HomeMy WebLinkAboutMiddleton-Isl-Old_longterm-dataMIDDLETON ISL. AMOS AK - 703431 59 deg 26' N 146 deg 20' W - Elev 14m LST=GMT+99 hours *NT=-10 01/73-11/77 Adjusted to Alaska Timezone (GMT-9) SPEED BY YEAR Year ALL JAN FEB MAR APR MAY JUN JUL AUG SEP OCT NOV DEC ALL 6.1 6.69 7.54 6.38 6.39 6.01 4.29 3.97 4.57 5.83 7.03 7.26 8.19 1973 5.75 7.38 5.68 6.24 5.76 7.38 4.91 3.85 4.45 4.88 6.07 6.27 7.39 1974 5.98 2.23 8.09 6.68 6.44 5.27 4.28 3.75 4.71 6.13 8.5 8.64 7.74 1975 6.17 8.34 8.62 6.11 5.33 6.38 4.8 4.25 4.8 5.74 6.74 6.52 14.2 1976 6.52 7.46 6.23 6.7 6.72 6.14 4.52 3.77 4.28 7.18 6.18 8.97 9.23 1977 5.98 8.29 8.47 6.15 7.22 5.49 3.46 4.17 4.49 4.87 7.73 5.42 -1 POWER BY YEAR Year ALL JAN FEB MAR APR MAY JUN JUL AUG SEP OCT NOV DEC ALL 369 551 577 380 409 269 102 83 136 287 506 607 671 1973 324 523 276 406 337 418 144 87 126 184 366 536 579 1974 358 82 563 460 393 187 97 77 131 247 787 833 555 1975 377 783 1013 361 234 282 129 99 147 304 341 421 2154 1976 419 615 280 359 464 288 116 67 166 490 384 887 841 1977 355 724 658 346 549 230 56 84 122 168 674 284 -1 NUMBER OF SPEED OBSERVATIONS BY YEAR Year ALL JAN FEB MAR APR MAY JUN JUL AUG SEP OCT NOV DEC ALL 33880 2698 2621 3015 2488 2938 2622 3264 2976 3185 3433 2649 1991 1973 5855 287 305 404 336 384 426 609 621 621 647 562 653 1974 6824 605 459 523 567 595 586 547 565 656 617 475 629 1975 6540 574 571 622 414 525 426 648 709 688 701 650 12 1976 7609 489 674 723 695 695 473 742 391 700 724 606 697 1977 7052 743 612 743 476 739 711 718 690 520 744 356 0 NUMBER OF SPEED OBSERVATIONS BY HOUR Hour ALL JAN FEB MAR APR MAY JUN JUL AUG SEP OCT NOV DEC 0 1439 110 109 129 111 128 114 137 119 137 143 117 85 1 1421 110 109 123 109 121 113 139 122 137 144 111 83 2 1430 107 113 133 101 128 118 141 125 132 138 114 80 3 1370 105 106 119 93 111 108 133 125 132 147 111 80 4 1433 109 109 130 110 133 115 134 121 129 145 113 85 5 1412 106 108 126 111 129 117 136 122 134 138 104 81 6 1411 107 111 121 103 129 113 137 124 133 137 109 87 7 1395 107 105 117 104 124 113 137 126 132 140 105 85 8 1393 109 104 123 98 122 111 142 123 132 141 106 82 9 1336 101 111 107 97 112 88 130 132 131 143 107 77 10 1418 110 106 129 97 127 105 142 126 132 144 112 88 11 1425 114 113 122 105 122 106 136 125 132 145 118 87 12 1422 118 109 129 99 118 111 135 130 133 147 111 82 13 1446 118 107 126 104 128 117 142 130 137 144 111 82 14 1420 119 114 129 109 124 103 138 121 133 148 102 80 15 1231 111 94 112 80 90 77 111 115 121 138 104 78 16 1425 113 112 133 111 121 105 135 125 135 144 111 80 17 1430 121 109 124 108 128 116 138 119 131 146 107 83 18 1419 122 104 124 104 119 108 135 129 133 142 115 84 19 1462 117 109 140 112 130 115 137 126 133 143 111 89 20 1439 117 119 131 101 119 118 135 124 132 147 110 86 21 1410 111 116 126 101 121 104 139 124 133 139 116 80 22 1455 123 118 135 106 125 113 136 127 133 144 111 84 23 1438 113 106 127 114 129 114 139 116 138 146 113 83 SPEED BY HOUR Hour ALL JAN FEB MAR APR MAY JUN JUL AUG SEP OCT NOV DEC 0 5.94 6.71 7.7 6.48 6.13 5.63 3.93 3.45 4.52 5.72 6.81 7.2 7.99 1 5.92 6.93 7.54 6.21 6.35 5.67 3.89 3.44 4.47 5.58 6.9 7.28 8 2 5.97 6.9 7.72 6.25 6.44 5.76 4.06 3.44 4.48 5.67 6.75 7.48 8.22 3 5.96 6.34 7.66 6.51 6.36 5.46 3.86 3.53 4.23 5.78 7.02 7.8 8 4 5.9 6.16 7.66 6.24 6.06 5.82 3.9 3.54 4.3 5.59 6.65 7.54 8.45 5 5.94 6.72 7.73 6.6 6.07 5.74 4.15 3.45 4.29 5.63 6.77 7.28 8.36 6 6.05 6.64 7.97 6.76 5.85 5.68 4.07 3.54 4.32 5.77 6.82 7.58 8.91 7 5.97 6.68 7.94 6.38 5.51 5.96 4.31 3.75 4.19 5.68 6.75 7.01 8.94 8 6.1 6.42 7.34 6.64 6.1 6 4.41 3.97 4.31 5.75 7.05 7.6 9.05 9 6.16 6.63 7.3 6.55 6.38 6.03 4.31 4.2 4.61 5.85 7.19 7.19 8.57 10 6.28 6.49 7.85 6.34 6.37 6.37 4.84 4.3 4.77 5.96 7.09 7.52 8.48 11 6.31 6.94 7.6 6.36 6.45 6.3 4.73 4.38 4.63 5.99 7.33 7.57 7.97 12 6.34 6.7 7.76 6.5 6.54 6.32 4.8 4.78 4.97 6.22 7.25 7.32 7.53 13 6.35 6.97 7.44 6.37 6.59 6.35 4.97 4.66 5.06 6.27 7.31 7.12 8.02 14 6.28 6.78 7.32 6.21 6.34 6.36 4.88 4.62 5.15 6.18 7.44 6.94 7.56 15 6.37 6.62 7.39 6.42 6.81 6.85 4.88 4.57 4.92 6.15 7.32 6.71 8.14 16 6.2 6.5 7.28 6.21 6.68 6.56 4.83 4.47 4.77 5.81 7.16 6.86 7.99 17 6.21 6.83 7.6 6.13 6.81 6.35 4.64 4.45 4.78 5.88 7 7.02 7.82 18 6.12 6.68 7.45 6.06 6.88 6.06 4.31 4.33 4.7 5.68 7.1 6.9 8.27 19 6.01 6.87 6.6 6.18 6.83 5.94 4.24 3.97 4.38 5.69 7.3 6.88 8.04 20 5.93 6.85 7.29 6.22 6.15 5.78 3.99 3.74 4.44 5.74 6.95 7.05 7.67 21 5.98 6.73 7.75 6.56 6.58 5.63 3.83 3.48 4.29 5.77 6.69 7.29 8.2 22 6.03 6.72 7.56 6.56 6.59 5.89 3.68 3.65 4.35 5.74 6.9 7.45 8.1 23 6.04 6.73 7.43 6.41 6.54 5.82 3.77 3.57 4.8 5.76 7.04 7.51 8.12 POWER BY HOUR Hour ALL JAN FEB MAR APR MAY JUN JUL AUG SEP OCT NOV DEC 0 357 601 557 401 413 247 79 60 142 288 442 580 632 1 347 626 579 319 441 273 80 60 136 254 457 553 548 2 362 661 637 389 427 270 87 62 114 274 417 595 627 3 361 550 599 435 411 230 77 63 111 276 450 663 634 4 346 548 577 346 353 270 77 68 112 277 452 612 607 5 350 541 592 403 353 260 130 68 119 297 445 495 710 6 363 545 638 436 319 256 93 69 123 299 482 614 654 7 369 538 690 406 275 280 133 80 129 288 443 517 916 8 367 519 481 381 318 291 101 93 139 280 531 631 872 9 376 480 455 408 397 255 97 98 161 308 567 631 795 10 389 497 667 380 370 278 137 96 155 285 535 671 786 11 401 626 595 419 370 315 115 99 130 265 575 725 671 12 383 518 600 397 369 287 117 118 172 317 576 621 600 13 387 546 612 411 377 302 136 111 190 309 529 580 747 14 371 525 558 381 325 299 125 105 173 290 547 599 631 15 384 539 573 391 422 297 119 107 140 317 563 474 672 16 384 509 590 347 420 290 130 97 132 270 619 615 737 17 378 567 621 321 461 282 116 102 134 290 521 639 628 18 366 544 562 290 482 259 99 90 128 282 527 620 651 19 353 543 373 351 529 237 101 77 117 265 572 562 637 20 356 598 559 328 428 227 81 72 124 309 509 595 543 21 379 578 636 411 558 229 78 62 119 304 415 682 650 22 368 526 556 398 518 271 73 71 132 278 474 644 614 23 357 501 542 384 460 256 73 60 133 280 507 633 592 SPEED BY DIRECTION Month calm 0 10 20 30 40 50 60 70 80 90 100 110 120 130 140 150 160 170 180 190 200 210 220 230 240 250 260 270 280 290 300 310 320 330 340 350 360 ALL 0 5.13 4.77 4.42 4.82 4.92 5 5.36 5.99 6.9 7.13 7.8 7.99 7.74 6.92 6.95 5.9 5.58 4.96 4.68 4.7 5.17 4 4.06 4.69 4.72 5.09 5.73 5.51 5.87 5.33 4.98 5.32 5.38 6.47 6.57 4.44 5.13 1 0 3.1 5.4 4.5 5.1 4.6 3.6 5.8 6.1 4.7 7 9.7 9.1 9.3 7.6 8.3 6.5 5.9 5.7 5.6 6 5.9 5.4 5.8 4.9 6.6 6.7 8.2 5 7.2 6.3 3.4 5.8 4.4 8.3 8.6 6 3.1 2 0 6.2 5.6 6.2 5.9 6.4 7.1 6.4 6.6 7.8 9.2 10 10 9.8 9.5 8 7.3 6.6 6 5.3 5.1 4.1 4 4.2 6.5 7.6 6.8 7.6 7.6 6.9 6.4 5.6 7.7 7.2 7.1 4 4.1 6.2 3 0 6.5 6.7 5.2 4.4 4.3 5 4.8 6.9 7.6 7.5 6.6 8.9 7.7 6.8 6.2 6.1 5.2 4.9 5 4.1 5.4 5 4.6 5.1 5.5 6.2 5.8 6.9 7.7 8.7 5.4 6.4 6.2 7.3 5.4 3.8 6.5 4 0 4.4 4.8 4 5.3 3.7 4.5 5 5.1 7.2 7 8.7 8 8.4 7.5 7.1 5.2 5.9 5.3 5.3 4.4 4.8 4.9 4.2 3.7 3.3 3.9 8.9 6 5.6 5.1 5.4 6.1 6.5 5.4 6.2 4.8 4.4 5 0 3.6 2.3 3.3 3.1 3.6 5.2 6.7 5.7 6.8 7.3 7.4 8.7 6 6.8 6 6.1 4.4 4.1 3.3 3.2 6.7 3 2.8 3.3 3.5 5 5.6 5.7 5.5 4.7 4.5 3.7 3.8 3.4 2.7 2.5 3.6 6 0 3 4.2 4.6 3.3 3.4 3.6 4.5 4 5.5 5.2 5.5 5.4 4.6 4.6 4 3.1 3.4 3.5 2.4 3.4 2.1 2.6 2.6 3.1 4.2 5.2 5.3 4.3 4.2 3.9 3.7 3 2.3 2.1 3.1 2.3 3 7 0 1.7 1.4 1.7 2.5 2.1 3.4 3.9 4.3 4.7 4.4 5 4.4 4.2 4.1 3.3 2.5 2.8 2.6 2.4 3.5 2.5 2.2 2.5 2.7 3.2 3.7 4.6 4.8 4.5 3.5 3.3 2.3 2.6 1.9 1.9 2.4 1.7 8 0 3.8 2.2 2.5 3.6 3.7 3.6 3.8 5.1 6.1 5.4 6.2 5.7 5.7 3.6 3.7 4.4 4.1 3.2 2.9 5.3 2.5 2.4 2.7 3.1 3.4 3.9 4.5 4.2 5.2 4.5 4.9 3.4 4.2 7.9 4.4 2.5 3.8 9 0 2.9 3.6 3.6 4.9 4.5 4.3 4.5 7.1 7.1 8.6 7.1 7.7 7.2 6.3 7.5 5.9 5.5 4.6 4.6 4.6 4.2 3.9 3.9 4.5 4.1 4.9 5.1 4.6 4.4 4.6 5 4.5 4.9 4.5 5.2 4.7 2.9 10 0 5.5 4.6 4.7 4.1 5.6 4.4 6.9 8.2 9.4 9.1 8.6 9 9.4 7.5 7.6 7.7 7 5.7 4.8 4.5 4.4 4 4.3 4.7 5.7 5.6 5.3 7.5 5.5 6.9 7.4 4.2 4.2 8.5 10 6.5 5.5 11 0 9.1 8.5 4.4 5.6 5.6 5.4 6 7.2 9.1 8.7 9 9.4 9.2 7.4 9.6 7.6 6.9 6 5.5 5.1 4.6 4.6 4.9 5.4 3.9 6.3 6.3 7.3 7.3 7.3 6.7 7.2 7.4 8.1 7 5.6 9.1 12 0 6.3 6.1 5.8 3.6 6.1 5.9 5.2 6.2 8.7 8.7 12.2 10.3 11.8 9.8 9.3 6.5 7 6.2 5.8 5 6 6 5.1 6.1 6.3 6.4 9.3 7.9 9.9 7.6 6.4 7 6.2 5 7.3 3.8 6.3 FREQUENCY BY DIRECTION Month calm 0 10 20 30 40 50 60 70 80 90 100 110 120 130 140 150 160 170 180 190 200 210 220 230 240 250 260 270 280 290 300 310 320 330 340 350 360 ALL 2.97 1.72 0.7 0.87 1.22 2.2 2.92 2.3 2.56 4.69 6.06 6.93 6.86 5.7 3.78 5.21 3.57 3.13 2.55 1.87 3.06 2.38 1.14 1.36 1.8 1.49 2.09 3.18 4.52 3.6 3.01 1.94 1.23 1.03 1.11 1.51 0.7 1.72 1 15.4 1.6 1.1 2 3.6 5.9 3.7 1.8 2.4 7.1 6.6 7.6 7.8 7.2 3.6 3 3.4 2.5 1.6 1.7 2 0.7 1.1 1.1 1.4 0.9 1 0.9 1.9 4.1 2.4 1.3 1.4 0.6 1.1 3.5 0.4 1.6 2 1.4 0.8 0.9 1.6 2 3.5 5.3 3.5 2.9 3 7.5 7.3 6.1 4.4 5.5 4.1 4.7 2.8 3.3 2.7 3.1 0.6 0.6 1 2.6 0.9 0.9 2.4 3.7 2.3 1.9 1.5 1.5 1.6 1.1 1.7 0.5 0.8 3 2.6 2.8 0.9 1 2.1 2.2 4.1 3.8 2.7 3.7 4 4.8 7.7 5 2.9 6.2 2.7 3.1 1.8 1.7 1.9 0.8 1 1.4 2.8 2.2 2.8 2.1 4.3 4.8 1.8 1.2 1.9 1.7 2.4 2.5 1.2 2.8 4 2.5 1.7 0.5 0.8 1.2 0.9 3.5 1.9 1.7 4.1 5.2 9.4 8.5 8 5.1 5.2 4 3.9 4.2 1.9 2.6 5.2 1 1.2 0.8 0.8 0.8 1 2.1 1.9 2.2 1 1.2 1.7 1.4 2.2 1 1.7 5 0.7 1 0.3 0.5 0.4 0.9 2.6 2.1 3.2 3.2 6.8 7.8 10.4 5 3.5 3.2 2.9 2.4 3.3 1.1 1.3 10.3 1 1.1 1.2 0.9 2.4 5 5.5 3.2 3 1.7 0.8 0.6 0.7 0.5 0.3 1 6 1.3 1 0.5 0.7 0.7 1.7 1.1 2.1 3.6 4.8 7.6 5.8 6.1 4.2 2.9 4.4 3.8 3.2 1.6 1.4 2.5 1 0.7 1 1.4 2 4.7 5.8 7.6 5.5 4.1 2.7 1.2 0.8 0.8 0.5 0.7 1 7 2.4 1.1 0.6 0.5 0.3 0.8 1.5 1.8 3.4 7.1 10.1 10.8 7.4 5.4 4.2 3.8 2.3 1.4 1.7 1.1 2 1.3 1.2 1 1 1.5 2.4 3.8 8 4.7 2.9 2.2 0.7 0.6 0.6 0.5 0.5 1.1 8 2.3 2.1 0.7 0.6 0.4 0.8 0.6 2.3 1.8 2.3 3.5 6 4 6.9 2.7 3.8 2.7 2.5 1.2 0.8 8.7 1.7 1.2 1.1 1.4 1.7 3.7 5.3 9.3 6.1 5.5 3.5 1.1 1.1 0.8 1.1 0.6 2.1 9 1.5 1.5 0.9 0.5 0.5 0.6 2.3 1 2.2 5.2 4.3 6 8.3 5.4 3.2 8.8 4.6 4.6 3.2 2 2.7 2.1 1.1 1.8 1.7 2 2 3.2 2.8 3.2 4.7 3 1.4 0.9 0.8 0.9 0.5 1.5 10 1.5 2.6 0.7 1.1 0.9 2.8 2.3 2 2.6 6.9 5.8 5.5 5.2 5.1 3.5 5.2 4.3 4 3 2.6 3.3 1.5 1.7 2.1 3.1 1.4 1.3 3.3 2.6 1.7 3.2 1.5 0.9 0.8 1.7 2.4 1.6 2.6 11 2.4 3.3 0.9 0.9 2.4 5.8 6.2 2.7 2.2 3.6 5.9 4.9 4.5 5.7 4.2 7.4 3.4 3.6 2.9 3.2 2.6 1.6 1.2 1.9 1.7 1.1 0.8 1.5 1.5 2.6 2 1.6 1.7 1.2 1.2 1.2 0.5 3.3 12 2.6 0.5 0.1 0.2 0.4 0.8 2.3 3 1.6 4.5 5.5 7.7 6 6.9 4.7 8 4.3 3.8 3 2.4 4.1 1.9 1.8 1.7 2.6 2.7 2.3 3.4 4.2 2.7 1.5 2 0.9 0.8 0.6 1.2 0.3 0.5 FREQUENCY OF SPEED Month 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 ALL 3 6.7 11.4 13.1 11.8 10.5 9.3 7.7 5.9 4.9 3.6 2.9 2.3 1.9 1.5 1.3 0.8 0.3 0.4 0.3 0.2 0.1 0.1 0.1 0 0 1 15.4 4.9 6.7 7.2 6.7 7.5 7.3 7.6 5.9 6.1 5.2 4.4 2.9 3.1 2.5 2 1.7 0.8 0.7 0.6 0.3 0.2 0.2 0.2 0 0.1 2 1.4 3.6 7.3 9 9.8 9.2 10 8.9 7.6 7.2 5.6 4.3 4.2 3.9 2.1 2.4 1.1 0.2 0.5 0.4 0.4 0 0.5 0.3 0.1 0.1 3 2.6 6.4 9.9 11.6 11.4 9.2 9.6 9 6.8 6.1 4.6 3.5 2.8 2.1 1.6 0.7 0.7 0.2 0.5 0.4 0.1 0.1 0 0 0 0 4 2.5 6.5 10.3 11.6 11.9 11.1 7.9 8.5 6.7 5.6 3.6 3.4 2.9 1.8 1.5 1.8 0.9 0.4 0.4 0.4 0.4 0.1 0.1 0 0 0 5 0.7 4.5 9.2 14.3 13.5 13 11.4 8.9 7.9 5.4 3.6 2.5 1.5 1.2 0.9 0.8 0.5 0.1 0.1 0 0 0 0 0 0 0 6 1.3 9.9 19.1 18.6 15.8 11.9 10 6.1 3.7 1.4 0.9 0.6 0.4 0.2 0 0 0 0 0 0 0.1 0 0 0 0 0 7 2.4 12.6 20.1 20 15.5 10.5 7.3 5.4 2.9 1.8 0.7 0.4 0.2 0.2 0 0 0 0 0 0 0 0 0 0 0 0 8 2.3 9.5 17.2 18.6 13.6 12 9.7 6.6 3.9 2.3 1.3 0.9 0.6 0.6 0.4 0.2 0 0.1 0.1 0 0 0 0 0 0 0 9 1.5 6.8 12 13.3 11.5 12.5 11 8.6 6.6 4.3 2.9 2.4 1.5 1.3 1.3 1 0.7 0.3 0.3 0.1 0 0 0 0 0 0 10 1.5 5.4 8.6 10.9 10.8 10.3 9 8 6.7 6.1 5.1 4.5 2.7 2.4 2.2 2 0.9 0.3 0.7 0.6 0.3 0.4 0.1 0.3 0.1 0.1 11 2.4 5.5 8.9 10.8 10.4 10.1 8.4 7.4 5.1 5.1 4.3 4.2 3.8 2.9 3.2 2.2 2 0.4 0.6 0.7 0.3 0.3 0.3 0.4 0.2 0.1 12 2.6 2.9 4 8.7 8.7 8.1 9.4 7.5 8.3 8.9 6.2 4.9 4.9 3.8 2.7 3.1 1.7 0.5 0.9 0.6 0.5 0.5 0.4 0 0.1 0.1 PERCENT OF POWER BY SPEED Month 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 ALL 0 0 0.2 0.8 1.7 2.7 4 5.4 6.1 7 7 7.6 7.5 7.7 7.9 8.1 6.2 2.3 3.9 3.6 2.6 2 2.2 1.9 0.8 0.8 1 0 0 0.1 0.3 0.6 1.3 2.1 3.6 4 5.9 6.9 7.8 6.5 8.7 8.8 8.5 8.7 4.8 5.1 4.8 2.4 2 2.8 2.6 0 1.4 2 0 0 0.1 0.4 0.9 1.5 2.9 4 5 6.7 7 7.1 8.8 10.2 6.9 10 5.3 0.9 3 3 3.7 0.4 5.9 3.7 1.2 1.4 3 0 0 0.2 0.7 1.6 2.4 4.1 6.2 6.9 8.5 8.7 9 9.2 8.4 8.2 4.1 5.6 1.7 5.4 4.3 1.8 2.1 0 0 0.8 0 4 0 0 0.2 0.7 1.5 2.6 3.1 5.5 6.1 7.1 6.5 8.1 8.8 6.8 7.4 10.4 6.2 3 3.6 4.4 4.6 1.2 2 0 0 0 5 0 0 0.3 1.2 2.6 4.7 6.8 8.5 11.2 10.6 9.6 8.9 6.9 6.8 6.3 7.3 5.4 1.3 1 0.5 0 0 0 0 0 0 6 0 0.2 1.4 4.1 7.9 11 15.4 15.4 13.5 7.2 6.2 6 4.8 2.2 0.8 0 0 0 0 0 3.9 0 0 0 0 0 7 0 0.2 1.8 5.5 9.5 12 13.9 16.6 12.9 11.1 6.3 4.1 3.4 2.7 0 0 0 0 0 0 0 0 0 0 0 0 8 0 0.1 1 3.1 5.1 8.2 11.1 12.3 10.5 8.9 7 6.1 5.3 6.2 6.2 3.5 0 2.4 1.9 1 0 0 0 0 0 0 9 0 0 0.3 1 2.1 4.2 6 7.7 8.4 7.7 7.1 7.8 6.2 7.1 8.9 8.6 7.1 3.6 4.4 1.9 0 0 0 0 0 0 10 0 0 0.1 0.5 1.1 2 2.9 4 4.9 6.3 7 8.2 6.5 7 8.4 8.9 4.8 1.7 4.9 4.8 3.5 4.4 1.9 4 1 1.1 11 0 0 0.1 0.4 0.9 1.6 2.2 3.1 3.2 4.4 5.1 6.7 7.7 7.5 10.4 8.5 9.1 2.3 3.8 4.9 2.6 3.3 2.9 4.8 2.8 1.9 12 0 0 0 0.3 0.7 1.2 2.2 2.9 4.7 6.9 6.7 7 9 8.9 7.8 10.8 7.1 2.5 4.8 4 3.5 3.9 3.6 0 0.7 0.8 PREVAILING DIRECTION BY HOUR Month 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 ALL 110 110 110 100 110 100 100 100 90 90 110 110 100 100 110 100 120 100 100 110 100 100 110 100 1 90 100 100 100 100 110 120 110 100 120 120 120 40 40 80 80 120 80 110 90 120 110 90 110 2 90 90 90 110 90 100 100 50 90 100 100 100 100 90 50 50 110 100 90 90 90 100 100 90 3 120 120 110 110 110 110 110 50 140 100 140 140 100 110 140 70 110 110 110 110 110 110 110 110 4 110 110 140 100 100 110 120 120 120 120 120 100 100 100 100 100 100 100 100 100 100 100 100 100 5 110 200 110 200 110 110 110 200 110 110 110 110 200 110 110 200 200 100 200 90 200 200 200 100 6 270 110 270 70 90 260 270 100 270 90 270 90 90 90 280 90 90 90 90 100 270 90 280 280 7 100 100 100 90 90 80 90 80 90 90 100 100 100 100 100 100 90 270 100 100 100 90 90 100 8 190 190 190 120 120 190 190 190 190 290 270 100 190 270 190 270 280 270 100 280 270 270 270 270 9 110 110 140 290 110 140 140 140 140 100 140 80 110 110 110 110 140 110 140 140 140 140 140 110 10 90 80 90 140 120 120 80 90 110 80 90 80 80 80 80 90 140 80 80 80 80 80 100 100 11 150 50 50 140 50 90 130 140 90 140 140 90 50 40 140 140 140 120 140 50 140 40 120 120 12 140 140 100 140 100 100 100 110 100 100 100 140 270 100 140 90 190 120 110 110 120 120 110 140 SPEED FOR PREVAILING DIRECTION BY HOUR Month 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 ALL 7.54 7.56 7.95 8 8.18 7.71 8.07 7.84 7.04 6.55 7.9 8.34 7.98 7.61 8.44 7.59 7.57 7.65 7.19 7.54 7.67 8.44 7.78 7.95 1 7.42 10.25 11.84 11.95 7.6 10.53 9.77 10.85 5.26 8.47 9.99 9.69 3.88 3.84 6.33 5.46 9.56 4.08 7.74 8.25 8.96 10.4 6.96 8.08 2 10.55 10.36 9.12 11.05 9.61 11.96 10.87 6.81 8.53 9.47 8.31 10.65 10.71 9.85 8.7 7.3 11.1 10.43 8.7 6.97 11.37 10.31 9.58 10.5 3 7.25 7.06 9.82 8.51 8.08 8.27 8.87 5.47 6.35 7.1 7.11 5.21 7.62 10.42 7.21 7.04 7.64 8.29 6.08 8.33 7.42 8.87 8.86 9.57 4 7.28 8.27 7.1 7.77 5.9 6.65 7.55 7.25 8.18 7.95 7.8 7.15 7.92 7.93 8.13 9.32 9.66 8.62 10.01 9.4 9.95 11.37 11.12 9.12 5 8.25 6.25 9 5.77 9.15 8.23 8.26 6.33 9.25 8.23 9.05 9.14 6.87 9.37 7.51 6.72 6.82 7.55 7.02 6.24 7.4 7.01 6.81 6.98 6 4.69 3.67 3.52 3.19 5.05 5.1 3.42 6.29 4.51 4.75 5.15 4.46 5.61 5.55 5.14 6.33 5.35 5.96 5.2 5.33 4.31 5.16 3.08 4.02 7 4.06 4.23 4.42 4.73 4.78 4 3.98 4.68 4.94 5.07 5.52 5.37 5.74 5.33 5.64 4.95 4.76 5.61 4 4.67 4.17 3.19 3.46 4.99 8 4.21 4.42 4.84 4.68 4.6 4.67 4.68 4.92 5.26 3.86 4.37 6.12 5.65 4.55 6.14 3.63 5.12 3.79 5.25 5.15 4.06 3.93 4.33 5.48 9 5.95 6.1 7.15 4.35 7.45 6.01 7.76 7.32 8.01 7.9 8.06 6.6 9.45 8.06 7.87 8.78 6.92 8.06 6.91 7.09 7.91 6.96 7.18 6.8 10 7.81 8.02 8.46 5.53 8.79 9.61 7.77 6.92 6.36 11.38 8.53 10.48 11.18 10.37 13.07 8.31 8.58 7.64 8.92 9.26 9.81 8.9 8.09 8.46 11 5.32 3.82 3.88 8.88 6.72 7.48 6.42 9.15 5.16 9.79 8.99 6.72 5.91 3.73 8.01 11.35 8.8 10.08 9.5 6.85 7.32 6.45 9.46 8.96 12 7.89 7.1 11.96 10.29 13.21 12.59 11.27 9.85 13.46 11.86 11.97 9.22 6.26 12.16 9.89 9.71 5.01 11.72 9.29 10.23 11.2 10.98 11.2 7.54