12 333 165 -7.6 0 -7.4 -8.1 02/23/2007 03:10:00 7.8 1 10.7 5.7 7.5 1.2 10.7 3.4 7.8 1 10.3 5.3 338 11 338 165 -7.6 0 -7.4 -7.9 02/23/2007 03:20:00 9.3 1.5 13.3 5.3 9.1 1.5 13.3 4.9 9.1 1.4 13 5.3 334 12 357 165 -7.6 0 -7.4 -7.6 02/23/2007 03:30:00 8.2 1.2 13 5.7 8.1 1.3 13 5.3 8.2 1.2 11.8 5.3 327 9 322 165 -7.6 0 -7.4 -7.9 02/23/2007 03:40:00 9.1 1.6 13.7 5.7 9 1.6 14.1 5.7 8.9 1.5 13.7 5.3 326 11 333 165 -7.5 0 -7.4 -7.6 02/23/2007 03:50:00 10.8 2.2 15.6 6.5 10.5 2.4 16.4 4.2 10.9 2.1 15.6 5.7 342 11 349 165 -7.5 0.1 -7.2 -7.6 02/23/2007 04:00:00 7.9 1.5 11.8 4.6 7.5 1.5 10.7 3 8 1.5 11.5 4.6 336 16 351 165 -7.5 0 -7.2 -7.6 02/23/2007 04:10:00 7.4 1 9.5 5.3 7.2 1.2 9.5 3.4 7.4 1 9.5 4.6 334 15 330 165 -7.5 0 -7.4 -7.6 02/23/2007 04:20:00 9.7 1.8 14.5 5.7 9.6 1.8 14.1 5.7 9.7 1.8 14.1 5.3 334 9 332 165 -7.5 0 -7.4 -7.6 02/23/2007 04:30:00 10.4 1.4 14.5 6.1 9.9 1.6 13.3 4.6 10.6 1.3 13.7 6.5 335 13 348 165 -7.5 0 -7.2 -7.6 02/23/2007 04:40:00 8.8 1.2 11.8 5.3 8.5 1.4 12.2 4.9 8.8 1.3 12.2 5.7 336 13 336 165 -7.5 0 -7.2 -7.6 02/23/2007 04:50:00 8.5 1 11.1 5.7 8.3 1 11.1 5.7 8.4 1 11.5 6.1 333 9 347 165 -7.5 0 -7.2 -7.6 02/23/2007 05:00:00 8.6 1.8 12.6 5.3 8.6 1.8 12.6 4.6 8.5 1.7 12.6 5.3 331 14 332 165 -7.5 0 -7.2 -7.9 02/23/2007 05:10:00 8.8 1.5 13.7 6.1 8.2 1.5 12.6 4.9 8.8 1.5 14.5 6.1 339 13 346 165 -7.6 0 -7.4 -7.9 02/23/2007 05:20:00 8.1 1.9 12.6 4.2 7.9 1.8 12.6 4.2 8 2.2 13 3.4 326 17 247 165 -7.4 0 -7.2 -7.6 02/23/2007 05:30:00 6.3 1.1 10.7 3.8 6.3 1.1 10.3 3.8 6.2 1.2 9.1 3.8 330 13 321 165 -7.5 0 -7.2 -7.6 02/23/2007 05:40:00 6.1 1.2 10.3 3.4 6 1.2 9.9 3.4 6.1 1.1 11.1 4.6 331 11 334 165 -7.7 0 -7.4 -7.9 02/23/2007 05:50:00 7.9 1.2 11.8 4.9 7.8 1.2 11.8 5.3 7.9 1.3 12.2 3.8 330 9 333 165 -7.5 0.1 -7.2 -7.6 02/23/2007 06:00:00 9.5 1.5 14.1 6.1 9.2 1.6 14.5 5.7 9.5 1.6 14.5 6.1 332 13 343 165 -7.5 0.1 -7.2 -7.6 02/23/2007 06:10:00 8.7 1.4 12.6 5.7 8.3 1.5 12.6 4.2 8.4 1.5 11.8 5.3 326 17 329 165 -7.4 0 -7.2 -7.6 02/23/2007 06:20:00 8.7 1.5 13 4.9 8.4 1.6 13.3 4.2 8.6 1.5 13.3 4.9 333 13 335 165 -7.5 0 -7.2 -7.6 02/23/2007 06:30:00 8.8 1.7 13 4.9 8.7 1.7 12.6 5.3 8.5 1.7 13 4.9 327 10 330 165 -7.4 0 -7.2 -7.6 02/23/2007 06:40:00 11.4 1.8 14.9 7.2 11.1 1.9 14.9 6.8 11.5 2 16.4 6.1 334 13 336 165 -7.4 0 -7 -7.4 02/23/2007 06:50:00 11 2 15.3 6.5 10.7 2.2 14.5 4.6 10.9 2.2 14.9 5.7 333 13 328 165 -7.2 0 -7 -7.4 02/23/2007 07:00:00 13.6 1.9 17.9 7.6 13.4 2 17.9 7.2 13.4 2 17.6 7.2 336 8 341 165 -7.2 0 -7 -7.4 02/23/2007 07:10:00 12.7 1.8 17.2 8 12.4 2.1 17.2 6.8 12.7 2.1 17.2 6.1 334 14 334 165 -7.2 0 -6.8 -7.4 02/23/2007 07:20:00 12.9 1.7 17.9 8 12.7 1.8 17.6 6.8 12.7 1.8 19.1 7.6 334 9 325 165 -7.1 0 -6.8 -7.4 02/23/2007 07:30:00 12.2 1.9 17.2 8 11.8 2.3 16.8 5.7 12.1 1.9 16.4 7.6 337 12 339 165 -7.1 0 -6.8 -7.2 02/23/2007 07:40:00 12.1 2.3 16.8 6.1 12 2.5 16.8 5.7 12.1 2.3 16.4 5.7 337 11 336 165 -7.2 0 -6.8 -7.4 02/23/2007 07:50:00 11.2 2.2 16.1 6.5 10.9 2.3 16.4 5.7 11.3 2.3 17.6 6.1 338 11 309 165 -7.1 0 -6.8 -7.2 02/23/2007 08:00:00 12.2 1.7 16.4 6.8 11.6 2 16.1 5.7 12 2 17.6 4.9 338 12 332 165 -7 0 -6.8 -7.2 02/23/2007 08:10:00 12.1 1.9 16.1 7.6 11.8 1.9 15.6 7.6 12.2 2 16.4 6.5 334 13 350 165 -6.9 0 -6.8 -7.2 02/23/2007 08:20:00 12.3 1.7 16.8 6.1 11.9 1.9 16.8 5.7 12.3 1.7 15.6 6.1 338 12 339 165 -6.9 0 -6.8 -7 02/23/2007 08:30:00 11.8 2 16.4 6.8 11.5 2.1 16.8 6.8 11.7 2 17.2 6.5 339 10 351 165 -6.9 0 -6.6 -7 02/23/2007 08:40:00 13.4 1.8 18.3 9.9 13 2.4 18.7 6.1 13.5 1.7 17.6 9.5 343 11 310 165 -6.9 0 -6.6 -7.2 02/23/2007 08:50:00 11.6 2.2 17.6 6.1 11 2.5 17.2 5.7 11.5 2.3 17.6 6.5 335 16 332 165 -6.8 0 -6.6 -7 02/23/2007 09:00:00 12.6 1.7 16.4 8 12.4 1.9 16.4 7.6 12.6 1.8 16.8 8.4 338 10 339 165 -6.8 0 -6.6 -7 02/23/2007 09:10:00 12.6 2.3 19.1 7.2 12.5 2.2 17.6 7.6 12.5 2.4 19.1 6.8 334 12 355 165 -6.8 0 -6.6 -6.8 02/23/2007 09:20:00 13 2.2 18.3 8.4 12.4 2.1 17.9 8 13 2.2 17.6 7.6 339 11 349 165 -6.6 0 -6.4 -6.8 02/23/2007 09:30:00 10.9 1.9 15.3 6.1 10.6 1.9 14.5 5.7 11 2 16.4 6.5 336 13 353 165 -6.2 0.1 -5.9 -6.6 02/23/2007 09:40:00 11 2.6 17.2 4.6 10.7 2.6 17.2 4.6 11 2.4 17.2 5.7 336 13 359 165 -6.1 0.1 -5.7 -6.4 02/23/2007 09:50:00 11.9 2.2 17.6 7.6 11.7 2.3 17.9 5.7 11.7 2.2 17.6 7.2 332 13 339 165 -6.4 0 -6.1 -6.6 02/23/2007 10:00:00 10.5 2 16.4 6.1 10.3 2.2 16.8 4.2 10.3 2.2 16.4 4.9 334 17 343 165 -6.2 0 -5.9 -6.6 02/23/2007 10:10:00 11.2 1.7 16.4 7.2 11 1.7 16.8 6.8 11.2 1.8 16.1 5.7 338 11 334 165 -5.8 0.3 -5.3 -6.4 02/23/2007 10:20:00 9.2 1.7 13.7 4.9 8.5 2.1 13.3 3.8 9.1 1.8 13.3 4.6 343 13 341 165 -5.8 0.2 -5.3 -5.9 02/23/2007 10:30:00 9 1.8 14.1 4.2 8.7 1.9 14.1 3.8 8.9 1.8 14.5 3.8 332 15 326 165 -5.7 0.1 -5.3 -6.1 02/23/2007 10:40:00 9.3 2 14.5 5.3 8.8 2 14.1 4.6 9.2 2.1 15.3 4.6 332 17 339 165 -5.8 0.1 -5.5 -6.1 02/23/2007 10:50:00 9.5 1.6 14.1 4.9 9.1 1.9 13.7 4.2 9.4 1.7 14.1 4.9 337 15 328 165 -5.3 0.1 -5 -5.7 02/23/2007 11:00:00 9.9 2 16.1 6.5 9.7 2 15.6 5.3 9.7 1.9 16.1 6.1 333 10 330 165 -5 0.1 -4.6 -5.7 02/23/2007 11:10:00 11.3 1.8 15.6 6.8 10.9 2.2 14.9 5.7 11.3 2 16.4 5.7 338 12 333 165 -5.4 0.3 -4.6 -5.9 02/23/2007 11:20:00 10.2 2.6 15.3 4.6 10.1 2.7 15.3 4.2 10 2.7 16.4 3.8 332 12 325 165 -5.7 0.1 -5.5 -6.1 02/23/2007 11:30:00 11 1.7 14.9 6.8 10.3 2 14.9 6.1 10.9 1.7 14.9 6.8 340 12 341 165 -5.7 0 -5.5 -6.1 02/23/2007 11:40:00 8.4 2 13.7 4.9 8.1 2 13.7 4.2 8.1 2.1 13 3.8 330 17 353 165 -5.4 0.1 -5 -5.7 02/23/2007 11:50:00 9.1 1.4 13.3 5.7 8.5 1.8 13 4.2 9.1 1.4 12.6 6.1 340 15 335 165 -5.2 0.1 -4.8 -5.9 02/23/2007 12:00:00 8 2.3 12.6 4.2 7.5 2 12.6 4.2 7.8 2.2 12.2 3.8 332 18 356 165 -5.4 0 -5.3 -5.7 02/23/2007 12:10:00 6.7 1 9.5 3.8 6.5 1 9.1 3 6.1 0.9 8.8 3.8 315 18 304 165 -4.7 0.4 -3.9 -5.3 02/23/2007 12:20:00 8 1.4 13.7 4.9 7.9 1.4 13.7 4.9 6.9 1.6 13.7 3.8 297 12 278 165 -5.3 0.5 -3.7 -5.7 02/23/2007 12:30:00 8.3 1.1 11.5 5.3 8.2 1.2 11.8 5.3 7.6 1.3 11.8 4.6 304 17 282 165 -5.3 0.3 -4.6 -5.9 02/23/2007 12:40:00 7.8 1.4 11.5 4.2 7.7 1.4 11.1 4.2 6.6 1.3 10.3 2.6 302 16 300 165 -4.7 0.1 -4.4 -5 02/23/2007 12:50:00 7.1 1 9.9 4.6 7.1 1 9.9 4.6 6.3 1.2 9.1 3 305 16 280 165 -4.7 0.2 -4.4 -5.3 02/23/2007 13:00:00 7.5 1.4 12.2 4.2 7.3 1.4 11.8 3.8 6.4 1.3 11.1 3.8 307 18 285 165 -4.6 0.1 -4.4 -5 02/23/2007 13:10:00 7.6 0.9 9.9 5.3 7.5 0.9 9.9 5.3 6.5 1.1 9.5 4.2 301 10 298 165 -4.8 0.2 -4.4 -5 02/23/2007 13:20:00 7.8 1.5 12.6 5.3 7.7 1.5 12.2 4.9 6.9 1.4 12.2 4.2 305 11 290 165 -4.8 0.1 -4.4 -5.5 02/23/2007 13:30:00 7.8 1 11.1 5.3 7.7 1 10.3 5.3 7.2 1 10.3 4.6 316 14 308 165 -4.8 0.2 -4.4 -5.3 02/23/2007 13:40:00 8.2 1.2 11.8 5.7 8.1 1.1 11.5 5.7 6.9 1.2 10.3 4.2 296 10 297 165 -4.9 0.3 -4.2 -5.5 02/23/2007 13:50:00 9 1.3 12.6 6.5 8.9 1.3 12.2 6.1 7.7 1.3 13.3 4.6 303 12 287 165 -5.1 0.1 -4.6 -5.7 02/23/2007 14:00:00 8 1.4 11.8 4.6 7.9 1.4 11.5 4.2 6.9 1.2 9.5 3.8 298 12 289 165 -4.9 0.4 -4.2 -5.7 02/23/2007 14:10:00 8.6 1.5 13.3 4.9 8.5 1.5 13 4.6 7.8 1.9 13 3.8 302 16 295 165 -4.9 0.1 -4.4 -5.3 02/23/2007 14:20:00 9.9 1.7 14.1 6.1 9.8 1.6 14.1 6.1 8.8 1.4 13.3 5.7 309 15 301 165 -4.9 0.1 -4.4 -5.3 02/23/2007 14:30:00 9.7 1.5 14.1 6.1 9.5 1.7 14.9 4.9 9.3 1.5 13.7 6.5 328 15 344 165 -4.6 0.2 -4.2 -5.3 02/23/2007 14:40:00 8.7 1 11.1 6.1 8.5 1 11.1 5.7 8.1 1.5 11.5 4.6 317 18 334 165 -4.7 0.3 -4.2 -5.3 02/23/2007 14:50:00 7.8 1 10.7 5.7 7.7 1 10.3 5.7 7.2 1 10.3 4.6 317 14 300 165 -4.2 0.1 -3.9 -4.6 02/23/2007 15:00:00 7.6 1 10.3 4.9 7.5 1.1 10.3 3.8 7.1 1 10.3 4.6 315 15 311 165 -4.1 0.1 -3.7 -4.4 02/23/2007 15:10:00 8.3 1 11.1 5.3 8.1 1 11.1 5.3 7.7 1 12.2 5.7 319 15 328 165 -4 0.1 -3.5 -4.4 02/23/2007 15:20:00 8.2 1.2 11.1 4.9 7.9 1.2 11.1 4.6 7.9 1.2 10.3 4.9 331 16 353 165 -3.9 0.1 -3.5 -4.4 02/23/2007 15:30:00 8.7 1.2 11.8 6.1 8.6 1.2 12.2 6.1 8.4 1.3 11.1 4.9 324 13 330 165 -4.1 0.1 -3.5 -4.6 02/23/2007 15:40:00 8.9 1 11.8 6.5 8.7 1 11.5 6.1 8.4 1 11.1 6.1 321 13 338 165 -4.5 0 -4.4 -4.6 02/23/2007 15:50:00 9 0.8 12.6 6.8 8.9 0.9 11.8 6.5 8.8 1 11.8 6.1 323 14 321 165 -5 0 -4.6 -5.5 02/23/2007 16:00:00 10.3 1.5 13.7 5.3 10.2 1.5 13.3 6.1 9.7 1.7 14.1 6.5 325 20 337 165 -5.2 0.1 -4.8 -5.7 02/23/2007 16:10:00 10.4 1.7 14.9 5.7 10.2 1.7 14.5 5.7 10 1.7 14.9 6.1 323 16 317 165 -5.4 0.1 -5 -5.9 02/23/2007 16:20:00 9.7 1.2 15.6 6.5 9.5 1.2 16.8 6.5 9.2 1.1 12.6 5.7 320 15 280 165 -5.4 0 -5.3 -5.7 02/23/2007 16:30:00 9.5 1.3 14.9 6.1 9.3 1.3 14.5 5.7 9 1.2 13.3 6.1 324 17 326 165 -5.4 0 -5.3 -5.9 02/23/2007 16:40:00 9.3 1.2 14.5 6.5 9.1 1.3 14.5 5.3 8.8 1.4 14.1 5.3 320 17 346 165 -5.5 0 -5.5 -5.9 02/23/2007 16:50:00 9.8 1.2 13.3 6.1 9.6 1.3 13.3 5.7 9.2 1.1 12.2 6.5 319 16 305 165 -5.5 0 -5.3 -6.1 02/23/2007 17:00:00 9.4 1.3 12.2 5.7 9.3 1.2 12.6 6.1 8.4 1.5 12.2 4.6 308 12 307 165 -5.7 0 -5.3 -6.1 02/23/2007 17:10:00 10.1 1.4 14.1 6.1 10 1.4 14.5 6.1 8.9 1.4 12.6 5.7 303 12 282 165 -5.9 0 -5.7 -6.1 02/23/2007 17:20:00 8.8 1.3 12.2 6.1 8.7 1.3 12.6 4.9 8.1 1.2 11.8 5.3 312 17 312 165 -6 0 -5.7 -6.1 02/23/2007 17:30:00 8.8 1.1 11.8 5.3 8.7 1.1 11.8 5.7 7.9 1.4 13.7 4.2 304 13 298 165 -6.1 0 -5.9 -6.4 02/23/2007 17:40:00 8.1 1 11.1 4.6 8 1.1 11.1 4.9 7.3 1 10.3 4.6 308 13 292 165 -6.1 0 -5.9 -6.4 02/23/2007 17:50:00 9.4 1.1 12.6 6.8 9.3 1.2 12.2 6.5 7.7 1.1 11.8 5.3 301 11 289 165 -6.4 0.1 -6.1 -6.6 02/23/2007 18:00:00 8.7 1.1 11.8 5.3 8.5 1.1 11.5 5.7 7.5 1 9.9 4.9 305 8 293 165 -6.5 0 -6.4 -6.8 02/23/2007 18:10:00 9.5 1.1 13 6.5 9.4 1.1 12.6 6.1 7.7 1.1 11.5 5.3 301 10 298 165 -6.5 0 -6.4 -6.8 02/23/2007 18:20:00 9.4 1.1 12.2 7.2 9.3 1 12.2 6.8 7.7 1.2 11.5 5.3 298 10 282 165 -6.6 0 -6.4 -6.8 02/23/2007 18:30:00 10 1.3 13.7 6.1 9.8 1.3 13 5.7 8.5 1.1 11.8 5.3 301 11 296 165 -6.6 0 -6.4 -6.8 02/23/2007 18:40:00 8.7 1.5 12.2 4.9 8.6 1.4 12.6 5.3 7.1 1.6 11.8 3 297 11 262 165 -6.7 0 -6.6 -6.8 02/23/2007 18:50:00 9 1.5 14.5 4.6 8.9 1.5 14.1 4.6 7.6 1.5 14.1 4.2 301 11 293 165 -6.6 0 -6.4 -6.8 02/23/2007 19:00:00 8.2 1.1 11.1 4.9 8 1 11.1 4.6 7.2 1.2 11.5 3.8 308 13 320 165 -6.9 0.1 -6.6 -7 02/23/2007 19:10:00 9.6 1.1 12.2 6.5 9.5 1.1 12.2 6.5 8 1.1 10.7 5.3 301 9 290 165 -6.7 0 -6.6 -6.8 02/23/2007 19:20:00 9.5 1.1 12.2 6.5 9.4 1.2 11.8 6.1 7.9 1.2 11.5 5.3 303 9 308 165 -6.7 0 -6.6 -6.8 02/23/2007 19:30:00 10.4 1.1 13 7.6 10.2 1.1 13 7.2 8.4 1.2 13.3 6.1 302 9 300 165 -6.7 0 -6.6 -6.8 02/23/2007 19:40:00 10.2 1.3 14.1 7.2 10.1 1.3 13.7 7.2 8.3 1.2 12.2 5.7 302 9 287 165 -6.6 0 -6.6 -6.8 02/23/2007 19:50:00 10.5 0.9 13.3 8 10.4 0.9 13 8 8.5 1.3 12.6 5.3 302 7 310 165 -6.6 0 -6.6 -6.8 02/23/2007 20:00:00 10.4 1 13 8 10.4 1 13 7.6 8 1.1 11.5 5.7 300 8 294 165 -6.7 0 -6.6 -6.8 02/23/2007 20:10:00 10.9 0.9 13.3 7.6 10.7 0.9 13.3 7.6 8.7 1.2 11.5 5.7 303 7 294 165 -6.8 0 -6.6 -6.8 02/23/2007 20:20:00 11.5 0.8 14.5 9.5 11.2 0.7 14.1 9.5 9.8 1 12.2 7.2 307 5 317 165 -6.7 0 -6.6 -6.8 02/23/2007 20:30:00 10.8 0.7 13 9.1 10.6 0.7 13 8.8 9.4 1 12.6 7.2 307 6 302 165 -6.7 0 -6.6 -6.8 02/23/2007 20:40:00 10.9 0.8 14.1 8.4 10.7 0.8 13 8.4 10.1 1 12.6 7.2 311 8 326 165 -6.5 0 -6.4 -6.8 02/23/2007 20:50:00 10.6 0.9 13.3 8.4 10.5 0.9 13 8 9.5 1 11.8 6.8 307 8 295 165 -6.5 0 -6.4 -6.6 02/23/2007 21:00:00 10.8 0.9 14.5 8 10.6 0.9 14.1 8 9.7 0.9 12.2 6.8 309 7 307 165 -6.5 0 -6.4 -6.6 02/23/2007 21:10:00 10.1 1 13.3 6.5 9.9 1 13 6.5 9.2 1.3 13.3 6.5 310 6 315 165 -6.4 0 -6.1 -6.6 02/23/2007 21:20:00 10.2 0.7 12.2 8 10 0.7 11.8 8 9.3 1.1 11.8 6.1 310 7 316 165 -6.4 0 -6.1 -6.8 02/23/2007 21:30:00 10.6 1.2 15.3 7.6 10.5 1.2 15.3 7.2 9.3 1.5 14.5 5.7 307 10 302 165 -6.3 0 -6.1 -6.6 02/23/2007 21:40:00 10.5 1.1 14.1 7.6 10.3 1.1 13.7 7.6 8.8 1.4 13.3 5.3 305 10 316 165 -6.3 0 -6.1 -6.4 02/23/2007 21:50:00 9.6 1.2 14.1 6.8 9.5 1.2 13.7 6.5 7.9 1.4 12.2 4.9 302 9 302 165 -6.3 0 -6.1 -6.6 02/23/2007 22:00:00 9.8 0.9 12.2 6.8 9.6 0.9 11.8 6.8 7.8 0.9 10.7 5.7 301 9 297 165 -6.4 0 -6.1 -6.6 02/23/2007 22:10:00 10 1 12.6 7.2 9.9 1 12.2 7.2 8.3 1.1 11.1 5.3 304 9 304 165 -6.4 0 -6.1 -6.6 02/23/2007 22:20:00 9.9 1.2 14.1 6.5 9.8 1.2 13.7 6.1 8.3 1.2 13 5.3 305 9 304 165 -6.2 0 -6.1 -6.6 02/23/2007 22:30:00 8.3 1.1 11.1 4.9 8.2 1.1 10.7 4.2 7.3 1 9.9 4.9 308 15 315 165 -6.3 0 -6.1 -6.6 02/23/2007 22:40:00 6.7 1.1 9.5 4.6 6.6 1 9.5 4.2 5.6 1 9.1 3.4 301 11 285 165 -6.3 0.1 -6.1 -6.6 02/23/2007 22:50:00 5.6 0.7 7.6 4.2 5.6 0.7 7.6 4.2 4.7 0.9 7.2 2.6 301 9 299 165 -6.4 0 -6.1 -6.6 02/23/2007 23:00:00 4.2 1 6.5 1.9 4.2 1 6.1 2.3 3.9 0.7 5.7 1.9 310 9 310 165 -6.6 0 -6.4 -6.8 02/23/2007 23:10:00 5.8 1 8.8 3 5.6 1 8.4 3.4 4.9 1.1 8 2.6 304 10 298 165 -6.5 0.1 -6.1 -6.8 02/23/2007 23:20:00 4.1 1 7.2 2.3 4.1 1.1 6.8 1.9 3.8 0.7 5.7 1.9 319 14 301 165 -6.6 0.1 -6.1 -6.8 02/23/2007 23:30:00 3.8 0.9 6.5 2.3 3.5 1 6.1 1.1 3.7 0.7 5.7 2.3 333 17 321 165 -6.8 0 -6.6 -6.8 02/23/2007 23:40:00 5.6 1 8.8 2.6 5.5 1 8.4 2.3 4.6 1 8.8 2.6 304 7 306 165 -6.6 0.1 -6.1 -6.8 02/23/2007 23:50:00 6.9 1 10.3 3.8 6.8 1 10.3 3.8 5.9 1.1 9.5 3 306 10 292 165 -6.2 0.1 -6.1 -6.6 02/24/2007 00:00:00 6.7 1 9.5 3.8 6.6 1 9.5 3.8 5.6 1 8.4 2.6 302 8 300 165 -6.2 0 -6.1 -6.6 02/24/2007 00:10:00 6.3 1.1 9.1 3.8 6.2 1 9.1 3.4 5.3 1 8 2.6 298 12 301 165 -6.1 0 -5.7 -6.4 02/24/2007 00:20:00 4.8 1.1 7.2 1.9 4.8 1.1 7.2 2.3 4.1 0.9 7.6 1.9 303 12 297 165 -6 0 -5.7 -6.4 02/24/2007 00:30:00 4 0.7 6.5 1.9 3.9 0.8 6.1 1.9 3.7 0.6 6.1 2.3 310 13 308 165 -6.1 0 -5.7 -6.4 02/24/2007 00:40:00 1.6 1 3.8 0.4 1.4 1 4.2 0.4 1.6 0.9 3.8 0.4 338 36 313 165 -6.2 0 -5.9 -6.4 02/24/2007 00:50:00 3.1 2 7.6 0.4 3.1 1.9 7.2 0.4 3 1.5 6.5 0.4 325 26 310 165 -6.3 0 -6.1 -6.6 02/24/2007 01:00:00 6.5 0.9 9.5 4.2 6.4 0.9 9.5 4.2 5.7 1.1 8.8 3.4 304 12 289 165 -6 0.1 -5.7 -6.1 02/24/2007 01:10:00 7.7 1.1 11.5 5.3 7.6 1.1 11.5 5.7 6.9 1.2 10.7 4.6 309 11 307 165 -5.8 0 -5.5 -5.9 02/24/2007 01:20:00 7.7 1.2 11.1 4.9 7.6 1.2 11.5 5.3 6.9 1.1 10.7 4.2 308 10 295 165 -5.7 0 -5.5 -5.9 02/24/2007 01:30:00 7.4 1.3 12.2 4.2 7.3 1.4 13 4.2 6.4 1.3 10.3 3 309 13 293 165 -5.6 0 -5.5 -5.9 02/24/2007 01:40:00 7.4 1.2 11.1 3.8 7.3 1.2 10.7 4.2 6.5 1.3 10.3 3.8 308 11 308 165 -5.6 0 -5.5 -5.7 02/24/2007 01:50:00 6.2 0.8 8.4 4.2 6.2 0.8 8 3.8 5.2 0.9 7.6 3 306 12 303 165 -5.7 0 -5.5 -5.7 02/24/2007 02:00:00 5.9 1 8.4 3.8 5.8 1 8.4 3.4 5.2 0.8 8 3.4 309 10 297 165 -5.8 0 -5.7 -5.9 02/24/2007 02:10:00 5.4 0.8 7.6 3.8 5.4 0.8 7.6 3.8 4.9 0.8 7.2 2.6 314 10 307 165 -5.9 0 -5.7 -6.1 02/24/2007 02:20:00 5.9 0.8 8.4 4.2 5.8 0.8 8.4 3.8 5.7 1 8.8 3.4 318 10 312 165 -5.9 0 -5.7 -6.1 02/24/2007 02:30:00 7 1.5 11.1 3.4 6.9 1.5 10.7 3.4 6.4 1.4 9.9 3.4 311 10 304 165 -6 0 -5.7 -6.1 02/24/2007 02:40:00 10.4 1.1 14.1 7.6 10.2 1.1 14.5 7.2 9.3 1.2 13.3 6.1 308 10 311 165 -6.1 0 -5.9 -6.4 02/24/2007 02:50:00 11.4 1.5 14.9 8.4 11.2 1.5 15.3 8.4 10.2 1.3 15.3 6.5 308 13 300 165 -6.1 0 -5.9 -6.4 02/24/2007 03:00:00 9.1 1.2 12.2 6.1 9 1.2 11.8 5.7 8.5 1.3 12.2 5.7 312 12 327 165 -6.2 0 -5.9 -6.4 02/24/2007 03:10:00 8.6 1 11.1 5.7 8.5 1 11.1 6.1 7.8 1.2 11.5 4.9 311 13 309 165 -6.4 0 -6.1 -6.6 02/24/2007 03:20:00 7.5 1.3 11.1 4.9 7.3 1.4 10.7 3.4 7.3 1.3 10.3 4.2 333 16 340 165 -6.5 0.1 -6.1 -6.8 02/24/2007 03:30:00 8.3 1.1 11.1 5.7 8.2 1.1 11.8 4.9 7.8 1 10.3 5.3 315 16 295 165 -6.5 0.1 -6.1 -6.8 02/24/2007 03:40:00 9.3 1.5 13.3 5.3 9.2 1.5 13.3 5.3 9.1 1.6 12.6 4.6 321 13 339 165 -6.4 0 -6.1 -6.6 02/24/2007 03:50:00 9.9 1.6 14.9 5.3 9.8 1.6 14.5 4.9 9.3 1.7 14.9 4.9 312 12 310 165 -6.4 0 -6.1 -6.6 02/24/2007 04:00:00 10.4 1.3 13.7 7.6 10.2 1.4 14.1 6.1 9.7 1.2 13 6.8 315 20 290 165 -6.2 0.1 -6.1 -6.6 02/24/2007 04:10:00 9.3 1.5 14.5 5.7 9.1 1.7 14.1 4.2 8.9 1.5 14.1 4.9 332 16 304 165 -6.6 0 -6.4 -6.8 02/24/2007 04:20:00 12.3 1.4 16.1 8 12.1 1.4 16.1 8.4 11.9 1.4 15.6 8.8 312 11 313 165 -6.3 0.1 -6.1 -6.8 02/24/2007 04:30:00 11.3 1.5 14.9 7.2 11.1 1.7 15.3 6.1 10.9 1.6 15.6 6.8 318 20 356 165 -6.4 0 -6.1 -6.6 02/24/2007 04:40:00 11.2 1.2 15.3 8.4 11 1.2 14.9 8.4 10.5 1.1 14.1 7.6 315 12 302 165 -6.6 0 -6.4 -6.8 02/24/2007 04:50:00 10.4 1.5 14.1 7.6 10.2 1.6 14.1 6.5 10.1 1.7 15.6 6.5 325 17 321 165 -6.6 0 -6.4 -6.8 02/24/2007 05:00:00 9.7 1.5 13.3 6.1 9.6 1.5 13.3 5.3 9.7 1.5 13.3 6.5 325 14 315 165 -6.7 0 -6.6 -6.8 02/24/2007 05:10:00 8.7 0.9 10.7 6.1 8.6 0.9 11.1 6.1 8.2 1 11.1 4.9 313 12 325 165 -6.7 0 -6.6 -6.8 02/24/2007 05:20:00 9 1.1 12.6 6.5 8.9 1.1 12.2 6.1 8.3 1.2 13 5.7 314 15 328 165 -6.7 0 -6.6 -6.8 02/24/2007 05:30:00 9.4 1.1 12.6 7.2 9.2 1.1 12.2 6.8 8.9 1.3 13.3 6.1 315 11 327 165 -6.8 0 -6.6 -7 02/24/2007 05:40:00 10.2 1.5 13.7 6.5 10.1 1.5 14.9 6.1 9.9 1.5 14.5 6.5 318 12 310 165 -6.5 0 -6.4 -6.8 02/24/2007 05:50:00 10.7 1.8 15.3 6.5 10.6 2 15.3 6.1 10.5 2 15.6 6.1 333 13 346 165 -6.7 0 -6.4 -6.8 02/24/2007 06:00:00 9.6 1.8 14.5 6.1 9.3 1.9 14.5 5.7 9.3 1.7 14.1 6.1 339 12 320 165 -6.9 0.1 -6.6 -7.2 02/24/2007 06:10:00 10.7 1.6 14.9 6.5 10.4 1.9 14.9 4.6 10.5 1.6 14.5 6.5 332 12 339 165 -7 0 -6.8 -7.2 02/24/2007 06:20:00 8.6 1.1 12.2 6.1 8.5 1.1 12.2 5.7 8.4 1.2 12.6 5.3 330 13 330 165 -7.1 0 -6.8 -7.2 02/24/2007 06:30:00 9.3 1.7 14.1 5.3 9.2 1.8 14.1 4.9 9.2 1.8 13.7 5.7 327 13 343 165 -7.2 0 -7 -7.4 02/24/2007 06:40:00 8.4 1.6 14.1 5.7 8.3 1.7 14.1 5.7 8.2 1.7 13.7 5.3 334 10 312 165 -7.4 0.1 -7.2 -7.6 02/24/2007 06:50:00 9.1 1.4 12.6 6.5 8.6 1.3 12.6 5.7 9 1.5 13 6.1 334 16 336 165 -7.5 0 -7.2 -7.6 02/24/2007 07:00:00 7.9 1.1 10.7 4.2 7.7 1.2 11.1 4.2 7.5 1.2 10.3 4.6 327 18 301 165 -7.5 0 -7.2 -7.9 02/24/2007 07:10:00 8.3 1 11.5 6.1 8.1 1 11.5 4.9 7.8 1 10.7 4.9 317 12 302 165 -7.5 0 -7.2 -7.6 02/24/2007 07:20:00 9 1.3 12.2 6.1 8.8 1.3 12.2 5.3 8.7 1.3 12.6 4.9 334 16 345 165 -7.6 0 -7.2 -7.9 02/24/2007 07:30:00 9.8 1.3 13 5.7 9.1 1.7 13 4.9 9.9 1.3 13.3 6.8 343 14 10 165 -7.8 0 -7.6 -8.1 02/24/2007 07:40:00 10.5 1.5 14.1 6.5 9.6 1.9 14.5 5.3 10.4 1.5 14.5 6.5 342 13 340 165 -7.9 0 -7.6 -8.1 02/24/2007 07:50:00 10.5 1.5 15.6 6.8 10.3 1.5 15.3 6.5 10.3 1.4 13.7 6.1 336 11 261 165 -8 0 -7.9 -8.1 02/24/2007 08:00:00 10.9 1.4 14.5 8 10.9 1.5 14.1 7.6 10.9 1.5 14.9 7.6 336 9 334 165 -8.1 0 -8.1 -8.3 02/24/2007 08:10:00 9.4 1.5 13.3 6.5 9.2 1.5 13.3 6.1 9.4 1.6 13.7 6.5 332 13 334 165 -8.3 0 -8.1 -8.5 02/24/2007 08:20:00 9.3 1.6 13 4.6 9.2 1.6 12.6 4.6 9 1.6 12.6 3.8 334 13 340 165 -8.4 0.1 -8.3 -8.5 02/24/2007 08:30:00 11.3 1.2 15.6 8.4 11.2 1.5 15.6 5.7 11.2 1.2 15.3 7.6 337 12 339 165 -8.5 0 -8.3 -8.5 02/24/2007 08:40:00 12.3 1.3 15.6 8.4 12 1.5 15.6 6.8 12.1 1.3 16.1 8 334 13 354 165 -8.5 0 -8.3 -8.7 02/24/2007 08:50:00 12.1 1.8 16.4 7.2 11.9 2 16.8 7.2 11.8 2 16.4 8 330 17 332 165 -8.5 0 -8.3 -8.7 02/24/2007 09:00:00 10.1 1.5 14.5 7.2 9.9 1.6 14.5 6.1 9.8 1.6 14.9 5.3 325 16 330 165 -8.1 0.1 -8.1 -8.5 02/24/2007 09:10:00 10.8 1.7 16.1 6.8 10.4 1.7 16.1 6.8 10.7 1.7 15.3 6.8 335 12 348 165 -8 0 -7.6 -8.3 02/24/2007 09:20:00 9.5 1.3 12.2 6.5 8.6 1.9 12.2 4.2 9.5 1.5 13 6.1 340 15 313 165 -8 0 -7.6 -8.1 02/24/2007 09:30:00 8.9 1.3 12.6 5.7 8.5 1.7 12.2 3.4 8.9 1.3 12.2 4.9 337 15 332 165 -8 0 -7.6 -8.1 02/24/2007 09:40:00 9 1.1 12.2 6.1 8.6 1.3 13 4.9 8.8 1.3 12.6 5.3 336 12 341 165 -7.9 0 -7.6 -8.1 02/24/2007 09:50:00 9.6 1.3 13.7 6.8 9 1.5 13.7 4.6 9.3 1.3 13.7 5.7 342 11 329 165 -7.7 0 -7.4 -8.1 02/24/2007 10:00:00 10 1.5 14.1 6.8 9.1 1.5 13.3 4.2 9.8 1.6 14.5 6.5 343 14 360 165 -7.7 0 -7.4 -7.9 02/24/2007 10:10:00 9 1.2 12.2 5.3 8.9 1.2 12.2 5.7 8.5 1.2 12.6 4.9 314 12 297 165 -7.2 0.1 -6.8 -7.6 02/24/2007 10:20:00 10.1 1.3 14.5 6.8 10 1.3 14.1 6.8 9.2 1.2 13 5.7 310 13 304 165 -6.9 0.1 -6.6 -7.2 02/24/2007 10:30:00 10.4 1.1 13.3 7.6 10.2 1.1 13 7.6 9.7 1.4 14.5 5.7 313 12 310 165 -7.1 0 -6.8 -7.6 02/24/2007 10:40:00 9.8 1.2 13 5.7 9.6 1.2 12.6 6.8 9.3 1.2 12.2 5.3 315 14 299 165 -6.9 0.1 -6.6 -7.4 02/24/2007 10:50:00 9.5 1.3 13.7 6.5 9.4 1.3 13.3 6.5 9 1.2 12.6 6.5 312 12 300 165 -7.1 0.1 -6.8 -7.6 02/24/2007 11:00:00 9.3 1.5 15.3 5.7 9.2 1.5 15.3 5.7 8.8 1.4 13 4.9 314 14 300 165 -7.1 0.2 -6.8 -7.6 02/24/2007 11:10:00 9.7 1.4 14.5 6.8 9.5 1.4 13.7 6.8 9.2 1.3 13.3 6.5 316 12 302 165 -7 0 -6.8 -7.2 02/24/2007 11:20:00 8.9 1.2 11.8 5.7 8.7 1.2 11.5 5.7 8.4 1.1 11.8 5.3 319 14 311 165 -6.8 0.2 -6.6 -7.4 02/24/2007 11:30:00 9.9 1.5 14.9 6.5 9.8 1.4 14.9 6.1 9 1.3 12.6 5.3 307 12 293 165 -7.2 0.1 -6.8 -7.9 02/24/2007 11:40:00 11 1.3 16.4 8 10.9 1.3 16.1 8 10.2 1.7 15.6 6.5 311 17 319 165 -7.2 0.1 -6.8 -7.6 02/24/2007 11:50:00 11.3 1.2 14.1 8 11.1 1.2 13.7 7.6 10.3 1.3 14.1 6.1 309 12 303 165 -7.3 0 -7 -7.6 02/24/2007 12:00:00 10.5 1.4 14.5 7.6 10.4 1.3 14.1 7.6 9.5 1.4 14.1 5.7 305 10 302 165 -7.3 0.1 -6.8 -7.6 02/24/2007 12:10:00 11.2 1.5 14.1 7.2 11 1.4 14.1 7.2 9.9 1.4 14.1 6.1 308 12 304 165 -7 0.2 -6.6 -7.6 02/24/2007 12:20:00 12.7 1.3 16.8 9.9 12.5 1.3 16.1 9.5 11.3 1.4 15.3 7.2 304 12 297 165 -7.1 0.1 -6.6 -7.6 02/24/2007 12:30:00 12.8 1.2 16.4 8.8 12.6 1.2 16.1 8.8 10.8 1.7 17.6 7.6 302 11 313 165 -7.5 0.3 -6.8 -8.3 02/24/2007 12:40:00 13.2 1.2 17.2 9.9 13 1.1 16.4 9.5 11.3 1.5 16.1 8 303 10 308 165 -7.9 0 -7.6 -8.1 02/24/2007 12:50:00 13.5 1.5 17.2 9.1 13.3 1.5 17.2 9.5 11.8 1.5 15.3 8.4 304 10 305 165 -7.6 0.1 -7.2 -8.1 02/24/2007 13:00:00 14.7 1.3 17.9 11.5 14.6 1.3 17.6 11.5 12.6 1.5 16.4 8.8 304 10 296 165 -7.6 0 -7.4 -7.9 02/24/2007 13:10:00 14.4 1.3 18.3 11.1 14.2 1.2 17.9 10.7 13.4 1.5 17.9 9.9 309 10 310 165 -7.7 0.1 -7.2 -8.1 02/24/2007 13:20:00 14.3 1.6 17.6 9.9 14.1 1.6 17.6 9.9 12.8 1.5 16.8 8.8 307 10 317 165 -7.5 0 -7.2 -7.6 02/24/2007 13:30:00 13.2 1.3 16.1 9.1 13 1.3 15.6 8.8 12 1.4 16.1 8.4 307 10 295 165 -7.4 0 -7.2 -7.6 02/24/2007 13:40:00 13.2 2 17.9 8.4 13 2 17.6 8.4 11.4 1.6 16.4 7.6 304 15 297 165 -7.4 0 -7.2 -7.9 02/24/2007 13:50:00 12.2 1.3 15.3 7.6 12.1 1.3 14.9 7.6 10.7 1.6 13.7 6.8 303 12 310 165 -7.8 0 -7.2 -8.1 02/24/2007 14:00:00 11 1.8 17.2 6.1 10.8 1.8 16.8 5.7 9.9 1.8 14.9 5.7 306 13 296 165 -7.8 0 -7.6 -8.1 02/24/2007 14:10:00 12.8 1.3 16.1 9.1 12.6 1.3 16.1 9.5 12.1 1.7 17.6 8.8 307 13 293 165 -7.8 0 -7.6 -8.1 02/24/2007 14:20:00 13.1 1.4 17.6 9.9 12.8 1.4 17.6 9.9 11.9 1.5 15.6 8 307 10 289 165 -7.9 0.1 -7.4 -8.1 02/24/2007 14:30:00 12.7 1.2 16.1 9.1 12.5 1.2 15.6 8.8 12 1.3 15.3 8.8 310 12 310 165 -7.5 0.4 -6.8 -8.1 02/24/2007 14:40:00 10.7 1.6 14.9 6.5 10.6 1.6 14.5 6.1 9.8 1.6 14.1 5.3 309 15 312 165 -7.6 0.2 -7.2 -8.1 02/24/2007 14:50:00 12.2 1.4 15.3 7.6 12 1.3 15.3 7.6 11.4 1.5 14.9 7.6 309 13 300 165 -7.8 0.2 -7.4 -8.1 02/24/2007 15:00:00 11.2 1.5 16.4 6.8 10.9 1.4 16.4 7.2 10.7 1.5 16.4 7.2 316 15 316 165 -7.9 0.1 -7.6 -8.1 02/24/2007 15:10:00 12.1 1.8 17.2 7.6 11.9 1.7 17.2 8 10.4 1.5 16.4 6.5 301 15 291 165 -7.9 0.1 -7.4 -8.1 02/24/2007 15:20:00 13.6 1.5 17.9 9.5 13.4 1.5 17.2 9.5 12.8 1.7 18.7 8.8 312 17 318 165 -7.9 0.1 -7.4 -8.1 02/24/2007 15:30:00 12.5 2.2 18.3 7.6 12.4 2.2 18.7 6.5 12.3 2.2 17.2 7.6 318 17 336 165 -7.4 0.1 -7 -7.6 02/24/2007 15:40:00 11.6 1.8 19.5 7.2 11.5 1.8 19.1 6.8 11 2.1 18.3 5.3 313 15 321 165 -6.9 0.2 -6.6 -7.2 02/24/2007 15:50:00 9.9 1.5 14.5 5.3 9.8 1.5 14.5 5.3 9.1 1.6 14.9 5.3 312 15 310 165 -6.8 0.2 -6.4 -7.6 02/24/2007 16:00:00 11.4 1.8 20.2 6.5 11.1 1.9 20.6 6.1 10.8 1.9 16.4 5.3 316 19 307 165 -6.9 0.1 -6.6 -7.6 02/24/2007 16:10:00 12.7 2.4 18.7 6.8 12.5 2.4 18.3 6.8 11.8 2.5 18.3 6.1 314 19 324 165 -7.1 0.2 -6.6 -7.6 02/24/2007 16:20:00 12.8 1.5 17.6 9.1 12.6 1.5 17.6 9.1 11.4 1.7 17.9 7.2 302 14 304 165 -7.2 0.3 -6.6 -7.6 02/24/2007 16:30:00 10.7 1.7 14.9 5.7 10.6 1.7 14.9 5.7 9.7 1.6 14.1 4.9 310 14 308 165 -7.8 0 -7.6 -8.1 02/24/2007 16:40:00 11.7 1.8 17.6 8 11.6 1.8 17.6 8 11 2.1 16.4 6.8 309 13 305 165 -8.1 0.1 -7.6 -8.5 02/24/2007 16:50:00 13.9 1.7 18.7 9.9 13.8 1.7 18.7 9.9 13.6 1.8 18.7 9.5 309 14 311 165 -8.5 0.1 -8.1 -8.7 02/24/2007 17:00:00 14.6 1.7 19.9 11.1 14.5 1.7 19.5 9.9 13.6 1.7 18.7 9.5 311 18 309 165 -8.6 0 -8.5 -8.7 02/24/2007 17:10:00 15.6 2.1 21.8 9.1 15.5 2.1 21.8 9.5 15.3 2.3 23.7 9.9 314 14 289 165 -8.6 0 -8.5 -8.7 02/24/2007 17:20:00 14.5 1.8 19.9 9.5 14.3 1.8 19.9 9.9 14.1 2.1 19.1 8.8 311 13 302 165 -8.4 0 -8.1 -8.7 02/24/2007 17:30:00 12.9 1.9 19.1 8.4 12.8 1.8 19.5 8 12 1.7 16.8 7.2 308 15 304 165 -8 0.1 -7.6 -8.5 02/24/2007 17:40:00 11 2 15.3 6.5 10.9 1.9 15.6 6.5 10.5 1.8 14.5 6.5 318 17 260 165 -8 0 -7.6 -8.1 02/24/2007 17:50:00 11.9 1.6 16.8 8.4 11.8 1.6 17.2 8 11.2 1.7 16.4 7.2 315 18 300 165 -8.3 0 -8.1 -8.5 02/24/2007 18:00:00 15.2 2.4 22.1 9.5 15 2.4 22.1 9.5 14.6 2.8 22.1 6.8 310 15 310 165 -8.5 0.1 -8.3 -8.7 02/24/2007 18:10:00 13 2.3 23.7 7.6 12.8 2.4 23.3 7.6 12.3 2.5 20.2 6.8 318 16 280 165 -8.9 0.1 -8.5 -9.1 02/24/2007 18:20:00 10.6 1.5 14.5 7.2 10.1 1.7 14.9 5.7 10.3 1.6 14.9 6.8 333 17 342 165 -9.1 0 -8.9 -9.1 02/24/2007 18:30:00 9.3 1.6 13.3 5.3 8.8 1.9 13.7 4.6 9 1.6 13 5.7 335 20 355 165 -9.1 0 -8.9 -9.3 02/24/2007 18:40:00 12.6 2.1 18.3 7.6 12.4 2.3 18.7 6.5 11.9 2.2 17.6 7.2 318 22 341 165 -9 0 -8.9 -9.1 02/24/2007 18:50:00 14.7 2.2 21.8 9.9 14.5 2.2 22.1 10.3 14.4 2.3 21.4 9.5 328 16 349 165 -9.2 0 -8.9 -9.3 02/24/2007 19:00:00 15.8 2.4 21 8.4 15.7 2.5 20.6 8.8 15.2 2.6 21 8.4 329 14 309 165 -9.2 0 -9.1 -9.7 02/24/2007 19:10:00 16.3 2.7 22.9 9.5 16 2.7 23.3 8.4 16 2.7 23.3 10.3 332 14 324 165 -9.2 0 -9.1 -9.5 02/24/2007 19:20:00 15.2 2.3 22.1 10.7 14.9 2.3 22.6 10.7 14.7 2.2 22.6 9.5 317 15 300 165 -9.2 0 -9.1 -9.3 02/24/2007 19:30:00 16.1 2 23.7 12.2 15.8 2.1 24 11.1 15.6 1.7 21.8 10.7 318 18 298 165 -9.2 0 -9.1 -9.3 02/24/2007 19:40:00 16.6 2.2 23.3 10.7 16.4 2.2 23.3 10.7 16 2.2 23.3 10.3 313 15 324 165 -9.2 0 -9.1 -9.3 02/24/2007 19:50:00 13.5 2.3 21 8.8 13.1 2.2 20.6 8.8 12.8 2.3 19.5 7.6 327 18 322 165 -9.2 0 -9.1 -9.3 02/24/2007 20:00:00 12.2 1.8 17.6 6.8 12 1.8 17.2 6.1 11.5 1.9 16.8 6.8 326 19 330 165 -9.3 0 -9.1 -9.7 02/24/2007 20:10:00 11.1 2.2 17.9 6.8 10.8 2.2 17.6 5.7 10.7 2.3 17.9 6.5 330 15 327 165 -9.3 0 -9.1 -9.5 02/24/2007 20:20:00 15.3 2.5 21.4 8.8 14.8 2.8 21.4 7.2 15.2 2.5 20.2 9.1 333 17 336 165 -9.2 0.1 -9.1 -9.5 02/24/2007 20:30:00 12.3 2.5 21 8.4 11.9 2.2 19.5 8 12.4 2.7 21.4 7.6 329 17 348 165 -9.2 0 -8.9 -9.3 02/24/2007 20:40:00 11.7 2 17.9 6.8 11.2 1.9 17.2 6.8 11.2 2.2 19.1 6.1 321 21 2 165 -9.2 0 -9.1 -9.5 02/24/2007 20:50:00 11.8 1.3 15.3 6.5 11.6 1.3 14.9 6.8 11.4 1.3 14.5 6.8 316 15 322 165 -9.4 0 -9.1 -9.7 02/24/2007 21:00:00 13.6 1.7 19.9 9.5 13.4 1.7 19.5 8.8 12.4 1.9 19.1 7.2 306 15 295 165 -9.2 0.1 -8.9 -9.7 02/24/2007 21:10:00 14.7 2 20.6 9.5 14.6 1.9 20.2 9.9 14.1 2.1 19.9 9.5 311 14 319 165 -9.2 0 -9.1 -9.3 02/24/2007 21:20:00 16.1 1.3 19.5 12.6 15.8 1.3 19.1 12.2 15.1 1.5 19.1 11.5 307 12 268 165 -9.4 0 -9.1 -9.7 02/24/2007 21:30:00 15.7 1.3 19.1 11.8 15.5 1.3 19.1 11.8 14.4 1.5 20.6 9.9 304 13 322 165 -9.4 0 -9.1 -9.7 02/24/2007 21:40:00 15.4 2 21.8 10.3 15.1 2 21 9.9 14.4 2.1 19.1 9.1 307 15 289 165 -9.3 0 -9.1 -9.5 02/24/2007 21:50:00 16.9 1.8 21.8 12.2 16.7 1.7 21.4 12.2 16.5 2.1 21 11.8 311 15 310 165 -9.3 0 -9.1 -9.3 02/24/2007 22:00:00 19.2 2.2 23.7 13.7 19 2.2 24.4 13.3 18.6 2.2 24.8 13.3 306 14 314 165 -9.3 0 -9.1 -9.5 02/24/2007 22:10:00 20.2 1.7 26.3 15.6 19.9 1.7 26 15.6 19.7 1.7 24.8 16.1 308 12 305 165 -9.6 0 -9.3 -9.7 02/24/2007 22:20:00 20 1.6 26 16.1 19.7 1.6 25.2 15.3 19.5 1.6 24.4 15.6 312 13 307 165 -9.6 0 -9.3 -9.7 02/24/2007 22:30:00 20.6 2 27.9 13.7 20.4 2 27.1 14.1 19.6 2.3 28.3 12.2 305 13 322 165 -9.6 0 -9.3 -9.7 02/24/2007 22:40:00 20.4 2.1 26.3 14.5 20.2 2.1 26.3 14.5 19 2.3 27.1 13.7 304 12 307 165 -9.7 0 -9.5 -10 02/24/2007 22:50:00 20.2 2.8 31.3 13 20 2.8 31.8 13 19.3 2.6 26.8 12.2 308 14 267 165 -9.6 0.1 -9.3 -10 02/24/2007 23:00:00 19 2.6 26 13.3 18.9 2.6 26 13.7 18 2.8 24.8 10.7 306 15 314 165 -9.6 0 -9.3 -10 02/24/2007 23:10:00 20 2.3 27.1 13 19.8 2.3 27.1 12.6 19.2 2.4 26.3 12.6 311 14 314 165 -9.7 0 -9.5 -9.7 02/24/2007 23:20:00 22.5 2.5 29.4 14.1 22.4 2.6 29.4 14.9 21.7 2.8 28.7 12.6 310 13 282 165 -9.7 0 -9.5 -9.7 02/24/2007 23:30:00 22.8 2.2 29.1 17.2 22.7 2.3 28.7 17.2 21.7 2.8 27.9 13.7 312 14 311 165 -9.7 0 -9.5 -10 02/24/2007 23:40:00 23.7 1.7 27.9 19.1 23.4 1.7 27.9 18.3 23.3 1.9 27.9 17.6 315 9 303 165 -9.9 0.1 -9.5 -10.2 02/24/2007 23:50:00 23.5 1.5 27.5 18.3 23.2 1.5 27.1 18.7 23.2 1.8 27.5 18.3 314 9 318 165 -10 0.1 -9.7 -10.2 02/25/2007 00:00:00 25.5 1.2 29.8 22.6 25.2 1.2 29.4 22.1 25.4 1.3 29.8 21.4 310 9 292 165 -10.3 0 -10 -10.4 02/25/2007 00:10:00 24.3 1.3 28.3 19.9 24 1.3 27.5 19.5 24.4 1.2 27.1 20.2 312 9 310 165 -10.3 0 -10.2 -10.6 02/25/2007 00:20:00 23.3 1.3 26.8 18.3 22.9 1.3 26.8 17.9 23.2 1.3 27.9 19.1 312 7 313 165 -10.3 0 -10.2 -10.6 02/25/2007 00:30:00 20.7 1.7 25.6 15.3 20.4 1.7 25.2 15.3 20.2 1.8 25.6 16.4 310 9 301 165 -10.2 0 -10 -10.4 02/25/2007 00:40:00 21.2 1.4 24.8 16.4 20.9 1.4 24.4 16.1 20 1.9 24.8 15.6 305 11 292 165 -10.1 0 -10 -10.2 02/25/2007 00:50:00 20.5 2.2 26.3 13.3 20.3 2.2 26.3 13 19.1 2.9 26.3 11.8 304 15 319 165 -9.7 0.2 -9.3 -10.2 02/25/2007 01:00:00 19 1.9 23.7 13.3 18.7 1.8 22.9 13.7 16.1 2.2 22.1 11.5 297 13 300 165 -9.5 0.1 -9.3 -9.7 02/25/2007 01:10:00 19.3 2 26.8 14.9 19.1 2 26 14.5 17.1 2.7 27.1 11.5 302 14 304 165 -9.3 0.2 -8.9 -9.7 02/25/2007 01:20:00 16 2.1 22.6 11.1 15.8 2.1 22.9 11.1 14.6 2 21.4 9.1 303 13 302 165 -9.1 0.1 -8.9 -9.3 02/25/2007 01:30:00 17.6 2.4 25.6 11.8 17.5 2.4 26.8 11.8 16.2 2.5 26 8.4 311 18 312 165 -8.7 0 -8.5 -9.1 02/25/2007 01:40:00 20.9 3.1 29.8 14.1 20.8 3.1 31.8 14.1 20.1 3.1 31.3 13.3 310 14 309 165 -8.7 0 -8.3 -8.9 02/25/2007 01:50:00 21.1 2.8 27.9 14.1 20.9 2.8 27.9 14.1 20.4 2.9 29.8 13.7 306 13 311 165 -8.4 0 -8.1 -8.9 02/25/2007 02:00:00 16.8 2.5 23.3 10.3 16.7 2.5 23.7 9.5 15.5 2.6 24 9.5 310 20 316 165 -8.5 0 -8.3 -8.7 02/25/2007 02:10:00 17 2.6 26.3 10.7 16.8 2.6 26.8 10.7 15.8 2.9 22.1 9.5 303 17 298 165 -8.2 0 -8.1 -8.5 02/25/2007 02:20:00 18 2.3 24.8 13 17.8 2.4 24 13 16.7 2.6 24.4 10.7 306 16 294 165 -8.3 0 -8.1 -8.5 02/25/2007 02:30:00 20.2 2.9 30.2 14.1 20 2.9 29.4 13.3 19.4 3.2 28.7 13 307 16 286 165 -8.1 0.1 -7.9 -8.5 02/25/2007 02:40:00 20.4 2.4 27.1 13.7 20.2 2.4 26.8 13.3 18.9 2.8 25.2 11.5 306 15 269 165 -8 0 -7.6 -8.1 02/25/2007 02:50:00 20.1 2.5 26.3 11.5 19.9 2.5 26.3 11.1 19.2 2.6 25.6 13 308 15 281 165 -8.1 0 -7.6 -8.3 02/25/2007 03:00:00 20.9 2.8 27.5 14.1 20.7 2.8 27.1 13.7 20.7 3.1 27.9 14.1 314 15 318 165 -8.2 0.1 -8.1 -8.5 02/25/2007 03:10:00 22.4 2.2 28.7 16.4 22.1 2.3 28.7 16.1 21.7 2.5 27.5 14.9 319 15 323 165 -7.9 0.2 -7.6 -8.3 02/25/2007 03:20:00 21.7 2.7 28.7 14.1 21.4 2.7 29.8 13.3 21.5 2.9 28.7 13.3 312 14 297 165 -8.2 0 -8.1 -8.5 02/25/2007 03:30:00 18.2 1.9 22.9 12.2 18 1.9 23.3 12.2 17.4 1.9 22.6 13 309 11 307 165 -8.5 0 -8.3 -8.7 02/25/2007 03:40:00 19 1.8 24 12.2 18.7 1.8 23.7 12.6 18.3 2.3 24.4 13 311 14 303 165 -8.5 0 -8.3 -8.9 02/25/2007 03:50:00 17.7 1.9 22.9 12.6 17 1.9 23.3 11.1 17.2 1.9 24.4 11.8 325 21 334 165 -8.4 0 -8.1 -8.7 02/25/2007 04:00:00 17.9 2.8 24.8 12.2 16.9 2.9 24 9.9 17.7 2.9 25.6 11.1 332 19 357 165 -8.1 0.1 -7.9 -8.5 02/25/2007 04:10:00 15.6 1.5 19.5 10.7 15.4 1.5 19.5 10.3 15.1 1.7 19.5 9.5 319 16 307 165 -8.2 0 -8.1 -8.5 02/25/2007 04:20:00 14.4 1.4 17.9 11.1 14.2 1.4 17.6 11.1 13.7 1.6 17.6 7.6 311 13 307 165 -8.2 0 -7.9 -8.5 02/25/2007 04:30:00 14.3 1.7 19.5 10.3 14.1 1.8 19.5 9.1 13.8 1.9 19.5 9.5 315 16 292 165 -8.2 0.1 -8.1 -8.5 02/25/2007 04:40:00 15.5 2.2 22.9 10.7 14.9 2.3 23.3 8.4 15.2 2.3 24.8 9.1 339 13 332 165 -8 0.1 -7.6 -8.3 02/25/2007 04:50:00 13.8 3.2 21.8 7.2 13.2 3.2 22.1 6.1 13.5 3.1 20.6 8.4 335 16 338 165 -8 0 -7.6 -8.1 02/25/2007 05:00:00 14.8 2.4 22.1 9.5 13.9 2.4 21.4 8.4 14.4 2.6 22.6 8.4 338 18 320 165 -8.1 0 -7.9 -8.3 02/25/2007 05:10:00 11.8 1.7 16.8 8 11.6 1.7 16.1 7.2 10.7 1.5 15.3 6.5 308 17 300 165 -8.5 0.1 -8.3 -8.7 02/25/2007 05:20:00 17 1.9 21.4 12.2 16.8 1.9 21 12.2 15.1 1.8 22.6 9.1 301 15 298 165 -8.5 0 -8.3 -8.5 02/25/2007 05:30:00 13.2 1.7 19.9 8.8 13.1 1.8 20.2 8.8 12.4 1.8 17.6 7.6 314 18 302 165 -8.7 0 -8.5 -8.9 02/25/2007 05:40:00 13.1 2.1 18.7 8 12.7 1.9 18.3 8.4 12 2.1 18.3 6.8 322 22 358 165 -8.8 0 -8.5 -8.9 02/25/2007 05:50:00 14.8 2.4 22.6 9.1 14.4 2.5 22.9 8.4 14.4 2.4 22.1 9.5 333 17 343 165 -8.7 0.1 -8.3 -8.9 02/25/2007 06:00:00 15.6 2.5 24.4 9.1 14.4 2.5 22.9 8.8 15 2.5 23.7 9.1 338 18 341 165 -8.4 0.1 -8.1 -8.7 02/25/2007 06:10:00 16.8 1.9 21 11.1 16.3 2.2 21.8 10.7 16.6 2 23.3 11.8 334 17 333 165 -8.3 0.1 -8.1 -8.7 02/25/2007 06:20:00 15.8 1.9 22.1 11.5 15.4 2.1 22.6 10.7 15.6 2.1 21.4 11.1 330 16 348 165 -8.5 0.1 -8.3 -8.9 02/25/2007 06:30:00 14.1 1.5 17.9 10.7 13.6 1.6 17.6 9.9 13.7 1.7 17.6 9.1 328 19 353 165 -8.5 0 -8.3 -8.7 02/25/2007 06:40:00 16.5 2.1 22.9 11.5 16.2 2.1 22.9 11.5 16.1 2.1 22.6 11.5 318 19 304 165 -8.3 0 -8.1 -8.5 02/25/2007 06:50:00 18.3 1.7 23.7 14.1 18.1 1.8 23.7 13.7 17.9 1.8 24 13 313 16 339 165 -8.4 0 -8.3 -8.7 02/25/2007 07:00:00 20 2.1 26.3 14.5 19.8 2.1 26.3 14.1 19.6 2.2 25.6 13.7 313 15 329 165 -8.4 0 -8.1 -8.7 02/25/2007 07:10:00 21.6 1.5 25.2 16.1 21.2 1.6 25.2 16.1 21.2 1.7 24.4 14.1 311 12 305 165 -8.5 0 -8.3 -8.7 02/25/2007 07:20:00 21.5 1.8 26.3 16.1 21.2 1.7 26.3 16.1 21.2 1.9 25.6 16.4 310 15 308 165 -8.5 0 -8.3 -8.7 02/25/2007 07:30:00 23.1 1.5 26.3 16.4 22.7 1.5 26 16.4 23 1.5 26.3 17.6 310 11 302 165 -8.3 0 -8.1 -8.5 02/25/2007 07:40:00 21.3 1.9 25.6 16.4 21.1 1.9 25.2 16.4 21 2.1 25.6 15.6 309 12 312 165 -8 0 -7.9 -8.3 02/25/2007 07:50:00 21.3 1.7 25.6 16.8 21 1.7 25.6 16.4 20.3 1.5 25.2 16.1 305 13 302 165 -8 0 -7.6 -8.1 02/25/2007 08:00:00 20.3 1.8 27.5 15.6 20 1.8 28.3 15.3 19.7 1.7 24.8 14.9 308 13 299 165 -8.1 0 -7.9 -8.3 02/25/2007 08:10:00 19.4 2 23.7 14.1 19.1 2 23.7 13.7 18.7 2.2 25.2 13 307 15 313 165 -8 0 -7.6 -8.5 02/25/2007 08:20:00 17.9 1.7 22.9 13.7 17.7 1.7 22.6 13.7 16.1 2.1 21.8 11.1 302 13 297 165 -7.8 0.1 -7.4 -8.1 02/25/2007 08:30:00 14.1 1.4 19.1 10.3 14 1.3 19.1 11.1 13.1 1.6 17.9 9.1 305 13 317 165 -7.2 0 -6.8 -7.6 02/25/2007 08:40:00 14.4 2 20.6 9.9 14.2 2 21 9.9 13.8 2.2 19.9 9.1 315 17 304 165 -6.9 0.3 -6.4 -7.4 02/25/2007 08:50:00 15.2 2.1 21 10.3 14.1 2.2 20.6 8.8 15.1 2.3 22.1 9.5 337 17 326 165 -6.6 0.1 -6.4 -6.8 02/25/2007 09:00:00 15.3 1.5 19.1 11.1 14.9 1.9 20.2 9.5 15.5 1.5 19.5 11.1 338 14 354 165 -6.6 0 -6.4 -6.8 02/25/2007 09:10:00 13.7 1.3 17.9 9.5 13.4 1.3 16.8 9.5 13.7 1.3 18.3 10.3 334 12 358 165 -6.4 0.1 -6.1 -6.6 02/25/2007 09:20:00 14.4 1.7 19.9 10.3 13.8 1.7 17.9 8.4 14.3 1.8 19.5 9.9 336 17 258 165 -6.4 0 -6.1 -6.6 02/25/2007 09:30:00 13.2 2.1 19.9 8.8 13.1 2.1 19.9 8.4 13.2 2.2 19.1 8.4 331 15 334 165 -6.3 0 -6.1 -6.4 02/25/2007 09:40:00 11.4 1.5 15.6 8.8 10.9 1.3 14.9 8.4 11.2 1.6 16.4 7.2 327 15 355 165 -5.9 0.1 -5.7 -6.4 02/25/2007 09:50:00 11.3 1 14.5 7.6 11.1 1 14.1 7.2 10.8 1.1 13.7 7.2 315 14 310 165 -5.8 0 -5.7 -5.9 02/25/2007 10:00:00 12.3 1.6 17.6 7.6 12 1.5 16.8 7.6 11.8 1.7 17.9 6.8 318 16 323 165 -5.6 0.2 -5.3 -5.9 02/25/2007 10:10:00 13.1 2.1 17.9 7.6 12.9 2 17.2 7.2 12.4 2 17.2 7.2 315 18 313 165 -5.1 0 -5 -5.5 02/25/2007 10:20:00 13.6 2.5 19.5 8 13.3 2.5 19.5 8 12.7 2.3 19.1 8 312 18 297 165 -4.9 0.1 -4.6 -5.3 02/25/2007 10:30:00 12 2.1 17.2 6.5 11.8 2.1 16.8 6.8 10.8 1.7 15.3 7.2 316 22 295 165 -4.4 0.1 -4.2 -4.8 02/25/2007 10:40:00 13.3 1.6 18.3 9.9 13.1 1.7 18.7 9.1 12.5 1.7 17.9 8.4 316 20 324 165 -4.3 0.1 -3.9 -4.6 02/25/2007 10:50:00 13 2.1 18.3 8 12.7 2.1 17.9 8 12.5 2.1 17.2 8.8 320 18 334 165 -4.2 0.1 -3.9 -4.6 02/25/2007 11:00:00 15.6 2.3 22.1 10.3 15.5 2.2 23.3 10.3 14.5 2.8 21 8 313 22 349 165 -4.1 0.1 -3.5 -4.4 02/25/2007 11:10:00 17.6 2 23.7 12.2 16.9 2.2 22.1 10.7 17 2.1 22.1 11.8 338 15 340 165 -3.8 0.1 -3.5 -4.4 02/25/2007 11:20:00 14.7 1.9 19.5 9.1 14.3 2 19.5 8.8 14.3 2.1 19.1 8 334 15 343 165 -3.6 0.1 -3.3 -4.4 02/25/2007 11:30:00 16.5 1.9 22.1 11.8 15.9 2.3 21.8 10.7 16.2 1.8 21.8 9.9 335 16 338 165 -3.7 0.1 -3.3 -3.9 02/25/2007 11:40:00 16.1 2.6 21.4 9.9 15.8 2.5 22.6 10.3 15.8 2.6 21.8 10.7 332 17 342 165 -3.7 0.1 -3.3 -4.2 02/25/2007 11:50:00 14.2 1.7 19.5 11.1 14 1.8 19.9 9.1 13.7 1.9 19.1 9.5 322 17 339 165 -3.5 0.2 -3.3 -4.4 02/25/2007 12:00:00 14.4 2.5 20.2 7.6 14.3 2.5 19.9 7.6 12.8 2.2 18.3 6.1 301 14 281 165 -3.5 0.1 -3.3 -3.9 02/25/2007 12:10:00 13.7 2.5 20.6 6.5 13.6 2.5 19.9 6.1 12.5 2.2 17.6 6.8 305 16 292 165 -3.3 0.2 -2.8 -3.7 02/25/2007 12:20:00 13.6 2.6 19.1 7.2 13.4 2.6 18.7 6.8 11.9 2.5 17.9 6.5 303 21 279 165 -3 0.2 -2.6 -3.9 02/25/2007 12:30:00 15.3 2.7 22.9 8.4 15.1 2.7 22.6 8 13.8 2.4 21.4 7.2 303 17 310 165 -3.2 0.1 -2.8 -3.5 02/25/2007 12:40:00 17.6 2.7 23.3 10.7 17.4 2.6 22.9 10.3 15.4 2.4 22.9 9.5 299 14 302 165 -3.3 0.1 -2.8 -3.5 02/25/2007 12:50:00 15.4 2.3 22.1 8.8 15.2 2.3 21.8 8.4 14.3 2.5 21 7.6 307 17 299 165 -2.9 0.3 -2.6 -3.3 02/25/2007 13:00:00 15.8 2.9 23.3 8 15.7 2.9 23.3 7.2 14.4 2.9 22.9 7.2 305 17 305 165 -2.6 0.2 -2.1 -3.3 02/25/2007 13:10:00 13.1 2.3 19.9 6.8 13.1 2.4 20.6 6.8 11.4 2.4 19.1 4.6 306 19 302 165 -1.9 0.1 -1.4 -2.6 02/25/2007 13:20:00 12.8 2.6 19.9 2.6 12.8 2.6 20.2 3.4 9.7 3.1 17.9 0.7 300 20 295 165 -1.6 0.2 -1.2 -1.9 02/25/2007 13:30:00 12.6 2.8 20.6 6.1 12.6 2.8 21.4 6.5 10 3.1 18.3 1.1 300 20 288 165 -1.1 0.2 -0.3 -1.4 02/25/2007 13:40:00 15.8 2.7 22.1 9.1 15.7 2.7 22.1 9.1 13.5 3.1 21 6.5 304 16 301 165 -1.3 0.4 -0.3 -2.1 02/25/2007 13:50:00 16.6 2.7 24.4 10.7 16.5 2.8 24.8 10.3 14.2 2.7 21.8 7.2 301 15 296 165 -1.7 0.3 -1.2 -2.1 02/25/2007 14:00:00 19.2 2.4 25.6 9.9 19 2.4 25.6 9.9 16.9 2.5 24.4 9.5 299 13 290 165 -2.1 0.1 -1.9 -2.6 02/25/2007 14:10:00 21.4 2.6 31.8 13.7 21.1 2.6 31.8 13.7 19.4 2.7 30.6 11.5 301 12 326 165 -2 0.2 -1.4 -2.8 02/25/2007 14:20:00 23.8 1.8 29.8 19.1 23.5 1.8 29.8 19.1 21.3 2.1 26 16.1 300 12 297 165 -2.4 0.1 -2.1 -3 02/25/2007 14:30:00 23.4 1.8 26.8 19.1 23.1 1.8 27.9 19.1 21.5 1.9 26.3 16.1 304 11 309 165 -2.5 0.1 -2.1 -2.8 02/25/2007 14:40:00 22.8 2 27.9 17.9 22.5 2 27.5 17.9 21.6 2.3 26 14.1 304 12 306 165 -2.5 0.2 -2.1 -3 02/25/2007 14:50:00 22.1 1.8 26.3 16.8 21.9 1.8 26 17.2 21 2.2 25.6 14.9 306 12 290 165 -2.2 0.1 -1.9 -2.6 02/25/2007 15:00:00 21 2.4 27.9 12.2 20.8 2.4 27.9 12.6 20 2.4 29.8 13 306 13 280 165 -2 0.1 -1.7 -2.6 02/25/2007 15:10:00 19.2 2.1 27.5 14.1 18.9 2.1 27.9 13.7 17.6 2.7 27.1 10.3 304 10 305 165 -1.8 0.2 -1.4 -2.6 02/25/2007 15:20:00 16.5 2.1 21.8 12.2 16.4 2.1 21.4 12.6 14.1 1.8 21.8 8.8 298 12 294 165 -1.7 0.2 -1.2 -2.6 02/25/2007 15:30:00 17.2 2.6 26.3 10.7 17 2.6 26.3 10.7 14.6 2.7 23.7 8.8 297 12 259 165 -1.4 0.1 -1 -1.9 02/25/2007 15:40:00 22.1 2.7 28.3 15.6 21.8 2.7 27.9 15.6 21.2 2.9 29.1 11.5 309 14 310 165 -1.3 0.2 -0.8 -1.7 02/25/2007 15:50:00 22.5 2.4 29.1 16.8 22.2 2.4 29.1 16.4 22.1 2.6 29.1 14.9 313 11 310 165 -1.3 0 -1.2 -1.7 02/25/2007 16:00:00 20.5 2.6 27.9 14.5 20.2 2.6 27.5 14.5 19.8 2.8 27.1 13 313 13 319 165 -1.2 0 -0.8 -1.4 02/25/2007 16:10:00 17.6 2.1 22.6 11.8 17.4 2.1 22.9 11.5 16.3 2.2 21.8 11.1 308 13 304 165 -1.2 0 -1 -1.4 02/25/2007 16:20:00 17.8 1.8 22.6 13.3 17.5 1.7 22.1 13.3 15.2 1.9 21.8 9.5 300 11 282 165 -1.3 0 -1 -1.7 02/25/2007 16:30:00 16.9 2.1 22.6 11.1 16.7 2.1 22.6 11.1 15.1 2.4 22.1 9.5 305 13 298 165 -1.3 0 -1 -1.9 02/25/2007 16:40:00 16.9 2.6 25.2 11.1 16.7 2.6 25.2 10.7 15.6 2.4 22.6 10.3 306 15 280 165 -1.2 0 -1 -1.7 02/25/2007 16:50:00 17.5 2 23.7 11.5 17.3 1.9 24 11.5 16.4 2.2 21.4 10.7 308 14 277 165 -1.3 0.1 -1 -1.7 02/25/2007 17:00:00 19.5 2.3 24.8 12.6 19.3 2.3 24 13 18.1 2.2 23.7 12.2 306 13 305 165 -1.3 0.1 -1.2 -1.9 02/25/2007 17:10:00 17 2.7 26.8 11.1 16.8 2.7 26 10.7 15.9 2.6 24 10.3 307 16 284 165 -1.2 0.2 -0.8 -1.7 02/25/2007 17:20:00 17.7 2.7 25.2 11.1 17.6 2.6 24.8 11.5 16.2 2.5 22.6 8.8 306 14 270 165 -1.1 0.2 -0.8 -1.4 02/25/2007 17:30:00 20 2.4 28.3 8.4 19.8 2.4 29.1 8 18.8 2.2 25.2 11.8 306 12 293 165 -1 0 -0.8 -1.4 02/25/2007 17:40:00 20.5 2.4 29.1 15.6 20.3 2.5 28.7 14.9 19.4 2.5 26 12.6 308 13 289 165 -1.2 0.1 -0.8 -1.9 02/25/2007 17:50:00 21.1 2.4 27.9 13.7 20.9 2.4 27.5 13 19.7 2.3 26.3 14.5 306 12 315 165 -1.2 0.1 -0.8 -1.9 02/25/2007 18:00:00 22.7 2 27.9 16.8 22.5 2 29.1 16.1 20.7 2.3 26.8 13.3 303 11 281 165 -1.2 0 -0.8 -1.4 02/25/2007 18:10:00 24 1.9 29.1 17.9 23.7 1.9 28.3 17.6 22 1.8 26.8 16.1 304 9 298 165 -1.4 0.1 -1.2 -2.1 02/25/2007 18:20:00 24.7 1.7 28.7 19.9 24.5 1.7 29.1 19.5 22.9 1.9 27.5 16.8 302 10 300 165 -1.5 0 -1.4 -1.9 02/25/2007 18:30:00 23.2 1.7 27.5 17.9 22.9 1.7 27.5 18.3 22.1 2.1 27.5 17.2 306 9 304 165 -1.8 0.1 -1.4 -2.1 02/25/2007 18:40:00 22.5 1.5 25.2 17.2 22.2 1.5 25.2 16.4 21.8 1.8 25.2 16.4 308 9 310 165 -2 0 -1.9 -2.1 02/25/2007 18:50:00 20.1 1.5 25.2 15.3 19.8 1.5 24.4 15.3 19.8 1.6 23.3 15.6 312 11 309 165 -2.1 0 -1.9 -2.1 02/25/2007 19:00:00 18.5 1.5 22.1 14.9 18.2 1.5 22.1 14.5 18.2 1.6 23.3 14.1 313 9 304 165 -2.1 0 -1.9 -2.4 02/25/2007 19:10:00 17.8 2.2 26.3 12.2 17.6 2.3 26.3 11.8 16.8 2.1 24.8 12.2 309 12 290 165 -2 0 -1.7 -2.1 02/25/2007 19:20:00 19.5 2 24 14.1 19.3 2 23.7 14.1 19.2 2.4 25.2 13.3 313 13 313 165 -1.7 0 -1.4 -2.1 02/25/2007 19:30:00 16.3 2 21.4 9.5 16.1 2.1 21.8 8.8 15.8 2.3 22.6 9.9 316 17 322 165 -1.7 0 -1.4 -1.9 02/25/2007 19:40:00 16.3 2.1 22.6 11.8 16 2.1 22.9 11.5 15.9 2.2 21.8 11.5 320 17 336 165 -1.7 0 -1.4 -1.9 02/25/2007 19:50:00 17 2.5 25.6 11.8 16.8 2.6 25.6 10.3 16.7 2.5 24.4 11.5 321 15 309 165 -1.7 0 -1.4 -1.9 02/25/2007 20:00:00 17.7 2 22.1 10.7 17.5 2 22.6 11.8 16.8 2.2 22.6 10.7 311 13 310 165 -1.6 0 -1.4 -1.9 02/25/2007 20:10:00 19.4 2 24 13 19.2 2 24 13 18.4 2.2 24.4 11.5 307 11 301 165 -1.6 0 -1.4 -1.9 02/25/2007 20:20:00 17.7 2.3 26.8 12.6 17.5 2.3 28.3 11.8 16.7 2.1 23.7 11.8 308 13 301 165 -1.5 0 -1.2 -1.9 02/25/2007 20:30:00 17.5 2.3 23.7 10.7 17.4 2.3 24.4 11.5 16.6 2.6 22.1 9.1 313 14 293 165 -1.4 0 -1.2 -1.7 02/25/2007 20:40:00 16.9 2.4 21.8 11.1 16.9 2.4 22.1 10.7 15.1 2.7 22.9 8.4 308 15 296 165 -1.4 0.1 -1.2 -1.7 02/25/2007 20:50:00 14.5 1.7 19.1 10.7 14.6 1.7 19.1 9.9 12.4 1.8 17.2 7.6 307 14 292 165 -1.5 0 -1.2 -1.9 02/25/2007 21:00:00 13.9 1.8 19.5 8.8 13.9 1.9 19.9 9.1 12.1 2.1 16.8 5.3 306 13 299 165 -1.8 0.1 -1.4 -1.9 02/25/2007 21:10:00 14.3 1.9 19.9 8.4 14.1 1.9 19.1 8.8 12.7 2.3 17.9 6.5 305 16 268 165 -1.9 0 -1.7 -2.1 02/25/2007 21:20:00 16.8 2.8 22.6 9.5 16.6 2.8 21.8 9.5 15.7 2.4 21 9.1 308 12 294 165 -1.7 0 -1.4 -1.9 02/25/2007 21:30:00 17.9 1.8 23.7 13 17.6 1.9 23.7 12.6 16.9 2.2 24.4 10.7 310 14 318 165 -1.8 0 -1.4 -1.9 02/25/2007 21:40:00 16.4 2.4 22.9 10.7 16.2 2.4 22.6 10.3 15.4 2.7 21.4 8 307 15 314 165 -1.9 0.1 -1.7 -2.1 02/25/2007 21:50:00 16.2 2.2 21 10.7 16.3 2.2 21 11.1 14 2.6 20.2 7.6 303 12 316 165 -2 0 -1.9 -2.1 02/25/2007 22:00:00 16.5 2 21.4 9.9 16.6 2.1 21.4 9.5 14.1 2.5 19.9 7.6 301 14 300 165 -2 0 -1.7 -2.1 02/25/2007 22:10:00 16 2 21.8 11.8 16 2 21.8 11.1 14.6 2.4 21.8 9.1 308 14 302 165 -1.9 0 -1.7 -2.1 02/25/2007 22:20:00 13.6 2.4 19.9 8 13.6 2.4 19.9 8 12.1 2.8 19.1 5.7 308 14 301 165 -1.7 0 -1.4 -1.9 02/25/2007 22:30:00 12.9 2.4 18.3 6.5 12.9 2.4 18.3 5.7 11.4 2.8 17.9 3.4 309 14 303 165 -1.7 0 -1.4 -1.9 02/25/2007 22:40:00 12.8 2.9 21 7.6 12.7 2.8 20.6 7.6 11.7 3.2 21 4.9 312 15 310 165 -1.3 0.1 -1 -1.7 02/25/2007 22:50:00 10.6 2.9 18.3 3.8 10.4 2.8 17.9 3.8 9.6 3.1 17.6 2.6 314 22 331 165 -1.3 0.2 -0.8 -1.4 02/25/2007 23:00:00 11.5 2.3 18.7 6.1 11.3 2.3 17.9 5.3 10.5 2.3 16.4 4.2 318 20 310 165 -0.9 0.1 -0.8 -1.2 02/25/2007 23:10:00 10.5 3.3 24.8 4.2 10.3 3.3 24 3.8 9.1 3.5 21.4 3 318 22 334 165 -0.6 0.1 -0.3 -1 02/25/2007 23:20:00 9 2.2 13.7 1.1 9 2.2 14.5 3.4 6.8 2.5 12.6 1.1 310 21 304 165 -0.8 0.1 -0.5 -1 02/25/2007 23:30:00 10.5 3.5 18.7 1.5 10.4 3.5 18.7 1.9 9.2 3.3 17.9 2.3 314 20 315 165 -0.7 0.1 -0.3 -1 02/25/2007 23:40:00 11.4 3.3 19.5 1.9 11.3 3.3 19.5 1.1 9 2.8 15.6 1.5 300 26 293 165 -0.8 0.1 -0.3 -1.2 02/25/2007 23:50:00 12.3 3.6 20.2 1.9 12.2 3.8 20.2 2.3 10.1 3.6 20.6 2.3 304 23 302 165 -0.9 0.1 -0.5 -1.2 02/26/2007 00:00:00 14 3.2 20.6 4.2 13.9 3.2 21.4 3.4 12 4 21.4 1.1 311 20 327 165 -0.6 0 -0.3 -0.8 02/26/2007 00:10:00 13.3 3.1 22.6 5.3 13.2 3.1 23.3 5.7 11 3.6 22.9 2.3 302 17 302 165 -0.4 0.1 -0.1 -0.8 02/26/2007 00:20:00 14.2 2.7 22.9 8 14.1 2.7 22.1 7.6 12 3.5 22.1 3.4 306 19 317 165 -0.8 0 -0.5 -1 02/26/2007 00:30:00 17.1 3.8 28.3 6.1 17 4 28.7 6.1 14.9 4.7 24 2.6 308 16 302 165 -0.7 0 -0.5 -0.8 02/26/2007 00:40:00 17.7 3.6 26 8.4 17.8 3.8 27.1 8.4 14.8 4.1 23.7 3 300 17 304 165 -0.6 0 -0.5 -0.8 02/26/2007 00:50:00 16.2 2.8 22.1 6.5 16.3 2.9 22.6 8 12.7 3.2 21 3.8 301 15 291 165 -0.7 0 -0.5 -0.8 02/26/2007 01:00:00 15.1 2.8 22.6 7.2 15.1 2.9 23.3 6.5 12.1 3.5 21 1.9 303 17 301 165 -0.9 0 -0.5 -1.2 02/26/2007 01:10:00 15.3 2.8 21.4 7.2 15.4 2.9 21.8 6.1 13.1 3.3 20.2 3 303 18 291 165 -0.9 0 -0.8 -1.2 02/26/2007 01:20:00 12.5 2.9 18.7 4.2 12.5 3.1 19.1 3.8 10.5 3.2 17.6 3.4 305 17 295 165 -0.9 0 -0.8 -1.2 02/26/2007 01:30:00 15 2.9 21.4 5.3 15 3.1 21.8 6.1 12.7 3.3 19.5 3 302 17 301 165 -0.9 0 -0.8 -1.2 02/26/2007 01:40:00 17.5 2.3 23.7 10.3 17.7 2.4 24 11.1 14.6 3.2 21.8 5.3 303 15 306 165 -0.9 0 -0.8 -1.2 02/26/2007 01:50:00 20.4 1.9 26.8 14.5 20.8 2 27.5 14.5 18.8 2.4 25.2 11.8 305 12 307 165 -0.9 0 -0.8 -1.2 02/26/2007 02:00:00 20.7 2.2 26 14.5 20.7 2.2 27.1 14.1 19.6 2.6 26 12.6 311 12 325 165 -0.9 0 -0.8 -1.2 02/26/2007 02:10:00 23.5 2.3 29.1 17.2 23.5 2.2 29.1 16.8 22.5 2.7 28.3 15.6 306 13 307 165 -0.9 0 -0.8 -1.2 02/26/2007 02:20:00 24.5 1.9 29.1 19.5 24.3 1.7 28.3 19.5 23.7 2.1 29.1 17.6 308 12 305 165 -0.8 0 -0.5 -0.8 02/26/2007 02:30:00 24.4 1.9 29.8 19.9 24 1.8 29.8 19.9 24.3 1.9 29.1 19.1 315 10 309 165 -0.8 0 -0.5 -1 02/26/2007 02:40:00 25.2 2 29.8 18.3 24.9 2 29.4 17.9 25 2.3 29.4 17.2 315 12 325 165 -0.6 0 -0.3 -0.8 02/26/2007 02:50:00 24.9 2 32.1 19.1 24.5 2 31.3 18.7 24.7 2 31.3 19.1 314 9 308 165 -0.5 0 -0.3 -0.8 02/26/2007 03:00:00 21.8 2 27.1 16.1 21.5 1.9 26.3 16.1 21.3 2.1 26.8 16.1 309 11 304 165 -0.8 0.2 -0.5 -1.2 02/26/2007 03:10:00 22.4 2.1 27.5 16.1 22.2 2 27.5 16.4 21.8 2.2 27.5 15.3 308 10 310 165 -1 0 -0.8 -1.2 02/26/2007 03:20:00 25 1.5 27.9 20.6 24.6 1.4 27.5 20.6 24.5 1.7 27.5 19.1 309 9 309 165 -0.9 0 -0.8 -1.2 02/26/2007 03:30:00 23.6 1.9 28.3 17.9 23.3 1.8 27.9 18.3 23.7 2.2 29.1 17.6 313 10 319 165 -0.8 0 -0.5 -1.2 02/26/2007 03:40:00 21.1 1.6 25.2 16.4 20.7 1.5 25.2 16.4 20.6 2 25.2 15.6 309 11 260 165 -0.8 0 -0.5 -1 02/26/2007 03:50:00 19.2 1.3 21.8 16.1 18.9 1.3 21.4 15.6 18 1.5 21.4 14.1 306 10 301 165 -1 0 -0.8 -1.2 02/26/2007 04:00:00 19.8 1.3 22.6 15.6 19.5 1.3 22.6 16.1 18.6 1.4 22.6 14.1 307 11 309 165 -0.9 0 -0.5 -1.2 02/26/2007 04:10:00 18 1.5 21.4 13.7 17.7 1.5 21.4 13.7 17.6 1.6 21.4 13 309 11 310 165 -0.8 0 -0.5 -1 02/26/2007 04:20:00 17.4 1.7 22.6 13.7 17.2 1.7 21.8 13.3 15.9 2.1 21.4 9.1 307 10 307 165 -0.7 0 -0.5 -1 02/26/2007 04:30:00 16.9 1.7 21.4 13 16.6 1.7 21.4 12.6 15.6 1.8 19.5 11.8 306 9 300 165 -0.6 0 -0.3 -0.8 02/26/2007 04:40:00 18.1 1.7 23.7 13.7 17.8 1.7 23.7 13.7 17.2 1.9 22.9 13 307 9 301 165 -0.6 0 -0.3 -0.8 02/26/2007 04:50:00 19.2 2 24 14.5 19 2 23.7 14.1 18 2.5 23.3 11.8 305 9 293 165 -0.6 0 -0.3 -0.8 02/26/2007 05:00:00 21.9 1.5 24.8 16.8 21.7 1.5 24.8 17.2 20 2.1 25.6 14.9 304 10 298 165 -0.6 0 -0.5 -0.8 02/26/2007 05:10:00 21.9 1.6 26.3 17.6 21.6 1.6 26.3 16.8 20.9 2.1 26.8 14.9 305 10 314 165 -0.6 0 -0.5 -0.8 02/26/2007 05:20:00 22.5 2 27.5 16.1 22.2 2 27.5 16.8 22.1 2.3 27.1 14.1 308 10 307 165 -0.8 0 -0.5 -0.8 02/26/2007 05:30:00 23.6 1.6 27.9 19.1 23.3 1.6 27.5 18.7 23.5 1.9 28.7 17.9 310 9 305 165 -0.8 0 -0.5 -0.8 02/26/2007 05:40:00 24.3 1.8 29.8 18.3 24 1.8 29.1 18.3 24.1 2.1 29.4 17.9 310 9 312 165 -0.9 0 -0.5 -1 02/26/2007 05:50:00 24.7 1.6 27.9 19.5 24.4 1.6 27.9 19.1 24.6 1.7 28.7 20.2 310 8 316 165 -0.8 0 -0.5 -1 02/26/2007 06:00:00 23.8 1.7 28.3 19.9 23.5 1.7 27.9 19.5 23.5 1.8 29.4 19.5 308 10 310 165 -0.8 0 -0.8 -1 02/26/2007 06:10:00 24.4 1.9 29.1 19.5 24.1 1.9 29.1 19.5 23.4 1.9 28.3 18.7 305 9 302 165 -0.8 0 -0.5 -1 02/26/2007 06:20:00 24.2 1.7 27.9 18.7 23.8 1.7 27.5 18.7 23.1 1.8 27.9 17.9 307 10 312 165 -0.6 0 -0.5 -0.8 02/26/2007 06:30:00 23 1.6 27.1 18.7 22.7 1.6 26.8 18.3 22.3 1.7 26.8 17.6 307 9 278 165 -0.7 0 -0.5 -0.8 02/26/2007 06:40:00 22.9 1.4 26.8 19.1 22.5 1.4 26.3 19.1 22.4 1.8 26.3 15.6 308 10 306 165 -0.7 0 -0.5 -1 02/26/2007 06:50:00 23 1.5 27.1 17.9 22.7 1.5 27.1 17.2 22.7 1.8 27.5 16.8 309 9 315 165 -0.8 0.1 -0.5 -1 02/26/2007 07:00:00 24 1.6 27.5 18.7 23.7 1.6 27.5 19.1 23.9 1.9 28.7 18.7 310 10 301 165 -0.9 0 -0.8 -1 02/26/2007 07:10:00 24.7 1.7 28.7 20.2 24.4 1.6 27.9 20.2 24.3 1.8 28.7 18.7 310 9 310 165 -0.9 0 -0.8 -1 02/26/2007 07:20:00 26.1 2.3 30.6 21.4 25.8 2.2 30.2 20.6 25.9 2.5 30.9 19.9 309 11 305 165 -0.8 0 -0.5 -1 02/26/2007 07:30:00 25.2 2 30.6 19.5 24.8 2 29.8 18.3 24.8 2.2 30.6 17.9 310 11 309 165 -0.8 0 -0.5 -0.8 02/26/2007 07:40:00 25.6 1.5 28.7 21 25.3 1.4 28.3 20.6 25 1.6 28.7 21 307 10 305 165 -0.7 0 -0.5 -0.8 02/26/2007 07:50:00 26.4 1.3 29.8 22.1 26.1 1.3 29.1 22.6 25.8 1.7 30.9 20.6 307 9 310 165 -0.7 0 -0.5 -1 02/26/2007 08:00:00 26.2 1.9 30.2 19.9 25.9 1.8 30.2 19.9 25.4 2 30.6 20.2 305 10 302 165 -0.8 0 -0.5 -0.8 02/26/2007 08:10:00 26 2 30.9 19.5 25.8 1.9 30.6 18.3 25.6 2 30.6 18.3 307 9 304 165 -0.8 0 -0.5 -1 02/26/2007 08:20:00 24.9 1.7 28.7 19.9 24.6 1.7 28.3 19.1 24.4 1.7 28.3 19.9 307 9 298 165 -0.8 0 -0.5 -0.8 02/26/2007 08:30:00 23 1.7 27.9 17.6 22.7 1.7 27.5 17.2 22.4 1.7 27.5 17.2 309 9 310 165 -0.8 0 -0.8 -1 02/26/2007 08:40:00 23.7 1.9 28.7 19.5 23.4 1.9 28.3 19.5 23.2 1.9 28.3 17.9 308 10 306 165 -0.8 0 -0.5 -1 02/26/2007 08:50:00 23.2 2.1 27.9 16.1 22.9 2 27.1 16.1 23.1 2.2 27.5 17.2 310 12 312 165 -0.7 0 -0.5 -0.8 02/26/2007 09:00:00 24.7 1.9 28.7 18.7 24.4 1.8 28.7 19.1 24.4 2.3 30.2 18.3 308 12 305 165 -0.5 0 -0.5 -0.8 02/26/2007 09:10:00 24.3 1.5 27.9 19.1 24 1.5 27.5 18.3 23.4 1.8 29.8 19.5 307 9 310 165 -0.4 0 -0.3 -0.8 02/26/2007 09:20:00 24.1 1.4 27.1 19.9 23.7 1.4 26.8 19.1 22.5 1.7 27.9 18.3 304 9 304 165 -0.5 0 -0.3 -0.8 02/26/2007 09:30:00 23.3 1.3 26.3 18.7 23 1.3 26 19.1 21.3 1.9 26 16.1 303 9 307 165 -0.4 0 -0.3 -0.5 02/26/2007 09:40:00 22.9 1.6 26.3 18.3 22.6 1.6 26 18.3 21.5 1.7 25.6 17.6 305 11 270 165 -0.3 0 -0.3 -0.5 02/26/2007 09:50:00 23.1 1.8 27.5 17.6 22.8 1.7 27.1 17.6 21.9 1.9 26 16.8 304 11 293 165 -0.3 0 -0.3 -0.5 02/26/2007 10:00:00 22.8 1.5 26.3 19.1 22.4 1.5 26 18.3 21.2 1.7 25.6 16.8 304 10 304 165 -0.3 0 -0.1 -0.5 02/26/2007 10:10:00 23.2 1.2 26.3 19.1 23 1.2 26 18.7 20.5 1.8 24.8 15.3 301 11 313 165 -0.3 0 -0.1 -0.5 02/26/2007 10:20:00 21.6 1.5 25.6 17.2 21.3 1.5 25.2 17.2 19.9 1.7 24 15.3 305 9 305 165 -0.1 0 -0.1 -0.3 02/26/2007 10:30:00 21 1.5 24 16.8 20.7 1.5 23.7 16.4 18.7 1.7 22.9 13.3 302 11 309 165 0 0.1 0.2 -0.3 02/26/2007 10:40:00 19.5 1.3 24 16.1 19.2 1.3 23.3 16.1 18.5 1.6 24 13.7 307 11 310 165 0.2 0.1 0.7 0.2 02/26/2007 10:50:00 19.8 1.7 23.7 15.6 19.5 1.6 23.7 14.9 18.3 1.7 22.1 13.7 304 11 303 165 0.2 0.1 0.7 -0.3 02/26/2007 11:00:00 20.7 1.3 23.7 17.2 20.4 1.3 23.3 17.2 18.3 1.6 23.7 13 303 9 294 165 0.2 0.1 0.4 -0.3 02/26/2007 11:10:00 19 1.8 23.7 13.7 18.7 1.7 22.9 13.7 17.2 1.8 22.1 12.6 304 12 314 165 0.3 0.1 0.7 -0.1 02/26/2007 11:20:00 16.7 1.6 20.6 12.6 16.4 1.5 20.2 12.2 15.1 1.7 19.1 11.1 305 13 305 165 0.5 0 0.7 0.2 02/26/2007 11:30:00 17.1 1.3 19.9 13.3 16.8 1.2 19.5 13.3 15.7 1.6 19.5 11.5 306 12 300 165 0.5 0.2 0.9 -0.1 02/26/2007 11:40:00 15.3 1.5 19.1 11.5 15.1 1.5 18.3 11.5 13.9 1.7 19.1 9.5 307 11 322 165 0.8 0.1 1.1 0.4 02/26/2007 11:50:00 14.3 1.7 17.9 11.1 14.1 1.7 17.6 10.7 13.1 2 17.2 8.4 311 8 312 165 0.9 0 1.1 0.7 02/26/2007 12:00:00 14.5 1.7 18.7 10.3 14.3 1.7 17.9 10.3 13.4 1.8 18.7 9.1 309 8 312 165 0.9 0 1.4 0.7 02/26/2007 12:10:00 13 1.7 18.3 9.1 12.7 1.7 17.9 9.1 11.8 1.9 16.8 6.8 310 10 307 165 0.9 0.2 1.4 0.4 02/26/2007 12:20:00 13.5 2.2 18.7 6.8 13.3 2.1 19.1 7.6 12.2 2.3 18.3 7.2 307 13 302 165 1.2 0 1.4 0.9 02/26/2007 12:30:00 13 1.5 17.2 9.1 12.8 1.5 16.8 9.1 11.7 1.6 16.1 8 307 10 300 165 1.2 0 1.6 0.9 02/26/2007 12:40:00 11.5 1.7 15.6 7.2 11.2 1.6 15.6 6.5 10.4 1.9 16.1 6.1 309 12 300 165 1.4 0.1 1.8 1.4 02/26/2007 12:50:00 13.8 1.5 19.5 9.9 13.5 1.4 19.5 9.5 12.6 1.5 18.7 7.6 311 9 313 165 1.4 0.1 1.8 1.4 02/26/2007 13:00:00 13.4 2 18.3 8.8 13.1 2 17.9 8.8 11.6 1.5 16.4 5.7 305 11 292 165 1.3 0.2 1.8 0.9 02/26/2007 13:10:00 13.1 2.6 22.1 7.6 12.9 2.6 22.9 7.2 11.6 2.6 18.7 3.4 305 14 304 165 1.3 0.1 1.6 0.9 02/26/2007 13:20:00 13 2.2 18.7 6.5 12.8 2.2 18.3 6.5 11.6 2.1 16.8 6.1 307 13 301 165 1.7 0 1.8 1.4 02/26/2007 13:30:00 12.5 2.8 17.9 5.7 12.4 2.8 18.3 5.7 11 2.4 16.4 5.3 306 16 262 165 1.1 0.3 1.6 0.2 02/26/2007 13:40:00 13.6 2.4 20.6 7.2 13.5 2.4 21 8 12.7 2.4 19.9 6.8 312 13 290 165 0.7 0.1 0.9 0.2 02/26/2007 13:50:00 13.8 1.5 16.8 9.5 13.5 1.5 16.8 9.5 12.6 1.9 17.2 7.6 308 9 305 165 0.4 0.1 0.7 -0.3 02/26/2007 14:00:00 14.4 1.8 18.3 9.9 14.1 1.8 18.3 9.9 13.1 2.1 18.3 8.4 308 10 313 165 0.4 0.1 0.9 -0.3 02/26/2007 14:10:00 14.7 1.3 19.1 10.7 14.5 1.3 18.3 10.7 13.4 1.8 17.9 8.4 307 9 312 165 0.3 0.1 0.7 -0.3 02/26/2007 14:20:00 17.4 1 20.2 14.5 17.2 1 19.9 14.1 14.4 1.7 18.7 10.3 303 8 293 165 0.3 0.2 0.7 -0.3 02/26/2007 14:30:00 17.4 1.5 21.4 13.7 17.1 1.5 21.4 13.7 14.8 1.8 19.5 10.7 304 7 300 165 0.5 0 0.9 -0.1 02/26/2007 14:40:00 17.2 1.5 21 13.3 17 1.5 20.6 13 13.8 1.7 17.6 8.8 299 9 295 165 0.7 0.1 0.9 0.2 02/26/2007 14:50:00 16.1 1.3 19.5 12.2 15.9 1.3 18.7 12.2 13.7 1.7 17.6 9.5 300 10 297 165 0.7 0.1 0.9 0.2 02/26/2007 15:00:00 16.4 1.5 21 12.6 16.1 1.5 20.6 12.2 13.3 2 19.5 8.8 298 10 304 165 0.6 0 0.9 0.2 02/26/2007 15:10:00 18.5 1.4 21.8 14.5 18.2 1.3 21.8 14.9 16 1.8 19.9 11.5 303 9 297 165 0.6 0 0.9 0.2 02/26/2007 15:20:00 17.5 1.5 21 13 17.2 1.5 21 13 15.6 1.7 21.4 10.3 305 11 309 165 0.5 0 0.7 -0.1 02/26/2007 15:30:00 15.6 1.5 18.7 12.2 15.3 1.4 18.3 11.8 14 1.4 17.6 9.9 307 9 306 165 0.4 0.2 0.9 -0.1 02/26/2007 15:40:00 13 1.7 16.8 8.4 12.8 1.7 16.1 8.4 12.5 1.8 16.8 7.6 317 9 313 165 0.8 0.1 1.1 0.2 02/26/2007 15:50:00 14.9 1.4 20.2 11.1 14.7 1.5 19.9 10.7 13.6 1.6 19.9 9.5 308 11 311 165 0.8 0.1 1.4 0.4 02/26/2007 16:00:00 17 1.9 21 12.6 16.7 1.9 20.2 11.8 14.9 1.9 19.5 10.3 306 9 304 165 0.6 0 0.9 0.2 02/26/2007 16:10:00 17.9 1.3 21 14.5 17.6 1.2 20.6 14.1 16.4 1.7 20.6 11.1 307 8 311 165 0.3 0.2 0.7 -0.3 02/26/2007 16:20:00 17.1 1.1 19.9 14.1 16.8 1.1 19.5 13.3 15.4 1.4 18.3 10.7 304 10 308 165 0.1 0 0.4 -0.3 02/26/2007 16:30:00 17.6 1 19.9 14.9 17.3 0.9 19.9 14.5 14.7 1.4 18.3 9.9 303 8 295 165 0.1 0.1 0.4 -0.3 02/26/2007 16:40:00 17.2 1.2 19.9 13.3 16.9 1.1 19.5 13.3 15.4 1.3 18.7 11.8 307 7 305 165 0.1 0.1 0.4 -0.3 02/26/2007 16:50:00 16.5 1.3 19.5 12.6 16.2 1.3 19.1 12.6 15 1.5 18.7 11.1 306 11 279 165 -0.1 0.1 0.2 -0.8 02/26/2007 17:00:00 16.3 1.3 19.5 13 16 1.3 19.5 13 15 1.5 18.7 11.1 307 9 312 165 -0.1 0 0.2 -0.8 02/26/2007 17:10:00 16.3 1.1 19.5 13.7 16.1 1.1 19.5 13.3 14.8 1.5 19.1 11.5 307 13 300 165 -0.1 0.1 0.2 -0.8 02/26/2007 17:20:00 17.7 1.6 20.6 12.2 17.4 1.5 20.2 12.2 17.2 1.7 21 13 311 9 314 165 0 0 0.2 -0.5 02/26/2007 17:30:00 18 1.1 20.6 14.5 17.7 1.1 20.2 14.1 17.3 1.4 21 14.1 311 9 314 165 -0.1 0 0.2 -0.3 02/26/2007 17:40:00 16 1.5 20.2 11.8 15.7 1.5 19.9 11.5 15.6 1.7 19.9 12.2 313 8 320 165 0 0 0.2 -0.5 02/26/2007 17:50:00 15.6 1.8 19.5 11.1 15.3 1.7 19.5 11.1 15.6 1.7 19.9 10.7 316 10 312 165 0.2 0.1 0.7 -0.3 02/26/2007 18:00:00 16.1 1.2 19.1 13 15.8 1.2 19.1 12.2 15.3 1.6 19.5 11.1 310 11 300 165 0.2 0 0.4 -0.3 02/26/2007 18:10:00 15.8 1.4 20.2 11.8 15.5 1.4 20.6 11.8 13.9 1.9 19.5 9.9 306 13 308 165 0.1 0 0.2 -0.3 02/26/2007 18:20:00 16.8 1.3 20.6 13 16.5 1.3 19.9 13 14.5 1.8 18.3 9.9 303 9 282 165 0 0 0.2 -0.3 02/26/2007 18:30:00 18.5 1.8 22.1 13 18.2 1.7 21.4 13 16.8 1.7 21 11.8 305 11 292 165 -0.1 0 0.2 -0.3 02/26/2007 18:40:00 19.5 1.4 22.9 14.9 19.2 1.4 22.6 14.1 17.7 1.5 21.4 13.3 303 11 300 165 -0.2 0.1 -0.1 -0.3 02/26/2007 18:50:00 17.3 1.1 19.9 14.1 17 1.1 19.5 14.5 15.9 1.7 20.6 10.7 306 10 314 165 -0.3 0 -0.1 -0.5 02/26/2007 19:00:00 16.5 1.5 20.6 10.3 16.2 1.5 20.6 10.3 15.6 1.4 19.1 9.9 308 10 298 165 -0.5 0 -0.3 -0.8 02/26/2007 19:10:00 14 1.5 17.9 10.3 13.8 1.5 17.6 9.9 13.4 1.5 18.3 9.9 316 10 318 165 -0.6 0 -0.5 -0.8 02/26/2007 19:20:00 13.7 1.7 18.3 8 13.6 1.7 17.9 8 12.8 1.8 17.2 7.2 312 11 325 165 -0.5 0 -0.3 -0.8 02/26/2007 19:30:00 13.1 2.1 19.1 8 13 2.1 19.5 7.6 12.1 2.1 17.9 5.7 311 12 260 165 -0.4 0.1 -0.1 -0.8 02/26/2007 19:40:00 13.7 1.7 17.9 9.9 13.5 1.7 17.9 9.5 12.8 1.8 17.2 7.6 309 11 302 165 -0.4 0 -0.3 -0.5 02/26/2007 19:50:00 12.7 1.5 16.1 8.4 12.6 1.4 15.6 8 11.8 1.6 15.3 6.5 312 13 282 165 -0.6 0 -0.3 -0.8 02/26/2007 20:00:00 13.7 1.7 17.6 9.5 13.5 1.6 17.2 9.5 12.9 1.7 17.6 8.8 313 10 313 165 -0.6 0 -0.5 -0.8 02/26/2007 20:10:00 12 1.3 16.1 8.4 11.8 1.3 15.3 8.8 11.2 1.5 15.6 7.6 316 15 323 165 -0.8 0.1 -0.5 -1 02/26/2007 20:20:00 11.2 1.5 14.9 6.8 11.1 1.4 14.5 7.2 10.3 1.7 13.7 4.2 316 9 309 165 -0.9 0 -0.8 -1.2 02/26/2007 20:30:00 12.4 1.2 15.3 9.1 12.2 1.2 15.3 8.8 11.9 1.3 15.3 8.4 313 11 276 165 -0.9 0 -0.8 -1.2 02/26/2007 20:40:00 11.8 1.6 16.1 6.5 11.7 1.6 16.1 6.1 10.8 1.9 15.3 4.9 310 12 319 165 -0.9 0 -0.8 -1 02/26/2007 20:50:00 12.7 2 16.8 4.6 12.5 1.9 16.8 4.9 12.3 2 17.9 4.2 319 12 319 165 -0.9 0.1 -0.5 -1.2 02/26/2007 21:00:00 13.9 1.5 18.3 9.5 13.6 1.5 18.3 9.1 13.5 1.5 17.6 9.9 314 12 303 165 -0.8 0 -0.5 -1 02/26/2007 21:10:00 15.1 1.5 17.6 10.3 14.7 1.4 17.6 10.3 14.1 1.3 16.8 8.8 308 9 308 165 -0.8 0.1 -0.5 -1 02/26/2007 21:20:00 14.9 1.3 17.9 10.7 14.6 1.2 17.2 10.7 13.6 1.4 16.8 9.9 304 13 307 165 -0.9 0 -0.8 -1.2 02/26/2007 21:30:00 17.1 1.3 19.9 13 16.7 1.3 19.5 13 15.7 1.3 18.7 11.1 305 13 310 165 -0.9 0 -0.8 -1.2 02/26/2007 21:40:00 16.7 1.3 19.5 13 16.4 1.3 19.1 12.6 15.1 1.4 18.7 11.1 302 13 304 165 -1 0 -0.8 -1.2 02/26/2007 21:50:00 17.7 1.5 20.6 11.5 17.4 1.5 20.2 11.5 15.4 1.5 19.5 11.1 300 13 301 165 -0.9 0 -0.8 -1.2 02/26/2007 22:00:00 16.3 1.2 18.7 11.8 16 1.2 18.7 11.8 14.1 1.6 18.3 9.5 300 11 310 165 -1 0 -0.8 -1.2 02/26/2007 22:10:00 16 1.5 19.9 11.5 15.7 1.5 19.5 11.8 13.7 1.7 18.3 8.8 298 13 237 165 -1 0 -0.8 -1.2 02/26/2007 22:20:00 15.3 1.5 19.1 11.8 15.1 1.5 19.1 11.5 12.7 1.6 17.9 9.5 295 13 301 165 -1.2 0 -1 -1.4 02/26/2007 22:30:00 15.1 1.5 19.1 11.1 14.8 1.5 19.1 11.1 12.2 1.5 16.1 8 294 11 300 165 -1.2 0 -1.2 -1.4 02/26/2007 22:40:00 14 1.5 17.6 10.3 13.7 1.5 17.2 10.3 11.6 1.5 15.3 8.4 293 15 292 165 -1.3 0 -1.2 -1.4 02/26/2007 22:50:00 13.5 1.5 17.2 9.5 13.3 1.4 16.8 9.1 11.2 1.5 15.3 7.2 296 11 302 165 -1.2 0 -1.2 -1.4 02/26/2007 23:00:00 12.9 1.5 16.8 8.4 12.7 1.4 16.8 8.8 11.6 1.7 16.1 5.7 302 12 301 165 -1.2 0 -1 -1.4 02/26/2007 23:10:00 16.6 1.4 19.9 13 16.3 1.3 19.5 13 13.5 1.7 18.3 9.5 297 12 300 165 -1.1 0 -0.8 -1.2 02/26/2007 23:20:00 14.7 2.9 19.1 4.6 14.5 2.7 18.3 5.3 12.1 2.9 17.2 3 297 13 300 165 -1.2 0 -0.8 -1.4 02/26/2007 23:30:00 9.5 2.3 14.5 3.4 9.5 2.3 14.5 4.6 6.9 2.4 12.2 1.5 293 15 294 165 -1.4 0 -1.2 -1.4 02/26/2007 23:40:00 11.4 1.7 14.9 6.1 11.2 1.7 14.5 5.3 9.1 2.1 13.7 0.7 295 10 303 165 -1.4 0 -1.2 -1.4 02/26/2007 23:50:00 11.5 1.3 14.5 8 11.4 1.3 14.5 8 9.3 1.4 13.3 6.1 290 9 295 165 -0.9 0.2 -0.5 -1.4 02/27/2007 00:00:00 12.2 1.3 15.6 9.5 12.2 1.3 15.6 9.5 10.3 1.7 15.3 6.1 289 7 293 165 -0.7 0.2 -0.1 -1 02/27/2007 00:10:00 12.5 1.2 15.6 8.8 12.5 1.1 15.6 9.1 10.6 1.8 15.3 6.8 290 9 293 165 -0.7 0.1 -0.3 -0.8 02/27/2007 00:20:00 12.5 1.2 16.1 8 12.4 1.2 16.1 8 9.7 1.3 13 6.5 296 10 287 165 -0.4 0.2 -0.1 -0.8 02/27/2007 00:30:00 12 1.2 14.9 9.1 11.9 1.2 14.5 8.8 8.9 1.2 14.1 6.5 297 8 300 165 -0.2 0 0.2 -0.5 02/27/2007 00:40:00 12.5 1.2 15.3 9.5 12.4 1.1 14.9 9.5 9.3 1.3 13.3 6.1 295 8 300 165 -0.2 0.1 0.2 -0.3 02/27/2007 00:50:00 12.8 1.2 16.1 9.5 12.7 1.2 16.1 9.9 9.4 1.2 13.7 6.5 297 8 300 165 -0.4 0.1 0.2 -0.8 02/27/2007 01:00:00 13.4 1 16.8 10.7 13.4 0.9 16.1 11.1 10.3 1.3 13.7 7.6 293 8 302 165 -0.3 0.2 0.2 -0.8 02/27/2007 01:10:00 13.9 1.1 16.8 10.7 13.8 1.1 16.4 10.7 10.5 1.4 15.3 7.2 292 9 299 165 -0.2 0 -0.1 -0.3 02/27/2007 01:20:00 13.4 1.2 15.6 9.9 13.4 1.2 16.1 9.5 10.2 1.5 14.5 6.8 293 9 297 165 0 0 0.2 -0.3 02/27/2007 01:30:00 12 1.2 14.9 9.1 11.9 1.1 14.5 9.1 9.2 1.2 13.7 6.5 292 9 258 165 -0.1 0 0.2 -0.3 02/27/2007 01:40:00 11.8 1 14.5 9.5 11.7 1.1 14.5 9.1 9.2 1.3 13.3 6.8 293 9 297 165 0.1 0 0.4 -0.1 02/27/2007 01:50:00 12 1.2 14.9 9.1 11.9 1.2 14.5 9.1 9 1.2 13.7 6.1 295 9 295 165 -0.2 0 -0.1 -0.3 02/27/2007 02:00:00 12.2 1 14.5 9.5 12.1 1 14.5 9.5 8.9 1.1 12.6 6.5 295 9 296 165 -0.2 0 0.2 -0.5 02/27/2007 02:10:00 11.8 1.3 15.3 8.8 11.7 1.3 15.3 8.8 9.6 1.5 14.9 6.5 301 11 263 165 0.1 0 0.2 -0.1 02/27/2007 02:20:00 11.9 1 14.5 8.8 11.8 1 14.1 8.8 9.1 1.3 13 6.1 298 9 296 165 0.2 0 0.4 -0.1 02/27/2007 02:30:00 12.2 1.1 14.5 8.8 12 1.1 14.5 8.8 9.6 1.1 12.6 7.2 300 10 301 165 0.2 0 0.4 -0.1 02/27/2007 02:40:00 12.7 1.2 15.3 9.1 12.6 1.2 15.3 8.8 9.4 1.1 13.7 6.5 295 9 302 165 0.2 0 0.4 -0.1 02/27/2007 02:50:00 13.8 1.1 16.4 9.9 13.8 1.1 16.4 10.3 10.2 1.2 14.1 7.2 293 10 290 165 0.1 0 0.2 -0.3 02/27/2007 03:00:00 14.3 1.1 16.8 11.5 14.1 1.1 16.4 11.5 10.3 1 14.1 7.6 294 8 300 165 0.1 0 0.4 -0.1 02/27/2007 03:10:00 12.7 1.2 16.1 9.5 12.6 1.2 16.1 9.5 9.5 1.1 13.3 6.8 296 9 296 165 0.2 0.1 0.7 -0.1 02/27/2007 03:20:00 12.5 1.3 14.9 8.4 12.3 1.3 14.9 8.4 9.5 1.2 12.6 6.5 296 10 297 165 0.2 0 0.7 0.2 02/27/2007 03:30:00 10.4 1.1 13.3 6.1 10.2 1.1 13 6.5 8.2 1.1 12.2 5.7 293 11 290 165 0.1 0 0.2 -0.1 02/27/2007 03:40:00 9.4 1 11.5 5.7 9.2 1 11.5 5.7 7.5 1 10.7 4.2 295 12 303 165 0.1 0 0.2 -0.3 02/27/2007 03:50:00 10.1 0.8 11.8 7.2 10 0.8 11.8 7.6 8 0.9 10.7 4.9 297 11 310 165 0.2 0 0.4 -0.1 02/27/2007 04:00:00 10.3 1.4 13.7 6.8 10.2 1.4 13.3 6.5 8.4 1.4 12.6 4.6 294 12 295 165 0.1 0 0.2 -0.1 02/27/2007 04:10:00 12 1.3 14.9 7.6 11.8 1.3 14.5 7.6 9.7 1.3 13 6.1 298 11 305 165 0.2 0 0.4 -0.1 02/27/2007 04:20:00 11.4 1.3 14.9 8 11.3 1.3 14.5 7.6 9.3 1.1 13 6.8 297 13 304 165 0 0.1 0.4 -0.3 02/27/2007 04:30:00 12.9 1.7 16.4 8.8 12.7 1.6 16.4 8.8 10.8 1.7 15.3 7.2 299 13 302 165 -0.1 0 0.2 -0.3 02/27/2007 04:40:00 12.3 1.2 15.6 9.1 12.1 1.2 15.3 8.8 10 1.3 13.7 6.8 298 13 310 165 -0.2 0 -0.1 -0.5 02/27/2007 04:50:00 11.7 1.2 14.1 8 11.5 1.2 14.1 7.6 10 1.3 13 6.5 301 11 307 165 -0.1 0 0.2 -0.3 02/27/2007 05:00:00 11.3 1.5 15.3 7.2 11.1 1.4 14.5 7.2 9.5 1.2 12.6 6.1 297 15 297 165 -0.3 0 -0.1 -0.5 02/27/2007 05:10:00 11.2 1.5 14.9 6.5 11 1.5 14.5 6.5 9.2 1.5 12.6 4.9 294 12 282 165 -0.5 0 -0.1 -0.8 02/27/2007 05:20:00 10.1 1.4 13.7 6.5 10 1.3 13.3 6.8 8.1 1.3 12.2 4.9 293 13 287 165 -0.7 0 -0.5 -0.8 02/27/2007 05:30:00 8.5 1.2 11.5 4.2 8.5 1.2 10.7 4.9 6.5 1.2 10.3 3.4 289 14 295 165 -0.8 0 -0.5 -0.8 02/27/2007 05:40:00 9.4 1.2 11.8 5.3 9.3 1.1 11.5 5.7 7.5 1.1 10.3 4.9 293 15 293 165 -0.9 0 -0.8 -1.2 02/27/2007 05:50:00 8.9 1.2 11.5 5.7 8.8 1.1 11.5 5.7 7.1 1.1 9.9 4.2 295 11 286 165 -0.9 0 -0.8 -1 02/27/2007 06:00:00 8.8 1.2 13 5.7 8.6 1.2 12.6 5.7 6.9 1.3 10.7 2.6 292 11 291 165 -0.8 0 -0.5 -1.2 02/27/2007 06:10:00 9.1 1.3 11.8 5.7 9 1.2 11.5 5.7 7.2 1.3 10.3 3.8 293 12 291 165 -0.8 0.1 -0.5 -1 02/27/2007 06:20:00 7.6 1.7 10.7 2.3 7.5 1.6 10.7 2.3 5.9 1.8 9.1 0.4 292 12 296 165 -0.9 0 -0.8 -1 02/27/2007 06:30:00 3.8 2.8 9.1 0.4 3.6 2.9 9.5 0.4 3.4 2.1 8 0.4 334 47 283 165 -1 0 -0.8 -1.2 02/27/2007 06:40:00 1.2 0.7 3 0.4 0.9 0.6 2.6 0.4 1.4 0.7 3.4 0.4 320 69 230 165 -1.4 0.1 -1 -1.4 02/27/2007 06:50:00 1.7 0.9 4.2 0.4 1.5 1 3.8 0.4 2 0.9 4.2 0.4 107 35 97 165 -1.4 0.1 -1.2 -1.7 02/27/2007 07:00:00 1.1 0.8 3.8 0.4 1 0.8 3.4 0.4 1.4 0.7 3 0.4 149 39 138 165 -1.3 0 -1.2 -1.4 02/27/2007 07:10:00 1.1 0.7 2.6 0.4 0.9 0.6 2.6 0.4 1.7 0.6 3 0.4 165 41 184 165 -1.4 0 -1.2 -1.4 02/27/2007 07:20:00 2.2 1.3 6.1 0.4 2.3 1.5 6.1 0.4 2.7 1.1 6.1 0.7 228 24 245 165 -1.4 0 -1.2 -1.4 02/27/2007 07:30:00 0.7 0.5 2.3 0.4 0.6 0.4 2.3 0.4 1.1 0.6 2.6 0.4 164 61 205 165 -1.5 0 -1.4 -1.7 02/27/2007 07:40:00 3.5 1.5 6.1 0.4 3.6 1.5 6.1 0.4 3.6 1.4 6.1 0.4 293 38 294 165 -1.6 0 -1.4 -1.9 02/27/2007 07:50:00 5.3 0.9 7.2 3 5.4 0.9 7.2 2.6 5.4 1.1 7.6 2.6 288 10 282 165 -1.5 0 -1.2 -1.9 02/27/2007 08:00:00 4.5 0.6 5.7 2.6 4.5 0.6 5.7 2.3 4.3 0.7 6.1 2.3 291 7 298 165 -1.6 0 -1.2 -1.9 02/27/2007 08:10:00 2.9 0.8 4.6 1.1 2.9 0.9 4.9 1.1 3.4 0.8 5.3 1.9 282 11 279 165 -1.5 0.1 -1.4 -1.9 02/27/2007 08:20:00 1.2 0.6 3.4 0.4 1.3 0.6 3 0.4 2.2 0.5 3.8 0.7 290 22 309 165 -1.4 0.1 -1.2 -1.7 02/27/2007 08:30:00 1.6 1 4.2 0.4 1.6 1 4.2 0.4 2.3 0.8 4.2 0.4 288 17 282 165 -1.1 0 -0.8 -1.4 02/27/2007 08:40:00 1.9 0.7 3.8 0.4 2 0.7 3.8 0.4 3.1 0.5 4.6 1.9 282 8 276 165 -1.2 0 -1 -1.4 02/27/2007 08:50:00 3.6 0.5 4.9 2.3 3.7 0.5 4.9 2.6 3.9 0.5 5.3 2.6 277 6 291 165 -1.1 0 -0.8 -1.2 02/27/2007 09:00:00 4.2 0.5 5.7 3 4.2 0.5 5.7 3 4.1 0.6 5.7 2.3 290 8 284 165 -1 0.2 -0.8 -1.4 02/27/2007 09:10:00 3.8 0.5 4.9 2.6 3.8 0.5 4.9 2.6 3.6 0.6 5.3 1.9 295 6 289 165 -0.6 0 -0.3 -0.8 02/27/2007 09:20:00 3.8 0.5 5.3 2.3 3.9 0.5 5.3 2.6 3.3 0.6 4.9 1.9 294 5 294 165 -0.3 0 -0.1 -0.5 02/27/2007 09:30:00 2.5 1.1 4.6 0.4 2.4 1.1 4.6 0.4 2.5 0.6 4.2 1.1 299 8 302 165 -0.4 0.1 -0.1 -0.5 02/27/2007 09:40:00 1.6 0.5 2.6 0.7 1.6 0.5 3 0.4 2.2 0.4 3 1.1 307 12 308 165 -0.2 0 -0.1 -0.5 02/27/2007 09:50:00 0.6 0.3 1.5 0.4 0.4 0.2 1.5 0.4 1.2 0.6 2.3 0.4 25 29 14 165 0.2 0.2 0.7 -0.1 02/27/2007 10:00:00 0.4 0.2 1.1 0.4 0.4 0.1 1.1 0.4 0.6 0.3 1.5 0.4 102 24 102 165 1.1 0.3 1.8 0.7 02/27/2007 10:10:00 0.9 0.5 2.3 0.4 0.7 0.5 1.9 0.4 1.6 0.5 2.6 0.4 142 9 133 165 1.7 0.1 1.8 1.4 02/27/2007 10:20:00 0.4 0 0.4 0.4 0.4 0 0.7 0.4 0.7 0.4 1.5 0.4 121 38 165 165 1.7 0.1 1.8 0.9 02/27/2007 10:30:00 0.4 0.2 1.5 0.4 0.4 0.1 1.1 0.4 0.8 0.4 1.9 0.4 72 12 83 165 1.7 0.2 2.3 1.4 02/27/2007 10:40:00 0.5 0.2 1.1 0.4 0.4 0.1 0.7 0.4 0.8 0.4 1.9 0.4 32 28 16 165 2.3 0.6 3.5 1.1 02/27/2007 10:50:00 0.8 0.6 2.6 0.4 0.6 0.5 2.3 0.4 1 0.7 2.6 0.4 132 53 176 165 3.3 0.3 3.8 2.3 02/27/2007 11:00:00 0.5 0.2 1.9 0.4 0.4 0.1 1.1 0.4 0.8 0.4 1.9 0.4 153 9 164 165 1.9 0.2 2.6 1.6 02/27/2007 11:10:00 0.9 0.7 3 0.4 0.8 0.6 2.6 0.4 1.3 0.8 3 0.4 159 15 145 165 1.8 0.1 2.3 1.6 02/27/2007 11:20:00 1 0.6 2.6 0.4 0.9 0.5 2.3 0.4 1.8 0.4 2.6 1.1 151 10 165 165 1.3 0.1 1.8 0.9 02/27/2007 11:30:00 0.8 0.4 1.9 0.4 0.7 0.4 1.5 0.4 1.4 0.6 2.6 0.4 139 11 146 165 0.9 0.1 1.6 0.7 02/27/2007 11:40:00 0.4 0.2 1.9 0.4 0.4 0.2 1.5 0.4 0.9 0.4 1.9 0.4 141 23 166 165 1.2 0.1 1.6 0.7 02/27/2007 11:50:00 0.4 0 0.7 0.4 0.4 0 0.7 0.4 0.4 0.2 1.5 0.4 169 2 165 165 1.9 0.4 2.8 0.9 02/27/2007 12:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.7 0.4 1.9 0.4 169 1 165 165 3 0.2 3.5 2.6 02/27/2007 12:10:00 0.4 0.1 1.1 0.4 0.4 0.1 1.1 0.4 0.8 0.4 1.9 0.4 169 16 145 165 2.7 0.2 3.3 2.3 02/27/2007 12:20:00 0.4 0 0.4 0.4 0.4 0 0.7 0.4 0.7 0.3 1.5 0.4 117 22 165 165 2.2 0.1 2.8 1.8 02/27/2007 12:30:00 0.5 0.3 1.9 0.4 0.5 0.4 1.9 0.4 0.8 0.6 2.3 0.4 82 43 136 165 3 0.3 3.5 2.6 02/27/2007 12:40:00 0.4 0.1 1.1 0.4 0.4 0.1 1.1 0.4 1 0.4 1.9 0.4 111 18 130 165 2.2 0.1 2.6 1.8 02/27/2007 12:50:00 0.6 0.3 1.9 0.4 0.5 0.3 1.5 0.4 1 0.5 2.3 0.4 124 7 135 165 2.5 0.3 3 1.8 02/27/2007 13:00:00 1.4 0.7 3 0.4 1.3 0.7 3 0.4 2 0.7 3.4 0.4 136 12 153 165 2 0.2 2.6 1.6 02/27/2007 13:10:00 2.6 1.2 4.6 0.4 2.6 1.2 4.6 0.4 3.1 1 4.9 1.1 140 12 130 165 1.8 0.2 2.3 1.4 02/27/2007 13:20:00 1.9 0.6 3.4 0.4 2.1 0.6 3.8 0.4 2.3 0.6 3.8 0.7 134 18 151 165 1.6 0 1.8 1.1 02/27/2007 13:30:00 1.7 0.7 3.4 0.4 2 0.7 3.8 0.4 2.1 0.6 3.8 0.4 122 36 138 165 1.6 0 1.8 1.4 02/27/2007 13:40:00 1.8 0.5 3.4 0.7 2 0.5 3.4 1.1 2.3 0.4 3.4 1.5 60 13 54 165 0.8 0.2 1.6 0.2 02/27/2007 13:50:00 2 0.7 3.8 0.4 2.3 0.7 4.2 0.7 2.4 0.5 3.8 0.7 84 22 116 165 0.7 0.2 1.1 0.4 02/27/2007 14:00:00 1 0.6 3.4 0.4 1.5 0.6 3 0.4 1.6 0.6 3.8 0.4 50 15 73 165 1.1 0.2 1.6 0.7 02/27/2007 14:10:00 0.9 0.6 2.3 0.4 1.3 0.6 2.6 0.4 1.7 0.7 3 0.4 24 21 20 165 2.1 0.3 2.6 1.4 02/27/2007 14:20:00 0.7 0.6 2.6 0.4 0.9 0.8 3 0.4 1.1 0.8 3 0.4 53 66 110 165 2.6 0.2 3 2.3 02/27/2007 14:30:00 1 0.8 2.6 0.4 1.2 1 3 0.4 1.2 0.9 3 0.4 65 64 150 165 2.8 0.2 3.5 2.3 02/27/2007 14:40:00 1.5 0.9 3.8 0.4 1.6 0.9 4.2 0.4 1.8 0.8 4.2 0.4 62 47 44 165 2.3 0.6 3.5 1.6 02/27/2007 14:50:00 1.2 0.8 3 0.4 1.3 0.8 3.8 0.4 1.3 0.8 3.8 0.4 62 47 83 165 2 0.3 2.8 1.4 02/27/2007 15:00:00 2.5 0.6 4.6 1.5 2.6 0.6 4.6 1.5 2.7 0.5 4.2 1.5 75 27 77 165 0.9 0.2 1.6 0.7 02/27/2007 15:10:00 2.1 0.6 3.8 0.4 2.2 0.6 3.8 0.7 2.1 0.6 3.4 0.7 97 22 128 165 1.4 0 1.6 1.1 02/27/2007 15:20:00 1.2 0.8 3 0.4 1.2 0.8 3 0.4 1.2 0.7 3.4 0.4 91 38 114 165 2 0.4 3 1.4 02/27/2007 15:30:00 2 1.3 4.2 0.4 2 1.3 4.2 0.4 2.1 1.1 4.2 0.4 99 41 121 165 2.8 0.3 3.3 1.8 02/27/2007 15:40:00 3.1 0.6 4.6 1.1 3.2 0.6 4.9 1.1 3.3 0.6 5.3 1.5 119 11 104 165 1.4 0.2 1.8 0.9 02/27/2007 15:50:00 2.5 0.6 4.6 1.1 2.5 0.6 4.6 1.1 2.6 0.5 4.2 1.5 118 10 122 165 0.9 0 1.4 0.9 02/27/2007 16:00:00 2.5 0.6 4.2 1.1 2.5 0.6 4.6 1.1 2.7 0.6 4.6 1.1 125 12 114 165 0.9 0.1 1.4 0.7 02/27/2007 16:10:00 2.7 0.5 4.2 1.5 2.7 0.5 3.8 1.5 2.9 0.5 4.2 1.5 127 12 116 165 0.8 0 0.9 0.4 02/27/2007 16:20:00 2.3 0.4 3.4 1.1 2.4 0.4 3.4 1.1 2.5 0.4 3.4 1.5 125 9 129 165 0.4 0 0.7 0.2 02/27/2007 16:30:00 2.7 0.4 3.8 1.5 2.8 0.4 3.8 1.5 2.8 0.4 3.8 1.9 133 9 130 165 0.5 0 0.7 -0.1 02/27/2007 16:40:00 2.2 0.4 3 1.1 2.3 0.4 3 1.5 2.5 0.4 3.4 1.1 133 11 135 165 0.1 0.2 0.7 -0.3 02/27/2007 16:50:00 2.5 0.4 3.8 1.9 2.6 0.4 3.8 1.9 2.8 0.4 3.8 1.9 145 9 133 165 -0.4 0.1 0.4 -0.8 02/27/2007 17:00:00 2.4 0.6 3.8 0.7 2.5 0.5 4.2 1.5 2.7 0.5 4.2 1.5 150 7 153 165 -0.7 0 -0.3 -1 02/27/2007 17:10:00 2.2 0.4 3 1.1 2.5 0.4 3.4 1.5 2.6 0.3 3.4 1.9 138 7 132 165 -0.6 0 -0.3 -0.8 02/27/2007 17:20:00 1.4 0.6 2.6 0.4 1.8 0.5 2.6 0.7 2 0.4 3 1.1 118 8 126 165 -0.6 0 -0.3 -1 02/27/2007 17:30:00 1.2 0.7 2.6 0.4 1.6 0.7 2.6 0.4 1.8 0.7 3 0.4 104 20 110 165 -0.7 0.1 -0.3 -1.2 02/27/2007 17:40:00 0.4 0.2 1.1 0.4 1.1 0.3 1.5 0.4 1.2 0.2 1.9 0.7 48 5 50 165 -1.2 0.1 -0.8 -1.4 02/27/2007 17:50:00 0.9 0.4 1.9 0.4 1.4 0.3 2.3 0.4 1.8 0.3 2.3 0.7 36 2 34 165 -1.7 0.1 -1.2 -2.4 02/27/2007 18:00:00 0.7 0.3 1.5 0.4 1.3 0.3 1.9 0.7 1.7 0.2 2.3 1.1 41 6 48 165 -1.9 0.1 -1.7 -2.6 02/27/2007 18:10:00 0.5 0.2 1.1 0.4 0.8 0.5 1.9 0.4 1.2 0.5 1.9 0.4 27 2 31 165 -2 0 -1.4 -2.1 02/27/2007 18:20:00 0.4 0 0.4 0.4 0.4 0.1 0.7 0.4 0.5 0.2 1.5 0.4 54 15 165 165 -2 0 -1.9 -2.1 02/27/2007 18:30:00 0.4 0.2 1.1 0.4 0.8 0.4 1.5 0.4 1.3 0.3 1.9 0.7 30 7 28 165 -2.2 0 -1.9 -2.4 02/27/2007 18:40:00 0.4 0.1 1.1 0.4 0.9 0.3 1.5 0.4 1.5 0.2 1.9 1.1 24 2 28 165 -2.3 0 -2.1 -2.6 02/27/2007 18:50:00 0.4 0 0.7 0.4 0.8 0.3 1.5 0.4 1.6 0.2 1.9 1.1 20 3 18 165 -2.5 0 -2.1 -2.6 02/27/2007 19:00:00 0.5 0.2 1.1 0.4 0.7 0.3 1.5 0.4 1.4 0.2 1.9 1.1 18 0 18 165 -2.5 0 -2.4 -2.8 02/27/2007 19:10:00 0.4 0 0.7 0.4 0.7 0.3 1.1 0.4 1.6 0.2 2.3 0.7 38 12 34 165 -2.4 0 -2.1 -2.6 02/27/2007 19:20:00 0.4 0.1 0.7 0.4 0.6 0.2 1.1 0.4 1.5 0.2 1.9 0.7 33 0 33 165 -2.4 0 -2.1 -2.6 02/27/2007 19:30:00 0.7 0.4 1.5 0.4 0.9 0.4 1.9 0.4 1.8 0.3 2.3 1.1 35 6 28 165 -2.4 0.1 -2.1 -2.6 02/27/2007 19:40:00 0.8 0.5 1.9 0.4 1.1 0.6 1.9 0.4 1.8 0.3 2.3 1.1 47 6 44 165 -2.4 0 -2.1 -2.6 02/27/2007 19:50:00 1.4 0.2 1.9 1.1 1.6 0.2 1.9 1.1 2.2 0.2 2.6 1.9 44 1 44 165 -2.5 0 -2.1 -2.6 02/27/2007 20:00:00 1.2 0.3 1.9 0.7 1.3 0.3 1.9 0.7 2 0.3 2.6 1.5 36 3 33 165 -2.6 0 -2.6 -2.8 02/27/2007 20:10:00 0.6 0.4 1.9 0.4 0.7 0.5 1.9 0.4 1.7 0.4 2.3 0.4 54 13 57 165 -2.5 0 -2.1 -2.6 02/27/2007 20:20:00 0.5 0.2 1.1 0.4 0.7 0.3 1.5 0.4 1.7 0.2 2.3 1.1 45 1 46 165 -2.4 0 -2.1 -2.6 02/27/2007 20:30:00 1.5 0.3 1.9 0.7 1.5 0.3 2.3 0.7 2.3 0.2 3 1.9 34 2 34 165 -2.5 0 -2.1 -2.8 02/27/2007 20:40:00 1.7 0.3 2.6 1.1 1.7 0.3 2.3 1.1 2.4 0.2 3 1.9 38 2 34 165 -2.6 0 -2.6 -2.8 02/27/2007 20:50:00 2 0.3 2.6 1.1 2 0.3 2.6 1.5 2.6 0.3 3 1.9 43 3 46 165 -2.6 0 -2.6 -2.8 02/27/2007 21:00:00 2 0.3 2.6 1.5 2.1 0.3 2.6 1.5 2.7 0.3 3.4 2.3 52 3 54 165 -2.6 0 -2.6 -2.8 02/27/2007 21:10:00 2.5 0.4 3.4 1.9 2.5 0.4 3.8 1.5 3.1 0.3 3.8 2.3 37 9 39 165 -2.7 0 -2.6 -2.8 02/27/2007 21:20:00 2.4 0.4 3.4 1.9 2.2 0.5 3.4 1.1 3 0.3 3.8 2.3 27 9 34 165 -2.8 0 -2.6 -3 02/27/2007 21:30:00 2.5 0.4 3.4 1.1 2.5 0.4 3.4 0.7 3.1 0.3 3.8 1.9 33 5 31 165 -3 0 -2.6 -3 02/27/2007 21:40:00 3.1 0.4 4.2 2.3 3 0.4 4.2 2.3 3.6 0.3 4.6 2.6 34 3 38 165 -3 0 -2.8 -3.3 02/27/2007 21:50:00 2.4 0.6 3.4 0.7 2.5 0.5 3.4 1.1 3 0.5 3.8 1.1 39 5 31 165 -3.1 0 -2.8 -3.3 02/27/2007 22:00:00 2.9 0.4 3.8 1.9 3 0.4 3.8 2.3 3.5 0.3 4.2 2.6 31 3 33 165 -3.1 0 -3 -3.3 02/27/2007 22:10:00 2.8 0.2 3.4 2.3 2.7 0.3 3.4 1.9 3.4 0.2 3.8 3 24 4 25 165 -3.2 0 -3 -3.3 02/27/2007 22:20:00 2.4 0.3 3 1.9 2.2 0.3 3 1.5 3 0.2 3.4 2.6 19 1 18 165 -3.2 0 -3 -3.5 02/27/2007 22:30:00 1.8 0.3 2.3 1.1 1.4 0.3 2.3 0.7 2.7 0.2 3 2.3 11 1 16 165 -3.2 0 -3 -3.5 02/27/2007 22:40:00 1.5 0.4 2.3 0.7 1.3 0.4 2.3 0.4 2.4 0.4 3 1.5 12 3 7 165 -3.2 0 -3 -3.5 02/27/2007 22:50:00 0.8 0.4 1.9 0.4 0.7 0.4 1.9 0.4 1.5 0.6 2.3 0.4 11 3 13 165 -3.2 0 -3 -3.5 02/27/2007 23:00:00 0.4 0 0.4 0.4 0.4 0.2 1.1 0.4 0.6 0.3 1.1 0.4 205 72 165 165 -3.2 0 -2.8 -3.3 02/27/2007 23:10:00 0.4 0.1 0.7 0.4 0.5 0.2 1.1 0.4 1.1 0.2 1.5 0.4 225 0 225 165 -2.8 0 -2.6 -3 02/27/2007 23:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.8 0.2 1.5 0.4 225 0 165 165 -2.8 0 -2.6 -3 02/27/2007 23:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.6 0.2 1.1 0.4 225 0 165 165 -2.9 0 -2.8 -3 02/27/2007 23:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 225 0 165 165 -2.8 0 -2.6 -3 02/27/2007 23:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0.2 1.1 0.4 225 0 165 165 -2.8 0 -2.6 -2.8 02/28/2007 00:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.7 0.3 1.5 0.4 225 0 165 165 -2.8 0 -2.6 -3 02/28/2007 00:10:00 0.4 0.1 1.1 0.4 0.4 0 0.4 0.4 1.4 0.2 1.9 0.7 222 5 215 165 -2.8 0 -2.6 -2.8 02/28/2007 00:20:00 0.4 0.1 1.1 0.4 0.4 0 0.7 0.4 1 0.5 1.9 0.4 208 4 214 165 -2.8 0 -2.6 -2.8 02/28/2007 00:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.9 0.3 1.5 0.4 201 2 165 165 -2.8 0 -2.8 -2.8 02/28/2007 00:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.6 0.3 1.1 0.4 199 0 165 165 -2.9 0 -2.8 -3 02/28/2007 00:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0.2 1.1 0.4 215 28 165 165 -3 0 -2.8 -3.3 02/28/2007 01:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.6 0.3 1.1 0.4 265 17 165 165 -3.2 0 -3 -3.5 02/28/2007 01:10:00 0.4 0.2 1.1 0.4 0.5 0.2 1.1 0.4 1 0.3 1.5 0.4 189 10 187 165 -3.1 0 -2.8 -3.3 02/28/2007 01:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.7 0.4 1.5 0.4 180 0 165 165 -3 0 -2.8 -3 02/28/2007 01:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.7 0.4 1.5 0.4 188 6 165 165 -3 0 -2.8 -3 02/28/2007 01:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0.1 0.7 0.4 193 0 165 165 -3 0 -2.8 -3.3 02/28/2007 01:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.5 0.2 1.1 0.4 236 9 165 165 -3 0 -2.8 -3.3 02/28/2007 02:00:00 0.7 0.4 1.9 0.4 1 0.6 2.3 0.4 1.2 0.5 2.6 0.4 248 8 255 165 -3 0 -2.8 -3 02/28/2007 02:10:00 1.2 0.3 2.3 0.4 1.4 0.3 2.3 0.7 1.3 0.4 2.3 0.7 277 6 267 165 -3.1 0 -2.8 -3.3 02/28/2007 02:20:00 1.7 0.3 2.6 0.7 1.9 0.3 2.6 1.1 2.1 0.4 3 1.1 259 6 253 165 -3.2 0.1 -3 -3.5 02/28/2007 02:30:00 1.4 0.6 2.6 0.4 1.8 0.4 2.6 0.7 2.2 0.4 3 1.1 255 5 252 165 -3 0 -2.8 -3.3 02/28/2007 02:40:00 1.1 0.3 1.9 0.4 1.7 0.3 2.3 0.7 2 0.2 2.6 1.5 262 11 254 165 -3 0 -2.8 -3.3 02/28/2007 02:50:00 0.7 0.4 1.9 0.4 1.1 0.5 1.9 0.4 1.6 0.4 2.3 0.7 277 3 277 165 -3.1 0 -3 -3.3 02/28/2007 03:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.7 0.2 1.5 0.4 263 0 165 165 -3 0 -2.8 -3.3 02/28/2007 03:10:00 1.2 0.5 2.3 0.4 1.4 0.5 2.3 0.4 1.8 0.4 2.6 0.7 306 9 310 165 -3.2 0 -2.8 -3.5 02/28/2007 03:20:00 1.5 0.5 2.6 0.7 1.6 0.5 2.6 0.7 2 0.4 3 1.1 309 1 309 165 -3.5 0 -3.3 -3.5 02/28/2007 03:30:00 2 0.4 3 1.1 2 0.4 3 1.1 2.5 0.3 3 1.9 326 11 309 165 -3.6 0 -3.3 -3.7 02/28/2007 03:40:00 3 0.6 4.2 1.1 2.9 0.6 4.2 1.1 3 0.5 4.2 1.9 311 7 309 165 -3.7 0 -3.3 -3.9 02/28/2007 03:50:00 3.1 0.5 4.2 1.9 3.1 0.5 4.2 1.9 2.8 0.5 3.8 1.5 305 5 304 165 -3.3 0 -3.3 -3.5 02/28/2007 04:00:00 2.1 0.8 3.8 0.4 2.4 0.7 3.8 0.7 2.2 0.5 3.4 1.1 299 7 299 165 -3.2 0 -3 -3.5 02/28/2007 04:10:00 2.9 0.7 4.2 1.5 3.1 0.6 4.6 1.9 2.8 0.4 3.8 1.9 306 9 291 165 -3.3 0 -3.3 -3.5 02/28/2007 04:20:00 3.1 0.5 4.6 1.9 3.2 0.4 4.6 2.3 3.2 0.4 4.2 1.9 320 11 307 165 -3.4 0 -3.3 -3.5 02/28/2007 04:30:00 3 0.9 4.9 0.7 3 0.9 4.9 0.7 3.1 0.6 4.6 1.5 329 15 307 165 -3.6 0 -3.5 -3.7 02/28/2007 04:40:00 2.6 0.4 3.8 1.5 1.8 0.5 3.4 0.7 2.9 0.4 3.8 1.9 355 11 11 165 -3.7 0 -3.5 -3.9 02/28/2007 04:50:00 2.9 0.4 4.2 1.9 2.3 0.7 3.8 0.7 3.1 0.4 4.2 1.9 350 8 340 165 -3.7 0.1 -3.5 -3.9 02/28/2007 05:00:00 1.3 0.5 3 0.4 1.3 0.6 3 0.4 2 0.4 3.4 0.7 348 21 328 165 -3.6 0 -3.3 -3.7 02/28/2007 05:10:00 1.7 0.7 3.4 0.4 1.6 0.7 3.8 0.4 2.3 0.5 3.4 1.1 10 33 22 165 -3.6 0 -3.3 -3.9 02/28/2007 05:20:00 2.5 0.8 4.2 0.4 2.4 0.8 4.2 0.4 3.1 0.7 4.6 1.5 32 16 32 165 -3.8 0.1 -3.5 -4.2 02/28/2007 05:30:00 2.7 0.6 4.6 1.1 2.4 0.7 4.2 0.7 3.5 0.5 4.6 1.9 23 13 351 165 -4.1 0 -3.9 -4.2 02/28/2007 05:40:00 2.9 0.5 4.2 1.9 2.3 0.7 4.2 0.7 3.6 0.5 4.9 2.3 15 13 15 165 -4.2 0 -3.9 -4.4 02/28/2007 05:50:00 3.2 0.5 4.2 2.3 2.2 0.6 3.8 0.7 3.8 0.5 5.3 2.6 1 9 356 165 -4.2 0 -3.9 -4.4 02/28/2007 06:00:00 3.9 0.5 4.9 2.6 2.8 0.9 4.9 1.1 4.3 0.4 5.3 3.4 359 9 5 165 -4.2 0 -3.9 -4.4 02/28/2007 06:10:00 4.2 0.6 6.5 3 3.6 1.1 6.5 1.5 4.5 0.7 6.8 3 347 11 340 165 -4.1 0 -3.9 -4.4 02/28/2007 06:20:00 5.1 0.9 7.2 2.3 4.7 1.1 6.8 1.9 5.3 0.9 6.8 2.3 344 10 336 165 -4.2 0 -3.9 -4.4 02/28/2007 06:30:00 5.5 0.7 7.2 3.4 5.2 0.9 7.6 2.3 5.7 0.7 7.2 3.8 344 9 350 165 -4.2 0 -4.2 -4.4 02/28/2007 06:40:00 5.2 1 8 3 4.8 1.3 7.2 1.5 5.4 1 8.4 3 346 11 352 165 -4.3 0 -4.2 -4.4 02/28/2007 06:50:00 5.8 0.8 8.4 3 5.1 1 7.2 3 6.1 0.8 8.4 4.2 349 8 351 165 -4.4 0 -4.2 -4.6 02/28/2007 07:00:00 5.1 0.8 7.2 3.4 4.4 0.9 6.5 2.6 5.1 1 7.2 2.6 351 13 354 165 -4.5 0 -4.4 -4.6 02/28/2007 07:10:00 5.3 0.8 7.2 3.4 4.8 1 7.2 2.3 5.8 0.9 7.6 3.8 348 8 347 165 -4.5 0 -4.4 -4.6 02/28/2007 07:20:00 6.2 0.6 8 4.6 5.7 0.9 8 3.4 6.6 0.5 8 5.3 347 8 353 165 -4.7 0 -4.4 -4.6 02/28/2007 07:30:00 6.4 0.8 8.8 4.2 5.4 1.1 8 3 6.7 0.8 8.4 3.8 352 7 355 165 -4.7 0 -4.6 -4.8 02/28/2007 07:40:00 6.8 0.8 8.4 4.6 5.1 1.3 8.8 2.6 7.1 0.7 8.8 4.6 356 6 353 165 -4.7 0 -4.6 -4.8 02/28/2007 07:50:00 6.7 0.8 8.4 4.9 4.7 1.1 8 2.3 7 0.8 8.8 4.9 357 6 357 165 -4.7 0 -4.6 -4.8 02/28/2007 08:00:00 6.8 0.7 8.4 4.6 4.7 1.1 8 2.6 7.1 0.7 8.8 4.9 359 6 351 165 -4.8 0 -4.6 -4.8 02/28/2007 08:10:00 6.9 0.8 8.8 4.6 5.3 1.4 8.8 2.6 7.2 0.8 8.8 4.6 354 6 357 165 -4.8 0 -4.6 -5 02/28/2007 08:20:00 5.9 0.6 7.2 4.2 4.1 0.9 6.5 2.3 6.3 0.6 7.6 4.9 360 9 10 165 -4.8 0 -4.6 -5 02/28/2007 08:30:00 6.2 0.7 8 3.8 4.7 1.1 7.2 2.6 6.6 0.8 8.8 4.2 355 7 355 165 -4.8 0 -4.6 -5 02/28/2007 08:40:00 7.3 0.8 9.5 4.9 6.7 1.3 9.9 4.2 7.5 0.8 9.5 5.3 349 5 347 165 -4.8 0 -4.6 -5 02/28/2007 08:50:00 6.3 0.8 8 3.8 5 1.2 7.6 2.6 6.6 0.6 8.4 5.3 353 7 356 165 -4.9 0 -4.6 -5 02/28/2007 09:00:00 7.8 0.8 9.1 5.7 7.5 1 9.9 4.2 8 0.7 9.5 6.1 348 5 349 165 -4.9 0 -4.8 -5 02/28/2007 09:10:00 6.5 0.8 8.8 4.6 5.7 1.1 8.8 3 6.7 0.8 8.8 4.9 350 6 350 165 -5 0 -4.8 -5 02/28/2007 09:20:00 6.9 0.8 8.8 4.9 6.5 1.2 9.1 3.4 7.2 0.8 8.8 4.6 348 7 349 165 -4.9 0 -4.6 -5 02/28/2007 09:30:00 7.4 0.8 9.9 4.9 7.1 1.1 9.9 4.2 7.4 0.8 9.5 4.9 346 6 341 165 -5 0 -4.8 -5 02/28/2007 09:40:00 7.7 1 11.1 4.6 7 1.5 11.1 3.8 8.1 1 11.1 4.6 348 8 338 165 -5 0 -4.8 -5.3 02/28/2007 09:50:00 7.1 0.8 9.1 4.9 6.6 1.3 9.5 3 7.3 0.7 8.8 5.3 350 7 356 165 -4.8 0.1 -4.4 -5 02/28/2007 10:00:00 7.2 0.6 8.8 5.3 6.4 1.3 9.1 3.4 7.2 0.7 8.8 5.3 350 6 346 165 -4.7 0 -4.4 -4.6 02/28/2007 10:10:00 6.5 0.8 8.4 4.6 6.3 0.9 8.8 4.2 6.6 0.8 8.8 4.6 345 7 347 165 -4.7 0 -4.6 -4.8 02/28/2007 10:20:00 6.1 0.9 8 3.8 5.8 1.1 8.4 3 6.5 0.7 8.8 4.6 344 8 344 165 -4.7 0 -4.6 -4.8 02/28/2007 10:30:00 5.6 0.8 7.2 3.4 4.2 1.1 6.8 1.9 5.8 0.8 7.2 3.4 355 8 5 165 -4.6 0 -4.4 -4.8 02/28/2007 10:40:00 6.1 0.8 8.4 3.8 5.6 1 8.8 3.4 6.3 0.7 8.4 4.9 349 6 350 165 -4.2 0.2 -3.7 -4.6 02/28/2007 10:50:00 6.2 0.6 8 4.6 5.8 1 8 3 6.6 0.7 8 4.9 343 10 353 165 -3.7 0 -3.5 -3.9 02/28/2007 11:00:00 6.4 0.6 8 4.2 6.3 0.7 8.8 3.4 6.6 0.6 8.4 4.9 337 8 313 165 -3.9 0 -3.7 -4.2 02/28/2007 11:10:00 6.5 0.6 8.4 4.9 6.4 0.6 8.4 4.9 6.7 0.6 8.8 4.9 329 9 330 165 -3.8 0.2 -3.3 -4.2 02/28/2007 11:20:00 7.2 0.6 8.8 5.7 7.2 0.7 9.1 4.9 7.3 0.7 9.1 5.3 342 7 351 165 -3.8 0 -3.5 -4.2 02/28/2007 11:30:00 6.6 0.9 8.8 4.2 6.5 0.8 8.4 4.2 6.7 0.8 8.4 4.6 327 13 328 165 -3.9 0 -3.7 -4.2 02/28/2007 11:40:00 7.2 0.9 9.1 4.6 7.1 1 8.8 4.6 7.3 0.8 9.1 4.6 340 9 340 165 -3.9 0 -3.7 -4.2 02/28/2007 11:50:00 8 0.8 9.9 5.7 7.9 0.9 9.9 4.9 8.1 0.8 9.9 5.3 339 9 346 165 -3.7 0 -3.5 -3.9 02/28/2007 12:00:00 8.1 0.7 10.3 6.5 7.8 1.2 9.9 3.8 8.5 0.6 10.7 6.8 345 8 356 165 -3.9 0.1 -3.5 -4.2 02/28/2007 12:10:00 8.4 0.7 10.3 6.5 6.6 1.4 9.9 4.2 8.9 0.6 10.7 7.2 354 6 357 165 -4.2 0 -3.9 -4.6 02/28/2007 12:20:00 7.8 0.6 10.7 6.5 7.8 0.8 10.3 4.6 8.2 0.5 11.1 7.2 344 6 343 165 -4.2 0 -3.9 -4.6 02/28/2007 12:30:00 7.7 0.6 9.5 6.1 7.5 1 9.5 4.2 8 0.6 9.5 6.1 345 6 339 165 -4.1 0 -3.9 -4.4 02/28/2007 12:40:00 7.5 0.6 9.1 6.1 7.7 0.6 9.5 6.1 7.9 0.6 9.5 6.1 342 5 341 165 -4.2 0 -3.9 -4.4 02/28/2007 12:50:00 7.6 0.8 9.5 6.1 7.2 1.2 9.9 3.4 8 0.7 9.9 6.1 347 7 349 165 -4 0 -3.7 -4.4 02/28/2007 13:00:00 8.1 0.6 9.5 6.5 7.9 0.9 9.5 4.9 8.1 0.6 9.9 6.1 345 7 346 165 -3.9 0 -3.5 -4.2 02/28/2007 13:10:00 7.5 0.7 9.9 5.7 6.4 1.3 9.9 3.8 7.8 0.7 9.9 6.5 353 5 359 165 -3.7 0 -3.5 -3.9 02/28/2007 13:20:00 7.9 0.8 10.7 6.1 6.5 1.5 9.9 3.4 8.2 0.8 10.3 6.1 354 9 347 165 -3.7 0 -3.5 -3.7 02/28/2007 13:30:00 8 1.1 12.2 4.9 7.1 1.7 12.2 3.8 8.2 1.2 12.2 4.2 351 9 350 165 -3.7 0 -3.5 -3.9 02/28/2007 13:40:00 9.3 1 11.8 7.2 9.3 1.4 12.6 5.3 9.3 1.2 13 5.3 344 6 343 165 -3.8 0 -3.5 -3.9 02/28/2007 13:50:00 9.2 1 12.2 6.8 9 1.5 12.6 3.8 9.5 1.1 13.3 7.2 343 8 348 165 -3.8 0 -3.5 -4.2 02/28/2007 14:00:00 9 0.9 11.5 6.8 8.7 1.3 11.5 4.6 9.2 0.9 11.5 6.8 348 5 334 165 -3.8 0 -3.5 -3.9 02/28/2007 14:10:00 8.3 0.9 10.3 5.7 7.9 1.5 11.1 3.4 8.5 0.9 10.3 6.5 346 8 336 165 -3.7 0 -3.5 -3.9 02/28/2007 14:20:00 8.3 0.9 11.1 6.5 7.4 1.5 10.3 4.2 8.4 1 11.1 6.5 348 10 351 165 -3.7 0 -3.5 -3.9 02/28/2007 14:30:00 8.7 0.9 11.8 6.5 6.1 1.1 9.9 3.4 9 1 11.8 6.8 358 5 10 165 -3.7 0 -3.3 -3.9 02/28/2007 14:40:00 8.7 0.9 11.5 6.5 7.8 1.7 11.8 3.8 8.7 1 11.5 5.7 350 9 347 165 -3.9 0 -3.5 -4.2 02/28/2007 14:50:00 8.4 1 11.1 5.7 8.3 1.1 11.1 4.6 8.4 1 10.7 6.1 340 9 330 165 -4.2 0.1 -3.9 -4.4 02/28/2007 15:00:00 7.3 0.9 10.3 4.2 7.1 1 9.9 4.2 7.1 0.8 8.8 3.4 337 11 340 165 -4.1 0 -3.9 -4.4 02/28/2007 15:10:00 8.2 0.8 9.9 5.3 8 1 9.9 4.6 8.1 0.8 10.3 6.1 338 9 328 165 -4.1 0.1 -3.9 -4.4 02/28/2007 15:20:00 8.1 0.8 9.9 5.7 7.5 1.4 10.3 3.8 8 0.8 10.7 6.5 340 13 341 165 -4 0.1 -3.7 -4.4 02/28/2007 15:30:00 8.1 1.2 11.1 4.9 7.8 1.6 11.5 3.4 8 1.2 11.5 4.6 340 11 348 165 -4.3 0 -4.2 -4.4 02/28/2007 15:40:00 8.2 0.5 9.5 6.5 8.1 0.5 9.5 5.7 8.2 0.6 9.9 6.1 329 8 320 165 -4.3 0 -4.2 -4.6 02/28/2007 15:50:00 8.9 1.1 11.5 6.1 8.8 1.2 11.5 5.7 9 1.2 12.2 6.1 339 8 338 165 -4.5 0 -4.4 -4.6 02/28/2007 16:00:00 7.6 1 10.7 5.3 7.6 1 10.3 4.6 7.6 1 11.1 5.3 334 11 349 165 -4.6 0 -4.4 -4.6 02/28/2007 16:10:00 6.5 1.1 9.1 3.8 6.5 1 9.5 4.2 6.5 1 10.7 3.8 330 9 338 165 -4.7 0 -4.4 -4.8 02/28/2007 16:20:00 8 1.3 11.8 5.3 7.6 1.6 11.8 3.4 8.1 1.4 12.2 4.9 338 14 352 165 -4.8 0 -4.6 -5 02/28/2007 16:30:00 9.1 1.3 13.3 6.1 8.2 2.1 12.6 3.8 9.4 1.4 12.2 6.5 350 10 351 165 -4.8 0 -4.6 -5 02/28/2007 16:40:00 9.1 1.2 12.2 4.6 8.4 1.5 11.1 4.6 9.2 1.2 12.2 5.7 343 12 360 165 -4.8 0 -4.6 -5 02/28/2007 16:50:00 8.3 1.4 15.3 5.3 7.5 1.9 16.1 3.8 8.5 1.5 14.9 4.9 348 10 344 165 -5 0 -4.6 -5.3 02/28/2007 17:00:00 8.8 1.2 13 6.5 8.8 1.2 12.6 6.5 8.9 1.1 12.6 6.5 334 9 317 165 -5.1 0.1 -5 -5.3 02/28/2007 17:10:00 8.7 1.5 12.6 4.9 8.6 1.5 12.6 4.2 8.4 1.5 12.6 4.6 333 12 344 165 -5.2 0 -4.8 -5.5 02/28/2007 17:20:00 7 1.4 11.1 4.2 6.8 1.4 11.1 3.4 7.1 1.4 11.5 4.2 332 11 328 165 -4.9 0 -4.6 -5 02/28/2007 17:30:00 8 1.7 13.3 4.9 7.5 1.8 12.6 3.4 8 1.8 13.7 4.2 338 15 357 165 -4.9 0 -4.6 -5.3 02/28/2007 17:40:00 8.1 1.9 13 4.2 7.9 2.1 13 3 8 2.1 13.3 3 337 14 343 165 -5.2 0.1 -5 -5.3 02/28/2007 17:50:00 8.2 1.1 11.5 5.3 8 1.2 11.1 4.6 8 1.2 11.5 4.9 334 12 321 165 -5.5 0.1 -5 -5.7 02/28/2007 18:00:00 7.8 1.6 13.3 4.2 7.6 1.5 13 3.8 7.4 1.7 13 4.2 333 14 332 165 -5.9 0 -5.7 -6.1 02/28/2007 18:10:00 6.8 2.3 13.3 2.6 6.5 2.1 13.3 2.6 6.5 2.3 14.1 2.6 331 16 315 165 -5.9 0 -5.7 -6.1 02/28/2007 18:20:00 7.8 2.3 14.9 3 7.5 2.2 15.3 2.3 7.7 2.2 14.9 3.4 335 18 358 165 -5.9 0 -5.7 -6.1 02/28/2007 18:30:00 9.7 2.1 14.5 4.9 9.1 2.2 14.9 3.8 9.7 2.4 14.9 4.2 338 17 343 165 -6.1 0 -5.7 -6.4 02/28/2007 18:40:00 9.5 2.4 14.5 2.6 9.2 2.4 14.1 3 9.5 2.3 14.5 3 335 14 336 165 -6.4 0 -6.1 -6.6 02/28/2007 18:50:00 9.5 1.8 14.9 5.7 9 1.8 14.9 5.3 9.5 1.9 14.9 4.9 337 13 344 165 -6.5 0 -6.1 -6.6 02/28/2007 19:00:00 11.1 2.3 17.2 5.3 11 2.3 17.2 5.3 10.8 2.4 16.1 4.6 335 9 336 165 -6.5 0 -6.4 -6.6 02/28/2007 19:10:00 10.3 2.4 16.4 5.3 10.2 2.4 16.4 4.9 10.1 2.6 16.8 4.2 330 13 336 165 -6.6 0 -6.4 -6.8 02/28/2007 19:20:00 8.7 1.7 13.3 4.6 8.6 1.7 13.7 3.4 8.5 1.8 13.7 4.9 332 12 349 165 -6.7 0 -6.6 -6.8 02/28/2007 19:30:00 10 2.3 16.8 4.9 9.8 2.3 16.8 4.2 9.8 2.6 17.2 4.6 326 16 333 165 -6.7 0 -6.6 -6.8 02/28/2007 19:40:00 7.4 1.7 12.2 3.4 7.3 1.7 12.2 3.4 6.8 1.7 12.2 2.3 313 15 344 165 -6.7 0 -6.6 -6.8 02/28/2007 19:50:00 10.4 1.6 15.6 6.5 10.2 1.7 15.6 5.7 10.2 1.8 16.1 6.8 328 13 336 165 -6.7 0 -6.6 -6.8 02/28/2007 20:00:00 11.6 1.9 17.2 6.5 11.3 2.2 16.8 6.1 11 1.9 15.6 6.5 330 15 325 165 -6.8 0 -6.6 -7 02/28/2007 20:10:00 11.2 2.1 17.9 6.8 10.8 2.2 17.6 5.7 10.7 2.2 18.3 6.1 335 13 344 165 -7.1 0 -6.8 -7.2 02/28/2007 20:20:00 11.1 2.7 16.1 4.2 10.9 2.8 16.4 3.4 10.1 2.7 17.2 3 336 10 346 165 -7.2 0 -7 -7.2 02/28/2007 20:30:00 12.8 1.8 17.2 7.2 12.5 1.9 17.9 6.5 11.5 2.1 17.6 6.5 336 11 328 165 -7.2 0 -7 -7.4 02/28/2007 20:40:00 12 2.1 16.8 6.1 11.9 2.2 16.8 5.7 10.7 2.1 15.6 4.9 336 10 344 165 -7.2 0 -7 -7.4 02/28/2007 20:50:00 12.1 2.1 16.8 5.3 11.9 2.2 16.4 5.7 11.2 2.5 17.9 4.6 335 12 332 165 -7.4 0 -7.2 -7.4 02/28/2007 21:00:00 12.5 1.8 17.9 8 12.3 1.9 17.9 7.6 12.2 1.8 16.8 7.2 334 10 330 165 -7.3 0 -7.2 -7.6 02/28/2007 21:10:00 13.2 1.7 17.6 8.8 13.1 1.8 18.3 8.8 13 1.8 19.5 9.1 331 10 336 165 -7.2 0 -7 -7.4 02/28/2007 21:20:00 13.7 1.9 19.9 8.8 13.5 2.1 20.6 7.6 13.7 2.1 19.5 8.4 330 12 344 165 -7.2 0 -7 -7.4 02/28/2007 21:30:00 14 2 19.1 9.1 13.8 2 18.7 9.1 13.7 2.2 18.3 6.8 329 11 348 165 -7.3 0 -7 -7.4 02/28/2007 21:40:00 14.7 1.8 20.2 9.9 14.5 1.7 20.6 10.3 14.7 1.8 19.1 11.1 330 12 334 165 -7.4 0 -7.2 -7.6 02/28/2007 21:50:00 14.8 1.8 19.5 11.5 14.7 1.9 20.2 10.7 14.7 2.1 19.9 9.1 329 8 330 165 -7.5 0 -7.2 -7.6 02/28/2007 22:00:00 13.2 2 17.2 8 13 2 17.6 7.6 13 2 17.2 8.4 334 9 344 165 -7.5 0 -7.2 -7.6 02/28/2007 22:10:00 13 2.1 18.3 8 12.9 2.3 18.3 6.1 12.7 2.2 17.9 5.7 337 13 333 165 -7.6 0 -7.4 -7.6 02/28/2007 22:20:00 13.3 2 17.9 7.2 13.2 2.1 17.9 6.5 13 2.1 17.9 7.2 331 15 342 165 -7.5 0 -7.4 -7.6 02/28/2007 22:30:00 14 2 19.5 8.4 13.7 2.1 19.1 7.6 13.5 2.1 19.1 5.3 330 15 319 165 -7.6 0 -7.4 -7.9 02/28/2007 22:40:00 15.9 1.8 20.2 10.3 15.9 2 20.2 10.3 15.9 2.3 21 9.1 335 10 336 165 -7.5 0.1 -7.2 -7.9 02/28/2007 22:50:00 15.8 2.4 22.1 10.3 15.7 2.4 22.1 10.3 15.9 2.3 21.8 10.7 332 9 325 165 -7.5 0 -7.4 -7.6 02/28/2007 23:00:00 15.1 1.7 20.6 9.1 14.7 1.8 19.9 9.5 14.9 1.8 20.6 9.9 333 13 334 165 -7.6 0 -7.4 -7.9 02/28/2007 23:10:00 14.6 1.7 19.5 10.7 14.5 1.7 19.1 10.7 14.6 1.9 19.1 9.1 331 11 342 165 -7.6 0 -7.4 -7.9 02/28/2007 23:20:00 18.1 1.7 23.7 13.7 18 2 23.3 11.1 18 1.9 21.8 12.6 333 10 333 165 -7.6 0 -7.4 -8.1 02/28/2007 23:30:00 16.1 2.5 21.4 10.7 15.9 2.5 21 10.3 15.6 2.9 21.4 9.5 325 15 331 165 -7.7 0 -7.4 -7.9 02/28/2007 23:40:00 15.2 1.7 19.5 10.7 15.1 1.7 19.1 10.7 15.1 1.8 19.5 10.7 330 9 339 165 -7.7 0 -7.4 -8.1 02/28/2007 23:50:00 15.3 2 21.8 9.5 15.1 2.3 21.8 9.1 15 2.2 22.1 9.9 337 10 338 165 -7.8 0 -7.6 -8.1 03/01/2007 00:00:00 16.2 2 21.8 11.1 16.2 2.1 21.8 10.7 16.1 2.1 21.8 10.7 331 13 338 165 -7.7 0 -7.4 -8.1 03/01/2007 00:10:00 15.7 1.7 21.8 9.9 15.5 1.7 21 10.7 15.8 1.6 21 11.8 325 11 323 165 -7.7 0 -7.4 -8.1 03/01/2007 00:20:00 20.7 2.5 27.1 15.3 20.5 2.5 27.1 14.9 20.6 2.7 26.8 13.7 333 8 339 165 -7.8 0 -7.4 -8.1 03/01/2007 00:30:00 19 2.3 26.8 12.6 18.8 2.3 27.1 11.1 18.8 2.5 27.1 10.7 331 8 326 165 -7.6 0 -7.4 -7.9 03/01/2007 00:40:00 18.7 2.6 26.8 9.5 18.5 2.6 27.1 9.9 18.8 2.8 26 9.1 332 11 328 165 -7.5 0 -7.4 -7.6 03/01/2007 00:50:00 18.8 2.5 24.4 12.2 18.7 2.5 24 11.8 18.5 2.5 24.8 12.2 333 9 324 165 -7.6 0 -7.4 -7.6 03/01/2007 01:00:00 18.4 2.4 24.8 10.3 18.2 2.6 24.8 11.1 18.3 2.6 24.4 9.9 332 9 331 165 -7.5 0 -7.2 -7.6 03/01/2007 01:10:00 14.2 2.6 19.9 7.6 13.9 2.7 20.2 7.2 14.1 2.7 20.6 6.8 335 12 328 165 -7.6 0 -7.4 -7.9 03/01/2007 01:20:00 13.6 2.4 20.2 7.6 13.4 2.5 20.6 6.8 13 2.4 20.2 8.4 329 11 330 165 -7.8 0 -7.6 -8.1 03/01/2007 01:30:00 11.2 2.2 17.6 7.2 11.1 2.2 17.2 7.2 10.5 2.2 16.8 5.3 325 14 318 165 -7.9 0 -7.6 -8.1 03/01/2007 01:40:00 8.5 1.5 12.6 4.6 7.9 1.7 13 4.2 8 1.4 11.5 4.6 339 17 312 165 -8.1 0 -7.9 -8.3 03/01/2007 01:50:00 12.6 2.5 21 7.2 12.5 2.6 20.6 6.8 12.2 2.8 20.6 6.8 328 12 332 165 -7.9 0 -7.6 -8.1 03/01/2007 02:00:00 13.6 2.7 21.4 6.8 13.3 2.7 21.8 6.5 13 2.6 22.6 7.2 325 10 332 165 -7.8 0 -7.6 -8.1 03/01/2007 02:10:00 12 3.3 18.7 6.5 11.7 3.3 17.9 5.7 11.1 3.5 17.9 5.3 325 17 336 165 -7.9 0 -7.6 -8.1 03/01/2007 02:20:00 13.8 3.1 21.4 8.8 13.6 3.1 21 6.1 13.2 3.1 22.6 7.6 325 13 322 165 -8 0 -7.6 -8.1 03/01/2007 02:30:00 8.9 2.2 16.1 4.9 8.6 2.3 15.6 3.8 8.4 2.2 16.4 3.8 346 28 25 165 -8.1 0 -7.6 -8.3 03/01/2007 02:40:00 12.4 3.2 21.4 5.7 10.6 3.1 20.6 5.3 12.1 3.2 20.2 5.7 1 18 15 165 -8.1 0 -7.9 -8.3 03/01/2007 02:50:00 13.7 2.6 21.4 7.6 11.4 2.4 17.9 4.9 13.3 2.8 20.6 4.6 359 16 3 165 -8.1 0 -7.9 -8.3 03/01/2007 03:00:00 13.5 2.4 22.9 9.1 11.5 2.8 22.9 6.5 13.4 2.4 24 9.1 6 15 6 165 -8.1 0 -7.9 -8.5 03/01/2007 03:10:00 16.4 2.7 23.3 9.5 14.1 3.1 22.1 6.8 16.6 2.8 23.3 9.1 356 14 3 165 -8 0 -7.9 -8.3 03/01/2007 03:20:00 18.1 2.7 24.8 12.6 15.3 3.1 22.9 8.8 18 2.9 26.3 11.8 352 10 7 165 -8.1 0 -7.9 -8.3 03/01/2007 03:30:00 16 2.6 24 10.7 14.6 2.9 23.7 8.4 16.2 2.7 23.7 10.3 349 13 3 165 -8 0 -7.9 -8.3 03/01/2007 03:40:00 14.6 2.1 19.1 9.1 11.9 2.2 17.9 7.2 14.6 2.2 20.2 9.5 352 12 7 165 -8.1 0 -8.1 -8.3 03/01/2007 03:50:00 16.1 2.8 25.2 9.1 14.3 2.9 22.6 8.8 16 2.9 25.2 9.1 351 15 3 165 -8 0 -7.6 -8.1 03/01/2007 04:00:00 14 2.9 22.6 8.4 12.9 2.6 23.3 7.2 13.9 2.9 23.3 8.4 344 13 349 165 -7.9 0.1 -7.6 -8.1 03/01/2007 04:10:00 12 2.1 21 6.5 11.2 2.1 20.6 6.1 12 2.2 19.5 7.6 343 17 18 165 -8 0 -7.6 -8.3 03/01/2007 04:20:00 14.3 2.3 20.2 9.1 11.7 2.5 19.9 5.7 14.1 2.3 21 8.4 358 11 347 165 -7.9 0.1 -7.6 -8.1 03/01/2007 04:30:00 11.6 2.6 17.9 6.5 10.1 2.3 17.2 5.3 11.3 2.7 18.7 5.7 351 14 343 165 -8 0 -7.6 -8.1 03/01/2007 04:40:00 10.6 1.8 17.2 6.1 9.5 1.7 15.6 5.3 10.4 1.8 16.4 5.7 346 15 358 165 -8 0 -7.9 -8.1 03/01/2007 04:50:00 15 3.1 21.8 5.7 12.7 3.2 21.4 5.3 15 3.2 22.1 4.6 360 15 13 165 -7.7 0 -7.4 -8.1 03/01/2007 05:00:00 15.4 2.4 21.8 9.1 12.5 2.6 20.2 6.5 15.4 2.6 22.1 7.2 0 13 360 165 -7.8 0 -7.6 -8.1 03/01/2007 05:10:00 11.3 2.1 16.4 4.9 10.2 2.3 15.3 4.9 10.9 2.1 16.4 4.2 355 21 359 165 -8.2 0 -7.9 -8.5 03/01/2007 05:20:00 13.1 3.2 24 5.7 11 3.3 24.4 4.9 12.7 3.5 22.1 6.1 360 14 341 165 -8.3 0.1 -8.1 -8.5 03/01/2007 05:30:00 16.9 2.9 24.4 8.4 14.5 3.2 23.3 5.7 16.6 3.2 24.4 8.4 354 12 356 165 -8 0 -7.9 -8.3 03/01/2007 05:40:00 17.6 2.6 27.1 11.5 15 2.8 22.1 8.8 17.6 2.9 26.8 11.5 356 14 1 165 -8.1 0 -7.9 -8.3 03/01/2007 05:50:00 18.5 2.7 26.8 11.5 15.1 3.2 24.8 8.8 18.4 2.9 26.8 12.2 1 12 358 165 -8.2 0 -8.1 -8.5 03/01/2007 06:00:00 18.5 2.9 26.3 9.9 15 3.5 25.2 8 18.8 3.1 26.3 11.8 6 12 23 165 -8.2 0 -8.1 -8.5 03/01/2007 06:10:00 14.3 2.8 21.4 6.5 12.1 2.7 18.3 6.5 14.3 2.9 20.6 5.7 352 15 7 165 -8.3 0 -8.1 -8.5 03/01/2007 06:20:00 11.3 2 17.9 7.6 10.7 2.3 18.7 5.7 10.7 2.2 16.1 5.7 336 21 286 165 -8.7 0.1 -8.3 -8.9 03/01/2007 06:30:00 11.2 2 16.4 6.1 10.9 2.2 16.4 5.7 10.1 2.1 14.9 5.7 331 17 312 165 -9 0.1 -8.7 -9.1 03/01/2007 06:40:00 12.6 2.3 18.3 5.7 12.3 2.4 18.3 4.9 11.9 2.4 17.2 3.8 332 13 331 165 -9 0 -8.9 -9.1 03/01/2007 06:50:00 17.3 3.8 27.1 9.1 17 3.8 26.3 8.4 16.5 3.6 26.3 8 327 11 318 165 -8.9 0 -8.5 -9.1 03/01/2007 07:00:00 16.8 4.1 27.1 7.6 16.5 4.1 26.8 7.2 15.6 4.3 27.5 5.3 321 15 337 165 -8.9 0 -8.7 -8.9 03/01/2007 07:10:00 13.2 2.7 20.6 6.8 13.1 2.6 20.6 6.5 12.3 2.7 18.3 5.7 326 15 342 165 -8.9 0 -8.7 -9.1 03/01/2007 07:20:00 14.5 4.1 29.4 6.1 14.2 4.1 29.1 6.5 13.7 4.3 28.7 4.2 323 17 328 165 -8.9 0.1 -8.7 -9.1 03/01/2007 07:30:00 17.9 2.9 27.1 10.7 17.7 3.1 28.3 9.9 17.2 3.2 29.4 9.5 325 12 306 165 -8.8 0 -8.5 -9.1 03/01/2007 07:40:00 20.3 3.5 29.4 11.1 20.1 3.5 29.1 11.1 19.4 3.8 29.8 9.9 325 11 323 165 -9 0.1 -8.7 -9.1 03/01/2007 07:50:00 20.6 3.2 30.6 10.3 20.2 3.5 30.6 8.4 19.9 3.2 28.3 11.8 326 13 310 165 -9.1 0 -8.9 -9.1 03/01/2007 08:00:00 19.3 3.5 30.6 11.5 19 3.3 30.2 11.5 18.3 3.6 29.8 11.1 325 12 332 165 -9.2 0 -8.9 -9.5 03/01/2007 08:10:00 19.4 3.2 30.2 12.2 19 3.2 29.4 10.3 18.3 3.2 28.3 13 329 13 298 165 -9.6 0.1 -9.3 -9.7 03/01/2007 08:20:00 23.9 3.3 34.4 14.5 23.6 3.3 33.6 14.5 23 3.2 31.3 12.6 326 12 326 165 -9.4 0 -9.3 -10 03/01/2007 08:30:00 22.3 3.5 35.2 13.3 22.1 3.5 35.5 12.6 21.2 3.6 33.6 12.6 328 11 340 165 -9.1 0.1 -8.9 -9.7 03/01/2007 08:40:00 26.7 3.5 35.2 16.8 26.5 3.5 35.2 16.4 26.3 3.5 34.8 15.3 330 9 339 165 -9.1 0 -8.9 -9.3 03/01/2007 08:50:00 26.6 3.8 35.5 17.9 26 3.8 34.8 17.2 26.3 3.8 36.3 17.6 330 12 323 165 -9.1 0 -8.9 -9.3 03/01/2007 09:00:00 27.1 4.5 38.2 15.6 26.8 4.5 37.8 15.6 26.6 4.5 38.2 16.1 330 11 323 165 -8.9 0 -8.5 -9.1 03/01/2007 09:10:00 26.4 4 38.6 16.8 26.1 4 38.2 15.3 25.7 4.3 37.8 13.7 331 10 332 165 -8.8 0 -8.5 -8.9 03/01/2007 09:20:00 25.6 4.7 38.6 11.8 25.2 4.7 37.8 11.1 24.9 4.7 37.5 11.8 332 11 323 165 -8.8 0 -8.5 -8.9 03/01/2007 09:30:00 25.7 4.1 37.5 14.9 25.1 4.3 37.1 15.6 25.5 4.1 38.2 16.4 327 13 329 165 -8.8 0 -8.5 -9.1 03/01/2007 09:40:00 24.5 3.3 33.2 14.1 24.4 3.3 32.9 14.5 24.4 3.3 33.2 14.9 329 10 320 165 -8.7 0 -8.5 -8.9 03/01/2007 09:50:00 21.2 3.2 30.9 12.6 21 3.2 31.3 11.8 20.5 3.6 29.4 8.4 325 12 302 165 -8.6 0.1 -8.3 -8.9 03/01/2007 10:00:00 20.6 3.3 30.2 13 20.2 3.6 30.2 9.1 20.1 3.5 28.3 11.1 329 15 303 165 -8.5 0.1 -8.3 -8.9 03/01/2007 10:10:00 21.6 3.6 30.9 12.6 21.3 3.8 30.2 11.5 21 4.1 29.8 10.3 326 12 319 165 -8.5 0 -8.3 -8.7 03/01/2007 10:20:00 16.4 3.2 26.3 6.1 16.2 3.3 26.8 6.1 15.3 3.3 25.2 4.6 323 15 311 165 -8.3 0.2 -7.9 -8.7 03/01/2007 10:30:00 15.6 2.7 22.9 9.1 15.2 2.9 22.9 7.6 14.6 2.4 23.3 8 329 19 297 165 -8 0.1 -7.6 -8.1 03/01/2007 10:40:00 17.7 4 29.4 8.8 17.2 4.1 29.1 8 17 3.8 29.8 8 329 15 326 165 -8.1 0 -7.6 -8.5 03/01/2007 10:50:00 18.4 3.5 28.3 9.5 18.1 3.5 28.3 9.1 17.4 3.6 27.5 8.8 328 13 326 165 -8.2 0.1 -8.1 -8.5 03/01/2007 11:00:00 18.9 4 28.7 10.3 18.4 4.3 29.1 8.8 17.8 4.1 27.9 8 327 15 310 165 -8.2 0.1 -7.9 -8.5 03/01/2007 11:10:00 21.4 3.1 30.2 14.9 21 3.2 30.2 13 20.7 3.5 30.6 12.6 330 11 333 165 -8.3 0 -8.1 -8.5 03/01/2007 11:20:00 18.4 3.3 28.3 9.9 18.2 3.5 27.5 8 17.8 3.5 26.8 8.8 326 13 322 165 -8.2 0.1 -7.9 -8.5 03/01/2007 11:30:00 19.7 3.5 28.7 10.3 19.5 3.5 29.1 9.9 19.2 4 30.9 8.8 324 12 302 165 -8.1 0 -7.9 -8.3 03/01/2007 11:40:00 20.8 3.2 33.6 12.6 20.5 3.3 33.2 11.1 19.8 3.3 29.1 12.2 322 12 290 165 -8.1 0.1 -7.6 -8.5 03/01/2007 11:50:00 18 2.7 27.5 11.1 17.7 2.7 27.1 10.7 17.4 2.9 27.1 10.3 325 13 316 165 -7.9 0.1 -7.4 -8.3 03/01/2007 12:00:00 19.7 3.2 29.8 11.1 19.4 3.2 30.2 10.7 18.9 3.3 28.7 9.1 320 10 326 165 -8 0.1 -7.6 -8.1 03/01/2007 12:10:00 17.7 3.1 27.1 8.8 17.2 3.5 26.8 8 16.8 3.2 26 6.8 331 13 320 165 -7.8 0.2 -7.4 -8.1 03/01/2007 12:20:00 18.6 3.1 26.3 11.8 18.3 3.1 26.8 11.1 17.6 3.3 24.4 8.8 320 12 297 165 -7.8 0 -7.4 -8.1 03/01/2007 12:30:00 18.7 3.1 27.9 11.8 18.5 3.1 28.7 11.8 18 3.2 28.3 10.7 322 10 341 165 -7.9 0.1 -7.6 -8.1 03/01/2007 12:40:00 15.5 2.8 24 9.5 14.6 2.9 22.6 7.2 15.1 2.6 23.3 9.9 338 17 7 165 -7.4 0.1 -6.8 -8.1 03/01/2007 12:50:00 17 3.6 29.8 7.6 16.7 3.8 30.2 7.2 16.2 3.5 31.8 8.8 326 15 327 165 -7.4 0.1 -7 -7.6 03/01/2007 13:00:00 17.7 2.6 25.2 11.8 16.8 2.9 25.6 9.9 17.2 2.4 24 11.5 331 18 307 165 -7.4 0.2 -7.2 -7.9 03/01/2007 13:10:00 16.6 3.3 30.6 7.2 16.3 3.3 29.1 5.7 15.9 3.1 23.7 8.8 323 11 296 165 -7.6 0.1 -7.2 -8.1 03/01/2007 13:20:00 13.7 2.9 21.4 5.7 13.3 2.9 21.4 5.3 13.1 2.9 22.9 4.2 332 21 31 165 -7.2 0.1 -6.8 -7.4 03/01/2007 13:30:00 12.1 2.3 19.9 6.1 11.7 2.3 19.9 6.1 11.6 2.5 18.3 5.3 331 17 334 165 -6.9 0.1 -6.6 -7.2 03/01/2007 13:40:00 12.5 2.8 20.6 5.3 12.1 2.9 20.2 4.6 12.1 2.8 21.4 4.6 332 17 327 165 -7.1 0.1 -6.6 -7.2 03/01/2007 13:50:00 15.5 4.5 28.7 8 15.1 4.7 28.7 6.8 15.4 4.5 29.1 7.2 331 16 323 165 -7.2 0.3 -6.8 -7.6 03/01/2007 14:00:00 17.7 3.5 26.8 8.8 17.5 3.5 26.3 8.8 17.1 3.3 26.8 9.9 325 11 335 165 -7.5 0.1 -7.2 -7.9 03/01/2007 14:10:00 17.3 3.5 29.4 11.1 17.1 3.5 28.7 10.3 16.9 3.3 29.8 10.7 327 11 329 165 -7.3 0.1 -6.8 -7.4 03/01/2007 14:20:00 17.5 2.9 26.3 7.6 17.3 2.9 26.8 7.6 16.6 3.2 24.4 8 322 12 329 165 -7.3 0.1 -6.8 -7.4 03/01/2007 14:30:00 18 3.2 25.6 9.1 17.6 3.3 24.8 9.5 17.8 3.5 26 7.6 328 13 325 165 -7.3 0 -7 -7.4 03/01/2007 14:40:00 19.7 3.3 27.5 10.3 19.3 3.5 27.5 9.9 19 3.3 26.3 10.7 327 12 328 165 -7.2 0 -6.8 -7.4 03/01/2007 14:50:00 17.3 3.3 26.8 10.3 17.1 3.3 26.3 8.8 16.5 3.5 26 8.4 327 15 336 165 -7 0.1 -6.6 -7.2 03/01/2007 15:00:00 16.8 3.6 26 9.9 16.6 3.5 27.1 9.5 16.4 4 27.5 8.4 325 14 346 165 -6.8 0 -6.6 -7 03/01/2007 15:10:00 17.1 3.6 26 8 16.9 3.6 26 7.6 16.2 4 26.8 7.2 321 20 318 165 -6.8 0.1 -6.6 -7 03/01/2007 15:20:00 13.3 3.5 24.8 6.5 13.2 3.5 24.8 6.5 12.5 3.6 24.8 6.1 322 16 313 165 -6.5 0.2 -6.1 -7 03/01/2007 15:30:00 10.9 3.2 18.7 1.5 10.7 3.2 19.5 1.9 10.2 2.8 17.2 2.6 321 22 327 165 -6.4 0.2 -5.9 -6.8 03/01/2007 15:40:00 15 4.1 24.8 4.6 14.9 4.1 24.8 4.2 13.9 4.1 26 4.9 320 16 319 165 -6.6 0.1 -6.1 -6.8 03/01/2007 15:50:00 12 2.9 20.6 6.5 11.2 3.1 19.9 5.3 11.5 3.1 22.9 4.9 340 23 329 165 -6.6 0.2 -6.1 -7 03/01/2007 16:00:00 11.7 2.6 22.6 5.7 11.1 2.8 22.6 5.3 11.1 2.4 19.9 6.1 341 20 321 165 -6.3 0.1 -5.9 -6.6 03/01/2007 16:10:00 12.8 2.5 21 6.5 12.5 2.6 20.2 5.7 11.9 2.6 20.2 6.1 323 16 310 165 -6.6 0 -6.4 -6.8 03/01/2007 16:20:00 14 3.5 23.3 6.1 13.3 3.6 23.3 4.9 13.4 3.2 21.8 6.5 338 26 22 165 -6.7 0.1 -6.4 -7 03/01/2007 16:30:00 13.2 2.5 18.7 5.3 11.5 2.8 17.6 4.6 13 2.6 18.7 4.2 352 22 15 165 -6.8 0 -6.6 -7 03/01/2007 16:40:00 13.1 2.6 21.4 6.5 12.4 2.6 19.5 6.1 12.4 2.5 19.5 6.1 341 20 4 165 -6.8 0 -6.6 -6.8 03/01/2007 16:50:00 11.9 2.6 20.6 4.6 10.7 2.6 19.1 5.3 11.5 2.6 21 3.8 353 21 18 165 -6.8 0 -6.6 -7 03/01/2007 17:00:00 12.3 2.8 18.7 3.8 11.5 2.7 18.3 3.8 11.8 2.9 19.1 3 335 23 359 165 -6.9 0 -6.6 -7 03/01/2007 17:10:00 14.2 3.5 24.4 6.1 13.6 3.6 24.8 6.1 13.8 3.3 23.3 5.3 337 17 326 165 -6.9 0 -6.8 -7.2 03/01/2007 17:20:00 14.5 3.2 24.4 4.6 14.1 3.2 24.4 4.2 13.6 3.3 22.6 5.3 326 17 325 165 -7.2 0 -6.8 -7.4 03/01/2007 17:30:00 16.7 3.6 29.4 9.1 16.5 3.6 28.7 8.4 16.4 4 29.8 8 328 15 335 165 -7.4 0.1 -7.2 -7.6 03/01/2007 17:40:00 15.9 3.1 24.8 7.2 15.6 3.1 23.7 6.8 15.1 3.1 22.9 8 332 12 324 165 -7.4 0 -7.2 -7.4 03/01/2007 17:50:00 16.4 3.2 26.8 8 16.1 3.3 26.8 8.4 15.7 3.5 26.8 5.7 327 15 323 165 -7.5 0 -7.2 -7.6 03/01/2007 18:00:00 14.9 4 27.1 6.8 13.8 4 27.1 7.2 14 3.6 25.2 7.6 333 22 292 165 -7.6 0 -7.2 -7.9 03/01/2007 18:10:00 13.7 3.2 24.8 6.1 13.2 3.3 24.8 6.5 12.9 3.1 22.6 7.2 331 17 332 165 -7.9 0 -7.6 -8.1 03/01/2007 18:20:00 15.3 3.1 25.2 6.8 14.9 3.2 24.8 4.9 14.7 3.2 23.7 8 337 22 319 165 -8 0 -7.6 -8.1 03/01/2007 18:30:00 17 3.8 29.1 8.8 16.2 3.8 28.7 8.8 16.4 4.1 28.3 8.8 338 19 347 165 -8 0 -7.9 -8.1 03/01/2007 18:40:00 16 3.5 25.6 9.5 14.6 3.2 23.7 6.8 15.9 3.8 27.9 9.9 346 16 351 165 -8 0 -7.9 -8.1 03/01/2007 18:50:00 16.6 2.3 24.4 10.7 15.1 2.6 23.7 8.4 16.3 2.4 24 9.5 344 21 23 165 -8.1 0 -8.1 -8.3 03/01/2007 19:00:00 15.5 2.5 24 10.3 14.4 2.5 21.8 7.6 15.2 2.5 23.7 9.9 337 19 356 165 -8.2 0 -8.1 -8.3 03/01/2007 19:10:00 15.3 2.8 24.8 7.2 14.8 2.9 25.2 6.5 14.6 2.9 24.4 6.8 333 15 353 165 -8.1 0 -8.1 -8.3 03/01/2007 19:20:00 15.9 2.6 23.3 11.5 14.9 2.7 22.6 9.1 15.5 2.5 23.3 8.4 338 17 3 165 -8.1 0 -7.9 -8.5 03/01/2007 19:30:00 17.3 4.1 28.3 8.8 16.5 4.1 28.3 6.8 16.8 4.1 28.7 7.6 331 18 325 165 -8 0.1 -7.6 -8.3 03/01/2007 19:40:00 18.9 3.2 28.7 11.1 18.4 3.3 28.3 8.8 18.2 3.1 28.7 11.5 332 14 319 165 -8 0 -7.9 -8.1 03/01/2007 19:50:00 17.5 3.3 26.8 10.7 17.2 3.5 26 9.5 16.8 3.2 25.6 10.3 326 14 322 165 -8 0 -7.9 -8.1 03/01/2007 20:00:00 19.9 2.9 27.1 12.6 19.7 2.9 27.9 11.5 19.1 3.1 27.1 10.7 324 12 326 165 -7.9 0 -7.6 -8.1 03/01/2007 20:10:00 19 3.8 30.6 10.7 18.6 4 30.6 9.9 17.8 3.6 29.8 9.1 324 13 311 165 -7.9 0 -7.6 -8.1 03/01/2007 20:20:00 20.1 4.1 31.3 10.7 20 4 30.9 9.9 19.5 4 29.4 9.1 321 15 297 165 -7.7 0 -7.6 -8.1 03/01/2007 20:30:00 19.9 4.3 34.4 11.1 19.8 4.3 33.6 10.7 19.3 4.3 30.9 10.7 322 14 321 165 -7.6 0 -7.4 -8.1 03/01/2007 20:40:00 16.3 4.9 29.1 4.9 15.9 5.1 28.7 4.9 15.7 5.1 27.9 3.4 328 17 305 165 -7.6 0 -7.4 -8.1 03/01/2007 20:50:00 15.7 3.2 27.9 9.5 15.1 3.5 28.3 7.2 14.9 3.5 27.5 8.4 335 21 311 165 -7.8 0 -7.6 -8.1 03/01/2007 21:00:00 17.9 3.3 28.3 9.9 17.4 3.6 28.3 8.8 17.3 3.3 28.7 10.3 331 18 331 165 -7.8 0 -7.4 -8.1 03/01/2007 21:10:00 16.7 3.5 26.8 9.9 16.3 3.6 27.1 9.5 16 3.5 27.1 7.6 325 15 318 165 -7.6 0 -7.4 -7.9 03/01/2007 21:20:00 16.3 3.2 25.6 10.3 15.9 3.2 25.2 9.5 15.8 3.3 26 8.8 329 15 307 165 -7.8 0 -7.6 -8.1 03/01/2007 21:30:00 17 3.3 25.6 9.1 16.5 3.8 26 8 16.4 3.2 24.8 8 331 15 328 165 -7.9 0 -7.6 -8.1 03/01/2007 21:40:00 18.3 3.3 26.8 11.5 18.1 3.3 26.3 10.7 17.6 3.5 26.8 8.4 323 13 297 165 -7.8 0 -7.4 -8.1 03/01/2007 21:50:00 19 4.1 31.3 10.3 18.8 4 30.6 10.3 18.4 4.3 30.2 6.8 322 11 319 165 -8 0 -7.6 -8.1 03/01/2007 22:00:00 14 3.5 24.8 6.8 13.6 3.3 24 6.5 12.9 3.6 24.4 6.5 330 20 321 165 -8 0.1 -7.6 -8.3 03/01/2007 22:10:00 15.3 3.6 23.3 6.1 14.5 3.6 22.6 6.5 14.9 3.8 24 6.8 341 22 8 165 -8 0 -7.9 -8.3 03/01/2007 22:20:00 16.6 3.3 24.4 4.9 15.9 3.3 23.7 4.9 15.9 3.2 24 3 336 23 326 165 -8 0 -7.9 -8.3 03/01/2007 22:30:00 16 3.6 27.9 7.6 15.7 3.6 27.5 7.2 15.7 4 28.7 7.2 328 15 316 165 -8 0 -7.6 -8.1 03/01/2007 22:40:00 19.9 4.7 30.9 7.6 19.5 4.7 30.2 7.2 18.8 4.7 30.9 4.2 325 17 338 165 -8 0 -7.6 -8.1 03/01/2007 22:50:00 18.4 4 27.1 10.3 18.1 4.1 26.8 9.1 18 4.1 27.5 6.1 327 15 319 165 -8 0 -7.6 -8.1 03/01/2007 23:00:00 16.8 4.1 28.7 8.8 15.8 4.3 28.7 7.6 16.1 4.1 26.8 6.8 334 20 334 165 -8 0 -7.9 -8.3 03/01/2007 23:10:00 15.3 3.5 27.1 7.6 13.7 3.5 26 6.8 14.9 3.6 26.3 7.2 350 19 19 165 -8 0 -7.9 -8.3 03/01/2007 23:20:00 20.2 4.5 32.1 10.3 19.5 4.5 31.8 8.8 19.5 4.7 32.9 9.9 333 20 315 165 -7.9 0 -7.6 -8.1 03/01/2007 23:30:00 21.4 4.1 32.1 11.1 21.1 4.1 32.1 10.7 20.4 4.1 33.2 11.8 327 15 331 165 -8 0 -7.6 -8.3 03/01/2007 23:40:00 21.2 4.7 34.8 11.5 20.9 4.7 34.4 10.7 19.9 4.7 33.6 9.5 320 17 317 165 -8 0 -7.6 -8.3 03/01/2007 23:50:00 21.4 3.5 30.2 13.3 21.1 3.5 30.9 14.1 20.6 3.5 29.1 11.8 324 14 290 165 -8 0 -7.6 -8.1 03/02/2007 00:00:00 20.3 3.5 28.7 11.5 20 3.5 28.7 10.7 19.6 3.5 30.2 11.5 327 14 321 165 -8 0 -7.6 -8.1 03/02/2007 00:10:00 19.8 3.6 31.3 8.4 19.6 3.8 31.3 9.1 19 4 30.9 5.7 320 15 321 165 -8 0 -7.6 -8.1 03/02/2007 00:20:00 21.6 3.8 31.8 7.2 21.4 3.8 32.1 6.8 21 4.1 31.3 10.3 326 13 317 165 -8 0 -7.6 -8.3 03/02/2007 00:30:00 20.3 3.2 30.9 10.3 20 3.3 30.9 9.9 19.7 3.3 28.3 10.7 323 12 305 165 -8 0 -7.9 -8.1 03/02/2007 00:40:00 21.1 3.3 31.3 12.6 20.6 3.6 30.6 11.8 20.3 3.5 28.7 12.2 324 16 322 165 -8 0 -7.9 -8.3 03/02/2007 00:50:00 19.2 3.8 28.7 11.1 19 3.8 28.7 10.3 18.5 4 28.7 9.9 320 15 317 165 -8.1 0 -7.9 -8.3 03/02/2007 01:00:00 18.9 2.9 27.9 12.2 18.7 2.8 27.1 12.2 17.9 3.1 26.8 11.1 323 12 336 165 -8.1 0 -7.9 -8.3 03/02/2007 01:10:00 20.8 4 33.2 11.8 20.6 4 33.2 11.5 19.9 4 32.4 10.7 322 12 331 165 -8.1 0 -8.1 -8.3 03/02/2007 01:20:00 20.1 3.8 29.1 10.7 19.8 3.8 29.1 9.9 19.7 3.8 30.9 7.6 322 15 310 165 -8.1 0 -8.1 -8.3 03/02/2007 01:30:00 18.4 4 28.3 8.8 18.2 3.8 27.5 8.8 17.7 4 27.9 7.6 321 13 325 165 -8.3 0 -8.1 -8.5 03/02/2007 01:40:00 20.8 3.8 30.2 11.1 20.7 3.8 29.1 9.5 20.3 4 28.7 11.1 324 11 334 165 -8.3 0 -8.1 -8.5 03/02/2007 01:50:00 18.7 3.5 29.1 11.5 18.5 3.6 29.4 10.3 18.4 3.6 29.1 10.3 325 12 312 165 -8.4 0.1 -8.1 -8.5 03/02/2007 02:00:00 18.4 3.1 27.9 11.1 18.2 3.1 27.9 8.8 18 3.1 28.7 11.5 323 12 325 165 -8.3 0 -8.1 -8.5 03/02/2007 02:10:00 16 2.9 27.5 8.8 15.6 2.9 27.5 9.5 14.8 3.1 25.6 8 325 21 307 165 -8.5 0 -8.3 -8.7 03/02/2007 02:20:00 15.3 3.6 23.7 6.5 14.7 3.8 24 6.1 14.8 3.3 24.8 6.8 335 17 344 165 -8.5 0.1 -8.3 -8.7 03/02/2007 02:30:00 17.3 3.8 31.3 8.4 15 3.6 28.3 6.5 16.7 3.6 29.1 8 353 23 1 165 -8.6 0 -8.5 -8.9 03/02/2007 02:40:00 17.3 3.5 30.2 7.2 14.9 3.6 26.3 6.8 16.9 3.6 28.3 8.4 357 18 355 165 -8.5 0 -8.3 -8.9 03/02/2007 02:50:00 14.8 3.2 25.2 8.4 13.8 3.2 25.2 6.8 14.2 2.8 24 8.4 341 18 344 165 -8.5 0 -8.3 -8.7 03/02/2007 03:00:00 16.8 3.5 28.3 9.9 15.2 3.6 25.6 8 16.5 3.5 27.1 10.7 348 22 357 165 -8.5 0 -8.3 -8.5 03/02/2007 03:10:00 17.2 3.2 24.8 9.1 16 3.5 24.4 7.2 16.5 3.3 24.8 7.2 339 24 320 165 -8.5 0 -8.5 -8.7 03/02/2007 03:20:00 16.8 3.3 25.2 9.9 14.8 3.3 24.8 8 16.4 3.3 26.3 9.9 351 16 359 165 -8.6 0 -8.5 -8.9 03/02/2007 03:30:00 17.3 3.2 25.2 9.9 16.4 3.8 24.4 6.5 16.9 3.1 23.7 9.5 337 20 314 165 -8.4 0 -8.1 -8.7 03/02/2007 03:40:00 19.5 5.1 31.8 8.4 17.1 4.9 30.6 7.2 19.3 5.1 31.8 8.8 349 20 11 165 -8.4 0 -8.1 -8.7 03/02/2007 03:50:00 17.9 3.6 30.9 10.7 16.5 3.5 31.8 8.8 17.6 3.8 32.1 11.1 339 20 341 165 -8.2 0 -8.1 -8.5 03/02/2007 04:00:00 17.8 3.6 30.6 10.7 17.1 4 30.6 8.4 17.1 4 29.8 9.9 331 17 340 165 -8.3 0 -8.1 -8.5 03/02/2007 04:10:00 16.4 2.9 23.7 10.3 14.5 2.9 22.9 8 16.1 2.9 25.6 9.9 346 20 9 165 -8.5 0 -8.3 -8.7 03/02/2007 04:20:00 18.1 2.8 26 11.5 17.8 2.8 26 11.5 17.3 2.9 26.3 9.5 328 14 317 165 -8.3 0 -8.1 -8.5 03/02/2007 04:30:00 16.1 3.5 27.9 9.1 15.6 3.6 27.9 8 15.2 3.5 26.8 8 327 17 325 165 -8.4 0 -8.1 -8.5 03/02/2007 04:40:00 15.8 3.2 22.6 7.6 15.3 3.5 22.9 7.6 15.2 2.9 22.6 8 328 17 321 165 -8.3 0 -8.1 -8.5 03/02/2007 04:50:00 16.4 3.6 29.4 7.6 16.1 3.8 28.3 6.5 15.9 3.3 26.8 8 324 15 316 165 -8.3 0 -8.1 -8.5 03/02/2007 05:00:00 16.1 3.5 25.6 6.8 15.3 4.1 25.2 6.1 15.1 3.6 26.8 5.3 329 20 326 165 -8.5 0 -8.3 -8.5 03/02/2007 05:10:00 15.9 3.1 24.4 9.9 15.6 3.2 24 8.8 15.1 3.1 26.8 7.2 330 16 302 165 -8.5 0 -8.3 -8.7 03/02/2007 05:20:00 18.4 3.5 27.1 10.3 17.5 3.8 26.8 8.4 18 3.5 27.1 11.1 337 19 344 165 -8.3 0.1 -8.1 -8.7 03/02/2007 05:30:00 16.8 3.5 28.3 10.7 15.6 4 27.5 8.4 16.2 3.5 26.8 9.5 337 17 317 165 -8.5 0.1 -8.3 -8.5 03/02/2007 05:40:00 16.7 2.8 24.8 11.1 15.3 3.3 24.4 7.2 15.9 2.8 24.8 9.1 338 20 331 165 -8.6 0 -8.3 -8.7 03/02/2007 05:50:00 17.8 2.9 26.8 11.1 15 3.3 27.1 8.4 17.9 3.2 27.5 10.3 356 14 15 165 -8.4 0.1 -8.1 -8.7 03/02/2007 06:00:00 16.5 2.6 23.3 10.3 15 2.9 24 8 15.9 2.7 22.1 9.9 337 21 326 165 -8.5 0 -8.3 -8.7 03/02/2007 06:10:00 17.7 3.1 25.6 9.5 17.5 3.1 26.3 9.1 16.4 3.2 25.2 7.2 318 12 302 165 -8.3 0 -8.1 -8.7 03/02/2007 06:20:00 16.5 3.1 26 8.8 16.3 3.1 25.6 9.5 15.6 3.3 22.9 8.8 323 13 318 165 -8.3 0 -8.1 -8.5 03/02/2007 06:30:00 16.5 4.1 29.4 7.6 16.3 4 28.3 6.5 15.4 4.1 29.1 8 320 16 315 165 -8.2 0 -8.1 -8.5 03/02/2007 06:40:00 14.6 2.3 21.4 10.3 14.1 2.6 21.8 8.8 14.1 2.4 21.8 8.4 332 17 303 165 -8.4 0.1 -8.1 -8.5 03/02/2007 06:50:00 13.6 2.1 20.2 8.8 11.7 2.4 17.9 5.7 13.4 2 20.2 8.4 351 12 360 165 -8.5 0 -8.5 -8.7 03/02/2007 07:00:00 13.9 2.1 19.5 9.5 12.7 2.3 18.7 7.2 13.3 2.3 21 9.1 337 17 360 165 -8.5 0.1 -8.3 -8.9 03/02/2007 07:10:00 14.5 2.7 22.1 8.8 13.8 2.8 22.6 6.8 14 2.4 19.5 8 337 15 305 165 -8.5 0 -8.3 -8.9 03/02/2007 07:20:00 16.5 2.6 23.3 10.7 15.9 2.5 22.9 10.7 15.8 2.7 22.9 10.3 328 16 317 165 -8.4 0.1 -8.1 -8.7 03/02/2007 07:30:00 16 2.4 23.3 10.3 15.1 2.9 23.3 7.6 15.1 2.1 23.3 10.3 335 20 310 165 -8.4 0 -8.3 -8.5 03/02/2007 07:40:00 16.6 3.3 30.6 9.5 16.2 3.5 30.9 10.3 16.1 3.3 29.1 9.9 334 13 343 165 -8.5 0.1 -8.3 -8.7 03/02/2007 07:50:00 17.1 2.6 24 10.7 16.9 2.6 23.3 9.9 16.5 2.8 23.7 9.5 322 12 326 165 -8.4 0 -8.1 -8.7 03/02/2007 08:00:00 14.7 2.7 24.8 8 14.2 2.9 25.2 6.8 14 2.6 22.6 7.2 327 15 310 165 -8.3 0 -8.1 -8.5 03/02/2007 08:10:00 14.8 2.6 24.4 8 13.3 2.8 24.4 6.8 14.3 2.5 23.7 8.4 343 17 349 165 -8.4 0.1 -8.3 -8.5 03/02/2007 08:20:00 17.1 2.4 22.9 9.9 14.7 3.2 22.9 7.6 16.8 2.3 22.9 11.8 356 16 349 165 -8.2 0.2 -7.9 -8.7 03/02/2007 08:30:00 16.9 2.8 22.9 11.1 13.9 2.6 21 7.6 17.1 2.9 23.3 10.7 354 14 5 165 -8 0 -7.6 -8.1 03/02/2007 08:40:00 17.7 2.6 26.3 11.5 14 3.2 24.8 8 17.9 2.6 27.1 11.1 357 11 15 165 -7.8 0 -7.6 -8.1 03/02/2007 08:50:00 16.9 2.6 24.4 10.7 14 3.1 23.7 7.6 16.9 2.7 23.7 11.5 353 14 3 165 -7.5 0.1 -7.4 -7.9 03/02/2007 09:00:00 17.9 3.5 27.5 9.9 15.5 3.2 25.6 8 18 3.6 27.5 10.3 350 17 8 165 -7.5 0 -7.4 -7.6 03/02/2007 09:10:00 16.1 2.3 23.3 11.8 14.5 2.5 21.8 8 16.2 2.4 23.3 9.9 344 15 348 165 -7.5 0.1 -7.2 -7.9 03/02/2007 09:20:00 17 2.7 24.4 10.7 15.6 3.2 24.8 8.8 16.9 2.6 23.7 11.8 337 18 12 165 -7.4 0 -7.2 -7.6 03/02/2007 09:30:00 16.3 2.6 23.3 10.7 15.5 2.9 22.9 8 15.9 2.2 24.4 9.5 333 19 318 165 -7.3 0.1 -7 -7.6 03/02/2007 09:40:00 14.4 1.9 19.5 9.1 13.1 2.5 19.1 6.5 14.3 1.9 19.9 10.3 347 15 319 165 -7 0.1 -6.8 -7.2 03/02/2007 09:50:00 15 2.8 21.8 8 12.9 3.2 21.4 6.5 14.8 2.8 21.8 9.1 353 15 7 165 -6.9 0 -6.8 -7.2 03/02/2007 10:00:00 16.9 2.7 24.8 9.9 14.3 2.8 22.6 8 16.8 2.8 24 9.9 353 15 6 165 -6.9 0 -6.8 -7 03/02/2007 10:10:00 17.9 2.4 24.8 12.6 14.7 2.9 22.1 8.4 17.8 2.3 24.4 12.6 353 14 2 165 -6.9 0 -6.6 -7 03/02/2007 10:20:00 17.5 2.3 24 12.6 13.5 2.8 22.1 8.8 17.8 2.3 24 11.5 358 13 14 165 -6.8 0 -6.6 -6.8 03/02/2007 10:30:00 18.6 2.5 24.4 11.8 14.7 3.1 23.7 8.4 18.8 2.6 25.6 11.5 359 11 10 165 -6.8 0 -6.6 -6.8 03/02/2007 10:40:00 19.2 2.6 24.8 11.5 15.1 3.2 24.4 9.9 19.4 2.8 26.3 12.6 359 13 314 165 -6.7 0 -6.6 -7 03/02/2007 10:50:00 17.4 2.7 23.7 9.5 14.4 2.5 22.1 7.6 17.5 3.1 26.3 10.7 357 16 10 165 -6.5 0 -6.4 -6.8 03/02/2007 11:00:00 17.1 2.2 24.4 11.5 13.4 2.8 21.4 8 17.1 2.3 24.4 9.1 5 11 6 165 -6.4 0 -6.1 -6.6 03/02/2007 11:10:00 15.2 2.2 22.1 9.1 11.9 2.5 20.6 6.5 15.1 2.3 22.1 9.1 355 12 360 165 -6.1 0.1 -5.9 -6.6 03/02/2007 11:20:00 14.2 1.9 20.6 10.7 11.3 2.3 18.3 6.8 13.9 2 20.2 9.5 356 11 0 165 -5.9 0.1 -5.7 -6.1 03/02/2007 11:30:00 13.5 1.7 18.3 9.5 13.1 1.8 17.9 7.6 12.9 1.5 17.2 9.5 334 11 326 165 -5.9 0.1 -5.5 -6.1 03/02/2007 11:40:00 14.2 1.9 17.9 9.5 12.2 2.4 19.1 6.1 13.9 2 18.3 8.4 353 15 350 165 -5.7 0.1 -5.5 -5.9 03/02/2007 11:50:00 15.7 2.7 22.6 10.3 12.5 2.9 19.5 7.2 15.8 2.7 22.1 9.5 360 13 6 165 -5.8 0 -5.5 -6.1 03/02/2007 12:00:00 16.5 2.3 23.3 9.9 13.3 2.8 22.1 7.2 16.7 2.3 23.3 10.7 4 14 16 165 -5.8 0 -5.5 -5.9 03/02/2007 12:10:00 16.2 2.9 23.3 9.1 12.5 3.2 22.6 5.7 16.3 3.1 24 9.5 0 12 15 165 -5.6 0.1 -5.5 -5.9 03/02/2007 12:20:00 14.6 2.2 20.2 9.9 11.9 2.8 21 6.5 14.4 2.4 21 8.8 359 14 16 165 -5.6 0 -5.5 -5.7 03/02/2007 12:30:00 17.6 2.2 25.2 12.6 13.4 3.1 24 7.6 17.5 2.3 23.3 12.2 3 15 24 165 -5.6 0 -5.5 -5.7 03/02/2007 12:40:00 15.3 2.1 20.2 9.9 12.5 2.6 19.5 5.7 15.1 2 22.1 8.8 4 14 7 165 -5.4 0.1 -5.3 -5.9 03/02/2007 12:50:00 14.6 2.6 21.4 9.5 11.9 2.6 19.1 6.8 14.2 2.6 22.1 8.4 354 16 337 165 -5.2 0.1 -4.8 -5.5 03/02/2007 13:00:00 15.2 3.1 24 7.6 11.9 2.9 22.9 6.5 15.1 3.1 22.1 5.7 3 15 10 165 -5.3 0 -5 -5.5 03/02/2007 13:10:00 12.9 2 20.2 9.1 11.7 2.4 18.7 6.5 12.5 2.3 21.4 8.8 346 13 1 165 -5 0 -4.6 -5.5 03/02/2007 13:20:00 13.2 1.9 19.9 8.8 12.9 2 20.6 8.4 12.6 2 19.1 6.8 331 11 316 165 -5 0.1 -4.6 -5.3 03/02/2007 13:30:00 13.3 2 19.1 8.4 13.1 2 18.7 8 12.5 2.1 17.9 6.8 328 11 324 165 -5.2 0.1 -4.8 -5.5 03/02/2007 13:40:00 13.2 2 17.9 6.8 11.5 2.1 15.6 4.9 12.6 2.2 18.3 5.3 342 22 355 165 -4.9 0 -4.6 -5.3 03/02/2007 13:50:00 11.9 2.2 17.9 6.5 11 2 16.4 6.1 11.5 2.1 17.2 6.5 335 18 357 165 -4.9 0.2 -4.4 -5.5 03/02/2007 14:00:00 11.7 2 16.1 6.5 10.9 2.5 16.1 4.9 11.1 2.1 15.3 6.1 337 18 339 165 -4.8 0.1 -4.6 -5.5 03/02/2007 14:10:00 12.8 2.2 18.7 7.6 12.4 2.4 18.3 5.7 12 2.4 18.7 6.1 332 15 345 165 -4.9 0 -4.6 -5.7 03/02/2007 14:20:00 14.1 2.7 21 5.3 13.4 3.1 20.2 5.3 13.5 2.7 21.4 5.7 330 20 334 165 -5 0.1 -4.6 -5.5 03/02/2007 14:30:00 16.7 2.8 25.2 10.3 16.3 2.8 25.2 9.5 15.8 3.1 24.8 9.1 326 10 330 165 -5.2 0.2 -5 -5.5 03/02/2007 14:40:00 15 2.3 22.1 9.5 14.8 2.3 22.9 9.5 14.4 2.4 21.8 8.8 325 13 316 165 -5.3 0.1 -5 -5.5 03/02/2007 14:50:00 13.4 2 19.5 8 13.2 1.9 18.7 8.4 12.7 2 18.3 8 326 11 310 165 -5 0 -4.6 -5.3 03/02/2007 15:00:00 13.8 2.9 24.8 8 12.7 3.3 24.4 6.8 13.5 2.8 22.1 7.6 338 19 334 165 -5 0.1 -4.6 -5.3 03/02/2007 15:10:00 12.9 2.5 20.2 5.7 12.5 2.7 19.9 4.6 12 2.5 22.1 5.7 328 20 319 165 -5 0 -4.6 -5.3 03/02/2007 15:20:00 12 1.8 16.4 8 11 2.1 15.6 4.9 11.6 2 17.9 6.8 344 17 351 165 -4.7 0.1 -4.4 -5 03/02/2007 15:30:00 13.8 2.7 21 6.5 12.9 2.9 21 6.1 13.2 2.7 21.4 7.6 332 17 310 165 -4.9 0 -4.6 -5.3 03/02/2007 15:40:00 13.1 2.6 21 6.8 12.8 2.7 21.4 6.5 12.1 2.6 21 6.8 328 13 343 165 -5.1 0 -4.8 -5.3 03/02/2007 15:50:00 12.1 2.2 18.3 6.8 11.1 2.7 18.3 5.3 11.8 2.1 17.6 6.1 345 22 304 165 -4.8 0 -4.6 -5 03/02/2007 16:00:00 15.6 2.6 22.9 8.8 15.4 2.5 22.1 8.4 15 2.6 21.8 8.4 325 12 338 165 -5.2 0 -5 -5.5 03/02/2007 16:10:00 15.6 2.8 21.8 8.4 15.4 2.7 21.8 8.4 15.2 2.8 22.6 9.1 322 11 312 165 -5.3 0 -5 -5.5 03/02/2007 16:20:00 15.2 2.3 22.1 9.5 15 2.3 22.6 9.5 14.2 2.5 21.4 8.8 319 10 325 165 -5.3 0 -5 -5.5 03/02/2007 16:30:00 14.6 3.1 22.1 8.8 14.3 3.1 22.1 8.8 14.1 3.3 23.3 8 324 12 336 165 -5.4 0 -5 -5.5 03/02/2007 16:40:00 12.4 2.2 19.1 6.5 11.6 2.3 18.3 6.5 12 2.1 18.3 7.2 337 14 319 165 -5.4 0 -5 -5.7 03/02/2007 16:50:00 14.2 2.8 22.9 7.6 14 2.8 22.1 6.8 13.4 2.7 21.8 7.2 322 16 332 165 -5.6 0.1 -5.5 -5.9 03/02/2007 17:00:00 13.9 2.7 21 7.6 13.5 2.9 21 6.8 13.5 2.7 21 7.2 332 15 330 165 -5.6 0 -5.5 -5.9 03/02/2007 17:10:00 16.5 4 26.3 6.5 16.2 4 26.3 6.8 15.8 4 26 8 320 15 315 165 -5.9 0 -5.7 -6.1 03/02/2007 17:20:00 17.6 3.8 26.3 8.4 17.3 3.8 26.8 8.8 17.1 4.1 26.3 6.5 324 13 336 165 -6.1 0 -5.7 -6.1 03/02/2007 17:30:00 18.8 3.8 26 9.5 18.6 3.8 26 6.8 18.6 3.6 28.7 9.5 326 15 331 165 -6.1 0 -5.9 -6.4 03/02/2007 17:40:00 16.4 2.8 25.6 9.1 16.1 2.8 25.2 7.2 15.7 2.8 23.7 8.8 322 14 330 165 -6.2 0.1 -5.9 -6.4 03/02/2007 17:50:00 16.9 3.3 25.6 9.1 16.6 3.3 24.8 8.8 16.3 3.6 28.3 8.4 326 12 332 165 -6.2 0.1 -6.1 -6.6 03/02/2007 18:00:00 16.9 3.3 24.8 9.1 16.6 3.3 24.4 8.4 15.8 3.2 24 7.6 326 13 319 165 -6.4 0 -6.1 -6.6 03/02/2007 18:10:00 17.3 2.9 25.6 10.7 17.1 2.9 26 10.3 16.2 3.2 24.4 3 322 12 338 165 -6.4 0 -6.1 -6.6 03/02/2007 18:20:00 14.7 3.6 24 8.8 14.4 3.6 24 7.6 13.4 3.8 22.9 4.6 329 15 344 165 -6.6 0 -6.4 -6.8 03/02/2007 18:30:00 15.2 3.2 23.7 6.8 14.5 3.3 23.3 6.5 14.3 3.3 22.6 4.6 331 16 340 165 -6.8 0 -6.6 -7 03/02/2007 18:40:00 17.8 2.5 25.2 12.6 17.4 2.6 24.8 11.5 17.1 2.5 24.8 10.7 332 12 315 165 -6.8 0 -6.6 -7 03/02/2007 18:50:00 17.6 2.6 26 11.8 17.3 2.6 25.2 10.3 16.5 2.7 24 10.7 323 13 321 165 -6.8 0 -6.6 -7 03/02/2007 19:00:00 18.6 2.3 23.7 12.6 18.3 2.2 23.3 12.2 18 2.3 24 11.1 329 11 324 165 -6.7 0 -6.6 -7 03/02/2007 19:10:00 17.9 2.8 24.8 9.5 17.6 2.9 24.4 7.6 17.2 2.9 25.2 8 325 13 332 165 -6.7 0 -6.6 -7 03/02/2007 19:20:00 18.2 2.6 24.4 10.7 17.8 2.7 24 11.1 17.5 2.6 25.6 12.2 330 13 328 165 -6.7 0 -6.6 -6.8 03/02/2007 19:30:00 18.9 3.3 27.1 10.7 18.6 3.3 25.6 9.5 18.3 3.3 25.6 9.9 329 13 332 165 -6.7 0 -6.6 -6.8 03/02/2007 19:40:00 19.6 2.7 26.3 13.3 19.3 2.7 27.1 13 19.1 2.6 25.2 13 329 12 342 165 -6.6 0 -6.6 -6.8 03/02/2007 19:50:00 21.4 2.5 30.6 15.3 21.1 2.6 30.2 13.3 20.7 2.8 28.7 13 331 10 341 165 -6.6 0 -6.4 -6.8 03/02/2007 20:00:00 18.8 3.2 24.8 11.1 18.5 3.3 24.4 9.9 18.7 3.3 26 9.5 330 13 326 165 -6.5 0 -6.4 -6.8 03/02/2007 20:10:00 18 2.8 30.6 13.3 17.7 2.9 29.8 11.8 17.9 2.9 29.1 8.8 331 13 318 165 -6.5 0 -6.4 -6.6 03/02/2007 20:20:00 19.5 2.4 25.2 13.7 19.3 2.4 24.4 13.7 19.5 2.6 26 11.8 329 10 322 165 -6.5 0 -6.4 -6.8 03/02/2007 20:30:00 19.9 2.7 26.3 13.3 19.6 2.8 26.3 12.2 20 2.8 28.3 13 332 11 324 165 -6.4 0 -6.1 -6.6 03/02/2007 20:40:00 19.2 2.5 26 11.8 18.8 2.6 26 11.5 18.9 2.5 27.1 11.1 331 14 326 165 -6.4 0 -6.1 -6.6 03/02/2007 20:50:00 18.9 2.5 24.8 11.1 18.8 2.5 25.2 11.1 18.9 2.3 25.6 13.3 325 12 334 165 -6.4 0 -6.1 -6.6 03/02/2007 21:00:00 18.3 2.7 24.8 11.8 18.1 2.7 24.8 11.5 18 2.8 25.6 10.7 327 12 325 165 -6.4 0 -6.1 -6.6 03/02/2007 21:10:00 20.3 2.6 27.5 12.6 20 2.6 26.8 12.6 19.8 2.7 25.6 11.1 331 9 328 165 -6.4 0 -6.1 -6.6 03/02/2007 21:20:00 21.5 1.9 26.8 16.8 21.3 1.8 26 16.8 21.1 2 26 15.3 330 9 332 165 -6.3 0 -6.1 -6.6 03/02/2007 21:30:00 21.5 1.9 27.1 15.6 21.4 1.9 27.5 15.6 21.1 2.2 26.8 14.1 332 9 337 165 -6.2 0 -5.9 -6.4 03/02/2007 21:40:00 21.5 2.1 28.3 15.3 21.3 2 29.4 15.6 21.3 1.9 28.3 16.1 331 8 333 165 -6.1 0 -5.9 -6.4 03/02/2007 21:50:00 19.4 2.5 26.8 13.3 19.2 2.5 26.8 13 19.1 2.5 26.3 12.2 328 10 348 165 -6.1 0 -5.9 -6.4 03/02/2007 22:00:00 19 2.6 26 12.2 18.6 2.7 25.6 10.3 18.7 2.7 26.8 12.2 331 12 326 165 -6 0 -5.7 -6.4 03/02/2007 22:10:00 18.8 3.1 27.1 9.9 18.5 3.2 27.1 9.5 18.4 3.3 27.5 9.1 328 14 319 165 -5.9 0 -5.7 -6.1 03/02/2007 22:20:00 18.2 2.7 25.2 11.5 17.9 2.7 24.8 9.9 17.5 2.8 25.6 11.1 324 10 312 165 -6 0 -5.7 -6.1 03/02/2007 22:30:00 19 2.9 26.8 11.5 18.8 2.9 26.3 12.2 18.7 3.1 25.2 11.1 323 12 315 165 -5.9 0.1 -5.5 -6.1 03/02/2007 22:40:00 17.4 2.8 24.4 8.8 17.1 2.7 24 8.4 16.5 3.1 24 8.8 326 11 325 165 -5.9 0 -5.5 -6.1 03/02/2007 22:50:00 17.6 2.9 27.5 11.1 17.3 2.9 27.9 9.9 16.7 3.1 27.1 10.3 326 14 333 165 -6 0 -5.7 -6.4 03/02/2007 23:00:00 17.6 2.2 23.3 10.7 17.3 2.2 24.4 11.1 17.1 2.3 24 12.2 324 13 335 165 -5.9 0 -5.7 -6.1 03/02/2007 23:10:00 17.8 2.7 24.4 11.8 17.5 2.7 24 11.5 17.3 2.9 26.3 9.9 323 13 305 165 -5.8 0 -5.5 -6.1 03/02/2007 23:20:00 16.7 3.6 25.6 9.1 16.3 3.8 25.6 8 15.9 3.8 25.2 7.6 324 17 336 165 -5.9 0 -5.5 -6.1 03/02/2007 23:30:00 16.5 2.7 24.4 8.8 16.3 2.8 23.7 8.8 16.1 2.7 23.7 10.3 326 14 326 165 -5.8 0.1 -5.5 -5.9 03/02/2007 23:40:00 19.6 2.6 26.3 12.2 19.3 2.8 26.3 9.9 19.2 2.8 25.2 12.2 330 13 329 165 -5.8 0 -5.5 -5.9 03/02/2007 23:50:00 19.7 2.9 29.1 12.2 19.5 2.9 28.3 11.8 19.3 2.9 27.9 11.1 324 14 331 165 -5.6 0 -5.5 -5.9 03/03/2007 00:00:00 18.5 2.9 24.8 11.8 18.2 3.1 24.4 8 17.9 2.9 25.6 11.5 328 12 328 165 -5.8 0 -5.5 -5.9 03/03/2007 00:10:00 18.3 2.4 25.2 13 17.9 2.4 24.8 12.6 17.3 2.5 25.2 11.5 326 11 329 165 -5.9 0 -5.7 -6.1 03/03/2007 00:20:00 22 2.4 29.1 14.5 21.5 2.7 27.9 11.8 21.5 2.6 27.1 14.5 332 12 328 165 -5.8 0 -5.5 -6.1 03/03/2007 00:30:00 20.7 2.3 25.2 14.1 20.2 2.5 24.8 12.6 20 2.5 24.8 13.3 333 12 332 165 -5.8 0 -5.5 -5.9 03/03/2007 00:40:00 17 2.7 24 9.9 16.6 2.9 23.7 8.8 16.6 2.8 23.7 9.9 332 13 319 165 -5.8 0 -5.5 -5.9 03/03/2007 00:50:00 18.9 2.9 27.1 11.1 18.7 3.1 28.3 10.7 18.4 3.1 26.3 10.3 329 14 338 165 -5.9 0 -5.7 -6.1 03/03/2007 01:00:00 20.6 2.4 27.1 14.5 20.3 2.3 26 14.1 20.1 2.5 29.8 14.1 326 9 335 165 -5.8 0 -5.5 -5.9 03/03/2007 01:10:00 20.3 2.7 28.3 14.9 20.1 2.7 28.3 14.9 20 2.9 29.1 13.3 325 11 319 165 -5.6 0 -5.5 -5.9 03/03/2007 01:20:00 19.5 2.9 28.7 12.6 19.2 2.9 28.7 11.5 18.9 3.1 28.3 12.2 326 13 313 165 -5.5 0 -5.3 -5.7 03/03/2007 01:30:00 18.9 2.9 25.6 11.5 18.4 3.3 24.8 9.1 18.3 2.9 25.2 11.8 334 12 336 165 -5.6 0 -5.5 -5.7 03/03/2007 01:40:00 18.9 2.9 26.3 9.9 18.6 2.8 26.3 10.3 17.8 3.1 24.8 9.5 328 12 325 165 -5.6 0 -5.3 -5.9 03/03/2007 01:50:00 16.7 2.2 21.8 11.5 16.4 2.3 21.8 10.3 15.8 2.5 21.4 9.1 327 12 339 165 -5.5 0 -5.3 -5.7 03/03/2007 02:00:00 12.8 3.3 25.6 7.2 12.5 3.5 27.1 6.1 12.2 3.3 23.7 5.3 326 17 318 165 -5.5 0 -5.3 -5.9 03/03/2007 02:10:00 14.7 2.9 23.7 7.2 14.4 2.9 22.9 7.6 14 3.1 21.8 7.2 326 14 325 165 -5.5 0 -5.3 -5.7 03/03/2007 02:20:00 14.6 2.5 21.8 9.5 14.5 2.6 21.8 9.1 14.1 2.6 21.4 8.4 327 15 308 165 -5.6 0 -5.5 -5.7 03/03/2007 02:30:00 15.3 2.7 21.8 8 15.2 2.7 21.8 8 15.1 2.8 20.6 8 329 13 322 165 -5.5 0 -5.5 -5.7 03/03/2007 02:40:00 14.3 2.4 24.8 9.5 14.1 2.4 24.8 9.1 13.7 2.4 22.9 9.9 322 11 330 165 -5.6 0 -5.5 -5.7 03/03/2007 02:50:00 13.9 3.1 22.9 7.6 13.7 3.2 22.6 5.7 13.5 3.2 21.4 7.6 324 15 310 165 -5.5 0 -5.5 -5.7 03/03/2007 03:00:00 16.6 2.5 26 11.1 16.4 2.4 26 10.7 16.3 2.6 25.2 10.7 324 12 323 165 -5.5 0 -5.5 -5.7 03/03/2007 03:10:00 16.6 2.6 22.9 10.7 16.2 2.6 22.6 8.4 16.1 2.7 22.9 10.3 327 13 312 165 -5.5 0 -5.3 -5.7 03/03/2007 03:20:00 17.2 2.9 24 8.8 16.8 3.1 24.4 9.5 16.7 3.1 23.3 8.4 327 14 329 165 -5.5 0 -5.3 -5.7 03/03/2007 03:30:00 17.3 2.8 24.4 8 17.1 2.8 23.3 8 16.8 3.1 24 7.6 324 15 318 165 -5.6 0 -5.5 -5.7 03/03/2007 03:40:00 20.1 2.6 26.8 14.1 19.7 2.8 26.3 12.2 19.6 2.7 27.5 13.3 331 11 341 165 -5.5 0 -5.5 -5.7 03/03/2007 03:50:00 19.3 2.8 27.9 11.5 19 2.8 27.5 11.8 18.5 3.1 27.5 9.5 329 11 329 165 -5.6 0 -5.5 -5.7 03/03/2007 04:00:00 19.2 2.2 26 12.6 18.7 2.4 25.6 8.8 18.7 2.5 26 10.7 331 9 328 165 -5.5 0 -5.5 -5.7 03/03/2007 04:10:00 16.2 2.5 25.2 10.3 16 2.5 24.8 10.3 15.6 2.6 23.7 10.3 326 13 302 165 -5.5 0 -5.3 -5.7 03/03/2007 04:20:00 14.1 3.1 21.8 8 13.8 3.1 21.4 6.8 13.5 3.2 21.8 7.2 328 15 338 165 -5.5 0 -5.3 -5.7 03/03/2007 04:30:00 15.1 2.9 22.6 8.4 14.6 3.1 21.8 5.3 14.5 2.9 22.6 7.2 332 13 328 165 -5.5 0 -5.3 -5.7 03/03/2007 04:40:00 14.6 2.8 22.9 8 14.5 2.9 23.7 6.8 14.3 2.9 23.3 7.6 326 15 343 165 -5.4 0 -5.3 -5.7 03/03/2007 04:50:00 12.5 3.2 22.1 6.8 12.4 3.2 21.8 6.8 12.3 3.2 21.4 6.8 327 12 332 165 -5.4 0 -5.3 -5.7 03/03/2007 05:00:00 9.2 2 15.3 3.4 9.1 2 14.5 4.6 8.8 2 14.5 4.2 324 16 325 165 -5.5 0 -5.3 -5.7 03/03/2007 05:10:00 12 3.3 20.6 3.8 11.6 3.3 19.9 3 11.3 3.6 19.9 4.2 329 17 328 165 -5.4 0 -5 -5.7 03/03/2007 05:20:00 14.7 2.5 21.8 10.3 14.4 2.4 21 9.9 14.3 2.3 21.8 9.5 329 9 322 165 -5.5 0 -5.3 -5.7 03/03/2007 05:30:00 15.5 2.3 20.2 10.3 15.2 2.6 19.9 6.5 15.4 2.4 20.6 10.3 333 10 331 165 -5.5 0 -5.3 -5.7 03/03/2007 05:40:00 14.9 2.3 21.4 9.1 14.6 2.4 22.6 9.1 14.5 2.2 21.4 8.8 333 9 347 165 -5.5 0 -5.5 -5.7 03/03/2007 05:50:00 13.8 2.5 20.6 7.6 13.5 2.6 19.9 6.8 13.6 2.6 21.8 8 327 13 337 165 -5.5 0.1 -5.3 -5.7 03/03/2007 06:00:00 12.8 3.1 19.1 5.3 12.7 3.1 18.7 5.7 12.5 3.1 20.2 6.1 326 15 328 165 -5.5 0.1 -5.3 -5.7 03/03/2007 06:10:00 11.5 2.5 18.3 6.8 11.2 2.5 18.3 6.8 11 2.7 18.3 6.1 327 13 330 165 -5.6 0 -5.5 -5.7 03/03/2007 06:20:00 11.3 2.1 15.3 5.7 11 2.1 14.9 5.3 11.2 2.2 16.1 6.1 333 13 351 165 -5.6 0 -5.5 -5.7 03/03/2007 06:30:00 11.3 2.4 17.2 6.5 11.1 2.4 17.6 6.5 10.8 2.4 16.4 5.7 327 11 319 165 -5.8 0 -5.5 -5.9 03/03/2007 06:40:00 10.6 2.3 16.1 4.9 10.4 2.3 16.1 4.9 10.1 2.3 15.6 4.6 324 13 309 165 -5.7 0 -5.5 -5.7 03/03/2007 06:50:00 9.5 2.6 16.1 3 9.2 2.7 16.1 2.6 9.2 2.6 16.4 2.3 328 18 330 165 -5.5 0 -5.5 -5.7 03/03/2007 07:00:00 8.5 2.3 15.3 3.8 8.4 2.3 14.9 3.8 7.8 2.2 14.5 3.4 314 17 319 165 -5.4 0 -5.3 -5.7 03/03/2007 07:10:00 11.1 1.7 14.9 7.2 10.9 1.7 14.5 6.5 10.5 2.1 14.9 5.7 317 15 315 165 -5.4 0 -5.3 -5.7 03/03/2007 07:20:00 12.4 1.8 16.4 5.7 12.2 1.9 16.8 6.1 12.1 2 17.2 5.7 327 12 328 165 -5.5 0 -5.3 -5.7 03/03/2007 07:30:00 11.7 1.7 16.4 6.1 11.6 1.8 16.8 6.1 11.5 1.7 17.6 7.2 330 11 348 165 -5.7 0.1 -5.5 -5.7 03/03/2007 07:40:00 10.8 2.3 16.4 4.9 10.6 2.3 16.4 3.8 10.2 2.4 16.4 4.6 327 15 327 165 -5.8 0 -5.5 -6.1 03/03/2007 07:50:00 9.8 2.7 16.4 4.2 9.4 2.8 15.6 3.4 9.6 2.9 17.2 3 338 13 350 165 -5.7 0.1 -5.5 -5.7 03/03/2007 08:00:00 14.8 2.2 20.6 9.5 14.4 2.4 19.9 6.8 14.6 2.3 20.6 9.5 335 10 338 165 -5.8 0 -5.5 -5.9 03/03/2007 08:10:00 14.3 2 18.7 8 14.1 2.1 18.7 6.5 14.1 2.1 19.1 7.6 338 9 325 165 -5.6 0 -5.5 -5.7 03/03/2007 08:20:00 12.2 2 17.6 8 11.9 2.1 17.9 5.3 11.9 1.9 17.6 8 337 9 309 165 -5.4 0.1 -5.3 -5.9 03/03/2007 08:30:00 13.2 1.5 17.6 8.8 12.7 1.8 17.2 6.8 13 1.6 18.7 9.1 339 11 339 165 -5.3 0 -5 -5.7 03/03/2007 08:40:00 12.7 1.5 18.7 9.9 12.2 2 19.1 5.7 12.1 1.7 18.3 8.4 338 11 316 165 -5.2 0 -4.8 -5.3 03/03/2007 08:50:00 10.9 1.6 19.1 7.2 10.6 1.5 19.1 6.8 10.1 1.5 17.2 6.8 339 9 343 165 -4.8 0 -4.6 -5.3 03/03/2007 09:00:00 11.5 1.3 14.9 7.2 10.8 1.8 14.9 5.3 10.6 1.5 14.9 6.1 344 9 352 165 -4.5 0 -4.2 -5 03/03/2007 09:10:00 10.1 1.4 13.3 4.6 9.6 1.8 13.3 4.2 9 1.5 13 5.3 340 12 341 165 -4.3 0 -4.2 -4.6 03/03/2007 09:20:00 9.6 1.7 14.1 5.7 9.4 1.7 14.5 5.3 8.6 1.7 13.7 4.9 337 9 344 165 -4.3 0.1 -3.9 -4.6 03/03/2007 09:30:00 9.2 1.7 13.7 5.3 8.9 1.8 13 4.2 8.6 1.7 12.2 4.2 337 10 334 165 -4.1 0 -3.7 -4.4 03/03/2007 09:40:00 9.3 1.1 12.2 6.8 9.1 1.2 12.2 6.1 8.5 1.3 11.5 5.3 333 10 338 165 -4 0.1 -3.7 -4.4 03/03/2007 09:50:00 9.6 1.5 14.1 6.1 9.1 1.7 13.7 5.3 9.4 1.5 13.3 6.1 343 10 335 165 -3.8 0 -3.5 -3.9 03/03/2007 10:00:00 11 1.7 15.6 6.5 10.6 1.8 16.1 6.1 10.5 1.7 15.6 5.7 340 10 354 165 -3.9 0 -3.5 -4.2 03/03/2007 10:10:00 10.4 1.5 14.1 6.5 10.2 1.6 14.1 5.3 9.9 1.5 14.5 6.8 340 9 336 165 -3.8 0.2 -3.5 -4.2 03/03/2007 10:20:00 7.4 1.8 11.5 3.4 6.8 1.9 11.5 3 6.6 1.8 10.7 2.6 353 18 337 165 -3.4 0.1 -2.8 -3.9 03/03/2007 10:30:00 8.2 2.3 14.1 4.2 7.8 2.7 14.1 3 7.8 2.6 13.7 3.4 344 11 343 165 -3.5 0.1 -3.3 -4.2 03/03/2007 10:40:00 9.9 1.7 14.1 5.3 9.9 1.6 13.7 5.3 9.6 1.8 13.7 4.9 336 8 335 165 -3.7 0.2 -3.5 -4.6 03/03/2007 10:50:00 8.4 1.6 12.2 4.6 8.2 1.7 11.8 4.2 8 1.6 12.2 4.2 336 10 336 165 -3.3 0.3 -2.8 -3.9 03/03/2007 11:00:00 11.2 1.9 18.3 7.2 10.8 2.2 17.6 6.1 11 1.9 17.6 6.8 341 9 335 165 -3.4 0 -3 -3.5 03/03/2007 11:10:00 11.9 1.4 15.3 7.6 11.5 1.5 14.9 6.1 11.6 1.3 14.9 8 336 11 351 165 -3.5 0.1 -3.3 -3.9 03/03/2007 11:20:00 10.9 1.7 14.9 6.8 10.8 1.7 14.9 6.8 10.6 1.9 14.9 6.5 334 8 344 165 -3.3 0 -3 -3.9 03/03/2007 11:30:00 11.2 1.5 14.9 7.2 11.1 1.6 14.9 7.6 11 1.5 15.3 7.6 337 7 347 165 -3.4 0.2 -3 -3.9 03/03/2007 11:40:00 11.9 1.1 14.5 8.8 11.8 1.1 14.1 8.8 11.7 1.2 14.1 8 336 6 334 165 -3.4 0.1 -3 -3.9 03/03/2007 11:50:00 9.9 1.3 13 6.1 9.9 1.4 13 6.5 9.9 1.5 13.7 5.7 338 7 328 165 -3.3 0.2 -3 -4.2 03/03/2007 12:00:00 10.4 0.9 13 8 10.6 1 13 7.2 10.6 0.9 12.6 8.4 343 4 340 165 -3.3 0.2 -3 -3.9 03/03/2007 12:10:00 8.7 0.8 11.1 6.5 8.8 1 11.5 6.1 8.9 0.9 11.5 6.8 341 6 338 165 -3.1 0.2 -2.6 -3.5 03/03/2007 12:20:00 9.5 1 11.5 6.5 9.6 1.1 11.5 6.5 9.4 1.1 11.5 6.1 341 5 334 165 -3 0 -2.8 -3.3 03/03/2007 12:30:00 8.5 1.2 11.5 5.7 8.4 1.4 11.5 3 8.3 1.1 11.1 5.7 342 8 338 165 -2.9 0 -2.6 -3.3 03/03/2007 12:40:00 7.9 0.9 9.9 6.1 7.9 1 10.3 5.7 7.9 1 10.3 5.3 338 8 333 165 -2.8 0.2 -2.6 -3.3 03/03/2007 12:50:00 8.6 0.9 11.1 4.6 8.6 1.1 11.5 3.8 8.8 0.9 11.8 6.5 338 10 339 165 -2.8 0.1 -2.6 -3 03/03/2007 13:00:00 7 1 9.1 4.9 6.6 0.9 8.8 3.8 6.9 1.1 9.1 4.2 336 16 353 165 -2.6 0.2 -2.4 -3.3 03/03/2007 13:10:00 6.9 0.9 10.7 4.6 6.7 1 10.7 4.6 6.5 1 9.9 4.2 329 13 333 165 -2.5 0.1 -2.1 -3 03/03/2007 13:20:00 8.2 1.4 12.6 5.7 8.2 1.5 13 5.3 8.2 1.6 13 4.9 334 10 349 165 -2.5 0 -2.1 -2.8 03/03/2007 13:30:00 8 1 11.1 5.7 7.7 1.3 11.1 3.8 8 1 11.1 5.7 342 8 341 165 -2.4 0 -2.1 -2.6 03/03/2007 13:40:00 7.8 0.9 9.9 5.7 7.5 1.2 9.9 3.8 7.8 1 10.3 4.9 340 12 340 165 -2.4 0 -1.9 -2.8 03/03/2007 13:50:00 7.3 1.1 10.3 4.9 7.1 1.2 10.7 3.8 7.2 1 9.5 4.9 345 8 342 165 -2.1 0.2 -1.7 -2.6 03/03/2007 14:00:00 7.4 1 9.5 4.6 7.4 1 9.5 4.6 7.3 1 9.5 4.6 339 8 347 165 -2.2 0.1 -1.7 -2.8 03/03/2007 14:10:00 6.4 1.2 9.9 4.2 6 1.4 9.5 2.6 6.6 1.1 9.9 4.6 343 11 332 165 -2 0.1 -1.7 -2.6 03/03/2007 14:20:00 7.6 0.8 9.5 5.7 7.5 0.8 9.5 4.9 7.6 0.8 9.5 5.3 338 9 328 165 -2.4 0.1 -1.9 -3 03/03/2007 14:30:00 6.4 0.9 9.9 4.6 6.3 0.9 9.5 3.4 6.5 0.9 10.3 4.9 341 7 354 165 -2.1 0 -1.9 -2.6 03/03/2007 14:40:00 6.6 0.7 8.8 4.6 6.5 0.9 8.8 3 6.6 0.8 8.8 4.6 337 9 334 165 -2.1 0.1 -1.7 -2.6 03/03/2007 14:50:00 6.6 0.7 9.1 5.3 6.6 0.7 8.8 5.3 6.8 0.7 8.8 4.9 328 11 328 165 -2.2 0.2 -1.9 -2.8 03/03/2007 15:00:00 7.1 0.8 9.5 5.3 7 0.8 9.9 5.3 7.2 0.9 9.1 5.3 333 8 348 165 -2.2 0 -1.9 -2.8 03/03/2007 15:10:00 6.7 1 9.5 4.9 6.7 1 9.9 4.2 6.7 1 9.1 4.9 336 9 344 165 -2.1 0.1 -1.7 -2.6 03/03/2007 15:20:00 6.6 0.7 9.1 4.9 6.4 1 9.1 3.4 6.7 0.8 9.1 4.9 342 8 344 165 -2.3 0.2 -1.9 -2.8 03/03/2007 15:30:00 6.7 0.7 9.1 5.3 6.7 0.7 9.1 5.3 6.8 0.7 8.4 5.3 336 8 338 165 -2.3 0.1 -1.9 -2.8 03/03/2007 15:40:00 7.4 1 9.5 5.3 7.3 1 9.5 4.6 7.4 0.9 9.9 5.7 341 7 336 165 -2.3 0 -1.9 -2.8 03/03/2007 15:50:00 6.9 0.7 9.5 5.3 6.8 0.8 9.5 4.6 6.9 0.7 8.8 4.9 341 7 353 165 -2.2 0 -1.9 -2.8 03/03/2007 16:00:00 6.8 0.9 8.8 4.6 6.7 0.9 9.1 4.6 6.8 0.9 9.5 4.6 335 8 334 165 -2.3 0.1 -1.9 -2.6 03/03/2007 16:10:00 7.4 1.1 10.7 5.7 7.4 1.1 11.1 5.3 7.3 1.1 10.7 4.9 337 7 342 165 -2.4 0 -2.1 -2.6 03/03/2007 16:20:00 7.3 0.9 9.5 5.3 6.8 1.3 9.9 3.8 7.4 0.9 9.5 5.3 347 8 340 165 -2.6 0.1 -2.1 -3 03/03/2007 16:30:00 6.6 0.8 9.1 4.9 6 1.2 8.8 3.4 6.6 0.8 8.4 4.6 343 13 330 165 -2.6 0.2 -2.1 -3.3 03/03/2007 16:40:00 7.1 0.6 8.8 5.3 7 0.7 9.1 4.6 7.1 0.6 8.8 5.3 339 9 344 165 -2.6 0.2 -2.4 -3.3 03/03/2007 16:50:00 7.2 1.1 9.9 4.2 7.1 1.1 9.9 3.8 7.1 1.1 9.9 4.2 334 11 340 165 -2.7 0.1 -2.4 -3.3 03/03/2007 17:00:00 7.7 1 9.5 4.9 7.7 1 9.5 4.9 7.7 1 9.9 5.7 335 9 332 165 -2.9 0.1 -2.6 -3.5 03/03/2007 17:10:00 7.5 0.8 9.5 4.9 7.5 0.8 9.5 5.3 7.6 0.8 9.5 5.7 338 7 334 165 -3 0.1 -2.6 -3.5 03/03/2007 17:20:00 7.2 1.3 9.9 4.2 7.2 1.5 10.3 3.4 7.2 1.2 9.9 3.8 343 7 342 165 -3 0 -2.8 -3.3 03/03/2007 17:30:00 7.6 0.8 9.9 5.3 7.6 0.8 9.9 5.7 7.4 0.9 9.9 5.3 331 9 335 165 -3 0 -2.8 -3.3 03/03/2007 17:40:00 7.1 0.8 8.8 5.3 7 0.8 9.1 4.9 7 0.6 8.4 5.7 337 7 339 165 -3 0 -2.8 -3.3 03/03/2007 17:50:00 7.6 0.9 9.9 4.9 7.5 0.9 9.9 4.9 7 1.1 9.9 4.6 330 7 326 165 -3.3 0 -3 -3.5 03/03/2007 18:00:00 7.5 0.9 9.5 4.9 7.4 0.8 9.1 4.9 7.4 0.8 9.1 4.9 331 8 326 165 -3.4 0 -3.3 -3.5 03/03/2007 18:10:00 6.9 1.1 9.1 4.6 6.8 1.1 9.1 4.2 6.4 1 8.8 4.2 336 7 344 165 -3.6 0.1 -3.3 -3.9 03/03/2007 18:20:00 6.3 0.9 8.4 3.8 6.1 1.2 8 2.3 6.3 1 8 3.8 344 9 323 165 -3.9 0 -3.5 -4.2 03/03/2007 18:30:00 5.6 1.2 8 3 5.4 1.3 8.4 3 5.7 1.2 8.4 3.4 342 9 347 165 -4.2 0 -3.9 -4.4 03/03/2007 18:40:00 6.3 0.8 8 4.2 5.4 1.2 8 2.6 6.5 0.9 8 3.8 352 8 344 165 -4.4 0 -4.2 -4.6 03/03/2007 18:50:00 7.1 0.8 8.8 4.9 6.8 1.2 9.1 4.2 7.2 0.8 9.1 5.3 347 6 350 165 -4.3 0 -4.2 -4.6 03/03/2007 19:00:00 7 0.8 8.8 4.6 6.2 1 8.4 3.8 7.2 0.8 8.8 4.9 350 7 357 165 -4.3 0 -4.2 -4.6 03/03/2007 19:10:00 6.5 0.7 8.4 4.9 6.5 0.7 8.8 4.6 6.6 0.7 9.1 4.9 340 8 340 165 -4.4 0 -4.4 -4.6 03/03/2007 19:20:00 6.3 0.8 8.8 4.6 6 1 9.1 3 6.5 0.8 8.8 4.9 347 6 346 165 -4.5 0 -4.4 -4.8 03/03/2007 19:30:00 6.7 0.9 8.4 4.2 6.7 1 8.8 4.2 6.8 1 8.8 4.6 340 9 349 165 -4.4 0 -4.2 -4.6 03/03/2007 19:40:00 5.4 0.9 7.6 3 5.1 0.9 7.2 3 5.5 0.8 7.6 3.4 344 10 358 165 -4.3 0 -4.2 -4.6 03/03/2007 19:50:00 4.8 0.8 7.2 3 4.8 0.9 7.6 2.3 5 0.8 7.2 2.6 337 11 340 165 -4.4 0 -4.2 -4.6 03/03/2007 20:00:00 3.5 0.5 4.9 2.3 3.5 0.5 4.9 2.6 3.6 0.6 4.9 1.9 321 16 330 165 -4.4 0 -4.2 -4.6 03/03/2007 20:10:00 3.8 0.5 4.9 2.6 3.8 0.5 5.3 2.6 3.5 0.7 4.9 1.9 305 11 316 165 -4.4 0.1 -4.2 -4.6 03/03/2007 20:20:00 3.5 0.6 5.3 1.9 3.5 0.6 5.3 2.3 3.7 0.6 4.9 1.9 318 13 302 165 -4.6 0 -4.4 -4.8 03/03/2007 20:30:00 3.9 0.6 5.7 2.6 4 0.6 5.7 2.6 3.9 0.5 5.3 2.6 317 11 310 165 -4.8 0 -4.4 -5 03/03/2007 20:40:00 3.5 0.5 5.3 2.3 3.5 0.5 5.3 2.3 3.5 0.5 4.6 1.9 314 11 302 165 -4.8 0.1 -4.6 -5 03/03/2007 20:50:00 4.1 0.5 5.3 2.3 4.1 0.5 5.3 2.6 3.7 0.6 5.3 2.3 306 12 305 165 -4.8 0 -4.4 -5 03/03/2007 21:00:00 4 0.6 6.1 2.3 4.1 0.6 6.1 2.3 3.9 0.7 6.1 2.3 314 12 316 165 -4.5 0 -4.2 -4.6 03/03/2007 21:10:00 4.1 0.7 6.1 2.6 4.1 0.6 5.7 2.3 4.3 0.6 6.5 3 329 11 316 165 -4.4 0 -4.2 -4.6 03/03/2007 21:20:00 3.7 0.8 5.3 2.3 3.7 0.8 5.3 2.3 3.9 0.6 5.7 2.3 331 8 319 165 -4.3 0 -3.9 -4.6 03/03/2007 21:30:00 3.7 0.6 5.7 2.6 3.8 0.6 5.7 2.3 3.8 0.6 5.3 2.3 322 15 310 165 -4.3 0 -3.9 -4.6 03/03/2007 21:40:00 4.5 0.4 5.7 3.4 4.5 0.4 5.7 3.4 4.5 0.5 5.7 2.6 329 10 309 165 -4.4 0 -4.2 -4.6 03/03/2007 21:50:00 4.2 0.4 5.3 3 4.3 0.4 5.7 3.4 4.5 0.4 5.7 3.8 329 7 328 165 -4.8 0 -4.6 -5 03/03/2007 22:00:00 4.3 0.5 5.3 3 4.4 0.5 5.3 3 4.3 0.5 5.3 3.4 337 7 336 165 -5 0 -4.8 -5.3 03/03/2007 22:10:00 3.8 0.4 4.9 2.6 3.9 0.4 4.9 2.6 3.7 0.4 4.6 2.6 338 6 334 165 -4.9 0.1 -4.6 -5.3 03/03/2007 22:20:00 3.4 0.5 4.6 2.3 3.5 0.5 4.9 2.3 3.2 0.4 4.2 2.3 325 15 296 165 -4.7 0 -4.6 -4.8 03/03/2007 22:30:00 3.5 0.5 4.9 2.3 3.6 0.5 4.6 2.3 3.6 0.5 5.3 2.3 315 7 314 165 -4.4 0.1 -4.2 -4.8 03/03/2007 22:40:00 2.8 0.6 4.2 1.1 2.9 0.6 4.2 1.5 2.9 0.4 3.8 1.9 315 11 309 165 -4.3 0.1 -3.9 -4.6 03/03/2007 22:50:00 2.3 0.4 3 1.1 2.4 0.4 3.4 1.1 2.5 0.3 3.4 1.5 317 9 321 165 -3.9 0 -3.7 -4.2 03/03/2007 23:00:00 2.9 0.3 3.8 2.3 3 0.3 3.8 2.3 2.6 0.4 3.8 1.5 302 5 300 165 -4.1 0 -3.9 -4.4 03/03/2007 23:10:00 3.2 0.4 4.2 2.3 3.3 0.4 4.2 1.9 2.8 0.5 4.2 1.5 301 6 308 165 -4.3 0 -3.9 -4.6 03/03/2007 23:20:00 3.1 0.5 4.6 1.9 3.2 0.5 4.2 1.9 2.7 0.4 3.8 1.9 304 5 302 165 -4.3 0 -4.2 -4.6 03/03/2007 23:30:00 2.8 0.3 3.4 1.9 2.9 0.3 3.8 2.3 2.3 0.3 3.4 1.5 299 5 298 165 -4.2 0 -3.9 -4.4 03/03/2007 23:40:00 1.9 0.6 3.4 0.7 2.2 0.5 3.4 1.1 2.2 0.5 3.8 1.1 291 7 292 165 -4 0 -3.7 -4.4 03/03/2007 23:50:00 1.8 0.3 2.6 1.1 2 0.3 2.6 1.1 2 0.4 3.4 1.1 299 6 297 165 -3.8 0 -3.5 -3.9 03/04/2007 00:00:00 1.9 0.4 3 1.1 2.1 0.4 3.4 1.1 2.3 0.5 3.8 1.5 293 6 288 165 -4 0 -3.7 -4.2 03/04/2007 00:10:00 2.4 0.6 3.4 0.7 2.5 0.6 3.8 0.7 2.2 0.4 3.4 1.1 296 7 307 165 -4 0.1 -3.9 -4.4 03/04/2007 00:20:00 1.8 0.4 2.6 0.4 1.9 0.4 2.6 0.4 1.8 0.3 2.6 0.7 294 6 302 165 -4.1 0 -3.9 -4.6 03/04/2007 00:30:00 1.7 0.4 2.6 0.7 1.9 0.4 2.6 0.7 1.9 0.4 3 1.1 295 5 295 165 -3.8 0 -3.5 -4.2 03/04/2007 00:40:00 0.9 0.6 2.6 0.4 1.3 0.5 2.6 0.4 1.7 0.3 2.3 1.1 290 7 292 165 -3.7 0 -3.5 -3.9 03/04/2007 00:50:00 0.7 0.4 1.5 0.4 1.3 0.5 2.3 0.4 1.5 0.4 2.6 0.7 284 10 282 165 -3.6 0 -3.5 -3.9 03/04/2007 01:00:00 0.4 0 0.4 0.4 0.5 0.2 1.1 0.4 0.8 0.3 1.5 0.4 275 7 165 165 -3.5 0 -3.3 -3.7 03/04/2007 01:10:00 0.4 0 0.4 0.4 0.5 0.2 1.1 0.4 0.7 0.3 1.1 0.4 283 0 165 165 -3.5 0 -3.3 -3.5 03/04/2007 01:20:00 0.4 0 0.4 0.4 0.4 0 0.7 0.4 0.5 0.2 1.1 0.4 260 18 165 165 -3.5 0 -3.3 -3.5 03/04/2007 01:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0.2 1.1 0.4 243 0 165 165 -3.6 0 -3.5 -3.5 03/04/2007 01:40:00 0.4 0 0.4 0.4 0.9 0.3 1.5 0.4 1.1 0.2 1.5 0.7 275 13 165 165 -3.6 0 -3.5 -3.7 03/04/2007 01:50:00 1.4 0.4 2.3 0.4 1.9 0.4 2.6 0.7 1.6 0.3 2.3 0.7 292 8 297 165 -3.8 0 -3.5 -3.9 03/04/2007 02:00:00 1.9 0.4 3 1.1 2.2 0.4 3 1.5 1.7 0.3 2.6 1.1 300 4 290 165 -3.9 0.1 -3.5 -4.2 03/04/2007 02:10:00 2.3 0.3 3 1.5 2.5 0.3 3 1.5 2 0.3 2.6 1.1 296 3 294 165 -4.2 0 -3.9 -4.4 03/04/2007 02:20:00 2.1 0.4 3 1.1 2.3 0.3 3 1.1 2.1 0.4 3 1.5 291 5 295 165 -4 0 -3.7 -4.4 03/04/2007 02:30:00 2.2 0.4 3.4 1.1 2.4 0.4 3.4 1.5 2.3 0.4 3 1.1 287 6 290 165 -3.9 0 -3.9 -4.2 03/04/2007 02:40:00 2.9 0.5 4.2 1.9 3 0.4 3.8 1.9 2.5 0.5 3.8 1.5 296 4 290 165 -4.2 0 -3.9 -4.4 03/04/2007 02:50:00 2.3 0.3 3 1.5 2.5 0.3 3 1.9 2.2 0.4 3.4 1.1 301 6 301 165 -4 0 -3.9 -4.4 03/04/2007 03:00:00 1.8 0.3 2.6 1.1 2.2 0.2 2.6 1.5 2.4 0.3 3 1.1 335 7 321 165 -4.2 0 -3.9 -4.4 03/04/2007 03:10:00 1.9 0.6 3.4 0.4 2.3 0.5 4.2 1.1 2.3 0.5 3.8 1.1 317 20 298 165 -4.4 0.1 -4.2 -4.6 03/04/2007 03:20:00 1.8 0.7 4.2 0.4 2.2 0.6 4.6 0.4 2.2 0.6 4.2 0.7 316 16 329 165 -4.3 0.1 -3.9 -4.6 03/04/2007 03:30:00 3.3 0.7 5.3 1.5 3.3 0.7 5.3 1.5 3.5 0.6 5.3 2.3 335 17 349 165 -4.8 0 -4.6 -5 03/04/2007 03:40:00 3.1 0.7 4.9 1.1 2.9 0.7 4.9 1.1 3.4 0.5 4.6 1.9 349 14 347 165 -4.8 0 -4.6 -5 03/04/2007 03:50:00 3 0.8 4.9 1.5 3 0.6 4.6 1.5 3.3 0.8 5.3 1.1 340 11 359 165 -4.9 0 -4.6 -5 03/04/2007 04:00:00 3.3 1.1 6.1 1.5 3.4 1.1 6.1 1.5 3.4 0.9 6.1 1.9 325 15 312 165 -4.9 0.2 -4.6 -5.3 03/04/2007 04:10:00 5.8 0.4 6.8 4.6 5.8 0.4 6.8 4.6 5.7 0.4 6.5 4.2 317 5 315 165 -5.3 0 -5 -5.5 03/04/2007 04:20:00 5.2 0.7 6.8 3.4 5.2 0.6 6.8 3 5 0.7 6.8 3.4 314 8 336 165 -5.2 0 -5 -5.5 03/04/2007 04:30:00 5.1 0.7 7.2 3 5.1 0.7 7.2 3.4 5 0.7 6.8 3 327 13 343 165 -5.2 0.1 -4.8 -5.3 03/04/2007 04:40:00 6.8 1 9.1 4.6 6.7 1 9.1 4.2 6.5 1 8.8 4.2 333 7 340 165 -5.3 0 -5 -5.5 03/04/2007 04:50:00 6.7 1.3 9.1 4.2 6.6 1.3 9.1 4.2 6.7 1.3 9.1 4.2 330 7 336 165 -5.1 0.2 -4.6 -5.7 03/04/2007 05:00:00 3.8 0.9 6.5 2.3 3.9 0.9 6.8 2.3 3.4 1.1 6.1 1.1 310 9 310 165 -4.8 0 -4.6 -5 03/04/2007 05:10:00 3.4 1.1 4.9 0.4 3.5 1 4.9 0.7 2.9 0.7 4.9 1.1 303 7 297 165 -4.7 0.1 -4.4 -5 03/04/2007 05:20:00 3.6 0.6 4.9 2.3 3.6 0.5 4.9 2.3 3.5 0.5 4.9 2.3 315 7 310 165 -4.7 0 -4.4 -4.8 03/04/2007 05:30:00 3.3 0.6 4.9 1.9 3.3 0.6 4.6 1.5 3.3 0.5 4.6 1.5 326 15 326 165 -4.9 0 -4.6 -5 03/04/2007 05:40:00 2.8 0.6 4.2 1.1 2.8 0.5 4.2 1.5 2.7 0.6 4.2 1.5 318 15 321 165 -4.9 0 -4.6 -5.3 03/04/2007 05:50:00 2.9 0.7 4.6 1.5 2.6 0.8 4.6 0.4 3.2 0.7 5.3 1.9 7 19 354 165 -5 0 -4.8 -5.3 03/04/2007 06:00:00 3.6 0.6 4.9 2.3 2.4 0.7 4.6 1.1 4.1 0.5 5.7 2.6 3 9 7 165 -5.2 0.1 -4.8 -5.3 03/04/2007 06:10:00 4.8 0.7 6.8 3.4 4.6 0.9 7.2 1.9 4.9 0.7 6.8 3.4 342 8 342 165 -5.3 0 -5 -5.5 03/04/2007 06:20:00 4.8 0.6 6.1 3.4 4.6 0.9 6.1 1.9 4.7 0.6 6.5 3.4 340 12 340 165 -5.4 0 -5.3 -5.7 03/04/2007 06:30:00 3.3 0.4 4.6 1.9 2.4 0.6 4.2 0.7 3.6 0.4 4.6 2.6 0 9 0 165 -5.5 0 -5.3 -5.7 03/04/2007 06:40:00 3.3 0.5 4.9 2.3 3.1 0.6 4.6 1.5 3.8 0.6 5.3 2.3 12 19 26 165 -5.6 0 -5.5 -5.9 03/04/2007 06:50:00 4.4 0.6 5.7 3 3.6 0.8 5.7 1.9 4.6 0.6 6.5 3 10 9 19 165 -5.7 0 -5.5 -5.7 03/04/2007 07:00:00 5.1 0.6 6.5 3.8 3.6 0.9 6.1 1.9 5.3 0.6 6.8 4.2 4 8 22 165 -5.8 0 -5.5 -5.9 03/04/2007 07:10:00 4.5 0.5 5.7 3 3.1 0.6 4.9 1.9 4.9 0.5 6.1 3.8 8 5 15 165 -5.8 0 -5.5 -5.9 03/04/2007 07:20:00 4.7 0.6 6.5 3 3.5 0.9 6.1 1.9 5 0.6 6.8 3.4 0 10 12 165 -5.8 0 -5.7 -6.1 03/04/2007 07:30:00 4.1 0.6 5.3 3 3.9 0.7 5.3 1.9 4.1 0.5 5.3 3 337 15 313 165 -5.9 0 -5.7 -6.1 03/04/2007 07:40:00 2.8 1 6.1 1.1 2.8 1 5.7 0.7 2.9 0.8 5.3 1.5 316 15 328 165 -5.9 0 -5.7 -6.4 03/04/2007 07:50:00 4.7 1.5 8.8 1.9 4.7 1.5 9.5 2.3 4.4 1.3 8.8 2.6 315 12 313 165 -5.9 0 -5.7 -6.1 03/04/2007 08:00:00 5.2 1.2 8.4 3 5.1 1.2 8 3 5.1 1.2 8.4 2.6 326 9 330 165 -6.1 0 -5.7 -6.4 03/04/2007 08:10:00 6.5 1.6 11.1 2.6 6.5 1.6 10.7 3 6.4 1.5 9.5 3 327 12 319 165 -6.2 0 -5.7 -6.4 03/04/2007 08:20:00 6.1 1 8.4 4.2 6.1 1 8 4.2 6.1 1 8.4 3.8 326 8 319 165 -6.1 0 -5.7 -6.4 03/04/2007 08:30:00 7.3 1 9.5 4.9 7.2 0.9 9.5 4.9 7.2 1 9.1 4.6 326 8 332 165 -5.9 0 -5.7 -6.4 03/04/2007 08:40:00 7.6 1 10.3 5.7 7.5 1 10.3 4.6 7.4 1 10.3 5.3 341 9 352 165 -5.8 0.1 -5.5 -6.1 03/04/2007 08:50:00 7.5 1.1 10.3 4.9 7.4 1.1 10.7 4.9 7.1 1.1 9.9 3.8 338 10 351 165 -5.3 0.1 -5 -5.7 03/04/2007 09:00:00 6.7 1.5 10.7 3.4 6 1.7 11.1 2.6 6.4 1.5 9.9 3.8 346 12 350 165 -4.8 0.1 -4.6 -5.3 03/04/2007 09:10:00 6.5 1.2 9.1 3.4 6.2 1.3 9.5 3.4 6.4 1.2 8.8 3.4 341 12 339 165 -4.7 0 -4.4 -4.8 03/04/2007 09:20:00 9.2 1 11.5 6.5 8.4 1.3 11.5 4.2 8.8 1.2 11.5 5.7 344 12 358 165 -4.8 0 -4.6 -5 03/04/2007 09:30:00 10.5 1.2 15.3 8 10.1 1.5 15.3 4.9 10.1 1.3 14.5 7.6 340 9 323 165 -5.4 0.1 -5 -5.7 03/04/2007 09:40:00 10.9 1.3 14.5 8 10.7 1.4 14.1 7.2 10.3 1.3 13.3 7.2 338 9 332 165 -5.3 0.3 -4.6 -5.9 03/04/2007 09:50:00 9.9 1.3 12.6 6.5 9.3 1.8 13 4.9 9.7 1.5 13.3 4.6 344 11 331 165 -4.8 0.1 -4.4 -5 03/04/2007 10:00:00 10.4 1.3 14.5 6.8 9.5 1.8 13.3 4.9 10.1 1.5 16.1 6.1 345 12 9 165 -4.7 0.1 -4.4 -5 03/04/2007 10:10:00 9.8 1.1 13 6.8 9.6 1.3 12.6 4.9 9.6 1.2 13 6.1 340 11 331 165 -4.5 0.1 -4.4 -4.8 03/04/2007 10:20:00 10 1.3 14.9 6.8 9.7 1.5 14.5 6.5 9.8 1.5 15.3 6.8 338 11 340 165 -4.3 0 -3.9 -4.6 03/04/2007 10:30:00 11.9 1.3 15.3 8.8 11.5 1.7 15.6 6.1 11.5 1.5 15.6 7.6 345 8 357 165 -4.3 0 -3.9 -4.6 03/04/2007 10:40:00 9.6 1.5 14.1 6.1 8.9 1.6 14.9 5.3 9.3 1.5 13.7 6.5 343 12 352 165 -4 0.1 -3.9 -4.6 03/04/2007 10:50:00 8.1 1.5 12.2 4.9 7.8 1.7 11.8 3 7.7 1.3 11.5 5.3 341 9 354 165 -3.7 0.2 -3.3 -4.4 03/04/2007 11:00:00 7 1.4 10.7 4.2 6.2 1.5 10.3 3 6.8 1.4 10.7 4.6 344 13 318 165 -3.2 0.1 -2.8 -3.5 03/04/2007 11:10:00 7.1 1.3 10.7 4.6 6.4 1.5 11.1 3 7 1.3 10.7 4.2 343 19 318 165 -3.8 0.2 -3.3 -4.4 03/04/2007 11:20:00 10.7 2.5 16.8 5.7 10.3 2.7 16.8 3.8 10.4 2.4 15.6 5.7 333 13 316 165 -3.9 0.5 -3.3 -4.8 03/04/2007 11:30:00 12.8 1.9 18.3 8 12.7 1.9 17.6 8 12.6 2 17.2 8 334 8 317 165 -4.5 0.2 -4.2 -5 03/04/2007 11:40:00 13.2 1.7 17.6 8.8 13 1.9 17.2 7.6 13 1.7 17.2 9.1 339 8 331 165 -4.3 0.1 -3.9 -4.8 03/04/2007 11:50:00 13.2 1.5 18.7 9.5 12.7 1.7 18.7 7.6 13.1 1.6 17.6 9.5 343 8 344 165 -4 0.1 -3.7 -4.6 03/04/2007 12:00:00 10.1 1.8 15.3 6.1 9.9 1.8 16.1 4.9 9.7 1.7 14.9 6.1 329 13 309 165 -3.7 0.2 -3.3 -4.6 03/04/2007 12:10:00 9.4 2 13.3 6.1 9.1 2.1 13.7 3.4 8.9 1.9 13.3 5.7 330 13 330 165 -3.6 0.3 -3 -4.4 03/04/2007 12:20:00 10.3 1.5 14.1 6.8 10.1 1.5 13.7 6.1 9.5 1.7 14.1 5.7 326 10 323 165 -3.6 0.3 -3 -4.4 03/04/2007 12:30:00 12.8 1.5 16.4 8 12.6 1.5 16.4 8.4 12.3 1.5 16.8 7.6 338 8 343 165 -3.4 0.1 -3 -3.9 03/04/2007 12:40:00 13.3 1.6 16.8 8 13.1 1.6 16.4 6.5 12.9 1.7 16.8 8 333 10 339 165 -3.7 0.1 -3.3 -4.2 03/04/2007 12:50:00 13.8 1.7 17.9 9.1 13.7 1.7 17.6 7.6 13.3 1.7 17.9 7.2 330 11 323 165 -3.7 0.1 -3.5 -4.4 03/04/2007 13:00:00 14 1.3 17.2 9.9 13.7 1.5 17.2 8 13.1 1.5 16.4 9.5 338 7 332 165 -3.7 0.1 -3.3 -3.9 03/04/2007 13:10:00 13.1 1.6 16.8 8.4 13 1.6 16.4 8 12.2 1.8 16.1 6.8 337 8 338 165 -3.4 0.1 -3.3 -3.9 03/04/2007 13:20:00 12.7 1.5 16.8 8 12.2 1.8 16.4 5.7 12.3 1.5 16.4 7.2 337 11 337 165 -3.6 0.1 -3.3 -4.2 03/04/2007 13:30:00 11.7 1.7 16.1 8 11.3 1.7 15.6 5.7 11.1 1.8 16.1 7.2 332 15 319 165 -3.5 0.3 -2.8 -4.4 03/04/2007 13:40:00 13.1 2.6 18.7 7.6 12.7 2.7 19.1 5.7 12.5 2.6 18.3 8 334 10 333 165 -3.7 0.1 -3.3 -4.2 03/04/2007 13:50:00 13.5 2 17.9 8 13.3 1.8 17.6 8.4 12.8 2.1 17.9 8 331 11 339 165 -3.6 0.1 -3.3 -4.2 03/04/2007 14:00:00 13.1 2.3 19.1 6.8 12.9 2.3 18.3 7.2 12.1 2.8 19.1 4.9 324 10 322 165 -3.9 0.2 -3.3 -4.4 03/04/2007 14:10:00 14.1 2.5 19.9 7.2 13.9 2.6 19.9 5.7 13.7 2.6 19.1 6.8 333 9 340 165 -4 0.2 -3.5 -4.6 03/04/2007 14:20:00 14.9 2.2 20.2 8.4 14.6 2.5 19.5 4.9 14.7 2.3 20.2 9.1 337 11 319 165 -4 0.1 -3.7 -4.6 03/04/2007 14:30:00 16.6 2.4 23.3 10.3 16.3 2.4 22.6 8 16.4 2.5 21.8 9.9 335 9 338 165 -4.1 0.1 -3.7 -4.6 03/04/2007 14:40:00 17.3 1.9 21.4 12.2 16.9 2.2 21 9.9 16.7 2.1 21.4 11.5 336 8 332 165 -4.2 0.1 -3.9 -4.6 03/04/2007 14:50:00 18.1 1.8 21.8 12.2 17.9 1.9 21.4 11.1 17.6 1.9 22.1 11.5 335 6 338 165 -4.2 0.1 -3.9 -4.6 03/04/2007 15:00:00 18.7 1.6 22.1 13.3 18.5 1.8 21.8 11.1 18.3 1.7 21.8 13 339 7 334 165 -4.2 0.1 -3.9 -4.6 03/04/2007 15:10:00 18.2 1.8 23.3 12.2 17.9 1.8 23.3 11.8 17.7 2.1 23.7 12.2 335 7 325 165 -4.2 0 -3.9 -4.8 03/04/2007 15:20:00 16.8 1.6 22.6 12.2 16.5 2 22.6 9.1 16.5 1.8 21 11.1 336 10 341 165 -4.2 0.1 -3.9 -4.6 03/04/2007 15:30:00 14.4 2.5 20.2 9.5 14.2 2.3 19.9 9.1 14 2.5 21 9.1 330 9 326 165 -4.4 0.2 -3.9 -4.6 03/04/2007 15:40:00 15 2.1 20.6 11.1 14.9 2 19.9 10.7 14.6 2.4 20.6 7.6 332 11 332 165 -4.6 0.1 -4.4 -5 03/04/2007 15:50:00 14.5 1.7 22.9 10.7 14.3 1.7 22.1 10.3 13.9 1.8 22.1 10.3 326 10 331 165 -4.4 0.1 -4.2 -4.6 03/04/2007 16:00:00 13.9 2.3 18.7 8 13.6 2.4 18.3 7.6 13.6 2.3 18.7 8 337 12 340 165 -4.5 0.1 -4.2 -4.8 03/04/2007 16:10:00 13.8 2.4 19.5 9.1 13.5 2.3 18.7 8 13.5 2.3 19.1 8.4 330 9 330 165 -4.5 0.2 -4.2 -4.8 03/04/2007 16:20:00 10.1 1.5 15.3 6.8 9.9 1.5 15.3 6.1 9.7 1.7 16.4 6.5 330 10 328 165 -4.3 0.2 -3.9 -4.6 03/04/2007 16:30:00 13.8 1.6 17.9 9.1 13.6 1.6 17.6 9.1 13.2 1.8 19.1 7.6 325 11 325 165 -4.6 0.2 -3.9 -5 03/04/2007 16:40:00 13.7 2.5 20.6 7.6 13.3 2.7 21.4 5.3 13.4 2.5 21 7.6 332 13 333 165 -4.8 0.1 -4.6 -5 03/04/2007 16:50:00 13.5 2 18.3 7.2 13.3 2 18.3 6.8 13.3 2 17.9 7.2 333 9 324 165 -4.8 0 -4.6 -5 03/04/2007 17:00:00 15.3 1.8 19.5 11.1 15.2 1.8 19.5 10.7 15.1 1.7 19.5 10.7 337 8 334 165 -5 0 -4.6 -5.3 03/04/2007 17:10:00 16 2.2 21.4 11.1 15.8 2.1 21 10.7 15.7 2.2 21.8 11.1 332 6 334 165 -5.1 0.1 -4.8 -5.3 03/04/2007 17:20:00 13.9 2.3 19.5 6.5 13.7 2.4 19.5 5.7 14 2.4 19.9 6.5 331 9 343 165 -5.4 0 -5.3 -5.7 03/04/2007 17:30:00 12.2 1.9 16.8 6.1 11.8 2 16.8 5.7 11.9 1.9 17.2 7.2 332 13 323 165 -5.4 0 -5.3 -5.7 03/04/2007 17:40:00 12.3 1.8 17.6 8.4 12.1 1.9 17.6 7.6 12.1 1.8 18.7 8.8 333 11 332 165 -5.4 0 -5.3 -5.7 03/04/2007 17:50:00 14.4 2.2 19.5 8.8 14.3 2.3 18.3 7.2 14.2 2.3 18.7 8.8 337 9 356 165 -5.6 0.1 -5.5 -5.9 03/04/2007 18:00:00 13.5 1.7 19.5 9.9 13.3 1.7 19.5 9.9 13 1.7 17.9 8.8 332 10 291 165 -6 0.1 -5.5 -6.4 03/04/2007 18:10:00 15.5 2 19.9 10.7 15.1 2 19.1 9.1 15.2 2.1 19.9 10.7 334 8 329 165 -6.2 0.1 -5.9 -6.6 03/04/2007 18:20:00 13.4 2.2 17.6 8 13.1 2.2 17.9 8 12.8 2.3 17.6 7.2 335 13 324 165 -6.4 0 -6.1 -6.6 03/04/2007 18:30:00 15.2 2.3 20.6 9.5 15.1 2.3 20.2 9.1 14.9 2.5 20.2 8 333 8 328 165 -6.4 0 -6.4 -6.6 03/04/2007 18:40:00 9.4 2.5 15.3 2.3 9.1 2.5 15.6 1.9 8.5 2.6 14.9 2.3 331 19 323 165 -6.6 0 -6.6 -6.8 03/04/2007 18:50:00 12.6 1.5 17.2 8.8 12.3 1.7 17.2 7.6 11.9 1.7 16.4 8 338 10 336 165 -6.7 0 -6.6 -6.8 03/04/2007 19:00:00 12.6 1.6 16.4 8.4 12.3 1.7 16.4 8 12 1.6 16.4 7.6 335 9 334 165 -6.8 0 -6.6 -6.8 03/04/2007 19:10:00 10.7 1.7 15.3 6.5 10.3 2.1 16.1 5.3 10.3 1.8 14.9 6.1 339 10 346 165 -6.9 0.1 -6.6 -7 03/04/2007 19:20:00 10.2 1.4 16.1 6.5 10 1.4 16.4 6.5 9.6 1.4 13.7 6.1 331 12 355 165 -7.1 0 -6.8 -7.2 03/04/2007 19:30:00 11.9 2.9 20.6 6.5 11.5 3.1 20.6 6.5 11.1 2.9 20.6 6.1 337 11 336 165 -7.2 0 -7 -7.4 03/04/2007 19:40:00 14.5 2.6 20.2 8.4 14.3 2.6 20.2 8 14.2 2.5 20.2 8 334 10 334 165 -7.3 0 -7.2 -7.6 03/04/2007 19:50:00 18.5 1.3 21.4 14.9 18.5 1.5 22.1 13 17.9 1.5 21.8 13.7 339 7 338 165 -7.3 0 -7.2 -7.4 03/04/2007 20:00:00 16.5 2.4 22.6 10.3 16.3 2.5 22.1 9.9 16.4 2.5 21.8 9.9 333 9 338 165 -7.2 0 -6.8 -7.4 03/04/2007 20:10:00 14.3 2.4 22.6 8.8 13.7 2.7 23.7 7.2 14.2 2.5 21.8 8 334 13 347 165 -7.1 0 -6.8 -7.4 03/04/2007 20:20:00 13.5 3.2 20.6 6.5 13.2 3.3 20.6 5.7 13.5 3.3 20.6 6.5 337 13 347 165 -7.2 0 -7 -7.4 03/04/2007 20:30:00 14.5 2.3 22.6 8 14 2.6 21.8 8 14.5 2.4 19.5 8.4 338 10 334 165 -7.2 0 -7 -7.4 03/04/2007 20:40:00 14 1.8 20.2 9.5 13.7 2.1 21.4 8 13.8 1.9 21 8.8 335 11 338 165 -7.2 0 -7 -7.4 03/04/2007 20:50:00 14.8 2.7 21 8.4 14.5 2.8 21 7.6 14.6 2.9 20.6 7.2 335 11 338 165 -7.3 0 -7.2 -7.4 03/04/2007 21:00:00 15.3 2.1 21.8 10.7 15.1 2.2 21.8 9.9 14.7 2.5 22.6 9.1 335 9 333 165 -7.5 0 -7.2 -7.6 03/04/2007 21:10:00 17.1 1.6 21 13 16.6 1.7 20.6 10.7 16 1.7 20.2 11.5 338 9 334 165 -7.5 0 -7.4 -7.6 03/04/2007 21:20:00 15.8 1.7 22.6 11.5 15.5 1.7 22.1 11.1 14.7 1.8 19.9 10.7 335 9 326 165 -7.5 0 -7.4 -7.6 03/04/2007 21:30:00 17.2 1.7 21.8 12.6 17.1 1.7 21.4 11.8 16.8 1.9 22.1 11.1 335 8 325 165 -7.4 0 -7.2 -7.9 03/04/2007 21:40:00 16 1.7 20.2 11.1 15.5 2.3 20.6 8.8 16.2 1.8 20.6 12.2 337 12 344 165 -7.3 0 -7.2 -7.4 03/04/2007 21:50:00 12.5 1.6 17.2 8.4 12.4 1.6 16.8 7.6 12.4 1.8 16.8 7.2 332 12 332 165 -7.4 0 -7.2 -7.6 03/04/2007 22:00:00 12.7 1.7 17.2 8.8 12.2 1.7 16.8 7.6 12.3 1.8 17.6 7.6 332 12 323 165 -7.5 0 -7.2 -7.6 03/04/2007 22:10:00 15.5 2 21 10.7 15.2 2.1 20.6 9.5 15.5 2.1 22.9 10.3 335 8 334 165 -7.3 0 -7.2 -7.4 03/04/2007 22:20:00 15.8 2 21.8 11.1 15.6 2.2 21 8 15.9 2.1 21.4 11.1 336 8 330 165 -7.2 0 -7 -7.4 03/04/2007 22:30:00 13.8 2.2 18.3 7.6 13.6 2.3 19.1 8 13.7 2.2 19.1 7.6 337 8 337 165 -7.3 0 -7.2 -7.6 03/04/2007 22:40:00 13.3 1.6 17.2 8.4 12.7 1.8 16.4 7.6 13.4 1.7 18.3 9.1 339 10 360 165 -7.3 0 -7.2 -7.4 03/04/2007 22:50:00 10.7 1.5 14.9 7.6 10.6 1.5 15.3 6.8 10.7 1.5 15.3 7.2 335 10 329 165 -7.4 0 -7.2 -7.4 03/04/2007 23:00:00 12.5 2.3 17.9 7.6 12.3 2.4 18.3 7.2 12.5 2.4 19.1 7.6 333 11 326 165 -7.3 0 -7 -7.4 03/04/2007 23:10:00 13 1.9 17.6 8.8 12.8 2.1 17.9 6.1 13.1 1.9 17.9 8.4 338 10 328 165 -7.2 0 -7.2 -7.4 03/04/2007 23:20:00 13.9 2 18.3 8.8 13.3 2.4 18.3 7.2 13.7 2 19.5 9.1 340 12 353 165 -7.3 0 -7.2 -7.6 03/04/2007 23:30:00 13 2.5 19.5 7.2 12.8 2.5 20.2 7.2 12.9 2.6 19.5 7.2 327 11 339 165 -7.2 0 -7 -7.4 03/04/2007 23:40:00 11.2 2.1 17.2 7.2 10.9 2.2 18.3 6.8 10.9 2.3 17.2 6.8 328 14 344 165 -7.4 0 -7.2 -7.4 03/04/2007 23:50:00 14.7 2.4 19.9 8 14.2 2.6 19.1 6.5 14.6 2.4 19.5 8 334 11 329 165 -7.3 0 -7.2 -7.4 03/05/2007 00:00:00 14.6 1.6 19.9 9.1 14.3 1.7 19.5 8.8 14.4 1.7 21.8 10.7 335 10 338 165 -7.3 0 -7.2 -7.4 03/05/2007 00:10:00 13.2 2.1 17.6 6.5 12.9 2.2 17.6 7.2 12.8 2.2 17.2 6.1 333 11 339 165 -7.4 0 -7.2 -7.4 03/05/2007 00:20:00 14.6 2.3 18.7 7.2 14.5 2.3 18.3 7.2 14.6 2.6 19.9 6.5 332 10 330 165 -7.4 0 -7.2 -7.4 03/05/2007 00:30:00 12.6 2 18.3 8 12.3 2.1 17.6 6.8 12.3 1.9 17.9 6.8 333 13 326 165 -7.4 0 -7.2 -7.4 03/05/2007 00:40:00 11.9 2 16.8 8 11.6 2.1 17.6 8 11.7 2.1 17.6 8 331 11 344 165 -7.5 0 -7.2 -7.6 03/05/2007 00:50:00 15.6 2.7 21.8 9.9 15.3 2.8 22.1 8 15.3 2.8 22.1 8 336 10 339 165 -7.4 0 -7.2 -7.6 03/05/2007 01:00:00 14.7 2.1 20.6 8 14.6 2.2 20.2 7.2 14.7 2.4 19.5 7.6 332 11 332 165 -7.5 0 -7.2 -7.6 03/05/2007 01:10:00 15 2.1 20.6 9.9 14.8 2.1 20.2 8 14.7 2.2 19.9 9.5 333 8 330 165 -7.5 0 -7.2 -7.6 03/05/2007 01:20:00 13.9 1.9 18.3 9.5 13.4 2.3 17.9 7.2 13.7 2.1 19.5 9.1 334 12 336 165 -7.5 0 -7.4 -7.6 03/05/2007 01:30:00 15.7 2.1 19.5 9.5 15.5 2.1 19.1 9.9 15.7 2.1 19.5 10.7 331 8 334 165 -7.5 0 -7.4 -7.6 03/05/2007 01:40:00 15 2.8 22.1 8.8 15 2.8 22.1 9.1 15 2.9 21.4 8.4 333 8 342 165 -7.6 0 -7.4 -7.9 03/05/2007 01:50:00 14.1 1.8 18.7 7.6 14 1.9 17.9 7.6 14.1 2 19.9 7.2 333 11 322 165 -7.7 0 -7.6 -8.1 03/05/2007 02:00:00 15.8 1.8 20.2 9.9 15.8 1.9 19.9 9.1 15.7 2 19.5 8.8 335 8 330 165 -7.9 0 -7.6 -8.1 03/05/2007 02:10:00 16 2.2 22.6 10.3 15.4 2.7 22.6 7.6 16.2 2.4 21.8 8.4 343 10 350 165 -7.9 0 -7.6 -8.1 03/05/2007 02:20:00 13.5 1.7 17.2 9.5 13.1 1.7 17.6 9.5 13.6 1.8 18.3 9.5 337 11 350 165 -8 0 -7.6 -8.1 03/05/2007 02:30:00 13.8 2.5 19.9 8.8 13.3 2.7 19.5 6.5 13.9 2.6 19.5 9.1 336 12 327 165 -8 0 -7.9 -8.1 03/05/2007 02:40:00 13.4 2.7 19.5 7.2 13.1 2.9 19.9 7.2 13.3 2.7 19.9 8.4 337 12 348 165 -8 0 -7.9 -8.1 03/05/2007 02:50:00 15.4 2.7 21.4 8.4 15 2.8 21.4 8.4 15.4 2.8 21.8 8.8 340 9 353 165 -8 0 -8.1 -8.1 03/05/2007 03:00:00 13.1 2.2 17.6 7.6 12.6 2.3 17.9 6.5 13.1 2.6 19.1 6.8 335 16 343 165 -8.1 0 -8.1 -8.3 03/05/2007 03:10:00 11.2 2.1 19.5 6.5 10.7 1.8 17.2 5.7 11.1 2.3 20.2 6.5 332 16 6 165 -8.1 0 -8.1 -8.3 03/05/2007 03:20:00 13.3 2.9 21.4 7.2 13 3.1 21 6.5 13 3.1 21.4 5.7 332 16 336 165 -8.2 0 -8.1 -8.5 03/05/2007 03:30:00 17 2.5 22.6 11.5 16.7 2.6 21.8 8.4 16.7 2.6 22.9 10.3 335 9 344 165 -8.2 0 -8.1 -8.5 03/05/2007 03:40:00 18.2 1.8 21.8 11.5 17.9 2.2 22.6 11.5 18.1 1.9 22.1 11.8 338 8 345 165 -8.3 0 -8.1 -8.5 03/05/2007 03:50:00 16.8 2.1 23.7 12.6 16.5 2.6 24.8 9.1 17 2.1 24 11.8 341 9 340 165 -8.5 0.1 -8.3 -8.5 03/05/2007 04:00:00 16.6 2.7 22.1 9.5 16.3 2.7 22.1 9.9 16.5 2.9 22.9 8.8 339 9 335 165 -8.6 0 -8.5 -8.7 03/05/2007 04:10:00 15.2 3.6 22.1 9.1 14.9 3.6 22.1 9.1 15.4 3.6 23.7 8 331 10 332 165 -8.7 0 -8.5 -8.9 03/05/2007 04:20:00 19.8 2.3 25.2 14.1 19.6 2.5 24.8 11.5 19.8 2.4 25.6 13.3 333 8 335 165 -8.7 0 -8.5 -8.9 03/05/2007 04:30:00 19.2 2.2 25.2 13.3 19.1 2.3 26.3 13.3 19.2 2.1 24 12.6 337 8 338 165 -8.7 0 -8.5 -8.9 03/05/2007 04:40:00 19.9 1.8 24 13.3 19.6 1.9 24 13.3 19.7 2.1 23.7 13.3 337 8 330 165 -8.8 0 -8.7 -9.1 03/05/2007 04:50:00 18.6 2.5 27.1 12.6 18.5 2.8 27.9 12.2 18.6 2.5 26 11.5 338 9 344 165 -8.8 0 -8.7 -8.9 03/05/2007 05:00:00 17.2 2.8 27.1 8.4 16.6 3.3 26.3 6.5 17.2 2.7 24 8.4 338 12 339 165 -8.9 0 -8.7 -9.1 03/05/2007 05:10:00 16.6 2.5 24 11.5 16.4 2.6 25.2 7.6 16.5 2.5 24 11.5 334 10 344 165 -8.9 0 -8.7 -9.1 03/05/2007 05:20:00 14.5 2.7 23.3 8 14.3 2.7 22.9 7.2 14 2.8 21.4 5.3 328 11 355 165 -9 0 -8.9 -9.1 03/05/2007 05:30:00 15 3.3 22.1 8.8 14.9 3.5 22.6 7.6 14.9 3.5 22.9 6.8 332 11 332 165 -9.1 0 -8.9 -9.3 03/05/2007 05:40:00 15.7 2.9 22.6 7.2 15.4 3.1 23.3 6.5 15.4 3.1 24 6.1 332 12 322 165 -9.1 0 -8.9 -9.3 03/05/2007 05:50:00 17.3 2.9 25.2 10.7 16.8 3.3 25.2 8.4 17.3 2.9 24.4 11.1 339 10 321 165 -9.1 0 -9.1 -9.3 03/05/2007 06:00:00 17.7 2.7 26.3 11.1 17.2 3.2 26 8.4 17.9 2.8 26 10.3 336 11 333 165 -9.2 0 -9.1 -9.3 03/05/2007 06:10:00 19.2 2.3 25.6 13.7 18.6 2.6 24 9.9 19 2.4 26.8 13.3 338 12 346 165 -9.2 0 -9.1 -9.3 03/05/2007 06:20:00 16.4 3.1 23.7 8.8 15.7 3.5 24 5.7 16.1 3.2 23.7 9.1 335 14 354 165 -9.3 0 -9.1 -9.5 03/05/2007 06:30:00 12.9 3.1 21.4 7.2 12.4 3.2 21.4 5.7 12.5 3.3 20.6 6.8 332 14 330 165 -9.3 0 -9.1 -9.5 03/05/2007 06:40:00 15.2 3.3 23.7 8 15 3.3 23.3 7.2 14.4 3.6 23.3 7.2 325 13 333 165 -9.3 0 -9.1 -9.7 03/05/2007 06:50:00 16.4 2.7 25.2 9.9 16 2.8 24.8 9.5 16 3.1 25.2 8.8 323 13 332 165 -9.3 0 -9.1 -9.5 03/05/2007 07:00:00 15.8 2.7 21.8 8.4 15.5 3.1 21.4 8 15.6 2.9 24 9.1 331 14 305 165 -9.3 0 -9.3 -9.7 03/05/2007 07:10:00 15.3 3.2 25.2 6.8 15 3.3 24.8 7.2 14.8 3.2 24 7.6 327 14 335 165 -9.4 0 -9.3 -9.5 03/05/2007 07:20:00 14.9 3.3 22.6 7.6 14.7 3.2 22.1 7.6 14.1 3.5 22.1 7.6 321 14 336 165 -9.4 0 -9.3 -9.7 03/05/2007 07:30:00 16.9 3.8 28.7 7.2 16.7 3.8 29.8 7.6 16.3 3.6 29.8 8.4 324 12 307 165 -9.4 0 -9.3 -9.7 03/05/2007 07:40:00 16.1 3.2 25.2 8.8 15.6 3.3 25.2 7.2 15.5 3.2 25.2 6.8 327 17 344 165 -9.5 0 -9.3 -9.7 03/05/2007 07:50:00 18 3.5 27.1 11.1 17.6 3.6 27.1 11.1 17.7 3.5 26.3 9.1 328 15 329 165 -9.5 0 -9.3 -9.7 03/05/2007 08:00:00 16 3.2 23.3 6.5 15.7 3.2 23.3 7.2 15.7 3.3 22.9 8.4 325 13 319 165 -9.6 0 -9.3 -9.7 03/05/2007 08:10:00 16.7 3.1 25.6 9.9 16.5 3.1 25.2 10.3 15.9 2.9 24.8 9.1 325 12 337 165 -9.6 0 -9.3 -9.7 03/05/2007 08:20:00 17.6 3.3 26 10.3 17.4 3.3 25.2 10.3 16.8 3.5 26 8.8 321 14 316 165 -9.6 0 -9.3 -9.7 03/05/2007 08:30:00 15.9 3.1 23.7 8.8 14.8 3.2 21.8 7.6 15.2 3.1 22.6 6.1 344 20 353 165 -9.7 0 -9.5 -10 03/05/2007 08:40:00 17.2 3.5 26 8 16.8 3.6 26 7.6 16.3 4 26.3 6.1 329 21 317 165 -9.6 0 -9.3 -9.7 03/05/2007 08:50:00 17.9 3.2 26 8.8 17.7 3.2 25.6 8.8 17.3 3.2 25.6 8.8 325 11 332 165 -9.4 0 -9.3 -9.7 03/05/2007 09:00:00 16.5 3.2 26 8.4 16.3 3.2 25.6 7.6 15.8 3.2 26 7.2 325 13 316 165 -9.3 0.1 -9.1 -9.7 03/05/2007 09:10:00 19.6 3.5 29.8 9.9 19.4 3.5 29.1 10.3 19.5 3.6 27.9 11.1 331 11 329 165 -9.4 0 -9.1 -9.7 03/05/2007 09:20:00 20.2 3.1 27.5 11.1 20 2.9 26.8 11.1 20.1 3.1 27.1 9.1 326 9 321 165 -9.4 0 -9.1 -9.7 03/05/2007 09:30:00 21.4 3.6 29.4 12.2 21.1 3.6 29.1 11.1 21.2 3.8 34 11.8 328 11 338 165 -9.5 0.2 -9.1 -9.7 03/05/2007 09:40:00 22.8 3.1 30.9 14.9 22.5 3.3 30.2 11.8 22.6 3.2 32.1 14.9 330 11 329 165 -9.5 0.1 -9.3 -9.7 03/05/2007 09:50:00 20.2 4.1 31.8 9.1 19.8 4.1 30.9 9.5 20 4.1 31.8 9.1 330 11 326 165 -9.6 0 -9.3 -10 03/05/2007 10:00:00 22 3.1 29.8 14.1 21.8 3.2 29.8 11.5 21.8 3.3 29.8 12.6 334 10 337 165 -9.6 0 -9.5 -9.7 03/05/2007 10:10:00 22.5 3.3 32.1 13 22.2 3.3 31.8 12.2 22.3 3.5 31.8 13.7 330 9 321 165 -9.6 0 -9.3 -9.7 03/05/2007 10:20:00 21.5 2.9 27.9 12.6 21.2 3.1 27.1 11.5 21.3 3.1 27.9 13 333 9 4 165 -9.5 0 -9.3 -9.7 03/05/2007 10:30:00 19.4 3.3 28.3 11.5 18.8 3.8 27.9 7.6 19.2 3.3 27.9 11.5 330 11 328 165 -9.5 0 -9.3 -9.7 03/05/2007 10:40:00 20.9 2.6 26.8 14.1 20.6 2.7 26.8 12.6 20.6 2.8 27.1 13 328 10 318 165 -9.5 0.1 -9.3 -9.7 03/05/2007 10:50:00 21.5 2.8 28.7 13 21.3 2.8 28.7 13 21.3 2.9 28.7 13.3 332 11 327 165 -9.4 0 -9.1 -9.7 03/05/2007 11:00:00 23.4 2.8 31.3 16.4 23.1 2.8 30.2 16.4 23.2 2.9 30.6 16.4 331 9 332 165 -9.5 0.1 -9.3 -9.7 03/05/2007 11:10:00 24.6 2.7 30.9 17.2 24.4 2.6 30.9 16.8 24.5 2.8 32.4 17.6 328 8 333 165 -9.6 0.1 -9.3 -9.7 03/05/2007 11:20:00 24.6 2.8 31.3 16.8 24.2 2.8 30.9 16.4 24.2 3.1 31.8 16.1 329 8 332 165 -9.4 0.1 -9.1 -9.7 03/05/2007 11:30:00 26.1 2.8 34.4 19.5 25.5 2.9 33.6 16.1 25.7 2.9 34 17.2 334 9 334 165 -9.6 0 -9.3 -9.7 03/05/2007 11:40:00 23.4 2.7 30.6 16.8 22.9 3.1 29.8 13.7 22.5 2.8 30.9 14.9 333 11 326 165 -9.4 0 -9.1 -9.7 03/05/2007 11:50:00 20.5 3.2 27.5 14.1 20.2 3.1 27.1 14.1 19.7 3.2 28.7 11.8 329 9 330 165 -9.4 0.2 -8.9 -9.7 03/05/2007 12:00:00 20.3 2.3 25.6 14.1 19.8 2.4 25.2 12.6 19.6 2.6 26.8 12.6 328 9 325 165 -9.4 0.2 -8.9 -9.7 03/05/2007 12:10:00 20.1 4 29.1 11.5 19.8 4.1 28.7 9.5 19.7 4.1 29.8 11.1 331 9 327 165 -9.3 0.3 -8.7 -9.7 03/05/2007 12:20:00 23.2 2.9 30.6 14.5 23 2.9 30.6 14.5 23 3.1 30.6 13.7 324 9 306 165 -9.5 0.2 -8.9 -10 03/05/2007 12:30:00 21.4 3.3 30.9 14.5 21.1 3.2 29.8 11.1 20.8 3.2 28.7 13.3 330 9 323 165 -9.4 0 -9.3 -9.7 03/05/2007 12:40:00 21.1 3.2 29.8 12.2 20.9 3.2 29.8 10.7 20.4 3.3 27.1 9.1 330 9 333 165 -9.4 0.1 -9.1 -9.7 03/05/2007 12:50:00 20.7 3.1 27.5 10.3 20.1 3.5 26.8 9.1 20 2.9 26.3 11.1 333 11 326 165 -9.4 0.1 -9.1 -9.7 03/05/2007 13:00:00 20.9 3.3 29.4 10.3 20.5 3.3 28.7 10.3 20.2 3.3 29.8 11.5 327 11 332 165 -9.6 0.1 -9.3 -9.7 03/05/2007 13:10:00 21.6 2.7 29.1 14.5 21.1 3.2 30.6 11.8 21.1 2.8 29.1 13.3 331 12 328 165 -9.4 0.2 -9.1 -9.7 03/05/2007 13:20:00 18.4 2.5 24.8 11.5 17.9 2.7 24 9.1 18 2.6 24.8 11.5 329 11 328 165 -9.3 0.1 -9.1 -9.7 03/05/2007 13:30:00 19 2.7 26.8 11.5 18.7 2.9 26.8 9.9 18.6 2.8 26.8 11.1 333 12 330 165 -9.3 0.1 -8.9 -9.5 03/05/2007 13:40:00 19.8 2.5 29.1 13.7 19.6 2.6 28.7 10.3 19.4 2.6 26.8 12.2 336 9 339 165 -9.6 0.1 -9.3 -10 03/05/2007 13:50:00 20.1 2.9 26.3 11.1 19.7 2.8 26 11.8 19.4 3.1 26.3 11.1 330 10 325 165 -9.6 0 -9.3 -9.7 03/05/2007 14:00:00 18.9 2.2 25.2 13.3 18.7 2.3 24.8 13.3 18.2 2.3 25.2 11.5 332 10 333 165 -9.6 0.1 -9.3 -10 03/05/2007 14:10:00 17.6 2.7 26 9.9 17.4 2.7 26.8 9.9 16.5 2.9 24.8 8.4 329 9 347 165 -9.3 0.1 -8.9 -9.7 03/05/2007 14:20:00 17.1 3.2 25.2 9.9 16.7 3.2 24.8 7.2 16.2 3.3 24.8 7.6 331 11 332 165 -9.4 0.1 -9.1 -9.7 03/05/2007 14:30:00 19.1 2.6 26.3 11.5 18.7 2.8 26 10.7 18.7 2.7 25.6 10.3 331 9 319 165 -9.6 0 -9.3 -10 03/05/2007 14:40:00 19.8 2.1 26.3 14.5 19.5 2.3 26.3 12.6 19.1 2.2 25.6 13.3 334 10 313 165 -9.6 0.1 -9.3 -9.7 03/05/2007 14:50:00 20.5 2.7 28.3 13.7 20.3 2.7 28.7 13.7 20 2.6 25.6 11.8 335 9 343 165 -9.7 0.1 -9.3 -10 03/05/2007 15:00:00 19.8 2.7 26.8 11.5 19.5 2.9 26.8 10.3 19.3 2.7 25.6 11.8 335 9 331 165 -9.6 0 -9.3 -10 03/05/2007 15:10:00 20.6 2.2 26.8 15.3 20.3 2.2 26 13.3 20.2 2.3 26.3 14.1 333 8 329 165 -9.7 0 -9.5 -9.7 03/05/2007 15:20:00 19.8 2.8 27.9 11.1 19.6 2.8 28.7 11.8 19.4 2.7 27.1 13.3 333 9 341 165 -9.7 0 -9.3 -10 03/05/2007 15:30:00 21 2.3 26.8 15.3 20.7 2.5 26.3 11.5 20.6 2.3 27.5 14.1 336 8 334 165 -9.7 0.1 -9.3 -10 03/05/2007 15:40:00 21.7 2 27.9 16.4 21.3 2.4 27.5 13.7 21 2.2 26.3 15.3 337 9 334 165 -9.7 0 -9.5 -10 03/05/2007 15:50:00 21.1 2 25.2 15.6 21 2.1 25.6 15.3 20.3 2.3 25.2 14.5 337 7 330 165 -9.7 0 -9.5 -10.2 03/05/2007 16:00:00 21.4 1.8 25.6 14.9 21.3 2.1 25.2 14.5 20.3 2.3 24.8 12.6 338 7 316 165 -9.7 0 -9.3 -10 03/05/2007 16:10:00 20.5 2 25.2 14.5 20.3 2.4 26.3 13 19.9 2.3 25.2 14.5 334 10 344 165 -9.7 0 -9.5 -10 03/05/2007 16:20:00 18.9 2.5 24.8 12.2 18.7 2.5 24.4 11.8 18.3 2.7 24.8 11.1 333 9 322 165 -9.6 0 -9.3 -9.7 03/05/2007 16:30:00 19.7 2.2 24.8 13.3 19.5 2.4 24 12.2 18.8 2.5 24.8 11.5 336 9 338 165 -9.6 0 -9.3 -9.7 03/05/2007 16:40:00 19.4 2 24.8 14.1 19.1 2.1 25.2 13 18.5 2 24.4 13.7 337 9 338 165 -9.7 0 -9.3 -10 03/05/2007 16:50:00 18.8 2 22.9 13 18.7 2.2 23.3 12.2 17.9 2.1 22.6 10.7 335 9 329 165 -9.8 0 -9.5 -10.2 03/05/2007 17:00:00 17.8 2 23.7 13.3 17.4 2.4 25.2 9.9 17 2 22.6 12.2 336 11 346 165 -9.9 0.1 -9.7 -10.2 03/05/2007 17:10:00 18.1 2.5 24 10.7 18 2.5 23.7 10.3 17.5 2.4 22.9 10.3 334 10 318 165 -10.2 0 -10 -10.2 03/05/2007 17:20:00 20.3 1.7 24.4 14.1 20.3 1.8 26.3 13.3 19.2 2.1 25.2 12.6 337 9 345 165 -10.3 0 -10.2 -10.6 03/05/2007 17:30:00 17.1 2.9 22.6 9.5 17 3.1 22.6 8.4 16 3.2 22.1 6.8 337 9 339 165 -10.4 0 -10.2 -10.6 03/05/2007 17:40:00 17.1 2.1 22.6 11.5 16.9 2.2 22.6 10.7 16 2.3 22.1 10.7 337 9 343 165 -10.4 0 -10.2 -10.6 03/05/2007 17:50:00 18.5 1.9 24.4 14.1 18.4 2.1 24.8 13.7 17.5 2.1 22.9 11.8 336 9 340 165 -10.4 0 -10.4 -10.6 03/05/2007 18:00:00 17.9 2.3 22.9 12.2 17.8 2.4 24 12.2 17 2.4 22.1 11.1 336 10 325 165 -10.5 0 -10.4 -10.8 03/05/2007 18:10:00 17.1 2.1 23.7 11.5 16.1 2.7 23.3 8.8 16.5 2.3 22.9 11.1 336 13 326 165 -10.5 0 -10.4 -10.8 03/05/2007 18:20:00 18.4 2.3 24 12.6 18.1 2.4 23.7 10.7 17.4 2.4 22.6 11.8 334 10 333 165 -10.5 0 -10.4 -10.8 03/05/2007 18:30:00 18.1 2.5 23.7 10.7 17.9 2.6 23.3 10.3 16.9 2.7 22.6 10.3 333 10 337 165 -10.6 0 -10.6 -10.8 03/05/2007 18:40:00 19.8 1.8 24.8 15.3 19.8 2.2 26.3 12.2 18.9 1.8 23.3 14.1 339 9 336 165 -10.7 0 -10.6 -10.8 03/05/2007 18:50:00 20 2.1 26 14.5 20 2.3 25.6 14.1 19.2 2.2 24 14.1 338 7 339 165 -10.7 0 -10.6 -11 03/05/2007 19:00:00 20.7 1.9 24.8 15.3 20.9 2.3 26 14.5 20.1 2.2 24.8 13 338 8 336 165 -10.8 0 -10.6 -11 03/05/2007 19:10:00 18.6 2.2 24 12.6 18.5 2.4 25.6 10.7 18 2.4 23.3 11.8 335 9 323 165 -10.8 0 -10.6 -11 03/05/2007 19:20:00 18.6 2.2 24 12.2 18.4 2.6 25.6 11.5 17.5 2.3 22.1 11.1 336 10 331 165 -10.8 0 -10.6 -11 03/05/2007 19:30:00 16.7 2.4 22.9 11.1 16.5 2.5 23.3 9.1 15.6 2.6 21.8 8.4 333 10 329 165 -10.8 0 -10.8 -11 03/05/2007 19:40:00 16.5 2.3 22.1 8.4 16.1 2.4 22.1 8 15.5 2.5 20.2 8 333 11 328 165 -10.9 0 -10.8 -11 03/05/2007 19:50:00 18.1 2 24.8 12.2 17.8 2.2 24 11.5 17 2.1 22.1 10.7 334 11 322 165 -10.9 0 -10.8 -11.2 03/05/2007 20:00:00 14.6 2.3 20.2 7.6 14.3 2.5 19.5 7.2 14.2 2.2 19.9 7.6 334 12 330 165 -10.9 0 -10.8 -11.2 03/05/2007 20:10:00 13.5 2 18.3 8.4 13.3 2 17.9 8.8 12.6 1.8 16.8 9.1 334 11 340 165 -11 0 -11 -11.2 03/05/2007 20:20:00 14.1 2.3 20.6 7.6 13.8 2.5 21.4 7.6 13.3 2.4 18.7 6.8 333 13 341 165 -11 0 -11 -11.4 03/05/2007 20:30:00 15.1 2.3 19.9 8.8 14.7 2.3 20.2 8.8 14.5 2.5 20.6 8 335 12 350 165 -10.9 0 -10.8 -11.2 03/05/2007 20:40:00 16 2.6 24.4 10.3 15.7 2.5 24 10.3 15.4 2.7 24.8 8.8 333 13 326 165 -10.9 0 -10.8 -11 03/05/2007 20:50:00 15.7 2.3 22.1 8.4 15.5 2.3 22.1 8 14.9 2.4 21.4 9.1 334 12 340 165 -10.9 0 -10.8 -11 03/05/2007 21:00:00 13.8 1.9 18.3 8 13.5 1.9 17.9 7.2 13.4 1.8 18.7 8.4 332 11 338 165 -10.9 0 -10.8 -11.2 03/05/2007 21:10:00 15.6 2.4 21.8 8.8 15.2 2.6 22.6 8.8 15.3 2.5 22.9 8.8 334 12 349 165 -10.9 0 -10.8 -11.2 03/05/2007 21:20:00 12.9 2.7 18.7 6.8 12.4 2.9 18.3 6.1 12.5 2.7 19.1 6.5 334 14 321 165 -10.9 0 -10.8 -11.2 03/05/2007 21:30:00 15.5 2.4 22.1 9.9 15.4 2.5 22.1 9.1 15.2 2.5 22.9 9.5 329 11 346 165 -10.9 0 -10.8 -11 03/05/2007 21:40:00 14.4 2.6 21.4 8.8 14.3 2.6 20.6 8.4 14 2.7 20.6 8.8 331 10 330 165 -10.8 0 -10.6 -11 03/05/2007 21:50:00 14.5 2.2 19.9 9.9 14.4 2.3 20.6 9.5 14.3 2.4 21 9.1 329 11 332 165 -10.9 0 -10.8 -11.2 03/05/2007 22:00:00 17.4 1.8 23.7 13 17.4 1.9 24.4 11.1 17 2.1 22.6 11.5 336 8 343 165 -10.8 0 -10.6 -11 03/05/2007 22:10:00 17 1.8 21.8 10.7 16.6 2.2 22.1 11.1 17.2 1.9 21.8 12.6 337 11 344 165 -10.8 0 -10.6 -11 03/05/2007 22:20:00 16.2 2.6 22.1 9.9 16.2 2.6 21.8 9.9 16.1 2.6 22.1 10.3 332 10 317 165 -10.8 0 -10.6 -11 03/05/2007 22:30:00 13.8 2.9 20.6 6.8 13.6 3.1 21.4 6.8 13.6 2.9 20.6 6.8 331 15 336 165 -10.8 0 -10.6 -11 03/05/2007 22:40:00 12.3 2.3 19.5 8.4 12.2 2.3 19.1 8.4 11.8 2.5 19.1 7.2 329 14 344 165 -10.8 0 -10.6 -11 03/05/2007 22:50:00 11.3 1.5 14.9 7.6 11.2 1.5 14.9 7.2 11.2 1.6 16.1 6.8 325 11 317 165 -10.9 0 -10.8 -11 03/05/2007 23:00:00 11.4 2 18.7 6.1 11.2 2 18.7 5.7 11.2 2 17.6 6.5 327 13 347 165 -10.8 0 -10.6 -11.2 03/05/2007 23:10:00 11 1.7 15.6 6.8 10.7 1.7 15.6 6.5 10.5 1.6 15.3 7.2 326 17 3 165 -10.8 0 -10.6 -11 03/05/2007 23:20:00 10.7 1.7 15.3 6.8 10.6 1.7 15.3 5.3 10.6 1.6 14.5 6.8 331 12 338 165 -10.7 0 -10.6 -11 03/05/2007 23:30:00 12.4 2.3 19.1 7.6 11.9 2.3 19.1 7.2 12.3 2.7 20.2 3.8 332 17 324 165 -10.6 0 -10.6 -10.8 03/05/2007 23:40:00 13.7 2.8 20.2 8 13.3 2.9 19.9 7.6 13.7 2.9 19.9 6.8 334 14 350 165 -10.5 0 -10.4 -10.8 03/05/2007 23:50:00 11.8 2.3 16.8 7.2 11.2 2.2 16.4 6.1 11.7 2.4 17.2 6.8 333 17 308 165 -10.5 0 -10.4 -10.8 03/06/2007 00:00:00 13 2.9 19.5 6.5 12.6 2.8 19.9 6.1 12.6 3.1 19.5 6.5 333 15 343 165 -10.5 0 -10.4 -10.8 03/06/2007 00:10:00 12 1.8 18.7 8 11.1 2.2 17.9 5.7 11.7 1.9 17.6 6.8 335 17 2 165 -10.5 0 -10.4 -10.8 03/06/2007 00:20:00 10.7 1.3 16.1 7.6 10.4 1.5 16.1 6.5 10.5 1.2 16.1 7.6 327 15 318 165 -10.6 0 -10.6 -11 03/06/2007 00:30:00 12.8 2.6 19.9 7.6 12.6 2.8 19.9 7.2 12.7 2.8 19.1 6.1 332 12 337 165 -10.5 0 -10.4 -11 03/06/2007 00:40:00 11.6 1.8 17.2 6.8 11 2 16.1 6.8 11.3 1.9 16.8 6.1 339 13 345 165 -10.5 0 -10.4 -10.6 03/06/2007 00:50:00 13.8 2.3 20.2 8 13 2.3 19.1 8 13.6 2.6 20.2 7.6 334 17 341 165 -10.5 0 -10.4 -11 03/06/2007 01:00:00 12.8 2.6 20.6 7.2 12.5 2.7 20.6 7.6 12.8 2.8 20.2 5.7 334 14 333 165 -10.5 0 -10.4 -10.8 03/06/2007 01:10:00 10.8 1.5 16.1 8 10.7 1.5 16.4 7.6 10 1.7 15.6 6.1 318 17 345 165 -10.6 0 -10.6 -11 03/06/2007 01:20:00 13.5 2.4 19.1 9.1 13.3 2.5 19.1 8.8 13.1 2.6 19.5 8.4 325 15 330 165 -10.5 0 -10.4 -11 03/06/2007 01:30:00 14.3 2.4 21 7.6 13.7 2.6 20.2 7.2 14.4 2.5 21.4 8 332 14 332 165 -10.5 0 -10.6 -11 03/06/2007 01:40:00 12.9 2.1 18.7 8 12.5 2.2 19.5 7.6 12.9 2.2 17.9 7.6 334 13 349 165 -10.6 0.1 -10.6 -10.8 03/06/2007 01:50:00 11.8 1.9 16.4 7.6 11.1 1.9 16.1 6.1 11.6 1.9 17.9 6.8 332 17 355 165 -10.8 0 -10.6 -11 03/06/2007 02:00:00 12.4 2 17.2 6.5 12.3 2 17.6 6.8 11.7 2.3 18.7 4.6 318 16 324 165 -10.9 0 -10.8 -11 03/06/2007 02:10:00 14.4 1.8 20.6 9.5 14 2 21 8.8 14.3 2.2 20.2 8.8 332 15 341 165 -11 0 -11 -11.4 03/06/2007 02:20:00 12.3 1.9 17.9 8.8 12.2 1.9 17.6 8.8 12 2.3 18.3 7.2 319 15 327 165 -11.1 0 -11 -11.4 03/06/2007 02:30:00 10.8 1.5 15.6 6.1 10.6 1.7 15.6 6.5 10.4 1.5 15.3 6.8 330 14 333 165 -11.1 0 -11 -11.4 03/06/2007 02:40:00 10.3 1.5 14.5 6.5 10 1.6 14.9 6.5 10 1.5 14.9 6.5 326 17 4 165 -11.1 0 -11 -11.4 03/06/2007 02:50:00 11.1 2 17.2 6.5 10.4 2 16.4 6.5 10.5 2.5 17.9 5.3 325 22 327 165 -11.1 0 -11 -11.4 03/06/2007 03:00:00 11.6 2 17.9 7.2 11.3 2 19.1 6.8 11.2 2.2 16.1 5.7 329 15 324 165 -11.2 0 -11 -11.4 03/06/2007 03:10:00 13.9 2.4 18.3 6.1 13.6 2.6 17.9 5.3 13.8 2.6 18.3 5.3 335 13 346 165 -11.2 0 -11 -11.4 03/06/2007 03:20:00 14.5 2.1 21.4 9.1 14.1 2.4 21 7.6 14.1 2.3 21 8.8 337 11 319 165 -11.3 0 -11 -11.4 03/06/2007 03:30:00 12.8 1.7 18.7 7.6 12.4 2 17.9 6.5 12.5 2.1 17.2 7.6 332 15 344 165 -11.3 0 -11 -11.4 03/06/2007 03:40:00 10.1 1.7 16.1 6.5 9.9 1.7 16.4 6.5 9.7 1.9 15.6 5.7 321 15 334 165 -11.3 0 -11.2 -11.4 03/06/2007 03:50:00 12.5 2.3 17.9 6.8 12.1 2.5 18.7 6.5 12.4 2.4 17.9 7.2 335 12 332 165 -11.4 0 -11.2 -11.6 03/06/2007 04:00:00 14.7 2.7 21 6.5 13.9 2.7 19.5 6.5 14.7 3.1 21 6.1 338 12 357 165 -11.3 0 -11.2 -11.6 03/06/2007 04:10:00 11 1.3 14.1 7.2 10.8 1.5 14.1 6.1 10.9 1.5 14.9 7.6 333 13 326 165 -11.4 0 -11.4 -11.6 03/06/2007 04:20:00 8 1.7 12.6 4.2 7.6 1.5 13.7 4.2 7.5 1.6 13.7 4.2 330 15 338 165 -11.5 0 -11.4 -11.8 03/06/2007 04:30:00 7.3 1.2 11.1 4.6 7.1 1.4 11.1 3.8 6.8 1.2 10.7 3.8 325 18 297 165 -11.6 0 -11.4 -11.8 03/06/2007 04:40:00 7.3 1.5 11.1 3.4 7.1 1.6 11.1 3.8 6.8 1.7 11.1 3 325 14 328 165 -11.4 0.1 -11.2 -11.6 03/06/2007 04:50:00 7.5 1.5 11.5 3.8 7.1 1.8 11.1 3 6.7 1.5 10.7 3.8 330 19 332 165 -11.3 0 -11 -11.4 03/06/2007 05:00:00 7.5 1.5 11.5 3.8 7.4 1.6 11.5 3.4 7.2 1.7 12.2 2.3 331 11 332 165 -11.3 0 -11.2 -11.6 03/06/2007 05:10:00 8.8 1.9 14.1 4.6 8.7 1.9 13.7 4.6 8 2.1 13 3.8 320 13 305 165 -11.2 0 -11 -11.4 03/06/2007 05:20:00 10.2 1.4 15.3 4.6 10.1 1.4 14.9 4.2 8.7 1.5 14.9 4.9 305 13 295 165 -11.1 0 -11 -11.4 03/06/2007 05:30:00 10.6 2 16.1 6.1 10.4 1.9 15.6 6.1 10.4 2.2 16.4 4.2 327 15 348 165 -11.1 0 -11 -11.4 03/06/2007 05:40:00 12 2.3 17.6 5.3 11.6 2.3 18.3 4.9 11.8 2.4 18.7 5.7 333 12 331 165 -11.2 0 -11 -11.4 03/06/2007 05:50:00 12.6 2.2 21.8 8 12.3 2.4 21.8 6.1 12.3 2.2 22.1 7.2 330 15 327 165 -11.2 0 -11 -11.4 03/06/2007 06:00:00 11.9 1.4 14.9 6.8 11.5 1.4 14.9 7.6 11.6 1.7 16.4 7.2 331 15 354 165 -11.3 0 -11 -11.4 03/06/2007 06:10:00 12 2.2 17.9 7.2 11.7 2.2 18.7 7.2 11.6 2.2 17.2 6.8 325 17 287 165 -11.3 0 -11.2 -11.4 03/06/2007 06:20:00 15.5 2.5 21.8 10.7 15.2 2.8 22.9 8.8 15 2.6 22.9 9.9 335 13 347 165 -11.4 0 -11.4 -11.4 03/06/2007 06:30:00 13.8 1.9 18.7 9.9 13.5 2 18.7 9.5 13.3 1.9 17.9 8.8 328 12 332 165 -11.4 0 -11.2 -11.6 03/06/2007 06:40:00 14 1.8 20.6 9.9 13.8 1.8 20.2 10.3 13.5 2 20.2 8.8 318 12 313 165 -11.4 0 -11.4 -11.6 03/06/2007 06:50:00 15 2.1 21 8 14.9 2.1 21.4 7.6 13.9 1.7 19.5 9.9 310 10 286 165 -11.5 0 -11.4 -11.8 03/06/2007 07:00:00 14.1 1.8 19.1 8.8 13.9 1.8 18.7 8.8 12.8 2 18.3 7.6 310 13 301 165 -11.5 0 -11.4 -11.8 03/06/2007 07:10:00 13 1.9 17.2 8 12.9 1.8 16.8 8 12.2 2.1 17.6 6.5 315 11 319 165 -11.7 0.1 -11.4 -11.8 03/06/2007 07:20:00 13 1.9 19.1 8 12.8 1.8 19.1 8.4 12.6 1.7 18.3 8.4 326 14 5 165 -11.6 0 -11.4 -11.8 03/06/2007 07:30:00 12.9 1.8 17.6 8.8 12.7 1.8 17.2 9.1 12.3 1.8 16.8 7.2 315 9 314 165 -11.6 0 -11.4 -11.8 03/06/2007 07:40:00 13.2 2.2 19.5 8.4 12.9 2.2 20.2 7.6 12.4 2.5 19.5 8 322 17 342 165 -11.6 0 -11.4 -11.8 03/06/2007 07:50:00 13.5 1.9 17.9 8.4 12.9 1.8 18.3 7.6 13.2 2.1 20.6 8.4 331 15 333 165 -11.6 0 -11.4 -11.8 03/06/2007 08:00:00 13.6 2.5 19.5 7.6 13.1 2.3 20.2 6.8 12.8 2.7 19.9 6.1 326 17 4 165 -11.6 0 -11.4 -11.8 03/06/2007 08:10:00 14.6 2.1 19.9 9.1 14.2 2.3 19.9 8.8 14.1 2.4 20.2 6.8 337 12 334 165 -11.5 0 -11.4 -11.8 03/06/2007 08:20:00 14.5 2.6 21.4 8.4 13.8 2.4 20.6 8.8 14 2.7 21 8 332 17 358 165 -11.3 0 -11.2 -11.8 03/06/2007 08:30:00 14 2.1 21.4 9.5 13.6 2.2 21.8 9.5 13.4 2.3 21.8 8.8 334 15 338 165 -11.3 0 -11.2 -11.4 03/06/2007 08:40:00 15 2 21 9.5 14.8 2.1 20.6 9.5 14.3 1.9 20.6 9.9 322 17 301 165 -11.3 0 -11 -11.4 03/06/2007 08:50:00 13.9 2 18.7 8.4 13.5 2.1 18.3 7.2 12.8 2 17.9 7.6 319 20 315 165 -11.4 0 -11.2 -11.6 03/06/2007 09:00:00 16.5 2 22.9 11.5 16.2 2.2 22.9 10.7 15.8 1.9 22.6 11.5 319 16 288 165 -11.4 0 -11.4 -11.8 03/06/2007 09:10:00 15.7 2.4 22.1 10.3 15.6 2.3 21.8 10.3 14.5 2.5 21 9.5 314 13 320 165 -11.3 0.1 -11.2 -11.8 03/06/2007 09:20:00 15.4 1.9 20.6 9.9 15.2 1.9 20.2 10.3 14.5 1.9 20.6 9.5 319 17 315 165 -11.3 0 -11 -11.6 03/06/2007 09:30:00 14.9 2.1 19.5 9.5 14.6 2.1 19.5 9.5 14.1 2.1 19.5 9.1 323 14 300 165 -10.9 0.2 -10.6 -11.4 03/06/2007 09:40:00 13.1 1.7 17.9 8.8 12.9 1.7 17.6 8.4 12.4 1.7 16.4 8.4 327 13 332 165 -10.8 0 -10.6 -11 03/06/2007 09:50:00 14.2 2.5 21.4 9.1 13.9 2.4 21.8 8.8 13.5 2.5 19.9 8 333 14 334 165 -10.2 0.1 -10 -10.8 03/06/2007 10:00:00 14.3 2.1 19.9 9.9 14.1 2.1 19.5 9.5 13.3 1.8 19.9 9.1 317 14 302 165 -10.1 0.2 -9.7 -10.8 03/06/2007 10:10:00 15.1 1.8 19.5 10.7 14.9 1.8 19.9 10.3 14.4 1.8 18.3 8.8 312 9 302 165 -10.8 0.1 -10.6 -11.2 03/06/2007 10:20:00 16 1.8 20.2 10.3 15.8 1.8 20.2 10.3 15.1 1.9 20.2 9.1 312 10 314 165 -10.8 0.1 -10.6 -11 03/06/2007 10:30:00 15.2 1.7 20.2 10.3 15 1.7 19.9 10.3 14.2 1.8 18.7 9.1 312 8 298 165 -10.9 0 -10.8 -11.2 03/06/2007 10:40:00 17.6 2.1 23.3 11.8 17.4 2.1 23.3 11.5 16.7 2 21.8 11.1 312 11 301 165 -11.2 0.1 -11 -11.4 03/06/2007 10:50:00 18.7 1.7 23.3 13.7 18.5 1.7 22.6 13.3 17.8 2 22.6 12.6 311 9 306 165 -11.1 0 -11 -11.4 03/06/2007 11:00:00 18.4 1.7 24 13 18.2 1.7 24 12.6 17.4 1.9 22.6 13 311 8 313 165 -11 0.1 -10.8 -11.2 03/06/2007 11:10:00 18 1.8 22.6 12.6 17.8 1.8 22.1 13 17.1 2.1 23.3 11.8 312 11 315 165 -11 0 -10.8 -11.2 03/06/2007 11:20:00 16.5 1.9 20.2 11.8 16.3 1.8 20.2 11.1 15.2 2.2 21 10.3 311 11 319 165 -10.8 0.1 -10.6 -11 03/06/2007 11:30:00 17.2 2.3 25.2 11.5 17 2.3 25.6 11.1 15.9 2.4 21.4 9.5 308 10 274 165 -10.8 0 -10.6 -11 03/06/2007 11:40:00 19.3 2.1 24.4 13.7 19.2 2.1 24 14.1 17.9 2.3 25.6 11.5 309 10 304 165 -10.8 0.1 -10.6 -11.2 03/06/2007 11:50:00 17.4 2.4 24.8 9.9 17.2 2.3 24.8 10.7 16 2.1 22.6 11.5 313 12 299 165 -10.2 0.1 -10 -10.6 03/06/2007 12:00:00 18 2.4 25.2 10.3 17.8 2.3 24.4 10.3 15.5 2.3 22.6 5.7 304 10 283 165 -10.5 0.2 -10 -10.8 03/06/2007 12:10:00 18.2 2 23.7 12.6 18 2 23.7 10.7 16.6 2.1 22.9 9.9 307 11 300 165 -10.7 0 -10.6 -11 03/06/2007 12:20:00 16.7 2.1 23.3 11.8 16.6 2 22.6 11.8 14.9 2.2 20.6 9.5 306 10 297 165 -10.6 0 -10.4 -11 03/06/2007 12:30:00 16.8 2.1 24 12.2 16.6 2.1 23.3 11.5 14.5 2.1 22.1 8.8 303 10 289 165 -10.6 0.1 -10.2 -10.8 03/06/2007 12:40:00 18.3 2.2 24.8 12.2 18.2 2.2 24.8 12.2 15.1 2.4 24 10.7 299 9 300 165 -10.8 0 -10.6 -11 03/06/2007 12:50:00 17.4 1.9 23.7 10.7 17.3 1.9 23.7 11.5 13.3 2.1 21 8 295 8 292 165 -10.8 0.1 -10.6 -11 03/06/2007 13:00:00 16.9 2.3 22.1 9.9 16.9 2.2 21.8 9.9 13.3 2.1 20.2 6.8 295 7 293 165 -10.6 0 -10.4 -11 03/06/2007 13:10:00 15.4 2.1 21 9.5 15.3 2.1 20.6 9.9 12.2 2 19.1 7.6 293 10 292 165 -10.4 0 -10.2 -10.8 03/06/2007 13:20:00 13 2.5 21 7.6 12.9 2.5 20.2 6.8 10.9 2.7 19.9 5.3 302 15 323 165 -10 0.1 -9.7 -10.4 03/06/2007 13:30:00 13.9 1.9 19.9 8.8 13.9 1.8 19.5 9.1 11.4 2 19.1 7.2 297 10 307 165 -10 0.1 -9.7 -10.2 03/06/2007 13:40:00 14.2 1.9 20.6 8.4 14.1 1.9 20.2 8 12 1.8 16.8 7.6 300 12 306 165 -9.9 0.2 -9.3 -10.4 03/06/2007 13:50:00 15 1.8 19.9 9.5 14.9 1.8 19.5 9.5 12.6 1.9 17.9 7.6 300 12 305 165 -9.9 0.1 -9.5 -10.2 03/06/2007 14:00:00 15.9 2.1 21.4 10.3 15.7 2 20.2 10.3 13.2 2.2 19.5 7.2 303 9 290 165 -9.9 0 -9.7 -10.2 03/06/2007 14:10:00 16.2 2 20.6 11.5 16 1.9 20.2 11.1 13.2 1.9 18.3 7.2 301 10 303 165 -9.9 0.2 -9.5 -10.2 03/06/2007 14:20:00 14.3 2.4 22.1 8.8 14.2 2.3 22.1 8.4 12.5 2.1 19.9 7.2 305 12 302 165 -9.6 0.2 -9.3 -10 03/06/2007 14:30:00 12.7 2.1 18.7 7.6 12.6 2.1 18.7 7.6 11.2 1.7 15.6 7.2 309 17 273 165 -9.2 0.1 -8.7 -9.7 03/06/2007 14:40:00 13.4 2.6 19.9 8 13.2 2.7 20.6 8 12.9 2.7 20.6 7.2 326 15 354 165 -8.9 0.1 -8.5 -9.1 03/06/2007 14:50:00 14.6 2.1 19.9 8.8 14.3 2.3 19.5 7.6 13.1 2.2 18.7 7.6 319 19 337 165 -8.9 0 -8.7 -9.1 03/06/2007 15:00:00 13.6 2.1 20.2 8.4 13.4 2.1 19.5 7.6 12 2.1 17.9 7.2 313 15 328 165 -9 0.1 -8.7 -9.3 03/06/2007 15:10:00 13.7 2 20.2 8 13.5 2 20.2 7.2 12.5 2 17.9 8 314 14 304 165 -8.9 0.1 -8.5 -9.1 03/06/2007 15:20:00 13.4 1.4 17.6 9.5 13 1.5 16.8 8.4 12.8 1.5 16.8 8.8 328 17 347 165 -8.8 0 -8.5 -8.9 03/06/2007 15:30:00 13 2.4 19.5 6.8 12.7 2.4 19.5 7.6 12.3 2.1 18.7 8 324 16 339 165 -8.8 0.1 -8.5 -9.1 03/06/2007 15:40:00 13 2.7 19.9 7.2 12.8 2.7 20.2 6.8 12.4 2.7 20.6 5.7 326 18 338 165 -8.9 0.1 -8.5 -9.3 03/06/2007 15:50:00 12.5 2.5 18.7 4.6 12.2 2.5 17.2 4.6 10.9 2.3 17.2 5.3 321 20 2 165 -8.6 0.1 -8.3 -8.9 03/06/2007 16:00:00 13.1 2.2 19.1 6.8 12.9 2.3 19.1 6.8 11.3 2.5 18.7 4.6 322 20 319 165 -8.4 0.2 -8.1 -8.9 03/06/2007 16:10:00 16.4 2.4 25.6 10.3 16.2 2.3 25.2 10.3 13.9 2.7 20.6 7.2 311 14 290 165 -9.2 0.1 -8.7 -9.3 03/06/2007 16:20:00 21.5 2 26.3 15.3 21.3 1.9 25.6 16.1 19.7 2.3 25.6 13 307 9 307 165 -10 0.4 -9.1 -10.6 03/06/2007 16:30:00 21.7 2 27.5 16.8 21.4 2 27.1 17.2 20 2.2 25.2 14.1 307 8 307 165 -10.3 0 -10.2 -10.8 03/06/2007 16:40:00 21.6 2.5 30.2 14.5 21.3 2.4 29.1 14.5 19.6 2.2 25.2 14.1 309 9 294 165 -10.2 0.1 -9.7 -10.6 03/06/2007 16:50:00 23.8 1.9 29.1 17.6 23.6 1.9 28.3 16.8 22.7 2.2 27.5 16.8 308 8 301 165 -10.4 0 -10.2 -10.6 03/06/2007 17:00:00 25.1 1.5 29.1 19.9 25 1.6 28.7 20.2 24.9 1.7 28.3 18.3 311 6 299 165 -10.7 0.1 -10.6 -11 03/06/2007 17:10:00 24.5 1.8 28.3 18.3 24.4 1.8 27.9 17.9 23.9 2.4 27.9 15.3 311 7 301 165 -10.8 0 -10.6 -11 03/06/2007 17:20:00 24.4 2 30.9 18.3 24.3 2.1 30.2 17.9 23.7 2 28.3 17.2 310 9 287 165 -10.8 0 -10.6 -11 03/06/2007 17:30:00 24.5 2.2 30.9 17.6 24.4 2.2 30.9 17.2 24.2 2.3 30.6 16.1 311 7 305 165 -10.7 0 -10.6 -11 03/06/2007 17:40:00 24.4 2.4 29.1 17.2 24.2 2.4 29.4 17.6 23.8 2.6 32.1 16.8 309 9 293 165 -10.9 0 -10.8 -11.2 03/06/2007 17:50:00 23.9 2.5 30.2 16.1 23.8 2.5 29.4 16.1 22.7 2.7 28.7 14.5 306 9 302 165 -11 0 -10.8 -11.4 03/06/2007 18:00:00 25 2.6 30.6 17.9 24.9 2.6 30.2 18.3 23.3 2.8 30.6 15.3 303 9 297 165 -11.2 0 -11 -11.4 03/06/2007 18:10:00 24.8 2.6 31.3 17.6 24.8 2.6 31.3 17.2 23.2 2.6 28.7 14.9 303 10 293 165 -11.3 0 -11.2 -11.6 03/06/2007 18:20:00 24.8 2.5 30.2 17.2 24.8 2.6 30.2 16.4 23.9 2.6 30.2 14.9 305 9 296 165 -11.4 0 -11.4 -11.6 03/06/2007 18:30:00 24.9 2.2 30.2 17.6 24.8 2.2 29.8 17.2 23.9 2.3 29.8 16.4 307 10 309 165 -11.4 0 -11.2 -11.6 03/06/2007 18:40:00 24.8 2 29.4 18.3 24.6 2.1 29.4 18.7 24.1 2 28.7 18.7 307 10 315 165 -11.5 0 -11.4 -11.6 03/06/2007 18:50:00 26.1 2.2 32.1 20.2 26.1 2.3 32.1 20.6 25.5 2.4 31.3 18.3 307 9 291 165 -11.4 0 -11.2 -11.8 03/06/2007 19:00:00 26.8 2 30.9 19.5 26.7 2.1 31.3 19.5 26.3 2.1 30.9 18.7 306 10 312 165 -11.4 0.1 -11 -11.8 03/06/2007 19:10:00 27.1 1.9 31.8 19.9 27 1.9 31.8 19.5 26.9 2.2 31.8 20.6 309 7 303 165 -11.3 0.1 -11 -11.4 03/06/2007 19:20:00 25.2 1.9 28.7 17.9 25.1 1.9 29.1 17.6 24.1 2.5 29.4 16.4 307 10 295 165 -11.7 0.2 -11.4 -11.8 03/06/2007 19:30:00 25.1 2.1 29.4 19.1 25 2.1 29.4 18.7 24 2.4 30.2 16.8 307 9 310 165 -11.8 0 -11.6 -11.8 03/06/2007 19:40:00 23.6 1.8 28.3 18.7 23.5 1.9 28.7 17.9 22.9 2.3 27.9 16.1 308 9 308 165 -11.8 0 -11.6 -11.8 03/06/2007 19:50:00 21.4 2.3 27.1 15.6 21.3 2.3 26.8 14.9 19.5 2.3 25.6 12.2 302 10 301 165 -11.9 0 -11.8 -12 03/06/2007 20:00:00 22.5 2.1 29.4 16.1 22.3 2.1 29.1 15.6 21.3 2.1 25.6 13.7 306 10 298 165 -11.6 0.1 -11.2 -12.2 03/06/2007 20:10:00 23 2.4 29.1 15.3 22.9 2.4 29.1 15.6 21.4 2.6 27.5 13.7 303 11 305 165 -11.7 0 -11.6 -11.8 03/06/2007 20:20:00 24.1 2.5 30.2 17.9 24 2.5 29.8 17.6 22.1 2.5 29.8 14.9 302 11 302 165 -11.6 0 -11.4 -11.8 03/06/2007 20:30:00 22.8 2.4 30.9 15.3 22.6 2.4 30.6 15.3 20.8 2.5 26.8 13.7 303 12 305 165 -11.6 0 -11.4 -11.8 03/06/2007 20:40:00 24.2 2.8 33.2 14.1 24.1 2.8 33.2 14.5 22.7 2.9 30.9 13.7 304 11 304 165 -11.6 0 -11.4 -11.8 03/06/2007 20:50:00 23.3 2.6 30.6 17.6 23.2 2.6 30.2 17.6 21.7 2.6 27.9 15.3 304 12 293 165 -11.8 0 -11.6 -12 03/06/2007 21:00:00 22 2.5 32.1 14.5 21.8 2.5 31.8 15.3 20.1 2.6 27.9 12.2 302 14 306 165 -11.7 0.1 -11.4 -11.8 03/06/2007 21:10:00 22.5 2 27.5 16.4 22.3 2 27.5 16.4 20.1 2.3 26.8 14.5 300 11 304 165 -11.9 0 -11.8 -12 03/06/2007 21:20:00 22.4 2.6 29.1 15.6 22.3 2.5 28.3 15.6 19.1 2.6 24.8 11.5 296 12 274 165 -12 0 -11.8 -12.2 03/06/2007 21:30:00 22.2 3.1 32.1 13 22.1 2.9 32.1 13 18.4 2.9 25.2 10.3 294 11 291 165 -11.9 0.2 -11.4 -12.4 03/06/2007 21:40:00 20.7 3.3 32.1 12.2 20.5 3.2 31.3 12.2 17.9 2.9 27.1 11.8 297 15 300 165 -11.7 0.1 -11.4 -11.8 03/06/2007 21:50:00 22.2 3.6 31.8 13.3 22.1 3.5 30.9 13.3 19.3 3.3 28.3 11.1 296 13 269 165 -11.8 0.2 -11.2 -12 03/06/2007 22:00:00 20.4 2.6 26.8 14.1 20.2 2.6 27.1 13.3 16.9 2.5 25.2 11.1 296 11 275 165 -11.8 0.2 -11.2 -12 03/06/2007 22:10:00 20.9 2.9 32.1 11.1 20.8 2.9 30.6 11.5 17.3 2.9 26.3 9.5 292 12 283 165 -12 0 -11.8 -12.2 03/06/2007 22:20:00 22.6 2 29.1 17.9 22.5 2 28.7 17.6 19.4 2.4 24.4 12.6 297 9 297 165 -12 0 -11.6 -12.4 03/06/2007 22:30:00 22.2 2.3 28.7 16.1 22 2.3 27.1 16.1 19.7 2.7 26.8 13.3 301 10 300 165 -12.1 0 -11.8 -12.4 03/06/2007 22:40:00 22.8 2.2 29.8 16.4 22.6 2.2 29.8 16.4 18.8 2.3 24.8 13 296 11 290 165 -12 0 -11.8 -12.4 03/06/2007 22:50:00 22.5 2.7 30.2 15.3 22.3 2.6 30.2 15.6 18.1 3.1 27.9 11.8 293 10 293 165 -12 0.1 -11.8 -12.4 03/06/2007 23:00:00 22 3.1 28.7 13.7 21.8 2.9 28.3 14.1 18.4 2.7 24.4 11.1 294 13 290 165 -12 0 -11.8 -12.2 03/06/2007 23:10:00 21.6 2.8 27.9 13.7 21.4 2.8 27.1 13.7 19.1 2.6 24.8 11.5 299 12 300 165 -11.9 0.1 -11.6 -12.2 03/06/2007 23:20:00 22.8 2.4 27.9 14.9 22.7 2.4 27.9 14.1 19.4 2.4 26 12.2 297 11 302 165 -11.9 0 -11.8 -12 03/06/2007 23:30:00 22.2 2.5 29.1 14.9 22.1 2.5 28.7 14.9 19.1 2.6 26.3 12.2 299 10 287 165 -11.6 0.2 -11.2 -12.2 03/06/2007 23:40:00 21.1 2.4 27.1 13.7 20.9 2.4 26.8 13.7 17.7 2.7 24 10.7 295 13 288 165 -11.4 0 -11.2 -11.6 03/06/2007 23:50:00 22.3 2.7 29.1 15.3 22.3 2.7 28.7 14.9 18.9 2.6 27.1 11.1 294 11 297 165 -11.4 0 -11.4 -11.8 03/07/2007 00:00:00 22.9 2.5 30.6 16.8 22.8 2.5 29.8 16.8 19.4 2.6 26.8 12.2 294 11 275 165 -11.4 0 -11.2 -11.6 03/07/2007 00:10:00 23.5 2.1 30.6 18.3 23.4 2.1 30.6 18.7 20 2.2 26.3 14.1 294 11 265 165 -11.4 0 -11.2 -11.8 03/07/2007 00:20:00 22.6 2.1 27.5 16.8 22.5 2 27.1 16.8 18.6 2.3 26.8 11.5 295 10 297 165 -11.6 0 -11.4 -11.8 03/07/2007 00:30:00 23.2 2.3 28.3 15.6 23.2 2.3 27.9 15.6 19.7 2.7 26.3 11.1 294 11 301 165 -11.6 0 -11.4 -11.8 03/07/2007 00:40:00 22.4 2 27.9 16.4 22.3 2 27.5 16.8 19 2.5 25.2 12.6 294 13 282 165 -11.6 0 -11.6 -12 03/07/2007 00:50:00 21 2.4 27.1 15.3 20.9 2.4 27.1 15.3 17.6 2.7 23.7 11.1 293 15 289 165 -11.4 0 -11.2 -11.8 03/07/2007 01:00:00 19.7 2.3 25.2 13 19.5 2.3 24.8 13 16 2.6 22.1 9.5 295 11 293 165 -11.5 0 -11.4 -11.8 03/07/2007 01:10:00 18.5 1.9 24 13.7 18.4 1.9 23.7 13.7 14.8 2.1 23.3 9.1 292 14 302 165 -11.5 0 -11.2 -11.8 03/07/2007 01:20:00 18.5 2.5 25.2 12.2 18.4 2.5 24.8 11.8 14.4 2.4 22.9 9.1 290 12 309 165 -11.8 0.1 -11.6 -12 03/07/2007 01:30:00 17.6 2 22.9 12.2 17.5 2 22.1 11.5 13.6 2.1 22.1 9.5 289 14 283 165 -11.9 0.1 -11.6 -12.2 03/07/2007 01:40:00 17.3 2.3 23.7 11.1 17.3 2.2 23.7 10.7 13.5 2.4 22.6 7.6 288 12 284 165 -11.7 0.2 -11.2 -12 03/07/2007 01:50:00 17.2 2.7 23.7 11.1 17.2 2.7 23.7 11.1 13.6 2.6 23.3 8.4 291 12 302 165 -11.8 0 -11.6 -12 03/07/2007 02:00:00 18 2.2 23.3 12.2 17.9 2.2 22.9 12.2 13.7 2.1 22.1 8.8 287 11 289 165 -11.7 0 -11.4 -12 03/07/2007 02:10:00 19.1 2.4 25.2 13 19 2.4 24.8 13 14.6 2.5 22.9 9.5 293 12 288 165 -11.8 0 -11.6 -12 03/07/2007 02:20:00 18.9 2.2 24.4 13 18.8 2.2 24 13 14.9 2.4 21.4 9.5 294 14 296 165 -11.6 0 -11.4 -12.2 03/07/2007 02:30:00 18.3 1.8 22.9 13.7 18.3 1.8 22.6 13.3 14.3 1.7 19.9 10.7 295 12 293 165 -11.6 0 -11.4 -11.8 03/07/2007 02:40:00 18.1 2.8 22.6 9.9 18 2.8 22.6 10.3 14 2.1 19.5 8.4 291 13 261 165 -11.6 0 -11.4 -12 03/07/2007 02:50:00 18.9 2.3 24.8 11.1 18.8 2.3 24.4 11.8 14.3 2.4 22.9 8.8 291 11 278 165 -11.5 0 -11.4 -11.8 03/07/2007 03:00:00 19.1 2.4 25.6 10.3 19 2.4 25.2 11.1 14.8 2.5 22.6 9.1 292 13 273 165 -11.6 0 -11.4 -11.8 03/07/2007 03:10:00 19.3 2.3 23.3 9.9 19.2 2.4 23.7 9.5 14.8 2.2 22.6 9.5 293 11 289 165 -11.6 0 -11.6 -11.8 03/07/2007 03:20:00 18.2 2 22.9 12.2 18.1 2.1 22.9 11.8 14.3 2.5 22.6 8.4 290 12 296 165 -11.6 0 -11.4 -11.8 03/07/2007 03:30:00 18.4 2.1 24 11.5 18.3 2.1 23.7 11.8 14.4 2.5 22.1 8.8 290 11 302 165 -11.6 0 -11.4 -11.8 03/07/2007 03:40:00 17.3 2.7 23.7 10.7 17.2 2.6 23.3 10.3 13.8 2.5 21.8 8 290 12 293 165 -11.4 0 -11.4 -11.6 03/07/2007 03:50:00 17.3 2.7 22.9 8 17.2 2.7 22.6 8 13.4 2.2 19.9 7.6 291 13 273 165 -11.5 0 -11.2 -11.6 03/07/2007 04:00:00 17.5 2.1 22.1 12.2 17.3 2.1 21.4 11.8 13.5 2.2 19.9 8 289 13 292 165 -11.6 0 -11.4 -11.8 03/07/2007 04:10:00 17.2 2 22.1 10.3 17.1 2 21.8 9.9 13.3 2.1 18.7 7.6 292 12 280 165 -11.6 0 -11.6 -11.8 03/07/2007 04:20:00 17.1 1.6 21.4 13 16.9 1.6 21 13 13.6 2 18.7 8.8 296 11 277 165 -11.5 0 -11.4 -11.8 03/07/2007 04:30:00 15.1 1.7 20.2 9.5 15 1.7 19.5 9.9 11.9 1.8 17.2 6.8 296 12 297 165 -11.5 0 -11.4 -11.8 03/07/2007 04:40:00 15.4 1.7 21 11.1 15.2 1.7 20.2 11.1 12.1 1.6 16.4 8.8 296 12 295 165 -11.5 0 -11.4 -11.8 03/07/2007 04:50:00 15 1.7 19.1 10.7 14.8 1.7 18.3 11.5 12.2 1.8 17.2 8.4 299 13 295 165 -11.4 0 -11.4 -11.8 03/07/2007 05:00:00 14.3 1.9 20.2 9.5 14.2 1.9 19.1 9.1 12.7 2.1 18.3 7.2 304 12 280 165 -11.4 0 -11.2 -11.8 03/07/2007 05:10:00 14.3 1.8 17.9 9.5 14.2 1.8 17.9 9.5 13.1 2.1 17.6 8.4 305 11 307 165 -11.4 0 -11.4 -11.8 03/07/2007 05:20:00 14.1 1.5 18.3 9.9 13.9 1.5 17.9 9.5 13 1.8 17.6 8.4 306 11 302 165 -11.4 0 -11.4 -11.6 03/07/2007 05:30:00 13.4 1.6 17.6 9.1 13.3 1.7 17.6 9.1 12.3 1.9 17.9 8 306 12 295 165 -11.5 0 -11.4 -11.8 03/07/2007 05:40:00 13.8 1.6 19.1 9.9 13.7 1.6 18.7 10.3 13 1.7 17.2 8 307 12 272 165 -11.6 0 -11.4 -11.8 03/07/2007 05:50:00 15.1 1.7 19.5 10.3 15 1.7 19.5 9.9 14.3 1.9 18.3 9.1 306 11 303 165 -11.5 0 -11.4 -11.8 03/07/2007 06:00:00 15 1.6 18.3 10.3 14.8 1.7 18.3 10.3 14.3 2.1 19.1 9.9 306 13 316 165 -11.6 0 -11.4 -11.8 03/07/2007 06:10:00 14.3 1.7 18.3 9.1 14.2 1.6 17.9 9.1 13.4 1.9 17.6 7.6 307 11 304 165 -11.6 0 -11.4 -12 03/07/2007 06:20:00 14.5 1.5 18.3 10.3 14.4 1.5 18.3 9.9 14 1.9 17.9 9.1 309 12 310 165 -11.6 0 -11.4 -11.8 03/07/2007 06:30:00 13.8 1.7 18.3 9.1 13.7 1.7 17.9 9.1 13.2 1.7 17.6 7.2 310 13 245 165 -11.6 0 -11.4 -11.8 03/07/2007 06:40:00 15.9 1.3 18.7 10.7 15.8 1.3 18.3 10.7 14.7 1.8 19.1 11.1 303 12 310 165 -11.8 0 -11.6 -11.8 03/07/2007 06:50:00 15.7 1.1 18.3 13 15.7 1.2 18.3 12.6 13.4 1.7 17.2 9.1 301 11 287 165 -11.9 0 -11.8 -12 03/07/2007 07:00:00 15.3 1 17.9 11.8 15.1 1.1 17.9 11.5 13.7 1.7 17.2 8.8 305 10 309 165 -11.9 0 -11.8 -12.2 03/07/2007 07:10:00 14.5 1.5 17.2 10.3 14.3 1.5 17.2 10.7 14.1 1.3 17.6 10.3 311 9 305 165 -11.9 0 -11.8 -12.2 03/07/2007 07:20:00 13.9 1.2 16.4 11.1 13.8 1.1 16.4 10.7 13.9 1.2 16.8 10.7 311 10 310 165 -12 0 -11.8 -12.2 03/07/2007 07:30:00 14.2 1 16.4 11.1 14.1 1 16.8 10.7 13.8 1.1 16.4 10.7 309 9 313 165 -12.1 0 -12 -12.4 03/07/2007 07:40:00 13.2 0.9 15.3 11.1 13.1 1 15.3 10.7 13 1.1 15.6 9.5 312 8 313 165 -12.1 0 -12 -12.4 03/07/2007 07:50:00 13.3 1 15.3 10.3 13.3 1 15.3 10.3 13 1.1 15.6 9.9 310 10 307 165 -12.2 0 -12 -12.4 03/07/2007 08:00:00 14.1 0.7 16.4 11.8 14.1 0.7 16.4 12.2 13.8 1 16.8 9.9 307 9 307 165 -12.2 0 -12 -12.4 03/07/2007 08:10:00 14 1 16.4 11.1 14 1 16.1 10.7 13.6 1.2 16.1 10.3 308 9 310 165 -12.1 0 -12 -12.4 03/07/2007 08:20:00 14.4 0.9 16.8 12.2 14.4 1 16.8 11.8 14.2 1.1 16.8 10.7 308 8 309 165 -12.1 0 -12 -12.4 03/07/2007 08:30:00 14.3 1.2 16.4 11.5 14.3 1.2 16.4 11.1 14 1.3 16.8 10.3 306 11 298 165 -12.2 0 -12.2 -12.4 03/07/2007 08:40:00 14.2 1 16.4 11.1 14.1 1 16.1 11.1 14.1 1 16.8 11.1 309 9 312 165 -12.1 0 -12 -12.2 03/07/2007 08:50:00 14.2 1.1 16.8 11.1 14.2 1.2 16.4 10.7 13.9 1.2 16.8 10.3 304 11 314 165 -12.1 0 -12 -12.4 03/07/2007 09:00:00 13.4 1.3 17.2 9.9 13.3 1.3 16.8 10.3 11.3 1.9 16.1 7.6 292 14 304 165 -12.1 0 -12 -12.4 03/07/2007 09:10:00 13 1 15.3 10.3 13 1 15.3 10.3 10.1 1.3 14.9 7.6 290 12 293 165 -12 0 -11.8 -12.4 03/07/2007 09:20:00 13.4 0.9 16.1 10.7 13.5 0.9 15.6 10.7 10.6 1.4 15.3 7.6 287 14 294 165 -11.8 0.1 -11.4 -12.2 03/07/2007 09:30:00 13.3 1 15.6 10.7 13.3 1 15.6 10.7 10.2 1.2 14.1 7.6 290 12 290 165 -11.5 0 -11.4 -11.8 03/07/2007 09:40:00 13.6 1.2 16.1 8.4 13.6 1.2 16.1 9.1 10.8 1.5 16.4 7.2 291 13 284 165 -11.4 0 -11.4 -11.6 03/07/2007 09:50:00 14.2 1.1 17.2 11.1 14.1 1.1 16.8 10.7 11.9 1.3 15.6 8.4 295 13 307 165 -11.6 0.1 -11.4 -11.8 03/07/2007 10:00:00 14.1 1 16.4 11.1 14.1 1 16.4 11.1 10.7 1.2 14.5 8 294 12 305 165 -11.8 0 -11.6 -11.8 03/07/2007 10:10:00 13.9 1 16.1 10.7 13.9 1.1 16.1 10.7 10.6 1.2 13.7 8 290 14 242 165 -11.6 0 -11.4 -11.8 03/07/2007 10:20:00 14.6 1.5 17.6 11.1 14.5 1.6 17.6 10.7 11.1 1.3 14.9 7.6 292 13 269 165 -11.5 0.1 -11.2 -11.8 03/07/2007 10:30:00 15 1.3 18.3 11.8 14.9 1.3 17.9 11.5 12.4 1.7 17.2 9.1 295 13 299 165 -11.3 0 -11.2 -11.4 03/07/2007 10:40:00 14.9 1.5 18.7 11.1 14.9 1.5 18.3 11.1 12.8 1.6 16.8 9.5 296 15 305 165 -11.4 0 -11.4 -11.6 03/07/2007 10:50:00 15.1 1.4 18.3 11.1 14.9 1.5 18.7 11.5 13 1.8 17.2 8.4 297 14 274 165 -11.4 0 -11.4 -11.8 03/07/2007 11:00:00 14.7 1.5 17.6 11.1 14.6 1.5 17.6 11.1 13.1 1.6 16.8 9.5 298 15 301 165 -11.4 0 -11.4 -11.8 03/07/2007 11:10:00 15.8 1.4 19.9 12.2 15.7 1.4 19.9 12.6 14.5 1.8 18.7 10.3 298 16 292 165 -11.3 0 -11.2 -11.6 03/07/2007 11:20:00 16.2 1.3 19.5 13.3 16.1 1.3 19.5 13.3 15.4 1.7 18.7 9.9 304 13 309 165 -11.3 0 -11.2 -11.6 03/07/2007 11:30:00 16.7 1.2 19.1 13.7 16.5 1.2 19.1 13.7 16.3 1.3 19.1 12.6 307 11 301 165 -11.3 0 -11.2 -11.4 03/07/2007 11:40:00 17.2 1.4 19.9 11.8 17.1 1.4 19.5 11.8 16.2 2.2 19.9 8.4 306 11 315 165 -11.5 0 -11.4 -11.8 03/07/2007 11:50:00 16.5 1.1 18.7 13 16.4 1.1 18.7 13 14.7 1.7 18.3 9.9 303 12 302 165 -11.4 0 -11.4 -11.8 03/07/2007 12:00:00 15.2 1.2 17.2 11.5 15.1 1.2 17.2 11.5 13.7 1.4 16.8 9.1 303 12 309 165 -11.3 0 -11 -11.6 03/07/2007 12:10:00 14.4 1.3 16.8 8.4 14.3 1.3 16.8 8 12.7 1.5 16.4 9.1 300 14 297 165 -11.3 0 -11 -11.6 03/07/2007 12:20:00 14.9 1 17.2 11.8 14.8 1 17.2 11.8 12.6 1.6 15.6 8.8 299 13 300 165 -11.1 0 -11 -11.4 03/07/2007 12:30:00 14.3 1.4 17.9 10.7 14.3 1.4 17.9 10.7 12.5 1.5 16.8 9.1 300 13 297 165 -11 0 -10.8 -11.4 03/07/2007 12:40:00 14.1 1.9 17.9 9.5 14.1 1.9 17.9 8.8 12.3 1.4 15.6 5.7 298 14 295 165 -10.9 0 -10.8 -11.2 03/07/2007 12:50:00 13.5 1.5 16.8 9.5 13.5 1.5 16.8 9.9 11.3 1.7 16.4 7.2 294 15 296 165 -10.8 0 -10.6 -11 03/07/2007 13:00:00 15.1 1.4 18.3 11.1 15 1.5 17.9 11.1 12.2 1.7 17.2 8.4 292 16 280 165 -11 0 -11 -11.4 03/07/2007 13:10:00 15 1.3 18.3 11.5 14.9 1.3 17.9 11.5 11.9 1.6 16.4 8.8 294 12 287 165 -11.1 0 -11 -11.4 03/07/2007 13:20:00 16.6 1.5 19.9 13 16.6 1.5 19.9 13 12.6 1.5 17.6 9.1 290 15 295 165 -11.2 0 -11 -11.4 03/07/2007 13:30:00 15.6 1.3 19.1 11.1 15.5 1.3 19.1 11.5 11.9 1.5 16.1 8.8 290 15 294 165 -11.2 0 -11 -11.4 03/07/2007 13:40:00 14.6 1.3 17.9 10.7 14.6 1.3 17.9 10.7 11.4 1.5 15.3 8 287 16 298 165 -11.2 0 -11 -11.4 03/07/2007 13:50:00 14.1 1.7 17.6 9.1 14.1 1.7 17.6 9.1 11.1 1.3 15.6 7.6 287 14 295 165 -10.9 0.1 -10.8 -11.4 03/07/2007 14:00:00 15.7 1.7 19.1 10.3 15.6 1.7 19.5 10.3 12.1 1.8 17.6 8 287 12 301 165 -10.9 0 -10.8 -11 03/07/2007 14:10:00 14 1.5 17.2 9.5 13.9 1.5 17.2 9.5 11.3 1.6 14.9 7.2 293 15 302 165 -10.8 0 -10.6 -11.2 03/07/2007 14:20:00 14.2 1.7 19.5 10.3 14.2 1.7 19.5 10.3 11.8 1.7 17.2 7.6 292 17 302 165 -10.6 0 -10.6 -11 03/07/2007 14:30:00 15 1.8 19.9 10.3 14.9 1.8 18.3 9.9 11.8 1.7 16.8 7.2 292 14 297 165 -10.6 0 -10.4 -10.8 03/07/2007 14:40:00 15.7 1.8 19.5 11.1 15.6 1.8 19.5 11.1 12 1.6 16.1 8 293 15 306 165 -10.6 0 -10.4 -10.8 03/07/2007 14:50:00 16.5 1.2 20.2 13 16.4 1.2 20.2 13 13.2 1.9 18.3 9.1 296 13 283 165 -10.7 0 -10.6 -11 03/07/2007 15:00:00 17 1.7 20.2 12.6 17 1.7 20.2 12.6 14.3 2.5 20.2 8.8 296 13 284 165 -10.8 0 -10.6 -11 03/07/2007 15:10:00 17.8 1.3 21 13.3 17.8 1.3 20.6 13.7 13.6 2 18.3 9.5 292 13 302 165 -10.9 0 -10.8 -11.2 03/07/2007 15:20:00 18.1 1.3 20.6 13.3 18.1 1.3 21 13.3 13.9 1.7 18.7 9.9 290 17 285 165 -11 0 -10.8 -11.4 03/07/2007 15:30:00 17.8 2 22.6 13.3 17.7 2 22.6 13.3 16.2 2.6 22.1 8.8 296 16 310 165 -10.9 0 -10.8 -11.2 03/07/2007 15:40:00 19.7 1.5 22.9 15.3 19.6 1.5 22.9 15.6 17.9 2.2 22.1 13 296 16 301 165 -11.2 0.1 -11 -11.4 03/07/2007 15:50:00 19.1 1.3 22.1 14.9 19 1.3 22.1 14.9 16.9 2.2 21.4 11.8 294 17 274 165 -11.3 0 -11.2 -11.4 03/07/2007 16:00:00 20.3 1.6 23.7 14.9 20.3 1.6 23.7 14.9 17.2 2 21.8 11.8 291 17 302 165 -11.4 0 -11.2 -11.6 03/07/2007 16:10:00 20.5 1.9 24.4 15.6 20.5 1.9 24.4 16.1 18 2.2 22.9 12.6 296 14 302 165 -11.5 0 -11.4 -11.8 03/07/2007 16:20:00 20.3 1.7 23.7 16.1 20.3 1.7 23.7 16.1 18.7 2 23.7 13.3 295 15 299 165 -11.5 0 -11.4 -11.8 03/07/2007 16:30:00 20.6 1.6 24.4 15.6 20.5 1.7 24.8 15.6 18.1 2.2 22.6 12.6 293 17 285 165 -11.7 0 -11.6 -12 03/07/2007 16:40:00 17.5 1.7 23.3 13.3 17.4 1.7 22.9 13 15.6 2.4 21.8 10.3 294 18 244 165 -11.7 0 -11.6 -11.8 03/07/2007 16:50:00 19.3 1.5 22.6 14.9 19.2 1.5 22.6 14.9 16 2.4 21.4 11.1 292 15 304 165 -11.8 0 -11.6 -12 03/07/2007 17:00:00 19.8 1.5 22.6 15.6 19.8 1.5 22.9 15.3 15.3 1.9 21 11.5 289 15 293 165 -11.9 0 -11.8 -11.8 03/07/2007 17:10:00 18.5 1.4 22.1 15.3 18.4 1.5 22.1 15.3 15.3 1.7 20.6 11.1 296 14 300 165 -11.9 0 -11.8 -12 03/07/2007 17:20:00 17 1.3 20.6 13.7 16.8 1.4 20.6 13.7 15.8 1.5 20.2 11.8 306 11 312 165 -11.9 0 -11.8 -12.2 03/07/2007 17:30:00 15.4 1.5 18.7 10.7 15.2 1.5 18.3 10.7 14.6 1.6 17.9 9.5 310 9 312 165 -11.9 0 -11.8 -12.2 03/07/2007 17:40:00 12.2 1.4 15.3 8.4 12 1.3 14.5 7.6 11.5 1.6 14.9 6.8 313 10 309 165 -11.8 0 -11.6 -12 03/07/2007 17:50:00 12.4 1.2 15.3 8 12.2 1.2 14.9 8 11.8 1.2 14.5 8.4 313 11 306 165 -11.9 0 -11.8 -12.2 03/07/2007 18:00:00 12.4 1.1 14.9 9.1 12.2 1.1 14.5 8.4 11.8 1.2 14.9 7.6 312 12 310 165 -12.2 0.1 -12 -12.4 03/07/2007 18:10:00 13 1.2 15.6 9.9 12.9 1.2 15.3 10.3 12.2 1.3 15.3 8.8 308 11 282 165 -12.5 0 -12.4 -12.6 03/07/2007 18:20:00 12.4 1.4 14.9 8 12.2 1.5 15.3 8.8 11.6 1.3 14.5 8.8 307 13 295 165 -12.6 0 -12.6 -12.8 03/07/2007 18:30:00 13.8 1.2 17.6 9.5 13.7 1.2 16.8 9.9 13.4 1.2 16.4 9.9 310 10 314 165 -12.7 0 -12.6 -13 03/07/2007 18:40:00 13.4 1.2 16.1 10.3 13.2 1.1 15.6 10.7 12.9 1.4 16.1 8.8 313 10 315 165 -12.9 0 -12.6 -13.2 03/07/2007 18:50:00 12.1 1.3 15.6 8.8 11.9 1.3 15.3 8.4 11.5 1.5 14.9 7.6 318 11 313 165 -13 0 -12.8 -13.2 03/07/2007 19:00:00 12.6 1.2 15.3 6.8 12.4 1.3 14.9 7.2 12.3 1.4 15.6 8 316 10 302 165 -13.1 0 -13 -13.4 03/07/2007 19:10:00 14.2 1.1 16.4 11.1 14.1 1.1 16.4 10.7 14 1.3 16.4 10.3 314 7 313 165 -13.3 0 -13.2 -13.6 03/07/2007 19:20:00 13.4 1 15.6 10.7 13.2 1 15.3 10.3 13.2 1.1 15.6 9.9 317 8 315 165 -13.3 0 -13.2 -13.6 03/07/2007 19:30:00 12.7 1.3 16.1 9.1 12.5 1.3 15.6 8.8 12.2 1.3 15.3 8.4 312 10 300 165 -13.4 0 -13.2 -13.6 03/07/2007 19:40:00 12.5 1.5 16.4 8.4 12.4 1.6 16.4 8.4 12.2 1.6 16.8 7.6 315 10 307 165 -13.5 0 -13.2 -13.6 03/07/2007 19:50:00 14.3 1.8 19.1 9.1 14.2 1.8 19.1 8.8 13.9 2 19.5 8 310 11 297 165 -13.5 0 -13.4 -13.6 03/07/2007 20:00:00 14.7 1.3 18.3 11.1 14.6 1.3 17.6 11.5 14.3 1.5 17.9 10.3 310 12 298 165 -13.5 0 -13.2 -13.6 03/07/2007 20:10:00 13.8 1.3 16.8 9.5 13.6 1.4 16.8 9.9 13.5 1.3 16.1 9.9 316 9 286 165 -13.5 0 -13.4 -13.6 03/07/2007 20:20:00 13.6 1.9 18.7 9.5 13.5 1.8 18.7 9.5 13.1 1.9 18.3 8.4 312 12 284 165 -13.5 0 -13.2 -13.6 03/07/2007 20:30:00 13.2 1.4 16.8 9.1 13.1 1.5 16.4 9.1 12.2 1.5 16.1 8.4 311 13 312 165 -13.6 0 -13.4 -13.8 03/07/2007 20:40:00 14.2 1.7 18.7 9.1 14 1.7 18.7 9.1 13.7 1.5 17.9 9.5 313 11 306 165 -13.7 0 -13.6 -14 03/07/2007 20:50:00 15.1 1.1 17.9 12.2 14.9 1.1 17.9 11.8 14.3 1.5 18.3 9.9 310 8 302 165 -13.8 0 -13.6 -14 03/07/2007 21:00:00 16.3 1.3 20.2 12.2 16.1 1.3 19.9 11.5 15.9 1.4 19.1 11.8 314 7 304 165 -13.8 0 -13.6 -14 03/07/2007 21:10:00 14.4 1.6 17.9 9.5 14.3 1.6 17.6 9.5 13.7 1.7 17.6 8.8 309 13 311 165 -14 0 -13.8 -14 03/07/2007 21:20:00 13.4 1.7 17.2 8.8 13.2 1.7 17.6 9.1 12.3 1.8 16.4 8 311 10 313 165 -14.1 0 -14 -14.2 03/07/2007 21:30:00 11.8 1.3 15.6 7.6 11.6 1.2 15.3 7.6 10.9 1.5 14.9 6.1 315 12 318 165 -14.1 0 -14 -14.2 03/07/2007 21:40:00 14.2 2 19.5 7.2 14.1 2 19.1 8 13.6 2 18.7 8 320 12 325 165 -14.1 0 -14 -14.2 03/07/2007 21:50:00 15.8 1.7 19.9 10.3 15.7 1.7 19.5 11.1 15.5 1.7 19.5 11.1 319 9 318 165 -14.1 0 -14 -14.2 03/07/2007 22:00:00 16.8 1.5 21 13 16.6 1.5 21 12.6 16.5 1.7 20.6 12.2 318 8 305 165 -14.2 0 -14 -14.4 03/07/2007 22:10:00 17.8 1.7 21.8 13 17.6 1.7 21.4 12.6 17.4 1.7 21.8 12.6 316 7 306 165 -14.1 0 -14 -14.4 03/07/2007 22:20:00 16.3 1.5 19.9 12.6 16.2 1.5 19.9 12.6 16.1 1.7 20.2 9.5 316 8 309 165 -14.1 0 -14 -14.2 03/07/2007 22:30:00 15.5 1.5 19.1 11.8 15.2 1.5 18.7 11.5 14.8 1.7 19.1 10.3 316 7 312 165 -14.2 0 -14 -14.4 03/07/2007 22:40:00 15.2 1.3 18.7 11.5 14.9 1.3 18.7 11.5 14.3 1.4 17.6 10.3 313 8 300 165 -14.2 0 -14 -14.6 03/07/2007 22:50:00 15.5 1.3 18.7 11.5 15.3 1.2 18.3 11.8 14.6 1.6 18.3 8.8 312 8 319 165 -14.2 0 -14 -14.6 03/07/2007 23:00:00 18.6 1.5 21.8 13 18.4 1.5 21.8 13.3 18.3 1.7 22.6 12.6 315 6 317 165 -14.2 0 -14 -14.6 03/07/2007 23:10:00 19.4 1.3 22.1 15.6 19.3 1.3 22.1 15.6 19.1 1.5 22.9 13.7 313 6 315 165 -14.3 0 -14 -14.6 03/07/2007 23:20:00 19 1.1 21.8 16.1 18.8 1.1 21.8 16.1 18.6 1.4 21.4 13.7 314 7 310 165 -14.4 0 -14.4 -14.6 03/07/2007 23:30:00 19.8 1.6 22.9 15.6 19.7 1.6 22.9 15.6 19.6 1.8 23.3 12.6 313 8 312 165 -14.5 0 -14.4 -14.8 03/07/2007 23:40:00 19.5 1.5 24 14.9 19.5 1.4 24 14.9 19.7 1.5 23.7 14.9 315 7 307 165 -14.5 0 -14.4 -14.6 03/07/2007 23:50:00 20.7 1.4 24 16.1 20.6 1.4 24 16.4 20.7 1.7 24 14.5 313 7 300 165 -14.5 0 -14.4 -14.8 03/08/2007 00:00:00 20.6 1.5 23.7 16.8 20.6 1.5 23.7 15.6 20.7 1.5 23.7 16.4 313 6 302 165 -14.5 0 -14.4 -14.6 03/08/2007 00:10:00 20.9 1.5 24.4 14.9 20.8 1.5 24.8 14.9 20.7 1.7 25.2 15.6 311 7 310 165 -14.6 0 -14.4 -14.8 03/08/2007 00:20:00 21.2 1.8 24.8 16.1 21.1 1.8 24.4 16.4 21.1 2 25.2 14.9 312 8 302 165 -14.6 0 -14.6 -14.8 03/08/2007 00:30:00 20.5 1.6 24 16.4 20.5 1.5 24.4 16.8 20.5 1.7 25.2 15.6 313 8 310 165 -14.6 0 -14.6 -14.8 03/08/2007 00:40:00 18.3 1.6 21.8 13.3 18.2 1.7 22.1 13.3 17.7 1.7 21.4 13.3 311 9 304 165 -14.7 0 -14.6 -14.8 03/08/2007 00:50:00 16.3 1.6 19.9 9.9 16.2 1.7 19.9 9.9 15.4 1.7 19.9 10.3 310 9 319 165 -14.8 0 -14.6 -15 03/08/2007 01:00:00 12.8 2.2 16.8 7.2 12.6 2.2 16.8 7.6 11.2 2.3 15.6 4.6 307 11 306 165 -14.7 0 -14.6 -15 03/08/2007 01:10:00 14.7 1.5 18.7 11.1 14.6 1.5 18.3 10.3 14.3 1.5 17.9 9.9 315 8 313 165 -14.7 0 -14.6 -14.8 03/08/2007 01:20:00 12.9 1.7 17.2 8.4 12.8 1.7 16.8 8.8 12.2 1.7 16.8 6.8 317 9 314 165 -14.8 0 -14.6 -15 03/08/2007 01:30:00 11.3 1.7 14.9 7.2 11.2 1.6 14.9 6.1 9.6 1.9 14.5 4.9 307 14 313 165 -14.8 0 -14.8 -15 03/08/2007 01:40:00 11.2 1.6 16.1 8 11.1 1.5 15.6 8 10.3 1.7 15.6 6.5 314 9 316 165 -14.9 0 -14.8 -15 03/08/2007 01:50:00 11.7 1.5 15.3 7.2 11.6 1.5 14.9 7.6 10.9 1.7 14.9 5.3 313 10 324 165 -14.9 0 -14.8 -15.2 03/08/2007 02:00:00 13.3 1.3 16.8 9.5 13.1 1.3 16.8 9.9 12.6 1.6 16.4 7.6 313 8 314 165 -14.9 0 -14.8 -15.2 03/08/2007 02:10:00 14.1 1.5 17.6 9.9 13.9 1.5 17.6 9.9 13.6 1.6 17.9 9.5 312 9 301 165 -15 0 -15 -15.2 03/08/2007 02:20:00 12.5 1.7 16.4 9.1 12.4 1.7 16.4 9.1 11.7 2 16.8 6.1 313 9 318 165 -15 0 -15 -15.3 03/08/2007 02:30:00 13.2 2.4 17.2 6.5 13 2.4 17.2 6.5 12.6 2.3 17.2 7.6 315 8 310 165 -15.1 0 -15 -15.2 03/08/2007 02:40:00 12.6 1.3 16.4 9.1 12.4 1.4 16.4 8.8 12 1.5 15.3 7.6 316 10 310 165 -15.1 0 -15 -15.3 03/08/2007 02:50:00 10.2 1.5 15.3 6.8 10.1 1.5 14.9 6.5 9.8 1.3 13.3 6.5 323 16 301 165 -15.2 0 -15 -15.3 03/08/2007 03:00:00 8.9 1.1 12.2 6.8 8.7 1.3 12.2 4.9 8.4 1.2 12.2 5.3 339 10 341 165 -15.2 0 -15 -15.3 03/08/2007 03:10:00 8 0.9 10.7 5.7 7.7 1.1 10.3 4.2 7.8 0.8 10.3 5.7 336 11 319 165 -15.2 0 -15 -15.3 03/08/2007 03:20:00 9.9 1.3 13.7 6.5 9.7 1.5 13.7 6.1 9.8 1.3 13 6.5 342 9 344 165 -15.3 0 -15.2 -15.5 03/08/2007 03:30:00 10.7 1.2 14.9 7.6 10.2 1.7 14.9 5.7 10.8 1.5 15.3 7.2 343 8 344 165 -15.5 0 -15.3 -15.7 03/08/2007 03:40:00 10.8 1.4 14.5 7.6 10.4 1.6 14.5 6.8 11.2 1.5 15.3 7.2 340 11 332 165 -15.5 0 -15.5 -15.7 03/08/2007 03:50:00 11.3 1.3 16.1 8.4 10.7 1.5 14.5 6.1 11.5 1.3 14.9 8.4 343 9 327 165 -15.5 0 -15.5 -15.7 03/08/2007 04:00:00 10.1 1.2 14.5 7.2 10 1.3 14.1 6.8 10.2 1.3 13.7 7.2 336 10 336 165 -15.5 0 -15.3 -15.7 03/08/2007 04:10:00 11.3 1.3 15.3 8.4 11 1.4 14.9 7.6 11.2 1.5 16.1 7.6 326 15 322 165 -15.5 0 -15.3 -15.7 03/08/2007 04:20:00 10.8 1.3 15.3 6.8 10.7 1.2 14.9 6.8 10.6 1.2 13.7 7.6 319 11 292 165 -15.4 0 -15.3 -15.7 03/08/2007 04:30:00 10.4 1.2 14.1 6.8 10.3 1.1 14.1 6.8 10.1 1.2 13 6.5 322 12 315 165 -15.5 0 -15.3 -15.7 03/08/2007 04:40:00 11 1.2 14.9 8.4 10.9 1.1 14.5 8.4 11.1 1.1 14.1 8.8 326 11 329 165 -15.4 0 -15.3 -15.7 03/08/2007 04:50:00 10.5 1.2 14.1 8 10.5 1.1 14.1 7.6 10.3 1.3 15.3 7.2 321 11 321 165 -15.4 0 -15.3 -15.7 03/08/2007 05:00:00 10.2 1.1 12.6 6.8 10.2 1.1 13 6.8 10.3 1.2 13.3 6.8 321 9 310 165 -15.4 0 -15.3 -15.7 03/08/2007 05:10:00 9.5 1 12.6 7.2 9.5 1 12.2 7.2 9.3 1.1 12.6 6.1 321 9 329 165 -15.5 0 -15.3 -15.7 03/08/2007 05:20:00 9.5 0.8 12.2 7.2 9.4 0.9 11.8 7.2 9.3 0.9 12.2 6.5 325 9 326 165 -15.5 0 -15.5 -15.7 03/08/2007 05:30:00 11.2 1.5 14.9 8 11.1 1.5 14.9 7.6 11.1 1.5 14.9 8 320 10 317 165 -15.5 0 -15.3 -15.7 03/08/2007 05:40:00 11.6 1.2 14.5 8.4 11.5 1.2 14.5 8.8 11.4 1.3 14.5 8.4 323 8 328 165 -15.4 0 -15.3 -15.7 03/08/2007 05:50:00 10.9 1.2 14.5 7.6 10.8 1.2 14.5 8 10.7 1.2 15.3 7.6 321 10 316 165 -15.4 0 -15.3 -15.7 03/08/2007 06:00:00 11.3 1 14.1 8.4 11.2 1 14.5 8.4 11.2 1.1 14.5 7.6 322 9 332 165 -15.4 0 -15.3 -15.7 03/08/2007 06:10:00 11.6 1.3 16.1 8.4 11.6 1.3 15.6 8 11.7 1.5 16.4 8 325 8 306 165 -15.4 0 -15.3 -15.7 03/08/2007 06:20:00 13.3 1.5 17.2 9.5 13.1 1.6 16.8 9.5 13.3 1.7 20.2 8.8 323 8 329 165 -15.4 0 -15.2 -15.5 03/08/2007 06:30:00 13.5 1.2 16.8 10.3 13.4 1.3 16.8 10.3 13.3 1.2 16.8 10.3 318 8 316 165 -15.3 0 -15.2 -15.7 03/08/2007 06:40:00 13.9 1.5 18.7 10.3 13.8 1.6 18.7 10.3 14 1.7 18.3 9.1 318 7 328 165 -15.3 0 -15.2 -15.7 03/08/2007 06:50:00 13.3 1.2 17.2 10.3 13.2 1.3 16.8 9.9 13 1.2 16.1 9.1 317 8 314 165 -15.3 0 -15.2 -15.5 03/08/2007 07:00:00 13 1.2 16.8 9.5 13 1.3 16.8 9.5 12.8 1.2 16.4 8.8 314 8 303 165 -15.2 0 -15.2 -15.5 03/08/2007 07:10:00 10.4 1.3 14.5 6.5 10.3 1.3 14.1 6.5 9.9 1.4 14.1 6.5 313 8 288 165 -15.3 0 -15.2 -15.5 03/08/2007 07:20:00 9.2 1.3 12.6 5.3 9.1 1.3 12.6 5.7 8.4 1 11.1 6.1 307 12 297 165 -15.3 0 -15.2 -15.5 03/08/2007 07:30:00 8.5 1.2 13.3 5.7 8.5 1.3 13.3 5.7 8 1.2 12.6 4.9 318 17 310 165 -15.3 0 -15.2 -15.5 03/08/2007 07:40:00 9.8 1.3 12.6 5.7 9.2 1.6 12.6 4.6 10 1.7 13.7 4.9 335 18 354 165 -15.4 0 -15.3 -15.7 03/08/2007 07:50:00 9.2 1.5 14.5 5.7 9.2 1.4 14.1 5.3 8.8 1.2 13 6.1 312 15 296 165 -15.3 0 -15.2 -15.7 03/08/2007 08:00:00 12.2 1.5 16.1 8.8 12.2 1.5 16.4 9.1 10.3 1.5 14.5 6.5 301 11 302 165 -15.3 0 -15.2 -15.5 03/08/2007 08:10:00 13.4 1.8 17.2 8.4 13.3 1.8 17.6 8.4 11.5 1.5 16.4 8 306 11 293 165 -15.2 0 -15 -15.5 03/08/2007 08:20:00 13.7 1.8 19.1 9.5 13.7 1.8 19.1 9.1 11.4 1.8 18.7 7.6 302 12 307 165 -15.3 0 -15 -15.5 03/08/2007 08:30:00 15 1.9 21.4 10.7 14.9 2 21 10.7 12.6 1.9 19.9 8.4 301 11 274 165 -15.2 0 -15 -15.5 03/08/2007 08:40:00 15.5 2.1 20.6 10.3 15.4 2.2 21 9.9 12.7 2.4 21 7.6 298 13 292 165 -15.2 0 -15 -15.5 03/08/2007 08:50:00 14.9 2 19.5 8.4 14.8 2 19.5 8 12.1 2 17.9 8 297 12 310 165 -15.2 0 -15.2 -15.3 03/08/2007 09:00:00 15 2 20.2 9.9 15 2 20.2 9.5 12.4 2.1 19.1 7.2 296 14 285 165 -15.3 0 -15.2 -15.5 03/08/2007 09:10:00 15.9 2 21 9.9 15.9 2.1 21 10.3 13.2 1.9 19.1 9.1 298 12 293 165 -15.3 0 -15.2 -15.5 03/08/2007 09:20:00 15.4 1.9 19.5 10.3 15.3 1.9 19.1 9.9 12.3 1.9 18.3 7.2 293 13 300 165 -15.3 0 -15.2 -15.5 03/08/2007 09:30:00 14.9 2 21 9.5 14.8 2 20.6 9.1 11.7 1.7 19.1 7.2 291 12 293 165 -15.3 0 -15.2 -15.5 03/08/2007 09:40:00 13.8 2 19.1 7.6 13.6 2 19.1 6.8 11.4 1.7 16.4 6.1 298 13 297 165 -15.2 0 -15 -15.5 03/08/2007 09:50:00 13.6 1.7 18.7 9.1 13.6 1.7 18.7 8.4 11.2 1.9 18.3 7.2 290 12 288 165 -15 0 -14.8 -15.2 03/08/2007 10:00:00 14 1.7 19.1 8.4 13.9 1.7 18.3 8.4 11.1 1.7 17.6 6.8 288 11 280 165 -15 0 -14.8 -15.2 03/08/2007 10:10:00 13.5 1.6 17.2 8.4 13.5 1.7 17.6 8.4 11.2 2 17.2 6.5 288 12 286 165 -14.9 0 -14.6 -15.2 03/08/2007 10:20:00 13.4 1.8 18.7 6.8 13.4 1.8 19.1 7.2 11.5 1.9 16.8 5.7 287 13 273 165 -14.9 0 -14.8 -15.2 03/08/2007 10:30:00 12.7 1.5 16.4 8 12.6 1.6 16.1 8 10.7 1.7 16.1 6.8 288 13 292 165 -14.7 0 -14.6 -15 03/08/2007 10:40:00 12.5 1.8 17.9 6.5 12.5 1.8 17.9 6.8 10.7 1.7 16.8 5.3 292 15 285 165 -14.7 0 -14.6 -14.8 03/08/2007 10:50:00 12.3 1.7 17.2 7.6 12.3 1.8 17.2 7.6 10.9 1.9 17.6 5.7 289 14 274 165 -14.5 0 -14.2 -14.8 03/08/2007 11:00:00 12.1 1.5 16.8 6.8 11.9 1.5 16.1 7.2 10.2 1.3 14.5 6.8 295 13 297 165 -14.4 0.1 -14.2 -14.8 03/08/2007 11:10:00 11.7 1.5 15.6 7.6 11.6 1.5 15.6 7.6 10.3 1.5 16.1 7.2 298 17 269 165 -14.1 0 -14 -14.6 03/08/2007 11:20:00 11.4 2.2 16.8 6.8 11.4 2.2 17.2 6.8 10.4 2 17.9 6.8 293 17 243 165 -14.2 0.1 -14 -14.4 03/08/2007 11:30:00 9.8 1.7 16.8 4.6 9.7 1.7 16.4 4.6 8.7 1.7 14.1 3.4 296 18 316 165 -13.9 0 -13.6 -14.2 03/08/2007 11:40:00 11.5 2.1 17.9 6.8 11.4 2.1 17.9 7.2 10.1 1.7 14.9 5.7 296 18 279 165 -13.7 0 -13.6 -14 03/08/2007 11:50:00 12 1.9 15.6 6.5 11.8 1.9 15.6 6.1 11.1 2 16.1 4.9 303 18 263 165 -13.6 0 -13.6 -14 03/08/2007 12:00:00 11.2 1.8 17.2 5.7 11.1 1.7 16.4 5.7 10 1.7 14.1 4.9 303 19 290 165 -13.5 0 -13.2 -13.8 03/08/2007 12:10:00 12.8 2 18.7 8 12.6 2 18.3 7.6 11.6 1.9 17.9 7.2 303 18 277 165 -13.2 0 -13.2 -13.6 03/08/2007 12:20:00 13.3 2.1 21.4 8.4 13.2 2.1 21 8 11.6 1.9 18.7 7.2 303 11 297 165 -13.2 0 -13.2 -13.6 03/08/2007 12:30:00 13 1.8 17.9 9.1 12.9 1.8 17.6 9.1 10.7 1.9 16.1 6.8 295 10 293 165 -13.5 0 -13.2 -13.6 03/08/2007 12:40:00 12.9 1.8 17.6 8.4 12.8 1.8 17.2 8 10.8 2 17.2 6.8 296 11 304 165 -13.6 0.1 -13.4 -13.8 03/08/2007 12:50:00 12.9 2 17.9 7.2 12.8 2 17.2 7.6 11.2 1.9 17.9 6.8 303 12 300 165 -13.2 0.1 -13 -13.6 03/08/2007 13:00:00 14.3 2 19.1 9.9 14 2 18.7 9.1 12.6 2.1 18.3 8.4 306 11 314 165 -13.2 0.1 -13 -13.6 03/08/2007 13:10:00 15 1.8 21 10.7 14.8 1.8 20.6 9.9 13.8 1.9 20.6 9.9 308 8 310 165 -13 0 -13 -13.2 03/08/2007 13:20:00 17.4 2.2 23.7 13 17.2 2.1 23.3 12.6 16 2.3 24 11.8 308 9 324 165 -13 0 -12.8 -13.4 03/08/2007 13:30:00 21.1 2.1 25.6 15.3 20.9 2.1 25.2 15.3 18.5 2 24.4 12.2 301 10 298 165 -13.2 0.1 -12.8 -13.4 03/08/2007 13:40:00 21.5 1.8 26 14.1 21.4 1.8 25.6 13.7 18.7 2 24.4 12.2 299 9 297 165 -13.2 0 -13.2 -13.4 03/08/2007 13:50:00 19.8 2 24.4 14.1 19.6 2 24.4 14.5 17.6 2 23.3 12.6 301 10 286 165 -13.1 0 -13 -13.6 03/08/2007 14:00:00 19.1 1.9 23.7 13.7 18.8 1.9 22.9 13.7 17.6 2.2 22.6 11.1 306 9 302 165 -12.9 0 -12.6 -13.2 03/08/2007 14:10:00 19.9 2.3 24.4 13 19.5 2.3 23.7 12.6 17.7 2.6 23.3 10.7 304 9 308 165 -13 0 -12.8 -13.2 03/08/2007 14:20:00 21.7 1.9 25.6 16.1 21.5 1.9 24.8 15.6 19.7 2.2 24.8 14.9 301 9 310 165 -13.1 0 -12.8 -13.2 03/08/2007 14:30:00 23.6 2.4 29.1 16.4 23.4 2.4 28.7 16.4 21.5 2.5 27.1 14.5 299 9 298 165 -13.1 0 -13 -13.4 03/08/2007 14:40:00 21.9 2.1 26.8 15.6 21.7 2.1 26.3 15.3 19.8 2.4 26 13 300 9 301 165 -12.9 0 -12.6 -13.2 03/08/2007 14:50:00 21.9 2.1 26 15.6 21.6 2.1 26 16.1 19.4 2.4 24.8 13.3 298 9 294 165 -12.9 0 -12.8 -13 03/08/2007 15:00:00 23.6 2 28.3 17.6 23.5 2 27.9 17.2 21.1 2.2 26.8 16.1 297 9 297 165 -12.9 0 -12.6 -13.2 03/08/2007 15:10:00 24.8 2.2 30.2 17.6 24.7 2.2 29.4 17.9 22.6 2.4 27.9 15.6 297 10 302 165 -12.8 0 -12.6 -13.2 03/08/2007 15:20:00 25.3 2.1 29.1 17.6 25.2 2.1 29.1 17.6 23 2.5 27.9 14.9 296 9 291 165 -12.8 0 -12.6 -13.2 03/08/2007 15:30:00 25 2.3 29.8 18.3 25.1 2.4 29.8 18.3 22.8 2.5 27.9 16.4 293 10 288 165 -12.7 0 -12.6 -13 03/08/2007 15:40:00 25.7 1.8 29.8 19.1 25.8 1.9 29.8 18.7 23.2 2.4 27.9 16.1 293 9 291 165 -12.8 0 -12.6 -13 03/08/2007 15:50:00 25.2 2.3 29.8 16.4 25.2 2.4 29.4 17.2 22.6 2.4 28.7 14.5 291 10 290 165 -12.8 0 -12.6 -13.2 03/08/2007 16:00:00 24.7 2.3 30.2 17.9 24.8 2.3 30.2 17.9 21.8 2.6 27.1 14.1 289 12 292 165 -12.7 0 -12.6 -13 03/08/2007 16:10:00 24.3 2.5 29.8 16.4 24.4 2.6 29.8 16.1 21.4 2.8 29.4 13 292 10 300 165 -12.7 0 -12.4 -13 03/08/2007 16:20:00 24.7 2.3 29.4 16.8 24.7 2.3 29.8 16.8 21.8 2.6 28.7 14.5 289 11 293 165 -12.7 0 -12.6 -13 03/08/2007 16:30:00 26.4 2.2 30.9 19.5 26.5 2.3 31.8 19.5 23.6 2.4 29.4 17.6 287 10 286 165 -12.7 0 -12.6 -13 03/08/2007 16:40:00 26.5 1.7 29.4 19.9 26.7 1.7 30.2 19.9 23.6 2 27.5 17.6 287 9 296 165 -12.6 0 -12.6 -12.8 03/08/2007 16:50:00 26.7 1.7 30.6 20.6 26.8 1.8 30.6 20.2 23.5 2.4 27.9 16.1 286 10 293 165 -12.6 0 -12.4 -13 03/08/2007 17:00:00 26.3 2 29.8 19.9 26.4 2.1 30.2 20.2 23.2 2.6 28.7 15.6 286 9 263 165 -12.6 0 -12.4 -12.8 03/08/2007 17:10:00 25.6 2.3 29.1 17.9 25.7 2.4 29.4 17.6 23.2 2.9 28.7 14.1 286 10 292 165 -12.5 0 -12.4 -12.8 03/08/2007 17:20:00 26.9 2.1 31.8 19.5 27 2.2 32.1 19.9 24.3 2.7 29.1 16.1 284 10 281 165 -12.5 0.1 -12.4 -13 03/08/2007 17:30:00 26.2 2 30.2 20.2 26.3 2.1 30.9 20.2 23.2 2.7 31.8 14.9 289 9 295 165 -12.4 0 -12.2 -12.6 03/08/2007 17:40:00 26.1 1.9 30.2 21 26.2 1.9 30.6 21 22.9 2.5 30.9 16.1 288 9 285 165 -12.4 0 -12.2 -12.6 03/08/2007 17:50:00 26.1 1.7 29.8 19.9 26.2 1.8 30.6 19.9 23.3 2.6 28.7 15.6 286 8 266 165 -12.4 0 -12.2 -12.6 03/08/2007 18:00:00 25.5 2.3 31.8 18.7 25.6 2.4 32.1 19.1 22.8 2.8 28.7 14.9 287 10 293 165 -12.3 0 -12.2 -12.6 03/08/2007 18:10:00 27.1 2.2 32.1 18.3 27.2 2.3 32.1 18.7 23.9 2.7 29.8 14.5 288 10 289 165 -12.3 0 -12.2 -12.6 03/08/2007 18:20:00 27.7 2.1 32.4 20.2 27.8 2.1 32.9 19.5 24.4 2.3 29.4 18.3 287 10 292 165 -12.1 0 -12 -12.6 03/08/2007 18:30:00 26 2.8 31.8 16.1 25.9 2.9 30.9 16.4 22.5 3.3 28.7 13 287 11 291 165 -12 0 -11.8 -12.4 03/08/2007 18:40:00 22.4 2.8 28.3 15.3 22.1 2.8 27.5 14.5 18.2 2.6 27.9 11.1 291 12 288 165 -12 0 -11.8 -12.2 03/08/2007 18:50:00 19.7 2.7 26.8 12.6 19.5 2.6 26.3 12.2 15.4 2.7 22.9 8.4 294 15 289 165 -12.1 0 -12 -12.4 03/08/2007 19:00:00 19.7 2.6 29.4 13 19.5 2.6 28.3 12.2 16.3 2.7 26 9.1 298 15 294 165 -11.9 0 -11.8 -12.4 03/08/2007 19:10:00 22.3 2.7 27.1 13.7 21.9 2.6 27.5 13.7 17.9 2.5 26 10.7 291 12 290 165 -11.9 0.1 -11.8 -12.2 03/08/2007 19:20:00 21.5 3.2 28.3 11.5 21.2 3.1 27.9 11.5 17.3 3.3 24.8 8.4 295 13 299 165 -11.8 0 -11.8 -11.8 03/08/2007 19:30:00 18.7 2.9 25.2 11.5 18.5 2.9 25.2 11.5 14.2 2.9 21.4 4.6 297 14 306 165 -11.8 0 -11.6 -12 03/08/2007 19:40:00 19.7 2.7 26.8 12.2 19.5 2.6 26.3 11.8 16.2 2.6 22.9 9.1 297 14 295 165 -11.8 0 -11.6 -12 03/08/2007 19:50:00 19.7 2.7 25.6 11.5 19.4 2.6 25.6 11.8 16.2 2.4 24.4 9.9 296 13 339 165 -11.4 0.2 -11 -12 03/08/2007 20:00:00 19.4 3.1 26 10.3 19.1 2.9 25.6 9.5 15.1 2.9 22.1 4.9 292 15 291 165 -11.5 0.1 -11.4 -11.6 03/08/2007 20:10:00 14.6 3.1 23.3 7.6 14.5 3.1 22.6 7.2 11.6 2.8 19.9 5.3 299 19 273 165 -10.6 0.3 -10.2 -11.4 03/08/2007 20:20:00 15.6 2.9 23.3 5.3 15.4 2.9 22.6 5.3 12.2 2.7 19.5 3 304 20 328 165 -10.6 0.2 -10.2 -11.2 03/08/2007 20:30:00 18.7 2.9 29.4 8 18.5 2.9 29.1 8.4 15.4 3.2 27.9 8.4 298 15 283 165 -10.7 0.2 -10.4 -11.2 03/08/2007 20:40:00 20.9 2.3 27.5 12.6 20.7 2.3 27.9 14.5 16.8 2.3 23.7 10.7 294 11 308 165 -10.9 0 -10.6 -11.2 03/08/2007 20:50:00 19.8 2.6 28.7 13 19.5 2.5 28.7 12.6 16 2.6 23.7 9.5 294 12 295 165 -10.8 0.1 -10.4 -11.2 03/08/2007 21:00:00 20.5 2.4 29.8 14.5 20.2 2.3 29.1 14.5 17.8 2.4 28.3 11.1 300 14 302 165 -10.6 0 -10.6 -11 03/08/2007 21:10:00 21.9 2.4 28.3 15.3 21.6 2.4 27.9 15.3 17.8 2.4 25.6 10.3 294 10 288 165 -10.4 0.2 -9.7 -10.8 03/08/2007 21:20:00 21.9 2.6 29.8 15.3 21.6 2.6 29.4 15.3 18.3 2.6 25.6 11.1 298 12 297 165 -10.2 0.1 -10 -10.6 03/08/2007 21:30:00 23 2.4 29.1 15.3 22.7 2.3 29.1 15.6 18.6 2.4 26 12.6 295 10 310 165 -10.4 0 -10.2 -10.6 03/08/2007 21:40:00 23.9 2.9 30.9 15.6 23.6 2.9 30.2 15.3 20.2 2.8 26.8 12.2 290 13 278 165 -10.5 0 -10.4 -10.8 03/08/2007 21:50:00 25.2 2.4 30.9 16.4 25 2.4 31.3 16.1 21.1 2.4 27.9 13 293 10 274 165 -10.6 0 -10.4 -11 03/08/2007 22:00:00 25.9 2.1 30.2 18.3 25.8 2.2 29.8 17.9 22.5 2.6 29.4 16.1 293 10 307 165 -10.5 0 -10.4 -10.8 03/08/2007 22:10:00 26 2.2 30.9 19.1 25.9 2.2 30.6 18.3 22.2 2.6 27.9 16.1 295 8 298 165 -10.5 0 -10.4 -10.8 03/08/2007 22:20:00 25.8 1.8 32.4 21 25.7 1.8 31.3 20.6 22.4 2.2 28.7 17.2 297 9 299 165 -10.4 0 -10.4 -10.8 03/08/2007 22:30:00 22.8 2.3 29.4 16.1 22.6 2.3 29.1 15.6 20.2 2 29.1 15.3 301 12 289 165 -10.5 0 -10.4 -10.8 03/08/2007 22:40:00 21.7 3.1 28.7 13 21.5 3.1 29.1 13 20.3 2.9 27.5 13.7 309 11 304 165 -10.3 0.1 -10 -10.6 03/08/2007 22:50:00 23 2.8 29.4 16.1 22.8 2.7 29.4 15.3 21.5 2.7 29.8 13.7 306 12 296 165 -10.2 0.1 -9.7 -10.4 03/08/2007 23:00:00 23.3 2.6 30.9 16.1 23.1 2.5 30.6 16.1 20.8 2.7 29.4 13 301 13 287 165 -10.3 0 -10.2 -10.6 03/08/2007 23:10:00 23 2.4 30.9 15.6 22.8 2.4 30.2 14.9 19.7 2.8 26.8 13 298 12 293 165 -10.3 0.1 -10 -10.6 03/08/2007 23:20:00 23.6 2.6 29.4 16.4 23.5 2.6 29.4 17.2 19.9 2.8 28.3 14.5 289 11 304 165 -10.2 0 -10.2 -10.4 03/08/2007 23:30:00 23.9 2.8 30.2 15.3 23.8 2.8 29.8 15.6 20.4 2.9 28.3 12.2 290 11 297 165 -10.2 0 -10 -10.4 03/08/2007 23:40:00 22 2.7 27.5 15.3 21.9 2.7 26.8 14.5 18.8 2.6 26.8 12.2 297 13 246 165 -10.2 0 -10 -10.4 03/08/2007 23:50:00 22.1 2.7 30.6 15.6 21.9 2.8 30.9 15.3 20 2.9 30.9 14.1 306 14 314 165 -9.6 0.4 -8.9 -10.2 03/09/2007 00:00:00 24.3 2.5 32.1 17.9 24.3 2.5 32.4 17.9 23.2 2.8 32.4 16.4 305 9 311 165 -9.5 0.1 -9.1 -10 03/09/2007 00:10:00 25.2 2.4 30.2 17.2 25.2 2.4 30.2 17.6 23.2 2.5 29.1 16.8 299 11 258 165 -10.1 0.1 -9.7 -10.2 03/09/2007 00:20:00 26.2 2.4 31.3 18.3 26.2 2.4 31.3 17.9 22.7 2.4 29.4 16.1 293 10 287 165 -10.1 0.1 -9.7 -10.4 03/09/2007 00:30:00 22.1 2.8 28.7 14.5 21.9 2.8 28.7 14.5 20.1 2.7 29.1 13.7 305 12 303 165 -10 0 -9.7 -10.2 03/09/2007 00:40:00 22.3 2.4 27.9 16.1 22.1 2.4 27.5 16.1 19.9 2.7 26 13 305 13 276 165 -9.7 0 -9.7 -10.2 03/09/2007 00:50:00 22.8 2.4 28.7 15.3 22.6 2.4 28.3 14.9 21.2 2.3 28.3 14.9 310 13 296 165 -9.4 0.1 -9.1 -10 03/09/2007 01:00:00 25.9 2.7 32.9 18.3 25.8 2.7 32.9 17.9 25 2.9 32.1 16.1 308 10 292 165 -9.3 0.1 -8.9 -9.7 03/09/2007 01:10:00 26.2 2.4 34.8 20.2 26.2 2.4 34.4 20.6 25.1 2.6 32.9 16.4 305 10 298 165 -9.2 0.1 -8.9 -9.7 03/09/2007 01:20:00 26.5 2.5 36.3 19.1 26.5 2.5 35.9 19.1 25.2 2.8 33.6 17.9 306 12 316 165 -8.9 0.2 -8.3 -9.3 03/09/2007 01:30:00 25.2 2.3 32.9 19.5 25.1 2.3 33.2 19.5 24.1 2.7 32.4 16.8 309 10 326 165 -8.7 0.2 -8.3 -9.1 03/09/2007 01:40:00 24.6 2.7 31.8 14.9 24.5 2.7 30.6 14.5 23.1 2.9 31.3 14.5 307 10 299 165 -8.4 0.2 -8.1 -8.9 03/09/2007 01:50:00 26 2.6 34.4 19.1 25.9 2.6 34 19.1 24.5 2.9 34.8 17.2 306 9 310 165 -8.6 0.1 -8.1 -8.9 03/09/2007 02:00:00 24.4 2.6 30.9 16.4 24.4 2.6 30.9 16.8 23.4 2.7 31.3 16.8 310 14 309 165 -8.4 0.1 -8.1 -8.9 03/09/2007 02:10:00 24.6 2.6 31.3 17.9 24.5 2.7 31.8 17.6 23.7 2.7 30.9 16.8 309 11 298 165 -8.5 0 -8.5 -8.7 03/09/2007 02:20:00 23.4 2.7 29.8 16.8 23.4 2.7 30.2 16.8 22.5 2.9 28.7 14.9 312 13 306 165 -8.3 0.1 -8.1 -8.7 03/09/2007 02:30:00 24.5 2.6 32.9 17.2 24.4 2.5 31.8 16.8 23.3 2.7 30.9 14.1 308 9 298 165 -8 0.2 -7.2 -8.5 03/09/2007 02:40:00 23.8 2.8 29.4 13.3 23.7 2.8 29.8 13.3 22.1 3.5 30.6 9.9 308 12 313 165 -7.1 0.5 -6.4 -8.1 03/09/2007 02:50:00 17.5 2.9 26 11.5 17 3.1 26 9.9 16.2 2.8 26 9.1 323 19 326 165 -6.5 0.4 -5.7 -7.2 03/09/2007 03:00:00 17.5 2.2 23.3 11.8 17.1 2.3 23.3 10.7 16.9 2.3 22.6 10.3 332 15 332 165 -5.6 0.1 -5.3 -5.9 03/09/2007 03:10:00 19.4 2.8 26.3 12.6 18.1 3.2 27.5 10.3 19.5 3.1 27.9 12.2 343 12 349 165 -5.5 0 -5.3 -5.7 03/09/2007 03:20:00 15.6 2.4 22.1 8.8 14.4 2.3 20.6 8.4 15.1 2.4 21.8 9.5 342 15 351 165 -6 0.3 -5.5 -6.4 03/09/2007 03:30:00 17.5 3.1 27.1 11.1 16.8 2.9 27.9 10.3 17 3.5 26.8 10.7 336 13 344 165 -6 0.2 -5.7 -6.6 03/09/2007 03:40:00 18.1 2.6 26 12.2 17.9 2.6 26.8 11.5 17.7 2.8 27.9 9.9 333 12 341 165 -6.6 0.1 -6.4 -6.8 03/09/2007 03:50:00 17.7 2.2 24.4 12.6 17.5 2.3 24.8 11.8 16.9 2.2 23.7 12.2 325 12 328 165 -6.7 0 -6.4 -7 03/09/2007 04:00:00 19 2.5 27.9 13.3 18.8 2.5 27.5 12.6 18.2 2.8 27.1 13 321 9 323 165 -6.6 0.1 -6.1 -6.8 03/09/2007 04:10:00 19.9 2.6 27.1 12.6 19.6 2.7 28.7 12.2 19.3 2.8 27.1 13.7 326 13 333 165 -6.7 0 -6.6 -7.2 03/09/2007 04:20:00 22.2 3.3 30.2 12.6 22.1 3.5 30.9 13 21.9 3.6 30.9 12.6 332 11 338 165 -6.7 0 -6.6 -7 03/09/2007 04:30:00 23.3 2.8 31.3 15.3 23.1 2.9 32.4 16.1 22.9 3.1 30.2 15.6 334 8 349 165 -6.7 0 -6.6 -6.8 03/09/2007 04:40:00 21.2 2.8 27.9 13 20.8 2.8 27.1 12.6 20.6 3.1 27.5 13 333 9 326 165 -6.2 0.3 -5.7 -6.8 03/09/2007 04:50:00 19.5 2.7 25.2 10.7 19.3 2.9 25.6 10.3 19 2.8 24 10.7 339 8 334 165 -6 0.1 -5.7 -6.4 03/09/2007 05:00:00 17.8 2.5 25.2 12.6 17.7 2.6 24.4 11.5 17.7 2.7 25.2 11.5 337 8 336 165 -5.6 0 -5.5 -6.1 03/09/2007 05:10:00 15.4 2.5 21 8.8 15.2 2.5 21 8.8 14.8 2.5 22.1 9.9 327 11 331 165 -5.6 0.2 -5.3 -6.1 03/09/2007 05:20:00 13.8 2.1 20.2 8.8 13.4 2.2 19.9 6.8 13.2 2.1 19.5 9.1 331 14 328 165 -6.2 0.1 -5.7 -6.6 03/09/2007 05:30:00 13.8 2.4 19.1 7.6 13.8 2.6 19.5 6.5 13.4 2.7 19.1 6.1 333 12 347 165 -5.8 0 -5.7 -6.1 03/09/2007 05:40:00 15.3 1.8 19.9 8.8 15.2 1.8 19.5 9.1 14.5 2.3 20.2 8.8 319 13 314 165 -6.1 0.3 -5.5 -6.6 03/09/2007 05:50:00 14.2 1.9 18.3 7.6 14.1 1.8 18.3 7.6 13.6 2.3 18.3 7.6 324 13 313 165 -6.6 0 -6.1 -6.8 03/09/2007 06:00:00 13.7 2.2 19.1 8 13.5 2.3 19.1 7.6 12.5 2.1 17.6 7.2 318 16 306 165 -6.6 0.1 -6.4 -6.8 03/09/2007 06:10:00 15.3 2.3 22.6 7.6 15.1 2.3 22.9 7.6 14.3 2.6 21.4 7.2 317 12 325 165 -6.5 0.2 -6.1 -6.8 03/09/2007 06:20:00 17.2 3.1 23.3 9.5 17 3.1 23.3 9.1 15.5 2.9 22.9 9.1 313 15 309 165 -6.4 0 -6.1 -6.8 03/09/2007 06:30:00 18.6 2.2 25.6 13.3 18.4 2.2 25.6 13.3 17.6 2.2 23.7 12.2 318 12 295 165 -6.4 0 -6.1 -6.6 03/09/2007 06:40:00 17.2 1.9 21.8 11.8 17.1 1.8 21 11.1 16.7 1.9 20.6 12.6 323 10 332 165 -6 0.2 -5.7 -6.6 03/09/2007 06:50:00 18.4 2.2 23.7 13.7 18.2 2.4 24 13 18.1 2.4 24.8 12.6 333 12 350 165 -5.7 0.3 -5 -6.1 03/09/2007 07:00:00 18.5 2.7 24.8 10.3 18.4 2.8 24.8 9.5 17.8 3.1 25.2 10.7 330 12 332 165 -5.6 0.1 -5.3 -5.9 03/09/2007 07:10:00 18 2 25.2 11.8 17.9 2.1 25.6 11.5 17.4 2 24.4 11.5 331 11 345 165 -5.6 0.1 -5.5 -5.7 03/09/2007 07:20:00 18.7 2.1 24.8 13.3 18.6 2.3 24.8 13.3 18.4 2.4 25.6 12.2 334 11 332 165 -5.8 0 -5.7 -5.9 03/09/2007 07:30:00 19.6 2.1 26.3 15.3 19.5 2.1 26.8 14.9 18.7 2.2 24.4 13.7 319 10 317 165 -6.1 0 -5.7 -6.4 03/09/2007 07:40:00 19.1 2.6 26 12.2 18.6 2.6 26.3 11.8 18.1 2.9 26 12.2 328 15 333 165 -6.3 0 -6.1 -6.6 03/09/2007 07:50:00 19.2 1.8 24.8 14.1 19.1 1.9 24.4 14.1 18.6 1.9 26 13.7 329 12 325 165 -6.4 0 -6.1 -6.6 03/09/2007 08:00:00 19 1.7 23.3 13 18.8 1.7 23.3 13.7 18.4 2.1 24.4 13.7 326 10 321 165 -6.4 0 -6.1 -6.6 03/09/2007 08:10:00 17.5 2 24 11.8 17.4 2.1 23.7 11.1 17.1 2.1 23.3 11.8 331 11 334 165 -6.2 0 -6.1 -6.6 03/09/2007 08:20:00 18.5 1.7 23.7 14.1 18.3 1.8 23.7 14.1 18.3 2 23.3 11.5 332 9 338 165 -6.1 0 -5.9 -6.4 03/09/2007 08:30:00 19.2 2.1 26 14.1 19 2.3 26.3 13.7 18.6 2.4 26 13 331 13 344 165 -6 0 -5.7 -6.1 03/09/2007 08:40:00 19.2 2.4 24.8 13 18.9 2.3 25.2 13 18.5 2.2 23.3 12.6 328 15 312 165 -5.9 0 -5.7 -6.1 03/09/2007 08:50:00 17.6 2.1 22.6 11.5 17.4 2.1 22.1 11.8 17.2 2 22.1 11.5 327 10 326 165 -5.8 0 -5.5 -6.1 03/09/2007 09:00:00 19.5 1.9 25.6 14.1 18.9 2 25.2 13.3 19.2 2.2 26.8 13 340 10 349 165 -5.6 0 -5.3 -5.9 03/09/2007 09:10:00 19 2 24.8 14.1 18.6 2.1 23.3 13 18.9 2 23.7 13.3 338 9 355 165 -5.4 0.1 -5 -5.7 03/09/2007 09:20:00 19 2.5 25.6 12.2 18.8 2.8 26.3 7.6 19 2.6 26.3 13 338 9 349 165 -4.9 0 -4.6 -5.3 03/09/2007 09:30:00 19.3 2.1 26.8 14.5 18.3 2.2 24.8 12.6 19.2 2.4 26.3 14.1 344 11 353 165 -4.7 0.1 -4.4 -4.8 03/09/2007 09:40:00 18.5 2.7 28.3 12.6 17.9 2.9 26.3 11.5 18.1 2.8 27.5 11.8 339 10 348 165 -4.1 0.3 -3.5 -4.6 03/09/2007 09:50:00 20.6 2.6 29.4 13.3 20.2 2.9 28.7 11.5 20.9 2.5 29.8 14.5 342 9 349 165 -4.1 0.1 -3.7 -4.4 03/09/2007 10:00:00 18 2.7 25.2 12.2 17.2 2.9 25.6 10.3 17.5 3.2 27.5 10.7 341 11 341 165 -4.2 0.1 -3.9 -4.4 03/09/2007 10:10:00 16.9 2.3 22.6 10.3 16.4 2.6 22.6 9.9 16.7 2.5 23.3 10.7 333 12 329 165 -4.2 0.1 -3.7 -4.6 03/09/2007 10:20:00 17.3 2.1 23.3 12.2 17.1 2.1 22.9 12.2 16.3 2.3 22.9 11.1 320 12 320 165 -3.7 0 -3.5 -4.2 03/09/2007 10:30:00 17.5 1.9 21.8 11.1 17 2.1 21.4 10.3 17.1 2.1 21.8 11.5 330 13 352 165 -4 0.1 -3.7 -4.4 03/09/2007 10:40:00 18.3 2 23.3 11.5 18.2 1.9 22.9 12.2 17 1.9 21.8 12.2 315 13 290 165 -4.4 0.2 -3.9 -4.6 03/09/2007 10:50:00 20.7 2.3 26.3 14.5 20.6 2.3 26 14.1 18.5 2.5 25.2 11.5 308 10 302 165 -4.8 0.1 -4.2 -5 03/09/2007 11:00:00 22.1 1.9 26.8 17.2 21.9 1.9 26.8 17.2 20 2.6 26.8 13.7 307 8 318 165 -4.9 0.1 -4.4 -5.3 03/09/2007 11:10:00 20.3 1.9 25.2 15.3 20 1.8 24.8 16.1 19.2 1.9 23.3 13 320 12 332 165 -4.7 0.1 -4.4 -5 03/09/2007 11:20:00 20.5 1.8 25.2 15.3 20.3 1.8 25.6 15.3 19.7 2.1 24.8 14.5 324 12 316 165 -4.5 0.1 -4.4 -4.8 03/09/2007 11:30:00 20.9 2.2 27.1 15.6 20.6 2.2 27.5 15.3 20.3 2.1 26 15.3 321 10 315 165 -4.6 0 -4.4 -4.6 03/09/2007 11:40:00 21.1 2 28.3 16.4 20.9 2 27.5 15.3 20.1 2.1 26.8 13.3 316 12 332 165 -4.4 0.1 -3.9 -4.6 03/09/2007 11:50:00 20.1 2.1 26 14.5 19.9 2.1 26 14.1 19.2 2.3 26.3 13 320 13 305 165 -4.1 0.1 -3.9 -4.4 03/09/2007 12:00:00 20.4 2.5 27.9 14.1 20.2 2.5 29.8 13 19.6 2.8 28.3 9.9 320 11 264 165 -4.3 0 -3.9 -4.6 03/09/2007 12:10:00 20.4 2.6 29.1 13.7 20.1 2.6 29.4 13 19.1 2.5 25.6 11.5 319 15 295 165 -4.9 0.1 -4.6 -5.3 03/09/2007 12:20:00 18.4 2.1 24.4 13 18.2 2.1 24.8 13 17.7 2.1 22.9 13 321 10 317 165 -5.2 0.1 -5 -5.3 03/09/2007 12:30:00 17.5 1.8 22.6 13 17.4 1.8 22.6 13.3 17.3 1.8 22.6 12.6 332 11 333 165 -5.2 0 -5 -5.3 03/09/2007 12:40:00 18.5 2.4 26.8 13.7 18.4 2.3 26.3 13.7 18.4 2.5 27.9 13.3 330 7 334 165 -5.2 0.1 -5 -5.3 03/09/2007 12:50:00 20 2.2 26.3 14.5 19.9 2.2 26.8 14.5 20.2 2.4 27.5 12.6 335 8 340 165 -5.2 0 -5 -5.5 03/09/2007 13:00:00 19.8 1.9 27.1 13.3 19.9 2 27.5 14.5 20.1 1.9 24 14.1 336 7 340 165 -5.3 0.1 -5 -5.5 03/09/2007 13:10:00 19.8 2 25.6 15.3 19.9 2.1 25.6 14.5 19.8 2.1 25.2 14.9 338 6 338 165 -5.2 0.1 -5 -5.7 03/09/2007 13:20:00 19.8 1.9 24.4 13.7 19.8 2 24.4 13.7 20 2 25.2 13.7 334 8 333 165 -5.3 0 -5 -5.5 03/09/2007 13:30:00 18.1 2.6 24 11.5 18.1 2.6 24 11.1 18.2 2.6 24.4 11.5 336 10 333 165 -4.9 0 -4.6 -5.3 03/09/2007 13:40:00 16.3 2.6 23.3 10.3 16.2 2.7 22.9 10.3 16.4 2.6 24 9.9 339 10 333 165 -4.9 0 -4.6 -5 03/09/2007 13:50:00 15.2 2.2 21.8 10.7 15.1 2.4 22.9 10.7 15.4 2.4 22.6 9.9 338 9 333 165 -4.7 0.1 -4.4 -5.3 03/09/2007 14:00:00 16.7 2 21.4 11.1 16.7 2.2 22.6 10.3 16.9 2.3 23.3 11.8 338 9 332 165 -4.8 0.1 -4.4 -5.3 03/09/2007 14:10:00 15.9 2.1 21 11.1 15.4 2.5 21 9.1 16.3 2.3 22.1 11.1 338 12 338 165 -4.9 0 -4.4 -5 03/09/2007 14:20:00 16.8 2.4 23.7 8.4 16.6 2.5 24.8 9.1 16.9 2.6 24.4 8.8 335 10 336 165 -4.4 0.1 -4.2 -4.8 03/09/2007 14:30:00 15.2 2.5 21 8 14.6 2.6 20.6 7.2 15.3 2.5 21.4 8.8 340 12 336 165 -4.2 0.1 -3.9 -4.6 03/09/2007 14:40:00 14.7 2 19.5 9.5 14.1 2.3 20.2 8.8 14.8 2.1 21.8 8.4 341 12 344 165 -4.3 0 -3.9 -4.6 03/09/2007 14:50:00 15.7 2.2 21.8 9.9 15.7 2.4 21.8 7.6 15.8 2.1 20.6 9.9 338 9 347 165 -4.4 0 -4.2 -4.6 03/09/2007 15:00:00 16.4 1.9 20.2 10.7 16.2 2.2 20.2 9.9 16.4 2.1 21 10.7 337 9 338 165 -4.2 0.1 -3.9 -4.4 03/09/2007 15:10:00 15.4 2.5 21 8.4 14.9 2.9 21 6.8 15.5 2.5 21.8 8.8 340 11 338 165 -3.6 0.2 -3.3 -4.2 03/09/2007 15:20:00 15.1 1.9 20.2 10.3 15 2.3 19.9 8.8 15.2 1.9 19.9 9.9 343 8 325 165 -3.6 0.1 -3.3 -3.9 03/09/2007 15:30:00 13.8 2.2 18.3 6.5 13.5 2.3 18.3 6.5 13.6 2.4 19.1 6.8 335 10 342 165 -3.3 0 -3.3 -3.5 03/09/2007 15:40:00 13.4 2.2 18.7 8 13.2 2.1 18.3 8.4 12.2 2.2 17.2 6.1 328 9 331 165 -2.8 0.3 -2.6 -3.5 03/09/2007 15:50:00 11.2 1.8 15.3 7.2 10.8 2.2 15.3 4.6 10.8 1.9 15.6 6.5 336 12 337 165 -3 0.1 -2.6 -3.3 03/09/2007 16:00:00 12.4 2.7 18.3 7.2 11.8 3.1 18.3 5.7 12.2 2.5 17.9 7.2 337 13 336 165 -2.8 0.1 -2.6 -3 03/09/2007 16:10:00 12.7 2.2 17.9 7.6 12.5 2.1 17.2 7.6 12.2 2.3 17.6 7.2 325 9 311 165 -3.1 0 -2.8 -3.3 03/09/2007 16:20:00 11 1.8 14.9 5.3 10.9 1.9 14.9 5.3 10.8 1.8 15.3 5.3 330 12 334 165 -3.5 0.2 -3 -3.9 03/09/2007 16:30:00 10.7 2.1 15.6 6.1 10.6 2.1 15.6 5.7 10.1 2.1 14.9 4.9 332 12 340 165 -4.2 0.1 -3.9 -4.4 03/09/2007 16:40:00 12.5 2 16.8 7.2 12.3 2 16.8 6.8 12.1 1.9 16.4 7.2 330 9 332 165 -4.5 0.1 -4.2 -4.6 03/09/2007 16:50:00 13.6 1.8 17.6 8.4 13.5 1.9 17.2 7.2 13.1 1.9 17.6 8.8 334 9 332 165 -4.4 0.1 -4.2 -4.8 03/09/2007 17:00:00 11.3 1.6 16.4 7.2 11.1 1.7 15.6 7.2 11 1.4 15.6 6.8 336 10 354 165 -4 0 -3.7 -4.4 03/09/2007 17:10:00 13.2 2.3 17.6 7.6 12.8 2.6 17.2 5.3 12.9 2.4 17.6 8 337 12 333 165 -3.7 0.1 -3.5 -3.9 03/09/2007 17:20:00 11.5 2.2 19.5 5.3 10.5 2.7 19.5 4.9 11.5 2.2 18.7 6.5 345 13 347 165 -3.9 0 -3.5 -4.2 03/09/2007 17:30:00 12 1.7 18.3 7.6 10.7 2 16.8 6.1 12.1 1.9 17.6 8 348 12 353 165 -4 0.1 -3.9 -4.2 03/09/2007 17:40:00 12 1.8 16.8 8 11.1 2.2 17.6 5.7 12.3 2 17.2 8.4 344 13 349 165 -4.1 0 -3.9 -4.4 03/09/2007 17:50:00 9.8 1.7 14.9 5.3 9.1 2.1 14.5 4.9 9.7 1.9 14.5 5.3 342 16 338 165 -3.9 0 -3.5 -4.2 03/09/2007 18:00:00 10.8 1.5 15.3 7.6 10.3 1.9 15.3 5.7 10.6 1.7 15.6 6.5 340 13 316 165 -4 0 -3.7 -4.4 03/09/2007 18:10:00 11.4 1.5 16.1 8.4 11.2 1.7 15.3 6.1 11.4 1.4 15.6 8.4 337 11 326 165 -4.2 0.1 -3.7 -4.4 03/09/2007 18:20:00 11.4 1.6 15.3 7.6 11.1 1.8 15.3 6.5 11.4 1.6 15.6 6.5 339 11 317 165 -4.2 0 -3.9 -4.4 03/09/2007 18:30:00 11.8 1.6 15.6 8 11.5 1.8 16.1 5.3 11.5 1.5 14.9 8 340 9 340 165 -4.2 0 -3.9 -4.4 03/09/2007 18:40:00 11.5 1.8 16.8 6.8 11.3 1.9 16.4 6.1 11.2 1.8 15.6 6.5 333 9 333 165 -4.1 0 -3.9 -4.4 03/09/2007 18:50:00 10.7 1.5 15.6 7.2 10.6 1.6 15.3 7.2 10.6 1.5 15.6 7.6 330 12 332 165 -3.9 0 -3.5 -4.4 03/09/2007 19:00:00 10.4 1.5 14.5 6.1 10.1 1.8 14.1 5.7 10.7 1.5 14.5 6.1 342 11 337 165 -3.9 0 -3.7 -4.2 03/09/2007 19:10:00 11.8 1.7 16.4 8 11.1 1.7 16.4 6.8 11.9 1.8 18.3 7.6 343 12 346 165 -3.8 0 -3.5 -4.2 03/09/2007 19:20:00 13.7 1.9 18.3 8.8 12.8 2.7 18.7 5.7 13.9 1.8 19.1 8.8 346 9 343 165 -4 0.2 -3.5 -4.4 03/09/2007 19:30:00 13.4 1.8 19.1 9.1 12 2.6 19.5 6.1 13.7 1.9 19.5 9.1 349 8 349 165 -3.9 0.1 -3.5 -4.2 03/09/2007 19:40:00 12.4 1.6 16.4 8.4 12.3 1.7 17.6 7.6 12.6 1.7 16.4 8 340 9 345 165 -3.7 0.1 -3.5 -4.2 03/09/2007 19:50:00 11.7 2.1 18.3 6.1 10.8 2.5 18.7 5.3 11.8 2.2 18.7 7.2 345 12 345 165 -3.3 0 -3 -3.5 03/09/2007 20:00:00 10.8 1.7 15.3 6.5 9.1 2.1 14.9 3.8 11.1 1.8 15.6 7.2 351 9 353 165 -3.5 0 -3.3 -3.7 03/09/2007 20:10:00 12 1.5 16.1 8 11.7 1.9 16.8 7.2 12.2 1.6 17.6 8.8 344 7 342 165 -3.3 0.2 -3 -3.7 03/09/2007 20:20:00 13 1.7 17.2 9.1 12.8 1.8 17.6 8 13.2 1.7 17.6 9.9 342 8 332 165 -3.8 0.1 -3.5 -4.2 03/09/2007 20:30:00 13.4 1.5 17.2 9.1 11.7 2.6 17.2 6.5 13.8 1.5 17.6 9.5 351 9 347 165 -4 0.1 -3.7 -4.4 03/09/2007 20:40:00 13 1.4 17.2 9.5 11.5 2.7 17.6 5.7 13.3 1.6 17.6 9.9 349 8 356 165 -4.3 0 -3.9 -4.4 03/09/2007 20:50:00 13.2 1.6 17.6 9.5 13.3 1.8 18.7 8.8 13.4 1.6 17.6 9.1 342 7 344 165 -4.3 0 -4.2 -4.6 03/09/2007 21:00:00 11.6 1.6 14.9 8 10.8 2 15.6 6.1 12 1.7 16.4 8 346 9 342 165 -4.6 0.1 -4.4 -4.8 03/09/2007 21:10:00 10.8 1.5 14.9 6.8 9.7 2 14.9 4.6 11.1 1.5 16.1 7.2 348 11 349 165 -4.7 0.1 -4.4 -5 03/09/2007 21:20:00 10.2 1.1 13.3 6.8 8.7 1.7 13.7 4.6 10.5 1.2 14.1 7.6 353 11 15 165 -4.7 0 -4.4 -4.8 03/09/2007 21:30:00 11.1 1.5 15.6 7.6 10 2.1 15.6 5.7 11.5 1.5 15.3 7.2 346 13 3 165 -4.6 0.2 -4.2 -5 03/09/2007 21:40:00 11.1 1.1 16.1 8.8 11.1 1.3 16.4 7.2 11.3 1.2 16.1 8.4 335 9 342 165 -4.5 0.2 -4.2 -4.8 03/09/2007 21:50:00 11.7 1.3 15.3 8.8 11.8 1.6 15.3 6.8 12 1.4 15.3 8.8 336 10 337 165 -4.7 0 -4.4 -5 03/09/2007 22:00:00 10.4 1.1 13.3 8 9.6 2 13 4.9 10.5 1.2 14.1 8.4 343 16 339 165 -4.6 0.1 -4.4 -5 03/09/2007 22:10:00 10.9 1.5 14.9 7.6 10.4 1.7 14.5 5.7 11.2 1.5 15.3 8 343 9 351 165 -4.6 0 -4.4 -4.8 03/09/2007 22:20:00 9.9 1.3 13.3 7.2 8.7 1.7 12.6 4.9 10.2 1.3 14.1 7.6 349 13 349 165 -4.5 0.1 -4.4 -4.8 03/09/2007 22:30:00 10.1 1.1 12.6 7.2 10 1.2 12.6 7.2 10.5 1.1 13.3 7.6 338 9 360 165 -4.7 0 -4.4 -4.8 03/09/2007 22:40:00 10.4 1.3 14.1 6.5 10 1.3 13 6.1 10.7 1.3 14.5 6.5 339 12 358 165 -4.6 0 -4.4 -4.8 03/09/2007 22:50:00 10.2 1.2 13 7.2 10.1 1.3 13 6.8 10.5 1.3 13.3 7.2 339 9 343 165 -4.6 0.1 -4.4 -4.6 03/09/2007 23:00:00 8.3 0.9 10.3 5.7 8.2 0.9 10.7 5.3 8.2 0.9 10.7 5.3 329 13 347 165 -4.7 0.1 -4.4 -5 03/09/2007 23:10:00 9.1 1.2 12.6 6.1 8.9 1.2 12.2 6.1 9 1.3 12.6 6.5 330 13 339 165 -4.8 0.1 -4.4 -5.3 03/09/2007 23:20:00 10.9 1.7 15.3 7.2 10.8 1.8 15.3 7.2 11.1 1.7 15.3 7.6 331 9 337 165 -5.1 0.1 -4.8 -5.3 03/09/2007 23:30:00 10.3 1.1 13.3 8 10.2 1.3 13 5.3 10.5 1.2 14.1 7.6 339 10 349 165 -4.8 0 -4.6 -5 03/09/2007 23:40:00 10.8 1.5 15.3 6.1 10.7 1.6 16.1 5.3 11.2 1.6 15.3 6.8 340 8 348 165 -4.8 0 -4.6 -5 03/09/2007 23:50:00 9.9 1.2 13 6.5 9.6 1.3 13.3 6.5 10.2 1.3 13.7 7.2 338 10 351 165 -4.9 0 -4.6 -5 03/10/2007 00:00:00 9.3 1.2 13 6.5 9.2 1.3 13 6.5 9.5 1.2 12.2 7.2 339 8 333 165 -4.9 0.1 -4.6 -5.3 03/10/2007 00:10:00 10.5 0.9 13.3 8.8 10.3 1.1 13 6.8 10.8 1 13.3 8.4 342 8 336 165 -4.8 0 -4.6 -5 03/10/2007 00:20:00 10.8 1.3 15.3 7.2 10.8 1.6 15.3 6.1 11.3 1.3 14.9 7.2 343 6 340 165 -5.1 0.1 -4.8 -5.5 03/10/2007 00:30:00 9.9 1 13.3 7.6 10 1.2 13.3 5.3 10.5 1 13.7 7.6 341 7 332 165 -4.8 0 -4.6 -5 03/10/2007 00:40:00 11.1 1.3 14.5 7.6 10.9 1.7 14.9 5.7 11.5 1.2 14.5 8.8 342 8 339 165 -5 0.1 -4.6 -5.3 03/10/2007 00:50:00 11.1 1.1 13.7 8 10.7 1.5 13.7 6.1 11.6 1.2 15.6 8.8 343 10 344 165 -4.9 0 -4.6 -5.3 03/10/2007 01:00:00 10.3 1.3 14.9 6.8 10 1.6 14.9 5.7 10.6 1.3 14.1 6.8 338 11 349 165 -4.9 0.1 -4.6 -5.3 03/10/2007 01:10:00 8.6 0.9 11.5 6.5 8.4 0.9 11.1 6.5 8.3 1.1 11.1 5.3 319 10 319 165 -4.9 0.1 -4.6 -5.3 03/10/2007 01:20:00 8.2 1.1 11.1 5.3 8.1 1.1 11.1 5.3 8.2 1 11.5 5.3 330 11 331 165 -4.7 0.2 -4.2 -5.3 03/10/2007 01:30:00 9.1 1.3 13 5.7 8.7 1.7 13 4.2 9.2 1.5 12.2 5.7 339 14 326 165 -4.5 0 -4.4 -4.6 03/10/2007 01:40:00 9.7 0.9 11.8 7.2 7.9 1.8 12.6 4.6 10.1 0.9 12.2 8 352 8 341 165 -4.3 0.1 -3.9 -4.8 03/10/2007 01:50:00 9.9 0.8 11.8 8 8.5 1.9 13 4.9 10.3 1 12.6 6.8 351 7 344 165 -3.8 0.1 -3.5 -4.4 03/10/2007 02:00:00 11.1 1.1 14.9 8.8 11.2 1.5 15.6 5.7 11.4 1.2 15.3 8.8 343 7 347 165 -3.9 0 -3.5 -4.2 03/10/2007 02:10:00 10.6 1.3 14.1 7.6 10.5 1.5 14.9 6.1 10.8 1.3 14.9 8 339 8 349 165 -4 0.1 -3.9 -4.4 03/10/2007 02:20:00 8.1 0.8 10.3 6.1 8 0.9 9.9 5.3 8.3 0.8 10.3 6.1 332 10 324 165 -4.2 0 -3.9 -4.6 03/10/2007 02:30:00 8.7 0.9 11.8 6.1 8.6 0.9 11.5 6.5 8.5 1.1 11.8 5.7 320 12 323 165 -4.5 0.1 -4.2 -4.6 03/10/2007 02:40:00 10.1 1.5 14.1 5.7 10.2 1.7 14.5 6.1 10.1 1.5 14.1 6.1 337 10 345 165 -4.4 0.3 -3.7 -4.8 03/10/2007 02:50:00 10.8 1.2 13.3 8 10.7 1.5 13.7 5.7 11 1.4 14.1 6.8 339 9 335 165 -3.6 0.1 -3.3 -3.9 03/10/2007 03:00:00 9.8 1 13 7.6 9.8 1.2 13.3 6.1 10 1 13 7.6 337 7 338 165 -3.6 0 -3.5 -3.5 03/10/2007 03:10:00 9.6 1.2 12.6 6.8 9.4 1.3 13 6.5 9.9 1.4 13.7 6.8 341 8 356 165 -3.5 0.1 -3.3 -3.9 03/10/2007 03:20:00 9.7 1.4 13.7 6.8 9.7 1.5 13.7 6.5 9.9 1.5 13.7 7.2 336 9 333 165 -3.5 0 -3.3 -3.7 03/10/2007 03:30:00 11.5 1.7 15.6 7.2 11.5 1.9 16.1 4.9 11.6 1.7 15.6 7.2 341 8 346 165 -3.7 0.2 -3.3 -4.2 03/10/2007 03:40:00 10.8 1.7 16.8 7.2 10.8 1.7 16.4 6.5 10.9 1.7 17.9 7.2 335 11 344 165 -3.6 0 -3.3 -3.9 03/10/2007 03:50:00 9.9 1.5 13.3 6.5 9.8 1.5 13.3 6.1 9.9 1.5 13.3 5.3 330 8 334 165 -3.5 0 -3.3 -3.9 03/10/2007 04:00:00 9 1 12.2 6.5 8.8 1 12.6 6.1 8.8 1.2 12.6 5.7 324 12 334 165 -3.4 0 -3.3 -3.7 03/10/2007 04:10:00 8.6 1.5 12.2 4.9 8.5 1.5 11.8 4.6 8.4 1.5 11.8 4.6 322 11 315 165 -4.1 0.1 -3.5 -4.4 03/10/2007 04:20:00 8.2 1.4 11.5 4.9 8.1 1.4 11.8 5.3 8.2 1.6 13 5.3 330 12 324 165 -4 0.2 -3.5 -4.4 03/10/2007 04:30:00 10.1 1.1 13 7.2 9.8 1.7 13.3 4.9 10.4 1.2 13.3 8 343 8 334 165 -3.4 0.1 -3.3 -3.5 03/10/2007 04:40:00 7.1 1.7 10.7 3.8 6.7 1.7 11.1 2.6 7.2 1.7 11.1 3.4 338 15 342 165 -3.4 0 -3.3 -3.5 03/10/2007 04:50:00 5.8 1.2 8.4 3 5.6 1.2 8.4 3 5.6 1.1 8 3 328 15 344 165 -3.6 0.1 -3.3 -3.9 03/10/2007 05:00:00 7.4 1.7 12.2 4.2 7.1 1.7 11.8 3.4 7.3 1.7 11.8 4.2 331 17 353 165 -3.6 0.1 -3.3 -4.2 03/10/2007 05:10:00 6.9 1.5 11.8 3.8 6.8 1.5 11.8 3.4 6.3 1.5 11.5 3.4 316 12 339 165 -3.7 0.1 -3.3 -4.2 03/10/2007 05:20:00 8.6 1.4 11.5 5.3 8.3 1.5 11.5 4.9 8.3 1.5 12.2 5.3 330 15 324 165 -3.7 0.2 -3.3 -3.9 03/10/2007 05:30:00 10.2 1.8 14.5 6.1 10 1.9 14.9 6.1 9.9 1.8 14.5 6.1 334 10 335 165 -3.5 0.1 -3.3 -3.5 03/10/2007 05:40:00 10.6 1.2 13.3 7.6 10.5 1.2 13.3 7.6 10.4 1.3 14.1 7.2 325 8 332 165 -3.6 0.1 -3.3 -3.9 03/10/2007 05:50:00 9.9 1 13 7.6 9.8 1 13 7.6 8.9 1.3 12.6 6.1 313 9 331 165 -4.5 0.3 -3.9 -5 03/10/2007 06:00:00 9.8 1.3 13.3 5.7 9.7 1.3 13.3 5.7 8.5 1.1 13 5.7 305 11 328 165 -4.9 0 -4.6 -5.3 03/10/2007 06:10:00 7.6 1.2 10.3 4.9 7.5 1.2 10.7 4.9 7.1 1.2 10.3 3.8 313 9 307 165 -5.3 0 -5 -5.5 03/10/2007 06:20:00 8.3 1.6 12.2 4.2 8.2 1.6 12.2 4.2 7.2 1.3 10.7 2.6 307 14 285 165 -5.2 0 -5 -5.3 03/10/2007 06:30:00 7.6 1.4 11.8 4.2 7.6 1.4 11.5 4.6 6.5 1.2 11.1 3.4 308 12 312 165 -4.9 0.1 -4.6 -5.3 03/10/2007 06:40:00 7.2 1.2 10.3 3.8 7.1 1.2 9.9 3.8 6.4 1.2 9.9 3.4 315 12 319 165 -4.6 0 -4.4 -4.8 03/10/2007 06:50:00 10.4 1.4 14.1 7.2 10.2 1.3 13.3 6.8 9.1 1.5 13 5.3 315 9 307 165 -4.8 0 -4.4 -5 03/10/2007 07:00:00 10 1.6 14.1 4.9 9.9 1.6 14.5 5.3 8.3 1.6 12.2 3.8 309 13 301 165 -5 0 -4.6 -5.3 03/10/2007 07:10:00 11 1.8 16.1 4.2 11 1.8 15.3 3.8 9 2.2 13.7 3 308 11 288 165 -5.2 0 -5 -5.3 03/10/2007 07:20:00 15.3 1.7 19.5 11.1 15.1 1.7 19.5 11.1 13.6 2.2 19.1 7.6 310 9 317 165 -5 0 -4.8 -5.3 03/10/2007 07:30:00 15.5 1.7 20.2 11.1 15.3 1.6 19.5 10.3 14.8 1.7 19.1 9.9 319 10 325 165 -4.8 0.2 -4.4 -5 03/10/2007 07:40:00 15.9 2 20.2 9.9 15.8 1.9 20.6 9.9 15.1 1.9 19.9 10.3 321 12 305 165 -4.5 0.2 -3.9 -4.8 03/10/2007 07:50:00 18.8 2.1 26.3 13 18.6 2.1 25.6 13.3 17.6 2 25.2 11.8 311 8 301 165 -4.8 0.1 -4.4 -5 03/10/2007 08:00:00 18.7 2.1 24 12.2 18.6 2.2 24 11.8 17.5 2.3 24 11.8 313 8 302 165 -4.7 0.1 -4.4 -5 03/10/2007 08:10:00 18.4 1.9 24.4 12.6 18.3 1.9 24 13 17.1 1.9 24 11.1 311 9 309 165 -4.4 0.3 -3.9 -5 03/10/2007 08:20:00 17.5 2.1 24 10.7 17.4 2.1 24 11.1 15.5 2.4 22.1 10.3 309 10 297 165 -3.8 0.2 -3.5 -4.4 03/10/2007 08:30:00 17.8 2.5 24 10.7 17.6 2.5 23.7 10.3 16.6 2.5 23.7 11.5 312 10 318 165 -3.7 0.1 -3.3 -4.2 03/10/2007 08:40:00 17.2 2.7 24.8 10.7 16.9 2.8 24.4 9.9 16.4 3.1 26.3 8.8 318 15 352 165 -3.2 0.1 -2.8 -3.7 03/10/2007 08:50:00 20.2 2.9 27.1 9.9 20 3.1 27.5 9.9 20 3.3 27.9 10.3 328 11 339 165 -2.9 0.1 -2.6 -3.3 03/10/2007 09:00:00 20.3 2.9 26.8 11.5 20.1 2.9 26.3 11.5 20.1 3.2 26.8 10.7 333 10 341 165 -2.6 0 -2.4 -2.8 03/10/2007 09:10:00 18.3 3.3 26.8 9.9 18.1 3.3 26.3 9.9 18 3.6 27.1 10.7 331 12 319 165 -2.9 0.2 -2.6 -3.3 03/10/2007 09:20:00 16.2 1.9 21 11.5 16 2 21 11.5 15.6 2.1 21.4 9.5 330 9 318 165 -3.5 0.1 -3.3 -3.5 03/10/2007 09:30:00 17.6 2.4 23.3 11.8 17.5 2.4 23.3 11.5 16.8 2.4 22.9 11.1 318 12 310 165 -3.8 0 -3.5 -3.9 03/10/2007 09:40:00 17.7 2.3 24.4 13 17.6 2.3 24.4 13.3 17.6 2.4 24.4 11.8 329 10 325 165 -3.8 0.1 -3.5 -4.2 03/10/2007 09:50:00 17.4 2.2 23.3 11.8 17.2 2.3 23.7 11.1 16.9 2.3 22.9 11.8 325 13 344 165 -3.5 0 -3.3 -3.9 03/10/2007 10:00:00 17.2 1.7 21.8 12.6 17.1 1.8 22.1 12.6 16.4 1.7 21.4 12.2 325 12 282 165 -3.7 0.1 -3.3 -3.9 03/10/2007 10:10:00 17.3 1.6 20.6 11.8 17.1 1.7 21 11.5 17 1.8 21.4 11.8 324 9 321 165 -3.8 0 -3.5 -4.2 03/10/2007 10:20:00 18.1 2.2 24.8 12.2 18 2.3 24.4 11.8 18.2 2.2 24.8 11.8 326 12 317 165 -3.7 0.2 -3.3 -4.2 03/10/2007 10:30:00 16.9 2.3 24 11.5 16.8 2.2 23.7 11.8 16.9 2.1 23.3 13 330 9 328 165 -3.4 0 -3.3 -3.5 03/10/2007 10:40:00 17.2 1.9 23.7 13.3 17 1.9 23.7 13.3 16.7 2 22.9 12.2 327 8 339 165 -3.6 0 -3.3 -3.9 03/10/2007 10:50:00 17.5 2.2 23.3 13 17.4 2.2 23.3 11.5 17.3 2.3 23.3 12.6 333 8 341 165 -3.2 0.2 -2.8 -3.5 03/10/2007 11:00:00 16 2.4 23.3 10.7 15.9 2.5 23.7 9.5 15.8 2.4 23.3 9.9 331 9 339 165 -2.9 0.2 -2.4 -3.3 03/10/2007 11:10:00 14.4 2.4 20.2 8.8 14.3 2.4 20.2 9.1 13.9 2.3 19.5 8 334 11 328 165 -2.3 0.2 -1.9 -2.6 03/10/2007 11:20:00 14.2 1.9 18.7 9.1 14 2 18.3 9.5 13.9 1.9 18.7 8 332 12 355 165 -2.7 0.3 -2.1 -3 03/10/2007 11:30:00 13.5 1.6 17.9 8.8 13.3 1.6 16.4 8.4 13.2 1.7 16.8 8.4 337 9 355 165 -2.8 0.2 -2.1 -3 03/10/2007 11:40:00 13.3 2 17.6 8.8 12.8 2 17.9 8.4 13.1 2.1 17.9 7.6 338 11 346 165 -2.2 0 -1.9 -2.6 03/10/2007 11:50:00 12.9 2.6 19.1 6.5 12.5 2.6 19.9 6.5 12.8 2.7 18.7 5.7 338 11 340 165 -2.1 0.1 -1.7 -2.4 03/10/2007 12:00:00 12.1 1.9 17.9 7.2 11.9 2.2 18.3 6.8 11.2 2 16.4 6.1 339 10 341 165 -1.6 0 -1.4 -2.1 03/10/2007 12:10:00 10.7 2.4 17.2 5.7 10.1 2.2 17.6 5.3 10.4 2.2 16.1 6.5 343 11 350 165 -1.7 0 -1.4 -1.9 03/10/2007 12:20:00 10.3 1.7 14.1 5.7 10.2 1.8 14.1 5.3 9.9 1.8 14.1 4.9 337 9 345 165 -1.4 0 -1.2 -1.7 03/10/2007 12:30:00 12.9 2.1 17.6 7.2 12.5 2.4 18.3 5.7 12.4 2.1 16.8 4.9 344 8 344 165 -1.6 0 -1.4 -1.9 03/10/2007 12:40:00 12.8 2.2 18.3 7.2 12.1 2.4 18.3 4.6 12.4 2.1 18.7 6.8 347 8 344 165 -0.8 0.4 -0.1 -1.4 03/10/2007 12:50:00 11.9 1.7 15.6 8 11.5 1.8 16.1 7.2 11.5 1.7 15.6 7.6 344 7 345 165 -0.6 0 -0.1 -0.8 03/10/2007 13:00:00 12.7 1.7 18.7 8.4 12.3 1.8 17.6 7.6 12.2 1.7 17.6 8 344 9 351 165 -0.6 0.1 -0.3 -0.8 03/10/2007 13:10:00 14.3 1.6 17.9 9.9 12.4 2.1 17.9 6.8 13.6 1.9 19.1 9.1 350 8 352 165 0.4 0.2 0.9 -0.5 03/10/2007 13:20:00 13.3 1.6 18.3 9.1 10.6 2.2 16.1 5.7 12.9 1.7 17.6 8.8 355 8 350 165 0.9 0.2 1.6 0.7 03/10/2007 13:30:00 12.7 1.4 16.8 9.5 8.9 1.7 13.3 5.7 12.4 1.5 16.4 8.8 1 7 357 165 1.8 0.3 2.6 0.9 03/10/2007 13:40:00 12.7 1.6 16.4 8.4 10 2 14.9 6.1 12.4 1.7 16.8 7.2 355 7 356 165 1.8 0.4 2.6 0.9 03/10/2007 13:50:00 12.8 1.8 17.6 7.6 10.7 2.5 17.9 5.3 12.5 1.7 16.8 7.6 359 12 348 165 1.7 0.5 2.6 0.9 03/10/2007 14:00:00 11 1.9 16.8 6.8 9.3 2.4 16.8 4.6 10.6 2.1 17.6 5.7 358 13 15 165 1.2 0.4 1.8 0.7 03/10/2007 14:10:00 11.3 2.1 16.1 6.5 10 2.7 16.8 4.2 10.7 2.1 16.1 4.9 2 17 351 165 1.4 0.6 2.3 0.2 03/10/2007 14:20:00 12 1.7 16.8 6.8 10.4 1.7 16.1 5.3 11.6 1.7 16.8 6.1 351 12 4 165 -0.5 0.2 0.2 -0.8 03/10/2007 14:30:00 12.5 1.4 15.6 8.4 9.6 1.7 13.7 5.3 12.2 1.5 15.6 5.3 355 7 355 165 -0.1 0.5 1.1 -0.8 03/10/2007 14:40:00 13.4 1.7 18.3 8 11.1 2.4 16.1 6.1 13.2 1.7 18.3 8.8 355 9 11 165 1.1 0.2 1.6 0.2 03/10/2007 14:50:00 10.7 1.5 16.1 6.8 8.4 2.2 13.7 4.2 10.4 1.6 14.9 6.8 356 7 353 165 0.8 0.4 1.6 0.2 03/10/2007 15:00:00 9.3 1.6 13.3 4.9 8.6 2 13.7 4.2 9 1.7 13 4.2 349 7 356 165 2 0.3 2.6 1.4 03/10/2007 15:10:00 12.4 3.2 18.3 5.7 9.9 3.3 16.8 3.4 12 3.2 17.6 5.3 2 12 20 165 -0.2 0.9 1.6 -1.4 03/10/2007 15:20:00 12.6 1.7 16.4 8 9.3 2.3 16.4 4.9 12.3 1.7 16.4 7.6 357 9 5 165 -0.5 0.6 0.9 -1.4 03/10/2007 15:30:00 15 2.3 20.6 9.1 11.9 2.9 18.7 5.3 14.5 2.5 21 8.8 355 8 346 165 0.6 0.6 1.6 -0.3 03/10/2007 15:40:00 12 1.5 15.6 7.2 9 2.1 14.5 4.6 11.7 1.5 15.6 7.6 358 10 6 165 0.2 0.3 0.9 -0.3 03/10/2007 15:50:00 11.2 1.7 16.1 7.6 8.6 1.9 14.9 4.9 10.9 1.6 15.3 7.2 9 10 3 165 0.5 0.2 1.1 0.2 03/10/2007 16:00:00 12.1 1.3 15.6 8.8 8.7 1.5 13.7 5.3 12 1.5 15.3 8 6 8 8 165 -0.2 0.2 0.7 -0.5 03/10/2007 16:10:00 10.2 1.9 14.5 4.9 7.6 1.8 12.6 4.2 10.1 1.9 14.1 4.9 6 9 5 165 1.1 0.3 1.6 0.2 03/10/2007 16:20:00 9 1.5 12.6 5.3 6.9 1.7 11.1 3 8.7 1.5 11.8 4.9 357 8 9 165 0.5 0.6 1.6 -0.3 03/10/2007 16:30:00 11.5 1.5 14.5 6.5 9 1.9 14.1 5.3 11 1.7 14.5 5.3 357 9 18 165 -0.9 0.3 -0.1 -1.4 03/10/2007 16:40:00 11.1 1.7 15.3 7.2 8.6 2.5 15.6 4.6 10.8 1.7 14.9 7.2 355 8 339 165 -1.3 0 -1.2 -1.4 03/10/2007 16:50:00 10.9 1.7 14.5 6.8 9.5 2.2 14.9 3.8 10.6 1.7 15.3 7.2 349 9 339 165 -1.2 0 -1 -1.4 03/10/2007 17:00:00 11.2 1.5 17.6 8.8 8.9 2.3 16.8 4.9 11.2 1.5 16.8 8 353 7 352 165 -1 0 -0.8 -1.4 03/10/2007 17:10:00 11.3 1.7 14.9 7.2 9.7 2.5 15.3 4.9 10.9 1.7 15.6 6.5 350 8 356 165 -1.1 0 -0.8 -1.2 03/10/2007 17:20:00 8.8 2.1 13.7 4.2 8.4 1.9 13.3 4.6 8.6 2 13.7 4.9 336 12 350 165 -1.5 0 -1.2 -1.9 03/10/2007 17:30:00 10.8 1.8 15.6 7.2 9.7 1.9 16.1 4.9 10.5 1.7 16.8 7.2 343 13 358 165 -2 0.1 -1.7 -2.1 03/10/2007 17:40:00 13.4 1.2 16.4 10.3 12.2 1.8 16.1 6.8 13.1 1.5 17.2 9.5 348 7 358 165 -2.4 0.1 -2.1 -2.6 03/10/2007 17:50:00 14.1 1.4 18.3 10.3 12.7 2.1 17.9 7.2 13.8 1.3 17.9 9.9 349 7 354 165 -2.5 0 -2.6 -2.8 03/10/2007 18:00:00 13.6 1.6 18.3 9.9 12.4 2.1 16.8 6.1 13.2 1.6 16.8 8.8 350 7 348 165 -2.6 0 -2.6 -2.8 03/10/2007 18:10:00 13.2 1.4 16.8 9.9 11.5 2 15.3 6.1 12.9 1.6 16.4 9.1 346 10 350 165 -2.6 0 -2.6 -2.8 03/10/2007 18:20:00 14.3 2.2 21.8 10.3 11.8 2.1 17.9 7.2 14.1 2.3 21.4 9.5 353 9 352 165 -2.8 0 -2.6 -3 03/10/2007 18:30:00 14.3 1.9 19.1 9.9 13.4 2 18.3 8 13.9 2.2 19.9 9.5 345 9 356 165 -2.9 0 -2.6 -3 03/10/2007 18:40:00 13.8 1.7 19.1 9.9 13.1 2.1 19.5 7.6 13.3 1.7 18.3 9.1 344 9 337 165 -3 0 -2.8 -3.3 03/10/2007 18:50:00 11.9 1.3 15.3 8 11.3 1.6 15.6 5.7 11.1 1.3 14.1 7.6 345 9 346 165 -3.1 0 -2.8 -3.3 03/10/2007 19:00:00 10 1.7 13.7 5.7 9.7 1.7 13.7 4.6 9.4 1.7 14.1 5.7 339 9 336 165 -3.2 0 -3 -3.5 03/10/2007 19:10:00 9.2 1.7 14.1 5.3 8.6 1.7 13.7 3.8 9.1 1.9 14.9 4.6 341 15 319 165 -3.2 0 -3 -3.3 03/10/2007 19:20:00 7.8 1.3 11.1 4.2 7.5 1.3 11.1 3.8 7.4 1.3 10.7 4.2 328 15 330 165 -3.2 0 -3 -3.5 03/10/2007 19:30:00 8.3 1.3 12.2 5.7 8.1 1.5 13 4.6 8 1.3 12.6 5.3 340 10 348 165 -3.3 0 -3 -3.5 03/10/2007 19:40:00 8.9 1.1 11.5 6.8 8.8 1.3 11.8 5.7 8.6 1.2 11.5 5.7 342 6 332 165 -3.4 0 -3 -3.5 03/10/2007 19:50:00 10.1 1.4 13.3 6.5 9.9 1.5 13.3 6.5 9.8 1.5 13.3 6.1 334 7 330 165 -3.2 0 -3 -3.3 03/10/2007 20:00:00 10.7 1.2 13.3 7.6 10.6 1.2 13.3 7.2 10.5 1.2 13 6.5 339 8 338 165 -3.3 0 -3 -3.5 03/10/2007 20:10:00 11.6 1.3 14.9 8 11.5 1.5 14.9 6.8 11.5 1.3 14.1 7.6 338 8 326 165 -3.5 0 -3.3 -3.5 03/10/2007 20:20:00 14.4 1.5 17.9 10.3 14.3 1.5 17.9 9.9 14.1 1.5 18.3 10.3 338 6 331 165 -3.5 0 -3.3 -3.7 03/10/2007 20:30:00 14.1 1.4 17.2 9.1 14.1 1.5 16.8 9.5 14 1.5 17.9 9.1 337 6 340 165 -3.5 0 -3.3 -3.7 03/10/2007 20:40:00 13.4 1.5 17.2 9.1 13.3 1.5 17.2 9.1 13.1 1.7 17.6 8.8 336 7 344 165 -3.4 0 -3.3 -3.5 03/10/2007 20:50:00 12.5 1.4 16.1 8.4 12.5 1.5 15.6 8.8 12.2 1.7 16.4 8.4 338 8 339 165 -3.3 0 -3 -3.5 03/10/2007 21:00:00 10.6 1.5 14.5 5.7 10.5 1.7 14.5 5.7 10.5 1.6 14.5 6.1 343 8 339 165 -3.3 0 -3.3 -3.5 03/10/2007 21:10:00 7.5 1.3 11.8 4.2 7.3 1.4 11.8 3.4 6.4 1.5 11.1 0.7 328 16 312 165 -3.6 0.1 -3.3 -3.9 03/10/2007 21:20:00 8.2 1.7 13.3 4.9 8.1 1.7 13.7 4.2 7.3 1.8 13.7 3.4 327 16 344 165 -3.9 0 -3.7 -4.2 03/10/2007 21:30:00 10.1 1.7 14.1 5.7 9.8 1.7 14.1 5.3 9.3 1.7 13.3 5.7 339 11 355 165 -3.5 0 -3.3 -3.9 03/10/2007 21:40:00 9.9 1.4 13.3 5.7 9.6 1.4 13.3 6.1 9.2 1.4 12.6 5.7 337 12 343 165 -3.5 0 -3.3 -3.5 03/10/2007 21:50:00 9.7 1.2 13.3 6.5 9.5 1.2 13 6.1 8.8 1.3 11.8 4.6 329 12 356 165 -3.5 0.1 -3.3 -3.7 03/10/2007 22:00:00 10.2 1.2 13.3 6.5 9.9 1.2 13.3 6.1 9.4 1.3 12.2 6.5 333 13 347 165 -3.5 0 -3.3 -3.9 03/10/2007 22:10:00 12.8 1.6 16.1 7.6 12.6 1.6 15.6 6.8 11.1 1.7 15.6 6.5 310 6 308 165 -3.8 0.1 -3.3 -4.2 03/10/2007 22:20:00 14.2 1.5 17.2 8 14 1.4 16.8 8.4 12.8 1.5 16.4 7.6 312 8 321 165 -4 0 -3.7 -4.2 03/10/2007 22:30:00 14.8 1.7 18.3 9.5 14.5 1.7 17.9 9.5 13.2 1.5 18.3 9.1 314 9 304 165 -4.1 0 -3.9 -4.4 03/10/2007 22:40:00 16.5 1.5 19.9 11.8 16.3 1.5 19.9 11.5 14.4 1.5 19.9 10.3 310 7 313 165 -4.2 0 -3.9 -4.4 03/10/2007 22:50:00 17.6 1.4 20.6 13.3 17.3 1.4 20.2 13.7 16 1.3 18.7 11.5 310 6 297 165 -4.1 0 -3.9 -4.4 03/10/2007 23:00:00 17 1.4 20.6 13.7 16.8 1.3 20.2 13.3 15.2 1.7 20.2 11.5 309 6 315 165 -4 0 -3.9 -4.4 03/10/2007 23:10:00 17.7 1.7 22.6 13 17.4 1.7 22.1 12.2 15.8 2 20.6 10.3 310 7 300 165 -4.1 0 -3.9 -4.4 03/10/2007 23:20:00 16.4 1.5 20.2 11.5 16.1 1.5 19.9 11.5 15.4 1.6 19.5 11.5 316 8 310 165 -4.1 0 -3.7 -4.4 03/10/2007 23:30:00 16.2 1.3 20.2 13 15.8 1.3 19.9 13 15 1.5 18.3 10.7 314 6 310 165 -3.9 0 -3.5 -3.9 03/10/2007 23:40:00 15.5 1.6 20.6 9.9 15.3 1.6 20.2 9.9 14.6 1.6 19.9 9.9 319 10 315 165 -3.9 0.1 -3.7 -4.4 03/10/2007 23:50:00 17 2.6 22.9 11.8 16.8 2.6 22.6 11.5 16.7 2.8 22.6 11.1 332 12 339 165 -3.5 0 -3.3 -3.9 03/11/2007 00:00:00 17.2 1.7 22.1 13 16.9 1.9 23.3 11.5 16.8 2 22.6 12.6 326 12 338 165 -3.2 0 -3 -3.5 03/11/2007 00:10:00 17.5 1.3 21.8 14.5 17.2 1.3 21.8 14.1 16.7 1.4 20.6 12.2 314 6 312 165 -3.6 0 -3.3 -3.7 03/11/2007 00:20:00 16.5 1.5 22.1 12.2 16.3 1.5 21.8 12.2 14.5 1.9 21.4 9.5 310 6 316 165 -3.8 0 -3.5 -3.9 03/11/2007 00:30:00 13.8 1.7 19.1 8.8 13.7 1.7 19.1 8.4 11.8 1.8 17.2 7.6 307 10 303 165 -3.8 0 -3.5 -4.2 03/11/2007 00:40:00 13.2 2 18.3 8.4 13 2 18.3 8.4 12 1.8 17.9 8 318 13 346 165 -3.7 0.1 -3.5 -4.2 03/11/2007 00:50:00 14.8 1.8 19.9 10.3 14.5 1.7 19.5 10.3 12.7 1.7 16.8 8.4 308 9 323 165 -3.8 0 -3.5 -3.9 03/11/2007 01:00:00 14.7 1.7 20.2 9.5 14.6 1.7 19.9 9.1 12.4 2.1 18.7 7.6 306 9 310 165 -3.8 0.1 -3.5 -4.2 03/11/2007 01:10:00 13.8 1.7 17.6 9.1 13.7 1.7 17.6 8.8 11.8 1.9 16.4 7.2 310 9 302 165 -3.7 0.1 -3.5 -3.9 03/11/2007 01:20:00 13.2 1.9 18.3 7.2 13.1 1.8 19.1 7.2 11.3 2.1 16.8 6.1 307 9 303 165 -3.7 0 -3.5 -3.9 03/11/2007 01:30:00 14.8 1.9 20.2 9.9 14.6 1.9 20.2 9.5 11.9 1.6 16.4 8 303 10 295 165 -3.8 0 -3.5 -3.9 03/11/2007 01:40:00 15.7 2.2 20.2 10.3 15.5 2.1 20.2 9.9 12.5 1.9 18.3 8.4 301 8 300 165 -4 0.1 -3.7 -4.4 03/11/2007 01:50:00 16.3 1.7 21.4 10.7 16 1.7 21 10.7 12.6 1.7 18.7 8.8 300 8 295 165 -4 0 -3.7 -4.6 03/11/2007 02:00:00 16.2 1.7 19.5 10.3 15.9 1.6 19.1 10.3 12.4 1.5 16.8 8 300 9 295 165 -3.9 0 -3.7 -4.2 03/11/2007 02:10:00 13.9 2.1 18.7 9.1 13.7 2.1 18.3 9.1 10.8 1.8 17.6 6.8 298 9 308 165 -3.8 0.1 -3.5 -4.2 03/11/2007 02:20:00 12.6 2.1 17.6 6.1 12.5 2.1 17.9 6.1 10 1.9 16.4 4.9 296 11 305 165 -4.1 0 -3.9 -4.4 03/11/2007 02:30:00 10.5 2.1 16.1 6.5 10.5 2.1 16.1 6.5 9.2 2.2 15.6 4.6 288 11 288 165 -4 0.2 -3.5 -4.4 03/11/2007 02:40:00 11.4 2.1 16.1 6.5 11.4 2.1 15.3 6.5 9.7 1.8 15.3 5.7 288 10 292 165 -4.2 0 -3.9 -4.4 03/11/2007 02:50:00 11.8 1.5 15.3 8.4 11.8 1.5 15.6 8.8 10.7 1.6 15.6 6.8 286 7 285 165 -4.3 0 -4.2 -4.4 03/11/2007 03:00:00 11.7 1.5 14.9 8.4 11.7 1.5 14.9 8.4 9.9 1.4 13.3 6.8 289 7 297 165 -4.4 0 -4.2 -4.6 03/11/2007 03:10:00 13.1 1.1 16.4 9.5 13.1 1.2 16.4 9.5 9.4 1.4 13.7 6.8 296 6 296 165 -4.4 0 -4.2 -4.6 03/11/2007 03:20:00 13.7 1 16.1 10.7 13.6 1 16.1 10.7 10.4 1.4 13.7 7.6 303 5 304 165 -4.4 0 -4.4 -4.6 03/11/2007 03:30:00 12.7 0.6 14.1 9.9 12.6 0.6 14.5 10.3 10.7 1.3 13.3 7.2 307 5 310 165 -4.6 0.1 -4.4 -4.8 03/11/2007 03:40:00 12.2 0.7 13.7 9.5 12.1 0.7 14.1 9.5 10.7 1 13.3 8 308 4 304 165 -4.8 0 -4.6 -5 03/11/2007 03:50:00 13 0.6 14.1 10.7 12.8 0.6 14.1 10.7 12 0.9 13.7 9.5 311 3 310 165 -4.8 0 -4.6 -5 03/11/2007 04:00:00 12.7 0.7 14.1 10.3 12.6 0.7 14.1 10.3 11 0.9 13 8.4 308 4 306 165 -4.8 0 -4.6 -5 03/11/2007 04:10:00 12.2 0.9 13.7 8.4 12.1 1 13.7 8.4 10.1 1.3 12.6 6.8 306 5 298 165 -4.7 0 -4.4 -5 03/11/2007 04:20:00 12.4 0.8 14.1 9.1 12.2 0.8 13.7 9.1 10.9 1 13.3 8.4 310 4 307 165 -4.6 0.1 -4.4 -4.6 03/11/2007 04:30:00 8.5 1.6 13.3 4.9 8.4 1.6 13.3 4.9 7.7 1.7 12.6 3.8 313 13 309 165 -4.5 0.2 -4.2 -4.8 03/11/2007 04:40:00 3.2 2.1 8 0.4 3.2 2.1 8 0.4 3.1 1.7 7.6 0.4 313 51 320 165 -4.6 0 -4.4 -4.8 03/11/2007 04:50:00 8.4 1 11.1 4.9 8.5 1 11.1 4.9 8 1.1 10.7 4.9 285 7 291 165 -4.8 0 -4.6 -5 03/11/2007 05:00:00 8.4 1 10.3 5.7 8.5 1 10.3 5.7 7 1 9.9 4.6 298 7 303 165 -4.9 0 -4.6 -5 03/11/2007 05:10:00 7.4 0.7 9.1 5.3 7.4 0.7 9.1 4.9 6.3 1 9.1 4.2 296 6 295 165 -4.7 0 -4.6 -4.8 03/11/2007 05:20:00 6.8 0.6 8.4 4.9 6.8 0.6 8 4.9 6 1 9.1 3.8 296 7 284 165 -4.3 0.2 -3.9 -5 03/11/2007 05:30:00 8.2 1 10.3 6.1 8.2 1 10.7 6.1 7 1.3 10.7 4.6 294 5 287 165 -4.4 0.1 -3.9 -4.6 03/11/2007 05:40:00 10 0.5 11.5 8.8 10.1 0.5 11.5 8.8 8.8 0.9 11.1 6.1 292 3 293 165 -5.3 0.2 -4.6 -5.7 03/11/2007 05:50:00 9.3 0.7 11.1 7.6 9.3 0.7 11.1 7.6 8 0.9 9.9 5.7 291 6 298 165 -5.6 0.1 -5.5 -5.9 03/11/2007 06:00:00 8.9 0.5 10.3 7.2 8.9 0.5 10.3 6.8 7.4 1.3 10.7 5.3 297 7 287 165 -5.9 0 -5.7 -6.1 03/11/2007 06:10:00 8.8 0.6 10.3 7.2 8.9 0.7 10.7 6.8 7.5 1.1 9.9 4.9 293 5 292 165 -6 0 -5.7 -6.1 03/11/2007 06:20:00 7.4 0.6 9.1 5.7 7.4 0.6 9.1 5.7 5.9 1 9.1 4.2 296 6 294 165 -6.1 0 -5.9 -6.1 03/11/2007 06:30:00 7.2 1 9.9 4.6 7.2 1.1 9.9 4.6 5.9 1.2 9.1 3.8 293 6 300 165 -6.2 0 -6.1 -6.4 03/11/2007 06:40:00 7.3 0.8 9.5 5.7 7.4 0.8 9.5 5.3 6.6 0.9 8.4 4.2 287 7 290 165 -6.2 0 -6.1 -6.4 03/11/2007 06:50:00 6.6 0.8 8.4 4.6 6.6 0.8 8.8 4.6 5.4 0.8 7.2 3.4 299 8 288 165 -6 0.2 -5.7 -6.4 03/11/2007 07:00:00 5.5 0.9 7.6 3.8 5.5 0.9 7.6 3.8 4.8 1 7.6 2.6 306 7 309 165 -5.6 0 -5.5 -5.9 03/11/2007 07:10:00 4.6 0.5 5.7 3 4.6 0.5 5.7 3.4 3.9 0.6 5.7 2.6 294 7 302 165 -5.3 0.1 -5 -5.7 03/11/2007 07:20:00 3.7 0.9 6.1 1.5 3.8 0.9 6.1 1.5 3.7 0.7 5.7 2.3 284 10 287 165 -5.3 0 -5 -5.5 03/11/2007 07:30:00 4 0.5 5.3 2.6 4 0.6 5.3 2.6 4.2 0.7 5.3 1.9 282 6 281 165 -5.3 0 -5 -5.5 03/11/2007 07:40:00 5.6 0.5 6.8 4.2 5.6 0.5 6.5 4.2 5.3 0.6 6.8 3.4 289 3 291 165 -5.4 0 -5.3 -5.5 03/11/2007 07:50:00 5.8 0.6 7.2 4.6 5.9 0.6 7.2 4.2 5.7 0.8 7.6 3.4 287 5 273 165 -5.3 0.1 -5 -5.7 03/11/2007 08:00:00 5.8 0.6 7.6 4.2 5.7 0.6 7.6 4.2 4.8 0.7 6.5 3.4 296 6 296 165 -5.2 0 -5 -5.5 03/11/2007 08:10:00 6.5 0.5 7.6 4.9 6.5 0.5 7.6 4.6 5.8 0.9 8 3.4 294 6 292 165 -5.4 0 -5.3 -5.7 03/11/2007 08:20:00 7.3 0.7 8.8 4.9 7.3 0.7 8.8 4.6 5.9 0.8 8.4 3.8 295 7 294 165 -5.7 0 -5.5 -5.7 03/11/2007 08:30:00 7.4 0.7 9.1 5.3 7.4 0.7 8.8 4.9 6.1 1 9.1 3.8 294 5 280 165 -6 0 -5.7 -6.1 03/11/2007 08:40:00 7.5 0.7 9.5 5.7 7.5 0.7 9.1 5.7 6.3 0.9 9.1 4.2 294 7 295 165 -6 0 -5.9 -6.4 03/11/2007 08:50:00 7 0.7 8.8 5.3 7 0.8 8.8 4.9 5.8 1 8.4 3.8 296 7 288 165 -6.1 0 -5.7 -6.4 03/11/2007 09:00:00 6.6 0.8 8.8 4.6 6.5 0.8 8.8 4.6 5.3 0.7 7.2 3.4 301 6 302 165 -5.8 0.1 -5.5 -6.1 03/11/2007 09:10:00 7.9 0.8 9.9 5.7 7.9 0.8 9.9 5.7 6.4 0.9 9.9 4.2 298 7 302 165 -5.6 0 -5.5 -5.7 03/11/2007 09:20:00 6.7 0.9 9.1 4.2 6.7 1 9.1 4.6 5.9 0.9 8.4 3.4 298 9 287 165 -5.7 0 -5.5 -5.7 03/11/2007 09:30:00 8.9 1 11.5 6.1 9 1.1 11.5 5.7 7.6 1.3 10.7 4.6 296 6 300 165 -6 0.1 -5.5 -6.4 03/11/2007 09:40:00 10 1 13 7.2 10 1.1 12.6 7.2 8.2 1.1 11.1 5.7 300 9 289 165 -6.4 0.1 -5.9 -6.6 03/11/2007 09:50:00 10.2 1.1 13.3 5.7 10.2 1.1 13 5.7 8.3 1.2 11.1 4.9 300 10 310 165 -6.5 0 -6.1 -6.8 03/11/2007 10:00:00 10 1 11.8 6.8 10.1 1 11.8 6.8 8.4 1.1 11.8 5.7 300 11 294 165 -6.4 0.2 -5.7 -6.8 03/11/2007 10:10:00 10.7 1.1 13.3 8 10.7 1.1 13.3 8.4 8.4 1.4 12.2 5.7 297 9 301 165 -6.2 0.2 -5.7 -6.6 03/11/2007 10:20:00 10.1 0.9 12.6 8 10.1 0.9 12.2 8 8.1 1 11.1 5.7 296 9 300 165 -6.5 0 -6.1 -6.6 03/11/2007 10:30:00 9.9 0.8 11.8 7.2 9.9 0.8 11.8 7.2 7.6 1 11.1 5.3 301 8 311 165 -6.4 0 -6.1 -6.6 03/11/2007 10:40:00 10.8 1 13 7.6 10.7 1 13 7.6 8.2 1 11.5 4.9 297 7 293 165 -6.5 0 -6.1 -6.6 03/11/2007 10:50:00 10.3 0.8 13 8.4 10.3 0.9 13 8.4 8 0.9 11.5 6.1 302 7 302 165 -6.4 0.1 -6.1 -6.8 03/11/2007 11:00:00 10.3 0.8 11.8 8 10.3 0.8 11.8 8 8.7 1.1 11.8 6.1 306 7 302 165 -6.2 0 -5.9 -6.6 03/11/2007 11:10:00 9.9 0.8 12.2 7.2 9.9 0.9 11.8 7.6 8.7 1.2 12.2 6.1 308 7 305 165 -6.1 0 -5.7 -6.1 03/11/2007 11:20:00 9.7 1.3 12.6 7.2 9.6 1.3 12.6 6.8 9.1 1 11.5 6.5 314 7 297 165 -5.8 0.2 -5.3 -6.1 03/11/2007 11:30:00 8.2 0.8 10.3 5.7 8.1 0.8 10.3 6.1 7.5 1 9.9 4.9 311 6 314 165 -5.4 0.2 -5 -5.7 03/11/2007 11:40:00 8.9 0.8 12.2 6.8 8.8 0.8 11.5 6.8 7.5 1 11.1 5.7 308 8 305 165 -5.6 0 -5.5 -5.9 03/11/2007 11:50:00 8 1.1 9.9 5.3 7.9 1.1 9.9 5.7 6.6 0.9 9.9 4.2 305 8 294 165 -5.6 0.1 -5 -5.9 03/11/2007 12:00:00 6.8 0.7 8.4 4.9 6.8 0.7 8.4 4.9 6.5 0.8 8.4 4.2 316 9 314 165 -4.8 0.2 -4.4 -5.3 03/11/2007 12:10:00 7.2 0.5 8.4 4.9 7.1 0.5 8.4 4.9 6.6 0.8 8 4.2 311 7 302 165 -4.6 0 -4.4 -4.8 03/11/2007 12:20:00 8.1 0.8 10.7 5.7 8.1 0.8 10.3 5.3 6.6 0.8 8.8 4.6 303 9 302 165 -5.2 0.3 -4.4 -5.5 03/11/2007 12:30:00 9.5 0.8 11.5 6.8 9.5 0.8 11.8 6.8 7.1 0.7 9.5 5.3 302 6 301 165 -5.7 0.2 -5.3 -6.1 03/11/2007 12:40:00 9 1 11.1 6.1 9 1 11.1 6.1 7.1 0.9 9.5 4.6 301 8 297 165 -6 0.1 -5.7 -6.4 03/11/2007 12:50:00 9.7 1 11.5 6.1 9.7 1 11.5 6.1 7.4 1 10.7 5.3 301 8 302 165 -5.6 0 -5.5 -5.9 03/11/2007 13:00:00 10.6 0.6 11.8 9.1 10.7 0.5 11.8 9.1 8.6 1 11.1 6.1 305 4 313 165 -5.9 0.1 -5.7 -6.1 03/11/2007 13:10:00 10.4 0.8 12.2 8 10.4 0.8 11.8 8 9.4 1 11.8 6.1 310 5 307 165 -5.4 0.2 -5 -5.7 03/11/2007 13:20:00 10 0.7 11.5 7.6 10 0.7 11.5 7.6 8.5 1 10.7 6.1 308 5 309 165 -5.7 0.1 -5.3 -5.9 03/11/2007 13:30:00 9.4 0.8 11.8 7.2 9.4 0.8 11.8 6.8 8.2 1.2 10.7 5.3 309 6 299 165 -5.1 0.1 -4.6 -5.5 03/11/2007 13:40:00 10.1 0.7 11.8 7.6 10.1 0.7 11.8 7.6 8 0.8 10.3 6.1 306 5 278 165 -5.2 0.1 -5 -5.5 03/11/2007 13:50:00 9.6 0.8 11.8 7.6 9.6 0.8 11.8 7.2 8.1 1.1 11.8 5.3 307 6 302 165 -5 0 -4.8 -5.3 03/11/2007 14:00:00 8.7 0.8 10.7 6.5 8.6 0.8 10.7 6.8 7.8 1 10.7 5.7 310 6 319 165 -4.7 0.3 -4.2 -5.3 03/11/2007 14:10:00 9.1 0.7 11.1 7.2 9 0.6 10.7 7.2 7.9 1.1 10.7 5.3 312 11 307 165 -4.4 0.2 -4.2 -4.6 03/11/2007 14:20:00 9.2 0.5 10.7 7.6 9.2 0.6 10.7 7.6 8.1 0.9 9.9 5.7 310 6 307 165 -4.8 0.1 -4.6 -5.3 03/11/2007 14:30:00 11.1 1 13.3 8.8 11 0.9 13.3 8.8 9.3 1.5 13.3 6.5 307 5 298 165 -5.3 0.1 -5 -5.7 03/11/2007 14:40:00 11.6 1 14.1 8.8 11.5 1 13.7 8.8 11.2 1.1 14.1 8.4 314 5 309 165 -5.4 0.1 -5 -5.7 03/11/2007 14:50:00 11.1 1.2 13.3 8.4 11 1.2 13.3 8 10.6 1.2 13 7.2 313 7 310 165 -5.2 0.1 -5 -5.5 03/11/2007 15:00:00 11.6 0.9 13.7 8.4 11.4 0.9 13.3 8.8 9.9 1.2 12.6 6.8 308 6 304 165 -5.3 0.1 -4.8 -5.7 03/11/2007 15:10:00 11.9 1 13.7 8.8 11.7 1 13.7 8.8 10.9 1.2 13.7 7.2 310 6 307 165 -5.4 0.1 -5.3 -5.7 03/11/2007 15:20:00 10.7 0.8 12.6 8 10.5 0.8 12.6 8.4 10 1 12.6 7.6 312 5 311 165 -5.2 0 -5 -5.5 03/11/2007 15:30:00 9 1.1 12.2 6.1 8.9 1.2 11.8 6.1 8.5 1.3 12.2 4.9 314 8 309 165 -4.9 0.3 -4.4 -5.5 03/11/2007 15:40:00 9.9 1 13 7.6 9.8 1 12.6 7.6 8.5 0.9 11.1 6.1 309 9 297 165 -4.7 0.3 -4.4 -5.5 03/11/2007 15:50:00 10.9 1.1 13.7 8 10.8 1.1 13.7 8.4 9.7 1.3 12.6 6.5 309 6 305 165 -5.6 0.2 -5.3 -5.7 03/11/2007 16:00:00 11.6 1 14.1 8 11.5 1 14.1 8 11 1.1 13.7 8 311 7 314 165 -5.8 0.1 -5.5 -6.1 03/11/2007 16:10:00 10 1.2 12.6 6.1 9.9 1.2 12.6 6.1 8.6 1.3 12.6 5.7 307 9 303 165 -5.5 0.2 -5 -5.7 03/11/2007 16:20:00 10.1 1.2 13.3 7.6 10 1.2 13.3 7.2 8.6 1.6 13.7 5.3 307 10 309 165 -5.6 0.2 -5.3 -6.1 03/11/2007 16:30:00 10.6 1.3 13.3 7.2 10.5 1.3 13.3 7.2 9.1 1.1 11.8 6.8 307 7 310 165 -5.8 0.1 -5.5 -6.1 03/11/2007 16:40:00 11.2 1.5 14.9 6.8 11.1 1.5 14.5 6.8 10.8 1.5 13.7 6.5 317 8 325 165 -6 0.1 -5.5 -6.4 03/11/2007 16:50:00 9 1.4 12.2 5.7 8.9 1.4 12.2 5.7 8.2 1 11.1 5.3 314 11 299 165 -5.4 0.2 -5 -5.9 03/11/2007 17:00:00 11.2 1.3 15.3 8.4 11.1 1.3 15.6 8.4 9.5 1.1 14.1 6.1 305 10 296 165 -6.2 0.1 -5.7 -6.6 03/11/2007 17:10:00 13.2 1 15.3 8.8 13 1 14.9 9.1 12.2 1.3 14.5 8.4 311 6 310 165 -6.5 0 -6.4 -6.8 03/11/2007 17:20:00 11.9 1 14.5 8.4 11.8 1 14.1 8.8 11.7 1.1 13.7 8.4 317 7 316 165 -6.5 0 -6.4 -6.8 03/11/2007 17:30:00 11.7 1 13.7 8 11.5 1 13.3 8 11.7 1 14.1 8.8 322 5 321 165 -6.5 0 -6.4 -6.8 03/11/2007 17:40:00 12.4 1.1 15.6 9.9 12.2 1.1 14.9 9.9 12.4 1.1 15.3 9.9 319 5 323 165 -6.7 0 -6.6 -6.8 03/11/2007 17:50:00 12.6 0.8 14.9 9.9 12.3 0.8 14.9 9.9 12.4 1 15.6 9.9 318 6 316 165 -6.9 0 -6.8 -7 03/11/2007 18:00:00 13.6 0.6 14.9 11.8 13.4 0.6 14.5 11.8 13.5 0.7 15.3 11.1 315 5 314 165 -7.2 0 -6.8 -7.4 03/11/2007 18:10:00 13.6 0.8 15.6 11.1 13.4 0.9 15.3 10.7 13.4 0.9 15.6 11.1 315 5 308 165 -7.4 0 -7.2 -7.4 03/11/2007 18:20:00 12.2 0.9 14.5 9.5 12 0.9 14.1 9.5 12.1 1 14.1 9.1 318 6 312 165 -7.5 0 -7.2 -7.6 03/11/2007 18:30:00 11.3 0.9 13.7 8.8 11.1 0.9 13.3 8.8 11.2 0.8 13 8.8 318 7 301 165 -7.8 0 -7.6 -8.1 03/11/2007 18:40:00 11.2 1.1 13.7 8.8 11 1.1 13.3 8.8 10.9 1.2 14.1 8 314 9 316 165 -8 0.1 -7.6 -8.1 03/11/2007 18:50:00 11.9 1 14.5 9.1 11.7 1 14.5 9.1 11.5 1.2 14.5 7.2 314 8 314 165 -8.2 0 -8.1 -8.3 03/11/2007 19:00:00 11.6 1 14.1 9.1 11.4 1 14.1 9.1 11.3 1.1 14.1 8.4 313 9 313 165 -8.3 0 -8.1 -8.5 03/11/2007 19:10:00 12.5 1.1 15.3 9.5 12.3 1.1 15.3 9.5 12.2 1 14.5 9.5 314 7 321 165 -8.3 0 -8.3 -8.5 03/11/2007 19:20:00 12.9 1 14.5 9.9 12.7 0.9 14.5 10.3 12.7 1.1 14.9 9.1 316 7 322 165 -8.4 0 -8.3 -8.5 03/11/2007 19:30:00 13.5 1 16.1 10.7 13.4 1 16.1 10.7 13.3 0.9 15.3 10.3 314 7 307 165 -8.4 0 -8.3 -8.5 03/11/2007 19:40:00 12.6 1.2 15.6 9.1 12.5 1.2 15.3 9.5 11.9 1 14.9 9.1 310 7 305 165 -8.5 0 -8.3 -8.7 03/11/2007 19:50:00 13.2 1.3 16.1 8.8 13.2 1.3 15.6 8.8 11.4 1.4 14.9 7.2 305 7 308 165 -8.5 0 -8.3 -8.7 03/11/2007 20:00:00 13.6 1.1 16.1 10.3 13.6 1.1 16.1 10.3 10.5 1.2 13.3 7.6 300 9 297 165 -8.5 0 -8.5 -8.7 03/11/2007 20:10:00 12.7 1.2 16.1 9.5 12.7 1.2 15.6 9.5 9.5 1.2 13.3 7.2 295 10 272 165 -8.5 0 -8.5 -8.7 03/11/2007 20:20:00 12.8 1.3 15.3 9.5 12.7 1.2 15.3 9.9 10.3 1.6 14.9 6.1 299 11 301 165 -8.6 0 -8.5 -8.9 03/11/2007 20:30:00 12.8 1.5 15.6 8.4 12.7 1.5 15.6 8.4 11.4 1.7 14.9 6.5 303 10 307 165 -8.7 0 -8.5 -8.9 03/11/2007 20:40:00 12.9 1.3 15.6 9.9 12.8 1.3 15.6 9.5 11.1 1.7 15.6 6.5 301 12 301 165 -8.7 0 -8.5 -8.9 03/11/2007 20:50:00 13.9 1.2 16.4 9.9 13.9 1.2 16.8 10.3 10.8 1.3 14.5 8.4 296 14 304 165 -8.7 0 -8.5 -8.9 03/11/2007 21:00:00 13.2 1.2 16.1 10.3 13.2 1.2 15.6 10.7 10.2 1.5 14.1 7.2 297 11 305 165 -8.5 0 -8.3 -8.7 03/11/2007 21:10:00 12.9 1.4 16.4 9.5 12.9 1.4 16.1 9.5 9.9 1.3 13.7 6.8 297 11 305 165 -8.6 0 -8.5 -8.7 03/11/2007 21:20:00 13 1.1 15.3 9.9 13 1.1 15.3 9.9 10.1 1.2 13.7 6.5 297 11 304 165 -8.6 0 -8.5 -8.7 03/11/2007 21:30:00 12.2 1.7 16.4 8.8 12.1 1.7 16.1 8.4 9.6 1.5 14.9 6.5 297 13 312 165 -8.5 0 -8.3 -8.7 03/11/2007 21:40:00 12.1 1 14.5 9.5 12 1 14.9 8.8 9.6 1.3 13.3 6.8 295 13 301 165 -8.5 0 -8.5 -8.9 03/11/2007 21:50:00 12.3 1.2 14.9 8.8 12.2 1.3 15.3 8.8 10.3 1.2 13.7 7.2 301 12 302 165 -8.6 0 -8.5 -8.7 03/11/2007 22:00:00 13.2 1 15.6 10.3 13 1 15.6 10.3 11.8 1.3 14.9 8 305 10 309 165 -8.5 0 -8.5 -8.7 03/11/2007 22:10:00 13 1 15.6 9.9 12.9 1 15.6 9.9 12.3 1.3 15.3 8.8 305 14 310 165 -8.5 0.1 -8.3 -8.7 03/11/2007 22:20:00 12.8 1 15.6 10.7 12.7 1 15.6 10.3 12.4 1.3 15.6 6.8 310 10 310 165 -8.6 0 -8.5 -8.7 03/11/2007 22:30:00 13.2 1.1 15.6 10.3 13.1 1.1 15.6 10.3 12.1 1.4 15.3 8.4 305 9 307 165 -8.7 0 -8.5 -8.9 03/11/2007 22:40:00 13.3 1.3 16.1 9.9 13.2 1.3 16.1 9.5 11 1.3 14.1 7.6 300 11 307 165 -8.7 0 -8.5 -8.9 03/11/2007 22:50:00 12.9 1.1 15.6 9.9 12.8 1.2 15.6 9.9 10.9 1.2 13.7 7.6 301 11 300 165 -8.8 0 -8.7 -8.9 03/11/2007 23:00:00 13 1 14.9 9.5 13 1 15.3 9.9 10.6 1.2 14.5 7.2 298 13 292 165 -8.9 0 -8.7 -9.1 03/11/2007 23:10:00 13.2 1 15.3 10.7 13.1 1 15.3 10.3 11.2 1.3 15.3 8 302 11 297 165 -9 0 -8.9 -9.1 03/11/2007 23:20:00 12.4 0.8 14.9 9.9 12.4 0.9 14.5 9.9 9.7 1.1 12.6 7.2 296 13 300 165 -9.1 0 -8.9 -9.1 03/11/2007 23:30:00 12.2 1 14.1 9.1 12.1 1 14.1 9.5 9.3 1 12.6 6.8 295 13 292 165 -9.1 0 -8.9 -9.3 03/11/2007 23:40:00 12.7 1.1 14.9 9.9 12.6 1.1 14.5 9.5 10.6 1.3 14.1 7.2 300 14 304 165 -9.1 0 -8.9 -9.3 03/11/2007 23:50:00 12.9 1.1 15.6 9.5 12.8 1.1 15.6 9.5 11.3 1.2 14.5 8 302 12 300 165 -9.1 0 -8.9 -9.3 03/12/2007 00:00:00 12.1 1.1 14.5 9.1 12 1.1 14.1 8.8 10.7 1.2 13.3 7.6 301 14 304 165 -9.1 0 -8.9 -9.3 03/12/2007 00:10:00 12.6 1.1 15.3 8.8 12.6 1.1 14.9 9.1 10.9 1.3 14.1 7.2 299 16 309 165 -9.1 0 -8.9 -9.1 03/12/2007 00:20:00 12.9 1 15.3 8.4 12.8 1 15.3 8.4 11.4 1.2 14.5 7.6 302 12 312 165 -9.1 0 -8.9 -9.3 03/12/2007 00:30:00 12.3 1 14.5 10.3 12.1 1 14.5 9.9 11.4 1.1 14.1 8 307 13 305 165 -9.1 0 -8.9 -9.3 03/12/2007 00:40:00 11.6 0.7 13.7 9.5 11.4 0.7 13.3 9.5 10.8 0.9 13 8.4 307 14 316 165 -9.2 0 -9.1 -9.3 03/12/2007 00:50:00 12.7 0.9 14.5 9.5 12.5 0.9 14.5 9.5 12.5 1.1 14.9 8.8 312 9 314 165 -9.2 0 -9.1 -9.5 03/12/2007 01:00:00 12.8 1 15.3 10.3 12.7 1 14.9 9.9 12.5 1.3 15.6 8.8 310 11 288 165 -9.3 0 -9.1 -9.3 03/12/2007 01:10:00 13.7 1 16.1 11.1 13.5 1 16.1 10.7 13 1.1 15.3 9.9 308 11 285 165 -9.3 0 -9.1 -9.5 03/12/2007 01:20:00 14 1 16.4 10.7 13.8 1 16.1 10.7 13.5 1.1 16.1 10.3 311 11 313 165 -9.3 0 -9.1 -9.5 03/12/2007 01:30:00 14.4 1.4 17.2 10.3 14.2 1.4 17.2 10.7 13.8 1.5 17.2 10.3 308 12 313 165 -9.4 0 -9.3 -9.7 03/12/2007 01:40:00 14.2 1.2 17.2 10.7 14 1.2 17.2 10.7 13.5 1.4 16.8 9.9 307 12 314 165 -9.5 0.1 -9.3 -9.7 03/12/2007 01:50:00 14.3 1.5 17.2 10.7 14.1 1.5 17.2 10.7 13.7 1.6 17.6 9.5 307 13 305 165 -9.7 0 -9.5 -9.7 03/12/2007 02:00:00 13.4 1.1 15.6 9.5 13.2 1.1 15.3 9.5 12.6 1.2 15.6 9.5 306 14 316 165 -9.8 0 -9.7 -10 03/12/2007 02:10:00 13.2 1.1 15.6 9.9 13 1.1 15.6 9.9 12.4 1.2 14.9 9.1 306 14 292 165 -9.9 0 -9.7 -10.2 03/12/2007 02:20:00 12.7 1 14.9 10.3 12.5 1 14.5 10.3 12.2 1 14.9 8.4 310 11 306 165 -9.9 0 -9.7 -10.2 03/12/2007 02:30:00 12.5 1.1 14.9 9.1 12.3 1.1 14.5 9.1 12.1 1.3 15.3 7.6 313 11 298 165 -9.7 0 -9.7 -10 03/12/2007 02:40:00 11.7 1.3 14.5 7.6 11.5 1.3 14.1 7.6 11.4 1.3 14.1 7.6 313 10 310 165 -9.7 0 -9.5 -9.7 03/12/2007 02:50:00 10.7 1.1 13.7 7.6 10.6 1.1 13.3 7.6 10.4 1.2 13.3 7.6 313 11 311 165 -9.6 0 -9.5 -10 03/12/2007 03:00:00 10.9 1.3 13.3 7.6 10.8 1.3 13 7.2 10.3 1.3 13.3 6.8 310 10 307 165 -9.6 0 -9.3 -9.7 03/12/2007 03:10:00 11.4 1.2 14.1 7.6 11.3 1.2 13.7 8 11.1 1.5 14.1 7.2 313 11 316 165 -9.7 0 -9.7 -9.7 03/12/2007 03:20:00 11 0.8 13.3 8.8 10.9 0.8 13.3 8.8 10.8 0.9 14.5 8.4 313 11 310 165 -9.8 0 -9.7 -10 03/12/2007 03:30:00 9.5 0.9 12.2 6.8 9.3 0.9 11.8 6.8 9.1 1.1 11.8 6.5 317 10 313 165 -10 0 -9.7 -10.2 03/12/2007 03:40:00 9.8 0.9 11.8 7.2 9.6 0.9 11.5 6.8 8.9 1 11.5 6.1 308 10 309 165 -10.1 0 -10 -10.2 03/12/2007 03:50:00 9.6 1.1 14.1 7.2 9.4 1.1 14.5 7.2 8.2 1.3 12.6 4.6 304 15 285 165 -10 0 -9.7 -10.2 03/12/2007 04:00:00 9.4 1.3 13.3 4.9 9.3 1.3 13.3 5.3 9.1 1.5 13.7 4.6 316 14 315 165 -9.5 0.1 -9.3 -10 03/12/2007 04:10:00 9.2 1.3 12.6 6.1 9.1 1.3 12.6 5.7 8.5 1.4 12.6 5.7 312 13 299 165 -9.6 0.1 -9.3 -9.7 03/12/2007 04:20:00 8.4 1.2 11.5 4.9 8.2 1.2 11.5 4.6 8 1.4 11.5 4.2 318 10 325 165 -9.8 0 -9.7 -10 03/12/2007 04:30:00 8.8 1.2 11.8 5.7 8.6 1.1 11.1 5.7 8.3 1.3 11.1 4.2 313 12 325 165 -9.9 0 -9.7 -10.2 03/12/2007 04:40:00 9.6 1.2 12.2 6.1 9.4 1.2 11.8 6.1 8.9 1.2 11.5 6.1 315 12 312 165 -9.8 0 -9.7 -10 03/12/2007 04:50:00 10.5 1.4 14.1 6.5 10.3 1.3 13.3 6.5 9.4 1.4 13 5.7 308 12 279 165 -9.9 0 -9.7 -10.2 03/12/2007 05:00:00 11.3 1.5 14.9 6.8 11.2 1.5 14.9 6.8 9.9 1.8 14.1 5.3 303 16 305 165 -10.1 0 -10 -10.2 03/12/2007 05:10:00 11.1 1.7 14.9 6.1 10.9 1.7 14.9 5.7 9.9 1.8 13.7 6.1 305 15 294 165 -10.2 0 -10 -10.4 03/12/2007 05:20:00 11 1.4 14.9 7.2 10.9 1.3 14.1 7.6 9.2 1.7 13.3 4.9 297 16 311 165 -10.3 0 -10.2 -10.6 03/12/2007 05:30:00 11.2 1.5 14.5 8 11.1 1.5 14.9 7.6 9.1 1.7 13 4.6 295 16 293 165 -10.3 0 -10.2 -10.4 03/12/2007 05:40:00 11.1 1.5 14.5 7.2 11 1.4 14.1 7.2 9.2 1.5 13.3 4.6 298 18 301 165 -10.4 0 -10.2 -10.6 03/12/2007 05:50:00 10.5 1.5 13.7 6.1 10.4 1.5 14.1 6.1 9.2 1.6 13.3 4.9 301 17 310 165 -10.5 0 -10.4 -10.8 03/12/2007 06:00:00 12 1.5 16.1 7.6 11.9 1.4 15.3 7.2 10.4 1.6 15.6 6.5 300 16 307 165 -10.6 0 -10.6 -10.8 03/12/2007 06:10:00 10 1.6 14.9 5.7 9.9 1.5 14.5 5.7 8.3 1.7 12.6 3 296 17 260 165 -10.5 0 -10.4 -10.8 03/12/2007 06:20:00 11.3 1.4 15.3 8 11.2 1.4 15.3 8 8.8 1.4 13 6.1 288 17 280 165 -10.2 0.2 -9.7 -10.6 03/12/2007 06:30:00 9.5 1.5 13.3 5.3 9.5 1.5 13 5.7 7.9 1.5 12.2 4.2 296 17 275 165 -9.7 0 -9.5 -10 03/12/2007 06:40:00 9.9 1.7 14.5 5.3 9.8 1.7 14.5 5.3 8.5 1.5 12.6 4.9 300 16 290 165 -9.5 0.1 -9.3 -10 03/12/2007 06:50:00 12.2 1.4 15.6 7.2 12.2 1.4 16.1 7.6 9 1.2 13.3 6.1 295 13 297 165 -9.8 0.3 -9.3 -10.2 03/12/2007 07:00:00 13 1.2 16.4 10.3 12.9 1.3 16.4 10.3 10.6 1.5 15.3 7.2 298 16 300 165 -10.2 0 -10 -10.4 03/12/2007 07:10:00 12.9 1.2 16.8 10.3 12.9 1.2 16.8 10.3 10.1 1.8 15.3 6.8 298 14 298 165 -10.5 0.2 -10.2 -11 03/12/2007 07:20:00 13.7 1.1 16.4 10.7 13.7 1.1 16.4 10.3 9.6 1.2 15.3 7.2 293 12 290 165 -10.7 0 -10.6 -11 03/12/2007 07:30:00 12.9 1.9 16.4 6.5 12.9 1.9 16.8 6.8 10.1 1.4 14.5 7.2 292 17 300 165 -10.5 0 -10.4 -10.8 03/12/2007 07:40:00 13.4 2 17.9 8.8 13.4 2 17.6 8.8 10.1 1.7 16.4 6.1 293 15 238 165 -10.4 0 -10.2 -10.6 03/12/2007 07:50:00 12.8 1.7 16.1 8.8 12.8 1.7 16.1 8.8 10.3 1.7 14.9 6.5 287 13 292 165 -10.5 0 -10.4 -10.8 03/12/2007 08:00:00 12.3 1.5 15.6 8 12.3 1.5 15.6 7.6 9.8 1.7 14.1 4.9 288 12 293 165 -10.5 0 -10.4 -10.8 03/12/2007 08:10:00 10.7 1.5 14.9 7.2 10.8 1.5 14.9 7.6 9.2 1.7 13.3 5.3 286 10 287 165 -10.5 0 -10.4 -10.8 03/12/2007 08:20:00 11.2 1.5 15.6 6.8 11.3 1.5 15.3 6.8 10.3 1.7 15.3 6.1 281 12 285 165 -10.4 0.1 -10.2 -10.8 03/12/2007 08:30:00 11.5 1.3 15.6 6.8 11.5 1.3 15.6 6.8 9.2 1.3 13 5.7 287 16 282 165 -10.3 0 -10.2 -10.4 03/12/2007 08:40:00 12.3 1.2 15.6 9.1 12.2 1.1 15.3 8.8 9.5 1.3 13.7 6.1 292 15 293 165 -10 0.1 -9.7 -10.4 03/12/2007 08:50:00 12.6 1.5 16.4 8.4 12.6 1.5 16.1 8.4 10 1.2 13 6.5 295 15 305 165 -9.7 0 -9.5 -10 03/12/2007 09:00:00 13.9 1.6 17.6 7.6 13.8 1.6 17.6 7.6 11.2 1.5 15.3 6.5 297 17 305 165 -9.6 0 -9.3 -9.7 03/12/2007 09:10:00 13.8 1.2 16.8 9.9 13.7 1.3 17.2 9.5 10.7 1.2 15.6 7.6 295 15 221 165 -9.4 0 -9.3 -9.7 03/12/2007 09:20:00 15.3 1.2 19.1 11.5 15.2 1.2 18.7 11.1 11.6 1.6 15.3 7.2 295 17 298 165 -9.2 0.1 -9.1 -9.7 03/12/2007 09:30:00 15.9 1.2 19.1 13 15.9 1.2 18.7 12.6 12.5 1.7 18.3 8.8 296 15 282 165 -9.1 0 -8.7 -9.3 03/12/2007 09:40:00 15.1 1.6 20.6 11.1 15 1.7 20.6 11.1 12.9 1.8 20.2 8.4 298 17 296 165 -8.9 0.1 -8.7 -9.1 03/12/2007 09:50:00 15.4 1.6 19.5 11.5 15.3 1.7 19.9 10.7 12.6 1.4 16.4 8.8 295 17 298 165 -8.7 0.3 -8.3 -9.3 03/12/2007 10:00:00 15.8 1.7 19.9 11.1 15.7 1.7 19.9 10.3 12.7 1.7 17.9 8.8 294 19 298 165 -8.7 0.1 -8.5 -8.9 03/12/2007 10:10:00 14.9 1.9 20.6 8.4 14.7 1.9 20.6 8.8 12.2 1.9 17.6 7.6 296 18 309 165 -8.3 0 -8.1 -8.5 03/12/2007 10:20:00 15.7 1.7 19.5 9.9 15.7 1.7 19.1 9.9 12.4 1.8 17.9 8 291 17 298 165 -8.3 0 -8.1 -8.5 03/12/2007 10:30:00 15.2 1.7 19.1 11.5 15.1 1.7 18.7 11.1 12.5 1.7 16.8 8 297 17 298 165 -8.3 0 -8.1 -8.5 03/12/2007 10:40:00 14.7 1.7 19.5 10.7 14.6 1.7 19.1 11.1 12.3 1.7 19.1 6.8 293 20 305 165 -8 0.1 -7.6 -8.5 03/12/2007 10:50:00 15.4 1.7 19.1 8.4 15.3 1.7 19.1 8 13 1.9 17.6 7.6 297 20 290 165 -7.7 0 -7.4 -8.1 03/12/2007 11:00:00 15.6 1.4 19.1 11.8 15.5 1.3 18.7 11.1 13.5 1.7 20.2 8.8 296 21 257 165 -7.5 0.1 -7 -7.6 03/12/2007 11:10:00 14 1.9 17.9 8.8 13.8 1.9 17.9 8.8 12.8 2.1 18.7 7.6 308 19 298 165 -6.9 0.2 -6.6 -7.4 03/12/2007 11:20:00 13.9 1.8 20.6 9.5 13.7 1.8 20.6 9.9 12.7 1.8 17.9 9.1 305 18 273 165 -6.7 0 -6.6 -7 03/12/2007 11:30:00 13.5 1.7 17.9 9.5 13.4 1.7 17.6 9.9 11.5 1.6 16.4 6.5 299 21 312 165 -6.7 0.1 -6.4 -7.2 03/12/2007 11:40:00 15.6 2.2 21.4 9.1 15.4 2.2 21 9.1 13.4 2.2 20.6 6.5 294 22 304 165 -6.7 0.2 -6.1 -7 03/12/2007 11:50:00 15.3 1.7 20.2 10.7 15.1 1.7 20.6 10.3 14 2.1 19.5 9.1 302 19 310 165 -6.7 0.2 -6.4 -7 03/12/2007 12:00:00 16.8 1.8 21.8 12.2 16.6 1.9 21.8 11.8 14.6 1.9 20.2 9.9 297 20 306 165 -6.7 0.1 -6.4 -6.8 03/12/2007 12:10:00 16.8 1.5 20.6 12.2 16.6 1.5 20.6 11.8 14.7 2.1 20.6 9.9 299 20 313 165 -6.5 0 -6.4 -6.8 03/12/2007 12:20:00 16.7 1.7 21 11.8 16.5 1.7 21 11.8 15.3 2 19.5 9.9 303 17 310 165 -6.6 0.1 -6.1 -6.8 03/12/2007 12:30:00 17.9 1.9 22.6 12.2 17.8 1.9 21.8 11.8 16.4 2.1 21.4 9.1 300 19 307 165 -6.7 0 -6.4 -6.8 03/12/2007 12:40:00 19.7 1.7 24 14.5 19.5 1.7 23.7 15.3 18 2.5 22.9 10.3 299 17 308 165 -6.8 0 -6.6 -6.8 03/12/2007 12:50:00 19.6 1.4 22.6 15.3 19.5 1.4 22.1 14.9 17.7 2.1 22.6 12.2 296 18 310 165 -7 0 -6.8 -7.2 03/12/2007 13:00:00 19.1 1.5 23.3 14.5 19 1.5 22.9 14.5 16.8 2.1 22.9 12.6 298 17 257 165 -6.9 0.1 -6.8 -7.2 03/12/2007 13:10:00 18.3 1.5 23.3 13.7 18.1 1.5 22.9 14.1 15.3 2 22.6 10.3 295 18 314 165 -6.8 0 -6.6 -7 03/12/2007 13:20:00 19.8 1.7 23.3 13.3 19.6 1.7 22.6 13.3 17.3 2.4 21.8 11.8 297 17 306 165 -6.8 0 -6.6 -7 03/12/2007 13:30:00 20.2 1.5 24 16.1 20 1.5 23.7 16.1 19 1.8 22.9 11.5 301 15 295 165 -6.8 0 -6.6 -7.2 03/12/2007 13:40:00 18.3 2.1 22.9 9.9 18.2 2.1 22.9 9.1 16.7 2.2 21.8 7.6 297 20 304 165 -6.7 0 -6.6 -6.8 03/12/2007 13:50:00 18.2 1.7 21.4 12.6 18 1.7 21.4 12.2 15.5 1.8 20.6 10.7 294 20 302 165 -6.6 0 -6.6 -6.8 03/12/2007 14:00:00 19.9 1.9 24.4 14.9 19.7 2 24 14.5 17 2.3 23.3 10.7 295 18 286 165 -6.7 0 -6.6 -6.8 03/12/2007 14:10:00 18.3 1.8 23.7 13.3 18.2 1.8 23.7 13.3 16.5 2.3 22.9 10.7 300 17 256 165 -6.5 0.1 -6.1 -6.8 03/12/2007 14:20:00 19.5 1.9 24.4 14.9 19.4 1.9 24.4 14.5 18.5 2.3 23.7 11.8 303 16 307 165 -6.5 0 -6.1 -6.6 03/12/2007 14:30:00 18.5 2 22.1 13.3 18.3 2 22.1 13 16.6 2.3 21.4 10.7 299 17 311 165 -6.5 0 -6.1 -6.6 03/12/2007 14:40:00 18.4 2.2 23.3 13.3 18.2 2.2 23.3 13 16.2 2.4 22.9 10.7 295 17 304 165 -6.5 0 -6.4 -6.6 03/12/2007 14:50:00 18.3 2.1 23.3 13 18.1 2 23.3 13 17.1 2.5 22.9 10.7 302 18 297 165 -6.4 0 -6.4 -6.6 03/12/2007 15:00:00 19.7 1.8 23.3 14.1 19.6 1.8 22.9 13.7 18.6 2.3 22.1 12.2 298 20 307 165 -6.6 0 -6.1 -6.8 03/12/2007 15:10:00 21.4 1.6 26 14.9 21.3 1.6 26 15.3 20.4 2.3 25.2 14.5 300 16 309 165 -6.8 0 -6.6 -6.8 03/12/2007 15:20:00 19.8 2.1 25.6 14.9 19.7 2.1 25.2 14.5 18.8 2.3 24 11.5 299 18 291 165 -6.8 0 -6.6 -6.8 03/12/2007 15:30:00 20.8 1.9 24.4 15.3 20.6 1.9 24 15.3 20 2.3 24.8 13 303 15 290 165 -6.7 0 -6.6 -6.8 03/12/2007 15:40:00 20.9 1.7 25.2 15.6 20.7 1.7 25.2 16.1 20.4 2 24.8 14.9 304 17 309 165 -6.6 0 -6.4 -6.8 03/12/2007 15:50:00 20.8 1.9 26 16.1 20.5 1.9 26 16.1 19.3 2.3 26 12.2 300 17 292 165 -6.4 0 -6.1 -6.6 03/12/2007 16:00:00 21 1.8 24 15.6 20.9 1.8 24 15.3 18.2 2 23.7 12.6 293 20 302 165 -6.5 0 -6.4 -6.6 03/12/2007 16:10:00 21.8 1.7 25.6 16.4 21.6 1.7 25.6 15.6 19.9 2.3 24.4 12.2 297 17 308 165 -6.6 0 -6.6 -6.8 03/12/2007 16:20:00 20.5 2.1 24.8 15.3 20.3 2.1 24.8 14.9 18.2 2.4 25.2 13.3 295 19 305 165 -6.7 0 -6.6 -6.8 03/12/2007 16:30:00 22.6 1.8 26 17.6 22.5 1.8 25.6 17.2 20.4 1.9 24.4 13.7 294 16 305 165 -7 0 -6.8 -7.2 03/12/2007 16:40:00 23 1.4 25.6 18.7 22.9 1.4 25.2 18.7 19.9 2.2 24.4 14.5 295 13 302 165 -7 0 -6.8 -7.2 03/12/2007 16:50:00 21.3 1.5 24.4 16.8 21.3 1.5 24.4 16.4 17.3 1.9 22.1 12.2 290 15 301 165 -7.1 0 -6.8 -7.2 03/12/2007 17:00:00 20.1 1.8 24.4 14.9 20.1 1.8 24.4 14.5 16.5 2.3 22.6 11.5 289 17 295 165 -7 0 -6.8 -7.2 03/12/2007 17:10:00 20.2 1.5 24 14.9 20.2 1.5 24 15.3 17 2.4 22.1 11.8 291 17 301 165 -6.9 0 -6.6 -7 03/12/2007 17:20:00 17.5 2.3 21.8 11.1 17.4 2.3 21.8 10.7 13.8 2.4 21 8 290 17 270 165 -6.9 0 -6.8 -7 03/12/2007 17:30:00 17.8 2.2 22.6 11.5 17.7 2.2 22.6 11.1 14.6 1.8 19.5 8.8 293 15 292 165 -7 0 -6.8 -7.2 03/12/2007 17:40:00 16.6 2.5 21.8 9.5 16.4 2.4 22.1 9.9 14.5 2.5 21.4 8.4 298 18 302 165 -7 0 -6.8 -7.2 03/12/2007 17:50:00 14.6 2.1 19.9 9.1 14.5 2.1 19.5 8.8 12.7 2.4 18.7 7.2 301 17 312 165 -6.8 0 -6.6 -7 03/12/2007 18:00:00 16.6 2.6 24 10.3 16.4 2.6 23.7 9.9 14.9 2.9 23.7 8 302 15 302 165 -6.8 0 -6.6 -7 03/12/2007 18:10:00 17.1 2.8 22.6 9.5 16.9 2.7 22.9 9.5 16 2.8 23.7 8.8 309 16 309 165 -6.8 0 -6.6 -6.8 03/12/2007 18:20:00 19.6 1.9 24.4 14.9 19.3 1.9 24.4 14.1 18.4 2.3 22.9 11.8 309 15 312 165 -6.8 0 -6.6 -6.8 03/12/2007 18:30:00 18.3 2.4 23.7 12.2 18.2 2.3 23.3 11.5 16.4 2.8 23.3 6.8 303 16 312 165 -6.8 0 -6.6 -7 03/12/2007 18:40:00 18.3 2.7 24 12.6 18.1 2.7 24 11.5 15.6 2.7 23.7 8.8 294 21 309 165 -7.2 0 -6.8 -7.2 03/12/2007 18:50:00 19.9 1.9 24.4 14.9 19.8 1.9 24 14.9 18.9 2.1 23.7 13 303 16 298 165 -7.3 0.1 -7 -7.4 03/12/2007 19:00:00 18.7 2.4 24.4 11.5 18.4 2.4 24 11.5 17.6 2.9 25.2 9.9 309 17 318 165 -7.5 0 -7.2 -7.6 03/12/2007 19:10:00 19.1 2.4 25.2 12.6 19 2.3 25.2 12.6 17 2.8 24.8 10.3 299 19 309 165 -7.6 0 -7.4 -7.6 03/12/2007 19:20:00 18.1 2.6 23.3 10.3 18.2 2.6 24.4 10.3 15.1 2.8 23.7 6.8 295 21 302 165 -7.6 0 -7.4 -7.9 03/12/2007 19:30:00 19.6 2.3 24.8 13.3 19.5 2.2 25.6 13.3 17.2 3.3 23.7 7.2 296 19 259 165 -7.5 0 -7.2 -7.6 03/12/2007 19:40:00 22 2.3 29.4 15.6 21.8 2.3 28.7 15.6 21.2 2.8 29.4 15.3 304 16 298 165 -7.6 0.2 -7.2 -7.9 03/12/2007 19:50:00 24.2 1.8 29.8 18.3 24 1.9 29.1 17.9 23.4 2.2 29.4 17.2 300 20 297 165 -8 0 -7.6 -8.1 03/12/2007 20:00:00 24.3 1.8 27.9 18.3 24.3 1.9 28.3 18.7 22.9 2 27.9 16.4 294 18 297 165 -7.8 0 -7.6 -8.1 03/12/2007 20:10:00 21.8 1.7 26.3 17.6 21.6 1.7 26 17.9 20.4 1.8 24.4 14.9 296 18 242 165 -7.6 0.1 -7.2 -8.1 03/12/2007 20:20:00 23.1 1.7 27.9 19.5 22.9 1.7 27.5 19.1 22.7 2 27.5 14.5 306 13 317 165 -7.5 0 -7.2 -7.6 03/12/2007 20:30:00 24.7 2.1 28.7 19.5 24.5 2.2 29.4 18.7 24.6 2.3 30.2 16.8 308 15 269 165 -7.5 0.1 -7.2 -7.9 03/12/2007 20:40:00 20.6 2.5 27.5 13.7 20.4 2.5 27.9 14.1 20.6 2.6 26.8 13.3 311 16 312 165 -7.4 0 -7.2 -7.6 03/12/2007 20:50:00 18.6 3.3 27.5 10.7 18.5 3.3 26.8 10.7 17.6 3.5 27.1 9.9 305 17 296 165 -7.2 0 -7 -7.4 03/12/2007 21:00:00 17.8 2.7 24.8 8.8 17.7 2.7 25.2 8.8 16.7 2.4 22.1 11.1 305 17 313 165 -7.1 0 -6.8 -7.2 03/12/2007 21:10:00 20.6 3.1 26.3 11.5 20.4 3.1 26.3 11.5 19.6 3.6 27.1 8.4 307 15 309 165 -7.2 0.1 -6.8 -7.2 03/12/2007 21:20:00 21.3 1.9 26.8 16.4 21.2 2 26.8 16.1 20.6 2.3 27.5 15.6 310 15 317 165 -7.1 0 -6.8 -7.2 03/12/2007 21:30:00 21.7 2.7 28.3 14.1 21.6 2.7 28.3 14.1 21.1 2.9 27.5 13 309 13 304 165 -6.8 0 -6.6 -7.2 03/12/2007 21:40:00 20.6 2.7 27.5 14.9 20.4 2.7 27.5 14.5 19.6 2.9 27.1 12.2 307 13 271 165 -6.9 0.1 -6.6 -7.2 03/12/2007 21:50:00 19.7 2.6 25.2 12.6 19.5 2.6 24.8 12.2 18.9 2.9 25.6 10.3 306 14 302 165 -7.1 0 -6.8 -7.2 03/12/2007 22:00:00 21.3 2.3 25.6 16.4 21 2.2 25.2 16.1 20.5 2.7 25.6 13 306 14 308 165 -7.1 0 -6.8 -7.4 03/12/2007 22:10:00 18.8 2 23.3 13 18.7 2 22.6 12.2 17.6 2.4 22.9 11.5 302 17 305 165 -7.1 0 -6.8 -7.2 03/12/2007 22:20:00 19.2 2.7 24.4 10.7 18.9 2.7 24 10.7 18.5 2.8 24 11.5 308 15 294 165 -7.1 0 -6.8 -7.2 03/12/2007 22:30:00 19.8 2.2 25.6 14.9 19.5 2.2 25.6 14.9 19.2 2.5 25.2 12.6 313 13 305 165 -7.1 0 -6.8 -7.4 03/12/2007 22:40:00 22.7 2.9 30.9 15.3 22.6 2.9 30.2 14.9 21.9 3.1 30.6 12.2 309 13 288 165 -7.1 0 -6.8 -7.2 03/12/2007 22:50:00 26.3 2.9 31.8 17.6 26.1 2.9 32.1 17.9 26 3.5 31.8 15.3 313 8 298 165 -7.2 0.1 -6.8 -7.4 03/12/2007 23:00:00 26.5 2.7 32.4 21 26.3 2.8 32.4 20.6 26.5 2.8 33.2 19.9 312 9 314 165 -7.6 0 -7.2 -7.6 03/12/2007 23:10:00 24.4 2 29.4 19.5 24.2 2 29.4 18.7 24.4 2.2 29.4 18.3 317 10 318 165 -7.6 0.1 -7.4 -8.1 03/12/2007 23:20:00 22.2 2.5 30.6 16.1 22.1 2.6 30.2 16.1 21.9 2.8 28.3 14.5 313 12 287 165 -7.3 0.1 -6.8 -7.6 03/12/2007 23:30:00 20.9 2.3 27.5 15.6 20.8 2.4 27.1 15.3 19.9 2.1 26.8 15.6 308 12 304 165 -7.2 0 -7 -7.4 03/12/2007 23:40:00 20.3 2.3 26.3 14.1 20.1 2.3 26.8 13.7 19.5 2.2 27.9 14.5 312 12 295 165 -7.4 0.1 -7.2 -7.4 03/12/2007 23:50:00 20.4 2.3 26 11.8 20.2 2.3 26 12.2 19.7 2.3 24.4 10.7 313 12 322 165 -7.3 0.1 -7 -7.6 03/13/2007 00:00:00 18 2.8 26.3 9.5 17.9 2.8 26.3 10.3 16.8 2.8 23.7 9.9 308 14 300 165 -7.4 0.2 -6.8 -7.6 03/13/2007 00:10:00 14.8 2.1 20.6 9.1 14.7 2 20.2 9.1 13.6 2.2 20.6 8.4 307 15 282 165 -7.3 0.2 -6.8 -7.6 03/13/2007 00:20:00 15.7 3.6 23.7 9.5 15.6 3.8 24 9.5 12.8 2.9 21.4 7.2 296 17 272 165 -7.7 0.2 -7.2 -8.1 03/13/2007 00:30:00 15.3 2.3 22.1 10.7 15.2 2.4 22.1 10.3 13.8 1.8 19.9 9.9 305 16 307 165 -7.9 0.1 -7.6 -8.1 03/13/2007 00:40:00 13.6 1.9 17.9 8.8 13.4 1.9 17.9 8.4 12.2 1.8 17.6 7.6 307 15 308 165 -7.8 0 -7.4 -8.1 03/13/2007 00:50:00 11.4 1.8 16.4 6.5 11.3 1.9 16.1 6.8 10.4 1.9 16.4 4.9 309 18 290 165 -7.4 0.2 -7 -7.6 03/13/2007 01:00:00 11.4 2 16.4 6.5 11.1 1.8 16.1 7.2 11 2.3 16.4 4.9 321 20 341 165 -7.8 0 -7.4 -8.1 03/13/2007 01:10:00 10 1.4 14.1 6.8 9.9 1.4 14.5 6.8 9.4 1.3 14.1 5.7 316 15 300 165 -8.1 0.1 -7.6 -8.3 03/13/2007 01:20:00 8.7 1.4 12.6 5.7 8.6 1.5 12.2 5.7 7.5 1.3 12.2 4.6 307 13 292 165 -7.8 0 -7.6 -8.1 03/13/2007 01:30:00 7.6 1.2 10.7 4.9 7 1.2 10.3 3.4 7.4 1.3 11.1 4.2 333 22 353 165 -7.6 0.1 -7.2 -7.9 03/13/2007 01:40:00 8.9 2 14.5 5.3 8.6 1.9 14.9 4.9 8.5 1.9 14.9 4.9 329 21 348 165 -7.2 0.1 -6.8 -7.6 03/13/2007 01:50:00 10.9 1.8 15.6 5.3 10.6 1.8 15.3 5.3 10.1 1.8 14.9 4.6 324 17 309 165 -7.6 0 -7.4 -7.9 03/13/2007 02:00:00 9.8 1.8 15.3 5.3 9.6 1.7 14.5 4.9 8.6 1.9 15.3 3.8 316 20 353 165 -7.6 0 -7.4 -7.9 03/13/2007 02:10:00 9.1 2.8 16.8 4.2 8.9 2.9 16.4 3.8 7.7 3.1 16.1 0.4 317 20 296 165 -7.5 0.4 -6.6 -7.9 03/13/2007 02:20:00 10.9 2.1 17.9 6.1 10.7 2.1 18.3 6.1 9.8 2.3 17.2 5.3 312 18 300 165 -7.1 0.2 -6.6 -7.4 03/13/2007 02:30:00 12 2.6 19.9 7.2 11.9 2.5 19.9 7.2 10.8 2.8 19.5 5.7 311 16 310 165 -7.4 0.1 -7 -7.6 03/13/2007 02:40:00 15 2.2 20.6 8.8 14.7 2.2 21 8.8 14.3 2.4 22.6 7.6 317 13 302 165 -7.5 0.1 -7.2 -7.9 03/13/2007 02:50:00 15.1 1.8 20.6 10.7 14.9 1.8 20.6 11.1 14.5 1.9 19.9 10.3 319 15 295 165 -7.6 0 -7.2 -7.9 03/13/2007 03:00:00 16.4 1.9 22.1 12.2 16 1.9 22.6 11.8 15.7 1.9 21 10.3 329 16 340 165 -7.6 0 -7.4 -7.9 03/13/2007 03:10:00 17.3 2.1 22.6 12.2 17 2 22.1 11.8 16.6 2.1 23.7 12.2 325 17 335 165 -7.8 0 -7.4 -8.1 03/13/2007 03:20:00 19.8 3.5 27.1 12.2 18.9 3.3 27.1 11.5 19.3 4 27.5 10.3 337 17 332 165 -7.8 0 -7.6 -8.1 03/13/2007 03:30:00 20.5 2.4 27.5 14.5 20 2.5 27.9 15.3 19.6 2.4 27.9 14.5 328 19 360 165 -7.8 0 -7.4 -8.1 03/13/2007 03:40:00 22.9 3.1 30.9 14.5 22.7 3.2 30.6 14.5 22.2 3.2 30.2 14.1 312 15 300 165 -7.4 0.1 -7.2 -7.6 03/13/2007 03:50:00 25.4 2.5 31.3 16.8 25.1 2.6 31.3 17.2 24.8 2.9 32.4 17.2 313 11 316 165 -7.3 0.1 -7 -7.4 03/13/2007 04:00:00 25.6 2.8 30.6 17.6 25.4 2.8 30.2 17.9 25.2 3.1 31.3 17.2 314 12 312 165 -7.5 0 -7.2 -7.9 03/13/2007 04:10:00 26.4 2.5 31.8 19.9 26.2 2.5 31.8 20.2 26.4 2.5 32.4 20.6 316 11 302 165 -7.8 0 -7.6 -7.9 03/13/2007 04:20:00 20.3 3.1 26.8 13 20 3.1 26.8 12.6 19.5 3.3 26.8 12.2 316 13 318 165 -7.9 0 -7.6 -8.1 03/13/2007 04:30:00 21.4 3.3 29.8 11.1 21.3 3.3 29.1 11.1 19.6 3.2 27.5 10.3 301 15 294 165 -8.1 0.1 -7.6 -8.3 03/13/2007 04:40:00 23.4 2.4 28.7 17.2 23.1 2.4 28.7 17.6 22.2 2.8 29.1 11.5 307 14 306 165 -8 0.1 -7.6 -8.3 03/13/2007 04:50:00 22.8 2.4 28.3 14.9 22.6 2.4 28.3 16.1 21.8 2.8 28.7 12.6 307 17 312 165 -7.8 0.1 -7.4 -8.1 03/13/2007 05:00:00 26 2.2 32.1 19.9 25.9 2.2 31.8 20.2 25.4 2.6 31.8 16.8 307 13 306 165 -8 0.1 -7.6 -8.3 03/13/2007 05:10:00 24.8 2.1 30.2 18.3 24.6 2.1 30.2 18.7 24.3 2.2 30.2 19.1 311 13 314 165 -8.2 0 -8.1 -8.5 03/13/2007 05:20:00 26.3 2.1 32.1 21 26.1 2.2 32.1 20.6 26 2.2 31.8 19.1 309 11 302 165 -8 0.1 -7.6 -8.3 03/13/2007 05:30:00 21.7 2.7 28.7 14.9 21.5 2.7 28.7 14.9 20.6 3.2 28.7 12.6 309 15 309 165 -8.1 0 -7.9 -8.3 03/13/2007 05:40:00 23.5 3.8 32.4 12.2 23.3 3.8 32.9 11.5 22.9 3.8 30.6 13 307 15 292 165 -7.9 0 -7.6 -8.5 03/13/2007 05:50:00 25.2 2.6 31.3 17.6 25 2.6 30.9 17.6 24.4 3.1 32.9 15.6 308 14 314 165 -8.1 0.2 -7.6 -8.5 03/13/2007 06:00:00 24.7 2.7 31.3 15.6 24.5 2.8 30.9 15.6 23.7 3.1 31.3 15.6 306 15 319 165 -8 0.1 -7.6 -8.3 03/13/2007 06:10:00 26.3 2.9 35.9 18.7 26.1 2.9 35.9 18.7 25.5 3.1 35.2 17.9 306 17 290 165 -8 0 -7.6 -8.3 03/13/2007 06:20:00 25.2 3.3 34 17.6 25.1 3.5 34.4 17.2 24.2 3.2 32.9 15.3 303 18 276 165 -8.1 0.1 -7.6 -8.3 03/13/2007 06:30:00 29.7 4.5 40.1 17.6 29.6 4.5 40.1 17.2 28.7 5.1 41.3 15.6 304 14 324 165 -8.4 0.2 -8.1 -8.9 03/13/2007 06:40:00 30 3.3 38.6 23.7 29.9 3.3 39 23.3 29.7 3.5 40.9 21.8 312 13 319 165 -8.4 0.3 -7.6 -8.9 03/13/2007 06:50:00 31.8 2.8 40.9 22.9 31.6 2.9 40.5 22.9 31.3 3.1 38.6 22.6 310 12 313 165 -8.1 0.1 -7.9 -8.5 03/13/2007 07:00:00 29.3 3.1 36.7 19.5 29.1 3.1 36.7 19.1 28.8 3.2 36.3 19.9 313 14 304 165 -8.2 0.2 -7.6 -8.5 03/13/2007 07:10:00 27.4 2.5 33.2 21.4 27.1 2.5 33.6 21 26.6 2.8 34.4 17.9 312 13 269 165 -8 0.2 -7.6 -8.3 03/13/2007 07:20:00 29 3.1 35.9 20.6 28.8 3.1 35.5 20.2 28.4 3.3 35.5 19.5 309 12 326 165 -8 0.1 -7.6 -8.3 03/13/2007 07:30:00 29.8 2.7 36.3 22.1 29.5 2.7 35.5 22.1 29 2.9 35.2 20.6 311 11 310 165 -8 0 -7.6 -8.1 03/13/2007 07:40:00 30.6 2.9 35.9 20.6 30.3 2.8 35.2 19.9 29.7 3.3 36.7 20.2 312 13 316 165 -8 0 -7.6 -8.1 03/13/2007 07:50:00 30.4 2.4 34.8 21.4 30.1 2.4 34.4 21.8 29.4 2.9 35.2 18.7 310 11 302 165 -8.1 0 -7.6 -8.5 03/13/2007 08:00:00 30.3 2.7 35.5 20.2 30.1 2.7 35.5 20.2 29.8 3.1 35.5 19.9 309 12 308 165 -8.6 0.1 -8.3 -8.7 03/13/2007 08:10:00 28.6 2.4 34.8 22.1 28.4 2.4 34.4 22.6 27.9 2.9 34.8 19.5 308 13 324 165 -8.5 0.1 -8.3 -8.9 03/13/2007 08:20:00 24.5 3.1 31.3 16.1 24.4 3.1 31.8 16.1 23 3.5 32.1 12.6 308 14 304 165 -8.5 0 -8.5 -8.7 03/13/2007 08:30:00 23.6 3.1 29.4 13.3 23.4 2.9 29.4 13 22.1 3.5 29.4 11.8 309 13 318 165 -8.7 0 -8.5 -8.9 03/13/2007 08:40:00 25.5 2.8 32.4 16.4 25.3 2.7 32.4 16.8 24 2.9 30.9 15.3 306 13 318 165 -8.5 0.1 -8.3 -8.9 03/13/2007 08:50:00 23.7 2.7 32.9 15.6 23.6 2.8 32.1 15.6 22.8 2.8 31.8 15.3 309 16 307 165 -8.3 0.1 -7.9 -8.5 03/13/2007 09:00:00 25.6 2.9 32.1 15.6 25.5 2.9 32.1 15.6 24.5 2.9 31.8 14.9 309 13 300 165 -8 0 -7.6 -8.1 03/13/2007 09:10:00 24 2.4 29.4 15.3 23.7 2.3 29.4 15.3 22.3 2.8 31.3 12.6 307 14 322 165 -8 0.1 -7.6 -8.3 03/13/2007 09:20:00 24.1 3.1 29.4 14.5 23.9 3.1 29.4 14.5 22.9 3.5 29.8 13.7 309 12 314 165 -8.2 0 -8.1 -8.5 03/13/2007 09:30:00 23.1 2.3 27.5 15.6 22.9 2.3 27.5 15.6 22.3 2.6 28.7 13.7 310 13 310 165 -8.4 0.1 -8.1 -8.5 03/13/2007 09:40:00 22.9 2.3 28.3 14.1 22.7 2.3 27.9 14.9 22.2 2.6 31.3 14.1 310 15 301 165 -8.3 0 -8.1 -8.7 03/13/2007 09:50:00 23.9 2.3 29.1 16.8 23.7 2.4 29.4 16.8 23.3 2.5 29.4 17.6 309 12 310 165 -8.2 0 -8.1 -8.7 03/13/2007 10:00:00 25.2 2.6 31.3 18.3 25 2.7 30.9 17.9 24.4 3.2 31.8 14.9 310 13 321 165 -7.9 0.1 -7.6 -8.5 03/13/2007 10:10:00 26.2 2.7 33.2 17.6 25.9 2.7 33.2 17.2 25.8 2.9 33.6 18.3 312 12 298 165 -7.8 0.3 -7.2 -8.1 03/13/2007 10:20:00 26.4 2.6 34 16.1 26.2 2.6 34 15.3 25.4 3.1 32.9 16.1 309 13 311 165 -7.6 0 -7.4 -7.6 03/13/2007 10:30:00 24.3 2.4 30.2 17.9 24.2 2.5 30.6 17.6 23.4 2.8 29.8 16.1 310 12 311 165 -7.4 0.2 -6.8 -8.1 03/13/2007 10:40:00 23.2 2.7 29.4 16.4 23.1 2.7 29.1 16.4 22.2 2.8 28.7 15.3 310 10 291 165 -7.1 0.3 -6.6 -7.6 03/13/2007 10:50:00 23 2 29.4 17.6 22.7 2.1 29.4 17.6 21.5 2.6 29.1 14.5 310 10 312 165 -6.9 0.1 -6.6 -7.2 03/13/2007 11:00:00 22.1 3.1 29.4 14.9 21.8 2.9 29.1 15.3 20.6 3.1 28.7 13.3 311 11 306 165 -6.4 0.2 -5.7 -6.8 03/13/2007 11:10:00 21.7 2.8 28.3 14.1 21.6 2.8 27.9 14.1 19.5 2.9 26.8 10.7 306 11 297 165 -6.6 0.1 -6.4 -6.8 03/13/2007 11:20:00 20.8 2.8 29.8 13 20.8 2.7 30.2 12.6 17.5 3.3 26.3 8.4 305 12 324 165 -6.2 0.2 -5.9 -6.8 03/13/2007 11:30:00 23.2 2.7 30.2 14.1 23.1 2.7 29.1 14.5 20.2 3.1 28.3 8.8 306 13 292 165 -6.3 0.2 -5.7 -6.8 03/13/2007 11:40:00 23.2 2.7 30.6 15.6 23.1 2.7 30.2 15.6 20.6 3.3 29.4 12.6 308 12 309 165 -6.4 0 -6.1 -6.6 03/13/2007 11:50:00 25.5 2.8 32.4 16.8 25.4 2.7 32.4 17.6 23.6 3.2 32.9 15.6 309 11 313 165 -6.6 0.1 -6.4 -6.8 03/13/2007 12:00:00 28.4 3.2 35.5 17.9 28.2 3.2 35.2 17.6 27.9 3.6 36.7 17.2 317 12 306 165 -6.6 0.2 -6.1 -7 03/13/2007 12:10:00 28.5 2.7 34.4 21.8 28.4 2.7 34.4 21.4 28.1 2.9 34 19.1 313 11 327 165 -6.8 0.1 -6.6 -7 03/13/2007 12:20:00 30.6 1.9 35.2 24.4 30.5 2 34.8 24 30.5 2.3 35.9 23.3 314 7 294 165 -6.9 0 -6.8 -7 03/13/2007 12:30:00 30.5 2.2 35.9 23.3 30.4 2.3 36.3 23.3 30.3 2.4 34.8 22.9 313 7 307 165 -6.6 0 -6.4 -6.8 03/13/2007 12:40:00 31.5 2.1 35.5 24.8 31.7 2.2 36.7 24.8 31.9 2.1 36.7 24.8 312 8 312 165 -6.7 0 -6.6 -6.8 03/13/2007 12:50:00 30.8 1.7 34 24.4 31.1 1.8 34.8 23.7 31.3 2.2 35.2 22.9 313 7 300 165 -6.7 0 -6.6 -6.8 03/13/2007 13:00:00 31 2 35.2 23.7 30.8 2.1 35.2 23.7 30.9 2.3 34.8 22.6 313 6 310 165 -6.6 0 -6.4 -6.8 03/13/2007 13:10:00 30.1 1.9 34.8 23.7 29.9 1.9 34.8 24 29.7 2.2 34.8 23.7 313 8 300 165 -6.4 0 -6.1 -6.8 03/13/2007 13:20:00 28.9 2.2 33.6 21.4 28.6 2.2 32.9 21.4 28.2 2.5 34 20.6 313 8 307 165 -6.4 0 -6.1 -6.6 03/13/2007 13:30:00 28.4 2.5 33.2 20.2 28.2 2.6 33.2 20.6 28.1 2.8 34.4 19.5 313 9 306 165 -6.2 0 -5.9 -6.6 03/13/2007 13:40:00 27.4 2.1 32.4 21.8 27.2 2.2 32.1 21.8 27 2.5 34.4 19.5 314 9 299 165 -6.1 0 -5.7 -6.4 03/13/2007 13:50:00 26.7 2.5 32.4 21 26.5 2.5 32.9 20.2 26.4 2.7 32.9 16.8 316 11 301 165 -6.1 0 -5.7 -6.6 03/13/2007 14:00:00 25.6 2.4 32.1 19.1 25.4 2.5 32.1 18.7 24.8 2.6 31.3 17.6 311 12 306 165 -5.9 0 -5.7 -6.1 03/13/2007 14:10:00 23.9 2.1 29.4 16.8 23.8 2.1 29.4 16.8 23.2 2.4 29.8 15.6 313 14 302 165 -6 0 -5.7 -6.1 03/13/2007 14:20:00 24 2.7 30.9 18.3 23.7 2.7 30.9 18.3 23.4 2.8 29.8 16.4 314 10 310 165 -6 0 -5.7 -6.4 03/13/2007 14:30:00 25.6 2.7 32.1 17.6 25.3 2.7 32.4 17.6 25.1 2.9 31.8 16.8 316 10 302 165 -6.1 0 -5.9 -6.6 03/13/2007 14:40:00 26.1 2.5 32.1 19.5 26 2.6 32.4 19.1 25.9 2.5 32.1 18.3 314 13 310 165 -6.2 0 -5.9 -6.4 03/13/2007 14:50:00 26.1 2.6 33.6 18.7 25.9 2.6 32.9 19.1 25.6 2.7 32.4 18.7 314 12 298 165 -6.2 0.1 -5.9 -6.6 03/13/2007 15:00:00 27.2 2.1 32.4 20.6 27.1 2.1 32.4 20.6 26.9 2.5 32.4 19.5 312 10 309 165 -6.5 0 -6.1 -6.6 03/13/2007 15:10:00 25.9 2.5 31.8 19.1 25.7 2.6 31.8 19.1 25.5 2.6 32.1 18.7 315 12 314 165 -6.4 0.1 -6.1 -6.8 03/13/2007 15:20:00 26.1 2.3 30.9 19.1 26 2.3 30.9 18.7 25.6 2.6 31.8 19.1 313 11 300 165 -6.4 0 -6.1 -6.6 03/13/2007 15:30:00 25 2.4 30.2 18.3 24.8 2.4 30.2 17.2 24.6 2.7 30.9 16.8 315 10 322 165 -6.4 0 -6.1 -6.8 03/13/2007 15:40:00 23 3.5 30.2 14.5 22.7 3.6 30.6 13.3 22.7 3.6 30.9 13.3 318 15 313 165 -6.4 0 -6.1 -6.8 03/13/2007 15:50:00 20 2 25.6 15.6 19.7 2 25.6 15.3 19.5 1.8 24.4 14.9 316 12 321 165 -6.6 0 -6.4 -6.8 03/13/2007 16:00:00 19.6 2.2 27.1 12.6 19.5 2.2 27.1 13 19 2.4 25.6 11.1 315 13 294 165 -6.7 0 -6.6 -7 03/13/2007 16:10:00 21.8 2.3 30.6 15.6 21.6 2.3 30.9 16.8 21.4 2.4 30.2 15.3 319 13 320 165 -6.8 0 -6.6 -7 03/13/2007 16:20:00 21.2 2.4 27.1 14.5 21 2.4 27.5 14.5 20.5 2.4 27.5 14.9 314 10 310 165 -6.7 0 -6.6 -7.2 03/13/2007 16:30:00 20.8 2.4 32.1 14.9 20.6 2.4 32.1 14.9 20.1 2.2 26 14.1 314 15 248 165 -6.7 0 -6.6 -6.8 03/13/2007 16:40:00 18.9 2.7 26.3 13.3 18.7 2.6 25.6 13.3 18 2.8 24.8 11.1 312 15 309 165 -6.7 0 -6.6 -6.8 03/13/2007 16:50:00 19 2.5 25.6 12.6 18.8 2.5 25.6 12.2 17.6 2.2 23.7 11.5 313 16 293 165 -6.7 0 -6.4 -6.8 03/13/2007 17:00:00 16.3 2.3 23.3 8 16.2 2.4 22.9 7.2 15.9 2.2 24.4 10.3 320 18 333 165 -6.5 0.1 -6.4 -6.8 03/13/2007 17:10:00 13.4 2.3 19.5 8.4 13.2 2.3 19.1 8.4 12.4 2.1 18.7 8 315 17 282 165 -6.4 0 -6.1 -6.6 03/13/2007 17:20:00 13.6 2.9 22.9 4.9 13.5 2.8 23.3 5.7 12.9 2.8 21.4 6.5 315 17 306 165 -6.4 0.1 -6.1 -6.8 03/13/2007 17:30:00 10.7 2.3 17.2 5.3 10.1 2.3 17.2 4.6 10 2.3 16.8 5.3 338 17 351 165 -6.8 0.2 -6.6 -7.2 03/13/2007 17:40:00 12.5 2.7 18.3 6.5 11.4 2.8 18.7 5.7 12.2 2.7 18.7 6.5 343 15 319 165 -7.2 0.2 -6.8 -7.6 03/13/2007 17:50:00 15.3 3.1 24.8 9.1 14.6 3.5 25.6 7.6 15.4 3.2 22.9 7.6 340 16 343 165 -7.6 0 -7.4 -7.9 03/13/2007 18:00:00 12.5 2.6 19.9 6.5 11.7 2.2 17.9 6.1 11.7 2.7 17.9 4.6 326 23 357 165 -7.9 0 -7.6 -8.1 03/13/2007 18:10:00 12.1 2.2 17.6 6.1 11.8 2.2 17.2 6.5 11.3 2 16.4 6.8 319 19 301 165 -8.2 0 -8.1 -8.5 03/13/2007 18:20:00 12 2.6 21.4 6.8 11.4 2.2 19.1 6.5 11.2 2.5 19.9 5.3 330 21 347 165 -8.5 0 -8.3 -8.7 03/13/2007 18:30:00 9.4 2.7 17.2 3.4 9.1 2.6 16.4 4.2 8.8 2.7 17.2 3 326 22 331 165 -8.6 0 -8.5 -8.7 03/13/2007 18:40:00 9.2 2.5 16.8 3.8 8.9 2.5 16.4 3.4 8.3 2.2 16.1 3.8 322 24 298 165 -8.8 0 -8.7 -8.9 03/13/2007 18:50:00 5.6 3.1 14.5 0.4 5.3 2.8 13.7 0.4 5.1 3.2 13.3 0.4 299 53 322 165 -9.1 0.1 -8.9 -9.1 03/13/2007 19:00:00 5.2 3.2 13 0.4 5 3.1 13.7 0.4 4.9 3.2 13.7 0.4 314 72 341 165 -9.1 0 -8.9 -9.1 03/13/2007 19:10:00 5.9 2.6 13.7 0.4 5.5 2.4 13.3 0.4 5.6 2.4 13 1.1 336 23 333 165 -9.2 0.1 -8.9 -9.7 03/13/2007 19:20:00 6.5 3.5 16.8 0.7 6.1 3.1 14.5 0.7 6.3 3.2 14.5 1.1 338 41 355 165 -9.6 0.1 -9.3 -9.7 03/13/2007 19:30:00 6.1 1.7 11.1 2.3 5.6 1.6 9.5 2.3 5.9 1.9 10.3 1.9 338 22 6 165 -9.6 0.1 -9.3 -10 03/13/2007 19:40:00 8.8 2.3 14.9 3 8.6 2.4 15.3 3.4 8.7 2.3 14.5 4.2 338 12 334 165 -10.1 0.2 -9.7 -10.4 03/13/2007 19:50:00 6 1.4 10.3 1.9 5.2 1.7 10.3 1.9 5.9 1.4 10.7 3 358 18 338 165 -10.2 0 -10.2 -10.6 03/13/2007 20:00:00 6.1 1.3 9.9 2.6 5.5 1.3 9.9 2.3 5.9 1.3 9.5 3 339 20 346 165 -10.6 0 -10.4 -10.8 03/13/2007 20:10:00 9 2.4 14.5 3.8 8.8 2.4 14.1 4.2 8.1 1.9 13 4.2 326 18 322 165 -10.7 0 -10.6 -11 03/13/2007 20:20:00 11.8 1.5 16.4 8 11.6 1.5 16.1 8 11.1 1.5 14.5 8 315 12 306 165 -10.7 0.1 -10.4 -11 03/13/2007 20:30:00 12.5 2.3 18.3 7.6 12.3 2.3 19.9 7.2 12.2 2.3 17.6 7.2 328 13 319 165 -10.8 0 -10.6 -11.2 03/13/2007 20:40:00 15.7 2.4 22.9 10.7 15.5 2.5 22.9 10.7 14.7 2.2 20.6 9.9 312 12 293 165 -10.8 0 -10.6 -11 03/13/2007 20:50:00 16.3 1.5 20.6 13 16.1 1.6 20.6 12.6 15.2 1.9 19.9 10.7 309 11 281 165 -11 0 -10.8 -11.4 03/13/2007 21:00:00 17 2.2 22.6 11.5 16.9 2.2 22.6 11.1 15.8 2.5 22.6 8.8 309 13 302 165 -11 0 -10.8 -11.4 03/13/2007 21:10:00 16.1 2.2 22.1 11.5 15.9 2.3 21.4 10.7 15.2 2.2 21 9.9 314 15 313 165 -10.8 0.1 -10.4 -11.4 03/13/2007 21:20:00 12.8 2.5 19.9 8.4 12.5 2.4 19.5 7.6 11.6 2.4 19.5 6.5 317 17 328 165 -10.4 0.1 -10.2 -11 03/13/2007 21:30:00 9.4 1.7 15.6 4.9 9.3 1.7 15.3 5.3 8.3 1.7 12.6 4.6 317 18 320 165 -11 0 -10.8 -11.4 03/13/2007 21:40:00 8.9 1.8 14.5 4.9 8.7 1.7 14.1 4.6 7.9 1.7 13.3 3.8 328 19 330 165 -11 0 -11 -11.4 03/13/2007 21:50:00 12.2 2.7 19.1 4.9 11.4 2.6 18.7 4.9 11.6 2.7 16.8 3 336 18 357 165 -11 0 -10.8 -11.4 03/13/2007 22:00:00 12.9 2.3 19.1 8.4 12.4 2 17.6 8.4 12.2 2 17.6 6.8 330 18 326 165 -11.1 0 -11 -11.4 03/13/2007 22:10:00 15.3 3.1 23.7 7.6 13.6 2.8 19.9 6.8 14.2 3.3 22.6 6.8 343 17 354 165 -10.8 0.1 -10.6 -11.4 03/13/2007 22:20:00 15.7 2.6 22.9 10.3 15.1 2.4 22.1 9.9 14.6 2.5 21.8 9.1 328 19 341 165 -10.9 0 -10.6 -11 03/13/2007 22:30:00 17.3 2.4 23.3 12.2 17.1 2.4 23.3 12.2 16 2.4 23.3 10.7 313 17 301 165 -10.7 0 -10.4 -11 03/13/2007 22:40:00 17.8 2.3 26.3 11.5 17.3 2.1 24.4 11.8 17.2 2.2 23.3 11.5 321 17 351 165 -10.5 0.1 -10.2 -10.8 03/13/2007 22:50:00 19.1 2.4 26.8 13 19 2.3 26.8 12.2 18.3 2.4 25.2 11.5 309 15 312 165 -10.6 0 -10.4 -10.8 03/13/2007 23:00:00 22.8 2 27.9 17.2 22.6 2.1 27.5 16.8 22.1 2.3 28.7 15.3 311 11 308 165 -10.6 0 -10.4 -11 03/13/2007 23:10:00 22 1.7 27.1 17.6 21.8 1.7 26.8 17.6 21.4 1.7 26.8 17.2 310 9 314 165 -10.8 0 -10.6 -11 03/13/2007 23:20:00 20 1.9 25.2 14.5 19.8 2 25.2 13.7 19.2 2.1 25.2 14.1 308 13 288 165 -10.8 0.1 -10.6 -11 03/13/2007 23:30:00 18.2 2.2 22.9 12.6 18 2.2 22.9 12.6 16.8 2.1 23.7 11.8 310 15 312 165 -10.8 0 -10.6 -11 03/13/2007 23:40:00 16.5 1.8 21 11.1 16.4 1.8 21.8 11.5 15.4 1.8 19.5 10.7 312 16 298 165 -10.7 0 -10.6 -11 03/13/2007 23:50:00 16.6 1.8 22.6 11.5 16.4 1.8 22.1 11.5 15.7 1.9 20.2 10.7 315 16 271 165 -10.7 0.1 -10.6 -11 03/14/2007 00:00:00 16.2 2 20.6 11.8 16 2.1 20.6 11.5 15 2.2 20.2 9.1 311 17 270 165 -10.6 0 -10.4 -10.8 03/14/2007 00:10:00 18 2.2 23.3 12.6 17.9 2.2 23.7 12.6 17.4 2.3 23.7 11.8 310 13 311 165 -10.5 0 -10.2 -11 03/14/2007 00:20:00 17.4 1.6 22.6 13.7 17.2 1.6 22.6 13.3 16.4 2 22.1 11.1 306 12 305 165 -10.6 0 -10.6 -11 03/14/2007 00:30:00 16.6 1.9 26 13 16.5 1.9 25.6 13 15.8 1.7 22.6 11.1 309 13 318 165 -10.7 0 -10.6 -11 03/14/2007 00:40:00 15.6 1.8 20.2 9.5 15.4 1.8 19.9 10.3 15.2 1.9 19.9 9.5 316 14 333 165 -10.6 0 -10.4 -10.8 03/14/2007 00:50:00 14.5 1.8 19.5 10.3 14.4 1.7 19.9 10.7 14 1.7 19.1 9.1 314 14 310 165 -10.6 0 -10.6 -11 03/14/2007 01:00:00 15.7 2.1 21.8 9.9 15.6 2.2 22.1 9.9 15 1.9 21.4 9.9 313 17 304 165 -10.5 0 -10.4 -11 03/14/2007 01:10:00 16.1 2.1 23.3 9.1 15.9 2.3 23.3 8.4 15.4 2.1 21 9.9 315 17 313 165 -10.6 0 -10.4 -11 03/14/2007 01:20:00 16.3 2.3 23.3 9.5 16.2 2.3 22.1 9.1 15.3 2.5 21.4 9.1 311 17 289 165 -10.7 0 -10.4 -11 03/14/2007 01:30:00 15.2 2.4 22.1 9.9 15.1 2.4 21.8 9.1 14.7 2.3 21.4 9.5 312 17 295 165 -10.6 0.1 -10.4 -10.8 03/14/2007 01:40:00 14.8 2 22.9 10.7 14.6 2.1 22.9 10.3 14 2 22.9 9.5 317 21 336 165 -10.5 0 -10.4 -11 03/14/2007 01:50:00 16.4 2.1 22.9 11.5 16.2 2.2 22.9 11.1 15.8 2.1 21.4 8.8 320 21 318 165 -10.3 0.1 -10.2 -10.8 03/14/2007 02:00:00 14.3 1.7 19.5 9.5 14.2 1.7 19.1 9.9 13.7 1.9 18.3 8.4 314 17 273 165 -10.4 0 -10.2 -10.6 03/14/2007 02:10:00 14.4 1.3 19.5 9.9 14.2 1.3 18.3 10.3 13.3 1.7 17.6 9.1 306 15 309 165 -10.5 0 -10.4 -10.8 03/14/2007 02:20:00 13.2 1.6 17.9 8.8 13 1.6 17.6 8.4 12.7 1.6 16.4 8.8 313 17 312 165 -10.5 0 -10.4 -11 03/14/2007 02:30:00 11.5 1.5 16.1 7.2 11.3 1.4 15.3 6.8 10.9 1.4 14.9 7.2 326 18 350 165 -10.6 0.1 -10.4 -10.8 03/14/2007 02:40:00 12.3 1.6 16.1 8.4 12.2 1.6 16.4 8.4 11.9 1.6 15.6 7.6 326 16 348 165 -10.6 0 -10.6 -10.8 03/14/2007 02:50:00 10.2 1.5 15.3 6.1 9.9 1.6 15.6 5.3 9.8 1.7 14.1 5.7 324 18 312 165 -10.7 0.1 -10.6 -11 03/14/2007 03:00:00 12.7 2.8 19.9 7.6 12.5 2.8 19.9 7.2 11.8 2.8 21.4 6.1 309 17 294 165 -10.8 0.1 -10.6 -11 03/14/2007 03:10:00 12.6 2 18.3 8 12.5 2 18.7 8.4 11.5 1.8 16.8 7.2 305 19 302 165 -10.7 0 -10.6 -11 03/14/2007 03:20:00 13.1 2.4 19.5 6.8 13 2.5 19.5 6.5 12 2.4 19.1 5.7 305 20 307 165 -10.5 0 -10.4 -11 03/14/2007 03:30:00 13.1 2.2 17.9 8 13 2.2 17.9 7.6 12.1 2.1 17.9 7.6 307 21 313 165 -10.6 0 -10.4 -11 03/14/2007 03:40:00 10.3 2.1 14.5 5.3 10.1 2.2 15.3 4.9 9.7 2.2 16.8 4.6 315 23 295 165 -10.4 0 -10.2 -10.6 03/14/2007 03:50:00 10.8 1.8 16.4 6.5 10.7 1.9 16.1 6.8 9.6 1.9 16.4 5.7 303 18 278 165 -10.5 0.1 -10.2 -11 03/14/2007 04:00:00 8.6 1.8 15.3 3.4 8.5 1.8 14.9 4.2 7.9 1.5 13 4.2 308 21 291 165 -10.8 0 -10.6 -11 03/14/2007 04:10:00 13.3 2.7 20.2 6.1 13.2 2.8 20.6 6.1 11.3 2.7 19.1 6.1 298 17 304 165 -10.8 0.1 -10.4 -11 03/14/2007 04:20:00 15.3 2.2 21.4 8.8 15.2 2.2 20.6 8.8 14 2.4 21 7.2 300 19 260 165 -11 0 -10.8 -11.4 03/14/2007 04:30:00 15.7 2 22.1 11.1 15.4 2 21.8 10.7 14.6 2 20.6 9.9 306 16 309 165 -11.2 0 -11 -11.4 03/14/2007 04:40:00 15.6 2.2 20.6 9.5 15.4 2.2 20.2 9.9 14.3 2.4 21 9.5 305 19 332 165 -11.1 0.1 -10.8 -11.4 03/14/2007 04:50:00 16.3 2.4 21.8 10.3 16.2 2.4 21.4 10.3 15.4 2.7 22.1 9.1 301 20 300 165 -11.1 0 -11 -11.4 03/14/2007 05:00:00 15 2.2 20.2 9.9 14.9 2.1 20.2 9.9 13 2.2 19.1 7.6 297 18 303 165 -11.3 0.1 -11 -11.4 03/14/2007 05:10:00 12.5 2.2 21.4 6.8 12.3 2.2 21.4 6.1 11 1.8 16.8 6.5 305 24 297 165 -11.3 0 -11 -11.6 03/14/2007 05:20:00 12.4 1.9 17.9 7.6 12.3 1.9 18.3 8 11.2 1.7 18.3 6.8 306 22 331 165 -11.1 0 -10.8 -11.4 03/14/2007 05:30:00 14.2 2.8 21.4 8 14.1 2.8 21 8 13.2 2.9 21.4 7.2 305 22 285 165 -11.2 0 -11 -11.4 03/14/2007 05:40:00 11.7 3.5 22.6 3 11.6 3.5 22.6 4.2 10.6 3.5 23.7 3.8 308 20 322 165 -11.1 0 -10.8 -11.4 03/14/2007 05:50:00 16.4 2.8 27.5 8 16.2 2.8 28.3 9.5 15.5 2.9 26.8 9.9 309 22 307 165 -11.1 0 -11 -11.2 03/14/2007 06:00:00 18.5 2.4 26 12.6 18.3 2.5 26 12.2 17.7 2.4 27.1 11.1 310 21 330 165 -11.2 0 -11 -11.4 03/14/2007 06:10:00 20.4 3.3 28.7 13 20.2 3.3 27.9 13 19.5 3.5 27.5 10.7 310 18 301 165 -11.1 0 -10.8 -11.4 03/14/2007 06:20:00 17.5 2.8 26.3 10.7 17.4 2.8 26.3 11.1 16.3 3.2 26 9.5 303 20 305 165 -11 0.1 -10.8 -11.4 03/14/2007 06:30:00 13.8 3.6 24.4 5.3 13.7 3.6 24.8 4.9 12.8 4 22.6 2.3 308 22 312 165 -11.1 0 -11 -11.4 03/14/2007 06:40:00 12.2 2.6 18.3 6.5 12.1 2.6 18.7 6.5 10.9 2.4 18.3 5.7 302 17 284 165 -11.2 0 -11 -11.4 03/14/2007 06:50:00 11.3 2.6 18.3 4.9 11.1 2.6 18.7 4.9 10.1 2.5 17.9 5.3 306 20 291 165 -11.4 0 -11.2 -11.6 03/14/2007 07:00:00 13.6 2.6 21.8 8 13.5 2.5 21 7.6 12.6 2.5 19.9 6.5 305 21 304 165 -11.3 0.1 -11.2 -11.8 03/14/2007 07:10:00 13.5 2.6 22.1 7.6 13.4 2.6 21.8 8 12.2 2.4 20.6 7.2 301 22 289 165 -11.3 0 -11.2 -11.4 03/14/2007 07:20:00 14.7 2.1 20.2 9.5 14.6 2.2 20.2 9.1 12.8 1.8 19.1 8.4 300 22 302 165 -11.4 0 -11.4 -11.6 03/14/2007 07:30:00 16.5 2.7 25.2 10.7 16.4 2.7 25.2 11.1 15.5 2.9 23.7 9.5 304 22 307 165 -11.3 0.1 -11.2 -11.8 03/14/2007 07:40:00 13.2 1.8 18.7 9.1 13 1.8 18.7 9.5 12.1 2 18.7 7.6 301 19 297 165 -11.3 0 -11.2 -11.4 03/14/2007 07:50:00 15.2 2.1 21 8.4 15.1 2.1 20.6 8.8 14.3 2.2 19.5 8.4 304 21 310 165 -11.3 0 -11.2 -11.6 03/14/2007 08:00:00 17.2 2.3 23.3 9.9 17 2.3 23.3 10.3 16.6 2.4 23.3 9.9 304 17 278 165 -11.4 0 -11.2 -11.6 03/14/2007 08:10:00 16.2 2.5 22.6 11.1 16 2.5 22.6 11.1 15.7 2.5 23.3 10.7 312 18 315 165 -11 0.1 -10.6 -11.4 03/14/2007 08:20:00 14.3 2.2 19.5 9.5 14.1 2.1 19.5 9.5 13.8 2.3 20.2 7.6 312 20 310 165 -10.8 0 -10.6 -11 03/14/2007 08:30:00 15 2.7 23.3 9.9 14.9 2.6 22.6 10.3 14.5 2.8 21.8 8.8 318 20 273 165 -10.7 0 -10.6 -11 03/14/2007 08:40:00 15 2 20.2 10.3 14.9 2.1 20.2 10.3 14.3 2.2 19.9 9.1 309 19 316 165 -10.7 0 -10.6 -10.8 03/14/2007 08:50:00 15.9 2.1 22.6 8.4 15.7 2.2 22.1 6.1 15.2 2.1 21 8.4 308 19 299 165 -10.7 0 -10.4 -11 03/14/2007 09:00:00 15.9 2.1 23.3 10.7 15.8 2.2 23.3 10.3 15.3 2.5 21.8 9.1 309 22 280 165 -10.4 0 -10.4 -10.6 03/14/2007 09:10:00 14.7 2.5 21 8.4 14.7 2.5 20.6 8 13.8 2.7 21.4 8 304 22 313 165 -10.4 0.1 -10.2 -10.8 03/14/2007 09:20:00 14.5 2.1 20.6 9.5 14.3 2.1 20.2 9.9 14.1 2.2 21.4 9.1 311 17 302 165 -10.3 0 -10 -10.6 03/14/2007 09:30:00 15.7 1.7 19.9 11.1 15.5 1.7 19.9 10.7 15.3 1.7 20.6 10.3 311 17 314 165 -10.2 0.1 -10 -10.4 03/14/2007 09:40:00 16.5 2.2 22.9 9.1 16.3 2.1 21 9.5 16 2.3 22.1 10.7 317 20 360 165 -10.1 0.1 -9.7 -10.4 03/14/2007 09:50:00 18.1 2.8 24.8 10.7 16.9 3.1 24.4 10.3 17.7 2.8 24 9.9 340 15 354 165 -9.5 0 -9.3 -10 03/14/2007 10:00:00 15 3.3 23.3 6.8 14.8 3.3 24 6.5 14.8 3.5 22.9 5.7 335 16 346 165 -9.5 0.1 -9.1 -9.7 03/14/2007 10:10:00 12.9 2.7 19.1 5.7 12.8 2.9 19.9 5.7 12.8 2.7 17.9 6.8 334 16 336 165 -9.2 0.1 -9.1 -9.5 03/14/2007 10:20:00 11.9 2.4 18.7 6.5 11.3 2.7 18.7 5.3 11.6 2.4 18.7 6.8 338 22 338 165 -9 0.1 -8.9 -9.3 03/14/2007 10:30:00 11.5 2.2 17.6 6.5 10.8 2.5 17.2 6.1 11.4 2.4 18.3 6.1 335 19 347 165 -9.1 0.1 -8.9 -9.3 03/14/2007 10:40:00 8.5 1.6 12.2 2.6 8.4 1.7 12.2 2.6 7.9 1.5 10.7 3.4 316 22 300 165 -8.8 0.1 -8.3 -9.1 03/14/2007 10:50:00 6.5 1.5 9.9 3.4 6 1.7 10.3 2.6 6 1.2 9.5 3.4 330 24 288 165 -8.3 0.1 -8.1 -8.7 03/14/2007 11:00:00 4.3 1.5 7.2 1.1 4.2 1.6 7.2 0.7 4 1.4 7.2 0.4 336 32 342 165 -9 0 -8.7 -9.3 03/14/2007 11:10:00 5.3 1.8 9.1 1.5 4.7 1.6 8.4 1.5 5.5 1.7 9.5 2.3 17 20 12 165 -8.9 0.4 -8.3 -9.7 03/14/2007 11:20:00 6.5 1.4 9.5 3 6.1 1.7 9.9 2.6 6.4 1.4 9.1 3 357 26 338 165 -8.9 0.4 -8.1 -9.3 03/14/2007 11:30:00 8.3 0.8 10.7 5.7 7.7 1.5 11.1 3.4 8.3 1 11.1 5.3 346 9 341 165 -8.2 0.1 -7.9 -8.5 03/14/2007 11:40:00 9 1.7 13.7 4.6 8.2 2.2 14.5 3.8 9.1 1.8 14.1 5.3 347 13 338 165 -8.5 0.1 -8.1 -8.9 03/14/2007 11:50:00 7.5 1.2 10.7 4.9 6.7 1 9.9 3.8 7.4 1.3 11.1 4.6 345 11 356 165 -8.4 0.2 -8.1 -8.9 03/14/2007 12:00:00 5.5 1 8.8 2.6 5.3 1.1 8.8 2.6 5.4 1 8.4 3 329 15 345 165 -8.9 0.3 -8.5 -9.7 03/14/2007 12:10:00 5.8 0.8 8.4 3 5.6 0.9 8 2.6 5.6 0.9 9.1 3.4 329 20 335 165 -9.2 0.4 -8.5 -9.7 03/14/2007 12:20:00 5.6 1 9.5 3.8 5 1.4 9.9 2.3 5.7 1 9.1 3 347 20 348 165 -8.7 0.3 -8.1 -9.1 03/14/2007 12:30:00 8.8 1.7 13.3 4.6 8.8 1.7 13.7 4.6 9 1.7 13.7 5.7 331 11 355 165 -9 0.3 -8.1 -9.3 03/14/2007 12:40:00 9.1 1.2 13 6.5 9.1 1.2 13 6.1 9.2 1.2 13 6.8 337 8 336 165 -8.9 0 -8.5 -9.3 03/14/2007 12:50:00 9.6 1.2 13.7 6.8 8.8 1.4 12.2 5.7 9.7 1.3 13.3 7.2 342 14 353 165 -9.3 0.1 -8.9 -9.7 03/14/2007 13:00:00 11.2 1.3 14.9 8.8 11 1.9 14.5 6.1 11.1 1.4 14.1 7.2 342 12 330 165 -9.6 0.3 -9.3 -10.2 03/14/2007 13:10:00 10.3 1.2 12.6 6.1 9.2 1.6 13 5.3 10.3 1.3 13.7 6.1 348 12 344 165 -9.9 0.3 -9.3 -10.4 03/14/2007 13:20:00 9.7 1.4 13.3 6.1 9.2 1.5 14.1 4.9 9.6 1.5 13.3 6.1 341 14 356 165 -9.3 0.1 -8.9 -9.7 03/14/2007 13:30:00 11.1 1.8 16.1 6.8 10.8 2.1 16.4 5.7 11.1 2 15.6 6.1 334 16 340 165 -9.3 0 -9.1 -9.7 03/14/2007 13:40:00 10.9 1.7 13.7 5.7 10 2.2 14.5 4.9 10.9 1.6 14.1 6.5 343 15 350 165 -9.2 0.1 -8.9 -9.7 03/14/2007 13:50:00 10.1 1.3 13.7 6.5 9.7 1.7 13.3 4.9 10 1.3 13.3 6.1 338 15 323 165 -9.1 0.1 -8.5 -9.3 03/14/2007 14:00:00 11.2 1.7 16.1 7.6 10.7 1.8 16.4 5.7 11.1 1.9 16.8 7.2 333 15 337 165 -8.7 0.2 -8.1 -9.1 03/14/2007 14:10:00 11.3 2 16.4 6.1 11.2 2 16.4 6.1 11.3 2.2 16.8 5.3 331 13 323 165 -8.8 0.1 -8.5 -9.1 03/14/2007 14:20:00 9.4 1.3 13 6.5 9.3 1.4 13 6.1 9.2 1.5 14.1 6.5 327 13 330 165 -8.9 0.1 -8.5 -9.1 03/14/2007 14:30:00 9.7 1.3 13 5.3 9.6 1.3 13 5.3 9.1 1.3 13 4.6 317 14 321 165 -8.6 0 -8.3 -8.7 03/14/2007 14:40:00 8.3 1.2 11.5 4.6 7.8 1.7 11.1 3 7.9 1.1 11.1 5.3 323 21 317 165 -8.1 0.3 -7.6 -8.5 03/14/2007 14:50:00 10 2 16.1 6.5 9.8 2 16.1 5.7 9.4 2.1 15.6 4.9 325 16 277 165 -7.9 0.1 -7.6 -8.3 03/14/2007 15:00:00 11.7 1.6 16.1 8.4 11.6 1.6 16.4 8.4 11.1 1.7 16.1 7.2 317 18 320 165 -8.6 0.1 -8.3 -8.9 03/14/2007 15:10:00 13.7 2.3 19.9 8.4 13.4 2.5 21 7.2 13.2 2.4 19.9 8 332 16 342 165 -8.5 0.1 -8.3 -8.7 03/14/2007 15:20:00 12.7 2.1 19.5 7.6 11.9 2.1 21 7.6 12.3 2.3 18.3 7.2 335 19 349 165 -8.3 0.2 -8.1 -8.7 03/14/2007 15:30:00 12.9 1.8 17.9 8.4 12.1 2.2 19.1 6.8 12.8 2.1 17.2 7.6 338 15 339 165 -8.5 0.1 -8.3 -8.7 03/14/2007 15:40:00 13.8 1.9 19.5 9.1 13.4 2.1 20.2 8.8 13.7 2 19.5 8.8 333 16 348 165 -8.7 0 -8.5 -8.9 03/14/2007 15:50:00 11.8 2.4 17.9 6.8 11.6 2.4 17.9 5.7 11.8 2.5 19.1 5.7 331 13 348 165 -8.8 0.1 -8.5 -9.1 03/14/2007 16:00:00 8.6 1.4 13.3 5.3 8.5 1.4 13.3 4.6 8.2 1.2 12.6 5.7 322 17 286 165 -8.2 0.1 -8.1 -8.5 03/14/2007 16:10:00 11.1 1.7 14.5 6.5 11 1.8 14.9 5.7 10.8 2.1 14.5 4.9 326 18 328 165 -8.4 0.2 -8.1 -8.7 03/14/2007 16:20:00 9.9 1.3 14.5 7.6 9.9 1.5 15.3 7.2 9.7 1.4 13.7 5.7 320 17 316 165 -8.7 0 -8.5 -8.9 03/14/2007 16:30:00 10.7 1.7 14.9 6.1 10.4 2 14.9 5.3 10.5 1.8 14.9 6.5 331 18 330 165 -8.8 0.2 -8.3 -9.1 03/14/2007 16:40:00 10.9 1.4 15.3 7.6 10.6 1.7 15.3 5.3 10.8 1.5 15.3 7.2 338 12 335 165 -8.7 0.2 -8.3 -8.9 03/14/2007 16:50:00 11.2 1.3 15.3 7.2 11.2 1.5 16.1 4.9 11.3 1.3 15.6 7.6 335 13 339 165 -9 0 -8.9 -9.1 03/14/2007 17:00:00 9.9 1.7 14.5 6.8 9.8 1.7 13.7 6.8 8.8 1.2 11.8 6.5 310 15 294 165 -8.9 0.1 -8.5 -9.3 03/14/2007 17:10:00 8.2 1.2 11.8 5.3 8.1 1.1 11.5 5.3 7.9 1 10.7 5.7 316 12 301 165 -8.8 0.2 -8.5 -9.1 03/14/2007 17:20:00 7.1 1 10.3 4.9 6.6 1.2 9.9 2.6 7.1 1.1 11.1 4.6 342 16 349 165 -8.8 0.2 -8.5 -9.1 03/14/2007 17:30:00 6.9 1.1 10.3 4.6 6.7 1.2 10.3 4.2 6.5 1.1 10.3 4.2 324 15 308 165 -9 0.4 -8.3 -9.7 03/14/2007 17:40:00 8.9 1.7 13 4.6 8.8 1.8 13 4.6 8.7 1.7 14.1 4.6 331 10 330 165 -9.3 0.3 -8.7 -10 03/14/2007 17:50:00 10.4 1 13.3 7.6 10 1.4 13.7 4.6 10 1 13 7.6 338 12 339 165 -10.4 0.3 -10 -10.8 03/14/2007 18:00:00 8.9 1 11.8 6.5 8.9 1.1 11.5 6.5 8.7 1.1 11.5 6.1 336 11 325 165 -10.9 0 -10.6 -11 03/14/2007 18:10:00 9.1 1.6 12.6 4.9 8.3 2 13 3.8 9.4 1.5 13 5.7 346 10 344 165 -10.9 0 -10.8 -11.4 03/14/2007 18:20:00 9.2 1.5 12.6 5.3 9.1 1.7 12.2 4.6 9.1 1.6 13 4.9 335 10 324 165 -11.2 0.1 -11 -11.4 03/14/2007 18:30:00 8 0.9 10.7 6.1 7.7 1.2 10.7 3.8 7.8 0.8 10.3 6.1 334 13 330 165 -11.4 0 -11.4 -11.4 03/14/2007 18:40:00 9.3 1.1 13.3 5.7 9.4 1.1 13 6.1 9.1 1.3 13 5.3 332 13 327 165 -11.5 0 -11.4 -11.8 03/14/2007 18:50:00 10.7 1.1 13.7 7.2 10.7 1.1 13.7 7.2 10.5 1.2 13.3 6.8 331 11 336 165 -11.7 0 -11.6 -12 03/14/2007 19:00:00 11.3 2.5 17.2 6.5 11.1 2.6 17.6 6.1 11.5 2.6 16.8 6.5 335 12 340 165 -11.8 0 -11.6 -12 03/14/2007 19:10:00 9.9 1.3 13.3 6.5 9.6 1.5 13.3 5.7 9.9 1.5 13.7 6.1 334 13 325 165 -11.7 0 -11.6 -12 03/14/2007 19:20:00 8.5 1.2 13 4.9 8.5 1.2 12.6 4.6 7.9 1.3 12.2 4.6 305 15 273 165 -11.6 0 -11.4 -12 03/14/2007 19:30:00 6.5 0.9 9.1 4.2 6.2 1.1 9.1 3.4 6.2 0.8 8.4 4.2 332 20 302 165 -11.6 0 -11.4 -11.8 03/14/2007 19:40:00 6.8 1 10.7 4.6 6.4 1 8.8 3.4 6.8 1 10.3 4.9 345 8 2 165 -11.9 0 -11.8 -12 03/14/2007 19:50:00 9.6 1.7 14.5 5.3 9.6 1.7 14.1 5.3 9.3 1.6 13 5.3 321 18 265 165 -11.9 0 -11.8 -12 03/14/2007 20:00:00 10.5 1.5 14.5 7.6 10.4 1.5 15.3 7.2 10.3 1.6 16.1 6.5 322 16 319 165 -11.9 0 -11.8 -12 03/14/2007 20:10:00 9.3 1.5 15.3 5.7 9.2 1.5 15.3 6.1 8.6 1.7 12.2 4.9 318 18 295 165 -11.9 0 -11.8 -12 03/14/2007 20:20:00 9.2 1.5 13.3 5.3 9 1.5 13.7 5.7 9 1.7 13.7 4.9 334 17 331 165 -11.9 0 -11.8 -12 03/14/2007 20:30:00 8.6 1.3 13.3 5.3 8.6 1.3 13.7 5.3 8.1 1.2 13 5.3 315 15 312 165 -12 0 -11.8 -12.4 03/14/2007 20:40:00 7.3 1.2 10.7 4.2 7.1 1.3 10.3 3.8 6.7 1.4 9.5 3.4 333 16 311 165 -12.1 0 -12 -12.2 03/14/2007 20:50:00 7.6 1.4 12.2 3.8 7.4 1.7 12.2 3 7.2 1.4 11.8 3.8 336 17 322 165 -12.3 0 -12.2 -12.6 03/14/2007 21:00:00 6.6 1 9.1 4.2 6.4 1.2 9.5 3 6.1 1.2 9.1 3.8 329 19 304 165 -12.3 0 -12.2 -12.6 03/14/2007 21:10:00 7.1 1.2 10.3 3.8 6.5 1.5 10.3 3 6.5 1.4 9.5 3 347 11 351 165 -12.3 0 -12.2 -12.6 03/14/2007 21:20:00 6.1 1 8.4 2.3 5.6 1.1 8.4 3 5.9 1 8 3.8 339 16 345 165 -12.1 0 -12 -12.6 03/14/2007 21:30:00 7.8 1 10.3 5.3 7.5 1.3 10.7 4.2 7.6 1 10.7 4.6 339 10 332 165 -12.1 0 -12 -12.4 03/14/2007 21:40:00 7.1 1.3 11.1 4.2 6.9 1.6 11.1 3 6.9 1.5 12.6 3.8 338 15 346 165 -12.1 0 -12 -12.4 03/14/2007 21:50:00 6 1.1 9.1 3.4 6 1.1 9.1 3.8 5.9 1.2 9.5 3 324 15 325 165 -12.1 0 -12 -12.4 03/14/2007 22:00:00 8 1 11.5 6.1 7.9 1 10.7 6.1 7.2 0.9 10.3 4.9 306 12 281 165 -12.1 0 -11.8 -12.4 03/14/2007 22:10:00 7.5 1.3 10.7 4.6 7.4 1.3 10.3 4.6 6.9 1.2 10.3 4.2 316 13 297 165 -12.2 0 -12 -12.4 03/14/2007 22:20:00 4.7 1.2 8 0.7 4.6 1.2 7.6 0.4 3.8 1.1 7.2 0.4 311 22 300 165 -12.4 0 -12.2 -12.6 03/14/2007 22:30:00 5.1 1.1 7.6 2.3 5.1 1.1 8 2.6 4.9 1 8 2.6 322 17 317 165 -12.3 0 -12.2 -12.6 03/14/2007 22:40:00 5.8 0.9 7.6 3.4 5.5 0.9 7.6 3 5.6 0.9 8 3.4 337 13 351 165 -12.4 0 -12.2 -12.6 03/14/2007 22:50:00 6.9 1 9.9 4.9 6.9 1 9.5 4.9 6.8 1 10.7 4.9 321 10 325 165 -12.5 0 -12.4 -12.8 03/14/2007 23:00:00 6 0.8 8.8 4.2 6 0.8 8.8 3.8 5.7 0.8 8.8 4.2 314 9 310 165 -12.8 0 -12.4 -13.2 03/14/2007 23:10:00 7.9 1.3 11.5 5.3 7.9 1.3 11.5 5.3 7.1 0.9 9.9 4.9 309 11 302 165 -12.6 0 -12.4 -13 03/14/2007 23:20:00 8.9 1 11.1 6.5 8.9 1 11.1 6.8 7.6 1.2 10.7 4.9 304 11 301 165 -12.6 0 -12.4 -13.2 03/14/2007 23:30:00 8.4 0.7 10.7 6.5 8.4 0.7 10.7 6.5 6.9 1 9.5 4.9 297 13 275 165 -12.6 0 -12.4 -13 03/14/2007 23:40:00 8.2 1.1 10.3 4.2 8.1 1.1 10.3 3.8 7.2 1 9.9 4.6 305 15 304 165 -12.6 0 -12.4 -12.8 03/14/2007 23:50:00 7.6 1.2 9.9 4.6 7.6 1.2 10.3 4.2 6.4 1.1 9.5 4.2 300 13 302 165 -12.5 0 -12.4 -13 03/15/2007 00:00:00 8.1 1 10.7 5.7 8 1 11.1 5.7 7.1 1.1 10.3 4.6 302 13 286 165 -12.4 0 -12.2 -12.6 03/15/2007 00:10:00 6.3 0.7 8.4 4.6 6.3 0.7 8.4 4.6 6 0.6 7.6 4.9 326 13 307 165 -12.4 0 -12.2 -12.8 03/15/2007 00:20:00 6.4 0.8 9.5 4.2 6.3 0.9 9.1 3.8 6 0.8 8 3.8 318 20 274 165 -12.4 0 -12.4 -12.6 03/15/2007 00:30:00 7.1 1.1 9.5 3.4 7.1 1.1 9.9 4.6 5.8 1.2 9.5 3.4 300 13 300 165 -12.4 0 -12.2 -12.6 03/15/2007 00:40:00 7 1.2 10.7 3.8 6.9 1.2 10.7 3.8 5.9 1.2 8.8 3 303 16 298 165 -12.4 0 -12.2 -12.4 03/15/2007 00:50:00 7.6 1.3 10.7 3 7.6 1.3 9.9 3 6.7 1.5 9.5 2.6 303 19 335 165 -12.3 0 -12.2 -12.6 03/15/2007 01:00:00 8.6 1.7 14.1 5.7 8.4 1.9 13.7 3.8 8.5 1.8 14.1 6.1 326 16 329 165 -12.3 0 -12.2 -12.6 03/15/2007 01:10:00 10 2.4 18.3 5.7 9.7 2.3 18.3 6.1 9.7 2.4 17.6 5.7 330 14 324 165 -12.4 0 -12.2 -12.6 03/15/2007 01:20:00 11.3 1.4 14.9 8 11.2 1.4 14.9 6.1 11.1 1.6 14.9 6.1 326 13 321 165 -12.4 0 -12.2 -12.4 03/15/2007 01:30:00 11.4 1.7 17.2 6.5 11 2.1 17.6 5.7 11.1 1.9 17.2 6.1 330 16 325 165 -12.4 0 -12.2 -12.6 03/15/2007 01:40:00 12 1.9 15.6 6.8 11.9 1.9 15.6 6.5 11.8 2.1 16.4 6.5 325 18 322 165 -12.4 0 -12.2 -12.6 03/15/2007 01:50:00 11.4 2.1 16.8 6.5 11.1 2.4 16.8 6.1 11.2 2.1 17.2 6.1 331 19 335 165 -12.4 0 -12.2 -12.6 03/15/2007 02:00:00 10 1.4 14.5 7.2 9.5 1.7 14.5 5.3 9.8 1.3 13.7 6.8 336 20 347 165 -12.3 0 -12.2 -12.6 03/15/2007 02:10:00 8.4 1.3 11.8 4.9 8.2 1.3 12.2 4.9 8.5 1.5 13 4.9 332 14 356 165 -12.4 0 -12.2 -12.6 03/15/2007 02:20:00 7.6 1.3 12.2 4.2 7.5 1.5 12.6 3.8 7.3 1.7 11.5 4.2 319 18 328 165 -12.4 0 -12.2 -12.6 03/15/2007 02:30:00 8.6 1.7 14.1 5.7 8.1 1.4 12.2 4.9 8.3 2.1 14.5 4.9 326 19 360 165 -12.5 0 -12.4 -12.6 03/15/2007 02:40:00 8.5 1.6 13.3 4.6 7.9 2.1 14.1 3.8 8.3 1.7 14.1 5.3 336 21 341 165 -12.4 0 -12.2 -12.6 03/15/2007 02:50:00 7.6 1.5 11.8 3.8 6.9 1.7 11.1 2.3 7.7 1.5 12.2 3.4 341 16 356 165 -12.4 0 -12.2 -12.6 03/15/2007 03:00:00 5.9 1.2 9.5 1.9 5.7 1.3 9.1 1.9 5.4 1.1 7.6 1.9 313 23 287 165 -12.3 0 -12.2 -12.6 03/15/2007 03:10:00 8.6 1.2 13 5.3 8.6 1.3 13.7 5.7 8 1.5 12.6 4.2 315 21 344 165 -12.4 0 -12.2 -12.6 03/15/2007 03:20:00 7 1.1 10.7 4.6 6.9 1.1 10.3 4.2 6.6 1.1 10.3 4.6 318 17 326 165 -12.6 0 -12.4 -12.6 03/15/2007 03:30:00 6.2 1.1 9.1 4.2 6.2 1.1 9.5 3.8 5.8 1.3 9.5 3 317 20 338 165 -12.5 0 -12.4 -13.2 03/15/2007 03:40:00 5.1 1.2 7.2 1.5 5.1 1.1 7.2 1.9 4.9 1.2 7.2 2.6 317 16 310 165 -12.4 0 -12.2 -12.6 03/15/2007 03:50:00 6.9 1.2 10.7 4.2 6.7 1.3 10.7 4.2 6.9 1.4 11.1 3.8 331 13 317 165 -12.3 0 -12.2 -12.6 03/15/2007 04:00:00 7 1.2 10.3 4.6 6.8 1.3 9.9 3.4 7.3 1.2 10.7 4.9 340 11 350 165 -12.2 0 -12.2 -12.6 03/15/2007 04:10:00 8 2.1 13 3.8 7.9 2.1 13 3.8 7.9 2.1 13.3 3.8 333 12 330 165 -12.3 0 -12.2 -12.6 03/15/2007 04:20:00 9.2 2.3 14.5 4.6 9.2 2.4 14.9 4.6 9.2 2.5 15.6 3.8 328 17 337 165 -12.4 0 -12.2 -12.6 03/15/2007 04:30:00 11.2 1.7 15.6 7.2 11 1.7 16.1 7.2 11.3 1.8 15.6 7.2 327 17 328 165 -12.4 0 -12.2 -12.6 03/15/2007 04:40:00 10.4 3.6 19.1 2.6 9.6 3.5 16.1 3.4 10.4 3.8 21 2.6 333 21 2 165 -12.4 0 -12.2 -12.6 03/15/2007 04:50:00 5.3 1.2 9.1 2.3 5.3 1.2 9.1 2.3 5.1 1.4 8.8 2.3 317 21 333 165 -12.4 0 -12.2 -12.6 03/15/2007 05:00:00 7 1.3 11.1 3.4 6.9 1.3 10.7 3.8 6.9 1.3 11.5 3.4 321 14 315 165 -12.4 0 -12.2 -12.6 03/15/2007 05:10:00 7.5 2.4 13.3 1.5 7.4 2.5 13.7 2.3 7.2 2.1 12.2 3.4 321 22 294 165 -12.4 0 -12.2 -12.6 03/15/2007 05:20:00 7.6 1.7 12.2 3.4 7.5 1.7 12.2 3.8 7.6 1.8 11.8 3.8 324 14 310 165 -12.5 0 -12.2 -12.6 03/15/2007 05:30:00 8.2 1.8 11.8 3.8 8.1 1.8 12.6 3.4 8 2 12.2 3.4 321 17 293 165 -12.5 0 -12.4 -13 03/15/2007 05:40:00 8.2 1.9 13 4.2 8.3 2 13 4.2 8.1 2.1 13 4.2 327 14 332 165 -12.5 0 -12.4 -12.8 03/15/2007 05:50:00 9.8 2.4 17.2 4.6 9.6 2.5 17.6 4.6 9.6 2.3 15.3 4.2 321 16 338 165 -12.4 0 -12.2 -12.6 03/15/2007 06:00:00 10.7 2.5 18.7 6.5 10.4 2.7 17.6 3.8 10.8 2.5 17.9 6.1 330 17 317 165 -12.5 0 -12.4 -12.8 03/15/2007 06:10:00 10.3 1.8 15.3 5.3 10 2.1 15.3 4.2 10.3 1.8 16.1 6.1 327 17 318 165 -12.5 0 -12.4 -12.8 03/15/2007 06:20:00 9.2 1.7 14.1 4.6 9.2 1.7 13.7 4.9 9.2 1.9 14.5 4.6 326 11 317 165 -12.5 0 -12.4 -12.6 03/15/2007 06:30:00 7.4 1.9 14.5 3.4 7.2 1.9 14.1 3.4 7 2 14.1 2.6 317 17 308 165 -12.7 0 -12.6 -13 03/15/2007 06:40:00 7.8 2.1 14.1 3 7.7 2.2 13.7 2.3 7.7 2.2 14.1 3.4 321 18 314 165 -12.7 0 -12.6 -13.2 03/15/2007 06:50:00 6.1 1.4 10.3 2.6 5.9 1.6 10.3 2.3 6 1.5 9.5 2.3 332 18 333 165 -12.8 0.1 -12.6 -13.2 03/15/2007 07:00:00 3.3 1 5.7 1.1 3.4 1 5.7 0.7 3.2 0.9 5.7 1.5 322 22 330 165 -13 0 -12.8 -13.2 03/15/2007 07:10:00 3.8 1.3 6.5 1.1 3.3 1 5.7 1.1 3.6 1.2 6.8 0.7 345 21 360 165 -13.1 0 -13 -13.4 03/15/2007 07:20:00 4.3 1.1 6.8 1.5 3.7 1.1 6.8 0.4 4.3 1.1 6.8 1.9 2 19 25 165 -13.2 0 -13.2 -13.6 03/15/2007 07:30:00 6.3 0.9 8.4 3.8 5.1 1.2 8 2.6 6.3 1 8.8 3.8 6 12 6 165 -13.2 0 -13.2 -13.4 03/15/2007 07:40:00 4.8 1 7.6 2.3 4.3 1 6.8 1.5 4.7 1 8.4 2.3 347 17 13 165 -13.2 0 -13.2 -13.6 03/15/2007 07:50:00 5.6 1.7 9.1 2.3 5.4 1.7 9.1 1.9 5.3 1.7 10.3 2.3 334 29 267 165 -13.1 0 -12.8 -13.6 03/15/2007 08:00:00 8 1.6 12.2 4.2 8 1.6 12.2 3.8 7.6 1.7 11.8 3 314 17 239 165 -12.5 0.1 -12.4 -13 03/15/2007 08:10:00 7.7 2.7 14.9 1.9 7.5 2.8 14.9 1.5 7.4 2.6 14.5 2.3 328 22 312 165 -12.2 0.2 -11.8 -12.6 03/15/2007 08:20:00 8 2.7 15.3 3.4 7.9 2.6 14.9 3.8 7.7 2.7 14.1 2.6 325 15 329 165 -12.2 0.1 -12 -12.4 03/15/2007 08:30:00 12.3 2 17.9 6.8 12.3 2 17.9 6.5 12.4 2 17.6 6.5 325 14 325 165 -12.6 0.1 -12.4 -12.8 03/15/2007 08:40:00 10.6 2 16.4 7.2 10.5 2.1 16.1 5.3 10.6 2.2 16.1 6.8 325 16 328 165 -12.4 0.1 -12.2 -12.6 03/15/2007 08:50:00 12 2.3 18.3 6.5 11.8 2.6 17.2 4.9 12.1 2.6 19.5 5.3 326 20 340 165 -12.5 0.1 -12.2 -12.8 03/15/2007 09:00:00 13.3 2 17.9 7.2 13.2 2.2 18.3 7.2 13.5 2 17.2 8 330 16 349 165 -12.4 0.1 -12.2 -12.6 03/15/2007 09:10:00 11.1 2.4 16.8 5.3 10.9 2.4 17.2 5.3 10.9 2.6 16.8 4.9 324 19 340 165 -12.4 0.2 -12 -12.8 03/15/2007 09:20:00 10.5 2.1 15.3 5.3 10.4 2.1 15.3 5.7 10.5 2.2 16.1 5.3 325 15 323 165 -12 0.2 -11.8 -12.6 03/15/2007 09:30:00 11.7 2.4 18.7 5.7 11.1 2.5 19.1 5.3 11.4 2.6 19.1 6.5 329 20 349 165 -11.9 0 -11.6 -12.2 03/15/2007 09:40:00 10.8 2.2 16.8 6.5 10.7 2.3 17.2 5.7 10.6 2.2 16.8 6.1 322 17 313 165 -11.9 0.1 -11.8 -12.2 03/15/2007 09:50:00 10.4 2.3 16.4 6.1 10.4 2.5 16.4 5.7 10.5 2.5 16.8 5.3 327 18 336 165 -11.7 0.2 -11.4 -12.2 03/15/2007 10:00:00 11.1 2.2 17.9 5.7 10.9 2.4 17.6 4.9 11.1 2.3 17.6 5.7 324 17 321 165 -11.7 0.2 -11.4 -12.2 03/15/2007 10:10:00 11.1 1.8 17.6 7.2 10.7 2.1 17.6 6.8 11 1.8 17.6 6.8 332 18 339 165 -11.6 0 -11.4 -11.8 03/15/2007 10:20:00 9.1 2 14.9 4.6 9 2 14.9 3.4 8.6 1.9 14.5 4.2 309 20 308 165 -11.5 0.1 -11 -11.8 03/15/2007 10:30:00 8.9 1.3 11.8 5.3 8.6 1.5 12.2 4.6 8.6 1.3 12.2 4.9 322 22 5 165 -11.2 0.2 -10.8 -11.6 03/15/2007 10:40:00 10.1 2.8 17.9 5.7 9.7 2.7 17.6 5.3 9.8 2.5 17.6 5.7 331 17 353 165 -11.1 0.2 -10.6 -11.6 03/15/2007 10:50:00 10.2 2 15.3 6.1 10 1.9 16.1 6.5 10.2 2.2 15.3 4.9 326 18 328 165 -11 0.1 -10.6 -11.4 03/15/2007 11:00:00 11.7 2.3 17.9 6.8 10.7 2.3 19.1 5.7 11.8 2.4 17.9 6.5 332 21 346 165 -10.9 0.1 -10.6 -11.4 03/15/2007 11:10:00 12.1 2.8 19.1 6.1 11.7 2.5 17.9 6.1 11.9 2.8 18.3 5.3 328 20 343 165 -11 0.1 -10.8 -11.4 03/15/2007 11:20:00 9.8 1.7 15.3 5.7 9.5 1.7 14.5 5.7 9.5 1.7 14.1 5.3 320 22 317 165 -10.6 0.1 -10.2 -11.2 03/15/2007 11:30:00 10.2 2.3 16.4 4.2 10.1 2.3 16.1 4.2 9.8 2.6 16.8 3.8 312 22 317 165 -10.9 0.2 -10.6 -11.4 03/15/2007 11:40:00 10.4 1.7 14.5 5.7 10.2 1.7 14.9 5.3 9.7 1.9 14.5 5.7 315 26 309 165 -10.9 0.2 -10.6 -11.4 03/15/2007 11:50:00 9.6 1.6 13.3 4.9 9 1.7 13.7 3.8 9 1.8 13.7 4.9 321 26 326 165 -10.4 0.1 -10.2 -11 03/15/2007 12:00:00 9.5 1.8 13.7 4.9 9.3 1.8 13.7 4.9 9.2 1.9 14.1 4.2 317 21 304 165 -10.3 0.2 -10 -10.8 03/15/2007 12:10:00 10.3 1.3 14.1 6.5 10.2 1.3 14.5 6.5 9.5 1.5 14.5 6.5 307 16 316 165 -10.6 0 -10.2 -10.8 03/15/2007 12:20:00 10.8 1.5 16.4 5.7 10.7 1.5 14.9 5.7 9.9 2 16.1 5.3 310 22 319 165 -10.4 0.2 -10 -10.8 03/15/2007 12:30:00 11.2 2.1 16.4 6.5 11.2 2.1 16.4 6.1 11 2.3 16.4 4.9 322 18 325 165 -10.1 0.1 -9.7 -10.6 03/15/2007 12:40:00 9.4 1.6 13 4.6 9.4 1.6 13 4.9 9 1.8 13.3 4.9 312 26 315 165 -10.3 0.1 -10 -10.6 03/15/2007 12:50:00 10.4 1.7 14.9 6.5 10.3 1.7 14.9 6.1 9.8 1.9 15.3 5.3 312 24 341 165 -10.2 0.2 -9.7 -10.6 03/15/2007 13:00:00 10.8 1.5 14.9 6.8 10.7 1.5 14.9 6.8 10.2 1.7 15.3 6.1 310 15 316 165 -10.4 0.2 -10 -10.8 03/15/2007 13:10:00 10.8 2 16.1 6.8 10.6 2.1 15.6 6.8 10.7 2.3 16.1 6.1 321 21 332 165 -10.1 0.3 -9.3 -10.6 03/15/2007 13:20:00 10.4 1.3 14.1 6.5 10.4 1.3 13.7 6.8 9.2 1.2 12.6 6.5 302 22 309 165 -10 0.3 -9.3 -10.6 03/15/2007 13:30:00 11.9 1.6 17.9 7.6 11.8 1.6 17.6 7.6 10.6 1.8 15.3 6.1 298 17 292 165 -10.4 0.1 -10.2 -10.8 03/15/2007 13:40:00 10 1.8 14.5 4.9 9.9 1.8 14.5 5.3 9.6 1.9 14.5 5.7 313 18 275 165 -9.6 0.5 -8.9 -10.6 03/15/2007 13:50:00 9.9 1.7 14.1 5.3 9.7 1.8 13.7 4.9 9.1 1.9 14.1 4.6 313 26 357 165 -8.8 0.2 -8.5 -9.3 03/15/2007 14:00:00 10.4 1.7 14.5 6.8 10.3 1.6 14.5 6.5 10.2 1.5 14.5 7.2 319 18 299 165 -9.3 0.1 -9.1 -9.7 03/15/2007 14:10:00 10.3 2.2 17.2 5.3 10.1 2.2 17.6 5.7 10 2.5 16.8 5.3 319 22 343 165 -9.6 0 -9.3 -9.7 03/15/2007 14:20:00 9.6 1.8 15.3 5.7 9.2 1.8 15.3 4.6 9 2.1 14.9 5.3 320 24 347 165 -9.1 0.3 -8.7 -10.2 03/15/2007 14:30:00 8.3 1.4 12.2 4.6 8.2 1.3 11.8 4.6 7.8 1.4 12.2 4.6 312 19 324 165 -9.1 0.2 -8.7 -9.7 03/15/2007 14:40:00 9 1.8 13.7 5.3 8.9 1.8 13.7 5.3 8.9 1.7 13.7 4.9 325 16 341 165 -9.4 0.1 -9.1 -9.7 03/15/2007 14:50:00 10.1 2.3 14.9 4.6 9.9 2.4 14.9 3.8 10 2.5 14.9 4.2 329 17 336 165 -9.2 0.1 -8.9 -9.3 03/15/2007 15:00:00 11.3 2.3 18.3 5.7 10.9 2.6 17.9 6.1 11.3 2.6 16.4 4.6 330 21 330 165 -9.4 0.2 -8.9 -9.7 03/15/2007 15:10:00 10.2 2.8 16.8 3.8 10.1 2.9 17.9 3.4 10.1 2.9 16.4 3.8 325 19 345 165 -9.1 0.1 -8.9 -9.5 03/15/2007 15:20:00 10.9 2.5 17.6 4.2 10.6 2.5 17.6 3.8 10.6 2.8 16.8 3.8 327 22 293 165 -9.4 0.2 -8.9 -9.7 03/15/2007 15:30:00 8.8 1.8 13.7 4.6 8.5 1.9 14.5 4.2 8.8 1.8 13.7 5.3 329 18 344 165 -9.8 0 -9.7 -10.2 03/15/2007 15:40:00 9.5 2 14.5 4.6 9.1 2.1 15.3 4.6 9.2 2.2 14.9 4.2 327 21 332 165 -9.8 0 -9.5 -10 03/15/2007 15:50:00 9.9 1.6 14.1 4.9 9.7 1.6 14.1 5.3 9.1 1.5 14.1 4.9 316 22 304 165 -10.1 0.1 -9.7 -10.2 03/15/2007 16:00:00 9.2 1.5 13.3 5.7 9.1 1.5 13.7 5.3 8.8 1.5 12.6 4.9 309 22 309 165 -10 0.1 -9.7 -10.4 03/15/2007 16:10:00 11 2.2 19.1 6.5 10.9 2.2 19.1 6.1 10.5 2.3 18.3 5.3 313 21 289 165 -9.8 0 -9.5 -10.2 03/15/2007 16:20:00 10.3 2.2 17.9 6.1 10.2 2.2 18.3 6.1 9.5 2.4 17.6 5.3 310 20 337 165 -9.7 0.1 -9.5 -10.2 03/15/2007 16:30:00 9.1 1.3 13 4.2 8.8 1.4 12.6 4.9 8.2 1.5 13.7 4.2 313 23 325 165 -9.5 0 -9.3 -9.7 03/15/2007 16:40:00 8.3 2.2 14.1 4.2 8.1 2.2 14.1 3.8 7.7 2 12.2 3.8 323 21 334 165 -9.5 0.1 -9.3 -9.7 03/15/2007 16:50:00 10.8 2.2 16.4 6.1 10.4 2.4 16.4 4.2 10.6 2.2 16.8 5.3 333 17 338 165 -10 0.1 -9.7 -10.2 03/15/2007 17:00:00 10.4 2.4 16.8 5.7 10 2.6 17.2 4.6 10.3 2.5 17.2 6.1 329 21 334 165 -10.2 0 -10 -10.4 03/15/2007 17:10:00 10.6 2.1 17.6 5.3 10.4 2.1 15.6 4.6 10.3 2.4 18.3 5.7 325 21 347 165 -10 0.1 -9.7 -10.2 03/15/2007 17:20:00 11.3 2.1 17.6 7.2 11.2 2.1 17.2 6.8 11.1 2.1 17.2 6.1 322 20 253 165 -10.4 0 -10.2 -10.8 03/15/2007 17:30:00 9.2 1.5 13.7 4.6 9.1 1.5 13.3 4.2 8.8 1.4 13 4.9 316 18 316 165 -10.5 0 -10.4 -11 03/15/2007 17:40:00 8.8 1.5 14.1 5.7 8.7 1.5 13.7 5.7 8.3 1.5 13 4.6 316 17 334 165 -10.2 0.1 -9.7 -10.6 03/15/2007 17:50:00 8.3 1.5 13 5.3 8.2 1.5 12.6 4.9 7.3 1.5 11.5 3.8 306 19 309 165 -10.2 0.2 -9.7 -10.6 03/15/2007 18:00:00 9.4 2 16.1 5.3 9.3 1.9 15.6 5.3 8.2 1.7 13.3 4.9 302 18 256 165 -10.5 0 -10.4 -10.8 03/15/2007 18:10:00 11.3 1.9 15.6 6.1 11.3 1.8 16.1 6.1 9.2 1.5 14.1 6.1 291 15 301 165 -10.8 0.1 -10.6 -11 03/15/2007 18:20:00 11.6 1.7 16.8 6.5 11.5 1.7 16.4 6.5 9.4 1.6 16.4 4.6 294 13 315 165 -10.9 0 -10.8 -11.2 03/15/2007 18:30:00 13.1 1.9 17.9 7.2 13.1 1.9 18.3 6.8 10.2 1.7 16.8 4.9 288 17 298 165 -10.9 0 -10.8 -11.2 03/15/2007 18:40:00 13.4 1.7 17.9 9.5 13.4 1.7 17.9 9.1 10.7 1.7 17.6 7.2 290 15 297 165 -11 0 -11 -11.4 03/15/2007 18:50:00 13.4 1.7 18.7 9.1 13.4 1.7 17.9 9.1 10.5 1.7 17.2 7.2 293 16 292 165 -11 0 -10.8 -11.4 03/15/2007 19:00:00 13.6 1.7 18.7 9.9 13.6 1.7 18.3 9.5 10.8 1.8 16.1 7.6 285 19 307 165 -11 0 -11 -11.4 03/15/2007 19:10:00 15.2 2.1 21.4 8 15.2 2.1 21.4 8.4 12 2 19.1 6.8 285 14 230 165 -11.2 0 -11 -11.4 03/15/2007 19:20:00 16.5 2.5 22.9 10.7 16.5 2.5 22.9 9.9 12.4 2 18.7 7.2 288 16 300 165 -11.3 0 -11 -11.4 03/15/2007 19:30:00 15.7 2.2 21 9.5 15.7 2.3 21 9.5 11.9 1.7 16.8 7.6 283 17 282 165 -11.3 0 -11.2 -11.4 03/15/2007 19:40:00 13.6 1.9 19.5 6.5 13.6 1.9 19.5 6.5 12 2.1 17.6 6.1 278 18 266 165 -11.3 0 -11.2 -11.4 03/15/2007 19:50:00 15.9 2.8 21.8 9.5 15.9 2.8 21.8 8.8 12.6 2.4 19.9 6.8 286 19 300 165 -11.3 0 -11 -11.8 03/15/2007 20:00:00 16.6 1.5 19.9 11.5 16.7 1.6 19.9 11.5 12.5 1.6 17.6 9.1 287 17 298 165 -11.2 0 -11 -11.6 03/15/2007 20:10:00 15.8 2 19.5 9.5 15.8 2.1 19.9 9.5 12 1.7 17.9 8 284 19 282 165 -11.2 0 -11 -11.4 03/15/2007 20:20:00 13.1 1.5 17.2 9.5 13 1.6 16.8 9.5 11.1 2.2 16.8 6.5 276 17 264 165 -11.4 0 -11.2 -11.6 03/15/2007 20:30:00 14.6 1.7 19.5 11.1 14.5 1.7 19.1 11.1 12.3 2 17.9 8 278 17 297 165 -11.4 0 -11.4 -11.6 03/15/2007 20:40:00 14.9 2 20.2 9.5 14.9 2 20.2 9.9 12.7 2 18.7 6.5 276 18 287 165 -11.3 0 -11.2 -11.6 03/15/2007 20:50:00 11.4 2.7 17.2 3.4 11.4 2.6 17.2 3.4 8.6 2.8 14.1 2.3 277 19 286 165 -11.3 0 -11.4 -11.6 03/15/2007 21:00:00 15.7 2.9 21.4 9.5 15.5 2.9 21.8 9.9 12.9 3.1 20.2 6.1 276 18 287 165 -11.2 0 -11 -11.4 03/15/2007 21:10:00 19 2.2 24 11.8 18.9 2.2 24 11.8 15.6 2.5 22.1 9.9 278 16 235 165 -11.2 0 -11 -11.4 03/15/2007 21:20:00 20 1.9 23.3 13.7 20 2 23.7 13.7 15.7 2.4 22.9 9.9 277 20 271 165 -11.1 0 -11 -11.4 03/15/2007 21:30:00 20 1.9 24.4 15.3 20 2 24.4 15.3 15.7 2.2 22.9 11.5 277 19 288 165 -11.1 0 -11 -11.4 03/15/2007 21:40:00 20.2 2 24.8 14.9 20.2 2.1 24.8 14.5 16.7 2.5 23.3 10.7 277 19 241 165 -11.1 0 -11 -11.4 03/15/2007 21:50:00 20.4 1.9 24 14.5 20.5 2 24.4 14.1 15.8 2.1 22.9 11.5 278 18 289 165 -11 0 -10.8 -11.4 03/15/2007 22:00:00 20.3 2.2 26 14.5 20.4 2.3 26.3 14.5 15.2 2.3 21.8 10.3 281 21 293 165 -10.9 0 -10.8 -11.4 03/15/2007 22:10:00 19.6 2.6 25.2 10.3 19.6 2.8 26 10.3 14.8 2.3 21 8.4 279 21 254 165 -10.9 0 -10.8 -11.2 03/15/2007 22:20:00 17.1 2.2 21 9.9 17 2.3 21.8 9.5 13.7 1.9 18.3 7.2 286 19 275 165 -10.9 0 -10.8 -11.4 03/15/2007 22:30:00 17.3 2.5 23.3 10.3 17.3 2.6 24.4 10.3 14.3 2.6 20.6 8.4 288 21 256 165 -10.8 0.1 -10.6 -11.4 03/15/2007 22:40:00 19.8 2.2 24.8 13.3 19.8 2.3 24.8 13.3 16.7 1.8 23.3 12.2 288 20 308 165 -10.7 0 -10.6 -10.8 03/15/2007 22:50:00 17 2.2 23.7 11.5 16.9 2.2 24.4 11.5 14.5 2.5 21 7.6 290 22 288 165 -10.6 0.2 -10.2 -11 03/15/2007 23:00:00 17.1 2.7 24 7.6 17 2.7 24.4 7.6 15.1 3.1 23.7 7.6 298 19 287 165 -9.9 0.2 -9.3 -10.4 03/15/2007 23:10:00 17.7 2 22.6 11.5 17.6 2 22.6 11.8 14.5 2.2 20.2 9.1 288 20 287 165 -10 0.4 -9.1 -10.6 03/15/2007 23:20:00 14.8 3.3 21.8 6.8 14.7 3.3 21.8 7.2 11 3.3 17.9 2.3 284 21 302 165 -10.5 0 -10.4 -10.8 03/15/2007 23:30:00 11.4 3.1 17.9 2.6 11.3 3.1 18.3 1.5 8.5 3.2 16.4 1.1 295 24 241 165 -10.4 0 -10.2 -10.8 03/15/2007 23:40:00 10.7 2.4 16.8 4.6 10.6 2.5 16.8 4.2 8 2.6 14.5 1.5 292 26 301 165 -10.2 0 -10.2 -10.4 03/15/2007 23:50:00 9.9 2.3 17.6 3.8 9.8 2.3 17.2 4.9 8.1 2.1 14.5 2.6 303 22 273 165 -10.2 0 -10 -10.4 03/16/2007 00:00:00 11.5 2.8 18.3 5.3 11.1 2.6 17.9 5.3 10.6 2.8 17.9 5.3 324 23 354 165 -9.9 0 -9.7 -10.2 03/16/2007 00:10:00 10.3 2 16.4 5.3 10.1 2 16.8 5.3 9.1 1.9 15.3 5.3 317 24 253 165 -9.9 0 -9.7 -10.2 03/16/2007 00:20:00 12.4 2.1 17.9 6.5 12.2 2.1 17.6 6.5 11.2 2.1 17.2 6.5 315 22 318 165 -9.8 0 -9.7 -10.2 03/16/2007 00:30:00 13.5 2.1 19.5 7.6 13.5 2 19.5 8 11.5 2.2 17.2 4.2 294 22 300 165 -9.7 0 -9.7 -10.2 03/16/2007 00:40:00 14.8 2.2 20.6 6.5 14.7 2.2 21 6.8 11.8 2.2 17.9 4.9 291 22 293 165 -9.9 0.1 -9.5 -10.2 03/16/2007 00:50:00 14.5 2 19.9 9.5 14.4 2 19.5 9.5 12 2.3 17.6 4.6 290 23 241 165 -9.7 0 -9.5 -10.2 03/16/2007 01:00:00 12.7 2.2 19.1 7.6 12.6 2.3 19.1 7.2 10.7 2 16.8 5.3 297 27 303 165 -9.8 0.1 -9.3 -10.2 03/16/2007 01:10:00 11.6 1.6 15.6 7.2 11.5 1.6 16.4 7.2 10.5 1.7 14.9 5.7 312 24 340 165 -9.4 0 -9.3 -9.7 03/16/2007 01:20:00 13.4 2.4 20.6 7.2 13 2.3 20.6 7.2 12.5 2.3 19.5 6.8 323 22 351 165 -9.2 0 -9.1 -9.7 03/16/2007 01:30:00 13.1 1.8 18.3 8 12.9 1.9 18.3 7.6 12.5 1.8 18.7 7.2 321 23 339 165 -9.2 0 -9.1 -9.7 03/16/2007 01:40:00 16.8 2.1 25.6 12.2 16.5 2.1 25.2 12.2 16.2 2.2 22.9 10.7 326 22 335 165 -9.1 0 -8.9 -9.3 03/16/2007 01:50:00 15.2 2.3 21 9.5 15 2.3 21.4 9.5 14.6 2.3 20.2 8.4 323 22 342 165 -9 0 -8.9 -9.1 03/16/2007 02:00:00 14.9 1.5 18.3 8.8 14.6 1.5 18.7 9.5 14.2 1.5 18.7 9.9 316 22 305 165 -9.1 0 -8.9 -9.3 03/16/2007 02:10:00 15.7 1.5 19.5 11.1 15.5 1.5 19.5 11.5 14.5 1.9 19.1 9.1 304 22 307 165 -9.3 0 -8.9 -9.5 03/16/2007 02:20:00 16.1 2.1 20.6 8.4 15.9 2.1 20.6 9.1 14.4 2.3 19.9 8.4 301 22 315 165 -9.5 0 -9.3 -9.7 03/16/2007 02:30:00 15.9 2.1 20.6 9.1 15.7 2.1 20.2 9.5 13.3 2.9 20.2 2.6 293 22 309 165 -9.4 0 -9.3 -9.7 03/16/2007 02:40:00 14.3 2.5 20.6 7.6 13.9 2.4 19.5 8 12.6 2.7 18.3 4.2 318 29 351 165 -9.2 0.2 -8.7 -9.7 03/16/2007 02:50:00 15.1 1.7 19.1 10.7 14.6 2 19.5 8.4 14 2 20.2 8.8 333 20 326 165 -8.7 0 -8.5 -9.1 03/16/2007 03:00:00 14.8 1.8 19.5 9.5 14.1 2 19.9 9.1 13.9 2 20.2 6.8 334 21 328 165 -8.6 0 -8.5 -8.9 03/16/2007 03:10:00 13.8 2.2 19.1 7.6 13.4 2.2 17.9 7.6 12.8 2.1 19.1 8 328 22 325 165 -8.6 0 -8.5 -8.9 03/16/2007 03:20:00 13.7 1.7 17.9 9.1 13.3 1.8 17.2 8 12.6 1.8 17.6 8 325 23 329 165 -8.7 0 -8.5 -8.9 03/16/2007 03:30:00 13.3 2.1 17.9 6.5 13.2 2.2 19.1 6.1 11 2.1 16.1 4.2 298 23 286 165 -8.9 0 -8.5 -9.1 03/16/2007 03:40:00 12.7 2.3 19.1 7.2 12.1 2.1 18.7 7.6 11.9 2.5 18.3 7.2 329 22 355 165 -9 0 -8.7 -9.3 03/16/2007 03:50:00 16.3 2.4 21.8 9.1 15.9 2.6 22.1 8 15.1 2.7 21 6.5 332 22 345 165 -8.8 0 -8.7 -9.1 03/16/2007 04:00:00 12 1.5 15.6 7.2 11.8 1.5 15.3 7.2 11.2 1.5 15.3 6.5 315 23 316 165 -9 0 -8.7 -9.1 03/16/2007 04:10:00 11.5 1.7 16.1 7.2 11.3 1.7 15.6 6.8 10.8 1.6 15.6 7.2 318 21 288 165 -9.1 0 -8.9 -9.3 03/16/2007 04:20:00 14.9 2.7 21 9.1 14.2 2.9 21.8 9.1 13.8 2.8 21 8 334 21 291 165 -8.9 0.1 -8.7 -9.1 03/16/2007 04:30:00 16.6 2.4 21.8 9.1 15.6 2.8 21.8 8.4 16 2.6 21.8 9.5 335 20 307 165 -8.5 0 -8.3 -8.7 03/16/2007 04:40:00 14.7 1.9 20.2 9.5 14.1 1.8 19.5 9.1 13.8 2.2 21.4 8.8 328 22 314 165 -8.5 0 -8.3 -8.7 03/16/2007 04:50:00 13.1 2.2 20.2 8.4 12.9 2.1 20.6 8 12.1 2.1 19.9 8 314 22 328 165 -8.8 0 -8.3 -8.9 03/16/2007 05:00:00 15.6 2.1 21 11.1 15.1 2.2 21.4 9.5 14.9 2.2 22.9 9.9 331 20 271 165 -8.7 0.1 -8.3 -8.9 03/16/2007 05:10:00 14.5 2.2 21.4 9.1 13.9 2.2 19.5 8 13.6 2.3 21.8 7.6 331 22 355 165 -8.5 0 -8.3 -8.7 03/16/2007 05:20:00 14.4 2.1 21 9.1 13.9 2.5 22.1 6.1 13.4 2.2 19.9 7.2 331 22 344 165 -8.4 0 -8.1 -8.7 03/16/2007 05:30:00 10.8 2.2 18.7 6.1 10.5 2.2 18.7 5.7 9.5 2.3 17.2 3.4 324 24 339 165 -8.6 0.1 -8.3 -8.7 03/16/2007 05:40:00 10 2.4 16.8 2.6 9.9 2.4 17.2 3 8.2 2.4 17.6 1.5 316 23 343 165 -8.6 0 -8.5 -8.9 03/16/2007 05:50:00 10.7 2.4 17.2 4.9 10.4 2.4 17.2 4.2 8.5 2.6 16.4 1.1 317 26 309 165 -8.9 0 -8.5 -9.1 03/16/2007 06:00:00 12.6 2.4 19.1 5.7 12.3 2.4 18.7 5.7 10.9 2.6 18.7 2.6 325 23 295 165 -8.5 0 -8.3 -8.9 03/16/2007 06:10:00 11 2.5 17.6 3 10.9 2.4 17.6 3.4 9.5 2.8 16.8 2.3 307 24 330 165 -8.7 0 -8.5 -8.9 03/16/2007 06:20:00 10.5 2 17.2 3.8 10.4 2.1 17.2 4.9 8.3 2.3 13.3 1.9 304 26 280 165 -8.9 0 -8.7 -9.3 03/16/2007 06:30:00 11.9 2.5 17.6 4.6 11.8 2.4 17.6 4.9 9.9 2.6 16.8 3.8 307 27 332 165 -9.1 0 -8.9 -9.3 03/16/2007 06:40:00 13.2 2 18.7 6.5 13 2 19.1 6.5 11.4 2.1 16.4 5.3 309 24 270 165 -8.8 0.1 -8.5 -9.1 03/16/2007 06:50:00 15.1 2.3 21.4 8.8 14.9 2.3 21.4 8.8 14 2.6 20.6 7.2 313 24 244 165 -8.7 0.1 -8.5 -9.1 03/16/2007 07:00:00 18.1 2.2 24.4 11.5 17.9 2.2 24.4 11.8 16.8 2.1 21.8 11.5 303 22 281 165 -8.8 0.1 -8.3 -9.1 03/16/2007 07:10:00 16.2 2.5 21.8 10.7 16.1 2.5 21.8 11.1 14.3 2.7 22.1 7.6 302 23 301 165 -8.9 0 -8.7 -9.1 03/16/2007 07:20:00 12.7 2.2 17.6 7.6 12.5 2.2 17.6 7.6 11.3 2.2 17.9 6.1 323 22 295 165 -8.8 0.1 -8.5 -9.3 03/16/2007 07:30:00 16.5 2 21.8 11.1 15.5 2.2 21 10.3 15.2 2.3 20.6 9.5 335 18 350 165 -8.5 0 -8.3 -8.9 03/16/2007 07:40:00 14.3 2 20.6 9.9 14 2.1 21.4 9.1 13.3 2 19.1 8 325 26 277 165 -8.5 0 -8.3 -8.9 03/16/2007 07:50:00 14.2 2.1 19.1 8 14 2.1 19.5 8 13.1 1.9 18.7 8.4 311 20 300 165 -8.4 0 -8.3 -8.9 03/16/2007 08:00:00 15 2 21 9.9 14.8 2 20.6 9.9 14 2.2 20.2 9.1 311 23 332 165 -8.2 0 -8.1 -8.5 03/16/2007 08:10:00 16.9 2.5 24 9.5 16.8 2.5 23.7 9.5 13.6 2.3 19.1 6.8 287 21 238 165 -8.2 0 -8.1 -8.7 03/16/2007 08:20:00 15.2 2.8 21 9.1 15.1 2.8 21 9.1 13.4 3.2 21 5.3 301 22 272 165 -8 0.1 -7.6 -8.5 03/16/2007 08:30:00 18 1.7 24 14.1 17.7 1.7 23.7 14.1 17.2 1.9 22.6 13 305 19 317 165 -8.1 0.1 -7.9 -8.5 03/16/2007 08:40:00 15.9 2.2 20.6 10.3 15.8 2.2 21 10.7 13.6 2.4 19.1 8.4 292 21 305 165 -8.4 0.1 -8.1 -8.5 03/16/2007 08:50:00 15.9 2 21 10.3 15.8 1.9 21 10.3 13.4 2.2 19.1 6.5 293 20 300 165 -8.4 0 -8.1 -8.5 03/16/2007 09:00:00 17.1 2.3 22.9 11.5 16.9 2.2 22.6 11.8 14.7 2.4 20.6 6.5 295 19 288 165 -8.1 0 -8.1 -8.5 03/16/2007 09:10:00 15.8 1.7 19.9 10.3 15.6 1.8 19.5 9.9 14 2 19.1 9.1 299 21 313 165 -8 0 -7.9 -8.3 03/16/2007 09:20:00 17.8 2 23.7 11.5 17.7 2.1 23.3 11.5 15.9 2.2 20.6 9.5 296 16 286 165 -8.1 0 -8.1 -8.3 03/16/2007 09:30:00 20.1 2 26.3 14.9 20 2 26 15.3 17.4 2 22.9 10.3 288 18 285 165 -8.3 0 -8.1 -8.5 03/16/2007 09:40:00 21.2 2.3 26.8 13.7 21.1 2.3 26 13.3 17.5 2.4 24.8 9.5 284 20 284 165 -8.5 0.1 -8.1 -8.9 03/16/2007 09:50:00 21 2 24.4 14.9 21 2 24.8 14.5 17.3 1.7 22.9 12.2 284 21 272 165 -8.8 0 -8.7 -8.9 03/16/2007 10:00:00 21.5 1.8 26.3 14.5 21.4 1.8 26 14.5 17.3 2 23.3 11.8 286 17 292 165 -8.6 0.1 -8.3 -8.9 03/16/2007 10:10:00 21.1 2.1 25.6 15.3 21 2.1 25.6 15.3 16.9 2 21.4 10.3 285 17 294 165 -8.3 0 -8.3 -8.5 03/16/2007 10:20:00 22.5 1.6 27.5 17.2 22.5 1.6 27.1 16.4 17.3 1.9 24.4 12.6 286 14 279 165 -8.2 0 -8.1 -8.5 03/16/2007 10:30:00 22.5 1.8 26.3 16.4 22.5 1.9 26.3 16.1 17.3 1.8 21.8 11.8 286 17 285 165 -8.1 0 -8.1 -8.3 03/16/2007 10:40:00 22.4 1.8 26 17.2 22.5 1.8 25.6 17.2 17.1 2 25.6 12.6 286 14 290 165 -8.2 0 -8.1 -8.3 03/16/2007 10:50:00 22.5 2.1 28.7 16.8 22.6 2.1 28.3 16.8 17 2.4 26.8 12.2 285 14 294 165 -8 0 -7.6 -8.1 03/16/2007 11:00:00 23 1.7 26 17.9 23.1 1.7 26 18.3 17.2 1.7 22.6 13.3 285 15 293 165 -7.7 0 -7.6 -7.9 03/16/2007 11:10:00 21.6 1.9 26 14.9 21.6 1.9 26.3 14.5 16.9 2.2 22.9 11.5 287 18 299 165 -7.5 0.1 -7.2 -7.9 03/16/2007 11:20:00 21 2.2 26 16.1 21 2.2 26 16.4 17.5 2.2 23.3 11.5 288 17 293 165 -7.3 0 -7 -7.4 03/16/2007 11:30:00 21.2 1.8 25.6 14.9 21.1 1.8 26 14.9 17.8 2 23.7 12.2 292 15 296 165 -6.9 0 -6.8 -7.2 03/16/2007 11:40:00 19.6 1.9 24.8 14.9 19.5 2 24.8 14.9 17.3 2.3 24 11.5 292 17 236 165 -6.7 0 -6.6 -7 03/16/2007 11:50:00 20.3 1.9 24 14.9 20.3 2 24 14.5 16.3 1.8 21.8 11.8 288 18 300 165 -6.5 0 -6.4 -6.8 03/16/2007 12:00:00 20.4 1.7 23.7 15.6 20.3 1.7 24 15.6 15.8 1.8 21.4 11.8 288 18 292 165 -6.4 0 -6.1 -6.6 03/16/2007 12:10:00 20.3 1.8 23.7 15.3 20.3 1.8 24 14.9 17.1 2.2 22.6 11.5 288 20 302 165 -6.1 0 -5.7 -6.6 03/16/2007 12:20:00 20 1.8 24 14.1 19.9 1.8 24 14.5 16.8 2 22.1 11.5 287 21 301 165 -5.9 0 -5.7 -6.4 03/16/2007 12:30:00 20.3 1.9 24 14.9 20.2 1.9 24 14.5 17.7 2 24.4 12.2 291 21 301 165 -5.9 0 -5.7 -6.1 03/16/2007 12:40:00 21.6 1.6 25.6 16.4 21.4 1.6 25.6 16.1 19 2 23.3 13.7 294 18 257 165 -5.9 0 -5.7 -6.1 03/16/2007 12:50:00 21 1.7 24.8 16.1 20.9 1.8 24.8 15.3 19.2 2 23.3 13 292 21 298 165 -5.9 0 -5.7 -6.1 03/16/2007 13:00:00 19.9 1.7 23.7 15.3 19.8 1.7 23.7 15.3 18.1 2 23.7 11.8 294 20 304 165 -5.8 0 -5.5 -6.4 03/16/2007 13:10:00 21.2 1.8 24.4 15.3 21.1 1.9 24.4 15.6 19 2 23.7 12.6 294 17 307 165 -5.6 0 -5.5 -5.7 03/16/2007 13:20:00 22.6 1.5 25.2 17.9 22.5 1.5 25.2 17.9 19.9 1.7 24 15.3 293 18 274 165 -5.5 0 -5.3 -5.7 03/16/2007 13:30:00 22.6 1.7 26.3 17.9 22.5 1.8 26 18.3 21.4 1.7 24.8 16.4 296 17 305 165 -5.3 0 -5.3 -5.7 03/16/2007 13:40:00 22.5 1.8 25.2 17.2 22.4 1.9 25.2 16.8 21.2 2.3 25.2 13.3 298 15 284 165 -5.3 0 -5 -5.7 03/16/2007 13:50:00 22.2 1.3 25.2 17.6 22.1 1.4 24.8 16.8 20.9 1.9 24.4 14.1 297 17 303 165 -5 0 -4.8 -5.3 03/16/2007 14:00:00 22.5 1.1 24.4 17.6 22.3 1.1 24.4 17.6 20.6 1.5 24.4 15.6 297 17 302 165 -5 0 -4.8 -5.5 03/16/2007 14:10:00 22.1 1.5 25.2 17.6 22 1.6 25.2 17.2 20.9 1.6 25.2 16.1 299 17 287 165 -5 0 -4.6 -5.3 03/16/2007 14:20:00 19.7 1.7 23.3 15.6 19.6 1.7 23.7 15.6 18.3 2.1 23.3 12.6 300 17 309 165 -4.8 0 -4.6 -5.3 03/16/2007 14:30:00 21 1.7 24 16.8 21 1.7 24.4 16.4 17.9 1.7 21.8 13.3 297 14 307 165 -4.8 0 -4.6 -5 03/16/2007 14:40:00 19.4 1.8 23.7 14.5 19.3 1.9 23.7 13.7 16.3 2.1 21.8 9.9 294 17 288 165 -4.8 0.1 -4.6 -5.3 03/16/2007 14:50:00 18.5 1.3 21 13.7 18.4 1.4 21 13.3 14.6 1.5 17.9 10.7 295 15 291 165 -4.8 0 -4.6 -5 03/16/2007 15:00:00 18.4 1.5 21.4 13 18.3 1.5 21.4 13 14.4 1.7 18.7 9.1 295 15 297 165 -4.9 0 -4.6 -5 03/16/2007 15:10:00 17.9 1.3 21.4 13.7 17.8 1.4 21 13.7 14.4 1.6 19.9 10.7 296 14 303 165 -4.9 0 -4.8 -5.3 03/16/2007 15:20:00 18.7 1.2 21 15.3 18.6 1.2 21 15.3 15.3 1.9 19.5 10.7 297 12 276 165 -5 0 -4.8 -5.3 03/16/2007 15:30:00 16.8 1.3 19.9 11.5 16.8 1.4 19.9 11.5 13.9 1.9 18.7 8.8 297 16 284 165 -5 0 -4.8 -5.5 03/16/2007 15:40:00 15.3 1.5 18.7 11.5 15.3 1.5 19.1 11.1 12.5 1.8 17.2 8.8 294 16 298 165 -4.9 0 -4.6 -5.3 03/16/2007 15:50:00 14.9 2.3 19.1 10.3 14.9 2.3 19.1 10.3 11.5 1.7 17.2 8 291 15 287 165 -4.9 0 -4.6 -5.5 03/16/2007 16:00:00 15.5 1.3 19.1 11.1 15.4 1.3 18.7 10.7 12.6 2.1 17.6 8.4 295 17 304 165 -4.9 0 -4.6 -5.3 03/16/2007 16:10:00 16.4 1.4 19.9 11.5 16.4 1.4 19.5 11.8 12.3 1.7 16.4 9.1 295 13 305 165 -4.9 0 -4.6 -5 03/16/2007 16:20:00 16.1 1.6 20.6 12.6 16.1 1.6 20.2 12.6 12.1 1.7 19.5 8.8 290 16 252 165 -5 0 -4.8 -5.3 03/16/2007 16:30:00 16.4 1.4 20.2 11.5 16.4 1.4 19.9 11.5 11.9 1.3 15.6 8 292 13 264 165 -5.2 0 -5 -5.5 03/16/2007 16:40:00 16.3 1.6 19.9 11.1 16.2 1.6 19.9 11.1 12.1 1.7 17.6 8.4 289 15 289 165 -5.3 0 -5 -5.5 03/16/2007 16:50:00 17.1 1.8 21.4 12.6 17 1.8 21.4 12.2 12.8 2 21 9.1 289 18 302 165 -5.2 0 -5 -5.5 03/16/2007 17:00:00 17.2 1.3 20.6 13.3 17.1 1.3 20.6 13 13.5 1.9 18.3 9.5 292 17 290 165 -5.3 0 -5 -5.5 03/16/2007 17:10:00 16.7 1.5 20.2 12.2 16.5 1.5 19.9 11.8 13.3 1.6 19.1 8 290 20 286 165 -5.1 0 -5 -5.5 03/16/2007 17:20:00 14.7 1.8 19.1 9.1 14.6 1.7 20.2 8.8 12.3 1.8 18.7 6.5 291 22 265 165 -4.9 0.1 -4.6 -5.3 03/16/2007 17:30:00 12.7 2 20.2 7.6 12.5 2 21 8.4 11.2 1.7 15.6 6.5 302 22 271 165 -4.5 0 -4.4 -5 03/16/2007 17:40:00 11.4 2.4 19.5 6.1 11.2 2.3 18.3 6.5 10.5 2.3 17.2 4.6 315 22 350 165 -4.2 0.1 -3.9 -4.6 03/16/2007 17:50:00 11.4 2.2 17.2 6.5 11.2 2.2 16.8 6.5 10.8 2.2 16.8 6.5 327 20 320 165 -4 0.1 -3.7 -4.2 03/16/2007 18:00:00 10.1 1.5 13.7 6.1 10.1 1.5 13.3 6.5 8.7 1.6 13.3 4.9 304 17 307 165 -4.5 0.3 -3.9 -5 03/16/2007 18:10:00 9.7 1.7 13.7 5.7 9.6 1.7 14.1 5.7 8.2 1.5 12.2 4.6 298 21 273 165 -4.9 0 -4.6 -5.3 03/16/2007 18:20:00 12.6 2 17.9 6.1 12.5 1.9 17.6 6.1 10.6 2 17.6 5.3 294 22 313 165 -5.3 0 -5 -5.5 03/16/2007 18:30:00 12.8 2.5 18.3 6.5 12.7 2.5 18.3 5.7 11.6 2.5 18.3 4.9 302 22 312 165 -5.2 0.1 -5 -5.7 03/16/2007 18:40:00 13.7 2.2 19.9 7.6 13.6 2.2 19.5 7.6 11.8 2.1 20.2 6.5 295 24 261 165 -5.5 0.2 -5 -5.9 03/16/2007 18:50:00 13.7 2.1 18.7 8 13.5 2.1 18.7 7.6 11.2 1.9 16.4 7.2 288 21 249 165 -6.1 0.1 -5.7 -6.4 03/16/2007 19:00:00 14.9 2.4 21.4 9.1 14.7 2.4 21.8 9.9 12.4 2.6 22.6 7.6 292 20 307 165 -6.5 0 -6.1 -6.6 03/16/2007 19:10:00 16.3 2.1 21 11.1 16.2 2 21 11.1 13.6 1.9 20.2 8.8 292 20 313 165 -6.4 0.1 -6.1 -6.6 03/16/2007 19:20:00 15.4 2.1 22.1 9.1 15.2 2.1 21.4 9.9 12.6 2.1 19.1 6.8 289 21 274 165 -6.4 0.1 -6.1 -6.8 03/16/2007 19:30:00 15.1 2.1 19.1 9.1 14.8 2 18.7 8.8 12.2 1.9 16.4 6.8 289 21 297 165 -6.5 0 -6.1 -6.6 03/16/2007 19:40:00 15.2 1.8 22.9 9.9 15 1.8 22.1 9.9 12.5 1.8 22.1 8.4 288 21 293 165 -6.4 0.1 -6.1 -6.8 03/16/2007 19:50:00 17 1.9 21.4 12.2 16.9 1.9 21.4 11.8 13.6 1.9 18.7 9.5 288 21 264 165 -6.5 0 -6.1 -6.8 03/16/2007 20:00:00 16.5 1.9 21.8 11.1 16.3 1.8 21 10.7 14 2 19.1 8.8 293 21 300 165 -6.5 0 -6.4 -6.8 03/16/2007 20:10:00 15.3 2.4 21.4 10.3 15.1 2.3 20.6 9.5 13.6 1.7 19.1 9.1 300 22 300 165 -6.4 0.1 -6.1 -6.8 03/16/2007 20:20:00 14.3 2.2 20.2 8.4 14.1 2.2 19.5 8.8 12.7 2.5 19.5 5.7 298 23 323 165 -6.2 0.3 -5.7 -6.8 03/16/2007 20:30:00 17.5 1.7 21 11.8 17.3 1.7 20.6 11.5 13.9 1.8 19.9 8.4 284 23 306 165 -6.4 0.1 -6.1 -6.8 03/16/2007 20:40:00 17 2.3 22.6 7.2 16.9 2.2 22.1 7.2 13.7 1.9 19.9 8.4 285 22 300 165 -6.4 0 -6.1 -6.6 03/16/2007 20:50:00 16.1 2.8 22.6 9.5 16 2.8 22.6 9.5 13.4 2.6 21 7.2 290 21 240 165 -6.5 0 -6.4 -6.8 03/16/2007 21:00:00 19.3 1.8 24 13.7 19.2 1.7 23.7 14.1 15.5 2 20.2 11.1 288 22 265 165 -6.6 0 -6.4 -6.8 03/16/2007 21:10:00 19.3 1.7 23.3 14.1 19.1 1.7 22.6 13.7 15.4 1.9 21 10.7 288 22 288 165 -6.6 0 -6.4 -6.8 03/16/2007 21:20:00 19.1 1.9 23.7 13.7 18.9 1.8 24 13.7 15.1 1.7 22.1 10.3 287 21 307 165 -6.6 0 -6.6 -6.8 03/16/2007 21:30:00 19.8 1.8 23.3 14.1 19.5 1.8 22.9 13.3 14.9 1.8 20.2 10.3 286 21 293 165 -6.6 0 -6.6 -6.8 03/16/2007 21:40:00 19.9 2 24.4 13.3 19.7 2 24 13.3 15.2 1.8 19.9 9.9 288 18 298 165 -6.6 0 -6.6 -6.8 03/16/2007 21:50:00 20.1 1.7 25.6 14.9 19.9 1.7 25.6 14.5 15 1.8 22.1 10.3 289 17 301 165 -6.5 0 -6.4 -6.8 03/16/2007 22:00:00 19.1 1.8 24 12.2 19 1.8 23.7 12.6 14.5 1.7 20.2 9.9 290 17 290 165 -6.5 0 -6.4 -6.8 03/16/2007 22:10:00 19.1 1.7 23.7 13 19 1.7 23.7 13 14.4 2.2 21.4 10.3 290 17 277 165 -6.5 0 -6.4 -6.8 03/16/2007 22:20:00 18.9 1.8 22.6 14.1 18.7 1.8 22.6 13.7 14.6 1.9 20.6 10.3 291 20 286 165 -6.5 0 -6.4 -6.8 03/16/2007 22:30:00 18.9 1.3 22.6 15.3 18.8 1.3 22.9 14.9 13.7 1.5 17.6 9.5 289 17 293 165 -6.5 0 -6.4 -6.8 03/16/2007 22:40:00 18.6 1.3 21.4 15.3 18.6 1.3 21.4 15.3 13.6 1.6 19.5 10.3 291 17 278 165 -6.5 0 -6.4 -6.8 03/16/2007 22:50:00 17.6 1.5 21.4 13 17.5 1.5 21.4 13 12.9 1.3 16.4 9.1 288 17 291 165 -6.5 0 -6.4 -6.8 03/16/2007 23:00:00 17.7 1.7 21.4 13 17.7 1.7 21 12.6 12.6 1.3 18.3 9.5 289 18 293 165 -6.4 0 -6.4 -6.8 03/16/2007 23:10:00 17 1.7 19.9 11.8 16.9 1.7 19.9 11.1 12.6 1.5 16.8 8.8 287 19 296 165 -6.5 0 -6.1 -6.8 03/16/2007 23:20:00 16.5 1.5 19.5 11.8 16.5 1.5 19.5 11.8 12.3 1.3 17.9 9.1 288 19 268 165 -6.5 0 -6.4 -6.8 03/16/2007 23:30:00 17.2 1.1 19.5 13.7 17.1 1.2 19.9 13.3 12.7 1.5 17.2 9.5 291 17 300 165 -6.5 0 -6.4 -6.8 03/16/2007 23:40:00 16.6 1.3 19.9 12.2 16.5 1.3 19.5 12.6 12.5 1.3 17.2 9.5 287 20 298 165 -6.5 0 -6.4 -6.8 03/16/2007 23:50:00 16.8 1.3 20.2 12.2 16.6 1.4 20.2 12.2 12.6 1.5 16.4 9.1 289 19 298 165 -6.5 0 -6.4 -6.8 03/17/2007 00:00:00 15.9 1.5 19.9 11.1 15.8 1.5 19.5 11.5 12 1.5 16.8 8.8 288 22 295 165 -6.7 0 -6.6 -6.8 03/17/2007 00:10:00 16 1.2 18.7 12.6 16 1.2 18.7 12.2 12.3 1.5 17.2 8.8 291 17 301 165 -6.7 0 -6.6 -7 03/17/2007 00:20:00 14 1.3 19.1 10.3 13.9 1.4 18.7 10.3 11.5 1.5 16.1 8 293 19 299 165 -6.8 0 -6.6 -6.8 03/17/2007 00:30:00 14.3 1.3 17.2 8.4 14.2 1.3 17.2 8.4 10.8 1.3 16.8 7.2 289 17 282 165 -6.7 0 -6.6 -7 03/17/2007 00:40:00 13.2 1.3 16.4 9.1 13.2 1.4 16.8 9.1 9.9 1.2 14.1 7.2 285 18 295 165 -6.7 0 -6.6 -7 03/17/2007 00:50:00 12.5 1.4 16.4 8.8 12.4 1.5 16.4 9.1 9.7 1.3 13.7 6.5 285 21 299 165 -6.8 0 -6.6 -7 03/17/2007 01:00:00 13.1 1.7 16.8 9.5 13 1.7 16.8 9.5 9.8 1.4 14.5 6.8 287 19 295 165 -6.7 0 -6.6 -7 03/17/2007 01:10:00 12.9 1.3 16.1 9.1 12.8 1.3 16.1 9.5 9.8 1.2 13.7 6.8 286 19 281 165 -6.8 0 -6.6 -7.2 03/17/2007 01:20:00 13 1 15.6 9.9 13 1 15.6 9.9 9.8 1.1 13 7.2 288 19 302 165 -6.8 0 -6.6 -7.2 03/17/2007 01:30:00 13.6 1.2 16.4 9.9 13.6 1.2 16.4 9.5 10.6 1.2 14.5 7.6 293 18 256 165 -6.8 0 -6.6 -7 03/17/2007 01:40:00 13.8 1.3 16.1 9.9 13.8 1.3 16.1 9.9 11.1 1.3 15.6 8 292 17 294 165 -6.6 0 -6.6 -6.8 03/17/2007 01:50:00 14.4 1 16.4 11.5 14.5 1.1 16.8 11.5 10.6 1.3 15.6 7.6 290 17 299 165 -6.5 0 -6.4 -6.8 03/17/2007 02:00:00 14.5 1 16.8 9.9 14.5 1 17.2 9.9 11.2 1.6 16.4 8.4 293 16 274 165 -6.6 0 -6.6 -6.8 03/17/2007 02:10:00 14.5 1.1 16.4 11.5 14.5 1.2 16.4 11.1 12 1.5 16.4 8.8 295 17 299 165 -6.6 0 -6.6 -7 03/17/2007 02:20:00 14.3 1.1 16.1 11.1 14.3 1.1 16.4 11.5 11.8 1.3 15.3 8.4 295 15 307 165 -6.5 0 -6.4 -6.8 03/17/2007 02:30:00 14.5 0.7 16.1 12.6 14.5 0.7 16.1 12.2 12.3 1.1 15.3 8.8 304 5 297 165 -6.5 0 -6.4 -6.8 03/17/2007 02:40:00 14.3 0.7 15.6 11.8 14.3 0.7 15.6 11.5 12.4 1.2 15.3 8.8 306 4 309 165 -6.4 0 -6.1 -6.8 03/17/2007 02:50:00 14.3 1 16.1 11.1 14.2 1 16.1 11.1 12.2 1 14.9 8.8 306 5 304 165 -6.4 0 -6.1 -6.6 03/17/2007 03:00:00 12.7 1 15.3 9.9 12.6 1 15.3 9.9 11.4 1.1 13.7 6.8 306 6 310 165 -6.5 0 -6.4 -6.8 03/17/2007 03:10:00 12.9 0.9 14.5 9.9 12.8 0.9 14.5 9.5 10.5 1.3 13.3 7.6 304 6 299 165 -6.4 0.1 -6.1 -6.8 03/17/2007 03:20:00 12.3 1 14.5 9.9 12.2 1 14.5 9.9 10 1.5 13.7 6.1 303 6 305 165 -6.5 0 -6.4 -6.6 03/17/2007 03:30:00 11 1 13.3 8.4 11 1 13 8.4 8.2 0.9 11.5 6.1 300 6 301 165 -6.5 0 -6.4 -6.8 03/17/2007 03:40:00 11.5 0.9 13.3 8.8 11.6 0.9 13.3 8.8 8.4 0.9 10.7 6.5 296 6 301 165 -6.4 0 -6.1 -6.8 03/17/2007 03:50:00 11.4 0.7 13 9.1 11.4 0.7 13 9.5 8.2 0.9 11.5 6.5 299 6 299 165 -6.3 0 -6.1 -6.6 03/17/2007 04:00:00 11.1 0.9 13.3 8.8 11.2 0.9 13.3 8.8 8.1 0.9 10.7 6.5 300 6 299 165 -6.4 0 -6.1 -6.6 03/17/2007 04:10:00 10 0.7 11.8 8 10 0.7 11.8 8 7.7 1.1 10.7 5.3 303 5 304 165 -6.1 0 -5.9 -6.6 03/17/2007 04:20:00 10.7 0.7 12.6 8.8 10.8 0.8 12.6 8.8 7.7 0.8 10.3 5.7 298 5 297 165 -5.9 0.1 -5.7 -6.6 03/17/2007 04:30:00 10.3 1.1 13 7.2 10.4 1.1 12.6 7.2 7.7 1 10.3 5.3 300 5 309 165 -5.9 0 -5.7 -5.9 03/17/2007 04:40:00 10.9 1 13 8 10.9 1 13 7.6 8.8 1.2 12.6 6.5 304 7 296 165 -5.8 0 -5.5 -6.1 03/17/2007 04:50:00 10.2 1.3 13.3 7.2 10.2 1.3 13.3 6.8 8.4 1.7 13 4.6 302 6 303 165 -5.9 0 -5.7 -6.1 03/17/2007 05:00:00 8.5 1.1 11.8 5.3 8.5 1.1 11.8 4.9 7.1 1.2 9.9 4.2 304 8 296 165 -6 0 -5.7 -6.4 03/17/2007 05:10:00 6.5 0.9 9.5 4.6 6.5 0.9 9.5 4.9 5.9 1 8.4 3.4 311 8 305 165 -6.1 0 -5.9 -6.4 03/17/2007 05:20:00 6.4 0.7 8.8 4.6 6.4 0.7 8.4 4.9 6 0.9 8.8 3.8 312 8 313 165 -6 0.1 -5.7 -6.6 03/17/2007 05:30:00 5.8 0.6 7.6 4.6 5.8 0.6 7.6 4.2 5.2 0.8 7.6 3.4 308 9 310 165 -5.7 0 -5.5 -5.9 03/17/2007 05:40:00 7.3 0.6 8.8 5.3 7.3 0.6 8.8 5.3 5.5 0.6 8.4 4.2 300 4 300 165 -5.5 0 -5.5 -5.7 03/17/2007 05:50:00 8 0.5 9.1 6.8 8.1 0.5 9.1 6.8 5.7 0.6 8 4.6 299 4 297 165 -5.6 0 -5.5 -6.1 03/17/2007 06:00:00 8.7 0.5 9.9 7.6 8.7 0.5 9.9 7.6 6.2 0.6 8.4 4.9 300 5 285 165 -5.7 0 -5.5 -5.9 03/17/2007 06:10:00 8.9 0.5 9.9 7.6 9 0.5 10.3 7.6 6.5 0.7 8.8 4.9 299 4 297 165 -5.5 0 -5.3 -5.9 03/17/2007 06:20:00 8.5 0.8 10.3 6.1 8.6 0.8 10.3 6.1 6.6 0.9 9.1 4.2 297 6 298 165 -5.8 0 -5.5 -5.9 03/17/2007 06:30:00 8.6 0.8 10.7 6.5 8.6 0.8 10.7 6.5 7 1 9.5 4.9 296 6 292 165 -5.7 0 -5.5 -5.9 03/17/2007 06:40:00 8.8 0.8 11.1 6.5 8.9 0.8 11.5 6.8 6.8 1 9.9 4.9 301 5 304 165 -5.7 0 -5.5 -5.7 03/17/2007 06:50:00 7.1 1.6 10.7 4.6 7.2 1.6 11.1 4.6 6.2 1.1 9.9 3.8 308 7 306 165 -5.9 0.1 -5.5 -6.1 03/17/2007 07:00:00 5.8 0.8 8 3.8 5.8 0.8 8 3.8 5.3 0.8 7.6 3.4 308 8 305 165 -5.5 0.3 -5 -6.1 03/17/2007 07:10:00 5.7 0.9 8 2.6 5.7 0.9 7.6 3 5.3 0.9 7.2 2.6 311 8 302 165 -5.6 0 -5.3 -5.9 03/17/2007 07:20:00 4.1 0.7 6.1 2.6 4.1 0.7 5.7 2.3 3.7 0.6 5.3 2.3 309 10 295 165 -5.7 0.1 -5.5 -5.9 03/17/2007 07:30:00 3.5 0.5 4.6 2.3 3.5 0.5 4.6 1.9 3.2 0.5 4.6 1.9 309 10 316 165 -5.5 0 -5.3 -5.7 03/17/2007 07:40:00 2.3 0.3 3.4 1.9 2.3 0.3 3.4 1.9 2.7 0.3 3.8 1.5 326 9 319 165 -5.6 0 -5.5 -5.9 03/17/2007 07:50:00 1.2 0.5 2.3 0.4 1.1 0.7 2.3 0.4 1.9 0.5 3 0.7 348 14 333 165 -5 0.5 -4.2 -5.9 03/17/2007 08:00:00 0.4 0 0.7 0.4 0.4 0.1 1.1 0.4 0.5 0.3 1.5 0.4 333 49 268 165 -3.7 0.3 -3.3 -4.4 03/17/2007 08:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0.1 1.1 0.4 152 9 165 165 -3.5 0.2 -3.3 -3.9 03/17/2007 08:20:00 0.6 0.4 1.9 0.4 0.5 0.3 1.5 0.4 1.3 0.4 2.3 0.4 186 13 207 165 -3.8 0.1 -3.5 -4.2 03/17/2007 08:30:00 3.2 1.2 6.1 0.7 3.4 1.4 5.7 0.4 3.5 1.2 5.7 0.7 260 22 282 165 -4.2 0.4 -3.5 -5 03/17/2007 08:40:00 5.1 0.5 6.5 4.2 5.1 0.5 6.5 4.2 4.8 0.6 6.5 3 287 5 294 165 -5.2 0.1 -4.8 -5.5 03/17/2007 08:50:00 4.6 0.5 5.7 3.4 4.7 0.5 5.7 3.4 4.3 0.7 5.7 3 291 5 284 165 -5.3 0.1 -5 -5.7 03/17/2007 09:00:00 4 0.4 5.3 3 4 0.4 5.3 3 3.2 0.6 4.9 1.9 296 6 295 165 -4.9 0 -4.6 -5.3 03/17/2007 09:10:00 2.9 0.4 4.2 1.9 2.9 0.4 4.2 1.9 2.9 0.4 4.2 1.9 314 12 289 165 -4.9 0.2 -4.4 -5.3 03/17/2007 09:20:00 2.8 0.3 3.4 2.3 2.7 0.3 3.4 2.3 2.8 0.4 3.4 1.5 317 9 319 165 -4.3 0.1 -3.9 -4.8 03/17/2007 09:30:00 3.3 0.4 4.6 1.9 3.2 0.4 4.6 2.3 3.2 0.5 4.6 1.5 315 7 314 165 -4.3 0.2 -3.9 -4.8 03/17/2007 09:40:00 3.1 0.3 3.8 2.6 3.1 0.3 3.8 2.6 3 0.4 3.8 1.9 314 6 315 165 -4.2 0.2 -3.7 -4.6 03/17/2007 09:50:00 3.6 0.7 5.3 1.9 3.6 0.8 5.3 1.9 3.3 1 5.3 1.5 289 8 289 165 -4.4 0.4 -3.5 -5 03/17/2007 10:00:00 4.9 0.7 6.1 3.4 4.9 0.7 6.1 3.4 4.6 0.8 6.5 2.3 284 7 282 165 -5.2 0.1 -5 -5.5 03/17/2007 10:10:00 5 0.7 6.8 3.8 5 0.7 6.8 3.8 4.1 0.8 6.5 2.6 296 6 296 165 -5.4 0.1 -5 -5.9 03/17/2007 10:20:00 5.3 0.5 6.5 3.8 5.4 0.5 6.5 3.8 4.9 0.8 6.5 2.6 287 6 277 165 -5.3 0.2 -5 -5.9 03/17/2007 10:30:00 5.7 0.5 6.8 4.2 5.7 0.5 6.8 3.8 4.7 0.9 6.8 2.6 294 6 291 165 -5.3 0.2 -5 -5.9 03/17/2007 10:40:00 4.7 0.4 5.7 3.8 4.7 0.4 5.7 3.8 3.7 0.6 5.3 2.3 296 5 297 165 -5 0.2 -4.6 -5.7 03/17/2007 10:50:00 4.4 0.4 5.3 3.4 4.4 0.4 5.3 3.4 4 0.8 5.7 2.3 292 5 282 165 -4.8 0 -4.6 -5 03/17/2007 11:00:00 4.7 0.5 6.1 3.4 4.7 0.5 6.1 3.8 4.4 0.6 6.1 2.6 289 5 285 165 -4.7 0.1 -4.4 -5 03/17/2007 11:10:00 4.7 0.5 6.1 3.4 4.8 0.6 6.1 3.4 4.3 0.7 6.1 2.3 289 7 293 165 -4.8 0 -4.6 -5 03/17/2007 11:20:00 4.6 0.5 6.1 3.4 4.7 0.5 6.1 3.4 4.4 0.7 6.1 2.6 286 5 283 165 -4.7 0 -4.4 -5 03/17/2007 11:30:00 4.1 0.4 5.3 3 4.2 0.4 5.3 3.4 3.8 0.6 5.3 2.3 291 5 285 165 -4.5 0.1 -4.4 -5 03/17/2007 11:40:00 3.6 0.3 4.2 3 3.6 0.3 4.6 2.6 3.1 0.5 4.2 1.9 293 5 293 165 -4.2 0.1 -3.7 -4.6 03/17/2007 11:50:00 4 0.5 4.9 2.3 4 0.5 4.9 2.6 3.9 0.5 4.9 2.3 288 4 284 165 -4.2 0 -3.7 -4.4 03/17/2007 12:00:00 4.6 0.4 5.7 3.8 4.6 0.4 5.3 3.8 4.2 0.6 5.7 2.3 290 5 287 165 -4.4 0 -3.9 -4.6 03/17/2007 12:10:00 5 0.5 6.1 3.4 5 0.5 6.5 3.4 4.7 0.7 6.1 3 287 4 282 165 -4.5 0 -4.4 -4.6 03/17/2007 12:20:00 5.6 0.4 6.8 4.6 5.6 0.4 6.8 4.6 5.3 0.7 6.8 3 286 6 290 165 -4.5 0 -4.4 -4.6 03/17/2007 12:30:00 5.2 0.5 6.5 3.8 5.2 0.5 6.1 3.8 4.7 0.9 6.5 2.6 287 7 289 165 -4.3 0 -3.9 -4.6 03/17/2007 12:40:00 4.4 0.5 5.7 3.4 4.5 0.5 5.7 3.4 3.8 0.7 6.1 2.3 294 5 287 165 -4.2 0 -3.9 -4.4 03/17/2007 12:50:00 4 0.5 5.7 2.6 4 0.5 5.7 2.6 3.7 0.7 5.7 1.9 292 7 285 165 -4 0 -3.9 -4.2 03/17/2007 13:00:00 3.9 0.5 5.3 2.6 3.9 0.5 5.3 2.6 3.5 0.7 5.3 2.3 295 6 285 165 -3.9 0 -3.7 -4.4 03/17/2007 13:10:00 4.8 0.6 6.1 3.4 4.8 0.7 6.5 3.4 4.5 1 6.5 2.6 289 8 285 165 -3.9 0 -3.7 -4.2 03/17/2007 13:20:00 5.1 0.8 6.8 3 5.1 0.8 6.8 3 4.8 0.9 6.8 1.9 288 6 285 165 -4 0 -3.9 -4.4 03/17/2007 13:30:00 4.7 0.7 6.5 3 4.7 0.8 6.5 2.6 4.1 0.8 6.5 2.3 297 9 296 165 -3.6 0.1 -3.3 -4.2 03/17/2007 13:40:00 4.3 0.5 5.3 3 4.3 0.5 5.7 3 3.7 0.8 5.7 1.9 292 7 294 165 -3.7 0.1 -3.5 -3.9 03/17/2007 13:50:00 4.4 0.6 6.1 2.6 4.4 0.6 6.1 2.6 3.8 0.6 5.3 2.3 299 8 307 165 -3.7 0.1 -3.3 -3.9 03/17/2007 14:00:00 4.3 0.6 6.1 3 4.4 0.6 6.1 3 3.6 0.6 5.3 2.3 298 7 301 165 -3.4 0.1 -3 -3.5 03/17/2007 14:10:00 5 0.6 6.5 3.4 5 0.6 6.5 3.4 4.3 0.6 6.1 2.3 302 7 295 165 -3.5 0 -3.3 -3.7 03/17/2007 14:20:00 5.2 0.6 6.5 3.4 5.2 0.6 6.5 3.4 4.3 0.6 5.7 2.6 302 7 298 165 -3.5 0 -3.3 -3.7 03/17/2007 14:30:00 5.9 0.6 6.8 3.8 5.9 0.6 7.2 3.8 4.7 0.6 6.5 3 302 6 304 165 -3.4 0.2 -3 -3.9 03/17/2007 14:40:00 6.6 0.4 7.6 4.9 6.6 0.4 7.6 4.9 5.4 0.6 7.2 3.8 304 4 299 165 -4.4 0.1 -3.9 -4.6 03/17/2007 14:50:00 6.7 0.5 7.6 4.9 6.7 0.6 7.6 4.9 5.6 0.7 7.2 3.8 304 5 303 165 -4 0.1 -3.5 -4.4 03/17/2007 15:00:00 6.2 0.5 7.6 4.9 6.3 0.6 7.6 4.9 4.9 0.6 6.8 3 300 6 297 165 -4 0 -3.7 -4.4 03/17/2007 15:10:00 5.3 0.6 6.8 3.4 5.2 0.6 6.5 3.4 5 0.7 6.8 3 318 13 306 165 -3.2 0.4 -2.4 -4.2 03/17/2007 15:20:00 4.6 0.5 6.1 3 4.5 0.5 5.7 3 4.5 0.5 6.1 3.4 327 8 333 165 -2.1 0.2 -1.4 -2.8 03/17/2007 15:30:00 4.5 0.4 5.7 3.4 4.4 0.6 5.7 2.3 4.5 0.5 5.7 3 339 9 342 165 -2.5 0.1 -2.1 -2.8 03/17/2007 15:40:00 4.6 0.6 6.1 3 4.5 0.6 6.1 2.6 4.6 0.6 6.1 3 324 9 317 165 -3.3 0.3 -2.6 -3.7 03/17/2007 15:50:00 4.8 0.5 5.7 3 4.7 0.5 5.7 2.6 4.7 0.6 6.1 3 333 10 318 165 -3.2 0.3 -2.6 -3.5 03/17/2007 16:00:00 5 0.8 6.8 3 5 0.7 6.5 3 5.1 0.7 6.8 3.4 331 7 327 165 -2.5 0 -2.1 -2.8 03/17/2007 16:10:00 4.5 0.6 6.1 3 4.5 0.6 6.1 2.3 4.6 0.7 6.1 3 335 9 324 165 -2.7 0.3 -2.1 -3.3 03/17/2007 16:20:00 4.5 0.6 6.5 3 4.4 0.8 6.5 2.3 4.6 0.6 6.5 3 340 9 328 165 -3.4 0.1 -3 -3.5 03/17/2007 16:30:00 4.3 0.8 6.5 2.6 4.3 0.8 6.5 2.6 4.3 0.8 6.1 2.3 328 12 338 165 -3.7 0 -3.5 -3.9 03/17/2007 16:40:00 4.8 0.6 6.5 3.4 4.8 0.6 6.1 3 4.9 0.6 6.5 3 334 8 352 165 -3.7 0.1 -3.3 -4.2 03/17/2007 16:50:00 5.8 0.8 8.4 4.2 5.8 0.9 8.4 3.4 5.9 0.7 8 4.2 334 9 340 165 -4.2 0.2 -3.9 -4.8 03/17/2007 17:00:00 4.8 0.9 6.8 3 4.7 1 6.8 2.3 4.9 0.9 6.8 3 335 10 335 165 -3.9 0.2 -3.5 -4.6 03/17/2007 17:10:00 5 0.6 6.8 3.4 5 0.7 6.8 3.4 5.1 0.6 6.8 3.8 335 8 334 165 -3.4 0 -3.3 -4.4 03/17/2007 17:20:00 5.4 0.8 7.6 3.4 5.4 0.8 8 3.4 5.5 0.8 7.6 3.4 333 8 343 165 -3.3 0 -3 -3.5 03/17/2007 17:30:00 6.4 0.8 8.8 4.6 6.4 0.8 8.8 4.6 6.6 1 8.4 4.6 332 7 339 165 -3.5 0.2 -3.3 -4.2 03/17/2007 17:40:00 6.4 0.9 8.4 4.2 6.4 0.9 8.4 3.8 6.3 0.9 8.4 3.8 334 8 334 165 -3.5 0.1 -3.3 -4.6 03/17/2007 17:50:00 6.7 0.9 9.5 4.2 6.6 0.9 9.1 4.2 6.4 1 9.5 4.6 324 11 330 165 -4.3 0.3 -3.7 -5 03/17/2007 18:00:00 6.9 1.1 9.5 4.9 6.9 1.1 9.5 4.6 7 1.1 9.9 4.9 335 8 338 165 -4.7 0.1 -4.2 -5 03/17/2007 18:10:00 6.5 1.1 9.1 3.8 6.4 1.2 9.5 4.2 6.5 1.1 9.1 4.2 336 12 342 165 -4.8 0 -4.6 -5 03/17/2007 18:20:00 7.1 1.1 9.5 4.9 7.1 1.2 9.9 4.6 7.2 1.1 10.3 4.6 335 9 338 165 -5 0 -4.8 -5 03/17/2007 18:30:00 6.2 1.3 9.5 3.8 6.1 1.3 9.9 3.4 6.1 1.1 9.1 3.4 337 9 340 165 -4.9 0 -4.6 -5.3 03/17/2007 18:40:00 6.5 1.5 9.9 3.8 6.5 1.5 10.3 3.8 6.6 1.4 9.9 3.8 333 9 339 165 -5 0 -4.6 -5.3 03/17/2007 18:50:00 7.8 1.1 11.1 5.3 7.8 1.2 11.1 4.2 7.9 1.1 10.7 4.2 338 8 335 165 -5.3 0 -5 -5.5 03/17/2007 19:00:00 6.4 1.1 9.1 4.2 6.4 1.1 9.1 3.8 6.4 1.1 8.8 3.8 335 7 334 165 -5.5 0 -5.5 -5.7 03/17/2007 19:10:00 6.5 1 8.4 4.6 6.5 1 8.8 4.6 5.6 0.9 8 3 299 11 287 165 -5.9 0 -5.5 -6.1 03/17/2007 19:20:00 6.4 0.6 8.8 4.9 6.4 0.6 8.4 4.9 5.6 0.8 8 3.4 297 8 294 165 -6.1 0 -5.9 -6.4 03/17/2007 19:30:00 7.1 0.8 9.1 4.6 7.2 0.8 9.5 4.6 5.9 1 9.1 3.8 295 6 289 165 -6.1 0 -5.9 -6.4 03/17/2007 19:40:00 6.3 0.7 8 4.2 6.3 0.7 8 4.6 5.4 0.8 8.4 4.2 298 7 296 165 -6.2 0 -5.9 -6.6 03/17/2007 19:50:00 7.2 0.8 9.1 4.2 7.2 0.8 8.8 4.2 6.5 1.2 9.1 3.8 290 7 299 165 -6.5 0 -6.1 -6.6 03/17/2007 20:00:00 7.8 0.9 10.3 5.3 7.8 0.8 9.9 4.9 6.7 1.1 10.3 4.2 307 10 312 165 -6.6 0 -6.4 -6.8 03/17/2007 20:10:00 7.5 0.9 10.3 5.3 7.5 0.8 10.3 5.3 6.8 1.2 10.7 3.8 313 12 335 165 -6.4 0 -6.1 -6.8 03/17/2007 20:20:00 6.3 0.8 8.4 4.2 6.3 0.8 8.4 4.6 5.4 0.8 7.6 3 304 13 327 165 -6.7 0 -6.6 -6.8 03/17/2007 20:30:00 6.5 0.8 8.8 4.2 6.5 0.8 8.8 3.8 5.6 1 9.1 3 299 11 292 165 -6.9 0 -6.6 -7.2 03/17/2007 20:40:00 7.3 1.1 10.7 5.3 7.4 1.1 10.7 5.3 6.2 1.4 9.9 3.4 294 7 292 165 -6.9 0.1 -6.6 -7.2 03/17/2007 20:50:00 7.9 1.1 10.7 5.3 7.9 1.1 10.3 5.3 6.6 1.3 9.9 3.8 295 8 290 165 -7.2 0.1 -6.8 -7.4 03/17/2007 21:00:00 6.1 0.9 8.8 4.6 6.1 0.9 8.8 4.6 5 1 8.4 3 302 8 294 165 -7.4 0 -7.2 -7.4 03/17/2007 21:10:00 6.4 0.7 8.8 4.6 6.5 0.7 8.8 4.9 5.6 0.7 7.2 3.8 304 8 303 165 -7.2 0 -7 -7.4 03/17/2007 21:20:00 5.4 0.8 7.6 3.8 5.4 0.8 7.6 3.8 5.2 0.7 7.2 3.4 313 9 297 165 -7.1 0 -6.8 -7.4 03/17/2007 21:30:00 6.3 0.9 9.5 3.8 6.3 0.8 9.1 4.2 5.5 1 8.4 3.4 303 14 332 165 -7.3 0.1 -7 -7.4 03/17/2007 21:40:00 7.8 0.8 9.9 6.1 7.7 0.7 9.5 6.1 7.3 1.2 9.5 4.6 320 13 329 165 -7.3 0.1 -7.2 -7.6 03/17/2007 21:50:00 7.9 1.1 12.2 6.1 7.9 1.1 11.5 5.7 7 1.2 12.6 4.2 307 8 313 165 -7.5 0.1 -7 -7.9 03/17/2007 22:00:00 9.3 1.5 13.3 5.7 9.4 1.5 13.7 5.7 8.4 1.4 13.3 4.9 299 10 309 165 -7.2 0.1 -6.8 -7.4 03/17/2007 22:10:00 7.2 1.1 9.9 4.9 7.3 1.1 9.9 4.9 6.8 1.2 9.9 4.2 295 12 285 165 -7.3 0.1 -6.8 -7.6 03/17/2007 22:20:00 7.6 1.1 10.3 4.6 7.6 1.1 10.3 4.6 6.6 1.1 10.3 4.6 298 9 285 165 -7.3 0 -7.2 -7.4 03/17/2007 22:30:00 7.5 1.1 9.9 3.8 7.6 1 9.9 4.6 6.7 1.2 9.9 3.4 298 12 282 165 -7.4 0 -7.2 -7.6 03/17/2007 22:40:00 7.6 1.2 10.3 4.6 7.7 1.2 10.3 4.9 7.2 1.3 10.7 4.2 295 9 286 165 -7.4 0.1 -6.8 -7.6 03/17/2007 22:50:00 7.7 1 9.9 5.3 7.8 1 10.3 5.7 6.8 1 10.3 4.9 298 11 288 165 -7.3 0 -7.2 -7.6 03/17/2007 23:00:00 7.6 1.2 10.3 2.3 7.6 1.2 9.5 1.9 6.8 1.2 9.1 3.4 296 9 305 165 -7.3 0 -7.2 -7.4 03/17/2007 23:10:00 7.9 1 10.3 4.9 8 1 9.9 5.3 6.6 0.9 9.1 4.2 300 9 285 165 -7.4 0 -7.2 -7.4 03/17/2007 23:20:00 9.2 1 12.2 6.1 9.2 1 12.6 6.1 8.2 1.4 13 5.3 293 7 286 165 -7.5 0 -7.2 -7.6 03/17/2007 23:30:00 8.3 1.1 11.5 5.7 8.3 1 11.5 5.3 7.6 1.3 11.5 4.6 294 10 286 165 -7.4 0 -7.2 -7.6 03/17/2007 23:40:00 9.3 1.3 13 5.3 9.4 1.3 13 5.7 8.5 1.4 12.2 5.3 292 10 291 165 -7.3 0 -7.2 -7.6 03/17/2007 23:50:00 8.6 1.5 11.5 4.9 8.7 1.5 11.5 4.9 8.3 1.5 12.2 4.6 290 10 291 165 -7.2 0 -6.8 -7.4 03/18/2007 00:00:00 9.4 1.5 13 4.9 9.5 1.5 13 5.7 9.7 1.6 13 5.3 287 9 278 165 -7.4 0.1 -7.2 -7.6 03/18/2007 00:10:00 9.4 1.8 13.7 4.9 9.4 1.8 13.7 4.9 8.9 1.7 14.1 5.3 295 14 293 165 -7.5 0 -7.2 -7.6 03/18/2007 00:20:00 9.4 1.6 13.3 5.7 9.4 1.5 13.3 5.7 8.8 1.6 13 5.3 299 15 295 165 -7.3 0 -7.2 -7.4 03/18/2007 00:30:00 8.9 1.4 12.6 4.9 8.9 1.3 12.2 5.7 8.6 1.6 12.2 4.9 294 13 287 165 -7.4 0.1 -7.2 -7.4 03/18/2007 00:40:00 10.6 1.2 13.7 8 10.7 1.1 13.7 7.6 10.2 1.5 14.5 6.8 292 8 290 165 -7.5 0 -7.4 -7.6 03/18/2007 00:50:00 11.6 1.3 15.3 8 11.7 1.3 15.3 8 10.8 1.6 14.1 6.1 290 8 298 165 -7.6 0 -7.4 -7.6 03/18/2007 01:00:00 11.7 1.1 14.1 6.5 11.8 1 14.1 6.8 10.1 1.3 13.7 6.5 295 8 285 165 -7.6 0 -7.4 -7.6 03/18/2007 01:10:00 11.1 1.1 14.1 8.4 11.2 1.1 14.1 8.4 9.9 1.6 13.7 6.5 293 10 290 165 -7.6 0 -7.2 -7.6 03/18/2007 01:20:00 10.6 1.4 14.5 6.5 10.7 1.3 14.1 6.8 9 1.5 13.7 5.7 298 10 311 165 -7.5 0.1 -7.2 -7.6 03/18/2007 01:30:00 10.4 0.9 13 8 10.3 0.9 13 7.6 8.4 1.2 12.2 5.7 296 9 286 165 -7.5 0 -7.2 -7.6 03/18/2007 01:40:00 11.1 1.1 13.7 7.6 11.2 1.1 13.7 7.6 9.8 1.6 14.1 5.3 293 9 290 165 -7.6 0 -7.4 -7.6 03/18/2007 01:50:00 11.7 1.2 15.3 8.4 11.8 1.2 15.3 8.8 10.1 1.6 14.9 6.8 297 9 289 165 -7.6 0 -7.4 -8.1 03/18/2007 02:00:00 11.9 1.5 16.1 7.6 11.9 1.5 15.6 7.6 9.8 1.7 14.5 6.1 297 9 289 165 -7.6 0 -7.4 -8.1 03/18/2007 02:10:00 10.5 1.9 14.5 7.2 10.5 1.9 14.5 7.2 9.4 2.3 14.9 5.7 292 9 289 165 -7.5 0 -7.2 -7.6 03/18/2007 02:20:00 10.6 2.1 14.5 3.4 10.6 2.1 14.9 3.4 9.2 2.4 15.6 3.4 293 10 294 165 -7.5 0 -7.2 -7.6 03/18/2007 02:30:00 11 1.5 16.1 7.2 11 1.6 16.1 6.5 9.4 2.1 15.3 5.7 295 9 294 165 -7.4 0 -7.2 -7.6 03/18/2007 02:40:00 11.7 2 16.4 7.6 11.7 2 16.4 7.6 9.5 1.9 14.5 5.7 299 9 279 165 -7.4 0.1 -7 -7.6 03/18/2007 02:50:00 12.3 1.8 16.1 8 12.3 1.8 16.1 8 9.8 1.7 14.9 6.5 299 8 292 165 -7.5 0 -7.2 -7.6 03/18/2007 03:00:00 11 1.7 15.3 7.2 11 1.7 15.3 7.2 9.4 1.7 15.3 6.1 294 8 293 165 -7.5 0 -7.2 -7.6 03/18/2007 03:10:00 11.1 1.3 14.5 7.6 11.1 1.3 14.1 7.6 9.5 1.6 13.7 5.7 294 9 302 165 -7.5 0 -7.2 -7.6 03/18/2007 03:20:00 10.6 2.2 16.1 6.5 10.6 2.1 16.1 6.1 8.4 1.7 12.6 4.2 294 9 297 165 -7.5 0 -7.2 -7.6 03/18/2007 03:30:00 11 1.8 16.4 5.7 11 1.7 15.6 5.3 8.9 1.7 13 3.4 296 9 299 165 -7.4 0 -7.2 -7.6 03/18/2007 03:40:00 10.3 1.7 15.3 5.3 10.3 1.6 15.3 5.3 8.4 1.6 13 4.9 301 9 309 165 -7.4 0.1 -7.2 -7.6 03/18/2007 03:50:00 10 1.7 15.3 6.5 10 1.7 15.3 6.1 7.9 1.5 13.7 4.6 297 8 295 165 -7.4 0 -7.2 -7.6 03/18/2007 04:00:00 10.6 1.4 13.3 7.2 10.5 1.4 13.3 7.2 8.4 1.3 12.6 4.9 297 9 295 165 -7.4 0 -7.2 -7.4 03/18/2007 04:10:00 10.7 1.7 13.7 6.5 10.6 1.7 14.1 6.1 8.4 1.3 12.2 4.9 297 8 306 165 -7.4 0 -7.2 -7.4 03/18/2007 04:20:00 11.4 1.7 14.5 6.1 11.4 1.7 14.5 6.1 8.7 1.5 14.5 4.2 298 7 298 165 -7.4 0 -7.2 -7.4 03/18/2007 04:30:00 12.6 1.5 16.1 9.1 12.6 1.5 16.1 9.1 9.8 1.6 15.3 6.5 295 7 288 165 -7.4 0.1 -7.2 -7.6 03/18/2007 04:40:00 12.2 1.5 16.4 7.6 12.3 1.5 16.1 7.6 9.8 1.5 14.5 6.5 292 7 291 165 -7.3 0 -7.2 -7.4 03/18/2007 04:50:00 13.3 1.2 15.3 9.5 13.4 1.2 15.6 9.9 11.2 1.7 16.4 7.2 290 6 292 165 -7.4 0 -7.2 -7.4 03/18/2007 05:00:00 12.6 1.6 18.7 8.4 12.7 1.6 18.7 8.4 10.4 1.7 15.3 6.1 291 7 298 165 -7.3 0.1 -6.8 -7.4 03/18/2007 05:10:00 12.4 1.7 16.1 7.6 12.5 1.7 16.1 7.6 10.6 2 16.1 5.7 289 7 292 165 -7.3 0 -7 -7.4 03/18/2007 05:20:00 12.2 1.5 16.4 8.4 12.2 1.5 16.1 8.8 9.5 1.4 13.7 5.7 294 6 297 165 -7.3 0 -7.2 -7.4 03/18/2007 05:30:00 12.3 1.5 15.6 8.4 12.3 1.5 15.3 8.8 9.3 1.3 13 6.5 296 7 296 165 -7.2 0 -7 -7.4 03/18/2007 05:40:00 11.2 1.7 16.8 7.6 11.2 1.7 16.8 7.6 8.8 1.6 13.7 5.3 296 8 295 165 -7.2 0 -7 -7.2 03/18/2007 05:50:00 10.7 1.6 14.9 6.1 10.8 1.5 14.5 6.1 8.4 1.6 13.3 4.6 294 7 298 165 -7.2 0 -7 -7.4 03/18/2007 06:00:00 10.7 1.6 16.4 6.1 10.7 1.6 16.1 6.8 8.6 1.5 13.7 4.9 292 7 290 165 -7.2 0 -6.8 -7.4 03/18/2007 06:10:00 10.5 1.3 14.1 7.2 10.6 1.3 13.7 7.2 9 1.7 13 5.7 288 8 295 165 -7.2 0 -6.8 -7.4 03/18/2007 06:20:00 10.9 1.7 15.3 6.5 10.9 1.6 15.3 6.5 8.6 1.6 13.3 4.9 293 9 292 165 -7.3 0 -7 -7.4 03/18/2007 06:30:00 12 1.8 17.6 8 12 1.7 17.2 8 9.6 1.8 15.3 5.7 296 8 302 165 -7.2 0 -7 -7.4 03/18/2007 06:40:00 12.5 1.3 15.3 9.1 12.4 1.3 15.3 9.1 9.8 1.4 15.6 6.5 297 9 297 165 -7.2 0 -6.8 -7.2 03/18/2007 06:50:00 12 1.7 16.8 7.6 11.9 1.6 16.4 7.6 9.6 1.5 14.5 5.7 299 9 294 165 -7.2 0 -7 -7.4 03/18/2007 07:00:00 11.8 1.8 17.9 7.6 11.7 1.7 18.3 7.2 9.3 1.5 14.9 5.7 299 8 291 165 -7.2 0 -7 -7.4 03/18/2007 07:10:00 11.1 1.9 16.1 6.5 11 1.9 15.6 6.5 9.4 1.4 13 5.7 304 13 297 165 -7.2 0 -7 -7.2 03/18/2007 07:20:00 12.3 1.9 17.2 7.2 12.1 1.9 17.6 7.6 10.5 1.7 15.3 5.3 306 13 287 165 -7.1 0 -6.8 -7.2 03/18/2007 07:30:00 12 1.5 15.6 7.6 11.8 1.5 15.3 8 10.5 1.5 14.9 6.1 310 13 306 165 -7 0.1 -6.6 -7.4 03/18/2007 07:40:00 12.5 1.7 16.8 7.2 12.3 1.7 16.4 7.2 10.7 1.9 16.1 4.9 310 13 301 165 -6.6 0.1 -6.4 -6.8 03/18/2007 07:50:00 10.3 2.6 16.8 4.6 10.2 2.6 16.1 4.2 8 2.7 14.9 2.3 307 17 305 165 -6.4 0.1 -6.1 -6.8 03/18/2007 08:00:00 8.3 1.9 12.6 3 8.2 1.8 12.6 2.6 6.5 2.1 12.2 1.1 310 21 300 165 -6.1 0.1 -5.7 -6.6 03/18/2007 08:10:00 8.7 1.9 13.3 3.8 8.7 1.8 13.3 3.8 6.9 1.7 12.6 3 308 17 310 165 -5.8 0 -5.7 -6.1 03/18/2007 08:20:00 9.7 1.6 14.1 5.3 9.6 1.6 14.1 5.3 8.4 1.5 13.7 3.8 314 16 301 165 -5.7 0.1 -5.3 -5.7 03/18/2007 08:30:00 9.8 1.5 14.1 5.3 9.7 1.5 13.7 5.3 8.6 1.4 13 3.8 318 14 317 165 -5.3 0.1 -5 -5.7 03/18/2007 08:40:00 9.9 1.8 16.1 5.7 9.6 1.8 16.1 4.2 9.3 1.7 15.3 4.9 329 14 325 165 -5 0 -4.6 -5.3 03/18/2007 08:50:00 9.9 1.2 13.7 6.8 9.7 1.2 13.3 6.8 9.1 1.3 12.6 5.7 320 12 312 165 -4.8 0.1 -4.6 -5 03/18/2007 09:00:00 10.5 1.5 14.1 6.8 10.4 1.5 14.5 6.5 9.8 1.5 14.1 5.7 323 15 305 165 -4.7 0 -4.6 -4.8 03/18/2007 09:10:00 9.9 1.5 13.7 6.5 9.8 1.5 14.1 5.7 9.1 1.5 14.5 4.9 323 15 338 165 -4.6 0.1 -4.2 -5 03/18/2007 09:20:00 10.2 1.5 13.7 6.1 10 1.5 13.3 6.1 9 1.5 13 5.7 316 13 301 165 -4.4 0.1 -4.2 -4.6 03/18/2007 09:30:00 9.1 2 14.1 3.4 9 2 14.1 2.3 7.7 1.8 13.3 1.9 313 16 312 165 -4.3 0.1 -3.9 -4.6 03/18/2007 09:40:00 10.6 2.2 15.3 4.9 10.5 2.1 15.3 4.6 8.1 1.9 13.3 3.4 301 14 300 165 -4.3 0.1 -3.9 -5 03/18/2007 09:50:00 11.3 2 15.3 5.3 11.2 1.9 14.5 5.7 8.6 2 13 3.4 298 11 297 165 -4.2 0.2 -3.7 -4.8 03/18/2007 10:00:00 11.5 1.7 15.6 7.2 11.4 1.7 14.9 7.2 8.9 1.5 13.3 3 299 12 300 165 -4.4 0.2 -3.9 -4.6 03/18/2007 10:10:00 12.4 1.8 16.8 6.5 12.3 1.7 16.4 6.5 9.5 1.8 14.1 4.6 295 11 308 165 -4.4 0.2 -4.2 -5 03/18/2007 10:20:00 13.6 2 19.1 9.1 13.5 2 18.7 8.4 10.9 2.1 17.2 6.8 292 9 290 165 -4.8 0.3 -4.4 -5.3 03/18/2007 10:30:00 15.1 1.9 19.5 8.8 15 2 19.5 8 12.3 1.9 17.6 8 291 8 297 165 -5.3 0.1 -5 -5.9 03/18/2007 10:40:00 15.2 1.7 19.9 10.3 15.1 1.7 19.9 10.3 13 2 17.6 5.7 288 7 287 165 -5.3 0 -5 -5.5 03/18/2007 10:50:00 14 1.7 18.3 9.5 14 1.8 18.3 9.5 11.5 1.7 16.1 6.1 291 9 299 165 -5.2 0 -5 -5.5 03/18/2007 11:00:00 14.7 1.9 18.3 8 14.7 1.9 18.3 8 11.6 1.7 16.8 7.2 292 8 289 165 -5.2 0 -4.8 -5.5 03/18/2007 11:10:00 15.8 1.6 19.5 9.9 15.8 1.6 19.5 9.9 12 1.6 17.2 8.8 295 7 285 165 -5 0 -4.8 -5.5 03/18/2007 11:20:00 14.7 1.7 18.7 10.7 14.7 1.7 18.3 10.7 11.2 1.5 16.4 7.6 296 7 295 165 -4.9 0 -4.6 -5.3 03/18/2007 11:30:00 14.6 1.7 18.3 10.3 14.6 1.7 18.7 10.3 11.5 1.6 16.1 8 293 7 300 165 -4.8 0 -4.6 -5.3 03/18/2007 11:40:00 14.4 1.5 17.6 9.5 14.4 1.5 17.6 9.9 11.1 1.5 16.1 8 295 8 297 165 -4.7 0 -4.6 -5 03/18/2007 11:50:00 13.4 1.3 17.6 9.9 13.4 1.3 17.6 8.8 10.7 1.6 16.1 7.2 294 9 297 165 -4.7 0 -4.4 -4.6 03/18/2007 12:00:00 14.3 1.1 17.2 11.1 14.3 1.2 17.2 10.7 11.5 1.5 16.8 8.4 295 8 273 165 -4.5 0 -4.4 -4.6 03/18/2007 12:10:00 15.5 1.2 18.7 11.8 15.5 1.2 18.7 11.8 11.5 1.5 17.6 8.4 299 7 302 165 -4.5 0 -4.4 -4.8 03/18/2007 12:20:00 14.5 1 16.8 9.9 14.5 1 16.8 10.3 11.4 1.5 15.3 8.4 302 7 290 165 -4.4 0 -4.2 -4.6 03/18/2007 12:30:00 13.3 1.2 16.1 9.9 13.2 1.2 16.4 9.9 10.5 1.5 14.9 7.6 297 8 300 165 -4.3 0 -4.2 -4.6 03/18/2007 12:40:00 14 1.1 16.8 10.7 14 1.2 16.8 10.7 10.7 1.2 15.6 8.4 295 7 290 165 -4.3 0 -4.2 -4.6 03/18/2007 12:50:00 13.9 1.5 17.2 10.3 13.9 1.5 17.2 10.3 11.1 1.5 15.3 7.6 301 8 298 165 -4.2 0 -3.9 -4.6 03/18/2007 13:00:00 13.3 1.3 16.1 8.8 13.3 1.4 16.1 8.4 10.5 1.5 15.3 6.8 300 7 298 165 -4.2 0.1 -3.7 -4.4 03/18/2007 13:10:00 13.1 1.2 16.1 10.3 13.1 1.2 16.1 10.3 10.3 1.5 14.5 7.2 300 8 298 165 -4.1 0 -3.9 -4.4 03/18/2007 13:20:00 12.9 1.3 15.6 9.9 12.8 1.3 15.6 9.9 10.6 1.3 14.1 7.6 304 8 304 165 -4 0 -3.9 -4.4 03/18/2007 13:30:00 12.5 1.7 15.6 9.1 12.4 1.7 15.6 9.1 10.5 1.5 15.3 7.6 305 7 307 165 -4 0 -3.7 -4.2 03/18/2007 13:40:00 12.6 1.5 15.6 7.6 12.5 1.5 15.3 7.6 10.7 1.4 14.1 8 307 6 304 165 -3.7 0 -3.5 -3.9 03/18/2007 13:50:00 13.3 0.8 14.9 9.9 13.3 0.9 14.9 9.9 10.6 1.2 13.3 7.6 304 6 310 165 -3.9 0 -3.5 -4.2 03/18/2007 14:00:00 13.1 1.1 15.3 9.9 13 1.1 15.3 9.9 11.3 1.4 14.5 7.2 307 5 302 165 -3.9 0 -3.5 -4.2 03/18/2007 14:10:00 11.2 1.2 14.1 7.6 11.1 1.2 14.1 7.2 9.7 1.5 13 6.1 306 8 307 165 -3.7 0.1 -3.5 -4.2 03/18/2007 14:20:00 10.5 1.1 13.7 7.2 10.4 1.1 14.1 6.8 9.1 1.4 13.3 5.7 305 9 308 165 -3.7 0.1 -3.3 -4.2 03/18/2007 14:30:00 12.4 0.9 14.1 8.8 12.4 1 14.1 8.4 9.4 1.1 12.6 6.8 303 5 301 165 -3.8 0 -3.5 -4.4 03/18/2007 14:40:00 12.2 0.9 14.5 9.5 12.1 1 14.1 9.5 9.7 1.2 12.6 6.8 305 5 301 165 -3.8 0 -3.5 -4.2 03/18/2007 14:50:00 12.3 0.8 14.1 9.9 12.2 0.8 13.7 9.5 10 1.2 13 6.8 306 4 312 165 -3.8 0 -3.5 -4.2 03/18/2007 15:00:00 11.9 1.3 14.5 8.4 11.9 1.3 14.9 8.4 10.4 1.4 13.7 7.2 307 6 306 165 -3.8 0 -3.5 -4.2 03/18/2007 15:10:00 11.7 1.1 14.1 8.8 11.6 1.1 13.7 8.4 10 1.3 13 6.5 307 5 309 165 -3.7 0 -3.5 -3.9 03/18/2007 15:20:00 11.3 1.1 14.5 7.6 11.3 1.1 14.5 7.6 9.8 1.5 14.9 6.1 306 6 306 165 -3.8 0 -3.5 -4.2 03/18/2007 15:30:00 11.3 1.2 14.1 8 11.2 1.2 14.1 8.8 9.5 1.3 12.6 6.8 305 7 300 165 -3.7 0 -3.5 -3.9 03/18/2007 15:40:00 11.7 0.7 13.7 9.5 11.6 0.7 13.7 9.5 9.4 1.2 12.2 6.5 305 4 305 165 -3.8 0 -3.5 -4.2 03/18/2007 15:50:00 11 1 13.3 8 11 1 13.3 8 8.7 1 11.5 5.7 305 6 303 165 -3.8 0.1 -3.5 -4.2 03/18/2007 16:00:00 10.8 0.9 12.6 8 10.7 0.9 12.6 8 8.8 1.2 12.6 5.7 305 6 298 165 -3.8 0 -3.5 -4.2 03/18/2007 16:10:00 10.1 1 12.2 7.6 10 1 12.2 7.2 8.5 1.5 12.2 4.9 304 7 310 165 -3.9 0 -3.7 -4.2 03/18/2007 16:20:00 10.7 1.1 13.3 7.6 10.6 1.1 13 7.6 9.8 1.5 12.6 5.7 308 7 313 165 -3.8 0 -3.5 -4.2 03/18/2007 16:30:00 10.6 0.8 12.6 7.6 10.5 0.8 12.2 7.6 9.5 1 11.8 6.5 310 5 307 165 -3.8 0 -3.7 -4.2 03/18/2007 16:40:00 9.2 0.8 11.1 7.2 9.2 0.8 10.7 7.2 7.5 1.1 11.1 4.9 301 8 310 165 -3.9 0 -3.7 -4.2 03/18/2007 16:50:00 7.5 1.1 9.9 4.2 7.5 1.1 10.3 4.6 6.5 1.1 9.5 4.2 309 7 300 165 -3.6 0.2 -3.3 -3.9 03/18/2007 17:00:00 8.6 1 10.7 5.3 8.5 1 10.7 5.3 7.6 1 9.9 4.9 309 5 310 165 -3.5 0.1 -3.3 -3.9 03/18/2007 17:10:00 8.9 0.8 10.7 6.8 8.8 0.8 10.7 6.8 8.6 0.9 10.3 6.1 314 6 307 165 -3.7 0.1 -3.5 -3.9 03/18/2007 17:20:00 8.3 1 10.3 5.7 8.2 1 10.3 5.7 8.1 1 10.7 5.7 313 5 312 165 -3.7 0 -3.5 -3.9 03/18/2007 17:30:00 8.1 1.1 10.7 5.7 8 1.1 10.3 5.3 7.2 1.1 9.9 4.2 307 6 309 165 -3.9 0 -3.5 -4.2 03/18/2007 17:40:00 7.7 0.7 9.5 5.7 7.7 0.7 9.5 6.1 6.4 0.7 8.4 4.6 301 7 303 165 -4.1 0 -3.9 -4.4 03/18/2007 17:50:00 7.5 0.8 9.5 5.3 7.4 0.8 9.5 5.3 6.3 0.8 8.4 4.6 305 6 306 165 -4 0 -3.9 -4.2 03/18/2007 18:00:00 7.8 0.6 9.1 6.5 7.8 0.7 9.1 6.1 6.6 0.8 8.4 4.6 305 7 304 165 -4.2 0 -3.9 -4.4 03/18/2007 18:10:00 7.9 0.8 9.9 6.1 7.9 0.8 9.9 6.1 6.2 0.8 8 4.2 303 4 304 165 -4.4 0 -4.2 -4.6 03/18/2007 18:20:00 8.2 0.6 9.9 7.2 8.2 0.6 9.9 6.8 7.1 1 9.9 5.3 308 4 313 165 -4.5 0 -4.4 -4.6 03/18/2007 18:30:00 8.1 0.6 9.5 6.8 8.1 0.6 9.5 6.8 6.6 0.7 8.8 4.6 307 4 307 165 -4.7 0 -4.4 -4.8 03/18/2007 18:40:00 8.6 0.9 10.3 5.3 8.6 0.9 10.3 5.3 7.3 1.1 9.9 4.6 307 5 305 165 -4.8 0 -4.6 -5 03/18/2007 18:50:00 8.2 0.8 10.3 6.5 8.1 0.8 10.3 6.1 7.9 0.7 9.1 5.7 313 6 298 165 -4.8 0 -4.6 -5 03/18/2007 19:00:00 7.5 0.5 8.8 6.1 7.6 0.5 8.8 6.1 7 0.7 8.4 4.9 310 5 303 165 -5.1 0.2 -4.6 -5.5 03/18/2007 19:10:00 5.4 0.7 7.2 3.8 5.3 0.8 7.6 3 5.4 0.6 7.6 3.8 328 16 297 165 -5.5 0.2 -5.3 -5.7 03/18/2007 19:20:00 6.2 1.1 9.1 4.6 6.1 1.2 9.1 3.4 6.2 0.8 9.9 4.6 327 18 320 165 -5.7 0 -5.5 -5.7 03/18/2007 19:30:00 6.5 0.9 8.8 4.6 6.5 0.9 8.8 3.8 6.5 0.7 8.4 4.6 320 10 310 165 -5.8 0.1 -5.5 -5.9 03/18/2007 19:40:00 5.4 0.9 8.8 3.4 5.4 0.9 8.8 3 5.5 0.7 8 3.8 324 11 313 165 -5.9 0 -5.7 -6.1 03/18/2007 19:50:00 7 0.7 8.8 4.9 7.1 0.7 9.1 5.3 6.1 0.8 8.4 4.2 307 6 306 165 -5.9 0.1 -5.7 -6.4 03/18/2007 20:00:00 7.5 0.7 9.1 5.7 7.5 0.7 9.1 5.7 6.2 0.8 8 3.8 305 6 301 165 -5.9 0 -5.7 -6.1 03/18/2007 20:10:00 6.2 1 8.4 3 6.2 1 8.4 3.4 6 1 8.4 3.4 321 12 312 165 -5.9 0 -5.7 -6.1 03/18/2007 20:20:00 6.6 0.9 8.4 4.2 6.6 1 8.4 3.8 6.2 0.7 8 4.2 318 13 308 165 -6 0 -5.7 -6.4 03/18/2007 20:30:00 5.3 0.6 6.8 3.8 5.2 0.6 7.2 3.4 5.5 0.5 6.8 4.2 334 12 326 165 -6.2 0 -6.1 -6.6 03/18/2007 20:40:00 6 0.7 8 4.6 5.8 0.9 8.4 2.6 6.4 0.8 8.4 4.2 344 9 349 165 -6.4 0.1 -6.1 -6.6 03/18/2007 20:50:00 5.5 0.8 7.2 3.4 5.5 0.9 7.2 3.4 5.7 0.8 7.6 3.8 331 11 353 165 -6.4 0 -6.1 -6.6 03/18/2007 21:00:00 5.3 0.8 7.2 3.4 5.3 0.8 7.2 3 5 0.6 6.8 3.8 315 12 300 165 -6.4 0 -6.1 -6.6 03/18/2007 21:10:00 5.4 0.5 6.8 4.2 5.4 0.5 6.8 3.8 5.6 0.6 7.6 4.2 334 9 343 165 -6.4 0 -6.1 -6.8 03/18/2007 21:20:00 5.5 0.8 8.4 3.8 5.5 0.8 8.4 4.2 5.6 0.8 8 3.8 326 9 339 165 -6.6 0 -6.4 -6.8 03/18/2007 21:30:00 5.3 0.9 7.6 3.4 5.4 0.9 7.6 3.4 5.6 0.9 7.2 3.8 327 9 325 165 -6.7 0 -6.6 -7 03/18/2007 21:40:00 4.7 0.6 6.1 3.4 4.7 0.6 6.1 3 4.4 0.6 6.1 2.6 307 11 289 165 -6.8 0 -6.6 -6.8 03/18/2007 21:50:00 4.7 0.8 7.2 3 4.8 0.8 7.2 3 4.5 0.7 6.5 3 311 14 309 165 -6.7 0 -6.6 -7 03/18/2007 22:00:00 6 0.9 7.6 3 6 0.9 7.6 3.4 5.2 0.7 6.8 3 304 10 297 165 -6.9 0.1 -6.6 -7 03/18/2007 22:10:00 4.7 0.7 6.8 3 4.7 0.7 6.5 3 4.6 0.5 6.1 3 312 11 299 165 -7 0 -6.8 -7.2 03/18/2007 22:20:00 4.4 0.7 6.1 2.6 4.4 0.7 6.5 2.6 4.4 0.6 6.1 3 314 10 295 165 -7.3 0 -7 -7.4 03/18/2007 22:30:00 4.8 0.5 6.1 3.4 4.8 0.5 6.5 3.4 4.9 0.5 6.5 3.4 317 12 304 165 -7.2 0 -6.8 -7.4 03/18/2007 22:40:00 4.5 0.6 6.5 3 4.5 0.6 6.1 3 4.7 0.5 6.1 3.4 324 11 315 165 -7.3 0.1 -7 -7.4 03/18/2007 22:50:00 5 0.6 6.5 3.4 5 0.7 6.8 2.6 5.1 0.6 6.5 3.4 322 13 339 165 -7.3 0 -7 -7.6 03/18/2007 23:00:00 5.3 0.6 7.2 3.8 5.3 0.6 7.2 3.8 5 0.6 6.8 3.8 310 8 313 165 -7.4 0.1 -7.2 -7.6 03/18/2007 23:10:00 5.4 1 8.8 3 5.4 1 8.4 3 5.3 1 8.8 2.6 314 12 300 165 -7.3 0.1 -7 -7.4 03/18/2007 23:20:00 6.4 1.1 8.8 4.2 6.3 1.1 8.8 4.2 5.9 0.7 8.8 4.6 313 11 301 165 -7.4 0 -7.2 -7.6 03/18/2007 23:30:00 5.7 0.7 7.6 3.8 5.7 0.7 7.6 3.8 5.4 0.8 8.4 3 310 13 298 165 -7.5 0 -7.2 -7.6 03/18/2007 23:40:00 5.6 0.8 8 3.4 5.6 0.8 8.4 3.4 5.6 0.6 7.2 4.2 327 13 289 165 -7.6 0 -7.4 -7.6 03/18/2007 23:50:00 6 0.8 8.8 4.2 6.1 0.8 8.8 4.6 5.9 0.8 8.4 3.4 312 14 300 165 -7.5 0.1 -7.2 -8.1 03/19/2007 00:00:00 7.1 1 9.1 4.6 7.1 1 9.1 4.6 6.2 1 8.8 4.2 308 9 305 165 -7.6 0 -7.4 -7.9 03/19/2007 00:10:00 7.9 1 9.9 4.6 7.9 1 9.9 4.6 6.7 0.8 8.8 4.6 305 9 300 165 -7.6 0 -7.4 -7.9 03/19/2007 00:20:00 5.4 0.9 7.6 3.4 5.3 1 7.6 3.4 5.5 0.8 7.6 3.4 327 16 298 165 -7.9 0 -7.6 -8.1 03/19/2007 00:30:00 6.4 1.1 8.8 4.2 6.4 1 8.8 4.2 6.1 0.8 8 4.2 315 13 304 165 -7.7 0 -7.4 -8.1 03/19/2007 00:40:00 5.9 0.8 8 4.2 5.9 0.7 8 4.2 5.9 0.8 8.4 4.2 325 16 351 165 -7.7 0 -7.4 -8.1 03/19/2007 00:50:00 5.8 0.8 9.1 2.6 5.8 0.8 9.1 2.6 5.4 0.8 6.8 3.4 312 13 290 165 -7.6 0 -7.4 -7.9 03/19/2007 01:00:00 6 0.8 8 3.8 6 0.8 8.4 4.2 5.8 0.6 7.6 3.8 317 12 295 165 -7.8 0 -7.6 -8.1 03/19/2007 01:10:00 5.9 0.6 7.6 4.2 5.9 0.6 8 4.2 5.8 0.6 7.2 3.4 320 13 310 165 -7.8 0 -7.6 -8.1 03/19/2007 01:20:00 6.1 0.7 8 4.2 6.1 0.7 8 4.2 5.7 0.7 8 4.2 309 9 307 165 -7.9 0 -7.6 -8.1 03/19/2007 01:30:00 6.8 1 9.1 4.6 6.8 1 9.1 4.6 6.1 0.6 7.6 4.6 312 13 300 165 -8 0 -7.6 -8.1 03/19/2007 01:40:00 5.5 0.7 7.2 3.8 5.5 0.8 7.2 3.4 5.4 0.7 6.8 3.4 322 15 311 165 -8 0 -7.9 -8.3 03/19/2007 01:50:00 4.8 0.8 7.2 2.3 4.8 0.8 7.6 3 4.8 0.6 6.5 3 320 16 303 165 -8 0 -7.9 -8.3 03/19/2007 02:00:00 5.5 1 7.6 3.4 5.4 1.1 7.6 2.6 5.4 0.8 8.8 3.8 328 20 302 165 -8.1 0 -7.9 -8.3 03/19/2007 02:10:00 4.9 0.7 7.2 3 4.9 0.8 7.2 2.3 4.7 0.7 6.1 2.6 321 19 312 165 -8 0 -7.9 -8.1 03/19/2007 02:20:00 5.8 1.2 8.8 3 5.8 1.2 8.8 3.4 5.4 1 8.8 3.4 305 13 290 165 -8.1 0 -7.9 -8.3 03/19/2007 02:30:00 6.3 0.8 9.1 4.6 6.3 0.8 9.1 4.9 5.6 0.8 7.6 3.8 307 9 302 165 -8.2 0 -7.9 -8.5 03/19/2007 02:40:00 6.2 0.8 8 4.2 6 1 8.4 3.4 5.8 0.8 7.6 3.8 324 19 298 165 -8.2 0 -8.1 -8.5 03/19/2007 02:50:00 5.4 0.6 7.2 3.4 5.3 0.6 7.2 3.8 5.5 0.6 6.8 3.8 329 8 325 165 -8.3 0 -8.1 -8.5 03/19/2007 03:00:00 5.7 0.8 7.6 3.8 5.7 0.8 7.6 3.8 5.5 0.9 7.2 3 318 11 315 165 -8.2 0 -8.1 -8.5 03/19/2007 03:10:00 7.4 1 10.3 5.3 7.4 1 10.3 4.9 6.8 1 10.3 4.9 310 8 313 165 -8.2 0 -8.1 -8.5 03/19/2007 03:20:00 6.9 0.8 9.1 4.9 6.9 0.8 9.1 4.9 6.2 0.8 8.4 4.2 307 9 295 165 -8.2 0 -8.1 -8.5 03/19/2007 03:30:00 7.6 0.7 9.1 5.7 7.6 0.7 9.1 5.7 6.4 0.8 8.4 4.6 304 8 300 165 -8.4 0 -8.3 -8.7 03/19/2007 03:40:00 8.6 0.8 11.1 6.8 8.7 0.8 11.5 6.5 7.2 1.1 11.1 4.9 299 8 286 165 -8.4 0 -8.1 -8.5 03/19/2007 03:50:00 9 0.8 10.7 6.8 9 0.8 11.1 6.8 7.2 1.1 10.7 4.9 296 7 298 165 -8.4 0 -8.1 -8.5 03/19/2007 04:00:00 9 0.9 11.8 7.2 9.1 0.9 11.8 6.8 7.2 0.9 9.9 5.3 295 7 296 165 -8.7 0 -8.5 -8.9 03/19/2007 04:10:00 9 0.8 11.1 7.2 9.1 0.8 11.1 7.2 7.6 1.2 10.7 5.3 294 6 281 165 -8.6 0 -8.5 -8.9 03/19/2007 04:20:00 8.5 0.8 10.3 6.5 8.6 0.8 10.7 6.5 7.3 1.1 10.7 4.9 296 8 300 165 -8.7 0 -8.5 -8.9 03/19/2007 04:30:00 8.6 0.9 11.5 6.5 8.7 0.9 11.5 6.5 7.2 1 10.3 5.3 297 7 300 165 -9 0.1 -8.7 -9.1 03/19/2007 04:40:00 7.9 0.9 9.9 5.7 7.9 0.9 9.9 5.7 7.2 0.9 9.5 4.9 314 10 310 165 -9.1 0 -8.9 -9.3 03/19/2007 04:50:00 8.4 0.9 11.1 5.7 8.3 0.9 10.7 5.7 8 1 10.3 5.3 317 10 303 165 -9 0 -8.9 -9.1 03/19/2007 05:00:00 6.4 0.9 9.1 3.8 6.2 1.2 9.1 3 6.7 0.7 8.8 4.9 343 10 336 165 -9 0.1 -8.7 -9.3 03/19/2007 05:10:00 6.1 0.6 7.2 4.9 5.6 1.1 7.6 2.6 6.4 0.6 7.6 3.4 342 13 341 165 -9.2 0 -8.9 -9.5 03/19/2007 05:20:00 7.7 1.5 11.1 4.2 7.5 1.7 11.1 3 7.7 1.5 11.1 4.2 327 17 313 165 -9.2 0 -9.1 -9.7 03/19/2007 05:30:00 8.8 1.1 11.8 6.1 8.8 1.1 11.5 5.7 8.8 1.2 11.8 5.7 320 10 316 165 -9.1 0 -8.9 -9.3 03/19/2007 05:40:00 7.4 0.8 9.5 5.7 7.3 0.8 9.9 5.3 7.6 0.8 9.9 5.7 330 13 346 165 -9.2 0 -8.9 -9.3 03/19/2007 05:50:00 7.4 0.7 9.9 6.1 7.4 0.7 9.9 5.3 6.6 0.8 8.8 4.6 309 9 300 165 -9.3 0 -9.1 -9.5 03/19/2007 06:00:00 7.6 0.8 9.5 4.9 7.6 0.8 9.5 5.3 6.9 0.9 9.1 4.6 312 12 316 165 -9.2 0 -8.9 -9.7 03/19/2007 06:10:00 6.7 0.8 9.1 4.9 6.7 0.8 8.8 4.9 6.5 0.8 9.1 4.6 319 12 296 165 -9.3 0 -9.1 -9.7 03/19/2007 06:20:00 6.4 0.9 9.5 4.2 6.5 0.9 9.1 4.2 6.2 0.9 9.1 4.2 314 12 293 165 -9.3 0 -8.9 -9.7 03/19/2007 06:30:00 6.6 1 9.9 4.2 6.7 1 10.3 4.2 5.8 0.9 8.4 4.2 306 10 288 165 -9.5 0 -9.3 -9.7 03/19/2007 06:40:00 6.7 1.3 10.3 4.6 6.6 1.3 9.9 4.2 6.3 1 9.9 4.6 321 16 309 165 -9.4 0 -9.3 -9.7 03/19/2007 06:50:00 7 1 9.5 5.3 7 1 9.5 4.9 6.8 1 9.1 4.2 318 9 316 165 -9.6 0 -9.3 -9.7 03/19/2007 07:00:00 7 0.8 9.5 4.2 7 0.8 9.5 4.6 6.7 0.7 8.8 4.9 314 10 298 165 -9.5 0 -9.3 -9.7 03/19/2007 07:10:00 7.1 0.8 9.5 5.3 7.1 0.8 9.1 4.9 6.2 0.8 8.8 4.6 308 9 297 165 -9.5 0.1 -9.3 -9.7 03/19/2007 07:20:00 8.6 0.8 10.7 6.8 8.7 0.8 10.7 6.8 6.9 1 9.9 4.2 298 5 300 165 -9.5 0 -9.3 -9.7 03/19/2007 07:30:00 9 1.1 11.1 5.3 9.1 1.1 11.1 5.3 6.7 0.9 9.1 4.6 298 6 297 165 -9.4 0.1 -9.1 -9.7 03/19/2007 07:40:00 9.3 1 12.2 6.5 9.4 1 12.2 7.2 7.9 1.6 12.2 4.9 294 7 282 165 -9.3 0.1 -9.1 -9.5 03/19/2007 07:50:00 9.1 0.9 11.1 6.5 9.2 1 11.5 6.8 8.6 1 11.5 6.1 289 6 291 165 -9.1 0 -8.9 -9.3 03/19/2007 08:00:00 6.9 1.1 9.1 3.8 6.9 1.1 9.1 4.2 6.1 1 8.8 3.4 298 12 310 165 -8.7 0 -8.5 -9.3 03/19/2007 08:10:00 8 1.3 10.7 4.6 7.9 1.3 10.7 4.2 6.4 0.8 10.7 4.6 303 8 304 165 -8.5 0 -8.5 -8.9 03/19/2007 08:20:00 8.1 1.5 11.1 4.9 8.1 1.5 11.1 4.9 6.4 1.1 9.1 3.8 296 6 299 165 -8.7 0 -8.5 -8.9 03/19/2007 08:30:00 6.7 1.1 9.5 3.8 6.7 1.1 9.1 3.8 5.4 1.1 9.1 3 295 9 290 165 -8.6 0.1 -8.3 -9.1 03/19/2007 08:40:00 7 1.1 10.3 4.9 7 1.2 10.7 4.6 5.6 1 8.4 3.4 300 8 302 165 -8.2 0.1 -7.9 -8.5 03/19/2007 08:50:00 4.5 1.3 8.8 1.9 4.5 1.3 8.4 1.9 4 1.2 6.8 1.5 292 10 289 165 -7.7 0.1 -7.2 -8.1 03/19/2007 09:00:00 2.9 2 6.8 0.4 2.9 2.1 7.2 0.4 3.1 1.9 7.6 0.4 285 17 281 165 -7 0.2 -6.6 -7.6 03/19/2007 09:10:00 7.2 1.3 9.1 3.4 7.2 1.3 9.1 3.4 6.6 1.3 9.5 3 289 7 288 165 -7.9 0.2 -7.4 -8.1 03/19/2007 09:20:00 8.7 0.6 10.3 7.6 8.8 0.6 10.7 7.6 7.7 1.1 10.7 4.9 290 3 292 165 -8.4 0.1 -8.1 -8.5 03/19/2007 09:30:00 8.8 0.5 9.9 7.2 8.9 0.5 9.9 7.2 7 0.9 9.5 4.9 295 4 293 165 -8.3 0.1 -8.1 -8.5 03/19/2007 09:40:00 6.3 2.3 9.5 1.9 6.3 2.4 9.5 1.5 5.2 1.5 9.1 1.9 309 18 299 165 -7.4 0.5 -6.4 -8.1 03/19/2007 09:50:00 3.5 0.6 5.3 2.3 3.5 0.6 5.3 2.3 3.2 0.5 4.6 1.9 311 9 316 165 -6.3 0.1 -5.9 -6.6 03/19/2007 10:00:00 5.1 0.7 6.8 3.4 5.1 0.8 6.8 3.4 4.4 0.8 6.5 2.6 299 8 301 165 -6.8 0.3 -6.6 -7.6 03/19/2007 10:10:00 5.2 0.5 6.5 4.2 5.3 0.5 6.5 3.8 4.2 0.7 6.1 2.6 294 7 292 165 -6.7 0.2 -6.4 -7.2 03/19/2007 10:20:00 5 0.5 6.5 3.8 4.9 0.5 6.5 3.4 3.8 0.5 5.3 2.6 301 8 302 165 -6.5 0.1 -6.1 -6.8 03/19/2007 10:30:00 5.3 1 7.6 3.8 5.3 1 7.6 3.4 4.3 1 7.6 2.3 296 8 289 165 -6.4 0.1 -6.1 -7 03/19/2007 10:40:00 5.2 1.1 7.2 3 5.2 1.1 7.2 3 4.3 0.8 6.5 2.6 306 9 300 165 -6 0.3 -5.5 -6.6 03/19/2007 10:50:00 4.9 0.7 6.8 3 4.9 0.8 6.8 3 4.5 0.9 7.2 2.6 301 13 310 165 -5.4 0.3 -5 -6.1 03/19/2007 11:00:00 6.1 0.5 7.2 4.6 6.1 0.5 7.2 4.6 5.6 0.7 7.6 3.4 289 3 293 165 -6.5 0.1 -6.1 -6.8 03/19/2007 11:10:00 5.4 0.7 6.8 3.8 5.3 0.7 6.8 3.8 4.3 0.7 6.5 3 297 7 292 165 -6.5 0.1 -6.1 -6.8 03/19/2007 11:20:00 4.8 0.4 5.7 3.4 4.8 0.4 5.7 3.4 3.9 0.6 5.7 2.6 292 5 287 165 -6.2 0 -6.1 -6.6 03/19/2007 11:30:00 4.6 0.6 6.1 3 4.6 0.6 5.7 3 4.2 0.9 6.1 2.3 287 5 286 165 -6.1 0 -5.9 -6.1 03/19/2007 11:40:00 5.3 0.4 6.1 4.2 5.4 0.4 6.1 4.2 4.8 0.8 6.1 3 288 5 282 165 -6.2 0 -5.9 -6.4 03/19/2007 11:50:00 4.8 0.5 6.1 3 4.8 0.6 6.5 3 4.1 0.9 6.1 1.9 292 6 282 165 -6 0.1 -5.7 -6.4 03/19/2007 12:00:00 4.3 0.4 5.3 3.4 4.3 0.4 5.3 3 3.6 0.6 4.9 2.3 293 7 282 165 -5.8 0 -5.5 -6.1 03/19/2007 12:10:00 5.2 0.4 6.1 4.2 5.2 0.4 6.1 4.2 4.6 0.6 6.1 2.6 289 8 289 165 -5.5 0 -5.3 -5.7 03/19/2007 12:20:00 4.9 0.6 6.1 3.4 4.9 0.6 6.1 3 3.9 0.6 5.7 2.6 302 5 307 165 -5.4 0.1 -5 -5.7 03/19/2007 12:30:00 3.3 0.6 4.9 1.9 3.3 0.7 4.9 1.9 2.8 0.6 4.9 1.1 295 7 283 165 -4.9 0.2 -4.2 -5.5 03/19/2007 12:40:00 3.5 0.5 4.9 2.3 3.5 0.5 4.9 2.3 3.1 0.7 4.9 1.5 300 15 298 165 -4.7 0 -4.4 -5 03/19/2007 12:50:00 2.9 0.4 3.8 1.9 2.9 0.4 3.8 1.9 2.7 0.5 3.8 1.5 297 19 296 165 -4.2 0.2 -3.5 -4.6 03/19/2007 13:00:00 4.3 0.8 6.1 1.9 4.7 1 6.8 2.6 4.7 1.1 6.8 1.5 272 11 263 165 -4.2 0.2 -3.5 -4.6 03/19/2007 13:10:00 4.4 0.5 5.7 3 4.4 0.5 5.7 3 4.1 0.6 5.7 2.6 287 9 283 165 -4.8 0 -4.4 -5 03/19/2007 13:20:00 4.5 0.6 5.7 2.6 4.5 0.7 5.7 2.6 3.8 0.8 5.7 1.5 299 8 303 165 -4.8 0 -4.6 -5 03/19/2007 13:30:00 3.6 0.5 5.3 2.6 3.6 0.5 4.9 2.6 3.2 0.6 4.9 1.5 294 8 299 165 -4.7 0.1 -4.4 -4.8 03/19/2007 13:40:00 2.2 0.6 3.8 1.1 2.2 0.7 3.8 1.1 2.2 0.7 3.8 0.7 287 9 281 165 -4.1 0.3 -3.3 -4.6 03/19/2007 13:50:00 1.7 0.4 2.6 0.7 1.8 0.4 2.6 0.7 1.6 0.4 2.6 0.7 300 13 312 165 -3.3 0 -3 -3.5 03/19/2007 14:00:00 1.1 0.4 2.3 0.4 1.1 0.5 2.6 0.4 1.2 0.4 2.3 0.4 290 8 273 165 -2.8 0.2 -2.1 -3.3 03/19/2007 14:10:00 1.8 0.5 3 0.7 1.9 0.5 3 0.7 1.8 0.6 3 0.7 292 7 297 165 -3.2 0.3 -2.6 -3.7 03/19/2007 14:20:00 2.9 0.5 4.2 1.9 3 0.5 4.2 1.9 2.5 0.5 3.8 1.5 297 7 306 165 -3.7 0 -3.3 -3.9 03/19/2007 14:30:00 2.1 0.6 3.8 0.7 2.3 0.5 3.8 0.7 2.1 0.5 3.8 1.1 278 12 290 165 -3.6 0.4 -2.6 -4.2 03/19/2007 14:40:00 1.7 0.6 3 0.4 1.9 0.6 3 0.4 2 0.5 3.4 0.7 271 9 276 165 -2.9 0.1 -2.6 -3.3 03/19/2007 14:50:00 2.2 0.5 3.4 1.1 2.5 0.4 3.4 1.5 2.3 0.4 3 1.1 272 7 279 165 -2.7 0 -2.6 -3 03/19/2007 15:00:00 1.9 0.4 3 1.1 1.9 0.4 3 1.1 1.6 0.4 2.6 0.7 289 9 273 165 -2.9 0.2 -2.1 -3.3 03/19/2007 15:10:00 1.3 0.6 2.6 0.4 1.3 0.6 2.6 0.4 1.2 0.5 2.3 0.4 281 27 300 165 -2.2 0.1 -1.7 -2.6 03/19/2007 15:20:00 1.1 0.6 2.6 0.4 1.2 0.6 3 0.4 1 0.5 2.3 0.4 277 22 245 165 -1.8 0.3 -1 -2.4 03/19/2007 15:30:00 1.7 0.8 3.4 0.4 1.9 0.8 3.4 0.4 1.6 0.7 3.4 0.4 244 32 247 165 -1.8 0.1 -1.4 -2.1 03/19/2007 15:40:00 1.3 0.7 3.4 0.4 1.4 0.7 3.4 0.4 1.4 0.6 2.6 0.4 211 58 143 165 -1.7 0 -1.4 -2.1 03/19/2007 15:50:00 2.8 0.5 3.8 1.5 2.8 0.5 4.2 1.9 2.7 0.4 4.2 1.5 147 11 140 165 -2.1 0.3 -1.4 -2.6 03/19/2007 16:00:00 3.1 0.6 4.6 1.5 3.1 0.6 4.6 1.5 3.1 0.6 4.6 1.9 143 13 145 165 -2.7 0 -2.6 -3 03/19/2007 16:10:00 2.2 0.6 3.8 0.7 2.2 0.6 3.8 1.1 2.3 0.7 3.8 1.1 149 18 157 165 -2.8 0 -2.6 -3 03/19/2007 16:20:00 2.1 0.5 3.4 0.7 2.1 0.6 3.8 0.7 2 0.6 3.4 0.7 150 15 165 165 -2.9 0.1 -2.6 -3.5 03/19/2007 16:30:00 0.7 0.5 2.3 0.4 0.7 0.5 2.6 0.4 0.7 0.5 2.3 0.4 193 32 156 165 -2.1 0.6 -1.2 -3 03/19/2007 16:40:00 2.3 0.6 3.8 0.7 2.3 0.6 3.8 0.7 2.3 0.6 3.8 0.7 148 13 165 165 -2.2 0.6 -1.2 -3.3 03/19/2007 16:50:00 1.8 0.6 3.4 0.4 1.8 0.6 3.4 0.4 1.7 0.6 3.4 0.4 133 22 115 165 -3.1 0.2 -2.6 -3.5 03/19/2007 17:00:00 0.6 0.4 1.9 0.4 0.6 0.3 1.9 0.4 0.6 0.4 1.9 0.4 128 22 49 165 -2.9 0.6 -1.9 -3.9 03/19/2007 17:10:00 1.1 0.4 2.3 0.4 1.1 0.4 2.3 0.4 1.1 0.4 1.9 0.4 157 16 148 165 -2.6 0.2 -1.7 -3 03/19/2007 17:20:00 0.5 0.3 1.5 0.4 0.5 0.3 1.5 0.4 0.5 0.3 1.5 0.4 156 38 136 165 -2.4 0.1 -1.9 -2.8 03/19/2007 17:30:00 1 0.5 1.9 0.4 0.9 0.5 1.9 0.4 1 0.6 1.9 0.4 187 7 181 165 -2.8 0.3 -2.4 -3.3 03/19/2007 17:40:00 1.6 0.4 3 0.7 1.6 0.4 3 0.7 1.6 0.4 3 0.4 195 14 195 165 -3.2 0 -2.8 -3.3 03/19/2007 17:50:00 1.1 0.7 3 0.4 1.1 0.7 3 0.4 1.2 0.7 3 0.4 204 64 197 165 -2.9 0.2 -2.4 -3.3 03/19/2007 18:00:00 1.2 0.5 2.3 0.4 1.2 0.6 2.3 0.4 1.2 0.6 2.3 0.4 302 13 317 165 -2.8 0.5 -1.9 -3.7 03/19/2007 18:10:00 0.5 0.3 1.9 0.4 0.5 0.3 1.9 0.4 0.4 0.2 1.5 0.4 24 51 43 165 -3.7 0 -3.5 -3.9 03/19/2007 18:20:00 1.2 0.8 3 0.4 1.2 0.8 3 0.4 1.1 0.8 3.4 0.4 124 41 176 165 -3.6 0.1 -3 -3.9 03/19/2007 18:30:00 2.2 0.4 3 1.1 2.2 0.4 3 1.1 2.3 0.4 3 1.1 198 12 179 165 -4 0.1 -3.5 -4.6 03/19/2007 18:40:00 0.6 0.4 1.9 0.4 0.7 0.5 1.9 0.4 0.8 0.6 2.3 0.4 197 17 218 165 -4.5 0.1 -3.9 -4.6 03/19/2007 18:50:00 0.5 0.2 1.1 0.4 0.6 0.3 1.5 0.4 0.4 0.2 1.1 0.4 114 41 114 165 -4.6 0.1 -4.4 -4.8 03/19/2007 19:00:00 0.8 0.3 1.5 0.4 0.8 0.3 1.5 0.4 0.7 0.3 1.5 0.4 124 9 126 165 -5.2 0.2 -4.6 -5.9 03/19/2007 19:10:00 0.4 0 0.7 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 127 0 128 165 -5.6 0 -5.3 -6.1 03/19/2007 19:20:00 0.5 0.2 1.1 0.4 0.6 0.3 1.1 0.4 0.5 0.2 1.1 0.4 120 11 109 165 -5.5 0 -5.5 -5.7 03/19/2007 19:30:00 0.5 0.2 1.1 0.4 0.6 0.2 1.1 0.4 0.7 0.2 1.1 0.4 96 0 96 165 -5.5 0 -5.5 -5.7 03/19/2007 19:40:00 0.9 0.3 1.5 0.4 1.1 0.3 1.5 0.4 1.1 0.3 1.5 0.4 108 8 96 165 -5.8 0.1 -5.5 -6.1 03/19/2007 19:50:00 1.6 0.4 2.6 0.4 1.8 0.4 2.6 0.7 1.8 0.4 2.6 1.1 128 4 136 165 -5.9 0 -5.7 -5.9 03/19/2007 20:00:00 1.7 0.3 2.3 1.1 2 0.3 2.6 1.1 2 0.3 2.6 1.5 120 4 119 165 -5.8 0 -5.5 -5.9 03/19/2007 20:10:00 1.4 0.3 2.3 0.7 1.7 0.3 2.3 1.1 1.9 0.3 2.3 1.5 127 8 120 165 -5.7 0 -5.5 -5.7 03/19/2007 20:20:00 0.9 0.3 1.5 0.4 1.1 0.3 1.9 0.4 1.3 0.3 1.9 0.4 119 0 119 165 -5.8 0 -5.7 -5.9 03/19/2007 20:30:00 1.6 0.4 2.6 0.7 1.9 0.4 2.6 1.1 1.9 0.4 2.6 1.1 118 7 126 165 -5.9 0 -5.7 -6.1 03/19/2007 20:40:00 2 0.3 2.6 1.1 2.2 0.3 3 1.1 2.2 0.4 3.4 1.1 134 5 134 165 -5.8 0 -5.5 -5.9 03/19/2007 20:50:00 1.9 0.3 2.6 1.1 2.1 0.2 2.6 1.5 2.2 0.3 3 1.1 126 5 121 165 -5.8 0 -5.5 -5.9 03/19/2007 21:00:00 1.4 0.3 2.3 0.4 1.5 0.4 2.3 0.4 1.5 0.4 2.3 0.7 120 0 121 165 -5.8 0 -5.5 -5.9 03/19/2007 21:10:00 1.3 0.3 1.9 0.7 1.3 0.3 1.9 0.7 1.5 0.2 1.9 0.7 120 1 119 165 -5.9 0 -5.7 -6.1 03/19/2007 21:20:00 1.1 0.3 1.9 0.4 1 0.3 1.9 0.4 1.4 0.3 1.9 0.7 128 1 125 165 -5.9 0 -5.7 -6.1 03/19/2007 21:30:00 1 0.2 1.5 0.7 0.9 0.3 1.5 0.4 1.1 0.3 1.5 0.7 128 0 128 165 -5.9 0 -5.7 -6.1 03/19/2007 21:40:00 1.2 0.2 1.5 0.7 1.1 0.2 1.5 0.7 1.4 0.2 1.9 0.7 131 3 128 165 -6.1 0 -5.9 -6.4 03/19/2007 21:50:00 1.1 0.2 1.5 0.4 0.8 0.3 1.5 0.4 1.5 0.2 1.9 1.1 144 6 134 165 -6.4 0.1 -6.1 -6.6 03/19/2007 22:00:00 0.7 0.3 1.1 0.4 0.4 0.1 0.7 0.4 0.8 0.4 1.5 0.4 157 0 156 165 -6.4 0 -6.1 -6.6 03/19/2007 22:10:00 0.9 0.5 1.9 0.4 0.6 0.4 1.5 0.4 0.8 0.4 1.9 0.4 157 0 157 165 -6.3 0.1 -6.1 -6.8 03/19/2007 22:20:00 0.9 0.3 1.5 0.4 0.5 0.3 1.1 0.4 1 0.4 1.9 0.4 157 0 157 165 -6.6 0 -6.1 -6.8 03/19/2007 22:30:00 1.1 0.4 1.9 0.4 0.8 0.5 1.9 0.4 1.4 0.4 2.3 0.7 159 3 164 165 -6.2 0.1 -5.9 -6.6 03/19/2007 22:40:00 1.3 0.3 2.3 0.4 1 0.4 1.9 0.4 1.7 0.2 2.3 1.1 176 5 176 165 -5.9 0 -5.7 -6.1 03/19/2007 22:50:00 0.6 0.4 1.9 0.4 0.5 0.3 1.5 0.4 1.2 0.4 2.3 0.4 179 3 179 165 -5.9 0 -5.7 -6.1 03/19/2007 23:00:00 1.9 0.3 2.6 1.1 1.6 0.4 2.3 0.7 2.2 0.4 2.6 1.1 180 6 184 165 -6 0 -5.7 -6.1 03/19/2007 23:10:00 1.1 0.4 1.9 0.4 0.8 0.4 1.9 0.4 1.5 0.3 2.3 0.7 168 6 177 165 -5.9 0 -5.7 -6.1 03/19/2007 23:20:00 0.5 0.3 1.1 0.4 0.4 0 0.4 0.4 1 0.4 1.5 0.4 168 0 168 165 -5.9 0 -5.7 -6.1 03/19/2007 23:30:00 1.1 0.2 1.9 0.7 0.5 0.2 1.5 0.4 1.5 0.2 1.9 1.1 173 3 173 165 -6 0 -5.7 -6.1 03/19/2007 23:40:00 1.6 0.4 2.3 0.7 1.3 0.5 2.3 0.4 2 0.4 2.6 1.1 174 2 175 165 -6 0 -5.7 -6.1 03/19/2007 23:50:00 2.2 0.3 2.6 1.5 2 0.3 2.6 1.5 2.4 0.3 3 1.9 169 2 165 165 -5.9 0 -5.7 -6.1 03/20/2007 00:00:00 2.5 0.3 3.4 1.9 2.4 0.3 3 1.9 2.8 0.3 3.8 2.3 169 4 166 165 -5.8 0 -5.5 -5.9 03/20/2007 00:10:00 2.3 0.3 3 1.5 2.1 0.4 3 1.1 2.6 0.3 3.4 1.9 173 8 173 165 -5.8 0 -5.5 -5.7 03/20/2007 00:20:00 2.5 0.4 3.8 1.9 2.4 0.4 3.4 1.5 2.7 0.4 3.8 1.9 179 4 180 165 -5.8 0 -5.7 -5.9 03/20/2007 00:30:00 2.2 0.4 3 1.5 2 0.5 3 0.7 2.4 0.4 3.4 1.5 169 6 176 165 -5.9 0 -5.7 -6.1 03/20/2007 00:40:00 2.1 0.3 3 1.1 1.7 0.4 2.6 0.7 2.2 0.3 3 1.5 172 8 174 165 -5.9 0 -5.7 -6.1 03/20/2007 00:50:00 1.9 0.3 2.6 1.5 1.4 0.4 2.6 0.7 2.2 0.3 3 1.9 180 2 182 165 -6 0 -5.7 -6.1 03/20/2007 01:00:00 2.1 0.3 2.6 1.1 1.7 0.4 2.6 0.7 2.3 0.3 3 1.5 175 5 182 165 -5.9 0 -5.7 -6.4 03/20/2007 01:10:00 1.1 0.4 2.3 0.4 0.5 0.4 2.3 0.4 1.3 0.5 2.6 0.4 169 4 177 165 -6.1 0 -5.7 -6.4 03/20/2007 01:20:00 1.7 0.5 2.3 0.4 1.1 0.6 2.3 0.4 1.7 0.6 2.6 0.4 173 3 174 165 -6 0 -5.7 -6.4 03/20/2007 01:30:00 1.3 0.3 2.3 0.7 0.6 0.4 1.9 0.4 1.5 0.3 2.6 1.1 165 0 168 165 -6 0 -5.7 -6.1 03/20/2007 01:40:00 1 0.2 1.5 0.7 0.4 0 0.4 0.4 1.3 0.2 1.9 0.7 163 1 164 165 -6.2 0.1 -5.9 -6.6 03/20/2007 01:50:00 1 0.4 1.9 0.4 0.6 0.3 1.5 0.4 1.4 0.3 1.9 0.7 146 8 147 165 -6.4 0.1 -6.1 -6.8 03/20/2007 02:00:00 0.5 0.2 1.5 0.4 0.4 0 0.7 0.4 0.6 0.2 1.1 0.4 140 0 140 165 -6.6 0 -6.4 -6.8 03/20/2007 02:10:00 0.6 0.2 1.1 0.4 0.4 0 0.4 0.4 0.6 0.2 1.1 0.4 140 0 141 165 -7.1 0 -6.8 -7.4 03/20/2007 02:20:00 0.5 0.3 1.5 0.4 0.4 0.1 1.1 0.4 0.6 0.3 1.1 0.4 136 18 65 165 -7.3 0 -7 -7.4 03/20/2007 02:30:00 0.7 0.3 1.1 0.4 0.4 0.1 0.7 0.4 0.9 0.4 1.9 0.4 43 8 65 165 -7 0.1 -6.8 -7.2 03/20/2007 02:40:00 0.7 0.4 1.9 0.4 0.4 0.2 1.5 0.4 1 0.3 1.9 0.4 100 27 129 165 -6.6 0.2 -6.1 -7 03/20/2007 02:50:00 1.1 0.3 1.9 0.4 0.8 0.4 1.5 0.4 1.4 0.3 1.9 0.7 138 9 129 165 -6.4 0 -6.1 -6.6 03/20/2007 03:00:00 1.3 0.3 1.9 0.7 1.3 0.3 1.9 0.4 1.7 0.3 2.3 0.7 118 5 119 165 -6.5 0 -6.4 -6.8 03/20/2007 03:10:00 1.5 0.3 2.3 0.7 1.6 0.3 2.3 0.7 2 0.3 2.6 1.5 114 0 114 165 -6.4 0 -6.1 -6.8 03/20/2007 03:20:00 1.5 0.4 2.3 0.7 1.5 0.4 2.3 0.4 2 0.3 2.6 1.1 120 3 115 165 -6.4 0 -6.1 -6.6 03/20/2007 03:30:00 1 0.2 1.5 0.4 0.9 0.3 1.5 0.4 1.5 0.3 1.9 0.7 99 10 94 165 -6.5 0 -6.4 -6.6 03/20/2007 03:40:00 1.3 0.5 2.3 0.4 1.2 0.5 2.3 0.4 1.8 0.4 2.6 0.7 123 9 116 165 -6.4 0.1 -6.1 -6.8 03/20/2007 03:50:00 1.5 0.5 2.6 0.4 1.3 0.5 2.6 0.4 1.8 0.4 2.6 0.7 132 6 140 165 -6.4 0 -6.1 -6.6 03/20/2007 04:00:00 2.3 0.3 3 1.9 2.2 0.3 3 1.5 2.6 0.3 3.4 1.9 140 3 137 165 -6.1 0 -6.1 -6.4 03/20/2007 04:10:00 2.6 0.4 3.4 1.9 2.5 0.4 3.4 1.9 2.9 0.3 3.8 2.3 149 4 147 165 -6.1 0 -5.9 -6.4 03/20/2007 04:20:00 2.3 0.4 3 1.1 2.1 0.4 3 1.1 2.6 0.3 3.4 1.9 144 4 148 165 -6 0 -5.9 -6.4 03/20/2007 04:30:00 1.9 0.6 2.6 0.4 1.6 0.7 2.6 0.4 2.1 0.5 3 1.1 155 6 160 165 -6 0 -5.7 -6.1 03/20/2007 04:40:00 1.8 0.4 2.6 1.1 1.5 0.5 2.3 0.7 2.2 0.4 3 1.5 155 8 157 165 -6 0 -5.9 -6.1 03/20/2007 04:50:00 2.7 0.3 3.8 1.9 2.6 0.3 3.4 1.9 3 0.2 3.4 2.3 154 5 153 165 -6 0 -5.7 -6.1 03/20/2007 05:00:00 2.1 0.4 3 1.1 1.8 0.6 3 0.4 2.2 0.5 3 1.5 157 5 155 165 -5.9 0 -5.7 -6.1 03/20/2007 05:10:00 2.1 0.5 3.4 1.1 1.7 0.7 3 0.4 2.1 0.6 3.4 1.1 158 6 165 165 -5.9 0.1 -5.5 -6.1 03/20/2007 05:20:00 3.1 0.4 3.8 1.9 2.9 0.4 3.4 1.9 3.3 0.5 3.8 1.9 162 4 165 165 -5.6 0 -5.5 -5.7 03/20/2007 05:30:00 2.3 0.3 3 1.5 1.9 0.3 2.6 1.1 2.3 0.2 2.6 1.9 157 3 156 165 -5.6 0 -5.5 -5.9 03/20/2007 05:40:00 2.2 0.2 2.6 1.9 1.6 0.3 2.3 1.1 2.2 0.2 2.6 1.5 155 2 156 165 -5.6 0 -5.5 -5.9 03/20/2007 05:50:00 1.7 0.4 2.6 1.1 1 0.5 2.3 0.4 1.7 0.4 2.6 1.1 142 4 150 165 -5.4 0 -5 -5.7 03/20/2007 06:00:00 1.8 0.3 2.6 1.1 1.6 0.4 2.3 0.7 1.9 0.2 2.3 1.1 120 9 116 165 -5.3 0 -5 -5.5 03/20/2007 06:10:00 2.3 0.3 3 1.5 2.1 0.3 3 1.1 2.5 0.3 3 1.5 121 5 123 165 -5.2 0 -5 -5.5 03/20/2007 06:20:00 2.5 0.2 3 1.5 2.4 0.3 3 1.5 2.7 0.2 3 2.3 124 7 115 165 -5 0 -4.8 -5.3 03/20/2007 06:30:00 2.9 0.4 3.8 2.3 2.8 0.5 3.8 1.9 2.9 0.3 3.8 2.3 123 2 124 165 -4.9 0 -4.6 -5.3 03/20/2007 06:40:00 3.2 0.3 4.2 1.9 3.3 0.4 4.2 1.5 3.1 0.4 4.2 2.3 113 6 111 165 -4.7 0 -4.4 -5 03/20/2007 06:50:00 3.2 0.4 4.2 2.3 3.2 0.4 4.6 2.3 3.3 0.4 4.9 2.3 114 7 104 165 -4.2 0.1 -3.9 -4.6 03/20/2007 07:00:00 4 0.6 5.3 2.6 4.2 0.6 5.3 3 3.9 0.6 5.3 2.3 107 5 112 165 -4.1 0 -3.9 -4.4 03/20/2007 07:10:00 6.4 0.9 8 4.6 6.5 0.9 8 4.9 6.1 0.9 8 4.2 110 4 114 165 -3.8 0.2 -3.3 -4.2 03/20/2007 07:20:00 6.9 0.5 8.4 5.3 7 0.6 8.8 5.3 6.7 0.5 7.6 4.9 111 5 104 165 -3.3 0 -3 -3.5 03/20/2007 07:30:00 7.1 0.4 8 6.1 7.2 0.4 8 6.1 6.9 0.5 8.4 4.9 112 3 115 165 -3.2 0.1 -3 -3.5 03/20/2007 07:40:00 6.8 0.7 8 4.2 6.9 0.7 8 4.6 6.7 0.8 8 4.2 111 5 105 165 -3.1 0 -2.8 -3.3 03/20/2007 07:50:00 7.1 0.6 8.8 5.3 7.2 0.6 9.1 5.3 6.9 0.6 8.4 4.6 118 6 116 165 -3 0 -2.8 -3.3 03/20/2007 08:00:00 6.9 0.7 8.8 4.9 6.9 0.7 8.8 4.9 6.8 0.5 8 5.3 125 5 133 165 -3.2 0.1 -2.8 -3.5 03/20/2007 08:10:00 6.2 0.6 7.6 4.6 6.2 0.6 7.6 4.9 6 0.5 8 4.6 121 4 119 165 -3.5 0.2 -3 -3.9 03/20/2007 08:20:00 7.2 0.6 8.4 5.7 7.3 0.5 8.4 5.7 7.1 0.5 8.4 5.7 123 5 121 165 -3 0 -2.8 -3.3 03/20/2007 08:30:00 6.9 0.7 8.4 4.9 6.9 0.6 8.8 4.9 6.7 0.6 8.4 5.3 129 7 126 165 -3 0.1 -2.8 -3.3 03/20/2007 08:40:00 7.6 1.2 9.9 3.8 7.7 1.2 9.9 4.2 7.3 1 9.5 4.9 131 5 135 165 -3 0 -2.6 -3.3 03/20/2007 08:50:00 7.6 0.7 9.1 5.7 7.7 0.6 9.1 6.1 7.4 0.6 9.1 5.7 124 6 135 165 -2.8 0 -2.6 -3 03/20/2007 09:00:00 8.6 0.9 10.7 6.5 8.7 0.8 10.7 6.8 8.3 0.8 9.9 6.1 123 4 119 165 -2.5 0.1 -2.1 -2.8 03/20/2007 09:10:00 8.5 1 10.7 5.7 8.6 1 10.7 6.1 8.3 1.1 10.7 5.7 121 5 121 165 -2.4 0.1 -2.1 -2.8 03/20/2007 09:20:00 10.3 0.8 12.6 8 10.4 0.8 12.6 8 10.2 0.9 13 7.6 121 4 115 165 -2 0.1 -1.9 -2.1 03/20/2007 09:30:00 10.3 0.7 12.2 8.4 10.4 0.8 12.2 8.4 10.1 0.7 12.2 8 123 4 125 165 -1.8 0 -1.7 -2.1 03/20/2007 09:40:00 11.1 0.8 13 8.8 11.2 0.8 13 8.8 10.9 0.8 13 8 125 4 121 165 -1.5 0.1 -1.2 -1.9 03/20/2007 09:50:00 11.1 1.3 14.9 8.8 11.3 1.3 14.9 9.1 11.1 1.3 15.3 8.4 124 5 122 165 -1.4 0 -1.2 -1.4 03/20/2007 10:00:00 12.2 1.1 15.3 9.9 12.4 1.1 15.3 9.9 12.1 1.1 14.9 9.9 124 7 122 165 -1 0 -0.8 -1.2 03/20/2007 10:10:00 14 1.5 18.3 10.3 14.2 1.5 17.9 10.7 13.9 1.5 18.7 10.3 126 7 133 165 -0.7 0 -0.5 -1 03/20/2007 10:20:00 13.2 2.5 17.9 7.2 13.5 2.5 17.9 7.6 13.3 2.5 17.9 8.4 132 9 129 165 -0.6 0.1 -0.3 -0.8 03/20/2007 10:30:00 15.3 2 19.9 10.3 15.4 1.9 19.9 10.3 15.5 2.1 20.2 9.9 131 7 133 165 -0.3 0 -0.3 -0.5 03/20/2007 10:40:00 16.6 1.4 20.2 13 16.6 1.4 19.9 12.6 16.7 1.6 20.6 11.5 135 8 139 165 -0.3 0 -0.1 -0.5 03/20/2007 10:50:00 15.5 2 19.9 10.3 15.6 2 19.9 10.3 15.7 2.3 20.2 10.3 130 8 128 165 -0.3 0 -0.1 -0.5 03/20/2007 11:00:00 15.8 1.7 19.5 11.1 16 1.7 19.9 11.1 16.1 1.7 20.2 11.8 132 7 124 165 -0.3 0 -0.1 -0.5 03/20/2007 11:10:00 15.1 1.5 19.1 11.5 15.3 1.6 19.5 11.5 15.2 1.7 19.9 10.3 126 7 118 165 -0.2 0 -0.1 -0.3 03/20/2007 11:20:00 14.7 1.4 20.2 12.2 14.9 1.4 21 12.2 15 1.5 20.6 10.7 130 7 118 165 -0.2 0 -0.1 -0.3 03/20/2007 11:30:00 14.4 1.5 18.7 11.5 14.6 1.5 18.7 11.5 14.6 1.5 18.7 11.1 127 8 117 165 -0.2 0 -0.1 -0.3 03/20/2007 11:40:00 14.8 1.4 18.7 11.5 15 1.5 19.1 11.5 15 1.5 19.1 10.7 124 7 128 165 -0.1 0 0.2 -0.3 03/20/2007 11:50:00 14.5 1.2 18.7 11.5 14.7 1.3 18.3 11.1 14.4 1.4 17.9 10.7 120 7 129 165 -0.1 0 -0.1 -0.3 03/20/2007 12:00:00 14 1.7 19.1 9.5 14.2 1.7 19.5 9.9 14.1 1.6 19.1 9.1 121 7 116 165 -0.1 0 0.2 -0.3 03/20/2007 12:10:00 14.3 1.7 19.5 9.9 14.5 1.7 19.9 9.9 14.1 1.9 20.6 9.9 118 6 124 165 -0.1 0 0.2 -0.1 03/20/2007 12:20:00 14.3 1.5 17.9 9.9 14.5 1.5 18.3 9.9 14.2 1.6 18.7 9.1 117 6 118 165 0.1 0 0.2 -0.1 03/20/2007 12:30:00 14.7 2 19.5 9.9 14.8 2 19.5 9.9 14.5 2.1 19.5 9.5 116 5 114 165 0.1 0 0.2 -0.1 03/20/2007 12:40:00 14.5 1.5 18.7 9.9 14.6 1.4 18.3 9.9 14.4 1.6 18.7 9.9 114 7 121 165 0.1 0 0.2 -0.1 03/20/2007 12:50:00 15.2 1.5 20.2 11.8 15.2 1.6 19.9 11.8 15 1.7 19.9 10.3 113 7 115 165 0.1 0 0.2 -0.1 03/20/2007 13:00:00 15 1.7 19.5 10.3 15 1.7 19.9 10.3 15 1.8 20.6 10.7 105 0 105 165 0.1 0 0.2 -0.1 03/20/2007 13:10:00 15.1 2.1 20.6 10.3 15 2.1 20.6 9.9 14.9 2.3 20.2 9.5 105 0 105 165 0.2 0 0.2 -0.1 03/20/2007 13:20:00 15.6 1.9 19.5 9.9 15.5 1.9 19.5 9.1 15.4 2.1 20.6 9.9 105 0 105 165 0.2 0 0.4 0.2 03/20/2007 13:30:00 15.5 1.8 19.9 10.3 15.4 1.7 19.9 10.3 15.6 1.8 20.6 10.3 105 0 106 165 0.2 0 0.4 0.2 03/20/2007 13:40:00 15.1 1.7 19.1 9.9 14.9 1.7 19.1 9.5 15.2 1.8 19.9 11.1 105 0 106 165 0.2 0 0.4 0.2 03/20/2007 13:50:00 14.4 1.5 18.7 10.3 14.2 1.5 18.3 10.3 14.3 1.6 17.9 9.9 106 0 106 165 0.2 0 0.4 0.2 03/20/2007 14:00:00 13.7 1.8 18.3 8.4 13.6 1.8 18.3 9.1 13.6 1.7 17.9 9.9 106 0 106 165 0.3 0 0.7 0.2 03/20/2007 14:10:00 13.4 1.3 17.2 8.4 13.4 1.3 17.2 8.4 13.5 1.3 17.6 8.8 106 0 106 165 0.4 0 0.7 0.2 03/20/2007 14:20:00 13.5 1.2 16.1 10.3 13.5 1.2 16.4 10.3 13.6 1.3 16.4 9.9 106 0 106 165 0.5 0 0.7 0.2 03/20/2007 14:30:00 12.7 1.5 16.1 8 12.7 1.5 16.1 7.6 12.8 1.6 16.1 8.4 106 0 106 165 0.5 0 0.7 0.2 03/20/2007 14:40:00 12.4 1.3 15.3 8.8 12.4 1.4 14.9 8.8 12.6 1.3 15.6 9.5 106 0 106 165 0.4 0 0.7 0.2 03/20/2007 14:50:00 12.8 1 15.3 10.3 12.7 1 15.3 9.9 12.9 1.1 15.6 9.9 106 0 106 165 0.5 0 0.7 0.2 03/20/2007 15:00:00 12.4 1 15.6 9.9 12.3 0.9 15.3 9.9 12.4 0.9 15.6 9.9 106 0 106 165 0.5 0 0.7 0.2 03/20/2007 15:10:00 12.7 1.1 15.6 9.1 12.5 1.1 15.3 9.5 12.7 1.2 15.3 9.1 106 0 106 165 0.5 0 0.7 0.2 03/20/2007 15:20:00 11.1 1.2 14.5 8.4 11 1.2 14.1 8.4 11.1 1.3 14.9 8 106 0 106 165 0.5 0 0.7 0.4 03/20/2007 15:30:00 10.9 1.1 14.1 8.4 10.8 1.1 14.5 8.8 10.9 1.1 14.1 8.8 106 0 106 165 0.5 0 0.7 0.4 03/20/2007 15:40:00 10.8 1 13 8 10.8 1 13 7.6 11 1 13.3 8 106 0 106 165 0.6 0 0.9 0.4 03/20/2007 15:50:00 10.1 1.2 14.1 7.6 9.9 1.3 13.7 6.5 9.9 1.5 14.1 6.8 106 0 106 165 0.8 0.1 0.9 0.7 03/20/2007 16:00:00 9.5 1 13 6.8 8.7 1 11.8 6.1 9 1.1 12.2 6.5 105 0 106 165 0.8 0 1.1 0.7 03/20/2007 16:10:00 8.3 1.1 11.1 5.7 7.3 1.1 10.3 4.6 7.4 1.2 10.7 4.6 105 0 106 165 0.8 0 0.9 0.7 03/20/2007 16:20:00 8.1 0.7 9.5 6.5 7 0.7 8.4 5.3 7.3 0.8 9.5 4.9 105 0 106 165 0.7 0 0.9 0.7 03/20/2007 16:30:00 8 0.9 10.3 5.7 6.7 0.8 8.8 4.6 7.4 1 10.3 4.6 105 0 106 165 0.8 0 0.9 0.7 03/20/2007 16:40:00 7.1 0.8 9.1 4.9 5.4 0.8 7.2 3 6.2 0.9 8.8 4.6 105 0 106 165 0.8 0 0.9 0.7 03/20/2007 16:50:00 6.7 0.8 9.1 4.6 5.3 1 7.6 2.6 5.7 1 8 3 105 0 106 165 0.9 0 1.1 0.7 03/20/2007 17:00:00 5.6 0.7 7.2 3.8 3.5 1 5.7 1.5 4.4 0.8 6.1 2.6 105 0 106 165 1.1 0 1.4 0.9 03/20/2007 17:10:00 4.7 1 6.5 2.3 1.2 1.2 4.2 0.4 3.4 1 5.7 1.1 105 0 106 165 1.1 0 1.4 0.9 03/20/2007 17:20:00 3.7 0.5 4.9 2.3 0.4 0 0.4 0.4 0.4 0.1 1.1 0.4 105 0 106 165 1.2 0 1.4 1.1 03/20/2007 17:30:00 3.3 0.5 4.6 1.9 0.4 0 0.4 0.4 0.4 0 0.4 0.4 105 0 106 165 1.3 0 1.4 1.4 03/20/2007 17:40:00 0.7 0.9 3.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 105 0 105 165 1.4 0 1.6 1.4 03/20/2007 17:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 105 0 165 165 1.4 0 1.6 1.4 03/20/2007 18:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 105 0 165 165 1.4 0 1.6 1.4 03/20/2007 18:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 105 0 165 165 1.4 0 1.6 1.4 03/20/2007 18:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 105 0 165 165 1.4 0 1.6 1.4 03/20/2007 18:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 105 0 165 165 1.4 0 1.4 1.4 03/20/2007 18:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 105 0 165 165 1.4 0 1.4 1.4 03/20/2007 18:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 105 0 165 165 1.4 0 1.6 1.1 03/20/2007 19:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 105 0 165 165 1.4 0 1.6 1.4 03/20/2007 19:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 105 0 165 165 1.4 0 1.6 1.4 03/20/2007 19:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 105 0 165 165 1.4 0 1.6 1.4 03/20/2007 19:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 105 0 165 165 1.4 0 1.6 1.4 03/20/2007 19:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 105 0 165 165 1.4 0 1.6 1.4 03/20/2007 19:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 105 0 165 165 1.4 0 1.6 1.4 03/20/2007 20:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 105 0 165 165 1.3 0 1.4 1.1 03/20/2007 20:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 105 0 165 165 1.4 0 1.6 1.4 03/20/2007 20:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 105 0 165 165 1.4 0 1.6 1.4 03/20/2007 20:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 105 0 165 165 1.4 0 1.6 1.4 03/20/2007 20:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 105 0 165 165 1.5 0 1.6 1.4 03/20/2007 20:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 105 0 165 165 1.5 0 1.6 1.4 03/20/2007 21:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 105 0 165 165 1.5 0 1.6 1.4 03/20/2007 21:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 105 0 165 165 1.4 0 1.6 1.4 03/20/2007 21:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 105 0 165 165 1.5 0 1.6 1.4 03/20/2007 21:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 105 0 165 165 1.5 0 1.6 1.4 03/20/2007 21:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 105 0 165 165 1.5 0 1.6 1.4 03/20/2007 21:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 105 0 165 165 1.5 0 1.6 1.4 03/20/2007 22:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 105 0 165 165 1.5 0 1.6 1.4 03/20/2007 22:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 105 0 165 165 1.5 0 1.6 1.4 03/20/2007 22:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 105 0 165 165 1.5 0 1.6 1.4 03/20/2007 22:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 105 0 165 165 1.5 0 1.6 1.4 03/20/2007 22:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 105 0 165 165 1.4 0 1.6 1.1 03/20/2007 22:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 105 0 165 165 1.3 0 1.4 1.4 03/20/2007 23:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 105 0 165 165 1.3 0 1.4 1.1 03/20/2007 23:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 105 0 165 165 1.2 0 1.4 1.1 03/20/2007 23:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 105 0 165 165 1.1 0 1.4 0.9 03/20/2007 23:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 105 0 165 165 1.1 0 1.4 0.9 03/20/2007 23:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 105 0 165 165 1.1 0 1.4 0.9 03/20/2007 23:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 105 0 165 165 1.2 0 1.4 0.9 03/21/2007 00:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 105 0 165 165 1.3 0 1.4 1.1 03/21/2007 00:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 105 0 165 165 1.4 0 1.6 1.4 03/21/2007 00:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 105 0 165 165 1.4 0 1.6 1.4 03/21/2007 00:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 105 0 165 165 1.4 0 1.6 1.4 03/21/2007 00:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 105 0 165 165 1.4 0 1.6 1.4 03/21/2007 00:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 105 0 165 165 1.2 0 1.4 0.9 03/21/2007 01:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 105 0 165 165 1.2 0 1.4 0.9 03/21/2007 01:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 105 0 165 165 1.2 0 1.4 1.1 03/21/2007 01:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 105 0 165 165 1.2 0 1.4 0.9 03/21/2007 01:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 105 0 165 165 1.3 0 1.4 1.1 03/21/2007 01:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 105 0 165 165 1.3 0 1.6 1.4 03/21/2007 01:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 105 0 165 165 1.2 0 1.4 0.9 03/21/2007 02:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 105 0 165 165 1.1 0 1.4 0.9 03/21/2007 02:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 105 0 165 165 1.1 0 1.4 0.9 03/21/2007 02:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 105 0 165 165 0.9 0 1.4 0.9 03/21/2007 02:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 105 0 165 165 1 0 1.1 0.9 03/21/2007 02:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 105 0 165 165 1 0 1.1 0.9 03/21/2007 02:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 105 0 165 165 1.1 0 1.4 0.9 03/21/2007 03:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 105 0 165 165 1.1 0 1.4 0.9 03/21/2007 03:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 105 0 165 165 1.1 0 1.4 0.9 03/21/2007 03:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 105 0 165 165 1.1 0 1.4 0.9 03/21/2007 03:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 105 0 165 165 1.1 0 1.4 0.9 03/21/2007 03:40:00 0.4 0.2 1.9 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 105 0 105 165 1.2 0 1.4 0.9 03/21/2007 03:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 105 0 165 165 1.1 0 1.4 0.9 03/21/2007 04:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 105 0 165 165 1 0 1.4 0.9 03/21/2007 04:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 105 0 165 165 0.9 0 1.1 0.9 03/21/2007 04:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 105 0 165 165 0.9 0 1.1 0.9 03/21/2007 04:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 105 0 165 165 0.8 0 1.1 0.9 03/21/2007 04:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 105 0 165 165 0.8 0 0.9 0.7 03/21/2007 04:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 105 0 165 165 0.8 0 0.9 0.7 03/21/2007 05:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 105 0 165 165 0.8 0 0.9 0.7 03/21/2007 05:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 105 0 165 165 0.8 0 0.9 0.7 03/21/2007 05:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 105 0 165 165 0.8 0 0.9 0.7 03/21/2007 05:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 105 0 165 165 0.8 0 0.9 0.7 03/21/2007 05:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 105 0 165 165 0.8 0 0.9 0.7 03/21/2007 05:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 105 0 165 165 0.8 0 0.9 0.7 03/21/2007 06:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 105 0 165 165 0.7 0 0.9 0.4 03/21/2007 06:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 105 0 165 165 0.5 0 0.7 0.2 03/21/2007 06:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 105 0 165 165 0.3 0 0.7 0.2 03/21/2007 06:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 105 0 165 165 0.2 0 0.4 0.2 03/21/2007 06:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 105 0 165 165 0.3 0 0.7 0.2 03/21/2007 06:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 105 0 165 165 0.2 0 0.7 0.2 03/21/2007 07:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 105 0 165 165 0.2 0 0.4 0.2 03/21/2007 07:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 105 0 165 165 0.2 0 0.4 0.2 03/21/2007 07:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 105 0 165 165 0.2 0 0.4 0.2 03/21/2007 07:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 105 0 165 165 0.2 0 0.4 -0.1 03/21/2007 07:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 105 0 165 165 0.2 0 0.4 -0.1 03/21/2007 07:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 105 0 165 165 0 0 0.2 -0.1 03/21/2007 08:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 105 0 165 165 -0.1 0 -0.1 -0.3 03/21/2007 08:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 105 0 165 165 -0.1 0 0.2 -0.3 03/21/2007 08:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 105 0 165 165 -0.1 0 -0.1 -0.3 03/21/2007 08:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 105 0 165 165 -0.1 0 -0.1 -0.3 03/21/2007 08:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 105 0 165 165 -0.1 0 -0.1 -0.3 03/21/2007 08:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 105 0 165 165 -0.1 0 0.2 -0.1 03/21/2007 09:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 105 0 165 165 0.1 0 0.2 -0.1 03/21/2007 09:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 105 0 165 165 0.1 0 0.2 -0.1 03/21/2007 09:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 105 0 165 165 -0.1 0 0.2 -0.3 03/21/2007 09:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 105 0 165 165 -0.3 0.1 -0.1 -0.5 03/21/2007 09:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 105 0 165 165 -0.5 0 -0.3 -0.8 03/21/2007 09:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 105 0 165 165 -0.9 0.1 -0.5 -1.2 03/21/2007 10:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 105 0 165 165 -1.3 0.1 -1.2 -1.4 03/21/2007 10:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 105 0 165 165 -1.5 0 -1.4 -1.7 03/21/2007 10:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 105 0 165 165 -1.7 0 -1.4 -1.9 03/21/2007 10:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 105 0 165 165 -1.6 0 -1.4 -1.9 03/21/2007 10:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 105 0 165 165 -1.6 0 -1.4 -1.7 03/21/2007 10:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 105 0 165 165 -1.5 0 -1.4 -1.7 03/21/2007 11:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 105 0 165 165 -1.3 0 -1.2 -1.4 03/21/2007 11:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 105 0 165 165 -1.1 0 -1 -1.2 03/21/2007 11:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 105 0 165 165 -0.9 0 -0.8 -1.2 03/21/2007 11:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 105 0 165 165 -0.8 0 -0.5 -1 03/21/2007 11:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 105 0 165 165 -0.4 0.2 0.2 -0.8 03/21/2007 11:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 105 0 165 165 0 0.3 0.4 -0.5 03/21/2007 12:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 105 0 165 165 -0.3 0.1 -0.1 -0.8 03/21/2007 12:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 105 0 165 165 0.5 0.3 1.1 -0.1 03/21/2007 12:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 106 0 165 165 -0.2 0.1 0.2 -0.8 03/21/2007 12:30:00 0.4 0 0.7 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 106 0 106 165 0.1 0.4 0.9 -0.8 03/21/2007 12:40:00 2.6 1.7 5.7 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 105 1 106 165 0.7 0.1 0.9 0.4 03/21/2007 12:50:00 4.7 1.5 7.6 1.5 0.4 0 0.4 0.4 0.4 0 0.4 0.4 106 0 106 165 0.2 0.3 0.9 -0.3 03/21/2007 13:00:00 3.5 1 6.1 1.5 0.4 0 0.4 0.4 0.4 0 0.4 0.4 106 0 106 165 -0.5 0.2 -0.1 -1.2 03/21/2007 13:10:00 5.2 0.8 6.8 3.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 105 1 104 165 -1.1 0.1 -0.8 -1.7 03/21/2007 13:20:00 6.9 0.7 8.4 5.7 0.4 0 0.4 0.4 0.4 0 0.4 0.4 106 0 106 165 -1 0.2 -0.5 -1.7 03/21/2007 13:30:00 6.2 0.6 8 4.9 0.4 0 0.4 0.4 0.4 0 0.4 0.4 106 0 106 165 -1.7 0.1 -1.4 -2.4 03/21/2007 13:40:00 4.5 0.9 6.1 2.3 0.4 0 0.4 0.4 0.4 0 0.4 0.4 106 1 106 165 -1.4 0.2 -1.2 -2.1 03/21/2007 13:50:00 4.6 1.4 7.6 1.9 0.4 0 0.4 0.4 0.4 0 0.4 0.4 105 1 106 165 -1.2 0 -0.8 -1.4 03/21/2007 14:00:00 4.7 0.8 6.8 2.6 0.4 0 0.4 0.4 0.4 0 0.4 0.4 105 1 106 165 -1.3 0 -1 -1.4 03/21/2007 14:10:00 5.3 1.3 8 3 0.4 0 0.4 0.4 0.4 0 0.4 0.4 106 1 106 165 -1 0 -0.8 -1.4 03/21/2007 14:20:00 6.1 0.9 8 4.2 0.4 0 0.4 0.4 0.4 0 0.4 0.4 106 1 106 165 -1.2 0.1 -0.8 -1.4 03/21/2007 14:30:00 6.3 0.8 8 4.2 0.4 0 0.4 0.4 0.4 0 0.4 0.4 105 1 106 165 -0.9 0.1 -0.8 -1.2 03/21/2007 14:40:00 7.1 0.8 8.8 4.9 0.4 0 0.4 0.4 1.7 2.7 9.1 0.4 105 1 106 165 -1 0 -0.5 -1.2 03/21/2007 14:50:00 7.6 0.9 9.5 5.3 0.4 0 0.4 0.4 6.3 1.1 9.1 4.2 104 1 105 165 -1.2 0 -0.8 -1.7 03/21/2007 15:00:00 6.7 1 9.5 4.2 0.4 0 0.4 0.4 6 1 9.5 3.8 104 2 101 165 -1.4 0.1 -1 -1.9 03/21/2007 15:10:00 5.1 1.2 8 2.6 0.4 0 0.4 0.4 5.7 1.5 9.1 2.6 104 1 105 165 -1.1 0.2 -0.8 -1.7 03/21/2007 15:20:00 4.3 1.2 6.8 1.5 0.4 0 0.4 0.4 4.8 1.3 8.4 1.5 105 1 105 165 -0.9 0.1 -0.5 -1.4 03/21/2007 15:30:00 2.2 1.2 4.6 0.4 0.4 0 0.4 0.4 2.6 1.1 4.9 0.4 105 1 105 165 -1 0.2 -0.5 -1.4 03/21/2007 15:40:00 3.5 0.8 6.1 1.5 0.4 0 0.4 0.4 3.4 0.7 5.3 1.9 105 1 106 165 -1.4 0.1 -1 -2.1 03/21/2007 15:50:00 4.3 1 6.1 1.5 0.4 0 0.4 0.4 4.4 1.2 6.8 2.3 105 1 105 165 -1.8 0.1 -1.4 -2.4 03/21/2007 16:00:00 4.2 0.6 6.1 3 0.4 0 0.4 0.4 3.8 0.8 6.5 2.3 105 0 105 165 -2.4 0.2 -1.9 -2.8 03/21/2007 16:10:00 5.1 0.8 8 3 0.4 0 0.4 0.4 5 1.1 7.6 3 105 0 105 165 -2.4 0.2 -2.1 -3 03/21/2007 16:20:00 4.9 1 7.2 2.6 0.4 0 0.4 0.4 4.7 1.3 7.6 2.3 105 0 105 165 -2.4 0.2 -1.9 -3 03/21/2007 16:30:00 3.1 1.1 4.9 0.4 0.4 0 0.4 0.4 2.9 0.7 4.6 1.5 105 0 105 165 -2.8 0.1 -2.6 -3.5 03/21/2007 16:40:00 3.4 0.8 5.7 1.9 0.4 0 0.4 0.4 3.9 0.7 5.7 2.3 105 0 105 165 -2.8 0 -2.6 -3.3 03/21/2007 16:50:00 3.2 0.6 4.9 1.5 0.4 0 0.4 0.4 4.1 0.5 5.7 2.6 105 0 105 165 -3 0 -2.8 -3 03/21/2007 17:00:00 3.9 0.6 5.3 2.3 0.4 0 0.4 0.4 4.2 0.8 6.5 2.6 105 0 105 165 -2.9 0 -2.6 -3 03/21/2007 17:10:00 4.1 0.9 6.1 1.9 0.4 0 0.4 0.4 4.2 1 6.5 1.5 105 0 105 165 -3 0.1 -2.8 -3.3 03/21/2007 17:20:00 5.3 0.8 6.8 3.4 0.4 0 0.4 0.4 5.1 0.9 7.2 3.4 104 0 105 165 -3.4 0 -3 -3.5 03/21/2007 17:30:00 7.4 0.9 9.5 5.3 0.4 0 0.4 0.4 6.5 1.1 9.1 4.2 193 98 301 165 -3.9 0.2 -3.5 -4.4 03/21/2007 17:40:00 7.1 0.7 9.1 4.9 0.4 0 0.4 0.4 6.1 0.8 8.4 4.6 299 7 294 165 -4.4 0 -4.2 -4.6 03/21/2007 17:50:00 6.8 0.7 8.4 4.9 0.4 0 0.4 0.4 6 0.8 8.8 3.8 295 7 296 165 -4.5 0 -4.4 -4.6 03/21/2007 18:00:00 6.1 0.8 8.4 4.2 0.4 0 0.4 0.4 6.4 0.9 9.1 3.8 285 7 291 165 -4.4 0 -4.4 -4.6 03/21/2007 18:10:00 6.4 1.3 8.8 3.8 0.4 0 0.4 0.4 7 1.3 9.5 4.2 276 7 286 165 -4.5 0 -4.4 -4.6 03/21/2007 18:20:00 7.4 1 9.5 4.2 0.4 0 0.4 0.4 8.2 0.8 9.5 5.7 272 5 270 165 -4.8 0 -4.4 -5 03/21/2007 18:30:00 7.6 1 9.5 4.6 0.4 0 0.4 0.4 7.8 0.8 9.1 4.2 278 7 274 165 -4.9 0 -4.6 -5 03/21/2007 18:40:00 7.7 0.8 9.5 5.3 0.4 0 0.4 0.4 7.1 1.2 9.1 4.2 289 9 294 165 -5 0 -4.8 -5.3 03/21/2007 18:50:00 5.8 1 8.4 3 0.4 0 0.4 0.4 5.1 1 7.6 2.6 300 9 302 165 -5 0 -5 -5.3 03/21/2007 19:00:00 3.6 0.8 5.7 1.5 0.4 0 0.4 0.4 3.1 0.8 5.7 1.5 299 10 295 165 -5.2 0 -5 -5.3 03/21/2007 19:10:00 4.4 1 6.5 1.5 1.9 2.3 6.5 0.4 3.9 1 6.5 1.5 292 14 302 165 -4.9 0.1 -4.6 -5.3 03/21/2007 19:20:00 2.7 0.7 4.6 1.1 3.3 0.9 5.7 1.5 3.1 0.9 5.7 1.1 274 20 253 165 -4.8 0.1 -4.6 -5 03/21/2007 19:30:00 1.7 1 4.2 0.4 2 1.2 4.6 0.4 1.9 1.1 4.6 0.4 271 24 277 165 -4.8 0 -4.6 -5 03/21/2007 19:40:00 3.5 0.9 6.5 1.1 4.2 1 7.2 1.9 3.9 0.9 6.8 1.9 264 15 280 165 -4.9 0 -4.6 -5 03/21/2007 19:50:00 4.6 1.3 8.4 2.3 5.4 1.4 9.1 2.3 5.1 1.3 8.8 2.6 264 17 285 165 -4.8 0.1 -4.6 -5.3 03/21/2007 20:00:00 6.2 1.4 9.5 3 6.8 1.4 9.5 3.8 6 1.3 8.8 3.4 283 11 291 165 -4.7 0 -4.4 -5 03/21/2007 20:10:00 4.1 0.9 6.5 2.3 4.8 1 7.2 2.6 4.4 1 6.8 2.3 276 12 284 165 -4.8 0 -4.6 -5 03/21/2007 20:20:00 3.4 1.2 6.8 0.7 3.9 1.3 6.8 0.7 4.1 1.2 7.2 1.9 254 14 244 165 -4.8 0 -4.6 -4.8 03/21/2007 20:30:00 3.7 1 6.5 1.9 4.2 1 7.2 2.3 3.8 1 6.1 1.9 276 15 288 165 -5 0 -4.6 -5.3 03/21/2007 20:40:00 5 1.3 8.4 1.9 5.7 1.3 9.1 2.6 5 1.2 7.6 2.6 274 12 282 165 -5.1 0 -4.6 -5.3 03/21/2007 20:50:00 5.2 1.3 7.6 2.3 6 1.1 8.4 3.4 5.5 1.1 7.6 3 266 13 242 165 -4.9 0 -4.6 -5.3 03/21/2007 21:00:00 3.1 1 5.7 0.7 3.4 1.1 7.2 0.7 3.3 1.1 6.8 0.7 278 26 275 165 -5 0 -4.8 -5.3 03/21/2007 21:10:00 2.3 0.9 4.6 0.4 2.8 1 5.3 0.7 2.7 0.8 4.9 0.7 265 15 250 165 -5 0 -4.8 -5.3 03/21/2007 21:20:00 2.3 0.7 4.2 0.7 2.7 0.8 4.6 0.7 2.8 0.7 4.6 1.1 255 13 259 165 -5.2 0.1 -5 -5.5 03/21/2007 21:30:00 1 0.7 2.6 0.4 1.2 0.7 3 0.4 1.2 0.6 2.6 0.4 114 61 148 165 -5.3 0 -5.3 -5.5 03/21/2007 21:40:00 1.4 0.8 3.4 0.4 1.7 0.8 3.8 0.4 1.8 0.7 3.4 0.4 97 30 115 165 -5.3 0 -5 -5.5 03/21/2007 21:50:00 1.4 0.9 4.2 0.4 1.9 0.9 4.6 0.4 2 1 4.6 0.4 167 64 106 165 -5.4 0.2 -5 -5.7 03/21/2007 22:00:00 0.8 0.5 2.3 0.4 1 0.6 2.6 0.4 1.1 0.8 2.6 0.4 338 53 344 165 -5.3 0.1 -5 -5.5 03/21/2007 22:10:00 1.7 0.8 3.4 0.4 2.1 0.8 3.8 0.4 2.1 0.8 3.8 0.4 315 14 325 165 -5.7 0.1 -5.5 -5.9 03/21/2007 22:20:00 3.1 1.1 4.9 0.7 3.4 1.1 5.3 0.7 2.9 0.8 4.6 1.1 310 8 307 165 -6 0 -5.7 -6.1 03/21/2007 22:30:00 4.4 0.6 6.1 3 4.8 0.6 6.5 3.4 4.2 0.7 6.1 2.6 309 5 310 165 -6 0 -5.7 -6.1 03/21/2007 22:40:00 4.7 0.6 6.5 3 5.1 0.6 6.8 3.4 4.2 0.9 6.5 2.6 305 9 314 165 -5.9 0 -5.7 -6.4 03/21/2007 22:50:00 4.6 0.5 5.7 3 5 0.5 6.1 3.8 3.6 0.5 4.9 2.6 300 5 298 165 -5.9 0 -5.7 -6.1 03/21/2007 23:00:00 4.8 0.9 6.8 3 5.2 0.9 7.6 3.4 4 0.9 6.8 1.9 302 7 303 165 -6.2 0.2 -5.7 -6.4 03/21/2007 23:10:00 5.6 0.7 7.2 3.8 6 0.8 7.6 4.2 4.2 0.6 5.7 3 299 4 297 165 -6.4 0 -6.1 -6.6 03/21/2007 23:20:00 5.7 0.7 7.6 3.8 6.1 0.7 8 4.6 5.3 1 8 3.4 308 7 296 165 -6.6 0 -6.4 -6.8 03/21/2007 23:30:00 5.4 0.8 8 3.8 5.8 0.8 8 4.2 4.7 0.8 7.6 2.6 297 7 297 165 -6.5 0 -6.4 -6.8 03/21/2007 23:40:00 5.2 0.8 7.2 3.8 5.5 0.8 7.6 3.8 4.6 1 7.6 2.6 304 9 302 165 -6.9 0.1 -6.6 -7.2 03/21/2007 23:50:00 4.1 0.6 5.7 3 4.6 0.6 6.1 3.4 4.4 0.8 6.8 2.3 290 11 284 165 -6.6 0.2 -6.4 -6.8 03/22/2007 00:00:00 4 0.5 5.7 2.6 4.5 0.5 6.1 3.4 4.4 0.7 6.1 2.3 281 7 292 165 -6.5 0 -6.4 -6.6 03/22/2007 00:10:00 4.3 0.5 5.7 3 4.7 0.5 6.5 3.4 3.9 0.7 5.7 2.3 291 7 272 165 -6.7 0.1 -6.4 -6.8 03/22/2007 00:20:00 5.2 0.6 6.8 3.8 5.6 0.7 7.2 4.6 4.3 0.6 6.5 3 301 6 300 165 -7 0 -6.8 -7.2 03/22/2007 00:30:00 4.8 0.9 6.5 2.6 5.1 0.9 6.8 3 4.2 0.9 6.1 2.3 303 8 302 165 -6.7 0 -6.4 -7 03/22/2007 00:40:00 6.7 1.3 9.5 4.9 7.1 1.3 10.7 5.3 5.7 1.2 9.1 3.8 300 7 295 165 -6.8 0 -6.6 -6.8 03/22/2007 00:50:00 7.1 1.3 9.1 4.2 7.3 1.3 9.5 4.2 5.5 0.8 7.2 3.4 301 6 300 165 -7.1 0 -6.6 -7.2 03/22/2007 01:00:00 3.5 0.9 6.5 1.9 3.7 0.9 6.5 1.9 2.6 0.8 5.3 0.7 303 20 287 165 -7.6 0.1 -7.2 -8.1 03/22/2007 01:10:00 1.9 1 4.6 0.4 2.2 1 4.6 0.4 2.3 0.8 3.8 0.7 302 47 302 165 -7.3 0.3 -6.8 -8.1 03/22/2007 01:20:00 1.6 0.8 3.8 0.4 2.1 0.8 4.2 0.4 2.1 0.9 4.9 0.4 267 22 288 165 -7 0 -6.8 -7.2 03/22/2007 01:30:00 3.3 0.7 4.9 1.1 3.7 0.7 5.3 2.3 3.7 0.7 5.7 1.9 276 7 282 165 -7.1 0 -6.8 -7.4 03/22/2007 01:40:00 4.2 0.6 6.5 3.4 4.6 0.7 6.8 3.8 4.5 0.5 6.5 3.4 281 6 289 165 -7.3 0 -7 -7.6 03/22/2007 01:50:00 5.6 1.1 7.6 3.8 6 1.1 7.6 4.2 4.7 0.7 7.2 3.4 292 9 292 165 -7.4 0.1 -7.2 -7.6 03/22/2007 02:00:00 5.9 0.9 8 3.4 6.1 0.9 8 3.8 5.2 1 7.6 2.6 300 12 302 165 -7.2 0.2 -6.8 -7.6 03/22/2007 02:10:00 4.5 1.7 7.6 1.9 4.6 1.7 7.6 1.9 4.2 1.3 7.6 1.9 320 13 312 165 -8 0.1 -7.6 -8.3 03/22/2007 02:20:00 4 1.5 6.8 1.5 4.2 1.6 6.8 1.5 3.4 1.1 5.7 1.5 310 15 303 165 -8 0.3 -7.4 -8.5 03/22/2007 02:30:00 5.7 0.5 7.2 4.2 5.9 0.5 7.2 4.6 4.6 0.6 6.5 3.4 302 5 297 165 -7.3 0 -7 -7.6 03/22/2007 02:40:00 5.6 0.5 6.8 4.2 5.8 0.6 7.2 4.6 4.5 0.7 6.5 3 298 6 297 165 -7.2 0 -6.8 -7.4 03/22/2007 02:50:00 5.3 0.6 6.5 3.8 5.5 0.6 6.8 3.8 4.5 0.8 6.8 2.6 295 7 300 165 -7.4 0 -7 -7.6 03/22/2007 03:00:00 5.6 0.5 6.8 4.6 5.7 0.5 7.2 4.6 4.3 0.5 5.7 3 301 5 300 165 -7.4 0.1 -7 -7.4 03/22/2007 03:10:00 5.1 0.4 6.1 4.2 5.2 0.4 6.5 4.2 4.4 0.6 5.7 3 293 5 295 165 -7.4 0 -7.2 -7.6 03/22/2007 03:20:00 4.6 0.7 6.1 2.6 4.7 0.7 6.1 3 3.9 0.7 6.5 1.9 298 7 292 165 -7.3 0.1 -7 -7.6 03/22/2007 03:30:00 3.8 0.6 6.1 2.6 3.8 0.6 6.1 2.3 3.4 0.6 5.3 2.3 311 16 281 165 -7.6 0.1 -7.2 -7.9 03/22/2007 03:40:00 4.5 0.6 5.7 3 4.6 0.6 5.7 3 4.6 0.7 6.1 3 318 12 299 165 -7.6 0.1 -7.2 -8.1 03/22/2007 03:50:00 4.4 0.4 5.3 3 4.5 0.4 5.3 3 4.4 0.5 5.7 2.6 317 11 306 165 -7.1 0 -6.8 -7.4 03/22/2007 04:00:00 3.5 0.5 4.6 2.3 3.5 0.6 4.9 2.3 3.6 0.4 4.6 2.6 324 9 333 165 -7.5 0.2 -7.2 -8.1 03/22/2007 04:10:00 2.5 0.5 4.2 1.5 2.6 0.4 3.8 1.5 2.7 0.4 4.2 1.9 325 10 313 165 -7.9 0.1 -7.6 -8.3 03/22/2007 04:20:00 3.2 0.6 4.6 1.9 3.4 0.6 4.9 1.9 3 0.5 4.2 1.9 309 10 299 165 -7.8 0.3 -7.2 -8.5 03/22/2007 04:30:00 3.2 0.4 4.2 2.3 3.3 0.4 4.2 2.3 2.8 0.4 3.8 1.9 299 8 296 165 -7.5 0.2 -7.2 -8.1 03/22/2007 04:40:00 3.2 0.6 4.6 1.9 3.3 0.6 4.6 1.9 2.8 0.5 4.6 1.9 305 16 293 165 -8.2 0.2 -7.6 -8.7 03/22/2007 04:50:00 4.1 0.7 5.3 2.3 4.2 0.7 5.3 2.3 3.5 0.5 4.9 2.3 300 9 294 165 -7.8 0.2 -7.4 -8.5 03/22/2007 05:00:00 3.2 0.9 5.7 1.1 3.1 1 5.7 1.1 3.3 0.7 5.3 1.9 339 26 307 165 -8.2 0.2 -7.9 -8.7 03/22/2007 05:10:00 3.5 0.6 4.9 2.3 2.7 1.1 4.9 1.1 3.9 0.6 5.3 3 353 13 334 165 -8.8 0.1 -8.3 -9.1 03/22/2007 05:20:00 4.1 0.8 5.7 2.6 4.1 1 6.5 2.3 4.5 0.9 6.5 2.6 345 5 346 165 -8.8 0 -8.5 -8.9 03/22/2007 05:30:00 2.9 0.3 3.8 2.3 3.1 0.3 3.8 1.9 3.3 0.3 4.2 2.6 331 8 331 165 -8.7 0.1 -8.5 -9.1 03/22/2007 05:40:00 3 0.4 4.2 1.9 2.6 0.9 4.2 0.7 3.3 0.3 4.2 2.3 340 20 307 165 -8.5 0.1 -8.1 -8.7 03/22/2007 05:50:00 2.8 0.3 3.8 1.9 2.9 0.3 3.8 1.9 2.7 0.5 3.8 1.1 308 9 302 165 -7.8 0.1 -7.6 -8.1 03/22/2007 06:00:00 2.7 0.6 3.8 0.7 2.8 0.6 3.8 1.1 2.6 0.5 4.2 1.5 299 8 289 165 -8 0 -7.9 -8.3 03/22/2007 06:10:00 3.2 1.1 4.9 1.1 3.3 1 4.9 1.1 3.2 0.8 5.3 1.5 290 9 282 165 -8 0.1 -7.6 -8.3 03/22/2007 06:20:00 2.9 0.6 4.2 1.5 2.9 0.6 4.6 1.5 2.9 0.6 4.9 1.5 311 16 321 165 -8.3 0 -8.1 -8.5 03/22/2007 06:30:00 3.3 0.4 4.2 2.3 3.2 0.7 4.2 1.1 3.3 0.5 4.2 2.3 327 17 323 165 -8.3 0.2 -8.1 -8.9 03/22/2007 06:40:00 4.1 0.7 5.3 2.3 3.2 1.1 5.7 0.7 4.3 0.7 5.3 2.3 354 8 340 165 -9 0 -8.9 -9.1 03/22/2007 06:50:00 3.3 0.8 4.6 1.5 3.5 0.9 4.9 1.5 3.6 0.8 4.9 1.9 336 11 342 165 -8.8 0.2 -8.5 -9.3 03/22/2007 07:00:00 2.4 0.6 3.8 1.1 2.5 0.6 3.8 0.7 2.6 0.4 3.8 1.5 327 19 323 165 -8.1 0.2 -7.6 -8.7 03/22/2007 07:10:00 4.1 0.7 5.7 2.6 4.1 0.7 5.7 2.6 3.9 0.6 5.3 1.9 316 10 332 165 -7.9 0 -7.6 -8.1 03/22/2007 07:20:00 2.2 0.7 3.4 0.7 2.4 0.6 3.4 0.4 2.4 0.5 3.8 1.1 328 16 294 165 -7.6 0.2 -7.2 -8.1 03/22/2007 07:30:00 1.5 0.6 2.6 0.4 1.7 0.5 2.6 0.7 2.1 0.5 3 0.7 334 23 358 165 -7.2 0.2 -6.8 -7.6 03/22/2007 07:40:00 1.8 1.2 3.8 0.4 2.2 1.1 3.8 0.4 2.3 0.8 4.2 1.1 308 9 292 165 -7.5 0 -7.4 -7.9 03/22/2007 07:50:00 1.6 0.8 3.4 0.4 1.8 0.8 3.8 0.4 2.1 0.7 4.2 0.7 314 9 301 165 -7.6 0.1 -7.4 -7.9 03/22/2007 08:00:00 2.2 0.5 3 0.4 2.2 0.5 3.4 0.4 2.6 0.5 3.4 1.5 320 15 321 165 -7.6 0 -7.4 -7.6 03/22/2007 08:10:00 1.9 0.7 3.8 0.7 1.7 0.9 3.8 0.4 2.3 0.6 3.8 1.5 349 22 339 165 -7.1 0.2 -6.6 -7.6 03/22/2007 08:20:00 3.6 0.6 5.3 2.6 3.6 0.6 5.7 2.3 3.7 0.7 5.3 2.6 333 15 338 165 -6.7 0.2 -6.4 -7.4 03/22/2007 08:30:00 3.2 0.4 4.6 2.3 3.3 0.4 4.6 2.3 3.3 0.4 4.2 2.3 326 13 336 165 -6.8 0.3 -6.4 -7.2 03/22/2007 08:40:00 3.5 0.4 4.9 2.3 3.6 0.5 5.3 1.9 3.7 0.4 5.3 2.6 335 7 338 165 -6.5 0.3 -5.9 -7.2 03/22/2007 08:50:00 3.8 0.4 4.9 2.6 3.5 0.7 4.9 1.9 4 0.4 4.9 2.6 343 8 332 165 -5.9 0.1 -5.7 -6.1 03/22/2007 09:00:00 3.4 0.4 4.6 2.6 3.3 0.6 4.9 1.9 3.5 0.4 4.9 2.6 345 7 344 165 -5.5 0.1 -5.3 -6.1 03/22/2007 09:10:00 4.1 0.6 5.3 2.6 4.1 0.7 5.7 2.3 4.1 0.7 6.1 2.6 338 9 334 165 -5.3 0 -5 -5.5 03/22/2007 09:20:00 3.7 0.3 4.6 3 3.9 0.4 4.9 2.6 3.7 0.4 4.6 2.6 338 6 341 165 -5.4 0.3 -4.8 -5.7 03/22/2007 09:30:00 4.1 0.4 5.3 3.4 4.1 0.6 5.7 2.6 4.1 0.4 5.7 3.4 344 6 341 165 -4.9 0.1 -4.6 -5.3 03/22/2007 09:40:00 4.4 0.4 5.3 2.6 3.6 0.8 5.3 1.9 4.5 0.4 5.7 3.4 352 5 354 165 -4.8 0.1 -4.6 -5.3 03/22/2007 09:50:00 4.7 0.6 6.1 3.4 3.3 0.9 6.1 1.5 4.9 0.6 6.5 3.4 355 6 348 165 -4.5 0.2 -4.2 -5 03/22/2007 10:00:00 4.5 0.5 6.1 3 2.9 0.7 5.3 1.9 4.8 0.5 6.1 3.4 358 6 345 165 -4.2 0.1 -3.9 -4.6 03/22/2007 10:10:00 4.1 0.7 6.1 2.3 3.1 0.7 5.3 1.9 4.2 0.7 6.1 2.6 355 9 357 165 -4 0.1 -3.7 -4.4 03/22/2007 10:20:00 3.4 0.4 4.6 2.6 2.9 0.8 4.9 1.1 3.6 0.4 4.6 2.6 353 9 342 165 -3.5 0.1 -3 -3.9 03/22/2007 10:30:00 3 0.6 4.6 1.5 2.7 0.8 4.6 1.1 3.1 0.5 4.2 2.3 352 10 350 165 -2.8 0.3 -2.4 -3.5 03/22/2007 10:40:00 2.5 0.6 3.8 0.7 2.1 0.6 3.8 0.4 2.6 0.7 4.2 0.7 8 19 357 165 -2.4 0.3 -1.7 -3 03/22/2007 10:50:00 3 0.4 4.2 1.9 2.5 0.6 3.8 1.1 3.1 0.4 4.2 1.9 13 12 12 165 -2.6 0.3 -1.9 -3.3 03/22/2007 11:00:00 3 0.5 3.8 1.9 2.8 0.7 4.2 1.1 3.1 0.5 3.8 1.9 25 12 26 165 -2.8 0.5 -2.1 -3.5 03/22/2007 11:10:00 3.8 0.5 5.3 2.6 3.3 0.8 4.9 1.5 4 0.5 5.3 2.6 15 7 27 165 -3.2 0.3 -2.6 -3.7 03/22/2007 11:20:00 4.3 0.3 5.3 3 4.1 0.5 5.3 2.6 4.4 0.4 5.3 3.4 21 7 31 165 -3.4 0.4 -2.6 -4.4 03/22/2007 11:30:00 4.4 0.4 5.3 2.6 4.3 0.6 5.3 1.5 4.6 0.5 5.7 3 23 7 29 165 -3.1 0.2 -2.6 -3.7 03/22/2007 11:40:00 4.9 0.6 6.1 3.8 5 0.6 6.5 3.4 5.2 0.7 6.8 3.4 26 5 31 165 -3.8 0.4 -3 -4.6 03/22/2007 11:50:00 4.4 0.6 5.7 2.6 4.4 0.7 5.7 1.9 4.6 0.5 6.1 3.4 23 6 28 165 -3.2 0.4 -2.4 -3.9 03/22/2007 12:00:00 4 0.5 5.3 2.3 3.3 0.8 5.3 1.5 4.2 0.5 5.3 3 13 10 18 165 -2.2 0.3 -1.7 -2.8 03/22/2007 12:10:00 4.8 0.7 6.8 3.4 4 1.2 6.8 1.5 4.9 0.6 7.2 3.4 10 12 32 165 -2.1 0.4 -1.7 -3.5 03/22/2007 12:20:00 4.3 0.8 6.5 2.6 3.5 1.1 6.5 1.1 4.5 0.9 7.2 2.3 4 12 4 165 -3.1 0.3 -2.6 -3.9 03/22/2007 12:30:00 4.8 0.7 6.5 3 3.7 1 6.5 1.5 5.1 0.8 6.8 3.4 7 12 27 165 -2.6 0.2 -2.1 -3 03/22/2007 12:40:00 5.4 0.6 7.2 3.8 3.7 0.8 6.1 1.9 5.7 0.6 7.6 3.8 4 8 6 165 -3 0.2 -2.6 -3.7 03/22/2007 12:50:00 5.2 0.8 7.2 3.8 3.9 1 7.2 1.9 5.4 0.8 7.2 4.2 3 9 348 165 -2.8 0.4 -2.1 -3.5 03/22/2007 13:00:00 5.2 0.6 6.8 3.4 3.6 0.9 6.1 1.9 5.4 0.6 6.8 3.8 359 8 353 165 -2.6 0.3 -2.1 -3.5 03/22/2007 13:10:00 5.3 0.6 7.2 3.8 3.9 1 6.5 2.3 5.6 0.6 7.6 3.4 7 8 12 165 -2.8 0.2 -2.4 -3.5 03/22/2007 13:20:00 4.8 0.6 6.5 3.4 3.6 0.8 6.1 1.9 5.1 0.7 6.5 3.4 2 9 11 165 -2 0.3 -1.4 -2.8 03/22/2007 13:30:00 4.9 0.7 6.8 2.3 3.8 1 6.5 1.5 5 0.7 6.8 2.6 356 11 7 165 -2.1 0.1 -1.7 -2.8 03/22/2007 13:40:00 4.4 1 6.5 2.6 3.5 0.8 5.7 1.9 4.5 1 7.2 2.6 10 11 357 165 -2.9 0.2 -2.4 -3.5 03/22/2007 13:50:00 4.6 0.7 6.5 2.6 4 0.9 6.1 1.9 4.7 0.6 6.5 3 12 11 16 165 -2.8 0 -2.6 -3.3 03/22/2007 14:00:00 5.2 1.4 8.8 2.3 5.1 1.6 9.1 1.9 5.4 1.4 8.4 2.6 23 11 37 165 -2.8 0.2 -2.1 -3.3 03/22/2007 14:10:00 6.1 1 8.4 3.8 6.2 1.1 8.8 3 6.4 1 8.8 3.8 28 11 27 165 -2.3 0.2 -1.9 -3 03/22/2007 14:20:00 5.7 0.6 7.2 4.2 4.6 1 6.8 2.3 5.9 0.6 7.2 3.8 358 10 357 165 -2.5 0.1 -2.1 -3 03/22/2007 14:30:00 5.5 1 8.8 3.4 4.5 0.9 7.2 2.3 5.5 1.1 8.4 3 353 9 358 165 -2.7 0 -2.6 -2.8 03/22/2007 14:40:00 7 1.2 9.5 4.2 5.9 1.3 8.8 2.6 7.1 1.4 9.9 3.4 8 12 6 165 -3.3 0.3 -2.8 -3.5 03/22/2007 14:50:00 8 1 9.9 5.7 7.3 1.5 9.9 3.4 8.1 1.1 11.1 5.7 16 9 21 165 -3.6 0 -3.3 -3.9 03/22/2007 15:00:00 7.6 0.8 9.5 5.3 6.6 1.4 9.5 3 7.6 0.9 9.9 5.3 14 11 19 165 -3.6 0 -3.3 -3.7 03/22/2007 15:10:00 7.3 1 9.5 4.6 5.9 1.5 9.1 2.6 7.5 1.2 11.5 4.9 8 12 7 165 -3.4 0.1 -3.3 -3.5 03/22/2007 15:20:00 7.7 1.1 9.9 4.9 5.8 1.1 8.4 3.4 7.8 1.2 10.3 5.3 356 8 359 165 -3.3 0 -3 -3.5 03/22/2007 15:30:00 7.7 0.7 9.5 5.7 5.5 1.3 9.5 3 7.7 0.9 9.5 5.3 357 6 2 165 -3.1 0.1 -2.8 -3.5 03/22/2007 15:40:00 8 1 10.3 4.9 6.3 1.3 9.5 3.8 8.2 1.1 10.7 4.9 354 8 354 165 -2.5 0.1 -2.1 -3 03/22/2007 15:50:00 8.1 1.1 11.5 5.7 6.3 1.7 10.3 2.6 8.3 1.3 11.8 5.7 1 12 10 165 -2.3 0 -1.9 -2.6 03/22/2007 16:00:00 8.1 1.5 11.8 3 6.8 1.7 11.5 2.3 8.5 1.6 12.2 4.9 8 12 14 165 -2.9 0.5 -1.9 -3.5 03/22/2007 16:10:00 7.4 1 9.9 4.9 6.1 1.3 9.5 3.4 7.6 1 10.7 4.2 5 14 21 165 -3.2 0.2 -2.8 -3.5 03/22/2007 16:20:00 6.9 1.3 9.9 3.8 6.8 1.5 9.9 3 6.7 1.2 9.9 4.2 331 15 328 165 -2.5 0.3 -1.9 -3.3 03/22/2007 16:30:00 8 1.5 13 4.9 8.1 1.5 13 5.3 8.1 1.7 13.7 4.2 325 10 323 165 -3.4 0.2 -2.6 -3.5 03/22/2007 16:40:00 10.6 1.7 16.8 7.2 10.8 1.6 16.4 7.2 10.9 1.7 16.8 7.2 329 8 341 165 -3.6 0 -3.5 -3.9 03/22/2007 16:50:00 11.7 1.5 15.6 8.4 11.8 1.5 16.1 7.6 12 1.5 16.4 8.4 335 8 324 165 -3.8 0 -3.5 -3.9 03/22/2007 17:00:00 12.6 1.6 16.1 8.8 12.7 1.7 16.4 8.8 12.7 1.8 16.4 8.8 334 8 326 165 -4.1 0.1 -3.9 -4.4 03/22/2007 17:10:00 10.7 1.7 14.9 6.5 10.8 1.7 14.9 6.5 10.8 1.9 14.9 6.5 331 8 332 165 -3.8 0.2 -3.5 -4.2 03/22/2007 17:20:00 11.7 1.9 17.2 6.8 11.7 1.9 17.2 6.5 11.6 2 17.2 5.7 330 11 328 165 -3.6 0 -3.5 -3.9 03/22/2007 17:30:00 12.7 1.7 17.2 8 12.9 1.7 17.6 8.4 12.8 1.7 17.6 6.8 329 9 342 165 -3.8 0 -3.5 -3.9 03/22/2007 17:40:00 13.6 1.6 19.1 9.9 13.7 1.6 18.7 8 13.7 1.6 19.1 8.8 332 7 338 165 -3.8 0 -3.5 -4.2 03/22/2007 17:50:00 12.6 1.7 16.4 8.4 12.6 1.7 16.4 8 12.6 1.7 17.6 8 335 9 330 165 -4.3 0 -3.9 -4.4 03/22/2007 18:00:00 13.2 2.2 18.3 6.8 13.2 2.1 17.9 6.8 13 2.2 17.9 7.2 332 7 328 165 -4.6 0.1 -4.4 -4.6 03/22/2007 18:10:00 12.6 1.8 17.2 7.6 12.7 1.8 17.6 7.6 12.5 1.7 16.8 8 329 9 318 165 -4.7 0 -4.6 -4.8 03/22/2007 18:20:00 10.9 1.9 15.3 6.8 10.9 1.9 15.6 6.5 10.7 1.9 16.1 6.8 326 10 336 165 -4.8 0 -4.6 -5 03/22/2007 18:30:00 9.9 1.6 14.5 5.3 9.9 1.6 14.5 5.3 9.8 1.7 14.5 6.1 322 10 330 165 -4.8 0 -4.6 -5 03/22/2007 18:40:00 10.1 1.3 13.3 6.8 10.1 1.3 13.7 6.8 9.6 1.5 14.1 5.3 317 10 322 165 -4.9 0 -4.6 -5.3 03/22/2007 18:50:00 9.7 1.3 13 5.7 9.6 1.3 13.3 6.1 8.7 1.3 11.8 5.7 310 11 314 165 -4.9 0 -4.6 -5 03/22/2007 19:00:00 10.3 1.3 13 6.1 10.2 1.3 13 6.1 9.4 1.4 13 5.7 312 9 320 165 -4.9 0 -4.6 -5.3 03/22/2007 19:10:00 10.1 1.2 13.3 7.2 10.1 1.2 13.7 6.8 9.8 1.4 13 5.3 315 8 319 165 -4.8 0 -4.6 -5.3 03/22/2007 19:20:00 9.6 1.3 14.1 6.8 9.3 1.5 14.5 5.7 9.4 1.6 13.3 5.3 322 17 328 165 -4.8 0 -4.6 -5 03/22/2007 19:30:00 9.9 1 13 7.2 9.9 1 13 7.6 9.9 1.1 13.7 8 324 9 328 165 -4.7 0 -4.4 -4.8 03/22/2007 19:40:00 8.4 1.3 11.8 5.3 8.2 1.5 12.6 3.4 8.4 1.3 11.5 5.7 332 13 336 165 -4.5 0 -4.4 -4.8 03/22/2007 19:50:00 8.7 1.5 13 5.7 8.7 1.5 13.7 5.7 8.5 1.5 13 5.3 331 10 351 165 -4.5 0 -4.4 -4.8 03/22/2007 20:00:00 10.8 1.3 15.3 8 10.9 1.5 15.3 8 10.8 1.5 14.9 7.6 332 9 341 165 -4.7 0.1 -4.4 -4.6 03/22/2007 20:10:00 11.2 1.5 15.3 7.2 11.2 1.5 16.4 6.1 11.1 1.7 15.6 7.6 330 12 342 165 -4.7 0 -4.4 -4.6 03/22/2007 20:20:00 11.4 1.5 15.3 7.2 11.3 1.5 15.6 7.2 9.9 1.3 13.7 6.8 306 12 287 165 -4.7 0 -4.4 -5 03/22/2007 20:30:00 13 1.7 18.3 9.5 13 1.7 17.9 9.5 10.2 1.6 16.1 6.8 299 8 311 165 -4.8 0 -4.4 -5 03/22/2007 20:40:00 13.7 1.5 18.3 10.7 13.8 1.5 18.7 10.7 10.6 1.7 16.1 7.6 296 8 297 165 -5 0 -4.6 -5.3 03/22/2007 20:50:00 14.9 1.5 20.2 11.8 15 1.5 19.5 11.1 12.1 1.7 17.6 8.4 303 8 307 165 -5 0 -4.8 -5.3 03/22/2007 21:00:00 15.3 1.2 18.3 12.2 15.4 1.2 18.3 12.2 12.4 1.6 16.8 8.8 304 6 299 165 -5 0 -5 -5.3 03/22/2007 21:10:00 15.7 1.2 18.7 11.1 15.7 1.3 18.7 11.1 13.3 1.6 18.3 8.8 306 7 314 165 -5.2 0 -5 -5.3 03/22/2007 21:20:00 15.6 1.2 17.9 10.7 15.5 1.2 17.9 10.3 13.9 1.5 17.6 9.5 309 7 307 165 -5.1 0 -4.8 -5.3 03/22/2007 21:30:00 16.3 1.5 21.4 13 16.3 1.5 21.4 13 14.7 1.9 21.8 10.3 309 10 318 165 -4.8 0.1 -4.4 -5 03/22/2007 21:40:00 16.9 1.2 20.2 13.3 16.9 1.2 20.6 13.3 15.6 1.5 19.1 10.7 309 6 302 165 -4.7 0 -4.6 -4.8 03/22/2007 21:50:00 17.3 0.9 20.2 14.9 17.3 0.9 20.6 14.9 16 1.1 19.9 13 310 5 309 165 -4.8 0 -4.6 -5 03/22/2007 22:00:00 16.9 1.1 19.9 13.7 16.9 1.1 19.9 13.7 16.3 1.1 18.7 12.6 311 5 303 165 -4.8 0 -4.6 -5 03/22/2007 22:10:00 15.6 0.8 17.6 13 15.5 0.8 17.2 13 14.8 1 17.2 10.7 311 4 312 165 -4.8 0 -4.6 -4.8 03/22/2007 22:20:00 15.5 0.9 19.1 13 15.5 0.9 19.5 13 13.8 1.1 16.8 11.1 308 5 314 165 -4.8 0 -4.6 -5 03/22/2007 22:30:00 15.2 1 17.9 12.2 15.2 1 17.9 12.2 12.9 1.7 18.3 9.5 305 6 307 165 -4.8 0 -4.6 -5 03/22/2007 22:40:00 15.2 0.8 17.9 11.8 15.3 0.9 17.9 12.6 12.8 1.5 17.2 9.1 304 5 308 165 -4.9 0 -4.6 -5 03/22/2007 22:50:00 14.4 1 17.2 11.1 14.4 1.1 17.2 11.1 13.1 1.3 16.4 9.5 309 6 304 165 -4.8 0 -4.6 -5 03/22/2007 23:00:00 15.7 1.2 20.6 12.6 15.7 1.2 21 12.2 14.3 1.6 18.7 10.3 308 6 310 165 -4.9 0 -4.6 -5 03/22/2007 23:10:00 16 1 18.7 13 16 1 18.7 12.6 14.8 1.2 17.6 11.1 307 5 307 165 -5 0 -4.8 -5.3 03/22/2007 23:20:00 15.9 1.3 19.9 12.2 15.9 1.4 19.9 11.8 15.1 1.6 19.9 10.7 309 6 312 165 -4.9 0.1 -4.6 -5.3 03/22/2007 23:30:00 15.2 1.1 18.3 12.6 15.2 1.1 17.9 12.2 13.3 1.7 17.9 9.5 306 7 301 165 -4.8 0 -4.6 -5 03/22/2007 23:40:00 15.1 1.1 17.9 12.2 15 1.1 17.9 12.2 14.1 1.4 17.9 9.5 310 6 312 165 -4.8 0 -4.6 -5 03/22/2007 23:50:00 16.1 1.2 19.5 13 16.1 1.2 19.9 13 15.1 1.3 18.7 11.5 309 6 300 165 -4.9 0 -4.6 -5 03/23/2007 00:00:00 16.9 1.3 20.2 13.3 16.8 1.3 20.2 13.3 15.9 1.6 19.9 10.7 310 6 303 165 -5 0 -4.8 -5 03/23/2007 00:10:00 18.3 1.2 22.1 15.3 18.2 1.2 22.1 14.9 17.5 1.3 21.8 13.7 310 6 311 165 -4.9 0 -4.6 -5.3 03/23/2007 00:20:00 18.6 1.3 21.4 14.9 18.5 1.3 21.8 14.5 17.6 1.4 21.4 13.7 310 5 308 165 -4.9 0 -4.6 -5 03/23/2007 00:30:00 18.1 1 20.6 13.3 18 1 20.6 13.7 17.5 1.3 21 13.3 312 6 298 165 -4.9 0 -4.6 -5 03/23/2007 00:40:00 18.6 1.1 21.8 14.9 18.6 1.2 22.1 15.3 18.1 1.2 21.8 14.1 311 5 308 165 -4.9 0 -4.6 -5 03/23/2007 00:50:00 18.2 1.2 21 14.5 18.1 1.2 21 14.5 17.8 1.5 21 13.7 311 6 314 165 -5 0 -4.8 -5.3 03/23/2007 01:00:00 17.6 1.1 20.6 14.1 17.6 1.1 20.6 14.1 17.5 1.5 21.4 11.8 313 5 312 165 -5 0 -4.8 -5.3 03/23/2007 01:10:00 17.2 1.2 20.2 14.1 17.1 1.2 20.6 13.7 16.1 1.3 20.2 11.8 310 5 302 165 -5 0 -4.8 -5.3 03/23/2007 01:20:00 17 1 19.5 14.1 17 1.1 19.5 14.1 16.3 1.3 20.2 12.6 311 6 312 165 -4.9 0 -4.8 -5 03/23/2007 01:30:00 17 0.9 19.5 14.9 16.9 1 19.5 14.5 16.3 1.2 18.7 12.2 311 5 307 165 -4.9 0 -4.8 -5 03/23/2007 01:40:00 16.3 1.2 19.5 12.6 16.2 1.2 19.5 13.3 16.1 1.2 19.5 12.2 313 5 316 165 -4.9 0 -4.6 -5 03/23/2007 01:50:00 15.4 1.2 17.9 12.2 15.3 1.2 17.9 11.8 15.1 1.4 18.7 9.9 313 5 310 165 -5 0 -4.6 -5 03/23/2007 02:00:00 14.3 1.2 17.2 10.3 14.2 1.2 17.6 10.3 14 1.3 17.2 9.9 313 5 316 165 -5.1 0.1 -4.8 -5.3 03/23/2007 02:10:00 14.3 1.2 17.6 11.1 14.2 1.2 16.8 10.7 13.8 1.4 16.4 9.1 313 6 318 165 -5.3 0 -5 -5.5 03/23/2007 02:20:00 15.1 1.3 17.9 11.5 15 1.3 17.6 11.1 13.8 1.5 16.4 9.5 309 5 316 165 -5.3 0 -5 -5.5 03/23/2007 02:30:00 12.6 1.3 16.1 8.8 12.5 1.3 16.4 9.1 11.8 1.7 15.6 7.6 308 8 308 165 -5.4 0 -5 -5.5 03/23/2007 02:40:00 12.1 1.2 15.3 9.1 12.1 1.2 15.3 9.1 10.4 1.5 14.9 7.2 305 8 298 165 -5.4 0 -5.3 -5.7 03/23/2007 02:50:00 11.9 1.2 14.9 9.1 11.9 1.2 14.9 9.1 10.2 1.5 14.9 7.2 306 8 314 165 -5.6 0 -5.5 -5.7 03/23/2007 03:00:00 12.5 1.2 15.3 9.5 12.5 1.2 15.3 9.5 11.3 1.3 15.3 7.6 307 7 304 165 -5.5 0 -5.5 -5.7 03/23/2007 03:10:00 11.3 1.6 15.3 8 11.3 1.7 15.3 8 9.5 1.5 14.9 5.7 302 8 307 165 -5.6 0 -5.5 -5.7 03/23/2007 03:20:00 11.9 1.4 15.6 8 11.8 1.5 16.1 8 10.2 1.4 14.1 7.2 304 9 291 165 -5.8 0 -5.5 -5.9 03/23/2007 03:30:00 12.3 1.4 15.6 8.8 12.3 1.4 15.6 8.4 10.6 1.6 16.4 7.2 303 9 302 165 -5.8 0 -5.5 -5.9 03/23/2007 03:40:00 12.4 1.3 16.1 9.1 12.3 1.3 16.1 9.1 11.5 1.3 14.9 8.4 310 9 301 165 -5.6 0 -5.5 -5.7 03/23/2007 03:50:00 11.8 1.3 15.3 7.2 11.6 1.3 15.3 7.6 10.7 1.6 14.5 6.8 310 9 312 165 -5.7 0 -5.5 -5.7 03/23/2007 04:00:00 10 1.4 13 6.5 9.9 1.3 13 6.8 8.7 1.6 13.3 4.9 306 9 304 165 -5.8 0 -5.5 -5.7 03/23/2007 04:10:00 8 1.8 13.3 3 8 1.7 13.3 3.8 6.8 1.7 11.1 3 293 13 303 165 -5.9 0 -5.7 -6.1 03/23/2007 04:20:00 7.5 2 12.2 0.7 7.5 2 12.6 0.7 5.7 2 10.7 1.1 294 17 296 165 -6 0 -5.7 -6.4 03/23/2007 04:30:00 7.9 1.9 13.7 3 7.9 1.8 13.7 3 6.2 1.7 12.2 2.6 293 14 286 165 -6 0 -5.7 -6.1 03/23/2007 04:40:00 8.6 1.1 13 5.3 8.6 1.1 12.2 5.7 7.2 1.3 10.3 4.2 290 11 286 165 -6.1 0 -5.7 -6.4 03/23/2007 04:50:00 8.7 1.4 12.6 4.9 8.7 1.3 12.6 5.3 7 1.4 11.1 3.4 292 11 307 165 -6.1 0 -5.9 -6.4 03/23/2007 05:00:00 8.6 1.6 13.3 4.9 8.6 1.6 12.6 4.9 6.9 1.5 12.2 3 294 9 262 165 -6.4 0.1 -6.1 -6.6 03/23/2007 05:10:00 9.4 1.5 13.3 6.1 9.3 1.4 13 6.1 7.6 1.2 11.5 4.2 296 9 292 165 -6.5 0 -6.1 -6.8 03/23/2007 05:20:00 9.8 1.3 14.1 6.5 9.7 1.3 14.1 6.5 8 1.7 13.3 4.2 290 9 277 165 -6.6 0 -6.6 -6.8 03/23/2007 05:30:00 9.5 1.1 12.2 6.8 9.4 1.1 12.2 6.5 7.8 1.3 12.2 5.3 298 9 282 165 -6.6 0.1 -6.4 -6.8 03/23/2007 05:40:00 10.5 1.2 13.7 7.2 10.4 1.2 13.3 7.6 8.4 1.2 13 5.7 299 9 297 165 -6.8 0 -6.6 -6.8 03/23/2007 05:50:00 12.2 1 14.9 10.3 12.1 1 14.9 10.3 9.5 1.4 14.1 6.5 294 8 289 165 -6.8 0 -6.6 -7.2 03/23/2007 06:00:00 12.2 1.1 14.5 8.8 12.2 1.1 14.5 8.8 9.2 1 11.8 6.5 295 7 295 165 -6.8 0 -6.6 -7.2 03/23/2007 06:10:00 12.6 1 15.6 9.5 12.6 1.1 15.6 9.1 9.6 1.3 14.5 6.8 294 7 301 165 -6.7 0 -6.6 -6.8 03/23/2007 06:20:00 12.5 1.1 15.3 9.9 12.5 1.1 15.3 9.9 9.3 1.1 12.6 6.5 299 6 299 165 -6.7 0 -6.6 -7 03/23/2007 06:30:00 13.4 1.2 16.4 10.7 13.3 1.2 16.8 10.7 10.3 1.5 14.5 6.5 299 8 296 165 -6.7 0 -6.6 -7.2 03/23/2007 06:40:00 13.2 1.1 15.6 9.9 13.2 1.1 15.6 9.9 10.3 1.3 13.7 7.2 298 7 301 165 -6.5 0 -6.4 -6.8 03/23/2007 06:50:00 13.6 1.1 17.2 10.3 13.6 1.2 16.8 10.7 9.9 1.2 13.7 6.8 297 7 299 165 -6.4 0 -6.1 -6.8 03/23/2007 07:00:00 11.9 1.3 15.3 8 11.9 1.3 14.9 8 9.4 1.3 14.1 6.1 297 9 302 165 -6.4 0 -6.1 -6.6 03/23/2007 07:10:00 11.8 1.6 14.9 6.8 11.7 1.6 14.9 6.8 8.9 1.3 12.2 4.9 297 9 304 165 -6.1 0.1 -5.9 -6.6 03/23/2007 07:20:00 11.8 1.5 15.3 8.8 11.7 1.5 14.9 8.8 9 1.2 13 6.1 298 9 298 165 -5.8 0.1 -5.5 -6.1 03/23/2007 07:30:00 12.3 1.3 15.3 9.9 12.2 1.3 15.3 9.5 9.7 1.4 14.1 6.8 303 6 302 165 -5.8 0.1 -5.5 -5.9 03/23/2007 07:40:00 14.4 1.1 17.6 11.5 14.3 1.2 17.6 11.5 11.5 1.5 15.6 8 305 6 304 165 -5.7 0 -5.5 -5.9 03/23/2007 07:50:00 12.7 1.3 16.1 9.1 12.6 1.3 16.1 9.1 10.7 1.3 14.1 7.2 305 7 305 165 -5.6 0 -5.5 -5.9 03/23/2007 08:00:00 11.7 1.2 14.5 8 11.6 1.3 14.5 8 9.8 1.3 13.3 6.8 306 8 304 165 -5.6 0 -5.5 -5.9 03/23/2007 08:10:00 11.2 1.3 14.1 8 11.1 1.2 13.7 7.6 9.1 1.2 12.6 6.1 302 7 307 165 -5.6 0 -5.5 -5.9 03/23/2007 08:20:00 9.8 1.7 13.7 6.1 9.7 1.6 13.3 5.7 8.2 1.6 12.6 4.9 303 8 304 165 -5.4 0 -5 -5.7 03/23/2007 08:30:00 10.6 1.2 13 7.6 10.5 1.1 13 7.6 8.3 1 11.8 5.7 299 6 285 165 -5.3 0 -5 -5.5 03/23/2007 08:40:00 11.3 0.9 13.3 8.8 11.2 1 13.3 8.8 8.7 1 12.2 6.5 297 7 298 165 -5.4 0 -5.3 -5.5 03/23/2007 08:50:00 11.6 1.1 14.1 9.1 11.6 1.1 14.1 9.1 8.7 1.2 13 6.5 295 6 290 165 -5.3 0 -5.3 -5.7 03/23/2007 09:00:00 11.4 1 13.7 8 11.4 1 13.7 8.4 8.3 1 12.2 6.1 297 6 300 165 -5.4 0 -5.3 -5.7 03/23/2007 09:10:00 11.5 1 14.1 9.1 11.4 1 14.1 9.1 8.6 0.9 11.1 6.5 296 6 289 165 -5.2 0 -5 -5.5 03/23/2007 09:20:00 11.7 0.8 13.7 9.9 11.7 0.9 14.1 9.5 9.1 1.3 13.3 6.5 295 6 301 165 -5.2 0 -5 -5.5 03/23/2007 09:30:00 11.2 0.8 13 9.1 11.3 0.8 13 9.5 8.6 1.2 12.2 6.5 295 5 302 165 -5 0 -4.8 -5.5 03/23/2007 09:40:00 10.3 0.9 12.2 7.6 10.3 0.8 12.2 7.6 8.7 1.1 11.8 6.1 304 7 307 165 -4.9 0 -4.6 -5.3 03/23/2007 09:50:00 9.2 1 11.8 6.5 9.2 1 11.5 6.5 8.3 1 10.7 5.7 308 7 298 165 -4.7 0.1 -4.2 -5 03/23/2007 10:00:00 7.8 0.8 10.7 6.1 7.7 0.8 10.3 6.1 7.6 0.7 9.5 5.7 317 7 301 165 -4 0.2 -3.5 -4.4 03/23/2007 10:10:00 6.9 1.3 10.3 4.2 6.9 1.3 10.3 3.8 6.4 1.5 10.3 3 312 8 322 165 -3.9 0.2 -3.5 -4.4 03/23/2007 10:20:00 7 1.2 9.9 4.2 6.9 1.2 9.9 3.8 6.2 1.4 9.1 3.4 309 9 313 165 -3.9 0 -3.5 -4.2 03/23/2007 10:30:00 8.6 0.7 11.1 6.1 8.6 0.7 10.7 5.7 7.3 0.9 9.5 4.6 306 6 290 165 -4 0.1 -3.9 -4.4 03/23/2007 10:40:00 8.3 0.9 10.3 6.1 8.3 0.9 10.7 6.1 6.7 0.9 9.1 4.2 303 6 292 165 -4.1 0 -3.9 -4.4 03/23/2007 10:50:00 7.9 1 10.7 5.3 7.9 1 10.3 6.1 6.7 1 9.5 4.2 294 9 303 165 -4.2 0.1 -3.9 -4.6 03/23/2007 11:00:00 7.4 0.9 9.1 3.8 7.4 0.9 9.1 3.8 6.2 1 9.5 3 304 9 319 165 -3.8 0.2 -3.5 -4.6 03/23/2007 11:10:00 7.6 1 10.3 4.6 7.6 1 10.3 4.2 6.5 1.1 9.1 3.4 302 9 298 165 -3.9 0.1 -3.5 -4.4 03/23/2007 11:20:00 6.8 1.3 9.5 3.8 6.7 1.3 9.5 3.8 5.7 1.2 9.1 2.6 301 12 296 165 -3.6 0.2 -3 -4.2 03/23/2007 11:30:00 7.3 1.2 10.7 4.6 7.2 1.2 10.3 4.6 6.1 1.2 9.1 3.4 308 11 295 165 -2.9 0.3 -2.6 -3.5 03/23/2007 11:40:00 6.4 1.2 8.8 3.4 6.4 1.2 9.1 3 5.6 1.2 8.4 2.6 309 11 311 165 -2.8 0.2 -2.1 -3 03/23/2007 11:50:00 4.5 1.4 7.6 1.5 4.4 1.3 7.6 1.9 4 1.3 7.2 1.5 303 18 323 165 -3 0 -2.6 -3.3 03/23/2007 12:00:00 2.5 1.3 5.7 0.4 2.7 1.3 5.3 0.4 2.3 1.3 4.9 0.4 286 23 278 165 -2 0.3 -1.4 -2.8 03/23/2007 12:10:00 3.2 0.8 5.7 1.5 3.4 0.8 6.1 1.9 3.1 0.8 5.7 1.5 277 22 272 165 -2.5 0 -2.4 -2.8 03/23/2007 12:20:00 4 1.2 6.8 1.1 4.2 1.3 6.8 1.1 3.9 1.3 6.8 1.5 285 16 268 165 -2.6 0.3 -2.1 -3.5 03/23/2007 12:30:00 5.2 1.5 8 1.9 5.2 1.4 8.4 2.3 4.4 1.2 7.6 1.9 303 13 314 165 -2.9 0.2 -2.1 -3.3 03/23/2007 12:40:00 6.9 1 9.1 4.2 6.8 0.9 9.1 4.6 5.9 1 8.8 3.8 308 8 304 165 -3.2 0 -3 -3.5 03/23/2007 12:50:00 6.8 1 9.5 4.9 6.7 1 9.5 4.6 6.1 1.1 8.8 3 312 7 313 165 -2.9 0.1 -2.6 -3.5 03/23/2007 13:00:00 7.5 1 9.9 4.9 7.5 1 9.9 4.9 6.1 0.9 9.1 3.8 302 8 302 165 -3 0.2 -2.6 -3.5 03/23/2007 13:10:00 7.2 1.3 10.3 4.2 7.1 1.3 10.3 4.2 6 1.3 10.7 3.4 300 10 312 165 -3.4 0 -3 -3.5 03/23/2007 13:20:00 6.9 1.2 9.5 3.4 6.9 1.2 9.5 3.8 5.6 1 8.4 3 302 10 303 165 -3.3 0 -3 -3.5 03/23/2007 13:30:00 7.7 1 9.9 4.9 7.6 1 9.5 5.3 6.4 1 9.5 4.2 302 8 301 165 -3.4 0 -3 -3.5 03/23/2007 13:40:00 7 0.9 9.5 4.6 7 0.9 9.5 4.6 6.2 1.2 9.5 3 303 12 293 165 -3.1 0.1 -2.8 -3.5 03/23/2007 13:50:00 7.7 1 10.3 5.3 7.7 1 10.3 5.3 6.8 1.2 10.3 4.2 296 11 297 165 -3.3 0 -3 -3.5 03/23/2007 14:00:00 9.1 1 11.8 6.5 9.1 1.1 11.8 6.8 7.4 1.1 10.3 4.6 297 8 290 165 -3.4 0 -3.3 -3.5 03/23/2007 14:10:00 9.4 0.9 11.8 6.5 9.3 1 11.8 6.5 7.8 1.2 10.7 4.9 305 8 302 165 -3.3 0.1 -3 -3.7 03/23/2007 14:20:00 9.9 1 11.8 7.2 9.9 0.9 11.5 7.2 7.9 1.1 11.1 5.3 304 6 304 165 -3.5 0.1 -3.3 -3.9 03/23/2007 14:30:00 9.2 1.6 12.6 5.7 9.2 1.5 12.2 5.7 8.1 1.9 12.2 4.2 304 10 312 165 -3.3 0 -3 -3.5 03/23/2007 14:40:00 10.3 0.9 13 7.6 10.3 0.9 13 7.6 9.7 1.2 12.2 6.1 310 6 302 165 -3.4 0.1 -3 -3.9 03/23/2007 14:50:00 9.8 1.5 13 6.5 9.7 1.4 13.3 6.5 9.4 1.8 14.1 4.9 315 8 321 165 -3.2 0.2 -2.8 -3.7 03/23/2007 15:00:00 8 0.9 10.3 6.1 8 0.9 10.3 5.3 7.1 1.3 9.9 4.2 306 10 302 165 -3.2 0.1 -2.8 -3.5 03/23/2007 15:10:00 7.8 0.8 9.5 5.7 7.8 0.8 9.9 5.7 6.6 1 9.5 4.6 301 10 298 165 -3.4 0.1 -3 -3.7 03/23/2007 15:20:00 7.4 0.7 9.5 4.9 7.4 0.8 9.5 4.6 6.2 1.1 9.5 3.4 293 8 279 165 -3.5 0 -3.3 -3.7 03/23/2007 15:30:00 6.9 0.9 9.5 4.2 6.9 0.9 9.9 4.2 6.1 1.1 9.5 4.2 309 7 318 165 -3.2 0.2 -2.8 -3.7 03/23/2007 15:40:00 7.5 1 10.3 5.3 7.5 1.1 10.3 4.9 6.4 0.8 9.1 4.2 306 9 302 165 -3.2 0.1 -2.8 -3.5 03/23/2007 15:50:00 7.5 0.8 9.9 5.3 7.5 0.8 9.9 4.9 6.8 1 10.3 4.6 310 10 290 165 -3.3 0.2 -3 -3.5 03/23/2007 16:00:00 7.9 1.3 10.7 4.6 7.9 1.4 10.7 4.9 6.7 1.5 10.7 2.6 297 12 281 165 -3.3 0.2 -2.8 -3.7 03/23/2007 16:10:00 8.2 1 10.3 5.7 8.2 1.1 10.7 5.3 6.5 1.2 10.7 3.4 295 8 278 165 -3.5 0 -3.3 -3.7 03/23/2007 16:20:00 7.5 1.3 11.1 4.6 7.5 1.3 10.7 4.9 6.2 1.2 8.8 3 298 11 291 165 -3.3 0.1 -2.8 -3.5 03/23/2007 16:30:00 7.6 1.3 10.3 4.2 7.6 1.2 10.3 4.6 6.5 1.4 11.1 3 305 12 297 165 -2.9 0 -2.8 -3.3 03/23/2007 16:40:00 6.5 1.2 9.5 3.4 6.4 1.2 9.9 3.4 5.5 1.1 8.8 2.6 308 10 294 165 -2.8 0 -2.6 -3 03/23/2007 16:50:00 6.4 1.3 9.1 3.4 6.4 1.3 9.1 3 5.3 1.3 8.8 1.9 303 12 314 165 -3.1 0 -2.8 -3.5 03/23/2007 17:00:00 8 1.7 11.8 3 8 1.7 11.8 3 6.7 1.4 9.9 2.6 306 11 302 165 -3.2 0.3 -2.6 -3.9 03/23/2007 17:10:00 7.4 1.5 11.1 4.6 7.4 1.5 11.1 4.6 6.2 1.3 9.1 3.4 301 10 302 165 -3.7 0.2 -3.3 -4.4 03/23/2007 17:20:00 7.5 1.4 11.5 4.6 7.4 1.3 11.1 4.2 6.4 1.3 10.7 3.8 307 9 317 165 -3.7 0 -3.5 -4.2 03/23/2007 17:30:00 8.8 1.1 11.8 5.7 8.7 1.1 11.5 5.7 7.8 1.3 11.5 4.2 311 10 314 165 -4 0.2 -3.5 -4.6 03/23/2007 17:40:00 7.5 1.1 11.1 5.3 7.4 1.1 10.7 5.3 6.5 1 9.1 4.2 310 9 307 165 -3.9 0.1 -3.5 -4.6 03/23/2007 17:50:00 6.6 1.1 9.1 2.6 6.6 1.1 9.1 3.4 5.7 1.2 8.4 2.6 308 9 306 165 -4.2 0.1 -3.9 -4.6 03/23/2007 18:00:00 9.2 1.3 12.2 5.3 9.2 1.3 12.2 4.9 7.6 1.1 11.1 4.6 303 9 301 165 -4.6 0.1 -4.2 -4.8 03/23/2007 18:10:00 8.8 1.2 11.8 6.1 8.7 1.2 11.8 6.1 7.1 1 10.7 4.6 299 9 296 165 -4.8 0 -4.6 -5 03/23/2007 18:20:00 7.4 1.3 10.3 4.6 7.4 1.4 10.7 4.9 6.2 1 9.9 3.8 303 10 302 165 -5 0 -4.8 -5.3 03/23/2007 18:30:00 9.8 1.2 12.2 5.3 9.8 1.2 11.8 5.3 7.8 1.3 11.5 4.6 293 6 286 165 -5.2 0.1 -5 -5.5 03/23/2007 18:40:00 9.9 0.8 11.8 8 9.9 0.8 11.8 7.6 7.3 0.8 10.7 5.3 297 6 297 165 -5.5 0 -5.3 -5.7 03/23/2007 18:50:00 8.9 1.2 11.5 5.7 8.9 1.1 11.5 6.5 6.9 1 9.1 4.2 296 8 300 165 -5.8 0.1 -5.5 -5.9 03/23/2007 19:00:00 7.8 1 9.9 5.7 7.8 1 9.9 5.3 6.3 1 9.5 4.2 295 10 286 165 -5.9 0 -5.7 -6.1 03/23/2007 19:10:00 8.4 1.1 10.7 5.3 8.4 1.1 10.7 5.3 6.5 0.9 9.1 4.2 294 9 287 165 -6.2 0.1 -5.9 -6.6 03/23/2007 19:20:00 10.1 0.7 12.6 7.6 10.2 0.7 12.2 7.6 7.9 1.2 11.8 5.3 292 6 282 165 -6.4 0 -6.1 -6.6 03/23/2007 19:30:00 10.3 1.2 13 7.2 10.3 1.2 13.3 7.2 8.3 1.4 12.6 5.7 294 9 286 165 -6.5 0 -6.4 -6.6 03/23/2007 19:40:00 9.1 1.2 12.2 6.5 9 1.2 12.2 6.1 8.5 1.4 11.5 5.3 309 11 299 165 -6.7 0.1 -6.6 -6.8 03/23/2007 19:50:00 10.4 1.2 13.7 8 10.4 1.1 14.1 7.6 9.8 1.3 13 6.1 310 11 302 165 -6.9 0 -6.6 -7 03/23/2007 20:00:00 10.9 1.1 14.1 8.8 10.8 1.1 13.7 8.4 9.5 1.2 13 6.5 304 8 306 165 -7 0 -6.8 -7.2 03/23/2007 20:10:00 11.7 0.9 13.7 9.5 11.6 1 13.7 9.1 9.5 1.1 13 7.2 302 7 297 165 -7.2 0 -6.8 -7.4 03/23/2007 20:20:00 11 1 13 8.8 11 1 13.3 8.4 8.3 0.9 10.7 6.1 297 9 298 165 -7.4 0 -7.2 -7.4 03/23/2007 20:30:00 11.9 1 14.1 9.1 11.9 1 14.5 9.5 8.7 1 11.8 6.1 292 8 296 165 -7.3 0 -7 -7.4 03/23/2007 20:40:00 12.3 1 14.5 8.8 12.3 1.1 14.5 8.8 8.9 0.9 11.5 6.5 291 8 293 165 -7.3 0.1 -7.2 -7.6 03/23/2007 20:50:00 13 0.9 15.3 10.3 13.1 0.9 15.3 10.3 9.9 1.5 13.7 6.8 291 7 287 165 -7.3 0 -7 -7.4 03/23/2007 21:00:00 13.3 0.7 15.6 11.1 13.3 0.8 15.3 11.1 9.5 1 12.2 7.2 298 7 287 165 -7.4 0 -7.2 -7.6 03/23/2007 21:10:00 11.8 0.9 13.3 8.8 11.7 0.8 13.7 9.1 9.9 1.3 13.7 6.8 304 7 301 165 -7.4 0 -7.2 -7.6 03/23/2007 21:20:00 9.2 1.1 11.5 5.7 9.2 1.1 11.5 6.1 7.9 0.9 10.7 5.7 306 10 299 165 -7.5 0 -7.4 -7.6 03/23/2007 21:30:00 7.2 0.8 9.1 4.9 7.2 0.8 9.5 5.3 7.2 0.7 9.5 5.3 325 10 332 165 -8 0.1 -7.6 -8.1 03/23/2007 21:40:00 8.9 1.3 11.8 5.7 8.8 1.3 11.8 5.7 8.3 1.2 11.1 5.7 313 8 312 165 -7.8 0.1 -7.6 -8.1 03/23/2007 21:50:00 9 1 11.8 6.5 8.9 1 11.8 6.8 8.5 1 11.5 5.7 313 9 314 165 -7.8 0 -7.6 -7.9 03/23/2007 22:00:00 8.3 1.2 10.7 4.9 8.2 1.2 10.7 4.9 8.1 1 10.7 4.9 317 11 312 165 -7.8 0 -7.6 -8.1 03/23/2007 22:10:00 7.1 1.3 10.3 3.4 7 1.3 10.3 3.4 6.8 1 9.9 4.6 319 10 314 165 -8 0 -7.6 -8.1 03/23/2007 22:20:00 6.1 1.5 10.3 3 6.1 1.5 10.3 3 5.5 1.5 9.9 2.3 319 12 316 165 -8 0 -7.9 -8.3 03/23/2007 22:30:00 6.8 0.9 9.1 4.2 6.7 0.9 9.1 4.6 6.5 1 9.1 4.2 320 10 312 165 -8.1 0 -8.1 -8.3 03/23/2007 22:40:00 5.7 1.2 9.1 3.4 5.7 1.2 9.1 3.4 5.4 1.3 9.1 3 313 9 319 165 -8.1 0 -7.9 -8.3 03/23/2007 22:50:00 5.4 0.8 7.6 3.8 5.3 0.9 7.6 3.8 4.8 0.6 6.5 3 311 10 268 165 -8.5 0.1 -8.3 -8.7 03/23/2007 23:00:00 6.4 0.8 8.4 3.4 6.4 0.8 8.4 3.8 5.4 0.8 8 3.4 304 9 307 165 -8.5 0 -8.3 -8.7 03/23/2007 23:10:00 4.3 1.2 6.8 1.1 4.4 1.1 6.8 1.1 3.4 1 6.1 1.5 301 15 289 165 -8.6 0 -8.5 -8.9 03/23/2007 23:20:00 5.8 1.3 9.9 1.9 5.7 1.3 9.9 1.9 5.2 1.3 7.6 1.5 316 12 302 165 -8.4 0.2 -7.9 -8.9 03/23/2007 23:30:00 8.2 1.7 13.3 5.7 8.1 1.6 13 5.7 8 1.7 12.2 4.2 317 10 298 165 -7.8 0.1 -7.4 -8.1 03/23/2007 23:40:00 8.4 1.7 12.2 5.7 8.4 1.7 12.2 5.7 7.8 1.8 12.2 4.2 312 13 308 165 -7.6 0 -7.4 -7.9 03/23/2007 23:50:00 9.3 1.3 12.2 6.1 9.2 1.2 11.8 6.1 8.1 1.6 12.6 4.2 306 11 316 165 -7.7 0 -7.4 -7.9 03/24/2007 00:00:00 10 2 13.7 5.7 9.8 2.3 13.3 2.6 8.5 1.7 14.1 5.3 311 19 312 165 -7.6 0 -7.4 -7.9 03/24/2007 00:10:00 9.4 1.5 12.2 4.6 9.3 1.5 12.2 4.9 8.7 1.6 11.8 4.2 313 13 317 165 -7.9 0.2 -7.4 -8.1 03/24/2007 00:20:00 9.8 1.4 12.6 5.7 9.7 1.3 12.2 5.3 8.8 1.4 13 5.3 310 12 313 165 -8 0 -7.6 -8.1 03/24/2007 00:30:00 9.5 1.1 12.2 6.5 9.4 1 11.8 6.8 8.5 1.3 11.5 5.3 307 10 325 165 -8 0 -7.9 -8.3 03/24/2007 00:40:00 10.5 1.5 13.7 7.2 10.3 1.4 13.7 6.5 8.8 1.2 12.6 6.1 304 7 305 165 -8.1 0 -7.9 -8.3 03/24/2007 00:50:00 10.1 1.2 12.2 6.5 10 1.1 12.6 6.5 8.2 1.1 11.5 6.1 302 9 307 165 -8.1 0 -7.9 -8.3 03/24/2007 01:00:00 10.1 1 12.6 7.2 10.1 1 12.2 7.2 8.4 1.3 11.5 5.7 303 8 306 165 -8.1 0 -7.9 -8.5 03/24/2007 01:10:00 10 1 12.6 7.2 9.9 1 12.6 6.8 9.1 1.1 12.2 5.3 309 8 313 165 -8 0 -7.6 -8.1 03/24/2007 01:20:00 8.5 1.1 11.1 4.6 8.4 1.1 11.1 4.9 7.6 1.1 11.1 3.8 308 11 301 165 -8 0 -7.6 -8.3 03/24/2007 01:30:00 8.4 1.7 12.2 4.6 8.3 1.7 11.8 4.6 7.7 1.5 11.5 4.6 314 12 310 165 -8 0 -7.6 -8.1 03/24/2007 01:40:00 6.3 1.1 9.5 4.2 6.3 1 9.5 3.4 5.7 1.1 9.1 3 311 11 291 165 -8.1 0 -7.9 -8.5 03/24/2007 01:50:00 6.6 1 9.1 4.6 6.6 1 9.1 4.6 5.9 1 8.4 3.8 308 9 295 165 -8.4 0.1 -8.3 -8.7 03/24/2007 02:00:00 6.2 1.1 8.8 3.8 6.2 1.1 8.8 3.8 5.1 1.2 9.1 2.6 301 9 317 165 -8.5 0 -8.3 -8.7 03/24/2007 02:10:00 5.8 1 9.5 3.8 5.8 1 9.9 3.8 4.6 1 7.6 3 298 9 290 165 -8.7 0 -8.5 -8.9 03/24/2007 02:20:00 6.7 1 9.5 4.6 6.7 1 9.1 4.6 5.4 1 8.8 3 300 10 310 165 -8.6 0 -8.5 -8.9 03/24/2007 02:30:00 5.5 1.1 8 3 5.4 1.1 8 3 4.7 0.9 7.2 2.6 307 11 312 165 -8.7 0 -8.5 -9.1 03/24/2007 02:40:00 5 0.7 6.5 3.4 5 0.8 6.8 3 4.2 0.7 6.8 2.6 304 11 310 165 -9.1 0 -8.9 -9.1 03/24/2007 02:50:00 4.5 0.9 7.2 1.9 4.5 0.9 7.2 2.3 3.8 0.9 6.5 1.9 306 11 303 165 -8.7 0.2 -8.5 -9.1 03/24/2007 03:00:00 5.5 0.9 8 2.6 5.4 0.9 7.6 3 4.9 1 6.8 2.6 308 9 305 165 -8.5 0.1 -8.3 -8.7 03/24/2007 03:10:00 6.7 0.8 8.8 4.9 6.7 0.8 8.4 4.9 5.6 1 7.6 3.4 304 7 302 165 -8.6 0.1 -8.5 -8.7 03/24/2007 03:20:00 7.2 1.1 11.5 4.6 7.1 1.1 11.5 4.9 5.9 1 9.1 3.4 304 13 310 165 -8.5 0 -8.3 -8.7 03/24/2007 03:30:00 6.9 0.8 8.8 5.3 6.9 0.7 8.8 5.3 6 0.9 8.4 3.8 307 10 307 165 -8.4 0.1 -8.1 -8.5 03/24/2007 03:40:00 7.4 0.8 10.3 5.3 7.3 0.8 10.3 5.3 6 0.9 8.8 3.8 301 10 283 165 -8.4 0.1 -8.3 -8.5 03/24/2007 03:50:00 4.5 1.2 7.6 2.6 4.5 1.2 8 2.3 4.3 1 7.2 2.3 317 16 290 165 -8.3 0.2 -8.1 -8.5 03/24/2007 04:00:00 7.2 1.4 10.7 4.6 7.2 1.3 10.3 4.2 5.8 1.5 9.9 3.4 302 12 306 165 -8.4 0.1 -8.1 -8.7 03/24/2007 04:10:00 7.2 0.7 9.1 5.3 7.2 0.7 8.8 4.9 6.1 1 8.4 3.8 300 11 306 165 -8.5 0.2 -8.1 -8.9 03/24/2007 04:20:00 7.4 0.6 9.1 5.7 7.4 0.6 9.1 6.1 6 0.8 8 4.2 306 5 310 165 -8.9 0 -8.7 -8.9 03/24/2007 04:30:00 7.7 0.7 9.5 5.7 7.7 0.7 9.5 5.7 6.1 1.1 9.5 3.8 294 8 297 165 -8.8 0 -8.5 -9.1 03/24/2007 04:40:00 8 0.6 9.5 6.1 8 0.6 9.5 6.1 6.7 1 9.5 4.6 293 7 289 165 -8.8 0 -8.5 -9.1 03/24/2007 04:50:00 7.5 1 10.7 5.3 7.6 1 10.7 5.3 6 1 9.1 3.8 296 8 304 165 -8.9 0 -8.7 -9.1 03/24/2007 05:00:00 7.2 0.8 9.5 5.3 7.3 0.8 9.5 5.3 6.3 1 9.5 4.2 292 7 282 165 -8.7 0 -8.5 -9.1 03/24/2007 05:10:00 8.8 1.2 11.8 6.1 8.8 1.2 11.8 6.1 7.6 1.3 10.7 4.2 296 12 284 165 -8.8 0 -8.5 -9.1 03/24/2007 05:20:00 6.9 0.6 9.1 4.9 6.9 0.7 9.1 4.9 5.6 1 9.1 3.8 302 7 308 165 -8.7 0 -8.5 -9.1 03/24/2007 05:30:00 5.4 0.8 8 3.8 5.4 0.8 7.6 4.2 4.7 1 7.2 3 306 9 303 165 -8.9 0.2 -8.5 -9.3 03/24/2007 05:40:00 4.4 0.6 5.7 2.6 4.3 0.6 5.7 2.6 4 0.5 5.3 1.9 307 9 293 165 -9.3 0.1 -9.1 -9.3 03/24/2007 05:50:00 6.9 0.9 8 4.2 7 1 8.4 4.2 5.3 0.7 6.8 2.6 300 6 305 165 -9 0 -8.9 -9.3 03/24/2007 06:00:00 7.1 0.5 8.4 5.7 7.1 0.5 8.4 6.1 5.4 0.5 6.8 4.2 303 4 298 165 -8.9 0.1 -8.7 -9.1 03/24/2007 06:10:00 8 0.7 9.5 6.5 8.1 0.7 9.9 6.5 5.8 0.8 8.4 4.2 300 5 303 165 -9.1 0 -8.9 -9.1 03/24/2007 06:20:00 8.2 0.5 9.5 6.8 8.3 0.5 9.5 6.8 6 0.7 9.1 4.6 302 5 312 165 -9.1 0 -8.9 -9.3 03/24/2007 06:30:00 8.6 0.8 11.1 6.5 8.6 0.8 10.7 6.1 7.2 1 9.9 5.3 307 5 308 165 -9.1 0 -8.9 -9.3 03/24/2007 06:40:00 8.5 0.5 10.7 7.2 8.5 0.5 10.3 7.2 6.9 0.9 9.1 4.9 307 4 301 165 -9 0 -8.7 -9.1 03/24/2007 06:50:00 8.4 0.6 10.3 7.2 8.5 0.6 10.7 7.2 6.4 0.8 8.4 4.6 304 4 304 165 -9 0 -8.9 -9.3 03/24/2007 07:00:00 8.6 0.7 11.1 6.8 8.7 0.8 11.1 6.5 6.8 0.7 9.1 5.3 305 4 298 165 -8.8 0 -8.5 -9.3 03/24/2007 07:10:00 8.7 0.8 11.1 7.2 8.7 0.8 11.1 7.2 6.5 1 9.5 4.6 300 7 290 165 -8.7 0 -8.5 -9.1 03/24/2007 07:20:00 8.7 1 11.1 6.5 8.7 1 11.5 6.5 6.6 0.9 9.1 4.2 301 7 302 165 -8.4 0 -8.1 -8.7 03/24/2007 07:30:00 8.7 0.8 10.7 6.1 8.7 0.8 10.3 6.1 6.8 0.9 9.1 4.9 302 7 308 165 -8.2 0 -8.1 -8.5 03/24/2007 07:40:00 8.3 0.8 10.3 6.1 8.3 0.8 10.7 6.1 6.5 0.8 9.1 4.2 300 9 296 165 -8.1 0 -7.9 -8.3 03/24/2007 07:50:00 8.4 1 11.5 6.1 8.4 1 11.1 6.1 6.6 0.9 9.9 4.6 301 8 268 165 -8 0 -7.9 -8.1 03/24/2007 08:00:00 8.1 0.9 9.9 5.7 8.1 1 10.3 5.7 6.7 0.9 9.1 4.6 301 10 278 165 -7.9 0 -7.6 -8.1 03/24/2007 08:10:00 7.6 1.5 11.5 4.6 7.6 1.5 11.1 4.6 6.5 1.1 9.9 4.2 302 9 294 165 -7.7 0 -7.4 -8.1 03/24/2007 08:20:00 8.3 1.1 11.1 5.7 8.3 1.1 11.1 5.7 7.1 1 10.3 4.6 305 10 299 165 -7.6 0 -7.2 -8.1 03/24/2007 08:30:00 8.6 1 11.8 6.5 8.6 1 11.8 6.1 7.1 0.8 9.5 4.9 304 8 299 165 -7.6 0 -7.4 -8.1 03/24/2007 08:40:00 9 0.8 11.1 6.5 9 0.9 11.1 6.5 7.5 1 10.3 4.9 303 8 292 165 -7.8 0 -7.6 -8.1 03/24/2007 08:50:00 7.4 1.5 10.7 3.8 7.4 1.5 10.7 3.8 6.3 1 9.1 3.8 305 10 293 165 -7.5 0 -7.2 -8.1 03/24/2007 09:00:00 7.8 1.3 10.7 4.6 7.8 1.3 10.7 4.6 6.5 1.4 10.7 3.8 298 9 289 165 -7.3 0.2 -6.8 -7.6 03/24/2007 09:10:00 7.1 1.3 10.3 3.4 7.1 1.3 10.3 3.4 5.7 1.1 9.1 3.4 299 9 293 165 -7.3 0.1 -6.8 -7.6 03/24/2007 09:20:00 6.8 1.2 9.9 3.8 6.8 1.2 9.9 3.8 5.5 1 9.1 3.4 299 9 292 165 -7.3 0 -7 -7.6 03/24/2007 09:30:00 8 1 10.7 5.7 8.1 1 10.7 5.7 6.3 0.9 8.8 4.2 294 7 294 165 -7.5 0 -7.2 -7.6 03/24/2007 09:40:00 8.8 0.8 10.7 6.8 8.8 0.8 10.7 6.8 6.7 0.9 9.5 4.9 294 6 282 165 -7.5 0.1 -7.2 -7.9 03/24/2007 09:50:00 7.8 0.9 10.3 5.7 7.8 0.9 10.3 5.7 6.5 1 9.1 3.4 305 8 293 165 -7.2 0 -6.8 -7.6 03/24/2007 10:00:00 8.6 0.8 10.3 6.1 8.6 0.8 10.7 6.5 7 1.2 9.5 4.6 295 6 292 165 -7.3 0 -7.2 -7.4 03/24/2007 10:10:00 8.2 1 9.9 5.3 8.2 1 9.9 5.3 6.2 0.7 8.4 4.6 302 5 298 165 -7.2 0.1 -6.8 -7.6 03/24/2007 10:20:00 8.5 0.6 10.3 6.8 8.5 0.6 10.3 6.8 7 0.8 9.1 5.3 305 5 305 165 -7.1 0.1 -6.8 -7.4 03/24/2007 10:30:00 8.6 0.8 10.3 6.1 8.6 0.8 10.3 6.5 7.4 0.9 9.1 5.7 306 6 302 165 -6.9 0 -6.8 -7.2 03/24/2007 10:40:00 8.4 0.6 9.5 6.5 8.5 0.6 9.5 6.8 6.6 0.9 9.1 4.2 299 6 302 165 -6.9 0.1 -6.6 -7 03/24/2007 10:50:00 6.7 0.7 8.4 4.9 6.7 0.7 8.4 4.9 6.1 1 8.8 3.8 298 11 300 165 -6.8 0 -6.6 -7.2 03/24/2007 11:00:00 5.6 0.7 7.6 3.8 5.6 0.7 7.6 3.4 5.3 0.9 7.6 3 309 8 313 165 -6.2 0.1 -5.9 -6.8 03/24/2007 11:10:00 6.6 0.7 8.8 4.6 6.7 0.8 8.8 4.6 5.3 0.9 8.4 3.4 297 6 310 165 -6.5 0.1 -6.1 -7 03/24/2007 11:20:00 6.7 0.9 8.8 4.2 6.7 0.9 8.8 4.2 5.1 0.9 7.2 2.6 295 5 302 165 -6.6 0.1 -6.4 -7 03/24/2007 11:30:00 6.8 1 9.1 4.2 6.8 1 9.1 4.2 5.4 0.9 7.6 3.4 302 7 304 165 -6.4 0.1 -6.1 -6.6 03/24/2007 11:40:00 6.7 0.6 8 4.9 6.6 0.6 8 4.9 5.8 0.9 8.4 4.2 307 7 307 165 -5.9 0.2 -5.5 -6.6 03/24/2007 11:50:00 7.2 0.6 8.8 5.3 7.2 0.6 8.4 5.3 5.7 0.6 7.6 4.2 303 5 302 165 -6 0 -5.7 -6.6 03/24/2007 12:00:00 7 0.7 8.4 4.9 7 0.7 8.4 5.3 5.7 0.7 7.6 3.8 303 5 305 165 -6 0 -5.7 -6.4 03/24/2007 12:10:00 6.3 0.5 7.2 4.9 6.3 0.5 7.6 4.9 4.9 0.5 6.5 3.8 302 5 301 165 -5.8 0 -5.5 -6.1 03/24/2007 12:20:00 6 0.4 7.2 4.9 6 0.4 7.2 4.9 5.1 0.6 6.8 3.8 306 5 311 165 -5.4 0.1 -5.3 -5.7 03/24/2007 12:30:00 5.4 0.7 7.2 3.4 5.3 0.7 6.8 3 4.9 0.8 6.8 2.6 308 8 295 165 -5 0.1 -4.6 -5.5 03/24/2007 12:40:00 5.7 0.6 7.6 4.2 5.6 0.6 7.2 4.2 5.1 0.8 7.2 3 310 10 300 165 -4.8 0.1 -4.4 -5 03/24/2007 12:50:00 6 0.5 7.6 4.6 6 0.5 7.6 4.6 4.9 0.7 6.8 3.4 305 6 299 165 -4.8 0.2 -4.2 -5.3 03/24/2007 13:00:00 6.3 0.6 7.6 4.6 6.3 0.6 7.6 4.6 5.1 0.6 6.5 3.4 304 5 305 165 -5.2 0 -5 -5.3 03/24/2007 13:10:00 6.4 0.7 7.6 3.4 6.4 0.7 7.6 3.8 5.5 0.6 6.8 3.4 306 4 304 165 -5.2 0 -4.8 -5.3 03/24/2007 13:20:00 5.7 0.6 6.8 4.2 5.7 0.6 6.8 4.2 5.1 0.9 7.2 2.6 308 9 303 165 -4.8 0.1 -4.6 -5 03/24/2007 13:30:00 6.5 0.5 8 4.6 6.5 0.6 8 4.6 5.6 0.6 7.2 3.8 307 5 301 165 -4.8 0 -4.4 -5 03/24/2007 13:40:00 5.3 0.9 7.2 2.6 5.3 0.9 7.2 2.6 4.5 0.9 6.8 2.3 307 9 314 165 -4.5 0.2 -4.2 -5 03/24/2007 13:50:00 4.1 0.6 5.7 2.3 4.1 0.6 5.3 2.3 3.6 0.6 5.3 1.9 303 16 313 165 -4.2 0.2 -3.5 -4.6 03/24/2007 14:00:00 5.7 0.9 7.6 3 5.6 0.9 7.2 2.6 5.4 1.1 7.6 2.3 313 7 322 165 -4 0.2 -3.3 -4.4 03/24/2007 14:10:00 6.5 0.8 8.4 4.2 6.4 0.8 8 4.2 6.3 0.9 8.4 3.8 313 6 315 165 -4.2 0.1 -3.9 -4.4 03/24/2007 14:20:00 5.8 0.6 7.2 3.8 5.7 0.6 7.2 3.8 5.6 0.7 7.6 3.8 315 7 313 165 -4 0.1 -3.7 -4.4 03/24/2007 14:30:00 5.6 0.9 7.6 3 5.6 0.8 7.6 3 5.6 0.8 7.2 3.8 317 8 319 165 -3.8 0.1 -3.5 -4.4 03/24/2007 14:40:00 6 0.6 7.6 4.2 6 0.6 7.2 3.8 5.6 0.8 7.2 3 312 7 320 165 -4 0.3 -3.5 -4.6 03/24/2007 14:50:00 6.7 0.5 8 5.3 6.6 0.5 8 5.3 6.4 0.6 7.6 4.6 312 5 315 165 -4.4 0 -4.2 -4.8 03/24/2007 15:00:00 5.9 0.6 7.2 3.8 5.9 0.7 7.6 3.4 5.1 0.8 6.8 2.6 305 9 300 165 -4.5 0.1 -4.2 -5 03/24/2007 15:10:00 5.6 0.7 7.2 4.2 5.6 0.7 7.2 3.8 4.7 0.6 6.1 3 302 9 302 165 -4.7 0.1 -4.4 -5.3 03/24/2007 15:20:00 5.8 1.1 8.4 3.4 5.8 1.1 8.4 3.4 5 1 7.6 2.3 307 11 309 165 -4.5 0 -4.2 -4.6 03/24/2007 15:30:00 6.3 0.8 8 4.2 6.3 0.8 8 4.6 5.5 1 8 3.4 301 11 316 165 -4.5 0 -4.4 -4.8 03/24/2007 15:40:00 6.1 0.7 8 4.6 6.1 0.7 8 4.2 4.9 0.7 7.2 3.4 298 7 295 165 -4.8 0.1 -4.6 -5.5 03/24/2007 15:50:00 5.2 0.8 6.8 3.4 5.2 0.8 6.8 3.4 4.3 0.8 6.5 2.6 299 9 302 165 -4.7 0.1 -4.4 -5 03/24/2007 16:00:00 5 0.8 6.8 2.6 5 0.8 6.8 2.6 4.3 0.7 6.1 2.6 304 9 291 165 -4.3 0.1 -3.9 -4.6 03/24/2007 16:10:00 5.8 0.7 7.2 3.8 5.8 0.7 7.2 3.8 4.8 0.7 6.5 3 302 10 304 165 -4.6 0 -4.4 -5 03/24/2007 16:20:00 5.8 0.7 7.6 3.8 5.8 0.7 7.2 3.8 5 0.9 7.2 3 302 9 310 165 -4.5 0.3 -3.9 -5 03/24/2007 16:30:00 6.6 0.7 8.4 4.6 6.6 0.8 8.4 4.2 5.4 0.8 7.6 3 301 9 293 165 -4.8 0.2 -4.4 -5.3 03/24/2007 16:40:00 6.1 0.8 8 4.2 6.1 0.8 8 4.2 4.7 0.8 7.2 3 298 6 298 165 -4.9 0.1 -4.6 -5.5 03/24/2007 16:50:00 6 0.7 7.6 4.6 6 0.6 7.6 4.2 5.4 0.8 7.6 3.4 306 8 303 165 -4.8 0 -4.6 -5.3 03/24/2007 17:00:00 6.8 0.9 8.8 4.6 6.8 0.9 8.8 4.2 5.9 0.9 8.4 3.8 305 10 303 165 -5.1 0.1 -4.6 -5.7 03/24/2007 17:10:00 6.9 1 9.9 4.2 6.9 1 9.5 4.2 5.8 0.9 8 3.4 304 9 291 165 -5.2 0.1 -4.8 -5.7 03/24/2007 17:20:00 6.8 0.9 9.1 4.9 6.8 0.9 9.1 4.9 5.6 0.8 7.6 3.8 304 7 290 165 -5.2 0 -5 -5.7 03/24/2007 17:30:00 6.4 0.9 8.4 4.2 6.5 0.9 8.4 4.2 5.1 0.9 7.6 3.4 295 8 293 165 -5.4 0 -5 -5.9 03/24/2007 17:40:00 6.9 0.8 8.4 4.9 6.9 0.8 8.8 4.9 5.4 0.8 7.6 3.4 297 7 290 165 -5.5 0 -5.5 -5.7 03/24/2007 17:50:00 6.8 0.6 8.8 5.3 6.9 0.6 8.8 5.3 5.5 0.8 8 3.4 293 7 291 165 -5.7 0 -5.5 -5.7 03/24/2007 18:00:00 8.2 0.7 9.5 5.7 8.2 0.7 9.9 5.7 6.7 1 9.5 4.2 290 5 291 165 -5.9 0 -5.7 -6.1 03/24/2007 18:10:00 7.9 0.6 9.1 6.1 8 0.6 9.5 6.5 6.4 1 9.5 4.6 292 6 286 165 -5.9 0 -5.7 -6.1 03/24/2007 18:20:00 7.6 0.6 9.1 5.7 7.7 0.6 9.1 6.1 5.9 0.8 8 3.8 292 5 276 165 -6 0 -5.9 -6.4 03/24/2007 18:30:00 7.8 1 9.9 5.3 7.8 1 9.9 5.3 5.8 0.8 7.6 3.4 295 8 295 165 -6.1 0 -6.1 -6.4 03/24/2007 18:40:00 8.8 0.8 9.9 6.8 8.8 0.9 10.3 6.5 6.5 0.6 8.4 4.6 298 8 294 165 -6.4 0 -6.1 -6.6 03/24/2007 18:50:00 7.2 0.7 8.8 5.3 7.2 0.7 8.8 5.3 6 1 8.4 3.8 300 10 306 165 -6.6 0 -6.4 -6.8 03/24/2007 19:00:00 7.9 0.6 9.5 6.1 7.9 0.6 9.1 6.5 6.3 0.9 8.8 4.6 291 7 295 165 -6.7 0 -6.6 -6.8 03/24/2007 19:10:00 6.4 0.7 8 4.6 6.5 0.7 8.4 4.6 6.2 1 8.4 3.8 282 5 281 165 -6.9 0.1 -6.6 -7.2 03/24/2007 19:20:00 6.2 0.9 8.4 3.8 6.3 0.9 8.4 3.8 5.7 1 8.4 3 283 8 288 165 -7.2 0 -6.8 -7.4 03/24/2007 19:30:00 8.3 1.2 11.1 5.3 8.3 1.2 11.1 5.7 6.8 1.1 10.7 4.2 289 9 291 165 -7.4 0 -7.2 -7.6 03/24/2007 19:40:00 8.9 1.1 11.8 5.7 8.8 1.1 11.8 6.1 6.8 1 9.5 4.6 294 10 295 165 -7.4 0.1 -7.2 -7.6 03/24/2007 19:50:00 9.7 0.7 11.1 7.2 9.6 0.8 11.1 7.2 7.4 0.9 9.5 5.3 297 10 280 165 -7.4 0 -7.2 -7.6 03/24/2007 20:00:00 8.2 0.7 9.5 6.1 8.2 0.7 9.5 6.1 6.6 0.9 9.1 4.2 298 9 298 165 -7.4 0.1 -7.2 -7.6 03/24/2007 20:10:00 9.8 0.6 11.5 6.8 9.8 0.6 11.5 7.2 6.8 0.7 9.9 5.3 293 7 295 165 -7.8 0 -7.4 -7.9 03/24/2007 20:20:00 9.3 0.7 10.7 6.8 9.4 0.7 11.1 6.5 6.9 1.1 10.3 4.6 291 8 290 165 -7.6 0.1 -7.4 -8.1 03/24/2007 20:30:00 8.5 0.6 9.9 6.8 8.6 0.6 9.9 6.8 7 1 9.1 4.9 289 6 287 165 -7.7 0 -7.4 -8.1 03/24/2007 20:40:00 9.1 0.5 10.3 7.6 9.2 0.5 10.7 8 8.4 1 10.3 5.7 286 4 284 165 -7.5 0.1 -7.2 -7.6 03/24/2007 20:50:00 8.4 0.7 9.9 6.5 8.5 0.7 9.9 6.8 7.9 0.9 9.9 5.3 282 5 278 165 -7.4 0 -7.2 -7.6 03/24/2007 21:00:00 8.1 0.6 9.9 6.8 8.2 0.6 9.9 6.8 7 1 9.1 4.2 285 6 287 165 -7.5 0.1 -7.2 -7.6 03/24/2007 21:10:00 8.6 0.6 9.9 6.5 8.7 0.7 10.3 6.1 8 0.9 9.9 4.9 283 6 287 165 -7.4 0 -7.2 -7.6 03/24/2007 21:20:00 7.8 0.9 9.1 5.3 8 0.9 9.5 5.3 7.5 1 9.9 4.2 278 6 284 165 -7.4 0.1 -7.2 -7.6 03/24/2007 21:30:00 8.2 0.6 9.5 6.5 8.2 0.6 9.9 6.5 7.7 0.8 9.9 5.3 282 4 281 165 -7.5 0 -7.2 -7.6 03/24/2007 21:40:00 8.4 0.6 9.9 6.5 8.5 0.6 9.9 6.5 8 0.7 9.5 6.1 282 5 282 165 -7.5 0 -7.2 -7.6 03/24/2007 21:50:00 9.3 0.5 10.7 8 9.4 0.5 11.1 8 8.5 0.7 10.3 6.5 287 4 289 165 -7.5 0 -7.2 -7.9 03/24/2007 22:00:00 9.9 0.5 11.1 8.4 10.1 0.5 11.1 8.8 8.9 0.8 10.7 6.1 287 5 287 165 -7.5 0 -7.2 -7.9 03/24/2007 22:10:00 9.8 0.5 11.1 8.4 9.9 0.5 11.1 8.8 8.2 0.9 10.3 5.7 290 5 288 165 -7.4 0 -7.2 -7.6 03/24/2007 22:20:00 9.3 0.5 10.7 8 9.4 0.5 11.1 8.4 8.4 0.9 10.3 6.1 288 5 286 165 -7.3 0.1 -7 -7.4 03/24/2007 22:30:00 8.5 0.6 10.3 7.2 8.6 0.6 10.3 7.2 7.4 1 9.9 4.9 288 4 292 165 -7.3 0 -7 -7.4 03/24/2007 22:40:00 8 0.6 9.1 6.5 8.1 0.6 9.1 6.5 7.6 0.7 9.5 5.7 287 3 289 165 -7.3 0 -7 -7.4 03/24/2007 22:50:00 6.4 0.5 7.6 5.3 6.5 0.5 8 5.7 6.1 0.5 7.2 4.9 287 3 289 165 -7.3 0 -7.2 -7.6 03/24/2007 23:00:00 7.6 0.8 10.3 6.1 7.8 0.9 10.3 6.1 7.5 0.9 10.7 4.9 280 3 289 165 -7.4 0 -7.2 -7.6 03/24/2007 23:10:00 8.7 1.1 11.1 4.9 9.1 0.8 11.5 7.2 8.9 0.9 11.1 6.5 277 6 273 165 -6.8 0.1 -6.6 -7.6 03/24/2007 23:20:00 7.8 1.1 10.3 3.8 8.2 0.9 10.7 6.1 8.1 0.9 10.7 5.3 276 8 272 165 -6.7 0 -6.6 -6.8 03/24/2007 23:30:00 7.3 0.7 9.1 5.3 7.6 0.5 9.1 6.1 7.2 0.6 8.8 4.9 277 7 290 165 -6.9 0.1 -6.6 -7.2 03/24/2007 23:40:00 6.9 1.1 9.9 4.2 7.3 0.8 9.9 5.7 7.2 0.9 10.7 4.9 276 6 275 165 -6.9 0.1 -6.6 -7.2 03/24/2007 23:50:00 5.9 0.7 7.2 3.4 6.3 0.4 7.6 5.3 6.3 0.5 7.6 4.9 274 5 279 165 -7.2 0 -6.8 -7.2 03/25/2007 00:00:00 6.3 0.8 7.6 3 6.7 0.6 8.8 5.3 6.5 0.9 8.8 3.8 279 9 272 165 -6.8 0.2 -6.6 -7.4 03/25/2007 00:10:00 7 0.7 9.1 5.7 7.2 0.8 9.5 5.7 7.1 0.8 9.1 5.7 277 3 275 165 -6.9 0.1 -6.6 -7.2 03/25/2007 00:20:00 8.9 1 11.5 6.1 9.1 1 11.1 6.8 9.1 0.8 11.5 7.2 279 5 286 165 -6.4 0.2 -5.9 -6.8 03/25/2007 00:30:00 10 0.6 11.5 8 10.1 0.6 11.5 8.4 8.6 1.1 11.1 6.1 288 6 290 165 -6 0 -5.7 -6.4 03/25/2007 00:40:00 8.3 1 10.7 5.7 8.3 1 10.7 5.7 7.4 1.2 10.7 4.2 286 7 283 165 -6 0 -5.7 -6.4 03/25/2007 00:50:00 6.7 0.6 8.4 5.3 6.8 0.6 8.4 5.3 6.3 1 8.8 3.8 283 6 273 165 -6.5 0.1 -6.1 -6.8 03/25/2007 01:00:00 7.2 0.3 8 6.1 7.3 0.4 8.4 6.5 6.9 0.6 8.4 5.3 283 4 281 165 -6.6 0 -6.4 -6.8 03/25/2007 01:10:00 6.3 1.2 8.8 4.2 6.4 1.2 9.1 4.2 6.5 1.1 9.1 4.6 280 5 280 165 -6.3 0.1 -6.1 -6.8 03/25/2007 01:20:00 6 0.8 8 3.8 6.1 0.8 8 4.2 5.8 0.7 8.4 4.2 283 6 278 165 -6.3 0.1 -6.1 -6.6 03/25/2007 01:30:00 5.6 0.8 8 3.4 5.7 0.8 7.6 3.8 5.4 1 7.2 3 282 9 291 165 -6.4 0.1 -6.1 -6.6 03/25/2007 01:40:00 4.5 0.9 7.6 2.3 5.1 0.9 8.4 2.6 4.9 0.8 7.6 2.6 261 9 251 165 -6 0.1 -5.7 -6.6 03/25/2007 01:50:00 4.5 1.5 8.4 1.1 4.9 1.7 8.8 1.5 4.9 1.6 8.4 1.9 238 32 276 165 -5.8 0.1 -5.5 -6.1 03/25/2007 02:00:00 2.6 1.5 6.8 0.4 2.9 1.6 6.8 0.4 2.9 1.5 7.2 0.4 228 43 279 165 -6 0 -5.7 -6.4 03/25/2007 02:10:00 3.8 1.2 6.8 1.1 4.4 1.3 7.2 1.5 4.2 1.2 6.8 1.1 261 17 246 165 -5.8 0 -5.5 -5.7 03/25/2007 02:20:00 3.8 2.2 9.5 0.4 4.1 2.3 11.1 0.4 3.8 2 8.4 0.4 224 49 271 165 -6 0.2 -5.5 -6.4 03/25/2007 02:30:00 4.8 1.7 9.1 0.4 5.1 1.7 9.1 0.4 4.9 1.5 9.1 0.7 265 29 274 165 -5.6 0.2 -5.5 -5.9 03/25/2007 02:40:00 8.6 1.5 11.1 4.6 9 1.2 11.5 5.7 8.5 1.3 11.5 5.3 275 7 272 165 -5.3 0.2 -4.8 -6.1 03/25/2007 02:50:00 8.2 1.8 12.6 4.2 8.6 1.5 13.3 5.7 8 1.5 13.7 4.9 276 9 285 165 -5 0 -4.6 -5.3 03/25/2007 03:00:00 10.1 1.5 13.3 6.1 10.5 1.4 14.1 6.8 9.9 1.7 13.7 4.6 275 8 275 165 -4.8 0 -4.6 -5.3 03/25/2007 03:10:00 11.4 1.4 15.3 6.8 11.3 1.4 15.3 6.8 10.2 1.5 14.1 5.7 282 9 289 165 -4.8 0 -4.6 -5 03/25/2007 03:20:00 13.1 0.9 15.6 10.7 13.1 1 15.6 10.7 11.1 1.4 14.5 7.2 285 8 289 165 -4.8 0 -4.6 -5 03/25/2007 03:30:00 13.5 1.1 16.1 10.3 13.5 1.1 16.4 10.3 10.5 1.6 15.3 6.5 287 9 288 165 -4.7 0 -4.6 -4.8 03/25/2007 03:40:00 10.8 1.2 13.7 7.6 10.8 1.3 14.1 7.2 8.7 1.5 13.3 5.3 288 9 292 165 -4.8 0 -4.6 -5 03/25/2007 03:50:00 10.3 1.1 12.6 7.2 10.3 1.1 13 7.2 8.7 1.7 12.6 4.9 286 9 273 165 -4.8 0.1 -4.4 -5.3 03/25/2007 04:00:00 9.1 1.1 11.5 4.9 9.1 1.2 11.8 5.3 8.2 1.5 11.8 3.8 283 9 261 165 -4.8 0 -4.6 -5 03/25/2007 04:10:00 8.4 0.9 10.3 6.5 8.4 0.9 10.7 6.1 7.5 1.4 10.3 4.6 287 7 291 165 -4.9 0 -4.8 -5.3 03/25/2007 04:20:00 6.4 1 9.1 4.2 6.5 1 9.1 4.2 6.2 0.8 9.1 4.2 279 8 296 165 -5.2 0.1 -4.8 -5.5 03/25/2007 04:30:00 6.3 0.9 8.8 3.8 6.5 0.7 8.4 4.9 6.3 0.8 8 4.6 278 7 284 165 -5.3 0 -5 -5.5 03/25/2007 04:40:00 7.2 1 9.9 4.9 7.2 1.1 10.3 4.9 6.7 1.3 9.9 3.8 284 6 282 165 -5.3 0.1 -5 -5.7 03/25/2007 04:50:00 6.8 1.6 9.9 2.6 7 1.4 9.9 3.8 6.5 1.3 9.9 4.2 279 10 291 165 -5.2 0 -5 -5.3 03/25/2007 05:00:00 6 0.8 7.6 4.2 6 0.8 8 4.2 5.3 1 7.6 3.4 288 7 297 165 -5.3 0 -5 -5.5 03/25/2007 05:10:00 7 1 9.5 4.9 7 1 9.1 4.9 5.8 1.2 9.1 3.4 291 9 295 165 -5.2 0 -4.8 -5.5 03/25/2007 05:20:00 5.5 1.1 8.8 2.6 5.5 1.1 8 2.3 4.5 1.1 7.2 2.3 291 10 279 165 -5.2 0.1 -4.8 -5.5 03/25/2007 05:30:00 5.5 0.5 6.8 4.2 5.5 0.5 6.8 4.2 4.6 0.7 6.1 3 291 6 268 165 -5.2 0 -5 -5.5 03/25/2007 05:40:00 5.6 1 8 3 5.7 1 7.6 3.4 5.1 1 7.6 3.4 283 9 274 165 -4.9 0 -4.6 -5.5 03/25/2007 05:50:00 6.9 0.9 9.1 4.6 7 1 9.1 4.2 6 1.1 8.4 3.4 287 8 297 165 -5.1 0 -4.8 -5.5 03/25/2007 06:00:00 5.4 1 8 3 5.4 1 7.6 3 4.6 1 8 2.6 292 12 301 165 -5.1 0.1 -4.8 -5.5 03/25/2007 06:10:00 5.1 1 7.6 2.6 5.3 0.9 7.6 2.6 5.1 0.9 7.6 2.3 278 8 281 165 -5.5 0 -5.3 -5.7 03/25/2007 06:20:00 5.7 1.3 8.8 3 6 1.2 8.8 3.4 5.6 1 8.4 3.4 278 10 298 165 -5.6 0 -5.5 -5.9 03/25/2007 06:30:00 6.4 1.3 9.5 3 6.6 1 9.5 4.6 6.1 1 8.8 3.8 279 12 287 165 -5.4 0 -5 -5.7 03/25/2007 06:40:00 6.2 0.9 8.4 3.4 6.5 0.8 8.4 4.2 6.1 1 8 3.4 276 9 276 165 -5.5 0 -5.5 -5.7 03/25/2007 06:50:00 7.5 1.1 10.3 5.3 7.5 1.1 10.3 4.9 6.4 1.1 8.8 3.4 285 11 293 165 -5.5 0.1 -5.3 -5.9 03/25/2007 07:00:00 6.9 1.2 9.9 3 7 1.2 9.9 4.2 6.5 1.2 9.5 3.4 280 10 286 165 -5.4 0 -5.3 -5.7 03/25/2007 07:10:00 8.5 1.6 11.5 3.8 8.5 1.6 11.5 3.4 7.1 1.4 11.5 3.4 292 14 293 165 -5.3 0.1 -5 -5.7 03/25/2007 07:20:00 7.7 1.4 11.5 4.6 7.7 1.4 11.1 4.6 6.5 1.2 10.3 3.4 296 15 294 165 -5.2 0 -5 -5.5 03/25/2007 07:30:00 9 1.2 11.5 5.7 8.9 1.2 11.5 5.7 7.4 1.4 12.2 3.8 299 13 312 165 -5.1 0 -4.8 -5.5 03/25/2007 07:40:00 10.1 1.8 15.6 6.8 10 1.8 15.6 6.8 8.9 1.6 14.1 5.7 301 12 298 165 -5 0 -4.8 -5.3 03/25/2007 07:50:00 12 1 14.9 9.1 11.9 1.1 15.3 9.1 9.8 1.5 14.1 6.5 295 12 284 165 -5 0 -5 -5.3 03/25/2007 08:00:00 11.8 2 16.8 8 11.8 2.1 16.4 7.6 9.8 1.4 14.5 7.2 302 12 289 165 -4.9 0 -4.6 -5.5 03/25/2007 08:10:00 11 1.2 14.1 8 10.9 1.2 14.1 8 9.9 1.4 13 6.5 305 9 291 165 -4.8 0 -4.6 -5.3 03/25/2007 08:20:00 12.3 1.6 16.1 8.4 12.2 1.7 16.1 8.4 10 1.5 14.5 6.5 298 11 282 165 -4.8 0 -4.6 -5 03/25/2007 08:30:00 11.3 1.7 14.9 7.6 11.3 1.7 15.6 7.6 9.2 1.5 13.3 5.7 294 14 294 165 -4.7 0 -4.6 -5 03/25/2007 08:40:00 10.1 1.1 13.3 7.2 10 1.1 13.3 7.2 8.6 1.1 11.8 5.3 299 13 284 165 -4.7 0 -4.4 -4.8 03/25/2007 08:50:00 10.3 1.4 14.1 7.6 10.3 1.5 14.1 7.2 8.6 1.4 13.3 5.7 295 13 287 165 -4.6 0 -4.4 -4.8 03/25/2007 09:00:00 11.1 1.2 14.1 8.4 11.1 1.2 14.1 8 8.7 1.2 12.2 5.3 291 11 294 165 -4.5 0 -4.4 -4.8 03/25/2007 09:10:00 12.5 1.3 16.4 9.1 12.4 1.3 16.4 9.5 9.6 1.3 13.7 6.8 293 12 298 165 -4.4 0 -4.4 -4.6 03/25/2007 09:20:00 15.1 1.2 17.6 11.8 15.2 1.2 17.9 11.1 11.5 1.8 16.8 6.8 289 9 293 165 -4.5 0 -4.4 -4.6 03/25/2007 09:30:00 13.1 1.2 15.3 9.9 13.1 1.3 15.6 9.9 10.2 1.6 14.1 6.8 291 10 288 165 -4.3 0 -4.2 -4.6 03/25/2007 09:40:00 13.2 1.5 15.6 8.4 13.2 1.5 16.1 8.8 10.7 1.8 14.9 6.5 289 10 278 165 -4.2 0 -3.9 -4.6 03/25/2007 09:50:00 12.8 1.5 16.4 9.1 12.8 1.6 16.1 9.1 10.1 1.5 15.3 6.5 292 12 294 165 -4 0 -3.9 -4.4 03/25/2007 10:00:00 11.1 1.3 14.5 6.8 11.1 1.3 14.9 7.2 9.4 1.5 13 5.7 299 12 300 165 -3.8 0 -3.3 -4.4 03/25/2007 10:10:00 9.2 1.3 12.2 6.1 9.1 1.3 12.2 5.7 7.9 1.6 12.6 4.6 303 11 281 165 -3.6 0.1 -3.3 -3.9 03/25/2007 10:20:00 8.4 1 11.1 5.7 8.3 1 11.1 5.7 7 1.3 11.5 4.2 303 9 301 165 -3.4 0 -3.3 -3.7 03/25/2007 10:30:00 8.4 1.1 11.1 5.7 8.3 1.1 10.7 5.3 6.9 1.1 9.9 3.8 294 12 299 165 -3.4 0 -3.3 -3.7 03/25/2007 10:40:00 8.4 1.4 11.8 5.3 8.4 1.4 12.2 5.7 7.4 1.7 11.8 3.8 286 11 294 165 -3.2 0 -3 -3.7 03/25/2007 10:50:00 9.7 1.7 13.3 5.3 9.7 1.7 13.7 4.9 8.6 1.9 13 3.8 292 13 277 165 -3.3 0.1 -3 -3.9 03/25/2007 11:00:00 7.7 1 9.9 5.7 7.7 1 9.9 5.7 6.7 1.2 10.3 4.2 295 12 310 165 -3.1 0.1 -2.8 -3.5 03/25/2007 11:10:00 7.2 0.9 10.3 4.9 7.4 1 11.1 4.6 6.7 1.2 9.9 4.2 283 9 273 165 -3 0.1 -2.8 -3.5 03/25/2007 11:20:00 8 1 10.3 5.3 8.1 1 10.7 5.7 7.3 1.1 9.9 4.6 285 10 312 165 -3.2 0.2 -2.8 -3.7 03/25/2007 11:30:00 8.3 1.5 11.5 3 8.5 1.4 11.8 4.2 8 1.5 11.8 4.2 279 8 272 165 -3.2 0.1 -2.8 -3.5 03/25/2007 11:40:00 7.2 1.5 10.3 4.2 7.2 1.5 10.7 4.6 6.3 1.7 10.7 3 291 13 282 165 -3.3 0.1 -3 -3.5 03/25/2007 11:50:00 6.7 1.2 9.9 4.2 6.7 1.2 9.9 4.2 6.1 1.4 9.5 3.4 283 9 281 165 -3 0 -2.8 -3.3 03/25/2007 12:00:00 6.2 1 8.8 3.4 6.5 0.9 9.1 3.4 6.2 0.9 8.4 3.4 276 12 244 165 -2.9 0 -2.6 -3 03/25/2007 12:10:00 5.9 1.2 8.8 2.6 6.1 1.2 9.9 3 5.8 1.4 9.5 2.3 275 12 274 165 -2.4 0.3 -1.7 -3 03/25/2007 12:20:00 4.1 0.7 6.1 2.6 4.2 0.7 7.2 2.6 3.8 0.8 6.8 1.9 282 17 254 165 -1.4 0.3 -0.8 -2.6 03/25/2007 12:30:00 4.4 1.2 7.2 1.9 4.6 1.2 8 1.9 4 1.3 7.6 1.5 277 15 262 165 -0.6 0.2 -0.3 -1.2 03/25/2007 12:40:00 8.3 2 12.2 3.8 8.4 2 12.2 3.8 7.8 1.9 13.3 4.2 280 10 278 165 -1.8 0.2 -1.2 -2.1 03/25/2007 12:50:00 7.3 1.3 10.3 4.2 7.3 1.3 9.5 3.8 6.4 1.2 9.1 3.4 290 13 267 165 -1.8 0.2 -1.4 -2.6 03/25/2007 13:00:00 7 1.7 11.8 3 7 1.7 11.8 3.4 5.8 1.5 10.7 3 295 12 298 165 -2.1 0.1 -1.7 -2.6 03/25/2007 13:10:00 7.6 1.4 11.1 4.2 7.6 1.3 10.7 4.2 6.4 1.3 9.9 3 294 12 291 165 -2 0.2 -1.7 -2.6 03/25/2007 13:20:00 7.5 1.9 11.8 3.4 7.5 1.9 11.5 3.8 6.1 1.5 9.9 3.4 295 11 294 165 -1.7 0.2 -1.4 -2.6 03/25/2007 13:30:00 7.6 1.3 10.3 4.6 7.6 1.2 9.9 4.6 6.4 1.2 9.9 3.8 291 13 313 165 -2.2 0 -1.9 -2.6 03/25/2007 13:40:00 5.9 0.9 7.6 3.8 5.9 0.9 8.4 3.8 5.1 1 7.6 3 291 11 269 165 -2.1 0 -1.9 -2.6 03/25/2007 13:50:00 5.4 1 7.6 2.6 5.4 0.9 7.6 3 4.5 0.9 7.6 2.3 294 13 285 165 -1.9 0.1 -1.7 -2.1 03/25/2007 14:00:00 5.3 1.1 7.6 2.6 5.4 1.1 7.6 3 4.8 1.1 7.2 2.3 289 11 297 165 -2 0 -1.9 -2.1 03/25/2007 14:10:00 7.4 1.8 11.5 3.4 7.6 1.8 11.5 3.8 7 1.8 11.1 2.6 284 12 282 165 -2.1 0 -1.9 -2.4 03/25/2007 14:20:00 8.3 1.1 11.5 5.7 8.4 1.2 11.1 5.7 6.9 1.3 11.1 4.6 298 11 296 165 -1.8 0.1 -1.4 -2.4 03/25/2007 14:30:00 8.1 1 11.5 5.7 8.1 1 11.5 5.3 7.1 1.3 11.5 4.9 306 11 313 165 -1.6 0.1 -1.2 -1.9 03/25/2007 14:40:00 7.8 1.1 10.3 5.3 7.8 1.2 10.3 4.9 6.5 1.2 11.5 3.8 299 9 310 165 -1.8 0 -1.7 -2.1 03/25/2007 14:50:00 7.6 0.8 10.3 6.1 7.6 0.8 9.9 6.1 6.6 1 9.9 4.2 305 9 319 165 -2.1 0.1 -1.7 -2.4 03/25/2007 15:00:00 7.5 1.3 11.5 5.3 7.5 1.2 11.1 5.3 6.1 1.2 10.3 3.8 296 9 301 165 -2 0 -1.7 -2.1 03/25/2007 15:10:00 8.5 1.2 11.8 4.6 8.5 1.2 11.5 4.6 7 1.4 12.2 4.2 302 9 313 165 -1.8 0.2 -1.4 -2.1 03/25/2007 15:20:00 8.2 1 11.5 5.7 8.2 1 10.7 5.7 6.9 1.3 10.7 4.2 297 10 306 165 -1.4 0.2 -1.2 -2.1 03/25/2007 15:30:00 8.3 1.1 10.3 5.3 8.3 1.2 10.3 5.3 7.1 1.6 10.3 3.8 290 7 286 165 -2 0.2 -1.4 -2.6 03/25/2007 15:40:00 8.3 0.9 10.7 6.1 8.3 0.9 11.1 6.1 7 1.2 10.7 4.2 288 8 279 165 -2.4 0.1 -2.1 -2.6 03/25/2007 15:50:00 9.6 1.6 12.6 5.7 9.7 1.6 12.6 5.7 7.8 1.8 12.2 3.8 291 7 283 165 -2.5 0 -2.4 -2.6 03/25/2007 16:00:00 9.4 1.5 12.6 5.7 9.5 1.5 12.6 5.7 7.4 1.6 12.6 4.6 291 7 293 165 -2.5 0 -2.1 -2.6 03/25/2007 16:10:00 11.2 0.8 13.3 8 11.3 0.8 13 8 8.6 1.2 11.8 5.7 294 7 293 165 -2.3 0 -2.1 -2.6 03/25/2007 16:20:00 9.3 1 12.2 6.8 9.3 1 12.2 6.8 7.3 1 10.3 4.9 297 9 255 165 -2.2 0 -2.1 -2.6 03/25/2007 16:30:00 9 1 11.5 6.5 9 1 11.5 6.5 6.9 1 10.7 4.9 295 9 299 165 -2.1 0.1 -1.9 -2.6 03/25/2007 16:40:00 8.3 1.1 11.5 5.7 8.4 1.1 11.5 5.7 7.4 1.4 11.5 4.6 291 10 281 165 -1.7 0 -1.4 -1.9 03/25/2007 16:50:00 6.8 1 9.5 4.2 6.8 1 9.5 4.2 5.6 1.1 10.3 3 296 9 290 165 -1.4 0.1 -1.2 -1.7 03/25/2007 17:00:00 7 1 9.5 3.8 7 1 9.5 3.8 6 1.1 9.5 3 290 12 297 165 -1.4 0 -1.2 -1.7 03/25/2007 17:10:00 6.4 0.9 8.4 4.2 6.5 0.9 8.4 4.6 6 1.1 8 2.6 282 7 277 165 -1.2 0.1 -0.8 -1.4 03/25/2007 17:20:00 6 0.7 7.2 3.4 6 0.7 7.6 4.2 5.8 0.7 7.2 4.2 281 6 277 165 -1.2 0.1 -1 -1.4 03/25/2007 17:30:00 5.2 1 7.2 2.3 5.6 0.7 7.2 3.8 5.4 0.8 7.2 3.8 274 8 286 165 -1.2 0 -0.8 -1.4 03/25/2007 17:40:00 3.8 0.7 5.3 2.3 4 0.6 5.3 2.3 3.8 0.6 5.3 2.3 276 10 279 165 -0.9 0.1 -0.8 -1.2 03/25/2007 17:50:00 3.6 0.6 4.9 1.5 3.6 0.6 4.9 1.9 3.5 0.7 4.9 1.9 283 5 279 165 -0.8 0 -0.5 -1.2 03/25/2007 18:00:00 2 0.6 3.4 0.4 2.2 0.6 3.4 0.7 2.2 0.6 3.8 1.1 277 7 277 165 -0.9 0.2 -0.5 -1.7 03/25/2007 18:10:00 0.7 0.5 1.9 0.4 0.8 0.5 2.3 0.4 0.8 0.5 2.3 0.4 254 15 270 165 -1 0 -0.8 -1.2 03/25/2007 18:20:00 0.5 0.3 1.9 0.4 0.5 0.4 1.9 0.4 0.5 0.4 1.9 0.4 293 98 150 165 -1 0.1 -0.8 -1.2 03/25/2007 18:30:00 1.2 0.6 2.3 0.4 1.3 0.5 2.3 0.4 1.3 0.6 2.6 0.4 183 10 182 165 -1.2 0 -1 -1.4 03/25/2007 18:40:00 1.8 0.5 3 1.1 1.9 0.4 3 1.1 1.9 0.5 3 0.7 174 10 181 165 -1.4 0.1 -1 -1.7 03/25/2007 18:50:00 1.9 0.3 2.6 0.7 1.8 0.3 2.6 0.7 1.9 0.4 2.6 0.7 178 11 179 165 -1.6 0 -1.4 -1.9 03/25/2007 19:00:00 2.1 0.3 3 1.5 2.1 0.3 2.6 1.5 2.1 0.3 2.6 1.5 174 7 183 165 -1.9 0 -1.7 -2.1 03/25/2007 19:10:00 2.7 0.2 3 2.3 2.7 0.2 3 2.3 2.7 0.2 3.4 2.3 190 4 183 165 -2 0 -1.9 -2.1 03/25/2007 19:20:00 2.9 0.3 3.8 2.3 3 0.3 3.8 2.3 3 0.3 3.8 2.3 199 6 207 165 -2.2 0 -2.1 -2.6 03/25/2007 19:30:00 3.6 0.4 4.6 2.6 3.6 0.4 4.6 2.6 3.6 0.4 4.6 2.6 200 5 196 165 -2.4 0 -2.1 -2.6 03/25/2007 19:40:00 4.2 0.6 5.3 2.6 4.1 0.6 5.3 2.6 4.2 0.7 5.3 2.6 191 4 179 165 -2.2 0 -2.1 -2.6 03/25/2007 19:50:00 4.4 0.4 5.7 3.4 4.3 0.4 5.3 3.4 4.6 0.5 5.7 3.8 192 5 187 165 -2.3 0 -2.1 -2.6 03/25/2007 20:00:00 4.9 0.7 6.5 3 4.8 0.7 6.5 3.4 5.1 0.7 6.5 3.4 191 3 189 165 -2.4 0 -2.1 -2.6 03/25/2007 20:10:00 4.1 0.5 5.3 3 4.1 0.4 5.3 3 4.4 0.4 5.3 3 187 5 192 165 -2.4 0.1 -2.1 -2.6 03/25/2007 20:20:00 3.6 0.6 4.9 2.6 3.6 0.5 4.9 2.6 3.8 0.6 5.3 2.6 189 8 180 165 -2.5 0 -2.4 -2.6 03/25/2007 20:30:00 3.9 0.6 5.3 2.6 3.8 0.5 4.9 3 4 0.6 5.7 3 177 8 172 165 -2.4 0.1 -2.1 -2.6 03/25/2007 20:40:00 3.9 0.4 4.9 2.6 3.9 0.4 4.9 2.6 4 0.5 5.3 2.6 188 7 182 165 -2.5 0 -2.4 -2.6 03/25/2007 20:50:00 3.5 0.4 4.9 2.3 3.5 0.4 4.6 2.6 3.8 0.4 4.9 2.6 173 8 171 165 -2.5 0 -2.4 -2.8 03/25/2007 21:00:00 3.5 0.4 4.2 2.6 3.5 0.3 4.2 2.6 3.8 0.3 4.6 3 178 6 184 165 -2.5 0 -2.4 -2.8 03/25/2007 21:10:00 4.7 0.6 5.7 3 4.6 0.6 6.1 3 4.8 0.6 6.1 3.4 182 5 189 165 -2.8 0 -2.6 -3 03/25/2007 21:20:00 5.6 0.4 6.8 4.6 5.5 0.4 6.5 4.6 5.9 0.4 6.8 4.9 180 3 177 165 -2.8 0 -2.8 -3 03/25/2007 21:30:00 5.7 0.5 7.2 4.2 5.6 0.5 6.8 4.2 5.8 0.5 7.2 4.6 189 5 193 165 -2.8 0.1 -2.6 -3 03/25/2007 21:40:00 4.8 0.6 6.5 3.4 4.7 0.6 6.1 3.4 4.9 0.7 6.8 3.4 187 4 192 165 -2.8 0 -2.6 -3 03/25/2007 21:50:00 5.3 0.8 7.6 3.4 5.3 0.8 7.6 3.4 5.3 0.9 8 3.8 198 6 198 165 -2.9 0 -2.6 -3 03/25/2007 22:00:00 5.8 0.7 8.8 4.2 5.8 0.7 8.4 3.8 6 0.6 8 4.2 197 8 200 165 -2.9 0 -2.8 -3 03/25/2007 22:10:00 4.6 0.7 6.8 3 4.7 0.7 6.8 3.4 4.6 0.7 6.8 3 201 6 193 165 -3.1 0.1 -2.8 -3.3 03/25/2007 22:20:00 4.8 0.6 6.1 3 4.9 0.5 6.1 3 5 0.6 6.5 3.4 202 6 202 165 -3 0.1 -2.8 -3.3 03/25/2007 22:30:00 5.4 0.5 6.8 4.2 5.5 0.5 6.8 4.2 5.4 0.6 6.8 3.8 195 8 200 165 -3 0 -2.8 -3.3 03/25/2007 22:40:00 5.5 0.7 6.8 3.4 5.4 0.7 6.5 3.4 5.6 0.8 7.2 3.4 184 5 178 165 -3 0 -2.8 -3 03/25/2007 22:50:00 7.2 0.5 8 5.7 6.9 0.4 7.6 5.3 7.2 0.6 8.4 5.7 176 3 175 165 -2.9 0 -2.8 -3.3 03/25/2007 23:00:00 7.1 0.3 8 6.1 6.7 0.3 7.6 6.1 7.3 0.4 8 6.5 175 4 178 165 -2.9 0 -2.8 -3.3 03/25/2007 23:10:00 7.1 0.5 8.4 5.3 6.8 0.5 8 5.3 7.1 0.6 8.8 5.3 181 3 179 165 -2.9 0 -2.8 -3.3 03/25/2007 23:20:00 7.6 0.4 8.8 6.1 7.3 0.4 8.4 6.1 7.7 0.4 9.1 6.5 176 4 178 165 -2.9 0 -2.8 -3.3 03/25/2007 23:30:00 6.2 0.4 7.2 4.9 5.9 0.4 7.2 4.9 6.3 0.4 7.2 5.3 165 12 168 165 -2.9 0 -2.8 -3 03/25/2007 23:40:00 5.9 0.4 6.8 4.6 5.6 0.4 6.8 4.6 5.9 0.4 6.8 4.6 159 12 157 165 -2.9 0 -2.8 -3 03/25/2007 23:50:00 5.5 0.4 6.1 4.2 5.3 0.3 6.1 4.6 5.5 0.4 6.5 4.6 156 9 155 165 -3 0 -2.8 -3.3 03/26/2007 00:00:00 5 0.4 6.5 4.2 4.8 0.4 6.1 3.8 5.1 0.4 6.1 4.2 155 7 151 165 -3 0 -2.8 -3.3 03/26/2007 00:10:00 5.9 0.7 8 4.6 5.7 0.6 8 4.6 6.1 0.7 8.8 4.9 153 8 157 165 -2.6 0.1 -2.6 -3 03/26/2007 00:20:00 7.4 0.5 8.8 5.7 7.1 0.5 8.4 5.7 7.4 0.5 8.8 5.7 158 15 165 165 -2.5 0 -2.1 -2.6 03/26/2007 00:30:00 6.1 0.6 7.6 4.9 5.9 0.5 7.2 4.6 6.1 0.5 7.2 4.9 162 10 171 165 -2.4 0.1 -2.1 -2.6 03/26/2007 00:40:00 5.8 1.1 8.4 4.2 5.6 1 8.4 3.8 5.7 1 8.4 4.2 156 8 165 165 -2.5 0 -2.1 -2.6 03/26/2007 00:50:00 8.2 1.1 10.3 5.7 8.1 1.1 9.9 5.7 8.5 1.1 10.3 5.7 154 6 158 165 -2.1 0.1 -1.7 -2.6 03/26/2007 01:00:00 8.8 0.4 9.9 7.6 8.6 0.4 9.5 7.2 9.1 0.4 9.9 8 152 11 174 165 -2.1 0 -1.9 -2.1 03/26/2007 01:10:00 8.7 0.4 9.5 6.8 8.5 0.4 9.5 7.2 8.9 0.4 9.9 7.6 153 10 156 165 -2.2 0 -1.9 -2.4 03/26/2007 01:20:00 9.5 0.6 11.5 8 9.3 0.6 11.1 8 9.5 0.6 11.8 8 153 8 166 165 -2.1 0 -1.9 -2.4 03/26/2007 01:30:00 10.4 0.8 12.6 8.4 10.1 0.8 12.2 8.4 10.6 0.8 12.6 7.6 148 22 82 165 -2 0 -1.9 -2.1 03/26/2007 01:40:00 9 0.6 10.3 7.6 8.7 0.5 10.3 7.6 9.2 0.6 10.7 8 152 15 153 165 -2.1 0 -1.9 -2.4 03/26/2007 01:50:00 9.7 0.5 11.1 8.8 9.4 0.4 11.1 8.8 10 0.4 11.1 9.1 153 7 139 165 -2 0 -1.9 -2.1 03/26/2007 02:00:00 9.3 0.5 10.7 8 9.2 0.4 10.7 7.6 9.5 0.4 10.7 8.4 150 3 147 165 -1.8 0 -1.7 -1.9 03/26/2007 02:10:00 9.8 0.4 10.7 8.4 9.7 0.4 10.7 8.4 9.9 0.4 11.1 8.4 148 3 148 165 -1.7 0 -1.4 -1.9 03/26/2007 02:20:00 10.7 0.7 12.2 8.4 10.6 0.7 12.2 8 10.8 0.8 12.2 8.4 148 3 148 165 -1.4 0.1 -1.2 -1.7 03/26/2007 02:30:00 12 1 14.5 9.5 12 1 14.1 9.1 12.1 1.2 14.9 8.8 147 5 145 165 -1.2 0 -1 -1.4 03/26/2007 02:40:00 12.7 1 14.9 9.1 12.5 1 14.9 9.1 12.7 1.1 14.9 9.1 147 5 148 165 -1.1 0 -0.8 -1.2 03/26/2007 02:50:00 13.6 1 16.1 10.7 13.3 1 15.6 10.3 13.6 1.1 16.1 9.9 145 5 148 165 -1 0 -0.8 -1.2 03/26/2007 03:00:00 13.5 1.3 16.4 10.7 13.2 1.2 15.6 10.7 13.4 1.3 16.4 10.3 146 8 143 165 -0.8 0.1 -0.5 -1.2 03/26/2007 03:10:00 14.5 0.8 16.4 12.2 14.1 0.8 16.4 11.8 14.4 0.8 16.4 11.5 150 7 146 165 -0.6 0 -0.5 -0.8 03/26/2007 03:20:00 14.3 0.8 16.4 12.6 14 0.8 16.1 11.8 14.1 1 16.8 11.1 140 7 139 165 -0.6 0 -0.5 -0.8 03/26/2007 03:30:00 14 1.1 16.8 11.1 13.8 1.1 16.4 11.1 13.8 1.2 16.8 9.9 137 6 135 165 -0.4 0 -0.1 -0.5 03/26/2007 03:40:00 13.8 0.9 16.1 10.7 13.6 0.9 15.6 10.7 13.7 0.9 15.6 10.7 143 7 149 165 -0.2 0 -0.1 -0.3 03/26/2007 03:50:00 11.5 1 13.7 9.5 11.4 1 13.7 9.5 11.6 1 13.7 8.8 148 5 144 165 -0.1 0 0.2 -0.3 03/26/2007 04:00:00 7.9 1.2 10.7 5.7 7.8 1.2 10.3 5.7 8 1.2 10.7 5.7 153 0 153 165 -0.2 0 -0.1 -0.3 03/26/2007 04:10:00 5.5 0.6 6.5 4.2 5.6 0.5 6.5 4.2 5.8 0.6 6.8 3.8 153 0 153 165 -0.3 0 -0.1 -0.5 03/26/2007 04:20:00 3.8 0.6 5.3 2.3 4.1 0.6 5.3 2.6 4.1 0.6 5.3 2.6 153 0 153 165 -0.3 0 -0.3 -0.5 03/26/2007 04:30:00 4.3 0.6 5.3 2.6 4.5 0.5 5.7 3 4.8 0.4 6.1 3.8 153 0 154 165 -0.4 0 -0.3 -0.5 03/26/2007 04:40:00 4.9 0.3 5.7 4.2 5 0.3 5.7 4.2 5.3 0.3 6.1 4.6 153 0 153 165 -0.5 0 -0.3 -0.5 03/26/2007 04:50:00 4.1 0.3 4.9 3.4 4.1 0.3 4.9 3.4 4.5 0.4 5.3 3.8 153 0 153 165 -0.5 0 -0.3 -0.8 03/26/2007 05:00:00 3.6 0.4 4.6 2.6 3.7 0.4 4.6 2.6 3.9 0.4 4.6 2.6 153 0 154 165 -0.5 0 -0.3 -0.5 03/26/2007 05:10:00 3.5 0.6 4.9 2.3 3.6 0.5 4.6 2.3 3.8 0.5 4.9 2.3 153 0 154 165 -0.2 0 -0.1 -0.5 03/26/2007 05:20:00 4.1 0.4 4.9 3 4 0.4 4.9 2.6 4.4 0.4 5.3 3 153 0 154 165 -0.2 0 -0.1 -0.3 03/26/2007 05:30:00 3.9 0.3 4.9 3.4 3.9 0.3 4.6 3 4.4 0.4 5.3 3.4 153 0 154 165 -0.2 0 0.2 -0.3 03/26/2007 05:40:00 5.2 0.5 6.1 4.2 5 0.5 6.1 4.2 5.5 0.5 6.8 4.6 153 0 153 165 -0.2 0 -0.1 -0.3 03/26/2007 05:50:00 4 0.6 5.3 2.6 3.8 0.6 4.9 2.3 4.5 0.5 5.3 3.4 153 0 153 165 -0.2 0 -0.1 -0.5 03/26/2007 06:00:00 2 0.7 3.4 0.4 1.7 0.7 3.4 0.4 2.6 0.6 3.8 1.5 153 0 153 165 -0.3 0 -0.1 -0.5 03/26/2007 06:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0.2 1.9 0.4 153 0 165 165 -0.3 0 -0.3 -0.5 03/26/2007 06:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 153 0 165 165 -0.4 0 -0.3 -0.5 03/26/2007 06:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 153 0 165 165 -0.4 0 -0.3 -0.8 03/26/2007 06:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 153 0 165 165 -0.8 0 -0.5 -0.8 03/26/2007 06:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 153 0 165 165 -0.8 0 -0.5 -0.8 03/26/2007 07:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 153 0 165 165 -0.8 0 -0.8 -0.8 03/26/2007 07:10:00 2.6 4 11.1 0.4 2.7 4.1 11.8 0.4 2.3 3.5 10.3 0.4 153 0 154 165 -1 0.4 -0.8 -2.1 03/26/2007 07:20:00 11.4 1.1 14.5 8 11.7 1.1 14.5 8 9.7 1.4 12.6 6.1 153 0 154 165 -3 0.4 -2.1 -3.5 03/26/2007 07:30:00 11.6 1.1 14.5 9.1 11.9 1.1 14.5 9.5 9.3 1.4 13.7 6.5 153 0 154 165 -3.6 0 -3.3 -3.7 03/26/2007 07:40:00 12.3 1.3 16.8 9.1 12.6 1.3 16.8 8.8 9.5 1.4 13.7 6.5 153 0 154 165 -3.8 0 -3.5 -3.9 03/26/2007 07:50:00 12.7 1.4 15.6 9.5 13.1 1.5 16.4 9.5 9.6 1.9 15.3 5.3 153 0 154 165 -4 0.1 -3.7 -4.4 03/26/2007 08:00:00 14.2 1.2 16.8 11.1 14.6 1.3 17.6 11.5 10.2 2.1 16.8 6.8 153 0 154 165 -4.2 0 -3.9 -4.4 03/26/2007 08:10:00 14.1 1.5 17.6 9.1 14.6 1.5 17.9 9.5 10.9 2.1 17.2 6.5 154 0 154 165 -4.2 0 -3.9 -4.4 03/26/2007 08:20:00 12.9 1.2 16.1 9.9 13.3 1.2 16.1 10.3 9.5 1.5 14.5 6.8 154 0 154 165 -4.3 0 -4.2 -4.4 03/26/2007 08:30:00 12.9 1.4 16.4 9.5 13.3 1.4 16.8 9.9 10 1.7 16.1 6.1 154 0 154 165 -4.2 0 -3.9 -4.4 03/26/2007 08:40:00 13.3 1.5 16.4 9.1 13.5 1.5 16.4 9.5 9.8 1.7 15.3 6.1 154 0 154 165 -4.2 0 -4.2 -4.4 03/26/2007 08:50:00 13.9 1.9 19.1 8.8 14.1 2 19.9 8.8 11.2 2.5 19.1 6.5 181 53 154 165 -4.4 0 -4.2 -4.6 03/26/2007 09:00:00 13.2 1.6 18.3 9.1 13.4 1.6 18.3 9.5 11.1 2 17.2 6.1 298 10 304 165 -4.4 0 -4.4 -4.6 03/26/2007 09:10:00 13.6 1.3 17.6 9.9 13.7 1.3 17.6 10.7 11.6 2 18.7 7.6 296 12 302 165 -4.7 0.1 -4.4 -5 03/26/2007 09:20:00 16.1 1.4 19.5 12.2 16.3 1.5 19.9 12.2 12.5 2 17.6 8.8 292 11 298 165 -4.9 0 -4.6 -5 03/26/2007 09:30:00 15.1 1 17.9 12.2 15.2 1 18.3 11.8 14.2 1.5 17.6 9.1 302 10 291 165 -5.1 0.1 -4.8 -5.3 03/26/2007 09:40:00 14.9 1 18.3 12.2 14.9 1.1 18.3 12.2 14 1.7 17.9 9.5 301 10 293 165 -5.3 0 -5 -5.5 03/26/2007 09:50:00 14.3 1.5 17.9 10.7 14.3 1.5 18.3 10.7 13.6 2.1 17.9 7.2 301 12 310 165 -5.2 0 -5 -5.5 03/26/2007 10:00:00 14.2 1 16.8 11.8 14.3 1.1 17.2 11.8 12.7 2.1 18.3 7.6 301 11 309 165 -5 0.1 -4.6 -5.3 03/26/2007 10:10:00 14.4 1.2 17.2 11.5 14.7 1.2 17.9 11.5 12.2 1.9 17.9 8 297 12 295 165 -4.7 0.1 -4.6 -5 03/26/2007 10:20:00 14.8 1 18.3 12.2 15 1 17.9 11.8 10.7 2 16.8 6.8 292 12 306 165 -4.6 0 -4.4 -4.8 03/26/2007 10:30:00 14.1 1.2 17.6 11.1 14.2 1.3 17.6 11.1 10.8 2.2 15.6 6.8 293 14 311 165 -4.4 0 -4.4 -4.6 03/26/2007 10:40:00 15.7 1.7 19.9 11.1 15.7 1.8 19.9 11.1 12.3 2.1 17.6 7.6 292 15 307 165 -4.4 0 -4.2 -4.6 03/26/2007 10:50:00 15.9 1.6 20.2 11.1 16 1.7 20.2 11.5 12.8 2.2 17.9 6.8 293 14 286 165 -4.4 0 -4.4 -4.6 03/26/2007 11:00:00 14.3 1.3 17.2 10.3 14.4 1.4 17.6 10.3 11.4 2 16.8 6.8 290 15 283 165 -4.3 0 -4.4 -4.6 03/26/2007 11:10:00 14.5 1.6 18.7 10.3 14.7 1.7 18.7 10.7 10.9 1.7 16.8 7.6 292 14 299 165 -4.3 0 -4.2 -4.6 03/26/2007 11:20:00 14.3 1.4 17.2 10.3 14.5 1.4 17.6 10.3 11 1.6 16.4 6.8 287 15 295 165 -4.3 0 -4.2 -4.6 03/26/2007 11:30:00 12.5 1.2 15.3 9.1 12.8 1.2 15.3 9.5 11.2 1.7 15.3 6.8 280 12 280 165 -4.3 0 -4.2 -4.6 03/26/2007 11:40:00 13.1 1.5 17.9 8.8 13.4 1.5 18.3 8.8 11 1.6 14.9 7.2 284 13 300 165 -4.3 0 -4.2 -4.6 03/26/2007 11:50:00 14.1 1.6 18.3 9.9 14 1.6 18.7 9.9 10.6 1.7 17.2 7.2 288 15 285 165 -4.4 0 -4.2 -4.6 03/26/2007 12:00:00 14.9 1.5 19.1 10.7 14.8 1.5 18.7 11.1 11.2 1.8 16.8 6.8 288 13 287 165 -4.5 0 -4.4 -4.8 03/26/2007 12:10:00 14.9 1.6 18.7 10.7 15 1.5 18.7 10.7 11.7 1.7 16.8 6.5 287 14 298 165 -4.4 0 -4.4 -4.6 03/26/2007 12:20:00 14.9 1.4 19.1 11.5 14.9 1.4 19.1 11.8 11.5 1.6 17.2 8 289 15 292 165 -4.4 0 -4.4 -4.6 03/26/2007 12:30:00 15.5 1.7 19.1 11.5 15.5 1.7 19.5 11.8 12.1 1.8 17.6 8 286 16 281 165 -4.5 0 -4.4 -4.6 03/26/2007 12:40:00 15.9 1.6 20.2 11.1 15.9 1.7 20.6 11.1 12.2 1.8 18.7 8.4 286 15 284 165 -4.4 0 -4.4 -4.6 03/26/2007 12:50:00 15.3 1.5 19.9 8.4 15.5 1.6 20.6 7.6 11.5 1.6 16.1 7.6 288 14 291 165 -4.4 0 -4.2 -4.6 03/26/2007 13:00:00 13.9 1.9 18.3 8 14 1.9 18.3 8 10.7 1.9 16.4 6.8 292 14 292 165 -4.3 0 -4.2 -4.6 03/26/2007 13:10:00 12.4 1.5 16.8 8.4 12.5 1.5 17.2 8.8 10.3 1.7 15.3 6.1 298 15 297 165 -4.2 0.1 -3.9 -4.6 03/26/2007 13:20:00 9.5 1.8 13.7 5.3 9.6 1.8 13.7 5.3 7.7 1.5 13 4.6 293 16 312 165 -3.9 0.3 -3 -4.4 03/26/2007 13:30:00 9.4 1.5 13 5.7 9.5 1.5 13.3 6.1 7.9 1.5 12.6 4.2 293 16 284 165 -3.7 0.2 -3 -3.9 03/26/2007 13:40:00 10.1 1.7 14.9 5.7 10.2 1.7 15.3 5.7 8.2 1.5 12.6 5.3 292 15 297 165 -3.8 0 -3.5 -4.2 03/26/2007 13:50:00 12.1 1.3 15.6 8.8 12.1 1.4 15.6 8.8 10 1.8 18.3 6.1 295 14 305 165 -4.2 0.1 -3.9 -4.4 03/26/2007 14:00:00 11.9 1.8 15.6 7.6 11.9 1.9 15.6 7.6 10 1.6 14.9 6.5 290 16 277 165 -4.3 0 -4.2 -4.6 03/26/2007 14:10:00 10.7 1.7 15.3 7.2 10.7 1.7 15.6 7.2 9 1.4 12.6 5.7 290 15 296 165 -4.2 0 -4.2 -4.6 03/26/2007 14:20:00 14 2.5 18.7 8.4 14 2.5 19.1 8.4 11.1 1.7 16.4 7.2 294 15 302 165 -4.5 0.2 -4.2 -4.8 03/26/2007 14:30:00 15.1 1.5 19.1 10.7 15.1 1.5 19.5 11.1 12.2 1.7 16.8 8.4 293 15 281 165 -4.8 0 -4.6 -5 03/26/2007 14:40:00 14 1.4 16.8 9.9 13.9 1.4 17.2 9.5 11.6 1.7 16.4 8 291 16 279 165 -4.7 0 -4.4 -4.8 03/26/2007 14:50:00 13.8 1.8 18.7 8.4 13.7 1.9 18.7 8.8 11.2 1.7 17.6 7.2 296 16 312 165 -4.5 0.1 -4.2 -4.8 03/26/2007 15:00:00 14.3 1.8 18.7 10.7 14.2 1.8 18.7 10.3 11.6 1.7 17.6 6.8 293 16 305 165 -4.5 0 -4.4 -4.6 03/26/2007 15:10:00 13.4 1.8 17.6 8.4 13.2 1.9 17.6 8 11.3 1.5 14.9 5.7 299 14 274 165 -4.4 0 -4.2 -4.6 03/26/2007 15:20:00 12.1 1.5 15.6 8.4 12 1.5 16.1 8 10.8 1.7 16.1 6.8 301 15 300 165 -4.3 0 -4.2 -4.6 03/26/2007 15:30:00 12.6 1.8 17.6 7.6 12.5 1.9 17.9 7.6 10.6 1.7 14.9 5.7 295 16 295 165 -4.4 0 -4.2 -4.6 03/26/2007 15:40:00 12.6 1.8 17.6 8 12.4 1.8 17.2 8 11.5 1.8 17.6 6.8 305 12 303 165 -4.2 0.1 -3.9 -4.6 03/26/2007 15:50:00 13.2 1.7 16.8 9.1 13.2 1.7 17.2 9.1 10.9 1.5 14.5 7.2 300 13 294 165 -4.3 0 -4.2 -4.6 03/26/2007 16:00:00 12.7 1.6 16.4 8.4 12.6 1.6 16.1 8 11.6 1.7 16.1 7.6 307 10 311 165 -4.3 0 -4.2 -4.6 03/26/2007 16:10:00 12 2 16.1 7.2 12 2 16.1 7.6 9.6 1.7 14.1 5.3 299 12 297 165 -4.5 0 -4.4 -4.6 03/26/2007 16:20:00 11.5 1.3 14.9 7.6 11.5 1.3 14.9 7.6 8.8 1.3 13 6.1 289 13 286 165 -4.7 0.1 -4.4 -4.8 03/26/2007 16:30:00 9 1.7 13 4.9 9.2 1.7 13.3 5.7 8.1 1.7 12.6 4.2 282 12 277 165 -4.7 0 -4.6 -4.8 03/26/2007 16:40:00 9.3 1 11.8 6.5 9.7 0.8 11.8 7.6 9.5 1 11.8 6.8 275 6 281 165 -4.8 0 -4.6 -4.8 03/26/2007 16:50:00 10.2 1.3 13 6.8 10.3 1.2 13 6.8 8.6 1.5 12.2 5.3 286 11 276 165 -4.8 0 -4.6 -5 03/26/2007 17:00:00 11.9 1.2 14.9 8.8 11.8 1.2 15.3 8.4 9.8 1.5 13.3 6.5 300 11 298 165 -4.8 0 -4.6 -5 03/26/2007 17:10:00 11 1.3 14.9 7.2 11 1.3 14.1 7.2 8.8 1.3 12.6 5.7 289 15 291 165 -5 0 -4.6 -5.3 03/26/2007 17:20:00 11.1 1.7 15.3 7.2 11.3 1.7 15.6 7.2 10 2.2 14.9 4.9 281 11 278 165 -5.4 0 -5 -5.7 03/26/2007 17:30:00 11.4 1.2 14.5 8.4 11.5 1.2 14.1 8.4 11.3 1.4 14.1 6.8 278 6 276 165 -5.7 0 -5.5 -5.9 03/26/2007 17:40:00 9.9 1.1 12.6 6.8 10 1.1 12.2 6.1 9.1 1.5 12.2 5.3 283 10 263 165 -5.6 0 -5.5 -5.9 03/26/2007 17:50:00 12 0.8 13.7 9.9 12 0.9 13.7 9.9 9.2 1.2 12.6 6.5 293 11 277 165 -5.8 0 -5.7 -5.9 03/26/2007 18:00:00 11.7 1.1 14.5 8.8 11.7 1.1 14.1 8.4 9.1 1.2 14.5 6.1 294 13 298 165 -6 0 -5.7 -6.1 03/26/2007 18:10:00 11.5 0.8 13.3 9.5 11.5 0.8 13.3 9.5 8.4 1 11.8 6.5 291 11 277 165 -6.2 0 -6.1 -6.6 03/26/2007 18:20:00 12.2 0.7 14.5 10.7 12.2 0.7 14.9 10.3 8.7 1 11.5 6.8 293 12 286 165 -6.4 0 -6.1 -6.6 03/26/2007 18:30:00 13.3 0.9 15.3 10.7 13.4 0.9 15.6 10.7 9.5 1 12.6 6.5 292 10 302 165 -6.5 0 -6.4 -6.8 03/26/2007 18:40:00 11.7 0.8 13.7 9.5 11.7 0.8 13.7 9.9 8.8 1.2 13 6.5 290 10 290 165 -6.7 0 -6.6 -6.8 03/26/2007 18:50:00 10.4 0.7 11.8 7.6 10.5 0.7 12.2 8.4 8.8 1.3 11.8 5.3 286 10 289 165 -6.8 0 -6.6 -7 03/26/2007 19:00:00 11.9 0.4 13 10.7 12 0.4 13 10.7 10.8 0.9 12.6 7.6 288 6 289 165 -6.9 0 -6.8 -7 03/26/2007 19:10:00 12.2 0.8 14.1 9.9 12.2 0.9 14.1 9.9 8.7 0.8 11.1 6.5 292 10 301 165 -6.9 0 -6.8 -7.2 03/26/2007 19:20:00 11.6 0.8 13.7 9.1 11.6 0.8 13.3 9.1 8 0.8 10.7 6.5 295 10 308 165 -7.2 0.1 -6.8 -7.4 03/26/2007 19:30:00 10.7 0.8 13 8.8 10.7 0.8 13 8.8 8.1 1.1 11.8 6.1 292 14 281 165 -7.5 0 -7.2 -7.6 03/26/2007 19:40:00 10.6 0.8 13 8 10.5 0.9 13 8 8.7 1.2 12.2 5.7 297 13 304 165 -7.6 0 -7.4 -7.6 03/26/2007 19:50:00 12.1 1 13.7 8.8 12.1 1 14.1 8.8 9.7 1.1 12.6 6.8 297 13 280 165 -7.6 0 -7.4 -8.1 03/26/2007 20:00:00 12.5 0.9 14.1 9.9 12.6 0.9 14.1 9.9 8.7 1 12.2 6.1 296 9 300 165 -7.8 0 -7.6 -8.1 03/26/2007 20:10:00 11.5 1 14.5 8.8 11.4 1 14.1 8.8 9.4 1.3 12.6 5.7 296 14 301 165 -7.9 0 -7.6 -8.1 03/26/2007 20:20:00 11.4 1.3 14.9 8.8 11.4 1.3 14.9 8.8 8.2 1.2 12.2 5.7 291 13 289 165 -8 0 -7.6 -8.1 03/26/2007 20:30:00 12.4 0.9 14.9 10.3 12.4 0.9 14.9 10.3 9 1 12.2 6.8 289 15 300 165 -7.8 0 -7.6 -8.1 03/26/2007 20:40:00 12.5 0.9 14.9 9.5 12.5 1 14.9 9.9 9.2 1.3 13 6.8 288 13 300 165 -7.8 0 -7.6 -8.1 03/26/2007 20:50:00 11.7 1.1 14.5 8.4 11.7 1.1 14.5 8.4 9.1 1 12.2 6.8 288 14 293 165 -7.5 0.1 -7.2 -8.1 03/26/2007 21:00:00 11.5 0.8 13.3 9.1 11.5 0.8 14.1 9.1 9.2 1.2 13 6.5 285 15 292 165 -7.5 0 -7.2 -7.6 03/26/2007 21:10:00 11.6 1.1 14.1 7.6 11.6 1.1 14.1 7.6 9.1 1.3 13 5.3 285 15 295 165 -7.4 0 -7.2 -7.6 03/26/2007 21:20:00 12 1 14.5 9.5 12 1 14.9 9.1 9.3 1.2 13 6.5 284 16 296 165 -7.3 0 -7.2 -7.6 03/26/2007 21:30:00 11.9 1.3 15.3 8.8 11.9 1.3 15.3 8.8 9.4 1.4 14.9 6.1 283 15 277 165 -7.5 0 -7.2 -7.6 03/26/2007 21:40:00 11.5 1.1 14.1 8.8 11.5 1 14.1 8.8 8.8 1.3 13 5.7 286 15 292 165 -7.5 0 -7.4 -7.6 03/26/2007 21:50:00 11.1 1.2 14.1 8 11.1 1.2 14.1 8 8.9 1.3 13.7 6.1 282 15 281 165 -7.6 0 -7.4 -7.6 03/26/2007 22:00:00 11.8 1.2 14.5 9.1 11.8 1.2 14.5 9.1 9.6 1.3 13 6.5 282 15 281 165 -7.6 0 -7.4 -8.1 03/26/2007 22:10:00 12.2 1.1 14.5 8.4 12.3 1.1 14.5 8.4 9.1 1.1 12.6 6.1 285 15 286 165 -7.6 0 -7.4 -8.1 03/26/2007 22:20:00 12.1 1.1 14.5 8.4 12.2 1.1 14.9 8.8 10.3 1.5 13.3 6.5 284 12 291 165 -7.6 0 -7.4 -8.1 03/26/2007 22:30:00 12 1.1 15.6 8.4 12.1 1.1 15.6 8.8 9.6 1.3 13.3 6.1 285 13 295 165 -7.7 0 -7.6 -8.1 03/26/2007 22:40:00 11.5 1.1 14.1 8.4 11.6 1.1 14.1 8.4 9.5 1.5 13 6.1 284 13 293 165 -7.6 0 -7.4 -8.1 03/26/2007 22:50:00 11 1 14.1 8.8 11.1 1.1 14.1 8.8 10.1 1.3 13.7 6.5 281 13 289 165 -7.5 0.1 -7.4 -8.1 03/26/2007 23:00:00 11 1.1 13.7 7.6 11 1.1 13.7 7.6 9.6 1.3 13.3 6.1 280 16 262 165 -7.5 0 -7.4 -7.9 03/26/2007 23:10:00 11.2 1.1 14.5 8 11.2 1.1 14.5 7.6 10.1 1.2 13.3 7.2 280 14 287 165 -7.7 0 -7.6 -8.1 03/26/2007 23:20:00 12 1.2 14.5 8.4 12.1 1.2 14.5 8.4 11.4 1.3 14.1 7.6 282 12 289 165 -7.8 0 -7.6 -8.1 03/26/2007 23:30:00 12.1 1 14.5 8.8 12.1 1 14.9 9.1 10.9 1.5 14.5 7.6 281 14 272 165 -7.8 0 -7.6 -8.1 03/26/2007 23:40:00 10.5 1.1 14.5 7.2 10.5 1.1 14.9 7.2 9.2 1.3 12.6 5.7 282 15 273 165 -7.8 0 -7.4 -8.1 03/26/2007 23:50:00 10.9 1.3 14.5 8.4 10.9 1.3 14.5 8 8.4 1.1 12.6 5.3 284 18 282 165 -7.6 0 -7.4 -8.1 03/27/2007 00:00:00 11.3 1.3 13.7 7.2 11.3 1.3 14.1 7.6 8.9 1.7 14.5 6.1 284 17 294 165 -7.8 0 -7.6 -8.1 03/27/2007 00:10:00 11.4 1.1 14.1 8.8 11.5 1.1 14.1 8.8 10.8 1.4 14.1 7.2 279 15 282 165 -7.6 0 -7.4 -8.1 03/27/2007 00:20:00 12.2 1.3 15.3 8.4 12.2 1.3 15.6 8.4 11.1 1.5 14.9 6.8 279 14 273 165 -7.7 0 -7.4 -8.1 03/27/2007 00:30:00 12 1.4 15.3 8.4 12.1 1.4 15.3 8.4 10.9 1.7 14.9 6.8 282 13 251 165 -7.8 0 -7.6 -8.1 03/27/2007 00:40:00 12.2 1.1 14.9 9.5 12.2 1.1 14.9 9.1 11.3 1.7 15.6 6.8 279 13 296 165 -7.9 0 -7.6 -8.1 03/27/2007 00:50:00 12.5 1.6 16.1 7.6 12.5 1.6 16.1 7.6 9.6 1.5 13.3 6.1 283 17 300 165 -7.6 0.1 -7.2 -8.1 03/27/2007 01:00:00 12 1.3 15.3 8.8 12 1.3 15.3 8.4 9.3 1.2 13.3 6.8 287 18 293 165 -7.6 0 -7.4 -7.6 03/27/2007 01:10:00 12.4 1.7 16.1 8.4 12.4 1.7 16.1 8.4 9.8 1.6 15.3 5.7 290 18 300 165 -7.5 0 -7.2 -8.1 03/27/2007 01:20:00 11.9 1.4 14.9 8.4 11.9 1.3 14.9 8 9.5 1.3 13.7 6.5 284 18 295 165 -7.5 0 -7.4 -7.9 03/27/2007 01:30:00 12.4 1.4 17.2 8.4 12.4 1.4 17.2 8.8 9.7 1.4 14.5 6.8 287 17 301 165 -7.4 0.1 -7.2 -7.6 03/27/2007 01:40:00 13 1.7 17.2 8.8 12.9 1.6 16.8 8.4 10.4 1.5 15.6 6.8 291 17 287 165 -7.3 0 -7.2 -7.4 03/27/2007 01:50:00 12.9 1.7 17.6 9.1 12.9 1.6 17.6 8.4 10.6 1.6 14.9 6.5 287 16 288 165 -7.1 0 -6.8 -7.4 03/27/2007 02:00:00 13.6 1.7 17.9 9.9 13.5 1.7 17.6 9.9 10.5 1.7 15.3 7.2 288 16 302 165 -6.9 0 -6.6 -7.2 03/27/2007 02:10:00 14.9 1.6 19.9 11.1 14.8 1.5 19.5 11.1 11.8 1.8 16.8 8 285 17 297 165 -6.8 0.1 -6.6 -7.2 03/27/2007 02:20:00 16.3 2.2 21 9.9 16.2 2.2 21.4 9.9 12.7 1.7 18.3 8 287 17 290 165 -6.9 0 -6.6 -7.2 03/27/2007 02:30:00 17.8 2.3 24 12.2 17.8 2.3 24.4 12.2 13.6 2.1 21.8 9.5 285 17 289 165 -6.9 0 -6.8 -7.2 03/27/2007 02:40:00 18.3 1.9 22.1 13 18.3 1.8 22.1 12.6 14.6 2.2 21.8 9.1 285 15 272 165 -7 0.1 -6.6 -7.2 03/27/2007 02:50:00 17.8 1.7 22.9 12.6 17.6 1.7 22.6 12.6 14.3 1.9 22.1 9.9 292 15 303 165 -6.5 0.2 -5.9 -6.8 03/27/2007 03:00:00 15.9 1.4 20.2 11.8 15.7 1.3 19.5 11.5 13.9 1.7 19.1 9.5 301 15 300 165 -5.6 0.1 -5.3 -6.1 03/27/2007 03:10:00 15.1 1.3 18.7 11.5 14.8 1.3 17.9 10.7 13.6 1.5 17.6 9.1 304 13 282 165 -5.8 0.1 -5.5 -6.1 03/27/2007 03:20:00 15.2 1.8 21 11.1 15 1.8 20.2 10.7 14.1 1.8 19.5 9.5 311 15 319 165 -5.9 0 -5.5 -6.1 03/27/2007 03:30:00 16.8 2 22.1 11.5 16.6 1.9 21.8 11.5 14 2.3 21.8 8.8 295 16 314 165 -6.5 0.1 -6.1 -6.8 03/27/2007 03:40:00 16.5 1.9 23.7 10.7 16.3 1.9 22.9 10.3 14.8 1.8 21.8 9.9 302 17 308 165 -6.4 0.1 -6.1 -6.6 03/27/2007 03:50:00 19 2.3 25.2 13.7 18.8 2.2 25.6 13.7 18.5 2.5 24.8 12.6 322 15 348 165 -5.6 0.5 -4.8 -6.4 03/27/2007 04:00:00 18.8 1.9 24 14.1 18.6 1.9 24 13.7 17.7 1.9 22.9 13.3 307 13 278 165 -6 0.4 -5 -6.6 03/27/2007 04:10:00 19.4 1.7 24 15.3 19.3 1.7 24.4 14.9 18.5 1.7 24 13 305 12 308 165 -6.6 0 -6.1 -6.8 03/27/2007 04:20:00 20.7 1.7 25.6 15.6 20.5 1.7 26 16.1 20.1 1.9 25.2 14.9 307 12 297 165 -6.6 0.2 -6.1 -6.8 03/27/2007 04:30:00 22.7 1.7 26.8 16.8 22.7 1.7 26.3 16.4 21.7 1.9 25.6 15.6 303 12 306 165 -6.7 0 -6.6 -6.8 03/27/2007 04:40:00 23.9 2.4 30.9 18.3 23.8 2.4 30.6 18.3 22.8 2.7 31.3 16.1 303 15 284 165 -6.6 0.1 -6.1 -6.8 03/27/2007 04:50:00 23.9 2.2 30.2 15.6 23.8 2.2 29.8 16.1 23.5 2.3 29.8 17.9 310 13 292 165 -6.1 0.1 -5.7 -6.6 03/27/2007 05:00:00 23.1 2.4 31.3 17.9 23.1 2.5 30.6 17.6 21.9 2.8 29.1 16.1 304 15 318 165 -5.8 0.2 -5.5 -6.4 03/27/2007 05:10:00 23.1 2.4 32.4 16.8 23 2.4 32.9 17.6 22.1 2.6 33.2 16.1 302 14 300 165 -5.3 0.2 -4.8 -5.7 03/27/2007 05:20:00 23.4 2.2 30.9 15.6 23.4 2.2 30.6 14.9 22 2.6 30.6 14.9 300 13 306 165 -5.7 0.1 -5.3 -5.9 03/27/2007 05:30:00 22.8 2.1 29.4 17.2 22.7 2.1 29.4 16.4 21.7 2.3 28.7 16.1 301 14 297 165 -5.8 0.1 -5.5 -5.9 03/27/2007 05:40:00 22.7 2.3 31.3 16.1 22.7 2.4 31.3 16.1 21.9 2.6 30.6 15.3 302 14 314 165 -5.5 0.2 -5 -5.9 03/27/2007 05:50:00 23.5 2.5 31.3 17.6 23.5 2.5 30.6 17.2 22.4 2.7 31.3 16.4 300 16 301 165 -5.2 0.1 -4.8 -5.7 03/27/2007 06:00:00 22.2 2.7 30.6 15.3 22.1 2.7 30.2 14.9 21.1 2.7 29.8 13.7 303 15 302 165 -5 0.2 -4.6 -5.3 03/27/2007 06:10:00 21.3 2.3 26.3 15.3 21.2 2.3 26.3 15.3 20.1 2.6 26.8 13 304 13 319 165 -4.7 0.2 -4.4 -5 03/27/2007 06:20:00 20.7 2.7 27.5 13.7 20.6 2.7 26.8 13.7 19.7 2.9 26.8 12.6 305 19 299 165 -4.7 0.1 -4.4 -5 03/27/2007 06:30:00 18.5 2.5 25.2 10.7 18.4 2.5 24.8 9.9 17.1 2.9 25.6 8 305 17 321 165 -4.6 0.1 -4.4 -5 03/27/2007 06:40:00 16.3 2.6 22.6 11.1 16.1 2.6 22.6 10.3 15.4 2.6 21.8 9.9 315 19 325 165 -4.5 0.1 -3.9 -4.6 03/27/2007 06:50:00 14.6 2.2 22.6 9.1 14.5 2.2 22.9 9.5 13.9 1.9 19.1 9.5 316 17 304 165 -4.4 0.2 -3.9 -4.6 03/27/2007 07:00:00 17.8 2.2 26.3 13 17.6 2.2 25.6 13 16.7 2.4 24.4 11.8 309 19 300 165 -4.3 0.1 -3.9 -4.6 03/27/2007 07:10:00 19.5 2.4 27.5 11.8 19.4 2.4 27.1 11.8 19 2.7 27.1 12.2 312 17 322 165 -4 0.1 -3.7 -4.6 03/27/2007 07:20:00 18.8 2.2 24.4 11.5 18.7 2.3 24.4 10.3 17.8 2.3 27.1 12.6 312 14 306 165 -3.8 0.3 -3.3 -4.4 03/27/2007 07:30:00 19.5 2.4 26.3 13.3 19.4 2.6 26.3 13 18.7 2.7 27.9 11.8 318 17 322 165 -3.3 0.1 -3 -3.9 03/27/2007 07:40:00 19.7 2.2 25.2 14.1 19.5 2.2 25.6 13.7 19 2.5 25.2 13.3 317 16 314 165 -3.4 0.1 -3 -3.5 03/27/2007 07:50:00 17.4 1.8 26 13.3 17.3 1.9 25.2 13.3 17.1 2 24 12.2 322 13 338 165 -3.3 0.2 -3 -3.5 03/27/2007 08:00:00 17.3 1.9 23.3 11.5 17.2 1.9 22.9 11.5 16.9 2 22.9 12.6 318 14 319 165 -3.8 0 -3.5 -4.2 03/27/2007 08:10:00 16.8 1.8 21.4 11.8 16.7 1.8 21.8 12.2 16.2 1.9 21.4 11.1 315 17 250 165 -3.9 0 -3.7 -4.2 03/27/2007 08:20:00 17.2 2.3 24 11.8 17 2.3 24 11.8 16.2 2.4 22.1 10.7 311 16 310 165 -3.9 0 -3.7 -4.2 03/27/2007 08:30:00 16.8 2.1 23.7 11.8 16.7 2.1 23.3 10.7 16 2.2 24 10.7 317 15 307 165 -3.7 0.1 -3.3 -4.2 03/27/2007 08:40:00 14.9 1.9 19.5 9.5 14.8 1.8 19.1 9.9 14.3 1.8 18.7 8.8 321 13 331 165 -3 0.1 -2.6 -3.5 03/27/2007 08:50:00 17.9 2.5 23.3 10.3 17.8 2.5 23.3 10.3 17.1 2.8 23.3 10.3 317 15 322 165 -2.9 0 -2.8 -3 03/27/2007 09:00:00 18.6 1.7 24.4 13.3 18.5 1.7 25.6 13.3 18 2.1 25.2 12.2 311 13 285 165 -2.9 0.1 -2.8 -3 03/27/2007 09:10:00 18.8 1.8 22.9 14.1 18.7 1.8 22.9 14.1 17.8 1.9 22.9 11.8 308 13 306 165 -2.9 0.2 -2.6 -3.3 03/27/2007 09:20:00 19.3 1.5 24.4 15.3 19.2 1.5 24.4 14.9 17.8 2.5 24.8 11.5 306 13 310 165 -3.2 0.1 -2.8 -3.5 03/27/2007 09:30:00 18.1 2.2 24.4 12.2 18.1 2.1 24 11.8 16.6 2.3 23.3 10.3 303 15 296 165 -3.1 0.1 -2.8 -3.5 03/27/2007 09:40:00 15.9 1.7 21 10.7 15.8 1.7 21 10.7 14.1 2 19.9 9.9 304 15 297 165 -2.6 0.2 -2.1 -3 03/27/2007 09:50:00 16 1.9 20.6 11.1 15.9 1.8 20.6 11.5 15.2 2.1 21 10.3 312 17 312 165 -2 0.1 -1.7 -2.4 03/27/2007 10:00:00 15.5 1.9 20.2 10.7 15.4 1.9 20.2 10.3 14.9 2.1 20.6 10.7 316 15 309 165 -1.7 0.2 -1.4 -2.1 03/27/2007 10:10:00 17.7 1.9 22.9 12.2 17.6 1.8 22.6 13 16.7 2.3 23.3 12.2 309 15 302 165 -1.8 0.2 -1.4 -2.1 03/27/2007 10:20:00 19.1 2.4 27.1 13.3 19 2.4 26.8 13 18 2.8 25.2 11.8 308 14 275 165 -1.8 0 -1.4 -2.1 03/27/2007 10:30:00 20 2.5 25.2 11.1 19.9 2.4 25.2 11.8 18.6 2.9 26.8 10.7 305 15 325 165 -1.7 0 -1.4 -2.1 03/27/2007 10:40:00 20.9 2 26.8 14.9 20.8 2 26 14.9 20.3 2.4 27.1 14.5 312 12 315 165 -1.9 0.1 -1.4 -2.1 03/27/2007 10:50:00 20.4 2.1 26.3 14.5 20.4 2.1 26.8 14.9 19.8 2.5 26.3 11.8 313 13 322 165 -1.5 0.1 -1.2 -1.9 03/27/2007 11:00:00 20.9 2.2 26.3 14.5 20.7 2.2 26 14.1 19.8 2.5 26.3 11.8 309 11 298 165 -1.6 0.1 -1.2 -1.9 03/27/2007 11:10:00 20.1 2.2 27.9 14.5 20 2.2 27.5 14.5 19.2 2.4 27.9 14.5 311 14 323 165 -1.5 0 -1.2 -1.9 03/27/2007 11:20:00 19.9 2.6 26 11.8 19.9 2.6 26 12.6 18.9 2.8 25.6 11.8 310 14 313 165 -1.4 0.1 -1.2 -1.7 03/27/2007 11:30:00 19.4 2.4 28.7 10.3 19.3 2.4 29.1 10.3 18.4 2.6 26.3 11.1 308 13 307 165 -1.4 0 -1.2 -1.7 03/27/2007 11:40:00 20.2 1.9 25.6 14.1 20.2 1.9 25.6 13.3 19.5 2.6 26.8 12.6 311 13 310 165 -1.2 0 -1 -1.4 03/27/2007 11:50:00 19.7 2.1 25.2 14.1 19.7 2.2 25.6 13.3 18 2.5 25.6 12.6 302 13 318 165 -1.4 0 -1.2 -1.7 03/27/2007 12:00:00 20.2 2.1 26.8 13.7 20.1 2.1 26.8 13.3 19.3 2.6 26.8 12.2 308 13 271 165 -1.4 0 -1.2 -1.7 03/27/2007 12:10:00 18.9 2 24.8 15.3 18.8 2 24 14.5 18.5 2.3 24.8 10.7 317 13 321 165 -1.2 0 -1 -1.4 03/27/2007 12:20:00 17.7 2.2 24.8 13 17.4 2.3 25.2 12.6 17.3 2.3 23.7 11.5 325 14 357 165 -0.8 0 -0.5 -1.2 03/27/2007 12:30:00 17.8 1.9 22.9 12.6 17.6 1.9 22.6 11.5 17.5 2.1 23.3 11.1 323 13 325 165 -0.6 0.1 -0.3 -1 03/27/2007 12:40:00 18.3 2.2 24 13.7 18.2 2.3 24 10.7 18.2 2.3 23.7 13 330 11 338 165 -0.4 0.2 -0.1 -0.8 03/27/2007 12:50:00 18 2.3 24.4 11.8 17.8 2.5 26 11.1 17.7 2.6 24.8 11.1 324 15 338 165 -0.4 0 -0.1 -0.5 03/27/2007 13:00:00 20.1 2.6 27.1 13 19.6 2.8 26 11.5 20.1 2.8 26.8 13 337 11 350 165 -0.3 0.1 -0.1 -0.5 03/27/2007 13:10:00 20.8 2.6 26.3 13.7 20.6 2.9 27.1 13.3 20.8 2.8 27.9 13.7 338 10 348 165 -0.3 0 -0.1 -0.5 03/27/2007 13:20:00 19.9 2.3 28.7 14.5 19.6 2.5 29.4 12.2 19.8 2.4 27.1 12.6 335 11 353 165 -0.1 0 -0.1 -0.3 03/27/2007 13:30:00 20.5 2.6 27.1 12.6 19.8 3.1 27.9 11.5 20.6 2.7 27.9 12.2 338 11 347 165 -0.2 0 -0.1 -0.3 03/27/2007 13:40:00 17.1 2.3 22.9 11.8 16.8 2.3 23.3 9.9 17.1 2.4 23.3 11.8 333 13 323 165 -0.1 0 0.2 -0.3 03/27/2007 13:50:00 16.3 1.7 20.6 12.2 16.2 1.6 20.2 11.8 15.8 1.7 20.6 11.5 322 12 312 165 -0.1 0 0.2 -0.3 03/27/2007 14:00:00 17.8 1.8 23.7 11.8 17.6 1.8 22.9 11.8 16.9 2.1 21 10.3 315 9 309 165 0 0.2 0.2 -0.3 03/27/2007 14:10:00 20.1 1.5 23.3 16.1 19.9 1.5 23.3 15.6 19.7 1.6 24 14.9 313 6 315 165 -0.5 0 -0.3 -0.8 03/27/2007 14:20:00 19.5 1.1 22.9 16.8 19.3 1.1 22.9 16.4 19.3 1.2 22.6 14.1 316 7 311 165 -0.3 0.1 -0.1 -0.5 03/27/2007 14:30:00 18.3 1.3 22.6 13.7 18 1.3 21.8 13.3 17.6 1.5 21.8 12.2 316 7 315 165 -0.1 0 0.2 -0.5 03/27/2007 14:40:00 17.8 1.6 22.1 13.3 17.5 1.6 21.8 12.6 17.1 1.7 21.8 12.2 317 7 319 165 -0.1 0 0.2 -0.3 03/27/2007 14:50:00 17.6 1.7 22.1 12.2 17.3 1.6 22.1 12.2 16.5 2 21 11.1 313 9 315 165 0.1 0 0.4 -0.1 03/27/2007 15:00:00 18.6 1.6 23.3 14.9 18.3 1.5 22.6 14.1 17.5 1.5 22.1 12.6 311 8 317 165 -0.1 0 0.2 -0.3 03/27/2007 15:10:00 20.2 1.4 25.2 16.1 20.1 1.3 24.4 16.1 19.3 1.4 22.9 15.3 311 6 305 165 -0.1 0 -0.1 -0.3 03/27/2007 15:20:00 20.8 1.3 23.7 16.4 20.6 1.2 23.7 16.4 20.3 1.3 24.4 16.8 313 6 319 165 -0.1 0 -0.1 -0.3 03/27/2007 15:30:00 20.3 1.3 23.3 16.4 20.1 1.3 23.3 16.1 19.7 1.5 22.6 14.9 314 7 312 165 -0.1 0.1 0.2 -0.3 03/27/2007 15:40:00 20.8 1.3 24.4 17.6 20.5 1.3 23.7 17.2 20.4 1.5 24 16.1 316 5 307 165 0.1 0 0.2 -0.1 03/27/2007 15:50:00 20.5 1.2 24.8 17.6 20.3 1.3 24.4 16.8 20.2 1.3 23.7 15.6 317 5 314 165 0.1 0 0.2 -0.1 03/27/2007 16:00:00 19.5 1.1 22.1 15.3 19.2 1.1 22.6 14.9 19 1.4 22.6 14.1 318 6 323 165 0.1 0 0.2 -0.1 03/27/2007 16:10:00 19.2 1.6 22.6 13.7 19 1.5 22.6 14.1 18.9 1.6 22.9 14.9 321 9 309 165 0 0.1 0.2 -0.3 03/27/2007 16:20:00 18.2 1.3 21.8 14.9 17.9 1.2 22.1 14.5 17.6 1.3 22.1 12.6 317 6 315 165 0.1 0 0.2 -0.1 03/27/2007 16:30:00 17.7 1.6 23.3 14.1 17.4 1.9 24 9.9 17.3 2 24 11.5 323 12 348 165 0.2 0 0.2 -0.1 03/27/2007 16:40:00 17.3 1.8 23.7 11.8 17 1.9 22.9 12.6 16.4 2.1 21.8 11.8 326 16 310 165 0.1 0.1 0.2 -0.1 03/27/2007 16:50:00 16.6 2.2 21.8 11.5 16.1 2.5 21.4 8.8 16.1 2.4 22.1 11.1 332 15 336 165 0.2 0 0.4 -0.1 03/27/2007 17:00:00 16.4 1.9 22.9 12.2 16.1 2 22.1 9.9 15.8 2.1 22.6 10.7 338 12 359 165 0.2 0 0.7 0.2 03/27/2007 17:10:00 14.7 1.7 19.5 10.3 14.4 1.9 19.1 8.4 13.7 1.7 18.7 9.9 341 8 342 165 0.4 0 0.7 0.2 03/27/2007 17:20:00 14.8 1.6 19.1 10.3 14.4 1.9 19.1 9.5 14.2 1.8 19.1 9.5 338 13 343 165 0.2 0 0.7 -0.1 03/27/2007 17:30:00 14.3 1.5 18.3 10.3 14.1 1.6 18.7 9.9 13.4 1.6 16.8 9.5 332 13 340 165 0.1 0 0.2 -0.1 03/27/2007 17:40:00 15.5 1.5 20.2 11.5 15.3 1.5 19.9 9.9 14.7 1.6 18.7 10.7 330 12 335 165 0.1 0 0.2 -0.1 03/27/2007 17:50:00 17.7 2.2 23.3 13 17.6 2.3 22.9 13 16.9 2.3 22.9 11.8 336 12 351 165 -0.3 0.1 -0.1 -0.5 03/27/2007 18:00:00 14.5 2.4 20.6 8 14.3 2.4 19.9 8.4 13 2.5 19.5 7.6 328 13 323 165 -0.2 0 -0.1 -0.5 03/27/2007 18:10:00 15.7 2.1 22.1 8.8 15.3 2.3 23.3 9.1 14.9 2.4 21.8 8.4 341 10 345 165 -0.6 0 -0.3 -0.8 03/27/2007 18:20:00 17.5 1.8 22.6 13.3 16.8 2 21.8 11.1 16.9 1.8 23.7 12.2 342 10 350 165 -0.8 0.1 -0.5 -1.2 03/27/2007 18:30:00 15.7 2.6 21.8 9.1 15.2 2.6 22.6 9.5 15 2.5 20.2 8.4 338 13 344 165 -1.1 0 -1 -1.4 03/27/2007 18:40:00 16 2.2 21.8 9.9 15.3 2.3 20.6 9.1 15.2 2.3 20.2 9.5 338 14 354 165 -1.3 0.1 -1.2 -1.4 03/27/2007 18:50:00 13.6 1.9 17.9 8.4 13.5 1.8 17.9 8.8 12.1 2.1 17.2 6.8 322 13 327 165 -1.5 0 -1.2 -1.9 03/27/2007 19:00:00 11.9 2 17.2 6.8 11.8 2.1 17.2 6.5 10.7 1.9 16.8 6.1 323 16 323 165 -1.6 0 -1.4 -1.9 03/27/2007 19:10:00 13.6 1.9 18.3 8.4 13.3 2 18.3 8.4 12.5 2.2 17.9 7.2 338 11 336 165 -1.7 0 -1.4 -1.9 03/27/2007 19:20:00 13.8 2.8 21.8 7.6 13.4 2.8 21.4 7.6 12.7 2.9 19.9 6.8 335 14 344 165 -2.1 0 -1.7 -2.4 03/27/2007 19:30:00 15.7 2.2 20.6 11.1 15.5 2.2 19.9 10.3 14.4 2.4 19.9 8.8 331 12 351 165 -2.4 0 -2.1 -2.6 03/27/2007 19:40:00 17.2 1.8 22.1 11.5 16.8 2 22.1 11.5 16.5 2 20.6 11.5 338 10 325 165 -2.4 0 -2.1 -2.6 03/27/2007 19:50:00 16.4 2.1 21.8 10.3 16 2.3 22.6 9.9 15.6 2.3 21.4 6.5 339 9 344 165 -2.3 0 -2.1 -2.6 03/27/2007 20:00:00 16.5 2.6 21.8 10.7 16.1 2.6 22.6 10.3 16.1 2.7 22.6 10.3 338 11 337 165 -2.2 0 -2.1 -2.6 03/27/2007 20:10:00 17.1 2.5 24.4 10.7 16.8 2.7 25.2 9.9 16.8 2.6 24 10.3 336 11 340 165 -2.2 0 -1.9 -2.6 03/27/2007 20:20:00 15.9 2.5 24 10.3 15.7 2.6 24.8 10.3 15.3 2.6 22.1 9.5 338 12 344 165 -2.4 0.1 -2.1 -2.6 03/27/2007 20:30:00 13.4 2.3 19.5 8.4 13.1 2.3 19.1 8 12.9 2.3 19.9 8.4 328 15 355 165 -2.5 0 -2.1 -2.8 03/27/2007 20:40:00 12.9 1.7 17.6 7.6 12.8 1.7 18.3 7.6 11.9 1.7 18.3 7.6 312 14 338 165 -2.9 0.2 -2.6 -3.3 03/27/2007 20:50:00 13.8 2 17.9 8.4 13.6 1.9 17.9 8.4 12.1 1.9 16.8 6.5 310 17 341 165 -3 0.1 -2.8 -3.3 03/27/2007 21:00:00 11.7 1.9 16.8 6.5 11.5 1.9 16.8 6.5 10.9 2 15.6 6.5 317 15 307 165 -3 0 -2.6 -3.5 03/27/2007 21:10:00 12.9 2.5 18.3 8 12.7 2.5 18.3 6.8 12 2.8 18.3 6.5 316 15 332 165 -2.4 0.3 -1.9 -3 03/27/2007 21:20:00 13.4 2 17.6 8.4 13.3 2 17.2 8.8 11.2 2.1 18.3 6.5 301 13 295 165 -3.1 0 -2.8 -3.3 03/27/2007 21:30:00 14.8 1.9 18.7 10.3 14.7 1.8 18.7 9.5 12 2 18.3 7.2 296 11 283 165 -3.3 0 -3 -3.5 03/27/2007 21:40:00 14 2 19.5 9.1 13.9 2 18.7 8.4 11.9 1.8 17.6 7.2 301 13 272 165 -3.3 0.1 -2.8 -3.5 03/27/2007 21:50:00 16.3 2.5 23.7 10.7 16.1 2.5 23.3 10.7 13.8 2.6 19.9 7.6 301 11 309 165 -3.4 0.1 -3 -3.5 03/27/2007 22:00:00 17.5 2.2 23.7 11.5 17.4 2.2 23.7 11.8 14.3 2.4 22.9 8.8 301 10 317 165 -3.2 0 -3 -3.5 03/27/2007 22:10:00 15.4 1.7 20.2 10.7 15.3 1.7 20.2 10.7 12.9 2.1 19.9 7.6 299 11 300 165 -3 0.2 -2.6 -3.5 03/27/2007 22:20:00 16.4 1.9 21.8 10.3 16.2 1.9 22.1 9.9 13.4 2.2 22.6 8.4 301 9 292 165 -3.4 0 -3.3 -3.5 03/27/2007 22:30:00 15.1 2.2 21.4 9.9 15 2.2 21 9.9 11.9 2.5 22.6 7.6 297 10 302 165 -3.5 0.1 -3.3 -3.5 03/27/2007 22:40:00 14.3 1.7 17.6 8.8 14.3 1.7 17.9 8.4 11.5 2.1 17.2 7.2 291 10 288 165 -3.4 0 -3.3 -3.7 03/27/2007 22:50:00 12.4 1.8 16.8 7.6 12.3 1.9 16.4 7.6 10.6 1.8 14.9 6.1 303 17 300 165 -3.2 0 -2.8 -3.5 03/27/2007 23:00:00 12 1.9 16.4 6.5 11.8 1.9 16.4 6.1 11.1 1.9 15.6 6.1 316 15 334 165 -2.8 0.2 -2.4 -3.3 03/27/2007 23:10:00 14.6 1.7 18.3 9.5 14.5 1.7 17.9 9.5 11.9 1.5 16.1 8 300 11 281 165 -3.1 0 -2.8 -3.3 03/27/2007 23:20:00 15.4 1.2 19.5 11.8 15.4 1.2 19.9 11.5 12.2 1.7 16.4 8.4 289 9 303 165 -3.4 0.2 -3 -3.5 03/27/2007 23:30:00 14.4 1.5 18.7 9.9 14.5 1.4 19.1 9.1 12.3 1.9 17.9 7.6 287 9 282 165 -3.6 0 -3.3 -3.7 03/27/2007 23:40:00 14.3 1.5 21.4 10.7 14.3 1.5 21 10.7 11.7 1.9 17.9 7.2 290 10 272 165 -3.5 0.1 -3.3 -3.7 03/27/2007 23:50:00 14.1 1.5 17.6 10.3 14.1 1.5 17.9 10.3 11 1.8 18.3 7.6 293 11 289 165 -3.5 0 -3.3 -3.5 03/28/2007 00:00:00 15.4 1.8 21.8 10.7 15.4 1.8 21.8 11.1 12.4 2 20.2 8 290 8 282 165 -3.4 0 -3.3 -3.7 03/28/2007 00:10:00 14.6 2.1 20.6 7.2 14.6 2 20.6 7.6 11.5 1.8 16.8 5.7 291 11 292 165 -3.4 0 -3.3 -3.5 03/28/2007 00:20:00 13.7 1.5 17.9 10.3 13.7 1.5 17.9 9.5 10.9 1.9 17.2 6.8 288 11 287 165 -3.4 0 -3 -3.5 03/28/2007 00:30:00 11.1 1.7 19.1 7.2 11 1.7 18.3 6.8 9.3 2.2 17.2 3.8 285 10 292 165 -2.9 0.3 -2.6 -3.5 03/28/2007 00:40:00 10.5 1.5 15.3 6.5 10.4 1.5 16.1 6.5 8.6 1.8 14.9 4.2 289 10 287 165 -3.2 0 -2.8 -3.5 03/28/2007 00:50:00 11.2 1.4 14.5 7.6 11.1 1.4 14.5 7.6 9.3 1.3 13 6.1 301 15 284 165 -2.9 0 -2.6 -3.3 03/28/2007 01:00:00 13.2 1.7 17.9 9.1 13.1 1.7 17.9 9.1 10.9 1.5 14.5 6.8 297 14 300 165 -3.3 0.1 -2.8 -3.5 03/28/2007 01:10:00 11.6 1.9 15.6 6.8 11.4 1.8 15.6 6.5 9.4 1.9 13.7 3.4 301 15 278 165 -3 0.1 -2.8 -3.3 03/28/2007 01:20:00 14.2 2.2 19.5 9.1 14.1 2.2 19.1 8.8 11.5 2.3 18.3 4.6 301 10 318 165 -3.1 0 -2.8 -3.3 03/28/2007 01:30:00 17.5 1.5 20.6 13.3 17.3 1.5 20.2 13.3 15.7 1.7 20.2 9.9 308 7 311 165 -3.3 0.2 -2.8 -3.5 03/28/2007 01:40:00 17.6 1 19.9 13.7 17.5 1.1 19.9 13.3 14.7 1.7 19.9 9.1 305 5 308 165 -3.6 0.1 -3.3 -3.9 03/28/2007 01:50:00 17.1 0.9 19.1 14.1 17 0.9 19.1 13.7 13.3 1.4 17.6 9.9 302 6 304 165 -3.7 0 -3.5 -3.9 03/28/2007 02:00:00 16.9 1.1 19.9 14.1 16.8 1.1 19.9 13.3 12.1 1.5 17.2 8.8 299 6 297 165 -3.7 0 -3.5 -3.9 03/28/2007 02:10:00 16.5 1.2 19.5 12.2 16.5 1.3 19.5 12.2 12.2 1.5 16.1 9.1 291 9 299 165 -3.6 0 -3.5 -3.9 03/28/2007 02:20:00 17 1.6 21 12.2 17 1.6 21 12.2 12.7 1.7 17.6 8 291 10 296 165 -3.5 0 -3.3 -3.7 03/28/2007 02:30:00 15.8 1.7 18.3 11.1 15.8 1.7 18.7 11.1 11.5 1.6 16.1 7.6 293 9 287 165 -3.7 0 -3.5 -3.9 03/28/2007 02:40:00 15.9 1.2 18.3 12.2 15.9 1.3 18.3 12.2 11.5 1.5 16.1 8.4 295 9 295 165 -3.7 0 -3.5 -3.9 03/28/2007 02:50:00 15 1.4 17.9 10.7 14.9 1.5 17.6 10.7 11.5 1.4 15.6 8.4 296 10 302 165 -3.8 0 -3.5 -4.2 03/28/2007 03:00:00 14.4 1.2 17.6 11.5 14.4 1.3 17.2 11.5 11.1 1.5 15.6 8.4 297 9 301 165 -3.8 0 -3.7 -4.2 03/28/2007 03:10:00 14 1.3 17.2 10.3 13.9 1.3 16.8 10.3 10.7 1.5 15.3 7.6 299 8 294 165 -4 0.1 -3.9 -4.4 03/28/2007 03:20:00 14 1.2 16.8 11.5 13.9 1.2 16.8 11.1 10.9 1.4 14.9 8 298 9 309 165 -4.2 0 -3.9 -4.4 03/28/2007 03:30:00 14.8 1.1 19.1 11.5 14.7 1.1 18.7 11.5 11.6 1.6 16.1 8.8 302 8 298 165 -4.1 0 -3.9 -4.4 03/28/2007 03:40:00 15.1 1.1 17.6 11.8 15.1 1.1 17.2 12.2 11.6 1.7 15.6 8 301 7 299 165 -4.1 0 -3.9 -4.4 03/28/2007 03:50:00 16.9 1.1 20.2 13.3 16.8 1.1 19.9 13.3 12.5 1.5 16.4 9.5 300 9 298 165 -4 0 -3.9 -4.4 03/28/2007 04:00:00 16.7 1.3 19.9 13 16.6 1.3 19.9 12.2 12.2 1.5 17.9 8.4 299 9 307 165 -4.1 0 -3.9 -4.4 03/28/2007 04:10:00 14.9 1.7 19.5 11.1 14.8 1.7 19.5 10.7 11.2 1.5 16.1 7.6 296 9 298 165 -4.1 0 -3.9 -4.4 03/28/2007 04:20:00 13.5 2 18.7 8 13.4 2 18.7 7.6 11.2 1.8 16.1 6.5 298 12 287 165 -3.7 0.2 -3.3 -4.4 03/28/2007 04:30:00 14.1 1.5 17.9 9.5 14 1.5 17.9 9.1 11.1 1.8 17.2 6.8 294 10 303 165 -3.2 0 -2.8 -3.5 03/28/2007 04:40:00 15.2 1.4 18.3 11.5 15.1 1.4 18.3 11.1 11.9 1.7 16.4 8 298 11 295 165 -3.5 0.1 -3.3 -3.9 03/28/2007 04:50:00 14.7 1.5 19.1 11.5 14.5 1.5 18.7 11.1 11.4 1.7 16.4 8 300 11 302 165 -3.8 0 -3.5 -3.9 03/28/2007 05:00:00 14 1.6 17.6 9.9 13.9 1.7 17.6 9.1 10.1 1.4 14.9 6.1 297 9 307 165 -3.8 0 -3.5 -4.4 03/28/2007 05:10:00 13.1 1.3 16.1 9.9 13 1.3 16.1 9.5 9.7 1.4 13.3 6.1 295 10 298 165 -3.9 0 -3.7 -4.2 03/28/2007 05:20:00 14.6 1.5 18.3 10.3 14.5 1.5 18.3 10.3 10.8 1.5 16.8 7.2 294 10 291 165 -3.7 0.1 -3.5 -4.2 03/28/2007 05:30:00 14.5 1.6 18.7 10.3 14.5 1.6 18.3 10.3 10.8 1.3 14.9 7.2 297 10 298 165 -3.5 0 -3.3 -3.7 03/28/2007 05:40:00 13.9 1.3 16.8 9.9 13.9 1.3 16.8 10.3 10.9 1.7 16.4 6.5 290 9 292 165 -3.6 0 -3.5 -3.9 03/28/2007 05:50:00 14.2 1.7 18.3 9.5 14.1 1.8 18.3 9.9 11.2 2 16.8 7.6 291 9 277 165 -3.6 0 -3.3 -3.9 03/28/2007 06:00:00 14.4 1.5 19.5 10.3 14.4 1.5 19.9 9.9 12.1 2.1 19.1 7.2 286 10 282 165 -3.6 0 -3.5 -3.9 03/28/2007 06:10:00 15.3 1.9 22.6 9.9 15.3 1.9 21.8 10.3 12.1 2.3 17.9 7.6 290 11 283 165 -3.5 0.1 -3 -3.9 03/28/2007 06:20:00 14.9 2 20.6 10.3 14.8 2 20.6 10.3 11.7 1.8 17.2 7.6 292 11 293 165 -3.7 0 -3.5 -3.9 03/28/2007 06:30:00 15.5 1.9 21.4 11.1 15.4 1.9 21.4 11.1 12 2.1 19.9 7.6 291 12 282 165 -3.9 0 -3.5 -4.2 03/28/2007 06:40:00 14.5 1.7 18.7 10.3 14.4 1.7 18.3 10.3 11.6 2 17.9 7.2 287 12 286 165 -3.8 0 -3.5 -4.2 03/28/2007 06:50:00 13.5 1.5 17.6 9.1 13.5 1.5 17.2 9.9 11.1 2.2 17.2 6.5 285 12 271 165 -3.7 0 -3.5 -3.9 03/28/2007 07:00:00 11.6 1.6 15.6 8 11.6 1.6 15.6 8 9.9 2 15.6 5.7 285 11 288 165 -3.5 0 -3.3 -3.9 03/28/2007 07:10:00 10 1.5 14.1 6.5 9.8 1.4 13.3 6.5 8.2 1.3 13 5.3 291 13 278 165 -3.2 0 -3 -3.5 03/28/2007 07:20:00 12.3 1.8 16.8 8 12.2 1.7 16.4 6.8 9.8 2.1 16.1 4.2 288 13 303 165 -3.4 0 -3.3 -3.5 03/28/2007 07:30:00 11.8 1.8 15.6 5.7 11.6 1.8 15.3 5.7 9.2 1.6 13.7 4.6 293 15 295 165 -3.2 0 -3 -3.5 03/28/2007 07:40:00 11.6 1.4 16.1 8 11.5 1.4 16.4 7.2 9.3 1.3 13 5.7 294 13 229 165 -3.2 0.1 -2.8 -3.5 03/28/2007 07:50:00 12.2 1.7 17.6 6.5 12.1 1.7 17.6 6.5 9.7 1.9 17.9 5.7 294 12 301 165 -3 0 -2.8 -3.3 03/28/2007 08:00:00 12.1 1.4 15.6 8.4 12.1 1.4 15.6 8.8 10.7 2 16.4 6.5 286 9 286 165 -3.2 0 -2.8 -3.5 03/28/2007 08:10:00 11.3 1.7 15.3 4.9 11.3 1.7 14.9 4.9 9.8 1.9 14.1 4.6 286 11 281 165 -3.2 0 -2.8 -3.5 03/28/2007 08:20:00 10.2 1.4 13.7 7.2 10.2 1.4 13.7 6.8 9.1 1.5 13.3 4.6 285 12 287 165 -3 0 -2.8 -3.5 03/28/2007 08:30:00 10.1 1.2 12.6 6.5 10 1.2 12.6 6.8 8.4 1.2 11.8 4.9 294 14 296 165 -2.8 0.2 -2.6 -3 03/28/2007 08:40:00 9.4 1.5 13 4.9 9.2 1.5 12.6 5.7 8.5 1.4 12.2 5.3 311 16 315 165 -2.5 0 -2.4 -2.8 03/28/2007 08:50:00 10.1 1.7 13.7 5.3 9.9 1.7 13.3 5.3 8.5 1.4 11.8 4.9 302 15 285 165 -2.5 0 -2.1 -2.8 03/28/2007 09:00:00 11.9 1.7 17.6 7.6 11.8 1.6 17.6 7.6 10.1 1.7 15.6 6.8 299 15 290 165 -2.8 0 -2.6 -3 03/28/2007 09:10:00 11.2 1.7 16.1 7.6 11 1.7 16.4 7.6 9.5 1.7 14.5 4.9 303 15 302 165 -2.5 0.1 -2.4 -3 03/28/2007 09:20:00 9.4 1.3 13.3 6.5 9.2 1.3 13.3 6.5 8.4 1.5 12.6 5.7 311 14 306 165 -2.1 0.2 -1.7 -2.6 03/28/2007 09:30:00 9.8 1.5 13.7 5.7 9.7 1.5 13.7 5.7 9.5 1.7 13.7 4.2 321 15 333 165 -1.9 0.1 -1.7 -2.1 03/28/2007 09:40:00 10.5 1.8 16.4 6.5 10.5 1.8 16.8 6.5 9.5 1.8 14.1 5.7 303 19 309 165 -2 0.2 -1.7 -2.6 03/28/2007 09:50:00 10.6 1.3 14.5 6.8 10.4 1.2 15.3 6.8 9.2 1.2 13.7 5.3 307 13 306 165 -2 0.1 -1.7 -2.6 03/28/2007 10:00:00 10.5 1.5 14.1 6.8 10.3 1.5 14.1 6.5 9.7 1.4 13.7 6.1 318 15 304 165 -1.4 0.2 -1 -2.1 03/28/2007 10:10:00 11.3 1.9 16.8 8 11.1 1.9 16.8 7.6 10.5 2 16.1 6.5 318 15 334 165 -1.3 0.1 -1.2 -1.9 03/28/2007 10:20:00 11.3 2.3 17.2 4.6 11 2.1 17.6 4.6 10.5 2.4 17.9 4.2 317 20 360 165 -1.4 0 -1.2 -1.7 03/28/2007 10:30:00 12.1 1.8 16.1 8.4 12 1.8 15.6 8.4 11.1 1.7 15.6 6.8 314 16 285 165 -1.4 0 -1.2 -1.7 03/28/2007 10:40:00 12.9 1.4 17.2 9.5 12.7 1.4 17.2 9.9 11.3 1.9 17.2 7.2 307 10 307 165 -1.6 0.1 -1.4 -1.9 03/28/2007 10:50:00 11.9 2 17.2 6.1 11.8 2 17.2 6.5 10.6 1.9 15.6 5.7 307 12 302 165 -1.3 0 -1 -1.7 03/28/2007 11:00:00 13.5 1.8 18.7 9.5 13.3 1.8 18.7 9.9 10.6 1.8 17.2 6.5 298 10 302 165 -1.4 0.1 -1.2 -1.9 03/28/2007 11:10:00 15.1 1.7 18.3 9.1 15 1.7 18.7 9.1 11.5 1.8 16.8 7.2 299 9 304 165 -1.7 0 -1.4 -2.1 03/28/2007 11:20:00 12.8 2 18.7 5.3 12.6 1.9 17.9 6.5 10 1.7 15.6 4.2 298 11 315 165 -1 0.3 -0.3 -1.7 03/28/2007 11:30:00 11.2 1.6 15.6 6.5 11.1 1.6 14.9 6.8 8.9 1.6 16.4 4.2 298 10 258 165 -0.5 0.2 0.2 -1 03/28/2007 11:40:00 13 1.8 17.2 6.8 12.8 1.8 17.2 7.2 10.5 1.7 14.9 6.1 300 10 295 165 -0.9 0.2 -0.5 -1.7 03/28/2007 11:50:00 12 1.8 16.8 8.4 11.9 1.8 16.4 8 10.1 2 16.1 6.5 306 12 322 165 -0.8 0.1 -0.3 -1.2 03/28/2007 12:00:00 12.3 1.8 17.2 8.8 12.2 1.7 17.2 8.4 10.2 1.9 16.8 6.5 304 11 314 165 -0.6 0 -0.3 -1 03/28/2007 12:10:00 13 1.7 17.9 8.8 12.8 1.6 17.9 8.8 10.6 1.9 16.8 6.5 303 11 300 165 -0.5 0 -0.3 -0.8 03/28/2007 12:20:00 12.8 1.7 17.6 8 12.7 1.6 17.2 7.2 11 1.7 16.1 6.5 307 10 297 165 -0.4 0 -0.3 -0.8 03/28/2007 12:30:00 11.5 1.5 15.3 7.2 11.4 1.5 15.3 6.5 9.6 1.7 15.6 5.3 303 10 295 165 -0.3 0.1 -0.1 -0.8 03/28/2007 12:40:00 12.6 2.1 19.1 5.3 12.6 2 19.5 5.3 10.7 2.1 17.6 4.2 296 12 302 165 -0.3 0.2 -0.1 -0.8 03/28/2007 12:50:00 14.5 1.2 17.6 10.3 14.5 1.2 17.6 10.3 11.4 1.5 14.9 8.4 302 7 304 165 -0.8 0 -0.5 -1.2 03/28/2007 13:00:00 14.5 1.5 20.6 11.1 14.4 1.5 20.6 11.1 12.7 1.7 21 9.5 308 8 310 165 -0.6 0.1 -0.3 -1 03/28/2007 13:10:00 14.5 1.3 17.6 11.1 14.4 1.3 17.6 11.1 12.9 1.7 16.8 8.4 309 9 306 165 -0.5 0.2 -0.3 -1.2 03/28/2007 13:20:00 12.6 1.4 17.6 8.8 12.4 1.4 17.6 9.1 11.2 1.5 15.3 6.5 311 8 298 165 -0.1 0.2 0.7 -1 03/28/2007 13:30:00 12.2 1.7 16.1 6.8 12 1.7 16.1 6.5 11 1.6 15.3 6.8 313 12 302 165 0.2 0.2 0.7 -0.3 03/28/2007 13:40:00 12.8 1.9 17.6 7.6 12.6 1.9 17.9 7.6 11.4 1.8 16.4 4.9 312 9 301 165 -0.1 0.2 0.2 -0.8 03/28/2007 13:50:00 12.2 2.1 16.8 7.2 12.2 2.1 16.4 7.2 10.8 1.9 16.1 6.1 308 10 301 165 0 0.2 0.7 -0.8 03/28/2007 14:00:00 13.6 1.7 18.3 9.5 13.4 1.7 18.7 9.1 12.5 1.4 16.1 8 311 11 285 165 -0.1 0.2 0.2 -0.5 03/28/2007 14:10:00 13.6 1.6 17.6 9.5 13.4 1.7 17.6 9.5 11.8 1.6 16.1 7.2 308 9 307 165 -0.1 0.1 0.2 -0.8 03/28/2007 14:20:00 13.4 1.2 16.8 10.3 13.4 1.2 16.4 9.9 11.2 1.3 14.5 7.6 306 8 295 165 -0.2 0.1 0.2 -0.8 03/28/2007 14:30:00 12.7 1.3 16.1 9.1 12.6 1.3 16.1 8.8 11.1 1.5 16.1 7.2 308 8 317 165 -0.2 0 -0.1 -0.8 03/28/2007 14:40:00 13 1.5 17.6 9.5 12.8 1.5 17.6 9.1 11 1.6 15.6 6.5 305 10 301 165 -0.3 0.1 -0.1 -0.8 03/28/2007 14:50:00 10.1 2.3 15.3 5.7 10.1 2.2 14.9 5.7 8.4 1.8 14.5 4.9 305 14 297 165 0.4 0.4 0.9 -0.5 03/28/2007 15:00:00 12.1 2.3 17.2 5.3 11.9 2.3 16.4 4.9 10.2 2 14.9 4.9 305 12 295 165 0.2 0.2 0.9 -0.5 03/28/2007 15:10:00 11.7 2.4 17.2 5.7 11.5 2.4 17.6 4.6 10 2.6 16.1 3.8 309 13 307 165 0.5 0 0.9 -0.1 03/28/2007 15:20:00 13.3 1.5 17.6 9.5 13.2 1.5 17.2 9.1 11.3 1.7 16.8 6.8 306 11 313 165 0.7 0.1 0.9 0.2 03/28/2007 15:30:00 14.1 2.4 19.9 7.2 13.9 2.3 19.5 7.6 11.7 2.2 16.4 5.7 301 9 296 165 0.3 0.2 0.9 -0.3 03/28/2007 15:40:00 16.7 1.6 21 12.6 16.6 1.5 20.6 12.2 12.8 1.6 17.6 8.8 299 8 297 165 -0.2 0.2 0.4 -0.8 03/28/2007 15:50:00 16.9 1.7 21.4 11.8 16.7 1.6 20.6 11.5 13 1.5 16.8 9.5 298 12 297 165 -0.4 0.2 -0.1 -1 03/28/2007 16:00:00 18.1 2 22.6 13.3 18 2 22.9 13 14.3 1.9 19.1 9.9 299 11 302 165 -0.4 0.1 -0.1 -1.2 03/28/2007 16:10:00 18.9 1.5 22.1 13 18.9 1.5 21.8 13 14.5 1.7 18.7 9.1 298 10 300 165 -0.5 0 -0.3 -1 03/28/2007 16:20:00 17.4 1.9 21.4 10.7 17.3 2 21.4 10.7 13.7 1.7 18.7 9.9 296 11 293 165 -0.4 0.1 -0.3 -1 03/28/2007 16:30:00 17.9 1.5 22.1 12.2 17.9 1.5 22.6 12.2 12.4 1.5 19.1 8.4 294 9 299 165 -0.5 0.1 -0.3 -1.2 03/28/2007 16:40:00 17.5 1.5 21 14.1 17.5 1.5 21.4 14.1 12.8 1.7 18.3 9.1 297 10 300 165 -0.5 0 -0.3 -0.8 03/28/2007 16:50:00 17.8 1.2 20.6 13.7 17.7 1.3 20.2 13.7 14.2 1.7 18.7 10.3 301 9 310 165 -0.4 0 -0.3 -0.5 03/28/2007 17:00:00 19.3 1.3 21.8 14.9 19.2 1.3 22.1 14.5 16.2 1.7 20.6 11.8 302 9 293 165 -0.3 0 -0.3 -0.5 03/28/2007 17:10:00 19.3 1.2 22.1 15.3 19.2 1.3 22.1 14.9 17.2 1.5 20.6 12.6 304 9 304 165 -0.4 0 -0.3 -0.8 03/28/2007 17:20:00 18.6 1.5 21.4 14.5 18.5 1.5 21.4 13.7 17.3 1.5 21.8 13 308 10 307 165 -0.3 0 -0.3 -0.8 03/28/2007 17:30:00 17.6 1.5 21 13.7 17.4 1.5 20.6 13.3 15.6 1.7 19.1 10.3 304 11 315 165 -0.4 0 -0.3 -0.5 03/28/2007 17:40:00 17.6 1.2 21 13.3 17.5 1.2 20.6 13.3 12.6 1.5 18.3 9.1 298 8 308 165 -0.5 0 -0.3 -0.8 03/28/2007 17:50:00 17.1 1.4 19.9 11.5 17 1.5 19.9 11.1 12.7 1.6 18.3 9.5 296 11 294 165 -0.5 0 -0.3 -0.8 03/28/2007 18:00:00 15.7 1.6 19.9 11.8 15.7 1.6 19.9 11.8 12.1 1.5 16.8 9.1 298 11 298 165 -0.4 0 -0.3 -0.8 03/28/2007 18:10:00 15.8 1.1 18.7 12.2 15.7 1.1 18.7 12.6 14 1.7 17.9 9.1 305 6 308 165 -0.5 0 -0.3 -0.8 03/28/2007 18:20:00 15.6 1.3 18.3 12.2 15.4 1.2 17.9 11.8 14.9 1.4 18.7 11.1 310 7 309 165 -0.5 0 -0.3 -0.8 03/28/2007 18:30:00 15.6 1.3 18.7 11.8 15.4 1.3 18.7 11.5 13.9 2 17.9 9.1 307 8 301 165 -0.6 0 -0.5 -0.8 03/28/2007 18:40:00 14.1 1.2 17.2 10.3 14 1.3 17.2 9.9 11.9 1.4 15.6 8.8 305 7 305 165 -0.8 0 -0.5 -1 03/28/2007 18:50:00 14.3 1.4 16.8 10.3 14.3 1.4 16.8 10.3 11.4 1.4 15.6 7.6 302 6 304 165 -0.9 0 -0.8 -1 03/28/2007 19:00:00 13.6 1.3 17.2 9.1 13.5 1.4 17.2 8.8 11 1.6 14.9 7.2 301 8 298 165 -0.9 0 -0.8 -1.2 03/28/2007 19:10:00 14.4 1.6 17.9 9.9 14.2 1.6 17.9 9.5 12 1.4 16.4 8.8 304 9 302 165 -1.2 0 -0.8 -1.4 03/28/2007 19:20:00 13.4 1.5 16.4 9.5 13.3 1.5 16.4 9.1 11 1.3 14.9 7.6 304 10 297 165 -1.3 0 -1.2 -1.4 03/28/2007 19:30:00 14.9 1.7 19.1 10.3 14.8 1.7 19.1 10.3 11.5 1.4 16.1 8.4 300 8 301 165 -1.6 0 -1.4 -1.7 03/28/2007 19:40:00 13.9 1.6 17.9 9.1 13.8 1.6 17.9 8.8 10.7 1.5 14.5 6.5 298 10 302 165 -1.5 0 -1.2 -1.9 03/28/2007 19:50:00 12.5 1.8 17.6 7.2 12.4 1.8 17.2 7.2 9.8 1.7 16.8 5.7 294 10 281 165 -1.4 0 -1.2 -1.7 03/28/2007 20:00:00 11.9 1.8 15.6 5.3 11.8 1.8 15.6 5.7 9.3 1.4 12.6 5.7 297 12 293 165 -1.6 0 -1.4 -1.9 03/28/2007 20:10:00 11.8 1.9 15.3 6.8 11.7 1.9 15.3 6.8 9.6 1.4 13.7 6.5 300 13 294 165 -1.6 0 -1.4 -1.9 03/28/2007 20:20:00 10.2 2 14.1 3.4 10.1 2 14.1 3.4 8.7 1.7 12.2 3 303 13 301 165 -1.6 0 -1.4 -1.9 03/28/2007 20:30:00 10.4 1.5 13.7 7.2 10.3 1.5 13.3 6.8 8.7 1.3 13.3 5.3 301 15 281 165 -1.7 0 -1.4 -1.9 03/28/2007 20:40:00 12.2 1.6 16.4 8 12.1 1.5 15.6 8 9.7 1.4 12.6 6.1 300 10 289 165 -1.8 0 -1.7 -2.1 03/28/2007 20:50:00 11.7 1.3 14.9 8 11.6 1.3 14.5 8 8.8 1.1 12.2 6.5 299 8 302 165 -1.8 0.1 -1.4 -2.1 03/28/2007 21:00:00 12.3 1.2 14.9 8.8 12.2 1.2 14.5 8.8 10.5 1.3 13.3 7.2 305 8 310 165 -1.8 0 -1.4 -2.1 03/28/2007 21:10:00 12.9 1.5 16.8 9.1 12.8 1.6 16.8 9.1 10.9 1.6 15.6 6.5 302 9 307 165 -1.8 0 -1.7 -2.1 03/28/2007 21:20:00 11.1 1.9 15.6 6.8 10.9 1.9 15.3 6.8 9.6 1.7 14.5 5.3 306 8 308 165 -1.8 0.1 -1.4 -2.1 03/28/2007 21:30:00 10.5 1.5 13.7 6.8 10.3 1.4 13.3 6.8 8.7 1.3 12.2 5.7 305 8 302 165 -1.8 0 -1.7 -1.9 03/28/2007 21:40:00 11.8 1.3 14.9 8.4 11.8 1.4 14.9 8.8 9 1.3 12.2 6.5 300 8 301 165 -2.1 0 -1.7 -2.4 03/28/2007 21:50:00 13.1 1.1 16.1 10.3 13 1.2 16.1 10.3 10.7 1.3 13.7 7.2 305 6 302 165 -2 0.1 -1.7 -2.6 03/28/2007 22:00:00 11.9 1.3 14.9 7.2 11.8 1.3 14.9 6.8 9.2 1.3 12.6 6.1 305 6 301 165 -2.1 0 -1.9 -2.1 03/28/2007 22:10:00 11.9 1 14.1 8.8 11.9 1 14.1 9.1 8.5 0.8 11.1 6.1 300 5 298 165 -2.1 0 -1.9 -2.4 03/28/2007 22:20:00 10.9 1.1 13 8 10.8 1.1 13 8 8.5 1.1 11.5 6.1 302 6 300 165 -2.2 0 -2.1 -2.6 03/28/2007 22:30:00 11.2 0.8 13 8.8 11 0.8 12.6 8.8 9.6 1.2 12.6 7.2 309 5 318 165 -2.4 0 -2.1 -2.6 03/28/2007 22:40:00 11.7 1.1 13.7 8.4 11.6 1.1 13.7 8 9.7 1 12.6 7.2 308 5 307 165 -2.4 0 -2.1 -2.6 03/28/2007 22:50:00 10.6 1.5 14.1 6.8 10.4 1.4 13.3 6.8 8.6 1.3 12.6 5.7 305 7 309 165 -2.2 0 -1.9 -2.6 03/28/2007 23:00:00 9.2 2.3 13.7 4.6 9.1 2.2 13.7 4.2 7.8 2.1 12.2 2.3 307 9 301 165 -2 0 -1.9 -2.1 03/28/2007 23:10:00 7.3 1.3 10.3 4.6 7.2 1.3 10.3 4.6 5.8 1.1 9.5 3.4 299 10 306 165 -2.2 0 -2.1 -2.6 03/28/2007 23:20:00 7.3 1 9.9 4.6 7.2 1 9.9 4.9 6 1 8.8 3.8 300 11 296 165 -2.1 0 -1.9 -2.6 03/28/2007 23:30:00 9.1 1.3 12.2 5.3 9.1 1.3 12.2 5.3 7.2 1.1 9.9 4.2 303 6 302 165 -2 0.1 -1.7 -2.4 03/28/2007 23:40:00 9.2 1.1 11.8 5.7 9.2 1 11.8 6.1 7.5 1.1 10.7 4.9 298 8 300 165 -1.6 0 -1.4 -1.9 03/28/2007 23:50:00 8.4 1 10.7 5.3 8.4 1 11.1 5.7 7.2 1.5 11.1 3.8 293 8 298 165 -1.6 0 -1.4 -1.9 03/29/2007 00:00:00 9.3 1.2 13 5.7 9.3 1.2 13 6.1 7.4 1.3 11.1 4.6 298 7 283 165 -1.6 0 -1.4 -1.9 03/29/2007 00:10:00 10.6 1.1 13.7 7.6 10.6 1.1 13.3 7.2 8.4 1.3 11.8 5.7 295 5 297 165 -1.9 0 -1.7 -2.1 03/29/2007 00:20:00 10.2 1.2 13.3 6.5 10.2 1.2 13.3 6.5 9.4 1.4 12.6 5.7 287 9 289 165 -1.8 0 -1.4 -1.9 03/29/2007 00:30:00 11.2 1.2 14.1 8 11.3 1.2 14.1 8 9.2 1.7 13.3 6.1 293 7 307 165 -1.7 0 -1.4 -2.1 03/29/2007 00:40:00 11.6 1.2 15.6 8.4 11.6 1.2 15.6 8.4 9.3 1.5 13.3 6.5 295 6 288 165 -1.7 0.1 -1.4 -2.1 03/29/2007 00:50:00 11.7 1.2 13.7 7.6 11.7 1.2 13.7 7.6 8.7 1.4 12.6 5.7 295 5 295 165 -2 0 -1.9 -2.1 03/29/2007 01:00:00 11 1 13.3 8.8 11.1 1 13.3 9.1 9.2 1.3 12.6 5.7 292 6 295 165 -2 0 -1.9 -2.1 03/29/2007 01:10:00 10.4 1.3 14.5 8 10.4 1.2 14.5 8 8 1.4 12.2 5.3 298 7 302 165 -1.8 0 -1.7 -2.4 03/29/2007 01:20:00 10.8 1.1 13.7 7.6 10.8 1.1 13.7 7.6 9.3 1.5 13.3 6.1 291 5 282 165 -2.2 0 -1.9 -2.4 03/29/2007 01:30:00 10.9 1.3 13.7 8 10.9 1.3 14.1 7.6 8.8 1.5 12.6 5.3 293 6 292 165 -2 0.1 -1.7 -2.6 03/29/2007 01:40:00 11.2 1.1 13.7 7.2 11.2 1.1 13.3 7.2 8.3 1.3 12.2 5.7 293 7 285 165 -1.8 0 -1.7 -1.9 03/29/2007 01:50:00 11 1.1 13.3 8 10.9 1.1 13.3 8.4 8.7 1.1 11.5 6.1 304 6 301 165 -1.8 0.1 -1.4 -1.9 03/29/2007 02:00:00 11 1 13.3 8 10.8 1 13.3 8 9.1 1.2 11.8 6.1 306 6 305 165 -2 0 -1.9 -2.1 03/29/2007 02:10:00 10.8 1 13 7.2 10.8 1 12.6 6.8 7.6 0.8 10.3 5.7 299 5 298 165 -1.7 0 -1.7 -2.1 03/29/2007 02:20:00 11.6 1.2 14.1 7.6 11.5 1.1 13.7 8 9.6 1.3 13.7 6.8 306 5 308 165 -1.8 0 -1.7 -2.1 03/29/2007 02:30:00 10.8 0.8 12.6 8.4 10.6 0.9 12.6 8.4 8.8 1 11.1 5.7 307 7 308 165 -1.8 0 -1.7 -2.1 03/29/2007 02:40:00 7.7 1.2 10.7 4.6 7.5 1.1 10.3 4.6 6.6 1.3 9.9 3 308 8 311 165 -1.9 0.1 -1.7 -2.1 03/29/2007 02:50:00 5.3 0.8 7.6 3.4 5.1 0.9 7.6 2.3 4.8 0.6 6.8 3 320 17 303 165 -2 0.1 -1.4 -2.1 03/29/2007 03:00:00 4.9 0.9 6.8 2.6 4.7 0.9 6.8 2.6 4.7 0.9 6.8 2.6 321 11 314 165 -1.7 0 -1.4 -1.9 03/29/2007 03:10:00 4.3 1 7.6 1.9 4.1 1.1 7.2 1.5 4 0.9 6.5 1.9 320 17 340 165 -2.2 0.2 -1.9 -2.6 03/29/2007 03:20:00 3.6 0.9 6.8 1.9 3.4 0.9 6.1 1.5 3.3 0.7 5.3 1.1 321 17 310 165 -2.8 0.2 -2.4 -3 03/29/2007 03:30:00 4 0.8 6.1 1.5 3.8 0.9 5.7 1.1 3.5 0.8 5.3 1.5 316 22 305 165 -2.9 0.1 -2.6 -3.3 03/29/2007 03:40:00 6.2 1.5 9.5 2.3 6.1 1.6 9.1 1.9 5 1 7.6 3 307 18 300 165 -2.8 0.1 -2.4 -3 03/29/2007 03:50:00 6.4 1.1 9.1 2.6 6.3 1.2 9.1 2.6 5.1 0.9 7.6 2.3 304 12 291 165 -2.6 0.1 -2.1 -2.8 03/29/2007 04:00:00 8.2 1.1 10.3 3.8 8 1.1 9.9 4.2 6.3 1.1 9.9 3.4 300 8 304 165 -2.4 0 -2.1 -2.6 03/29/2007 04:10:00 8.4 0.8 10.7 6.5 8.3 0.8 10.3 6.1 6.4 0.9 9.1 4.6 302 6 299 165 -2.2 0 -1.9 -2.6 03/29/2007 04:20:00 10.3 0.8 12.2 7.2 10.2 0.9 11.8 6.8 7.7 1 10.7 5.3 305 5 310 165 -2.3 0.1 -2.1 -2.6 03/29/2007 04:30:00 10.3 0.7 12.2 8.4 10.2 0.7 12.2 8 8.9 0.8 10.7 6.8 309 4 302 165 -2.4 0 -2.1 -2.6 03/29/2007 04:40:00 10.8 0.7 12.6 8.8 10.7 0.7 12.6 8.8 8.7 1.1 11.1 6.1 307 4 308 165 -2.4 0 -2.1 -2.6 03/29/2007 04:50:00 10.6 0.8 13 8.4 10.4 0.8 12.6 8.4 9.2 1 12.2 6.8 310 5 310 165 -2.5 0 -2.6 -2.8 03/29/2007 05:00:00 10.2 0.9 12.6 6.8 10.1 0.9 12.2 6.8 9.1 1.2 11.5 5.7 311 8 311 165 -2.5 0 -2.4 -2.8 03/29/2007 05:10:00 8 1.3 11.5 4.9 7.9 1.3 11.1 4.9 7.5 1.5 11.1 3.4 318 13 314 165 -2 0.3 -1.7 -2.8 03/29/2007 05:20:00 8.4 1.5 11.1 4.9 8.2 1.5 11.1 4.2 7 1.1 9.5 3.8 311 8 307 165 -2.2 0.3 -1.7 -2.6 03/29/2007 05:30:00 10 1 13.3 7.6 9.8 0.9 12.6 7.2 7.8 0.9 10.7 5.7 306 5 303 165 -2.6 0 -2.4 -2.8 03/29/2007 05:40:00 9.2 1 11.5 6.5 9 0.9 11.1 6.1 7.6 1.1 10.7 4.9 308 6 314 165 -2.6 0 -2.6 -2.8 03/29/2007 05:50:00 9.8 0.9 12.2 6.5 9.7 0.9 12.2 6.5 7.9 1 10.3 5.3 306 6 301 165 -2.4 0.3 -1.9 -3 03/29/2007 06:00:00 10.5 0.8 12.2 8.4 10.4 0.8 12.2 8 8.2 0.9 10.7 6.1 304 6 300 165 -2.2 0 -2.1 -2.6 03/29/2007 06:10:00 10.2 1 12.2 7.6 10.1 1 12.2 7.6 7.7 0.8 10.3 5.3 303 6 300 165 -2.3 0 -2.1 -2.6 03/29/2007 06:20:00 10.7 0.7 13 9.1 10.6 0.7 12.6 8.4 7.8 0.9 10.3 6.1 303 4 304 165 -2.4 0.1 -2.1 -2.6 03/29/2007 06:30:00 11 1.1 13.3 8 10.9 1 13 8 8.7 1.3 11.8 5.7 305 6 305 165 -2.2 0.1 -1.9 -2.6 03/29/2007 06:40:00 8.8 1 10.7 6.1 8.7 1 10.7 5.7 7 1 9.1 4.2 305 7 304 165 -2.1 0.1 -1.9 -2.6 03/29/2007 06:50:00 5.5 1.4 9.5 2.3 5.3 1.5 9.5 1.5 4.9 1.2 8.4 2.6 319 16 312 165 -2 0 -1.7 -2.4 03/29/2007 07:00:00 5.1 0.9 6.8 2.6 4.9 0.9 6.8 2.6 4.5 0.8 6.5 2.3 311 15 309 165 -2 0.1 -1.7 -2.4 03/29/2007 07:10:00 4.6 1.3 8 1.9 4.4 1.3 7.6 1.5 4 0.9 6.1 1.5 313 16 293 165 -1.8 0 -1.7 -2.1 03/29/2007 07:20:00 3.8 1 6.1 1.5 3.6 1.1 6.1 1.1 3.2 1 6.1 0.7 306 21 291 165 -1.4 0.1 -1.2 -1.9 03/29/2007 07:30:00 3.1 1.1 6.1 0.4 2.8 1.3 6.5 0.4 2.7 1.1 5.3 0.4 315 16 313 165 -1.1 0 -0.8 -1.4 03/29/2007 07:40:00 5.5 2.4 11.1 1.1 5.4 2.4 10.7 0.4 4.3 1.8 9.9 0.7 302 17 289 165 -0.9 0.1 -0.8 -1.2 03/29/2007 07:50:00 9.7 1.3 13.3 6.1 9.5 1.3 13 5.7 7.8 1.5 13 4.6 295 6 290 165 -1.1 0 -0.8 -1.2 03/29/2007 08:00:00 10.1 1.3 13.3 6.8 10 1.3 13 6.8 7.6 1.3 11.5 4.6 298 6 291 165 -1.2 0 -1.2 -1.4 03/29/2007 08:10:00 9.9 1.3 13 6.1 9.8 1.2 12.6 5.7 7.5 1.2 11.1 5.3 298 6 296 165 -1.1 0 -0.8 -1.4 03/29/2007 08:20:00 10.3 1.3 13.7 7.2 10.3 1.3 13.3 7.2 7.7 1.3 11.1 4.9 297 6 313 165 -1.1 0 -0.8 -1.4 03/29/2007 08:30:00 10.9 0.8 13 8.4 10.9 0.8 13 8.4 7.7 1 10.3 5.7 298 5 305 165 -1 0 -0.8 -1.4 03/29/2007 08:40:00 9.5 0.9 12.6 7.6 9.5 0.9 12.6 7.6 6.9 1 10.3 4.9 299 6 300 165 -0.9 0.1 -0.5 -1.4 03/29/2007 08:50:00 9.2 0.8 11.8 7.2 9.2 0.8 11.5 6.8 7 0.8 9.5 4.9 299 6 301 165 -0.7 0 -0.5 -1 03/29/2007 09:00:00 9.5 1.2 12.2 6.8 9.4 1.2 12.6 6.5 7.4 1.2 10.7 5.3 303 7 289 165 -0.6 0.1 -0.3 -0.8 03/29/2007 09:10:00 9.7 1 13 6.8 9.6 1 13 6.8 7.8 1 11.1 5.7 306 6 302 165 -0.5 0 -0.3 -0.8 03/29/2007 09:20:00 9.9 1.6 14.1 6.8 9.9 1.7 14.9 6.5 7.5 1.4 12.2 4.6 300 6 296 165 -0.5 0 -0.1 -0.8 03/29/2007 09:30:00 11.9 1.2 15.6 8.4 11.8 1.2 15.3 8 9.6 1.2 13 6.8 305 7 300 165 -0.6 0 -0.3 -0.8 03/29/2007 09:40:00 12.1 1.5 16.1 8.8 12 1.5 16.1 8.8 9.9 1.3 13.3 6.8 306 6 304 165 -0.5 0 -0.3 -0.8 03/29/2007 09:50:00 11.8 1.5 14.9 7.2 11.8 1.6 14.9 7.2 9.3 1.1 12.2 6.8 305 6 298 165 -0.3 0 -0.1 -0.8 03/29/2007 10:00:00 11.6 1.3 15.3 7.2 11.5 1.3 14.5 7.2 8.9 1.1 12.2 5.7 299 7 297 165 -0.3 0 -0.1 -0.5 03/29/2007 10:10:00 11.7 1.5 15.3 7.6 11.6 1.5 16.4 8 9 1.7 14.1 6.1 298 6 293 165 -0.2 0 0.2 -0.5 03/29/2007 10:20:00 9.9 1.5 13.7 4.9 9.8 1.5 13.7 4.2 7.6 1.2 12.2 5.3 300 8 301 165 0.1 0.2 0.4 -0.5 03/29/2007 10:30:00 9.6 1.6 14.1 6.1 9.6 1.6 14.5 5.7 7.7 1.3 11.8 5.3 301 8 299 165 0.2 0.1 0.4 -0.3 03/29/2007 10:40:00 11 0.9 14.1 8.4 10.9 0.9 14.1 8.4 8.5 1 11.1 6.1 301 6 299 165 0.2 0.1 0.7 -0.3 03/29/2007 10:50:00 11.5 1.2 14.5 8 11.4 1.2 14.5 8 8.7 1.3 12.2 5.7 300 7 300 165 0.2 0.1 0.7 -0.3 03/29/2007 11:00:00 11.5 1.1 14.1 8.4 11.4 1.1 14.5 8.4 9.5 1.1 12.2 6.1 306 7 305 165 0.5 0.2 0.9 -0.3 03/29/2007 11:10:00 11.4 1.2 13.7 8 11.2 1.2 13.7 7.6 8.8 1.1 12.2 5.7 303 7 302 165 0.7 0.2 0.9 0.2 03/29/2007 11:20:00 10.1 1.5 14.1 5.3 10 1.5 13.7 5.3 7.9 1.3 12.2 4.6 299 9 306 165 0.7 0.1 0.9 0.4 03/29/2007 11:30:00 10 1.3 13 6.8 10.1 1.3 13.3 6.8 9.3 1.7 13.3 5.3 288 7 285 165 0.7 0 0.9 0.7 03/29/2007 11:40:00 10.3 1.3 14.9 7.2 10.3 1.3 14.1 6.8 8.4 1.5 12.6 4.9 297 8 288 165 0.9 0.1 1.4 0.7 03/29/2007 11:50:00 10.8 1.7 14.1 7.2 10.7 1.7 14.1 6.8 8.9 1.5 12.2 6.1 300 9 296 165 0.9 0.1 1.4 0.7 03/29/2007 12:00:00 10 1.5 13.3 6.5 10 1.5 13.3 6.5 7.7 1.4 11.8 4.9 298 7 288 165 0.9 0 1.4 0.7 03/29/2007 12:10:00 9.6 1 12.6 6.5 9.6 1 12.6 6.5 7.5 1.2 11.1 5.3 295 6 287 165 1.2 0 1.6 0.7 03/29/2007 12:20:00 9.5 1.4 12.2 5.3 9.5 1.4 12.2 4.9 7.4 1.3 11.5 3.8 297 9 298 165 1.2 0.2 1.6 0.7 03/29/2007 12:30:00 8.9 1.3 11.8 5.7 8.8 1.4 11.8 5.7 7.3 1.3 10.7 3.8 297 9 294 165 1.5 0.1 1.8 0.9 03/29/2007 12:40:00 8.7 1.3 11.1 4.9 8.8 1.3 11.1 4.9 7.3 1.3 10.7 4.2 292 8 298 165 1.4 0.1 1.8 1.4 03/29/2007 12:50:00 9 1.3 12.6 5.3 9 1.3 12.6 5.3 7.3 1.2 12.2 4.2 296 9 277 165 1.6 0 1.8 1.1 03/29/2007 13:00:00 9.9 1.1 13 6.5 9.9 1.2 13.3 6.1 7.9 1.5 12.2 5.3 297 7 288 165 1.6 0 1.8 1.4 03/29/2007 13:10:00 10 1.1 13 7.2 9.9 1.1 13 7.2 8.3 1 11.8 5.7 306 8 294 165 1.9 0.1 2.3 1.6 03/29/2007 13:20:00 9.9 1 12.6 7.6 9.8 1 12.6 7.6 8.1 1.3 12.6 5.3 304 6 300 165 2 0 2.3 1.8 03/29/2007 13:30:00 10.5 1.1 13 7.6 10.4 1.1 13.3 7.2 9.4 0.9 13 6.8 310 6 312 165 2.1 0.1 2.3 1.8 03/29/2007 13:40:00 10.6 0.8 13 8.4 10.4 0.8 12.6 8.4 9.5 1 12.2 6.8 310 4 309 165 2.1 0 2.6 1.8 03/29/2007 13:50:00 10.2 0.9 12.6 8 10.1 0.9 11.8 7.6 8.4 1 10.7 5.3 306 6 304 165 2.3 0.1 2.6 1.8 03/29/2007 14:00:00 10.4 1 13.7 7.6 10.2 1 13.7 7.6 9.2 1.2 13.7 6.5 310 7 311 165 2.4 0.1 2.8 1.8 03/29/2007 14:10:00 11.4 1.2 14.5 9.1 11.2 1.2 14.5 8.8 9.6 1.1 13.3 6.5 307 6 301 165 2.3 0 2.6 2.1 03/29/2007 14:20:00 11.1 1.3 14.5 6.8 11.1 1.3 14.5 7.2 9 1.6 13.7 5.3 305 8 302 165 2.3 0 2.6 1.8 03/29/2007 14:30:00 9.8 1.4 12.6 5.3 9.7 1.4 12.6 5.3 7.9 1.4 11.1 4.6 296 8 280 165 2.1 0 2.3 1.4 03/29/2007 14:40:00 8.2 1.7 13 3.4 8.1 1.7 12.6 2.6 7 1.7 11.8 2.6 295 13 294 165 2.4 0.2 3 1.8 03/29/2007 14:50:00 9.3 1.7 13.7 5.7 9.3 1.7 13.7 5.7 7.4 1.3 10.3 4.2 298 7 304 165 2.5 0.2 3 2.1 03/29/2007 15:00:00 10.7 1.1 13.3 7.2 10.7 1.1 13.3 7.2 8.3 1.1 11.8 5.3 303 5 299 165 2.4 0.1 2.8 1.8 03/29/2007 15:10:00 10.8 1.1 13.7 8.4 10.7 1.1 13.7 8.4 8.6 1.3 12.6 6.1 303 6 296 165 2.4 0 2.8 2.3 03/29/2007 15:20:00 12.1 1 14.1 9.5 11.9 1 13.7 9.1 10.3 1.5 14.1 6.8 309 6 315 165 2.4 0.1 2.8 2.1 03/29/2007 15:30:00 11.2 0.9 13.3 8.8 11.1 0.9 13.3 8.8 10 1.3 12.6 6.5 310 7 307 165 2.6 0 2.8 2.3 03/29/2007 15:40:00 10 1.3 13.7 5.3 10 1.3 13.7 6.1 8.7 1.2 11.8 6.1 308 9 305 165 2.7 0 3 2.3 03/29/2007 15:50:00 11 1.2 14.1 7.2 10.8 1.2 14.1 7.2 9.9 1.5 13.3 6.5 312 6 311 165 2.6 0 2.8 2.1 03/29/2007 16:00:00 12.3 1 14.5 9.1 12.1 1 14.5 9.1 11.8 1.2 14.5 8 315 6 316 165 2.7 0 2.8 2.3 03/29/2007 16:10:00 13.8 0.9 16.1 11.5 13.6 0.9 16.1 11.1 12.7 1.2 16.1 9.1 312 5 312 165 2.4 0 2.8 2.3 03/29/2007 16:20:00 13.8 1.2 16.4 11.1 13.6 1.2 16.4 10.7 12.9 1.3 16.1 9.1 313 5 314 165 2.3 0.1 2.6 1.8 03/29/2007 16:30:00 12.8 0.9 14.9 10.3 12.7 0.9 14.9 9.9 11.7 1.1 14.1 8.8 311 5 310 165 2.3 0.1 2.6 1.8 03/29/2007 16:40:00 12.7 1.3 15.3 8.4 12.5 1.3 15.3 8.4 10.8 1.5 14.5 7.2 308 7 316 165 2 0.2 2.6 1.4 03/29/2007 16:50:00 10.2 1.3 14.1 6.5 10.1 1.3 13.7 6.5 8 1.1 11.8 5.3 299 7 307 165 1.8 0.2 2.3 1.4 03/29/2007 17:00:00 11.6 1.3 14.9 8.4 11.6 1.3 14.9 8 9.4 1.5 14.1 5.7 300 7 293 165 1.8 0.2 2.3 1.1 03/29/2007 17:10:00 13.6 1.2 17.9 10.3 13.5 1.3 17.9 10.3 10.6 1.5 15.3 7.6 304 5 310 165 1.8 0.1 2.1 1.4 03/29/2007 17:20:00 12.4 1.1 15.3 9.5 12.3 1.1 15.3 9.5 10.5 1.6 14.5 7.2 307 6 304 165 1.8 0.1 2.1 1.4 03/29/2007 17:30:00 12 1.7 14.9 6.8 12 1.8 14.9 6.8 9.5 1.7 14.1 5.3 304 7 295 165 1.8 0.1 2.1 1.4 03/29/2007 17:40:00 10.3 2.2 14.5 4.9 10.2 2.2 14.1 4.6 8.1 1.8 13.7 3.8 301 9 291 165 1.8 0 2.3 1.4 03/29/2007 17:50:00 10 2 15.3 5.7 9.9 2 15.3 5.3 8.1 1.8 14.5 4.6 300 10 286 165 1.8 0 2.1 1.6 03/29/2007 18:00:00 9.7 1.9 13.7 5.7 9.7 1.8 13.3 5.7 7.5 1.5 11.1 3.8 300 9 301 165 1.7 0 1.8 1.6 03/29/2007 18:10:00 9.5 1.9 14.9 5.3 9.4 2 15.3 5.3 8 1.6 13.7 4.9 303 12 292 165 2 0.2 2.6 1.6 03/29/2007 18:20:00 8.7 1.8 13 3.8 8.7 1.8 12.6 4.2 6.8 1.7 12.6 2.3 301 13 316 165 2 0.2 2.6 1.8 03/29/2007 18:30:00 10.5 1.6 14.5 6.1 10.4 1.5 14.1 5.7 8.5 1.5 12.6 4.6 305 8 301 165 2 0.1 2.3 1.8 03/29/2007 18:40:00 10.3 2.2 15.3 5.3 10.1 2.2 14.9 4.9 7.8 2.1 12.6 2.6 301 12 302 165 1.5 0 1.8 1.4 03/29/2007 18:50:00 9.4 2.5 14.5 3.4 9.3 2.5 14.9 2.6 7.1 2.5 12.6 2.3 296 17 309 165 1.4 0.1 1.6 1.4 03/29/2007 19:00:00 3.4 2.2 8.8 0.4 3.1 2.1 8.8 0.4 2.7 1.8 9.1 0.4 322 90 247 165 1.4 0 1.6 1.1 03/29/2007 19:10:00 6 1.7 9.9 1.5 5.9 1.8 9.9 1.1 4.4 1.7 9.5 0.7 300 24 298 165 1.2 0.2 1.6 0.7 03/29/2007 19:20:00 6.8 1.9 11.1 1.5 6.9 1.8 11.1 2.3 4.8 1.9 10.3 0.7 293 19 301 165 0.4 0.1 0.9 0.2 03/29/2007 19:30:00 10 1.9 14.1 4.6 9.9 1.9 14.1 4.9 7.7 1.7 11.5 2.3 294 10 295 165 0.2 0.1 0.7 -0.1 03/29/2007 19:40:00 12.2 1.2 14.9 8.8 12.1 1.2 14.5 8.8 9.7 1.4 14.1 6.8 303 7 309 165 0.4 0 0.7 0.2 03/29/2007 19:50:00 13.9 1.2 16.4 11.1 13.8 1.2 16.8 11.1 11.5 1.3 15.6 8 305 7 304 165 0.4 0 0.7 0.2 03/29/2007 20:00:00 12.8 1.1 16.1 9.5 12.7 1.2 15.6 9.5 10.7 1.3 14.5 7.6 306 8 309 165 0.4 0 0.7 0.2 03/29/2007 20:10:00 12.3 1.1 14.9 9.5 12.3 1.1 14.5 9.9 9.6 1.3 14.1 6.8 301 8 302 165 0.4 0 0.7 0.2 03/29/2007 20:20:00 10.7 1.3 13.3 6.8 10.5 1.3 13 7.2 8.7 1.5 12.2 5.3 304 9 306 165 0.2 0 0.4 -0.1 03/29/2007 20:30:00 12.3 1.1 15.6 9.1 12.2 1.1 14.9 8.8 9.3 1.3 13 6.1 299 7 291 165 0.3 0 0.7 0.2 03/29/2007 20:40:00 11.7 1.6 15.3 7.6 11.6 1.6 15.3 8 9 1.5 14.1 5.7 298 7 300 165 0.2 0 0.4 0.2 03/29/2007 20:50:00 10.3 1.1 14.1 7.6 10.2 1 13.7 7.6 8.2 1.2 11.5 5.3 300 9 306 165 0.1 0 0.2 -0.3 03/29/2007 21:00:00 10.4 1.5 14.5 6.8 10.3 1.5 14.1 6.8 8.4 1.4 12.6 4.2 302 10 296 165 0.3 0 0.7 -0.1 03/29/2007 21:10:00 12.3 1.5 16.1 8.4 12.2 1.5 16.1 8.8 9.5 1.5 14.5 6.5 301 7 303 165 0.4 0 0.7 0.2 03/29/2007 21:20:00 12 1.7 15.6 7.2 12 1.8 16.1 7.2 9.1 1.4 13 5.7 301 8 302 165 0.3 0.1 0.7 0.2 03/29/2007 21:30:00 10.9 1.6 14.9 6.5 10.8 1.6 14.5 6.5 8.2 1.3 13 4.9 297 7 302 165 0.1 0 0.2 -0.1 03/29/2007 21:40:00 10.4 1.8 15.3 6.1 10.3 1.8 14.5 6.5 8.3 1.4 13 4.6 295 8 304 165 0 0.1 0.2 -0.3 03/29/2007 21:50:00 10.2 1.5 13.7 6.1 10.1 1.5 13.7 6.1 8.3 1.5 12.6 4.6 294 9 290 165 0.4 0.2 0.9 -0.1 03/29/2007 22:00:00 9.7 1.4 13 6.1 9.7 1.4 13 6.1 8.5 1.6 12.6 4.9 290 8 291 165 0.4 0 0.7 0.2 03/29/2007 22:10:00 9.3 1.4 13 6.5 9.2 1.4 13 6.1 7.8 1.5 12.6 5.3 292 8 295 165 0.2 0 0.4 -0.1 03/29/2007 22:20:00 9.4 1.5 12.6 5.7 9.4 1.5 12.6 6.1 8.7 1.6 13 4.2 286 8 284 165 0 0 0.2 -0.3 03/29/2007 22:30:00 10.5 1.5 14.1 6.5 10.4 1.5 14.1 6.5 8.9 1.7 13.7 4.9 292 8 297 165 0.1 0 0.2 -0.3 03/29/2007 22:40:00 11.1 1 13.3 9.1 11 1 13.3 9.1 8.5 1.2 11.8 6.1 296 6 293 165 -0.1 0 0.2 -0.3 03/29/2007 22:50:00 12.3 1 14.9 8.8 12.2 1 14.9 8.4 9.1 1.2 13 5.3 299 6 302 165 0.1 0.1 0.4 -0.3 03/29/2007 23:00:00 12.1 0.7 14.1 9.9 12.1 0.8 14.1 9.9 8.5 1 12.2 6.8 302 4 301 165 0.1 0 0.2 -0.1 03/29/2007 23:10:00 12.4 1.5 16.1 9.5 12.3 1.5 15.6 9.1 9.1 1.2 11.8 6.5 303 4 305 165 0.1 0.1 0.4 -0.1 03/29/2007 23:20:00 11.4 1.4 15.3 8 11.3 1.4 14.9 8 9.2 1.3 13 6.5 302 8 298 165 0.2 0 0.7 -0.1 03/29/2007 23:30:00 11.3 1.2 14.5 7.6 11.2 1.2 14.9 7.6 8.6 1.2 11.8 6.1 300 6 306 165 0.1 0.1 0.4 -0.3 03/29/2007 23:40:00 11.3 1.3 15.6 8.8 11.3 1.2 15.3 8.4 8.6 1.5 14.5 6.5 297 6 289 165 0.2 0.1 0.4 -0.1 03/29/2007 23:50:00 10.5 1.5 13.7 6.5 10.5 1.5 13.3 6.5 8.3 1.6 13.3 4.9 295 9 302 165 0.4 0 0.7 0.2 03/30/2007 00:00:00 11.1 1.9 15.6 5.7 11 1.9 16.1 5.3 9.2 2.1 15.3 4.9 294 9 278 165 0.5 0 0.9 0.2 03/30/2007 00:10:00 10.7 1.3 13.7 7.6 10.6 1.3 13.7 7.2 8.3 1.4 12.2 4.9 297 9 283 165 0.2 0.1 0.7 0.2 03/30/2007 00:20:00 10 1.3 13.3 6.8 9.9 1.3 13.3 6.8 7.8 1.1 11.1 5.7 304 6 301 165 0.1 0 0.2 -0.1 03/30/2007 00:30:00 10.6 1.1 14.9 8.4 10.5 1.1 14.5 8.4 7.7 1 11.1 5.7 302 5 293 165 0 0 0.2 -0.3 03/30/2007 00:40:00 10.1 1.5 14.1 6.8 10 1.4 13.7 6.8 8.1 1.5 13 5.3 300 9 295 165 -0.1 0 0.2 -0.3 03/30/2007 00:50:00 7.6 1.6 12.2 3.8 7.5 1.7 11.8 3.8 6.4 1.7 11.5 3.4 302 13 295 165 0.2 0.2 0.7 -0.3 03/30/2007 01:00:00 7.9 1 9.9 5.7 7.8 1 9.9 5.7 6.4 0.9 8.8 4.2 303 9 301 165 0 0 0.2 -0.3 03/30/2007 01:10:00 8.9 1.2 13.7 6.8 8.9 1.2 13 6.5 7.4 1.5 13 4.2 291 7 287 165 -0.1 0.1 0.2 -0.3 03/30/2007 01:20:00 9.5 1.2 12.6 5.7 9.5 1.2 12.6 6.1 7.7 1.4 12.6 4.9 293 9 294 165 0.1 0.1 0.4 -0.1 03/30/2007 01:30:00 7.1 1.3 12.2 3.8 7 1.3 12.6 3 6.5 1.7 11.8 3 291 11 282 165 0.5 0.1 0.9 -0.3 03/30/2007 01:40:00 5.5 1.3 9.9 2.6 5.4 1.3 9.5 2.3 5 1.4 8.4 1.1 288 15 250 165 0.5 0.2 1.1 0.2 03/30/2007 01:50:00 5.2 2.2 9.9 0.4 5 2.2 9.9 0.4 4.6 2 8 0.4 294 17 303 165 0.9 0 1.4 0.7 03/30/2007 02:00:00 7.7 1.5 11.5 4.2 7.6 1.6 11.1 3.8 6.7 1.3 10.3 3.4 303 10 307 165 0.8 0.1 1.1 0.4 03/30/2007 02:10:00 8.6 1.5 14.5 5.3 8.5 1.5 14.9 5.3 6.9 1.4 12.2 4.2 297 11 300 165 0.5 0.1 0.9 0.2 03/30/2007 02:20:00 8.2 1.5 11.8 4.6 8.1 1.4 11.5 4.6 6.6 1.4 10.7 3.4 295 11 302 165 0.2 0.1 0.9 -0.1 03/30/2007 02:30:00 8.1 1.6 11.5 3.4 8 1.6 11.5 3.8 6.5 1.4 11.5 2.3 298 11 289 165 0.2 0.2 0.7 -0.3 03/30/2007 02:40:00 7.9 1 10.7 5.3 7.8 1.1 10.3 5.3 6.5 1.2 9.9 3.8 295 9 301 165 0.4 0.1 0.7 0.2 03/30/2007 02:50:00 7 1.2 10.3 4.6 6.9 1.2 10.3 4.2 5.9 1.1 9.1 3 302 11 305 165 0.5 0 0.7 0.2 03/30/2007 03:00:00 8.7 1 12.2 6.1 8.6 1 11.8 6.1 7.1 1.2 10.3 4.9 306 8 305 165 0.2 0.1 0.7 -0.1 03/30/2007 03:10:00 9.8 0.8 12.2 8 9.8 0.8 11.8 7.6 8.1 1.1 11.1 5.7 307 6 298 165 -0.1 0.1 0.2 -0.3 03/30/2007 03:20:00 9.8 1 13.3 7.6 9.7 1 13 7.6 8.2 1.3 12.2 5.3 307 8 315 165 -0.2 0 -0.1 -0.3 03/30/2007 03:30:00 9.8 0.8 12.2 7.6 9.7 0.8 11.8 7.6 8.7 1 11.5 6.5 310 8 302 165 -0.1 0 0.2 -0.5 03/30/2007 03:40:00 8.4 1.3 12.2 3.8 8.3 1.3 12.2 3.4 7.6 1.3 11.1 3.8 310 14 301 165 0.3 0 0.7 -0.1 03/30/2007 03:50:00 8.9 0.8 11.1 6.8 8.8 0.8 11.1 6.5 7 1 10.3 4.9 301 7 288 165 -0.1 0.1 0.2 -0.3 03/30/2007 04:00:00 9.4 1.5 13 3.8 9.4 1.5 12.6 4.2 7.8 1.3 11.1 4.2 301 10 300 165 0.1 0.1 0.4 -0.3 03/30/2007 04:10:00 9.4 1.3 13.3 6.8 9.4 1.2 13 6.5 7.8 1.5 12.6 4.6 300 9 294 165 0.1 0 0.4 -0.1 03/30/2007 04:20:00 9.9 1.6 14.9 6.1 9.8 1.6 14.5 5.3 8.2 1.8 13.3 4.6 294 9 270 165 0.4 0.2 0.9 -0.3 03/30/2007 04:30:00 11.1 1.5 16.1 7.6 11.1 1.5 15.6 7.6 8.6 1.5 12.6 5.3 301 7 289 165 0.1 0 0.4 -0.1 03/30/2007 04:40:00 9.8 1.3 13 7.6 9.7 1.3 13 7.2 7.8 1.2 11.1 4.6 297 8 297 165 0 0 0.2 -0.3 03/30/2007 04:50:00 9.3 1.7 14.5 5.7 9.3 1.7 14.9 5.3 7.8 1.6 13.7 4.2 295 10 300 165 0.1 0 0.2 -0.3 03/30/2007 05:00:00 8.1 1.8 13 3.4 8 1.8 13 2.6 6.7 1.6 10.3 2.3 301 12 301 165 0.1 0 0.4 -0.3 03/30/2007 05:10:00 7.9 1.6 11.8 4.2 7.8 1.6 11.5 4.2 6.5 1.7 12.2 3.4 295 9 307 165 0.2 0 0.4 -0.1 03/30/2007 05:20:00 7.4 1.3 9.9 3.4 7.2 1.3 9.9 3 6.1 1.3 9.9 2.6 295 11 288 165 0.1 0 0.2 -0.3 03/30/2007 05:30:00 5.5 1.3 8.8 2.3 5.4 1.3 8.4 1.1 4.6 1.3 8.8 1.1 297 13 277 165 0.2 0.1 0.7 -0.1 03/30/2007 05:40:00 5.7 1.2 9.9 2.3 5.6 1.2 9.9 2.6 5.1 1.2 9.5 2.3 291 13 287 165 0.2 0.1 0.7 -0.1 03/30/2007 05:50:00 5.3 1.1 8.8 3 5.3 1.1 8.8 2.6 4.9 1.2 8 2.3 286 12 281 165 0.3 0 0.7 -0.1 03/30/2007 06:00:00 4.9 1 7.6 2.3 4.8 1.1 7.6 1.5 4.6 1.2 8.4 1.9 287 14 284 165 0.3 0 0.7 -0.1 03/30/2007 06:10:00 7.6 1.2 11.1 4.2 7.5 1.2 10.7 3.8 6.3 1.2 10.3 3.4 291 8 290 165 0.1 0 0.4 -0.1 03/30/2007 06:20:00 8.1 0.8 9.9 5.7 8 0.8 9.9 5.7 6.4 1.1 9.1 4.2 295 6 301 165 -0.1 0 0.2 -0.3 03/30/2007 06:30:00 8 1.2 10.7 4.2 8 1.2 10.7 4.9 6.4 1.2 9.5 3.8 293 9 295 165 -0.1 0.1 0.2 -0.3 03/30/2007 06:40:00 8.9 1 11.5 5.7 8.9 1 11.1 6.1 6.7 1 9.5 4.2 298 5 289 165 0 0 0.2 -0.3 03/30/2007 06:50:00 8.2 1.1 10.7 5.7 8.1 1.1 10.3 5.3 6.4 1.1 9.5 3.4 293 8 301 165 0 0 0.2 -0.3 03/30/2007 07:00:00 7.6 1 9.9 4.9 7.5 1 9.9 4.9 6.5 1.1 9.5 3.8 293 8 287 165 0.1 0.1 0.2 -0.3 03/30/2007 07:10:00 7 1.1 9.9 3.4 6.9 1.1 9.5 3.8 6 1 9.5 3.4 295 10 298 165 0.4 0 0.7 0.2 03/30/2007 07:20:00 7.8 1.3 10.7 5.3 7.7 1.3 10.7 4.9 6.9 1.1 10.3 4.2 291 8 295 165 0.6 0 0.9 0.4 03/30/2007 07:30:00 9.1 0.8 11.8 6.1 9 0.8 11.1 6.8 7.1 1 9.9 4.6 298 6 305 165 0.7 0 0.9 0.2 03/30/2007 07:40:00 9.6 0.9 11.5 6.8 9.5 1 11.5 6.5 7.5 0.8 9.9 5.3 301 7 294 165 0.8 0 0.9 0.7 03/30/2007 07:50:00 9.5 1.2 11.5 6.1 9.4 1.2 11.5 6.1 7.3 1.1 9.9 4.6 298 7 298 165 0.8 0 1.1 0.7 03/30/2007 08:00:00 10.6 1.1 13 6.8 10.5 1.1 12.6 6.8 8.4 1.3 13 5.3 295 8 297 165 0.8 0 0.9 0.7 03/30/2007 08:10:00 9.7 1.3 13.3 6.1 9.6 1.3 13.3 6.5 7.6 1.3 11.5 3.8 297 9 282 165 0.9 0 1.1 0.9 03/30/2007 08:20:00 8.2 1.3 10.7 4.6 8.1 1.3 10.7 4.2 6.8 1.5 11.1 3.4 294 11 285 165 1.2 0 1.6 0.9 03/30/2007 08:30:00 6.3 1.1 9.5 3.4 6.1 1.1 9.5 3.4 5.1 1.1 8.8 2.3 292 11 286 165 1.5 0 1.8 1.4 03/30/2007 08:40:00 7 1 9.5 3.4 6.9 1 9.1 3.8 5.6 1 8 3 296 8 304 165 1.3 0 1.6 1.1 03/30/2007 08:50:00 7.8 1.1 9.9 4.6 7.8 1 10.3 4.9 6.8 1.2 9.5 3.8 288 9 295 165 1.2 0 1.4 0.9 03/30/2007 09:00:00 8.3 1.1 10.7 5.3 8.3 1.2 10.7 5.3 7.3 1.3 11.1 3.4 292 7 297 165 1.1 0 1.4 0.9 03/30/2007 09:10:00 9.4 0.8 12.2 7.2 9.5 0.9 12.2 7.2 8.6 1.3 11.5 5.7 291 8 305 165 1 0 1.4 0.9 03/30/2007 09:20:00 9.8 0.9 12.6 7.6 9.8 0.9 12.2 7.6 8.4 1.3 12.2 5.7 292 6 285 165 1.1 0 1.4 0.9 03/30/2007 09:30:00 9.4 0.8 11.5 7.2 9.4 0.8 11.1 7.2 8.3 1.2 11.5 5.3 290 6 289 165 1.3 0 1.4 0.9 03/30/2007 09:40:00 9.6 0.9 11.5 6.5 9.6 0.9 11.5 6.8 9.2 1.4 12.2 5.3 285 6 281 165 1.4 0.1 1.6 0.9 03/30/2007 09:50:00 10.2 0.8 11.8 7.2 10.3 0.8 12.2 7.2 9.5 1.1 11.8 5.7 287 5 287 165 1.3 0.1 1.6 0.9 03/30/2007 10:00:00 10.3 1.1 13.3 7.2 10.3 1.1 13.3 6.5 9.8 1.6 13.7 4.9 287 6 287 165 1.4 0 1.6 1.1 03/30/2007 10:10:00 10.1 0.8 11.8 7.6 10.2 0.8 12.2 7.6 9.3 1.1 11.8 5.7 288 5 289 165 1.5 0 1.8 0.9 03/30/2007 10:20:00 8.8 1 11.1 6.1 8.9 1 11.1 5.7 8.2 1.2 10.7 5.3 286 8 285 165 1.9 0.2 2.3 1.1 03/30/2007 10:30:00 7.4 1.1 10.3 4.2 7.4 1.1 10.7 4.2 6.4 1.5 10.7 3 289 8 284 165 2.2 0.3 2.8 1.6 03/30/2007 10:40:00 5.8 0.8 8 4.2 5.7 0.8 8.4 4.2 4.8 0.8 7.2 3.4 303 11 300 165 3.1 0.3 3.5 2.3 03/30/2007 10:50:00 5.4 0.7 7.6 3.8 5.3 0.7 8 3.4 5.1 0.7 7.6 3.4 315 10 325 165 3.5 0.3 4.3 3 03/30/2007 11:00:00 7.3 1.2 9.5 4.6 7.3 1.2 9.5 4.2 6.2 1 8.8 3.4 304 12 305 165 3.7 0.2 4.3 3.3 03/30/2007 11:10:00 8 1.1 10.3 3.4 8.1 1.1 10.7 3.8 7.2 1.3 10.3 3 293 8 302 165 2.9 0 3.3 2.6 03/30/2007 11:20:00 9 1 11.1 6.5 9.1 1 11.1 6.5 7.7 1.5 11.1 4.2 290 7 278 165 2.6 0 2.8 2.6 03/30/2007 11:30:00 9.4 0.7 11.1 6.8 9.4 0.7 11.1 6.5 8 1.1 11.1 5.3 291 7 289 165 2.5 0 2.8 1.8 03/30/2007 11:40:00 8.3 1 10.7 4.9 8.3 0.9 10.7 5.3 7.3 1.1 10.7 4.6 290 9 297 165 2.7 0 3 2.3 03/30/2007 11:50:00 6.1 1 8.8 3 6.2 1.1 8.8 3 6.2 1.1 9.1 2.3 282 9 271 165 3.5 0.3 4.3 2.8 03/30/2007 12:00:00 4.6 0.9 7.6 2.6 4.5 0.9 7.2 2.6 4.3 1.1 7.6 1.9 294 12 285 165 4.4 0.2 4.8 4 03/30/2007 12:10:00 3.8 1 6.1 1.9 3.7 1.1 6.1 1.1 3.5 0.9 6.8 1.9 316 18 300 165 5.4 0.4 6.2 4.8 03/30/2007 12:20:00 4.2 1.2 6.8 1.5 4.2 1.2 6.8 1.5 3.8 1 6.8 1.9 305 15 305 165 5.2 0.1 5.7 4.8 03/30/2007 12:30:00 3.9 1.1 6.5 1.1 3.9 1.1 6.5 1.1 3.5 1.2 6.8 1.5 298 15 287 165 5.1 0.2 5.5 4.5 03/30/2007 12:40:00 3.9 0.9 6.1 2.3 4 0.9 6.1 2.3 3.5 0.8 5.3 1.5 321 15 302 165 6 0.4 6.7 5 03/30/2007 12:50:00 3.6 0.7 5.3 2.3 3.8 0.6 5.7 2.3 3.7 0.7 5.7 1.9 280 11 282 165 5.4 0.1 5.7 5 03/30/2007 13:00:00 3.4 0.9 5.7 1.1 3.4 0.9 5.7 1.5 3.3 1 6.1 1.1 309 33 355 165 5.8 0.3 6.2 5.2 03/30/2007 13:10:00 3.6 0.8 5.3 1.5 4.1 0.9 6.5 1.5 4 0.9 6.8 2.3 270 15 271 165 5.3 0.2 6 5 03/30/2007 13:20:00 3.6 1 7.2 0.4 3.8 1 7.2 0.4 3.8 1 7.2 1.1 286 30 272 165 5.3 0.1 5.7 5 03/30/2007 13:30:00 2.6 1.7 6.5 0.4 2.7 1.7 6.8 0.4 2.6 1.7 6.8 0.4 323 64 284 165 5.7 0.3 6.2 5 03/30/2007 13:40:00 5.6 1.2 8.4 2.3 5.8 1.2 8 2.3 5.5 1.3 8 1.1 285 13 287 165 4.9 0.3 5.5 4.3 03/30/2007 13:50:00 4.7 1.2 7.2 1.9 5.1 1.2 7.2 1.9 4.9 1.2 7.2 1.9 275 15 287 165 4.5 0.3 5.2 4.3 03/30/2007 14:00:00 4.6 0.8 6.8 3 5.4 1 8 3 5.2 1 7.6 2.3 271 12 270 165 5.2 0.2 6 4.8 03/30/2007 14:10:00 5.5 1.8 9.9 1.9 5.1 1.5 10.3 1.9 5.2 2.1 10.3 1.9 332 29 350 165 5.7 0.2 6.2 5 03/30/2007 14:20:00 5.4 1.1 8 3 5.2 1 7.6 3 5.1 1.1 8 2.6 328 26 328 165 5.7 0.2 6.2 5.2 03/30/2007 14:30:00 4.9 1.2 8 2.6 4.9 1.2 8.4 2.3 4.6 1.2 8 2.6 319 16 341 165 5.5 0.2 6.2 5 03/30/2007 14:40:00 4.7 0.8 6.5 3 4.6 0.8 6.8 3 4.3 0.8 6.8 2.6 315 20 292 165 5.7 0.3 6.2 5 03/30/2007 14:50:00 4.5 0.8 6.5 2.3 4.6 0.8 6.5 2.3 4.5 0.8 6.8 1.9 298 23 295 165 5.2 0.1 5.7 4.8 03/30/2007 15:00:00 4 1.1 6.1 0.4 4.1 1 6.1 0.4 3.7 0.9 6.1 0.7 301 22 284 165 5.5 0.1 6 5.2 03/30/2007 15:10:00 4.8 1.3 7.6 0.4 4.8 1.2 7.2 0.4 4.6 1.5 8 0.4 324 19 322 165 6 0.2 6.7 5.7 03/30/2007 15:20:00 5.4 0.9 8.8 3.4 5.4 1 8.4 3.4 5.5 0.9 8.4 3.4 331 11 322 165 5.6 0 6 5.5 03/30/2007 15:30:00 6.5 1 9.5 4.2 6.5 0.9 9.5 4.6 5.9 1.1 9.1 3.4 311 12 299 165 5.2 0.3 5.7 4.8 03/30/2007 15:40:00 6.7 0.9 9.1 4.6 6.6 0.9 9.1 4.6 6 0.9 8.8 3.4 311 7 304 165 5.2 0.1 5.5 4.8 03/30/2007 15:50:00 5.3 1.1 8.4 3 5.1 1.3 8.4 2.3 5 1.1 8.8 3 331 22 323 165 5.5 0.2 6 5 03/30/2007 16:00:00 5.5 1.6 9.1 2.6 5.4 1.7 9.1 1.9 5.5 1.7 8.8 1.9 333 12 336 165 5.8 0.2 6.7 5.5 03/30/2007 16:10:00 5.2 1.2 7.6 2.6 5.2 1.1 7.6 2.6 5 1.2 7.6 2.3 321 17 352 165 5.5 0.1 6 5.2 03/30/2007 16:20:00 6 1.1 8 3.8 6 1.1 8.4 3.8 5.1 1.3 8 3 306 13 305 165 4.9 0.2 5.7 4.5 03/30/2007 16:30:00 5.8 0.6 7.6 3.8 5.7 0.6 7.2 3.8 5.3 0.8 6.8 3.4 310 11 302 165 5.1 0.2 5.5 4.8 03/30/2007 16:40:00 6.5 1 10.3 3.8 6.5 1 10.7 3.8 6 1.1 8.8 3.4 313 13 288 165 4.8 0.1 5.5 4.5 03/30/2007 16:50:00 5.7 1 8.8 3 5.7 1 8 3 5 0.8 7.6 3.4 312 13 305 165 4.9 0 5.2 4.8 03/30/2007 17:00:00 5.6 1.2 8.8 3.4 5.6 1.2 8.4 3.4 5.3 1.1 8.4 3 318 17 293 165 5.1 0.1 5.5 4.8 03/30/2007 17:10:00 6.3 1 9.1 3.8 6.3 1 8.4 3.4 6.2 1 9.1 3.4 328 17 292 165 4.9 0.2 5.2 4.5 03/30/2007 17:20:00 5.4 0.7 7.2 3.8 5.4 0.7 7.6 3.8 5.3 0.7 7.2 3.8 328 11 309 165 5.2 0 5.5 5 03/30/2007 17:30:00 5 0.7 8.4 3.4 5 0.8 8.4 3 5.1 0.7 8.4 3.4 332 10 329 165 5.2 0 5.5 5 03/30/2007 17:40:00 6 0.7 8.4 4.2 5.7 0.9 8.8 2.6 6 0.8 8.8 4.2 337 13 347 165 5.1 0 5.5 4.8 03/30/2007 17:50:00 5.1 0.9 7.6 2.6 5.2 0.9 7.6 2.6 5.1 0.8 8 2.6 334 10 327 165 4.9 0.1 5.2 4.5 03/30/2007 18:00:00 4.4 0.8 6.5 2.3 4.6 0.8 6.5 2.3 4.4 0.8 6.1 2.6 326 13 333 165 4.7 0.1 5 4.5 03/30/2007 18:10:00 4.8 0.9 6.8 3 4.8 0.9 6.8 2.6 4.4 0.8 6.5 2.6 311 13 310 165 4.4 0.2 5 3.5 03/30/2007 18:20:00 3.9 0.8 6.1 2.3 3.9 0.8 6.1 2.3 3.5 0.7 5.3 1.9 306 9 308 165 4 0.2 4.5 3.5 03/30/2007 18:30:00 3.6 0.6 5.3 1.9 3.6 0.6 5.3 1.9 3.3 0.7 5.3 1.9 311 14 321 165 4.1 0.1 4.5 3.5 03/30/2007 18:40:00 4.7 1.1 6.8 2.3 4.7 1.1 6.5 2.3 4.4 0.9 6.5 2.3 313 10 307 165 3.8 0.1 4.3 3.5 03/30/2007 18:50:00 5.4 0.8 8 4.2 5.4 0.8 8 3.8 5.2 0.8 7.2 3.4 316 7 314 165 3.2 0.2 3.5 2.6 03/30/2007 19:00:00 5.7 0.7 7.6 3.8 5.7 0.7 8 3.8 5.4 0.8 7.2 3 316 9 314 165 3 0.2 3.3 2.6 03/30/2007 19:10:00 4.3 0.9 6.8 2.3 4.3 0.9 6.5 2.3 4 0.8 6.1 2.3 320 12 319 165 3 0.2 3.3 2.6 03/30/2007 19:20:00 3.3 0.6 5.3 1.9 3.2 0.7 5.3 1.1 3.4 0.6 5.3 2.3 340 13 338 165 2.9 0 3 2.6 03/30/2007 19:30:00 3.8 0.9 6.5 2.3 3.7 1 6.5 1.5 3.6 1.1 6.8 1.9 330 14 344 165 2.9 0 3 2.6 03/30/2007 19:40:00 4.2 1 6.8 1.9 4.1 1 6.5 2.3 3.8 1.1 6.5 1.5 314 13 338 165 2.7 0 3 2.6 03/30/2007 19:50:00 4.6 0.8 6.8 2.6 4.6 0.8 7.2 2.6 4.2 0.8 7.2 2.3 310 9 321 165 2.7 0.1 3 2.6 03/30/2007 20:00:00 5.2 0.9 7.6 3 5.1 1 7.2 2.3 4.8 0.8 7.2 2.3 315 11 310 165 2.4 0.2 3 1.8 03/30/2007 20:10:00 6.7 1.1 8.4 2.6 6.6 1.1 8.4 2.3 5.5 1 7.6 3 309 9 302 165 1.8 0.1 2.1 1.4 03/30/2007 20:20:00 6.8 0.5 8.8 5.3 6.8 0.5 8.4 5.7 5.8 0.6 7.2 4.2 310 5 296 165 1.8 0 2.3 1.6 03/30/2007 20:30:00 5.9 1 8 3.8 5.9 1 7.6 3.4 5.2 1 7.2 2.6 308 10 310 165 1.9 0 2.3 1.6 03/30/2007 20:40:00 5.3 0.6 6.8 3.4 5.3 0.6 6.8 3 4.2 0.7 6.5 1.9 297 7 295 165 2.1 0 2.3 1.8 03/30/2007 20:50:00 4.4 0.6 6.1 3 4.3 0.6 5.7 3 3.8 0.6 5.7 2.6 307 8 292 165 1.9 0 2.3 1.6 03/30/2007 21:00:00 4.6 0.7 6.1 2.6 4.5 0.7 6.1 2.6 3.8 0.7 5.3 2.3 307 5 301 165 2 0.2 2.8 1.6 03/30/2007 21:10:00 4 0.8 6.1 2.3 3.9 0.9 6.1 2.3 3.8 0.7 5.7 2.3 318 8 318 165 2.7 0 2.8 2.3 03/30/2007 21:20:00 3.9 0.5 4.9 3 3.8 0.5 4.9 2.6 3.2 0.6 5.3 1.9 307 8 306 165 2.4 0.1 2.8 2.1 03/30/2007 21:30:00 4.8 0.8 6.1 1.9 4.7 0.8 6.5 1.9 4.3 0.9 5.7 1.5 310 8 298 165 2.1 0.2 2.6 1.8 03/30/2007 21:40:00 6.3 0.8 9.1 4.6 6.3 0.8 9.1 3.8 5.1 0.8 7.2 3 305 8 301 165 1.9 0 2.1 1.6 03/30/2007 21:50:00 5.7 0.7 7.6 4.2 5.7 0.7 7.6 4.2 4.3 0.6 6.1 3 300 5 301 165 2 0 2.3 1.8 03/30/2007 22:00:00 4.9 0.5 6.1 2.6 4.8 0.6 6.1 2.6 4 0.6 6.1 2.6 300 8 297 165 2.2 0 2.3 1.8 03/30/2007 22:10:00 4.5 0.7 6.5 2.6 4.4 0.7 6.5 2.6 3.6 0.6 5.3 2.3 304 7 300 165 2.4 0 2.6 2.1 03/30/2007 22:20:00 4.9 0.8 6.5 3 4.8 0.9 6.8 2.6 4 0.9 6.1 2.3 301 9 316 165 2.3 0 2.6 1.8 03/30/2007 22:30:00 4.8 1 6.8 2.3 4.8 1.1 6.8 2.3 3.8 0.8 6.5 1.9 300 6 296 165 1.9 0.1 2.3 1.6 03/30/2007 22:40:00 2.3 0.7 3.4 0.7 2.2 0.6 3.4 0.7 2.5 0.5 3.8 1.1 286 9 293 165 2.4 0.2 2.8 1.8 03/30/2007 22:50:00 2.6 0.7 4.9 1.1 2.6 0.7 4.9 1.1 1.7 0.8 4.6 0.4 277 10 271 165 1.7 0.5 2.8 0.9 03/30/2007 23:00:00 3.5 0.8 5.3 0.7 3.5 0.8 5.3 0.7 3 0.8 4.6 0.4 280 11 270 165 0.9 0 1.1 0.9 03/30/2007 23:10:00 2.3 0.6 3.4 0.7 2.2 0.6 3.4 0.4 1.7 0.7 3.4 0.4 275 24 276 165 0.9 0.2 1.6 0.7 03/30/2007 23:20:00 1.6 0.6 2.6 0.4 1.6 0.6 2.6 0.4 1.9 0.4 3 0.7 301 20 293 165 2.2 0.3 2.8 1.4 03/30/2007 23:30:00 1.5 0.5 3 0.4 1.5 0.6 3 0.4 1.9 0.6 3 0.4 293 36 274 165 2.3 0.2 2.8 1.8 03/30/2007 23:40:00 1.2 0.5 2.6 0.4 1.2 0.5 2.6 0.4 1.6 0.5 2.6 0.4 304 24 280 165 2.2 0 2.6 1.8 03/30/2007 23:50:00 2 0.6 3.8 0.4 2 0.7 3.8 0.4 2.3 0.7 3.8 0.7 294 29 296 165 2 0.1 2.6 1.6 03/31/2007 00:00:00 3.4 0.8 4.9 1.1 3.5 0.9 5.3 1.5 3.9 0.7 5.3 2.3 276 9 269 165 2 0 2.3 1.8 03/31/2007 00:10:00 2.9 0.8 4.2 0.7 2.9 0.8 4.2 0.4 3.2 0.5 4.2 1.9 283 9 279 165 1.8 0 2.3 1.4 03/31/2007 00:20:00 3.2 0.7 4.9 1.9 3.2 0.7 4.9 1.9 3.6 0.7 5.3 2.3 280 8 276 165 1.7 0 1.8 1.6 03/31/2007 00:30:00 2.8 0.8 4.6 0.7 3 0.8 4.9 0.7 3.4 0.6 4.9 1.9 273 11 273 165 2 0.1 2.3 1.6 03/31/2007 00:40:00 3.6 0.6 4.9 2.3 3.5 0.6 4.9 2.3 3.6 0.6 4.9 1.9 278 6 277 165 1.7 0.2 1.8 1.4 03/31/2007 00:50:00 5.9 1.2 8.4 3 5.9 1.2 8.4 3 5.6 1.2 8.4 1.9 282 7 281 165 2 0.1 2.3 1.6 03/31/2007 01:00:00 6 0.6 7.6 3.8 5.9 0.7 8 3.4 5 1 8 2.6 294 8 291 165 2.3 0 2.6 2.1 03/31/2007 01:10:00 5.5 0.9 7.6 3.4 5.4 0.9 7.2 3 4.5 0.9 6.8 2.6 296 9 287 165 2.3 0.1 2.6 1.8 03/31/2007 01:20:00 4.7 0.9 6.5 2.6 4.6 1 6.8 2.6 3.9 0.8 6.5 2.3 304 12 296 165 2.4 0 2.6 2.1 03/31/2007 01:30:00 4.5 0.9 6.8 2.3 4.4 1 6.8 1.9 3.5 0.8 6.1 1.9 298 10 284 165 2.1 0.2 2.6 1.8 03/31/2007 01:40:00 3.8 0.7 5.3 1.9 3.6 0.8 5.3 1.9 3 0.6 4.6 1.1 301 10 317 165 1.7 0 1.8 1.6 03/31/2007 01:50:00 3.2 0.8 4.9 1.1 3 0.9 4.9 0.7 2.7 0.8 4.2 0.7 294 12 288 165 1.7 0 1.8 1.6 03/31/2007 02:00:00 2.5 0.8 4.2 0.7 2.2 0.8 4.2 0.4 2 0.7 3.8 0.4 295 16 310 165 1.2 0.2 1.8 0.9 03/31/2007 02:10:00 1.7 1.1 4.6 0.4 1.6 1.1 4.9 0.4 1.2 0.8 3.8 0.4 264 30 292 165 0.7 0.3 1.4 0.2 03/31/2007 02:20:00 3.2 0.8 5.7 1.9 3.1 0.9 6.1 1.1 2.5 0.7 4.6 1.1 293 12 302 165 1.1 0.3 1.4 0.2 03/31/2007 02:30:00 4.3 1 6.5 1.9 4.2 1 6.8 1.5 3.8 1 6.1 1.5 287 7 291 165 1.4 0.1 1.6 0.9 03/31/2007 02:40:00 4.6 0.6 6.1 3 4.5 0.6 6.1 2.6 3.6 0.6 5.7 2.3 292 7 288 165 1.5 0.1 1.8 1.4 03/31/2007 02:50:00 4.8 0.5 5.7 3.8 4.7 0.5 5.7 3.4 3.8 0.5 5.3 2.6 302 7 288 165 1.4 0 1.8 1.4 03/31/2007 03:00:00 4.3 0.7 6.8 2.6 4.1 0.8 6.5 2.6 3.4 0.6 5.3 2.3 302 7 302 165 1.5 0 1.8 1.4 03/31/2007 03:10:00 3.6 1 5.7 1.1 3.3 1.1 5.7 0.7 2.9 0.9 4.6 1.1 304 11 298 165 1.5 0 1.8 1.1 03/31/2007 03:20:00 3.1 0.7 4.9 1.5 2.8 0.7 5.3 0.7 2.6 0.7 4.2 1.1 306 13 307 165 0.9 0.1 1.4 0.7 03/31/2007 03:30:00 2.3 0.5 3.4 1.1 2.1 0.6 3.4 0.7 2 0.6 3.4 0.4 311 13 302 165 0.6 0 0.9 0.2 03/31/2007 03:40:00 2.7 0.6 4.2 1.1 2.6 0.6 3.8 0.7 2.5 0.5 3.8 1.1 290 13 279 165 0.8 0 1.1 0.7 03/31/2007 03:50:00 1.8 0.8 4.6 0.4 1.7 0.9 4.6 0.4 1.7 0.8 4.2 0.4 247 20 258 165 1 0.1 1.4 0.7 03/31/2007 04:00:00 1.1 0.8 3.8 0.4 1 0.8 3.4 0.4 1 0.6 3 0.4 267 20 277 165 0.7 0 0.9 0.7 03/31/2007 04:10:00 2.3 0.8 4.6 0.4 2.3 0.8 4.6 0.4 2.2 0.6 3.8 0.7 283 19 293 165 1.1 0.2 1.6 0.4 03/31/2007 04:20:00 2.4 1 4.2 0.4 2.2 1 4.2 0.4 2.1 0.7 3.8 0.4 293 11 295 165 1.2 0.1 1.4 0.9 03/31/2007 04:30:00 2.9 0.6 4.6 1.5 2.7 0.6 4.2 1.1 2.4 0.5 3.8 1.1 301 11 314 165 1.3 0.1 1.6 0.9 03/31/2007 04:40:00 3.5 0.8 5.7 1.5 3.3 0.9 5.7 1.1 2.7 0.7 4.9 1.1 299 9 305 165 1.5 0 1.6 1.4 03/31/2007 04:50:00 3.1 0.7 4.9 1.5 2.9 0.8 4.9 1.1 2.5 0.6 4.6 1.5 302 10 309 165 1.8 0.1 2.1 1.4 03/31/2007 05:00:00 2.8 0.7 4.6 1.5 2.5 0.7 4.2 0.7 2.4 0.5 3.4 1.5 302 13 307 165 1.7 0.1 1.8 1.4 03/31/2007 05:10:00 1.4 0.7 3.4 0.4 1.3 0.7 3 0.4 1.6 0.5 3.4 0.4 301 16 292 165 2.1 0.1 2.6 1.6 03/31/2007 05:20:00 1.6 0.4 2.6 0.4 1.4 0.4 2.6 0.4 1.7 0.4 2.3 0.7 292 15 283 165 2.4 0 2.6 2.1 03/31/2007 05:30:00 1.9 0.4 3.4 1.1 1.8 0.5 3 0.7 2.2 0.6 3.4 1.1 289 12 273 165 2.4 0 2.8 2.1 03/31/2007 05:40:00 2.3 0.6 3.8 0.7 2.3 0.6 3.8 0.7 2.2 0.5 3.8 1.1 283 9 280 165 2.4 0.3 2.8 1.8 03/31/2007 05:50:00 2.6 0.6 3.8 0.7 2.5 0.6 3.8 1.1 2.4 0.6 4.2 1.1 283 8 304 165 2 0.2 2.6 1.8 03/31/2007 06:00:00 1.4 0.5 3.4 0.4 1.2 0.6 3 0.4 1.6 0.4 3 0.7 273 7 288 165 2.4 0.1 2.6 1.8 03/31/2007 06:10:00 3.2 0.6 4.6 1.5 3.1 0.7 4.6 0.7 2.6 0.5 4.2 1.5 291 4 290 165 1.8 0 2.3 1.6 03/31/2007 06:20:00 2.6 0.6 3.8 1.1 2.5 0.6 3.8 1.1 2.6 0.5 3.4 1.1 289 6 291 165 2 0 2.3 1.6 03/31/2007 06:30:00 2.3 1.1 4.6 0.4 2.1 1.1 4.9 0.4 2.3 0.7 5.3 0.7 305 16 314 165 2.1 0 2.3 1.8 03/31/2007 06:40:00 3.6 1.1 6.1 1.5 3.5 1.1 6.1 1.5 3.1 1 5.7 1.5 290 8 287 165 1.8 0.1 2.3 1.6 03/31/2007 06:50:00 4.8 0.6 6.5 3 4.7 0.7 6.1 3 4.1 0.6 5.7 3 308 9 290 165 1.2 0.2 1.8 0.9 03/31/2007 07:00:00 4.5 0.8 6.8 3 4.3 0.9 6.8 2.3 3.7 0.6 5.3 2.3 308 9 298 165 1.2 0.1 1.4 0.9 03/31/2007 07:10:00 4.1 0.7 6.8 2.6 4 0.8 6.8 2.3 3.4 0.7 5.3 1.5 314 14 317 165 1.6 0.2 2.1 1.1 03/31/2007 07:20:00 3.2 0.8 6.5 1.5 3 0.9 6.1 1.1 3.1 0.6 4.9 1.9 326 14 300 165 2.4 0.1 2.8 1.8 03/31/2007 07:30:00 3.1 0.7 5.3 1.5 3 0.8 5.3 1.1 2.9 0.7 5.7 1.5 306 11 309 165 3.1 0.1 3.5 2.6 03/31/2007 07:40:00 3.3 0.9 6.5 1.5 3.2 0.9 5.7 1.5 2.9 0.9 5.7 1.5 298 11 319 165 3.2 0.2 3.5 2.8 03/31/2007 07:50:00 3.5 0.8 5.7 1.9 3.5 0.8 6.1 1.9 3 0.6 4.9 1.5 299 12 296 165 3.2 0 3.5 3 03/31/2007 08:00:00 3.4 0.8 6.1 1.9 3.3 0.8 5.7 1.9 2.9 0.9 5.7 1.5 308 12 328 165 3.8 0.2 4.3 3.3 03/31/2007 08:10:00 3.7 0.8 6.1 1.5 3.6 0.8 5.7 1.5 3.1 0.7 5.3 1.1 297 11 286 165 3.9 0 4.3 3.8 03/31/2007 08:20:00 3.4 0.7 4.9 1.5 3.3 0.7 4.9 1.5 3 0.7 4.9 1.5 308 12 313 165 3.6 0.1 4 3.3 03/31/2007 08:30:00 3.3 0.9 5.3 1.5 3.3 0.9 5.3 1.5 2.6 0.7 4.6 1.1 304 12 296 165 4 0.1 4.3 3.8 03/31/2007 08:40:00 3.2 0.9 6.8 1.5 3.3 0.9 6.5 1.5 2.7 0.7 4.9 1.1 296 13 308 165 4.3 0 4.5 3.8 03/31/2007 08:50:00 2.9 0.9 4.9 0.4 2.9 0.8 4.6 0.4 2.3 0.6 3.8 0.4 300 11 300 165 4.4 0.1 4.8 4.3 03/31/2007 09:00:00 3.5 1 6.1 1.1 3.5 1 5.7 1.1 2.8 0.9 4.9 0.7 302 10 299 165 4.3 0.2 4.8 3.5 03/31/2007 09:10:00 1.8 0.8 3.8 0.4 2 0.7 3.8 0.7 1.7 0.6 3.4 0.4 285 19 282 165 5 0.4 5.7 4.3 03/31/2007 09:20:00 2.6 1 5.7 0.7 2.8 0.9 5.7 1.1 2.4 0.7 4.6 0.4 282 17 287 165 5.1 0.2 5.7 4.5 03/31/2007 09:30:00 3 1 5.7 0.7 3.1 0.9 5.7 1.1 2.6 0.9 4.9 1.1 281 11 287 165 5.1 0.3 5.7 4.5 03/31/2007 09:40:00 2.9 0.7 4.9 1.5 2.9 0.7 4.9 1.5 2.2 0.6 4.2 0.7 289 9 284 165 5.2 0.1 6 4.8 03/31/2007 09:50:00 1.7 0.7 3.4 0.4 2 0.6 3.4 0.7 1.2 0.8 3 0.4 276 14 307 165 6.4 0.5 7.3 5.2 03/31/2007 10:00:00 2.1 0.5 3 0.7 2.3 0.4 3.4 1.1 2.1 0.4 2.6 1.1 275 12 274 165 5.9 0.2 6.7 5.7 03/31/2007 10:10:00 1.7 0.5 3 0.7 1.9 0.4 3 0.7 1.7 0.3 3 0.7 268 20 301 165 6.2 0.2 7 6 03/31/2007 10:20:00 1.9 0.5 3 0.7 2.2 0.4 3.4 1.1 2 0.4 3 1.1 267 15 300 165 5.8 0.1 6.7 5.5 03/31/2007 10:30:00 2.1 0.6 3.8 1.1 2.5 0.6 3.8 1.1 2.5 0.5 3.8 1.1 260 10 278 165 5.6 0.2 6 5.2 03/31/2007 10:40:00 2.6 0.7 5.7 1.1 3 0.7 5.3 1.5 2.7 0.7 4.6 1.1 271 13 283 165 6.1 0.1 6.7 5.7 03/31/2007 10:50:00 2.7 0.7 4.9 1.1 3.1 0.7 4.9 1.1 3 0.7 4.9 1.1 253 17 272 165 5.8 0.1 6.2 5.5 03/31/2007 11:00:00 2.4 0.7 4.6 0.7 2.8 0.8 4.9 1.1 2.5 0.9 4.9 0.4 262 16 261 165 6.2 0.2 7 5.7 03/31/2007 11:10:00 3.8 0.8 5.7 1.9 4.3 0.7 5.7 2.6 3.8 0.6 5.3 1.9 272 9 285 165 6.1 0 6.7 6 03/31/2007 11:20:00 4.4 0.9 6.5 1.5 4.6 0.7 6.5 2.6 4.2 0.8 6.1 2.3 281 9 291 165 6.2 0.2 6.5 5.7 03/31/2007 11:30:00 4.5 0.5 5.7 2.6 4.5 0.5 5.7 2.3 4.1 0.7 5.7 2.3 288 8 277 165 6.2 0 6.2 6 03/31/2007 11:40:00 5.4 0.5 6.8 3.8 5.4 0.5 6.8 3.8 4.6 0.9 6.8 2.3 292 6 293 165 5.9 0 6.2 5.7 03/31/2007 11:50:00 6.1 0.6 7.6 4.9 6.2 0.5 7.6 4.9 5.4 0.7 6.8 3.8 292 4 292 165 5.6 0 6 5.5 03/31/2007 12:00:00 5.7 0.6 7.2 3.4 5.8 0.7 7.2 3.4 4.7 0.9 6.8 3 296 6 293 165 5.7 0.1 6.2 5.5 03/31/2007 12:10:00 5.4 0.6 7.2 4.2 5.5 0.6 7.2 4.2 5.1 0.8 6.8 3 288 4 290 165 5.5 0.1 6 5 03/31/2007 12:20:00 6.5 0.5 7.6 4.6 6.6 0.5 7.6 4.6 6 0.6 7.6 4.2 288 4 285 165 5 0 5.2 4.8 03/31/2007 12:30:00 6.6 0.4 8 5.3 6.7 0.4 8 5.7 6.1 0.6 7.6 4.9 290 4 294 165 4.9 0 5 4.8 03/31/2007 12:40:00 7.1 0.6 8.4 5.7 7.2 0.6 8.4 5.7 5.7 0.8 7.6 3.8 296 6 296 165 4.9 0 5 4.8 03/31/2007 12:50:00 5.8 0.6 7.2 4.2 5.8 0.6 7.2 4.2 4.4 0.6 6.1 3 298 5 299 165 5.1 0 5.7 4.8 03/31/2007 13:00:00 5.9 0.7 7.6 3.8 5.9 0.8 8 3.8 4.6 0.7 6.5 3 296 8 301 165 5.3 0 5.5 5 03/31/2007 13:10:00 6.9 0.7 8.8 4.9 6.9 0.7 8.8 4.9 5.5 0.9 8 3.8 301 6 304 165 5.1 0 5.7 4.8 03/31/2007 13:20:00 7.8 0.9 9.9 5.3 7.9 0.9 9.9 5.7 5.8 0.7 7.6 3.8 298 5 298 165 4.9 0 5.2 4.8 03/31/2007 13:30:00 8.2 0.6 9.5 6.5 8.3 0.6 9.5 6.5 6.9 1.2 9.5 4.2 292 5 295 165 4.8 0.1 5.2 4.5 03/31/2007 13:40:00 8.1 1 10.3 5.7 8.2 1 10.3 5.7 7 1.4 9.9 4.2 295 6 300 165 4.8 0 5 4.8 03/31/2007 13:50:00 7.8 1 9.9 4.9 7.9 1 10.3 4.9 6.9 1.2 9.9 3.4 290 6 300 165 4.9 0 5 4.8 03/31/2007 14:00:00 7.7 0.6 9.1 6.1 7.7 0.6 9.5 6.1 6.4 0.8 8.8 4.9 295 6 282 165 4.9 0 5.2 4.8 03/31/2007 14:10:00 7.7 0.5 9.1 5.7 7.8 0.5 9.1 6.1 6.1 0.9 8.4 4.6 297 5 286 165 5 0 5.5 4.8 03/31/2007 14:20:00 7.7 0.6 9.1 5.7 7.7 0.6 9.1 6.1 6.4 0.9 9.1 4.2 295 5 293 165 5.1 0 5.2 4.8 03/31/2007 14:30:00 7.9 0.7 9.9 6.5 7.9 0.7 9.9 6.5 6.6 1 8.8 4.6 295 5 302 165 5.2 0 5.5 5 03/31/2007 14:40:00 7.4 0.7 9.5 5.3 7.5 0.7 9.5 5.7 6.1 0.9 9.1 3.8 298 7 289 165 5.4 0 5.7 5.2 03/31/2007 14:50:00 6.7 1 9.1 4.6 6.7 1 9.5 4.6 5.8 1 9.1 3.4 302 10 299 165 5.6 0.1 5.7 5.2 03/31/2007 15:00:00 4.7 1.1 6.8 2.6 4.7 1.1 6.8 2.6 4.1 0.9 6.8 2.3 312 18 294 165 6.2 0.2 6.7 5.7 03/31/2007 15:10:00 5.2 0.9 7.6 3 5.2 0.8 7.6 3.4 4.6 0.8 6.5 3 312 11 310 165 6.3 0 6.7 6.2 03/31/2007 15:20:00 4.8 0.8 6.8 3 4.8 0.8 6.8 3 4.2 0.9 6.8 1.9 314 14 328 165 6.6 0 6.7 6.2 03/31/2007 15:30:00 6.6 1 8.8 4.2 6.6 1 8.4 4.6 5.7 0.7 8 3.8 309 8 300 165 6.2 0.3 6.7 5.7 03/31/2007 15:40:00 6.6 0.9 8.8 3.8 6.6 0.9 9.1 3.8 5.5 0.8 8 3 303 9 297 165 5.5 0.1 6.2 5.2 03/31/2007 15:50:00 5.1 0.9 6.8 2.6 5.2 0.9 6.8 3 4.5 0.6 6.5 3 307 11 293 165 5.6 0.2 6 5.2 03/31/2007 16:00:00 6.5 1 9.1 4.2 6.5 1 8.8 4.6 5.5 1 8.4 3.4 307 9 298 165 5.9 0 6 5.7 03/31/2007 16:10:00 7.9 1.1 10.3 4.6 7.9 1 9.9 4.6 6.2 0.8 9.1 4.2 303 7 297 165 5.7 0.1 6 5.5 03/31/2007 16:20:00 7.1 1.5 10.7 3.8 7.1 1.4 10.7 3.8 6.2 1 8.8 3.4 308 11 294 165 6 0.2 6.2 5.7 03/31/2007 16:30:00 4.4 1 8 2.3 4.3 1.1 7.6 1.9 4 0.7 6.5 2.6 324 22 297 165 6.4 0.4 7 5.7 03/31/2007 16:40:00 5.2 0.9 7.6 3.4 5.2 0.9 7.6 3.4 4.5 0.8 6.8 2.6 306 11 312 165 6 0.1 6.2 5.7 03/31/2007 16:50:00 4.6 1 7.2 2.6 4.7 1 7.2 2.6 4.4 0.9 7.2 2.3 301 19 288 165 5.7 0 6 5.5 03/31/2007 17:00:00 4.3 1.3 6.8 1.1 4.4 1.3 6.8 1.5 3.7 1.1 6.8 1.5 300 15 297 165 5.8 0 6 5.5 03/31/2007 17:10:00 3.3 0.9 6.1 1.5 3.4 0.9 6.1 1.1 3 0.8 5.7 1.5 302 16 294 165 5.7 0.1 6 5 03/31/2007 17:20:00 4.1 1 7.6 1.5 4.1 1 7.6 1.5 3.7 1 6.8 1.5 300 13 300 165 5.7 0 6 5.2 03/31/2007 17:30:00 3.5 1 6.1 1.1 3.6 1 6.5 1.1 3.3 0.7 5.3 1.9 299 16 282 165 5.8 0.1 6.2 5.7 03/31/2007 17:40:00 2.9 1 5.3 0.7 3 1 5.3 1.1 2.5 0.8 4.6 0.7 305 18 309 165 5.8 0.1 6.2 5.2 03/31/2007 17:50:00 2.4 1 4.6 0.4 2.6 0.9 4.9 0.4 2.5 0.7 4.6 0.4 305 14 307 165 5.6 0.1 6.2 5.2 03/31/2007 18:00:00 2.5 1.1 4.9 0.4 2.8 1 5.3 0.4 2.5 0.8 4.9 0.4 296 19 283 165 5.1 0.1 5.5 4.8 03/31/2007 18:10:00 3.5 1.2 6.1 0.4 3.7 1.1 6.1 1.1 3.3 0.9 5.7 1.1 303 14 300 165 4.9 0 5.5 4.5 03/31/2007 18:20:00 4.6 0.8 6.1 2.3 4.7 0.8 6.1 2.3 3.9 0.7 5.3 1.9 312 9 302 165 4.8 0.1 5 4.3 03/31/2007 18:30:00 4.9 0.9 7.6 3 5 0.8 7.6 3.4 4.3 0.9 6.5 2.3 311 9 309 165 4.3 0.1 5 3.8 03/31/2007 18:40:00 2.8 0.7 5.3 1.1 2.9 0.7 4.9 1.5 3 0.6 4.9 1.5 325 17 323 165 4.3 0.3 4.8 3.8 03/31/2007 18:50:00 1.6 0.9 3.8 0.4 1.8 0.8 3.8 0.4 2.1 0.6 3.4 0.7 337 26 337 165 4.7 0.2 5 4.3 03/31/2007 19:00:00 1.2 0.6 2.6 0.4 1.6 0.6 3 0.4 1.7 0.6 3 0.4 340 47 297 165 4.8 0.2 5.2 4.3 03/31/2007 19:10:00 2.8 1.6 6.1 0.4 3 1.5 6.1 0.4 2.8 1.3 6.5 0.7 322 22 328 165 4.7 0.3 5.2 3.8 03/31/2007 19:20:00 5 0.5 6.5 3.4 5.1 0.5 6.5 3.8 4.4 0.6 5.7 2.6 309 9 316 165 4 0 4.3 3.5 03/31/2007 19:30:00 4.9 0.8 6.8 2.3 5 0.8 6.5 2.3 4.5 0.7 6.5 2.6 312 11 305 165 3.8 0 4.3 3.5 03/31/2007 19:40:00 2.9 1.6 6.5 0.4 3.1 1.6 6.8 0.4 3 1.1 6.1 0.7 318 22 294 165 4.1 0 4.5 3.8 03/31/2007 19:50:00 0.9 0.6 3 0.4 1.5 0.6 3.4 0.4 1.9 0.6 3.4 0.4 303 26 322 165 4.3 0 4.8 4.3 03/31/2007 20:00:00 0.9 0.6 2.3 0.4 1.3 0.7 3 0.4 2 0.5 3.8 0.7 308 39 262 165 4.3 0.2 4.8 4 03/31/2007 20:10:00 0.4 0.1 1.1 0.4 0.5 0.3 2.3 0.4 0.8 0.5 2.3 0.4 345 76 277 165 4.3 0 4.5 4 03/31/2007 20:20:00 0.4 0 0.7 0.4 0.4 0.2 1.5 0.4 0.6 0.4 1.9 0.4 43 47 36 165 4.4 0 4.5 3.8 03/31/2007 20:30:00 0.4 0.2 1.5 0.4 0.7 0.5 2.6 0.4 0.8 0.6 3 0.4 166 61 240 165 4.3 0 4.8 4.3 03/31/2007 20:40:00 1 0.6 2.6 0.4 1.3 0.8 3 0.4 1.6 0.8 3.4 0.4 201 26 230 165 4.4 0 4.8 4 03/31/2007 20:50:00 0.6 0.3 1.5 0.4 0.8 0.4 1.9 0.4 1.2 0.3 1.9 0.4 142 10 159 165 4.1 0 4.3 4 03/31/2007 21:00:00 0.7 0.3 1.5 0.4 1.1 0.4 1.9 0.4 1.6 0.2 1.9 1.1 142 5 143 165 4.2 0 4.5 4 03/31/2007 21:10:00 0.4 0.1 1.1 0.4 0.7 0.3 1.5 0.4 1.2 0.4 1.9 0.4 134 24 122 165 4 0 4.5 3.5 03/31/2007 21:20:00 0.4 0.2 1.5 0.4 0.5 0.3 1.9 0.4 0.8 0.5 2.6 0.4 191 30 156 165 4 0 4.3 3.8 03/31/2007 21:30:00 1.7 0.9 3 0.4 2.1 1 3.4 0.4 1.7 0.7 3 0.4 287 22 300 165 3.7 0.1 4 3.5 03/31/2007 21:40:00 2.6 0.5 3.8 1.5 3 0.5 4.2 1.9 2.6 0.6 4.6 1.1 294 5 292 165 4 0.1 4.3 3.5 03/31/2007 21:50:00 1.4 0.4 2.3 0.7 2 0.3 2.6 1.1 2.1 0.4 3 1.1 306 13 292 165 4 0 4.3 3.8 03/31/2007 22:00:00 0.7 0.4 2.3 0.4 1.3 0.4 2.6 0.4 1.4 0.4 2.3 0.7 298 11 293 165 4.1 0.1 4.5 3.8 03/31/2007 22:10:00 0.6 0.3 1.9 0.4 1.2 0.5 2.3 0.4 1.3 0.3 2.3 0.7 296 7 283 165 4.3 0 4.5 4.3 03/31/2007 22:20:00 0.5 0.3 1.5 0.4 1 0.5 2.3 0.4 1.5 0.3 2.3 0.7 323 12 310 165 3.7 0.2 4.3 3.5 03/31/2007 22:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.5 0.2 1.1 0.4 319 8 165 165 3.5 0 3.8 3.3 03/31/2007 22:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0.1 0.7 0.4 282 9 165 165 3.4 0 3.5 3.3 03/31/2007 22:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.6 0.3 1.1 0.4 216 26 165 165 3.3 0 3.5 3 03/31/2007 23:00:00 0.4 0.1 1.5 0.4 0.4 0.2 1.9 0.4 0.5 0.2 1.1 0.4 197 18 234 165 3.1 0 3.3 2.8 03/31/2007 23:10:00 0.4 0 0.7 0.4 0.5 0.3 1.5 0.4 0.7 0.2 1.1 0.4 216 23 208 165 3 0 3.3 2.8 03/31/2007 23:20:00 0.4 0.1 1.1 0.4 0.6 0.4 1.9 0.4 1 0.3 1.5 0.4 244 8 258 165 3 0.1 3.5 2.8 03/31/2007 23:30:00 0.4 0.2 1.1 0.4 1.1 0.5 1.9 0.4 1.5 0.3 2.3 1.1 248 11 238 165 3.5 0 3.8 3.3 03/31/2007 23:40:00 0.5 0.3 1.5 0.4 0.9 0.7 2.3 0.4 0.9 0.6 2.3 0.4 287 11 286 165 3.3 0.1 3.8 3 03/31/2007 23:50:00 0.9 0.8 3 0.4 1.5 0.9 3.4 0.4 1.4 0.8 3.8 0.4 270 15 292 165 3.8 0 4.3 3.5 04/01/2007 00:00:00 2.8 0.7 4.9 1.9 3.3 0.7 4.9 2.3 3 0.7 5.3 1.1 285 8 282 165 3.6 0 3.8 3.5 04/01/2007 00:10:00 3.8 0.5 4.9 2.3 4.2 0.5 5.3 2.6 4.1 0.6 5.7 2.3 279 6 293 165 3.5 0.2 4.3 3.3 04/01/2007 00:20:00 4.1 0.5 5.7 2.6 4.3 0.5 5.3 3 4.1 0.8 6.1 1.9 285 6 287 165 3.7 0.3 4.3 3.3 04/01/2007 00:30:00 4.2 0.5 5.7 3 4.6 0.6 6.1 3.4 4.7 0.6 6.1 3 281 6 276 165 3.8 0.3 4.3 3 04/01/2007 00:40:00 4.4 0.4 5.7 3.4 4.7 0.4 5.7 3.8 4.8 0.4 6.1 3.4 280 6 281 165 3.9 0 4.3 3.8 04/01/2007 00:50:00 3.9 0.5 5.3 2.3 4.1 0.4 5.7 2.6 3.9 0.7 5.7 1.9 283 6 281 165 3.8 0.2 4.3 3.5 04/01/2007 01:00:00 3.6 0.4 4.6 2.6 3.7 0.4 4.6 2.6 3.7 0.6 4.9 2.3 288 5 284 165 3.5 0 3.8 3.3 04/01/2007 01:10:00 2.6 0.7 3.8 1.1 2.8 0.6 4.2 1.5 2.4 0.7 4.2 1.1 294 9 292 165 3.5 0 3.5 3.3 04/01/2007 01:20:00 2.5 0.4 3.4 1.5 2.7 0.4 3.8 1.9 2.4 0.3 3.4 1.5 302 6 290 165 3.3 0 3.5 3 04/01/2007 01:30:00 2.3 0.4 3.8 1.1 2.5 0.4 4.2 1.9 2.6 0.3 3.8 1.9 314 7 318 165 3.1 0 3.3 3 04/01/2007 01:40:00 2.1 0.5 3 1.1 2.3 0.6 3.4 0.7 2.7 0.4 3.4 1.9 337 16 313 165 2.7 0 3 2.6 04/01/2007 01:50:00 0.8 0.3 1.5 0.4 1.2 0.4 2.3 0.4 1.7 0.2 2.3 1.1 4 12 1 165 2.9 0 3 2.6 04/01/2007 02:00:00 0.4 0.1 1.1 0.4 0.6 0.4 1.9 0.4 1 0.5 1.9 0.4 32 16 29 165 3.2 0 3.3 2.8 04/01/2007 02:10:00 0.4 0.1 1.1 0.4 0.4 0.2 1.5 0.4 0.5 0.2 1.1 0.4 169 76 208 165 3.6 0.2 4.3 3.3 04/01/2007 02:20:00 0.4 0.1 1.5 0.4 0.4 0.2 1.9 0.4 0.7 0.4 1.5 0.4 210 29 201 165 4 0 4.3 3.8 04/01/2007 02:30:00 0.4 0.1 0.7 0.4 0.5 0.3 1.1 0.4 0.6 0.3 1.5 0.4 160 14 141 165 3.8 0.1 4.3 3.5 04/01/2007 02:40:00 0.7 0.4 1.5 0.4 1.2 0.3 1.9 0.7 1.3 0.2 1.9 0.7 136 8 154 165 3.6 0 3.8 3.5 04/01/2007 02:50:00 0.5 0.2 1.1 0.4 1 0.3 1.9 0.4 1.3 0.3 1.9 0.4 146 6 144 165 3.5 0 3.8 3.5 04/01/2007 03:00:00 0.4 0.1 1.1 0.4 0.5 0.3 1.9 0.4 0.6 0.3 1.5 0.4 17 122 262 165 3.7 0 4 3.5 04/01/2007 03:10:00 0.7 0.5 2.3 0.4 1.1 0.7 2.6 0.4 1 0.6 2.6 0.4 271 11 284 165 3.6 0.1 3.8 3.3 04/01/2007 03:20:00 1.7 0.6 3 0.4 2.3 0.5 3 1.1 2.2 0.4 3 1.1 279 5 277 165 3.5 0 3.8 3.3 04/01/2007 03:30:00 0.4 0.2 1.5 0.4 0.7 0.5 2.3 0.4 0.9 0.5 2.3 0.4 292 11 277 165 3.3 0.1 3.8 3 04/01/2007 03:40:00 0.4 0 0.4 0.4 0.4 0.1 1.1 0.4 0.7 0.3 1.5 0.4 22 102 165 165 3.2 0 3.5 3 04/01/2007 03:50:00 0.4 0 0.4 0.4 0.9 0.3 1.5 0.4 1.1 0.1 1.5 0.7 145 7 165 165 3.4 0 3.5 3.3 04/01/2007 04:00:00 0.4 0 0.4 0.4 0.9 0.3 1.5 0.4 1 0.3 1.5 0.4 126 5 165 165 3.3 0 3.5 3.3 04/01/2007 04:10:00 0.4 0 0.4 0.4 0.4 0.1 0.7 0.4 0.5 0.2 1.1 0.4 120 0 165 165 3.5 0 3.5 3.3 04/01/2007 04:20:00 0.4 0 0.4 0.4 0.9 0.2 1.1 0.4 1.1 0.2 1.5 0.7 120 0 165 165 3.5 0 3.5 3.3 04/01/2007 04:30:00 0.4 0 0.4 0.4 0.4 0.2 1.1 0.4 0.6 0.3 1.1 0.4 120 0 165 165 3.4 0 3.5 3.3 04/01/2007 04:40:00 0.5 0.2 1.1 0.4 1.2 0.2 1.5 0.7 1.4 0.2 1.9 0.7 120 0 121 165 3.5 0 3.5 3.3 04/01/2007 04:50:00 0.4 0 0.4 0.4 1.1 0.3 1.5 0.4 1.2 0.2 1.9 0.7 120 0 165 165 3.3 0 3.5 3 04/01/2007 05:00:00 0.4 0 0.4 0.4 0.6 0.2 1.1 0.4 0.9 0.3 1.5 0.4 147 15 165 165 3.3 0 3.5 3 04/01/2007 05:10:00 0.4 0 0.4 0.4 0.7 0.3 1.1 0.4 0.7 0.3 1.1 0.4 157 0 165 165 3.2 0 3.5 3 04/01/2007 05:20:00 0.4 0 0.4 0.4 0.4 0 0.7 0.4 0.6 0.2 1.1 0.4 157 0 165 165 3.2 0 3.5 3 04/01/2007 05:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0.1 1.1 0.4 157 0 165 165 3.4 0 3.5 3.3 04/01/2007 05:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0.1 0.7 0.4 157 0 165 165 3.4 0 3.5 3.3 04/01/2007 05:50:00 0.4 0 0.4 0.4 0.5 0.3 1.1 0.4 0.7 0.3 1.1 0.4 154 6 165 165 3.3 0 3.5 3 04/01/2007 06:00:00 0.4 0 0.4 0.4 0.8 0.3 1.5 0.4 0.9 0.3 1.5 0.4 137 0 165 165 3 0.1 3.3 2.8 04/01/2007 06:10:00 0.4 0 0.4 0.4 0.4 0.1 0.7 0.4 0.5 0.2 1.1 0.4 137 0 165 165 3.2 0 3.5 3 04/01/2007 06:20:00 0.4 0 0.4 0.4 0.4 0.1 0.7 0.4 0.5 0.2 0.7 0.4 137 0 165 165 2.7 0.2 3.3 2.3 04/01/2007 06:30:00 0.4 0 0.4 0.4 0.7 0.3 1.1 0.4 0.9 0.3 1.5 0.4 137 0 165 165 2.9 0 3 2.8 04/01/2007 06:40:00 0.4 0 0.4 0.4 1.2 0.2 1.5 0.7 1.2 0.2 1.9 0.7 133 4 165 165 2.9 0 3.3 2.8 04/01/2007 06:50:00 0.5 0.2 1.1 0.4 1.2 0.2 1.5 0.7 1.3 0.2 1.5 1.1 128 0 128 165 2.9 0 3.3 2.8 04/01/2007 07:00:00 0.5 0.2 1.1 0.4 1.2 0.3 1.9 0.4 1.3 0.2 1.9 0.7 128 0 128 165 3.1 0 3.3 3 04/01/2007 07:10:00 0.4 0 0.7 0.4 0.8 0.2 1.5 0.4 0.9 0.2 1.5 0.4 128 2 128 165 3.3 0 3.5 3 04/01/2007 07:20:00 0.6 0.5 2.6 0.4 1 0.6 3 0.4 1 0.6 2.6 0.4 93 11 71 165 3.3 0 3.5 3 04/01/2007 07:30:00 0.4 0 0.7 0.4 0.5 0.3 1.5 0.4 0.5 0.2 1.1 0.4 89 1 88 165 3.3 0 3.5 3 04/01/2007 07:40:00 0.4 0 0.4 0.4 0.4 0.1 1.1 0.4 0.4 0.2 1.1 0.4 91 0 165 165 3.3 0 3.5 3.3 04/01/2007 07:50:00 0.4 0 0.4 0.4 0.4 0.1 1.1 0.4 0.4 0.1 0.7 0.4 97 5 165 165 3.3 0 3.5 3.3 04/01/2007 08:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0.1 0.7 0.4 94 0 165 165 3.4 0 3.5 3.3 04/01/2007 08:10:00 0.4 0 0.4 0.4 0.4 0 0.7 0.4 0.8 0.2 1.1 0.4 120 18 165 165 3.5 0 3.8 3.5 04/01/2007 08:20:00 0.5 0.2 1.1 0.4 1 0.4 1.5 0.4 1.3 0.3 1.9 0.7 162 17 180 165 3.6 0 3.8 3.5 04/01/2007 08:30:00 0.9 0.2 1.5 0.4 1.6 0.2 1.9 1.1 1.8 0.2 2.3 1.5 191 4 193 165 3.7 0 3.8 3.5 04/01/2007 08:40:00 1 0.2 1.5 0.7 1.7 0.2 2.3 1.1 1.7 0.2 2.3 1.1 203 6 196 165 3.8 0 4 3.5 04/01/2007 08:50:00 0.8 0.2 1.5 0.4 1.6 0.2 1.9 1.1 1.9 0.3 2.3 1.5 223 4 225 165 4 0 4.3 3.8 04/01/2007 09:00:00 0.5 0.2 1.1 0.4 1.3 0.4 1.9 0.4 1.8 0.3 2.3 1.1 225 0 225 165 4 0 4.3 3.8 04/01/2007 09:10:00 0.4 0 0.4 0.4 0.8 0.2 1.5 0.4 1.5 0.2 1.9 1.1 225 0 165 165 4.2 0 4.5 4 04/01/2007 09:20:00 0.4 0 0.4 0.4 0.6 0.3 1.5 0.4 1.1 0.4 1.9 0.4 220 5 165 165 4.5 0.1 4.8 4.3 04/01/2007 09:30:00 0.4 0 0.4 0.4 0.5 0.2 1.1 0.4 0.9 0.3 1.5 0.4 215 0 165 165 4.9 0.1 5.2 4.3 04/01/2007 09:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.6 0.2 1.1 0.4 215 0 165 165 5.2 0.1 5.5 4.5 04/01/2007 09:50:00 0.4 0 0.4 0.4 0.4 0.1 1.1 0.4 0.8 0.3 1.5 0.4 215 0 165 165 5.2 0.1 5.5 4.8 04/01/2007 10:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.7 0.3 1.5 0.4 215 1 165 165 5.2 0.2 5.5 4.5 04/01/2007 10:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 214 1 165 165 5.7 0.1 6 5.5 04/01/2007 10:20:00 0.4 0 0.4 0.4 0.4 0.1 0.7 0.4 0.4 0.1 1.1 0.4 211 10 165 165 6.7 0.4 7.3 5.7 04/01/2007 10:30:00 0.4 0 0.4 0.4 0.4 0 0.7 0.4 0.6 0.3 1.5 0.4 178 1 165 165 6.1 0.4 7.3 5.7 04/01/2007 10:40:00 0.6 0.5 1.9 0.4 1 0.4 1.9 0.4 1.3 0.4 2.3 0.4 179 11 180 165 5.7 0.1 6 5.5 04/01/2007 10:50:00 1.9 0.5 3 0.7 1.8 0.5 3 0.7 2 0.4 3 0.7 159 9 173 165 5 0 5.5 4.3 04/01/2007 11:00:00 1 0.3 1.9 0.4 1 0.4 1.9 0.4 1 0.3 1.9 0.4 186 15 203 165 5.2 0.3 6 4.8 04/01/2007 11:10:00 0.7 0.4 1.9 0.4 0.9 0.5 2.3 0.4 1.2 0.4 2.6 0.4 167 15 157 165 6.2 0 6.2 5.7 04/01/2007 11:20:00 0.4 0.1 1.1 0.4 0.5 0.2 1.1 0.4 0.7 0.4 1.9 0.4 171 13 196 165 5.9 0.1 6.5 5.7 04/01/2007 11:30:00 0.4 0.1 1.1 0.4 0.6 0.4 1.9 0.4 0.7 0.4 1.9 0.4 205 29 227 165 7.2 0.3 7.8 6.2 04/01/2007 11:40:00 1.6 0.4 2.6 0.4 1.6 0.4 2.6 0.4 1.6 0.4 2.6 0.7 226 15 236 165 6.6 0.3 7.3 6.2 04/01/2007 11:50:00 1.1 0.6 2.3 0.4 1 0.6 2.3 0.4 1.2 0.6 2.6 0.4 184 26 222 165 7.1 0.2 7.5 6.7 04/01/2007 12:00:00 1.1 0.5 2.3 0.4 1.2 0.5 2.3 0.4 1.3 0.5 2.3 0.4 207 19 248 165 7.4 0.1 8 7.3 04/01/2007 12:10:00 1.1 0.6 2.3 0.4 1.1 0.6 2.3 0.4 1.3 0.6 2.6 0.4 179 14 184 165 7.2 0 7.8 7 04/01/2007 12:20:00 1.1 0.5 2.3 0.4 1.2 0.5 2.3 0.4 1.5 0.4 2.6 0.4 174 19 171 165 7.2 0 7.5 7 04/01/2007 12:30:00 2 0.5 3.4 0.7 1.9 0.6 3.4 0.4 2.1 0.5 3 1.1 170 12 165 165 6.8 0.1 7.3 6.5 04/01/2007 12:40:00 1.8 0.5 3 0.4 1.8 0.5 3.4 0.7 1.9 0.5 3 0.7 175 12 165 165 6.9 0.2 7.8 6.5 04/01/2007 12:50:00 1.4 0.4 2.6 0.4 1.4 0.5 2.6 0.4 1.7 0.4 2.6 0.7 173 12 171 165 7.3 0 7.8 7 04/01/2007 13:00:00 1.5 0.6 2.6 0.4 1.5 0.6 2.6 0.4 1.7 0.5 2.6 0.4 173 12 174 165 6.9 0.1 7.3 6.7 04/01/2007 13:10:00 2.3 0.4 3.4 1.5 2.3 0.4 3.4 1.5 2.4 0.4 3.4 1.5 164 6 165 165 6.4 0.2 7 6 04/01/2007 13:20:00 2 0.4 3.4 1.1 1.9 0.5 3.4 1.1 2.1 0.4 3.4 1.1 166 9 174 165 6.2 0.1 6.5 6 04/01/2007 13:30:00 2.5 0.5 3.8 1.1 2.5 0.5 3.8 1.1 2.7 0.5 4.2 1.5 155 11 164 165 5.9 0.3 6.5 5.2 04/01/2007 13:40:00 1.9 0.3 2.6 1.1 1.8 0.4 2.6 1.1 1.9 0.3 2.6 1.1 153 10 148 165 5.4 0.2 6 5.2 04/01/2007 13:50:00 1.8 0.4 2.6 0.7 1.8 0.4 2.6 0.7 1.9 0.4 2.6 1.1 161 9 157 165 6.4 0.2 6.7 6 04/01/2007 14:00:00 1.8 0.5 3 0.7 1.8 0.5 3 0.7 1.8 0.5 3 0.4 167 14 145 165 6.7 0.1 7 6.5 04/01/2007 14:10:00 1.6 0.5 3 0.4 1.7 0.5 3 0.4 1.7 0.5 3 0.4 172 18 154 165 7.3 0.2 7.8 6.7 04/01/2007 14:20:00 1 0.6 2.3 0.4 0.9 0.6 2.3 0.4 1.2 0.5 2.3 0.4 156 11 162 165 7.6 0.1 8 7.3 04/01/2007 14:30:00 0.7 0.4 1.9 0.4 0.8 0.4 1.9 0.4 1 0.3 1.5 0.4 162 9 164 165 8.3 0.1 8.5 7.8 04/01/2007 14:40:00 1.1 0.7 2.6 0.4 1.1 0.6 2.6 0.4 1.3 0.7 3 0.4 159 9 162 165 7.9 0.3 8.5 7.3 04/01/2007 14:50:00 1 0.3 1.9 0.4 0.9 0.3 1.5 0.4 1.1 0.3 1.9 0.4 150 5 145 165 7.3 0.1 7.5 7 04/01/2007 15:00:00 0.9 0.4 1.9 0.4 0.8 0.4 1.9 0.4 1 0.4 1.9 0.4 164 0 162 165 7.1 0 7.5 7 04/01/2007 15:10:00 0.4 0.1 1.1 0.4 0.4 0.1 0.7 0.4 0.5 0.2 1.1 0.4 164 0 164 165 7.8 0.1 8 7.3 04/01/2007 15:20:00 1 0.4 1.9 0.4 0.9 0.4 1.9 0.4 1.1 0.4 2.3 0.4 156 3 162 165 7.6 0.2 8.3 7.3 04/01/2007 15:30:00 1.4 0.6 3 0.4 1.3 0.6 3 0.4 1.6 0.7 3 0.4 152 8 159 165 7.2 0.6 8 5.7 04/01/2007 15:40:00 1.2 0.2 1.9 0.7 1 0.2 1.5 0.7 1.2 0.3 1.9 0.7 151 6 150 165 5.6 0.1 6.2 5.2 04/01/2007 15:50:00 1.4 0.2 1.9 0.7 1.3 0.2 1.9 0.7 1.3 0.3 1.9 0.7 141 9 125 165 5.9 0.2 6.7 5.5 04/01/2007 16:00:00 1.7 0.2 2.3 1.1 1.6 0.3 2.3 0.7 1.6 0.3 2.6 0.7 135 13 132 165 6.1 0.2 6.7 5.7 04/01/2007 16:10:00 1.9 0.4 3 1.1 1.8 0.3 2.6 0.7 2 0.4 3 1.1 139 16 166 165 5.4 0.3 6 5 04/01/2007 16:20:00 2.1 0.3 3 1.1 2.1 0.4 3 1.5 2.3 0.3 3 1.5 142 9 137 165 4.9 0 5.2 4.8 04/01/2007 16:30:00 2 0.2 2.6 1.5 2 0.2 2.6 1.5 1.9 0.3 2.6 1.1 129 9 124 165 4.5 0 4.8 4.3 04/01/2007 16:40:00 1.9 0.2 2.3 1.5 1.8 0.2 2.3 1.1 1.8 0.2 2.6 1.1 142 6 145 165 4.3 0 4.5 4.3 04/01/2007 16:50:00 2.1 0.2 2.6 1.5 2 0.2 2.3 1.5 1.8 0.2 2.3 1.1 141 4 144 165 4.5 0 4.8 4.3 04/01/2007 17:00:00 2 0.2 2.6 1.5 1.9 0.2 2.3 1.5 1.8 0.2 2.6 1.1 143 7 154 165 4.3 0 4.5 4.3 04/01/2007 17:10:00 2.1 0.2 2.6 1.5 2.1 0.2 2.6 1.5 1.9 0.2 2.6 1.5 153 5 157 165 4.2 0.1 4.5 4 04/01/2007 17:20:00 2.2 0.2 2.6 1.5 2.1 0.2 2.6 1.5 2.1 0.2 2.6 1.5 145 5 154 165 3.8 0 4.3 3.8 04/01/2007 17:30:00 2.3 0.2 2.6 1.5 2.2 0.2 2.6 1.5 2.2 0.2 2.6 1.9 135 5 135 165 3.7 0.1 4 3.3 04/01/2007 17:40:00 2.2 0.2 2.6 1.5 2.2 0.2 2.6 1.5 2.2 0.2 3 1.5 127 6 135 165 3.8 0 3.8 3.5 04/01/2007 17:50:00 2.3 0.3 3 1.5 2.3 0.3 3 1.5 2.3 0.3 3 1.9 123 4 124 165 3.6 0 3.8 3.5 04/01/2007 18:00:00 2.8 0.2 3.4 2.3 2.8 0.2 3.4 2.3 2.8 0.2 3.4 2.3 124 3 126 165 3.4 0.2 3.8 2.8 04/01/2007 18:10:00 2.4 0.3 3 1.5 2.5 0.3 3 1.9 2.5 0.3 3.4 1.9 117 8 128 165 3.2 0.1 3.5 2.8 04/01/2007 18:20:00 1.8 0.3 2.3 1.1 1.9 0.2 2.3 1.5 2 0.2 2.6 1.5 105 4 107 165 3 0.1 3.3 2.6 04/01/2007 18:30:00 1.5 0.2 1.9 1.1 1.7 0.2 2.3 1.1 1.8 0.2 2.3 1.5 85 15 103 165 2.9 0.1 3.3 2.3 04/01/2007 18:40:00 0.9 0.3 1.5 0.4 0.9 0.3 1.5 0.4 1.2 0.2 1.9 0.7 53 4 59 165 3.2 0 3.5 2.6 04/01/2007 18:50:00 1.2 0.3 1.9 0.4 1.4 0.3 2.3 0.7 1.5 0.3 2.3 0.7 83 12 90 165 3 0.1 3.5 2.6 04/01/2007 19:00:00 1.5 0.2 1.9 1.1 1.7 0.2 2.3 1.5 1.8 0.2 2.3 1.5 90 4 84 165 2.9 0.1 3.3 2.3 04/01/2007 19:10:00 1.5 0.2 1.9 1.1 1.8 0.2 2.3 1.5 1.8 0.2 2.3 1.5 95 1 94 165 2.6 0.1 3 2.3 04/01/2007 19:20:00 1.5 0.2 1.9 1.1 1.8 0.2 2.3 1.5 1.9 0.2 2.3 1.5 99 2 97 165 2.7 0 3 2.6 04/01/2007 19:30:00 1.6 0.2 2.3 1.1 2 0.2 2.3 1.5 2 0.2 2.3 1.5 84 11 85 165 2.7 0 3 2.3 04/01/2007 19:40:00 1.2 0.4 1.9 0.4 1.7 0.3 2.3 0.4 1.9 0.3 2.6 0.7 50 16 60 165 2.7 0 3 2.6 04/01/2007 19:50:00 0.6 0.3 1.9 0.4 1.1 0.3 2.3 0.4 1.2 0.3 1.9 0.4 67 12 63 165 2.8 0 3 2.6 04/01/2007 20:00:00 0.7 0.4 1.9 0.4 1.2 0.3 2.3 0.4 1.4 0.3 2.3 0.7 63 9 59 165 2.8 0.1 3 2.3 04/01/2007 20:10:00 1.1 0.3 1.9 0.4 1.5 0.3 2.3 0.7 1.7 0.3 2.3 1.1 55 13 63 165 2.7 0 2.8 2.3 04/01/2007 20:20:00 0.7 0.3 1.5 0.4 1.2 0.3 1.9 0.4 1.5 0.3 2.3 0.7 39 6 29 165 2.3 0 2.8 2.1 04/01/2007 20:30:00 0.5 0.2 1.5 0.4 1.1 0.3 1.9 0.4 1.3 0.2 1.9 1.1 46 10 40 165 2 0.1 2.3 1.8 04/01/2007 20:40:00 0.8 0.3 1.5 0.4 1.3 0.2 1.9 0.7 1.7 0.2 2.3 1.1 27 5 15 165 1.8 0.1 2.1 1.6 04/01/2007 20:50:00 0.6 0.3 1.5 0.4 1.1 0.2 1.5 0.4 1.6 0.2 2.3 1.1 24 4 15 165 1.9 0.1 2.1 1.6 04/01/2007 21:00:00 1.2 0.2 1.9 0.4 1.3 0.3 2.3 0.7 2 0.2 2.3 1.5 9 4 3 165 1.8 0.1 2.3 1.6 04/01/2007 21:10:00 1.5 0.2 1.9 0.7 1.9 0.3 2.6 1.1 2.2 0.2 2.6 1.9 23 5 14 165 1.9 0 2.3 1.8 04/01/2007 21:20:00 1.4 0.2 1.9 1.1 1.9 0.2 2.3 1.5 2.3 0.2 2.6 1.9 23 5 26 165 1.9 0 2.3 1.6 04/01/2007 21:30:00 1.8 0.3 2.3 1.1 2.1 0.3 2.6 1.5 2.6 0.3 3 2.3 17 1 15 165 1.8 0 2.1 1.6 04/01/2007 21:40:00 1.3 0.2 1.5 1.1 1.8 0.2 2.3 1.5 2.2 0.2 2.6 1.9 19 2 18 165 1.8 0 1.8 1.6 04/01/2007 21:50:00 1.1 0.2 1.5 0.4 1.6 0.2 1.9 1.1 2 0.2 2.6 1.5 19 2 22 165 1.7 0 1.8 1.6 04/01/2007 22:00:00 0.8 0.4 1.9 0.4 1.5 0.3 2.3 0.7 1.7 0.3 2.3 0.7 48 24 75 165 1.7 0.1 1.8 1.4 04/01/2007 22:10:00 1.1 0.4 1.9 0.4 1.7 0.3 2.3 1.1 1.7 0.3 2.3 1.1 81 7 91 165 1.8 0.1 2.3 1.4 04/01/2007 22:20:00 1 0.4 1.9 0.4 1.6 0.3 2.3 1.1 1.8 0.3 2.3 1.1 76 3 81 165 2 0.1 2.3 1.6 04/01/2007 22:30:00 1.5 0.2 1.9 1.1 2 0.2 2.3 1.5 2.1 0.2 2.6 1.5 75 3 74 165 1.8 0.1 2.3 1.4 04/01/2007 22:40:00 1.2 0.2 1.5 0.7 1.8 0.2 2.3 1.5 1.7 0.2 2.3 1.1 88 2 84 165 1.8 0.1 2.1 1.4 04/01/2007 22:50:00 1.3 0.2 1.9 1.1 1.9 0.2 2.3 1.5 2 0.3 2.6 1.1 85 5 90 165 2 0 2.3 1.4 04/01/2007 23:00:00 0.8 0.3 1.9 0.4 1.4 0.3 2.3 0.4 1.7 0.2 2.3 1.1 20 8 46 165 1.8 0 2.3 1.6 04/01/2007 23:10:00 1.1 0.5 2.3 0.4 1.7 0.5 2.6 0.4 2.1 0.4 2.6 1.1 30 13 31 165 1.8 0.1 2.1 1.4 04/01/2007 23:20:00 1.4 0.3 2.3 0.7 1.6 0.3 2.3 0.7 2.2 0.2 3 1.9 19 8 19 165 1.4 0.1 1.8 1.1 04/01/2007 23:30:00 1.4 0.5 2.3 0.4 1.4 0.4 2.3 0.4 2.3 0.3 3 1.5 10 10 6 165 1.3 0 1.4 0.9 04/01/2007 23:40:00 1.2 0.3 1.9 0.4 1.6 0.2 2.3 1.1 2.1 0.2 2.6 1.5 20 5 19 165 1.2 0.1 1.4 0.9 04/01/2007 23:50:00 0.6 0.3 1.5 0.4 1.3 0.3 1.9 0.4 1.7 0.2 2.3 1.1 28 4 39 165 1.3 0.1 1.6 0.9 04/02/2007 00:00:00 1.3 0.3 2.3 0.4 1.8 0.3 2.3 1.1 2.3 0.3 2.6 1.5 22 4 16 165 1 0.3 1.6 0.2 04/02/2007 00:10:00 2 0.4 2.6 1.1 2.3 0.3 3 1.9 2.9 0.3 3.4 2.3 17 1 16 165 0.6 0.1 0.9 -0.1 04/02/2007 00:20:00 2.2 0.2 2.6 1.9 2.5 0.2 3 1.9 3.1 0.2 3.4 2.6 20 4 20 165 0.5 0 0.9 -0.1 04/02/2007 00:30:00 2.2 0.3 3 1.5 2.7 0.3 3.4 1.9 3.1 0.3 3.8 2.6 31 4 34 165 0.6 0 0.9 -0.1 04/02/2007 00:40:00 2.5 0.3 3 1.1 2.9 0.3 3.4 1.9 3.2 0.2 3.8 2.3 38 7 33 165 0.4 0.2 0.9 -0.1 04/02/2007 00:50:00 1.8 0.5 3.4 0.7 2.2 0.4 3.4 1.1 2.4 0.5 3.4 1.5 75 9 51 165 -0.1 0 0.4 -0.5 04/02/2007 01:00:00 2.8 1 4.6 1.1 3.3 1 5.3 1.9 3.2 0.9 4.9 1.5 93 9 89 165 0.1 0.2 0.7 -0.5 04/02/2007 01:10:00 4.1 0.4 4.9 2.6 4.4 0.4 5.3 3 4.3 0.4 5.3 3 102 5 101 165 0.5 0 0.7 -0.1 04/02/2007 01:20:00 3.6 0.2 4.2 3 4.1 0.2 4.6 3.4 4 0.3 4.6 3.4 102 3 106 165 0.4 0 0.7 -0.1 04/02/2007 01:30:00 3.3 0.2 3.8 3 3.7 0.2 4.2 3.4 3.7 0.2 4.2 3.4 101 1 103 165 0.4 0 0.7 -0.3 04/02/2007 01:40:00 3.1 0.2 3.4 2.6 3.5 0.2 3.8 3 3.4 0.2 3.8 3 103 1 103 165 0.4 0.1 0.7 -0.3 04/02/2007 01:50:00 2.7 0.1 3 2.3 3.2 0.2 3.4 2.6 3.1 0.2 3.4 2.6 103 2 102 165 0.3 0.1 0.7 -0.3 04/02/2007 02:00:00 2.6 0.2 3 2.3 3.1 0.2 3.4 2.6 3 0.2 3.4 2.6 107 2 105 165 0.3 0 0.7 0.2 04/02/2007 02:10:00 2.5 0.2 2.6 2.3 3 0.2 3.4 2.6 2.9 0.2 3.4 2.6 102 1 105 165 0.3 0 0.7 0.2 04/02/2007 02:20:00 2.2 0.2 2.6 1.5 2.7 0.2 3 2.3 2.7 0.2 3 2.3 103 2 102 165 0.2 0 0.7 0.2 04/02/2007 02:30:00 1.9 0.2 2.3 1.5 2.6 0.2 3 2.3 2.6 0.2 3 2.3 96 1 98 165 0.2 0 0.4 -0.1 04/02/2007 02:40:00 2.5 0.6 3.8 1.5 3 0.6 4.2 2.3 3 0.5 4.2 2.3 84 8 74 165 0.1 0 0.2 -0.3 04/02/2007 02:50:00 3.4 0.3 4.2 2.6 3.8 0.3 4.6 3 3.8 0.3 4.6 3 74 5 78 165 0.2 0 0.4 -0.1 04/02/2007 03:00:00 3.3 0.3 3.8 2.6 3.8 0.3 4.6 3 3.8 0.3 4.6 3 69 4 68 165 0.2 0 0.4 -0.1 04/02/2007 03:10:00 3.4 0.3 4.2 2.6 3.8 0.3 4.6 3 3.9 0.3 4.6 3.4 76 4 70 165 0.1 0 0.4 -0.1 04/02/2007 03:20:00 3.1 0.3 4.2 2.3 3.5 0.3 4.6 2.6 3.6 0.3 4.2 2.6 70 5 73 165 0.2 0 0.4 -0.1 04/02/2007 03:30:00 3.1 0.3 3.8 2.3 3.5 0.2 4.2 3 3.5 0.3 4.2 3 65 3 73 165 0.4 0 0.7 0.2 04/02/2007 03:40:00 3.3 0.2 3.8 2.6 3.6 0.2 4.2 3 3.7 0.2 4.6 3 76 5 65 165 0.4 0 0.7 0.2 04/02/2007 03:50:00 3.2 0.3 3.8 2.6 3.5 0.3 4.2 3 3.7 0.3 4.6 3 87 4 87 165 0.5 0 0.7 0.2 04/02/2007 04:00:00 2.9 0.2 3.4 2.6 3.4 0.2 3.8 3 3.5 0.2 3.8 3 89 2 86 165 0.5 0 0.9 0.2 04/02/2007 04:10:00 2.8 0.2 3 2.6 3.3 0.2 3.8 3 3.4 0.2 3.8 3 92 1 89 165 0.5 0 0.7 0.4 04/02/2007 04:20:00 2.9 0.2 3.4 2.6 3.3 0.2 3.8 3 3.5 0.2 4.2 3.4 92 1 91 165 0.5 0 0.7 0.4 04/02/2007 04:30:00 3 0.2 3.4 2.6 3.4 0.2 3.8 3 3.6 0.2 3.8 3.4 89 1 89 165 0.5 0 0.7 0.2 04/02/2007 04:40:00 3.1 0.2 3.4 2.6 3.5 0.2 3.8 3 3.7 0.2 4.2 3.4 91 2 87 165 0.5 0 0.7 0.2 04/02/2007 04:50:00 2.8 0.2 3.4 2.3 3.3 0.2 3.8 3 3.4 0.2 3.8 3 93 1 91 165 0.5 0 0.7 0.2 04/02/2007 05:00:00 2.8 0.2 3 2.3 3.3 0.2 3.8 3 3.4 0.2 3.8 2.6 95 2 97 165 0.6 0 0.9 0.4 04/02/2007 05:10:00 3 0.2 3.4 2.6 3.4 0.2 3.8 3 3.6 0.2 4.2 3 85 4 84 165 0.3 0.1 0.7 0.2 04/02/2007 05:20:00 3.1 0.2 3.4 2.6 3.5 0.2 3.8 3 3.7 0.2 4.2 3 85 3 84 165 0.4 0 0.7 -0.1 04/02/2007 05:30:00 3 0.4 3.8 1.9 3.4 0.4 4.2 2.3 3.5 0.5 4.6 2.6 71 7 84 165 0.4 0 0.7 0.2 04/02/2007 05:40:00 3.1 0.3 3.8 2.3 3.4 0.3 4.2 2.6 3.5 0.3 4.2 2.6 72 4 73 165 0.4 0 0.7 0.2 04/02/2007 05:50:00 3.1 0.3 3.8 2.6 3.5 0.2 4.2 3 3.5 0.3 4.2 3 71 4 70 165 0.4 0 0.7 0.2 04/02/2007 06:00:00 2.9 0.3 3.8 2.3 3.3 0.3 4.2 2.6 3.3 0.4 4.2 2.6 59 3 56 165 0.3 0 0.7 0.2 04/02/2007 06:10:00 3.2 0.6 4.6 1.9 3.4 0.5 4.6 2.3 3.5 0.6 4.6 2.3 55 5 60 165 0.3 0 0.4 0.2 04/02/2007 06:20:00 3.5 0.3 4.2 2.6 3.8 0.2 4.2 3 3.9 0.3 4.6 3 64 4 59 165 0.3 0 0.7 0.2 04/02/2007 06:30:00 3.2 0.4 4.2 2.3 3.6 0.3 4.6 3 3.7 0.3 4.6 3 61 3 62 165 0.3 0 0.7 0.2 04/02/2007 06:40:00 2.9 0.3 3.8 2.3 3.5 0.2 4.2 2.6 3.5 0.3 4.2 2.6 67 9 65 165 0.5 0 0.7 0.2 04/02/2007 06:50:00 2.8 0.2 3.4 2.3 3.3 0.2 4.2 2.6 3.2 0.2 3.8 2.6 65 7 72 165 0.5 0 0.7 0.4 04/02/2007 07:00:00 3 0.3 3.8 2.6 3.6 0.3 4.6 3 3.4 0.3 4.2 3 70 4 73 165 0.6 0 0.9 0.4 04/02/2007 07:10:00 2.6 0.3 3 1.9 3.1 0.3 3.8 2.6 2.9 0.3 3.8 2.3 64 6 70 165 0.7 0 0.9 0.7 04/02/2007 07:20:00 2.7 0.3 3.4 1.9 3.2 0.4 4.2 2.6 3 0.3 3.8 2.3 65 6 62 165 0.6 0 0.9 0.4 04/02/2007 07:30:00 3.1 0.3 3.8 2.3 3.6 0.3 4.2 3 3.4 0.3 4.2 2.6 73 5 76 165 0.7 0 0.9 0.7 04/02/2007 07:40:00 2.8 0.4 3.4 1.9 3.3 0.4 4.2 2.3 3.1 0.5 3.8 2.3 64 6 73 165 0.8 0 0.9 0.7 04/02/2007 07:50:00 2.6 0.4 3.4 1.9 3.1 0.4 4.2 2.3 2.9 0.4 3.8 1.9 70 6 74 165 0.8 0 0.9 0.7 04/02/2007 08:00:00 2.2 0.2 2.6 1.5 2.6 0.2 3 2.3 2.5 0.2 3 2.3 61 3 59 165 0.8 0 1.1 0.7 04/02/2007 08:10:00 2.3 0.3 3 1.9 2.6 0.3 3.4 1.9 2.6 0.2 3.4 1.9 53 4 53 165 0.8 0 0.9 0.7 04/02/2007 08:20:00 2.5 0.3 3.4 1.9 2.9 0.3 3.8 1.9 2.9 0.3 3.4 1.9 49 5 45 165 0.8 0 1.1 0.7 04/02/2007 08:30:00 2.6 0.5 4.2 1.5 3 0.6 4.9 1.5 2.8 0.5 4.6 1.9 63 8 74 165 1 0 1.4 0.9 04/02/2007 08:40:00 2.5 0.7 4.2 0.7 2.9 0.8 4.6 1.1 2.9 0.7 4.6 1.5 72 11 73 165 1.3 0 1.6 0.9 04/02/2007 08:50:00 2.2 0.6 3.4 0.4 2.4 0.6 3.8 0.7 2.5 0.5 3.8 1.1 64 10 70 165 1.4 0 1.6 1.4 04/02/2007 09:00:00 2.6 0.5 4.2 1.1 2.8 0.6 4.6 1.1 2.9 0.6 4.6 1.5 86 16 94 165 1.4 0 1.6 1.4 04/02/2007 09:10:00 3.1 0.6 4.9 1.9 3.6 0.6 4.9 2.3 3.4 0.6 4.9 2.3 97 12 97 165 1.4 0 1.6 1.4 04/02/2007 09:20:00 3.2 0.5 4.6 1.9 3.6 0.5 5.3 2.3 3.4 0.5 4.9 2.3 95 10 96 165 1.4 0 1.6 1.4 04/02/2007 09:30:00 2.9 0.6 4.2 1.5 3.2 0.6 4.6 1.9 3 0.6 4.2 1.1 102 12 66 165 1.5 0 1.6 1.4 04/02/2007 09:40:00 3 0.5 4.6 1.9 3.2 0.5 4.6 1.9 3.1 0.5 4.6 1.9 108 8 109 165 1.5 0 1.6 1.4 04/02/2007 09:50:00 3.4 0.6 4.9 1.9 3.6 0.7 5.3 1.9 3.3 0.6 4.6 1.9 108 10 114 165 1.6 0 1.8 1.6 04/02/2007 10:00:00 3.1 0.7 4.9 1.5 3.3 0.8 4.9 1.5 3.2 0.7 4.9 1.5 114 11 104 165 1.5 0 1.8 1.4 04/02/2007 10:10:00 3.4 0.6 5.3 1.5 3.6 0.6 4.9 1.9 3.5 0.7 5.3 1.9 116 8 114 165 1.6 0 1.8 1.4 04/02/2007 10:20:00 3.6 0.4 5.3 2.3 3.8 0.4 5.3 2.3 3.7 0.5 4.9 2.3 113 5 113 165 1.6 0 1.8 1.6 04/02/2007 10:30:00 3.3 0.5 4.6 2.3 3.4 0.5 4.9 2.3 3.4 0.5 4.9 2.3 109 10 95 165 1.7 0 1.8 1.6 04/02/2007 10:40:00 3.8 0.7 5.7 1.9 4.1 0.8 6.1 2.3 4 0.7 5.7 2.3 106 7 106 165 1.7 0 1.8 1.6 04/02/2007 10:50:00 3.8 0.6 5.7 2.3 4.1 0.6 5.7 2.6 4.1 0.5 5.3 2.6 112 7 119 165 1.8 0 1.8 1.6 04/02/2007 11:00:00 3.8 0.6 5.7 2.6 4.2 0.6 6.1 2.6 4 0.6 5.7 2.6 109 9 113 165 1.7 0 1.8 1.6 04/02/2007 11:10:00 3.6 0.5 4.9 2.3 3.8 0.6 5.3 2.3 3.8 0.5 4.9 2.6 104 8 102 165 1.9 0 1.8 1.6 04/02/2007 11:20:00 4.1 0.6 5.7 2.6 4.4 0.7 6.1 2.6 4.2 0.6 5.7 2.6 117 10 112 165 1.8 0 2.1 1.6 04/02/2007 11:30:00 3.4 0.7 6.5 1.9 3.6 0.8 6.5 2.3 3.6 0.7 6.1 1.9 114 9 99 165 1.8 0 2.1 1.6 04/02/2007 11:40:00 3.1 0.6 4.9 1.5 3.3 0.6 4.6 1.9 3.3 0.6 4.6 1.5 114 11 111 165 1.9 0 2.3 1.8 04/02/2007 11:50:00 3.6 0.5 4.9 2.3 3.9 0.6 5.3 1.9 3.8 0.6 5.7 2.6 112 9 125 165 1.9 0 2.3 1.8 04/02/2007 12:00:00 4 0.6 5.3 2.3 4.3 0.6 6.1 2.3 4.3 0.6 5.7 3 118 8 122 165 2 0 2.3 1.8 04/02/2007 12:10:00 4.2 0.5 5.3 3 4.5 0.5 5.7 3 4.6 0.4 5.7 3.4 137 6 122 165 1.8 0 2.1 1.6 04/02/2007 12:20:00 4.5 0.4 5.7 3.8 4.8 0.4 6.1 3.8 4.8 0.4 6.1 3.8 138 3 132 165 1.7 0 1.8 1.6 04/02/2007 12:30:00 4.3 0.3 4.9 3.4 4.6 0.3 5.7 3.8 4.7 0.3 5.3 3.8 139 4 138 165 1.7 0 1.8 1.6 04/02/2007 12:40:00 3.8 0.5 5.3 2.6 4.1 0.5 5.7 3 4.2 0.5 5.3 2.6 139 10 163 165 2 0 2.3 1.8 04/02/2007 12:50:00 5.2 0.4 6.1 4.2 5.2 0.4 6.1 4.2 5.4 0.3 6.1 4.6 148 5 144 165 2 0.1 2.3 1.8 04/02/2007 13:00:00 5.1 0.5 6.1 4.2 5.2 0.5 6.1 4.2 5.1 0.4 6.1 3.8 138 3 138 165 1.8 0 1.8 1.6 04/02/2007 13:10:00 4.7 0.4 5.7 3.4 5 0.4 6.1 3.4 5 0.5 6.1 3.4 138 4 142 165 1.8 0 1.8 1.6 04/02/2007 13:20:00 5.1 0.3 6.1 4.2 5.5 0.3 6.1 4.9 5.5 0.4 6.5 4.2 137 3 135 165 1.6 0 1.8 1.6 04/02/2007 13:30:00 4.8 0.4 6.1 3.8 5.2 0.4 6.1 4.2 5.3 0.4 6.1 4.2 134 5 143 165 1.7 0 1.8 1.6 04/02/2007 13:40:00 6 0.5 6.8 4.2 6.3 0.5 7.2 4.6 6.4 0.5 7.2 4.9 137 4 135 165 1.7 0 1.8 1.6 04/02/2007 13:50:00 6.4 0.5 7.6 4.6 6.6 0.5 7.6 4.9 6.7 0.5 7.6 4.9 140 4 145 165 1.4 0.2 1.8 0.9 04/02/2007 14:00:00 6.1 0.5 7.2 4.6 6.4 0.5 7.2 4.9 6.4 0.5 7.2 4.9 140 4 138 165 1.3 0.1 1.6 0.9 04/02/2007 14:10:00 4.9 0.5 6.1 3.8 5.2 0.5 6.5 3.8 5.4 0.5 6.5 4.2 143 6 140 165 1.7 0 1.8 1.6 04/02/2007 14:20:00 4.6 0.5 6.1 3 4.9 0.5 6.1 3 4.9 0.5 5.7 3.4 139 6 138 165 1.7 0 1.8 1.6 04/02/2007 14:30:00 4.4 0.4 5.3 3 4.7 0.4 5.7 3.4 4.7 0.4 6.1 3.4 138 6 134 165 1.8 0 1.8 1.6 04/02/2007 14:40:00 4.4 0.4 5.7 3 4.7 0.4 5.7 3.4 4.8 0.4 5.7 4.2 141 5 135 165 1.8 0 1.8 1.6 04/02/2007 14:50:00 5.1 0.6 7.2 3.4 5.3 0.6 7.6 4.2 5.4 0.6 6.8 4.2 139 6 125 165 1.7 0 1.8 1.6 04/02/2007 15:00:00 5.2 0.6 6.5 3.4 5.5 0.6 6.8 3.8 5.5 0.6 6.8 3.8 133 6 128 165 1.8 0.1 2.1 1.6 04/02/2007 15:10:00 6.8 1.1 8.8 4.6 7 1 9.1 4.9 7 0.9 8.8 4.6 138 4 136 165 1.8 0 2.1 1.6 04/02/2007 15:20:00 6.7 0.7 8.8 4.6 7 0.6 8.8 5.3 7 0.7 8.8 4.6 137 7 132 165 1.7 0 1.8 1.6 04/02/2007 15:30:00 7 0.6 8.8 5.3 7.2 0.6 8.8 5.7 7.2 0.6 8.8 5.7 139 6 139 165 1.4 0.1 1.6 1.4 04/02/2007 15:40:00 7.8 0.7 9.1 5.7 8 0.6 9.1 6.1 7.9 0.7 9.1 6.1 137 4 128 165 1.4 0 1.6 1.4 04/02/2007 15:50:00 8.3 0.6 10.3 6.5 8.4 0.6 9.9 6.8 8.4 0.7 9.9 6.5 138 5 125 165 1.3 0 1.6 1.1 04/02/2007 16:00:00 7.3 0.7 9.1 5.3 7.6 0.7 9.5 5.3 7.5 0.8 9.9 5.3 138 5 125 165 1.2 0 1.4 1.1 04/02/2007 16:10:00 6.7 0.7 8.4 4.9 7.1 0.6 8.8 4.9 6.9 0.7 8.4 4.6 133 7 136 165 1.2 0 1.4 1.1 04/02/2007 16:20:00 6.9 0.6 8.8 5.3 7.2 0.6 8.8 5.7 7.2 0.6 9.1 5.3 138 6 144 165 1.2 0 1.4 1.1 04/02/2007 16:30:00 7.2 0.7 9.1 5.3 7.5 0.6 9.5 5.3 7.4 0.7 9.1 5.3 135 8 140 165 1.2 0 1.4 0.9 04/02/2007 16:40:00 8.7 0.8 10.3 6.1 8.8 0.7 10.3 6.5 8.9 0.8 10.7 5.7 143 4 143 165 1 0.2 1.6 0.7 04/02/2007 16:50:00 8.4 0.6 9.9 6.8 8.5 0.5 10.3 6.8 8.5 0.6 9.9 6.8 140 4 139 165 0.8 0 0.9 0.7 04/02/2007 17:00:00 7.8 0.8 9.5 5.7 8 0.7 9.5 5.7 7.9 0.7 9.9 6.1 135 6 138 165 0.6 0 0.9 0.2 04/02/2007 17:10:00 7.6 0.6 8.8 5.7 7.8 0.6 8.8 6.1 7.7 0.6 9.1 6.1 142 5 143 165 0.7 0 0.9 0.4 04/02/2007 17:20:00 6.4 0.6 7.6 5.3 6.7 0.6 8 5.3 6.7 0.6 8.8 5.3 143 4 143 165 0.6 0 0.9 0.4 04/02/2007 17:30:00 5.1 0.4 6.1 3.8 5.4 0.4 6.5 4.2 5.4 0.5 6.8 4.2 143 4 142 165 0.5 0 0.7 0.2 04/02/2007 17:40:00 5.3 0.6 6.8 4.2 5.6 0.6 7.2 4.6 5.5 0.6 6.8 4.2 138 5 138 165 0.4 0 0.7 0.2 04/02/2007 17:50:00 6.5 0.4 7.2 5.3 6.7 0.4 7.6 5.7 6.8 0.4 8 5.7 148 5 145 165 0.5 0 0.7 0.2 04/02/2007 18:00:00 5.3 0.5 6.5 3.4 5.6 0.5 6.8 3.8 5.6 0.6 6.8 3.8 151 5 143 165 0.4 0.1 0.7 0.2 04/02/2007 18:10:00 4.8 0.5 6.1 3.4 5 0.5 6.1 3.4 5 0.5 6.5 3.8 152 4 156 165 0.3 0.1 0.7 0.2 04/02/2007 18:20:00 4.1 0.5 5.3 2.6 4.3 0.5 5.3 3.4 4.2 0.5 5.3 3 147 6 136 165 0.2 0 0.4 0.2 04/02/2007 18:30:00 4.7 0.5 6.1 3.4 4.7 0.5 5.7 3.4 4.9 0.6 6.1 3 148 5 151 165 0.2 0 0.7 0.2 04/02/2007 18:40:00 4.9 0.6 6.5 3.8 5.1 0.5 6.1 3.8 5.1 0.7 6.5 3.4 142 6 151 165 0.2 0 0.4 0.2 04/02/2007 18:50:00 5 0.5 6.1 3.4 5.1 0.5 6.1 3.4 5.3 0.4 6.5 4.2 148 7 145 165 0.2 0 0.4 0.2 04/02/2007 19:00:00 4.9 0.5 6.1 3.8 5.1 0.5 6.5 3.8 5.2 0.5 6.1 3.8 148 5 153 165 0.2 0 0.7 0.2 04/02/2007 19:10:00 5.3 0.4 6.1 4.2 5.6 0.3 6.5 4.6 5.6 0.4 6.5 4.6 143 4 145 165 0.3 0 0.7 0.2 04/02/2007 19:20:00 5.6 0.3 6.5 4.6 5.9 0.4 6.8 4.9 6 0.4 6.8 4.9 144 3 145 165 0.3 0 0.7 0.2 04/02/2007 19:30:00 6 0.4 6.8 4.9 6.2 0.4 7.2 5.3 6.2 0.4 7.2 5.3 142 4 138 165 0.4 0 0.7 0.2 04/02/2007 19:40:00 5.6 0.4 6.8 4.6 5.9 0.4 7.2 4.9 6 0.5 7.2 4.6 144 4 135 165 0.5 0 0.7 0.2 04/02/2007 19:50:00 4.9 0.4 6.1 3.8 5.3 0.4 6.5 4.2 5.3 0.4 6.5 4.2 140 7 135 165 0.5 0 0.7 0.2 04/02/2007 20:00:00 5.6 0.3 6.5 4.9 5.8 0.4 6.8 4.6 5.9 0.4 6.8 4.6 135 4 138 165 0.5 0 0.7 0.2 04/02/2007 20:10:00 5.8 0.4 6.8 4.9 6.1 0.4 7.2 4.9 6.1 0.4 7.2 4.6 126 4 122 165 0.4 0 0.7 0.2 04/02/2007 20:20:00 6.5 0.5 8 4.9 6.8 0.5 8 5.3 6.8 0.5 8 5.3 124 4 122 165 0.4 0 0.7 0.2 04/02/2007 20:30:00 6.8 0.5 8.4 5.3 7.1 0.5 8.4 5.7 7.3 0.5 8.4 5.7 128 5 128 165 0.3 0 0.7 0.2 04/02/2007 20:40:00 6.7 0.6 8.4 5.3 6.9 0.5 8.4 5.3 7.1 0.6 8.4 5.3 137 6 143 165 0.3 0 0.7 0.2 04/02/2007 20:50:00 7.3 0.6 8.8 5.7 7.4 0.5 8.4 5.7 7.6 0.6 8.8 5.3 142 3 145 165 0.3 0 0.7 0.2 04/02/2007 21:00:00 6.4 0.4 8 5.3 6.7 0.4 8 5.7 6.7 0.5 8 5.3 139 5 139 165 0.2 0 0.4 0.2 04/02/2007 21:10:00 7 0.5 8.4 5.7 7.2 0.5 8.4 6.1 7.1 0.5 8.4 5.7 141 6 138 165 0.2 0 0.4 0.2 04/02/2007 21:20:00 6.5 0.4 7.6 5.3 6.8 0.4 8 5.7 6.8 0.4 8 5.7 141 3 133 165 0.3 0 0.7 0.2 04/02/2007 21:30:00 7 0.6 8.8 5.7 7.1 0.5 8.8 6.1 7.3 0.6 9.1 6.1 150 5 149 165 0.4 0.1 0.7 0.2 04/02/2007 21:40:00 6 0.3 6.8 5.3 6.3 0.3 7.2 5.3 6.5 0.3 7.2 5.7 145 3 143 165 0.3 0 0.7 0.2 04/02/2007 21:50:00 6.2 0.6 7.6 4.6 6.5 0.5 7.6 4.9 6.5 0.6 8 4.9 141 5 148 165 0.3 0 0.7 0.2 04/02/2007 22:00:00 6.6 0.5 8 5.3 6.9 0.5 8 5.7 6.9 0.6 8.4 5.3 143 5 147 165 0.4 0 0.7 0.2 04/02/2007 22:10:00 6.5 0.4 7.6 5.7 6.8 0.4 8 5.7 6.8 0.5 8 5.3 142 5 129 165 0.4 0 0.7 0.2 04/02/2007 22:20:00 7.3 0.8 8.8 5.7 7.4 0.6 8.8 6.1 7.5 0.7 8.8 5.7 146 5 150 165 0.5 0 0.7 0.2 04/02/2007 22:30:00 8.4 0.6 9.9 6.8 8.5 0.5 9.9 7.2 8.5 0.5 10.3 6.8 146 4 141 165 0.5 0 0.7 0.4 04/02/2007 22:40:00 9.1 0.5 10.3 7.6 9.2 0.5 10.3 8 9.2 0.5 10.3 7.2 145 3 145 165 0.5 0 0.7 0.2 04/02/2007 22:50:00 8.8 0.4 9.9 7.2 8.9 0.4 9.9 7.6 8.9 0.5 9.9 7.2 149 3 148 165 0.5 0 0.9 0.2 04/02/2007 23:00:00 7.7 0.6 8.8 5.3 7.9 0.5 8.8 5.7 7.8 0.6 8.8 6.1 143 4 147 165 0.5 0 0.7 0.4 04/02/2007 23:10:00 7.6 0.6 9.1 5.7 7.8 0.5 9.1 6.1 7.8 0.5 9.1 5.3 142 4 136 165 0.5 0 0.7 0.2 04/02/2007 23:20:00 8.4 0.5 9.1 6.5 8.4 0.5 9.5 7.2 8.4 0.5 9.5 6.5 138 4 136 165 0.4 0 0.7 0.2 04/02/2007 23:30:00 7.6 0.6 9.1 5.7 7.8 0.5 9.1 5.7 7.7 0.6 9.1 5.7 130 5 133 165 0.1 0 0.4 -0.3 04/02/2007 23:40:00 7.1 0.7 9.1 4.9 7.4 0.6 9.1 5.3 7.3 0.7 9.1 4.9 133 6 139 165 0.1 0 0.2 -0.1 04/02/2007 23:50:00 7.2 1 9.1 4.6 7.4 0.9 9.1 4.9 7.3 0.8 9.1 5.3 138 5 136 165 0.2 0 0.2 -0.1 04/03/2007 00:00:00 6.6 0.7 8.8 4.6 6.9 0.6 8.8 4.9 6.8 0.7 8.4 4.9 139 6 142 165 0.2 0 0.7 0.2 04/03/2007 00:10:00 6.4 0.6 8 4.9 6.8 0.6 8.4 5.3 6.6 0.6 8 4.6 135 7 126 165 0.3 0 0.7 0.2 04/03/2007 00:20:00 6.6 0.5 8 4.9 7 0.5 8.4 5.3 6.8 0.6 8.8 4.6 133 5 144 165 0.4 0 0.7 0.2 04/03/2007 00:30:00 6.9 0.7 9.1 4.9 7.2 0.6 8.8 5.7 7 0.7 9.1 4.9 137 6 136 165 0.4 0 0.7 0.2 04/03/2007 00:40:00 6.4 0.6 8 4.6 6.8 0.6 8 4.9 6.7 0.8 8.8 4.6 139 6 141 165 0.5 0 0.7 0.2 04/03/2007 00:50:00 6.7 0.7 8.4 4.9 7 0.6 8 5.3 7.1 0.6 8.4 5.3 142 4 151 165 0.5 0 0.7 0.2 04/03/2007 01:00:00 7.2 0.5 8.8 6.1 7.4 0.5 8.8 6.5 7.5 0.5 8.8 6.1 142 4 139 165 0.7 0 0.9 0.4 04/03/2007 01:10:00 8 0.7 9.1 5.7 8 0.6 9.1 5.7 8 0.8 9.5 4.9 140 5 145 165 0.5 0 0.7 0.2 04/03/2007 01:20:00 6.5 0.5 8 5.3 6.8 0.5 8.4 5.7 6.7 0.6 8 5.3 140 4 144 165 0.1 0 0.4 -0.1 04/03/2007 01:30:00 5.8 0.5 6.8 4.2 6.1 0.5 7.2 4.2 6 0.5 7.2 4.6 135 5 143 165 0.1 0 0.2 -0.1 04/03/2007 01:40:00 4.9 0.7 6.8 3.4 5.3 0.7 6.8 3.4 5.4 0.7 6.8 3.4 137 7 137 165 0.2 0 0.4 0.2 04/03/2007 01:50:00 4.8 0.5 5.7 3.4 5.1 0.5 6.1 3.8 5.2 0.5 6.5 3.8 137 7 140 165 0.2 0 0.4 -0.1 04/03/2007 02:00:00 6.8 1.6 9.5 4.6 7 1.5 9.5 4.6 7.1 1.5 9.9 4.6 143 6 147 165 0.2 0 0.4 -0.1 04/03/2007 02:10:00 8.1 0.6 9.1 6.5 8.1 0.5 9.1 6.5 8.3 0.5 9.1 6.5 145 4 154 165 0.2 0 0.7 0.2 04/03/2007 02:20:00 6.8 1.3 9.1 4.6 7 1.1 8.8 4.9 7.2 1.2 9.5 4.9 142 3 145 165 0.2 0 0.2 -0.1 04/03/2007 02:30:00 5.4 0.5 6.8 3.4 5.8 0.6 6.8 3.8 5.8 0.6 7.2 3.8 138 0 138 165 0.1 0 0.2 -0.1 04/03/2007 02:40:00 4.9 0.4 5.7 3.8 5.4 0.4 6.5 4.2 5.2 0.4 6.5 3.8 138 0 138 165 0.1 0 0.2 -0.1 04/03/2007 02:50:00 5 0.3 5.7 3.8 5.6 0.3 6.1 4.6 5.4 0.4 6.1 3.8 138 0 137 165 -0.1 0 -0.1 -0.3 04/03/2007 03:00:00 5.5 0.7 7.2 3.8 6.1 0.8 7.6 3.8 5.9 0.7 7.6 3.8 138 0 138 165 -0.2 0 -0.1 -0.3 04/03/2007 03:10:00 6.3 0.5 7.6 4.9 6.8 0.5 8 5.7 6.6 0.6 8 4.6 138 0 138 165 0.1 0.1 0.2 -0.3 04/03/2007 03:20:00 6.3 0.6 8 4.2 6.8 0.6 8 4.6 6.4 0.7 8 4.6 138 0 138 165 0.2 0 0.2 -0.1 04/03/2007 03:30:00 7.2 1.1 9.9 5.3 7.6 1 9.9 5.7 7.4 1 9.5 4.9 137 0 137 165 0.2 0 0.4 -0.1 04/03/2007 03:40:00 7.8 1.1 10.3 4.6 8 1 10.7 5.3 7.9 1.2 10.7 4.6 129 8 116 165 0.2 0 0.4 -0.1 04/03/2007 03:50:00 6.8 0.6 9.1 4.9 7.2 0.5 9.1 5.7 7.2 0.5 9.5 5.3 123 3 121 165 0.1 0 0.2 -0.1 04/03/2007 04:00:00 7.8 0.6 9.5 6.1 8.1 0.5 9.5 6.5 8.1 0.6 9.9 6.5 126 5 119 165 0.1 0 0.2 -0.1 04/03/2007 04:10:00 6.9 0.9 8.8 4.9 7.3 0.7 9.1 5.7 7.2 0.8 9.1 5.7 123 4 128 165 0.1 0 0.2 -0.1 04/03/2007 04:20:00 6.5 0.9 8.8 4.6 7 0.7 9.1 5.3 7 0.8 9.1 4.9 121 6 129 165 0 0 0.2 -0.1 04/03/2007 04:30:00 6.7 0.7 8.4 4.9 7.2 0.6 8.4 5.7 7.1 0.5 8.8 5.3 126 5 126 165 0.2 0 0.4 -0.1 04/03/2007 04:40:00 6.7 0.6 8.4 4.9 7.2 0.5 8.8 5.7 7.2 0.5 9.1 5.7 123 5 116 165 0.2 0 0.4 0.2 04/03/2007 04:50:00 7.2 0.7 8.8 4.9 7.6 0.6 8.8 6.1 7.5 0.7 8.8 5.7 119 5 119 165 0.2 0 0.7 -0.1 04/03/2007 05:00:00 6.9 0.9 8.8 4.6 7.4 0.8 8.8 4.9 7.2 0.8 8.8 4.9 117 5 121 165 0 0 0.2 -0.3 04/03/2007 05:10:00 6.7 0.7 8.4 4.6 7.2 0.7 8.8 4.9 6.8 0.8 9.1 4.2 117 5 122 165 -0.2 0.1 0.2 -0.3 04/03/2007 05:20:00 6.5 0.8 8.8 4.6 6.9 0.8 9.1 4.9 6.7 0.8 8.8 4.2 123 8 119 165 -0.3 0 -0.1 -0.5 04/03/2007 05:30:00 6.5 0.6 8.4 4.9 6.9 0.5 8.4 5.3 7 0.6 8.8 5.7 126 6 121 165 -0.3 0 -0.1 -0.5 04/03/2007 05:40:00 6.6 0.6 8 4.9 7 0.5 8.4 5.7 6.9 0.6 8.4 4.9 120 5 134 165 -0.2 0 -0.1 -0.3 04/03/2007 05:50:00 6.9 0.6 8.4 4.9 7.4 0.5 8.8 5.7 7.1 0.7 8.8 4.9 112 4 116 165 -0.1 0 0.2 -0.3 04/03/2007 06:00:00 7.1 0.7 9.1 4.2 7.7 0.6 9.1 5.3 7.2 0.7 9.1 4.9 103 4 107 165 -0.1 0 0.2 -0.3 04/03/2007 06:10:00 7.9 0.5 9.1 5.7 8.4 0.4 9.5 6.5 8 0.8 9.1 5.7 112 9 122 165 -0.3 0 -0.1 -0.5 04/03/2007 06:20:00 8.2 0.7 10.3 5.7 8.5 0.7 11.1 5.3 8.5 0.8 9.9 6.1 128 6 121 165 -0.2 0 -0.1 -0.3 04/03/2007 06:30:00 6.8 0.7 8.8 5.3 7.2 0.6 9.5 5.7 7.4 0.6 9.1 5.7 125 5 119 165 -0.1 0 0.2 -0.3 04/03/2007 06:40:00 7.8 0.8 9.5 5.3 8.1 0.7 9.5 6.1 8.3 0.7 9.9 6.1 128 5 128 165 0 0 0.2 -0.1 04/03/2007 06:50:00 6.4 0.6 8 4.6 6.9 0.6 8 4.9 6.9 0.6 8 5.3 128 5 137 165 0.1 0 0.2 -0.1 04/03/2007 07:00:00 7.1 0.6 8.8 5.7 7.5 0.5 8.8 6.5 7.2 0.6 8.8 5.3 119 5 118 165 0.1 0 0.2 -0.1 04/03/2007 07:10:00 8 0.8 10.3 5.7 8.2 0.7 10.7 6.1 8.2 0.8 9.9 5.7 122 6 125 165 0.1 0 0.2 -0.1 04/03/2007 07:20:00 9 1 11.5 6.5 9.2 0.9 11.8 7.2 9.4 1 11.5 6.8 137 7 131 165 0.1 0 0.2 -0.1 04/03/2007 07:30:00 10.1 0.9 12.2 8 10.3 0.8 12.2 8.4 10.4 1 12.2 7.6 137 4 136 165 -0.1 0 0.2 -0.3 04/03/2007 07:40:00 9.4 1 11.5 7.2 9.6 1 11.8 7.2 9.5 1.1 11.8 6.5 137 5 145 165 -0.3 0 -0.1 -0.5 04/03/2007 07:50:00 7.7 0.7 9.1 5.3 8 0.7 9.1 6.1 7.6 0.8 9.5 5.3 131 5 133 165 -0.2 0 -0.1 -0.3 04/03/2007 08:00:00 8.1 0.9 9.5 4.9 8.3 0.8 9.9 4.9 8.3 0.9 10.3 4.6 124 5 127 165 -0.1 0 -0.1 -0.3 04/03/2007 08:10:00 7.5 0.6 9.1 5.7 7.8 0.5 9.1 6.5 7.6 0.7 9.5 6.1 121 5 129 165 -0.1 0 0.2 -0.3 04/03/2007 08:20:00 7.4 0.6 9.1 5.7 7.8 0.5 9.1 6.5 7.7 0.6 9.5 6.1 121 4 121 165 0 0 0.2 -0.1 04/03/2007 08:30:00 8 0.7 9.5 5.3 8.4 0.6 10.3 6.1 8.3 0.7 9.9 6.1 121 5 118 165 -0.1 0 0.2 -0.3 04/03/2007 08:40:00 8.5 1 11.1 6.1 8.9 0.9 11.1 6.8 8.5 0.9 11.1 6.5 121 6 121 165 -0.1 0 0.2 -0.3 04/03/2007 08:50:00 9.9 1.2 13 7.2 10.2 1.2 13.3 7.6 10.1 1.2 13.7 7.2 123 6 121 165 -0.2 0 -0.1 -0.3 04/03/2007 09:00:00 7.3 1 10.7 4.6 7.7 1 10.7 5.3 7.2 1.2 10.3 4.2 119 4 124 165 -0.3 0 -0.1 -0.5 04/03/2007 09:10:00 7.2 1 9.9 4.9 7.7 1 9.9 5.7 7.3 1 9.9 4.9 118 5 121 165 -0.1 0 0.2 -0.3 04/03/2007 09:20:00 6.5 0.8 8.4 4.2 7.1 0.7 8.4 4.9 6.5 0.8 8 4.2 114 5 117 165 0 0 0.2 -0.1 04/03/2007 09:30:00 6.4 0.8 8.8 4.2 6.9 0.7 9.1 4.6 6.5 0.7 8 4.6 117 5 121 165 0.1 0 0.2 -0.1 04/03/2007 09:40:00 7.2 1 9.9 4.6 7.7 0.8 10.3 5.3 7.4 0.9 9.5 4.6 117 5 118 165 0.1 0 0.2 -0.1 04/03/2007 09:50:00 6.4 1.2 9.1 3.8 6.9 1.1 9.1 4.6 6.3 1 9.1 3.8 115 7 107 165 0.2 0 0.4 0.2 04/03/2007 10:00:00 8.7 0.9 11.1 6.5 9 0.8 11.1 6.8 8.8 1 11.1 6.1 120 6 121 165 0.2 0 0.7 0.2 04/03/2007 10:10:00 8.2 1 10.3 5.3 8.5 1 10.3 6.1 8.4 1 10.7 5.7 121 4 128 165 0.2 0 0.4 0.2 04/03/2007 10:20:00 7.5 0.9 9.5 4.9 7.9 0.8 10.3 5.7 7.5 0.9 9.9 4.6 115 6 116 165 0.2 0 0.4 0.2 04/03/2007 10:30:00 8.2 1 10.7 6.1 8.5 1 11.1 6.5 8 1 10.3 5.7 114 7 112 165 0.3 0 0.7 0.2 04/03/2007 10:40:00 7.6 1.2 9.9 4.6 8.1 1.2 10.3 4.9 7.5 1.2 10.3 3.8 112 6 115 165 0.4 0 0.7 0.2 04/03/2007 10:50:00 8.2 0.7 9.9 4.6 8.5 0.8 10.7 4.9 7.8 0.9 9.9 4.9 113 5 111 165 0.4 0 0.7 0.2 04/03/2007 11:00:00 8.3 0.9 10.3 5.3 8.5 0.9 11.1 6.1 7.9 0.9 9.9 5.7 116 5 126 165 0.5 0 0.7 0.2 04/03/2007 11:10:00 8.7 0.8 10.3 6.5 8.9 0.9 10.7 6.1 8.2 1 11.1 5.3 108 6 102 165 0.5 0 0.7 0.4 04/03/2007 11:20:00 7.8 0.8 9.9 5.7 8 0.8 9.9 6.1 7.5 0.8 9.9 5.7 107 6 111 165 0.4 0 0.7 0.2 04/03/2007 11:30:00 6.2 1.2 8.4 3.8 6.5 1.1 8.8 4.2 6.1 1.2 8.8 2.6 115 6 113 165 0.2 0 0.7 -0.1 04/03/2007 11:40:00 6.6 1.1 9.1 2.6 7 1 9.5 4.2 6.6 1 9.1 4.2 110 7 105 165 0.3 0 0.7 0.2 04/03/2007 11:50:00 6.8 1.1 9.1 3.8 7.1 1 9.5 4.2 6.5 1 8.8 4.6 111 8 107 165 0.5 0 0.7 0.2 04/03/2007 12:00:00 7.4 1 10.3 4.6 7.6 1 10.7 4.9 7.1 1 9.9 4.6 109 7 104 165 0.7 0 0.9 0.7 04/03/2007 12:10:00 8.2 1.4 10.7 4.9 8.5 1.4 10.7 5.3 7.9 1.4 10.7 4.6 105 7 99 165 0.7 0 0.9 0.4 04/03/2007 12:20:00 8.6 0.8 10.3 6.1 8.8 0.8 10.3 6.5 8.2 0.9 10.3 5.7 96 6 98 165 0.6 0 0.9 0.7 04/03/2007 12:30:00 8.9 0.9 11.1 5.7 9.2 1 11.5 5.7 8.6 1 11.1 6.1 94 6 99 165 0.7 0 0.9 0.4 04/03/2007 12:40:00 7.7 0.8 10.3 5.3 7.9 0.9 10.3 5.3 7.4 1 9.9 5.3 93 7 92 165 0.8 0 0.9 0.7 04/03/2007 12:50:00 8.1 1.1 10.7 5.3 8.4 1.2 10.7 5.3 8.1 1.2 10.7 5.3 91 6 88 165 0.8 0 0.9 0.7 04/03/2007 13:00:00 8.1 1 9.9 5.3 8.4 1 10.3 5.3 7.9 1 9.9 5.3 95 7 94 165 0.8 0 0.9 0.7 04/03/2007 13:10:00 7.4 0.8 9.1 4.9 7.7 0.9 9.5 4.9 7.3 0.8 9.1 5.7 93 6 91 165 0.8 0 0.9 0.7 04/03/2007 13:20:00 7.1 0.9 9.5 4.9 7.4 0.9 9.5 5.3 7 1 9.5 4.6 92 9 97 165 0.8 0 1.1 0.7 04/03/2007 13:30:00 7 1 9.1 4.2 7.3 1 9.5 4.2 6.8 1 8.8 3.8 95 8 88 165 0.8 0 1.1 0.7 04/03/2007 13:40:00 7.9 1.2 10.3 4.6 8.3 1.3 11.1 5.3 7.8 1.2 10.3 4.6 88 6 85 165 1 0 1.4 0.9 04/03/2007 13:50:00 8.6 0.8 10.3 6.1 8.9 0.9 10.7 6.5 8.4 0.8 10.3 6.5 87 5 89 165 1 0 1.4 0.9 04/03/2007 14:00:00 8.6 0.8 10.3 6.1 8.9 0.9 10.7 5.7 8.4 0.9 10.3 5.3 86 5 83 165 1.1 0 1.4 0.9 04/03/2007 14:10:00 7.7 1.1 9.9 4.9 8 1.1 10.3 4.9 7.5 1 10.3 4.9 90 8 88 165 1.1 0 1.4 0.9 04/03/2007 14:20:00 8.5 1 11.1 6.1 8.8 1 11.5 6.1 8.4 1 11.1 6.1 91 8 98 165 1.2 0 1.4 0.9 04/03/2007 14:30:00 8.2 0.8 10.3 5.3 8.7 0.9 10.7 5.7 8.3 0.8 10.3 5.7 85 6 83 165 1 0 1.4 0.9 04/03/2007 14:40:00 8 1.1 10.7 5.3 8.4 1.1 11.1 5.7 8.1 1 10.7 5.7 84 7 88 165 1 0 1.1 0.9 04/03/2007 14:50:00 8 0.9 10.3 5.3 8.4 1 10.7 5.3 7.9 0.9 10.7 5.7 89 8 88 165 1 0 1.1 0.9 04/03/2007 15:00:00 8.5 0.8 10.3 6.1 8.8 0.9 10.7 6.5 8.2 0.9 10.7 5.7 97 6 99 165 0.9 0 1.4 0.9 04/03/2007 15:10:00 8.8 0.8 10.7 6.1 9.2 0.8 11.1 6.8 8.6 0.9 10.3 6.1 96 5 92 165 0.9 0 1.4 0.9 04/03/2007 15:20:00 8.7 0.7 10.3 6.5 9.1 0.8 10.7 6.5 8.4 0.8 10.3 6.5 95 7 87 165 1.2 0.1 1.6 0.9 04/03/2007 15:30:00 9 0.8 10.7 6.8 9.4 0.8 11.1 7.2 8.8 0.8 10.7 6.5 96 5 98 165 1.5 0 1.8 1.4 04/03/2007 15:40:00 8.6 0.9 10.3 6.5 8.9 0.9 10.7 6.5 8.3 0.9 10.3 6.1 96 6 99 165 1.5 0 1.8 1.4 04/03/2007 15:50:00 9 0.9 11.5 6.5 9.3 1 11.8 6.8 8.7 1 11.5 6.1 96 6 98 165 1.4 0 1.6 1.4 04/03/2007 16:00:00 8.4 0.9 10.3 6.1 8.7 1 10.7 6.1 8.1 1 10.3 5.3 92 7 100 165 1.5 0 1.8 1.4 04/03/2007 16:10:00 8.9 0.9 10.7 6.1 9.3 0.9 11.1 6.5 8.6 1 10.7 6.1 94 6 92 165 1.4 0.1 1.8 1.4 04/03/2007 16:20:00 8.9 1 11.5 4.9 9.3 1 11.8 6.1 8.7 1 11.5 6.1 88 6 81 165 1.4 0 1.6 1.4 04/03/2007 16:30:00 9.6 0.9 11.5 6.5 10 1 12.6 6.8 9.5 0.9 11.5 7.2 89 5 96 165 1.5 0 1.8 1.4 04/03/2007 16:40:00 9.8 1.1 12.2 6.1 10.2 1.1 13 6.8 9.5 1.1 12.2 6.5 94 6 100 165 1.5 0 1.6 1.4 04/03/2007 16:50:00 9.2 1 11.8 6.8 9.6 1 12.6 7.2 9.2 1 12.2 6.5 90 7 104 165 1.5 0 1.8 1.4 04/03/2007 17:00:00 9.6 0.8 11.5 7.2 9.9 0.9 11.8 7.2 9.4 1 11.5 6.5 90 5 87 165 1.4 0 1.8 1.4 04/03/2007 17:10:00 8.6 1 11.1 6.1 9 1 11.5 6.8 8.6 0.9 11.5 6.5 86 5 96 165 1.4 0 1.6 1.4 04/03/2007 17:20:00 8.7 1.2 12.2 5.7 9.1 1.2 12.2 6.5 8.7 1.2 11.8 6.1 85 6 90 165 1.4 0 1.6 1.4 04/03/2007 17:30:00 8.7 1.1 13 5.3 9.2 1.1 13.3 6.5 8.7 1.2 13.7 6.5 84 7 99 165 1.3 0 1.4 1.1 04/03/2007 17:40:00 10.5 1.6 14.1 6.5 10.8 1.7 14.5 6.5 10.2 1.6 14.1 6.1 91 7 91 165 1.1 0 1.4 0.9 04/03/2007 17:50:00 11.1 1 13.3 8 11.5 1 13.7 8 10.7 1 13 7.6 93 6 91 165 1.1 0 1.4 0.9 04/03/2007 18:00:00 10 1.3 13.3 6.8 10.3 1.3 13.7 7.2 9.8 1.3 12.6 6.8 83 9 98 165 1.2 0 1.4 0.9 04/03/2007 18:10:00 10.7 1 12.6 7.6 11.1 1 13.3 8.4 10.3 1 12.6 8 87 7 84 165 1 0 1.4 0.9 04/03/2007 18:20:00 10.7 0.9 12.2 8.4 11.1 0.9 13 8.4 10.4 0.9 12.6 7.6 89 5 88 165 1.2 0 1.4 0.9 04/03/2007 18:30:00 9.7 1 11.8 6.5 10.1 1 12.6 6.8 9.5 1 12.2 6.8 80 6 87 165 1.1 0 1.4 0.9 04/03/2007 18:40:00 9.8 1.2 12.6 6.5 10.2 1.2 13 7.2 9.6 1.3 12.2 6.8 79 6 80 165 1.2 0 1.4 0.9 04/03/2007 18:50:00 9 1.3 12.2 6.5 9.4 1.3 12.2 6.5 8.8 1.1 11.8 6.1 82 6 81 165 1.1 0 1.4 0.9 04/03/2007 19:00:00 10.2 1.2 13 6.5 10.6 1.2 13.3 6.5 10 1.1 12.6 6.1 86 6 87 165 1.2 0 1.4 0.9 04/03/2007 19:10:00 9.6 1.2 12.6 6.5 10 1.2 13 7.2 9.4 1.1 12.2 6.8 87 6 84 165 1.2 0 1.4 1.1 04/03/2007 19:20:00 10 1 12.2 7.2 10.4 1 12.6 7.6 9.8 1 11.8 7.6 88 6 91 165 1.2 0 1.4 1.1 04/03/2007 19:30:00 9.7 1.2 13 6.8 10.2 1.2 13.3 7.6 9.4 1.2 12.6 6.5 85 6 85 165 1.2 0 1.4 1.1 04/03/2007 19:40:00 10 1.2 12.2 6.5 10.4 1.2 13 6.8 9.9 1.2 13 6.1 88 6 94 165 1.2 0 1.4 1.1 04/03/2007 19:50:00 10.8 1.3 14.1 7.2 11.2 1.3 14.5 7.6 10.5 1.2 13.7 8 91 7 94 165 1.2 0 1.4 1.1 04/03/2007 20:00:00 11.2 1 13.3 8.4 11.6 1 13.7 8.8 10.8 1.1 13.3 8 95 6 103 165 1.3 0 1.4 1.1 04/03/2007 20:10:00 11.1 1.1 13.3 7.2 11.5 1.1 14.1 7.6 10.7 1.2 14.1 6.8 96 6 99 165 1.3 0 1.4 1.1 04/03/2007 20:20:00 11.2 1 13.7 8 11.6 1.1 14.1 8.4 10.6 1.1 13.3 7.6 98 6 102 165 1.2 0 1.4 1.1 04/03/2007 20:30:00 10.2 1.2 13 6.5 10.6 1.2 13.3 6.8 10 1.1 12.6 7.2 92 6 94 165 1.2 0 1.4 0.9 04/03/2007 20:40:00 10.4 1 12.6 7.2 10.8 1 13 8 10.1 1 13 7.6 90 6 89 165 1.2 0 1.4 0.9 04/03/2007 20:50:00 10.4 1.2 13 7.2 10.8 1.2 13.3 7.6 10.1 1.2 13 7.2 87 6 87 165 1.1 0 1.4 0.9 04/03/2007 21:00:00 10.7 1.2 13.7 7.2 11.2 1.2 14.5 7.2 10.6 1.2 13.3 7.2 87 5 81 165 1.1 0 1.4 0.9 04/03/2007 21:10:00 11.2 1.3 14.1 7.6 11.6 1.3 14.1 8 10.8 1.3 13.3 8 94 6 99 165 1.2 0 1.4 0.9 04/03/2007 21:20:00 12 1.4 16.1 8.4 12.4 1.4 16.1 8.8 11.5 1.3 14.9 7.6 95 7 99 165 1.1 0 1.4 0.9 04/03/2007 21:30:00 11.7 1.2 14.1 7.6 12.1 1.2 14.5 8 11.2 1.2 14.1 7.2 96 6 102 165 1.1 0 1.4 0.9 04/03/2007 21:40:00 11.1 1 13.3 7.2 11.4 1 13.3 8 10.5 1.1 14.5 7.6 97 6 102 165 1.2 0 1.4 0.9 04/03/2007 21:50:00 9.9 1 12.2 6.8 10.3 1 12.6 7.6 9.6 1 12.2 7.2 91 6 99 165 1.2 0 1.4 0.9 04/03/2007 22:00:00 10.3 1.2 13.3 7.2 10.7 1.2 13.7 7.6 9.9 1.3 13 6.8 87 6 85 165 1.2 0 1.4 0.9 04/03/2007 22:10:00 11.1 1.4 14.5 7.6 11.4 1.4 14.9 8 10.5 1.3 13.3 7.2 91 8 102 165 1.2 0 1.4 0.9 04/03/2007 22:20:00 11.5 1.3 14.9 7.6 11.9 1.4 15.6 8 11 1.4 14.1 7.2 96 6 94 165 1.2 0 1.4 0.9 04/03/2007 22:30:00 11.2 1.4 14.5 7.2 11.5 1.4 14.9 7.6 10.8 1.4 14.5 7.2 92 7 91 165 1.1 0 1.4 0.9 04/03/2007 22:40:00 13 1.3 16.1 9.5 13.4 1.4 16.1 9.1 12.4 1.4 15.6 8.8 93 6 79 165 0.9 0 1.1 0.9 04/03/2007 22:50:00 12 1.3 14.5 8.4 12.4 1.3 14.9 8.8 11.5 1.3 14.5 8 93 7 102 165 1 0 1.4 0.9 04/03/2007 23:00:00 12 1.3 14.5 8 12.4 1.4 15.3 8.4 11.6 1.3 14.1 8 89 6 90 165 1.1 0 1.4 0.9 04/03/2007 23:10:00 11.7 1.7 15.6 7.6 12 1.7 16.4 8 11.1 1.6 15.3 6.8 89 7 87 165 1.1 0 1.4 0.9 04/03/2007 23:20:00 11.5 1.3 14.1 8 11.9 1.3 14.9 8.4 11.2 1.3 14.1 8 89 7 91 165 1.1 0 1.4 0.9 04/03/2007 23:30:00 11.8 1.2 15.3 8.4 12.2 1.2 15.6 9.1 11.4 1.1 14.1 8 86 6 81 165 1.1 0 1.4 0.9 04/03/2007 23:40:00 11.2 1.2 13.7 8 11.6 1.2 14.5 8 10.9 1.2 13.7 8 85 6 85 165 1 0 1.4 0.9 04/03/2007 23:50:00 11.1 1.7 14.5 7.2 11.5 1.7 14.9 7.6 10.7 1.5 14.5 7.2 86 7 85 165 1 0 1.1 0.9 04/04/2007 00:00:00 11 1.5 14.5 7.2 11.4 1.5 14.9 7.6 10.6 1.5 14.9 7.2 89 7 93 165 0.9 0 1.1 0.9 04/04/2007 00:10:00 10.7 1.1 13.7 8 11.1 1.1 13.7 8.8 10.5 1.2 13.3 7.6 87 7 85 165 0.8 0 1.1 0.7 04/04/2007 00:20:00 12.8 1.3 15.3 8 13.1 1.3 15.6 8.8 12.2 1.3 14.9 9.1 88 8 88 165 0.7 0 0.9 0.4 04/04/2007 00:30:00 11.7 1.3 14.1 8.8 12.1 1.3 14.5 8.8 11.3 1.3 14.9 8.4 87 6 95 165 0.6 0 0.9 0.4 04/04/2007 00:40:00 11.3 1.2 14.1 8.4 11.7 1.2 14.9 8.8 10.9 1.1 13.7 8.8 88 6 88 165 0.7 0 0.9 0.7 04/04/2007 00:50:00 11.4 1.4 14.9 7.6 11.7 1.4 15.6 8.4 10.9 1.3 14.5 7.6 87 6 87 165 0.6 0 0.9 0.4 04/04/2007 01:00:00 10.7 1.4 14.5 7.6 11.1 1.4 14.5 8 10.6 1.3 13.7 7.6 84 7 94 165 0.6 0 0.9 0.4 04/04/2007 01:10:00 12.2 1.5 15.6 8.8 12.6 1.5 15.6 8.8 11.9 1.4 15.3 8.4 86 6 84 165 0.7 0 0.9 0.4 04/04/2007 01:20:00 10.2 1.2 14.1 6.8 10.6 1.2 14.9 7.2 10 1.3 14.1 6.8 85 6 91 165 0.4 0.1 0.9 0.2 04/04/2007 01:30:00 9.2 1.2 11.8 6.1 9.5 1.2 12.2 6.8 9.1 1.2 12.6 6.5 78 7 78 165 0.5 0 0.7 0.2 04/04/2007 01:40:00 10.1 1.6 13.3 6.1 10.5 1.6 13.7 6.8 9.9 1.5 13 6.5 77 8 74 165 0.7 0 0.9 0.7 04/04/2007 01:50:00 10 1.3 13.3 6.8 10.3 1.3 14.1 6.8 9.8 1.3 13.3 7.2 70 8 71 165 0.7 0 0.9 0.7 04/04/2007 02:00:00 9.5 1.3 12.2 5.3 9.9 1.3 13 5.7 9.4 1.2 12.6 5.7 69 8 68 165 0.7 0 0.9 0.7 04/04/2007 02:10:00 9.6 1.3 13 4.9 9.9 1.3 13 5.3 9.5 1.2 13 6.5 70 8 68 165 0.8 0 0.9 0.7 04/04/2007 02:20:00 10 1.5 14.1 6.8 10.4 1.5 14.5 6.8 9.9 1.5 14.1 6.5 73 7 58 165 0.8 0 0.9 0.7 04/04/2007 02:30:00 9.8 1.6 14.9 6.1 10.2 1.6 14.9 6.5 9.7 1.4 13 6.1 79 8 75 165 0.8 0 0.9 0.7 04/04/2007 02:40:00 8.9 1.2 13 5.7 9.2 1.2 13.3 6.1 8.8 1.2 13 5.7 78 8 69 165 0.7 0 0.9 0.7 04/04/2007 02:50:00 8.9 1.3 12.2 6.1 9.3 1.3 12.6 6.1 8.8 1.2 12.6 6.1 94 9 84 165 0.5 0 0.9 0.4 04/04/2007 03:00:00 10.2 2.3 15.6 4.9 10.5 2.3 16.1 5.7 9.9 2.1 15.3 5.7 86 8 86 165 0.5 0 0.7 0.4 04/04/2007 03:10:00 10.2 2.2 16.1 5.3 10.5 2.2 16.4 6.1 10 1.9 15.6 6.1 81 7 87 165 0.5 0 0.7 0.4 04/04/2007 03:20:00 10.8 1.6 14.9 7.6 11.2 1.7 15.3 8 10.6 1.7 14.9 7.2 78 8 84 165 0.7 0 0.9 0.7 04/04/2007 03:30:00 11.1 1.5 15.3 7.2 11.4 1.5 15.3 6.8 10.9 1.5 14.5 7.6 70 9 65 165 0.8 0 0.9 0.7 04/04/2007 03:40:00 10.5 1.6 14.5 6.5 10.8 1.6 14.9 7.2 10.4 1.3 13.3 6.8 74 8 78 165 0.7 0 0.9 0.4 04/04/2007 03:50:00 11.2 1.7 15.3 7.2 11.6 1.6 15.3 7.6 11 1.5 14.1 7.2 77 7 76 165 0.7 0 0.9 0.7 04/04/2007 04:00:00 10.6 1.2 14.1 7.2 10.9 1.2 14.1 7.6 10.4 1.2 13.7 7.6 73 8 84 165 0.7 0 0.9 0.7 04/04/2007 04:10:00 10.9 1.8 15.3 5.3 11.2 1.8 15.3 6.5 10.8 1.7 14.9 6.5 78 7 77 165 0.8 0 0.9 0.7 04/04/2007 04:20:00 10.4 1.7 15.3 7.2 10.7 1.7 15.6 7.2 10.3 1.7 14.9 7.2 73 7 68 165 0.7 0 0.9 0.7 04/04/2007 04:30:00 11.1 1.8 15.3 6.8 11.4 1.8 15.6 7.2 11 1.7 15.6 7.6 73 8 71 165 0.5 0 0.9 0.4 04/04/2007 04:40:00 9.7 1.2 13 6.5 10 1.2 13 7.2 9.6 1.2 13 6.8 72 8 64 165 0.6 0 0.9 0.4 04/04/2007 04:50:00 10 1.9 14.5 5.3 10.3 1.9 14.5 5.7 9.9 1.9 13.7 6.1 70 8 56 165 0.7 0 0.9 0.7 04/04/2007 05:00:00 10 1.4 13.7 6.1 10.4 1.5 13.7 6.5 9.9 1.3 13.3 6.5 68 8 58 165 0.7 0 0.9 0.7 04/04/2007 05:10:00 10.7 1.4 13.7 6.5 11 1.4 13.7 6.5 10.5 1.4 14.1 6.1 67 8 68 165 0.7 0 0.9 0.4 04/04/2007 05:20:00 10.5 1.4 14.1 7.2 10.8 1.5 14.5 7.6 10.4 1.3 14.1 7.2 73 8 66 165 0.5 0 0.9 0.4 04/04/2007 05:30:00 11.6 1.7 16.1 7.6 11.9 1.7 16.4 8 11.3 1.7 15.6 8 77 9 82 165 0.7 0 0.9 0.4 04/04/2007 05:40:00 10.7 1.8 14.9 5.7 11.1 1.8 15.3 6.5 10.5 1.7 14.9 7.2 75 7 81 165 0.8 0 1.1 0.7 04/04/2007 05:50:00 9.7 1.3 13.3 7.2 10.1 1.4 13.7 7.2 9.6 1.3 13 7.2 71 8 62 165 0.8 0 1.1 0.9 04/04/2007 06:00:00 10.9 1.9 15.3 6.1 11.3 1.8 15.6 6.5 10.8 1.9 15.3 5.3 74 8 78 165 0.8 0 1.1 0.7 04/04/2007 06:10:00 10.9 1.5 14.5 6.8 11.2 1.5 14.9 7.6 10.7 1.3 14.5 7.6 73 8 77 165 0.8 0 0.9 0.7 04/04/2007 06:20:00 11.9 1.4 15.3 8 12.2 1.5 15.6 8.8 11.5 1.5 14.9 8 73 8 81 165 0.8 0 1.1 0.9 04/04/2007 06:30:00 11.3 1.5 15.3 7.6 11.6 1.5 15.3 7.6 11.2 1.5 14.9 7.6 70 9 63 165 0.8 0 1.1 0.9 04/04/2007 06:40:00 12.2 1.3 15.6 8 12.5 1.4 16.1 8.4 11.8 1.3 14.9 7.6 70 8 75 165 0.8 0 1.1 0.7 04/04/2007 06:50:00 11.4 1.3 14.9 7.2 11.8 1.3 15.3 8 11.2 1.3 15.3 7.2 72 8 75 165 0.8 0 1.1 0.9 04/04/2007 07:00:00 11.9 1.6 16.1 7.6 12.2 1.6 16.1 8 11.4 1.5 15.6 7.2 74 8 82 165 0.9 0 1.1 0.9 04/04/2007 07:10:00 12.1 1.5 14.9 8.4 12.4 1.6 15.6 8.8 11.8 1.5 15.3 8 74 7 84 165 0.9 0 1.1 0.9 04/04/2007 07:20:00 12.4 1.7 17.9 8.8 12.8 1.7 17.9 8.8 12.1 1.7 16.8 8.4 70 8 58 165 0.9 0 1.1 0.9 04/04/2007 07:30:00 11.6 1.8 16.1 7.6 11.9 1.8 16.8 8.4 11.3 1.7 15.3 7.6 72 8 70 165 0.8 0 1.1 0.7 04/04/2007 07:40:00 11.7 1.5 16.4 8 12 1.5 16.4 8.4 11.4 1.3 15.3 8.4 72 8 74 165 0.8 0 0.9 0.9 04/04/2007 07:50:00 12.2 1.5 16.1 9.5 12.5 1.5 16.4 9.5 11.9 1.4 15.3 8.4 74 8 73 165 0.8 0 1.1 0.7 04/04/2007 08:00:00 11.1 1.5 16.1 7.6 11.4 1.5 16.1 8 10.9 1.4 15.3 8 73 7 74 165 0.8 0 0.9 0.7 04/04/2007 08:10:00 12.4 2.4 17.6 7.2 12.7 2.4 17.9 7.6 12 2.3 17.2 7.6 79 8 87 165 0.8 0 1.1 0.7 04/04/2007 08:20:00 12.6 1.6 17.2 9.1 12.9 1.6 17.6 9.5 12.2 1.6 16.4 8.8 81 8 87 165 0.7 0 0.9 0.7 04/04/2007 08:30:00 11.9 2 16.8 7.6 12.2 2.1 17.6 8 11.4 2 16.8 7.6 77 7 68 165 0.7 0 0.9 0.7 04/04/2007 08:40:00 12.3 1.6 16.4 8 12.6 1.6 16.8 8.4 11.9 1.5 15.3 8.4 76 8 75 165 0.8 0 0.9 0.7 04/04/2007 08:50:00 11.7 1.6 15.6 8.4 12 1.6 16.1 8.4 11.5 1.5 16.1 8.4 80 7 78 165 0.8 0 1.1 0.7 04/04/2007 09:00:00 11 1.7 14.9 6.8 11.3 1.8 15.3 6.8 10.9 1.8 14.9 6.5 75 8 78 165 0.8 0 1.1 0.7 04/04/2007 09:10:00 12.1 1.7 16.1 8 12.4 1.7 16.4 8 11.7 1.8 16.1 7.6 81 9 85 165 0.8 0 0.9 0.7 04/04/2007 09:20:00 12 1.7 16.8 8.4 12.3 1.7 17.2 8.8 11.7 1.6 15.6 7.6 77 8 84 165 0.9 0 1.1 0.9 04/04/2007 09:30:00 12 1.8 16.4 7.6 12.3 1.8 16.4 8 11.8 1.7 16.4 7.6 80 8 85 165 0.9 0 1.4 0.9 04/04/2007 09:40:00 11.9 1.4 16.1 8.8 12.3 1.5 16.1 8.8 11.4 1.5 16.1 8.4 76 7 65 165 0.9 0 1.1 0.9 04/04/2007 09:50:00 11.4 1.5 16.1 8.4 11.7 1.5 16.4 8.4 11.1 1.4 15.6 7.6 72 9 76 165 1.1 0 1.4 0.9 04/04/2007 10:00:00 12.4 1.7 16.8 8.4 12.7 1.7 17.2 9.1 12 1.6 16.1 8 74 8 75 165 1 0.1 1.4 0.9 04/04/2007 10:10:00 11.6 2 17.2 6.8 11.9 2.1 17.6 7.2 11.4 2 16.1 6.5 72 8 68 165 0.7 0 0.9 0.4 04/04/2007 10:20:00 12.7 1.7 16.8 8.4 13 1.6 16.8 8.8 12.2 1.6 16.1 8 78 6 83 165 0.2 0.1 0.7 0.2 04/04/2007 10:30:00 12.3 1.4 15.6 8.4 12.6 1.4 15.6 9.1 11.8 1.3 15.3 8 71 8 62 165 0.2 0 0.7 0.2 04/04/2007 10:40:00 11.9 1.8 16.4 8.4 12.1 1.8 17.2 8.8 11.5 1.8 16.1 7.2 71 8 77 165 0.4 0 0.7 0.2 04/04/2007 10:50:00 11.4 1.7 16.4 8 11.6 1.7 17.2 8.4 11.1 1.5 15.6 7.6 70 8 72 165 0.6 0 0.9 0.4 04/04/2007 11:00:00 12.4 1.5 15.6 8.4 12.6 1.5 16.4 8.4 12 1.5 16.1 8 71 8 66 165 0.8 0 0.9 0.7 04/04/2007 11:10:00 11.8 1.7 16.4 7.6 12.1 1.7 16.8 7.6 11.6 1.7 16.4 7.2 72 8 75 165 0.8 0 1.1 0.7 04/04/2007 11:20:00 11.2 1.9 17.9 6.8 11.5 2 18.3 7.2 10.7 1.9 17.2 6.5 71 9 81 165 0.8 0 0.9 0.7 04/04/2007 11:30:00 12.7 1.9 18.7 8.8 13 2 19.1 8.4 12.4 1.8 18.3 7.2 78 8 70 165 0.6 0 0.9 0.4 04/04/2007 11:40:00 12.2 1.7 17.9 8.8 12.5 1.7 18.3 8.8 12 1.5 16.8 8.8 75 8 78 165 0.4 0 0.7 0.2 04/04/2007 11:50:00 12.2 1.7 17.2 8 12.5 1.7 17.6 8.4 11.9 1.7 17.6 7.6 73 8 72 165 0.2 0 0.7 0.2 04/04/2007 12:00:00 11.4 1.7 16.1 7.2 11.6 1.7 16.4 7.2 11 1.7 15.3 7.2 66 9 77 165 0.2 0 0.4 -0.1 04/04/2007 12:10:00 11.7 1.8 16.4 8 12 1.8 16.8 7.6 11.5 1.6 15.3 7.6 68 8 43 165 0.2 0 0.7 0.2 04/04/2007 12:20:00 11.5 1.7 16.1 8 11.8 1.7 16.8 8 11.3 1.6 16.1 7.6 69 9 74 165 0.4 0 0.7 0.2 04/04/2007 12:30:00 12.1 1.8 16.8 7.6 12.3 1.9 17.6 7.6 11.9 1.7 15.6 8 67 8 68 165 0.4 0 0.7 0.2 04/04/2007 12:40:00 11.8 1.7 16.1 8 12 1.7 16.8 7.6 11.4 1.5 16.1 8 66 9 75 165 0.4 0 0.7 0.2 04/04/2007 12:50:00 12.7 1.7 16.4 8 12.9 1.8 16.8 8 12.2 1.7 16.8 7.6 64 9 71 165 0.5 0 0.7 0.2 04/04/2007 13:00:00 12.7 1.8 18.3 7.2 12.9 1.9 19.1 7.2 12.1 1.6 16.4 7.6 62 9 63 165 0.4 0 0.7 0.2 04/04/2007 13:10:00 12.2 1.7 16.1 8 12.4 1.7 16.4 8 11.7 1.7 15.3 6.1 58 11 50 165 0.5 0 0.7 0.2 04/04/2007 13:20:00 11.8 1.8 16.1 7.6 12 1.9 16.1 7.6 11.3 1.8 15.6 7.2 61 9 65 165 0.5 0 0.7 0.4 04/04/2007 13:30:00 12.6 1.9 17.9 7.6 12.8 2 18.3 8 12.2 1.9 17.9 7.6 62 9 61 165 0.5 0 0.7 0.4 04/04/2007 13:40:00 12.5 1.7 16.1 8.4 12.7 1.8 16.4 8.4 12.2 1.7 16.4 7.6 60 9 73 165 0.5 0 0.7 0.4 04/04/2007 13:50:00 12.4 1.5 17.2 8.4 12.6 1.5 17.2 8.8 12.1 1.3 15.3 8.4 62 9 68 165 0.5 0 0.7 0.2 04/04/2007 14:00:00 12.9 2.1 19.9 8 13 2.2 19.9 8 12.5 2 17.9 7.6 59 9 61 165 0.5 0 0.7 0.2 04/04/2007 14:10:00 12.4 2.2 19.1 7.6 12.5 2.2 19.1 7.6 11.9 2 17.2 8 57 10 59 165 0.5 0 0.7 0.4 04/04/2007 14:20:00 12.2 2.2 19.1 6.8 12.4 2.3 19.5 7.2 11.8 2.1 18.3 7.2 60 9 66 165 0.5 0 0.7 0.4 04/04/2007 14:30:00 12.2 2.4 18.7 6.8 12.4 2.4 19.1 6.8 11.7 2.3 17.9 6.8 58 10 48 165 0.6 0 0.9 0.4 04/04/2007 14:40:00 12.5 2 17.9 8.4 12.6 2.1 18.3 8.4 11.7 1.8 17.6 8 59 10 73 165 0.6 0 0.9 0.4 04/04/2007 14:50:00 12.4 1.7 16.8 8 12.6 1.7 17.2 8 11.9 1.7 16.4 8.4 59 9 68 165 0.6 0 0.9 0.4 04/04/2007 15:00:00 12.2 1.9 16.8 8 12.4 1.9 17.2 7.6 11.8 1.8 17.2 6.8 59 9 61 165 0.6 0 0.9 0.7 04/04/2007 15:10:00 13 1.9 17.6 7.6 13.1 1.9 17.6 8 12.4 1.7 16.4 8 56 8 60 165 0.6 0 0.9 0.4 04/04/2007 15:20:00 11.8 2.8 19.5 5.7 11.9 2.8 19.9 6.1 11.2 2.7 18.7 6.1 57 10 56 165 0.7 0 0.9 0.7 04/04/2007 15:30:00 11.9 2.5 17.9 6.1 12 2.5 17.9 6.5 11.3 2.4 17.6 6.8 54 10 50 165 0.6 0 0.9 0.4 04/04/2007 15:40:00 13.6 2.4 18.7 7.2 13.7 2.5 19.1 7.6 13 2.3 18.3 8 55 10 65 165 0.7 0 0.9 0.4 04/04/2007 15:50:00 12.2 2.1 17.2 7.6 12.3 2.1 17.6 7.6 11.5 1.9 16.8 7.2 52 9 65 165 0.6 0 0.9 0.4 04/04/2007 16:00:00 11.6 2.4 17.6 6.1 11.7 2.4 17.9 6.5 11.2 2.2 16.1 6.5 55 11 58 165 0.7 0 0.9 0.7 04/04/2007 16:10:00 12.2 2.1 17.2 7.6 12.3 2.2 17.6 7.6 11.5 2 16.8 7.6 55 11 74 165 0.7 0 0.9 0.7 04/04/2007 16:20:00 10.9 2.7 16.8 6.1 11 2.7 17.2 6.5 10.4 2.4 16.8 6.1 54 10 78 165 0.7 0 0.9 0.7 04/04/2007 16:30:00 12 2.2 18.3 7.2 12.2 2.2 18.7 7.6 11.5 1.9 16.8 6.8 52 10 74 165 0.7 0 0.9 0.7 04/04/2007 16:40:00 12.4 2.4 19.1 7.2 12.5 2.5 18.7 6.8 11.7 2.2 16.8 6.8 50 10 25 165 0.7 0 0.9 0.7 04/04/2007 16:50:00 11 1.9 15.3 6.5 11.1 1.9 15.3 6.5 10.4 1.7 15.3 6.5 50 9 31 165 0.7 0 0.9 0.7 04/04/2007 17:00:00 12.1 2.2 17.6 5.7 12.2 2.3 18.3 6.5 11.6 2.1 16.8 6.5 47 10 58 165 0.7 0 0.9 0.7 04/04/2007 17:10:00 11.2 1.9 16.4 5.7 11.3 1.9 17.2 6.1 10.7 1.7 14.9 6.5 46 8 56 165 0.7 0 0.9 0.7 04/04/2007 17:20:00 11.1 2 16.1 6.1 11.2 2.1 16.4 6.5 10.7 2 16.1 5.7 48 11 63 165 0.7 0 0.9 0.7 04/04/2007 17:30:00 11.7 2.2 19.1 6.8 11.8 2.2 19.5 6.8 11.3 2 18.3 6.5 47 10 36 165 0.7 0 0.9 0.7 04/04/2007 17:40:00 10.5 2.4 15.6 5.7 10.6 2.4 16.4 5.7 10 2.1 15.3 5.7 44 9 43 165 0.7 0 0.9 0.7 04/04/2007 17:50:00 11.3 2.5 17.2 6.5 11.4 2.5 16.8 6.5 10.7 2.2 16.4 6.1 47 10 57 165 0.7 0 0.9 0.7 04/04/2007 18:00:00 11.8 2.3 19.1 6.8 11.8 2.3 19.1 6.8 11.1 2 17.9 6.8 46 11 59 165 0.8 0 0.9 0.7 04/04/2007 18:10:00 13.3 2.5 19.1 7.2 13.4 2.5 19.5 7.2 12.5 2.2 19.1 8 52 9 74 165 0.8 0 0.9 0.7 04/04/2007 18:20:00 11.7 2.3 17.2 7.2 11.8 2.4 17.6 7.2 11.2 2.2 17.2 6.5 47 11 68 165 0.8 0 0.9 0.7 04/04/2007 18:30:00 13.6 2.3 19.5 7.6 13.7 2.3 19.9 8 12.9 2.5 19.9 8.4 51 10 60 165 0.8 0 0.9 0.7 04/04/2007 18:40:00 13.2 2.5 19.5 6.8 13.3 2.5 19.5 7.2 12.8 2.4 19.5 7.2 53 10 66 165 0.8 0 0.9 0.7 04/04/2007 18:50:00 12.1 2.6 18.7 6.5 12.2 2.6 18.7 6.8 11.5 2.5 17.6 6.5 54 10 58 165 0.8 0 0.9 0.7 04/04/2007 19:00:00 13.7 2.1 19.1 7.6 13.8 2.2 19.5 8 13.1 2.2 18.7 7.2 55 10 63 165 0.8 0 0.9 0.7 04/04/2007 19:10:00 13.5 2.4 20.2 8 13.6 2.4 20.2 8 12.8 2.3 18.7 8.4 56 10 63 165 0.8 0 0.9 0.9 04/04/2007 19:20:00 11.8 2.1 17.9 6.5 11.9 2.1 18.3 6.8 11.4 2 18.3 6.1 49 10 48 165 0.8 0 0.9 0.7 04/04/2007 19:30:00 12.9 2.3 19.5 8 13 2.3 19.5 8 12.4 2.1 18.7 8 57 10 58 165 0.8 0 0.9 0.7 04/04/2007 19:40:00 12.6 2.3 18.7 6.1 12.7 2.4 18.7 6.1 12.2 2.2 17.6 7.2 55 11 63 165 0.8 0 0.9 0.7 04/04/2007 19:50:00 12.9 2.1 17.9 7.2 12.9 2.2 18.3 7.2 12.3 2.1 17.2 6.8 57 11 64 165 0.8 0 1.1 0.9 04/04/2007 20:00:00 12 2.8 19.9 6.8 12.1 2.9 19.9 6.8 11.6 2.9 20.6 6.5 56 11 54 165 0.8 0 1.1 0.9 04/04/2007 20:10:00 13.1 2.4 19.1 6.5 13.2 2.4 19.1 6.8 12.7 2.2 18.3 7.2 57 9 70 165 0.9 0 1.1 0.9 04/04/2007 20:20:00 12.1 1.9 16.4 6.8 12.3 1.9 16.4 7.6 11.9 1.8 16.1 8 56 10 40 165 0.9 0 1.1 0.9 04/04/2007 20:30:00 13 2.2 18.7 7.6 13.1 2.3 19.1 8.4 12.4 2.4 18.7 7.2 57 10 66 165 0.8 0 1.1 0.9 04/04/2007 20:40:00 12.1 2 16.4 6.8 12.2 2.1 16.8 6.5 11.7 2 16.8 6.5 55 11 50 165 0.8 0 0.9 0.9 04/04/2007 20:50:00 13.7 2.6 22.6 7.6 13.9 2.6 22.9 7.6 13.6 2.6 22.6 8 56 9 60 165 0.8 0 1.1 0.9 04/04/2007 21:00:00 13.7 2.3 19.5 8.4 13.7 2.3 19.5 8 13.3 2.2 18.7 8 56 9 54 165 0.8 0 1.1 0.9 04/04/2007 21:10:00 13.6 2.1 19.5 9.1 13.7 2.1 19.9 8.8 13.2 2 19.1 8.4 59 9 58 165 0.9 0 1.1 0.9 04/04/2007 21:20:00 13.5 2.3 19.1 7.6 13.6 2.3 19.1 8 13.2 2.2 18.7 8 60 9 68 165 0.9 0 1.1 0.9 04/04/2007 21:30:00 12.9 2.1 19.9 8 13 2.2 19.9 8.4 12.8 2.2 19.5 8.8 58 11 64 165 0.9 0 1.1 0.9 04/04/2007 21:40:00 13.5 2.4 19.9 7.2 13.6 2.4 20.2 7.2 13.4 2.2 19.9 7.2 57 10 64 165 0.9 0 1.1 0.9 04/04/2007 21:50:00 13.6 2.1 19.9 8.4 13.6 2.1 19.9 8.8 13.4 2.1 20.6 8 58 9 72 165 0.9 0 1.1 0.9 04/04/2007 22:00:00 13.1 1.8 18.3 8 13.2 1.9 18.7 8 13 1.8 17.9 8.8 57 8 52 165 0.9 0 1.1 0.9 04/04/2007 22:10:00 13.1 2.4 19.1 8 13.1 2.4 19.1 8 13 2.3 19.1 7.2 59 10 58 165 0.9 0 1.1 0.9 04/04/2007 22:20:00 12.8 1.9 17.6 8.8 12.9 2.1 17.9 8.4 12.7 2 18.3 8.4 58 8 73 165 0.9 0 1.1 0.9 04/04/2007 22:30:00 12.6 2.4 19.9 6.8 12.7 2.5 19.9 7.2 12.5 2.4 18.7 8 65 10 73 165 0.9 0 1.1 0.9 04/04/2007 22:40:00 12.8 1.9 18.3 8 12.8 2 18.3 8 12.6 2 17.9 7.2 66 6 61 165 0.9 0 1.1 0.9 04/04/2007 22:50:00 14 2.3 20.2 9.1 14.1 2.4 20.6 9.1 13.9 2.4 20.6 9.5 61 0 61 165 1 0 1.1 0.9 04/04/2007 23:00:00 12.8 1.8 18.7 8.8 12.8 1.9 18.7 8.4 12.8 1.9 18.3 8 61 0 61 165 1 0 1.1 0.9 04/04/2007 23:10:00 14 2.5 20.2 7.6 14 2.5 20.6 7.2 13.7 2.5 21.4 6.8 61 0 61 165 1 0 1.4 0.9 04/04/2007 23:20:00 12.8 2.3 19.1 7.6 12.8 2.4 19.1 7.6 12.6 2.2 17.6 8.4 61 0 61 165 1 0 1.4 0.9 04/04/2007 23:30:00 13.5 2 18.3 7.6 13.5 2.1 18.3 7.2 13.3 2.2 18.7 7.6 61 0 61 165 1.1 0 1.4 0.9 04/04/2007 23:40:00 13.7 2.5 21 8 13.7 2.5 21.4 8.8 13.3 2.3 20.2 8 61 0 61 165 1.1 0 1.4 0.9 04/04/2007 23:50:00 12.8 1.9 17.9 8.4 12.8 2 17.9 8.8 12.7 2 17.6 8.4 61 0 61 165 1 0 1.1 0.9 04/05/2007 00:00:00 12.7 1.7 18.3 9.5 12.7 1.7 18.3 9.1 12.6 1.7 17.9 9.1 61 0 61 165 0.9 0 1.1 0.9 04/05/2007 00:10:00 11.9 1.7 17.2 7.6 11.9 1.8 16.8 8 11.8 1.9 17.9 8 61 0 61 165 0.9 0 1.1 0.9 04/05/2007 00:20:00 12.2 2.1 18.3 7.6 12.1 2.2 18.3 7.6 12.3 2.1 17.9 7.6 61 0 61 165 1 0 1.4 0.9 04/05/2007 00:30:00 13.1 2 17.6 8.8 13.1 2.1 17.6 8.4 13 2.1 17.9 8 61 0 61 165 1.1 0 1.4 0.9 04/05/2007 00:40:00 13.1 2.2 19.1 8.4 13.1 2.3 19.5 8.4 13.2 2.2 19.9 7.6 61 0 61 165 1.1 0 1.4 0.9 04/05/2007 00:50:00 13.1 2.6 18.7 6.5 13 2.6 18.7 6.5 13.1 2.5 19.1 7.2 61 0 61 165 1.1 0 1.4 0.9 04/05/2007 01:00:00 12.3 2.1 17.9 8 12.3 2.1 17.9 8 12.4 2.1 17.6 7.2 61 0 61 165 1.1 0 1.4 0.9 04/05/2007 01:10:00 12.3 2 17.2 8.4 12.2 2 16.8 8.4 12.4 1.9 17.6 8 61 0 61 165 1.1 0 1.4 0.9 04/05/2007 01:20:00 12.3 2.1 17.6 6.5 12.3 2.2 17.6 6.1 12.6 2.1 17.2 6.8 61 0 61 165 1.1 0 1.4 0.9 04/05/2007 01:30:00 12.8 1.7 16.8 7.6 12.7 1.8 16.4 7.6 12.7 1.9 17.2 8.4 61 0 61 165 1.2 0 1.4 0.9 04/05/2007 01:40:00 13 1.8 17.6 9.1 12.8 1.8 17.6 9.1 13 1.9 17.9 8.4 61 0 61 165 1.2 0 1.4 1.1 04/05/2007 01:50:00 12.4 2.1 18.3 8 12.3 2.1 17.9 7.2 12.5 2.1 17.2 7.6 60 0 61 165 1.3 0 1.4 1.1 04/05/2007 02:00:00 12.2 2.4 17.6 6.5 12.1 2.4 17.2 6.5 12.2 2.4 18.3 6.5 60 0 61 165 1.3 0 1.4 1.1 04/05/2007 02:10:00 12 2 16.8 7.6 11.9 2 16.8 7.6 12.1 2 17.2 8 60 0 61 165 1.2 0 1.4 1.1 04/05/2007 02:20:00 12.3 1.8 16.1 7.6 12.2 1.8 16.4 7.6 12.4 2 17.2 8 60 0 60 165 1.3 0 1.4 1.1 04/05/2007 02:30:00 12.2 1.9 16.8 7.6 12 1.9 16.4 8 12.4 2 16.8 7.6 60 0 61 165 1.3 0 1.4 1.4 04/05/2007 02:40:00 13 2.4 19.9 8 12.9 2.4 19.5 7.6 13.2 2.5 19.9 8 60 0 61 165 1.4 0 1.6 1.4 04/05/2007 02:50:00 11.8 2.4 18.3 6.1 11.8 2.4 18.3 6.1 11.8 2.5 19.5 6.1 60 0 60 165 1.4 0 1.6 1.1 04/05/2007 03:00:00 12.8 2.4 18.7 7.6 12.7 2.4 18.7 7.6 13 2.4 18.7 8 60 0 60 165 1.4 0 1.6 1.4 04/05/2007 03:10:00 12.4 2 17.6 8 12.3 1.9 17.2 8 12.5 2 17.9 7.6 60 0 61 165 1.4 0 1.6 1.4 04/05/2007 03:20:00 12 2.4 17.9 6.8 11.9 2.3 17.9 6.8 12.2 2.5 18.7 6.1 60 0 60 165 1.4 0 1.6 1.4 04/05/2007 03:30:00 11.6 1.9 16.1 6.8 11.4 1.9 15.6 6.5 11.7 2 16.8 6.5 60 0 60 165 1.4 0 1.6 1.4 04/05/2007 03:40:00 11.8 2.1 16.8 7.6 11.6 2 17.2 7.2 12.1 2.2 17.6 7.6 60 0 60 165 1.4 0 1.6 1.4 04/05/2007 03:50:00 12.1 1.8 17.2 7.6 11.9 1.8 16.8 7.2 12.2 2 17.2 7.2 60 0 59 165 1.4 0 1.6 1.4 04/05/2007 04:00:00 12.5 2 16.8 7.6 12.1 2 16.4 7.6 12.5 2.3 17.2 6.8 59 0 58 165 1.4 0 1.6 1.4 04/05/2007 04:10:00 12.1 1.9 16.8 8.4 11.4 1.9 16.1 7.6 12 2.1 17.2 7.2 59 0 59 165 1.4 0 1.6 1.4 04/05/2007 04:20:00 11.5 2 16.4 7.2 11 2 15.6 6.8 11.4 2.1 16.8 6.8 60 0 60 165 1.4 0 1.6 1.4 04/05/2007 04:30:00 12.9 1.9 17.9 8.4 12.4 1.8 17.2 8 13 2 18.3 8.4 60 0 61 165 1.4 0 1.6 1.4 04/05/2007 04:40:00 10.4 1.7 15.6 6.5 9.8 1.7 15.3 5.7 10.2 1.7 16.1 6.8 60 0 60 165 1.4 0 1.6 1.4 04/05/2007 04:50:00 11 1.8 16.1 7.6 10.4 1.8 16.1 6.8 11 2 16.8 7.2 60 0 60 165 1.4 0 1.6 1.4 04/05/2007 05:00:00 11.5 1.9 17.2 6.8 11 1.9 16.8 6.8 11.4 2.1 18.3 6.5 60 0 60 165 1.4 0 1.8 1.4 04/05/2007 05:10:00 11.1 2 16.1 6.8 10.6 2.1 15.6 6.1 11.1 2.2 16.1 6.5 60 0 60 165 1.4 0 1.6 1.4 04/05/2007 05:20:00 10.2 1.8 15.3 6.8 9.6 1.9 14.9 6.1 10 1.8 14.9 6.5 60 0 60 165 1.4 0 1.6 1.4 04/05/2007 05:30:00 11.9 1.7 15.6 7.6 10.9 1.7 15.3 7.2 11.6 1.9 16.8 7.6 60 0 61 165 1.4 0 1.6 1.4 04/05/2007 05:40:00 12 1.7 16.4 8 10.9 1.7 15.3 6.8 11.8 1.7 16.4 6.8 60 0 60 165 1.4 0 1.6 1.4 04/05/2007 05:50:00 9.9 2.1 14.5 5.7 8.8 2 13.7 5.3 9.8 2.2 16.4 5.3 60 0 61 165 1.3 0 1.6 1.1 04/05/2007 06:00:00 10.9 1.6 16.1 6.8 10.1 1.7 16.1 5.7 10.9 1.7 15.3 6.1 60 0 60 165 1.2 0 1.4 1.1 04/05/2007 06:10:00 11.2 1.3 16.4 8.4 10.8 1.5 15.3 7.6 11.1 1.6 16.4 6.8 60 0 60 165 1.2 0 1.4 1.1 04/05/2007 06:20:00 11.7 1.5 17.6 8.4 11.5 1.6 16.4 7.6 11.8 1.7 17.2 7.2 60 0 60 165 1.2 0 1.4 0.9 04/05/2007 06:30:00 10.9 1.3 14.1 8 10.4 1.4 14.1 7.6 10.6 1.4 14.1 7.6 60 0 60 165 1.2 0 1.4 0.9 04/05/2007 06:40:00 11 1.5 15.3 7.2 10.4 1.7 14.9 6.5 10.9 1.9 14.9 6.8 60 0 61 165 1.1 0 1.4 0.9 04/05/2007 06:50:00 10.8 1.3 14.1 6.8 10.3 1.3 14.1 6.8 10.6 1.6 14.5 6.8 60 0 60 165 1.1 0 1.4 0.9 04/05/2007 07:00:00 9.4 1.2 13 6.1 9.3 1.4 14.1 5.7 8.8 1.7 12.6 4.6 60 0 60 165 1.1 0 1.4 0.9 04/05/2007 07:10:00 11 1.6 15.3 7.2 11.1 1.9 16.1 6.5 10.5 2 14.9 6.1 60 0 60 165 1.1 0 1.4 0.9 04/05/2007 07:20:00 10.4 1.4 13.7 6.5 10.3 1.6 14.5 5.3 9.8 1.8 14.5 4.9 60 0 60 165 1.1 0 1.4 0.9 04/05/2007 07:30:00 11 1.5 13.7 6.8 10.9 1.6 14.1 6.1 11.2 1.5 14.5 6.5 60 0 60 165 1.1 0 1.4 0.9 04/05/2007 07:40:00 10.6 1.3 13.7 7.6 10.6 1.5 14.1 6.8 10.5 1.4 14.5 7.6 60 0 60 165 1 0 1.1 0.9 04/05/2007 07:50:00 10 1.2 13 7.2 9.8 1.4 13.3 6.5 9.8 1.3 13.3 6.5 60 0 60 165 1 0 1.1 0.9 04/05/2007 08:00:00 9.8 1.5 13.7 6.5 9.5 1.7 13.7 5.7 9.8 1.8 14.5 5.3 60 0 60 165 1 0 1.4 0.9 04/05/2007 08:10:00 10 1.2 13.7 7.6 9.5 1.4 13.7 6.5 10.2 1.5 14.9 6.1 60 0 60 165 1 0 1.4 0.9 04/05/2007 08:20:00 9.7 1.1 12.6 7.2 9.2 1.3 13 6.1 9.8 1.3 13 6.1 60 0 60 165 0.9 0 1.1 0.9 04/05/2007 08:30:00 9.3 1.1 12.2 6.1 8.7 1.3 12.2 5.7 9.2 1.3 12.6 6.1 60 0 60 165 0.9 0 1.1 0.9 04/05/2007 08:40:00 10.4 1.2 13.3 7.2 10.1 1.5 13.7 6.1 11.6 1.7 16.1 6.8 60 0 60 165 0.9 0 1.1 0.9 04/05/2007 08:50:00 9.7 1.2 12.6 6.5 9.1 1.5 13 5.7 11.2 1.7 15.3 8 60 0 60 165 1 0 1.1 0.9 04/05/2007 09:00:00 9.3 1.1 12.6 6.5 8.5 1.3 12.2 5.3 10.9 1.7 15.6 7.2 60 0 60 165 1 0 1.4 0.9 04/05/2007 09:10:00 9.8 1.1 12.6 6.8 9 1.4 13 5.7 11.8 1.7 16.1 7.2 60 0 60 165 1.1 0 1.4 0.9 04/05/2007 09:20:00 9.5 1.2 12.6 6.5 8.5 1.5 12.2 4.9 11.4 1.9 15.6 6.8 60 0 60 165 1.1 0 1.4 0.9 04/05/2007 09:30:00 9 1.1 11.8 5.7 7.5 1.3 11.1 4.2 10.4 1.5 14.9 6.8 60 0 60 165 1.1 0 1.4 0.9 04/05/2007 09:40:00 9 1 11.5 6.8 7.5 1 11.5 5.7 10.7 1.7 15.3 6.8 60 0 60 165 0.9 0 1.1 0.9 04/05/2007 09:50:00 9.2 1 11.8 6.5 8.4 1.3 11.8 5.3 11 1.4 14.9 7.6 60 0 60 165 0.9 0 1.1 0.9 04/05/2007 10:00:00 9.2 0.9 11.1 6.8 8.6 1.3 11.5 5.3 11.1 1.3 14.9 8 60 0 60 165 1 0 1.1 0.9 04/05/2007 10:10:00 8.3 1.4 11.5 5.7 6.7 1.3 11.5 3.8 10.2 1.9 15.3 6.8 60 0 60 165 1.1 0 1.4 0.9 04/05/2007 10:20:00 7.8 1.1 9.9 5.3 6.2 0.8 7.6 3.8 9.6 1.5 13 6.1 60 0 60 165 1.1 0 1.4 0.9 04/05/2007 10:30:00 8.1 1.1 10.7 4.9 6.3 0.7 7.2 3 10.2 1.5 14.1 6.1 60 0 60 165 1.1 0 1.4 0.9 04/05/2007 10:40:00 8 0.7 10.3 5.3 6.4 0.5 7.2 4.2 10 1.1 12.6 6.5 60 0 61 165 1.1 0 1.4 0.9 04/05/2007 10:50:00 7.1 1.2 9.9 4.9 5.8 0.8 7.2 3 8.5 1.6 12.6 5.7 60 0 61 165 1.2 0 1.4 0.9 04/05/2007 11:00:00 7.6 1 11.1 4.9 6.2 0.6 7.2 4.6 9.5 1.3 13.3 5.7 60 0 60 165 1.2 0 1.4 1.1 04/05/2007 11:10:00 7.1 1.2 9.5 4.6 5.7 0.9 6.8 3 8.8 1.6 13 5.3 60 0 60 165 1.2 0 1.4 1.1 04/05/2007 11:20:00 7.3 1.1 10.3 4.9 5.3 0.9 6.8 1.9 8.4 1.5 12.2 4.6 60 0 60 165 1.2 0 1.4 1.1 04/05/2007 11:30:00 9 1.3 12.6 5.7 5.3 1 6.8 2.3 8.8 1.6 12.2 5.3 60 0 60 165 1.2 0 1.4 1.1 04/05/2007 11:40:00 7.8 1.1 10.7 4.9 1.3 1.8 6.1 0.4 7 1.3 10.3 4.2 60 0 60 165 1.3 0 1.4 1.1 04/05/2007 11:50:00 8.3 1.5 11.8 4.9 0.5 0.9 6.8 0.4 8.2 1.9 12.2 4.2 60 0 61 165 1.3 0 1.4 1.1 04/05/2007 12:00:00 7.6 1 10.3 5.3 4.4 1 6.1 1.9 7.4 0.6 8.8 5.7 60 0 61 165 1.3 0 1.6 1.4 04/05/2007 12:10:00 8 1.1 11.1 6.1 4.8 0.8 6.5 2.6 7.6 0.6 9.1 5.7 60 0 60 165 1.4 0 1.4 1.4 04/05/2007 12:20:00 7.4 1.3 10.3 4.6 1.9 2 5.7 0.4 7.1 0.8 8.8 4.2 60 0 60 165 1.4 0 1.6 1.4 04/05/2007 12:30:00 7.8 1.2 10.7 4.9 0.4 0 0.4 0.4 7.2 0.6 8.8 5.3 60 0 60 165 1.4 0 1.6 1.4 04/05/2007 12:40:00 7.4 1.5 11.8 4.9 0.4 0 0.4 0.4 6.8 0.9 8.8 4.6 60 0 60 165 1.4 0 1.6 1.4 04/05/2007 12:50:00 6.9 1.3 11.8 4.2 0.4 0 0.4 0.4 6.9 1 8.8 3.4 60 0 60 165 1.4 0 1.6 1.4 04/05/2007 13:00:00 5.4 0.7 6.8 3.4 0.4 0 0.4 0.4 6.6 0.9 8.4 4.2 60 0 61 165 1.4 0 1.6 1.4 04/05/2007 13:10:00 4.8 0.7 6.5 2.6 0.4 0 0.4 0.4 5.8 0.9 7.6 3.8 60 0 61 165 1.4 0 1.6 1.4 04/05/2007 13:20:00 5.6 0.5 6.8 4.2 0.4 0 0.4 0.4 6.8 0.9 8.4 4.2 60 0 61 165 1.4 0 1.6 1.4 04/05/2007 13:30:00 5.2 0.5 6.1 3.4 0.4 0 0.4 0.4 6.1 0.7 7.6 4.2 60 0 61 165 1.4 0 1.6 1.4 04/05/2007 13:40:00 4.8 0.8 6.1 2.3 0.4 0 0.4 0.4 5.8 1.1 8 3 60 0 61 165 1.4 0 1.6 1.4 04/05/2007 13:50:00 4.8 0.8 6.5 2.6 0.4 0 0.4 0.4 5.8 1.1 8 3.4 60 0 60 165 1.4 0 1.6 1.4 04/05/2007 14:00:00 4.5 0.8 6.1 1.9 0.4 0 0.4 0.4 5.6 1 7.6 3 60 0 60 165 1.5 0 1.6 1.4 04/05/2007 14:10:00 5.2 0.6 6.8 3.8 0.4 0 0.4 0.4 6.3 0.7 7.6 4.6 61 0 62 165 1.5 0 1.6 1.4 04/05/2007 14:20:00 5.7 0.5 6.8 3.8 0.4 0 0.4 0.4 7 0.4 7.6 5.7 81 8 89 165 1.5 0 1.6 1.4 04/05/2007 14:30:00 6 0.6 7.2 4.6 0.4 0 0.4 0.4 6.7 0.5 7.6 4.6 109 13 114 165 1.5 0 1.8 1.4 04/05/2007 14:40:00 6.6 0.5 7.6 5.3 0.4 0 0.4 0.4 6.8 0.4 7.6 5.7 130 6 138 165 1.5 0 1.6 1.4 04/05/2007 14:50:00 7.1 0.4 8 6.1 0.4 0 0.4 0.4 7.3 0.4 8.4 6.1 139 8 139 165 1.5 0 1.6 1.4 04/05/2007 15:00:00 7.2 0.3 7.6 6.5 0.4 0 0.4 0.4 7.5 0.3 8 6.8 146 5 148 165 1.5 0 1.6 1.4 04/05/2007 15:10:00 7 0.2 7.6 6.5 0.4 0 0.4 0.4 7.3 0.2 7.6 6.5 148 6 135 165 1.5 0 1.6 1.4 04/05/2007 15:20:00 6.8 0.2 7.2 6.5 0.4 0 0.4 0.4 7.1 0.2 7.6 6.5 151 7 136 165 1.5 0 1.8 1.4 04/05/2007 15:30:00 6.6 0.2 6.8 6.1 0.5 0.7 5.7 0.4 6.8 0.2 7.2 6.1 151 3 156 165 1.5 0 1.8 1.4 04/05/2007 15:40:00 7.6 2.3 19.5 6.5 6.3 0.8 7.6 4.9 11.3 4 18.7 6.5 144 5 142 165 1.5 0 1.6 1.4 04/05/2007 15:50:00 17.5 1 19.5 14.9 7.7 0.6 8.8 6.5 17.1 1 19.1 14.5 144 5 145 165 1.5 0 1.6 1.4 04/05/2007 16:00:00 17 1.2 20.6 14.1 10.9 3.6 19.9 8.4 16.8 1.3 20.2 12.6 142 6 151 165 1.6 0 1.8 1.4 04/05/2007 16:10:00 18.7 1.4 21.8 14.1 18.7 1.4 21.8 14.1 18.5 1.6 21.8 13 139 8 133 165 1.7 0 2.1 1.4 04/05/2007 16:20:00 18.8 1.3 22.6 14.9 18.7 1.3 22.1 14.5 18.5 1.4 22.1 13.3 139 6 141 165 1.9 0.2 2.6 1.6 04/05/2007 16:30:00 18.8 1.3 22.6 14.9 18.7 1.3 22.6 14.9 18.1 1.5 22.1 14.5 135 7 119 165 1.8 0.1 2.3 1.6 04/05/2007 16:40:00 19.2 1.5 23.3 14.9 19.1 1.5 22.9 14.5 18.8 1.7 22.9 13.3 137 7 141 165 2.9 0 3 2.6 04/05/2007 16:50:00 18.2 1.5 21.8 13 18.1 1.5 21.4 13.3 17.8 1.7 22.1 11.5 137 6 139 165 2.9 0 3 2.8 04/05/2007 17:00:00 18 1.3 22.1 14.1 17.9 1.3 21.8 13.7 17.7 1.3 21 14.1 138 6 125 165 2.9 0 3 2.8 04/05/2007 17:10:00 16.7 1.1 19.5 14.1 16.7 1.1 19.5 13.7 16.1 1.2 19.1 11.5 136 8 140 165 2.9 0 3 2.8 04/05/2007 17:20:00 17.6 1.3 21 13.3 17.5 1.3 21.4 13.7 17.1 1.5 20.6 12.6 135 8 139 165 2.9 0 3 2.8 04/05/2007 17:30:00 17.8 1.6 21.4 13.7 17.8 1.6 21.4 12.6 17.3 1.7 21.4 12.6 136 8 131 165 2.9 0 3 2.8 04/05/2007 17:40:00 18.7 1.5 22.9 14.5 18.7 1.5 22.6 14.1 18.2 1.7 22.1 13 134 7 132 165 2.9 0 3 2.8 04/05/2007 17:50:00 18.1 1.5 22.1 14.5 18.1 1.5 22.1 14.5 17.6 1.6 21.8 13 135 7 136 165 2.9 0 3 2.8 04/05/2007 18:00:00 18.2 1.3 21.4 14.1 18.3 1.4 21.8 13 17.7 1.7 21 13 132 6 128 165 2.9 0 3.3 2.8 04/05/2007 18:10:00 17.8 1.7 22.6 12.2 17.8 1.7 22.1 12.2 17.3 1.9 21.4 12.6 131 7 124 165 2.9 0 3 2.8 04/05/2007 18:20:00 18.3 1.2 22.1 15.3 18.2 1.2 22.1 14.5 17.6 1.6 22.1 13 133 6 130 165 2.9 0 3 2.8 04/05/2007 18:30:00 18.7 1.5 23.3 14.9 18.8 1.5 23.3 14.5 18.5 1.6 23.3 14.5 132 6 116 165 2.9 0 3 2.8 04/05/2007 18:40:00 17.7 1.5 21.8 13 17.6 1.5 21.4 13.3 16.9 1.7 21 12.2 131 7 136 165 2.9 0 3 2.8 04/05/2007 18:50:00 18.6 1.6 23.3 14.5 18.6 1.6 23.3 14.5 18.2 1.6 22.9 13.3 130 7 128 165 2.9 0 3 2.8 04/05/2007 19:00:00 17.9 1.7 22.1 12.6 17.9 1.7 22.6 12.2 17.3 2.1 22.1 11.8 130 7 133 165 2.9 0 3 2.6 04/05/2007 19:10:00 19.1 1.7 24 15.6 19.1 1.7 24 15.3 18.7 1.7 23.3 13 130 6 128 165 2.9 0 3 2.8 04/05/2007 19:20:00 20.1 1.9 25.2 15.6 20.1 1.9 25.6 14.9 19.6 2 24 14.5 131 6 128 165 2.9 0 3 2.8 04/05/2007 19:30:00 19.2 1.5 22.9 15.3 19.1 1.5 22.9 15.3 18.6 1.7 22.9 14.1 134 7 129 165 2.8 0 3 2.6 04/05/2007 19:40:00 19.5 1.5 23.7 14.1 19.4 1.5 23.3 14.5 18.8 1.7 22.1 13 134 6 141 165 2.8 0 2.8 2.6 04/05/2007 19:50:00 20 1.5 24 15.3 20 1.5 23.7 15.6 19.5 1.7 24.4 15.3 135 6 128 165 2.8 0 3 2.6 04/05/2007 20:00:00 19.6 1.3 22.6 16.1 19.5 1.3 22.6 15.3 19 1.5 22.6 14.5 136 6 136 165 2.8 0 2.8 2.6 04/05/2007 20:10:00 19.8 1.5 23.3 16.1 19.7 1.4 23.3 16.1 19.4 1.4 22.9 14.9 137 6 137 165 2.8 0 3 2.6 04/05/2007 20:20:00 19.3 1.6 23.7 15.3 19.3 1.7 23.3 14.5 18.8 1.8 22.9 12.6 134 7 126 165 2.8 0 3 2.6 04/05/2007 20:30:00 17.8 1.3 21.4 14.1 17.7 1.3 21.4 14.1 17 1.6 21.8 12.2 136 7 141 165 2.7 0 2.8 2.6 04/05/2007 20:40:00 17.9 1.5 22.1 13.3 17.8 1.5 22.1 13.7 17.4 1.7 22.1 13 136 7 124 165 2.7 0 2.8 2.6 04/05/2007 20:50:00 17.9 1.4 21.8 13.7 17.9 1.4 22.1 13.7 17.6 1.6 21.8 13 136 6 131 165 2.7 0 2.8 2.6 04/05/2007 21:00:00 17.4 1.5 21 13 17.4 1.5 21 13.3 16.8 1.7 21 11.8 136 5 139 165 2.7 0 2.8 2.6 04/05/2007 21:10:00 17.3 1.5 21.4 11.1 17.3 1.5 21 11.8 16.7 1.7 21 13 134 7 141 165 2.6 0 2.8 2.6 04/05/2007 21:20:00 17.4 1.8 21.4 13.7 17.4 1.8 21.4 13.7 16.8 1.8 20.6 12.6 134 6 140 165 2.5 0 2.8 2.3 04/05/2007 21:30:00 16.7 1.7 21 12.6 16.7 1.8 21 12.6 16.4 1.9 21 11.8 133 6 128 165 2.6 0 2.8 2.3 04/05/2007 21:40:00 17.7 1.8 22.6 12.2 17.6 1.8 22.6 12.2 17.4 1.8 23.3 13.3 135 7 135 165 2.5 0 2.8 2.6 04/05/2007 21:50:00 17.1 1.3 20.2 13.7 17.1 1.3 20.2 13.7 16.4 1.6 19.9 11.1 134 7 139 165 2.5 0 2.8 2.3 04/05/2007 22:00:00 17.4 1.3 20.6 13.3 17.4 1.3 21 13.7 17.2 1.3 20.6 12.6 138 6 131 165 2.5 0 3 2.3 04/05/2007 22:10:00 17.6 1.5 21.8 13 17.6 1.5 21.8 13.7 17.3 1.6 21.8 12.6 134 6 132 165 2.6 0 2.8 2.3 04/05/2007 22:20:00 17.1 1.5 21.8 12.6 17.1 1.5 21.8 13 16.5 1.7 20.6 11.8 132 7 131 165 2.7 0 2.8 2.6 04/05/2007 22:30:00 17.4 1.4 22.1 13.7 17.4 1.5 22.1 13.3 16.9 1.6 21.8 11.8 130 7 122 165 2.7 0 2.8 2.6 04/05/2007 22:40:00 17.8 1.3 22.1 13.7 17.8 1.3 22.6 13.7 17.5 1.5 21.4 13.7 131 7 129 165 2.7 0 2.8 2.6 04/05/2007 22:50:00 17.9 1.5 21 13 18 1.5 21.4 13.3 17.3 1.7 21 12.6 129 6 138 165 2.7 0 3 2.6 04/05/2007 23:00:00 17.6 1.9 23.7 12.6 17.7 1.9 24 13 17.2 2 22.9 12.6 128 8 127 165 2.7 0 2.8 2.6 04/05/2007 23:10:00 16.8 1.5 20.6 13.7 16.9 1.5 20.6 13.3 16.5 1.6 21 12.6 132 6 129 165 2.7 0 3 2.6 04/05/2007 23:20:00 16.6 1.6 20.6 12.6 16.7 1.6 20.6 13 16.2 1.7 20.6 12.2 128 6 126 165 2.7 0 2.8 2.6 04/05/2007 23:30:00 16.9 1.3 19.9 13 17.1 1.3 20.6 13 16.5 1.5 19.5 12.6 128 7 116 165 2.7 0 2.8 2.6 04/05/2007 23:40:00 17.3 1.6 21.8 13.3 17.3 1.5 21.8 13.3 17 1.7 22.1 13 129 6 126 165 2.8 0 3 2.6 04/05/2007 23:50:00 16.9 1.3 20.2 12.6 17 1.2 19.9 12.6 16.6 1.3 19.9 11.1 127 7 125 165 2.8 0 3 2.6 04/06/2007 00:00:00 17.1 1.5 22.6 11.8 17.1 1.6 22.9 12.2 16.6 1.7 22.6 12.2 129 6 119 165 2.8 0 3 2.3 04/06/2007 00:10:00 16.8 1.5 21 13 16.8 1.5 21.4 13.3 16.3 1.7 20.6 12.2 131 7 127 165 2.8 0 3 2.6 04/06/2007 00:20:00 16.7 1.8 20.6 11.8 16.8 1.8 20.6 11.8 16.2 2 21 11.5 127 7 122 165 2.8 0 3 2.6 04/06/2007 00:30:00 17.5 1.3 21.4 14.1 17.6 1.3 21 13.7 17.2 1.4 20.6 13.7 128 6 124 165 2.8 0 3 2.6 04/06/2007 00:40:00 16.8 1.5 21.8 13.3 16.8 1.5 22.1 13.7 16 1.7 20.2 11.8 126 7 124 165 2.8 0 2.8 2.6 04/06/2007 00:50:00 17 1.3 20.2 12.6 17.1 1.3 20.6 12.2 16.4 1.2 19.5 13.3 124 7 119 165 2.8 0 2.8 2.6 04/06/2007 01:00:00 16.2 1.2 20.2 13.3 16.4 1.2 20.2 13.3 16 1.3 20.6 12.6 125 5 128 165 2.7 0 2.8 2.6 04/06/2007 01:10:00 16.4 1.5 21 12.6 16.6 1.5 21.4 12.2 16.1 1.7 20.6 9.5 123 7 113 165 2.7 0 2.8 2.6 04/06/2007 01:20:00 16.3 1.5 20.6 12.2 16.5 1.5 21 11.8 15.9 1.5 19.5 11.8 123 5 120 165 2.7 0 2.8 2.6 04/06/2007 01:30:00 16.3 1.4 19.5 12.6 16.4 1.4 19.5 12.6 15.7 1.5 20.6 12.2 124 6 129 165 2.7 0 2.8 2.6 04/06/2007 01:40:00 15.9 1.3 19.5 12.6 15.9 1.3 19.9 12.6 15.3 1.5 19.5 10.7 129 6 129 165 2.7 0 2.8 2.6 04/06/2007 01:50:00 16 1.3 20.2 12.2 16.1 1.3 20.6 11.8 15.6 1.3 19.9 12.6 128 5 126 165 2.8 0 2.8 2.6 04/06/2007 02:00:00 15.7 1.4 19.9 11.8 15.9 1.5 20.6 10.7 15.3 1.5 20.2 9.9 128 6 117 165 2.7 0 3 2.6 04/06/2007 02:10:00 15.7 1.3 19.1 11.8 15.8 1.3 19.5 11.8 15.4 1.4 19.5 11.5 127 7 121 165 2.7 0 2.8 2.6 04/06/2007 02:20:00 14.6 1.3 18.3 10.7 14.7 1.3 18.7 10.7 14.3 1.3 17.6 10.7 126 5 124 165 2.6 0 2.8 2.6 04/06/2007 02:30:00 14.3 1.3 17.2 10.7 14.4 1.3 17.6 10.7 13.9 1.3 16.8 9.9 123 6 112 165 2.6 0 2.8 2.6 04/06/2007 02:40:00 14 1.7 17.9 9.5 14.1 1.7 18.3 9.9 13.7 1.7 17.9 9.5 128 7 116 165 2.5 0 2.8 2.3 04/06/2007 02:50:00 14.4 1.5 18.3 11.1 14.5 1.5 18.7 11.5 14 1.5 17.9 9.9 128 6 121 165 2.5 0 2.8 2.3 04/06/2007 03:00:00 14.2 1.6 18.3 10.7 14.3 1.6 18.3 11.1 13.8 1.7 18.7 8.8 126 7 128 165 2.4 0 2.6 2.3 04/06/2007 03:10:00 13.8 1.5 17.2 10.7 13.9 1.5 17.6 10.3 13.3 1.5 16.4 9.5 122 5 106 165 2.3 0 2.6 2.1 04/06/2007 03:20:00 12.3 1.1 15.3 8.8 12.5 1.1 15.3 9.1 11.7 1.3 14.1 8 114 8 112 165 2.2 0 2.3 2.1 04/06/2007 03:30:00 12.5 1.5 17.2 8.4 12.7 1.6 17.6 8 11.9 1.8 17.2 7.2 114 7 115 165 2.1 0 2.3 2.1 04/06/2007 03:40:00 11.8 1.5 14.9 7.2 11.9 1.5 14.9 7.6 11.2 1.6 15.6 6.1 120 6 119 165 2.1 0 2.3 1.8 04/06/2007 03:50:00 11.5 1.6 15.3 7.2 11.7 1.6 15.6 7.2 10.9 1.7 15.3 6.8 114 7 119 165 2.2 0 2.3 2.1 04/06/2007 04:00:00 11.9 1.4 16.4 8.4 12.2 1.5 16.4 8.8 11.4 1.6 15.6 7.6 109 6 116 165 2.3 0 2.6 2.1 04/06/2007 04:10:00 10.7 1.6 15.3 6.5 10.8 1.6 15.6 6.8 10.1 1.7 14.9 6.1 116 7 115 165 2.3 0 2.6 2.1 04/06/2007 04:20:00 12 1.6 16.1 7.6 12.2 1.7 16.4 8.4 11.3 1.7 16.1 7.6 113 6 116 165 2.3 0 2.6 2.1 04/06/2007 04:30:00 10.9 1.5 14.9 7.6 11.2 1.5 15.6 8 10.1 1.6 14.9 6.8 109 6 118 165 2.3 0 2.6 2.3 04/06/2007 04:40:00 11 1.6 14.5 6.8 11.3 1.6 14.9 7.2 10.4 1.7 14.5 6.8 106 8 111 165 2.3 0 2.6 2.3 04/06/2007 04:50:00 12.3 1.7 17.2 9.1 12.6 1.7 17.6 9.1 11.7 1.7 16.8 8.8 104 7 111 165 2.3 0 2.6 2.1 04/06/2007 05:00:00 12.5 1.7 16.8 8.8 12.8 1.7 16.8 8.8 11.9 1.8 16.4 6.8 106 7 108 165 2.3 0 2.6 2.1 04/06/2007 05:10:00 13.1 2 17.6 7.6 13.3 2 17.6 8.4 12.2 2.2 16.8 6.8 110 7 115 165 2.2 0 2.3 2.1 04/06/2007 05:20:00 12.1 1.4 15.3 8.8 12.4 1.5 16.1 8.8 11.5 1.5 15.6 8 105 7 105 165 2.2 0 2.6 2.1 04/06/2007 05:30:00 12.1 1.6 16.1 7.2 12.4 1.6 16.4 8 11.5 1.7 15.6 7.6 108 7 105 165 2.2 0 2.3 2.1 04/06/2007 05:40:00 10.6 1.2 13.3 6.5 10.9 1.2 13.3 6.5 10.2 1.2 13.7 6.1 114 8 113 165 2.3 0 2.6 2.1 04/06/2007 05:50:00 10.9 1.3 14.1 7.2 11.1 1.3 14.5 7.2 10.2 1.5 14.1 6.5 113 8 107 165 2.3 0 2.6 2.1 04/06/2007 06:00:00 10.6 1 14.1 8.4 10.8 1 14.5 8.8 10.1 1 13.3 7.2 110 5 112 165 2.3 0 2.6 2.3 04/06/2007 06:10:00 9.9 1.6 14.9 7.2 10.1 1.7 14.9 6.8 9.3 1.7 14.1 5.3 108 8 102 165 2.3 0 2.6 2.1 04/06/2007 06:20:00 11.4 1.1 14.5 9.1 11.6 1.1 14.1 8.8 10.9 1 13.7 8.4 106 5 105 165 2.4 0 2.6 2.3 04/06/2007 06:30:00 10.8 1.1 14.5 8 11.1 1.1 14.5 8 10 1.1 14.1 7.6 100 6 96 165 2.4 0 2.6 2.3 04/06/2007 06:40:00 13 1.5 16.4 8.8 13.3 1.5 16.8 8.8 12.4 1.6 16.4 8.4 98 7 93 165 2.5 0 2.8 2.3 04/06/2007 06:50:00 12.1 1.1 15.3 8.4 12.5 1.1 15.6 8.8 11.5 1.3 14.5 8.4 101 6 106 165 2.6 0 2.8 2.6 04/06/2007 07:00:00 11.8 1.1 14.5 8.8 12.1 1.1 14.9 9.1 11.1 1.2 13.7 8.4 95 6 99 165 2.6 0 2.8 2.6 04/06/2007 07:10:00 11.5 1.2 14.1 8.8 11.9 1.2 14.5 8.8 10.9 1.2 14.1 8.4 90 6 85 165 2.6 0 2.8 2.6 04/06/2007 07:20:00 13.4 1.2 16.8 9.5 13.7 1.2 16.8 9.5 12.8 1.3 16.8 9.1 86 5 82 165 2.7 0 2.8 2.6 04/06/2007 07:30:00 14.7 1.5 17.6 10.3 15 1.5 17.9 11.1 13.8 1.4 16.4 10.3 84 4 87 165 2.9 0 3 2.8 04/06/2007 07:40:00 14.7 1.4 17.6 10.3 15.1 1.4 17.6 10.7 14.1 1.3 17.6 9.5 84 5 87 165 2.9 0 3 2.8 04/06/2007 07:50:00 14.7 1.5 17.6 10.7 15 1.5 17.9 10.7 14.1 1.4 17.2 10.3 84 5 92 165 3 0 3.3 2.8 04/06/2007 08:00:00 15.4 1.2 17.9 11.8 15.7 1.2 18.3 12.2 14.7 1.2 17.6 11.5 85 5 91 165 3 0 3.3 2.8 04/06/2007 08:10:00 15.5 1.4 18.3 11.5 15.8 1.5 19.1 11.1 14.8 1.5 17.9 11.1 86 5 92 165 3 0 3.3 2.8 04/06/2007 08:20:00 15 1.3 18.3 11.8 15.4 1.3 18.7 11.8 14.4 1.3 18.7 11.5 86 5 90 165 3 0 3 2.8 04/06/2007 08:30:00 14.9 1.5 18.3 10.7 15.2 1.5 18.7 10.7 14.3 1.7 18.3 10.3 84 5 90 165 3 0 3.3 2.8 04/06/2007 08:40:00 15.8 1.3 19.1 11.5 16.1 1.4 19.1 12.2 15.2 1.5 18.3 10.7 88 5 87 165 3 0 3 2.8 04/06/2007 08:50:00 15.9 1.1 17.9 12.2 16.3 1.1 18.3 12.6 15.4 1.2 17.9 11.8 88 5 87 165 3 0 3.3 2.8 04/06/2007 09:00:00 16 1 18.3 12.2 16.4 1 18.7 12.6 15.4 1 17.6 12.2 88 4 92 165 3 0 3 2.8 04/06/2007 09:10:00 15.1 1.3 18.7 12.2 15.4 1.3 19.1 11.8 14.5 1.3 18.3 11.1 86 5 85 165 3 0 3.3 2.8 04/06/2007 09:20:00 15 1.5 17.9 9.9 15.3 1.5 18.3 10.3 14.5 1.5 18.3 9.5 86 5 85 165 2.9 0 3.3 2.8 04/06/2007 09:30:00 15.6 1.3 19.1 12.6 15.9 1.3 19.5 13 15 1.4 18.7 11.1 87 5 87 165 2.9 0 3 2.8 04/06/2007 09:40:00 15.2 1.6 18.7 11.1 15.5 1.7 19.5 11.1 14.5 1.7 19.1 9.9 85 6 88 165 2.9 0 3 2.8 04/06/2007 09:50:00 16 1.6 18.7 10.3 16.4 1.6 19.5 10.7 15.4 1.6 18.7 9.9 84 5 86 165 2.9 0 3 2.8 04/06/2007 10:00:00 15 1.6 18.7 11.1 15.3 1.7 19.5 11.1 14.4 1.5 18.7 10.3 83 6 85 165 2.9 0 3 2.8 04/06/2007 10:10:00 15 1.5 18.3 11.1 15.4 1.5 18.7 11.5 14.5 1.4 17.9 10.3 83 5 86 165 2.9 0 3 2.8 04/06/2007 10:20:00 13.8 1.6 17.6 9.1 14.1 1.7 18.3 9.1 13.3 1.5 16.8 9.5 81 6 96 165 2.9 0 3 2.6 04/06/2007 10:30:00 13.1 1.5 16.8 9.5 13.4 1.6 17.6 9.5 12.6 1.4 16.8 9.5 79 7 83 165 2.8 0 3 2.6 04/06/2007 10:40:00 12.1 1.8 16.4 8 12.4 1.9 16.4 8 11.8 1.8 16.1 7.6 78 8 78 165 2.8 0 3 2.6 04/06/2007 10:50:00 11.2 1.3 16.8 8 11.5 1.3 17.2 8.4 11.1 1.3 15.6 8 71 7 71 165 2.8 0 3 2.6 04/06/2007 11:00:00 10.3 1.3 13.7 7.6 10.5 1.4 14.5 7.2 10 1.3 14.1 6.5 70 8 72 165 2.8 0 2.8 2.8 04/06/2007 11:10:00 10.4 1.3 13.7 6.5 10.6 1.4 14.5 6.8 10.1 1.3 14.1 6.8 67 9 61 165 2.9 0 3 2.8 04/06/2007 11:20:00 8.9 1.4 12.6 5.7 9 1.5 13 5.7 8.5 1.4 13 6.1 61 10 50 165 2.9 0 3 2.8 04/06/2007 11:30:00 8.2 1.7 12.6 4.6 8.4 1.7 12.6 4.9 8 1.5 13 3.8 55 9 73 165 3 0 3.3 2.8 04/06/2007 11:40:00 10 1.7 16.1 6.8 10.1 1.7 16.4 6.8 9.6 1.7 14.5 6.1 52 10 53 165 3 0 3.3 2.8 04/06/2007 11:50:00 11.1 1.5 14.9 6.8 11.1 1.7 14.9 6.8 10.8 1.7 14.9 6.5 57 9 65 165 2.8 0 3 2.6 04/06/2007 12:00:00 10.4 1.6 13.7 5.7 10.6 1.7 14.1 5.7 10.1 1.6 13.7 5.3 55 10 65 165 2.6 0 2.8 2.6 04/06/2007 12:10:00 9.9 1.7 15.6 5.7 9.9 1.7 15.3 5.7 9.6 1.6 15.3 6.5 45 9 43 165 2.5 0 2.8 2.3 04/06/2007 12:20:00 8.9 1.7 14.9 5.7 9 1.7 14.9 6.1 8.5 1.7 14.9 5.3 42 12 53 165 2.5 0 2.8 2.3 04/06/2007 12:30:00 11.1 2.2 16.1 6.1 11.2 2.2 16.4 6.1 10.8 1.9 15.3 7.2 44 10 42 165 2.4 0 2.6 2.1 04/06/2007 12:40:00 10.2 1.9 14.9 5.7 10.2 1.9 14.9 5.7 9.9 2 14.9 4.9 40 10 42 165 2.4 0.1 2.6 2.1 04/06/2007 12:50:00 11 2.1 17.2 6.5 10.9 2.1 17.6 6.1 10.6 2.1 17.6 5.7 37 11 41 165 2.4 0 2.6 2.3 04/06/2007 13:00:00 11.1 1.8 15.6 6.1 11.1 1.9 16.1 5.7 11 1.7 16.4 6.8 39 10 60 165 2.2 0 2.6 2.1 04/06/2007 13:10:00 11.7 2.2 17.2 6.8 11.6 2.2 16.8 6.5 11.5 2.3 16.8 6.8 35 8 43 165 2.3 0 2.6 2.1 04/06/2007 13:20:00 11.4 1.7 15.6 6.8 11.3 1.7 15.6 6.8 11.4 1.7 16.4 7.2 33 8 29 165 2.1 0 2.3 1.8 04/06/2007 13:30:00 12 1.7 17.2 7.2 12 1.7 17.2 7.6 11.8 1.8 17.2 7.2 30 8 37 165 2.1 0 2.3 1.8 04/06/2007 13:40:00 12.6 1.8 16.4 8.4 12.4 1.9 16.4 7.6 12.3 1.9 16.4 7.6 26 8 28 165 2 0.1 2.3 1.8 04/06/2007 13:50:00 12.6 1.5 16.1 8.8 12.4 1.5 16.1 8.4 12.2 1.5 15.6 8 28 7 26 165 1.9 0 2.1 1.8 04/06/2007 14:00:00 13.5 1.7 17.2 8 13 1.7 16.8 8 13.4 1.6 17.2 9.1 23 7 31 165 1.9 0 2.1 1.6 04/06/2007 14:10:00 14.3 1.9 18.3 9.5 13 2.8 17.9 5.7 14 2.1 18.3 9.1 19 8 28 165 1.7 0 1.8 1.6 04/06/2007 14:20:00 12.7 1.3 15.6 9.1 10.2 1.8 14.9 5.7 12.4 1.3 15.6 8.4 12 6 10 165 1.7 0 1.8 1.6 04/06/2007 14:30:00 13.7 1.4 16.8 10.3 11.5 1.8 16.4 6.8 13.5 1.5 16.8 9.1 13 6 16 165 1.6 0 1.6 1.4 04/06/2007 14:40:00 13.6 1.3 16.4 9.5 11.8 1.7 16.1 7.6 13.3 1.3 16.8 9.9 14 5 16 165 1.5 0 1.6 1.4 04/06/2007 14:50:00 12.6 1.3 16.8 9.9 11.1 1.5 16.4 6.8 12.8 1.2 16.1 9.9 13 4 21 165 1.5 0 1.6 1.4 04/06/2007 15:00:00 11.7 1.1 14.1 8.8 9.7 1.6 13.3 5.7 11.7 1.1 14.9 8.8 10 6 16 165 1.5 0 1.6 1.4 04/06/2007 15:10:00 11.4 1.3 15.3 8 8.6 1.7 14.5 5.7 11.2 1.3 15.3 8.8 357 8 357 165 1.5 0 1.6 1.4 04/06/2007 15:20:00 13 2.5 19.9 8.4 10.8 3.1 19.1 5.3 12.6 2.3 19.5 8.4 351 9 356 165 1.6 0 1.8 1.4 04/06/2007 15:30:00 16 2.5 23.3 9.5 13.1 2.3 20.2 8.4 15.4 2.8 21.8 8.4 349 9 351 165 1.9 0.1 2.3 1.6 04/06/2007 15:40:00 17.3 2 22.9 12.2 14.2 2.5 21.4 8.8 16.9 2.1 23.7 11.1 350 8 356 165 2 0 2.3 1.8 04/06/2007 15:50:00 18 2 22.9 13.7 15.1 2.3 20.6 9.9 17.2 2.1 22.1 11.5 347 8 356 165 1.9 0 1.8 1.6 04/06/2007 16:00:00 19.9 3.1 27.9 12.6 16.6 3.3 27.1 9.9 19.3 3.2 27.9 11.8 350 9 349 165 1.8 0 1.8 1.6 04/06/2007 16:10:00 21.8 2.8 29.1 15.6 18 2.8 26.8 11.5 21.4 2.9 28.3 14.9 350 8 330 165 1.9 0 2.3 1.8 04/06/2007 16:20:00 19.1 1.8 26 14.9 16.9 2.3 21.8 10.7 18.2 2 24.8 14.1 349 7 359 165 1.9 0 2.1 1.8 04/06/2007 16:30:00 16.4 1.9 22.6 11.8 14.2 2.2 21.4 9.1 15.7 2.2 22.1 10.3 349 9 353 165 1.8 0 1.8 1.6 04/06/2007 16:40:00 17.5 1.8 22.6 13.3 14.1 2.1 19.5 9.1 17.1 2.2 23.7 11.8 355 9 3 165 1.9 0 2.1 1.8 04/06/2007 16:50:00 13.6 2.5 20.2 9.1 13.3 2.4 20.6 8.8 13 2.4 18.7 8.8 333 12 337 165 1.7 0 1.8 1.4 04/06/2007 17:00:00 10.6 1.8 16.8 6.5 10.7 1.8 16.4 6.5 9.7 1.8 15.3 5.3 330 11 327 165 1.5 0 1.6 1.4 04/06/2007 17:10:00 11.9 1.5 17.2 8.8 12 1.4 17.2 9.1 11.3 1.5 16.4 7.6 323 8 322 165 1.5 0 1.6 1.4 04/06/2007 17:20:00 12.7 1.1 16.4 10.3 12.8 1.1 16.1 10.3 12.1 1.1 14.9 9.5 325 7 333 165 1.4 0 1.6 1.4 04/06/2007 17:30:00 11.6 1.3 15.3 8.4 11.7 1.3 15.3 8.4 11 1.3 14.1 7.6 328 8 328 165 1.4 0 1.6 1.4 04/06/2007 17:40:00 12.7 1.5 16.1 8.4 12.7 1.4 16.1 8.4 12 1.7 16.1 7.2 320 7 321 165 1.4 0 1.6 1.4 04/06/2007 17:50:00 12.7 1.2 16.1 8.8 12.7 1.2 16.4 9.5 11.8 1.4 16.1 8.4 321 9 313 165 1.5 0 1.6 1.4 04/06/2007 18:00:00 11.6 1.2 14.5 8.8 11.7 1.2 14.5 8.4 10.9 1.3 14.9 8 326 8 318 165 1.5 0 1.6 1.4 04/06/2007 18:10:00 13.2 1.7 18.3 8.4 12.9 1.7 17.6 8 12.7 1.7 18.7 8.4 334 10 4 165 1.5 0 1.6 1.4 04/06/2007 18:20:00 11.8 1.1 14.9 8.4 11.9 1.2 15.3 8.4 11.2 1.2 14.9 7.6 329 13 333 165 1.5 0 1.6 1.4 04/06/2007 18:30:00 12.2 1.6 17.9 7.6 12.3 1.6 17.6 8 11.7 1.6 17.2 7.2 330 11 336 165 1.7 0 1.8 1.4 04/06/2007 18:40:00 12.6 1.7 17.6 8.8 12.6 1.7 17.9 9.1 12.2 1.7 17.2 8 332 8 322 165 1.7 0 1.8 1.6 04/06/2007 18:50:00 12.5 1.8 18.3 7.6 12.5 1.9 18.7 7.6 12.4 2 18.3 7.2 340 6 322 165 1.7 0 1.8 1.4 04/06/2007 19:00:00 13.2 1.9 18.7 7.2 13.2 1.9 19.1 7.6 12.9 2 19.1 7.6 329 8 329 165 1.8 0 1.8 1.6 04/06/2007 19:10:00 13.4 1.9 17.9 8.4 13.3 1.9 17.9 8.4 13 1.8 17.6 8.4 316 13 328 165 1.7 0 1.8 1.6 04/06/2007 19:20:00 13.6 2 20.6 7.6 13.4 2.1 21 8 13.2 2 19.1 7.2 314 11 341 165 1.8 0.1 2.1 1.6 04/06/2007 19:30:00 12.8 1.6 16.8 8.8 12.7 1.6 16.8 8.8 12.5 1.7 16.8 8.8 326 9 324 165 1.9 0 2.3 1.8 04/06/2007 19:40:00 13.6 2.1 19.9 9.5 13.5 2 19.5 9.1 13.3 2.3 18.3 8.4 330 10 334 165 2 0 2.3 1.8 04/06/2007 19:50:00 14.9 1.4 18.3 10.7 14.7 1.4 17.9 10.7 14.7 1.5 18.7 10.3 332 6 329 165 2.1 0 2.3 1.8 04/06/2007 20:00:00 11.2 1.3 15.3 7.6 11.1 1.2 15.6 8 11 1.5 16.1 7.6 328 10 338 165 2 0.1 2.3 1.8 04/06/2007 20:10:00 8.8 1.1 11.8 5.3 8.9 1.1 11.8 5.3 8.2 1.2 11.5 4.9 316 10 319 165 1.7 0 1.8 1.6 04/06/2007 20:20:00 8.2 1.6 12.6 4.2 8.5 1.6 13 4.6 6.8 1.6 12.2 3.8 298 11 292 165 1.6 0 1.6 1.4 04/06/2007 20:30:00 11.2 1.3 14.1 6.8 11.5 1.3 14.5 7.2 9.6 1.6 13.3 5.3 294 5 296 165 1.5 0 1.6 1.4 04/06/2007 20:40:00 11.5 1.1 13.3 8 11.8 1.2 14.1 8 8.8 1 11.8 5.7 296 0 296 165 1.5 0 1.6 1.4 04/06/2007 20:50:00 11 1.1 13 7.2 11.3 1.2 13.7 7.6 9 1.1 11.5 5.3 296 0 296 165 1.5 0 1.6 1.4 04/06/2007 21:00:00 10 1.1 12.2 6.8 10.3 1.1 12.6 7.2 8.3 1.1 10.7 5.7 296 0 296 165 1.4 0 1.6 1.4 04/06/2007 21:10:00 7.9 0.8 9.9 5.7 8.3 0.9 10.3 6.1 6.6 0.9 9.5 4.6 296 0 296 165 1.3 0 1.6 1.1 04/06/2007 21:20:00 8.5 1 10.7 6.5 9 1 11.1 6.8 7.6 1.7 11.1 4.2 296 0 296 165 1.3 0 1.4 1.1 04/06/2007 21:30:00 9.1 1 10.7 6.8 9.7 0.9 11.5 7.2 9.1 0.9 11.1 6.5 296 0 296 165 1.3 0 1.4 1.1 04/06/2007 21:40:00 6.2 1.1 8.4 2.3 7.5 1 9.5 4.6 6.7 1 9.1 4.2 296 0 296 165 1.3 0 1.4 1.1 04/06/2007 21:50:00 4.3 0.9 6.8 1.5 5.8 0.9 8 3.4 5.4 0.9 7.6 3.4 296 0 296 165 1.4 0 1.4 1.4 04/06/2007 22:00:00 0.4 0 1.1 0.4 3.7 0.6 5.7 1.9 3.7 0.5 5.3 2.3 296 0 296 165 1.4 0 1.6 1.4 04/06/2007 22:10:00 0.4 0 0.4 0.4 3.4 0.6 4.9 1.9 3.3 0.5 4.6 2.3 296 0 165 165 1.4 0 1.6 1.4 04/06/2007 22:20:00 0.4 0 0.4 0.4 4.1 1.4 6.8 1.1 3.8 1.4 6.5 1.1 296 0 165 165 1.3 0 1.4 1.1 04/06/2007 22:30:00 0.4 0 0.4 0.4 5.7 1 8.4 3 5.6 1 8.4 3.4 296 0 165 165 1.3 0 1.4 1.1 04/06/2007 22:40:00 0.4 0 0.4 0.4 6.7 0.6 8.4 4.9 6.7 0.6 8 4.9 296 0 165 165 1.2 0 1.4 1.1 04/06/2007 22:50:00 0.4 0 0.4 0.4 7.7 1.2 10.7 4.6 7.4 1.2 10.3 4.6 296 0 165 165 1.2 0 1.4 1.1 04/06/2007 23:00:00 0.4 0 0.4 0.4 9 1.2 12.6 6.5 8.9 1.1 11.8 6.5 296 0 165 165 1.2 0 1.4 1.1 04/06/2007 23:10:00 0.4 0 0.4 0.4 9.2 1.1 12.2 6.5 9.2 1 11.5 6.5 296 0 165 165 1.2 0 1.4 0.9 04/06/2007 23:20:00 0.4 0 0.4 0.4 10 1.4 13.3 6.8 9.9 1.3 13.3 6.5 296 0 165 165 1.2 0 1.4 0.9 04/06/2007 23:30:00 0.4 0 0.4 0.4 12.8 1.6 16.1 8.8 13 1.8 17.2 9.1 296 0 165 165 1.4 0 1.6 1.4 04/06/2007 23:40:00 0.4 0 0.4 0.4 12.7 1.1 14.5 9.9 13.1 1.2 15.6 10.3 296 0 165 165 1.4 0 1.6 1.4 04/06/2007 23:50:00 0.4 0 0.4 0.4 12.3 1.2 14.9 9.1 12.5 1.4 15.6 8.8 296 0 165 165 1.4 0 1.6 1.1 04/07/2007 00:00:00 0.4 0 0.4 0.4 12.2 1.6 15.6 7.6 12.4 1.7 16.4 7.6 295 0 165 165 1.4 0 1.6 1.4 04/07/2007 00:10:00 0.4 0 0.4 0.4 13.3 1.2 16.4 9.1 13.7 1.3 16.8 10.3 254 49 165 165 1.5 0 1.6 1.4 04/07/2007 00:20:00 0.4 0 0.4 0.4 14.6 1 16.8 11.8 15 1.2 17.9 11.5 193 5 165 165 1.6 0 1.6 1.4 04/07/2007 00:30:00 0.4 0 0.4 0.4 11.2 1.5 14.1 8 11.7 1.7 15.3 8 195 5 165 165 1.6 0 1.6 1.4 04/07/2007 00:40:00 0.4 0 0.4 0.4 10 0.8 12.6 8 10.3 1 13.3 7.6 186 8 165 165 1.6 0 1.6 1.4 04/07/2007 00:50:00 0.4 0 0.4 0.4 9.1 0.7 11.1 7.2 9.4 0.8 11.5 7.2 180 7 165 165 1.6 0 1.6 1.4 04/07/2007 01:00:00 0.4 0 0.4 0.4 11.4 1.2 13.3 8.8 12 1.2 14.1 9.1 169 13 165 165 1.6 0 1.8 1.4 04/07/2007 01:10:00 0.4 0 0.4 0.4 13.8 0.8 15.6 11.5 14.2 1 16.1 11.5 156 32 165 165 1.5 0 1.6 1.4 04/07/2007 01:20:00 0.4 0 0.4 0.4 15.4 0.7 17.2 12.6 15.7 0.9 17.6 13.3 167 22 165 165 1.5 0 1.6 1.4 04/07/2007 01:30:00 0.4 0 0.4 0.4 15 0.5 16.1 13.7 15.4 0.6 16.8 13.7 157 35 165 165 1.5 0 1.6 1.4 04/07/2007 01:40:00 0.4 0 0.4 0.4 14.5 0.7 16.1 12.6 15 0.7 16.8 13 151 41 165 165 1.5 0 1.6 1.4 04/07/2007 01:50:00 3.2 6.1 17.6 0.4 14.7 1 17.2 12.6 15.2 1 17.6 12.6 148 45 174 165 1.5 0 1.6 1.4 04/07/2007 02:00:00 16.5 1.1 19.5 14.1 16 1 19.5 13.7 16.6 1.1 19.5 13.7 167 27 169 165 1.4 0 1.6 1.4 04/07/2007 02:10:00 15.7 0.9 19.1 13.7 15.3 0.9 17.9 13 15.6 0.9 18.3 13 152 41 179 165 1.4 0 1.6 1.4 04/07/2007 02:20:00 15.2 1 17.9 12.6 14.8 0.9 17.2 12.2 15.2 0.9 17.6 12.6 158 35 174 165 1.4 0 1.6 1.4 04/07/2007 02:30:00 15.3 1 17.9 13 14.8 1.1 17.6 12.6 15.2 1.1 17.9 12.6 159 38 168 165 1.4 0 1.6 1.1 04/07/2007 02:40:00 14.3 1.7 18.3 11.1 13.6 1.7 18.3 10.3 14 1.7 18.3 10.7 167 26 168 165 1.2 0 1.4 0.9 04/07/2007 02:50:00 15.2 1.4 18.7 11.5 14.6 1.2 18.3 11.5 15 1.4 18.7 11.1 163 30 176 165 1.1 0 1.4 0.9 04/07/2007 03:00:00 12.9 0.9 15.3 10.7 12.5 0.8 14.9 10.3 12.7 0.9 15.3 10.3 163 29 171 165 1.1 0 1.4 0.9 04/07/2007 03:10:00 12.2 1.2 15.3 9.1 11.7 1.2 14.5 9.1 11.9 1.2 15.3 9.5 167 26 169 165 1.2 0 1.4 0.9 04/07/2007 03:20:00 14.9 1.5 17.9 10.7 14.2 1.3 17.6 10.7 14.6 1.5 17.9 10.7 168 22 165 165 1.1 0 1.4 0.9 04/07/2007 03:30:00 15.3 1.3 17.9 12.2 14.6 1.2 17.9 11.5 15 1.3 18.3 11.5 169 28 100 165 1.1 0 1.4 0.9 04/07/2007 03:40:00 16 1.6 19.5 11.8 15.4 1.5 19.1 11.5 15.7 1.6 20.2 11.8 162 36 179 165 1.1 0 1.4 0.9 04/07/2007 03:50:00 14.7 1 16.8 11.5 14.1 1 16.4 10.7 14.5 1.1 17.2 11.1 160 33 182 165 1 0 1.1 0.9 04/07/2007 04:00:00 14.2 1.2 16.8 11.1 13.9 1.1 16.4 11.1 13.9 1.5 16.8 10.7 149 39 178 165 1.1 0 1.4 0.9 04/07/2007 04:10:00 13.5 0.9 15.3 10.7 13.3 0.9 14.9 10.3 13.1 0.9 15.3 10.7 132 49 219 165 1.1 0 1.4 0.9 04/07/2007 04:20:00 13.7 0.6 15.3 12.2 13.5 0.6 14.9 11.5 13.5 0.7 14.9 11.8 144 47 177 165 1.1 0 1.4 0.9 04/07/2007 04:30:00 12.9 0.9 14.9 10.3 12.6 0.9 14.5 9.9 12.7 1 14.5 10.3 157 36 173 165 1.1 0 1.4 0.9 04/07/2007 04:40:00 10.9 0.5 12.2 9.1 10.4 0.5 11.8 8.8 10.6 0.5 12.2 9.1 169 15 172 165 1.1 0 1.4 0.9 04/07/2007 04:50:00 8.7 0.7 10.3 7.2 8.4 0.6 9.9 6.8 8.7 0.7 10.7 6.5 145 35 167 165 1.1 0 1.4 0.9 04/07/2007 05:00:00 6.8 0.7 8.4 4.9 6.8 0.6 8 4.9 6.9 0.7 8.4 4.9 139 27 162 165 1.1 0 1.4 0.9 04/07/2007 05:10:00 5.2 0.5 6.5 4.2 5.6 0.4 6.5 4.6 5.6 0.4 6.5 4.6 150 11 116 165 1.1 0 1.4 0.9 04/07/2007 05:20:00 7.3 0.9 9.1 4.9 7.8 0.8 9.9 5.7 7.7 0.8 9.5 5.7 146 5 145 165 1.1 0 1.4 0.9 04/07/2007 05:30:00 6.6 0.8 8.4 4.9 7.1 0.7 8.4 5.7 7.2 0.8 8.8 5.7 148 5 138 165 1.2 0 1.4 0.9 04/07/2007 05:40:00 7.1 0.6 8.4 5.7 8 0.5 9.1 6.5 7.9 0.5 9.5 6.5 144 4 142 165 1.3 0 1.6 1.1 04/07/2007 05:50:00 6.8 0.6 9.1 5.7 8 0.6 9.9 6.8 7.8 0.6 9.5 6.5 143 5 145 165 1.4 0 1.6 1.4 04/07/2007 06:00:00 8.6 1.6 12.6 4.9 9.9 1.5 13.7 6.5 9.5 1.4 13 6.5 138 7 138 165 1.5 0 1.6 1.4 04/07/2007 06:10:00 11.2 1.1 14.5 8.4 12.2 1.2 15.6 9.5 11.9 1.1 14.1 9.1 139 6 136 165 1.5 0 1.6 1.4 04/07/2007 06:20:00 12 0.8 15.3 9.9 13 0.8 15.6 10.3 12.8 0.8 14.9 10.7 141 9 145 165 1.6 0 1.6 1.4 04/07/2007 06:30:00 11.7 0.8 13.7 9.5 12.6 0.8 14.5 10.3 12.4 0.8 14.1 9.9 141 6 146 165 1.7 0 1.8 1.4 04/07/2007 06:40:00 11 1 13.3 8.8 11.8 0.9 13.7 9.5 11.7 0.8 13.7 9.5 143 6 156 165 1.8 0 1.8 1.6 04/07/2007 06:50:00 10.9 0.7 13 8.8 11.7 0.7 13.7 9.1 11.5 0.7 13.3 8.8 142 5 143 165 1.9 0 1.8 1.8 04/07/2007 07:00:00 10.8 1.1 13.3 8.4 11.5 1.1 14.5 8.8 10.5 1.4 13.7 7.6 140 6 146 165 1.9 0 1.8 1.6 04/07/2007 07:10:00 12 1.1 15.6 9.1 12 1.2 15.6 9.1 11.7 1.3 14.5 8 138 8 142 165 1.9 0 2.1 1.8 04/07/2007 07:20:00 13.4 1.5 17.2 9.9 13.1 1.6 17.2 9.5 13.2 1.5 17.2 9.5 138 7 138 165 1.9 0 2.1 1.8 04/07/2007 07:30:00 14 1.5 17.6 9.5 14 1.5 17.6 9.9 13.6 1.6 17.6 9.1 133 9 139 165 2 0 2.3 1.8 04/07/2007 07:40:00 14.3 1.1 17.2 10.7 14.3 1.1 17.2 10.7 13.9 1.3 17.6 10.3 131 8 119 165 2.1 0 2.3 1.8 04/07/2007 07:50:00 13.8 1.3 16.8 9.9 13.8 1.3 17.2 9.5 13.4 1.5 16.4 9.1 128 7 135 165 2.1 0 2.3 1.8 04/07/2007 08:00:00 13 1.3 16.1 9.9 13 1.3 16.1 9.9 12.6 1.3 16.4 9.1 129 9 136 165 2.1 0 2.3 1.8 04/07/2007 08:10:00 13.6 1.1 17.6 10.3 13.7 1.1 17.6 9.9 13.2 1.1 16.8 10.3 127 7 122 165 2.1 0 2.3 1.8 04/07/2007 08:20:00 13.1 1.2 16.1 10.3 13.2 1.2 16.1 10.3 12.6 1.2 15.6 9.1 126 7 122 165 2.1 0 2.3 1.8 04/07/2007 08:30:00 14.4 1.1 18.7 11.5 14.5 1.1 18.7 11.8 14.1 1.3 17.9 9.5 133 8 137 165 2 0.1 2.3 1.8 04/07/2007 08:40:00 13.2 1.1 16.1 8 13.2 1.1 16.4 8.8 12.7 1.2 15.6 8.8 131 8 123 165 2 0 2.3 1.8 04/07/2007 08:50:00 13.6 1.1 16.1 9.5 13.7 1.2 16.4 9.9 13.3 1.2 16.4 10.3 122 6 115 165 2 0.1 2.3 1.8 04/07/2007 09:00:00 13.4 1.1 16.4 9.9 13.6 1.1 16.8 9.5 13.1 1.2 16.4 8.8 123 5 122 165 1.8 0 1.8 1.6 04/07/2007 09:10:00 12.8 0.9 15.6 10.3 12.9 1 16.1 10.3 12.6 0.9 14.9 8.8 125 7 125 165 1.9 0 1.8 1.8 04/07/2007 09:20:00 12.2 1 15.3 9.1 12.4 1 15.6 9.5 11.9 1.2 15.3 8.8 123 6 122 165 1.9 0 2.1 1.8 04/07/2007 09:30:00 13.2 1.4 16.8 8.8 13.4 1.4 17.2 9.1 12.8 1.3 16.4 8.8 123 8 104 165 2 0 2.3 1.8 04/07/2007 09:40:00 13.6 1 17.2 11.1 13.7 1 17.6 11.1 13.2 1.1 16.4 9.5 121 6 113 165 2.1 0 2.3 1.8 04/07/2007 09:50:00 13 1.5 17.2 9.1 13.2 1.5 17.2 9.5 12.6 1.5 16.4 8.8 119 6 122 165 2.1 0 2.3 1.8 04/07/2007 10:00:00 13.1 1.3 16.1 9.9 13.3 1.3 16.4 9.5 12.7 1.5 16.8 7.2 120 7 118 165 2.1 0 2.3 1.8 04/07/2007 10:10:00 13.9 1.4 19.1 9.5 14 1.4 18.7 9.9 13.3 1.5 17.6 8.4 119 7 120 165 2.1 0 2.3 1.8 04/07/2007 10:20:00 13.8 1.8 19.5 8.4 13.9 1.9 19.9 8.8 13.5 1.8 18.3 8.4 122 8 114 165 2.1 0 2.3 1.8 04/07/2007 10:30:00 13.1 1.5 16.8 8.4 13.3 1.5 16.8 8 12.5 1.5 17.2 8 118 7 119 165 2.1 0 2.3 1.8 04/07/2007 10:40:00 13.6 1.2 16.4 10.3 13.8 1.2 16.8 10.7 13 1.4 16.4 8.8 116 7 119 165 2 0 2.3 1.8 04/07/2007 10:50:00 13.6 1.5 17.9 8.8 13.8 1.4 18.3 9.5 13 1.6 17.6 8.8 116 6 111 165 2.1 0 2.3 1.8 04/07/2007 11:00:00 13.3 2 17.9 8 13.5 2 18.3 7.6 12.7 2 17.6 6.8 116 7 113 165 2.1 0 2.3 1.8 04/07/2007 11:10:00 13.6 1.7 17.6 9.1 13.8 1.7 18.3 8.8 12.9 1.7 17.6 8.4 114 7 99 165 2.1 0 2.3 1.8 04/07/2007 11:20:00 14.5 1.7 18.3 9.5 14.7 1.7 19.1 9.5 13.6 1.9 17.2 6.8 112 7 124 165 2.1 0 2.3 1.8 04/07/2007 11:30:00 15.4 1.5 19.1 11.8 15.6 1.5 19.9 11.5 14.8 1.7 19.9 10.7 111 7 109 165 2.1 0 2.3 1.8 04/07/2007 11:40:00 13.7 1.6 17.6 9.5 14 1.6 17.9 8.8 13.2 1.7 17.9 8.8 115 6 110 165 2.2 0 2.3 2.1 04/07/2007 11:50:00 13.5 1.5 16.8 9.9 13.7 1.5 17.2 9.9 12.9 1.6 16.1 8.8 113 6 110 165 2.3 0 2.3 2.1 04/07/2007 12:00:00 13.2 1.1 16.4 9.1 13.4 1.1 16.4 9.5 12.7 1.2 16.1 9.1 112 7 106 165 2.3 0 2.3 2.1 04/07/2007 12:10:00 13.2 1.2 16.8 9.9 13.4 1.3 17.2 9.5 12.6 1.4 16.8 8.8 110 7 102 165 2.3 0 2.6 2.1 04/07/2007 12:20:00 13.4 1.2 16.8 9.9 13.7 1.2 16.8 10.3 12.7 1.3 15.6 9.1 108 6 112 165 2.3 0 2.6 2.1 04/07/2007 12:30:00 13.8 1.4 16.8 8.8 14 1.4 17.2 9.1 13.2 1.4 16.1 9.1 105 6 102 165 2.3 0 2.6 2.3 04/07/2007 12:40:00 13.6 1.1 16.1 10.7 13.9 1.1 16.4 10.7 13 1.3 16.4 8.8 105 6 102 165 2.4 0 2.6 1.8 04/07/2007 12:50:00 13.7 1.1 16.4 10.7 13.9 1.1 16.8 11.5 13 1.2 16.1 9.1 108 6 109 165 2.4 0.1 2.6 1.8 04/07/2007 13:00:00 13.2 1.3 17.2 9.9 13.5 1.4 17.9 10.3 12.5 1.6 17.2 8.8 109 6 114 165 2.5 0.1 2.8 1.8 04/07/2007 13:10:00 14.2 1.2 16.8 10.7 14.5 1.2 17.2 11.1 13.6 1.5 16.8 9.5 108 5 115 165 2.4 0.1 2.6 1.8 04/07/2007 13:20:00 14.2 1.2 17.9 10.7 14.5 1.2 17.9 10.7 13.7 1.3 16.8 9.9 107 6 108 165 2.4 0.1 2.8 1.8 04/07/2007 13:30:00 14.1 1.5 17.6 9.1 14.3 1.5 17.9 9.1 13.6 1.7 18.3 8 109 5 106 165 2.4 0.1 2.8 1.8 04/07/2007 13:40:00 13.8 1.5 17.2 9.1 14 1.5 17.2 9.9 13.1 1.7 17.2 7.6 107 7 106 165 2.4 0.1 2.8 1.8 04/07/2007 13:50:00 14.1 1.2 17.2 10.7 14.4 1.2 17.6 10.7 13.6 1.3 17.2 9.5 105 7 110 165 2.4 0.1 2.6 1.8 04/07/2007 14:00:00 13.4 1.5 16.4 9.5 13.8 1.5 16.8 9.5 12.7 1.5 16.8 8.8 106 6 102 165 2.4 0.1 2.8 1.8 04/07/2007 14:10:00 13 1.2 15.3 9.1 13.3 1.3 16.1 9.5 12.4 1.4 15.3 8.4 105 7 104 165 2.5 0.1 2.8 1.8 04/07/2007 14:20:00 12.4 1.5 16.8 8 12.7 1.5 16.8 8 11.8 1.5 15.6 7.6 98 6 99 165 2.6 0 2.8 1.8 04/07/2007 14:30:00 13.8 1.3 16.8 10.3 14.1 1.3 17.6 10.3 13.3 1.4 16.8 9.9 96 7 95 165 2.5 0 2.8 2.3 04/07/2007 14:40:00 13.8 1.2 16.4 10.3 14.1 1.2 16.8 10.3 13.1 1.4 16.4 9.5 96 6 105 165 2.5 0 2.8 2.3 04/07/2007 14:50:00 13.9 1.3 16.4 10.3 14.2 1.3 17.2 10.3 13.2 1.4 16.1 9.5 93 6 99 165 2.5 0 2.8 2.3 04/07/2007 15:00:00 14.7 1.2 17.6 11.1 15.1 1.3 17.6 11.1 13.9 1.4 17.2 9.9 90 6 95 165 2.5 0 2.8 2.3 04/07/2007 15:10:00 15 1.3 17.6 11.5 15.3 1.3 17.6 11.5 14.1 1.4 17.6 9.5 90 5 92 165 2.5 0 2.8 2.3 04/07/2007 15:20:00 16.1 1 17.9 12.6 16.4 1 18.3 12.6 15.1 1.3 17.6 11.5 89 4 78 165 2.5 0 2.8 2.3 04/07/2007 15:30:00 15.4 1.3 18.3 11.5 15.8 1.4 19.1 12.2 14.8 1.4 17.6 11.1 89 6 92 165 2.5 0 2.8 2.3 04/07/2007 15:40:00 15.8 1.2 18.7 11.8 16.2 1.2 18.7 11.5 15.2 1.2 17.9 11.8 88 4 84 165 2.5 0 2.8 2.3 04/07/2007 15:50:00 16.1 1.1 18.3 12.6 16.5 1.1 18.7 13 15.5 1.2 18.3 12.2 88 5 91 165 2.4 0 2.8 2.3 04/07/2007 16:00:00 15.8 1.3 18.3 12.2 16.2 1.3 19.1 12.2 15.3 1.4 18.7 11.5 88 5 87 165 2.4 0 2.6 2.3 04/07/2007 16:10:00 15.4 1.5 19.5 10.3 15.8 1.5 19.1 11.1 14.9 1.5 18.7 10.3 88 6 90 165 2.4 0 2.6 2.3 04/07/2007 16:20:00 13.9 1.4 16.8 10.3 14.3 1.5 17.6 10.7 13.6 1.5 17.2 9.9 85 6 92 165 2.3 0 2.6 2.1 04/07/2007 16:30:00 13.5 1.4 16.4 9.9 13.9 1.5 17.2 9.9 13 1.4 16.1 9.5 80 7 78 165 2.1 0 2.3 1.8 04/07/2007 16:40:00 14.1 1.5 18.3 9.9 14.4 1.6 18.7 9.9 13.7 1.5 17.6 9.9 78 7 78 165 2.3 0 2.6 1.8 04/07/2007 16:50:00 14.1 1.6 18.3 10.3 14.4 1.7 18.3 10.3 13.6 1.6 17.6 9.5 78 6 85 165 2.3 0 2.6 1.8 04/07/2007 17:00:00 13.8 1.7 18.7 8.8 14.1 1.8 18.7 9.1 13.5 1.8 17.6 8.8 77 7 78 165 2.4 0.1 2.6 1.8 04/07/2007 17:10:00 14.6 1.6 18.7 10.3 14.9 1.7 19.5 10.7 14.1 1.6 18.7 10.3 78 7 81 165 2.4 0.1 2.6 1.8 04/07/2007 17:20:00 14.3 1.7 18.3 9.9 14.6 1.7 18.3 9.9 13.9 1.7 18.3 9.9 78 7 84 165 2.4 0.1 2.6 1.8 04/07/2007 17:30:00 14.2 1.6 18.3 10.7 14.5 1.7 18.3 10.7 13.5 1.6 17.2 9.9 80 7 85 165 2.4 0.1 2.6 1.8 04/07/2007 17:40:00 14.6 1.7 18.7 11.1 14.9 1.8 19.5 10.7 14 1.7 18.7 10.3 80 8 84 165 2.4 0.1 2.6 1.8 04/07/2007 17:50:00 14.5 1.7 19.9 9.9 14.8 1.7 20.2 10.3 14 1.7 19.1 9.9 76 8 88 165 2.4 0.1 2.6 1.8 04/07/2007 18:00:00 14.1 2 19.9 9.9 14.4 2.1 20.2 9.9 13.7 2 19.5 9.5 77 7 78 165 2.3 0.1 2.8 1.6 04/07/2007 18:10:00 14.5 1.9 19.9 10.7 14.8 2 20.2 10.7 14.1 2 19.5 9.9 77 7 72 165 2.3 0 2.6 1.8 04/07/2007 18:20:00 14.7 1.6 18.3 10.7 14.9 1.7 18.7 10.3 14.2 1.7 18.3 10.7 72 9 88 165 2.3 0 2.6 1.6 04/07/2007 18:30:00 13.8 2 19.1 8.8 14 2.2 19.9 8.8 13.3 2.1 19.9 8 69 8 61 165 2.4 0 2.6 1.8 04/07/2007 18:40:00 14.1 2.1 18.7 9.1 14.3 2.1 19.1 9.1 13.7 2.1 18.7 8.8 69 8 74 165 2.4 0.1 2.6 1.8 04/07/2007 18:50:00 14.3 2.3 20.2 8 14.6 2.4 20.2 8.4 13.9 2.2 19.5 9.1 70 8 67 165 2.5 0 2.8 2.1 04/07/2007 19:00:00 14.3 2.1 20.2 8.4 14.6 2.3 21 8.4 13.8 2 17.9 8 70 9 81 165 2.6 0 2.8 2.3 04/07/2007 19:10:00 14 1.9 19.1 9.9 14.2 2 19.5 9.5 13.6 1.9 18.3 8.8 71 8 68 165 2.7 0 2.8 2.6 04/07/2007 19:20:00 13.8 1.8 18.7 9.1 14.1 1.9 18.7 9.5 13.4 1.8 18.3 9.1 68 8 75 165 2.6 0 2.8 2.6 04/07/2007 19:30:00 14.4 1.8 19.5 10.3 14.7 1.9 19.9 9.9 14 1.8 18.7 9.1 67 8 57 165 2.7 0 2.8 2.6 04/07/2007 19:40:00 13.1 1.7 17.9 9.1 13.3 1.7 18.3 9.1 12.5 1.5 17.2 8.8 66 10 81 165 2.7 0 2.8 2.6 04/07/2007 19:50:00 14.4 1.9 20.2 9.9 14.6 2 20.6 9.9 14 1.8 19.9 9.1 66 8 72 165 2.7 0 2.8 2.6 04/07/2007 20:00:00 14.4 2.1 19.5 8.8 14.6 2.2 19.5 8.8 13.9 2.1 20.2 9.5 69 9 71 165 2.6 0 2.8 2.6 04/07/2007 20:10:00 14.4 2 19.5 9.9 14.6 2.1 19.9 9.9 13.7 1.7 19.1 9.9 66 9 77 165 2.6 0 2.8 2.6 04/07/2007 20:20:00 14.3 2.2 20.6 8.8 14.5 2.2 21 9.5 13.9 2.2 21.4 9.1 65 9 79 165 2.5 0 2.8 2.3 04/07/2007 20:30:00 13.8 2 18.7 9.5 13.9 2.1 19.1 9.1 13.6 2 18.7 9.1 64 11 57 165 2.5 0 2.8 2.6 04/07/2007 20:40:00 15.3 2.3 20.6 8 15.5 2.4 21.4 8 14.7 2.3 21.4 8 61 9 63 165 2.5 0 2.8 2.3 04/07/2007 20:50:00 14.1 2.1 19.5 9.9 14.2 2.2 20.2 9.9 13.6 2.2 19.5 9.1 57 9 70 165 2.5 0 2.8 2.3 04/07/2007 21:00:00 12.7 2.1 18.3 7.2 12.8 2.2 18.3 7.2 12.2 1.9 17.6 5.7 57 10 71 165 2.5 0 2.8 2.3 04/07/2007 21:10:00 14.5 2.3 21 8 14.7 2.5 21.4 8 14 2.4 20.6 6.8 61 10 86 165 2.4 0 2.6 2.3 04/07/2007 21:20:00 14.2 2.1 19.5 8.8 14.5 2.3 19.9 8.4 13.8 2 18.7 7.2 65 9 67 165 2.3 0 2.6 2.3 04/07/2007 21:30:00 14.5 2.1 19.5 9.5 14.7 2.2 19.5 9.9 14.1 2.3 19.9 9.1 66 9 78 165 2.1 0.1 2.3 1.8 04/07/2007 21:40:00 13.6 2.8 20.2 7.6 13.8 2.9 20.6 7.2 13.3 2.8 20.2 7.2 65 10 68 165 1.9 0 2.1 1.8 04/07/2007 21:50:00 14.5 1.8 20.2 9.1 14.6 2 20.6 8.4 13.9 1.8 18.3 9.5 62 9 61 165 1.9 0 2.1 1.8 04/07/2007 22:00:00 13.2 1.6 17.2 8 13.2 1.7 17.6 8.4 12.7 1.5 16.4 9.1 61 10 50 165 2 0 2.3 1.6 04/07/2007 22:10:00 11.9 2.3 17.2 5.7 11.9 2.4 17.2 5.3 11.5 2.4 17.2 6.1 58 10 71 165 2 0.1 2.3 1.4 04/07/2007 22:20:00 12.7 2.3 19.1 7.6 12.8 2.4 19.1 7.6 12.2 2.3 17.2 6.1 54 11 50 165 1.9 0 2.3 1.6 04/07/2007 22:30:00 12.4 3.1 20.2 6.5 12.5 3.1 21 6.8 12 2.9 21 6.8 53 11 61 165 1.9 0 2.1 1.6 04/07/2007 22:40:00 12.6 2.1 17.6 7.2 12.6 2.1 17.9 7.6 12.1 2 17.6 6.8 52 11 63 165 1.9 0 1.8 1.6 04/07/2007 22:50:00 12.6 2.3 19.1 7.2 12.7 2.3 19.5 7.6 12.3 2 17.6 8 52 10 67 165 1.9 0 2.1 1.4 04/07/2007 23:00:00 11.4 2.4 17.6 6.8 11.4 2.4 17.6 6.5 11 2.2 18.3 6.1 52 11 49 165 2 0 2.3 1.4 04/07/2007 23:10:00 11.9 2.5 18.3 5.7 11.9 2.5 17.9 5.3 11.3 2.6 18.3 5.3 54 11 59 165 2 0 2.3 1.6 04/07/2007 23:20:00 11.4 2.3 16.8 4.9 11.5 2.3 16.4 4.9 10.9 2.3 16.1 5.7 55 9 68 165 2.1 0 2.3 1.6 04/07/2007 23:30:00 11.5 2 18.3 7.2 11.6 2.1 18.7 7.6 11.1 1.9 17.6 6.5 54 9 58 165 2.2 0 2.3 2.1 04/07/2007 23:40:00 12 2.2 18.7 6.1 12.2 2.2 18.7 6.1 11.7 2.2 18.7 6.1 56 10 63 165 2.3 0 2.6 2.1 04/07/2007 23:50:00 12.3 1.8 17.6 7.6 12.4 2 17.6 7.6 11.9 1.8 16.4 7.6 58 12 70 165 2.3 0 2.6 2.3 04/08/2007 00:00:00 12.4 2 19.1 6.8 12.6 2.1 19.5 7.2 12 2.1 18.3 7.6 59 9 51 165 2.4 0 2.6 2.3 04/08/2007 00:10:00 11.6 2 16.8 6.8 11.5 2.1 17.6 6.5 11.2 1.8 16.1 6.5 57 11 74 165 2.4 0 2.6 2.3 04/08/2007 00:20:00 11.7 2.4 17.6 5.3 11.7 2.5 17.9 5.7 11.1 2.3 17.2 5.3 56 10 51 165 2.4 0 2.6 2.3 04/08/2007 00:30:00 11.3 2.1 16.8 7.2 11.3 2.2 17.2 6.8 10.9 2.2 17.2 6.5 57 10 52 165 2.4 0 2.6 2.3 04/08/2007 00:40:00 12.3 2.3 17.6 6.8 12.5 2.4 17.6 6.5 11.7 2.3 17.9 6.1 59 11 59 165 2.4 0 2.6 2.3 04/08/2007 00:50:00 12.4 2.4 18.7 7.6 12.5 2.5 19.1 7.6 12 2.4 18.3 6.5 58 10 47 165 2.3 0 2.6 2.1 04/08/2007 01:00:00 11.7 1.7 17.2 7.6 11.8 1.8 17.2 7.2 11.2 1.7 15.6 6.8 54 10 58 165 2.1 0 2.3 1.8 04/08/2007 01:10:00 10.3 1.7 14.1 6.1 10.4 1.8 14.9 6.5 10.1 1.7 14.5 6.5 48 11 65 165 2 0 2.3 1.8 04/08/2007 01:20:00 10.4 2 15.6 5.3 10.5 2.1 15.6 4.9 10.1 2 15.3 4.9 46 10 49 165 1.9 0 2.1 1.8 04/08/2007 01:30:00 11.4 2 16.4 6.5 11.5 2 16.4 6.5 10.9 1.9 15.6 6.1 51 9 66 165 1.9 0 2.1 1.8 04/08/2007 01:40:00 10.4 2.1 16.8 6.1 10.6 2.2 17.2 6.1 10.1 2.1 15.3 5.7 45 9 42 165 1.8 0 2.1 1.6 04/08/2007 01:50:00 10.2 1.8 15.3 5.7 10.3 1.9 15.6 5.7 9.7 1.8 14.9 4.9 44 10 50 165 1.7 0 1.8 1.1 04/08/2007 02:00:00 9.5 1.5 14.9 5.7 9.6 1.6 14.9 5.3 9.1 1.5 15.3 5.3 42 11 40 165 1.8 0 1.8 1.4 04/08/2007 02:10:00 10.7 1.8 15.3 6.5 10.8 1.8 15.3 6.1 10.4 1.7 15.3 6.8 42 10 39 165 1.8 0.1 1.8 1.4 04/08/2007 02:20:00 9.7 1.9 14.9 5.7 9.8 1.8 15.3 6.1 9.7 1.7 14.9 6.1 40 10 39 165 1.8 0.1 2.1 1.4 04/08/2007 02:30:00 12 2.2 17.6 6.1 12.1 2.3 17.6 6.1 11.2 2.1 16.1 6.5 45 9 38 165 1.8 0.1 2.1 1.4 04/08/2007 02:40:00 10.2 1.7 15.3 6.5 10.3 1.7 15.3 6.8 9.8 1.7 14.9 6.1 40 10 43 165 1.8 0.1 1.8 1.4 04/08/2007 02:50:00 9.3 1.3 12.2 5.7 9.4 1.3 12.2 5.7 9.1 1.2 12.6 5.7 43 10 37 165 1.8 0.1 1.8 1.4 04/08/2007 03:00:00 10.1 2.2 16.8 4.6 10.1 2.2 16.4 4.9 9.8 2.2 15.6 5.3 40 9 52 165 1.8 0.1 2.3 1.4 04/08/2007 03:10:00 10.8 1.9 14.9 6.8 10.7 1.9 14.9 6.5 10.7 1.8 14.5 6.5 42 10 51 165 1.8 0.1 1.8 1.4 04/08/2007 03:20:00 8.8 1.7 13 3.8 8.8 1.7 13 3.8 8.8 1.6 14.1 4.6 42 10 37 165 1.9 0.1 2.1 1.4 04/08/2007 03:30:00 9.9 2.2 16.4 5.7 10 2.2 17.2 6.1 9.5 2.1 16.4 6.1 47 10 39 165 2 0 2.3 1.4 04/08/2007 03:40:00 9.4 1.9 14.5 5.7 9.4 1.9 14.9 6.1 9 1.9 14.1 4.9 42 9 44 165 2 0 2.3 1.6 04/08/2007 03:50:00 9.4 1.7 14.1 5.7 9.4 1.7 14.1 5.7 9.2 1.5 13 6.5 46 9 49 165 2 0.1 2.3 1.4 04/08/2007 04:00:00 11.3 1.7 16.1 7.2 11.2 1.7 16.1 6.8 10.8 1.7 14.9 6.1 53 11 71 165 2 0 2.3 1.4 04/08/2007 04:10:00 11.1 1.9 17.2 6.8 11 2 17.6 7.2 10.7 1.7 15.3 7.2 47 12 68 165 2 0 2.3 1.8 04/08/2007 04:20:00 10.2 1.9 16.4 6.1 10.3 2 16.4 6.5 9.8 1.8 15.6 6.1 49 11 49 165 1.9 0 2.1 1.8 04/08/2007 04:30:00 10.2 2 14.9 4.9 10.1 2.1 15.3 5.3 9.8 2 15.6 5.3 48 11 41 165 2 0 2.3 1.8 04/08/2007 04:40:00 11.3 2.2 16.8 7.2 11.4 2.4 16.8 6.8 10.9 2.2 16.1 6.5 49 11 66 165 1.8 0 2.1 1.6 04/08/2007 04:50:00 9.6 2.3 17.9 5.7 9.6 2.4 17.9 5.3 9.4 2.4 17.6 5.3 47 11 57 165 1.7 0 1.8 1.6 04/08/2007 05:00:00 9.9 1.7 13.7 5.7 10.1 1.8 14.5 5.7 9.8 1.7 13.7 5.3 51 10 57 165 1.9 0.1 2.1 1.6 04/08/2007 05:10:00 8.8 1.7 14.5 4.6 8.6 1.7 13.7 4.6 8.5 1.7 13 4.2 43 11 54 165 2 0 2.3 1.8 04/08/2007 05:20:00 10.1 1.5 14.9 5.7 9.9 1.5 15.6 6.1 9.8 1.4 15.3 6.1 48 11 56 165 2.1 0 2.3 1.8 04/08/2007 05:30:00 9.8 1.9 15.6 5.3 10.1 2 16.1 4.9 9.5 1.9 16.1 5.3 48 12 74 165 2.3 0 2.6 2.1 04/08/2007 05:40:00 9.2 1.5 14.5 4.9 9.4 1.6 14.9 4.9 9.1 1.5 13.7 5.3 46 11 52 165 2.3 0 2.6 2.1 04/08/2007 05:50:00 9.1 1.8 14.5 4.9 9.2 1.8 14.9 4.9 9 1.6 13.3 4.9 43 11 63 165 2.4 0 2.6 2.3 04/08/2007 06:00:00 8.5 1.6 13 4.9 8.5 1.6 13.7 5.3 8.4 1.5 12.2 5.3 45 11 54 165 2.5 0 2.8 2.3 04/08/2007 06:10:00 9.2 1.7 16.1 5.3 9.2 1.7 16.8 4.9 9 1.7 15.6 5.3 43 11 79 165 2.6 0 2.8 2.6 04/08/2007 06:20:00 10.8 2.2 16.8 5.7 10.8 2.2 17.2 5.7 10.3 2.1 15.6 5.7 49 11 46 165 2.6 0 2.8 2.3 04/08/2007 06:30:00 9.3 1.9 13.3 5.7 9.3 1.8 13 6.1 8.8 1.8 13.3 5.3 44 10 27 165 2.6 0 2.8 2.3 04/08/2007 06:40:00 8.8 1.7 13.3 4.6 8.9 1.7 13.7 4.9 8.7 1.5 12.6 5.3 40 10 44 165 2.5 0 2.8 2.1 04/08/2007 06:50:00 8.4 1.1 11.1 5.3 8.4 1.1 11.5 5.7 8.3 1.1 11.8 6.1 40 9 45 165 2.6 0 2.8 2.1 04/08/2007 07:00:00 9.1 1.7 13 5.3 9.2 1.7 13 5.3 8.9 1.5 13 5.3 41 9 36 165 2.7 0 2.8 2.3 04/08/2007 07:10:00 8.4 1.5 14.1 5.3 8.5 1.5 14.1 5.7 8.2 1.3 12.2 4.6 44 10 69 165 2.7 0 2.8 2.3 04/08/2007 07:20:00 7.6 1.6 11.1 3.4 7.7 1.6 11.1 3.8 7.3 1.5 11.1 3 49 11 56 165 2.7 0 2.8 2.3 04/08/2007 07:30:00 7.6 1.4 11.8 4.6 7.7 1.4 11.8 4.9 7.5 1.5 12.2 4.2 45 11 41 165 2.8 0 2.8 2.3 04/08/2007 07:40:00 8.4 1.9 12.2 4.2 8.5 1.9 12.2 4.6 8.1 1.7 12.6 4.2 45 11 23 165 2.7 0 3 2.6 04/08/2007 07:50:00 7.6 1.8 13.3 4.2 7.8 1.8 13.7 4.6 7.4 1.5 11.8 4.6 46 10 60 165 2.7 0 2.8 2.3 04/08/2007 08:00:00 7.9 1.7 11.8 3 8 1.6 12.2 3.8 7.6 1.5 12.2 3.8 43 10 19 165 2.8 0 3 2.6 04/08/2007 08:10:00 9.5 2.1 16.4 4.6 9.6 2.1 16.8 4.6 9.2 1.9 15.3 4.6 56 12 59 165 2.9 0.1 3.3 2.3 04/08/2007 08:20:00 9.5 1.9 14.1 4.9 9.6 2 14.5 5.3 9.4 1.7 14.1 6.1 58 11 61 165 2.9 0.2 3.3 2.3 04/08/2007 08:30:00 7.7 1.9 13.7 4.6 7.8 1.9 13.7 4.2 7.4 1.8 12.6 4.6 45 12 65 165 3 0.1 3.3 2.3 04/08/2007 08:40:00 7.6 1.6 12.2 4.2 7.8 1.6 12.6 4.6 7.3 1.3 12.2 4.6 50 13 63 165 3 0 3.3 2.3 04/08/2007 08:50:00 7.1 1.7 11.5 3.8 7.3 1.7 11.8 3.8 6.9 1.6 11.1 3 52 13 73 165 3 0.1 3.3 2.3 04/08/2007 09:00:00 7.2 1.5 11.1 3.8 7.4 1.4 11.5 3.8 7.1 1.2 10.3 4.2 55 12 62 165 3 0.2 3.3 2.3 04/08/2007 09:10:00 6.2 1.5 10.7 3 6.4 1.5 11.1 3.8 6 1.3 9.5 2.6 55 11 71 165 3 0.2 3.3 2.3 04/08/2007 09:20:00 7.6 1.3 11.1 3.8 7.9 1.4 11.8 4.2 7.3 1.5 11.5 4.2 59 11 77 165 3 0.1 3.3 2.3 04/08/2007 09:30:00 5.9 1.2 9.5 3 6.1 1.2 9.5 3 5.7 1 8.4 3 48 10 65 165 3 0.2 3.3 2.3 04/08/2007 09:40:00 6.7 1.1 9.5 3.8 6.9 1.1 9.9 3.8 6.5 1 9.5 4.2 53 9 46 165 3 0.1 3.3 2.6 04/08/2007 09:50:00 6.4 1.5 11.1 3.8 6.6 1.6 11.5 3.4 6.3 1.5 11.1 3.4 55 9 61 165 3 0.1 3.3 2.6 04/08/2007 10:00:00 7.1 1.5 11.1 4.2 7.3 1.5 11.5 4.6 6.9 1.4 11.5 3.4 57 11 72 165 3.2 0 3.5 2.6 04/08/2007 10:10:00 6.3 1.7 11.1 3.4 6.5 1.7 11.1 3.4 6.2 1.8 11.1 3.4 57 11 51 165 3.2 0 3.5 2.8 04/08/2007 10:20:00 6.5 1.2 9.9 3.4 6.7 1.2 10.3 3.8 6.3 1.2 9.1 3.8 59 12 55 165 3.2 0 3.5 2.8 04/08/2007 10:30:00 5.2 1.6 9.1 2.3 5.5 1.6 9.5 2.6 5.1 1.5 9.1 2.3 55 10 68 165 3.2 0 3.5 3 04/08/2007 10:40:00 5.2 1.2 9.5 2.6 5.5 1.2 9.9 2.6 5 1 8 3 59 10 78 165 3.3 0 3.5 2.8 04/08/2007 10:50:00 5.2 1.5 9.5 2.6 5.5 1.5 9.5 2.6 5.2 1.3 9.1 2.6 55 12 62 165 3.3 0 3.5 3 04/08/2007 11:00:00 5.2 1.1 8.4 2.6 5.4 1.1 8.4 3 5.2 1 8 3 51 13 46 165 3.2 0 3.5 2.8 04/08/2007 11:10:00 5.7 1.1 9.1 3 6 1.1 9.1 3.4 5.6 1 9.1 3.4 54 13 59 165 3.3 0 3.5 2.8 04/08/2007 11:20:00 6 1.5 9.9 3 6.3 1.6 9.9 3 6.1 1.5 9.5 3 58 11 68 165 3.4 0 3.8 3 04/08/2007 11:30:00 7.5 1.3 10.3 3 7.8 1.3 10.3 3.4 7.4 1.3 10.7 3.8 64 10 53 165 3.5 0 3.5 3.3 04/08/2007 11:40:00 7.8 1.3 11.8 4.9 8.1 1.3 11.8 4.9 7.6 1.2 11.1 5.3 67 10 54 165 3.5 0 3.5 3.3 04/08/2007 11:50:00 8 1.5 12.2 4.2 8.2 1.5 12.6 4.2 7.9 1.4 11.5 4.2 67 9 66 165 3.3 0 3.5 3 04/08/2007 12:00:00 7.3 1.4 11.1 3.4 7.5 1.5 11.5 3.8 7.1 1.3 10.7 4.2 63 10 67 165 3.3 0 3.5 3 04/08/2007 12:10:00 8.2 1.4 11.8 3.8 8.4 1.4 12.2 3.8 8.1 1.5 11.8 4.2 66 11 68 165 3.2 0 3.5 2.8 04/08/2007 12:20:00 9.1 1.4 13 5.7 9.3 1.4 13 5.7 9 1.3 11.8 6.5 72 9 63 165 2.9 0.2 3.3 1.8 04/08/2007 12:30:00 9 1 12.2 7.2 9.3 1 12.6 6.8 8.9 1 12.2 6.8 75 8 73 165 2.6 0.1 2.8 2.3 04/08/2007 12:40:00 9.2 1.3 12.2 5.7 9.5 1.3 13 6.1 9.1 1.2 12.2 5.3 72 9 75 165 2.4 0.1 2.8 2.1 04/08/2007 12:50:00 7.4 1.2 9.9 4.6 7.7 1.2 9.9 4.9 7.5 1.1 9.9 4.9 69 9 80 165 2.6 0 2.8 2.3 04/08/2007 13:00:00 8.4 1.3 12.6 4.6 8.7 1.2 13 5.3 8.2 1.2 11.1 4.9 72 10 74 165 2.8 0 3 2.3 04/08/2007 13:10:00 8.9 1.2 11.8 5.7 9.2 1.2 12.2 5.7 8.8 1 11.5 6.1 76 9 78 165 2.8 0.1 3 2.3 04/08/2007 13:20:00 8.4 1.5 11.1 4.6 8.7 1.6 11.5 4.6 8.2 1.4 11.5 4.2 77 10 83 165 2.7 0 3 2.3 04/08/2007 13:30:00 7.4 1.6 11.8 4.9 7.7 1.5 12.2 4.9 7.3 1.5 11.8 4.2 73 9 74 165 3.1 0 3.3 2.6 04/08/2007 13:40:00 7.4 1.3 10.7 4.6 7.8 1.3 11.1 4.6 7.5 1.2 11.1 4.6 72 8 74 165 3.2 0 3.3 2.8 04/08/2007 13:50:00 5.9 1.1 8.4 2.6 6.2 1.1 8.8 3 5.9 1.1 9.1 4.2 64 13 78 165 3.2 0 3.5 2.8 04/08/2007 14:00:00 6.1 1.3 9.9 3.4 6.4 1.3 10.3 3.8 6 1.1 9.1 3.8 62 10 68 165 3.2 0.1 3.5 2.8 04/08/2007 14:10:00 6.9 1.4 10.3 3.8 7.1 1.3 10.7 4.2 7 1.2 10.7 4.6 64 9 49 165 3.1 0.1 3.3 2.6 04/08/2007 14:20:00 7 1.1 9.9 4.6 7.2 1.1 10.3 4.6 7 1 9.5 4.2 64 9 54 165 3 0 3.3 2.6 04/08/2007 14:30:00 6.2 1.5 9.1 3 6.4 1.5 9.1 3 6.1 1.4 9.1 3 58 12 65 165 3 0 3.3 2.6 04/08/2007 14:40:00 4.8 0.8 8 2.6 5 0.8 8 3 4.8 0.7 7.2 3 50 10 59 165 3 0.1 3.3 2.6 04/08/2007 14:50:00 5.1 1.1 8.8 2.6 5.4 1.2 9.1 2.6 5.1 1.1 7.6 2.6 51 12 66 165 3 0.1 3.3 2.6 04/08/2007 15:00:00 6.6 1.2 9.5 4.2 6.8 1.2 9.9 4.2 6.6 1.1 9.5 4.6 60 11 78 165 2.7 0.1 3.3 2.1 04/08/2007 15:10:00 7.1 1.1 9.5 4.2 7.2 1.1 9.9 4.6 7 1 9.1 4.6 62 7 65 165 2.4 0 2.8 1.8 04/08/2007 15:20:00 5.9 1 8.4 3.8 6.1 1 8.4 3.4 6 1 8.4 3.8 58 8 63 165 2.1 0 2.6 1.8 04/08/2007 15:30:00 5.5 1 8.4 3 5.7 1.1 8.4 3.4 5.5 1 8 3.4 50 14 61 165 2 0.1 2.3 1.4 04/08/2007 15:40:00 4.9 1 8 2.3 5.1 1.2 8 2.3 5.2 1 8.4 3 28 10 49 165 1.8 0.1 2.1 1.4 04/08/2007 15:50:00 4.9 0.5 6.8 3.4 5 0.7 7.2 2.3 5.3 0.6 7.2 3.8 23 6 34 165 1.9 0.1 2.1 1.6 04/08/2007 16:00:00 4.6 1.1 8 2.3 4.6 1 6.8 2.3 4.8 1 8 2.3 22 5 11 165 2 0 2.3 1.6 04/08/2007 16:10:00 6.3 1.2 8.8 3.8 6.1 1.3 9.5 3 6.6 1 9.1 4.2 24 10 33 165 2.2 0 2.3 1.8 04/08/2007 16:20:00 6 0.9 8.4 3.4 6.3 0.8 8.4 3.8 6.2 0.9 8 3.8 47 10 63 165 2 0.1 2.3 1.4 04/08/2007 16:30:00 5.2 1 7.2 3 5.5 1.1 7.6 2.3 5.5 1.1 7.6 3 41 10 37 165 1.9 0 2.1 1.6 04/08/2007 16:40:00 4.3 1 6.5 2.3 4.6 0.9 6.8 2.6 4.8 1 7.6 3 28 11 16 165 2.1 0 2.3 1.8 04/08/2007 16:50:00 4 0.8 6.1 1.9 4.3 0.7 5.7 2.3 4.4 0.6 5.7 3 28 9 16 165 2.3 0 2.6 2.1 04/08/2007 17:00:00 4.8 0.7 6.5 2.6 4 1 6.1 1.5 5 0.7 7.2 3.4 12 7 19 165 2.4 0.1 2.6 1.8 04/08/2007 17:10:00 5.7 1.1 8.8 3 4.8 1.2 7.6 1.9 5.6 1.1 8 3.4 14 9 22 165 2.5 0.1 2.8 1.8 04/08/2007 17:20:00 4.7 1.2 8 2.6 4.6 1.1 7.6 2.6 4.7 1.2 7.6 2.6 30 10 11 165 2.6 0.1 2.8 2.1 04/08/2007 17:30:00 3.6 0.8 5.7 2.3 3.6 0.8 5.7 2.3 3.7 0.8 6.8 2.3 36 10 23 165 2.6 0 2.8 2.1 04/08/2007 17:40:00 3.6 0.6 4.9 1.9 3.7 0.6 5.3 1.9 3.7 0.8 5.3 1.9 37 6 34 165 2.6 0.1 2.8 2.1 04/08/2007 17:50:00 3 0.4 4.6 2.3 3.1 0.4 4.9 1.9 3.4 0.4 4.6 2.3 40 5 52 165 2.6 0.1 2.8 2.1 04/08/2007 18:00:00 2.6 0.6 4.2 1.1 2.7 1 4.9 0.7 2.9 0.7 4.6 1.5 66 18 73 165 2.5 0.1 2.8 2.1 04/08/2007 18:10:00 3.4 0.4 4.6 2.6 3.9 0.4 4.9 2.6 3.7 0.4 4.9 3 87 6 83 165 2.5 0.1 2.8 1.8 04/08/2007 18:20:00 2.5 0.5 3.4 1.1 2.6 0.5 3.8 1.5 2.4 0.6 3.8 1.1 98 5 94 165 2.5 0.1 2.8 2.1 04/08/2007 18:30:00 2.8 0.5 4.2 1.9 3 0.5 4.6 1.9 2.6 0.7 4.2 0.7 110 5 106 165 2.8 0.1 3 2.1 04/08/2007 18:40:00 3.6 0.5 4.6 2.6 3.8 0.5 4.9 2.6 3.5 0.4 4.6 2.3 112 4 111 165 2.9 0.1 3.3 2.6 04/08/2007 18:50:00 4.2 0.5 5.7 3.4 4.4 0.5 6.1 3.4 4 0.4 5.3 3 115 3 115 165 2.8 0 3 2.3 04/08/2007 19:00:00 3.8 0.5 4.9 2.3 3.9 0.5 5.3 2.3 3.6 0.4 4.9 2.3 112 7 106 165 2.7 0 2.8 2.3 04/08/2007 19:10:00 4.2 0.4 4.9 3 4.4 0.4 5.3 3 4.1 0.4 4.9 3 110 6 106 165 2.7 0 2.8 2.3 04/08/2007 19:20:00 4.3 0.6 5.7 2.6 4.5 0.6 5.7 2.6 4.3 0.6 5.3 2.6 104 4 107 165 2.7 0 2.8 2.1 04/08/2007 19:30:00 4.2 0.5 5.3 3 4.3 0.5 5.7 3.4 4.3 0.4 5.3 3.4 110 3 114 165 2.7 0 2.8 2.3 04/08/2007 19:40:00 3.7 0.6 4.9 2.6 3.8 0.6 5.3 2.6 3.8 0.6 5.3 2.3 102 8 91 165 2.7 0 2.8 2.3 04/08/2007 19:50:00 3.4 0.5 4.6 2.6 3.6 0.5 4.9 2.6 3.7 0.5 4.9 2.6 96 4 97 165 2.5 0.1 2.8 2.1 04/08/2007 20:00:00 2.7 0.4 3.8 1.9 2.7 0.4 3.8 1.9 3 0.3 3.8 2.3 73 16 57 165 2.4 0.1 2.6 1.8 04/08/2007 20:10:00 2.6 0.5 3.8 1.5 2.5 0.5 3.4 1.5 2.7 0.4 3.8 1.9 41 4 32 165 2.4 0.1 2.8 1.8 04/08/2007 20:20:00 3.3 0.5 4.2 1.5 3.2 0.6 4.6 1.1 3.3 0.5 4.6 1.1 47 13 39 165 2.4 0.1 2.8 2.1 04/08/2007 20:30:00 4.2 0.5 5.3 2.6 4.4 0.6 5.7 2.6 4.4 0.5 5.7 3 72 7 68 165 2.4 0.1 2.8 2.1 04/08/2007 20:40:00 4.7 0.7 6.1 3.4 5.1 0.7 6.5 3.4 4.9 0.6 6.1 3.4 77 6 79 165 2.5 0.1 2.8 2.1 04/08/2007 20:50:00 5.4 0.3 6.5 4.2 5.9 0.4 6.8 4.6 5.6 0.4 6.5 4.2 87 4 84 165 2.6 0.1 2.8 2.3 04/08/2007 21:00:00 5.3 0.4 6.1 3.8 5.7 0.4 6.8 4.2 5.4 0.5 6.5 3.8 96 5 90 165 2.6 0 2.8 2.1 04/08/2007 21:10:00 5.2 0.4 6.1 3.8 5.7 0.4 6.8 4.2 5.4 0.5 6.5 3.8 103 4 95 165 2.7 0 2.8 2.3 04/08/2007 21:20:00 5.3 0.4 6.5 4.2 5.7 0.4 6.8 4.6 5.4 0.5 6.5 3.8 101 3 99 165 2.6 0 2.8 2.3 04/08/2007 21:30:00 5.4 0.6 6.8 3.4 5.9 0.6 7.6 4.2 5.3 0.6 6.8 3.8 104 5 102 165 2.5 0.1 2.8 2.1 04/08/2007 21:40:00 6.8 0.5 8 4.9 7.2 0.5 8.4 5.3 6.8 0.7 8.4 4.6 99 3 99 165 2.4 0.1 2.6 1.8 04/08/2007 21:50:00 6.8 0.4 8 5.3 7.2 0.4 8.4 5.7 6.7 0.6 8 4.6 106 4 103 165 2.3 0.1 2.6 1.8 04/08/2007 22:00:00 6.3 0.7 8 3.8 6.7 0.6 8.4 4.6 6.1 0.7 8 4.2 107 5 100 165 2.4 0.1 2.8 1.8 04/08/2007 22:10:00 5.9 0.6 8 4.2 6.4 0.6 8 4.6 6.1 0.7 8 3.8 103 8 109 165 2.4 0.1 2.6 2.1 04/08/2007 22:20:00 5.8 0.6 7.2 3.8 6.2 0.6 8 4.2 5.6 0.6 7.2 3.8 95 5 94 165 2.4 0 2.6 1.8 04/08/2007 22:30:00 6.6 0.5 7.6 4.6 7 0.5 8 4.9 6.5 0.6 7.6 4.9 93 4 92 165 2.4 0 2.6 2.1 04/08/2007 22:40:00 6.2 0.6 7.2 4.9 6.7 0.6 8 5.3 6.3 0.6 8 4.6 87 6 84 165 2.3 0 2.6 2.1 04/08/2007 22:50:00 6.3 0.5 8 4.9 6.8 0.5 8 5.3 6.4 0.6 8 4.9 86 5 84 165 2.3 0 2.6 2.1 04/08/2007 23:00:00 6 0.6 7.6 4.6 6.4 0.7 8 4.6 6.1 0.6 7.6 4.6 82 4 84 165 2.3 0 2.6 1.8 04/08/2007 23:10:00 5.6 0.4 6.5 3.8 6 0.5 7.2 4.6 5.8 0.5 7.2 4.6 79 4 78 165 2.3 0 2.6 2.1 04/08/2007 23:20:00 4.9 0.5 6.5 3.8 5.4 0.5 6.8 4.2 5.2 0.5 6.8 3.8 79 6 84 165 2.3 0 2.6 2.1 04/08/2007 23:30:00 4.4 0.6 5.7 3 4.7 0.7 6.1 2.6 4.6 0.6 5.7 2.3 74 6 78 165 2.4 0 2.6 1.8 04/08/2007 23:40:00 3.7 0.6 5.3 2.3 3.8 0.7 5.7 2.3 3.7 0.6 5.7 2.3 65 8 66 165 2.3 0 2.6 1.8 04/08/2007 23:50:00 4.1 0.6 5.3 2.6 4.3 0.6 6.1 3 4.2 0.6 5.7 2.3 63 7 71 165 2.3 0 2.6 1.8 04/09/2007 00:00:00 3 0.5 4.6 1.5 2.9 0.6 4.9 1.5 3.1 0.5 4.9 1.9 40 11 52 165 2.3 0 2.8 1.8 04/09/2007 00:10:00 2.4 0.4 3.8 1.5 2.1 0.4 3.8 1.1 2.5 0.4 3.4 1.5 33 8 57 165 2.3 0 2.6 1.8 04/09/2007 00:20:00 2.8 0.5 3.8 1.5 2.5 0.5 3.4 1.1 2.9 0.5 4.2 1.9 30 7 25 165 2.3 0 2.6 2.1 04/09/2007 00:30:00 2.7 0.4 3.8 1.9 2.4 0.4 3.8 1.5 2.9 0.4 3.8 1.9 27 6 33 165 2.3 0 2.6 1.8 04/09/2007 00:40:00 2.2 0.3 3 1.5 2 0.3 2.6 1.5 2.6 0.2 3.4 1.9 21 5 25 165 2.1 0 2.3 1.8 04/09/2007 00:50:00 2 0.4 3 1.1 1.7 0.3 2.6 1.1 2.2 0.4 3 1.5 16 4 12 165 2.1 0 2.3 1.8 04/09/2007 01:00:00 1.1 0.4 1.9 0.4 1 0.3 1.9 0.4 1.5 0.3 2.3 0.7 15 0 15 165 2.2 0 2.3 1.8 04/09/2007 01:10:00 0.6 0.2 1.1 0.4 0.4 0.2 1.1 0.4 1.1 0.3 1.5 0.4 8 5 15 165 2.2 0 2.6 1.8 04/09/2007 01:20:00 0.4 0.1 0.7 0.4 0.4 0.1 0.7 0.4 0.4 0.2 1.1 0.4 358 0 359 165 2.3 0 2.6 1.8 04/09/2007 01:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 358 0 165 165 2.3 0 2.6 1.8 04/09/2007 01:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 340 33 165 165 2.3 0 2.6 1.8 04/09/2007 01:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 267 15 165 165 2.5 0 2.8 2.3 04/09/2007 02:00:00 0.4 0 0.4 0.4 0.4 0.1 0.7 0.4 0.8 0.3 1.1 0.4 227 4 165 165 2.5 0.1 2.8 2.3 04/09/2007 02:10:00 0.4 0 0.4 0.4 0.4 0.1 0.7 0.4 0.4 0.2 1.1 0.4 209 6 165 165 2.3 0 2.6 1.8 04/09/2007 02:20:00 0.9 0.5 1.9 0.4 1 0.5 2.3 0.4 1.2 0.7 2.6 0.4 214 10 211 165 2.2 0.1 2.6 1.8 04/09/2007 02:30:00 2.2 0.3 3 1.1 2.1 0.3 3 1.1 2.6 0.3 3.4 1.9 197 7 194 165 2.3 0.1 2.6 1.8 04/09/2007 02:40:00 2.1 0.5 3.4 1.1 2 0.5 3.4 1.1 2.4 0.4 3.4 1.9 198 5 189 165 2.2 0 2.6 1.8 04/09/2007 02:50:00 2.9 0.3 3.8 2.3 2.7 0.3 3.4 1.9 3 0.3 3.8 2.3 184 2 184 165 2.3 0.1 2.6 1.8 04/09/2007 03:00:00 3.5 0.4 4.6 3 3.3 0.4 4.2 2.6 3.5 0.3 4.6 3 183 3 189 165 2.3 0 2.6 1.8 04/09/2007 03:10:00 4.1 0.2 4.6 3.4 3.8 0.3 4.2 3 4.3 0.3 4.9 3.4 181 3 186 165 2.3 0 2.6 1.8 04/09/2007 03:20:00 3.4 0.3 4.2 3 3.2 0.3 3.8 2.6 3.2 0.4 4.2 2.3 168 12 178 165 2.3 0 2.6 1.8 04/09/2007 03:30:00 4 0.3 4.6 3.4 3.8 0.3 4.2 3 3.9 0.3 4.6 3 145 19 142 165 2 0 2.3 1.8 04/09/2007 03:40:00 3.7 0.4 4.6 3 3.6 0.4 4.6 2.6 3.7 0.4 4.6 3 145 9 158 165 2 0 2.3 1.6 04/09/2007 03:50:00 3.8 0.4 4.6 3 3.5 0.3 4.2 2.6 3.6 0.3 4.2 2.6 146 12 150 165 2 0 2.3 1.6 04/09/2007 04:00:00 4.4 0.3 4.9 3.8 4.1 0.2 4.6 3.4 4.1 0.3 4.9 3.4 149 18 157 165 2.2 0 2.6 1.8 04/09/2007 04:10:00 4.3 0.3 4.9 3.4 3.9 0.3 4.6 3 3.9 0.3 4.6 3 164 21 165 165 2.3 0 2.6 1.8 04/09/2007 04:20:00 3.8 0.4 4.9 2.6 3.7 0.4 4.6 2.6 3.9 0.4 4.9 3 146 9 139 165 2.1 0 2.3 1.6 04/09/2007 04:30:00 4.1 0.4 5.3 3 4.1 0.5 5.3 3 4.5 0.4 6.1 3 144 13 155 165 2.1 0 2.3 1.8 04/09/2007 04:40:00 4.7 0.5 5.7 3.4 4.8 0.5 5.7 3.4 5 0.6 6.5 3.4 151 23 132 165 2 0 2.3 1.8 04/09/2007 04:50:00 3.9 0.5 5.3 2.6 3.9 0.6 5.3 2.6 4.2 0.5 5.7 2.6 154 19 171 165 2 0 2.3 1.8 04/09/2007 05:00:00 4.2 0.7 5.7 3 4 0.6 5.3 2.6 4.1 0.5 5.3 2.6 156 16 171 165 2.1 0 2.3 1.4 04/09/2007 05:10:00 4.3 0.8 6.5 2.6 4.2 0.8 5.7 2.3 4.4 0.8 6.1 3 158 18 152 165 2.1 0 2.3 1.8 04/09/2007 05:20:00 3.9 0.6 5.7 1.9 3.9 0.6 5.7 2.3 4.2 0.6 5.7 3 152 15 165 165 2.1 0 2.6 1.8 04/09/2007 05:30:00 4.1 0.5 5.7 2.6 4.2 0.5 5.3 2.6 4.4 0.5 5.7 3 150 10 153 165 2.1 0 2.3 1.8 04/09/2007 05:40:00 4.5 0.9 6.5 2.6 4.6 0.8 6.8 3 4.7 0.8 6.8 3 154 21 168 165 2.1 0 2.6 1.8 04/09/2007 05:50:00 4.9 0.6 6.5 3.4 5 0.6 6.5 3.4 5.1 0.6 6.8 3.4 155 21 169 165 2.1 0 2.3 1.8 04/09/2007 06:00:00 4.5 0.5 6.1 3.4 4.6 0.5 6.1 3.4 4.8 0.5 6.5 3.8 153 16 148 165 2 0 2.6 1.6 04/09/2007 06:10:00 4.3 0.4 5.3 3 4.5 0.4 5.3 3.4 4.5 0.5 5.3 3.4 151 9 151 165 2 0 2.3 1.6 04/09/2007 06:20:00 4 0.4 5.3 3 4.1 0.4 5.7 3 4.3 0.4 5.3 3.4 148 10 153 165 2 0 2.3 1.8 04/09/2007 06:30:00 5.2 0.7 6.5 3.8 5.4 0.6 6.5 3.8 5.5 0.6 6.8 4.2 150 5 147 165 2.1 0 2.3 1.8 04/09/2007 06:40:00 5.2 0.6 6.8 3.4 5.4 0.5 6.8 3.8 5.4 0.5 6.5 4.2 148 10 149 165 2.1 0 2.3 1.8 04/09/2007 06:50:00 5 0.4 6.1 3.4 5.2 0.4 6.5 3.8 5.3 0.4 6.5 4.2 140 5 128 165 2 0.1 2.3 1.6 04/09/2007 07:00:00 5.2 0.4 6.5 3.8 5.4 0.4 6.8 4.2 5.6 0.4 6.5 4.6 140 5 130 165 1.9 0.1 2.1 1.6 04/09/2007 07:10:00 5.7 0.5 7.2 4.6 5.9 0.5 7.2 4.6 6 0.5 7.2 4.9 136 5 142 165 1.9 0 2.1 1.6 04/09/2007 07:20:00 6 0.5 7.6 4.6 6.2 0.5 7.6 4.6 6.1 0.6 8 4.2 137 6 139 165 1.8 0.1 2.1 1.4 04/09/2007 07:30:00 7 0.5 8.4 5.3 7.1 0.4 8.4 5.7 7.2 0.5 8.4 5.7 134 6 131 165 1.9 0 1.8 1.4 04/09/2007 07:40:00 6.6 0.5 8 5.3 6.7 0.4 8.4 5.7 6.8 0.5 8 5.7 134 5 132 165 1.8 0 1.8 1.4 04/09/2007 07:50:00 5.9 0.5 7.2 4.6 6.1 0.5 7.6 4.6 6.1 0.5 7.6 4.9 131 6 126 165 1.8 0 1.8 1.4 04/09/2007 08:00:00 4.9 0.4 6.1 3.8 5.1 0.4 6.1 3.8 5.1 0.5 6.5 3.8 135 8 122 165 1.9 0.1 2.3 1.4 04/09/2007 08:10:00 4.6 0.4 5.7 3.8 4.7 0.4 5.7 3.8 4.9 0.4 6.5 3.4 144 5 142 165 1.9 0.1 2.1 1.4 04/09/2007 08:20:00 5.1 0.4 6.5 4.2 5.2 0.4 6.5 4.6 5.3 0.4 6.5 4.6 140 5 144 165 1.9 0 2.1 1.6 04/09/2007 08:30:00 5.6 0.4 6.8 4.6 5.8 0.4 6.5 4.6 6 0.5 7.2 4.9 141 4 149 165 1.8 0 1.8 1.6 04/09/2007 08:40:00 6.6 1 9.1 4.6 6.6 0.8 9.1 4.9 6.8 0.8 9.5 4.9 147 7 154 165 1.9 0 2.1 1.6 04/09/2007 08:50:00 8.1 0.8 10.7 6.5 8 0.7 10.3 6.1 8.3 0.7 10.7 6.8 150 11 150 165 2 0.1 2.3 1.4 04/09/2007 09:00:00 8.8 0.6 10.3 7.2 8.5 0.6 9.9 6.8 8.9 0.6 10.7 7.2 151 18 145 165 2.1 0 2.6 1.6 04/09/2007 09:10:00 7.9 0.8 9.9 5.7 7.8 0.7 9.5 5.7 8.2 0.7 9.9 6.5 154 26 143 165 2.1 0 2.3 1.6 04/09/2007 09:20:00 8.7 0.9 10.7 6.5 8.4 0.7 10.3 6.5 8.9 0.8 11.1 6.8 149 15 143 165 2 0.1 2.3 1.6 04/09/2007 09:30:00 7.8 0.7 9.5 4.9 7.6 0.6 9.1 4.9 8 0.6 9.5 6.5 153 24 94 165 2 0 2.3 1.6 04/09/2007 09:40:00 7 0.7 8.4 4.9 6.9 0.6 8.4 5.3 7.3 0.6 8.4 5.7 157 22 170 165 2 0.1 2.3 1.6 04/09/2007 09:50:00 6.1 0.6 7.6 4.6 6.1 0.6 7.6 4.2 6.5 0.6 8.4 4.9 162 16 172 165 2.1 0.2 2.6 1.6 04/09/2007 10:00:00 7.5 0.5 9.1 6.5 7.2 0.5 8.4 6.1 7.8 0.5 9.1 6.8 167 27 165 165 2.1 0.1 2.6 1.6 04/09/2007 10:10:00 8.6 0.6 9.5 6.1 8.2 0.5 9.1 6.5 8.7 0.6 9.9 6.8 161 21 165 165 2.2 0.2 2.6 1.8 04/09/2007 10:20:00 8.2 0.6 9.1 5.7 7.9 0.5 8.8 5.7 8.4 0.5 9.5 6.8 162 17 156 165 2.2 0.2 2.6 1.8 04/09/2007 10:30:00 8.2 0.6 9.5 6.8 7.9 0.5 8.8 6.5 8.5 0.7 9.5 6.8 167 20 175 165 2.5 0.1 2.8 2.1 04/09/2007 10:40:00 8.3 0.7 10.3 6.5 8 0.6 9.9 6.5 8.5 0.7 10.3 6.8 167 22 165 165 2.6 0 2.8 2.3 04/09/2007 10:50:00 9.1 0.6 10.3 7.2 8.7 0.6 9.9 6.8 9.3 0.6 10.7 7.6 169 15 167 165 2.6 0 2.8 2.6 04/09/2007 11:00:00 9 0.4 9.9 7.2 8.6 0.4 9.5 6.8 9.3 0.5 10.3 7.2 170 12 174 165 2.6 0 2.8 2.3 04/09/2007 11:10:00 7.8 0.5 9.1 5.7 7.6 0.5 8.8 5.7 8.1 0.6 9.5 6.1 170 11 169 165 2.7 0 3 2.3 04/09/2007 11:20:00 7.5 0.6 8.8 6.1 7.3 0.5 8.4 6.1 7.9 0.6 9.5 6.5 169 13 172 165 2.7 0 2.8 2.3 04/09/2007 11:30:00 7.8 0.5 9.1 6.1 7.6 0.5 8.4 6.1 8.1 0.5 9.1 6.8 163 17 170 165 2.7 0 3 2.3 04/09/2007 11:40:00 7.7 0.4 8.8 6.5 7.5 0.3 8.4 6.5 8.1 0.4 8.8 6.8 162 19 165 165 3 0.1 3.5 2.3 04/09/2007 11:50:00 8 0.4 8.8 6.8 7.8 0.3 8.4 6.8 8.4 0.4 9.1 7.2 159 17 165 165 3.2 0.1 3.5 2.8 04/09/2007 12:00:00 7.4 0.5 8.4 5.7 7.3 0.4 8.4 5.7 7.8 0.5 9.1 6.5 166 16 150 165 3.5 0.1 3.8 2.8 04/09/2007 12:10:00 7 0.5 8.4 5.7 6.9 0.5 8 5.3 7.5 0.6 8.8 6.1 167 21 165 165 3.3 0 3.5 3 04/09/2007 12:20:00 7.1 0.6 8.8 5.7 7 0.5 8 5.7 7.5 0.5 8.8 6.1 168 11 177 165 3.3 0.1 3.5 3 04/09/2007 12:30:00 7.2 0.4 8.4 6.1 6.9 0.4 8 6.1 7.6 0.4 8.8 6.5 167 17 132 165 3.3 0 3.5 3 04/09/2007 12:40:00 6.7 0.5 7.6 4.9 6.6 0.4 7.6 5.3 7.3 0.4 8.4 6.1 163 22 167 165 3.5 0.1 3.8 3 04/09/2007 12:50:00 7.2 0.4 8 6.1 7.1 0.4 8 6.1 7.8 0.4 9.1 6.1 166 26 171 165 3.9 0 4.3 3.5 04/09/2007 13:00:00 6.7 0.5 7.6 5.3 6.6 0.4 7.6 5.3 7.2 0.5 8.4 6.1 167 22 166 165 3.8 0.1 4.3 3.5 04/09/2007 13:10:00 7.7 0.7 9.1 6.1 7.3 0.6 8.8 5.7 8 0.6 9.5 6.5 169 14 167 165 3.3 0.1 3.5 3 04/09/2007 13:20:00 6.8 0.6 8.4 4.9 6.5 0.5 8 5.3 7.2 0.5 8.4 5.7 172 11 176 165 3.2 0 3.5 2.8 04/09/2007 13:30:00 6.9 0.6 8.4 4.6 6.4 0.6 8 4.2 6.9 0.5 8.8 5.3 175 6 177 165 3.3 0 3.5 3 04/09/2007 13:40:00 6.7 0.5 8 5.3 6.3 0.5 7.2 4.9 6.8 0.5 8 5.3 176 7 177 165 3.3 0 3.8 3.3 04/09/2007 13:50:00 7.1 0.6 8.8 5.7 6.7 0.5 8 5.3 7.3 0.6 9.1 5.7 173 9 179 165 3.3 0 3.5 3 04/09/2007 14:00:00 8.1 0.7 9.1 5.7 7.6 0.6 8.8 5.3 8.2 0.8 9.5 6.1 173 8 176 165 3 0 3.3 2.8 04/09/2007 14:10:00 6.9 0.6 8.4 5.3 6.6 0.5 7.6 5.3 7.1 0.5 8.4 6.1 169 9 165 165 3 0.1 3.3 2.3 04/09/2007 14:20:00 7 0.6 8.4 5.3 6.7 0.6 8 5.3 7.2 0.6 9.1 5.7 174 8 185 165 3.4 0 3.5 3 04/09/2007 14:30:00 7.1 0.6 9.1 5.3 6.7 0.5 8.8 5.3 7.3 0.6 8.8 5.3 174 8 176 165 3.5 0 3.8 3.3 04/09/2007 14:40:00 7.6 0.5 8.8 6.1 7.2 0.5 8 6.1 7.8 0.5 9.1 6.5 169 7 173 165 3.5 0.1 3.8 3.3 04/09/2007 14:50:00 7.8 0.5 9.1 6.1 7.4 0.4 8.4 5.7 8 0.5 9.5 6.5 170 9 166 165 3.5 0 3.8 3.3 04/09/2007 15:00:00 8.4 0.5 9.5 7.2 7.9 0.4 8.8 6.8 8.6 0.5 9.5 6.5 167 17 171 165 3.3 0 3.5 2.8 04/09/2007 15:10:00 8.8 0.5 9.9 7.2 8.2 0.5 9.5 6.8 8.8 0.6 9.9 7.2 166 17 165 165 3 0 3.3 2.3 04/09/2007 15:20:00 8.7 0.7 9.9 6.5 8.3 0.6 9.5 6.1 8.8 0.7 9.9 6.5 170 13 168 165 3 0.1 3.3 2.3 04/09/2007 15:30:00 8.4 0.7 9.9 6.1 8 0.6 9.5 6.5 8.4 0.7 10.3 6.5 173 7 174 165 2.9 0 3.3 2.6 04/09/2007 15:40:00 7.7 0.6 9.1 6.1 7.4 0.5 8.8 5.7 7.7 0.6 8.8 6.5 173 7 171 165 2.9 0 3 2.6 04/09/2007 15:50:00 6.8 0.7 8.8 4.9 6.6 0.6 8.4 5.3 7.1 0.6 8.8 5.3 169 11 166 165 3 0 3.3 2.6 04/09/2007 16:00:00 6.8 0.5 8.4 5.3 6.5 0.4 8 5.3 7.1 0.5 8.4 5.7 168 10 179 165 3 0 3.5 2.8 04/09/2007 16:10:00 6.3 0.5 7.6 4.6 6.1 0.5 7.6 4.9 6.6 0.5 7.6 4.9 170 6 168 165 3 0 3.3 2.8 04/09/2007 16:20:00 6.4 0.6 7.6 4.9 6.1 0.5 7.6 4.9 6.6 0.5 8 4.9 166 13 171 165 3 0.1 3.3 2.6 04/09/2007 16:30:00 6.5 0.6 7.6 4.9 6.1 0.5 7.6 4.6 6.6 0.5 7.6 4.9 167 7 167 165 3 0 3.3 2.8 04/09/2007 16:40:00 6.2 0.6 7.6 4.9 5.9 0.5 7.2 4.6 6.3 0.6 7.6 4.9 169 14 173 165 3 0 3.3 2.8 04/09/2007 16:50:00 6 0.5 7.6 4.6 5.8 0.5 7.2 4.6 6.2 0.6 8 4.6 166 15 169 165 2.8 0.1 3.3 2.1 04/09/2007 17:00:00 6 0.6 8 4.2 5.9 0.6 7.6 4.2 6.3 0.6 7.6 4.6 168 15 173 165 2.7 0.2 3 2.1 04/09/2007 17:10:00 6.5 0.5 7.6 4.9 6.3 0.5 7.6 4.9 6.8 0.6 8.4 5.3 166 15 145 165 2.6 0.1 3 2.1 04/09/2007 17:20:00 6.4 0.5 7.6 4.6 6.1 0.5 7.2 4.6 6.6 0.5 7.6 5.3 170 15 178 165 2.6 0.1 2.8 2.1 04/09/2007 17:30:00 6.7 0.5 8 5.3 6.5 0.4 7.2 5.3 6.9 0.4 8 5.7 170 14 169 165 2.6 0 2.8 2.3 04/09/2007 17:40:00 7.2 0.5 8 5.7 6.9 0.4 8 5.7 7.5 0.5 8.4 6.1 166 17 173 165 2.6 0.1 2.8 1.8 04/09/2007 17:50:00 7.3 0.5 8.4 5.7 7 0.4 8.4 5.7 7.6 0.5 8.8 5.7 166 13 165 165 2.5 0.1 2.8 2.1 04/09/2007 18:00:00 6.6 0.7 8.4 4.9 6.3 0.7 8 4.2 6.8 0.8 8.4 4.9 169 10 158 165 2.6 0 2.8 2.3 04/09/2007 18:10:00 5.8 0.7 7.6 3.4 5.6 0.6 7.2 3.8 6.1 0.7 8 4.2 175 17 191 165 2.7 0.2 3.3 1.8 04/09/2007 18:20:00 6.1 0.9 8 3.8 5.9 0.8 8 3.8 6.3 0.9 8 3.4 183 10 179 165 3.2 0 3.3 2.8 04/09/2007 18:30:00 5.9 0.8 8 3.8 5.7 0.7 7.6 3.8 6.1 0.7 8 4.6 181 8 196 165 2.9 0.1 3.3 2.3 04/09/2007 18:40:00 5.4 0.8 7.2 3.4 5.1 0.8 6.8 3.4 5.5 0.7 7.6 3.4 182 8 189 165 2.7 0 3 2.3 04/09/2007 18:50:00 4.6 0.6 6.5 3 4.4 0.6 6.5 3 4.8 0.5 6.1 3.4 184 11 197 165 2.5 0.1 2.8 2.3 04/09/2007 19:00:00 5.2 0.6 6.8 3.4 5 0.6 6.5 3 5.2 0.7 6.8 3.4 189 7 188 165 2.4 0 2.6 2.3 04/09/2007 19:10:00 5.5 0.9 7.6 3.4 5.3 0.9 7.2 3.4 5.4 0.8 7.2 3.8 186 9 192 165 2.1 0 2.6 1.8 04/09/2007 19:20:00 6.4 0.8 8.8 4.2 6.2 0.8 8 3.8 6.3 0.8 8 4.2 194 5 194 165 2.2 0 2.6 1.6 04/09/2007 19:30:00 5.2 0.6 6.5 3.8 5.2 0.6 6.5 3.8 5.1 0.6 6.5 3.4 195 6 198 165 2.2 0 2.6 1.8 04/09/2007 19:40:00 5.2 0.8 7.2 3.8 5.3 0.8 7.6 3.4 4.9 0.8 6.8 3 198 8 207 165 2.2 0 2.6 2.1 04/09/2007 19:50:00 4.7 0.7 6.5 3 4.8 0.7 6.5 3 4.7 0.8 6.5 3 201 7 212 165 2.3 0 2.6 2.1 04/09/2007 20:00:00 3.8 0.8 6.5 2.3 3.8 0.9 6.5 1.9 3.7 0.9 6.8 1.5 218 10 225 165 2.3 0 2.6 1.8 04/09/2007 20:10:00 4.1 0.7 6.1 2.3 4.1 0.8 6.1 2.3 4 0.8 6.1 1.9 219 7 217 165 2.3 0 2.6 2.1 04/09/2007 20:20:00 3.5 1 5.7 1.9 3.4 1 6.1 1.9 3.4 0.8 5.7 2.3 221 8 218 165 2.3 0 2.6 2.1 04/09/2007 20:30:00 2.2 0.7 3.4 0.4 2.4 0.6 3.8 1.1 2.4 0.4 3.4 1.5 268 23 282 165 2.3 0 2.6 1.8 04/09/2007 20:40:00 2.6 0.3 3.4 1.9 2.6 0.3 3.4 1.9 2.1 0.5 3 1.1 302 5 307 165 2.2 0 2.6 1.8 04/09/2007 20:50:00 2.1 0.8 3.8 0.7 2.1 0.9 3.8 0.4 1.5 0.7 3.4 0.4 294 8 284 165 2 0 2.3 1.8 04/09/2007 21:00:00 0.8 0.4 1.5 0.4 0.6 0.3 1.5 0.4 0.4 0.2 1.5 0.4 284 22 305 165 1.9 0.1 2.6 1.6 04/09/2007 21:10:00 0.8 0.4 1.9 0.4 0.6 0.4 1.5 0.4 0.7 0.4 1.5 0.4 245 9 261 165 2 0 2.3 1.6 04/09/2007 21:20:00 0.7 0.3 1.5 0.4 0.4 0.2 1.1 0.4 0.5 0.3 1.9 0.4 239 4 236 165 2.1 0 2.3 1.8 04/09/2007 21:30:00 0.8 0.4 1.9 0.4 0.6 0.4 1.9 0.4 0.5 0.3 1.5 0.4 274 30 245 165 2 0.1 2.3 1.6 04/09/2007 21:40:00 1.7 0.7 3.4 0.4 1.5 0.8 3.8 0.4 1.2 0.5 2.6 0.4 307 11 294 165 1.8 0 2.1 1.4 04/09/2007 21:50:00 2.3 0.6 3.8 0.7 2.1 0.6 3.8 0.7 1.9 0.6 3.4 0.4 312 10 288 165 1.8 0 1.8 1.4 04/09/2007 22:00:00 2.1 0.5 3.4 1.1 1.9 0.5 3 0.7 1.8 0.5 3 0.7 332 8 341 165 1.5 0 1.8 1.4 04/09/2007 22:10:00 2.1 0.7 3 0.7 2.1 0.6 3.4 0.7 2.3 0.5 3.4 1.1 312 9 310 165 1.6 0 1.8 1.1 04/09/2007 22:20:00 1.3 0.6 2.6 0.4 1.1 0.6 2.6 0.4 1.3 0.6 3 0.4 315 6 306 165 1.7 0 1.8 1.4 04/09/2007 22:30:00 0.5 0.2 1.1 0.4 0.4 0.1 1.1 0.4 0.4 0.1 1.1 0.4 319 4 321 165 1.7 0 1.8 1.1 04/09/2007 22:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 250 47 165 165 1.7 0 1.8 1.4 04/09/2007 22:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 141 1 165 165 1.6 0 1.8 1.4 04/09/2007 23:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 144 0 165 165 1.6 0 1.8 1.4 04/09/2007 23:10:00 0.6 0.3 1.5 0.4 0.6 0.3 1.5 0.4 0.6 0.3 1.1 0.4 147 3 144 165 1.5 0.1 1.8 1.1 04/09/2007 23:20:00 0.8 0.4 1.5 0.4 0.6 0.5 1.9 0.4 0.5 0.4 1.9 0.4 141 7 137 165 1.5 0.1 1.8 1.1 04/09/2007 23:30:00 1.4 0.3 2.3 0.7 1.4 0.4 2.3 0.4 1.4 0.3 2.3 0.7 141 6 149 165 1.5 0.1 1.8 1.1 04/09/2007 23:40:00 1.6 0.3 2.3 0.7 1.6 0.3 2.3 0.7 1.3 0.4 2.3 0.4 145 2 143 165 1.5 0 1.8 1.1 04/09/2007 23:50:00 1.5 0.4 2.3 0.7 1.5 0.5 2.6 0.7 1.1 0.4 1.9 0.4 131 12 119 165 1.4 0.1 1.6 0.9 04/10/2007 00:00:00 1.5 0.4 2.3 0.4 1.5 0.5 2.6 0.4 1.1 0.5 2.3 0.4 124 12 109 165 1.4 0.1 1.8 1.1 04/10/2007 00:10:00 1.2 0.5 2.3 0.4 1.3 0.6 2.6 0.4 0.8 0.5 2.6 0.4 99 11 110 165 1.4 0.1 1.6 0.9 04/10/2007 00:20:00 0.5 0.3 1.5 0.4 0.6 0.4 1.9 0.4 0.5 0.3 1.5 0.4 91 2 91 165 1.4 0.1 1.6 0.9 04/10/2007 00:30:00 0.7 0.4 1.5 0.4 0.7 0.5 1.9 0.4 0.4 0.2 1.5 0.4 102 15 105 165 1.1 0.1 1.6 0.7 04/10/2007 00:40:00 1.8 0.6 2.6 0.4 1.9 0.7 3 0.4 1.4 0.6 2.6 0.4 104 6 97 165 0.9 0 1.4 0.4 04/10/2007 00:50:00 0.9 0.7 2.6 0.4 1 0.8 2.6 0.4 1 0.8 2.6 0.4 113 15 98 165 0.9 0 1.4 0.7 04/10/2007 01:00:00 0.4 0.2 1.1 0.4 0.5 0.3 1.1 0.4 0.4 0.1 1.1 0.4 128 0 128 165 1 0.2 1.4 0.2 04/10/2007 01:10:00 0.4 0.1 1.1 0.4 0.4 0.1 1.1 0.4 0.4 0.1 1.1 0.4 129 0 129 165 0.9 0.1 1.4 0.2 04/10/2007 01:20:00 0.7 0.5 2.6 0.4 0.6 0.4 2.3 0.4 0.4 0.2 1.9 0.4 143 7 150 165 0.8 0 0.9 0.7 04/10/2007 01:30:00 0.4 0.1 1.1 0.4 0.4 0 1.1 0.4 0.4 0.1 1.1 0.4 150 0 150 165 0.6 0.1 0.9 0.2 04/10/2007 01:40:00 0.8 0.4 1.9 0.4 0.6 0.3 1.5 0.4 0.6 0.3 1.9 0.4 152 1 151 165 0.7 0.2 0.9 0.2 04/10/2007 01:50:00 0.5 0.3 1.5 0.4 0.4 0.1 1.1 0.4 0.5 0.3 1.5 0.4 153 0 153 165 0.7 0.2 0.9 0.2 04/10/2007 02:00:00 0.8 0.8 3 0.4 0.7 0.7 3 0.4 0.6 0.4 1.9 0.4 154 3 163 165 0.7 0.2 0.9 0.2 04/10/2007 02:10:00 2.6 0.8 4.6 0.7 2.5 0.9 4.6 0.7 2.4 0.9 4.9 0.7 195 23 190 165 1.1 0.3 1.6 0.7 04/10/2007 02:20:00 2.3 0.7 3.8 0.7 2.1 0.7 3.4 0.4 2.1 0.6 3.8 0.7 179 11 196 165 0.9 0.1 1.4 0.4 04/10/2007 02:30:00 3.3 0.7 5.3 1.5 3.1 0.7 5.3 1.1 3 0.8 4.9 0.7 187 10 192 165 0.8 0 0.9 0.4 04/10/2007 02:40:00 2.7 0.6 3.8 1.1 2.5 0.6 3.8 0.7 2.6 0.5 3.8 1.5 192 8 202 165 0.8 0.1 0.9 0.2 04/10/2007 02:50:00 2.3 0.5 3.4 0.7 2.2 0.5 3.4 0.4 2.3 0.5 3.4 0.7 205 4 198 165 0.8 0.1 0.9 0.2 04/10/2007 03:00:00 2.4 0.3 3 1.9 2.2 0.3 2.6 1.5 2.3 0.3 3 1.9 212 0 211 165 0.7 0.1 0.9 -0.1 04/10/2007 03:10:00 2.7 0.3 3.4 1.9 2.5 0.4 3.4 1.9 2.7 0.3 3.4 1.9 206 7 206 165 0.8 0.1 0.9 0.2 04/10/2007 03:20:00 3 0.3 4.2 2.3 2.9 0.4 3.8 1.9 2.9 0.5 4.2 1.9 206 2 204 165 0.9 0 1.4 0.2 04/10/2007 03:30:00 3.1 0.5 4.6 2.3 3 0.5 4.6 2.3 3 0.5 4.2 1.5 211 2 211 165 1 0 1.4 0.7 04/10/2007 03:40:00 4.4 0.6 5.3 2.6 4.3 0.6 5.3 3 4.2 0.5 5.3 2.6 214 2 210 165 1.2 0.1 1.4 0.9 04/10/2007 03:50:00 4 0.6 5.3 2.3 3.8 0.6 4.9 2.3 3.8 0.6 5.3 2.3 208 9 219 165 1.3 0.1 1.6 0.7 04/10/2007 04:00:00 4.7 0.5 6.1 3.4 4.6 0.5 6.1 3.4 4.5 0.5 5.7 3.4 208 7 205 165 1 0.1 1.4 0.2 04/10/2007 04:10:00 4.8 0.6 6.1 3 4.7 0.6 6.1 2.6 4.5 0.6 6.1 3 213 4 208 165 1.2 0.1 1.6 0.4 04/10/2007 04:20:00 4.1 0.5 5.3 3 3.9 0.5 5.3 2.6 4.1 0.5 5.3 3 194 15 208 165 1.2 0.2 1.6 0.4 04/10/2007 04:30:00 3.6 0.6 4.9 2.3 3.4 0.7 4.9 1.5 3.3 0.6 4.6 1.9 199 11 208 165 0.7 0.1 0.9 0.2 04/10/2007 04:40:00 3.8 0.5 4.9 2.3 3.6 0.5 4.9 1.9 3.4 0.5 4.9 2.3 205 6 207 165 0.6 0 0.9 0.2 04/10/2007 04:50:00 4.7 0.5 5.7 3.4 4.7 0.5 5.7 3 4.6 0.6 5.7 2.6 215 5 214 165 0.8 0.2 1.1 0.2 04/10/2007 05:00:00 4 0.6 5.7 2.3 3.9 0.7 5.3 1.9 3.8 0.6 4.9 2.3 213 6 200 165 0.8 0 0.9 0.7 04/10/2007 05:10:00 4.6 1 6.5 2.6 4.5 1 6.5 2.6 4.4 1 6.8 2.3 212 5 216 165 0.9 0.1 1.4 0.7 04/10/2007 05:20:00 4.4 0.5 5.3 3 4.3 0.5 5.3 2.6 4 0.5 4.9 2.3 208 6 199 165 1.2 0.2 1.6 0.9 04/10/2007 05:30:00 4.5 0.7 6.1 3 4.3 0.7 5.7 2.6 4.4 0.8 6.1 2.6 203 6 194 165 1.2 0.2 1.6 0.7 04/10/2007 05:40:00 3.5 0.6 5.3 2.6 3.3 0.6 5.3 2.3 3.6 0.6 5.7 2.6 165 14 196 165 0.7 0.4 1.4 -0.1 04/10/2007 05:50:00 3.3 0.5 4.6 1.9 3 0.5 4.2 1.9 3.1 0.4 4.2 2.3 178 9 176 165 0.4 0.2 0.9 -0.1 04/10/2007 06:00:00 3.6 0.4 4.6 2.6 3.3 0.4 4.2 2.6 3.3 0.4 4.2 2.3 184 3 180 165 0.8 0.1 1.1 0.4 04/10/2007 06:10:00 3.6 0.6 4.6 2.3 3.3 0.6 4.6 1.9 3.4 0.6 4.6 2.3 181 4 185 165 0.9 0.1 1.1 0.2 04/10/2007 06:20:00 2.7 0.4 3.8 1.9 2.5 0.3 3.4 1.9 2.6 0.3 3.4 1.5 163 9 165 165 0.8 0.2 1.1 0.2 04/10/2007 06:30:00 2.4 0.4 3 0.7 2.2 0.4 3 0.4 2.4 0.4 3 1.1 143 13 145 165 0.6 0 0.9 -0.3 04/10/2007 06:40:00 1.7 0.5 2.6 0.7 1.3 0.5 2.6 0.4 1.5 0.5 2.6 0.4 171 17 168 165 0.7 0.1 0.9 -0.1 04/10/2007 06:50:00 2 0.4 2.6 1.1 1.7 0.4 2.6 0.7 1.7 0.4 2.6 0.7 186 7 186 165 0.8 0 1.1 0.2 04/10/2007 07:00:00 2.5 0.4 3 1.5 2.3 0.4 3 1.1 2.1 0.5 3 0.7 201 5 206 165 1.1 0 1.4 0.9 04/10/2007 07:10:00 2.8 0.3 3.4 1.9 2.6 0.3 3 1.5 2.5 0.4 3 1.5 183 4 181 165 1.1 0 1.4 0.7 04/10/2007 07:20:00 2.7 0.4 3.4 1.9 2.4 0.3 3.4 1.5 2.2 0.4 3 1.1 171 10 179 165 1.1 0 1.4 0.7 04/10/2007 07:30:00 3 0.3 3.4 2.3 2.7 0.3 3 1.9 2.7 0.3 3.4 1.9 157 9 157 165 1 0 1.4 0.7 04/10/2007 07:40:00 3.1 0.3 4.2 2.3 2.7 0.4 3.8 1.9 2.4 0.5 3.8 1.1 178 6 183 165 1.3 0.2 1.8 0.9 04/10/2007 07:50:00 3.2 0.6 4.2 1.5 2.9 0.6 4.2 1.1 2.6 0.7 3.8 0.7 189 7 176 165 1.7 0 1.8 1.1 04/10/2007 08:00:00 2.5 0.5 3.4 1.5 2.3 0.5 3.4 0.7 1.9 0.6 3.4 0.4 190 11 197 165 2 0.1 2.6 1.6 04/10/2007 08:10:00 2 0.5 3 0.4 1.7 0.5 3 0.4 1.6 0.5 3 0.4 174 15 171 165 2.4 0.1 2.8 1.8 04/10/2007 08:20:00 2.3 0.4 3.4 1.1 2.1 0.5 3.4 0.7 2.1 0.6 3.4 0.4 179 15 174 165 2.2 0 2.6 1.8 04/10/2007 08:30:00 2.5 0.5 4.2 1.1 2.2 0.5 3.8 0.7 2.5 0.5 3.8 1.1 171 13 162 165 2.6 0 3 1.8 04/10/2007 08:40:00 2.7 1 4.2 0.4 2.4 1 4.2 0.4 2.8 0.8 4.2 0.7 169 13 165 165 3 0 3.3 2.8 04/10/2007 08:50:00 3.9 0.4 4.9 3 3.6 0.4 4.9 2.6 4 0.4 4.9 3 162 12 154 165 2.7 0.2 3.3 2.3 04/10/2007 09:00:00 4 0.4 5.3 3 3.8 0.5 4.9 2.6 4.1 0.4 5.3 2.6 152 10 135 165 2.3 0 2.6 1.8 04/10/2007 09:10:00 3.9 0.3 4.9 2.6 3.6 0.4 4.6 2.3 4 0.3 4.6 3.4 156 9 147 165 2.3 0.1 2.6 2.1 04/10/2007 09:20:00 3.4 0.3 4.2 2.3 3.1 0.4 4.2 2.3 3.5 0.4 4.6 2.6 155 9 162 165 2.7 0 3 2.3 04/10/2007 09:30:00 4.2 0.4 5.3 3 3.8 0.4 4.6 2.6 4.2 0.4 5.7 3 157 12 158 165 2.7 0.1 3 2.3 04/10/2007 09:40:00 4.5 0.4 5.3 3.4 4.3 0.4 5.3 3.4 4.6 0.4 5.7 3.8 156 11 138 165 2.9 0 3.3 2.6 04/10/2007 09:50:00 4.5 0.4 5.7 3.4 4.1 0.5 5.7 3 4.5 0.4 5.7 3.4 158 10 165 165 2.9 0.1 3.5 2.6 04/10/2007 10:00:00 4.2 0.5 5.3 3 3.8 0.5 5.3 2.6 4.1 0.5 5.7 3 157 11 147 165 2.7 0.2 3.3 2.3 04/10/2007 10:10:00 4.3 0.5 6.1 3 4 0.6 5.7 2.6 4.4 0.5 6.1 3 155 13 157 165 2.9 0.2 3.3 2.6 04/10/2007 10:20:00 4.6 0.7 6.5 2.6 4.3 0.7 6.1 2.3 4.7 0.7 6.8 2.6 159 10 171 165 3.3 0.2 3.8 3 04/10/2007 10:30:00 4.5 0.5 6.1 3 4.2 0.5 5.7 3 4.6 0.4 5.7 3.4 165 17 153 165 3.2 0.2 3.5 2.8 04/10/2007 10:40:00 4.3 0.5 5.3 3 4.1 0.6 5.3 2.6 4.5 0.5 6.1 3.4 154 17 153 165 3.2 0 3.5 3 04/10/2007 10:50:00 4.6 0.6 6.1 3 4.5 0.6 6.5 2.6 4.8 0.5 6.1 3.4 157 13 151 165 3.4 0.2 3.8 2.8 04/10/2007 11:00:00 4.8 0.5 6.1 3.4 4.8 0.5 6.5 3.4 5 0.5 6.5 3.8 148 14 134 165 3.7 0.2 4.3 3 04/10/2007 11:10:00 5.9 1 8.4 3.4 5.8 1 8.4 3.8 6.1 1 8.8 3.8 153 12 183 165 3.5 0.2 4 3 04/10/2007 11:20:00 6.1 0.6 8 4.6 6 0.5 7.6 4.6 6.3 0.6 8.4 4.6 151 14 165 165 3.3 0.2 3.8 2.8 04/10/2007 11:30:00 5.3 0.7 6.8 3.4 5.3 0.7 7.2 3.8 5.5 0.7 7.2 3.8 153 15 144 165 3.3 0.5 4.3 2.6 04/10/2007 11:40:00 5.8 0.5 7.2 4.2 5.9 0.5 7.2 4.6 6.1 0.4 7.2 4.9 150 9 150 165 3.6 0.2 4.3 3.3 04/10/2007 11:50:00 5.2 0.6 7.2 3.4 5.3 0.6 7.2 3.4 5.5 0.6 7.2 3.8 151 10 165 165 3.5 0.2 4 3 04/10/2007 12:00:00 5.1 0.8 7.2 3 5.1 0.7 6.8 3.4 5.4 0.8 7.2 3.8 165 14 166 165 3.3 0.2 4 2.8 04/10/2007 12:10:00 4.5 0.6 5.7 2.6 4.6 0.6 6.1 3 4.7 0.7 6.1 3 162 13 139 165 3 0.1 3.3 2.8 04/10/2007 12:20:00 4 0.5 5.7 2.6 4 0.5 5.3 2.6 4.1 0.6 5.7 2.6 161 11 164 165 3 0 3.3 2.8 04/10/2007 12:30:00 4.5 0.5 5.3 3.4 4.5 0.4 5.7 3.4 4.7 0.5 6.1 3.4 164 12 165 165 3.6 0.5 5 3 04/10/2007 12:40:00 4.6 0.7 6.5 3.4 4.8 0.6 6.5 3.8 4.9 0.6 6.8 3.4 153 10 155 165 4.8 0.1 5.5 4.5 04/10/2007 12:50:00 5.3 0.8 7.6 3.4 5.4 0.6 6.8 3.4 5.6 0.7 7.2 4.2 147 8 154 165 4.5 0 4.8 4.3 04/10/2007 13:00:00 5.9 0.5 8 4.9 5.9 0.5 7.2 4.9 6.2 0.5 7.6 4.9 150 5 150 165 4.5 0.1 4.8 4.3 04/10/2007 13:10:00 5.4 0.7 7.6 3.8 5.3 0.7 7.2 3.8 5.5 0.7 7.6 4.2 152 8 151 165 3.7 0.2 4.5 3.5 04/10/2007 13:20:00 5.4 0.9 7.2 3.4 5.4 0.8 6.8 3.8 5.6 0.8 7.6 4.2 152 5 152 165 3.6 0.2 4 3 04/10/2007 13:30:00 6.1 0.6 7.2 4.2 6.1 0.5 7.2 4.6 6.1 0.6 7.2 4.6 137 7 119 165 2.7 0.3 3.3 2.3 04/10/2007 13:40:00 5 0.7 6.5 3 5.2 0.6 6.8 3.4 5.2 0.6 6.8 3.4 135 7 128 165 2.4 0 2.6 2.3 04/10/2007 13:50:00 4.7 0.5 6.5 3.4 5 0.5 6.5 3.8 5 0.5 6.5 3.8 134 7 142 165 2.6 0.1 3 2.3 04/10/2007 14:00:00 4.9 0.5 6.5 3.4 5.2 0.5 6.5 4.2 5.2 0.5 6.5 3.8 138 8 122 165 2.9 0 3 2.6 04/10/2007 14:10:00 4.4 0.5 5.7 3.4 4.7 0.5 6.1 3.4 4.8 0.5 6.5 3.4 139 7 139 165 2.8 0.1 3.3 2.6 04/10/2007 14:20:00 4.6 0.5 6.1 3.4 4.9 0.5 6.1 3.4 4.8 0.5 6.5 3.4 142 7 138 165 2.9 0.3 3.8 2.6 04/10/2007 14:30:00 5.2 0.6 6.8 3.8 5.4 0.5 6.8 4.2 5.6 0.6 7.6 4.2 145 5 145 165 3.6 0.4 4.8 3 04/10/2007 14:40:00 6.1 0.5 7.2 4.6 6.1 0.5 6.8 4.9 6.3 0.5 7.6 4.9 152 5 152 165 3.1 0 3.3 2.8 04/10/2007 14:50:00 5.5 0.5 6.5 3.8 5.6 0.5 6.8 3.8 5.8 0.5 6.8 4.6 152 6 148 165 3.2 0 3.5 3 04/10/2007 15:00:00 4.5 0.6 6.1 2.6 4.7 0.6 6.1 3 4.9 0.7 6.5 3 156 7 151 165 3.4 0 3.5 3.3 04/10/2007 15:10:00 3.6 0.5 4.6 2.6 3.6 0.4 4.6 2.6 3.8 0.5 4.9 2.3 154 13 145 165 3.3 0.1 3.8 3 04/10/2007 15:20:00 3.1 0.6 4.6 1.9 3.3 0.6 4.6 2.3 3.5 0.6 4.9 2.3 141 13 145 165 4 0.4 4.8 3.5 04/10/2007 15:30:00 4.1 0.5 4.9 2.6 4.1 0.4 4.9 2.6 4.2 0.5 4.9 2.3 153 5 159 165 4 0.3 5 3.5 04/10/2007 15:40:00 4.3 0.6 5.7 3 4.1 0.6 5.7 2.6 4.4 0.6 6.1 3 157 13 165 165 3.6 0.1 3.8 3.5 04/10/2007 15:50:00 4.5 0.5 5.7 3 4.6 0.5 5.7 3.4 4.9 0.5 6.1 3.8 154 9 158 165 3.5 0 3.5 3.3 04/10/2007 16:00:00 3.6 0.5 4.9 2.3 3.7 0.6 5.3 2.3 3.8 0.6 5.3 2.6 158 12 145 165 3.5 0.1 3.8 3.3 04/10/2007 16:10:00 3.5 0.9 5.3 1.5 3.6 0.8 5.3 1.1 3.7 1 5.7 2.3 152 13 159 165 4.1 0.3 4.8 3.5 04/10/2007 16:20:00 5.2 0.5 7.2 3.8 5.1 0.5 7.2 3.8 5.3 0.6 6.8 3.8 156 12 163 165 5.1 0.2 5.7 4.5 04/10/2007 16:30:00 4.6 0.5 5.7 3.4 4.5 0.6 6.1 3 4.6 0.5 6.1 3.4 166 13 153 165 5.3 0 5.7 5.2 04/10/2007 16:40:00 4.5 0.4 5.3 3.4 4.2 0.4 5.7 3 4.5 0.4 5.7 3.4 161 11 167 165 5.4 0 5.5 5.2 04/10/2007 16:50:00 4 0.6 5.7 2.6 3.8 0.6 5.3 2.6 3.9 0.6 5.3 1.9 163 12 165 165 5.5 0 5.7 5.2 04/10/2007 17:00:00 4.3 0.6 5.7 2.3 4.3 0.6 5.7 2.3 4.3 0.7 6.5 2.3 196 22 165 165 5.4 0.1 5.7 5 04/10/2007 17:10:00 4.2 0.6 5.7 3 4.3 0.6 5.7 3 4.4 0.6 5.7 3 211 6 210 165 5 0.1 5.7 4.8 04/10/2007 17:20:00 4.4 0.4 5.7 3 4.4 0.5 5.7 3.4 4.6 0.5 6.5 3.4 209 6 217 165 4.8 0.1 5.2 4.5 04/10/2007 17:30:00 3.6 0.5 4.9 2.6 3.7 0.5 4.9 2.6 3.7 0.5 4.9 2.6 206 8 218 165 4.9 0 5 4.8 04/10/2007 17:40:00 3.3 0.6 4.6 1.9 3.3 0.6 4.9 1.9 3.3 0.5 4.6 1.9 197 12 205 165 5 0 5.2 4.8 04/10/2007 17:50:00 3.4 0.5 4.9 1.9 3.3 0.5 4.9 1.9 3.4 0.5 4.9 2.3 181 9 187 165 4.9 0 5 4.8 04/10/2007 18:00:00 3.7 0.5 4.9 2.3 3.7 0.5 4.9 2.3 3.9 0.5 4.9 2.3 184 11 191 165 4.6 0 4.8 4.3 04/10/2007 18:10:00 4.2 0.6 5.7 2.6 4.2 0.6 5.7 2.6 4.3 0.7 5.7 2.3 194 6 192 165 4.4 0 4.8 4.3 04/10/2007 18:20:00 4.4 0.6 5.7 2.6 4.4 0.6 5.7 2.6 4.5 0.7 6.1 2.6 197 5 203 165 4.3 0 4.5 3.8 04/10/2007 18:30:00 3.3 0.5 4.6 2.3 3.4 0.5 4.6 2.3 3.4 0.6 4.6 2.3 205 9 191 165 4.3 0 4.5 4.3 04/10/2007 18:40:00 3.4 0.4 4.9 2.3 3.4 0.4 4.9 2.3 3.4 0.5 4.6 1.9 215 9 216 165 4.3 0.1 4.5 3.8 04/10/2007 18:50:00 3.1 0.6 4.2 1.9 3.2 0.5 4.6 1.9 3 0.4 4.2 1.9 235 10 235 165 4 0 4.3 3.8 04/10/2007 19:00:00 2.3 0.4 3.4 1.5 2.3 0.4 3.4 1.5 2.5 0.4 3.8 1.9 231 7 227 165 3.8 0 4 3.8 04/10/2007 19:10:00 1.9 0.3 2.6 1.1 1.9 0.3 2.6 1.1 2.1 0.4 2.6 1.1 228 5 229 165 3.8 0 4 3.5 04/10/2007 19:20:00 1.5 0.3 2.3 0.7 1.8 0.4 2.6 0.7 1.8 0.3 2.3 1.1 252 8 249 165 3.8 0 4.3 3.5 04/10/2007 19:30:00 1.4 0.3 1.9 0.7 1.6 0.3 2.3 0.7 1.7 0.2 2.3 1.1 246 16 266 165 3.6 0.2 4.3 3 04/10/2007 19:40:00 1.3 0.3 2.3 0.7 1.5 0.4 2.3 0.7 1.5 0.4 2.3 0.7 237 13 238 165 3.2 0.2 3.5 2.6 04/10/2007 19:50:00 2.7 0.6 3.4 1.1 2.9 0.4 3.4 1.5 2.9 0.4 3.4 1.9 242 6 238 165 2.6 0.2 3.3 1.8 04/10/2007 20:00:00 2.6 0.3 3.4 2.3 2.7 0.3 3.4 2.3 2.6 0.3 3.4 2.3 228 3 234 165 2.4 0 2.6 2.3 04/10/2007 20:10:00 2 0.3 2.6 1.5 2.2 0.3 2.6 1.9 2 0.3 2.6 1.5 228 3 225 165 2.5 0 2.8 2.3 04/10/2007 20:20:00 1.3 0.4 2.3 0.4 1.8 0.3 2.3 1.1 1.3 0.4 2.3 0.4 247 12 238 165 2.7 0 2.8 2.3 04/10/2007 20:30:00 1.2 0.3 1.9 0.4 1.6 0.3 2.3 0.7 1 0.4 1.9 0.4 287 5 281 165 2.6 0.1 2.8 2.3 04/10/2007 20:40:00 1.6 0.3 2.3 0.7 2 0.3 2.6 1.1 1.6 0.4 2.6 0.7 288 4 286 165 2.4 0 2.8 2.3 04/10/2007 20:50:00 1.7 0.4 2.6 0.7 2.1 0.3 3 1.5 1.4 0.6 3 0.4 291 6 285 165 2.3 0 2.6 1.8 04/10/2007 21:00:00 2.1 0.7 4.2 0.7 2.4 0.6 4.2 1.1 1.7 0.7 3 0.4 296 8 298 165 2.3 0 2.8 1.8 04/10/2007 21:10:00 2.9 0.3 3.8 2.3 3.1 0.3 3.8 2.6 2.2 0.4 3 1.1 294 4 298 165 2.1 0 2.3 1.6 04/10/2007 21:20:00 2.2 0.5 3.4 0.7 2.5 0.5 3.4 1.1 1.6 0.4 2.6 0.4 292 6 296 165 2.1 0 2.3 1.8 04/10/2007 21:30:00 2 0.4 2.6 0.7 2.3 0.4 3 1.5 1.4 0.4 2.6 0.4 292 6 284 165 2.2 0 2.6 1.8 04/10/2007 21:40:00 1.7 0.4 2.6 0.4 1.8 0.5 2.6 0.4 1.5 0.4 2.3 0.4 323 13 322 165 1.9 0 2.3 1.8 04/10/2007 21:50:00 1.8 0.4 3 0.7 2 0.5 3 0.4 1.8 0.5 3 0.4 319 15 292 165 1.8 0 2.1 1.6 04/10/2007 22:00:00 1.8 0.4 3 0.7 2 0.4 3 1.1 1.9 0.4 3 1.1 305 8 310 165 1.8 0.1 1.8 1.6 04/10/2007 22:10:00 0.6 0.4 1.9 0.4 0.6 0.5 2.3 0.4 0.7 0.4 1.9 0.4 307 20 298 165 1.9 0 2.1 1.6 04/10/2007 22:20:00 0.5 0.2 1.1 0.4 0.5 0.2 1.1 0.4 0.6 0.3 1.5 0.4 270 19 280 165 1.9 0 2.1 1.8 04/10/2007 22:30:00 0.5 0.3 1.1 0.4 0.5 0.3 1.5 0.4 0.5 0.3 1.9 0.4 216 12 239 165 1.8 0 2.1 1.6 04/10/2007 22:40:00 0.4 0.2 1.9 0.4 0.5 0.4 2.3 0.4 0.6 0.6 2.6 0.4 226 22 244 165 1.5 0 1.6 1.4 04/10/2007 22:50:00 0.4 0.1 1.1 0.4 0.4 0.2 1.5 0.4 0.5 0.2 1.5 0.4 250 3 261 165 1.7 0 1.8 1.4 04/10/2007 23:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 247 1 165 165 1.6 0.1 1.8 1.4 04/10/2007 23:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 247 0 165 165 1.1 0.1 1.4 0.9 04/10/2007 23:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.7 0.4 247 0 165 165 1.3 0.1 1.6 0.9 04/10/2007 23:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 247 0 165 165 1.4 0 1.6 1.4 04/10/2007 23:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 276 11 165 165 1 0.2 1.4 0.9 04/10/2007 23:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 280 0 165 165 0.8 0 0.9 0.7 04/11/2007 00:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 280 0 165 165 0.7 0 0.9 0.7 04/11/2007 00:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.7 0.4 288 18 165 165 0.4 0 0.7 0.2 04/11/2007 00:20:00 0.5 0.3 1.1 0.4 0.6 0.3 1.1 0.4 0.7 0.4 1.5 0.4 332 1 333 165 0.4 0 0.7 0.2 04/11/2007 00:30:00 1.1 0.3 1.9 0.4 1.1 0.3 1.9 0.4 1.1 0.2 1.5 0.7 335 3 340 165 0.4 0 0.7 0.2 04/11/2007 00:40:00 2 0.3 2.6 1.1 1.4 0.4 2.3 0.4 2 0.5 2.6 1.1 9 7 12 165 0.3 0 0.7 0.2 04/11/2007 00:50:00 1.9 0.2 2.6 1.5 1.5 0.3 1.9 0.7 2.2 0.2 2.6 1.9 12 0 12 165 0.5 0 0.7 0.2 04/11/2007 01:00:00 2 0.2 2.3 1.5 2.1 0.2 2.3 1.5 2.4 0.2 2.6 1.9 17 4 12 165 0.7 0.1 0.9 0.2 04/11/2007 01:10:00 1.4 0.3 2.3 0.7 1.4 0.4 2.3 0.7 1.9 0.2 2.3 1.5 37 4 27 165 1.1 0.2 1.4 0.7 04/11/2007 01:20:00 1.5 0.2 1.9 1.1 1.6 0.2 1.9 1.1 1.9 0.2 2.3 1.5 49 4 41 165 1.2 0 1.4 0.9 04/11/2007 01:30:00 1.5 0.2 1.9 1.1 1.5 0.2 1.9 1.1 1.7 0.2 2.3 1.1 43 5 52 165 0.9 0.2 1.4 0.4 04/11/2007 01:40:00 1.1 0.3 1.9 0.4 0.9 0.4 1.9 0.4 1.3 0.2 1.9 0.7 33 5 25 165 0.3 0.1 0.7 0.2 04/11/2007 01:50:00 2 0.2 2.3 1.5 1.9 0.2 2.3 1.5 1.8 0.2 2.3 1.1 22 0 23 165 0 0 0.2 -0.3 04/11/2007 02:00:00 2.3 0.2 2.6 1.9 2.2 0.4 3 1.5 1.9 0.3 2.6 1.5 22 5 22 165 -0.1 0 0.2 -0.3 04/11/2007 02:10:00 2.3 0.2 2.6 1.9 2.1 0.3 2.6 1.1 1.9 0.3 2.3 1.5 19 3 16 165 -0.2 0 -0.1 -0.3 04/11/2007 02:20:00 2.2 0.3 2.6 1.5 2.2 0.3 2.6 1.5 2.2 0.2 2.6 1.9 22 0 22 165 -0.2 0 0.2 -0.3 04/11/2007 02:30:00 1.9 0.3 2.6 1.5 1.9 0.3 2.6 1.1 2.2 0.2 2.6 1.9 22 2 25 165 0.1 0 0.2 -0.1 04/11/2007 02:40:00 1.6 0.2 2.3 1.1 1.1 0.5 2.3 0.4 1.7 0.3 2.3 1.1 12 6 20 165 0 0 0.2 -0.1 04/11/2007 02:50:00 1.8 0.2 2.3 1.5 1.8 0.2 2.3 1.5 2.1 0.2 2.3 1.5 25 5 20 165 0 0 0.4 -0.3 04/11/2007 03:00:00 1 0.4 1.9 0.4 0.9 0.5 1.9 0.4 1.5 0.4 2.3 0.7 39 8 32 165 0.7 0.2 1.1 0.2 04/11/2007 03:10:00 0.5 0.3 1.5 0.4 0.7 0.3 1.5 0.4 1.2 0.4 1.9 0.4 95 22 115 165 0.7 0.1 1.1 0.2 04/11/2007 03:20:00 1.2 0.3 1.9 0.4 1.5 0.3 1.9 0.4 1.8 0.2 2.3 1.1 92 3 92 165 0.5 0 0.7 0.2 04/11/2007 03:30:00 1.4 0.3 2.3 0.7 1.7 0.2 2.3 1.1 1.9 0.2 2.3 1.5 84 5 65 165 0.6 0 0.9 0.2 04/11/2007 03:40:00 1.3 0.5 1.9 0.4 1.6 0.5 2.3 0.4 1.8 0.3 2.3 0.7 72 9 82 165 0.5 0 0.9 0.4 04/11/2007 03:50:00 0.8 0.4 1.5 0.4 1.1 0.5 2.3 0.4 1.6 0.4 2.6 0.4 63 14 55 165 0.7 0 0.9 0.7 04/11/2007 04:00:00 1.8 0.3 2.3 1.1 2.2 0.2 2.6 1.5 2.3 0.2 2.6 1.9 90 2 86 165 0.4 0.1 0.9 0.2 04/11/2007 04:10:00 1.7 0.2 2.3 1.1 2.1 0.2 2.3 1.5 2 0.2 2.3 1.9 90 1 91 165 0.2 0 0.7 -0.1 04/11/2007 04:20:00 1.3 0.4 1.9 0.4 1.8 0.4 2.6 0.4 2 0.3 2.6 1.5 81 8 88 165 0.2 0 0.7 -0.1 04/11/2007 04:30:00 0.6 0.3 1.5 0.4 0.6 0.3 1.5 0.4 1.4 0.3 1.9 0.4 65 8 71 165 0.5 0 0.9 0.2 04/11/2007 04:40:00 0.7 0.4 1.5 0.4 0.7 0.4 1.5 0.4 1.3 0.3 1.9 0.4 45 12 54 165 0.2 0.1 0.7 -0.1 04/11/2007 04:50:00 1.1 0.4 1.9 0.4 1 0.4 1.9 0.4 1.2 0.3 1.9 0.4 28 6 18 165 -0.1 0 -0.1 -0.3 04/11/2007 05:00:00 0.6 0.3 1.9 0.4 0.5 0.3 1.9 0.4 0.9 0.3 1.5 0.4 33 10 52 165 -0.1 0 0.2 -0.3 04/11/2007 05:10:00 0.6 0.3 1.5 0.4 0.7 0.4 1.9 0.4 1 0.4 1.9 0.4 38 9 29 165 -0.2 0.1 -0.1 -0.3 04/11/2007 05:20:00 0.4 0 0.4 0.4 0.4 0.1 0.7 0.4 0.7 0.3 1.5 0.4 54 8 165 165 -0.3 0 -0.1 -0.5 04/11/2007 05:30:00 0.9 0.6 2.3 0.4 0.8 0.6 2.3 0.4 1.3 0.5 2.3 0.4 28 9 20 165 -0.2 0 -0.1 -0.3 04/11/2007 05:40:00 1.8 0.3 2.6 1.1 1.3 0.5 2.6 0.4 2.3 0.2 3 1.9 13 6 23 165 -0.2 0 -0.1 -0.3 04/11/2007 05:50:00 2 0.2 2.3 1.5 1.2 0.4 2.3 0.4 2.4 0.2 2.6 1.9 9 4 6 165 -0.2 0 -0.1 -0.3 04/11/2007 06:00:00 1.4 0.4 2.3 0.7 1.3 0.3 2.3 0.7 1.8 0.3 2.6 1.1 26 9 13 165 -0.1 0.1 0.2 -0.3 04/11/2007 06:10:00 1.2 0.2 1.9 0.7 1.1 0.2 1.9 0.7 1.7 0.2 2.3 1.5 35 0 35 165 0.2 0 0.7 -0.1 04/11/2007 06:20:00 1.9 0.3 2.6 1.1 1.8 0.3 2.6 1.1 2.2 0.3 3 1.5 31 4 19 165 0 0.1 0.2 -0.3 04/11/2007 06:30:00 2.2 0.2 2.6 1.5 2.2 0.2 2.6 1.5 2.4 0.3 3 1.5 26 2 27 165 0.3 0.1 0.7 0.2 04/11/2007 06:40:00 1.9 0.3 2.6 1.5 2 0.2 2.6 1.5 2.1 0.2 2.6 1.5 43 9 32 165 0.2 0 0.7 -0.1 04/11/2007 06:50:00 2 0.2 2.6 1.5 2.1 0.2 2.6 1.5 2.2 0.2 2.6 1.5 40 7 35 165 0.5 0 0.9 0.2 04/11/2007 07:00:00 2.3 0.4 3 1.5 2.3 0.3 3 1.5 2.5 0.4 3.4 1.9 26 6 26 165 1 0.2 1.6 0.7 04/11/2007 07:10:00 2.5 0.3 3 1.9 2.5 0.3 3.4 1.9 2.6 0.3 3.4 1.9 23 5 18 165 1.3 0 1.6 1.1 04/11/2007 07:20:00 2.2 0.4 3 1.1 2.3 0.4 3 1.5 2.4 0.4 3.4 1.1 29 4 27 165 1.2 0.1 1.6 0.9 04/11/2007 07:30:00 2.3 0.4 3 1.1 2.3 0.3 3 1.5 2.6 0.3 3.4 1.5 30 6 37 165 1.3 0.1 1.6 1.1 04/11/2007 07:40:00 2.3 0.2 3 1.9 2.3 0.3 3 1.5 2.6 0.3 3.4 1.5 27 5 31 165 1.4 0.1 1.8 0.7 04/11/2007 07:50:00 2.5 0.4 3.4 1.5 2.5 0.4 3.4 1.5 2.8 0.4 3.4 1.9 39 7 47 165 0.7 0 1.1 0.4 04/11/2007 08:00:00 2.7 0.4 3.4 1.9 2.5 0.4 3.4 1.5 2.9 0.3 3.8 2.3 37 5 45 165 0.9 0.1 1.4 0.7 04/11/2007 08:10:00 2.4 0.2 3 1.9 2.2 0.3 2.6 1.5 2.7 0.2 3 2.3 26 4 28 165 2 0.5 2.8 1.1 04/11/2007 08:20:00 2.2 0.2 2.6 1.5 2.1 0.2 2.6 1.5 2.6 0.2 3.4 2.3 23 2 26 165 2.7 0.3 3.3 1.8 04/11/2007 08:30:00 2.1 0.3 2.6 1.5 1.8 0.3 2.6 1.1 2.4 0.2 3 1.9 23 2 25 165 2.8 0.1 3.3 2.3 04/11/2007 08:40:00 1.8 0.2 2.3 1.5 1.4 0.3 1.9 0.7 2 0.2 2.6 1.5 23 3 21 165 2.8 0.1 3 2.6 04/11/2007 08:50:00 1.9 0.2 2.3 1.5 1.5 0.2 1.9 0.7 2 0.2 2.6 1.5 28 4 25 165 2.7 0.1 3 2.3 04/11/2007 09:00:00 1.3 0.3 1.9 0.7 0.8 0.2 1.5 0.4 1.6 0.2 1.9 1.1 35 1 34 165 2.8 0.3 3.8 2.3 04/11/2007 09:10:00 0.7 0.4 1.9 0.4 0.5 0.2 1.5 0.4 1 0.5 1.9 0.4 84 33 135 165 3.7 0.4 4.5 3.3 04/11/2007 09:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0.1 1.1 0.4 111 1 165 165 4.6 0.3 5.5 4.3 04/11/2007 09:30:00 0.6 0.5 2.3 0.4 0.6 0.4 2.3 0.4 0.8 0.7 3 0.4 137 19 148 165 5.9 0.1 6.2 5.5 04/11/2007 09:40:00 1.4 0.5 2.3 0.4 1.2 0.5 2.6 0.4 1.6 0.5 2.6 0.4 143 18 154 165 4.3 0.5 5.5 3.5 04/11/2007 09:50:00 1.9 0.5 3 0.7 1.4 0.6 3 0.4 1.9 0.5 3.4 0.7 138 10 131 165 3.6 0 3.8 3.5 04/11/2007 10:00:00 2 0.5 3.4 0.7 1.5 0.6 3 0.4 2.2 0.4 3.4 1.5 133 11 134 165 3.5 0.1 4 3.3 04/11/2007 10:10:00 1.9 0.5 3 0.4 1.7 0.6 3.4 0.4 1.9 0.4 3 0.7 126 13 114 165 3.6 0 3.8 3.5 04/11/2007 10:20:00 2.3 0.5 3.8 1.5 2.2 0.5 3.8 1.5 2.4 0.5 3.8 1.5 132 12 135 165 3.6 0.1 4.3 3.5 04/11/2007 10:30:00 3.4 0.5 4.9 2.6 3.3 0.5 5.3 2.3 3.3 0.5 4.9 2.3 138 9 145 165 3.2 0.2 3.5 3 04/11/2007 10:40:00 3.3 0.5 4.9 2.3 3.3 0.5 4.9 2.3 3.4 0.5 4.9 2.3 141 8 135 165 3 0 3.5 2.8 04/11/2007 10:50:00 3.2 0.5 4.9 1.9 3.2 0.5 4.6 1.9 3.2 0.6 5.3 1.9 145 10 153 165 3.1 0 3.3 2.8 04/11/2007 11:00:00 3.6 0.6 4.9 2.3 3.5 0.6 4.9 2.3 3.5 0.6 4.9 2.3 150 9 207 165 3.2 0 3.5 3 04/11/2007 11:10:00 3.9 0.5 5.3 2.6 3.9 0.5 5.3 2.6 3.9 0.5 5.7 3 143 11 148 165 3.2 0.1 3.5 2.8 04/11/2007 11:20:00 4.1 0.5 5.3 3 4.1 0.5 5.7 2.6 4.1 0.5 5.7 2.6 147 6 156 165 3.1 0.1 3.5 2.8 04/11/2007 11:30:00 4.4 0.5 5.7 3.4 4.4 0.4 5.7 3.4 4.4 0.5 6.1 3 145 6 154 165 2.9 0.1 3.5 2.6 04/11/2007 11:40:00 4.5 0.4 5.7 3.4 4.5 0.4 5.7 3.4 4.6 0.5 6.1 3 145 7 136 165 2.9 0.1 3 2.6 04/11/2007 11:50:00 4.9 0.4 6.1 3.4 5 0.5 6.5 3.8 5.1 0.5 6.5 3.8 144 6 146 165 2.9 0 3.3 2.6 04/11/2007 12:00:00 5.3 0.6 7.6 3.4 5.4 0.6 7.6 4.2 5.6 0.6 7.6 4.2 142 8 144 165 2.9 0.1 3.3 2.6 04/11/2007 12:10:00 5.2 0.5 6.8 4.2 5.3 0.5 7.2 4.2 5.5 0.5 6.8 3.8 149 7 140 165 2.6 0.1 3 2.3 04/11/2007 12:20:00 5.8 0.6 7.6 3.8 5.9 0.6 7.6 4.6 5.9 0.5 7.6 4.6 135 9 135 165 3.1 0.1 3.5 2.8 04/11/2007 12:30:00 6.9 0.6 8.8 5.3 6.9 0.6 8.8 5.7 6.9 0.6 8 5.7 135 7 128 165 2.5 0.2 3.3 2.3 04/11/2007 12:40:00 7.5 0.8 9.9 5.3 7.5 0.8 9.9 5.7 7.6 0.8 9.9 6.1 141 6 135 165 2.7 0.2 3.3 2.3 04/11/2007 12:50:00 8.3 0.6 9.9 6.1 8.3 0.6 9.9 6.5 8.4 0.6 10.3 6.1 137 6 128 165 2.4 0.1 2.8 2.3 04/11/2007 13:00:00 8.6 0.7 9.9 6.1 8.6 0.7 9.9 6.1 8.4 0.8 9.9 5.7 135 6 130 165 2.6 0.1 2.8 2.1 04/11/2007 13:10:00 8.8 0.5 10.7 7.2 8.8 0.5 10.7 7.2 8.7 0.6 10.3 6.5 135 5 133 165 2.2 0.2 2.8 1.8 04/11/2007 13:20:00 9 0.5 10.7 7.2 9 0.5 10.3 7.2 8.9 0.6 10.3 6.8 135 5 139 165 2.6 0.2 3.3 2.3 04/11/2007 13:30:00 9.6 0.4 11.1 8 9.5 0.4 11.1 8 9.5 0.6 11.1 7.2 136 4 132 165 2.8 0 3.3 2.6 04/11/2007 13:40:00 9.5 0.6 11.1 6.8 9.4 0.6 11.1 7.2 9.4 0.7 10.7 6.8 136 4 128 165 2.9 0 3 2.6 04/11/2007 13:50:00 9.2 0.6 10.3 6.8 9.1 0.5 10.3 7.2 9 0.6 9.9 6.8 136 4 136 165 2.8 0.2 3.3 2.3 04/11/2007 14:00:00 9.1 0.5 10.3 6.8 9.1 0.5 10.3 6.8 9 0.6 10.3 7.2 137 4 141 165 2.4 0.1 3 2.3 04/11/2007 14:10:00 8.9 0.5 10.3 7.2 8.9 0.5 10.3 7.2 8.9 0.5 10.3 6.5 138 4 138 165 2.4 0.1 3 2.1 04/11/2007 14:20:00 8.3 0.5 9.5 6.5 8.2 0.6 9.5 6.5 8.3 0.6 9.9 6.8 140 5 137 165 2.4 0.2 3 2.1 04/11/2007 14:30:00 8 0.6 9.9 6.1 8 0.6 9.9 6.5 8.2 0.6 9.9 6.1 141 6 136 165 2.3 0 2.8 2.1 04/11/2007 14:40:00 7.6 0.7 9.1 5.3 7.7 0.6 9.1 5.7 7.6 0.7 9.1 4.9 136 9 144 165 2.4 0 2.8 2.1 04/11/2007 14:50:00 8.4 0.5 9.5 6.1 8.4 0.5 9.5 6.5 8.4 0.5 9.5 6.5 138 4 141 165 2.7 0.2 3 2.1 04/11/2007 15:00:00 7.9 0.7 9.9 5.7 7.9 0.6 9.5 6.1 8 0.7 9.9 5.7 140 7 139 165 2.4 0 2.6 2.1 04/11/2007 15:10:00 8 0.6 9.9 6.5 8 0.6 9.9 6.8 8.1 0.7 10.3 6.5 141 6 139 165 2.6 0 2.8 2.3 04/11/2007 15:20:00 8 0.5 9.5 6.5 8 0.5 9.5 6.8 8.1 0.6 9.5 6.1 138 4 136 165 2.5 0.1 2.8 2.3 04/11/2007 15:30:00 7.9 0.6 9.5 6.5 7.9 0.6 9.9 6.1 8 0.6 9.5 6.1 138 5 145 165 2.7 0.1 3.3 2.6 04/11/2007 15:40:00 7.5 0.9 9.9 5.7 7.5 0.8 9.9 5.7 7.5 0.9 9.9 5.3 136 8 138 165 2.9 0 3 2.6 04/11/2007 15:50:00 7.5 0.7 9.1 5.3 7.5 0.7 9.1 5.7 7.4 0.7 9.1 4.9 136 6 144 165 2.5 0.2 3 2.3 04/11/2007 16:00:00 7.4 0.6 8.8 5.7 7.4 0.6 9.1 5.7 7.5 0.7 9.1 5.3 142 6 137 165 2.2 0 2.6 1.8 04/11/2007 16:10:00 7.3 0.5 8.8 5.7 7.4 0.5 8.8 6.1 7.3 0.6 8.8 5.7 137 8 142 165 2.1 0 2.6 1.8 04/11/2007 16:20:00 8 0.6 9.5 6.5 7.9 0.6 9.9 6.5 8.1 0.6 9.5 6.5 144 5 133 165 2.3 0 2.6 2.1 04/11/2007 16:30:00 8.2 0.6 9.5 6.5 8.2 0.6 9.5 6.5 8.2 0.6 9.9 6.5 139 5 135 165 2.4 0.2 2.8 1.8 04/11/2007 16:40:00 7.5 0.4 9.1 6.5 7.4 0.4 9.1 6.5 7.6 0.4 9.1 6.5 142 4 135 165 2.4 0.3 3 1.8 04/11/2007 16:50:00 6.9 0.4 8 5.7 6.9 0.4 8 5.7 7 0.4 8.4 5.3 140 4 136 165 1.8 0 2.1 1.6 04/11/2007 17:00:00 6.9 0.5 8 5.3 7 0.4 8 5.7 7 0.5 8 5.3 140 3 140 165 2 0.3 2.6 1.6 04/11/2007 17:10:00 7.1 0.6 8.8 4.9 7.2 0.5 8.8 6.1 7.1 0.6 8.8 5.3 139 7 124 165 2.3 0.1 2.8 1.8 04/11/2007 17:20:00 7.8 0.7 9.1 4.9 7.8 0.7 9.5 4.9 7.8 0.7 9.1 5.3 141 4 137 165 1.9 0 2.3 1.6 04/11/2007 17:30:00 8.3 0.6 9.5 6.1 8.3 0.5 9.5 6.5 8.2 0.6 9.9 5.7 135 6 140 165 1.8 0 1.8 1.6 04/11/2007 17:40:00 7.5 0.7 9.9 5.3 7.7 0.7 9.9 5.7 7.6 0.7 9.9 5.7 135 9 142 165 1.8 0 2.1 1.6 04/11/2007 17:50:00 7 0.7 8.8 5.3 7.2 0.7 8.8 5.3 7.2 0.7 8.8 5.3 132 7 125 165 1.7 0 2.1 1.4 04/11/2007 18:00:00 6.9 0.8 8.8 4.9 7.2 0.8 9.1 4.9 6.9 0.9 8.4 4.6 120 5 107 165 1.5 0.1 2.3 1.4 04/11/2007 18:10:00 5.8 0.7 7.6 3.8 6.2 0.7 8 4.2 6.1 0.7 8.4 4.2 123 6 127 165 1.4 0.1 1.8 1.4 04/11/2007 18:20:00 5.7 0.9 8 3.8 6.1 0.9 8.4 4.2 5.8 0.9 8.4 3.4 116 7 106 165 1.4 0 1.6 1.4 04/11/2007 18:30:00 6 0.7 8 4.2 6.5 0.7 8.8 4.6 6.1 0.7 7.6 3.8 115 8 107 165 1.3 0 1.6 1.4 04/11/2007 18:40:00 5.8 0.7 7.2 4.2 6.3 0.7 7.6 4.6 5.9 0.8 7.6 3.8 113 6 115 165 1.1 0 1.4 0.9 04/11/2007 18:50:00 6.4 0.5 7.6 4.9 6.9 0.5 8.4 5.7 6.4 0.6 7.6 4.9 111 4 110 165 1.1 0 1.4 0.9 04/11/2007 19:00:00 6.3 0.5 7.6 4.9 6.8 0.5 8 4.9 6.3 0.6 7.6 4.2 113 4 114 165 1.1 0 1.4 0.9 04/11/2007 19:10:00 6.5 0.8 8.4 4.2 6.9 0.8 8.4 4.6 6.1 0.8 8 4.2 113 5 107 165 1.1 0 1.4 0.9 04/11/2007 19:20:00 5.6 0.7 7.6 3.4 6.1 0.7 8 3.8 5.6 0.7 7.6 3 107 6 112 165 1.1 0 1.4 0.9 04/11/2007 19:30:00 5.1 0.7 6.5 2.6 5.5 0.8 6.8 3.4 5.2 0.7 6.5 3.8 106 7 101 165 1.1 0 1.4 0.9 04/11/2007 19:40:00 6.3 1.1 8.8 3.8 6.8 1.1 9.1 4.2 6.3 1 8.4 3.8 104 7 106 165 0.9 0.1 1.4 0.7 04/11/2007 19:50:00 6.9 0.8 8.4 4.9 7.4 0.7 8.8 5.3 6.8 0.7 8.4 4.9 100 4 101 165 0.8 0 0.9 0.7 04/11/2007 20:00:00 5.6 0.6 7.2 3.8 6.1 0.6 7.6 4.6 5.7 0.6 7.2 4.2 91 6 85 165 0.9 0 1.1 0.9 04/11/2007 20:10:00 6.8 1.7 11.1 4.2 7.2 1.5 11.5 4.6 6.8 1.5 10.7 4.6 102 12 111 165 0.8 0.2 1.1 0.2 04/11/2007 20:20:00 4.9 0.6 6.8 3.8 5.2 0.6 7.2 4.2 4.8 0.5 6.5 3.4 104 7 94 165 0.2 0.1 0.7 -0.5 04/11/2007 20:30:00 6 1 8 3.4 6.5 1 8.4 3.4 5.9 1 7.6 3.4 102 7 102 165 0.6 0.1 0.9 0.2 04/11/2007 20:40:00 6.5 1 9.1 4.2 7 1 9.5 4.6 6.6 1 8.8 4.2 103 7 106 165 0.8 0 1.1 0.7 04/11/2007 20:50:00 7.4 1 9.5 4.9 7.8 0.9 9.5 5.3 7.3 1 9.5 5.3 107 6 105 165 0.8 0.1 1.1 0.4 04/11/2007 21:00:00 6.3 0.9 8.4 4.6 6.8 0.9 8.8 4.6 6.4 1 9.1 4.6 101 6 106 165 0.8 0 0.9 0.2 04/11/2007 21:10:00 6.1 0.7 8 3.4 6.6 0.7 8.4 4.6 6.2 0.7 7.6 4.6 90 6 89 165 0.8 0.1 0.9 0.2 04/11/2007 21:20:00 6.9 0.8 8.8 4.2 7.5 0.8 9.1 4.9 7 0.8 8.8 4.6 95 6 96 165 0.8 0 1.1 0.7 04/11/2007 21:30:00 7.5 0.8 9.5 5.3 8 0.7 10.3 6.1 7.4 0.8 9.1 5.3 97 7 97 165 0.8 0 1.1 0.7 04/11/2007 21:40:00 7.3 1 9.5 4.6 7.8 0.9 9.9 5.3 7.3 0.9 9.1 4.9 100 6 105 165 0.8 0 1.1 0.2 04/11/2007 21:50:00 7.4 0.8 9.9 5.3 7.9 0.8 9.9 5.7 7.5 0.8 9.9 5.3 99 6 98 165 0.8 0 1.1 0.7 04/11/2007 22:00:00 7.7 0.8 9.5 6.1 8.2 0.7 9.9 6.5 7.8 0.8 9.9 5.7 89 7 91 165 0.8 0 0.9 0.7 04/11/2007 22:10:00 7.6 1.2 9.9 4.6 8 1.1 10.3 4.6 7.5 1.1 9.9 4.9 97 7 91 165 0.8 0 0.9 0.7 04/11/2007 22:20:00 7.4 1 9.5 5.3 7.8 0.9 9.9 5.3 7.3 0.9 9.5 5.3 97 6 98 165 0.8 0.1 1.1 0.2 04/11/2007 22:30:00 6.9 0.9 9.5 4.6 7.4 0.9 9.5 4.6 6.9 0.9 9.1 4.6 101 6 103 165 0.6 0.2 0.9 0.2 04/11/2007 22:40:00 8.1 1 9.9 4.9 8.5 1 9.9 5.3 7.9 1 9.9 4.9 96 6 99 165 0.7 0.2 1.1 0.2 04/11/2007 22:50:00 8.3 1.7 11.8 4.9 8.7 1.6 12.2 5.3 8.2 1.6 11.5 5.3 97 7 98 165 0.8 0.1 1.1 0.2 04/11/2007 23:00:00 8 1 10.7 5.3 8.4 1 11.1 5.7 7.8 1 10.3 5.7 95 7 88 165 0.8 0 1.1 0.9 04/11/2007 23:10:00 8.2 1.3 11.1 5.3 8.6 1.3 11.5 5.3 8 1.3 10.7 4.9 96 7 104 165 0.8 0 1.1 0.4 04/11/2007 23:20:00 8.7 0.8 10.3 6.8 9 0.7 10.7 6.8 8.4 0.7 10.3 6.1 95 5 90 165 0.8 0 1.1 0.2 04/11/2007 23:30:00 8.4 0.9 10.3 5.7 8.7 0.8 10.7 6.1 8 1 10.3 5.7 106 7 105 165 0.8 0.1 1.1 0.2 04/11/2007 23:40:00 8.6 1 11.1 5.7 8.9 0.9 11.1 6.1 8.2 1 10.7 6.1 112 6 111 165 0.8 0 1.1 0.2 04/11/2007 23:50:00 8.3 0.8 10.3 5.7 8.6 0.8 10.7 5.7 8.1 0.8 9.9 6.1 107 5 102 165 0.8 0 1.1 0.7 04/12/2007 00:00:00 8.6 1.1 10.3 4.9 8.9 1.1 11.1 5.3 8.3 1.1 10.3 4.9 109 5 103 165 0.8 0.1 1.1 0.2 04/12/2007 00:10:00 8.4 1.2 11.8 4.9 8.7 1.1 12.6 4.9 8 1.3 10.7 4.9 109 6 94 165 0.8 0 1.1 0.2 04/12/2007 00:20:00 8.1 1.1 11.1 5.7 8.5 1 11.5 6.1 8 1 10.7 5.7 105 5 107 165 0.8 0 1.1 0.7 04/12/2007 00:30:00 6.9 1 9.5 4.6 7.4 1 9.5 4.9 6.9 0.9 9.5 4.9 105 7 102 165 0.8 0 1.1 0.7 04/12/2007 00:40:00 8.9 1.1 11.1 6.1 9.2 1 11.5 6.5 8.4 1.1 10.7 5.3 107 5 117 165 0.9 0 1.1 0.7 04/12/2007 00:50:00 7.7 1.2 10.7 4.9 8.1 1.1 11.1 5.3 7.5 1.1 10.7 5.3 103 7 105 165 0.9 0 1.1 0.7 04/12/2007 01:00:00 7 1 8.8 4.2 7.4 1 9.5 4.6 6.9 1 9.1 4.6 101 8 108 165 0.8 0.1 1.1 0.2 04/12/2007 01:10:00 7.3 0.9 9.5 4.9 7.7 0.9 9.9 5.3 7 0.9 9.1 4.9 100 7 102 165 0.8 0.1 1.1 0.2 04/12/2007 01:20:00 8.4 1.1 10.7 6.1 8.7 1 11.1 6.5 7.9 1 11.1 5.7 105 7 104 165 0.8 0.1 1.1 0.2 04/12/2007 01:30:00 8.1 1.3 12.6 4.2 8.4 1.2 12.6 4.2 7.8 1.1 11.5 4.6 108 7 107 165 0.8 0 1.1 0.7 04/12/2007 01:40:00 8.5 1 11.5 5.7 8.8 0.9 11.8 6.1 8 1 11.1 5.3 106 7 109 165 0.8 0 1.1 0.4 04/12/2007 01:50:00 8.5 1.2 11.8 4.6 8.8 1.1 11.8 5.7 8.1 1.1 11.5 4.9 103 8 104 165 0.8 0.1 1.1 0.4 04/12/2007 02:00:00 8 0.8 10.3 5.7 8.4 0.7 10.3 5.7 7.7 0.8 9.9 5.3 97 6 103 165 0.8 0.1 1.1 0.4 04/12/2007 02:10:00 7.4 1 9.9 5.3 7.9 1 10.3 5.7 7.4 1 9.5 5.3 86 8 81 165 0.7 0.2 0.9 0.2 04/12/2007 02:20:00 6.4 1.1 9.5 4.2 6.9 1.1 9.5 4.2 6.5 1.1 9.5 3.8 74 12 98 165 0.7 0.2 1.1 0.2 04/12/2007 02:30:00 6.1 0.9 8.4 3.8 6.6 1 8.8 4.2 6.3 0.8 8.4 4.2 68 8 73 165 0.7 0 0.9 0.4 04/12/2007 02:40:00 6.9 0.9 8.8 4.2 7.4 0.9 9.5 4.9 7.1 0.8 9.5 4.6 73 7 74 165 0.8 0.1 0.9 0.7 04/12/2007 02:50:00 6.4 1.1 9.5 4.2 6.8 1.1 9.5 4.2 6.5 1 9.5 4.2 66 7 73 165 0.7 0 0.9 0.4 04/12/2007 03:00:00 6.1 1.1 8.8 3.8 6.5 1.1 8.8 3.8 6.2 1.1 9.1 3.8 61 9 63 165 0.7 0.1 1.1 0.2 04/12/2007 03:10:00 6.5 1.1 9.1 4.2 6.7 1 9.1 4.6 6.4 1 9.1 4.2 42 8 39 165 0.7 0.1 0.9 0.2 04/12/2007 03:20:00 6.9 1 9.1 4.2 7.2 1 9.5 4.6 6.9 1 9.5 4.2 51 11 37 165 0.7 0.1 0.9 0.2 04/12/2007 03:30:00 6.3 0.9 8.8 3.8 6.8 0.9 9.1 4.2 6.4 0.9 8.4 4.2 55 6 56 165 0.7 0.1 0.9 0.2 04/12/2007 03:40:00 6.2 0.8 9.1 4.6 6.7 0.8 9.1 4.6 6.3 0.8 8.4 4.2 65 14 57 165 0.7 0.1 0.9 0.2 04/12/2007 03:50:00 6.6 1.1 9.5 4.2 7.1 1.1 9.9 4.6 6.6 1 9.5 4.6 84 10 101 165 0.4 0.1 0.9 -0.1 04/12/2007 04:00:00 6.8 0.9 9.5 4.6 7.3 0.9 9.9 4.9 6.9 0.8 9.1 4.9 82 11 75 165 0.4 0.2 0.9 -0.3 04/12/2007 04:10:00 7.2 0.8 9.1 4.9 7.7 0.8 9.5 5.3 7.2 0.8 9.1 4.9 63 8 57 165 0.5 0 0.7 -0.1 04/12/2007 04:20:00 6.1 0.8 8.4 4.2 6.5 0.8 8.8 4.6 6.3 0.8 8.8 4.6 65 8 60 165 0.5 0 0.7 -0.1 04/12/2007 04:30:00 6.1 1 9.5 4.2 6.6 1.1 9.9 4.6 6.3 1 8.8 4.2 62 8 68 165 0.5 0 0.9 -0.1 04/12/2007 04:40:00 6.6 1 9.5 4.2 7.1 1 9.9 4.6 6.7 1 9.5 4.6 62 9 79 165 0.6 0 0.9 -0.1 04/12/2007 04:50:00 6.7 1 9.9 4.6 7.1 1 10.3 4.9 6.7 1 9.1 4.6 57 8 53 165 0.6 0 0.9 -0.1 04/12/2007 05:00:00 7 1.2 9.9 3.8 7.3 1.2 10.3 4.2 7 1 9.9 4.2 59 9 65 165 0.6 0 0.9 0.4 04/12/2007 05:10:00 6.6 1 9.1 4.6 6.9 1 9.5 4.6 6.6 1 9.1 4.6 57 8 62 165 0.5 0 0.7 0.4 04/12/2007 05:20:00 5.8 0.9 8.4 3.8 6.1 1 8.4 3.8 5.7 0.9 8.4 3.8 56 9 52 165 0.5 0 0.7 0.2 04/12/2007 05:30:00 7.2 1.2 10.7 4.2 7.5 1.2 11.1 4.6 7.1 1.1 9.9 4.6 56 8 60 165 0.5 0 0.7 0.2 04/12/2007 05:40:00 7.1 1 9.5 4.9 7.5 1 9.9 5.3 7.1 1 9.1 4.2 60 7 63 165 0.4 0 0.7 0.2 04/12/2007 05:50:00 7.1 1.1 9.9 4.9 7.4 1 9.5 5.3 7 1 9.1 4.9 44 9 41 165 0.5 0 0.7 0.2 04/12/2007 06:00:00 7.4 0.9 9.9 4.9 7.6 0.8 10.3 5.3 7.4 0.8 9.5 5.3 38 6 46 165 0.6 0 0.9 0.4 04/12/2007 06:10:00 6.6 0.9 9.5 4.2 6.9 1 9.9 4.2 6.5 0.9 9.1 4.2 45 9 42 165 0.8 0 0.9 0.7 04/12/2007 06:20:00 9.1 2.5 14.9 4.6 9.4 2.4 14.9 4.9 8.9 2.3 14.9 4.6 70 12 73 165 0.5 0.3 0.9 -0.1 04/12/2007 06:30:00 8.2 2.1 13.7 4.6 8.5 2 14.1 4.6 8 2 13.3 4.6 62 11 79 165 -0.1 0 0.2 -0.3 04/12/2007 06:40:00 8.8 1.1 11.1 6.1 9 1.1 11.1 6.1 8.5 1.1 11.1 5.3 64 10 74 165 0.1 0 0.2 -0.1 04/12/2007 06:50:00 7 1.1 9.5 4.6 7.2 1.1 9.5 4.6 6.9 1 9.1 4.6 46 8 43 165 0.1 0 0.2 -0.5 04/12/2007 07:00:00 7.2 1.2 9.9 4.2 7.4 1.2 9.9 4.6 6.9 1.2 9.9 3.8 43 7 23 165 0.2 0.1 0.4 -0.3 04/12/2007 07:10:00 7.6 1.1 10.3 4.2 7.8 1.1 10.7 4.2 7.6 1.1 10.3 4.6 41 7 40 165 0.4 0 0.7 0.2 04/12/2007 07:20:00 6.7 1.2 9.9 4.2 7 1.2 10.3 4.6 6.8 1.1 9.5 4.6 44 8 39 165 0.6 0 0.9 0.2 04/12/2007 07:30:00 5.9 1 8.4 3.4 6.2 1 8.4 3.4 6 0.8 8.4 4.2 46 10 28 165 0.6 0 0.9 0.2 04/12/2007 07:40:00 6.5 1 8.8 3.8 6.8 1 9.1 3.8 6.6 0.9 8.8 4.2 48 9 42 165 0.7 0 0.9 0.7 04/12/2007 07:50:00 7.7 1.5 11.1 4.6 7.9 1.5 11.5 4.9 7.7 1.5 11.1 4.9 50 10 62 165 0.9 0 1.1 0.4 04/12/2007 08:00:00 6.7 1.3 10.3 3.8 7 1.2 10.3 4.2 6.9 1.3 9.5 3.8 47 10 58 165 1 0 1.4 0.7 04/12/2007 08:10:00 6.9 1.2 9.9 4.6 7.1 1.1 10.3 4.6 7 1 10.7 4.9 43 8 37 165 1.1 0.1 1.4 0.4 04/12/2007 08:20:00 6.9 1.2 9.5 4.2 7 1.1 9.5 4.2 7 1.1 9.5 4.2 43 8 30 165 1.2 0.1 1.4 0.7 04/12/2007 08:30:00 6.6 1.8 11.8 3 6.7 1.7 12.2 3.4 6.7 1.6 12.2 3.4 50 14 43 165 1.2 0.2 1.4 0.7 04/12/2007 08:40:00 6.4 1.3 9.5 3.8 6.6 1.3 9.9 4.2 6.5 1.2 9.5 4.2 51 10 52 165 1.2 0.1 1.4 0.7 04/12/2007 08:50:00 7.2 1.3 10.7 4.2 7.3 1.2 10.7 4.6 7 1.2 10.3 4.6 57 10 43 165 1.2 0.2 1.6 0.7 04/12/2007 09:00:00 8.5 1.5 11.8 4.9 8.6 1.5 12.2 4.9 8.5 1.5 13 4.6 66 11 68 165 1.7 0.3 2.3 0.9 04/12/2007 09:10:00 8.9 1.5 12.6 4.2 9 1.5 13 4.6 8.6 1.5 12.2 4.9 63 9 73 165 1.8 0 2.3 1.6 04/12/2007 09:20:00 9.5 1.6 13.3 5.3 9.5 1.7 13.3 4.9 9.2 1.6 13.3 5.3 55 8 50 165 1.8 0.2 2.1 1.4 04/12/2007 09:30:00 9.7 1.8 14.1 4.9 9.8 1.9 14.5 5.3 9.4 1.7 13.7 5.7 58 8 50 165 1.7 0.1 2.1 1.4 04/12/2007 09:40:00 9.2 1.6 13.3 4.9 9.2 1.6 14.1 5.3 9.1 1.6 13 5.3 50 11 63 165 1.8 0.1 1.8 1.4 04/12/2007 09:50:00 8.8 1.5 12.2 4.9 8.8 1.5 12.6 5.3 8.7 1.5 12.2 5.3 43 9 52 165 1.7 0 1.8 1.4 04/12/2007 10:00:00 9 1 11.5 6.1 9 1 11.5 6.1 8.6 1.1 11.5 4.9 42 9 34 165 1.7 0 1.8 1.1 04/12/2007 10:10:00 8.4 1.5 11.8 4.9 8.4 1.5 11.8 4.9 8.4 1.4 11.8 5.7 34 10 39 165 2 0.1 2.3 1.6 04/12/2007 10:20:00 10.1 1.5 13.7 6.1 10 1.5 14.1 5.7 9.8 1.7 14.9 6.1 33 9 29 165 1.8 0.2 1.8 1.1 04/12/2007 10:30:00 11.2 1.1 13.7 8.4 11.1 1.1 14.1 8 10.8 1.2 13.7 6.8 35 7 44 165 1.7 0 1.8 0.9 04/12/2007 10:40:00 10.8 1.5 14.5 6.1 10.8 1.5 14.5 6.1 10.6 1.4 13.7 7.2 34 7 41 165 1.7 0 1.8 1.6 04/12/2007 10:50:00 10.7 1.3 14.1 6.8 10.6 1.3 14.1 6.8 10.6 1.3 14.5 7.6 33 8 37 165 1.9 0.1 2.3 1.4 04/12/2007 11:00:00 10.6 1.2 13.7 7.2 10.5 1.2 14.1 7.2 10.4 1.3 14.1 6.5 32 8 25 165 2.3 0 2.6 1.6 04/12/2007 11:10:00 10.8 1.7 14.9 6.5 10.7 1.7 15.3 6.5 10.4 1.8 15.6 5.7 34 9 39 165 2.3 0 2.6 1.8 04/12/2007 11:20:00 11 1.7 14.9 7.2 10.9 1.8 15.3 7.2 10.7 1.7 15.6 7.6 33 8 34 165 2 0.1 2.3 1.6 04/12/2007 11:30:00 11.9 1.6 15.6 8 11.8 1.7 16.1 7.2 11.8 1.7 15.3 8 32 7 32 165 2.3 0.1 2.6 1.6 04/12/2007 11:40:00 11 1.7 14.9 6.8 10.9 1.8 15.3 6.1 10.8 1.8 15.3 6.1 30 9 33 165 3 0.4 3.5 2.1 04/12/2007 11:50:00 11.3 1.6 15.3 7.6 11.1 1.6 14.9 7.2 10.8 1.6 15.6 7.2 32 8 31 165 2.8 0.2 3.5 2.3 04/12/2007 12:00:00 11 1.7 14.9 6.5 10.9 1.7 14.9 6.8 10.6 1.8 15.6 6.8 32 8 40 165 2.4 0.2 2.8 1.8 04/12/2007 12:10:00 11.1 2.1 16.1 6.8 11 2.2 16.4 6.5 11 2.1 16.4 6.5 34 8 33 165 2.3 0.3 2.8 1.6 04/12/2007 12:20:00 10.6 1.7 15.3 6.1 10.5 1.7 15.6 6.5 10.3 1.7 15.3 6.5 34 9 39 165 2.6 0 3 2.3 04/12/2007 12:30:00 10.6 1.5 13.7 6.8 10.5 1.5 13.7 6.5 10.2 1.5 13.3 5.7 32 10 47 165 2.6 0.1 2.8 2.1 04/12/2007 12:40:00 10.8 1.6 14.5 6.8 10.7 1.7 14.5 5.7 10.5 1.7 14.9 5.7 28 9 11 165 2.6 0.1 2.8 2.1 04/12/2007 12:50:00 10.8 1.6 14.9 6.8 10.7 1.7 15.3 6.5 10.5 1.7 14.5 6.5 33 9 25 165 2.4 0.2 2.8 1.8 04/12/2007 13:00:00 10.7 1.5 15.6 6.8 10.5 1.5 15.6 6.5 10.4 1.4 14.1 6.8 30 9 29 165 2.6 0.2 2.8 1.8 04/12/2007 13:10:00 10.7 1.4 14.5 6.8 10.6 1.5 14.9 6.8 10.4 1.6 14.9 6.8 33 10 41 165 2.5 0.2 2.8 2.1 04/12/2007 13:20:00 11.1 1.4 14.9 7.2 10.9 1.5 14.5 7.2 10.8 1.5 14.1 6.1 24 7 23 165 2.2 0.2 2.8 1.6 04/12/2007 13:30:00 11 1.2 13.7 7.6 10.8 1.3 13.3 6.5 10.7 1.3 13.7 6.8 23 7 22 165 2.3 0.2 2.8 1.6 04/12/2007 13:40:00 10.3 1.2 13 6.8 10.1 1.3 13.3 6.5 9.9 1.2 13.3 7.2 25 7 26 165 2.6 0.1 2.8 1.8 04/12/2007 13:50:00 11.4 2 16.8 6.8 11.2 2 16.8 6.8 11 2 16.8 6.5 25 8 28 165 2.2 0.3 2.8 1.6 04/12/2007 14:00:00 11.4 1.7 14.9 7.2 11.3 1.7 14.9 7.2 10.8 1.7 14.9 6.1 27 8 27 165 2.2 0.2 2.6 1.8 04/12/2007 14:10:00 10 1.3 13.7 6.5 9.8 1.3 13.7 6.5 10 1.3 14.1 6.5 26 8 29 165 2.5 0 2.8 2.1 04/12/2007 14:20:00 12.1 1.6 15.3 8 11.8 1.7 15.3 7.6 11.7 1.7 16.4 7.6 24 8 19 165 2.1 0.2 2.8 1.6 04/12/2007 14:30:00 11.1 1.5 16.1 7.2 10.8 1.5 15.6 6.5 10.7 1.5 14.1 7.2 25 9 15 165 2 0.1 2.3 1.4 04/12/2007 14:40:00 12.2 1.6 16.4 8.4 12 1.7 16.4 8 11.7 1.5 16.1 8.8 24 7 25 165 2 0.1 2.3 1.4 04/12/2007 14:50:00 12.5 1.5 16.4 8.4 12.3 1.7 16.1 7.6 12 1.5 15.3 8.4 23 7 23 165 2.3 0.1 2.6 1.6 04/12/2007 15:00:00 12.4 1.7 16.1 8.4 12 1.7 15.6 7.6 12 1.6 15.6 8 22 8 18 165 2.3 0.1 2.6 1.8 04/12/2007 15:10:00 12.6 1.6 16.1 8.8 12.3 1.7 16.1 8.4 12.4 1.8 16.4 8.4 23 8 24 165 2.1 0 2.6 1.8 04/12/2007 15:20:00 12.1 1.7 15.3 7.6 11.9 1.8 15.3 7.2 11.8 1.7 16.1 8 21 7 26 165 2.1 0 2.3 1.8 04/12/2007 15:30:00 11.9 1.5 15.3 7.2 11.5 1.7 15.3 5.7 11.6 1.5 15.3 7.6 20 8 19 165 2 0.1 2.3 1.6 04/12/2007 15:40:00 11.3 1.7 15.6 6.8 10.9 1.7 15.3 6.5 10.9 1.5 14.9 6.8 20 9 20 165 1.8 0 1.8 1.6 04/12/2007 15:50:00 12.4 1.8 16.8 8.4 12.1 1.9 16.8 7.2 12.1 1.7 17.6 8.4 22 8 21 165 1.9 0 2.1 1.6 04/12/2007 16:00:00 12.6 1.5 15.6 8.8 12.4 1.6 16.1 8 12.4 1.6 16.1 8.4 23 8 25 165 2 0 2.3 1.8 04/12/2007 16:10:00 11.7 1.4 14.5 8 11.4 1.5 14.5 7.2 11.2 1.7 15.3 6.8 23 9 25 165 2 0 2.3 1.6 04/12/2007 16:20:00 11.8 1.5 14.9 7.2 11.5 1.5 14.9 6.8 11.5 1.5 14.5 7.2 21 7 25 165 2 0 2.3 1.6 04/12/2007 16:30:00 11.8 1.5 14.9 8.4 11.4 1.6 15.3 7.2 11.2 1.6 14.9 7.2 19 7 25 165 2 0 2.3 1.6 04/12/2007 16:40:00 11.8 1.5 15.6 8 11.1 1.7 15.6 6.5 11.4 1.4 15.6 7.6 17 7 26 165 1.9 0 2.1 1.6 04/12/2007 16:50:00 12.6 1.7 16.1 7.2 12 1.8 15.6 6.8 12.2 1.7 16.1 7.2 19 8 16 165 1.9 0 2.1 1.6 04/12/2007 17:00:00 13.7 1.3 17.2 9.9 12.1 2.1 16.4 6.1 13.4 1.4 17.9 9.9 13 7 11 165 1.9 0 2.3 1.6 04/12/2007 17:10:00 12.8 1.4 15.6 8.8 11.6 1.8 15.6 6.5 12.4 1.5 16.4 7.6 15 7 13 165 1.9 0.1 2.1 1.4 04/12/2007 17:20:00 11.7 1.4 15.3 8 10.5 1.9 15.3 5.7 11.4 1.5 15.6 7.6 14 9 25 165 1.9 0 2.1 1.6 04/12/2007 17:30:00 11.6 1.1 14.1 8.8 10.1 1.5 14.1 5.3 11.3 1.2 14.5 8 13 8 28 165 1.9 0.1 2.1 1.4 04/12/2007 17:40:00 11.9 1.2 15.3 7.6 10.6 1.6 14.1 5.3 11.6 1.2 14.5 8.8 14 8 9 165 1.9 0 2.1 1.4 04/12/2007 17:50:00 11.8 1.3 14.9 7.6 11.1 1.5 14.9 6.8 11.3 1.3 14.5 8.4 17 8 29 165 2 0 2.3 1.6 04/12/2007 18:00:00 12.5 1.1 15.3 8.8 10.4 2 14.5 6.1 12.2 1.2 14.9 8.8 11 8 3 165 2 0 2.3 1.6 04/12/2007 18:10:00 12.4 1.4 15.3 9.1 9.6 1.5 14.1 6.1 12.3 1.5 15.6 8 7 7 10 165 1.9 0 2.3 1.6 04/12/2007 18:20:00 10.6 1 13.7 8 9.3 1.5 13.7 5.7 10.3 1.2 13.7 7.6 13 8 29 165 1.9 0 2.1 1.8 04/12/2007 18:30:00 13.3 1.5 16.8 9.1 12.3 1.9 16.4 6.1 12.9 1.5 16.1 9.1 17 9 22 165 1.2 0.3 1.8 0.9 04/12/2007 18:40:00 12 1.5 14.9 8 10.4 1.7 14.9 5.3 11.6 1.4 14.9 8 12 7 18 165 0.9 0 1.1 0.9 04/12/2007 18:50:00 13.6 1.9 17.9 9.5 12.3 2.6 18.3 5.3 13.4 2 19.1 8.8 15 7 13 165 0.9 0 1.1 0.7 04/12/2007 19:00:00 11.9 1.6 15.6 8 8.8 1.6 13 4.9 11.8 1.7 15.3 7.2 6 7 3 165 0.8 0 0.9 0.7 04/12/2007 19:10:00 12 1.3 15.3 8.8 9.1 1.7 14.5 5.7 12 1.3 15.6 9.1 6 7 20 165 0.9 0 1.1 0.7 04/12/2007 19:20:00 11.6 1.1 14.1 8.4 8.3 1.3 12.6 5.3 11.5 1.1 14.1 8.4 6 6 8 165 1.1 0 1.4 0.9 04/12/2007 19:30:00 12.4 1.1 15.3 9.1 9 1.6 14.1 5.7 12.4 1.3 16.1 8.8 6 8 11 165 1.3 0 1.4 1.1 04/12/2007 19:40:00 13.1 1.2 16.4 9.9 10.2 2 14.9 6.5 13 1.4 17.2 9.1 7 7 10 165 1.4 0 1.6 1.4 04/12/2007 19:50:00 12.7 1.4 16.1 8.8 9.8 1.8 14.9 5.3 12.6 1.3 15.6 9.5 7 7 0 165 1.4 0 1.6 1.4 04/12/2007 20:00:00 13.6 1.3 17.6 9.9 11.1 1.9 17.2 6.8 13.3 1.3 17.2 10.3 10 8 18 165 1.4 0 1.6 1.4 04/12/2007 20:10:00 14 1.5 17.2 9.5 11.8 2.3 16.4 6.1 13.5 1.5 17.6 9.1 11 7 12 165 1.4 0 1.6 1.4 04/12/2007 20:20:00 11.7 1.1 14.1 8.8 8.9 1.6 13 5.3 11.5 1.3 15.6 8.8 6 7 15 165 1.4 0 1.6 1.4 04/12/2007 20:30:00 12.5 1.7 16.8 8.4 8.5 1.5 13.7 4.9 12.5 1.7 17.2 8.4 2 7 7 165 1.4 0 1.6 1.4 04/12/2007 20:40:00 12.1 1.3 16.4 7.2 8.5 1.5 13.7 5.3 11.9 1.4 16.1 8 1 8 1 165 1.4 0 1.6 1.4 04/12/2007 20:50:00 11.3 1.2 14.5 8.4 8.4 1.8 14.5 4.9 11.2 1.2 14.5 7.6 0 9 351 165 1.5 0 1.6 1.4 04/12/2007 21:00:00 12.3 1.6 15.3 8.4 9.2 1.9 14.5 5.3 12.1 1.7 15.6 8.8 1 9 15 165 1.6 0 1.8 1.4 04/12/2007 21:10:00 11.7 1.7 19.1 8 8.8 2.3 19.1 4.2 11.5 1.7 17.9 8 360 10 354 165 1.6 0 1.8 1.4 04/12/2007 21:20:00 12.4 1.8 16.1 7.2 10.2 2.6 16.4 4.6 12.3 1.7 16.8 8 358 11 11 165 1.7 0 1.8 1.6 04/12/2007 21:30:00 10.3 1.9 15.3 6.1 8.6 2 15.3 4.9 10 1.8 14.9 4.6 6 11 23 165 1.5 0 1.8 1.4 04/12/2007 21:40:00 11.3 1.5 16.4 7.6 8.6 1.8 16.1 4.9 11.1 1.4 17.2 8 4 9 27 165 1.5 0 1.8 1.4 04/12/2007 21:50:00 11.9 1.7 17.2 8.8 9.1 1.8 13.7 5.3 11.9 1.7 16.8 7.6 7 9 354 165 1.8 0 1.8 1.6 04/12/2007 22:00:00 12.2 1.6 16.4 8 8.8 1.5 15.3 4.9 12.2 1.8 16.8 7.2 4 8 14 165 1.8 0 1.8 1.6 04/12/2007 22:10:00 11.4 1.5 16.1 7.6 9.2 1.9 15.3 5.3 11.3 1.5 15.6 7.6 12 9 21 165 1.7 0 1.8 1.6 04/12/2007 22:20:00 11.4 1.2 14.5 8.4 8.1 1.7 14.1 4.6 11.3 1.3 14.9 8 5 7 354 165 1.7 0 1.8 1.4 04/12/2007 22:30:00 11 1.3 13.7 7.6 8.5 1.9 13.7 4.9 11 1.3 14.1 8 2 10 11 165 1.8 0 1.8 1.6 04/12/2007 22:40:00 11.4 2 16.4 7.6 9.1 2.5 16.4 5.3 11.2 2 16.8 6.8 357 9 355 165 1.8 0 1.8 1.6 04/12/2007 22:50:00 11.1 1.7 16.8 7.6 8.6 2.3 15.3 4.6 11 1.5 16.1 7.6 357 8 348 165 1.9 0 1.8 1.8 04/12/2007 23:00:00 13.9 1.6 17.6 9.9 10.5 2.3 17.2 5.7 13.8 1.4 17.9 9.9 356 7 4 165 1.9 0 1.8 1.8 04/12/2007 23:10:00 11.8 1.7 16.1 7.2 9 1.9 14.9 5.3 11.7 1.6 16.1 8.4 355 6 360 165 1.8 0 1.8 1.6 04/12/2007 23:20:00 13.2 1.4 16.8 9.5 9.3 2.1 16.1 5.3 13.1 1.5 17.2 8.8 356 7 347 165 1.8 0 1.8 1.6 04/12/2007 23:30:00 12.9 1.4 16.4 9.9 9.6 2.2 16.1 5.3 12.8 1.3 17.6 9.5 356 7 0 165 1.8 0 1.8 1.6 04/12/2007 23:40:00 12.3 1.5 16.4 8.8 9 2.1 15.3 4.9 12 1.7 17.2 7.6 356 7 358 165 1.7 0 1.8 1.6 04/12/2007 23:50:00 11.9 1.4 15.6 8.8 8.3 1.7 14.1 4.9 11.9 1.5 15.6 9.1 360 8 357 165 1.7 0 1.8 1.6 04/13/2007 00:00:00 12.4 1 15.6 9.9 9 1.7 14.1 5.7 12.4 1.1 16.1 9.1 356 6 358 165 1.6 0 1.8 1.4 04/13/2007 00:10:00 11.5 1.2 14.1 8 8.9 1.7 14.1 5.3 11.5 1.2 13.7 8 354 6 3 165 1.6 0 1.6 1.4 04/13/2007 00:20:00 11.5 1.1 14.5 9.1 9.5 2 14.9 4.9 11.3 1.2 14.5 8.8 352 7 347 165 1.5 0 1.6 1.4 04/13/2007 00:30:00 12 1.3 16.1 8.8 9.8 1.8 14.1 5.3 11.9 1.3 16.4 8.4 354 9 1 165 1.5 0 1.8 1.4 04/13/2007 00:40:00 12.8 1.5 16.1 9.1 9.8 2.1 14.9 5.7 12.9 1.4 16.1 9.1 356 8 358 165 1.6 0 1.8 1.4 04/13/2007 00:50:00 11.6 1.5 16.1 8 9.8 1.7 14.5 5.3 11.6 1.9 16.4 7.2 352 9 1 165 1.5 0 1.6 1.4 04/13/2007 01:00:00 11.1 1.5 15.3 7.6 10.2 2 14.1 5.7 11 1.6 15.3 6.8 348 10 354 165 1.4 0 1.6 1.4 04/13/2007 01:10:00 10.7 1.2 13.3 6.1 9.3 1.6 12.6 5.7 10.7 1.2 13.3 7.2 351 13 8 165 1.5 0 1.6 1.4 04/13/2007 01:20:00 10 1.3 13.3 5.7 9.2 1.6 13 4.6 10 1.4 13 6.1 342 13 335 165 1.5 0 1.6 1.4 04/13/2007 01:30:00 9.9 1.3 13.7 5.7 9.8 1.3 13.3 5.7 9.7 1.5 13 6.1 331 12 332 165 1.5 0 1.6 1.4 04/13/2007 01:40:00 9.6 1.3 13.3 6.8 9.5 1.3 13 6.5 9.3 1.1 12.6 6.1 329 9 319 165 1.5 0 1.6 1.4 04/13/2007 01:50:00 9.5 1.3 13.7 6.5 9.5 1.3 13.3 6.1 9.4 1.3 14.5 5.7 331 12 305 165 1.5 0 1.6 1.4 04/13/2007 02:00:00 9.4 1.2 13 6.1 9.3 1.3 13 5.3 9.2 1.3 12.6 5.7 329 13 309 165 1.6 0 1.8 1.4 04/13/2007 02:10:00 9.5 1.7 14.5 4.9 9.2 1.6 13.3 4.2 9.5 1.5 14.5 5.7 341 13 10 165 1.6 0 1.8 1.4 04/13/2007 02:20:00 8.9 1.6 12.2 4.9 8.3 1.5 11.8 4.9 8.9 1.6 13.3 5.3 332 15 323 165 1.6 0 1.8 1.4 04/13/2007 02:30:00 9.1 1.5 13 3 9 1.7 12.6 3 9 1.6 13.3 3 335 12 325 165 1.6 0 1.8 1.4 04/13/2007 02:40:00 12.1 2.1 19.5 8 12 2.1 19.9 6.8 12.2 2.1 18.7 8.8 327 10 342 165 1.8 0 1.8 1.4 04/13/2007 02:50:00 13.3 1.6 16.8 7.2 13.3 1.7 16.8 7.2 13.4 1.7 17.6 8.8 333 9 336 165 1.8 0 1.8 1.6 04/13/2007 03:00:00 12.2 2 17.9 7.2 11.9 2.2 17.6 6.1 12 2.1 17.2 6.8 334 12 338 165 1.8 0 1.8 1.6 04/13/2007 03:10:00 10 1.9 14.5 4.9 9.7 2.1 14.5 4.9 9.6 1.9 14.1 6.1 332 14 325 165 1.8 0 1.8 1.6 04/13/2007 03:20:00 10.3 1.3 13.7 7.2 10.1 1.3 13.3 6.5 10 1.4 15.3 6.8 332 11 355 165 1.7 0 1.8 1.6 04/13/2007 03:30:00 10.8 2 15.3 5.7 10.6 2 15.3 5.3 10.6 1.8 16.4 5.3 332 12 329 165 1.8 0.1 2.1 1.6 04/13/2007 03:40:00 11.6 1.7 15.6 8 11 2 15.6 4.9 11.4 2 17.6 6.1 331 15 327 165 1.9 0 2.1 1.6 04/13/2007 03:50:00 10.3 1.8 15.3 5.3 10.1 1.9 15.6 4.9 10 2 15.3 4.9 329 11 315 165 1.7 0 1.8 1.6 04/13/2007 04:00:00 10.7 2 17.2 5.3 10.6 1.9 16.4 5.7 10.5 2 16.1 4.9 331 10 352 165 1.7 0 1.8 1.6 04/13/2007 04:10:00 11.3 1.7 16.4 7.6 11.1 1.8 16.8 6.5 11.4 1.7 17.6 7.6 333 12 346 165 1.8 0 1.8 1.6 04/13/2007 04:20:00 11.7 1.5 16.1 7.6 11.3 1.8 15.6 6.1 11.6 1.5 15.3 6.8 332 13 332 165 1.8 0 1.8 1.6 04/13/2007 04:30:00 11.2 1.7 16.1 7.2 11.2 1.8 16.4 7.2 11.1 1.7 16.4 8 333 10 334 165 1.8 0 2.1 1.6 04/13/2007 04:40:00 11.1 1.3 14.5 8 11 1.2 14.5 7.6 10.9 1.3 14.1 8 327 9 323 165 1.8 0 1.8 1.6 04/13/2007 04:50:00 12.1 1.5 16.1 9.1 11.8 1.7 17.2 8 12.3 1.7 17.9 8.4 337 11 340 165 1.9 0 2.3 1.6 04/13/2007 05:00:00 13 1.6 17.9 10.3 12.5 1.9 17.6 7.6 13 1.7 18.7 9.5 335 11 330 165 2 0 2.3 1.8 04/13/2007 05:10:00 10.6 1.5 14.5 6.1 10.6 1.5 14.1 5.3 10.7 1.3 14.1 6.8 334 9 333 165 2 0.1 2.3 1.8 04/13/2007 05:20:00 11.1 1.7 15.6 7.2 11 1.7 15.3 7.2 11 1.9 15.6 7.2 329 12 319 165 2 0 2.3 1.8 04/13/2007 05:30:00 12.4 2.3 19.1 8 12.2 2.4 19.1 6.8 12.2 2.1 17.9 8 332 12 308 165 2 0 2.3 1.8 04/13/2007 05:40:00 14.1 2.1 19.9 9.5 13.7 2.2 19.1 8.4 13.8 2.1 20.2 9.9 334 12 327 165 2.1 0 2.3 1.8 04/13/2007 05:50:00 14.3 1.9 19.5 9.1 14.3 2 18.7 9.5 14.4 2 19.1 9.5 336 11 325 165 2.2 0 2.3 2.1 04/13/2007 06:00:00 15 1.7 19.5 9.9 15 1.7 20.2 9.9 15.1 1.9 19.5 10.3 334 10 349 165 2.3 0 2.6 2.1 04/13/2007 06:10:00 14.2 2.1 19.5 9.5 13.6 2.2 18.7 8.4 14.1 2.1 18.7 9.5 335 14 330 165 2.3 0 2.6 2.1 04/13/2007 06:20:00 13.6 2.3 19.9 5.3 13.4 2.4 19.5 5.7 13.1 2.6 21.4 7.2 331 12 329 165 2.2 0 2.6 1.8 04/13/2007 06:30:00 14.2 1.7 18.3 9.1 13.9 2 19.1 8.4 14 2 18.7 9.5 335 14 350 165 2.4 0 2.6 2.3 04/13/2007 06:40:00 14.7 1.8 19.9 9.9 14.5 1.8 20.2 9.9 14.7 1.9 19.9 11.1 337 10 342 165 2.4 0 2.8 2.3 04/13/2007 06:50:00 13.6 1.8 19.5 9.1 13.4 1.9 19.5 8.8 13.5 2.2 19.5 9.5 338 10 355 165 2.6 0 2.8 2.6 04/13/2007 07:00:00 12.8 1.9 18.3 9.1 12.5 2.1 18.3 7.2 12.3 2.2 18.3 7.2 329 13 335 165 2.7 0 3 2.6 04/13/2007 07:10:00 13 1.5 17.9 8.8 12.6 1.7 17.6 6.8 12.5 1.7 17.6 8.8 325 13 334 165 2.9 0 3 2.6 04/13/2007 07:20:00 12.9 1.5 17.2 9.1 12.7 1.6 17.9 8 12.4 1.7 18.7 8.4 330 12 340 165 2.7 0 2.8 2.6 04/13/2007 07:30:00 13.9 1.7 17.6 8.8 13.7 1.8 17.9 8 13.6 1.7 17.6 8.4 333 13 341 165 2.8 0 3 2.6 04/13/2007 07:40:00 13.7 2.2 20.2 9.1 13.6 2.1 19.9 9.5 13.2 2.4 20.6 8 325 13 335 165 3 0 3.3 2.8 04/13/2007 07:50:00 14.6 2 19.1 8.8 14.1 2.3 18.7 6.5 14.1 2.2 18.3 7.6 327 16 328 165 2.9 0 3.3 2.8 04/13/2007 08:00:00 14.3 1.8 20.2 9.5 14.1 1.8 19.9 9.5 13.6 1.8 19.1 7.2 320 12 307 165 3 0 3.3 2.8 04/13/2007 08:10:00 14.7 2.1 19.9 9.5 14.6 2.1 20.2 9.5 14.2 2.1 19.1 7.6 324 12 305 165 3.4 0.2 3.8 2.8 04/13/2007 08:20:00 13.9 1.7 17.9 9.1 13.8 1.7 17.6 8.8 13.6 1.7 17.9 9.5 329 11 338 165 3.6 0 3.8 3.5 04/13/2007 08:30:00 14.4 2.2 22.9 10.3 14.2 2.2 23.3 8.4 13.7 2.3 21.4 8 324 12 322 165 3.8 0.1 4.3 3.3 04/13/2007 08:40:00 14.1 1.7 18.7 9.1 13.9 1.7 18.3 9.1 13.1 1.7 18.3 8.4 321 13 288 165 4.1 0.1 4.8 3.5 04/13/2007 08:50:00 13 1.8 17.9 9.1 12.6 2 17.6 7.6 12.5 1.7 17.6 8 329 15 313 165 4.3 0.1 4.8 3.8 04/13/2007 09:00:00 12.2 1.7 16.4 7.2 12.1 1.7 16.1 7.2 11.3 1.7 16.1 7.2 324 14 331 165 4.7 0.2 5 4.3 04/13/2007 09:10:00 14 2.1 19.1 8.8 13.8 2.1 19.1 9.1 13.2 2.3 19.1 7.2 325 15 339 165 4.6 0.2 5 4.3 04/13/2007 09:20:00 13.3 2.2 18.7 8 13.1 2.2 18.3 7.6 12.9 2.3 18.3 6.8 326 14 310 165 4.8 0.1 5.2 4.5 04/13/2007 09:30:00 14 1.9 19.5 9.1 13.6 2.2 19.9 8 13.9 2 19.5 8 333 12 339 165 4.7 0 5 4.5 04/13/2007 09:40:00 13.2 2 19.1 8.4 12.9 2.1 18.7 8 12.8 2.2 19.1 7.2 328 15 333 165 4.9 0 5.2 4.5 04/13/2007 09:50:00 11.9 1.7 16.1 8 11.7 1.7 15.6 7.6 11.4 1.7 15.3 7.2 325 10 309 165 4.8 0.1 5 4.5 04/13/2007 10:00:00 12.1 1.9 16.4 7.6 12 2 16.4 7.2 12 2 16.8 8 335 9 341 165 4.6 0.1 5 4 04/13/2007 10:10:00 11.4 1.3 17.2 8.4 11 1.2 15.3 7.6 10.9 1.4 16.8 7.6 330 13 358 165 4.6 0 5 4.3 04/13/2007 10:20:00 11.7 1.5 15.3 6.8 11.5 1.5 14.9 6.8 11.3 1.7 15.6 7.6 326 13 317 165 4.9 0 5 4.5 04/13/2007 10:30:00 11.1 1.7 14.9 7.6 11 1.7 15.3 7.6 10.9 1.7 14.9 6.8 334 9 333 165 4.9 0 5.2 4.5 04/13/2007 10:40:00 12.1 2.2 16.8 6.8 11.4 2.4 16.4 6.1 12 2.2 17.6 6.1 340 12 331 165 4.9 0.1 5.2 4.3 04/13/2007 10:50:00 13.8 1.8 19.1 8.4 13.5 2.3 20.2 6.5 13.6 1.9 17.9 7.2 336 10 347 165 4.8 0.1 5 4.5 04/13/2007 11:00:00 12.3 2.6 18.3 8 12 2.9 18.3 6.1 12.1 2.8 18.3 6.8 335 12 341 165 4.8 0.2 5.5 4.5 04/13/2007 11:10:00 14.4 1.2 17.6 11.5 14.3 1.4 17.6 9.5 14 1.5 17.9 9.9 340 8 340 165 5.4 0 5.7 5 04/13/2007 11:20:00 15 1.4 18.7 10.3 15 1.5 19.1 8.4 14.9 1.3 18.3 11.1 339 6 338 165 5.4 0 5.7 5.2 04/13/2007 11:30:00 14.2 2.3 18.3 8 14.1 2.3 17.9 7.6 14 2.2 18.7 8 337 7 341 165 5.2 0.1 5.5 5 04/13/2007 11:40:00 13 1.7 16.4 8 12.8 1.9 16.8 6.8 12.6 2 17.6 6.1 333 9 325 165 5.5 0.2 6 5.2 04/13/2007 11:50:00 10.8 1.7 16.1 6.1 10.5 1.9 15.6 6.5 10.3 2.1 15.3 5.3 332 14 324 165 5.9 0 6 5.7 04/13/2007 12:00:00 9.7 2.3 14.9 4.2 9.5 2.5 14.9 3.8 9.1 2.6 14.9 3 326 16 336 165 5.9 0.3 6.7 5.5 04/13/2007 12:10:00 9.1 1.2 12.2 6.1 8.9 1.1 12.6 5.7 8.4 1.3 11.1 4.9 329 9 321 165 6.2 0.2 7 5.7 04/13/2007 12:20:00 8.9 1.5 13.7 5.7 8.7 1.5 14.1 4.6 8.2 1.5 12.6 4.6 331 10 338 165 6.2 0.3 7.3 5.7 04/13/2007 12:30:00 8.8 1.4 12.2 4.9 8.7 1.4 11.5 3.4 8.2 1.3 11.5 4.6 327 11 333 165 5.7 0.2 6.7 5.2 04/13/2007 12:40:00 6.9 1.1 9.1 3.4 6.4 1.2 9.1 2.6 6.5 1 8.8 3.4 343 15 336 165 5.7 0.1 6.2 5.5 04/13/2007 12:50:00 7.1 1.7 11.1 3.8 5.8 1.6 9.5 2.6 6.7 1.8 10.7 2.6 2 12 8 165 7.1 0.6 8.3 6.2 04/13/2007 13:00:00 8 1.2 11.1 5.7 6.9 1.5 10.7 3 7.8 1.1 11.1 5.7 8 15 16 165 6.8 0.7 8.3 6 04/13/2007 13:10:00 8.7 1.3 12.6 5.3 7.5 1.7 11.8 3.8 8.7 1.5 11.8 4.9 14 10 20 165 6.5 0.3 7 6 04/13/2007 13:20:00 7.7 1.2 12.2 4.6 6.3 1.6 12.2 3.4 7.7 1.2 11.1 4.2 11 9 23 165 6.9 0.1 7.3 6.5 04/13/2007 13:30:00 6.9 1.2 10.3 4.2 5.4 1.2 9.5 2.6 6.9 1.2 10.3 4.2 5 10 5 165 7.4 0.1 8 7 04/13/2007 13:40:00 6.7 1 9.9 3.4 5.8 1.2 9.9 2.6 6.5 1.1 10.3 3.8 7 15 25 165 7.5 0.2 8 7.3 04/13/2007 13:50:00 6.5 1.3 9.9 3.8 5.6 1.5 9.5 2.6 6.6 1.3 10.7 4.2 11 12 334 165 6.9 0.2 7.5 6.5 04/13/2007 14:00:00 6.1 1 8.4 3.8 5.4 1.3 8 3 5.8 1.1 8.4 2.3 350 19 29 165 7.4 0.2 8.3 7 04/13/2007 14:10:00 6.7 1.2 9.9 3.4 6.7 1.2 9.5 3.4 6.3 1.2 9.5 3.8 327 12 323 165 6.6 0.2 7.5 6.2 04/13/2007 14:20:00 5.9 1.3 9.5 3 5.8 1.4 9.5 2.6 5.8 1.3 9.9 3 334 13 310 165 6.1 0 6.5 6 04/13/2007 14:30:00 6.1 0.8 8.4 3.4 6 0.8 8 3.8 5.6 1.1 8 2.3 321 11 336 165 6.6 0.3 7.3 6.2 04/13/2007 14:40:00 5.3 1 7.6 3.4 5.1 1 7.6 2.6 5.1 0.9 7.2 2.6 343 14 330 165 6.7 0.3 7.5 6.2 04/13/2007 14:50:00 4.7 0.9 7.2 2.3 4.3 1 7.2 1.9 4.6 0.7 6.5 2.6 343 17 323 165 7.6 0.2 8 7.3 04/13/2007 15:00:00 5.9 1.2 8.8 3 5.8 1.2 8.8 3 5.4 1.2 8.8 2.3 327 11 313 165 6.7 0.2 7.5 6 04/13/2007 15:10:00 5.2 1 7.2 2.6 5.1 0.9 7.2 2.3 4.8 1.1 7.6 2.6 323 12 327 165 5.9 0.1 6.2 5.5 04/13/2007 15:20:00 4.7 1.2 8.4 1.9 4.7 1.2 8 1.1 4.6 1.2 8.4 2.3 326 12 320 165 6 0 6.5 5.7 04/13/2007 15:30:00 3.3 0.8 4.9 1.1 2.9 0.8 5.3 1.1 3.3 0.8 5.3 1.5 353 22 344 165 6.4 0.1 7 6 04/13/2007 15:40:00 3.7 0.9 6.5 1.5 3.5 1 6.1 1.5 3.5 0.8 5.7 1.5 354 28 349 165 6.2 0.2 6.7 5.7 04/13/2007 15:50:00 5.7 1.1 8 3.8 5.5 1.2 8.4 2.6 5.7 1.2 8 2.6 28 12 27 165 5 0.3 6 4.8 04/13/2007 16:00:00 5 0.8 7.2 3 5 0.9 7.2 2.6 5.1 0.9 7.6 3 25 8 26 165 5 0.2 5.5 4.5 04/13/2007 16:10:00 6.1 0.8 9.1 4.2 6.1 0.8 9.1 4.6 6.2 0.9 8.8 4.2 28 8 33 165 4.3 0.2 4.8 3.5 04/13/2007 16:20:00 6.7 0.9 8.4 3.8 6.7 1.1 8.4 2.3 6.6 0.9 8.4 4.2 26 7 32 165 4.2 0 4.5 4 04/13/2007 16:30:00 5.8 1 8 3.4 5.7 1.1 8 3.4 5.8 1.1 8.4 3.8 23 7 21 165 4.4 0 4.8 4.3 04/13/2007 16:40:00 5.7 0.5 7.2 4.6 5.7 0.5 7.2 4.2 5.9 0.5 7.2 4.6 28 6 27 165 4.3 0.2 5 3.5 04/13/2007 16:50:00 5 0.6 6.1 3 5.1 0.6 6.1 3 5.2 0.6 6.5 3.4 25 5 26 165 4.4 0 4.8 4.3 04/13/2007 17:00:00 4.7 0.8 6.8 2.3 4.7 1 6.8 2.3 4.9 1 6.8 1.9 26 8 35 165 4.6 0 4.8 4.3 04/13/2007 17:10:00 4.3 0.5 5.7 3.4 4.3 0.5 5.3 3 4.5 0.6 5.7 3 27 8 32 165 4.3 0 4.5 4 04/13/2007 17:20:00 4.6 0.6 6.1 3 4.4 0.8 5.7 1.9 4.9 0.6 6.5 3.4 21 8 21 165 4.6 0 5 4.5 04/13/2007 17:30:00 4.3 0.7 6.5 3 4.3 0.8 6.5 2.6 4.4 0.7 6.8 3 24 6 22 165 4.8 0 5 4.3 04/13/2007 17:40:00 4.4 0.7 6.1 2.6 4.2 0.9 5.7 2.3 4.4 0.8 6.1 1.9 23 9 26 165 4.7 0 5.2 4.3 04/13/2007 17:50:00 4.4 0.5 5.7 3 4.5 0.5 6.1 3 4.6 0.5 6.1 3 24 4 26 165 4.6 0.1 5 4.3 04/13/2007 18:00:00 4.5 0.5 5.3 3 4.6 0.6 5.7 2.6 4.9 0.6 6.1 2.6 26 6 24 165 4.4 0.1 4.8 4.3 04/13/2007 18:10:00 4.4 0.4 5.3 3.4 4.5 0.4 5.3 3.4 4.6 0.5 5.7 3.4 29 5 26 165 4 0 4.3 3.8 04/13/2007 18:20:00 4.2 0.4 5.3 3 4.3 0.4 5.3 3 4.4 0.5 5.3 2.6 33 5 31 165 3.9 0.1 4.3 3.5 04/13/2007 18:30:00 4.8 0.4 5.7 3.4 4.9 0.5 5.7 3.8 4.9 0.7 6.1 2.6 31 4 34 165 3.5 0.1 3.8 3 04/13/2007 18:40:00 4.9 0.2 5.3 4.2 5.1 0.3 5.7 4.6 5.3 0.3 6.1 4.2 31 3 33 165 3.2 0.1 3.5 2.8 04/13/2007 18:50:00 4.7 0.4 5.7 3.4 4.9 0.4 5.7 3.8 5.2 0.3 6.1 4.2 32 4 18 165 3 0.1 3.3 2.8 04/13/2007 19:00:00 4.9 0.4 5.7 4.2 5.1 0.4 6.1 3.8 5.4 0.4 6.1 4.6 34 3 33 165 3 0 3.3 2.8 04/13/2007 19:10:00 4.6 0.3 5.7 3.4 4.7 0.4 5.3 2.6 5 0.3 5.7 4.2 28 6 22 165 2.9 0.1 3.3 2.6 04/13/2007 19:20:00 4.3 0.4 4.9 3.4 3.8 0.7 4.9 2.3 4.8 0.3 5.7 3.8 17 6 21 165 2.7 0.2 3 2.1 04/13/2007 19:30:00 3.8 0.4 4.9 2.3 3.3 0.7 4.9 1.5 3.9 0.8 5.3 1.9 15 6 29 165 2.6 0.2 3 2.1 04/13/2007 19:40:00 2.6 0.4 3.4 1.5 2 0.4 3.4 1.1 2.6 0.5 3.8 1.5 347 17 2 165 2.2 0.2 2.8 1.6 04/13/2007 19:50:00 2.3 0.4 3 1.5 2.1 0.4 3 1.1 2.2 0.5 3.4 0.7 339 21 313 165 1.8 0.2 2.3 1.4 04/13/2007 20:00:00 2.2 0.5 3 0.7 1.5 0.4 3 0.7 2.3 0.6 3.4 0.7 353 11 357 165 1.9 0 2.1 1.8 04/13/2007 20:10:00 1.3 0.3 2.3 0.7 1.1 0.5 2.3 0.4 1.3 0.3 2.3 0.7 344 20 319 165 1.8 0 1.8 1.6 04/13/2007 20:20:00 0.6 0.3 1.1 0.4 0.8 0.3 1.5 0.4 1.2 0.3 1.9 0.4 330 20 4 165 1.8 0 1.8 1.4 04/13/2007 20:30:00 0.6 0.2 1.1 0.4 0.9 0.2 1.5 0.4 0.9 0.3 1.5 0.4 293 10 304 165 1.8 0.1 1.8 1.4 04/13/2007 20:40:00 0.6 0.3 1.5 0.4 0.9 0.4 1.5 0.4 0.9 0.4 1.9 0.4 250 15 237 165 2 0 2.3 1.4 04/13/2007 20:50:00 0.9 0.4 1.9 0.4 1 0.4 1.9 0.4 1.4 0.4 2.3 0.4 210 28 237 165 1.9 0.1 2.3 1.6 04/13/2007 21:00:00 1.6 0.2 1.9 1.5 1.6 0.2 1.9 1.1 2 0.2 2.3 1.5 175 2 176 165 1.6 0 1.8 1.4 04/13/2007 21:10:00 1.6 0.2 1.9 1.1 1.6 0.2 1.9 1.5 2 0.2 2.3 1.5 168 4 176 165 1.4 0 1.6 1.4 04/13/2007 21:20:00 1.2 0.3 1.9 0.7 1.2 0.3 1.9 0.7 1.6 0.3 2.3 1.1 165 2 168 165 1.4 0 1.6 1.4 04/13/2007 21:30:00 0.9 0.2 1.1 0.4 1 0.2 1.5 0.7 1.3 0.2 1.5 1.1 165 0 164 165 1.4 0 1.6 1.4 04/13/2007 21:40:00 0.9 0.2 1.5 0.4 0.9 0.2 1.5 0.4 1.3 0.2 1.5 0.7 172 8 173 165 1.5 0 1.6 1.4 04/13/2007 21:50:00 1.6 0.4 2.3 0.7 1.7 0.4 2.3 0.7 1.7 0.4 2.6 0.7 201 6 203 165 1.6 0 1.6 1.4 04/13/2007 22:00:00 1.7 0.4 2.3 0.4 1.9 0.4 2.6 0.7 2.1 0.3 2.6 1.5 228 15 210 165 1.7 0 1.8 1.4 04/13/2007 22:10:00 0.7 0.3 1.1 0.4 0.8 0.3 1.5 0.4 1.4 0.3 2.6 0.7 261 8 247 165 1.9 0.1 2.1 1.6 04/13/2007 22:20:00 0.5 0.2 1.1 0.4 0.6 0.3 1.1 0.4 0.9 0.3 1.5 0.4 271 5 264 165 2.1 0 2.3 1.8 04/13/2007 22:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.5 0.2 1.1 0.4 274 0 165 165 2.3 0 2.6 2.1 04/13/2007 22:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0.1 1.1 0.4 263 10 165 165 2.3 0.1 2.6 1.8 04/13/2007 22:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 254 0 165 165 2.1 0 2.3 1.8 04/13/2007 23:00:00 0.4 0.2 1.1 0.4 0.4 0.2 1.1 0.4 0.6 0.4 1.9 0.4 244 19 206 165 2.1 0 2.3 1.8 04/13/2007 23:10:00 0.5 0.2 1.5 0.4 0.5 0.3 1.5 0.4 1.3 0.6 2.3 0.4 228 9 210 165 2.1 0 2.6 1.8 04/13/2007 23:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 236 0 165 165 2.4 0 2.6 2.3 04/13/2007 23:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 236 0 165 165 2.3 0 2.6 2.1 04/13/2007 23:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.7 0.4 236 0 165 165 2.4 0.1 2.8 2.1 04/13/2007 23:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.7 0.4 236 0 165 165 2.5 0.1 2.8 2.3 04/14/2007 00:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 236 0 165 165 2.4 0 2.8 2.3 04/14/2007 00:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.6 0.2 1.1 0.4 236 0 165 165 2.7 0 2.8 2.6 04/14/2007 00:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0.1 1.1 0.4 236 0 165 165 2.9 0 3 2.6 04/14/2007 00:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0.2 1.1 0.4 228 4 165 165 2.9 0 3 2.8 04/14/2007 00:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0.2 1.1 0.4 226 0 165 165 2.9 0 3.3 2.8 04/14/2007 00:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.8 0.2 1.1 0.4 226 0 165 165 3 0 3.3 2.8 04/14/2007 01:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.7 0.3 1.1 0.4 226 0 165 165 3.1 0 3.3 2.8 04/14/2007 01:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.7 0.4 226 0 165 165 3.2 0 3.3 3 04/14/2007 01:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 226 0 165 165 3 0 3.3 2.8 04/14/2007 01:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 226 0 165 165 2.8 0 3 2.6 04/14/2007 01:40:00 0.4 0.1 0.7 0.4 0.4 0 0.4 0.4 0.6 0.4 1.5 0.4 242 38 331 165 2.6 0.1 2.8 2.3 04/14/2007 01:50:00 0.7 0.2 1.1 0.4 0.5 0.2 1.1 0.4 1.4 0.2 1.9 1.1 356 1 356 165 2.2 0 2.3 2.1 04/14/2007 02:00:00 1.2 0.3 1.9 0.4 0.6 0.2 1.5 0.4 1.7 0.3 2.3 1.1 358 2 360 165 2.1 0 2.3 1.8 04/14/2007 02:10:00 0.6 0.3 1.1 0.4 0.6 0.2 1.1 0.4 1.2 0.4 1.9 0.7 22 17 1 165 2 0 2.3 1.8 04/14/2007 02:20:00 0.4 0.2 1.1 0.4 0.4 0.1 1.1 0.4 0.8 0.3 1.5 0.4 45 20 35 165 2.3 0.2 2.8 1.8 04/14/2007 02:30:00 1 0.5 1.9 0.4 0.9 0.5 1.9 0.4 1.4 0.7 2.3 0.4 56 13 52 165 2.6 0 2.8 2.3 04/14/2007 02:40:00 1.3 0.2 1.9 0.7 1.2 0.2 1.9 0.7 1.8 0.2 2.3 1.5 35 0 35 165 2.3 0 2.8 2.1 04/14/2007 02:50:00 1.1 0.3 1.5 0.4 1 0.3 1.5 0.4 1.8 0.2 2.3 1.5 35 0 35 165 2.4 0 2.8 2.3 04/14/2007 03:00:00 0.5 0.2 1.1 0.4 0.4 0.2 1.1 0.4 1.2 0.3 1.9 0.4 78 15 87 165 2.7 0 2.8 2.6 04/14/2007 03:10:00 0.8 0.3 1.5 0.4 0.6 0.3 1.1 0.4 1.3 0.3 1.9 0.7 52 14 43 165 2.6 0.1 2.8 2.3 04/14/2007 03:20:00 0.9 0.2 1.5 0.4 0.6 0.2 1.1 0.4 1.4 0.2 1.9 1.1 38 7 43 165 2.1 0 2.3 1.8 04/14/2007 03:30:00 0.7 0.3 1.1 0.4 0.4 0.2 0.7 0.4 1.4 0.2 1.9 1.1 12 7 27 165 2.1 0 2.3 1.8 04/14/2007 03:40:00 0.4 0.2 1.5 0.4 0.4 0.2 1.1 0.4 1.4 0.2 1.9 1.1 19 13 14 165 2.1 0 2.3 1.8 04/14/2007 03:50:00 0.4 0 0.4 0.4 0.5 0.2 1.1 0.4 1.3 0.3 1.9 0.7 44 0 165 165 2.3 0 2.6 2.1 04/14/2007 04:00:00 0.5 0.2 1.1 0.4 0.5 0.2 1.1 0.4 1.3 0.2 1.5 0.7 43 0 44 165 2.2 0 2.6 2.1 04/14/2007 04:10:00 0.4 0 0.4 0.4 0.4 0 0.7 0.4 1.2 0.2 1.5 0.7 43 0 165 165 2 0 2.3 1.8 04/14/2007 04:20:00 0.4 0 0.4 0.4 0.6 0.2 1.1 0.4 1.5 0.2 1.9 1.1 35 5 165 165 2 0 2.3 1.8 04/14/2007 04:30:00 0.8 0.4 1.5 0.4 0.8 0.2 1.1 0.4 1.7 0.2 1.9 1.5 22 2 21 165 2 0 2.3 1.8 04/14/2007 04:40:00 0.5 0.2 1.1 0.4 0.4 0.2 1.5 0.4 1.3 0.3 1.9 0.7 43 21 21 165 2.1 0 2.6 1.8 04/14/2007 04:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.7 0.4 1.5 0.4 110 0 165 165 2.1 0 2.6 1.8 04/14/2007 05:00:00 1.1 0.3 1.9 0.4 1.2 0.3 1.9 0.4 1.6 0.2 1.9 1.1 106 2 110 165 2.1 0 2.3 1.8 04/14/2007 05:10:00 0.8 0.3 1.5 0.4 0.8 0.3 1.5 0.4 1.5 0.4 2.3 0.7 59 30 34 165 2.3 0 2.6 1.8 04/14/2007 05:20:00 0.4 0.1 1.1 0.4 0.4 0.1 1.1 0.4 0.9 0.4 1.9 0.4 59 19 34 165 2.2 0 2.6 2.1 04/14/2007 05:30:00 1.5 0.5 2.3 0.4 1.5 0.5 2.3 0.4 1.8 0.6 2.3 0.4 93 7 98 165 2.1 0 2.3 1.8 04/14/2007 05:40:00 1.2 0.3 1.9 0.4 1.2 0.4 1.9 0.4 1.7 0.3 2.3 1.1 111 2 106 165 2.1 0 2.3 1.8 04/14/2007 05:50:00 1 0.2 1.5 0.7 1 0.2 1.5 0.4 1.5 0.2 1.9 1.1 108 1 107 165 2 0 2.3 1.8 04/14/2007 06:00:00 0.9 0.5 1.9 0.4 1 0.5 1.9 0.4 1.4 0.3 1.9 0.4 107 0 107 165 2 0 2.3 1.8 04/14/2007 06:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.6 0.3 1.5 0.4 108 2 165 165 2 0.1 2.3 1.8 04/14/2007 06:20:00 0.7 0.3 1.5 0.4 0.7 0.3 1.5 0.4 1.3 0.4 1.9 0.4 124 4 126 165 1.9 0 2.3 1.8 04/14/2007 06:30:00 0.5 0.3 1.5 0.4 0.5 0.3 1.5 0.4 1.2 0.3 1.9 0.4 126 15 130 165 1.8 0 2.1 1.6 04/14/2007 06:40:00 0.6 0.3 1.5 0.4 0.5 0.3 1.5 0.4 1.4 0.4 2.3 0.4 149 7 143 165 2 0 2.3 1.8 04/14/2007 06:50:00 0.5 0.3 1.1 0.4 0.4 0.2 1.1 0.4 1 0.3 1.5 0.4 159 4 156 165 2 0 2.3 1.8 04/14/2007 07:00:00 1.2 0.6 2.3 0.4 1.3 0.7 2.3 0.4 1.5 0.7 3 0.4 166 2 169 165 2.3 0 2.6 2.1 04/14/2007 07:10:00 1.1 0.5 2.3 0.4 1.2 0.6 2.3 0.4 1.5 0.5 2.6 0.7 168 9 164 165 2.6 0 2.8 2.3 04/14/2007 07:20:00 0.5 0.3 1.9 0.4 0.5 0.3 1.9 0.4 1.2 0.3 2.3 0.7 159 5 176 165 2.9 0 3.3 2.6 04/14/2007 07:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.6 0.2 1.1 0.4 162 0 165 165 3 0.3 3.5 2.6 04/14/2007 07:40:00 0.6 0.3 1.5 0.4 0.6 0.3 1.5 0.4 1.4 0.3 1.9 0.4 151 5 148 165 3.6 0.1 4 3 04/14/2007 07:50:00 1.1 0.5 2.6 0.4 1 0.6 2.6 0.4 1.8 0.4 2.6 1.1 148 3 147 165 3.2 0.2 3.5 2.6 04/14/2007 08:00:00 1.4 0.3 2.6 0.7 1.4 0.3 2.6 0.7 1.9 0.3 3 1.5 154 7 150 165 3.6 0.1 4.3 3.3 04/14/2007 08:10:00 0.9 0.3 1.5 0.4 0.8 0.3 1.1 0.4 1.4 0.3 1.9 0.4 174 11 164 165 4.2 0.4 5 3.3 04/14/2007 08:20:00 1 0.8 4.2 0.4 0.9 0.8 3.8 0.4 1.4 0.8 4.6 0.4 177 17 165 165 5.2 0.1 5.5 4.8 04/14/2007 08:30:00 1.8 0.4 2.6 0.7 1.5 0.4 2.6 0.4 2.1 0.3 3 1.5 139 7 141 165 4.7 0.1 5.2 4.5 04/14/2007 08:40:00 2.1 0.5 3 1.1 1.6 0.6 3 0.4 2.2 0.5 3.4 1.1 138 10 133 165 4.4 0 4.8 4.3 04/14/2007 08:50:00 2 0.4 3.4 1.1 1.5 0.5 3 0.7 2.2 0.4 3.4 1.1 135 9 146 165 4.4 0 5 4.3 04/14/2007 09:00:00 2.3 0.3 3.4 1.1 1.9 0.4 3 0.4 2.3 0.3 3.4 1.5 135 9 140 165 4 0.3 4.8 3.5 04/14/2007 09:10:00 2.3 0.3 3 1.5 2 0.4 2.6 0.7 2.2 0.3 3 1.5 124 10 150 165 3.1 0.2 3.5 2.8 04/14/2007 09:20:00 2.6 0.3 3.8 1.9 2.2 0.4 3.4 1.1 2.5 0.3 3.4 1.9 127 12 131 165 3.2 0.1 3.5 2.8 04/14/2007 09:30:00 2.5 0.4 3.4 1.1 2.1 0.5 3.4 0.4 2.4 0.4 3.4 0.7 125 16 154 165 3.2 0.2 3.5 2.8 04/14/2007 09:40:00 2.3 0.4 3.4 1.5 2.1 0.4 3.4 1.1 2.2 0.4 3.4 1.5 120 9 126 165 3.3 0 3.5 3 04/14/2007 09:50:00 2.8 0.4 3.8 1.5 2.8 0.4 3.8 1.5 2.8 0.4 3.8 1.9 124 10 137 165 3.1 0.2 3.5 2.8 04/14/2007 10:00:00 2.7 0.4 3.8 1.9 2.7 0.4 3.8 1.5 2.7 0.4 3.8 1.9 130 10 126 165 2.7 0 2.8 2.6 04/14/2007 10:10:00 2.7 0.7 4.6 0.4 2.8 0.6 4.9 0.7 2.8 0.6 4.2 1.1 128 12 140 165 3.5 0.3 4 2.8 04/14/2007 10:20:00 2.6 0.7 4.2 0.4 2.7 0.6 4.2 0.7 2.8 0.5 3.8 0.7 140 12 133 165 3.1 0.2 3.5 2.6 04/14/2007 10:30:00 3.8 0.6 5.7 2.6 3.8 0.6 5.7 2.3 3.8 0.6 5.3 2.3 122 8 112 165 2.5 0.1 2.8 2.3 04/14/2007 10:40:00 4.1 0.5 5.7 2.6 4.1 0.5 5.7 2.3 4 0.6 6.1 2.3 113 9 123 165 2.9 0.4 3.5 2.1 04/14/2007 10:50:00 3.9 0.4 4.9 2.6 4 0.4 4.9 2.6 4 0.5 4.9 2.3 131 10 122 165 2.8 0.2 3.3 2.3 04/14/2007 11:00:00 4.1 0.5 5.7 3 4.1 0.5 5.7 3 4.2 0.5 5.7 3 148 10 152 165 2.6 0.1 2.8 2.1 04/14/2007 11:10:00 4 0.7 6.1 2.3 4.1 0.7 5.7 2.3 4.2 0.6 6.1 2.6 142 9 147 165 3.2 0.5 3.8 2.1 04/14/2007 11:20:00 3.8 0.7 5.7 1.9 3.8 0.7 6.1 1.9 4.2 0.7 6.1 2.3 145 11 163 165 3.7 0.2 4.3 3.3 04/14/2007 11:30:00 3.9 0.7 5.3 2.3 3.8 0.6 5.3 1.9 4.1 0.7 5.7 2.3 141 9 149 165 2.9 0.3 3.3 2.1 04/14/2007 11:40:00 4 0.9 5.7 2.3 4 0.9 6.1 2.6 4 1 6.1 2.3 138 11 150 165 2.5 0.1 2.8 2.1 04/14/2007 11:50:00 5.6 0.4 6.8 4.2 5.6 0.4 6.8 4.2 5.7 0.4 6.8 4.6 143 5 135 165 2.1 0 2.6 1.4 04/14/2007 12:00:00 5.8 0.5 6.8 4.6 5.8 0.4 6.8 4.6 5.9 0.5 7.2 4.6 150 4 147 165 2.3 0 2.6 1.6 04/14/2007 12:10:00 6.1 0.6 7.6 4.6 6.2 0.5 7.6 4.9 6.4 0.5 7.6 4.9 142 7 136 165 3 0.4 3.8 1.8 04/14/2007 12:20:00 5.3 0.9 7.2 3.4 5.4 0.8 7.2 3 5.6 0.9 7.6 3.8 143 7 135 165 3.5 0 3.8 3.3 04/14/2007 12:30:00 4.5 0.6 6.1 2.6 4.4 0.6 6.1 2.3 4.6 0.5 6.1 3 155 7 160 165 3.8 0 4 3.5 04/14/2007 12:40:00 4 0.6 5.7 2.6 3.9 0.6 5.7 2.3 4.1 0.7 5.7 2.6 158 11 160 165 3.8 0.2 4.5 3.5 04/14/2007 12:50:00 4.9 0.8 6.5 2.6 4.8 0.8 6.8 2.6 5.1 0.8 6.5 3.4 157 13 153 165 3.5 0 3.8 3.3 04/14/2007 13:00:00 5.2 0.6 6.8 3.4 5.2 0.6 6.8 3.4 5.5 0.6 7.2 3.8 157 7 171 165 4 0 4.3 3.8 04/14/2007 13:10:00 5.4 0.7 7.6 3.8 5.3 0.7 7.6 3.4 5.5 0.8 8 3 153 12 145 165 4 0.1 4.3 3.5 04/14/2007 13:20:00 7.1 0.8 8.8 4.9 6.9 0.7 8.8 4.9 7.2 0.8 9.1 5.3 155 11 162 165 3.6 0.1 4.3 3.3 04/14/2007 13:30:00 8.3 1.2 10.7 5.3 8.1 1.1 10.3 4.9 8.5 1.2 11.1 6.1 158 13 165 165 3.4 0 3.8 3.3 04/14/2007 13:40:00 9.7 0.4 10.7 8 9.4 0.3 10.7 8 10 0.4 11.1 8.8 166 9 162 165 3.8 0.2 4.3 3.5 04/14/2007 13:50:00 9.4 0.5 10.3 8 9.1 0.5 10.3 7.6 9.6 0.5 11.1 8.4 170 6 175 165 3.9 0.2 4.3 3.5 04/14/2007 14:00:00 9.1 0.5 10.3 7.6 8.8 0.4 9.5 7.6 9.3 0.6 10.7 7.6 170 5 172 165 3.2 0.2 4 2.6 04/14/2007 14:10:00 9 0.4 9.9 8 8.7 0.4 9.9 7.6 9.2 0.5 10.3 7.6 164 12 175 165 3.1 0 3.3 2.8 04/14/2007 14:20:00 8.9 0.4 9.9 7.6 8.7 0.4 9.9 7.6 9.2 0.4 10.3 8 162 7 165 165 3.1 0.1 3.3 2.8 04/14/2007 14:30:00 8.9 0.5 10.3 7.6 8.6 0.5 10.3 7.2 9.2 0.5 10.7 7.6 161 19 163 165 3 0.1 3.5 2.6 04/14/2007 14:40:00 8.8 0.5 9.9 6.8 8.5 0.5 9.9 7.2 9 0.6 10.3 7.2 159 14 156 165 2.9 0.2 3.5 2.3 04/14/2007 14:50:00 8.2 0.6 9.9 6.5 8.1 0.6 9.5 6.5 8.4 0.6 10.3 6.8 154 8 150 165 2.9 0.2 3.5 2.3 04/14/2007 15:00:00 8.6 0.5 9.9 6.8 8.5 0.5 9.9 6.8 8.8 0.5 9.9 7.2 153 4 156 165 3.1 0.2 3.5 2.6 04/14/2007 15:10:00 8.2 0.5 9.5 6.5 8.1 0.5 9.5 6.5 8.4 0.5 9.9 6.5 153 4 150 165 2.8 0 3.3 2.6 04/14/2007 15:20:00 9.3 0.6 10.7 7.2 9.1 0.5 10.3 7.2 9.4 0.6 11.1 7.2 154 4 156 165 2.6 0.2 3 1.8 04/14/2007 15:30:00 9.9 0.4 10.7 8.8 9.7 0.4 10.7 8.4 10.1 0.4 11.1 8.8 153 3 147 165 2.7 0 2.8 2.1 04/14/2007 15:40:00 10.1 0.6 11.8 8.4 9.9 0.6 11.8 8.4 10.3 0.7 11.8 8.4 152 3 148 165 2.7 0.1 3 2.1 04/14/2007 15:50:00 10.7 0.5 11.8 9.5 10.6 0.5 11.5 9.1 10.9 0.6 12.2 9.5 149 3 149 165 2.3 0 2.6 2.1 04/14/2007 16:00:00 10.7 0.8 12.6 8.4 10.5 0.8 12.6 8.4 10.8 1 13 8 154 4 154 165 2.1 0.1 2.6 1.8 04/14/2007 16:10:00 11.7 0.6 13.3 10.3 11.5 0.6 13 9.5 11.8 0.7 13.7 9.5 153 4 154 165 1.7 0.2 1.8 1.4 04/14/2007 16:20:00 12 0.6 13.3 10.7 11.7 0.6 13 9.9 12.3 0.6 13.7 10.7 154 4 153 165 1.5 0.2 1.8 0.9 04/14/2007 16:30:00 11.2 0.7 13 9.5 11.1 0.6 12.6 9.5 11.2 0.8 12.6 8.8 151 3 146 165 1.5 0 1.6 0.9 04/14/2007 16:40:00 11.1 0.5 12.6 9.5 11 0.4 12.2 9.5 11.1 0.6 12.2 8.4 152 3 148 165 1.4 0.1 1.6 0.9 04/14/2007 16:50:00 11.1 0.4 11.8 9.9 10.9 0.4 11.8 9.9 11.3 0.5 12.2 9.5 154 3 150 165 1.2 0 1.4 0.9 04/14/2007 17:00:00 11.2 0.5 12.6 9.5 11 0.5 12.2 9.5 11.5 0.5 13 9.5 154 5 147 165 1.2 0.1 1.6 0.9 04/14/2007 17:10:00 10.7 0.7 12.2 8.4 10.5 0.6 12.2 8.4 11 0.6 12.6 9.1 154 10 157 165 1.2 0 1.4 0.9 04/14/2007 17:20:00 10.4 0.6 11.5 7.6 10.2 0.6 11.5 8 10.6 0.5 11.8 9.1 154 4 153 165 1.1 0 1.4 0.7 04/14/2007 17:30:00 10.1 0.5 11.5 8.4 9.9 0.5 11.1 8.4 10.3 0.6 11.8 8.4 154 3 154 165 1.1 0 1.4 0.7 04/14/2007 17:40:00 9.5 0.6 11.1 7.2 9.4 0.6 10.7 7.2 9.7 0.8 11.1 6.8 152 3 156 165 1 0 1.4 0.4 04/14/2007 17:50:00 8.9 0.5 10.3 7.2 8.9 0.5 10.3 7.2 9.1 0.6 10.7 7.6 152 3 153 165 0.9 0 1.4 0.7 04/14/2007 18:00:00 9.9 0.6 11.8 8.4 9.8 0.5 11.5 8 9.9 0.6 11.5 8 147 4 145 165 0.9 0 1.4 0.9 04/14/2007 18:10:00 10.4 0.5 11.5 9.1 10.4 0.5 11.5 9.1 10.4 0.6 11.8 8.8 145 3 141 165 0.8 0 0.9 0.9 04/14/2007 18:20:00 10.4 0.4 11.1 8.8 10.3 0.4 11.1 9.1 10.5 0.5 11.8 9.1 150 3 148 165 0.8 0 1.1 0.4 04/14/2007 18:30:00 10.2 0.4 11.5 9.1 10.2 0.4 11.1 9.1 10.3 0.5 11.1 8.8 146 3 138 165 0.8 0.1 0.9 0.2 04/14/2007 18:40:00 10 0.5 11.5 8.4 9.9 0.5 11.5 8 10.1 0.6 11.8 8.8 149 5 153 165 0.8 0.1 0.9 0.2 04/14/2007 18:50:00 9.9 0.4 11.1 8.8 9.7 0.4 10.7 8.4 10.1 0.5 11.1 8.4 151 3 153 165 0.7 0.1 0.9 0.2 04/14/2007 19:00:00 9.3 0.7 10.7 7.2 9.3 0.7 10.7 6.8 9.5 0.8 11.1 7.6 148 5 147 165 0.7 0.1 1.1 0.2 04/14/2007 19:10:00 9.5 0.6 10.7 8 9.5 0.6 10.7 7.6 9.6 0.6 11.1 8 147 3 144 165 0.7 0 0.9 -0.1 04/14/2007 19:20:00 9 0.5 9.9 8 9 0.5 9.9 8 9.1 0.6 10.3 7.2 147 4 147 165 0.5 0 0.7 -0.1 04/14/2007 19:30:00 8.7 0.5 10.3 6.8 8.8 0.5 10.3 6.8 8.9 0.6 9.9 6.5 142 6 147 165 0.2 0 0.4 -0.1 04/14/2007 19:40:00 7.2 0.5 8.8 5.3 7.4 0.5 8.4 5.3 7.3 0.6 8.8 4.9 136 5 141 165 0.2 0 0.4 -0.1 04/14/2007 19:50:00 6.5 0.6 8 4.6 6.7 0.6 8 4.2 6.4 0.6 8 4.6 128 5 126 165 0.2 0 0.4 0.2 04/14/2007 20:00:00 7.4 0.9 9.5 5.3 7.6 0.9 9.9 5.7 7.5 0.8 10.3 6.1 129 7 137 165 0.4 0 0.7 0.2 04/14/2007 20:10:00 8.7 1.3 11.5 4.9 8.8 1.2 11.1 5.3 8.8 1.3 11.1 5.3 140 5 145 165 0.5 0 0.7 0.2 04/14/2007 20:20:00 9 0.7 10.7 6.5 9 0.7 10.7 6.8 8.9 0.8 10.3 6.1 135 6 133 165 0.4 0 0.7 0.2 04/14/2007 20:30:00 8.2 1 9.9 5.7 8.4 1 9.9 5.7 8.2 1 9.9 4.9 126 5 128 165 0.3 0 0.7 0.2 04/14/2007 20:40:00 7.7 0.7 9.9 5.7 8 0.7 9.9 6.1 7.7 0.8 9.5 5.3 121 5 126 165 0.3 0 0.7 0.2 04/14/2007 20:50:00 8.6 0.9 11.1 5.7 8.9 1 11.5 6.1 8.4 1.1 11.5 5.7 116 5 117 165 0.4 0 0.7 0.2 04/14/2007 21:00:00 8.7 0.9 11.1 6.5 9 0.9 11.5 7.2 8.5 1 11.8 5.7 113 5 110 165 0.5 0 0.7 0.2 04/14/2007 21:10:00 9.5 0.9 11.8 7.2 9.8 0.9 12.2 6.8 9.2 1 11.1 6.1 110 5 111 165 0.6 0 0.9 0.4 04/14/2007 21:20:00 9.8 0.9 12.2 7.2 10.1 0.9 12.2 8 9.4 1.1 12.2 6.5 109 5 114 165 0.7 0 0.9 0.7 04/14/2007 21:30:00 10 0.8 12.2 6.8 10.3 0.8 12.6 6.8 9.7 0.8 11.8 7.6 112 6 105 165 0.8 0 0.9 0.7 04/14/2007 21:40:00 10.3 0.9 12.2 8 10.6 0.9 13 8 9.9 1.1 13 7.2 114 5 116 165 0.8 0 1.1 0.7 04/14/2007 21:50:00 10.6 1.2 14.1 8 10.9 1.2 14.1 8 10.7 1.3 14.1 7.2 122 6 124 165 0.9 0 1.1 0.9 04/14/2007 22:00:00 10.1 0.9 12.2 8 10.4 0.9 12.6 8 10.2 1.1 12.6 6.8 123 5 128 165 0.8 0 1.1 0.9 04/14/2007 22:10:00 11.2 1.1 14.5 7.6 11.5 1.1 14.5 7.6 11.3 1.2 14.5 7.2 124 5 119 165 0.9 0 1.1 0.9 04/14/2007 22:20:00 11.8 1 14.1 8 12 1 14.5 8.4 12 1.2 14.9 8.4 125 6 126 165 0.8 0 0.9 0.7 04/14/2007 22:30:00 10.5 1.1 13.3 8 10.8 1.1 13.7 8 10.6 1.2 13.3 6.5 121 6 133 165 0.8 0 0.9 0.7 04/14/2007 22:40:00 12.4 1.9 16.4 8.4 12.6 1.8 16.8 8.8 12.3 2 16.8 8 122 8 121 165 0.8 0 0.9 0.7 04/14/2007 22:50:00 11.9 1 15.3 7.6 12.1 1 15.6 8.4 12 1.1 14.5 8.8 123 6 124 165 0.7 0 0.9 0.4 04/14/2007 23:00:00 10.7 1.7 13.7 6.5 11 1.7 14.1 6.1 10.6 1.7 13.7 6.1 117 8 116 165 0.7 0 0.9 0.7 04/14/2007 23:10:00 10.5 1.1 13.7 7.2 10.8 1.2 13.7 7.2 10.6 1.2 14.1 7.6 113 6 114 165 0.6 0 0.9 0.4 04/14/2007 23:20:00 10.3 1 13.3 7.6 10.7 1 13.7 8 10.3 1 13 7.6 110 5 112 165 0.7 0 0.9 0.4 04/14/2007 23:30:00 9.9 0.9 12.6 6.8 10.3 1 13 7.2 9.8 1 12.6 7.2 112 6 99 165 0.7 0 0.9 0.7 04/14/2007 23:40:00 10.2 1.2 13 6.1 10.6 1.2 13.3 5.7 10.1 1.3 13.3 6.1 112 6 108 165 0.7 0 0.9 0.7 04/14/2007 23:50:00 10.4 1 12.6 7.2 10.8 1 13 7.6 10.4 1.2 12.6 6.5 107 5 109 165 0.7 0 0.9 0.7 04/15/2007 00:00:00 10.3 0.9 13 8 10.8 0.9 13.3 8.4 10.3 1 12.6 7.6 106 4 107 165 0.7 0 0.9 0.7 04/15/2007 00:10:00 10.7 0.8 12.6 8.4 11.2 0.8 13.3 8.4 10.7 1 12.6 8.4 105 4 106 165 0.7 0 0.9 0.7 04/15/2007 00:20:00 9.9 0.8 11.8 7.6 10.3 0.9 12.6 6.8 9.9 1 12.2 7.2 105 5 106 165 0.7 0 0.9 0.7 04/15/2007 00:30:00 10.1 0.8 11.8 7.2 10.5 0.9 12.2 7.6 10.1 1 12.2 7.2 104 4 102 165 0.8 0 0.9 0.7 04/15/2007 00:40:00 10.2 0.8 12.2 8 10.7 0.9 12.6 8 10.3 0.9 12.6 8 106 4 107 165 0.8 0 0.9 0.7 04/15/2007 00:50:00 9.9 0.9 12.2 6.8 10.4 1 13 6.8 9.9 1.2 12.6 6.8 105 5 109 165 0.8 0 0.9 0.7 04/15/2007 01:00:00 10.2 0.8 11.8 7.2 10.7 0.8 12.6 7.6 10.2 1 12.2 7.2 108 5 104 165 0.8 0 0.9 0.7 04/15/2007 01:10:00 9.7 0.7 11.8 6.1 10.2 0.7 12.6 6.5 9.7 0.9 11.8 6.8 109 3 110 165 0.7 0 0.9 0.4 04/15/2007 01:20:00 9.9 0.6 11.5 8 10.4 0.7 12.2 8.4 10.1 0.8 12.2 7.6 110 3 109 165 0.8 0 0.9 0.7 04/15/2007 01:30:00 9.4 0.6 11.1 6.8 9.9 0.6 11.5 7.6 9.5 0.8 11.8 6.8 108 1 108 165 0.8 0 0.9 0.7 04/15/2007 01:40:00 9 0.7 11.1 6.8 9.4 0.7 11.8 6.8 9.2 0.9 11.5 6.8 108 0 108 165 0.8 0 0.9 0.7 04/15/2007 01:50:00 8.4 0.6 10.3 6.1 8.9 0.6 10.3 6.5 8.6 0.7 10.7 6.8 108 0 108 165 0.8 0 0.9 0.7 04/15/2007 02:00:00 8.5 0.6 9.9 6.1 9 0.6 10.7 6.5 8.8 0.8 10.7 6.5 108 0 108 165 0.8 0 0.9 0.7 04/15/2007 02:10:00 8.6 0.6 10.3 6.8 9.2 0.7 11.1 7.2 9 0.8 11.5 6.5 108 0 108 165 0.8 0 0.9 0.7 04/15/2007 02:20:00 8.1 0.6 9.9 6.8 8.7 0.6 10.3 7.2 8.4 0.8 10.7 6.1 108 0 108 165 0.8 0 0.9 0.7 04/15/2007 02:30:00 7.7 0.5 8.8 6.1 8.3 0.6 9.5 6.5 8.1 0.6 9.5 6.1 108 0 108 165 0.8 0 0.9 0.7 04/15/2007 02:40:00 7.5 0.6 9.1 5.3 8.1 0.6 9.5 5.3 7.8 0.9 9.5 4.9 108 0 108 165 0.8 0 0.9 0.7 04/15/2007 02:50:00 7.3 0.6 8.8 5.3 7.9 0.6 9.1 5.3 7.7 0.6 9.1 5.7 108 0 108 165 0.8 0 0.9 0.7 04/15/2007 03:00:00 7.2 0.5 8.8 5.7 7.9 0.5 9.1 6.1 7.8 0.8 9.5 5.3 108 0 108 165 0.8 0 0.9 0.7 04/15/2007 03:10:00 7.4 0.6 9.1 6.1 8.1 0.6 9.9 6.8 8 0.6 9.9 6.1 108 0 108 165 0.8 0 0.9 0.7 04/15/2007 03:20:00 7.1 0.5 8.4 5.7 7.8 0.5 9.1 6.5 7.8 0.6 9.1 6.1 108 0 108 165 0.8 0 0.9 0.7 04/15/2007 03:30:00 7.1 0.5 9.1 5.7 7.7 0.5 9.5 6.1 7.7 0.6 9.5 5.7 108 0 108 165 0.8 0 0.9 0.7 04/15/2007 03:40:00 7.1 0.5 8.4 5.7 7.6 0.5 8.8 6.1 7.7 0.6 9.1 6.1 108 0 108 165 0.8 0 0.9 0.7 04/15/2007 03:50:00 6.8 0.4 8 5.7 7.2 0.4 8.4 6.1 7.2 0.5 8.8 5.7 108 0 108 165 0.8 0 0.9 0.7 04/15/2007 04:00:00 6.5 0.5 7.6 5.3 7 0.4 8 6.1 7 0.5 8.4 5.7 108 0 108 165 0.8 0 0.9 0.7 04/15/2007 04:10:00 6.4 0.4 7.6 5.7 6.9 0.4 8 5.7 7 0.5 8.4 5.3 108 0 108 165 0.8 0 0.9 0.7 04/15/2007 04:20:00 6 0.5 7.6 4.9 6.4 0.4 7.6 5.3 6.5 0.6 8 4.9 108 0 108 165 0.8 0 0.9 0.7 04/15/2007 04:30:00 6.1 0.5 7.2 4.2 6.5 0.5 7.6 4.9 6.5 0.7 8.4 4.2 108 0 108 165 0.8 0 1.1 0.9 04/15/2007 04:40:00 6.3 0.7 8 3.8 6.6 0.7 8 4.2 6.7 0.8 8.4 4.2 108 0 108 165 0.9 0 1.1 0.9 04/15/2007 04:50:00 7.3 0.5 8.8 5.7 7.5 0.5 9.1 6.1 7.6 0.7 9.5 5.7 108 0 108 165 0.9 0 1.1 0.9 04/15/2007 05:00:00 6.7 0.6 8.4 5.3 6.9 0.6 8.8 5.7 7 0.8 8.8 4.9 108 0 108 165 1 0 1.4 0.9 04/15/2007 05:10:00 6.7 0.5 7.6 5.3 7 0.5 8 4.9 7.1 0.6 8.4 5.3 108 0 108 165 1.1 0 1.4 0.9 04/15/2007 05:20:00 6.3 0.7 7.6 4.2 6.5 0.7 8 4.6 6.6 0.8 8.8 4.2 108 0 108 165 1.1 0 1.4 0.9 04/15/2007 05:30:00 5.9 0.6 7.2 3.4 6.2 0.6 7.6 3.8 6.3 0.7 8 4.2 108 0 108 165 1.1 0 1.4 0.9 04/15/2007 05:40:00 5.6 0.5 6.5 3.8 5.9 0.5 7.2 4.2 6.1 0.6 7.6 4.6 108 0 108 165 1.1 0 1.4 0.9 04/15/2007 05:50:00 5.4 0.7 6.8 3.4 5.6 0.7 7.2 3.8 5.9 0.8 7.6 3.8 108 0 108 165 1.1 0 1.4 0.9 04/15/2007 06:00:00 4.9 0.5 6.1 3.4 5 0.5 6.1 3.8 5.2 0.5 6.5 3.8 108 0 108 165 1.1 0 1.4 0.9 04/15/2007 06:10:00 5.4 0.5 6.5 3.8 5.6 0.5 6.8 4.2 5.9 0.6 7.6 4.2 108 0 108 165 1.1 0 1.4 0.9 04/15/2007 06:20:00 5 0.5 6.1 3.4 5.2 0.5 6.1 3.4 5.4 0.6 6.5 3.8 108 0 108 165 1 0 1.4 0.9 04/15/2007 06:30:00 4.9 0.5 6.5 3 5 0.5 6.5 3.8 5.3 0.6 7.2 3.8 108 0 108 165 1 0 1.1 0.9 04/15/2007 06:40:00 5.5 0.6 6.8 3.8 5.6 0.6 7.2 3.8 5.8 0.6 7.2 3.8 108 0 108 165 1 0 1.4 0.9 04/15/2007 06:50:00 5.9 0.5 6.8 4.6 6.1 0.5 7.2 4.6 6.3 0.6 7.6 4.9 108 0 108 165 1.1 0 1.4 0.9 04/15/2007 07:00:00 5.5 0.5 6.5 4.2 5.7 0.5 6.8 4.6 5.8 0.6 7.2 4.6 108 0 107 165 1.2 0 1.4 0.9 04/15/2007 07:10:00 5.3 0.5 6.5 3.8 5.5 0.5 6.5 4.2 5.7 0.5 6.8 4.2 108 0 108 165 1.2 0 1.4 0.9 04/15/2007 07:20:00 5 0.5 6.1 3.8 5.2 0.5 6.1 3.8 5.4 0.5 6.5 4.2 108 0 108 165 1.2 0 1.4 0.9 04/15/2007 07:30:00 5.5 0.6 6.5 3.8 5.6 0.6 6.8 4.2 5.8 0.5 6.8 4.2 108 0 108 165 1.2 0 1.4 1.1 04/15/2007 07:40:00 5 0.6 6.1 3 5.1 0.5 6.5 3.4 5.3 0.6 6.5 3.8 108 0 108 165 1.2 0 1.4 1.1 04/15/2007 07:50:00 4.9 0.6 6.1 3.4 4.9 0.5 6.1 3.4 5.3 0.5 6.5 3.4 108 0 108 165 1.2 0 1.4 1.1 04/15/2007 08:00:00 4.5 0.5 5.7 3 4.4 0.5 5.3 3 5 0.5 6.1 3.4 108 0 108 165 1.3 0 1.4 1.1 04/15/2007 08:10:00 4.7 0.5 5.7 3 4.5 0.5 5.3 3 5 0.6 6.1 3.4 108 0 108 165 1.3 0 1.4 1.4 04/15/2007 08:20:00 4.7 0.4 5.7 3.4 4.4 0.5 5.3 3 4.9 0.5 6.1 3.4 108 0 108 165 1.4 0 1.6 1.4 04/15/2007 08:30:00 5 0.5 6.1 3.4 4.8 0.5 5.7 3.4 5.3 0.5 6.5 3.8 108 0 108 165 1.4 0 1.6 1.4 04/15/2007 08:40:00 4.2 0.5 5.3 2.6 3.9 0.5 4.9 2.6 4.5 0.6 5.7 3 108 0 107 165 1.4 0 1.6 1.4 04/15/2007 08:50:00 4.3 0.5 5.3 2.6 4.1 0.5 4.9 2.6 4.6 0.5 6.1 3.4 108 0 108 165 1.4 0 1.6 1.4 04/15/2007 09:00:00 3.5 0.6 4.9 1.9 3.3 0.5 4.6 2.3 4 0.5 5.3 2.6 108 0 111 165 1.4 0 1.6 1.4 04/15/2007 09:10:00 2.9 0.6 4.6 1.1 2.9 0.4 4.2 1.1 3.6 0.5 4.9 2.3 108 0 108 165 1.4 0 1.6 1.4 04/15/2007 09:20:00 4 1 6.1 1.9 3.4 0.9 5.3 1.9 4.4 0.7 6.1 3 108 0 108 165 1.5 0 1.6 1.4 04/15/2007 09:30:00 4.8 0.4 5.7 3.8 4.5 0.6 5.7 2.6 5.1 0.4 6.1 3.8 98 10 107 165 1.5 0 1.6 1.4 04/15/2007 09:40:00 4.4 0.6 5.7 2.6 4.9 0.5 5.7 3.4 4.8 0.6 6.1 3.4 89 4 91 165 1.5 0 1.6 1.4 04/15/2007 09:50:00 4.4 0.6 5.7 2.6 4.9 0.5 6.1 3.4 4.9 0.6 6.1 3.4 87 5 88 165 1.5 0 1.6 1.4 04/15/2007 10:00:00 3.7 0.5 4.9 2.6 4.4 0.4 5.3 3 4.7 0.5 6.1 3.4 89 6 89 165 1.5 0 1.6 1.4 04/15/2007 10:10:00 4.1 0.5 5.7 2.6 4.6 0.4 5.7 3.4 5 0.5 6.5 3.4 86 5 90 165 1.6 0 1.6 1.4 04/15/2007 10:20:00 3.7 0.5 5.3 2.3 4.3 0.5 5.7 3 4.6 0.5 6.5 3 83 5 90 165 1.6 0 1.6 1.4 04/15/2007 10:30:00 2.9 0.7 4.9 1.9 3.6 0.5 4.9 2.6 3.9 0.5 5.3 2.6 79 7 78 165 1.6 0 1.8 1.4 04/15/2007 10:40:00 4 0.6 4.9 2.6 4.4 0.6 5.7 3 4.6 0.6 5.7 3 84 5 99 165 1.7 0 1.8 1.6 04/15/2007 10:50:00 3.5 0.6 4.9 2.3 3.9 0.5 4.9 3 4.4 0.5 5.3 3 84 5 87 165 1.7 0 1.8 1.6 04/15/2007 11:00:00 3.6 0.5 5.3 2.6 4.1 0.4 5.3 3 4.4 0.5 5.7 3.4 85 6 87 165 1.8 0 1.8 1.6 04/15/2007 11:10:00 3.1 0.5 4.2 1.9 3.6 0.5 4.9 2.3 4.1 0.4 4.9 3 83 8 92 165 1.8 0 1.8 1.6 04/15/2007 11:20:00 3.2 0.6 4.6 1.9 3.6 0.5 4.9 2.3 4.1 0.5 5.3 2.6 81 7 92 165 1.9 0 2.1 1.8 04/15/2007 11:30:00 3.1 0.5 4.9 1.9 3.2 0.6 4.6 1.9 3.7 0.6 5.7 2.6 68 8 78 165 1.9 0 2.1 1.8 04/15/2007 11:40:00 5 1.3 7.2 1.5 3.2 0.4 4.2 1.9 4.7 1.3 7.2 2.6 71 8 66 165 1.9 0 2.1 1.8 04/15/2007 11:50:00 5.4 1 8 3.4 3.1 0.5 4.2 1.9 5.5 1 7.6 3 60 9 58 165 1.9 0 2.1 1.8 04/15/2007 12:00:00 4.9 1 8.4 3 2.8 0.4 4.6 1.9 5.3 0.8 7.6 3.4 58 8 46 165 2 0 2.3 1.8 04/15/2007 12:10:00 5.6 0.7 7.6 3.4 4.2 1.5 7.2 1.9 5.9 0.7 7.2 3.8 54 8 38 165 2 0 2.3 1.8 04/15/2007 12:20:00 4.8 0.8 7.2 2.6 5.2 0.9 8 3 5.2 0.7 6.8 3.4 70 13 82 165 2 0 2.3 1.8 04/15/2007 12:30:00 4.6 0.7 6.8 2.6 5 0.8 7.2 3 5.1 0.7 7.2 3.4 63 13 67 165 2.1 0 2.3 1.6 04/15/2007 12:40:00 4.6 1 7.2 2.3 4.8 1.1 7.2 2.3 4.9 1 7.2 2.6 59 9 64 165 2 0 2.3 1.6 04/15/2007 12:50:00 5.2 0.9 7.2 3 5.3 0.9 7.6 3 5.3 0.7 7.2 3.4 59 7 62 165 2 0 2.3 1.8 04/15/2007 13:00:00 3.9 0.9 6.5 1.9 4.1 0.9 6.5 2.3 4.2 0.9 6.1 2.3 55 13 68 165 2 0 2.6 1.8 04/15/2007 13:10:00 3.7 0.8 6.5 2.3 4 0.8 6.8 2.6 4 0.8 6.8 2.3 40 11 62 165 2.1 0 2.3 1.8 04/15/2007 13:20:00 4.1 1.3 8 2.3 4.3 1.4 8.4 1.5 4.2 1.3 8.4 2.3 41 16 62 165 2.1 0 2.3 2.1 04/15/2007 13:30:00 4.3 0.9 6.8 2.3 4.6 0.9 6.8 2.3 4.7 0.8 6.8 2.6 53 11 68 165 2 0 2.3 1.8 04/15/2007 13:40:00 4.9 1.2 7.6 2.3 5.2 1.2 8 2.3 5 1.2 7.6 2.3 47 12 46 165 2.1 0 2.3 1.8 04/15/2007 13:50:00 4.2 0.8 6.8 2.3 4.2 1 6.8 1.9 4.5 0.8 6.8 2.6 20 9 26 165 2.1 0 2.3 1.8 04/15/2007 14:00:00 5.4 1.1 7.6 2.6 5.4 1.1 7.6 2.3 5.6 0.9 7.2 3.4 25 8 18 165 2.2 0 2.3 2.1 04/15/2007 14:10:00 5.4 0.8 7.6 3.4 5.1 1 7.2 2.3 5.7 0.8 8 3.4 19 8 28 165 2.4 0.1 2.8 2.3 04/15/2007 14:20:00 6.2 0.9 8.4 3.4 6.1 1 8.4 3.4 6.4 0.8 8.8 4.2 25 9 18 165 2.6 0 2.8 2.6 04/15/2007 14:30:00 5.3 0.9 7.2 3.4 5.4 0.9 7.2 3 5.5 0.9 7.6 3.8 33 9 29 165 2.4 0 2.8 2.3 04/15/2007 14:40:00 5.6 0.7 7.2 3 5.6 0.8 7.2 3 5.8 0.8 7.2 3.8 26 8 11 165 2.4 0 2.8 2.3 04/15/2007 14:50:00 5.6 0.8 7.2 3.8 5.4 1 7.2 1.9 5.8 0.9 8 4.2 22 8 28 165 2.5 0.1 2.8 2.3 04/15/2007 15:00:00 5.7 0.6 6.8 4.2 5.3 1 6.8 2.3 6 0.6 7.2 4.2 18 6 26 165 2.6 0 2.8 2.6 04/15/2007 15:10:00 5.7 0.8 7.2 3.8 5.6 0.8 7.2 3.4 6.1 0.8 7.6 3.8 23 8 11 165 2.5 0.1 2.8 2.3 04/15/2007 15:20:00 5.5 0.7 6.8 3.4 5.3 0.9 6.8 2.3 5.7 0.7 7.6 3.8 21 6 23 165 2.4 0 2.6 2.3 04/15/2007 15:30:00 5.3 0.8 6.8 3 5 0.8 6.8 3 5.5 0.6 7.2 4.2 21 7 28 165 2.3 0 2.6 2.1 04/15/2007 15:40:00 5.9 0.5 7.2 4.2 5.8 0.6 6.8 3.4 6.2 0.5 7.2 4.6 22 5 27 165 2.2 0 2.3 1.8 04/15/2007 15:50:00 5.5 0.5 6.5 4.2 5.1 0.6 6.5 2.6 5.9 0.5 6.8 4.6 19 4 24 165 2.3 0 2.6 2.1 04/15/2007 16:00:00 5.7 0.6 7.2 4.2 5.7 0.8 7.2 3.4 5.9 0.6 7.6 4.6 24 7 27 165 2.4 0.1 2.6 1.8 04/15/2007 16:10:00 6.3 0.4 7.2 4.6 6.2 0.5 7.2 4.6 6.4 0.5 7.2 4.9 22 5 18 165 2 0 2.3 1.8 04/15/2007 16:20:00 5.8 0.4 7.2 4.6 5.2 0.7 6.8 3 6.1 0.5 7.2 4.6 16 4 21 165 2.4 0 2.6 2.3 04/15/2007 16:30:00 5.3 0.4 6.1 4.2 3.9 0.7 6.5 2.6 5.8 0.4 6.8 4.9 10 3 16 165 2.4 0 2.6 2.3 04/15/2007 16:40:00 5 0.5 6.1 3.4 3.5 0.8 5.7 1.5 5.5 0.5 6.8 4.6 6 6 15 165 2.4 0 2.6 2.3 04/15/2007 16:50:00 5 0.4 6.1 3.4 3.2 0.6 4.9 1.9 5.4 0.5 6.5 4.2 4 6 6 165 2.4 0 2.6 2.3 04/15/2007 17:00:00 4.7 0.6 6.1 3.4 3.3 0.8 5.3 1.9 5.1 0.5 6.5 4.2 5 8 7 165 2.4 0 2.8 2.3 04/15/2007 17:10:00 4.6 0.5 6.8 3.4 3.1 0.7 6.5 1.9 5 0.5 7.2 3.8 9 5 19 165 2.3 0 2.6 2.3 04/15/2007 17:20:00 5.5 0.5 6.8 4.2 3.6 0.8 6.5 1.9 5.9 0.5 7.2 4.6 3 6 16 165 2.3 0 2.6 2.1 04/15/2007 17:30:00 4.8 0.7 7.2 3.4 3.4 0.9 6.1 1.9 5.1 0.6 7.2 3.4 359 7 4 165 2.4 0 2.6 2.3 04/15/2007 17:40:00 4.9 0.5 6.1 3.8 3.4 0.9 5.7 1.5 5.4 0.5 6.5 4.6 9 5 14 165 2.3 0 2.6 2.1 04/15/2007 17:50:00 4.7 0.5 6.1 3.4 3.4 1 5.7 1.5 5.2 0.5 6.5 3.8 358 13 357 165 2.1 0 2.3 1.8 04/15/2007 18:00:00 3.9 0.6 5.3 2.6 3.6 1 5.3 1.5 4.2 0.6 5.7 2.6 347 16 332 165 2.1 0 2.3 1.8 04/15/2007 18:10:00 4.6 0.6 6.5 3.4 4.1 1 6.8 1.9 4.9 0.5 6.5 3.8 352 8 354 165 2.1 0 2.3 1.8 04/15/2007 18:20:00 4.8 0.6 6.5 3.8 3.4 0.8 5.7 1.9 5.2 0.5 6.8 4.2 356 5 354 165 2 0 2.3 1.8 04/15/2007 18:30:00 5.3 0.7 6.8 3.8 3.8 1 6.8 1.5 5.7 0.7 7.2 3.8 1 8 19 165 1.9 0 1.8 1.6 04/15/2007 18:40:00 4.7 0.6 6.5 2.6 3.8 1 6.1 1.5 4.9 0.6 6.5 3.8 353 7 4 165 1.8 0 1.8 1.6 04/15/2007 18:50:00 5.8 0.9 8.4 4.2 4.7 1.2 8.4 2.3 6.3 0.8 8.4 4.9 353 6 351 165 1.8 0 1.8 1.6 04/15/2007 19:00:00 6.5 0.6 8 4.9 5.5 1.2 8.4 3 6.8 0.6 8 5.3 351 6 347 165 1.7 0 1.8 1.4 04/15/2007 19:10:00 5.7 0.5 6.8 4.2 5 1 6.8 2.6 6.1 0.5 7.2 4.6 351 5 350 165 1.6 0 1.6 1.4 04/15/2007 19:20:00 5.4 0.6 7.2 4.2 5.3 0.9 7.6 2.6 5.7 0.5 8 4.6 348 4 350 165 1.6 0 1.6 1.6 04/15/2007 19:30:00 5.7 0.6 7.6 4.6 5.7 0.9 7.6 3 6.1 0.6 8 4.9 347 0 347 165 1.6 0 1.8 1.4 04/15/2007 19:40:00 6.4 1 9.1 4.2 6.6 1 9.5 4.6 6.3 0.9 9.1 4.2 346 0 347 165 1.6 0 1.8 1.6 04/15/2007 19:50:00 6.3 0.6 8.4 4.6 6.3 0.8 8.8 3.8 6.5 0.6 8.4 4.6 346 0 346 165 1.6 0 1.8 1.6 04/15/2007 20:00:00 5.8 0.8 8 3.4 5.6 1 7.6 3 6 0.7 7.6 4.2 346 0 347 165 1.6 0 1.8 1.6 04/15/2007 20:10:00 4.8 0.9 7.2 3 4.9 1 7.6 2.3 5.2 0.9 7.2 3.4 346 0 347 165 1.6 0 1.8 1.6 04/15/2007 20:20:00 5.9 1.3 8.8 3.4 6.1 1.4 8.8 3 6.1 1.2 9.1 3.8 345 3 346 165 1.6 0 1.8 1.4 04/15/2007 20:30:00 5.3 1.2 9.1 3 5.5 1.2 8.8 3.4 5.2 1.2 8 2.6 337 1 337 165 1.6 0 1.8 1.6 04/15/2007 20:40:00 5.2 1.2 8 2.3 5.4 1.2 8 2.6 5.4 1.2 8 3.4 336 1 336 165 1.6 0 1.8 1.4 04/15/2007 20:50:00 5.8 1.1 8 3.4 6 1.1 8 3.4 5.9 1.1 8.8 3 331 3 330 165 1.6 0 1.8 1.6 04/15/2007 21:00:00 5.9 1.2 8.4 3.4 6 1.2 8.4 3.4 5.9 1.2 8.4 3.4 335 6 338 165 1.7 0 1.8 1.6 04/15/2007 21:10:00 5.9 1.3 8.8 3.4 6.1 1.3 8.8 3.8 5.8 1.2 8.8 3 334 6 334 165 1.7 0 1.8 1.4 04/15/2007 21:20:00 6.7 1 9.1 4.6 6.8 0.9 8.8 4.6 6.7 0.9 8.8 4.2 331 4 333 165 1.7 0 1.8 1.6 04/15/2007 21:30:00 6.6 1 9.5 3.8 6.6 1 9.5 4.2 6.7 0.9 9.9 3.8 334 7 336 165 1.8 0 1.8 1.6 04/15/2007 21:40:00 6.8 0.9 9.9 3.8 7 0.9 10.3 3.4 7 0.8 9.5 4.9 335 2 339 165 1.8 0 1.8 1.6 04/15/2007 21:50:00 7.4 1 10.7 4.9 7.6 1.1 10.7 4.9 7.4 1 10.7 4.9 335 2 338 165 1.8 0 1.8 1.6 04/15/2007 22:00:00 7.6 1 10.3 4.9 7.7 1 11.1 5.3 7.7 1 10.3 4.9 335 5 340 165 1.9 0 1.8 1.6 04/15/2007 22:10:00 7.8 1.1 10.3 4.6 7.8 1.3 10.7 3.4 7.8 1.2 11.8 5.3 338 6 339 165 1.9 0 2.1 1.8 04/15/2007 22:20:00 7.1 1.1 11.1 5.3 7.3 1 11.1 4.9 7.3 1.1 11.5 5.3 330 9 340 165 2 0 2.3 1.8 04/15/2007 22:30:00 6.2 0.7 8.4 4.2 6.5 0.7 8.8 4.6 6.4 0.7 8.4 3.8 327 5 332 165 1.8 0 1.8 1.6 04/15/2007 22:40:00 5.8 0.7 8 3.8 6 0.7 8.4 4.2 5.9 0.7 7.6 4.2 332 5 338 165 1.8 0 1.8 1.6 04/15/2007 22:50:00 5.2 0.7 6.8 3 5.4 0.7 6.8 3.8 5.3 0.5 6.5 3.8 327 5 329 165 1.8 0 1.8 1.6 04/15/2007 23:00:00 6.2 0.9 8.4 3.4 6.3 0.8 8.8 3.8 5.6 0.9 8 3.4 318 2 316 165 1.7 0 1.8 1.4 04/15/2007 23:10:00 6.9 1.2 9.5 3 7.1 1.1 9.5 3.4 6.3 1 8.8 3.4 315 4 314 165 1.8 0.1 1.8 1.6 04/15/2007 23:20:00 7.8 1 10.3 5.7 7.9 1 10.7 5.7 7 1.1 9.5 4.2 315 4 311 165 1.8 0 1.8 1.6 04/15/2007 23:30:00 8.6 1 11.8 6.1 8.7 1 11.8 6.8 8 1 11.1 5.7 314 6 309 165 1.9 0 2.1 1.8 04/15/2007 23:40:00 7.7 0.8 9.9 5.3 7.8 0.7 9.9 5.7 6.9 1 9.1 4.2 312 4 313 165 1.9 0 2.1 1.8 04/15/2007 23:50:00 7 1.1 10.3 4.2 7.1 1.1 9.9 4.6 6.7 1.2 10.3 3.8 320 10 323 165 2 0 2.3 1.6 04/16/2007 00:00:00 7.4 0.9 10.7 5.3 7.6 0.8 10.3 5.3 7.5 0.8 9.5 5.7 324 6 332 165 2 0 2.3 1.8 04/16/2007 00:10:00 7.7 1.2 10.7 5.3 7.8 1.2 10.7 5.3 7.5 1.1 10.7 4.9 319 5 328 165 1.9 0 2.3 1.8 04/16/2007 00:20:00 8.5 0.8 10.7 6.5 8.6 0.8 10.7 6.8 8.3 0.8 10.3 6.1 322 7 329 165 1.9 0.1 2.3 1.6 04/16/2007 00:30:00 7.7 1.2 11.5 5.3 7.9 1.1 11.5 6.1 7.6 1.1 10.7 4.9 322 6 336 165 2.1 0 2.3 1.8 04/16/2007 00:40:00 8.9 0.9 11.8 6.8 9 0.9 11.8 7.2 8.1 1 11.8 5.3 312 7 318 165 2 0 2.3 1.8 04/16/2007 00:50:00 9 1.1 13.3 5.7 9.2 1.1 13.3 6.1 7.5 1.3 12.2 4.9 305 6 310 165 1.9 0 2.3 1.8 04/16/2007 01:00:00 10.3 1 12.6 7.2 10.4 1 13 7.2 8.6 1.5 14.5 5.7 305 9 328 165 1.8 0 2.1 1.6 04/16/2007 01:10:00 9.7 1.2 13.7 6.5 9.8 1.2 14.9 6.5 8.9 1.4 14.5 4.6 314 9 325 165 1.9 0 2.1 1.6 04/16/2007 01:20:00 9.4 0.9 11.8 6.5 9.5 1 11.8 6.5 8.9 0.9 12.2 5.7 316 8 316 165 1.9 0 1.8 1.6 04/16/2007 01:30:00 9.5 1.3 13.3 6.5 9.6 1.3 13 6.1 8.5 1.5 11.5 4.6 312 8 331 165 2.1 0 2.6 1.8 04/16/2007 01:40:00 9.1 1.2 12.6 5.7 9.2 1.1 13 6.5 8.2 1.3 11.8 4.9 313 8 310 165 2.1 0 2.6 1.8 04/16/2007 01:50:00 9.6 1.2 13 6.5 9.6 1.2 13 6.8 8.4 1.1 11.8 4.9 309 10 303 165 2.1 0 2.3 1.8 04/16/2007 02:00:00 10.8 1 13.3 8.8 10.9 1 13.3 8.8 8.4 1.2 12.2 6.1 305 5 307 165 2.3 0 2.6 2.1 04/16/2007 02:10:00 11.8 1.2 15.3 7.6 11.9 1.2 15.3 7.6 9.2 1.2 12.6 6.8 304 5 298 165 2.3 0 2.6 2.1 04/16/2007 02:20:00 12.3 1.1 14.9 9.1 12.3 1.1 14.9 9.5 10 1.1 13.7 7.2 306 6 300 165 2.1 0 2.3 1.8 04/16/2007 02:30:00 12.9 1.1 17.2 9.5 13 1.1 17.6 10.3 10.7 1.6 15.3 7.6 307 8 310 165 2.2 0 2.6 1.8 04/16/2007 02:40:00 15 1.7 18.7 10.3 15.1 1.7 18.3 10.3 12.2 1.7 17.2 8.4 306 5 307 165 2.2 0 2.3 1.8 04/16/2007 02:50:00 16.2 1.3 19.1 12.6 16.3 1.3 19.1 13 13.1 1.5 16.8 8.4 306 4 306 165 2.2 0 2.3 2.1 04/16/2007 03:00:00 16.3 1.2 18.7 12.2 16.4 1.2 18.7 12.2 12.9 1.5 16.8 8.8 305 4 301 165 2.1 0 2.3 1.8 04/16/2007 03:10:00 15.4 1.1 19.1 12.2 15.4 1.1 18.7 11.8 13.4 1.6 17.2 9.1 308 5 300 165 2.1 0 2.3 1.8 04/16/2007 03:20:00 15.6 1.6 19.5 10.3 15.6 1.7 19.5 10.3 13.4 1.6 17.2 8.8 308 5 305 165 2.2 0 2.3 1.8 04/16/2007 03:30:00 16.5 1.3 19.5 13.3 16.5 1.4 19.5 13 14.6 1.6 17.9 10.3 309 5 301 165 2.1 0 2.3 1.8 04/16/2007 03:40:00 17.7 1 20.6 14.9 17.7 1 20.6 14.9 15.8 1.3 19.5 11.5 309 3 311 165 2.1 0 2.3 1.8 04/16/2007 03:50:00 17.4 1.2 19.9 14.5 17.3 1.2 20.2 14.1 15.7 1.5 19.5 11.5 310 4 307 165 2.1 0 2.3 1.8 04/16/2007 04:00:00 17 1.2 19.9 13.3 16.8 1.2 19.9 13.3 16 1.4 18.7 10.7 311 5 308 165 2.2 0 2.3 1.8 04/16/2007 04:10:00 17.5 1 19.9 14.5 17.3 1 19.9 14.5 15.8 1.3 18.7 11.8 311 4 311 165 2.1 0 2.3 2.1 04/16/2007 04:20:00 18 1 20.2 14.9 17.8 1 19.9 14.9 16.4 1.3 20.2 12.2 311 4 315 165 2.2 0 2.3 1.8 04/16/2007 04:30:00 17.2 0.9 19.1 14.1 17 1 19.1 14.1 16.2 1.2 18.7 12.2 311 4 310 165 2.3 0 2.6 2.1 04/16/2007 04:40:00 16.5 0.9 18.7 14.1 16.4 0.9 18.3 13.3 15.2 1.2 19.1 11.8 310 4 306 165 2.4 0 2.6 2.3 04/16/2007 04:50:00 16 1 19.1 13 15.9 1.1 18.7 13.3 14.4 1.4 17.9 9.9 309 4 307 165 2.4 0 2.6 2.3 04/16/2007 05:00:00 17 0.8 19.1 14.5 16.8 0.8 18.7 14.5 16 1.2 18.7 11.5 311 3 305 165 2.4 0 2.6 2.3 04/16/2007 05:10:00 16.1 1.2 18.7 13 16 1.2 18.7 12.2 15.3 1.3 17.9 11.8 312 4 312 165 2.4 0 2.6 2.3 04/16/2007 05:20:00 17 1.2 19.5 13.7 16.8 1.2 19.1 13.7 16.1 1.5 19.5 11.5 312 4 320 165 2.4 0 2.8 2.3 04/16/2007 05:30:00 17.7 0.8 20.2 15.3 17.6 0.8 19.9 14.9 17 1 19.5 13.3 312 3 314 165 2.6 0 2.8 2.3 04/16/2007 05:40:00 18.1 1.1 21.4 14.9 17.9 1.2 21.4 14.5 17.7 1.5 21.8 12.6 313 3 314 165 2.6 0 2.8 2.3 04/16/2007 05:50:00 17.6 1.1 19.9 14.9 17.4 1.2 20.2 14.5 17.1 1.3 20.6 11.8 312 4 314 165 2.7 0 2.8 2.6 04/16/2007 06:00:00 17.4 1.2 20.2 13.3 17.3 1.2 20.2 13 17 1.4 20.2 12.6 312 5 306 165 2.6 0 2.8 2.6 04/16/2007 06:10:00 17.5 1.1 21 14.9 17.3 1.1 21 14.9 16.6 1.7 20.2 11.1 312 5 315 165 2.6 0 2.8 2.6 04/16/2007 06:20:00 17 1.1 19.9 14.1 16.9 1.1 19.9 13.7 16 1.7 19.1 10.7 310 5 309 165 2.7 0 2.8 2.6 04/16/2007 06:30:00 17.7 1.1 20.2 14.5 17.5 1.1 20.2 14.1 16.9 1.5 20.2 12.2 312 4 312 165 2.8 0 3 2.6 04/16/2007 06:40:00 17.1 1.2 19.9 14.1 17 1.2 19.5 13.3 15.1 1.7 19.5 11.1 309 5 310 165 2.9 0 3 2.8 04/16/2007 06:50:00 16.4 1.3 19.5 13 16.3 1.3 19.9 12.6 13.7 1.5 17.9 10.3 308 5 304 165 2.9 0 3.3 2.8 04/16/2007 07:00:00 15.8 1.1 18.3 13 15.6 1.1 18.3 13 14 1.5 17.2 9.9 309 5 312 165 3 0 3.3 2.8 04/16/2007 07:10:00 15.8 1.2 18.7 12.2 15.6 1.2 18.7 12.6 14.1 1.4 17.6 10.7 310 4 304 165 3.2 0 3.3 3 04/16/2007 07:20:00 14.6 1.1 17.2 11.8 14.4 1.1 17.2 11.5 14.1 1.2 16.4 10.7 314 5 316 165 3.1 0 3.3 3 04/16/2007 07:30:00 14.9 1.2 17.9 11.8 14.7 1.2 17.9 11.1 14.6 1.5 17.9 10.3 316 6 313 165 3.2 0 3.5 3 04/16/2007 07:40:00 16.7 1.5 19.5 11.8 16.5 1.5 19.5 11.8 16.2 1.7 19.5 11.1 315 5 312 165 3.5 0 3.5 3.3 04/16/2007 07:50:00 17.4 1.3 20.2 13.7 17.2 1.3 20.2 13.3 16 1.6 20.2 11.5 310 4 308 165 3.5 0 3.5 3.3 04/16/2007 08:00:00 17 1.2 19.5 13.3 16.8 1.1 19.5 13.3 16.5 1.5 19.5 11.1 312 5 313 165 3.5 0 3.5 3.3 04/16/2007 08:10:00 17.2 1.2 20.2 13.7 17 1.2 20.2 13.3 16.5 1.3 19.5 13 312 5 312 165 3.3 0 3.5 3.3 04/16/2007 08:20:00 17.4 1.1 20.2 13.7 17.2 1.1 19.9 13.7 16.2 1.9 20.2 10.3 311 5 315 165 3.3 0 3.5 3.3 04/16/2007 08:30:00 16.3 1.2 19.1 13.3 16.1 1.2 19.1 13 14.9 2.2 19.9 8.8 309 6 310 165 3.2 0 3.5 3 04/16/2007 08:40:00 16.5 1.3 19.5 13 16.4 1.3 19.1 13 14.1 2.3 19.9 9.5 307 6 325 165 3.5 0 3.8 3.3 04/16/2007 08:50:00 16.3 1.5 19.5 11.8 16.2 1.5 19.5 12.2 13.3 1.9 17.9 9.9 306 5 307 165 3.3 0 3.5 3 04/16/2007 09:00:00 17.4 1.5 20.6 12.2 17.3 1.5 20.6 12.6 14 2.1 20.2 9.5 305 5 312 165 3.5 0.2 3.8 3 04/16/2007 09:10:00 15.8 1.7 19.9 11.1 15.7 1.7 19.9 10.7 12.2 1.7 17.6 8 304 6 301 165 3.3 0 3.5 3.3 04/16/2007 09:20:00 14.2 1.4 17.2 11.1 14.1 1.4 17.2 10.7 10.6 1.4 16.4 7.6 302 6 303 165 3.3 0 3.5 3.3 04/16/2007 09:30:00 14.1 1.6 17.2 10.3 14 1.6 17.2 10.3 11.3 1.9 16.4 6.8 297 7 297 165 3.5 0 3.5 3.3 04/16/2007 09:40:00 13.1 1.3 16.1 9.9 13 1.4 16.1 9.5 10.9 1.7 15.6 7.2 300 9 286 165 3.5 0 3.5 3.3 04/16/2007 09:50:00 13.7 1 16.1 10.7 13.6 1.1 15.6 10.7 10.9 1.5 15.6 7.6 306 5 314 165 3.5 0 3.8 3.3 04/16/2007 10:00:00 14.9 0.9 17.2 11.8 14.8 0.9 17.6 11.5 10.9 1.1 13.7 8.4 304 3 305 165 3.7 0 4 3.5 04/16/2007 10:10:00 14.1 1.2 16.8 10.3 14.1 1.3 16.8 10.3 11.3 1.4 14.9 8 305 5 304 165 4 0.2 4.3 3.5 04/16/2007 10:20:00 13.5 1.2 17.2 10.3 13.4 1.2 17.6 10.3 10.3 1.4 15.6 7.6 301 6 301 165 4.1 0.1 4.3 3.5 04/16/2007 10:30:00 13.9 1.4 16.8 10.3 13.9 1.5 16.8 10.3 10.7 1.3 14.5 8 301 6 297 165 3.9 0.1 4.3 3.5 04/16/2007 10:40:00 12.3 1 15.3 10.3 12.2 1 14.9 9.1 10.2 1.5 14.1 6.8 299 8 309 165 3.5 0.2 4 2.8 04/16/2007 10:50:00 13.9 1.2 17.2 11.5 13.8 1.2 17.2 11.5 10.6 1.5 15.3 7.6 297 6 295 165 3.6 0.1 3.8 3 04/16/2007 11:00:00 14.4 1 16.4 10.7 14.4 1 16.8 10.3 11.7 1.5 15.6 8.4 304 6 300 165 3.7 0 4 3.5 04/16/2007 11:10:00 14.4 1.3 17.2 11.5 14.3 1.3 17.2 11.1 11.7 1.5 15.6 8.4 305 5 303 165 3.8 0 4 3.5 04/16/2007 11:20:00 14 1 16.1 10.7 13.9 1 16.4 9.9 11.1 1.7 15.6 7.6 303 6 301 165 3.8 0 4 3.3 04/16/2007 11:30:00 13 1 16.1 10.3 12.9 1 15.6 10.3 10.7 1.4 14.9 7.6 300 8 312 165 4 0.3 4.8 3.3 04/16/2007 11:40:00 13.4 1 15.6 10.7 13.5 1.1 15.6 10.3 11.6 1.7 16.1 7.2 294 7 282 165 3.9 0.2 4.5 3.3 04/16/2007 11:50:00 14.3 0.9 16.4 11.5 14.3 0.9 16.4 11.5 10.4 1.1 13 8 302 4 307 165 3.8 0 4 3.5 04/16/2007 12:00:00 14 1.2 17.2 11.1 13.9 1.2 17.2 11.1 10.8 1.4 14.9 8 303 5 300 165 3.8 0.1 4.3 3.5 04/16/2007 12:10:00 14.6 1 16.8 11.8 14.5 1 17.2 11.8 12.5 1.7 16.8 8.4 307 4 312 165 4.2 0.1 4.5 3.8 04/16/2007 12:20:00 14.5 1 16.8 12.2 14.4 1 17.2 11.8 12.7 1.3 15.6 9.1 309 4 304 165 4.5 0.2 5 4 04/16/2007 12:30:00 14.9 1.2 18.3 11.5 14.9 1.2 18.3 11.5 11.6 1.3 15.6 8.4 305 4 301 165 4.4 0.2 5 3.8 04/16/2007 12:40:00 15.5 0.8 17.2 11.5 15.5 0.8 16.8 11.8 11.1 1.1 14.1 8 303 3 302 165 4.4 0 4.8 4.3 04/16/2007 12:50:00 14.8 1 17.6 12.2 14.7 1 17.6 11.8 11.7 1.5 15.6 8.4 305 5 301 165 4.4 0.1 4.8 3.8 04/16/2007 13:00:00 15.1 1 17.6 11.8 15 1 17.6 11.8 12 1.7 16.1 8.4 305 4 310 165 4.4 0.2 4.8 4.3 04/16/2007 13:10:00 15.1 1.3 17.9 11.8 15 1.4 17.9 11.8 12.4 1.7 17.2 8 305 5 307 165 4.5 0.1 4.8 4 04/16/2007 13:20:00 15.4 1.1 17.6 12.6 15.2 1.1 17.6 12.2 12.8 1.7 17.2 9.5 307 5 299 165 4.6 0.1 4.8 4.3 04/16/2007 13:30:00 14.4 1 16.8 11.8 14.2 1 16.8 11.5 12.7 1.2 15.6 9.9 310 5 303 165 4.8 0 5 4.5 04/16/2007 13:40:00 13.7 1.2 15.6 9.9 13.5 1.2 15.6 9.5 11.8 1.2 16.8 8.8 308 6 306 165 4.8 0 5.2 4.5 04/16/2007 13:50:00 13.5 1.4 16.4 9.5 13.4 1.4 16.1 9.5 11.1 1.4 14.1 6.5 306 5 310 165 4.8 0.2 5.2 4.5 04/16/2007 14:00:00 12 1.3 14.9 8.4 11.9 1.3 14.9 8 9.1 1.1 12.6 6.1 304 6 296 165 4.8 0.1 5.2 4.5 04/16/2007 14:10:00 11.5 1.1 14.5 9.1 11.3 1.1 14.1 8.4 8.9 1.2 12.2 6.1 303 6 297 165 5.1 0 5.5 4.8 04/16/2007 14:20:00 10.4 1.1 13.7 8 10.2 1.1 13.3 7.6 8.1 1 11.5 6.1 301 7 305 165 4.9 0 5 4.8 04/16/2007 14:30:00 10.1 1.7 13.3 4.9 10 1.7 13.3 5.3 7.6 1.1 11.1 3.8 299 7 300 165 4.8 0 5 4.5 04/16/2007 14:40:00 9.5 1.3 12.6 6.1 9.5 1.3 12.2 6.5 7.5 1.1 10.7 4.6 297 8 301 165 4.6 0 5 4.5 04/16/2007 14:50:00 9.2 1 11.5 5.7 9.2 1 11.5 6.1 7.7 1.2 10.7 4.2 292 7 302 165 4.7 0 5 4.5 04/16/2007 15:00:00 8.4 1 11.1 5.7 8.4 1 10.7 6.1 7.4 1.1 11.1 4.2 290 9 289 165 4.6 0.1 5 4.3 04/16/2007 15:10:00 9 1.3 11.8 6.1 9 1.3 11.8 5.7 8.5 1.6 11.8 4.9 288 7 286 165 4.2 0 4.5 4 04/16/2007 15:20:00 9.6 1.1 12.6 6.5 9.6 1.1 12.6 6.5 8.9 1.6 11.8 4.6 289 7 271 165 4.1 0.1 4.5 3.5 04/16/2007 15:30:00 8.6 1.2 13.3 5.7 8.7 1.2 13.7 6.1 8.2 1.5 13.3 4.9 286 8 290 165 4.4 0.1 4.8 3.8 04/16/2007 15:40:00 9.8 0.8 11.8 7.6 9.9 0.8 11.8 8 9.4 1 12.2 6.1 287 4 285 165 4.3 0 4.8 3.8 04/16/2007 15:50:00 10.2 1 13 6.1 10.2 1 13 6.1 9.2 1.4 12.2 4.6 289 4 290 165 4.4 0 4.5 3.8 04/16/2007 16:00:00 9.3 0.9 11.5 6.5 9.4 1 11.5 6.5 8 1.7 11.8 4.6 291 8 284 165 4.4 0 4.8 4.3 04/16/2007 16:10:00 9.7 0.7 11.5 7.6 9.7 0.7 11.5 6.8 7.2 0.9 10.3 4.6 302 4 300 165 4.6 0.1 5 4.3 04/16/2007 16:20:00 9.7 0.8 11.1 7.2 9.6 0.8 11.1 7.6 8.3 1.1 10.7 6.1 308 6 301 165 4.8 0.1 5 4.3 04/16/2007 16:30:00 10.3 0.7 11.8 7.2 10.1 0.6 11.5 7.2 9.8 0.9 11.8 6.8 313 4 309 165 4.6 0.4 5.2 3.8 04/16/2007 16:40:00 8.6 1.2 11.1 5.7 8.5 1.2 10.7 6.1 7.5 1.3 10.7 4.2 309 6 309 165 4.1 0.1 4.8 3.5 04/16/2007 16:50:00 8.3 1.1 10.3 4.6 8.4 1.1 10.3 4.9 6.4 0.9 9.1 4.2 300 7 298 165 4.7 0.1 5.2 4.3 04/16/2007 17:00:00 8.4 0.7 10.3 6.5 8.5 0.7 10.3 6.1 6.9 0.8 8.8 4.9 304 5 297 165 4.6 0.1 5 4.3 04/16/2007 17:10:00 7.6 0.7 9.5 4.9 7.6 0.7 9.5 5.7 6.2 0.8 8.4 4.6 304 7 299 165 4.8 0 5 4.5 04/16/2007 17:20:00 8.7 0.6 10.3 7.2 8.7 0.6 10.3 7.2 6.5 0.8 9.5 4.9 299 5 290 165 4.4 0.1 5 3.8 04/16/2007 17:30:00 8.8 0.6 10.3 6.8 8.8 0.6 10.3 6.8 6.7 0.8 8.8 5.3 301 5 301 165 4.2 0 4.5 3.5 04/16/2007 17:40:00 9.3 0.9 11.5 6.5 9.3 1 11.1 6.5 7 1 10.3 4.6 300 6 302 165 4.1 0 4.5 3.8 04/16/2007 17:50:00 8.8 0.8 11.1 6.8 8.7 0.9 11.1 6.8 7 0.9 9.5 4.9 304 5 307 165 4.3 0 4.5 4.3 04/16/2007 18:00:00 7.9 0.8 9.9 6.5 8 0.8 9.9 6.5 6.3 0.9 8.8 4.2 298 6 302 165 4.3 0 4.5 4.3 04/16/2007 18:10:00 8.3 0.6 9.9 6.5 8.3 0.6 9.9 6.5 7 0.9 9.1 4.9 293 6 286 165 4.1 0.1 4.5 3.8 04/16/2007 18:20:00 8.2 0.9 10.3 5.3 8.2 0.9 10.3 4.9 6.2 0.9 9.1 4.2 299 5 298 165 4.1 0.1 4.5 3.5 04/16/2007 18:30:00 8.4 0.7 9.9 6.5 8.4 0.7 10.3 6.5 6.9 1 9.5 4.6 294 5 296 165 4 0 4.3 3.8 04/16/2007 18:40:00 8.2 1 10.7 6.5 8.3 1 11.1 6.1 6.4 0.9 9.1 4.6 301 5 298 165 3.8 0.1 4.3 3.3 04/16/2007 18:50:00 8.7 0.8 10.7 6.8 8.8 0.8 10.7 6.8 7 1 10.3 4.9 298 6 298 165 3.8 0 4 3.3 04/16/2007 19:00:00 8.5 1.1 10.7 5.7 8.6 1.1 10.7 5.3 6.6 1 9.5 4.2 298 6 296 165 3.6 0 3.8 3.3 04/16/2007 19:10:00 7.9 0.9 9.9 5.7 7.9 0.9 10.3 5.3 6.3 1 9.9 3.8 295 5 298 165 3.6 0.1 3.8 3.3 04/16/2007 19:20:00 6.6 0.7 8.8 4.6 6.7 0.8 8.8 4.6 5.8 1 8.4 3.4 289 5 292 165 3.6 0.1 3.8 3 04/16/2007 19:30:00 7.2 0.7 8.8 4.9 7.3 0.7 8.8 5.3 6.7 1 8.4 4.2 287 5 292 165 3.6 0 3.8 3.5 04/16/2007 19:40:00 6.7 0.6 8 5.3 6.8 0.6 8.4 5.3 6.3 0.8 8 3.8 288 5 292 165 3.4 0 3.8 3.3 04/16/2007 19:50:00 6.2 0.6 7.6 4.2 6.4 0.6 7.6 4.6 6 0.6 7.6 3.8 279 5 275 165 3.3 0 3.5 3.3 04/16/2007 20:00:00 5.2 0.7 7.2 3 5.3 0.7 7.2 3.4 4.8 0.8 6.8 3 281 6 275 165 3.2 0 3.5 3 04/16/2007 20:10:00 5.3 0.6 6.5 3.4 5.5 0.6 6.8 3.8 5.2 0.7 6.8 3 280 5 288 165 3.1 0.1 3.3 2.8 04/16/2007 20:20:00 5 0.7 6.8 3.4 5.1 0.6 6.8 3.8 4.8 0.6 6.5 3 278 6 275 165 3 0 3.3 2.8 04/16/2007 20:30:00 4.5 0.6 5.7 3 4.6 0.6 5.7 3 4.2 0.8 5.7 2.3 283 8 283 165 3.1 0 3.3 2.8 04/16/2007 20:40:00 4 0.5 5.3 2.6 4.3 0.5 5.3 2.6 4.4 0.4 5.7 3.4 270 8 277 165 3 0 3.3 2.8 04/16/2007 20:50:00 2.5 0.9 4.9 0.4 2.8 1 5.3 0.4 3.1 0.9 5.3 1.5 259 24 250 165 3 0 3.3 2.8 04/16/2007 21:00:00 1.7 0.6 3 0.4 1.7 0.6 3 0.4 1.9 0.6 3.4 0.4 244 35 277 165 3 0 3.5 2.8 04/16/2007 21:10:00 2.7 0.6 4.2 0.7 2.7 0.6 4.2 0.7 2.8 0.5 4.6 1.5 204 15 193 165 3.6 0.1 3.8 3.3 04/16/2007 21:20:00 1.8 0.5 3.4 0.7 1.7 0.5 3.4 0.7 1.9 0.5 3.4 0.4 206 21 193 165 3.5 0 3.8 3.3 04/16/2007 21:30:00 3 0.6 4.6 1.9 2.9 0.6 4.6 1.9 3.2 0.5 4.6 1.9 173 8 164 165 3.6 0.1 3.8 3.3 04/16/2007 21:40:00 4.4 0.6 6.1 3.4 4.3 0.5 5.7 3.4 4.6 0.5 6.1 3 174 8 183 165 3.5 0 3.8 3 04/16/2007 21:50:00 4.1 0.5 5.3 3 3.9 0.5 4.9 2.6 4.1 0.5 5.3 2.6 177 5 175 165 3.3 0 3.5 3.3 04/16/2007 22:00:00 4.3 0.6 6.1 3 4.1 0.6 5.7 3 4.4 0.6 5.7 3.4 182 8 175 165 3 0.1 3.3 2.8 04/16/2007 22:10:00 3.7 0.4 4.9 2.6 3.6 0.4 4.6 2.6 3.9 0.4 4.6 3 181 7 182 165 2.9 0 3 2.8 04/16/2007 22:20:00 4.2 0.3 4.9 3.4 4 0.3 4.6 3.4 4.5 0.3 5.3 3.8 175 5 166 165 2.6 0 2.8 2.6 04/16/2007 22:30:00 5 0.4 6.1 4.2 4.8 0.4 5.7 3.8 5.2 0.4 6.1 4.2 172 7 180 165 2.4 0 2.8 2.3 04/16/2007 22:40:00 4.4 0.5 5.7 3 4.3 0.4 5.3 3 4.6 0.4 5.7 3.8 162 6 160 165 2.1 0.2 2.6 1.8 04/16/2007 22:50:00 4.7 0.6 6.1 3.4 4.7 0.5 6.1 3.4 4.8 0.5 6.1 3.4 160 6 165 165 1.9 0 2.3 1.8 04/16/2007 23:00:00 4.4 0.4 5.3 3.4 4.4 0.4 5.3 3.4 4.5 0.4 5.7 3.4 156 4 157 165 1.8 0 2.1 1.6 04/16/2007 23:10:00 4.8 0.8 6.5 3 4.7 0.7 6.5 3.4 4.7 0.6 6.5 3.4 161 9 153 165 1.8 0 1.8 1.6 04/16/2007 23:20:00 5.5 0.8 6.8 3.4 5.4 0.8 6.8 3.8 5.5 0.6 6.8 3.8 165 10 166 165 1.9 0.1 2.3 1.6 04/16/2007 23:30:00 5.4 0.5 7.2 4.2 5.3 0.5 6.5 4.2 5.3 0.5 6.8 4.2 164 8 172 165 2 0.1 2.3 1.6 04/16/2007 23:40:00 4.9 0.4 6.1 3.8 4.7 0.4 6.1 3.8 4.9 0.3 6.1 4.2 158 5 157 165 1.5 0.1 1.8 1.4 04/16/2007 23:50:00 5.4 0.4 6.5 4.6 5.2 0.4 6.1 4.6 5.4 0.3 6.5 4.6 157 5 158 165 1.4 0 1.6 1.4 04/17/2007 00:00:00 6 0.6 7.6 4.9 5.8 0.6 7.6 4.9 6 0.6 7.6 4.9 157 6 154 165 1.5 0 1.8 1.4 04/17/2007 00:10:00 6.2 0.4 7.2 5.3 6 0.4 7.2 4.9 6.3 0.4 7.2 5.3 159 15 162 165 1.3 0 1.4 1.1 04/17/2007 00:20:00 6.4 0.4 7.6 4.9 6.2 0.4 7.2 4.9 6.3 0.4 7.2 4.9 156 11 155 165 1.3 0 1.6 1.1 04/17/2007 00:30:00 6.1 0.7 7.6 4.2 6.1 0.7 7.6 4.2 6.1 0.6 7.6 4.9 155 5 156 165 1.4 0 1.6 1.1 04/17/2007 00:40:00 5.8 1 7.2 3.4 5.7 0.9 7.2 3.8 5.8 0.8 7.2 4.2 152 6 158 165 1.5 0 1.8 1.4 04/17/2007 00:50:00 4.8 0.6 6.5 3 4.8 0.6 6.5 3.4 5 0.5 6.5 3 151 7 161 165 1.5 0.1 1.8 1.4 04/17/2007 01:00:00 4.2 0.4 5.3 3 4.4 0.4 6.1 3.4 4.6 0.4 6.1 3.4 151 7 155 165 1.5 0 1.6 1.4 04/17/2007 01:10:00 3.4 0.5 4.6 2.3 3.4 0.5 4.6 1.9 3.6 0.4 4.9 2.3 145 9 147 165 1.4 0.1 1.6 1.1 04/17/2007 01:20:00 3.9 0.5 5.3 2.6 4 0.4 5.3 3 4.2 0.4 5.3 3.4 143 7 140 165 1.4 0 1.6 1.1 04/17/2007 01:30:00 3.5 0.5 5.3 2.6 3.6 0.4 5.3 2.6 3.9 0.4 4.9 2.6 147 7 145 165 1.4 0 1.6 1.4 04/17/2007 01:40:00 3.6 0.4 4.6 2.3 3.7 0.4 4.9 2.6 3.9 0.4 4.9 3 150 7 147 165 1.3 0 1.6 1.4 04/17/2007 01:50:00 3.1 0.5 4.2 1.1 3.1 0.5 4.6 1.1 3.3 0.4 4.2 1.9 146 9 158 165 1.3 0 1.4 1.1 04/17/2007 02:00:00 3.7 0.3 4.6 2.3 3.5 0.3 4.2 2.3 3.4 0.3 4.2 2.6 158 3 161 165 1.5 0 1.8 1.4 04/17/2007 02:10:00 2.2 0.8 3.8 0.7 2.2 0.8 3.8 0.7 1.9 0.6 3.4 0.7 152 8 154 165 1.6 0 1.8 1.4 04/17/2007 02:20:00 2.2 0.5 3.8 0.7 2 0.6 3.4 0.7 2.1 0.4 3 1.1 162 9 183 165 1.5 0.1 1.8 1.4 04/17/2007 02:30:00 3 0.4 3.8 1.5 2.8 0.4 3.8 1.5 3 0.4 3.8 1.9 166 6 165 165 2 0.3 2.6 1.4 04/17/2007 02:40:00 3.1 0.9 4.9 1.5 3 0.8 4.9 1.5 3.2 0.6 4.9 1.9 169 8 177 165 2.3 0 2.6 2.1 04/17/2007 02:50:00 2.4 0.4 3.4 1.5 2.2 0.3 3 1.5 2.6 0.3 3 1.9 158 4 160 165 1.6 0.2 2.3 1.4 04/17/2007 03:00:00 2.3 0.3 3 1.5 1.8 0.4 2.6 0.7 2.4 0.3 3 1.5 157 5 161 165 1.2 0 1.4 0.9 04/17/2007 03:10:00 1.4 0.6 2.3 0.4 1 0.5 1.9 0.4 1.6 0.6 2.3 0.4 154 11 145 165 1.1 0 1.4 0.9 04/17/2007 03:20:00 1.2 0.8 3 0.4 1 0.7 2.6 0.4 1.2 0.8 3 0.4 156 11 139 165 1.1 0 1.4 0.9 04/17/2007 03:30:00 2.5 0.3 3 1.9 2.4 0.3 3 1.5 2.9 0.2 3.4 1.9 147 6 145 165 1 0 1.4 0.9 04/17/2007 03:40:00 2.9 0.3 3.4 2.3 2.7 0.3 3.4 1.9 3.3 0.3 3.8 2.6 157 2 160 165 0.9 0 1.1 0.9 04/17/2007 03:50:00 2.8 0.4 3.8 1.9 2.6 0.4 3.4 1.9 3.1 0.3 4.2 2.3 162 6 184 165 0.8 0 1.1 0.7 04/17/2007 04:00:00 3 0.6 4.2 1.9 2.7 0.6 3.8 1.5 3.2 0.4 3.8 2.3 168 12 190 165 0.5 0.1 0.9 0.2 04/17/2007 04:10:00 3.9 0.3 4.6 3.4 3.7 0.3 4.6 3 3.9 0.3 4.6 3.4 188 7 191 165 0.2 0 0.4 -0.1 04/17/2007 04:20:00 4.3 0.3 5.3 3.4 4.1 0.3 4.9 3.4 4.5 0.3 5.3 3.8 170 10 169 165 0.3 0 0.7 0.2 04/17/2007 04:30:00 5 1.2 8 3.4 4.8 1.1 7.2 3.4 5.1 1.1 8 3.8 163 8 168 165 0.1 0 0.4 -0.1 04/17/2007 04:40:00 7.4 0.8 9.5 5.3 7.1 0.7 9.1 4.9 7.6 0.8 9.1 5.7 166 11 180 165 0.1 0 0.2 -0.1 04/17/2007 04:50:00 6.6 0.8 8.4 4.9 6.4 0.7 8 4.6 6.7 0.7 8.4 4.9 168 13 165 165 0.1 0 0.2 -0.1 04/17/2007 05:00:00 6.4 0.6 8 4.9 6.3 0.6 8 4.9 6.6 0.7 8 5.3 187 9 199 165 0.1 0 0.2 -0.1 04/17/2007 05:10:00 7.2 0.5 8.8 6.1 6.8 0.5 8.4 5.7 7.2 0.5 8.8 6.1 180 7 179 165 0.1 0 0.2 -0.1 04/17/2007 05:20:00 7.4 0.9 9.9 5.7 7 0.8 9.5 5.3 7.4 0.8 10.3 5.7 173 8 180 165 0 0.1 0.2 -0.3 04/17/2007 05:30:00 7.5 0.7 9.5 5.7 7.2 0.6 9.1 5.3 7.7 0.7 9.5 5.7 167 8 172 165 0.1 0 0.2 -0.1 04/17/2007 05:40:00 7.8 1 10.7 6.1 7.5 0.9 9.9 5.7 8.1 1 11.1 6.1 175 6 173 165 0.1 0 0.2 -0.1 04/17/2007 05:50:00 9.4 0.8 11.1 6.5 8.8 0.7 10.3 6.1 9.6 0.8 11.5 7.2 171 11 166 165 0.2 0 0.7 -0.1 04/17/2007 06:00:00 9.4 1 12.2 6.8 8.9 0.9 11.5 6.8 9.6 1 12.2 7.2 176 11 167 165 0.5 0 0.7 0.2 04/17/2007 06:10:00 10.1 1 12.6 7.6 9.8 1.1 12.2 7.2 10.4 1.1 13.3 7.6 183 9 185 165 0.7 0.1 0.9 0.2 04/17/2007 06:20:00 10.9 1 13 8.4 10.6 1 12.6 8 11.1 1 13 8.8 181 8 181 165 0.8 0 0.9 0.4 04/17/2007 06:30:00 10.2 0.8 12.6 8 9.8 0.7 12.2 8 10.3 0.8 13 8.8 178 6 174 165 0.5 0 0.7 0.4 04/17/2007 06:40:00 9.6 0.6 11.5 8 9.2 0.6 10.7 7.6 9.7 0.7 11.8 8 174 6 177 165 0.5 0 0.7 0.2 04/17/2007 06:50:00 9.7 0.6 10.7 8.4 9.2 0.6 10.3 8 10 0.6 11.1 8.8 168 13 168 165 0.5 0 0.7 0.2 04/17/2007 07:00:00 10.1 0.4 11.1 9.5 9.7 0.3 10.7 8.8 10.4 0.4 11.5 9.1 165 8 165 165 0.4 0.1 0.7 0.2 04/17/2007 07:10:00 10.1 0.4 11.1 9.1 9.7 0.4 11.1 8.8 10.5 0.4 11.5 9.1 166 7 169 165 0.2 0 0.4 0.2 04/17/2007 07:20:00 10 0.4 11.1 8.8 9.6 0.4 10.7 8.4 10.2 0.4 11.5 8.8 167 9 166 165 0.2 0 0.2 -0.1 04/17/2007 07:30:00 11.1 0.6 12.2 9.5 10.7 0.5 11.8 9.1 11.2 0.6 13 9.9 164 14 160 165 0.2 0 0.7 -0.1 04/17/2007 07:40:00 12.5 0.6 14.5 11.1 12 0.6 13.7 10.3 12.6 0.6 14.5 11.1 167 10 168 165 0.4 0 0.7 0.2 04/17/2007 07:50:00 12.9 0.9 14.9 10.3 12.4 0.8 14.1 10.3 13.1 1 15.3 10.7 160 16 170 165 0.5 0 0.9 0.2 04/17/2007 08:00:00 12.7 0.6 14.5 10.7 12.3 0.6 14.1 10.3 13 0.6 14.1 11.1 158 23 165 165 0.7 0.1 0.9 0.4 04/17/2007 08:10:00 14 0.5 15.3 11.8 13.5 0.5 14.9 11.5 14.3 0.5 15.3 11.8 158 17 167 165 0.8 0 1.1 0.7 04/17/2007 08:20:00 14.6 0.5 16.1 13 14.2 0.5 15.6 12.6 15 0.5 16.4 13.7 160 19 166 165 0.9 0 1.1 0.7 04/17/2007 08:30:00 13.9 0.6 15.6 12.2 13.4 0.6 15.3 11.8 14.1 0.6 16.1 12.2 159 22 286 165 0.9 0 1.1 0.9 04/17/2007 08:40:00 12.7 0.5 13.7 11.1 12.3 0.5 13.3 10.7 12.9 0.6 14.1 11.1 161 18 165 165 1.1 0 1.4 0.9 04/17/2007 08:50:00 12.3 0.5 13.3 11.1 12 0.5 13 10.7 12.6 0.5 13.7 11.1 157 22 164 165 1.1 0 1.4 0.9 04/17/2007 09:00:00 11.4 0.4 12.2 9.9 11.1 0.4 11.8 9.9 11.8 0.5 12.6 9.9 157 14 165 165 1.1 0 1.4 0.9 04/17/2007 09:10:00 10.4 0.6 11.8 8.8 10.2 0.6 11.8 8.4 10.7 0.6 12.2 8.8 156 16 154 165 1.1 0 1.4 0.9 04/17/2007 09:20:00 10.6 0.5 11.5 8.8 10.5 0.5 11.5 8.8 10.9 0.6 12.2 9.1 159 8 164 165 1.2 0 1.4 1.1 04/17/2007 09:30:00 11.1 0.5 12.6 9.5 11.1 0.5 12.2 9.5 11.6 0.5 13 9.9 156 6 163 165 1.2 0 1.4 1.1 04/17/2007 09:40:00 11 0.3 11.8 10.3 10.9 0.3 11.8 9.9 11.5 0.3 12.2 10.7 156 3 155 165 1.3 0 1.4 1.1 04/17/2007 09:50:00 11.6 0.4 12.6 10.7 11.6 0.4 12.6 10.3 12.2 0.4 13 10.7 158 0 159 165 1.4 0 1.6 1.4 04/17/2007 10:00:00 12.1 0.4 13.3 11.1 12.1 0.4 13.3 11.1 12.6 0.4 13.3 11.5 158 0 159 165 1.5 0 1.6 1.4 04/17/2007 10:10:00 12 0.5 13.3 10.3 12 0.5 13.3 10.3 12.4 0.5 13.7 10.7 159 0 159 165 1.5 0 1.8 1.4 04/17/2007 10:20:00 11.9 0.6 13.3 10.3 12 0.6 13.3 9.9 12.3 0.5 13.7 11.1 159 3 160 165 1.6 0 1.8 1.6 04/17/2007 10:30:00 12 0.7 13.3 9.9 11.9 0.7 13.3 9.5 12.3 0.8 13.7 9.9 158 4 160 165 1.7 0 1.8 1.6 04/17/2007 10:40:00 11.7 1 13.7 9.1 11.3 0.9 13.3 9.1 12 1 14.1 9.5 151 11 145 165 1.7 0 1.8 1.6 04/17/2007 10:50:00 13.2 0.5 14.1 11.1 12.8 0.5 13.7 11.1 13.6 0.5 14.9 11.8 149 11 148 165 1.7 0 1.8 1.6 04/17/2007 11:00:00 11.9 0.6 13 10.3 11.5 0.6 13 9.9 12.2 0.6 13.7 10.7 151 8 165 165 1.8 0 1.8 1.6 04/17/2007 11:10:00 12.1 0.8 13.7 9.9 11.9 0.9 13.7 9.5 12.1 0.8 14.1 9.9 147 5 147 165 2 0 2.3 1.8 04/17/2007 11:20:00 13.1 0.7 14.5 11.1 13 0.7 14.5 11.1 12.9 0.8 14.9 10.7 143 3 147 165 2.1 0 2.3 1.8 04/17/2007 11:30:00 11.3 0.8 13.3 8.8 11.2 0.9 13 8.8 11.2 0.8 13.3 9.1 140 4 139 165 2.2 0 2.6 1.8 04/17/2007 11:40:00 11.2 0.8 13.3 9.1 10.9 0.9 13 8.8 11 0.9 13 8.4 144 5 145 165 2.4 0 2.6 2.3 04/17/2007 11:50:00 13 0.7 14.5 11.1 12.8 0.6 14.1 11.1 13.1 0.7 14.5 11.5 146 4 149 165 2.4 0 2.6 2.1 04/17/2007 12:00:00 13.2 1.2 15.3 10.3 13 1.2 14.9 9.9 13.2 1.3 15.6 10.3 150 5 154 165 2.4 0 2.8 2.3 04/17/2007 12:10:00 13.7 0.5 15.3 12.2 13.5 0.5 15.3 12.2 13.6 0.6 14.9 11.8 151 3 158 165 2.6 0 2.8 2.6 04/17/2007 12:20:00 14.9 0.6 17.6 13.3 14.7 0.6 17.2 13 15.1 0.6 17.2 13.3 149 10 156 165 2.7 0 2.8 2.6 04/17/2007 12:30:00 15.7 0.8 17.6 13.7 15.5 0.8 17.2 13.3 16 0.8 17.9 13.7 147 16 121 165 2.8 0 2.8 2.6 04/17/2007 12:40:00 16.5 0.6 17.9 13 16.3 0.6 17.6 13.7 16.7 0.6 18.3 14.9 146 9 145 165 2.7 0 2.8 2.6 04/17/2007 12:50:00 14.6 1 16.1 12.6 14.5 1 16.1 12.6 14.6 1.2 16.8 11.5 149 4 153 165 2.9 0 3 2.6 04/17/2007 13:00:00 13.7 0.5 15.3 11.5 13.6 0.5 14.9 11.1 13.7 0.7 15.6 11.1 148 6 133 165 2.9 0 3.3 2.8 04/17/2007 13:10:00 14.3 0.6 16.4 12.2 14.2 0.6 16.1 12.2 14.3 0.7 16.4 12.2 148 6 145 165 3 0 3.3 2.8 04/17/2007 13:20:00 14.2 0.4 15.3 13 14 0.5 15.3 12.6 14.2 0.5 15.3 11.5 150 5 135 165 3 0 3.3 2.8 04/17/2007 13:30:00 14 0.5 15.3 11.8 13.9 0.5 15.3 11.8 14.1 0.6 15.3 11.8 150 5 152 165 3 0 3.3 2.8 04/17/2007 13:40:00 14.6 0.6 16.1 13 14.4 0.5 15.6 12.6 14.7 0.6 16.4 13 150 6 148 165 3 0 3.3 2.8 04/17/2007 13:50:00 14.4 0.6 15.6 12.6 14.1 0.6 15.6 12.2 14.3 0.6 16.1 12.6 149 7 153 165 3 0 3.3 2.8 04/17/2007 14:00:00 12.5 1 15.3 10.7 12.3 1 14.9 10.3 12.7 1 15.3 10.3 148 9 151 165 3 0 3.3 2.8 04/17/2007 14:10:00 12 0.5 13.7 10.3 11.9 0.6 13.3 10.3 11.9 0.7 13.7 9.5 147 4 150 165 3 0 3.3 2.8 04/17/2007 14:20:00 10.8 0.7 13 9.5 10.7 0.7 13 9.1 10.7 0.7 12.2 9.1 146 6 147 165 2.9 0 3 2.8 04/17/2007 14:30:00 12.2 0.8 13.7 10.3 12.1 0.8 13.7 10.3 11.9 0.8 13.7 9.9 142 3 142 165 3 0 3.3 2.8 04/17/2007 14:40:00 13.3 0.5 14.5 11.1 13.2 0.5 14.1 11.5 13 0.6 14.9 11.1 142 3 140 165 3 0 3.3 2.8 04/17/2007 14:50:00 13.4 0.6 14.9 11.5 13.2 0.6 14.9 11.1 13.3 0.7 14.9 11.5 146 4 146 165 3 0 3.3 2.8 04/17/2007 15:00:00 14.3 0.8 16.1 12.2 14.1 0.8 16.1 12.2 14.3 1 16.1 11.5 148 4 149 165 3 0 3.3 2.8 04/17/2007 15:10:00 15.4 0.7 16.8 13 15.3 0.7 16.8 13 15.5 0.9 17.2 13.3 149 4 149 165 3.1 0 3.3 3 04/17/2007 15:20:00 16.6 0.8 18.3 13.3 16.4 0.8 17.9 13.3 16.9 0.8 18.7 14.1 150 4 153 165 3.1 0 3.3 2.8 04/17/2007 15:30:00 17 0.5 18.3 15.6 16.8 0.6 18.3 15.3 17.1 0.6 18.3 14.9 151 3 153 165 3.2 0 3.3 3 04/17/2007 15:40:00 17.3 0.5 18.3 15.3 17.2 0.5 18.3 15.6 17.3 0.7 18.7 14.9 149 5 150 165 3.2 0 3.3 3 04/17/2007 15:50:00 15.8 1 18.3 13.3 15.7 0.9 17.9 13 15.7 1 18.3 12.2 149 5 144 165 3.2 0 3.5 3 04/17/2007 16:00:00 15.4 0.9 17.2 13.3 15.3 0.8 17.2 13 15.3 0.9 17.9 12.6 150 3 146 165 3.2 0 3.5 3 04/17/2007 16:10:00 15 0.8 16.8 13 14.8 0.9 16.8 13 15 0.9 17.2 12.6 151 5 148 165 3.2 0 3.3 3 04/17/2007 16:20:00 15 0.5 16.4 13.7 14.8 0.6 16.4 13.3 15 0.8 16.8 13 152 4 157 165 3.2 0 3.3 3 04/17/2007 16:30:00 14.3 0.9 17.2 11.8 14.1 0.9 16.8 11.5 14.4 1 17.2 11.5 150 7 154 165 3.1 0 3.3 2.8 04/17/2007 16:40:00 13.4 0.8 15.6 11.1 13.2 0.8 15.3 10.7 13.2 0.9 15.6 10.3 150 8 160 165 3 0 3.3 2.8 04/17/2007 16:50:00 13.3 0.8 14.9 9.9 13.2 0.8 14.9 9.9 13 1 14.9 9.9 148 4 145 165 3 0 3.3 2.8 04/17/2007 17:00:00 13.5 0.7 15.3 11.5 13.5 0.7 15.3 11.5 13.3 0.8 15.3 11.1 145 5 138 165 3 0 3.3 2.8 04/17/2007 17:10:00 13.8 0.7 16.1 11.5 13.7 0.7 16.1 11.1 13.4 0.8 15.3 10.3 147 6 142 165 3 0 3.3 2.8 04/17/2007 17:20:00 13.7 0.7 15.3 11.8 13.6 0.7 15.3 11.8 13.4 0.9 14.9 10.3 147 4 154 165 3 0 3.3 2.8 04/17/2007 17:30:00 13.7 0.8 16.1 11.5 13.6 0.8 15.6 10.7 13.3 0.9 15.6 10.7 146 4 154 165 3 0 3.3 2.8 04/17/2007 17:40:00 14.7 0.9 17.2 12.6 14.6 0.9 17.2 12.6 14.3 1 17.2 11.5 145 3 148 165 3 0 3.3 2.8 04/17/2007 17:50:00 15.1 0.8 17.2 12.6 15 0.8 17.2 12.6 14.8 0.9 17.2 11.8 142 4 145 165 3 0 3.3 2.8 04/17/2007 18:00:00 16.5 1.2 20.6 14.1 16.4 1.2 20.2 13.3 16.4 1.3 21 13.3 143 6 145 165 3 0 3.3 2.8 04/17/2007 18:10:00 16.5 1 18.7 13.7 16.4 1 18.7 13.7 16.2 1 18.7 13.7 145 4 151 165 2.9 0 3 2.8 04/17/2007 18:20:00 16.5 1 19.1 13.7 16.5 1 18.7 13.7 16.3 1.1 18.7 13 145 5 151 165 2.9 0 3 2.8 04/17/2007 18:30:00 17.8 1 20.2 15.3 17.8 1 19.9 15.3 17.7 1.1 20.2 14.9 142 5 142 165 2.9 0 3 2.8 04/17/2007 18:40:00 17.4 1.1 20.2 14.5 17.3 1.1 20.2 14.5 17.3 1.1 20.2 14.5 145 4 147 165 2.7 0 3 2.6 04/17/2007 18:50:00 17.4 0.9 19.1 14.5 17.3 0.9 19.5 14.1 17.2 1 19.5 14.1 145 4 140 165 2.6 0 2.8 2.6 04/17/2007 19:00:00 17.7 0.8 19.9 15.3 17.6 0.9 19.9 15.3 17.4 1.1 19.5 14.1 145 4 145 165 2.5 0 2.6 2.3 04/17/2007 19:10:00 16.5 1.2 19.1 14.1 16.4 1.2 19.1 14.1 16.3 1.3 19.5 12.2 148 3 143 165 2.4 0 2.6 2.1 04/17/2007 19:20:00 16.5 1.3 19.9 13.3 16.5 1.3 19.9 13.7 16.2 1.5 20.2 12.6 146 4 147 165 2.5 0 2.8 2.3 04/17/2007 19:30:00 17.3 0.8 18.7 14.9 17.3 0.8 18.7 15.3 17 1 19.5 13.7 146 3 148 165 2.5 0 2.8 2.3 04/17/2007 19:40:00 19.1 0.9 21.4 16.4 19.1 0.9 21 16.1 19 1.1 21.4 16.1 147 4 146 165 2.1 0.2 2.6 1.6 04/17/2007 19:50:00 17.2 1.1 19.9 14.9 16.9 1.1 19.5 14.5 17.2 1.2 20.2 13.7 151 4 144 165 1.6 0 1.8 1.4 04/17/2007 20:00:00 14.5 1.1 16.8 11.8 14.3 1 16.8 11.8 14.2 1.2 17.2 10.7 149 0 150 165 1.5 0 1.6 1.4 04/17/2007 20:10:00 14.6 0.9 16.1 11.5 14.4 0.9 16.1 11.5 14.2 1 16.1 10.7 149 0 149 165 1.6 0 1.6 1.4 04/17/2007 20:20:00 14.3 1 16.1 11.1 14.2 0.9 16.1 11.1 14 1.1 16.4 11.1 150 0 150 165 1.6 0 1.6 1.4 04/17/2007 20:30:00 15.6 1.2 18.3 12.6 15.6 1.3 18.3 12.6 15.6 1.3 18.7 12.2 149 0 150 165 1.6 0 1.8 1.6 04/17/2007 20:40:00 16.3 1 19.1 13.7 16.4 1 19.5 14.1 16.5 1.2 19.5 13 149 0 148 165 1.7 0 1.8 1.6 04/17/2007 20:50:00 17 1 19.1 14.9 17.1 1 19.1 14.5 17.5 1.1 19.9 14.5 149 0 148 165 1.8 0 1.8 1.6 04/17/2007 21:00:00 16.4 1.1 19.5 13.7 16.3 1.1 19.1 13.3 16.4 1.2 20.2 12.6 148 0 148 165 1.9 0 2.1 1.6 04/17/2007 21:10:00 16.3 1 18.7 13.7 16.1 1 18.7 13 15.8 1 18.7 12.6 146 4 139 165 2.1 0 2.3 1.8 04/17/2007 21:20:00 16.2 1.2 19.9 13.3 16.1 1.2 19.9 13 16.4 1.2 20.6 12.6 137 8 151 165 2.4 0 2.6 2.1 04/17/2007 21:30:00 17.1 1.4 20.6 12.6 16.9 1.4 20.6 13.7 16.9 1.5 20.6 13 138 8 152 165 2.6 0 2.8 2.3 04/17/2007 21:40:00 18.5 1.9 24.4 13.7 18.3 1.9 23.7 13.7 18.3 1.7 23.3 14.1 139 7 128 165 2.7 0 2.8 2.6 04/17/2007 21:50:00 19 2.1 23.7 12.2 19 2.1 23.7 12.2 18.6 2.2 24.4 13 134 8 134 165 2.7 0 2.8 2.6 04/17/2007 22:00:00 19.7 1.7 23.3 14.5 19.7 1.6 23.3 14.1 19.5 1.7 23.3 14.1 138 7 144 165 2.7 0 2.8 2.6 04/17/2007 22:10:00 20.2 1.6 24 16.4 20.2 1.6 23.7 16.4 20 1.7 24.4 16.1 138 7 147 165 2.7 0 2.8 2.6 04/17/2007 22:20:00 21.4 2.1 26 15.3 21.3 2.1 26 15.6 21.3 2.2 25.2 15.6 137 7 125 165 2.7 0 2.8 2.6 04/17/2007 22:30:00 21 2.2 26 15.6 21 2.2 26 15.6 20.9 2.3 26.3 16.8 142 6 146 165 2.7 0 2.8 2.6 04/17/2007 22:40:00 21 1.7 25.6 16.8 21 1.7 25.6 16.4 20.9 1.9 25.6 16.8 142 7 141 165 2.7 0 2.8 2.6 04/17/2007 22:50:00 20.4 2.1 25.2 15.6 20.4 2.1 25.2 15.3 20.3 2.2 25.6 15.6 141 7 149 165 2.6 0 2.8 2.6 04/17/2007 23:00:00 20.9 1.3 24.8 16.4 20.9 1.3 24 16.4 20.9 1.5 24.4 15.3 139 7 140 165 2.6 0 2.8 2.6 04/17/2007 23:10:00 20.9 1.5 25.6 16.4 20.9 1.5 25.6 16.4 20.9 1.5 25.2 15.6 141 7 111 165 2.7 0 2.8 2.6 04/17/2007 23:20:00 20.9 1.2 24.4 17.9 20.9 1.2 24.4 17.9 20.6 1.3 24 16.8 140 7 138 165 2.7 0 2.8 2.6 04/17/2007 23:30:00 20.4 1.3 23.7 16.4 20.4 1.3 24 16.4 20 1.3 23.7 16.1 141 6 145 165 2.6 0 2.8 2.6 04/17/2007 23:40:00 20.6 1.2 24.4 17.9 20.5 1.2 24 17.6 20.3 1.5 24 15.6 144 5 141 165 2.6 0 2.8 2.3 04/17/2007 23:50:00 21.8 1.5 25.2 17.9 21.8 1.5 25.6 17.9 21.8 1.5 25.2 18.3 144 5 135 165 2.5 0 2.8 2.3 04/18/2007 00:00:00 20.7 1.5 23.7 16.1 20.6 1.5 23.7 16.1 20.5 1.7 24 15.3 144 5 145 165 2.5 0 2.8 2.3 04/18/2007 00:10:00 20.7 1.5 24.4 16.8 20.6 1.6 24.4 16.4 20.3 1.8 24.4 14.9 144 5 145 165 2.6 0 2.8 2.6 04/18/2007 00:20:00 20.1 1.5 23.7 16.8 20.1 1.5 24 16.4 19.7 1.7 23.7 15.3 144 5 150 165 2.7 0 2.8 2.6 04/18/2007 00:30:00 22.4 1.3 25.6 18.3 22.4 1.3 25.2 18.3 22.3 1.5 25.6 17.6 144 5 136 165 2.6 0 2.8 2.3 04/18/2007 00:40:00 20.6 1.7 24.4 15.6 20.5 1.7 24.8 15.3 20.4 1.9 25.2 14.5 145 4 139 165 2.5 0 2.8 2.3 04/18/2007 00:50:00 19.6 1.4 24 16.1 19.6 1.4 24.4 16.1 19.3 1.5 22.9 14.9 144 5 141 165 2.5 0 2.8 2.3 04/18/2007 01:00:00 17.5 1.3 21 14.1 17.4 1.3 21.4 14.1 17 1.3 20.2 13.7 142 6 146 165 2.7 0 2.8 2.6 04/18/2007 01:10:00 18.8 1.3 22.6 15.6 18.8 1.3 22.6 16.1 18.5 1.5 22.1 14.1 140 7 138 165 2.7 0 2.8 2.6 04/18/2007 01:20:00 19.3 1.3 22.1 15.3 19.2 1.4 22.1 15.3 18.9 1.3 22.1 15.6 140 6 139 165 2.8 0 3 2.6 04/18/2007 01:30:00 19.1 1.2 22.9 16.1 19 1.2 21.8 16.1 18.6 1.2 22.1 15.6 140 7 132 165 2.9 0 3 2.8 04/18/2007 01:40:00 19.1 1.7 23.3 13.7 19 1.7 22.9 14.1 18.7 1.9 22.6 11.8 141 6 135 165 2.9 0 3 2.6 04/18/2007 01:50:00 19.8 1.6 24 14.9 19.7 1.6 23.7 14.5 19.5 1.8 23.7 13 143 6 148 165 2.9 0 3 2.6 04/18/2007 02:00:00 19.6 1.5 23.7 14.1 19.5 1.5 23.7 14.1 19.3 1.5 23.3 15.3 144 6 136 165 2.9 0 3 2.8 04/18/2007 02:10:00 20.1 1.2 23.3 16.4 20 1.2 23.7 16.4 19.7 1.5 23.7 14.9 140 6 138 165 2.9 0 3 2.8 04/18/2007 02:20:00 19.9 1.3 22.9 17.2 19.8 1.3 22.6 17.2 19.3 1.4 22.9 15.6 140 6 145 165 2.9 0 3 2.8 04/18/2007 02:30:00 20.5 1.3 23.7 16.8 20.4 1.3 23.7 16.8 20.2 1.3 24.4 15.6 140 5 130 165 2.9 0 3 2.8 04/18/2007 02:40:00 20.8 1.5 25.2 15.6 20.7 1.5 25.2 15.6 20.4 1.7 24.4 13.3 139 6 142 165 2.8 0 3 2.6 04/18/2007 02:50:00 19.3 1.3 22.9 15.6 19.2 1.3 23.3 15.6 19 1.5 23.3 15.6 142 6 147 165 2.7 0 2.8 2.6 04/18/2007 03:00:00 20.2 1.7 23.7 14.5 20.1 1.7 24 14.9 19.7 1.8 23.7 13.3 139 7 139 165 2.7 0 2.8 2.6 04/18/2007 03:10:00 20 1.3 23.3 16.8 19.9 1.3 23.3 16.8 19.9 1.5 23.7 14.9 140 6 137 165 2.8 0 2.8 2.6 04/18/2007 03:20:00 18.9 1.2 22.6 15.6 18.8 1.2 22.1 15.6 18.8 1.3 22.9 14.9 140 5 149 165 2.8 0 3 2.6 04/18/2007 03:30:00 19.9 1.2 22.9 15.3 19.8 1.2 23.3 15.3 19.5 1.5 22.6 14.9 139 6 136 165 2.8 0 3 2.6 04/18/2007 03:40:00 19.5 1.3 23.3 16.1 19.4 1.3 23.3 16.1 19.1 1.3 23.7 14.9 138 6 131 165 2.8 0 3 2.6 04/18/2007 03:50:00 19.7 1.1 22.6 16.4 19.6 1.1 22.6 16.4 19.3 1.3 22.9 15.3 140 5 141 165 2.8 0 3 2.6 04/18/2007 04:00:00 19.3 1.3 23.7 15.6 19.2 1.3 23.7 15.6 19.1 1.3 23.3 14.9 140 6 145 165 2.8 0 3 2.6 04/18/2007 04:10:00 19.2 1.5 24 14.9 19.2 1.6 23.7 14.9 19 1.5 24 14.9 138 6 139 165 2.7 0 2.8 2.6 04/18/2007 04:20:00 18.9 1.3 22.6 13.7 18.8 1.3 22.1 13.7 18.7 1.4 21.8 13.3 140 5 139 165 2.7 0 2.8 2.6 04/18/2007 04:30:00 18.1 1.5 22.6 12.6 17.9 1.5 22.1 13.3 17.7 1.7 21.4 13 140 6 134 165 2.7 0 2.8 2.6 04/18/2007 04:40:00 18.8 1.7 22.9 14.1 18.7 1.8 22.6 14.5 18.6 1.7 22.6 13 140 5 140 165 2.7 0 2.8 2.6 04/18/2007 04:50:00 19.4 1.3 22.6 16.1 19.3 1.3 21.8 15.6 19.1 1.5 22.6 14.1 137 6 141 165 2.7 0 2.8 2.6 04/18/2007 05:00:00 18.7 1.5 22.1 14.5 18.6 1.5 21.8 14.5 18.4 1.6 21.8 13.3 138 6 133 165 2.7 0 2.8 2.6 04/18/2007 05:10:00 18 2.2 22.6 13 18 2.2 22.6 13 17.9 2.1 22.1 12.6 138 7 134 165 2.7 0 2.8 2.6 04/18/2007 05:20:00 19.9 1.6 24 15.3 19.8 1.5 23.7 15.6 19.4 1.5 23.3 16.1 139 6 132 165 2.7 0 2.8 2.6 04/18/2007 05:30:00 18.1 1.9 23.3 14.1 18 1.9 22.9 13.3 17.7 1.9 23.3 12.2 139 6 139 165 2.7 0 2.8 2.6 04/18/2007 05:40:00 17.8 1.7 22.6 13 17.7 1.7 22.1 13.3 17.5 1.8 21.4 13 139 6 140 165 2.7 0 2.8 2.6 04/18/2007 05:50:00 18.3 1.8 22.6 13 18.2 1.7 22.1 13.7 17.9 1.9 21.8 13 138 7 141 165 2.7 0 2.8 2.6 04/18/2007 06:00:00 18.5 2.1 24.4 13 18.4 2.1 24.4 12.6 18.2 2.3 24 11.5 138 7 140 165 2.6 0 2.8 2.6 04/18/2007 06:10:00 16.6 2.1 21.4 11.8 16.5 2.2 21.4 12.2 16.3 2.2 21.8 11.1 139 8 135 165 2.6 0 2.8 2.3 04/18/2007 06:20:00 17.9 1.7 22.6 13.7 17.8 1.8 22.6 13.7 17.4 2.2 22.6 11.8 138 7 135 165 2.6 0 2.8 2.6 04/18/2007 06:30:00 16.5 1.8 21 11.1 16.5 1.8 21 11.1 16.3 1.7 20.2 11.5 140 5 140 165 2.6 0 2.8 2.6 04/18/2007 06:40:00 16.4 2.2 21.4 11.5 16.3 2.2 21.4 11.1 16.1 2.2 21.4 10.3 138 8 141 165 2.7 0 2.8 2.6 04/18/2007 06:50:00 17.2 1.6 21 13 17 1.5 20.6 13 16.7 1.5 19.9 12.6 137 8 143 165 2.7 0 2.8 2.6 04/18/2007 07:00:00 16.6 1.5 20.2 11.8 16.5 1.5 20.6 12.2 16.2 1.7 20.6 11.5 138 8 132 165 2.6 0 2.8 2.6 04/18/2007 07:10:00 16.1 1.8 20.6 12.6 16.1 1.9 20.6 12.2 15.8 2 19.9 10.3 134 9 128 165 2.7 0 2.8 2.6 04/18/2007 07:20:00 17.1 1.5 22.9 13 17.1 1.5 22.6 12.2 17.1 1.5 21.4 13 135 8 136 165 2.6 0 2.8 2.6 04/18/2007 07:30:00 16.6 2 20.6 11.8 16.6 1.9 20.6 11.5 16.4 1.9 20.2 11.1 133 9 135 165 2.6 0 2.8 2.6 04/18/2007 07:40:00 15.4 1.9 20.2 9.9 15.4 1.9 19.9 9.9 15.2 1.9 19.9 9.9 135 7 135 165 2.6 0 2.8 2.6 04/18/2007 07:50:00 14.7 1.7 20.2 10.7 14.6 1.7 20.2 10.3 14.4 1.7 19.9 10.7 135 8 137 165 2.7 0 2.8 2.6 04/18/2007 08:00:00 14.3 1.7 19.9 9.9 14.3 1.6 19.9 9.9 14 1.7 19.9 10.3 137 8 130 165 2.7 0 2.8 2.6 04/18/2007 08:10:00 16 1.6 20.6 11.8 16 1.6 20.2 11.8 15.7 1.7 20.2 11.1 131 8 129 165 2.7 0 2.8 2.6 04/18/2007 08:20:00 15.1 1.3 19.9 11.1 15 1.4 19.5 11.1 14.7 1.5 19.1 10.7 131 9 130 165 2.7 0 2.8 2.6 04/18/2007 08:30:00 16.1 1.5 20.2 12.2 16.1 1.5 20.2 11.8 15.6 1.6 19.9 11.1 127 8 132 165 2.7 0 2.8 2.6 04/18/2007 08:40:00 16.1 1.3 19.5 12.2 16 1.3 19.1 11.5 15.7 1.5 19.1 9.9 133 9 140 165 2.7 0 2.8 2.6 04/18/2007 08:50:00 16 1.3 19.9 12.6 16 1.3 20.2 11.5 15.7 1.5 20.6 11.1 133 7 149 165 2.7 0 2.8 2.6 04/18/2007 09:00:00 16.4 1.5 19.9 11.8 16.3 1.5 19.9 12.2 15.9 1.7 20.2 11.8 131 7 128 165 2.7 0 2.8 2.6 04/18/2007 09:10:00 15.8 1.5 19.9 11.8 15.8 1.5 19.9 11.5 15.4 1.6 19.5 10.7 127 8 128 165 2.7 0 2.8 2.6 04/18/2007 09:20:00 14.9 1.7 19.5 10.3 14.8 1.8 19.1 10.7 14.3 1.9 19.1 9.9 126 9 116 165 2.7 0 2.8 2.6 04/18/2007 09:30:00 16 1.6 19.9 11.5 16 1.6 20.2 11.5 15.5 1.7 19.9 11.5 130 9 129 165 2.8 0 3 2.6 04/18/2007 09:40:00 16.8 1.6 20.6 12.2 16.8 1.6 20.6 13 16.3 1.7 20.2 11.5 131 7 128 165 2.8 0 3 2.6 04/18/2007 09:50:00 15.3 1.5 19.1 11.8 15.3 1.5 19.9 11.8 14.9 1.7 19.5 11.5 130 7 116 165 2.9 0 3 2.6 04/18/2007 10:00:00 15.5 1.7 20.6 10.7 15.5 1.7 20.6 10.3 15.1 2 19.9 9.5 126 9 123 165 2.8 0 3 2.6 04/18/2007 10:10:00 15.3 1.9 19.5 9.5 15.2 1.9 19.9 9.9 14.9 2.1 20.2 10.3 130 8 124 165 2.9 0 3 2.8 04/18/2007 10:20:00 15.5 1.5 19.1 11.8 15.5 1.5 19.1 12.2 15.1 1.6 19.1 11.1 132 7 135 165 2.9 0 3 2.8 04/18/2007 10:30:00 15.6 1.7 19.5 11.8 15.5 1.7 19.5 11.8 15.3 1.7 19.5 10.3 133 6 136 165 2.9 0 3 2.8 04/18/2007 10:40:00 15.2 1.6 19.1 11.5 15.2 1.6 19.1 11.5 14.8 1.7 19.1 10.7 129 7 126 165 2.9 0 3 2.8 04/18/2007 10:50:00 15.8 1.2 19.1 11.5 15.8 1.2 19.1 11.8 15.5 1.3 19.1 11.8 129 9 128 165 2.9 0 3 2.8 04/18/2007 11:00:00 15.1 1.7 19.1 9.9 15.2 1.7 19.9 9.9 14.8 1.7 18.7 10.3 128 8 123 165 2.9 0 3 2.8 04/18/2007 11:10:00 14.7 1.5 17.9 9.9 14.7 1.4 18.3 11.1 14.5 1.6 18.7 10.3 132 8 134 165 2.9 0 3 2.8 04/18/2007 11:20:00 15.1 1.5 19.5 9.9 15.1 1.5 19.1 9.5 14.8 1.7 19.9 10.7 130 7 133 165 2.9 0 3 2.6 04/18/2007 11:30:00 13.8 1.6 18.7 10.3 13.8 1.6 18.7 10.3 13.5 1.6 18.3 9.9 129 6 126 165 2.9 0 3 2.8 04/18/2007 11:40:00 13.8 1.6 17.2 9.1 13.8 1.6 17.2 9.5 13.3 1.6 16.8 8.8 129 8 128 165 3 0 3.3 2.8 04/18/2007 11:50:00 14.2 1.4 17.9 9.9 14.3 1.5 17.9 9.1 13.9 1.5 17.6 9.9 124 9 130 165 3 0 3.3 2.8 04/18/2007 12:00:00 13.5 1.4 18.3 8.8 13.5 1.4 18.3 8.8 13 1.5 17.6 9.1 123 9 135 165 3 0 3.3 2.8 04/18/2007 12:10:00 13.7 1.3 17.2 9.9 13.7 1.3 17.2 9.9 13.4 1.3 16.8 9.5 126 7 130 165 3 0 3.3 2.8 04/18/2007 12:20:00 13.9 1.3 17.2 11.1 14 1.3 17.6 10.7 13.6 1.3 16.8 9.9 126 6 124 165 3.1 0 3.3 3 04/18/2007 12:30:00 13.5 1.3 17.2 10.3 13.6 1.3 16.8 10.3 13.2 1.4 17.2 9.5 124 7 128 165 3.1 0 3.3 3 04/18/2007 12:40:00 12.9 1.3 16.4 9.5 13 1.3 16.4 9.5 12.6 1.5 16.8 9.5 124 6 128 165 3.2 0 3.3 3 04/18/2007 12:50:00 12.8 1.2 15.6 9.9 12.9 1.3 15.6 9.9 12.5 1.2 16.1 9.5 122 7 112 165 3.2 0 3.5 3 04/18/2007 13:00:00 11.9 1.3 16.1 8.4 12 1.4 15.6 7.6 11.8 1.4 14.9 8 119 8 110 165 3.2 0 3.5 3 04/18/2007 13:10:00 12.2 1.2 15.3 9.1 12.2 1.2 14.9 9.1 11.9 1.3 15.3 8.8 123 7 127 165 3.2 0 3.5 3 04/18/2007 13:20:00 11.9 1 14.9 9.5 11.9 1 14.9 9.5 11.5 1.1 15.3 8.8 122 6 124 165 3.3 0 3.5 3.3 04/18/2007 13:30:00 12.4 1.3 16.1 8.8 12.5 1.4 16.1 8.8 12.1 1.4 15.3 8 122 8 121 165 3.3 0 3.5 3 04/18/2007 13:40:00 11.5 1.1 14.5 8.8 11.5 1.2 14.5 8.8 11.1 1.2 13.7 7.6 125 7 124 165 3.3 0 3.5 3.3 04/18/2007 13:50:00 11.2 0.9 14.1 8.8 11.3 0.9 14.1 8.8 11.1 1 15.6 8.4 129 7 128 165 3.2 0 3.5 3 04/18/2007 14:00:00 11.6 1.2 14.5 8.8 11.5 1.2 14.5 8.4 11.2 1.3 14.1 7.6 129 7 131 165 3.2 0 3.3 3 04/18/2007 14:10:00 11.2 1.1 14.9 8 11.1 1.2 14.5 8 10.9 1.2 14.5 7.6 132 11 136 165 3.1 0 3.3 2.8 04/18/2007 14:20:00 11.4 1.3 14.5 8.4 11.3 1.3 14.1 8.4 11.3 1.3 14.5 8.4 139 8 145 165 2.8 0 3 2.6 04/18/2007 14:30:00 9.5 1 13 5.7 9.5 1 12.6 6.1 9.3 1.1 12.6 6.5 124 9 119 165 3 0 3.3 2.8 04/18/2007 14:40:00 10.8 1 14.1 8.8 10.8 1 14.1 8.8 10.4 1.2 13.7 7.2 123 8 128 165 2.9 0 3.3 2.6 04/18/2007 14:50:00 11.2 1 14.1 9.1 11.2 1 13.3 9.1 11 1 13.3 8.4 121 7 121 165 2.7 0 3 2.6 04/18/2007 15:00:00 9.4 1.3 13.7 6.8 9.4 1.4 13.7 7.2 9.2 1.3 13.3 6.1 126 8 112 165 2.8 0 3 2.6 04/18/2007 15:10:00 11.6 1.1 14.1 8.8 11.5 1.1 14.5 9.1 11.2 1.2 14.5 8 128 7 119 165 2.7 0 2.8 2.6 04/18/2007 15:20:00 11.1 1 14.1 8.8 11 1 13.7 8.8 10.7 1 13.7 8.4 133 7 135 165 2.5 0 2.8 2.3 04/18/2007 15:30:00 12 1 14.1 9.1 11.9 1 14.1 8.8 11.9 1 14.9 8.8 135 6 132 165 2.4 0 2.6 2.3 04/18/2007 15:40:00 10.7 1.2 13.3 8.4 10.6 1.2 13.3 8.4 10.5 1.2 13.3 8 135 6 132 165 2.3 0 2.6 2.1 04/18/2007 15:50:00 9.9 0.8 11.8 7.6 9.8 0.8 11.8 7.6 9.7 1 11.8 6.5 135 6 141 165 2.3 0 2.6 2.1 04/18/2007 16:00:00 9.1 0.8 11.1 6.8 9 0.8 11.5 7.2 9 0.8 11.1 6.8 138 6 127 165 2.1 0 2.3 1.8 04/18/2007 16:10:00 8.7 0.8 10.3 6.8 8.6 0.8 10.3 6.8 8.6 0.8 11.1 6.1 145 5 140 165 2.1 0 2.6 1.8 04/18/2007 16:20:00 8.5 0.8 10.3 6.1 8.4 0.8 9.9 5.7 8.3 0.9 10.3 6.1 138 7 145 165 2 0 2.3 1.8 04/18/2007 16:30:00 8.2 0.9 10.3 6.1 8.1 0.8 9.9 6.1 7.9 0.9 9.5 5.7 132 6 130 165 2 0 2.3 1.8 04/18/2007 16:40:00 6.7 0.7 8.4 4.2 6.7 0.7 8.4 4.6 6.6 0.6 8.4 4.9 133 9 118 165 2 0 2.3 1.8 04/18/2007 16:50:00 5.8 0.6 7.2 3.8 5.9 0.5 7.2 4.6 5.8 0.6 6.8 3.8 130 8 134 165 2 0 2.3 1.8 04/18/2007 17:00:00 5.5 0.9 8.8 3 5.7 0.8 8.4 3.4 5.7 0.7 8.4 3.8 125 9 128 165 2 0 2.3 1.8 04/18/2007 17:10:00 6.3 0.9 8.4 3.8 6.4 0.9 8.4 3.8 6.2 1 8.4 3.4 119 9 113 165 2 0 2.3 1.8 04/18/2007 17:20:00 6.1 0.6 7.6 4.2 6.2 0.6 7.6 4.2 6.1 0.5 7.2 4.2 121 7 129 165 1.9 0 2.1 1.8 04/18/2007 17:30:00 5.6 0.8 7.6 4.2 5.7 0.7 7.6 4.2 5.6 0.8 7.6 4.2 132 6 133 165 1.9 0 2.3 1.8 04/18/2007 17:40:00 5.7 0.8 7.2 3.8 5.8 0.8 7.2 3.8 5.7 0.8 7.2 3.8 125 8 112 165 1.9 0 2.1 1.8 04/18/2007 17:50:00 5.7 0.6 6.8 4.6 5.9 0.6 7.2 4.6 5.8 0.6 7.2 3.8 120 6 121 165 1.9 0 1.8 1.8 04/18/2007 18:00:00 5.5 0.5 6.5 3.8 5.8 0.5 6.8 3.8 5.4 0.6 6.5 3.8 109 6 114 165 1.9 0 2.1 1.8 04/18/2007 18:10:00 5.2 0.4 6.1 3.8 5.5 0.4 6.5 4.2 5.1 0.5 6.1 3.4 110 6 110 165 1.8 0 1.8 1.6 04/18/2007 18:20:00 4.7 0.4 5.7 3.8 5 0.4 6.1 3.8 4.6 0.5 6.1 3 109 5 110 165 1.8 0 1.8 1.6 04/18/2007 18:30:00 3.9 0.6 5.3 2.3 4.2 0.7 5.7 2.3 4 0.7 5.3 1.9 102 7 105 165 1.8 0 1.8 1.6 04/18/2007 18:40:00 4.5 0.7 5.7 1.9 4.7 0.7 6.1 1.9 4.4 0.8 5.3 1.5 91 6 85 165 1.8 0 1.8 1.6 04/18/2007 18:50:00 4.8 0.5 5.7 3.4 5.1 0.5 6.1 3.8 4.7 0.6 6.1 3 94 5 84 165 1.8 0 1.8 1.6 04/18/2007 19:00:00 5.1 0.4 6.1 4.2 5.4 0.4 6.5 4.6 5.1 0.4 6.1 3.8 99 5 96 165 1.8 0 1.8 1.6 04/18/2007 19:10:00 5.5 0.4 6.8 4.2 5.8 0.4 6.8 4.6 5.4 0.5 6.8 3.8 95 5 101 165 1.8 0 1.8 1.6 04/18/2007 19:20:00 5.5 0.8 7.6 3.8 5.8 0.8 7.6 3.4 5.4 0.9 7.6 3.4 104 7 101 165 1.7 0 1.8 1.6 04/18/2007 19:30:00 5.6 0.7 6.8 3.8 5.9 0.8 7.2 3.8 5.4 0.9 7.2 3.4 103 7 96 165 1.7 0 1.8 1.6 04/18/2007 19:40:00 5.1 0.5 6.1 3.8 5.4 0.5 6.5 3.8 4.9 0.6 6.1 3.4 104 6 103 165 1.7 0 1.8 1.6 04/18/2007 19:50:00 6.3 0.6 8 4.9 6.5 0.5 8 4.9 6.2 0.6 7.6 4.6 105 6 98 165 1.7 0 1.8 1.6 04/18/2007 20:00:00 5.3 0.8 6.8 3 5.5 0.8 7.6 3 5.2 0.8 7.2 3.4 102 7 107 165 1.6 0 1.8 1.4 04/18/2007 20:10:00 5.8 0.6 7.2 3.4 5.9 0.6 7.2 3.4 5.5 0.8 7.2 3 101 5 105 165 1.6 0 1.8 1.4 04/18/2007 20:20:00 5.4 0.5 6.5 4.2 5.7 0.5 6.8 4.2 5.4 0.6 6.8 4.2 99 5 98 165 1.5 0 1.6 1.4 04/18/2007 20:30:00 5.1 0.4 6.5 3.8 5.5 0.4 6.5 3.8 5.1 0.5 6.5 3.8 94 5 98 165 1.5 0 1.6 1.4 04/18/2007 20:40:00 4.7 0.5 5.7 3.4 5.1 0.5 6.1 3.8 4.9 0.4 5.7 3.4 92 2 91 165 1.5 0 1.6 1.4 04/18/2007 20:50:00 4.5 0.4 5.3 3.8 4.9 0.4 5.7 4.2 4.8 0.4 6.1 3.4 90 1 89 165 1.5 0 1.6 1.4 04/18/2007 21:00:00 4.4 0.5 5.3 3 4.8 0.5 6.1 3.4 4.4 0.6 5.7 3 89 0 89 165 1.5 0 1.6 1.4 04/18/2007 21:10:00 5 0.5 6.1 3 5.4 0.5 6.5 3.4 5.1 0.5 6.5 3.4 90 0 90 165 1.5 0 1.6 1.4 04/18/2007 21:20:00 5.1 0.4 6.1 4.2 5.5 0.4 6.5 4.6 5.3 0.4 6.5 4.2 90 0 90 165 1.5 0 1.6 1.4 04/18/2007 21:30:00 4.9 0.4 5.7 3.8 5.3 0.4 6.1 4.6 5 0.4 6.1 3.8 90 0 90 165 1.5 0 1.6 1.4 04/18/2007 21:40:00 4.7 0.4 5.7 3.4 5.2 0.5 6.1 4.2 4.8 0.5 6.1 3.4 90 0 90 165 1.5 0 1.6 1.4 04/18/2007 21:50:00 4.6 0.5 5.3 3 5 0.5 5.7 3.4 4.9 0.5 5.7 3.4 90 0 90 165 1.5 0 1.6 1.4 04/18/2007 22:00:00 4.4 0.3 5.3 3.4 4.8 0.3 5.7 3.8 4.6 0.4 5.7 3.4 90 0 90 165 1.5 0 1.6 1.4 04/18/2007 22:10:00 4 0.3 4.9 3.4 4.4 0.3 5.3 3.8 4.4 0.3 5.3 3.4 90 0 90 165 1.5 0 1.6 1.4 04/18/2007 22:20:00 4.1 0.5 4.9 3 4.6 0.4 5.3 3.4 4.5 0.5 5.3 3 90 0 90 165 1.5 0 1.8 1.4 04/18/2007 22:30:00 4.1 0.5 4.9 2.6 4.6 0.5 5.7 3.4 4.3 0.4 5.3 3 90 0 91 165 1.6 0 1.6 1.4 04/18/2007 22:40:00 4.9 0.5 5.7 3.8 5.4 0.5 6.5 4.2 5 0.5 6.1 3.4 90 0 91 165 1.6 0 1.6 1.4 04/18/2007 22:50:00 5.4 0.5 6.5 3.4 5.9 0.5 6.5 3.8 5.5 0.6 6.8 3.8 91 0 91 165 1.6 0 1.6 1.4 04/18/2007 23:00:00 5.4 0.4 6.5 4.2 5.8 0.3 6.8 4.6 5.5 0.5 6.5 3.8 91 0 91 165 1.5 0 1.6 1.4 04/18/2007 23:10:00 4.9 0.7 6.1 3 5.4 0.6 6.5 3.4 5.1 0.7 6.5 3.4 91 0 91 165 1.6 0 1.8 1.4 04/18/2007 23:20:00 4.6 0.5 6.1 3 5.1 0.5 6.5 3.8 4.8 0.5 6.1 3 91 0 91 165 1.5 0 1.6 1.4 04/18/2007 23:30:00 4.4 0.5 6.1 3.4 4.9 0.5 6.5 3.8 4.7 0.6 6.5 3 92 0 92 165 1.5 0 1.6 1.4 04/18/2007 23:40:00 4.9 0.5 6.1 3.4 5.3 0.5 6.5 3.8 5.1 0.6 6.5 3 92 0 92 165 1.5 0 1.6 1.4 04/18/2007 23:50:00 4.6 0.5 5.7 3.4 4.9 0.5 6.1 3.8 4.7 0.5 6.1 3.4 92 0 92 165 1.5 0 1.6 1.4 04/19/2007 00:00:00 4.9 0.9 6.8 3.4 5.3 0.9 6.8 3.8 5 0.9 7.2 3.4 93 0 93 165 1.5 0 1.6 1.4 04/19/2007 00:10:00 5 0.5 6.1 3.4 5.3 0.6 6.5 3.4 5.3 0.7 6.5 3.4 93 0 93 165 1.5 0 1.6 1.4 04/19/2007 00:20:00 3.5 0.5 4.9 2.3 3.5 0.5 4.9 2.3 3.8 0.5 5.3 2.3 94 0 94 165 1.4 0 1.6 1.4 04/19/2007 00:30:00 3.7 0.4 4.9 2.6 3.7 0.5 4.9 2.3 3.9 0.5 4.9 2.6 94 0 94 165 1.4 0 1.6 1.4 04/19/2007 00:40:00 3.6 0.5 4.9 2.3 3.5 0.5 4.9 2.3 3.6 0.6 5.3 1.9 94 0 94 165 1.4 0 1.6 1.4 04/19/2007 00:50:00 3.8 0.4 4.6 2.3 3.7 0.4 4.6 1.9 3.9 0.5 4.9 2.6 95 0 95 165 1.5 0 1.6 1.4 04/19/2007 01:00:00 3.3 0.5 4.2 2.3 3.3 0.6 4.2 1.9 3.6 0.5 4.6 2.3 95 1 95 165 1.5 0 1.6 1.4 04/19/2007 01:10:00 2.1 0.4 3 1.1 1.4 0.8 2.6 0.4 2.4 0.4 3 1.5 97 0 98 165 1.5 0 1.6 1.4 04/19/2007 01:20:00 3.9 1 5.7 1.1 0.4 0 0.4 0.4 3.9 1 6.1 1.5 97 0 98 165 1.5 0 1.8 1.4 04/19/2007 01:30:00 5 0.6 6.1 3 0.4 0 0.4 0.4 5.1 0.6 6.5 3 98 0 98 165 1.6 0 1.8 1.6 04/19/2007 01:40:00 5.3 0.8 7.2 3.4 0.4 0 0.4 0.4 5.6 0.7 7.6 3.8 98 0 98 165 1.7 0 1.8 1.6 04/19/2007 01:50:00 6.9 0.5 8 4.9 0.4 0 0.4 0.4 7 0.7 8.8 4.6 98 0 98 165 1.8 0 1.8 1.6 04/19/2007 02:00:00 7.2 0.4 8 5.7 0.4 0 0.4 0.4 7.4 0.6 8.4 5.3 98 0 98 165 1.9 0 1.8 1.8 04/19/2007 02:10:00 7.6 0.7 9.5 5.3 0.4 0 0.4 0.4 7.7 0.7 9.5 5.7 97 0 98 165 2 0 2.3 1.8 04/19/2007 02:20:00 8.6 0.6 10.3 6.5 0.4 0 0.7 0.4 8.6 0.7 10.7 6.5 98 0 98 165 2.3 0 2.6 2.1 04/19/2007 02:30:00 8.8 0.6 10.3 6.8 7.7 3.2 10.7 0.4 8.7 0.6 10.3 6.8 98 0 98 165 2.3 0 2.6 2.3 04/19/2007 02:40:00 8.6 1 10.3 5.3 8.8 1 10.7 5.7 8.3 1 10.7 4.6 99 0 98 165 2.3 0 2.6 2.3 04/19/2007 02:50:00 8 0.9 10.3 6.1 8.3 0.8 10.7 6.1 7.7 0.8 9.9 5.3 100 0 99 165 2.3 0 2.6 2.1 04/19/2007 03:00:00 7.8 0.8 9.5 5.3 8.1 0.8 9.9 5.3 7.6 0.9 9.5 5.3 106 5 101 165 2.3 0 2.6 2.3 04/19/2007 03:10:00 6.7 0.8 9.1 4.9 7 0.7 9.1 5.3 6.7 0.8 8.8 4.6 119 3 116 165 2.3 0 2.6 2.1 04/19/2007 03:20:00 6.7 0.6 8.8 4.9 6.9 0.6 9.1 4.9 6.7 0.7 8.8 4.9 122 5 114 165 2.3 0 2.6 2.3 04/19/2007 03:30:00 7.1 0.7 9.1 5.7 7.3 0.7 9.1 6.1 7 0.7 8.8 5.7 123 6 126 165 2.3 0 2.6 2.1 04/19/2007 03:40:00 8.1 0.8 11.1 5.3 8.2 0.8 11.5 5.7 8 0.9 11.5 5.7 126 7 120 165 2.3 0 2.6 2.1 04/19/2007 03:50:00 9 0.9 11.1 6.5 9.1 0.9 11.1 6.1 8.8 0.9 11.1 5.7 122 6 113 165 2.1 0 2.3 1.8 04/19/2007 04:00:00 9.4 1.1 11.8 5.7 9.5 1.1 12.2 6.5 9.1 1.1 12.2 6.5 129 7 128 165 2.1 0 2.3 1.8 04/19/2007 04:10:00 10.5 0.8 12.2 8 10.4 0.8 12.2 8 10.2 0.7 11.8 8.4 133 6 129 165 2.1 0 2.3 1.8 04/19/2007 04:20:00 10.2 0.8 12.6 8.4 10.1 0.8 12.6 8 10.1 0.9 12.6 7.6 137 5 135 165 2 0 2.3 1.8 04/19/2007 04:30:00 8.7 1 10.7 5.3 8.6 1 10.3 5.3 8.5 1.1 10.3 4.9 137 8 145 165 2 0 2.3 1.8 04/19/2007 04:40:00 7.5 0.7 9.1 6.1 7.4 0.7 9.1 5.7 7.4 0.7 9.1 5.7 137 6 138 165 2 0 2.3 1.8 04/19/2007 04:50:00 8.6 0.9 10.3 6.1 8.5 0.8 10.3 6.5 8.3 1 10.7 6.1 135 6 138 165 2.1 0 2.3 1.8 04/19/2007 05:00:00 9.9 0.9 12.2 7.6 9.8 0.9 12.2 7.2 9.7 1.1 12.2 6.8 137 7 140 165 2.1 0 2.3 2.1 04/19/2007 05:10:00 10.3 0.6 11.8 8.8 10.2 0.6 11.8 8.8 10.2 0.6 12.2 8.4 140 5 147 165 2.1 0 2.3 1.8 04/19/2007 05:20:00 9.7 0.4 10.7 8.8 9.5 0.4 10.7 8.4 9.4 0.5 10.7 8 145 3 144 165 2 0 2.3 1.8 04/19/2007 05:30:00 9 0.5 10.3 7.2 8.9 0.5 10.3 7.6 8.9 0.6 10.3 7.2 146 3 147 165 2 0 2.3 1.8 04/19/2007 05:40:00 8.5 0.4 9.5 6.8 8.3 0.4 9.1 6.8 8.4 0.4 9.1 7.2 146 3 147 165 2 0 2.3 1.8 04/19/2007 05:50:00 7.2 0.5 8.4 5.3 7.2 0.5 8.4 5.7 7 0.6 8.4 5.3 143 5 140 165 2 0 2.3 1.8 04/19/2007 06:00:00 8.6 1.1 10.7 5.7 8.5 1.1 11.1 6.1 8.5 1 11.5 6.1 139 7 135 165 2.1 0 2.3 1.8 04/19/2007 06:10:00 9.2 0.8 10.7 6.8 9.2 0.8 10.7 6.8 9 1 10.7 6.8 140 5 133 165 2.2 0 2.3 1.8 04/19/2007 06:20:00 9.6 0.5 10.7 8 9.5 0.6 10.7 7.6 9.4 0.6 11.1 7.2 140 5 145 165 2.2 0 2.3 2.1 04/19/2007 06:30:00 10.1 0.7 11.8 8.4 10.1 0.7 11.8 8 9.8 0.8 11.5 7.2 137 5 143 165 2.1 0 2.3 2.1 04/19/2007 06:40:00 10.7 0.5 12.2 9.5 10.6 0.5 11.8 9.1 10.6 0.6 12.2 8.8 142 4 146 165 2.1 0 2.3 1.8 04/19/2007 06:50:00 12.3 0.9 14.1 9.9 12.2 1 13.7 9.9 12.1 1.1 14.1 8.8 145 4 145 165 2 0.1 2.3 1.8 04/19/2007 07:00:00 12.5 0.9 14.1 10.3 12.4 0.9 14.1 10.3 12.4 1 14.5 9.1 145 5 146 165 1.7 0 1.8 1.4 04/19/2007 07:10:00 13.6 0.7 15.6 11.5 13.5 0.7 15.3 11.5 13.6 0.8 15.6 10.3 148 5 148 165 1.5 0 1.6 1.4 04/19/2007 07:20:00 13.2 0.8 15.3 11.1 13.1 0.8 14.9 10.7 13.4 0.9 15.3 10.7 150 2 151 165 1.5 0 1.6 1.4 04/19/2007 07:30:00 12.2 0.7 14.1 10.3 12.2 0.7 14.1 9.9 12.5 0.8 14.1 9.9 151 0 151 165 1.4 0 1.6 1.1 04/19/2007 07:40:00 11.1 1.3 13.3 7.2 11.1 1.2 13.3 7.6 11.4 1.4 15.3 7.6 152 0 151 165 1 0.1 1.4 0.7 04/19/2007 07:50:00 11.7 0.7 13.3 9.5 11.6 0.7 13 9.1 12.1 0.8 13.7 9.9 152 0 152 165 0.6 0 0.9 0.2 04/19/2007 08:00:00 11.3 0.5 12.6 9.5 11.2 0.5 12.6 9.9 11.8 0.6 13.3 9.9 153 0 153 165 0.2 0 0.4 0.2 04/19/2007 08:10:00 12.2 0.6 13.3 10.3 12.2 0.6 13.3 9.9 12.7 0.7 14.1 10.7 153 0 153 165 0.2 0 0.4 0.2 04/19/2007 08:20:00 11.3 0.6 13 9.5 11.2 0.6 12.6 9.5 11.7 0.7 13.3 9.5 153 0 153 165 0.2 0 0.4 -0.1 04/19/2007 08:30:00 10.7 0.4 11.5 9.5 10.7 0.4 11.5 9.5 11.1 0.4 11.8 9.5 153 0 153 165 0.2 0 0.4 0.2 04/19/2007 08:40:00 10.3 0.4 11.5 9.1 10.3 0.4 11.5 9.1 10.7 0.5 11.8 9.1 153 0 153 165 0.2 0 0.4 -0.1 04/19/2007 08:50:00 9.9 0.5 11.1 8.4 9.9 0.5 11.1 8.4 10.2 0.6 11.5 8.4 153 0 153 165 0.2 0 0.7 0.2 04/19/2007 09:00:00 10 0.5 11.1 8.4 9.9 0.5 11.1 8.4 10.3 0.5 11.5 8 153 0 153 165 0.3 0 0.7 0.2 04/19/2007 09:10:00 10.1 0.6 12.2 8 10 0.6 11.8 8 10.4 0.6 12.2 8.8 153 0 153 165 0.4 0 0.7 0.2 04/19/2007 09:20:00 9.7 0.8 11.8 8 9.6 0.7 11.5 8.4 9.9 0.8 12.6 8.4 153 0 153 165 0.4 0 0.7 0.2 04/19/2007 09:30:00 10.4 0.8 12.6 8.4 10.3 0.7 12.2 8 10.7 0.8 13 8.4 153 0 153 165 0.3 0 0.4 0.2 04/19/2007 09:40:00 12.6 0.8 15.3 10.3 12.5 0.8 14.5 9.9 13 0.9 15.3 10.7 153 0 153 165 0.2 0 0.4 0.2 04/19/2007 09:50:00 11.5 0.7 13.7 9.1 11.6 0.7 13.3 9.1 11.9 0.7 13.3 9.5 153 0 153 165 0.3 0 0.7 0.2 04/19/2007 10:00:00 11.7 0.9 13.7 9.5 11.7 0.9 13.7 9.1 11.9 1 14.5 9.5 153 0 153 165 0.3 0 0.7 0.2 04/19/2007 10:10:00 10.8 0.6 12.6 8.4 10.7 0.6 12.2 8.8 11.1 0.6 12.2 9.1 153 0 153 165 0.5 0 0.7 0.2 04/19/2007 10:20:00 11.9 1 14.1 9.1 11.8 1 13.7 8.8 12.1 1 14.5 9.1 153 0 153 165 0.3 0.1 0.7 0.2 04/19/2007 10:30:00 10.9 0.9 13.3 8.8 10.8 1 13 8.8 11.1 1.1 13.3 8.8 153 0 153 165 0.3 0 0.7 0.2 04/19/2007 10:40:00 9.6 0.7 11.1 7.6 9.5 0.7 11.1 7.2 9.9 0.8 11.8 7.2 153 0 153 165 0.2 0 0.4 -0.1 04/19/2007 10:50:00 11.2 1.2 13.7 8.4 11.1 1.1 13.3 8.4 11.5 1.1 13.7 8.8 153 0 153 165 0.2 0 0.4 -0.1 04/19/2007 11:00:00 13.1 1.3 16.4 10.3 13 1.3 16.4 9.9 13.5 1.5 16.4 9.9 153 0 153 165 0.2 0 0.4 -0.1 04/19/2007 11:10:00 12 1.3 15.6 8 12 1.3 15.3 8 12.6 1.3 16.1 9.1 153 0 153 165 0.2 0 0.2 -0.1 04/19/2007 11:20:00 11.9 1.1 14.1 8.8 11.9 1.1 14.1 9.1 12.3 1.2 14.5 9.5 153 0 153 165 0.1 0 0.4 -0.1 04/19/2007 11:30:00 13 0.7 14.9 11.1 13 0.7 14.9 11.5 13.4 0.7 15.3 11.5 153 0 153 165 0 0 0.2 -0.1 04/19/2007 11:40:00 12.4 0.7 14.1 10.7 12.5 0.7 14.1 10.3 12.8 0.7 14.5 10.3 153 0 153 165 0 0 0.2 -0.1 04/19/2007 11:50:00 10.9 0.8 13 9.1 10.9 0.8 13 9.1 11.2 0.8 13.3 8.8 153 0 153 165 0 0 0.2 -0.1 04/19/2007 12:00:00 10.5 0.4 11.5 9.1 10.5 0.4 11.5 8.8 10.7 0.5 12.2 9.5 153 0 153 165 0.1 0 0.2 -0.1 04/19/2007 12:10:00 9.8 0.7 11.8 8 9.8 0.7 11.5 8 10 0.8 12.6 8 153 0 153 165 0.1 0 0.2 -0.1 04/19/2007 12:20:00 10.4 0.6 11.8 8.4 10.3 0.6 11.8 8.4 10.5 0.8 12.6 7.2 153 0 153 165 0.1 0 0.2 -0.1 04/19/2007 12:30:00 10.2 0.6 11.5 8 10.2 0.6 11.5 8.4 10.4 0.8 11.8 6.8 153 0 153 165 0.1 0 0.2 -0.1 04/19/2007 12:40:00 10.2 0.6 11.5 8.8 10.1 0.6 11.8 8.4 10.2 0.6 11.5 7.6 153 0 153 165 0.2 0 0.2 -0.1 04/19/2007 12:50:00 10.6 0.5 11.8 9.1 10.5 0.5 11.5 9.1 10.7 0.5 12.2 9.1 153 0 153 165 0.2 0 0.4 -0.1 04/19/2007 13:00:00 10.7 0.6 12.6 8.8 10.6 0.6 12.6 8.8 10.8 0.7 13 9.1 153 0 153 165 0.2 0 0.2 -0.1 04/19/2007 13:10:00 11.3 0.9 13.3 9.5 11.3 0.9 13.3 9.1 11.2 1 13.3 8.4 148 4 147 165 0.2 0 0.4 0.2 04/19/2007 13:20:00 12.1 0.7 13.3 10.3 12 0.7 13.3 10.3 12.1 0.8 13.7 9.9 149 2 150 165 0.2 0 0.4 -0.1 04/19/2007 13:30:00 11.7 0.5 13 9.9 11.7 0.5 13 9.9 11.9 0.5 13.3 10.3 153 1 154 165 0.3 0 0.7 0.2 04/19/2007 13:40:00 12 0.6 14.5 10.7 12 0.6 14.1 10.3 12.2 0.7 14.5 10.3 153 0 154 165 0.2 0.1 0.7 -0.1 04/19/2007 13:50:00 10.7 0.6 12.2 9.1 10.6 0.6 12.2 8.8 10.8 0.7 13 8.8 153 0 154 165 0.1 0 0.2 -0.1 04/19/2007 14:00:00 12.4 1 14.9 9.9 12.4 1 15.3 10.3 12.5 1 14.9 9.1 153 0 153 165 0.1 0 0.2 -0.1 04/19/2007 14:10:00 13.2 1.1 16.4 10.3 13.1 1.1 16.1 10.3 13.3 1.2 16.1 10.3 153 0 153 165 -0.1 0 0.2 -0.3 04/19/2007 14:20:00 11.1 0.6 12.6 9.5 11 0.5 12.2 9.5 11.2 0.6 12.6 9.1 153 0 154 165 0.1 0 0.2 -0.1 04/19/2007 14:30:00 10.8 0.5 12.2 9.5 10.7 0.5 11.8 9.1 11 0.6 12.6 9.5 153 0 154 165 0.1 0 0.2 -0.1 04/19/2007 14:40:00 10.8 1.3 14.9 8.4 10.8 1.2 14.5 8.4 10.9 1.4 14.1 7.2 153 0 153 165 0.1 0 0.2 -0.1 04/19/2007 14:50:00 12.8 1.1 14.5 9.9 12.6 1.1 14.5 9.9 12.8 1.4 14.9 9.1 153 0 154 165 0.2 0 0.7 0.2 04/19/2007 15:00:00 12 0.8 14.1 9.5 12 0.8 13.7 9.1 12.2 0.8 14.1 8.4 153 0 153 165 0.2 0 0.4 0.2 04/19/2007 15:10:00 12.2 1.1 15.6 9.1 12.1 1.1 15.6 9.5 12.2 1.3 16.4 9.1 153 0 153 165 0.2 0 0.7 0.2 04/19/2007 15:20:00 15.3 1.3 19.1 11.1 15.2 1.3 18.7 11.1 15.3 1.4 18.3 10.7 153 0 153 165 0.2 0 0.2 0.2 04/19/2007 15:30:00 14.2 0.9 16.8 11.5 14.2 0.8 16.8 11.8 14.3 0.9 16.8 11.5 153 0 153 165 0.2 0 0.2 -0.1 04/19/2007 15:40:00 14.3 1 16.8 12.2 14.2 1 16.4 11.5 14.5 1.1 17.6 11.8 153 0 153 165 0 0 0.2 -0.3 04/19/2007 15:50:00 13.4 0.9 15.3 10.7 13.3 0.9 15.3 11.1 13.5 1 15.3 9.9 153 0 153 165 0.1 0 0.4 -0.1 04/19/2007 16:00:00 14.2 1.2 17.6 10.3 14.2 1.2 17.6 10.3 14 1.2 17.6 11.5 153 0 153 165 0.2 0 0.7 0.2 04/19/2007 16:10:00 15 1.1 17.9 11.1 15 1.1 17.9 11.1 15 1.3 18.3 12.2 153 0 153 165 0.3 0.1 0.7 0.2 04/19/2007 16:20:00 14.7 0.7 16.4 13 14.7 0.7 16.4 13 15.1 0.8 17.6 13 153 0 153 165 0.1 0 0.2 -0.1 04/19/2007 16:30:00 13.4 1 15.6 11.5 13.3 0.9 15.6 11.5 13.3 1 15.6 10.3 153 0 153 165 0.2 0 0.7 -0.1 04/19/2007 16:40:00 12.9 0.8 14.5 8.8 12.9 0.7 14.5 9.5 12.8 0.8 14.5 10.3 153 0 153 165 0.4 0 0.7 0.2 04/19/2007 16:50:00 13.5 0.9 15.6 11.1 13.5 0.9 15.6 11.1 13.2 1.1 15.6 9.1 153 0 153 165 0.4 0 0.7 0.2 04/19/2007 17:00:00 13.8 0.8 16.1 11.5 13.7 0.8 16.1 11.5 13.6 1 16.1 11.5 153 0 153 165 0.5 0 0.9 0.2 04/19/2007 17:10:00 14.2 1 16.1 11.5 14.1 0.9 16.1 11.5 14.1 0.9 16.1 12.2 153 0 153 165 0.4 0 0.7 0.2 04/19/2007 17:20:00 14.3 1 16.4 11.8 14.1 1 16.4 12.2 13.9 1.1 16.4 10.7 153 0 153 165 0.4 0 0.7 0.2 04/19/2007 17:30:00 14.2 0.6 16.1 12.2 14.1 0.6 15.6 12.2 14.1 0.7 15.6 11.5 153 0 153 165 0.3 0 0.4 0.2 04/19/2007 17:40:00 13.9 0.8 15.6 11.5 13.9 0.8 15.6 11.8 13.8 0.8 16.1 11.1 153 0 153 165 0.3 0 0.7 0.2 04/19/2007 17:50:00 12.9 1 15.3 9.9 12.8 1 15.3 9.5 12.6 1.1 16.1 8.8 153 0 153 165 0.4 0 0.7 0.2 04/19/2007 18:00:00 13.1 1.1 15.3 10.3 13.1 1.1 15.3 10.3 13.1 1.1 15.6 9.9 153 0 153 165 0.4 0 0.7 0.2 04/19/2007 18:10:00 12.4 0.9 14.9 9.9 12.4 0.9 14.9 10.3 12.4 1 15.3 9.1 153 0 153 165 0.5 0 0.7 0.2 04/19/2007 18:20:00 12.6 0.8 14.5 10.3 12.7 0.8 14.1 10.3 12.6 0.8 15.3 9.9 153 0 153 165 0.5 0 0.7 0.2 04/19/2007 18:30:00 12.4 0.7 14.5 10.3 12.3 0.6 14.1 10.7 12.5 0.8 14.5 9.9 153 0 153 165 0.2 0.1 0.7 0.2 04/19/2007 18:40:00 10.9 0.7 13.7 9.5 10.9 0.7 13.7 9.1 10.9 0.8 13 8.8 153 0 153 165 0.2 0 0.4 -0.1 04/19/2007 18:50:00 11 1.1 13.3 8.4 11.1 1.1 13.3 8.8 11 1.1 13.3 8.4 153 0 153 165 0.3 0 0.7 0.2 04/19/2007 19:00:00 11.1 1 13.7 8.4 11.2 1 13.7 8.8 10.9 1.1 13.3 8 153 0 153 165 0.4 0 0.7 0.2 04/19/2007 19:10:00 10 0.7 11.8 7.6 10.2 0.7 12.2 8 9.8 0.8 11.8 7.2 153 0 153 165 0.2 0 0.4 0.2 04/19/2007 19:20:00 9.4 1 11.8 7.2 9.6 1 12.2 7.6 9.2 1 11.8 6.8 153 0 153 165 0.4 0 0.7 0.2 04/19/2007 19:30:00 10.4 1.1 14.1 7.2 10.5 1.1 14.1 7.6 10.1 1.3 13.7 6.8 153 0 153 165 0.5 0 0.7 0.2 04/19/2007 19:40:00 10.9 1 13.3 8 11 1 13.3 8.4 10.7 1.1 13.7 7.6 153 0 153 165 0.5 0 0.7 0.2 04/19/2007 19:50:00 12 1 14.1 9.1 12.3 1 14.5 9.1 11.7 0.9 14.1 9.5 153 0 153 165 0.5 0 0.7 0.2 04/19/2007 20:00:00 11.1 1 13.7 8.4 11.5 1 13.7 8.8 10.8 1 14.1 8 153 0 153 165 0.5 0 0.7 0.2 04/19/2007 20:10:00 11.9 1 13.7 9.5 12.1 1 14.1 9.5 11.5 1 13.7 8.4 153 0 153 165 0.4 0 0.7 0.2 04/19/2007 20:20:00 11.8 1.1 14.9 9.5 12 1.2 15.3 9.9 11.5 1.1 14.1 8.8 153 0 153 165 0.4 0 0.7 0.2 04/19/2007 20:30:00 12 1 14.5 9.5 12.3 1.1 14.5 9.5 11.9 1.1 14.5 9.5 153 0 153 165 0.3 0.1 0.7 0.2 04/19/2007 20:40:00 10.1 0.7 12.2 8.4 10.4 0.8 12.6 8.8 9.9 0.9 12.2 8 153 0 153 165 0.4 0 0.7 0.2 04/19/2007 20:50:00 10.6 1.1 13.3 8 10.8 1.1 13.3 8.4 10.3 1.1 13 7.6 153 0 153 165 0.4 0 0.7 0.2 04/19/2007 21:00:00 12.4 0.8 14.5 10.3 12.6 0.8 14.5 9.9 12.1 0.9 14.5 9.5 153 0 153 165 0.3 0 0.7 -0.1 04/19/2007 21:10:00 10.3 0.9 12.6 8.4 10.5 0.9 13 8.8 10.2 0.9 12.6 8 153 0 153 165 0.2 0 0.4 -0.1 04/19/2007 21:20:00 10.7 1 12.6 8.4 10.8 1 12.6 8.4 10.5 0.8 12.6 8.4 153 0 153 165 0.3 0 0.7 0.2 04/19/2007 21:30:00 9.9 1.1 12.6 7.2 9.9 1 12.6 7.2 9.7 1 12.2 7.2 153 0 153 165 0.3 0 0.7 0.2 04/19/2007 21:40:00 10.8 1.2 14.1 7.6 10.7 1.3 14.1 7.2 10.5 1.4 13.7 6.1 153 0 153 165 0.4 0 0.7 0.2 04/19/2007 21:50:00 12.5 0.7 14.9 10.3 12.5 0.7 14.5 10.3 12.2 0.9 14.9 8.8 153 0 153 165 0.2 0 0.7 -0.1 04/19/2007 22:00:00 11 1 12.6 8.4 11 1 13 8.4 10.8 1 13 8.4 153 0 153 165 0.1 0 0.2 -0.1 04/19/2007 22:10:00 11 1 13.3 8.8 11 1.1 13.3 8.8 10.7 1.2 13 7.2 153 0 153 165 0.2 0 0.7 0.2 04/19/2007 22:20:00 11.1 0.7 13 9.1 11.1 0.7 13 9.1 10.9 0.8 12.6 8.4 153 0 153 165 0.2 0 0.4 0.2 04/19/2007 22:30:00 10 0.9 12.6 7.6 10 0.9 12.6 8 9.7 1 13 7.6 153 0 153 165 0.3 0 0.7 0.2 04/19/2007 22:40:00 9.8 1 13.3 7.6 10 1 13 7.6 9.7 1.1 13 7.2 153 0 153 165 0.3 0 0.4 0.2 04/19/2007 22:50:00 9.8 1 12.6 7.6 10 1 12.6 7.6 9.7 1.1 13 7.6 153 0 153 165 0.3 0 0.7 0.2 04/19/2007 23:00:00 8.4 1 10.7 5.7 8.6 1.1 11.1 6.1 8.2 1 11.1 5.7 153 0 153 165 0.3 0 0.7 0.2 04/19/2007 23:10:00 7.9 0.9 9.9 5.3 8 0.9 9.9 5.3 7.8 0.9 9.5 6.1 153 0 154 165 0.2 0 0.7 0.2 04/19/2007 23:20:00 8.1 0.8 11.5 6.1 8.3 0.8 11.1 6.5 8.2 0.8 11.5 6.5 153 0 154 165 0.3 0 0.7 0.2 04/19/2007 23:30:00 8.7 1 11.8 6.5 8.8 1 11.8 6.1 8.7 1 11.1 6.5 153 0 154 165 0.4 0 0.7 0.2 04/19/2007 23:40:00 8 1 10.7 6.1 8.2 1 11.1 6.1 8.1 0.9 10.7 5.7 153 0 154 165 0.4 0 0.7 0.2 04/19/2007 23:50:00 9.3 1.6 13.3 5.3 9.5 1.6 13 5.3 9.4 1.5 13.3 6.1 153 0 154 165 0.5 0 0.7 0.2 04/20/2007 00:00:00 10.3 1 13 8.4 10.7 0.9 13 8.8 10.1 1 12.6 7.6 153 0 153 165 0.4 0 0.7 0.2 04/20/2007 00:10:00 8.7 0.9 11.1 6.5 9 0.9 11.5 7.2 8.7 0.9 11.8 6.8 153 0 154 165 0.4 0 0.7 0.2 04/20/2007 00:20:00 7.6 1.3 11.8 4.2 8 1.3 12.2 4.9 7.6 1.5 11.8 4.2 153 0 154 165 0.5 0 0.7 0.2 04/20/2007 00:30:00 8 1.3 11.1 4.9 8.3 1.3 11.5 5.7 7.7 1.3 11.1 4.9 153 0 154 165 0.4 0 0.7 0.2 04/20/2007 00:40:00 6.1 0.7 8 4.6 6.4 0.7 8 4.6 6.2 0.7 8 3.8 153 0 154 165 0.4 0 0.7 0.2 04/20/2007 00:50:00 7.7 0.9 9.9 5.3 7.9 0.9 10.3 5.7 7.4 1 9.5 4.9 153 0 154 165 0.4 0 0.7 0.2 04/20/2007 01:00:00 7.2 0.9 9.5 4.6 7.5 0.9 10.3 4.9 7.1 1 9.9 4.6 153 0 154 165 0.5 0 0.7 0.2 04/20/2007 01:10:00 7.2 0.8 10.3 4.2 7.4 0.9 10.3 4.2 7 1 10.3 4.2 153 0 154 165 0.6 0 0.9 0.4 04/20/2007 01:20:00 7.8 1.2 11.5 5.3 8.2 1.1 11.8 5.7 7.8 1 10.3 5.3 153 0 154 165 0.7 0 0.9 0.4 04/20/2007 01:30:00 6.4 0.6 8 4.2 6.8 0.7 8.8 4.6 6.5 0.7 8.4 4.6 153 0 154 165 0.7 0 0.9 0.4 04/20/2007 01:40:00 6.9 0.8 9.1 4.6 7.3 0.8 9.5 4.9 6.8 0.9 8.8 4.6 153 0 154 165 0.7 0 0.9 0.7 04/20/2007 01:50:00 6.7 0.9 9.5 4.6 6.9 0.9 9.5 4.6 6.3 1 9.5 4.2 153 0 154 165 0.7 0 0.7 0.4 04/20/2007 02:00:00 6.8 1.1 11.8 4.9 7.1 1.1 12.2 4.9 6.3 1 10.7 4.2 153 0 154 165 0.7 0 0.9 0.7 04/20/2007 02:10:00 7.8 0.9 9.9 5.3 8.2 0.9 10.3 5.7 7.8 0.9 9.5 5.3 153 0 154 165 0.7 0 0.9 0.7 04/20/2007 02:20:00 9 1 11.1 6.1 9.7 0.9 11.8 7.2 9.1 1 11.5 6.1 153 0 154 165 0.5 0 0.9 0.4 04/20/2007 02:30:00 8.3 1.2 10.7 6.1 9 1.1 11.5 6.8 8.5 1.2 10.7 6.1 153 0 154 165 0.5 0 0.7 0.2 04/20/2007 02:40:00 8.5 0.7 10.3 6.5 9.2 0.7 11.1 7.6 8.6 0.8 11.1 6.1 153 0 154 165 0.4 0 0.7 0.2 04/20/2007 02:50:00 7.6 0.8 9.5 4.9 8.3 0.8 9.9 5.3 7.8 0.7 9.5 5.7 153 0 154 165 0.3 0 0.7 0.2 04/20/2007 03:00:00 6.1 0.7 7.6 4.6 6.7 0.8 8.8 5.3 6.4 0.8 9.1 4.6 153 0 154 165 0.3 0 0.7 0.2 04/20/2007 03:10:00 4.8 0.7 6.8 3 5 0.8 7.2 3.4 5.1 0.6 6.8 3.8 153 0 154 165 0.4 0 0.7 0.2 04/20/2007 03:20:00 5.1 0.6 6.5 3.8 5.2 0.5 6.5 3.8 5 0.6 6.1 3.4 153 0 154 165 0.5 0 0.7 0.2 04/20/2007 03:30:00 5.8 0.5 7.2 4.2 5.7 0.5 7.2 4.6 5.3 0.6 6.8 3.8 153 0 154 165 0.5 0 0.7 0.2 04/20/2007 03:40:00 5.3 0.4 6.8 4.2 5.2 0.4 6.5 4.2 4.8 0.5 6.1 3.4 153 0 154 165 0.5 0 0.7 0.2 04/20/2007 03:50:00 5.9 0.5 6.8 4.6 5.7 0.5 7.2 4.2 5.8 0.6 7.2 4.2 153 0 154 165 0.5 0 0.7 0.4 04/20/2007 04:00:00 5.6 0.5 7.2 4.2 5.3 0.5 6.8 4.2 5.5 0.5 6.8 4.6 153 0 154 165 0.5 0 0.7 0.4 04/20/2007 04:10:00 5.6 0.5 7.2 4.2 5.3 0.5 6.5 4.2 5.5 0.4 6.8 4.2 153 0 154 165 0.5 0 0.7 0.4 04/20/2007 04:20:00 6 0.5 7.6 4.6 5.5 0.5 7.2 4.2 5.6 0.6 6.8 4.2 153 0 154 165 0.6 0 0.7 0.2 04/20/2007 04:30:00 6.2 0.6 8 4.2 5.9 0.6 7.6 4.2 6 0.6 7.6 4.6 153 0 154 165 0.6 0 0.9 0.4 04/20/2007 04:40:00 6.3 0.6 8.4 4.6 6.2 0.6 8 4.6 6.2 0.6 8 4.6 153 0 154 165 0.6 0 0.7 0.7 04/20/2007 04:50:00 6.2 0.5 7.6 4.6 5.9 0.5 7.2 4.6 5.5 0.6 7.2 4.2 153 0 154 165 0.7 0 0.9 0.4 04/20/2007 05:00:00 6.1 0.6 7.6 3.8 5.8 0.6 7.2 4.2 5.1 0.7 6.8 2.6 153 0 154 165 0.7 0 0.9 0.7 04/20/2007 05:10:00 6.4 0.6 8.4 4.6 6.2 0.7 8.4 4.2 5.6 0.7 7.6 3.4 153 0 154 165 0.7 0 0.9 0.7 04/20/2007 05:20:00 6.6 0.5 8.4 5.3 6.5 0.6 8 4.9 6 0.6 7.6 4.6 153 0 154 165 0.7 0 0.9 0.7 04/20/2007 05:30:00 6.9 0.5 8.4 5.7 7.1 0.5 8.8 5.7 6.2 0.6 7.6 4.6 153 0 154 165 0.7 0 0.9 0.7 04/20/2007 05:40:00 6.8 0.6 8.4 4.9 6.9 0.7 8.8 5.3 6.1 0.7 7.6 4.2 153 0 154 165 0.8 0 0.9 0.7 04/20/2007 05:50:00 7.2 0.7 8.8 5.3 7.3 0.6 9.1 5.7 6.3 0.7 8 4.6 153 0 154 165 0.8 0 0.9 0.7 04/20/2007 06:00:00 7.7 0.7 9.9 5.3 7.6 0.7 9.9 5.3 6.6 0.6 8.4 4.6 153 0 154 165 0.8 0 0.9 0.7 04/20/2007 06:10:00 7.2 0.5 8.8 5.7 7.1 0.5 8.4 5.7 6.1 0.5 7.2 4.6 154 0 154 165 0.8 0 0.9 0.9 04/20/2007 06:20:00 7.4 0.7 9.1 5.7 7.3 0.6 9.5 5.7 6.5 0.6 8.4 4.9 154 0 154 165 0.8 0 1.1 0.9 04/20/2007 06:30:00 6.5 0.6 8 4.9 6.5 0.5 8 4.9 5.5 0.6 7.2 4.6 154 0 154 165 0.8 0 1.1 0.9 04/20/2007 06:40:00 6.6 0.8 8.4 3.8 6.7 0.8 8.4 3.8 5.5 0.9 7.2 3.4 154 0 154 165 0.8 0 0.9 0.7 04/20/2007 06:50:00 7.2 0.8 8.8 4.9 7.1 0.7 9.1 4.9 6.1 0.8 8.8 4.2 154 0 154 165 0.9 0 1.1 0.9 04/20/2007 07:00:00 7.3 0.9 9.5 3.8 7.1 0.8 9.1 4.2 6.1 0.8 8 3.8 154 0 154 165 1 0 1.4 0.9 04/20/2007 07:10:00 6.7 1 8.8 3.8 6.5 0.8 8.8 4.2 5.7 0.8 7.6 3.8 154 0 154 165 1.1 0 1.4 0.9 04/20/2007 07:20:00 6.3 0.8 8.4 4.2 6 0.6 7.6 4.2 5.4 0.7 7.2 3.8 154 0 154 165 1.2 0 1.4 0.9 04/20/2007 07:30:00 5.5 0.9 8.4 3.8 5.6 0.8 8.4 3.8 5.2 0.6 7.6 3.8 154 0 154 165 1.3 0 1.4 1.1 04/20/2007 07:40:00 5.4 0.8 7.6 3 5.7 0.8 7.6 3.8 5 0.6 6.8 3.4 154 0 154 165 1.3 0 1.4 1.1 04/20/2007 07:50:00 6.1 0.7 8 3.8 6.4 0.8 8.4 3.8 5.7 0.8 8 3 154 0 154 165 1.4 0 1.6 1.1 04/20/2007 08:00:00 6.3 0.6 7.2 4.6 6.4 0.7 8 4.6 6.3 0.6 8 4.6 154 0 154 165 1.4 0 1.6 1.4 04/20/2007 08:10:00 6.1 0.5 7.6 4.9 6.1 0.6 8.4 4.2 6.1 0.6 8 4.6 154 0 154 165 1.5 0 1.6 1.4 04/20/2007 08:20:00 5.6 0.6 7.2 4.2 5.1 0.8 7.2 3.8 5.4 0.7 7.2 4.2 154 0 154 165 1.5 0 1.6 1.4 04/20/2007 08:30:00 4.9 0.5 6.5 3.4 4 0.3 4.6 3.4 4.2 0.5 5.7 2.6 154 0 154 165 1.5 0 1.6 1.4 04/20/2007 08:40:00 5 0.6 6.1 3.4 4 0.3 4.6 3 4.7 0.7 6.5 3.4 154 0 154 165 1.6 0 1.6 1.4 04/20/2007 08:50:00 5.4 0.7 7.2 3.4 4.2 0.6 6.5 3 4.9 0.8 7.2 3 154 0 154 165 1.6 0 1.8 1.4 04/20/2007 09:00:00 4.9 0.6 6.5 3.4 4.9 0.5 6.5 3.8 5.1 0.6 6.8 3 154 0 154 165 1.6 0 1.8 1.4 04/20/2007 09:10:00 4.8 0.5 6.1 3.8 4.9 0.5 6.1 3.8 5 0.5 6.5 3.4 154 0 154 165 1.6 0 1.8 1.4 04/20/2007 09:20:00 5.1 0.6 6.8 3.8 5.1 0.6 7.2 3.8 5.2 0.7 6.8 3.8 135 19 154 165 1.6 0 1.8 1.4 04/20/2007 09:30:00 4.7 0.7 7.2 3 4.9 0.7 6.8 3.4 5 0.6 7.6 3.4 111 7 119 165 1.6 0 1.8 1.4 04/20/2007 09:40:00 5.1 0.6 6.8 3.8 5.3 0.6 6.8 4.2 5.3 0.5 6.8 4.2 116 5 104 165 1.6 0 1.8 1.4 04/20/2007 09:50:00 5.3 0.6 6.8 3.8 5.4 0.6 6.8 3.8 5.4 0.6 6.8 3.8 117 6 115 165 1.6 0 1.6 1.6 04/20/2007 10:00:00 4.9 0.6 6.5 3.4 4.9 0.6 6.5 3.8 5.1 0.6 6.5 3.4 114 6 113 165 1.6 0 1.6 1.4 04/20/2007 10:10:00 4.7 0.7 6.5 3.4 4.8 0.5 6.5 3.4 5 0.6 6.8 3.8 114 5 105 165 1.6 0 1.8 1.4 04/20/2007 10:20:00 4.8 0.5 6.1 3.8 5.3 0.6 7.2 3.8 5.6 0.6 7.6 4.2 122 6 121 165 1.6 0 1.8 1.4 04/20/2007 10:30:00 4.6 0.4 5.3 3.4 5.3 0.6 6.5 3.4 5.6 0.6 6.8 3.8 124 6 123 165 1.6 0 1.6 1.4 04/20/2007 10:40:00 5.1 0.5 6.1 3.8 4.9 0.7 6.5 3 5.5 0.8 6.8 3 129 6 126 165 1.6 0 1.8 1.6 04/20/2007 10:50:00 4.9 0.4 5.7 3.8 3.8 0.8 5.7 1.9 3.7 0.6 5.3 2.3 126 8 123 165 1.6 0 1.8 1.4 04/20/2007 11:00:00 4.5 0.4 5.7 3.4 3.1 0.6 4.6 1.1 3.2 0.5 4.6 1.5 126 7 124 165 1.6 0 1.8 1.4 04/20/2007 11:10:00 4 0.4 4.6 2.3 2.4 0.6 3.8 0.4 2.8 0.5 3.8 1.1 123 6 121 165 1.6 0 1.8 1.4 04/20/2007 11:20:00 3.7 0.4 4.6 2.6 2.6 0.5 4.6 1.5 2.6 0.4 4.2 1.1 124 6 119 165 1.6 0 1.8 1.6 04/20/2007 11:30:00 3.7 0.3 4.6 2.3 2.4 0.5 4.2 0.7 2.4 0.4 4.2 1.1 126 8 136 165 1.7 0 1.8 1.6 04/20/2007 11:40:00 3.1 0.4 4.2 1.9 2.1 0.5 3 0.4 2.4 0.5 3.8 1.1 128 7 140 165 1.7 0 1.8 1.6 04/20/2007 11:50:00 2.5 0.4 3.4 1.5 2 0.5 3 0.4 2.3 0.4 3 1.1 128 6 132 165 1.8 0 1.8 1.6 04/20/2007 12:00:00 1.1 1 3 0.4 1.5 0.5 2.6 0.4 1.9 0.4 3 0.4 131 5 134 165 1.7 0 1.8 1.6 04/20/2007 12:10:00 0.4 0 0.4 0.4 0.4 0.1 1.1 0.4 0.4 0.1 1.1 0.4 110 6 165 165 1.8 0 1.8 1.6 04/20/2007 12:20:00 0.4 0 0.4 0.4 0.4 0.3 1.9 0.4 0.6 0.6 2.6 0.4 114 6 165 165 1.8 0 1.8 1.6 04/20/2007 12:30:00 0.4 0 0.4 0.4 0.8 0.6 3 0.4 0.8 0.7 2.6 0.4 117 7 165 165 1.8 0 1.8 1.6 04/20/2007 12:40:00 0.4 0 0.4 0.4 0.9 0.7 3 0.4 0.4 0 0.7 0.4 118 7 165 165 1.8 0 1.8 1.6 04/20/2007 12:50:00 0.4 0 0.7 0.4 0.6 0.5 2.3 0.4 0.4 0 0.7 0.4 118 6 111 165 1.8 0 1.8 1.6 04/20/2007 13:00:00 0.4 0 0.4 0.4 0.4 0 0.7 0.4 0.4 0 0.4 0.4 122 5 165 165 1.8 0 1.8 1.6 04/20/2007 13:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 116 6 165 165 1.8 0 1.8 1.6 04/20/2007 13:20:00 0.4 0 0.4 0.4 0.4 0 0.7 0.4 0.4 0 0.7 0.4 118 6 165 165 1.8 0 1.8 1.6 04/20/2007 13:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.7 0.4 121 8 165 165 1.8 0 1.8 1.6 04/20/2007 13:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 119 6 165 165 1.8 0 1.8 1.8 04/20/2007 13:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 115 7 165 165 1.9 0 2.1 1.8 04/20/2007 14:00:00 1.6 3.1 10.7 0.4 0.4 0 0.4 0.4 1.4 2.7 9.9 0.4 117 6 125 165 1.9 0 2.1 1.8 04/20/2007 14:10:00 9.9 1.3 13.3 5.7 0.4 0 0.4 0.4 8.7 1.5 12.6 5.3 116 7 102 165 2 0 2.3 1.8 04/20/2007 14:20:00 13.3 1.9 17.9 8.4 9.3 6.7 18.3 0.4 12.4 2.3 17.9 7.2 115 6 116 165 2.2 0 2.3 2.1 04/20/2007 14:30:00 13.2 1.5 17.6 9.1 13.4 1.5 17.9 9.1 12.6 1.7 18.3 7.6 116 7 99 165 2.2 0 2.3 2.1 04/20/2007 14:40:00 14.6 1.9 19.5 8.4 14.9 2 19.9 8.8 13.9 2.1 19.5 8.4 111 7 110 165 2.1 0 2.3 1.8 04/20/2007 14:50:00 14.8 1.5 18.7 10.7 15.1 1.5 18.7 10.7 14 1.7 18.3 9.5 111 6 109 165 2.3 0 2.3 2.1 04/20/2007 15:00:00 14.1 2.3 18.7 8.8 14.4 2.4 18.7 8.8 13.3 2.4 19.1 8 112 6 107 165 2.3 0 2.6 2.1 04/20/2007 15:10:00 14.7 1.6 18.3 9.5 15 1.6 18.7 9.5 14.3 1.6 18.3 9.9 112 6 109 165 2.2 0 2.6 1.8 04/20/2007 15:20:00 14.7 1.5 17.9 8.8 15 1.6 18.7 8.8 13.9 1.7 17.6 8.8 112 6 116 165 2.3 0 2.6 2.1 04/20/2007 15:30:00 14.2 1.5 17.9 9.5 14.5 1.5 18.7 9.9 13.3 1.8 18.7 8 108 6 105 165 2.3 0 2.6 2.3 04/20/2007 15:40:00 13.8 1.8 17.9 8 14.1 1.8 18.3 8.8 13.1 2 17.9 8.4 110 6 113 165 2.3 0 2.6 2.3 04/20/2007 15:50:00 15.6 1.2 18.7 11.1 15.8 1.3 19.1 11.5 14.8 1.5 17.9 10.7 108 5 107 165 2.3 0 2.6 2.1 04/20/2007 16:00:00 14.3 1.7 17.6 9.9 14.7 1.7 17.9 9.9 13.8 1.8 17.9 8 107 7 114 165 2.3 0 2.6 2.1 04/20/2007 16:10:00 14.5 1.3 17.6 10.7 14.8 1.4 17.9 10.7 13.9 1.6 17.2 9.1 108 5 105 165 2.2 0 2.3 2.1 04/20/2007 16:20:00 14.4 1.9 18.7 9.5 14.7 1.9 18.7 9.5 13.9 2.1 18.7 9.5 106 5 107 165 2.2 0 2.6 2.1 04/20/2007 16:30:00 13.9 1.9 17.9 7.6 14.2 2 18.3 7.2 13.3 2.1 17.6 8.4 106 6 101 165 2.2 0 2.3 2.1 04/20/2007 16:40:00 13.4 2.3 17.9 8.4 13.6 2.3 17.9 8.4 12.7 2.3 17.9 7.6 109 6 104 165 2.3 0 2.6 2.1 04/20/2007 16:50:00 13.4 1.2 16.4 9.1 13.7 1.2 16.8 9.5 12.6 1.5 16.1 8 107 5 105 165 2.3 0 2.6 2.3 04/20/2007 17:00:00 14.5 1.7 17.6 9.9 14.8 1.7 17.9 10.3 13.8 2.1 17.6 8.4 107 5 106 165 2.3 0 2.6 2.1 04/20/2007 17:10:00 14.6 1.6 17.6 9.1 14.8 1.6 17.9 9.1 13.6 1.8 17.6 8 109 6 107 165 2.3 0 2.6 2.1 04/20/2007 17:20:00 13.8 1.5 17.2 7.6 14 1.5 17.6 7.6 13 1.5 16.8 8.8 108 6 103 165 2.3 0 2.6 2.1 04/20/2007 17:30:00 13.1 1.3 16.8 9.1 13.4 1.4 16.8 9.1 12.4 1.5 16.4 8.4 108 7 110 165 2.4 0 2.6 2.3 04/20/2007 17:40:00 14.4 1.3 17.9 9.9 14.7 1.3 18.3 9.9 13.7 1.5 17.6 8.8 108 5 99 165 2.4 0 2.6 2.3 04/20/2007 17:50:00 13 2.2 17.6 7.2 13.3 2.2 17.6 7.2 12.3 2.3 16.8 7.2 109 6 107 165 2.4 0 2.6 2.3 04/20/2007 18:00:00 13.6 2.1 17.2 6.5 13.9 2.2 17.6 6.8 12.9 2.1 17.2 7.2 107 6 106 165 2.4 0 2.8 2.3 04/20/2007 18:10:00 12.9 1.6 17.2 8.8 13.2 1.6 17.6 8.8 12.3 1.7 16.1 8 107 6 98 165 2.4 0 2.8 2.3 04/20/2007 18:20:00 13.1 1.6 16.4 9.1 13.4 1.6 16.8 9.1 12.4 1.6 16.4 8.4 108 6 106 165 2.5 0 2.8 2.3 04/20/2007 18:30:00 12.9 1.5 16.4 8.4 13.2 1.6 16.4 8.8 12.2 1.7 16.1 7.6 105 6 106 165 2.5 0 2.8 2.3 04/20/2007 18:40:00 12.8 1.4 16.1 8 13 1.4 16.1 8.8 12.1 1.5 15.6 8 108 8 114 165 2.5 0 2.8 2.3 04/20/2007 18:50:00 12.7 1.3 16.1 9.5 13 1.3 16.4 9.5 12.1 1.5 16.1 8 103 6 102 165 2.5 0 2.8 2.3 04/20/2007 19:00:00 12.8 1.5 16.8 8.8 13.1 1.5 17.6 8.4 12.3 1.5 16.1 8.4 105 7 104 165 2.6 0 2.8 2.6 04/20/2007 19:10:00 14.1 1.5 17.2 9.9 14.3 1.5 17.6 10.3 13.4 1.6 16.8 9.9 106 6 102 165 2.6 0 2.8 2.6 04/20/2007 19:20:00 14 1.9 18.7 9.5 14.3 1.9 19.1 9.5 13.2 2.1 18.3 8.8 106 7 101 165 2.6 0 2.8 2.6 04/20/2007 19:30:00 13 1.7 16.8 8.8 13.3 1.8 17.2 9.1 12.4 1.7 16.4 8 106 6 111 165 2.6 0 2.8 2.6 04/20/2007 19:40:00 14 1.4 16.8 9.5 14.4 1.4 17.2 10.3 13.3 1.7 16.8 8.4 107 7 107 165 2.6 0 2.8 2.6 04/20/2007 19:50:00 13.9 1.6 17.6 7.6 14.2 1.7 17.9 8 13.1 1.7 16.8 8 105 7 112 165 2.6 0 2.8 2.6 04/20/2007 20:00:00 13.3 1.4 17.2 9.5 13.6 1.4 17.9 9.9 12.7 1.6 16.4 8.8 107 6 104 165 2.6 0 2.8 2.6 04/20/2007 20:10:00 14.1 1.6 17.9 9.1 14.5 1.6 18.3 9.5 13.4 1.6 17.2 9.9 106 5 105 165 2.6 0 2.8 2.6 04/20/2007 20:20:00 14.1 1.4 17.9 10.3 14.4 1.4 18.3 10.7 13.4 1.6 17.2 9.1 105 6 102 165 2.6 0 2.8 2.6 04/20/2007 20:30:00 14.4 1.5 18.3 9.1 14.7 1.5 18.7 9.9 13.7 1.6 16.8 8.4 106 6 102 165 2.7 0 2.8 2.6 04/20/2007 20:40:00 14.7 1.2 18.3 11.8 15 1.3 18.3 11.1 13.9 1.5 17.6 9.9 107 5 112 165 2.7 0 2.8 2.6 04/20/2007 20:50:00 13.4 1.8 17.2 9.1 13.8 1.8 17.6 9.5 12.9 2 17.6 8 106 7 110 165 2.7 0 2.8 2.6 04/20/2007 21:00:00 14.3 1.6 17.2 9.9 14.5 1.6 17.9 9.9 13.5 1.7 16.8 9.1 106 7 105 165 2.6 0 2.8 2.6 04/20/2007 21:10:00 13.8 1.6 18.3 8.8 14.1 1.6 17.9 8.8 13 1.6 17.6 8.4 103 6 105 165 2.7 0 2.8 2.6 04/20/2007 21:20:00 14.6 1.3 17.9 10.7 14.9 1.3 17.9 10.7 13.8 1.5 17.6 9.9 102 6 101 165 2.7 0 2.8 2.6 04/20/2007 21:30:00 14.1 1.5 17.9 9.5 14.5 1.5 18.7 9.9 13.6 1.5 17.9 9.5 100 7 109 165 2.7 0 2.8 2.6 04/20/2007 21:40:00 14.3 1.5 17.6 9.9 14.6 1.5 17.6 10.3 13.4 1.6 17.2 9.1 101 6 99 165 2.7 0 2.8 2.6 04/20/2007 21:50:00 14.8 1.3 18.7 11.5 15.1 1.3 19.5 11.5 13.9 1.3 17.6 10.7 101 6 96 165 2.7 0 2.8 2.6 04/20/2007 22:00:00 14.5 1.5 18.7 11.1 14.9 1.5 19.1 11.5 13.9 1.7 19.1 9.9 98 6 102 165 2.7 0 3 2.6 04/20/2007 22:10:00 14.8 1.4 17.9 10.7 15.1 1.4 18.3 10.7 14.1 1.4 17.6 8.8 96 5 92 165 2.8 0 3 2.6 04/20/2007 22:20:00 15 1.4 18.7 11.1 15.3 1.3 19.1 10.7 14.2 1.5 18.3 10.3 98 6 110 165 2.8 0 3 2.6 04/20/2007 22:30:00 13.4 1.7 17.6 9.1 13.8 1.7 17.6 9.1 12.8 1.6 16.8 8.4 100 8 96 165 2.8 0 3 2.6 04/20/2007 22:40:00 14.6 1.6 17.6 9.9 14.9 1.6 17.6 10.3 13.8 1.6 17.6 9.5 97 7 102 165 2.9 0 3 2.6 04/20/2007 22:50:00 14.9 1.5 18.3 9.9 15.2 1.5 18.3 9.9 14 1.5 17.6 9.9 98 6 100 165 2.9 0 3 2.8 04/20/2007 23:00:00 14.8 1.2 17.6 11.1 15.2 1.2 17.9 11.5 14.1 1.4 17.9 10.3 99 5 99 165 2.9 0 3 2.8 04/20/2007 23:10:00 14.9 1.3 17.9 11.5 15.2 1.3 18.3 11.5 14 1.6 18.7 9.9 99 5 100 165 3 0 3.3 2.8 04/20/2007 23:20:00 14.3 1.2 16.8 10.3 14.6 1.2 17.2 10.3 13.4 1.2 16.4 9.1 98 6 94 165 3 0 3.3 2.8 04/20/2007 23:30:00 14.7 1.3 19.1 10.3 15.1 1.3 19.1 10.7 13.8 1.5 18.3 9.9 98 5 99 165 3 0 3.3 2.8 04/20/2007 23:40:00 15 1.3 18.3 9.5 15.3 1.3 18.7 9.9 14.2 1.4 17.2 9.9 100 6 89 165 3 0 3.3 2.8 04/20/2007 23:50:00 14.9 1.5 18.7 10.7 15.3 1.5 19.1 10.7 14.1 1.5 17.9 10.3 100 6 93 165 3 0 3.3 2.8 04/21/2007 00:00:00 14.9 1.3 17.9 10.7 15.3 1.3 18.3 11.5 14 1.5 17.6 9.1 100 6 97 165 3 0 3.3 2.8 04/21/2007 00:10:00 14.9 1.6 18.7 9.9 15.2 1.6 19.1 10.3 14 1.6 17.9 9.5 100 7 99 165 3 0 3.3 2.8 04/21/2007 00:20:00 14.2 1.5 18.3 9.1 14.6 1.5 18.3 9.5 13.4 1.6 17.2 8.4 100 5 104 165 3 0 3.3 3 04/21/2007 00:30:00 14.4 1.2 18.7 10.7 14.8 1.2 19.1 11.1 13.5 1.4 17.6 9.5 98 6 99 165 3 0 3.3 2.8 04/21/2007 00:40:00 13.9 1.2 17.2 9.9 14.3 1.2 17.2 10.3 13.1 1.3 16.4 9.5 99 6 92 165 3 0 3.3 2.8 04/21/2007 00:50:00 14.3 1.2 17.6 9.9 14.6 1.2 17.9 10.7 13.4 1.5 17.2 9.9 95 6 88 165 3 0 3.3 2.8 04/21/2007 01:00:00 13.9 1.5 17.2 9.5 14.3 1.5 17.6 10.3 13.1 1.6 16.4 8.8 98 8 88 165 3 0 3.3 2.8 04/21/2007 01:10:00 13.7 1.3 17.2 9.9 14.1 1.3 17.9 10.3 13.1 1.5 17.2 9.9 101 6 92 165 2.9 0 3 2.8 04/21/2007 01:20:00 13.4 1.2 16.4 8.8 13.7 1.3 16.4 8.8 12.7 1.4 16.1 8 102 6 105 165 3 0 3.3 2.8 04/21/2007 01:30:00 14.1 1.3 17.6 10.3 14.5 1.3 17.9 10.3 13.4 1.5 17.2 9.1 96 6 98 165 3 0 3.3 2.8 04/21/2007 01:40:00 13.7 1 16.4 9.9 14.1 1.1 16.8 10.7 12.9 1.2 16.4 9.5 98 6 96 165 3 0 3.3 2.8 04/21/2007 01:50:00 13.9 1.3 18.3 9.9 14.2 1.3 18.7 9.9 13.3 1.3 17.2 9.5 99 6 94 165 3 0 3.3 2.8 04/21/2007 02:00:00 14.9 1.2 18.3 11.1 15.3 1.2 18.3 11.5 14.1 1.3 17.6 10.3 99 5 102 165 3 0 3.3 2.8 04/21/2007 02:10:00 14.8 1.2 19.1 9.9 15.2 1.2 19.5 9.9 14.1 1.4 18.7 8.8 99 6 99 165 3 0 3.3 2.8 04/21/2007 02:20:00 13.9 1.3 17.2 10.3 14.2 1.3 17.2 10.7 13.1 1.4 16.4 8.8 101 6 107 165 3 0 3.3 2.8 04/21/2007 02:30:00 14.1 1.4 17.6 9.9 14.5 1.4 17.6 10.3 13.2 1.4 16.4 8.8 96 6 92 165 3 0 3 2.8 04/21/2007 02:40:00 14.8 1.3 18.3 10.3 15.2 1.3 18.7 11.1 13.8 1.5 17.9 10.3 94 6 106 165 3 0 3.3 2.8 04/21/2007 02:50:00 16.4 1.1 19.1 13 16.8 1.1 19.5 13.3 15.6 1.3 18.7 11.5 91 5 97 165 3 0 3 2.8 04/21/2007 03:00:00 15.2 1.5 18.3 10.7 15.6 1.6 18.7 11.1 14.5 1.6 17.9 10.7 92 5 90 165 2.9 0 3 2.8 04/21/2007 03:10:00 14.4 1.5 17.6 9.5 14.8 1.5 18.3 9.5 13.7 1.6 17.6 9.1 95 6 97 165 2.9 0 3 2.8 04/21/2007 03:20:00 13.9 1.9 17.6 8 14.3 1.9 17.6 8.4 13.2 1.8 17.2 8 92 7 104 165 2.9 0 3 2.8 04/21/2007 03:30:00 15.4 1.7 18.7 10.7 15.8 1.7 19.1 10.7 14.7 1.7 18.3 9.9 91 5 89 165 2.9 0 3 2.8 04/21/2007 03:40:00 15.9 1.4 19.1 11.8 16.3 1.3 19.9 12.6 15.3 1.3 18.3 11.5 89 5 94 165 2.9 0 3 2.8 04/21/2007 03:50:00 16.6 1.2 19.5 12.2 17 1.2 19.9 12.6 16.1 1.3 19.1 11.8 90 4 91 165 2.9 0 3 2.8 04/21/2007 04:00:00 14.8 1.1 18.3 10.3 15.2 1.2 18.7 9.9 14.4 1.2 17.6 11.1 90 5 85 165 3 0 3.3 2.8 04/21/2007 04:10:00 15.3 1.1 17.9 11.1 15.7 1.2 18.3 11.1 14.8 1.3 17.9 11.1 91 4 90 165 2.9 0 3 2.8 04/21/2007 04:20:00 15.5 0.9 17.6 12.2 15.9 0.9 17.9 12.6 15 1 17.2 12.2 87 4 84 165 2.9 0 3 2.8 04/21/2007 04:30:00 14.8 1.5 18.7 10.7 15.2 1.5 19.1 11.1 14.4 1.5 17.9 10.7 91 6 84 165 2.9 0 3.3 2.8 04/21/2007 04:40:00 14.7 1.4 17.6 11.1 15.1 1.4 17.9 11.5 14.1 1.5 17.2 9.5 92 5 100 165 2.9 0 3.3 2.8 04/21/2007 04:50:00 14.8 1.2 18.3 11.8 15.2 1.2 18.7 11.8 14.3 1.3 17.9 10.7 90 5 94 165 3 0 3.3 2.8 04/21/2007 05:00:00 14.6 1.3 19.5 10.7 15.1 1.3 19.5 11.1 14.3 1.3 18.3 10.7 89 6 87 165 3 0 3.3 2.8 04/21/2007 05:10:00 15.6 1.3 17.9 11.1 16 1.3 18.7 11.8 15.1 1.4 17.9 10.3 88 5 89 165 3 0 3.3 2.8 04/21/2007 05:20:00 15.8 1.2 18.3 11.1 16.2 1.2 18.7 11.8 15.2 1.2 17.9 11.8 90 4 91 165 3 0 3 2.8 04/21/2007 05:30:00 15.1 1.5 18.3 9.5 15.4 1.5 18.3 9.9 14.3 1.6 17.9 8.8 92 5 89 165 2.9 0 3 2.8 04/21/2007 05:40:00 14.9 1.3 17.6 11.1 15.3 1.3 17.9 11.8 13.9 1.5 17.2 10.3 99 5 99 165 2.8 0 3 2.6 04/21/2007 05:50:00 13.4 1.3 16.8 9.1 13.7 1.3 17.2 9.9 12.7 1.4 16.1 9.1 100 5 97 165 2.9 0 3 2.8 04/21/2007 06:00:00 11.9 2 17.2 8.4 12.3 2 17.6 8.8 11.3 2 16.4 7.6 98 8 94 165 2.9 0 3 2.6 04/21/2007 06:10:00 13.4 1.3 16.8 9.1 13.7 1.3 17.2 9.5 12.7 1.4 16.1 9.1 99 7 96 165 2.8 0 3 2.6 04/21/2007 06:20:00 13.7 1.5 18.3 9.5 14.1 1.5 18.7 9.1 12.9 1.7 17.2 8.8 97 6 92 165 2.7 0 3 2.6 04/21/2007 06:30:00 14.1 1.4 17.2 9.9 14.4 1.5 17.6 9.9 13.1 1.5 16.8 8.4 97 6 96 165 2.7 0 3 2.6 04/21/2007 06:40:00 13.8 1.8 17.6 9.5 14.1 1.9 17.9 9.9 13 2 17.9 8.4 93 7 80 165 2.9 0 3 2.3 04/21/2007 06:50:00 15.1 1.4 18.3 10.7 15.5 1.4 18.7 10.7 14.2 1.5 17.2 9.9 95 7 94 165 2.9 0 3 2.8 04/21/2007 07:00:00 12.7 2.1 17.9 7.6 13 2.1 17.2 8 11.9 2.1 16.4 7.2 102 7 96 165 2.9 0 3 2.3 04/21/2007 07:10:00 13.1 1.6 17.6 9.1 13.5 1.6 17.9 9.5 12.6 1.6 16.4 8 99 8 94 165 2.9 0 3 2.3 04/21/2007 07:20:00 13.6 1.6 16.8 9.1 14 1.6 17.6 9.9 12.9 1.7 16.8 8.8 99 6 89 165 2.8 0 3 2.6 04/21/2007 07:30:00 14.2 1.6 18.7 10.3 14.5 1.6 19.1 10.3 13.3 1.8 17.9 9.1 99 6 107 165 2.8 0 3 2.6 04/21/2007 07:40:00 13.4 1.4 16.8 9.1 13.8 1.4 17.2 9.5 13 1.5 16.8 8.8 98 6 98 165 2.8 0 3 2.6 04/21/2007 07:50:00 14 1.2 16.4 10.7 14.3 1.2 17.2 10.3 13.2 1.3 16.4 9.5 98 6 99 165 2.8 0 3 2.6 04/21/2007 08:00:00 13.4 1.3 16.8 8.8 13.8 1.3 17.6 10.3 12.8 1.4 16.1 8.8 97 7 108 165 2.9 0 3 2.8 04/21/2007 08:10:00 13.5 1.7 17.9 9.1 13.8 1.7 18.3 9.5 12.8 1.7 16.8 9.1 99 7 102 165 2.9 0 3 2.8 04/21/2007 08:20:00 13.1 1.7 16.8 8.8 13.5 1.6 16.8 8.4 12.5 1.6 16.4 7.6 103 7 111 165 2.9 0 3 2.8 04/21/2007 08:30:00 13.1 1.5 16.8 9.1 13.4 1.5 17.2 9.5 12.4 1.5 16.8 8.4 102 7 99 165 2.9 0 3 2.8 04/21/2007 08:40:00 13.7 1.4 17.2 9.9 14 1.4 17.6 9.9 13.1 1.6 17.6 9.1 108 6 115 165 2.7 0 3 2.6 04/21/2007 08:50:00 13 1.8 16.8 7.6 13.3 1.8 17.6 8 12.3 1.9 16.8 8 106 7 108 165 2.7 0 3 2.6 04/21/2007 09:00:00 12.6 1.9 17.6 8.4 12.9 1.9 17.9 8 11.8 1.9 17.6 8 104 8 86 165 2.7 0 2.8 2.6 04/21/2007 09:10:00 12.8 1.9 17.2 6.5 13.1 1.9 17.6 7.6 12.1 2 16.8 7.6 104 8 107 165 2.7 0 2.8 2.6 04/21/2007 09:20:00 12.6 1.7 16.1 7.6 12.9 1.7 16.4 8 11.9 1.8 16.1 7.2 104 7 102 165 2.7 0 3 2.6 04/21/2007 09:30:00 13.1 1.3 16.1 9.1 13.4 1.3 16.4 9.9 12.3 1.5 16.4 8.4 103 6 99 165 2.7 0 2.8 2.6 04/21/2007 09:40:00 13.6 1.4 16.8 9.5 13.9 1.4 17.2 9.9 12.7 1.5 17.2 8.4 103 7 98 165 2.7 0 2.8 2.6 04/21/2007 09:50:00 13.7 1.5 17.2 9.1 14 1.6 17.9 9.1 13 1.7 17.6 8.4 103 6 110 165 2.7 0 3 2.3 04/21/2007 10:00:00 13.7 1.3 17.2 9.9 14 1.3 17.6 9.9 12.9 1.3 16.1 9.1 103 7 107 165 2.9 0 3 2.3 04/21/2007 10:10:00 13.7 1.4 17.6 9.1 14 1.4 17.6 9.5 12.9 1.5 16.8 8.8 104 7 102 165 2.9 0 3 2.3 04/21/2007 10:20:00 13 1.7 16.8 8.8 13.2 1.7 17.2 8.8 12.2 1.7 15.6 8 108 7 113 165 3 0.1 3.3 2.6 04/21/2007 10:30:00 13.5 1.3 17.6 9.1 13.7 1.3 17.9 9.5 12.6 1.5 16.1 8.4 108 6 106 165 3 0 3.3 2.6 04/21/2007 10:40:00 13.6 1.6 17.6 8.4 13.9 1.6 17.6 8.8 13 1.7 16.8 8.4 109 6 110 165 3 0 3.3 2.6 04/21/2007 10:50:00 13.2 1.4 16.4 8 13.5 1.5 17.2 8.8 12.5 1.5 16.1 7.6 108 6 110 165 3.1 0 3.3 2.6 04/21/2007 11:00:00 13.1 1.5 17.9 9.1 13.4 1.6 17.9 9.5 12.4 1.6 17.9 8 107 7 99 165 3.2 0 3.3 2.8 04/21/2007 11:10:00 13.9 1.2 17.2 10.3 14.2 1.2 17.2 10.7 13.2 1.4 16.8 9.1 105 5 111 165 3.2 0 3.5 2.8 04/21/2007 11:20:00 14.1 1.4 17.9 10.3 14.4 1.4 19.1 10.3 13.4 1.4 18.3 9.1 108 6 104 165 3.2 0 3.5 2.8 04/21/2007 11:30:00 13.8 1.5 17.2 8.8 14.1 1.5 17.2 9.5 12.9 1.6 16.4 8.8 108 6 102 165 3.2 0 3.5 2.8 04/21/2007 11:40:00 14.3 1.5 18.7 10.7 14.5 1.5 19.1 10.7 13.5 1.8 18.7 9.1 110 6 114 165 3.2 0 3.5 2.8 04/21/2007 11:50:00 14.3 1.3 17.9 9.5 14.6 1.3 17.9 9.9 13.6 1.5 16.8 8.8 114 7 102 165 3.3 0 3.5 2.8 04/21/2007 12:00:00 13.3 1.7 17.6 8.8 13.5 1.7 17.9 9.1 12.6 1.7 17.2 8 116 8 119 165 3.3 0 3.5 2.8 04/21/2007 12:10:00 14.2 1.3 18.3 9.9 14.4 1.3 18.7 10.3 13.6 1.5 19.1 9.1 118 7 132 165 3.3 0 3.5 3.3 04/21/2007 12:20:00 13.3 1.5 17.2 9.5 13.5 1.5 17.2 9.9 12.7 1.5 16.8 9.1 119 7 111 165 3.3 0 3.5 3.3 04/21/2007 12:30:00 13.7 1.5 17.9 8.8 13.8 1.5 17.6 8 13.1 1.5 17.6 9.1 122 7 128 165 3.3 0 3.5 3.3 04/21/2007 12:40:00 14.4 2.2 20.2 7.6 14.5 2.2 20.2 8 13.8 2.2 19.1 8 119 7 126 165 3.4 0 3.5 3.3 04/21/2007 12:50:00 12.5 2.1 18.7 7.6 12.7 2.2 19.5 8 12 2.1 18.3 8 121 8 116 165 3.5 0 3.5 3.3 04/21/2007 13:00:00 12.9 1.5 16.8 8.8 13 1.5 17.2 8.4 12.1 1.5 16.4 6.8 118 7 119 165 3.5 0 3.5 3.3 04/21/2007 13:10:00 13.5 1.7 18.7 9.1 13.7 1.7 19.5 9.1 12.8 1.7 18.3 8.8 115 7 115 165 3.5 0 3.5 3.3 04/21/2007 13:20:00 14 1.3 16.8 9.1 14.2 1.3 17.6 9.9 13.2 1.5 17.6 8.8 115 8 113 165 3.5 0 3.5 3.3 04/21/2007 13:30:00 14 1.5 17.6 8.8 14.2 1.5 17.9 8.8 13.4 1.7 17.2 8.8 117 6 116 165 3.5 0 3.5 3.3 04/21/2007 13:40:00 14.3 1.3 17.9 9.9 14.5 1.4 18.3 9.5 13.6 1.5 17.9 9.9 118 7 110 165 3.5 0 3.5 3.5 04/21/2007 13:50:00 13.6 1.5 17.6 9.1 13.7 1.5 17.6 9.1 12.8 1.7 17.2 8.8 118 7 115 165 3.5 0 3.5 3.5 04/21/2007 14:00:00 14.8 1.5 18.3 10.7 14.9 1.5 18.7 11.1 14.3 1.6 18.7 10.3 121 6 115 165 3.5 0 3.8 3.5 04/21/2007 14:10:00 14.4 1.6 18.3 10.7 14.6 1.6 19.1 11.1 14 1.7 18.7 8.8 123 7 121 165 3.5 0 3.8 3.5 04/21/2007 14:20:00 13.8 1.5 17.2 8.4 14 1.5 17.6 9.5 13.3 1.6 17.2 9.1 121 8 119 165 3.5 0 3.8 3.3 04/21/2007 14:30:00 14.7 1.5 19.1 10.3 14.8 1.5 19.1 9.9 14.3 1.5 18.3 9.9 119 7 119 165 3.5 0 3.8 3.3 04/21/2007 14:40:00 14.5 1.5 18.3 10.3 14.6 1.5 18.3 9.5 14 1.7 17.9 8.8 122 7 125 165 3.5 0 3.8 3.3 04/21/2007 14:50:00 14.3 1.2 17.9 11.1 14.4 1.2 17.9 11.5 13.9 1.5 18.7 9.5 121 6 122 165 3.5 0 3.8 3.3 04/21/2007 15:00:00 13.9 1.3 18.7 11.5 14 1.3 18.7 11.1 13.5 1.3 19.1 9.1 122 8 128 165 3.5 0 4 3.3 04/21/2007 15:10:00 14.6 1.3 18.3 11.5 14.7 1.3 18.3 11.8 14.2 1.3 17.6 9.9 126 7 122 165 3.5 0 3.8 3.3 04/21/2007 15:20:00 15 1.3 18.7 11.8 15 1.3 19.1 11.8 14.6 1.3 17.9 11.5 123 8 121 165 3.5 0 3.8 3.3 04/21/2007 15:30:00 15.6 1.6 19.5 10.7 15.6 1.5 19.5 10.7 15.2 1.7 19.5 11.5 124 8 118 165 3.5 0 3.8 3.3 04/21/2007 15:40:00 15.8 1.5 19.1 11.8 15.8 1.5 19.1 11.8 15.4 1.5 19.1 11.1 131 7 135 165 3.6 0 3.8 3.5 04/21/2007 15:50:00 15.7 1.7 19.9 11.8 15.7 1.7 19.9 11.5 15.2 1.7 19.9 11.1 132 7 122 165 3.5 0 3.8 3.3 04/21/2007 16:00:00 15.6 1.3 19.9 11.5 15.7 1.3 19.9 11.5 15.4 1.6 19.5 10.7 135 7 136 165 3.5 0 3.8 3.3 04/21/2007 16:10:00 15.2 1.1 18.3 12.2 15.3 1.1 18.3 12.6 15 1.3 17.9 11.1 129 6 134 165 3.5 0 3.5 3.3 04/21/2007 16:20:00 16 1.1 18.7 13.3 16 1.1 18.7 12.6 15.6 1.1 18.3 11.5 130 6 126 165 3.5 0 3.5 3.3 04/21/2007 16:30:00 15.2 1.4 18.7 11.5 15.2 1.4 18.7 11.8 14.6 1.5 18.7 9.1 131 8 130 165 3.5 0 3.5 3.3 04/21/2007 16:40:00 15.3 1.1 18.3 11.1 15.3 1.1 17.9 10.7 15.1 1.3 17.9 10.7 131 7 134 165 3.5 0 3.8 3.3 04/21/2007 16:50:00 15.6 2.1 20.6 10.7 15.7 2.2 20.6 11.1 15.4 2.3 20.6 9.9 129 8 129 165 3.5 0 3.5 3.3 04/21/2007 17:00:00 15.5 1.8 19.9 11.1 15.6 1.8 19.9 11.1 15 1.9 19.1 10.7 131 10 127 165 3.5 0 3.8 3 04/21/2007 17:10:00 15.1 1.3 17.9 10.3 15.1 1.4 18.3 9.5 14.7 1.4 18.7 9.5 130 6 127 165 3.5 0.1 3.8 3 04/21/2007 17:20:00 14.8 1.6 19.5 9.9 14.8 1.6 19.1 9.5 14.2 1.5 17.9 8.8 130 6 127 165 3.5 0.1 3.8 3 04/21/2007 17:30:00 14.3 1.5 18.7 10.7 14.4 1.5 19.1 10.7 14 1.6 18.7 9.9 127 6 128 165 3.5 0.1 3.8 3 04/21/2007 17:40:00 15 1.5 18.7 11.5 15.1 1.6 18.7 11.5 14.6 1.6 17.9 10.7 128 8 128 165 3.5 0.1 3.8 3 04/21/2007 17:50:00 14.5 1.5 17.9 9.9 14.6 1.5 17.9 9.9 14.1 1.7 18.7 8.8 124 8 129 165 3.5 0.1 3.8 3 04/21/2007 18:00:00 14.9 1.5 18.7 11.8 15 1.5 19.1 12.2 14.5 1.7 19.5 10.7 125 7 125 165 3.5 0.1 3.8 3 04/21/2007 18:10:00 14.5 1.3 18.3 10.7 14.6 1.3 18.7 11.1 14 1.2 17.9 10.7 127 7 116 165 3.5 0.1 3.8 3 04/21/2007 18:20:00 14.6 1.4 18.7 11.8 14.7 1.4 19.1 11.5 14.2 1.5 17.9 9.5 125 7 119 165 3.5 0.2 3.8 2.8 04/21/2007 18:30:00 14.8 1.4 19.5 11.8 14.9 1.3 19.9 12.2 14.5 1.4 18.7 11.5 127 7 125 165 3.5 0.1 3.8 3 04/21/2007 18:40:00 15.1 1.5 19.5 11.5 15.2 1.5 19.9 11.1 14.7 1.6 19.1 10.7 125 7 122 165 3.5 0.1 3.8 3 04/21/2007 18:50:00 14.3 1.4 18.3 10.7 14.4 1.4 18.7 10.7 13.8 1.5 18.7 10.3 124 7 119 165 3.5 0.2 3.8 3 04/21/2007 19:00:00 14.8 1.5 18.7 11.1 14.9 1.5 18.7 11.1 14.3 1.7 18.3 9.9 125 7 129 165 3.5 0.1 3.8 3 04/21/2007 19:10:00 15.1 1.3 18.3 12.2 15.3 1.3 19.1 12.2 14.8 1.4 19.5 9.9 121 6 117 165 3.5 0.2 3.5 3 04/21/2007 19:20:00 14.9 1.3 18.3 11.8 15.1 1.3 18.3 12.2 14.5 1.4 18.7 11.5 121 6 121 165 3.5 0.2 3.5 3 04/21/2007 19:30:00 14.9 1.4 17.9 10.3 15.1 1.4 18.3 11.1 14.5 1.5 17.6 9.9 122 8 116 165 3.5 0.2 3.8 3 04/21/2007 19:40:00 16.6 1.5 19.9 12.2 16.7 1.5 19.9 12.6 16.2 1.5 19.9 11.8 123 6 127 165 3.5 0.1 3.8 3 04/21/2007 19:50:00 16.4 1.5 21 12.6 16.6 1.6 21 12.6 16.1 1.6 21 11.1 123 6 122 165 3.5 0.2 3.8 3 04/21/2007 20:00:00 15.2 1.3 18.3 11.8 15.4 1.3 18.7 11.8 14.9 1.4 18.7 11.1 124 7 126 165 3.5 0.2 4.3 3 04/21/2007 20:10:00 16.5 1.7 20.2 12.2 16.7 1.7 20.2 13 16.2 1.7 20.6 11.5 123 6 126 165 3.5 0.2 3.8 3 04/21/2007 20:20:00 16.7 1.5 21 11.8 16.9 1.5 21 11.5 16.4 1.5 19.9 11.8 122 7 130 165 3.5 0.1 3.8 3 04/21/2007 20:30:00 16.7 1.5 20.6 12.2 16.9 1.5 21.4 12.6 16.4 1.7 21.4 11.8 120 6 111 165 3.5 0.1 3.8 3 04/21/2007 20:40:00 16.5 1.6 21 12.2 16.6 1.7 21.4 12.2 16.1 1.8 20.6 9.9 122 6 114 165 3.5 0.1 3.8 3 04/21/2007 20:50:00 16.3 1.3 19.9 13 16.4 1.3 20.2 12.6 15.8 1.3 19.5 12.2 124 5 121 165 3.5 0.1 3.8 3 04/21/2007 21:00:00 17.2 1.5 21 13.3 17.3 1.5 21 13.7 16.7 1.7 20.6 12.2 122 6 125 165 3.5 0.1 4.3 3 04/21/2007 21:10:00 15.8 1.4 19.1 11.8 16 1.4 19.9 12.2 15.5 1.4 19.5 10.7 124 7 118 165 3.5 0.1 3.8 3 04/21/2007 21:20:00 16.8 1.6 21 11.8 17 1.6 21.4 12.2 16.5 1.7 21.4 12.2 123 7 121 165 3.5 0.1 3.8 3.3 04/21/2007 21:30:00 17.1 2 21.8 11.8 17.3 2 22.1 11.8 16.7 2.1 21.8 11.5 123 6 119 165 3.5 0 3.8 3.3 04/21/2007 21:40:00 17.4 1.6 21.8 12.2 17.5 1.6 21.8 11.8 16.9 1.8 21.8 12.6 121 7 135 165 3.5 0.1 3.8 3.3 04/21/2007 21:50:00 16.6 1.8 22.1 11.5 16.8 1.8 22.1 11.8 16.1 2 21.4 11.5 121 8 122 165 3.5 0.1 3.8 3 04/21/2007 22:00:00 16.5 1.3 19.9 12.6 16.6 1.3 19.9 12.2 16 1.3 19.9 11.1 123 5 128 165 3.5 0.1 4 3.3 04/21/2007 22:10:00 17.1 1.9 21.8 12.6 17.2 1.9 22.6 12.2 16.7 2.2 22.1 10.3 123 7 124 165 3.5 0 3.8 3.3 04/21/2007 22:20:00 17.4 1.8 22.9 13.3 17.6 1.8 22.6 12.2 17.1 2 22.1 12.6 123 7 121 165 3.5 0 3.8 3.3 04/21/2007 22:30:00 17.2 1.5 20.6 13.7 17.4 1.6 21 13.7 16.6 1.7 21 12.2 123 6 111 165 3.5 0.1 3.8 3.3 04/21/2007 22:40:00 16.6 1.7 22.1 12.6 16.7 1.7 22.1 12.6 16.2 1.9 22.1 11.5 126 7 129 165 3.5 0.1 3.8 3.3 04/21/2007 22:50:00 16.6 1.5 19.9 12.6 16.8 1.6 19.9 12.2 16.1 1.6 20.6 11.8 123 6 123 165 3.5 0 3.8 3.3 04/21/2007 23:00:00 17.2 1.7 21.8 12.6 17.3 1.7 22.1 12.6 16.8 1.9 22.6 10.3 124 7 124 165 3.5 0.1 3.8 3.3 04/21/2007 23:10:00 16.9 1.3 21 13 17 1.3 21.4 13.7 16.4 1.6 20.6 11.8 127 6 123 165 3.5 0.1 3.8 3 04/21/2007 23:20:00 15.9 1.7 20.2 11.5 16.1 1.7 21 11.8 15.7 1.8 20.6 11.5 129 6 128 165 3.5 0 3.5 3 04/21/2007 23:30:00 16 1.4 19.9 11.8 16.1 1.4 19.5 11.8 15.8 1.5 19.5 11.8 128 7 135 165 3.5 0.1 3.8 3 04/21/2007 23:40:00 16.3 1.8 21.4 12.2 16.5 1.8 21 12.6 16.1 1.9 20.6 10.3 126 7 128 165 3.5 0.2 3.8 3 04/21/2007 23:50:00 15.4 1.4 19.1 12.2 15.5 1.4 19.5 12.2 15 1.5 18.7 9.5 126 6 109 165 3.4 0.1 3.5 3 04/22/2007 00:00:00 15.7 1.5 19.5 11.8 15.9 1.5 20.2 11.8 15.5 1.6 19.5 12.2 126 7 136 165 3.4 0.1 3.5 3 04/22/2007 00:10:00 15.1 1.7 19.9 10.3 15.2 1.7 19.9 9.5 14.6 1.8 20.2 9.5 124 7 129 165 3.4 0.1 3.5 3 04/22/2007 00:20:00 15.5 1.7 21 11.1 15.7 1.6 21 11.8 15.2 1.7 21.4 12.2 125 8 135 165 3.5 0.1 3.5 3 04/22/2007 00:30:00 16.4 1.5 20.2 12.6 16.5 1.5 20.2 13 16.2 1.5 20.2 12.6 127 6 128 165 3.5 0.1 3.8 3 04/22/2007 00:40:00 16 1.3 19.1 11.1 16.1 1.3 19.5 11.5 15.6 1.5 19.9 11.1 127 6 133 165 3.5 0.1 3.8 3 04/22/2007 00:50:00 16.4 1.4 19.9 13.3 16.5 1.4 20.6 13.3 16.1 1.4 20.2 12.2 124 6 117 165 3.5 0.1 3.8 3 04/22/2007 01:00:00 15.9 1.6 19.9 12.6 16.1 1.6 21 12.6 15.6 1.7 20.2 10.7 123 7 118 165 3.5 0.1 4 3 04/22/2007 01:10:00 16 2 19.9 11.5 16.2 2 20.2 12.2 15.6 2.1 20.2 10.7 123 6 118 165 3.5 0.1 3.8 3 04/22/2007 01:20:00 15.2 1.5 20.6 9.9 15.4 1.5 21 10.3 14.9 1.5 18.7 10.7 121 7 118 165 3.5 0.1 3.5 3 04/22/2007 01:30:00 14.4 1.6 18.3 10.7 14.5 1.6 18.7 10.7 13.8 1.5 17.9 9.5 121 7 126 165 3.5 0.1 3.8 3 04/22/2007 01:40:00 15 1.9 19.5 10.3 15.2 1.9 19.5 9.5 14.5 2 19.9 9.5 119 6 121 165 3.5 0.1 3.5 3 04/22/2007 01:50:00 14.6 1.5 19.1 11.1 14.8 1.5 19.1 11.1 14 1.7 17.9 9.5 120 6 119 165 3.5 0 3.8 3.3 04/22/2007 02:00:00 13.7 1.6 17.9 9.5 13.9 1.6 17.9 9.9 13.3 1.6 17.6 9.1 119 7 124 165 3.5 0 3.8 3.3 04/22/2007 02:10:00 13.3 1.7 17.9 8.8 13.4 1.7 17.9 8.4 12.4 1.8 17.6 7.6 116 7 112 165 3.5 0 3.5 3.3 04/22/2007 02:20:00 13.3 1.6 16.8 8.8 13.6 1.6 17.2 8.8 12.9 1.7 16.8 8.4 116 7 110 165 3.5 0 3.8 3.3 04/22/2007 02:30:00 13.5 1.5 17.2 9.1 13.7 1.6 17.6 9.1 13 1.5 16.1 8.4 113 7 105 165 3.5 0 3.8 3.3 04/22/2007 02:40:00 13.9 1.4 17.9 9.9 14.1 1.5 18.7 10.3 13.3 1.6 18.7 9.5 116 7 121 165 3.5 0 3.5 3 04/22/2007 02:50:00 13.7 1.5 17.2 8.8 13.9 1.5 17.9 9.1 13 1.7 17.6 7.2 117 7 108 165 3.5 0 3.8 3.3 04/22/2007 03:00:00 13.4 1.8 18.3 6.5 13.6 1.8 18.3 7.2 12.8 1.8 18.3 7.6 116 7 121 165 3.5 0 3.8 3.3 04/22/2007 03:10:00 14 1.5 17.9 9.9 14.2 1.5 18.7 9.9 13.1 1.6 16.8 9.1 114 7 115 165 3.5 0 3.5 3.3 04/22/2007 03:20:00 14.9 1.5 18.7 9.9 15.1 1.7 19.1 9.1 14 1.9 18.3 8.8 115 7 115 165 3.5 0 3.5 3 04/22/2007 03:30:00 15.1 1.6 19.5 11.1 15.3 1.6 19.9 10.7 14.5 1.9 19.9 9.5 116 6 114 165 3.5 0 3.5 3 04/22/2007 03:40:00 14.6 1.7 18.3 9.5 14.8 1.7 18.3 9.5 14 1.7 18.3 9.5 116 7 112 165 3.5 0 3.5 2.8 04/22/2007 03:50:00 14.8 1.7 19.5 9.9 15 1.7 20.2 10.3 14.1 1.7 18.3 9.5 119 6 122 165 3.5 0 3.5 2.8 04/22/2007 04:00:00 15.4 1.9 20.6 11.5 15.5 1.9 20.6 11.5 14.7 1.9 21 10.3 120 6 122 165 3.4 0 3.8 3 04/22/2007 04:10:00 15.1 1.5 19.9 10.7 15.2 1.5 20.2 11.1 14.4 1.7 19.1 9.9 122 7 123 165 3.3 0 3.5 3 04/22/2007 04:20:00 14.6 1.7 18.3 9.9 14.7 1.7 18.3 10.3 14 1.6 18.3 9.9 121 7 124 165 3.3 0 3.5 3 04/22/2007 04:30:00 14.4 1.9 20.6 9.5 14.6 1.9 21.4 9.9 13.7 1.9 19.9 9.1 118 6 124 165 3.3 0 3.5 3 04/22/2007 04:40:00 14.6 1.6 19.1 8.8 14.9 1.7 19.9 9.5 14 1.7 19.1 9.5 116 7 110 165 3.3 0 3.5 2.8 04/22/2007 04:50:00 14.8 1.3 19.1 10.3 15 1.3 19.5 10.3 14.2 1.6 19.1 10.3 117 6 116 165 3.3 0 3.5 3 04/22/2007 05:00:00 15.4 1.7 21 9.9 15.6 1.7 21.4 10.3 14.9 1.8 20.6 10.3 119 6 119 165 3.3 0 3.5 3 04/22/2007 05:10:00 15.4 1.7 19.5 11.1 15.5 1.7 19.5 11.5 14.9 1.8 19.9 9.9 119 6 125 165 3.3 0 3.5 3 04/22/2007 05:20:00 14.9 1.5 18.7 10.3 15.1 1.5 18.7 10.3 14.3 1.7 19.1 9.5 119 6 117 165 3.3 0 3.5 3 04/22/2007 05:30:00 14.4 1.7 18.3 10.7 14.5 1.7 18.3 10.3 14 1.8 18.7 8.8 122 6 121 165 3.3 0 3.5 3 04/22/2007 05:40:00 14.7 1.5 19.5 9.9 14.9 1.5 19.9 9.5 14.3 1.6 19.1 10.3 120 6 124 165 3.3 0 3.5 2.8 04/22/2007 05:50:00 15.5 1.7 19.5 11.8 15.6 1.7 20.2 12.2 15.1 1.7 19.1 10.3 124 7 132 165 3.3 0 3.5 3 04/22/2007 06:00:00 15.4 1.9 20.2 10.7 15.5 1.9 21 11.1 15 1.9 19.1 10.3 123 6 123 165 3.3 0 3.5 3 04/22/2007 06:10:00 14.7 1.7 18.7 10.3 14.8 1.7 18.3 9.9 14.2 1.7 18.3 9.5 122 8 122 165 3.3 0 3.5 3 04/22/2007 06:20:00 14.6 1.7 18.7 10.3 14.7 1.7 19.1 10.3 14.2 1.8 19.1 9.9 121 6 121 165 3.3 0 3.5 2.8 04/22/2007 06:30:00 14.6 1.2 19.5 10.7 14.8 1.3 19.9 11.1 13.9 1.5 17.9 9.1 118 7 119 165 3.3 0 3.5 2.8 04/22/2007 06:40:00 14.3 1.7 19.1 10.3 14.5 1.7 19.5 10.3 13.8 1.9 17.9 9.1 120 8 121 165 3.3 0 3.5 2.8 04/22/2007 06:50:00 13.9 1.3 18.3 10.7 14.1 1.3 18.3 10.7 13.2 1.2 16.8 10.3 117 6 117 165 3.3 0 3.5 2.8 04/22/2007 07:00:00 14.2 1.9 19.1 9.1 14.4 2 19.1 9.1 13.5 2.1 19.5 9.1 116 6 116 165 3.3 0 3.5 2.8 04/22/2007 07:10:00 14.3 1.7 18.3 9.5 14.5 1.7 18.3 9.9 13.7 1.9 17.9 9.5 119 8 122 165 3.2 0 3.5 2.8 04/22/2007 07:20:00 15.2 1.5 19.9 11.8 15.4 1.5 19.9 11.5 14.4 1.7 18.7 9.9 115 7 114 165 3.2 0 3.5 2.8 04/22/2007 07:30:00 14.9 1.5 19.1 9.9 15.1 1.5 19.9 10.7 14.2 1.6 18.7 9.9 117 7 108 165 3.3 0 3.5 2.8 04/22/2007 07:40:00 15.4 1.7 19.5 11.1 15.6 1.7 19.9 11.1 14.9 1.7 19.1 10.7 117 7 107 165 3.2 0 3.5 2.6 04/22/2007 07:50:00 15.1 1.4 18.7 9.5 15.4 1.5 19.1 9.5 14.4 1.6 19.1 9.5 115 6 116 165 3.2 0 3.3 3 04/22/2007 08:00:00 15 1.7 19.5 9.1 15.2 1.7 19.9 9.5 14.3 1.7 19.5 9.5 117 7 101 165 3.2 0 3.5 2.6 04/22/2007 08:10:00 15.2 1.7 19.1 11.5 15.4 1.7 19.1 11.5 14.2 1.8 18.7 9.5 117 7 112 165 3.2 0 3.3 2.8 04/22/2007 08:20:00 14.7 1.5 19.1 11.1 15 1.5 19.1 10.3 14 1.8 18.7 8 117 6 125 165 3.2 0 3.5 2.8 04/22/2007 08:30:00 14.4 1.7 17.9 8 14.6 1.7 18.3 7.6 13.8 1.6 17.9 9.1 119 6 122 165 3.3 0 3.5 2.8 04/22/2007 08:40:00 15.4 1.7 20.2 10.7 15.5 1.8 20.2 9.5 14.7 1.8 19.9 9.9 121 8 121 165 3.2 0 3.5 3 04/22/2007 08:50:00 14.4 1.9 20.2 9.1 14.6 1.9 20.2 9.5 13.9 1.7 19.9 9.5 121 6 121 165 3.2 0 3.5 2.8 04/22/2007 09:00:00 15.9 1.7 19.9 11.1 16.1 1.7 20.6 11.8 15.4 1.8 19.9 9.1 120 7 114 165 3.2 0 3.5 2.8 04/22/2007 09:10:00 15.5 1.6 20.2 9.1 15.7 1.6 20.6 9.9 14.9 1.7 19.9 10.7 121 7 122 165 3.2 0 3.5 3 04/22/2007 09:20:00 15.6 1.8 20.6 11.8 15.8 1.8 21 12.2 15.1 1.9 21.8 10.7 121 6 118 165 3.2 0 3.5 2.8 04/22/2007 09:30:00 16.1 2.2 21.4 10.3 16.2 2.2 21.8 11.1 15.6 2.2 20.6 10.7 121 7 119 165 3.2 0 3.5 2.8 04/22/2007 09:40:00 16.8 1.7 20.6 12.6 17 1.7 21 13 16.3 1.9 21 11.1 123 6 122 165 3.1 0 3.3 2.8 04/22/2007 09:50:00 15.8 1.7 21.4 10.7 15.9 1.7 21.4 10.7 15.3 1.7 19.1 10.7 124 8 127 165 3.1 0 3.3 2.8 04/22/2007 10:00:00 15.4 1.7 20.2 10.3 15.5 1.7 21 11.1 14.7 1.8 19.9 9.9 120 8 121 165 3.1 0 3.5 2.8 04/22/2007 10:10:00 15.7 1.8 21 11.5 15.9 1.8 21.4 11.8 15.4 1.9 21 10.7 123 7 125 165 3 0.1 3.3 2.6 04/22/2007 10:20:00 16.7 2 21 11.5 16.9 2 21.4 11.5 16.2 2.2 20.6 10.7 120 6 117 165 2.8 0.1 3 2.3 04/22/2007 10:30:00 16.3 1.8 20.6 11.5 16.4 1.8 21 11.5 16.1 1.9 20.2 11.1 123 8 129 165 2.7 0.1 3 2.3 04/22/2007 10:40:00 15.7 1.5 18.7 11.8 15.8 1.5 18.7 11.8 15.2 1.6 18.7 10.3 125 6 119 165 2.6 0.1 2.8 2.1 04/22/2007 10:50:00 14.4 1.7 19.1 10.7 14.5 1.7 19.5 10.7 14 1.7 19.1 10.7 123 7 121 165 2.7 0 2.8 2.1 04/22/2007 11:00:00 13.8 1.5 17.6 9.9 13.9 1.5 17.6 8.4 13.3 1.5 17.6 9.1 120 7 121 165 2.7 0 2.8 2.6 04/22/2007 11:10:00 13.4 1.8 17.6 8.4 13.5 1.8 17.9 9.1 12.8 2 17.9 8 120 7 123 165 2.7 0 2.8 2.3 04/22/2007 11:20:00 13.9 1.5 17.2 10.7 14.1 1.5 17.6 9.9 13 1.5 17.2 9.5 117 7 109 165 2.7 0 3 2.6 04/22/2007 11:30:00 14.5 1.9 20.6 8.8 14.7 2 21 8.8 13.9 2.2 20.6 9.1 114 7 117 165 2.7 0 2.8 2.1 04/22/2007 11:40:00 13.8 1.8 18.7 8.8 14.1 1.8 19.5 9.1 13.2 1.7 17.6 9.1 115 6 111 165 2.6 0 2.8 2.1 04/22/2007 11:50:00 14.3 1.8 18.3 9.5 14.6 1.9 18.7 9.5 13.6 2 18.7 8.4 109 7 109 165 2.6 0 2.8 2.3 04/22/2007 12:00:00 13.5 1.5 17.2 8.8 13.8 1.5 17.2 8.8 12.8 1.6 16.8 8.8 112 8 121 165 2.7 0 2.8 2.3 04/22/2007 12:10:00 15.2 1.5 18.3 10.7 15.5 1.5 19.1 11.1 14.4 1.7 18.7 9.9 109 7 107 165 2.7 0 2.8 2.3 04/22/2007 12:20:00 15.1 1.5 19.5 9.9 15.3 1.5 20.2 9.9 14.4 1.7 19.9 9.5 109 7 108 165 2.7 0 2.8 2.6 04/22/2007 12:30:00 14.7 2.1 19.1 9.1 14.9 2.1 19.9 9.5 14 2.1 18.7 8.4 112 7 116 165 2.7 0 2.8 2.6 04/22/2007 12:40:00 14 1.7 19.5 9.9 14.3 1.7 19.1 9.9 13.4 1.8 18.3 9.1 113 8 119 165 2.7 0 2.8 2.3 04/22/2007 12:50:00 14.9 1.5 18.7 10.7 15.1 1.5 18.7 10.7 14.2 1.7 18.3 9.5 111 6 114 165 2.7 0 2.8 2.3 04/22/2007 13:00:00 13.9 1.6 18.3 9.9 14.1 1.6 18.7 10.3 13 1.7 17.9 8 113 8 121 165 2.7 0 2.8 2.6 04/22/2007 13:10:00 14.7 2.1 19.9 9.1 14.9 2.2 19.9 9.1 13.8 2.4 19.1 8 113 8 129 165 2.6 0 2.8 2.1 04/22/2007 13:20:00 14.4 1.7 18.3 9.5 14.6 1.8 19.1 9.5 13.6 2 19.1 8.8 112 8 108 165 2.6 0 2.8 2.3 04/22/2007 13:30:00 14.7 1.3 18.7 10.7 15 1.5 19.1 10.7 13.9 1.7 19.1 9.5 111 6 117 165 2.7 0 3 2.3 04/22/2007 13:40:00 14.3 1.9 18.7 9.5 14.6 2 19.5 9.9 13.3 2.1 17.9 8.4 109 8 102 165 2.8 0 3 2.6 04/22/2007 13:50:00 13.4 2 17.9 7.6 13.7 2 18.3 8 12.7 2 17.2 7.2 111 7 113 165 2.9 0 3 2.6 04/22/2007 14:00:00 14 1.7 17.9 9.9 14.3 1.7 18.7 10.3 13.2 1.7 17.6 8.8 108 6 98 165 2.9 0 3.3 2.6 04/22/2007 14:10:00 14 1.3 17.2 10.3 14.2 1.4 17.9 10.3 13.1 1.5 17.2 8.8 109 7 111 165 3 0.1 3.3 2.6 04/22/2007 14:20:00 14.1 1.3 17.6 10.3 14.4 1.3 17.9 10.7 13.3 1.7 18.3 9.1 109 6 106 165 3 0.1 3.3 2.3 04/22/2007 14:30:00 14.9 1.4 19.1 11.5 15.1 1.4 19.5 10.7 14 1.7 19.9 10.3 112 7 106 165 2.9 0 3.3 2.6 04/22/2007 14:40:00 13.4 1.4 16.8 9.9 13.6 1.4 17.2 9.9 12.4 1.5 16.4 8 111 7 119 165 2.9 0 3.3 2.6 04/22/2007 14:50:00 14 1.7 18.3 10.7 14.3 1.7 18.7 10.7 13.2 1.7 17.9 8.8 105 6 102 165 2.9 0 3.3 2.6 04/22/2007 15:00:00 15.2 1.7 18.7 11.1 15.5 1.7 19.5 11.1 14.2 2.1 19.5 8.4 109 8 99 165 2.9 0 3.3 2.8 04/22/2007 15:10:00 13.7 1.5 17.2 8.8 14 1.5 17.6 9.1 13.1 1.6 17.6 8.4 112 8 122 165 2.9 0 3 2.6 04/22/2007 15:20:00 14.5 1.5 19.1 10.3 14.7 1.5 19.5 9.9 13.9 1.6 17.6 9.5 109 7 100 165 2.9 0 3 2.3 04/22/2007 15:30:00 13.5 1.6 16.8 9.5 13.7 1.6 17.2 9.5 12.6 1.7 16.4 7.6 110 7 99 165 3 0.1 3.3 2.3 04/22/2007 15:40:00 13.9 1.7 18.7 9.1 14.2 1.7 19.1 9.5 13.2 2 17.6 6.5 110 7 98 165 2.9 0 3 2.3 04/22/2007 15:50:00 13.6 2 18.3 9.1 13.9 2 19.1 9.5 12.8 2.2 17.9 7.6 106 8 102 165 2.9 0 3 2.3 04/22/2007 16:00:00 13 1.9 17.9 7.6 13.2 2 18.3 8 12.3 2 17.9 6.1 108 7 101 165 2.9 0 3 2.3 04/22/2007 16:10:00 14 1.2 18.3 9.5 14.3 1.2 18.7 10.3 13.2 1.3 16.8 9.5 103 5 102 165 3 0.1 3.3 2.6 04/22/2007 16:20:00 14.3 1.7 18.3 9.5 14.6 1.7 18.7 9.9 13.5 1.7 17.2 8.8 104 8 123 165 3 0 3.3 2.3 04/22/2007 16:30:00 13.3 1.9 17.6 8 13.6 2 17.6 8 12.5 1.9 16.8 7.6 108 7 102 165 3 0.1 3.3 2.3 04/22/2007 16:40:00 14 1.6 17.6 9.9 14.3 1.6 17.6 9.9 13.2 1.5 16.4 8.4 106 7 97 165 2.9 0.1 3 2.3 04/22/2007 16:50:00 15.5 1.7 19.5 10.7 15.8 1.7 19.1 9.9 14.7 1.8 18.7 9.5 107 6 105 165 2.8 0 3 2.6 04/22/2007 17:00:00 14 1.5 17.9 9.5 14.3 1.5 17.9 9.5 13.1 1.7 16.4 8.8 104 7 113 165 2.9 0 3.3 2.3 04/22/2007 17:10:00 14.4 1.5 18.3 10.3 14.7 1.5 17.9 11.1 13.5 1.5 17.2 9.9 106 7 101 165 2.9 0.2 3.3 2.3 04/22/2007 17:20:00 13.8 1.7 17.2 8.4 14.2 1.7 17.9 8.8 13 1.6 16.8 8.8 105 8 105 165 2.9 0.2 3.3 2.3 04/22/2007 17:30:00 14.4 1.4 18.3 10.7 14.7 1.4 18.7 10.3 13.5 1.5 17.6 9.5 103 6 91 165 2.9 0.2 3.3 2.3 04/22/2007 17:40:00 14.8 1.7 18.7 10.3 15.1 1.7 19.1 10.3 13.8 1.8 17.9 9.9 103 6 98 165 2.9 0.2 3.3 2.3 04/22/2007 17:50:00 14 1.5 17.2 9.5 14.4 1.5 17.2 9.1 13.2 1.5 16.4 8.4 103 6 106 165 2.9 0.2 3.3 2.6 04/22/2007 18:00:00 14.3 1.7 18.7 8 14.6 1.7 19.1 8.8 13.5 1.8 19.1 7.6 104 7 111 165 2.9 0.2 3.5 2.6 04/22/2007 18:10:00 14.3 1.7 18.3 8.8 14.6 1.7 18.7 9.5 13.3 1.9 17.6 6.5 106 7 108 165 2.9 0.2 3.3 2.6 04/22/2007 18:20:00 13 1.4 16.4 8.4 13.4 1.4 16.8 8.8 12.3 1.4 16.1 7.6 101 6 109 165 3 0.2 3.5 2.6 04/22/2007 18:30:00 13.9 1.6 17.9 9.5 14.3 1.7 18.3 9.9 13.1 1.6 17.6 9.1 100 7 102 165 3 0.1 3.5 2.6 04/22/2007 18:40:00 14 1.3 17.2 9.9 14.3 1.3 17.6 9.9 13.2 1.5 16.8 8 104 6 104 165 3.2 0.1 3.5 2.8 04/22/2007 18:50:00 13.3 1.5 16.8 8.4 13.7 1.5 17.6 8.8 12.5 1.7 16.4 8.4 103 6 108 165 3.2 0.1 3.5 2.8 04/22/2007 19:00:00 13.4 1.4 16.8 9.9 13.7 1.4 17.6 9.5 12.6 1.5 16.8 8.8 100 6 93 165 3.2 0.1 3.5 2.8 04/22/2007 19:10:00 14.4 1.6 18.7 9.9 14.7 1.6 18.7 9.9 13.4 1.7 16.8 8.4 104 6 107 165 3.2 0.1 3.5 2.8 04/22/2007 19:20:00 13.8 1.7 18.7 8.8 14.1 1.7 19.1 9.5 13 1.7 18.3 8 102 6 99 165 3.1 0.1 3.5 2.6 04/22/2007 19:30:00 13.8 1.2 16.8 9.1 14.1 1.3 17.6 9.5 13 1.5 16.4 8.4 99 7 105 165 3.2 0.1 3.5 2.8 04/22/2007 19:40:00 14 1.5 19.1 9.5 14.4 1.5 18.3 9.9 13.3 1.5 17.2 9.1 101 7 105 165 3.1 0.1 3.5 2.8 04/22/2007 19:50:00 15.1 1.6 19.5 10.7 15.5 1.6 19.5 10.7 14.4 1.7 19.9 9.5 105 6 105 165 3 0.1 3.5 2.6 04/22/2007 20:00:00 12.7 1.8 17.9 8.4 13 1.9 18.3 8.8 11.9 1.9 17.9 8 104 7 107 165 3 0.2 3.3 2.6 04/22/2007 20:10:00 13.1 1.9 17.2 8 13.4 2 17.6 8.4 12.3 2 17.2 7.2 94 8 99 165 3.1 0.1 3.5 2.8 04/22/2007 20:20:00 14 1.9 19.5 8 14.3 1.9 20.2 8.8 13.3 2.1 18.7 7.6 100 8 98 165 3 0.2 3.3 2.6 04/22/2007 20:30:00 14 1.6 18.7 9.9 14.4 1.7 19.5 9.9 13.3 1.7 18.7 8 98 7 102 165 3 0.2 3.3 2.3 04/22/2007 20:40:00 14.2 1.3 17.9 9.9 14.5 1.3 17.6 9.9 13.4 1.4 16.8 9.5 97 6 102 165 2.9 0.2 3.3 2.3 04/22/2007 20:50:00 14.3 1.6 18.7 10.7 14.7 1.6 19.1 10.7 13.4 1.5 17.6 9.5 98 6 102 165 3 0.2 3.3 2.6 04/22/2007 21:00:00 13.8 1.5 17.2 8.4 14.1 1.5 17.6 9.5 12.9 1.7 17.9 8.4 101 7 94 165 3 0.2 3.3 2.6 04/22/2007 21:10:00 13.8 1.7 17.2 8.8 14.1 1.7 17.2 8.8 13 1.7 17.2 8.4 102 6 111 165 2.9 0.2 3.3 2.6 04/22/2007 21:20:00 12.6 1.3 16.4 8.4 13 1.3 16.8 9.1 11.8 1.5 16.4 8 103 6 103 165 2.9 0.2 3.3 2.6 04/22/2007 21:30:00 12.8 1.8 17.9 9.5 13.2 1.8 18.3 9.5 12.2 1.8 17.6 8.4 99 8 109 165 2.9 0.2 3.3 2.3 04/22/2007 21:40:00 13.1 1.7 16.4 9.5 13.5 1.6 16.8 9.5 12.3 1.7 16.4 8 99 7 99 165 2.9 0.2 3.3 2.3 04/22/2007 21:50:00 12.8 1.9 17.2 8 13.2 1.9 17.6 8 12.5 1.8 17.2 7.6 87 6 91 165 2.9 0.2 3.3 2.6 04/22/2007 22:00:00 14.1 1.7 18.3 9.5 14.5 1.7 18.7 9.9 13.6 1.6 17.2 9.5 83 6 83 165 3 0.2 3.3 2.6 04/22/2007 22:10:00 14.6 1.5 18.3 10.7 14.9 1.5 18.3 10.3 13.7 1.5 17.2 8.8 84 6 89 165 3.1 0.1 3.5 2.8 04/22/2007 22:20:00 14 1.3 17.2 9.9 14.3 1.4 17.2 10.3 13.3 1.3 16.8 9.5 83 6 94 165 3.1 0.1 3.5 2.8 04/22/2007 22:30:00 13.6 1.6 17.2 9.1 14 1.7 17.6 8.8 12.9 1.6 17.2 8.8 82 6 88 165 3.2 0.1 3.5 2.8 04/22/2007 22:40:00 12.6 1.2 15.3 9.5 12.8 1.3 16.4 9.5 12 1.3 16.1 8.8 80 7 89 165 3.2 0 3.5 2.8 04/22/2007 22:50:00 13.5 1.3 16.8 10.3 13.8 1.3 17.2 10.3 12.9 1.3 15.6 10.3 79 7 84 165 3.2 0 3.5 2.8 04/22/2007 23:00:00 13.8 1.5 17.6 9.5 14.1 1.6 17.9 9.5 13.2 1.5 17.2 8.8 82 7 98 165 3.2 0 3.5 2.8 04/22/2007 23:10:00 12.8 1.9 16.8 8.4 13.1 1.9 17.2 8.4 12.4 1.7 16.8 8 81 7 79 165 3.2 0 3.5 2.8 04/22/2007 23:20:00 13 1.8 17.9 8.8 13.3 1.8 17.9 8.8 12.5 1.7 16.8 8.4 82 8 99 165 3.2 0 3.5 2.8 04/22/2007 23:30:00 13.6 1.7 17.2 8.8 13.9 1.7 17.6 9.5 13 1.9 16.4 8.8 84 7 83 165 3.2 0 3.5 2.8 04/22/2007 23:40:00 11.4 1.7 16.1 7.6 11.6 1.7 16.4 7.6 10.9 1.6 15.6 7.2 79 8 81 165 3.2 0 3.5 2.8 04/22/2007 23:50:00 12.7 2 16.8 8.4 13.1 2 17.6 8.8 12.3 1.8 16.4 8 84 7 85 165 3.2 0 3.5 2.8 04/23/2007 00:00:00 12.2 1.8 17.2 8.4 12.5 1.8 17.6 8.8 12 1.7 16.8 8.8 80 8 87 165 3.1 0.1 3.5 2.8 04/23/2007 00:10:00 12.8 2.1 17.9 7.6 13.2 2.2 18.3 8.4 12.4 1.9 17.9 8.8 86 8 84 165 3 0.1 3.3 2.6 04/23/2007 00:20:00 11.9 1.5 15.3 7.2 12.2 1.5 15.6 7.6 11.4 1.5 14.5 8 90 7 91 165 2.7 0.3 3.3 2.1 04/23/2007 00:30:00 12.1 1.5 15.3 8.4 12.4 1.5 16.1 8 11.4 1.4 14.5 7.6 89 6 92 165 2.7 0.2 3 2.3 04/23/2007 00:40:00 12.3 1.8 16.4 7.6 12.6 1.9 16.8 7.6 11.9 1.7 16.4 7.6 86 8 87 165 2.6 0.3 3 2.1 04/23/2007 00:50:00 12.1 1.3 15.3 7.6 12.5 1.4 15.6 8 11.7 1.3 15.3 8.4 87 8 84 165 2.7 0.1 3 2.1 04/23/2007 01:00:00 11 1.3 15.6 8 11.3 1.4 15.6 8 10.6 1.3 14.5 7.6 88 6 87 165 2.7 0.2 3 2.1 04/23/2007 01:10:00 10.1 1.4 13 6.1 10.4 1.5 13.7 5.7 9.7 1.3 13 6.5 83 8 87 165 2.7 0.2 3 2.3 04/23/2007 01:20:00 11.1 1.6 15.3 7.6 11.4 1.7 16.1 7.6 10.9 1.6 14.9 7.2 77 9 81 165 2.7 0.3 3.3 2.1 04/23/2007 01:30:00 9 1.6 13.7 5.3 9.4 1.7 13.7 6.1 8.8 1.6 13 5.7 76 9 75 165 2.8 0.2 3.3 2.3 04/23/2007 01:40:00 10.3 1.6 14.5 6.5 10.6 1.7 14.5 6.5 9.9 1.4 13.3 7.2 73 9 71 165 2.8 0.2 3 2.3 04/23/2007 01:50:00 11.4 1.4 14.9 7.2 11.7 1.5 15.6 8 10.8 1.3 14.5 8 83 7 87 165 2.8 0.2 3 2.3 04/23/2007 02:00:00 11.4 1.3 15.3 7.6 11.8 1.3 15.6 7.6 10.9 1.2 13.7 8 84 6 85 165 3 0.1 3.3 2.6 04/23/2007 02:10:00 10.8 1.2 14.1 8 11.1 1.3 14.5 7.6 10.3 1.2 13.7 7.6 81 7 84 165 3.1 0 3.3 2.8 04/23/2007 02:20:00 9.5 1.4 13.7 5.7 9.8 1.5 14.1 6.1 9.3 1.4 13.7 6.5 78 8 84 165 3 0.1 3.3 2.8 04/23/2007 02:30:00 9.9 1.2 13 6.5 10.2 1.3 13.3 6.8 9.5 1.3 13 6.5 76 8 90 165 3 0.1 3.3 2.6 04/23/2007 02:40:00 9.7 1.2 13.3 6.8 10 1.3 13.7 6.8 9.4 1.3 13 6.8 77 7 82 165 3 0 3.3 2.8 04/23/2007 02:50:00 10 1.2 13 7.2 10.3 1.3 13.3 7.2 9.6 1.2 12.6 6.1 79 6 72 165 3 0 3.3 2.8 04/23/2007 03:00:00 9.4 1.2 13.7 6.8 9.8 1.3 13.7 6.1 9.2 1.3 13.3 6.5 81 8 75 165 3 0.1 3.3 2.6 04/23/2007 03:10:00 9.8 1 12.6 6.8 10.1 1.1 13.3 6.8 9.4 1.1 12.6 6.5 80 7 82 165 3 0.1 3.3 2.6 04/23/2007 03:20:00 9.9 1.1 13 7.2 10.3 1.1 13.3 7.2 9.6 1.1 12.6 6.8 82 7 91 165 3 0.1 3.3 2.6 04/23/2007 03:30:00 9.3 1.2 12.2 6.5 9.6 1.3 12.6 6.8 9.1 1.3 12.2 6.5 81 7 90 165 3 0.1 3.3 2.6 04/23/2007 03:40:00 9 1.1 11.8 6.5 9.4 1.1 12.2 6.5 8.9 1 12.2 6.5 78 7 78 165 3 0.1 3.3 2.6 04/23/2007 03:50:00 9 1.1 11.8 5.7 9.3 1.2 12.6 6.1 8.7 1.1 11.5 6.1 78 8 89 165 2.9 0.1 3.3 2.6 04/23/2007 04:00:00 9.2 1.1 13 5.7 9.5 1.2 13.3 6.1 8.8 1.1 12.2 6.1 79 8 75 165 3 0.1 3.3 2.6 04/23/2007 04:10:00 7.9 1.2 11.5 4.9 8.1 1.3 12.2 5.7 7.7 1.2 11.1 4.2 71 9 73 165 3 0.1 3.3 2.6 04/23/2007 04:20:00 8.4 1.2 11.5 5.3 8.7 1.3 11.8 5.3 8.2 1.2 11.5 5.7 75 9 89 165 3 0.1 3.3 2.6 04/23/2007 04:30:00 8.8 1.1 11.8 5.3 9.1 1.2 12.2 5.7 8.6 1.1 12.2 6.1 77 8 83 165 2.9 0.1 3.3 2.6 04/23/2007 04:40:00 10 1.1 13 7.2 10.3 1.2 13.3 7.6 9.6 1.1 12.6 6.8 80 7 88 165 3 0.1 3.3 2.6 04/23/2007 04:50:00 9.4 1.1 12.2 6.1 9.8 1.1 12.6 6.8 9.2 1 11.8 6.5 81 7 83 165 2.9 0.1 3.3 2.6 04/23/2007 05:00:00 8.9 1.3 12.6 5.7 9.2 1.3 13 6.5 8.6 1.2 11.8 5.7 77 7 84 165 3 0.1 3.3 2.6 04/23/2007 05:10:00 8.6 1.3 12.2 4.9 8.9 1.3 12.6 5.3 8.4 1.1 11.1 5.7 73 7 83 165 2.9 0.1 3.3 2.6 04/23/2007 05:20:00 8.6 1.2 12.2 4.9 8.9 1.2 12.2 5.3 8.1 1.2 11.8 5.3 71 9 80 165 2.9 0.1 3.3 2.6 04/23/2007 05:30:00 8.2 1.3 11.8 5.3 8.6 1.3 12.2 5.7 8.1 1.3 11.5 5.7 75 8 80 165 3 0.1 3.3 2.6 04/23/2007 05:40:00 8.8 1.2 11.8 5.3 9.1 1.3 12.2 5.7 8.6 1.1 11.5 5.3 76 7 76 165 3.1 0 3.3 2.8 04/23/2007 05:50:00 8.2 1.2 11.1 4.9 8.6 1.2 11.5 5.3 8.2 1 11.1 5.3 72 9 71 165 3 0 3.3 2.8 04/23/2007 06:00:00 6.6 1.2 9.5 4.2 7 1.1 9.5 4.6 6.5 1 9.1 4.6 67 8 79 165 3 0 3.3 2.8 04/23/2007 06:10:00 6.6 1.2 9.5 3.4 6.9 1.2 10.3 3.8 6.5 1 9.9 4.2 65 8 83 165 3 0 3.3 2.8 04/23/2007 06:20:00 6.8 1 9.9 4.2 7.1 1 10.3 4.6 6.7 0.9 8.8 4.2 67 9 57 165 3 0 3.3 2.8 04/23/2007 06:30:00 7.2 1.1 9.9 4.9 7.5 1.1 10.7 4.9 7.2 1 9.5 5.3 68 8 74 165 3 0 3.3 2.8 04/23/2007 06:40:00 7.1 1.3 10.7 4.2 7.4 1.3 11.1 4.9 7 1.1 10.3 4.6 66 9 78 165 3.1 0 3.3 2.8 04/23/2007 06:50:00 6.7 1.1 9.5 4.2 7 1.1 9.9 4.6 6.8 1 9.5 4.2 68 9 67 165 3 0 3.3 2.8 04/23/2007 07:00:00 6.6 1 8.8 4.6 6.9 1 9.5 4.9 6.7 0.9 9.1 4.6 67 9 68 165 3 0 3.3 2.8 04/23/2007 07:10:00 6.3 1.2 9.1 3.8 6.7 1.2 9.5 3.8 6.3 1.1 9.5 3.8 66 9 63 165 3 0 3.3 2.8 04/23/2007 07:20:00 5.7 1 8.4 3 6 1.1 8.8 3.4 5.8 1 8 3 62 10 65 165 3 0 3.3 2.8 04/23/2007 07:30:00 5.8 1.2 9.1 3.4 6.1 1.2 9.1 3.4 5.9 1.1 8.8 3.8 63 11 64 165 3 0.1 3.3 2.6 04/23/2007 07:40:00 7.2 1.5 10.3 3.8 7.5 1.5 10.7 3.8 7.1 1.4 10.7 4.2 71 9 87 165 3 0.1 3.3 2.6 04/23/2007 07:50:00 7.3 0.9 9.5 4.9 7.5 0.8 9.5 5.3 7.1 0.8 9.1 5.3 77 7 87 165 3 0.1 3.3 2.8 04/23/2007 08:00:00 7.2 1.1 9.9 4.6 7.5 1.1 10.3 5.3 7.2 1 10.3 4.6 78 8 81 165 3 0 3.3 2.8 04/23/2007 08:10:00 8.4 1 10.7 6.1 8.7 1 11.1 6.1 8 1 10.7 5.7 80 7 84 165 3 0 3.3 2.8 04/23/2007 08:20:00 7 1.2 9.9 4.6 7.3 1.2 10.3 4.6 7.1 1.1 9.9 4.6 72 9 87 165 2.8 0.1 3 2.3 04/23/2007 08:30:00 6.3 1.2 9.5 2.6 6.6 1.2 9.9 3.8 6.3 1 9.5 4.2 68 9 73 165 2.8 0.1 3.3 2.3 04/23/2007 08:40:00 5.8 1.3 9.9 3 6.2 1.3 10.3 3.4 5.8 1.2 9.5 3.4 62 9 66 165 3 0.1 3.3 2.6 04/23/2007 08:50:00 5.7 1.1 8.8 3 6 1.2 9.1 3.4 5.8 1 9.1 3.4 62 12 78 165 3 0 3.3 2.8 04/23/2007 09:00:00 6.1 1.2 9.1 3.8 6.4 1.3 9.1 3.8 6.1 1 8.8 3.4 66 9 65 165 3 0 3.3 2.8 04/23/2007 09:10:00 5.4 0.7 8 3.8 5.7 0.7 8 4.2 5.6 0.6 7.6 4.2 64 8 67 165 3 0 3.3 2.8 04/23/2007 09:20:00 4.8 1 7.2 2.6 5.2 1 7.2 3 5 1 7.6 3 67 9 84 165 3.1 0 3.3 2.8 04/23/2007 09:30:00 5.6 1.1 8.8 2.6 5.9 1.1 8.8 2.3 5.7 1 8 3 66 9 81 165 3.3 0 3.5 3.3 04/23/2007 09:40:00 4.9 1 8 2.6 5.2 1.1 8.4 2.6 5 1.1 7.6 2.6 65 12 80 165 3.3 0 3.5 2.8 04/23/2007 09:50:00 5.5 1 8 3.4 5.9 1 8.8 3.4 5.6 1 8.8 3.4 72 9 88 165 3.3 0.1 3.5 2.8 04/23/2007 10:00:00 7.2 1.4 9.9 3.4 7.6 1.4 10.7 3 7.1 1.3 10.3 4.2 81 8 84 165 3.4 0.1 3.5 2.8 04/23/2007 10:10:00 8.5 1 10.3 5.7 8.8 1 11.1 6.1 8 1 9.9 4.9 86 6 88 165 3.5 0.1 3.8 3.3 04/23/2007 10:20:00 8.6 1 10.3 6.1 8.9 1 10.7 6.1 8.2 1 10.3 5.7 88 6 92 165 3.5 0.2 3.5 2.8 04/23/2007 10:30:00 9.2 0.9 10.7 6.5 9.6 0.9 11.5 6.5 9 0.9 10.7 6.5 91 5 84 165 3.5 0.1 3.8 3 04/23/2007 10:40:00 9.1 0.9 11.5 5.7 9.5 0.9 11.5 6.5 8.7 0.8 10.3 6.1 94 5 92 165 3.6 0.1 3.8 3.3 04/23/2007 10:50:00 8 1 10.3 5.3 8.4 1 10.7 5.3 7.8 0.9 9.9 5.3 94 6 90 165 3.6 0 3.8 3.5 04/23/2007 11:00:00 7.9 0.9 9.9 4.9 8.3 0.9 10.3 5.3 7.6 0.9 9.9 5.7 94 7 99 165 3.5 0.1 3.8 3 04/23/2007 11:10:00 8.4 0.9 10.7 6.1 8.8 0.9 11.5 6.5 8.1 1 11.1 5.3 92 6 92 165 3.6 0.1 3.8 3.3 04/23/2007 11:20:00 8.5 0.9 10.7 6.1 8.9 0.9 10.7 6.5 8.1 0.9 9.9 5.3 99 6 98 165 3.5 0.1 3.8 3 04/23/2007 11:30:00 7.6 1 9.5 4.9 7.9 1 9.9 5.7 7.1 1 9.1 4.6 101 5 108 165 3.6 0 3.8 3.3 04/23/2007 11:40:00 7.7 1 10.3 5.3 8.1 0.9 10.3 5.7 7.3 0.9 9.1 5.3 99 6 106 165 3.6 0 3.8 3.3 04/23/2007 11:50:00 8.1 0.7 9.5 5.3 8.4 0.7 9.5 6.1 7.7 0.7 9.1 5.7 94 5 94 165 3.8 0 4 3.5 04/23/2007 12:00:00 7.3 1 9.1 4.9 7.7 1 9.5 5.3 7.2 0.9 8.8 4.9 85 7 93 165 3.8 0 4 3.8 04/23/2007 12:10:00 7.5 1.2 9.9 4.2 7.9 1.2 10.3 4.6 7.5 1.1 9.5 4.6 80 7 74 165 3.7 0 4 3.5 04/23/2007 12:20:00 8 1.1 10.7 5.7 8.4 1.1 11.1 6.1 8.1 1 11.1 6.1 79 7 84 165 3.6 0 3.8 3.5 04/23/2007 12:30:00 7.9 1 9.9 4.6 8.2 1 10.7 4.6 7.7 0.9 9.9 4.6 82 8 77 165 3.6 0 3.8 3.5 04/23/2007 12:40:00 8.4 1 11.1 6.1 8.8 1 11.8 6.5 8.3 1 11.1 6.1 82 8 84 165 3.5 0 3.8 3.5 04/23/2007 12:50:00 7.6 1.1 10.7 4.9 8 1.1 11.5 4.9 7.7 1.1 10.7 5.3 79 8 81 165 3.5 0 3.8 3.3 04/23/2007 13:00:00 8.3 1.3 11.8 5.3 8.7 1.3 12.2 4.9 8.2 1.2 11.1 5.3 81 8 73 165 3.5 0 3.8 3.3 04/23/2007 13:10:00 8.1 1 10.7 4.9 8.4 1 11.1 5.3 7.9 1 11.1 4.9 75 9 77 165 3.5 0 3.8 3.5 04/23/2007 13:20:00 8.6 1.5 12.2 4.2 8.9 1.6 12.6 4.6 8.5 1.4 12.2 5.3 72 8 67 165 3.5 0 3.8 3.5 04/23/2007 13:30:00 8.8 1 11.8 6.5 9 1.1 12.2 6.5 8.6 1 11.1 6.1 70 6 74 165 3.4 0 3.5 3.3 04/23/2007 13:40:00 8.2 1.1 10.7 5.3 8.5 1.1 11.1 5.7 8.1 1 10.7 5.7 69 7 71 165 3.4 0 3.5 3.3 04/23/2007 13:50:00 7.7 1.3 11.5 4.9 7.9 1.2 11.1 5.3 7.6 1.3 11.1 4.9 69 9 54 165 3.4 0 3.5 3.3 04/23/2007 14:00:00 7.4 1 9.5 5.3 7.7 1 9.9 5.7 7.4 1 9.5 4.9 65 8 76 165 3.4 0 3.5 3.3 04/23/2007 14:10:00 8.3 1.2 11.1 5.3 8.5 1.2 11.5 5.3 8.1 1 10.7 5.7 64 8 72 165 3.5 0.1 3.5 3 04/23/2007 14:20:00 8.5 1.4 12.6 4.9 8.7 1.5 13 4.9 8.3 1.3 11.8 4.2 67 9 68 165 3.5 0.1 3.8 3 04/23/2007 14:30:00 9.1 1.2 11.5 5.7 9.3 1.3 11.8 5.7 8.9 1.1 11.5 6.1 64 8 54 165 3.5 0.1 3.8 3.3 04/23/2007 14:40:00 8.8 1.3 13 4.9 9 1.3 13.3 5.3 8.6 1.2 12.6 4.9 65 9 79 165 3.5 0.1 3.8 3 04/23/2007 14:50:00 9 1.3 12.6 5.7 9.3 1.3 13 6.1 8.7 1.2 12.2 5.3 66 8 63 165 3.4 0.1 3.5 2.8 04/23/2007 15:00:00 9.2 1.2 12.6 6.5 9.4 1.3 13 6.1 8.9 1.2 11.8 6.5 71 9 75 165 3.3 0.1 3.5 2.8 04/23/2007 15:10:00 8.3 1.5 11.8 5.3 8.7 1.5 11.8 5.7 8.1 1.4 11.1 4.9 81 8 90 165 3.4 0.1 3.5 2.8 04/23/2007 15:20:00 7.9 1.7 13 4.2 8.2 1.7 13 4.9 7.7 1.4 11.8 4.9 82 10 85 165 3.3 0 3.8 2.8 04/23/2007 15:30:00 9.1 1.2 11.8 6.1 9.5 1.2 12.6 6.1 9 1.2 12.2 6.1 85 6 91 165 3 0.1 3.3 2.6 04/23/2007 15:40:00 10 0.9 11.8 6.8 10.3 1 12.2 7.2 9.6 1.1 11.8 6.8 91 6 87 165 2.6 0.2 3 1.8 04/23/2007 15:50:00 9.5 0.8 11.8 6.8 9.9 0.9 12.2 7.2 9.2 0.9 11.8 5.7 89 5 91 165 2.7 0.2 3 2.1 04/23/2007 16:00:00 9.3 1.1 11.5 4.9 9.8 1.1 11.5 5.7 8.9 1 11.1 5.3 92 6 99 165 2.9 0.1 3.3 2.6 04/23/2007 16:10:00 9.9 0.6 11.5 8 10.3 0.7 11.8 8 9.4 0.8 11.8 7.2 97 5 101 165 2.9 0.1 3.3 2.6 04/23/2007 16:20:00 8.2 0.8 10.7 6.1 8.5 0.8 11.5 6.1 8 0.8 9.5 5.7 98 6 98 165 2.6 0.1 2.8 2.3 04/23/2007 16:30:00 7.1 0.9 8.8 4.2 7.5 0.8 9.5 4.9 6.9 0.8 9.5 4.9 100 6 97 165 2.8 0.1 3.3 2.3 04/23/2007 16:40:00 7.5 0.7 9.1 5.3 7.8 0.6 9.1 5.7 7.4 0.7 9.1 4.6 113 10 107 165 2.7 0.1 3 2.1 04/23/2007 16:50:00 7.4 0.8 9.5 4.6 7.6 0.7 9.5 5.7 7.2 0.8 9.1 4.2 121 5 121 165 2.4 0.2 2.8 1.8 04/23/2007 17:00:00 6.8 0.7 8.8 4.9 7 0.7 9.1 5.3 6.7 0.9 8.8 4.6 121 7 122 165 2.2 0.2 2.6 1.6 04/23/2007 17:10:00 5.9 0.8 7.6 3.8 6.2 0.7 8 4.2 5.9 0.7 7.6 3.8 120 5 125 165 2.3 0.1 2.6 1.8 04/23/2007 17:20:00 5.7 0.5 6.8 4.2 6.1 0.5 7.6 4.6 5.8 0.6 7.6 4.2 118 5 126 165 2.1 0 2.6 1.8 04/23/2007 17:30:00 5.5 0.7 7.2 3.4 6 0.7 7.6 3.8 5.5 0.7 7.2 3 112 6 112 165 2.1 0 2.6 1.8 04/23/2007 17:40:00 6.9 0.8 8.8 4.9 7.3 0.8 9.5 4.9 6.8 0.8 9.5 4.6 107 5 102 165 2.4 0.2 2.8 1.8 04/23/2007 17:50:00 8.3 1 11.8 6.1 8.7 1 12.2 6.5 8.2 0.9 11.5 6.5 110 6 106 165 2.7 0.1 3 2.3 04/23/2007 18:00:00 8.4 0.7 10.3 6.8 8.8 0.6 10.3 7.2 8.2 0.7 9.9 6.5 109 5 116 165 2.8 0 3.3 2.6 04/23/2007 18:10:00 8.3 0.7 10.3 6.5 8.7 0.7 10.7 6.5 8.2 0.8 9.9 5.7 110 5 111 165 2.9 0 3.3 2.8 04/23/2007 18:20:00 8.4 0.8 10.3 5.3 8.7 0.8 11.5 5.7 8 0.8 9.9 5.3 109 5 107 165 3 0 3.3 2.8 04/23/2007 18:30:00 9.4 1.1 11.8 6.8 9.8 1.1 12.6 7.2 9 1.2 11.8 5.7 107 5 105 165 3 0 3.3 2.8 04/23/2007 18:40:00 8.9 0.8 10.7 6.5 9.2 0.8 11.1 7.2 8.5 1 10.7 6.1 107 5 111 165 3 0 3.3 2.6 04/23/2007 18:50:00 8.9 0.9 11.5 6.1 9.3 0.9 11.5 6.8 8.5 1 11.5 5.7 108 5 116 165 3 0.1 3.3 2.6 04/23/2007 19:00:00 9.4 0.9 11.8 6.8 9.8 0.9 12.6 7.2 8.9 1 12.2 6.1 104 5 102 165 3 0.1 3.3 2.6 04/23/2007 19:10:00 9.5 1 12.2 6.8 9.9 1 12.6 7.6 8.8 1 12.2 6.5 101 6 98 165 3.1 0 3.3 2.6 04/23/2007 19:20:00 10.1 0.8 12.2 8 10.5 0.8 12.2 7.6 9.7 1 11.5 6.8 96 6 98 165 3.1 0.1 3.5 2.6 04/23/2007 19:30:00 11.2 0.8 13 8 11.7 0.8 13.7 8.8 10.7 1 13.3 8 96 4 93 165 3.1 0 3.3 2.8 04/23/2007 19:40:00 11.2 0.9 13.3 7.6 11.6 0.9 13.7 8 10.6 1.2 13 6.8 94 5 92 165 3.2 0 3.5 2.8 04/23/2007 19:50:00 10.6 0.9 13.3 7.2 11 0.9 13.3 8 10.1 1 12.2 7.2 95 5 92 165 3.2 0 3.5 2.8 04/23/2007 20:00:00 10.2 0.9 12.6 7.6 10.6 0.9 13.3 8 9.7 1 12.2 6.8 97 5 100 165 3.2 0 3.5 2.8 04/23/2007 20:10:00 10.7 0.8 13.3 7.2 11.2 0.9 13.7 7.2 10.2 1 13.3 7.2 100 5 96 165 3.2 0 3.5 2.8 04/23/2007 20:20:00 10.5 0.8 13 8.4 11 0.8 13.3 8.8 10 1 12.6 7.2 101 5 101 165 3.2 0 3.3 2.8 04/23/2007 20:30:00 10.3 0.8 12.6 7.6 10.7 0.9 13 8 9.9 1 12.6 6.8 103 5 106 165 3.2 0 3.5 2.8 04/23/2007 20:40:00 10.8 1 13.3 7.6 11.1 1.1 13.7 8 10.4 1.1 13.3 7.2 108 5 104 165 3.1 0.1 3.3 2.8 04/23/2007 20:50:00 9.3 1.4 12.2 4.9 9.6 1.4 12.2 5.7 9.1 1.4 11.8 5.3 115 6 105 165 2.9 0.2 3.3 2.3 04/23/2007 21:00:00 9.7 1 12.2 7.2 10 1 12.2 7.2 9.3 1.1 11.8 6.1 108 6 106 165 3 0.1 3.3 2.6 04/23/2007 21:10:00 9.7 1 12.6 6.5 10.1 1 12.6 6.8 9.4 1.1 12.2 6.5 109 6 110 165 3.1 0 3.3 2.8 04/23/2007 21:20:00 9.6 1.1 12.2 6.5 9.9 1 12.6 7.2 9.3 1.1 12.6 6.5 111 7 112 165 3.2 0 3.5 3 04/23/2007 21:30:00 10.1 0.8 12.6 7.6 10.4 0.8 12.6 8.4 9.7 0.9 12.6 7.2 109 5 112 165 3.2 0 3.3 3 04/23/2007 21:40:00 10.3 0.8 12.6 7.6 10.6 0.8 12.6 8 9.8 1 12.2 6.8 109 5 109 165 3.2 0 3.5 3 04/23/2007 21:50:00 10.2 0.9 13 8.4 10.6 0.9 13.7 8.4 9.9 1 12.6 7.6 109 6 114 165 3.2 0 3.5 3 04/23/2007 22:00:00 10 1.5 13 6.5 10.3 1.5 13.3 6.8 9.6 1.6 13 5.7 112 6 102 165 3.1 0 3.3 3 04/23/2007 22:10:00 9.2 0.8 11.1 6.8 9.5 0.8 11.8 6.8 8.8 1 11.5 6.1 107 5 102 165 3.2 0 3.5 3 04/23/2007 22:20:00 9.7 1 12.2 6.8 10 1 12.6 7.2 9.1 1.1 11.5 6.1 108 6 116 165 3.3 0 3.5 3.3 04/23/2007 22:30:00 10.5 1 13.7 7.6 10.9 1 14.1 8 10.1 1.3 13.3 6.8 108 5 102 165 3.3 0 3.5 3.3 04/23/2007 22:40:00 10.6 0.9 13.3 8 10.9 0.9 13.7 8.8 10 1 12.6 7.2 108 5 121 165 3.3 0 3.5 3.3 04/23/2007 22:50:00 10.9 1.1 13.3 6.8 11.2 1.1 13.7 7.2 10.4 1.3 13.7 6.8 112 6 112 165 3.3 0 3.5 3.3 04/23/2007 23:00:00 12.2 1.2 15.6 7.6 12.5 1.1 15.3 8.8 11.7 1.3 15.3 8.8 113 6 122 165 3.3 0 3.5 3.3 04/23/2007 23:10:00 11.4 1.3 15.3 7.6 11.7 1.3 14.9 7.6 10.8 1.5 15.6 7.2 114 7 116 165 3.3 0 3.5 3.3 04/23/2007 23:20:00 11.5 1.5 14.5 7.6 11.8 1.5 14.9 7.6 10.9 1.5 14.5 7.2 114 6 123 165 3.2 0 3.5 2.8 04/23/2007 23:30:00 11.4 1.5 14.5 8 11.7 1.5 14.5 8.4 10.8 1.6 13.7 6.5 112 6 114 165 3.2 0 3.5 2.8 04/23/2007 23:40:00 10.9 1 14.5 8.8 11.2 1 14.5 9.1 10.3 1.2 13 7.2 111 5 110 165 3.2 0 3.5 3 04/23/2007 23:50:00 10.7 1.1 13.3 5.7 11 1.1 13.7 6.5 10 1.2 13 6.1 107 6 103 165 3.3 0 3.5 3 04/24/2007 00:00:00 11 1 13.3 8 11.3 1 14.1 8.4 10.4 1.2 13 6.8 106 5 99 165 3.3 0 3.5 3 04/24/2007 00:10:00 11.3 1.3 14.9 8.4 11.7 1.3 15.6 9.1 10.7 1.5 14.5 7.2 110 6 112 165 3.3 0 3.5 2.8 04/24/2007 00:20:00 11.6 1.2 14.9 7.2 11.9 1.2 15.3 8 11.2 1.3 14.5 6.8 114 6 107 165 3.2 0 3.5 2.8 04/24/2007 00:30:00 10.8 1 14.1 7.6 11.1 1 14.5 8.4 10.3 1 13 7.6 116 6 110 165 3.3 0 3.5 3 04/24/2007 00:40:00 11.7 1.5 15.3 7.6 12 1.5 15.3 8 11.2 1.7 14.9 6.8 112 5 114 165 3.3 0 3.5 2.8 04/24/2007 00:50:00 12.1 1.1 15.3 9.1 12.4 1.1 15.6 9.1 11.5 1.2 14.9 8 108 5 116 165 3.2 0 3.5 3 04/24/2007 01:00:00 11.3 0.8 13.7 8.8 11.6 0.8 13.7 9.5 10.8 0.9 13 8 111 5 109 165 3.2 0 3.5 2.8 04/24/2007 01:10:00 10.4 0.9 12.2 6.8 10.8 0.8 12.6 7.6 10 0.9 12.2 7.2 105 6 107 165 3.2 0 3.5 2.8 04/24/2007 01:20:00 11 1.1 13.3 7.2 11.4 1.1 13.7 7.2 10.4 1.3 13.3 7.2 102 5 108 165 3.2 0 3.3 2.8 04/24/2007 01:30:00 11.4 0.9 13.3 8.4 11.8 0.9 13.7 9.1 10.9 1 13.3 7.2 101 5 102 165 3.2 0 3.3 2.8 04/24/2007 01:40:00 11.5 1 14.1 6.8 11.9 1.1 14.5 6.8 10.9 1.1 13.7 7.2 102 6 104 165 3.1 0 3.3 3 04/24/2007 01:50:00 11 1.1 13.7 7.6 11.3 1.1 13.7 8.4 10.3 1.1 12.6 7.2 101 6 112 165 3.1 0 3.3 2.8 04/24/2007 02:00:00 11.7 1.1 14.1 8 12 1.1 14.9 8.8 11 1.1 13.7 7.6 100 5 98 165 3 0 3.3 2.8 04/24/2007 02:10:00 11.4 0.8 13.3 7.6 11.9 0.8 13.7 8 10.7 1 13.3 7.2 97 5 94 165 3.1 0 3.3 3 04/24/2007 02:20:00 11.7 0.7 13.3 9.5 12.1 0.7 14.1 10.3 11.2 0.9 13.7 8 95 4 93 165 3.2 0 3.3 3 04/24/2007 02:30:00 12 0.8 14.1 9.5 12.5 0.8 14.9 9.9 11.7 1 13.7 8.4 91 3 89 165 3.1 0 3.3 2.8 04/24/2007 02:40:00 12.7 0.8 14.1 9.9 13.2 0.8 14.5 9.9 12.3 1 14.1 9.5 90 3 92 165 3 0 3.3 2.8 04/24/2007 02:50:00 12.1 0.9 13.7 8.8 12.5 1 14.5 9.1 11.5 1 13.3 8 89 4 90 165 3 0 3.3 2.8 04/24/2007 03:00:00 12.3 0.8 13.7 9.1 12.7 0.9 14.1 9.1 11.9 1 13.7 9.1 90 4 90 165 3 0 3.3 2.8 04/24/2007 03:10:00 11.1 1 13 7.6 11.5 1 13.3 8 10.4 1 13 7.6 90 5 103 165 3 0 3.3 2.8 04/24/2007 03:20:00 10.8 1.1 12.6 7.6 11.1 1.1 13.3 8 10.3 1 12.6 7.2 82 6 88 165 3 0 3.3 2.8 04/24/2007 03:30:00 11.6 1.2 14.1 8 12 1.2 14.5 8 11.1 1.2 13.7 8 78 6 83 165 2.9 0 3.3 2.8 04/24/2007 03:40:00 11.9 1 14.1 8 12.3 1 14.5 8.4 11.2 1 13.7 8 87 4 90 165 2.9 0 3 2.8 04/24/2007 03:50:00 11.1 1.2 13.3 6.8 11.4 1.2 13.7 7.6 10.6 1.2 13 6.8 84 5 88 165 2.9 0 3.3 2.3 04/24/2007 04:00:00 10.7 1 13.3 8 11.1 1 13.3 8.8 10.2 1.1 12.6 6.8 83 6 85 165 2.9 0.1 3.3 2.6 04/24/2007 04:10:00 10.9 1 13.3 7.6 11.3 1 13.7 7.6 10.5 1 13 7.6 79 5 79 165 3 0.1 3.3 2.8 04/24/2007 04:20:00 10.5 1 13.3 8 10.9 1 13.7 8.4 10.1 0.9 13 7.6 77 7 83 165 3 0 3.3 2.6 04/24/2007 04:30:00 8.8 1.3 12.2 5.3 9.2 1.3 12.6 5.7 8.6 1.1 11.5 6.1 73 8 78 165 3 0 3.3 2.8 04/24/2007 04:40:00 8 1.1 11.1 5.3 8.4 1.1 11.5 5.7 7.9 1.1 10.3 4.9 71 7 63 165 3 0 3.3 2.8 04/24/2007 04:50:00 8.4 1.1 11.1 5.7 8.7 1.1 11.5 6.1 8.2 1 11.1 5.7 71 7 81 165 3 0 3.3 2.6 04/24/2007 05:00:00 7.7 1.3 10.7 4.2 8 1.3 11.5 4.6 7.6 1.2 11.1 4.2 67 9 78 165 3 0 3.3 2.8 04/24/2007 05:10:00 6.3 1.3 9.9 3.4 6.6 1.2 10.3 3.8 6.3 1.2 9.5 3.4 58 10 65 165 3 0 3.3 2.6 04/24/2007 05:20:00 7.1 1.5 11.5 4.6 7.4 1.5 12.2 4.6 7 1.3 11.1 4.6 56 9 61 165 3 0 3.3 2.6 04/24/2007 05:30:00 7.2 1.2 10.7 4.6 7.5 1.2 11.1 5.3 7 1.2 10.3 4.2 53 10 63 165 2.9 0 3.3 2.6 04/24/2007 05:40:00 7.5 1.3 10.7 4.6 7.7 1.3 11.5 4.9 7.2 1.2 11.1 4.6 55 9 46 165 2.9 0.1 3 2.3 04/24/2007 05:50:00 8.2 1.5 11.8 4.6 8.5 1.5 12.2 4.6 7.9 1.4 11.5 4.9 60 9 68 165 3 0 3.5 2.6 04/24/2007 06:00:00 8 1.2 11.1 5.3 8.2 1.2 11.5 5.7 7.8 1.2 10.7 5.3 64 9 70 165 3.2 0 3.5 2.6 04/24/2007 06:10:00 8.2 1.3 13 4.9 8.5 1.4 12.6 5.3 8.1 1.3 12.6 5.7 64 9 57 165 3.1 0 3.3 2.8 04/24/2007 06:20:00 8.8 1.1 12.2 5.7 9 1.1 12.6 5.7 8.6 1.1 11.8 6.1 65 8 68 165 3 0 3.3 2.8 04/24/2007 06:30:00 7.5 1.2 10.7 4.6 7.9 1.2 11.1 4.9 7.4 1 10.3 4.6 70 7 74 165 3 0 3.3 2.8 04/24/2007 06:40:00 7.8 1.2 10.7 4.9 8.1 1.2 11.1 4.9 7.5 1.1 10.3 4.9 66 7 59 165 3.1 0 3.3 2.8 04/24/2007 06:50:00 7.7 1.1 11.5 5.3 8 1.1 11.8 5.7 7.6 1 10.3 5.3 72 8 73 165 3.2 0 3.5 3 04/24/2007 07:00:00 9 1 12.6 6.8 9.4 1 13 7.2 8.8 1 11.8 6.8 77 5 80 165 3.3 0 3.5 2.8 04/24/2007 07:10:00 7.7 1 10.3 4.6 8.1 1 10.3 5.3 7.7 1 9.9 5.3 74 7 73 165 3.3 0 3.5 3 04/24/2007 07:20:00 8.4 1.4 11.8 5.3 8.8 1.4 12.2 5.7 8.3 1.3 11.8 5.7 78 8 82 165 3.3 0 3.5 3 04/24/2007 07:30:00 9.2 1.2 12.2 6.5 9.6 1.3 12.6 6.8 8.9 1.2 11.8 6.1 78 7 80 165 3.1 0 3.5 2.8 04/24/2007 07:40:00 7.4 1.5 11.1 4.2 7.8 1.5 11.8 4.6 7.4 1.5 11.5 4.6 73 9 88 165 3.3 0 3.5 2.8 04/24/2007 07:50:00 7.7 1.5 12.2 4.9 8.1 1.5 12.6 5.3 7.5 1.3 10.7 4.9 78 8 82 165 3.3 0 3.5 3 04/24/2007 08:00:00 7.9 1.2 11.1 5.3 8.3 1.3 11.5 5.3 7.9 1.2 11.1 4.9 74 8 89 165 3.3 0 3.5 3.3 04/24/2007 08:10:00 8 1.1 10.7 5.3 8.4 1.1 11.1 5.7 8 1.2 11.8 5.3 74 8 78 165 3.2 0 3.5 3 04/24/2007 08:20:00 8.2 1.3 11.1 5.7 8.6 1.3 11.8 5.7 8.1 1.2 10.7 4.9 77 8 77 165 3.2 0 3.5 2.8 04/24/2007 08:30:00 8.1 1.3 11.1 4.9 8.5 1.3 11.1 5.7 8.1 1.2 10.7 5.7 80 7 84 165 3.2 0 3.5 2.6 04/24/2007 08:40:00 6.6 0.9 8.8 4.6 7 0.9 9.1 4.9 6.6 0.8 8.8 4.6 67 8 61 165 3.2 0 3.5 2.6 04/24/2007 08:50:00 7.3 1.1 9.9 4.6 7.7 1.1 10.3 5.3 7.2 1.1 9.9 4.2 65 9 62 165 3.3 0 3.5 2.8 04/24/2007 09:00:00 7 1.4 10.3 3.8 7.3 1.4 10.7 3.8 6.9 1.3 10.3 3.8 65 9 73 165 3.3 0 3.5 2.8 04/24/2007 09:10:00 6.8 1.7 10.7 2.6 7.1 1.7 11.1 3 6.7 1.3 10.3 3.4 59 10 62 165 3.3 0 3.5 2.8 04/24/2007 09:20:00 5.3 1.1 8.8 3 5.6 1.1 9.1 3 5.3 1 8.4 3 53 11 74 165 3.2 0 3.5 2.8 04/24/2007 09:30:00 7 1.7 11.5 3.4 7.2 1.7 11.8 3.4 7.1 1.4 11.8 3 52 10 50 165 3 0 3.3 2.8 04/24/2007 09:40:00 7.5 1.5 11.5 4.2 7.7 1.5 11.8 4.2 7.3 1.3 11.1 4.2 63 11 63 165 3.1 0 3.3 2.6 04/24/2007 09:50:00 8.4 1.4 11.8 4.9 8.7 1.4 12.2 5.3 8.4 1.2 11.5 5.3 65 9 71 165 3.1 0 3.3 2.8 04/24/2007 10:00:00 7.3 1.3 10.3 4.2 7.5 1.2 10.3 4.2 7.3 1.1 9.9 4.9 65 9 48 165 3.1 0 3.3 2.6 04/24/2007 10:10:00 8.1 1.2 11.5 5.3 8.4 1.2 11.5 5.7 8.1 1.2 11.5 5.3 70 8 81 165 3.2 0 3.5 2.8 04/24/2007 10:20:00 6.4 1.2 9.1 3 6.8 1.2 9.9 3.4 6.6 1 9.1 4.2 66 9 65 165 3.2 0 3.5 2.6 04/24/2007 10:30:00 6.5 1.3 9.9 3.8 6.8 1.2 9.9 4.2 6.6 1.1 9.9 4.2 58 10 63 165 3.2 0 3.5 2.8 04/24/2007 10:40:00 6.7 1.2 9.1 4.2 7 1.2 9.9 4.2 6.7 1 9.9 4.2 59 9 64 165 3.2 0 3.5 3 04/24/2007 10:50:00 5.6 1.1 8.8 3 6 1.1 8.8 3.4 5.8 1.1 8.8 3.4 57 10 54 165 3.2 0 3.5 3 04/24/2007 11:00:00 5.2 1.6 10.3 1.9 5.6 1.6 10.7 1.5 5.3 1.5 10.7 1.5 56 12 72 165 3.2 0 3.5 3 04/24/2007 11:10:00 6.5 1.4 9.5 3.4 6.8 1.4 9.9 4.2 6.6 1.2 9.5 3.8 57 11 61 165 3.2 0 3.3 3 04/24/2007 11:20:00 4.5 0.8 6.8 3 4.9 0.9 7.2 3 4.7 0.8 7.2 2.6 49 10 41 165 3.1 0 3.3 2.8 04/24/2007 11:30:00 5.3 1 7.6 3 5.6 1 8 3 5.3 1 7.2 3 44 6 43 165 3 0 3.3 2.8 04/24/2007 11:40:00 6.1 1.3 9.1 2.3 6.4 1.3 9.5 2.6 6.2 1.2 9.1 3.4 50 9 74 165 3.1 0 3.3 2.8 04/24/2007 11:50:00 5.7 1.5 9.9 3 6 1.5 9.5 3.4 5.9 1.3 9.1 3 57 12 52 165 3.2 0 3.3 3 04/24/2007 12:00:00 7.7 1.3 10.7 3.8 8 1.3 11.1 4.2 7.7 1.2 10.7 4.2 61 8 66 165 3.1 0.1 3.5 2.8 04/24/2007 12:10:00 7.3 1.2 9.9 3.4 7.6 1.3 9.9 3.4 7.4 1.1 9.9 4.6 64 8 58 165 2.9 0 3 2.8 04/24/2007 12:20:00 7.2 1.2 9.9 4.2 7.4 1.3 10.3 4.6 7.1 1.2 9.5 4.2 58 8 60 165 2.7 0 3 2.3 04/24/2007 12:30:00 6.4 1.2 9.5 3.8 6.6 1.2 9.9 3.8 6.5 1.1 9.9 4.2 54 10 48 165 3 0.1 3.3 2.6 04/24/2007 12:40:00 6.7 1.7 10.7 3.4 7 1.6 11.1 3.8 6.9 1.5 10.3 4.2 61 10 58 165 3.2 0 3.5 3 04/24/2007 12:50:00 7 1.2 9.9 3.8 7.4 1.1 10.7 4.6 7 1.1 9.5 4.2 67 8 75 165 3.1 0 3.3 2.8 04/24/2007 13:00:00 6.7 1.5 9.5 3.4 7.1 1.5 9.5 3.8 6.8 1.5 9.5 3.8 58 9 63 165 3 0.1 3.3 2.6 04/24/2007 13:10:00 7.2 1.2 9.9 3.8 7.5 1.2 9.9 4.2 7.4 1 9.5 4.9 65 11 53 165 3.2 0 3.5 2.8 04/24/2007 13:20:00 5.7 1 8.4 3.8 6.1 1 9.1 3.8 5.9 0.9 8.8 3.8 63 11 61 165 3.3 0 3.5 2.8 04/24/2007 13:30:00 5.7 1.1 8.8 2.6 6.2 1.2 9.1 2.6 6 1 9.1 3.4 70 8 75 165 3.4 0 3.8 2.8 04/24/2007 13:40:00 6.3 1.1 8.4 3.8 6.7 1.1 9.1 4.2 6.5 1 8.8 4.2 58 8 57 165 3.5 0.1 3.5 3 04/24/2007 13:50:00 6.1 1.1 9.1 3.4 6.5 1.1 9.5 3.8 6.4 1 8.8 3.4 62 9 56 165 3.4 0.1 3.5 2.6 04/24/2007 14:00:00 5.4 1.1 8.8 3.8 5.8 1.1 9.1 3.4 5.7 1.1 8.8 3.4 62 9 63 165 3.4 0.1 3.5 2.6 04/24/2007 14:10:00 5.8 1.2 8.4 3 6.2 1.2 9.1 3 6.1 1.2 8.8 3.8 61 8 58 165 3.2 0 3.5 2.6 04/24/2007 14:20:00 5.2 1 7.6 2.6 5.5 1 8 3 5.4 0.8 7.6 3.4 63 10 49 165 3.2 0 3.5 2.6 04/24/2007 14:30:00 4.5 1 7.6 2.6 4.9 1.1 8.4 2.6 4.8 1.1 8 2.6 77 15 95 165 3.3 0.1 3.5 2.6 04/24/2007 14:40:00 5.1 0.7 7.2 3 5.7 0.8 8 3.4 5.5 0.7 7.6 3.8 91 9 92 165 3.3 0 3.5 2.6 04/24/2007 14:50:00 5 0.8 6.5 2.6 5.5 0.8 6.8 3 5.4 0.8 7.2 3.4 71 9 68 165 3.2 0.1 3.5 2.3 04/24/2007 15:00:00 4.1 0.6 5.3 2.3 4.5 0.7 6.1 2.3 4.4 0.7 6.5 2.6 74 9 83 165 3.2 0 3.5 2.8 04/24/2007 15:10:00 5.2 0.9 6.8 2.6 5.7 1 7.2 3 5.4 1 7.6 3 89 7 88 165 3.2 0.1 3.5 2.8 04/24/2007 15:20:00 5.3 0.6 6.5 3.4 5.9 0.6 7.2 3.8 5.7 0.6 7.2 3.8 90 7 84 165 3 0 3.3 2.8 04/24/2007 15:30:00 4.6 0.7 6.1 3 5.1 0.8 6.8 3 4.8 0.6 6.5 3 85 6 84 165 3 0 3.3 2.8 04/24/2007 15:40:00 4 0.5 5.7 2.6 4.4 0.5 5.7 3 4.3 0.5 5.3 3 77 8 68 165 3 0 3.3 2.8 04/24/2007 15:50:00 4 0.7 6.1 2.6 4.4 0.8 6.5 3 4.3 0.7 6.1 3 74 9 84 165 3 0 3.3 2.8 04/24/2007 16:00:00 4.1 0.6 5.7 3 4.4 0.6 6.1 3 4.2 0.6 6.1 2.6 71 7 77 165 3 0 3.3 2.8 04/24/2007 16:10:00 3.7 0.5 4.9 2.3 4 0.6 5.3 2.3 3.8 0.6 5.3 1.9 66 10 78 165 3 0 3.3 2.8 04/24/2007 16:20:00 3.5 0.5 4.9 2.3 3.7 0.6 5.3 2.6 3.7 0.5 5.3 2.6 63 7 56 165 3 0 3.3 2.8 04/24/2007 16:30:00 3.6 0.6 4.9 2.3 3.8 0.7 5.7 2.3 3.8 0.6 5.3 1.9 75 10 96 165 3 0 3.3 2.8 04/24/2007 16:40:00 3.2 0.7 4.6 1.5 3.3 0.7 5.3 1.9 3.3 0.6 4.9 2.3 58 9 84 165 3 0 3.3 2.8 04/24/2007 16:50:00 2.9 0.5 4.2 1.9 2.9 0.6 4.6 1.9 2.9 0.6 4.2 1.9 63 10 65 165 3 0 3.3 2.8 04/24/2007 17:00:00 4 0.8 5.7 2.3 4.3 0.8 6.1 2.3 4.2 0.8 5.7 1.9 83 7 79 165 3.1 0 3.3 2.8 04/24/2007 17:10:00 4.2 0.7 5.3 2.3 4.5 0.7 6.1 2.6 4.3 0.7 5.7 2.3 94 6 94 165 3.2 0 3.3 3 04/24/2007 17:20:00 4.6 0.5 5.7 2.6 5 0.6 6.5 3.4 4.6 0.6 6.1 3 100 6 98 165 3.2 0 3.5 3 04/24/2007 17:30:00 6.6 1 8.8 3.4 7 1 9.1 3.8 6.8 1 9.1 3 112 8 100 165 3.2 0.1 3.5 2.8 04/24/2007 17:40:00 5.8 0.6 7.2 3.8 6.3 0.6 7.6 4.2 5.9 0.7 7.6 3.8 111 5 107 165 3.1 0 3.3 2.8 04/24/2007 17:50:00 5.5 0.7 7.2 3.8 6 0.7 7.6 4.2 5.7 0.8 7.2 3.4 101 7 102 165 3.1 0 3.3 2.8 04/24/2007 18:00:00 6.4 0.8 7.6 3.4 6.9 0.8 8.4 4.2 6.4 0.8 8 4.2 99 6 92 165 3.2 0 3.5 2.8 04/24/2007 18:10:00 5.8 0.7 7.2 3.4 6.4 0.7 8 3.8 6 0.7 7.6 3.8 100 4 99 165 3 0.1 3.3 2.8 04/24/2007 18:20:00 5.1 0.6 6.1 3.4 5.7 0.6 6.8 4.2 5.2 0.6 6.5 3.4 99 5 98 165 3 0 3.3 2.8 04/24/2007 18:30:00 5.3 0.6 6.8 3.8 5.8 0.6 7.6 3.8 5.4 0.6 7.2 3.8 95 6 94 165 3.1 0 3.3 2.6 04/24/2007 18:40:00 6.5 0.7 7.6 4.2 7.1 0.7 8 4.6 6.5 0.7 8 4.2 96 5 104 165 3.1 0.1 3.3 2.6 04/24/2007 18:50:00 6.5 0.6 8 4.6 7 0.6 8.4 4.9 6.4 0.6 7.6 4.6 100 5 102 165 3 0 3.3 2.8 04/24/2007 19:00:00 6.7 0.7 8 4.2 7.2 0.7 8.8 4.2 6.8 0.7 8.8 5.3 98 4 92 165 3 0 3.3 2.8 04/24/2007 19:10:00 6.7 0.5 8 4.6 7.2 0.5 8.4 4.9 6.7 0.7 8 4.2 98 4 99 165 2.9 0 3.3 2.6 04/24/2007 19:20:00 6.1 0.5 7.2 4.9 6.7 0.5 8 5.3 6.2 0.6 7.6 4.6 94 5 92 165 2.9 0 3 2.6 04/24/2007 19:30:00 5.8 0.6 7.6 4.2 6.4 0.6 8 4.6 6 0.6 7.2 4.6 93 6 97 165 2.9 0 3 2.6 04/24/2007 19:40:00 5.1 0.6 6.5 3.8 5.8 0.6 7.2 4.2 5.4 0.6 6.8 3.8 90 6 91 165 2.9 0 3 2.6 04/24/2007 19:50:00 4.6 0.7 6.1 3 5.2 0.8 6.8 3.4 5 0.7 6.8 3.4 89 7 91 165 2.9 0 3 2.6 04/24/2007 20:00:00 4.8 0.5 6.1 3.4 5.5 0.6 6.5 4.2 5.2 0.5 6.5 4.2 89 5 88 165 2.8 0 3 2.6 04/24/2007 20:10:00 4.9 0.6 6.1 3 5.5 0.7 6.5 3.4 5.2 0.6 6.5 3.4 89 5 92 165 2.7 0 2.8 2.6 04/24/2007 20:20:00 4.4 0.5 5.7 3 4.9 0.6 6.5 3.4 4.7 0.6 6.1 3.4 83 7 84 165 2.6 0.1 2.8 2.3 04/24/2007 20:30:00 5.4 1 8.8 3 5.9 1 8.8 3.8 5.5 0.9 8.4 3.8 92 13 99 165 2.7 0.1 3 2.3 04/24/2007 20:40:00 8.3 1.2 10.3 4.2 8.5 1.1 10.3 4.9 8.1 1.2 10.3 4.6 119 8 121 165 2.9 0 3 2.6 04/24/2007 20:50:00 8.2 1 11.8 5.3 8.3 1 12.2 5.3 8 1 12.6 5.7 122 8 114 165 2.7 0 2.8 2.6 04/24/2007 21:00:00 9.5 0.9 11.8 6.8 9.6 1 11.8 7.2 9.2 0.9 11.8 7.2 128 6 123 165 2.7 0 2.8 2.6 04/24/2007 21:10:00 9.9 1.2 13 6.8 10 1.2 13 7.2 9.7 1.2 12.2 5.7 127 6 126 165 2.7 0 3 2.6 04/24/2007 21:20:00 9.9 1 12.2 6.8 10 1 12.2 7.6 9.7 1 11.5 6.8 128 5 129 165 2.6 0.1 2.8 2.3 04/24/2007 21:30:00 9.6 1 12.2 6.5 9.6 1 12.6 6.1 9.2 1 11.1 6.1 130 6 121 165 2.5 0 2.8 2.3 04/24/2007 21:40:00 10.5 1 12.6 6.8 10.5 1 13 6.8 10.3 1 12.6 6.8 134 7 137 165 2.6 0 2.8 2.3 04/24/2007 21:50:00 10.3 1 13 6.8 10.3 1 13 7.2 10 1 12.2 7.2 135 8 135 165 2.6 0 2.8 2.6 04/24/2007 22:00:00 10.3 0.9 12.6 8 10.4 0.9 12.2 7.6 10.1 0.9 12.6 7.2 133 5 143 165 2.6 0 3 2.3 04/24/2007 22:10:00 9.8 1 12.6 6.1 9.8 1 12.6 6.5 9.4 1.1 11.8 6.1 129 6 128 165 2.6 0 2.8 2.1 04/24/2007 22:20:00 9 0.8 10.7 6.5 9.1 0.7 11.1 6.8 8.9 0.7 10.3 6.8 126 6 128 165 2.6 0 2.8 2.3 04/24/2007 22:30:00 9.6 1 11.8 7.2 9.8 1 12.2 7.2 9.5 0.9 11.8 7.2 124 6 122 165 2.7 0 2.8 2.1 04/24/2007 22:40:00 9.7 0.8 12.2 7.2 9.8 0.8 12.2 7.6 9.5 0.8 12.2 7.2 126 6 130 165 2.7 0 2.8 2.1 04/24/2007 22:50:00 9.6 1 12.2 7.2 9.9 1 12.2 8 9.4 1 12.2 7.2 124 5 128 165 2.7 0 2.8 2.3 04/24/2007 23:00:00 10.6 1.2 13.3 7.2 10.7 1.2 13.3 7.6 10.4 1.2 13.3 7.2 133 7 126 165 2.7 0 3 1.8 04/24/2007 23:10:00 9.5 1.1 12.2 6.8 9.6 1 12.2 7.2 9.3 1.1 12.2 6.1 131 7 129 165 2.6 0 2.8 2.3 04/24/2007 23:20:00 9.4 0.9 11.5 6.5 9.5 0.9 11.8 6.5 9.3 0.9 11.8 6.8 130 6 120 165 2.5 0 2.8 2.3 04/24/2007 23:30:00 10.3 1.5 13.7 7.6 10.3 1.5 13.7 7.6 10.1 1.5 13.7 6.5 137 9 128 165 2.5 0.1 2.8 2.3 04/24/2007 23:40:00 9.9 1.6 13.7 6.8 10 1.5 13.7 7.2 9.5 1.5 13.7 6.1 131 11 130 165 2.6 0 2.8 2.1 04/24/2007 23:50:00 11.6 1.2 14.5 7.6 11.6 1.1 14.5 7.6 11.4 1.2 14.5 7.2 134 7 146 165 2.6 0 2.8 1.8 04/25/2007 00:00:00 11 1.1 14.5 8.4 11 1 14.5 8.4 10.6 1.1 13.7 7.2 129 7 119 165 2.6 0.1 2.8 1.8 04/25/2007 00:10:00 10.5 1 13 7.6 10.6 1 13.3 8 10.1 1.1 13 7.2 128 7 130 165 2.6 0.1 2.8 1.8 04/25/2007 00:20:00 10.8 1.1 14.1 8.4 10.9 1.1 13.7 8.4 10.6 1.2 13.3 7.2 130 7 125 165 2.6 0 2.8 2.6 04/25/2007 00:30:00 11.7 1 14.5 8 11.8 1 14.9 8.4 11.5 1 14.5 7.6 131 7 125 165 2.6 0 2.8 2.3 04/25/2007 00:40:00 12.3 1.1 14.5 9.5 12.4 1.1 14.9 9.5 12.1 1.1 14.9 8.8 129 6 129 165 2.6 0 2.8 2.6 04/25/2007 00:50:00 11.4 0.9 13.7 9.1 11.6 0.8 14.1 9.5 11.3 0.9 14.1 8.8 126 6 126 165 2.5 0 2.8 2.3 04/25/2007 01:00:00 12 1 14.5 9.1 12.1 1 14.9 9.1 11.6 1 14.1 9.5 128 6 127 165 2.5 0 2.8 2.3 04/25/2007 01:10:00 12.1 1.1 15.3 9.5 12.2 1.1 15.3 9.1 11.8 1 14.9 8.8 126 7 129 165 2.6 0 2.8 2.3 04/25/2007 01:20:00 11.2 1.2 14.5 8 11.3 1.1 14.9 8 10.9 1.2 14.5 7.2 126 7 134 165 2.6 0 2.8 2.6 04/25/2007 01:30:00 11.7 0.9 14.9 9.5 11.8 0.9 14.5 9.5 11.4 1 14.1 9.1 124 6 121 165 2.7 0 2.8 2.6 04/25/2007 01:40:00 11.5 1.2 14.5 8.8 11.6 1.2 14.5 9.1 11.2 1.3 15.3 7.6 123 6 121 165 2.7 0 2.8 2.6 04/25/2007 01:50:00 11.6 1.5 16.4 8.8 11.8 1.5 16.8 8.8 11.3 1.5 15.3 8 124 8 125 165 2.7 0 3 2.6 04/25/2007 02:00:00 12.2 1.3 15.3 9.5 12.3 1.4 15.6 9.1 11.9 1.4 14.9 8.8 128 6 124 165 2.7 0 3 2.1 04/25/2007 02:10:00 11.6 1.1 15.3 8 11.7 1.1 15.3 8.4 11.3 1.2 14.9 8 131 7 136 165 2.8 0.1 3 2.1 04/25/2007 02:20:00 13.1 1.7 16.8 8.8 13.1 1.7 17.2 8.4 12.7 1.8 17.2 8.8 131 7 125 165 2.8 0 3 2.1 04/25/2007 02:30:00 13.5 1.2 17.2 8.8 13.6 1.3 17.6 9.5 13.3 1.4 19.1 9.1 134 7 118 165 2.7 0 3 2.1 04/25/2007 02:40:00 13.6 1.2 16.1 9.9 13.6 1.2 16.1 9.9 13.3 1.5 16.4 9.5 136 7 135 165 2.7 0 2.8 2.1 04/25/2007 02:50:00 12.9 1.3 15.6 8.8 13 1.3 15.6 8.8 12.6 1.3 16.1 9.5 137 7 134 165 2.6 0 2.8 1.8 04/25/2007 03:00:00 12.5 1.1 15.3 9.9 12.5 1.1 15.3 9.9 12.2 1.1 14.9 9.5 138 8 138 165 2.6 0.1 2.8 1.8 04/25/2007 03:10:00 12.1 1 16.1 9.1 12.1 1 16.1 9.5 11.8 1.2 15.3 8.4 138 7 133 165 2.6 0 2.8 1.8 04/25/2007 03:20:00 11.4 1.1 13.7 6.8 11.5 1.1 13.7 7.6 11.1 1.1 14.1 8 135 8 129 165 2.6 0.1 2.8 1.8 04/25/2007 03:30:00 12.2 1.1 14.9 9.9 12.3 1.1 15.3 9.5 11.9 1.3 15.3 8.4 133 6 133 165 2.6 0.1 2.8 1.8 04/25/2007 03:40:00 12.5 1.2 15.6 9.5 12.5 1.2 15.6 9.5 12 1.3 15.3 8.4 133 7 128 165 2.6 0.1 2.8 1.8 04/25/2007 03:50:00 13 1.1 15.6 9.9 13 1.2 15.6 9.9 12.6 1.1 15.3 9.1 137 6 128 165 2.5 0.1 2.8 2.1 04/25/2007 04:00:00 11.8 1.3 14.5 8.8 11.8 1.3 14.1 8.8 11.6 1.3 14.9 8.4 139 7 139 165 2.4 0 2.6 2.1 04/25/2007 04:10:00 12.9 1.2 15.6 9.9 12.9 1.2 15.3 9.5 12.7 1.2 15.3 9.1 138 6 134 165 2.2 0 2.6 1.8 04/25/2007 04:20:00 11.1 1.3 13.7 8 11.1 1.3 13.7 7.6 11 1.3 14.5 7.2 141 6 136 165 2.2 0 2.6 1.8 04/25/2007 04:30:00 10.9 1.4 14.1 6.5 11 1.4 14.1 6.8 10.5 1.5 13.3 6.5 136 7 136 165 2.4 0.1 2.6 1.8 04/25/2007 04:40:00 11.4 0.8 13.7 8.8 11.5 0.8 14.1 9.1 11.2 0.9 13.7 7.2 140 6 126 165 2.4 0.1 2.8 1.8 04/25/2007 04:50:00 11 0.8 13 9.1 10.9 0.8 13 9.1 10.8 0.9 13.3 8 144 5 142 165 2.4 0 2.6 2.3 04/25/2007 05:00:00 11.5 0.7 13.7 8.8 11.5 0.7 14.1 8.8 11.2 0.8 13.3 8.4 141 7 126 165 2.4 0 2.6 2.3 04/25/2007 05:10:00 12.3 1 14.1 9.5 12.2 1 14.5 9.1 11.9 1.1 14.1 8.4 140 5 136 165 2.4 0 2.6 2.3 04/25/2007 05:20:00 12.3 1.2 16.4 9.5 12.3 1.3 16.4 9.1 12 1.4 17.2 7.6 140 6 140 165 2.4 0 2.6 2.3 04/25/2007 05:30:00 13.2 1 15.6 10.3 13.2 1 16.1 9.9 12.8 1.1 16.1 9.9 139 6 143 165 2.4 0 2.6 2.3 04/25/2007 05:40:00 13 0.9 15.3 10.3 13 0.8 15.6 10.7 12.8 1 14.9 10.3 143 5 141 165 2.4 0 2.6 2.3 04/25/2007 05:50:00 12.9 1.1 15.6 8.8 13 1.1 15.3 9.5 12.8 1 15.6 9.9 141 7 133 165 2.4 0 2.6 2.3 04/25/2007 06:00:00 13.4 1.2 17.2 10.3 13.4 1.2 17.2 10.7 13.1 1.1 16.8 9.9 141 6 135 165 2.4 0 2.6 2.3 04/25/2007 06:10:00 13.1 1.1 15.3 10.3 13.1 1.1 15.6 10.3 12.9 1.1 16.1 9.5 141 7 139 165 2.4 0 2.8 2.3 04/25/2007 06:20:00 13.9 1.1 16.4 10.7 13.9 1.1 16.4 10.7 13.6 1.3 16.8 9.5 142 5 146 165 2.4 0 2.6 2.3 04/25/2007 06:30:00 14 0.9 16.4 11.1 14 0.9 16.1 10.7 13.9 1 16.8 9.9 144 5 138 165 2.4 0 2.6 2.3 04/25/2007 06:40:00 14 0.8 15.6 11.5 13.9 0.7 15.6 11.8 13.7 0.9 16.1 10.3 144 5 139 165 2.4 0 2.6 2.3 04/25/2007 06:50:00 13.3 0.8 15.3 11.1 13.2 0.8 14.9 11.1 13 1 15.6 9.9 146 4 150 165 2.4 0 2.6 2.3 04/25/2007 07:00:00 13.8 0.7 15.3 12.2 13.8 0.7 15.6 11.8 13.6 0.8 15.3 11.5 147 4 153 165 2.3 0 2.6 2.1 04/25/2007 07:10:00 12.7 0.9 14.5 10.3 12.8 0.9 14.5 10.3 12.4 1 14.9 9.1 147 4 149 165 2.3 0 2.6 1.8 04/25/2007 07:20:00 12.9 0.8 14.1 10.7 12.9 0.8 14.5 10.7 12.6 1 14.5 9.5 149 3 149 165 2.3 0 2.6 1.8 04/25/2007 07:30:00 12.1 0.7 13.7 9.5 12.1 0.7 13.7 9.5 11.8 0.8 13.7 9.1 150 3 154 165 2.3 0 2.6 1.8 04/25/2007 07:40:00 11.4 0.5 12.6 9.9 11.4 0.5 12.2 9.5 11.1 0.6 12.6 9.1 147 3 148 165 2.4 0.1 2.8 1.8 04/25/2007 07:50:00 10.9 0.6 12.6 9.1 10.9 0.6 12.2 8.8 10.7 0.7 12.2 8 150 3 153 165 2.7 0 2.8 2.1 04/25/2007 08:00:00 9.9 0.5 11.1 8.4 9.7 0.5 11.5 8.4 9.7 0.6 11.5 8 153 4 147 165 2.6 0.1 2.8 1.8 04/25/2007 08:10:00 8.9 0.5 10.3 7.6 8.8 0.5 10.3 7.6 8.7 0.6 10.3 6.8 151 3 157 165 2.4 0.1 2.6 1.8 04/25/2007 08:20:00 9.1 0.6 10.7 8 9 0.6 10.7 7.6 9 0.6 10.7 7.6 150 3 145 165 2.4 0.1 2.6 1.8 04/25/2007 08:30:00 9.9 0.7 11.8 8 9.8 0.7 11.8 7.6 9.8 0.7 12.2 7.2 147 6 162 165 2.6 0.1 2.8 1.8 04/25/2007 08:40:00 11.4 0.8 13.3 9.5 11.4 0.8 13.7 9.5 11.2 0.8 13 8.8 149 3 142 165 2.7 0 2.8 2.3 04/25/2007 08:50:00 10.8 0.6 12.2 9.1 10.9 0.6 12.2 9.1 10.7 0.7 12.2 8.4 149 3 151 165 2.7 0 2.8 2.3 04/25/2007 09:00:00 10.6 0.5 12.2 9.1 10.6 0.6 12.6 9.1 10.4 0.6 12.2 8.8 147 3 148 165 2.7 0 2.8 2.3 04/25/2007 09:10:00 11.1 0.6 12.6 9.1 11.1 0.6 12.6 9.5 10.9 0.6 12.2 8.8 147 3 147 165 2.7 0 2.8 2.3 04/25/2007 09:20:00 10.4 0.7 12.2 8.4 10.4 0.8 12.2 8.4 10.2 0.7 11.8 7.6 145 4 145 165 2.7 0 3 2.3 04/25/2007 09:30:00 9.3 0.6 10.7 8 9.3 0.6 10.7 7.6 9.1 0.6 10.7 7.2 147 4 147 165 2.7 0 3 2.3 04/25/2007 09:40:00 9.6 0.5 10.7 8.4 9.5 0.5 10.7 8.4 9.3 0.6 10.7 7.6 143 5 135 165 2.8 0.1 3 2.3 04/25/2007 09:50:00 9.4 0.5 10.3 8 9.4 0.5 10.3 7.6 9.2 0.5 10.7 7.6 145 4 145 165 2.8 0 3 2.3 04/25/2007 10:00:00 8.8 1.1 11.5 6.8 8.8 1.1 11.5 6.8 8.5 1.1 11.1 6.1 141 8 158 165 2.8 0 3 2.3 04/25/2007 10:10:00 10.5 0.8 13 8.8 10.5 0.8 12.6 8.4 10.3 0.8 12.6 8 140 6 128 165 2.9 0 3.3 2.6 04/25/2007 10:20:00 9.4 1 12.2 7.2 9.4 0.9 12.2 7.2 9 1 11.5 6.5 136 8 135 165 3 0 3.3 2.6 04/25/2007 10:30:00 10.2 1 13 6.8 10.2 1 12.6 7.6 9.7 1 11.8 6.8 135 6 137 165 3.2 0 3.3 3 04/25/2007 10:40:00 12.2 1.1 15.6 7.6 12.2 1.1 15.3 7.6 11.7 1.1 14.1 7.6 133 7 121 165 3.2 0 3.3 2.8 04/25/2007 10:50:00 12.3 1.2 14.9 9.5 12.3 1.2 15.3 9.5 11.8 1.3 14.9 8 131 8 134 165 3.2 0 3.5 3 04/25/2007 11:00:00 11.4 1.2 13.7 8.4 11.4 1.2 13.7 8.4 11 1.1 14.1 7.6 129 8 127 165 3.2 0.2 3.5 2.6 04/25/2007 11:10:00 11.8 1.1 14.5 8.4 11.8 1.1 14.9 9.1 11.3 1.3 14.5 7.6 123 8 110 165 3.2 0.1 3.3 2.3 04/25/2007 11:20:00 11.8 1.5 15.3 8 11.8 1.5 15.3 8 11.3 1.6 14.9 6.8 128 9 127 165 2.9 0 3.3 2.6 04/25/2007 11:30:00 12.4 1.2 15.3 8.8 12.5 1.2 15.3 8.4 12 1.4 15.6 8.4 115 8 102 165 2.3 0.2 3 1.8 04/25/2007 11:40:00 9.9 1.1 12.6 7.2 10.1 1.1 13 7.6 9.4 1 12.2 7.2 109 7 96 165 2.2 0.2 2.8 1.8 04/25/2007 11:50:00 9.6 1.1 11.8 6.5 9.8 1 12.2 6.5 9.1 1 11.8 6.5 115 6 114 165 2.9 0.1 3.3 2.6 04/25/2007 12:00:00 9.7 1.1 12.2 6.8 9.9 1.1 12.6 7.2 9.3 1.1 12.2 6.8 116 6 122 165 3.2 0 3.5 2.6 04/25/2007 12:10:00 9.5 1.3 12.6 5.7 9.8 1.3 13 6.5 9.3 1.3 12.2 5.7 114 9 119 165 3.2 0 3.5 2.8 04/25/2007 12:20:00 9.2 1 12.6 6.8 9.5 1 13 7.2 8.8 1 11.5 6.1 112 8 120 165 3.1 0.1 3.5 2.3 04/25/2007 12:30:00 8.4 1.3 11.5 4.9 8.7 1.3 11.8 5.7 8 1.2 11.1 4.9 102 6 102 165 3.1 0.1 3.3 2.6 04/25/2007 12:40:00 8.9 1 11.1 5.7 9.2 1 11.1 6.5 8.4 1.1 11.1 5.7 101 8 104 165 3 0.1 3.3 2.6 04/25/2007 12:50:00 9.8 1 12.6 6.8 10.1 1.1 13 6.8 9.4 1.2 12.6 5.3 101 7 88 165 3 0 3.3 2.6 04/25/2007 13:00:00 10.3 1.1 13 7.6 10.6 1.2 13.3 8 9.7 1.2 13 6.5 101 7 102 165 2.9 0 3.3 2.6 04/25/2007 13:10:00 10.3 1.1 13.3 6.1 10.7 1.1 14.1 6.5 9.9 1.3 13.3 4.9 101 6 102 165 3 0.1 3.3 2.6 04/25/2007 13:20:00 9.8 1.2 12.6 6.8 10.1 1.2 13 7.2 9.3 1.1 11.5 6.5 100 7 102 165 3 0.1 3.3 2.3 04/25/2007 13:30:00 9.9 1.4 12.6 6.1 10.3 1.4 13 6.5 9.2 1.5 12.2 5.3 98 6 96 165 3 0.1 3.3 2.6 04/25/2007 13:40:00 9.4 1.2 12.2 5.3 9.7 1.2 12.6 5.7 8.9 1.1 11.5 5.7 101 7 91 165 3 0.1 3.3 2.6 04/25/2007 13:50:00 10.5 1.2 13 6.1 10.8 1.2 13.3 6.5 10 1.4 13 6.5 103 6 104 165 3 0 3.3 2.6 04/25/2007 14:00:00 10 2 13.3 5.7 10.3 2 13.7 6.1 9.4 1.9 13 5.7 105 9 103 165 3 0.1 3.3 2.6 04/25/2007 14:10:00 11.1 1.2 14.1 8 11.4 1.2 14.1 8.4 10.5 1.4 13.7 6.1 105 5 105 165 3 0 3.3 2.8 04/25/2007 14:20:00 10.2 1.3 12.6 6.8 10.5 1.3 13 7.2 9.6 1.5 12.6 5.7 105 6 103 165 3 0 3.3 2.8 04/25/2007 14:30:00 10.3 1.2 14.1 7.6 10.6 1.2 14.1 8 9.6 1.3 13 6.5 104 7 106 165 3 0 3.3 2.8 04/25/2007 14:40:00 10.9 1.3 13.7 6.5 11.2 1.3 14.1 6.8 10.2 1.3 13.3 6.1 98 7 99 165 2.9 0 3.3 2.8 04/25/2007 14:50:00 10.8 1.3 13.7 7.2 11.2 1.3 14.1 7.6 10.3 1.3 13 6.8 94 6 89 165 2.9 0 3 2.8 04/25/2007 15:00:00 10.5 1.1 13.3 7.2 10.9 1.1 13.3 7.6 9.9 1.2 12.6 6.1 91 7 75 165 2.9 0 3 2.6 04/25/2007 15:10:00 10.3 1.1 13 6.8 10.7 1.1 13 7.2 9.9 1 12.6 6.8 84 6 74 165 2.9 0 3 2.6 04/25/2007 15:20:00 10.5 1.3 13 6.5 10.9 1.3 13 6.8 10.4 1.1 13 6.8 83 6 89 165 2.9 0 3 2.6 04/25/2007 15:30:00 10.1 1.3 13.3 6.8 10.5 1.3 13.7 7.6 9.7 1.2 13 6.8 85 6 91 165 2.7 0 3 2.6 04/25/2007 15:40:00 11.4 1.1 13.3 8 11.7 1.1 14.1 8.8 10.9 1.1 13.3 7.6 84 6 94 165 2.8 0 3 2.6 04/25/2007 15:50:00 11.8 0.9 13.3 9.1 12.2 1 13.7 9.1 11.2 1.1 13.3 8 90 4 91 165 2.9 0 3 2.8 04/25/2007 16:00:00 11.6 1.1 14.1 8.8 12 1.1 14.1 8.8 11 1.2 13.7 8 91 5 87 165 2.9 0 3 2.6 04/25/2007 16:10:00 10.1 1 13 6.8 10.5 1.1 13 6.8 9.7 1.1 12.6 6.8 89 7 99 165 2.9 0.1 3 2.3 04/25/2007 16:20:00 10.7 1.3 13.3 6.8 11.1 1.3 13.7 7.2 10.2 1.2 13 6.5 86 6 88 165 2.7 0 3 2.6 04/25/2007 16:30:00 11.6 1.5 14.5 7.6 11.9 1.6 15.3 7.2 10.9 1.5 14.5 7.2 89 6 79 165 2.5 0.1 2.8 1.8 04/25/2007 16:40:00 12.3 0.9 14.5 9.5 12.7 0.9 14.9 9.5 11.7 1 14.1 8.8 94 6 94 165 2.1 0.1 2.6 1.6 04/25/2007 16:50:00 10.9 1.2 13.7 7.2 11.2 1.3 14.1 7.6 10.2 1.2 13 6.8 92 6 102 165 2.2 0.2 2.8 1.8 04/25/2007 17:00:00 10.3 1 12.6 7.6 10.7 1.1 13 8 9.8 1.1 11.8 6.5 92 6 88 165 2.4 0.1 3 2.1 04/25/2007 17:10:00 11.4 1.1 14.1 8.8 11.7 1.1 14.5 8.8 10.7 1.3 13.7 7.2 93 6 90 165 2.3 0.1 2.8 1.8 04/25/2007 17:20:00 11.3 1 13.3 8.4 11.6 1 13.7 8.8 10.5 1 13 8 90 6 94 165 2.6 0.1 2.8 1.8 04/25/2007 17:30:00 11.5 1.1 13.7 8 11.9 1.1 14.1 8 10.8 1.1 13.3 8 87 5 87 165 2.7 0 3 2.1 04/25/2007 17:40:00 12 1 14.1 9.1 12.4 1 14.5 9.5 11.5 1 13.7 9.1 89 5 90 165 2.8 0 3 2.1 04/25/2007 17:50:00 11.2 1.2 14.1 8 11.6 1.2 14.5 8.4 10.7 1.2 14.1 8 89 7 99 165 2.7 0 2.8 1.8 04/25/2007 18:00:00 9.1 1.1 12.2 6.1 9.5 1.1 12.6 6.8 8.8 1 11.5 6.1 82 6 87 165 2.6 0.1 2.8 1.8 04/25/2007 18:10:00 9.8 1.1 13 6.5 10.1 1.2 13.3 6.8 9.2 1.1 11.8 6.5 83 6 84 165 2.4 0 2.8 1.8 04/25/2007 18:20:00 10.4 1.1 12.6 7.2 10.7 1.1 13 7.6 9.8 1 12.2 6.1 82 5 87 165 2.4 0 2.8 2.3 04/25/2007 18:30:00 9.5 1.1 12.2 6.5 9.9 1.2 12.6 7.2 9.2 1.1 12.2 6.1 78 7 83 165 2.5 0 2.8 2.3 04/25/2007 18:40:00 10.1 1.4 13.7 6.5 10.4 1.5 14.1 6.5 9.6 1.4 13.3 6.1 80 8 89 165 2.5 0.1 2.8 2.3 04/25/2007 18:50:00 10.5 1.2 13.7 8 10.8 1.2 14.1 8 10.2 1.2 13.3 7.6 78 7 77 165 2.4 0 2.6 2.3 04/25/2007 19:00:00 10.1 1.2 12.6 6.8 10.5 1.3 13.3 7.2 9.6 1.2 13 6.5 82 7 93 165 2.4 0 2.6 2.1 04/25/2007 19:10:00 8.7 1.3 13 5.3 9 1.3 13 5.7 8.3 1.3 11.8 6.1 79 7 81 165 2.4 0 2.6 2.3 04/25/2007 19:20:00 6.8 1 8.8 4.6 7.2 0.9 9.1 4.9 6.6 1 9.5 4.2 71 8 70 165 2.4 0 2.6 2.3 04/25/2007 19:30:00 6.8 1 9.9 4.9 7.2 0.9 10.3 4.9 6.6 0.9 8.8 4.2 70 9 62 165 2.4 0 2.6 2.3 04/25/2007 19:40:00 7.2 1.2 10.3 4.2 7.5 1.2 10.3 4.9 7 1.2 9.9 3.8 63 8 75 165 2.4 0 2.6 2.3 04/25/2007 19:50:00 7.4 1 9.9 5.3 7.9 1 10.7 5.7 7.2 1 10.7 4.9 69 7 77 165 2.4 0 2.6 2.3 04/25/2007 20:00:00 6.5 1.1 9.9 4.2 7 1.1 10.3 4.2 6.4 1.1 9.9 3.8 62 10 85 165 2.4 0 2.6 2.3 04/25/2007 20:10:00 6.5 1.3 9.9 3.8 6.9 1.3 9.9 4.2 6.2 1.3 9.1 3 56 9 62 165 2.4 0 2.6 2.3 04/25/2007 20:20:00 6.6 1.2 9.5 3.8 6.9 1.2 9.9 4.2 6.3 1.1 9.9 4.2 50 9 58 165 2.4 0 2.6 2.3 04/25/2007 20:30:00 6.6 1.1 10.3 4.2 7 1.1 10.3 4.6 6.5 1.1 9.5 3.4 49 10 49 165 2.4 0 2.6 2.3 04/25/2007 20:40:00 7.2 1.3 11.1 4.6 7.6 1.3 11.1 5.3 7 1.3 10.7 4.2 58 9 53 165 2.6 0 2.8 2.3 04/25/2007 20:50:00 8 1.3 12.6 4.9 8.3 1.3 13 4.9 7.7 1.4 13 4.2 59 9 59 165 2.6 0 2.8 2.1 04/25/2007 21:00:00 8.1 1.3 13 4.2 8.4 1.3 13.7 4.6 7.8 1.1 11.1 4.9 59 11 77 165 2.4 0.2 2.8 1.8 04/25/2007 21:10:00 6.3 1.2 9.9 3.8 6.7 1.2 10.3 4.2 6.2 1.2 9.5 3.8 60 9 53 165 2.4 0.1 2.6 1.8 04/25/2007 21:20:00 7.5 1.3 11.1 4.2 7.8 1.3 11.5 4.6 7.2 1.3 10.3 4.2 66 10 65 165 2.6 0 2.8 2.3 04/25/2007 21:30:00 7.7 1.5 12.6 4.9 8 1.5 12.2 5.3 7.4 1.3 11.8 4.9 59 10 71 165 2.8 0 3 2.6 04/25/2007 21:40:00 7.6 1.6 12.2 4.6 7.9 1.5 12.6 4.9 7.4 1.4 11.5 3.8 57 10 58 165 2.9 0 3.3 2.3 04/25/2007 21:50:00 8.1 1.5 12.2 4.9 8.4 1.5 12.2 4.9 7.8 1.3 11.5 4.6 62 10 68 165 2.8 0 3 2.3 04/25/2007 22:00:00 8.4 1.5 12.6 4.9 8.6 1.5 13 5.3 8 1.5 12.6 4.6 56 9 61 165 3 0.1 3.3 2.3 04/25/2007 22:10:00 7.9 1.7 11.8 4.6 8.1 1.7 12.2 4.9 7.6 1.5 11.5 4.6 55 10 58 165 3 0.1 3.3 2.6 04/25/2007 22:20:00 8.7 1.4 13 4.6 8.9 1.4 13 4.6 8.3 1.3 13.3 5.3 57 9 52 165 3 0.1 3.3 2.6 04/25/2007 22:30:00 9.5 1.5 13 5.7 9.6 1.6 13.7 6.1 9 1.6 13 5.3 55 11 74 165 3.1 0.1 3.3 2.6 04/25/2007 22:40:00 10 1.7 13.7 5.7 10.2 1.7 14.1 5.7 9.5 1.5 13.7 5.7 57 9 52 165 3.1 0.1 3.5 2.6 04/25/2007 22:50:00 9.1 1.9 16.4 5.3 9.3 2 16.8 5.3 8.6 1.8 14.5 5.3 59 11 74 165 3.1 0.1 3.5 2.6 04/25/2007 23:00:00 11.6 1.8 16.4 8 11.9 1.9 16.8 8 11.1 1.7 16.4 7.2 62 8 57 165 3.1 0 3.5 2.6 04/25/2007 23:10:00 10.7 1.6 14.9 6.8 10.9 1.7 14.9 7.2 10.1 1.4 13.7 7.6 61 9 64 165 3.2 0 3.3 3 04/25/2007 23:20:00 10.1 1.6 15.6 6.1 10.3 1.7 15.6 6.8 9.6 1.7 15.3 6.1 61 9 72 165 3.1 0 3.3 2.8 04/25/2007 23:30:00 10.6 1.7 16.1 6.1 10.8 1.7 15.6 6.1 10.1 1.7 14.1 5.7 59 9 75 165 3.2 0 3.3 2.8 04/25/2007 23:40:00 10.3 1.7 15.6 6.8 10.5 1.8 16.4 6.8 9.7 1.8 14.5 5.7 56 9 46 165 3.1 0 3.3 2.8 04/25/2007 23:50:00 8.3 1.6 13 4.2 8.5 1.6 13 4.6 7.9 1.4 11.5 4.9 49 11 54 165 3 0.1 3.3 2.6 04/26/2007 00:00:00 9.4 1.6 13.7 5.3 9.5 1.6 14.1 5.3 9.1 1.6 13.7 5.3 49 11 46 165 3 0.1 3.3 2.6 04/26/2007 00:10:00 10.6 2.1 16.4 5.3 10.6 2.2 17.2 5.7 9.9 2 16.4 5.7 49 9 56 165 2.9 0 3.3 2.6 04/26/2007 00:20:00 10.7 1.7 14.5 6.1 10.7 1.8 14.9 5.7 10.2 1.9 14.5 4.9 43 9 41 165 3 0 3.3 2.6 04/26/2007 00:30:00 11.8 1.7 17.2 8 11.8 1.7 17.6 8 11.3 1.5 15.3 7.6 38 8 47 165 2.9 0 3 2.6 04/26/2007 00:40:00 12.6 1.5 17.2 8.8 12.6 1.6 17.6 8.4 12.1 1.5 16.4 8 37 8 26 165 2.9 0.1 3.3 2.3 04/26/2007 00:50:00 11.4 1.7 15.6 6.8 11.4 1.7 15.6 7.2 10.9 1.7 15.3 6.5 40 9 32 165 2.9 0.1 3.3 2.6 04/26/2007 01:00:00 11.5 1.7 15.6 6.8 11.5 1.7 16.1 7.2 11 1.6 15.3 6.1 41 8 43 165 2.9 0.1 3 2.6 04/26/2007 01:10:00 11.6 1.8 15.6 6.5 11.6 1.8 15.6 6.5 11 1.9 15.3 6.1 42 8 46 165 2.9 0 3 2.3 04/26/2007 01:20:00 11.4 1.9 16.4 6.8 11.4 1.9 16.4 6.8 10.9 1.9 17.2 6.5 38 9 43 165 2.8 0 3 2.3 04/26/2007 01:30:00 12.3 1.7 16.1 7.2 12.3 1.7 16.1 7.6 12 1.5 16.1 8.4 38 7 44 165 2.8 0 3 2.3 04/26/2007 01:40:00 12.4 1.7 16.4 8 12.4 1.8 16.4 7.6 12 1.7 16.8 8 35 8 37 165 2.9 0 3 2.6 04/26/2007 01:50:00 13 1.5 16.4 8.8 13 1.6 16.8 8.8 12.6 1.5 16.4 9.1 35 7 41 165 2.9 0 3 2.6 04/26/2007 02:00:00 13.2 1.7 16.8 9.1 13.2 1.7 16.8 8.4 12.8 1.7 17.6 8.4 33 7 44 165 2.9 0 3 2.6 04/26/2007 02:10:00 13.4 1.7 17.6 8.8 13.3 1.7 17.2 8.8 13 1.7 17.2 8.4 31 7 26 165 2.9 0 3 2.6 04/26/2007 02:20:00 13.6 1.7 17.9 8.8 13.6 1.7 18.3 8.4 13.2 1.6 18.3 9.1 34 7 23 165 2.9 0 3 2.3 04/26/2007 02:30:00 13.2 1.8 17.2 8.8 13.1 1.9 17.2 8.4 12.5 1.8 17.2 8 32 8 29 165 2.9 0 3 2.6 04/26/2007 02:40:00 14.3 1.8 17.9 8.8 14.3 1.8 18.3 8.4 13.8 1.9 17.9 8.4 32 7 25 165 2.8 0 3 2.6 04/26/2007 02:50:00 12.4 1.7 16.4 7.2 12.3 1.7 16.8 7.2 11.9 1.5 15.6 8 29 9 37 165 2.7 0 3 2.3 04/26/2007 03:00:00 13.7 2.3 19.5 8.4 13.6 2.4 19.5 7.6 13.1 2.2 18.3 8.4 28 8 27 165 2.7 0 2.8 2.3 04/26/2007 03:10:00 14.5 1.9 18.7 9.1 14.4 2.1 19.1 9.1 13.9 2.1 19.5 9.1 29 9 32 165 2.7 0 2.8 1.8 04/26/2007 03:20:00 14.5 1.8 19.1 9.9 14.3 2 18.3 8 13.8 1.7 18.7 9.1 30 8 32 165 2.6 0 2.8 2.1 04/26/2007 03:30:00 14.7 2.3 19.5 8.4 14.5 2.4 19.5 8 14.2 2.4 21 8 28 8 32 165 2.6 0.1 2.8 1.8 04/26/2007 03:40:00 15.5 1.8 21.8 10.7 15.2 1.9 21.4 10.3 14.7 1.9 21 9.1 26 8 357 165 2.6 0 2.8 2.1 04/26/2007 03:50:00 14 2.1 19.1 9.5 13.6 2.3 18.7 8.8 13.3 2 18.3 8.8 25 9 31 165 2.6 0 2.8 2.1 04/26/2007 04:00:00 13.1 1.7 17.6 8.8 12.9 1.8 17.6 8.4 12.6 1.8 16.8 8.8 25 8 32 165 2.6 0 2.8 2.3 04/26/2007 04:10:00 13.1 1.7 17.6 8.8 12.7 1.7 17.6 8 12.5 1.6 16.4 8 22 8 29 165 2.6 0 2.8 2.3 04/26/2007 04:20:00 13.1 1.5 16.8 9.1 12.5 1.6 16.8 8.4 12.6 1.5 17.2 8.8 20 7 19 165 2.6 0 2.8 2.3 04/26/2007 04:30:00 14.1 1.5 17.6 9.5 13.2 1.7 17.2 7.6 13.6 1.5 16.8 9.5 19 7 24 165 2.6 0 2.8 2.3 04/26/2007 04:40:00 14.5 1.8 19.1 9.1 13.3 2.3 19.5 7.6 14 1.9 18.7 9.5 17 8 22 165 2.7 0 2.8 2.3 04/26/2007 04:50:00 14.5 1.9 18.3 9.9 13.6 2.1 18.3 8 13.9 1.9 19.1 9.1 19 8 25 165 2.7 0 2.8 2.3 04/26/2007 05:00:00 15.4 1.9 19.5 9.1 14.3 2.2 19.1 8 14.9 2.1 19.5 9.9 18 7 21 165 2.7 0 2.8 2.6 04/26/2007 05:10:00 14.6 1.6 18.3 9.9 13.7 1.9 18.3 8.4 14 1.6 18.3 9.9 19 8 25 165 2.8 0 2.8 2.6 04/26/2007 05:20:00 14.1 1.8 17.9 10.3 13.3 2.2 18.3 7.6 13.6 1.9 18.3 9.5 18 8 29 165 2.7 0 2.8 2.3 04/26/2007 05:30:00 14.9 1.8 20.2 9.5 14 2.2 19.9 8.4 14.3 1.8 21 9.9 18 8 18 165 2.7 0 2.8 2.3 04/26/2007 05:40:00 14.9 1.9 19.5 11.1 14.3 2.2 19.9 8.8 14.2 2 19.1 9.5 21 7 20 165 2.7 0 2.8 2.3 04/26/2007 05:50:00 14.2 1.8 18.7 9.1 13.6 2 18.7 8.4 13.8 1.7 17.9 9.5 20 7 25 165 2.8 0 3 2.6 04/26/2007 06:00:00 13.8 1.9 17.6 9.1 13.1 2.1 17.9 7.6 13.2 2 17.9 8.4 20 8 15 165 2.8 0 3 2.6 04/26/2007 06:10:00 12.9 2.1 18.7 7.6 12.5 2.3 17.6 6.8 12.4 2 17.9 7.6 23 8 14 165 2.8 0 3 2.6 04/26/2007 06:20:00 13.2 1.7 16.8 8.4 12.7 1.7 16.4 8.4 12.8 1.7 17.6 8.8 22 8 18 165 2.8 0 3 2.6 04/26/2007 06:30:00 12.4 1.7 16.4 7.6 12 1.8 16.8 7.2 12.1 1.7 16.8 8 22 8 18 165 2.8 0 3 2.6 04/26/2007 06:40:00 13.6 1.7 17.2 8 13 2 17.2 7.6 13 1.9 17.6 8.4 21 8 25 165 2.9 0 3 2.6 04/26/2007 06:50:00 13.1 1.5 16.8 8.8 12.7 1.7 16.8 8.4 12.5 1.6 16.1 7.6 22 8 359 165 2.9 0.1 3 2.3 04/26/2007 07:00:00 13.2 1.8 17.9 7.6 12.7 1.9 17.6 7.6 12.4 1.9 16.8 7.6 22 8 17 165 2.9 0.2 3.3 2.3 04/26/2007 07:10:00 13.3 1.7 17.9 9.1 12.9 1.8 17.6 8.4 12.8 1.7 17.6 8.8 21 7 16 165 2.9 0.2 3.3 2.3 04/26/2007 07:20:00 12.9 1.7 16.8 7.2 12.5 1.7 16.8 8.4 12.4 1.6 16.4 8.8 23 8 25 165 2.9 0.2 3.3 2.6 04/26/2007 07:30:00 12 1.5 16.4 7.2 11.7 1.6 16.1 5.7 11.6 1.6 16.8 7.2 23 8 28 165 2.9 0.2 3.3 2.6 04/26/2007 07:40:00 12 1.9 17.6 6.8 11.7 1.9 17.2 6.8 11.7 1.7 17.2 8.4 24 10 20 165 2.9 0.2 3.3 2.3 04/26/2007 07:50:00 11.6 1.8 15.6 6.5 11.3 1.9 16.1 6.5 11 1.8 15.6 6.5 23 9 28 165 2.9 0.2 3.3 2.6 04/26/2007 08:00:00 13.8 2.1 18.7 8.8 13.6 2.2 19.1 9.1 13.3 2.2 19.9 8 26 9 29 165 3 0.2 3.3 2.6 04/26/2007 08:10:00 14 1.8 18.3 9.1 13.6 1.9 18.3 8.8 13.3 1.7 17.6 8.8 23 9 28 165 3 0.2 3.3 2.6 04/26/2007 08:20:00 11.6 1.8 16.8 7.6 11.3 1.9 17.2 7.2 11 1.7 16.1 7.2 25 9 28 165 3 0.1 3.3 2.6 04/26/2007 08:30:00 10.6 1.5 14.1 7.2 10.3 1.5 14.1 6.5 9.9 1.4 13.7 6.5 24 9 29 165 3 0.2 3.3 2.6 04/26/2007 08:40:00 11.5 1.5 15.3 6.8 10.8 1.5 14.5 6.1 10.9 1.5 14.9 7.2 19 8 9 165 3.1 0.2 3.5 2.6 04/26/2007 08:50:00 12.1 1.5 16.1 8 11 1.8 15.3 6.8 11.8 1.3 14.9 8.8 15 7 22 165 3.2 0 3.5 2.6 04/26/2007 09:00:00 12.3 1.7 16.1 8.4 11.7 1.8 16.1 6.5 11.7 1.7 16.1 7.2 19 9 31 165 3.2 0 3.5 3 04/26/2007 09:10:00 12.3 1.6 16.8 8.4 11 2.1 16.1 6.1 12 1.7 16.4 8 15 8 10 165 3.2 0.2 3.5 2.6 04/26/2007 09:20:00 13.7 1.3 17.2 9.1 12.6 1.6 16.8 8.4 13.2 1.5 16.8 9.1 16 7 16 165 3.2 0.2 3.5 2.6 04/26/2007 09:30:00 12 1.5 16.1 8 11.3 1.7 15.6 5.7 11.4 1.5 15.3 7.2 18 8 25 165 3.2 0.3 3.5 2.6 04/26/2007 09:40:00 11.8 1.5 15.6 8.8 11 1.5 14.9 7.2 11.5 1.5 15.3 8 17 7 12 165 3.4 0.2 3.8 2.8 04/26/2007 09:50:00 12.6 1.5 15.6 8.8 11.5 1.8 15.3 6.8 12.3 1.6 16.4 8.8 14 7 20 165 3.4 0.2 3.5 3 04/26/2007 10:00:00 13 1.5 17.2 8.4 11.7 1.7 16.4 7.2 12.2 1.6 17.2 8.4 15 8 11 165 3.4 0.2 3.8 2.8 04/26/2007 10:10:00 12.8 2 18.7 8.8 11.9 2.3 18.7 6.8 12.3 1.9 17.2 8 19 9 27 165 3.3 0.2 3.5 2.8 04/26/2007 10:20:00 12.8 1.5 16.8 8.8 11.3 1.8 16.1 6.5 12.3 1.5 16.8 8.4 14 7 19 165 3.4 0 3.5 3.3 04/26/2007 10:30:00 12.7 1.6 16.8 8.4 11 1.9 16.1 6.1 12.4 1.7 16.4 8.4 12 8 18 165 3.4 0.2 3.8 2.8 04/26/2007 10:40:00 13 1.6 17.2 8.8 11.5 2.1 17.2 6.5 12.6 1.7 17.6 8 13 7 23 165 3.6 0.1 3.8 3 04/26/2007 10:50:00 12.6 1.5 16.1 8.4 11.3 1.8 15.3 7.2 12.2 1.7 16.8 7.6 15 8 22 165 3.8 0 4.3 3.5 04/26/2007 11:00:00 12.3 1.5 16.1 8.8 11.1 1.8 16.1 6.5 11.9 1.4 15.3 8.4 15 8 20 165 4 0.1 4.3 3.5 04/26/2007 11:10:00 11.7 1.5 15.6 8 10.5 1.8 15.3 5.7 11.4 1.4 15.3 8 13 7 21 165 4.1 0 4.3 3.8 04/26/2007 11:20:00 12.5 1.3 15.6 8.8 10.8 1.7 14.5 6.5 12.3 1.4 16.4 8.8 12 7 12 165 4.1 0 4.5 3.8 04/26/2007 11:30:00 13.1 1.4 15.6 9.5 11.9 1.7 15.6 6.8 12.6 1.5 15.6 8.4 14 7 26 165 4.3 0 4.5 4.3 04/26/2007 11:40:00 12.7 1.1 15.6 8.8 11.3 1.6 15.6 7.2 12.5 1.3 16.4 9.5 14 6 26 165 4.6 0.2 5 4.3 04/26/2007 11:50:00 12.4 1.7 16.4 7.6 11.1 2 16.1 5.7 12.2 1.7 17.2 8 14 7 23 165 4.7 0.1 5 4.3 04/26/2007 12:00:00 12.8 1.5 15.6 8.8 12.1 1.7 15.6 6.8 12.2 1.5 16.1 8 17 8 10 165 4.4 0 4.8 4.3 04/26/2007 12:10:00 12.7 1.6 16.4 8.4 11.4 2 16.1 5.7 12.2 1.7 15.6 8 13 8 14 165 4.4 0 4.8 4.3 04/26/2007 12:20:00 11.9 1.5 15.3 7.6 11.2 1.7 14.9 6.8 11.4 1.6 15.6 7.6 17 8 19 165 4.4 0 4.8 4.3 04/26/2007 12:30:00 10.6 1.4 13.3 6.8 9.9 1.7 13.7 4.9 10.3 1.5 13.3 6.5 16 7 25 165 4.6 0 4.8 4.3 04/26/2007 12:40:00 10.2 1.2 13 6.8 8.7 1.5 11.8 4.6 9.8 1.3 13.7 5.7 11 7 358 165 4.8 0 5 4.3 04/26/2007 12:50:00 10 1.2 13 6.1 8.6 1.3 11.5 4.9 9.8 1.3 13 7.2 12 7 8 165 5.2 0 5.7 4.8 04/26/2007 13:00:00 10 1.3 13.7 5.3 9.3 1.5 13 4.9 9.7 1.3 13 6.1 17 8 7 165 5.4 0.1 5.7 5.2 04/26/2007 13:10:00 9.9 1.2 13 6.1 8.9 1.6 12.6 4.6 9.7 1.2 12.6 6.5 13 7 23 165 5.3 0 5.7 5 04/26/2007 13:20:00 8.3 1.1 11.1 4.6 6.9 1.4 10.3 3.4 8.1 1 10.7 5.7 11 9 356 165 5.7 0.1 6.2 5.5 04/26/2007 13:30:00 8.5 1.6 14.1 4.2 7.2 1.6 13 3.4 8.2 1.6 13.7 4.6 10 12 6 165 6.7 0.3 7.3 6 04/26/2007 13:40:00 9.1 2.2 13.7 4.2 8.1 2.6 14.9 3 8.8 1.9 14.1 4.2 354 13 358 165 6.7 0.3 7.3 6.2 04/26/2007 13:50:00 10.2 1.8 15.3 6.1 8.3 2.4 15.3 3.8 10.1 1.8 14.9 5.3 355 7 351 165 6.2 0 6.5 6 04/26/2007 14:00:00 12 1.9 16.8 6.8 9.9 2.4 16.4 4.6 11.6 2.1 17.2 6.8 357 8 355 165 6.1 0 6.2 5.7 04/26/2007 14:10:00 12.4 1.4 16.1 8.4 10 2.2 16.1 4.9 12.2 1.5 16.8 8.8 356 7 2 165 6.3 0 6.7 6.2 04/26/2007 14:20:00 8.9 1.5 12.2 4.9 7 1.7 11.5 3.4 8.7 1.5 12.6 5.3 3 9 357 165 6.7 0.1 7 6.5 04/26/2007 14:30:00 8.6 1.5 12.6 4.6 7.6 1.4 11.5 4.2 8.4 1.3 12.2 4.9 15 10 6 165 6.9 0.1 7.3 6.5 04/26/2007 14:40:00 9.2 1.2 12.6 6.1 8.8 1.4 12.2 4.6 8.8 1.2 11.5 5.7 21 9 21 165 6.4 0.1 6.7 6 04/26/2007 14:50:00 8 1.3 10.7 3.8 8 1.3 10.7 4.2 7.6 1.3 11.1 4.9 27 9 23 165 5.8 0.1 6.2 5.7 04/26/2007 15:00:00 8.3 1.2 11.1 5.3 8.4 1.2 11.1 4.6 8.2 1.2 11.1 5.3 33 6 30 165 5.4 0.1 5.7 5.2 04/26/2007 15:10:00 5.8 1.4 9.1 2.3 6 1.4 9.1 1.9 5.7 1.5 9.1 1.9 36 12 53 165 5.3 0 5.5 5 04/26/2007 15:20:00 4.2 0.6 5.7 2.6 3.5 0.8 6.1 1.5 4.4 0.6 5.7 3 9 8 29 165 5.8 0.1 6 5.2 04/26/2007 15:30:00 5 0.7 6.5 3 3.5 0.8 5.7 1.5 5.3 0.6 7.2 3.8 6 5 12 165 6.4 0.1 6.7 6 04/26/2007 15:40:00 5.7 0.5 6.8 4.6 4.1 1 6.5 2.3 5.9 0.6 7.6 4.6 8 7 15 165 6.9 0.1 7.3 6.5 04/26/2007 15:50:00 5.9 0.6 7.6 4.2 4.6 1.1 6.8 2.3 6.1 0.7 8 4.2 8 7 14 165 7.5 0.1 7.8 7.3 04/26/2007 16:00:00 6.5 0.9 9.1 4.6 5.1 1.3 8 2.3 6.8 0.8 9.5 4.9 6 9 2 165 8 0 8.3 7.5 04/26/2007 16:10:00 6.6 1 9.1 4.2 5.4 1.4 8.8 2.6 6.8 1 9.5 4.6 357 11 4 165 8.4 0.2 8.8 8 04/26/2007 16:20:00 7.7 1.2 11.5 4.6 6.7 1.6 11.1 3.4 7.6 1.2 11.1 4.6 355 12 18 165 8.2 0 8.8 8 04/26/2007 16:30:00 8.2 1.5 13 4.2 6.7 1.8 12.6 3.4 8.1 1.5 12.2 4.6 357 11 353 165 8.5 0.1 9 8.5 04/26/2007 16:40:00 8.3 1 11.5 5.3 6.7 1.5 10.3 3.4 8.3 1.2 11.8 5.3 357 9 3 165 8.4 0.1 8.8 8.3 04/26/2007 16:50:00 9 1 11.5 6.5 7 1.4 10.3 3.8 9.1 1.1 12.2 6.1 360 8 5 165 8.4 0.2 8.8 8 04/26/2007 17:00:00 7.3 1.7 13.3 4.2 6.8 1.4 12.6 3.4 7.4 1.6 14.1 4.2 353 13 14 165 8 0 8.5 7.8 04/26/2007 17:10:00 8.2 1.6 12.2 4.6 8.1 1.6 12.2 3.8 8.1 1.6 11.5 4.9 330 12 327 165 8.3 0.2 8.5 8 04/26/2007 17:20:00 9.2 1 11.5 6.5 9.2 1 11.8 6.5 8.8 1 11.8 6.5 327 12 337 165 8.3 0 8.5 8 04/26/2007 17:30:00 9.3 1.2 13.7 6.5 9.3 1.2 13.3 6.1 8.4 1.4 12.6 4.6 317 15 322 165 7.9 0 8.3 7.5 04/26/2007 17:40:00 8.6 1.1 11.1 5.7 8.6 1.1 11.8 5.7 8.3 1.1 10.7 4.6 326 14 334 165 7.9 0 8.3 7.8 04/26/2007 17:50:00 8.6 1.2 11.8 5.3 8.6 1.1 11.5 5.7 8.5 1.2 11.8 5.3 331 12 336 165 8 0 8.3 7.8 04/26/2007 18:00:00 8.7 1.3 12.2 4.2 8.7 1.2 12.2 4.9 8.1 1.2 11.8 4.2 316 11 310 165 7.8 0.1 8 7.5 04/26/2007 18:10:00 8.5 1 11.5 5.3 8.5 1 11.5 5.7 8.4 1 11.8 5.7 331 10 342 165 7.8 0 8 7.5 04/26/2007 18:20:00 8.4 1.3 13 4.9 8.3 1.3 13.3 4.9 7.8 1.4 11.8 4.9 323 11 341 165 7.7 0.1 8 7.5 04/26/2007 18:30:00 11.1 2.2 16.1 5.3 10.8 2.4 16.1 5.3 11 2 16.4 5.3 331 13 334 165 7.4 0.1 8 7.3 04/26/2007 18:40:00 12.4 1.7 17.9 8.4 12.2 1.7 17.6 8 12 1.7 16.8 7.6 328 13 315 165 7 0.1 7.3 6.5 04/26/2007 18:50:00 15 1.9 20.2 9.5 14.8 1.9 19.9 9.1 14.6 2 19.5 8.8 331 10 328 165 7 0 7.3 6.7 04/26/2007 19:00:00 14.7 1.8 20.6 11.5 14.4 1.9 20.6 10.7 14.4 1.9 18.7 9.9 332 11 321 165 7 0 7.3 6.2 04/26/2007 19:10:00 14.2 1.8 18.7 9.9 14 1.9 18.7 9.9 13.7 2.1 19.1 9.1 325 11 319 165 6.9 0 7.3 6.7 04/26/2007 19:20:00 13.4 1.9 18.7 9.5 13.2 1.8 17.9 9.5 13.1 1.9 17.9 8.4 326 9 322 165 7.1 0 7.3 7 04/26/2007 19:30:00 12.2 1.9 19.9 7.6 11.9 1.8 19.5 7.6 11.7 2 17.9 7.2 329 13 329 165 7.1 0 7.3 7 04/26/2007 19:40:00 13 1.7 19.1 9.1 12.7 1.7 18.7 8 12.6 1.8 19.5 8.4 329 11 325 165 7 0.1 7.5 6.2 04/26/2007 19:50:00 11.5 1.7 15.6 7.2 11.3 1.7 16.1 7.2 11.2 1.8 16.8 7.2 330 11 338 165 6.9 0.1 7.3 6.2 04/26/2007 20:00:00 12.4 1.7 19.1 8.8 11.8 1.6 17.2 6.8 12.2 1.7 18.3 8 338 16 354 165 7.1 0 7.3 6.7 04/26/2007 20:10:00 14.5 2.6 21.8 6.5 12.7 2.4 19.9 7.6 14.5 2.8 22.1 4.2 350 11 358 165 7.1 0 7.5 6.5 04/26/2007 20:20:00 15.3 1.9 20.2 8.8 14.3 2.5 20.6 6.8 15.1 2 19.9 9.5 346 9 341 165 6.9 0.2 7.3 6.2 04/26/2007 20:30:00 15.7 1.6 21 11.5 13.3 2.4 19.9 8 15.5 1.7 20.6 11.5 353 10 4 165 6.6 0 7 6.5 04/26/2007 20:40:00 13.5 1.1 16.4 10.7 11.2 2.5 16.4 6.1 13.2 1.1 16.4 10.3 354 7 6 165 6.4 0 6.7 6.2 04/26/2007 20:50:00 11.8 1.5 15.3 7.2 8.6 1.7 13.7 4.6 11.6 1.5 16.1 7.6 360 7 353 165 6.2 0 6.7 6 04/26/2007 21:00:00 10.8 1.6 14.5 7.2 9.6 1.7 14.1 5.3 10.6 1.7 15.6 7.2 16 8 19 165 5.8 0.2 6.2 5.2 04/26/2007 21:10:00 10.8 1.3 13.7 7.6 8.8 2 13.3 4.6 10.6 1.3 14.1 6.8 11 8 16 165 4.9 0.1 5.5 4.3 04/26/2007 21:20:00 10.4 1.2 13 6.8 8.9 1.7 12.6 5.3 10.2 1.2 13.7 7.6 13 7 14 165 4.7 0.1 5 4.3 04/26/2007 21:30:00 10.7 0.9 13 8 10.5 1 13 8 10.4 1 12.6 7.2 23 6 28 165 4.6 0 4.8 4.3 04/26/2007 21:40:00 10.9 1 13.3 7.6 10.2 1.5 13.3 5.3 10.7 1.2 13.7 6.8 18 7 23 165 4.3 0.1 4.5 4 04/26/2007 21:50:00 10.5 1 14.1 7.6 8.2 1.5 11.8 4.6 10.2 1.2 13.3 6.8 9 8 14 165 4.1 0 4.3 3.8 04/26/2007 22:00:00 9 1.3 13.7 6.8 7.1 1.7 13.3 3.8 9 1.2 13.7 6.5 8 9 31 165 4.1 0.1 4.5 3.5 04/26/2007 22:10:00 9.4 0.9 12.2 6.8 6.8 1.2 9.9 4.2 9.5 0.9 11.8 6.8 6 7 4 165 4 0.1 4.3 3.5 04/26/2007 22:20:00 9.9 1.5 13.3 6.1 7.3 1.5 12.2 3.4 9.8 1.5 13.7 5.7 2 9 3 165 4.1 0.1 4.5 3.5 04/26/2007 22:30:00 9.5 1.7 13.3 4.9 7 1.5 11.8 3.8 9.3 1.5 13.3 6.5 5 8 11 165 4.2 0 4.5 3.8 04/26/2007 22:40:00 8.9 1 11.5 5.3 6.2 1.3 10.3 3.8 9.1 1 13.3 6.1 2 7 6 165 4.1 0.1 4.5 3.8 04/26/2007 22:50:00 9.4 1.3 12.6 6.5 7.1 1.5 11.5 3.8 9.5 1.4 12.6 6.8 5 8 14 165 4.3 0 4.5 4.3 04/26/2007 23:00:00 10.2 1.3 13.3 7.2 7.6 1.6 11.5 4.2 10.2 1.3 13.3 7.2 2 8 5 165 4.3 0 4.5 3.8 04/26/2007 23:10:00 11.1 1.4 14.9 7.6 8.6 2.1 15.6 4.6 10.8 1.4 14.5 8 359 9 345 165 4.4 0 4.8 4.3 04/26/2007 23:20:00 11 1.6 15.3 6.8 8.8 2.2 15.6 4.2 10.7 1.7 16.8 6.1 3 10 349 165 4.4 0 4.5 3.8 04/26/2007 23:30:00 9.6 1.2 13.3 6.8 7.3 1.7 12.6 4.2 9.6 1.2 13 6.8 6 9 28 165 4.4 0 4.8 4.3 04/26/2007 23:40:00 10.3 1.8 15.3 6.8 7.8 2 14.1 4.2 10.2 1.7 15.6 6.8 7 8 11 165 4.3 0 4.5 4.3 04/26/2007 23:50:00 10.8 1.5 15.3 7.2 8.2 1.9 14.5 4.2 10.8 1.7 15.3 7.2 5 8 19 165 4.4 0 4.8 4.3 04/27/2007 00:00:00 10.1 1.2 13.3 6.5 7.8 1.7 11.5 4.6 10.1 1.2 13.3 6.8 6 10 359 165 4.3 0 4.5 4.3 04/27/2007 00:10:00 10.2 1.2 13 6.8 8.3 1.5 11.5 4.6 9.9 1.2 12.6 6.8 7 9 12 165 4.3 0 4.5 4.3 04/27/2007 00:20:00 11 1.3 13.7 8 8.4 1.6 12.2 4.9 10.9 1.4 14.1 7.6 9 8 5 165 4.3 0 4.5 4 04/27/2007 00:30:00 11.2 1.4 14.5 6.8 9.3 1.9 13.7 4.9 11.1 1.5 14.9 6.8 12 8 14 165 4.2 0.1 4.5 4 04/27/2007 00:40:00 10.9 1.4 15.3 6.8 8 1.5 13 4.6 11 1.5 14.1 6.5 5 7 359 165 4.1 0 4.5 4 04/27/2007 00:50:00 11.1 1.3 14.9 8 8.5 1.8 14.5 4.9 11.1 1.3 14.1 8 6 9 14 165 4.2 0 4.5 4.3 04/27/2007 01:00:00 10.1 1.2 14.1 6.5 8.4 1.5 11.8 4.9 9.8 1.3 13.7 7.2 10 7 14 165 4.1 0.1 4.5 4 04/27/2007 01:10:00 10.3 1.1 14.5 6.8 7.9 1.7 13.3 4.6 10.2 1.1 13.3 7.6 9 6 17 165 4.1 0 4.5 3.8 04/27/2007 01:20:00 10.9 1.5 13.7 7.2 8.4 1.7 12.6 4.9 10.8 1.5 13.7 7.6 9 7 8 165 4.1 0 4.5 4 04/27/2007 01:30:00 10.7 1.4 13.3 6.5 8.4 1.7 12.6 3.8 10.6 1.5 13.7 6.8 10 8 11 165 4.1 0 4.3 3.8 04/27/2007 01:40:00 10.5 1.3 14.5 6.8 8.6 1.5 13 4.9 10.4 1.3 14.1 6.8 11 6 10 165 4.1 0.1 4.5 3.5 04/27/2007 01:50:00 10.4 1.1 13.7 8 8.4 1.6 11.8 4.9 10 1.2 13.7 7.2 10 7 18 165 3.9 0 4.3 3.5 04/27/2007 02:00:00 9.8 1.3 13 5.3 7.6 1.7 13 4.2 9.7 1.3 14.1 5.3 7 9 22 165 3.8 0 4 3.3 04/27/2007 02:10:00 10.9 1.5 14.5 6.5 8.6 1.7 13.7 4.9 10.6 1.5 14.5 6.8 8 7 2 165 3.8 0 4 3.3 04/27/2007 02:20:00 10.5 1.4 13.7 6.8 8.4 1.7 13 4.6 10.3 1.3 13.7 7.2 10 8 14 165 3.7 0 4 3.3 04/27/2007 02:30:00 10.5 1.4 14.5 7.2 7.6 1.4 11.5 4.6 10.4 1.5 14.5 6.8 5 7 359 165 3.7 0 4 3.3 04/27/2007 02:40:00 10.6 1.2 14.1 7.6 7.9 1.7 11.8 4.6 10.6 1.3 14.1 7.2 3 8 1 165 3.8 0 4 3.3 04/27/2007 02:50:00 10.8 1.4 14.9 7.2 8.4 1.7 13 4.2 10.7 1.5 14.9 6.8 359 9 10 165 3.8 0 4.3 3.3 04/27/2007 03:00:00 10.5 1.5 15.6 7.6 8.4 2 14.1 4.6 10.3 1.6 16.4 7.2 360 9 354 165 3.8 0 4.3 3.3 04/27/2007 03:10:00 12.3 1.6 17.9 8.4 10.3 2.2 15.6 6.1 12.1 1.7 19.1 8 355 9 1 165 4 0.1 4.3 3.3 04/27/2007 03:20:00 13 1.6 18.7 8.8 11.5 2.4 19.1 6.1 12.5 1.7 18.3 7.6 351 8 343 165 4 0.1 4.3 3.3 04/27/2007 03:30:00 12.7 1.8 17.9 8.4 10.6 2.9 19.1 5.7 12.2 1.7 17.2 6.8 355 8 349 165 3.9 0.1 4.3 3.3 04/27/2007 03:40:00 12.7 2.1 18.7 7.2 10.4 2.6 19.1 4.9 12.3 1.8 17.9 8 356 9 352 165 3.9 0 4.3 3.3 04/27/2007 03:50:00 11.1 1.6 14.9 6.8 8.5 2 13.3 3.8 11 1.6 14.5 7.2 358 8 9 165 3.9 0 4.3 3.8 04/27/2007 04:00:00 10.9 1.6 16.1 7.6 9 1.9 15.3 4.9 10.7 1.6 15.3 7.6 359 11 7 165 3.8 0 4.3 3.5 04/27/2007 04:10:00 11.5 1.7 18.3 7.6 9.3 2.2 17.6 5.3 11.2 1.7 17.9 7.6 2 11 20 165 4 0 4.3 3.5 04/27/2007 04:20:00 10.5 1.4 15.3 7.6 8.4 1.7 13.7 4.9 10.3 1.3 14.9 7.2 0 9 10 165 3.9 0 4.3 3.8 04/27/2007 04:30:00 10.6 1.4 14.1 7.2 8.2 1.7 13.7 4.9 10.3 1.3 14.1 7.6 4 9 14 165 3.9 0 4.3 3.5 04/27/2007 04:40:00 12.3 1.4 16.4 9.1 9 1.8 14.9 4.6 12.3 1.5 16.1 8.8 6 7 10 165 3.8 0 4.3 3.5 04/27/2007 04:50:00 12.3 1.6 17.2 7.6 9.4 2 16.1 5.7 12.2 1.7 16.4 7.6 7 9 14 165 4 0 4.3 3.5 04/27/2007 05:00:00 11.6 1.6 16.4 8.4 8.7 1.9 14.9 5.3 11.3 1.7 16.4 7.6 5 9 6 165 3.9 0 4.3 3.5 04/27/2007 05:10:00 12.2 2 16.8 6.5 9.6 2.4 16.1 4.2 12 2.1 17.2 6.8 6 10 16 165 4 0 4.3 3.8 04/27/2007 05:20:00 11.4 1.9 17.6 7.6 8.3 1.7 15.3 4.6 11.3 1.9 17.9 6.8 2 8 10 165 4 0 4.3 3.8 04/27/2007 05:30:00 12.5 2.2 19.1 7.2 9.6 1.9 16.8 5.7 12.2 2.1 17.9 7.2 2 10 5 165 4 0 4.3 3.5 04/27/2007 05:40:00 12.4 1.9 18.3 7.6 9.4 2.2 16.8 5.3 12.2 2.1 16.8 7.6 4 9 11 165 4 0 4.3 3.8 04/27/2007 05:50:00 13.4 1.7 17.2 8.8 10.9 1.9 17.2 6.1 13.2 1.7 17.2 7.6 8 9 360 165 4 0 4.3 3.8 04/27/2007 06:00:00 13.5 1.5 18.3 9.9 11.5 2.2 16.8 5.7 13.1 1.6 17.6 9.1 12 8 17 165 3.9 0 4.3 3.5 04/27/2007 06:10:00 12.9 1.5 17.2 9.1 10.6 1.9 16.4 6.1 12.5 1.5 16.4 9.1 11 7 27 165 3.8 0 4.3 3.5 04/27/2007 06:20:00 13.7 1.5 17.9 9.1 11.8 1.9 17.2 6.8 13.4 1.7 17.9 8.8 12 8 8 165 3.9 0 4.3 3.5 04/27/2007 06:30:00 13.9 1.6 17.6 9.9 11.2 2 16.4 7.2 13.6 1.7 18.3 9.5 10 7 21 165 4 0 4.3 3.5 04/27/2007 06:40:00 14.8 1.7 18.7 9.9 12.4 2.2 17.6 7.2 14.4 1.8 18.7 9.9 12 7 15 165 4 0.1 4.3 3.5 04/27/2007 06:50:00 16.3 1.9 22.9 10.3 14.1 2.6 22.6 8 15.9 2.2 21.4 9.5 14 8 23 165 4 0 4.3 3.5 04/27/2007 07:00:00 15.2 1.8 19.1 9.9 12.3 2.4 17.9 6.5 14.6 2 19.1 8.8 9 8 23 165 4.1 0.1 4.5 3.5 04/27/2007 07:10:00 14.4 2.1 19.9 10.3 11.3 2.2 16.8 6.8 14 2.2 19.9 9.1 9 8 12 165 4.1 0.1 4.5 3.5 04/27/2007 07:20:00 12.5 1.6 16.4 7.2 10.6 1.8 16.4 6.1 12.1 1.6 16.1 8 11 8 8 165 4.1 0.2 4.5 3.5 04/27/2007 07:30:00 13.3 1.9 18.7 8.4 10.9 2.4 16.8 6.1 12.9 1.9 17.9 8.8 10 8 9 165 4 0.2 4.3 3.5 04/27/2007 07:40:00 13.3 1.7 17.6 9.5 11.5 2.2 16.4 6.5 12.6 1.7 17.2 9.1 13 8 18 165 4.1 0.1 4.3 3.5 04/27/2007 07:50:00 15.9 1.6 19.9 11.1 14.2 2.2 19.9 8 15.1 1.7 19.1 9.9 15 7 26 165 4.1 0.1 4.5 3.5 04/27/2007 08:00:00 13.5 1.8 18.3 8.8 11.9 2 16.8 6.8 13.1 1.7 17.2 8 14 8 3 165 4.1 0.1 4.5 3.5 04/27/2007 08:10:00 13.6 1.5 16.8 9.1 12.4 1.8 16.4 7.2 13 1.7 16.8 8.8 17 7 19 165 4.1 0.1 4.5 3.5 04/27/2007 08:20:00 14 1.7 18.3 9.1 12.7 2.2 17.9 7.2 13.4 1.7 16.8 9.1 16 8 22 165 4 0 4.3 3.5 04/27/2007 08:30:00 12.8 1.5 16.8 8 11.4 1.9 15.3 6.5 12.5 1.7 16.4 8.4 14 8 2 165 4 0 4.3 3.8 04/27/2007 08:40:00 13.6 1.5 17.9 9.9 11.8 1.9 16.4 7.2 13.2 1.5 17.9 9.1 14 6 18 165 4 0 4.3 3.8 04/27/2007 08:50:00 12.8 1.3 16.1 8.8 10.3 1.6 14.5 6.1 12.6 1.4 15.6 8.8 10 7 7 165 4 0 4.3 3.8 04/27/2007 09:00:00 12.2 1.5 15.6 7.6 10.1 1.8 14.5 6.5 11.9 1.8 16.1 7.6 11 7 10 165 4 0 4.3 3.8 04/27/2007 09:10:00 12 1.5 15.6 8 9.7 1.7 14.1 5.7 11.7 1.4 14.9 8 10 7 5 165 4 0 4.3 3.8 04/27/2007 09:20:00 12.4 1.5 16.1 9.5 11.1 1.8 15.6 6.5 12 1.5 15.6 8 15 7 17 165 4 0 4.3 3.8 04/27/2007 09:30:00 13.6 1.3 16.4 10.3 12 1.8 16.1 7.6 13 1.5 16.4 8.8 15 6 7 165 4 0 4.3 3.8 04/27/2007 09:40:00 12.5 1.3 15.3 8.8 10.9 1.7 14.5 5.7 12.1 1.5 15.6 8.4 14 6 356 165 4.1 0 4.3 3.8 04/27/2007 09:50:00 11.2 1.3 14.1 7.6 9.5 1.7 13.3 5.7 10.7 1.2 14.1 8 11 8 15 165 4.3 0 4.5 4 04/27/2007 10:00:00 12 1.3 16.1 9.1 9.9 1.7 14.9 5.3 11.7 1.5 15.6 8.4 12 6 5 165 4.4 0 4.8 4.3 04/27/2007 10:10:00 11.3 1.3 14.5 8 9.3 1.7 14.1 5.7 10.9 1.4 14.5 7.2 11 8 18 165 4.8 0 5 4.3 04/27/2007 10:20:00 11.4 1.5 14.5 7.2 10 1.8 14.1 4.9 11.1 1.7 15.3 6.5 14 8 19 165 4.6 0 5 4.3 04/27/2007 10:30:00 11.7 1.3 14.9 8.4 10.9 1.5 14.5 6.8 11.1 1.4 14.5 7.2 18 6 28 165 4.3 0.1 4.8 4.3 04/27/2007 10:40:00 12.4 1.3 14.9 7.2 11.3 1.8 14.9 5.3 11.9 1.5 14.9 8 17 7 29 165 4.1 0.1 4.5 3.5 04/27/2007 10:50:00 12 1.2 14.5 8.4 10.7 1.5 14.1 6.8 11.5 1.4 14.5 7.6 15 7 23 165 4 0.2 4.3 3.5 04/27/2007 11:00:00 10.8 1.3 14.1 7.2 9.4 1.6 13.7 5.3 10.5 1.4 13.7 7.6 14 7 19 165 4 0.2 4.5 3.3 04/27/2007 11:10:00 9.1 1 11.5 6.8 7.4 1.4 10.7 4.2 9 1 11.1 6.1 10 8 5 165 4.2 0.1 4.5 3.5 04/27/2007 11:20:00 9.2 1 12.6 6.5 7.5 1.7 12.2 4.6 8.8 1 11.8 6.1 11 11 29 165 4.3 0 4.5 4.3 04/27/2007 11:30:00 10.7 1.3 13.3 6.8 10 1.8 13 4.6 10.2 1.3 13.3 6.8 19 9 12 165 3.5 0.3 4.3 2.8 04/27/2007 11:40:00 10.2 1.2 13.3 6.8 8.9 1.4 12.6 5.3 10 1.2 12.6 6.8 15 7 10 165 3.5 0.2 4 3 04/27/2007 11:50:00 10.1 1.2 14.1 6.8 8.2 1.5 13 4.9 10 1.1 13.3 7.2 11 6 12 165 3.8 0.2 4.3 3.3 04/27/2007 12:00:00 9.6 1 11.8 6.1 8.2 1.4 11.8 4.2 9.7 1 12.6 6.1 13 8 18 165 4.3 0 4.5 3.8 04/27/2007 12:10:00 10.7 1.3 13.3 6.1 9.9 1.5 13.3 4.6 10.2 1.3 13.3 6.5 16 7 22 165 4.1 0.1 4.5 3.8 04/27/2007 12:20:00 9.5 1.2 12.6 6.1 7.1 1.5 11.1 3.4 9.4 1.2 12.6 6.1 6 8 11 165 4.4 0.1 4.8 3.8 04/27/2007 12:30:00 9.3 1.7 14.1 5.3 8.8 2 13 4.2 9.1 1.7 13.3 5.3 19 9 18 165 4.4 0.2 4.8 3.8 04/27/2007 12:40:00 11.1 1.2 13 7.2 10.5 1.5 13 4.9 10.5 1.3 13 6.8 19 6 23 165 3.9 0 4.3 3.5 04/27/2007 12:50:00 9.9 1.2 12.6 6.5 8.2 1.6 11.5 4.6 9.6 1.1 12.6 6.1 10 7 4 165 3.9 0.2 4.5 3.5 04/27/2007 13:00:00 9.3 1.2 12.2 5.7 8.4 1.5 11.8 4.6 9.2 1.2 11.5 5.7 14 8 15 165 4.3 0 4.8 4.3 04/27/2007 13:10:00 10 1.3 13 6.8 9.5 1.5 13 4.2 9.6 1.4 12.6 5.7 18 6 22 165 4.1 0 4.5 4 04/27/2007 13:20:00 9.2 1 11.5 6.1 8.7 1.2 11.1 4.9 9.2 1 11.8 6.8 18 6 15 165 4.4 0.1 4.8 4.3 04/27/2007 13:30:00 8.7 1 11.1 5.7 8 1.1 10.7 4.9 8.5 1 10.7 5.3 16 7 26 165 4.6 0 4.8 4.3 04/27/2007 13:40:00 8.4 1.1 10.7 5.3 7.5 1.3 10.7 3.8 8.4 1.1 11.1 5.7 15 8 18 165 4.6 0 4.8 4.5 04/27/2007 13:50:00 9.8 1 12.2 7.2 9 1.5 12.2 4.9 9.6 1 12.2 6.8 16 7 3 165 4.4 0 4.8 4.3 04/27/2007 14:00:00 9.6 1 11.8 6.8 8.9 1.3 11.5 4.6 9.3 1.2 12.2 6.8 18 7 20 165 4.4 0 4.8 4.3 04/27/2007 14:10:00 9.1 1 12.2 6.1 8.6 1.1 12.2 5.7 8.8 1.1 11.1 5.7 20 7 28 165 4.6 0 4.8 4.5 04/27/2007 14:20:00 9 1.1 11.8 6.5 8.7 1.3 11.8 4.9 8.7 1.2 12.2 5.7 23 9 32 165 4.4 0.2 4.8 4 04/27/2007 14:30:00 9.2 1.4 13.3 4.9 9.1 1.4 13.3 4.9 8.8 1.4 13.3 5.3 28 8 25 165 4 0 4.3 3.8 04/27/2007 14:40:00 9.6 1.5 13.7 6.5 9.4 1.6 13.7 5.7 9.3 1.5 13.7 5.7 25 9 33 165 3.5 0.3 4 2.8 04/27/2007 14:50:00 9 0.8 11.1 6.5 8.6 1 10.7 5.3 8.8 1 11.5 5.7 19 6 18 165 3.7 0.2 4.3 3 04/27/2007 15:00:00 8.6 1 11.1 6.1 8 1.1 10.7 5.3 8.3 1.1 10.7 5.3 18 7 23 165 4.1 0.1 4.5 3.5 04/27/2007 15:10:00 8.8 0.9 10.7 6.1 8.6 1 10.3 6.1 8.5 0.9 10.7 6.1 21 6 23 165 4.1 0.1 4.5 3.5 04/27/2007 15:20:00 9 0.9 10.7 6.5 8.6 1 10.7 4.9 8.8 0.9 11.1 6.5 19 6 22 165 4.1 0.1 4.5 3.5 04/27/2007 15:30:00 8.6 1 10.3 5.7 8.1 1 10.3 4.6 8.3 1 10.7 5.7 18 6 19 165 4.6 0.1 4.8 4 04/27/2007 15:40:00 8.3 1.1 9.9 4.9 8 1.2 9.9 3.8 8.2 1 10.3 5.3 20 6 21 165 4.6 0.1 5 4.3 04/27/2007 15:50:00 8.4 1.2 11.1 5.7 7.9 1.3 11.1 4.9 8.2 1.2 11.1 5.3 18 6 15 165 4.1 0.1 4.5 3.5 04/27/2007 16:00:00 7.8 1 9.9 5.3 7.1 1.1 9.5 3.8 7.8 1 10.7 5.7 14 7 14 165 4.1 0.1 4.5 3.8 04/27/2007 16:10:00 7 0.9 9.1 4.6 6.3 1.1 8.8 3.4 7.1 0.9 9.5 4.9 16 9 7 165 4.3 0 4.5 3.8 04/27/2007 16:20:00 8.5 1.1 10.3 5.3 8.1 1.2 9.9 3.4 8.4 1.2 10.3 4.9 19 7 11 165 4 0.1 4.5 3.5 04/27/2007 16:30:00 8.1 0.8 9.9 5.7 7.3 1 9.5 4.9 7.9 0.8 9.5 5.7 15 6 18 165 3.8 0.1 4.3 3.5 04/27/2007 16:40:00 7.2 1.2 10.3 4.6 6.1 1.2 8.4 3.4 7.2 1.1 10.3 4.9 14 8 16 165 3.8 0.1 4.3 3.5 04/27/2007 16:50:00 7.8 0.9 9.9 5.3 6.1 1.1 8.8 3.4 8 0.8 9.9 6.1 9 7 10 165 4 0.2 4.3 3.5 04/27/2007 17:00:00 7.5 1 9.9 5.3 6 1.2 8.8 3.4 7.6 0.9 10.3 5.7 10 7 7 165 4.2 0 4.5 3.8 04/27/2007 17:10:00 7.3 1 9.9 4.9 6.9 1.3 9.9 3.4 7.4 1 10.3 5.3 18 7 20 165 4.1 0.1 4.5 3.8 04/27/2007 17:20:00 8.1 1 10.3 5.3 7.2 1.2 9.9 3.4 8 1 10.3 5.3 15 7 23 165 4.1 0.1 4.5 3.5 04/27/2007 17:30:00 7.7 0.8 9.5 5.3 6.5 1 8.8 3.4 7.7 0.8 9.5 5.7 12 6 12 165 4.2 0 4.5 4 04/27/2007 17:40:00 8 0.8 9.9 5.7 7.6 1 9.9 4.2 7.9 0.8 9.9 5.7 18 5 20 165 4.1 0.1 4.5 3.5 04/27/2007 17:50:00 7.2 0.7 9.1 4.9 6.8 1 8.8 2.6 7.1 0.7 8.8 5.3 17 6 20 165 4 0.1 4.3 3.5 04/27/2007 18:00:00 6.2 0.8 8 4.6 5.6 1 7.6 2.6 6.1 0.9 8.8 3.8 14 7 14 165 4 0.1 4.3 3.8 04/27/2007 18:10:00 5.3 0.9 7.6 3.8 5.2 1 7.2 2.6 5.5 1 7.6 3.4 17 7 18 165 4 0 4.3 3.5 04/27/2007 18:20:00 5.1 0.7 6.5 3.4 4.9 0.7 6.5 3 5.3 0.7 7.2 3.4 17 7 13 165 4 0.1 4.3 3.5 04/27/2007 18:30:00 6.1 0.7 7.6 4.2 5.8 0.8 7.6 3 6 0.8 8 3.8 18 7 18 165 4 0.1 4.3 3.5 04/27/2007 18:40:00 5.6 0.8 7.6 3.4 5.6 0.9 7.6 3.4 5.8 0.7 7.6 4.2 19 6 21 165 3.8 0.1 4.3 3.3 04/27/2007 18:50:00 5.1 0.7 6.8 3 5 0.8 6.8 3 5.4 0.7 6.8 3.4 19 7 7 165 3.6 0.2 4 3 04/27/2007 19:00:00 5.5 0.8 7.6 3.8 5.3 0.9 7.2 3 5.7 0.8 7.6 3.8 17 7 15 165 3.6 0 4 3.3 04/27/2007 19:10:00 5 0.7 6.5 3 4.5 0.8 6.5 2.6 5.4 0.5 6.8 4.2 14 7 15 165 3.6 0.1 4 3.3 04/27/2007 19:20:00 4.7 0.8 6.5 3.4 4.6 0.8 6.5 2.6 5 0.8 6.8 3.4 17 6 23 165 3.6 0.2 3.8 3 04/27/2007 19:30:00 4.6 0.7 6.8 3 4.4 0.8 6.8 2.6 4.9 0.7 6.8 3.4 16 7 18 165 3.6 0.1 3.8 3.3 04/27/2007 19:40:00 5.3 0.8 6.5 3.4 5.2 0.8 6.8 3 5.6 0.8 7.2 3.4 16 5 14 165 3.5 0.1 3.8 3 04/27/2007 19:50:00 5.3 1 8.4 3.4 5.5 1 8.4 3.4 5.5 0.8 8.4 3.8 20 6 27 165 3.5 0 3.5 3.3 04/27/2007 20:00:00 6.4 0.9 9.1 4.6 6.5 1 9.5 4.2 6.5 0.9 9.1 4.2 23 8 25 165 3.3 0 3.5 3 04/27/2007 20:10:00 4.6 0.5 6.1 3.4 3.6 1 6.1 1.9 4.9 0.6 6.1 3.8 10 7 7 165 3.1 0.1 3.3 2.6 04/27/2007 20:20:00 4.8 0.4 5.7 3.4 3.1 0.5 4.9 1.9 5.1 0.5 6.5 3.8 4 5 9 165 3 0.1 3.3 2.6 04/27/2007 20:30:00 4.5 0.6 6.1 3.4 3.2 0.8 5.7 1.5 4.8 0.7 6.8 3.4 356 7 351 165 3 0 3.3 2.6 04/27/2007 20:40:00 3.7 0.5 5.7 2.3 2.5 0.7 4.9 1.1 3.9 0.4 5.7 2.6 3 8 355 165 3 0 3.3 2.6 04/27/2007 20:50:00 3.5 0.6 5.3 2.3 2.9 0.9 4.9 0.7 3.7 0.7 5.7 2.3 11 9 14 165 3.2 0 3.3 2.8 04/27/2007 21:00:00 3.5 1 6.5 1.5 3.1 0.9 6.1 1.1 3.5 0.9 6.5 1.9 26 13 14 165 3.2 0 3.5 2.8 04/27/2007 21:10:00 3.6 0.5 4.9 2.6 3.4 0.5 4.9 1.9 3.8 0.5 4.9 2.6 28 13 22 165 3.2 0 3.5 2.8 04/27/2007 21:20:00 3.4 0.7 5.3 1.5 3.2 0.8 4.9 1.1 3.6 0.6 4.9 2.3 23 8 11 165 3.3 0 3.5 3 04/27/2007 21:30:00 3.7 0.5 4.9 2.3 3.8 0.6 5.3 2.3 3.9 0.6 5.3 2.6 27 7 34 165 3.2 0 3.5 3 04/27/2007 21:40:00 3.4 0.4 4.2 2.3 3.5 0.5 4.6 2.3 3.7 0.5 4.9 2.6 26 4 31 165 3.2 0 3.5 2.8 04/27/2007 21:50:00 3.1 0.6 4.6 1.9 3.1 0.7 4.9 1.5 3.3 0.6 4.9 1.9 33 6 28 165 3.2 0 3.5 2.8 04/27/2007 22:00:00 2.8 0.3 3.4 1.9 2.4 0.6 3.4 0.7 2.9 0.4 3.8 1.9 26 9 33 165 3.2 0.1 3.5 2.6 04/27/2007 22:10:00 2.7 0.4 3.4 1.9 2.5 0.5 3.4 0.7 2.8 0.4 3.8 2.3 31 9 16 165 3.2 0.1 3.5 2.6 04/27/2007 22:20:00 3.1 0.4 3.8 1.9 3 0.4 3.8 1.9 3.2 0.3 4.2 2.6 32 4 31 165 3.3 0.1 3.5 2.8 04/27/2007 22:30:00 2.8 0.2 3.4 2.3 2.6 0.3 3.4 1.9 3.1 0.3 3.8 2.3 29 3 37 165 3.2 0.1 3.5 2.8 04/27/2007 22:40:00 3 0.3 3.8 2.3 2.4 0.7 3.8 0.7 3.4 0.2 3.8 2.6 15 14 31 165 3.2 0.1 3.5 2.8 04/27/2007 22:50:00 2.7 0.3 3.8 2.3 1.8 0.5 3.4 0.4 3 0.4 4.2 2.3 351 4 351 165 3 0.2 3.5 2.6 04/27/2007 23:00:00 2.8 0.3 3.8 2.3 2.4 0.6 3.8 0.7 2.9 0.3 3.8 2.3 338 7 349 165 2.9 0 3.3 2.6 04/27/2007 23:10:00 2.8 0.4 3.8 1.5 2 0.8 4.2 0.4 3 0.4 3.8 1.9 350 12 344 165 2.9 0 3.3 2.6 04/27/2007 23:20:00 3.1 0.5 4.6 1.9 2.2 0.6 4.2 0.7 3.3 0.5 4.6 2.3 12 7 23 165 3 0 3.3 2.6 04/27/2007 23:30:00 2.1 0.4 3 1.5 1.4 0.5 2.6 0.4 2.5 0.3 3.4 1.5 11 6 19 165 3 0 3.3 2.8 04/27/2007 23:40:00 0.8 0.4 1.9 0.4 0.6 0.3 1.5 0.4 1.4 0.5 2.6 0.4 19 7 23 165 3 0.1 3.3 2.6 04/27/2007 23:50:00 1.2 0.4 2.3 0.4 1.1 0.4 2.3 0.4 1.8 0.4 2.6 0.7 26 9 34 165 3 0.1 3.3 2.6 04/28/2007 00:00:00 1.9 0.3 2.6 1.1 1.5 0.5 2.3 0.4 2.5 0.2 3 1.9 14 5 10 165 2.9 0 3.3 2.3 04/28/2007 00:10:00 3.6 0.5 4.6 2.3 3.6 0.5 4.6 2.3 3.8 0.4 4.9 2.6 28 6 34 165 2.9 0 3.3 2.6 04/28/2007 00:20:00 4.4 0.4 5.3 3.4 4.5 0.5 5.3 3.4 4.7 0.4 5.7 3.8 32 3 37 165 3 0 3.3 2.8 04/28/2007 00:30:00 4.4 0.3 5.3 3.4 4.6 0.3 5.3 3.8 4.9 0.3 5.7 4.2 24 5 18 165 2.9 0 3 2.8 04/28/2007 00:40:00 4.3 0.3 4.9 3.4 3.5 0.8 5.3 1.9 4.9 0.3 6.1 4.2 13 4 21 165 2.6 0 2.8 2.6 04/28/2007 00:50:00 3.3 0.5 4.2 2.3 2.6 0.5 3.8 1.5 3.9 0.5 4.9 3 12 4 15 165 2.4 0 2.6 2.3 04/28/2007 01:00:00 2 0.4 3 1.1 1.7 0.4 3 1.1 2.6 0.4 3.8 1.9 19 3 18 165 2.5 0 2.8 2.3 04/28/2007 01:10:00 1.3 0.3 2.3 0.7 0.9 0.3 1.9 0.4 1.7 0.3 2.6 1.1 16 2 16 165 2.6 0 2.8 2.6 04/28/2007 01:20:00 1.4 0.3 2.3 0.7 1.2 0.3 2.3 0.4 1.9 0.2 2.6 1.5 21 3 25 165 2.6 0 2.8 2.6 04/28/2007 01:30:00 0.9 0.4 1.5 0.4 0.6 0.3 1.1 0.4 1.4 0.4 1.9 0.7 13 12 25 165 2.9 0 3 2.8 04/28/2007 01:40:00 1.3 0.3 2.3 0.4 0.6 0.3 1.5 0.4 1.6 0.3 2.3 0.7 5 6 12 165 2.7 0 2.8 2.6 04/28/2007 01:50:00 0.8 0.4 1.9 0.4 0.5 0.2 1.1 0.4 1.2 0.4 2.3 0.4 2 8 348 165 2.7 0 2.8 2.6 04/28/2007 02:00:00 1.1 0.3 1.9 0.4 0.7 0.4 1.9 0.4 1.5 0.3 2.6 0.7 10 6 4 165 2.7 0 2.8 2.6 04/28/2007 02:10:00 1.1 0.4 1.9 0.4 1 0.4 1.9 0.4 1.7 0.3 2.6 0.7 20 7 29 165 2.9 0 3.3 2.6 04/28/2007 02:20:00 2 0.6 3.8 1.1 1.9 0.6 3.8 0.7 2.4 0.6 4.2 1.5 27 12 17 165 3.1 0 3.5 2.8 04/28/2007 02:30:00 2.3 0.6 3.8 1.1 2.3 0.6 3.8 1.1 2.5 0.6 4.2 1.5 54 12 48 165 3.3 0.1 3.5 3 04/28/2007 02:40:00 1.6 0.4 3 0.7 1.7 0.4 3 0.7 2.1 0.4 3 1.1 45 11 48 165 3.3 0 3.5 2.8 04/28/2007 02:50:00 1.8 0.5 3.4 0.7 1.9 0.5 3.4 0.7 2.4 0.5 3.8 1.5 39 6 42 165 3.3 0 3.5 2.8 04/28/2007 03:00:00 1.9 0.6 3 0.7 1.9 0.5 3 1.1 2.3 0.5 3.4 1.1 40 9 50 165 3.3 0 3.5 3 04/28/2007 03:10:00 2 0.5 3 0.7 2 0.5 3 0.7 2.4 0.5 3.8 1.1 41 5 31 165 3.2 0 3.5 2.8 04/28/2007 03:20:00 2.4 0.3 3 1.9 2.4 0.3 3 1.9 2.9 0.3 3.4 2.3 38 3 39 165 3 0.1 3.3 2.6 04/28/2007 03:30:00 2.5 0.3 3 1.9 2.4 0.3 3 1.9 3.1 0.2 3.4 2.6 27 5 24 165 3 0.1 3.3 2.6 04/28/2007 03:40:00 2.1 0.3 3 1.5 2 0.3 2.6 1.5 2.7 0.3 3.4 1.9 26 5 25 165 2.9 0.1 3 2.3 04/28/2007 03:50:00 1.5 0.5 2.6 0.4 1.4 0.5 3 0.4 2.2 0.4 3 1.1 37 6 33 165 2.8 0 3 2.1 04/28/2007 04:00:00 1.8 0.4 2.6 1.1 1.7 0.4 2.6 1.1 2.4 0.3 3 1.9 35 4 39 165 2.8 0 3 2.3 04/28/2007 04:10:00 2.7 0.3 3.4 1.9 2.6 0.3 3 1.9 3.2 0.3 3.8 2.6 39 3 39 165 2.7 0 2.8 2.1 04/28/2007 04:20:00 2.3 0.4 3 1.1 2.3 0.3 3 1.5 2.9 0.4 3.8 1.5 29 6 28 165 2.5 0.1 2.8 1.8 04/28/2007 04:30:00 1.2 0.5 2.3 0.4 1.2 0.6 2.6 0.4 2 0.4 3 1.1 15 13 37 165 2.4 0 2.6 1.8 04/28/2007 04:40:00 0.9 0.5 2.3 0.4 1 0.6 2.3 0.4 1.7 0.4 2.6 0.7 22 6 19 165 2.3 0 2.6 1.8 04/28/2007 04:50:00 0.6 0.3 1.5 0.4 1 0.4 1.9 0.4 1.7 0.3 2.3 1.1 32 9 41 165 2.4 0 2.6 1.8 04/28/2007 05:00:00 0.5 0.2 1.5 0.4 0.7 0.4 1.9 0.4 1.3 0.4 2.3 0.4 49 4 42 165 2.4 0 2.8 2.3 04/28/2007 05:10:00 0.4 0 0.4 0.4 0.5 0.3 1.5 0.4 1.2 0.4 1.9 0.4 62 7 165 165 2.4 0 2.6 2.3 04/28/2007 05:20:00 0.7 0.5 2.3 0.4 0.9 0.6 2.3 0.4 1.5 0.8 2.6 0.4 65 8 56 165 2.4 0 2.6 2.3 04/28/2007 05:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.5 0.2 1.5 0.4 78 7 165 165 2.4 0 2.8 2.3 04/28/2007 05:40:00 0.6 0.3 1.1 0.4 1.1 0.4 1.9 0.4 1.3 0.5 1.9 0.4 97 8 100 165 2.6 0 2.8 2.6 04/28/2007 05:50:00 0.4 0 0.4 0.4 0.4 0.1 0.7 0.4 0.9 0.2 1.5 0.4 101 0 165 165 2.6 0 2.8 2.6 04/28/2007 06:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 1 0.3 1.5 0.7 101 0 165 165 2.7 0 2.8 2.6 04/28/2007 06:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 1.2 0.2 1.9 0.7 126 8 165 165 2.7 0 2.8 2.6 04/28/2007 06:20:00 0.4 0 0.4 0.4 0.5 0.3 1.1 0.4 1.3 0.2 1.9 0.7 132 0 165 165 2.7 0 2.8 2.6 04/28/2007 06:30:00 0.5 0.2 1.1 0.4 0.6 0.3 1.5 0.4 1.1 0.3 1.9 0.4 132 0 133 165 2.7 0 2.8 2.6 04/28/2007 06:40:00 0.7 0.1 1.1 0.4 0.7 0.1 1.1 0.4 1.3 0.2 1.5 1.1 152 7 155 165 2.7 0 3 2.6 04/28/2007 06:50:00 0.4 0 0.7 0.4 0.4 0.1 0.7 0.4 1 0.2 1.5 0.4 157 0 158 165 2.7 0 2.8 2.1 04/28/2007 07:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.9 0.3 1.5 0.4 157 0 165 165 2.7 0.2 3 2.3 04/28/2007 07:10:00 0.8 0.2 1.1 0.4 0.7 0.3 1.5 0.4 1.3 0.2 1.9 0.7 156 3 158 165 2.8 0 3 2.3 04/28/2007 07:20:00 0.9 0.2 1.5 0.4 1.1 0.2 1.5 0.7 1.5 0.2 1.9 1.1 148 6 147 165 2.8 0.1 3 2.3 04/28/2007 07:30:00 1.3 0.3 1.9 0.7 1.6 0.3 2.3 1.1 1.7 0.3 2.6 1.1 134 3 136 165 3 0.1 3.3 2.6 04/28/2007 07:40:00 1.5 0.4 2.6 0.7 1.5 0.4 2.3 0.7 1.7 0.4 2.6 0.7 140 8 147 165 3 0 3.3 2.8 04/28/2007 07:50:00 1.4 0.2 2.3 0.7 1.5 0.2 2.3 0.4 1.7 0.2 2.3 0.7 139 10 150 165 3 0 3.3 2.8 04/28/2007 08:00:00 1.8 0.4 3 1.1 1.8 0.4 2.6 1.1 2 0.4 3 0.7 130 7 137 165 3 0.2 3.3 2.3 04/28/2007 08:10:00 2 0.3 3 1.1 1.9 0.3 2.6 1.1 2.2 0.3 3 1.5 128 8 125 165 2.9 0.2 3.3 2.3 04/28/2007 08:20:00 1.5 0.7 3 0.4 1.3 0.7 2.6 0.4 1.7 0.6 3 0.4 133 6 146 165 3 0.1 3.5 2.6 04/28/2007 08:30:00 2 0.5 3 0.7 1.8 0.5 2.6 0.4 2.1 0.5 3 0.7 134 9 145 165 3 0.1 3.5 2.6 04/28/2007 08:40:00 2.2 0.7 3.4 0.7 2 0.8 3.8 0.7 2.3 0.8 3.8 0.7 148 9 159 165 3.1 0.1 3.5 2.8 04/28/2007 08:50:00 2.6 0.4 4.2 1.5 2.3 0.4 3.8 1.1 2.6 0.4 3.8 1.9 148 7 145 165 2.9 0.1 3.3 2.6 04/28/2007 09:00:00 3 0.5 4.2 1.9 2.8 0.5 4.2 1.5 3 0.5 4.2 1.5 156 10 150 165 3.2 0 3.5 2.8 04/28/2007 09:10:00 2.8 0.6 4.6 1.9 2.6 0.5 4.2 1.5 2.9 0.5 4.6 1.5 150 9 157 165 3.4 0 3.5 3 04/28/2007 09:20:00 2.7 0.5 4.2 1.5 2.5 0.5 4.2 1.1 2.8 0.4 4.6 1.9 146 9 148 165 3.4 0 3.5 3.3 04/28/2007 09:30:00 2.5 0.4 3.8 1.5 2.3 0.5 3.4 1.1 2.7 0.5 4.6 1.9 157 8 165 165 3.4 0.1 3.8 2.8 04/28/2007 09:40:00 3.2 0.6 4.6 1.9 3.1 0.5 4.6 1.9 3.3 0.5 4.6 1.9 157 15 150 165 3.6 0 3.8 3.3 04/28/2007 09:50:00 3 0.5 4.6 1.5 2.8 0.5 4.6 1.5 3.2 0.5 4.6 1.9 149 8 157 165 3.7 0 4 3 04/28/2007 10:00:00 3.6 0.5 4.6 1.9 3.4 0.5 4.9 1.9 3.7 0.5 5.7 2.3 153 8 145 165 3.8 0.2 4.3 3.3 04/28/2007 10:10:00 3.8 0.5 5.3 2.6 3.8 0.5 5.3 2.6 4 0.4 4.9 2.6 146 9 158 165 4 0 4.3 3.5 04/28/2007 10:20:00 3.8 0.4 4.9 2.6 3.6 0.4 4.9 2.3 3.9 0.4 4.9 2.6 145 8 146 165 3.6 0.1 3.8 3.5 04/28/2007 10:30:00 3.4 0.5 4.9 1.5 3.4 0.5 4.9 1.9 3.8 0.5 5.3 2.6 146 10 145 165 4 0.2 4.5 3.8 04/28/2007 10:40:00 3 0.5 4.2 1.9 2.9 0.5 4.2 1.5 3.3 0.5 4.6 2.3 146 10 142 165 4 0 4.3 3.8 04/28/2007 10:50:00 2.8 0.7 4.6 1.1 2.7 0.7 4.6 0.7 3 0.6 4.6 1.5 148 10 157 165 4.9 0.3 5.5 4.3 04/28/2007 11:00:00 3.8 0.7 6.1 2.3 3.7 0.7 5.7 1.9 3.9 0.7 6.5 1.9 147 10 136 165 5.4 0.2 6.2 5 04/28/2007 11:10:00 4.1 0.7 5.7 2.3 4 0.7 5.7 2.3 4.3 0.7 5.7 2.3 152 11 154 165 4.9 0.4 5.7 4.3 04/28/2007 11:20:00 4.6 0.6 6.1 2.6 4.4 0.6 6.1 2.6 4.7 0.6 6.8 3 150 7 148 165 4.4 0 5 4.3 04/28/2007 11:30:00 4.9 0.5 6.5 3.4 4.8 0.5 6.1 3 5.2 0.5 6.8 3.8 149 7 144 165 4.6 0.1 4.8 4.3 04/28/2007 11:40:00 4.8 0.5 6.5 3.4 4.7 0.5 6.5 3.4 5 0.5 6.5 3.8 148 6 147 165 4.9 0 5.5 4.8 04/28/2007 11:50:00 5.3 0.5 6.1 3.8 5.1 0.5 6.5 3.4 5.5 0.5 6.8 4.2 152 6 147 165 5 0.2 5.7 4.5 04/28/2007 12:00:00 5.4 0.5 6.8 4.2 5.2 0.5 6.5 3.8 5.6 0.5 6.8 4.2 152 5 158 165 4.6 0.2 5.5 4.3 04/28/2007 12:10:00 4.9 0.5 6.1 3.8 4.9 0.5 6.1 3.8 5.2 0.5 6.5 3.8 149 6 153 165 4.3 0.2 4.8 4 04/28/2007 12:20:00 5 0.5 6.5 3.8 4.8 0.5 6.1 3.4 5.1 0.5 6.5 3.8 151 7 148 165 4.1 0 4.5 4 04/28/2007 12:30:00 5.1 0.4 6.5 4.2 5.2 0.5 6.5 4.2 5.5 0.4 6.5 4.6 154 6 142 165 4.1 0 4.5 4 04/28/2007 12:40:00 5.1 0.5 6.1 3.8 5.1 0.5 6.5 4.2 5.5 0.5 6.8 4.6 148 7 148 165 4.5 0.2 5 4.3 04/28/2007 12:50:00 5.5 0.7 7.6 4.2 5.6 0.7 8 4.2 6 0.6 7.6 4.2 143 8 141 165 4.9 0 5.2 4.8 04/28/2007 13:00:00 6.1 0.7 8.4 4.9 6.1 0.7 8 4.9 6.5 0.7 8.4 4.9 145 6 155 165 4.8 0.1 5 4.5 04/28/2007 13:10:00 6.4 0.6 8.4 4.6 6.4 0.6 8 4.9 6.7 0.6 8 5.3 148 5 142 165 4.4 0.2 4.8 4.3 04/28/2007 13:20:00 6.3 0.6 8.4 4.6 6.4 0.6 8.4 4.6 6.6 0.7 8.8 4.9 139 7 145 165 4.7 0.1 5 4.5 04/28/2007 13:30:00 7 0.5 8.4 5.7 6.9 0.5 8.8 5.3 7.2 0.5 8.4 5.7 137 5 134 165 4.6 0.1 5 4.3 04/28/2007 13:40:00 7.1 0.5 8.8 6.1 7.1 0.5 8.8 5.7 7.3 0.5 8.4 5.3 137 5 146 165 4.5 0.1 4.8 4.3 04/28/2007 13:50:00 7.1 0.5 8.4 6.1 7.1 0.5 8.4 6.1 7.4 0.5 8.8 6.1 140 5 136 165 4.5 0 5 4.3 04/28/2007 14:00:00 7.1 0.5 8.4 5.7 7.1 0.5 8.4 5.7 7.4 0.4 8.4 6.1 141 4 141 165 4.8 0.2 5.2 4.3 04/28/2007 14:10:00 7 0.4 8.4 5.3 6.9 0.4 8.4 5.3 7.1 0.5 8 5.3 138 5 147 165 4.4 0 4.8 4.3 04/28/2007 14:20:00 7 0.4 8.4 5.7 7.1 0.4 8 5.7 7.2 0.5 8.4 5.7 138 6 128 165 4.3 0 4.5 4.3 04/28/2007 14:30:00 8 0.5 9.1 6.5 8 0.5 9.1 6.5 8.1 0.5 9.1 6.1 140 3 141 165 4.4 0.1 4.8 4 04/28/2007 14:40:00 8.4 0.6 9.5 6.8 8.4 0.5 9.5 6.8 8.3 0.7 9.5 6.1 138 3 135 165 4.1 0 4.5 4 04/28/2007 14:50:00 8.8 0.5 9.9 6.8 8.8 0.5 9.9 6.8 8.6 0.6 9.5 6.8 137 5 128 165 4.2 0.1 4.5 4 04/28/2007 15:00:00 8.9 0.6 9.9 6.8 8.8 0.5 10.3 7.2 8.6 0.7 10.7 6.5 135 4 131 165 4 0 4.3 3.8 04/28/2007 15:10:00 9.3 0.4 10.3 8 9.3 0.4 10.3 8 9.3 0.5 10.3 7.6 138 4 121 165 3.9 0 4.3 3.8 04/28/2007 15:20:00 9.2 0.4 10.3 7.6 9.1 0.4 10.3 7.2 9.1 0.5 9.9 7.2 138 3 142 165 4 0 4.3 3.8 04/28/2007 15:30:00 9 0.4 9.9 7.6 8.9 0.4 9.9 7.6 8.9 0.5 9.9 7.2 138 4 139 165 4.1 0.1 4.5 3.8 04/28/2007 15:40:00 9.1 0.6 10.3 6.8 9.1 0.5 10.7 7.2 9.2 0.6 10.3 7.2 138 4 135 165 3.9 0 4.3 3.5 04/28/2007 15:50:00 8.8 0.5 10.3 7.2 8.8 0.5 10.3 7.6 8.7 0.6 10.3 6.8 137 4 138 165 3.9 0.1 4.3 3.5 04/28/2007 16:00:00 8.3 0.7 9.9 6.1 8.3 0.6 9.9 6.5 8.3 0.8 10.3 6.1 143 6 141 165 4.2 0 4.5 3.8 04/28/2007 16:10:00 8.3 0.6 9.9 6.8 8.3 0.6 9.9 6.8 8.2 0.8 10.3 6.1 138 7 132 165 4.3 0 4.5 4.3 04/28/2007 16:20:00 9 0.6 10.3 7.2 9 0.5 10.3 7.2 8.9 0.7 10.3 6.5 135 4 136 165 4 0 4.3 3.5 04/28/2007 16:30:00 8.7 0.7 10.3 6.5 8.7 0.7 10.3 6.5 8.6 0.7 10.3 6.5 137 5 135 165 4.1 0.1 4.5 3.5 04/28/2007 16:40:00 8.6 0.6 9.9 6.1 8.6 0.6 9.9 6.5 8.6 0.7 9.9 6.1 140 5 144 165 4 0 4.3 3.5 04/28/2007 16:50:00 8.1 0.6 9.9 6.5 8.2 0.6 9.9 6.5 8.3 0.6 9.9 6.1 141 6 144 165 4.1 0 4.3 3.5 04/28/2007 17:00:00 8.6 0.5 9.9 6.8 8.6 0.5 9.5 6.8 8.7 0.6 9.9 6.8 140 5 138 165 4 0 4.3 3.8 04/28/2007 17:10:00 8.3 0.7 9.9 6.1 8.3 0.6 9.9 6.5 8.5 0.6 10.3 6.8 140 5 129 165 3.9 0 4.3 3.5 04/28/2007 17:20:00 8.7 0.6 10.3 6.8 8.7 0.6 10.3 6.8 8.7 0.6 10.7 7.2 141 4 139 165 3.6 0.1 4 3 04/28/2007 17:30:00 7.6 0.8 9.1 5.7 7.7 0.7 9.1 5.3 7.7 0.7 9.9 5.7 141 8 142 165 3.8 0.1 4.3 3 04/28/2007 17:40:00 7.5 0.6 8.8 6.1 7.7 0.5 8.8 6.1 7.6 0.6 9.1 6.1 132 8 139 165 3.7 0.1 4.3 3.3 04/28/2007 17:50:00 7.6 0.9 9.1 5.3 7.7 0.8 9.1 5.7 7.7 0.8 9.5 4.9 142 7 148 165 3.6 0.2 3.8 3 04/28/2007 18:00:00 9.3 0.6 10.3 7.2 9.3 0.5 10.3 7.6 9.3 0.6 10.7 6.5 140 3 140 165 3.5 0.1 3.8 2.8 04/28/2007 18:10:00 9.4 0.7 10.7 6.5 9.4 0.7 10.7 6.1 9.4 0.7 10.7 6.8 140 4 135 165 3.3 0 3.5 2.8 04/28/2007 18:20:00 8.4 0.6 9.9 5.7 8.5 0.6 10.3 5.7 8.2 0.7 9.9 6.1 135 7 133 165 3.3 0 3.5 3 04/28/2007 18:30:00 8.7 0.7 10.3 6.1 8.8 0.6 10.7 6.8 8.6 0.7 10.3 6.8 133 5 133 165 3.1 0.1 3.3 2.6 04/28/2007 18:40:00 8.7 0.6 10.3 7.2 8.9 0.6 10.3 7.2 8.5 0.8 10.3 6.1 129 5 130 165 3 0.1 3.3 2.6 04/28/2007 18:50:00 9 0.7 10.7 6.8 9 0.6 10.7 6.8 9.1 0.7 10.7 6.5 139 6 142 165 3 0.1 3.3 2.3 04/28/2007 19:00:00 8.9 0.5 10.7 7.2 9 0.5 10.3 7.2 8.8 0.6 10.7 6.8 141 6 140 165 3 0.1 3.3 2.3 04/28/2007 19:10:00 7.2 0.7 9.1 5.7 7.4 0.6 9.1 6.1 7.4 0.7 9.5 5.7 145 5 144 165 3 0 3.3 2.8 04/28/2007 19:20:00 7.2 0.5 8.4 6.1 7.4 0.5 8.8 6.1 7.3 0.5 8.4 5.7 140 5 135 165 3 0 3.3 2.8 04/28/2007 19:30:00 7.1 0.4 8.4 6.1 7.3 0.4 8.4 6.5 7.4 0.5 8.8 6.1 144 5 133 165 2.9 0 3.3 2.6 04/28/2007 19:40:00 7.6 0.8 9.1 5.7 7.8 0.7 9.1 6.1 7.7 0.8 9.5 5.7 141 7 131 165 2.9 0 3 2.6 04/28/2007 19:50:00 6.1 0.6 7.2 4.9 6.4 0.6 8 4.9 6.3 0.7 7.6 4.2 134 6 135 165 2.8 0 3 2.6 04/28/2007 20:00:00 5.6 0.5 7.2 4.6 5.9 0.5 7.2 4.9 5.8 0.5 8 3.8 128 6 127 165 2.7 0.1 3 2.3 04/28/2007 20:10:00 5.7 0.4 6.8 4.6 6.1 0.5 7.2 4.9 5.9 0.5 7.2 4.6 128 7 135 165 2.7 0.1 3 2.3 04/28/2007 20:20:00 6.4 0.8 8 3.8 6.8 0.7 8.8 4.9 6.5 0.8 8.4 4.6 127 6 121 165 2.7 0.1 3 2.1 04/28/2007 20:30:00 6.8 0.8 8.8 4.9 7.2 0.7 8.8 5.3 7 0.7 8.8 5.3 130 5 123 165 2.6 0.1 3 2.3 04/28/2007 20:40:00 7.9 1 10.3 5.3 8 0.9 10.3 5.3 7.9 1 10.3 4.9 139 7 145 165 2.6 0.1 2.8 2.3 04/28/2007 20:50:00 8.3 1 10.3 5.7 8.3 0.9 10.3 5.7 8.4 0.8 10.3 6.5 149 8 145 165 2.6 0.2 2.8 2.3 04/28/2007 21:00:00 6.2 0.4 7.2 5.3 6.4 0.4 7.2 5.3 6.5 0.4 7.6 5.7 155 6 156 165 2.4 0 2.8 2.1 04/28/2007 21:10:00 5.3 0.5 6.5 4.2 5.6 0.4 6.5 4.6 5.7 0.4 6.8 4.6 148 5 140 165 2.3 0 2.6 1.8 04/28/2007 21:20:00 6.3 0.5 7.6 5.3 6.5 0.4 7.6 5.3 6.7 0.5 8 5.3 148 5 141 165 2.3 0 2.6 2.1 04/28/2007 21:30:00 6.1 0.6 8 4.9 6.4 0.6 8 4.9 6.5 0.6 8 5.3 144 5 145 165 2.2 0 2.3 1.8 04/28/2007 21:40:00 4.7 0.4 6.1 3.8 5 0.4 6.1 4.2 5.1 0.4 6.5 4.2 140 5 151 165 2.2 0 2.6 1.8 04/28/2007 21:50:00 4.2 0.4 5.3 3 4.5 0.5 5.3 3.4 4.5 0.4 5.7 3 136 6 134 165 2.2 0 2.3 1.8 04/28/2007 22:00:00 3.7 0.5 4.9 2.6 3.9 0.5 5.3 2.6 4 0.4 4.9 2.6 133 7 133 165 2.1 0 2.6 1.8 04/28/2007 22:10:00 3.9 0.3 4.9 3 4.3 0.3 5.3 3.4 4.3 0.4 4.9 3.4 125 5 121 165 2.1 0 2.3 1.8 04/28/2007 22:20:00 4.6 0.8 6.5 2.6 5 0.7 6.5 2.6 4.9 0.6 6.5 3 127 8 139 165 2.1 0 2.3 1.8 04/28/2007 22:30:00 4.5 0.5 5.7 3.4 4.9 0.5 6.1 3.8 4.7 0.6 6.1 3 115 8 100 165 2.1 0 2.3 1.8 04/28/2007 22:40:00 6.1 0.6 7.2 4.2 6.6 0.6 7.6 4.9 6.4 0.7 8.4 4.6 114 5 112 165 2.1 0 2.3 1.8 04/28/2007 22:50:00 6.3 0.5 7.2 4.6 6.8 0.5 8 4.9 6.4 0.5 8 4.6 119 3 121 165 2.1 0 2.3 1.8 04/28/2007 23:00:00 7.5 0.8 9.9 5.7 7.9 0.7 9.5 6.5 7.4 0.9 9.1 4.9 113 5 116 165 1.9 0.2 2.6 1.1 04/28/2007 23:10:00 6.7 0.6 8.8 4.9 7.2 0.5 9.1 5.3 6.6 0.7 8.8 4.9 112 5 116 165 1.8 0.1 2.1 1.4 04/28/2007 23:20:00 7.7 0.6 9.5 5.3 8.2 0.6 9.5 5.7 7.5 0.7 9.1 5.3 108 3 111 165 2.1 0 2.3 1.4 04/28/2007 23:30:00 8.5 0.7 9.9 5.7 8.9 0.6 10.3 6.1 8.3 0.8 9.9 5.3 106 5 102 165 2.1 0 2.3 1.6 04/28/2007 23:40:00 8.4 0.4 9.5 6.5 8.6 0.4 9.9 6.8 7.8 0.7 9.5 5.3 107 4 116 165 2.3 0.1 2.6 1.8 04/28/2007 23:50:00 8.2 0.7 9.9 5.3 8.5 0.7 10.3 6.1 7.7 0.9 10.3 5.3 101 4 114 165 2.3 0.2 2.6 1.8 04/29/2007 00:00:00 8.9 0.6 10.3 6.5 9.2 0.6 10.7 6.5 8.6 0.8 10.3 6.1 106 3 108 165 2.3 0.1 2.6 1.6 04/29/2007 00:10:00 8.7 0.7 10.3 6.5 9 0.6 10.7 6.8 8.5 0.9 9.9 6.1 105 4 107 165 2.3 0.1 2.6 1.6 04/29/2007 00:20:00 8.9 0.7 11.1 4.9 9.2 0.6 11.1 6.1 8.5 0.8 9.9 6.1 106 5 104 165 2.4 0.1 2.6 1.8 04/29/2007 00:30:00 8.6 0.6 10.3 6.8 8.9 0.6 10.3 7.2 8.2 0.8 9.9 5.3 109 5 110 165 2.4 0.1 2.6 1.8 04/29/2007 00:40:00 8.4 0.7 9.9 6.5 8.7 0.6 10.3 6.8 8.1 0.8 9.5 5.7 110 5 101 165 2.4 0.1 2.6 1.8 04/29/2007 00:50:00 8.6 0.6 10.3 6.8 8.9 0.5 10.7 7.2 8.5 0.7 10.7 6.1 110 5 109 165 2.4 0.1 2.6 1.8 04/29/2007 01:00:00 9 0.7 11.1 6.8 9.2 0.7 11.1 6.5 8.7 0.8 10.3 6.5 110 4 114 165 2.4 0.1 2.8 1.8 04/29/2007 01:10:00 9.1 0.8 11.5 6.5 9.4 0.7 11.5 6.8 8.7 0.9 11.1 6.5 109 4 110 165 2.4 0.1 2.6 1.8 04/29/2007 01:20:00 9.8 0.8 11.8 7.6 10 0.7 12.2 7.6 9.5 0.8 12.2 6.5 110 5 109 165 2.4 0.1 2.6 1.8 04/29/2007 01:30:00 9.4 0.9 12.2 6.8 9.6 0.9 12.2 6.8 9.2 0.9 12.2 6.1 123 16 119 165 2.4 0.1 2.8 1.8 04/29/2007 01:40:00 7.7 1.1 9.9 5.3 7.9 1 9.9 5.7 7.7 1 9.9 4.6 136 8 144 165 2 0 2.3 1.8 04/29/2007 01:50:00 5.4 0.8 9.1 3.4 5.8 0.8 9.5 3.4 5.5 0.8 8 3.4 128 7 125 165 2.1 0 2.3 1.8 04/29/2007 02:00:00 6.1 0.6 7.6 4.6 6.4 0.6 7.6 4.2 6.5 0.5 7.6 4.6 148 7 160 165 2.3 0 2.6 1.8 04/29/2007 02:10:00 8 1.3 10.7 3.8 8.2 1.3 10.7 4.2 7.7 1.3 11.1 3.8 118 9 119 165 2.5 0 2.8 2.1 04/29/2007 02:20:00 8.3 0.7 10.3 6.1 8.5 0.7 10.7 6.5 8 0.8 10.3 5.3 114 5 123 165 2.6 0 2.8 2.1 04/29/2007 02:30:00 8.5 0.6 9.9 6.5 8.7 0.5 10.3 7.2 8.3 0.6 9.9 5.7 113 5 121 165 2.6 0 2.8 2.3 04/29/2007 02:40:00 8.5 0.9 10.7 5.7 8.7 0.8 11.1 6.1 8.2 1 10.7 5.3 106 7 95 165 2.5 0 2.8 2.3 04/29/2007 02:50:00 8.8 0.6 10.3 6.5 9.1 0.6 10.7 6.8 8.5 0.7 10.3 5.7 101 4 105 165 2.5 0 2.8 2.3 04/29/2007 03:00:00 9.4 0.6 10.7 7.6 9.7 0.5 11.1 8.4 9 0.7 10.7 6.5 102 5 98 165 2.7 0 2.8 2.1 04/29/2007 03:10:00 9.3 0.7 11.5 7.6 9.5 0.6 11.5 7.6 9 0.7 10.7 7.2 104 4 95 165 2.7 0 2.8 2.6 04/29/2007 03:20:00 9.2 0.7 11.1 6.5 9.4 0.7 11.1 6.8 8.8 0.8 10.7 6.1 101 5 102 165 2.7 0 2.8 2.3 04/29/2007 03:30:00 9.2 0.6 10.7 7.2 9.5 0.6 11.1 7.6 8.9 0.7 10.7 6.5 98 6 100 165 2.8 0 3 2.1 04/29/2007 03:40:00 8.6 1.6 12.2 4.9 8.9 1.5 12.6 5.7 8.4 1.4 12.2 4.6 108 10 97 165 2.5 0.1 2.8 2.3 04/29/2007 03:50:00 10.3 1.1 13.3 7.6 10.6 1.1 13.3 8 9.9 1.2 13 6.8 103 6 99 165 2.8 0 3 2.6 04/29/2007 04:00:00 10.4 1.1 13 8 10.6 1.1 13.7 8 10.1 1.2 13.3 7.2 107 9 115 165 2.8 0 3 2.6 04/29/2007 04:10:00 9.6 1.6 13.3 5.7 9.9 1.5 13.7 6.5 9.1 1.5 13 5.7 110 9 102 165 2.7 0 3 2.6 04/29/2007 04:20:00 11.8 1.2 14.1 8 12 1.2 14.9 8.4 11 1.4 14.5 7.2 106 8 105 165 2.9 0 3 2.8 04/29/2007 04:30:00 12 1 14.5 8 12.2 1.1 14.5 8.4 11.5 1.3 14.1 8 108 6 101 165 2.9 0 3 2.8 04/29/2007 04:40:00 11.4 1.3 14.5 8 11.6 1.3 14.9 7.2 10.9 1.4 14.1 6.5 108 7 106 165 2.9 0 3 2.6 04/29/2007 04:50:00 10.9 0.9 13 8 11.2 1 13.7 7.2 10.3 1 12.6 6.8 103 7 91 165 2.7 0 3 2.6 04/29/2007 05:00:00 10.6 1 12.6 7.2 10.8 1 13.3 7.6 10 1.1 12.6 7.2 101 6 105 165 2.7 0 3 2.6 04/29/2007 05:10:00 10.3 1 13 6.5 10.6 1 13 7.2 9.8 1.1 12.6 6.1 101 6 103 165 2.8 0 3 2.6 04/29/2007 05:20:00 10.8 0.9 13.3 8.4 11.1 1 14.1 8.4 10.3 1.1 13.3 6.8 98 6 97 165 2.7 0 2.8 2.3 04/29/2007 05:30:00 10.4 1 12.6 6.8 10.7 1 13 7.2 9.8 1 12.2 7.2 95 6 99 165 2.7 0 2.8 2.3 04/29/2007 05:40:00 11.4 1.1 14.9 8.4 11.7 1.1 15.3 8.8 10.9 1.2 14.5 7.2 97 6 99 165 2.7 0 2.8 2.3 04/29/2007 05:50:00 11.5 1.1 14.1 8 11.7 1.1 14.9 8.4 10.6 1.2 13.7 7.2 100 6 102 165 2.7 0 2.8 2.3 04/29/2007 06:00:00 11.6 1.3 14.9 7.6 11.8 1.4 14.9 7.6 10.9 1.5 14.5 6.8 103 7 96 165 2.6 0.2 3.3 1.8 04/29/2007 06:10:00 9.6 0.9 11.8 6.8 9.8 0.9 12.2 7.2 9.2 1 11.8 6.5 104 7 97 165 2.2 0 2.3 1.6 04/29/2007 06:20:00 10.7 0.9 13.3 8 10.9 0.9 13.7 8 10 1.1 13.3 7.2 104 7 101 165 2.2 0 2.6 1.8 04/29/2007 06:30:00 10 1.1 13.3 6.5 10.4 1.1 13.3 7.2 9.6 1.2 13 6.5 91 8 105 165 2.2 0 2.6 1.8 04/29/2007 06:40:00 10.1 1 12.2 6.8 10.4 1.1 13 7.6 9.4 1.1 11.8 6.5 88 7 83 165 1.8 0 2.1 1.6 04/29/2007 06:50:00 10.7 0.9 12.6 7.2 11 0.9 12.6 7.6 9.9 1 12.2 7.2 93 5 105 165 2.1 0 2.3 1.8 04/29/2007 07:00:00 9.8 0.9 12.2 6.5 10.1 0.9 12.2 7.2 9.1 1 11.8 6.5 92 6 97 165 2.4 0 2.6 2.1 04/29/2007 07:10:00 10.3 0.9 12.6 7.2 10.6 0.9 13 7.6 9.5 1.1 12.6 6.5 91 6 90 165 2.4 0 2.6 2.3 04/29/2007 07:20:00 10.5 1.1 12.6 7.6 10.9 1.1 13 8 10 1.1 12.6 7.2 94 7 95 165 2.4 0 2.6 2.3 04/29/2007 07:30:00 11 1.1 13.7 7.2 11.3 1.1 14.1 7.6 10.6 1.2 13 5.7 101 8 92 165 2.5 0 2.8 2.3 04/29/2007 07:40:00 11 1.1 14.5 8 11.3 1.1 14.9 7.6 10.3 1.3 14.1 6.8 98 8 84 165 2.6 0 2.8 2.6 04/29/2007 07:50:00 11.8 1.5 14.9 7.6 12.1 1.5 15.6 8 11.1 1.7 14.9 6.1 98 6 99 165 2.6 0 2.8 2.3 04/29/2007 08:00:00 11.7 1.1 14.1 8.4 12 1.1 14.9 8.4 11 1.2 13.7 7.6 97 7 97 165 2.5 0.1 3 2.3 04/29/2007 08:10:00 12.5 0.9 14.9 9.5 12.8 1 14.9 9.1 11.9 1.2 14.5 8.4 100 6 97 165 2.5 0 2.8 2.3 04/29/2007 08:20:00 12.4 1.2 15.3 8 12.7 1.2 15.3 7.6 11.5 1.3 14.5 7.6 100 7 98 165 2.6 0 2.8 2.3 04/29/2007 08:30:00 11.7 1.2 14.9 8.4 11.9 1.3 15.3 8.4 11 1.3 14.5 7.2 100 6 104 165 2.7 0 2.8 2.6 04/29/2007 08:40:00 10.5 1.1 13 8 10.8 1.1 13.3 8 9.9 1.1 13.3 6.5 94 8 94 165 2.7 0 2.8 2.6 04/29/2007 08:50:00 10.9 1 13.7 6.5 11.2 1 13.7 8 10.2 1.2 13 6.8 93 7 99 165 2.7 0 2.8 2.3 04/29/2007 09:00:00 11.3 1 13.7 8.8 11.6 1 14.1 8.4 10.7 1.1 13 6.8 96 8 99 165 2.7 0 2.8 2.3 04/29/2007 09:10:00 10.3 1.2 13 6.8 10.5 1.2 13 7.2 9.8 1.2 12.2 6.8 104 8 108 165 2.7 0 2.8 2.3 04/29/2007 09:20:00 10.4 1.5 14.9 6.8 10.6 1.6 15.3 7.2 10 1.7 14.9 6.1 105 8 114 165 2.7 0 3 2.3 04/29/2007 09:30:00 10.9 1.3 13.7 7.2 11.1 1.3 13.7 7.6 10.3 1.3 13 6.8 104 6 110 165 2.9 0 3 2.6 04/29/2007 09:40:00 10.3 1 13 7.2 10.5 1.1 13 7.2 9.6 1.1 12.2 6.8 101 9 87 165 2.9 0 3 2.3 04/29/2007 09:50:00 10.7 1.2 13.7 7.6 10.8 1.2 13.3 6.8 9.9 1.3 12.6 6.8 97 6 102 165 2.9 0 3 2.8 04/29/2007 10:00:00 10.5 1.2 13.3 6.8 10.7 1.2 13.7 7.2 10 1.2 13 6.1 94 7 94 165 3 0 3.3 2.8 04/29/2007 10:10:00 10.7 1.2 13 7.2 10.9 1.2 13.3 7.2 10.1 1.3 13.3 6.1 95 8 91 165 2.9 0 3.3 2.6 04/29/2007 10:20:00 11.4 1.3 15.3 8.8 11.6 1.3 15.3 8.8 10.7 1.4 13.7 6.8 98 8 99 165 2.9 0 3 2.1 04/29/2007 10:30:00 11.4 1.2 15.3 7.6 11.5 1.2 14.9 7.6 10.9 1.3 14.9 6.8 104 9 99 165 2.9 0 3 2.6 04/29/2007 10:40:00 10.5 1.1 13.7 7.2 10.7 1.1 13.7 7.6 10.1 1.2 13.3 6.8 101 9 90 165 2.8 0 3 2.6 04/29/2007 10:50:00 10.4 1.2 13.7 7.2 10.6 1.2 13.7 7.6 10.2 1.3 13.3 6.8 112 8 112 165 2.7 0 3 2.6 04/29/2007 11:00:00 9.8 1.1 13.3 6.8 9.8 1.2 13.3 6.8 9.6 1.1 12.2 6.5 121 9 98 165 2.8 0 3.3 2.6 04/29/2007 11:10:00 9.5 0.9 12.2 6.1 9.4 0.9 13 6.8 9.3 1 12.6 6.5 127 9 112 165 2.9 0 3 2.3 04/29/2007 11:20:00 11.5 1 13.3 7.6 11.4 1 13.7 8 11.5 1 13.7 8.8 127 8 116 165 2.7 0 3 2.3 04/29/2007 11:30:00 10.2 0.9 12.2 7.6 10.2 1 13 7.2 9.8 1 12.2 7.2 123 8 112 165 2.7 0 3 2.1 04/29/2007 11:40:00 9.8 1.3 12.2 6.1 9.9 1.3 12.6 6.5 9.4 1.3 12.6 6.5 117 11 125 165 2.6 0 2.8 2.3 04/29/2007 11:50:00 9 1.1 12.6 6.1 9.1 1.1 12.6 5.7 8.8 1.2 12.6 5.7 113 8 112 165 2.8 0.1 3.3 2.6 04/29/2007 12:00:00 10 0.9 11.8 7.2 10.1 1 12.6 7.6 9.6 1 12.6 7.6 112 6 102 165 2.9 0.1 3 2.3 04/29/2007 12:10:00 9.6 1.4 13 5.7 9.7 1.4 13.3 6.1 9.2 1.4 13 5.3 114 8 119 165 2.9 0.1 3 2.6 04/29/2007 12:20:00 9.2 1.3 12.6 5.3 9.4 1.3 13 5.7 8.9 1.2 11.8 5.7 100 8 99 165 3 0 3.3 2.8 04/29/2007 12:30:00 9.9 1.2 13.3 6.1 10.1 1.3 13.7 6.5 9.5 1.2 13.7 6.5 100 9 100 165 3 0 3.3 2.6 04/29/2007 12:40:00 9.5 1.1 11.8 6.5 9.6 1.2 11.8 6.5 9 1.2 11.8 5.7 104 9 105 165 3.1 0 3.5 2.8 04/29/2007 12:50:00 9.1 1.3 12.6 5.3 9.3 1.3 12.6 5.7 8.7 1.3 11.5 6.1 104 8 102 165 3 0.1 3.3 2.6 04/29/2007 13:00:00 8.5 1.2 11.5 4.9 8.6 1.2 11.5 5.3 8.1 1.2 11.5 5.3 107 9 87 165 3.2 0 3.5 2.6 04/29/2007 13:10:00 9.3 1.3 13 5.7 9.4 1.3 13.3 6.1 9 1.2 11.8 5.3 102 9 101 165 3.1 0.1 3.5 2.6 04/29/2007 13:20:00 8.8 1.5 14.1 5.3 8.9 1.5 14.5 5.7 8.5 1.6 13.7 4.9 107 8 92 165 3 0 3.3 2.8 04/29/2007 13:30:00 8.1 1.1 10.7 4.9 8.2 1.1 11.1 4.2 7.7 1.1 10.3 4.9 105 9 98 165 3 0.1 3.3 2.6 04/29/2007 13:40:00 8.6 1.6 12.2 5.3 8.8 1.6 13 5.7 8.4 1.5 11.8 5.3 110 9 106 165 3 0.1 3.3 2.6 04/29/2007 13:50:00 8.7 1.3 12.2 5.3 8.9 1.3 12.2 6.1 8.3 1.3 11.8 4.9 108 10 99 165 3 0.1 3.3 2.6 04/29/2007 14:00:00 8.7 1.3 11.5 4.9 8.8 1.3 11.8 5.3 8.3 1.4 11.5 4.6 105 10 105 165 3 0.1 3.5 2.6 04/29/2007 14:10:00 9.3 1.4 13.3 6.1 9.4 1.4 13.7 6.5 8.8 1.5 13.3 6.1 110 8 102 165 3 0.2 3.3 2.3 04/29/2007 14:20:00 10.3 1.3 13.7 6.5 10.5 1.3 13.7 6.8 10 1.4 14.1 6.1 113 7 116 165 2.9 0.1 3 2.3 04/29/2007 14:30:00 9.6 1.3 12.2 5.7 9.8 1.3 12.6 5.3 9.3 1.5 12.6 4.2 113 9 111 165 2.9 0.1 3.3 2.3 04/29/2007 14:40:00 9.9 0.9 13 7.6 10.1 1 12.6 7.6 9.5 1 12.6 7.2 109 8 105 165 2.9 0.2 3.3 2.3 04/29/2007 14:50:00 8.9 1.1 11.8 4.9 9.1 1.2 11.8 4.9 8.6 1.2 11.5 5.3 105 7 96 165 3.2 0 3.5 2.8 04/29/2007 15:00:00 8.9 1 11.8 6.8 9 1 12.2 6.8 8.5 1.1 11.5 6.1 103 8 114 165 3.2 0 3.5 2.6 04/29/2007 15:10:00 8.8 1.1 11.8 5.7 9 1.1 12.2 6.1 8.3 1.1 11.5 4.9 102 8 98 165 3 0.1 3.3 2.6 04/29/2007 15:20:00 8.7 1 11.5 5.7 8.9 1 11.8 6.1 8.4 1.1 11.8 6.1 100 7 96 165 3 0.1 3.3 2.6 04/29/2007 15:30:00 8.2 1.3 11.1 4.9 8.5 1.2 11.5 5.7 8.2 1.1 11.1 5.3 101 8 104 165 3.2 0 3.3 2.8 04/29/2007 15:40:00 8 1.2 10.7 3.8 8.2 1.2 11.1 4.9 7.9 1.1 10.7 4.9 94 8 99 165 3 0.1 3.3 2.6 04/29/2007 15:50:00 8.6 1 11.1 6.1 8.8 1 11.5 6.1 8.1 1.2 11.1 5.7 95 7 91 165 2.9 0 3.3 2.6 04/29/2007 16:00:00 7.6 1.2 10.7 4.9 7.9 1.1 10.7 5.3 7.5 1.1 10.3 4.6 99 9 101 165 3 0 3.3 2.8 04/29/2007 16:10:00 7.9 1 10.3 4.9 8.1 1 10.7 5.3 7.6 1 9.9 4.9 95 8 93 165 3 0.1 3.3 2.6 04/29/2007 16:20:00 7.8 0.9 10.3 4.9 8 0.9 10.3 5.3 7.6 0.9 9.5 4.9 95 8 101 165 2.9 0 3.3 2.6 04/29/2007 16:30:00 7.7 1 9.9 4.6 8 0.9 10.3 4.6 7.6 0.9 9.5 5.3 94 7 88 165 2.9 0.1 3.3 2.3 04/29/2007 16:40:00 7.7 1 9.9 4.9 8 1 9.9 4.9 7.6 1 9.5 4.9 90 7 84 165 2.8 0.1 3 2.1 04/29/2007 16:50:00 7.4 1 9.9 4.9 7.6 1 9.9 4.9 7.2 1 9.5 4.9 89 9 85 165 2.8 0.1 3 2.1 04/29/2007 17:00:00 7.6 1.1 9.9 4.9 7.9 1 10.3 5.3 7.6 1 9.5 4.9 86 7 83 165 2.7 0 3.3 2.6 04/29/2007 17:10:00 7.5 0.9 9.1 4.6 7.8 0.9 9.5 5.3 7.4 0.9 9.5 4.9 83 7 87 165 2.7 0 2.8 2.6 04/29/2007 17:20:00 6.6 1 9.5 4.2 6.9 1 9.9 4.6 6.6 1 9.1 4.2 74 9 78 165 2.8 0 3 2.6 04/29/2007 17:30:00 6.1 1.1 9.1 3.8 6.4 1.1 9.5 4.2 6.3 1 9.1 3.8 76 9 71 165 2.7 0 2.8 2.6 04/29/2007 17:40:00 6.4 1.1 9.1 3.4 6.7 1.1 9.5 3.8 6.6 1 9.5 3.8 73 9 78 165 2.6 0.1 2.8 2.3 04/29/2007 17:50:00 7.4 1.1 10.3 4.6 7.7 1.1 10.3 5.3 7.5 1.1 10.3 4.2 68 8 68 165 2.4 0 2.6 2.3 04/29/2007 18:00:00 7 1 9.9 4.6 7.3 0.9 9.9 4.9 7.1 0.9 9.9 4.6 69 9 74 165 2.4 0.1 2.6 1.8 04/29/2007 18:10:00 7.6 1.1 10.7 5.3 7.9 1 10.7 5.3 7.4 1 9.9 5.7 72 9 81 165 2.4 0.1 2.6 1.8 04/29/2007 18:20:00 6.9 1.1 10.3 4.6 7.2 1.1 10.3 4.6 6.9 1 9.1 4.6 66 7 64 165 2.4 0.1 2.6 1.8 04/29/2007 18:30:00 7.3 1.1 10.7 4.2 7.6 1.1 11.1 4.6 7.3 1 10.7 4.9 65 9 59 165 2.4 0.1 2.6 1.8 04/29/2007 18:40:00 7.3 1.3 11.1 4.9 7.6 1.2 11.8 4.9 7.4 1.1 11.1 4.6 66 9 65 165 2.4 0.1 2.6 1.8 04/29/2007 18:50:00 7.4 1.1 10.3 5.3 7.6 1.1 10.7 5.3 7.2 1 10.3 4.9 65 8 73 165 2.3 0 2.6 1.8 04/29/2007 19:00:00 7 1.2 9.5 4.2 7.3 1.1 9.9 4.6 7.2 1.1 9.5 4.2 65 8 67 165 2.4 0 2.6 1.8 04/29/2007 19:10:00 7.6 1.2 10.7 4.9 7.8 1.2 11.1 4.9 7.6 1.1 10.3 4.9 60 10 58 165 2.4 0.1 2.6 1.8 04/29/2007 19:20:00 7.5 1.5 11.5 4.6 7.7 1.5 11.5 4.6 7.4 1.2 11.1 4.2 61 10 48 165 2.3 0 2.6 1.8 04/29/2007 19:30:00 7.6 1.3 10.7 4.2 7.8 1.3 10.7 4.6 7.5 1.1 10.3 4.2 62 9 60 165 2.3 0 2.6 1.8 04/29/2007 19:40:00 7.4 1.8 12.6 3.8 7.6 1.9 12.6 4.2 7.4 1.7 12.6 4.2 59 9 52 165 2.3 0 2.6 1.6 04/29/2007 19:50:00 7.5 1.5 11.5 4.2 7.7 1.5 12.2 4.2 7.6 1.4 11.8 4.2 59 10 73 165 2.3 0 2.6 1.8 04/29/2007 20:00:00 8.1 1.4 11.5 4.9 8.3 1.5 11.8 4.9 8 1.3 11.8 4.9 60 8 61 165 2.3 0 2.6 1.8 04/29/2007 20:10:00 7.9 1.4 11.5 4.6 8 1.4 11.1 4.6 7.8 1.5 11.1 4.6 59 10 58 165 2.3 0 2.6 2.3 04/29/2007 20:20:00 8.1 1.4 11.5 4.9 8.2 1.4 11.8 5.3 7.8 1.3 10.7 4.9 58 9 62 165 2.3 0 2.6 2.1 04/29/2007 20:30:00 7.9 1.7 12.6 4.2 8 1.7 12.6 4.6 7.8 1.5 12.6 4.9 56 10 63 165 2.3 0 2.6 2.1 04/29/2007 20:40:00 8.7 1.5 13.3 5.7 8.9 1.5 13.3 6.1 8.7 1.4 13.3 5.7 60 9 58 165 2.3 0 2.6 2.1 04/29/2007 20:50:00 8.2 1.5 11.5 4.6 8.4 1.5 11.8 4.6 8.2 1.5 11.5 5.3 61 8 62 165 2.3 0 2.6 2.1 04/29/2007 21:00:00 7.5 1.5 11.5 4.6 7.7 1.5 11.5 4.9 7.4 1.3 11.1 4.9 59 11 54 165 2.4 0 2.6 2.3 04/29/2007 21:10:00 7.3 1.2 10.3 4.2 7.5 1.2 10.7 4.2 7.2 1.1 9.9 4.2 57 11 37 165 2.5 0 2.6 2.3 04/29/2007 21:20:00 8.9 1.7 13 4.9 9.1 1.7 13.3 5.3 8.7 1.7 12.6 5.3 60 9 56 165 2.5 0 2.8 2.3 04/29/2007 21:30:00 8 1.7 12.6 3.8 8.2 1.7 12.6 3.8 7.9 1.5 12.6 4.9 57 9 56 165 2.5 0 2.8 2.3 04/29/2007 21:40:00 8.7 1.5 13.3 5.3 8.9 1.5 13.7 5.7 8.5 1.5 13.3 4.2 63 9 50 165 2.6 0 2.8 2.6 04/29/2007 21:50:00 9.4 1.6 14.5 5.3 9.6 1.5 15.3 5.7 9.2 1.5 14.1 6.5 68 10 75 165 2.6 0 2.8 2.6 04/29/2007 22:00:00 9.8 1.6 13.3 6.1 9.9 1.6 13.7 6.5 9.4 1.7 13 6.5 63 9 58 165 2.6 0 2.8 2.6 04/29/2007 22:10:00 9.7 1.8 13.3 4.9 9.9 1.8 13.3 5.3 9.3 1.7 13 4.6 64 9 63 165 2.6 0 2.8 2.6 04/29/2007 22:20:00 10.5 1.4 13.7 7.6 10.7 1.5 14.5 7.6 10.1 1.4 13.7 6.1 68 9 67 165 2.6 0 2.8 2.6 04/29/2007 22:30:00 9.6 1.7 14.5 5.7 9.9 1.7 14.5 6.1 9.6 1.7 14.1 6.1 70 10 69 165 2.6 0 2.8 1.8 04/29/2007 22:40:00 9.2 1.8 14.1 4.6 9.4 1.8 14.5 4.9 9 1.6 13.3 4.6 66 9 65 165 2.7 0 2.8 2.1 04/29/2007 22:50:00 8.9 1.2 12.2 6.1 9.1 1.2 12.6 6.5 8.8 1 11.5 6.1 66 10 53 165 2.8 0 3 2.3 04/29/2007 23:00:00 10.2 1.3 13.7 6.1 10.4 1.3 14.1 6.5 9.7 1.4 13.3 6.1 72 9 77 165 2.7 0 3 2.3 04/29/2007 23:10:00 10.4 1.6 15.3 6.5 10.7 1.7 15.3 6.8 10.2 1.6 14.1 6.1 75 8 73 165 2.7 0 2.8 2.3 04/29/2007 23:20:00 8.9 1.3 12.2 5.3 9.2 1.3 12.6 5.7 8.9 1.3 11.8 6.1 70 9 73 165 2.8 0 3 2.6 04/29/2007 23:30:00 10.1 1.3 13.7 6.1 10.3 1.3 14.1 6.5 9.7 1.3 13.3 6.5 71 8 70 165 2.9 0 3 2.6 04/29/2007 23:40:00 9.5 1.4 13.7 6.5 9.7 1.4 13.7 6.8 9.2 1.4 13.7 6.5 70 9 84 165 2.9 0.1 3.3 2.6 04/29/2007 23:50:00 9.9 1.7 14.1 6.5 10.1 1.7 14.1 6.5 9.7 1.6 13 6.1 74 9 77 165 2.9 0.1 3.3 2.3 04/30/2007 00:00:00 10.9 1.6 14.5 6.1 11.1 1.7 15.3 6.5 10.4 1.5 13.3 5.7 77 8 81 165 2.7 0 3 2.3 04/30/2007 00:10:00 10.3 1.5 14.1 6.8 10.6 1.5 14.5 7.2 9.9 1.4 13.3 6.5 81 8 83 165 2.6 0 3 2.6 04/30/2007 00:20:00 9.7 1.2 13 6.1 10 1.2 13.3 6.1 9.4 1.2 12.6 6.5 81 7 88 165 2.6 0 2.8 2.6 04/30/2007 00:30:00 9.5 1.3 13 6.5 9.8 1.4 13.3 6.8 9.2 1.3 12.2 6.1 80 8 85 165 2.7 0 2.8 2.3 04/30/2007 00:40:00 10.4 1.3 13.3 6.8 10.7 1.3 14.1 7.6 10.1 1.3 13.3 6.5 85 7 86 165 2.7 0 2.8 2.6 04/30/2007 00:50:00 9.8 1.2 12.6 6.5 10 1.2 13 7.2 9.4 1.2 12.6 6.8 85 8 87 165 2.4 0 2.8 2.1 04/30/2007 01:00:00 9.1 1.2 13 6.1 9.3 1.2 13.3 6.5 8.8 1.1 12.6 6.5 79 9 74 165 2.2 0 2.8 2.1 04/30/2007 01:10:00 9.3 1.4 13.3 6.5 9.5 1.4 13.3 6.5 9.2 1.3 13 5.7 75 8 80 165 2.2 0 2.3 1.8 04/30/2007 01:20:00 8.5 1.3 11.8 4.9 8.7 1.2 12.6 5.7 8.4 1.1 11.8 5.7 76 8 79 165 2.1 0 2.3 1.8 04/30/2007 01:30:00 8.7 1.3 12.2 6.1 9 1.3 13 6.1 8.7 1.2 11.8 6.1 77 8 74 165 2 0 2.3 1.8 04/30/2007 01:40:00 8 1.3 11.8 4.9 8.2 1.2 11.8 5.3 7.9 1.2 11.8 4.9 79 7 86 165 2 0 2.3 1.8 04/30/2007 01:50:00 8.1 1.1 10.7 5.7 8.4 1.1 11.5 5.7 8 1 10.7 5.7 76 8 71 165 2.1 0 2.3 1.8 04/30/2007 02:00:00 7 1.2 9.5 4.2 7.3 1.2 10.3 4.6 6.9 1.1 10.3 4.9 76 8 73 165 2 0 2.3 1.8 04/30/2007 02:10:00 7.8 1 10.3 4.9 8 1 10.7 5.7 7.7 1 10.7 5.3 69 8 81 165 2.1 0 2.3 1.8 04/30/2007 02:20:00 8 1.3 11.5 5.3 8.3 1.3 11.8 5.3 8.1 1.2 11.5 4.9 68 8 71 165 2.1 0 2.3 1.8 04/30/2007 02:30:00 8.5 1.5 11.8 5.3 8.8 1.4 12.2 6.1 8.4 1.3 11.8 5.7 72 8 66 165 2 0 2.3 1.8 04/30/2007 02:40:00 7.7 1.1 9.9 4.9 7.9 1 10.7 5.3 7.6 0.9 10.3 5.3 75 7 64 165 1.9 0 2.1 1.8 04/30/2007 02:50:00 6.5 1.1 9.5 4.6 6.8 1 10.3 4.9 6.5 1 9.9 4.2 79 8 87 165 1.9 0 2.1 1.8 04/30/2007 03:00:00 5.2 0.7 6.8 3.4 5.5 0.7 7.6 3.8 5.4 0.7 7.2 3.4 71 8 78 165 1.9 0 2.1 1.8 04/30/2007 03:10:00 5.1 0.8 7.2 3 5.3 0.8 7.6 3 5.3 0.9 8 3.4 66 7 67 165 2 0 2.3 1.8 04/30/2007 03:20:00 5.8 1.4 9.1 3 6.1 1.5 9.1 3 5.9 1.2 9.1 3 68 12 87 165 2.1 0 2.3 1.8 04/30/2007 03:30:00 6.6 0.9 8.8 3.8 6.8 0.9 9.1 4.2 6.6 0.8 8.8 4.6 79 9 92 165 2 0 2.3 1.8 04/30/2007 03:40:00 5.4 1.3 8.4 3.4 5.7 1.4 8.8 3 5.7 1.2 8.8 3.8 73 10 92 165 2 0 2.3 1.8 04/30/2007 03:50:00 6.8 1.1 9.5 4.6 7 1.2 9.9 4.9 6.8 1.1 9.5 4.2 70 9 71 165 2.1 0 2.3 1.8 04/30/2007 04:00:00 6.5 1.1 9.1 3.4 6.8 1.2 9.5 3.8 6.5 1 8.4 4.2 70 9 74 165 2.1 0 2.3 1.8 04/30/2007 04:10:00 6.5 1.2 8.8 4.2 6.8 1.2 9.5 4.2 6.6 1.1 9.5 4.6 68 8 72 165 2.1 0 2.3 1.8 04/30/2007 04:20:00 7.4 0.9 9.5 5.3 7.6 0.9 9.9 5.7 7.5 0.8 9.9 4.9 68 7 58 165 2 0.1 2.3 1.8 04/30/2007 04:30:00 6.9 0.8 8.8 4.2 7.2 0.8 9.1 4.6 7 0.8 8.8 4.9 71 6 70 165 2.1 0 2.3 1.8 04/30/2007 04:40:00 5.2 0.8 7.6 3 5.5 0.8 7.6 3.4 5.3 0.7 7.2 3.8 66 8 71 165 2.3 0 2.6 2.1 04/30/2007 04:50:00 4.8 1 8 3 4.8 1 8 3 4.7 0.9 7.2 2.6 48 10 63 165 2.4 0 2.6 2.3 04/30/2007 05:00:00 5.7 0.9 7.6 3.4 5.8 0.9 8 3.4 5.8 0.9 8 3 40 8 44 165 2.4 0 2.6 2.3 04/30/2007 05:10:00 6.6 0.9 9.5 4.6 6.7 0.8 9.1 3.8 6.6 0.9 8.8 3.8 35 7 36 165 2.7 0.1 3 2.6 04/30/2007 05:20:00 6.3 1.3 9.5 3.4 6.4 1.2 9.5 3.4 6.2 1 9.1 3.4 44 10 40 165 2.9 0 3.3 2.8 04/30/2007 05:30:00 6.4 1.1 10.3 3.8 6.6 1.1 10.3 4.2 6.5 1 9.5 4.2 53 10 51 165 3 0 3.3 2.8 04/30/2007 05:40:00 7.1 1.5 11.1 3.4 7.2 1.4 11.5 3.4 7.2 1.2 10.7 3.8 51 9 47 165 3 0 3.3 2.8 04/30/2007 05:50:00 8.3 1.8 13.3 4.9 8.5 1.9 13.3 4.9 8.1 1.7 13.3 4.9 58 10 58 165 3 0 3.3 2.8 04/30/2007 06:00:00 8.6 1.7 12.2 4.6 8.8 1.7 12.6 4.6 8.5 1.6 12.6 4.6 59 9 58 165 2.9 0 3 2.8 04/30/2007 06:10:00 7.5 1.4 12.2 4.2 7.6 1.4 12.2 4.2 7.5 1.3 11.5 4.6 52 11 66 165 2.7 0 2.8 2.6 04/30/2007 06:20:00 8.6 1.5 13.3 5.3 8.6 1.5 13.3 4.9 8.2 1.3 13 4.9 47 10 56 165 2.8 0 3 2.6 04/30/2007 06:30:00 9.4 1.9 14.1 4.6 9.4 1.9 14.5 4.9 9.1 1.8 14.5 5.7 39 12 42 165 2.9 0 3 2.8 04/30/2007 06:40:00 9.5 1.3 13.3 6.1 9.5 1.4 13.3 6.1 9.4 1.5 13 6.1 40 9 29 165 3 0 3.3 2.8 04/30/2007 06:50:00 10.2 2 16.4 5.7 10.1 2 16.4 5.7 9.8 2 16.1 5.7 35 9 41 165 2.9 0 3 2.8 04/30/2007 07:00:00 11.1 2 15.6 6.1 11.1 2.1 15.6 5.7 10.9 1.9 16.1 6.8 37 9 34 165 2.9 0 3 2.8 04/30/2007 07:10:00 11.5 2 16.1 6.5 11.5 2 16.4 6.1 11.5 2.2 16.1 6.5 36 7 39 165 2.7 0 3 2.6 04/30/2007 07:20:00 10.3 1.5 13.7 6.5 10.2 1.5 14.1 6.1 10 1.6 14.9 6.1 37 8 36 165 2.6 0 2.8 2.3 04/30/2007 07:30:00 9.7 1.5 13.3 6.5 9.6 1.5 13.7 6.5 9.5 1.5 13.7 6.1 34 8 36 165 2.6 0 2.8 2.3 04/30/2007 07:40:00 9.3 1.3 12.6 5.3 9.2 1.3 13 5.7 9.1 1.3 13 4.6 34 9 34 165 2.7 0 2.8 2.6 04/30/2007 07:50:00 8.8 1.3 12.2 4.9 8.9 1.3 12.2 5.3 8.7 1.2 11.8 5.3 36 9 37 165 2.8 0 3 2.6 04/30/2007 08:00:00 9.4 1.7 13.7 4.6 9.3 1.7 13.7 4.2 9.2 1.6 13 4.9 34 9 34 165 2.9 0 3 2.8 04/30/2007 08:10:00 8 1.3 11.1 4.9 8 1.3 11.1 4.6 7.8 1.2 10.7 4.2 33 8 34 165 2.9 0 3 2.8 04/30/2007 08:20:00 7.3 1.3 11.1 4.6 7.4 1.2 10.7 4.6 7.1 1.2 10.7 4.6 37 9 36 165 2.9 0 3 2.8 04/30/2007 08:30:00 8.9 1.4 12.2 5.3 8.9 1.4 12.6 5.7 8.6 1.5 11.8 4.9 36 7 36 165 3 0 3.3 2.6 04/30/2007 08:40:00 11 1.5 15.6 6.5 11 1.5 15.6 6.5 10.5 1.6 15.3 5.7 36 8 26 165 3.2 0 3.3 2.6 04/30/2007 08:50:00 10.3 1.6 13.7 6.5 10.3 1.6 13.7 6.5 10.1 1.7 14.5 6.1 35 8 26 165 3.2 0 3.5 2.8 04/30/2007 09:00:00 10.3 1.9 15.3 6.1 10.1 2 15.3 6.5 10.1 1.7 15.6 6.5 30 8 36 165 3.2 0 3.5 2.8 04/30/2007 09:10:00 12.1 1.6 16.1 8.4 11.8 1.7 15.6 6.5 11.7 1.7 16.4 6.8 26 9 27 165 3.1 0.1 3.3 2.8 04/30/2007 09:20:00 11.4 1.6 16.1 7.6 11.1 1.7 16.4 6.8 10.8 1.5 15.6 8 27 8 30 165 2.9 0 3.3 2.8 04/30/2007 09:30:00 10.3 1.9 14.5 5.3 10.1 2 14.5 4.9 9.8 1.7 14.5 5.7 29 9 15 165 2.9 0 3.3 2.8 04/30/2007 09:40:00 11.4 1.7 15.3 7.2 11.2 1.9 15.3 7.2 11.1 1.9 15.6 7.6 29 8 29 165 3 0 3.3 2.6 04/30/2007 09:50:00 11.4 2 16.8 7.2 11.2 2.1 16.1 6.8 11.1 1.8 16.4 7.2 29 9 33 165 3 0 3.3 2.8 04/30/2007 10:00:00 12.1 1.5 15.6 7.6 11.9 1.7 15.6 6.8 11.8 1.4 15.3 7.6 26 9 14 165 2.7 0 3.3 2.6 04/30/2007 10:10:00 11.4 1.7 16.4 6.5 11.1 1.9 16.8 5.3 11 1.7 15.6 6.8 25 8 35 165 2.6 0 2.8 2.6 04/30/2007 10:20:00 11 1.4 14.1 7.2 10.3 1.5 13.3 5.3 10.8 1.4 13.7 6.5 20 8 18 165 2.7 0 2.8 2.6 04/30/2007 10:30:00 10.6 1.5 14.1 6.8 10 1.7 14.1 5.3 10.3 1.6 14.5 6.5 18 7 16 165 2.7 0 2.8 2.6 04/30/2007 10:40:00 8.3 1 11.1 5.7 6.4 1.1 9.1 3.8 8.4 1 10.7 5.7 7 7 13 165 2.7 0 2.8 2.6 04/30/2007 10:50:00 7.7 1.1 10.3 5.3 6.5 1.3 10.3 3.4 7.7 1.1 11.1 5.3 12 7 19 165 2.7 0 3 2.6 04/30/2007 11:00:00 6.9 1.1 9.9 4.2 6.3 1.3 9.9 3 6.8 1 9.9 4.6 17 10 16 165 2.9 0 3 2.8 04/30/2007 11:10:00 6.2 1.1 9.9 3.4 6.3 1.1 9.9 3.4 6.3 0.9 9.5 4.2 30 10 19 165 3 0 3.3 2.8 04/30/2007 11:20:00 4.9 1.1 9.5 3 5 1.2 9.9 3 5 1.1 9.5 2.3 44 12 59 165 3.2 0 3.5 3 04/30/2007 11:30:00 7.4 1.5 10.7 4.9 7.5 1.4 10.7 4.9 7.4 1.4 10.7 4.6 39 9 44 165 3 0.1 3.3 2.8 04/30/2007 11:40:00 8.5 1.3 11.8 5.3 8.2 1.4 12.2 5.3 8.3 1.3 11.8 5.7 25 10 35 165 2.9 0 3 2.8 04/30/2007 11:50:00 10.3 1.3 13 7.2 9.9 1.5 13 5.3 10.1 1.3 13 6.8 22 8 16 165 2.9 0 3 2.8 04/30/2007 12:00:00 11 1.4 14.5 7.6 10.5 1.6 14.5 5.7 10.6 1.4 13.7 7.2 19 7 21 165 3 0 3.3 2.8 04/30/2007 12:10:00 9.7 1.1 12.6 6.8 9.5 1.2 12.6 6.1 9.5 1.1 12.2 6.8 25 8 31 165 2.9 0 3 2.6 04/30/2007 12:20:00 8.6 1.4 12.6 5.3 8.3 1.5 13 4.6 8.3 1.5 12.2 5.7 23 9 33 165 2.7 0 3 2.6 04/30/2007 12:30:00 9.1 1.2 11.8 6.1 8.7 1.3 11.5 4.9 9 1.2 11.8 6.1 19 8 16 165 2.9 0 3 2.8 04/30/2007 12:40:00 8.4 1.5 12.6 4.6 8 1.5 12.6 3.8 8.3 1.3 12.2 5.3 20 8 23 165 3 0 3.3 2.8 04/30/2007 12:50:00 8.8 1.5 11.5 4.6 8.5 1.6 11.5 4.2 8.5 1.6 11.8 4.6 20 8 20 165 3 0 3.3 2.6 04/30/2007 13:00:00 8.6 1.3 11.8 4.9 8 1.5 11.5 4.6 8.2 1.3 11.5 4.9 18 8 18 165 3.1 0 3.3 2.6 04/30/2007 13:10:00 9.4 1.3 12.6 5.3 8.2 1.5 11.8 3.8 9.2 1.2 12.2 5.7 13 7 12 165 3.3 0 3.5 2.8 04/30/2007 13:20:00 9.5 1.1 12.2 5.7 7.6 1.3 11.8 4.6 9.5 1.1 12.6 6.1 10 7 22 165 3.5 0.1 3.5 3 04/30/2007 13:30:00 10.1 0.9 12.2 6.8 8.4 1.3 11.1 4.9 10 1.1 13 6.5 13 6 12 165 3.5 0.1 3.8 3 04/30/2007 13:40:00 9.4 0.8 11.5 6.8 8.1 1.2 10.7 4.9 9.2 0.8 11.1 7.2 13 5 19 165 3.2 0.1 3.5 2.6 04/30/2007 13:50:00 8.1 1 11.1 5.7 5.8 1.3 8.8 3 7.9 0.9 10.3 5.3 6 7 5 165 3.1 0 3.5 2.8 04/30/2007 14:00:00 7.3 1.2 9.9 4.6 5.3 1.2 8.4 2.6 7.4 1.1 10.3 4.9 2 8 8 165 3.3 0 3.5 2.8 04/30/2007 14:10:00 8.6 1 11.5 6.1 6.4 1.3 10.3 3.4 8.5 1.1 11.1 6.5 6 8 12 165 3.5 0.1 3.8 2.8 04/30/2007 14:20:00 8.8 1 11.5 6.8 7 1.3 10.3 4.2 8.5 1 11.8 6.5 7 7 14 165 3.6 0 3.8 3.3 04/30/2007 14:30:00 7.7 1 9.9 5.3 7 1.2 9.9 4.2 7.6 0.9 10.3 5.7 13 9 18 165 3.6 0 3.8 3.5 04/30/2007 14:40:00 7.4 1 9.9 4.9 7.1 1.1 9.5 4.2 7.1 1 9.9 4.6 17 8 4 165 3.6 0 3.8 3.5 04/30/2007 14:50:00 7.8 1 9.9 4.6 7.5 1 9.9 3.8 7.8 0.9 9.9 4.9 16 8 13 165 3.8 0 4 3.5 04/30/2007 15:00:00 7.5 1 9.5 4.9 7.3 1.1 9.5 4.2 7.4 0.8 9.1 4.9 17 6 18 165 3.8 0 4 3.5 04/30/2007 15:10:00 6.9 1 9.1 3.8 6.8 0.9 8.8 4.2 6.7 0.9 9.1 4.2 17 6 21 165 3.7 0 4 3.3 04/30/2007 15:20:00 6.1 0.7 8.4 4.2 6.2 0.7 8.4 3.8 6 0.8 8.8 3.8 31 9 26 165 3.2 0.1 3.8 3 04/30/2007 15:30:00 7.2 1.4 10.3 3.8 7 1.5 10.3 3.4 7.1 1.2 9.9 3.8 19 7 20 165 3.1 0 3.3 2.8 04/30/2007 15:40:00 7.6 1.1 9.5 4.2 7.2 1.2 9.5 3.8 7.6 1.1 10.7 4.9 18 8 13 165 3.2 0 3.5 2.8 04/30/2007 15:50:00 7.2 0.8 9.5 4.6 7 0.8 9.5 4.6 6.9 0.8 8.8 4.9 18 6 16 165 3.2 0 3.5 3 04/30/2007 16:00:00 7 0.8 8.4 4.6 6.9 0.8 8.4 4.6 6.9 0.7 8.8 4.9 20 5 26 165 3 0 3.3 2.8 04/30/2007 16:10:00 6.2 0.8 8 4.2 5.8 1 7.6 3 6.3 0.8 8 4.2 15 6 16 165 3 0 3.3 2.8 04/30/2007 16:20:00 5.3 0.6 7.2 3.8 5.1 0.7 6.8 3 5.5 0.6 7.2 3.4 14 6 15 165 3 0 3.3 2.8 04/30/2007 16:30:00 4.4 0.6 5.7 2.6 4.4 0.7 6.1 2.6 4.7 0.6 6.1 3.4 22 7 23 165 3 0 3.3 2.8 04/30/2007 16:40:00 3.6 0.6 4.9 2.3 3.5 0.7 4.9 1.9 3.8 0.6 5.3 2.6 23 8 14 165 3 0 3.3 2.8 04/30/2007 16:50:00 3.1 0.7 4.6 1.5 3 0.6 4.2 1.5 3.2 0.7 4.6 1.5 41 18 12 165 3 0 3.3 2.6 04/30/2007 17:00:00 2.7 0.4 3.8 1.5 2.8 0.4 3.8 1.9 3 0.4 3.8 2.3 92 12 87 165 2.9 0.1 3.3 2.3 04/30/2007 17:10:00 2.3 0.4 3.4 1.1 2.3 0.5 3.4 1.1 2.5 0.4 3.4 1.1 106 8 105 165 2.9 0 3 2.3 04/30/2007 17:20:00 2.5 0.4 3.8 1.5 2.7 0.4 3.8 1.5 2.8 0.4 3.8 1.9 115 6 109 165 2.9 0 3 2.6 04/30/2007 17:30:00 1 0.5 2.3 0.4 1.1 0.6 2.6 0.4 1.6 0.5 2.6 0.4 94 11 101 165 3 0.1 3.3 2.3 04/30/2007 17:40:00 0.9 0.4 1.9 0.4 1 0.5 1.9 0.4 1.5 0.4 2.6 0.4 98 9 96 165 3 0.2 3.3 2.3 04/30/2007 17:50:00 0.4 0.1 0.7 0.4 0.4 0.1 1.1 0.4 0.8 0.3 1.9 0.4 99 9 105 165 2.9 0.2 3.3 2.3 04/30/2007 18:00:00 0.4 0.1 1.1 0.4 0.4 0.2 1.1 0.4 0.8 0.4 1.9 0.4 108 13 118 165 3.1 0.1 3.5 2.6 04/30/2007 18:10:00 0.5 0.3 1.5 0.4 0.5 0.2 1.5 0.4 1 0.5 2.3 0.4 36 29 15 165 3.3 0.1 3.5 2.8 04/30/2007 18:20:00 0.4 0.2 1.5 0.4 0.4 0.2 1.5 0.4 0.7 0.4 1.9 0.4 71 12 59 165 3.4 0.2 3.5 2.8 04/30/2007 18:30:00 0.4 0 0.4 0.4 0.4 0 0.7 0.4 0.5 0.3 1.5 0.4 111 17 165 165 3.2 0 3.5 2.8 04/30/2007 18:40:00 0.6 0.5 1.9 0.4 0.8 0.6 2.3 0.4 1.2 0.7 2.6 0.4 131 11 142 165 3.1 0.2 3.5 2.6 04/30/2007 18:50:00 1.6 0.4 2.6 0.4 1.7 0.4 2.6 0.7 2.2 0.4 3 1.5 133 8 133 165 2.9 0.2 3.3 2.3 04/30/2007 19:00:00 0.7 0.4 1.5 0.4 0.6 0.4 1.9 0.4 1.2 0.5 2.3 0.4 133 0 134 165 2.7 0 3 2.6 04/30/2007 19:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0.1 1.1 0.4 133 0 165 165 2.7 0 2.8 2.6 04/30/2007 19:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 134 0 165 165 2.8 0 3 2.6 04/30/2007 19:30:00 0.4 0.1 1.1 0.4 0.4 0 0.4 0.4 0.4 0.1 1.1 0.4 121 32 31 165 2.9 0 3 2.8 04/30/2007 19:40:00 0.6 0.3 1.1 0.4 0.4 0 0.4 0.4 0.8 0.3 1.5 0.4 23 15 31 165 2.9 0 3 2.8 04/30/2007 19:50:00 1.1 0.2 1.5 0.7 0.5 0.2 1.1 0.4 1.5 0.3 1.9 0.7 354 0 354 165 2.8 0 3 2.6 04/30/2007 20:00:00 0.8 0.2 1.5 0.4 0.5 0.2 1.1 0.4 1.4 0.2 1.9 1.1 352 3 354 165 2.6 0 2.8 2.6 04/30/2007 20:10:00 0.8 0.2 1.5 0.4 0.6 0.3 1.1 0.4 1.4 0.2 1.9 1.1 341 5 336 165 2.5 0 2.8 2.3 04/30/2007 20:20:00 0.4 0.1 1.1 0.4 0.4 0 0.7 0.4 0.9 0.3 1.5 0.4 336 0 336 165 2.4 0 2.6 2.3 04/30/2007 20:30:00 0.4 0 0.7 0.4 0.4 0 0.4 0.4 0.9 0.2 1.5 0.4 336 0 336 165 2.4 0 2.6 2.3 04/30/2007 20:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0.1 0.7 0.4 336 0 165 165 2.3 0 2.6 2.1 04/30/2007 20:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 336 0 165 165 2.2 0 2.3 2.1 04/30/2007 21:00:00 0.5 0.3 1.5 0.4 0.5 0.4 1.9 0.4 0.8 0.7 2.3 0.4 15 90 164 165 2.1 0 2.3 1.8 04/30/2007 21:10:00 0.7 0.4 1.9 0.4 0.8 0.5 2.3 0.4 1.3 0.4 2.3 0.4 176 13 171 165 2.3 0 2.6 1.8 04/30/2007 21:20:00 0.6 0.4 1.5 0.4 1 0.4 1.9 0.4 1.6 0.3 2.6 0.7 164 4 164 165 2.4 0 2.6 2.3 04/30/2007 21:30:00 0.8 0.5 1.9 0.4 1 0.6 2.3 0.4 1.5 0.5 2.6 0.4 150 13 175 165 2.3 0 2.6 2.3 04/30/2007 21:40:00 0.4 0 0.7 0.4 0.8 0.4 1.5 0.4 1.4 0.4 2.3 0.7 160 4 164 165 2.3 0 2.6 2.1 04/30/2007 21:50:00 0.9 0.5 1.9 0.4 1.3 0.5 2.3 0.4 1.8 0.4 2.6 0.7 156 3 153 165 2.4 0 2.6 2.1 04/30/2007 22:00:00 0.4 0.1 1.1 0.4 0.5 0.3 1.1 0.4 0.8 0.4 1.9 0.4 167 2 164 165 2.3 0 2.6 2.1 04/30/2007 22:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.5 0.2 1.1 0.4 163 0 165 165 2.3 0 2.6 2.1 04/30/2007 22:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0.1 1.1 0.4 148 38 165 165 2.3 0 2.3 2.1 04/30/2007 22:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.7 0.2 1.1 0.4 47 3 165 165 2.1 0 2.3 2.1 04/30/2007 22:40:00 0.4 0 0.7 0.4 0.4 0 0.4 0.4 0.7 0.2 1.1 0.4 25 0 25 165 2.1 0 2.3 1.8 04/30/2007 22:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0.1 0.7 0.4 25 0 165 165 2 0 2.3 1.8 04/30/2007 23:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 25 0 165 165 1.9 0 2.3 1.8 04/30/2007 23:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 25 0 165 165 2 0 2.3 1.8 04/30/2007 23:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0.1 0.7 0.4 62 41 165 165 2 0 2.3 1.8 04/30/2007 23:30:00 0.4 0 0.7 0.4 0.4 0 0.4 0.4 1 0.3 1.5 0.4 132 0 132 165 2 0 2.3 1.8 04/30/2007 23:40:00 0.4 0 0.4 0.4 0.4 0 0.7 0.4 0.8 0.2 1.1 0.4 141 1 165 165 2.1 0 2.3 1.8 04/30/2007 23:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0.1 0.7 0.4 142 0 165 165 2.1 0 2.3 2.1 05/01/2007 00:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.6 0.3 1.1 0.4 142 1 165 165 2.1 0 2.3 1.8 05/01/2007 00:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.7 0.2 1.1 0.4 177 13 165 165 2.1 0 2.3 1.8 05/01/2007 00:20:00 0.4 0 0.4 0.4 0.4 0.1 0.7 0.4 0.7 0.3 1.5 0.4 179 10 165 165 2.1 0 2.3 1.8 05/01/2007 00:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 1 0.2 1.5 0.7 191 0 165 165 2.1 0 2.3 1.8 05/01/2007 00:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.9 0.2 1.5 0.4 191 0 165 165 2.1 0 2.3 1.8 05/01/2007 00:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.6 0.3 1.1 0.4 190 0 165 165 2.1 0 2.3 1.8 05/01/2007 01:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 190 0 165 165 2.1 0 2.3 1.8 05/01/2007 01:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 190 0 165 165 2.1 0 2.3 1.8 05/01/2007 01:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0.2 1.1 0.4 184 6 165 165 2 0 2.3 1.8 05/01/2007 01:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.8 0.2 1.1 0.4 177 0 165 165 2.1 0 2.3 1.8 05/01/2007 01:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.5 0.2 1.1 0.4 177 0 165 165 2 0 2.3 1.8 05/01/2007 01:50:00 0.4 0 0.4 0.4 0.4 0 0.7 0.4 0.4 0.2 1.1 0.4 178 6 165 165 1.9 0 2.1 1.8 05/01/2007 02:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 1 0.2 1.5 0.7 201 0 165 165 1.9 0 1.8 1.6 05/01/2007 02:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.7 0.3 1.1 0.4 192 5 165 165 1.9 0 1.8 1.8 05/01/2007 02:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 189 0 165 165 1.9 0 1.8 1.8 05/01/2007 02:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 189 0 165 165 1.9 0 1.8 1.6 05/01/2007 02:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 189 0 165 165 1.9 0 2.1 1.6 05/01/2007 02:50:00 0.4 0.1 1.1 0.4 0.4 0.2 1.1 0.4 1 0.5 1.9 0.4 170 20 188 165 1.8 0 1.8 1.6 05/01/2007 03:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.6 0.3 1.1 0.4 148 0 165 165 1.8 0 1.8 1.6 05/01/2007 03:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.6 0.2 1.1 0.4 148 0 165 165 1.8 0 1.8 1.6 05/01/2007 03:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 148 0 165 165 1.8 0 1.8 1.6 05/01/2007 03:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 146 1 165 165 1.5 0 1.8 1.4 05/01/2007 03:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 143 0 165 165 1.5 0 1.6 1.4 05/01/2007 03:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 141 1 165 165 1.5 0 1.6 1.4 05/01/2007 04:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 140 0 165 165 1.5 0 1.6 1.4 05/01/2007 04:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 139 0 165 165 1.5 0 1.6 1.4 05/01/2007 04:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 138 0 165 165 1.5 0 1.6 1.4 05/01/2007 04:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 135 2 165 165 1.5 0 1.6 1.4 05/01/2007 04:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 123 3 165 165 1.5 0 1.6 1.4 05/01/2007 04:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 120 0 165 165 1.5 0 1.6 1.4 05/01/2007 05:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 120 0 165 165 1.5 0 1.6 1.4 05/01/2007 05:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 120 0 165 165 1.5 0 1.6 1.4 05/01/2007 05:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 120 0 165 165 1.5 0 1.6 1.4 05/01/2007 05:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 120 0 165 165 1.5 0 1.6 1.4 05/01/2007 05:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 120 0 165 165 1.7 0 1.8 1.4 05/01/2007 05:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 120 0 165 165 1.8 0 2.1 1.6 05/01/2007 06:00:00 0.6 0.3 1.5 0.4 0.4 0 0.4 0.4 1.2 0.6 2.3 0.4 117 3 112 165 1.9 0 2.1 1.8 05/01/2007 06:10:00 0.8 0.3 1.5 0.4 0.4 0 0.4 0.4 1.6 0.2 2.3 1.1 99 6 100 165 1.8 0 1.8 1.6 05/01/2007 06:20:00 0.8 0.5 1.9 0.4 0.8 0.6 2.3 0.4 1.6 0.4 2.3 0.7 71 17 50 165 1.8 0 1.8 1.6 05/01/2007 06:30:00 2 0.3 2.6 1.1 1.9 0.2 2.6 1.5 2.4 0.3 3 1.9 38 4 32 165 1.9 0 2.1 1.8 05/01/2007 06:40:00 2.3 0.3 3 1.5 2.2 0.3 2.6 1.5 2.9 0.2 3.4 2.3 30 1 31 165 1.8 0 1.8 1.6 05/01/2007 06:50:00 2 0.4 2.6 1.5 2 0.4 2.6 1.1 2.6 0.4 3.8 1.9 29 1 32 165 1.8 0 1.8 1.6 05/01/2007 07:00:00 2.5 0.3 3 1.9 2.4 0.2 3 1.9 3 0.3 3.8 2.6 31 2 32 165 1.8 0 1.8 1.6 05/01/2007 07:10:00 2.9 0.2 3.4 2.6 2.8 0.2 3.4 2.3 3.4 0.2 4.2 3 26 1 26 165 1.9 0 2.1 1.6 05/01/2007 07:20:00 2.6 0.2 3 2.3 2.8 0.2 3 2.3 3.2 0.2 3.4 2.6 30 3 28 165 2 0 2.3 1.8 05/01/2007 07:30:00 2.9 0.2 3.4 2.3 2.9 0.2 3.4 2.3 3.3 0.2 3.8 2.6 25 4 29 165 2 0 2.3 1.8 05/01/2007 07:40:00 2.5 0.3 3 1.5 1.8 0.5 3 0.7 3 0.2 3.4 2.3 14 3 23 165 2.3 0 2.6 1.8 05/01/2007 07:50:00 2.1 0.2 2.6 1.5 1.6 0.3 2.3 0.7 2.6 0.2 3 2.3 13 2 17 165 2.3 0 2.6 2.3 05/01/2007 08:00:00 2.7 0.3 3.4 1.9 2.6 0.4 3.4 1.5 2.9 0.3 3.8 2.3 18 3 19 165 2.3 0 2.6 2.3 05/01/2007 08:10:00 2 0.7 3 0.7 1.9 0.8 3 0.4 2.3 0.6 3.4 0.7 9 17 21 165 2.6 0 3 2.3 05/01/2007 08:20:00 1.7 0.4 2.6 0.4 0.7 0.3 1.9 0.4 1.9 0.4 2.6 1.1 3 4 3 165 3.2 0.2 3.8 2.3 05/01/2007 08:30:00 1 0.4 1.9 0.4 0.8 0.4 1.9 0.4 1.1 0.4 1.9 0.4 345 6 353 165 3.8 0.1 4.3 3 05/01/2007 08:40:00 1 0.5 2.3 0.4 0.8 0.4 1.9 0.4 1 0.4 2.3 0.4 340 9 341 165 4.1 0.2 4.5 3.5 05/01/2007 08:50:00 0.8 0.4 2.3 0.4 0.5 0.3 2.3 0.4 0.9 0.4 2.3 0.4 357 17 17 165 4.4 0.1 4.8 3.8 05/01/2007 09:00:00 1.8 0.7 3 0.4 1.7 0.7 3 0.4 1.6 0.7 3 0.4 346 22 26 165 4.4 0.3 5 3.5 05/01/2007 09:10:00 3.1 0.7 4.9 1.5 2.8 0.7 4.6 1.5 3.1 0.6 4.9 1.1 344 8 349 165 4.4 0.3 5.2 3.8 05/01/2007 09:20:00 3.6 0.4 4.9 2.6 3.4 0.5 4.6 1.5 3.6 0.5 4.9 2.3 334 9 328 165 3.5 0.3 4 2.6 05/01/2007 09:30:00 3.6 0.4 4.9 2.3 3.3 0.4 4.6 1.9 3.7 0.4 4.6 2.6 327 6 323 165 3.2 0.1 3.5 2.6 05/01/2007 09:40:00 4.6 0.6 6.1 3.4 3.9 0.9 6.1 1.5 4.8 0.8 6.8 3 346 11 353 165 3.1 0.1 3.5 2.3 05/01/2007 09:50:00 4.6 0.5 6.5 3.8 4.5 0.6 6.1 2.3 4.9 0.6 6.5 3.4 343 8 339 165 3.6 0.4 4.5 3 05/01/2007 10:00:00 5.3 0.9 7.2 3.4 5.4 1 8 2.6 5.4 0.8 7.2 3.4 342 7 350 165 4.3 0.2 4.8 3.5 05/01/2007 10:10:00 6.2 1 8.8 4.6 6.1 1.1 8.8 2.6 6.3 1 9.5 4.6 339 12 344 165 4.3 0.2 4.8 3.5 05/01/2007 10:20:00 5.2 0.9 8 2.3 5.2 1 8 2.6 4.9 0.9 7.6 2.6 324 23 347 165 4.4 0.2 4.8 3.8 05/01/2007 10:30:00 4 0.9 6.1 0.7 3.8 0.9 5.7 0.4 3.6 0.8 6.5 1.1 307 17 310 165 4.4 0.3 5.2 3.8 05/01/2007 10:40:00 5.3 1.6 9.5 1.9 4.9 1.5 9.1 1.1 5 1.7 8.8 1.9 322 17 309 165 4.8 0.6 5.7 3.8 05/01/2007 10:50:00 6.9 1.2 10.7 4.2 6.6 1.3 11.1 3 6.9 1.2 10.3 4.2 340 10 348 165 4.5 0.2 5.2 4 05/01/2007 11:00:00 4.9 1.2 9.9 2.3 4.8 1.1 9.5 2.3 4.7 1.2 9.9 2.3 326 15 349 165 4.4 0.1 4.8 4.3 05/01/2007 11:10:00 7.7 1.1 10.3 4.6 7.6 1.2 10.7 4.2 7.5 1.1 9.9 4.2 339 13 346 165 4.9 0.2 5.5 4.5 05/01/2007 11:20:00 7.5 1.2 9.9 4.9 7.3 1.2 9.9 4.2 7.4 1.1 10.3 4.6 342 8 337 165 4.6 0.3 5.2 4.3 05/01/2007 11:30:00 7.2 1.3 10.3 3.4 7.2 1.3 10.3 3.4 7.1 1.2 10.3 4.6 336 9 342 165 4.3 0 4.5 4.3 05/01/2007 11:40:00 6.8 1.3 11.1 4.2 6.4 1.2 9.1 3.8 6.9 1.2 10.3 3.8 342 12 4 165 4.4 0 4.5 4.3 05/01/2007 11:50:00 5.4 1.2 8.8 3.4 5.4 1.2 9.1 3.4 5.5 1.1 8.8 3 332 11 344 165 3.9 0.1 4.5 3.5 05/01/2007 12:00:00 5.7 0.8 7.6 3.4 5.7 0.8 7.6 3.4 5.5 0.9 7.6 3 315 9 328 165 3.7 0 4 3.5 05/01/2007 12:10:00 5.8 0.9 8 3.4 5.8 0.8 7.6 3.8 4.9 0.8 7.2 3 301 11 316 165 3.9 0.2 4.5 3.5 05/01/2007 12:20:00 8.6 1.7 12.6 4.9 8.4 1.7 13 4.9 8.6 1.6 11.8 5.7 338 12 346 165 4.4 0.1 4.8 4 05/01/2007 12:30:00 8.4 1.2 12.2 5.3 8.1 1.1 11.8 5.3 8 1.3 12.2 5.7 327 16 353 165 4.1 0.1 4.5 3.8 05/01/2007 12:40:00 8.8 1.7 12.6 4.6 8.5 1.7 12.2 4.6 8.5 1.7 13.3 4.6 336 15 335 165 4.4 0.2 4.8 3.8 05/01/2007 12:50:00 10.3 1.7 14.5 6.5 10.2 1.6 14.9 6.5 10.1 1.7 14.9 5.3 335 9 355 165 3.4 0.2 4.3 2.8 05/01/2007 13:00:00 7.8 1.5 11.1 4.6 7.7 1.4 11.5 4.2 7.4 1.6 11.1 3.8 322 16 334 165 3.2 0 3.5 2.8 05/01/2007 13:10:00 8.9 1.3 11.8 4.9 8.8 1.3 11.5 5.7 7.1 1.3 11.5 3.8 300 8 294 165 3.1 0.1 3.5 2.8 05/01/2007 13:20:00 9.1 1 11.8 5.7 9 1 11.5 5.7 7.9 1.1 10.3 4.6 311 13 299 165 3.1 0 3.3 2.8 05/01/2007 13:30:00 8.7 1 11.8 6.5 8.6 1 12.2 6.1 8.6 1 11.8 5.7 325 11 313 165 3.2 0 3.5 3 05/01/2007 13:40:00 8.9 1.2 12.6 6.1 8.8 1.2 12.2 6.1 8.9 1.1 11.8 5.7 334 11 340 165 3.2 0 3.5 3 05/01/2007 13:50:00 7.8 1.2 11.5 4.6 7.6 1.3 11.5 4.6 7.9 1.2 11.1 4.6 336 15 351 165 3.2 0 3.5 3 05/01/2007 14:00:00 8.3 1.3 11.1 5.3 8.3 1.3 11.5 4.9 8.6 1.1 11.1 5.7 337 10 347 165 3.2 0 3.5 2.8 05/01/2007 14:10:00 8.1 1.3 11.8 5.3 8 1.3 11.8 4.9 8.1 1.3 11.8 5.3 338 11 347 165 2.9 0.1 3.3 2.6 05/01/2007 14:20:00 6.5 1 9.5 4.6 6.5 1 9.5 4.9 6.6 0.8 8.8 4.9 334 11 345 165 2.8 0.2 3 2.3 05/01/2007 14:30:00 6 0.8 8.4 3.8 6.1 0.8 8.4 3.8 6 0.8 8.4 3.8 323 11 325 165 2.9 0.1 3.3 2.6 05/01/2007 14:40:00 7.1 0.9 9.1 4.9 7.2 0.9 9.1 4.2 7.1 0.9 9.1 4.2 324 9 318 165 3.2 0.1 3.5 2.3 05/01/2007 14:50:00 7.3 0.9 9.5 5.3 7.4 0.8 9.5 5.3 7.4 0.8 9.9 5.7 325 8 324 165 3.1 0.1 3.5 2.8 05/01/2007 15:00:00 7.9 1.2 10.3 4.9 7.9 1.2 10.3 4.6 7.4 1 9.9 4.9 312 10 296 165 2.9 0.1 3.3 2.6 05/01/2007 15:10:00 8.1 1.2 10.7 5.3 8.1 1.1 11.1 5.7 7.8 1.2 10.7 4.9 317 10 316 165 2.7 0.2 3 2.3 05/01/2007 15:20:00 7.3 1.1 9.9 3.8 7.4 1 9.9 3.8 7.2 1.1 10.3 4.2 318 10 320 165 2.7 0 2.8 2.1 05/01/2007 15:30:00 6.7 0.8 8.8 4.6 6.8 0.7 8.8 4.9 6.6 0.8 8.8 4.6 313 7 313 165 2.6 0 2.8 2.3 05/01/2007 15:40:00 6.8 1 9.5 4.6 6.9 0.9 9.5 4.6 6.6 0.9 8.8 4.6 316 9 302 165 2.6 0 2.8 2.3 05/01/2007 15:50:00 6.4 0.8 8.4 4.6 6.5 0.7 8.8 4.6 5.8 0.8 8.4 3 310 10 297 165 2.5 0 2.8 2.3 05/01/2007 16:00:00 6.1 0.6 8.4 4.6 6.3 0.6 8 4.6 6.1 0.7 8 4.2 320 10 293 165 2.5 0.1 2.8 1.8 05/01/2007 16:10:00 6.5 0.6 8.4 4.9 6.8 0.6 8.4 4.9 6.7 0.8 9.1 4.6 317 7 312 165 2.5 0.1 2.8 1.8 05/01/2007 16:20:00 5 0.6 6.8 3.4 5.3 0.6 6.8 3.8 5.3 0.7 6.8 3.8 327 9 319 165 2.4 0 2.6 1.8 05/01/2007 16:30:00 5.1 0.6 6.5 3.8 5.4 0.6 6.8 3.8 5.5 0.6 6.8 3.8 332 9 326 165 2.4 0.1 2.8 1.8 05/01/2007 16:40:00 3.9 0.7 5.7 2.6 4.1 0.8 6.1 2.6 4 0.8 6.1 1.9 327 13 314 165 2.5 0.1 2.8 1.8 05/01/2007 16:50:00 3.3 0.4 4.2 1.9 3.2 0.5 4.2 1.9 3 0.5 4.2 1.5 318 10 325 165 2.5 0 2.8 2.3 05/01/2007 17:00:00 3.7 0.4 4.9 2.6 3.9 0.4 4.9 2.6 3.4 0.5 5.3 2.3 310 9 291 165 2.4 0 2.8 2.3 05/01/2007 17:10:00 4 0.5 5.3 2.6 4.2 0.6 5.3 2.6 3.7 0.6 5.7 2.3 306 10 295 165 2.4 0 2.6 1.8 05/01/2007 17:20:00 4.2 0.4 4.9 3 4.5 0.3 5.3 3.8 3.8 0.5 4.9 2.6 304 7 293 165 2.4 0.2 2.8 1.8 05/01/2007 17:30:00 4.2 0.5 5.7 3 4.6 0.5 6.1 3.4 4.3 0.5 5.7 3 322 12 340 165 2.5 0 2.8 2.1 05/01/2007 17:40:00 3.8 0.5 5.3 2.3 3.9 0.6 6.1 1.9 4.1 0.5 5.7 2.6 331 12 345 165 2.7 0.2 3 2.1 05/01/2007 17:50:00 3.6 0.6 5.3 2.3 3.3 0.7 5.7 1.5 3.7 0.6 5.7 1.9 351 17 354 165 2.9 0.1 3.3 2.6 05/01/2007 18:00:00 4.7 1 7.2 2.3 4.1 1.3 7.2 1.1 5 1 7.6 2.6 9 8 18 165 3.3 0.1 3.5 2.8 05/01/2007 18:10:00 4.7 0.6 6.5 3.4 3.9 1 6.1 1.9 5.1 0.7 6.8 3.8 8 7 10 165 3.5 0.1 3.8 3 05/01/2007 18:20:00 5.3 0.7 7.2 3.8 4.7 1 7.2 1.9 5.6 0.7 7.6 3.8 11 6 9 165 3.6 0.1 3.8 3 05/01/2007 18:30:00 4.8 0.6 6.5 3.4 4.7 0.7 6.8 2.3 5.2 0.8 6.8 3 15 6 22 165 3.6 0.1 3.8 3 05/01/2007 18:40:00 4.8 0.7 7.2 3 4.7 0.8 7.2 1.9 5 0.7 6.8 3 16 7 7 165 3.6 0 3.8 3 05/01/2007 18:50:00 5.3 0.6 6.8 3.8 4.9 0.7 6.8 3 5.5 0.5 7.2 4.6 13 6 31 165 3.6 0 3.8 3.3 05/01/2007 19:00:00 4.5 0.5 5.7 3.4 4.4 0.6 5.7 3 4.7 0.6 6.5 3.4 17 6 16 165 3.5 0 3.8 3.3 05/01/2007 19:10:00 5.4 0.7 7.2 3.8 5.2 0.7 7.6 3 5.7 0.7 7.2 3.8 16 8 14 165 3.5 0 3.8 3.3 05/01/2007 19:20:00 6.8 1.1 9.9 4.2 5.9 1 9.1 3.4 7.1 1 9.9 5.3 10 5 8 165 3.5 0.1 3.8 3 05/01/2007 19:30:00 6.9 1.1 10.7 4.6 6 1.2 9.1 2.3 7.1 1 10.3 4.9 11 7 12 165 3.5 0.1 3.5 3 05/01/2007 19:40:00 6.5 0.7 8.4 4.9 6.2 0.8 8 3.4 6.7 0.7 8.4 4.6 15 6 14 165 3.5 0.1 3.5 2.8 05/01/2007 19:50:00 5.6 0.9 8.4 3.8 5.5 1 8.4 2.6 5.8 0.9 8.4 4.2 19 7 22 165 3.5 0.1 3.5 2.8 05/01/2007 20:00:00 5.8 0.7 7.6 4.2 5.8 0.7 7.6 2.6 6.1 0.6 7.2 4.2 18 7 22 165 3.5 0.2 3.8 2.8 05/01/2007 20:10:00 5.1 0.8 6.8 2.6 5.1 0.8 7.2 2.6 5.2 0.8 7.2 3 18 6 19 165 3.5 0.2 3.8 2.8 05/01/2007 20:20:00 5.5 0.6 7.2 3.8 5.6 0.7 7.2 3.4 5.6 0.7 7.2 3.4 19 5 13 165 3.5 0.2 3.8 2.8 05/01/2007 20:30:00 5 0.5 6.5 3.8 5.1 0.7 6.8 2.6 5.2 0.5 6.5 3.8 19 6 14 165 3.5 0.2 3.8 2.8 05/01/2007 20:40:00 5.1 0.6 6.8 3.8 5.1 0.8 6.8 3 5.2 0.6 6.8 3.4 18 6 25 165 3.5 0.1 3.8 2.8 05/01/2007 20:50:00 5.3 0.7 6.8 2.6 5.3 0.8 7.2 2.6 5.5 0.7 7.2 3 18 6 20 165 3.5 0 3.5 3.3 05/01/2007 21:00:00 5.5 1 8.4 3 4.9 0.9 8 2.6 5.7 1 8.4 3.4 13 8 10 165 3.5 0 3.5 3.5 05/01/2007 21:10:00 5.6 1 8.8 2.6 5.5 1.1 8.4 2.6 5.7 1 8.4 2.6 20 8 18 165 3.5 0 3.5 3.3 05/01/2007 21:20:00 5.1 1 8.4 3 5.2 1 8.4 3 5.2 1 7.6 3 29 9 32 165 3.3 0 3.5 3 05/01/2007 21:30:00 5 0.7 6.8 3.4 5.1 0.9 6.8 2.6 5.3 0.8 7.6 3.4 25 9 19 165 3.4 0 3.5 3 05/01/2007 21:40:00 4.2 1 9.5 2.3 4.3 0.9 8 2.6 4.4 0.9 8.4 3 31 13 11 165 3.5 0 3.8 3.3 05/01/2007 21:50:00 5.7 1 8 3 5.9 1 8 3.4 5.8 0.9 7.6 3.8 30 8 32 165 3.6 0 3.8 3.3 05/01/2007 22:00:00 5.9 0.9 8.4 3.4 6.1 0.8 8.4 3.4 6 0.9 8.4 4.2 34 11 37 165 3.6 0 3.8 3.5 05/01/2007 22:10:00 5.5 1 8 3 5.7 1 8 3.4 5.8 1 8.4 3.8 29 8 34 165 3.5 0 3.8 3.3 05/01/2007 22:20:00 4.4 1.1 7.6 2.6 4.5 1.1 7.6 2.3 4.6 1 7.6 3 30 10 23 165 3.5 0 3.5 3.3 05/01/2007 22:30:00 4.1 1 7.2 2.3 4.1 1 7.6 2.3 4.2 1.2 7.6 1.9 30 11 39 165 3.5 0 3.5 3 05/01/2007 22:40:00 4.3 0.7 6.8 2.6 4.4 0.7 6.8 2.3 4.5 0.7 6.8 2.6 23 9 22 165 3.3 0 3.5 3 05/01/2007 22:50:00 4.8 0.8 8 3 4.8 0.9 7.6 2.6 4.9 0.8 7.2 2.6 22 12 14 165 3.3 0 3.5 2.8 05/01/2007 23:00:00 4.8 1.4 9.1 2.6 4.7 1.2 8.4 2.3 4.6 1.2 8.4 2.3 16 15 353 165 3.2 0 3.3 2.8 05/01/2007 23:10:00 6.8 1.7 10.3 2.3 5.9 1.3 9.1 2.3 6.1 1.7 9.9 1.9 4 11 353 165 3.2 0 3.3 2.8 05/01/2007 23:20:00 7.8 1 10.7 5.3 6.1 1.1 9.5 3.4 7.5 0.9 10.3 4.9 0 7 360 165 3.2 0 3.5 3 05/01/2007 23:30:00 7.2 1.4 10.7 4.2 6.3 1.4 9.5 3 7.1 1.2 11.1 4.6 6 7 3 165 3.2 0 3.3 3 05/01/2007 23:40:00 7.1 1.2 9.9 4.6 5.8 1.1 8.4 2.6 7.1 1.1 9.9 4.9 3 6 7 165 3 0 3.3 2.8 05/01/2007 23:50:00 7.4 1.2 9.9 4.2 6.5 1 9.1 3 7.2 1.1 10.3 4.2 8 7 2 165 2.9 0 3.3 2.8 05/02/2007 00:00:00 6.1 0.9 8.4 3.8 5.3 0.8 7.6 3.4 6.3 0.8 8.4 4.2 7 7 0 165 2.8 0 3 2.6 05/02/2007 00:10:00 7 0.9 9.1 4.9 5.8 1 8.4 3.4 7.1 0.8 9.1 4.6 5 6 7 165 2.7 0 2.8 2.6 05/02/2007 00:20:00 7.7 1 9.9 5.7 6.4 1.3 9.5 3.4 7.6 0.8 9.5 4.9 6 6 9 165 2.6 0 2.8 2.6 05/02/2007 00:30:00 8.3 1.1 10.7 5.7 6.9 1.1 9.5 3.8 8 1.2 10.7 5.7 5 5 7 165 2.6 0 2.8 2.6 05/02/2007 00:40:00 9 0.9 11.1 6.5 8.2 1.2 11.1 4.2 8.8 1 11.5 6.5 8 6 10 165 2.8 0 3 2.6 05/02/2007 00:50:00 9.5 0.8 11.5 6.8 8.9 1.2 11.5 5.3 9.3 0.9 11.5 6.8 11 5 16 165 2.9 0 3 2.6 05/02/2007 01:00:00 9.4 1 11.8 6.5 8.9 1.4 11.8 3.8 9 1.2 11.8 6.1 12 6 15 165 2.8 0 3 2.6 05/02/2007 01:10:00 8.4 1 10.7 5.3 7.4 1.2 10.3 4.6 8.3 1 10.3 5.7 7 6 2 165 2.7 0 2.8 2.6 05/02/2007 01:20:00 8.8 1 11.1 6.1 7.2 1.2 10.3 4.2 8.7 0.9 11.5 6.5 3 7 2 165 2.7 0 2.8 2.6 05/02/2007 01:30:00 8.3 1.1 10.3 4.9 6.5 1.2 9.5 3.8 8.2 1.1 11.1 5.3 2 7 358 165 2.7 0 2.8 2.6 05/02/2007 01:40:00 7.4 1 10.3 4.9 5.7 1.1 9.1 3 7.3 0.9 9.5 4.9 2 6 10 165 2.6 0 2.8 2.6 05/02/2007 01:50:00 7.5 0.9 9.5 5.3 5.8 1.1 8.8 3.4 7.4 0.9 10.3 4.9 2 6 358 165 2.7 0 2.8 2.1 05/02/2007 02:00:00 6.7 0.7 8.4 4.6 5 0.9 7.6 3 6.8 0.8 8.8 3.8 1 6 12 165 2.6 0 2.8 2.6 05/02/2007 02:10:00 5.9 1 8.4 3.8 5.1 1 7.2 2.6 6.1 1 8.8 3.4 6 6 3 165 2.4 0 2.6 2.3 05/02/2007 02:20:00 5.1 0.9 7.2 3.4 4.5 1 7.2 1.9 5.1 0.8 7.6 3.8 5 8 5 165 2.6 0 2.8 2.6 05/02/2007 02:30:00 6.2 0.8 8.8 4.6 5.1 1.2 9.1 3 6.3 0.8 8.4 4.6 3 7 14 165 2.7 0 2.8 2.3 05/02/2007 02:40:00 6.3 0.9 8.4 4.2 5.2 1 7.6 3.4 6.5 0.8 8.8 4.6 2 6 5 165 2.7 0 2.8 2.3 05/02/2007 02:50:00 6.6 0.6 8.8 4.9 5 0.9 7.6 2.6 6.8 0.6 8.4 5.3 0 5 5 165 2.7 0 2.8 2.3 05/02/2007 03:00:00 6 0.7 7.2 3.8 4.9 1 7.2 2.3 6.2 0.8 8 3.8 2 7 1 165 2.8 0 3.3 2.6 05/02/2007 03:10:00 5.3 0.6 6.8 3.4 4.6 0.9 6.8 2.6 5.4 0.7 6.8 3.4 5 7 5 165 2.9 0 3 2.6 05/02/2007 03:20:00 5.1 0.7 6.8 3.4 4 0.9 6.1 1.5 5.2 0.7 6.8 3.8 1 7 3 165 2.9 0 3 2.6 05/02/2007 03:30:00 6 0.7 7.6 3.8 5 1 7.6 2.3 6 0.7 8 4.2 2 7 8 165 2.9 0 3 2.6 05/02/2007 03:40:00 6.2 0.7 8.4 4.2 5.4 0.9 8 2.6 6.3 0.7 8 4.2 5 5 13 165 2.9 0 3 2.8 05/02/2007 03:50:00 5.3 0.7 6.8 3 4.8 0.9 7.2 2.6 5.4 0.6 7.2 3.8 6 7 5 165 2.9 0 3 2.8 05/02/2007 04:00:00 5.2 0.8 7.2 3.4 4.9 0.8 6.8 2.3 5.3 0.8 7.6 3.4 7 6 360 165 2.9 0 3 2.8 05/02/2007 04:10:00 4.3 0.6 5.7 3 4.4 0.6 5.7 2.6 4.4 0.6 6.1 3 19 8 23 165 2.9 0 3 2.8 05/02/2007 04:20:00 4.1 0.5 5.3 3 4.3 0.5 5.7 3 4.4 0.5 5.7 3 23 8 32 165 2.8 0 3 2.6 05/02/2007 04:30:00 3.2 0.7 4.9 1.5 2.9 1 5.3 0.7 3.1 0.8 5.3 1.5 13 12 20 165 2.8 0 3 2.6 05/02/2007 04:40:00 3.7 0.7 5.3 2.3 3.2 0.9 5.3 1.1 3.6 0.8 5.7 1.9 4 9 359 165 2.9 0 3 2.8 05/02/2007 04:50:00 3.9 0.5 5.3 2.6 3.7 0.6 4.9 1.5 4.1 0.5 4.9 2.6 9 6 7 165 2.9 0 3 2.8 05/02/2007 05:00:00 3.5 0.5 4.9 2.3 2.8 0.8 4.9 1.1 3.7 0.5 5.3 2.3 3 7 18 165 2.9 0 3 2.8 05/02/2007 05:10:00 3.9 0.7 5.7 2.3 3.4 0.7 4.9 1.9 4.3 0.8 5.7 2.6 7 5 4 165 2.7 0 3 2.6 05/02/2007 05:20:00 2.6 0.3 3.4 1.9 1.1 0.6 2.6 0.4 2.5 0.4 3.4 1.5 359 6 355 165 2.6 0 2.8 2.6 05/02/2007 05:30:00 2.6 0.4 3.8 1.5 1.3 0.7 3.4 0.4 2.4 0.4 3.4 1.5 360 6 6 165 2.6 0 2.8 2.6 05/02/2007 05:40:00 1.9 0.4 3 0.7 1.5 0.5 3 0.4 1.6 0.5 3 0.7 310 22 343 165 2.6 0.1 2.8 2.3 05/02/2007 05:50:00 1.7 1 4.9 0.4 1.4 1 4.9 0.4 1.4 0.7 3 0.4 308 22 333 165 2.5 0 2.8 2.3 05/02/2007 06:00:00 1.2 0.7 2.6 0.4 0.7 0.5 2.3 0.4 1.1 0.6 2.6 0.4 329 27 343 165 2.6 0 2.8 2.6 05/02/2007 06:10:00 1.7 0.5 2.6 0.4 0.9 0.5 2.3 0.4 1.6 0.5 2.6 0.4 343 14 323 165 2.6 0 2.8 2.6 05/02/2007 06:20:00 1.9 0.4 3.4 1.1 1.2 0.6 3 0.4 1.8 0.4 3 0.7 340 12 329 165 2.6 0 2.8 2.6 05/02/2007 06:30:00 1.6 0.4 2.6 0.4 1 0.5 2.3 0.4 1.4 0.4 2.3 0.4 334 16 317 165 2.7 0 2.8 2.6 05/02/2007 06:40:00 1.5 0.5 2.6 0.4 1 0.6 2.6 0.4 1.4 0.5 2.6 0.4 356 17 19 165 2.7 0 3 2.6 05/02/2007 06:50:00 1 0.3 1.9 0.4 0.5 0.2 1.1 0.4 1 0.5 2.3 0.4 0 6 3 165 2.7 0 2.8 2.1 05/02/2007 07:00:00 0.7 0.2 1.5 0.4 0.4 0.1 0.7 0.4 0.8 0.4 1.5 0.4 355 6 1 165 2.7 0 2.8 2.1 05/02/2007 07:10:00 0.4 0.1 1.1 0.4 0.4 0 0.4 0.4 0.4 0.1 1.1 0.4 2 0 2 165 2.7 0.1 3 2.3 05/02/2007 07:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 349 26 165 165 2.8 0.1 3 2.3 05/02/2007 07:30:00 0.4 0.1 0.7 0.4 0.4 0 0.7 0.4 0.4 0.1 1.1 0.4 267 22 253 165 3 0.1 3.3 2.6 05/02/2007 07:40:00 0.7 0.2 1.1 0.4 0.6 0.3 1.1 0.4 0.9 0.3 1.5 0.4 276 6 283 165 2.9 0 3 2.6 05/02/2007 07:50:00 0.4 0.1 1.1 0.4 0.4 0.1 1.1 0.4 0.5 0.2 1.5 0.4 281 15 267 165 2.9 0 3 2.6 05/02/2007 08:00:00 0.8 0.5 1.9 0.4 0.7 0.4 1.5 0.4 0.9 0.5 1.9 0.4 281 1 281 165 2.9 0 3 2.8 05/02/2007 08:10:00 0.7 0.3 1.5 0.4 0.7 0.3 1.5 0.4 1.2 0.4 1.9 0.4 265 11 281 165 2.9 0 3 2.6 05/02/2007 08:20:00 0.5 0.3 1.9 0.4 0.6 0.3 1.5 0.4 1 0.4 1.9 0.4 256 9 267 165 3 0 3.3 2.8 05/02/2007 08:30:00 0.5 0.2 1.5 0.4 0.4 0.2 1.5 0.4 0.6 0.4 1.9 0.4 251 9 243 165 3 0 3 2.8 05/02/2007 08:40:00 0.6 0.3 1.5 0.4 0.5 0.2 1.5 0.4 0.9 0.3 1.5 0.4 234 12 222 165 3 0 3.3 2.8 05/02/2007 08:50:00 0.7 0.5 2.3 0.4 0.6 0.5 2.6 0.4 1 0.6 2.6 0.4 200 22 166 165 3 0.2 3.3 2.6 05/02/2007 09:00:00 2.8 0.6 4.2 1.9 2.8 0.6 4.2 1.5 2.8 0.5 3.8 1.5 154 12 151 165 2.9 0 3.3 2.8 05/02/2007 09:10:00 3.3 0.6 4.9 1.9 3.3 0.6 4.9 1.9 3.5 0.5 4.9 2.3 162 15 140 165 2.9 0 3.3 2.8 05/02/2007 09:20:00 4.5 0.5 5.7 3.4 4.4 0.4 5.7 3.4 4.7 0.4 6.1 3.8 148 8 160 165 2.8 0 3 2.6 05/02/2007 09:30:00 5.3 0.5 6.5 4.2 5.3 0.5 6.5 3.8 5.5 0.6 6.8 3.8 151 9 145 165 2.7 0 3 2.6 05/02/2007 09:40:00 5.7 0.5 6.8 4.2 5.6 0.4 6.5 4.2 6 0.4 7.2 4.6 149 10 161 165 2.6 0 2.8 2.6 05/02/2007 09:50:00 6.8 0.8 8.8 4.9 6.6 0.8 8.4 4.6 6.9 0.8 8.8 4.9 159 17 169 165 2.7 0 2.8 2.6 05/02/2007 10:00:00 8.2 0.5 9.1 6.5 7.9 0.5 9.1 6.1 8.2 0.5 9.1 6.8 162 22 165 165 2.6 0 2.8 2.3 05/02/2007 10:10:00 9.1 0.8 11.1 7.2 8.8 0.8 10.7 6.8 9.1 0.9 11.5 6.8 170 12 167 165 2.6 0 2.8 2.3 05/02/2007 10:20:00 9.3 0.8 10.7 7.2 8.9 0.8 10.7 7.2 9.2 0.8 11.1 7.6 172 8 179 165 2.4 0 2.6 2.3 05/02/2007 10:30:00 8.4 0.7 9.5 6.5 8 0.7 9.1 6.5 8.4 0.8 10.3 6.1 173 7 173 165 2.4 0 2.6 2.3 05/02/2007 10:40:00 8.1 0.7 9.9 6.1 7.7 0.6 9.1 6.1 8.2 0.7 9.9 5.7 172 6 173 165 2.6 0.1 2.8 1.8 05/02/2007 10:50:00 9.2 0.8 11.1 7.2 8.8 0.7 10.7 7.2 9.2 0.8 11.1 7.2 168 16 165 165 2.6 0 2.8 1.8 05/02/2007 11:00:00 8.4 0.7 10.7 6.1 8 0.6 9.9 6.1 8.5 0.7 10.3 6.8 171 7 175 165 2.6 0 2.8 1.8 05/02/2007 11:10:00 8.1 0.5 9.5 6.8 7.8 0.5 9.1 6.5 8.3 0.6 9.5 6.8 171 9 157 165 2.7 0 2.8 2.1 05/02/2007 11:20:00 7.8 0.8 9.9 6.1 7.5 0.8 9.5 5.7 7.9 0.7 9.9 6.5 180 10 167 165 3 0.1 3.3 2.3 05/02/2007 11:30:00 7.7 0.9 9.9 5.7 7.5 0.9 9.5 5.3 7.8 1 9.9 5.7 183 10 172 165 3 0.1 3.3 2.3 05/02/2007 11:40:00 7 1.1 9.9 4.2 6.8 1.1 9.5 4.2 7.2 1.1 10.3 4.9 182 9 195 165 3.2 0.1 3.5 2.6 05/02/2007 11:50:00 6.4 0.7 8.4 4.6 6.2 0.7 8 4.6 6.5 0.7 8.4 4.6 191 8 192 165 3.6 0.2 4.3 2.8 05/02/2007 12:00:00 6.4 0.6 7.6 4.6 6.2 0.6 7.6 4.2 6.4 0.6 8 4.6 190 9 197 165 3.8 0.2 4.5 3.3 05/02/2007 12:10:00 6.5 0.8 9.1 4.6 6.3 0.8 8.4 4.6 6.5 0.7 8.8 4.6 179 17 206 165 4.3 0.2 4.8 3.5 05/02/2007 12:20:00 8.8 1.5 13 6.1 8.5 1.7 12.6 5.3 9 1.6 13.3 6.1 167 12 167 165 4 0.1 4.5 3.3 05/02/2007 12:30:00 11.6 0.8 13.7 9.1 11.4 0.8 13.3 9.1 11.8 0.8 13.7 8.8 167 16 181 165 4.2 0.1 4.8 3.5 05/02/2007 12:40:00 11.8 0.4 12.6 9.5 11.4 0.4 12.6 9.1 11.9 0.6 13.3 9.9 162 18 183 165 4.2 0 4.5 4 05/02/2007 12:50:00 11.9 0.5 13 9.9 11.5 0.4 12.6 9.9 12.1 0.5 13.3 10.3 162 19 139 165 4.3 0.2 4.8 3.5 05/02/2007 13:00:00 11.3 0.6 13 9.5 10.9 0.6 12.6 9.1 11.6 0.6 13.7 10.3 167 18 165 165 4.2 0.2 4.8 3.3 05/02/2007 13:10:00 11.7 0.6 13.3 10.3 11.3 0.5 13 9.9 12 0.6 13.7 9.9 167 22 165 165 4.3 0.1 4.8 3.8 05/02/2007 13:20:00 10.9 0.6 12.2 9.1 10.5 0.6 11.8 8.8 11.1 0.7 12.6 8.8 166 15 157 165 4.4 0.1 5 4 05/02/2007 13:30:00 10.4 0.7 11.8 8.8 10 0.6 11.5 8.4 10.7 0.7 12.6 8.8 163 15 172 165 4.6 0.1 5 4.3 05/02/2007 13:40:00 11.3 0.5 12.6 9.9 10.8 0.5 12.6 9.5 11.6 0.6 13.3 9.5 167 19 165 165 4.4 0.2 5 3.8 05/02/2007 13:50:00 11.7 0.6 13.3 9.9 11.3 0.6 13 9.9 12 0.7 13.7 9.9 166 22 135 165 4.6 0.1 5 4.5 05/02/2007 14:00:00 11.7 0.5 13 10.3 11.3 0.5 12.2 9.9 12 0.6 13.3 10.3 161 17 165 165 4.7 0.1 5 4.5 05/02/2007 14:10:00 10.6 0.4 11.5 9.5 10.1 0.4 11.1 9.1 10.8 0.5 11.8 8.8 160 17 160 165 4.4 0.1 4.8 4.3 05/02/2007 14:20:00 10.9 0.5 12.2 9.5 10.4 0.5 11.5 9.1 11.1 0.5 11.8 9.1 160 20 160 165 4.6 0.1 5 4.3 05/02/2007 14:30:00 10.7 0.4 11.5 9.1 10.3 0.4 11.5 8.8 11 0.4 11.8 9.5 160 17 161 165 4.7 0.1 5 4.3 05/02/2007 14:40:00 11.5 1 13.3 9.1 11.2 1 13.3 9.1 11.8 1 14.5 9.5 154 11 155 165 4.1 0.2 4.5 3.5 05/02/2007 14:50:00 11.8 0.9 13.3 9.1 11.5 0.9 13 8.8 11.9 1 13.7 8.8 152 6 151 165 3.3 0.1 3.5 2.8 05/02/2007 15:00:00 10.7 1 13 8 10.5 0.9 12.6 8 10.8 0.9 13.3 8.8 152 12 165 165 3.5 0.2 3.8 2.8 05/02/2007 15:10:00 9.9 0.7 11.5 8.4 9.7 0.7 11.5 8 10 0.8 12.2 8 154 9 151 165 3.6 0 4 3.5 05/02/2007 15:20:00 9.5 0.6 11.1 8 9.3 0.6 11.1 8 9.8 0.6 11.5 8.4 153 8 159 165 4.1 0.2 4.5 3.5 05/02/2007 15:30:00 8.9 0.6 10.7 7.2 8.6 0.6 10.3 6.8 9 0.7 10.7 6.8 152 5 151 165 3.9 0.2 4.5 3.3 05/02/2007 15:40:00 8.1 0.5 9.5 6.8 7.9 0.5 9.1 6.5 8.3 0.5 9.5 6.8 160 9 154 165 4.1 0.2 4.5 3.3 05/02/2007 15:50:00 8.4 0.6 9.9 6.8 8.2 0.5 9.9 6.5 8.6 0.5 9.9 6.8 157 11 150 165 4.4 0.2 5 4 05/02/2007 16:00:00 8.2 0.4 9.1 6.5 7.9 0.4 8.8 6.8 8.4 0.4 9.5 6.8 152 4 151 165 4.3 0.3 4.8 3.5 05/02/2007 16:10:00 8.3 0.3 9.1 7.6 8 0.3 8.8 7.2 8.4 0.4 9.5 7.2 155 2 156 165 3.6 0.1 4 3.3 05/02/2007 16:20:00 8 0.3 8.8 7.2 7.7 0.3 8.4 6.8 8.1 0.4 8.8 6.5 155 2 153 165 3.6 0.1 4.3 3.5 05/02/2007 16:30:00 7.4 0.5 9.1 6.1 7.2 0.4 8.8 6.1 7.5 0.5 8.8 6.5 156 6 162 165 4 0.3 4.5 3 05/02/2007 16:40:00 7.5 0.4 8.4 6.1 7.1 0.3 8 6.1 7.7 0.4 8.4 6.5 163 12 163 165 4.2 0.1 4.5 3.8 05/02/2007 16:50:00 7.4 0.4 8.4 6.1 7.2 0.4 8.4 6.1 7.5 0.5 8.4 6.5 159 12 159 165 4.4 0.1 4.8 4 05/02/2007 17:00:00 7.5 0.8 9.1 5.7 7.4 0.8 9.1 5.7 7.6 0.8 9.5 6.1 144 6 143 165 4.4 0.1 4.8 4 05/02/2007 17:10:00 8.8 0.5 10.3 7.2 8.6 0.5 10.3 6.8 8.7 0.5 9.9 7.2 143 4 138 165 4.3 0.2 4.8 3.5 05/02/2007 17:20:00 9 0.5 10.3 8 8.9 0.5 9.9 7.2 8.9 0.5 10.3 7.6 146 3 147 165 3.6 0 3.8 3.5 05/02/2007 17:30:00 9.2 0.6 10.7 7.2 9.2 0.6 10.3 7.2 9.3 0.7 10.3 7.6 146 4 149 165 3.3 0 3.8 2.8 05/02/2007 17:40:00 9.1 0.5 10.3 7.2 9.1 0.5 9.9 7.6 9 0.6 10.3 6.8 142 4 146 165 3.2 0 3.5 2.8 05/02/2007 17:50:00 9.3 0.5 10.7 7.6 9.4 0.5 11.1 7.6 9.3 0