Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Palmer(UAF)_raw-data
SDR 5.7.6 -----Logger Information----- Model # Serial # 2402 Hardware Rev. 009-008-000 -----Site Information----- Site # 1402 Site Desc Palmer UAF Project Code Project Desc Site Location Site Elevation 63 Latitude N 061° 33.973' Longitude W 149° 14.384' Time offset (hrs) -9 -----Sensor Information----- Channel # 1 Type 1 Description NRG #40 Anem. m/s Details Serial Number SN: Height 30 m Scale Factor 0.765 Offset 0.35 Units m/s Channel # 2 Type 1 Description NRG #40 Anem. m/s Details Serial Number SN: Height 30 m Scale Factor 0.765 Offset 0.35 Units m/s Channel # 3 Type 1 Description NRG #40 Anem. m/s Details Serial Number SN: Height 20 m Scale Factor 0.765 Offset 0.35 Units m/s Channel # 4 Type 0 Description No SCM Installed Details Serial Number -------- Height ------ Scale Factor 0 Offset 0 Units ----- Channel # 5 Type 0 Description No SCM Installed Details Serial Number -------- Height ------ Scale Factor 0 Offset 0 Units ----- Channel # 6 Type 0 Description No SCM Installed Details Serial Number -------- Height ------ Scale Factor 0 Offset 0 Units ----- Channel # 7 Type 3 Description #200P Wind Vane Details Serial Number SN: Height 30 m Scale Factor 0.351 Offset 300 Units deg Channel # 8 Type 0 Description No Sensor Details Serial Number SN: Height m Scale Factor 0 Offset 0 Units Channel # 9 Type 4 Description NRG #110S Temp C Details Serial Number SN: Height 0 Scale Factor 0.138 Offset -86.381 Units C Channel # 10 Type 0 Description No SCM Installed Details Serial Number -------- Height ------ Scale Factor 0 Offset 0 Units ----- Channel # 11 Type 0 Description No SCM Installed Details Serial Number -------- Height ------ Scale Factor 0 Offset 0 Units ----- Channel # 12 Type 0 Description No SCM Installed Details Serial Number -------- Height ------ Scale Factor 0 Offset 0 Units ----- Date & Time Stamp CH1Avg CH1SD CH1Max CH1Min CH2Avg CH2SD CH2Max CH2Min CH3Avg CH3SD CH3Max CH3Min CH4Avg CH4SD CH4Max CH4Min CH5Avg CH5SD CH5Max CH5Min CH6Avg CH6SD CH6Max CH6Min CH7Avg CH7SD CH7Max CH7Min CH8Avg CH8SD CH8Max CH8Min CH9Avg CH9SD CH9Max CH9Min CH10Avg CH10SD CH10Max CH10Min CH11Avg CH11SD CH11Max CH11Min CH12Avg CH12SD CH12Max CH12Min 10/30/2005 00:00:00 3.8 0.8 6.1 1.9 3.8 0.9 6.1 1.5 2.7 0.9 5.3 0.7 49 13 63 300 -3 0.1 -2.8 -3.3 10/30/2005 00:10:00 3.8 0.9 6.1 1.1 3.7 1 6.1 1.1 3 1 5.3 1.1 50 13 40 300 -2.9 0 -2.8 -3 10/30/2005 00:20:00 3.4 0.8 5.3 1.1 3.3 0.9 5.3 0.4 2.5 0.8 5.3 0.7 60 15 68 300 -2.8 0 -2.6 -2.8 10/30/2005 00:30:00 3 0.8 5.3 1.5 2.9 0.8 5.3 0.7 2.3 0.7 4.6 0.4 60 19 57 300 -2.8 0 -2.8 -2.8 10/30/2005 00:40:00 3.7 1 6.1 1.5 3.5 1 5.7 1.1 3 0.8 5.3 1.1 50 20 54 300 -2.8 0 -2.6 -2.8 10/30/2005 00:50:00 4.4 1 6.8 1.1 4.1 1 6.5 0.4 3.1 0.8 5.7 1.1 43 17 40 300 -2.8 0 -2.6 -2.8 10/30/2005 01:00:00 4.1 1.2 7.6 1.5 3.9 1.3 7.6 1.1 3.1 1 6.5 0.7 47 17 40 300 -2.6 0 -2.6 -2.8 10/30/2005 01:10:00 5.3 1.2 8.8 2.3 5.1 1.3 8.8 2.3 3.9 1.2 8.8 1.5 52 15 54 300 -2.5 0.1 -2.4 -2.6 10/30/2005 01:20:00 3.7 1.2 8 1.5 3.5 1.3 8 0.7 2.6 1.1 5.7 0.7 53 20 48 300 -2.5 0 -2.4 -2.6 10/30/2005 01:30:00 2.3 0.8 4.6 0.4 2.1 0.9 4.6 0.4 1.9 0.8 4.6 0.4 66 22 39 300 -2.4 0 -2.1 -2.6 10/30/2005 01:40:00 2.5 0.7 3.8 0.7 2.3 0.8 3.8 0.4 2 0.8 4.2 0.4 71 21 80 300 -2.5 0 -2.1 -2.6 10/30/2005 01:50:00 1.5 0.6 3.4 0.4 1.2 0.6 3.4 0.4 1.4 0.5 2.6 0.4 130 58 41 300 -3.1 0.3 -2.6 -3.5 10/30/2005 02:00:00 0.8 0.5 2.6 0.4 0.7 0.5 3 0.4 0.6 0.3 1.9 0.4 107 49 38 300 -3.6 0 -3.5 -3.7 10/30/2005 02:10:00 2.1 1 4.6 0.4 1.8 1.1 4.6 0.4 1.6 0.9 4.9 0.4 61 30 43 300 -3.3 0.3 -2.6 -3.5 10/30/2005 02:20:00 3.6 0.8 6.5 1.9 3.5 0.9 6.1 1.1 3 0.8 5.3 1.1 48 15 49 300 -2.5 0.1 -2.1 -2.8 10/30/2005 02:30:00 3.4 0.8 4.9 1.1 3.3 0.8 5.3 1.1 2.6 0.8 4.9 1.1 46 17 42 300 -2.4 0 -2.1 -2.4 10/30/2005 02:40:00 2.9 0.7 4.6 1.1 2.7 0.7 4.9 0.7 2.2 0.7 4.2 0.4 46 14 51 300 -2.4 0 -2.1 -2.4 10/30/2005 02:50:00 1.6 0.4 2.6 0.4 1.3 0.5 2.6 0.4 1.3 0.4 2.3 0.4 72 19 48 300 -2.5 0.1 -2.1 -2.6 10/30/2005 03:00:00 1.5 0.4 2.3 0.7 1.1 0.4 1.9 0.4 1.2 0.3 1.9 0.4 89 7 95 300 -2.6 0 -2.6 -2.8 10/30/2005 03:10:00 1.1 0.4 2.3 0.4 0.7 0.4 2.3 0.4 0.8 0.4 1.9 0.4 95 7 95 300 -2.6 0 -2.6 -2.8 10/30/2005 03:20:00 1.2 0.3 1.9 0.4 0.7 0.3 1.5 0.4 0.8 0.3 1.5 0.4 83 8 83 300 -2.6 0 -2.6 -2.8 10/30/2005 03:30:00 1.3 0.5 2.6 0.4 1 0.5 2.3 0.4 1.1 0.6 2.3 0.4 63 15 51 300 -2.6 0 -2.6 -2.8 10/30/2005 03:40:00 1.5 0.6 3 0.4 1.2 0.7 2.6 0.4 1.3 0.5 2.6 0.4 68 15 71 300 -2.5 0 -2.4 -2.6 10/30/2005 03:50:00 1.8 1 4.2 0.4 1.5 1.1 4.2 0.4 1.4 0.7 3.4 0.4 44 15 36 300 -2.4 0 -2.4 -2.6 10/30/2005 04:00:00 2.4 0.8 3.8 0.4 2.2 0.9 4.2 0.4 1.9 0.8 3.8 0.4 54 15 50 300 -2.4 0 -2.1 -2.6 10/30/2005 04:10:00 2.1 0.8 4.2 0.7 1.9 1 4.2 0.4 1.9 0.8 3.8 0.4 58 14 46 300 -2.4 0 -2.1 -2.6 10/30/2005 04:20:00 1.7 0.5 2.6 0.4 1.5 0.5 3 0.4 1.5 0.5 3 0.4 70 18 83 300 -2.4 0 -2.4 -2.6 10/30/2005 04:30:00 2 0.5 3.4 1.1 1.8 0.6 3.4 0.4 1.6 0.4 2.6 0.7 81 11 80 300 -2.5 0 -2.4 -2.6 10/30/2005 04:40:00 1.3 0.7 2.6 0.4 1 0.7 2.6 0.4 1.1 0.6 2.3 0.4 80 17 85 300 -2.6 0 -2.4 -2.6 10/30/2005 04:50:00 0.9 0.5 1.9 0.4 0.6 0.4 1.9 0.4 0.6 0.4 1.9 0.4 71 18 113 300 -2.6 0 -2.6 -2.6 10/30/2005 05:00:00 1.6 0.4 2.6 0.4 1.2 0.5 2.3 0.4 1.1 0.5 2.3 0.4 39 12 47 300 -2.5 0 -2.4 -2.6 10/30/2005 05:10:00 2.2 0.4 3 1.5 1.9 0.5 3 0.7 1.5 0.5 2.6 0.4 36 8 53 300 -2.5 0 -2.4 -2.6 10/30/2005 05:20:00 2.2 0.3 3 1.5 2 0.4 3 0.7 1.6 0.4 2.6 0.7 45 8 45 300 -2.6 0 -2.6 -2.6 10/30/2005 05:30:00 1.5 0.4 2.6 0.7 1.1 0.5 2.3 0.4 1.2 0.4 1.9 0.4 68 11 57 300 -2.6 0 -2.6 -2.6 10/30/2005 05:40:00 1.5 0.3 2.3 0.7 1.2 0.4 1.9 0.4 1.4 0.4 2.3 0.4 76 6 76 300 -2.7 0 -2.6 -2.8 10/30/2005 05:50:00 1.8 0.5 2.6 0.4 1.5 0.5 2.6 0.4 1.5 0.5 2.6 0.4 60 13 70 300 -2.9 0 -2.8 -2.8 10/30/2005 06:00:00 1.2 0.5 2.6 0.4 0.8 0.5 2.6 0.4 0.9 0.5 2.6 0.4 53 13 45 300 -2.9 0 -2.8 -3 10/30/2005 06:10:00 0.7 0.4 1.9 0.4 0.5 0.3 1.5 0.4 0.7 0.3 1.5 0.4 51 17 62 300 -2.9 0 -2.8 -3 10/30/2005 06:20:00 1.5 0.5 2.6 0.4 1.2 0.6 2.3 0.4 1.1 0.5 2.3 0.4 46 12 51 300 -2.9 0 -2.8 -2.8 10/30/2005 06:30:00 0.8 0.4 1.9 0.4 0.5 0.3 1.5 0.4 0.5 0.3 1.5 0.4 48 9 43 300 -2.9 0 -2.8 -2.8 10/30/2005 06:40:00 0.6 0.3 1.5 0.4 0.4 0.1 0.7 0.4 0.5 0.2 1.1 0.4 66 12 73 300 -2.8 0 -2.6 -2.8 10/30/2005 06:50:00 1.1 0.3 1.9 0.4 0.6 0.3 1.5 0.4 0.9 0.3 1.5 0.4 70 7 68 300 -2.7 0 -2.6 -2.8 10/30/2005 07:00:00 1.6 0.4 2.6 0.7 1.2 0.4 2.3 0.4 1.3 0.4 2.3 0.4 71 9 74 300 -2.6 0 -2.6 -2.8 10/30/2005 07:10:00 1.7 0.4 2.6 0.7 1.4 0.4 2.6 0.4 1.6 0.4 2.6 0.4 65 9 68 300 -2.6 0 -2.6 -2.8 10/30/2005 07:20:00 0.9 0.5 2.3 0.4 0.7 0.5 2.3 0.4 0.8 0.5 2.3 0.4 68 15 66 300 -2.6 0 -2.6 -2.6 10/30/2005 07:30:00 1.1 0.3 1.9 0.4 0.6 0.3 1.5 0.4 1 0.4 1.5 0.4 76 8 57 300 -2.6 0 -2.6 -2.6 10/30/2005 07:40:00 0.9 0.4 1.5 0.4 0.5 0.2 1.1 0.4 0.8 0.4 1.9 0.4 83 3 78 300 -2.6 0 -2.6 -2.6 10/30/2005 07:50:00 0.6 0.3 1.1 0.4 0.4 0 0.7 0.4 0.5 0.2 1.1 0.4 85 0 84 300 -2.6 0 -2.6 -2.6 10/30/2005 08:00:00 0.6 0.2 1.1 0.4 0.4 0 0.4 0.4 0.5 0.2 1.1 0.4 84 1 85 300 -2.6 0 -2.6 -2.8 10/30/2005 08:10:00 0.7 0.3 1.1 0.4 0.4 0 0.7 0.4 0.6 0.3 1.1 0.4 84 1 85 300 -2.7 0 -2.6 -2.8 10/30/2005 08:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 85 1 300 300 -2.8 0 -2.6 -2.8 10/30/2005 08:30:00 0.5 0.3 1.5 0.4 0.4 0.1 1.1 0.4 0.4 0.1 0.7 0.4 102 29 158 300 -2.9 0 -2.8 -3 10/30/2005 08:40:00 1 0.2 1.5 0.4 0.5 0.2 1.1 0.4 0.7 0.2 1.1 0.4 169 10 158 300 -3 0 -2.8 -3.3 10/30/2005 08:50:00 1 0.3 1.9 0.4 0.7 0.3 1.5 0.4 1.1 0.3 1.5 0.4 194 7 188 300 -3.1 0 -3 -3.3 10/30/2005 09:00:00 0.9 0.3 1.5 0.4 0.5 0.2 1.1 0.4 1 0.2 1.5 0.4 196 5 200 300 -3.2 0 -2.8 -3.3 10/30/2005 09:10:00 0.7 0.4 1.5 0.4 0.4 0.1 0.7 0.4 0.6 0.4 1.5 0.4 214 2 214 300 -3.3 0 -2.8 -3.5 10/30/2005 09:20:00 0.5 0.2 1.1 0.4 0.4 0 0.4 0.4 0.5 0.3 1.1 0.4 215 0 215 300 -3.3 0 -3.3 -3.5 10/30/2005 09:30:00 0.6 0.2 1.1 0.4 0.4 0 0.4 0.4 0.6 0.2 1.1 0.4 215 0 214 300 -3.3 0 -2.8 -3.5 10/30/2005 09:40:00 0.4 0.1 0.7 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 215 0 211 300 -3.3 0 -3.3 -3.5 10/30/2005 09:50:00 0.5 0.2 1.1 0.4 0.4 0 0.4 0.4 0.5 0.2 1.1 0.4 199 18 199 300 -3 0.1 -2.8 -3.3 10/30/2005 10:00:00 0.8 0.4 1.5 0.4 0.5 0.3 1.5 0.4 0.7 0.4 1.5 0.4 164 15 147 300 -2.5 0.1 -2.1 -2.8 10/30/2005 10:10:00 1.1 0.3 1.5 0.4 0.7 0.3 1.1 0.4 0.9 0.4 1.9 0.4 125 5 133 300 -2.1 0 -1.9 -2.1 10/30/2005 10:20:00 0.5 0.3 1.5 0.4 0.4 0.1 1.1 0.4 0.4 0.2 1.1 0.4 109 7 108 300 -1.8 0 -1.4 -2.1 10/30/2005 10:30:00 0.4 0.1 1.1 0.4 0.4 0 0.4 0.4 0.4 0.1 0.7 0.4 165 9 144 300 -1.4 0.1 -1.2 -1.7 10/30/2005 10:40:00 0.5 0.2 1.9 0.4 0.4 0.1 1.5 0.4 0.5 0.3 1.5 0.4 176 13 191 300 -1.3 0 -1.2 -1.4 10/30/2005 10:50:00 0.8 0.4 1.9 0.4 0.5 0.3 1.5 0.4 0.8 0.4 1.9 0.4 186 9 179 300 -1.7 0 -1.4 -1.9 10/30/2005 11:00:00 1.1 0.3 1.9 0.4 0.7 0.4 1.9 0.4 1 0.4 1.9 0.4 200 12 213 300 -1.8 0 -1.7 -1.9 10/30/2005 11:10:00 0.9 0.4 1.9 0.4 0.6 0.3 1.5 0.4 1 0.4 1.9 0.4 214 11 203 300 -1.7 0 -1.4 -1.9 10/30/2005 11:20:00 1 0.5 1.9 0.4 0.7 0.4 1.9 0.4 0.9 0.5 1.9 0.4 209 8 208 300 -1.6 0 -1.4 -1.7 10/30/2005 11:30:00 0.6 0.3 1.5 0.4 0.4 0.2 1.1 0.4 0.5 0.2 1.5 0.4 209 8 222 300 -1.4 0 -1.2 -1.4 10/30/2005 11:40:00 0.7 0.4 1.5 0.4 0.5 0.2 1.5 0.4 0.6 0.4 1.5 0.4 201 20 168 300 -1.3 0 -1.2 -1.4 10/30/2005 11:50:00 1.1 0.3 1.9 0.4 0.8 0.3 1.5 0.4 1 0.3 1.9 0.4 193 3 191 300 -1.2 0 -1.2 -1.2 10/30/2005 12:00:00 1.1 0.4 2.3 0.4 0.8 0.4 1.9 0.4 1.1 0.4 2.3 0.4 199 11 175 300 -1.2 0 -1 -1.2 10/30/2005 12:10:00 1.4 0.5 2.3 0.4 1.2 0.5 2.3 0.4 1.3 0.5 2.3 0.4 206 12 194 300 -1.1 0 -1 -1.2 10/30/2005 12:20:00 1.5 0.4 2.3 0.4 1.3 0.5 2.3 0.4 1.4 0.5 2.3 0.4 198 14 198 300 -1 0 -0.7 -1.2 10/30/2005 12:30:00 1.3 0.4 2.3 0.4 1.1 0.5 2.3 0.4 1.4 0.4 2.3 0.4 216 13 214 300 -0.9 0 -0.7 -1.2 10/30/2005 12:40:00 1.4 0.5 2.6 0.4 1.2 0.6 2.3 0.4 1.4 0.5 2.3 0.4 214 12 227 300 -0.7 0 -0.5 -0.7 10/30/2005 12:50:00 1.8 0.5 3 0.4 1.7 0.6 3 0.4 1.8 0.5 3 0.7 218 13 219 300 -0.5 0 -0.5 -0.7 10/30/2005 13:00:00 2 0.5 3.4 0.4 2 0.6 3.4 0.4 2.1 0.5 3 0.7 204 15 187 300 -0.5 0 -0.5 -0.5 10/30/2005 13:10:00 1.9 0.6 3 0.4 1.9 0.6 3 0.4 1.9 0.6 3 0.4 198 11 187 300 -0.5 0 -0.3 -0.5 10/30/2005 13:20:00 1.5 0.5 2.6 0.4 1.3 0.5 3 0.4 1.6 0.4 2.6 0.4 211 18 222 300 -0.1 0 0.2 -0.3 10/30/2005 13:30:00 2 0.6 3.4 0.7 1.8 0.7 3 0.4 1.9 0.6 3.4 0.4 201 17 196 300 0.1 0 0.4 -0.1 10/30/2005 13:40:00 2.1 0.5 3.4 0.7 2 0.6 3.4 0.4 1.9 0.6 3 0.4 219 13 225 300 -0.3 0.1 -0.1 -0.5 10/30/2005 13:50:00 2.1 0.6 3.4 0.7 2 0.6 3 0.4 2 0.5 3 0.7 219 12 217 300 -0.3 0 -0.1 -0.5 10/30/2005 14:00:00 2 0.5 3 0.7 1.9 0.5 3 0.4 1.9 0.5 3 0.7 219 11 207 300 -0.2 0.1 0.2 -0.3 10/30/2005 14:10:00 2 0.4 3 0.7 2 0.5 3 0.4 1.8 0.5 3 0.7 215 12 220 300 -0.2 0 0.2 -0.5 10/30/2005 14:20:00 1.6 0.5 2.6 0.4 1.6 0.6 2.6 0.4 1.6 0.5 2.6 0.4 204 15 225 300 0.5 0.3 0.9 -0.1 10/30/2005 14:30:00 1.7 0.5 3 0.4 1.6 0.5 2.6 0.4 1.7 0.5 3 0.4 216 15 248 300 1.1 0 1.4 0.9 10/30/2005 14:40:00 1.6 0.5 2.6 0.4 1.4 0.5 2.6 0.4 1.5 0.5 2.6 0.4 230 16 217 300 1.3 0 1.6 1.1 10/30/2005 14:50:00 1.5 0.4 2.6 0.4 1.1 0.5 2.3 0.4 1.3 0.5 2.3 0.4 239 11 231 300 1.4 0 1.6 1.4 10/30/2005 15:00:00 0.9 0.5 1.9 0.4 0.7 0.4 1.9 0.4 0.8 0.4 2.3 0.4 206 28 216 300 1.8 0.1 2.3 1.4 10/30/2005 15:10:00 0.9 0.4 1.9 0.4 0.6 0.3 1.5 0.4 0.9 0.4 1.9 0.4 192 16 153 300 1.8 0.1 2.3 1.6 10/30/2005 15:20:00 0.8 0.5 2.3 0.4 0.6 0.4 1.9 0.4 0.7 0.4 1.9 0.4 202 27 172 300 2 0 2.3 1.8 10/30/2005 15:30:00 1.4 0.3 2.3 0.4 1.2 0.4 1.9 0.4 1.4 0.3 1.9 0.7 190 11 197 300 1.5 0.1 1.8 1.4 10/30/2005 15:40:00 1.2 0.4 1.9 0.4 1 0.4 1.9 0.4 1.2 0.4 1.9 0.4 197 15 236 300 1.3 0 1.4 1.4 10/30/2005 15:50:00 1.7 0.6 3.4 0.4 1.6 0.7 3 0.4 1.5 0.6 3 0.4 214 13 220 300 1.1 0.1 1.4 0.9 10/30/2005 16:00:00 2.3 0.5 3.4 1.1 2.3 0.4 3.4 1.1 1.9 0.5 3.4 0.4 217 9 223 300 0.7 0 0.9 0.4 10/30/2005 16:10:00 2 0.4 2.6 0.7 1.9 0.5 3.4 0.4 1.8 0.5 3 0.4 221 10 219 300 0.2 0 0.4 0.2 10/30/2005 16:20:00 1.7 0.6 2.6 0.4 1.6 0.6 2.6 0.4 1.3 0.5 2.6 0.4 224 9 241 300 0 0 0.2 -0.3 10/30/2005 16:30:00 1.1 0.4 1.9 0.4 0.8 0.4 1.9 0.4 0.7 0.3 1.5 0.4 218 7 221 300 -0.5 0 -0.1 -0.7 10/30/2005 16:40:00 1.3 0.3 1.9 0.4 0.9 0.3 1.5 0.4 0.9 0.3 1.5 0.4 231 7 230 300 -0.7 0 -0.5 -0.7 10/30/2005 16:50:00 1 0.3 1.5 0.4 0.8 0.4 1.9 0.4 1.1 0.2 1.9 0.4 212 6 220 300 -0.9 0 -0.7 -1 10/30/2005 17:00:00 0.9 0.5 1.9 0.4 0.9 0.7 2.3 0.4 1 0.6 2.3 0.4 207 1 208 300 -1.2 0.1 -1 -1.4 10/30/2005 17:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 206 0 300 300 -1.6 0 -1.4 -1.7 10/30/2005 17:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 206 0 300 300 -1.6 0 -1.4 -1.9 10/30/2005 17:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 206 0 300 300 -2 0 -1.9 -2.1 10/30/2005 17:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 206 0 300 300 -2.1 0 -2.1 -2.1 10/30/2005 17:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 206 0 300 300 -2.5 0.1 -2.1 -2.6 10/30/2005 18:00:00 0.4 0.1 1.1 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 181 10 177 300 -2.6 0 -2.6 -2.8 10/30/2005 18:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 177 0 300 300 -2.9 0.1 -2.6 -3.3 10/30/2005 18:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 177 0 300 300 -3.2 0 -2.6 -3.3 10/30/2005 18:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.5 0.2 1.1 0.4 196 30 300 300 -3.4 0.1 -3.3 -3.7 10/30/2005 18:40:00 0.4 0.2 1.1 0.4 0.4 0 0.4 0.4 0.9 0.2 1.5 0.4 264 17 295 300 -3.5 0 -3.3 -3.7 10/30/2005 18:50:00 0.4 0.2 0.7 0.4 0.4 0 0.4 0.4 0.6 0.3 1.5 0.4 299 0 299 300 -3.6 0.1 -3.3 -3.7 10/30/2005 19:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 299 0 300 300 -3.9 0 -3.7 -4.2 10/30/2005 19:10:00 0.4 0.2 1.1 0.4 0.4 0 0.4 0.4 0.5 0.3 1.1 0.4 327 41 34 300 -4.3 0 -3.9 -4.6 10/30/2005 19:20:00 0.9 0.5 1.9 0.4 0.6 0.4 1.9 0.4 1.1 0.4 1.9 0.4 48 15 66 300 -4.4 0 -4.4 -4.6 10/30/2005 19:30:00 2.2 0.3 2.6 1.5 2 0.4 2.6 1.1 1.9 0.2 2.3 1.5 63 4 61 300 -4.4 0 -4.4 -4.6 10/30/2005 19:40:00 2.4 0.2 2.6 1.9 2.2 0.2 2.6 1.9 1.9 0.3 2.6 1.1 49 7 56 300 -4.3 0 -4.2 -4.6 10/30/2005 19:50:00 2.8 0.2 3.4 2.3 2.7 0.2 3 2.3 1.8 0.3 2.3 1.1 33 2 29 300 -4.5 0 -4.2 -4.6 10/30/2005 20:00:00 2.8 0.2 3 2.3 2.7 0.2 3 2.3 1.7 0.3 2.3 0.7 31 3 29 300 -4.3 0 -4.2 -4.4 10/30/2005 20:10:00 2.8 0.2 3 2.6 2.7 0.2 3 1.9 1.8 0.3 2.3 1.1 34 1 30 300 -4.3 0 -4.2 -4.6 10/30/2005 20:20:00 3.1 0.4 4.2 2.3 2.9 0.4 3.8 1.9 1.9 0.4 3 0.7 37 5 30 300 -4.8 0 -4.4 -4.8 10/30/2005 20:30:00 3.3 0.4 4.6 2.3 3.2 0.5 4.2 1.9 2.1 0.4 3.4 1.1 38 6 33 300 -4.8 0 -4.6 -5 10/30/2005 20:40:00 2.9 0.3 3.8 1.9 2.8 0.4 3.8 1.9 2.1 0.4 3 1.1 46 7 46 300 -4.3 0.3 -3.7 -5 10/30/2005 20:50:00 2.9 0.3 3.8 1.9 2.8 0.4 3.8 1.9 2.3 0.4 3.4 1.1 52 7 60 300 -4.2 0.1 -3.9 -4.4 10/30/2005 21:00:00 3.3 0.3 4.2 2.6 3.3 0.4 4.2 2.6 2.7 0.4 3.4 1.9 66 3 64 300 -4.4 0 -4.4 -4.6 10/30/2005 21:10:00 2.9 0.3 3.8 2.3 2.8 0.3 4.2 2.3 2.5 0.2 3 1.9 72 5 66 300 -4.4 0.3 -3.9 -4.8 10/30/2005 21:20:00 2.7 0.4 3.8 1.9 2.6 0.5 3.8 1.5 2.3 0.4 3.4 1.5 58 7 62 300 -4.2 0 -3.9 -4.4 10/30/2005 21:30:00 2.4 0.3 3 1.9 2.2 0.3 3 1.5 1.8 0.4 2.6 0.7 49 4 38 300 -3.9 0 -3.7 -4.2 10/30/2005 21:40:00 2.4 0.2 2.6 1.9 2.2 0.2 2.6 1.9 1.8 0.3 2.3 0.7 53 5 49 300 -3.8 0 -3.5 -3.9 10/30/2005 21:50:00 2 0.2 2.6 1.5 1.8 0.2 2.3 1.5 1.5 0.2 1.9 1.1 51 5 48 300 -4.3 0 -3.9 -4.6 10/30/2005 22:00:00 2.3 0.3 3 1.5 2.1 0.3 2.6 1.1 1.5 0.3 2.3 0.7 40 4 39 300 -4.4 0 -3.9 -4.6 10/30/2005 22:10:00 2.6 0.3 3.4 2.3 2.5 0.3 3.4 1.9 1.9 0.3 3 1.5 46 4 51 300 -4.8 0 -4.2 -5 10/30/2005 22:20:00 3.3 0.3 4.2 2.6 3.3 0.3 4.2 2.6 2.5 0.3 3.4 1.5 49 3 46 300 -5 0 -4.8 -5.3 10/30/2005 22:30:00 2.6 0.3 3.4 1.9 2.5 0.3 3.4 1.9 1.7 0.5 2.6 0.7 44 5 49 300 -5.1 0.1 -4.8 -5.3 10/30/2005 22:40:00 1.4 0.5 2.3 0.4 1.1 0.5 2.3 0.4 0.7 0.4 1.5 0.4 38 0 37 300 -4.8 0 -4.6 -5 10/30/2005 22:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 38 0 300 300 -4.8 0.1 -4.4 -5 10/30/2005 23:00:00 0.4 0.1 0.7 0.4 0.4 0 0.4 0.4 0.4 0.1 1.1 0.4 319 36 334 300 -5.4 0 -5 -5.5 10/30/2005 23:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0.1 1.1 0.4 298 5 300 300 -5.8 0.1 -5.5 -6.1 10/30/2005 23:20:00 0.4 0.1 1.1 0.4 0.4 0 0.4 0.4 0.5 0.3 1.5 0.4 218 3 218 300 -6.1 0 -5.9 -6.1 10/30/2005 23:30:00 1 0.4 1.5 0.4 0.6 0.3 1.1 0.4 1.3 0.2 1.5 0.7 235 10 227 300 -6.3 0 -6.1 -6.4 10/30/2005 23:40:00 0.5 0.3 1.1 0.4 0.4 0.1 0.7 0.4 0.9 0.3 1.1 0.4 245 0 246 300 -6 0.2 -5.5 -6.4 10/30/2005 23:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0.1 0.7 0.4 245 0 300 300 -6.1 0.3 -5 -6.6 10/31/2005 00:00:00 0.4 0.2 1.1 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 280 45 338 300 -6.6 0 -6.4 -7 10/31/2005 00:10:00 1.9 0.5 2.6 0.4 1.6 0.6 2.6 0.4 1.1 0.6 2.3 0.4 38 10 45 300 -6.6 0.2 -6.1 -6.8 10/31/2005 00:20:00 2.4 0.2 3 1.9 2.3 0.3 3 1.9 2.1 0.2 2.6 1.9 49 4 55 300 -6.1 0 -5.9 -6.4 10/31/2005 00:30:00 2.5 0.3 3.4 1.9 2.3 0.4 3.4 1.5 1.6 0.4 3 0.7 39 4 48 300 -6.1 0 -5.9 -6.1 10/31/2005 00:40:00 2.2 0.3 3 1.5 1.8 0.4 2.6 1.1 1.2 0.3 2.6 0.7 21 8 19 300 -6.4 0 -6.1 -6.6 10/31/2005 00:50:00 2.7 0.3 3.4 1.9 2.4 0.3 3.4 1.9 1.6 0.4 2.6 0.7 19 6 25 300 -6.2 0 -5.9 -6.4 10/31/2005 01:00:00 2.7 0.3 3.4 1.9 2.2 0.4 3.4 1.5 1.5 0.3 2.3 0.7 27 5 31 300 -6.7 0.2 -6.1 -7 10/31/2005 01:10:00 2 0.3 3 1.1 1.7 0.4 2.6 0.4 0.8 0.3 1.5 0.4 36 7 39 300 -6.5 0.4 -5.9 -7 10/31/2005 01:20:00 2.1 0.3 3 1.5 1.9 0.4 3 0.7 1.2 0.3 1.9 0.4 39 5 35 300 -6.2 0.1 -5.7 -6.6 10/31/2005 01:30:00 2.8 0.3 3.4 1.9 2.6 0.4 3.4 1.5 1.9 0.4 3 1.1 39 5 40 300 -5.9 0.1 -5.5 -6.1 10/31/2005 01:40:00 1.7 0.6 3 0.4 1.2 0.7 2.6 0.4 0.8 0.5 2.3 0.4 33 7 35 300 -5.9 0.1 -5.5 -6.1 10/31/2005 01:50:00 0.4 0.2 1.1 0.4 0.4 0.1 1.5 0.4 0.4 0.2 1.1 0.4 62 7 65 300 -5.2 0.1 -4.8 -5.5 10/31/2005 02:00:00 0.7 0.4 1.9 0.4 0.4 0.2 1.5 0.4 0.4 0 0.4 0.4 49 21 44 300 -5.5 0.2 -5 -5.7 10/31/2005 02:10:00 0.5 0.3 1.5 0.4 0.4 0.1 1.1 0.4 0.4 0 0.4 0.4 40 3 37 300 -5.8 0 -5.7 -5.9 10/31/2005 02:20:00 0.4 0.2 1.1 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 45 1 45 300 -5.8 0 -5.7 -5.9 10/31/2005 02:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.5 0.2 1.1 0.4 46 1 300 300 -6 0 -5.7 -5.9 10/31/2005 02:40:00 0.5 0.2 1.1 0.4 0.4 0 0.4 0.4 0.9 0.4 1.9 0.4 274 27 268 300 -5.9 0 -5.7 -5.9 10/31/2005 02:50:00 0.4 0 0.7 0.4 0.4 0 0.4 0.4 0.6 0.3 1.5 0.4 268 1 268 300 -6.5 0.2 -5.7 -7 10/31/2005 03:00:00 0.4 0.1 0.7 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 268 0 268 300 -6.8 0.1 -6.6 -7 10/31/2005 03:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 268 0 300 300 -7.1 0 -6.8 -7 10/31/2005 03:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 268 0 300 300 -7.1 0 -6.8 -7.2 10/31/2005 03:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0.1 0.7 0.4 268 0 300 300 -7.3 0 -7 -7.4 10/31/2005 03:40:00 0.8 0.5 1.9 0.4 0.6 0.3 1.5 0.4 0.5 0.3 1.5 0.4 345 82 63 300 -7.3 0 -7 -7.4 10/31/2005 03:50:00 1.6 0.3 2.3 1.1 1.3 0.3 1.9 0.4 1.2 0.3 1.9 0.4 70 9 75 300 -7.4 0.2 -7 -7.6 10/31/2005 04:00:00 2.1 0.4 3 1.1 1.9 0.5 3 1.1 2.3 0.8 3.8 0.7 54 9 64 300 -7.6 0 -7.2 -7.6 10/31/2005 04:10:00 2.9 0.3 3.4 2.3 2.8 0.3 3.4 1.9 2.6 0.5 3.4 1.1 61 4 58 300 -7.6 0 -7.2 -7.6 10/31/2005 04:20:00 2.4 0.5 3 1.1 2.2 0.5 3 0.7 1.6 0.4 2.6 0.7 64 5 72 300 -7.5 0 -7.2 -7.6 10/31/2005 04:30:00 2.7 0.2 3 2.3 2.6 0.3 3 2.3 2.2 0.2 2.6 1.5 56 5 59 300 -7.8 0.1 -7.4 -8.1 10/31/2005 04:40:00 3.1 0.2 3.4 2.6 3.1 0.2 3.4 2.6 2.7 0.2 3 2.3 62 2 61 300 -7.4 0.1 -7 -7.6 10/31/2005 04:50:00 2.9 0.2 3.4 2.6 2.9 0.2 3 2.6 2.6 0.2 3 2.3 61 3 66 300 -7.3 0.2 -6.8 -7.6 10/31/2005 05:00:00 2.3 0.3 3 1.5 2.1 0.4 3 1.5 2.4 0.2 2.6 1.5 63 5 57 300 -6.6 0 -6.6 -7 10/31/2005 05:10:00 2.1 0.2 2.6 1.9 1.9 0.2 2.3 1.5 2 0.2 2.3 1.5 72 3 69 300 -6.9 0.1 -6.6 -7.2 10/31/2005 05:20:00 2 0.3 2.6 1.5 1.8 0.3 2.3 1.1 1.9 0.3 2.3 0.7 75 12 82 300 -7.5 0.1 -7 -7.6 10/31/2005 05:30:00 0.8 0.4 1.5 0.4 0.5 0.2 1.5 0.4 1 0.4 1.9 0.4 60 10 42 300 -7.6 0.1 -7 -7.9 10/31/2005 05:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0.1 1.1 0.4 136 33 300 300 -7.4 0.3 -7 -8.1 10/31/2005 05:50:00 0.4 0 0.7 0.4 0.4 0 0.4 0.4 0.4 0 0.7 0.4 162 1 162 300 -8.3 0.2 -7.9 -8.7 10/31/2005 06:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.7 0.4 162 1 300 300 -8.4 0 -8.3 -8.5 10/31/2005 06:10:00 0.4 0.1 1.1 0.4 0.4 0 0.4 0.4 1 0.5 1.9 0.4 160 6 147 300 -8.4 0 -8.3 -8.5 10/31/2005 06:20:00 0.4 0.1 0.7 0.4 0.4 0 0.4 0.4 0.7 0.4 1.5 0.4 147 0 147 300 -8.2 0 -8.1 -8.5 10/31/2005 06:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0.1 1.1 0.4 147 0 300 300 -8.2 0 -7.9 -8.3 10/31/2005 06:40:00 0.4 0 0.7 0.4 0.4 0 0.4 0.4 0.4 0.2 1.1 0.4 180 33 216 300 -8.2 0 -8.1 -8.3 10/31/2005 06:50:00 0.7 0.3 1.1 0.4 0.4 0.1 0.7 0.4 0.4 0 0.4 0.4 226 5 228 300 -7.8 0.1 -7.6 -8.1 10/31/2005 07:00:00 0.9 0.2 1.1 0.4 0.5 0.2 0.7 0.4 0.4 0.1 0.7 0.4 228 0 228 300 -8.1 0 -7.6 -8.3 10/31/2005 07:10:00 1.2 0.2 1.9 0.7 1 0.3 1.9 0.4 0.9 0.3 1.5 0.4 218 9 206 300 -8.3 0 -8.1 -8.5 10/31/2005 07:20:00 1.2 0.2 1.9 0.7 1 0.5 1.9 0.4 0.7 0.4 1.5 0.4 205 1 205 300 -8.5 0.2 -8.1 -8.9 10/31/2005 07:30:00 0.4 0.1 1.1 0.4 0.4 0 0.4 0.4 0.6 0.3 1.5 0.4 201 5 203 300 -8.6 0 -8.5 -8.7 10/31/2005 07:40:00 0.4 0 0.7 0.4 0.4 0 0.4 0.4 0.5 0.2 1.1 0.4 184 5 183 300 -8.5 0.1 -8.3 -8.7 10/31/2005 07:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 181 0 300 300 -8.2 0 -8.1 -8.5 10/31/2005 08:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 181 1 300 300 -8.4 0.2 -8.1 -8.9 10/31/2005 08:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 181 1 300 300 -9 0.1 -8.7 -9.3 10/31/2005 08:20:00 0.4 0.1 0.7 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 185 8 185 300 -9.2 0 -8.9 -9.3 10/31/2005 08:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 201 0 300 300 -8.9 0.1 -8.7 -9.1 10/31/2005 08:40:00 0.5 0.3 1.5 0.4 0.4 0.1 1.1 0.4 0.5 0.3 1.5 0.4 225 24 271 300 -8.6 0 -8.5 -8.7 10/31/2005 08:50:00 1.8 0.4 2.6 1.1 1.6 0.4 2.6 0.7 1.3 0.4 1.9 0.4 272 3 270 300 -8.7 0 -8.5 -8.9 10/31/2005 09:00:00 2.1 0.3 2.6 1.1 1.9 0.4 3 0.7 1.7 0.3 2.3 1.1 309 15 285 300 -8.2 0.4 -7.6 -8.9 10/31/2005 09:10:00 2.1 0.2 2.6 1.5 1.9 0.3 2.3 1.1 2.4 0.5 3.4 1.5 331 5 335 300 -8.3 0.3 -7.6 -8.7 10/31/2005 09:20:00 2.6 0.3 3 1.9 2.4 0.3 3 1.9 2.9 0.2 3.4 2.3 333 3 332 300 -7.8 0.2 -7.4 -8.3 10/31/2005 09:30:00 2.9 0.2 3.4 2.3 2.9 0.2 3.4 2.3 2.5 0.3 3 1.5 346 3 346 300 -7.3 0 -7.2 -7.4 10/31/2005 09:40:00 2.4 0.3 3.4 1.5 2.3 0.4 3.4 1.1 2.1 0.4 3 0.7 329 9 343 300 -6.7 0.3 -6.4 -7.2 10/31/2005 09:50:00 1.4 0.5 2.6 0.4 1.1 0.6 2.3 0.4 0.5 0.3 1.5 0.4 339 9 332 300 -6.4 0 -5.9 -6.6 10/31/2005 10:00:00 1.4 0.2 1.9 0.7 1 0.3 1.9 0.4 0.6 0.3 1.5 0.4 329 6 334 300 -6.1 0.3 -5.5 -6.6 10/31/2005 10:10:00 1.7 0.2 2.3 1.1 1.4 0.2 1.9 0.7 1.3 0.4 2.3 0.4 346 4 345 300 -5.6 0 -5.3 -5.7 10/31/2005 10:20:00 1.9 0.4 2.6 1.1 1.7 0.5 2.6 0.4 1.9 0.4 2.6 1.1 358 11 4 300 -4.9 0.2 -4.4 -5.5 10/31/2005 10:30:00 1.3 0.5 2.3 0.4 0.9 0.6 2.3 0.4 0.9 0.4 1.9 0.4 18 69 11 300 -3.9 0.3 -3.3 -4.4 10/31/2005 10:40:00 0.7 0.4 1.5 0.4 0.5 0.2 1.5 0.4 0.7 0.3 1.5 0.4 113 12 107 300 -2.7 0.3 -2.4 -3.3 10/31/2005 10:50:00 0.8 0.3 1.5 0.4 0.4 0.2 1.5 0.4 0.7 0.3 1.5 0.4 79 18 105 300 -2.4 0.3 -1.9 -2.8 10/31/2005 11:00:00 0.5 0.3 1.5 0.4 0.4 0.1 1.1 0.4 0.7 0.3 1.5 0.4 66 5 63 300 -1.8 0 -1.4 -2.1 10/31/2005 11:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 62 0 300 300 -1.2 0.2 -0.7 -1.7 10/31/2005 11:20:00 0.4 0 0.7 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 78 33 147 300 -0.5 0.3 -0.1 -1 10/31/2005 11:30:00 1.1 0.4 1.9 0.4 0.7 0.4 1.9 0.4 1 0.5 1.9 0.4 139 9 143 300 -0.9 0.5 -0.3 -1.9 10/31/2005 11:40:00 0.9 0.5 2.3 0.4 0.6 0.4 1.9 0.4 1 0.5 2.3 0.4 132 13 131 300 -1.6 0 -1.4 -1.9 10/31/2005 11:50:00 1.1 0.4 1.9 0.4 0.7 0.4 1.9 0.4 1.1 0.4 1.9 0.4 91 20 61 300 -1.1 0.2 -0.7 -1.4 10/31/2005 12:00:00 1.1 0.4 1.9 0.4 0.7 0.4 1.9 0.4 1.1 0.4 2.3 0.4 107 23 60 300 -1.2 0 -1 -1.4 10/31/2005 12:10:00 0.9 0.4 2.3 0.4 0.7 0.4 1.9 0.4 0.9 0.4 2.3 0.4 141 19 146 300 -0.6 0 -0.5 -1.2 10/31/2005 12:20:00 1.1 0.4 2.3 0.4 0.7 0.4 1.9 0.4 1.2 0.4 1.9 0.4 107 26 105 300 -0.6 0 -0.5 -1 10/31/2005 12:30:00 0.8 0.4 1.9 0.4 0.5 0.3 1.5 0.4 0.9 0.3 1.9 0.4 70 12 61 300 -0.8 0.3 -0.3 -1.2 10/31/2005 12:40:00 0.8 0.5 2.3 0.4 0.6 0.4 1.9 0.4 0.9 0.5 1.9 0.4 109 36 118 300 -0.3 0 -0.1 -0.5 10/31/2005 12:50:00 1.5 0.5 2.6 0.4 1.3 0.5 2.6 0.4 1.3 0.5 2.6 0.4 123 26 124 300 0.1 0.1 0.4 -0.3 10/31/2005 13:00:00 1.2 0.6 2.3 0.4 1 0.6 2.6 0.4 1.2 0.5 2.3 0.4 144 22 165 300 0.1 0.2 0.7 -0.3 10/31/2005 13:10:00 1.3 0.4 1.9 0.4 0.9 0.4 1.9 0.4 1.2 0.3 2.3 0.4 152 13 133 300 -0.5 0 -0.1 -0.7 10/31/2005 13:20:00 1.4 0.5 2.3 0.4 1.1 0.5 2.3 0.4 1.4 0.5 2.3 0.4 178 11 156 300 -0.2 0.1 0.2 -0.5 10/31/2005 13:30:00 1.4 0.4 2.3 0.4 1 0.5 1.9 0.4 1.3 0.5 2.3 0.4 179 8 178 300 -0.5 0 -0.5 -0.7 10/31/2005 13:40:00 1.4 0.4 2.3 0.4 1 0.4 1.9 0.4 1.3 0.4 2.3 0.4 165 17 171 300 -0.5 0 -0.1 -0.5 10/31/2005 13:50:00 1 0.5 2.3 0.4 0.7 0.4 1.9 0.4 0.8 0.4 1.9 0.4 153 15 134 300 0.1 0.2 0.7 -0.3 10/31/2005 14:00:00 0.8 0.4 1.9 0.4 0.5 0.3 1.5 0.4 0.8 0.4 1.9 0.4 150 22 181 300 0.3 0.2 0.9 -0.1 10/31/2005 14:10:00 1.3 0.4 2.3 0.4 1.1 0.5 2.3 0.4 1.2 0.4 3 0.4 183 20 171 300 0.4 0.3 0.9 0.2 10/31/2005 14:20:00 1.4 0.4 2.3 0.4 1.1 0.4 2.3 0.4 1.2 0.5 2.3 0.4 189 15 198 300 0 0 0.2 -0.1 10/31/2005 14:30:00 1.6 0.4 2.6 0.7 1.4 0.4 2.6 0.4 1.5 0.4 2.6 0.4 181 12 179 300 -0.3 0 -0.1 -0.5 10/31/2005 14:40:00 1.4 0.5 2.3 0.4 1.2 0.5 2.3 0.4 1.3 0.5 2.3 0.4 181 30 138 300 0.2 0.2 0.7 -0.1 10/31/2005 14:50:00 1.2 0.5 2.3 0.4 0.9 0.5 2.3 0.4 1.1 0.5 2.3 0.4 187 16 189 300 -0.1 0.2 0.2 -0.5 10/31/2005 15:00:00 1.1 0.6 2.6 0.4 1.1 0.6 2.3 0.4 1.2 0.7 2.6 0.4 194 20 187 300 0.2 0.2 0.7 -0.1 10/31/2005 15:10:00 1.1 0.5 2.3 0.4 0.8 0.4 1.9 0.4 1.1 0.5 2.3 0.4 189 19 185 300 -0.2 0 -0.1 -0.5 10/31/2005 15:20:00 0.9 0.4 1.9 0.4 0.7 0.4 1.9 0.4 0.9 0.4 1.9 0.4 182 23 167 300 -0.2 0.1 0.2 -0.5 10/31/2005 15:30:00 0.7 0.4 1.5 0.4 0.5 0.2 1.1 0.4 0.7 0.4 1.5 0.4 169 12 180 300 -0.1 0.1 0.2 -0.5 10/31/2005 15:40:00 0.9 0.4 1.9 0.4 0.7 0.4 1.5 0.4 0.9 0.4 1.9 0.4 209 12 229 300 -0.2 0 -0.1 -0.5 10/31/2005 15:50:00 0.5 0.3 1.1 0.4 0.4 0.1 0.7 0.4 0.6 0.2 1.1 0.4 194 17 181 300 -0.2 0 0.2 -0.5 10/31/2005 16:00:00 0.8 0.4 1.5 0.4 0.6 0.3 1.5 0.4 0.7 0.4 1.5 0.4 186 14 185 300 -0.5 0 -0.3 -0.7 10/31/2005 16:10:00 0.6 0.3 1.5 0.4 0.5 0.2 1.5 0.4 0.7 0.3 1.5 0.4 198 5 194 300 -1.1 0.1 -0.7 -1.4 10/31/2005 16:20:00 1.1 0.6 2.3 0.4 1 0.6 2.3 0.4 0.9 0.5 2.3 0.4 199 9 193 300 -1.4 0 -1.2 -1.7 10/31/2005 16:30:00 1.4 0.4 2.6 0.7 1.5 0.4 2.3 0.7 1.4 0.4 2.3 0.7 198 2 193 300 -2 0.1 -1.4 -2.1 10/31/2005 16:40:00 0.5 0.2 1.1 0.4 0.4 0.1 1.1 0.4 0.6 0.3 1.1 0.4 198 0 199 300 -2.2 0 -2.1 -2.6 10/31/2005 16:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 198 0 300 300 -2.7 0.1 -2.4 -3 10/31/2005 17:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0.1 0.7 0.4 198 0 300 300 -2.9 0 -2.8 -3 10/31/2005 17:10:00 0.4 0.1 0.7 0.4 0.4 0 0.4 0.4 0.5 0.2 0.7 0.4 159 22 146 300 -3 0.1 -2.8 -3.3 10/31/2005 17:20:00 0.7 0.3 1.5 0.4 0.4 0.1 1.1 0.4 0.6 0.2 1.1 0.4 129 14 118 300 -3.5 0.1 -3.3 -3.7 10/31/2005 17:30:00 1.2 0.3 1.9 0.4 0.8 0.4 1.5 0.4 0.9 0.3 1.5 0.4 96 2 94 300 -3.7 0 -3.5 -3.7 10/31/2005 17:40:00 1.9 0.3 2.6 1.1 1.7 0.3 2.3 1.1 1.6 0.3 2.3 1.1 89 5 85 300 -3.8 0 -3.3 -4.2 10/31/2005 17:50:00 2.7 0.2 3 2.3 2.6 0.2 3 2.3 2.3 0.3 3 1.9 80 1 81 300 -4.2 0 -3.5 -4.4 10/31/2005 18:00:00 2.7 0.2 3 1.9 2.5 0.3 3 1.9 2 0.3 2.6 1.5 74 6 85 300 -4.4 0 -4.4 -4.6 10/31/2005 18:10:00 2.9 0.2 3.4 1.9 2.8 0.2 3 1.9 2.3 0.2 3 1.9 69 3 68 300 -4.4 0 -3.9 -4.6 10/31/2005 18:20:00 2.7 0.2 3.4 2.3 2.7 0.3 3.4 1.9 2.1 0.2 2.6 1.9 68 3 72 300 -4.4 0 -4.4 -4.6 10/31/2005 18:30:00 2.9 0.2 3.4 2.3 2.9 0.2 3.4 1.9 2.3 0.2 2.6 1.9 68 3 68 300 -4.8 0 -4.6 -4.8 10/31/2005 18:40:00 3 0.2 3.8 2.3 2.9 0.2 3.4 2.3 2.4 0.2 3 1.9 58 4 55 300 -4.9 0 -4.6 -5 10/31/2005 18:50:00 3.5 0.2 4.2 3 3.5 0.2 4.2 2.6 2.9 0.3 3.8 2.3 50 2 55 300 -5 0 -4.8 -5 10/31/2005 19:00:00 3.2 0.3 4.2 1.9 3.2 0.4 3.8 1.5 2.3 0.5 3.4 0.7 47 6 51 300 -5 0 -5 -5 10/31/2005 19:10:00 3.2 0.3 3.8 2.3 3.1 0.3 3.8 1.9 2.2 0.5 3.4 1.1 47 5 45 300 -5.1 0 -4.8 -5.3 10/31/2005 19:20:00 3.5 0.3 4.2 2.3 3.4 0.3 4.2 1.9 2.5 0.5 3.8 1.1 46 4 53 300 -5.3 0.1 -5 -5.5 10/31/2005 19:30:00 3.1 0.5 4.2 1.9 3 0.5 4.6 1.5 2 0.5 3.4 0.7 43 7 52 300 -5.4 0 -5.3 -5.7 10/31/2005 19:40:00 3 0.4 3.8 1.9 2.9 0.4 3.8 1.5 1.8 0.4 3 0.7 42 6 28 300 -5.3 0 -4.8 -5.5 10/31/2005 19:50:00 3 0.3 3.8 2.3 2.8 0.4 3.8 1.5 1.8 0.4 3 1.1 37 8 47 300 -5.3 0 -5 -5.5 10/31/2005 20:00:00 2.6 0.2 3.4 1.9 2.4 0.3 3 1.5 1.6 0.4 2.6 0.7 28 8 35 300 -5.2 0 -5 -5.3 10/31/2005 20:10:00 2.4 0.2 3 1.9 2.1 0.3 2.6 1.5 1.8 0.4 2.6 0.7 24 7 21 300 -5.3 0 -5 -5.5 10/31/2005 20:20:00 2.5 0.3 3 1.9 2.2 0.3 3 1.5 2.1 0.4 3 1.1 27 8 38 300 -5.4 0.1 -4.8 -5.7 10/31/2005 20:30:00 2.4 0.3 3 1.9 2.2 0.3 3 1.5 2.3 0.4 3 1.5 15 9 37 300 -5.9 0 -5.7 -6.1 10/31/2005 20:40:00 2.5 0.2 3 1.9 2.3 0.3 3 1.5 2.2 0.3 3 1.1 18 10 359 300 -6 0 -5.9 -6.1 10/31/2005 20:50:00 2.2 0.3 2.6 1.5 1.9 0.3 2.6 1.5 2.3 0.2 3 1.9 10 13 22 300 -6 0 -5.7 -6.4 10/31/2005 21:00:00 2 0.3 2.6 1.5 1.8 0.3 2.6 1.1 2.6 0.3 3.4 1.9 339 8 344 300 -6.3 0 -6.1 -6.6 10/31/2005 21:10:00 2.2 0.2 2.6 1.5 2 0.3 2.6 1.5 2.7 0.2 3 2.3 337 4 339 300 -6.4 0.1 -5.7 -6.6 10/31/2005 21:20:00 1.7 0.4 2.6 0.7 1.4 0.4 2.6 0.4 2.1 0.3 2.6 1.5 343 1 341 300 -6.6 0.2 -6.1 -7 10/31/2005 21:30:00 1.4 0.2 1.9 0.7 1.1 0.2 1.5 0.4 1.6 0.2 1.9 1.1 344 4 342 300 -7.2 0.2 -6.6 -7.4 10/31/2005 21:40:00 1.5 0.2 1.9 0.7 1.1 0.2 1.5 0.4 1.9 0.4 2.6 1.1 354 4 352 300 -7.3 0 -7.2 -7.4 10/31/2005 21:50:00 1.4 0.3 2.3 0.7 1 0.4 1.9 0.4 1.5 0.3 2.3 0.7 24 20 21 300 -7.3 0.1 -7 -7.6 10/31/2005 22:00:00 0.8 0.3 1.1 0.4 0.5 0.2 1.1 0.4 0.8 0.3 1.5 0.4 55 0 55 300 -7.9 0.1 -7.6 -8.1 10/31/2005 22:10:00 0.6 0.4 1.5 0.4 0.5 0.2 1.1 0.4 0.9 0.4 1.5 0.4 52 6 45 300 -8.3 0.1 -7.9 -8.5 10/31/2005 22:20:00 0.6 0.2 1.1 0.4 0.4 0.1 0.7 0.4 0.5 0.2 1.1 0.4 37 0 36 300 -8.8 0 -8.5 -8.9 10/31/2005 22:30:00 0.7 0.4 1.9 0.4 0.5 0.3 1.5 0.4 0.5 0.3 1.5 0.4 17 22 347 300 -8.9 0.1 -8.5 -8.9 10/31/2005 22:40:00 1.3 0.8 2.6 0.4 1.1 0.8 2.6 0.4 1.4 0.7 2.6 0.4 14 26 42 300 -8.6 0 -8.5 -8.9 10/31/2005 22:50:00 2.5 0.7 3.8 1.5 2.3 0.8 3.8 0.7 2.2 0.5 3.4 1.1 34 5 28 300 -8.9 0.3 -7.9 -9.1 10/31/2005 23:00:00 2.6 0.5 3.4 1.5 2.4 0.6 3.4 1.1 2 0.5 3 1.1 44 10 43 300 -8.2 0.4 -7.6 -8.9 10/31/2005 23:10:00 1.8 0.8 3.4 0.4 1.5 0.9 3.4 0.4 1.3 0.7 3.4 0.4 61 82 41 300 -9.3 0.2 -8.7 -9.7 10/31/2005 23:20:00 2.2 0.8 3.8 0.4 2 0.9 3.8 0.4 1.8 0.7 3.4 0.4 35 22 48 300 -8.9 0.3 -8.5 -9.3 10/31/2005 23:30:00 1.7 0.4 2.3 0.7 1.4 0.4 2.3 0.4 1.4 0.4 2.6 0.4 46 15 9 300 -9.6 0.1 -9.3 -9.7 10/31/2005 23:40:00 1.4 0.4 2.3 0.4 1 0.5 1.9 0.4 1.3 0.3 1.9 0.7 40 12 49 300 -9.7 0 -9.3 -9.7 10/31/2005 23:50:00 1.6 0.3 2.3 1.1 1.4 0.3 2.3 0.7 1.3 0.2 1.9 0.7 50 8 60 300 -9.6 0.1 -9.1 -9.7 11/01/2005 00:00:00 1.8 0.3 2.3 1.1 1.5 0.3 2.3 0.7 1.3 0.3 1.9 0.7 53 9 37 300 -9.8 0 -9.5 -10 11/01/2005 00:10:00 1.3 0.3 1.9 0.7 0.9 0.5 1.9 0.4 0.8 0.5 1.9 0.4 50 10 63 300 -9.9 0.1 -9.7 -10.2 11/01/2005 00:20:00 1.4 0.3 1.9 0.7 0.9 0.4 1.9 0.4 0.8 0.4 1.5 0.4 35 8 44 300 -10.4 0 -10.2 -10.6 11/01/2005 00:30:00 2.1 0.3 2.6 1.1 1.9 0.4 2.6 0.7 1.3 0.3 2.3 0.7 44 4 45 300 -10.5 0 -10.4 -10.6 11/01/2005 00:40:00 2.8 0.4 3.8 2.3 2.7 0.4 3.4 1.9 1.8 0.5 2.6 1.1 49 6 53 300 -10.3 0.1 -10.2 -10.6 11/01/2005 00:50:00 3.4 0.3 3.8 2.6 3.3 0.3 3.8 2.6 2.5 0.4 3.4 1.9 55 4 54 300 -10.5 0 -10.2 -10.6 11/01/2005 01:00:00 3.4 0.2 3.8 3 3.3 0.2 3.8 3 2.6 0.3 3.4 1.5 61 4 61 300 -10 0.4 -9.3 -10.6 11/01/2005 01:10:00 3.5 0.2 3.8 3 3.5 0.2 3.8 3 2.7 0.2 3.4 1.9 54 4 63 300 -9 0 -8.9 -9.3 11/01/2005 01:20:00 3.6 0.3 4.2 2.6 3.5 0.3 4.6 2.6 2.6 0.4 3.4 1.1 46 5 51 300 -9.3 0.3 -8.5 -9.7 11/01/2005 01:30:00 3.4 0.3 4.2 2.6 3.4 0.4 4.2 2.3 2.3 0.4 3.4 1.1 42 5 45 300 -8.2 0.1 -7.9 -8.5 11/01/2005 01:40:00 3.4 0.3 4.2 2.6 3.2 0.4 4.2 2.3 2.2 0.4 3.4 1.1 37 6 41 300 -8.4 0.1 -8.1 -8.7 11/01/2005 01:50:00 3.5 0.3 4.2 3 3.2 0.3 3.8 2.3 2 0.4 3 1.1 32 6 29 300 -8.1 0 -7.9 -8.3 11/01/2005 02:00:00 3.5 0.3 4.2 3 3.4 0.3 4.2 2.6 2.1 0.4 3 1.1 35 5 36 300 -8.1 0 -7.9 -8.1 11/01/2005 02:10:00 3.5 0.3 4.2 2.6 3.2 0.4 3.8 1.9 2.2 0.4 3.4 1.1 28 6 22 300 -8.1 0 -7.9 -8.1 11/01/2005 02:20:00 3.3 0.2 3.8 2.6 3.1 0.3 3.8 1.9 1.9 0.3 3 1.1 32 6 24 300 -8.2 0 -8.1 -8.3 11/01/2005 02:30:00 2.8 0.5 3.8 1.9 2.6 0.6 3.8 1.5 2.1 0.4 3 1.1 32 9 27 300 -8.2 0.1 -7.9 -8.5 11/01/2005 02:40:00 2.6 0.3 3.4 1.9 2.4 0.3 3 1.5 1.7 0.3 3 0.7 37 6 27 300 -8 0.3 -7.6 -8.7 11/01/2005 02:50:00 2.6 0.2 3 2.3 2.6 0.3 3 1.9 2.2 0.2 3 1.5 47 6 43 300 -9.3 0.4 -8.7 -9.7 11/01/2005 03:00:00 2.9 0.4 3.4 1.9 2.8 0.5 3.8 1.9 2.4 0.4 3 1.9 50 3 47 300 -9.6 0.2 -9.3 -10 11/01/2005 03:10:00 3.9 0.4 4.6 3 3.9 0.4 4.6 3 3.1 0.3 4.2 2.3 51 3 48 300 -10.1 0 -9.7 -10.2 11/01/2005 03:20:00 3.9 0.3 4.6 2.6 3.9 0.4 4.6 2.3 2.7 0.5 3.8 1.5 45 4 51 300 -9.7 0.2 -9.3 -10.2 11/01/2005 03:30:00 3.5 0.3 4.2 2.6 3.5 0.3 4.6 2.6 2.3 0.4 3.4 1.1 46 5 45 300 -9.2 0.1 -8.9 -9.5 11/01/2005 03:40:00 3.7 0.3 4.6 2.6 3.6 0.4 4.6 2.3 2.1 0.4 3 1.1 34 5 39 300 -8.7 0 -8.5 -8.9 11/01/2005 03:50:00 3.5 0.3 4.2 2.6 3.4 0.3 4.2 2.3 2.1 0.4 3.4 1.5 38 6 32 300 -8.3 0.1 -8.1 -8.7 11/01/2005 04:00:00 3 0.2 3.4 2.3 3 0.3 3.4 1.9 1.9 0.3 2.6 1.1 44 4 42 300 -8.5 0.2 -8.1 -8.7 11/01/2005 04:10:00 3.2 0.3 4.2 2.3 3.1 0.3 3.8 1.9 2 0.4 3 1.5 40 4 42 300 -9.2 0.2 -8.7 -9.3 11/01/2005 04:20:00 3.6 0.3 4.2 2.6 3.5 0.4 4.6 2.3 2.3 0.4 3.4 1.1 38 4 34 300 -8.8 0.2 -8.3 -9.3 11/01/2005 04:30:00 3.5 0.3 4.2 3 3.5 0.3 4.2 2.6 2.5 0.4 3.4 1.5 46 6 43 300 -8 0.1 -7.6 -8.3 11/01/2005 04:40:00 2.8 0.3 3.4 1.9 2.7 0.3 3.4 1.9 2.2 0.3 3 1.5 61 5 54 300 -7.9 0.2 -7.6 -8.1 11/01/2005 04:50:00 1.8 0.9 3 0.4 1.6 1 3 0.4 1 0.7 2.3 0.4 63 6 63 300 -8.1 0.3 -7.6 -8.5 11/01/2005 05:00:00 0.4 0.2 1.1 0.4 0.4 0.1 1.1 0.4 0.4 0 0.4 0.4 56 0 57 300 -9 0.3 -8.1 -9.5 11/01/2005 05:10:00 0.9 0.4 1.5 0.4 0.6 0.3 1.5 0.4 0.4 0 0.4 0.4 43 5 43 300 -9.5 0.1 -9.3 -9.7 11/01/2005 05:20:00 1 0.4 1.9 0.4 0.6 0.3 1.5 0.4 0.4 0 0.4 0.4 39 3 34 300 -9.6 0 -9.3 -9.7 11/01/2005 05:30:00 1.1 0.4 1.9 0.4 0.8 0.4 1.9 0.4 0.4 0 0.7 0.4 42 0 42 300 -9.5 0 -9.3 -9.7 11/01/2005 05:40:00 0.7 0.4 1.5 0.4 0.5 0.3 1.1 0.4 0.7 0.3 1.5 0.4 107 53 160 300 -9.8 0 -9.5 -10 11/01/2005 05:50:00 0.7 0.4 1.9 0.4 0.6 0.4 1.5 0.4 0.7 0.4 1.5 0.4 133 56 219 300 -10.1 0.2 -9.5 -10.4 11/01/2005 06:00:00 2.1 0.6 3 1.1 1.8 0.7 3 0.7 1.2 0.8 2.6 0.4 239 9 244 300 -10 0.1 -9.7 -10.2 11/01/2005 06:10:00 2.2 0.3 3 1.5 2 0.3 3 1.1 2 0.4 3 1.1 246 5 248 300 -10 0 -9.7 -10.2 11/01/2005 06:20:00 2 0.3 2.6 1.5 1.7 0.4 2.6 0.7 1.3 0.4 2.3 0.7 234 9 226 300 -10.1 0 -9.7 -10.4 11/01/2005 06:30:00 2.4 0.4 3.4 1.9 2.2 0.4 3 1.5 1.6 0.5 2.6 0.7 238 10 246 300 -10.3 0 -10 -10.6 11/01/2005 06:40:00 2.2 0.4 3.4 1.5 2 0.4 3 1.1 1.5 0.4 2.6 1.1 253 6 245 300 -10.4 0.2 -10 -10.6 11/01/2005 06:50:00 1.3 0.5 2.6 0.4 0.9 0.5 2.3 0.4 0.9 0.5 1.9 0.4 251 4 242 300 -10.6 0 -10.2 -10.6 11/01/2005 07:00:00 1.1 0.2 1.5 0.4 0.8 0.3 1.5 0.4 1 0.4 1.5 0.4 216 19 249 300 -10.4 0 -10.4 -10.6 11/01/2005 07:10:00 1.3 0.5 2.6 0.4 1.1 0.5 2.3 0.4 1.1 0.4 1.9 0.4 214 12 226 300 -10.6 0.2 -10.2 -11 11/01/2005 07:20:00 0.5 0.2 1.1 0.4 0.4 0 0.7 0.4 0.5 0.3 1.5 0.4 256 47 224 300 -10.1 0 -10 -10.2 11/01/2005 07:30:00 0.5 0.2 1.5 0.4 0.4 0.1 1.1 0.4 0.4 0.1 1.1 0.4 297 33 246 300 -10.1 0 -10 -10.2 11/01/2005 07:40:00 0.4 0.1 0.7 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 246 0 246 300 -9.8 0 -9.7 -10.2 11/01/2005 07:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.5 0.2 1.1 0.4 246 0 300 300 -10 0 -9.7 -10.2 11/01/2005 08:00:00 0.4 0.1 1.1 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 208 8 207 300 -9.5 0 -9.3 -9.7 11/01/2005 08:10:00 0.8 0.3 1.5 0.4 0.5 0.2 1.1 0.4 0.4 0 0.4 0.4 220 6 221 300 -9.3 0 -9.3 -9.5 11/01/2005 08:20:00 1.3 0.3 1.9 0.4 0.9 0.3 1.5 0.4 0.6 0.3 1.1 0.4 235 11 249 300 -9.1 0.1 -8.9 -9.3 11/01/2005 08:30:00 1.1 0.4 1.9 0.4 0.8 0.4 1.9 0.4 0.5 0.2 1.1 0.4 265 12 248 300 -8.9 0 -8.7 -8.9 11/01/2005 08:40:00 0.9 0.5 1.9 0.4 0.7 0.4 1.9 0.4 0.6 0.3 1.5 0.4 242 28 256 300 -8.6 0.1 -8.3 -8.9 11/01/2005 08:50:00 0.4 0.1 0.7 0.4 0.4 0 0.4 0.4 0.4 0.1 0.7 0.4 211 0 211 300 -8.2 0 -8.1 -8.5 11/01/2005 09:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 221 3 300 300 -8.3 0 -8.1 -8.5 11/01/2005 09:10:00 1 0.5 2.3 0.4 0.8 0.5 2.3 0.4 0.8 0.4 1.9 0.4 168 30 156 300 -7.9 0.2 -7.6 -8.1 11/01/2005 09:20:00 0.4 0.1 0.7 0.4 0.4 0 0.7 0.4 0.4 0.2 1.1 0.4 116 6 131 300 -7.6 0 -7.6 -7.6 11/01/2005 09:30:00 0.5 0.2 1.1 0.4 0.4 0.1 0.7 0.4 0.7 0.3 1.5 0.4 83 15 104 300 -7.5 0 -7.4 -7.6 11/01/2005 09:40:00 0.4 0 0.7 0.4 0.4 0 0.4 0.4 0.6 0.3 1.1 0.4 62 12 43 300 -7.5 0 -7.2 -7.6 11/01/2005 09:50:00 0.4 0.1 0.7 0.4 0.4 0 0.4 0.4 0.4 0.1 1.1 0.4 61 21 79 300 -7.2 0 -7 -7.4 11/01/2005 10:00:00 0.4 0.2 1.1 0.4 0.4 0.1 0.7 0.4 0.5 0.3 1.9 0.4 95 22 59 300 -7.1 0 -7 -7.2 11/01/2005 10:10:00 0.4 0.2 1.5 0.4 0.4 0.1 1.1 0.4 0.6 0.3 1.1 0.4 78 16 88 300 -7.1 0 -7 -7.2 11/01/2005 10:20:00 0.7 0.3 1.5 0.4 0.5 0.2 1.1 0.4 0.8 0.3 1.5 0.4 101 19 123 300 -7.2 0 -7 -7.2 11/01/2005 10:30:00 0.5 0.2 1.1 0.4 0.4 0.1 1.1 0.4 0.6 0.3 1.5 0.4 57 16 73 300 -7.2 0.1 -7 -7.4 11/01/2005 10:40:00 0.8 0.4 1.9 0.4 0.6 0.3 1.5 0.4 0.7 0.4 1.5 0.4 47 13 72 300 -7.4 0.1 -7.2 -7.6 11/01/2005 10:50:00 0.5 0.3 1.5 0.4 0.4 0.1 1.1 0.4 0.5 0.3 1.5 0.4 48 17 15 300 -7.6 0 -7.4 -7.6 11/01/2005 11:00:00 0.4 0.1 0.7 0.4 0.4 0 0.7 0.4 0.4 0.1 1.1 0.4 69 11 61 300 -7.5 0 -7.2 -7.6 11/01/2005 11:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0.1 1.1 0.4 59 0 300 300 -7.2 0.1 -7 -7.4 11/01/2005 11:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 59 0 300 300 -7 0 -6.8 -7.2 11/01/2005 11:30:00 0.4 0 0.7 0.4 0.4 0 0.4 0.4 0.4 0.1 0.7 0.4 111 56 170 300 -6.8 0 -6.6 -7 11/01/2005 11:40:00 0.4 0.1 0.7 0.4 0.4 0 0.7 0.4 0.4 0.2 1.1 0.4 189 33 181 300 -6.4 0 -6.1 -6.6 11/01/2005 11:50:00 0.5 0.2 1.1 0.4 0.4 0.1 0.7 0.4 0.6 0.3 1.5 0.4 213 32 194 300 -6.7 0 -6.6 -7 11/01/2005 12:00:00 1 0.5 1.9 0.4 0.8 0.4 1.9 0.4 1 0.5 1.9 0.4 236 13 225 300 -6.7 0 -6.6 -6.8 11/01/2005 12:10:00 1.6 0.5 2.6 0.4 1.4 0.5 2.3 0.4 1.7 0.5 2.6 0.4 227 13 220 300 -6.5 0 -6.4 -6.8 11/01/2005 12:20:00 1.4 0.6 2.6 0.4 1.2 0.6 2.6 0.4 1.5 0.6 3 0.4 233 19 251 300 -6.3 0 -6.1 -6.6 11/01/2005 12:30:00 1.6 0.4 2.3 0.4 1.3 0.5 2.3 0.4 1.7 0.4 2.6 0.7 255 11 242 300 -6.2 0 -6.1 -6.4 11/01/2005 12:40:00 1.7 0.3 2.6 1.1 1.6 0.4 2.3 0.7 1.8 0.3 2.6 1.1 252 19 278 300 -6.1 0 -5.9 -6.4 11/01/2005 12:50:00 1.8 0.4 2.6 0.4 1.7 0.5 3 0.4 2 0.5 3 0.7 237 22 261 300 -5.9 0 -5.7 -6.1 11/01/2005 13:00:00 1.9 0.7 3.4 0.4 1.9 0.8 3.4 0.4 2.1 0.7 3.4 0.4 225 19 222 300 -5.9 0 -5.7 -5.9 11/01/2005 13:10:00 1.4 0.6 2.6 0.4 1.3 0.7 2.6 0.4 1.4 0.7 2.6 0.4 219 21 207 300 -5.7 0 -5.5 -5.9 11/01/2005 13:20:00 1.1 0.5 2.3 0.4 0.8 0.5 2.3 0.4 0.9 0.5 1.9 0.4 234 23 224 300 -5.5 0 -5.3 -5.7 11/01/2005 13:30:00 1.3 0.5 2.3 0.4 1.2 0.5 2.3 0.4 1.4 0.5 2.3 0.4 223 13 222 300 -5.3 0 -5 -5.5 11/01/2005 13:40:00 1.2 0.6 2.6 0.4 1 0.6 2.3 0.4 1.3 0.6 3 0.4 227 11 229 300 -5.2 0 -5 -5.3 11/01/2005 13:50:00 1.4 0.4 2.6 0.4 1.2 0.5 2.6 0.4 1.3 0.4 2.3 0.4 227 15 224 300 -5.1 0 -5 -5.3 11/01/2005 14:00:00 0.9 0.5 2.3 0.4 0.8 0.5 1.9 0.4 0.9 0.6 2.3 0.4 215 17 195 300 -5.1 0 -5 -5.3 11/01/2005 14:10:00 0.7 0.4 1.9 0.4 0.6 0.4 1.9 0.4 0.8 0.4 1.9 0.4 209 16 236 300 -4.9 0 -4.6 -5 11/01/2005 14:20:00 1.6 0.4 2.6 0.7 1.4 0.4 2.6 0.4 1.5 0.4 2.3 0.4 226 13 210 300 -5 0 -4.8 -5 11/01/2005 14:30:00 1.4 0.3 2.3 0.7 1.2 0.3 2.3 0.4 1.4 0.4 2.3 0.4 239 20 263 300 -5.1 0 -5 -5.3 11/01/2005 14:40:00 1.3 0.4 2.6 0.4 1.3 0.5 2.3 0.4 1.4 0.4 2.3 0.4 221 16 222 300 -5.2 0 -5 -5.3 11/01/2005 14:50:00 1.1 0.4 1.9 0.4 0.9 0.4 1.9 0.4 1.1 0.4 1.9 0.4 212 15 189 300 -5.2 0 -4.6 -5.3 11/01/2005 15:00:00 0.9 0.4 1.9 0.4 0.6 0.3 1.5 0.4 0.8 0.4 1.9 0.4 237 19 239 300 -5.3 0 -5 -5.5 11/01/2005 15:10:00 0.9 0.4 1.9 0.4 0.6 0.3 1.5 0.4 0.8 0.5 1.9 0.4 232 15 239 300 -5.3 0 -5 -5.3 11/01/2005 15:20:00 1.1 0.4 1.9 0.4 0.8 0.4 1.9 0.4 0.9 0.4 1.9 0.4 187 17 171 300 -5.2 0 -5 -5.3 11/01/2005 15:30:00 0.8 0.4 2.3 0.4 0.6 0.4 1.9 0.4 0.7 0.3 1.5 0.4 193 20 196 300 -5.2 0 -5 -5.3 11/01/2005 15:40:00 0.9 0.5 2.3 0.4 0.6 0.4 2.3 0.4 0.7 0.5 1.9 0.4 223 16 178 300 -5.1 0 -4.6 -5.3 11/01/2005 15:50:00 1.1 0.4 2.3 0.4 0.8 0.5 2.3 0.4 1 0.5 2.3 0.4 226 18 220 300 -5.2 0 -5 -5.3 11/01/2005 16:00:00 1.5 0.4 2.3 0.4 1.3 0.5 2.3 0.4 1.4 0.5 2.6 0.4 223 15 227 300 -5.3 0 -5 -5.5 11/01/2005 16:10:00 0.9 0.3 1.9 0.4 0.7 0.3 1.5 0.4 0.9 0.3 1.5 0.4 215 12 192 300 -5.4 0 -5.3 -5.5 11/01/2005 16:20:00 0.4 0.2 1.5 0.4 0.4 0.1 1.1 0.4 0.4 0.2 1.1 0.4 225 3 223 300 -5.5 0 -5.5 -5.7 11/01/2005 16:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 227 0 300 300 -5.8 0 -5.7 -5.9 11/01/2005 16:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 227 0 300 300 -5.9 0 -5.7 -5.9 11/01/2005 16:50:00 0.6 0.2 1.1 0.4 0.4 0 0.4 0.4 0.7 0.3 1.1 0.4 102 79 26 300 -6 0 -5.9 -6.1 11/01/2005 17:00:00 1 0.2 1.5 0.4 0.6 0.2 1.1 0.4 1.1 0.2 1.5 0.7 55 1 56 300 -6 0 -5.9 -6.1 11/01/2005 17:10:00 0.8 0.2 1.1 0.4 0.5 0.2 1.1 0.4 0.8 0.2 1.1 0.4 55 3 54 300 -6.2 0 -6.1 -6.4 11/01/2005 17:20:00 1 0.3 1.5 0.4 0.8 0.3 1.5 0.4 1.2 0.2 1.5 0.7 59 8 69 300 -6.4 0 -6.1 -6.6 11/01/2005 17:30:00 1.1 0.2 1.5 0.7 0.8 0.3 1.5 0.4 1.1 0.2 1.5 0.7 60 5 55 300 -6.4 0 -6.1 -6.6 11/01/2005 17:40:00 1.2 0.2 1.9 0.7 0.9 0.2 1.5 0.4 1 0.2 1.5 0.7 54 2 56 300 -6.5 0 -6.1 -6.8 11/01/2005 17:50:00 1.5 0.2 1.9 1.1 1.3 0.2 1.5 0.7 1.2 0.2 1.5 0.7 53 3 47 300 -6.7 0 -6.6 -6.8 11/01/2005 18:00:00 1.3 0.2 1.9 0.7 1.1 0.3 1.5 0.4 0.8 0.3 1.5 0.4 53 3 51 300 -6.7 0 -6.6 -6.8 11/01/2005 18:10:00 0.9 0.3 1.5 0.4 0.5 0.2 1.1 0.4 0.7 0.2 1.1 0.4 68 8 53 300 -6.7 0 -6.6 -7 11/01/2005 18:20:00 0.4 0 0.7 0.4 0.4 0 0.4 0.4 0.7 0.2 1.1 0.4 64 1 64 300 -7.1 0 -6.8 -7.2 11/01/2005 18:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0.2 0.7 0.4 64 0 300 300 -7.3 0 -7.2 -7.4 11/01/2005 18:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 64 0 300 300 -7.6 0 -7.2 -7.9 11/01/2005 18:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 64 0 300 300 -8 0.1 -7.6 -8.1 11/01/2005 19:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 64 0 300 300 -8.2 0 -8.1 -8.3 11/01/2005 19:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 64 0 300 300 -8.3 0 -8.1 -8.5 11/01/2005 19:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 64 0 300 300 -8.4 0.1 -8.1 -8.7 11/01/2005 19:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 64 0 300 300 -8.7 0 -8.7 -8.9 11/01/2005 19:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 64 0 300 300 -8.9 0 -8.7 -9.1 11/01/2005 19:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 64 0 300 300 -9.1 0 -8.9 -9.1 11/01/2005 20:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 64 0 300 300 -9 0 -8.9 -9.1 11/01/2005 20:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 64 0 300 300 -9.1 0 -8.9 -9.3 11/01/2005 20:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 64 0 300 300 -9.3 0 -9.1 -9.3 11/01/2005 20:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 64 0 300 300 -9.3 0 -9.1 -9.5 11/01/2005 20:40:00 0.4 0.1 1.1 0.4 0.4 0 0.4 0.4 0.4 0.1 0.7 0.4 64 0 64 300 -9.4 0.1 -9.3 -9.7 11/01/2005 20:50:00 0.8 0.2 1.1 0.4 0.4 0.1 0.7 0.4 0.6 0.2 1.1 0.4 62 4 64 300 -9.3 0 -9.3 -9.5 11/01/2005 21:00:00 0.8 0.2 1.1 0.4 0.4 0.2 0.7 0.4 0.5 0.2 1.1 0.4 50 5 48 300 -9.7 0.1 -9.3 -9.7 11/01/2005 21:10:00 0.6 0.2 1.1 0.4 0.4 0 0.7 0.4 0.4 0.1 1.1 0.4 36 3 34 300 -9.5 0 -9.3 -9.7 11/01/2005 21:20:00 0.8 0.2 1.1 0.4 0.4 0.2 1.1 0.4 0.5 0.2 1.1 0.4 42 0 42 300 -9.6 0.1 -9.5 -9.7 11/01/2005 21:30:00 1.4 0.2 1.9 1.1 1.2 0.2 1.5 0.7 0.9 0.2 1.5 0.4 40 2 42 300 -9.7 0.1 -9.5 -9.7 11/01/2005 21:40:00 1.4 0.2 1.9 1.1 1.2 0.1 1.5 0.7 0.9 0.2 1.5 0.4 45 1 44 300 -9.5 0 -9.3 -9.7 11/01/2005 21:50:00 1.3 0.2 1.5 1.1 1 0.2 1.5 0.7 1.2 0.2 1.5 0.7 48 2 45 300 -9.2 0.1 -8.9 -9.5 11/01/2005 22:00:00 0.7 0.2 1.1 0.4 0.4 0.2 1.1 0.4 1 0.3 1.5 0.4 47 0 47 300 -8.9 0.1 -8.7 -9.1 11/01/2005 22:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0.2 1.1 0.4 47 0 300 300 -8.8 0 -8.7 -9.1 11/01/2005 22:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.5 0.2 1.1 0.4 47 0 300 300 -9.8 0.3 -9.1 -10.2 11/01/2005 22:30:00 0.6 0.2 1.1 0.4 0.4 0.1 0.7 0.4 0.9 0.2 1.5 0.4 45 1 47 300 -9.9 0.1 -9.5 -10.2 11/01/2005 22:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.7 0.2 1.1 0.4 44 0 300 300 -9.9 0 -9.5 -10.2 11/01/2005 22:50:00 0.4 0.2 1.1 0.4 0.4 0.1 0.7 0.4 0.9 0.3 1.5 0.4 44 0 44 300 -9.8 0 -9.7 -10.2 11/01/2005 23:00:00 0.6 0.3 1.1 0.4 0.4 0.1 0.7 0.4 0.9 0.2 1.1 0.4 57 8 63 300 -10 0 -9.7 -10.2 11/01/2005 23:10:00 1 0.2 1.5 0.4 0.7 0.3 1.1 0.4 1.1 0.2 1.5 0.7 59 3 64 300 -10 0 -9.7 -10.2 11/01/2005 23:20:00 1.2 0.3 1.9 0.7 0.8 0.3 1.5 0.4 1.1 0.2 1.9 0.4 63 4 57 300 -9.8 0 -9.7 -10 11/01/2005 23:30:00 1.1 0.2 1.5 0.7 0.7 0.3 1.5 0.4 1 0.2 1.5 0.4 64 5 72 300 -9.6 0 -9.5 -9.7 11/01/2005 23:40:00 1.2 0.2 1.9 0.7 0.8 0.2 1.5 0.4 1 0.3 1.5 0.4 68 4 65 300 -9.5 0 -9.3 -9.7 11/01/2005 23:50:00 1.3 0.2 1.9 0.7 1 0.2 1.5 0.4 1.1 0.3 1.9 0.4 64 6 62 300 -9.1 0.3 -8.5 -9.5 11/02/2005 00:00:00 1.1 0.3 1.9 0.7 0.9 0.3 1.5 0.4 0.9 0.3 1.5 0.4 56 6 61 300 -8.7 0 -8.5 -8.7 11/02/2005 00:10:00 0.7 0.3 1.1 0.4 0.4 0.2 1.1 0.4 0.5 0.2 1.1 0.4 58 6 57 300 -8.7 0 -8.7 -8.9 11/02/2005 00:20:00 0.6 0.3 1.1 0.4 0.4 0.1 0.7 0.4 0.4 0.2 1.1 0.4 69 3 65 300 -8.4 0 -8.1 -8.7 11/02/2005 00:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0.1 1.1 0.4 65 0 300 300 -8.2 0 -8.1 -8.3 11/02/2005 00:40:00 0.6 0.2 1.1 0.4 0.4 0.1 0.7 0.4 0.5 0.3 1.5 0.4 52 10 50 300 -8.4 0 -8.1 -8.5 11/02/2005 00:50:00 1.1 0.2 1.5 0.7 0.8 0.2 1.1 0.4 1 0.3 1.5 0.4 49 5 49 300 -8.3 0 -8.3 -8.5 11/02/2005 01:00:00 0.8 0.2 1.1 0.4 0.5 0.2 1.1 0.4 0.6 0.3 1.1 0.4 46 8 43 300 -8.4 0 -8.3 -8.5 11/02/2005 01:10:00 0.5 0.2 1.5 0.4 0.4 0.1 1.1 0.4 0.4 0.1 0.7 0.4 36 8 53 300 -8.5 0 -8.5 -8.7 11/02/2005 01:20:00 0.4 0 0.7 0.4 0.4 0 0.4 0.4 0.4 0 0.7 0.4 38 5 39 300 -8.6 0 -8.5 -8.7 11/02/2005 01:30:00 0.5 0.2 1.1 0.4 0.4 0.1 0.7 0.4 0.4 0.2 1.1 0.4 46 9 43 300 -8.7 0 -8.7 -8.9 11/02/2005 01:40:00 0.4 0.1 1.1 0.4 0.4 0 0.7 0.4 0.4 0.1 0.7 0.4 53 6 43 300 -8.8 0 -8.7 -8.9 11/02/2005 01:50:00 0.4 0.1 0.7 0.4 0.4 0 0.4 0.4 0.4 0.1 0.7 0.4 48 6 52 300 -8.9 0 -8.9 -8.9 11/02/2005 02:00:00 0.5 0.2 1.1 0.4 0.4 0.1 0.7 0.4 0.5 0.2 1.1 0.4 44 6 43 300 -8.8 0 -8.7 -8.9 11/02/2005 02:10:00 0.9 0.2 1.5 0.4 0.6 0.2 1.1 0.4 0.8 0.3 1.5 0.4 45 9 39 300 -8.8 0 -8.7 -8.9 11/02/2005 02:20:00 0.9 0.2 1.5 0.4 0.5 0.2 1.1 0.4 0.7 0.3 1.1 0.4 56 10 52 300 -8.7 0 -8.7 -8.9 11/02/2005 02:30:00 0.8 0.2 1.1 0.4 0.5 0.2 1.1 0.4 0.6 0.2 1.1 0.4 44 9 48 300 -8.7 0 -8.7 -8.7 11/02/2005 02:40:00 0.8 0.2 1.5 0.4 0.5 0.2 1.1 0.4 0.5 0.2 1.1 0.4 45 6 57 300 -8.7 0 -8.5 -8.7 11/02/2005 02:50:00 0.4 0.2 1.1 0.4 0.4 0 0.7 0.4 0.4 0.1 1.1 0.4 68 16 52 300 -8.7 0 -8.7 -8.7 11/02/2005 03:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 84 0 300 300 -8.8 0 -8.7 -8.9 11/02/2005 03:10:00 0.4 0.1 0.7 0.4 0.4 0 0.4 0.4 0.4 0 0.7 0.4 80 23 87 300 -9 0 -8.9 -9.1 11/02/2005 03:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 112 12 300 300 -9.1 0 -8.9 -9.3 11/02/2005 03:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.7 0.4 95 21 300 300 -9.3 0 -9.3 -9.3 11/02/2005 03:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.7 0.4 53 6 300 300 -9.4 0 -9.3 -9.5 11/02/2005 03:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 79 20 300 300 -9.4 0 -9.3 -9.5 11/02/2005 04:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 84 1 300 300 -9.3 0 -9.3 -9.3 11/02/2005 04:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 84 0 300 300 -9.3 0 -9.3 -9.3 11/02/2005 04:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.7 0.4 63 10 300 300 -9.3 0 -9.3 -9.3 11/02/2005 04:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.5 0.2 1.1 0.4 58 7 300 300 -9.2 0 -8.9 -9.3 11/02/2005 04:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.7 0.4 38 6 300 300 -9 0 -8.9 -9.1 11/02/2005 04:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 52 22 300 300 -9 0 -8.9 -9.1 11/02/2005 05:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 97 7 300 300 -9 0 -8.9 -9.1 11/02/2005 05:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 64 9 300 300 -9 0 -8.9 -9.1 11/02/2005 05:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.7 0.4 69 15 300 300 -9.1 0 -8.9 -9.1 11/02/2005 05:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 49 23 300 300 -9 0 -8.7 -9.1 11/02/2005 05:40:00 0.4 0 0.7 0.4 0.4 0 0.4 0.4 0.4 0.1 0.7 0.4 58 13 100 300 -9 0 -8.7 -9.1 11/02/2005 05:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 62 0 300 300 -8.8 0 -8.7 -8.9 11/02/2005 06:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 62 0 300 300 -8.8 0 -8.7 -8.9 11/02/2005 06:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 62 0 300 300 -9 0 -8.9 -8.9 11/02/2005 06:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 44 21 300 300 -9 0 -8.9 -8.9 11/02/2005 06:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.7 0.4 86 30 300 300 -8.8 0 -8.7 -8.9 11/02/2005 06:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.7 0.4 119 2 300 300 -8.6 0 -8.5 -8.7 11/02/2005 06:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 128 0 300 300 -8.7 0 -8.5 -8.7 11/02/2005 07:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 128 0 300 300 -8.7 0 -8.7 -8.7 11/02/2005 07:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 127 0 300 300 -8.8 0 -8.7 -8.9 11/02/2005 07:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 127 0 300 300 -8.9 0 -8.7 -8.9 11/02/2005 07:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 129 0 300 300 -8.9 0 -8.7 -8.9 11/02/2005 07:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 129 0 300 300 -8.7 0 -8.7 -8.9 11/02/2005 07:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 129 0 300 300 -8.7 0 -8.7 -8.9 11/02/2005 08:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 129 0 300 300 -8.9 0 -8.7 -8.9 11/02/2005 08:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 129 0 300 300 -9 0 -8.9 -9.1 11/02/2005 08:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 129 0 300 300 -9.1 0 -8.9 -9.1 11/02/2005 08:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 105 28 300 300 -9.2 0 -8.9 -9.3 11/02/2005 08:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 70 0 300 300 -9.1 0.1 -8.9 -9.3 11/02/2005 08:50:00 0.4 0 0.7 0.4 0.4 0 0.4 0.4 0.4 0.1 0.7 0.4 28 30 359 300 -9 0.1 -8.9 -9.3 11/02/2005 09:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 6 0 300 300 -9.2 0 -8.9 -9.3 11/02/2005 09:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 337 23 300 300 -9 0 -8.9 -9.1 11/02/2005 09:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 243 82 300 300 -8.8 0 -8.7 -8.9 11/02/2005 09:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 188 35 300 300 -8.7 0 -8.5 -8.9 11/02/2005 09:40:00 0.4 0 0.7 0.4 0.4 0 0.4 0.4 0.4 0.1 0.7 0.4 199 15 192 300 -8.6 0 -8.5 -8.7 11/02/2005 09:50:00 0.4 0.1 1.1 0.4 0.4 0 0.7 0.4 0.4 0 0.7 0.4 170 13 185 300 -8.5 0 -8.3 -8.7 11/02/2005 10:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 173 17 300 300 -8.3 0 -8.1 -8.5 11/02/2005 10:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 190 12 300 300 -8.3 0 -8.1 -8.3 11/02/2005 10:20:00 0.4 0 0.7 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 205 39 191 300 -8.3 0 -8.1 -8.5 11/02/2005 10:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 226 16 300 300 -8.2 0 -8.1 -8.3 11/02/2005 10:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 193 27 300 300 -8.2 0 -8.1 -8.3 11/02/2005 10:50:00 0.4 0 0.7 0.4 0.4 0 0.4 0.4 0.4 0.1 0.7 0.4 175 23 137 300 -8.2 0 -8.1 -8.3 11/02/2005 11:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 223 27 300 300 -8.2 0 -8.1 -8.5 11/02/2005 11:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 220 35 300 300 -8.2 0 -8.1 -8.3 11/02/2005 11:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.7 0.4 163 10 300 300 -8.2 0 -8.1 -8.3 11/02/2005 11:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 171 7 300 300 -8.2 0 -8.1 -8.3 11/02/2005 11:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.7 0.4 195 22 300 300 -8.2 0 -8.1 -8.3 11/02/2005 11:50:00 0.4 0.1 1.1 0.4 0.4 0 0.4 0.4 0.4 0.1 0.7 0.4 222 18 192 300 -8.2 0 -8.1 -8.3 11/02/2005 12:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 251 11 300 300 -8 0.1 -7.6 -8.3 11/02/2005 12:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 197 13 300 300 -7.8 0 -7.6 -7.9 11/02/2005 12:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 184 3 300 300 -7.8 0 -7.6 -7.9 11/02/2005 12:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 236 10 300 300 -7.7 0 -7.4 -7.9 11/02/2005 12:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 235 24 300 300 -7.5 0 -7.2 -7.6 11/02/2005 12:50:00 0.4 0 0.7 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 221 29 176 300 -7.4 0.1 -7 -7.6 11/02/2005 13:00:00 0.4 0.1 0.7 0.4 0.4 0 0.4 0.4 0.4 0 0.7 0.4 193 19 198 300 -7.6 0 -7.4 -7.6 11/02/2005 13:10:00 0.4 0.1 1.1 0.4 0.4 0 0.7 0.4 0.4 0.2 1.1 0.4 218 9 201 300 -7.6 0 -7.4 -7.9 11/02/2005 13:20:00 0.4 0.1 0.7 0.4 0.4 0 0.4 0.4 0.4 0.1 0.7 0.4 192 17 197 300 -7.5 0 -7.2 -7.6 11/02/2005 13:30:00 0.4 0.1 0.7 0.4 0.4 0 0.4 0.4 0.4 0.1 0.7 0.4 187 18 171 300 -7.3 0 -7.2 -7.4 11/02/2005 13:40:00 0.4 0.2 1.1 0.4 0.4 0.1 1.1 0.4 0.4 0.2 1.1 0.4 153 14 140 300 -7.1 0 -7 -7.2 11/02/2005 13:50:00 0.5 0.2 1.1 0.4 0.4 0.1 1.1 0.4 0.5 0.3 1.5 0.4 185 39 164 300 -7.1 0 -7 -7.2 11/02/2005 14:00:00 0.4 0.1 0.7 0.4 0.4 0 0.4 0.4 0.4 0.1 1.1 0.4 214 27 205 300 -7.1 0 -6.8 -7.2 11/02/2005 14:10:00 0.4 0.1 0.7 0.4 0.4 0 0.7 0.4 0.4 0.1 1.1 0.4 203 29 169 300 -7.1 0 -7 -7.2 11/02/2005 14:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 228 13 300 300 -7.1 0 -7 -7.2 11/02/2005 14:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.7 0.4 232 17 300 300 -6.9 0 -6.6 -7 11/02/2005 14:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 240 11 300 300 -7 0 -6.8 -7 11/02/2005 14:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 200 30 300 300 -6.7 0 -6.6 -7 11/02/2005 15:00:00 0.4 0 0.7 0.4 0.4 0 0.4 0.4 0.4 0 0.7 0.4 231 10 249 300 -6.7 0 -6.6 -6.8 11/02/2005 15:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 246 4 300 300 -6.7 0 -6.6 -6.8 11/02/2005 15:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 242 0 300 300 -6.7 0 -6.6 -6.8 11/02/2005 15:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 218 30 300 300 -6.7 0 -6.6 -6.8 11/02/2005 15:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 155 3 300 300 -6.7 0 -6.6 -6.8 11/02/2005 15:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0.1 0.7 0.4 126 36 300 300 -6.6 0 -6.6 -6.8 11/02/2005 16:00:00 0.4 0 0.7 0.4 0.4 0 0.4 0.4 0.4 0.1 0.7 0.4 74 8 75 300 -6.6 0 -6.6 -6.8 11/02/2005 16:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.7 0.4 68 6 300 300 -6.7 0 -6.6 -6.8 11/02/2005 16:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 69 11 300 300 -6.8 0 -6.6 -6.8 11/02/2005 16:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.7 0.4 35 19 300 300 -7 0 -6.8 -7 11/02/2005 16:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 48 6 300 300 -7.3 0 -7 -7.4 11/02/2005 16:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0.1 0.7 0.4 41 2 300 300 -7.3 0 -7.2 -7.4 11/02/2005 17:00:00 0.4 0 0.7 0.4 0.4 0 0.4 0.4 0.4 0.1 0.7 0.4 40 4 46 300 -7.4 0 -7.2 -7.4 11/02/2005 17:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0.1 0.7 0.4 39 6 300 300 -7.4 0 -7.2 -7.6 11/02/2005 17:20:00 0.4 0 0.7 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 38 7 30 300 -7.5 0 -7.2 -7.6 11/02/2005 17:30:00 0.4 0.1 0.7 0.4 0.4 0 0.7 0.4 0.4 0.1 1.1 0.4 39 6 46 300 -7.5 0 -7.2 -7.6 11/02/2005 17:40:00 0.4 0 0.7 0.4 0.4 0 0.4 0.4 0.4 0 0.7 0.4 29 7 37 300 -7.5 0 -7.4 -7.6 11/02/2005 17:50:00 0.4 0 0.7 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 15 5 22 300 -7.5 0 -7.4 -7.6 11/02/2005 18:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.7 0.4 13 5 300 300 -7.6 0 -7.4 -7.6 11/02/2005 18:10:00 0.4 0 0.7 0.4 0.4 0 0.4 0.4 0.4 0.1 0.7 0.4 19 4 16 300 -7.6 0 -7.4 -7.6 11/02/2005 18:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.7 0.4 16 4 300 300 -7.6 0 -7.4 -7.6 11/02/2005 18:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 2 7 300 300 -7.6 0 -7.4 -7.6 11/02/2005 18:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 357 0 300 300 -7.5 0 -7.4 -7.6 11/02/2005 18:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 357 0 300 300 -7.5 0 -7.2 -7.6 11/02/2005 19:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 357 0 300 300 -7.6 0 -7.2 -7.6 11/02/2005 19:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 15 24 300 300 -7.6 0 -7.6 -7.6 11/02/2005 19:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 83 33 300 300 -7.6 0 -7.4 -7.6 11/02/2005 19:30:00 0.4 0 0.7 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 81 28 78 300 -7.6 0 -7.4 -7.6 11/02/2005 19:40:00 0.4 0 0.7 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 30 22 30 300 -7.6 0 -7.4 -7.6 11/02/2005 19:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 35 12 300 300 -7.6 0 -7.6 -7.6 11/02/2005 20:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.7 0.4 69 13 300 300 -7.8 0 -7.6 -7.9 11/02/2005 20:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 68 26 300 300 -7.9 0 -7.6 -8.1 11/02/2005 20:20:00 0.4 0 0.7 0.4 0.4 0 0.4 0.4 0.4 0 0.7 0.4 70 27 100 300 -8 0 -7.9 -8.1 11/02/2005 20:30:00 0.4 0.1 0.7 0.4 0.4 0 0.7 0.4 0.4 0.1 0.7 0.4 44 18 59 300 -8 0 -7.9 -8.1 11/02/2005 20:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 61 17 300 300 -8.2 0 -8.1 -8.1 11/02/2005 20:50:00 0.4 0.1 0.7 0.4 0.4 0 0.7 0.4 0.4 0.1 0.7 0.4 25 38 46 300 -8.2 0 -8.1 -8.3 11/02/2005 21:00:00 0.4 0.1 0.7 0.4 0.4 0 0.7 0.4 0.4 0.2 1.1 0.4 27 18 41 300 -8.4 0.1 -8.3 -8.7 11/02/2005 21:10:00 0.4 0.1 0.7 0.4 0.4 0 0.7 0.4 0.4 0.1 0.7 0.4 26 33 6 300 -8.7 0 -8.5 -8.9 11/02/2005 21:20:00 0.6 0.3 1.1 0.4 0.4 0.2 1.1 0.4 0.5 0.2 1.1 0.4 47 20 47 300 -8.8 0 -8.7 -8.9 11/02/2005 21:30:00 0.7 0.3 1.5 0.4 0.5 0.2 1.1 0.4 0.6 0.3 1.5 0.4 48 11 60 300 -9.1 0.1 -8.9 -9.3 11/02/2005 21:40:00 0.4 0.1 1.1 0.4 0.4 0 0.4 0.4 0.4 0 0.7 0.4 25 22 36 300 -9.2 0 -8.9 -9.3 11/02/2005 21:50:00 0.5 0.2 1.1 0.4 0.4 0.1 0.7 0.4 0.5 0.2 1.1 0.4 13 9 17 300 -9.1 0 -8.9 -9.1 11/02/2005 22:00:00 0.4 0.2 1.1 0.4 0.4 0.1 0.7 0.4 0.4 0.2 1.1 0.4 2 16 8 300 -9.1 0 -8.9 -9.3 11/02/2005 22:10:00 0.4 0.1 0.7 0.4 0.4 0 0.4 0.4 0.4 0.1 1.1 0.4 351 12 340 300 -9.1 0 -8.9 -9.3 11/02/2005 22:20:00 0.4 0 0.7 0.4 0.4 0 0.4 0.4 0.4 0.1 0.7 0.4 349 11 2 300 -9.1 0 -8.9 -9.1 11/02/2005 22:30:00 0.4 0 0.7 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 19 23 24 300 -9.1 0 -8.9 -9.3 11/02/2005 22:40:00 0.4 0.1 1.1 0.4 0.4 0.1 0.7 0.4 0.4 0.1 1.1 0.4 48 29 65 300 -9 0 -8.9 -9.1 11/02/2005 22:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 31 32 300 300 -8.9 0 -8.7 -8.9 11/02/2005 23:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 352 5 300 300 -9.1 0 -8.9 -9.3 11/02/2005 23:10:00 0.4 0 0.7 0.4 0.4 0 0.4 0.4 0.4 0.1 0.7 0.4 23 21 27 300 -9.1 0.1 -8.9 -9.3 11/02/2005 23:20:00 0.4 0 0.7 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 65 51 118 300 -9 0 -8.9 -9.1 11/02/2005 23:30:00 0.4 0.1 0.7 0.4 0.4 0 0.7 0.4 0.4 0.1 1.1 0.4 12 8 11 300 -9 0 -8.9 -9.1 11/02/2005 23:40:00 0.5 0.2 1.1 0.4 0.4 0.1 0.7 0.4 0.4 0.2 1.1 0.4 27 18 45 300 -9.1 0 -9.1 -9.3 11/02/2005 23:50:00 0.4 0.1 1.1 0.4 0.4 0 0.7 0.4 0.4 0.1 1.1 0.4 30 20 61 300 -9.2 0 -9.1 -9.3 11/03/2005 00:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 40 21 300 300 -9.3 0 -9.3 -9.3 11/03/2005 00:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 26 23 300 300 -9.5 0.1 -9.3 -9.7 11/03/2005 00:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 24 4 300 300 -9.8 0 -9.7 -10 11/03/2005 00:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.7 0.4 13 19 300 300 -10.1 0.1 -9.7 -10.4 11/03/2005 00:40:00 0.4 0 0.7 0.4 0.4 0 0.4 0.4 0.4 0.1 0.7 0.4 12 9 11 300 -10.3 0 -10.2 -10.6 11/03/2005 00:50:00 0.4 0 0.7 0.4 0.4 0 0.4 0.4 0.5 0.2 1.1 0.4 22 8 22 300 -10.5 0 -10.4 -10.6 11/03/2005 01:00:00 0.4 0 0.7 0.4 0.4 0 0.4 0.4 0.4 0.1 0.7 0.4 33 7 41 300 -10.5 0 -10.6 -10.6 11/03/2005 01:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0.1 0.7 0.4 16 9 300 300 -10.5 0 -10.4 -10.6 11/03/2005 01:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 12 12 300 300 -10.5 0 -10.4 -10.6 11/03/2005 01:30:00 0.5 0.2 1.1 0.4 0.4 0.1 0.7 0.4 0.4 0.1 0.7 0.4 359 11 4 300 -10.7 0 -10.6 -10.8 11/03/2005 01:40:00 0.4 0 0.7 0.4 0.4 0 0.4 0.4 0.4 0 0.7 0.4 10 22 48 300 -10.7 0 -10.6 -10.8 11/03/2005 01:50:00 0.4 0.1 0.7 0.4 0.4 0 0.7 0.4 0.4 0 0.4 0.4 21 8 21 300 -10.8 0 -10.6 -11 11/03/2005 02:00:00 0.4 0.1 0.7 0.4 0.4 0 0.4 0.4 0.4 0.1 0.7 0.4 18 9 19 300 -10.9 0 -10.8 -11 11/03/2005 02:10:00 0.4 0.1 0.7 0.4 0.4 0 0.7 0.4 0.4 0.1 1.1 0.4 12 17 22 300 -11.1 0 -11 -11.2 11/03/2005 02:20:00 0.4 0.2 1.1 0.4 0.4 0 0.7 0.4 0.4 0 0.7 0.4 350 7 350 300 -11.2 0 -11 -11.4 11/03/2005 02:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 4 9 300 300 -11.4 0 -11.4 -11.4 11/03/2005 02:40:00 0.4 0.2 1.1 0.4 0.4 0.1 0.7 0.4 0.4 0.1 0.7 0.4 7 12 18 300 -11.5 0 -11.4 -11.4 11/03/2005 02:50:00 0.4 0.1 0.7 0.4 0.4 0 0.7 0.4 0.4 0 0.7 0.4 10 18 5 300 -11.3 0 -11 -11.4 11/03/2005 03:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 356 10 300 300 -11.1 0 -11 -11.2 11/03/2005 03:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 5 13 300 300 -11.1 0 -11 -11.2 11/03/2005 03:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 5 22 300 300 -11.1 0 -11 -11.2 11/03/2005 03:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.7 0.4 347 8 300 300 -11.2 0 -11 -11.2 11/03/2005 03:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0.1 1.1 0.4 349 14 300 300 -11.1 0 -11 -11.2 11/03/2005 03:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.7 0.4 8 19 300 300 -11.1 0 -11 -11.2 11/03/2005 04:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0.1 0.7 0.4 63 14 300 300 -10.9 0 -11 -11 11/03/2005 04:10:00 0.4 0 0.7 0.4 0.4 0 0.4 0.4 0.4 0.1 0.7 0.4 40 7 35 300 -11.1 0 -11 -11.4 11/03/2005 04:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 46 8 300 300 -11.2 0 -11 -11.4 11/03/2005 04:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 87 13 300 300 -11.2 0 -11 -11.4 11/03/2005 04:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.7 0.4 59 9 300 300 -11.1 0 -11 -11.4 11/03/2005 04:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 43 19 300 300 -11.1 0 -11 -11.2 11/03/2005 05:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 26 9 300 300 -11 0 -11 -11.2 11/03/2005 05:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 29 16 300 300 -10.9 0 -10.8 -11 11/03/2005 05:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 346 5 300 300 -10.9 0 -10.8 -11 11/03/2005 05:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.7 0.4 342 9 300 300 -10.9 0 -11 -11 11/03/2005 05:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 5 32 300 300 -10.9 0 -11 -11 11/03/2005 05:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.7 0.4 20 8 300 300 -10.9 0 -11 -11 11/03/2005 06:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 22 1 300 300 -10.9 0 -10.8 -11 11/03/2005 06:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 21 0 300 300 -10.8 0 -10.6 -11 11/03/2005 06:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 21 0 300 300 -10.7 0 -10.6 -10.8 11/03/2005 06:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 348 21 300 300 -10.5 0 -10.4 -10.6 11/03/2005 06:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 317 0 300 300 -10.4 0 -10.4 -10.6 11/03/2005 06:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 317 0 300 300 -10.4 0 -10.4 -10.6 11/03/2005 07:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 317 0 300 300 -10.5 0 -10.4 -10.6 11/03/2005 07:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 317 0 300 300 -10.6 0 -10.6 -10.8 11/03/2005 07:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 26 39 300 300 -10.7 0 -10.6 -10.8 11/03/2005 07:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 113 18 300 300 -10.7 0 -10.6 -10.8 11/03/2005 07:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 130 0 300 300 -10.7 0 -10.6 -10.8 11/03/2005 07:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 130 0 300 300 -10.6 0 -10.6 -10.8 11/03/2005 08:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 189 47 300 300 -10.5 0 -10.4 -10.6 11/03/2005 08:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 192 13 300 300 -10.5 0 -10.4 -10.6 11/03/2005 08:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 169 30 300 300 -10.5 0 -10.4 -10.6 11/03/2005 08:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 175 33 300 300 -10.5 0 -10.4 -10.6 11/03/2005 08:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 225 36 300 300 -10.6 0 -10.4 -10.8 11/03/2005 08:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 290 8 300 300 -10.9 0 -10.6 -11 11/03/2005 09:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 290 0 300 300 -10.9 0 -11 -11 11/03/2005 09:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 282 6 300 300 -10.9 0 -10.8 -11 11/03/2005 09:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 298 0 300 300 -10.8 0 -10.6 -11 11/03/2005 09:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 305 7 300 300 -10.6 0 -10.6 -10.8 11/03/2005 09:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 307 5 300 300 -10.6 0 -10.6 -10.6 11/03/2005 09:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 297 4 300 300 -10.7 0 -10.6 -11 11/03/2005 10:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 298 5 300 300 -10.6 0 -10.6 -11 11/03/2005 10:10:00 0.4 0.1 0.7 0.4 0.4 0 0.4 0.4 0.4 0.1 0.7 0.4 311 11 315 300 -10.4 0 -10.4 -10.6 11/03/2005 10:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 311 4 300 300 -10.3 0 -10.2 -10.4 11/03/2005 10:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.7 0.4 304 5 300 300 -10.4 0 -10.2 -10.4 11/03/2005 10:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 306 7 300 300 -10.3 0 -10.2 -10.4 11/03/2005 10:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 321 15 300 300 -10.2 0 -10.2 -10.2 11/03/2005 11:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 314 11 300 300 -10.1 0 -10 -10.2 11/03/2005 11:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 310 7 300 300 -9.9 0.1 -9.5 -10.2 11/03/2005 11:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 286 11 300 300 -9.6 0 -9.5 -9.7 11/03/2005 11:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 286 10 300 300 -9.6 0 -9.5 -9.7 11/03/2005 11:40:00 0.4 0 0.7 0.4 0.4 0 0.4 0.4 0.4 0.1 0.7 0.4 295 7 302 300 -9.6 0 -9.3 -9.7 11/03/2005 11:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0.1 0.7 0.4 280 13 300 300 -9.8 0 -9.7 -10 11/03/2005 12:00:00 0.4 0.1 0.7 0.4 0.4 0 0.4 0.4 0.4 0.1 0.7 0.4 264 9 265 300 -9.8 0 -9.7 -10 11/03/2005 12:10:00 0.4 0 0.7 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 258 10 257 300 -9.7 0 -9.5 -9.7 11/03/2005 12:20:00 0.4 0 0.7 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 251 9 241 300 -9.7 0 -9.5 -9.7 11/03/2005 12:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.7 0.4 262 8 300 300 -9.8 0 -9.7 -9.7 11/03/2005 12:40:00 0.4 0.1 1.1 0.4 0.4 0 0.4 0.4 0.4 0.2 1.5 0.4 222 22 217 300 -9.7 0 -9.5 -9.7 11/03/2005 12:50:00 0.4 0.1 1.1 0.4 0.4 0 0.4 0.4 0.4 0.1 1.1 0.4 253 39 300 300 -9.5 0 -9.3 -9.7 11/03/2005 13:00:00 0.4 0.2 1.1 0.4 0.4 0 0.4 0.4 0.5 0.3 1.5 0.4 300 11 279 300 -9.6 0 -9.5 -9.7 11/03/2005 13:10:00 0.4 0.1 0.7 0.4 0.4 0 0.4 0.4 0.4 0.1 1.1 0.4 333 13 343 300 -9.4 0 -9.3 -9.7 11/03/2005 13:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 352 9 300 300 -9.2 0.1 -8.9 -9.3 11/03/2005 13:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 21 17 300 300 -9 0 -8.9 -8.9 11/03/2005 13:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0.1 0.7 0.4 19 11 300 300 -8.9 0 -8.9 -8.9 11/03/2005 13:50:00 0.4 0 0.7 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 22 19 342 300 -8.8 0 -8.5 -8.9 11/03/2005 14:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 39 8 300 300 -8.5 0 -8.5 -8.7 11/03/2005 14:10:00 0.4 0 0.7 0.4 0.4 0 0.4 0.4 0.4 0.1 0.7 0.4 40 18 39 300 -8.3 0 -8.1 -8.5 11/03/2005 14:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 4 13 300 300 -8.1 0 -7.9 -8.3 11/03/2005 14:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 29 26 300 300 -8 0 -7.6 -8.1 11/03/2005 14:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 56 0 300 300 -7.7 0 -7.6 -7.9 11/03/2005 14:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 59 5 300 300 -7.6 0 -7.6 -7.6 11/03/2005 15:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 65 1 300 300 -7.6 0 -7.4 -7.6 11/03/2005 15:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 55 4 300 300 -7.6 0 -7.4 -7.6 11/03/2005 15:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 54 7 300 300 -7.6 0 -7.4 -7.6 11/03/2005 15:30:00 0.4 0 0.7 0.4 0.4 0 0.4 0.4 0.4 0 0.7 0.4 79 8 75 300 -7.4 0 -7.2 -7.6 11/03/2005 15:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 102 22 300 300 -7.4 0 -7.2 -7.4 11/03/2005 15:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 89 0 300 300 -7.4 0 -7.2 -7.4 11/03/2005 16:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 89 0 300 300 -7.4 0 -7.2 -7.4 11/03/2005 16:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 89 0 300 300 -7.5 0 -7.2 -7.4 11/03/2005 16:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 89 0 300 300 -7.5 0 -7.2 -7.6 11/03/2005 16:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 89 0 300 300 -7.7 0 -7.4 -7.9 11/03/2005 16:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 89 0 300 300 -8 0.1 -7.6 -8.1 11/03/2005 16:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 89 0 300 300 -8.4 0.2 -8.1 -8.7 11/03/2005 17:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 89 0 300 300 -8.9 0.1 -8.7 -9.1 11/03/2005 17:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 89 0 300 300 -9.1 0 -8.9 -9.3 11/03/2005 17:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 89 0 300 300 -9.4 0.1 -9.3 -9.7 11/03/2005 17:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 89 0 300 300 -9.6 0 -9.5 -9.7 11/03/2005 17:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 89 0 300 300 -9.7 0 -9.5 -10 11/03/2005 17:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 89 0 300 300 -10 0 -9.7 -10.2 11/03/2005 18:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 89 0 300 300 -10.4 0 -10 -10.6 11/03/2005 18:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 89 0 300 300 -10.5 0 -10.4 -10.8 11/03/2005 18:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 89 0 300 300 -10.8 0 -10.6 -11 11/03/2005 18:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.7 0.4 290 86 300 300 -10.9 0 -11 -11.2 11/03/2005 18:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 246 8 300 300 -11 0 -10.8 -11.2 11/03/2005 18:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 252 9 300 300 -11.3 0.1 -11 -11.4 11/03/2005 19:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 227 1 300 300 -11.5 0 -11.2 -11.6 11/03/2005 19:10:00 0.4 0 0.7 0.4 0.4 0 0.4 0.4 0.4 0.2 1.1 0.4 243 9 229 300 -11.1 0.2 -10.8 -11.4 11/03/2005 19:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 240 5 300 300 -11.3 0.2 -11 -11.6 11/03/2005 19:30:00 0.5 0.2 1.1 0.4 0.4 0 0.4 0.4 0.5 0.2 1.1 0.4 265 20 286 300 -11.7 0.1 -11.4 -12 11/03/2005 19:40:00 0.4 0.1 1.1 0.4 0.4 0 0.4 0.4 0.7 0.3 1.1 0.4 291 5 297 300 -11.8 0.1 -11.4 -12 11/03/2005 19:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 263 33 300 300 -11.9 0.1 -11.6 -12.2 11/03/2005 20:00:00 0.4 0 0.7 0.4 0.4 0 0.4 0.4 0.4 0 0.7 0.4 217 14 241 300 -12.3 0 -12.2 -12.4 11/03/2005 20:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 253 11 300 300 -12.4 0 -12.2 -12.6 11/03/2005 20:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.7 0.4 295 8 300 300 -12.5 0 -12.4 -12.6 11/03/2005 20:30:00 0.4 0 0.7 0.4 0.4 0 0.4 0.4 0.5 0.2 1.1 0.4 5 28 45 300 -12.6 0 -12.6 -12.8 11/03/2005 20:40:00 0.4 0 0.7 0.4 0.4 0 0.4 0.4 0.4 0 0.7 0.4 53 29 48 300 -12.8 0 -12.6 -13 11/03/2005 20:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 66 5 300 300 -12.6 0.1 -12.4 -13 11/03/2005 21:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0.1 1.1 0.4 63 4 300 300 -12.7 0 -12.6 -13 11/03/2005 21:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.5 0.2 1.1 0.4 56 1 300 300 -12.6 0.3 -12.2 -13.2 11/03/2005 21:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.8 0.3 1.5 0.4 50 10 300 300 -12.7 0.2 -12.2 -13.2 11/03/2005 21:30:00 0.4 0 0.7 0.4 0.4 0 0.4 0.4 0.4 0.1 0.7 0.4 47 8 27 300 -13.2 0.2 -12.6 -13.6 11/03/2005 21:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 11 64 300 300 -13.1 0.2 -12.6 -13.6 11/03/2005 21:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.5 0.3 1.9 0.4 246 66 300 300 -12.5 0 -12.2 -12.6 11/03/2005 22:00:00 0.4 0.2 1.1 0.4 0.4 0 0.4 0.4 0.8 0.5 1.9 0.4 252 29 288 300 -12.8 0 -12.6 -13.2 11/03/2005 22:10:00 0.4 0.2 1.5 0.4 0.4 0 0.4 0.4 0.6 0.4 1.9 0.4 216 82 279 300 -12.1 0.4 -11.4 -12.6 11/03/2005 22:20:00 0.4 0 0.7 0.4 0.4 0 0.4 0.4 0.4 0.2 1.1 0.4 240 27 271 300 -12 0 -11.8 -12.2 11/03/2005 22:30:00 0.5 0.3 1.5 0.4 0.4 0 0.4 0.4 0.5 0.2 1.5 0.4 19 29 6 300 -12.2 0.1 -12 -12.4 11/03/2005 22:40:00 2.1 0.9 4.2 0.4 1.7 1 3.8 0.4 0.8 0.5 1.9 0.4 16 19 26 300 -12.1 0.4 -11.4 -12.6 11/03/2005 22:50:00 0.7 0.6 2.6 0.4 0.6 0.4 2.6 0.4 0.4 0 0.7 0.4 315 53 310 300 -10.5 0.3 -10.2 -11.4 11/03/2005 23:00:00 1.1 0.5 2.3 0.4 0.8 0.5 2.3 0.4 0.5 0.3 1.5 0.4 95 69 165 300 -10.6 0.3 -10.4 -11.4 11/03/2005 23:10:00 0.7 0.5 2.6 0.4 0.5 0.3 2.3 0.4 0.4 0 0.4 0.4 36 29 2 300 -11.1 0.1 -10.8 -11.4 11/03/2005 23:20:00 0.7 0.4 1.5 0.4 0.4 0.2 1.1 0.4 0.4 0.1 1.1 0.4 70 86 13 300 -10 0.4 -9.5 -10.8 11/03/2005 23:30:00 1.3 0.8 3.4 0.4 0.9 0.8 3 0.4 0.4 0.2 1.9 0.4 344 29 351 300 -9.8 0 -9.7 -10.2 11/03/2005 23:40:00 3.4 0.7 4.9 1.1 3 0.8 4.9 0.7 1.8 0.7 3.4 0.4 353 12 347 300 -9.8 0.4 -9.1 -10.4 11/03/2005 23:50:00 3.9 1 6.5 1.1 3.7 1.1 6.5 0.7 2.7 1.1 5.3 0.4 355 15 346 300 -8.8 0.1 -8.5 -9.1 11/04/2005 00:00:00 4.6 1 8 2.6 4.5 1 8 2.3 3.5 0.9 6.5 1.5 356 9 342 300 -8.8 0.1 -8.5 -9.1 11/04/2005 00:10:00 5.8 0.9 9.5 3.4 5.8 1 9.1 2.3 4.5 1.1 8.8 1.9 4 12 355 300 -8.4 0.1 -8.1 -8.7 11/04/2005 00:20:00 5 1 8.4 1.9 5 1 8 2.3 4.2 1.1 6.8 1.9 357 9 11 300 -8.2 0 -8.1 -8.3 11/04/2005 00:30:00 5.3 0.8 7.6 2.3 5.3 1 7.2 1.9 4.3 1.1 6.8 1.5 359 11 23 300 -8.2 0 -8.1 -8.5 11/04/2005 00:40:00 5.8 1.4 9.5 3 5.6 1.5 9.5 1.9 4.8 1.4 8.4 1.9 12 17 30 300 -7.9 0.2 -7.6 -8.3 11/04/2005 00:50:00 5 1 7.6 3 5 1 8.4 1.9 4.2 0.9 7.2 1.9 2 11 9 300 -8 0.1 -7.6 -8.1 11/04/2005 01:00:00 5.2 1.1 8.8 2.6 5 1.1 9.1 2.3 4.2 1.2 7.6 1.5 7 12 26 300 -8 0 -7.9 -8.1 11/04/2005 01:10:00 3.7 0.7 5.7 2.3 3.6 0.8 5.7 1.9 3 0.7 4.9 1.5 1 9 5 300 -8.2 0 -8.1 -8.3 11/04/2005 01:20:00 2.9 0.7 4.9 1.5 2.7 0.8 4.9 0.7 2.3 0.7 4.2 0.4 9 16 20 300 -8.2 0 -8.1 -8.3 11/04/2005 01:30:00 3.4 1 6.8 1.1 3.1 1.1 6.5 1.1 2.4 1 5.3 0.4 14 23 351 300 -8.3 0 -8.1 -8.5 11/04/2005 01:40:00 3.4 0.8 6.1 1.5 3 0.9 5.3 0.7 2.6 0.7 4.9 1.1 23 14 16 300 -8.2 0 -8.1 -8.3 11/04/2005 01:50:00 3.1 1 5.3 0.7 2.7 1.1 5.3 0.4 2.2 1 4.6 0.4 28 18 22 300 -8.2 0 -8.1 -8.3 11/04/2005 02:00:00 4.7 1.1 7.2 1.5 4.2 1.2 7.2 0.7 3.2 1 6.1 0.7 26 15 46 300 -7.7 0.3 -7.4 -8.3 11/04/2005 02:10:00 4.5 1.1 7.2 2.3 4.2 1.2 7.2 1.9 3.4 1 6.5 1.9 21 15 30 300 -7.5 0.1 -7.2 -7.6 11/04/2005 02:20:00 5.6 1.1 9.1 3 5.2 1.2 9.1 2.6 4.2 1 7.6 2.3 15 11 17 300 -7.2 0 -7 -7.4 11/04/2005 02:30:00 6.4 1.2 9.9 3.4 5.9 1.3 9.5 3 4.9 1.2 8.4 1.5 24 15 1 300 -6.9 0 -6.8 -7 11/04/2005 02:40:00 5.5 1 8.4 3 4.9 1 8 2.6 4 1.1 7.6 1.1 30 12 27 300 -6.8 0 -6.6 -7 11/04/2005 02:50:00 4.8 1.2 8.4 2.3 4.4 1.2 7.2 1.5 3.6 1.1 6.5 1.5 23 16 11 300 -6.8 0 -6.6 -7 11/04/2005 03:00:00 6.1 1.6 9.9 2.6 5.8 1.7 10.7 2.3 5 1.5 9.5 1.9 10 15 11 300 -6.6 0 -6.4 -6.8 11/04/2005 03:10:00 6.5 1.5 10.7 3.4 6.3 1.5 10.3 2.6 5.5 1.5 9.5 2.3 8 15 21 300 -6.3 0 -6.1 -6.6 11/04/2005 03:20:00 6.9 1.4 10.7 2.6 6.8 1.6 11.1 2.3 5.8 1.6 10.3 1.9 7 13 355 300 -6.4 0 -6.1 -6.6 11/04/2005 03:30:00 7.6 1.8 13.7 3.4 7.6 2 14.1 3.4 6.5 1.9 12.2 3 1 14 7 300 -6.2 0 -5.9 -6.4 11/04/2005 03:40:00 7.8 1.8 12.6 3.8 7.8 1.9 12.6 3.4 6.7 1.8 11.1 3 1 13 10 300 -6.1 0 -5.9 -6.1 11/04/2005 03:50:00 7 1.8 11.5 3 6.9 2 11.8 2.6 5.7 1.7 10.7 1.9 8 14 6 300 -6.2 0 -6.1 -6.4 11/04/2005 04:00:00 6 1.6 9.9 2.3 5.8 1.7 9.5 1.9 4.9 1.7 10.3 0.7 9 18 15 300 -6.2 0 -6.1 -6.4 11/04/2005 04:10:00 6.2 1.3 9.9 3.4 6 1.5 9.9 3 5.2 1.3 9.1 2.3 6 17 20 300 -6.3 0 -6.1 -6.6 11/04/2005 04:20:00 4.9 1.5 9.9 2.3 4.7 1.7 10.3 1.9 3.8 1.5 8 1.1 11 17 13 300 -6.4 0.1 -6.1 -6.6 11/04/2005 04:30:00 4.8 1.2 8 2.3 4.5 1.2 8 1.9 3.6 1.2 7.2 1.1 16 15 350 300 -6.5 0 -6.4 -6.6 11/04/2005 04:40:00 4.4 1.6 9.9 1.1 4.2 1.5 9.1 0.7 3.5 1.4 8.4 0.7 26 21 20 300 -6.5 0 -6.6 -6.6 11/04/2005 04:50:00 3.6 1.1 6.5 1.1 3.3 1.1 6.8 1.1 2.6 1 6.1 1.1 33 23 1 300 -6.7 0.2 -6.6 -7 11/04/2005 05:00:00 3.6 1.2 6.5 1.1 3.4 1.3 6.5 0.4 2.9 1 5.7 0.7 26 20 23 300 -6.8 0 -6.6 -7 11/04/2005 05:10:00 4.5 1.3 8.8 1.9 4.2 1.3 8.8 1.9 3.4 1.1 8 0.7 29 17 4 300 -6.8 0 -6.8 -7 11/04/2005 05:20:00 5.4 2.1 10.3 1.5 5.1 2.1 11.1 1.5 4.2 1.9 8.8 0.4 23 21 24 300 -7 0 -6.8 -7.2 11/04/2005 05:30:00 6.6 1.6 9.9 3 6.2 1.6 10.3 2.6 5.1 1.5 9.1 1.9 23 19 20 300 -6.8 0 -6.6 -7 11/04/2005 05:40:00 6 1.5 10.7 3 5.6 1.4 11.1 2.3 4.6 1.2 9.5 1.9 30 17 12 300 -6.9 0 -6.8 -7 11/04/2005 05:50:00 5 1.3 9.5 2.3 4.7 1.4 9.5 1.9 3.9 1.2 7.2 1.5 31 17 10 300 -7.1 0 -6.8 -7 11/04/2005 06:00:00 5.1 1.7 9.9 1.5 4.9 1.7 10.3 1.1 4 1.4 8.4 1.1 40 20 17 300 -7 0 -6.8 -7 11/04/2005 06:10:00 4 1.7 9.1 0.4 3.9 1.7 8.8 0.4 3 1.3 7.6 0.4 49 24 17 300 -7.1 0 -6.8 -7.2 11/04/2005 06:20:00 3 1.3 6.5 0.4 2.9 1.2 6.1 0.4 2.4 1.1 5.7 0.4 51 36 111 300 -7.4 0.1 -7.2 -7.4 11/04/2005 06:30:00 2.5 1.2 6.1 0.4 2.5 1.2 6.1 0.4 2 0.9 4.6 0.4 76 35 70 300 -7.6 0 -7.2 -7.9 11/04/2005 06:40:00 1.5 1.2 6.8 0.4 1.3 1.2 6.5 0.4 1.2 1 5.3 0.4 79 61 50 300 -7.9 0 -7.6 -8.1 11/04/2005 06:50:00 1.5 1 4.9 0.4 1.4 0.9 4.6 0.4 1.4 0.8 3.4 0.4 119 72 0 300 -7.7 0 -7.6 -8.1 11/04/2005 07:00:00 4.2 1.7 8 0.4 3.9 1.7 7.6 0.4 3.2 1.5 6.8 0.4 42 22 44 300 -7.8 0.2 -7.4 -8.1 11/04/2005 07:10:00 3.8 1 6.5 1.1 3.5 1 6.5 0.7 2.8 1 6.1 0.7 34 29 24 300 -7.5 0 -7.2 -7.6 11/04/2005 07:20:00 6.1 1.4 9.5 2.6 5.7 1.4 9.5 2.3 4.8 1.5 8.8 1.1 29 17 17 300 -7.2 0.1 -7 -7.6 11/04/2005 07:30:00 5.4 1.5 9.5 0.7 5 1.4 8.4 0.7 4.1 1.4 8 0.7 25 17 40 300 -7.3 0 -7 -7.4 11/04/2005 07:40:00 4.5 1.3 8.8 1.5 4.2 1.3 8 1.1 3.5 1.1 6.5 0.4 20 20 19 300 -7.3 0 -7.2 -7.4 11/04/2005 07:50:00 5.3 1.4 10.3 2.3 4.9 1.4 10.7 1.5 4.3 1.3 9.1 1.5 18 16 358 300 -7.3 0 -7.2 -7.4 11/04/2005 08:00:00 5.3 1.6 10.7 1.9 5 1.5 11.1 1.9 4.2 1.4 9.5 1.9 19 22 14 300 -7.3 0 -7.2 -7.4 11/04/2005 08:10:00 7.7 2.2 13.3 2.6 7.1 2.1 14.1 2.3 5.8 1.9 11.5 1.9 24 15 14 300 -7.3 0 -7 -7.4 11/04/2005 08:20:00 7.9 1.7 13.3 4.2 7.4 1.7 11.8 3.8 6.3 1.6 11.5 2.6 20 15 21 300 -7.1 0 -7 -7.2 11/04/2005 08:30:00 6.5 1.7 9.9 3 6 1.7 10.7 2.3 5.1 1.5 9.9 2.3 25 15 52 300 -7.1 0 -6.8 -7.2 11/04/2005 08:40:00 5.9 1.6 10.3 1.9 5.5 1.6 10.7 1.9 4.5 1.4 8.8 1.5 33 18 35 300 -7.1 0 -6.8 -7.2 11/04/2005 08:50:00 7.3 1.9 12.6 2.3 7.1 2 11.8 2.3 5.7 1.7 11.1 1.1 35 17 39 300 -6.8 0 -6.6 -7 11/04/2005 09:00:00 7.2 1.7 13.7 3.8 6.8 1.7 13.7 2.6 5.5 1.5 9.9 2.3 28 16 43 300 -6.8 0 -6.6 -7 11/04/2005 09:10:00 7.4 1.9 12.6 2.6 6.8 1.8 12.6 3 5.6 1.6 11.5 2.6 23 13 28 300 -6.9 0 -6.8 -7 11/04/2005 09:20:00 6.3 1.3 11.5 3.8 5.7 1.3 11.5 3 4.8 1.2 9.5 1.9 25 12 40 300 -6.9 0 -6.8 -7 11/04/2005 09:30:00 5.5 1.5 8.8 1.9 5.1 1.5 9.1 1.5 4.3 1.3 9.1 1.5 23 16 9 300 -7.1 0 -6.8 -7 11/04/2005 09:40:00 5.9 1.3 9.5 2.6 5.4 1.3 9.1 1.9 4.6 1.1 7.6 2.3 24 17 33 300 -6.8 0 -6.6 -7 11/04/2005 09:50:00 7.6 2 12.6 3.4 7.2 2 13 3 5.7 1.8 11.8 1.5 31 18 9 300 -6.5 0 -6.4 -6.6 11/04/2005 10:00:00 7.3 2.1 12.6 1.9 7 2.2 12.6 1.5 5.8 1.8 12.2 1.9 37 15 73 300 -6.2 0 -6.1 -6.6 11/04/2005 10:10:00 6 1.7 11.1 2.3 5.7 1.7 11.1 1.9 4.6 1.7 10.3 1.1 36 20 36 300 -6 0 -5.9 -6.1 11/04/2005 10:20:00 6.6 2.2 11.8 1.5 6.3 2.2 12.2 1.5 5.4 2 10.3 0.7 43 21 31 300 -5.9 0 -5.7 -6.1 11/04/2005 10:30:00 6.2 1.7 11.5 2.3 5.8 1.7 10.7 2.3 5 1.7 11.8 1.5 38 22 24 300 -5.8 0 -5.7 -5.9 11/04/2005 10:40:00 8.2 2 13.7 2.6 7.9 2 14.1 3 6.6 1.8 12.6 2.3 33 21 14 300 -5.8 0 -5.7 -5.9 11/04/2005 10:50:00 9 2.2 14.5 3.4 8.4 2.1 14.5 2.6 7.1 1.9 11.8 1.9 29 14 46 300 -5.6 0 -5.5 -5.7 11/04/2005 11:00:00 8.3 2 13.3 3.8 7.8 2 13.7 3 6.6 1.9 14.9 2.3 28 19 27 300 -5.4 0.1 -5.3 -5.7 11/04/2005 11:10:00 8.3 2.2 14.1 3.8 7.9 2.3 14.1 3 6.8 2 12.6 2.3 28 18 31 300 -5.3 0 -5 -5.5 11/04/2005 11:20:00 8.9 2.1 15.3 3.4 8.3 2.1 16.1 3.8 7.4 1.8 12.2 2.3 31 16 51 300 -5 0 -5 -5.3 11/04/2005 11:30:00 10.4 2.6 16.1 3.4 9.8 2.5 16.4 3.4 8.3 2.2 14.1 3 27 16 44 300 -5 0 -4.8 -5 11/04/2005 11:40:00 8.9 2.4 15.6 2.6 8.3 2.3 15.6 2.6 7 2.1 13 2.6 29 18 31 300 -4.8 0 -4.6 -5 11/04/2005 11:50:00 9.8 2.6 16.4 4.2 9.3 2.5 16.8 3.8 7.9 2.5 16.1 3.4 27 18 47 300 -4.8 0 -4.6 -4.8 11/04/2005 12:00:00 9.6 2 15.6 3.4 9 2.1 15.6 2.6 7.4 2.1 13 1.9 28 17 56 300 -4.7 0 -4.4 -4.8 11/04/2005 12:10:00 10.7 2.4 16.8 5.7 10 2.3 16.4 4.9 8.6 2.3 15.6 3.8 27 15 18 300 -4.4 0 -4.4 -4.6 11/04/2005 12:20:00 10.5 2.5 17.6 5.3 9.9 2.5 16.8 4.6 8.3 2.2 15.6 3.8 30 17 9 300 -4.2 0 -3.9 -4.4 11/04/2005 12:30:00 8.8 1.8 14.1 4.6 8.2 1.9 13 4.2 7 1.7 13 2.6 27 15 32 300 -4 0.1 -3.7 -4.4 11/04/2005 12:40:00 9.4 2.7 16.1 2.6 8.9 2.7 15.3 2.3 7.9 2.6 15.3 3.4 22 18 22 300 -4 0 -3.7 -4.2 11/04/2005 12:50:00 8.3 2.5 15.3 3.4 7.9 2.5 16.1 2.6 6.6 2.2 13.3 2.6 23 19 5 300 -3.9 0 -3.5 -3.9 11/04/2005 13:00:00 8.2 2.4 13.3 2.3 7.9 2.5 13.7 2.3 6.8 2.4 13.3 2.6 17 19 23 300 -3.9 0 -3.7 -3.9 11/04/2005 13:10:00 8.4 1.8 13 3.4 8 1.8 13 3.4 6.8 1.6 12.6 3.4 14 17 29 300 -3.9 0 -3.9 -3.9 11/04/2005 13:20:00 7.5 2.4 13.7 1.5 7.2 2.5 14.5 1.5 6.3 2 13.3 1.9 15 20 0 300 -3.8 0 -3.7 -3.9 11/04/2005 13:30:00 7.8 1.8 14.5 3.8 7.3 1.9 14.5 3.4 6.4 1.7 12.2 2.6 19 19 22 300 -3.8 0 -3.7 -3.9 11/04/2005 13:40:00 7.9 1.8 13 4.2 7.4 1.8 12.6 3.4 6.2 1.6 11.5 2.3 17 15 39 300 -3.8 0 -3.7 -3.9 11/04/2005 13:50:00 7.7 2.5 14.5 3 7.3 2.6 14.9 2.3 6.4 2.2 12.6 1.5 15 17 12 300 -3.8 0 -3.7 -3.9 11/04/2005 14:00:00 8 1.8 14.1 4.2 7.3 1.7 13.7 3.8 6.4 1.6 11.5 2.6 21 13 30 300 -3.8 0 -3.7 -3.9 11/04/2005 14:10:00 8.3 2.1 14.1 3.4 8 2.3 14.1 3 6.8 2 14.5 3 21 19 41 300 -3.8 0 -3.7 -3.9 11/04/2005 14:20:00 7.9 1.8 12.2 3.4 7.4 1.7 11.8 2.6 6.4 1.6 11.8 3 13 17 32 300 -3.9 0 -3.7 -3.9 11/04/2005 14:30:00 8.3 2.4 15.3 3 8 2.4 14.9 2.6 7 2.1 12.6 2.6 12 16 25 300 -3.9 0 -3.7 -3.9 11/04/2005 14:40:00 7.8 2.2 13.7 2.6 7.5 2.3 13.7 2.3 6.6 2.3 12.6 2.6 15 17 23 300 -3.9 0 -3.9 -3.9 11/04/2005 14:50:00 7.6 2 12.6 2.3 7.4 2.1 13 1.9 6.2 2 12.6 2.3 15 21 22 300 -4 0 -3.9 -4.2 11/04/2005 15:00:00 7.7 2 12.6 3.8 7.4 2.1 13.3 3.4 6.3 1.8 11.8 2.6 11 17 17 300 -4.2 0 -3.9 -4.4 11/04/2005 15:10:00 7.3 2 14.5 3.4 7.1 2 14.5 3 6.1 1.7 12.2 2.3 9 18 16 300 -4.3 0 -4.4 -4.6 11/04/2005 15:20:00 8.2 2 13 3.8 8 2.1 13.3 3 6.8 1.9 11.1 2.6 7 17 352 300 -4.7 0 -4.4 -4.8 11/04/2005 15:30:00 8.9 1.7 14.9 4.2 8.7 1.9 15.3 3.8 7.2 1.7 11.8 3 11 15 13 300 -4.8 0 -4.6 -4.8 11/04/2005 15:40:00 7.7 1.6 12.2 3.4 7.6 1.7 12.6 3 6.5 1.7 11.8 2.6 5 15 3 300 -4.9 0 -4.8 -5 11/04/2005 15:50:00 7.4 1.8 12.2 3 7.3 2 12.6 2.6 6.4 1.7 11.5 2.6 0 16 349 300 -5.1 0.1 -4.8 -5.3 11/04/2005 16:00:00 8.3 1.7 12.6 4.6 8.2 1.7 13 4.2 7.3 1.7 11.8 3.8 2 16 0 300 -5.3 0 -5 -5.5 11/04/2005 16:10:00 7.3 1.7 13 3.8 7.2 1.9 13.3 3.8 6.1 1.7 12.6 1.9 359 15 351 300 -5.6 0.1 -5.5 -5.7 11/04/2005 16:20:00 7.4 1.7 13 4.2 7.4 1.7 13.7 4.2 6.7 1.7 11.1 2.6 359 13 9 300 -5.9 0 -5.7 -5.9 11/04/2005 16:30:00 7.3 1.7 12.2 3 7.3 1.7 11.8 3.4 6.3 1.6 10.7 2.6 2 17 19 300 -6 0 -5.7 -6.1 11/04/2005 16:40:00 7.6 1.7 11.8 3.4 7.5 1.7 11.8 3 6.7 1.7 10.7 2.6 3 15 25 300 -6.1 0 -5.9 -6.1 11/04/2005 16:50:00 7.4 1.8 13.3 2.6 7.4 1.9 13.7 3 6.6 1.9 13.7 2.6 2 14 354 300 -6.2 0 -6.1 -6.4 11/04/2005 17:00:00 7.8 2.1 13.7 3.8 7.6 2.1 14.9 3.4 6.7 1.7 13 2.6 6 16 4 300 -6.2 0 -6.1 -6.4 11/04/2005 17:10:00 7.9 2 14.1 3.4 7.7 2.1 14.5 2.6 6.4 1.7 13.3 2.3 7 17 353 300 -6.5 0 -6.1 -6.6 11/04/2005 17:20:00 9.1 2.2 16.1 3.8 8.9 2.4 16.1 3.8 7.4 2.3 14.1 3 8 14 4 300 -6.5 0 -6.4 -6.6 11/04/2005 17:30:00 8.4 2.4 14.5 4.2 8.3 2.4 14.9 4.2 6.8 2.3 13.7 2.6 2 14 16 300 -6.6 0 -6.6 -6.8 11/04/2005 17:40:00 8.1 1.9 14.9 4.2 7.8 1.9 12.6 3.4 6.8 1.6 11.8 3.4 4 17 22 300 -6.8 0 -6.6 -7 11/04/2005 17:50:00 8.3 2.2 14.5 3 8.2 2.3 14.1 1.9 6.9 2.2 14.5 2.6 5 16 4 300 -6.8 0 -6.6 -6.8 11/04/2005 18:00:00 8.1 1.5 13.3 4.9 8.1 1.7 13.3 4.2 7.1 1.5 12.6 3.8 3 14 358 300 -6.9 0.1 -6.8 -7 11/04/2005 18:10:00 7.9 1.7 12.6 4.2 7.9 1.8 13 3.8 6.7 1.8 11.8 2.6 0 13 358 300 -7.1 0 -7 -7 11/04/2005 18:20:00 8.6 2.2 15.3 3 8.6 2.4 15.6 2.3 7.3 2.4 14.9 2.6 3 15 351 300 -7.1 0 -7 -7.2 11/04/2005 18:30:00 8.7 1.8 13.3 4.6 8.6 2 13.7 3.8 7.6 2 12.6 3.8 3 17 3 300 -7.1 0 -7 -7 11/04/2005 18:40:00 7.2 2.2 13.7 2.6 7.1 2.3 14.5 2.6 6.4 2.1 14.1 2.3 6 15 17 300 -7.1 0 -7 -7.2 11/04/2005 18:50:00 8.1 2.3 15.6 3.8 8 2.4 16.1 3.4 6.9 2.3 14.9 2.6 3 14 11 300 -7.1 0 -7 -7.2 11/04/2005 19:00:00 8.8 2.1 14.9 3.8 8.5 2.2 14.5 3.8 7.3 2.1 13.3 3 9 15 356 300 -7.1 0 -7 -7.2 11/04/2005 19:10:00 8.7 2.5 15.3 4.2 8.5 2.5 15.6 3.4 6.8 2.2 13.3 2.6 4 17 356 300 -7.1 0 -7 -7.2 11/04/2005 19:20:00 9 2.3 16.1 4.2 8.8 2.4 16.1 3.8 7.8 2.6 14.5 2.3 2 17 11 300 -7.3 0 -7.2 -7.4 11/04/2005 19:30:00 9.2 2.2 16.4 3.4 9.2 2.3 17.2 3.8 8 2.3 16.1 3.4 2 15 346 300 -7.3 0 -7.2 -7.4 11/04/2005 19:40:00 8.2 1.8 13 4.2 8 1.9 13.3 3.8 7 1.9 13.3 3.4 7 17 27 300 -7.3 0 -7.2 -7.2 11/04/2005 19:50:00 8.6 1.7 14.1 4.6 8.5 1.9 13.7 4.6 7.5 1.9 12.2 3 3 15 345 300 -7.4 0 -7.2 -7.4 11/04/2005 20:00:00 9.7 2 14.5 4.6 9.7 2.1 14.9 4.6 8.6 1.9 13 4.2 3 13 0 300 -7.3 0 -7.2 -7.4 11/04/2005 20:10:00 9.9 2.2 14.9 4.6 9.9 2.4 15.6 3.8 8.4 2.3 14.9 3 0 14 350 300 -7.3 0 -7.2 -7.4 11/04/2005 20:20:00 9.5 2.3 16.8 4.9 9.5 2.4 16.8 4.9 8.4 2.5 17.6 3.8 356 15 350 300 -7.4 0 -7.2 -7.6 11/04/2005 20:30:00 8.8 2.1 14.9 4.2 8.8 2.2 14.9 3.8 8 2.1 14.5 3.4 358 13 350 300 -7.5 0 -7.4 -7.6 11/04/2005 20:40:00 8 2.1 14.1 3.8 8 2.1 13.7 3.4 6.8 2 13 2.6 358 17 11 300 -7.5 0 -7.4 -7.6 11/04/2005 20:50:00 9.4 2.3 14.9 4.6 9.4 2.3 15.3 4.2 8.1 2.2 14.1 3.8 5 17 5 300 -7.5 0 -7.2 -7.6 11/04/2005 21:00:00 9.1 2.6 17.9 2.6 8.9 2.6 17.6 2.6 7.7 2.5 17.9 2.3 6 17 33 300 -7.5 0 -7.4 -7.6 11/04/2005 21:10:00 9.3 2.3 15.3 4.9 9.1 2.5 15.3 4.6 7.9 2.3 13.7 3 7 16 0 300 -7.6 0 -7.4 -7.6 11/04/2005 21:20:00 9.9 2.8 17.2 4.2 9.7 2.9 17.9 3.8 8.1 2.8 16.4 2.6 10 16 5 300 -7.6 0 -7.4 -7.6 11/04/2005 21:30:00 9.7 2.6 17.6 4.2 9.4 2.7 18.3 3.4 7.9 2.6 14.5 2.3 13 17 10 300 -7.6 0 -7.4 -7.6 11/04/2005 21:40:00 9 2.3 16.1 4.2 8.6 2.4 15.3 3.8 7.5 2.2 14.5 2.6 12 17 22 300 -7.5 0 -7.4 -7.6 11/04/2005 21:50:00 10.9 2.6 16.8 3.8 10.3 2.5 16.8 3 8.9 2.5 16.8 3.4 16 15 46 300 -7.5 0 -7.4 -7.6 11/04/2005 22:00:00 9.8 2.5 16.4 4.6 9.3 2.5 16.8 4.2 8.1 2.6 15.6 3.4 20 17 42 300 -7.5 0 -7.2 -7.6 11/04/2005 22:10:00 11.1 2.4 16.4 4.9 10.4 2.4 16.4 4.2 8.9 2.5 14.9 3.8 19 14 18 300 -7.4 0 -7.2 -7.6 11/04/2005 22:20:00 12.2 2.7 19.5 4.6 11.5 2.7 18.7 4.6 9.4 2.5 16.8 2.3 20 15 34 300 -7.5 0 -7.4 -7.6 11/04/2005 22:30:00 11.9 2.3 18.7 6.5 11.2 2.3 18.7 6.1 9.4 2.2 16.1 4.2 18 12 13 300 -7.6 0 -7.4 -7.6 11/04/2005 22:40:00 11.5 2.6 18.7 6.5 11.1 2.7 19.5 5.7 9.7 2.4 18.3 4.9 15 16 32 300 -7.6 0 -7.4 -7.6 11/04/2005 22:50:00 10.3 2.5 16.1 4.2 9.9 2.6 15.6 3.8 8.4 2.6 15.3 3.4 13 17 22 300 -7.6 0 -7.4 -7.6 11/04/2005 23:00:00 10.2 2.5 18.3 4.6 10.1 2.6 18.3 4.2 8.6 2.6 17.2 1.9 9 15 1 300 -7.7 0 -7.6 -7.9 11/04/2005 23:10:00 10.3 2.4 16.8 4.9 10 2.6 17.2 4.2 8.3 2.4 14.9 3 11 17 7 300 -7.9 0 -7.6 -8.1 11/04/2005 23:20:00 11 2.5 17.2 5.3 10.5 2.4 16.1 5.3 8.7 2.1 15.3 3.8 16 16 47 300 -7.8 0 -7.6 -8.1 11/04/2005 23:30:00 10.4 2.5 18.7 4.6 9.8 2.4 17.9 3.4 8.2 2 13.3 3.4 17 15 32 300 -7.7 0 -7.6 -7.9 11/04/2005 23:40:00 10.9 2.5 17.9 3.8 10.6 2.5 18.3 4.2 9 2.3 16.4 4.2 15 14 31 300 -7.9 0 -7.6 -8.1 11/04/2005 23:50:00 10.4 2.5 17.9 3.8 9.9 2.6 16.8 3.4 8.5 2.5 15.3 3 17 17 29 300 -8 0 -7.9 -8.1 11/05/2005 00:00:00 9.2 2.4 16.1 4.2 8.8 2.3 16.1 4.2 7.7 2 13.7 3.4 16 16 22 300 -8.1 0 -7.9 -8.3 11/05/2005 00:10:00 10.1 2.3 16.8 4.2 9.4 2.3 16.8 3.8 8 2.1 14.9 3.8 18 15 25 300 -8.1 0 -8.1 -8.1 11/05/2005 00:20:00 10.2 2.1 15.3 5.3 9.8 2.3 15.6 4.9 8.3 2.3 14.5 2.3 19 17 17 300 -8.1 0 -8.1 -8.1 11/05/2005 00:30:00 8.9 2.2 14.1 3.4 8.5 2.2 14.9 3 7.1 1.9 11.8 3 14 16 19 300 -8.2 0 -8.1 -8.3 11/05/2005 00:40:00 11 2.5 17.2 5.3 10.6 2.5 17.6 4.9 9.2 2.4 16.4 4.2 10 13 0 300 -8.2 0 -8.1 -8.3 11/05/2005 00:50:00 9.8 2.6 17.6 3.4 9.6 2.7 18.7 3.8 8.1 2.5 17.9 3.4 6 16 10 300 -8.3 0 -8.1 -8.5 11/05/2005 01:00:00 9.3 2.3 17.6 4.2 9.1 2.5 17.6 3.4 7.5 2.3 16.1 3.4 8 16 355 300 -8.3 0 -8.1 -8.5 11/05/2005 01:10:00 9.5 2.5 17.6 3.8 9.2 2.5 18.7 3.4 7.6 2.2 13.7 3 11 15 28 300 -8.4 0 -8.1 -8.5 11/05/2005 01:20:00 10.2 2.4 16.1 5.7 9.8 2.5 16.1 4.6 8.5 2.4 15.3 3.4 13 13 30 300 -8.4 0 -8.1 -8.5 11/05/2005 01:30:00 10.7 2.5 17.6 4.9 10.3 2.5 16.4 4.2 8.7 2.3 14.9 3 13 15 18 300 -8.5 0 -8.5 -8.7 11/05/2005 01:40:00 10.3 2.5 16.8 3.8 9.7 2.5 16.8 3.8 8 2.3 15.6 3.4 19 15 20 300 -8.6 0 -8.5 -8.7 11/05/2005 01:50:00 11 2.5 16.8 4.2 10.5 2.5 17.2 3.4 8.8 2.6 16.1 3 22 15 7 300 -8.5 0 -8.3 -8.7 11/05/2005 02:00:00 10.7 2.4 16.8 4.9 10 2.2 17.2 5.3 8.2 1.9 14.1 4.2 26 14 33 300 -8.3 0 -8.1 -8.5 11/05/2005 02:10:00 9.9 2 14.5 4.9 9.3 1.9 14.5 4.6 7.8 1.9 13.7 2.6 25 15 31 300 -8.4 0 -8.3 -8.5 11/05/2005 02:20:00 9.8 1.7 15.3 5.7 9.3 1.7 15.3 4.2 7.8 1.9 13.3 2.6 31 14 34 300 -8.4 0 -8.3 -8.5 11/05/2005 02:30:00 10 2 14.5 4.2 9.4 2 13.7 4.6 7.8 1.7 13 3 28 13 45 300 -8.5 0 -8.5 -8.7 11/05/2005 02:40:00 10 2.3 15.6 4.6 9.2 2.2 14.1 3.8 7.8 1.8 13.3 3 28 13 16 300 -8.5 0 -8.3 -8.7 11/05/2005 02:50:00 8.8 2.1 15.6 4.2 8.3 2.1 15.6 4.2 7.2 1.8 13.7 3 30 15 37 300 -8.6 0 -8.5 -8.7 11/05/2005 03:00:00 8.4 2.3 14.5 2.6 8 2.4 15.3 2.6 6.7 2 15.3 2.6 34 17 26 300 -8.7 0 -8.7 -8.9 11/05/2005 03:10:00 8.3 2.5 16.4 2.3 8 2.5 16.4 2.3 6.6 2 15.3 3 33 17 40 300 -8.7 0 -8.7 -8.9 11/05/2005 03:20:00 8.7 2.3 15.3 3.8 8.1 2.2 13 3.4 6.8 2.1 12.6 2.6 32 15 30 300 -8.9 0 -8.7 -8.9 11/05/2005 03:30:00 8.8 2.3 15.3 3.8 8.3 2.3 15.3 3.8 6.9 2 14.9 2.6 33 17 27 300 -8.9 0 -8.7 -8.9 11/05/2005 03:40:00 9.2 1.9 14.1 4.9 8.7 1.8 14.9 4.6 7.3 1.8 14.5 3 34 16 48 300 -9 0 -8.7 -9.1 11/05/2005 03:50:00 9 2.2 14.5 4.2 8.5 2.2 14.1 3 6.9 1.9 12.6 3 34 15 17 300 -9 0 -8.9 -9.1 11/05/2005 04:00:00 9.4 2 14.9 4.2 8.9 1.9 13.7 3.8 7.5 1.9 13.3 2.3 33 16 40 300 -8.9 0 -8.7 -8.9 11/05/2005 04:10:00 10 2.3 16.4 4.2 9.3 2.2 16.4 4.2 7.6 1.9 14.5 3.8 31 15 23 300 -9 0 -8.9 -9.1 11/05/2005 04:20:00 9.8 2.2 16.1 5.3 9.2 2.2 14.5 4.2 7.6 1.9 13 3.4 28 15 20 300 -9 0 -8.9 -9.1 11/05/2005 04:30:00 10.5 2.1 15.6 4.2 9.8 2.1 15.6 3 8.2 2.2 13.7 1.9 29 15 15 300 -8.9 0 -8.7 -8.9 11/05/2005 04:40:00 11.7 2.3 18.7 4.9 11 2.2 17.6 3.8 9 2.3 16.4 3.4 27 13 12 300 -9 0 -8.9 -9.1 11/05/2005 04:50:00 10.7 2.3 15.6 4.6 9.9 2.2 15.6 3.8 8.5 2.1 14.5 4.6 26 13 14 300 -9 0 -8.7 -8.9 11/05/2005 05:00:00 9.8 2.2 16.1 4.6 9.1 2.2 15.6 3.8 7.8 2.1 15.6 2.6 26 15 22 300 -9 0 -8.9 -9.1 11/05/2005 05:10:00 9.9 2 16.4 5.3 9.2 1.9 14.9 4.6 7.8 1.9 14.1 3 24 15 23 300 -9.1 0 -8.9 -9.1 11/05/2005 05:20:00 9.1 2.1 15.6 3.8 8.6 2.1 13.7 3.8 7.3 1.8 13.3 2.6 29 14 32 300 -9.1 0 -8.9 -9.3 11/05/2005 05:30:00 8.8 2.1 14.9 3.8 8.1 2.1 13.7 3.4 6.8 1.9 12.2 2.3 29 15 28 300 -9.2 0 -8.9 -9.3 11/05/2005 05:40:00 8.3 1.9 13.3 4.6 7.9 2 13.7 3.4 6.5 1.9 11.5 2.6 31 18 20 300 -9.2 0 -9.1 -9.3 11/05/2005 05:50:00 9.2 2 14.1 4.2 8.6 2 13 3.8 7.3 1.8 13 2.3 30 16 25 300 -9.3 0 -9.3 -9.3 11/05/2005 06:00:00 8.6 2 13.7 4.6 8.1 1.9 13.7 3.8 6.8 1.9 12.6 2.6 33 16 22 300 -9.3 0 -9.3 -9.3 11/05/2005 06:10:00 8 1.8 13.3 3.4 7.6 1.8 13 3.4 6.4 1.7 11.8 2.3 37 14 39 300 -9.4 0 -9.3 -9.5 11/05/2005 06:20:00 8.7 2 13 3.8 8.3 2 13.3 4.2 7 2 12.2 2.3 36 17 49 300 -9.4 0 -9.3 -9.5 11/05/2005 06:30:00 9.3 2.3 15.3 4.2 8.8 2.1 14.5 4.2 7.3 1.9 12.2 2.6 34 16 28 300 -9.3 0 -9.3 -9.3 11/05/2005 06:40:00 9.2 1.8 13.7 4.9 8.8 1.9 14.1 4.2 7.2 1.8 13.3 3.4 34 16 31 300 -9.3 0 -9.3 -9.3 11/05/2005 06:50:00 10.9 2.5 17.6 3.8 10.2 2.5 17.9 3 8.6 2.4 14.9 3 26 15 35 300 -9.2 0 -9.1 -9.3 11/05/2005 07:00:00 9.8 2.4 16.1 4.2 9.1 2.3 14.9 3.4 7.6 2.1 14.9 3.4 25 15 26 300 -9.1 0 -8.9 -9.3 11/05/2005 07:10:00 10.4 2.3 16.4 5.7 9.7 2.3 16.1 4.6 8.3 2 13.3 3 24 14 29 300 -9.1 0 -8.9 -9.1 11/05/2005 07:20:00 8.7 1.9 13.3 4.2 8.2 1.9 13 3.8 6.9 1.9 12.2 2.6 25 19 24 300 -9.1 0 -8.9 -9.1 11/05/2005 07:30:00 9.4 2.2 15.6 4.2 8.8 2.2 16.1 3.4 7.4 2 13.7 3 21 15 39 300 -9.1 0 -8.9 -9.1 11/05/2005 07:40:00 9.7 2.2 15.3 4.6 9.1 2.1 15.6 3.8 7.7 1.8 13.3 3 21 15 24 300 -9.1 0 -8.9 -9.1 11/05/2005 07:50:00 10.2 2.2 15.3 4.9 9.5 2.2 15.3 4.2 8.1 2.2 15.3 3 20 14 20 300 -9.1 0 -8.9 -9.1 11/05/2005 08:00:00 9.3 2.5 16.1 3.8 8.7 2.4 16.1 3.4 7.5 2 13.3 3 21 15 21 300 -9.1 0 -8.9 -9.3 11/05/2005 08:10:00 8.9 1.9 13.3 4.6 8.2 1.9 14.1 4.2 7.2 1.9 13.3 3.4 24 15 16 300 -9.1 0 -8.9 -9.1 11/05/2005 08:20:00 8.8 1.9 13.3 4.2 8.2 1.9 13.3 3.4 6.9 1.7 11.8 3 28 15 35 300 -9.1 0 -8.9 -9.3 11/05/2005 08:30:00 8.2 1.7 12.6 3.8 7.6 1.7 12.6 3 6.2 1.4 11.1 3 31 14 8 300 -9.1 0 -8.9 -9.3 11/05/2005 08:40:00 6.4 2 13 2.3 6.2 1.9 11.8 2.3 5.1 1.8 9.9 1.9 37 19 24 300 -9.1 0 -8.9 -9.3 11/05/2005 08:50:00 1.9 1.1 6.5 0.4 1.8 1.1 6.1 0.4 1.4 0.8 3.8 0.4 99 27 46 300 -10.5 0.8 -9.1 -11.4 11/05/2005 09:00:00 2.9 1 6.8 0.7 3 1 7.2 1.1 2.3 1.1 6.5 0.4 83 22 60 300 -11.6 0 -11.4 -11.8 11/05/2005 09:10:00 2.6 0.7 4.2 0.7 2.6 0.7 4.2 0.7 2.1 0.6 3 0.7 61 11 57 300 -11.5 0 -11.4 -11.6 11/05/2005 09:20:00 2.7 0.4 3.4 1.5 2.7 0.4 3.4 1.5 1.9 0.5 3 0.7 47 4 41 300 -11.6 0.1 -11.4 -11.8 11/05/2005 09:30:00 2.5 0.5 3.8 1.1 2.5 0.5 3.8 1.1 1.9 0.5 3 0.4 51 7 48 300 -11.7 0 -11.4 -11.8 11/05/2005 09:40:00 1.9 0.5 3 0.7 1.9 0.5 3 0.4 1.5 0.4 2.3 0.7 50 7 49 300 -11.3 0.2 -11 -11.6 11/05/2005 09:50:00 1 0.4 1.9 0.4 1 0.4 1.9 0.4 0.6 0.3 1.5 0.4 59 9 59 300 -10.7 0.1 -10.4 -11 11/05/2005 10:00:00 1.3 0.5 2.6 0.4 1.2 0.5 2.6 0.4 1.4 0.4 2.6 0.4 113 45 62 300 -10.4 0.1 -10.2 -10.6 11/05/2005 10:10:00 1.6 0.6 3 0.7 1.5 0.6 3 0.4 1.6 0.5 2.6 0.7 182 6 180 300 -10.6 0 -10.2 -10.8 11/05/2005 10:20:00 1 0.5 1.9 0.4 0.9 0.5 1.9 0.4 0.9 0.5 1.9 0.4 143 24 171 300 -10 0.2 -9.5 -10.4 11/05/2005 10:30:00 1.8 0.5 3 0.7 1.7 0.5 3 0.4 1.3 0.5 3 0.4 76 19 78 300 -9.1 0.2 -8.7 -9.5 11/05/2005 10:40:00 1 0.6 2.3 0.4 0.9 0.6 2.3 0.4 0.7 0.5 1.9 0.4 57 22 31 300 -8.3 0 -8.1 -8.7 11/05/2005 10:50:00 1 0.6 2.6 0.4 1 0.6 2.6 0.4 1 0.5 2.6 0.4 57 11 67 300 -8 0.1 -7.6 -8.3 11/05/2005 11:00:00 0.7 0.4 1.9 0.4 0.7 0.4 1.9 0.4 0.8 0.4 1.9 0.4 64 13 61 300 -7.5 0 -7.2 -7.6 11/05/2005 11:10:00 1 0.5 1.9 0.4 0.9 0.5 1.9 0.4 1 0.5 2.3 0.4 54 12 51 300 -7.5 0 -7.2 -7.6 11/05/2005 11:20:00 1 0.5 2.3 0.4 0.9 0.5 2.3 0.4 0.8 0.4 1.9 0.4 47 27 27 300 -6.9 0.3 -6.1 -7.4 11/05/2005 11:30:00 1.8 0.6 3.4 0.7 1.7 0.6 3.4 0.4 1.7 0.5 3 0.4 70 20 49 300 -6.5 0.2 -6.1 -7 11/05/2005 11:40:00 1.5 0.6 3 0.4 1.4 0.5 2.6 0.4 1.3 0.5 2.3 0.4 45 23 72 300 -6.8 0 -6.6 -7 11/05/2005 11:50:00 3.3 1 5.7 1.1 3.2 1 5.7 0.7 2.8 1 4.9 0.7 39 13 26 300 -7.2 0.2 -6.8 -7.4 11/05/2005 12:00:00 3.4 0.8 4.9 0.4 3.2 0.8 4.9 0.4 2.4 0.7 4.2 0.7 28 12 38 300 -7.3 0.1 -7 -7.6 11/05/2005 12:10:00 2.8 0.8 4.6 0.7 2.7 0.9 4.9 0.4 2.3 0.8 4.2 0.4 31 20 62 300 -7 0 -6.6 -7 11/05/2005 12:20:00 4.4 1.8 10.3 0.7 4.2 1.7 9.5 1.1 3.5 1.5 8.8 1.1 34 22 23 300 -6.5 0 -6.1 -6.8 11/05/2005 12:30:00 6 1.7 11.1 1.1 5.7 1.7 10.7 1.1 4.8 1.5 9.5 1.1 22 17 17 300 -6.2 0 -5.9 -6.4 11/05/2005 12:40:00 5.5 1 8.4 3 5.3 1 8.4 2.6 4.2 1.1 7.6 1.9 40 17 32 300 -5.9 0 -5.7 -5.9 11/05/2005 12:50:00 5.5 1.5 10.3 1.9 5.3 1.4 9.1 1.5 4.2 1.3 9.1 1.5 44 22 26 300 -5.8 0 -5.5 -5.9 11/05/2005 13:00:00 6.1 2.8 13.3 1.9 5.8 2.8 14.1 1.5 4.6 2.4 12.2 0.7 31 21 43 300 -5.7 0 -5.5 -5.9 11/05/2005 13:10:00 6.9 2.1 13 3 6.7 2.1 13 3 5.7 1.8 11.1 1.9 36 18 35 300 -5.8 0.1 -5.5 -5.9 11/05/2005 13:20:00 6.8 1.7 11.8 2.6 6.6 1.7 10.7 2.3 5.3 1.7 9.1 1.1 44 17 20 300 -5.6 0 -5.5 -5.7 11/05/2005 13:30:00 6 2.1 13.3 0.7 5.8 2.1 13.3 0.4 4.9 1.8 11.5 1.1 46 24 54 300 -5.2 0 -4.8 -5.5 11/05/2005 13:40:00 8 1.8 13.3 3.8 7.6 1.8 13 3.4 6.3 1.7 12.2 3 32 17 35 300 -5 0 -4.8 -5.3 11/05/2005 13:50:00 8.6 2 14.5 3.8 8.3 2.1 14.5 4.2 6.9 2 12.6 2.3 26 18 16 300 -5 0 -4.8 -5 11/05/2005 14:00:00 8 2.3 13.3 3.4 7.5 2.3 14.1 3 6.5 2 11.8 2.6 18 16 12 300 -4.8 0 -4.6 -4.8 11/05/2005 14:10:00 8.8 2.4 15.6 3.4 8.4 2.3 16.4 3.4 7.3 1.8 13 3 20 17 30 300 -4.9 0 -4.6 -4.8 11/05/2005 14:20:00 8.1 2.3 15.6 3.8 7.7 2.3 14.1 3 6.3 1.7 11.5 2.6 23 18 10 300 -4.8 0 -4.6 -4.8 11/05/2005 14:30:00 8.1 2.2 13.3 3.4 7.7 2.2 13.3 3.4 6.7 2.1 13 3 20 17 16 300 -4.8 0 -4.6 -4.8 11/05/2005 14:40:00 8.6 2.3 15.3 3.4 8.2 2.3 16.1 3 6.9 2.1 13.3 2.6 20 17 15 300 -4.9 0 -4.8 -5 11/05/2005 14:50:00 8.3 2.8 15.3 1.9 7.9 2.9 16.1 1.9 6.8 2.6 14.9 2.3 17 17 17 300 -4.9 0 -4.6 -5 11/05/2005 15:00:00 8.7 1.9 16.1 4.2 8.2 2 16.4 3.4 6.7 1.7 12.6 2.6 19 17 31 300 -5 0 -5 -5 11/05/2005 15:10:00 9 2 13.7 3.8 8.4 1.9 13.3 4.2 7.2 1.8 12.2 3 16 14 356 300 -5.1 0 -5 -5.3 11/05/2005 15:20:00 8.8 2 13.7 4.2 8.4 2.1 14.1 3.8 7.1 2 14.1 2.3 19 15 6 300 -5.1 0 -5 -5.3 11/05/2005 15:30:00 8.7 2.3 15.3 3.8 8.3 2.3 13.7 3 7 2.4 13.3 1.5 16 15 25 300 -5 0 -4.8 -5 11/05/2005 15:40:00 7.7 2.3 14.9 3 7.5 2.3 13.7 3 6.2 2.1 12.2 2.6 16 17 28 300 -5 0 -5 -5 11/05/2005 15:50:00 7.1 1.7 11.5 3 6.7 1.8 12.2 3 5.6 1.6 10.7 2.6 15 19 19 300 -5.2 0 -5 -5.5 11/05/2005 16:00:00 7.2 1.9 13 1.5 7 2 12.2 1.9 6.1 1.7 11.1 2.3 11 19 12 300 -5.4 0 -5.3 -5.5 11/05/2005 16:10:00 7.4 2.6 14.1 3 7.2 2.7 14.5 2.3 6.2 2.5 13.3 1.9 8 17 18 300 -5.4 0 -5.5 -5.5 11/05/2005 16:20:00 7.5 2.2 13.7 3 7.4 2.3 14.1 2.3 6.2 2 11.8 2.6 3 17 356 300 -5.6 0 -5.5 -5.7 11/05/2005 16:30:00 7.5 1.9 14.1 3 7.4 1.9 14.5 3 6.4 2.1 13.7 2.6 2 17 347 300 -5.8 0 -5.7 -5.9 11/05/2005 16:40:00 6.1 1.7 9.9 1.5 5.9 1.7 9.9 1.5 5 1.5 9.1 1.9 11 17 28 300 -6 0 -5.9 -6.1 11/05/2005 16:50:00 7.1 1.7 12.2 3 7 1.8 12.6 3 5.9 1.6 11.1 2.3 7 19 6 300 -6.1 0 -5.9 -6.1 11/05/2005 17:00:00 7.3 2.1 14.1 3 7 2.2 14.1 2.6 6 1.9 12.2 2.3 11 17 10 300 -6.2 0 -6.1 -6.4 11/05/2005 17:10:00 9.2 2.2 16.4 4.2 9 2.3 17.2 4.2 7.7 2.5 14.9 3.4 11 16 1 300 -6.2 0 -5.9 -6.4 11/05/2005 17:20:00 8.4 2.6 17.9 3.8 8.4 2.7 18.7 3.4 7.5 2.5 14.9 1.9 6 17 355 300 -6.2 0 -6.1 -6.4 11/05/2005 17:30:00 7.9 2.4 14.5 3.4 7.8 2.5 15.3 3.8 6.8 2.1 16.4 3.4 4 16 24 300 -6.1 0 -5.9 -6.1 11/05/2005 17:40:00 9.2 2.8 17.2 4.2 9.2 2.9 17.9 4.2 8.1 2.7 17.6 2.6 2 14 359 300 -6.1 0 -5.9 -6.1 11/05/2005 17:50:00 11.3 3.1 20.2 3.8 11.2 3.2 21.4 4.2 9.5 2.8 18.3 3.4 8 15 12 300 -6.1 0 -5.9 -6.1 11/05/2005 18:00:00 10.9 2.7 17.9 4.6 10.6 2.8 18.7 3.8 9.1 2.7 17.6 4.6 14 17 16 300 -6.1 0 -5.9 -6.4 11/05/2005 18:10:00 8.9 2.5 14.9 3.8 8.7 2.5 15.3 3.8 7.3 2.5 14.5 2.6 11 17 346 300 -6.3 0 -6.1 -6.6 11/05/2005 18:20:00 9.6 2.7 16.8 4.2 9.3 2.8 17.2 3.8 7.9 2.7 15.6 2.6 13 17 5 300 -6.5 0 -6.4 -6.6 11/05/2005 18:30:00 9 1.9 14.9 4.2 8.4 1.8 14.5 3.8 7.2 1.7 11.8 2.6 17 15 14 300 -6.5 0 -6.4 -6.6 11/05/2005 18:40:00 8.7 2.4 15.3 3 8.3 2.5 16.1 2.6 7.1 2.1 14.5 3 15 16 13 300 -6.7 0 -6.6 -6.8 11/05/2005 18:50:00 8 2.4 13.3 2.6 7.7 2.5 14.1 2.6 6.7 2.2 12.2 1.9 11 17 9 300 -6.7 0 -6.6 -6.8 11/05/2005 19:00:00 7.2 1.6 11.1 3.4 7 1.7 11.1 3 6 1.7 10.3 2.6 9 17 2 300 -6.9 0 -6.8 -7 11/05/2005 19:10:00 6.8 1.6 10.7 3.4 6.7 1.7 11.8 3.4 5.7 1.7 11.1 2.3 10 17 50 300 -7 0 -6.8 -7 11/05/2005 19:20:00 7.7 1.7 12.2 2.3 7.3 1.7 12.6 1.9 6.2 1.6 12.2 2.6 15 16 6 300 -7.1 0 -6.8 -7 11/05/2005 19:30:00 8.7 2.3 13.7 3.4 8.2 2.3 14.5 3 7 2.1 13.3 2.6 17 17 30 300 -6.9 0 -6.6 -7 11/05/2005 19:40:00 6.9 1.9 11.1 3 6.6 1.8 10.7 2.3 5.7 1.8 11.1 0.7 14 19 24 300 -6.9 0.1 -6.6 -7 11/05/2005 19:50:00 6.7 1.8 12.6 2.6 6.5 1.9 13.3 2.3 5.5 1.5 9.9 1.9 10 16 9 300 -7.1 0 -7 -7 11/05/2005 20:00:00 7.1 1.7 11.5 1.9 6.9 1.7 11.5 1.9 5.7 1.5 9.9 2.6 7 15 342 300 -7.1 0 -7 -7.2 11/05/2005 20:10:00 7 1.9 12.6 3 6.8 1.9 12.6 2.6 6 1.9 11.5 1.1 6 17 350 300 -7.3 0 -7 -7.4 11/05/2005 20:20:00 8.7 2 13.7 4.2 8.4 2 14.9 3.8 7.1 1.9 11.1 3 12 17 10 300 -7.1 0 -7 -7.4 11/05/2005 20:30:00 8.2 1.7 13 4.2 8.2 1.9 13.3 4.2 6.9 2.1 14.1 2.6 4 15 7 300 -7.4 0 -7.2 -7.4 11/05/2005 20:40:00 8.8 1.7 12.6 4.6 8.7 1.8 12.6 3.8 7.3 2 12.6 3 7 15 20 300 -7.4 0 -7.2 -7.4 11/05/2005 20:50:00 7.3 1.5 11.8 3.4 7.3 1.7 11.8 3 6.1 1.6 10.7 1.9 3 15 7 300 -7.4 0 -7.2 -7.6 11/05/2005 21:00:00 7.1 1.3 11.1 3.8 6.8 1.3 11.1 3.4 5.8 1.3 9.1 1.9 12 17 23 300 -7.6 0 -7.6 -7.6 11/05/2005 21:10:00 8 1.6 11.5 4.2 7.6 1.7 11.8 3.8 6.6 1.7 11.1 2.6 16 15 25 300 -7.9 0 -7.6 -7.9 11/05/2005 21:20:00 7.4 1.5 10.3 3 6.9 1.5 10.7 3 5.9 1.2 8.8 3 18 13 17 300 -7.9 0 -7.6 -8.1 11/05/2005 21:30:00 6.5 1.8 10.7 2.3 6.3 1.7 10.7 1.5 5.3 1.5 9.1 1.9 12 14 14 300 -8 0 -7.9 -8.1 11/05/2005 21:40:00 6.8 1.5 11.8 3 6.6 1.7 12.2 3 5.4 1.5 11.1 1.9 12 14 12 300 -8.1 0 -8.1 -8.1 11/05/2005 21:50:00 6.6 1.5 11.1 2.6 6.4 1.5 11.8 2.3 5.4 1.4 10.3 2.6 13 14 19 300 -8.1 0 -8.1 -8.1 11/05/2005 22:00:00 7 1.5 10.7 3.8 6.6 1.5 10.3 3 5.5 1.5 9.9 1.9 14 15 26 300 -8.2 0 -8.1 -8.3 11/05/2005 22:10:00 6.5 1.8 11.1 2.6 6.4 2 11.5 2.6 5.2 1.8 11.1 1.5 10 15 359 300 -8.4 0 -8.1 -8.7 11/05/2005 22:20:00 6.3 1.6 9.9 2.6 6.2 1.7 10.7 2.6 5.3 1.5 10.3 1.5 12 13 21 300 -8.7 0 -8.5 -8.7 11/05/2005 22:30:00 5.7 1.6 10.3 1.9 5.6 1.6 10.7 1.9 4.7 1.2 8.4 1.9 9 16 28 300 -8.8 0 -8.5 -8.9 11/05/2005 22:40:00 5.4 1.5 9.9 2.6 5.3 1.7 9.9 1.9 4.5 1.4 8.8 1.5 9 18 350 300 -8.8 0 -8.7 -8.9 11/05/2005 22:50:00 5.8 1.7 10.3 2.3 5.6 1.9 10.7 1.9 4.7 1.5 9.1 1.9 14 15 22 300 -9 0 -8.7 -8.9 11/05/2005 23:00:00 5.9 1.2 9.5 3 5.5 1.2 8.4 2.6 4.7 1.1 7.6 1.1 17 12 28 300 -9 0 -8.9 -9.1 11/05/2005 23:10:00 6.1 1.2 9.9 3 5.6 1.2 9.1 2.3 4.6 1.1 8 2.3 26 14 24 300 -9.1 0 -8.9 -9.3 11/05/2005 23:20:00 6.2 1.3 8.8 2.6 5.7 1.2 8.8 2.6 4.7 1.1 8 2.3 28 13 22 300 -9.2 0 -9.1 -9.3 11/05/2005 23:30:00 6.2 1.3 10.7 3 5.7 1.2 9.5 3 4.8 1 8 3 28 12 36 300 -9.3 0 -9.1 -9.3 11/05/2005 23:40:00 5.6 1.1 8.8 3 5.1 1.1 8.8 3 4.3 1.2 9.1 1.9 25 13 32 300 -9.4 0 -9.3 -9.5 11/05/2005 23:50:00 4.7 1.1 7.6 2.3 4.4 1.1 8 1.9 3.7 1 6.8 1.1 26 14 11 300 -9.5 0 -9.3 -9.7 11/06/2005 00:00:00 5.4 1 8.4 3 5 1 8 3 4.2 0.9 8 2.3 30 11 27 300 -9.6 0.1 -9.3 -10.2 11/06/2005 00:10:00 6.2 1 9.1 3 5.8 1.1 9.1 2.6 4.8 1 8 2.3 32 12 42 300 -9.7 0 -9.7 -9.7 11/06/2005 00:20:00 6.3 1.3 9.5 2.6 6.1 1.5 9.9 2.3 4.9 1.3 8 1.5 37 12 38 300 -9.8 0 -9.7 -10 11/06/2005 00:30:00 6.5 1.1 8.8 3.8 6.4 1.2 9.1 3.4 5.1 1.2 8.4 2.6 39 9 39 300 -10 0 -9.7 -10.2 11/06/2005 00:40:00 5.6 1.1 8 2.6 5.6 1.2 8.4 1.9 4.3 1.2 7.2 0.7 45 11 41 300 -10.2 0 -10 -10.4 11/06/2005 00:50:00 4.9 1 7.2 2.3 4.9 1 7.2 2.3 3.8 0.9 6.5 1.5 50 11 53 300 -10.3 0 -10.2 -10.4 11/06/2005 01:00:00 4.2 1 6.8 0.7 4.3 1 6.8 1.1 3.1 1 5.7 0.7 51 12 54 300 -10.3 0 -10.2 -11 11/06/2005 01:10:00 2.5 0.8 4.2 0.4 2.6 0.8 4.6 0.4 1.8 0.6 3 0.4 46 12 30 300 -10.6 0 -10.4 -11 11/06/2005 01:20:00 0.8 0.5 2.6 0.4 0.9 0.5 2.3 0.4 0.8 0.4 1.9 0.4 75 41 7 300 -10.8 0.1 -10.6 -11 11/06/2005 01:30:00 1.2 0.3 1.9 0.4 1.3 0.3 1.9 0.7 1.3 0.2 1.9 0.7 133 21 149 300 -11.7 0.3 -11 -12.2 11/06/2005 01:40:00 1 0.4 1.9 0.4 1.1 0.3 1.9 0.4 1.1 0.3 1.9 0.4 86 15 107 300 -12.5 0.1 -12.2 -12.6 11/06/2005 01:50:00 1.4 0.3 2.3 0.7 1.5 0.3 2.3 0.7 1.2 0.3 1.9 0.4 59 6 41 300 -12.4 0.1 -12 -12.6 11/06/2005 02:00:00 1.9 0.3 2.6 1.1 1.9 0.4 2.6 0.7 1.3 0.3 2.3 0.4 37 6 49 300 -12.2 0.1 -12 -12.4 11/06/2005 02:10:00 3.4 0.6 4.9 1.1 3.2 0.6 4.6 1.5 2.3 0.5 3.4 1.1 37 8 38 300 -12.7 0.1 -12.4 -13 11/06/2005 02:20:00 3.1 0.8 4.9 1.1 3 0.8 4.9 1.1 2.2 0.7 4.6 0.4 45 14 48 300 -12.7 0 -12.6 -12.8 11/06/2005 02:30:00 3.3 0.7 4.9 1.1 3.4 0.7 5.3 1.1 2.4 0.6 4.6 0.7 57 9 56 300 -12.6 0 -12.6 -12.8 11/06/2005 02:40:00 3.8 0.8 5.3 1.9 3.9 0.8 5.7 1.9 3.1 0.7 5.3 1.1 59 11 51 300 -12.4 0 -12.2 -12.6 11/06/2005 02:50:00 4 0.8 6.5 1.9 4 0.8 6.5 1.9 3.1 0.9 5.3 0.7 54 12 57 300 -12 0 -11.8 -12.2 11/06/2005 03:00:00 3.2 0.7 4.6 1.1 3.2 0.7 4.9 1.1 2.1 0.7 3.8 0.4 51 12 47 300 -11.8 0 -11.6 -11.8 11/06/2005 03:10:00 3.6 0.6 5.3 1.5 3.5 0.6 5.3 1.9 2.7 0.7 4.2 1.1 43 9 40 300 -11.6 0 -11.4 -11.8 11/06/2005 03:20:00 3.1 0.6 4.6 1.5 3 0.6 4.6 1.5 2.1 0.7 3.8 0.7 36 11 37 300 -11.5 0 -11.4 -11.6 11/06/2005 03:30:00 2.9 0.5 4.2 1.9 2.9 0.5 4.2 1.5 2.1 0.6 3.4 0.4 38 8 44 300 -11.5 0 -11.4 -11.4 11/06/2005 03:40:00 3.3 0.6 4.6 1.9 3.2 0.7 4.6 1.5 2.3 0.6 4.2 0.7 38 9 35 300 -11.4 0 -11.2 -11.4 11/06/2005 03:50:00 3.1 0.6 4.6 1.9 3 0.6 4.6 1.5 2 0.8 3.8 0.4 41 12 35 300 -11.2 0 -11 -11.4 11/06/2005 04:00:00 3.8 0.8 5.3 1.9 3.6 0.8 5.3 1.9 2.6 0.7 4.9 1.1 37 11 35 300 -11 0 -11 -11.4 11/06/2005 04:10:00 4.4 0.8 6.5 2.3 4.3 0.9 6.8 1.5 3.2 0.8 5.7 1.5 40 11 46 300 -10.9 0 -11 -11 11/06/2005 04:20:00 3.6 0.7 4.9 1.5 3.4 0.7 5.3 1.5 2.6 0.7 4.6 0.7 41 14 52 300 -10.9 0 -11 -11 11/06/2005 04:30:00 3.7 0.6 4.9 1.5 3.2 0.6 4.9 1.1 2.5 0.6 4.6 1.1 27 8 37 300 -10.9 0 -10.8 -11 11/06/2005 04:40:00 3.7 0.5 4.9 2.3 3.5 0.5 4.9 1.9 2.8 0.6 4.2 1.1 34 8 33 300 -10.8 0 -10.6 -11 11/06/2005 04:50:00 3.9 0.8 5.7 1.5 3.8 0.8 5.3 1.5 3 0.7 5.3 1.1 39 10 44 300 -10.7 0 -10.6 -10.8 11/06/2005 05:00:00 3.8 0.8 5.3 1.5 3.8 0.8 5.3 1.1 2.6 0.8 4.9 0.7 43 11 27 300 -10.6 0 -10.6 -10.8 11/06/2005 05:10:00 3.3 0.7 4.9 1.1 3.1 0.7 4.9 1.5 2.2 0.6 3.8 0.7 39 11 66 300 -10.5 0 -10.4 -10.6 11/06/2005 05:20:00 3.9 0.6 5.3 2.3 3.5 0.6 4.9 1.9 2.9 0.6 4.6 0.7 26 9 14 300 -10.5 0 -10.4 -10.6 11/06/2005 05:30:00 3.9 0.7 5.3 1.9 3.5 0.7 5.3 1.5 2.8 0.6 4.6 1.1 24 9 31 300 -10.4 0 -10.4 -10.6 11/06/2005 05:40:00 4 0.7 5.7 2.3 3.6 0.7 5.7 1.5 2.9 0.6 4.6 1.5 26 10 31 300 -10.4 0 -10.2 -10.4 11/06/2005 05:50:00 4.2 0.7 6.1 2.6 3.8 0.8 6.1 1.9 3.2 0.6 5.3 1.5 22 9 22 300 -10.3 0 -10.2 -10.4 11/06/2005 06:00:00 3.7 0.7 5.3 1.9 3.4 0.7 5.3 1.5 2.8 0.7 4.6 0.7 17 11 26 300 -10.1 0 -10.2 -10.4 11/06/2005 06:10:00 2.9 0.6 4.6 1.5 2.8 0.7 4.9 1.1 2.2 0.7 4.2 0.7 17 12 1 300 -10.1 0 -10 -10.2 11/06/2005 06:20:00 3.4 0.6 4.9 1.9 3.1 0.6 4.6 1.5 2.5 0.5 4.2 0.7 27 10 26 300 -10.1 0 -10 -10.2 11/06/2005 06:30:00 2.9 0.6 4.6 1.5 2.7 0.6 4.2 1.1 2.4 0.6 3.8 1.1 33 10 28 300 -10.1 0 -10 -10.2 11/06/2005 06:40:00 3 0.4 4.2 1.9 2.8 0.5 3.8 1.5 2.2 0.6 3.8 0.7 29 10 26 300 -10 0 -10 -10.2 11/06/2005 06:50:00 1.5 0.8 3.4 0.4 1.4 0.8 3.4 0.4 1.2 0.6 3 0.4 19 20 24 300 -10 0 -9.7 -10.2 11/06/2005 07:00:00 1.9 0.5 3 0.7 2 0.5 3.4 0.7 1.7 0.5 3 0.4 359 8 6 300 -9.8 0 -9.7 -10 11/06/2005 07:10:00 2.5 0.4 3.8 1.5 2.5 0.5 3.8 0.7 2.1 0.6 3.4 0.7 6 10 2 300 -9.8 0 -9.7 -10 11/06/2005 07:20:00 2.9 0.6 4.2 1.5 2.8 0.7 4.6 1.1 2.2 0.7 3.8 0.7 16 9 6 300 -9.8 0 -9.7 -10 11/06/2005 07:30:00 2.9 0.7 4.6 1.1 2.7 0.7 4.2 0.7 2.3 0.6 3.8 1.1 35 14 39 300 -9.7 0 -9.7 -9.7 11/06/2005 07:40:00 2.7 0.8 4.6 0.4 2.7 0.8 4.9 0.7 2.2 0.9 4.9 0.7 39 13 41 300 -9.7 0 -9.7 -9.7 11/06/2005 07:50:00 2.4 0.7 4.6 0.7 2.3 0.7 4.6 0.7 1.8 0.6 3.8 0.4 44 14 54 300 -9.9 0 -9.7 -10.2 11/06/2005 08:00:00 3.3 0.7 4.9 0.4 3.1 0.7 4.9 1.1 2.5 0.8 4.6 0.4 38 11 52 300 -10.3 0 -10.2 -10.6 11/06/2005 08:10:00 4.1 0.6 5.3 2.3 4.1 0.6 5.7 2.3 3 0.7 4.6 1.5 47 8 50 300 -10.4 0 -10.4 -10.6 11/06/2005 08:20:00 3.5 0.7 5.3 1.9 3.5 0.7 5.3 1.9 2.8 0.8 4.9 0.7 45 9 41 300 -10.4 0 -10.2 -10.6 11/06/2005 08:30:00 3.6 0.7 5.3 1.5 3.4 0.7 4.9 1.1 2.9 0.7 4.9 1.5 36 12 22 300 -10.1 0.1 -9.7 -10.4 11/06/2005 08:40:00 5.4 1.2 8.4 2.3 4.9 1.1 7.6 2.3 4.1 0.9 6.5 1.9 32 13 62 300 -9.7 0 -9.7 -10 11/06/2005 08:50:00 5.7 1 8 2.3 5.3 1.1 8.8 1.9 4.5 1 7.2 2.3 35 12 28 300 -10.3 0.1 -9.7 -10.6 11/06/2005 09:00:00 6.1 1.2 9.5 3 6 1.3 9.5 3 4.9 1.2 8 1.9 41 11 33 300 -10.4 0 -10.2 -10.6 11/06/2005 09:10:00 6.7 1.2 9.9 3.8 6.6 1.3 9.5 3 5.2 1.2 8.4 2.3 39 11 35 300 -10.3 0 -10.2 -10.4 11/06/2005 09:20:00 5.9 1.1 9.1 3 5.7 1.2 9.5 3 4.6 1 7.2 2.3 39 13 48 300 -10.2 0 -10.2 -10.4 11/06/2005 09:30:00 5.3 0.9 8 3 5.1 0.9 7.2 2.6 4 1 7.2 1.5 41 13 32 300 -10.1 0 -10 -10.2 11/06/2005 09:40:00 5.1 1.1 7.6 1.9 5 1.1 7.6 1.9 3.9 1.2 6.5 1.1 39 12 40 300 -10 0 -9.7 -10.2 11/06/2005 09:50:00 4.9 1 6.8 1.9 4.7 1 6.8 1.9 3.6 1.1 6.8 0.7 37 13 32 300 -9.8 0 -9.7 -10.2 11/06/2005 10:00:00 4.1 0.9 6.5 1.1 3.9 0.9 5.7 1.1 3.3 0.9 5.7 1.5 39 12 21 300 -9.7 0 -9.5 -9.7 11/06/2005 10:10:00 4.1 0.7 6.1 2.3 3.8 0.8 6.1 1.9 3.1 0.8 4.9 1.1 38 12 17 300 -9.7 0 -9.5 -9.7 11/06/2005 10:20:00 4.3 0.7 5.7 2.6 3.8 0.7 5.7 2.3 3.1 0.7 4.9 0.7 29 10 24 300 -9.7 0 -9.7 -9.7 11/06/2005 10:30:00 3.7 0.8 5.3 1.1 3.5 0.8 5.3 1.1 2.6 0.8 4.9 0.7 38 13 17 300 -9.6 0 -9.5 -9.7 11/06/2005 10:40:00 3.9 1 5.7 1.5 3.7 1 6.1 1.1 3 1 5.7 0.7 36 11 24 300 -9.5 0 -9.3 -9.5 11/06/2005 10:50:00 4.3 0.7 5.7 1.9 3.8 0.7 5.3 1.9 3.2 0.7 4.9 1.5 28 9 29 300 -9.4 0 -9.3 -9.5 11/06/2005 11:00:00 3.8 0.8 5.7 1.5 3.4 0.8 5.7 1.1 2.9 0.8 4.9 1.1 27 11 20 300 -9.3 0 -9.3 -9.7 11/06/2005 11:10:00 4.5 0.7 6.5 1.9 4 0.8 6.1 1.5 3.3 0.8 5.7 1.5 23 11 15 300 -9.1 0.1 -8.9 -9.3 11/06/2005 11:20:00 4.3 1 6.1 1.1 4 1 6.1 1.1 3.4 1 6.1 1.1 16 12 359 300 -9.1 0 -8.9 -9.1 11/06/2005 11:30:00 3.9 0.8 5.7 1.9 3.6 0.9 6.1 1.5 3 0.8 5.3 1.1 16 12 32 300 -9.1 0 -8.9 -9.3 11/06/2005 11:40:00 3.6 0.7 5.3 1.5 3.4 0.8 5.3 1.1 3 0.6 5.3 1.5 16 11 17 300 -9.2 0 -9.1 -9.3 11/06/2005 11:50:00 3 0.8 4.6 0.7 2.7 0.9 4.6 0.7 2.2 0.8 4.2 0.4 16 12 2 300 -9.3 0 -9.1 -9.3 11/06/2005 12:00:00 2.4 0.6 3.8 0.7 2.3 0.6 3.8 0.7 2.1 0.6 3.4 0.4 7 12 18 300 -9.3 0 -9.3 -9.3 11/06/2005 12:10:00 2.1 0.7 3.8 0.4 2.1 0.8 3.8 0.4 1.9 0.6 3.8 0.7 4 11 13 300 -9.2 0 -9.1 -9.3 11/06/2005 12:20:00 2.4 0.6 3.8 0.7 2.4 0.7 3.8 0.7 2 0.7 3.8 0.4 5 13 350 300 -8.7 0.3 -8.1 -9.1 11/06/2005 12:30:00 2.1 0.6 3.4 0.4 2 0.6 3.8 0.4 1.7 0.6 3.4 0.4 12 17 39 300 -7.8 0.1 -7.4 -8.1 11/06/2005 12:40:00 1.6 0.7 3.4 0.4 1.4 0.7 3.4 0.4 1.5 0.6 3 0.4 22 22 43 300 -7.4 0.2 -7 -7.6 11/06/2005 12:50:00 2.3 0.6 3.8 1.1 2.1 0.6 3.8 0.7 2 0.6 3 0.4 15 13 31 300 -7.3 0.1 -7 -7.4 11/06/2005 13:00:00 1.3 0.6 2.6 0.4 1.2 0.6 2.6 0.4 1.4 0.4 2.6 0.4 1 19 24 300 -7.1 0 -6.8 -7.6 11/06/2005 13:10:00 2 1 3.8 0.4 2 1 3.8 0.4 2.1 0.9 3.8 0.4 0 15 352 300 -7 0 -6.8 -7 11/06/2005 13:20:00 2.8 1.2 4.9 0.4 2.8 1.3 5.3 0.4 2.4 1.1 5.3 0.4 11 20 30 300 -7 0 -6.8 -7.2 11/06/2005 13:30:00 2.9 1.3 6.1 0.4 2.8 1.3 6.5 0.4 2.8 1 6.5 0.7 10 18 1 300 -7.1 0 -6.8 -7.2 11/06/2005 13:40:00 3.8 0.9 6.5 1.9 3.7 0.9 6.8 1.9 3.2 0.8 6.1 1.5 14 16 20 300 -7.2 0 -7 -7.4 11/06/2005 13:50:00 4.4 0.9 6.8 2.3 4.1 1 6.5 1.5 3.6 1 6.5 1.5 21 13 36 300 -7.3 0 -7.2 -7.4 11/06/2005 14:00:00 5.4 1.3 8.8 1.9 5.1 1.4 9.1 1.9 4.3 1.4 8.8 1.1 23 18 3 300 -7.4 0 -7.2 -7.4 11/06/2005 14:10:00 6.8 1.5 10.3 3 6.4 1.5 10.3 2.6 5.4 1.3 8.8 2.3 31 14 44 300 -7.5 0 -7.2 -7.4 11/06/2005 14:20:00 7.9 1.6 11.8 4.2 7.3 1.5 11.1 3.4 6.2 1.3 9.9 2.6 32 13 31 300 -7.5 0 -7.2 -7.6 11/06/2005 14:30:00 6.5 1.8 13.3 2.3 6.2 1.8 13.7 2.6 5.3 1.7 10.7 2.3 23 16 11 300 -7.4 0 -7.2 -7.6 11/06/2005 14:40:00 4.8 1.3 8 1.5 4.8 1.3 8.8 1.9 4.3 1.2 7.2 1.5 4 21 19 300 -7.2 0 -7 -7.4 11/06/2005 14:50:00 5.3 1.3 8.8 2.3 5.2 1.3 9.5 2.3 4.5 1.3 8.8 1.9 7 16 9 300 -7.3 0 -7 -7.4 11/06/2005 15:00:00 4.2 1.1 7.2 1.9 4.2 1.2 7.6 1.9 3.4 1.1 7.2 1.5 6 17 21 300 -7.3 0 -7.2 -7.4 11/06/2005 15:10:00 4.2 1.5 8 1.5 4 1.5 8.4 1.5 3.5 1.5 8 1.1 9 18 17 300 -7.3 0.1 -7 -7.4 11/06/2005 15:20:00 4.1 1.5 6.8 0.7 3.9 1.5 6.8 0.4 3.4 1.2 5.7 0.7 12 12 25 300 -7.5 0 -7.2 -7.6 11/06/2005 15:30:00 2.9 0.9 5.3 1.1 2.8 0.9 4.9 0.7 2.4 0.8 4.9 0.7 2 15 34 300 -7.5 0.1 -7.2 -7.6 11/06/2005 15:40:00 3.7 0.8 6.1 1.9 3.5 0.8 5.7 1.5 2.8 0.8 5.3 1.5 22 13 34 300 -7.5 0 -7.2 -7.6 11/06/2005 15:50:00 2.3 0.7 4.2 0.7 2.3 0.7 4.6 0.7 2 0.6 3.8 0.7 358 17 15 300 -7.7 0 -7.6 -7.9 11/06/2005 16:00:00 2.1 0.5 3.8 0.7 2.1 0.5 3.8 0.7 2 0.5 3 0.7 351 15 357 300 -7.9 0 -7.6 -8.1 11/06/2005 16:10:00 2.5 0.8 4.2 0.4 2.5 0.8 4.2 0.4 2.2 0.6 3.4 0.7 347 10 347 300 -8 0.1 -7.6 -8.1 11/06/2005 16:20:00 1.9 0.8 3.8 0.4 1.9 0.8 3.8 0.4 1.7 0.6 3.4 0.4 341 17 333 300 -8.2 0 -8.1 -8.3 11/06/2005 16:30:00 0.4 0.2 1.5 0.4 0.4 0.2 1.1 0.4 0.8 0.4 1.5 0.4 300 3 302 300 -8.2 0 -8.1 -8.5 11/06/2005 16:40:00 0.9 0.4 1.9 0.4 0.8 0.4 1.9 0.4 0.9 0.4 1.9 0.4 269 9 270 300 -8.4 0 -8.3 -8.7 11/06/2005 16:50:00 0.6 0.3 1.5 0.4 0.6 0.3 1.5 0.4 0.8 0.3 1.5 0.4 281 17 262 300 -8.7 0 -8.5 -8.7 11/06/2005 17:00:00 0.8 0.3 1.5 0.4 0.7 0.3 1.5 0.4 1 0.2 1.9 0.4 251 10 261 300 -8.8 0 -8.7 -8.9 11/06/2005 17:10:00 0.8 0.4 1.9 0.4 0.7 0.3 1.5 0.4 1 0.3 1.9 0.4 315 22 311 300 -9 0 -8.9 -9.1 11/06/2005 17:20:00 0.6 0.3 1.5 0.4 0.5 0.3 1.5 0.4 0.8 0.4 1.9 0.4 337 7 329 300 -9 0 -8.9 -9.1 11/06/2005 17:30:00 0.5 0.3 1.5 0.4 0.5 0.2 1.1 0.4 0.6 0.3 1.5 0.4 342 7 5 300 -9.4 0.1 -8.9 -9.7 11/06/2005 17:40:00 1.4 0.5 2.3 0.4 1.3 0.5 2.6 0.4 1.2 0.4 2.3 0.4 9 23 347 300 -9.6 0 -9.3 -9.7 11/06/2005 17:50:00 1.2 0.3 2.3 0.4 1.1 0.3 1.9 0.4 1.3 0.3 1.9 0.4 340 30 292 300 -10.2 0.1 -9.7 -10.6 11/06/2005 18:00:00 1.1 0.4 1.9 0.4 1 0.4 1.9 0.4 1 0.3 1.5 0.4 337 15 345 300 -10.4 0 -10.2 -10.8 11/06/2005 18:10:00 1 0.3 1.5 0.4 0.9 0.3 1.5 0.4 1.2 0.3 1.9 0.7 347 4 351 300 -10.5 0 -10.4 -10.8 11/06/2005 18:20:00 1.8 0.3 2.6 0.7 1.7 0.4 2.3 0.4 1.5 0.3 2.3 0.7 329 9 334 300 -10.9 0 -10.6 -11 11/06/2005 18:30:00 1.7 0.4 2.3 0.7 1.6 0.4 2.3 0.7 1.6 0.3 2.3 0.7 338 6 330 300 -10.9 0 -11 -11.2 11/06/2005 18:40:00 1.3 0.4 1.9 0.4 1.1 0.4 1.9 0.4 1.3 0.2 1.9 0.7 339 9 325 300 -11 0.1 -10.8 -11.4 11/06/2005 18:50:00 0.7 0.4 1.9 0.4 0.6 0.3 1.9 0.4 1.3 0.3 1.9 0.7 353 9 358 300 -11.6 0.1 -11.2 -11.8 11/06/2005 19:00:00 0.6 0.4 1.9 0.4 0.5 0.3 1.9 0.4 0.8 0.3 1.5 0.4 37 51 4 300 -11.4 0.2 -11 -11.8 11/06/2005 19:10:00 0.4 0.2 1.5 0.4 0.4 0.2 1.5 0.4 0.5 0.4 2.3 0.4 105 19 48 300 -11.1 0.2 -10.6 -11.4 11/06/2005 19:20:00 0.4 0.2 1.1 0.4 0.4 0.2 1.1 0.4 1 0.3 1.5 0.4 86 20 97 300 -11.3 0.1 -11 -11.4 11/06/2005 19:30:00 0.4 0.1 1.1 0.4 0.4 0.1 0.7 0.4 1.2 0.2 1.9 0.4 68 0 68 300 -11.1 0 -11 -11.4 11/06/2005 19:40:00 1.3 0.7 3 0.4 1.2 0.6 2.6 0.4 1.5 0.4 2.3 0.7 56 12 41 300 -11.5 0.1 -11 -11.8 11/06/2005 19:50:00 2.2 0.6 3.4 0.4 2.1 0.6 3 0.4 1.9 0.5 3 0.7 35 10 57 300 -11.1 0.3 -10.6 -11.8 11/06/2005 20:00:00 1.7 0.4 2.6 0.7 1.4 0.4 2.3 0.4 1.5 0.4 2.6 0.7 32 13 37 300 -10.8 0 -10.6 -11 11/06/2005 20:10:00 1.1 0.7 2.6 0.4 1.1 0.7 3 0.4 1.6 0.4 2.6 1.1 44 4 49 300 -10.7 0 -10.6 -11 11/06/2005 20:20:00 2.2 0.5 3.4 0.7 2 0.6 4.2 0.4 1.6 0.5 3 0.7 19 9 23 300 -10.9 0 -10.6 -11 11/06/2005 20:30:00 1.3 0.7 2.6 0.4 1.2 0.7 2.6 0.4 1.1 0.5 2.3 0.4 31 9 24 300 -10.8 0.1 -10.6 -11 11/06/2005 20:40:00 2.1 0.5 3.4 0.7 1.9 0.5 3 0.4 1.6 0.3 2.3 0.7 33 8 31 300 -11 0 -10.8 -11.2 11/06/2005 20:50:00 2.8 0.3 3.8 1.9 2.5 0.4 3.8 1.5 1.9 0.4 3 1.1 29 7 36 300 -11.2 0 -11 -11.4 11/06/2005 21:00:00 2.7 0.6 4.2 1.1 2.4 0.6 4.2 0.7 1.9 0.5 3.4 0.4 29 8 28 300 -11.3 0 -11.2 -11.4 11/06/2005 21:10:00 2.7 0.6 4.2 0.7 2.5 0.6 3.8 0.4 1.6 0.6 3.4 0.4 32 13 44 300 -11.5 0 -11.4 -11.8 11/06/2005 21:20:00 3 0.4 3.8 1.5 2.6 0.5 3.4 1.1 1.7 0.6 3 0.4 26 9 30 300 -11.7 0 -11.6 -11.8 11/06/2005 21:30:00 2.5 0.7 3.8 0.7 2.1 0.6 3.8 0.4 1.6 0.5 3 0.4 28 7 24 300 -11.7 0 -11.6 -11.8 11/06/2005 21:40:00 2.4 0.5 3.4 1.1 2.1 0.5 3.4 0.7 1.3 0.5 2.6 0.4 29 10 37 300 -11.7 0.1 -11.6 -11.8 11/06/2005 21:50:00 2.7 0.5 3.8 1.1 2.4 0.5 3.8 1.1 1.6 0.6 3 0.4 27 14 34 300 -11.9 0 -11.8 -12 11/06/2005 22:00:00 2.3 0.5 3.4 0.7 2 0.5 3 0.4 1.6 0.4 3 0.7 28 9 34 300 -12 0 -11.8 -12.2 11/06/2005 22:10:00 2.5 0.3 3.4 1.9 2.3 0.4 3.4 1.5 1.7 0.4 2.6 0.7 19 9 20 300 -12.1 0 -12 -12.2 11/06/2005 22:20:00 3 0.5 4.2 1.9 3 0.5 4.2 1.5 2.2 0.5 3.8 1.1 5 8 2 300 -12.4 0.1 -12.2 -12.6 11/06/2005 22:30:00 3.1 0.5 4.6 1.9 3 0.6 4.6 1.1 2.1 0.7 3.8 0.4 8 10 16 300 -12.5 0 -12.4 -12.6 11/06/2005 22:40:00 3.2 0.6 4.9 1.9 2.9 0.7 4.9 1.5 2.2 0.6 4.2 0.7 17 10 20 300 -12.6 0 -12.6 -12.6 11/06/2005 22:50:00 3.2 0.7 4.9 0.7 2.8 0.7 4.6 0.4 2 0.7 3.4 0.4 19 12 26 300 -12.8 0.1 -12.6 -13.2 11/06/2005 23:00:00 2.9 0.7 4.6 1.1 2.7 0.8 4.6 0.4 1.9 0.7 3.8 0.4 14 10 30 300 -13.1 0 -13 -13.2 11/06/2005 23:10:00 2.9 0.5 4.2 1.5 2.8 0.6 4.2 1.5 2 0.5 3.4 0.7 11 10 23 300 -13.1 0 -13 -13.2 11/06/2005 23:20:00 3.3 0.6 4.6 1.5 3.2 0.7 4.9 1.1 2.5 0.7 4.6 0.7 12 8 13 300 -13.1 0 -13.2 -13.2 11/06/2005 23:30:00 3.8 0.6 5.7 1.9 3.5 0.7 5.7 1.9 2.7 0.7 4.6 1.1 14 9 11 300 -13.2 0 -13.2 -13.4 11/06/2005 23:40:00 3.9 0.6 5.3 2.3 3.6 0.7 5.3 1.5 2.8 0.6 4.6 1.1 14 9 18 300 -13.3 0 -13.2 -13.4 11/06/2005 23:50:00 3.5 0.5 4.9 1.9 3.3 0.6 4.9 1.9 2.5 0.5 4.2 1.5 14 8 21 300 -13.2 0 -13.2 -13.2 11/07/2005 00:00:00 3.3 0.5 4.6 1.9 3 0.6 4.6 1.5 2.4 0.6 3.8 0.7 16 8 12 300 -13.2 0 -13.2 -13.2 11/07/2005 00:10:00 2.5 0.5 3.8 1.1 2.2 0.6 3.8 0.7 1.7 0.5 3 0.7 17 10 7 300 -13.2 0 -13.2 -13.4 11/07/2005 00:20:00 2.1 0.5 3.4 0.7 1.9 0.6 3.4 0.7 1.3 0.5 2.6 0.4 6 11 4 300 -13.4 0.1 -13.2 -13.6 11/07/2005 00:30:00 2.7 0.5 4.2 1.1 2.7 0.5 4.2 1.1 1.7 0.5 3.4 0.4 4 7 9 300 -13.7 0 -13.6 -13.8 11/07/2005 00:40:00 2.5 0.5 3.8 0.7 2.5 0.6 3.8 0.7 1.3 0.6 2.6 0.4 356 9 358 300 -13.7 0 -13.6 -14 11/07/2005 00:50:00 2.4 0.4 3.4 1.1 2.3 0.5 3.4 0.7 1.4 0.6 3 0.4 4 9 0 300 -13.8 0 -13.6 -14 11/07/2005 01:00:00 2.6 0.5 3.8 1.5 2.5 0.6 3.8 1.1 1.6 0.5 3.4 0.7 3 9 2 300 -13.9 0.1 -13.6 -14 11/07/2005 01:10:00 2.5 0.6 3.8 1.1 2.5 0.6 4.2 0.7 1.7 0.5 3 0.4 358 8 8 300 -14.1 0 -14 -14.2 11/07/2005 01:20:00 2.8 0.4 4.2 1.9 2.8 0.4 4.2 1.9 1.9 0.4 3 0.7 9 6 9 300 -14.2 0 -14 -14.2 11/07/2005 01:30:00 2 1 3.4 0.4 2 1.1 3.8 0.4 1.3 0.8 3 0.4 6 9 9 300 -14.3 0.1 -14 -14.6 11/07/2005 01:40:00 1 0.5 2.3 0.4 0.8 0.5 2.3 0.4 0.5 0.3 1.9 0.4 13 13 6 300 -14.9 0 -14.6 -15 11/07/2005 01:50:00 1.1 0.5 1.9 0.4 0.9 0.5 1.9 0.4 1 0.5 2.3 0.4 356 11 346 300 -14.9 0 -14.8 -15 11/07/2005 02:00:00 2.2 0.4 3.4 1.5 2.2 0.4 3.4 1.5 1.8 0.3 2.6 1.1 349 4 355 300 -14.8 0 -14.6 -15 11/07/2005 02:10:00 3.6 0.5 4.6 2.3 3.7 0.5 4.6 2.3 2.8 0.5 3.8 1.9 357 4 359 300 -15.1 0.1 -14.8 -15.3 11/07/2005 02:20:00 2 1.5 4.6 0.4 1.9 1.5 4.6 0.4 1.4 1.1 3.8 0.4 327 51 1 300 -15.4 0.1 -15.1 -15.7 11/07/2005 02:30:00 1.8 0.7 3.8 0.7 1.7 0.8 3.8 0.4 1.1 0.7 3 0.4 347 9 357 300 -15.9 0 -15.5 -15.9 11/07/2005 02:40:00 2.9 0.3 3.4 1.9 2.9 0.3 3.4 1.9 2 0.4 2.6 0.7 355 4 353 300 -15.8 0.1 -15.5 -15.9 11/07/2005 02:50:00 3.4 0.3 4.2 2.6 3.5 0.3 4.2 2.6 2.5 0.4 3.4 1.1 5 3 8 300 -15.9 0 -15.7 -15.9 11/07/2005 03:00:00 3.7 0.3 4.2 2.6 3.7 0.4 4.2 2.6 2.8 0.4 3.8 1.5 358 3 359 300 -15.8 0 -15.5 -15.9 11/07/2005 03:10:00 2.1 1.1 3.8 0.4 2.1 1.2 3.8 0.4 1.3 0.9 3.4 0.4 344 14 0 300 -15.9 0 -15.5 -16.1 11/07/2005 03:20:00 1.1 0.5 2.3 0.4 0.9 0.5 2.3 0.4 0.7 0.4 1.9 0.4 331 18 334 300 -16 0 -15.9 -16.3 11/07/2005 03:30:00 0.8 0.5 2.3 0.4 0.7 0.5 2.3 0.4 0.4 0.1 1.1 0.4 332 8 339 300 -16.4 0 -16.1 -16.5 11/07/2005 03:40:00 2.6 0.5 3.4 1.1 2.6 0.6 3.4 0.7 1.8 0.6 3.4 0.4 346 5 353 300 -16.4 0 -16.3 -16.5 11/07/2005 03:50:00 2.9 0.3 3.8 2.3 2.9 0.3 3.8 2.3 2.8 0.3 3.4 1.9 324 8 339 300 -16.2 0 -15.9 -16.5 11/07/2005 04:00:00 2.6 0.3 3 1.9 2.6 0.3 3 1.9 2.5 0.3 3 1.9 321 9 319 300 -16.1 0.1 -15.9 -16.3 11/07/2005 04:10:00 2.2 0.3 3 1.5 2.1 0.3 3 1.5 2.1 0.3 2.6 1.1 302 10 288 300 -16.3 0 -16.1 -16.5 11/07/2005 04:20:00 1.7 0.4 3 0.7 1.5 0.5 3 0.4 1.4 0.4 2.3 0.7 280 9 276 300 -16.5 0.2 -16.3 -17.1 11/07/2005 04:30:00 1.3 0.3 2.3 0.7 1 0.4 1.9 0.4 1 0.5 2.3 0.4 275 13 277 300 -17.5 0.1 -17.1 -17.6 11/07/2005 04:40:00 1.4 0.3 1.9 0.7 1.1 0.4 1.9 0.4 1.3 0.2 2.3 0.7 299 6 297 300 -17.8 0.2 -17.4 -18 11/07/2005 04:50:00 1.4 0.3 2.3 0.7 1.2 0.3 1.9 0.4 1.1 0.3 1.9 0.4 283 8 295 300 -17.7 0.1 -17.4 -18 11/07/2005 05:00:00 1.3 0.3 1.9 0.7 1 0.3 1.9 0.4 1.3 0.3 1.9 0.7 296 7 289 300 -18 0.1 -17.6 -18.2 11/07/2005 05:10:00 1.2 0.3 2.3 0.7 1 0.3 1.9 0.4 1.4 0.3 1.9 0.7 304 10 300 300 -18.3 0.1 -18 -18.5 11/07/2005 05:20:00 0.9 0.4 1.5 0.4 0.7 0.3 1.5 0.4 0.8 0.3 1.5 0.4 277 19 299 300 -18 0 -17.8 -18.2 11/07/2005 05:30:00 1.3 0.4 2.3 0.4 1.1 0.4 2.3 0.4 1.2 0.4 2.3 0.4 281 17 312 300 -18.4 0.2 -18 -18.7 11/07/2005 05:40:00 2.3 0.5 4.6 1.5 2.3 0.5 4.2 1.1 2.3 0.3 3.8 1.5 309 12 279 300 -18.3 0.1 -18 -18.5 11/07/2005 05:50:00 2.7 0.4 3.4 1.5 2.6 0.4 3.8 1.1 2.6 0.5 3.8 1.5 314 20 323 300 -18 0 -18 -18 11/07/2005 06:00:00 2.5 0.3 3.4 1.5 2.4 0.3 3 1.5 2.2 0.4 3 1.5 293 11 296 300 -18 0 -17.8 -18 11/07/2005 06:10:00 2.2 0.5 3.4 0.4 2.1 0.5 3 0.7 1.9 0.6 3 0.4 284 12 284 300 -18.1 0.1 -17.6 -18.4 11/07/2005 06:20:00 2.4 0.7 3.8 1.1 2.3 0.7 3.8 0.7 2.2 0.6 3.4 1.1 275 16 263 300 -17.9 0.3 -17.4 -18.5 11/07/2005 06:30:00 2.7 0.3 3.4 1.9 2.6 0.3 3.4 1.9 2.2 0.4 3 0.7 275 10 263 300 -17.9 0.3 -17.4 -18.4 11/07/2005 06:40:00 3.4 0.4 4.2 2.3 3.3 0.4 4.2 2.3 3 0.4 4.2 1.9 281 6 280 300 -17.2 0.5 -16.3 -18.2 11/07/2005 06:50:00 2.7 0.8 4.6 1.1 2.6 0.8 4.6 0.7 2.2 0.8 3.8 0.7 272 16 258 300 -16.3 0.6 -15.9 -18 11/07/2005 07:00:00 1.7 0.4 2.6 0.7 1.5 0.4 2.6 0.4 1.4 0.4 2.6 0.4 293 13 296 300 -17.4 0.6 -16.3 -18 11/07/2005 07:10:00 1.8 0.6 3.4 0.4 1.6 0.7 3 0.4 1.6 0.6 3 0.4 267 15 231 300 -16.7 0.8 -15.5 -17.8 11/07/2005 07:20:00 1.6 0.6 2.6 0.4 1.4 0.6 2.6 0.4 1 0.5 2.3 0.4 249 22 237 300 -18.3 0.3 -17.8 -18.7 11/07/2005 07:30:00 0.6 0.3 1.5 0.4 0.5 0.2 1.5 0.4 0.5 0.2 1.1 0.4 250 3 250 300 -18.4 0.2 -18 -18.5 11/07/2005 07:40:00 1.1 0.5 2.6 0.4 0.9 0.5 2.6 0.4 0.5 0.2 1.5 0.4 247 15 263 300 -18.8 0.2 -18.2 -19.1 11/07/2005 07:50:00 0.4 0.2 1.1 0.4 0.4 0.2 1.1 0.4 0.4 0.1 1.1 0.4 223 0 223 300 -19 0.3 -18.4 -19.3 11/07/2005 08:00:00 1.4 0.5 2.6 0.7 1.4 0.4 2.6 0.4 1.3 0.4 2.3 0.4 172 35 122 300 -19.2 0 -18.9 -19.4 11/07/2005 08:10:00 1.6 0.7 2.6 0.4 1.5 0.7 2.6 0.4 1.3 0.6 2.3 0.4 133 9 130 300 -19.3 0.2 -18.7 -19.6 11/07/2005 08:20:00 1 0.4 1.9 0.4 0.9 0.4 1.5 0.4 0.9 0.2 1.5 0.4 136 11 143 300 -19 0.1 -18.5 -19.1 11/07/2005 08:30:00 0.5 0.2 1.1 0.4 0.5 0.2 1.1 0.4 0.6 0.3 1.5 0.4 132 9 131 300 -19.3 0.1 -19.1 -19.4 11/07/2005 08:40:00 1.2 0.8 3.8 0.4 1.2 0.8 3.8 0.4 1.6 0.9 3.8 0.4 113 49 47 300 -19.5 0.1 -19.3 -19.8 11/07/2005 08:50:00 1.3 0.9 4.2 0.4 1.2 0.9 4.6 0.4 1.4 0.9 3.8 0.4 156 72 57 300 -19 0.3 -18.5 -19.8 11/07/2005 09:00:00 1.4 1 3.4 0.4 1.3 1 3.4 0.4 1.4 1 3.8 0.4 275 82 225 300 -18.9 0.2 -18.4 -19.1 11/07/2005 09:10:00 1.2 0.6 2.6 0.4 1 0.6 2.3 0.4 1 0.7 3.8 0.4 270 58 17 300 -17.5 0.4 -16.7 -18.5 11/07/2005 09:20:00 0.4 0.2 1.1 0.4 0.4 0.1 1.1 0.4 0.5 0.3 1.5 0.4 215 17 195 300 -17.9 0.2 -17.4 -18.4 11/07/2005 09:30:00 0.5 0.2 1.1 0.4 0.5 0.2 1.1 0.4 0.4 0.1 0.7 0.4 191 27 193 300 -18.5 0.3 -18 -18.9 11/07/2005 09:40:00 0.8 0.8 3.4 0.4 0.7 0.8 3.4 0.4 0.9 1 3.8 0.4 59 47 52 300 -18.4 0.2 -18 -18.9 11/07/2005 09:50:00 2 1.2 5.3 0.4 2 1.2 5.3 0.4 2.2 1.2 5.3 0.4 131 112 80 300 -18.1 0.2 -17.4 -18.5 11/07/2005 10:00:00 1.7 1.2 4.6 0.4 1.7 1.2 4.6 0.4 1.5 1.1 4.6 0.4 132 94 62 300 -16.7 0.4 -15.9 -17.6 11/07/2005 10:10:00 1.5 1.4 5.3 0.4 1.5 1.4 5.3 0.4 1.6 1.3 5.3 0.4 285 45 46 300 -16.2 0.3 -15.5 -17.1 11/07/2005 10:20:00 2 1.5 6.1 0.4 1.8 1.5 5.7 0.4 1.6 1.2 5.3 0.4 295 56 33 300 -15.3 0.4 -14.6 -15.9 11/07/2005 10:30:00 0.9 0.6 2.6 0.4 0.8 0.5 2.3 0.4 0.8 0.5 1.9 0.4 175 56 101 300 -14.1 0.2 -13.6 -14.6 11/07/2005 10:40:00 1.4 1.2 4.2 0.4 1.4 1.2 4.2 0.4 1.5 1.1 4.2 0.4 96 36 61 300 -13.6 0.2 -13.2 -14 11/07/2005 10:50:00 1.2 0.5 2.3 0.4 1.1 0.5 2.3 0.4 1.2 0.5 2.3 0.4 145 30 161 300 -13.4 0.3 -12.6 -13.8 11/07/2005 11:00:00 1.3 0.9 3.4 0.4 1.2 0.9 3 0.4 1.3 0.9 3.4 0.4 86 47 57 300 -12.7 0.1 -12.4 -13 11/07/2005 11:10:00 1.3 0.7 3 0.4 1.3 0.7 3 0.4 1.2 0.7 3 0.4 116 56 57 300 -12.5 0.1 -12.2 -12.8 11/07/2005 11:20:00 0.7 0.3 1.5 0.4 0.6 0.3 1.5 0.4 0.8 0.4 1.9 0.4 76 23 73 300 -12.2 0.2 -11.8 -12.4 11/07/2005 11:30:00 0.8 0.6 2.6 0.4 0.8 0.6 3 0.4 0.9 0.6 3 0.4 108 66 163 300 -11.9 0.3 -11.4 -12.4 11/07/2005 11:40:00 1.5 0.3 2.3 0.7 1.4 0.3 2.3 0.7 1.5 0.4 2.3 0.4 181 14 192 300 -11.8 0.2 -11.4 -12.2 11/07/2005 11:50:00 1.5 0.5 2.6 0.4 1.5 0.5 2.6 0.4 1.6 0.6 3 0.4 156 22 140 300 -11.7 0.2 -11.2 -12 11/07/2005 12:00:00 1.7 0.5 3 0.4 1.6 0.5 3 0.4 1.6 0.5 2.6 0.4 174 17 164 300 -11.6 0.2 -11.2 -11.8 11/07/2005 12:10:00 1.6 0.5 3 0.4 1.6 0.5 3 0.4 1.6 0.5 2.6 0.4 182 19 176 300 -11.8 0.1 -11.4 -12 11/07/2005 12:20:00 1 0.5 2.3 0.4 1 0.5 2.3 0.4 1.2 0.4 2.6 0.4 226 38 236 300 -11.7 0.1 -11.4 -12 11/07/2005 12:30:00 1.5 0.6 3.4 0.4 1.5 0.7 3.4 0.4 1.5 0.6 3 0.4 207 26 199 300 -11.4 0 -11.2 -11.4 11/07/2005 12:40:00 1.6 0.6 2.6 0.4 1.5 0.6 2.6 0.4 1.6 0.6 2.6 0.4 180 24 181 300 -11.5 0 -11.4 -11.6 11/07/2005 12:50:00 1.6 0.5 3 0.4 1.6 0.5 3 0.4 1.6 0.4 2.6 0.4 176 24 185 300 -11.4 0.1 -11.2 -11.8 11/07/2005 13:00:00 1.8 0.6 3.4 0.4 1.7 0.6 3.4 0.4 1.7 0.7 3 0.4 158 11 171 300 -11.3 0.1 -11 -11.4 11/07/2005 13:10:00 2.2 0.6 3.4 0.4 2.3 0.6 3.4 0.4 2.3 0.6 3.4 0.4 191 11 195 300 -11 0.2 -10.8 -11.4 11/07/2005 13:20:00 1.9 0.8 3.8 0.4 1.9 0.8 3.8 0.4 1.8 0.7 3.4 0.4 193 17 180 300 -11.4 0 -11.2 -11.4 11/07/2005 13:30:00 1.7 0.6 3 0.4 1.7 0.5 3 0.4 1.8 0.4 3 0.7 232 17 240 300 -11.2 0 -11 -11.4 11/07/2005 13:40:00 1 0.6 2.6 0.4 1 0.6 2.6 0.4 1.1 0.5 3 0.4 180 39 206 300 -10.9 0.1 -10.6 -11.2 11/07/2005 13:50:00 0.8 0.5 2.3 0.4 0.8 0.6 2.6 0.4 0.9 0.5 2.3 0.4 210 18 216 300 -10.7 0.1 -10.6 -11 11/07/2005 14:00:00 0.9 0.4 1.9 0.4 0.9 0.4 1.9 0.4 0.9 0.5 1.9 0.4 201 22 197 300 -10.5 0 -10.4 -10.6 11/07/2005 14:10:00 0.9 0.4 1.9 0.4 0.8 0.4 2.3 0.4 1 0.5 2.3 0.4 224 28 224 300 -10.5 0.1 -10.4 -10.8 11/07/2005 14:20:00 0.9 0.5 2.3 0.4 0.8 0.5 1.9 0.4 0.9 0.5 2.3 0.4 229 32 233 300 -10.7 0.1 -10.2 -11 11/07/2005 14:30:00 1 0.4 1.9 0.4 1 0.5 2.3 0.4 1.2 0.4 2.3 0.4 188 13 182 300 -10.4 0.1 -10.2 -10.8 11/07/2005 14:40:00 0.5 0.3 1.5 0.4 0.5 0.3 1.5 0.4 0.6 0.3 1.5 0.4 188 72 192 300 -10.4 0.2 -10 -10.8 11/07/2005 14:50:00 0.8 0.4 1.9 0.4 0.7 0.4 1.9 0.4 0.9 0.4 1.9 0.4 225 10 209 300 -10.7 0.1 -10.4 -11 11/07/2005 15:00:00 0.4 0.2 1.1 0.4 0.5 0.2 1.1 0.4 0.6 0.4 1.9 0.4 218 13 222 300 -10.9 0 -10.6 -11 11/07/2005 15:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 226 0 300 300 -10 0.3 -9.7 -10.6 11/07/2005 15:20:00 0.4 0.1 1.1 0.4 0.4 0.1 0.7 0.4 0.4 0.2 1.5 0.4 200 23 171 300 -10 0.2 -9.7 -10.6 11/07/2005 15:30:00 0.4 0.2 1.1 0.4 0.4 0.2 1.1 0.4 0.4 0.2 1.1 0.4 181 0 181 300 -11 0.1 -10.6 -11.2 11/07/2005 15:40:00 0.5 0.3 1.5 0.4 0.5 0.2 1.1 0.4 0.5 0.3 1.5 0.4 177 5 175 300 -11.2 0.2 -11 -11.6 11/07/2005 15:50:00 0.5 0.2 1.5 0.4 0.6 0.3 1.5 0.4 0.7 0.4 1.5 0.4 185 13 198 300 -11.8 0.2 -11.4 -12.2 11/07/2005 16:00:00 0.8 0.4 1.5 0.4 0.7 0.3 1.5 0.4 0.8 0.4 1.5 0.4 189 3 198 300 -12.2 0 -12 -12.4 11/07/2005 16:10:00 0.4 0.1 1.1 0.4 0.4 0.1 1.1 0.4 0.4 0.2 1.1 0.4 187 0 187 300 -12.3 0.2 -12 -12.6 11/07/2005 16:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 187 0 300 300 -12.9 0.2 -12.6 -13.2 11/07/2005 16:30:00 0.4 0 0.4 0.4 0.4 0 0.7 0.4 0.4 0.1 0.7 0.4 146 26 300 300 -13.4 0.1 -13.2 -13.6 11/07/2005 16:40:00 0.4 0 0.7 0.4 0.4 0.1 0.7 0.4 0.4 0.1 1.1 0.4 126 4 121 300 -13.9 0.2 -13.6 -14.2 11/07/2005 16:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 121 0 300 300 -14.5 0.1 -14 -14.6 11/07/2005 17:00:00 0.4 0 0.4 0.4 0.4 0.1 0.7 0.4 0.4 0 0.4 0.4 117 12 300 300 -14.8 0 -14.6 -15.1 11/07/2005 17:10:00 0.9 0.4 1.5 0.4 0.9 0.3 1.5 0.4 0.9 0.3 1.5 0.4 73 5 74 300 -15.1 0.2 -14.8 -15.3 11/07/2005 17:20:00 1.8 0.3 2.6 1.1 1.7 0.3 2.6 1.1 1.3 0.3 1.9 0.4 42 5 31 300 -15.5 0.1 -15.3 -15.9 11/07/2005 17:30:00 2.1 0.2 2.6 1.9 2.1 0.2 2.6 1.9 2 0.3 2.3 1.1 38 3 39 300 -15.6 0 -15.5 -15.9 11/07/2005 17:40:00 2.1 0.2 2.6 1.5 2 0.2 2.6 1.5 1.8 0.3 2.3 1.1 35 1 36 300 -15.8 0 -15.5 -15.9 11/07/2005 17:50:00 2 0.2 2.3 1.5 2 0.2 2.3 1.5 1.6 0.3 1.9 0.7 43 5 36 300 -16.1 0.4 -15.5 -16.7 11/07/2005 18:00:00 2.6 0.3 3 1.9 2.6 0.3 3 1.9 2.1 0.4 2.6 1.5 54 4 52 300 -16.9 0.1 -16.5 -17.1 11/07/2005 18:10:00 2.5 0.2 2.6 2.3 2.5 0.2 3 2.3 2.2 0.2 2.6 1.9 54 2 53 300 -17 0 -17.1 -17.1 11/07/2005 18:20:00 2.6 0.3 3 2.3 2.6 0.3 3 2.3 2.2 0.2 2.6 1.9 56 0 56 300 -17 0 -16.9 -17.1 11/07/2005 18:30:00 2.7 0.2 3 2.3 2.7 0.2 3 2.3 2.4 0.2 2.6 1.9 45 8 56 300 -17.1 0 -16.9 -17.2 11/07/2005 18:40:00 3.1 0.3 3.4 2.3 3 0.3 3.4 2.3 2.2 0.2 2.6 1.5 29 1 28 300 -17.1 0.1 -16.9 -17.4 11/07/2005 18:50:00 2.8 0.4 3.4 1.9 2.6 0.4 3.4 1.5 1.9 0.3 2.6 1.1 27 3 28 300 -17.5 0 -17.4 -17.4 11/07/2005 19:00:00 2.2 0.3 3 1.5 2.1 0.3 3 1.5 1.5 0.2 1.9 1.1 35 2 36 300 -17.7 0 -17.4 -17.8 11/07/2005 19:10:00 2.9 0.4 3.8 2.3 2.7 0.3 3.4 1.9 1.7 0.2 2.3 1.1 29 3 23 300 -17.8 0.1 -17.4 -18 11/07/2005 19:20:00 2.6 0.3 3.4 1.9 2.6 0.3 3.4 1.9 1.7 0.3 2.3 1.1 34 4 36 300 -17.5 0.1 -17.2 -18 11/07/2005 19:30:00 1.4 0.8 2.6 0.4 1.2 0.7 2.6 0.4 1.1 0.4 2.3 0.4 36 5 28 300 -17.8 0.2 -17.4 -18 11/07/2005 19:40:00 1.4 0.6 2.3 0.4 1.3 0.6 2.3 0.4 1.6 0.3 2.3 0.7 71 19 85 300 -17.8 0.2 -17.4 -18 11/07/2005 19:50:00 2 0.2 2.3 1.5 1.9 0.2 2.3 1.5 1.8 0.3 2.3 1.5 74 10 91 300 -18 0.3 -17.2 -18.5 11/07/2005 20:00:00 2 0.2 2.3 1.5 1.9 0.2 2.3 1.5 2.1 0.2 2.6 1.5 53 2 61 300 -17.6 0.2 -17.1 -17.8 11/07/2005 20:10:00 2.5 0.2 3 1.9 2.5 0.2 3 1.9 2.1 0.2 2.6 1.9 58 2 62 300 -17.5 0 -17.4 -17.4 11/07/2005 20:20:00 2.7 0.2 3 2.3 2.7 0.2 3 2.3 2.3 0.2 2.6 1.9 56 2 56 300 -17.1 0.2 -16.9 -17.4 11/07/2005 20:30:00 2.7 0.2 3 2.3 2.7 0.2 3 2.3 2.4 0.2 3 1.9 57 4 55 300 -17 0 -16.9 -17.1 11/07/2005 20:40:00 2.8 0.2 3.4 2.3 2.8 0.2 3.4 2.3 2.6 0.3 3 1.9 48 3 52 300 -17.1 0 -16.7 -17.2 11/07/2005 20:50:00 2.9 0.2 3.4 2.3 3 0.2 3.4 2.3 2.5 0.2 3 1.9 46 4 51 300 -17.2 0 -17.1 -17.4 11/07/2005 21:00:00 3.1 0.2 3.4 2.6 3.1 0.2 3.4 2.6 2.7 0.3 3.4 2.3 43 4 45 300 -17.3 0.1 -17.1 -17.4 11/07/2005 21:10:00 2.9 0.4 3.8 2.3 2.9 0.4 3.8 2.3 2.8 0.3 3.4 2.3 51 5 56 300 -16.7 0.1 -16.3 -17.1 11/07/2005 21:20:00 3.7 0.2 4.2 3 3.6 0.3 4.2 2.6 2.8 0.5 3.8 1.5 41 7 46 300 -16.6 0.2 -16.3 -16.9 11/07/2005 21:30:00 3.8 0.3 4.6 3 3.6 0.5 4.6 2.3 2.5 0.5 3.8 1.1 33 4 39 300 -17 0.1 -16.7 -17.2 11/07/2005 21:40:00 4.7 0.5 6.5 3.4 4.4 0.7 6.1 3 3 0.6 4.9 1.5 35 8 33 300 -17.1 0.3 -16.1 -17.4 11/07/2005 21:50:00 4.6 0.8 7.6 3 4.3 0.9 6.5 2.3 3.1 0.8 7.2 1.1 37 10 39 300 -15.6 0.2 -15 -16.1 11/07/2005 22:00:00 6 1 8.4 3.8 5.7 1 8.4 3 4.3 1 7.2 1.9 39 9 35 300 -14.6 0.1 -14.2 -15 11/07/2005 22:10:00 6.1 1.2 8.8 3.4 5.8 1.2 8.4 2.6 4.3 1.4 8 0.7 38 12 42 300 -13.7 0.2 -13.2 -14.2 11/07/2005 22:20:00 6.1 1.1 9.1 3.4 5.8 1.2 9.5 3 4.8 1.1 8 1.9 39 10 43 300 -13.1 0.1 -12.8 -13.4 11/07/2005 22:30:00 6.9 1.5 9.9 2.6 6.4 1.5 9.1 2.3 5.2 1.2 8.8 1.9 36 13 15 300 -12.7 0.1 -12.6 -13 11/07/2005 22:40:00 7.4 1.2 9.9 4.9 7 1.2 10.3 3.4 5.5 1.3 9.1 2.6 34 14 43 300 -12.5 0 -12.4 -12.6 11/07/2005 22:50:00 8.1 1.6 12.6 3.8 7.8 1.7 13 3.4 6.2 1.7 12.2 1.9 38 13 41 300 -12.5 0 -12.4 -12.6 11/07/2005 23:00:00 8.1 1.9 13.3 3.4 7.6 1.9 13.3 3 6 1.9 13 1.9 38 15 45 300 -12.5 0 -12.4 -12.6 11/07/2005 23:10:00 8.9 1.6 12.2 4.9 8.6 1.7 12.6 4.9 6.8 1.7 11.8 2.3 39 13 37 300 -12.5 0 -12.4 -12.6 11/07/2005 23:20:00 9.3 2 13.7 2.3 9 2 13.7 2.6 7.1 1.8 12.2 2.6 38 15 46 300 -12.6 0 -12.6 -12.6 11/07/2005 23:30:00 10 1.7 14.1 4.6 9.7 1.8 14.1 3.8 7.4 1.7 12.6 3 40 11 39 300 -12.5 0 -12.4 -12.6 11/07/2005 23:40:00 7.6 1.7 12.6 2.6 7.5 1.8 12.6 2.6 5.9 1.5 11.5 1.9 47 15 51 300 -12.5 0 -12.4 -12.6 11/07/2005 23:50:00 7.3 1.7 12.2 2.6 7.3 1.7 12.2 2.6 5.8 1.8 10.7 1.9 49 20 57 300 -12.5 0 -12.4 -12.6 11/08/2005 00:00:00 8.3 1.7 11.8 3.4 8.2 1.8 12.2 3.4 6.4 2 10.7 1.9 50 15 45 300 -12.5 0 -12.4 -12.6 11/08/2005 00:10:00 9.2 2 13.7 3.4 9.3 2.1 13.7 3.4 7.4 2.3 13 2.6 52 13 45 300 -12.4 0 -12.4 -12.6 11/08/2005 00:20:00 8.1 1.8 12.2 3 8 2 12.6 3 6.4 2 10.7 1.5 51 17 47 300 -12.4 0 -12.2 -12.4 11/08/2005 00:30:00 7.7 1.8 11.8 1.5 7.8 1.9 12.2 2.6 6.3 2 11.8 1.9 52 17 61 300 -12.2 0 -12 -12.4 11/08/2005 00:40:00 7.6 2 13 2.6 7.4 2.1 13 2.3 6 1.7 10.7 1.5 49 17 69 300 -12.1 0 -12 -12.2 11/08/2005 00:50:00 6.7 1.5 10.7 3 6.6 1.5 10.7 2.6 5.2 1.5 8.8 1.1 51 17 40 300 -12 0 -12 -12.2 11/08/2005 01:00:00 7.4 1.5 11.8 3 7.4 1.6 11.8 3.4 5.8 1.6 9.9 2.3 48 15 64 300 -12 0 -11.8 -12 11/08/2005 01:10:00 8.1 1.8 13.3 3.4 7.9 1.9 13 3.4 6.1 2.1 11.1 1.9 47 16 30 300 -12 0 -11.8 -12 11/08/2005 01:20:00 8.5 1.7 12.6 3 8.4 1.7 12.6 2.3 6.6 1.8 11.8 1.9 47 12 55 300 -11.9 0 -11.8 -12 11/08/2005 01:30:00 9.1 1.7 13.7 3.8 9.1 1.8 13.7 3.8 7.2 1.8 11.8 2.6 49 12 55 300 -11.9 0 -11.8 -12 11/08/2005 01:40:00 9.2 1.9 14.1 3.8 9 2.1 14.1 3.4 6.8 2 13 2.3 46 15 22 300 -11.9 0 -11.8 -12 11/08/2005 01:50:00 9.8 1.8 14.5 4.9 9.8 2 14.5 4.2 7.7 2.1 12.6 2.3 44 13 34 300 -11.9 0 -11.8 -12 11/08/2005 02:00:00 8.5 2 13.7 3.4 8.5 2.2 14.1 3 6.5 2.5 12.2 1.5 52 16 52 300 -11.8 0 -11.8 -12 11/08/2005 02:10:00 6.5 1.7 11.8 1.9 6.5 1.9 12.2 1.5 5.1 1.7 9.9 1.5 52 16 69 300 -11.7 0 -11.6 -11.8 11/08/2005 02:20:00 6.8 1.7 11.8 3 6.8 1.8 12.2 2.6 5.3 1.7 9.9 1.9 53 18 51 300 -11.7 0 -11.8 -11.8 11/08/2005 02:30:00 7.6 1.9 12.2 3 7.5 2.1 12.6 2.6 5.7 1.9 12.6 1.5 47 15 45 300 -11.7 0 -11.6 -11.8 11/08/2005 02:40:00 6.1 2.2 13 1.9 6 2.2 12.2 1.5 4.6 1.8 11.1 0.7 52 24 38 300 -11.6 0 -11.6 -11.8 11/08/2005 02:50:00 4.8 1.4 8.4 1.1 4.8 1.5 9.1 0.7 4.1 1.2 7.6 1.5 65 17 49 300 -12 0.3 -11.6 -12.4 11/08/2005 03:00:00 4.5 1.4 8 1.9 4.4 1.4 8 1.1 3.8 1.2 7.6 1.9 65 26 50 300 -12.3 0.1 -12 -12.6 11/08/2005 03:10:00 5.2 2.3 11.1 0.4 5.1 2.4 11.8 1.1 4.4 1.9 9.9 1.1 54 26 49 300 -12.3 0.3 -11.6 -12.8 11/08/2005 03:20:00 7.4 1.8 11.8 3 7.2 1.9 12.2 2.6 5.6 1.7 10.3 1.9 48 16 21 300 -11.5 0 -11.4 -11.8 11/08/2005 03:30:00 7.1 1.5 11.8 3 7 1.6 11.5 2.6 5.6 1.6 10.3 1.9 49 13 33 300 -11.1 0 -11 -11.4 11/08/2005 03:40:00 7.5 1.8 11.5 3 7.4 2 11.5 2.6 5.7 2.1 10.3 1.5 49 15 58 300 -10.9 0 -11 -11 11/08/2005 03:50:00 6.1 1.7 10.3 2.3 6.1 1.8 9.9 1.5 4.8 1.6 9.9 0.7 52 15 43 300 -10.9 0 -11 -11 11/08/2005 04:00:00 5.3 1.3 8.8 1.9 5.3 1.3 8.8 1.5 4.3 1.3 7.6 1.5 56 17 48 300 -11.1 0 -11 -11.2 11/08/2005 04:10:00 4.9 1.3 8 0.4 4.7 1.3 8 1.1 3.6 1.2 7.2 0.7 41 17 54 300 -11.2 0 -11 -11.4 11/08/2005 04:20:00 5 1.3 8 1.9 4.7 1.3 8 1.1 3.7 1.2 7.2 0.4 41 17 26 300 -11.2 0 -11.2 -11.4 11/08/2005 04:30:00 4.7 1.3 8.8 1.5 4.5 1.3 8.8 1.1 3.6 1.2 6.5 0.7 49 21 50 300 -11.2 0 -11 -11.4 11/08/2005 04:40:00 4.7 1.1 7.6 1.9 4.6 1.2 7.6 1.9 3.7 1 6.5 1.1 53 18 32 300 -11.2 0 -11.2 -11.4 11/08/2005 04:50:00 3.5 1.1 6.5 1.1 3.4 1.2 6.1 0.7 2.9 1 6.1 0.7 59 19 44 300 -11.4 0 -11.2 -11.4 11/08/2005 05:00:00 3.3 1.1 6.8 1.5 3.3 1.2 6.5 1.5 2.8 1 6.1 0.7 65 14 85 300 -11.7 0.1 -11.4 -11.8 11/08/2005 05:10:00 3.7 0.8 6.1 1.9 3.7 0.8 6.5 1.5 3.3 0.7 5.3 1.9 62 13 60 300 -11.9 0 -11.8 -12 11/08/2005 05:20:00 3.4 0.9 4.9 1.1 3.3 1 5.3 0.7 2.7 0.8 5.7 1.1 62 16 60 300 -11.9 0 -11.8 -12 11/08/2005 05:30:00 2.3 0.5 3.8 1.1 2.2 0.6 3.8 0.7 1.8 0.5 3.4 0.7 85 18 36 300 -12.5 0.3 -12 -13 11/08/2005 05:40:00 1.8 0.5 3.4 0.4 1.6 0.5 3 0.4 1.2 0.5 2.3 0.4 87 12 71 300 -13 0 -12.8 -13.2 11/08/2005 05:50:00 2 0.4 3.4 0.7 1.9 0.4 3.4 0.7 1.3 0.4 2.6 0.4 66 11 72 300 -13.1 0 -12.8 -13.2 11/08/2005 06:00:00 2 0.5 3.4 0.7 1.9 0.6 3.4 0.4 1.3 0.5 3 0.4 71 14 67 300 -13 0 -12.8 -13.2 11/08/2005 06:10:00 1.4 0.4 2.3 0.4 1.1 0.4 2.3 0.4 0.8 0.4 1.9 0.4 68 13 60 300 -13.2 0 -13.2 -13.4 11/08/2005 06:20:00 1.6 0.3 2.3 0.7 1.3 0.4 2.3 0.4 0.9 0.4 1.9 0.4 75 7 85 300 -13.2 0 -13.2 -13.4 11/08/2005 06:30:00 0.9 0.4 1.5 0.4 0.7 0.3 1.1 0.4 0.4 0.2 1.1 0.4 86 15 77 300 -12.9 0.1 -12.6 -13.2 11/08/2005 06:40:00 0.4 0.1 1.1 0.4 0.4 0 0.7 0.4 0.4 0.1 0.7 0.4 70 8 69 300 -13 0 -12.8 -13.2 11/08/2005 06:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 67 0 300 300 -13 0 -12.8 -13.2 11/08/2005 07:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 62 4 300 300 -12.9 0 -12.8 -13 11/08/2005 07:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 59 0 300 300 -12.8 0 -12.6 -13 11/08/2005 07:20:00 0.4 0 0.7 0.4 0.4 0 0.7 0.4 0.4 0 0.4 0.4 59 0 59 300 -12.8 0 -12.6 -13 11/08/2005 07:30:00 0.5 0.2 1.5 0.4 0.4 0.1 0.7 0.4 0.5 0.2 1.5 0.4 86 9 98 300 -12.7 0 -12.6 -12.6 11/08/2005 07:40:00 0.7 0.3 1.5 0.4 0.5 0.2 1.1 0.4 0.6 0.3 1.5 0.4 90 2 92 300 -12.8 0 -12.6 -13 11/08/2005 07:50:00 0.7 0.3 1.5 0.4 0.4 0.2 1.5 0.4 0.8 0.3 1.5 0.4 87 10 66 300 -12.8 0 -12.6 -13 11/08/2005 08:00:00 0.7 0.4 1.5 0.4 0.5 0.2 1.5 0.4 0.7 0.3 1.9 0.4 103 39 137 300 -12.8 0 -12.6 -13 11/08/2005 08:10:00 0.7 0.5 2.3 0.4 0.6 0.4 1.9 0.4 0.5 0.4 1.9 0.4 193 9 198 300 -12.7 0 -12.6 -12.8 11/08/2005 08:20:00 1.1 0.3 1.9 0.4 0.9 0.3 1.9 0.4 0.7 0.4 1.9 0.4 208 5 212 300 -12.6 0 -12.6 -12.8 11/08/2005 08:30:00 1.1 0.2 1.5 0.7 0.7 0.2 1.1 0.4 0.5 0.2 1.1 0.4 213 0 213 300 -12.6 0 -12.6 -12.6 11/08/2005 08:40:00 0.8 0.4 1.9 0.4 0.7 0.3 1.5 0.4 0.6 0.3 1.1 0.4 210 4 204 300 -12.5 0 -12.2 -12.6 11/08/2005 08:50:00 1.1 0.4 2.3 0.4 1.1 0.4 2.3 0.4 0.8 0.4 1.9 0.4 206 6 199 300 -12.3 0 -12.2 -12.4 11/08/2005 09:00:00 0.7 0.5 2.3 0.4 0.7 0.5 2.3 0.4 0.6 0.3 1.5 0.4 209 6 219 300 -12.2 0 -12 -12.2 11/08/2005 09:10:00 0.6 0.3 1.5 0.4 0.5 0.2 1.1 0.4 0.4 0.2 1.1 0.4 209 3 216 300 -12 0 -11.8 -12.2 11/08/2005 09:20:00 0.7 0.3 1.5 0.4 0.6 0.3 1.1 0.4 0.6 0.3 1.5 0.4 205 1 206 300 -11.9 0 -11.8 -12 11/08/2005 09:30:00 1.1 0.4 1.9 0.4 0.9 0.4 1.9 0.4 0.8 0.4 1.9 0.4 228 14 227 300 -11.7 0 -11.4 -11.8 11/08/2005 09:40:00 1.5 0.3 2.3 0.7 1.4 0.4 2.3 0.4 1.3 0.5 2.3 0.4 217 9 220 300 -11.5 0 -11.4 -11.6 11/08/2005 09:50:00 1.7 0.4 3 0.7 1.9 0.5 3 0.4 1.8 0.6 3 0.4 204 8 188 300 -11.5 0 -11.4 -11.4 11/08/2005 10:00:00 1.7 0.5 2.6 0.4 1.8 0.5 3 0.4 1.8 0.4 2.6 0.4 201 10 193 300 -11.3 0 -11 -11.4 11/08/2005 10:10:00 2.2 0.5 3 0.4 2.1 0.5 3 0.4 2.1 0.4 3 0.7 189 6 191 300 -11.2 0 -11.2 -11.4 11/08/2005 10:20:00 1.2 0.5 2.6 0.4 1.2 0.6 2.3 0.4 1.1 0.6 2.3 0.4 193 12 184 300 -11.1 0 -11 -11.2 11/08/2005 10:30:00 1.2 0.6 2.6 0.4 1.1 0.6 2.6 0.4 1.1 0.6 2.3 0.4 193 10 185 300 -10.9 0 -10.6 -11 11/08/2005 10:40:00 1.7 0.4 2.6 0.4 1.5 0.4 2.6 0.4 1.6 0.4 2.6 0.4 186 11 184 300 -10.8 0 -10.6 -11 11/08/2005 10:50:00 1.2 0.6 2.6 0.4 1 0.5 2.3 0.4 1.2 0.6 2.6 0.4 191 20 181 300 -10.7 0 -10.6 -11 11/08/2005 11:00:00 0.9 0.5 1.9 0.4 0.8 0.5 1.9 0.4 0.9 0.5 2.3 0.4 200 14 188 300 -10.5 0 -10.4 -10.8 11/08/2005 11:10:00 0.8 0.5 2.3 0.4 0.7 0.5 2.3 0.4 0.8 0.4 1.9 0.4 194 17 198 300 -10.4 0 -10.2 -10.6 11/08/2005 11:20:00 1.4 0.4 3 0.4 1.2 0.5 2.6 0.4 1.2 0.5 2.3 0.4 174 15 200 300 -10.4 0 -10.2 -10.4 11/08/2005 11:30:00 1 0.5 1.9 0.4 0.8 0.5 1.9 0.4 1 0.5 2.3 0.4 193 19 151 300 -10.2 0 -10 -10.4 11/08/2005 11:40:00 1.3 0.5 2.3 0.4 1.1 0.5 2.3 0.4 1.1 0.6 2.3 0.4 210 22 231 300 -9.8 0 -9.7 -10.2 11/08/2005 11:50:00 1.1 0.5 2.3 0.4 0.9 0.5 2.3 0.4 1.2 0.5 2.6 0.4 224 16 222 300 -9.7 0 -9.7 -9.7 11/08/2005 12:00:00 1.2 0.6 2.6 0.4 1.1 0.6 2.3 0.4 1.2 0.6 2.6 0.4 232 19 216 300 -9.6 0 -9.3 -9.7 11/08/2005 12:10:00 1.2 0.6 2.3 0.4 1.1 0.6 2.3 0.4 1.2 0.4 2.3 0.4 192 29 241 300 -9.6 0 -9.3 -9.7 11/08/2005 12:20:00 1 0.5 2.3 0.4 0.9 0.4 2.3 0.4 1 0.4 2.3 0.4 207 20 223 300 -9.4 0 -9.3 -9.5 11/08/2005 12:30:00 1.5 0.8 2.6 0.4 1.3 0.7 2.6 0.4 1.3 0.7 2.6 0.4 182 15 171 300 -9.3 0 -9.3 -9.3 11/08/2005 12:40:00 1.7 0.5 3 0.4 1.5 0.6 3 0.4 1.4 0.5 2.6 0.4 178 10 181 300 -9.3 0 -9.1 -9.3 11/08/2005 12:50:00 1.3 0.5 3 0.4 1.2 0.6 2.6 0.4 1.1 0.5 2.3 0.4 168 21 176 300 -9.1 0 -8.9 -9.3 11/08/2005 13:00:00 1.6 0.5 3 0.4 1.4 0.5 2.6 0.4 1.4 0.5 2.6 0.4 164 17 178 300 -9.2 0 -8.9 -9.3 11/08/2005 13:10:00 1.4 0.5 2.6 0.4 1.2 0.5 2.3 0.4 1.3 0.5 2.6 0.4 167 18 150 300 -9 0 -8.9 -9.1 11/08/2005 13:20:00 1 0.5 2.3 0.4 0.9 0.5 2.3 0.4 1 0.5 2.3 0.4 170 26 150 300 -8.8 0 -8.7 -8.9 11/08/2005 13:30:00 0.8 0.5 2.6 0.4 0.7 0.5 2.6 0.4 0.8 0.4 2.3 0.4 142 23 143 300 -8.5 0.2 -8.1 -8.9 11/08/2005 13:40:00 0.6 0.4 1.9 0.4 0.5 0.3 1.5 0.4 0.5 0.3 1.9 0.4 152 58 111 300 -8.2 0 -8.1 -8.3 11/08/2005 13:50:00 0.7 0.4 1.9 0.4 0.7 0.4 2.3 0.4 0.8 0.4 1.5 0.4 155 76 204 300 -8.2 0 -8.1 -8.5 11/08/2005 14:00:00 1.2 0.5 2.3 0.4 1 0.5 2.3 0.4 1.3 0.5 2.3 0.4 192 15 170 300 -8.4 0 -8.1 -8.5 11/08/2005 14:10:00 1.1 0.5 1.9 0.4 0.9 0.4 1.9 0.4 1 0.4 1.9 0.4 169 17 138 300 -8 0.1 -7.9 -8.3 11/08/2005 14:20:00 1.6 0.5 2.6 0.4 1.4 0.5 2.6 0.4 1.5 0.5 2.6 0.4 154 12 167 300 -8.1 0.2 -7.6 -8.5 11/08/2005 14:30:00 1.5 0.4 2.6 0.7 1.2 0.5 2.3 0.4 1.3 0.4 2.3 0.4 155 18 174 300 -8.5 0 -8.5 -8.7 11/08/2005 14:40:00 2 0.4 3 1.1 1.9 0.4 2.6 0.7 1.9 0.5 3 0.7 108 26 96 300 -8.5 0.2 -8.1 -8.9 11/08/2005 14:50:00 1.6 0.5 2.6 0.4 1.4 0.5 2.6 0.4 1.5 0.5 2.6 0.4 109 9 106 300 -9.1 0.1 -8.9 -9.3 11/08/2005 15:00:00 1.5 0.4 2.3 0.4 1.3 0.4 2.3 0.4 1.4 0.4 2.3 0.4 104 11 107 300 -9.2 0 -9.1 -9.3 11/08/2005 15:10:00 1.2 0.4 2.3 0.4 0.9 0.4 1.9 0.4 1 0.4 1.9 0.4 109 12 104 300 -9.4 0 -9.3 -9.7 11/08/2005 15:20:00 0.9 0.4 1.9 0.4 0.7 0.4 1.9 0.4 0.9 0.4 1.9 0.4 96 5 90 300 -9.6 0 -9.5 -9.7 11/08/2005 15:30:00 1.4 0.4 2.3 0.4 1.1 0.4 2.3 0.4 1.2 0.4 2.3 0.4 79 7 75 300 -9.7 0 -9.7 -9.7 11/08/2005 15:40:00 1.4 0.3 1.9 0.4 1 0.4 1.9 0.4 1.2 0.3 1.9 0.4 81 6 86 300 -9.8 0 -9.7 -9.7 11/08/2005 15:50:00 1.7 0.4 2.6 0.7 1.4 0.4 2.3 0.4 1.7 0.4 2.6 0.7 86 10 99 300 -9.8 0 -9.7 -10 11/08/2005 16:00:00 1.7 0.4 2.6 0.7 1.4 0.5 2.3 0.4 1.6 0.5 2.6 0.4 98 8 106 300 -9.9 0 -9.7 -10 11/08/2005 16:10:00 2 0.4 2.6 0.7 1.8 0.4 2.6 0.4 1.8 0.4 2.6 0.7 92 9 120 300 -10 0 -9.7 -10.2 11/08/2005 16:20:00 1.9 0.4 2.6 1.1 1.7 0.4 2.6 0.7 1.6 0.5 2.6 0.4 77 10 75 300 -10.1 0 -10 -10.2 11/08/2005 16:30:00 1.9 0.4 2.6 0.7 1.7 0.5 3 0.4 1.7 0.5 3 0.7 68 10 57 300 -10.2 0 -10.2 -10.2 11/08/2005 16:40:00 1.7 0.3 2.6 0.7 1.5 0.4 2.3 0.7 1.5 0.4 2.6 0.4 67 10 72 300 -10.3 0 -10.2 -10.4 11/08/2005 16:50:00 1.4 0.5 2.3 0.4 1.1 0.5 2.3 0.4 1 0.5 2.3 0.4 62 13 66 300 -10.4 0 -10.4 -10.4 11/08/2005 17:00:00 1.8 0.4 2.6 0.4 1.6 0.4 2.3 0.4 1.5 0.5 2.3 0.4 69 13 83 300 -10.4 0 -10.2 -10.6 11/08/2005 17:10:00 1.8 0.3 2.6 1.1 1.6 0.3 2.3 0.7 1.4 0.4 2.3 0.4 66 12 59 300 -10.4 0 -10.4 -10.6 11/08/2005 17:20:00 1.7 0.4 2.3 0.4 1.4 0.4 2.3 0.4 1.4 0.5 2.6 0.4 54 14 53 300 -10.5 0 -10.4 -10.6 11/08/2005 17:30:00 2 0.3 2.6 1.1 1.8 0.4 2.6 1.1 1.7 0.4 2.6 0.7 50 8 51 300 -10.6 0 -10.6 -10.8 11/08/2005 17:40:00 1.9 0.3 2.6 0.7 1.6 0.4 2.6 0.4 1.5 0.4 2.6 0.4 56 10 64 300 -10.7 0 -10.6 -11 11/08/2005 17:50:00 2.1 0.3 3 1.5 1.9 0.4 3 1.1 1.8 0.3 2.6 1.1 51 10 39 300 -10.8 0 -10.6 -11 11/08/2005 18:00:00 2.4 0.4 3.4 1.5 2.3 0.4 3 1.1 2.1 0.4 3 1.1 59 13 67 300 -10.9 0 -10.8 -11 11/08/2005 18:10:00 1.9 0.5 3 0.4 1.6 0.6 3 0.4 1.7 0.5 2.6 0.7 58 15 36 300 -10.9 0 -10.8 -11 11/08/2005 18:20:00 2.2 0.3 3 1.5 2.1 0.4 3 0.7 2 0.4 3 0.7 56 9 49 300 -11.1 0 -11 -11.2 11/08/2005 18:30:00 2.1 0.4 3 1.1 1.9 0.4 3 1.1 1.7 0.5 2.6 0.7 52 9 67 300 -11.3 0.1 -11 -11.4 11/08/2005 18:40:00 1.6 0.4 2.3 0.7 1.4 0.5 2.3 0.4 1.1 0.4 1.9 0.4 49 8 47 300 -11.5 0 -11.4 -11.6 11/08/2005 18:50:00 1.7 0.5 2.6 0.7 1.4 0.6 2.6 0.4 1.3 0.4 2.3 0.4 51 4 51 300 -11.6 0 -11.4 -11.8 11/08/2005 19:00:00 2.4 0.2 3.4 1.9 2.3 0.3 3 1.5 1.9 0.3 2.6 1.1 46 9 31 300 -11.8 0 -11.8 -12 11/08/2005 19:10:00 2.7 0.3 3.4 1.9 2.6 0.3 3.4 1.9 2.1 0.3 3 1.1 46 7 40 300 -11.8 0 -11.6 -11.8 11/08/2005 19:20:00 2.9 0.3 3.4 2.3 2.9 0.3 3.4 1.9 2.3 0.3 3 1.5 48 6 52 300 -11.8 0 -11.8 -11.8 11/08/2005 19:30:00 2.8 0.3 3.8 1.9 2.8 0.4 3.8 1.9 2.2 0.5 3.4 1.1 46 6 53 300 -11.6 0 -11.4 -11.8 11/08/2005 19:40:00 3.2 0.4 4.2 2.3 3.2 0.4 4.2 2.3 2.6 0.4 3.8 1.9 66 6 74 300 -11.6 0 -11.4 -11.6 11/08/2005 19:50:00 2.7 0.7 4.6 1.5 2.7 0.7 4.6 1.1 2.1 0.6 3.8 1.1 60 13 83 300 -11.5 0 -11.4 -11.6 11/08/2005 20:00:00 2.4 0.4 3 1.5 2.3 0.4 3 1.1 1.9 0.4 2.6 1.1 61 12 67 300 -11.5 0 -11.4 -11.4 11/08/2005 20:10:00 2.1 0.3 2.6 1.5 1.9 0.3 2.6 1.5 1.5 0.3 2.3 0.7 48 8 43 300 -11.3 0 -11 -11.4 11/08/2005 20:20:00 1.7 0.3 2.6 1.1 1.5 0.4 2.3 0.4 1.1 0.4 2.3 0.4 48 17 38 300 -11 0 -11 -11.2 11/08/2005 20:30:00 1.8 0.2 2.3 1.1 1.6 0.3 2.3 0.7 1.5 0.3 2.3 0.7 45 7 35 300 -10.9 0 -10.8 -11 11/08/2005 20:40:00 1.9 0.3 2.6 1.1 1.7 0.4 2.6 0.7 1.4 0.5 2.3 0.4 61 9 59 300 -10.8 0 -10.6 -11 11/08/2005 20:50:00 2 0.4 3 1.1 1.9 0.4 3 0.7 1.6 0.4 2.3 0.4 63 14 79 300 -10.7 0 -10.6 -10.8 11/08/2005 21:00:00 1.8 0.4 2.6 1.1 1.6 0.4 2.6 0.7 1.3 0.3 1.9 0.7 64 14 75 300 -10.5 0 -10.4 -10.6 11/08/2005 21:10:00 2.1 0.4 3 1.1 1.9 0.4 3 0.7 1.8 0.4 2.6 0.7 53 9 57 300 -10.4 0 -10.4 -10.6 11/08/2005 21:20:00 2.1 0.3 3 1.1 2 0.4 3 1.1 1.7 0.4 2.6 0.4 54 15 53 300 -10.3 0 -10.2 -10.4 11/08/2005 21:30:00 2.2 0.2 3 1.5 2 0.3 2.6 1.5 1.7 0.4 2.3 0.7 45 16 25 300 -10.1 0 -10 -10.4 11/08/2005 21:40:00 1.7 0.3 2.6 1.1 1.6 0.4 2.6 0.7 1.3 0.4 2.3 0.4 64 7 73 300 -10 0 -9.7 -10.2 11/08/2005 21:50:00 1.7 0.3 2.6 0.4 1.4 0.4 2.3 0.4 1.3 0.4 2.3 0.4 53 12 46 300 -9.8 0 -9.7 -10 11/08/2005 22:00:00 1.7 0.3 2.3 0.7 1.6 0.3 2.3 0.4 1.4 0.3 2.3 0.4 65 10 69 300 -9.8 0 -9.7 -10.4 11/08/2005 22:10:00 1.6 0.4 2.6 0.7 1.4 0.5 2.6 0.4 1.4 0.4 2.3 0.4 66 11 67 300 -9.7 0 -9.5 -9.7 11/08/2005 22:20:00 0.7 0.4 1.9 0.4 0.5 0.3 1.5 0.4 0.6 0.3 1.5 0.4 61 19 58 300 -9.5 0 -9.3 -9.7 11/08/2005 22:30:00 0.4 0.1 1.5 0.4 0.4 0.1 1.1 0.4 0.4 0.1 1.1 0.4 60 19 138 300 -9.3 0 -9.3 -9.3 11/08/2005 22:40:00 0.6 0.3 1.5 0.4 0.4 0.2 1.1 0.4 0.5 0.2 1.5 0.4 123 9 138 300 -9.3 0 -9.3 -9.3 11/08/2005 22:50:00 0.4 0.1 0.7 0.4 0.4 0 0.7 0.4 0.4 0.1 1.1 0.4 108 4 107 300 -9.3 0 -9.3 -9.3 11/08/2005 23:00:00 0.4 0.2 1.1 0.4 0.4 0.1 0.7 0.4 0.4 0.1 1.1 0.4 98 8 102 300 -9.5 0 -9.3 -9.7 11/08/2005 23:10:00 0.4 0.1 0.7 0.4 0.4 0 0.4 0.4 0.4 0 0.7 0.4 82 0 82 300 -9.6 0 -9.5 -9.7 11/08/2005 23:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 82 0 300 300 -9.8 0 -9.7 -10 11/08/2005 23:30:00 0.6 0.3 1.5 0.4 0.4 0.2 1.1 0.4 0.5 0.2 1.1 0.4 120 16 138 300 -10 0 -9.7 -10.2 11/08/2005 23:40:00 0.4 0.1 0.7 0.4 0.4 0 0.7 0.4 0.4 0.1 0.7 0.4 137 0 138 300 -10.1 0 -10 -10.2 11/08/2005 23:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 137 0 300 300 -10.1 0 -10 -10.2 11/09/2005 00:00:00 0.4 0 0.7 0.4 0.4 0 0.4 0.4 0.4 0.1 0.7 0.4 137 0 137 300 -10.1 0 -10 -10.2 11/09/2005 00:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 137 0 300 300 -10.1 0 -10 -10.2 11/09/2005 00:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 137 0 300 300 -10.3 0 -10.2 -10.4 11/09/2005 00:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 137 0 300 300 -10.4 0 -10.4 -10.6 11/09/2005 00:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 137 0 300 300 -10.6 0 -10.4 -10.8 11/09/2005 00:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0.2 1.1 0.4 136 5 300 300 -10.8 0.1 -10.6 -11 11/09/2005 01:00:00 0.5 0.3 1.1 0.4 0.4 0.2 1.1 0.4 0.7 0.2 1.1 0.4 105 1 105 300 -11 0 -11 -11.4 11/09/2005 01:10:00 0.8 0.3 1.5 0.4 0.5 0.2 1.1 0.4 0.6 0.3 1.1 0.4 107 0 107 300 -11.3 0 -11.2 -11.4 11/09/2005 01:20:00 0.9 0.3 1.5 0.4 0.6 0.3 1.5 0.4 0.7 0.3 1.5 0.4 95 14 83 300 -11.5 0 -11.4 -11.8 11/09/2005 01:30:00 1.2 0.3 1.9 0.4 0.9 0.3 1.5 0.4 1.3 0.2 1.9 0.7 62 8 75 300 -11.6 0 -11.4 -11.8 11/09/2005 01:40:00 1.4 0.3 1.9 0.4 1.1 0.3 1.5 0.4 1.3 0.4 2.3 0.7 95 4 98 300 -11.6 0 -11.6 -11.8 11/09/2005 01:50:00 1.7 0.2 2.3 1.5 1.5 0.2 2.3 1.1 1.8 0.3 2.3 1.1 87 13 66 300 -11.8 0.1 -11.4 -12 11/09/2005 02:00:00 2.4 0.3 3 1.9 2.3 0.3 3 1.5 2.4 0.2 2.6 1.9 73 11 74 300 -12 0.1 -11.6 -12.2 11/09/2005 02:10:00 2.5 0.4 3 1.5 2.4 0.4 3 1.5 1.9 0.5 3 0.7 72 6 66 300 -11.6 0 -11.4 -11.8 11/09/2005 02:20:00 2.5 0.3 3 1.9 2.4 0.3 3 1.9 2 0.3 2.6 1.1 70 5 72 300 -11.8 0.1 -11.6 -11.8 11/09/2005 02:30:00 2.5 0.3 3 1.9 2.4 0.4 3 1.5 2.3 0.3 3 1.5 56 4 59 300 -11.6 0.1 -11.2 -11.8 11/09/2005 02:40:00 1.9 0.4 2.6 0.7 1.6 0.5 2.6 0.4 2.2 0.3 2.6 1.5 67 17 48 300 -11 0 -11 -11.4 11/09/2005 02:50:00 2.2 0.4 3 1.1 2.1 0.5 3 0.7 2.1 0.2 2.6 1.5 91 8 84 300 -11.2 0.1 -11 -11.6 11/09/2005 03:00:00 2.3 0.4 3 1.5 2.2 0.4 3 1.1 2.4 0.4 3 1.5 71 9 66 300 -11.5 0.1 -11.2 -11.8 11/09/2005 03:10:00 2.2 0.4 3 1.1 2.1 0.5 3 0.7 2 0.7 3 0.4 73 4 74 300 -11 0 -11 -11.2 11/09/2005 03:20:00 2 0.4 2.6 1.1 1.9 0.5 2.6 0.7 1.6 0.4 2.6 0.7 64 9 67 300 -11.2 0.1 -11 -11.4 11/09/2005 03:30:00 2 0.3 2.6 1.5 1.8 0.3 2.3 0.7 1.7 0.3 2.3 0.4 95 13 103 300 -11.5 0 -11.4 -11.6 11/09/2005 03:40:00 1.3 0.2 1.9 0.7 0.9 0.2 1.5 0.4 1 0.2 1.5 0.4 101 3 102 300 -11.5 0 -11.4 -11.8 11/09/2005 03:50:00 1.7 0.2 2.3 0.7 1.5 0.3 2.3 0.7 1.5 0.2 1.9 1.1 86 10 85 300 -11.5 0 -11.4 -11.6 11/09/2005 04:00:00 2.1 0.3 2.6 1.5 2 0.4 2.6 1.1 1.9 0.4 2.6 1.1 68 10 59 300 -11.6 0 -11.4 -12.2 11/09/2005 04:10:00 2.1 0.2 2.6 1.9 2 0.2 2.6 1.5 2.2 0.2 2.6 1.5 71 14 69 300 -11.4 0.2 -11 -11.8 11/09/2005 04:20:00 1.7 0.4 2.3 0.4 1.5 0.4 2.3 0.4 1.6 0.4 2.6 0.4 81 19 82 300 -10.9 0 -10.8 -11 11/09/2005 04:30:00 0.8 0.4 1.9 0.4 0.6 0.3 1.5 0.4 0.9 0.4 1.9 0.4 101 22 94 300 -10.8 0 -10.6 -11 11/09/2005 04:40:00 1.7 0.5 2.6 1.1 1.4 0.5 2.6 0.7 1.8 0.5 2.6 0.7 93 8 83 300 -10.8 0 -10.6 -11 11/09/2005 04:50:00 1.8 0.5 3 1.1 1.6 0.6 2.6 0.7 1.9 0.5 3 1.1 86 16 65 300 -10.9 0 -10.8 -11 11/09/2005 05:00:00 1.5 0.3 2.3 0.4 1.2 0.3 1.9 0.4 1.3 0.3 1.9 0.4 107 12 124 300 -10.9 0 -10.8 -11 11/09/2005 05:10:00 2.7 0.6 3.8 1.5 2.7 0.6 3.8 1.1 2.5 0.5 3.4 1.5 71 16 69 300 -11.1 0 -11 -11.4 11/09/2005 05:20:00 2.6 0.5 3.4 1.5 2.5 0.6 3.4 1.1 2.3 0.4 3.4 1.1 56 11 63 300 -10.8 0.1 -10.6 -11 11/09/2005 05:30:00 2.1 0.3 3 1.5 1.9 0.4 2.6 1.1 2 0.3 2.6 0.7 81 17 77 300 -10.6 0 -10.6 -10.8 11/09/2005 05:40:00 2 0.5 3.4 0.7 1.8 0.6 3.4 0.7 2.2 0.4 3 1.1 91 18 54 300 -10.8 0.1 -10.6 -11 11/09/2005 05:50:00 2 0.4 2.6 1.1 1.9 0.4 2.6 0.7 1.9 0.6 3 0.4 96 22 69 300 -10.7 0 -10.6 -11 11/09/2005 06:00:00 0.8 0.4 1.9 0.4 0.6 0.3 1.5 0.4 0.4 0.1 0.7 0.4 101 11 99 300 -10.6 0 -10.4 -10.8 11/09/2005 06:10:00 0.7 0.4 1.5 0.4 0.5 0.3 1.5 0.4 0.4 0.1 0.7 0.4 95 7 98 300 -10.2 0.1 -10.2 -10.6 11/09/2005 06:20:00 1 0.4 1.9 0.4 0.8 0.3 1.5 0.4 0.4 0.1 1.1 0.4 100 12 111 300 -10 0 -9.7 -10.2 11/09/2005 06:30:00 1 0.6 2.3 0.4 0.8 0.5 2.3 0.4 0.6 0.3 1.5 0.4 96 24 124 300 -9.9 0 -9.7 -10 11/09/2005 06:40:00 1 0.4 1.9 0.4 0.7 0.4 1.5 0.4 0.5 0.2 1.5 0.4 108 28 35 300 -9.7 0 -9.5 -9.7 11/09/2005 06:50:00 1.1 0.5 2.3 0.4 0.9 0.5 1.9 0.4 0.5 0.3 1.5 0.4 132 15 132 300 -9.4 0 -9.3 -9.7 11/09/2005 07:00:00 1.3 0.6 3.4 0.4 1 0.5 3 0.4 0.7 0.5 2.6 0.4 134 28 75 300 -9.1 0.1 -8.9 -9.3 11/09/2005 07:10:00 1.6 0.5 2.6 0.4 1.3 0.5 2.6 0.4 1 0.5 2.3 0.4 123 18 146 300 -9.2 0 -8.9 -9.3 11/09/2005 07:20:00 1.3 0.6 2.3 0.4 1.1 0.5 2.3 0.4 0.8 0.5 2.3 0.4 79 27 88 300 -9.1 0.1 -8.9 -9.3 11/09/2005 07:30:00 1.7 0.4 2.6 0.7 1.5 0.5 2.6 0.4 1.2 0.4 1.9 0.4 73 15 87 300 -9 0 -8.9 -8.9 11/09/2005 07:40:00 1.4 0.5 2.6 0.4 1.2 0.5 2.6 0.4 0.9 0.5 2.3 0.4 94 21 89 300 -8.8 0 -8.7 -8.9 11/09/2005 07:50:00 0.9 0.5 2.3 0.4 0.8 0.5 1.9 0.4 0.6 0.3 1.5 0.4 98 13 103 300 -8.7 0 -8.5 -8.7 11/09/2005 08:00:00 1.2 0.5 2.3 0.4 0.9 0.5 2.3 0.4 0.6 0.3 1.5 0.4 128 7 131 300 -8.7 0 -8.5 -8.7 11/09/2005 08:10:00 1.1 0.4 1.9 0.4 0.9 0.4 1.9 0.4 0.6 0.4 1.9 0.4 132 12 123 300 -8.6 0 -8.5 -8.7 11/09/2005 08:20:00 1.3 0.5 2.3 0.4 1 0.5 2.3 0.4 0.7 0.4 1.9 0.4 132 9 133 300 -8.5 0 -8.5 -8.5 11/09/2005 08:30:00 0.8 0.5 1.9 0.4 0.6 0.4 1.5 0.4 0.5 0.3 1.5 0.4 135 6 141 300 -8.4 0 -8.3 -8.5 11/09/2005 08:40:00 1.1 0.5 2.3 0.4 0.8 0.4 2.3 0.4 0.7 0.3 1.5 0.4 157 10 137 300 -8.5 0 -8.5 -8.5 11/09/2005 08:50:00 0.4 0.1 0.7 0.4 0.4 0 0.4 0.4 0.4 0.1 0.7 0.4 181 7 169 300 -8.5 0 -8.5 -8.5 11/09/2005 09:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 186 0 300 300 -8.5 0 -8.3 -8.5 11/09/2005 09:10:00 0.4 0.2 1.5 0.4 0.4 0.1 1.1 0.4 0.4 0.1 0.7 0.4 132 58 104 300 -8.2 0 -8.1 -8.5 11/09/2005 09:20:00 0.7 0.4 1.5 0.4 0.6 0.3 1.5 0.4 0.4 0 0.4 0.4 128 12 105 300 -8.1 0 -7.9 -8.1 11/09/2005 09:30:00 0.9 0.4 1.9 0.4 0.7 0.4 1.9 0.4 0.4 0.1 1.1 0.4 131 15 135 300 -7.9 0 -7.6 -8.1 11/09/2005 09:40:00 0.9 0.6 1.9 0.4 0.7 0.5 1.9 0.4 0.4 0.1 0.7 0.4 118 13 132 300 -7.6 0 -7.4 -7.9 11/09/2005 09:50:00 0.9 0.6 1.9 0.4 0.8 0.5 1.9 0.4 0.5 0.2 1.1 0.4 133 9 144 300 -7.2 0.1 -7 -7.6 11/09/2005 10:00:00 1 0.5 1.9 0.4 0.9 0.4 1.9 0.4 0.8 0.4 1.9 0.4 177 15 149 300 -7.1 0 -7 -7.2 11/09/2005 10:10:00 1.3 0.5 2.6 0.4 1.1 0.5 2.3 0.4 1.1 0.5 2.3 0.4 183 8 187 300 -6.9 0.1 -6.8 -7 11/09/2005 10:20:00 1.6 0.7 3 0.4 1.5 0.7 3 0.4 1.5 0.6 2.6 0.4 184 15 177 300 -7 0 -6.8 -7 11/09/2005 10:30:00 1 0.5 2.6 0.4 0.8 0.5 2.3 0.4 1.1 0.5 2.3 0.4 171 15 167 300 -6.6 0 -6.6 -6.8 11/09/2005 10:40:00 1.7 0.4 2.6 0.4 1.5 0.4 2.6 0.4 1.7 0.3 2.3 0.4 174 13 186 300 -6.5 0.1 -6.1 -6.8 11/09/2005 10:50:00 1.8 0.6 3 0.4 1.7 0.6 2.6 0.4 1.7 0.5 2.6 0.4 181 13 179 300 -6.2 0 -6.1 -6.4 11/09/2005 11:00:00 1.1 0.4 1.9 0.4 0.8 0.4 1.9 0.4 1.1 0.5 2.3 0.4 170 23 182 300 -6 0 -5.7 -6.1 11/09/2005 11:10:00 1.5 0.6 3 0.4 1.3 0.6 3 0.4 1.6 0.5 2.6 0.4 161 27 187 300 -5.6 0.2 -5.3 -5.9 11/09/2005 11:20:00 1.4 0.7 3 0.4 1.2 0.7 3 0.4 1.3 0.5 2.3 0.4 142 33 150 300 -5.2 0 -4.8 -5.3 11/09/2005 11:30:00 1.4 0.5 2.3 0.4 1.2 0.5 2.3 0.4 1.3 0.4 2.3 0.4 171 10 164 300 -4.5 0.3 -4.2 -5 11/09/2005 11:40:00 1.1 0.6 2.6 0.4 0.9 0.6 2.6 0.4 0.9 0.4 2.6 0.4 126 29 118 300 -4 0 -3.9 -4.2 11/09/2005 11:50:00 2.3 0.5 3.8 1.1 2.2 0.6 3.8 0.7 1.9 0.4 3.4 0.7 94 23 89 300 -3.8 0 -3.7 -3.9 11/09/2005 12:00:00 2.3 0.7 4.2 0.7 2.2 0.8 4.2 0.4 2.1 0.8 4.6 0.4 102 23 74 300 -3.8 0 -3.7 -3.9 11/09/2005 12:10:00 2.3 0.5 4.2 1.1 2.2 0.6 4.2 0.7 1.9 0.6 3 0.4 110 18 66 300 -3.8 0 -3.5 -3.9 11/09/2005 12:20:00 2.3 0.6 4.9 1.1 2.3 0.7 4.6 1.1 2 0.8 4.2 0.4 104 22 85 300 -3.5 0 -3.3 -3.7 11/09/2005 12:30:00 1.8 0.7 3.4 0.4 1.6 0.7 3 0.4 1.4 0.7 3 0.4 105 27 100 300 -3.4 0.1 -3.3 -3.7 11/09/2005 12:40:00 1.9 0.4 3 1.1 1.8 0.5 3 0.7 1.6 0.4 2.6 0.4 121 19 115 300 -3.9 0 -3.5 -4.2 11/09/2005 12:50:00 1.5 0.4 2.6 0.4 1.3 0.5 2.3 0.4 1.5 0.4 2.3 0.7 138 13 140 300 -4.2 0 -3.9 -4.4 11/09/2005 13:00:00 2.2 0.3 3 1.1 2 0.3 2.6 1.1 1.9 0.5 3 0.4 139 9 137 300 -4.1 0 -3.9 -4.4 11/09/2005 13:10:00 1.3 0.4 2.6 0.4 1 0.5 2.3 0.4 1 0.5 1.9 0.4 113 19 71 300 -4.1 0 -3.9 -4.4 11/09/2005 13:20:00 1.4 0.5 2.3 0.4 1.2 0.5 2.3 0.4 1.2 0.5 1.9 0.4 116 23 134 300 -4 0 -3.9 -4.2 11/09/2005 13:30:00 1.5 1.2 6.5 0.4 1.4 1.2 6.8 0.4 1.1 0.8 4.6 0.4 93 26 59 300 -3.8 0 -3.5 -3.9 11/09/2005 13:40:00 2.4 0.9 5.7 1.1 2.3 1 5.7 0.4 2 0.7 4.2 0.4 96 28 88 300 -3.5 0 -3.5 -3.5 11/09/2005 13:50:00 3.1 0.9 6.1 0.7 3.1 1 6.1 1.1 2.7 0.7 4.6 1.1 90 20 58 300 -3.5 0 -3.3 -3.5 11/09/2005 14:00:00 3 0.7 6.5 1.5 2.9 0.7 6.5 1.5 2.3 0.8 5.7 0.4 96 19 88 300 -3.7 0 -3.5 -3.7 11/09/2005 14:10:00 3 1 7.2 0.7 2.8 1.1 6.8 0.4 2.2 1.1 6.5 0.7 92 19 83 300 -3.4 0 -3.3 -3.5 11/09/2005 14:20:00 2.8 0.7 4.6 1.5 2.7 0.7 4.6 1.1 1.9 0.6 3.4 0.7 96 15 87 300 -3.4 0 -3.3 -3.5 11/09/2005 14:30:00 3.7 0.9 6.1 1.1 3.7 0.9 6.1 1.5 2.9 0.7 4.9 1.1 73 14 57 300 -2.9 0.1 -2.6 -3.3 11/09/2005 14:40:00 3.8 1 6.5 1.1 3.7 1 6.5 1.1 3 0.9 5.7 1.1 62 15 52 300 -2.5 0.1 -2.4 -2.6 11/09/2005 14:50:00 3.3 0.8 5.7 1.5 3.3 0.7 5.3 1.5 2.7 0.7 4.6 0.7 79 21 79 300 -2.5 0 -2.4 -2.8 11/09/2005 15:00:00 2.7 0.6 4.2 1.1 2.7 0.6 4.6 0.7 2.1 0.6 4.2 0.7 100 15 88 300 -3.1 0.2 -2.6 -3.5 11/09/2005 15:10:00 2 0.6 3.4 0.4 1.8 0.6 3.4 0.4 1.4 0.5 2.6 0.4 98 17 100 300 -3.6 0.1 -3.5 -3.7 11/09/2005 15:20:00 2.1 0.8 5.7 0.4 2 0.9 5.7 0.4 1.5 0.6 3.4 0.4 100 21 71 300 -3.7 0 -3.5 -3.7 11/09/2005 15:30:00 2.5 0.8 4.9 0.7 2.4 0.8 4.6 0.4 1.7 0.5 3 0.4 101 23 121 300 -3.7 0 -3.5 -3.7 11/09/2005 15:40:00 2.7 0.7 4.9 1.5 2.6 0.8 4.6 0.7 2.1 0.7 3.8 0.4 61 17 92 300 -3.3 0.3 -2.6 -3.7 11/09/2005 15:50:00 2.5 1 5.7 0.7 2.4 1.1 5.7 1.1 2.2 0.8 4.6 0.7 85 22 69 300 -2.9 0.2 -2.6 -3.3 11/09/2005 16:00:00 3.2 0.6 4.9 1.9 3.2 0.6 4.9 1.9 2.6 0.6 4.2 1.1 84 13 77 300 -3.5 0.1 -3.3 -3.7 11/09/2005 16:10:00 3.8 0.9 6.5 0.7 3.7 0.9 6.5 0.4 2.6 0.7 5.7 0.7 55 16 40 300 -3.5 0.1 -3 -3.5 11/09/2005 16:20:00 5.8 1.5 10.7 1.9 5.7 1.6 11.8 2.6 4.7 1.2 8.4 1.5 49 17 78 300 -2.1 0.4 -1.4 -3 11/09/2005 16:30:00 5.2 1.5 9.9 1.9 5.1 1.5 9.9 1.5 4.2 1.5 9.1 0.7 52 17 46 300 -1.4 0 -1.2 -1.4 11/09/2005 16:40:00 5 1.6 9.5 1.1 4.9 1.6 9.5 1.1 4.2 1.3 8.4 1.5 52 20 43 300 -1.6 0.2 -1.2 -2.1 11/09/2005 16:50:00 6 1.7 9.9 0.4 5.9 1.8 10.3 0.4 4.3 1.7 8.8 1.1 49 19 65 300 -1.1 0 -1 -1.4 11/09/2005 17:00:00 5 1.7 9.1 1.1 4.8 1.8 9.5 0.7 3.6 1.5 8 1.1 48 22 53 300 -1 0 -0.7 -1.2 11/09/2005 17:10:00 5.9 1.4 9.5 1.9 5.8 1.5 9.5 2.3 4.7 1.3 8 1.9 52 17 37 300 -0.9 0 -0.7 -1 11/09/2005 17:20:00 5.1 1.5 8.8 1.9 5 1.4 8.4 1.5 3.9 1.3 7.2 0.4 51 19 26 300 -0.9 0 -0.7 -1 11/09/2005 17:30:00 5.6 1.7 9.9 1.9 5.6 1.7 9.9 0.7 4.5 1.6 10.3 1.1 54 22 43 300 -1.2 0.1 -1 -1.4 11/09/2005 17:40:00 7.1 2 11.5 3 7 2.1 11.8 3 5.6 2 10.7 2.3 47 17 37 300 -1.3 0.2 -0.7 -1.4 11/09/2005 17:50:00 7.2 1.7 11.8 2.3 7.1 1.9 11.5 2.3 5.7 1.7 10.3 1.9 50 17 37 300 -0.8 0 -0.7 -0.7 11/09/2005 18:00:00 7.8 2.4 13 2.6 7.6 2.5 13 1.9 6.2 2.4 12.2 1.9 49 22 60 300 -0.7 0 -0.5 -0.7 11/09/2005 18:10:00 7 1.8 10.7 1.1 7 1.9 11.1 2.3 5.4 1.7 9.5 1.9 50 18 49 300 -0.7 0 -0.5 -0.7 11/09/2005 18:20:00 7.8 1.9 13 3.4 7.7 2 13.3 3.4 5.9 1.8 11.1 1.9 53 16 39 300 -0.5 0 -0.5 -0.5 11/09/2005 18:30:00 7.2 2 12.2 2.3 7.1 2.1 12.2 2.6 5.6 2 11.8 1.5 49 17 39 300 -0.3 0 -0.1 -0.5 11/09/2005 18:40:00 6.3 1.5 10.7 1.5 6.3 1.6 11.1 1.1 4.8 1.5 9.9 2.3 54 22 50 300 -0.5 0 -0.3 -0.5 11/09/2005 18:50:00 5.9 1.5 10.7 2.6 5.9 1.5 11.1 2.6 5 1.3 9.1 1.5 59 18 62 300 -0.7 0.2 -0.5 -1 11/09/2005 19:00:00 6 1.7 11.8 2.3 5.9 1.7 11.5 2.3 5 1.7 9.9 1.5 56 21 29 300 -0.7 0 -0.5 -1 11/09/2005 19:10:00 4.6 1.2 8 2.3 4.6 1.2 8 2.3 4 1 8.4 1.9 63 17 47 300 -1.5 0.3 -0.7 -2.1 11/09/2005 19:20:00 3.5 0.9 6.5 1.5 3.5 1 6.5 1.5 2.8 0.8 6.1 0.7 81 19 70 300 -2.9 0.5 -2.1 -3.7 11/09/2005 19:30:00 2.7 0.9 4.9 0.7 2.6 1 5.3 0.4 1.7 0.7 4.2 0.4 74 22 41 300 -3.8 0 -3.5 -3.9 11/09/2005 19:40:00 3.9 1.4 8.4 1.1 3.8 1.5 8 0.4 3.2 1 6.5 0.4 67 21 71 300 -3.1 0.3 -2.6 -3.7 11/09/2005 19:50:00 3.6 1.1 7.6 0.7 3.5 1.2 7.6 0.4 3 1 6.5 1.5 75 22 77 300 -2.7 0.2 -2.4 -3.3 11/09/2005 20:00:00 3.3 0.8 5.3 1.5 3.3 0.8 5.7 1.5 2.9 0.9 5.7 1.1 88 23 97 300 -3.5 0.1 -3.3 -3.7 11/09/2005 20:10:00 3.9 1.3 8.4 1.5 3.8 1.4 8.8 0.7 2.9 1.1 8 1.1 63 22 54 300 -3.2 0.6 -1.9 -3.7 11/09/2005 20:20:00 5.6 1.7 9.5 1.9 5.5 1.8 10.3 1.9 4.6 1.7 9.1 0.7 58 19 57 300 -1 0.5 -0.5 -2.1 11/09/2005 20:30:00 5.7 1.6 11.1 1.9 5.7 1.7 11.1 1.5 4.7 1.3 9.1 1.9 56 19 62 300 -0.3 0.1 -0.1 -0.5 11/09/2005 20:40:00 6.1 1.9 11.1 1.9 6 2 10.7 1.5 4.9 1.7 9.5 1.9 56 20 27 300 -0.2 0 -0.1 -0.5 11/09/2005 20:50:00 4.8 1.3 8.4 2.3 4.7 1.2 7.6 1.9 3.7 1 6.8 1.5 61 23 39 300 -1 0.4 -0.5 -1.4 11/09/2005 21:00:00 5.3 1.3 8.8 2.3 5.3 1.3 9.1 2.6 4.7 1.2 8.8 1.5 63 18 75 300 -1.9 0.1 -1.4 -2.1 11/09/2005 21:10:00 6.3 1.7 11.1 2.3 6.2 1.8 12.2 1.5 5.2 1.6 9.1 1.9 51 19 78 300 -0.7 0.4 -0.1 -1.7 11/09/2005 21:20:00 6.2 1.9 11.1 1.9 6.1 2 11.1 1.9 4.7 1.7 9.5 1.5 49 17 46 300 -0.2 0 -0.1 -0.3 11/09/2005 21:30:00 6.8 1.6 12.6 3.4 6.7 1.7 13 3 5.1 1.7 10.7 1.5 49 19 47 300 0 0 0.2 -0.1 11/09/2005 21:40:00 5.9 1.6 11.8 1.5 5.8 1.7 11.8 1.5 4.5 1.7 9.1 1.1 51 20 56 300 0.1 0 0.2 0.2 11/09/2005 21:50:00 6.4 1.9 12.6 2.6 6.2 2 12.6 2.3 5.1 1.9 12.6 1.1 49 20 35 300 0.3 0 0.7 0.2 11/09/2005 22:00:00 7.8 1.7 11.8 3.4 7.7 1.9 12.6 3 6 1.9 11.5 1.1 50 18 53 300 0.4 0 0.7 0.2 11/09/2005 22:10:00 7.5 2.1 12.6 1.5 7.4 2.3 13.3 1.1 5.8 1.9 11.5 1.5 50 23 40 300 0.2 0 0.4 0.2 11/09/2005 22:20:00 7 1.8 11.8 3 6.8 1.9 11.5 2.3 5.1 1.7 9.1 1.9 50 21 47 300 0.2 0.1 0.4 0.2 11/09/2005 22:30:00 6.7 2 11.1 1.1 6.6 2 11.1 1.5 5 1.8 9.5 1.1 50 20 53 300 0.2 0 0.4 0.2 11/09/2005 22:40:00 7 1.8 11.5 2.6 6.8 1.9 11.8 2.6 5.4 1.7 10.7 2.3 51 19 35 300 0.2 0 0.4 0.2 11/09/2005 22:50:00 6.5 2.2 11.5 1.1 6.4 2.2 11.8 1.1 5.6 2 11.1 1.9 53 20 46 300 0.3 0 0.4 0.2 11/09/2005 23:00:00 6.2 1.7 9.9 1.9 6.1 1.8 10.7 1.1 4.8 1.7 8.8 1.1 53 19 54 300 -0.1 0.1 0.2 -0.5 11/09/2005 23:10:00 6.8 1.6 11.1 3.8 6.8 1.7 11.8 2.3 5.2 1.6 10.3 2.3 48 15 40 300 0.2 0 0.4 0.2 11/09/2005 23:20:00 8.4 1.8 13.7 2.6 8.2 1.9 13.7 3 6.2 1.9 11.5 2.3 46 16 43 300 0.4 0 0.7 0.2 11/09/2005 23:30:00 9.2 1.7 13.3 4.9 9 1.8 13.3 4.2 7.2 2.1 14.5 2.6 44 14 32 300 0.4 0 0.4 0.2 11/09/2005 23:40:00 9.2 1.9 15.3 4.2 9.1 2 15.3 3.8 7.1 2.2 13 2.3 44 15 44 300 0.4 0 0.4 0.2 11/09/2005 23:50:00 8.2 1.9 13 3.8 8.1 2 13 3.8 6.2 1.8 11.8 2.3 45 15 36 300 0.4 0 0.7 0.2 11/10/2005 00:00:00 9.4 1.9 13.7 4.6 9.4 2.1 14.1 4.6 7.6 1.9 12.2 2.6 45 16 39 300 0.5 0 0.7 0.4 11/10/2005 00:10:00 8.8 1.7 13.7 4.6 8.6 1.9 14.1 4.9 7 2 13.7 1.9 43 15 56 300 0.5 0 0.7 0.4 11/10/2005 00:20:00 9 1.8 14.1 4.9 8.8 1.8 13.7 4.6 6.9 2 12.6 1.9 42 15 36 300 0.5 0 0.7 0.4 11/10/2005 00:30:00 9.5 1.8 14.1 4.6 9.3 1.9 13.3 4.2 7.6 1.9 12.6 3.4 41 13 34 300 0.6 0 0.7 0.4 11/10/2005 00:40:00 10.2 1.9 16.4 5.7 10.1 2 16.8 4.6 8.2 2.2 14.5 3.4 43 14 48 300 0.7 0 0.7 0.7 11/10/2005 00:50:00 9.5 1.6 13.3 4.9 9.3 1.7 13.3 4.2 7.4 1.7 11.8 3.8 43 12 40 300 0.5 0 0.7 0.4 11/10/2005 01:00:00 8.9 1.7 14.1 4.9 8.7 1.8 13.3 4.9 7 1.7 11.8 3 42 15 37 300 0.5 0 0.7 0.4 11/10/2005 01:10:00 10 2.1 14.5 5.3 9.9 2.2 14.5 4.2 7.8 2.2 13.3 1.9 42 15 62 300 0.6 0 0.7 0.7 11/10/2005 01:20:00 9.5 1.9 13.7 3.8 9.2 1.9 13.7 3 7.8 1.8 13.3 3.4 40 17 35 300 0.7 0 0.7 0.7 11/10/2005 01:30:00 9.5 2 14.5 5.3 9.3 2.1 15.3 3.8 7.6 2.2 13 2.6 41 15 39 300 0.7 0 0.7 0.7 11/10/2005 01:40:00 10 1.7 14.9 5.3 9.8 1.9 14.9 5.3 8.1 1.9 13.7 3.4 41 14 46 300 0.7 0 0.7 0.7 11/10/2005 01:50:00 8 2.3 13.7 3.4 7.8 2.4 14.1 2.3 6.3 2.2 13.3 2.3 44 15 37 300 0.7 0 0.7 0.4 11/10/2005 02:00:00 6.7 1.9 12.2 1.9 6.5 1.9 12.2 1.5 5 1.5 9.9 1.5 48 18 41 300 0.1 0 0.7 -0.1 11/10/2005 02:10:00 6.9 1.7 12.2 3.4 6.7 1.7 11.8 3.4 5.4 1.5 11.1 2.3 47 17 38 300 -0.1 0 0.2 -0.1 11/10/2005 02:20:00 7 1.8 11.5 2.3 6.9 1.9 11.5 2.3 5.3 1.8 11.1 1.9 48 17 43 300 -0.2 0 -0.1 -0.5 11/10/2005 02:30:00 6.2 1.6 11.5 2.6 6.1 1.6 11.5 2.3 4.8 1.5 10.7 2.3 53 17 38 300 -0.6 0.1 -0.1 -0.7 11/10/2005 02:40:00 5 1.7 10.3 1.5 5 1.7 10.7 1.1 3.8 1.5 9.1 1.5 56 17 46 300 -0.6 0.1 -0.3 -0.7 11/10/2005 02:50:00 4.3 1 6.8 2.3 4.3 1 7.2 2.3 3.5 0.9 6.5 1.5 67 16 63 300 -1 0.2 -0.7 -1.9 11/10/2005 03:00:00 4.2 0.6 6.5 3 4.1 0.6 6.5 2.6 3.5 0.6 5.3 1.1 76 12 64 300 -2.7 0.3 -1.7 -3.3 11/10/2005 03:10:00 4 0.6 5.7 2.6 4 0.7 5.7 2.3 3.4 0.7 4.9 1.9 89 8 87 300 -3.6 0.2 -3.3 -3.9 11/10/2005 03:20:00 3.4 0.6 4.6 1.5 3.2 0.7 4.9 1.5 2.6 0.6 3.8 1.1 90 13 88 300 -4.1 0.1 -3.7 -4.4 11/10/2005 03:30:00 2.8 0.5 4.2 1.5 2.7 0.6 4.6 1.5 2.3 0.5 3.4 1.1 91 11 87 300 -4.5 0 -3.7 -4.6 11/10/2005 03:40:00 3.3 0.5 4.9 2.3 3.3 0.5 5.3 2.3 2.5 0.4 3.8 1.1 80 10 83 300 -4.5 0 -4.2 -4.6 11/10/2005 03:50:00 2.2 0.6 3.8 0.7 2.1 0.6 4.2 0.7 1.5 0.7 3.4 0.4 81 12 99 300 -4.6 0 -3.9 -4.6 11/10/2005 04:00:00 1.2 0.4 2.3 0.4 1 0.5 1.9 0.4 0.7 0.4 1.9 0.4 88 16 51 300 -4.6 0 -4.4 -4.6 11/10/2005 04:10:00 2.3 0.4 3.4 1.5 2.1 0.5 3.4 1.1 1.9 0.4 2.6 0.7 97 12 97 300 -4.4 0 -4.4 -4.6 11/10/2005 04:20:00 2.2 0.4 3.4 1.1 2 0.4 3 1.1 1.9 0.4 2.6 0.4 112 12 96 300 -4.7 0.1 -4.4 -4.8 11/10/2005 04:30:00 1.9 0.3 2.6 1.1 1.7 0.3 2.3 1.1 1.5 0.4 2.3 0.7 116 10 127 300 -4.8 0 -4.6 -4.8 11/10/2005 04:40:00 2 0.5 3 0.7 1.9 0.5 3 0.7 1.4 0.4 2.3 0.4 115 11 135 300 -4.8 0 -4.6 -4.8 11/10/2005 04:50:00 1.5 0.6 3.4 0.4 1.3 0.7 3 0.4 0.7 0.5 2.6 0.4 102 17 122 300 -5 0 -4.8 -5 11/10/2005 05:00:00 1.5 0.6 3 0.4 1.3 0.6 3 0.4 0.9 0.5 2.6 0.4 141 11 146 300 -5.2 0 -5 -5.5 11/10/2005 05:10:00 1.5 0.3 2.3 0.7 1.3 0.4 2.3 0.4 0.9 0.4 1.9 0.4 134 27 89 300 -5.6 0.2 -5.3 -6.1 11/10/2005 05:20:00 2.2 0.5 3.4 1.1 2.1 0.5 3 0.7 1.6 0.5 2.6 0.4 107 15 134 300 -6 0 -5.7 -6.1 11/10/2005 05:30:00 1.5 0.5 2.6 0.4 1.2 0.5 2.3 0.4 0.7 0.4 1.9 0.4 109 16 127 300 -6.2 0 -6.1 -6.6 11/10/2005 05:40:00 1.2 0.5 2.3 0.4 0.9 0.5 1.9 0.4 0.5 0.3 1.5 0.4 112 24 131 300 -6.1 0 -5.9 -6.1 11/10/2005 05:50:00 0.8 0.4 1.9 0.4 0.6 0.3 1.5 0.4 0.9 0.5 1.9 0.4 75 28 52 300 -6.2 0 -5.9 -6.4 11/10/2005 06:00:00 0.9 0.5 2.3 0.4 0.7 0.4 2.3 0.4 0.6 0.3 1.5 0.4 147 26 138 300 -6.1 0 -5.7 -6.4 11/10/2005 06:10:00 1.7 0.9 3.4 0.4 1.6 0.8 3 0.4 1.3 0.7 3 0.4 123 24 107 300 -6.1 0.1 -5.7 -6.4 11/10/2005 06:20:00 1.7 0.8 3.4 0.4 1.6 0.8 3.4 0.4 1.5 0.5 2.6 0.4 97 32 103 300 -6.4 0.1 -5.9 -6.6 11/10/2005 06:30:00 1.7 0.7 3 0.4 1.5 0.7 2.6 0.4 1.5 0.6 3 0.4 114 10 104 300 -6.1 0.1 -5.9 -6.4 11/10/2005 06:40:00 2.8 0.4 3.8 1.5 2.6 0.4 3.4 1.5 2.2 0.5 3.4 1.1 98 20 92 300 -6.8 0.2 -6.1 -7 11/10/2005 06:50:00 2.4 0.6 3 0.4 2.2 0.6 3 0.4 2 0.6 3.4 0.4 126 24 107 300 -6.5 0.1 -6.1 -6.8 11/10/2005 07:00:00 2.2 0.6 3.4 0.7 2 0.7 3.4 0.4 1.3 0.6 3 0.4 134 18 141 300 -6.8 0.3 -6.1 -7.2 11/10/2005 07:10:00 1.6 0.8 3.4 0.4 1.5 0.8 3.4 0.4 1.1 0.7 2.6 0.4 138 11 152 300 -7.1 0 -6.8 -7.2 11/10/2005 07:20:00 2.7 0.6 4.2 0.7 2.5 0.6 4.2 0.7 2.4 0.7 4.2 1.1 106 45 32 300 -6.9 0.1 -6.6 -7.2 11/10/2005 07:30:00 1.2 1 4.2 0.4 1.1 1 3.8 0.4 0.9 0.9 3.4 0.4 150 26 199 300 -6.3 0.2 -6.1 -7 11/10/2005 07:40:00 1.1 0.6 2.3 0.4 0.9 0.5 2.3 0.4 0.8 0.5 1.9 0.4 132 35 147 300 -6.7 0 -6.4 -6.8 11/10/2005 07:50:00 1.3 0.7 3 0.4 1.2 0.7 2.6 0.4 0.9 0.5 2.3 0.4 182 41 182 300 -6.6 0 -6.4 -6.8 11/10/2005 08:00:00 0.8 0.4 1.9 0.4 0.8 0.6 2.3 0.4 0.7 0.5 2.3 0.4 194 15 208 300 -6.8 0.1 -6.6 -7 11/10/2005 08:10:00 1.5 0.5 2.6 0.4 1.5 0.6 3 0.4 1 0.6 2.6 0.4 193 9 197 300 -6.8 0.2 -6.6 -7 11/10/2005 08:20:00 1.8 0.7 3.4 0.4 1.7 0.8 3.4 0.4 1.3 0.7 3 0.4 173 12 181 300 -7 0.2 -6.6 -7.4 11/10/2005 08:30:00 1.5 0.4 2.6 0.4 1.5 0.6 3 0.4 1.3 0.4 2.3 0.4 187 19 198 300 -7.4 0 -7.2 -7.6 11/10/2005 08:40:00 1.9 0.5 3.4 0.7 2.1 0.6 3.4 1.1 1.6 0.7 3 0.4 203 10 221 300 -7.3 0 -7 -7.4 11/10/2005 08:50:00 1.7 0.6 2.6 0.4 1.8 0.8 3 0.4 1.5 0.7 2.3 0.4 199 12 202 300 -7.2 0.1 -7 -7.4 11/10/2005 09:00:00 1.9 0.5 3.4 0.7 2 0.7 4.2 0.4 1.4 0.7 3 0.4 195 12 224 300 -7.5 0.1 -7 -7.6 11/10/2005 09:10:00 1.9 0.4 2.6 1.1 2.1 0.4 3 1.1 1.5 0.3 2.3 0.7 207 9 203 300 -7.3 0.1 -7 -7.6 11/10/2005 09:20:00 2.1 0.4 3 1.1 2.1 0.4 3 1.1 1.5 0.4 2.3 0.4 221 5 223 300 -7.6 0.1 -7.2 -7.9 11/10/2005 09:30:00 2.1 0.3 2.6 1.1 1.8 0.4 2.6 0.7 1.1 0.5 1.9 0.4 243 8 235 300 -7.2 0 -7 -7.2 11/10/2005 09:40:00 2.6 0.6 3.8 1.5 2.5 0.6 3.8 1.1 1.8 0.5 3.4 0.7 241 13 226 300 -7.2 0.2 -6.6 -7.4 11/10/2005 09:50:00 2.3 0.3 3 1.5 2.2 0.4 3 1.1 1.8 0.4 2.6 1.1 251 7 254 300 -7.1 0.2 -6.6 -7.4 11/10/2005 10:00:00 2.9 0.4 4.2 1.5 2.8 0.5 3.8 1.5 2.1 0.5 3.4 0.7 241 8 254 300 -6.2 0.2 -5.9 -7 11/10/2005 10:10:00 3.1 0.5 4.2 1.5 3 0.4 4.2 1.9 2.3 0.5 3.4 0.7 236 8 238 300 -5.6 0.2 -5 -5.9 11/10/2005 10:20:00 2.7 0.3 3.8 1.9 2.6 0.3 3.4 1.9 2 0.3 3 1.1 231 6 226 300 -4.8 0.2 -4.4 -5.3 11/10/2005 10:30:00 2.5 0.5 3.4 1.1 2.5 0.5 3.4 1.1 1.9 0.5 3 0.4 228 8 231 300 -4.3 0 -4.2 -4.4 11/10/2005 10:40:00 2.3 0.7 3.8 0.7 2.1 0.7 3.8 0.4 1.6 0.7 3.4 0.4 239 14 230 300 -4 0 -3.7 -4.4 11/10/2005 10:50:00 2.9 0.7 4.6 1.1 2.8 0.7 4.2 0.7 2.3 0.8 4.2 0.4 234 12 240 300 -3.8 0 -3.7 -3.9 11/10/2005 11:00:00 2.6 0.6 4.2 1.5 2.6 0.6 4.6 1.5 1.9 0.6 3.4 0.4 227 17 254 300 -3.7 0.1 -3.5 -3.9 11/10/2005 11:10:00 2.5 0.6 4.2 0.7 2.5 0.6 4.2 0.7 2.2 0.6 3.4 0.4 225 11 227 300 -3.4 0 -3.3 -3.5 11/10/2005 11:20:00 2.2 0.6 4.2 0.7 2.3 0.6 3.8 0.7 1.9 0.6 3 0.4 220 22 250 300 -3.1 0 -2.8 -3.5 11/10/2005 11:30:00 2.3 0.6 3.8 0.7 2.3 0.7 3.8 0.7 2.3 0.5 3.8 0.7 216 15 226 300 -3.1 0 -2.8 -3.3 11/10/2005 11:40:00 1.4 0.5 3 0.4 1.4 0.6 3 0.4 1.3 0.5 2.6 0.4 199 19 218 300 -2.9 0.1 -2.6 -3.3 11/10/2005 11:50:00 1.4 0.6 3 0.4 1.4 0.6 3 0.4 1.3 0.5 2.3 0.4 191 17 223 300 -2.4 0 -2.1 -2.6 11/10/2005 12:00:00 1.9 0.7 3.4 0.4 1.9 0.7 3.4 0.4 1.6 0.7 3 0.4 191 17 192 300 -2.5 0.1 -2.1 -2.6 11/10/2005 12:10:00 2.1 0.8 4.6 0.4 2.1 0.8 4.2 0.4 1.9 0.8 3.4 0.4 222 23 229 300 -2.5 0 -2.1 -2.6 11/10/2005 12:20:00 3.3 0.8 5.3 1.1 3.3 0.8 5.3 0.7 2.9 0.8 4.6 1.1 228 13 218 300 -2.1 0.1 -1.9 -2.4 11/10/2005 12:30:00 2.4 0.8 4.2 0.4 2.6 0.9 4.6 0.4 2.3 0.9 4.6 0.4 210 16 196 300 -1.8 0 -1.4 -1.9 11/10/2005 12:40:00 2 0.7 3.8 0.4 1.8 0.7 3.4 0.4 2 0.6 3.4 0.4 236 20 247 300 -1.7 0 -1.4 -1.9 11/10/2005 12:50:00 2.2 1 4.6 0.4 2.1 1 4.6 0.4 2 0.9 4.6 0.4 232 18 226 300 -1.6 0 -1.4 -1.9 11/10/2005 13:00:00 2.9 0.9 4.6 0.4 2.9 0.9 4.6 0.4 2.5 0.8 4.2 0.4 223 11 222 300 -1.4 0 -1.2 -1.4 11/10/2005 13:10:00 2.2 0.8 4.2 0.4 2.3 0.8 4.6 0.4 2.2 0.8 4.2 0.4 203 17 185 300 -1.2 0 -1 -1.4 11/10/2005 13:20:00 2.2 0.7 4.2 0.4 2.4 0.8 4.2 0.4 2.1 0.8 4.2 0.7 194 19 181 300 -1.2 0 -1 -1.4 11/10/2005 13:30:00 1.8 0.4 3 0.7 1.8 0.5 3 0.7 1.7 0.5 2.6 0.4 184 17 174 300 -1 0 -1 -1.2 11/10/2005 13:40:00 1.6 0.5 3.4 0.4 1.5 0.5 3 0.4 1.5 0.4 3 0.4 195 22 174 300 -1 0 -0.7 -1 11/10/2005 13:50:00 1.5 0.6 2.6 0.4 1.4 0.6 2.6 0.4 1.6 0.6 2.6 0.4 189 14 193 300 -0.9 0.1 -0.5 -1.2 11/10/2005 14:00:00 1.5 0.6 2.6 0.4 1.4 0.6 2.6 0.4 1.5 0.5 2.6 0.4 178 15 181 300 -1.2 0 -1 -1.4 11/10/2005 14:10:00 1.7 0.4 2.6 0.4 1.5 0.5 2.6 0.4 1.6 0.5 2.6 0.4 172 11 167 300 -1.3 0 -1 -1.4 11/10/2005 14:20:00 1.5 0.4 2.6 0.4 1.3 0.5 2.3 0.4 1.3 0.4 2.3 0.4 149 11 151 300 -1.3 0 -1.2 -1.4 11/10/2005 14:30:00 1 0.4 1.9 0.4 0.8 0.4 1.5 0.4 0.9 0.4 1.9 0.4 129 11 132 300 -1.3 0 -1.2 -1.4 11/10/2005 14:40:00 1.7 0.4 2.6 0.7 1.6 0.4 2.3 0.4 1.4 0.5 2.6 0.4 134 8 145 300 -1.3 0.1 -1 -1.4 11/10/2005 14:50:00 1.6 0.4 2.6 0.7 1.4 0.5 2.6 0.4 1.3 0.5 2.6 0.4 128 8 123 300 -1.4 0 -1.2 -1.4 11/10/2005 15:00:00 1.5 0.4 2.3 0.4 1.3 0.4 2.3 0.4 0.9 0.4 1.9 0.4 128 8 118 300 -1.6 0 -1.4 -1.7 11/10/2005 15:10:00 1.1 0.5 1.9 0.4 0.9 0.4 1.9 0.4 0.7 0.4 2.3 0.4 121 9 114 300 -1.7 0 -1.4 -1.9 11/10/2005 15:20:00 1.3 0.4 1.9 0.4 1.1 0.4 1.9 0.4 1 0.5 1.9 0.4 116 9 131 300 -2 0.1 -1.7 -2.1 11/10/2005 15:30:00 1.3 0.4 1.9 0.4 1.1 0.4 1.9 0.4 1.1 0.4 1.9 0.4 108 12 116 300 -2.1 0 -2.1 -2.1 11/10/2005 15:40:00 1.3 0.3 1.9 0.7 1.1 0.3 1.9 0.4 1.2 0.3 1.9 0.4 111 16 84 300 -2.4 0 -2.1 -2.6 11/10/2005 15:50:00 1.4 0.4 1.9 0.4 1.2 0.4 1.9 0.4 1.2 0.4 1.9 0.4 92 10 109 300 -2.7 0 -2.6 -2.8 11/10/2005 16:00:00 1.5 0.2 1.9 0.7 1.3 0.2 1.5 0.4 1.2 0.2 1.9 0.7 95 3 96 300 -3 0 -2.8 -3 11/10/2005 16:10:00 1.3 0.3 1.9 0.7 1.1 0.3 1.5 0.4 1.1 0.3 1.9 0.4 76 5 82 300 -3.1 0 -2.8 -3.3 11/10/2005 16:20:00 1.9 0.2 2.6 1.1 1.7 0.3 2.3 1.1 1.7 0.3 2.3 1.1 59 8 51 300 -3.4 0.1 -3.3 -3.5 11/10/2005 16:30:00 2.2 0.3 3 1.5 2.1 0.3 3 1.5 1.9 0.4 3 1.1 54 5 56 300 -3.8 0 -3.5 -3.7 11/10/2005 16:40:00 2.3 0.3 3 1.5 2.2 0.4 3 1.1 1.8 0.5 3 0.4 54 15 51 300 -3.9 0.1 -3.7 -4.2 11/10/2005 16:50:00 2.3 0.3 3 1.5 2.1 0.3 2.6 1.1 1.8 0.4 2.6 0.7 49 14 39 300 -4.1 0 -3.9 -4.2 11/10/2005 17:00:00 2.5 0.3 3.4 1.9 2.4 0.4 3.4 1.5 1.9 0.4 3 0.7 45 9 45 300 -4.3 0 -3.9 -4.6 11/10/2005 17:10:00 2.5 0.4 3.4 1.5 2.4 0.4 3.4 1.5 2 0.4 3 1.1 53 6 65 300 -4.6 0 -4.2 -4.6 11/10/2005 17:20:00 2.5 0.2 3 1.9 2.4 0.3 3 1.5 1.9 0.3 2.6 1.1 51 8 52 300 -4.8 0 -4.6 -4.8 11/10/2005 17:30:00 2.8 0.3 3.8 2.3 2.7 0.3 3.4 1.9 1.9 0.4 3 0.7 39 15 14 300 -4.9 0 -4.8 -5 11/10/2005 17:40:00 2.8 0.5 3.8 1.5 2.8 0.5 3.4 1.1 2.2 0.4 3 0.7 64 5 68 300 -4.9 0 -4.8 -5 11/10/2005 17:50:00 2.4 0.3 3 1.9 2.3 0.3 3 1.5 1.9 0.3 2.6 1.1 54 8 57 300 -5 0.1 -4.8 -5.3 11/10/2005 18:00:00 2.8 0.2 3.4 2.3 2.7 0.2 3 2.3 2.1 0.4 3 1.1 46 5 43 300 -5.1 0 -4.8 -5.3 11/10/2005 18:10:00 2.8 0.2 3 2.3 2.8 0.2 3 2.3 2.1 0.4 2.6 1.1 48 8 56 300 -4.9 0 -4.8 -5 11/10/2005 18:20:00 2.8 0.2 3.4 2.3 2.8 0.2 3.4 2.3 2 0.4 3 1.1 42 4 44 300 -4.9 0 -4.8 -5 11/10/2005 18:30:00 2.8 0.2 3.4 2.3 2.8 0.2 3 2.3 1.9 0.3 2.6 1.1 41 7 37 300 -4.9 0 -4.8 -5 11/10/2005 18:40:00 3.1 0.3 3.8 2.6 3.1 0.3 3.8 2.3 2.4 0.3 3 1.5 48 5 53 300 -4.9 0 -4.8 -5 11/10/2005 18:50:00 3.1 0.3 3.8 2.3 3.1 0.3 3.8 2.3 2.3 0.4 3.4 1.5 42 3 43 300 -5.2 0 -5 -5.3 11/10/2005 19:00:00 2.9 0.3 3.4 2.3 2.9 0.3 3.4 2.3 2.1 0.4 3 1.1 44 6 44 300 -5.1 0 -5 -5.3 11/10/2005 19:10:00 2.9 0.2 3.4 2.3 2.8 0.2 3.4 1.9 1.9 0.4 3 0.7 41 6 42 300 -5.1 0 -5 -5.3 11/10/2005 19:20:00 3 0.2 3.4 2.3 2.9 0.2 3.4 2.3 2.2 0.3 3 1.5 46 3 47 300 -5.2 0.1 -5 -5.5 11/10/2005 19:30:00 3.1 0.2 3.4 2.6 3.1 0.2 3.4 2.3 2.3 0.4 3 1.1 44 6 46 300 -5.6 0 -5.5 -5.7 11/10/2005 19:40:00 3.2 0.2 3.8 2.6 3.2 0.2 3.4 2.6 2.2 0.4 3 1.5 43 5 41 300 -5.3 0.1 -5 -5.7 11/10/2005 19:50:00 3.2 0.2 3.8 2.6 3.2 0.2 3.8 2.6 2.6 0.3 3.4 1.9 47 3 45 300 -5.1 0 -5 -5.3 11/10/2005 20:00:00 3.3 0.2 3.8 2.6 3.3 0.2 3.8 2.6 2.6 0.3 3.4 1.9 51 4 50 300 -5.4 0 -5.3 -5.5 11/10/2005 20:10:00 3.5 0.2 3.8 3 3.5 0.2 4.2 3 2.7 0.3 3.4 1.5 50 4 53 300 -5.5 0.1 -5.3 -5.7 11/10/2005 20:20:00 3.3 0.3 4.2 2.3 3.3 0.3 4.2 2.3 2.4 0.4 3.4 1.5 44 3 52 300 -5.6 0 -5.5 -5.9 11/10/2005 20:30:00 3.4 0.2 3.8 2.6 3.4 0.2 3.8 2.3 2.5 0.4 3.4 1.5 42 4 48 300 -5.6 0 -5.5 -5.7 11/10/2005 20:40:00 3.3 0.3 3.8 2.6 3.2 0.3 3.8 2.6 2.1 0.4 3 1.1 39 3 37 300 -5.3 0 -5.3 -5.5 11/10/2005 20:50:00 3.4 0.3 3.8 2.6 3.4 0.3 4.2 2.3 2.6 0.4 3.4 1.1 47 5 45 300 -5.2 0 -5 -5.5 11/10/2005 21:00:00 3.5 0.3 4.2 2.6 3.5 0.3 4.2 2.6 2.7 0.4 3.8 1.5 46 4 52 300 -5.3 0 -5 -5.5 11/10/2005 21:10:00 3.5 0.3 4.2 2.6 3.4 0.4 4.2 2.3 2.5 0.4 3.8 1.5 41 5 50 300 -5.3 0 -5 -5.5 11/10/2005 21:20:00 3.5 0.3 4.2 2.6 3.5 0.4 4.2 1.9 2.2 0.4 3.4 1.1 36 5 40 300 -5.1 0 -4.8 -5.3 11/10/2005 21:30:00 3.5 0.3 4.2 2.6 3.4 0.4 4.2 2.3 2.2 0.4 3.4 1.5 35 5 33 300 -5.1 0 -5 -5.3 11/10/2005 21:40:00 3.5 0.3 4.2 2.3 3.4 0.4 4.2 1.9 2.5 0.4 3.4 1.5 39 6 40 300 -5.1 0.1 -4.8 -5.3 11/10/2005 21:50:00 3.3 0.3 4.2 2.3 3.3 0.4 4.2 2.3 2.4 0.5 3.4 1.1 41 7 54 300 -4.9 0 -4.6 -5 11/10/2005 22:00:00 3.5 0.3 4.2 2.6 3.4 0.4 4.2 2.3 2.4 0.5 3.8 1.1 39 6 40 300 -4.9 0 -4.6 -5 11/10/2005 22:10:00 3.4 0.4 4.6 2.3 3.4 0.4 4.6 2.3 2.4 0.5 3.4 1.1 41 6 38 300 -4.8 0 -4.6 -4.8 11/10/2005 22:20:00 3.4 0.4 4.6 2.3 3.3 0.5 4.6 1.9 2.3 0.5 3.8 1.1 39 6 37 300 -4.8 0 -4.6 -4.8 11/10/2005 22:30:00 3.3 0.4 4.2 2.3 3.2 0.4 4.2 2.3 2.1 0.5 3.8 0.7 37 5 38 300 -4.7 0 -4.6 -4.8 11/10/2005 22:40:00 3 0.5 4.2 1.5 2.8 0.5 4.2 1.5 1.9 0.5 3.4 1.1 37 8 36 300 -4.6 0 -4.4 -4.6 11/10/2005 22:50:00 2.6 0.6 3.8 1.5 2.2 0.6 3.8 0.7 1.5 0.5 2.6 0.4 28 8 32 300 -4.2 0.1 -3.9 -4.6 11/10/2005 23:00:00 2.8 0.4 3.8 1.9 2.7 0.4 3.8 1.9 1.8 0.4 2.6 0.7 40 6 34 300 -4.4 0 -4.4 -4.6 11/10/2005 23:10:00 2.6 0.3 3.4 1.9 2.6 0.3 3.4 1.5 1.7 0.3 2.6 0.7 41 4 49 300 -4.4 0.1 -4.2 -4.6 11/10/2005 23:20:00 2.8 0.3 3.8 2.3 2.6 0.3 3.8 1.9 1.5 0.4 2.6 0.7 35 3 39 300 -4.2 0 -4.2 -4.4 11/10/2005 23:30:00 2.9 0.3 3.8 1.9 2.7 0.4 3.8 1.5 1.8 0.4 3 1.1 36 5 37 300 -4.3 0 -4.2 -4.6 11/10/2005 23:40:00 2.6 0.4 3.4 1.5 2.6 0.4 3.4 1.5 1.8 0.4 2.6 1.1 47 7 32 300 -4.4 0.1 -4.2 -4.6 11/10/2005 23:50:00 2.4 0.3 3.4 1.5 2.3 0.3 3 1.5 1.7 0.3 2.6 0.7 50 5 55 300 -4 0 -3.7 -4.4 11/11/2005 00:00:00 2.3 0.4 3.8 1.1 2.3 0.4 3.8 1.1 1.7 0.4 3 0.7 50 8 54 300 -3.8 0 -3.7 -3.7 11/11/2005 00:10:00 2.2 0.6 3.4 1.1 2.1 0.6 3.4 0.7 1.2 0.6 2.6 0.4 56 7 54 300 -3.9 0.2 -3.7 -4.6 11/11/2005 00:20:00 1.2 0.4 2.3 0.4 1 0.4 2.3 0.4 0.4 0.2 1.5 0.4 50 7 71 300 -5.4 0.4 -4.6 -6.1 11/11/2005 00:30:00 1.2 0.5 2.3 0.4 1 0.5 2.3 0.4 0.4 0.1 1.1 0.4 46 9 44 300 -6.4 0.1 -5.9 -6.6 11/11/2005 00:40:00 0.8 0.5 2.6 0.4 0.6 0.5 2.6 0.4 0.6 0.3 1.5 0.4 52 15 45 300 -6.5 0 -6.6 -6.6 11/11/2005 00:50:00 0.6 0.3 2.3 0.4 0.5 0.3 2.3 0.4 1.7 0.4 2.6 0.7 175 39 220 300 -6.6 0 -6.6 -6.8 11/11/2005 01:00:00 1.9 0.5 2.6 0.7 1.9 0.5 2.6 0.7 1.7 0.4 2.6 0.7 217 5 211 300 -6.7 0 -6.6 -6.8 11/11/2005 01:10:00 2.2 0.4 3 1.1 2.1 0.4 2.6 1.1 1.2 0.5 2.3 0.4 233 5 227 300 -6.8 0 -6.6 -7 11/11/2005 01:20:00 1.6 0.2 2.3 1.1 1.4 0.2 1.9 1.1 0.8 0.2 1.1 0.4 243 0 243 300 -6.9 0 -6.8 -7 11/11/2005 01:30:00 1.6 0.4 2.6 1.1 1.4 0.4 2.3 0.7 1 0.3 1.9 0.4 246 5 243 300 -6.9 0 -6.8 -7 11/11/2005 01:40:00 1.9 0.2 2.3 1.5 1.7 0.2 2.3 1.1 1.5 0.2 1.9 0.7 246 9 258 300 -6.8 0 -6.8 -7 11/11/2005 01:50:00 2 0.2 2.3 1.5 1.7 0.2 2.3 1.5 1.6 0.2 1.9 1.1 239 3 245 300 -6.7 0 -6.6 -7 11/11/2005 02:00:00 1.9 0.3 2.6 1.1 1.7 0.3 2.3 1.1 1.6 0.2 1.9 1.1 241 3 237 300 -6.3 0.1 -5.9 -6.8 11/11/2005 02:10:00 1.3 0.5 2.3 0.4 1.1 0.5 1.9 0.4 1.1 0.4 1.9 0.4 259 9 254 300 -6 0 -5.9 -6.1 11/11/2005 02:20:00 0.5 0.3 1.5 0.4 0.4 0.2 1.1 0.4 0.7 0.4 1.5 0.4 327 28 285 300 -6.1 0 -5.9 -6.1 11/11/2005 02:30:00 0.4 0 0.7 0.4 0.4 0 0.7 0.4 0.5 0.2 1.1 0.4 290 43 265 300 -6 0 -5.9 -6.1 11/11/2005 02:40:00 0.4 0.2 1.1 0.4 0.4 0.2 1.1 0.4 0.4 0.1 0.7 0.4 57 26 18 300 -6 0 -5.9 -6.1 11/11/2005 02:50:00 0.4 0.1 0.7 0.4 0.4 0 0.4 0.4 0.4 0.1 1.1 0.4 56 2 55 300 -5.8 0 -5.7 -5.9 11/11/2005 03:00:00 0.4 0.1 1.1 0.4 0.4 0.1 1.1 0.4 0.4 0 0.4 0.4 55 5 55 300 -5.6 0 -5.5 -5.7 11/11/2005 03:10:00 1.2 0.3 1.9 0.4 1 0.3 1.5 0.4 0.5 0.2 1.1 0.4 43 3 41 300 -5.6 0 -5.5 -5.7 11/11/2005 03:20:00 2.1 0.4 3.4 1.1 2 0.5 3.4 1.1 1.5 0.5 2.6 0.4 55 4 66 300 -5.7 0 -5.5 -5.7 11/11/2005 03:30:00 2.9 0.3 3.8 2.3 2.9 0.3 3.8 2.3 2.3 0.3 3.4 1.5 46 4 39 300 -5.7 0 -5.5 -5.7 11/11/2005 03:40:00 2.4 0.7 3.8 0.4 2.4 0.7 3.8 0.4 1.7 0.6 3 0.4 53 11 42 300 -5.3 0.1 -5 -5.7 11/11/2005 03:50:00 1.3 0.4 2.3 0.4 1.1 0.4 2.3 0.4 1 0.4 2.3 0.4 68 12 65 300 -5.6 0 -5.3 -5.7 11/11/2005 04:00:00 1.3 0.4 2.6 0.4 1.1 0.4 2.6 0.4 0.8 0.3 1.5 0.4 63 6 52 300 -5.6 0 -5.5 -5.7 11/11/2005 04:10:00 2.3 0.5 3.8 1.5 2.2 0.5 3.8 1.5 1.4 0.4 2.6 0.7 61 3 55 300 -5.5 0 -5.5 -5.7 11/11/2005 04:20:00 3 0.4 4.2 1.9 3 0.4 4.2 1.9 2 0.5 3.4 0.7 57 5 53 300 -5.4 0 -5.5 -5.5 11/11/2005 04:30:00 2.5 0.3 3.4 1.5 2.4 0.4 3.4 1.5 1.7 0.4 2.6 0.7 51 4 52 300 -5.3 0 -5 -5.5 11/11/2005 04:40:00 1.8 0.4 3 1.1 1.7 0.4 3 0.7 0.9 0.4 2.3 0.4 52 6 47 300 -5 0 -4.8 -5 11/11/2005 04:50:00 2.6 0.6 4.2 0.7 2.5 0.6 4.6 0.7 1.6 0.7 3.4 0.4 45 10 38 300 -4.9 0.1 -4.6 -5 11/11/2005 05:00:00 2.7 0.6 4.6 1.1 2.7 0.6 4.6 1.1 1.8 0.6 3 0.4 50 8 48 300 -4.5 0 -4.4 -4.6 11/11/2005 05:10:00 2.2 0.7 3.8 0.4 2.1 0.8 4.2 0.4 1.4 0.7 3 0.4 60 17 59 300 -4.5 0 -4.4 -4.6 11/11/2005 05:20:00 1.5 0.6 3.4 0.4 1.4 0.7 3.4 0.4 1.1 0.5 2.3 0.4 87 32 59 300 -4.7 0.1 -4.4 -5 11/11/2005 05:30:00 1.3 0.7 3 0.4 1.2 0.7 2.6 0.4 0.9 0.5 2.3 0.4 94 30 57 300 -5 0 -5 -5 11/11/2005 05:40:00 2.1 0.5 3.4 0.7 1.9 0.6 3.4 0.4 1.4 0.5 2.6 0.4 51 10 55 300 -4.9 0.1 -4.6 -5 11/11/2005 05:50:00 2.4 0.5 3.4 0.7 2.2 0.6 3.4 0.7 1.5 0.5 3 0.4 42 13 54 300 -4.4 0 -4.4 -4.6 11/11/2005 06:00:00 2.2 0.5 3.8 0.7 2 0.6 3.4 0.7 1.5 0.5 3.4 0.4 40 10 42 300 -4.3 0 -4.2 -4.4 11/11/2005 06:10:00 2 0.4 3.4 0.7 1.8 0.4 3 0.7 1.3 0.4 2.6 0.4 39 11 42 300 -4.3 0 -4.4 -4.4 11/11/2005 06:20:00 2.3 0.7 3.8 0.4 1.9 0.7 3.4 0.4 1.4 0.6 3 0.4 32 13 24 300 -4.3 0 -4.4 -4.4 11/11/2005 06:30:00 1 0.6 2.3 0.4 0.9 0.6 2.6 0.4 0.7 0.4 2.3 0.4 39 13 52 300 -4.4 0 -4.4 -4.6 11/11/2005 06:40:00 1.5 0.6 3 0.4 1.3 0.6 3 0.4 0.9 0.4 2.3 0.4 46 15 20 300 -4.5 0 -4.4 -4.6 11/11/2005 06:50:00 1.6 0.7 3.4 0.4 1.4 0.7 3 0.4 1.3 0.6 2.6 0.4 43 12 39 300 -4.5 0 -4.4 -4.6 11/11/2005 07:00:00 1.5 0.5 3.4 0.4 1.4 0.6 3 0.4 1.2 0.5 2.6 0.4 51 15 39 300 -4.5 0 -4.4 -4.6 11/11/2005 07:10:00 1.4 0.5 2.6 0.4 1.2 0.5 2.6 0.4 1 0.5 3 0.4 33 15 41 300 -4.6 0 -4.4 -4.6 11/11/2005 07:20:00 2.7 0.6 4.6 0.7 2.4 0.7 4.2 0.7 1.9 0.6 3.4 0.7 33 9 29 300 -4.6 0 -4.6 -4.6 11/11/2005 07:30:00 2.6 0.5 3.8 1.5 2.4 0.5 3.8 1.1 2 0.6 3.8 0.4 38 12 51 300 -4.6 0 -4.6 -4.6 11/11/2005 07:40:00 2.9 0.5 4.2 1.5 2.7 0.6 4.2 1.1 2 0.6 3.8 0.7 38 13 49 300 -4.5 0 -4.4 -4.6 11/11/2005 07:50:00 2.4 0.7 3.8 0.4 2.1 0.7 3.8 0.4 1.7 0.6 3.4 0.4 38 12 59 300 -4.4 0 -4.4 -4.6 11/11/2005 08:00:00 2.1 0.6 3.4 0.7 1.9 0.6 3.4 0.4 1.4 0.5 2.6 0.4 49 13 35 300 -4.3 0 -4.4 -4.4 11/11/2005 08:10:00 1.5 0.5 3 0.4 1.3 0.5 3 0.4 0.9 0.5 2.3 0.4 62 13 57 300 -4.3 0 -4.4 -4.4 11/11/2005 08:20:00 1.4 0.4 2.3 0.4 1.1 0.4 2.3 0.4 0.7 0.4 1.9 0.4 41 8 31 300 -4.3 0 -4.4 -4.6 11/11/2005 08:30:00 1.9 0.5 3 0.7 1.7 0.5 2.6 0.4 1.3 0.5 2.6 0.4 38 9 44 300 -4.4 0 -4.4 -4.4 11/11/2005 08:40:00 2.6 0.5 4.2 1.1 2.3 0.5 3.4 0.7 1.8 0.5 3 0.7 32 9 25 300 -4.3 0 -4.2 -4.4 11/11/2005 08:50:00 2.2 0.6 3.4 0.7 1.9 0.6 3.4 0.4 1.4 0.6 2.6 0.4 33 10 45 300 -4 0 -3.9 -4.4 11/11/2005 09:00:00 2.8 0.7 4.9 1.1 2.5 0.7 4.6 0.7 2 0.7 3.8 0.7 36 14 33 300 -3.8 0 -3.7 -3.9 11/11/2005 09:10:00 2.1 0.8 3.8 0.4 1.9 0.8 3.8 0.4 1.5 0.7 3.4 0.4 42 16 6 300 -3.9 0 -3.7 -3.9 11/11/2005 09:20:00 2.2 0.7 4.2 0.4 2 0.8 4.2 0.4 1.6 0.7 4.2 0.4 47 21 28 300 -3.8 0 -3.7 -3.9 11/11/2005 09:30:00 2.3 0.7 4.2 0.7 2.2 0.8 4.2 0.4 1.6 0.7 4.2 0.4 51 16 67 300 -3.8 0 -3.7 -3.7 11/11/2005 09:40:00 2.5 0.7 4.2 0.4 2.3 0.7 4.2 0.4 1.6 0.8 3.4 0.4 52 19 41 300 -3.7 0 -3.5 -3.7 11/11/2005 09:50:00 2.4 0.9 4.9 0.7 2.3 1 4.6 0.4 1.9 0.9 4.2 0.4 59 17 27 300 -3.4 0 -3.3 -3.5 11/11/2005 10:00:00 2.3 0.6 4.2 0.4 2.2 0.7 3.8 0.4 1.6 0.6 3.4 0.4 56 13 61 300 -3.4 0 -3.3 -3.5 11/11/2005 10:10:00 1.7 0.6 3.4 0.4 1.6 0.6 3 0.4 1.5 0.5 3.4 0.4 87 30 60 300 -3.5 0.2 -3.3 -3.9 11/11/2005 10:20:00 1.7 0.4 2.6 0.7 1.5 0.3 2.3 0.4 1.5 0.3 2.3 0.7 169 21 188 300 -4.1 0.1 -3.9 -4.4 11/11/2005 10:30:00 1.4 0.4 2.3 0.7 1.6 0.3 2.3 1.1 1.6 0.3 2.3 0.7 201 9 185 300 -4.3 0 -4.2 -4.4 11/11/2005 10:40:00 1.6 0.4 2.6 0.7 1.7 0.3 2.6 0.7 1.5 0.4 2.6 0.4 213 6 215 300 -4.4 0 -4.4 -4.6 11/11/2005 10:50:00 2.3 0.4 3 1.1 2.3 0.3 3 1.5 2.1 0.4 3 0.7 218 3 220 300 -4.5 0 -4.4 -4.6 11/11/2005 11:00:00 2 0.7 3.8 0.7 2.3 0.7 3.4 0.7 2 0.6 3.4 0.7 212 6 219 300 -4.6 0 -4.4 -4.6 11/11/2005 11:10:00 2.1 0.5 3 0.7 2.2 0.5 3 1.1 1.7 0.6 3 0.4 213 7 218 300 -4.5 0 -4.4 -4.6 11/11/2005 11:20:00 1.6 0.4 2.6 0.7 1.8 0.4 2.6 0.7 1.5 0.4 2.6 0.7 211 7 197 300 -4.3 0 -4.4 -4.6 11/11/2005 11:30:00 1.5 0.4 2.6 0.4 1.5 0.5 2.6 0.4 1.3 0.4 2.3 0.4 214 9 222 300 -4.2 0 -3.9 -4.4 11/11/2005 11:40:00 2.3 0.4 3 1.1 2.3 0.4 3 1.1 2.1 0.4 3 0.7 222 6 220 300 -4 0 -3.9 -4.2 11/11/2005 11:50:00 2 0.4 3 0.7 2 0.4 3 0.7 1.8 0.4 2.6 0.7 221 7 207 300 -3.8 0 -3.7 -3.9 11/11/2005 12:00:00 2.1 0.6 3.4 0.4 2 0.6 3.4 0.4 1.8 0.5 3 0.4 221 6 223 300 -3.8 0 -3.5 -3.7 11/11/2005 12:10:00 1.5 0.4 2.3 0.4 1.4 0.4 2.3 0.4 1.4 0.4 2.3 0.4 219 12 223 300 -3.6 0 -3.3 -3.7 11/11/2005 12:20:00 1.4 0.5 2.3 0.4 1.3 0.6 2.3 0.4 1.3 0.5 2.6 0.4 216 7 225 300 -3.3 0 -3.3 -3.5 11/11/2005 12:30:00 1.7 0.5 2.6 0.4 1.6 0.4 2.6 0.4 1.5 0.5 2.6 0.4 218 10 209 300 -3.1 0 -3 -3.3 11/11/2005 12:40:00 1.7 0.4 3 0.7 1.6 0.4 3 0.4 1.6 0.4 2.6 0.7 222 11 219 300 -3 0 -2.8 -3.3 11/11/2005 12:50:00 2.1 0.4 3 0.7 1.9 0.4 2.6 0.7 1.9 0.4 3 0.7 229 8 225 300 -2.9 0 -2.8 -3 11/11/2005 13:00:00 1.9 0.4 2.6 1.1 1.7 0.4 2.6 0.7 1.8 0.4 2.6 0.7 224 11 228 300 -2.7 0 -2.6 -2.8 11/11/2005 13:10:00 1.8 0.4 3 0.7 1.7 0.5 3 0.7 1.6 0.5 3 0.4 223 13 220 300 -2.5 0 -2.1 -2.6 11/11/2005 13:20:00 1.8 0.6 3.4 0.4 1.9 0.6 3.4 0.4 1.8 0.5 3 0.4 216 13 222 300 -2.4 0 -2.4 -2.6 11/11/2005 13:30:00 2.3 0.6 3.4 0.7 2.3 0.5 3.4 0.7 2 0.6 3 0.7 220 10 227 300 -2.6 0 -2.4 -2.6 11/11/2005 13:40:00 1.5 0.5 2.6 0.4 1.6 0.5 2.6 0.4 1.5 0.5 2.6 0.4 214 15 238 300 -2.7 0 -2.6 -2.8 11/11/2005 13:50:00 2 0.4 3 0.7 2.2 0.5 3 0.7 1.9 0.6 3 0.4 211 10 229 300 -2.9 0 -2.6 -3 11/11/2005 14:00:00 1.8 0.4 2.6 0.4 2.1 0.5 3 0.4 2.1 0.5 3 0.7 205 9 226 300 -3 0 -2.8 -3 11/11/2005 14:10:00 1.7 0.4 2.6 0.7 1.9 0.4 3 0.7 2 0.4 3 1.1 206 6 203 300 -3 0 -2.8 -3.3 11/11/2005 14:20:00 1.5 0.6 2.6 0.4 1.5 0.6 2.6 0.4 1.4 0.5 2.6 0.4 217 12 212 300 -3.1 0 -3 -3.3 11/11/2005 14:30:00 1.1 0.3 2.3 0.4 1.1 0.4 1.9 0.4 1.2 0.4 2.3 0.4 210 10 220 300 -3.1 0 -2.8 -3.3 11/11/2005 14:40:00 1 0.5 1.9 0.4 0.9 0.5 1.9 0.4 1 0.4 1.9 0.4 221 7 246 300 -3 0 -3 -3.3 11/11/2005 14:50:00 0.9 0.3 1.5 0.4 0.8 0.3 1.5 0.4 1.1 0.3 1.5 0.4 214 9 208 300 -3.1 0 -3 -3.3 11/11/2005 15:00:00 0.9 0.5 2.3 0.4 0.8 0.5 2.3 0.4 0.9 0.5 2.3 0.4 213 7 218 300 -3.4 0 -3.3 -3.5 11/11/2005 15:10:00 1.6 0.3 2.6 0.7 1.5 0.3 2.3 0.4 1.4 0.4 2.3 0.4 218 5 204 300 -3.7 0 -3.5 -3.7 11/11/2005 15:20:00 1.3 0.3 1.9 0.4 1 0.3 1.5 0.4 0.9 0.4 1.9 0.4 223 4 222 300 -3.8 0 -3.7 -3.9 11/11/2005 15:30:00 1 0.4 1.9 0.4 0.7 0.4 1.5 0.4 0.7 0.4 1.5 0.4 228 1 229 300 -4.1 0 -3.9 -4.4 11/11/2005 15:40:00 1.3 0.5 2.3 0.4 1.1 0.4 1.9 0.4 1 0.4 1.9 0.4 220 2 219 300 -4.4 0 -4.2 -4.6 11/11/2005 15:50:00 1.3 0.2 1.9 0.7 0.9 0.2 1.5 0.4 1 0.3 1.5 0.4 219 0 219 300 -4.7 0.1 -4.4 -4.8 11/11/2005 16:00:00 1.7 0.2 2.3 1.1 1.5 0.3 1.9 0.7 1.4 0.2 1.9 0.7 221 1 223 300 -4.7 0 -4.6 -4.8 11/11/2005 16:10:00 1.6 0.2 1.9 1.1 1.3 0.2 1.9 0.7 1.3 0.2 1.9 0.7 223 0 223 300 -4.8 0 -4.6 -4.8 11/11/2005 16:20:00 1 0.2 1.5 0.4 0.7 0.3 1.1 0.4 0.6 0.2 1.1 0.4 232 9 222 300 -5.1 0.2 -4.8 -5.5 11/11/2005 16:30:00 0.9 0.2 1.5 0.4 0.6 0.3 1.5 0.4 0.5 0.2 1.5 0.4 237 7 245 300 -5.5 0 -5.3 -5.7 11/11/2005 16:40:00 0.9 0.2 1.5 0.4 0.5 0.3 1.5 0.4 0.5 0.2 1.1 0.4 233 1 235 300 -5.6 0 -5.5 -5.7 11/11/2005 16:50:00 0.8 0.2 1.1 0.4 0.5 0.2 1.1 0.4 0.4 0.1 0.7 0.4 234 0 234 300 -5.7 0.1 -5.5 -5.9 11/11/2005 17:00:00 0.6 0.2 1.1 0.4 0.4 0.1 0.7 0.4 0.4 0.1 0.7 0.4 262 9 262 300 -6 0 -5.7 -5.9 11/11/2005 17:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 269 0 300 300 -6 0 -5.9 -6.4 11/11/2005 17:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.5 0.2 1.1 0.4 269 0 300 300 -6.2 0 -6.1 -6.4 11/11/2005 17:30:00 0.4 0.2 1.5 0.4 0.4 0.2 1.1 0.4 0.4 0.1 0.7 0.4 316 49 22 300 -6.3 0.1 -6.1 -6.6 11/11/2005 17:40:00 0.6 0.3 1.9 0.4 0.5 0.3 1.5 0.4 0.4 0.2 1.5 0.4 30 22 39 300 -6.4 0 -6.4 -6.6 11/11/2005 17:50:00 1.3 0.4 2.6 0.4 1.1 0.4 2.3 0.4 0.9 0.4 1.5 0.4 54 13 69 300 -6.5 0 -6.6 -6.6 11/11/2005 18:00:00 2.1 0.3 3 1.1 2.1 0.3 2.6 1.1 1.8 0.4 2.6 0.7 59 6 72 300 -6.6 0 -6.6 -6.8 11/11/2005 18:10:00 2.6 0.4 3.8 1.5 2.6 0.4 3.8 1.9 2 0.3 3 1.1 56 6 43 300 -6.6 0 -6.6 -6.8 11/11/2005 18:20:00 2.4 0.4 3.8 1.5 2.3 0.5 3.4 1.1 1.9 0.4 3 0.7 47 8 47 300 -6.4 0.2 -5.7 -6.8 11/11/2005 18:30:00 2.9 0.5 4.2 1.9 2.9 0.5 3.8 1.5 2.2 0.4 3 1.1 49 8 60 300 -5.3 0.2 -5 -5.7 11/11/2005 18:40:00 2.9 0.5 4.2 1.9 2.8 0.5 4.2 1.9 2.1 0.5 3.8 1.1 61 8 23 300 -5.3 0 -5 -5.5 11/11/2005 18:50:00 1.5 0.5 2.3 0.4 1.3 0.5 2.6 0.4 1.1 0.6 2.3 0.4 95 12 72 300 -5.5 0 -5.5 -5.7 11/11/2005 19:00:00 1 0.5 2.3 0.4 0.8 0.5 2.3 0.4 0.7 0.3 1.5 0.4 144 27 97 300 -5.8 0.1 -5.5 -6.1 11/11/2005 19:10:00 0.6 0.4 2.6 0.4 0.5 0.4 1.9 0.4 0.5 0.2 1.5 0.4 147 64 123 300 -6 0 -5.7 -6.1 11/11/2005 19:20:00 0.9 0.9 4.6 0.4 0.8 0.8 4.6 0.4 0.6 0.5 3 0.4 90 30 52 300 -5.9 0 -5.7 -6.1 11/11/2005 19:30:00 1.3 0.8 4.2 0.4 1.2 0.8 3.8 0.4 1 0.5 3 0.4 126 35 66 300 -5.7 0.1 -5.5 -5.9 11/11/2005 19:40:00 1.9 0.8 4.6 0.7 1.8 0.8 4.9 0.4 1.5 0.7 4.6 0.4 85 29 98 300 -5.6 0 -5.5 -5.7 11/11/2005 19:50:00 1 0.5 2.6 0.4 0.9 0.5 2.3 0.4 0.8 0.4 1.9 0.4 112 35 83 300 -5.6 0 -5.5 -5.7 11/11/2005 20:00:00 0.7 0.5 2.6 0.4 0.6 0.5 2.6 0.4 0.4 0.2 1.1 0.4 110 27 90 300 -5.5 0 -5.5 -5.7 11/11/2005 20:10:00 0.4 0.2 1.9 0.4 0.4 0.1 1.5 0.4 0.4 0 0.7 0.4 88 16 103 300 -5.8 0 -5.7 -5.9 11/11/2005 20:20:00 0.5 0.3 1.9 0.4 0.4 0.2 1.5 0.4 0.5 0.3 1.1 0.4 133 36 48 300 -5.7 0.2 -5.5 -5.9 11/11/2005 20:30:00 0.4 0.2 1.1 0.4 0.4 0.1 1.1 0.4 0.8 0.2 1.1 0.4 156 15 156 300 -5.4 0 -5.5 -5.7 11/11/2005 20:40:00 0.9 0.2 1.5 0.4 0.6 0.2 1.1 0.4 0.8 0.2 1.1 0.4 168 0 169 300 -6 0.2 -5.5 -6.4 11/11/2005 20:50:00 0.9 0.3 1.9 0.4 0.6 0.3 1.5 0.4 0.8 0.3 1.5 0.4 178 4 179 300 -6.2 0 -6.1 -6.4 11/11/2005 21:00:00 0.5 0.2 1.1 0.4 0.4 0.1 1.1 0.4 0.4 0.1 0.7 0.4 178 0 178 300 -6.6 0 -6.1 -6.8 11/11/2005 21:10:00 0.4 0.1 1.1 0.4 0.4 0.1 0.7 0.4 0.4 0 0.4 0.4 178 0 178 300 -6.5 0 -6.4 -6.8 11/11/2005 21:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 184 6 300 300 -6.5 0 -6.1 -6.6 11/11/2005 21:30:00 0.5 0.4 1.9 0.4 0.5 0.3 1.9 0.4 0.4 0.2 1.5 0.4 100 90 35 300 -6.6 0.1 -6.1 -6.8 11/11/2005 21:40:00 1.6 0.5 3 0.4 1.4 0.5 2.6 0.4 0.9 0.4 2.3 0.4 60 16 76 300 -6.5 0 -6.4 -6.6 11/11/2005 21:50:00 0.7 0.4 2.3 0.4 0.5 0.3 1.5 0.4 0.7 0.3 1.1 0.4 140 22 66 300 -6.5 0 -6.4 -6.8 11/11/2005 22:00:00 0.4 0 0.7 0.4 0.4 0 0.4 0.4 0.4 0.1 0.7 0.4 150 0 150 300 -6.9 0.1 -6.6 -7 11/11/2005 22:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0.1 0.7 0.4 150 0 300 300 -6.9 0.1 -6.6 -7 11/11/2005 22:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 150 0 300 300 -6.8 0 -6.6 -7 11/11/2005 22:30:00 0.7 0.5 2.6 0.4 0.5 0.4 2.3 0.4 0.4 0.2 1.5 0.4 117 21 103 300 -7.3 0.2 -6.8 -7.6 11/11/2005 22:40:00 1 0.5 2.3 0.4 0.8 0.5 2.3 0.4 0.7 0.3 1.5 0.4 105 5 97 300 -7.8 0.1 -7.6 -8.1 11/11/2005 22:50:00 2.1 0.4 3.4 1.1 1.9 0.4 3.4 1.1 1.3 0.4 2.6 0.4 89 8 98 300 -7.6 0 -7.6 -7.6 11/11/2005 23:00:00 1.3 0.5 2.6 0.4 1.1 0.5 2.3 0.4 1 0.4 2.3 0.4 109 18 75 300 -7.7 0.1 -7.4 -8.1 11/11/2005 23:10:00 1 0.5 2.3 0.4 0.8 0.5 2.3 0.4 0.9 0.4 1.9 0.4 130 11 109 300 -7.6 0 -7.2 -7.9 11/11/2005 23:20:00 1.2 0.4 1.9 0.4 1 0.4 1.9 0.4 1.3 0.4 2.3 0.4 144 20 156 300 -7.5 0.1 -7 -7.6 11/11/2005 23:30:00 1.8 0.5 3.4 0.4 1.7 0.6 3.4 0.4 1.4 0.4 2.3 0.4 139 17 125 300 -7.7 0.2 -7.2 -8.1 11/11/2005 23:40:00 1 0.6 2.6 0.4 0.9 0.6 2.3 0.4 0.7 0.6 2.3 0.4 134 22 103 300 -7.7 0.4 -7 -8.3 11/11/2005 23:50:00 0.7 0.4 2.6 0.4 0.5 0.3 1.9 0.4 0.4 0 0.7 0.4 130 17 109 300 -8.2 0.1 -8.1 -8.7 11/12/2005 00:00:00 1.6 0.5 3 0.4 1.4 0.6 2.6 0.4 0.9 0.4 2.3 0.4 108 17 107 300 -8.2 0.1 -7.6 -8.5 11/12/2005 00:10:00 2.2 0.7 4.9 1.1 2.1 0.7 5.3 1.1 1.7 0.7 4.6 0.4 111 16 71 300 -8.4 0.3 -7.9 -8.9 11/12/2005 00:20:00 2.1 0.7 4.2 0.7 1.9 0.7 4.2 0.7 1.4 0.6 3.4 0.4 118 18 67 300 -8.1 0.2 -7.4 -8.3 11/12/2005 00:30:00 1.7 0.5 3.4 0.4 1.5 0.5 3.4 0.4 0.9 0.4 1.9 0.4 114 14 116 300 -8.1 0.2 -7.6 -8.5 11/12/2005 00:40:00 2 0.5 3 0.7 1.8 0.5 3 0.4 1.1 0.5 2.3 0.4 78 13 77 300 -8.3 0.2 -8.1 -8.7 11/12/2005 00:50:00 2.7 0.5 4.2 1.5 2.6 0.5 4.2 1.5 1.9 0.5 3.4 0.7 64 8 57 300 -8.1 0 -7.9 -8.3 11/12/2005 01:00:00 3.2 0.7 4.9 1.9 3.2 0.7 5.3 1.5 2.5 0.6 4.2 1.1 60 10 57 300 -7.8 0.3 -7.2 -8.3 11/12/2005 01:10:00 3.9 0.7 5.3 2.3 3.9 0.7 5.3 1.9 2.9 0.6 4.6 1.5 54 8 64 300 -7.5 0 -7.2 -7.6 11/12/2005 01:20:00 2.3 0.6 4.2 0.7 2.1 0.6 3.8 0.7 1.7 0.5 3.8 0.7 78 12 62 300 -7.3 0.2 -7 -7.6 11/12/2005 01:30:00 2.3 0.4 4.2 1.1 2.2 0.5 4.2 0.7 1.8 0.3 2.6 1.1 88 12 67 300 -7.8 0 -7.4 -7.9 11/12/2005 01:40:00 2.7 0.6 4.9 1.1 2.6 0.6 5.3 1.1 2 0.5 3.8 0.4 88 15 87 300 -7.2 0.2 -6.8 -7.6 11/12/2005 01:50:00 3.8 1 6.5 1.9 3.8 1 6.5 1.5 3 1 6.1 0.7 70 13 60 300 -7.2 0 -7 -7.4 11/12/2005 02:00:00 4.3 0.9 6.5 2.3 4.2 0.9 6.8 2.3 3.4 1 6.1 1.5 64 12 69 300 -6.8 0.1 -6.6 -7 11/12/2005 02:10:00 3.5 0.9 6.8 1.9 3.5 0.9 6.5 1.5 2.8 0.7 5.3 1.5 73 13 55 300 -6.5 0.1 -6.1 -6.8 11/12/2005 02:20:00 2.6 0.6 4.9 0.7 2.5 0.6 4.6 0.4 2.1 0.5 3.8 0.4 93 17 77 300 -6.9 0.3 -6.1 -7.4 11/12/2005 02:30:00 1.3 0.6 3 0.4 1.2 0.6 3.4 0.4 1 0.5 2.3 0.4 115 29 90 300 -7.8 0.2 -7.2 -8.1 11/12/2005 02:40:00 1.4 0.5 2.3 0.4 1.2 0.5 1.9 0.4 1 0.4 1.9 0.4 158 17 167 300 -8.1 0 -7.9 -8.1 11/12/2005 02:50:00 1.1 0.3 1.9 0.4 0.9 0.3 1.9 0.4 0.9 0.4 1.9 0.4 159 17 125 300 -8.4 0.2 -8.1 -8.7 11/12/2005 03:00:00 1.1 0.3 1.5 0.4 0.9 0.3 1.5 0.4 0.8 0.4 1.5 0.4 153 10 160 300 -8.7 0 -8.5 -8.7 11/12/2005 03:10:00 1.1 0.3 1.9 0.4 0.9 0.3 1.5 0.4 0.8 0.3 1.5 0.4 120 21 146 300 -8.9 0 -8.7 -8.9 11/12/2005 03:20:00 1.4 0.3 1.9 0.7 1.2 0.3 1.9 0.4 1.3 0.3 1.9 0.7 108 12 122 300 -8.9 0 -8.5 -8.9 11/12/2005 03:30:00 1.7 0.2 2.3 1.1 1.5 0.2 1.9 1.1 1.7 0.2 2.3 1.1 125 3 128 300 -8.7 0.1 -8.5 -8.9 11/12/2005 03:40:00 1.9 0.2 2.3 1.5 1.7 0.2 2.3 1.1 1.6 0.2 1.9 1.1 118 6 122 300 -8.9 0 -8.7 -9.1 11/12/2005 03:50:00 1.7 0.3 2.3 1.1 1.4 0.3 2.3 0.7 1.6 0.2 2.3 1.1 113 6 115 300 -9.1 0.2 -8.7 -9.5 11/12/2005 04:00:00 1.2 0.3 1.9 0.4 0.9 0.3 1.5 0.4 1.2 0.3 1.9 0.4 116 6 111 300 -9 0.2 -8.5 -9.3 11/12/2005 04:10:00 1.4 0.3 1.9 0.7 1.2 0.3 1.9 0.7 1.2 0.3 1.9 0.4 136 10 131 300 -8.9 0.1 -8.5 -9.1 11/12/2005 04:20:00 1 0.4 1.5 0.4 0.8 0.3 1.5 0.4 1 0.2 1.5 0.4 139 11 147 300 -9.2 0.1 -8.9 -9.3 11/12/2005 04:30:00 1.2 0.3 1.9 0.4 1.1 0.3 1.5 0.4 1.1 0.3 1.5 0.4 153 5 156 300 -9.1 0.2 -8.7 -9.3 11/12/2005 04:40:00 1.2 0.4 1.9 0.4 1 0.4 1.9 0.4 0.8 0.5 1.5 0.4 138 13 155 300 -9.6 0.2 -9.3 -10 11/12/2005 04:50:00 0.5 0.2 1.1 0.4 0.4 0.2 1.1 0.4 0.4 0.1 0.7 0.4 128 10 122 300 -9.4 0.2 -9.1 -9.7 11/12/2005 05:00:00 0.4 0.1 0.7 0.4 0.4 0.1 0.7 0.4 0.4 0 0.4 0.4 162 9 155 300 -9.2 0 -8.9 -9.3 11/12/2005 05:10:00 0.4 0.1 1.1 0.4 0.4 0.1 0.7 0.4 0.4 0.1 1.1 0.4 134 24 139 300 -9.3 0.2 -8.9 -9.7 11/12/2005 05:20:00 0.9 0.4 1.9 0.4 0.8 0.4 1.9 0.4 0.8 0.3 1.5 0.4 151 22 161 300 -9.7 0 -9.5 -10 11/12/2005 05:30:00 1.4 0.2 1.9 1.1 1.2 0.2 1.9 0.7 1 0.3 1.5 0.4 171 6 178 300 -9.7 0 -9.5 -9.7 11/12/2005 05:40:00 0.6 0.3 1.1 0.4 0.5 0.2 1.1 0.4 0.6 0.2 1.1 0.4 171 6 178 300 -9.7 0 -9.5 -9.7 11/12/2005 05:50:00 1.1 0.5 1.9 0.4 1 0.5 1.9 0.4 0.9 0.4 1.5 0.4 160 8 150 300 -9.5 0.1 -9.1 -9.7 11/12/2005 06:00:00 1.6 0.2 1.9 1.1 1.5 0.2 1.9 1.1 1.1 0.2 1.5 0.4 145 5 136 300 -9.5 0.3 -8.9 -10.2 11/12/2005 06:10:00 1 0.4 1.9 0.4 0.9 0.4 1.5 0.4 0.5 0.2 1.1 0.4 155 4 156 300 -9.8 0.1 -9.3 -10.2 11/12/2005 06:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 171 6 300 300 -9.3 0 -9.1 -9.3 11/12/2005 06:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.7 0.4 173 0 300 300 -9.4 0 -9.3 -9.7 11/12/2005 06:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.5 0.2 1.1 0.4 149 7 300 300 -10.1 0.2 -9.5 -10.6 11/12/2005 06:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.6 0.2 1.1 0.4 146 0 300 300 -10.5 0 -10.4 -10.6 11/12/2005 07:00:00 0.4 0.1 1.1 0.4 0.4 0.1 0.7 0.4 0.9 0.3 1.5 0.4 128 17 106 300 -10.5 0 -10.2 -10.6 11/12/2005 07:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.7 0.3 1.5 0.4 106 0 300 300 -10.8 0.1 -10.6 -11 11/12/2005 07:20:00 0.4 0 0.7 0.4 0.4 0 0.4 0.4 0.8 0.2 1.1 0.4 102 2 103 300 -10.5 0 -10.4 -10.6 11/12/2005 07:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.9 0.3 1.9 0.4 100 0 300 300 -10.6 0.1 -10.4 -10.8 11/12/2005 07:40:00 0.7 0.4 1.5 0.4 0.6 0.3 1.5 0.4 1 0.2 1.5 0.4 103 5 99 300 -10.4 0 -10.2 -10.6 11/12/2005 07:50:00 0.6 0.3 1.1 0.4 0.5 0.2 1.1 0.4 1.2 0.2 1.5 0.7 109 2 110 300 -10.7 0.2 -10.4 -11 11/12/2005 08:00:00 0.6 0.2 1.1 0.4 0.4 0.2 1.1 0.4 1.2 0.2 1.9 0.7 98 2 102 300 -10.9 0 -10.6 -11.2 11/12/2005 08:10:00 0.4 0.1 0.7 0.4 0.4 0 0.7 0.4 0.9 0.2 1.5 0.4 98 0 98 300 -10.6 0.4 -10.2 -11.2 11/12/2005 08:20:00 0.4 0.1 1.1 0.4 0.4 0.1 1.1 0.4 0.7 0.2 1.1 0.4 98 0 98 300 -10.3 0.2 -9.7 -10.6 11/12/2005 08:30:00 1 0.2 1.5 0.4 0.9 0.3 1.5 0.4 0.7 0.2 1.1 0.4 119 8 122 300 -10.4 0 -10.2 -10.6 11/12/2005 08:40:00 0.9 0.2 1.5 0.4 0.8 0.2 1.1 0.4 0.6 0.2 1.1 0.4 129 2 128 300 -10.4 0 -10.2 -10.6 11/12/2005 08:50:00 1 0.2 1.5 0.7 0.9 0.2 1.1 0.7 0.7 0.2 1.1 0.4 138 3 134 300 -10.5 0 -10.4 -10.6 11/12/2005 09:00:00 0.8 0.2 1.1 0.4 0.7 0.2 1.1 0.4 0.4 0.1 0.7 0.4 139 3 134 300 -10.4 0 -10.2 -10.6 11/12/2005 09:10:00 0.7 0.2 1.1 0.4 0.5 0.2 1.1 0.4 0.4 0 0.4 0.4 131 6 140 300 -10.5 0 -10.2 -10.8 11/12/2005 09:20:00 0.5 0.2 1.1 0.4 0.4 0.1 0.7 0.4 0.4 0 0.4 0.4 112 8 123 300 -11 0.1 -10.6 -11.4 11/12/2005 09:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 107 0 300 300 -10.6 0.2 -10.4 -11 11/12/2005 09:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0.1 0.7 0.4 107 3 300 300 -10.5 0 -10.2 -10.8 11/12/2005 09:50:00 0.4 0 0.7 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 111 18 125 300 -10.6 0.3 -10.2 -11 11/12/2005 10:00:00 0.4 0.1 0.7 0.4 0.4 0 0.7 0.4 0.4 0 0.4 0.4 113 19 107 300 -9.9 0.1 -9.7 -10.2 11/12/2005 10:10:00 0.4 0 0.7 0.4 0.4 0 0.7 0.4 0.4 0 0.4 0.4 141 0 141 300 -9.3 0.2 -8.9 -9.7 11/12/2005 10:20:00 0.4 0.1 1.1 0.4 0.4 0 0.7 0.4 0.4 0.1 1.1 0.4 151 9 166 300 -9 0.3 -8.1 -9.3 11/12/2005 10:30:00 0.4 0.1 1.1 0.4 0.4 0.1 0.7 0.4 0.4 0.1 0.7 0.4 139 30 166 300 -7.8 0.2 -7.4 -8.1 11/12/2005 10:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 91 1 300 300 -6.8 0.4 -6.1 -7.4 11/12/2005 10:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 173 11 300 300 -6.1 0 -5.9 -6.4 11/12/2005 11:00:00 0.4 0.1 0.7 0.4 0.4 0 0.7 0.4 0.4 0.1 0.7 0.4 179 4 175 300 -6.3 0.2 -5.9 -6.6 11/12/2005 11:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0.1 0.7 0.4 184 0 300 300 -6.5 0 -6.1 -6.6 11/12/2005 11:20:00 0.4 0.1 0.7 0.4 0.4 0 0.7 0.4 0.4 0 0.4 0.4 184 0 184 300 -6.2 0 -6.1 -6.4 11/12/2005 11:30:00 0.5 0.2 1.1 0.4 0.4 0.2 1.1 0.4 0.4 0 0.4 0.4 194 7 179 300 -6 0 -5.7 -6.1 11/12/2005 11:40:00 0.5 0.2 1.1 0.4 0.4 0.2 1.1 0.4 0.4 0 0.4 0.4 200 7 205 300 -6 0 -5.9 -6.1 11/12/2005 11:50:00 0.5 0.3 1.5 0.4 0.5 0.3 1.5 0.4 0.4 0 0.4 0.4 197 8 190 300 -6 0 -5.9 -6.1 11/12/2005 12:00:00 0.4 0.1 1.1 0.4 0.4 0.1 0.7 0.4 0.4 0 0.4 0.4 216 0 216 300 -6 0.1 -5.5 -6.1 11/12/2005 12:10:00 0.7 0.3 1.1 0.4 0.6 0.2 1.1 0.4 0.4 0 0.4 0.4 230 10 237 300 -4.8 0.3 -4.4 -5.5 11/12/2005 12:20:00 0.8 0.4 1.5 0.4 0.7 0.3 1.5 0.4 0.4 0 0.4 0.4 224 5 230 300 -4.2 0.2 -3.7 -4.6 11/12/2005 12:30:00 0.6 0.3 1.5 0.4 0.5 0.2 1.1 0.4 0.4 0 0.4 0.4 211 11 219 300 -3.9 0 -3.7 -4.2 11/12/2005 12:40:00 0.7 0.3 1.5 0.4 0.7 0.3 1.1 0.4 0.4 0 0.4 0.4 195 14 214 300 -4.2 0 -3.9 -4.4 11/12/2005 12:50:00 0.5 0.2 1.5 0.4 0.5 0.2 1.1 0.4 0.4 0 0.4 0.4 205 8 194 300 -4.2 0 -3.9 -4.4 11/12/2005 13:00:00 0.6 0.2 1.1 0.4 0.5 0.2 1.1 0.4 0.4 0 0.4 0.4 190 6 193 300 -4.2 0 -3.9 -4.4 11/12/2005 13:10:00 0.4 0.2 1.1 0.4 0.4 0.2 1.1 0.4 0.4 0 0.4 0.4 210 6 212 300 -4.2 0 -3.9 -4.4 11/12/2005 13:20:00 0.6 0.3 1.5 0.4 0.5 0.2 1.1 0.4 0.6 0.2 1.1 0.4 228 5 237 300 -4 0 -3.9 -4.4 11/12/2005 13:30:00 0.5 0.3 1.5 0.4 0.4 0.2 1.1 0.4 0.6 0.3 1.5 0.4 236 2 233 300 -3.9 0 -3.7 -3.9 11/12/2005 13:40:00 0.7 0.3 1.5 0.4 0.6 0.3 1.5 0.4 0.9 0.3 1.5 0.4 227 6 233 300 -3.6 0.1 -3.3 -3.9 11/12/2005 13:50:00 0.9 0.4 1.9 0.4 0.9 0.4 1.9 0.4 1 0.4 1.9 0.4 201 13 160 300 -3.3 0 -3 -3.5 11/12/2005 14:00:00 1.5 0.4 2.3 0.4 1.4 0.4 2.3 0.4 1.5 0.3 2.3 0.7 189 7 194 300 -3.6 0 -3.5 -3.7 11/12/2005 14:10:00 1.6 0.4 2.3 0.7 1.6 0.3 2.3 0.7 1.7 0.4 2.3 0.7 196 10 171 300 -3.7 0 -3.5 -3.7 11/12/2005 14:20:00 1.2 0.3 2.3 0.4 1.2 0.3 2.3 0.4 1.3 0.3 1.9 0.4 206 10 195 300 -3.4 0 -3.3 -3.7 11/12/2005 14:30:00 1.1 0.4 2.3 0.4 1.1 0.4 1.9 0.4 1.3 0.3 1.9 0.4 211 12 203 300 -3.3 0 -3.3 -3.5 11/12/2005 14:40:00 1.1 0.4 2.3 0.4 1.1 0.4 2.3 0.4 1.4 0.4 2.3 0.4 211 13 239 300 -3.4 0 -3.3 -3.5 11/12/2005 14:50:00 1.1 0.3 1.9 0.4 1 0.3 1.5 0.4 1.1 0.4 2.3 0.4 221 6 226 300 -3.3 0.1 -2.8 -3.5 11/12/2005 15:00:00 0.7 0.3 1.9 0.4 0.6 0.3 1.5 0.4 0.8 0.3 1.5 0.4 207 11 218 300 -3.5 0 -3.5 -3.5 11/12/2005 15:10:00 0.6 0.3 1.5 0.4 0.5 0.2 1.5 0.4 0.7 0.3 1.5 0.4 192 6 174 300 -3.4 0 -3.3 -3.5 11/12/2005 15:20:00 0.6 0.3 1.5 0.4 0.6 0.3 1.5 0.4 0.6 0.3 1.5 0.4 196 9 183 300 -3.7 0 -3.3 -3.9 11/12/2005 15:30:00 0.5 0.3 1.5 0.4 0.5 0.2 1.1 0.4 0.5 0.2 1.1 0.4 205 4 215 300 -4 0 -3.9 -4.2 11/12/2005 15:40:00 0.5 0.2 1.5 0.4 0.6 0.2 1.1 0.4 0.6 0.2 1.1 0.4 206 3 205 300 -4.2 0.1 -3.9 -4.4 11/12/2005 15:50:00 0.5 0.2 1.1 0.4 0.4 0.1 0.7 0.4 0.4 0.1 0.7 0.4 221 4 224 300 -4.5 0.2 -4.4 -4.8 11/12/2005 16:00:00 0.4 0.2 0.7 0.4 0.4 0 0.4 0.4 0.6 0.3 1.1 0.4 218 8 223 300 -5 0.1 -4.8 -5.3 11/12/2005 16:10:00 0.8 0.2 1.1 0.4 0.6 0.2 1.1 0.4 0.8 0.2 1.1 0.4 183 7 189 300 -5.4 0 -5 -5.5 11/12/2005 16:20:00 0.9 0.3 1.5 0.4 0.7 0.3 1.1 0.4 0.9 0.2 1.5 0.4 163 17 178 300 -5.8 0 -5.5 -5.9 11/12/2005 16:30:00 0.5 0.2 1.1 0.4 0.4 0.2 1.1 0.4 1.1 0.4 1.9 0.4 103 17 99 300 -6.3 0.1 -5.9 -6.6 11/12/2005 16:40:00 0.5 0.3 1.1 0.4 0.4 0.2 1.1 0.4 1 0.3 1.9 0.4 73 4 80 300 -6.7 0.1 -6.4 -7 11/12/2005 16:50:00 0.6 0.3 1.5 0.4 0.5 0.2 1.5 0.4 0.8 0.3 1.5 0.4 72 0 72 300 -7.1 0 -6.8 -7.2 11/12/2005 17:00:00 0.4 0.2 1.1 0.4 0.4 0.1 1.1 0.4 0.9 0.2 1.5 0.4 72 0 72 300 -7.4 0.1 -7.2 -7.4 11/12/2005 17:10:00 0.6 0.4 1.5 0.4 0.5 0.3 1.5 0.4 1.2 0.3 1.9 0.4 72 2 72 300 -7.5 0 -7.4 -7.6 11/12/2005 17:20:00 0.7 0.3 1.5 0.4 0.6 0.3 1.5 0.4 1.2 0.3 1.9 0.4 76 0 76 300 -7.6 0 -7.4 -7.9 11/12/2005 17:30:00 0.4 0 0.7 0.4 0.4 0 0.4 0.4 0.6 0.3 1.5 0.4 64 15 51 300 -7.9 0.1 -7.6 -8.1 11/12/2005 17:40:00 0.8 0.4 1.5 0.4 0.6 0.3 1.5 0.4 0.7 0.2 1.1 0.4 64 21 92 300 -8 0 -7.6 -8.3 11/12/2005 17:50:00 1.1 0.2 1.5 0.7 0.8 0.2 1.1 0.4 0.9 0.2 1.1 0.4 87 5 92 300 -8.5 0.1 -8.1 -8.7 11/12/2005 18:00:00 1 0.2 1.1 0.7 0.8 0.2 1.1 0.4 0.9 0.2 1.5 0.4 88 9 75 300 -8.8 0.1 -8.5 -9.1 11/12/2005 18:10:00 1.1 0.3 1.5 0.4 0.9 0.3 1.5 0.4 1 0.3 1.5 0.4 104 7 97 300 -9.1 0 -8.9 -9.1 11/12/2005 18:20:00 0.8 0.3 1.5 0.4 0.6 0.3 1.1 0.4 0.5 0.2 1.1 0.4 106 8 114 300 -9.2 0 -8.9 -9.3 11/12/2005 18:30:00 0.6 0.2 1.1 0.4 0.4 0.2 1.1 0.4 0.6 0.2 1.1 0.4 86 5 97 300 -9 0.1 -8.7 -9.3 11/12/2005 18:40:00 1.1 0.3 1.9 0.4 0.9 0.3 1.9 0.4 0.7 0.2 1.1 0.4 89 8 88 300 -9.5 0.2 -9.1 -9.7 11/12/2005 18:50:00 1.2 0.2 1.5 0.7 1 0.2 1.5 0.4 1.1 0.2 1.5 0.7 87 7 96 300 -9.7 0 -9.7 -9.7 11/12/2005 19:00:00 1.1 0.2 1.5 0.7 0.9 0.2 1.5 0.4 1 0.2 1.5 0.7 105 5 91 300 -10 0.2 -9.7 -10.4 11/12/2005 19:10:00 0.6 0.2 1.1 0.4 0.4 0.1 0.7 0.4 0.8 0.2 1.5 0.4 103 3 106 300 -10.4 0 -10.2 -10.6 11/12/2005 19:20:00 0.4 0.1 0.7 0.4 0.4 0 0.7 0.4 0.6 0.2 1.1 0.4 87 5 86 300 -10 0 -9.7 -10.2 11/12/2005 19:30:00 0.5 0.2 1.1 0.4 0.4 0.1 0.7 0.4 0.5 0.2 0.7 0.4 86 0 86 300 -10.3 0.1 -10 -10.6 11/12/2005 19:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0.1 0.7 0.4 86 0 300 300 -10.6 0 -10.4 -10.8 11/12/2005 19:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.7 0.4 86 0 300 300 -10.7 0.2 -10.4 -11 11/12/2005 20:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.5 0.2 1.1 0.4 86 0 300 300 -10.9 0 -10.6 -11.2 11/12/2005 20:10:00 0.7 0.3 1.1 0.4 0.5 0.2 1.1 0.4 0.9 0.2 1.5 0.4 73 7 80 300 -10.8 0.3 -10.4 -11.2 11/12/2005 20:20:00 0.9 0.4 1.9 0.4 0.8 0.4 1.9 0.4 1.3 0.2 1.9 0.7 60 2 59 300 -10.4 0 -10.4 -10.6 11/12/2005 20:30:00 0.6 0.2 1.1 0.4 0.4 0.2 1.1 0.4 1 0.2 1.5 0.4 67 7 59 300 -10.6 0.1 -10.4 -11 11/12/2005 20:40:00 0.5 0.3 1.5 0.4 0.4 0.2 1.5 0.4 1 0.3 1.5 0.4 73 3 77 300 -10.7 0.3 -10.2 -11.2 11/12/2005 20:50:00 1.4 0.3 2.3 0.7 1.3 0.3 1.9 0.4 1 0.2 1.5 0.4 59 6 57 300 -9.8 0.1 -9.7 -10.2 11/12/2005 21:00:00 1 0.3 1.5 0.4 0.9 0.3 1.5 0.4 0.8 0.4 1.5 0.4 60 0 64 300 -10.5 0.4 -9.7 -11 11/12/2005 21:10:00 0.7 0.3 1.5 0.4 0.6 0.3 1.1 0.4 0.6 0.2 1.1 0.4 65 7 77 300 -10.6 0.1 -10.4 -11 11/12/2005 21:20:00 0.4 0.2 1.1 0.4 0.4 0.1 0.7 0.4 0.4 0.1 0.7 0.4 76 0 76 300 -11.3 0.2 -10.8 -11.6 11/12/2005 21:30:00 0.4 0.1 0.7 0.4 0.4 0 0.4 0.4 0.4 0.1 0.7 0.4 106 22 124 300 -11.1 0 -11 -11.4 11/12/2005 21:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 124 0 300 300 -11.6 0.1 -11.4 -11.8 11/12/2005 21:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 124 0 300 300 -11.7 0.1 -11.4 -11.8 11/12/2005 22:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 124 0 300 300 -11.3 0.1 -11 -11.4 11/12/2005 22:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 124 0 300 300 -11.6 0.1 -11.2 -11.8 11/12/2005 22:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0.1 0.7 0.4 124 0 300 300 -12 0.2 -11.4 -12.2 11/12/2005 22:30:00 0.8 0.4 1.5 0.4 0.7 0.3 1.1 0.4 0.8 0.3 1.5 0.4 104 17 105 300 -12.2 0.3 -11.4 -12.4 11/12/2005 22:40:00 1.5 0.2 1.9 1.1 1.3 0.2 1.9 1.1 1.3 0.2 1.9 0.7 79 9 76 300 -11.3 0.4 -10.8 -12.2 11/12/2005 22:50:00 1.4 0.3 1.9 0.7 1.2 0.3 1.9 0.7 1.6 0.2 2.3 1.1 89 5 91 300 -11.5 0.2 -11.2 -12 11/12/2005 23:00:00 1.1 0.3 1.5 0.4 0.9 0.3 1.9 0.4 1.1 0.3 1.9 0.4 82 6 83 300 -11.4 0.4 -11 -12.2 11/12/2005 23:10:00 0.4 0 0.7 0.4 0.4 0 0.4 0.4 0.4 0.1 0.7 0.4 76 0 76 300 -10.8 0.2 -10.6 -11.4 11/12/2005 23:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.7 0.4 76 0 300 300 -11.5 0 -11.2 -11.6 11/12/2005 23:30:00 0.4 0 0.7 0.4 0.4 0 0.4 0.4 0.4 0.1 0.7 0.4 91 6 77 300 -11.9 0.2 -11.4 -12.2 11/12/2005 23:40:00 0.4 0.1 0.7 0.4 0.4 0 0.4 0.4 0.4 0.1 0.7 0.4 118 12 124 300 -11.9 0.1 -11.6 -12.2 11/12/2005 23:50:00 0.5 0.2 1.1 0.4 0.4 0.1 0.7 0.4 0.4 0 0.7 0.4 117 13 124 300 -12.4 0.3 -12 -13 11/13/2005 00:00:00 0.8 0.3 1.5 0.4 0.6 0.3 1.5 0.4 1.1 0.4 1.9 0.4 75 12 62 300 -12.5 0.3 -11.8 -13 11/13/2005 00:10:00 1.1 0.2 1.9 0.7 0.9 0.2 1.5 0.7 1.7 0.2 2.3 1.1 68 3 62 300 -11.6 0.3 -11 -12 11/13/2005 00:20:00 1.3 0.2 1.9 0.7 1.1 0.2 1.5 0.4 1.8 0.3 2.3 1.1 64 8 58 300 -10.3 0.3 -9.7 -11 11/13/2005 00:30:00 1.6 0.2 1.9 1.1 1.5 0.2 1.9 0.7 1.9 0.2 2.3 1.5 83 7 71 300 -9.9 0.3 -9.5 -10.8 11/13/2005 00:40:00 1.5 0.2 1.9 1.1 1.4 0.2 1.9 0.7 1.8 0.2 2.3 1.5 89 3 80 300 -10.9 0 -10.6 -11 11/13/2005 00:50:00 1.2 0.2 1.5 0.7 1 0.2 1.5 0.4 1.7 0.2 2.3 1.1 83 3 80 300 -10.2 0.2 -9.7 -10.6 11/13/2005 01:00:00 1.1 0.2 1.5 0.7 0.9 0.2 1.5 0.4 1.8 0.2 2.3 1.1 88 4 87 300 -10.1 0.3 -9.7 -10.8 11/13/2005 01:10:00 1.1 0.3 1.9 0.4 0.9 0.3 1.5 0.4 1.5 0.3 2.3 0.4 102 8 82 300 -11.3 0.4 -10.6 -12 11/13/2005 01:20:00 0.6 0.4 1.5 0.4 0.5 0.3 1.5 0.4 0.5 0.3 1.5 0.4 104 7 96 300 -11.8 0.2 -11.4 -12.2 11/13/2005 01:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 112 0 300 300 -11.6 0.2 -11.4 -12.2 11/13/2005 01:40:00 0.9 0.4 1.5 0.4 0.8 0.4 1.5 0.4 0.8 0.4 1.5 0.4 63 12 62 300 -12.3 0.2 -12 -12.6 11/13/2005 01:50:00 1.1 0.3 1.9 0.4 1 0.3 1.9 0.4 1.6 0.2 1.9 1.1 75 8 75 300 -12.1 0.1 -11.8 -12.4 11/13/2005 02:00:00 0.6 0.3 1.5 0.4 0.6 0.2 1.1 0.4 1.4 0.3 1.9 0.7 83 0 83 300 -11.1 0.2 -10.8 -11.8 11/13/2005 02:10:00 0.4 0 0.7 0.4 0.4 0 0.7 0.4 0.7 0.3 1.5 0.4 79 8 63 300 -11.1 0.2 -10.8 -11.6 11/13/2005 02:20:00 0.4 0.2 1.1 0.4 0.4 0.1 1.1 0.4 0.5 0.2 1.1 0.4 89 28 125 300 -12.1 0.3 -11.4 -12.6 11/13/2005 02:30:00 0.6 0.3 1.5 0.4 0.5 0.2 1.1 0.4 0.5 0.2 1.1 0.4 117 6 121 300 -12.6 0.2 -12.2 -13 11/13/2005 02:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.9 0.2 1.5 0.4 105 0 300 300 -11.8 0.2 -11.4 -12.2 11/13/2005 02:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 1.4 0.2 1.9 1.1 105 0 300 300 -12.1 0.2 -11.6 -12.4 11/13/2005 03:00:00 0.4 0.1 1.1 0.4 0.4 0.1 0.7 0.4 1.5 0.3 2.3 0.7 95 7 81 300 -11.9 0.3 -11.4 -12.4 11/13/2005 03:10:00 1 0.4 1.9 0.4 0.9 0.4 1.5 0.4 2 0.2 2.6 1.5 77 5 74 300 -11.8 0.3 -11 -12.4 11/13/2005 03:20:00 1.4 0.2 1.9 0.7 1.2 0.3 1.9 0.7 1.8 0.3 2.3 1.1 72 3 74 300 -12 0.2 -11.4 -12.4 11/13/2005 03:30:00 1.5 0.3 1.9 1.1 1.3 0.3 1.9 0.7 0.9 0.4 1.9 0.4 76 4 76 300 -12.2 0 -12 -12.4 11/13/2005 03:40:00 1.1 0.2 1.9 0.7 0.9 0.2 1.5 0.4 1.2 0.3 1.9 0.4 94 13 86 300 -12.6 0.3 -11.8 -13 11/13/2005 03:50:00 0.8 0.2 1.1 0.4 0.6 0.2 1.1 0.4 0.6 0.2 1.1 0.4 111 6 108 300 -12.2 0.1 -12 -12.4 11/13/2005 04:00:00 0.5 0.2 1.1 0.4 0.4 0.1 0.7 0.4 1.1 0.3 1.5 0.4 104 3 105 300 -12.1 0.2 -11.8 -12.6 11/13/2005 04:10:00 0.8 0.4 1.5 0.4 0.7 0.3 1.1 0.4 1.4 0.2 1.9 0.7 73 16 61 300 -11.8 0.1 -11.4 -12.2 11/13/2005 04:20:00 1.1 0.2 1.5 0.7 0.9 0.2 1.5 0.4 1.4 0.2 1.9 0.7 62 2 61 300 -11.6 0.2 -11.2 -11.8 11/13/2005 04:30:00 0.8 0.3 1.5 0.4 0.6 0.3 1.1 0.4 1.1 0.3 1.9 0.4 79 12 65 300 -11.6 0.2 -11 -11.8 11/13/2005 04:40:00 0.5 0.2 1.1 0.4 0.4 0.1 0.7 0.4 0.4 0.1 0.7 0.4 107 8 111 300 -10.9 0 -10.6 -11.2 11/13/2005 04:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 113 0 300 300 -10.5 0.1 -10.2 -10.8 11/13/2005 05:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 113 0 300 300 -9.9 0 -9.7 -10.2 11/13/2005 05:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 113 0 300 300 -10.2 0 -10.2 -10.4 11/13/2005 05:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 113 0 300 300 -9.8 0.2 -9.5 -10.2 11/13/2005 05:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 113 0 300 300 -9.7 0 -9.5 -9.7 11/13/2005 05:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 113 0 300 300 -9.7 0 -9.5 -9.7 11/13/2005 05:50:00 0.4 0.1 1.1 0.4 0.4 0.1 0.7 0.4 0.4 0 0.4 0.4 113 1 113 300 -9.3 0.2 -8.9 -9.7 11/13/2005 06:00:00 0.4 0.2 1.1 0.4 0.4 0.1 0.7 0.4 0.4 0 0.4 0.4 126 0 124 300 -8.8 0 -8.7 -9.3 11/13/2005 06:10:00 0.7 0.3 1.5 0.4 0.6 0.3 1.5 0.4 0.4 0.2 1.1 0.4 106 14 109 300 -8.9 0 -8.7 -8.9 11/13/2005 06:20:00 0.6 0.3 1.1 0.4 0.5 0.2 1.1 0.4 0.4 0.2 1.1 0.4 84 5 86 300 -9 0 -8.9 -9.1 11/13/2005 06:30:00 0.4 0.2 1.1 0.4 0.4 0.1 0.7 0.4 0.4 0 0.7 0.4 67 10 68 300 -8.8 0 -8.7 -8.9 11/13/2005 06:40:00 0.8 0.3 1.1 0.4 0.6 0.2 1.1 0.4 0.4 0 0.4 0.4 108 9 103 300 -8.6 0 -8.5 -8.7 11/13/2005 06:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 108 0 300 300 -8.8 0 -8.5 -8.9 11/13/2005 07:00:00 0.5 0.2 1.1 0.4 0.4 0.1 0.7 0.4 0.4 0.1 0.7 0.4 103 1 103 300 -8.6 0 -8.5 -8.7 11/13/2005 07:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 139 27 300 300 -8.5 0 -8.3 -8.7 11/13/2005 07:20:00 0.4 0.1 0.7 0.4 0.4 0 0.4 0.4 0.4 0 0.7 0.4 179 0 179 300 -8.4 0 -8.1 -8.5 11/13/2005 07:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0.1 0.7 0.4 179 0 300 300 -8.3 0 -8.1 -8.3 11/13/2005 07:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.7 0.4 179 0 300 300 -8.3 0 -8.1 -8.5 11/13/2005 07:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 179 0 300 300 -8.3 0 -8.3 -8.5 11/13/2005 08:00:00 0.4 0 0.7 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 173 16 119 300 -8.6 0.1 -8.3 -8.9 11/13/2005 08:10:00 0.7 0.3 1.5 0.4 0.5 0.2 1.1 0.4 0.8 0.3 1.1 0.4 81 15 76 300 -9 0 -8.7 -8.9 11/13/2005 08:20:00 0.5 0.2 1.1 0.4 0.4 0.2 1.1 0.4 1 0.2 1.5 0.7 77 4 76 300 -9 0 -8.7 -9.1 11/13/2005 08:30:00 0.5 0.2 1.1 0.4 0.4 0.1 0.7 0.4 1.4 0.2 1.9 1.1 70 4 71 300 -8.9 0 -8.7 -8.9 11/13/2005 08:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 1.4 0.2 1.9 1.1 73 1 300 300 -8.6 0 -8.5 -8.7 11/13/2005 08:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 1.5 0.2 1.9 1.1 54 13 300 300 -8.5 0 -8.5 -8.7 11/13/2005 09:00:00 0.4 0.1 0.7 0.4 0.4 0 0.7 0.4 1.4 0.2 1.9 0.7 24 8 30 300 -8.4 0 -8.3 -8.5 11/13/2005 09:10:00 0.4 0 0.7 0.4 0.4 0 0.4 0.4 1.2 0.5 1.9 0.4 42 30 30 300 -8.3 0 -8.1 -8.5 11/13/2005 09:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.7 0.2 1.5 0.4 123 0 300 300 -8.6 0.1 -8.1 -8.9 11/13/2005 09:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 1 0.3 1.9 0.7 123 0 300 300 -8.4 0 -8.1 -8.7 11/13/2005 09:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.7 0.4 1.5 0.4 66 23 300 300 -8.3 0 -8.1 -8.5 11/13/2005 09:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.5 0.2 1.1 0.4 55 0 300 300 -8.2 0 -8.1 -8.5 11/13/2005 10:00:00 0.4 0 0.4 0.4 0.4 0.1 0.7 0.4 0.4 0 0.4 0.4 87 41 300 300 -8.2 0 -8.1 -8.5 11/13/2005 10:10:00 0.4 0 0.7 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 150 0 150 300 -7.9 0 -7.6 -8.1 11/13/2005 10:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 150 0 300 300 -7.8 0 -7.6 -7.9 11/13/2005 10:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 150 0 300 300 -7.4 0.1 -7 -7.6 11/13/2005 10:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 150 0 300 300 -7.1 0 -7 -7.2 11/13/2005 10:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 150 0 300 300 -7.1 0 -6.8 -7.2 11/13/2005 11:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 150 0 300 300 -6.7 0.2 -6.1 -7 11/13/2005 11:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 150 0 300 300 -6.1 0 -5.9 -6.4 11/13/2005 11:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 150 0 300 300 -5.9 0.1 -5.7 -6.1 11/13/2005 11:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 159 13 300 300 -5.7 0.1 -5.5 -5.9 11/13/2005 11:40:00 0.5 0.2 1.1 0.4 0.4 0.2 0.7 0.4 0.5 0.2 1.1 0.4 178 0 178 300 -6.4 0.1 -5.9 -6.6 11/13/2005 11:50:00 0.5 0.3 1.5 0.4 0.5 0.2 1.5 0.4 0.5 0.2 1.1 0.4 224 17 236 300 -5.5 0.2 -5.3 -6.1 11/13/2005 12:00:00 0.5 0.2 1.1 0.4 0.4 0.1 1.1 0.4 0.5 0.2 1.1 0.4 216 38 258 300 -5.7 0.2 -5.3 -6.1 11/13/2005 12:10:00 0.5 0.2 1.1 0.4 0.5 0.2 1.5 0.4 0.5 0.3 1.5 0.4 228 18 214 300 -6.1 0 -5.9 -6.4 11/13/2005 12:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.7 0.4 195 8 300 300 -5.8 0.1 -5.5 -5.9 11/13/2005 12:30:00 0.4 0.2 1.5 0.4 0.4 0.1 1.1 0.4 0.5 0.2 1.1 0.4 139 15 133 300 -5.7 0 -5.5 -5.7 11/13/2005 12:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 159 0 300 300 -5.8 0 -5.5 -5.9 11/13/2005 12:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 159 0 300 300 -5.6 0 -5.5 -5.7 11/13/2005 13:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 170 11 300 300 -5.4 0.2 -4.8 -5.7 11/13/2005 13:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 181 0 300 300 -4 0.4 -3.5 -4.8 11/13/2005 13:20:00 0.4 0 0.7 0.4 0.4 0 0.7 0.4 0.4 0.2 1.1 0.4 205 15 181 300 -4.1 0.2 -3.7 -4.4 11/13/2005 13:30:00 0.4 0 0.7 0.4 0.4 0 0.4 0.4 0.4 0.1 0.7 0.4 215 2 213 300 -4.4 0 -4.4 -4.6 11/13/2005 13:40:00 0.4 0.2 1.1 0.4 0.4 0.1 1.1 0.4 0.4 0.1 1.1 0.4 207 10 213 300 -4.1 0.2 -3.5 -4.4 11/13/2005 13:50:00 0.4 0.1 0.7 0.4 0.4 0.1 0.7 0.4 0.5 0.2 1.1 0.4 215 7 209 300 -3.5 0.1 -3.3 -3.7 11/13/2005 14:00:00 0.5 0.3 1.5 0.4 0.5 0.3 1.5 0.4 0.6 0.4 1.5 0.4 217 5 219 300 -3.7 0 -3.5 -3.9 11/13/2005 14:10:00 0.5 0.2 1.5 0.4 0.4 0.1 1.1 0.4 0.5 0.2 1.1 0.4 228 5 234 300 -4 0.1 -3.7 -4.4 11/13/2005 14:20:00 0.8 0.3 1.5 0.4 0.6 0.3 1.5 0.4 0.9 0.3 1.5 0.4 235 8 223 300 -4.2 0.1 -3.9 -4.4 11/13/2005 14:30:00 0.7 0.4 1.5 0.4 0.7 0.3 1.5 0.4 0.8 0.4 1.9 0.4 213 7 231 300 -4 0 -3.7 -4.2 11/13/2005 14:40:00 0.4 0.2 1.5 0.4 0.4 0.1 1.1 0.4 0.6 0.3 1.1 0.4 216 13 195 300 -3.9 0.1 -3.7 -4.2 11/13/2005 14:50:00 0.4 0.1 0.7 0.4 0.4 0.1 1.1 0.4 0.4 0.2 1.1 0.4 214 17 224 300 -3.5 0 -3.3 -3.9 11/13/2005 15:00:00 0.6 0.3 1.5 0.4 0.5 0.2 1.1 0.4 0.6 0.3 1.5 0.4 218 9 228 300 -4 0.3 -3.3 -4.4 11/13/2005 15:10:00 0.9 0.4 1.9 0.4 0.8 0.3 1.5 0.4 1 0.4 1.9 0.4 223 5 227 300 -4.5 0 -4.4 -4.6 11/13/2005 15:20:00 1.4 0.2 1.9 0.7 1.2 0.2 1.9 0.4 1.2 0.3 1.9 0.4 230 3 228 300 -4.8 0.1 -4.4 -5 11/13/2005 15:30:00 1.4 0.2 1.9 0.7 1.2 0.2 1.5 0.7 1.2 0.3 1.9 0.4 229 4 229 300 -5.2 0 -5 -5.5 11/13/2005 15:40:00 1.1 0.3 1.9 0.4 0.9 0.3 1.5 0.4 0.9 0.3 1.5 0.4 228 10 220 300 -5.6 0.1 -5.3 -5.7 11/13/2005 15:50:00 1.4 0.4 1.9 0.4 1.5 0.3 1.9 0.4 1.5 0.4 2.3 0.4 213 3 209 300 -5.9 0 -5.7 -6.1 11/13/2005 16:00:00 1.3 0.3 1.9 0.7 1.3 0.2 1.9 0.7 1.3 0.3 1.9 0.4 216 5 216 300 -6.2 0 -6.1 -6.4 11/13/2005 16:10:00 1.4 0.2 1.9 1.1 1.2 0.2 1.5 0.7 1.3 0.2 1.9 0.7 223 0 224 300 -6.5 0 -6.4 -6.6 11/13/2005 16:20:00 1 0.2 1.1 0.7 0.8 0.2 1.1 0.4 1.1 0.2 1.5 0.7 223 2 224 300 -6.6 0 -6.6 -6.8 11/13/2005 16:30:00 0.9 0.2 1.5 0.7 0.8 0.2 1.1 0.4 1 0.3 1.5 0.4 219 0 219 300 -7 0 -6.8 -7.2 11/13/2005 16:40:00 0.4 0.1 0.7 0.4 0.4 0 0.7 0.4 0.4 0.1 0.7 0.4 218 0 219 300 -7.4 0.2 -7 -7.6 11/13/2005 16:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 218 0 300 300 -7.7 0 -7.6 -7.9 11/13/2005 17:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.5 0.2 1.1 0.4 215 11 300 300 -8.1 0 -7.9 -8.5 11/13/2005 17:10:00 0.6 0.2 1.1 0.4 0.4 0.1 0.7 0.4 1.4 0.2 1.9 0.7 107 39 81 300 -8.4 0 -8.3 -8.5 11/13/2005 17:20:00 0.4 0.1 0.7 0.4 0.4 0 0.4 0.4 1.1 0.1 1.5 0.7 79 3 81 300 -8.7 0 -8.5 -8.9 11/13/2005 17:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 1 0.2 1.5 0.7 61 2 300 300 -9 0 -8.9 -9.1 11/13/2005 17:40:00 1.1 0.4 1.9 0.4 0.9 0.4 1.5 0.4 1.7 0.2 2.3 1.1 67 6 76 300 -9.3 0 -8.9 -9.3 11/13/2005 17:50:00 1.7 0.2 1.9 1.5 1.5 0.2 1.9 1.1 2.1 0.2 2.3 1.9 81 2 78 300 -9.7 0.1 -9.3 -10 11/13/2005 18:00:00 1.3 0.3 1.9 0.7 1 0.3 1.5 0.4 1.8 0.2 2.3 1.5 83 1 76 300 -9.4 0.2 -9.1 -10 11/13/2005 18:10:00 0.4 0.1 0.7 0.4 0.4 0 0.4 0.4 1.2 0.2 1.9 0.7 83 0 83 300 -9.7 0.1 -9.3 -9.7 11/13/2005 18:20:00 0.4 0.1 1.1 0.4 0.4 0.1 0.7 0.4 1.2 0.2 1.5 0.7 96 13 119 300 -10 0.3 -9.5 -10.6 11/13/2005 18:30:00 1.2 0.5 2.3 0.4 1 0.5 2.3 0.4 1.8 0.3 2.3 1.1 97 9 83 300 -10.6 0.1 -10.4 -11 11/13/2005 18:40:00 2.1 0.2 2.6 1.5 2 0.2 2.3 1.5 2.1 0.2 2.3 1.5 76 3 75 300 -10.7 0.1 -10.4 -11 11/13/2005 18:50:00 1.3 0.6 2.3 0.4 1.1 0.6 2.3 0.4 1.9 0.3 2.3 1.1 64 3 73 300 -9.8 0.3 -9.3 -10.4 11/13/2005 19:00:00 0.5 0.2 1.1 0.4 0.4 0.2 1.1 0.4 1.2 0.2 1.9 0.7 74 11 63 300 -10 0.2 -9.5 -10.6 11/13/2005 19:10:00 1 0.2 1.5 0.4 0.8 0.2 1.1 0.4 1.2 0.3 1.9 0.7 104 7 108 300 -11.2 0.2 -10.6 -11.4 11/13/2005 19:20:00 1.1 0.2 1.5 0.7 0.9 0.2 1.5 0.4 1.2 0.2 1.5 0.7 91 9 96 300 -11.3 0 -11 -11.4 11/13/2005 19:30:00 1.2 0.2 1.9 0.7 0.9 0.2 1.5 0.7 1.2 0.2 1.9 0.7 68 4 61 300 -11.2 0.2 -11 -11.4 11/13/2005 19:40:00 1 0.2 1.5 0.7 0.8 0.2 1.5 0.4 1.1 0.2 1.5 0.7 88 18 109 300 -11.5 0 -11.4 -11.6 11/13/2005 19:50:00 0.8 0.4 1.5 0.4 0.7 0.4 1.5 0.4 0.7 0.2 1.1 0.4 126 0 125 300 -11.6 0.1 -11.4 -11.8 11/13/2005 20:00:00 0.6 0.4 1.5 0.4 0.5 0.3 1.5 0.4 1.2 0.4 1.9 0.4 101 21 73 300 -11.6 0.2 -11.2 -11.8 11/13/2005 20:10:00 1.7 0.2 2.3 1.1 1.5 0.2 2.3 1.1 2 0.2 2.6 1.5 67 2 63 300 -11.2 0 -11 -11.4 11/13/2005 20:20:00 2.2 0.2 2.6 1.9 2.1 0.2 2.6 1.9 2.4 0.2 2.6 1.9 64 2 67 300 -10.6 0.2 -10.2 -11 11/13/2005 20:30:00 2.8 0.2 3.4 1.9 2.7 0.3 3 1.9 2.3 0.2 3 1.9 72 3 71 300 -10 0.2 -9.7 -10.6 11/13/2005 20:40:00 2.3 0.4 3 1.5 2.2 0.4 2.6 1.1 2.1 0.2 2.6 1.5 69 3 77 300 -9.5 0.2 -8.9 -9.7 11/13/2005 20:50:00 1.3 0.3 1.9 0.4 1.2 0.3 1.9 0.4 1.7 0.3 2.3 0.7 69 3 68 300 -9.5 0.5 -8.9 -11 11/13/2005 21:00:00 1.2 0.4 1.9 0.4 1 0.4 1.9 0.4 1.2 0.4 1.9 0.4 88 13 98 300 -11.3 0.2 -11 -11.6 11/13/2005 21:10:00 1.5 0.3 2.3 0.7 1.4 0.3 2.3 0.7 0.9 0.4 1.9 0.4 110 6 114 300 -11.8 0.2 -11.4 -12.2 11/13/2005 21:20:00 1.6 0.2 2.3 1.1 1.5 0.3 2.3 0.7 0.9 0.3 1.5 0.4 96 9 107 300 -12.3 0.2 -11.8 -12.6 11/13/2005 21:30:00 1.6 0.2 2.3 1.1 1.4 0.2 1.9 0.7 1.3 0.3 1.9 0.4 82 9 85 300 -12 0.2 -11.6 -12.6 11/13/2005 21:40:00 1.5 0.2 1.9 0.7 1.4 0.2 1.9 0.7 1 0.2 1.5 0.4 101 9 94 300 -11.8 0.1 -11.6 -12 11/13/2005 21:50:00 0.5 0.2 1.1 0.4 0.4 0.1 1.1 0.4 0.4 0.1 1.1 0.4 121 5 99 300 -12 0 -11.8 -12.2 11/13/2005 22:00:00 0.4 0.2 1.9 0.4 0.4 0.1 1.5 0.4 0.4 0 0.7 0.4 82 29 28 300 -11.6 0.1 -11.4 -11.8 11/13/2005 22:10:00 0.5 0.3 1.9 0.4 0.4 0.2 1.9 0.4 0.4 0.2 1.1 0.4 52 13 71 300 -11.7 0.2 -11.2 -11.8 11/13/2005 22:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 66 0 300 300 -11.6 0.1 -11.4 -11.8 11/13/2005 22:30:00 0.4 0.1 0.7 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 66 13 55 300 -12.2 0.2 -11.8 -12.6 11/13/2005 22:40:00 0.4 0.2 1.1 0.4 0.4 0.1 1.1 0.4 0.4 0 0.7 0.4 130 19 132 300 -12.4 0.1 -12.2 -12.6 11/13/2005 22:50:00 0.4 0 0.7 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 105 22 91 300 -12.5 0.1 -12.2 -12.6 11/13/2005 23:00:00 0.4 0 0.7 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 106 22 131 300 -12.1 0.2 -11.8 -12.6 11/13/2005 23:10:00 0.5 0.2 1.1 0.4 0.4 0.1 1.1 0.4 0.5 0.2 1.1 0.4 131 0 131 300 -12.4 0.2 -11.8 -12.6 11/13/2005 23:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 131 0 300 300 -12.8 0.1 -12.6 -13 11/13/2005 23:30:00 0.4 0.1 0.7 0.4 0.4 0.1 0.7 0.4 0.5 0.3 1.1 0.4 156 15 159 300 -12 0.3 -11.4 -12.6 11/13/2005 23:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0.1 0.7 0.4 142 47 300 300 -12.6 0.3 -12 -13.2 11/13/2005 23:50:00 0.4 0.1 0.7 0.4 0.4 0.1 0.7 0.4 0.4 0.1 0.7 0.4 50 11 43 300 -12.2 0.1 -11.8 -12.6 11/14/2005 00:00:00 0.8 0.3 1.5 0.4 0.7 0.3 1.1 0.4 0.6 0.2 1.1 0.4 99 12 109 300 -12.7 0.2 -12.4 -13.2 11/14/2005 00:10:00 0.7 0.3 1.5 0.4 0.6 0.3 1.5 0.4 0.4 0.2 0.7 0.4 120 7 128 300 -12.9 0.2 -12.4 -13.2 11/14/2005 00:20:00 0.5 0.2 1.1 0.4 0.4 0.1 1.1 0.4 0.4 0 0.4 0.4 118 15 128 300 -12.8 0.5 -12.2 -13.6 11/14/2005 00:30:00 0.4 0.2 1.1 0.4 0.4 0.1 1.1 0.4 0.4 0 0.4 0.4 81 5 79 300 -12.8 0.3 -12.6 -13.6 11/14/2005 00:40:00 1.2 0.5 3 0.4 1 0.5 3 0.4 0.6 0.4 2.3 0.4 98 21 54 300 -12.8 0.1 -12.6 -13.2 11/14/2005 00:50:00 0.4 0.2 1.1 0.4 0.4 0.1 1.1 0.4 0.4 0 0.4 0.4 101 15 114 300 -12.6 0.1 -12.2 -13 11/14/2005 01:00:00 1.1 0.5 2.3 0.4 0.9 0.5 2.3 0.4 0.4 0 0.7 0.4 96 22 51 300 -12.8 0.5 -12.2 -13.6 11/14/2005 01:10:00 0.8 0.5 2.3 0.4 0.7 0.4 1.9 0.4 0.4 0.2 1.1 0.4 95 19 52 300 -12.7 0.4 -12 -13.4 11/14/2005 01:20:00 1.2 0.3 1.9 0.4 1 0.4 1.9 0.4 0.5 0.2 1.1 0.4 70 11 75 300 -12.3 0.3 -11.8 -13.2 11/14/2005 01:30:00 1.1 0.3 1.9 0.4 0.9 0.3 1.5 0.4 0.4 0 0.4 0.4 71 8 75 300 -12.7 0.3 -12.2 -13.2 11/14/2005 01:40:00 0.4 0.2 1.1 0.4 0.4 0.1 0.7 0.4 0.4 0.1 0.7 0.4 133 24 91 300 -11.9 0.3 -11.4 -12.4 11/14/2005 01:50:00 0.5 0.2 1.1 0.4 0.4 0 0.7 0.4 1 0.3 1.5 0.4 213 17 212 300 -12 0 -11.8 -12.2 11/14/2005 02:00:00 0.4 0.1 0.7 0.4 0.4 0 0.7 0.4 1.1 0.2 1.5 0.7 232 9 222 300 -11.8 0 -11.8 -12 11/14/2005 02:10:00 0.8 0.4 1.5 0.4 0.7 0.3 1.5 0.4 0.7 0.3 1.5 0.4 224 4 230 300 -12.2 0.4 -11.8 -13.2 11/14/2005 02:20:00 0.6 0.3 1.5 0.4 0.5 0.3 1.5 0.4 0.6 0.4 1.5 0.4 207 15 201 300 -13.4 0.1 -13.2 -13.8 11/14/2005 02:30:00 0.4 0.1 0.7 0.4 0.4 0 0.4 0.4 0.4 0.1 0.7 0.4 201 5 203 300 -13.6 0 -13.4 -13.6 11/14/2005 02:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 159 43 300 300 -13.3 0.1 -13.2 -13.6 11/14/2005 02:50:00 0.8 0.4 1.5 0.4 0.6 0.3 1.1 0.4 0.6 0.3 1.1 0.4 77 12 98 300 -13.3 0 -13.2 -13.6 11/14/2005 03:00:00 1.4 0.2 1.9 0.7 1.2 0.2 1.9 0.7 1 0.2 1.5 0.4 103 4 103 300 -13.8 0.3 -13.2 -14 11/14/2005 03:10:00 0.6 0.3 1.5 0.4 0.5 0.2 1.1 0.4 0.5 0.2 1.1 0.4 93 9 92 300 -14.3 0.1 -14 -14.6 11/14/2005 03:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 99 0 300 300 -14 0 -13.8 -14.2 11/14/2005 03:30:00 0.4 0 0.4 0.4 0.4 0.1 0.7 0.4 0.4 0.1 0.7 0.4 65 23 300 300 -13.9 0.1 -13.6 -14 11/14/2005 03:40:00 0.4 0.1 1.1 0.4 0.4 0.1 0.7 0.4 0.4 0.1 1.1 0.4 100 43 46 300 -14.1 0.3 -13.4 -14.6 11/14/2005 03:50:00 0.4 0.1 1.1 0.4 0.4 0.1 0.7 0.4 0.4 0 0.4 0.4 66 45 62 300 -13.7 0 -13.4 -14 11/14/2005 04:00:00 0.4 0.2 1.1 0.4 0.4 0.1 1.1 0.4 0.4 0 0.4 0.4 93 10 94 300 -13.9 0.1 -13.6 -14 11/14/2005 04:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 95 0 300 300 -14.2 0.1 -14 -14.6 11/14/2005 04:20:00 0.4 0 0.7 0.4 0.4 0 0.4 0.4 0.4 0 0.7 0.4 36 22 63 300 -14.4 0.2 -14 -15 11/14/2005 04:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.5 0.2 1.1 0.4 60 56 300 300 -14.8 0 -14.6 -15 11/14/2005 04:40:00 0.4 0 0.7 0.4 0.4 0 0.4 0.4 0.4 0.2 1.1 0.4 163 0 164 300 -14.3 0.1 -14 -14.8 11/14/2005 04:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 163 0 300 300 -14.6 0.1 -14.4 -14.8 11/14/2005 05:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0.1 0.7 0.4 143 9 300 300 -15.1 0.3 -14.4 -15.5 11/14/2005 05:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 137 0 300 300 -15.5 0 -15.3 -15.5 11/14/2005 05:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0.2 1.1 0.4 228 56 300 300 -15.1 0.1 -15 -15.3 11/14/2005 05:30:00 0.5 0.3 1.9 0.4 0.4 0.3 1.5 0.4 0.7 0.3 1.5 0.4 22 47 51 300 -15.6 0.2 -15 -15.9 11/14/2005 05:40:00 0.5 0.2 1.1 0.4 0.4 0.1 1.1 0.4 0.9 0.3 1.5 0.4 64 9 57 300 -15.8 0.2 -15.3 -15.9 11/14/2005 05:50:00 0.7 0.4 1.9 0.4 0.6 0.4 1.9 0.4 0.9 0.2 1.5 0.4 86 13 65 300 -15.6 0.2 -15.1 -15.9 11/14/2005 06:00:00 1.2 0.6 2.6 0.4 1 0.6 2.3 0.4 1 0.4 1.9 0.4 68 7 66 300 -15 0.6 -14.2 -15.9 11/14/2005 06:10:00 2 0.4 3 1.1 1.8 0.4 3 1.1 1.1 0.2 1.5 0.4 60 6 57 300 -14.4 0 -14.2 -14.6 11/14/2005 06:20:00 2.7 0.4 3.4 1.9 2.6 0.4 3.8 1.9 0.8 0.3 1.5 0.4 60 5 65 300 -14.7 0.1 -14.4 -15 11/14/2005 06:30:00 3.4 0.5 5.3 2.3 3.4 0.6 5.3 2.3 1 0.4 1.9 0.4 54 6 51 300 -15 0.2 -14.6 -15.5 11/14/2005 06:40:00 3.2 0.5 4.9 2.3 3.2 0.6 4.9 2.3 1.3 0.3 2.3 0.7 61 9 63 300 -14.8 0.4 -14 -15.5 11/14/2005 06:50:00 3.2 0.6 5.3 1.9 3.2 0.7 5.3 1.9 1.6 0.6 3 0.4 79 8 87 300 -13.6 0.3 -13 -14 11/14/2005 07:00:00 3.4 0.7 5.3 1.9 3.2 0.7 5.3 1.9 1.8 0.5 3 0.4 84 8 77 300 -13.3 0.1 -13 -13.6 11/14/2005 07:10:00 2.9 0.6 4.9 1.9 2.9 0.6 4.6 1.5 1.4 0.5 2.6 0.4 76 8 73 300 -13.6 0 -13.4 -13.6 11/14/2005 07:20:00 3.9 0.4 4.9 2.6 3.8 0.4 4.9 2.3 2.4 0.4 3.4 1.5 81 6 80 300 -13.2 0.3 -12.6 -13.6 11/14/2005 07:30:00 3.3 0.8 4.6 0.7 3.2 0.9 4.9 0.4 1.8 0.7 3.8 0.4 67 12 79 300 -12.4 0.1 -12 -12.8 11/14/2005 07:40:00 2.6 0.5 3.4 1.1 2.5 0.5 3.8 0.7 1.6 0.6 2.6 0.4 89 12 85 300 -12 0 -11.8 -12.2 11/14/2005 07:50:00 2.4 0.5 3.8 0.7 2.3 0.5 3.8 1.1 1.1 0.5 2.6 0.4 99 9 90 300 -12.1 0.2 -11.8 -12.6 11/14/2005 08:00:00 1.8 0.7 3.4 0.4 1.6 0.7 3.4 0.4 0.4 0.2 1.5 0.4 85 13 83 300 -12.7 0.1 -12.6 -13 11/14/2005 08:10:00 2.9 0.6 4.2 1.9 2.8 0.6 4.2 1.5 1.3 0.5 2.3 0.4 70 8 61 300 -12.9 0 -12.6 -13.2 11/14/2005 08:20:00 4.1 0.6 6.1 2.6 4.2 0.6 6.1 2.6 2.1 0.6 3.4 0.4 56 8 69 300 -12.9 0.1 -12.6 -13.2 11/14/2005 08:30:00 5.1 0.8 7.6 3 5.1 0.8 7.6 3.4 2.7 0.8 4.9 0.7 45 9 28 300 -12.2 0.6 -11.4 -13.2 11/14/2005 08:40:00 6.7 1.2 9.9 4.2 6.7 1.2 9.5 3.4 4 1.2 6.8 1.5 44 10 43 300 -10.6 0.4 -9.7 -11.4 11/14/2005 08:50:00 6.4 1.4 11.1 3 6.4 1.5 10.7 2.6 4.2 1.5 7.6 0.7 49 13 49 300 -9.2 0.2 -8.9 -9.7 11/14/2005 09:00:00 7.3 1.2 10.7 4.2 7.3 1.3 10.7 3.4 4.9 1.3 8.4 1.5 45 12 42 300 -8.5 0.2 -8.1 -8.9 11/14/2005 09:10:00 6.7 1.3 9.9 3.4 6.7 1.3 9.9 3 5.1 1.3 9.1 2.3 46 14 41 300 -7.9 0.1 -7.6 -8.1 11/14/2005 09:20:00 6.5 1.3 10.3 3.4 6.4 1.3 10.3 3 4.8 1.4 9.5 1.9 46 15 37 300 -7.3 0.1 -7 -7.6 11/14/2005 09:30:00 6.8 1.4 10.3 3.4 6.7 1.5 10.7 2.6 5 1.6 9.5 1.1 47 13 46 300 -6.9 0.1 -6.6 -7.2 11/14/2005 09:40:00 5.3 1.4 9.1 1.1 5.3 1.4 9.1 1.5 3.9 1.3 7.2 0.7 54 18 57 300 -6.8 0 -6.6 -6.8 11/14/2005 09:50:00 5.7 1.3 9.5 2.6 5.6 1.4 9.5 2.6 4.2 1.4 8.4 1.5 50 17 49 300 -6.7 0 -6.6 -6.8 11/14/2005 10:00:00 5.8 1.7 9.9 1.5 5.8 1.7 10.3 1.9 4.7 1.4 8 1.5 50 21 54 300 -6.2 0.1 -5.9 -7 11/14/2005 10:10:00 7.1 1.6 12.6 3 7 1.7 12.2 3 5.5 1.6 9.5 1.5 45 15 35 300 -5.9 0.1 -5.7 -5.9 11/14/2005 10:20:00 7.3 1.7 11.8 3 7.2 1.7 12.2 2.3 5.9 1.7 9.9 1.9 44 17 43 300 -5.7 0 -5.5 -5.7 11/14/2005 10:30:00 7.7 1.6 12.6 3.4 7.4 1.7 13 3 6.1 1.7 11.5 2.3 41 15 40 300 -5.6 0 -5.5 -5.7 11/14/2005 10:40:00 6.9 1.6 11.1 2.3 6.7 1.6 11.1 3 5.4 1.5 10.7 2.3 42 21 41 300 -5.6 0 -5.5 -5.7 11/14/2005 10:50:00 6.7 1.7 10.7 2.6 6.5 1.6 10.3 3 5.2 1.6 10.3 0.7 44 22 32 300 -5.6 0 -5.5 -5.7 11/14/2005 11:00:00 6.2 1.4 9.5 2.6 6.1 1.4 9.5 2.6 5 1.5 8.8 1.5 49 17 59 300 -5.3 0.1 -5 -5.5 11/14/2005 11:10:00 6.2 1.9 12.6 1.9 6.1 2 12.2 1.1 4.7 1.8 10.7 1.1 51 22 53 300 -4.7 0.1 -4.4 -5 11/14/2005 11:20:00 5.1 1.7 10.7 1.1 5.2 1.7 9.9 1.1 4.7 1.4 9.5 1.9 65 22 45 300 -4.3 0 -4.4 -4.6 11/14/2005 11:30:00 3.6 1.2 6.5 0.4 3.5 1.2 6.5 0.7 2.8 1.2 5.7 0.4 67 33 45 300 -5.9 0.6 -4.4 -6.8 11/14/2005 11:40:00 4.9 1.5 8.8 1.5 4.8 1.6 8.8 1.1 4.3 1.5 8.4 1.1 51 19 46 300 -4.8 0.2 -4.4 -5.5 11/14/2005 11:50:00 3.2 1.3 7.6 0.4 3 1.3 7.2 0.4 2.8 1.2 6.5 0.4 63 29 38 300 -4.7 0.1 -4.4 -4.8 11/14/2005 12:00:00 3.5 1 6.5 1.1 3.5 1.1 6.5 1.1 3 1 5.7 0.4 67 20 82 300 -5.5 0.3 -4.6 -6.1 11/14/2005 12:10:00 2.6 0.9 5.3 0.7 2.6 1 5.3 0.7 2.1 0.8 3.8 0.4 88 38 41 300 -7.7 0.6 -6.1 -8.3 11/14/2005 12:20:00 2.4 1.2 4.9 0.4 2.3 1.2 5.3 0.4 1.4 0.9 4.2 0.4 75 33 77 300 -8.1 0 -7.9 -8.1 11/14/2005 12:30:00 2.9 1.3 5.7 0.4 2.7 1.3 6.5 0.4 2.3 1.1 5.7 0.4 66 33 32 300 -7.6 0.6 -6.4 -8.1 11/14/2005 12:40:00 3.6 1 6.5 1.1 3.4 1 6.1 0.7 2.8 1 4.9 0.7 54 18 64 300 -5.7 0.4 -5 -6.6 11/14/2005 12:50:00 5.1 1.2 9.1 2.3 5 1.3 9.1 1.9 3.8 1.2 7.2 0.7 51 17 28 300 -4.9 0 -4.8 -5 11/14/2005 13:00:00 5.1 1.3 9.5 2.3 5 1.4 9.9 1.9 3.8 1.3 8 0.7 54 17 68 300 -4.9 0 -4.6 -4.8 11/14/2005 13:10:00 4.1 1.3 7.2 0.4 4 1.3 7.6 1.5 3.1 1.1 6.8 1.1 55 19 37 300 -4.7 0 -4.4 -4.8 11/14/2005 13:20:00 3.6 1.1 6.5 0.4 3.5 1.1 6.5 0.4 3.2 1 5.7 0.7 68 22 61 300 -4.3 0.1 -3.9 -4.6 11/14/2005 13:30:00 2.4 1.1 5.7 0.4 2.3 1.1 5.7 0.4 2.4 0.9 5.7 0.7 129 43 69 300 -4.8 0.9 -3.7 -6.6 11/14/2005 13:40:00 1.1 0.7 3 0.4 1 0.7 3 0.4 1.2 0.7 3 0.4 115 45 171 300 -6.6 0 -6.4 -6.8 11/14/2005 13:50:00 1.1 0.6 2.3 0.4 1 0.7 2.6 0.4 1.1 0.6 2.6 0.4 169 38 191 300 -6.2 0.1 -5.9 -6.6 11/14/2005 14:00:00 0.7 0.4 1.9 0.4 0.5 0.3 1.9 0.4 0.8 0.4 1.9 0.4 157 58 192 300 -6.4 0 -6.1 -6.6 11/14/2005 14:10:00 1.2 0.7 3 0.4 1 0.7 3 0.4 0.9 0.5 2.3 0.4 81 58 75 300 -6.2 0.1 -5.9 -6.6 11/14/2005 14:20:00 2 0.9 4.6 0.4 1.9 1 4.6 0.4 1.4 0.8 3.4 0.4 67 22 103 300 -5.9 0 -5.5 -6.1 11/14/2005 14:30:00 2.1 1 4.6 0.4 1.9 1 4.2 0.4 1.3 0.8 3.8 0.4 52 27 70 300 -5.4 0.3 -4.8 -5.7 11/14/2005 14:40:00 3.1 1.3 6.8 0.4 3 1.3 6.8 0.4 2.6 1.3 6.1 0.4 42 30 40 300 -4.9 0 -4.6 -5.3 11/14/2005 14:50:00 2.9 1.3 6.5 0.4 2.8 1.4 6.8 0.4 2.5 1.2 6.5 0.4 73 33 59 300 -5.2 0.3 -4.6 -5.7 11/14/2005 15:00:00 1.8 0.9 4.2 0.4 1.7 0.9 4.2 0.4 1.7 0.7 4.2 0.4 143 30 129 300 -6.6 0.4 -5.7 -7.2 11/14/2005 15:10:00 1.3 0.6 2.6 0.4 1 0.6 2.6 0.4 1 0.4 2.3 0.4 98 38 101 300 -7.2 0 -7 -7.2 11/14/2005 15:20:00 1.8 0.8 5.3 0.4 1.7 0.8 4.9 0.4 1.4 0.7 4.2 0.4 81 28 36 300 -6.9 0.1 -6.6 -7 11/14/2005 15:30:00 1.6 0.8 3.8 0.4 1.5 0.8 4.2 0.4 1.4 0.6 3 0.4 78 27 104 300 -6.6 0 -6.6 -6.8 11/14/2005 15:40:00 2.2 0.6 3.8 0.7 2.2 0.7 3.8 0.7 1.9 0.7 3.8 0.4 84 19 62 300 -6.7 0 -6.6 -6.8 11/14/2005 15:50:00 2.3 0.7 4.2 0.7 2.3 0.7 4.2 0.7 1.8 0.8 3.8 0.4 57 13 48 300 -6.8 0 -6.6 -7 11/14/2005 16:00:00 2.5 0.7 4.6 1.1 2.4 0.7 4.6 0.7 1.8 0.8 3.8 0.4 51 22 42 300 -7.2 0 -6.8 -7.4 11/14/2005 16:10:00 1.8 0.5 3 0.4 1.7 0.5 3 0.7 1.4 0.5 3 0.4 74 22 62 300 -7.7 0.2 -7.2 -8.1 11/14/2005 16:20:00 1.6 0.6 3.4 0.4 1.4 0.7 3.4 0.4 0.9 0.6 2.6 0.4 86 15 82 300 -8.3 0.1 -7.9 -8.5 11/14/2005 16:30:00 1.8 0.6 3.4 0.4 1.7 0.6 3.4 0.4 1.3 0.5 2.6 0.4 80 12 63 300 -8.5 0 -8.5 -8.5 11/14/2005 16:40:00 2.1 0.6 3.8 0.4 2.1 0.6 3.4 0.7 1.6 0.6 3.4 0.4 89 19 77 300 -8.5 0 -8.5 -8.7 11/14/2005 16:50:00 1.4 0.5 2.6 0.4 1.3 0.5 2.3 0.4 1.1 0.5 2.6 0.4 90 14 79 300 -8.7 0 -8.7 -8.9 11/14/2005 17:00:00 2.3 0.8 4.2 0.7 2.2 0.8 4.2 0.4 1.6 0.6 3.4 0.4 76 13 53 300 -8.6 0.1 -8.5 -8.9 11/14/2005 17:10:00 2.5 0.7 4.2 0.7 2.4 0.7 4.6 0.4 1.8 0.7 3 0.4 73 12 80 300 -8.6 0 -8.5 -8.7 11/14/2005 17:20:00 2.9 0.7 5.3 1.1 2.8 0.7 5.3 1.1 1.8 0.7 4.9 0.4 72 9 68 300 -9 0.1 -8.7 -9.1 11/14/2005 17:30:00 3.4 0.6 5.3 1.9 3.4 0.6 5.7 1.5 2.4 0.7 3.8 0.4 73 9 63 300 -8.9 0.1 -8.7 -9.1 11/14/2005 17:40:00 3.4 0.6 5.3 1.9 3.4 0.7 5.3 1.5 2.6 0.6 3.8 0.7 81 12 88 300 -8.8 0.1 -8.7 -9.3 11/14/2005 17:50:00 2.5 0.7 3.8 0.7 2.5 0.7 4.2 0.7 1.7 0.6 3.4 0.4 88 13 75 300 -9.1 0.1 -8.9 -9.3 11/14/2005 18:00:00 2.3 0.6 3.8 0.7 2.2 0.6 3.4 0.7 1.4 0.4 2.3 0.4 92 15 75 300 -9.1 0 -8.9 -9.3 11/14/2005 18:10:00 2.6 0.6 3.8 0.7 2.6 0.7 4.2 0.7 1.7 0.7 3.4 0.4 68 12 74 300 -9 0 -8.9 -9.3 11/14/2005 18:20:00 3.7 0.9 6.1 1.9 3.7 1 6.1 1.1 3 0.9 4.9 0.7 75 15 75 300 -8.5 0.2 -8.1 -8.9 11/14/2005 18:30:00 3.8 0.6 5.3 1.9 3.9 0.6 5.3 1.9 3.2 0.7 4.9 1.1 80 11 89 300 -8.1 0 -7.9 -8.1 11/14/2005 18:40:00 3.3 0.7 5.7 1.5 3.3 0.7 5.3 1.5 2.8 0.7 5.3 0.7 74 13 57 300 -7.9 0.1 -7.6 -8.1 11/14/2005 18:50:00 3.8 1.1 6.8 1.9 3.7 1.1 6.8 1.5 2.8 0.9 5.3 0.7 56 19 41 300 -7.5 0.4 -7 -8.1 11/14/2005 19:00:00 2.9 0.7 4.9 1.1 2.8 0.8 4.6 0.7 2.4 0.5 3.8 1.1 79 21 97 300 -7.2 0.1 -7 -7.6 11/14/2005 19:10:00 2.2 0.6 3.8 0.7 2.1 0.6 3.8 0.7 1.6 0.6 3 0.4 73 21 85 300 -7.6 0 -7.2 -7.6 11/14/2005 19:20:00 1.4 0.9 3.8 0.4 1.3 0.8 3.4 0.4 1.1 0.7 2.6 0.4 104 22 69 300 -7.9 0.2 -7.4 -8.1 11/14/2005 19:30:00 1.1 0.5 2.6 0.4 1 0.4 2.3 0.4 1.6 0.5 2.3 0.4 144 38 60 300 -8.1 0 -8.1 -8.3 11/14/2005 19:40:00 1.7 0.6 4.6 0.4 1.6 0.7 4.9 0.4 1.7 0.4 3 0.4 149 32 79 300 -8.2 0 -8.1 -8.3 11/14/2005 19:50:00 1.3 0.4 2.3 0.4 1.2 0.4 2.3 0.4 1.4 0.3 1.9 0.7 166 23 125 300 -8.3 0 -8.1 -8.5 11/14/2005 20:00:00 1.2 0.4 1.9 0.4 1.1 0.4 1.9 0.4 1.1 0.4 1.9 0.4 170 19 160 300 -8.5 0 -8.3 -8.5 11/14/2005 20:10:00 0.6 0.4 1.9 0.4 0.7 0.4 1.5 0.4 0.7 0.4 1.5 0.4 172 32 158 300 -8.6 0 -8.5 -8.7 11/14/2005 20:20:00 0.7 0.4 1.5 0.4 0.6 0.3 1.9 0.4 0.7 0.4 1.5 0.4 143 24 166 300 -8.6 0 -8.5 -8.7 11/14/2005 20:30:00 0.6 0.4 1.9 0.4 0.6 0.4 2.3 0.4 0.4 0.1 1.1 0.4 97 18 106 300 -8.5 0 -8.5 -8.7 11/14/2005 20:40:00 1.1 0.5 1.9 0.4 1 0.5 1.9 0.4 1 0.4 1.9 0.4 143 13 145 300 -8.6 0 -8.5 -8.7 11/14/2005 20:50:00 0.6 0.3 1.9 0.4 0.5 0.3 1.5 0.4 0.5 0.3 1.5 0.4 129 16 107 300 -8.7 0 -8.7 -8.7 11/14/2005 21:00:00 0.8 0.4 1.5 0.4 0.7 0.4 1.5 0.4 0.4 0.2 1.1 0.4 104 11 119 300 -8.7 0 -8.5 -8.7 11/14/2005 21:10:00 1.4 0.5 3 0.4 1.2 0.6 3 0.4 0.8 0.5 2.3 0.4 97 13 79 300 -8.6 0 -8.5 -8.7 11/14/2005 21:20:00 1.5 0.4 3 0.7 1.4 0.4 3 0.4 1 0.4 2.3 0.4 97 12 114 300 -8.5 0 -8.5 -8.5 11/14/2005 21:30:00 1.7 0.7 3.8 0.4 1.7 0.7 3.8 0.4 1.1 0.6 2.3 0.4 96 26 63 300 -8.4 0 -8.3 -8.5 11/14/2005 21:40:00 2.2 0.5 3.8 0.7 2.2 0.5 3.8 1.1 1.6 0.6 3 0.4 86 20 79 300 -8.2 0 -8.1 -8.3 11/14/2005 21:50:00 2.1 0.4 3 0.7 2 0.4 3 1.1 1.4 0.6 2.3 0.4 127 7 133 300 -8.3 0 -8.1 -8.5 11/14/2005 22:00:00 1.3 0.5 2.6 0.4 1.2 0.5 2.6 0.4 0.7 0.5 2.3 0.4 118 14 129 300 -8.3 0 -8.1 -8.5 11/14/2005 22:10:00 1 0.5 2.3 0.4 0.9 0.5 2.3 0.4 0.8 0.4 1.9 0.4 61 29 95 300 -8.1 0 -8.1 -8.3 11/14/2005 22:20:00 1.4 0.4 2.3 0.4 1.2 0.5 2.3 0.4 1.2 0.6 2.6 0.4 118 33 157 300 -8 0 -7.9 -8.1 11/14/2005 22:30:00 0.9 0.6 3 0.4 0.8 0.6 2.6 0.4 0.6 0.4 1.9 0.4 92 26 96 300 -8 0 -8.1 -8.1 11/14/2005 22:40:00 1.2 0.5 3.4 0.4 1 0.5 2.6 0.4 0.7 0.4 2.3 0.4 99 15 30 300 -8.1 0 -8.1 -8.1 11/14/2005 22:50:00 1.5 0.5 2.6 0.4 1.4 0.5 2.6 0.4 1.3 0.5 2.3 0.4 125 16 132 300 -8.1 0 -8.1 -8.1 11/14/2005 23:00:00 1.1 0.5 2.3 0.4 1 0.5 2.3 0.4 0.7 0.3 1.5 0.4 128 18 146 300 -8.2 0 -8.1 -8.1 11/14/2005 23:10:00 0.8 0.5 1.9 0.4 0.7 0.5 1.9 0.4 0.6 0.4 1.5 0.4 102 18 100 300 -8.2 0 -8.1 -8.3 11/14/2005 23:20:00 1.3 0.3 1.9 0.4 1.1 0.4 1.9 0.4 1.1 0.3 1.9 0.4 87 8 82 300 -8.2 0 -8.1 -8.1 11/14/2005 23:30:00 0.9 0.5 2.3 0.4 0.8 0.5 2.3 0.4 0.6 0.3 1.5 0.4 86 17 111 300 -8.2 0 -8.1 -8.1 11/14/2005 23:40:00 1.2 0.4 1.9 0.4 1 0.4 1.9 0.4 0.9 0.4 1.5 0.4 93 10 92 300 -8.2 0 -8.1 -8.1 11/14/2005 23:50:00 0.5 0.2 1.1 0.4 0.4 0.1 1.1 0.4 0.4 0.1 0.7 0.4 102 5 108 300 -8.2 0 -8.1 -8.1 11/15/2005 00:00:00 1.2 0.6 2.3 0.4 1.1 0.5 2.3 0.4 0.8 0.4 1.9 0.4 135 21 105 300 -8.1 0 -8.1 -8.1 11/15/2005 00:10:00 0.7 0.4 1.5 0.4 0.5 0.3 1.5 0.4 0.4 0.1 1.1 0.4 144 12 151 300 -8.1 0 -8.1 -8.1 11/15/2005 00:20:00 0.7 0.4 1.5 0.4 0.6 0.3 1.5 0.4 0.5 0.3 1.1 0.4 166 3 160 300 -8.2 0 -8.1 -8.1 11/15/2005 00:30:00 0.4 0.1 0.7 0.4 0.4 0 0.7 0.4 0.4 0 0.4 0.4 167 0 167 300 -8.2 0 -8.1 -8.1 11/15/2005 00:40:00 0.5 0.4 1.9 0.4 0.5 0.3 1.9 0.4 0.5 0.3 1.5 0.4 167 1 174 300 -8.1 0 -8.1 -8.1 11/15/2005 00:50:00 0.8 0.5 1.9 0.4 0.7 0.4 1.9 0.4 0.8 0.4 1.9 0.4 180 12 177 300 -8.1 0 -8.1 -8.1 11/15/2005 01:00:00 1.1 0.6 2.3 0.4 1.2 0.5 2.3 0.4 1.2 0.4 1.9 0.4 188 16 188 300 -8 0 -7.9 -8.1 11/15/2005 01:10:00 1.2 0.7 3.4 0.4 1.2 0.7 3.8 0.4 1.2 0.6 3 0.4 146 66 119 300 -8 0 -7.9 -8.1 11/15/2005 01:20:00 1.7 0.9 4.6 0.4 1.6 0.9 4.6 0.4 1.3 0.6 4.2 0.4 100 43 39 300 -7.9 0 -7.6 -8.1 11/15/2005 01:30:00 2.4 1.2 6.1 0.4 2.4 1.2 6.1 0.4 2 1.2 5.7 0.4 105 36 67 300 -7.6 0 -7.2 -7.9 11/15/2005 01:40:00 2.8 1.3 6.8 0.4 2.7 1.2 7.2 0.4 2.3 0.9 4.2 0.4 82 22 92 300 -7.4 0 -7 -7.6 11/15/2005 01:50:00 3.3 1.1 5.7 0.4 3.2 1.1 6.1 0.7 2.5 1 5.3 0.4 106 22 80 300 -7.5 0 -7.2 -7.6 11/15/2005 02:00:00 2.4 0.7 4.9 0.7 2.4 0.8 4.9 0.7 1.7 0.8 4.2 0.4 98 21 86 300 -7.4 0.2 -7 -7.6 11/15/2005 02:10:00 4.2 1.5 10.3 1.1 4.3 1.6 10.3 0.7 3.6 1.3 8.4 0.4 60 17 43 300 -5.8 0.7 -4.8 -7 11/15/2005 02:20:00 3.7 1 6.5 1.5 3.6 1 6.5 1.5 3.3 0.8 6.1 1.9 76 16 73 300 -4.9 0 -4.8 -5.3 11/15/2005 02:30:00 2.8 0.7 4.9 0.7 2.8 0.8 4.6 0.4 2.3 0.7 3.8 0.4 89 14 94 300 -6.4 0.3 -5.3 -6.8 11/15/2005 02:40:00 2.1 0.5 4.9 0.7 2 0.6 4.9 0.7 1.5 0.5 2.6 0.4 72 17 48 300 -6.9 0.1 -6.6 -7 11/15/2005 02:50:00 2.3 0.5 3.4 1.1 2.3 0.5 3.8 1.1 1.8 0.4 3 0.4 89 17 126 300 -7.3 0 -7 -7.4 11/15/2005 03:00:00 2.2 0.6 3.8 0.7 2.1 0.7 3.4 0.4 1.4 0.6 2.6 0.4 67 17 69 300 -7.3 0 -7.2 -7.4 11/15/2005 03:10:00 2.1 0.6 3.4 0.4 2.1 0.7 3.4 0.4 1.6 0.6 3 0.4 68 13 72 300 -7.3 0 -7.2 -7.4 11/15/2005 03:20:00 0.9 0.5 2.3 0.4 0.7 0.5 2.3 0.4 0.6 0.4 1.9 0.4 72 29 57 300 -7.2 0 -7.2 -7.2 11/15/2005 03:30:00 0.8 0.5 2.3 0.4 0.7 0.5 2.3 0.4 0.5 0.4 1.9 0.4 103 12 91 300 -7.2 0 -7.2 -7.2 11/15/2005 03:40:00 1.3 0.3 2.3 0.7 1.1 0.3 1.9 0.4 0.9 0.3 1.9 0.4 83 15 60 300 -7.2 0 -7 -7.2 11/15/2005 03:50:00 1.4 0.4 2.3 0.4 1.3 0.4 2.3 0.4 1.2 0.3 1.9 0.4 73 10 95 300 -7.1 0 -7 -7.2 11/15/2005 04:00:00 1.8 0.3 2.3 0.7 1.7 0.3 2.3 0.7 1.6 0.3 2.3 0.7 87 11 92 300 -7.1 0 -7 -7 11/15/2005 04:10:00 1.8 0.3 2.6 0.4 1.7 0.3 2.3 0.4 1.5 0.3 2.3 0.4 81 10 77 300 -7.1 0 -6.8 -7 11/15/2005 04:20:00 1.9 0.4 2.6 0.7 1.8 0.4 2.6 0.4 1.4 0.4 2.3 0.4 74 7 79 300 -7 0 -6.8 -7 11/15/2005 04:30:00 1.4 0.5 2.3 0.4 1.3 0.5 2.3 0.4 1.1 0.5 1.9 0.4 68 13 77 300 -6.8 0 -6.8 -7 11/15/2005 04:40:00 1.3 0.3 1.9 0.7 1.1 0.3 1.9 0.4 1.1 0.4 1.9 0.4 70 16 71 300 -6.7 0 -6.6 -6.8 11/15/2005 04:50:00 0.8 0.4 1.9 0.4 0.7 0.4 1.9 0.4 1 0.3 1.5 0.4 80 13 93 300 -6.6 0 -6.6 -6.8 11/15/2005 05:00:00 0.7 0.3 1.5 0.4 0.6 0.3 1.5 0.4 0.7 0.3 1.5 0.4 118 11 125 300 -6.5 0 -6.4 -6.6 11/15/2005 05:10:00 1.6 0.3 2.3 0.7 1.5 0.3 2.3 0.4 1.3 0.4 1.9 0.4 138 11 136 300 -6.4 0 -6.1 -6.6 11/15/2005 05:20:00 1.5 0.4 2.6 0.7 1.4 0.5 2.3 0.4 1.2 0.4 2.3 0.4 137 11 137 300 -6.4 0 -6.1 -6.6 11/15/2005 05:30:00 1.7 0.4 2.6 0.7 1.6 0.5 2.6 0.4 1.2 0.4 1.9 0.4 119 17 136 300 -6.3 0 -6.1 -6.4 11/15/2005 05:40:00 1.5 0.3 2.3 0.7 1.4 0.4 2.3 0.4 1.3 0.4 2.3 0.4 107 20 73 300 -6.2 0 -6.1 -6.4 11/15/2005 05:50:00 2.2 0.3 3 1.5 2.1 0.4 2.6 1.1 2.1 0.4 2.6 1.1 92 17 76 300 -6.1 0 -6.1 -6.1 11/15/2005 06:00:00 1.8 0.4 3 0.7 1.7 0.5 2.6 0.7 1.6 0.4 2.6 0.7 80 19 79 300 -6.1 0 -6.1 -6.1 11/15/2005 06:10:00 1 0.5 1.9 0.4 0.9 0.4 1.9 0.4 0.8 0.5 1.9 0.4 82 20 104 300 -6 0 -5.9 -6.1 11/15/2005 06:20:00 0.8 0.4 1.9 0.4 0.7 0.4 1.5 0.4 0.5 0.2 1.1 0.4 94 26 123 300 -6 0 -5.9 -6.1 11/15/2005 06:30:00 1.5 0.3 1.9 0.4 1.3 0.4 1.9 0.4 1.1 0.4 1.9 0.4 107 12 107 300 -6 0 -5.9 -5.9 11/15/2005 06:40:00 1.6 0.4 2.6 0.4 1.5 0.4 2.3 0.4 1.2 0.5 2.3 0.4 95 18 113 300 -5.9 0 -5.7 -5.9 11/15/2005 06:50:00 1.3 0.5 2.3 0.4 1.1 0.5 2.3 0.4 0.9 0.5 1.9 0.4 89 13 84 300 -5.8 0 -5.7 -5.9 11/15/2005 07:00:00 1.3 0.6 2.6 0.4 1.2 0.6 2.6 0.4 0.9 0.5 2.3 0.4 85 13 113 300 -5.7 0 -5.5 -5.7 11/15/2005 07:10:00 2 0.5 3.8 0.7 2 0.6 3.4 0.7 1.7 0.6 3.4 0.4 78 13 64 300 -5.7 0 -5.7 -5.7 11/15/2005 07:20:00 3 0.7 6.1 1.9 3.1 0.7 6.1 1.5 2.4 0.7 5.7 1.1 75 16 77 300 -5.7 0 -5.5 -5.7 11/15/2005 07:30:00 2.8 0.7 4.9 1.5 2.8 0.7 5.3 1.5 2.2 0.6 4.6 0.7 74 12 78 300 -5.5 0.1 -5.3 -5.7 11/15/2005 07:40:00 3 0.5 4.6 1.9 3 0.6 4.6 1.9 2.3 0.6 3.8 1.1 68 11 40 300 -5.2 0.1 -4.8 -5.5 11/15/2005 07:50:00 3.3 0.5 4.6 1.9 3.3 0.5 4.6 1.9 2.7 0.6 4.2 1.1 77 8 83 300 -4.9 0 -4.8 -5 11/15/2005 08:00:00 2.9 0.5 4.2 1.1 2.9 0.5 3.8 1.1 2.2 0.5 3.4 0.7 77 8 67 300 -4.9 0 -4.6 -4.8 11/15/2005 08:10:00 2.9 0.4 4.6 1.9 2.9 0.5 4.9 1.9 2.2 0.5 3.4 0.7 76 8 57 300 -4.9 0 -4.8 -5 11/15/2005 08:20:00 2.3 0.4 3.4 1.5 2.3 0.4 3.4 1.1 1.7 0.4 2.6 0.7 76 9 96 300 -5 0 -4.8 -5.3 11/15/2005 08:30:00 2.6 0.4 4.2 1.5 2.6 0.4 4.2 1.1 2 0.5 3 0.7 80 9 62 300 -5.3 0.1 -5 -5.5 11/15/2005 08:40:00 3.2 0.5 4.6 1.5 3.2 0.5 4.2 1.1 2.3 0.5 3.4 1.1 79 9 82 300 -5.4 0 -5.3 -5.5 11/15/2005 08:50:00 2.4 0.6 4.6 1.1 2.3 0.6 4.6 1.1 1.7 0.5 3.4 0.7 88 15 34 300 -5.5 0 -5.3 -5.7 11/15/2005 09:00:00 2.3 0.6 4.6 1.1 2.2 0.6 4.6 0.7 1.4 0.6 3 0.4 81 12 59 300 -5.5 0 -5.5 -5.7 11/15/2005 09:10:00 2.5 0.4 3.4 1.5 2.5 0.4 3.4 1.1 1.8 0.4 2.6 0.7 83 12 67 300 -5.4 0 -5.5 -5.5 11/15/2005 09:20:00 2.7 0.6 5.3 1.1 2.6 0.7 5.3 1.1 1.9 0.4 3 0.7 56 13 48 300 -5.3 0 -5 -5.5 11/15/2005 09:30:00 2.9 1 6.5 0.7 2.9 1 6.8 1.1 1.8 0.8 4.2 0.4 54 20 39 300 -5.3 0 -5 -5.5 11/15/2005 09:40:00 4.2 1 6.8 1.5 4 1.1 6.8 1.5 2.6 0.9 4.6 0.4 44 15 52 300 -4.3 0.5 -3.7 -5.5 11/15/2005 09:50:00 2.6 1.2 6.8 0.4 2.6 1.2 6.1 0.4 2 1 5.7 0.4 65 24 41 300 -4.4 0.3 -3.9 -5 11/15/2005 10:00:00 1.6 1 4.2 0.4 1.7 1 4.2 0.4 1.4 0.5 3.4 0.4 87 24 92 300 -5.1 0 -5 -5.3 11/15/2005 10:10:00 3.4 0.5 4.9 2.3 3.4 0.5 5.3 1.9 2.6 0.5 3.8 1.1 65 10 62 300 -4.7 0.2 -4.4 -5 11/15/2005 10:20:00 4.4 0.9 7.2 2.3 4.3 1 7.2 2.3 3.1 0.8 6.1 1.5 52 12 34 300 -3.7 0.3 -2.8 -4.4 11/15/2005 10:30:00 6.1 1.5 10.3 2.6 5.8 1.6 9.5 2.3 4.4 1.7 9.5 1.1 38 15 29 300 -1.5 1 0.2 -2.8 11/15/2005 10:40:00 5.8 1.7 9.9 1.5 5.5 1.7 10.3 1.1 4.1 1.5 8 0.4 48 26 38 300 0.5 0.1 0.7 -0.1 11/15/2005 10:50:00 2.1 0.8 4.9 0.4 2 0.8 4.6 0.4 2 0.6 4.2 0.4 150 39 105 300 -3 1.2 -0.1 -4.4 11/15/2005 11:00:00 1.5 0.6 3 0.4 1.4 0.6 3 0.4 1.5 0.6 2.6 0.4 97 51 70 300 -4.4 0 -4.4 -4.6 11/15/2005 11:10:00 1.4 0.5 2.6 0.4 1.3 0.5 2.3 0.4 1.5 0.5 2.6 0.4 164 27 154 300 -4.8 0 -4.4 -4.8 11/15/2005 11:20:00 0.7 0.4 1.5 0.4 0.8 0.5 2.3 0.4 1.1 0.5 2.3 0.4 193 19 220 300 -4.8 0 -4.6 -4.8 11/15/2005 11:30:00 1.2 0.4 1.9 0.4 1.3 0.4 2.3 0.4 1.3 0.5 2.3 0.4 213 9 205 300 -4.8 0 -4.6 -4.8 11/15/2005 11:40:00 1 0.3 1.5 0.4 0.8 0.3 1.5 0.4 1 0.3 1.5 0.4 227 9 239 300 -4.5 0 -4.4 -4.6 11/15/2005 11:50:00 1.6 0.4 2.3 0.7 1.5 0.4 2.3 0.4 1.6 0.3 2.3 0.7 230 12 236 300 -4.4 0 -4.4 -4.6 11/15/2005 12:00:00 1.7 0.5 2.6 0.4 1.8 0.4 2.6 0.4 1.7 0.5 2.6 0.4 219 10 226 300 -4.4 0 -4.4 -4.6 11/15/2005 12:10:00 1.3 0.5 2.3 0.4 1.5 0.5 2.6 0.4 1.4 0.4 2.6 0.4 211 9 195 300 -4.3 0 -4.4 -4.4 11/15/2005 12:20:00 1.1 0.4 2.3 0.4 1.3 0.5 2.6 0.4 1.2 0.4 1.9 0.4 206 10 210 300 -4.2 0.1 -3.9 -4.4 11/15/2005 12:30:00 0.7 0.4 1.5 0.4 0.7 0.4 1.5 0.4 0.5 0.2 1.5 0.4 191 3 186 300 -3.9 0 -3.7 -4.2 11/15/2005 12:40:00 0.9 0.4 1.9 0.4 0.9 0.5 1.9 0.4 0.9 0.5 1.9 0.4 197 7 191 300 -3.7 0 -3.5 -3.7 11/15/2005 12:50:00 1.9 0.8 3.4 0.4 1.9 0.8 3.4 0.4 1.5 0.6 3 0.4 226 9 237 300 -3.7 0 -3.5 -3.7 11/15/2005 13:00:00 2.7 0.4 3.4 1.9 2.6 0.4 3.4 1.9 2.2 0.4 3.4 1.5 236 7 239 300 -3.4 0 -3.3 -3.5 11/15/2005 13:10:00 2.4 0.5 3.4 1.1 2.3 0.5 3.4 1.1 1.9 0.4 3 1.1 243 6 234 300 -3.1 0 -2.8 -3.3 11/15/2005 13:20:00 3.5 0.6 5.3 2.3 3.4 0.5 4.9 1.9 2.9 0.6 4.2 1.5 243 6 237 300 -2.8 0 -2.6 -3 11/15/2005 13:30:00 2.7 0.9 4.6 0.7 2.6 0.9 4.6 0.7 2.2 0.9 4.2 0.4 241 13 243 300 -2.5 0 -2.1 -2.6 11/15/2005 13:40:00 2.6 0.6 4.2 1.1 2.6 0.6 4.2 1.1 2.1 0.6 3.8 0.7 245 12 234 300 -2.2 0 -2.1 -2.4 11/15/2005 13:50:00 2.7 0.7 4.2 1.5 2.6 0.6 4.2 1.1 2.2 0.7 3.4 0.7 239 11 223 300 -2.1 0 -1.9 -2.1 11/15/2005 14:00:00 3 0.6 4.6 1.5 2.9 0.6 4.6 1.5 2.6 0.6 4.6 1.5 242 9 239 300 -2 0 -1.9 -2.1 11/15/2005 14:10:00 3.4 0.7 4.9 1.5 3.3 0.7 4.9 1.5 3 0.8 4.9 1.5 237 9 238 300 -1.9 0 -1.9 -1.9 11/15/2005 14:20:00 3.4 0.8 4.9 1.1 3.3 0.8 4.9 1.5 2.7 0.7 4.2 0.7 232 14 237 300 -2 0 -1.9 -2.1 11/15/2005 14:30:00 3.4 0.7 5.3 1.5 3.4 0.7 4.9 1.5 2.7 0.7 4.9 1.1 233 14 232 300 -2.1 0 -2.1 -2.1 11/15/2005 14:40:00 3.2 0.5 4.6 1.9 3.1 0.5 4.6 1.9 2.6 0.6 4.2 0.7 234 10 242 300 -2.2 0 -2.1 -2.4 11/15/2005 14:50:00 3.7 0.8 5.3 1.9 3.7 0.7 5.3 1.9 3 0.7 4.9 1.5 230 11 233 300 -2.4 0 -2.1 -2.6 11/15/2005 15:00:00 3.8 0.9 6.1 1.9 3.9 0.8 6.1 1.9 3.3 0.9 5.3 1.5 228 11 225 300 -2.5 0 -2.4 -2.6 11/15/2005 15:10:00 3.7 0.9 5.7 1.5 3.6 0.8 5.7 1.1 3.1 0.8 5.3 1.1 235 13 241 300 -2.5 0 -2.4 -2.6 11/15/2005 15:20:00 3.4 0.7 4.9 1.5 3.4 0.7 5.3 1.5 2.9 0.9 4.9 0.4 239 13 233 300 -2.5 0 -2.4 -2.6 11/15/2005 15:30:00 2.9 0.9 4.9 0.7 2.8 0.9 4.9 0.7 2.4 0.9 4.9 0.7 240 13 233 300 -2.4 0 -2.4 -2.6 11/15/2005 15:40:00 2 0.6 3.4 0.4 1.9 0.6 3.4 0.4 1.1 0.5 3 0.4 239 21 256 300 -2.4 0 -2.1 -2.4 11/15/2005 15:50:00 2.5 0.8 4.6 0.7 2.5 0.8 4.2 0.7 2.2 0.8 3.8 0.4 237 17 264 300 -2.2 0 -2.1 -2.4 11/15/2005 16:00:00 3.1 0.7 4.6 1.5 3 0.7 4.6 1.5 2.4 0.7 4.2 0.7 247 13 249 300 -2.2 0 -2.1 -2.4 11/15/2005 16:10:00 3.1 0.7 4.6 1.1 3 0.7 4.6 1.1 2.6 0.7 4.2 1.1 247 12 256 300 -2.1 0 -1.9 -2.1 11/15/2005 16:20:00 3.5 0.7 4.9 1.1 3.4 0.6 4.9 1.1 2.5 0.8 4.6 0.7 247 12 265 300 -2.1 0 -1.9 -2.1 11/15/2005 16:30:00 3.1 0.7 4.9 1.1 2.9 0.8 4.9 0.7 2.4 0.6 4.2 0.7 247 13 209 300 -2.1 0 -1.9 -2.1 11/15/2005 16:40:00 3.2 0.7 4.9 1.5 3.1 0.7 4.9 1.5 2.7 0.6 4.6 1.5 260 16 271 300 -2 0 -1.9 -2.1 11/15/2005 16:50:00 3.4 0.6 4.9 1.9 3.3 0.6 4.9 1.9 3 0.5 4.2 1.9 258 8 256 300 -2 0 -1.9 -2.1 11/15/2005 17:00:00 3.9 0.6 5.3 2.3 3.8 0.6 5.3 2.3 3.3 0.7 4.9 1.5 259 8 270 300 -2 0 -1.9 -2.1 11/15/2005 17:10:00 3.7 0.6 4.9 2.3 3.6 0.5 4.9 1.9 3.3 0.6 4.9 1.9 261 7 263 300 -2 0 -1.9 -2.1 11/15/2005 17:20:00 3.5 0.6 4.9 1.9 3.5 0.6 4.9 1.9 3.2 0.6 4.9 1.9 266 9 267 300 -1.8 0 -1.7 -1.9 11/15/2005 17:30:00 3 0.5 4.6 1.5 3 0.5 4.2 1.1 2.7 0.6 3.8 1.1 277 9 285 300 -1.8 0 -1.7 -1.9 11/15/2005 17:40:00 2.6 0.5 4.2 1.5 2.5 0.5 3.8 1.5 2.1 0.5 3 1.1 279 8 275 300 -1.8 0 -1.9 -1.9 11/15/2005 17:50:00 2.3 0.4 3 1.1 2.2 0.4 3 1.1 1.9 0.4 3 0.7 289 8 283 300 -1.8 0 -1.7 -1.9 11/15/2005 18:00:00 2.6 0.4 3.8 1.5 2.6 0.4 3.8 1.5 2.1 0.4 3 1.1 308 12 297 300 -1.8 0 -1.7 -1.9 11/15/2005 18:10:00 1.9 0.3 2.6 1.1 1.8 0.4 2.6 1.1 1.6 0.3 2.3 0.7 323 8 312 300 -1.8 0 -1.7 -1.9 11/15/2005 18:20:00 2.3 0.3 3 1.5 2.2 0.3 2.6 1.5 1.9 0.3 2.6 1.1 341 7 340 300 -2 0 -1.9 -2.1 11/15/2005 18:30:00 2 0.3 2.6 1.1 1.9 0.3 2.6 1.1 1.5 0.4 2.6 0.7 359 6 346 300 -2.1 0 -1.9 -2.1 11/15/2005 18:40:00 1.8 0.2 2.3 1.1 1.7 0.3 2.3 0.7 1.2 0.4 2.3 0.4 5 6 0 300 -2.1 0 -1.9 -2.1 11/15/2005 18:50:00 2.2 0.3 3 1.5 1.9 0.4 2.6 1.1 1.6 0.4 2.6 0.7 25 6 34 300 -2.2 0 -2.1 -2.1 11/15/2005 19:00:00 2.4 0.3 3 1.5 2.2 0.4 2.6 0.7 1.6 0.4 2.6 0.7 28 5 31 300 -2.2 0 -2.1 -2.4 11/15/2005 19:10:00 2 0.3 3 1.1 1.6 0.3 2.3 0.7 1.4 0.3 2.3 0.7 26 4 22 300 -2.2 0 -2.1 -2.4 11/15/2005 19:20:00 1.5 0.3 2.3 0.7 1.3 0.3 1.9 0.7 1.2 0.3 2.3 0.4 32 4 31 300 -2.3 0 -2.1 -2.4 11/15/2005 19:30:00 1.4 0.2 1.9 1.1 1.2 0.2 1.5 0.7 1.1 0.2 1.5 0.7 30 3 32 300 -2.4 0 -2.1 -2.4 11/15/2005 19:40:00 1.9 0.4 2.6 1.1 1.7 0.4 2.6 0.7 1.2 0.3 1.9 0.7 19 3 18 300 -2.4 0 -2.4 -2.6 11/15/2005 19:50:00 2.1 0.3 2.6 1.1 1.7 0.3 2.6 1.1 1.3 0.4 2.3 0.4 27 8 15 300 -2.6 0 -2.4 -2.8 11/15/2005 20:00:00 1.3 0.5 2.3 0.4 1.2 0.5 2.3 0.4 1.1 0.4 2.3 0.4 50 9 45 300 -2.8 0 -2.6 -2.8 11/15/2005 20:10:00 1.3 0.5 2.3 0.4 1.2 0.4 1.9 0.4 1.1 0.4 1.9 0.4 48 5 42 300 -2.7 0 -2.6 -2.8 11/15/2005 20:20:00 1.8 0.2 2.3 1.1 1.7 0.2 2.3 1.1 1.5 0.2 1.9 1.1 52 2 53 300 -3.1 0.1 -2.8 -3.5 11/15/2005 20:30:00 2.2 0.3 3 1.5 2.2 0.3 2.6 1.5 1.7 0.2 2.3 1.1 48 4 57 300 -3.8 0 -3.5 -3.9 11/15/2005 20:40:00 2.8 0.3 3.4 2.3 2.8 0.3 3.4 2.3 2.2 0.3 3 1.5 63 5 61 300 -4 0 -3.9 -4.2 11/15/2005 20:50:00 2.8 0.2 3.4 2.3 2.8 0.2 3.4 2.3 2.6 0.2 3 1.9 64 5 68 300 -4.1 0.1 -3.9 -4.4 11/15/2005 21:00:00 3.3 0.3 4.2 2.6 3.3 0.3 4.2 2.6 2.7 0.4 3.4 1.5 55 4 51 300 -4.3 0 -4.2 -4.4 11/15/2005 21:10:00 3.6 0.3 4.2 2.6 3.6 0.3 4.2 3 2.8 0.3 3.4 1.9 53 2 51 300 -4.5 0.1 -4.4 -4.8 11/15/2005 21:20:00 3.7 0.3 4.6 3 3.7 0.3 4.6 3 2.8 0.4 3.8 1.5 58 4 63 300 -4.4 0 -4.4 -4.6 11/15/2005 21:30:00 3.5 0.3 4.2 2.6 3.5 0.3 4.2 2.6 2.7 0.4 3.4 1.5 51 5 57 300 -4.6 0 -4.4 -4.8 11/15/2005 21:40:00 3.8 0.4 4.9 2.6 3.8 0.4 4.9 3 2.9 0.5 4.2 1.5 47 4 52 300 -4.3 0 -4.2 -4.6 11/15/2005 21:50:00 3.8 0.4 4.6 2.6 3.8 0.4 4.6 2.6 2.4 0.5 3.8 0.4 45 5 46 300 -4.3 0 -4.4 -4.4 11/15/2005 22:00:00 3.7 0.4 4.6 2.6 3.6 0.5 4.6 2.3 2.5 0.5 3.8 1.1 39 8 45 300 -4.2 0 -3.9 -4.4 11/15/2005 22:10:00 3.7 0.6 5.3 2.3 3.5 0.7 5.3 1.9 2.2 0.7 4.2 0.7 36 9 36 300 -4.1 0.1 -3.9 -4.4 11/15/2005 22:20:00 4.4 0.6 6.1 2.3 4.2 0.7 5.7 1.9 2.9 0.7 4.2 1.5 38 8 28 300 -4 0 -3.9 -4.4 11/15/2005 22:30:00 4.1 0.6 5.3 1.9 4 0.6 5.3 2.3 2.9 0.6 4.6 1.5 41 8 41 300 -3.9 0 -3.7 -3.9 11/15/2005 22:40:00 4.3 0.6 5.7 2.6 4.2 0.6 5.7 2.6 2.9 0.6 4.2 1.1 40 8 31 300 -4 0 -3.9 -4.2 11/15/2005 22:50:00 3.9 0.6 5.3 1.9 3.7 0.7 5.3 1.9 2.6 0.6 4.2 1.1 39 9 34 300 -3.9 0 -3.7 -3.9 11/15/2005 23:00:00 4.2 0.6 6.1 2.3 3.9 0.7 6.1 1.9 2.5 0.7 4.2 0.4 34 10 38 300 -4 0 -3.9 -4.2 11/15/2005 23:10:00 4.8 0.8 6.5 2.6 4.5 0.9 6.5 2.6 3.1 0.8 5.3 1.1 36 10 34 300 -4 0.1 -3.7 -4.4 11/15/2005 23:20:00 4.7 0.8 6.5 2.3 4.6 0.9 6.5 2.3 3.2 0.8 5.3 1.1 42 9 51 300 -3.8 0 -3.5 -3.7 11/15/2005 23:30:00 4.8 0.5 6.5 3 4.9 0.6 6.5 2.3 3.3 0.8 4.9 0.7 45 6 52 300 -3.5 0 -3.5 -3.7 11/15/2005 23:40:00 4.8 0.7 6.5 2.6 4.8 0.7 6.5 2.6 3.5 0.8 5.7 1.1 46 8 48 300 -3.5 0 -3.3 -3.7 11/15/2005 23:50:00 5.1 0.7 7.2 3.4 5.1 0.7 7.2 3 3.5 0.9 6.1 1.5 48 9 54 300 -3.2 0 -3 -3.3 11/16/2005 00:00:00 5.1 0.8 7.2 2.6 5.1 0.9 7.2 3 3.5 1 6.5 1.1 47 9 52 300 -3.1 0 -3 -3.3 11/16/2005 00:10:00 4.9 0.8 7.2 2.6 4.8 1 7.2 2.3 3.2 0.8 5.7 1.1 40 11 45 300 -3.2 0 -3 -3.3 11/16/2005 00:20:00 4.6 0.7 6.5 2.6 4.6 0.8 6.5 1.9 3.2 0.8 5.3 0.7 44 8 48 300 -3.1 0 -3 -3.3 11/16/2005 00:30:00 4.4 0.7 6.8 2.6 4.1 0.8 7.2 1.9 2.8 0.6 4.9 1.5 38 9 34 300 -3.4 0 -3.3 -3.5 11/16/2005 00:40:00 3.8 0.6 5.7 2.3 3.7 0.6 5.7 2.3 2.5 0.6 3.8 0.7 41 8 41 300 -3.7 0 -3.5 -3.9 11/16/2005 00:50:00 4.4 0.6 6.1 3 4.4 0.7 6.1 2.3 3.1 0.7 4.9 1.5 43 9 55 300 -3.8 0 -3.7 -3.9 11/16/2005 01:00:00 4.6 0.7 6.5 2.3 4.2 0.8 6.5 1.9 2.7 0.7 4.6 1.1 36 11 24 300 -3.8 0 -3.5 -3.9 11/16/2005 01:10:00 4.7 0.7 6.5 3 4.2 0.8 6.5 1.9 2.8 0.8 5.3 0.7 32 11 37 300 -3.7 0 -3.5 -3.9 11/16/2005 01:20:00 4.9 0.8 6.8 3 4.4 0.9 6.8 2.3 3 0.8 6.5 1.1 35 11 42 300 -3.7 0 -3.5 -3.9 11/16/2005 01:30:00 5.4 0.7 7.2 3 4.6 0.8 6.8 2.3 3 0.8 5.3 1.1 28 10 29 300 -3.8 0 -3.5 -3.9 11/16/2005 01:40:00 5.1 0.8 8 3.4 4.4 0.8 7.2 2.6 3 0.8 5.3 1.1 29 9 45 300 -3.7 0 -3.5 -3.9 11/16/2005 01:50:00 5.7 0.7 7.2 3.4 4.9 0.8 7.2 2.6 3.6 0.7 5.3 1.9 30 9 33 300 -3.4 0 -3.3 -3.5 11/16/2005 02:00:00 5.4 0.8 8 3.4 4.8 0.9 8 2.3 3.3 0.8 6.1 1.5 32 9 25 300 -3.1 0.1 -2.8 -3.3 11/16/2005 02:10:00 5.6 1 7.6 3 5.3 1.1 8 2.3 3.7 1 7.2 1.1 37 11 46 300 -2.8 0 -2.6 -2.8 11/16/2005 02:20:00 5.7 0.8 7.6 3.8 5.4 1 7.6 3 3.9 0.9 7.2 1.5 36 10 38 300 -2.5 0.1 -2.4 -2.6 11/16/2005 02:30:00 5.6 0.8 7.6 3.4 5 0.9 7.2 2.3 3.7 0.8 6.5 1.9 32 9 27 300 -2.4 0 -2.4 -2.6 11/16/2005 02:40:00 6 0.7 8 3.8 5 0.7 6.8 3.4 4.1 1 6.5 1.5 24 7 26 300 -2.5 0 -2.4 -2.6 11/16/2005 02:50:00 5.8 0.8 7.6 3.4 5 0.8 7.2 2.6 4.1 0.9 6.8 1.9 23 9 26 300 -2.4 0 -2.1 -2.6 11/16/2005 03:00:00 4.5 0.8 6.8 1.5 4 0.8 6.1 1.5 3.1 0.8 4.9 0.7 32 11 28 300 -2.3 0 -2.1 -2.4 11/16/2005 03:10:00 4.8 0.8 6.8 2.6 4.2 0.8 6.1 1.9 3.3 0.8 5.3 1.5 29 10 38 300 -2.2 0 -2.1 -2.4 11/16/2005 03:20:00 4.7 0.7 6.5 3 4.2 0.8 6.5 2.3 3.3 0.8 6.8 1.5 31 12 21 300 -2.1 0 -1.9 -2.4 11/16/2005 03:30:00 4.2 0.7 5.7 2.3 3.9 0.7 5.3 2.3 2.8 0.8 4.6 0.7 37 8 36 300 -2 0 -1.9 -1.9 11/16/2005 03:40:00 3.5 0.6 4.9 1.9 3.2 0.7 4.9 1.5 2.3 0.7 3.8 0.7 36 9 51 300 -1.9 0 -1.7 -2.1 11/16/2005 03:50:00 3.1 0.5 4.2 1.9 3 0.5 4.2 1.9 2.3 0.6 4.6 1.1 43 9 47 300 -1.7 0 -1.4 -1.9 11/16/2005 04:00:00 4 0.7 5.7 2.3 3.5 0.7 4.9 1.9 2.8 0.6 4.9 1.5 29 8 31 300 -1.6 0 -1.4 -1.7 11/16/2005 04:10:00 4.1 0.6 5.7 2.6 3.8 0.6 5.3 2.3 2.9 0.6 4.6 1.5 37 9 35 300 -1.2 0.2 -1 -1.4 11/16/2005 04:20:00 4 0.7 6.1 2.3 3.8 0.8 5.7 1.9 2.9 0.7 4.9 1.5 39 12 28 300 -0.9 0 -0.7 -1 11/16/2005 04:30:00 4.9 1 7.6 2.6 4.5 1 6.8 2.3 3.6 1 6.1 1.1 32 14 20 300 -0.6 0 -0.3 -0.7 11/16/2005 04:40:00 4.9 1.1 7.6 2.6 4.6 1.1 8 2.3 3.7 1 6.5 1.5 37 14 46 300 -0.2 0 -0.1 -0.5 11/16/2005 04:50:00 5.2 1.1 8.4 2.3 4.9 1.1 8 2.3 3.6 1 5.7 1.5 36 13 27 300 0 0 0.2 -0.1 11/16/2005 05:00:00 5.2 1.2 8 2.3 4.9 1.2 8 1.9 3.8 1.3 7.2 1.1 40 15 59 300 0.1 0 0.2 0.2 11/16/2005 05:10:00 5.7 1.2 9.9 2.3 5.2 1.2 9.9 2.3 4.1 1.2 7.2 1.5 34 15 14 300 0.3 0 0.4 0.2 11/16/2005 05:20:00 4.5 1.3 8 1.1 4.3 1.4 7.6 1.1 3.6 1.2 7.2 1.1 45 22 26 300 0.5 0 0.7 0.4 11/16/2005 05:30:00 2.5 1.2 6.1 0.4 2.3 1.2 6.1 0.4 1.9 1 4.9 0.4 74 43 63 300 -0.4 0.7 0.7 -1.2 11/16/2005 05:40:00 2.7 1.3 7.2 0.4 2.6 1.3 7.2 0.4 2 1 5.7 0.4 61 47 52 300 -1.1 0.4 -0.5 -2.1 11/16/2005 05:50:00 1.5 0.6 3.4 0.4 1.4 0.6 3.4 0.4 1.5 0.6 3 0.4 130 47 95 300 -2.8 0.3 -2.1 -3.3 11/16/2005 06:00:00 1.8 0.8 4.6 0.4 1.7 0.7 4.2 0.4 0.9 0.5 2.3 0.4 53 32 71 300 -3.1 0 -2.8 -3.3 11/16/2005 06:10:00 2.7 0.8 4.6 0.7 2.5 0.8 4.6 0.7 1.2 0.7 3 0.4 35 19 38 300 -2.8 0 -2.6 -2.8 11/16/2005 06:20:00 2.5 0.7 4.9 0.7 2.4 0.8 4.9 0.4 1.5 0.7 3.4 0.4 41 30 54 300 -2.6 0 -2.6 -2.8 11/16/2005 06:30:00 4 1.2 7.2 0.7 3.7 1.1 7.2 0.7 2.9 0.9 5.3 0.7 36 22 24 300 -1.4 0.7 -0.5 -2.6 11/16/2005 06:40:00 5.4 1.7 10.3 1.1 5 1.7 9.1 1.1 4.2 1.5 8.8 0.7 32 17 41 300 -0.1 0.4 0.4 -0.7 11/16/2005 06:50:00 7.3 1.4 11.1 3.8 6.8 1.5 10.3 3.4 5.3 1.3 9.1 2.3 27 15 43 300 0.1 0 0.4 -0.1 11/16/2005 07:00:00 7.5 1.5 11.8 3.4 6.9 1.5 11.1 3.4 5.7 1.4 9.5 1.9 28 15 23 300 -0.3 0.1 -0.1 -0.5 11/16/2005 07:10:00 8.4 1.5 13 4.2 7.7 1.3 11.8 3.8 6.5 1.3 9.9 3 29 12 20 300 -0.5 0 -0.5 -0.5 11/16/2005 07:20:00 7.9 1.5 11.8 3.8 7.4 1.5 11.5 4.2 6.1 1.4 10.7 3.4 28 15 38 300 -0.5 0 -0.5 -0.5 11/16/2005 07:30:00 6.6 1.4 10.3 2.6 6.1 1.4 9.9 2.3 5.1 1.1 8.4 3 30 15 17 300 -0.5 0 -0.5 -0.5 11/16/2005 07:40:00 5.3 1.7 9.1 0.7 4.9 1.7 8.8 0.7 4.1 1.4 7.2 0.7 34 17 21 300 -0.6 0 -0.5 -0.7 11/16/2005 07:50:00 5.9 1.4 8.8 2.3 5.5 1.5 8.8 1.9 4.5 1.2 7.2 1.5 38 17 40 300 -0.7 0.1 -0.5 -0.7 11/16/2005 08:00:00 4.7 1.3 7.6 2.3 4.5 1.3 7.6 1.5 3.5 1.1 6.5 1.1 49 20 31 300 -0.8 0 -0.7 -0.7 11/16/2005 08:10:00 4.1 1.2 7.6 1.1 4 1.3 7.2 0.7 3.4 1.2 7.6 0.7 50 21 27 300 -0.7 0 -0.5 -0.7 11/16/2005 08:20:00 4.2 1.2 8.4 1.1 4.1 1.2 8 1.1 3.3 1 6.8 1.1 46 22 49 300 -0.8 0 -0.7 -0.7 11/16/2005 08:30:00 5.5 1.5 8.8 1.9 5.1 1.5 8.8 1.5 4.2 1.5 8 1.1 37 21 20 300 -0.7 0 -0.5 -0.7 11/16/2005 08:40:00 6.6 1.5 9.9 1.9 6 1.4 9.9 2.3 4.9 1.3 8.8 2.3 28 21 22 300 -0.7 0 -0.5 -0.7 11/16/2005 08:50:00 7.4 1.5 10.7 2.6 6.7 1.4 10.3 1.9 5.7 1.3 9.9 2.6 25 13 18 300 -0.7 0 -0.5 -0.7 11/16/2005 09:00:00 8.2 1.8 11.8 3.4 7.5 1.7 11.8 3.4 6.3 1.6 11.1 2.6 25 13 26 300 -0.9 0 -0.7 -0.7 11/16/2005 09:10:00 8.3 1.5 12.2 3.8 7.5 1.5 11.5 3.4 6.2 1.4 10.7 3 22 14 30 300 -0.9 0 -0.7 -1 11/16/2005 09:20:00 8.6 1.5 12.6 4.9 7.8 1.6 12.6 4.2 6.4 1.4 10.7 2.6 23 12 25 300 -0.9 0 -0.7 -1 11/16/2005 09:30:00 8.2 1.6 11.8 4.6 7.6 1.6 11.8 3.4 6.3 1.5 11.8 3.4 22 13 18 300 -0.8 0 -0.7 -0.7 11/16/2005 09:40:00 8.9 1.6 12.2 4.2 8.1 1.5 12.6 4.2 6.9 1.5 11.1 3.8 24 11 25 300 -0.9 0 -0.7 -1 11/16/2005 09:50:00 9.4 1.8 13.7 4.6 8.5 1.6 11.8 4.6 7.2 1.6 11.1 3 27 12 25 300 -0.9 0 -0.7 -0.7 11/16/2005 10:00:00 9.3 1.6 13 4.2 8.5 1.5 12.2 3 7.1 1.5 11.8 3.4 26 12 20 300 -0.9 0 -0.7 -1 11/16/2005 10:10:00 9.5 1.6 13 5.3 8.5 1.5 13 4.6 7.1 1.5 11.5 3.4 25 12 28 300 -0.9 0 -0.7 -1 11/16/2005 10:20:00 9.3 1.5 12.6 5.3 8.5 1.4 12.2 4.6 7.1 1.5 12.2 3 29 12 24 300 -0.9 0 -0.7 -1 11/16/2005 10:30:00 9.6 1.5 13.3 4.9 8.8 1.5 13 4.2 7.6 1.6 11.8 3.8 27 12 17 300 -0.8 0 -0.7 -0.7 11/16/2005 10:40:00 9.9 1.9 14.9 5.3 9 1.7 14.5 4.2 7.7 1.7 13.3 4.6 26 12 25 300 -0.7 0 -0.7 -0.7 11/16/2005 10:50:00 9.3 1.7 14.1 4.9 8.6 1.6 13 4.2 7.2 1.5 13 3.8 23 13 23 300 -0.8 0 -0.7 -0.7 11/16/2005 11:00:00 9.8 1.6 14.1 6.1 9 1.7 14.1 5.3 7.5 1.6 12.2 4.2 21 12 5 300 -0.6 0 -0.5 -0.7 11/16/2005 11:10:00 9.6 1.7 13.3 4.2 9 1.7 13.7 4.2 7.6 1.7 11.8 2.6 18 12 14 300 -0.7 0 -0.5 -0.7 11/16/2005 11:20:00 10.3 1.7 14.9 4.2 9.5 1.7 14.5 4.2 7.9 1.5 12.2 3.8 22 13 19 300 -0.6 0 -0.5 -0.7 11/16/2005 11:30:00 9.8 1.7 13.7 4.9 9 1.7 13.7 4.6 7.6 1.7 13 3 24 13 32 300 -0.6 0 -0.5 -0.7 11/16/2005 11:40:00 9.7 1.8 15.3 4.6 8.9 1.7 13.3 4.6 7.7 1.6 12.6 3.4 26 13 31 300 -0.5 0 -0.5 -0.5 11/16/2005 11:50:00 9 1.7 13.7 4.9 8.3 1.6 13 4.6 7 1.6 11.5 3.4 29 13 15 300 -0.5 0 -0.3 -0.5 11/16/2005 12:00:00 8.6 1.8 13.7 3.8 8 1.7 13 4.2 6.6 1.7 11.5 1.9 32 14 23 300 -0.3 0 -0.3 -0.5 11/16/2005 12:10:00 9 1.7 13.7 4.9 8.3 1.7 13.7 4.6 6.6 1.5 11.8 2.6 29 13 28 300 -0.2 0 -0.1 -0.3 11/16/2005 12:20:00 8 1.8 13.3 3 7.5 1.7 13.3 3 6.2 1.5 10.3 2.3 33 15 33 300 0 0 0.2 -0.1 11/16/2005 12:30:00 8.1 2 13.3 2.6 7.6 1.9 13 2.3 6 1.8 13 2.3 28 17 17 300 0.1 0 0.2 0.2 11/16/2005 12:40:00 9.2 2.1 14.1 4.6 8.5 2 13.3 4.2 7.1 2 12.2 1.9 25 14 27 300 0.2 0 0.4 0.2 11/16/2005 12:50:00 9.8 1.7 14.5 5.3 9.1 1.7 14.5 5.3 7.4 1.6 13 3.4 27 15 25 300 0.1 0 0.2 -0.1 11/16/2005 13:00:00 9.9 1.7 14.9 4.9 9.1 1.7 13.3 3.8 7.5 1.8 13.3 3.4 27 14 24 300 0 0 0.2 -0.1 11/16/2005 13:10:00 8.8 2 16.1 4.2 8.1 1.9 13.3 3.8 6.7 1.7 11.1 2.6 30 16 17 300 0.1 0 0.2 0.2 11/16/2005 13:20:00 8.3 1.6 11.8 4.2 7.8 1.5 11.8 3.8 6.1 1.5 10.7 2.6 32 16 27 300 0.2 0 0.4 0.2 11/16/2005 13:30:00 7.3 1.7 12.2 3.4 6.7 1.6 12.2 3.4 5.4 1.6 9.9 1.1 33 17 4 300 0.3 0 0.7 0.2 11/16/2005 13:40:00 4.8 1.7 9.5 0.7 4.6 1.5 8.8 1.1 3.6 1.5 7.2 0.4 48 26 44 300 0.7 0 0.7 0.7 11/16/2005 13:50:00 4.5 1.5 8.8 1.1 4.4 1.5 9.1 1.1 4 1.4 9.1 0.7 70 35 37 300 0.7 0 0.9 0.7 11/16/2005 14:00:00 3.7 1.2 6.5 1.1 3.7 1.1 6.8 1.1 3 1.1 6.1 0.7 55 22 31 300 0.7 0 0.9 0.7 11/16/2005 14:10:00 3.3 1.3 6.8 0.7 3.3 1.3 7.2 0.7 2.9 1.3 7.6 0.4 73 29 67 300 0.7 0 0.9 0.7 11/16/2005 14:20:00 3.3 1 6.5 0.4 3.3 1.1 6.8 0.4 3 1 6.8 0.7 71 28 72 300 0.7 0 0.9 0.7 11/16/2005 14:30:00 4 1.1 6.1 1.9 4 1.1 6.5 1.5 3.3 1 6.1 1.1 57 27 92 300 0.8 0 0.9 0.7 11/16/2005 14:40:00 5.1 1.3 8.4 1.9 4.8 1.3 8.8 1.5 3.8 1.3 7.6 0.4 41 18 49 300 0.8 0 0.9 0.9 11/16/2005 14:50:00 4.4 1.3 7.2 0.7 4.2 1.3 6.8 0.7 3.3 1.2 6.5 0.7 48 26 36 300 0.9 0 0.9 0.9 11/16/2005 15:00:00 4.4 1.5 10.3 1.5 4.2 1.4 9.9 0.7 3.5 1.3 8.8 0.7 40 27 27 300 0.8 0 0.9 0.9 11/16/2005 15:10:00 4.4 1.5 8 1.5 4.2 1.3 7.2 1.1 3.5 1.1 7.2 1.5 42 22 26 300 0.8 0 0.9 0.9 11/16/2005 15:20:00 4 1.2 6.5 0.4 3.9 1.2 6.8 0.4 3.3 1.2 6.8 0.7 43 22 36 300 0.8 0 0.9 0.9 11/16/2005 15:30:00 3.3 1.4 6.5 0.4 3.3 1.5 6.8 0.4 2.7 1.2 5.7 0.4 54 26 46 300 0.8 0 0.9 0.9 11/16/2005 15:40:00 2.7 1.2 5.7 0.4 2.6 1.2 5.7 0.4 2.3 1.1 5.3 0.4 54 39 21 300 0.8 0 0.9 0.9 11/16/2005 15:50:00 2.6 0.6 4.2 1.1 2.6 0.7 4.2 1.1 2 0.7 4.2 0.7 64 23 73 300 0.9 0 1.1 0.9 11/16/2005 16:00:00 2.1 0.7 4.2 0.4 2.1 0.7 4.2 0.4 2 0.6 3.8 0.7 58 22 64 300 1.1 0 1.4 0.9 11/16/2005 16:10:00 1.7 0.8 3.4 0.4 1.6 0.8 3.4 0.4 1.2 0.7 3 0.4 43 45 18 300 0.9 0.1 1.4 0.9 11/16/2005 16:20:00 1.5 0.7 3 0.4 1.4 0.7 3.4 0.4 1.5 0.6 3 0.4 88 41 128 300 0.6 0.2 1.1 0.2 11/16/2005 16:30:00 1.9 0.8 3.8 0.4 1.8 0.8 3.4 0.4 2 0.7 3.8 0.4 167 27 178 300 -0.2 0.2 0.2 -0.5 11/16/2005 16:40:00 1.5 0.8 3.4 0.4 1.5 0.8 3.4 0.4 1.5 0.8 3.4 0.4 190 16 179 300 -0.5 0 -0.5 -0.5 11/16/2005 16:50:00 0.7 0.5 1.9 0.4 0.6 0.5 1.9 0.4 0.7 0.5 2.3 0.4 164 45 175 300 -0.6 0 -0.5 -0.7 11/16/2005 17:00:00 1.2 0.5 2.3 0.4 1.1 0.5 2.3 0.4 1.3 0.5 2.3 0.4 168 43 176 300 -0.7 0 -0.5 -0.7 11/16/2005 17:10:00 1.2 0.5 2.6 0.4 1 0.5 2.6 0.4 1.3 0.5 3 0.4 174 32 149 300 -0.9 0 -0.7 -1 11/16/2005 17:20:00 1.6 0.7 3.4 0.4 1.6 0.7 3 0.4 1.5 0.6 2.6 0.4 177 30 187 300 -0.9 0 -0.7 -1 11/16/2005 17:30:00 1.4 0.8 3 0.4 1.4 0.8 3 0.4 1.4 0.7 3 0.4 212 21 237 300 -0.9 0 -0.7 -1 11/16/2005 17:40:00 0.8 0.5 1.9 0.4 0.7 0.5 1.9 0.4 1.1 0.4 1.9 0.4 217 14 217 300 -0.9 0 -0.7 -1 11/16/2005 17:50:00 1.2 0.9 3 0.4 1.2 0.9 3 0.4 1.2 0.8 3 0.4 198 36 179 300 -0.9 0 -0.7 -1 11/16/2005 18:00:00 1.1 0.6 2.6 0.4 1 0.7 2.6 0.4 1 0.7 2.6 0.4 189 21 189 300 -1 0 -0.7 -1 11/16/2005 18:10:00 1.2 0.5 2.3 0.4 1.1 0.5 2.3 0.4 1 0.5 2.3 0.4 224 61 214 300 -1 0 -1 -1.2 11/16/2005 18:20:00 1 0.6 2.6 0.4 0.9 0.6 2.6 0.4 1 0.7 2.6 0.4 166 53 163 300 -1 0 -1 -1 11/16/2005 18:30:00 1.6 0.8 3 0.4 1.6 0.9 3.4 0.4 1.6 0.7 3 0.4 168 58 174 300 -1 0 -1 -1 11/16/2005 18:40:00 1.3 0.6 2.6 0.4 1.2 0.6 2.3 0.4 1.4 0.4 2.6 0.4 189 35 220 300 -1 0 -0.7 -1 11/16/2005 18:50:00 1.5 0.5 2.6 0.4 1.4 0.5 2.6 0.4 1.5 0.5 2.3 0.4 179 13 172 300 -1 0 -0.7 -1 11/16/2005 19:00:00 0.8 0.5 1.9 0.4 0.7 0.4 1.9 0.4 0.7 0.4 1.9 0.4 136 41 181 300 -1 0 -0.7 -1 11/16/2005 19:10:00 1.3 0.6 3 0.4 1.1 0.7 3 0.4 0.7 0.5 3 0.4 47 30 39 300 -0.9 0 -0.7 -1 11/16/2005 19:20:00 1.9 1 4.6 0.4 1.7 1 4.6 0.4 1.5 0.8 3.4 0.4 71 79 30 300 -0.6 0.3 -0.1 -0.7 11/16/2005 19:30:00 1.4 1.1 4.9 0.4 1.4 1.1 5.3 0.4 1.4 0.7 3.8 0.4 116 82 20 300 -0.5 0 -0.1 -0.7 11/16/2005 19:40:00 1.6 1 3.8 0.4 1.5 0.9 3.8 0.4 1.1 0.7 3.4 0.4 99 56 117 300 -0.6 0 -0.5 -0.7 11/16/2005 19:50:00 1.5 1 4.2 0.4 1.4 1 4.2 0.4 1 0.6 3 0.4 95 53 66 300 -0.6 0 -0.5 -0.7 11/16/2005 20:00:00 1.6 0.7 3.8 0.4 1.5 0.8 4.2 0.4 1.2 0.6 3 0.4 67 36 80 300 -0.5 0.1 -0.1 -0.5 11/16/2005 20:10:00 2.6 0.9 4.9 0.4 2.6 0.9 5.3 0.4 2.1 0.8 4.2 0.4 66 24 53 300 -0.1 0.1 0.2 -0.3 11/16/2005 20:20:00 1.9 0.8 3.8 0.4 1.8 0.8 4.2 0.4 1.9 0.8 4.2 0.4 148 72 93 300 -0.2 0.2 0.2 -0.5 11/16/2005 20:30:00 1.9 0.6 3.4 0.4 2 0.5 3.4 0.4 2.1 0.5 3.4 0.7 174 72 187 300 -0.5 0 -0.5 -0.5 11/16/2005 20:40:00 2 0.5 3 0.7 1.9 0.5 3 0.4 1.9 0.5 3 0.7 224 24 262 300 -0.6 0 -0.5 -0.5 11/16/2005 20:50:00 1.7 0.5 2.3 0.4 1.7 0.4 2.6 0.4 1.5 0.4 2.3 0.4 208 19 234 300 -0.6 0 -0.5 -0.5 11/16/2005 21:00:00 1.3 0.5 2.6 0.4 1.3 0.6 2.6 0.4 1.2 0.5 2.3 0.4 190 15 171 300 -0.6 0 -0.5 -0.5 11/16/2005 21:10:00 1.7 0.6 3 0.4 1.8 0.7 3 0.4 1.7 0.6 2.6 0.4 198 24 190 300 -0.6 0 -0.5 -0.5 11/16/2005 21:20:00 1.9 0.5 3 0.4 1.9 0.5 3 0.4 1.6 0.5 2.6 0.4 207 24 187 300 -0.5 0 -0.5 -0.5 11/16/2005 21:30:00 1.5 0.6 3 0.4 1.5 0.6 3 0.4 1.4 0.6 2.6 0.4 198 22 183 300 -0.5 0 -0.5 -0.5 11/16/2005 21:40:00 2 0.7 3 0.4 2 0.6 3 0.4 1.8 0.6 2.6 0.4 200 15 222 300 -0.5 0 -0.5 -0.5 11/16/2005 21:50:00 1.7 0.5 3 0.7 1.9 0.5 3 0.7 1.7 0.5 2.6 0.4 213 18 237 300 -0.5 0 -0.5 -0.5 11/16/2005 22:00:00 1.3 0.6 3 0.4 1.2 0.6 3 0.4 1.1 0.5 2.6 0.4 212 29 272 300 -0.5 0 -0.3 -0.5 11/16/2005 22:10:00 1.1 0.4 2.3 0.4 1 0.5 2.3 0.4 1 0.4 1.9 0.4 207 26 187 300 -0.5 0 -0.3 -0.5 11/16/2005 22:20:00 0.8 0.4 1.9 0.4 0.8 0.4 1.9 0.4 0.8 0.4 1.5 0.4 204 12 186 300 -0.4 0 -0.3 -0.5 11/16/2005 22:30:00 0.7 0.3 1.5 0.4 0.6 0.3 1.5 0.4 0.6 0.3 1.5 0.4 183 24 161 300 -0.4 0 -0.3 -0.5 11/16/2005 22:40:00 0.5 0.4 1.9 0.4 0.5 0.3 1.5 0.4 0.5 0.3 1.9 0.4 184 27 158 300 -0.5 0 -0.3 -0.5 11/16/2005 22:50:00 0.8 0.5 2.3 0.4 0.8 0.5 2.3 0.4 0.8 0.5 1.9 0.4 186 22 164 300 -0.5 0 -0.3 -0.5 11/16/2005 23:00:00 1 0.5 1.9 0.4 0.9 0.5 1.9 0.4 0.9 0.5 2.3 0.4 218 22 233 300 -0.4 0 -0.3 -0.5 11/16/2005 23:10:00 1.2 0.5 2.3 0.4 1 0.6 2.3 0.4 0.9 0.5 1.9 0.4 228 20 216 300 -0.4 0 -0.3 -0.5 11/16/2005 23:20:00 1.8 0.4 2.6 0.7 1.8 0.4 2.6 0.4 1.7 0.4 2.6 0.7 228 12 220 300 -0.4 0 -0.3 -0.5 11/16/2005 23:30:00 2.1 0.4 3 1.1 2 0.4 2.6 0.7 1.7 0.5 2.6 0.4 233 11 219 300 -0.4 0 -0.3 -0.5 11/16/2005 23:40:00 0.9 0.4 1.9 0.4 0.8 0.4 1.5 0.4 0.7 0.4 1.5 0.4 252 12 251 300 -0.3 0 -0.1 -0.5 11/16/2005 23:50:00 0.7 0.4 1.9 0.4 0.7 0.4 1.9 0.4 0.7 0.4 1.9 0.4 233 35 194 300 -0.3 0 -0.3 -0.5 11/17/2005 00:00:00 1.7 0.4 2.6 0.7 1.8 0.4 3 1.1 1.8 0.4 2.6 1.1 211 10 220 300 -0.3 0 -0.3 -0.5 11/17/2005 00:10:00 1.5 0.6 2.6 0.4 1.8 0.7 3 0.4 1.5 0.8 2.6 0.4 209 8 195 300 -0.3 0 -0.3 -0.5 11/17/2005 00:20:00 1.6 0.5 2.6 0.7 1.6 0.4 2.6 0.4 1.3 0.4 2.3 0.4 229 13 250 300 -0.3 0 -0.3 -0.5 11/17/2005 00:30:00 1.1 0.5 2.3 0.4 1 0.5 2.3 0.4 1 0.4 1.9 0.4 237 17 240 300 -0.3 0 -0.1 -0.5 11/17/2005 00:40:00 0.9 0.5 2.3 0.4 0.8 0.5 2.3 0.4 0.8 0.4 1.9 0.4 235 32 293 300 -0.3 0 -0.1 -0.5 11/17/2005 00:50:00 1.2 0.5 2.3 0.4 1.1 0.4 1.9 0.4 1 0.3 1.5 0.4 225 15 242 300 -0.3 0 -0.1 -0.5 11/17/2005 01:00:00 1.2 0.4 2.6 0.4 1.2 0.4 2.3 0.4 1.1 0.5 2.3 0.4 219 15 188 300 -0.3 0 -0.1 -0.3 11/17/2005 01:10:00 0.9 0.5 1.9 0.4 0.8 0.4 1.5 0.4 0.7 0.4 1.5 0.4 222 22 219 300 -0.3 0 -0.1 -0.3 11/17/2005 01:20:00 1 0.5 1.9 0.4 0.9 0.4 1.5 0.4 0.9 0.5 1.9 0.4 193 11 183 300 -0.3 0 -0.3 -0.5 11/17/2005 01:30:00 1 0.4 1.9 0.4 0.9 0.5 1.9 0.4 0.9 0.5 1.9 0.4 194 5 187 300 -0.3 0 -0.1 -0.5 11/17/2005 01:40:00 0.8 0.3 1.5 0.4 0.7 0.3 1.5 0.4 0.7 0.4 1.5 0.4 201 4 200 300 -0.3 0 -0.1 -0.5 11/17/2005 01:50:00 2.1 0.6 3.4 0.7 2.1 0.5 3.4 1.1 1.9 0.4 3 1.1 216 6 233 300 -0.3 0 -0.3 -0.5 11/17/2005 02:00:00 2.2 0.6 3.4 0.4 2.2 0.6 3.4 0.4 1.8 0.7 3 0.4 233 7 233 300 -0.3 0 -0.3 -0.5 11/17/2005 02:10:00 2.3 0.3 2.6 1.5 2.2 0.3 2.6 1.5 1.8 0.4 2.6 0.7 239 7 246 300 -0.3 0 -0.3 -0.5 11/17/2005 02:20:00 1.6 0.5 2.3 0.4 1.4 0.5 2.3 0.4 1.2 0.5 2.3 0.4 236 9 249 300 -0.3 0 -0.1 -0.5 11/17/2005 02:30:00 1.4 0.9 3.8 0.4 1.3 1 3.8 0.4 1.1 0.8 3.4 0.4 223 7 239 300 -0.3 0 -0.1 -0.3 11/17/2005 02:40:00 1.3 0.9 3.4 0.4 1.2 0.9 3.4 0.4 1 0.7 3 0.4 244 14 237 300 -0.3 0 -0.1 -0.3 11/17/2005 02:50:00 2.3 0.4 3 1.1 2.1 0.4 3 0.7 2.1 0.4 3 1.1 233 8 229 300 -0.2 0 -0.1 -0.3 11/17/2005 03:00:00 2 0.5 3 0.7 1.9 0.5 3 0.4 1.7 0.5 2.6 0.4 252 12 238 300 -0.2 0 -0.1 -0.1 11/17/2005 03:10:00 2.1 0.4 3 1.1 2 0.4 2.6 1.1 1.9 0.3 3 0.7 260 5 254 300 -0.2 0 -0.1 -0.1 11/17/2005 03:20:00 1.7 0.5 2.6 0.7 1.5 0.5 2.6 0.7 1.4 0.5 2.6 0.4 265 8 268 300 -0.1 0 -0.1 -0.1 11/17/2005 03:30:00 1.9 0.4 3 1.1 1.7 0.5 3 0.7 1.6 0.4 2.6 0.7 253 9 247 300 -0.2 0 -0.1 -0.1 11/17/2005 03:40:00 2.3 0.4 3.4 1.5 2.2 0.4 3.4 1.1 1.9 0.5 3.4 0.7 234 6 241 300 -0.2 0 -0.1 -0.3 11/17/2005 03:50:00 1.5 0.8 3.4 0.4 1.4 0.8 3 0.4 1.3 0.7 3 0.4 239 8 246 300 -0.1 0 -0.1 -0.1 11/17/2005 04:00:00 1.2 0.4 2.3 0.4 1 0.4 1.9 0.4 0.8 0.3 1.5 0.4 242 7 239 300 -0.1 0 0.2 -0.1 11/17/2005 04:10:00 1 0.5 2.6 0.4 0.8 0.5 2.3 0.4 0.7 0.4 1.9 0.4 268 13 297 300 -0.1 0 -0.1 -0.1 11/17/2005 04:20:00 1.1 0.4 1.9 0.4 0.8 0.4 1.9 0.4 0.6 0.3 1.5 0.4 253 11 265 300 -0.1 0 -0.1 -0.1 11/17/2005 04:30:00 1.2 0.5 2.3 0.4 1 0.5 2.3 0.4 1 0.5 1.9 0.4 252 8 248 300 -0.1 0 0.2 -0.1 11/17/2005 04:40:00 1.8 0.3 2.6 0.7 1.7 0.3 2.6 0.7 1.5 0.4 2.3 0.4 248 7 250 300 0 0 0.2 -0.1 11/17/2005 04:50:00 2.4 0.4 3.4 1.5 2.3 0.4 3.4 1.1 2 0.5 3 1.1 265 10 268 300 0.1 0 0.2 -0.1 11/17/2005 05:00:00 2.2 0.6 3.4 0.7 2.1 0.5 3.4 0.7 1.7 0.6 3 0.4 262 12 250 300 0.1 0 0.2 -0.1 11/17/2005 05:10:00 1.7 0.3 2.3 1.1 1.6 0.3 2.3 0.7 1.4 0.4 2.3 0.4 255 9 270 300 0.1 0 0.2 -0.1 11/17/2005 05:20:00 1.9 0.3 3 1.1 1.8 0.3 2.6 1.1 1.8 0.3 2.6 1.1 265 10 258 300 0.1 0 0.2 -0.1 11/17/2005 05:30:00 1.3 0.4 2.3 0.4 1 0.4 2.3 0.4 0.7 0.4 1.9 0.4 285 11 297 300 0.1 0 0.2 0.2 11/17/2005 05:40:00 1 0.3 1.5 0.4 0.7 0.3 1.5 0.4 0.6 0.2 1.1 0.4 257 15 251 300 0.1 0 0.2 0.2 11/17/2005 05:50:00 1.5 0.3 1.9 0.7 1.2 0.4 1.9 0.4 1.2 0.3 1.9 0.4 282 10 285 300 0.2 0 0.2 0.2 11/17/2005 06:00:00 1.1 0.4 2.3 0.4 0.9 0.5 1.9 0.4 0.8 0.4 1.9 0.4 280 2 277 300 0.3 0 0.4 0.2 11/17/2005 06:10:00 0.6 0.3 1.5 0.4 0.5 0.2 1.1 0.4 0.4 0.2 1.1 0.4 281 2 283 300 0.4 0 0.7 0.2 11/17/2005 06:20:00 1 0.6 1.9 0.4 0.9 0.5 1.9 0.4 1 0.5 1.9 0.4 254 17 246 300 0.3 0 0.7 0.2 11/17/2005 06:30:00 1.4 0.6 2.6 0.4 1.3 0.6 2.6 0.4 1.2 0.5 2.3 0.4 238 14 254 300 0.2 0 0.4 0.2 11/17/2005 06:40:00 2.1 0.7 3.8 0.4 2 0.7 3.4 0.4 1.9 0.7 3.4 0.4 230 18 237 300 0.2 0 0.2 0.2 11/17/2005 06:50:00 0.9 0.5 2.3 0.4 0.7 0.5 2.3 0.4 0.6 0.4 2.3 0.4 278 33 232 300 0.1 0 0.2 0.2 11/17/2005 07:00:00 2.4 0.4 3.4 1.5 2.3 0.4 3 1.5 2.1 0.4 2.6 1.1 234 6 240 300 0.1 0 0.2 0.2 11/17/2005 07:10:00 1.7 0.9 3 0.4 1.6 0.9 3 0.4 1.5 0.8 3 0.4 230 6 220 300 0.1 0 0.2 0.2 11/17/2005 07:20:00 1.3 0.7 2.3 0.4 1.1 0.6 2.3 0.4 1.1 0.6 1.9 0.4 256 15 268 300 0.1 0 0.2 0.2 11/17/2005 07:30:00 0.8 0.5 2.3 0.4 0.7 0.5 1.9 0.4 0.6 0.4 1.9 0.4 266 5 275 300 0.1 0 0.2 -0.1 11/17/2005 07:40:00 0.4 0.1 0.7 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 295 12 266 300 0.1 0 0.2 -0.1 11/17/2005 07:50:00 0.8 0.3 1.5 0.4 0.6 0.2 1.1 0.4 0.5 0.2 1.1 0.4 318 10 309 300 0 0 0.2 -0.1 11/17/2005 08:00:00 0.4 0.2 1.1 0.4 0.4 0.1 1.1 0.4 0.4 0 0.7 0.4 340 2 332 300 -0.1 0 0.2 -0.1 11/17/2005 08:10:00 0.7 0.3 1.1 0.4 0.4 0.2 1.1 0.4 0.4 0.1 0.7 0.4 301 1 306 300 0.1 0 0.2 -0.1 11/17/2005 08:20:00 0.9 0.4 1.5 0.4 0.7 0.3 1.5 0.4 0.7 0.3 1.5 0.4 267 28 271 300 0.1 0 0.2 -0.1 11/17/2005 08:30:00 1 0.4 1.9 0.4 1 0.5 1.9 0.4 1.3 0.3 1.9 0.7 207 6 196 300 0 0 0.2 -0.1 11/17/2005 08:40:00 1.8 0.6 2.6 0.4 1.6 0.6 2.6 0.4 1.7 0.6 2.6 0.4 226 6 232 300 0 0 0.2 -0.1 11/17/2005 08:50:00 1.2 0.5 2.3 0.4 1.1 0.4 1.9 0.4 0.9 0.4 1.9 0.4 224 3 219 300 0.1 0 0.2 -0.1 11/17/2005 09:00:00 1.6 0.8 2.6 0.4 1.5 0.8 2.6 0.4 1.2 0.7 2.6 0.4 240 15 222 300 0.1 0 0.2 -0.1 11/17/2005 09:10:00 1.8 0.6 3 0.4 1.6 0.7 3 0.4 1.5 0.7 2.6 0.4 234 9 246 300 0.1 0 0.2 -0.1 11/17/2005 09:20:00 2.3 0.5 3.4 1.1 2.2 0.5 3.4 1.1 1.7 0.6 3 0.4 251 8 254 300 0.1 0 0.2 -0.1 11/17/2005 09:30:00 1.6 0.6 2.6 0.4 1.4 0.6 2.6 0.4 1.1 0.6 2.6 0.4 237 11 246 300 0.1 0 0.2 0.2 11/17/2005 09:40:00 1.9 0.3 2.3 0.4 1.9 0.3 2.3 1.1 1.8 0.4 2.3 0.7 224 8 222 300 0.1 0 0.2 0.2 11/17/2005 09:50:00 1.3 0.5 2.3 0.4 1.2 0.5 2.3 0.4 1.3 0.5 2.6 0.4 220 15 247 300 0.1 0 0.2 0.2 11/17/2005 10:00:00 1.1 0.3 1.9 0.4 1 0.3 1.9 0.4 1 0.4 1.9 0.4 223 16 208 300 0.1 0 0.2 0.2 11/17/2005 10:10:00 1.2 0.5 2.3 0.4 1.4 0.5 2.6 0.4 1.2 0.5 2.3 0.4 210 6 213 300 0.1 0 0.2 0.2 11/17/2005 10:20:00 1.7 0.4 2.6 0.7 1.7 0.4 2.6 0.7 1.5 0.4 2.6 0.4 227 9 220 300 0.2 0 0.2 0.2 11/17/2005 10:30:00 1.2 0.4 2.3 0.4 1.3 0.4 2.3 0.4 1.3 0.4 1.9 0.4 216 7 218 300 0.2 0 0.2 0.2 11/17/2005 10:40:00 0.8 0.4 1.9 0.4 0.6 0.4 1.5 0.4 0.6 0.4 1.5 0.4 326 28 321 300 0.2 0 0.4 0.2 11/17/2005 10:50:00 0.4 0.1 0.7 0.4 0.4 0 0.4 0.4 0.4 0.2 1.1 0.4 324 69 353 300 0.4 0 0.4 0.2 11/17/2005 11:00:00 0.4 0 0.7 0.4 0.4 0 0.4 0.4 0.4 0.1 0.7 0.4 178 6 182 300 0.5 0 0.7 0.2 11/17/2005 11:10:00 1.2 0.4 1.9 0.4 1.2 0.4 1.9 0.4 1 0.4 1.9 0.4 216 8 214 300 0.5 0 0.7 0.4 11/17/2005 11:20:00 2.2 0.4 2.6 0.4 2.1 0.4 2.6 0.4 2 0.5 2.6 0.4 229 7 226 300 0.5 0 0.7 0.7 11/17/2005 11:30:00 2.1 0.6 4.2 1.1 2 0.6 3.8 0.7 1.8 0.6 4.2 0.4 226 11 224 300 0.7 0 0.7 0.7 11/17/2005 11:40:00 3.1 0.7 4.6 0.7 3.1 0.7 4.2 0.7 2.6 0.7 4.2 0.7 229 11 229 300 0.7 0 0.7 0.7 11/17/2005 11:50:00 3.5 0.6 4.9 1.9 3.5 0.6 4.6 1.9 2.9 0.7 4.6 1.1 233 11 214 300 0.7 0 0.9 0.7 11/17/2005 12:00:00 2.9 0.9 5.3 0.7 2.8 0.9 5.3 0.7 2.2 0.8 4.6 0.7 232 14 235 300 0.8 0 0.9 0.7 11/17/2005 12:10:00 2.7 0.7 4.6 1.1 2.7 0.7 4.2 0.7 2.2 0.6 3.8 0.4 242 14 256 300 0.9 0 0.9 0.9 11/17/2005 12:20:00 2.4 0.5 3.4 1.1 2.3 0.5 3.8 1.5 2.1 0.5 3.4 0.7 256 11 252 300 1 0 1.4 0.9 11/17/2005 12:30:00 0.9 0.4 1.9 0.4 0.7 0.4 1.9 0.4 0.9 0.4 1.9 0.4 256 13 264 300 1.2 0 1.4 0.9 11/17/2005 12:40:00 1.4 0.4 2.3 0.4 1.3 0.5 1.9 0.4 1.3 0.5 2.3 0.4 230 10 222 300 1.2 0 1.4 1.1 11/17/2005 12:50:00 1.2 0.4 2.3 0.4 1 0.5 2.3 0.4 0.9 0.5 1.9 0.4 226 8 227 300 1.2 0 1.4 1.1 11/17/2005 13:00:00 0.5 0.2 1.1 0.4 0.4 0.1 0.7 0.4 0.4 0.1 0.7 0.4 251 7 240 300 1.2 0 1.4 1.1 11/17/2005 13:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 252 10 300 300 1.3 0 1.6 1.4 11/17/2005 13:20:00 0.4 0.1 0.7 0.4 0.4 0 0.4 0.4 0.5 0.2 1.1 0.4 179 22 174 300 1.4 0 1.6 1.4 11/17/2005 13:30:00 1 0.4 1.9 0.4 0.8 0.4 1.5 0.4 1 0.4 1.9 0.4 97 26 77 300 1.4 0 1.6 1.4 11/17/2005 13:40:00 1.6 0.5 2.3 0.4 1.4 0.5 2.3 0.4 1.5 0.5 2.3 0.4 82 7 77 300 1.4 0 1.6 1.4 11/17/2005 13:50:00 1.3 0.4 2.3 0.4 1.2 0.4 1.9 0.4 1.2 0.5 2.3 0.4 72 9 75 300 1.5 0 1.6 1.4 11/17/2005 14:00:00 0.8 0.3 1.5 0.4 0.7 0.3 1.1 0.4 0.8 0.4 1.5 0.4 60 8 63 300 1.5 0 1.6 1.4 11/17/2005 14:10:00 1.3 0.5 2.3 0.4 1.2 0.5 2.3 0.4 1.1 0.4 2.3 0.4 59 6 62 300 1.5 0 1.6 1.4 11/17/2005 14:20:00 1.4 0.5 2.6 0.4 1.3 0.6 2.3 0.4 1.2 0.6 2.3 0.4 52 15 64 300 1.6 0 1.8 1.6 11/17/2005 14:30:00 1.2 0.4 1.9 0.4 1 0.4 1.9 0.4 1 0.4 1.9 0.4 41 9 18 300 1.8 0 1.8 1.6 11/17/2005 14:40:00 1 0.3 1.5 0.4 0.8 0.3 1.5 0.4 0.8 0.3 1.5 0.4 25 10 41 300 1.7 0 1.8 1.6 11/17/2005 14:50:00 1.6 0.3 2.3 1.1 1.4 0.3 2.3 0.7 1.4 0.4 2.3 0.7 34 5 40 300 1.7 0 1.8 1.6 11/17/2005 15:00:00 2.4 0.7 3.8 1.1 2.3 0.7 3.8 0.7 1.7 0.7 3.4 0.4 38 10 32 300 1.8 0 1.8 1.6 11/17/2005 15:10:00 2.2 1.1 4.2 0.4 2.1 1.1 4.2 0.4 1.7 1 3.4 0.4 23 22 28 300 1.8 0 1.8 1.8 11/17/2005 15:20:00 2.2 1.2 4.2 0.4 2.2 1.2 4.2 0.4 1.8 1 3.8 0.4 36 6 36 300 1.8 0 1.8 1.8 11/17/2005 15:30:00 2.1 0.5 3.4 0.7 2 0.6 3.4 0.7 1.7 0.6 3 0.7 34 0 34 300 1.9 0 2.1 1.8 11/17/2005 15:40:00 1.4 0.6 2.6 0.4 1.4 0.7 2.6 0.4 1.2 0.6 2.3 0.4 34 0 35 300 1.8 0 1.8 1.8 11/17/2005 15:50:00 1.2 0.4 1.9 0.4 1.2 0.4 1.9 0.4 1 0.6 1.9 0.4 34 0 34 300 1.8 0 1.8 1.8 11/17/2005 16:00:00 2.1 0.4 2.6 1.1 2.1 0.4 3 0.7 1.5 0.4 2.3 0.4 34 0 34 300 1.8 0 1.8 1.8 11/17/2005 16:10:00 1.5 0.5 2.6 0.4 1.5 0.6 2.6 0.4 1 0.6 2.6 0.4 34 0 34 300 1.8 0 1.8 1.8 11/17/2005 16:20:00 1.4 0.4 2.3 0.4 1.4 0.4 2.6 0.4 0.9 0.4 2.3 0.4 34 0 34 300 1.8 0 1.8 1.8 11/17/2005 16:30:00 1.2 0.7 2.6 0.4 1.2 0.7 2.6 0.4 0.9 0.6 2.3 0.4 34 0 34 300 1.8 0 1.8 1.8 11/17/2005 16:40:00 1.9 0.5 3 0.4 2 0.5 3.4 0.4 1.4 0.5 2.6 0.4 34 0 34 300 1.8 0 1.8 1.8 11/17/2005 16:50:00 2.2 0.6 3.4 0.4 2.2 0.6 3.4 0.7 1.7 0.6 3 0.4 34 0 34 300 1.8 0 2.1 1.8 11/17/2005 17:00:00 1.4 0.4 2.3 0.4 1.3 0.4 2.3 0.4 1 0.4 1.9 0.4 34 0 34 300 1.9 0 2.1 1.8 11/17/2005 17:10:00 0.8 0.5 2.3 0.4 0.8 0.5 2.3 0.4 0.7 0.4 1.9 0.4 34 0 34 300 1.9 0 2.1 1.8 11/17/2005 17:20:00 0.4 0.2 1.1 0.4 0.4 0.2 1.1 0.4 0.4 0.1 1.1 0.4 34 0 34 300 1.9 0 2.1 1.8 11/17/2005 17:30:00 0.6 0.4 1.9 0.4 0.6 0.4 1.9 0.4 0.6 0.4 1.9 0.4 34 0 34 300 1.8 0 1.8 1.8 11/17/2005 17:40:00 1.8 0.3 2.3 1.1 1.8 0.3 2.6 0.7 1.5 0.4 2.3 0.4 34 0 34 300 1.8 0 1.8 1.8 11/17/2005 17:50:00 1.6 0.4 2.6 0.7 1.6 0.4 2.6 0.7 1.4 0.4 2.3 0.4 34 0 34 300 1.8 0 2.1 1.8 11/17/2005 18:00:00 2.5 0.4 3.4 1.1 2.5 0.4 3.4 1.1 1.9 0.4 3 0.7 34 0 34 300 1.9 0 2.1 1.8 11/17/2005 18:10:00 1.8 0.8 3 0.4 1.7 0.8 3 0.4 1.2 0.6 2.3 0.4 34 0 34 300 2 0 2.3 1.8 11/17/2005 18:20:00 0.9 0.4 1.9 0.4 0.7 0.4 1.5 0.4 0.5 0.3 1.5 0.4 34 0 34 300 2 0 2.1 1.8 11/17/2005 18:30:00 1.5 0.4 2.6 0.4 1.3 0.4 2.3 0.4 0.8 0.3 1.5 0.4 34 0 34 300 2 0 2.1 1.8 11/17/2005 18:40:00 1.5 0.5 2.3 0.4 1.4 0.6 2.3 0.4 0.8 0.4 1.9 0.4 34 0 34 300 2 0 2.1 1.8 11/17/2005 18:50:00 2 0.4 2.6 0.4 1.7 0.4 2.6 0.4 1.1 0.4 2.3 0.4 34 0 34 300 2 0 2.3 1.8 11/17/2005 19:00:00 0.7 0.6 2.3 0.4 0.6 0.4 2.3 0.4 0.5 0.3 1.5 0.4 34 0 34 300 2.1 0 2.3 2.1 11/17/2005 19:10:00 2.1 1 3.8 0.4 2 1 3.4 0.4 1.5 0.8 3 0.4 30 4 25 300 2 0 2.3 1.8 11/17/2005 19:20:00 2.5 0.9 3.8 0.4 2.4 1 3.8 0.4 1.3 0.5 2.6 0.4 16 10 11 300 1.8 0 2.1 1.8 11/17/2005 19:30:00 2.2 0.6 3.4 0.7 2.3 0.6 3.4 0.7 2.2 0.4 3 1.1 62 6 59 300 2 0 2.3 1.8 11/17/2005 19:40:00 2.5 0.4 3.4 1.5 2.5 0.4 3.4 1.5 2.2 0.5 3 1.1 72 6 75 300 2.1 0 2.3 2.1 11/17/2005 19:50:00 2.2 0.5 3 1.1 2.2 0.5 3 0.7 1.7 0.5 2.6 0.7 63 7 73 300 2 0 2.3 2.1 11/17/2005 20:00:00 2.3 0.4 3 1.1 2.3 0.4 3 1.1 1.8 0.4 2.6 0.7 74 8 70 300 2.1 0 2.3 2.1 11/17/2005 20:10:00 2.3 0.5 3.8 1.5 2.3 0.5 3.8 1.5 1.6 0.5 3 0.4 70 6 72 300 2.1 0 2.3 2.1 11/17/2005 20:20:00 2.7 0.5 3.4 0.7 2.8 0.5 3.4 1.1 1.9 0.5 3 0.7 70 8 73 300 2.2 0 2.3 2.1 11/17/2005 20:30:00 2.2 0.7 3.4 0.7 2.3 0.7 3.4 0.7 1.2 0.7 2.6 0.4 64 8 65 300 2.1 0 2.3 2.1 11/17/2005 20:40:00 1.4 0.4 2.3 0.4 1.3 0.4 2.3 0.4 1 0.4 1.9 0.4 102 13 108 300 2.2 0 2.3 2.1 11/17/2005 20:50:00 1.1 0.4 2.3 0.4 1.1 0.4 2.3 0.4 0.8 0.4 1.9 0.4 76 22 113 300 2.1 0 2.3 2.1 11/17/2005 21:00:00 2 0.5 3 0.7 2 0.6 3.4 0.7 1.5 0.7 2.6 0.4 47 6 50 300 2 0 2.3 1.8 11/17/2005 21:10:00 2.4 0.3 3.4 1.9 2.5 0.3 3.4 1.9 2.1 0.3 3 1.1 51 5 63 300 2 0 2.3 1.8 11/17/2005 21:20:00 2.4 0.3 3 1.5 2.4 0.3 3 1.9 1.9 0.4 2.6 0.4 49 5 54 300 2.1 0 2.3 2.1 11/17/2005 21:30:00 2.7 0.3 3.4 1.9 2.8 0.3 3.4 1.9 2.1 0.4 3 1.1 42 4 44 300 2.2 0 2.3 2.1 11/17/2005 21:40:00 2.7 0.5 3.4 1.5 2.7 0.5 3.4 1.5 2.3 0.4 3 1.1 55 8 57 300 2.3 0 2.3 2.3 11/17/2005 21:50:00 2.3 0.4 3.4 1.5 2.4 0.4 3.8 1.5 1.9 0.5 3 1.1 42 7 52 300 2.3 0 2.6 2.3 11/17/2005 22:00:00 1.9 0.4 2.6 1.1 1.9 0.4 3 1.1 1.4 0.4 2.3 0.7 45 11 42 300 2.5 0 2.6 2.3 11/17/2005 22:10:00 1.8 0.5 2.6 0.7 1.8 0.5 3 0.7 1.1 0.4 2.3 0.4 36 7 42 300 2.5 0 2.6 2.6 11/17/2005 22:20:00 1.8 0.3 2.6 0.4 1.9 0.3 2.6 0.4 1.4 0.4 2.3 0.7 48 9 42 300 2.6 0 2.8 2.3 11/17/2005 22:30:00 1 0.4 1.9 0.4 1 0.5 1.9 0.4 0.9 0.5 1.9 0.4 61 22 49 300 2.3 0.1 2.8 2.1 11/17/2005 22:40:00 0.5 0.2 1.5 0.4 0.5 0.2 1.1 0.4 1.2 0.4 1.9 0.4 318 53 299 300 2 0 2.3 1.8 11/17/2005 22:50:00 1 0.3 1.9 0.4 1 0.3 1.9 0.4 1.7 0.3 2.6 1.1 295 7 290 300 2.1 0 2.3 1.8 11/17/2005 23:00:00 1.5 0.6 2.3 0.4 1.5 0.6 2.3 0.4 1.4 0.5 2.3 0.4 315 23 331 300 2.1 0.1 2.3 1.8 11/17/2005 23:10:00 1.7 0.6 3 0.4 1.6 0.6 3 0.4 1.3 0.4 2.3 0.4 286 17 306 300 1.8 0 2.1 1.8 11/17/2005 23:20:00 1 0.5 1.9 0.4 1 0.4 1.9 0.4 0.9 0.4 1.5 0.4 286 11 295 300 1.6 0 1.8 1.4 11/17/2005 23:30:00 1.3 0.5 2.3 0.4 1.3 0.5 2.3 0.4 1 0.5 1.9 0.4 266 16 287 300 1.4 0 1.6 1.4 11/17/2005 23:40:00 0.4 0.1 0.7 0.4 0.4 0.1 0.7 0.4 0.4 0.1 0.7 0.4 238 1 238 300 1.4 0 1.6 1.4 11/17/2005 23:50:00 0.6 0.4 1.5 0.4 0.6 0.3 1.5 0.4 0.4 0 0.4 0.4 256 2 255 300 1.1 0 1.4 0.9 11/18/2005 00:00:00 0.6 0.4 1.5 0.4 0.6 0.4 1.5 0.4 0.5 0.2 1.1 0.4 262 8 253 300 1.4 0 1.6 1.4 11/18/2005 00:10:00 0.4 0.3 1.5 0.4 0.4 0.2 1.5 0.4 0.4 0.2 1.1 0.4 246 0 246 300 1.2 0 1.6 1.1 11/18/2005 00:20:00 0.9 0.5 1.9 0.4 0.8 0.5 1.9 0.4 0.9 0.4 1.9 0.4 245 2 246 300 1.3 0.1 1.6 1.1 11/18/2005 00:30:00 1.1 0.3 1.9 0.4 1.1 0.3 1.9 0.4 1.1 0.3 1.5 0.4 241 21 237 300 1.3 0 1.6 1.1 11/18/2005 00:40:00 0.5 0.2 1.1 0.4 0.6 0.2 1.1 0.4 0.7 0.3 1.5 0.4 214 15 203 300 1 0 1.4 0.9 11/18/2005 00:50:00 1.3 0.4 1.9 0.4 1.1 0.4 1.9 0.4 1.5 0.3 1.9 0.7 240 6 234 300 0.9 0 1.1 0.9 11/18/2005 01:00:00 0.8 0.3 1.5 0.4 0.7 0.3 1.5 0.4 0.9 0.4 1.5 0.4 264 13 265 300 1.1 0 1.4 0.9 11/18/2005 01:10:00 1.7 0.8 3 0.4 1.6 0.8 3 0.4 1.6 0.6 2.6 0.4 144 64 114 300 0.9 0.2 1.4 0.7 11/18/2005 01:20:00 0.5 0.4 1.9 0.4 0.5 0.3 1.9 0.4 0.5 0.3 1.5 0.4 86 1 91 300 0.5 0.2 1.1 0.2 11/18/2005 01:30:00 1.8 0.5 3 0.4 1.8 0.6 3 0.4 2.1 0.6 3.4 0.7 53 30 65 300 0.8 0.2 0.9 0.2 11/18/2005 01:40:00 1.7 0.5 2.6 0.4 1.7 0.6 3 0.4 1.9 0.6 3 0.4 32 35 353 300 0.8 0 1.1 0.7 11/18/2005 01:50:00 2.8 0.5 4.2 1.9 2.8 0.5 4.2 1.9 2.7 0.4 3.8 1.9 59 12 74 300 1 0 1.1 0.9 11/18/2005 02:00:00 2.7 0.7 4.2 1.5 2.7 0.7 4.2 1.1 2.1 0.7 3.8 0.7 64 16 75 300 1 0 1.4 0.9 11/18/2005 02:10:00 2.2 0.6 3.8 0.7 2.2 0.6 3.4 0.7 1.7 0.6 3 0.7 56 12 69 300 1.1 0 1.4 0.9 11/18/2005 02:20:00 1.5 1 3 0.4 1.6 1 3.4 0.4 1.3 1 3 0.4 61 15 51 300 1.2 0 1.4 1.4 11/18/2005 02:30:00 1 0.6 2.3 0.4 1.1 0.5 2.3 0.4 1.1 0.4 1.9 0.4 63 22 79 300 1.2 0 1.4 1.1 11/18/2005 02:40:00 0.9 0.5 1.9 0.4 0.8 0.4 1.9 0.4 0.8 0.5 1.5 0.4 40 22 36 300 1.1 0 1.4 0.9 11/18/2005 02:50:00 2 1.9 5.3 0.4 2 1.9 5.3 0.4 1.8 1.7 5.3 0.4 357 53 315 300 1.4 0.1 1.6 1.1 11/18/2005 03:00:00 4 0.8 5.3 0.7 3.9 0.8 5.3 0.7 3.7 0.7 5.3 1.9 33 39 351 300 2.1 0.5 2.8 1.4 11/18/2005 03:10:00 2.3 1 5.3 0.4 2.3 1 5.3 0.4 2.2 1 4.9 0.4 44 41 346 300 2.9 0 3 2.8 11/18/2005 03:20:00 2.7 0.6 3.8 0.7 2.7 0.6 4.2 0.7 2.2 0.6 3.4 0.4 32 21 11 300 2.4 0.1 2.8 2.3 11/18/2005 03:30:00 3 0.8 4.9 1.1 2.8 0.8 4.6 1.1 2 0.7 3.4 0.4 23 15 18 300 2.4 0.1 2.6 2.3 11/18/2005 03:40:00 3.4 0.7 4.9 0.4 3.4 0.7 4.9 0.7 2.2 0.8 4.2 0.4 42 15 66 300 2.9 0.1 3.3 2.6 11/18/2005 03:50:00 3.6 0.6 4.9 2.3 3.7 0.6 4.9 2.3 2.9 0.6 4.6 1.5 58 9 65 300 3.6 0.1 3.8 3.3 11/18/2005 04:00:00 5.6 1.7 10.3 2.3 5.7 1.8 10.7 2.3 4.4 1.8 9.5 1.1 66 17 93 300 3.9 0.4 5 3.5 11/18/2005 04:10:00 7.5 1.6 11.5 4.2 7.6 1.6 11.5 4.2 6.5 1.3 10.3 2.6 83 13 84 300 5.7 0.3 6 5 11/18/2005 04:20:00 6.8 1.7 11.1 2.6 6.9 1.7 11.1 2.6 5.9 1.5 9.9 2.6 81 17 109 300 6.2 0 6.5 6 11/18/2005 04:30:00 8.2 1.6 12.6 4.2 8.2 1.6 12.6 3.8 7.3 1.5 12.6 3.8 90 13 132 300 6.4 0 6.7 6.2 11/18/2005 04:40:00 7.2 1.4 10.7 4.2 7.3 1.4 10.3 4.2 6.6 1.4 10.3 3.4 89 13 103 300 6.4 0 6.7 6.2 11/18/2005 04:50:00 6 1.6 9.9 2.3 6 1.6 9.9 2.6 5.4 1.5 9.5 2.3 85 16 82 300 6.7 0 7 6.7 11/18/2005 05:00:00 5.4 1.2 8.4 2.6 5.5 1.2 8.4 2.3 4.8 1.5 8.8 1.5 67 19 94 300 6.8 0 7 6.7 11/18/2005 05:10:00 4.4 0.9 6.5 1.9 4.2 0.9 6.5 1.9 3.2 1 6.1 1.1 11 15 18 300 5.7 0.5 6.7 5 11/18/2005 05:20:00 4.4 1.2 8 1.9 4.2 1.3 8 1.5 3.3 1.1 7.2 1.1 57 24 77 300 5.3 0.3 6 5 11/18/2005 05:30:00 4.9 1.3 8.4 2.3 4.7 1.4 8.8 1.5 3.3 1.3 6.5 0.7 47 17 48 300 6.3 0.1 6.7 6.2 11/18/2005 05:40:00 5 1.1 8.4 1.9 4.7 1.2 8.4 2.3 3.7 1.1 6.8 0.7 40 15 44 300 5.9 0.1 6.2 5.7 11/18/2005 05:50:00 5.5 1.8 11.5 1.1 5.6 1.9 11.1 1.1 4.6 1.7 9.5 0.7 71 22 76 300 6.2 0.6 7.3 5.5 11/18/2005 06:00:00 8.5 1.6 12.6 4.2 8.6 1.7 13.3 4.6 7.5 1.5 12.2 4.6 79 11 100 300 7.6 0 7.8 7.3 11/18/2005 06:10:00 8.3 1.3 11.8 4.6 8.4 1.4 12.6 5.3 7.2 1.5 11.8 4.2 75 12 63 300 7.8 0 8 7.8 11/18/2005 06:20:00 6.2 1.7 11.8 3 6.1 1.7 11.8 2.3 5 1.7 11.1 1.5 55 20 81 300 7.7 0.1 7.8 7.3 11/18/2005 06:30:00 6.6 1.7 11.8 3 6.5 1.7 12.2 3 5 1.7 9.9 1.1 53 18 43 300 7.1 0.1 7.3 7 11/18/2005 06:40:00 8.5 2.4 14.1 2.6 8.6 2.5 14.1 2.3 7.1 2.3 13.3 2.6 65 19 67 300 7.8 0.2 8.3 7.3 11/18/2005 06:50:00 9.5 2 14.5 4.9 9.6 2.2 14.9 4.2 7.5 2.1 14.5 3 61 17 46 300 8.1 0 8.3 8 11/18/2005 07:00:00 10.6 2.5 17.2 4.9 10.8 2.6 17.6 5.3 8.9 2.5 15.3 3.8 65 16 59 300 8.3 0.1 8.5 8 11/18/2005 07:10:00 12.9 2.8 22.1 5.7 13 2.9 22.9 4.9 11 2.8 17.6 3 68 15 82 300 8.4 0 8.5 8.5 11/18/2005 07:20:00 13.9 3.2 21.4 5.7 14.2 3.3 21.4 6.5 12.3 2.9 19.5 4.9 73 13 82 300 8.5 0 8.8 8.5 11/18/2005 07:30:00 13.3 3.6 21.8 4.9 13.4 3.6 21.8 5.7 11.4 3.2 18.7 4.6 70 16 90 300 8.4 0 8.5 8.3 11/18/2005 07:40:00 11.2 3.2 20.6 4.2 11.3 3.2 21 4.2 9.5 2.8 17.6 3.4 64 18 80 300 8.3 0 8.5 8.3 11/18/2005 07:50:00 10.1 3.1 21.8 3 10.2 3.2 21.8 2.6 7.9 2.8 18.3 3 63 22 47 300 8.1 0 8.3 8 11/18/2005 08:00:00 10.4 2.7 17.6 4.2 10.5 2.7 17.9 4.6 8.8 2.6 15.6 3.8 62 19 47 300 8.1 0 8.3 8 11/18/2005 08:10:00 11.2 2.5 17.6 4.9 11.3 2.6 17.6 3.8 9.3 2.6 15.6 3.8 66 16 52 300 8.4 0 8.8 8.3 11/18/2005 08:20:00 11.5 2.7 17.9 4.6 11.6 2.8 18.7 4.6 9.9 2.6 18.3 3.4 71 16 89 300 8.7 0 9 8.5 11/18/2005 08:30:00 12.6 3.2 22.6 5.3 12.7 3.2 22.1 5.3 11.2 3.1 20.2 4.2 75 16 85 300 8.8 0 9 8.5 11/18/2005 08:40:00 11.8 2.6 18.3 5.7 11.9 2.6 18.7 5.7 10.4 2.6 17.6 4.2 79 15 80 300 8.6 0 8.8 8.5 11/18/2005 08:50:00 13.3 3.2 20.2 5.7 13.5 3.2 21 6.5 11.9 3.1 20.2 4.2 75 15 77 300 8.4 0 8.8 8.3 11/18/2005 09:00:00 13.6 2.9 22.1 5.7 13.7 3.1 22.6 6.1 11.8 3.1 20.2 4.9 74 16 51 300 8 0 8.3 7.8 11/18/2005 09:10:00 12.8 2.9 20.2 4.6 12.9 2.9 20.6 5.7 11.2 2.8 18.3 5.7 73 17 72 300 8 0 8.3 7.8 11/18/2005 09:20:00 12 2.7 21 4.9 12.1 2.6 21 5.3 10.5 2.7 18.3 3.4 77 17 99 300 7.8 0 8 7.5 11/18/2005 09:30:00 11.7 3.3 20.2 3.8 11.9 3.3 20.6 4.6 10.4 3.5 19.9 2.6 70 16 87 300 7.5 0 7.8 7.3 11/18/2005 09:40:00 12.3 2.9 20.2 5.7 12.4 3.1 19.9 4.6 10.9 2.8 18.3 4.9 75 17 59 300 7.1 0 7.5 7 11/18/2005 09:50:00 11.7 2.9 18.3 4.6 11.8 2.9 18.7 4.6 9.7 2.5 16.8 3.4 68 17 61 300 6.8 0 7 6.7 11/18/2005 10:00:00 11.8 3.5 20.6 3.4 11.8 3.5 21 3.8 9.8 3.2 17.2 3 62 19 87 300 6.4 0.1 6.7 6.2 11/18/2005 10:10:00 12.2 3.5 21.8 4.9 12.2 3.8 22.6 4.6 9.7 3.3 18.3 3 60 18 57 300 6.1 0 6.2 5.7 11/18/2005 10:20:00 11.3 2.9 21 3.8 11.4 2.9 21.4 4.6 9.2 2.8 18.3 3.8 60 20 57 300 5.9 0 6 5.7 11/18/2005 10:30:00 12 2.7 19.5 5.3 12.2 2.8 19.1 5.3 10.4 2.5 19.9 5.3 63 16 69 300 5.9 0 6 5.7 11/18/2005 10:40:00 12.4 3.1 23.3 4.9 12.4 3.2 22.9 4.9 9.8 3.1 21 3.4 58 17 64 300 5.9 0 6 5.7 11/18/2005 10:50:00 10.9 2.5 18.3 4.9 10.9 2.6 18.7 4.6 8.4 2.6 17.6 2.6 55 17 53 300 5.9 0 6 5.7 11/18/2005 11:00:00 10.1 2.7 17.2 4.2 10.1 2.8 17.6 4.2 8 2.5 15.6 3 55 17 76 300 6.1 0 6.2 6 11/18/2005 11:10:00 8.7 2.3 15.3 3.8 8.6 2.3 14.9 3.4 7.2 2 12.6 3 57 18 52 300 5.9 0.1 6 5.7 11/18/2005 11:20:00 9.6 3.1 17.9 2.3 9.6 3.2 18.3 1.9 8 2.8 15.3 2.6 66 20 57 300 6 0 6.2 5.7 11/18/2005 11:30:00 9.4 2.5 15.6 3.8 9.5 2.6 16.4 4.2 8.1 2.5 15.3 3.4 66 17 73 300 6.1 0 6.2 6 11/18/2005 11:40:00 9.2 2.2 16.1 4.6 9.3 2.2 16.4 3.8 7.6 2.3 14.5 2.6 55 16 59 300 5.9 0.1 6 5.7 11/18/2005 11:50:00 9.3 2.1 14.5 4.6 9.3 2.3 14.9 3.8 7.6 2 13 3 62 18 71 300 5.7 0 5.7 5.7 11/18/2005 12:00:00 7.7 1.7 13.3 3.8 7.8 1.7 13.3 3.8 6.7 1.6 11.5 2.6 69 16 82 300 5.6 0 5.7 5.5 11/18/2005 12:10:00 9.5 2.1 15.6 4.6 9.6 2.1 15.6 5.3 8.3 1.9 13.7 3.4 72 15 77 300 5.6 0 5.7 5.5 11/18/2005 12:20:00 10.7 2.1 16.1 3.4 10.9 2.1 16.4 3.4 9.6 2 14.1 3.4 79 11 80 300 5.7 0 6 5.7 11/18/2005 12:30:00 11.7 1.9 16.1 6.8 11.9 2 16.4 6.8 10.3 1.8 14.5 4.6 78 11 83 300 5.9 0 6 5.7 11/18/2005 12:40:00 12.3 2.2 17.2 6.8 12.5 2.3 17.6 6.5 10.8 2.2 17.6 5.3 74 13 57 300 6.1 0 6.2 6 11/18/2005 12:50:00 12.2 2.6 17.6 5.3 12.4 2.6 17.9 6.1 10.5 2.5 17.2 5.3 71 13 75 300 6.1 0 6.2 6 11/18/2005 13:00:00 9.1 2.1 14.5 4.6 9.3 2.2 15.3 4.2 8.1 2.1 13.3 3.4 69 15 70 300 5.7 0 6 5.5 11/18/2005 13:10:00 8.4 2.1 13.3 3.4 8.5 2.2 13.7 3.4 7.2 1.8 12.2 2.3 69 18 68 300 5.6 0 5.7 5.5 11/18/2005 13:20:00 10.3 2.4 15.6 4.6 10.5 2.4 15.6 5.3 8.9 2.3 15.3 3.8 72 16 77 300 5.9 0 6 5.7 11/18/2005 13:30:00 11.8 2.3 19.1 6.1 11.9 2.4 19.1 6.1 10.1 2.3 17.9 5.3 72 15 72 300 6 0 6 6 11/18/2005 13:40:00 9.4 2.9 16.4 3.4 9.5 3.1 17.2 3 8 2.9 15.3 3 66 19 61 300 5.8 0.1 6 5.7 11/18/2005 13:50:00 9.1 2 15.3 4.2 9.2 2 15.3 4.2 7.5 2.1 12.6 3 66 15 72 300 5.7 0 6 5.7 11/18/2005 14:00:00 9.8 3.5 17.2 3.4 9.9 3.5 17.6 3.4 8.6 3.2 16.1 2.6 70 17 85 300 5.7 0 5.7 5.5 11/18/2005 14:10:00 10.2 2.5 17.2 5.3 10.3 2.6 17.6 5.3 8.9 2.5 16.8 4.2 73 13 75 300 5.6 0 5.7 5.5 11/18/2005 14:20:00 10.4 2.8 17.6 3.4 10.6 2.9 17.6 3.8 9 2.9 16.8 1.5 69 16 77 300 5.6 0 5.7 5.5 11/18/2005 14:30:00 10.1 2.5 16.4 4.2 10.1 2.6 16.8 3.8 8.5 2.5 16.4 3 63 15 80 300 5.4 0 5.7 5.5 11/18/2005 14:40:00 9.2 2.6 15.6 3.4 9.3 2.7 16.4 3.8 7.7 2.3 14.1 3 62 18 64 300 5.3 0 5.5 5.2 11/18/2005 14:50:00 9.9 2.7 16.1 3.4 10 2.8 16.1 2.6 8.6 2.6 16.1 3 61 17 79 300 5.2 0 5.5 5 11/18/2005 15:00:00 9.4 2.3 14.5 3.4 9.5 2.4 15.6 3.4 8.2 2.5 14.1 2.6 61 17 76 300 5.3 0 5.5 5.2 11/18/2005 15:10:00 8.7 2 14.5 3.4 8.8 2.1 14.5 2.6 6.8 2 11.5 2.6 52 20 35 300 5.2 0 5.5 5 11/18/2005 15:20:00 8.4 2 13.7 3 8.3 2.3 14.1 3 6.4 2.1 13 2.3 51 18 54 300 4.9 0 5 4.8 11/18/2005 15:30:00 9.5 2.4 15.3 3.8 9.5 2.5 16.1 3.8 7.9 2.4 15.3 2.6 60 17 59 300 4.9 0.1 5.2 4.8 11/18/2005 15:40:00 9.4 2.4 16.1 2.6 9.6 2.4 16.8 2.6 7.9 2.2 15.6 3.4 64 15 66 300 5.4 0 5.7 5.2 11/18/2005 15:50:00 10.8 2.3 16.1 4.2 11 2.3 16.8 5.7 9.4 2.2 16.1 4.2 72 13 72 300 5.4 0 5.5 5.5 11/18/2005 16:00:00 10.1 2 14.9 5.3 10.3 2.1 15.6 5.3 8.6 2.1 14.9 3.8 70 13 77 300 5.1 0.1 5.5 4.8 11/18/2005 16:10:00 8.8 1.9 14.1 3 9 1.9 14.5 3.4 7.5 1.8 13 3.4 66 15 73 300 4.6 0 4.8 4.5 11/18/2005 16:20:00 7.9 1.6 11.8 3 7.9 1.7 11.8 3.4 6.4 1.7 11.1 2.6 68 15 61 300 4.5 0 4.8 4.5 11/18/2005 16:30:00 7.7 1.6 12.2 3 7.8 1.7 12.2 3 6.2 1.7 10.7 2.3 62 15 79 300 4.6 0 4.8 4.5 11/18/2005 16:40:00 8 1.6 11.5 4.2 8.1 1.7 11.8 3.8 6.5 1.7 11.8 3 64 15 57 300 4.6 0 4.8 4.5 11/18/2005 16:50:00 6.7 1.6 10.7 2.6 6.7 1.7 11.1 1.5 5.7 1.5 9.9 2.6 65 15 83 300 4.8 0 5 4.8 11/18/2005 17:00:00 6.2 1.3 9.1 1.5 6.2 1.4 9.5 1.1 5.1 1.4 8.8 1.1 57 14 52 300 4.7 0 4.8 4.5 11/18/2005 17:10:00 6 1.3 9.1 2.3 6 1.4 9.1 2.3 4.7 1.1 8 1.1 48 14 31 300 4.5 0 4.5 4.5 11/18/2005 17:20:00 6.2 1 8.4 1.9 6.2 1 8.8 2.3 4.7 1.3 7.6 1.5 46 11 53 300 4.4 0 4.5 4.3 11/18/2005 17:30:00 6.7 1.1 9.1 3.4 6.7 1.1 8.8 3 5 1.2 8.8 1.9 47 9 59 300 4.4 0 4.5 4.3 11/18/2005 17:40:00 6.5 1.1 9.9 3.4 6.6 1.1 9.9 3.8 4.9 1.3 8.4 1.1 59 11 64 300 4.4 0 4.5 4.3 11/18/2005 17:50:00 6.1 1.3 9.5 2.6 6.2 1.3 9.5 2.6 4.8 1.3 8.8 1.9 59 12 66 300 4.8 0 5 4.5 11/18/2005 18:00:00 6.1 0.9 8.4 3.4 6.2 1 8.8 2.6 4.7 1.2 7.6 2.3 57 12 63 300 4.7 0.1 5 4.5 11/18/2005 18:10:00 6.4 1 9.5 3.4 6.4 1 9.1 3 4.5 1.2 7.6 1.9 50 11 65 300 4.6 0 4.8 4.5 11/18/2005 18:20:00 6.5 1 9.5 3.8 6.6 1.1 9.5 3.4 4.6 1.2 7.6 1.5 49 13 50 300 4.5 0 4.5 4.5 11/18/2005 18:30:00 7.2 1.1 9.5 4.2 7.3 1.2 9.9 3.4 5.4 1.5 9.9 1.9 50 12 51 300 4.6 0 4.8 4.5 11/18/2005 18:40:00 6.8 1.2 9.9 3.4 6.7 1.3 9.9 3 5.2 1.2 7.6 2.3 45 11 43 300 4.9 0.1 5 4.8 11/18/2005 18:50:00 6.5 1.4 9.1 3.4 6.5 1.5 9.5 3.4 5 1.3 9.1 1.9 54 13 49 300 5.1 0 5.2 5 11/18/2005 19:00:00 6.4 1.4 9.9 2.6 6.4 1.5 9.9 1.9 4.9 1.6 9.1 1.9 56 15 62 300 5.2 0 5.5 5 11/18/2005 19:10:00 6.8 1.4 10.3 3.4 6.7 1.5 10.3 3.4 5.2 1.3 8.8 2.6 45 13 40 300 5.3 0 5.7 5.2 11/18/2005 19:20:00 7.4 1.4 11.1 3.4 7.2 1.5 11.1 3 5.7 1.5 10.7 2.3 41 13 32 300 5.9 0 6 5.5 11/18/2005 19:30:00 7.3 1.6 11.8 3 7.2 1.7 12.2 3 5.5 1.7 9.5 1.9 49 17 46 300 6.1 0 6.2 6 11/18/2005 19:40:00 7.6 1.7 11.8 3 7.6 1.8 11.8 2.6 5.7 1.9 10.3 1.9 55 18 82 300 6.1 0 6.2 6 11/18/2005 19:50:00 7.7 1.7 12.2 3.4 7.6 1.9 13 3 5.9 1.9 11.5 1.9 51 16 45 300 6.2 0 6.5 6 11/18/2005 20:00:00 7.8 1.8 13.3 3.4 7.8 1.9 13 2.6 5.9 1.8 11.1 2.6 52 16 65 300 6.2 0 6.5 6.2 11/18/2005 20:10:00 8.4 1.5 12.6 4.6 8.3 1.7 12.6 3.8 6.4 1.9 11.8 2.3 51 13 45 300 6.2 0 6.2 6.2 11/18/2005 20:20:00 8.2 1.3 11.5 4.2 8.1 1.3 11.5 3.8 5.9 1.7 9.9 1.5 49 12 49 300 6.2 0 6.2 6.2 11/18/2005 20:30:00 7.3 1.3 11.1 3.4 7.3 1.5 11.5 3 5.4 1.7 10.7 2.3 50 13 52 300 6.2 0 6.5 6.2 11/18/2005 20:40:00 7.7 1.3 11.8 4.2 7.7 1.5 11.8 3.4 5.6 1.6 10.7 2.3 50 12 45 300 6.2 0 6.5 6.2 11/18/2005 20:50:00 6.9 1.5 10.3 3 6.9 1.5 10.3 2.6 5.2 1.5 9.1 1.5 53 14 47 300 6.2 0 6.5 6.2 11/18/2005 21:00:00 6.2 1.2 9.1 2.6 6.2 1.2 9.1 2.6 4.7 1.2 7.6 1.5 59 15 66 300 6.2 0 6.2 6.2 11/18/2005 21:10:00 6.5 1.2 9.5 3 6.5 1.3 9.5 3 4.8 1.3 8.8 2.3 53 13 64 300 6.2 0 6.2 6.2 11/18/2005 21:20:00 7 1.5 10.7 3 7 1.5 10.7 3.4 5.3 1.6 9.1 1.9 54 13 54 300 6.1 0 6.2 6 11/18/2005 21:30:00 7.6 1.4 11.8 3.8 7.5 1.4 11.5 4.2 5.4 1.8 10.3 1.1 50 12 49 300 6.1 0 6.2 6 11/18/2005 21:40:00 7 1.6 11.1 2.6 6.9 1.7 11.8 2.6 5.4 1.7 10.3 1.9 56 15 63 300 6.1 0 6.2 6 11/18/2005 21:50:00 7.4 1.7 10.7 3 7.3 1.7 11.1 2.6 5.8 1.5 10.3 2.6 58 15 59 300 6.1 0 6.2 6 11/18/2005 22:00:00 6.9 1.3 10.3 3 6.9 1.3 10.7 3 5.5 1.5 11.5 2.3 54 12 49 300 6.2 0 6.2 6.2 11/18/2005 22:10:00 6.5 1.2 9.5 3.4 6.5 1.3 9.9 3 4.9 1.5 9.5 1.9 52 13 48 300 6.3 0 6.5 6.2 11/18/2005 22:20:00 6.8 1.5 11.1 3 6.9 1.5 11.1 3.4 5.4 1.6 9.9 2.3 57 12 49 300 6.4 0 6.7 6.2 11/18/2005 22:30:00 6.6 1.3 9.5 3.8 6.6 1.3 9.9 3.4 5.1 1.4 9.1 2.3 57 12 56 300 6.5 0 6.7 6.5 11/18/2005 22:40:00 6.4 1.1 9.9 3 6.5 1.2 9.9 3 5.1 1.3 8 2.3 57 11 67 300 6.6 0 6.7 6.5 11/18/2005 22:50:00 6.5 1.4 10.3 1.9 6.4 1.5 10.3 2.3 5.2 1.4 9.1 1.9 53 15 70 300 6.6 0 6.7 6.5 11/18/2005 23:00:00 7.9 1.6 12.2 3.8 7.9 1.6 12.6 4.2 6.1 1.7 11.1 2.6 56 12 57 300 6.6 0 6.7 6.5 11/18/2005 23:10:00 7.9 1.7 12.6 3.8 7.9 1.8 12.6 3.4 6.2 1.9 11.5 1.9 59 17 53 300 6.6 0 6.7 6.5 11/18/2005 23:20:00 7.5 1.6 11.8 3.4 7.5 1.7 12.6 3 5.6 1.6 10.3 2.6 56 15 75 300 6.6 0 6.7 6.5 11/18/2005 23:30:00 8.4 1.6 12.6 4.6 8.4 1.7 13 4.2 6.4 1.9 11.8 1.9 55 13 52 300 6.5 0 6.7 6.5 11/18/2005 23:40:00 9.6 2.1 15.3 3.8 9.7 2.2 14.9 3.4 7.5 2.2 13 2.6 60 16 54 300 6.6 0 6.7 6.5 11/18/2005 23:50:00 8.5 1.7 14.5 2.6 8.5 1.8 14.9 3.4 6.9 1.7 14.1 2.6 62 17 65 300 6.7 0 6.7 6.7 11/19/2005 00:00:00 9.2 1.9 14.5 4.2 9.2 1.9 14.1 4.2 7.9 1.9 12.2 3 70 15 74 300 6.9 0 7 6.7 11/19/2005 00:10:00 10.3 1.8 15.3 4.6 10.5 1.8 15.3 4.6 9 1.8 13.3 4.9 71 13 68 300 7.1 0 7.3 7 11/19/2005 00:20:00 10.7 2.7 17.9 4.6 10.9 2.7 17.6 4.6 9.7 2.7 17.6 4.2 81 15 82 300 7.3 0.1 7.5 7.3 11/19/2005 00:30:00 10.9 2.5 18.3 5.3 11 2.5 17.6 5.7 9.7 2.4 17.9 4.6 78 16 105 300 7.8 0 7.8 7.5 11/19/2005 00:40:00 9.5 2.4 16.4 4.6 9.5 2.5 16.8 4.2 8.6 2.4 14.9 3.4 89 15 78 300 8 0 8.3 7.8 11/19/2005 00:50:00 8.3 2.1 16.1 3.8 8.5 2 15.3 4.2 7.5 2.1 15.6 3.4 139 43 111 300 7.8 0.1 8 7.3 11/19/2005 01:00:00 7.2 1.7 10.7 3.4 7.3 1.7 11.5 3.4 6.2 1.5 11.5 3 235 18 222 300 6.1 0.6 7.3 5.5 11/19/2005 01:10:00 6.4 1.4 9.9 2.6 6.4 1.3 9.9 2.6 5.5 1.5 9.1 1.5 257 14 263 300 5.2 0.1 5.5 5 11/19/2005 01:20:00 4.6 1.3 7.2 1.5 4.6 1.3 7.6 1.5 4.2 1.2 7.2 1.5 273 14 274 300 5.2 0 5.5 5 11/19/2005 01:30:00 3.1 1.1 6.1 1.1 3.1 1.1 6.1 1.1 2.8 0.8 4.9 1.1 290 22 279 300 5.2 0 5.5 5 11/19/2005 01:40:00 2.5 0.9 4.9 0.4 2.4 1 4.9 0.4 2.3 0.9 4.9 0.4 291 28 239 300 5.4 0 5.7 5.5 11/19/2005 01:50:00 2.6 0.8 4.6 0.7 2.4 1 4.6 0.4 2.6 0.9 4.9 0.7 280 15 276 300 5.5 0 5.7 5.5 11/19/2005 02:00:00 3.1 1 6.1 0.4 3 1 5.7 0.4 2.9 0.8 5.3 0.7 253 33 251 300 5.4 0 5.5 5.2 11/19/2005 02:10:00 3.2 0.7 4.9 1.5 3.1 0.8 5.3 1.5 3 0.7 4.9 1.5 281 17 289 300 5.2 0 5.5 5 11/19/2005 02:20:00 2 1.3 6.5 0.4 1.9 1.3 6.5 0.4 2.1 1.2 5.7 0.4 265 43 254 300 5.1 0 5.2 5 11/19/2005 02:30:00 5.8 1.5 9.9 1.9 5.8 1.5 9.5 1.5 5 1.3 8 1.5 271 24 228 300 4.8 0 5 4.8 11/19/2005 02:40:00 7.6 2.3 13.7 3.4 7.6 2.2 13.3 3.8 6.6 2 12.6 3 256 17 248 300 4.8 0 5 4.5 11/19/2005 02:50:00 8.1 2.1 13 3 8.1 2.2 13.3 3 7.5 2 12.2 2.6 253 15 219 300 4.9 0 5 4.8 11/19/2005 03:00:00 7.8 2.2 13.3 1.9 7.8 2.1 13.3 2.3 7 2 13 2.6 237 14 216 300 4.5 0 4.8 4.3 11/19/2005 03:10:00 6.5 1.7 11.8 3 6.5 1.6 11.8 3 5.8 1.7 9.9 1.5 238 17 259 300 4.2 0 4.5 4 11/19/2005 03:20:00 6 1.5 11.5 3.4 6 1.5 11.1 3.8 5.2 1.5 10.7 2.3 247 17 255 300 4 0 4.3 4 11/19/2005 03:30:00 6 1.3 10.7 2.6 5.9 1.3 10.3 1.9 5.3 1.2 9.9 3 256 13 260 300 4 0 4 3.8 11/19/2005 03:40:00 6.1 1.3 9.1 3 6.1 1.2 8.8 2.6 5.6 1.5 8.8 2.3 254 15 256 300 4 0 4.3 3.8 11/19/2005 03:50:00 6.8 2.3 13.3 1.9 6.9 2.2 13 2.6 6.2 2 10.7 2.3 238 18 219 300 4 0 4.3 3.8 11/19/2005 04:00:00 7.3 2.2 13.3 2.6 7.3 2.2 13.3 3 6.3 1.9 13 2.6 240 15 250 300 3.6 0.1 4 3.5 11/19/2005 04:10:00 6.1 2 10.7 1.5 6.1 1.9 10.3 1.5 5.4 1.9 10.3 0.7 240 15 226 300 3.3 0 3.5 3.3 11/19/2005 04:20:00 5.7 1.5 9.5 2.3 5.8 1.5 9.5 1.9 4.9 1.5 9.1 1.5 242 18 264 300 3.2 0 3.5 3.3 11/19/2005 04:30:00 6.1 1.8 11.1 2.6 6.2 1.7 11.1 2.3 5.4 1.8 9.9 1.5 239 16 220 300 3.1 0 3.3 3 11/19/2005 04:40:00 6.3 1.9 11.1 2.6 6.3 1.8 10.3 2.3 5.6 1.8 9.9 2.3 242 16 209 300 3 0 3.3 2.8 11/19/2005 04:50:00 6.4 2.1 11.1 1.9 6.4 2 11.8 2.3 5.7 1.7 9.9 1.9 249 15 252 300 2.8 0 2.8 2.6 11/19/2005 05:00:00 5 1.4 8.4 1.9 5.1 1.4 8.8 1.5 4.4 1.4 8.4 1.1 244 16 213 300 2.5 0.1 2.8 2.3 11/19/2005 05:10:00 5.3 1.3 8.8 2.3 5.3 1.3 9.1 2.3 4.8 1.2 8.8 2.6 251 17 239 300 2.3 0 2.3 2.3 11/19/2005 05:20:00 4.1 1.6 8 0.4 4.1 1.6 7.6 0.4 3.5 1.4 6.8 0.4 263 17 233 300 2.3 0 2.3 2.1 11/19/2005 05:30:00 5 0.9 7.2 3.4 5.1 0.9 7.2 3 4.7 0.8 6.8 3 273 12 264 300 2.2 0 2.3 2.1 11/19/2005 05:40:00 2.9 0.8 6.1 1.1 3 0.8 5.7 1.1 2.6 0.6 4.9 1.5 294 15 268 300 2.1 0 2.3 2.1 11/19/2005 05:50:00 2.6 0.8 4.6 0.4 2.6 0.8 4.6 0.4 2.4 0.6 3.8 1.1 304 10 325 300 2 0 2.3 2.1 11/19/2005 06:00:00 3.4 0.9 5.7 1.9 3.4 0.9 6.1 1.1 3.1 0.7 5.7 1.5 297 10 296 300 2.1 0 2.3 2.1 11/19/2005 06:10:00 3.9 0.9 6.8 1.5 4.1 1 6.8 1.9 3.6 1 6.1 1.1 284 10 268 300 2.1 0 2.3 2.1 11/19/2005 06:20:00 3.2 0.5 4.2 1.5 3.3 0.5 4.6 1.9 2.8 0.5 3.8 1.5 297 12 301 300 2.1 0 2.3 2.1 11/19/2005 06:30:00 3.8 0.8 6.1 1.9 3.9 0.8 6.1 1.9 3.5 0.9 5.7 1.5 298 17 300 300 2.1 0 2.3 2.1 11/19/2005 06:40:00 3.2 0.7 5.3 1.5 3.2 0.7 5.3 1.5 2.9 0.7 4.6 1.1 300 13 278 300 2.1 0 2.3 2.1 11/19/2005 06:50:00 3.3 0.6 4.9 1.9 3.3 0.6 5.3 1.9 2.9 0.6 4.6 1.9 297 11 295 300 2.1 0 2.3 2.1 11/19/2005 07:00:00 2.5 0.6 4.6 1.1 2.5 0.6 4.6 0.7 2.4 0.6 3.8 1.1 295 11 280 300 2.1 0 2.3 2.1 11/19/2005 07:10:00 1.8 0.5 3 0.7 1.7 0.5 2.6 0.4 1.7 0.5 2.6 0.7 331 22 299 300 2.1 0 2.3 2.1 11/19/2005 07:20:00 1.9 0.6 3 0.4 1.8 0.6 3 0.4 1.9 0.6 3 0.7 339 9 334 300 2.1 0 2.3 2.1 11/19/2005 07:30:00 1.9 0.6 3.4 0.7 1.8 0.7 3.4 0.4 2.1 0.5 3 1.1 331 13 317 300 2.1 0 2.3 2.1 11/19/2005 07:40:00 1.6 0.3 2.3 0.7 1.5 0.3 2.3 0.7 1.6 0.3 2.3 0.7 349 7 350 300 2.1 0 2.3 1.8 11/19/2005 07:50:00 1.2 0.6 2.3 0.4 1.1 0.6 2.3 0.4 1.3 0.5 2.3 0.4 344 6 338 300 2 0 2.3 1.8 11/19/2005 08:00:00 1.9 0.4 3 0.7 1.7 0.4 3 0.7 1.7 0.5 2.6 0.4 355 11 326 300 2 0 2.1 1.8 11/19/2005 08:10:00 1.1 0.7 2.3 0.4 1 0.6 2.3 0.4 1.2 0.7 2.6 0.4 329 24 312 300 2.1 0 2.3 2.1 11/19/2005 08:20:00 2.5 0.5 4.2 0.7 2.4 0.6 4.2 0.7 2.6 0.5 3.8 1.1 301 9 286 300 2.1 0 2.3 2.1 11/19/2005 08:30:00 0.7 0.4 2.3 0.4 0.5 0.3 1.9 0.4 0.8 0.4 1.9 0.4 338 32 331 300 2.1 0 2.3 2.1 11/19/2005 08:40:00 1.2 0.6 2.6 0.4 1.1 0.6 2.3 0.4 1.3 0.6 2.6 0.4 336 11 334 300 2.1 0 2.3 2.1 11/19/2005 08:50:00 1.3 0.5 2.3 0.4 1.1 0.5 2.3 0.4 1.2 0.4 2.3 0.4 320 11 337 300 2.1 0 2.3 2.1 11/19/2005 09:00:00 0.5 0.3 1.5 0.4 0.4 0.2 1.5 0.4 0.5 0.2 1.5 0.4 326 22 319 300 2 0 2.3 2.1 11/19/2005 09:10:00 1.3 0.7 2.3 0.4 1.2 0.7 2.3 0.4 1.3 0.6 2.3 0.4 311 8 319 300 2.1 0 2.3 2.1 11/19/2005 09:20:00 1.1 0.6 2.3 0.4 0.9 0.7 2.3 0.4 1.3 0.7 2.3 0.4 285 12 273 300 2.1 0 2.3 2.1 11/19/2005 09:30:00 1.4 0.3 2.3 0.7 1.2 0.4 1.9 0.4 1.2 0.5 2.3 0.4 251 6 272 300 2.1 0 2.3 2.1 11/19/2005 09:40:00 1.9 0.5 3 1.1 1.9 0.5 2.6 0.7 1.8 0.4 2.6 0.7 271 8 270 300 2.1 0 2.3 2.1 11/19/2005 09:50:00 2.7 0.5 3.8 1.5 2.7 0.5 4.2 1.5 2.4 0.5 3.8 1.5 279 7 268 300 2.1 0 2.3 2.1 11/19/2005 10:00:00 3.6 0.6 4.9 2.3 3.6 0.6 4.9 2.3 3.3 0.6 4.9 1.9 283 8 277 300 2.1 0 2.3 2.1 11/19/2005 10:10:00 3.6 0.7 4.9 1.9 3.7 0.7 5.3 1.9 3.5 0.6 4.9 2.3 287 7 288 300 2.1 0 2.3 2.1 11/19/2005 10:20:00 2.4 0.8 4.2 0.4 2.4 0.9 4.2 0.4 2.2 0.7 4.2 0.7 303 12 285 300 2.1 0 2.3 2.1 11/19/2005 10:30:00 2.6 0.8 4.6 1.1 2.6 0.8 4.2 1.1 2.4 0.7 3.8 0.7 298 11 306 300 2.1 0 2.3 2.1 11/19/2005 10:40:00 3.6 0.6 5.3 2.3 3.6 0.6 4.9 1.9 3.3 0.6 5.3 1.9 287 8 299 300 2.1 0 2.3 2.1 11/19/2005 10:50:00 3.5 0.6 4.9 1.9 3.5 0.6 4.6 1.9 3.2 0.5 4.6 1.9 280 9 282 300 2.2 0 2.3 2.1 11/19/2005 11:00:00 2.9 0.7 4.9 1.5 2.9 0.7 4.9 1.5 2.9 0.6 4.9 1.5 276 11 261 300 2.1 0 2.3 2.1 11/19/2005 11:10:00 3.2 0.6 5.3 1.5 3.2 0.7 5.3 1.9 3.1 0.7 5.3 1.9 281 11 299 300 2.1 0 2.3 1.8 11/19/2005 11:20:00 3.5 0.6 5.3 1.9 3.5 0.5 5.3 2.3 3.4 0.7 5.7 1.9 271 11 274 300 2 0 2.1 1.8 11/19/2005 11:30:00 3.7 0.6 5.3 2.3 3.7 0.6 5.7 2.3 3.5 0.6 4.9 1.9 277 10 270 300 1.9 0 2.1 1.8 11/19/2005 11:40:00 3.4 0.7 5.3 1.9 3.4 0.6 4.9 1.9 3.2 0.7 4.9 1.9 276 9 280 300 1.9 0 2.1 1.8 11/19/2005 11:50:00 3.1 0.5 4.9 1.9 3.1 0.5 4.9 1.9 3 0.5 4.2 1.9 274 9 279 300 1.9 0 2.1 1.8 11/19/2005 12:00:00 3.5 0.5 4.6 2.6 3.5 0.5 4.9 2.3 3.5 0.4 4.6 2.3 270 8 275 300 1.8 0 2.1 1.8 11/19/2005 12:10:00 3.3 0.6 4.9 1.9 3.2 0.6 4.9 1.9 3.3 0.5 4.9 2.3 262 10 276 300 1.9 0 2.1 1.8 11/19/2005 12:20:00 3.7 0.7 5.3 1.9 3.7 0.7 5.3 1.9 3.7 0.7 5.3 1.9 262 11 270 300 1.9 0 2.1 1.8 11/19/2005 12:30:00 3.7 0.8 5.3 1.9 3.8 0.8 5.3 1.5 3.5 0.7 4.9 1.9 271 9 273 300 1.8 0 2.1 1.8 11/19/2005 12:40:00 3.5 0.7 4.9 1.5 3.4 0.6 4.9 1.5 3.4 0.6 4.9 1.9 267 10 279 300 1.8 0 1.8 1.8 11/19/2005 12:50:00 2.9 0.5 4.2 1.5 2.8 0.5 4.2 0.7 2.8 0.5 3.8 1.5 266 10 272 300 1.8 0 1.8 1.8 11/19/2005 13:00:00 3 0.4 4.2 1.9 2.9 0.4 4.2 1.5 2.9 0.5 4.2 1.9 276 12 294 300 1.8 0 1.8 1.8 11/19/2005 13:10:00 3.3 0.7 5.3 1.5 3.2 0.6 5.7 1.5 3.1 0.7 4.6 1.9 266 12 273 300 1.8 0 1.8 1.8 11/19/2005 13:20:00 3 0.6 4.6 1.5 2.9 0.6 4.6 1.1 2.8 0.7 4.6 0.7 259 12 261 300 1.8 0 1.8 1.8 11/19/2005 13:30:00 3.2 0.6 4.6 1.5 3 0.6 4.6 1.5 3 0.6 4.6 0.7 256 11 253 300 1.8 0 1.8 1.8 11/19/2005 13:40:00 1.8 0.6 3.8 0.4 1.7 0.6 3.4 0.4 1.8 0.6 3.8 0.7 255 13 256 300 1.8 0 1.8 1.8 11/19/2005 13:50:00 2.1 0.4 3 0.7 2 0.4 3 0.7 1.9 0.5 3 0.4 256 12 256 300 1.8 0 1.8 1.6 11/19/2005 14:00:00 1.9 1 3.4 0.4 1.8 0.9 3.4 0.4 1.8 0.9 3.4 0.4 233 15 233 300 1.7 0 1.8 1.6 11/19/2005 14:10:00 2 0.8 3.4 0.4 1.9 0.8 3.4 0.4 1.8 0.7 3.4 0.4 234 15 234 300 1.6 0 1.8 1.6 11/19/2005 14:20:00 2.8 0.8 4.2 0.4 2.7 0.7 4.2 0.4 2.6 0.7 4.6 1.1 232 13 235 300 1.4 0 1.6 1.4 11/19/2005 14:30:00 3.3 0.7 4.9 1.1 3.1 0.6 4.6 1.5 2.9 0.6 4.6 1.1 236 11 213 300 1.4 0 1.6 1.4 11/19/2005 14:40:00 2.8 0.9 5.3 0.4 2.7 0.8 4.9 0.4 2.5 0.7 4.6 0.7 237 12 235 300 1.3 0 1.4 1.4 11/19/2005 14:50:00 2.9 0.9 6.5 0.7 2.8 0.9 6.1 0.7 2.5 0.8 4.6 0.7 233 16 226 300 1.2 0 1.4 1.1 11/19/2005 15:00:00 4.2 1 6.5 1.9 4 1 6.1 1.9 3.7 1 6.5 1.9 237 12 233 300 1.1 0 1.4 0.9 11/19/2005 15:10:00 3.6 1 6.5 1.5 3.5 1 6.1 1.5 3.4 0.9 5.7 1.5 247 15 247 300 0.9 0 1.1 0.9 11/19/2005 15:20:00 3.9 0.8 6.1 1.9 3.8 0.8 5.3 1.9 3.4 0.9 5.7 1.1 249 12 226 300 0.7 0 0.9 0.7 11/19/2005 15:30:00 3.3 0.6 4.9 1.9 3.2 0.6 4.9 1.5 2.9 0.7 4.6 1.1 252 12 261 300 0.6 0 0.7 0.7 11/19/2005 15:40:00 2.7 0.5 4.6 1.1 2.6 0.5 4.2 0.4 2.4 0.5 4.2 1.1 251 11 252 300 0.5 0 0.7 0.4 11/19/2005 15:50:00 2 0.4 3 0.7 1.8 0.4 2.6 0.4 1.9 0.4 3 0.7 255 13 260 300 0.4 0 0.7 0.2 11/19/2005 16:00:00 1.8 0.5 3 0.7 1.6 0.5 3 0.4 1.7 0.5 3 0.7 265 10 268 300 0.2 0 0.4 0.2 11/19/2005 16:10:00 1.9 0.4 2.6 1.1 1.8 0.4 2.6 1.1 1.9 0.4 2.6 1.1 262 8 263 300 0.1 0 0.2 0.2 11/19/2005 16:20:00 1.3 0.6 2.3 0.4 1.1 0.5 2.3 0.4 1.2 0.5 2.3 0.4 261 9 273 300 0.1 0 0.2 0.2 11/19/2005 16:30:00 2.2 0.9 3.8 0.4 2 0.9 3.8 0.4 2.2 0.7 3.8 0.7 264 12 250 300 0.1 0 0.2 0.2 11/19/2005 16:40:00 2.5 0.4 3.4 1.1 2.3 0.4 3.4 0.7 2.3 0.4 3 1.1 255 9 265 300 0.2 0 0.2 0.2 11/19/2005 16:50:00 2.3 0.5 3.8 1.1 2.1 0.5 3.4 1.1 2.2 0.4 3.8 1.1 259 11 258 300 0.1 0 0.2 0.2 11/19/2005 17:00:00 2 0.6 3.8 0.7 1.8 0.6 3.4 0.7 2 0.6 3.8 0.7 256 15 258 300 0.1 0 0.2 0.2 11/19/2005 17:10:00 2.1 0.7 3.8 0.7 1.9 0.6 3.4 0.7 1.9 0.6 3 0.7 246 17 238 300 0.1 0 0.2 0.2 11/19/2005 17:20:00 2.8 0.5 4.2 1.5 2.7 0.5 4.2 1.5 2.6 0.6 4.2 1.1 255 14 240 300 0.1 0 0.2 0.2 11/19/2005 17:30:00 2 0.5 3.4 0.4 1.8 0.6 3.4 0.4 1.9 0.7 3.4 0.4 253 12 272 300 0.1 0 0.2 0.2 11/19/2005 17:40:00 2.4 0.8 4.6 0.4 2.3 0.8 4.6 0.4 2.2 0.6 4.2 1.1 247 13 216 300 0.1 0 0.2 0.2 11/19/2005 17:50:00 1.5 0.6 3 0.4 1.4 0.6 2.6 0.4 1.4 0.6 2.6 0.4 243 16 253 300 0.1 0 0.2 -0.1 11/19/2005 18:00:00 2.6 0.8 4.2 0.4 2.4 0.9 4.2 0.4 2.4 0.7 3.8 0.7 257 11 256 300 0 0 0.2 -0.1 11/19/2005 18:10:00 2.1 0.6 3.4 0.7 1.9 0.6 3.4 0.4 1.9 0.5 3 0.7 256 16 252 300 -0.1 0 0.2 -0.1 11/19/2005 18:20:00 1.5 0.6 3 0.7 1.3 0.6 3 0.4 1.4 0.5 3 0.4 252 17 235 300 -0.1 0 -0.1 -0.1 11/19/2005 18:30:00 1.6 0.9 3.4 0.4 1.4 0.9 3.4 0.4 1.5 0.9 3.8 0.4 259 19 234 300 -0.2 0 -0.1 -0.3 11/19/2005 18:40:00 2.3 0.5 3.8 1.1 2.1 0.5 3.8 1.1 2.1 0.6 3.4 0.7 261 13 251 300 -0.2 0 -0.1 -0.3 11/19/2005 18:50:00 2.8 0.9 4.6 0.4 2.7 1 4.6 0.4 2.7 0.9 4.9 0.7 285 20 286 300 -0.3 0 -0.1 -0.5 11/19/2005 19:00:00 2.2 0.7 4.9 1.1 2.1 0.7 4.9 0.7 2.2 0.6 3.8 0.7 261 15 271 300 -0.4 0 -0.3 -0.5 11/19/2005 19:10:00 2.3 0.9 5.3 0.4 2.1 1 5.3 0.4 2.2 0.8 5.3 0.4 278 27 277 300 -0.5 0 -0.5 -0.5 11/19/2005 19:20:00 1.1 0.6 2.6 0.4 1.1 0.6 2.3 0.4 1.2 0.5 2.6 0.4 302 16 288 300 -0.5 0 -0.5 -0.5 11/19/2005 19:30:00 1.1 0.8 3.4 0.4 1 0.8 3.4 0.4 1.1 0.8 3.4 0.4 301 19 310 300 -0.5 0 -0.5 -0.5 11/19/2005 19:40:00 2.1 0.8 4.6 0.4 1.9 0.9 4.2 0.4 2.1 0.8 4.6 0.7 254 23 263 300 -0.5 0 -0.5 -0.5 11/19/2005 19:50:00 2.8 1 4.9 0.7 2.7 1 4.9 0.7 2.5 1 5.3 0.7 258 16 282 300 -0.5 0 -0.5 -0.5 11/19/2005 20:00:00 2.4 0.9 4.6 0.7 2.4 0.9 4.2 0.7 2.3 0.8 4.2 0.7 281 14 267 300 -0.5 0 -0.5 -0.7 11/19/2005 20:10:00 2.1 0.7 3.4 0.4 2 0.7 3.4 0.4 2.1 0.6 3.4 0.7 294 18 300 300 -0.6 0 -0.5 -0.7 11/19/2005 20:20:00 2.2 0.6 3.8 0.4 2.1 0.7 3.8 0.4 2 0.5 3.4 0.7 326 22 351 300 -0.7 0 -0.5 -0.7 11/19/2005 20:30:00 2.5 0.5 3.8 1.1 2.4 0.5 3.4 1.1 2.1 0.6 3.8 0.7 357 13 12 300 -0.7 0 -0.5 -0.7 11/19/2005 20:40:00 2.6 0.5 3.8 1.1 2.5 0.6 3.8 0.7 2.2 0.5 3.4 0.7 359 10 356 300 -0.7 0 -0.5 -0.7 11/19/2005 20:50:00 2.7 0.6 3.8 1.1 2.6 0.7 3.8 0.7 2.5 0.8 4.2 0.7 355 11 354 300 -0.7 0 -0.5 -0.7 11/19/2005 21:00:00 2 1.1 4.2 0.4 1.9 1.1 4.2 0.4 1.9 1.1 3.8 0.4 331 18 338 300 -0.5 0 -0.5 -0.7 11/19/2005 21:10:00 0.8 0.6 2.3 0.4 0.8 0.5 2.3 0.4 1 0.6 2.3 0.4 336 30 4 300 -0.5 0 -0.3 -0.5 11/19/2005 21:20:00 0.8 0.5 2.6 0.4 0.7 0.5 2.3 0.4 0.7 0.5 1.9 0.4 270 38 226 300 -0.5 0 -0.5 -0.5 11/19/2005 21:30:00 0.4 0.2 1.5 0.4 0.4 0.1 1.5 0.4 0.4 0.1 1.1 0.4 288 38 2 300 -0.6 0 -0.5 -0.7 11/19/2005 21:40:00 1.5 0.7 3 0.4 1.3 0.7 2.6 0.4 1.4 0.6 3.4 0.4 328 19 334 300 -0.7 0 -0.5 -0.7 11/19/2005 21:50:00 1.2 1 3.4 0.4 1 0.9 3.8 0.4 1.1 0.8 3.4 0.4 299 23 259 300 -0.6 0 -0.5 -0.7 11/19/2005 22:00:00 2.2 0.8 3.8 0.7 2.1 0.8 3.8 0.4 2.1 0.7 3.8 0.7 264 24 265 300 -0.5 0 -0.5 -0.5 11/19/2005 22:10:00 1.2 1 4.2 0.4 1.1 1 3.8 0.4 1 0.8 3.8 0.4 231 17 222 300 -0.6 0 -0.5 -0.7 11/19/2005 22:20:00 4.2 1 6.8 1.9 4.1 1 6.5 1.5 3.8 0.9 6.1 1.5 252 17 253 300 -0.7 0 -0.5 -0.7 11/19/2005 22:30:00 3.3 0.9 5.7 1.5 3.2 0.9 5.7 1.1 2.9 0.9 5.3 1.1 249 17 253 300 -0.9 0 -0.7 -0.7 11/19/2005 22:40:00 3.7 0.8 5.7 1.9 3.6 0.8 5.7 1.9 3.4 0.8 5.7 1.9 263 17 257 300 -0.9 0 -0.7 -1 11/19/2005 22:50:00 2.9 0.6 4.2 1.5 2.8 0.6 4.2 1.5 2.7 0.6 4.2 1.1 270 17 263 300 -1 0 -1 -1.2 11/19/2005 23:00:00 2.3 0.6 3.8 1.1 2.2 0.6 3.8 0.7 2.2 0.6 3.8 0.4 285 24 289 300 -1 0 -1 -1.2 11/19/2005 23:10:00 2.1 0.8 4.2 0.4 2 0.8 4.2 0.4 1.8 1 5.3 0.4 301 18 277 300 -1.2 0 -1 -1.2 11/19/2005 23:20:00 2.6 0.9 4.6 0.4 2.4 1 4.6 0.4 2.5 0.8 4.6 0.7 311 17 291 300 -1.2 0 -1.2 -1.2 11/19/2005 23:30:00 2.1 0.5 3.4 1.1 2 0.5 3.4 0.7 1.9 0.5 3 0.7 324 17 320 300 -1.3 0 -1.2 -1.4 11/19/2005 23:40:00 1.8 1.1 5.7 0.4 1.7 1.1 5.7 0.4 1.8 0.9 4.6 0.4 313 17 299 300 -1.3 0 -1.2 -1.4 11/19/2005 23:50:00 2 1 5.3 0.4 1.9 1 4.9 0.4 1.8 0.9 4.2 0.4 279 28 224 300 -1.2 0 -1.2 -1.2 11/20/2005 00:00:00 1.7 0.7 3.4 0.4 1.6 0.7 3.8 0.4 1.5 0.7 3 0.4 258 24 253 300 -1.2 0 -0.7 -1.2 11/20/2005 00:10:00 3.3 1 5.7 1.5 3.2 1 5.3 1.5 3.1 1 5.7 1.1 260 17 247 300 -1.2 0 -1 -1.2 11/20/2005 00:20:00 2.2 0.6 3.4 0.7 2.1 0.6 3.4 0.7 2.1 0.6 3.4 0.7 306 13 324 300 -1.4 0.1 -1.2 -1.4 11/20/2005 00:30:00 2.8 0.6 4.2 1.1 2.7 0.7 4.2 0.7 2.6 0.7 4.2 1.1 310 17 285 300 -1.4 0 -1.2 -1.4 11/20/2005 00:40:00 2.7 0.7 4.2 1.5 2.7 0.8 4.2 1.1 2.5 0.6 3.8 1.5 308 11 336 300 -1.5 0 -1.4 -1.4 11/20/2005 00:50:00 2.5 0.5 3.8 1.1 2.4 0.5 3.8 1.1 2.3 0.5 3.8 1.1 321 17 309 300 -1.6 0 -1.4 -1.4 11/20/2005 01:00:00 2.7 0.6 4.2 1.1 2.6 0.6 4.6 1.1 2.5 0.7 4.6 1.1 312 15 300 300 -1.6 0 -1.4 -1.4 11/20/2005 01:10:00 3 0.7 4.6 1.5 2.9 0.7 4.6 1.1 2.6 0.6 4.2 1.1 316 13 324 300 -1.6 0 -1.4 -1.7 11/20/2005 01:20:00 3.6 0.4 4.9 2.6 3.5 0.5 4.9 2.6 3.3 0.5 4.6 2.3 319 12 328 300 -1.6 0 -1.4 -1.7 11/20/2005 01:30:00 2.8 0.8 4.9 1.1 2.8 0.8 4.9 0.7 2.5 0.8 4.9 0.4 323 12 323 300 -1.7 0 -1.4 -1.7 11/20/2005 01:40:00 2.8 0.6 4.6 1.1 2.7 0.6 4.6 1.1 2.4 0.5 3.4 0.7 312 14 300 300 -1.7 0 -1.4 -1.9 11/20/2005 01:50:00 2.4 0.4 3.4 1.5 2.3 0.4 3.4 1.1 2 0.5 3 0.4 337 10 335 300 -1.8 0 -1.4 -1.9 11/20/2005 02:00:00 1.8 0.5 3 0.4 1.7 0.6 3 0.4 1.5 0.6 3 0.4 318 13 341 300 -1.8 0 -1.7 -1.9 11/20/2005 02:10:00 1.8 0.5 2.6 0.4 1.6 0.5 2.6 0.4 1.5 0.4 2.6 0.4 340 12 318 300 -2 0 -1.9 -2.1 11/20/2005 02:20:00 1.6 0.5 2.6 0.4 1.3 0.6 2.6 0.4 1.3 0.5 2.6 0.4 2 17 347 300 -2.1 0 -1.9 -2.1 11/20/2005 02:30:00 1.7 0.4 2.6 0.7 1.4 0.4 2.3 0.4 1.5 0.3 2.3 0.7 23 12 39 300 -2.1 0 -1.9 -2.1 11/20/2005 02:40:00 1.8 0.4 2.6 0.7 1.5 0.5 2.6 0.4 1.4 0.4 2.6 0.7 14 12 9 300 -2.1 0 -2.1 -2.1 11/20/2005 02:50:00 1.3 0.5 2.3 0.4 1 0.5 2.3 0.4 1 0.5 2.3 0.4 22 12 36 300 -2.2 0 -2.1 -2.4 11/20/2005 03:00:00 1.1 0.4 1.9 0.4 0.8 0.4 1.9 0.4 0.9 0.4 1.9 0.4 15 15 32 300 -2.4 0 -2.1 -2.6 11/20/2005 03:10:00 1.6 0.5 2.6 0.7 1.4 0.5 2.6 0.4 1.2 0.4 2.3 0.4 345 13 344 300 -2.4 0 -2.4 -2.6 11/20/2005 03:20:00 1.7 1 3.8 0.4 1.7 1 3.8 0.4 1.5 0.9 3.4 0.4 288 17 291 300 -2.4 0 -2.1 -2.6 11/20/2005 03:30:00 2.5 0.5 4.2 1.1 2.4 0.6 4.2 0.7 2.2 0.6 3.8 1.1 267 17 237 300 -2.3 0 -2.1 -2.4 11/20/2005 03:40:00 2.8 0.6 3.8 0.7 2.6 0.7 3.8 0.4 2.7 0.6 4.2 1.1 261 10 245 300 -2.3 0 -2.1 -2.4 11/20/2005 03:50:00 2.2 0.7 4.9 0.7 2.1 0.7 4.6 0.7 1.9 0.8 4.6 0.4 268 11 254 300 -2.5 0 -2.1 -2.6 11/20/2005 04:00:00 1.6 0.4 2.6 0.7 1.4 0.4 2.3 0.4 1.4 0.4 2.6 0.4 270 16 256 300 -2.6 0 -2.6 -2.8 11/20/2005 04:10:00 1.2 0.3 1.9 0.4 1 0.4 1.9 0.4 1.2 0.2 1.5 0.7 316 13 328 300 -2.8 0 -2.6 -2.8 11/20/2005 04:20:00 1.7 0.3 2.3 1.1 1.5 0.3 2.3 0.7 1.4 0.4 2.3 0.4 353 9 354 300 -2.9 0 -2.8 -3 11/20/2005 04:30:00 2.1 0.4 3 1.1 1.9 0.4 2.6 0.7 1.4 0.4 2.6 0.7 6 8 1 300 -2.9 0 -2.8 -3 11/20/2005 04:40:00 1.9 0.5 2.6 0.7 1.6 0.5 2.6 0.4 1.2 0.4 2.3 0.4 13 9 18 300 -2.9 0 -2.8 -3 11/20/2005 04:50:00 1.6 0.6 2.6 0.4 1.4 0.7 2.6 0.4 1.1 0.5 2.3 0.4 11 9 13 300 -3 0 -2.8 -3 11/20/2005 05:00:00 1.7 0.4 2.6 0.4 1.4 0.4 2.3 0.4 1.1 0.4 1.9 0.4 24 10 21 300 -3.1 0 -2.8 -3.3 11/20/2005 05:10:00 1.8 0.4 2.6 0.7 1.5 0.4 2.6 0.4 1.3 0.4 2.3 0.4 35 9 34 300 -3.3 0 -3.3 -3.5 11/20/2005 05:20:00 2.4 0.3 3 1.5 2.3 0.4 3 1.1 1.7 0.4 2.6 0.7 40 5 46 300 -3.5 0 -3.3 -3.5 11/20/2005 05:30:00 2.7 0.3 3.4 1.9 2.5 0.3 3.4 1.5 1.7 0.4 3 0.7 40 6 40 300 -3.5 0 -3.3 -3.5 11/20/2005 05:40:00 2.8 0.4 3.8 1.5 2.7 0.5 3.8 1.5 1.8 0.4 3 0.7 39 6 41 300 -3.6 0 -3.5 -3.5 11/20/2005 05:50:00 1.9 0.4 3 0.7 1.8 0.4 2.6 0.7 1.2 0.4 2.3 0.4 50 8 45 300 -3.7 0 -3.5 -3.9 11/20/2005 06:00:00 2.2 0.4 3 0.7 2.1 0.4 3 0.4 1.6 0.4 2.6 0.4 46 9 47 300 -3.8 0 -3.7 -3.9 11/20/2005 06:10:00 2.4 0.4 3.4 1.1 2.2 0.4 3.4 1.1 1.6 0.4 2.6 0.7 41 7 39 300 -4.1 0.1 -3.7 -4.4 11/20/2005 06:20:00 2.8 0.3 3.4 1.9 2.7 0.4 3.4 1.5 1.9 0.4 3 0.7 38 6 41 300 -4.2 0 -3.9 -4.4 11/20/2005 06:30:00 3.1 0.4 4.6 1.9 2.8 0.5 4.2 1.9 1.9 0.5 3.4 0.7 39 7 40 300 -4.3 0 -3.9 -4.4 11/20/2005 06:40:00 3.3 0.5 4.6 2.3 3.2 0.5 4.2 1.5 2.2 0.5 3.4 1.1 39 6 45 300 -4.3 0 -4.4 -4.4 11/20/2005 06:50:00 3.2 0.5 4.2 1.9 3.1 0.5 4.2 1.9 2 0.7 3.4 0.4 46 8 40 300 -4.3 0 -4.2 -4.4 11/20/2005 07:00:00 2.7 0.5 3.8 1.1 2.7 0.5 3.8 0.7 1.6 0.5 3 0.4 55 9 47 300 -4.5 0 -4.4 -4.6 11/20/2005 07:10:00 2.7 0.4 3.4 1.5 2.7 0.5 3.4 1.1 1.3 0.6 2.6 0.4 47 7 49 300 -4.7 0 -4.6 -4.8 11/20/2005 07:20:00 2.2 0.4 3.4 1.1 2 0.5 3.4 0.4 1.1 0.5 2.6 0.4 37 10 47 300 -4.6 0 -4.6 -4.6 11/20/2005 07:30:00 2.7 0.5 3.8 1.1 2.4 0.6 3.8 0.4 1.5 0.6 2.6 0.4 37 9 29 300 -4.6 0 -4.6 -4.6 11/20/2005 07:40:00 2.3 0.5 3.4 0.7 1.9 0.5 3.4 0.4 1.1 0.5 2.6 0.4 32 11 45 300 -4.7 0 -4.6 -4.6 11/20/2005 07:50:00 3.3 0.5 4.6 2.3 2.8 0.5 4.2 1.5 1.8 0.5 3.4 0.4 28 9 34 300 -4.6 0 -4.6 -4.6 11/20/2005 08:00:00 3.3 0.6 4.6 1.5 2.7 0.6 4.2 1.1 2.1 0.6 3.4 0.4 28 10 33 300 -4.4 0 -4.4 -4.6 11/20/2005 08:10:00 2.6 0.5 3.8 1.1 2.2 0.6 3.4 0.7 1.8 0.5 3.4 0.7 29 9 30 300 -4.3 0 -4.2 -4.4 11/20/2005 08:20:00 4.2 0.8 6.1 2.6 3.7 0.8 6.1 1.9 3 0.7 5.7 1.5 29 9 34 300 -4.1 0.2 -3.7 -4.4 11/20/2005 08:30:00 3.2 0.6 5.3 1.5 3 0.7 5.3 1.1 2.5 0.7 3.8 0.7 35 12 38 300 -3.8 0 -3.7 -3.7 11/20/2005 08:40:00 3.4 1 5.7 0.7 3.1 1 5.7 0.4 2.4 1 5.3 0.4 36 15 29 300 -3.7 0 -3.5 -3.7 11/20/2005 08:50:00 3.1 0.6 5.7 1.5 2.9 0.7 5.3 1.1 2.5 0.7 4.6 1.1 41 17 50 300 -3.5 0 -3.5 -3.5 11/20/2005 09:00:00 4.6 1.2 7.2 1.1 4.2 1.3 6.5 0.4 3.3 1 6.5 0.7 36 17 45 300 -3.4 0 -3.3 -3.5 11/20/2005 09:10:00 5.7 1.1 8 3 5 1.1 8.4 2.6 4.1 1 6.8 1.1 25 13 13 300 -3.2 0 -3.3 -3.3 11/20/2005 09:20:00 6 1 8.4 3 5.3 1 8.4 2.3 4.5 0.9 8 2.3 25 12 16 300 -3.2 0 -3.3 -3.3 11/20/2005 09:30:00 5.8 1 8.8 3.8 5.2 1.1 8.8 2.6 4.1 0.8 6.5 1.9 22 13 9 300 -3.2 0 -3.3 -3.3 11/20/2005 09:40:00 5.4 0.9 8 2.6 4.9 0.9 7.6 2.6 4.1 1 7.2 1.9 29 12 20 300 -3.2 0 -3 -3.3 11/20/2005 09:50:00 4.8 0.9 7.2 2.3 4.2 1 6.8 1.5 3.6 1 6.8 1.1 25 10 26 300 -3.1 0 -3 -3.3 11/20/2005 10:00:00 4.6 0.8 6.8 3 4.1 0.8 6.1 1.9 3.4 0.8 6.1 1.5 21 12 22 300 -3.1 0 -3 -3.3 11/20/2005 10:10:00 5.3 1 8.4 3 4.6 1 8 2.3 4 1 7.2 1.9 21 10 25 300 -3.1 0 -3 -3.3 11/20/2005 10:20:00 4.8 1.1 6.8 2.3 4.3 1.1 6.8 1.9 3.4 1 6.1 1.5 19 16 8 300 -3 0 -2.8 -3 11/20/2005 10:30:00 4.7 0.9 7.2 2.6 4.2 0.9 6.5 1.9 3.4 0.8 6.1 1.5 17 12 18 300 -3 0 -2.8 -3 11/20/2005 10:40:00 5 1.1 7.6 2.3 4.4 1.1 7.2 1.5 3.8 0.9 6.5 1.5 27 14 17 300 -2.9 0 -2.8 -3 11/20/2005 10:50:00 5.8 0.9 8 3.8 5.1 1 7.6 3 4.2 0.9 6.5 2.3 24 12 33 300 -2.9 0 -2.8 -3 11/20/2005 11:00:00 6.1 1 9.9 3.4 5.4 1 8.4 2.6 4.9 0.9 7.6 2.6 29 13 32 300 -3 0 -2.8 -3 11/20/2005 11:10:00 6.2 1.2 8.8 3 5.5 1.2 8.4 2.6 4.7 1.2 8.8 2.3 25 12 23 300 -3 0 -2.8 -3 11/20/2005 11:20:00 6.4 1.1 9.1 3 5.7 1.1 8.4 3 4.8 1 7.6 1.1 22 13 19 300 -3 0 -2.8 -3 11/20/2005 11:30:00 5.8 1.1 8.8 3.4 5.2 1.2 8 2.3 4.3 1.1 8.8 1.9 23 13 20 300 -2.9 0 -2.8 -3 11/20/2005 11:40:00 6.1 1.3 8.8 3 5.4 1.2 8.4 2.6 4.5 1.2 7.6 1.5 23 15 31 300 -2.8 0 -2.6 -2.8 11/20/2005 11:50:00 5.3 1.1 8.4 3 4.8 1.2 8 1.9 4.1 1 7.2 1.9 28 14 26 300 -2.6 0 -2.6 -2.8 11/20/2005 12:00:00 6.4 1.1 8.8 3.8 5.7 1.1 8.8 3 4.7 1.1 8.4 2.3 26 11 20 300 -2.6 0 -2.6 -2.6 11/20/2005 12:10:00 6.6 1.2 9.1 3.4 5.8 1.2 8.8 1.9 4.9 1.2 8.8 2.3 27 12 20 300 -2.4 0 -2.1 -2.6 11/20/2005 12:20:00 6.6 1 8.8 3.8 5.7 1 8.4 3 4.9 1.1 8.4 2.6 29 11 18 300 -2.3 0 -2.1 -2.4 11/20/2005 12:30:00 5.8 1.2 8.4 2.6 5.3 1.2 8 1.9 4.3 1 7.6 1.9 30 15 24 300 -2.1 0 -2.1 -2.1 11/20/2005 12:40:00 5.3 1.1 8 2.3 4.8 1.1 6.8 1.5 4 1 6.5 1.5 34 14 26 300 -2.1 0 -2.1 -2.1 11/20/2005 12:50:00 6.3 1.2 9.1 3.4 5.6 1.2 8.8 2.6 4.6 1.1 7.2 1.9 31 13 31 300 -2.1 0 -1.9 -2.1 11/20/2005 13:00:00 7.1 1.2 11.1 4.2 6.5 1.3 10.7 3.8 5.5 1.1 9.9 3 29 14 33 300 -2.1 0 -1.9 -2.1 11/20/2005 13:10:00 7.2 1.2 10.3 4.6 6.4 1.2 9.5 3.4 5.5 1.1 8.4 2.6 30 11 21 300 -2 0 -1.7 -2.1 11/20/2005 13:20:00 8 1.3 11.8 4.6 7.2 1.4 11.5 3.8 6.1 1.4 9.5 2.3 32 11 35 300 -1.7 0 -1.7 -1.9 11/20/2005 13:30:00 7.6 1.3 11.1 4.2 6.9 1.5 11.1 3 5.8 1.4 9.5 2.3 32 13 39 300 -2.1 0 -1.9 -2.1 11/20/2005 13:40:00 7.5 1.4 11.1 4.6 7 1.5 10.7 3.4 6 1.5 10.7 2.6 33 12 42 300 -2.1 0 -1.9 -2.1 11/20/2005 13:50:00 8.2 1.2 11.8 4.9 7.8 1.3 11.5 4.6 6.5 1.5 10.7 3.4 36 11 40 300 -2 0.1 -1.7 -2.1 11/20/2005 14:00:00 8 1.3 11.8 2.6 7.7 1.5 11.1 3.4 6.1 1.6 10.3 2.6 38 12 25 300 -1.7 0 -1.4 -1.9 11/20/2005 14:10:00 8.2 1.3 11.8 4.9 7.8 1.4 11.8 4.2 6.4 1.6 10.7 2.6 37 11 40 300 -1.6 0 -1.4 -1.7 11/20/2005 14:20:00 7.1 1.1 9.9 4.2 6.8 1.3 9.9 3.4 5.5 1.2 8.4 2.6 38 12 28 300 -1.5 0 -1.4 -1.4 11/20/2005 14:30:00 7 1.2 10.3 4.2 6.6 1.3 9.9 3.8 5.5 1.2 9.1 2.6 38 12 18 300 -1.3 0 -1.2 -1.4 11/20/2005 14:40:00 6.8 1 8.8 4.2 6.4 1.1 9.1 3.4 5.1 1.1 8 2.3 39 13 55 300 -1.3 0 -1.2 -1.4 11/20/2005 14:50:00 6.4 1.2 9.5 2.6 6.2 1.2 9.5 3 4.9 1.3 8.4 1.5 44 13 39 300 -1.1 0 -1 -1.4 11/20/2005 15:00:00 4.4 1.2 8 1.1 4.2 1.2 8 0.7 3.2 1 6.5 0.7 50 23 36 300 -1 0 -1 -1.2 11/20/2005 15:10:00 2.2 0.9 5.7 0.4 2.1 1 5.3 0.4 2 0.8 4.9 0.4 141 51 45 300 -1.6 0.3 -1.2 -2.1 11/20/2005 15:20:00 0.9 0.4 1.9 0.4 0.6 0.3 1.5 0.4 0.8 0.4 1.9 0.4 182 6 193 300 -2.5 0.1 -2.1 -2.6 11/20/2005 15:30:00 1.8 0.4 2.6 0.7 2.1 0.5 3 0.7 1.8 0.6 3 0.4 203 15 191 300 -2.8 0 -2.6 -2.8 11/20/2005 15:40:00 1.1 0.6 2.6 0.4 1.1 0.6 2.6 0.4 0.8 0.6 2.3 0.4 219 5 218 300 -2.9 0.1 -2.6 -3 11/20/2005 15:50:00 0.7 0.4 1.9 0.4 0.6 0.3 1.5 0.4 0.6 0.3 1.5 0.4 256 43 224 300 -3.1 0 -3 -3.3 11/20/2005 16:00:00 0.6 0.4 2.3 0.4 0.5 0.3 2.3 0.4 0.7 0.4 2.3 0.4 75 98 50 300 -3.1 0 -3 -3.3 11/20/2005 16:10:00 1.9 0.7 3.4 0.4 1.7 0.7 3 0.4 1.4 0.6 3.4 0.4 42 19 35 300 -3.1 0 -2.8 -3.3 11/20/2005 16:20:00 2 0.6 3.8 0.7 1.9 0.6 3.8 0.4 1.5 0.5 3.4 0.4 71 17 54 300 -2.9 0 -2.8 -3 11/20/2005 16:30:00 1 0.6 3.4 0.4 0.9 0.6 3.4 0.4 1.1 0.4 2.6 0.4 130 36 81 300 -3.1 0 -2.8 -3.5 11/20/2005 16:40:00 0.7 0.4 1.9 0.4 0.6 0.3 1.5 0.4 0.9 0.4 1.9 0.4 165 27 154 300 -3.4 0 -3.3 -3.5 11/20/2005 16:50:00 0.4 0.1 1.1 0.4 0.4 0.1 1.1 0.4 0.5 0.3 1.5 0.4 138 36 55 300 -3.4 0 -3.3 -3.5 11/20/2005 17:00:00 0.6 0.3 1.5 0.4 0.5 0.2 1.1 0.4 0.5 0.2 1.1 0.4 174 0 174 300 -3.6 0 -3.5 -3.7 11/20/2005 17:10:00 0.4 0 0.7 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 174 0 174 300 -3.8 0 -3.5 -3.9 11/20/2005 17:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0.1 1.1 0.4 122 82 300 300 -3.8 0 -3.7 -3.9 11/20/2005 17:30:00 0.8 0.4 1.9 0.4 0.6 0.4 1.5 0.4 1 0.4 1.9 0.4 354 2 356 300 -3.8 0 -3.7 -3.9 11/20/2005 17:40:00 0.6 0.3 1.5 0.4 0.5 0.2 1.1 0.4 0.6 0.3 1.5 0.4 14 19 357 300 -3.8 0 -3.7 -3.9 11/20/2005 17:50:00 0.5 0.2 1.1 0.4 0.4 0.1 0.7 0.4 0.5 0.3 1.1 0.4 9 5 356 300 -3.9 0 -3.7 -3.9 11/20/2005 18:00:00 0.6 0.5 2.3 0.4 0.6 0.4 2.3 0.4 0.7 0.5 2.3 0.4 274 102 181 300 -3.9 0 -3.7 -3.9 11/20/2005 18:10:00 1.7 0.3 2.6 1.1 1.6 0.3 2.3 1.1 1.4 0.5 2.3 0.4 177 6 181 300 -3.8 0 -3.5 -3.9 11/20/2005 18:20:00 1.3 0.5 2.3 0.4 1.2 0.5 2.3 0.4 0.9 0.5 1.9 0.4 162 12 161 300 -3.8 0 -3.7 -3.7 11/20/2005 18:30:00 1.3 0.4 2.6 0.4 1.2 0.5 2.3 0.4 0.8 0.4 1.9 0.4 169 13 169 300 -3.7 0 -3.5 -3.7 11/20/2005 18:40:00 1.5 0.5 2.6 0.4 1.5 0.4 2.6 0.4 1.1 0.5 2.3 0.4 189 8 183 300 -3.5 0 -3.3 -3.5 11/20/2005 18:50:00 0.8 0.4 1.5 0.4 0.7 0.3 1.5 0.4 0.6 0.3 1.5 0.4 193 12 185 300 -3.4 0 -3.3 -3.5 11/20/2005 19:00:00 0.9 0.4 1.9 0.4 0.9 0.4 1.9 0.4 0.9 0.4 2.3 0.4 210 8 216 300 -3.4 0 -3.3 -3.5 11/20/2005 19:10:00 1.4 0.3 2.3 0.7 1.5 0.4 2.3 0.4 1.4 0.4 2.6 0.4 206 9 195 300 -3.3 0 -3.3 -3.5 11/20/2005 19:20:00 0.8 0.4 1.5 0.4 0.8 0.5 1.9 0.4 0.6 0.4 1.9 0.4 209 11 195 300 -3.4 0 -3.3 -3.5 11/20/2005 19:30:00 1.3 0.5 2.3 0.4 1.4 0.5 2.3 0.4 1.2 0.5 1.9 0.4 219 11 223 300 -3.4 0 -3.3 -3.5 11/20/2005 19:40:00 1.4 0.7 3 0.4 1.4 0.7 3 0.4 1.2 0.8 3 0.4 223 11 237 300 -3.4 0 -3.3 -3.5 11/20/2005 19:50:00 1.7 0.3 2.6 1.1 1.9 0.4 2.6 1.1 1.7 0.4 2.6 0.4 209 10 227 300 -3.4 0 -3.3 -3.5 11/20/2005 20:00:00 1.9 0.6 3.4 0.7 2 0.5 3.4 0.7 1.8 0.6 3.4 0.4 218 9 224 300 -3.5 0 -3.3 -3.5 11/20/2005 20:10:00 1.8 0.5 3 0.7 1.8 0.5 3 0.4 1.5 0.6 2.6 0.4 228 15 240 300 -3.5 0 -3.5 -3.5 11/20/2005 20:20:00 2.2 0.3 3 1.5 2.1 0.4 3 1.1 1.9 0.4 3 0.7 230 9 222 300 -3.6 0 -3.5 -3.7 11/20/2005 20:30:00 1.6 0.6 2.6 0.4 1.6 0.5 2.6 0.4 1.6 0.5 2.6 0.4 221 18 241 300 -3.7 0 -3.5 -3.7 11/20/2005 20:40:00 1.2 0.6 2.6 0.4 1.1 0.6 2.6 0.4 1 0.5 2.3 0.4 219 11 228 300 -3.8 0 -3.5 -3.7 11/20/2005 20:50:00 0.7 0.4 1.5 0.4 0.6 0.4 1.5 0.4 0.6 0.4 1.9 0.4 223 7 237 300 -3.8 0 -3.7 -3.9 11/20/2005 21:00:00 0.5 0.3 1.5 0.4 0.4 0.2 1.1 0.4 0.4 0.1 1.1 0.4 236 15 236 300 -3.9 0 -3.7 -3.9 11/20/2005 21:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0.1 0.7 0.4 318 10 300 300 -4 0 -3.9 -4.2 11/20/2005 21:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 324 0 300 300 -3.9 0 -3.7 -3.9 11/20/2005 21:30:00 0.4 0.1 0.7 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 266 30 260 300 -4 0 -3.9 -4.2 11/20/2005 21:40:00 0.7 0.6 2.6 0.4 0.6 0.5 2.3 0.4 0.7 0.6 2.3 0.4 243 8 226 300 -4 0 -3.9 -4.2 11/20/2005 21:50:00 1.5 0.5 3 0.4 1.4 0.6 2.6 0.4 1.3 0.6 2.6 0.4 236 19 220 300 -4.2 0 -3.9 -4.4 11/20/2005 22:00:00 1.8 0.4 2.6 0.7 1.6 0.5 2.6 0.7 1.4 0.4 2.6 0.7 246 13 228 300 -4 0 -3.9 -4.2 11/20/2005 22:10:00 1 0.4 1.9 0.4 1 0.5 1.9 0.4 0.8 0.4 1.9 0.4 210 17 233 300 -4.1 0 -3.9 -4.4 11/20/2005 22:20:00 0.9 0.4 1.9 0.4 1 0.5 1.9 0.4 0.9 0.5 2.3 0.4 200 5 206 300 -4.3 0 -4.2 -4.4 11/20/2005 22:30:00 0.8 0.3 1.5 0.4 0.9 0.4 1.9 0.4 0.8 0.4 1.9 0.4 208 10 198 300 -4.3 0 -4.2 -4.4 11/20/2005 22:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 202 7 300 300 -4.4 0 -4.4 -4.6 11/20/2005 22:50:00 0.6 0.4 1.9 0.4 0.5 0.3 1.9 0.4 0.4 0.2 1.5 0.4 225 14 246 300 -4.7 0.1 -4.4 -4.8 11/20/2005 23:00:00 1.4 0.6 2.6 0.4 1.2 0.6 2.6 0.4 1 0.6 2.3 0.4 246 16 233 300 -4.8 0 -4.6 -4.8 11/20/2005 23:10:00 1.7 0.4 3 0.7 1.5 0.5 2.6 0.4 1.3 0.5 2.3 0.4 245 11 241 300 -4.7 0 -4.4 -4.8 11/20/2005 23:20:00 1.7 0.4 2.6 0.7 1.6 0.4 2.6 0.7 1.4 0.4 2.6 0.4 229 7 241 300 -4.4 0 -4.4 -4.6 11/20/2005 23:30:00 2 0.3 2.6 1.1 1.9 0.3 2.6 1.1 1.6 0.3 2.6 0.7 230 7 228 300 -4.3 0 -4.4 -4.4 11/20/2005 23:40:00 1.7 0.5 2.6 0.4 1.4 0.6 2.6 0.4 1.2 0.5 2.3 0.4 248 12 242 300 -4.3 0 -4.4 -4.4 11/20/2005 23:50:00 1 0.6 2.3 0.4 0.9 0.5 1.9 0.4 0.7 0.4 1.9 0.4 232 9 245 300 -4.3 0 -4.4 -4.6 11/21/2005 00:00:00 0.9 0.5 1.9 0.4 0.9 0.5 1.9 0.4 0.9 0.5 1.9 0.4 219 8 213 300 -4.5 0 -3.9 -4.6 11/21/2005 00:10:00 1.2 0.2 1.5 0.4 0.9 0.3 1.5 0.4 0.9 0.3 1.5 0.4 242 13 215 300 -4.4 0 -4.4 -4.6 11/21/2005 00:20:00 1.8 0.4 2.6 1.1 1.7 0.4 2.6 0.7 1.6 0.4 2.3 0.4 226 8 223 300 -4.3 0 -4.4 -4.4 11/21/2005 00:30:00 1.6 0.4 2.6 0.7 1.7 0.3 2.3 1.1 1.2 0.4 2.3 0.4 221 10 233 300 -4.3 0 -4.4 -4.4 11/21/2005 00:40:00 1 0.4 2.3 0.4 1.2 0.5 2.3 0.4 0.8 0.4 1.9 0.4 207 7 234 300 -4.3 0 -4.4 -4.6 11/21/2005 00:50:00 1.3 0.7 3.4 0.4 1.4 0.7 3 0.4 1.2 0.8 3.4 0.4 205 14 188 300 -4.3 0 -4.2 -4.4 11/21/2005 01:00:00 1.8 0.6 3.8 0.7 2.1 0.7 3.8 0.7 1.8 0.7 3.4 0.4 203 11 200 300 -4.2 0 -3.9 -4.4 11/21/2005 01:10:00 2.1 0.8 4.2 0.4 2.3 0.8 4.2 0.4 1.7 0.9 3.8 0.4 201 13 232 300 -3.9 0 -3.9 -4.2 11/21/2005 01:20:00 2.3 0.5 3.8 1.1 2.5 0.6 3.8 1.1 2 0.5 3.4 0.7 198 12 189 300 -3.8 0 -3.7 -3.9 11/21/2005 01:30:00 2.6 0.8 4.6 0.4 3 1 4.6 0.4 2.6 1 4.6 0.4 213 13 203 300 -3.9 0 -3.7 -3.9 11/21/2005 01:40:00 1.7 0.7 3.4 0.4 1.9 0.8 3.4 0.4 1.6 0.7 3.4 0.4 216 13 222 300 -4 0 -3.9 -4.2 11/21/2005 01:50:00 1.8 0.6 3.8 0.4 1.9 0.6 3.8 0.4 1.6 0.7 3.4 0.4 219 17 242 300 -4.1 0 -3.9 -4.2 11/21/2005 02:00:00 1.8 0.5 3 0.4 2 0.6 3.4 0.7 1.5 0.7 3 0.4 222 13 236 300 -4.2 0 -3.9 -4.2 11/21/2005 02:10:00 1.8 0.7 4.2 0.4 1.8 0.7 3.8 0.4 1.5 0.7 4.2 0.4 227 15 233 300 -4.2 0 -3.9 -4.4 11/21/2005 02:20:00 2.7 0.6 4.2 1.1 2.7 0.6 4.2 1.5 2.1 0.6 3.8 0.4 230 13 227 300 -4.3 0 -4.2 -4.4 11/21/2005 02:30:00 2.2 0.6 3.4 0.7 2.1 0.6 3 0.4 1.9 0.6 3 0.4 226 16 231 300 -4.4 0 -4.4 -4.6 11/21/2005 02:40:00 2.5 0.6 4.2 0.7 2.5 0.6 4.2 0.7 2.3 0.6 3.8 0.4 227 11 218 300 -4.5 0 -4.4 -4.6 11/21/2005 02:50:00 2 0.5 3.4 0.7 2 0.5 3.4 0.7 1.6 0.5 2.6 0.4 223 11 223 300 -4.7 0 -4.6 -4.8 11/21/2005 03:00:00 1.5 0.5 3 0.4 1.3 0.5 2.6 0.4 1.1 0.5 2.3 0.4 233 15 226 300 -4.7 0 -4.6 -4.8 11/21/2005 03:10:00 1.6 0.5 3 0.4 1.5 0.6 3 0.4 1.3 0.5 2.3 0.4 253 17 247 300 -4.8 0 -4.6 -4.8 11/21/2005 03:20:00 1.6 0.5 3 0.4 1.4 0.5 2.6 0.4 1.1 0.6 2.3 0.4 255 12 259 300 -4.8 0 -4.6 -4.8 11/21/2005 03:30:00 1.4 0.5 2.3 0.4 1.2 0.5 2.3 0.4 1.2 0.5 2.3 0.4 276 13 257 300 -4.9 0 -4.8 -5 11/21/2005 03:40:00 0.8 0.6 1.9 0.4 0.7 0.5 1.9 0.4 0.7 0.5 1.9 0.4 278 4 277 300 -5.1 0 -5 -5.3 11/21/2005 03:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 277 0 300 300 -5.3 0 -5 -5.5 11/21/2005 04:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 277 0 300 300 -5.4 0 -5.3 -5.5 11/21/2005 04:10:00 0.4 0.1 1.1 0.4 0.4 0 0.4 0.4 0.4 0.2 1.1 0.4 336 36 16 300 -5.5 0 -5.5 -5.7 11/21/2005 04:20:00 0.5 0.2 1.1 0.4 0.4 0.1 1.1 0.4 0.7 0.2 1.1 0.4 18 0 16 300 -5.6 0 -5.5 -5.7 11/21/2005 04:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0.1 0.7 0.4 18 0 300 300 -5.8 0 -5.7 -5.9 11/21/2005 04:40:00 0.5 0.2 1.1 0.4 0.4 0.1 0.7 0.4 0.4 0.2 1.1 0.4 37 24 73 300 -5.9 0 -5.7 -5.9 11/21/2005 04:50:00 0.7 0.3 1.5 0.4 0.6 0.3 1.1 0.4 0.9 0.3 1.5 0.4 118 20 109 300 -5.9 0 -5.7 -5.9 11/21/2005 05:00:00 0.5 0.3 1.1 0.4 0.4 0.1 0.7 0.4 0.7 0.3 1.5 0.4 124 11 133 300 -5.9 0 -5.7 -5.9 11/21/2005 05:10:00 0.4 0.1 1.1 0.4 0.4 0.1 0.7 0.4 1.2 0.2 1.5 0.7 74 0 74 300 -6 0 -5.7 -5.9 11/21/2005 05:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.8 0.2 1.1 0.4 74 0 300 300 -6 0 -5.9 -5.9 11/21/2005 05:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.9 0.2 1.5 0.7 74 0 300 300 -6 0 -5.7 -5.9 11/21/2005 05:40:00 0.4 0.2 1.1 0.4 0.4 0.1 1.1 0.4 1.2 0.2 1.9 0.7 63 11 55 300 -6 0 -5.7 -5.9 11/21/2005 05:50:00 0.8 0.4 1.5 0.4 0.7 0.3 1.5 0.4 1.5 0.2 1.9 1.1 44 4 36 300 -6 0 -5.9 -6.1 11/21/2005 06:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 1 0.2 1.5 0.7 46 0 300 300 -6 0 -5.9 -6.1 11/21/2005 06:10:00 0.6 0.4 1.9 0.4 0.6 0.4 1.5 0.4 1.3 0.3 1.9 0.7 46 0 46 300 -6.3 0 -6.1 -6.6 11/21/2005 06:20:00 2 0.2 2.3 1.5 1.9 0.2 2.3 1.1 1.5 0.3 1.9 0.7 40 4 43 300 -6.4 0 -6.1 -6.6 11/21/2005 06:30:00 1.8 0.2 2.3 1.1 1.6 0.3 2.3 1.1 1.2 0.2 1.9 0.7 34 0 34 300 -6.3 0 -6.1 -6.4 11/21/2005 06:40:00 0.9 0.3 1.9 0.4 0.7 0.3 1.5 0.4 0.9 0.2 1.5 0.4 24 6 34 300 -6.4 0.1 -6.1 -6.6 11/21/2005 06:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.7 0.2 1.1 0.4 18 0 300 300 -6.5 0 -6.4 -6.6 11/21/2005 07:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0.2 0.7 0.4 18 0 300 300 -6.5 0 -6.6 -6.6 11/21/2005 07:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.7 0.4 1.5 0.4 18 0 300 300 -6.7 0 -6.6 -6.8 11/21/2005 07:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0.1 0.7 0.4 18 0 300 300 -6.8 0.1 -6.6 -7 11/21/2005 07:30:00 0.4 0.2 1.1 0.4 0.4 0.1 0.7 0.4 0.8 0.5 2.3 0.4 18 0 18 300 -7.1 0 -6.8 -7 11/21/2005 07:40:00 0.8 0.3 1.5 0.4 0.6 0.3 1.5 0.4 1.4 0.3 2.3 0.7 27 12 53 300 -6.7 0.2 -6.6 -7 11/21/2005 07:50:00 0.9 0.5 1.9 0.4 0.9 0.5 1.9 0.4 1.3 0.7 2.3 0.4 54 1 53 300 -6.9 0.1 -6.6 -7 11/21/2005 08:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0.3 1.9 0.4 55 0 300 300 -7.1 0 -6.8 -7 11/21/2005 08:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0.2 1.1 0.4 55 0 300 300 -7.1 0 -6.8 -7.4 11/21/2005 08:20:00 0.5 0.3 1.5 0.4 0.4 0.2 1.1 0.4 0.8 0.3 1.5 0.4 52 6 41 300 -7.1 0 -7 -7.2 11/21/2005 08:30:00 1.5 0.2 1.9 1.1 1.3 0.2 1.5 0.7 1.3 0.3 1.9 0.7 40 2 41 300 -7.1 0 -7 -7.2 11/21/2005 08:40:00 1.4 0.3 1.9 0.7 1.2 0.3 1.9 0.7 1.3 0.3 1.9 0.7 39 4 36 300 -7.1 0 -6.8 -7.2 11/21/2005 08:50:00 1.7 0.2 2.3 1.1 1.6 0.3 2.3 1.1 1.9 0.2 2.3 1.5 55 1 54 300 -7.1 0 -6.8 -7 11/21/2005 09:00:00 1.4 0.2 1.9 0.7 1.2 0.2 1.5 0.7 1.5 0.2 1.9 1.1 55 1 56 300 -6.9 0.1 -6.6 -7.2 11/21/2005 09:10:00 0.9 0.2 1.1 0.4 0.7 0.2 1.1 0.4 1.2 0.2 1.5 0.7 52 3 53 300 -6.9 0.1 -6.6 -7 11/21/2005 09:20:00 0.8 0.1 1.1 0.4 0.5 0.2 0.7 0.4 0.9 0.2 1.5 0.4 49 0 49 300 -7 0 -6.8 -7 11/21/2005 09:30:00 0.5 0.2 1.1 0.4 0.4 0.1 0.7 0.4 0.4 0.2 1.1 0.4 49 0 49 300 -6.9 0 -6.8 -7 11/21/2005 09:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.6 0.3 1.1 0.4 36 14 300 300 -6.7 0 -6.6 -6.8 11/21/2005 09:50:00 0.4 0.1 1.1 0.4 0.4 0.1 0.7 0.4 0.9 0.2 1.5 0.7 16 4 3 300 -6.6 0 -6.6 -6.6 11/21/2005 10:00:00 1 0.2 1.5 0.7 0.9 0.2 1.1 0.4 1.5 0.2 1.9 1.1 359 1 359 300 -6.6 0 -6.4 -7.2 11/21/2005 10:10:00 0.6 0.3 1.1 0.4 0.5 0.2 1.1 0.4 1 0.2 1.5 0.7 358 0 359 300 -6.4 0 -6.4 -6.6 11/21/2005 10:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.5 0.3 1.1 0.4 359 0 300 300 -6.4 0 -6.4 -6.6 11/21/2005 10:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.7 0.3 1.1 0.4 359 0 300 300 -6.4 0 -6.1 -6.6 11/21/2005 10:40:00 0.7 0.4 1.5 0.4 0.5 0.3 1.1 0.4 1.2 0.5 2.3 0.4 0 3 359 300 -6.2 0 -5.9 -6.4 11/21/2005 10:50:00 0.7 0.3 1.1 0.4 0.5 0.2 1.1 0.4 1 0.3 1.5 0.4 2 17 9 300 -6 0 -5.7 -6.1 11/21/2005 11:00:00 0.4 0.2 1.1 0.4 0.4 0.1 0.7 0.4 0.5 0.3 1.5 0.4 326 1 328 300 -5.7 0 -5.5 -5.9 11/21/2005 11:10:00 0.6 0.3 1.5 0.4 0.5 0.3 1.5 0.4 0.7 0.4 1.5 0.4 308 19 281 300 -5.4 0 -5.5 -5.5 11/21/2005 11:20:00 1.3 0.2 1.9 0.4 1.1 0.2 1.5 0.4 1.1 0.3 1.9 0.4 272 4 278 300 -5.4 0 -5 -5.5 11/21/2005 11:30:00 0.6 0.4 1.5 0.4 0.6 0.3 1.5 0.4 0.4 0.1 0.7 0.4 270 3 265 300 -5 0.1 -4.8 -5.3 11/21/2005 11:40:00 0.6 0.2 1.1 0.4 0.5 0.2 1.1 0.4 0.6 0.3 1.1 0.4 277 8 289 300 -4.8 0 -4.6 -4.8 11/21/2005 11:50:00 0.9 0.4 1.5 0.4 0.8 0.3 1.5 0.4 0.7 0.3 1.1 0.4 277 13 268 300 -4.8 0 -4.6 -4.8 11/21/2005 12:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 299 2 300 300 -4.6 0 -4.4 -4.8 11/21/2005 12:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 288 0 300 300 -4.3 0 -4.4 -4.6 11/21/2005 12:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 288 0 300 300 -4.3 0 -4.4 -4.6 11/21/2005 12:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 288 0 300 300 -4.4 0 -4.4 -4.6 11/21/2005 12:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.7 0.4 329 22 300 300 -4.3 0 -4.4 -4.4 11/21/2005 12:50:00 0.4 0.1 1.1 0.4 0.4 0.1 1.1 0.4 0.6 0.2 1.1 0.4 11 19 24 300 -4.3 0 -4.2 -4.4 11/21/2005 13:00:00 0.8 0.2 1.1 0.4 0.7 0.2 1.1 0.4 0.8 0.3 1.5 0.4 44 11 24 300 -4.1 0 -3.9 -4.4 11/21/2005 13:10:00 0.5 0.2 1.1 0.4 0.5 0.2 1.1 0.4 0.6 0.3 1.5 0.4 57 3 54 300 -4 0 -3.7 -3.9 11/21/2005 13:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 60 0 300 300 -3.8 0 -3.7 -3.9 11/21/2005 13:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 30 35 300 300 -3.8 0 -3.7 -3.7 11/21/2005 13:40:00 0.4 0 0.4 0.4 0.4 0 0.7 0.4 0.4 0 0.7 0.4 345 5 300 300 -3.8 0 -3.5 -3.7 11/21/2005 13:50:00 0.4 0.1 1.1 0.4 0.4 0.1 0.7 0.4 0.5 0.2 1.1 0.4 270 12 297 300 -3.7 0 -3.5 -3.7 11/21/2005 14:00:00 0.5 0.2 1.1 0.4 0.5 0.2 1.1 0.4 0.6 0.3 1.1 0.4 263 4 261 300 -3.7 0 -3.5 -3.7 11/21/2005 14:10:00 0.4 0.1 1.1 0.4 0.4 0.1 0.7 0.4 0.4 0.1 1.1 0.4 261 10 261 300 -3.6 0 -3.5 -3.7 11/21/2005 14:20:00 1 0.6 2.3 0.4 1 0.6 2.6 0.4 1.1 0.5 2.3 0.4 228 6 222 300 -3.6 0 -3.5 -3.7 11/21/2005 14:30:00 1.2 0.4 2.3 0.4 1.1 0.4 2.3 0.4 1.3 0.5 2.3 0.4 241 9 234 300 -3.6 0 -3.5 -3.7 11/21/2005 14:40:00 0.8 0.4 1.9 0.4 0.7 0.4 1.9 0.4 0.8 0.4 1.9 0.4 235 11 217 300 -3.6 0 -3.5 -3.7 11/21/2005 14:50:00 0.6 0.3 1.5 0.4 0.5 0.3 1.5 0.4 0.6 0.3 1.5 0.4 248 8 241 300 -3.6 0 -3.5 -3.5 11/21/2005 15:00:00 0.5 0.2 1.1 0.4 0.4 0.2 1.1 0.4 0.5 0.2 1.1 0.4 249 9 249 300 -3.6 0 -3.5 -3.5 11/21/2005 15:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 254 0 300 300 -3.6 0 -3.5 -3.5 11/21/2005 15:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 254 0 300 300 -3.5 0 -3.5 -3.5 11/21/2005 15:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 254 0 300 300 -3.6 0 -3.5 -3.5 11/21/2005 15:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 254 0 300 300 -3.6 0 -3.5 -3.7 11/21/2005 15:50:00 0.5 0.2 1.1 0.4 0.5 0.2 1.1 0.4 0.6 0.3 1.5 0.4 299 72 254 300 -3.7 0 -3.5 -3.7 11/21/2005 16:00:00 1 0.4 1.9 0.4 0.9 0.4 1.9 0.4 0.7 0.4 1.5 0.4 52 11 52 300 -3.8 0 -3.5 -3.7 11/21/2005 16:10:00 0.4 0.2 1.1 0.4 0.4 0.1 1.1 0.4 0.4 0.1 1.1 0.4 71 17 79 300 -3.8 0 -3.7 -3.7 11/21/2005 16:20:00 0.7 0.4 1.5 0.4 0.6 0.3 1.5 0.4 0.6 0.3 1.5 0.4 54 12 57 300 -3.8 0 -3.7 -3.7 11/21/2005 16:30:00 0.7 0.4 1.5 0.4 0.6 0.3 1.5 0.4 0.5 0.3 1.5 0.4 49 10 44 300 -3.8 0 -3.7 -3.9 11/21/2005 16:40:00 0.5 0.2 1.1 0.4 0.4 0.2 1.1 0.4 0.4 0.2 1.1 0.4 51 4 42 300 -3.8 0 -3.7 -3.9 11/21/2005 16:50:00 0.7 0.4 1.5 0.4 0.6 0.3 1.5 0.4 0.4 0.2 1.1 0.4 38 1 37 300 -3.8 0 -3.7 -3.9 11/21/2005 17:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 40 0 300 300 -3.8 0 -3.7 -3.9 11/21/2005 17:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 40 0 300 300 -3.8 0 -3.7 -3.9 11/21/2005 17:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 40 0 300 300 -3.8 0 -3.7 -3.9 11/21/2005 17:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 40 0 300 300 -3.8 0 -3.7 -3.9 11/21/2005 17:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 40 0 300 300 -3.8 0 -3.7 -3.9 11/21/2005 17:50:00 0.4 0.1 1.1 0.4 0.4 0.1 0.7 0.4 0.4 0.2 1.1 0.4 40 0 40 300 -3.8 0 -3.7 -3.9 11/21/2005 18:00:00 1.1 0.3 1.5 0.4 0.9 0.3 1.5 0.4 1 0.2 1.5 0.7 44 3 47 300 -3.8 0 -3.7 -3.9 11/21/2005 18:10:00 1 0.2 1.5 0.4 0.8 0.3 1.5 0.4 0.9 0.2 1.5 0.4 47 1 46 300 -3.8 0 -3.7 -3.9 11/21/2005 18:20:00 1.2 0.3 1.9 0.4 1.1 0.3 1.5 0.4 0.9 0.4 1.9 0.4 51 3 53 300 -3.8 0 -3.7 -3.9 11/21/2005 18:30:00 0.7 0.3 1.5 0.4 0.6 0.3 1.5 0.4 0.4 0.2 1.1 0.4 53 11 71 300 -3.9 0 -3.7 -3.9 11/21/2005 18:40:00 0.4 0.1 1.1 0.4 0.4 0.1 1.1 0.4 0.4 0.1 0.7 0.4 43 7 57 300 -3.9 0 -3.7 -3.9 11/21/2005 18:50:00 0.4 0.1 0.7 0.4 0.4 0.1 0.7 0.4 0.4 0 0.4 0.4 27 13 11 300 -3.9 0 -3.7 -3.9 11/21/2005 19:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0.1 0.7 0.4 11 0 300 300 -3.9 0 -3.7 -3.9 11/21/2005 19:10:00 0.4 0 0.4 0.4 0.4 0 0.7 0.4 0.5 0.2 1.1 0.4 11 0 300 300 -3.9 0 -3.7 -3.9 11/21/2005 19:20:00 0.4 0 0.4 0.4 0.4 0 0.7 0.4 0.5 0.2 1.1 0.4 10 1 300 300 -3.9 0 -3.7 -3.9 11/21/2005 19:30:00 0.7 0.4 1.5 0.4 0.7 0.3 1.5 0.4 1 0.2 1.5 0.7 355 9 345 300 -3.8 0 -3.7 -3.9 11/21/2005 19:40:00 1 0.2 1.5 0.4 0.9 0.2 1.5 0.4 0.6 0.2 1.1 0.4 344 0 345 300 -3.8 0 -3.7 -3.9 11/21/2005 19:50:00 1 0.2 1.5 0.4 0.9 0.2 1.5 0.4 0.6 0.3 1.1 0.4 344 0 344 300 -3.9 0 -3.7 -3.9 11/21/2005 20:00:00 1.1 0.2 1.5 0.4 1 0.3 1.5 0.4 0.7 0.3 1.5 0.4 357 8 344 300 -3.9 0 -3.7 -3.9 11/21/2005 20:10:00 1.2 0.3 1.9 0.4 1 0.3 1.5 0.4 0.8 0.4 1.5 0.4 6 3 5 300 -3.8 0 -3.7 -3.9 11/21/2005 20:20:00 0.4 0.2 1.1 0.4 0.4 0.1 1.1 0.4 0.4 0 0.7 0.4 6 9 11 300 -3.8 0 -3.7 -3.9 11/21/2005 20:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 358 2 300 300 -3.8 0 -3.7 -3.9 11/21/2005 20:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 358 0 300 300 -3.8 0 -3.7 -3.9 11/21/2005 20:50:00 0.7 0.3 1.5 0.4 0.6 0.3 1.1 0.4 0.6 0.2 1.1 0.4 358 0 358 300 -3.8 0 -3.7 -3.7 11/21/2005 21:00:00 0.9 0.3 1.5 0.4 0.7 0.3 1.1 0.4 0.4 0.2 1.1 0.4 1 5 358 300 -3.8 0 -3.7 -3.9 11/21/2005 21:10:00 0.5 0.3 1.5 0.4 0.4 0.1 1.1 0.4 0.6 0.3 1.1 0.4 27 10 24 300 -3.8 0 -3.7 -3.9 11/21/2005 21:20:00 0.4 0.1 0.7 0.4 0.4 0.1 0.7 0.4 0.4 0.1 1.1 0.4 22 6 15 300 -3.8 0 -3.7 -3.9 11/21/2005 21:30:00 0.9 0.3 1.5 0.4 0.7 0.3 1.1 0.4 0.5 0.2 1.1 0.4 25 3 25 300 -3.8 0 -3.7 -3.9 11/21/2005 21:40:00 0.6 0.3 1.5 0.4 0.6 0.3 1.1 0.4 0.5 0.2 1.1 0.4 19 8 14 300 -3.8 0 -3.7 -3.7 11/21/2005 21:50:00 0.7 0.3 1.1 0.4 0.6 0.2 1.1 0.4 0.6 0.3 1.1 0.4 29 4 34 300 -3.8 0 -3.5 -3.7 11/21/2005 22:00:00 1.1 0.4 1.9 0.4 1 0.3 1.5 0.4 0.9 0.3 1.5 0.4 31 4 31 300 -3.8 0 -3.5 -3.7 11/21/2005 22:10:00 1.5 0.3 2.3 0.7 1.2 0.4 2.3 0.4 1 0.4 1.9 0.4 36 10 54 300 -3.8 0 -3.7 -3.7 11/21/2005 22:20:00 1.4 0.5 2.3 0.4 1.1 0.5 2.3 0.4 0.9 0.4 2.3 0.4 42 7 39 300 -3.8 0 -3.7 -3.7 11/21/2005 22:30:00 2.1 0.4 3 1.1 1.9 0.4 2.6 0.7 1.4 0.4 2.3 0.4 40 6 38 300 -3.8 0 -3.7 -3.7 11/21/2005 22:40:00 1.2 0.6 2.6 0.4 1 0.6 2.3 0.4 0.8 0.5 2.3 0.4 58 20 36 300 -3.8 0 -3.7 -3.7 11/21/2005 22:50:00 1.3 0.4 2.3 0.4 1.1 0.4 1.9 0.4 0.8 0.5 1.9 0.4 66 13 74 300 -3.8 0 -3.5 -3.7 11/21/2005 23:00:00 1.9 0.4 3 0.7 1.8 0.4 2.6 0.7 1.2 0.5 2.6 0.4 53 9 54 300 -3.8 0 -3.5 -3.7 11/21/2005 23:10:00 1.5 0.4 2.6 0.4 1.3 0.5 2.6 0.4 0.8 0.4 1.9 0.4 41 11 49 300 -3.8 0 -3.5 -3.7 11/21/2005 23:20:00 1.9 0.3 2.6 0.7 1.7 0.4 2.6 0.4 1.2 0.4 2.3 0.4 37 6 30 300 -3.8 0 -3.5 -3.7 11/21/2005 23:30:00 2.1 0.4 3 1.1 1.9 0.5 3 0.7 1.3 0.4 2.6 0.4 36 7 40 300 -3.8 0 -3.5 -3.7 11/21/2005 23:40:00 2.3 0.4 3 1.1 2.2 0.5 3 0.7 1.7 0.4 2.6 0.7 43 8 49 300 -3.8 0 -3.5 -3.7 11/21/2005 23:50:00 2.4 0.4 3.4 1.5 2.2 0.5 3.4 1.1 1.6 0.5 2.6 0.7 41 10 41 300 -3.7 0 -3.5 -3.7 11/22/2005 00:00:00 2 0.4 2.6 1.1 1.8 0.4 2.6 0.7 1.3 0.5 2.6 0.4 47 9 46 300 -3.7 0 -3.5 -3.7 11/22/2005 00:10:00 1.7 0.5 3 0.4 1.6 0.6 2.6 0.4 1.1 0.6 2.6 0.4 52 10 48 300 -3.8 0 -3.5 -3.7 11/22/2005 00:20:00 1.6 0.5 3 0.4 1.5 0.6 3 0.4 1.1 0.6 3 0.4 52 9 49 300 -3.7 0 -3.5 -3.7 11/22/2005 00:30:00 1.6 0.5 2.6 0.4 1.5 0.6 2.6 0.4 1.2 0.5 2.3 0.4 58 11 65 300 -3.7 0 -3.5 -3.7 11/22/2005 00:40:00 1.4 0.5 2.6 0.4 1.2 0.6 2.6 0.4 1.1 0.5 2.6 0.4 55 15 64 300 -3.7 0 -3.5 -3.7 11/22/2005 00:50:00 1.6 0.5 2.6 0.4 1.4 0.5 2.6 0.4 1.3 0.6 2.6 0.4 53 9 48 300 -3.7 0 -3.5 -3.7 11/22/2005 01:00:00 1.2 0.4 2.3 0.4 1 0.4 2.3 0.4 0.8 0.4 1.5 0.4 52 9 56 300 -3.7 0 -3.5 -3.7 11/22/2005 01:10:00 1.4 0.3 2.3 0.7 1.3 0.3 1.9 0.7 1.1 0.4 1.9 0.4 46 5 51 300 -3.7 0 -3.5 -3.7 11/22/2005 01:20:00 1.5 0.2 2.3 0.7 1.3 0.3 1.9 0.4 1.1 0.3 1.9 0.4 46 6 50 300 -3.6 0 -3.5 -3.7 11/22/2005 01:30:00 1.3 0.3 2.3 0.4 1.1 0.3 1.9 0.4 0.7 0.3 1.5 0.4 38 6 43 300 -3.7 0 -3.5 -3.7 11/22/2005 01:40:00 1.2 0.3 1.9 0.4 1 0.3 1.9 0.4 0.8 0.3 1.5 0.4 36 5 32 300 -3.8 0 -3.5 -3.7 11/22/2005 01:50:00 1.7 0.3 2.3 1.1 1.5 0.3 2.3 0.7 1.3 0.3 1.9 0.4 43 4 43 300 -3.8 0 -3.5 -3.7 11/22/2005 02:00:00 1.8 0.3 2.6 1.1 1.7 0.4 2.3 0.4 1.2 0.4 2.3 0.4 38 7 35 300 -3.8 0 -3.7 -3.7 11/22/2005 02:10:00 1.6 0.3 2.3 0.7 1.4 0.4 2.3 0.4 1 0.4 1.9 0.4 36 6 34 300 -3.8 0 -3.7 -3.7 11/22/2005 02:20:00 1.8 0.3 2.3 1.1 1.4 0.3 1.9 0.4 0.9 0.4 2.3 0.4 24 5 26 300 -3.8 0 -3.7 -3.7 11/22/2005 02:30:00 2 0.2 2.6 1.5 1.6 0.3 2.3 0.7 1.1 0.4 1.9 0.4 22 5 18 300 -3.8 0 -3.7 -3.9 11/22/2005 02:40:00 1.7 0.4 2.6 0.4 1.3 0.4 2.3 0.4 0.8 0.3 1.5 0.4 27 7 39 300 -3.8 0 -3.7 -3.9 11/22/2005 02:50:00 1.5 0.3 2.3 0.7 1.2 0.3 1.9 0.4 0.6 0.3 1.5 0.4 25 5 22 300 -3.8 0 -3.7 -3.7 11/22/2005 03:00:00 1.6 0.2 2.3 0.7 1.3 0.3 2.3 0.4 0.8 0.4 1.5 0.4 18 6 16 300 -3.8 0 -3.5 -3.7 11/22/2005 03:10:00 1.6 0.3 2.3 0.7 1.3 0.4 1.9 0.4 0.8 0.4 1.9 0.4 18 5 20 300 -3.8 0 -3.7 -3.9 11/22/2005 03:20:00 1.6 0.4 2.3 0.7 1.2 0.4 2.3 0.4 0.8 0.4 1.9 0.4 16 6 30 300 -3.8 0 -3.7 -3.9 11/22/2005 03:30:00 2 0.2 2.3 1.1 1.9 0.3 2.6 1.1 1.5 0.3 2.3 0.7 8 5 8 300 -3.8 0 -3.5 -3.9 11/22/2005 03:40:00 2.2 0.2 2.6 1.5 1.9 0.3 2.6 1.1 1.5 0.4 2.3 0.7 16 4 14 300 -3.8 0 -3.5 -3.7 11/22/2005 03:50:00 1.8 0.5 2.6 0.4 1.5 0.5 2.6 0.4 1 0.5 2.3 0.4 14 5 18 300 -3.8 0 -3.5 -3.7 11/22/2005 04:00:00 0.5 0.2 1.1 0.4 0.4 0.1 0.7 0.4 0.4 0 0.7 0.4 5 4 2 300 -3.7 0 -3.5 -3.7 11/22/2005 04:10:00 1 0.2 1.5 0.7 0.8 0.2 1.1 0.4 0.6 0.2 1.1 0.4 3 2 3 300 -3.7 0 -3.5 -3.7 11/22/2005 04:20:00 1.1 0.3 1.5 0.4 0.9 0.3 1.5 0.4 0.5 0.2 1.1 0.4 10 4 8 300 -3.8 0 -3.7 -3.9 11/22/2005 04:30:00 1 0.3 1.9 0.4 0.7 0.3 1.5 0.4 0.4 0.2 1.1 0.4 18 3 18 300 -3.8 0 -3.7 -3.9 11/22/2005 04:40:00 1.4 0.3 1.9 0.4 1.2 0.3 1.9 0.4 0.8 0.3 1.5 0.4 11 4 14 300 -3.8 0 -3.7 -3.9 11/22/2005 04:50:00 0.7 0.4 1.9 0.4 0.6 0.4 1.5 0.4 0.4 0.1 1.1 0.4 14 9 35 300 -3.8 0 -3.7 -3.9 11/22/2005 05:00:00 0.7 0.3 1.5 0.4 0.5 0.2 1.1 0.4 0.4 0.1 0.7 0.4 31 5 27 300 -3.8 0 -3.5 -3.7 11/22/2005 05:10:00 0.8 0.4 1.5 0.4 0.6 0.3 1.5 0.4 0.6 0.3 1.1 0.4 26 2 27 300 -3.8 0 -3.5 -3.7 11/22/2005 05:20:00 1 0.5 1.9 0.4 0.8 0.4 1.5 0.4 0.8 0.4 1.5 0.4 30 9 36 300 -3.8 0 -3.7 -3.9 11/22/2005 05:30:00 0.7 0.3 1.5 0.4 0.5 0.2 1.1 0.4 1 0.3 1.5 0.4 9 8 355 300 -3.8 0 -3.7 -3.9 11/22/2005 05:40:00 0.4 0.2 1.1 0.4 0.4 0.1 0.7 0.4 1 0.3 1.9 0.4 23 6 10 300 -3.8 0 -3.7 -3.7 11/22/2005 05:50:00 0.4 0.2 1.1 0.4 0.4 0.1 1.1 0.4 0.7 0.3 1.5 0.4 339 20 326 300 -3.8 0 -3.5 -3.9 11/22/2005 06:00:00 0.8 0.6 2.6 0.4 0.7 0.6 3 0.4 0.8 0.6 2.6 0.4 280 28 264 300 -3.8 0 -3.7 -3.9 11/22/2005 06:10:00 1.5 0.6 3 0.4 1.4 0.6 2.6 0.4 1.3 0.5 2.6 0.4 262 17 249 300 -3.4 0 -3.3 -3.7 11/22/2005 06:20:00 1.8 0.3 2.6 1.1 1.7 0.3 2.6 0.7 1.6 0.4 2.3 0.7 252 11 254 300 -3.2 0 -3.3 -3.5 11/22/2005 06:30:00 1.9 0.6 3.4 0.4 1.8 0.6 3.4 0.4 1.6 0.7 3.4 0.4 256 12 255 300 -3.2 0 -3 -3.3 11/22/2005 06:40:00 2.3 0.6 4.2 1.1 2.1 0.6 4.2 1.1 2 0.6 3.8 0.4 254 14 257 300 -3.1 0 -2.8 -3.3 11/22/2005 06:50:00 2.1 0.4 3 1.1 2 0.4 3.4 1.1 1.8 0.4 3 0.7 263 9 261 300 -3.1 0 -2.8 -3.3 11/22/2005 07:00:00 2.8 0.8 4.6 1.5 2.7 0.8 4.6 1.1 2.4 0.8 4.2 1.1 260 12 256 300 -3.1 0 -2.8 -3.3 11/22/2005 07:10:00 3.3 0.5 4.6 1.9 3.3 0.5 4.6 1.9 3 0.6 4.2 1.9 264 10 256 300 -2.9 0 -2.8 -3 11/22/2005 07:20:00 3.4 0.5 4.6 2.3 3.4 0.5 4.6 2.3 3.1 0.6 4.6 1.5 262 7 259 300 -3 0 -2.8 -3.3 11/22/2005 07:30:00 3.1 0.4 4.2 1.9 3 0.4 3.8 1.5 2.5 0.5 3.8 1.5 263 7 256 300 -3.1 0 -3 -3.3 11/22/2005 07:40:00 2.7 0.4 3.4 1.5 2.6 0.4 3.4 1.5 2.2 0.5 3.4 0.7 266 6 257 300 -3.2 0 -3 -3.3 11/22/2005 07:50:00 2.7 0.5 3.8 1.5 2.6 0.5 4.2 1.5 2.2 0.4 3.4 0.7 269 9 269 300 -3.4 0 -3.3 -3.5 11/22/2005 08:00:00 2.6 0.4 3.8 1.5 2.6 0.4 3.4 1.5 2.2 0.4 3.4 1.1 285 9 261 300 -3.6 0 -3.5 -3.5 11/22/2005 08:10:00 2.8 0.4 3.8 1.9 2.7 0.4 4.2 1.5 2.3 0.4 3.4 1.1 289 7 297 300 -3.6 0 -3.5 -3.7 11/22/2005 08:20:00 2.7 0.4 3.8 1.9 2.7 0.4 3.4 1.5 2.1 0.4 3 1.1 285 6 282 300 -3.7 0 -3.5 -3.7 11/22/2005 08:30:00 2.1 0.4 3 1.1 2 0.4 3 1.1 1.8 0.4 3 1.1 290 7 288 300 -3.8 0 -3.5 -3.9 11/22/2005 08:40:00 2.6 0.4 3.8 1.5 2.6 0.5 3.4 1.5 2.2 0.4 3 0.4 290 7 286 300 -4 0 -3.7 -4.2 11/22/2005 08:50:00 2.1 0.4 3.4 1.1 2.1 0.4 3.4 1.1 1.8 0.4 2.6 1.1 283 5 276 300 -4 0 -3.9 -4.2 11/22/2005 09:00:00 1.6 0.3 3.4 1.1 1.5 0.3 3 0.7 1.2 0.3 2.3 0.7 287 6 281 300 -4.3 0.1 -3.9 -4.6 11/22/2005 09:10:00 1.5 0.3 2.3 1.1 1.4 0.3 2.3 0.7 1.1 0.3 1.9 0.7 289 7 277 300 -4.8 0 -4.6 -4.8 11/22/2005 09:20:00 1.7 0.2 2.6 1.1 1.5 0.3 2.3 0.7 1.3 0.2 1.9 0.7 284 6 280 300 -5.3 0.2 -4.8 -5.5 11/22/2005 09:30:00 1.6 0.3 2.3 1.1 1.4 0.3 2.3 0.7 1.2 0.3 1.9 0.7 279 7 267 300 -5.7 0.1 -5.5 -5.9 11/22/2005 09:40:00 1.3 0.2 1.9 0.7 1.2 0.2 1.9 0.7 1 0.2 1.5 0.7 292 3 288 300 -6 0 -5.7 -6.1 11/22/2005 09:50:00 1 0.3 1.5 0.4 0.9 0.3 1.5 0.4 0.8 0.2 1.1 0.4 299 2 302 300 -6 0 -5.9 -6.1 11/22/2005 10:00:00 0.5 0.2 1.1 0.4 0.5 0.2 1.1 0.4 0.4 0.1 1.1 0.4 294 2 297 300 -6.5 0 -6.1 -6.8 11/22/2005 10:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 293 0 300 300 -6.9 0.1 -6.6 -7 11/22/2005 10:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 293 0 300 300 -7.1 0 -7 -7.2 11/22/2005 10:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 293 0 300 300 -7.4 0.1 -7.2 -7.6 11/22/2005 10:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 293 0 300 300 -7.6 0 -7.4 -7.6 11/22/2005 10:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 293 0 300 300 -7.8 0.1 -7.6 -8.1 11/22/2005 11:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 293 0 300 300 -7.8 0 -7.4 -8.1 11/22/2005 11:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 263 41 300 300 -7.4 0 -7.2 -7.4 11/22/2005 11:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 205 0 300 300 -7.5 0 -7.2 -7.6 11/22/2005 11:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 205 0 300 300 -7.3 0 -7.2 -7.4 11/22/2005 11:40:00 0.4 0 0.7 0.4 0.4 0 0.4 0.4 0.5 0.2 1.1 0.4 205 0 205 300 -7.4 0 -7.2 -7.4 11/22/2005 11:50:00 1.2 0.5 1.9 0.4 1 0.5 1.9 0.4 1.1 0.2 1.5 0.7 115 86 36 300 -7.2 0.1 -7 -7.4 11/22/2005 12:00:00 2.2 0.4 2.6 1.1 2.1 0.4 2.6 1.1 1.7 0.4 2.3 1.1 39 4 36 300 -7.2 0 -7 -7.2 11/22/2005 12:10:00 2.6 0.2 3 2.3 2.5 0.2 3 1.9 1.7 0.3 2.3 1.1 35 8 31 300 -6.8 0.2 -6.6 -7 11/22/2005 12:20:00 2.6 0.2 3 2.3 2.6 0.2 3 1.9 1.5 0.3 2.3 1.1 38 3 34 300 -6.4 0 -6.1 -6.6 11/22/2005 12:30:00 2.6 0.3 3.4 1.9 2.6 0.3 3.4 1.9 1.5 0.2 2.3 1.1 41 1 39 300 -6.1 0.1 -5.7 -6.4 11/22/2005 12:40:00 3.3 0.2 3.8 2.6 3.2 0.2 3.8 2.3 1.8 0.3 2.6 1.1 31 5 32 300 -5.9 0 -5.7 -5.9 11/22/2005 12:50:00 3.4 0.3 4.2 2.6 3.1 0.3 3.8 1.9 1.8 0.4 3 1.1 26 4 24 300 -5.7 0 -5.5 -5.7 11/22/2005 13:00:00 3.3 0.4 4.2 2.3 2.9 0.5 3.8 1.5 1.8 0.4 3 0.7 25 6 19 300 -5.4 0.2 -5 -5.7 11/22/2005 13:10:00 3.6 0.3 4.6 2.6 3 0.5 4.2 1.9 2.1 0.5 3.8 0.7 23 5 30 300 -5.1 0 -5 -5.3 11/22/2005 13:20:00 2.8 0.5 4.2 1.5 2.4 0.5 3.8 1.1 1.6 0.5 3.4 0.4 29 8 25 300 -4.8 0 -4.6 -5 11/22/2005 13:30:00 2.4 0.5 3.8 1.5 2.2 0.5 3.8 0.7 1.5 0.4 2.6 0.4 35 8 46 300 -4.8 0 -4.6 -4.8 11/22/2005 13:40:00 2.8 0.5 3.8 1.5 2.6 0.5 3.8 1.5 1.9 0.5 3.4 0.7 40 8 37 300 -4.9 0 -4.8 -4.8 11/22/2005 13:50:00 2.3 0.4 3.4 1.1 2.2 0.5 3 1.1 1.3 0.6 2.6 0.4 47 7 48 300 -4.9 0 -4.8 -4.8 11/22/2005 14:00:00 1.4 0.3 2.3 0.4 1.3 0.3 1.9 0.4 0.6 0.3 1.5 0.4 50 5 57 300 -4.9 0 -4.8 -4.8 11/22/2005 14:10:00 1.5 0.3 2.6 0.7 1.4 0.4 2.3 0.4 0.6 0.3 1.9 0.4 43 3 41 300 -4.9 0 -4.8 -4.8 11/22/2005 14:20:00 1.6 0.4 2.3 0.7 1.5 0.4 2.3 0.7 0.9 0.4 1.9 0.4 43 6 41 300 -4.9 0 -4.8 -4.8 11/22/2005 14:30:00 1 0.3 1.9 0.4 0.9 0.3 1.9 0.4 0.7 0.3 1.5 0.4 11 6 19 300 -4.9 0 -4.8 -5 11/22/2005 14:40:00 0.9 0.4 1.5 0.4 0.8 0.4 1.5 0.4 0.6 0.3 1.5 0.4 5 4 8 300 -4.9 0 -4.8 -5 11/22/2005 14:50:00 0.8 0.3 1.5 0.4 0.8 0.2 1.5 0.4 0.8 0.3 1.5 0.4 359 1 359 300 -4.9 0 -4.8 -4.8 11/22/2005 15:00:00 0.8 0.4 1.5 0.4 0.8 0.4 1.5 0.4 0.7 0.3 1.5 0.4 357 2 0 300 -4.9 0 -4.8 -4.8 11/22/2005 15:10:00 1.2 0.4 1.9 0.7 1.1 0.4 1.9 0.4 0.9 0.3 1.5 0.4 359 3 356 300 -4.9 0 -4.8 -5 11/22/2005 15:20:00 1.7 0.3 2.3 1.1 1.6 0.3 2.3 0.7 1.4 0.3 1.9 0.4 337 13 351 300 -5 0 -5 -5 11/22/2005 15:30:00 1.6 0.3 2.3 1.1 1.5 0.3 2.3 0.7 1.5 0.3 1.9 0.4 337 9 346 300 -5 0 -5 -5 11/22/2005 15:40:00 1.7 0.3 2.3 0.7 1.7 0.3 2.3 0.7 1.4 0.2 1.9 0.7 345 0 346 300 -5.3 0 -5 -5.5 11/22/2005 15:50:00 0.4 0.1 1.1 0.4 0.4 0.1 1.1 0.4 0.6 0.3 1.5 0.4 345 0 345 300 -5.3 0 -5.3 -5.5 11/22/2005 16:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.5 0.2 1.1 0.4 345 0 300 300 -5.5 0 -5.3 -5.7 11/22/2005 16:10:00 0.6 0.3 1.5 0.4 0.5 0.2 1.1 0.4 0.8 0.4 1.5 0.4 75 53 126 300 -5.9 0 -5.7 -5.9 11/22/2005 16:20:00 1.6 0.4 2.3 0.4 1.5 0.4 2.3 0.4 1.5 0.2 2.3 0.7 159 21 183 300 -6 0 -5.7 -5.9 11/22/2005 16:30:00 1.2 0.3 1.9 0.7 0.9 0.4 1.9 0.4 1 0.3 1.5 0.4 178 4 171 300 -5.9 0 -5.7 -5.9 11/22/2005 16:40:00 0.8 0.3 1.5 0.4 0.6 0.2 1.1 0.4 0.5 0.2 1.1 0.4 176 8 181 300 -6 0 -5.9 -6.1 11/22/2005 16:50:00 0.5 0.2 1.1 0.4 0.4 0.1 1.1 0.4 0.4 0 0.7 0.4 164 8 162 300 -6.2 0 -6.1 -6.4 11/22/2005 17:00:00 0.7 0.3 1.5 0.4 0.7 0.3 1.5 0.4 0.5 0.2 1.1 0.4 204 3 201 300 -6.5 0 -6.1 -6.6 11/22/2005 17:10:00 0.8 0.4 1.9 0.4 0.5 0.3 1.5 0.4 0.4 0.2 1.1 0.4 238 10 259 300 -6.6 0 -6.6 -6.8 11/22/2005 17:20:00 1.5 0.2 1.9 0.7 1.2 0.3 1.9 0.7 1.2 0.2 1.9 0.7 268 9 264 300 -6.6 0 -6.6 -6.6 11/22/2005 17:30:00 1.6 0.2 2.3 1.1 1.4 0.2 1.9 0.7 1.3 0.2 1.9 0.7 247 7 239 300 -6.5 0 -6.6 -6.6 11/22/2005 17:40:00 1.6 0.2 2.3 1.1 1.4 0.2 1.9 0.7 1.3 0.2 1.9 0.7 257 4 256 300 -6.5 0 -6.4 -6.6 11/22/2005 17:50:00 1.8 0.2 2.3 1.1 1.6 0.2 1.9 1.1 1.7 0.2 2.3 1.1 263 5 271 300 -6.5 0 -6.4 -6.6 11/22/2005 18:00:00 1.9 0.2 2.6 1.1 1.7 0.3 2.3 0.7 1.1 0.4 1.9 0.4 267 12 272 300 -6.4 0 -6.1 -6.6 11/22/2005 18:10:00 1.5 0.2 1.9 1.1 1.3 0.3 1.9 0.7 0.9 0.3 1.5 0.4 262 8 251 300 -6.6 0 -6.6 -6.8 11/22/2005 18:20:00 1.7 0.2 2.3 1.1 1.4 0.2 1.9 0.7 1.2 0.2 1.5 0.7 264 4 268 300 -6.9 0 -6.8 -7 11/22/2005 18:30:00 1.5 0.2 2.3 1.1 1.3 0.2 1.9 0.7 1 0.3 1.5 0.4 269 7 264 300 -6.5 0.1 -6.1 -6.8 11/22/2005 18:40:00 1.5 0.4 2.3 0.4 1.3 0.4 1.9 0.4 0.7 0.3 1.5 0.4 286 10 279 300 -6.6 0 -6.1 -6.8 11/22/2005 18:50:00 0.6 0.3 1.5 0.4 0.5 0.2 1.5 0.4 0.4 0.1 0.7 0.4 290 8 280 300 -6.8 0 -6.6 -7 11/22/2005 19:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.5 0.2 1.5 0.4 4 49 300 300 -7.1 0 -6.8 -7 11/22/2005 19:10:00 0.5 0.2 1.1 0.4 0.4 0.1 1.1 0.4 0.8 0.3 1.5 0.4 67 11 60 300 -7.2 0.1 -7 -7.4 11/22/2005 19:20:00 1.2 0.5 2.3 0.4 1 0.5 1.9 0.4 1 0.4 1.9 0.4 91 9 91 300 -7.5 0 -7.2 -7.6 11/22/2005 19:30:00 1.2 0.3 1.9 0.4 1 0.4 1.5 0.4 0.8 0.3 1.5 0.4 98 7 106 300 -7.7 0 -7.4 -7.9 11/22/2005 19:40:00 1.1 0.5 1.9 0.4 1 0.4 1.9 0.4 0.7 0.3 1.5 0.4 82 8 71 300 -8 0.1 -7.6 -8.3 11/22/2005 19:50:00 0.5 0.3 1.5 0.4 0.5 0.3 1.5 0.4 0.6 0.3 1.9 0.4 86 5 88 300 -8.2 0 -8.1 -8.3 11/22/2005 20:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0.1 0.7 0.4 88 0 300 300 -7.8 0.2 -7.6 -8.1 11/22/2005 20:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0.2 1.1 0.4 88 0 300 300 -8 0.1 -7.6 -8.1 11/22/2005 20:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 88 0 300 300 -7.9 0 -7.6 -8.1 11/22/2005 20:30:00 0.4 0.1 1.1 0.4 0.4 0 0.7 0.4 0.4 0 0.7 0.4 145 51 247 300 -8 0 -7.9 -8.1 11/22/2005 20:40:00 0.6 0.3 1.5 0.4 0.4 0.2 1.1 0.4 0.4 0 0.7 0.4 247 11 259 300 -7.7 0 -7.6 -7.9 11/22/2005 20:50:00 0.4 0 0.7 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 240 6 256 300 -7.5 0 -7.2 -7.6 11/22/2005 21:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 235 6 300 300 -7.4 0 -7.2 -7.4 11/22/2005 21:10:00 0.6 0.3 1.5 0.4 0.5 0.3 1.5 0.4 0.7 0.4 1.5 0.4 209 18 221 300 -7.2 0 -7 -7.2 11/22/2005 21:20:00 1.5 0.3 2.3 0.7 1.4 0.3 2.3 0.7 1.3 0.3 2.3 0.4 232 7 233 300 -7.1 0 -7 -7 11/22/2005 21:30:00 1.1 0.4 1.9 0.4 0.9 0.4 1.9 0.4 0.6 0.3 1.9 0.4 225 7 241 300 -7.1 0 -6.8 -7 11/22/2005 21:40:00 0.6 0.3 1.5 0.4 0.6 0.3 1.5 0.4 0.6 0.3 1.5 0.4 233 19 206 300 -6.9 0 -6.8 -7 11/22/2005 21:50:00 1.4 0.8 2.6 0.4 1.3 0.8 2.6 0.4 1.1 0.7 2.6 0.4 255 5 256 300 -7 0 -6.8 -7 11/22/2005 22:00:00 0.9 0.5 1.9 0.4 0.7 0.4 1.5 0.4 0.8 0.5 1.9 0.4 264 10 254 300 -6.8 0 -6.6 -7 11/22/2005 22:10:00 0.4 0.2 1.1 0.4 0.4 0 0.7 0.4 0.4 0.1 1.1 0.4 272 17 275 300 -6.8 0 -6.6 -7 11/22/2005 22:20:00 0.5 0.3 1.5 0.4 0.4 0.2 1.5 0.4 0.4 0.2 1.1 0.4 255 6 234 300 -7.1 0 -6.8 -7 11/22/2005 22:30:00 0.6 0.4 1.5 0.4 0.5 0.3 1.5 0.4 0.5 0.3 1.5 0.4 238 5 242 300 -7 0 -6.8 -7 11/22/2005 22:40:00 1 0.4 1.9 0.4 0.8 0.4 1.5 0.4 1 0.4 1.9 0.4 231 5 239 300 -6.8 0 -6.8 -7 11/22/2005 22:50:00 0.5 0.3 1.5 0.4 0.4 0.1 1.1 0.4 0.5 0.2 1.1 0.4 235 16 247 300 -6.8 0 -6.8 -6.8 11/22/2005 23:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 214 0 300 300 -6.8 0 -6.6 -6.8 11/22/2005 23:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 214 0 300 300 -6.8 0 -6.6 -6.8 11/22/2005 23:20:00 0.6 0.3 1.1 0.4 0.4 0.2 1.1 0.4 0.5 0.2 1.1 0.4 173 35 145 300 -6.8 0 -6.6 -6.8 11/22/2005 23:30:00 0.5 0.3 1.5 0.4 0.4 0.2 1.5 0.4 0.5 0.3 1.5 0.4 170 28 193 300 -6.7 0 -6.6 -6.8 11/22/2005 23:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 194 0 300 300 -6.7 0 -6.6 -6.8 11/22/2005 23:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 193 0 300 300 -6.6 0 -6.6 -6.8 11/23/2005 00:00:00 0.4 0.1 1.1 0.4 0.4 0 0.7 0.4 0.4 0.1 0.7 0.4 191 3 191 300 -6.5 0 -6.6 -6.6 11/23/2005 00:10:00 0.4 0.1 1.1 0.4 0.4 0.2 1.1 0.4 0.6 0.3 1.1 0.4 201 11 210 300 -6.5 0 -6.6 -6.6 11/23/2005 00:20:00 0.5 0.2 1.5 0.4 0.5 0.2 1.5 0.4 0.5 0.3 1.5 0.4 205 11 210 300 -6.5 0 -6.6 -6.6 11/23/2005 00:30:00 0.4 0.2 1.1 0.4 0.4 0.2 1.1 0.4 0.4 0.2 1.5 0.4 209 9 209 300 -6.5 0 -6.6 -6.6 11/23/2005 00:40:00 1.2 0.4 1.9 0.4 1 0.4 1.9 0.4 1 0.4 1.9 0.4 231 10 231 300 -6.5 0 -6.6 -6.6 11/23/2005 00:50:00 1.2 0.5 2.6 0.4 1 0.5 2.3 0.4 1.2 0.4 2.6 0.4 235 15 242 300 -6.5 0 -6.6 -6.6 11/23/2005 01:00:00 0.6 0.5 1.9 0.4 0.6 0.4 1.9 0.4 0.7 0.4 1.9 0.4 242 19 261 300 -6.5 0 -6.6 -6.6 11/23/2005 01:10:00 0.8 0.5 1.9 0.4 0.6 0.4 1.5 0.4 0.8 0.5 1.9 0.4 265 2 263 300 -6.5 0 -6.6 -6.6 11/23/2005 01:20:00 0.4 0.1 0.7 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 269 2 267 300 -6.6 0 -6.6 -6.6 11/23/2005 01:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 270 0 300 300 -6.6 0 -6.6 -6.6 11/23/2005 01:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 270 0 300 300 -6.5 0 -6.6 -6.6 11/23/2005 01:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 270 0 300 300 -6.5 0 -6.6 -6.8 11/23/2005 02:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 270 0 300 300 -6.6 0 -6.6 -6.6 11/23/2005 02:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0.1 0.7 0.4 253 5 300 300 -6.6 0 -6.6 -6.8 11/23/2005 02:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 252 0 300 300 -6.6 0 -6.6 -6.8 11/23/2005 02:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 272 15 300 300 -6.6 0 -6.6 -6.8 11/23/2005 02:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 283 0 300 300 -6.7 0 -6.6 -6.8 11/23/2005 02:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 283 0 300 300 -6.6 0 -6.6 -6.8 11/23/2005 03:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 283 0 300 300 -6.6 0 -6.6 -6.8 11/23/2005 03:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 65 76 300 300 -6.7 0 -6.6 -6.8 11/23/2005 03:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 40 0 300 300 -6.7 0 -6.6 -6.8 11/23/2005 03:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 41 0 300 300 -6.6 0 -6.6 -6.8 11/23/2005 03:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 41 0 300 300 -6.6 0 -6.6 -6.8 11/23/2005 03:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 40 0 300 300 -6.6 0 -6.6 -6.8 11/23/2005 04:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 40 0 300 300 -6.6 0 -6.6 -6.8 11/23/2005 04:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 41 0 300 300 -6.6 0 -6.6 -6.8 11/23/2005 04:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 41 0 300 300 -6.6 0 -6.6 -6.6 11/23/2005 04:30:00 0.8 0.5 1.9 0.4 0.7 0.4 1.5 0.4 0.7 0.4 1.5 0.4 42 3 49 300 -6.5 0 -6.6 -6.6 11/23/2005 04:40:00 1.3 0.4 1.9 0.4 1.1 0.4 1.9 0.4 1.1 0.4 1.9 0.4 60 6 52 300 -6.5 0 -6.6 -6.6 11/23/2005 04:50:00 0.7 0.3 1.5 0.4 0.5 0.3 1.5 0.4 0.6 0.3 1.5 0.4 74 3 67 300 -6.5 0 -6.6 -6.6 11/23/2005 05:00:00 0.4 0.1 0.7 0.4 0.4 0 0.4 0.4 0.4 0 0.7 0.4 75 0 75 300 -6.5 0 -6.6 -6.6 11/23/2005 05:10:00 0.4 0.2 1.1 0.4 0.4 0.1 0.7 0.4 0.4 0.1 0.7 0.4 75 0 75 300 -6.5 0 -6.6 -6.6 11/23/2005 05:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 75 0 300 300 -6.5 0 -6.6 -6.6 11/23/2005 05:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 75 0 300 300 -6.5 0 -6.6 -6.6 11/23/2005 05:40:00 0.5 0.2 1.1 0.4 0.4 0.1 0.7 0.4 0.4 0.1 0.7 0.4 63 10 60 300 -6.5 0 -6.4 -6.6 11/23/2005 05:50:00 0.8 0.3 1.5 0.4 0.5 0.2 1.1 0.4 0.5 0.2 1.1 0.4 45 7 36 300 -6.5 0 -6.6 -6.6 11/23/2005 06:00:00 0.7 0.4 1.5 0.4 0.5 0.3 1.1 0.4 0.5 0.2 1.1 0.4 44 4 44 300 -6.5 0 -6.4 -6.6 11/23/2005 06:10:00 0.4 0.1 1.1 0.4 0.4 0 0.7 0.4 0.4 0 0.4 0.4 49 5 52 300 -6.5 0 -6.4 -6.6 11/23/2005 06:20:00 0.6 0.3 1.1 0.4 0.5 0.2 1.1 0.4 0.4 0.1 1.1 0.4 59 6 57 300 -6.5 0 -6.4 -6.6 11/23/2005 06:30:00 0.9 0.2 1.5 0.4 0.6 0.2 1.1 0.4 0.5 0.2 1.1 0.4 62 0 62 300 -6.5 0 -6.4 -6.6 11/23/2005 06:40:00 0.5 0.3 1.5 0.4 0.4 0.2 1.1 0.4 0.4 0.1 1.1 0.4 53 4 62 300 -6.4 0 -6.4 -6.6 11/23/2005 06:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 51 0 300 300 -6.4 0 -6.4 -6.6 11/23/2005 07:00:00 0.4 0.1 1.1 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 54 10 80 300 -6.4 0 -6.1 -6.6 11/23/2005 07:10:00 0.5 0.3 1.1 0.4 0.4 0.1 1.1 0.4 0.4 0 0.7 0.4 90 0 90 300 -6.4 0 -6.1 -6.6 11/23/2005 07:20:00 0.4 0 0.7 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 90 0 90 300 -6.4 0 -6.1 -6.4 11/23/2005 07:30:00 0.8 0.3 1.5 0.4 0.5 0.2 1.1 0.4 0.7 0.3 1.1 0.4 68 13 60 300 -6.3 0 -6.1 -6.4 11/23/2005 07:40:00 0.8 0.4 1.9 0.4 0.7 0.4 1.5 0.4 0.6 0.2 1.1 0.4 56 7 41 300 -6.2 0 -6.1 -6.4 11/23/2005 07:50:00 1.7 0.2 2.3 1.1 1.6 0.3 2.3 0.7 1.2 0.4 1.9 0.4 45 5 45 300 -6.2 0 -6.1 -6.4 11/23/2005 08:00:00 1.3 0.2 1.9 0.7 1.1 0.3 1.5 0.4 0.8 0.4 1.5 0.4 43 5 44 300 -6.2 0 -6.1 -6.1 11/23/2005 08:10:00 1.2 0.2 1.9 0.7 1 0.3 1.9 0.4 0.8 0.4 1.9 0.4 51 6 42 300 -6.1 0 -6.1 -6.1 11/23/2005 08:20:00 1.4 0.5 2.6 0.4 1.2 0.5 2.3 0.4 0.9 0.5 2.3 0.4 60 9 53 300 -6.1 0 -6.1 -6.1 11/23/2005 08:30:00 0.5 0.2 1.5 0.4 0.4 0.1 1.1 0.4 0.4 0.1 1.1 0.4 61 6 66 300 -6.1 0 -5.9 -6.1 11/23/2005 08:40:00 0.7 0.4 1.5 0.4 0.5 0.3 1.1 0.4 0.5 0.2 1.1 0.4 66 3 67 300 -6.1 0 -5.9 -6.1 11/23/2005 08:50:00 1.2 0.2 1.5 0.7 1 0.2 1.5 0.4 1.1 0.2 1.5 0.4 54 2 54 300 -6.1 0 -5.9 -6.1 11/23/2005 09:00:00 1.6 0.2 1.9 1.1 1.4 0.2 2.3 0.7 1.2 0.4 1.9 0.4 51 6 54 300 -6 0 -5.9 -6.1 11/23/2005 09:10:00 2 0.4 3 1.1 1.8 0.4 2.6 0.7 1.3 0.4 2.6 0.4 44 6 42 300 -6 0 -5.9 -6.1 11/23/2005 09:20:00 1.9 0.4 3 0.7 1.8 0.5 3 0.4 1.2 0.5 2.6 0.4 49 9 51 300 -6 0 -5.9 -5.9 11/23/2005 09:30:00 1.9 0.5 3 0.4 1.7 0.6 3 0.4 1.1 0.5 2.3 0.4 47 13 39 300 -6 0 -5.9 -5.9 11/23/2005 09:40:00 1.7 0.5 3 0.4 1.5 0.6 3 0.4 0.8 0.5 1.9 0.4 51 12 51 300 -5.9 0 -5.7 -5.9 11/23/2005 09:50:00 1.9 0.4 2.6 0.7 1.9 0.4 2.6 0.4 1.2 0.5 2.3 0.4 55 8 54 300 -5.8 0 -5.7 -5.9 11/23/2005 10:00:00 1.7 0.9 3.4 0.4 1.6 0.8 3 0.4 1.1 0.5 2.6 0.4 56 19 37 300 -5.7 0 -5.7 -5.7 11/23/2005 10:10:00 1.7 0.7 3 0.4 1.7 0.7 3 0.4 1.4 0.6 3 0.4 65 17 61 300 -5.6 0 -5.5 -5.7 11/23/2005 10:20:00 2 0.5 3 0.7 1.9 0.6 3 0.4 1.4 0.6 3 0.4 61 14 78 300 -5.6 0 -5.5 -5.7 11/23/2005 10:30:00 1.8 0.8 3.4 0.4 1.8 0.8 3.4 0.4 1.6 0.6 3.4 0.4 60 16 63 300 -5.5 0 -5.5 -5.7 11/23/2005 10:40:00 1.8 0.6 3.4 0.4 1.7 0.6 3 0.4 1.4 0.6 2.6 0.4 52 17 43 300 -5.4 0 -5.5 -5.5 11/23/2005 10:50:00 2.4 0.8 4.2 0.4 2.4 0.9 4.6 0.4 1.9 0.8 3.8 0.4 53 12 52 300 -5.4 0 -5.5 -5.5 11/23/2005 11:00:00 2 0.8 3.8 0.4 1.9 0.8 3.8 0.4 1.6 0.8 3.4 0.4 54 16 53 300 -5.4 0 -5.3 -5.5 11/23/2005 11:10:00 2.4 1 4.6 0.4 2.3 1 4.2 0.4 1.7 1 4.2 0.4 56 15 56 300 -5.4 0 -5.3 -5.5 11/23/2005 11:20:00 2.3 0.6 3.8 0.7 2.1 0.7 3.8 0.4 1.4 0.6 2.6 0.4 49 17 45 300 -5.3 0 -5 -5.5 11/23/2005 11:30:00 3.2 0.8 5.3 0.7 3.2 0.9 5.3 0.7 2.3 0.8 4.6 0.7 54 15 54 300 -5.2 0 -5 -5.3 11/23/2005 11:40:00 3.7 0.8 5.3 1.5 3.7 0.8 5.3 1.5 2.6 1 4.6 0.4 54 17 41 300 -5 0 -5 -5 11/23/2005 11:50:00 3.7 1 6.8 1.5 3.6 1 6.8 1.5 2.5 0.9 4.6 0.7 54 21 39 300 -4.9 0 -4.8 -5 11/23/2005 12:00:00 3.6 0.6 5.3 1.9 3.5 0.7 5.7 1.5 2.6 0.7 4.2 0.4 43 13 34 300 -4.8 0 -4.6 -5 11/23/2005 12:10:00 3.2 0.6 4.6 1.9 3 0.8 4.6 1.1 2.3 0.7 3.8 0.4 39 13 51 300 -4.7 0 -4.6 -4.8 11/23/2005 12:20:00 2.5 0.7 3.8 0.4 2.3 0.7 3.8 0.4 1.7 0.6 3 0.4 33 12 36 300 -4.5 0 -4.4 -4.6 11/23/2005 12:30:00 2.4 0.7 4.2 0.4 2.2 0.7 3.8 0.4 1.6 0.7 3.4 0.4 43 15 40 300 -4.3 0 -4.4 -4.4 11/23/2005 12:40:00 2.5 0.6 3.8 1.1 2.5 0.6 3.8 0.7 1.8 0.6 3.4 0.4 48 14 49 300 -4.3 0 -4.4 -4.4 11/23/2005 12:50:00 1.6 0.8 3.4 0.4 1.6 0.7 3.4 0.4 1.2 0.7 3 0.4 68 22 53 300 -4.3 0 -4.2 -4.4 11/23/2005 13:00:00 2 0.6 3 0.4 1.9 0.6 3 0.4 1.6 0.6 3 0.4 67 14 80 300 -4.3 0 -4.2 -4.4 11/23/2005 13:10:00 1.7 0.5 3 0.4 1.6 0.5 3 0.4 1.3 0.5 2.6 0.4 76 13 87 300 -4.2 0 -3.9 -4.4 11/23/2005 13:20:00 1.3 0.5 2.6 0.4 1.2 0.5 2.3 0.4 1.1 0.4 2.3 0.4 71 13 72 300 -3.9 0 -3.7 -4.2 11/23/2005 13:30:00 1.7 0.6 3.4 0.4 1.7 0.6 3.4 0.4 1.5 0.6 3 0.4 69 13 79 300 -3.8 0 -3.7 -3.7 11/23/2005 13:40:00 1.7 0.5 2.6 0.4 1.7 0.5 3 0.4 1.5 0.5 2.6 0.4 76 15 73 300 -3.8 0 -3.7 -3.9 11/23/2005 13:50:00 1.2 0.6 2.6 0.4 1.3 0.7 3 0.4 1.2 0.5 2.6 0.4 65 15 44 300 -3.8 0 -3.7 -3.9 11/23/2005 14:00:00 1.4 0.7 3 0.4 1.5 0.7 3 0.4 1.3 0.7 2.6 0.4 59 14 69 300 -3.9 0 -3.7 -3.9 11/23/2005 14:10:00 1.6 0.5 2.6 0.4 1.7 0.5 2.6 0.4 1.5 0.5 2.6 0.4 59 13 63 300 -4 0 -3.9 -3.9 11/23/2005 14:20:00 1.5 0.6 2.6 0.4 1.4 0.6 3 0.4 1.4 0.5 2.6 0.4 63 14 57 300 -4 0 -3.9 -3.9 11/23/2005 14:30:00 1.5 0.6 3 0.4 1.4 0.6 3 0.4 0.9 0.6 2.3 0.4 55 12 59 300 -4 0 -3.9 -3.9 11/23/2005 14:40:00 1 0.5 2.3 0.4 1 0.5 2.3 0.4 0.7 0.4 1.9 0.4 36 15 48 300 -3.9 0 -3.9 -3.9 11/23/2005 14:50:00 0.5 0.3 1.1 0.4 0.5 0.2 1.1 0.4 0.6 0.3 1.5 0.4 67 11 47 300 -4 0 -3.9 -4.2 11/23/2005 15:00:00 0.4 0.2 1.1 0.4 0.4 0.2 1.1 0.4 0.6 0.3 1.5 0.4 297 86 227 300 -3.9 0 -3.7 -4.2 11/23/2005 15:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0.1 0.7 0.4 316 53 300 300 -4.2 0 -3.9 -4.4 11/23/2005 15:20:00 1.3 0.8 3 0.4 1.3 0.8 3 0.4 1.3 0.7 2.6 0.4 308 17 300 300 -4.3 0 -4.2 -4.6 11/23/2005 15:30:00 3.2 0.4 3.8 2.3 3.2 0.4 3.8 1.9 2.8 0.4 3.8 1.5 277 8 274 300 -4.5 0 -4.4 -4.6 11/23/2005 15:40:00 3.3 0.4 4.2 1.9 3.3 0.5 4.2 1.9 2.6 0.6 3.8 0.7 261 8 260 300 -4.6 0.1 -4.4 -5 11/23/2005 15:50:00 3.4 0.5 4.6 2.3 3.3 0.5 4.6 2.3 2.8 0.4 3.8 1.5 245 6 246 300 -4.9 0 -4.8 -5 11/23/2005 16:00:00 3.4 0.7 4.9 1.1 3.4 0.7 4.9 1.1 2.6 0.7 4.2 0.7 244 11 245 300 -4.7 0.1 -4.4 -4.8 11/23/2005 16:10:00 2.7 0.6 4.9 1.5 2.6 0.6 4.6 1.5 2 0.7 4.2 0.4 248 13 268 300 -4.4 0 -4.4 -4.6 11/23/2005 16:20:00 3 0.5 4.6 1.9 3 0.5 4.2 1.9 2.6 0.6 4.2 1.1 251 9 241 300 -4.3 0 -4.4 -4.4 11/23/2005 16:30:00 3.5 0.8 5.7 1.1 3.5 0.8 5.7 1.1 3 0.8 4.9 1.1 253 10 264 300 -4.4 0 -4.4 -4.6 11/23/2005 16:40:00 4.4 0.8 6.5 2.6 4.4 0.9 6.5 3 4.2 0.9 6.8 2.3 266 7 268 300 -4.4 0 -4.4 -4.6 11/23/2005 16:50:00 4.8 0.7 6.8 3 4.8 0.7 6.5 3.4 4.4 0.8 6.1 2.3 265 10 260 300 -4.6 0.1 -4.4 -4.8 11/23/2005 17:00:00 3.8 0.6 5.3 1.9 3.7 0.6 5.3 2.3 3.2 0.7 4.9 1.5 253 11 273 300 -4.9 0 -4.6 -5 11/23/2005 17:10:00 2.9 0.6 4.6 1.5 2.9 0.6 4.9 1.5 2.7 0.6 4.6 1.1 263 10 255 300 -5 0 -4.8 -5 11/23/2005 17:20:00 3.5 0.9 6.5 1.5 3.4 0.9 6.5 1.5 3.1 0.8 6.8 1.1 266 10 263 300 -5 0 -5 -5 11/23/2005 17:30:00 3.9 0.8 6.1 1.9 3.9 0.8 6.1 1.9 3.5 0.9 5.7 1.5 259 11 267 300 -5.2 0 -5 -5.3 11/23/2005 17:40:00 3.7 0.6 5.7 2.3 3.6 0.7 5.3 1.9 3.3 0.7 4.9 1.1 254 10 270 300 -5.3 0 -5 -5.5 11/23/2005 17:50:00 2.9 0.7 4.6 1.1 2.7 0.7 4.6 1.1 2.4 0.7 4.2 0.4 251 12 247 300 -5.4 0 -5.5 -5.5 11/23/2005 18:00:00 2.7 0.6 4.6 1.1 2.6 0.6 4.6 1.1 2.3 0.7 4.6 0.4 251 14 256 300 -5.5 0 -5.5 -5.7 11/23/2005 18:10:00 2.8 0.6 4.2 0.7 2.7 0.6 4.2 0.7 2.5 0.6 4.2 0.7 253 11 259 300 -5.6 0 -5.5 -5.7 11/23/2005 18:20:00 2.7 0.6 4.2 1.1 2.6 0.6 4.2 1.1 2.2 0.6 3.8 0.4 251 11 249 300 -5.6 0 -5.5 -5.7 11/23/2005 18:30:00 2.8 0.4 3.8 1.5 2.7 0.5 3.8 1.5 2.5 0.5 3.8 0.7 259 11 267 300 -5.6 0 -5.5 -5.7 11/23/2005 18:40:00 2.8 0.5 3.8 1.5 2.7 0.5 3.8 1.5 2.5 0.5 3.8 1.1 262 9 256 300 -5.7 0 -5.5 -5.7 11/23/2005 18:50:00 3.1 0.5 4.6 1.9 3 0.6 4.6 1.9 2.8 0.5 4.2 1.5 266 9 271 300 -5.7 0 -5.5 -5.7 11/23/2005 19:00:00 2.5 0.5 3.8 1.5 2.4 0.5 3.8 1.1 2.2 0.5 3.8 1.1 270 9 282 300 -5.7 0 -5.5 -5.7 11/23/2005 19:10:00 2.3 0.5 3.8 1.1 2.2 0.5 3.8 1.1 2.1 0.5 3.8 1.1 278 12 274 300 -5.7 0 -5.5 -5.7 11/23/2005 19:20:00 1.5 0.5 3 0.7 1.3 0.6 2.6 0.4 0.9 0.5 2.6 0.4 298 9 293 300 -5.7 0 -5.7 -5.7 11/23/2005 19:30:00 1.5 0.3 2.3 0.7 1.3 0.4 2.3 0.7 1 0.4 2.3 0.4 298 6 288 300 -5.7 0 -5.7 -5.7 11/23/2005 19:40:00 1.1 0.3 1.9 0.4 0.9 0.4 1.9 0.4 0.6 0.3 1.5 0.4 307 7 302 300 -5.8 0 -5.7 -5.9 11/23/2005 19:50:00 1 0.5 2.3 0.4 0.9 0.5 1.9 0.4 0.6 0.3 1.5 0.4 308 9 296 300 -5.9 0 -5.7 -5.9 11/23/2005 20:00:00 0.8 0.4 1.5 0.4 0.6 0.3 1.5 0.4 0.5 0.2 1.1 0.4 284 15 291 300 -5.8 0 -5.7 -5.9 11/23/2005 20:10:00 0.4 0 0.4 0.4 0.4 0 0.7 0.4 0.4 0 0.4 0.4 239 15 300 300 -5.9 0 -5.7 -5.9 11/23/2005 20:20:00 0.4 0.1 0.7 0.4 0.4 0 0.7 0.4 0.4 0.1 0.7 0.4 204 15 193 300 -6 0 -5.7 -5.9 11/23/2005 20:30:00 0.5 0.3 1.5 0.4 0.4 0.2 1.1 0.4 0.4 0.1 0.7 0.4 180 9 172 300 -6 0 -5.9 -6.1 11/23/2005 20:40:00 0.7 0.3 1.5 0.4 0.5 0.2 1.1 0.4 0.5 0.2 1.1 0.4 177 2 178 300 -6.1 0 -5.9 -6.1 11/23/2005 20:50:00 0.9 0.3 1.5 0.4 0.7 0.2 1.1 0.4 0.6 0.2 1.1 0.4 181 5 179 300 -6.2 0 -6.1 -6.4 11/23/2005 21:00:00 0.9 0.5 1.9 0.4 0.7 0.4 1.5 0.4 0.5 0.2 1.1 0.4 223 12 234 300 -6.5 0 -6.1 -6.6 11/23/2005 21:10:00 0.7 0.3 1.5 0.4 0.4 0.2 1.1 0.4 0.4 0.2 1.1 0.4 233 7 234 300 -6.7 0 -6.6 -6.8 11/23/2005 21:20:00 1.3 0.4 2.3 0.4 1 0.4 1.9 0.4 0.8 0.4 1.5 0.4 228 7 234 300 -6.9 0 -6.8 -7 11/23/2005 21:30:00 1.7 0.3 2.3 1.1 1.4 0.3 2.3 0.7 1.3 0.3 1.9 0.4 244 4 239 300 -6.9 0 -6.8 -7 11/23/2005 21:40:00 2 0.4 2.6 1.1 1.7 0.4 2.6 0.7 1.6 0.4 2.3 0.7 246 5 246 300 -7.1 0 -6.8 -7 11/23/2005 21:50:00 2.1 0.3 2.6 1.5 1.9 0.3 2.6 1.1 1.6 0.3 2.6 0.7 244 4 250 300 -7.1 0 -7 -7.2 11/23/2005 22:00:00 2.3 0.3 3 1.5 2 0.3 2.6 1.5 1.7 0.4 2.6 0.7 247 5 247 300 -7.2 0 -7 -7.2 11/23/2005 22:10:00 2.6 0.3 3.4 1.9 2.4 0.3 3 1.9 2 0.4 3 0.7 245 5 247 300 -7.3 0 -7.2 -7.4 11/23/2005 22:20:00 2.5 0.3 3.4 1.5 2.3 0.3 3 1.1 1.8 0.5 3 0.4 242 6 248 300 -7.3 0 -7.2 -7.2 11/23/2005 22:30:00 1.8 0.5 2.6 0.7 1.5 0.5 2.6 0.4 1 0.5 2.3 0.4 243 6 246 300 -7.4 0.1 -7.2 -7.6 11/23/2005 22:40:00 1.4 0.5 2.3 0.4 1.1 0.5 1.9 0.4 0.7 0.4 1.5 0.4 233 6 232 300 -7.7 0 -7.4 -7.9 11/23/2005 22:50:00 1.9 0.3 2.6 1.1 1.6 0.3 2.3 0.7 1.1 0.4 1.9 0.4 239 7 234 300 -7.7 0 -7.6 -7.9 11/23/2005 23:00:00 0.9 0.4 1.9 0.4 0.7 0.3 1.5 0.4 0.4 0.1 1.1 0.4 248 14 251 300 -8 0.1 -7.6 -8.1 11/23/2005 23:10:00 0.8 0.2 1.5 0.4 0.5 0.2 1.1 0.4 0.7 0.3 1.1 0.4 320 17 321 300 -8.2 0 -8.1 -8.3 11/23/2005 23:20:00 0.9 0.3 1.5 0.4 0.6 0.2 1.1 0.4 0.7 0.3 1.5 0.4 335 9 339 300 -8.2 0 -8.1 -8.3 11/23/2005 23:30:00 1.2 0.2 1.9 0.7 0.9 0.3 1.5 0.4 1 0.3 1.5 0.4 323 15 305 300 -8.3 0 -8.1 -8.5 11/23/2005 23:40:00 1.3 0.2 1.5 0.7 1 0.2 1.5 0.7 0.8 0.2 1.5 0.4 317 2 317 300 -8.7 0 -8.5 -8.9 11/23/2005 23:50:00 1.5 0.2 1.9 0.7 1.3 0.2 1.9 0.7 1.2 0.2 1.9 0.7 317 5 318 300 -9.4 0.2 -8.9 -9.7 11/24/2005 00:00:00 1.8 0.3 2.6 1.1 1.7 0.3 2.6 1.1 1.6 0.3 2.6 0.7 321 8 329 300 -9.5 0 -9.3 -9.7 11/24/2005 00:10:00 1.8 0.3 2.6 1.1 1.6 0.3 2.3 0.7 1.4 0.3 2.3 0.4 301 10 267 300 -9.6 0.1 -9.3 -9.7 11/24/2005 00:20:00 1.8 0.3 2.6 1.1 1.6 0.3 2.6 1.1 1.4 0.4 2.3 0.4 287 8 276 300 -9.8 0.2 -9.3 -10.2 11/24/2005 00:30:00 1.5 0.3 1.9 0.7 1.3 0.3 1.9 0.4 1 0.4 1.5 0.4 292 5 281 300 -10.2 0.1 -9.7 -10.6 11/24/2005 00:40:00 1.5 0.3 2.3 0.7 1.3 0.4 2.3 0.4 0.8 0.4 1.5 0.4 290 7 296 300 -10.6 0.1 -10.4 -11 11/24/2005 00:50:00 1.3 0.6 2.6 0.4 1.1 0.6 2.6 0.4 0.7 0.5 2.3 0.4 294 11 310 300 -10.1 0.1 -9.7 -10.4 11/24/2005 01:00:00 2.3 0.4 3.4 0.7 2.2 0.4 3 0.7 1.5 0.5 2.6 0.4 304 7 314 300 -9.8 0 -9.5 -10.2 11/24/2005 01:10:00 2.1 0.3 2.6 1.5 2 0.3 2.6 1.1 1.4 0.4 2.3 0.4 306 7 300 300 -9.4 0.1 -9.3 -9.7 11/24/2005 01:20:00 1.3 0.4 2.3 0.4 1.1 0.4 2.3 0.4 1 0.3 1.9 0.4 298 8 299 300 -9.3 0 -9.1 -9.3 11/24/2005 01:30:00 1.3 0.3 1.9 0.4 1.1 0.3 1.9 0.4 0.7 0.4 1.9 0.4 306 7 306 300 -9.5 0.2 -9.1 -9.7 11/24/2005 01:40:00 0.6 0.4 1.9 0.4 0.5 0.2 1.5 0.4 0.4 0 0.7 0.4 298 7 280 300 -10.2 0.2 -9.7 -10.6 11/24/2005 01:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 295 0 300 300 -10.7 0 -10.4 -11 11/24/2005 02:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0.1 0.7 0.4 295 0 300 300 -10.7 0.2 -10.4 -11 11/24/2005 02:10:00 0.5 0.2 1.1 0.4 0.4 0.1 0.7 0.4 0.9 0.4 1.5 0.4 4 36 36 300 -10.9 0 -10.8 -11.2 11/24/2005 02:20:00 1.3 0.3 1.9 0.7 1.1 0.3 1.5 0.4 1.1 0.4 1.9 0.4 38 3 36 300 -10.9 0.1 -10.6 -11.2 11/24/2005 02:30:00 2 0.5 2.6 1.1 1.9 0.5 2.6 1.1 1.5 0.5 2.3 0.4 41 4 45 300 -10.5 0 -10.4 -10.6 11/24/2005 02:40:00 2 0.2 2.6 1.5 1.9 0.2 2.6 1.5 1.5 0.2 1.9 1.1 47 3 41 300 -10.5 0.1 -10.4 -10.8 11/24/2005 02:50:00 2.3 0.2 2.6 1.9 2.2 0.2 2.6 1.5 1.7 0.2 2.3 1.1 52 3 47 300 -10.5 0 -10.4 -10.6 11/24/2005 03:00:00 1.9 0.4 2.6 0.7 1.8 0.4 2.6 0.7 1.4 0.3 1.9 0.4 55 6 54 300 -10.8 0 -10.6 -11 11/24/2005 03:10:00 1.6 0.2 2.3 1.1 1.4 0.2 1.9 0.7 1.3 0.2 1.9 0.4 59 4 59 300 -10.8 0 -10.6 -11 11/24/2005 03:20:00 1.3 0.2 1.9 0.7 1.1 0.3 1.5 0.7 1 0.2 1.5 0.7 55 1 54 300 -10.7 0 -10.6 -11 11/24/2005 03:30:00 1.3 0.2 1.9 0.7 1.1 0.2 1.5 0.7 0.9 0.3 1.5 0.4 47 5 43 300 -10.8 0.1 -10.6 -11.4 11/24/2005 03:40:00 1.6 0.2 1.9 1.1 1.3 0.3 1.9 0.7 0.9 0.3 1.5 0.4 33 10 43 300 -11.5 0 -11.2 -11.6 11/24/2005 03:50:00 1.9 0.2 2.3 1.5 1.6 0.2 1.9 1.1 1.4 0.3 1.9 0.7 27 2 21 300 -11.3 0.3 -10.8 -11.6 11/24/2005 04:00:00 1.6 0.2 1.9 1.1 1.4 0.2 1.9 1.1 1.4 0.3 2.3 0.4 28 0 29 300 -10.6 0 -10.6 -10.8 11/24/2005 04:10:00 1.6 0.2 1.9 1.1 1.5 0.2 1.9 1.1 1.2 0.4 1.9 0.4 34 4 29 300 -10.5 0 -10.4 -10.6 11/24/2005 04:20:00 1.6 0.2 1.9 1.1 1.2 0.3 1.9 0.7 1.4 0.4 2.3 0.4 20 5 30 300 -10.4 0 -10.2 -10.6 11/24/2005 04:30:00 1.5 0.3 2.3 0.7 1.3 0.3 1.9 0.7 1.6 0.3 2.3 0.7 1 6 11 300 -10.3 0 -10.2 -10.4 11/24/2005 04:40:00 2 0.2 2.6 1.5 1.9 0.2 2.6 1.1 2 0.2 2.6 1.1 352 5 357 300 -10.3 0 -10.2 -10.4 11/24/2005 04:50:00 2.2 0.3 2.6 1.5 2.2 0.3 2.6 1.5 2.2 0.3 3 1.5 342 4 343 300 -10.3 0 -10.2 -10.4 11/24/2005 05:00:00 2.1 0.3 3 1.5 2 0.3 2.6 1.1 1.7 0.5 2.6 0.7 332 6 334 300 -10.3 0 -10.2 -10.4 11/24/2005 05:10:00 1.8 0.4 2.6 0.7 1.6 0.4 2.6 0.7 0.7 0.4 1.9 0.4 339 6 338 300 -10.6 0.1 -10.2 -10.8 11/24/2005 05:20:00 0.8 0.5 1.9 0.4 0.7 0.5 1.9 0.4 0.7 0.5 1.9 0.4 247 64 338 300 -10.8 0 -10.6 -11 11/24/2005 05:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.5 0.2 1.1 0.4 216 29 300 300 -11 0 -11 -11 11/24/2005 05:40:00 0.5 0.2 1.1 0.4 0.4 0.1 1.1 0.4 0.4 0.2 1.1 0.4 160 5 151 300 -11.1 0 -11 -11.2 11/24/2005 05:50:00 1.2 0.3 1.9 0.4 0.9 0.3 1.5 0.4 0.4 0.2 1.1 0.4 171 13 169 300 -11.2 0 -11 -11.4 11/24/2005 06:00:00 0.6 0.3 1.5 0.4 0.5 0.2 1.1 0.4 0.4 0 0.4 0.4 181 11 173 300 -11.2 0 -11 -11.2 11/24/2005 06:10:00 0.9 0.3 1.5 0.4 0.7 0.3 1.1 0.4 0.4 0 0.4 0.4 172 0 172 300 -11.1 0 -11 -11.2 11/24/2005 06:20:00 0.4 0 0.7 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 172 0 172 300 -11 0 -11 -11.2 11/24/2005 06:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 177 4 300 300 -11 0 -11 -11.2 11/24/2005 06:40:00 0.4 0.2 1.1 0.4 0.4 0.1 0.7 0.4 0.5 0.2 1.1 0.4 253 58 333 300 -10.8 0 -10.6 -11 11/24/2005 06:50:00 0.9 0.3 1.5 0.4 0.6 0.2 1.1 0.4 0.6 0.3 1.1 0.4 298 5 305 300 -10.4 0.1 -10.2 -10.6 11/24/2005 07:00:00 0.9 0.2 1.5 0.4 0.6 0.2 1.1 0.4 0.5 0.2 1.1 0.4 292 3 295 300 -10.3 0 -10.2 -10.4 11/24/2005 07:10:00 1.1 0.4 1.9 0.4 0.8 0.4 1.5 0.4 0.6 0.3 1.1 0.4 284 9 270 300 -10.2 0 -10.2 -10.4 11/24/2005 07:20:00 1.2 0.3 1.9 0.7 1 0.3 1.5 0.4 0.4 0.2 1.1 0.4 276 8 280 300 -10 0 -9.7 -10.2 11/24/2005 07:30:00 0.8 0.3 1.9 0.4 0.5 0.2 1.1 0.4 0.5 0.2 1.1 0.4 272 7 266 300 -9.8 0 -9.7 -10 11/24/2005 07:40:00 0.4 0.1 1.1 0.4 0.4 0 0.4 0.4 0.4 0.1 1.1 0.4 263 9 269 300 -9.7 0 -9.7 -9.7 11/24/2005 07:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 269 0 300 300 -9.7 0 -9.7 -9.7 11/24/2005 08:00:00 0.5 0.3 1.5 0.4 0.5 0.3 1.5 0.4 0.4 0.2 1.5 0.4 248 23 212 300 -9.8 0 -9.7 -10 11/24/2005 08:10:00 0.7 0.3 1.5 0.4 0.8 0.3 1.5 0.4 0.7 0.3 1.5 0.4 205 5 205 300 -9.7 0 -9.7 -10 11/24/2005 08:20:00 0.4 0.1 0.7 0.4 0.4 0.1 0.7 0.4 0.4 0.1 1.1 0.4 193 6 198 300 -9.7 0 -9.7 -9.7 11/24/2005 08:30:00 0.6 0.3 1.5 0.4 0.4 0.2 1.1 0.4 0.4 0.1 1.1 0.4 176 12 181 300 -9.8 0 -9.7 -10 11/24/2005 08:40:00 0.5 0.2 1.1 0.4 0.4 0.1 0.7 0.4 0.4 0.2 1.1 0.4 192 5 193 300 -10.1 0.1 -9.7 -10.2 11/24/2005 08:50:00 0.4 0 0.7 0.4 0.4 0 0.7 0.4 0.4 0.1 0.7 0.4 214 3 215 300 -10.4 0 -10.2 -10.4 11/24/2005 09:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 224 12 300 300 -10.4 0 -10.4 -10.4 11/24/2005 09:10:00 0.7 0.3 1.1 0.4 0.5 0.2 1.1 0.4 0.4 0.1 0.7 0.4 255 5 256 300 -10.4 0 -10.4 -10.6 11/24/2005 09:20:00 1.2 0.5 2.6 0.4 0.9 0.5 2.3 0.4 0.6 0.4 1.9 0.4 276 13 280 300 -10.4 0 -10.4 -10.6 11/24/2005 09:30:00 2 0.2 2.6 1.5 1.9 0.3 2.6 1.1 1.6 0.3 2.3 0.7 308 8 297 300 -10.4 0 -10.4 -10.4 11/24/2005 09:40:00 2.1 0.2 3 1.5 1.9 0.3 2.6 1.1 1.7 0.3 2.3 0.7 314 7 318 300 -10.3 0 -10.2 -10.4 11/24/2005 09:50:00 1.8 0.3 2.3 1.1 1.6 0.3 2.3 0.7 1.5 0.3 2.3 0.7 320 5 320 300 -10.1 0 -10.2 -10.2 11/24/2005 10:00:00 0.9 0.5 1.9 0.4 0.9 0.4 1.9 0.4 0.6 0.4 1.5 0.4 334 7 318 300 -10.1 0 -10 -10.2 11/24/2005 10:10:00 0.4 0 0.7 0.4 0.4 0 0.4 0.4 0.4 0.1 0.7 0.4 150 90 187 300 -10 0 -9.7 -10.2 11/24/2005 10:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 203 3 300 300 -9.8 0 -9.7 -10.2 11/24/2005 10:30:00 0.6 0.3 1.5 0.4 0.5 0.2 1.1 0.4 0.4 0.1 1.1 0.4 234 15 237 300 -9.8 0 -9.7 -9.7 11/24/2005 10:40:00 0.8 0.4 1.5 0.4 0.6 0.3 1.5 0.4 0.6 0.3 1.1 0.4 254 14 239 300 -9.8 0 -9.7 -9.7 11/24/2005 10:50:00 0.5 0.3 1.5 0.4 0.4 0.2 1.1 0.4 0.5 0.2 1.1 0.4 296 8 318 300 -9.8 0 -9.7 -9.7 11/24/2005 11:00:00 0.4 0 0.7 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 305 6 301 300 -9.8 0 -9.7 -9.7 11/24/2005 11:10:00 0.5 0.3 1.5 0.4 0.4 0.2 1.1 0.4 0.4 0.1 0.7 0.4 313 4 318 300 -9.8 0 -9.7 -9.7 11/24/2005 11:20:00 0.6 0.4 1.5 0.4 0.6 0.3 1.5 0.4 0.5 0.2 1.1 0.4 345 17 0 300 -9.8 0 -9.7 -9.7 11/24/2005 11:30:00 1.4 0.2 1.9 0.7 1.1 0.3 1.9 0.4 0.7 0.2 1.1 0.4 18 2 19 300 -9.7 0 -9.7 -9.7 11/24/2005 11:40:00 0.7 0.3 1.5 0.4 0.6 0.3 1.5 0.4 0.4 0.1 1.1 0.4 15 3 20 300 -9.6 0 -9.3 -9.7 11/24/2005 11:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 22 6 300 300 -9.4 0 -9.3 -9.5 11/24/2005 12:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 138 69 300 300 -9.4 0 -9.3 -9.3 11/24/2005 12:10:00 0.5 0.3 1.1 0.4 0.5 0.2 1.1 0.4 0.5 0.2 1.1 0.4 136 7 132 300 -9.3 0 -9.3 -9.3 11/24/2005 12:20:00 0.6 0.3 1.5 0.4 0.5 0.2 1.5 0.4 0.4 0.2 1.1 0.4 135 6 132 300 -9.3 0 -9.3 -9.3 11/24/2005 12:30:00 0.6 0.3 1.5 0.4 0.6 0.3 1.5 0.4 0.4 0.1 1.1 0.4 126 6 131 300 -9.3 0 -9.3 -9.3 11/24/2005 12:40:00 0.4 0.1 0.7 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 122 3 122 300 -9.3 0 -9.3 -9.3 11/24/2005 12:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 126 1 300 300 -9.3 0 -9.3 -9.3 11/24/2005 13:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 126 0 300 300 -9.3 0 -9.3 -9.3 11/24/2005 13:10:00 0.4 0.1 1.5 0.4 0.4 0.2 1.5 0.4 0.4 0 0.4 0.4 121 13 90 300 -9.2 0 -9.1 -9.3 11/24/2005 13:20:00 0.6 0.3 1.5 0.4 0.5 0.2 1.5 0.4 0.4 0 0.4 0.4 132 45 99 300 -9.2 0 -9.1 -9.3 11/24/2005 13:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 145 19 300 300 -9.2 0 -9.1 -9.3 11/24/2005 13:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 114 4 300 300 -9.1 0 -8.9 -9.1 11/24/2005 13:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 88 11 300 300 -9 0 -8.9 -9.1 11/24/2005 14:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 77 2 300 300 -8.9 0 -8.7 -8.9 11/24/2005 14:10:00 0.4 0 0.4 0.4 0.4 0.1 1.1 0.4 0.4 0 0.4 0.4 78 5 300 300 -8.7 0 -8.7 -8.9 11/24/2005 14:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 77 0 300 300 -8.9 0 -8.7 -9.1 11/24/2005 14:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 69 28 300 300 -9 0 -8.9 -9.1 11/24/2005 14:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 319 2 300 300 -9 0 -8.9 -9.1 11/24/2005 14:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 318 0 300 300 -9 0 -8.9 -9.1 11/24/2005 15:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 5 13 300 300 -8.9 0 -8.7 -8.9 11/24/2005 15:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 12 2 300 300 -8.8 0 -8.7 -8.9 11/24/2005 15:20:00 0.4 0 0.4 0.4 0.4 0 0.7 0.4 0.4 0 0.4 0.4 21 10 300 300 -8.7 0 -8.7 -8.9 11/24/2005 15:30:00 0.4 0 0.4 0.4 0.4 0.1 0.7 0.4 0.4 0 0.7 0.4 46 5 300 300 -8.7 0 -8.5 -8.7 11/24/2005 15:40:00 0.4 0 0.4 0.4 0.4 0.1 1.1 0.4 0.4 0 0.4 0.4 38 5 300 300 -8.7 0 -8.5 -8.7 11/24/2005 15:50:00 0.4 0 0.4 0.4 0.4 0.1 0.7 0.4 0.4 0 0.4 0.4 41 4 300 300 -8.7 0 -8.7 -8.9 11/24/2005 16:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 45 1 300 300 -8.9 0 -8.7 -8.9 11/24/2005 16:10:00 0.4 0.1 0.7 0.4 0.4 0.1 0.7 0.4 0.4 0 0.4 0.4 52 6 56 300 -9.1 0.1 -8.9 -9.3 11/24/2005 16:20:00 0.4 0.2 1.1 0.4 0.4 0.1 0.7 0.4 0.4 0 0.4 0.4 59 0 59 300 -9.3 0 -9.3 -9.3 11/24/2005 16:30:00 0.4 0.2 0.7 0.4 0.4 0 0.7 0.4 0.4 0 0.4 0.4 54 2 59 300 -9.3 0 -9.3 -9.3 11/24/2005 16:40:00 0.6 0.3 1.1 0.4 0.5 0.2 1.1 0.4 0.4 0 0.4 0.4 64 6 66 300 -9.6 0.1 -9.3 -9.7 11/24/2005 16:50:00 1 0.2 1.5 0.7 0.8 0.2 1.5 0.4 0.5 0.2 1.1 0.4 79 3 83 300 -9.8 0 -9.7 -10 11/24/2005 17:00:00 1 0.2 1.5 0.4 0.8 0.2 1.1 0.4 0.4 0 0.4 0.4 72 5 73 300 -10.1 0 -9.7 -10.2 11/24/2005 17:10:00 1.2 0.2 1.5 0.4 1 0.3 1.5 0.4 0.4 0 0.4 0.4 72 4 66 300 -10.3 0.1 -10 -10.4 11/24/2005 17:20:00 1.5 0.2 1.9 1.1 1.5 0.2 1.9 1.1 0.4 0 0.4 0.4 61 6 68 300 -10.5 0 -10.4 -10.6 11/24/2005 17:30:00 1.5 0.2 1.9 1.1 1.5 0.2 1.9 1.1 0.4 0 0.4 0.4 51 3 55 300 -10.6 0 -10.6 -10.8 11/24/2005 17:40:00 1.6 0.2 1.9 1.1 1.6 0.2 1.9 1.1 0.4 0 0.4 0.4 48 4 48 300 -10.5 0 -10.4 -10.6 11/24/2005 17:50:00 1.7 0.2 1.9 1.5 1.7 0.2 1.9 1.1 0.4 0 0.4 0.4 45 3 52 300 -10.4 0 -10.4 -10.6 11/24/2005 18:00:00 1.8 0.2 2.3 1.5 1.8 0.2 2.3 1.5 0.6 0.5 1.9 0.4 45 3 47 300 -10.4 0 -10.2 -10.4 11/24/2005 18:10:00 1.8 0.2 2.3 1.1 1.8 0.2 2.3 1.1 1.4 0.4 2.6 0.4 48 4 48 300 -10.4 0 -10.4 -10.6 11/24/2005 18:20:00 1.5 0.2 1.9 1.1 1.5 0.2 1.9 1.1 0.7 0.5 1.9 0.4 49 3 50 300 -10.4 0 -10.4 -10.6 11/24/2005 18:30:00 1.4 0.2 1.9 1.1 1.3 0.2 1.5 1.1 0.4 0 0.4 0.4 57 3 59 300 -10.5 0 -10.4 -10.8 11/24/2005 18:40:00 1.3 0.2 1.9 1.1 1.3 0.2 1.5 0.7 0.4 0 0.4 0.4 57 4 59 300 -10.9 0 -10.6 -11.2 11/24/2005 18:50:00 1.8 0.2 2.3 1.5 1.8 0.2 2.3 1.1 0.6 0.3 1.5 0.4 37 6 40 300 -11.2 0 -11 -11.4 11/24/2005 19:00:00 2.2 0.2 2.6 1.9 2.1 0.2 2.6 1.5 0.9 0.3 1.5 0.4 28 6 27 300 -11.5 0 -11.2 -11.8 11/24/2005 19:10:00 1.8 0.3 2.3 1.1 1.8 0.3 2.3 1.1 0.9 0.4 1.9 0.4 43 3 35 300 -11.7 0 -11.4 -11.8 11/24/2005 19:20:00 1.3 0.2 1.5 1.1 1.3 0.2 1.5 1.1 1.2 0.2 1.5 0.4 56 6 48 300 -11.5 0 -11.4 -11.6 11/24/2005 19:30:00 2.2 0.4 3 1.5 2.2 0.4 2.6 1.5 1.1 0.3 1.9 0.4 35 8 22 300 -11.9 0.1 -11.4 -12.2 11/24/2005 19:40:00 2.7 0.2 3 2.3 2.5 0.2 3 1.9 1.5 0.5 2.6 0.4 19 5 19 300 -12.1 0.1 -11.8 -12.2 11/24/2005 19:50:00 2.6 0.2 3 1.9 2.4 0.2 3 1.9 1.6 0.5 2.6 0.4 20 4 19 300 -11.6 0 -11.4 -11.8 11/24/2005 20:00:00 2.5 0.3 3 1.9 2.3 0.3 3 1.5 1.8 0.4 2.6 0.7 20 3 20 300 -11.4 0 -11.2 -11.4 11/24/2005 20:10:00 3 0.3 3.8 2.3 2.8 0.3 3.8 1.9 1.7 0.5 2.6 0.4 19 5 24 300 -11.6 0.1 -11.4 -11.8 11/24/2005 20:20:00 3.1 0.2 3.8 2.3 2.9 0.3 3.8 1.9 1.6 0.5 2.6 0.4 16 5 24 300 -12 0 -11.8 -12.2 11/24/2005 20:30:00 3.2 0.3 3.8 2.3 3.1 0.4 3.8 1.9 1.9 0.6 3.4 0.4 11 7 18 300 -11.8 0.1 -11.6 -12 11/24/2005 20:40:00 3.4 0.3 4.2 2.6 3.3 0.4 4.2 2.3 1.9 0.7 3.8 0.4 8 7 12 300 -11.7 0 -11.6 -11.8 11/24/2005 20:50:00 3.7 0.4 4.6 2.3 3.6 0.5 4.6 2.3 2.4 0.8 4.2 0.4 6 6 9 300 -11.7 0 -11.6 -11.8 11/24/2005 21:00:00 3.3 0.4 4.2 2.3 3.2 0.5 4.2 1.9 1.9 0.7 3.4 0.4 11 5 14 300 -11.7 0 -11.6 -11.8 11/24/2005 21:10:00 2.9 0.4 3.8 1.9 2.9 0.4 3.8 1.5 1.4 0.7 3 0.4 9 6 17 300 -11.7 0 -11.6 -11.8 11/24/2005 21:20:00 2.8 0.4 3.8 1.5 2.7 0.5 3.8 1.1 1.1 0.7 2.6 0.4 8 6 12 300 -11.7 0 -11.4 -11.8 11/24/2005 21:30:00 2.3 0.4 3 1.1 2 0.4 2.6 0.4 0.6 0.3 1.1 0.4 15 5 16 300 -12 0.1 -11.8 -12.2 11/24/2005 21:40:00 2.1 0.3 3 1.5 1.9 0.4 2.6 0.7 1.1 0.4 1.9 0.4 23 4 19 300 -12.5 0 -12.2 -12.6 11/24/2005 21:50:00 2 0.3 2.6 1.1 2 0.3 2.6 1.1 0.4 0 0.7 0.4 33 5 30 300 -12.9 0.2 -12.6 -13.2 11/24/2005 22:00:00 2.4 0.3 3 1.9 2.3 0.3 3 1.9 1.8 0.7 2.6 0.4 48 5 45 300 -13.5 0.1 -13.2 -13.6 11/24/2005 22:10:00 2.2 0.2 2.6 1.9 2.2 0.2 2.6 1.9 1.6 0.4 2.3 0.7 52 5 50 300 -13.2 0.1 -12.8 -13.6 11/24/2005 22:20:00 2.9 0.4 3.8 2.3 2.8 0.4 3.8 1.9 1.3 0.5 3.4 0.4 37 4 31 300 -12.6 0.1 -12.4 -12.8 11/24/2005 22:30:00 3.1 0.4 3.8 2.3 3.1 0.4 3.8 2.3 2.4 0.5 3.8 1.1 45 6 47 300 -12.3 0 -12 -12.4 11/24/2005 22:40:00 3.2 0.3 3.8 2.3 3.2 0.3 3.8 2.3 2.3 0.5 3.4 1.1 39 5 52 300 -11.9 0.1 -11.8 -12.2 11/24/2005 22:50:00 3.2 0.3 3.8 2.3 3.2 0.3 3.8 2.3 1.9 0.6 3.4 0.4 33 7 35 300 -11.7 0 -11.6 -11.8 11/24/2005 23:00:00 3.2 0.3 3.8 2.3 3.2 0.3 3.8 2.3 2.2 0.5 3.4 0.7 37 5 34 300 -11.7 0 -11.6 -11.8 11/24/2005 23:10:00 3.1 0.4 4.2 2.3 3.1 0.4 4.2 1.9 2.2 0.6 4.2 0.7 38 5 41 300 -11.5 0 -11.4 -11.6 11/24/2005 23:20:00 2.4 0.3 3 1.9 2.4 0.3 3.4 1.9 1.3 0.4 2.3 0.7 33 5 35 300 -11.3 0.1 -11 -11.4 11/24/2005 23:30:00 2.7 0.3 3.4 1.9 2.7 0.3 3.4 1.5 1.3 0.4 2.6 0.4 33 5 35 300 -11.1 0 -11 -11.2 11/24/2005 23:40:00 2.9 0.3 3.4 2.3 2.9 0.3 3.4 2.3 1.7 0.5 3 0.7 38 4 40 300 -11 0 -11 -11.2 11/24/2005 23:50:00 2.7 0.4 3.8 1.9 2.6 0.5 3.4 1.5 1.3 0.5 2.6 0.4 30 8 29 300 -10.8 0.1 -10.6 -11 11/25/2005 00:00:00 2.5 0.4 3.4 1.1 2.3 0.5 3.4 0.4 1 0.5 2.3 0.4 16 9 36 300 -10.6 0 -10.4 -10.6 11/25/2005 00:10:00 2.1 0.5 3 1.1 2 0.5 3 0.7 1.1 0.6 2.6 0.4 7 9 25 300 -10.6 0 -10.6 -10.8 11/25/2005 00:20:00 1.8 0.4 2.6 0.4 1.8 0.5 2.6 0.4 0.9 0.6 2.6 0.4 358 9 358 300 -10.8 0 -10.6 -11 11/25/2005 00:30:00 1.6 0.4 2.6 0.4 1.4 0.5 2.6 0.4 0.6 0.4 1.9 0.4 11 9 15 300 -10.9 0 -10.8 -11 11/25/2005 00:40:00 0.4 0.2 1.5 0.4 0.4 0.2 1.5 0.4 0.4 0 0.4 0.4 18 9 0 300 -11 0 -11 -11.2 11/25/2005 00:50:00 0.4 0.1 0.7 0.4 0.4 0.1 0.7 0.4 0.4 0.1 0.7 0.4 29 8 24 300 -11.2 0 -11 -11.2 11/25/2005 01:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 122 72 300 300 -11.2 0 -11.2 -11.4 11/25/2005 01:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 122 51 300 300 -11.3 0 -11.2 -11.4 11/25/2005 01:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 157 38 300 300 -11.3 0 -11.2 -11.4 11/25/2005 01:30:00 0.9 0.4 1.5 0.4 0.7 0.3 1.5 0.4 0.4 0 0.7 0.4 29 7 27 300 -11.3 0 -11.2 -11.4 11/25/2005 01:40:00 0.4 0.1 1.1 0.4 0.4 0.1 0.7 0.4 0.4 0 0.4 0.4 24 0 24 300 -11.4 0 -11.4 -11.4 11/25/2005 01:50:00 0.4 0.1 1.1 0.4 0.4 0.2 1.1 0.4 0.4 0 0.4 0.4 122 90 203 300 -11.5 0 -11.2 -11.4 11/25/2005 02:00:00 0.4 0.2 1.1 0.4 0.4 0.1 1.1 0.4 0.4 0 0.4 0.4 211 2 206 300 -11.5 0 -11.4 -11.4 11/25/2005 02:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 212 0 300 300 -11.5 0 -11.4 -11.4 11/25/2005 02:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 212 0 300 300 -11.5 0 -11.4 -11.4 11/25/2005 02:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 212 0 300 300 -11.5 0 -11.4 -11.4 11/25/2005 02:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 212 0 300 300 -11.5 0 -11.4 -11.4 11/25/2005 02:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 212 0 300 300 -11.4 0 -11.4 -11.4 11/25/2005 03:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 212 0 300 300 -11.3 0 -11.2 -11.4 11/25/2005 03:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 213 1 300 300 -11.2 0 -11 -11.4 11/25/2005 03:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 295 19 300 300 -11.2 0 -11 -11.4 11/25/2005 03:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 299 0 300 300 -11.3 0 -11.2 -11.4 11/25/2005 03:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 303 15 300 300 -11.2 0 -11.2 -11.4 11/25/2005 03:50:00 0.6 0.3 1.1 0.4 0.5 0.2 1.1 0.4 0.4 0 0.4 0.4 13 8 17 300 -11.2 0 -11 -11.2 11/25/2005 04:00:00 1.4 0.2 1.9 1.1 1.3 0.3 1.9 0.7 1 0.5 1.9 0.4 29 4 36 300 -11.1 0 -11 -11.2 11/25/2005 04:10:00 1.8 0.2 2.3 1.5 1.9 0.2 2.3 1.5 1.3 0.4 2.3 0.4 38 3 40 300 -10.9 0 -11 -11 11/25/2005 04:20:00 1.9 0.2 2.3 1.5 1.9 0.2 2.3 1.1 1.3 0.3 1.9 0.4 43 2 41 300 -10.9 0 -11 -11 11/25/2005 04:30:00 1.6 0.2 1.9 1.1 1.5 0.2 1.9 1.1 0.9 0.4 1.9 0.4 48 2 43 300 -10.9 0 -11 -11 11/25/2005 04:40:00 1.3 0.2 1.9 0.4 1.2 0.2 1.9 0.4 0.4 0 0.4 0.4 43 4 47 300 -10.9 0 -11 -11 11/25/2005 04:50:00 1.4 0.3 1.9 0.4 1.3 0.3 1.9 0.4 0.4 0 0.7 0.4 33 5 32 300 -10.9 0 -11 -11 11/25/2005 05:00:00 1.6 0.2 1.9 1.1 1.5 0.2 1.9 1.1 0.5 0.2 1.1 0.4 38 4 32 300 -10.9 0 -11 -11 11/25/2005 05:10:00 1.4 0.2 1.9 0.7 1.3 0.2 1.9 0.7 0.4 0 0.4 0.4 43 2 42 300 -10.9 0 -10.8 -11 11/25/2005 05:20:00 1.1 0.2 1.9 0.7 1.1 0.2 1.9 0.7 0.4 0 0.4 0.4 43 1 45 300 -10.9 0 -10.8 -11 11/25/2005 05:30:00 1 0.3 1.5 0.4 1 0.3 1.5 0.4 0.4 0.1 0.7 0.4 43 3 44 300 -10.8 0 -10.8 -11 11/25/2005 05:40:00 0.9 0.2 1.5 0.4 0.8 0.2 1.1 0.4 0.4 0 0.4 0.4 51 6 48 300 -10.9 0 -10.8 -11 11/25/2005 05:50:00 0.8 0.2 1.1 0.4 0.8 0.2 1.5 0.4 0.4 0 0.4 0.4 45 5 51 300 -11 0 -11 -11 11/25/2005 06:00:00 0.6 0.3 1.1 0.4 0.5 0.2 1.1 0.4 0.4 0.2 1.1 0.4 39 6 40 300 -11.1 0 -11 -11.2 11/25/2005 06:10:00 0.6 0.3 1.5 0.4 0.6 0.3 1.5 0.4 0.4 0.1 1.1 0.4 43 2 42 300 -11.2 0 -11 -11.4 11/25/2005 06:20:00 0.8 0.3 1.5 0.4 0.8 0.3 1.5 0.4 0.4 0.2 1.1 0.4 41 6 42 300 -11.4 0 -11.2 -11.4 11/25/2005 06:30:00 0.7 0.3 1.1 0.4 0.6 0.2 1.1 0.4 0.5 0.2 1.1 0.4 28 4 30 300 -11.2 0 -11 -11.4 11/25/2005 06:40:00 0.4 0.1 1.1 0.4 0.4 0.1 0.7 0.4 0.4 0.1 0.7 0.4 22 2 27 300 -11.2 0 -11.2 -11.4 11/25/2005 06:50:00 0.6 0.2 1.1 0.4 0.5 0.2 1.1 0.4 0.4 0.2 1.1 0.4 22 2 21 300 -11.3 0 -11 -11.4 11/25/2005 07:00:00 1.1 0.2 1.5 0.4 1.1 0.2 1.9 0.4 1.5 0.4 1.9 0.4 36 5 32 300 -11.8 0.2 -11.4 -12 11/25/2005 07:10:00 1.5 0.2 1.9 1.1 1.5 0.2 1.9 1.1 1.6 0.2 1.9 1.1 47 4 43 300 -12.1 0 -12 -12.2 11/25/2005 07:20:00 1.7 0.2 1.9 1.5 1.6 0.2 1.9 1.1 1.5 0.3 2.3 1.1 66 6 57 300 -12.3 0 -12.2 -12.2 11/25/2005 07:30:00 1.6 0.2 2.3 1.1 1.5 0.2 2.3 1.1 1.8 0.2 2.3 1.5 71 3 66 300 -12.3 0 -12.2 -12.4 11/25/2005 07:40:00 2.3 0.3 3 1.9 2.3 0.3 3 1.9 1.9 0.3 2.6 1.1 50 6 45 300 -12.3 0 -12.2 -12.4 11/25/2005 07:50:00 2.6 0.2 3 1.9 2.7 0.2 3 1.9 1.7 0.4 2.6 0.7 42 3 43 300 -12.2 0.1 -12 -12.2 11/25/2005 08:00:00 2.8 0.2 3.4 2.3 2.8 0.2 3.4 2.3 1.7 0.4 2.6 0.7 41 3 41 300 -11.7 0.1 -11.4 -12 11/25/2005 08:10:00 2.7 0.2 3 2.3 2.7 0.2 3 2.3 2 0.3 2.6 1.1 45 4 41 300 -11.6 0 -11.4 -11.6 11/25/2005 08:20:00 2.8 0.2 3 1.9 2.9 0.2 3 2.3 2.1 0.4 2.6 0.7 49 3 55 300 -11.6 0 -11.4 -11.8 11/25/2005 08:30:00 2.7 0.4 3.4 1.5 2.7 0.4 3.4 1.5 1.7 0.6 3 0.4 43 5 40 300 -11.5 0 -11.4 -11.6 11/25/2005 08:40:00 2.7 0.3 3.4 1.9 2.7 0.3 3.4 1.9 1.7 0.4 2.6 0.7 41 4 41 300 -11.2 0 -11.2 -11.4 11/25/2005 08:50:00 2.8 0.2 3.4 2.3 2.8 0.2 3.4 2.3 2 0.4 3 1.1 42 4 46 300 -11.1 0 -11 -11.2 11/25/2005 09:00:00 2.7 0.3 3.4 1.5 2.7 0.3 3.4 1.9 1.7 0.5 2.6 0.4 43 5 53 300 -11 0 -11 -11.2 11/25/2005 09:10:00 2.4 0.3 3 1.9 2.4 0.3 3 1.5 1.4 0.4 2.3 0.4 39 4 43 300 -10.9 0 -11 -11 11/25/2005 09:20:00 2.4 0.2 3 1.9 2.4 0.2 3 1.9 1.4 0.3 2.3 0.7 42 3 42 300 -10.9 0 -11 -11 11/25/2005 09:30:00 2.5 0.2 3 1.9 2.5 0.2 3 1.9 1.2 0.3 1.9 0.4 38 5 40 300 -10.9 0 -11 -11 11/25/2005 09:40:00 2.5 0.2 3 1.9 2.5 0.2 3 1.9 1.4 0.4 2.3 0.4 35 3 30 300 -10.9 0 -10.8 -11 11/25/2005 09:50:00 2.4 0.3 3 1.1 2.4 0.3 3 1.1 1.6 0.4 2.6 0.7 38 5 40 300 -10.9 0 -10.8 -11 11/25/2005 10:00:00 2.3 0.3 3 1.5 2.3 0.3 3 1.1 1.2 0.4 2.3 0.4 36 5 43 300 -10.8 0 -10.6 -11 11/25/2005 10:10:00 2.3 0.3 2.6 1.5 2.3 0.3 2.6 1.5 1 0.4 2.3 0.4 33 5 35 300 -10.8 0 -10.6 -10.8 11/25/2005 10:20:00 2.3 0.3 3 1.5 2.2 0.3 2.6 1.5 1 0.4 1.9 0.4 32 6 28 300 -10.7 0 -10.6 -10.8 11/25/2005 10:30:00 2.3 0.2 2.6 1.5 2.3 0.2 2.6 1.5 1.1 0.3 2.3 0.4 32 6 29 300 -10.7 0 -10.6 -10.8 11/25/2005 10:40:00 2.5 0.2 3 1.9 2.3 0.3 3 1.5 1.2 0.4 2.3 0.4 16 7 24 300 -10.5 0 -10.4 -10.6 11/25/2005 10:50:00 2.3 0.2 3 1.5 2.2 0.3 2.6 1.5 1 0.4 1.9 0.4 21 6 32 300 -10.4 0 -10.4 -10.6 11/25/2005 11:00:00 2.1 0.2 2.6 1.5 2 0.3 2.6 1.1 0.8 0.3 1.9 0.4 22 5 13 300 -10.4 0 -10.2 -10.4 11/25/2005 11:10:00 2.5 0.2 3 1.9 2.4 0.2 2.6 1.5 1 0.3 1.9 0.4 25 3 27 300 -10.4 0 -10.4 -10.6 11/25/2005 11:20:00 2.5 0.2 3 2.3 2.5 0.2 3 1.9 1.1 0.3 1.9 0.4 30 5 22 300 -10.4 0 -10.4 -10.6 11/25/2005 11:30:00 2.2 0.2 2.6 1.9 2.1 0.2 2.6 1.5 1 0.3 1.9 0.4 28 6 36 300 -10.5 0 -10.4 -10.6 11/25/2005 11:40:00 2.2 0.2 2.6 1.5 2.2 0.3 3 1.1 1.2 0.3 1.9 0.4 30 4 31 300 -10.5 0 -10.4 -10.6 11/25/2005 11:50:00 2.7 0.3 3 2.3 2.5 0.3 3 1.5 1.4 0.4 2.6 0.4 23 5 21 300 -10.7 0 -10.6 -10.8 11/25/2005 12:00:00 2.5 0.4 3.4 1.5 2.3 0.4 3 1.1 1.5 0.6 2.6 0.4 14 6 19 300 -10.6 0 -10.4 -10.8 11/25/2005 12:10:00 1.5 0.5 2.6 0.7 1.4 0.5 2.3 0.4 1 0.3 1.5 0.4 17 6 20 300 -10.4 0 -10.4 -10.6 11/25/2005 12:20:00 2.1 0.4 2.6 1.1 2 0.4 2.6 0.7 1.5 0.3 2.3 0.7 12 6 10 300 -10.7 0.2 -10.4 -11 11/25/2005 12:30:00 2.7 0.3 3.4 1.9 2.6 0.3 3 1.5 1.4 0.5 2.3 0.4 12 5 13 300 -11.1 0.1 -11 -11.4 11/25/2005 12:40:00 2.7 0.4 3 1.5 2.4 0.3 3 1.5 1.6 0.4 2.6 0.4 22 4 19 300 -11.2 0.1 -11 -11.4 11/25/2005 12:50:00 2.8 0.3 3.4 2.3 2.6 0.4 3.4 1.9 1.6 0.4 2.6 0.7 19 4 14 300 -10.7 0 -10.6 -11 11/25/2005 13:00:00 2.8 0.4 3.4 1.1 2.6 0.4 3.4 1.5 1.2 0.5 2.3 0.4 23 8 17 300 -10.8 0 -10.6 -11 11/25/2005 13:10:00 2.6 0.2 3 2.3 2.6 0.2 3 2.3 1.4 0.4 2.3 0.4 43 10 31 300 -10.8 0 -10.6 -11 11/25/2005 13:20:00 2.6 0.3 3.4 1.9 2.6 0.3 3.4 1.9 1.7 0.3 2.3 0.7 45 4 43 300 -10.9 0 -10.8 -11 11/25/2005 13:30:00 1.5 0.4 2.6 0.7 1.5 0.4 2.6 0.4 0.8 0.3 1.5 0.4 19 12 42 300 -10.5 0.2 -10.4 -11 11/25/2005 13:40:00 1.7 0.5 2.6 0.7 1.6 0.5 2.6 0.7 1 0.5 1.9 0.4 359 11 358 300 -10.8 0.2 -10.4 -11 11/25/2005 13:50:00 0.4 0.1 1.1 0.4 0.4 0.1 1.1 0.4 0.4 0 0.4 0.4 321 7 333 300 -11.2 0.1 -11 -11.8 11/25/2005 14:00:00 0.5 0.4 1.5 0.4 0.5 0.3 1.5 0.4 0.4 0 0.4 0.4 320 23 346 300 -12 0.1 -11.6 -12.4 11/25/2005 14:10:00 1.3 0.6 2.3 0.4 1.2 0.6 2.6 0.4 0.5 0.2 1.1 0.4 0 14 9 300 -12.5 0 -12.2 -12.8 11/25/2005 14:20:00 2.3 0.4 3 1.5 2.2 0.5 3 1.5 1.8 0.5 2.6 0.4 9 6 358 300 -13 0 -12.8 -13.2 11/25/2005 14:30:00 2.9 0.3 3.4 1.9 2.9 0.3 3.8 1.9 1.6 0.3 2.3 0.7 2 3 5 300 -12.8 0 -12.6 -13 11/25/2005 14:40:00 2.6 0.3 3 1.9 2.5 0.4 3 1.5 1.5 0.3 2.3 0.7 9 6 6 300 -12.6 0.2 -12.2 -13 11/25/2005 14:50:00 1.9 0.4 3 1.5 1.8 0.3 3 1.5 1 0.3 1.9 0.4 31 5 24 300 -12.2 0.2 -12 -12.6 11/25/2005 15:00:00 3.4 0.4 4.6 2.3 3.5 0.5 4.6 1.9 2.2 0.6 3 0.7 5 5 357 300 -12.6 0 -12.4 -12.8 11/25/2005 15:10:00 3.4 0.5 4.6 1.9 3.1 0.5 4.2 1.9 1.7 0.4 3 0.4 18 7 14 300 -12.5 0 -12.2 -12.6 11/25/2005 15:20:00 3 0.5 4.6 2.3 2.5 0.5 3.8 1.5 1.3 0.3 2.3 0.4 22 6 23 300 -12.3 0 -12.2 -12.6 11/25/2005 15:30:00 4.1 0.6 5.3 2.3 3.7 0.5 4.9 2.3 1.9 0.5 3.4 0.7 28 8 17 300 -12.3 0 -12.2 -12.4 11/25/2005 15:40:00 2.8 0.5 4.2 1.9 2.7 0.5 4.2 1.9 1.2 0.5 2.6 0.4 37 5 39 300 -12.3 0.1 -12.2 -12.6 11/25/2005 15:50:00 2.1 0.3 2.6 1.5 2.1 0.3 2.6 1.5 1.1 0.3 1.9 0.4 43 3 41 300 -12.7 0.1 -12.4 -13.2 11/25/2005 16:00:00 2 0.3 2.6 1.1 2 0.3 2.6 1.1 1 0.2 1.5 0.4 51 6 44 300 -13.3 0.1 -13 -13.6 11/25/2005 16:10:00 2.5 0.5 3.4 1.5 2.5 0.5 3.4 1.1 1.2 0.4 2.3 0.4 51 6 52 300 -13.2 0.1 -13.2 -13.6 11/25/2005 16:20:00 0.5 0.4 1.9 0.4 0.5 0.3 1.5 0.4 0.4 0.1 0.7 0.4 74 10 70 300 -13.6 0.1 -13.2 -13.6 11/25/2005 16:30:00 1.2 0.6 2.3 0.4 1.2 0.6 2.3 0.4 1.3 0.5 2.3 0.4 304 56 297 300 -13.3 0 -13.2 -13.6 11/25/2005 16:40:00 1.8 0.4 2.6 0.7 1.6 0.5 2.6 0.4 0.9 0.5 1.9 0.4 301 5 300 300 -13.5 0.2 -13.2 -13.8 11/25/2005 16:50:00 1.9 0.4 2.6 0.7 1.8 0.5 2.6 0.4 1.7 0.4 2.3 0.7 310 7 306 300 -14.1 0.1 -13.8 -14.4 11/25/2005 17:00:00 2.5 0.2 3 1.9 2.5 0.2 3 1.9 1.4 0.3 2.3 0.7 339 6 327 300 -13.8 0 -13.6 -14 11/25/2005 17:10:00 2 0.5 3 1.1 2 0.6 3 0.7 0.9 0.6 2.3 0.4 353 8 346 300 -14.1 0 -14 -14.2 11/25/2005 17:20:00 1.6 1.2 3.8 0.4 1.6 1.2 3.4 0.4 1.3 0.8 3 0.4 93 107 189 300 -14.3 0.1 -14 -14.6 11/25/2005 17:30:00 2.1 0.4 3 1.5 2.8 0.4 3.8 1.9 1.9 0.3 3 1.1 204 7 206 300 -14.9 0.1 -14.6 -15.1 11/25/2005 17:40:00 2.1 0.5 3 1.1 2.3 0.7 3.8 0.7 1 0.5 1.9 0.4 232 17 215 300 -15.3 0.1 -15 -15.5 11/25/2005 17:50:00 1.4 0.4 2.3 0.7 1.2 0.4 1.9 0.4 0.4 0 0.4 0.4 243 8 254 300 -15.7 0.1 -15.5 -15.9 11/25/2005 18:00:00 0.8 0.3 1.9 0.4 0.7 0.4 1.9 0.4 0.4 0 0.7 0.4 193 17 190 300 -15.9 0 -15.9 -15.9 11/25/2005 18:10:00 1.1 0.6 2.6 0.4 1 0.5 2.3 0.4 0.4 0 0.4 0.4 238 35 263 300 -15.9 0 -15.9 -15.9 11/25/2005 18:20:00 2 0.4 3.4 0.7 1.8 0.5 3.4 0.4 1.1 0.5 2.6 0.4 285 14 269 300 -15.8 0.1 -15.3 -15.9 11/25/2005 18:30:00 2.4 0.6 3.4 1.1 2.3 0.6 3.8 0.4 1.4 0.5 2.6 0.4 275 11 289 300 -15.3 0.1 -15.1 -15.5 11/25/2005 18:40:00 1.7 0.4 2.6 0.7 1.5 0.4 2.6 0.7 0.7 0.4 1.5 0.4 248 11 258 300 -15.6 0.2 -15 -15.9 11/25/2005 18:50:00 1.3 0.4 1.9 0.4 1.1 0.5 1.9 0.4 0.4 0.2 1.1 0.4 280 26 245 300 -16.1 0 -15.9 -16.3 11/25/2005 19:00:00 0.8 0.5 1.9 0.4 0.6 0.4 1.9 0.4 0.9 0.4 1.5 0.4 0 20 13 300 -16.2 0.1 -15.9 -16.3 11/25/2005 19:10:00 0.4 0.2 1.5 0.4 0.4 0.1 1.1 0.4 0.5 0.3 1.5 0.4 53 56 30 300 -15.9 0 -15.7 -16.1 11/25/2005 19:20:00 0.5 0.3 1.5 0.4 0.4 0.2 1.1 0.4 0.5 0.4 2.3 0.4 234 66 227 300 -16.4 0.2 -15.9 -16.9 11/25/2005 19:30:00 1.1 0.6 2.3 0.4 1 0.6 2.3 0.4 1.1 0.7 2.3 0.4 321 27 332 300 -16.2 0.1 -15.9 -16.5 11/25/2005 19:40:00 1.5 0.3 2.3 0.7 1.3 0.3 1.9 0.4 0.9 0.3 1.5 0.4 297 9 274 300 -16.4 0.1 -16.1 -16.7 11/25/2005 19:50:00 0.9 0.4 1.5 0.4 0.6 0.4 1.5 0.4 0.5 0.2 1.1 0.4 286 20 309 300 -16.9 0 -16.7 -17.1 11/25/2005 20:00:00 0.7 0.3 1.5 0.4 0.5 0.2 1.1 0.4 0.4 0.1 0.7 0.4 285 18 295 300 -16.8 0 -16.7 -17.1 11/25/2005 20:10:00 0.5 0.2 1.1 0.4 0.4 0.1 1.1 0.4 0.4 0 0.4 0.4 251 6 249 300 -16.7 0 -16.5 -16.9 11/25/2005 20:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 264 0 300 300 -16.4 0 -16.3 -16.5 11/25/2005 20:30:00 0.6 0.3 1.5 0.4 0.5 0.2 1.1 0.4 0.5 0.2 1.1 0.4 273 6 278 300 -16.5 0 -16.5 -16.5 11/25/2005 20:40:00 0.4 0.1 0.7 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 279 0 279 300 -16.5 0 -16.5 -16.7 11/25/2005 20:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 279 0 300 300 -16.5 0.2 -16.1 -16.7 11/25/2005 21:00:00 0.6 0.3 1.5 0.4 0.4 0.2 1.1 0.4 0.4 0 0.4 0.4 240 13 247 300 -16 0 -15.9 -16.3 11/25/2005 21:10:00 0.9 0.5 2.3 0.4 0.7 0.5 2.3 0.4 0.5 0.2 1.5 0.4 240 8 237 300 -15.7 0.1 -15.3 -15.9 11/25/2005 21:20:00 1.6 0.4 2.3 0.4 1.5 0.3 2.6 0.7 1.2 0.3 2.3 0.4 218 8 220 300 -15.8 0.1 -15.5 -15.9 11/25/2005 21:30:00 1.6 0.4 2.3 0.4 1.7 0.3 2.3 0.7 0.9 0.4 1.9 0.4 217 5 215 300 -16 0.1 -15.9 -16.3 11/25/2005 21:40:00 1.7 0.4 2.3 0.7 1.7 0.3 2.3 1.1 0.8 0.4 1.5 0.4 194 15 187 300 -16.3 0 -16.1 -16.5 11/25/2005 21:50:00 0.5 0.3 1.9 0.4 0.5 0.3 1.9 0.4 0.4 0.1 0.7 0.4 196 4 181 300 -16.7 0 -16.5 -16.9 11/25/2005 22:00:00 0.4 0 0.7 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 192 15 180 300 -16.7 0.1 -16.5 -17.1 11/25/2005 22:10:00 0.4 0 0.7 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 171 22 106 300 -17.3 0.1 -17.1 -17.4 11/25/2005 22:20:00 0.4 0 0.7 0.4 0.4 0 0.4 0.4 0.4 0.1 0.7 0.4 168 58 135 300 -17.6 0 -17.2 -17.8 11/25/2005 22:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0.1 0.7 0.4 211 45 300 300 -17.8 0.2 -17.4 -18 11/25/2005 22:40:00 0.9 0.4 1.9 0.4 0.8 0.4 1.5 0.4 0.7 0.3 1.5 0.4 114 10 98 300 -18.4 0.2 -18 -18.5 11/25/2005 22:50:00 0.7 0.3 1.5 0.4 0.6 0.3 1.5 0.4 0.5 0.2 1.1 0.4 111 9 109 300 -18.5 0 -18.4 -18.5 11/25/2005 23:00:00 0.7 0.5 1.9 0.4 0.6 0.4 1.9 0.4 0.9 0.3 1.5 0.4 69 12 75 300 -18.4 0.1 -18.2 -18.5 11/25/2005 23:10:00 0.4 0.1 1.1 0.4 0.4 0.1 1.1 0.4 0.6 0.3 1.1 0.4 64 4 49 300 -18.4 0.1 -18 -18.5 11/25/2005 23:20:00 0.9 0.5 1.9 0.4 0.8 0.4 1.9 0.4 0.9 0.3 1.5 0.4 41 10 32 300 -18.2 0.1 -18 -18.5 11/25/2005 23:30:00 1.1 0.3 1.9 0.4 1 0.4 1.9 0.4 1.3 0.2 1.9 0.7 40 8 46 300 -18.1 0.4 -17.2 -18.5 11/25/2005 23:40:00 0.5 0.2 1.1 0.4 0.4 0.1 1.1 0.4 0.6 0.2 1.1 0.4 20 9 33 300 -17.3 0.1 -17.1 -17.4 11/25/2005 23:50:00 0.5 0.2 1.5 0.4 0.4 0.2 1.1 0.4 0.4 0 0.7 0.4 318 79 193 300 -17.6 0.1 -17.4 -17.8 11/26/2005 00:00:00 0.9 0.4 1.5 0.4 0.7 0.3 1.5 0.4 0.4 0 0.7 0.4 226 17 229 300 -17.8 0.1 -17.1 -18 11/26/2005 00:10:00 1.6 0.3 2.3 0.7 1.4 0.3 2.3 0.7 0.9 0.4 1.9 0.4 249 6 260 300 -18.3 0.1 -17.8 -18.5 11/26/2005 00:20:00 1.4 0.5 2.3 0.7 1.1 0.5 2.3 0.4 0.7 0.5 1.9 0.4 243 5 254 300 -18.3 0.1 -18 -18.5 11/26/2005 00:30:00 1.2 0.3 1.9 0.4 0.9 0.3 1.9 0.4 0.4 0 0.7 0.4 235 10 251 300 -18.7 0 -18.5 -19.1 11/26/2005 00:40:00 0.5 0.2 1.1 0.4 0.4 0 0.7 0.4 0.4 0 0.4 0.4 227 1 227 300 -19.3 0.1 -18.9 -19.4 11/26/2005 00:50:00 0.4 0 0.7 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 233 14 256 300 -19.3 0.1 -19.1 -19.6 11/26/2005 01:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 248 9 300 300 -19.3 0.1 -19.1 -19.6 11/26/2005 01:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 239 0 300 300 -19.6 0 -19.4 -19.8 11/26/2005 01:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 266 32 300 300 -19.8 0 -19.4 -19.8 11/26/2005 01:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0.2 1.1 0.4 1 23 300 300 -19.8 0.1 -19.4 -20 11/26/2005 01:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.7 0.4 15 0 300 300 -19.4 0.2 -19.1 -19.8 11/26/2005 01:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.7 0.4 24 5 300 300 -19.6 0.2 -19.1 -19.8 11/26/2005 02:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.7 0.4 27 0 300 300 -19.7 0 -19.6 -19.8 11/26/2005 02:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 21 6 300 300 -19.6 0.1 -19.3 -19.8 11/26/2005 02:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 355 27 300 300 -19.6 0.1 -19.3 -19.8 11/26/2005 02:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 317 0 300 300 -19.9 0 -19.8 -20 11/26/2005 02:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 316 0 300 300 -20 0 -19.8 -20.2 11/26/2005 02:50:00 0.7 0.4 1.5 0.4 0.5 0.3 1.5 0.4 0.6 0.4 1.9 0.4 324 7 328 300 -19.3 0.6 -18.4 -20.2 11/26/2005 03:00:00 0.8 0.4 1.5 0.4 0.5 0.3 1.5 0.4 1.1 0.3 1.5 0.4 325 9 330 300 -17.9 0.1 -17.6 -18.4 11/26/2005 03:10:00 0.8 0.3 1.5 0.4 0.5 0.2 1.1 0.4 0.6 0.2 1.1 0.4 292 13 309 300 -18.1 0.1 -18 -18.5 11/26/2005 03:20:00 0.4 0.1 0.7 0.4 0.4 0 0.7 0.4 0.4 0 0.4 0.4 277 20 272 300 -18.9 0.2 -18.5 -19.1 11/26/2005 03:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 250 0 300 300 -19.6 0.1 -19.1 -19.8 11/26/2005 03:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 250 0 300 300 -19.6 0 -19.3 -19.8 11/26/2005 03:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 284 39 300 300 -19.6 0.1 -19.3 -19.8 11/26/2005 04:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0.2 1.1 0.4 351 22 300 300 -19.8 0 -19.6 -20 11/26/2005 04:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0.1 1.1 0.4 18 0 300 300 -20.1 0.1 -19.8 -20.3 11/26/2005 04:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 345 43 300 300 -19.8 0 -19.6 -20 11/26/2005 04:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 273 8 300 300 -20.1 0.1 -19.8 -20.3 11/26/2005 04:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 265 0 300 300 -20.4 0.1 -20.2 -20.7 11/26/2005 04:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 265 0 300 300 -20.6 0.1 -20.3 -20.9 11/26/2005 05:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 265 0 300 300 -20.9 0 -20.7 -21.1 11/26/2005 05:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.7 0.4 300 30 300 300 -21 0.2 -20.7 -21.2 11/26/2005 05:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 286 22 300 300 -20.8 0.1 -20.5 -21.1 11/26/2005 05:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 238 0 300 300 -21.1 0.2 -20.7 -21.6 11/26/2005 05:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 238 0 300 300 -21.3 0.1 -21.1 -21.6 11/26/2005 05:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 238 0 300 300 -21.2 0 -20.9 -21.4 11/26/2005 06:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 238 0 300 300 -21.4 0.1 -21.1 -21.6 11/26/2005 06:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 239 2 300 300 -21.8 0.1 -21.6 -21.9 11/26/2005 06:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.7 0.4 333 51 300 300 -21.9 0 -21.6 -21.9 11/26/2005 06:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.7 0.4 36 0 300 300 -21.9 0.1 -21.6 -21.9 11/26/2005 06:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 36 0 300 300 -21.4 0.4 -20.5 -21.8 11/26/2005 06:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 36 0 300 300 -21.1 0.4 -20.3 -21.8 11/26/2005 07:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 17 28 300 300 -21.9 0 -21.6 -22.1 11/26/2005 07:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 325 8 300 300 -22.2 0.1 -21.9 -22.3 11/26/2005 07:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 297 5 300 300 -22.5 0 -22.3 -22.6 11/26/2005 07:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 296 0 300 300 -22.5 0.1 -22.3 -22.8 11/26/2005 07:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 271 32 300 300 -22.3 0.1 -22.1 -22.5 11/26/2005 07:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 231 0 300 300 -22.5 0 -22.3 -22.6 11/26/2005 08:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 227 5 300 300 -22.6 0 -22.5 -22.8 11/26/2005 08:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 218 0 300 300 -22.6 0.1 -22.5 -22.8 11/26/2005 08:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 222 7 300 300 -22.5 0.1 -22.1 -23 11/26/2005 08:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 241 0 300 300 -22.3 0.1 -21.9 -22.5 11/26/2005 08:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 252 10 300 300 -22.7 0.1 -22.5 -23 11/26/2005 08:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 283 7 300 300 -22.6 0.1 -22.3 -23 11/26/2005 09:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 263 8 300 300 -22.6 0.1 -22.3 -23 11/26/2005 09:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 280 13 300 300 -22.5 0.3 -21.9 -23 11/26/2005 09:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 256 10 300 300 -22.1 0.1 -21.9 -22.3 11/26/2005 09:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 256 5 300 300 -22.2 0 -22.1 -22.3 11/26/2005 09:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 261 6 300 300 -22.3 0.1 -21.9 -22.5 11/26/2005 09:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 264 0 300 300 -22.5 0 -22.5 -22.6 11/26/2005 10:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 291 69 300 300 -22.6 0.1 -22.5 -22.8 11/26/2005 10:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 133 35 300 300 -22.5 0.2 -22.3 -22.8 11/26/2005 10:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 184 20 300 300 -21.9 0.3 -21.2 -22.3 11/26/2005 10:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 154 28 300 300 -21.6 0.3 -21.2 -22.1 11/26/2005 10:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 136 0 300 300 -21.9 0.1 -21.6 -22.3 11/26/2005 10:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 212 15 300 300 -21.5 0 -21.4 -21.6 11/26/2005 11:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 247 33 300 300 -21.6 0.2 -21.4 -21.8 11/26/2005 11:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 284 0 300 300 -21.8 0.1 -21.6 -21.9 11/26/2005 11:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 215 39 300 300 -21.1 0.2 -20.9 -21.6 11/26/2005 11:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 184 0 300 300 -20.6 0.2 -20.2 -20.9 11/26/2005 11:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 184 1 300 300 -20 0.1 -19.8 -20.3 11/26/2005 11:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 265 23 300 300 -19.9 0.1 -19.4 -20 11/26/2005 12:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 291 13 300 300 -19.6 0.1 -19.3 -19.8 11/26/2005 12:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 330 0 300 300 -19.3 0.1 -18.9 -19.8 11/26/2005 12:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 331 0 300 300 -18.8 0.1 -18.5 -19.1 11/26/2005 12:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 15 47 300 300 -18.3 0.2 -17.8 -18.5 11/26/2005 12:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 69 9 300 300 -17.8 0 -17.4 -18 11/26/2005 12:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 74 9 300 300 -17.4 0 -17.2 -17.4 11/26/2005 13:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 35 9 300 300 -17.8 0.2 -17.4 -18 11/26/2005 13:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 12 4 300 300 -17.5 0.2 -17.1 -18 11/26/2005 13:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 8 7 300 300 -16.6 0.3 -16.1 -17.1 11/26/2005 13:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 320 7 300 300 -16.2 0 -15.9 -16.5 11/26/2005 13:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 323 9 300 300 -16.3 0 -16.1 -16.5 11/26/2005 13:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 351 17 300 300 -16.5 0.2 -16.1 -17.1 11/26/2005 14:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 2 3 300 300 -17.2 0.2 -17.1 -17.4 11/26/2005 14:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 314 13 300 300 -17.6 0 -17.4 -17.8 11/26/2005 14:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 296 6 300 300 -17.9 0.1 -17.4 -18 11/26/2005 14:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 304 8 300 300 -18.3 0.2 -18 -18.5 11/26/2005 14:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 316 1 300 300 -18.7 0 -18.5 -18.9 11/26/2005 14:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 318 15 300 300 -18.9 0 -18.5 -19.1 11/26/2005 15:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 299 5 300 300 -18.6 0 -18.5 -18.7 11/26/2005 15:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 294 5 300 300 -18.8 0.1 -18.5 -18.9 11/26/2005 15:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 282 13 300 300 -19 0.1 -18.9 -19.1 11/26/2005 15:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 275 4 300 300 -19.1 0 -18.9 -19.1 11/26/2005 15:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 277 0 300 300 -19.4 0.2 -19.1 -19.8 11/26/2005 15:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 288 10 300 300 -20 0.1 -19.6 -20.2 11/26/2005 16:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 310 8 300 300 -19.9 0.3 -19.3 -20.3 11/26/2005 16:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 314 3 300 300 -19.4 0.2 -19.1 -19.8 11/26/2005 16:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 297 7 300 300 -20.3 0.2 -19.8 -20.7 11/26/2005 16:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 324 35 300 300 -20.8 0.1 -20.5 -20.9 11/26/2005 16:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 4 0 300 300 -20.8 0 -20.7 -20.9 11/26/2005 16:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 4 0 300 300 -20.8 0.1 -20.5 -20.9 11/26/2005 17:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0 4 300 300 -20.2 0.2 -19.8 -20.5 11/26/2005 17:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 325 11 300 300 -20.3 0.1 -19.8 -20.5 11/26/2005 17:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 287 29 300 300 -20.6 0 -20.3 -20.7 11/26/2005 17:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 243 5 300 300 -20.7 0 -20.5 -20.9 11/26/2005 17:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 228 9 300 300 -20.8 0 -20.5 -20.9 11/26/2005 17:50:00 0.4 0 0.7 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 195 12 208 300 -20.9 0.2 -20.5 -21.4 11/26/2005 18:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 182 0 300 300 -21.6 0.2 -21.2 -21.9 11/26/2005 18:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 182 0 300 300 -21.2 0 -21.1 -21.4 11/26/2005 18:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 182 0 300 300 -21.3 0 -21.1 -21.4 11/26/2005 18:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 182 0 300 300 -21.6 0.2 -21.2 -21.9 11/26/2005 18:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 239 45 300 300 -21.8 0.1 -21.4 -21.9 11/26/2005 18:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 283 0 300 300 -21.6 0.1 -21.4 -21.9 11/26/2005 19:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 283 0 300 300 -22 0.1 -21.8 -22.3 11/26/2005 19:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 283 0 300 300 -21.8 0.2 -21.6 -22.3 11/26/2005 19:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 283 0 300 300 -21.6 0.2 -21.4 -21.9 11/26/2005 19:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 260 35 300 300 -22.2 0.1 -21.9 -22.3 11/26/2005 19:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 205 0 300 300 -22.3 0.2 -21.9 -22.5 11/26/2005 19:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 205 0 300 300 -22 0 -21.9 -22.3 11/26/2005 20:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 205 0 300 300 -22.4 0.1 -21.9 -22.5 11/26/2005 20:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 205 0 300 300 -22.5 0 -22.5 -22.6 11/26/2005 20:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 320 79 300 300 -22.4 0 -22.3 -22.5 11/26/2005 20:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 7 3 300 300 -22.4 0 -22.3 -22.5 11/26/2005 20:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 5 0 300 300 -22.5 0 -22.5 -22.6 11/26/2005 20:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 2 5 300 300 -22.5 0.1 -22.3 -22.6 11/26/2005 21:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 321 22 300 300 -22.1 0.1 -21.9 -22.3 11/26/2005 21:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 293 12 300 300 -22.4 0 -22.3 -22.5 11/26/2005 21:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 251 0 300 300 -22.7 0.1 -22.5 -23 11/26/2005 21:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 251 0 300 300 -22.7 0.1 -22.5 -23 11/26/2005 21:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 251 0 300 300 -22.5 0.1 -22.1 -22.8 11/26/2005 21:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 251 0 300 300 -21.9 0 -21.8 -22.1 11/26/2005 22:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 251 0 300 300 -22 0 -21.8 -22.3 11/26/2005 22:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 290 19 300 300 -21.5 0.1 -21.4 -21.9 11/26/2005 22:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 300 0 300 300 -21.7 0.1 -21.4 -21.9 11/26/2005 22:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 300 0 300 300 -21.9 0 -21.6 -21.9 11/26/2005 22:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 313 19 300 300 -22.1 0.1 -21.9 -22.3 11/26/2005 22:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0 6 300 300 -22.2 0 -22.1 -22.3 11/26/2005 23:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 26 9 300 300 -22.6 0.1 -22.3 -23 11/26/2005 23:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 38 5 300 300 -22.7 0.1 -22.5 -23 11/26/2005 23:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 82 38 300 300 -22.8 0.1 -22.5 -23 11/26/2005 23:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 150 0 300 300 -22.5 0.2 -22.1 -23 11/26/2005 23:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 169 18 300 300 -22.3 0 -22.1 -22.3 11/26/2005 23:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 189 1 300 300 -22.4 0 -22.3 -22.5 11/27/2005 00:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 190 0 300 300 -22.5 0 -22.3 -22.5 11/27/2005 00:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 190 0 300 300 -22.5 0 -22.5 -22.6 11/27/2005 00:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 190 0 300 300 -22.3 0 -22.1 -22.5 11/27/2005 00:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 190 0 300 300 -22.4 0.1 -22.1 -22.5 11/27/2005 00:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 145 79 300 300 -22.5 0 -22.3 -22.5 11/27/2005 00:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 37 5 300 300 -22.5 0 -22.3 -22.6 11/27/2005 01:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 52 5 300 300 -22.6 0.2 -21.9 -23 11/27/2005 01:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 51 4 300 300 -21.5 0.1 -21.4 -21.9 11/27/2005 01:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 37 4 300 300 -21.2 0.3 -20.9 -21.6 11/27/2005 01:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 1 300 300 -21.7 0.3 -20.9 -22.1 11/27/2005 01:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 43 8 300 300 -22.5 0.2 -21.9 -22.8 11/27/2005 01:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 46 5 300 300 -22.8 0 -22.6 -23 11/27/2005 02:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 31 9 300 300 -23 0.1 -22.6 -23.3 11/27/2005 02:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 22 3 300 300 -23.1 0.1 -23 -23.3 11/27/2005 02:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 40 5 300 300 -23 0 -23 -23.1 11/27/2005 02:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 45 3 300 300 -23.2 0.1 -23 -23.5 11/27/2005 02:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 58 5 300 300 -23.7 0.1 -23.3 -23.8 11/27/2005 02:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 42 2 300 300 -23.7 0 -23.7 -23.8 11/27/2005 03:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 43 2 300 300 -23.6 0 -23.5 -23.7 11/27/2005 03:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 44 3 300 300 -23.9 0.1 -23.7 -24 11/27/2005 03:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 50 5 300 300 -23.7 0.1 -23.5 -24 11/27/2005 03:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.7 0.4 46 4 300 300 -23.1 0.1 -23 -23.5 11/27/2005 03:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 53 5 300 300 -22.3 0.7 -20.9 -23 11/27/2005 03:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.7 0.4 44 6 300 300 -20.4 0.1 -20.2 -20.9 11/27/2005 04:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.7 0.4 40 3 300 300 -19.9 0.4 -19.1 -20.3 11/27/2005 04:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 38 2 300 300 -21.1 0.7 -19.6 -21.9 11/27/2005 04:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 36 0 300 300 -22.4 0.2 -21.8 -22.8 11/27/2005 04:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 35 0 300 300 -22.6 0 -22.5 -22.8 11/27/2005 04:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 35 0 300 300 -23 0.2 -22.6 -23.3 11/27/2005 04:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 35 0 300 300 -23.5 0.1 -23 -23.7 11/27/2005 05:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 35 0 300 300 -23.8 0 -23.7 -24 11/27/2005 05:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 35 0 300 300 -23.9 0.1 -23.7 -24 11/27/2005 05:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 35 0 300 300 -23.9 0.1 -23.7 -24.2 11/27/2005 05:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 35 0 300 300 -24.3 0.1 -24 -24.3 11/27/2005 05:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 35 0 300 300 -24.3 0.1 -24.2 -24.5 11/27/2005 05:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 35 0 300 300 -24.3 0.1 -24 -24.3 11/27/2005 06:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 35 1 300 300 -23.6 0.2 -23 -24.2 11/27/2005 06:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 324 39 300 300 -22.8 0.2 -22.5 -23.3 11/27/2005 06:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 300 0 300 300 -23.7 0.2 -23.1 -24 11/27/2005 06:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 300 0 300 300 -24.3 0.1 -23.8 -24.3 11/27/2005 06:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 300 0 300 300 -24.5 0.1 -24.3 -24.7 11/27/2005 06:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 300 0 300 300 -24.2 0.2 -23.7 -24.5 11/27/2005 07:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 300 0 300 300 -23.9 0 -23.7 -24.2 11/27/2005 07:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 315 19 300 300 -24.4 0.2 -24 -24.7 11/27/2005 07:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 334 8 300 300 -24.7 0 -24.3 -24.7 11/27/2005 07:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 318 0 300 300 -24.8 0 -24.7 -24.8 11/27/2005 07:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 356 32 300 300 -24.7 0 -24.7 -24.8 11/27/2005 07:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 66 7 300 300 -24.8 0.1 -24.5 -25.2 11/27/2005 08:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 66 3 300 300 -25.3 0.1 -25 -25.5 11/27/2005 08:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 61 9 300 300 -25.1 0.2 -24.7 -25.2 11/27/2005 08:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 52 4 300 300 -24.7 0.1 -24.3 -25 11/27/2005 08:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 50 0 300 300 -24.7 0.2 -24.2 -25 11/27/2005 08:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 28 21 300 300 -24.3 0.2 -24.2 -24.7 11/27/2005 08:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 303 22 300 300 -24.5 0.1 -24.2 -24.8 11/27/2005 09:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 244 0 300 300 -24.9 0 -24.7 -25.2 11/27/2005 09:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 244 0 300 300 -24.7 0 -24.5 -24.8 11/27/2005 09:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 271 58 300 300 -25 0.1 -24.7 -25.2 11/27/2005 09:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 41 0 300 300 -24.8 0.3 -24.2 -25.2 11/27/2005 09:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 33 1 300 300 -24.3 0.2 -24 -24.7 11/27/2005 09:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 32 0 300 300 -24.5 0.1 -24.2 -24.7 11/27/2005 10:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 32 0 300 300 -24.2 0 -24 -24.3 11/27/2005 10:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 32 0 300 300 -24.4 0.1 -24.2 -24.7 11/27/2005 10:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 31 1 300 300 -24.6 0.2 -24.2 -24.8 11/27/2005 10:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 31 0 300 300 -24.2 0.1 -24 -24.3 11/27/2005 10:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 33 6 300 300 -24.5 0.1 -24.2 -24.7 11/27/2005 10:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 70 2 300 300 -24.3 0.1 -24.2 -24.3 11/27/2005 11:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 65 5 300 300 -23.9 0.1 -23.7 -24.2 11/27/2005 11:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 55 3 300 300 -23 0.4 -21.9 -23.7 11/27/2005 11:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.7 0.4 46 1 300 300 -20.9 0.3 -20.3 -21.9 11/27/2005 11:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.7 0.4 46 1 300 300 -21 0.1 -20.7 -21.2 11/27/2005 11:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 47 1 300 300 -20 0.8 -18.7 -20.9 11/27/2005 11:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 46 0 300 300 -18.3 0.2 -17.8 -18.9 11/27/2005 12:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 47 0 300 300 -18 0.3 -17.4 -18.5 11/27/2005 12:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 47 0 300 300 -18 0.3 -17.4 -18.5 11/27/2005 12:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 47 0 300 300 -17.3 0.3 -16.7 -17.6 11/27/2005 12:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 47 0 300 300 -15.9 0.5 -15.3 -16.9 11/27/2005 12:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 47 0 300 300 -15.2 0.3 -14.8 -15.9 11/27/2005 12:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 46 0 300 300 -15.5 0.6 -14.6 -16.3 11/27/2005 13:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 46 0 300 300 -14.4 0.2 -14 -14.8 11/27/2005 13:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 46 0 300 300 -13.8 0 -13.6 -14.2 11/27/2005 13:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 47 0 300 300 -13.5 0.3 -12.8 -13.8 11/27/2005 13:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 47 0 300 300 -12.7 0.4 -11.8 -13.2 11/27/2005 13:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 47 0 300 300 -11.1 0.4 -10.4 -11.8 11/27/2005 13:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 47 0 300 300 -10.3 0.1 -9.7 -10.6 11/27/2005 14:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 46 0 300 300 -11.5 0.9 -10.4 -13.4 11/27/2005 14:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 46 0 300 300 -14.1 0.2 -13.4 -14.4 11/27/2005 14:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 46 0 300 300 -13.7 0.4 -13.2 -14.6 11/27/2005 14:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 47 0 300 300 -14.9 0.2 -14.4 -15.3 11/27/2005 14:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 47 0 300 300 -15.7 0.2 -15.1 -15.9 11/27/2005 14:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 47 0 300 300 -16.1 0.2 -15.9 -16.5 11/27/2005 15:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 46 0 300 300 -16.7 0.1 -16.5 -16.9 11/27/2005 15:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 46 0 300 300 -17 0 -16.7 -17.2 11/27/2005 15:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 47 0 300 300 -17.4 0 -17.1 -17.6 11/27/2005 15:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 47 0 300 300 -17.7 0.1 -17.4 -17.8 11/27/2005 15:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 47 0 300 300 -17.4 0 -17.2 -17.6 11/27/2005 15:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 47 0 300 300 -17.6 0 -17.4 -17.8 11/27/2005 16:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 47 0 300 300 -17.5 0 -17.2 -17.4 11/27/2005 16:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 47 0 300 300 -17.4 0 -17.2 -17.4 11/27/2005 16:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 47 0 300 300 -17.1 0.2 -16.7 -17.4 11/27/2005 16:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 47 0 300 300 -16.9 0.1 -16.5 -17.1 11/27/2005 16:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 46 0 300 300 -16.8 0.1 -16.5 -17.1 11/27/2005 16:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 47 0 300 300 -16.6 0.1 -16.3 -16.9 11/27/2005 17:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 47 0 300 300 -16.5 0.2 -16.3 -16.9 11/27/2005 17:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 47 0 300 300 -17.1 0.1 -16.9 -17.4 11/27/2005 17:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 47 0 300 300 -17 0.4 -16.3 -17.4 11/27/2005 17:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 47 0 300 300 -16.2 0 -15.9 -16.5 11/27/2005 17:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 47 0 300 300 -16.9 0.1 -16.5 -17.1 11/27/2005 17:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 46 0 300 300 -17.1 0.1 -17.1 -17.4 11/27/2005 18:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 46 0 300 300 -17.7 0.1 -17.2 -18 11/27/2005 18:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 46 0 300 300 -18.1 0.2 -17.8 -18.5 11/27/2005 18:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 46 0 300 300 -18.9 0.2 -18.5 -19.1 11/27/2005 18:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 46 0 300 300 -19.4 0.2 -19.1 -19.8 11/27/2005 18:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.7 0.4 46 0 300 300 -19.9 0 -19.8 -20.2 11/27/2005 18:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 46 0 300 300 -19.3 0.3 -18.7 -19.8 11/27/2005 19:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 46 0 300 300 -19.2 0.2 -18.5 -19.6 11/27/2005 19:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.7 0.4 46 0 300 300 -18.7 0.6 -17.6 -19.6 11/27/2005 19:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 46 0 300 300 -18.3 0.4 -17.8 -19.1 11/27/2005 19:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 47 0 300 300 -19.4 0.1 -18.9 -19.6 11/27/2005 19:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 47 0 300 300 -19.6 0.1 -19.3 -20 11/27/2005 19:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 47 0 300 300 -20.3 0.2 -19.8 -20.7 11/27/2005 20:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 47 0 300 300 -20.7 0 -20.5 -20.7 11/27/2005 20:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 47 0 300 300 -20.9 0.1 -20.5 -21.2 11/27/2005 20:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 47 0 300 300 -21.4 0 -21.1 -21.4 11/27/2005 20:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 47 0 300 300 -20.8 0.2 -20.3 -21.1 11/27/2005 20:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 47 0 300 300 -20.8 0.1 -20.5 -20.9 11/27/2005 20:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 46 0 300 300 -20.8 0 -20.7 -20.9 11/27/2005 21:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 46 0 300 300 -20.9 0.1 -20.7 -21.2 11/27/2005 21:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 46 0 300 300 -21.5 0.2 -21.1 -21.8 11/27/2005 21:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 46 0 300 300 -21.9 0 -21.6 -21.9 11/27/2005 21:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 47 0 300 300 -21.9 0 -21.8 -22.1 11/27/2005 21:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 47 0 300 300 -22.2 0 -21.9 -22.3 11/27/2005 21:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 47 0 300 300 -21.8 0.1 -21.6 -21.9 11/27/2005 22:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 47 0 300 300 -22.2 0.1 -21.8 -22.3 11/27/2005 22:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 47 0 300 300 -22.1 0.1 -21.9 -22.3 11/27/2005 22:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 47 0 300 300 -22.3 0.2 -21.9 -22.5 11/27/2005 22:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 47 0 300 300 -22.5 0 -22.5 -22.6 11/27/2005 22:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 47 0 300 300 -22.7 0 -22.5 -22.8 11/27/2005 22:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 47 0 300 300 -22.7 0 -22.5 -22.8 11/27/2005 23:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 47 0 300 300 -22.6 0.1 -22.5 -23 11/27/2005 23:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 47 0 300 300 -22.7 0.1 -22.3 -23 11/27/2005 23:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 47 0 300 300 -23.1 0 -23 -23.1 11/27/2005 23:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 47 0 300 300 -23 0 -23 -23.1 11/27/2005 23:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 47 0 300 300 -22.9 0 -22.8 -23 11/27/2005 23:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 47 0 300 300 -23 0 -22.8 -23.1 11/28/2005 00:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 47 0 300 300 -23.1 0 -23 -23.3 11/28/2005 00:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.7 0.4 47 0 300 300 -23.2 0.1 -23 -23.5 11/28/2005 00:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.7 0.4 48 1 300 300 -22.7 0.2 -22.5 -23 11/28/2005 00:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.7 0.4 50 0 300 300 -22.5 0.1 -22.1 -22.6 11/28/2005 00:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.7 0.4 51 0 300 300 -21.9 0.2 -21.4 -22.3 11/28/2005 00:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0.1 0.7 0.4 51 1 300 300 -21.1 0.2 -20.7 -21.6 11/28/2005 01:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0.1 0.7 0.4 52 3 300 300 -19.8 0.5 -19.1 -20.7 11/28/2005 01:10:00 0.4 0 0.7 0.4 0.4 0 0.4 0.4 0.4 0.1 0.7 0.4 46 6 34 300 -18.6 0.3 -18 -19.1 11/28/2005 01:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0.1 0.7 0.4 39 7 300 300 -17.6 0.3 -17.1 -18 11/28/2005 01:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0.1 0.7 0.4 40 7 300 300 -17 0 -17.1 -17.2 11/28/2005 01:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.7 0.4 39 5 300 300 -17 0 -16.9 -17.1 11/28/2005 01:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.7 0.4 36 5 300 300 -16.9 0 -16.7 -17.1 11/28/2005 02:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.7 0.4 37 5 300 300 -16.6 0.1 -16.3 -16.9 11/28/2005 02:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.7 0.4 29 7 300 300 -16.1 0.1 -15.9 -16.3 11/28/2005 02:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 23 7 300 300 -15.9 0 -15.9 -15.9 11/28/2005 02:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 13 5 300 300 -17 0.7 -15.9 -18.5 11/28/2005 02:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 4 11 300 300 -20.3 0.7 -18.5 -21.2 11/28/2005 02:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 340 0 300 300 -22 0.4 -21.1 -22.6 11/28/2005 03:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 347 11 300 300 -22.9 0.1 -22.5 -23 11/28/2005 03:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 2 1 300 300 -23.1 0.1 -23 -23.3 11/28/2005 03:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 342 10 300 300 -23.3 0 -23.1 -23.3 11/28/2005 03:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 336 0 300 300 -23.1 0 -23 -23.3 11/28/2005 03:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 336 0 300 300 -23.1 0 -23 -23.1 11/28/2005 03:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 336 0 300 300 -22.9 0.1 -22.8 -23.1 11/28/2005 04:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 336 0 300 300 -22.8 0.1 -22.5 -23 11/28/2005 04:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 336 0 300 300 -22.6 0 -22.5 -22.8 11/28/2005 04:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 336 0 300 300 -22.6 0.1 -22.5 -23 11/28/2005 04:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 336 0 300 300 -22.8 0.1 -22.5 -23 11/28/2005 04:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 336 0 300 300 -22.8 0.1 -22.5 -23 11/28/2005 04:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 336 0 300 300 -22.8 0.2 -22.5 -23 11/28/2005 05:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 336 0 300 300 -22.8 0.2 -22.5 -23 11/28/2005 05:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 330 6 300 300 -23 0 -23 -23.1 11/28/2005 05:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 324 0 300 300 -23.3 0 -23 -23.3 11/28/2005 05:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 324 0 300 300 -23.3 0.2 -23 -23.7 11/28/2005 05:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 324 0 300 300 -23.7 0.1 -23.3 -24 11/28/2005 05:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 324 0 300 300 -23.7 0 -23.7 -23.8 11/28/2005 06:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 324 0 300 300 -23.8 0.1 -23.7 -24.2 11/28/2005 06:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 324 0 300 300 -24.2 0 -23.8 -24.3 11/28/2005 06:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 339 35 300 300 -24 0.1 -23.8 -24.2 11/28/2005 06:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 50 5 300 300 -23.9 0.1 -23.7 -24.2 11/28/2005 06:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 45 2 300 300 -23.9 0.1 -23.7 -24 11/28/2005 06:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 47 0 300 300 -24 0 -23.8 -24.2 11/28/2005 07:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 47 0 300 300 -23.8 0 -23.7 -24 11/28/2005 07:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 39 4 300 300 -23.7 0 -23.7 -24 11/28/2005 07:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 52 5 300 300 -24 0.2 -23.5 -24.2 11/28/2005 07:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 58 1 300 300 -23.2 0.1 -23 -23.7 11/28/2005 07:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 59 0 300 300 -23.7 0.1 -23.1 -23.8 11/28/2005 07:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 58 1 300 300 -23.4 0.4 -22.6 -24 11/28/2005 08:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 56 0 300 300 -22.6 0 -22.5 -22.8 11/28/2005 08:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 55 0 300 300 -23.4 0.3 -22.6 -23.8 11/28/2005 08:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 55 0 300 300 -23.8 0 -23.7 -24 11/28/2005 08:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 56 0 300 300 -24.3 0.1 -23.8 -24.3 11/28/2005 08:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 56 0 300 300 -24 0.2 -23.7 -24.3 11/28/2005 08:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 56 0 300 300 -23.6 0 -23.7 -23.7 11/28/2005 09:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 65 33 300 300 -23.7 0.1 -23.7 -24 11/28/2005 09:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 205 0 300 300 -23.7 0.1 -23.3 -23.8 11/28/2005 09:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 206 0 300 300 -23.4 0.1 -23.1 -23.7 11/28/2005 09:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 206 0 300 300 -23.9 0.2 -23.7 -24.2 11/28/2005 09:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 207 0 300 300 -24.1 0 -23.8 -24.2 11/28/2005 09:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 207 0 300 300 -23.9 0.1 -23.7 -24 11/28/2005 10:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 207 0 300 300 -23.4 0.1 -23.1 -23.7 11/28/2005 10:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 207 0 300 300 -23.3 0.2 -23 -23.7 11/28/2005 10:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 251 23 300 300 -23.6 0.1 -23.3 -23.7 11/28/2005 10:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 265 1 300 300 -23.1 0 -23 -23.3 11/28/2005 10:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 268 1 300 300 -23.1 0 -23 -23.3 11/28/2005 10:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 268 0 300 300 -23.4 0.1 -23 -23.5 11/28/2005 11:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 268 0 300 300 -23.4 0 -23.1 -23.5 11/28/2005 11:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 268 0 300 300 -23.3 0 -23 -23.5 11/28/2005 11:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 269 0 300 300 -22.8 0.1 -22.6 -23.1 11/28/2005 11:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 269 0 300 300 -22.2 0.4 -21.2 -23 11/28/2005 11:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 269 0 300 300 -20.4 0.4 -19.8 -21.2 11/28/2005 11:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 269 0 300 300 -19.1 0.3 -18.5 -19.8 11/28/2005 12:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 268 0 300 300 -18.4 0.4 -17.4 -18.7 11/28/2005 12:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 268 0 300 300 -16.5 0.5 -15.5 -17.4 11/28/2005 12:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 269 0 300 300 -15.3 0.1 -15 -15.5 11/28/2005 12:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 269 0 300 300 -15 0 -14.6 -15.1 11/28/2005 12:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 269 0 300 300 -14.1 0.3 -13.4 -14.8 11/28/2005 12:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 269 0 300 300 -12.8 0.3 -12.2 -13.4 11/28/2005 13:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 269 0 300 300 -12 0.1 -11.8 -12.2 11/28/2005 13:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 269 0 300 300 -12 0.3 -11.4 -12.4 11/28/2005 13:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 269 0 300 300 -11.9 0.3 -11.4 -12.2 11/28/2005 13:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 269 0 300 300 -11.9 0 -11.8 -12.2 11/28/2005 13:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 269 0 300 300 -11.9 0 -11.8 -12 11/28/2005 13:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 269 0 300 300 -12.6 0.4 -12 -13.6 11/28/2005 14:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 269 0 300 300 -14.7 0.7 -13.6 -15.9 11/28/2005 14:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 269 0 300 300 -17.1 0.4 -15.9 -17.4 11/28/2005 14:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 269 0 300 300 -17.5 0.3 -17.1 -18 11/28/2005 14:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 269 0 300 300 -17.9 0.3 -17.4 -18.2 11/28/2005 14:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 269 0 300 300 -17.8 0.2 -17.4 -18 11/28/2005 14:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 269 0 300 300 -17.9 0.2 -17.4 -18.2 11/28/2005 15:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 269 0 300 300 -17.6 0.3 -17.1 -18 11/28/2005 15:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 269 0 300 300 -18.4 0.2 -18 -18.9 11/28/2005 15:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 269 0 300 300 -19.2 0.2 -18.7 -19.6 11/28/2005 15:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 269 0 300 300 -19.9 0.2 -19.6 -20.3 11/28/2005 15:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 269 0 300 300 -20.4 0.1 -20.2 -20.5 11/28/2005 15:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 270 0 300 300 -20.7 0.1 -20.3 -20.9 11/28/2005 16:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 271 1 300 300 -21 0.1 -20.7 -21.2 11/28/2005 16:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 273 0 300 300 -21.1 0 -20.9 -21.2 11/28/2005 16:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 273 0 300 300 -21.4 0.1 -21.1 -21.6 11/28/2005 16:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 273 0 300 300 -21.5 0.1 -21.4 -21.8 11/28/2005 16:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 273 0 300 300 -21.6 0.1 -21.4 -21.8 11/28/2005 16:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 273 0 300 300 -21.7 0 -21.6 -21.8 11/28/2005 17:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 273 0 300 300 -21.5 0 -21.4 -21.8 11/28/2005 17:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 273 0 300 300 -21.9 0 -21.6 -22.3 11/28/2005 17:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 273 0 300 300 -22.2 0 -21.9 -22.3 11/28/2005 17:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 273 0 300 300 -22.3 0.1 -21.9 -22.5 11/28/2005 17:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 273 0 300 300 -22.6 0 -22.5 -22.8 11/28/2005 17:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 273 0 300 300 -22.7 0 -22.5 -23 11/28/2005 18:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 273 0 300 300 -23 0.1 -22.8 -23.1 11/28/2005 18:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 273 0 300 300 -23 0.1 -23 -23.1 11/28/2005 18:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 273 0 300 300 -23.3 0.1 -23 -23.5 11/28/2005 18:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 273 0 300 300 -23.1 0.2 -23 -23.5 11/28/2005 18:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 273 0 300 300 -22.5 0.2 -22.1 -23 11/28/2005 18:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 273 0 300 300 -22.2 0.1 -21.9 -22.5 11/28/2005 19:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 273 0 300 300 -22.5 0 -22.3 -22.8 11/28/2005 19:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 273 0 300 300 -23.1 0.2 -22.5 -23.3 11/28/2005 19:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 273 0 300 300 -23.3 0 -23 -23.3 11/28/2005 19:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 273 0 300 300 -23.6 0.2 -23.1 -23.8 11/28/2005 19:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 273 0 300 300 -23.7 0.1 -23.7 -23.8 11/28/2005 19:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 273 0 300 300 -23.5 0.1 -23.1 -23.7 11/28/2005 20:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 272 0 300 300 -22.5 0.3 -21.9 -23.1 11/28/2005 20:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 273 0 300 300 -22.2 0.3 -21.8 -22.8 11/28/2005 20:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 273 0 300 300 -22.8 0.1 -22.6 -23 11/28/2005 20:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 273 0 300 300 -22.8 0 -22.5 -23 11/28/2005 20:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 273 0 300 300 -22.9 0.1 -22.6 -23 11/28/2005 20:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 273 0 300 300 -23.1 0 -23 -23.1 11/28/2005 21:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 273 0 300 300 -22.9 0.1 -22.6 -23.1 11/28/2005 21:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 273 0 300 300 -22.6 0.1 -22.3 -23 11/28/2005 21:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 274 0 300 300 -22.5 0 -22.1 -22.5 11/28/2005 21:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 274 0 300 300 -22.2 0 -21.9 -22.3 11/28/2005 21:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 274 0 300 300 -22.1 0.1 -21.9 -22.3 11/28/2005 21:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 274 0 300 300 -22 0 -21.9 -22.3 11/28/2005 22:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 274 0 300 300 -21.9 0 -21.6 -21.9 11/28/2005 22:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 274 0 300 300 -22.1 0.1 -21.9 -22.5 11/28/2005 22:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 274 0 300 300 -22.7 0.2 -22.3 -23 11/28/2005 22:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 274 0 300 300 -22.8 0.1 -22.5 -23 11/28/2005 22:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 274 0 300 300 -22.7 0.1 -22.5 -23 11/28/2005 22:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 274 0 300 300 -22.9 0 -22.8 -23 11/28/2005 23:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 274 0 300 300 -22.7 0.1 -22.5 -23 11/28/2005 23:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 274 0 300 300 -22.8 0.1 -22.5 -23.1 11/28/2005 23:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 274 0 300 300 -23.2 0.1 -23 -23.7 11/28/2005 23:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 274 0 300 300 -23.6 0 -23.3 -23.7 11/28/2005 23:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 274 0 300 300 -23.7 0 -23.7 -23.8 11/28/2005 23:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 274 0 300 300 -23.7 0 -23.3 -23.7 11/29/2005 00:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 274 0 300 300 -23 0.1 -23 -23.5 11/29/2005 00:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 274 0 300 300 -23.4 0.2 -23 -23.7 11/29/2005 00:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 274 0 300 300 -23.6 0 -23.1 -23.7 11/29/2005 00:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 274 0 300 300 -23.1 0 -23 -23.1 11/29/2005 00:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 274 0 300 300 -23.3 0.3 -22.8 -23.7 11/29/2005 00:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 274 0 300 300 -23.9 0.1 -23.7 -24.2 11/29/2005 01:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 274 0 300 300 -24.1 0 -23.8 -24.2 11/29/2005 01:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 274 0 300 300 -24.2 0 -24 -24.3 11/29/2005 01:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 275 0 300 300 -23.7 0.3 -23.3 -24.2 11/29/2005 01:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 275 0 300 300 -23.4 0.1 -23 -23.7 11/29/2005 01:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 275 0 300 300 -23.1 0.2 -22.8 -23.7 11/29/2005 01:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 275 0 300 300 -23.3 0.2 -23 -23.7 11/29/2005 02:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 275 0 300 300 -22.8 0.2 -22.5 -23.1 11/29/2005 02:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 275 0 300 300 -22.4 0.2 -22.1 -22.8 11/29/2005 02:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 275 0 300 300 -22.2 0.1 -21.9 -22.3 11/29/2005 02:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 275 0 300 300 -22.2 0.2 -21.9 -22.5 11/29/2005 02:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 275 0 300 300 -22.8 0.1 -22.5 -23 11/29/2005 02:50:00 0.4 0 0.7 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 155 112 59 300 -22.8 0.1 -22.6 -23 11/29/2005 03:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 76 23 300 300 -22.5 0.1 -22.3 -22.6 11/29/2005 03:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 47 2 300 300 -22.4 0 -22.3 -22.5 11/29/2005 03:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 44 4 300 300 -22.4 0 -22.3 -22.5 11/29/2005 03:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 37 0 300 300 -22.1 0 -21.9 -22.3 11/29/2005 03:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 37 0 300 300 -22 0.1 -21.8 -22.3 11/29/2005 03:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 2 300 300 -22.3 0.1 -22.1 -22.5 11/29/2005 04:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 32 2 300 300 -22.1 0.2 -21.8 -22.3 11/29/2005 04:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 27 0 300 300 -22 0 -21.8 -22.1 11/29/2005 04:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 75 41 300 300 -22.2 0.1 -21.9 -22.5 11/29/2005 04:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 191 45 300 300 -22.4 0.1 -22.3 -22.5 11/29/2005 04:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 159 30 300 300 -22.6 0 -22.5 -22.8 11/29/2005 04:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 113 18 300 300 -23 0 -22.6 -23.1 11/29/2005 05:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 79 6 300 300 -22.6 0.2 -22.3 -23 11/29/2005 05:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 56 4 300 300 -22.2 0.1 -21.9 -22.3 11/29/2005 05:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 348 36 300 300 -21.8 0.1 -21.6 -21.9 11/29/2005 05:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 305 41 300 300 -21.8 0.1 -21.6 -21.9 11/29/2005 05:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 200 0 300 300 -22 0 -21.8 -22.1 11/29/2005 05:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 193 30 300 300 -22.3 0.1 -21.9 -22.5 11/29/2005 06:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 41 5 300 300 -22.5 0 -22.3 -22.8 11/29/2005 06:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 48 1 300 300 -22.7 0.2 -22.1 -23 11/29/2005 06:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.7 0.4 74 8 300 300 -22.2 0.1 -21.9 -22.5 11/29/2005 06:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 69 5 300 300 -21.9 0.4 -21.4 -22.5 11/29/2005 06:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 62 2 300 300 -21.6 0 -21.4 -21.8 11/29/2005 06:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 78 6 300 300 -22.1 0.3 -21.6 -22.5 11/29/2005 07:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 86 5 300 300 -22.3 0 -22.1 -22.5 11/29/2005 07:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 112 12 300 300 -21.2 0.4 -20.7 -22.1 11/29/2005 07:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 101 15 300 300 -22 0.3 -21.2 -22.3 11/29/2005 07:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 70 8 300 300 -22 0.6 -20.5 -22.5 11/29/2005 07:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 65 0 300 300 -20.5 0.4 -20 -21.4 11/29/2005 07:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 65 0 300 300 -22.2 0.4 -21.2 -22.6 11/29/2005 08:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 62 6 300 300 -23 0.2 -22.6 -23.3 11/29/2005 08:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 39 1 300 300 -23.1 0 -23 -23.1 11/29/2005 08:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 39 0 300 300 -23.1 0.2 -23 -23.5 11/29/2005 08:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 39 0 300 300 -23.6 0 -23.3 -23.7 11/29/2005 08:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 39 0 300 300 -23.9 0 -23.7 -24 11/29/2005 08:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 39 0 300 300 -24 0.1 -23.7 -24.2 11/29/2005 09:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 39 0 300 300 -23.7 0 -23.5 -23.8 11/29/2005 09:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 39 0 300 300 -23.6 0 -23.3 -23.7 11/29/2005 09:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 39 0 300 300 -23.9 0.1 -23.7 -24.2 11/29/2005 09:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 39 0 300 300 -23.7 0.2 -23.3 -24.2 11/29/2005 09:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 47 12 300 300 -22.9 0.2 -22.5 -23.3 11/29/2005 09:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 66 1 300 300 -21.8 0.3 -21.1 -22.5 11/29/2005 10:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 65 0 300 300 -21.5 0.3 -20.9 -22.1 11/29/2005 10:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 65 0 300 300 -22.5 0.2 -21.9 -22.8 11/29/2005 10:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 65 0 300 300 -22.8 0.1 -22.6 -23 11/29/2005 10:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 66 0 300 300 -23.1 0 -23 -23.3 11/29/2005 10:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 65 0 300 300 -23 0 -22.8 -23 11/29/2005 10:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 65 0 300 300 -23 0 -22.8 -23 11/29/2005 11:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 65 0 300 300 -22.7 0.2 -22.3 -23 11/29/2005 11:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 65 0 300 300 -22.6 0 -22.5 -23 11/29/2005 11:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 65 0 300 300 -22.9 0.1 -22.6 -23 11/29/2005 11:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 65 0 300 300 -22.7 0.2 -22.3 -23 11/29/2005 11:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 65 0 300 300 -21.2 0.5 -20.5 -22.3 11/29/2005 11:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 65 0 300 300 -20.5 0.2 -20 -20.7 11/29/2005 12:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 65 0 300 300 -19.6 0.2 -19.3 -20 11/29/2005 12:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 65 0 300 300 -18.7 0.3 -18.2 -19.4 11/29/2005 12:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 65 0 300 300 -17.3 0.5 -16.5 -18.2 11/29/2005 12:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 65 0 300 300 -16.2 0.2 -15.9 -16.5 11/29/2005 12:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 65 0 300 300 -14.9 0.5 -14.2 -15.9 11/29/2005 12:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 66 0 300 300 -15 0.1 -14.6 -15.1 11/29/2005 13:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 69 6 300 300 -14.4 0.3 -13.8 -15 11/29/2005 13:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 64 4 300 300 -13.7 0 -13.4 -13.8 11/29/2005 13:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 64 5 300 300 -13.3 0.1 -12.8 -13.6 11/29/2005 13:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 81 5 300 300 -12.4 0.3 -11.8 -13 11/29/2005 13:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 75 0 300 300 -11.5 0.4 -10.6 -12 11/29/2005 13:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 75 0 300 300 -10.8 0.1 -10.4 -11 11/29/2005 14:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 75 0 300 300 -12.6 0.9 -11 -14 11/29/2005 14:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 75 0 300 300 -14.9 0.4 -14 -15.3 11/29/2005 14:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 106 64 300 300 -15.7 0.3 -15.1 -16.3 11/29/2005 14:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 239 0 300 300 -16.7 0.2 -16.3 -17.1 11/29/2005 14:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 239 0 300 300 -17.2 0.2 -16.7 -17.4 11/29/2005 14:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 239 0 300 300 -17.7 0.1 -17.4 -17.8 11/29/2005 15:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 321 51 300 300 -17.6 0 -17.4 -17.8 11/29/2005 15:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 1 12 300 300 -17.6 0 -17.4 -17.6 11/29/2005 15:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 14 2 300 300 -17.6 0 -17.4 -18 11/29/2005 15:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 352 12 300 300 -18.3 0.2 -17.8 -18.5 11/29/2005 15:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 327 0 300 300 -19 0.2 -18.5 -19.4 11/29/2005 15:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 327 0 300 300 -19.7 0.1 -19.3 -19.8 11/29/2005 16:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 331 3 300 300 -19.7 0.1 -19.1 -20.3 11/29/2005 16:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 337 12 300 300 -19.1 0.1 -18.9 -19.4 11/29/2005 16:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 346 0 300 300 -19.7 0.2 -19.3 -20 11/29/2005 16:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 346 0 300 300 -20.3 0 -19.8 -20.3 11/29/2005 16:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 352 6 300 300 -20.5 0.2 -20.3 -20.9 11/29/2005 16:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 359 0 300 300 -20.9 0 -20.7 -21.1 11/29/2005 17:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 31 9 300 300 -21 0.1 -20.7 -21.2 11/29/2005 17:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 38 3 300 300 -20.9 0.3 -20.3 -21.2 11/29/2005 17:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 38 3 300 300 -20.7 0 -20.3 -20.9 11/29/2005 17:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.7 0.4 46 2 300 300 -20.8 0.2 -20.3 -21.1 11/29/2005 17:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 40 3 300 300 -21.2 0.1 -20.9 -21.4 11/29/2005 17:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 48 2 300 300 -21.1 0.1 -20.9 -21.4 11/29/2005 18:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 48 0 300 300 -21.3 0.2 -20.9 -21.6 11/29/2005 18:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 71 21 300 300 -21.3 0 -21.1 -21.6 11/29/2005 18:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 66 7 300 300 -21.8 0.2 -21.4 -22.1 11/29/2005 18:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 62 0 300 300 -22 0 -21.9 -22.3 11/29/2005 18:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 62 1 300 300 -22 0.1 -21.6 -22.3 11/29/2005 18:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 55 4 300 300 -21.8 0.3 -20.9 -21.9 11/29/2005 19:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 52 1 300 300 -21.3 0.2 -20.9 -21.9 11/29/2005 19:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 43 6 300 300 -22.3 0.2 -21.8 -22.5 11/29/2005 19:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 41 7 300 300 -22.8 0.2 -22.5 -23 11/29/2005 19:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 39 1 300 300 -22.9 0 -22.8 -23 11/29/2005 19:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 39 0 300 300 -23.1 0 -23 -23.3 11/29/2005 19:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 38 1 300 300 -23.4 0.1 -23.1 -23.7 11/29/2005 20:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 1 300 300 -23.7 0 -23.5 -23.7 11/29/2005 20:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 30 1 300 300 -23.6 0 -23.5 -23.7 11/29/2005 20:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 39 2 300 300 -23.3 0.1 -23 -23.7 11/29/2005 20:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 3 300 300 -23 0.1 -22.8 -23.1 11/29/2005 20:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 31 2 300 300 -22.8 0.2 -22.3 -23 11/29/2005 20:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 45 17 300 300 -22.5 0.2 -22.1 -23 11/29/2005 21:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 68 9 300 300 -21.8 0.2 -21.4 -22.1 11/29/2005 21:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 65 5 300 300 -21.2 0.2 -20.9 -21.6 11/29/2005 21:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 60 4 300 300 -20.9 0.4 -20 -21.2 11/29/2005 21:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 63 4 300 300 -20.4 0.3 -20 -20.9 11/29/2005 21:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 75 7 300 300 -21.1 0.5 -20.3 -21.9 11/29/2005 21:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 72 9 300 300 -21.8 0.2 -21.6 -22.3 11/29/2005 22:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 50 9 300 300 -22.2 0.3 -21.6 -22.5 11/29/2005 22:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 41 0 300 300 -22.8 0.2 -22.5 -23.1 11/29/2005 22:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 40 2 300 300 -23.8 0.3 -23 -24.3 11/29/2005 22:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 28 6 300 300 -24.5 0.1 -24.2 -24.8 11/29/2005 22:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 27 10 300 300 -23.9 0.2 -23.5 -24.3 11/29/2005 22:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 2 300 300 -23.8 0.2 -23.3 -24.2 11/29/2005 23:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 32 1 300 300 -24 0 -23.8 -24.2 11/29/2005 23:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 29 0 300 300 -24.4 0.1 -24.2 -24.7 11/29/2005 23:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 29 0 300 300 -24.7 0 -24.3 -24.7 11/29/2005 23:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 30 0 300 300 -24.5 0.2 -24.2 -24.7 11/29/2005 23:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 30 0 300 300 -24.7 0 -24.5 -24.7 11/29/2005 23:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 30 0 300 300 -24.4 0.1 -24.2 -24.7 11/30/2005 00:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 30 0 300 300 -24.1 0.1 -23.7 -24.2 11/30/2005 00:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 30 0 300 300 -24 0.1 -23.7 -24.2 11/30/2005 00:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 288 86 300 300 -24.1 0 -23.7 -24.3 11/30/2005 00:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 260 72 300 300 -24.3 0.1 -24.2 -24.3 11/30/2005 00:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 31 1 300 300 -23.9 0.2 -23.7 -24.2 11/30/2005 00:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 35 3 300 300 -23.5 0.2 -23 -23.7 11/30/2005 01:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 1 300 300 -23.1 0.2 -22.8 -23.3 11/30/2005 01:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 24 6 300 300 -22.8 0.3 -22.5 -23.3 11/30/2005 01:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 29 0 300 300 -22.6 0.1 -22.5 -23 11/30/2005 01:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 30 1 300 300 -22.5 0 -22.3 -22.6 11/30/2005 01:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 39 5 300 300 -22.5 0 -22.5 -22.6 11/30/2005 01:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 51 6 300 300 -22.8 0.1 -22.6 -23 11/30/2005 02:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 42 0 300 300 -22.7 0.3 -22.3 -23 11/30/2005 02:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 42 1 300 300 -22.4 0.1 -22.3 -22.5 11/30/2005 02:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 40 0 300 300 -22.3 0 -22.3 -22.5 11/30/2005 02:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 40 0 300 300 -22.3 0.1 -22.1 -22.5 11/30/2005 02:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 40 0 300 300 -22.4 0 -22.3 -22.5 11/30/2005 02:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 41 1 300 300 -22.7 0.1 -22.5 -23 11/30/2005 03:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 45 2 300 300 -22.9 0 -22.8 -23 11/30/2005 03:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 40 0 300 300 -23 0 -22.8 -23.1 11/30/2005 03:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 43 5 300 300 -22.7 0.1 -22.5 -23 11/30/2005 03:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 49 0 300 300 -22.7 0 -22.5 -23 11/30/2005 03:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 43 4 300 300 -22.7 0.1 -22.5 -23 11/30/2005 03:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 39 3 300 300 -22.5 0 -22.5 -22.6 11/30/2005 04:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 41 2 300 300 -22 0.2 -21.6 -22.5 11/30/2005 04:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 40 2 300 300 -21.8 0.1 -21.6 -21.9 11/30/2005 04:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 39 2 300 300 -21.9 0 -21.6 -22.1 11/30/2005 04:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 30 4 300 300 -21.5 0.1 -21.1 -21.8 11/30/2005 04:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 29 4 300 300 -21.5 0.4 -20.9 -22.3 11/30/2005 04:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 26 5 300 300 -22.7 0.1 -22.3 -23 11/30/2005 05:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 26 3 300 300 -22.6 0 -22.5 -22.8 11/30/2005 05:10:00 0.4 0 0.7 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 29 2 28 300 -22.5 0 -22.3 -22.5 11/30/2005 05:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 28 3 300 300 -21.9 0.5 -20.9 -22.5 11/30/2005 05:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 26 3 300 300 -20.9 0.5 -19.8 -21.4 11/30/2005 05:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 22 3 300 300 -18.8 0.4 -18.2 -19.8 11/30/2005 05:50:00 0.4 0 0.4 0.4 0.4 0 0.7 0.4 0.4 0 0.4 0.4 16 4 300 300 -18 0.2 -17.8 -18.4 11/30/2005 06:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.7 0.4 14 5 300 300 -17.6 0 -17.4 -17.8 11/30/2005 06:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 6 5 300 300 -18.7 0.5 -17.8 -19.8 11/30/2005 06:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 14 6 300 300 -20 0.2 -19.6 -20.3 11/30/2005 06:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 23 4 300 300 -20.8 0.7 -19.4 -21.8 11/30/2005 06:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 15 4 300 300 -22.3 0.2 -21.8 -22.5 11/30/2005 06:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 14 4 300 300 -22.4 0 -22.3 -22.5 11/30/2005 07:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 32 6 300 300 -22.9 0.3 -22.5 -23.3 11/30/2005 07:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 33 3 300 300 -23.5 0 -23.1 -23.7 11/30/2005 07:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 44 1 300 300 -23.8 0.1 -23.7 -24 11/30/2005 07:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 35 9 300 300 -23.9 0 -23.7 -24 11/30/2005 07:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 37 4 300 300 -24.1 0 -23.8 -24.3 11/30/2005 07:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 30 5 300 300 -24 0.2 -23.5 -24.2 11/30/2005 08:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 3 300 300 -23.3 0.1 -23 -23.7 11/30/2005 08:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 29 2 300 300 -23.2 0 -23 -23.3 11/30/2005 08:20:00 0.4 0 0.4 0.4 0.4 0 0.7 0.4 0.4 0 0.4 0.4 27 3 300 300 -23.1 0.1 -23 -23.3 11/30/2005 08:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 32 3 300 300 -23.7 0.2 -23 -23.8 11/30/2005 08:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 31 3 300 300 -22.9 0.3 -22.5 -23.7 11/30/2005 08:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 27 4 300 300 -22.9 0.1 -22.5 -23.1 11/30/2005 09:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 19 3 300 300 -22.5 0 -22.3 -22.5 11/30/2005 09:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 17 3 300 300 -22.5 0 -22.3 -22.5 11/30/2005 09:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 6 3 300 300 -21.3 0.3 -20.9 -22.3 11/30/2005 09:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 13 4 300 300 -22.1 0.4 -21.4 -22.5 11/30/2005 09:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 18 7 300 300 -22.2 0.2 -21.9 -22.6 11/30/2005 09:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 27 0 300 300 -22.5 0.3 -21.8 -23 11/30/2005 10:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 27 0 300 300 -22.1 0.1 -21.6 -22.3 11/30/2005 10:10:00 0.4 0 0.4 0.4 0.4 0 0.7 0.4 0.4 0 0.4 0.4 317 35 300 300 -21.9 0.2 -21.6 -22.3 11/30/2005 10:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 287 12 300 300 -21.9 0.1 -21.6 -22.3 11/30/2005 10:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 271 0 300 300 -22.3 0 -21.9 -22.3 11/30/2005 10:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 271 0 300 300 -22.5 0.1 -22.3 -22.8 11/30/2005 10:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 271 0 300 300 -22.5 0 -22.5 -22.6 11/30/2005 11:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 271 0 300 300 -22.7 0 -22.5 -23 11/30/2005 11:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 271 0 300 300 -22.6 0.1 -22.3 -23 11/30/2005 11:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 271 0 300 300 -22.4 0.1 -22.1 -22.5 11/30/2005 11:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 271 0 300 300 -22.3 0.1 -22.1 -22.5 11/30/2005 11:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 271 0 300 300 -21.8 0.2 -21.4 -22.3 11/30/2005 11:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 271 0 300 300 -21.3 0 -21.1 -21.4 11/30/2005 12:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 271 0 300 300 -21.3 0.1 -21.1 -21.4 11/30/2005 12:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 271 0 300 300 -21 0.1 -20.3 -21.2 11/30/2005 12:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 271 0 300 300 -20.2 0.1 -20 -20.3 11/30/2005 12:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 271 0 300 300 -20.4 0.1 -20.2 -20.7 11/30/2005 12:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 271 0 300 300 -20.4 0.1 -20.2 -20.5 11/30/2005 12:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 271 0 300 300 -20.2 0.1 -20 -20.3 11/30/2005 13:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 271 0 300 300 -19.9 0.2 -19.4 -20.3 11/30/2005 13:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 286 35 300 300 -19.3 0.2 -18.9 -19.6 11/30/2005 13:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 8 0 300 300 -18.5 0.3 -17.8 -19.1 11/30/2005 13:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 8 0 300 300 -17.4 0.2 -16.9 -17.8 11/30/2005 13:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 8 0 300 300 -17 0 -16.7 -17.1 11/30/2005 13:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 34 12 300 300 -16.8 0 -16.5 -17.1 11/30/2005 14:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 39 0 300 300 -17.3 0.2 -16.9 -17.4 11/30/2005 14:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 134 102 300 300 -17 0.2 -16.5 -17.4 11/30/2005 14:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 291 27 300 300 -16.4 0 -16.3 -16.7 11/30/2005 14:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 10 11 300 300 -16.1 0.3 -15.5 -16.5 11/30/2005 14:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 35 7 300 300 -16.2 0.2 -15.5 -16.5 11/30/2005 14:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 62 10 300 300 -16.4 0.1 -16.1 -16.5 11/30/2005 15:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 69 0 300 300 -16.5 0 -16.3 -16.7 11/30/2005 15:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 69 0 300 300 -16.8 0.1 -16.5 -17.1 11/30/2005 15:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 66 5 300 300 -17.1 0 -17.1 -17.4 11/30/2005 15:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 59 0 300 300 -17.7 0.2 -17.2 -18 11/30/2005 15:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 59 0 300 300 -18 0 -18 -18.2 11/30/2005 15:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 59 0 300 300 -18.5 0.1 -18.2 -18.5 11/30/2005 16:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 306 27 300 300 -18.5 0 -18.5 -18.5 11/30/2005 16:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 282 7 300 300 -18.9 0.1 -18.5 -19.1 11/30/2005 16:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 351 21 300 300 -19.2 0.1 -18.9 -19.6 11/30/2005 16:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 23 2 300 300 -19.7 0 -19.3 -19.8 11/30/2005 16:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 25 0 300 300 -20 0.2 -19.8 -20.3 11/30/2005 16:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 25 0 300 300 -20.3 0 -20.3 -20.3 11/30/2005 17:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 25 0 300 300 -20.5 0 -20.3 -20.7 11/30/2005 17:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 25 0 300 300 -20.5 0 -20.3 -20.7 11/30/2005 17:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 24 3 300 300 -20.7 0.1 -20.3 -20.7 11/30/2005 17:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 14 0 300 300 -20.6 0.1 -20.3 -20.9 11/30/2005 17:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 23 4 300 300 -20.8 0.1 -20.3 -21.1 11/30/2005 17:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 26 3 300 300 -21 0.1 -20.5 -21.2 11/30/2005 18:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 25 5 300 300 -20.9 0.3 -20.5 -21.4 11/30/2005 18:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 31 1 300 300 -21.6 0 -21.4 -21.6 11/30/2005 18:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 37 2 300 300 -21.5 0.1 -21.4 -21.6 11/30/2005 18:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 39 0 300 300 -21.5 0 -21.4 -21.6 11/30/2005 18:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 39 0 300 300 -21.4 0.2 -21.1 -21.8 11/30/2005 18:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 47 6 300 300 -21.2 0 -21.1 -21.2 11/30/2005 19:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 52 0 300 300 -21.4 0 -21.1 -21.4 11/30/2005 19:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 3 43 300 300 -21.3 0 -21.1 -21.4 11/30/2005 19:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 7 35 300 300 -21.1 0 -20.9 -21.2 11/30/2005 19:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 50 7 300 300 -21.3 0 -21.1 -21.4 11/30/2005 19:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 64 7 300 300 -21.1 0.1 -20.9 -21.4 11/30/2005 19:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 80 0 300 300 -21 0.1 -20.7 -21.1 11/30/2005 20:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 38 35 300 300 -20.7 0.1 -20.3 -21.1 11/30/2005 20:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 28 0 300 300 -21.3 0.2 -20.9 -21.6 11/30/2005 20:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 37 7 300 300 -21 0.2 -20.9 -21.4 11/30/2005 20:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 50 0 300 300 -21.5 0.1 -21.2 -21.8 11/30/2005 20:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 54 5 300 300 -21.3 0.1 -20.9 -21.4 11/30/2005 20:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 25 17 300 300 -20.7 0.2 -20.3 -21.1 11/30/2005 21:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 15 0 300 300 -20.7 0.1 -20.3 -20.9 11/30/2005 21:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 15 0 300 300 -20.6 0.1 -20.3 -20.9 11/30/2005 21:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 24 15 300 300 -20.3 0 -20.2 -20.3 11/30/2005 21:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 63 5 300 300 -20.1 0 -20 -20.3 11/30/2005 21:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 67 2 300 300 -20.1 0 -20 -20.3 11/30/2005 21:50:00 0.4 0 0.4 0.4 0.4 0.2 1.5 0.4 0.4 0 0.4 0.4 53 12 300 300 -19.8 0.2 -19.4 -20.2 11/30/2005 22:00:00 0.4 0 0.4 0.4 0.5 0.3 1.5 0.4 0.4 0 0.4 0.4 61 5 300 300 -19.5 0 -19.3 -19.6 11/30/2005 22:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 64 0 300 300 -19.3 0 -19.1 -19.4 11/30/2005 22:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 57 22 300 300 -19.1 0.1 -18.7 -19.1 11/30/2005 22:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 338 0 300 300 -18.8 0 -18.5 -18.9 11/30/2005 22:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 321 27 300 300 -18.9 0 -18.7 -19.1 11/30/2005 22:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 276 0 300 300 -18.9 0 -18.7 -19.1 11/30/2005 23:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 276 0 300 300 -18.9 0 -18.5 -19.1 11/30/2005 23:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 269 8 300 300 -18.5 0.1 -18.2 -18.7 11/30/2005 23:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 259 0 300 300 -18.1 0 -18 -18.4 11/30/2005 23:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 268 15 300 300 -17.8 0 -17.4 -18 11/30/2005 23:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 284 6 300 300 -17.4 0.2 -17.1 -17.6 11/30/2005 23:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 281 2 300 300 -16.8 0 -16.5 -17.1 12/01/2005 00:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 276 11 300 300 -16.7 0 -16.5 -16.9 12/01/2005 00:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 255 0 300 300 -16.5 0 -16.5 -16.7 12/01/2005 00:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 255 0 300 300 -16.4 0 -16.5 -16.5 12/01/2005 00:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 267 7 300 300 -16.7 0.2 -16.5 -17.1 12/01/2005 00:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 261 2 300 300 -16.9 0 -16.9 -17.1 12/01/2005 00:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 313 23 300 300 -17.1 0 -16.9 -17.1 12/01/2005 01:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 327 5 300 300 -16.8 0.1 -16.5 -17.1 12/01/2005 01:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 322 4 300 300 -16.7 0 -16.5 -16.9 12/01/2005 01:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 339 35 300 300 -16.7 0 -16.5 -16.9 12/01/2005 01:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 297 56 300 300 -16.6 0 -16.5 -16.7 12/01/2005 01:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 222 0 300 300 -16.6 0 -16.5 -16.7 12/01/2005 01:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 222 0 300 300 -16.6 0 -16.5 -16.7 12/01/2005 02:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 222 0 300 300 -16.7 0 -16.5 -16.9 12/01/2005 02:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 222 0 300 300 -16.8 0.1 -16.7 -17.1 12/01/2005 02:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 222 0 300 300 -16.6 0.1 -16.5 -16.9 12/01/2005 02:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 131 30 300 300 -16.4 0 -16.1 -16.5 12/01/2005 02:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 50 45 300 300 -16.5 0.1 -16.3 -16.7 12/01/2005 02:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 19 8 300 300 -16.1 0.1 -15.9 -16.3 12/01/2005 03:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 7 22 300 300 -15.9 0 -15.9 -15.9 12/01/2005 03:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 351 10 300 300 -15.9 0 -15.9 -15.9 12/01/2005 03:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 9 5 300 300 -15.9 0 -15.9 -15.9 12/01/2005 03:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 44 16 300 300 -16 0.1 -15.9 -16.3 12/01/2005 03:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 30 11 300 300 -15.9 0 -15.9 -15.9 12/01/2005 03:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 29 10 300 300 -15.9 0 -15.9 -15.9 12/01/2005 04:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 22 9 300 300 -15.9 0 -15.9 -15.9 12/01/2005 04:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 36 15 300 300 -15.9 0 -15.9 -15.9 12/01/2005 04:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0 9 300 300 -15.8 0.1 -15.5 -15.9 12/01/2005 04:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 29 4 300 300 -15.8 0 -15.5 -15.9 12/01/2005 04:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 4 22 300 300 -15.9 0 -15.9 -15.9 12/01/2005 04:50:00 0.4 0 0.7 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 343 1 342 300 -15.5 0.2 -15.3 -15.9 12/01/2005 05:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 348 8 300 300 -15.7 0.1 -15.3 -15.9 12/01/2005 05:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0 0 300 300 -15.9 0 -15.9 -15.9 12/01/2005 05:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 326 5 300 300 -15.8 0 -15.5 -15.9 12/01/2005 05:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 142 72 300 300 -15.4 0 -15.3 -15.5 12/01/2005 05:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 223 28 300 300 -15.4 0 -15.3 -15.5 12/01/2005 05:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 239 12 300 300 -15.5 0 -15.3 -15.5 12/01/2005 06:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 170 21 300 300 -15.8 0.1 -15.3 -16.1 12/01/2005 06:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 114 28 300 300 -16.3 0.1 -15.9 -16.5 12/01/2005 06:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 11 90 300 300 -16.7 0.1 -16.5 -17.1 12/01/2005 06:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 126 43 300 300 -17.1 0 -16.9 -17.2 12/01/2005 06:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 94 47 300 300 -17.3 0 -17.1 -17.4 12/01/2005 06:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 357 5 300 300 -17.3 0 -17.2 -17.4 12/01/2005 07:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 11 12 300 300 -17.4 0 -17.2 -17.4 12/01/2005 07:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 108 39 300 300 -17.7 0.1 -17.2 -18 12/01/2005 07:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 139 0 300 300 -18 0 -17.8 -18 12/01/2005 07:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 130 35 300 300 -18 0 -17.8 -18.2 12/01/2005 07:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 345 1 300 300 -17.8 0 -17.4 -18 12/01/2005 07:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 123 35 300 300 -18 0 -17.6 -18 12/01/2005 08:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 157 1 300 300 -17.8 0.1 -17.4 -18 12/01/2005 08:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 158 0 300 300 -18 0 -17.6 -18 12/01/2005 08:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 158 0 300 300 -17.8 0 -17.4 -17.8 12/01/2005 08:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 198 27 300 300 -17.8 0 -17.4 -18 12/01/2005 08:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 256 16 300 300 -17.6 0 -17.4 -17.8 12/01/2005 08:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 289 9 300 300 -17.1 0.2 -16.5 -17.4 12/01/2005 09:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 287 17 300 300 -16.7 0.2 -16.5 -17.1 12/01/2005 09:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 300 16 300 300 -16.8 0 -16.7 -16.9 12/01/2005 09:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 283 17 300 300 -16.4 0.1 -16.3 -16.7 12/01/2005 09:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 270 13 300 300 -16.3 0.1 -16.1 -16.5 12/01/2005 09:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 280 13 300 300 -16.1 0 -15.9 -16.3 12/01/2005 09:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 256 24 300 300 -15.9 0 -15.9 -15.9 12/01/2005 10:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 230 6 300 300 -15.9 0 -15.9 -15.9 12/01/2005 10:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 245 16 300 300 -15.7 0.1 -15.5 -15.9 12/01/2005 10:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 248 17 300 300 -15.5 0 -15.3 -15.7 12/01/2005 10:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 276 32 300 300 -15.3 0 -15.3 -15.3 12/01/2005 10:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 228 36 300 300 -15.2 0.1 -15 -15.3 12/01/2005 10:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 287 32 300 300 -15 0 -15 -15 12/01/2005 11:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 354 29 300 300 -14.9 0 -14.8 -15 12/01/2005 11:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 38 7 300 300 -14.6 0 -14.4 -14.8 12/01/2005 11:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 31 7 300 300 -14.4 0 -14.2 -14.6 12/01/2005 11:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 41 5 300 300 -14.2 0 -14 -14.4 12/01/2005 11:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 49 8 300 300 -14.1 0 -14 -14 12/01/2005 11:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 37 18 300 300 -13.9 0 -13.6 -14 12/01/2005 12:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 72 23 300 300 -13.6 0 -13.4 -13.8 12/01/2005 12:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 33 7 300 300 -13.5 0 -13.4 -13.6 12/01/2005 12:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 32 5 300 300 -13.6 0 -13.4 -13.6 12/01/2005 12:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 40 10 300 300 -13.4 0 -13.2 -13.6 12/01/2005 12:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 51 6 300 300 -13.3 0 -13.2 -13.4 12/01/2005 12:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 32 10 300 300 -13.2 0 -13.2 -13.4 12/01/2005 13:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 357 29 300 300 -13.1 0 -13.2 -13.2 12/01/2005 13:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 18 1 300 300 -13 0 -12.8 -13.2 12/01/2005 13:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 18 0 300 300 -12.8 0 -12.6 -13 12/01/2005 13:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 17 0 300 300 -12.6 0 -12.4 -12.6 12/01/2005 13:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 20 2 300 300 -12.5 0 -12.4 -12.6 12/01/2005 13:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 51 28 300 300 -12.5 0 -12.4 -12.6 12/01/2005 14:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 134 23 300 300 -12.4 0 -12.2 -12.4 12/01/2005 14:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.7 0.4 132 14 300 300 -12.2 0 -12.2 -12.2 12/01/2005 14:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 73 16 300 300 -12.4 0 -12.2 -12.6 12/01/2005 14:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 76 28 300 300 -12.5 0 -12.4 -12.6 12/01/2005 14:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 120 66 300 300 -12.6 0 -12.4 -12.6 12/01/2005 14:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 185 0 300 300 -12.5 0 -12.4 -12.6 12/01/2005 15:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 161 36 300 300 -12.5 0 -12.4 -12.6 12/01/2005 15:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 120 20 300 300 -12.6 0 -12.4 -12.6 12/01/2005 15:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 116 8 300 300 -12.8 0 -12.6 -13 12/01/2005 15:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 88 36 300 300 -13 0 -12.8 -13.2 12/01/2005 15:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 38 4 300 300 -13.1 0 -13 -13.2 12/01/2005 15:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 44 4 300 300 -13.1 0 -13.2 -13.2 12/01/2005 16:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 50 6 300 300 -13.2 0 -13.2 -13.6 12/01/2005 16:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 44 6 300 300 -13.2 0 -13.2 -13.4 12/01/2005 16:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 44 6 300 300 -13.2 0 -13.2 -13.2 12/01/2005 16:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 45 6 300 300 -13.3 0 -13.2 -13.4 12/01/2005 16:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 46 4 300 300 -13.4 0 -13.2 -13.4 12/01/2005 16:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 45 7 300 300 -13.4 0 -13.2 -13.4 12/01/2005 17:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 45 5 300 300 -13.4 0 -13.2 -13.4 12/01/2005 17:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 55 4 300 300 -13.3 0 -13.2 -13.4 12/01/2005 17:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 58 0 300 300 -13.3 0 -13.2 -13.4 12/01/2005 17:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 53 7 300 300 -13.3 0 -13.2 -13.4 12/01/2005 17:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 40 0 300 300 -13.2 0 -13.2 -13.4 12/01/2005 17:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 42 1 300 300 -13.2 0 -13.2 -13.2 12/01/2005 18:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 43 1 300 300 -13.1 0 -13.2 -13.2 12/01/2005 18:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 25 3 300 300 -13.1 0 -13.2 -13.2 12/01/2005 18:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 40 8 300 300 -13.1 0 -13.2 -13.2 12/01/2005 18:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 33 2 300 300 -13.1 0 -13.2 -13.2 12/01/2005 18:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 30 7 300 300 -13.1 0 -13 -13.2 12/01/2005 18:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 43 0 300 300 -13.1 0 -13 -13.2 12/01/2005 19:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 42 4 300 300 -13.1 0 -13 -13.2 12/01/2005 19:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 52 16 300 300 -13.1 0 -13 -13.2 12/01/2005 19:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 48 17 300 300 -13.1 0 -13 -13.2 12/01/2005 19:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 27 0 300 300 -13.1 0 -13 -13.2 12/01/2005 19:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 36 13 300 300 -13 0 -13 -13.2 12/01/2005 19:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 39 13 300 300 -13 0 -13 -13.2 12/01/2005 20:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 29 0 300 300 -13 0 -12.8 -13.2 12/01/2005 20:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 29 0 300 300 -13 0 -13 -13.2 12/01/2005 20:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 28 0 300 300 -13 0 -12.8 -13.2 12/01/2005 20:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 28 0 300 300 -13 0 -12.8 -13.2 12/01/2005 20:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 28 0 300 300 -13.1 0 -13 -13.2 12/01/2005 20:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 28 0 300 300 -13.1 0 -13 -13.2 12/01/2005 21:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 28 0 300 300 -13.1 0 -13.2 -13.2 12/01/2005 21:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 28 0 300 300 -13.1 0 -13 -13.2 12/01/2005 21:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 28 0 300 300 -13 0 -13 -13.2 12/01/2005 21:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 28 0 300 300 -12.9 0 -12.8 -13.2 12/01/2005 21:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 28 0 300 300 -12.9 0 -12.8 -13 12/01/2005 21:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 28 0 300 300 -12.9 0 -12.8 -13 12/01/2005 22:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 28 0 300 300 -12.9 0 -12.8 -13 12/01/2005 22:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 28 0 300 300 -12.9 0 -12.8 -13 12/01/2005 22:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 28 0 300 300 -12.9 0 -12.8 -13 12/01/2005 22:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 28 0 300 300 -12.9 0 -12.8 -13 12/01/2005 22:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 28 0 300 300 -12.9 0 -12.8 -13 12/01/2005 22:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 28 0 300 300 -12.9 0 -12.8 -13 12/01/2005 23:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 29 0 300 300 -12.9 0 -12.8 -13 12/01/2005 23:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 29 0 300 300 -12.8 0 -12.8 -13 12/01/2005 23:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 29 0 300 300 -12.9 0 -12.6 -13 12/01/2005 23:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 29 0 300 300 -12.9 0 -12.8 -13 12/01/2005 23:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 64 14 300 300 -13 0 -12.8 -13.2 12/01/2005 23:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 66 15 300 300 -13.1 0 -13.2 -13.2 12/02/2005 00:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 28 9 300 300 -13.1 0 -13.2 -13.2 12/02/2005 00:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 29 8 300 300 -13.2 0 -13.2 -13.2 12/02/2005 00:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 33 3 300 300 -13.2 0 -13.2 -13.4 12/02/2005 00:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 32 3 300 300 -13.3 0 -13.2 -13.4 12/02/2005 00:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 35 1 300 300 -13.2 0 -13.2 -13.4 12/02/2005 00:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 38 2 300 300 -13.1 0 -13.2 -13.2 12/02/2005 01:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 46 2 300 300 -13.1 0 -13 -13.2 12/02/2005 01:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 45 1 300 300 -13.1 0 -13 -13.2 12/02/2005 01:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 39 5 300 300 -13 0 -13 -13.2 12/02/2005 01:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 41 2 300 300 -13 0 -13 -13.2 12/02/2005 01:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 39 2 300 300 -13 0 -12.8 -13.2 12/02/2005 01:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 43 3 300 300 -13.1 0 -13 -13.2 12/02/2005 02:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 29 4 300 300 -13.1 0 -13 -13.2 12/02/2005 02:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 30 3 300 300 -13.2 0 -13.2 -13.2 12/02/2005 02:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 24 5 300 300 -13.3 0 -13.2 -13.4 12/02/2005 02:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 14 2 300 300 -13.5 0 -13.2 -13.6 12/02/2005 02:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 31 7 300 300 -13.6 0 -13.4 -13.6 12/02/2005 02:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 18 5 300 300 -13.7 0 -13.6 -13.8 12/02/2005 03:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 15 3 300 300 -13.7 0 -13.6 -13.8 12/02/2005 03:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 28 6 300 300 -13.7 0 -13.6 -13.6 12/02/2005 03:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 16 2 300 300 -13.6 0 -13.4 -13.6 12/02/2005 03:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 29 4 300 300 -13.3 0 -13.2 -13.4 12/02/2005 03:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 26 3 300 300 -13.1 0 -13.2 -13.2 12/02/2005 03:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 31 2 300 300 -13 0 -12.8 -13.2 12/02/2005 04:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 11 24 300 300 -12.9 0 -12.6 -13 12/02/2005 04:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 351 9 300 300 -12.7 0 -12.6 -12.8 12/02/2005 04:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 359 0 300 300 -12.8 0 -12.6 -13 12/02/2005 04:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 358 0 300 300 -12.8 0 -12.6 -13 12/02/2005 04:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 358 0 300 300 -12.8 0 -12.6 -13 12/02/2005 04:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 359 0 300 300 -13 0 -12.8 -13.2 12/02/2005 05:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 359 0 300 300 -13.1 0 -13.2 -13.2 12/02/2005 05:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 359 0 300 300 -13.1 0 -13.2 -13.2 12/02/2005 05:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 359 0 300 300 -13.1 0 -13 -13.2 12/02/2005 05:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0 4 300 300 -13 0 -12.8 -13.2 12/02/2005 05:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 15 14 300 300 -13 0 -12.8 -13 12/02/2005 05:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 44 0 300 300 -13 0 -12.8 -13.2 12/02/2005 06:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 44 0 300 300 -13 0 -12.8 -13.2 12/02/2005 06:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 44 0 300 300 -12.8 0 -12.6 -13 12/02/2005 06:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 33 8 300 300 -12.7 0 -12.6 -12.8 12/02/2005 06:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 13 6 300 300 -12.6 0 -12.4 -12.8 12/02/2005 06:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 358 4 300 300 -12.4 0 -12.2 -12.6 12/02/2005 06:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 352 0 300 300 -12.3 0 -12.2 -12.4 12/02/2005 07:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 342 9 300 300 -12.3 0 -12.2 -12.4 12/02/2005 07:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 337 2 300 300 -12.4 0 -12.2 -12.4 12/02/2005 07:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 347 10 300 300 -12.4 0 -12.2 -12.4 12/02/2005 07:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 10 1 300 300 -12.4 0 -12.2 -12.4 12/02/2005 07:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 9 0 300 300 -12.3 0 -12.2 -12.4 12/02/2005 07:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 353 17 300 300 -12.1 0 -12 -12.2 12/02/2005 08:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 332 17 300 300 -11.9 0 -11.8 -12 12/02/2005 08:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 6 22 300 300 -12 0 -11.8 -12.2 12/02/2005 08:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 35 0 300 300 -12 0 -12 -12.2 12/02/2005 08:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 35 0 300 300 -12 0 -12 -12.2 12/02/2005 08:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 62 17 300 300 -12.1 0 -12 -12.2 12/02/2005 08:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 48 13 300 300 -12.2 0 -12.2 -12.2 12/02/2005 09:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 39 7 300 300 -12.2 0 -12 -12.2 12/02/2005 09:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 39 9 300 300 -12.3 0 -12.2 -12.4 12/02/2005 09:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 37 9 300 300 -12.4 0 -12.2 -12.4 12/02/2005 09:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 24 3 300 300 -12.4 0 -12.4 -12.6 12/02/2005 09:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 13 4 300 300 -12.4 0 -12.4 -12.6 12/02/2005 09:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 346 11 300 300 -12.4 0 -12.2 -12.6 12/02/2005 10:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 338 0 300 300 -12.3 0 -12.2 -12.4 12/02/2005 10:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 356 27 300 300 -12.4 0 -12.2 -12.4 12/02/2005 10:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 26 11 300 300 -12.4 0 -12.2 -12.4 12/02/2005 10:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 30 11 300 300 -12.1 0 -12 -12.2 12/02/2005 10:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 11 21 300 300 -12 0 -11.8 -12.2 12/02/2005 10:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 333 11 300 300 -11.9 0 -11.8 -12 12/02/2005 11:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 325 0 300 300 -11.7 0 -11.6 -11.8 12/02/2005 11:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 356 27 300 300 -11.6 0 -11.4 -11.6 12/02/2005 11:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 26 7 300 300 -11.5 0 -11.4 -11.6 12/02/2005 11:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 16 9 300 300 -11.5 0 -11.4 -11.4 12/02/2005 11:40:00 0.4 0.1 0.7 0.4 0.4 0 0.7 0.4 0.4 0.1 0.7 0.4 19 15 342 300 -11.3 0.1 -11 -11.4 12/02/2005 11:50:00 0.4 0.1 1.1 0.4 2.3 1.4 5.7 0.4 0.4 0.1 1.1 0.4 26 13 33 300 -10.7 0.2 -10.4 -11 12/02/2005 12:00:00 0.4 0.1 0.7 0.4 3 0.9 5.3 1.1 0.4 0.1 0.7 0.4 29 13 43 300 -10.4 0 -10.2 -10.4 12/02/2005 12:10:00 2.5 1.2 4.6 0.4 3.2 0.8 5.3 1.1 0.4 0.1 0.7 0.4 34 14 20 300 -10.4 0 -10.2 -10.4 12/02/2005 12:20:00 2.4 0.8 4.2 0.4 2.7 1 4.6 0.4 0.4 0 0.7 0.4 39 17 29 300 -10.4 0 -10.4 -10.4 12/02/2005 12:30:00 1.5 0.9 3.8 0.4 1.8 1 4.6 0.4 0.4 0 0.7 0.4 51 30 58 300 -10.3 0 -10.2 -10.4 12/02/2005 12:40:00 4 1.3 6.8 1.5 3.9 1.5 7.2 1.1 1.6 1.6 6.1 0.4 15 17 8 300 -10.2 0 -10.2 -10.4 12/02/2005 12:50:00 4.5 0.9 6.5 1.9 4.7 1 6.8 2.3 3.4 1 5.3 1.1 355 14 352 300 -10 0 -9.7 -10.2 12/02/2005 13:00:00 5.2 1.1 8.8 3 5.2 1.1 8.8 2.6 3.9 1 6.8 1.5 3 17 7 300 -10 0 -10 -10.2 12/02/2005 13:10:00 4.6 1 7.2 2.3 4.6 1.1 7.2 1.9 3.5 1 6.1 1.1 1 15 357 300 -10.1 0 -10 -10.2 12/02/2005 13:20:00 4.3 0.9 6.5 2.3 4.2 1 6.8 1.5 3 0.8 5.3 1.1 6 14 18 300 -10.1 0 -10.2 -10.2 12/02/2005 13:30:00 4.4 1 7.2 2.3 4.2 1.1 7.2 1.9 3.1 1 6.1 0.7 11 16 7 300 -10.1 0 -10 -10.2 12/02/2005 13:40:00 4.7 1 7.6 2.6 4.7 1 7.6 2.3 3.5 0.9 6.5 1.1 3 12 5 300 -10.1 0 -10 -10.2 12/02/2005 13:50:00 4.2 0.9 6.8 2.3 3.9 1 6.8 1.5 2.9 0.9 5.3 1.1 16 13 349 300 -10.1 0 -10 -10.2 12/02/2005 14:00:00 5.9 1 9.1 3.4 5.6 1.1 9.1 2.6 4.2 1.1 7.2 1.1 18 12 13 300 -9.8 0 -9.7 -10 12/02/2005 14:10:00 5.6 1.1 9.5 3.4 5.3 1.2 8.8 2.6 3.8 1 6.8 1.9 19 13 35 300 -9.8 0 -9.7 -9.7 12/02/2005 14:20:00 5.7 1.5 9.1 2.3 5.6 1.7 9.5 1.9 4.3 1.3 8.4 1.9 11 14 353 300 -9.4 0 -9.3 -9.7 12/02/2005 14:30:00 4.4 1.1 7.6 2.3 4.2 1.2 7.6 1.5 3.4 1 6.5 1.1 26 18 34 300 -9.5 0.1 -9.3 -9.7 12/02/2005 14:40:00 2.8 0.6 4.2 1.5 2.6 0.7 4.6 0.7 1.9 0.6 3.8 0.4 23 13 47 300 -9.8 0 -9.7 -9.7 12/02/2005 14:50:00 5.1 1.7 8.8 1.5 4.8 1.7 8.8 1.1 3.6 1.3 7.2 1.1 17 15 35 300 -9.8 0 -9.7 -9.7 12/02/2005 15:00:00 5.2 1.1 7.6 2.6 4.8 1.1 7.6 2.3 3.7 1 6.8 1.5 28 12 24 300 -9.7 0 -9.5 -9.7 12/02/2005 15:10:00 5.1 1.1 8.4 3 4.8 1.3 8.8 2.3 3.7 1 7.2 1.5 24 13 20 300 -9.7 0 -9.5 -9.7 12/02/2005 15:20:00 4.5 1.1 7.6 2.3 4.3 1.1 7.6 1.5 3.5 1.1 7.2 1.1 36 11 37 300 -9.8 0 -9.7 -9.7 12/02/2005 15:30:00 2.2 1 4.6 0.4 2.1 1 4.6 0.4 1.7 0.8 4.2 0.4 42 22 39 300 -10.1 0.2 -9.7 -10.4 12/02/2005 15:40:00 2 0.7 3.8 0.4 1.8 0.8 3.8 0.4 1.3 0.5 3 0.4 28 17 22 300 -10.4 0 -10.4 -10.6 12/02/2005 15:50:00 2.9 0.9 4.9 1.1 2.6 0.9 4.9 0.7 2 0.8 4.6 0.4 14 14 4 300 -10.2 0 -10 -10.4 12/02/2005 16:00:00 3.5 1 6.1 1.5 3.3 1.1 6.1 1.1 2.5 0.8 4.9 0.7 21 17 20 300 -9.8 0 -9.7 -10 12/02/2005 16:10:00 3.9 0.9 6.5 1.9 3.8 1 6.5 1.1 3.1 0.9 5.3 1.5 11 12 6 300 -9.8 0 -9.7 -10.2 12/02/2005 16:20:00 4.5 1.1 7.2 1.9 4.3 1.2 7.6 1.5 3.4 1 7.6 1.1 15 12 2 300 -9.8 0 -9.7 -10 12/02/2005 16:30:00 5 1.1 8 2.3 4.7 1.1 7.2 1.5 3.9 1 6.8 1.1 16 13 20 300 -9.6 0 -9.5 -9.7 12/02/2005 16:40:00 5 1.1 8.4 2.3 4.7 1.2 8.4 1.9 3.7 1 6.8 1.5 21 15 358 300 -9.5 0 -9.3 -9.7 12/02/2005 16:50:00 5.4 1.3 8 1.9 5.1 1.4 8.4 1.9 4 1.1 7.2 1.5 16 15 8 300 -9.6 0 -9.3 -9.7 12/02/2005 17:00:00 5.7 1.5 9.1 1.9 5.4 1.6 9.1 1.9 4.5 1.5 8.4 1.5 17 18 25 300 -9.6 0 -9.5 -9.7 12/02/2005 17:10:00 6.1 1.3 9.5 2.6 5.8 1.5 9.9 2.3 4.8 1.3 9.1 1.5 11 16 10 300 -9.7 0 -9.7 -9.7 12/02/2005 17:20:00 7.5 1.8 13.7 3 7.1 1.8 13.3 2.6 5.9 1.7 10.7 1.9 12 15 357 300 -9.6 0 -9.5 -9.7 12/02/2005 17:30:00 4.9 1.1 8.8 2.3 4.5 1.1 8 1.9 3.7 1 8 1.1 22 14 26 300 -9.7 0 -9.5 -9.7 12/02/2005 17:40:00 5.4 1.5 9.5 1.1 4.9 1.5 9.1 0.7 3.8 1.3 7.6 0.4 30 16 25 300 -9.8 0 -9.7 -9.7 12/02/2005 17:50:00 4.6 1.3 7.6 1.1 4.3 1.3 7.6 0.4 3.4 1.2 7.2 0.7 37 17 29 300 -9.8 0 -9.7 -10 12/02/2005 18:00:00 2.3 0.6 3.8 0.7 2.2 0.7 3.4 0.7 1.9 0.5 3.4 0.7 59 15 45 300 -10.4 0.2 -9.7 -10.6 12/02/2005 18:10:00 2.9 1 5.3 1.1 2.7 1 4.9 0.7 2.1 0.8 3.8 0.4 39 14 24 300 -10.8 0 -10.6 -11 12/02/2005 18:20:00 3 0.6 4.6 1.5 2.8 0.7 4.6 1.1 1.9 0.7 4.2 0.7 42 13 22 300 -10.7 0 -10.6 -11 12/02/2005 18:30:00 3 1 5.3 1.1 2.6 1.1 4.9 0.7 2.2 0.9 4.6 0.7 30 15 19 300 -10.5 0.1 -10.4 -10.8 12/02/2005 18:40:00 3.1 1.2 6.1 0.7 2.9 1.3 5.7 0.4 2.3 1.1 5.3 0.4 43 15 45 300 -10.4 0 -10.2 -10.4 12/02/2005 18:50:00 1.6 0.4 2.6 0.4 1.5 0.5 2.3 0.4 1.2 0.5 2.3 0.4 60 9 58 300 -10.5 0 -10.4 -10.6 12/02/2005 19:00:00 0.6 0.3 1.5 0.4 0.5 0.3 1.5 0.4 0.4 0.1 1.1 0.4 55 20 70 300 -10.7 0 -10.6 -10.8 12/02/2005 19:10:00 1.3 1.4 4.6 0.4 1.2 1.2 4.2 0.4 0.9 1 4.2 0.4 8 30 16 300 -10.8 0 -10.6 -11 12/02/2005 19:20:00 1.1 0.6 2.6 0.4 1 0.6 2.6 0.4 1.2 0.7 2.6 0.4 133 43 35 300 -10.9 0 -10.6 -11.2 12/02/2005 19:30:00 1.2 0.5 2.3 0.4 0.9 0.5 1.9 0.4 0.6 0.3 1.5 0.4 36 9 37 300 -11.1 0 -11 -11.2 12/02/2005 19:40:00 1 0.4 1.9 0.4 0.8 0.4 1.9 0.4 0.6 0.3 1.5 0.4 31 11 28 300 -11.1 0 -11 -11.2 12/02/2005 19:50:00 1.4 0.6 2.6 0.4 1.3 0.6 2.3 0.4 0.9 0.4 1.9 0.4 53 9 40 300 -11.4 0 -11.2 -11.4 12/02/2005 20:00:00 0.4 0.2 1.5 0.4 0.4 0.1 1.1 0.4 0.4 0 0.4 0.4 39 11 56 300 -11.5 0 -11.4 -11.4 12/02/2005 20:10:00 0.5 0.2 1.1 0.4 0.4 0.1 1.1 0.4 0.6 0.4 2.3 0.4 302 90 34 300 -11.5 0 -11.4 -11.6 12/02/2005 20:20:00 0.5 0.2 1.1 0.4 0.4 0.1 1.1 0.4 0.6 0.3 1.5 0.4 167 9 147 300 -11.8 0.1 -11.6 -12.2 12/02/2005 20:30:00 0.4 0.1 1.1 0.4 0.4 0 0.7 0.4 0.4 0 0.4 0.4 295 82 32 300 -12.3 0.1 -12 -12.4 12/02/2005 20:40:00 0.4 0.1 1.1 0.4 0.4 0 0.4 0.4 0.5 0.3 1.5 0.4 93 22 105 300 -12.4 0 -12.2 -12.6 12/02/2005 20:50:00 0.4 0.2 1.1 0.4 0.4 0.1 1.1 0.4 0.6 0.4 1.5 0.4 104 3 94 300 -12.6 0.1 -12.2 -12.6 12/02/2005 21:00:00 1.2 0.2 1.5 0.7 1 0.2 1.5 0.4 1.5 0.3 1.9 0.4 76 9 85 300 -12.4 0.1 -12.2 -12.6 12/02/2005 21:10:00 1.8 0.6 2.6 0.4 1.7 0.6 2.6 0.4 1.5 0.4 2.3 0.4 54 3 53 300 -12.5 0 -12.4 -12.6 12/02/2005 21:20:00 2.3 0.3 3 1.5 2.3 0.3 3 1.5 1.8 0.4 2.6 0.4 63 5 66 300 -12.4 0 -12.2 -12.6 12/02/2005 21:30:00 2 0.5 3 0.7 1.9 0.5 3 0.4 1.5 0.6 2.6 0.4 68 5 67 300 -12.4 0 -12.2 -12.4 12/02/2005 21:40:00 2.8 0.4 3.8 1.9 2.7 0.4 3.8 1.9 1.9 0.4 3 0.7 52 8 49 300 -12.2 0 -12 -12.4 12/02/2005 21:50:00 2 0.4 3 1.1 1.8 0.5 2.6 0.7 1.2 0.5 3 0.4 42 10 46 300 -11.9 0.1 -11.8 -12.2 12/02/2005 22:00:00 2.2 0.4 3 1.1 2.1 0.5 3 0.4 1.3 0.6 2.6 0.4 52 7 51 300 -11.6 0 -11.6 -11.8 12/02/2005 22:10:00 2 0.5 3 0.7 1.8 0.6 3 0.4 1.1 0.5 2.6 0.4 37 8 43 300 -11.7 0 -11.6 -11.8 12/02/2005 22:20:00 2.1 0.3 3 1.5 2 0.4 2.6 0.7 1.3 0.3 2.3 0.4 40 6 44 300 -11.9 0 -11.8 -12 12/02/2005 22:30:00 2.2 0.4 3 1.5 2.1 0.4 2.6 1.1 1.3 0.5 2.3 0.4 52 7 48 300 -12.2 0.2 -11.8 -12.6 12/02/2005 22:40:00 2.3 0.3 3 1.5 2.3 0.3 3 1.5 1.4 0.5 2.3 0.4 62 11 64 300 -12.6 0 -12.6 -12.8 12/02/2005 22:50:00 1.5 0.3 2.3 0.7 1.4 0.4 2.3 0.7 1.1 0.3 2.3 0.4 69 16 78 300 -12.6 0.1 -12.2 -12.8 12/02/2005 23:00:00 3 0.7 4.6 1.1 2.7 0.8 4.2 0.7 1.9 0.5 3 0.7 19 10 20 300 -12.6 0.2 -12.2 -13 12/02/2005 23:10:00 3.1 0.3 3.8 2.3 3 0.4 3.8 1.9 2.1 0.5 3.4 1.1 43 7 47 300 -12.6 0 -12.4 -12.8 12/02/2005 23:20:00 2.3 0.6 3.8 1.1 2.1 0.7 3.8 0.7 1.3 0.6 2.6 0.4 36 6 40 300 -12.5 0 -12.4 -12.6 12/02/2005 23:30:00 3.3 0.7 4.9 1.9 3 0.8 4.9 1.5 2.1 0.6 3.8 0.7 36 10 48 300 -12.6 0.1 -12.4 -12.6 12/02/2005 23:40:00 4 0.5 4.9 2.3 3.4 0.6 4.6 1.5 2.3 0.5 3.8 1.1 25 7 30 300 -12.5 0 -12.2 -12.6 12/02/2005 23:50:00 3.7 0.5 4.9 2.6 3.2 0.5 4.6 1.9 2.1 0.4 3 1.1 28 7 24 300 -12.8 0.1 -12.4 -13 12/03/2005 00:00:00 2.6 1 4.6 0.4 2.3 0.9 4.6 0.4 1.6 0.6 3.4 0.4 37 12 27 300 -12.9 0 -12.8 -13 12/03/2005 00:10:00 1.1 0.6 2.6 0.4 0.9 0.6 2.6 0.4 1.1 0.4 2.3 0.4 67 14 46 300 -13.1 0 -13 -13.4 12/03/2005 00:20:00 1.4 0.4 2.3 0.7 1.2 0.5 2.3 0.4 1.1 0.4 1.9 0.4 36 27 12 300 -13.6 0 -13.4 -13.8 12/03/2005 00:30:00 1.5 0.2 2.3 1.1 1.3 0.3 2.3 0.4 0.9 0.4 1.5 0.4 32 14 8 300 -13.7 0 -13.6 -13.8 12/03/2005 00:40:00 0.9 0.5 1.9 0.4 0.8 0.4 1.9 0.4 0.5 0.3 1.5 0.4 28 9 46 300 -14.5 0.3 -13.6 -15 12/03/2005 00:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 23 0 300 300 -14.6 0 -14.4 -14.8 12/03/2005 01:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0.1 1.1 0.4 6 15 300 300 -14.6 0.2 -14.2 -15 12/03/2005 01:10:00 0.4 0.2 0.7 0.4 0.4 0 0.4 0.4 1 0.2 1.5 0.4 338 8 339 300 -14.9 0 -14.8 -15 12/03/2005 01:20:00 1.3 0.5 2.3 0.4 1.2 0.5 2.3 0.4 1.6 0.4 2.3 0.7 303 23 333 300 -15 0 -15 -15.1 12/03/2005 01:30:00 2.8 0.5 3.4 1.9 2.8 0.5 3.4 1.9 2.5 0.5 3.4 1.5 350 10 346 300 -15.2 0.3 -14.8 -15.9 12/03/2005 01:40:00 2.9 0.4 3.8 1.9 2.7 0.5 3.8 1.5 1.9 0.6 3.4 0.7 16 9 9 300 -15.9 0 -15.5 -15.9 12/03/2005 01:50:00 3 0.5 3.8 1.9 2.7 0.5 3.8 1.5 1.8 0.4 3 0.7 31 6 24 300 -16.3 0.2 -15.9 -16.7 12/03/2005 02:00:00 1.6 0.4 2.6 0.7 1.5 0.4 2.3 0.4 1 0.4 1.9 0.4 57 12 41 300 -16 0.6 -15 -16.7 12/03/2005 02:10:00 1.1 0.3 1.9 0.4 0.9 0.4 1.5 0.4 0.9 0.4 1.9 0.4 61 12 71 300 -15.9 0.5 -15 -16.5 12/03/2005 02:20:00 1.6 0.5 2.6 0.7 1.2 0.5 2.3 0.4 1 0.3 1.5 0.4 30 11 20 300 -15.8 0.2 -15.5 -16.1 12/03/2005 02:30:00 2.2 0.3 2.6 1.5 1.8 0.3 2.6 1.1 1.2 0.3 1.9 0.7 20 3 24 300 -16.4 0.2 -15.9 -16.7 12/03/2005 02:40:00 1.8 0.6 3 0.7 1.4 0.6 2.6 0.4 0.7 0.5 1.9 0.4 26 4 24 300 -16.7 0 -16.5 -16.9 12/03/2005 02:50:00 1.3 0.3 1.9 0.7 1.1 0.3 1.5 0.4 0.7 0.3 1.5 0.4 42 5 43 300 -16.9 0.2 -16.5 -17.4 12/03/2005 03:00:00 2 0.2 2.6 1.5 1.5 0.3 2.3 1.1 1 0.2 1.5 0.4 26 5 21 300 -16.8 0.4 -16.1 -17.4 12/03/2005 03:10:00 2.1 0.2 3 1.5 1.7 0.3 2.6 1.1 1.3 0.3 1.9 0.7 22 3 23 300 -16.7 0.2 -16.3 -17.1 12/03/2005 03:20:00 3 0.5 4.2 1.9 2.4 0.5 3.4 1.1 2 0.4 3 1.1 21 2 21 300 -17 0 -16.7 -17.1 12/03/2005 03:30:00 3.8 0.2 4.2 3 3.2 0.3 4.2 2.3 2.3 0.4 3.4 1.5 20 3 27 300 -16.9 0 -16.7 -17.1 12/03/2005 03:40:00 3.8 0.4 4.9 2.6 3.5 0.5 4.9 2.3 2.3 0.5 3.4 1.1 14 5 11 300 -16.8 0.2 -16.5 -17.1 12/03/2005 03:50:00 3.8 0.4 4.9 3 3.7 0.4 4.9 2.6 2.6 0.5 3.8 1.5 14 4 11 300 -16.3 0.2 -15.9 -16.5 12/03/2005 04:00:00 3.6 0.4 4.6 2.6 3.6 0.5 4.6 2.3 2.4 0.5 3.4 1.5 10 5 11 300 -16 0 -15.9 -16.3 12/03/2005 04:10:00 3.5 0.4 4.6 2.6 2.9 0.4 4.2 1.9 1.9 0.4 3 1.1 23 5 16 300 -16.9 0.3 -16.1 -17.4 12/03/2005 04:20:00 3 0.7 4.2 1.5 2.7 0.7 4.2 1.1 1.6 0.6 3 0.4 32 5 43 300 -16.4 0.1 -16.1 -16.7 12/03/2005 04:30:00 1.4 0.5 2.3 0.4 1 0.5 2.3 0.4 0.5 0.3 1.1 0.4 30 7 32 300 -15.7 0.2 -15.3 -16.3 12/03/2005 04:40:00 2 0.4 3 0.7 1.6 0.5 2.6 0.4 0.9 0.4 1.9 0.4 21 7 21 300 -16 0.1 -15.5 -16.3 12/03/2005 04:50:00 2.3 0.3 3 1.5 2.2 0.3 3 1.5 1.7 0.3 2.3 1.1 48 10 41 300 -16.9 0.3 -16.3 -17.4 12/03/2005 05:00:00 1.7 0.4 2.6 0.7 1.5 0.4 2.6 0.4 1.1 0.4 1.9 0.4 78 8 76 300 -17.6 0 -17.2 -17.8 12/03/2005 05:10:00 2.3 0.3 3 1.5 2.3 0.3 3 1.5 1.8 0.3 2.6 0.7 71 5 64 300 -17.5 0 -17.2 -17.4 12/03/2005 05:20:00 2.2 0.5 3 1.1 2.1 0.5 3 0.7 1.6 0.5 2.3 0.4 62 8 57 300 -17.4 0 -17.2 -17.4 12/03/2005 05:30:00 2.9 0.2 3.4 2.3 2.9 0.2 3.4 2.3 1.9 0.3 2.6 1.1 48 2 49 300 -16.9 0.2 -16.5 -17.4 12/03/2005 05:40:00 2.5 0.3 3 1.9 2.2 0.3 2.6 1.1 1.3 0.4 2.3 0.7 35 4 33 300 -16.9 0.2 -16.5 -17.1 12/03/2005 05:50:00 1 0.5 2.3 0.4 0.6 0.4 1.9 0.4 0.5 0.2 1.1 0.4 40 11 34 300 -17.2 0.1 -17.1 -17.4 12/03/2005 06:00:00 1 0.3 1.5 0.4 0.7 0.3 1.1 0.4 0.8 0.4 1.5 0.4 71 28 44 300 -18.3 0.4 -17.4 -18.7 12/03/2005 06:10:00 1.3 0.3 2.3 0.4 1 0.4 1.9 0.4 1.4 0.3 2.3 0.7 124 6 129 300 -18.5 0.3 -17.8 -18.9 12/03/2005 06:20:00 1.9 0.3 2.6 1.1 1.7 0.4 2.6 1.1 1.5 0.5 2.3 0.4 94 17 79 300 -17.9 0.2 -17.2 -18.2 12/03/2005 06:30:00 2.4 0.2 3 1.9 2.4 0.2 3 1.9 2.5 0.2 3 1.9 68 3 63 300 -17.1 0.2 -16.7 -17.4 12/03/2005 06:40:00 2.3 0.2 2.6 1.9 2.4 0.2 2.6 1.9 2.5 0.3 3 1.9 61 5 67 300 -16.6 0.2 -16.1 -17.1 12/03/2005 06:50:00 3 0.2 3.4 2.3 3 0.2 3.4 2.3 2.7 0.3 3.4 1.9 48 7 56 300 -16.5 0.4 -15.9 -17.1 12/03/2005 07:00:00 3 0.3 3.4 2.3 3 0.3 3.4 1.9 2 0.4 3 1.1 41 5 33 300 -16.3 0.4 -15.7 -17.1 12/03/2005 07:10:00 2.7 0.2 3 2.3 2.6 0.2 3 1.9 1.5 0.4 2.6 0.7 38 6 42 300 -15.3 0.1 -15 -15.7 12/03/2005 07:20:00 2.6 0.2 3 2.3 2.3 0.4 3.4 1.5 2 0.4 2.6 1.1 24 7 29 300 -14.8 0.2 -14.6 -15.1 12/03/2005 07:30:00 3.3 0.4 4.2 2.3 3 0.4 3.8 1.9 1.9 0.4 3 1.1 28 7 29 300 -15 0.3 -14.6 -15.5 12/03/2005 07:40:00 2.3 0.8 3.4 0.4 2.1 0.8 3 0.4 1.4 0.4 2.6 0.4 27 7 27 300 -14.8 0.2 -14.6 -15.3 12/03/2005 07:50:00 1 0.6 1.9 0.4 0.8 0.5 1.9 0.4 1.4 0.6 2.3 0.4 356 13 355 300 -14.3 0.2 -13.8 -14.8 12/03/2005 08:00:00 1.2 0.5 2.3 0.4 1 0.5 2.3 0.4 1.8 0.5 2.6 0.7 5 9 7 300 -14.1 0.3 -13.8 -14.6 12/03/2005 08:10:00 2.1 0.5 3 0.7 2.1 0.6 3 0.7 2.1 0.2 2.6 1.5 5 6 2 300 -14.9 0.2 -14.4 -15.3 12/03/2005 08:20:00 2.3 0.4 3 1.1 2.1 0.5 3 0.7 2 0.3 3 1.5 10 6 4 300 -14.6 0 -14.6 -14.8 12/03/2005 08:30:00 2.3 0.2 3 1.5 2.1 0.3 2.6 1.1 1.6 0.3 2.3 0.7 14 4 18 300 -14.9 0.1 -14.6 -15.1 12/03/2005 08:40:00 2.5 0.3 3 1.9 2.4 0.4 3.4 1.5 1.8 0.4 2.6 0.7 20 13 12 300 -15.3 0.3 -14.8 -15.9 12/03/2005 08:50:00 2.4 0.3 3.4 1.9 2.1 0.4 3 1.1 1.6 0.4 2.6 0.7 24 9 24 300 -15.9 0 -15.5 -15.9 12/03/2005 09:00:00 2.1 0.5 3.4 0.7 2 0.5 3 0.7 1.8 0.4 2.6 1.1 1 8 358 300 -14.6 0.6 -14 -15.9 12/03/2005 09:10:00 3 0.6 4.2 0.7 3 0.7 4.2 0.4 2.3 0.5 3.4 0.7 354 7 350 300 -15.2 0.2 -14.6 -15.9 12/03/2005 09:20:00 1.6 0.8 3.4 0.4 1.3 0.9 3.4 0.4 1.4 0.8 3 0.4 55 22 75 300 -16.5 0.1 -15.9 -16.9 12/03/2005 09:30:00 1.1 0.5 2.3 0.4 0.9 0.4 2.3 0.4 0.8 0.4 1.9 0.4 78 17 79 300 -16.4 0.1 -15.9 -16.7 12/03/2005 09:40:00 0.6 0.3 1.5 0.4 0.5 0.2 1.5 0.4 0.5 0.2 1.5 0.4 14 18 7 300 -16 0.2 -15.5 -16.3 12/03/2005 09:50:00 1.2 0.5 2.3 0.4 0.9 0.5 1.9 0.4 1.1 0.4 1.9 0.4 91 30 103 300 -16.2 0.2 -15.9 -16.5 12/03/2005 10:00:00 0.5 0.3 1.5 0.4 0.4 0.1 1.1 0.4 0.5 0.2 1.5 0.4 31 17 16 300 -16.2 0.1 -15.9 -16.5 12/03/2005 10:10:00 1.4 0.2 1.9 1.1 1.1 0.3 1.9 0.4 0.9 0.3 1.5 0.4 12 3 9 300 -16.4 0.2 -16.1 -16.9 12/03/2005 10:20:00 1 0.4 1.9 0.4 0.8 0.5 1.9 0.4 1 0.4 1.9 0.4 13 10 14 300 -16.6 0.2 -16.3 -17.1 12/03/2005 10:30:00 1.1 0.3 1.9 0.4 0.9 0.4 1.9 0.4 0.9 0.3 1.5 0.4 12 13 355 300 -16.3 0.5 -15.5 -17.1 12/03/2005 10:40:00 0.9 0.2 1.5 0.4 0.5 0.2 1.1 0.4 0.7 0.3 1.5 0.4 35 13 20 300 -15.8 0.1 -15.5 -15.9 12/03/2005 10:50:00 1.1 0.3 1.9 0.7 0.8 0.4 1.5 0.4 0.9 0.4 1.9 0.4 31 7 27 300 -15.9 0.3 -15 -16.3 12/03/2005 11:00:00 1.7 0.2 2.3 1.1 1.5 0.2 1.9 1.1 1.3 0.3 1.9 0.7 31 6 28 300 -15.1 0.3 -14.6 -15.5 12/03/2005 11:10:00 1.8 0.4 2.3 1.1 1.6 0.4 2.3 0.7 1.1 0.4 1.9 0.4 27 2 26 300 -15.1 0.2 -14.8 -15.5 12/03/2005 11:20:00 2.5 0.4 3 1.9 2.2 0.6 3 1.1 1.6 0.3 2.3 0.7 32 7 39 300 -14.6 0.3 -14.2 -15.1 12/03/2005 11:30:00 2.4 0.3 3 1.9 2 0.4 3 1.1 1.3 0.3 2.3 0.4 25 4 32 300 -14.8 0 -14.6 -15 12/03/2005 11:40:00 1.9 0.4 2.6 1.1 1.7 0.5 3 0.7 1 0.5 1.9 0.4 18 3 14 300 -14.4 0 -14.2 -14.6 12/03/2005 11:50:00 1.5 0.2 1.9 0.7 1.1 0.3 1.9 0.4 0.4 0.1 0.7 0.4 25 2 26 300 -14.4 0.1 -14.2 -14.8 12/03/2005 12:00:00 1 0.3 1.9 0.4 0.8 0.3 1.5 0.4 0.4 0 0.4 0.4 24 2 22 300 -14.8 0 -14.6 -15 12/03/2005 12:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 29 0 300 300 -14.8 0 -14.6 -15 12/03/2005 12:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 29 0 300 300 -14.2 0.1 -14 -14.6 12/03/2005 12:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 88 23 300 300 -13.9 0.1 -13.6 -14 12/03/2005 12:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 103 8 300 300 -13.5 0.1 -13.2 -13.6 12/03/2005 12:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 117 0 300 300 -13.1 0 -13.2 -13.2 12/03/2005 13:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 117 0 300 300 -13.1 0 -13 -13.2 12/03/2005 13:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 117 0 300 300 -12.9 0 -12.8 -13.2 12/03/2005 13:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0.1 0.7 0.4 171 72 300 300 -13.3 0.1 -13 -13.6 12/03/2005 13:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 271 0 300 300 -13.5 0 -13.4 -13.6 12/03/2005 13:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 271 0 300 300 -13.3 0 -13.2 -13.6 12/03/2005 13:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.7 0.3 1.5 0.4 271 0 300 300 -13.5 0 -13.4 -13.6 12/03/2005 14:00:00 0.8 0.3 1.1 0.4 0.6 0.3 1.1 0.4 1 0.2 1.5 0.4 53 32 47 300 -13.3 0.1 -13 -13.6 12/03/2005 14:10:00 1.1 0.2 1.5 0.7 0.9 0.2 1.1 0.4 1 0.4 1.5 0.4 42 3 43 300 -13 0 -13 -13.2 12/03/2005 14:20:00 1.3 0.2 1.5 0.7 1.2 0.2 1.5 0.7 0.8 0.3 1.5 0.4 38 5 34 300 -12.8 0 -12.6 -13.2 12/03/2005 14:30:00 0.6 0.3 1.1 0.4 0.5 0.2 1.1 0.4 0.5 0.2 1.1 0.4 41 4 46 300 -12.9 0 -12.6 -13.2 12/03/2005 14:40:00 0.4 0 0.4 0.4 0.4 0.1 0.7 0.4 0.7 0.3 1.5 0.4 38 0 300 300 -12.8 0 -12.6 -13 12/03/2005 14:50:00 1.1 0.5 1.9 0.4 1.1 0.3 1.9 0.4 0.9 0.2 1.5 0.4 37 2 35 300 -12.5 0 -12.4 -12.6 12/03/2005 15:00:00 2.1 0.2 2.6 1.5 1.8 0.3 2.3 1.1 1.2 0.3 1.9 0.4 28 6 24 300 -12.9 0 -12.6 -13.2 12/03/2005 15:10:00 1.6 0.2 2.3 1.1 1.6 0.2 2.3 1.1 0.9 0.3 1.5 0.4 12 3 21 300 -13.1 0 -12.8 -13.2 12/03/2005 15:20:00 1.7 0.2 2.3 1.1 1.6 0.2 2.3 1.1 1.3 0.2 1.9 0.7 10 0 10 300 -12.8 0 -12.6 -13 12/03/2005 15:30:00 2.1 0.2 2.3 1.5 2 0.2 2.3 1.5 1.9 0.3 2.6 1.1 7 2 10 300 -12.8 0 -12.6 -13 12/03/2005 15:40:00 2 0.2 2.3 1.5 1.8 0.4 2.6 1.1 1.7 0.2 2.3 1.1 13 3 5 300 -13.1 0.2 -12.6 -13.6 12/03/2005 15:50:00 2.1 0.2 2.6 1.5 2 0.3 2.6 1.1 1.4 0.4 2.3 0.4 26 9 14 300 -13.6 0 -13.4 -13.8 12/03/2005 16:00:00 2 0.2 2.6 1.5 1.8 0.3 2.3 1.1 1.5 0.3 2.3 0.7 33 5 34 300 -14.1 0.1 -13.6 -14.2 12/03/2005 16:10:00 2.2 0.2 2.6 1.9 1.8 0.4 2.6 1.1 1.5 0.3 2.3 0.7 25 4 25 300 -14.1 0 -14 -14.2 12/03/2005 16:20:00 2.4 0.2 2.6 1.9 2.4 0.2 2.6 1.9 1.4 0.3 2.3 0.7 36 2 34 300 -14.6 0.2 -14 -15 12/03/2005 16:30:00 2.5 0.2 3 2.3 2.5 0.2 2.6 1.9 2 0.2 2.6 1.5 46 2 48 300 -15 0.1 -14.8 -15.1 12/03/2005 16:40:00 2.3 0.3 2.6 1.9 2.3 0.3 2.6 1.9 1.7 0.2 2.3 1.1 46 0 46 300 -15 0 -14.8 -15.1 12/03/2005 16:50:00 1.8 0.2 2.3 1.5 1.7 0.2 2.3 1.5 1.2 0.2 1.9 0.7 48 1 46 300 -15.6 0.3 -15 -16.1 12/03/2005 17:00:00 2.1 0.3 2.6 1.5 2 0.3 2.6 1.5 1.8 0.3 2.6 1.1 51 2 54 300 -16.1 0 -15.9 -16.3 12/03/2005 17:10:00 2.6 0.2 3 2.3 2.5 0.2 2.6 1.9 2.2 0.2 2.6 1.9 47 3 51 300 -16.2 0 -15.9 -16.5 12/03/2005 17:20:00 2.4 0.2 3 1.9 2.3 0.2 3 1.9 1.9 0.3 2.6 1.1 45 4 50 300 -16 0 -15.9 -16.1 12/03/2005 17:30:00 3.1 0.3 3.8 2.3 3.1 0.3 3.4 2.3 2.4 0.3 3 1.5 46 4 41 300 -16.2 0 -15.9 -16.5 12/03/2005 17:40:00 3.4 0.2 3.8 2.6 3.3 0.2 3.8 2.6 2 0.3 2.6 1.1 38 3 39 300 -15.8 0 -15.5 -15.9 12/03/2005 17:50:00 3.3 0.2 3.8 2.6 3.3 0.2 3.8 2.6 2 0.4 3 1.1 41 6 35 300 -15.5 0 -15.3 -15.7 12/03/2005 18:00:00 3.2 0.2 3.8 2.6 3.2 0.2 3.4 2.6 2.5 0.2 3 1.9 57 3 54 300 -15.9 0.3 -15.5 -16.5 12/03/2005 18:10:00 3.1 0.2 3.8 2.6 3 0.2 3.4 2.6 2.1 0.4 2.6 1.1 47 8 40 300 -16.6 0.1 -16.3 -16.9 12/03/2005 18:20:00 2.9 0.2 3.4 2.6 2.8 0.3 3.4 1.9 1.7 0.4 2.6 0.7 37 5 46 300 -15.8 0.3 -15.3 -16.5 12/03/2005 18:30:00 2.8 0.2 3.4 2.3 2.4 0.3 3.4 1.5 2 0.4 3 1.1 26 7 20 300 -15.3 0 -15.1 -15.5 12/03/2005 18:40:00 2.9 0.2 3.4 2.3 2.5 0.3 3 1.9 2.5 0.3 3.4 1.5 26 3 28 300 -16.3 0.5 -15.5 -16.9 12/03/2005 18:50:00 3 0.2 3.8 2.6 2.8 0.3 3.4 2.3 2.5 0.5 3.4 1.5 31 5 30 300 -16.2 0.2 -15.9 -16.9 12/03/2005 19:00:00 3.2 0.3 3.8 2.3 2.9 0.3 3.8 2.3 2.3 0.4 3.4 1.1 29 7 23 300 -15.9 0.1 -15.5 -16.1 12/03/2005 19:10:00 3.3 0.3 3.8 2.6 3 0.3 3.4 2.3 1.8 0.3 2.6 1.1 29 5 25 300 -16.3 0.3 -15.5 -16.7 12/03/2005 19:20:00 3.2 0.2 3.8 2.6 2.9 0.2 3.4 2.3 2 0.4 3 1.1 31 6 33 300 -16.3 0.4 -15.9 -17.1 12/03/2005 19:30:00 3.7 0.2 4.2 3 3.4 0.3 3.8 2.6 2.2 0.3 3.4 1.5 30 7 22 300 -16.9 0 -16.7 -17.1 12/03/2005 19:40:00 3.6 0.2 4.2 3 3.5 0.2 3.8 3 2.2 0.3 3.4 1.5 41 3 36 300 -16.2 0.3 -15.9 -16.9 12/03/2005 19:50:00 3.7 0.3 4.2 3 3.5 0.3 4.2 2.6 2.3 0.4 3.4 1.5 30 4 28 300 -16 0.1 -15.9 -16.3 12/03/2005 20:00:00 3.8 0.2 4.6 3 3.5 0.3 4.2 2.3 2.5 0.4 3.4 1.5 32 4 30 300 -16.2 0.1 -15.9 -16.5 12/03/2005 20:10:00 4.1 0.2 4.6 3.4 3.7 0.3 4.6 2.6 2.5 0.4 3.4 1.5 26 5 23 300 -16.6 0 -16.5 -16.7 12/03/2005 20:20:00 4.4 0.3 4.9 3.4 3.9 0.5 4.9 2.6 2.3 0.5 3.8 1.5 24 3 26 300 -16.7 0.1 -16.5 -17.1 12/03/2005 20:30:00 4.2 0.2 4.6 3.4 3.9 0.3 4.6 3 2.1 0.4 3 1.5 29 4 25 300 -16.2 0.3 -15.7 -16.7 12/03/2005 20:40:00 4.5 0.2 4.9 4.2 4.5 0.2 4.9 4.2 2.7 0.4 3.8 1.9 38 3 39 300 -15.8 0.1 -15.5 -15.9 12/03/2005 20:50:00 4.4 0.3 4.9 3.4 4.3 0.3 4.9 3 2.7 0.4 3.8 1.5 39 5 38 300 -15.6 0.1 -15.3 -15.9 12/03/2005 21:00:00 4.3 0.2 4.9 3.8 4.3 0.2 4.9 3.8 2.5 0.4 3.4 1.5 39 4 41 300 -15.6 0 -15.5 -15.9 12/03/2005 21:10:00 4.1 0.3 4.9 3.4 4 0.3 4.6 3.4 2.5 0.5 3.8 1.1 41 3 46 300 -15.6 0 -15.5 -15.9 12/03/2005 21:20:00 3.8 0.2 4.6 3 3.6 0.3 4.2 2.6 2.1 0.4 3.4 1.5 34 3 42 300 -15.4 0 -15.3 -15.5 12/03/2005 21:30:00 3.4 0.2 3.8 3 3.2 0.3 3.8 2.3 1.8 0.3 2.6 1.1 34 6 33 300 -15.6 0 -15.5 -15.9 12/03/2005 21:40:00 3.5 0.3 4.2 3 3 0.3 3.8 2.3 2.4 0.4 3 1.5 21 5 21 300 -15.9 0 -15.9 -16.3 12/03/2005 21:50:00 3.6 0.3 4.2 3 3.2 0.4 4.2 2.6 2.5 0.4 3.4 1.5 25 6 19 300 -16.3 0 -16.1 -16.5 12/03/2005 22:00:00 3.4 0.2 3.8 3 3 0.3 3.8 2.3 2.4 0.4 3.4 1.5 23 4 19 300 -16.2 0 -15.9 -16.5 12/03/2005 22:10:00 3.5 0.2 3.8 3 3.2 0.3 3.8 2.6 2 0.3 3.4 1.1 25 3 27 300 -16.3 0.1 -15.9 -16.5 12/03/2005 22:20:00 3.4 0.2 3.8 3 3 0.3 3.8 2.3 2.7 0.4 3.4 1.5 24 3 22 300 -16 0.2 -15.5 -16.5 12/03/2005 22:30:00 3 0.3 3.4 2.3 2.7 0.5 3.8 1.9 2.9 0.3 3.4 2.3 18 7 24 300 -16.1 0.1 -15.5 -16.3 12/03/2005 22:40:00 3.7 0.5 4.6 2.3 3.6 0.6 4.6 1.9 3 0.4 4.2 1.9 9 6 7 300 -16.2 0.2 -15.9 -16.5 12/03/2005 22:50:00 3.8 0.3 4.6 3 3.7 0.5 4.6 2.3 2.5 0.5 3.8 1.1 13 5 12 300 -16.2 0.1 -15.9 -16.5 12/03/2005 23:00:00 3.5 0.3 4.2 2.6 3 0.4 3.8 2.3 1.9 0.4 3 1.1 21 4 27 300 -16.6 0.2 -16.3 -16.9 12/03/2005 23:10:00 3.4 0.2 4.2 2.6 2.9 0.3 3.8 2.3 1.9 0.3 2.6 1.1 19 3 20 300 -16.5 0.1 -16.3 -17.1 12/03/2005 23:20:00 3.8 0.4 4.6 3 3.4 0.4 4.6 2.6 2.1 0.3 3 1.1 17 3 22 300 -17.6 0.3 -16.7 -18 12/03/2005 23:30:00 2.9 0.4 4.2 1.9 2.5 0.6 3.8 1.1 1.4 0.4 2.6 0.4 19 6 16 300 -17.9 0 -17.6 -18 12/03/2005 23:40:00 3.3 0.5 4.2 2.3 2.9 0.6 3.8 1.5 2 0.5 3 0.7 26 5 28 300 -18 0.1 -17.6 -18.2 12/03/2005 23:50:00 3.3 0.2 3.8 2.6 2.9 0.3 3.8 1.9 1.8 0.4 2.6 1.1 24 5 32 300 -18 0.5 -17.1 -18.5 12/04/2005 00:00:00 3.1 0.3 3.8 2.3 3 0.4 3.8 1.9 1.9 0.4 3 1.1 12 4 13 300 -17.1 0.1 -16.9 -17.4 12/04/2005 00:10:00 3.7 0.4 4.6 2.6 3.8 0.5 4.6 2.6 2.5 0.4 3.8 1.5 10 4 13 300 -17.5 0 -17.2 -17.6 12/04/2005 00:20:00 4.2 0.4 5.3 3 4 0.4 5.3 3 2.5 0.5 3.8 1.5 15 6 19 300 -17.7 0.1 -17.4 -18 12/04/2005 00:30:00 4.3 0.4 5.3 3 4.1 0.6 5.3 2.3 2.6 0.5 4.2 1.5 15 5 16 300 -17.8 0.1 -17.4 -18 12/04/2005 00:40:00 3.8 0.4 4.9 2.3 3.6 0.5 5.3 2.3 2.1 0.5 3.4 1.5 16 5 14 300 -16.8 0.2 -16.5 -17.4 12/04/2005 00:50:00 3.9 0.3 4.6 3 3.5 0.4 4.6 2.6 2.1 0.4 3 1.1 18 4 21 300 -16.4 0.1 -16.1 -16.7 12/04/2005 01:00:00 2.4 0.9 4.2 0.4 2 0.9 4.2 0.4 1 0.6 2.6 0.4 30 9 17 300 -16.5 0.3 -16.1 -17.2 12/04/2005 01:10:00 0.5 0.3 1.5 0.4 0.4 0.1 1.1 0.4 0.4 0 0.4 0.4 44 1 49 300 -17.9 0.4 -17.2 -18.5 12/04/2005 01:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 44 0 300 300 -19 0.1 -18.5 -19.1 12/04/2005 01:30:00 1.7 0.6 2.3 0.4 1.6 0.6 2.3 0.4 1.2 0.6 1.9 0.4 53 6 58 300 -19.1 0 -18.9 -19.1 12/04/2005 01:40:00 2.7 0.5 3.8 1.9 2.5 0.4 3.8 1.9 1.6 0.4 2.6 0.7 36 6 32 300 -18.8 0.3 -18.5 -19.1 12/04/2005 01:50:00 4 0.2 4.6 3.4 4 0.2 4.6 3.4 2.3 0.4 3 1.5 36 3 35 300 -18.2 0.4 -17.4 -18.5 12/04/2005 02:00:00 3.8 0.3 4.6 3 3.8 0.3 4.6 3 2.4 0.4 3.4 1.5 40 3 39 300 -17.4 0.1 -17.1 -17.4 12/04/2005 02:10:00 3.7 0.3 4.2 2.6 3.6 0.4 4.2 2.6 2.4 0.6 3.4 1.5 35 5 43 300 -17.1 0.3 -16.7 -17.4 12/04/2005 02:20:00 3.4 0.3 3.8 2.6 3.2 0.3 4.2 2.3 2.3 0.3 3 1.5 38 3 36 300 -17.5 0.4 -16.9 -18 12/04/2005 02:30:00 3.4 0.4 4.2 2.6 3.3 0.4 4.2 2.3 2.1 0.4 3 1.1 38 3 37 300 -17.5 0.3 -17.1 -18 12/04/2005 02:40:00 4.1 0.3 4.9 3 4 0.3 4.6 2.6 2.6 0.4 3.4 1.5 36 4 35 300 -17.3 0.1 -17.1 -17.4 12/04/2005 02:50:00 3.9 0.3 4.6 3 3.6 0.3 4.6 2.6 2 0.3 2.6 1.1 32 4 30 300 -16.9 0.1 -16.5 -17.1 12/04/2005 03:00:00 4 0.2 4.6 3.4 3.6 0.3 4.2 3 2.2 0.3 3.4 1.5 28 3 24 300 -16.8 0.1 -16.5 -17.1 12/04/2005 03:10:00 4 0.3 4.9 3 3.6 0.4 4.6 2.3 2.2 0.3 3.4 1.5 30 4 31 300 -17.4 0.1 -17.1 -17.4 12/04/2005 03:20:00 4 0.3 4.6 3.4 3.6 0.3 4.2 3 2.3 0.4 3.8 1.5 26 4 34 300 -16.9 0.1 -16.5 -17.1 12/04/2005 03:30:00 4.7 0.4 5.7 3.8 4.1 0.4 4.9 3.4 2.6 0.5 4.2 1.5 24 5 23 300 -16.6 0.2 -16.3 -17.1 12/04/2005 03:40:00 3.9 0.5 5.3 2.6 3.4 0.5 4.6 1.9 2 0.5 3.4 1.1 21 5 30 300 -17 0.1 -16.7 -17.1 12/04/2005 03:50:00 3.5 0.3 4.6 2.6 3 0.4 4.6 2.3 1.9 0.4 3 1.1 20 4 15 300 -16.8 0 -16.5 -17.1 12/04/2005 04:00:00 3.3 0.3 3.8 2.3 2.9 0.3 3.4 1.9 1.7 0.3 2.6 1.1 23 3 20 300 -16.6 0.1 -16.1 -16.9 12/04/2005 04:10:00 2.7 0.5 3.8 1.5 2.6 0.5 3.8 1.1 1.5 0.4 2.6 0.4 13 6 18 300 -16.5 0.2 -16.1 -16.9 12/04/2005 04:20:00 0.5 0.3 1.9 0.4 0.4 0.3 1.5 0.4 0.7 0.5 1.9 0.4 341 5 350 300 -18.2 1 -16.1 -19.3 12/04/2005 04:30:00 0.4 0.2 1.5 0.4 0.4 0.1 1.1 0.4 1.5 0.4 2.6 0.4 293 18 239 300 -19.8 0.2 -19.1 -20.2 12/04/2005 04:40:00 0.6 0.4 1.5 0.4 0.4 0.2 1.1 0.4 0.5 0.2 1.1 0.4 236 11 237 300 -20.3 0 -20 -20.5 12/04/2005 04:50:00 0.5 0.3 1.5 0.4 0.5 0.3 1.5 0.4 0.7 0.4 1.5 0.4 274 64 210 300 -20.7 0 -20.5 -20.7 12/04/2005 05:00:00 1.7 0.5 2.6 0.7 1.6 0.3 2.3 0.7 1.5 0.4 2.3 0.7 213 7 222 300 -20.5 0 -20.3 -20.7 12/04/2005 05:10:00 2.2 0.2 2.6 1.9 2 0.2 2.6 1.5 1.6 0.3 2.3 1.1 226 4 222 300 -20.3 0 -20.3 -20.5 12/04/2005 05:20:00 2.1 0.2 2.3 1.5 1.8 0.2 2.3 1.5 1.2 0.2 1.5 0.7 239 3 234 300 -20.4 0 -20.3 -20.5 12/04/2005 05:30:00 2.3 0.3 3 1.9 2.1 0.3 2.6 1.5 1.3 0.3 1.9 0.7 242 0 241 300 -20.7 0.1 -20.3 -20.9 12/04/2005 05:40:00 1.5 0.6 2.6 0.4 1.2 0.6 2.3 0.4 1.5 0.2 1.9 1.1 246 1 242 300 -20.5 0.1 -20.3 -20.9 12/04/2005 05:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.9 0.4 1.5 0.4 248 3 300 300 -20.8 0 -20.3 -20.9 12/04/2005 06:00:00 0.4 0.1 0.7 0.4 0.4 0 0.4 0.4 0.5 0.2 1.1 0.4 247 6 252 300 -20.9 0 -20.9 -21.1 12/04/2005 06:10:00 0.4 0.1 0.7 0.4 0.4 0 0.4 0.4 0.4 0.1 1.1 0.4 241 0 241 300 -21.5 0.2 -20.9 -21.8 12/04/2005 06:20:00 0.4 0 0.7 0.4 0.4 0 0.7 0.4 0.4 0 0.4 0.4 46 53 21 300 -21.8 0.2 -21.4 -22.1 12/04/2005 06:30:00 0.4 0.1 0.7 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 36 0 36 300 -21.6 0.1 -21.4 -21.8 12/04/2005 06:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 36 0 300 300 -21.8 0.1 -21.4 -21.9 12/04/2005 06:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.6 0.2 1.1 0.4 36 0 300 300 -21.5 0.1 -21.2 -21.6 12/04/2005 07:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 36 0 300 300 -21.1 0.2 -20.9 -21.6 12/04/2005 07:10:00 0.4 0.2 1.1 0.4 0.4 0.1 0.7 0.4 0.4 0 0.4 0.4 38 5 44 300 -21.9 0.5 -20.9 -22.5 12/04/2005 07:20:00 1.5 0.3 2.3 0.7 1.3 0.3 1.9 0.4 0.7 0.3 1.5 0.4 73 9 77 300 -22.2 0.2 -21.9 -22.6 12/04/2005 07:30:00 1.2 0.3 2.3 0.4 1.1 0.3 1.9 0.4 1 0.2 1.5 0.7 98 11 116 300 -22 0.2 -21.6 -22.3 12/04/2005 07:40:00 1 0.3 1.9 0.4 0.8 0.4 1.5 0.4 0.6 0.4 1.5 0.4 112 8 114 300 -21.7 0.2 -21.4 -21.8 12/04/2005 07:50:00 1.1 0.2 1.5 0.7 0.9 0.2 1.5 0.4 0.6 0.3 1.5 0.4 101 2 105 300 -21.7 0.1 -21.4 -21.8 12/04/2005 08:00:00 1.1 0.2 1.5 0.7 0.9 0.3 1.5 0.4 1 0.2 1.5 0.4 101 3 98 300 -21.5 0.2 -21.2 -22.1 12/04/2005 08:10:00 0.9 0.3 1.5 0.4 0.7 0.3 1.5 0.4 0.5 0.2 1.1 0.4 106 7 94 300 -21.5 0.5 -20.7 -22.3 12/04/2005 08:20:00 1 0.3 1.5 0.4 0.7 0.3 1.5 0.4 0.7 0.2 1.1 0.4 109 17 97 300 -21.2 0.2 -20.7 -21.6 12/04/2005 08:30:00 1.6 0.2 2.3 1.1 1.4 0.2 1.9 0.7 1.1 0.3 1.5 0.4 133 3 129 300 -21 0.2 -20.7 -21.6 12/04/2005 08:40:00 1.2 0.4 1.9 0.4 1 0.4 1.9 0.4 0.8 0.2 1.1 0.4 136 1 138 300 -21.8 0.1 -21.6 -21.9 12/04/2005 08:50:00 0.7 0.2 1.1 0.4 0.4 0.1 0.7 0.4 0.7 0.2 1.1 0.4 157 17 135 300 -21.3 0.2 -20.7 -21.6 12/04/2005 09:00:00 0.5 0.2 1.1 0.4 0.4 0 0.4 0.4 0.5 0.2 1.1 0.4 193 2 193 300 -20.3 0.1 -20.2 -20.7 12/04/2005 09:10:00 1.3 0.3 1.9 0.7 1.4 0.3 1.9 0.4 1.4 0.2 1.5 0.7 208 5 209 300 -20.7 0.1 -20.3 -20.9 12/04/2005 09:20:00 1.7 0.2 2.3 0.7 1.5 0.2 1.9 1.1 1.5 0.2 1.9 1.1 230 11 240 300 -20 0 -19.8 -20.3 12/04/2005 09:30:00 1.6 0.3 2.3 1.1 1.4 0.3 1.9 0.7 1.2 0.2 1.9 0.7 238 1 240 300 -20.2 0.1 -19.8 -20.5 12/04/2005 09:40:00 1.1 0.2 1.5 0.7 0.8 0.2 1.1 0.4 0.8 0.2 1.1 0.4 240 5 238 300 -20.5 0.1 -20.3 -20.9 12/04/2005 09:50:00 1.4 0.3 1.9 0.7 1.1 0.3 1.5 0.4 0.8 0.3 1.5 0.4 256 1 256 300 -21.1 0.2 -20.7 -21.4 12/04/2005 10:00:00 1.1 0.2 1.5 0.7 0.8 0.2 1.5 0.4 0.9 0.2 1.1 0.4 263 1 261 300 -21.5 0.4 -20.9 -22.3 12/04/2005 10:10:00 0.9 0.3 1.5 0.4 0.6 0.3 1.1 0.4 0.6 0.3 1.1 0.4 263 0 264 300 -22.2 0.2 -21.9 -22.5 12/04/2005 10:20:00 0.4 0 0.7 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 263 0 264 300 -22.8 0.3 -22.5 -23.5 12/04/2005 10:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 263 0 300 300 -22.2 0.7 -21.2 -23.5 12/04/2005 10:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 263 0 300 300 -21.9 0.1 -21.6 -22.3 12/04/2005 10:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 263 0 300 300 -21.4 0.2 -20.9 -21.8 12/04/2005 11:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 263 0 300 300 -22.5 0.3 -21.8 -23 12/04/2005 11:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 262 9 300 300 -22.4 0.1 -21.9 -22.6 12/04/2005 11:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0.1 0.7 0.4 172 4 300 300 -22.2 0.2 -21.9 -22.6 12/04/2005 11:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 171 0 300 300 -21.6 0.3 -20.9 -21.9 12/04/2005 11:40:00 0.4 0.1 0.7 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 218 13 222 300 -20.7 0.3 -20.2 -21.1 12/04/2005 11:50:00 0.6 0.3 1.1 0.4 0.4 0.1 1.1 0.4 0.4 0 0.4 0.4 222 0 222 300 -19.6 0.2 -19.3 -20.2 12/04/2005 12:00:00 0.6 0.2 1.1 0.4 0.4 0.1 0.7 0.4 0.4 0.1 1.1 0.4 221 1 222 300 -19.1 0.3 -18.5 -19.6 12/04/2005 12:10:00 0.9 0.4 1.5 0.4 0.9 0.5 1.5 0.4 1 0.4 1.9 0.4 219 2 218 300 -18.1 0.3 -17.4 -18.5 12/04/2005 12:20:00 1.3 0.2 1.5 0.7 1 0.2 1.5 0.4 0.8 0.4 1.5 0.4 223 0 223 300 -17 0.1 -16.7 -17.4 12/04/2005 12:30:00 1 0.2 1.5 0.4 0.7 0.3 1.1 0.4 0.5 0.2 1.1 0.4 231 4 224 300 -17 0.3 -16.5 -17.4 12/04/2005 12:40:00 0.9 0.3 1.5 0.4 0.6 0.3 1.1 0.4 0.4 0.2 1.1 0.4 224 13 233 300 -16 0.2 -15.9 -16.5 12/04/2005 12:50:00 1.2 0.4 1.9 0.4 1.1 0.2 1.5 0.7 0.9 0.4 1.9 0.4 196 2 196 300 -16.6 0.4 -15.9 -17.4 12/04/2005 13:00:00 0.9 0.5 1.9 0.4 0.7 0.4 1.5 0.4 0.7 0.4 1.5 0.4 190 3 195 300 -17.5 0 -17.4 -17.4 12/04/2005 13:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 188 0 300 300 -17.5 0 -17.2 -17.8 12/04/2005 13:20:00 0.5 0.2 0.7 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 188 0 188 300 -17.7 0 -17.4 -17.8 12/04/2005 13:30:00 0.8 0.4 1.5 0.4 0.6 0.4 1.5 0.4 0.6 0.3 1.1 0.4 168 16 169 300 -18.1 0.2 -17.4 -18.5 12/04/2005 13:40:00 0.4 0 0.7 0.4 0.4 0 0.4 0.4 0.4 0 0.7 0.4 151 0 151 300 -18.8 0.1 -18.4 -18.9 12/04/2005 13:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 151 0 300 300 -18.9 0 -18.7 -18.9 12/04/2005 14:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 151 0 300 300 -18.7 0 -18.5 -18.9 12/04/2005 14:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 151 0 300 300 -18.9 0 -18.5 -19.1 12/04/2005 14:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 151 0 300 300 -19.3 0.1 -18.9 -19.4 12/04/2005 14:30:00 0.4 0.2 1.5 0.4 0.4 0.1 1.1 0.4 0.4 0 0.4 0.4 211 43 246 300 -19.3 0 -19.1 -19.4 12/04/2005 14:40:00 1.2 0.3 1.9 0.7 0.8 0.3 1.5 0.4 0.5 0.2 1.1 0.4 246 1 249 300 -19.2 0 -19.1 -19.1 12/04/2005 14:50:00 1.1 0.2 1.5 0.4 0.8 0.3 1.5 0.4 0.4 0.1 0.7 0.4 249 0 249 300 -19.4 0.2 -19.1 -19.8 12/04/2005 15:00:00 1 0.3 1.9 0.4 0.7 0.3 1.5 0.4 0.8 0.2 1.1 0.4 238 7 237 300 -19.5 0.2 -19.1 -19.8 12/04/2005 15:10:00 1.1 0.3 1.9 0.4 0.8 0.3 1.5 0.4 0.8 0.3 1.5 0.4 242 8 240 300 -19.5 0.1 -19.1 -19.8 12/04/2005 15:20:00 2 0.5 3 0.7 1.9 0.5 2.6 0.4 1.2 0.5 1.9 0.4 266 4 258 300 -19.8 0 -19.6 -20 12/04/2005 15:30:00 2.5 0.3 3.4 1.9 2.3 0.4 3 1.5 1.8 0.3 2.6 0.7 261 6 258 300 -20.4 0.1 -19.8 -20.7 12/04/2005 15:40:00 2 0.2 2.6 1.5 1.8 0.2 2.6 1.1 1.5 0.4 2.3 0.7 253 3 252 300 -20.9 0.2 -20.5 -21.1 12/04/2005 15:50:00 1.6 0.2 1.9 1.1 1.3 0.2 1.9 0.7 0.8 0.4 1.5 0.4 244 8 258 300 -20.9 0.1 -20.7 -21.2 12/04/2005 16:00:00 1 0.3 1.5 0.4 0.6 0.3 1.1 0.4 0.4 0 0.4 0.4 243 3 240 300 -21.2 0 -20.9 -21.4 12/04/2005 16:10:00 0.8 0.4 1.5 0.4 0.5 0.3 1.5 0.4 0.4 0.1 1.1 0.4 252 11 239 300 -21.3 0.2 -20.9 -21.6 12/04/2005 16:20:00 0.4 0.1 1.1 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 252 2 261 300 -20.9 0 -20.9 -21.1 12/04/2005 16:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 251 0 300 300 -20.9 0.1 -20.7 -21.1 12/04/2005 16:40:00 0.4 0.2 0.7 0.4 0.4 0 0.4 0.4 0.5 0.2 1.1 0.4 278 22 297 300 -20.9 0 -20.9 -21.1 12/04/2005 16:50:00 0.4 0 0.7 0.4 0.4 0 0.4 0.4 0.5 0.3 1.1 0.4 308 0 307 300 -20.7 0.2 -20.3 -20.9 12/04/2005 17:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.6 0.4 1.9 0.4 303 66 300 300 -20.4 0.1 -20.3 -20.7 12/04/2005 17:10:00 0.4 0 0.7 0.4 0.4 0 0.4 0.4 1.5 0.3 1.9 0.4 47 18 35 300 -20.4 0.1 -20 -20.5 12/04/2005 17:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.9 0.4 1.9 0.4 37 0 300 300 -19.7 0.1 -19.4 -20 12/04/2005 17:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.7 0.4 37 0 300 300 -19.3 0.1 -19.1 -19.8 12/04/2005 17:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0.2 1.5 0.4 37 0 300 300 -19.4 0 -19.1 -19.6 12/04/2005 17:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 1 0.3 1.5 0.4 53 20 300 300 -19.4 0.2 -19.1 -19.8 12/04/2005 18:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0.2 1.1 0.4 108 19 300 300 -19.4 0.2 -19.1 -19.8 12/04/2005 18:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 167 0 300 300 -19 0.1 -18.5 -19.1 12/04/2005 18:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.7 0.4 1.5 0.4 74 43 300 300 -18.6 0 -18.5 -18.7 12/04/2005 18:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 87 38 300 300 -18.3 0.2 -18 -18.5 12/04/2005 18:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 122 0 300 300 -18.2 0 -18 -18.4 12/04/2005 18:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 122 0 300 300 -18.1 0 -18 -18.4 12/04/2005 19:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 122 0 300 300 -18.1 0 -18 -18.2 12/04/2005 19:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 121 2 300 300 -18.2 0 -18 -18.4 12/04/2005 19:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 108 0 300 300 -18.1 0 -18 -18.2 12/04/2005 19:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 75 4 300 300 -17.9 0 -17.8 -18 12/04/2005 19:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 83 13 300 300 -17.7 0.1 -17.4 -17.8 12/04/2005 19:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 129 39 300 300 -17.5 0 -17.4 -17.4 12/04/2005 20:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 214 23 300 300 -17.6 0 -17.4 -17.6 12/04/2005 20:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 233 0 300 300 -17.5 0 -17.4 -17.6 12/04/2005 20:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 233 0 300 300 -17.2 0 -17.1 -17.4 12/04/2005 20:30:00 0.5 0.3 1.5 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 221 7 231 300 -17.1 0.1 -17.1 -17.4 12/04/2005 20:40:00 0.5 0.3 1.5 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 234 1 230 300 -17.2 0 -17.1 -17.4 12/04/2005 20:50:00 0.4 0.2 0.7 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 245 9 248 300 -17.1 0 -17.1 -17.1 12/04/2005 21:00:00 0.4 0.1 0.7 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 264 3 264 300 -17.1 0 -17.1 -17.2 12/04/2005 21:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 259 11 300 300 -17 0 -17.1 -17.1 12/04/2005 21:20:00 0.4 0.1 1.1 0.4 0.4 0 0.4 0.4 0.4 0.2 1.1 0.4 240 27 195 300 -16.9 0 -16.7 -17.1 12/04/2005 21:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 283 17 300 300 -16.8 0 -16.5 -16.9 12/04/2005 21:40:00 0.4 0.1 0.7 0.4 0.4 0 0.7 0.4 0.4 0.2 1.5 0.4 348 15 359 300 -16.7 0 -16.5 -16.9 12/04/2005 21:50:00 0.6 0.4 1.5 0.4 0.5 0.2 1.5 0.4 1.1 0.3 1.9 0.4 42 17 53 300 -16.6 0.1 -16.3 -16.9 12/04/2005 22:00:00 0.6 0.4 1.9 0.4 0.5 0.3 1.5 0.4 0.7 0.3 1.5 0.4 85 17 56 300 -16.2 0 -16.1 -16.5 12/04/2005 22:10:00 0.4 0 0.7 0.4 0.4 0 0.4 0.4 0.4 0.2 1.1 0.4 82 6 86 300 -16.1 0 -15.9 -16.1 12/04/2005 22:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0.2 1.1 0.4 58 13 300 300 -15.9 0 -15.9 -15.9 12/04/2005 22:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.7 0.4 91 21 300 300 -15.8 0 -15.5 -15.9 12/04/2005 22:40:00 0.5 0.3 1.5 0.4 0.5 0.3 1.5 0.4 0.4 0.1 0.7 0.4 85 21 57 300 -15.5 0.1 -15.3 -15.7 12/04/2005 22:50:00 0.4 0.1 0.7 0.4 0.4 0 0.7 0.4 0.4 0 0.4 0.4 108 13 128 300 -15.2 0 -15 -15.3 12/04/2005 23:00:00 1.2 0.6 2.3 0.4 1.2 0.5 2.3 0.4 1 0.5 1.9 0.4 94 8 98 300 -15.1 0 -15 -15.1 12/04/2005 23:10:00 1.7 0.3 2.3 0.7 1.6 0.3 2.3 1.1 1.2 0.4 2.3 0.4 85 14 100 300 -15.1 0 -15 -15.1 12/04/2005 23:20:00 1.3 0.4 2.3 0.4 1.2 0.4 1.9 0.4 1 0.4 1.9 0.4 49 11 60 300 -14.8 0 -14.8 -15 12/04/2005 23:30:00 1.8 0.4 2.6 0.7 1.7 0.4 2.6 0.7 1 0.5 2.3 0.4 56 11 56 300 -14.7 0.1 -14.6 -14.8 12/04/2005 23:40:00 1.9 0.4 3 1.1 1.8 0.4 2.6 0.7 0.9 0.4 1.9 0.4 53 11 34 300 -14.4 0 -14.2 -14.6 12/04/2005 23:50:00 2.3 0.7 4.2 0.7 2.2 0.7 4.2 0.4 1.2 0.5 2.3 0.4 53 16 37 300 -14 0 -14 -14.2 12/05/2005 00:00:00 1.9 0.6 3.8 0.4 1.8 0.7 3.4 0.4 1 0.5 2.3 0.4 65 16 62 300 -13.8 0.1 -13.4 -14 12/05/2005 00:10:00 1.4 0.5 2.6 0.4 1.4 0.6 2.3 0.4 0.9 0.5 2.3 0.4 94 22 79 300 -13.4 0 -13.4 -13.6 12/05/2005 00:20:00 2.2 0.4 3 1.1 2.2 0.4 3 0.7 1.4 0.5 2.3 0.4 81 35 92 300 -13.4 0 -13.2 -13.6 12/05/2005 00:30:00 1.4 0.6 3 0.4 1.4 0.6 3 0.4 0.9 0.5 2.3 0.4 93 24 116 300 -13.2 0 -13.2 -13.4 12/05/2005 00:40:00 1.1 0.4 1.9 0.4 1 0.4 1.9 0.4 0.7 0.4 1.5 0.4 93 22 101 300 -13.2 0 -13.2 -13.2 12/05/2005 00:50:00 0.8 0.5 2.3 0.4 0.8 0.5 1.9 0.4 0.5 0.3 1.5 0.4 98 29 105 300 -13.1 0 -13 -13.2 12/05/2005 01:00:00 0.4 0.1 1.1 0.4 0.4 0.1 1.1 0.4 0.4 0 0.4 0.4 136 24 129 300 -12.9 0 -12.8 -13.2 12/05/2005 01:10:00 0.4 0 0.7 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 166 13 178 300 -13.1 0 -13 -13.2 12/05/2005 01:20:00 0.4 0.1 1.1 0.4 0.4 0.1 0.7 0.4 0.4 0.1 0.7 0.4 196 21 177 300 -13.1 0 -13.2 -13.2 12/05/2005 01:30:00 0.4 0.1 0.7 0.4 0.4 0 0.7 0.4 0.4 0.1 0.7 0.4 215 9 203 300 -13.2 0 -13.2 -13.4 12/05/2005 01:40:00 0.4 0.1 1.1 0.4 0.4 0.1 1.1 0.4 0.4 0 0.4 0.4 146 69 194 300 -13.2 0 -13.2 -13.4 12/05/2005 01:50:00 0.6 0.4 2.3 0.4 0.5 0.4 2.6 0.4 0.4 0.2 1.1 0.4 63 61 36 300 -13.1 0 -13.2 -13.2 12/05/2005 02:00:00 1.6 0.7 3.4 0.4 1.5 0.7 3.8 0.4 0.7 0.5 2.3 0.4 49 38 49 300 -13.1 0 -13.2 -13.2 12/05/2005 02:10:00 1.3 0.9 4.2 0.4 1.1 0.8 4.2 0.4 0.6 0.5 3 0.4 60 45 16 300 -13.1 0 -13.2 -13.2 12/05/2005 02:20:00 3.2 1.2 6.1 1.1 3 1.2 6.5 0.4 1.7 1 4.6 0.4 41 23 35 300 -12.8 0.3 -12 -13.2 12/05/2005 02:30:00 4.3 1.3 7.6 0.7 4 1.3 7.6 0.7 2.8 1 5.3 0.4 45 19 42 300 -11.5 1 -9.7 -12.6 12/05/2005 02:40:00 5.4 1.5 9.1 0.7 5 1.5 8.8 1.1 3.8 1.1 6.5 1.1 35 20 12 300 -9.6 0.4 -8.9 -10.2 12/05/2005 02:50:00 7 1.3 10.3 3.4 6.5 1.3 9.5 3 5.2 1.3 8 1.5 28 15 11 300 -8.8 0 -8.7 -8.9 12/05/2005 03:00:00 6.6 1.4 9.9 2.6 6 1.5 9.1 2.3 4.9 1.3 7.6 1.9 28 15 24 300 -8.7 0 -8.5 -8.7 12/05/2005 03:10:00 7.1 1.3 11.1 3.4 6.4 1.3 10.3 3 5.3 1.2 9.5 2.6 27 15 19 300 -8.5 0 -8.3 -8.7 12/05/2005 03:20:00 7.7 1.5 11.5 3.8 6.9 1.5 11.1 3.8 5.6 1.3 9.1 1.9 26 13 19 300 -8.3 0 -8.1 -8.5 12/05/2005 03:30:00 8.8 1.5 12.6 4.9 7.8 1.5 11.8 4.2 6.5 1.4 11.5 3 26 11 22 300 -8.3 0 -8.1 -8.5 12/05/2005 03:40:00 9.1 1.6 13 4.2 8.2 1.5 13 3.8 6.5 1.6 11.5 3.4 22 12 28 300 -8.2 0 -8.1 -8.3 12/05/2005 03:50:00 7.6 1.6 11.5 3.4 6.9 1.6 10.7 3.4 5.8 1.4 9.9 2.3 24 11 20 300 -8.1 0 -8.1 -8.1 12/05/2005 04:00:00 7.4 1.7 11.5 3.4 6.7 1.6 11.1 3 5.5 1.6 10.3 1.9 27 15 24 300 -8 0 -7.9 -8.1 12/05/2005 04:10:00 7.6 1.5 12.2 2.3 6.9 1.4 11.1 1.9 5.5 1.2 8.8 2.6 29 15 22 300 -8 0 -7.9 -8.1 12/05/2005 04:20:00 7.9 1.6 11.8 3.8 7.2 1.6 11.8 3 6.1 1.5 11.1 2.6 24 15 17 300 -7.9 0 -7.6 -8.1 12/05/2005 04:30:00 7.9 1.7 12.2 4.2 7.3 1.7 12.6 3.4 6 1.6 12.2 2.6 24 16 4 300 -7.7 0 -7.6 -7.9 12/05/2005 04:40:00 8 1.3 11.8 4.6 7.3 1.4 10.7 3.8 5.9 1.3 9.9 3 30 13 28 300 -7.6 0 -7.4 -7.6 12/05/2005 04:50:00 8.3 1.5 13 2.6 7.7 1.4 11.8 3 6.2 1.3 11.1 3 24 15 17 300 -7.5 0 -7.4 -7.6 12/05/2005 05:00:00 8.3 1.6 12.2 4.6 7.5 1.5 11.8 3.8 6.3 1.5 10.7 2.6 25 13 19 300 -7.5 0 -7.2 -7.4 12/05/2005 05:10:00 8.3 1.6 12.2 2.6 7.5 1.6 11.5 2.3 6.1 1.5 10.7 1.9 24 12 19 300 -7.5 0 -7.2 -7.4 12/05/2005 05:20:00 8 1.4 11.5 4.6 7.3 1.4 11.1 4.2 5.9 1.3 9.9 2.6 25 14 14 300 -7.3 0 -7.2 -7.4 12/05/2005 05:30:00 7.7 1.4 11.1 4.2 7.1 1.4 11.1 3.8 5.9 1.3 10.3 2.6 28 13 31 300 -7.2 0 -7.2 -7.2 12/05/2005 05:40:00 7.4 1.4 10.7 3.8 6.7 1.4 9.9 3 5.4 1.3 8.8 1.9 27 13 22 300 -7.2 0 -7.2 -7.2 12/05/2005 05:50:00 7.4 1.4 11.5 4.2 6.8 1.4 11.1 3 5.6 1.2 8.8 3 28 13 40 300 -7.1 0 -7 -7.2 12/05/2005 06:00:00 8.5 1.3 11.1 4.9 7.7 1.3 11.5 4.2 6.3 1.4 10.7 2.6 23 11 13 300 -7.1 0 -7 -7.2 12/05/2005 06:10:00 8.2 1.5 11.5 4.2 7.4 1.5 11.5 3.8 6.1 1.3 9.9 3 28 13 31 300 -7.2 0 -7 -7.2 12/05/2005 06:20:00 8.1 1.6 12.2 4.2 7.3 1.5 11.5 3.4 5.9 1.5 11.1 2.6 26 12 20 300 -7.1 0 -7 -7.2 12/05/2005 06:30:00 7.9 1.5 11.1 4.6 7.2 1.5 10.7 3.8 5.7 1.4 9.5 2.3 26 14 25 300 -7.1 0 -7 -7.2 12/05/2005 06:40:00 8.1 1.7 11.8 3 7.4 1.5 11.5 3.4 6 1.3 9.5 2.6 27 13 25 300 -7.1 0 -7 -7.2 12/05/2005 06:50:00 7.8 1.4 11.5 3.8 7.1 1.5 10.7 3.8 5.8 1.3 9.1 2.6 26 12 41 300 -7.1 0 -7 -7.2 12/05/2005 07:00:00 7.5 1.6 11.8 1.9 6.9 1.7 11.1 1.5 5.8 1.4 9.1 1.9 24 15 20 300 -6.9 0.1 -6.8 -7 12/05/2005 07:10:00 7.3 1.2 11.1 4.2 6.6 1.2 10.7 3.8 5.5 1.1 9.1 2.3 26 13 53 300 -6.7 0 -6.6 -6.8 12/05/2005 07:20:00 7.7 1.5 11.8 4.2 7 1.3 11.1 3.4 5.8 1.3 9.9 2.3 26 13 30 300 -6.6 0 -6.6 -6.8 12/05/2005 07:30:00 6.6 1.5 9.9 3 6.1 1.5 10.3 2.6 5.2 1.3 8.8 2.6 30 17 33 300 -6.6 0 -6.6 -6.8 12/05/2005 07:40:00 5.1 1.6 9.5 1.5 4.8 1.5 9.9 0.7 3.9 1.5 7.6 1.1 34 24 359 300 -6.5 0 -6.6 -6.6 12/05/2005 07:50:00 4 1.5 9.9 0.7 4 1.5 9.9 0.7 3.3 1.5 9.1 0.4 51 27 45 300 -6.4 0 -6.1 -6.6 12/05/2005 08:00:00 3.1 1.1 6.5 0.4 3.1 1.1 6.5 0.4 2.8 0.8 5.7 1.1 60 27 56 300 -6.4 0 -6.1 -6.6 12/05/2005 08:10:00 3.3 1 6.1 1.1 3.2 1.1 6.1 0.4 3 0.9 5.3 1.1 60 24 88 300 -6.4 0 -6.4 -6.6 12/05/2005 08:20:00 2.6 0.8 4.9 0.4 2.6 0.9 4.6 0.4 2.5 0.7 4.2 0.7 78 27 109 300 -6.5 0 -6.4 -6.6 12/05/2005 08:30:00 2.6 1 4.9 0.4 2.6 1.1 6.1 0.4 2.2 1 4.9 0.4 77 26 8 300 -6.5 0 -6.4 -6.6 12/05/2005 08:40:00 2.3 1 4.6 0.4 2.3 1 4.9 0.4 1.9 0.9 4.6 0.4 88 23 38 300 -6.7 0.1 -6.6 -7 12/05/2005 08:50:00 1.6 0.6 3 0.4 1.5 0.6 3 0.4 1.5 0.6 3 0.4 141 36 100 300 -7 0 -6.8 -7.2 12/05/2005 09:00:00 0.9 0.6 3 0.4 0.8 0.6 3 0.4 0.8 0.5 2.3 0.4 153 28 141 300 -7.3 0 -7 -7.2 12/05/2005 09:10:00 0.9 0.6 3 0.4 0.8 0.6 2.6 0.4 0.7 0.5 3 0.4 134 117 305 300 -7.3 0 -7.2 -7.4 12/05/2005 09:20:00 1 0.7 2.6 0.4 0.9 0.7 3 0.4 1 0.6 2.6 0.4 121 72 29 300 -7.2 0 -7 -7.2 12/05/2005 09:30:00 1.2 0.7 3 0.4 1.2 0.7 3 0.4 1.4 0.5 3 0.4 139 35 88 300 -7.4 0.1 -7.2 -7.6 12/05/2005 09:40:00 2.4 0.6 3.8 0.7 2.4 0.6 3.8 1.1 2.2 0.5 3.4 0.4 180 12 229 300 -7.6 0 -7.4 -7.6 12/05/2005 09:50:00 2.1 0.5 3.4 0.7 2 0.5 3.4 1.1 1.9 0.5 3 0.4 201 15 187 300 -7.7 0 -7.6 -7.6 12/05/2005 10:00:00 2.1 0.5 3.4 0.7 2.3 0.5 3.4 0.7 2 0.4 3 1.1 215 7 218 300 -7.6 0 -7.4 -7.6 12/05/2005 10:10:00 1.9 0.5 3 0.4 2 0.6 3 0.4 1.9 0.6 3 0.4 212 11 221 300 -7.6 0 -7.4 -7.6 12/05/2005 10:20:00 1.1 0.6 2.6 0.4 1 0.7 2.6 0.4 1.2 0.7 2.6 0.4 203 19 193 300 -7.6 0 -7.4 -7.6 12/05/2005 10:30:00 1.9 0.6 3.4 0.7 1.9 0.6 3.4 0.7 1.9 0.7 3.4 0.4 215 14 218 300 -7.5 0 -7.4 -7.6 12/05/2005 10:40:00 1.7 0.6 3 0.4 1.8 0.8 3 0.4 1.7 0.7 2.6 0.4 203 14 227 300 -7.5 0 -7.2 -7.6 12/05/2005 10:50:00 1.5 0.6 2.6 0.4 1.6 0.6 2.6 0.4 1.5 0.6 2.6 0.4 208 11 225 300 -7.4 0 -7.2 -7.4 12/05/2005 11:00:00 1.9 0.4 3 1.1 2 0.4 3 0.7 1.7 0.6 2.6 0.4 205 12 200 300 -7.4 0 -7.2 -7.4 12/05/2005 11:10:00 1.4 0.6 3 0.4 1.4 0.6 2.6 0.4 1.6 0.6 3 0.4 203 21 219 300 -7.3 0 -7.2 -7.4 12/05/2005 11:20:00 1 0.7 3 0.4 1 0.7 3 0.4 1.1 0.7 3 0.4 176 22 189 300 -7.3 0 -7.2 -7.2 12/05/2005 11:30:00 0.6 0.4 1.5 0.4 0.6 0.3 1.5 0.4 0.9 0.5 2.3 0.4 179 10 158 300 -7.3 0 -7.2 -7.2 12/05/2005 11:40:00 1.2 1 3.4 0.4 1.2 1 3 0.4 1.1 0.8 2.6 0.4 171 41 191 300 -7.2 0 -7.2 -7.2 12/05/2005 11:50:00 1.4 0.6 2.6 0.4 1.5 0.6 2.6 0.4 1.7 0.4 2.6 0.4 198 17 172 300 -7.2 0 -7.2 -7.2 12/05/2005 12:00:00 2.2 0.6 3.8 0.7 2.8 0.6 3.8 1.1 2.5 0.6 3.8 1.1 212 8 229 300 -7.1 0 -7 -7.2 12/05/2005 12:10:00 2.5 0.7 4.2 0.7 2.5 0.6 4.2 0.7 2.2 0.8 4.2 0.7 222 8 227 300 -7.1 0 -7 -7 12/05/2005 12:20:00 2 0.8 3.8 0.4 2 0.7 4.2 0.4 1.7 0.7 3.4 0.4 223 11 233 300 -7 0 -6.8 -7 12/05/2005 12:30:00 1.7 0.5 3 0.4 1.9 0.6 3 0.7 1.9 0.6 3.4 0.4 212 11 208 300 -6.8 0 -6.8 -7 12/05/2005 12:40:00 1.9 0.8 3 0.4 2.1 0.8 3.8 0.4 1.8 0.9 3.4 0.4 217 14 229 300 -6.7 0 -6.6 -6.8 12/05/2005 12:50:00 1.5 0.7 3 0.4 1.6 0.7 3 0.4 1.6 0.6 3 0.4 216 13 226 300 -6.6 0 -6.6 -6.8 12/05/2005 13:00:00 0.7 0.4 2.3 0.4 0.8 0.4 2.3 0.4 1 0.4 1.9 0.4 210 24 213 300 -6.5 0 -6.6 -6.6 12/05/2005 13:10:00 1.3 0.5 2.3 0.4 1.4 0.5 2.3 0.4 1.3 0.5 2.3 0.4 210 15 218 300 -6.7 0 -6.6 -6.8 12/05/2005 13:20:00 0.7 0.3 1.9 0.4 0.8 0.4 1.5 0.4 0.9 0.4 1.5 0.4 210 11 188 300 -6.8 0 -6.6 -6.8 12/05/2005 13:30:00 0.8 0.4 1.9 0.4 0.8 0.4 1.9 0.4 0.8 0.4 1.9 0.4 227 10 218 300 -6.7 0 -6.6 -6.8 12/05/2005 13:40:00 0.4 0.1 1.1 0.4 0.4 0.1 1.1 0.4 0.4 0.1 1.1 0.4 213 22 233 300 -6.5 0 -6.6 -6.8 12/05/2005 13:50:00 0.4 0.1 0.7 0.4 0.4 0.1 0.7 0.4 0.4 0.2 1.1 0.4 252 17 224 300 -6.5 0 -6.4 -6.6 12/05/2005 14:00:00 0.4 0.1 1.1 0.4 0.4 0.2 1.1 0.4 0.7 0.4 1.5 0.4 218 29 187 300 -6.4 0 -6.1 -6.6 12/05/2005 14:10:00 0.6 0.4 1.9 0.4 0.7 0.4 1.9 0.4 0.9 0.4 1.9 0.4 226 16 219 300 -6.4 0 -6.1 -6.6 12/05/2005 14:20:00 0.4 0.2 1.1 0.4 0.5 0.3 1.5 0.4 0.8 0.4 1.9 0.4 204 23 201 300 -6.4 0 -6.1 -6.6 12/05/2005 14:30:00 1 0.8 2.6 0.4 1.1 0.8 2.6 0.4 1.4 0.6 2.6 0.4 186 39 221 300 -6.5 0 -6.1 -6.6 12/05/2005 14:40:00 2.2 0.4 3.4 1.5 2.3 0.4 3.4 1.5 2 0.5 3 0.7 226 11 234 300 -6.5 0 -6.4 -6.6 12/05/2005 14:50:00 1.9 0.6 3.4 0.4 1.9 0.7 3 0.4 1.7 0.7 3 0.4 242 18 249 300 -6.4 0 -6.4 -6.6 12/05/2005 15:00:00 1.7 0.6 3 0.4 1.7 0.6 3 0.4 1.6 0.6 3 0.7 221 22 221 300 -6.4 0 -6.1 -6.4 12/05/2005 15:10:00 1.2 0.5 2.6 0.4 1.2 0.6 2.6 0.4 1.2 0.6 2.6 0.4 196 13 181 300 -6.2 0 -6.1 -6.4 12/05/2005 15:20:00 0.8 0.6 2.3 0.4 0.8 0.5 2.3 0.4 0.9 0.5 2.3 0.4 169 30 166 300 -6.2 0 -6.1 -6.4 12/05/2005 15:30:00 1.2 0.6 2.6 0.4 1.2 0.6 2.6 0.4 1.2 0.6 2.6 0.4 201 26 197 300 -6.3 0 -6.1 -6.4 12/05/2005 15:40:00 0.5 0.3 1.5 0.4 0.5 0.3 1.5 0.4 0.5 0.3 1.9 0.4 216 20 216 300 -6.4 0 -6.1 -6.4 12/05/2005 15:50:00 1 0.5 2.3 0.4 1.1 0.7 3 0.4 1 0.6 2.6 0.4 221 13 206 300 -6.2 0 -6.1 -6.4 12/05/2005 16:00:00 1.3 0.6 2.6 0.4 1.3 0.6 2.6 0.4 1.2 0.5 2.3 0.4 210 22 205 300 -6.2 0 -6.1 -6.4 12/05/2005 16:10:00 2.1 0.5 3 0.4 2.2 0.5 3 0.4 1.9 0.5 3 0.4 224 17 200 300 -6.2 0 -6.1 -6.1 12/05/2005 16:20:00 2.4 0.6 3.8 0.4 2.3 0.6 3.4 0.4 2 0.5 3.4 0.7 225 18 234 300 -6.1 0 -5.9 -6.1 12/05/2005 16:30:00 1.6 0.5 2.6 0.4 1.6 0.6 3 0.4 1.5 0.6 2.6 0.4 223 32 213 300 -6 0 -5.9 -6.1 12/05/2005 16:40:00 1.7 1 3.8 0.4 1.7 1 3.8 0.4 1.7 0.9 3.4 0.4 222 29 185 300 -6 0 -5.9 -6.1 12/05/2005 16:50:00 1.9 0.6 3 0.7 1.9 0.7 3 0.4 1.9 0.5 3 0.7 201 22 176 300 -6 0 -5.9 -6.1 12/05/2005 17:00:00 2.1 0.5 3.4 0.7 2.1 0.5 3.4 1.1 1.9 0.5 3 0.4 224 21 248 300 -6 0 -5.9 -5.9 12/05/2005 17:10:00 2.8 0.7 4.9 0.7 2.8 0.6 4.9 1.1 2.2 0.7 4.2 0.7 231 19 243 300 -5.9 0 -5.7 -5.9 12/05/2005 17:20:00 2.1 0.6 4.2 0.7 2.1 0.6 4.2 0.7 1.9 0.6 3.4 0.4 223 15 239 300 -5.8 0 -5.7 -5.9 12/05/2005 17:30:00 1.7 0.6 3 0.4 1.8 0.6 3 0.4 1.6 0.5 2.6 0.4 213 22 245 300 -5.7 0 -5.5 -5.7 12/05/2005 17:40:00 1.7 0.7 3.4 0.4 1.8 0.7 3.4 0.4 1.7 0.6 3 0.4 224 26 264 300 -5.7 0 -5.7 -5.7 12/05/2005 17:50:00 1.9 0.7 3.4 0.4 1.8 0.7 3.4 0.4 1.6 0.6 3.4 0.4 245 22 229 300 -5.7 0 -5.5 -5.7 12/05/2005 18:00:00 1.5 0.7 2.6 0.4 1.4 0.7 2.6 0.4 1.3 0.6 2.6 0.4 252 39 299 300 -5.6 0 -5.5 -5.7 12/05/2005 18:10:00 1.5 0.7 3 0.4 1.5 0.7 3 0.4 1.4 0.6 2.3 0.4 227 11 263 300 -5.5 0 -5.5 -5.7 12/05/2005 18:20:00 1.1 0.6 2.3 0.4 1.1 0.6 2.3 0.4 1 0.5 2.3 0.4 223 20 248 300 -5.4 0 -5.5 -5.5 12/05/2005 18:30:00 2.3 0.6 3.8 1.1 2.2 0.5 3.8 1.1 2.1 0.5 3 0.7 218 22 237 300 -5.4 0 -5.5 -5.5 12/05/2005 18:40:00 2.3 0.6 4.2 0.7 2.4 0.6 3.8 1.1 2.1 0.5 3.4 0.7 227 12 231 300 -5.4 0 -5.5 -5.5 12/05/2005 18:50:00 1.8 0.7 3 0.4 1.6 0.8 3 0.4 1.4 0.6 2.6 0.4 249 32 245 300 -5.4 0 -5.3 -5.5 12/05/2005 19:00:00 1.5 0.9 3 0.4 1.4 0.9 3.4 0.4 1.2 0.7 2.6 0.4 239 23 249 300 -5.3 0 -5.3 -5.5 12/05/2005 19:10:00 2 0.6 3.4 0.7 2 0.6 3.4 0.4 1.7 0.6 3 0.4 218 14 226 300 -5.3 0 -5 -5.5 12/05/2005 19:20:00 2 0.7 3.8 0.4 2 0.7 3.4 0.4 1.7 0.7 3 0.4 245 19 247 300 -5.1 0 -5 -5.3 12/05/2005 19:30:00 2.3 0.6 3.8 1.1 2.3 0.6 3.8 0.7 2.1 0.5 3.8 1.1 241 22 245 300 -5 0 -4.8 -5 12/05/2005 19:40:00 2.2 0.7 3.8 0.4 2.1 0.8 3.8 0.4 2 0.7 3.4 0.4 241 22 250 300 -4.9 0 -4.8 -5 12/05/2005 19:50:00 2.1 0.5 3 0.7 2 0.5 3 1.1 1.8 0.5 3 0.4 236 22 247 300 -4.9 0 -4.8 -4.8 12/05/2005 20:00:00 1.8 0.5 3 0.4 1.9 0.4 2.6 0.4 1.8 0.4 3 0.7 221 11 223 300 -4.9 0 -4.8 -5.3 12/05/2005 20:10:00 1.6 1.1 4.6 0.4 1.5 1.1 4.2 0.4 1.4 1 4.2 0.4 242 33 259 300 -4.9 0 -4.6 -4.8 12/05/2005 20:20:00 0.8 0.6 2.3 0.4 0.9 0.6 2.3 0.4 0.9 0.5 2.3 0.4 245 26 205 300 -4.8 0 -4.6 -4.8 12/05/2005 20:30:00 0.8 0.4 1.9 0.4 0.7 0.4 1.9 0.4 1.1 0.4 2.3 0.4 254 35 259 300 -4.7 0 -4.6 -4.8 12/05/2005 20:40:00 0.8 0.6 2.3 0.4 0.8 0.6 2.3 0.4 1 0.5 2.3 0.4 215 39 244 300 -4.7 0 -4.6 -4.8 12/05/2005 20:50:00 0.9 0.6 3 0.4 1 0.6 3 0.4 1.1 0.5 2.6 0.4 188 66 39 300 -4.7 0 -4.6 -4.6 12/05/2005 21:00:00 1.5 1 3.8 0.4 1.6 1 3.4 0.4 1.4 1 3.4 0.4 127 64 354 300 -4.6 0 -4.4 -4.6 12/05/2005 21:10:00 1.7 0.8 4.6 0.4 1.8 0.8 3.8 0.4 1.6 0.9 4.9 0.4 80 43 22 300 -4.3 0 -3.9 -4.6 12/05/2005 21:20:00 1.7 1 4.9 0.4 1.8 1 4.9 0.4 1.8 0.8 3.4 0.4 112 49 109 300 -4.2 0.1 -3.9 -4.6 12/05/2005 21:30:00 2.5 1 5.3 0.4 2.5 0.9 4.9 0.4 2.2 0.8 4.2 0.4 129 43 181 300 -4.2 0.1 -3.9 -4.4 12/05/2005 21:40:00 2 1.3 4.6 0.4 2 1.3 4.9 0.4 1.8 1.2 4.2 0.4 133 58 135 300 -4.3 0 -4.2 -4.6 12/05/2005 21:50:00 1.8 1.2 5.7 0.4 1.8 1.3 6.1 0.4 1.5 1 4.9 0.4 124 76 22 300 -4.2 0.1 -3.7 -4.4 12/05/2005 22:00:00 2.8 1 6.5 0.4 2.8 1.1 6.1 0.4 2.3 1 4.9 0.4 87 43 10 300 -3.9 0.1 -3.7 -4.2 12/05/2005 22:10:00 4.8 1.9 9.9 1.1 4.7 1.8 9.5 1.1 4.2 1.3 7.6 1.1 54 29 61 300 -2.6 0.5 -2.1 -3.7 12/05/2005 22:20:00 5 1.9 11.5 0.4 4.9 1.9 11.5 0.4 4.3 1.8 8.8 0.7 45 28 51 300 -2.1 0 -1.9 -2.1 12/05/2005 22:30:00 6.9 1.8 11.8 1.9 6.4 1.7 10.7 1.5 5.3 1.5 9.1 1.9 32 16 19 300 -2 0 -1.9 -2.1 12/05/2005 22:40:00 9.3 1.9 14.5 4.6 8.5 1.8 13.3 3.8 7.2 1.5 12.2 3.4 24 13 43 300 -2 0 -1.9 -2.1 12/05/2005 22:50:00 8.3 1.9 13 2.6 7.6 1.9 13 2.3 6.5 1.6 10.7 2.6 30 16 28 300 -1.7 0 -1.7 -1.9 12/05/2005 23:00:00 8.1 1.8 13 3.8 7.5 1.7 12.2 3.4 6.2 1.7 11.8 2.3 33 17 21 300 -1.7 0 -1.7 -1.9 12/05/2005 23:10:00 8.1 1.9 13.3 3.8 7.6 2 13.3 3 6.1 2 11.5 1.9 36 17 26 300 -1.7 0 -1.7 -1.9 12/05/2005 23:20:00 9.9 1.7 14.1 6.1 9.1 1.6 13 4.6 7.5 1.7 11.5 3.4 28 13 35 300 -1.8 0 -1.7 -1.9 12/05/2005 23:30:00 10 1.7 14.1 4.2 9 1.6 13 3.4 7.7 1.5 11.8 4.2 28 13 34 300 -1.7 0 -1.7 -1.9 12/05/2005 23:40:00 9.4 1.5 13.7 5.7 8.6 1.5 12.2 5.3 7.1 1.4 11.1 3.8 26 13 19 300 -1.7 0 -1.4 -1.9 12/05/2005 23:50:00 10.1 1.9 15.3 4.2 9.1 1.7 13.7 3.4 7.8 1.7 13.3 3.8 25 13 19 300 -1.7 0 -1.4 -1.7 12/06/2005 00:00:00 10 1.8 14.1 4.9 9.3 1.9 14.9 4.2 7.9 1.7 13.7 3.8 24 13 30 300 -1.6 0 -1.4 -1.7 12/06/2005 00:10:00 10 1.8 13.7 4.9 9.3 1.8 13.7 4.6 7.8 1.7 13.7 3.8 21 14 22 300 -1.6 0 -1.4 -1.7 12/06/2005 00:20:00 6.6 1.7 12.2 1.9 6.2 1.7 11.1 2.3 5.1 1.5 9.1 1.5 35 17 23 300 -1.4 0 -1.2 -1.4 12/06/2005 00:30:00 5 1.5 9.1 0.7 4.9 1.5 9.5 1.1 4.3 1.3 8 1.5 55 24 53 300 -1.3 0 -1.2 -1.4 12/06/2005 00:40:00 4.5 1.1 7.6 1.5 4.5 1.1 7.6 1.9 3.7 1 7.6 1.1 65 22 36 300 -1.3 0 -1 -1.4 12/06/2005 00:50:00 4.3 1.5 8.4 0.4 4.3 1.5 8.8 0.4 3.4 1.3 6.5 0.4 50 35 60 300 -1.2 0 -1 -1.2 12/06/2005 01:00:00 2.6 0.9 5.3 0.4 2.8 0.9 5.3 1.1 2.4 0.8 4.9 0.4 94 29 91 300 -1.3 0 -1.2 -1.7 12/06/2005 01:10:00 1.7 1 4.2 0.4 1.8 1 4.2 0.4 1.5 1 3.8 0.4 95 56 103 300 -2.5 0.4 -1.4 -3 12/06/2005 01:20:00 1.5 0.9 3.4 0.4 1.5 1 3.4 0.4 1.3 1 3.4 0.4 108 66 171 300 -3.5 0.2 -2.8 -3.9 12/06/2005 01:30:00 2 0.8 3.8 0.4 2 0.8 3.8 0.4 1.9 0.8 3.4 0.4 100 61 9 300 -3.7 0.1 -3.3 -3.9 12/06/2005 01:40:00 1.7 0.8 4.2 0.4 1.7 0.8 3.8 0.4 1.5 0.5 3 0.4 70 45 40 300 -4 0.1 -3.7 -4.2 12/06/2005 01:50:00 1.3 0.8 3.4 0.4 1.4 0.8 3.4 0.4 1.5 0.7 3 0.4 80 45 23 300 -3.9 0.2 -3.5 -4.4 12/06/2005 02:00:00 2.4 0.9 4.9 0.4 2.5 0.8 4.9 0.4 2.3 0.7 4.2 0.4 83 56 35 300 -4 0 -3.5 -4.2 12/06/2005 02:10:00 2.5 1.7 6.5 0.4 2.6 1.7 6.5 0.4 2.2 1.5 5.3 0.4 75 35 35 300 -3.7 0.3 -2.8 -3.9 12/06/2005 02:20:00 3.1 0.8 5.7 1.1 3.2 0.8 5.7 1.1 2.8 0.9 4.9 0.7 125 32 166 300 -3.7 0.2 -3 -3.9 12/06/2005 02:30:00 2.4 1.1 4.6 0.4 2.4 1.1 4.2 0.4 2.1 1 3.8 0.4 136 66 19 300 -3.9 0 -3.7 -3.9 12/06/2005 02:40:00 2.8 1.3 6.8 0.4 2.7 1.3 7.2 0.4 2.1 1.2 5.3 0.4 106 64 158 300 -3.7 0 -3.5 -3.9 12/06/2005 02:50:00 2.5 1.3 5.3 0.4 2.4 1.3 5.3 0.4 2.4 1.1 4.9 0.4 121 102 146 300 -3.6 0.1 -3.3 -3.7 12/06/2005 03:00:00 2.7 1.3 5.3 0.4 2.6 1.3 5.3 0.4 2.4 1.1 4.9 0.4 101 72 8 300 -3.6 0.1 -3.3 -3.7 12/06/2005 03:10:00 2.6 1.1 5.3 0.4 2.6 1 5.3 0.4 2 1 4.2 0.4 98 58 85 300 -3.5 0 -3.3 -3.5 12/06/2005 03:20:00 2.3 1.2 6.5 0.4 2.4 1.2 6.8 0.4 2.2 1 5.3 0.4 133 82 70 300 -3.4 0.2 -3 -3.5 12/06/2005 03:30:00 1.9 0.8 4.2 0.4 2 0.8 4.2 0.4 1.9 0.7 3.4 0.4 126 47 124 300 -3.7 0 -3.5 -3.7 12/06/2005 03:40:00 3 1.1 6.5 0.4 3.1 1.1 5.7 0.4 2.5 0.9 4.6 0.4 99 56 25 300 -3.3 0.2 -2.8 -3.7 12/06/2005 03:50:00 3.9 2.3 9.5 0.4 3.8 2 9.5 0.4 2.6 1.7 8 0.4 56 53 53 300 -3 0.6 -1.9 -3.5 12/06/2005 04:00:00 7.9 1.4 11.8 3.4 7.2 1.3 10.3 3.8 5.6 1.3 9.1 1.1 33 14 32 300 0.2 0.9 1.1 -2.1 12/06/2005 04:10:00 6.2 1.5 9.9 1.9 5.8 1.3 9.5 2.3 4.8 1.4 9.5 1.5 33 17 47 300 1.1 0 1.4 0.9 12/06/2005 04:20:00 3 2.1 9.1 0.4 3.1 2 9.5 0.4 2.8 1.7 8 0.4 165 79 57 300 -0.4 1.3 1.4 -2.1 12/06/2005 04:30:00 2.1 1.3 6.5 0.4 2.3 1.4 7.2 0.4 1.9 1.2 5.3 0.4 92 61 79 300 -1.4 0.4 -0.7 -2.1 12/06/2005 04:40:00 4.7 1.9 10.7 0.7 4.7 1.7 9.9 1.1 3.8 1.5 7.6 0.7 73 47 32 300 -0.3 0.6 0.7 -1.4 12/06/2005 04:50:00 3.3 1 6.1 0.4 3.4 1 6.1 1.1 2.7 1 5.3 0.4 67 41 22 300 -0.9 0.4 -0.1 -1.4 12/06/2005 05:00:00 3.1 1.2 6.5 0.4 3.2 1.1 6.8 0.4 2.7 1 6.1 0.4 98 64 40 300 -2.4 0.3 -1.2 -2.6 12/06/2005 05:10:00 4.5 1.6 9.5 0.7 4.5 1.5 9.5 1.1 3.7 1.6 9.1 0.4 60 35 32 300 -1.3 0.6 -0.3 -2.1 12/06/2005 05:20:00 4.3 1.7 8.8 0.4 4.3 1.6 8.8 0.4 3.3 1.3 6.8 0.4 41 27 68 300 -0.2 0.5 0.4 -0.7 12/06/2005 05:30:00 2.6 1.4 7.2 0.4 2.8 1.3 6.8 0.4 2.7 1.1 6.5 1.1 122 53 76 300 -1 0.9 0.7 -2.1 12/06/2005 05:40:00 2.2 1.1 4.9 0.4 2.4 1 5.3 0.4 2 1.1 4.9 0.4 120 39 135 300 -1.6 0.3 -1.2 -2.1 12/06/2005 05:50:00 4 1.2 7.6 1.1 4 1.2 8 1.1 3.3 1.2 6.8 0.4 57 33 76 300 -1 0.4 -0.1 -1.9 12/06/2005 06:00:00 2.5 1.3 6.8 0.4 2.6 1.3 6.5 0.4 2.4 1.3 5.7 0.4 127 56 62 300 -1.7 0.9 0.2 -2.8 12/06/2005 06:10:00 2.4 0.9 4.2 0.4 2.5 0.9 4.2 0.4 2.6 0.7 4.6 1.1 207 41 192 300 -2.9 0 -2.6 -2.8 12/06/2005 06:20:00 2.5 1.5 5.7 0.4 2.7 1.8 5.7 0.4 2.8 1.6 5.3 0.4 275 86 218 300 -2.6 0.2 -2.1 -3 12/06/2005 06:30:00 2.3 0.7 4.2 0.4 2.4 0.8 5.3 0.4 2.7 0.9 5.3 0.4 217 28 224 300 -3 0 -2.8 -3.3 12/06/2005 06:40:00 2.4 0.9 4.2 0.4 2.6 0.9 3.8 0.4 2.4 0.6 3.8 1.1 207 20 189 300 -3.1 0 -3 -3.3 12/06/2005 06:50:00 2.8 0.5 3.8 1.1 3 0.5 4.2 1.1 2.7 0.5 4.2 1.1 216 17 216 300 -3.1 0 -3 -3.3 12/06/2005 07:00:00 3.2 0.6 4.6 1.5 3.2 0.6 4.2 1.5 2.9 0.7 4.6 0.7 237 17 259 300 -3.1 0 -3 -3.3 12/06/2005 07:10:00 2.9 0.5 4.2 1.5 2.8 0.6 3.8 1.5 2.5 0.6 3.8 0.7 247 15 238 300 -3.1 0 -3 -3.3 12/06/2005 07:20:00 3.7 0.7 4.9 1.5 3.7 0.6 4.9 1.5 3.3 0.7 4.6 1.5 247 15 248 300 -3 0 -3 -3.3 12/06/2005 07:30:00 4.2 1 6.5 1.9 4.1 1 6.5 1.5 3.7 1 6.1 1.5 246 9 254 300 -3 0 -2.8 -3 12/06/2005 07:40:00 4.8 0.8 6.1 2.3 4.7 0.8 6.1 2.3 4.3 0.9 5.7 1.5 253 6 256 300 -2.9 0 -2.8 -3 12/06/2005 07:50:00 3.9 0.5 5.3 2.3 3.9 0.5 5.3 2.6 3.5 0.6 4.6 1.9 242 13 254 300 -2.8 0 -2.6 -2.8 12/06/2005 08:00:00 2.5 1.1 4.9 0.4 2.4 1.1 4.9 0.4 2.3 1.1 4.6 0.4 233 15 225 300 -2.7 0 -2.6 -2.8 12/06/2005 08:10:00 2.4 1.4 4.9 0.4 2.4 1.3 4.9 0.4 2.4 1.1 4.9 0.4 232 24 239 300 -2.8 0 -2.6 -2.8 12/06/2005 08:20:00 3.3 0.9 5.3 1.1 3.3 0.9 5.3 1.1 3 0.9 4.9 1.1 239 11 246 300 -2.7 0 -2.6 -2.8 12/06/2005 08:30:00 2.6 0.6 4.2 1.1 2.7 0.6 3.8 1.1 2.2 0.6 3.8 0.4 248 15 235 300 -2.6 0 -2.6 -2.8 12/06/2005 08:40:00 2.4 0.5 3.4 0.4 2.3 0.5 3.4 0.4 2 0.8 3.4 0.4 261 9 256 300 -2.6 0 -2.6 -2.6 12/06/2005 08:50:00 2.1 1 5.3 0.4 2.1 0.9 4.9 0.7 1.8 0.6 4.6 0.7 332 43 20 300 -2.5 0 -2.4 -2.6 12/06/2005 09:00:00 2.1 1.2 4.9 0.4 2.1 1.3 4.9 0.4 1.7 1.1 4.6 0.4 78 64 34 300 -2.1 0.2 -1.7 -2.4 12/06/2005 09:10:00 1.6 0.8 4.6 0.4 1.9 1 4.6 0.4 1.7 0.8 4.6 0.4 150 66 208 300 -2.3 0.1 -1.9 -2.6 12/06/2005 09:20:00 3.2 2 6.8 0.4 3.3 2 6.8 0.4 3.1 1.7 6.1 0.4 178 66 237 300 -2.2 0.1 -1.9 -2.6 12/06/2005 09:30:00 3.1 0.8 5.3 1.1 3.1 0.8 5.3 0.7 2.7 0.9 4.6 0.4 265 15 244 300 -2.5 0 -2.4 -2.6 12/06/2005 09:40:00 1.8 0.6 3 0.4 1.8 0.6 3 0.4 1.5 0.6 2.6 0.4 288 17 279 300 -2.5 0 -2.4 -2.6 12/06/2005 09:50:00 1.8 0.8 3.4 0.4 1.9 0.8 3.4 0.4 1.7 0.7 3 0.4 329 12 345 300 -2.2 0 -2.1 -2.6 12/06/2005 10:00:00 0.7 0.5 1.9 0.4 0.8 0.6 2.3 0.4 0.9 0.6 2.3 0.4 334 38 328 300 -1.7 0.1 -1.4 -2.1 12/06/2005 10:10:00 2.1 1.2 5.3 0.4 2.2 1.2 5.3 0.4 2 0.9 4.2 0.4 43 39 29 300 -1.7 0.4 -0.7 -2.1 12/06/2005 10:20:00 1.2 0.7 3.4 0.4 1.5 0.7 3.4 0.4 1.2 0.6 2.6 0.4 47 22 24 300 -0.6 0 -0.5 -1.2 12/06/2005 10:30:00 2.3 1.5 5.7 0.4 2.3 1.3 5.7 0.4 1.7 0.9 4.6 0.4 45 32 27 300 -1.6 0.1 -1 -1.9 12/06/2005 10:40:00 2.7 1.1 5.7 0.4 2.7 1.1 5.7 0.7 2.2 0.9 4.9 0.4 27 18 19 300 -0.1 0.5 0.7 -1.2 12/06/2005 10:50:00 3.3 1.1 6.5 0.4 3.2 1.1 6.1 0.4 2.7 0.9 5.3 0.4 25 18 22 300 0.9 0 1.1 0.7 12/06/2005 11:00:00 3.6 1.3 6.5 0.4 3.5 1.3 6.8 0.7 2.9 1.1 6.1 0.4 33 20 22 300 1 0 1.4 0.9 12/06/2005 11:10:00 6.2 1.5 9.9 2.6 5.8 1.5 9.5 1.9 4.8 1.3 9.1 1.5 26 11 21 300 1 0 1.4 0.9 12/06/2005 11:20:00 5.2 1.3 9.1 2.3 4.9 1.2 8.4 2.3 3.9 1.1 7.6 1.5 30 17 37 300 1.2 0 1.4 1.1 12/06/2005 11:30:00 5.2 1.3 8.4 1.5 5.1 1.3 8.4 1.5 4.1 1.2 7.6 1.5 23 16 16 300 1.4 0 1.6 1.4 12/06/2005 11:40:00 3.9 1.5 8 0.4 3.8 1.3 8 1.1 3.1 1.4 6.5 0.4 41 29 35 300 1.3 0 1.6 1.4 12/06/2005 11:50:00 2.9 1.5 6.5 0.4 3.1 1.5 6.8 0.4 2.9 1.2 7.2 0.4 61 38 82 300 1.2 0 1.4 0.9 12/06/2005 12:00:00 3.5 1.7 8 0.4 3.6 1.6 8 0.4 3.2 1.5 8 0.4 50 33 43 300 1 0 1.1 0.9 12/06/2005 12:10:00 5.9 1.6 9.5 2.3 5.4 1.5 9.1 2.6 4.3 1.2 7.6 1.1 25 20 21 300 1.2 0.1 1.4 0.9 12/06/2005 12:20:00 7.3 1.4 10.3 3.4 6.9 1.3 10.3 3.8 5.8 1.3 9.1 1.9 24 15 29 300 1.5 0 1.8 1.4 12/06/2005 12:30:00 7.2 1.3 10.3 3.8 6.8 1.4 10.3 3.8 5.6 1.4 10.3 2.3 19 13 22 300 1.7 0 1.8 1.6 12/06/2005 12:40:00 6.4 1.1 9.1 3.4 6.1 1.1 9.5 3.4 5 1.2 8.4 1.9 24 14 26 300 1.7 0 1.8 1.6 12/06/2005 12:50:00 5.1 1.2 8 1.5 5 1.3 9.1 1.9 4 1 7.2 1.9 17 14 10 300 1.8 0 2.1 1.8 12/06/2005 13:00:00 5.8 1.1 8.4 2.6 5.7 1.1 8.8 2.6 4.5 1 7.6 1.9 13 13 13 300 2.1 0.3 2.8 1.8 12/06/2005 13:10:00 4.6 1 8 2.3 4.6 1 8.4 2.3 3.9 1 6.8 1.9 9 14 25 300 2.9 0 3.3 2.6 12/06/2005 13:20:00 6.2 1.7 10.7 2.6 6 1.6 10.3 2.3 5 1.3 9.5 0.7 21 21 27 300 3.5 0.4 4.3 3 12/06/2005 13:30:00 6.4 1.5 10.7 2.6 6.1 1.5 9.9 2.6 4.9 1.4 9.1 1.5 37 17 38 300 4.3 0 4.5 4.3 12/06/2005 13:40:00 5.8 1.2 9.1 2.6 5.4 1.2 8.8 1.9 4.1 1.1 8.8 1.1 25 15 35 300 4.2 0.2 4.5 3.8 12/06/2005 13:50:00 5.8 1 8.4 3.4 5.7 1 8.4 3 4.3 1 6.8 1.9 35 10 33 300 3.9 0 4 3.8 12/06/2005 14:00:00 5.1 1 7.2 1.9 5.1 1.1 7.2 2.3 4.1 1.3 6.8 1.5 7 13 45 300 3.8 0 4 3.5 12/06/2005 14:10:00 6.8 1.1 9.5 4.2 6.9 1.1 9.5 4.6 6 1.2 9.1 3 353 12 19 300 3 0.4 4 2.6 12/06/2005 14:20:00 6.1 1.1 8.8 2.6 6.2 1.2 9.1 3 5.4 1.2 8.4 2.6 356 10 3 300 2.7 0.1 2.8 2.3 12/06/2005 14:30:00 5.8 0.8 8 3.4 5.8 0.8 8 3.4 5.1 1 8 2.3 358 11 4 300 3.2 0.2 3.5 2.8 12/06/2005 14:40:00 5.4 1.3 8.8 1.9 5.2 1.2 9.1 2.3 4.2 1.2 8.4 1.9 45 23 71 300 4.1 0.3 4.5 3.5 12/06/2005 14:50:00 4.2 1.3 9.9 1.5 4.3 1.3 10.3 1.5 3.5 1.4 9.1 0.4 52 23 82 300 4.6 0 4.8 4.5 12/06/2005 15:00:00 1.8 1.1 5.7 0.4 2.1 1 6.1 0.4 2.1 0.9 6.1 0.4 182 47 147 300 1.9 1 4.5 0.9 12/06/2005 15:10:00 2 0.8 4.6 0.4 2.1 0.9 4.9 0.4 2 0.8 3.8 0.4 188 51 233 300 0.3 0.2 0.9 -0.1 12/06/2005 15:20:00 1.2 0.6 3 0.4 1.1 0.6 3 0.4 1.1 0.6 2.6 0.4 79 61 10 300 -0.2 0 -0.1 -0.3 12/06/2005 15:30:00 1.9 1 4.2 0.4 2 1 4.2 0.4 1.8 1 3.8 0.4 120 86 43 300 -0.3 0 -0.1 -0.3 12/06/2005 15:40:00 1.9 1 4.9 0.4 1.9 1 4.6 0.4 1.9 0.7 3.8 0.4 50 32 20 300 0.1 0 0.2 -0.3 12/06/2005 15:50:00 2 1 4.6 0.4 2.1 1 4.2 0.4 1.9 0.8 3.4 0.4 73 41 23 300 -0.2 0.1 0.2 -0.5 12/06/2005 16:00:00 3.6 1.7 8.4 0.4 3.6 1.6 7.6 0.4 2.9 1.3 7.2 0.4 105 69 122 300 0.2 0.4 0.9 -0.3 12/06/2005 16:10:00 1.5 0.9 3.4 0.4 1.5 0.9 3 0.4 1.6 0.8 3 0.4 89 90 24 300 -0.4 0 -0.1 -0.5 12/06/2005 16:20:00 1.9 1.2 4.2 0.4 2.1 1.2 4.6 0.4 2 0.9 4.2 0.4 190 23 178 300 -0.5 0 -0.5 -0.7 12/06/2005 16:30:00 1.7 1 3.8 0.4 1.8 1 4.2 0.4 1.6 1 4.2 0.4 200 35 227 300 -0.6 0 -0.5 -0.7 12/06/2005 16:40:00 2.7 0.8 4.9 1.5 2.7 0.8 4.6 1.1 2.5 0.8 4.9 1.1 259 41 243 300 -0.4 0 -0.3 -0.5 12/06/2005 16:50:00 1.8 0.6 3 0.4 1.7 0.7 3 0.4 2.1 0.7 3.4 0.4 324 64 320 300 -0.1 0.2 0.2 -0.3 12/06/2005 17:00:00 1.5 0.9 3 0.4 1.6 0.9 3.4 0.4 1.6 1 3 0.4 128 86 197 300 -0.1 0.1 0.2 -0.3 12/06/2005 17:10:00 1.4 1 3 0.4 1.5 1 3.4 0.4 1.6 1 3.4 0.4 149 66 182 300 -0.4 0 -0.3 -0.5 12/06/2005 17:20:00 0.4 0.2 1.1 0.4 0.5 0.3 1.5 0.4 0.5 0.3 1.5 0.4 119 51 42 300 -0.5 0 -0.5 -0.5 12/06/2005 17:30:00 0.9 0.8 3 0.4 1 0.8 3.4 0.4 0.7 0.4 1.9 0.4 81 26 69 300 -0.4 0 -0.3 -0.5 12/06/2005 17:40:00 2.7 1.1 6.1 0.4 2.8 1.1 5.7 0.4 2.1 0.9 4.2 0.4 65 26 66 300 0 0.2 0.2 -0.5 12/06/2005 17:50:00 3.1 1.7 6.5 0.4 3.1 1.7 6.5 0.4 2.8 1.1 5.7 0.4 107 72 47 300 0.8 0.4 1.4 0.2 12/06/2005 18:00:00 1.3 1.2 5.3 0.4 1.4 1.2 5.3 0.4 1.5 0.8 3.8 0.4 325 72 67 300 0.8 0.5 1.8 0.2 12/06/2005 18:10:00 1.9 0.9 4.9 0.4 2 0.8 4.6 0.4 1.6 0.6 3 0.4 70 61 127 300 1.4 0 1.8 1.4 12/06/2005 18:20:00 0.7 0.5 2.6 0.4 0.8 0.6 2.6 0.4 0.9 0.5 2.3 0.4 147 72 110 300 1.3 0 1.6 1.1 12/06/2005 18:30:00 3.5 2 7.6 0.4 3.6 2 8.4 0.4 2.7 1.8 6.8 0.4 76 47 80 300 2.7 1 4.3 1.6 12/06/2005 18:40:00 7.1 1.8 14.1 3 7.2 1.8 13.7 3 6 1.9 12.6 2.3 69 18 87 300 5.4 0.6 6.2 4.5 12/06/2005 18:50:00 6.1 1.3 11.1 3 6.1 1.3 11.5 3.4 4.9 1.3 8.8 1.9 51 15 59 300 5.7 0.4 6.2 5 12/06/2005 19:00:00 6.2 1.2 9.5 3 6.1 1.2 9.1 2.6 4.3 1.1 7.6 1.9 44 16 35 300 4.3 0.3 5 3.8 12/06/2005 19:10:00 6.5 1.4 9.5 1.1 6.1 1.4 9.9 1.9 4.5 1.5 8.4 1.1 23 17 21 300 3.1 0.4 4 2.6 12/06/2005 19:20:00 7.2 1.2 9.9 2.3 6.6 1.2 9.5 2.3 5 1.2 9.1 1.1 21 12 18 300 2.6 0 2.8 2.6 12/06/2005 19:30:00 6.9 1.3 9.9 2.6 6.3 1.2 9.9 2.6 4.8 1.2 8 1.5 27 14 33 300 3.1 0.2 3.5 2.6 12/06/2005 19:40:00 6.2 1.3 10.3 2.3 5.7 1.3 10.7 2.3 4.2 1.2 8.4 1.1 27 15 55 300 3.8 0 4 3.5 12/06/2005 19:50:00 5.3 1 7.6 1.1 5.1 1 7.6 1.9 4.1 1.2 6.8 0.4 33 17 31 300 3.6 0.1 3.8 3.5 12/06/2005 20:00:00 6 1.1 8.4 3.4 5.5 1.1 8 3 4 1.1 6.5 1.5 28 13 37 300 3.2 0 3.5 3.3 12/06/2005 20:10:00 5.8 1 9.1 2.6 5.3 1.1 8 2.6 4 1 6.8 1.5 20 12 20 300 3.2 0.1 3.5 2.8 12/06/2005 20:20:00 4.7 1.1 7.2 2.3 4.4 1.1 6.8 1.9 3.3 1.1 5.7 0.4 18 16 18 300 2.9 0 3 2.8 12/06/2005 20:30:00 4.4 1 6.5 1.9 4 1 6.1 1.5 2.9 0.8 4.9 0.7 27 15 26 300 2.9 0 2.8 2.8 12/06/2005 20:40:00 3.7 1.2 6.1 0.4 3.7 1 6.5 1.1 2.6 1.2 6.5 0.4 36 16 48 300 3 0 3.3 2.8 12/06/2005 20:50:00 0.9 0.5 2.3 0.4 1.2 0.5 2.3 0.4 1.2 0.5 3 0.4 107 58 52 300 2.9 0 3.3 2.6 12/06/2005 21:00:00 0.4 0.2 1.5 0.4 0.6 0.4 2.6 0.4 0.5 0.3 1.5 0.4 160 43 211 300 2.3 0 2.8 2.1 12/06/2005 21:10:00 0.9 0.6 2.3 0.4 1.1 0.5 2.3 0.4 1.4 0.5 2.6 0.4 200 19 213 300 1.7 0.3 2.3 0.9 12/06/2005 21:20:00 0.8 0.5 2.3 0.4 0.9 0.5 2.3 0.4 1 0.4 1.9 0.4 272 29 297 300 0.7 0 1.1 0.4 12/06/2005 21:30:00 1.3 0.6 2.6 0.4 1.5 0.5 2.6 0.4 1.4 0.4 2.3 0.7 334 15 334 300 0.7 0 0.9 0.7 12/06/2005 21:40:00 2.8 0.5 4.2 1.9 2.9 0.5 4.6 2.3 2.6 0.5 3.8 1.1 343 9 345 300 0.6 0 0.9 0.2 12/06/2005 21:50:00 3 0.6 4.6 1.5 3.1 0.6 4.6 1.5 2.3 0.7 3.8 0.7 4 16 359 300 0.7 0 0.9 0.7 12/06/2005 22:00:00 2.3 0.8 4.2 0.4 2.4 0.8 4.2 0.4 1.6 0.8 3 0.4 10 19 359 300 0.7 0 0.9 0.7 12/06/2005 22:10:00 2.6 1.2 4.9 0.4 2.6 1.1 5.3 0.4 2 0.7 3.8 0.4 20 45 0 300 0.6 0.1 0.9 0.2 12/06/2005 22:20:00 1.7 0.8 3.4 0.4 2 0.7 3.4 0.4 1.9 0.7 3.4 0.4 82 28 94 300 -0.3 0.1 0.2 -0.5 12/06/2005 22:30:00 2.3 0.4 3 1.1 2.4 0.3 3 1.1 2 0.4 3 0.7 42 9 39 300 -0.3 0.1 -0.1 -0.5 12/06/2005 22:40:00 2.8 0.5 4.2 1.5 2.7 0.5 4.6 1.1 2 0.4 3 1.1 29 12 13 300 -0.4 0 -0.1 -0.5 12/06/2005 22:50:00 3 0.7 5.3 1.1 2.8 0.7 5.3 1.1 2 0.5 3.4 1.1 21 12 24 300 -0.1 0 0.2 -0.3 12/06/2005 23:00:00 3.7 0.8 5.7 1.5 3.7 0.8 5.7 1.5 2.7 0.7 4.6 1.1 13 14 0 300 0.2 0 0.2 0.2 12/06/2005 23:10:00 4.2 0.7 6.1 2.3 4.2 0.8 6.1 2.3 3.2 0.8 5.3 1.1 12 10 12 300 0.4 0 0.7 0.2 12/06/2005 23:20:00 4.3 0.7 6.1 2.3 4.3 0.7 6.1 2.6 3.2 0.8 5.7 1.5 8 9 16 300 0.7 0 0.9 0.4 12/06/2005 23:30:00 3.8 0.8 5.7 1.5 3.8 0.9 6.1 1.5 2.8 0.9 4.9 1.1 8 10 12 300 0.8 0 0.9 0.7 12/06/2005 23:40:00 3.5 0.9 5.3 1.1 3.5 0.9 5.7 1.5 2.6 0.8 4.6 0.4 11 12 6 300 0.9 0 1.4 0.9 12/06/2005 23:50:00 3.1 0.6 4.6 1.5 3.1 0.6 4.9 1.5 2.1 0.6 3.8 0.7 14 12 21 300 1.1 0 1.4 0.9 12/07/2005 00:00:00 4 0.8 5.7 2.3 4.1 0.8 6.1 2.3 2.8 0.8 5.3 1.1 8 8 356 300 1.2 0 1.4 1.1 12/07/2005 00:10:00 3 0.9 5.3 1.1 3 1 5.7 1.1 2.3 0.7 4.6 0.7 10 13 2 300 1.4 0 1.6 1.4 12/07/2005 00:20:00 3.4 0.8 6.1 1.5 3.3 0.8 6.1 1.5 2.4 0.8 4.9 0.7 18 11 28 300 1.6 0 1.8 1.6 12/07/2005 00:30:00 4.2 0.8 6.5 1.9 4 0.8 6.1 1.9 3.1 0.7 4.9 1.1 20 11 9 300 1.7 0 1.8 1.6 12/07/2005 00:40:00 3.7 1 6.1 0.4 3.6 1 6.1 0.4 2.8 0.9 4.9 0.7 17 13 39 300 1.8 0 1.8 1.8 12/07/2005 00:50:00 4.4 0.9 6.5 2.3 4.3 1 6.5 2.3 3.1 1 6.8 1.1 11 13 359 300 1.8 0 2.1 1.8 12/07/2005 01:00:00 3.3 1.2 5.7 0.4 3.3 1.2 5.7 0.4 2.4 1 5.7 0.4 9 17 14 300 1.9 0 2.1 1.8 12/07/2005 01:10:00 3.9 1.3 6.5 0.4 3.7 1.1 6.1 0.7 2.6 1.1 5.7 0.4 23 22 19 300 1.8 0 1.8 1.8 12/07/2005 01:20:00 4.4 1.2 7.2 0.4 4.1 1.2 6.8 0.4 2.4 1.1 5.3 0.4 24 30 37 300 1.8 0 1.8 1.8 12/07/2005 01:30:00 4.7 1.3 7.2 0.7 4.3 1.1 7.2 1.5 2.9 1.2 6.5 0.4 30 22 24 300 2 0 2.3 1.8 12/07/2005 01:40:00 5 1.2 8 1.5 4.6 1.1 8 2.3 3 1.1 6.1 0.4 30 17 22 300 2.4 0 2.6 2.3 12/07/2005 01:50:00 5.6 0.9 8 2.6 5.4 1 8 1.9 3.8 0.9 7.2 1.5 38 11 53 300 2.4 0 2.6 2.3 12/07/2005 02:00:00 6 1.2 8.8 2.6 5.7 1.3 8.8 2.3 4.1 1.3 8 0.7 38 13 45 300 2.7 0 2.8 2.6 12/07/2005 02:10:00 5.9 1.2 9.1 2.6 5.7 1.2 9.1 2.6 4 1.2 7.2 1.5 39 13 64 300 3.2 0 3.5 2.8 12/07/2005 02:20:00 6.1 1.2 8.8 3 5.8 1.2 8.8 2.6 4 1.3 8 1.5 38 15 54 300 3.2 0 3.5 3 12/07/2005 02:30:00 5.4 1.1 8 2.3 5 1.1 8 2.6 3.4 1.3 6.8 0.4 32 15 36 300 3.2 0 3.5 3.3 12/07/2005 02:40:00 5.7 1.4 9.1 1.9 5.5 1.4 9.1 1.5 3.9 1.3 7.6 1.5 41 15 41 300 3.1 0 3.5 2.8 12/07/2005 02:50:00 5.7 1.2 9.1 2.3 5.6 1.2 9.5 2.6 4 1 7.6 1.9 41 17 50 300 3.4 0 3.8 3.3 12/07/2005 03:00:00 6.3 1 8.8 2.6 6.1 1.1 8.4 2.6 4.6 1.1 7.6 1.9 38 15 28 300 3.4 0.2 3.8 2.8 12/07/2005 03:10:00 6 1.2 10.3 2.3 5.5 1.1 10.3 2.6 4.3 1.2 8.8 1.5 36 18 18 300 2.9 0 3 2.8 12/07/2005 03:20:00 5.2 1.4 8.4 1.5 4.8 1.3 8 0.7 3.7 1.1 6.5 0.7 29 39 26 300 2.9 0.2 3.5 2.6 12/07/2005 03:30:00 5.7 0.9 8.4 3.8 5.3 1 8 2.6 3.8 1 7.2 1.1 33 12 23 300 3.4 0 3.5 3.3 12/07/2005 03:40:00 5.6 1.5 12.2 2.3 5.6 1.5 12.2 1.9 4.3 1.4 10.3 1.5 44 15 51 300 3.5 0 3.8 3.3 12/07/2005 03:50:00 6.1 1.8 11.8 2.6 6.1 1.9 12.2 2.6 4.6 2 10.7 1.1 47 19 82 300 3.5 0.2 4.5 3.5 12/07/2005 04:00:00 5.5 1.2 10.3 2.6 5.6 1.3 10.7 2.3 4 1.3 7.6 0.7 55 18 74 300 4.7 0 4.8 4.5 12/07/2005 04:10:00 5 1 7.2 1.9 5 1.1 8 1.9 3.7 1.1 6.5 1.1 48 15 58 300 4.6 0.1 4.8 4.5 12/07/2005 04:20:00 6.2 1.2 9.9 1.9 6.2 1.2 9.9 2.6 4.6 1.2 8.4 1.9 53 18 54 300 4.9 0.5 5.7 4.3 12/07/2005 04:30:00 6.3 1.5 10.7 3.4 6.4 1.5 10.3 3 4.8 1.5 9.1 0.7 63 18 77 300 5.8 0.2 6.2 5.5 12/07/2005 04:40:00 7.1 2.3 15.3 3 7.1 2.4 15.6 3.4 5.7 2.3 13.7 0.7 60 22 57 300 6.8 0.6 7.5 5.7 12/07/2005 04:50:00 6.6 1.7 11.8 3 6.7 1.7 12.6 3 5.5 1.4 10.3 2.3 58 13 69 300 6.9 0 7 6.7 12/07/2005 05:00:00 6.3 1.4 9.9 3 6.2 1.4 9.9 3 4.7 1.5 8.4 1.1 52 18 56 300 6.9 0.1 7.3 6.5 12/07/2005 05:10:00 5.9 1.3 9.1 2.6 5.8 1.5 10.3 2.3 4.4 1.4 8.4 0.7 47 17 65 300 6.1 0 6.5 6 12/07/2005 05:20:00 6.6 1.3 10.7 3 6.4 1.4 11.1 2.3 4.9 1.5 10.7 1.9 46 16 62 300 5.9 0.2 6.2 5.5 12/07/2005 05:30:00 7.5 1.5 11.1 3.8 7.3 1.5 10.7 3.8 5.5 1.6 10.3 1.9 45 13 47 300 6.6 0.1 7 6.2 12/07/2005 05:40:00 7.4 1.5 12.2 2.3 7.2 1.6 12.2 2.3 5.6 1.5 9.9 2.3 42 14 48 300 6.7 0.1 7 6.5 12/07/2005 05:50:00 8.5 1.6 13 3.8 8.4 1.7 12.6 3 6.4 1.9 11.8 1.9 44 11 54 300 6.8 0.1 7.3 6.5 12/07/2005 06:00:00 7.6 1.5 11.8 3.8 7.4 1.7 11.8 3.4 5.8 1.8 11.5 1.9 44 15 37 300 7.4 0.1 7.8 7 12/07/2005 06:10:00 8.9 1.9 15.3 3.8 8.6 2.1 14.5 3.4 6.5 1.7 11.8 0.7 42 16 47 300 7.6 0.2 8 7.3 12/07/2005 06:20:00 7.9 2.4 16.1 2.6 7.7 2.5 16.1 2.6 5.9 2.4 14.9 1.1 44 17 57 300 7.8 0 8 7.8 12/07/2005 06:30:00 8.9 2.3 14.5 3.4 8.7 2.4 14.5 2.6 6.7 2.2 13 0.7 43 16 36 300 8.1 0 8.3 7.8 12/07/2005 06:40:00 7.5 1.5 10.7 3 7.4 1.7 10.7 2.6 5.7 1.7 9.9 1.9 48 14 34 300 7.7 0 7.8 7.5 12/07/2005 06:50:00 6.9 1 9.1 3.4 6.9 1 9.5 3.8 5 1.2 8.8 1.5 49 12 58 300 7.3 0 7.5 7.3 12/07/2005 07:00:00 8.1 2.1 14.5 3.4 8 2.2 14.9 2.6 6.1 2.4 12.6 1.1 56 19 85 300 7.5 0.3 8.3 7.3 12/07/2005 07:10:00 7.2 1.6 11.8 2.6 7.2 1.6 11.8 2.6 5.8 1.5 11.5 2.6 61 19 73 300 8.1 0.1 8.5 7.8 12/07/2005 07:20:00 9.9 2.3 15.3 4.2 10 2.4 16.1 4.6 8.5 2.4 15.6 3 72 16 71 300 8.9 0.1 9.3 8.5 12/07/2005 07:30:00 10.4 2 16.4 4.9 10.5 2 16.4 4.9 8.6 2.2 14.1 2.6 72 15 96 300 9 0 9.3 8.8 12/07/2005 07:40:00 8.4 1.7 13 1.9 8.5 1.9 12.6 1.9 6.5 2.1 11.8 2.6 58 16 87 300 8.7 0.2 9 8.3 12/07/2005 07:50:00 8.2 1.6 13 3.8 8 1.7 13 3 6 1.7 10.7 1.9 45 12 48 300 8.3 0 8.5 8.3 12/07/2005 08:00:00 9.5 1.7 13.7 3.8 9.4 1.7 13.7 3.4 6.9 1.9 12.6 1.9 47 14 57 300 8.2 0.1 8.5 8 12/07/2005 08:10:00 8.1 1.5 12.6 4.6 7.8 1.6 13.7 3.8 5.8 1.5 10.3 1.9 42 15 48 300 8.3 0 8.5 8.3 12/07/2005 08:20:00 7.7 1.8 13.3 2.6 7.7 2 13.3 2.3 6.4 2 11.8 1.5 56 18 71 300 8.5 0 8.8 8.5 12/07/2005 08:30:00 10.4 2.8 19.5 3.8 10.4 2.9 20.2 3.4 8.5 2.5 15.3 4.2 65 15 80 300 8.9 0.1 9.3 8.8 12/07/2005 08:40:00 11.6 2.9 18.3 5.3 11.7 3.1 19.1 4.6 10 3.1 17.9 3.8 70 15 64 300 9.2 0 9.3 9 12/07/2005 08:50:00 9.9 2.5 16.8 4.6 9.9 2.5 16.8 4.6 8.5 2.6 15.3 3.4 70 17 65 300 8.9 0 9 8.8 12/07/2005 09:00:00 9.4 2.3 15.6 4.2 9.6 2.3 16.1 3.8 8.5 2.3 15.6 3.4 69 15 64 300 9 0 9.3 9 12/07/2005 09:10:00 10.9 2.1 16.4 6.1 11 2.1 16.4 5.7 9.2 2 14.9 4.2 73 14 73 300 9.4 0.1 9.8 9 12/07/2005 09:20:00 9.7 2.2 15.6 3 9.8 2.3 16.4 3 7.9 2.4 14.9 2.3 61 17 85 300 9.8 0.1 10.1 9.6 12/07/2005 09:30:00 9.1 2.4 17.6 3.4 9.1 2.4 17.2 3.8 7.5 2.3 13 2.6 66 17 72 300 9.4 0 9.6 9.3 12/07/2005 09:40:00 12.1 2.8 19.1 5.3 12.3 2.7 19.1 5.7 10.8 2.6 17.9 4.9 74 15 70 300 9.6 0 9.8 9.6 12/07/2005 09:50:00 13 2.5 20.2 7.6 13.2 2.5 20.6 7.6 11.6 2.5 17.6 5.7 78 14 82 300 9.5 0 9.6 9.3 12/07/2005 10:00:00 11.5 2.8 18.7 4.9 11.6 2.8 19.1 4.6 10.2 2.6 16.8 4.2 76 17 82 300 9.4 0 9.6 9.3 12/07/2005 10:10:00 12.1 2.5 17.9 6.5 12.3 2.5 18.3 6.8 10.5 2.3 16.8 6.1 74 14 73 300 9.5 0 9.6 9.3 12/07/2005 10:20:00 12.2 2.7 18.3 5.7 12.4 2.8 18.7 6.1 10.5 2.7 18.7 5.7 72 15 69 300 9.6 0 9.8 9.6 12/07/2005 10:30:00 11.7 2.6 19.1 4.6 11.8 2.6 19.5 4.6 10.2 2.6 17.9 4.2 71 14 86 300 9.7 0 9.8 9.6 12/07/2005 10:40:00 11.3 2.7 19.1 4.2 11.5 2.7 19.1 5.3 9.9 2.8 19.5 3.4 72 16 65 300 9.6 0 9.8 9.6 12/07/2005 10:50:00 10.8 2.7 17.9 4.6 11 2.8 18.3 4.9 9.5 2.5 15.6 4.6 70 15 84 300 9.4 0 9.6 9.3 12/07/2005 11:00:00 12.8 3.5 22.1 4.2 13 3.5 22.6 5.3 11.4 3.3 20.6 4.9 75 14 71 300 9.6 0 9.8 9.3 12/07/2005 11:10:00 12.3 2.8 19.9 4.9 12.4 2.8 19.9 3.8 10.7 2.8 18.7 4.6 70 13 76 300 9.8 0 10.1 9.6 12/07/2005 11:20:00 12 2.7 18.3 4.6 12.1 2.8 19.5 4.2 10.5 3.1 19.9 3.8 72 14 84 300 9.7 0 9.8 9.6 12/07/2005 11:30:00 11.8 2.6 18.3 5.3 11.9 2.7 17.9 4.2 10.1 2.3 16.4 4.9 71 16 87 300 9.5 0 9.6 9.3 12/07/2005 11:40:00 12.8 2.9 20.2 5.7 12.9 2.9 20.2 5.3 10.9 2.9 17.6 4.9 68 15 77 300 9.3 0 9.6 9 12/07/2005 11:50:00 13 2.7 20.2 5.7 13.2 2.7 20.2 5.3 11.2 2.8 17.6 4.6 72 13 62 300 9 0 9.3 9 12/07/2005 12:00:00 12.3 2.8 19.1 5.7 12.4 2.9 19.1 4.6 10.6 2.7 17.6 4.6 70 14 87 300 9.2 0 9.3 9 12/07/2005 12:10:00 12.3 2.6 19.1 4.2 12.4 2.7 19.9 4.6 10.8 2.8 18.3 4.2 69 14 64 300 9.1 0 9.3 9 12/07/2005 12:20:00 11.6 2.8 19.9 4.6 11.7 2.9 21 4.9 9.9 2.7 18.3 4.2 68 17 67 300 9 0 9 9 12/07/2005 12:30:00 11.4 2.9 18.7 4.9 11.5 2.9 19.5 4.2 9.9 2.7 17.2 3.8 67 16 76 300 8.9 0 9 8.8 12/07/2005 12:40:00 12.3 2.7 19.9 6.1 12.5 2.8 20.6 5.7 10.8 2.7 18.7 4.6 68 17 63 300 9.1 0 9.3 9 12/07/2005 12:50:00 12.8 3.2 22.6 6.1 13 3.3 22.9 6.1 11.3 2.9 19.5 5.7 72 15 77 300 9.2 0 9.6 9 12/07/2005 13:00:00 12.9 2.9 18.7 5.3 13 3.1 19.9 4.9 11.5 2.8 18.3 5.3 69 17 82 300 9 0.1 9.3 8.8 12/07/2005 13:10:00 12.9 2.7 18.7 5.3 13 2.8 19.1 5.3 11.3 2.8 19.1 4.9 73 16 91 300 8.6 0 8.8 8.5 12/07/2005 13:20:00 13.8 2.9 21 6.8 13.9 3.1 21 4.9 11.8 2.8 20.2 4.2 69 15 59 300 8.5 0 8.8 8.5 12/07/2005 13:30:00 13.2 2.7 22.6 5.7 13.3 2.8 21.4 6.1 11.2 2.8 19.1 4.9 70 15 61 300 8.4 0 8.5 8.5 12/07/2005 13:40:00 12.1 2.9 21.8 4.9 12.3 3.1 22.1 4.2 10.5 2.8 19.9 4.2 68 15 54 300 8.3 0 8.5 8.3 12/07/2005 13:50:00 13.1 2.8 19.9 6.1 13.2 2.9 20.2 6.1 11.2 2.9 18.7 3.8 71 13 72 300 8.4 0 8.5 8.3 12/07/2005 14:00:00 12.8 2.7 20.6 5.3 12.9 2.7 20.6 6.5 11 2.7 20.2 4.9 72 14 63 300 8.3 0 8.5 8 12/07/2005 14:10:00 11.5 2.8 19.5 5.7 11.7 2.7 19.9 6.1 9.9 2.7 17.9 4.2 69 14 81 300 8.1 0 8.3 8 12/07/2005 14:20:00 12.7 2.7 20.2 6.5 12.8 2.7 20.6 6.5 10.7 2.7 18.7 5.3 70 15 61 300 8.1 0 8.3 7.8 12/07/2005 14:30:00 15.1 2.6 21.4 7.6 15.2 2.7 21 6.8 13 2.8 19.1 5.3 71 12 69 300 8 0 8.3 7.8 12/07/2005 14:40:00 15.3 2.9 21.4 6.1 15.5 2.9 21.8 6.5 13.6 3.1 20.2 6.1 74 13 72 300 8.1 0 8.3 8 12/07/2005 14:50:00 14.9 3.1 21.8 7.2 15 3.1 21.8 6.8 13.2 2.9 21 5.7 74 13 57 300 8.1 0 8.5 8 12/07/2005 15:00:00 14.7 3.1 21.8 4.6 14.9 3.1 21.8 5.3 12.5 2.7 19.9 6.8 73 12 60 300 8.2 0 8.5 8 12/07/2005 15:10:00 14.9 2.7 21.8 6.8 14.9 2.8 22.1 5.7 12.7 2.8 19.5 6.1 73 14 77 300 8.1 0 8.5 8 12/07/2005 15:20:00 13.9 3.3 23.3 5.7 14.1 3.5 24 6.1 12.4 2.9 21.8 6.5 76 15 77 300 8.1 0 8.3 8 12/07/2005 15:30:00 13 3.6 22.1 4.9 13.1 3.6 22.1 4.9 11.6 3.1 21.4 4.2 72 16 72 300 8 0 8.3 7.8 12/07/2005 15:40:00 13.2 2.3 19.1 6.8 13.2 2.3 19.9 7.6 11.2 2.4 17.6 5.7 73 13 66 300 8 0 8.3 7.8 12/07/2005 15:50:00 10.8 2.6 17.6 4.9 10.9 2.7 17.6 5.3 9.5 2.5 17.6 3 72 17 84 300 8 0 8.3 7.8 12/07/2005 16:00:00 12.1 2.5 18.3 4.9 12.3 2.6 19.1 5.3 10.6 2.6 18.7 4.9 74 14 83 300 8.2 0 8.5 8 12/07/2005 16:10:00 12.9 2.5 19.5 6.5 13 2.5 19.9 6.8 10.9 2.5 18.3 3.4 73 15 63 300 8.3 0 8.5 8.3 12/07/2005 16:20:00 13.1 2.5 19.9 6.1 13.2 2.6 20.2 4.6 11.3 2.4 17.2 5.3 74 15 83 300 8.3 0 8.5 8.3 12/07/2005 16:30:00 13.9 2.4 20.2 8.4 13.9 2.5 20.2 7.2 12 2.3 17.6 5.3 80 15 76 300 8 0.1 8.3 7.8 12/07/2005 16:40:00 14.3 2.9 22.6 8 14.4 3.1 23.3 7.6 12.7 2.8 21.8 6.1 82 14 82 300 7.7 0 7.8 7.5 12/07/2005 16:50:00 12.6 2.4 19.9 6.8 12.8 2.4 19.9 7.6 10.8 2.4 19.9 4.9 75 14 59 300 7.5 0.1 7.8 7.3 12/07/2005 17:00:00 13.1 2.6 22.1 6.5 13.2 2.6 22.9 7.2 11.4 2.4 19.5 5.7 77 15 77 300 7.3 0 7.5 7.3 12/07/2005 17:10:00 14 3.3 22.1 5.3 14.1 3.3 22.6 4.9 12.4 3.1 22.9 3 78 15 79 300 7.3 0 7.5 7.3 12/07/2005 17:20:00 13.8 2.9 21 6.1 14 2.9 21.4 6.8 11.7 2.8 20.6 5.7 75 15 59 300 7.3 0 7.5 7.3 12/07/2005 17:30:00 15 2.6 21 7.2 15.1 2.7 21 6.8 13.1 2.9 20.2 4.9 79 14 73 300 7.5 0 7.8 7.3 12/07/2005 17:40:00 15.2 2.9 23.7 8 15.3 2.9 24 8.8 13.4 3.1 23.7 6.5 81 15 86 300 7.6 0 7.8 7.5 12/07/2005 17:50:00 16 3.2 24 9.1 16.1 3.2 24.4 8.4 14.8 3.2 24.4 7.6 84 12 76 300 7.8 0 7.8 7.5 12/07/2005 18:00:00 16.1 2.9 26.3 8 16.3 3.1 26.8 9.5 14.3 2.8 23.3 7.2 82 16 65 300 7.8 0 8 7.5 12/07/2005 18:10:00 14.9 3.6 24 5.7 15 3.6 24.4 6.1 13.4 3.5 24 5.7 82 15 80 300 7.9 0 8.3 7.8 12/07/2005 18:20:00 14.3 2.5 21 8.8 14.3 2.6 21.8 8 12.6 2.6 19.9 7.6 82 14 71 300 8 0 8.3 7.8 12/07/2005 18:30:00 15.9 2.9 22.9 7.6 16.1 3.1 22.9 7.6 14.4 2.7 21.4 7.6 80 14 78 300 8.3 0 8.5 8 12/07/2005 18:40:00 14.3 2.6 22.6 7.6 14.4 2.7 22.9 8.4 13 2.7 22.1 6.8 82 13 97 300 8.4 0 8.8 8.5 12/07/2005 18:50:00 14.7 2.7 21 7.6 14.9 2.7 21.4 7.2 13.5 2.5 21.8 6.8 87 13 81 300 8.4 0 8.5 8.5 12/07/2005 19:00:00 13 3.3 22.6 5.7 13 3.3 22.6 4.6 11.8 3.2 22.1 4.2 88 17 91 300 8.1 0.1 8.5 8 12/07/2005 19:10:00 14.4 3.5 21 6.1 14.5 3.5 22.6 6.1 13 3.3 21 4.6 85 13 91 300 8.1 0 8.5 7.8 12/07/2005 19:20:00 14.4 3.1 26.3 7.6 14.5 3.2 26.3 7.6 13 2.9 23.7 6.8 89 14 92 300 8.2 0 8.5 8 12/07/2005 19:30:00 13.1 3.1 20.2 4.9 13.1 3.2 20.6 4.9 11.7 2.9 20.2 3.8 86 16 93 300 8.1 0 8.3 8 12/07/2005 19:40:00 16.2 3.5 24.8 6.8 16.3 3.6 24.8 7.2 14.5 3.2 24.4 6.8 87 13 92 300 8.3 0 8.5 8.3 12/07/2005 19:50:00 15.9 2.7 22.1 9.1 15.9 2.7 22.1 9.1 14.3 2.7 21.4 6.5 85 13 84 300 8.1 0 8.3 8 12/07/2005 20:00:00 15.7 2.8 24 8.4 15.8 2.8 24 9.5 14.2 2.8 22.6 7.6 86 13 98 300 8.3 0 8.5 8.3 12/07/2005 20:10:00 16.5 3.1 24.4 9.1 16.5 3.1 24.8 8.8 15.1 3.2 24 7.6 88 12 94 300 8.2 0 8.5 8.3 12/07/2005 20:20:00 15.8 3.3 24.4 7.6 15.9 3.5 24.4 7.6 14 3.5 22.9 5.7 89 16 99 300 8.3 0 8.5 8.3 12/07/2005 20:30:00 16.7 3.2 26 9.5 16.8 3.3 26 9.9 14.8 3.3 25.6 6.8 90 14 82 300 8.1 0 8.3 8 12/07/2005 20:40:00 16.5 3.2 24.8 8.8 16.5 3.2 24.8 9.1 14.8 3.1 22.9 7.6 90 13 88 300 8.1 0 8.3 8 12/07/2005 20:50:00 16 3.1 24.4 9.9 16.1 3.1 24.4 9.5 14.6 2.9 24.4 8 91 13 86 300 8 0 8.3 8 12/07/2005 21:00:00 16.2 3.3 23.3 9.1 16.2 3.3 23.7 8.4 14.5 3.2 23.3 6.5 91 13 106 300 8.3 0 8.5 8 12/07/2005 21:10:00 14.9 2.8 22.1 7.6 14.9 2.9 22.6 7.2 13.3 2.8 21 6.5 92 15 107 300 8.4 0 8.5 8.3 12/07/2005 21:20:00 14.7 3.1 24.8 5.3 14.7 3.2 24 5.7 13.3 2.8 20.2 6.1 89 14 85 300 8.5 0 8.8 8.5 12/07/2005 21:30:00 15.2 2.8 22.6 7.6 15.2 2.8 22.6 8 13.8 2.8 21.4 6.8 91 12 93 300 8.9 0 9 8.5 12/07/2005 21:40:00 14.6 3.6 24.4 6.5 14.6 3.6 25.6 4.2 13.6 3.5 22.6 5.7 89 17 90 300 9 0 9 8.8 12/07/2005 21:50:00 12.5 3.3 20.2 4.9 12.6 3.5 20.2 3.4 11.7 3.2 19.5 3.8 87 15 74 300 8.9 0 9 8.8 12/07/2005 22:00:00 13 2.2 19.9 7.2 12.9 2.3 19.5 6.8 12 2.2 17.9 6.5 93 13 84 300 8.9 0 9 8.8 12/07/2005 22:10:00 13.4 2.9 20.6 7.6 13.5 2.9 20.2 7.2 12.3 2.8 21.4 6.1 90 14 87 300 8.9 0 9 8.8 12/07/2005 22:20:00 12.3 2.8 19.9 5.3 12.3 2.8 19.5 4.9 11.1 2.6 19.1 4.9 92 13 77 300 8.9 0 9 8.8 12/07/2005 22:30:00 12.8 2.9 21 7.2 12.8 2.9 20.6 6.5 11.4 3.1 20.2 5.3 95 15 91 300 8.8 0 9 8.8 12/07/2005 22:40:00 12.2 3.3 22.9 4.9 12.2 3.3 22.6 5.3 11 3.2 21.8 5.3 94 15 94 300 8.7 0 9 8.5 12/07/2005 22:50:00 11.9 2.5 18.7 6.1 11.9 2.5 19.1 6.1 10.7 2.4 17.2 4.9 96 14 82 300 8.8 0 9 8.8 12/07/2005 23:00:00 10.8 2.9 18.7 4.9 10.8 2.9 19.5 4.9 9.8 2.8 17.6 4.2 97 15 118 300 8.9 0 9.3 8.5 12/07/2005 23:10:00 10.7 2.7 18.7 4.6 10.7 2.7 19.1 4.6 9.7 2.6 16.8 3.8 98 15 100 300 9 0 9.3 9 12/07/2005 23:20:00 11 2.5 17.9 5.7 11.1 2.5 17.9 5.3 10 2.5 16.8 4.6 102 15 111 300 8.9 0 9 8.8 12/07/2005 23:30:00 11.4 3.5 20.2 4.2 11.4 3.5 20.2 4.2 10.1 3.2 17.9 3.8 100 15 84 300 8.9 0 9 8.8 12/07/2005 23:40:00 11.9 2.7 20.2 5.3 11.8 2.7 20.2 4.9 10.6 2.6 19.9 5.3 92 12 100 300 8.9 0 9 8.8 12/07/2005 23:50:00 12.8 2.4 18.7 6.1 12.8 2.4 19.1 4.6 11.7 2.4 17.9 5.7 88 13 80 300 8.9 0 9 8.8 12/08/2005 00:00:00 10.4 2.8 18.3 4.6 10.4 2.8 17.9 4.6 9.4 2.5 16.4 3 83 18 105 300 8.9 0 9 8.8 12/08/2005 00:10:00 12.5 2.7 19.9 4.9 12.6 2.8 20.6 4.6 11.4 2.6 18.7 4.9 85 16 85 300 8.7 0 8.8 8.5 12/08/2005 00:20:00 11.4 3.2 21.4 4.9 11.5 3.3 21.8 4.6 10.3 2.8 20.6 4.2 88 15 89 300 8.5 0 8.8 8.3 12/08/2005 00:30:00 12 2.8 19.5 4.6 12.1 2.8 19.9 3.8 11 2.7 18.3 5.3 86 17 107 300 8.4 0 8.5 8.3 12/08/2005 00:40:00 11 3.2 18.7 3.4 11.1 3.3 19.9 3.8 9.9 3.2 18.3 2.6 85 20 69 300 8.5 0.1 9 8.3 12/08/2005 00:50:00 12.5 3.2 22.1 5.3 12.6 3.2 21.8 4.9 11.4 2.9 19.9 3 88 17 90 300 8.9 0 9 8.8 12/08/2005 01:00:00 12.8 2.8 20.2 5.3 12.8 2.9 20.6 6.1 11.8 2.8 19.5 6.1 91 15 87 300 8.6 0.1 8.8 8.5 12/08/2005 01:10:00 11.8 2.9 19.1 5.7 11.8 2.9 19.5 5.7 10.6 2.7 17.6 4.6 87 15 88 300 8.4 0 8.5 8.5 12/08/2005 01:20:00 11 2.6 18.3 5.3 11 2.7 18.3 4.6 9.9 2.8 18.3 4.2 87 15 94 300 8.5 0 8.5 8.3 12/08/2005 01:30:00 10.4 2.6 19.5 4.9 10.5 2.7 19.5 4.9 9.5 2.6 20.2 4.2 99 17 101 300 8.5 0 8.8 8.3 12/08/2005 01:40:00 11.2 2.6 17.2 4.2 11.3 2.6 17.6 4.6 10.3 2.6 16.4 3.8 89 14 84 300 8.7 0 9 8.8 12/08/2005 01:50:00 11.6 2.8 20.6 5.3 11.6 2.8 20.2 4.9 10.5 2.7 20.6 4.2 91 15 117 300 8.7 0 9 8.5 12/08/2005 02:00:00 11.4 3.1 19.5 5.7 11.4 3.1 19.9 5.3 10.4 2.9 19.9 4.2 97 17 103 300 8.9 0 9 8.5 12/08/2005 02:10:00 11 2.7 19.5 3.8 11.1 2.8 18.3 4.2 10.3 2.4 17.9 5.3 92 15 98 300 9 0 9 9 12/08/2005 02:20:00 11.6 2.5 17.9 5.3 11.6 2.5 17.9 4.9 10.5 2.3 17.2 4.9 93 15 95 300 9.1 0 9.3 9 12/08/2005 02:30:00 11 2.4 17.2 6.5 11.1 2.5 17.2 5.7 10.1 2.5 16.4 4.2 88 15 82 300 9.4 0 9.6 9.3 12/08/2005 02:40:00 10 2 16.1 5.3 10.1 2 15.6 4.9 9.1 1.8 14.1 4.2 91 16 100 300 9.4 0 9.6 9.3 12/08/2005 02:50:00 11.7 2.2 17.9 6.8 11.8 2.3 18.7 6.5 10.7 2.4 17.2 6.1 87 15 77 300 9.4 0 9.6 9.3 12/08/2005 03:00:00 10 2.1 16.8 5.7 10 2.1 16.8 5.3 9.1 2 16.1 4.2 90 13 96 300 9.6 0 9.6 9.6 12/08/2005 03:10:00 9.2 1.8 14.1 4.6 9.2 1.8 13.7 4.2 8.3 1.8 13.7 4.9 88 15 85 300 9.6 0 9.8 9.6 12/08/2005 03:20:00 9.4 1.9 15.3 4.6 9.5 1.9 15.3 4.6 8.4 1.9 13.7 4.2 90 14 102 300 9.5 0 9.6 9.6 12/08/2005 03:30:00 10.2 2.9 19.1 3.8 10.2 2.9 19.9 3.4 9.2 2.7 17.9 4.6 88 16 112 300 9.5 0 9.6 9.6 12/08/2005 03:40:00 9.6 2 14.9 4.2 9.7 2 14.5 4.6 8.8 1.7 13.7 4.9 94 14 111 300 9.5 0 9.6 9.3 12/08/2005 03:50:00 9.5 2 15.6 6.1 9.6 1.9 15.3 6.5 8.5 2 14.5 3.8 98 13 108 300 9.6 0.1 9.8 9.3 12/08/2005 04:00:00 7.7 1.6 12.6 3.8 7.7 1.6 13 4.6 6.8 1.5 11.8 3 104 16 87 300 10 0 10.3 9.8 12/08/2005 04:10:00 4.2 1.5 8.8 1.5 4.2 1.5 8.8 1.5 3.6 1.3 9.1 1.5 140 24 103 300 9.6 0.4 10.1 8.8 12/08/2005 04:20:00 3.5 1.3 7.2 1.1 3.5 1.3 7.2 1.1 3 1.2 6.5 1.1 130 35 99 300 7.8 0.4 8.8 7.3 12/08/2005 04:30:00 4.4 1.2 8 1.9 4.3 1.2 7.6 1.9 3.9 1 7.2 1.9 93 17 109 300 8.9 0.4 9.6 8.3 12/08/2005 04:40:00 4.3 1.3 9.1 1.5 4.3 1.4 9.1 1.1 3.7 1.5 7.6 1.1 133 39 118 300 9.4 0.6 9.8 7.8 12/08/2005 04:50:00 3.2 0.9 4.6 0.4 3.2 0.8 4.6 0.4 2.6 0.8 3.8 0.4 176 19 163 300 6.6 0.5 7.8 6 12/08/2005 05:00:00 2.9 1.2 6.8 1.1 2.7 1.3 7.2 0.4 2.6 1.2 5.7 0.4 101 30 111 300 6.9 0.8 8.3 6 12/08/2005 05:10:00 3.9 1.3 7.6 1.1 3.9 1.4 7.6 0.4 3.4 1.4 6.5 0.4 80 22 85 300 8.5 0.4 9 7.8 12/08/2005 05:20:00 3.9 1.5 8.8 0.7 3.9 1.6 9.1 0.4 3.4 1.4 7.6 0.4 96 19 128 300 9.3 0.2 9.6 9 12/08/2005 05:30:00 5.2 1.7 9.5 1.1 5.2 1.7 9.5 0.7 4.6 1.6 9.5 1.9 116 22 106 300 9.5 0 9.6 9.3 12/08/2005 05:40:00 5.1 1.2 8.4 2.6 5.1 1.2 8.4 2.6 4.1 1 6.8 1.9 114 12 117 300 8.8 0.2 9.3 8.5 12/08/2005 05:50:00 3.5 1.1 6.1 1.5 3.5 1.1 6.5 1.1 3 0.9 5.3 0.7 127 24 119 300 8.4 0 8.8 8.3 12/08/2005 06:00:00 5.8 1.4 10.3 3.4 5.7 1.4 10.3 3 5.2 1.3 9.5 2.6 101 19 97 300 9.4 0.5 10.1 8.5 12/08/2005 06:10:00 6.9 2.1 13.3 3 6.9 2.1 13 2.6 5.6 2 12.2 1.9 121 17 126 300 10.1 0 10.3 9.8 12/08/2005 06:20:00 4.4 1.8 9.5 0.7 4.3 1.9 9.9 0.4 3.8 1.7 8.4 1.1 128 27 85 300 10.1 0 10.3 9.8 12/08/2005 06:30:00 2.7 0.7 4.9 1.1 2.7 0.8 4.9 1.1 2.4 0.7 4.2 1.1 124 56 98 300 9.4 0.1 9.8 9 12/08/2005 06:40:00 4.2 2.2 9.1 0.4 4.1 2.3 8.8 0.4 3.8 2 8.8 0.7 106 26 89 300 9.8 0 10.1 9.3 12/08/2005 06:50:00 3.1 1.4 6.8 0.4 3 1.5 7.2 0.4 2.5 1.2 6.1 0.4 105 41 91 300 9.8 0 10.1 9.6 12/08/2005 07:00:00 4.2 2 9.9 0.4 4.1 2.1 9.5 0.4 3.7 1.9 8.8 0.4 106 33 117 300 9.6 0 9.8 9.6 12/08/2005 07:10:00 5.8 1.2 9.1 2.6 5.8 1.3 9.1 2.6 5.4 1.1 9.1 2.6 100 20 105 300 9.8 0 9.8 9.6 12/08/2005 07:20:00 5.6 1.6 9.9 2.3 5.5 1.5 9.1 2.6 5 1.4 9.1 2.3 111 17 111 300 9.6 0 9.8 9.6 12/08/2005 07:30:00 6.1 1.3 10.7 3 6.1 1.3 10.7 2.6 5.6 1.5 9.9 2.3 101 18 103 300 9.4 0 9.6 9 12/08/2005 07:40:00 7 1.7 11.8 3.8 7 1.7 11.8 3.8 6.3 1.7 11.5 3 100 17 79 300 9 0 9.3 9 12/08/2005 07:50:00 7.3 1.9 13.3 3.4 7.3 1.9 13.3 3.4 6.7 1.8 11.5 3 98 13 111 300 8.9 0 9 8.5 12/08/2005 08:00:00 6.7 1.2 10.3 4.2 6.7 1.3 10.3 3.8 6.2 1.3 11.1 3.4 100 17 82 300 8.5 0 8.8 8.3 12/08/2005 08:10:00 5.6 2 11.1 1.1 5.6 2 10.3 0.7 5.1 1.6 9.9 2.3 101 16 122 300 7.8 0.2 8.3 7.5 12/08/2005 08:20:00 6.1 1.5 9.9 2.6 6.2 1.6 10.7 2.3 5.6 1.4 8.8 2.3 98 19 97 300 8 0.1 8.3 7.5 12/08/2005 08:30:00 5.7 1.2 8.8 3 5.8 1.3 9.1 2.6 5.3 1.3 8.4 2.3 94 15 107 300 8.2 0 8.5 8.3 12/08/2005 08:40:00 7.4 1.7 13.3 3.8 7.5 1.7 13.7 4.2 6.7 1.7 13 3.4 93 14 88 300 8.4 0 8.5 8.3 12/08/2005 08:50:00 5.6 1.5 8.8 1.9 5.6 1.4 9.1 1.9 5.1 1.3 8.4 1.9 101 18 113 300 8.4 0 8.5 8.3 12/08/2005 09:00:00 5.4 1.7 10.7 1.9 5.5 1.8 10.7 2.3 5 1.8 11.1 1.1 107 22 111 300 8.3 0 8.5 8.3 12/08/2005 09:10:00 4.6 1.3 9.1 1.5 4.6 1.3 9.1 1.5 3.7 1.3 9.5 1.9 134 18 92 300 8.3 0 8.5 8.3 12/08/2005 09:20:00 5.8 2 11.8 1.1 5.8 2 11.8 1.9 4.9 1.8 9.9 1.1 113 22 100 300 8.4 0.1 8.8 8.3 12/08/2005 09:30:00 3.7 1.4 8.4 0.4 3.7 1.5 8.4 0.4 3.3 1.4 7.6 0.7 127 32 112 300 8.4 0 8.5 8.3 12/08/2005 09:40:00 3.9 1.7 8.8 1.5 3.9 1.7 9.1 1.1 3.6 1.7 8.4 1.1 117 18 96 300 8.3 0 8.5 8 12/08/2005 09:50:00 4.7 1.7 10.3 1.5 4.6 1.7 10.3 0.7 4 1.7 9.9 1.5 120 26 103 300 7.7 0.2 8 7.3 12/08/2005 10:00:00 4.4 1.1 7.6 1.5 4.4 1.1 7.6 1.1 3.8 1 6.5 1.1 123 28 105 300 7.3 0.5 8 6.7 12/08/2005 10:10:00 3.3 1.2 7.2 1.1 3.3 1.2 6.8 1.1 2.9 1.2 6.8 1.1 147 38 104 300 5.4 0.5 6.7 4.8 12/08/2005 10:20:00 4.1 1.2 6.8 1.5 4.1 1.2 6.5 1.5 3.3 1.1 6.5 1.1 142 28 110 300 5.4 0 5.7 5 12/08/2005 10:30:00 3.5 1.2 7.2 1.1 3.5 1.2 6.8 1.1 2.8 1 6.1 0.4 129 35 122 300 5.9 0.5 6.7 5 12/08/2005 10:40:00 1.8 1 4.6 0.4 1.7 1 4.6 0.4 1.4 0.8 4.2 0.4 159 69 84 300 6.2 0.1 7 6 12/08/2005 10:50:00 3.1 1.2 6.1 0.7 3 1.3 5.7 0.4 2.4 1.1 5.7 0.4 109 36 95 300 7.6 0.2 8.3 7 12/08/2005 11:00:00 3.6 0.9 6.5 1.5 3.6 0.9 6.5 1.1 3.2 0.9 6.1 1.5 102 12 100 300 8.5 0.2 8.8 8 12/08/2005 11:10:00 4.4 2.1 8.4 0.7 4.4 2.2 8 0.7 4.1 1.8 7.6 0.7 99 17 113 300 8.9 0.2 9.3 8.5 12/08/2005 11:20:00 4.5 1.2 7.6 1.9 4.5 1.2 7.6 1.9 4.2 1 7.6 1.9 89 18 91 300 9.4 0 9.6 9.3 12/08/2005 11:30:00 5.2 1.6 9.1 1.5 5.2 1.5 8.8 1.5 4.6 1.5 8.4 1.1 95 22 91 300 9.4 0 9.6 9 12/08/2005 11:40:00 3.2 1.4 7.6 0.4 3.1 1.4 7.2 0.4 2.8 1.3 6.1 0.4 112 22 100 300 9.4 0 9.6 9 12/08/2005 11:50:00 3.5 0.9 6.1 1.1 3.5 1 6.1 1.5 3.2 0.9 5.3 1.1 102 12 121 300 8.7 0.1 9 8.5 12/08/2005 12:00:00 4.5 1 7.2 2.6 4.5 1 6.8 2.6 4 0.9 6.1 1.9 102 14 86 300 8.1 0.1 8.5 7.8 12/08/2005 12:10:00 5.3 1.1 8.4 2.6 5.3 1.2 8.8 2.6 4.6 1.2 7.6 1.9 96 13 103 300 8.5 0.3 9 8 12/08/2005 12:20:00 6 1.7 11.8 2.6 6.1 1.7 10.3 2.3 5.5 1.7 10.3 2.6 90 15 100 300 9.2 0.1 9.6 9 12/08/2005 12:30:00 6.7 1.4 11.5 3.8 6.8 1.5 11.5 3.8 6.2 1.3 11.1 3.4 91 13 114 300 9.2 0.1 9.6 9 12/08/2005 12:40:00 6.7 1.4 9.9 3 6.7 1.4 9.9 3.4 6 1.5 9.5 2.6 89 15 90 300 9 0 9 8.8 12/08/2005 12:50:00 6.3 1.2 9.9 3.8 6.3 1.2 9.9 3.8 5.7 1.2 9.1 3.4 89 13 94 300 9 0 9.3 9 12/08/2005 13:00:00 6.8 1.6 11.5 3.4 6.8 1.5 11.5 3 6 1.4 9.5 3.4 95 15 74 300 9.2 0 9.3 9 12/08/2005 13:10:00 6.9 2.1 11.8 3 6.9 2.1 12.6 2.6 6.2 2.2 12.2 1.9 90 16 91 300 9.3 0 9.6 9.3 12/08/2005 13:20:00 6.5 1.5 10.7 3 6.6 1.5 10.7 2.3 5.9 1.3 9.5 3 104 15 121 300 9.4 0 9.6 9.3 12/08/2005 13:30:00 5.5 1.2 9.5 2.6 5.5 1.2 9.1 2.6 4.9 1.2 8.8 2.3 102 17 119 300 9.4 0 9.6 9.3 12/08/2005 13:40:00 6.4 1.7 10.3 3.4 6.4 1.7 11.1 3.4 6 1.5 10.3 3 98 13 118 300 9.6 0 9.8 9.3 12/08/2005 13:50:00 5.9 1.3 9.9 3 6 1.3 9.9 3 5.4 1.2 8.8 2.6 92 16 100 300 9.6 0 9.8 9.6 12/08/2005 14:00:00 7.8 1.2 11.5 4.9 7.8 1.1 11.5 4.9 7 1.2 10.7 4.2 91 12 82 300 9.8 0 10.1 9.6 12/08/2005 14:10:00 5.5 1.1 8 3 5.5 1.1 8.4 3 5 1.1 8 2.6 85 16 79 300 9.6 0 9.8 9.6 12/08/2005 14:20:00 6.8 1.2 10.3 4.2 6.9 1.2 10.3 4.2 6 1.2 9.5 1.9 110 15 116 300 9.6 0 9.8 9.6 12/08/2005 14:30:00 5.7 1.3 9.1 2.6 5.7 1.4 9.1 2.3 5.1 1.3 7.6 2.3 101 18 90 300 9.6 0 9.8 9.3 12/08/2005 14:40:00 6 1.5 9.9 2.6 6 1.5 11.1 2.6 5.5 1.5 9.9 1.9 104 16 100 300 9.4 0 9.6 9.3 12/08/2005 14:50:00 7.2 1.6 11.5 3.8 7.2 1.6 10.7 3.4 6.2 1.6 9.5 2.6 110 13 105 300 9.2 0 9.3 9.3 12/08/2005 15:00:00 5.9 1.5 9.9 2.6 6 1.5 10.3 3 5.4 1.5 9.1 2.6 102 16 94 300 9.3 0 9.6 9 12/08/2005 15:10:00 5.4 1.9 9.5 1.5 5.3 1.9 9.9 1.1 4.9 1.9 11.1 1.5 97 17 114 300 9 0 9.3 9 12/08/2005 15:20:00 7.9 1.7 12.6 3.8 7.9 1.7 13.3 3.4 7 1.7 11.5 2.3 101 17 101 300 9.1 0 9.3 9 12/08/2005 15:30:00 8 1.5 13 5.3 8.1 1.5 12.6 4.9 7.5 1.5 12.2 3.4 97 13 90 300 9.2 0 9.3 9 12/08/2005 15:40:00 8 1.6 12.6 4.2 8 1.6 13 4.6 7.1 1.5 11.8 3.8 96 13 109 300 9.2 0 9.3 9 12/08/2005 15:50:00 8.1 1.5 12.2 4.6 8.1 1.5 12.2 4.6 7.2 1.5 11.1 3.4 94 11 106 300 9.2 0 9.3 9 12/08/2005 16:00:00 7.8 1.4 10.7 3.8 7.9 1.4 11.1 4.6 6.8 1.5 11.1 3.4 95 14 89 300 9.1 0.1 9.3 9 12/08/2005 16:10:00 8.2 1.7 13 3.8 8.2 1.7 13.3 3.4 7.4 1.7 13 3 97 13 87 300 8.9 0 9 8.8 12/08/2005 16:20:00 8.3 1.7 13 4.6 8.4 1.8 13.3 4.2 7.4 1.9 14.5 2.6 93 15 100 300 8.9 0 9 8.8 12/08/2005 16:30:00 8.4 1.6 13.3 4.6 8.3 1.6 13 4.9 7.5 1.7 13.7 4.2 94 17 88 300 8.7 0 8.8 8.8 12/08/2005 16:40:00 8.7 2.3 15.6 4.2 8.8 2.3 14.9 4.2 7.8 2.2 14.1 3.8 94 15 67 300 8.7 0 8.8 8.8 12/08/2005 16:50:00 8.8 2.3 14.5 4.6 8.8 2.3 14.9 4.2 8.2 2.2 14.1 3.4 97 13 88 300 8.9 0 9 8.8 12/08/2005 17:00:00 10 2.1 16.1 4.2 10 2.2 16.4 4.2 9.3 2.3 15.6 3.8 99 15 85 300 8.8 0 9 8.5 12/08/2005 17:10:00 10.4 2.2 16.1 4.2 10.3 2.3 16.8 4.2 9.4 2.1 15.6 3 96 15 103 300 8.7 0 9 8.8 12/08/2005 17:20:00 10.2 2.3 17.9 5.7 10.2 2.3 17.6 5.7 9.2 2.2 16.8 4.2 94 15 96 300 8.7 0 8.8 8.8 12/08/2005 17:30:00 9.6 2.4 17.9 4.6 9.7 2.3 17.9 4.9 8.8 2.2 15.3 3.4 95 14 94 300 8.7 0 8.8 8.5 12/08/2005 17:40:00 9.6 1.9 14.5 5.3 9.7 1.9 14.1 4.9 8.7 2.1 13.3 3.8 94 14 91 300 8.7 0 8.8 8.8 12/08/2005 17:50:00 9.1 1.7 13.3 4.2 9 1.7 13 4.2 8.1 1.7 12.6 3.4 93 14 122 300 8.9 0 9 8.8 12/08/2005 18:00:00 9.5 1.8 14.1 5.7 9.6 1.8 14.1 5.7 8.8 1.8 13.3 4.6 86 13 93 300 9 0 9.3 9 12/08/2005 18:10:00 7.4 1.7 12.2 3 7.4 1.7 12.2 3 6.7 1.6 11.5 3 100 17 100 300 9 0 9.3 9 12/08/2005 18:20:00 8.1 2.2 14.9 3.4 8.1 2.2 15.3 4.2 7.1 1.8 12.6 3 91 17 90 300 9.1 0 9.3 9 12/08/2005 18:30:00 7.2 1.7 11.5 3 7.2 1.7 11.8 3 6.5 1.7 10.7 1.9 100 17 79 300 9.2 0 9.3 9 12/08/2005 18:40:00 7.9 2.1 13.3 3.4 7.8 2.2 13.3 3 6.7 2.2 13 2.3 88 15 84 300 9.3 0 9.6 9 12/08/2005 18:50:00 7.7 1.5 13.3 4.2 7.7 1.5 13.3 4.6 7.1 1.4 11.5 4.2 89 15 89 300 9.4 0 9.6 9.3 12/08/2005 19:00:00 8.8 1.7 13 4.2 8.8 1.6 13 4.6 7.8 1.6 13 4.2 89 15 91 300 9.4 0 9.6 9.3 12/08/2005 19:10:00 8.6 1.9 14.1 4.2 8.6 1.9 14.1 4.2 7.9 1.8 13.3 4.2 96 15 110 300 9.2 0 9.3 9 12/08/2005 19:20:00 7.4 1.5 11.8 2.6 7.5 1.5 11.8 3 6.8 1.5 10.7 3 101 17 79 300 9.1 0 9.3 9 12/08/2005 19:30:00 8.9 2.3 14.1 4.2 9 2.3 14.5 4.2 8.2 2.2 13.3 3.8 97 14 107 300 9.1 0 9.3 9 12/08/2005 19:40:00 9.4 1.9 14.5 4.9 9.5 1.9 14.9 4.9 8.7 1.8 13.3 4.2 91 13 85 300 9 0 9.3 9 12/08/2005 19:50:00 9.6 2.4 16.8 4.6 9.6 2.4 16.4 4.2 8.7 2.2 14.1 3.4 91 18 115 300 8.9 0 9 8.8 12/08/2005 20:00:00 9.2 2.2 14.9 4.6 9.2 2.2 14.9 4.6 8.4 2.1 16.8 5.3 93 13 88 300 8.8 0 9 8.8 12/08/2005 20:10:00 9.3 1.9 14.1 4.6 9.3 1.8 14.1 4.9 8.5 1.8 13.7 3.4 91 15 88 300 8.7 0 9 8.5 12/08/2005 20:20:00 8.7 1.8 13.3 3.8 8.6 1.8 13 3.8 7.8 1.8 13 3.4 96 15 81 300 8.7 0 9 8.5 12/08/2005 20:30:00 10.5 2.3 16.1 3.4 10.4 2.3 16.1 3.4 9.3 2.3 14.5 3 92 14 97 300 8.7 0 8.8 8.5 12/08/2005 20:40:00 10.8 1.9 16.8 5.7 10.8 2 16.4 6.1 9.6 1.9 16.4 5.3 92 13 97 300 8.6 0 8.8 8.5 12/08/2005 20:50:00 9.9 2.6 17.6 3.8 9.9 2.7 17.6 4.2 8.8 2.5 16.1 3 90 15 91 300 8.7 0 8.8 8.5 12/08/2005 21:00:00 9.3 1.9 13.7 4.6 9.3 2 14.5 4.9 8.2 1.9 14.5 4.6 95 17 79 300 8.5 0 8.8 8.5 12/08/2005 21:10:00 9.3 2.1 14.5 4.6 9.4 2.2 14.5 4.9 8.4 1.9 13.7 4.2 94 16 76 300 8.6 0 8.8 8.5 12/08/2005 21:20:00 9.6 2 15.6 4.9 9.5 2 15.3 4.9 8.4 2 13.7 3.8 91 13 77 300 8.5 0 8.8 8.5 12/08/2005 21:30:00 9 1.6 13.7 5.7 9 1.7 13.7 5.3 8.4 1.7 13 3.8 94 12 85 300 8.7 0 9 8.5 12/08/2005 21:40:00 8.2 2.4 14.1 3.8 8.2 2.4 13.7 3.4 7.6 2.1 14.5 3.4 95 13 81 300 8.7 0 9 8.8 12/08/2005 21:50:00 8.8 2.8 16.4 3.8 8.9 2.8 16.4 3.8 8.1 2.6 15.6 3 92 12 94 300 9 0 9 8.8 12/08/2005 22:00:00 8.8 1.5 12.2 5.3 8.8 1.5 12.2 4.6 7.9 1.6 12.2 4.9 96 14 91 300 8.9 0 9 8.8 12/08/2005 22:10:00 8.2 1.3 11.5 4.9 8.2 1.3 11.1 4.9 7.4 1.3 10.7 3.4 99 14 90 300 8.8 0 9 8.8 12/08/2005 22:20:00 8.6 1.9 13 3.4 8.6 1.9 12.2 3.8 7.8 1.9 11.8 3 94 13 85 300 8.9 0 9 8.8 12/08/2005 22:30:00 9.1 1.7 13.3 4.2 9.2 1.6 13.7 4.9 8.3 1.7 13.3 4.2 83 12 83 300 9 0 9 9 12/08/2005 22:40:00 9 1.5 13.3 4.6 9 1.5 14.1 5.3 7.7 1.6 11.5 3.4 78 13 82 300 9.1 0 9.3 9 12/08/2005 22:50:00 8.5 1.7 13.7 4.6 8.6 1.8 14.1 4.2 7.7 1.7 12.6 4.2 80 14 76 300 9.3 0 9.3 9 12/08/2005 23:00:00 8.6 1.6 12.2 4.6 8.7 1.7 12.6 4.9 7.6 1.7 12.2 3.4 78 12 75 300 9.3 0 9.6 9 12/08/2005 23:10:00 8.2 1.4 11.1 4.9 8.3 1.4 11.8 4.9 6.9 1.5 10.7 3.4 72 12 57 300 9.4 0 9.6 9.3 12/08/2005 23:20:00 8.7 1.9 13 4.2 8.8 2 13.3 4.6 8 1.8 12.6 3.4 81 13 77 300 9.3 0 9.6 9.3 12/08/2005 23:30:00 7.1 1.4 11.1 3.8 7.2 1.5 11.5 3.8 6.6 1.4 11.1 3.4 88 15 82 300 9.2 0 9.3 9 12/08/2005 23:40:00 7.8 1.4 11.5 4.9 7.9 1.5 11.8 4.6 7.1 1.5 11.1 3 82 13 84 300 9.2 0 9.3 9 12/08/2005 23:50:00 7.4 1.8 12.6 3.8 7.4 1.8 13 3.8 6.7 1.8 12.2 3.4 81 16 65 300 9.1 0 9.3 9 12/09/2005 00:00:00 5.8 1.5 9.9 2.6 5.8 1.6 9.9 3 5.4 1.6 9.9 1.1 86 23 97 300 9 0 9 9 12/09/2005 00:10:00 5.7 2 12.6 1.1 5.8 2 12.6 1.5 5 1.6 9.9 1.1 84 24 67 300 9 0 9 9 12/09/2005 00:20:00 8 2.5 16.8 2.3 8 2.5 15.6 1.9 7.2 2.2 13.3 2.6 89 20 91 300 9 0 9.3 9 12/09/2005 00:30:00 9.7 2.7 17.6 3.4 9.8 2.6 17.6 3 9 2.4 16.4 3 89 16 94 300 9.2 0 9.3 9 12/09/2005 00:40:00 9.9 2.1 15.6 4.6 10 2.1 16.1 4.9 9 2.2 15.3 4.9 86 14 90 300 9 0 9.3 8.8 12/09/2005 00:50:00 10.5 2.5 17.2 4.2 10.6 2.5 17.6 4.6 9.5 2.5 16.1 4.6 86 12 77 300 8.8 0 9 8.8 12/09/2005 01:00:00 10.7 2.5 17.9 5.7 10.9 2.5 17.9 6.1 9.9 2.4 16.4 4.6 84 13 83 300 8.7 0 9 8.5 12/09/2005 01:10:00 10.5 2.6 18.3 4.6 10.6 2.6 18.7 4.9 9.4 2.5 18.7 4.2 89 15 87 300 8.6 0 8.8 8.5 12/09/2005 01:20:00 11.4 2.9 17.9 4.2 11.5 3.1 18.3 3.8 10.3 2.7 17.2 3.8 88 15 66 300 8.6 0 8.8 8.5 12/09/2005 01:30:00 10.9 2.2 16.4 6.1 11 2.3 16.4 6.1 9.8 2.2 16.1 4.6 90 14 99 300 8.5 0 8.8 8.5 12/09/2005 01:40:00 10.8 2.6 16.8 5.3 10.9 2.6 16.4 5.7 10 2.6 16.4 4.2 91 15 85 300 8.7 0 8.8 8.5 12/09/2005 01:50:00 11.8 2.6 19.5 6.5 11.7 2.6 19.5 5.7 10.7 2.6 17.9 5.3 88 14 79 300 8.7 0 8.8 8.8 12/09/2005 02:00:00 11.7 2.5 19.5 4.9 11.8 2.6 19.1 4.2 10.7 2.3 16.8 6.1 88 15 80 300 8.7 0 8.8 8.5 12/09/2005 02:10:00 11.2 2.7 20.2 5.7 11.3 2.7 20.6 5.7 10.3 2.7 19.5 4.9 92 15 72 300 8.8 0 9 8.8 12/09/2005 02:20:00 11 1.7 16.4 6.5 11.1 1.7 16.1 6.8 10.1 1.8 15.3 4.9 86 14 121 300 8.7 0 8.8 8.5 12/09/2005 02:30:00 11.6 2.2 17.2 6.5 11.6 2.2 17.6 6.1 10.4 2.3 16.4 5.3 84 13 87 300 8.5 0 8.8 8.5 12/09/2005 02:40:00 11.2 2.5 19.1 4.9 11.3 2.5 19.1 4.6 10.5 2.4 16.8 5.3 86 15 78 300 8.5 0 8.8 8.5 12/09/2005 02:50:00 10.7 2.3 16.8 4.2 10.8 2.5 17.2 3.8 9.9 2.5 17.6 3.8 87 15 84 300 8.4 0 8.5 8.5 12/09/2005 03:00:00 10 2.5 15.6 4.2 10 2.6 16.1 4.9 9.3 2.6 16.4 3.8 83 16 88 300 8.6 0 8.8 8.5 12/09/2005 03:10:00 11.2 2.6 17.6 4.6 11.2 2.7 17.2 4.9 10.3 2.5 17.2 4.2 84 13 85 300 8.6 0 8.8 8.5 12/09/2005 03:20:00 10.1 2.9 17.2 3.4 10.2 2.8 17.9 3.8 9.3 2.6 16.4 3.4 88 15 76 300 8.8 0 9 8.8 12/09/2005 03:30:00 10.2 1.7 15.6 6.1 10.2 1.7 15.6 5.7 9.5 1.7 14.5 3.8 89 14 103 300 8.7 0 8.8 8.5 12/09/2005 03:40:00 9.8 2.6 17.9 4.6 9.8 2.6 18.7 5.3 8.9 2.5 18.3 4.9 92 16 96 300 8.8 0 9 8.8 12/09/2005 03:50:00 8.6 2.2 16.4 4.6 8.6 2.3 15.6 4.6 7.8 2.1 16.1 4.2 95 16 90 300 8.9 0 9 8.8 12/09/2005 04:00:00 5.8 1.7 10.7 2.6 5.9 1.7 10.7 2.6 5.1 1.8 11.1 1.9 106 18 84 300 8.9 0.1 9 8.5 12/09/2005 04:10:00 9.2 2.8 17.2 4.2 9.2 2.8 17.6 4.2 8.1 2.7 16.1 1.9 100 19 88 300 8.9 0.1 9 8.5 12/09/2005 04:20:00 12.7 2.6 19.1 5.7 12.8 2.7 19.1 4.9 11.3 2.5 17.6 4.9 86 13 86 300 9.1 0 9.3 9 12/09/2005 04:30:00 11.3 2.1 16.4 4.9 11.4 2.2 16.4 5.3 10.2 2.2 15.3 4.6 86 13 76 300 9 0 9.3 9 12/09/2005 04:40:00 11.5 2.1 16.8 6.1 11.6 2.2 17.6 6.5 10.4 2.1 15.6 5.7 87 15 79 300 8.9 0 9 8.8 12/09/2005 04:50:00 11.6 2.2 17.2 6.8 11.7 2.2 17.2 7.2 10.3 2.3 17.2 4.2 86 15 94 300 8.7 0 9 8.8 12/09/2005 05:00:00 12.3 2.8 19.9 5.3 12.3 2.9 20.6 4.2 11.1 2.6 18.3 5.3 92 15 96 300 8.6 0 8.8 8.5 12/09/2005 05:10:00 13.5 2.6 21.8 7.6 13.6 2.6 21.4 7.2 12.4 2.4 18.7 7.2 92 13 97 300 8.3 0 8.5 8 12/09/2005 05:20:00 12 2.9 20.6 5.7 12 3.1 20.2 6.1 11.1 2.8 20.2 5.3 93 15 74 300 8.1 0 8.3 7.8 12/09/2005 05:30:00 11.9 3.6 20.2 4.6 11.8 3.6 19.9 3.8 11 3.6 21 4.6 93 17 76 300 8.2 0 8.5 8 12/09/2005 05:40:00 12.4 2.6 20.2 5.7 12.5 2.7 20.2 5.7 11.2 2.7 19.9 5.3 89 12 94 300 8.1 0 8.5 8 12/09/2005 05:50:00 11.5 2.4 16.8 6.1 11.6 2.5 16.4 6.5 10.5 2.5 17.2 5.7 89 12 100 300 8.3 0 8.5 8.3 12/09/2005 06:00:00 12 3.5 20.2 5.3 12 3.5 21 4.9 11 3.3 19.5 3.4 87 17 100 300 8.3 0 8.5 8.3 12/09/2005 06:10:00 12.7 3.1 21 5.7 12.8 3.2 21.4 6.8 11.5 2.9 20.6 5.7 85 15 88 300 8.4 0 8.5 8.5 12/09/2005 06:20:00 13.2 2.9 22.1 6.5 13.3 2.9 21.8 6.1 12.1 2.9 19.9 4.9 86 16 90 300 8.2 0.1 8.5 8 12/09/2005 06:30:00 13.2 2.9 21 5.7 13.3 2.9 21.4 6.1 12 2.9 19.9 6.1 87 15 71 300 7.8 0 8 7.5 12/09/2005 06:40:00 13.9 2.9 21 6.1 14 2.9 21.4 5.3 12.6 3.1 20.2 6.1 87 13 79 300 7.6 0.1 7.8 7.3 12/09/2005 06:50:00 13.4 2.9 21 5.7 13.6 2.9 20.6 5.7 12.4 2.7 19.1 6.1 84 14 85 300 8 0 8 7.8 12/09/2005 07:00:00 13.8 2.8 20.6 6.1 13.9 2.8 20.6 6.8 12.6 2.8 19.5 5.7 84 15 85 300 7.7 0 8 7.5 12/09/2005 07:10:00 14.6 2.8 21.8 8 14.6 2.9 21.8 7.6 12.8 2.9 21.8 6.1 85 13 77 300 7.8 0 7.8 7.5 12/09/2005 07:20:00 13.1 3.5 21.4 5.3 13.2 3.5 21.4 5.3 11.8 3.2 19.9 3.8 82 13 83 300 7.6 0.1 7.8 7.3 12/09/2005 07:30:00 11.9 2.5 18.3 5.7 12.1 2.5 18.7 5.3 10.7 2.2 16.1 3.8 76 14 68 300 7.7 0 7.8 7.5 12/09/2005 07:40:00 11.9 2.7 19.1 6.1 12 2.8 19.5 4.9 10.5 2.6 19.1 4.9 71 17 62 300 7.8 0 8 7.8 12/09/2005 07:50:00 12.8 2.6 18.7 6.1 12.9 2.7 19.5 6.8 10.9 2.6 17.6 3.8 74 16 113 300 8 0 8.3 7.8 12/09/2005 08:00:00 12.6 2.6 19.5 6.8 12.7 2.6 19.9 5.7 11.1 2.7 17.9 4.9 80 15 70 300 8.3 0.1 8.5 8 12/09/2005 08:10:00 12.1 2.3 18.3 6.5 12.2 2.4 18.7 6.8 10.9 2.3 16.4 5.3 77 15 63 300 8.6 0 9 8.5 12/09/2005 08:20:00 12.3 2.4 18.3 6.8 12.4 2.5 17.9 6.5 11.1 2.3 17.2 4.2 82 16 80 300 8.8 0 9 8.8 12/09/2005 08:30:00 10.9 2.1 16.4 5.3 11 2.1 16.4 6.5 9.9 2.1 16.1 4.6 77 15 70 300 8.8 0 9 8.8 12/09/2005 08:40:00 9.6 2.1 14.5 3.8 9.7 2.1 15.3 4.2 8.6 2.1 16.1 3 73 16 64 300 8.6 0 8.8 8.5 12/09/2005 08:50:00 11.3 2.7 17.9 5.7 11.5 2.7 17.9 6.1 10.1 2.5 18.3 5.3 77 14 77 300 8.4 0 8.5 8.5 12/09/2005 09:00:00 10 2.2 16.1 4.2 10 2.3 16.1 3.8 8.9 2.2 14.1 3.4 73 15 61 300 8.5 0 8.5 8.3 12/09/2005 09:10:00 9.8 1.9 16.4 3.8 9.9 2 16.1 3.4 8.5 1.8 14.5 3.8 72 16 88 300 8.4 0 8.5 8.3 12/09/2005 09:20:00 9.7 2.4 17.2 3 9.7 2.5 18.7 3.4 8.6 2.3 16.1 4.2 74 15 57 300 8.4 0 8.5 8.5 12/09/2005 09:30:00 10.6 2.2 16.8 5.7 10.7 2.2 16.4 5.7 9.5 2.1 15.6 3.8 75 14 67 300 8.3 0 8.5 8.3 12/09/2005 09:40:00 9 2.4 15.6 2.6 9.1 2.4 16.1 2.3 8.1 2.2 14.5 3 79 15 79 300 8.3 0 8.5 8.3 12/09/2005 09:50:00 9.5 1.9 14.1 3.8 9.5 2 14.1 4.2 8.5 2 14.5 3.4 78 17 94 300 8.3 0 8.5 8.3 12/09/2005 10:00:00 9.9 2.9 18.3 4.2 9.9 2.9 18.7 3.8 8.8 2.6 16.4 3.8 75 17 59 300 8.4 0 8.5 8.3 12/09/2005 10:10:00 9.6 1.7 14.9 4.6 9.7 1.7 14.9 4.9 8.6 1.6 12.2 4.6 77 13 56 300 8.4 0 8.8 8.3 12/09/2005 10:20:00 9.5 2 14.9 4.2 9.6 2.1 14.9 4.6 8.1 2.2 14.1 3.8 76 13 80 300 8.4 0 8.5 8.3 12/09/2005 10:30:00 8.9 1.9 13.7 4.2 8.9 1.9 13.3 4.2 7.7 1.9 15.6 4.2 76 15 71 300 8.4 0 8.5 8.3 12/09/2005 10:40:00 9 1.7 13.7 3.8 9.1 1.7 13.7 4.6 7.9 1.7 13.3 4.2 76 17 55 300 8.5 0 8.8 8.5 12/09/2005 10:50:00 9.8 2.5 16.1 4.6 9.9 2.6 16.4 3.8 8.9 2.3 14.9 3.8 75 16 90 300 8.8 0 9 8.5 12/09/2005 11:00:00 10.3 2 15.3 5.3 10.5 2.1 15.6 4.6 8.8 2 14.9 3.8 76 13 67 300 9 0 9 9 12/09/2005 11:10:00 9 1.8 13.7 3 9.1 1.8 13.7 3 7.6 1.8 13.3 3.4 73 14 83 300 8.9 0 9 8.8 12/09/2005 11:20:00 8.4 2 13 4.2 8.5 2 13 3.8 7.3 2.1 13.3 3 76 17 62 300 8.9 0 9 8.8 12/09/2005 11:30:00 9.6 2.3 16.4 4.2 9.7 2.3 16.8 4.9 8.5 2.2 14.1 4.2 79 14 81 300 9 0 9 8.8 12/09/2005 11:40:00 9.8 2 14.9 4.6 9.9 2.1 14.9 4.2 8.3 1.9 14.5 4.6 72 14 88 300 8.9 0 9 8.8 12/09/2005 11:50:00 11 2.3 18.7 4.2 11.1 2.3 18.3 4.9 9.5 2.3 17.9 3.8 76 16 72 300 8.9 0 9 8.8 12/09/2005 12:00:00 11.1 1.8 16.1 6.8 11.3 1.9 16.4 6.1 9.9 1.9 14.9 5.3 78 13 87 300 8.9 0 9 8.8 12/09/2005 12:10:00 9.7 2.1 14.9 3.8 9.8 2.2 14.9 4.2 8.6 2.1 14.9 4.9 77 15 80 300 8.6 0 8.8 8.5 12/09/2005 12:20:00 9.6 1.7 14.1 3 9.7 1.7 14.1 3.4 8.8 1.7 14.5 4.6 75 13 76 300 8.3 0 8.5 8.3 12/09/2005 12:30:00 10.1 1.9 14.9 4.9 10.3 2 16.1 4.9 8.6 1.9 13.7 4.2 73 12 91 300 8.1 0 8.3 8.3 12/09/2005 12:40:00 9.4 1.8 13.7 5.3 9.6 1.8 13.7 6.1 8.5 1.7 12.6 3.8 75 12 95 300 8.1 0 8.3 8.3 12/09/2005 12:50:00 9.7 2.2 14.5 3.4 9.7 2.3 14.5 3 8.8 2.2 14.5 3.4 78 13 81 300 8.1 0 8.3 8 12/09/2005 13:00:00 9.3 1.6 14.9 4.9 9.4 1.7 14.5 5.7 8.1 2 13.7 3.4 77 14 75 300 8 0 8.3 7.8 12/09/2005 13:10:00 8.7 1.8 14.9 4.6 8.9 1.8 14.5 4.9 7.6 1.8 12.6 3.4 77 15 80 300 8 0 8 7.8 12/09/2005 13:20:00 8.3 1.5 12.6 3 8.4 1.6 12.2 3 7.4 1.7 11.8 2.6 79 15 78 300 8 0 8.3 7.8 12/09/2005 13:30:00 7.3 1.7 11.5 3.8 7.3 1.7 12.2 3 6.7 1.7 11.5 3 74 17 78 300 7.8 0 8 7.8 12/09/2005 13:40:00 7.9 1.6 11.5 3.8 7.9 1.7 11.5 3 7 1.7 11.5 3.4 70 15 63 300 7.8 0 7.8 7.5 12/09/2005 13:50:00 6.5 1.5 9.9 3 6.6 1.6 10.3 2.6 5.3 1.3 8.4 2.3 65 17 77 300 7.6 0 7.8 7.5 12/09/2005 14:00:00 6.5 1.2 9.5 3.4 6.4 1.3 9.5 2.3 5.1 1.4 9.1 1.9 53 15 73 300 7.5 0 7.5 7.3 12/09/2005 14:10:00 6.5 1.3 9.5 3.4 6.4 1.5 9.5 2.6 4.8 1.7 9.1 1.9 44 14 47 300 7.3 0 7.5 7.3 12/09/2005 14:20:00 7.3 1.2 10.3 3.8 7.2 1.3 9.9 3.4 5.3 1.4 9.1 1.9 46 11 49 300 7.3 0 7.5 7.3 12/09/2005 14:30:00 7 1 9.1 3.4 6.8 1.1 9.1 3.4 4.9 1.2 8 2.3 47 11 51 300 7.3 0 7.5 7.3 12/09/2005 14:40:00 7.3 1 9.9 4.9 7.1 1.1 9.9 4.2 5 1.2 9.5 2.3 45 10 54 300 7.3 0 7.3 7.3 12/09/2005 14:50:00 6.6 1 8.8 4.2 6.4 1.2 8.8 3 4.8 1.3 8 1.9 44 10 49 300 7.2 0 7.3 7 12/09/2005 15:00:00 5.4 1.1 8.4 2.3 5.3 1.2 8.4 2.3 3.9 1 6.5 1.5 48 13 46 300 7.3 0 7.3 7.3 12/09/2005 15:10:00 6.1 1 8 3.4 5.8 1 7.6 3 4.5 1 7.2 2.3 43 8 28 300 7.2 0 7.3 7.3 12/09/2005 15:20:00 7.1 0.7 9.5 4.9 7.1 0.7 9.5 4.6 5.2 1 7.6 2.3 47 6 57 300 7.1 0 7.3 7 12/09/2005 15:30:00 7 0.7 8.4 4.9 6.6 0.9 8.4 4.2 4.8 1 7.6 1.9 40 9 40 300 7 0 7.3 7 12/09/2005 15:40:00 6.3 1.1 8.8 2.3 5.8 1.1 8.4 1.9 4.5 1 7.2 1.9 36 10 34 300 7.1 0 7.3 7 12/09/2005 15:50:00 6.4 0.7 8.4 3.8 5.4 0.8 7.6 2.6 4.4 0.8 6.5 2.3 27 8 38 300 7.1 0 7.3 7 12/09/2005 16:00:00 6.8 0.9 9.1 3.8 6 1 8.8 3.4 4.7 1 8 2.3 31 9 36 300 7.1 0 7.3 7 12/09/2005 16:10:00 6.2 1.2 9.1 3.4 5.9 1.1 8.4 3 4.6 1.2 6.8 1.9 41 13 24 300 7.1 0 7.3 7 12/09/2005 16:20:00 6.6 1.5 9.9 2.6 6.3 1.5 9.9 2.3 4.8 1.5 9.1 1.1 44 13 57 300 7.1 0 7.3 7 12/09/2005 16:30:00 6.1 0.8 8 3.8 5.9 0.9 8 3.8 4.5 1.1 8 2.3 44 11 48 300 7.2 0 7.3 7.3 12/09/2005 16:40:00 5.5 0.9 7.2 3 5.2 1 7.2 2.6 4.1 1 7.2 2.3 42 9 45 300 7.1 0.1 7.3 6.7 12/09/2005 16:50:00 6.1 0.8 8 3.4 5.8 0.9 8 3.4 4.4 1 7.2 1.5 42 8 45 300 6.7 0 6.7 6.7 12/09/2005 17:00:00 5.8 0.7 7.2 3.8 5.4 0.8 7.6 3 4.1 0.8 6.8 2.3 38 8 35 300 6.7 0 7 6.7 12/09/2005 17:10:00 6.1 0.7 8 4.2 5.6 0.8 7.6 3.4 4.6 0.9 6.8 2.3 37 8 25 300 6.8 0 7 6.7 12/09/2005 17:20:00 6.3 0.8 8 4.2 6 0.9 8 3.8 4.3 0.9 6.8 2.3 41 9 39 300 6.7 0 7 6.7 12/09/2005 17:30:00 6.1 0.9 8.4 3.4 5.7 1 8.4 3 4.3 1.1 7.2 1.5 39 10 33 300 7 0 7.3 7 12/09/2005 17:40:00 6 0.8 8 3.4 5.6 1 7.6 3 4.5 1 7.6 2.3 37 10 42 300 7.1 0 7.3 7 12/09/2005 17:50:00 6.1 1.2 9.1 1.9 5.6 1.3 9.1 1.9 4.4 1.2 8 1.9 35 11 22 300 7.2 0 7.3 7 12/09/2005 18:00:00 6.5 1.3 9.5 3 6.1 1.3 9.1 3 5.1 1.3 8.4 2.6 40 12 32 300 7.4 0 7.5 7.3 12/09/2005 18:10:00 7.3 1.4 11.1 3.8 7.1 1.5 11.5 3 5.8 1.5 9.5 2.6 44 12 48 300 7.5 0 7.5 7.3 12/09/2005 18:20:00 6.3 1.1 8.8 3 6.1 1.1 8.8 3 4.6 1.2 7.6 1.9 45 11 37 300 7.6 0 7.8 7.5 12/09/2005 18:30:00 4.8 1 8 1.9 4.8 1 8.4 1.9 4 1.1 7.2 1.9 62 15 53 300 7.4 0 7.5 7.3 12/09/2005 18:40:00 4.9 1 7.2 2.3 4.9 1.1 7.6 2.6 3.8 1.1 6.1 1.1 58 14 75 300 6.9 0 7.3 6.7 12/09/2005 18:50:00 5.2 1 7.2 3 5.2 1 7.6 2.6 3.8 1.1 6.8 1.5 56 13 54 300 6.6 0.1 6.7 6.2 12/09/2005 19:00:00 5.2 1.2 7.6 1.9 5.1 1.3 7.6 1.9 3.9 1.3 7.6 1.1 55 12 55 300 6.2 0 6.5 6.2 12/09/2005 19:10:00 4.6 1 6.5 1.9 4.6 1 6.5 1.5 3.6 0.9 6.8 1.5 54 13 34 300 6.2 0 6.5 6.2 12/09/2005 19:20:00 3.9 0.9 6.1 1.5 3.9 1 6.1 1.5 3.1 0.8 5.3 1.1 60 12 57 300 6.2 0 6.2 6 12/09/2005 19:30:00 3.4 0.7 4.9 1.5 3.4 0.7 4.9 0.7 2.7 0.7 4.2 1.1 59 13 39 300 6.1 0 6.2 6 12/09/2005 19:40:00 4.2 0.6 5.3 2.3 4.1 0.6 5.7 2.3 3.1 0.8 5.3 0.7 51 9 61 300 5.9 0 6 6 12/09/2005 19:50:00 3.9 0.8 6.1 1.9 3.8 0.8 6.5 1.5 2.7 0.8 4.9 0.7 56 13 50 300 6 0 6 6 12/09/2005 20:00:00 3.3 0.7 5.3 1.9 3.2 0.8 5.3 1.1 2.6 0.6 4.6 1.1 57 12 67 300 5.7 0 6 5.7 12/09/2005 20:10:00 3 0.7 4.9 1.1 2.9 0.8 4.9 0.7 2.1 0.7 4.2 0.4 51 13 40 300 5.5 0 5.7 5.5 12/09/2005 20:20:00 3.8 0.7 5.7 1.9 3.8 0.7 5.7 1.9 2.7 0.8 4.9 0.7 54 11 57 300 5.4 0 5.7 5.5 12/09/2005 20:30:00 2.7 0.8 4.6 0.7 2.5 0.9 4.6 0.7 2 0.7 3.8 0.7 60 14 62 300 5.2 0 5.5 5 12/09/2005 20:40:00 2.5 0.6 4.2 0.7 2.3 0.8 4.2 0.4 1.7 0.7 3.4 0.4 52 15 56 300 5 0 5 4.8 12/09/2005 20:50:00 2 0.9 3.8 0.4 1.8 1 3.8 0.4 1.7 0.8 3.8 0.4 91 29 81 300 4.5 0.2 5 3.8 12/09/2005 21:00:00 1.3 0.3 1.9 0.4 1 0.4 1.9 0.4 1.5 0.2 1.9 0.7 165 14 165 300 3.1 0.3 4 2.8 12/09/2005 21:10:00 0.7 0.4 1.5 0.4 0.5 0.3 1.5 0.4 1 0.5 1.9 0.4 218 11 181 300 2.7 0 2.8 2.6 12/09/2005 21:20:00 0.4 0.1 0.7 0.4 0.4 0 0.4 0.4 0.4 0.1 0.7 0.4 217 4 221 300 2.6 0 2.8 2.6 12/09/2005 21:30:00 0.4 0 0.7 0.4 0.4 0 0.4 0.4 0.4 0.1 0.7 0.4 261 94 155 300 2.8 0 3 2.6 12/09/2005 21:40:00 0.9 0.4 1.9 0.4 0.6 0.3 1.5 0.4 0.6 0.2 1.1 0.4 59 2 61 300 3.2 0 3.5 2.8 12/09/2005 21:50:00 1 0.5 2.3 0.4 0.8 0.4 1.9 0.4 1.1 0.5 1.9 0.4 86 19 104 300 3.1 0.2 3.5 2.8 12/09/2005 22:00:00 1 0.5 1.9 0.4 0.7 0.4 1.5 0.4 1.2 0.3 1.9 0.7 144 15 109 300 2.7 0 2.8 2.6 12/09/2005 22:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.5 0.2 1.1 0.4 153 0 300 300 2.5 0 2.8 2.3 12/09/2005 22:20:00 0.4 0.2 1.1 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 133 35 72 300 2.4 0 2.6 2.3 12/09/2005 22:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 72 0 300 300 2.3 0 2.6 2.3 12/09/2005 22:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 72 0 300 300 2 0 2.3 1.8 12/09/2005 22:50:00 0.4 0.1 0.7 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 114 17 121 300 1.8 0 2.1 1.8 12/09/2005 23:00:00 0.4 0.1 0.7 0.4 0.4 0 0.4 0.4 0.5 0.2 1.1 0.4 121 0 121 300 1.5 0.1 1.8 1.4 12/09/2005 23:10:00 0.5 0.2 1.1 0.4 0.4 0.1 1.1 0.4 0.5 0.2 1.1 0.4 180 20 182 300 1.4 0 1.6 1.4 12/09/2005 23:20:00 0.5 0.2 1.1 0.4 0.4 0 0.4 0.4 0.4 0.1 0.7 0.4 217 14 224 300 1.2 0 1.6 1.1 12/09/2005 23:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 224 0 300 300 1.1 0 1.4 0.9 12/09/2005 23:40:00 0.5 0.3 1.5 0.4 0.4 0.2 1.1 0.4 0.5 0.3 1.1 0.4 243 94 104 300 0.9 0 0.9 0.7 12/09/2005 23:50:00 1.4 0.3 1.9 0.4 1 0.3 1.5 0.4 0.9 0.2 1.1 0.4 100 5 96 300 0.8 0 0.9 0.7 12/10/2005 00:00:00 1.2 0.3 2.3 0.4 1 0.4 1.9 0.4 0.7 0.4 1.9 0.4 136 38 190 300 0.7 0 1.4 0.7 12/10/2005 00:10:00 1.3 0.4 2.3 0.4 1.4 0.4 2.3 0.7 1.3 0.4 2.3 0.4 202 5 193 300 1.1 0 1.4 0.9 12/10/2005 00:20:00 0.5 0.2 1.1 0.4 0.4 0.2 1.1 0.4 0.5 0.2 1.1 0.4 206 0 206 300 0.9 0 1.4 0.9 12/10/2005 00:30:00 0.4 0.1 1.1 0.4 0.4 0 0.7 0.4 0.4 0.1 0.7 0.4 245 28 264 300 0.9 0 1.1 0.9 12/10/2005 00:40:00 0.9 0.5 1.9 0.4 0.6 0.4 1.5 0.4 1 0.2 1.5 0.4 294 20 306 300 1.1 0 1.4 0.9 12/10/2005 00:50:00 2 0.3 2.6 1.5 1.7 0.4 2.3 1.1 1.8 0.4 2.6 1.1 329 11 341 300 1.1 0 1.4 0.9 12/10/2005 01:00:00 1.6 0.2 2.3 1.1 1.3 0.3 2.3 0.4 1.7 0.4 2.6 0.7 0 14 343 300 1 0 1.4 0.9 12/10/2005 01:10:00 1.6 0.2 1.9 1.1 1.3 0.2 1.9 0.7 1.4 0.2 1.9 0.7 44 10 43 300 1.2 0 1.4 1.4 12/10/2005 01:20:00 1.7 0.3 2.3 1.1 1.4 0.3 2.3 0.7 1.4 0.3 1.9 0.7 63 5 63 300 1 0.1 1.4 0.7 12/10/2005 01:30:00 1.2 0.2 1.5 0.7 0.9 0.2 1.5 0.4 1 0.2 1.5 0.7 67 0 68 300 0.7 0 0.9 0.7 12/10/2005 01:40:00 1.5 0.4 1.9 0.7 1.2 0.4 1.9 0.4 1.1 0.3 1.9 0.4 64 4 67 300 1 0.2 1.4 0.7 12/10/2005 01:50:00 1.8 0.2 2.3 1.5 1.6 0.2 1.9 1.1 1.7 0.2 1.9 1.1 54 3 58 300 1.3 0 1.6 1.4 12/10/2005 02:00:00 1.8 0.2 2.3 1.1 1.5 0.2 1.9 1.1 1.3 0.3 1.9 0.4 54 1 58 300 1.5 0 1.6 1.4 12/10/2005 02:10:00 1.8 0.2 2.3 1.5 1.5 0.3 2.3 0.7 1.3 0.3 1.9 0.7 43 6 36 300 1.5 0 1.6 1.4 12/10/2005 02:20:00 1.5 0.2 2.3 1.1 1.1 0.3 1.9 0.4 1.1 0.3 1.5 0.4 43 7 61 300 1.6 0.3 2.3 1.4 12/10/2005 02:30:00 0.7 0.3 1.5 0.4 0.4 0.1 0.7 0.4 0.6 0.2 1.1 0.4 34 0 34 300 1.8 0 2.3 1.8 12/10/2005 02:40:00 1.5 0.4 1.9 0.7 1.1 0.5 1.9 0.4 1.3 0.4 1.9 0.7 36 4 34 300 1.7 0 1.8 1.6 12/10/2005 02:50:00 2.6 1.2 4.2 0.4 2.5 1.2 4.2 0.4 2.7 1.4 4.2 0.4 283 82 220 300 1.6 0 1.8 1.6 12/10/2005 03:00:00 3.8 0.5 4.9 3 3.6 0.5 4.6 2.6 3 0.7 4.6 1.9 231 4 222 300 1.8 0 1.8 1.6 12/10/2005 03:10:00 2.9 0.3 3.4 2.3 2.7 0.3 3.4 1.9 2.4 0.4 3.4 1.9 246 10 232 300 1.8 0 1.8 1.8 12/10/2005 03:20:00 2.8 0.4 3.8 1.9 2.7 0.4 3.4 1.9 2.3 0.3 3 1.5 273 9 256 300 2.1 0.1 2.6 1.8 12/10/2005 03:30:00 2.3 0.4 3 1.5 2.1 0.4 3 1.1 2 0.3 2.6 1.5 296 5 289 300 2.6 0 2.8 2.3 12/10/2005 03:40:00 1.3 0.4 2.3 0.4 1 0.5 1.9 0.4 1.5 0.3 2.3 0.7 286 13 299 300 2.3 0 2.6 2.1 12/10/2005 03:50:00 0.8 0.3 1.1 0.4 0.4 0.2 1.1 0.4 1.2 0.2 1.5 0.7 283 10 267 300 2.3 0 2.6 2.3 12/10/2005 04:00:00 1.5 0.5 2.3 0.4 1.2 0.6 2.3 0.4 1.8 0.4 2.3 1.1 311 5 315 300 2.6 0 2.8 2.3 12/10/2005 04:10:00 2 0.2 2.3 1.5 1.8 0.2 2.3 1.5 2 0.2 2.6 1.5 315 2 316 300 2.7 0 2.8 2.6 12/10/2005 04:20:00 2 0.2 2.6 1.5 1.7 0.3 2.3 1.1 1.8 0.2 2.3 1.5 315 2 315 300 2.6 0 2.8 2.6 12/10/2005 04:30:00 2.1 0.2 2.6 1.5 1.9 0.2 2.3 1.5 1.6 0.3 2.3 0.4 306 6 308 300 2.7 0 2.8 2.6 12/10/2005 04:40:00 1.8 0.4 2.6 0.7 1.5 0.5 2.6 0.7 0.7 0.4 1.9 0.4 307 5 299 300 2.5 0.1 2.8 2.3 12/10/2005 04:50:00 2 0.5 3.4 0.7 1.6 0.5 3.4 0.4 1.3 0.4 2.3 0.4 289 5 292 300 2.3 0 2.3 2.3 12/10/2005 05:00:00 2.3 0.4 3.4 1.1 2.1 0.5 3 0.7 1.6 0.6 2.6 0.4 296 7 281 300 2.4 0 2.6 2.3 12/10/2005 05:10:00 1.9 0.5 3 0.7 1.6 0.6 3 0.4 1 0.4 1.9 0.4 299 6 297 300 2.2 0 2.6 2.1 12/10/2005 05:20:00 2.3 0.5 3.4 0.7 2 0.6 3.8 0.4 1.5 0.5 2.6 0.4 309 6 317 300 2.4 0 2.6 2.3 12/10/2005 05:30:00 1.9 0.5 3 0.7 1.6 0.6 2.6 0.4 1 0.5 1.9 0.4 319 8 306 300 2.3 0 2.6 2.3 12/10/2005 05:40:00 2.3 0.4 3 1.5 2.2 0.4 3 1.1 1.7 0.4 2.6 0.4 320 5 320 300 2.3 0 2.6 2.3 12/10/2005 05:50:00 2.4 0.4 3 1.5 2.3 0.4 3 1.1 1.9 0.3 2.6 1.1 328 7 333 300 2.7 0.1 3.3 2.3 12/10/2005 06:00:00 1.9 0.4 3 0.7 1.7 0.5 2.6 0.7 1.5 0.3 2.3 0.7 345 11 332 300 3.7 0.3 4 3 12/10/2005 06:10:00 1.6 0.4 2.6 0.4 1.2 0.5 2.3 0.4 1.2 0.5 2.6 0.4 352 8 352 300 4 0 4.3 3.8 12/10/2005 06:20:00 0.9 0.5 1.9 0.4 0.6 0.4 1.5 0.4 0.7 0.4 1.9 0.4 0 1 357 300 3.6 0.1 4 3.5 12/10/2005 06:30:00 1 0.5 1.9 0.4 0.7 0.4 1.9 0.4 0.7 0.4 1.9 0.4 358 6 3 300 3.3 0 3.5 3.3 12/10/2005 06:40:00 1.2 0.2 1.9 0.7 0.6 0.3 1.5 0.4 0.9 0.4 1.5 0.4 12 12 27 300 2.9 0 3.3 2.8 12/10/2005 06:50:00 1 0.3 1.9 0.4 0.5 0.2 1.1 0.4 1.1 0.3 1.9 0.4 29 2 28 300 2.9 0 2.8 2.8 12/10/2005 07:00:00 0.8 0.3 1.5 0.4 0.4 0.2 1.1 0.4 1.1 0.4 1.9 0.4 42 10 50 300 2.9 0 2.8 2.8 12/10/2005 07:10:00 1.7 0.2 1.9 1.1 1.4 0.2 1.9 1.1 1.6 0.2 1.9 1.1 61 8 54 300 2.9 0 2.8 2.8 12/10/2005 07:20:00 1.7 0.2 2.3 1.5 1.4 0.2 1.9 1.1 1.7 0.2 1.9 1.1 78 0 78 300 2.9 0 2.8 2.8 12/10/2005 07:30:00 1.7 0.2 1.9 1.5 1.4 0.2 1.5 1.1 1.5 0.2 1.9 1.1 78 0 79 300 2.9 0 2.8 2.8 12/10/2005 07:40:00 1.6 0.2 1.9 1.5 1.3 0.2 1.9 1.1 1.3 0.2 1.9 0.7 75 3 79 300 2.8 0 2.8 2.8 12/10/2005 07:50:00 1.5 0.2 1.9 1.1 1.1 0.2 1.5 0.7 1.1 0.2 1.5 0.7 75 4 72 300 2.7 0 2.8 2.6 12/10/2005 08:00:00 1.7 0.3 2.3 1.1 1.4 0.4 1.9 0.7 1.4 0.3 1.9 0.7 74 7 66 300 2.7 0 2.8 2.6 12/10/2005 08:10:00 2.1 0.2 2.6 1.9 1.9 0.1 2.3 1.5 1.8 0.2 2.3 1.5 57 1 57 300 2.4 0 2.8 2.3 12/10/2005 08:20:00 2 0.2 2.3 1.5 1.8 0.2 2.3 1.5 1.7 0.2 1.9 1.1 51 2 56 300 2.7 0 2.8 2.6 12/10/2005 08:30:00 2 0.2 2.3 1.9 1.6 0.2 1.9 1.1 1.7 0.2 1.9 1.1 40 6 49 300 2.9 0 2.8 2.8 12/10/2005 08:40:00 1.9 0.2 2.3 1.5 1.5 0.2 2.3 1.1 1.3 0.3 1.9 0.7 19 9 30 300 2.9 0 3 2.8 12/10/2005 08:50:00 1.8 0.2 2.3 1.1 1.5 0.3 2.3 0.7 0.9 0.3 1.5 0.4 4 3 359 300 2.9 0 2.8 2.8 12/10/2005 09:00:00 1.6 0.2 2.3 1.1 1.3 0.3 2.3 0.4 0.7 0.2 1.5 0.4 9 2 11 300 2.8 0 2.8 2.8 12/10/2005 09:10:00 1.4 0.3 1.9 0.7 1 0.4 1.9 0.4 0.6 0.2 1.5 0.4 6 4 8 300 2.9 0 2.8 2.8 12/10/2005 09:20:00 1.9 0.3 2.6 1.1 1.6 0.4 2.3 0.4 0.9 0.4 1.9 0.4 2 4 354 300 2.9 0 2.8 2.8 12/10/2005 09:30:00 1.7 0.3 2.3 1.1 1.2 0.5 2.3 0.4 1.1 0.3 1.9 0.4 9 7 6 300 2.8 0 2.8 2.8 12/10/2005 09:40:00 2 0.3 3 1.1 1.6 0.4 2.6 0.7 1.3 0.3 2.3 0.7 16 5 19 300 2.7 0 2.8 2.6 12/10/2005 09:50:00 2.5 0.4 3 1.9 2.2 0.4 3 1.1 1.7 0.4 2.6 0.7 13 6 12 300 2.9 0 3.3 2.8 12/10/2005 10:00:00 2.2 0.4 3 1.1 1.9 0.5 3 0.7 1.4 0.4 2.6 0.4 14 5 19 300 3 0 3.3 3 12/10/2005 10:10:00 1.9 0.3 2.3 1.5 1.5 0.3 2.3 0.4 1.1 0.3 2.3 0.7 18 4 16 300 3 0 3.3 2.8 12/10/2005 10:20:00 1.8 0.3 2.3 1.1 1.3 0.3 2.3 0.4 1.1 0.3 1.9 0.4 26 5 21 300 2.9 0 3 2.8 12/10/2005 10:30:00 1.8 0.2 2.3 1.1 1.4 0.3 1.9 0.4 1.2 0.3 1.9 0.7 30 3 28 300 2.9 0 3 2.8 12/10/2005 10:40:00 1.9 0.2 2.6 1.5 1.6 0.3 2.3 0.7 1.3 0.3 2.3 0.4 34 5 34 300 2.9 0 3 2.8 12/10/2005 10:50:00 2.1 0.3 3 1.5 1.8 0.4 2.6 0.7 1.4 0.3 2.3 0.7 33 4 32 300 2.9 0 2.8 2.8 12/10/2005 11:00:00 2.1 0.3 2.6 1.1 1.7 0.4 2.6 0.7 1.3 0.3 2.3 0.7 32 4 33 300 2.9 0 2.8 2.8 12/10/2005 11:10:00 1.9 0.3 2.6 1.1 1.5 0.3 2.3 0.7 1.2 0.3 2.3 0.4 33 5 30 300 2.9 0 2.8 2.8 12/10/2005 11:20:00 2.2 0.3 3 1.5 1.9 0.4 3 0.7 1.6 0.4 2.6 0.7 37 4 40 300 2.9 0 3 2.8 12/10/2005 11:30:00 2.3 0.4 3.4 1.1 2 0.5 3.4 0.7 1.6 0.4 2.6 0.4 37 7 33 300 2.9 0 3 2.8 12/10/2005 11:40:00 2.3 0.3 3 1.5 2.2 0.3 3 1.5 1.9 0.4 2.6 1.1 46 5 41 300 2.9 0 2.8 2.8 12/10/2005 11:50:00 2.7 0.3 3.4 1.9 2.6 0.4 3.4 1.5 1.9 0.5 3 0.4 46 5 56 300 2.9 0 3 2.8 12/10/2005 12:00:00 2.9 0.4 3.8 1.5 2.9 0.4 3.8 1.5 2.1 0.5 3.4 0.7 47 6 49 300 3 0 3.3 2.8 12/10/2005 12:10:00 2.9 0.4 4.2 1.9 2.8 0.4 3.8 1.5 2.2 0.5 3.4 1.1 47 6 50 300 3.2 0 3.3 3 12/10/2005 12:20:00 2.3 0.4 3 1.5 2.2 0.4 3 1.1 1.9 0.5 3 0.4 37 7 43 300 3.2 0 3.3 3.3 12/10/2005 12:30:00 3.1 0.4 3.8 1.9 3 0.4 3.8 1.5 2.3 0.5 4.2 1.1 47 5 48 300 3.2 0 3.3 3.3 12/10/2005 12:40:00 3.1 0.6 4.2 1.1 2.9 0.6 4.2 0.7 2 0.6 3.8 0.4 47 10 43 300 3.2 0 3.3 3.3 12/10/2005 12:50:00 2.6 0.5 3.8 1.1 2.4 0.5 3.8 0.7 1.8 0.6 3.4 0.4 45 9 31 300 3.2 0 3.3 3.3 12/10/2005 13:00:00 2.3 0.6 3.4 0.4 2.1 0.6 3.4 0.4 1.6 0.6 3 0.4 43 10 36 300 3.2 0 3.3 3.3 12/10/2005 13:10:00 2.6 0.4 3.8 1.5 2.4 0.5 3.4 1.1 2.1 0.5 3.4 0.7 43 8 36 300 3.2 0 3.3 3.3 12/10/2005 13:20:00 3.2 0.4 3.8 1.9 3.1 0.4 3.8 1.5 2.3 0.6 3.8 1.1 47 5 47 300 3.2 0 3.3 3.3 12/10/2005 13:30:00 2.8 0.4 3.8 1.5 2.6 0.5 3.8 1.5 2 0.5 3.4 0.7 44 7 49 300 3.2 0 3.5 3.3 12/10/2005 13:40:00 2.6 0.4 3.4 1.5 2.4 0.4 3.4 1.1 1.9 0.5 3 0.7 42 7 40 300 3.3 0 3.5 3.3 12/10/2005 13:50:00 2.6 0.5 3.8 1.1 2.5 0.6 3.8 0.7 1.9 0.6 3 0.4 47 8 43 300 3.4 0 3.5 3.3 12/10/2005 14:00:00 2.4 0.4 3.4 1.1 2.3 0.5 3.4 0.4 1.8 0.5 3.4 0.7 43 7 59 300 3.4 0 3.5 3.3 12/10/2005 14:10:00 2.8 0.4 3.8 1.9 2.6 0.4 3.8 1.5 1.9 0.5 3 0.7 43 7 40 300 3.4 0 3.5 3.5 12/10/2005 14:20:00 2.9 0.5 4.2 1.9 2.7 0.6 4.2 1.5 2 0.6 3.8 0.4 40 10 39 300 3.4 0 3.5 3.5 12/10/2005 14:30:00 2.7 0.6 4.2 1.5 2.5 0.7 4.2 0.7 1.9 0.6 3.4 0.4 39 11 51 300 3.5 0 3.5 3.5 12/10/2005 14:40:00 2.6 0.5 4.2 1.5 2.3 0.6 3.8 0.7 1.7 0.6 3 0.4 37 11 49 300 3.5 0 3.5 3.5 12/10/2005 14:50:00 2.2 0.5 3.4 0.7 1.9 0.6 3 0.4 1.4 0.5 2.6 0.4 39 11 38 300 3.4 0 3.5 3.3 12/10/2005 15:00:00 2.3 0.9 4.2 0.4 1.9 0.8 3.8 0.4 1.4 0.7 3 0.4 35 12 36 300 3.4 0 3.5 3.3 12/10/2005 15:10:00 3.8 0.5 4.9 2.6 3.4 0.5 4.9 1.9 2.5 0.5 4.2 1.5 36 10 28 300 3.4 0 3.5 3.3 12/10/2005 15:20:00 3.4 0.5 4.9 2.3 3 0.6 4.6 1.5 2.4 0.6 3.8 0.7 37 7 37 300 3.5 0 3.5 3.5 12/10/2005 15:30:00 3.7 0.6 5.3 2.3 3.3 0.6 4.9 1.1 2.6 0.6 4.6 1.1 37 8 30 300 3.4 0 3.5 3.3 12/10/2005 15:40:00 3.7 0.8 5.7 1.9 3 0.8 4.9 1.1 2.6 0.8 5.3 1.1 28 11 18 300 3.3 0 3.5 3.3 12/10/2005 15:50:00 3.7 0.6 4.9 1.5 3.2 0.7 4.9 1.1 2.7 0.6 4.6 1.1 18 10 17 300 3.3 0 3.5 3.3 12/10/2005 16:00:00 2.8 1.2 5.3 0.4 2.5 1.3 4.9 0.4 1.8 0.9 4.2 0.4 22 22 13 300 3.2 0.1 3.5 2.8 12/10/2005 16:10:00 1.3 0.7 3 0.4 1 0.7 2.6 0.4 0.9 0.6 2.6 0.4 39 26 57 300 3 0 3.3 2.8 12/10/2005 16:20:00 1.9 0.7 3.8 0.4 1.4 0.7 3.4 0.4 1.5 0.6 3 0.4 31 16 8 300 2.9 0 3.3 2.8 12/10/2005 16:30:00 2.8 0.6 4.2 1.5 2.3 0.7 3.8 0.7 2.1 0.5 3.4 1.1 37 13 25 300 3 0 3.3 3 12/10/2005 16:40:00 2.4 0.7 3.8 0.4 1.7 0.8 3.8 0.4 1.6 0.5 3 0.4 26 16 30 300 3.1 0 3.3 2.8 12/10/2005 16:50:00 2.1 0.6 4.2 0.4 1.6 0.7 3.8 0.4 1.6 0.5 2.6 0.4 29 14 36 300 3.3 0 3.5 3.3 12/10/2005 17:00:00 1.6 1.2 4.2 0.4 1.2 1 4.2 0.4 1.1 0.7 2.6 0.4 12 32 18 300 3.3 0 3.5 3.3 12/10/2005 17:10:00 1 0.7 2.6 0.4 0.7 0.6 2.6 0.4 0.9 0.6 2.3 0.4 33 19 22 300 3.2 0 3.5 3 12/10/2005 17:20:00 3 0.9 5.7 0.4 2.4 0.9 5.3 0.4 1.8 0.8 4.6 0.4 35 17 34 300 2.9 0 3.3 2.6 12/10/2005 17:30:00 4.1 0.9 6.1 1.5 3.4 0.9 5.7 0.7 2.7 1 4.9 0.4 26 12 22 300 3 0.1 3.3 2.8 12/10/2005 17:40:00 4.7 0.8 6.5 2.6 4.3 1 6.8 1.9 3.3 0.8 6.1 1.5 18 10 21 300 3.6 0.1 3.8 3.3 12/10/2005 17:50:00 5.6 1 7.6 2.3 5.3 1.2 7.6 1.5 4 1.1 6.5 1.5 13 11 0 300 3.7 0 4 3.5 12/10/2005 18:00:00 4.9 1.1 7.6 1.9 4.7 1.1 7.2 1.9 3.9 1 6.5 1.9 8 11 21 300 4 0 4.3 3.8 12/10/2005 18:10:00 4 0.8 6.1 2.3 3.8 1 6.1 1.1 3.3 0.9 5.3 1.1 3 12 355 300 4 0 4.3 3.8 12/10/2005 18:20:00 3.3 0.7 5.3 1.5 2.9 0.8 4.9 0.7 2.4 0.6 4.6 0.7 15 13 27 300 3.8 0 3.8 3.5 12/10/2005 18:30:00 3.8 1 6.1 1.5 3.2 1 5.7 1.1 2.6 0.9 4.9 0.4 17 12 26 300 3.8 0 4 3.8 12/10/2005 18:40:00 4.8 0.7 6.5 3 3.8 0.7 6.5 2.3 3.2 0.7 5.7 1.5 26 8 22 300 4 0 4.3 3.8 12/10/2005 18:50:00 5 0.8 6.8 2.6 4.1 0.8 6.5 1.9 3.4 0.7 5.7 1.9 26 10 26 300 4.2 0 4.5 4 12/10/2005 19:00:00 5.1 1 7.6 2.3 4.2 0.9 7.6 1.5 3.2 0.9 6.5 0.7 22 12 2 300 4.3 0 4.5 4.3 12/10/2005 19:10:00 5.3 1.1 8 2.6 4.6 1.1 7.6 1.5 3.6 1.1 6.1 1.1 24 13 14 300 4.6 0 4.8 4.5 12/10/2005 19:20:00 5.6 1 7.6 3.4 4.9 1 7.2 2.6 4 1 6.8 1.9 23 12 22 300 5.1 0 5.2 4.8 12/10/2005 19:30:00 5.5 1 8 3 5.1 1.1 7.6 2.3 4.3 1 6.8 1.9 23 15 21 300 5.4 0.2 5.7 5 12/10/2005 19:40:00 4.8 1 8 1.9 4.2 1.1 7.6 1.1 3.4 1 6.1 1.5 23 15 37 300 5.2 0.1 5.7 5 12/10/2005 19:50:00 4.8 1.2 8.4 1.5 4.5 1.1 8.4 1.5 3.7 1.1 7.2 1.1 47 22 348 300 5.3 0 5.5 5 12/10/2005 20:00:00 5.2 1.2 8.4 2.3 4.8 1.3 8.4 1.5 3.7 1.2 7.2 1.1 47 17 62 300 5.4 0 5.7 5.2 12/10/2005 20:10:00 5.4 1.1 8.8 2.3 4.9 1.2 7.6 1.9 3.7 1 6.5 1.1 43 15 43 300 5.4 0 5.5 5.2 12/10/2005 20:20:00 5.1 1.1 7.6 1.9 4.8 1.1 7.6 1.5 3.6 1 6.5 1.1 44 15 52 300 5.4 0 5.5 5.2 12/10/2005 20:30:00 4.8 1.4 7.6 1.1 4.5 1.3 7.6 0.7 3.7 1.1 6.5 1.5 47 17 38 300 5.4 0 5.7 5.2 12/10/2005 20:40:00 4.5 0.7 6.5 2.3 4 0.8 6.1 1.9 3.2 0.9 5.7 1.5 34 13 32 300 5.1 0 5.2 5 12/10/2005 20:50:00 4.1 1.2 7.2 0.4 3.8 1.2 6.5 0.4 2.7 1.1 6.5 0.4 50 23 42 300 5.1 0 5.2 5 12/10/2005 21:00:00 5.6 1.6 11.1 1.5 5.5 1.7 12.2 1.1 4.6 1.5 9.9 1.1 67 20 71 300 5.7 0.3 6.2 5 12/10/2005 21:10:00 8.7 1.6 13 4.2 8.8 1.6 13.3 4.6 7.5 1.6 11.5 3.4 76 13 69 300 6.9 0.2 7.3 6.2 12/10/2005 21:20:00 5.1 1.2 8.4 1.9 5.1 1.3 8.8 1.9 4.4 1.2 8.8 1.9 65 15 83 300 6.6 0.2 7 6.2 12/10/2005 21:30:00 6.2 1.5 9.5 2.6 6.2 1.5 9.5 2.3 4.7 1.4 9.1 1.9 62 20 81 300 6.3 0.1 6.5 6.2 12/10/2005 21:40:00 6.6 1.1 9.9 3.8 6.4 1.2 9.9 3.4 4.7 1.4 9.5 1.9 47 11 47 300 5.8 0.2 6.2 5.5 12/10/2005 21:50:00 5.9 1 8 2.3 5.5 1 8 2.6 4 1.1 7.2 1.5 37 11 30 300 5.2 0.1 5.7 4.8 12/10/2005 22:00:00 5.4 1 8 1.9 5.1 1.2 8.4 1.9 3.8 1 6.5 1.5 42 13 72 300 4.9 0 5 4.8 12/10/2005 22:10:00 4.9 1 7.6 3 4.7 1.1 7.6 2.6 3.6 1.1 6.5 1.1 49 17 39 300 5.2 0 5.5 5 12/10/2005 22:20:00 5.1 1.1 7.6 2.6 5 1.1 8 2.6 3.7 1.2 7.2 0.4 54 13 57 300 5.4 0 5.5 5.2 12/10/2005 22:30:00 5.4 1.3 11.1 3 5.3 1.4 11.1 2.6 4.3 1.2 8.4 1.5 58 18 73 300 5.9 0.1 6.2 5.5 12/10/2005 22:40:00 5.3 1.1 7.6 1.9 5.1 1.3 8 1.1 3.9 1.1 6.8 1.1 44 15 56 300 6.1 0 6.2 6 12/10/2005 22:50:00 4.3 1 6.5 1.5 3.9 1 6.5 0.7 3.2 1 5.7 0.7 35 16 39 300 5.7 0.1 6 5.7 12/10/2005 23:00:00 4.1 0.7 6.5 2.3 3.7 0.7 5.3 1.5 3 0.7 5.3 1.5 40 15 65 300 5.6 0 5.7 5.5 12/10/2005 23:10:00 5.2 1 8 2.6 5 1.1 8.4 2.3 3.9 1.1 6.8 1.5 46 15 49 300 5.5 0 5.7 5.5 12/10/2005 23:20:00 5.9 1.5 9.5 1.5 5.7 1.6 9.5 1.1 4.4 1.4 8.8 1.5 47 17 52 300 5.8 0.1 6.2 5.5 12/10/2005 23:30:00 5.9 1.5 9.9 2.3 5.7 1.6 10.3 2.3 4.3 1.5 9.5 1.1 52 17 65 300 6.4 0.1 6.7 6 12/10/2005 23:40:00 5.3 1.5 10.3 1.1 5.2 1.5 9.5 1.1 4 1.5 9.1 0.7 56 22 108 300 6.1 0 6.5 6 12/10/2005 23:50:00 6.6 1.7 12.6 2.3 6.5 1.9 12.6 1.9 5.1 1.5 9.9 1.9 56 17 62 300 6.1 0 6.2 6 12/11/2005 00:00:00 6.3 1.7 11.8 2.3 6.3 1.8 11.8 2.3 4.9 1.7 9.1 1.5 58 20 85 300 6.2 0 6.5 6 12/11/2005 00:10:00 7.6 1.8 12.6 3.8 7.4 2 13 2.3 5.5 1.7 10.3 1.9 53 17 30 300 6.1 0 6.2 6 12/11/2005 00:20:00 7.2 1.3 10.7 1.9 6.9 1.4 10.7 2.3 5.1 1.5 8.4 1.1 43 14 27 300 5.7 0 6 5.5 12/11/2005 00:30:00 7.5 1.3 10.7 4.6 7.2 1.3 10.3 4.2 5.6 1.5 9.5 1.1 43 10 38 300 5.6 0 5.7 5.5 12/11/2005 00:40:00 7.7 1.3 11.1 4.2 7.4 1.5 10.7 3.8 5.3 1.6 9.9 1.5 44 12 40 300 5.6 0 5.7 5.5 12/11/2005 00:50:00 6.8 1.2 9.5 3.8 6.6 1.2 9.9 3.8 4.8 1.3 8 1.1 43 12 36 300 5.4 0 5.5 5.2 12/11/2005 01:00:00 7.4 1.1 10.3 4.6 7 1.2 9.9 3.8 5.3 1.2 8.8 2.3 40 12 45 300 5.3 0 5.5 5.2 12/11/2005 01:10:00 7.1 1.2 9.9 4.2 6.6 1.4 9.9 3.4 4.9 1.3 9.5 1.5 38 15 47 300 5.4 0 5.7 5.2 12/11/2005 01:20:00 7.6 1.2 12.2 4.2 7.3 1.4 12.2 3.8 5.5 1.7 9.9 1.9 42 12 56 300 5.6 0 5.7 5.5 12/11/2005 01:30:00 7.5 1.2 9.9 4.2 7.3 1.3 10.3 3.4 5.5 1.3 8.8 2.3 45 12 46 300 5.5 0 5.7 5.5 12/11/2005 01:40:00 7.3 1.1 9.5 3.8 7 1.2 9.1 3.4 5 1.3 8.4 1.9 44 12 65 300 5.5 0 5.7 5.5 12/11/2005 01:50:00 7.1 1 9.1 4.6 6.7 1 9.1 3.8 5.3 1.2 8.4 2.6 40 10 53 300 5.6 0 5.7 5.5 12/11/2005 02:00:00 7.2 1.4 10.7 3.8 6.4 1.4 10.3 3.4 4.9 1.3 9.1 1.9 31 12 20 300 5.7 0 5.7 5.7 12/11/2005 02:10:00 7.7 1.3 11.1 3.8 7 1.4 11.1 3 5.4 1.3 9.1 1.9 35 13 39 300 5.8 0 6 5.7 12/11/2005 02:20:00 7.3 1 9.5 4.6 6.5 1.1 9.5 3.8 5.2 1.2 8 1.9 32 11 32 300 5.8 0 6 5.7 12/11/2005 02:30:00 7.1 0.8 9.1 4.6 6.2 1 9.1 3.8 5.2 0.9 7.6 2.6 29 9 39 300 5.7 0 6 5.7 12/11/2005 02:40:00 7.5 1 10.3 4.9 6.5 1 9.9 3.8 5.1 1.1 8 1.9 27 9 32 300 5.6 0 5.7 5.5 12/11/2005 02:50:00 7.7 1 9.9 4.6 6.7 1.1 9.5 3.4 5.4 1.1 9.5 2.3 31 10 28 300 5.4 0 5.7 5.5 12/11/2005 03:00:00 7 1.3 9.9 4.6 6.4 1.3 9.9 3.4 4.9 1.1 8 2.3 38 12 24 300 5.6 0 5.7 5.5 12/11/2005 03:10:00 6.1 1.2 9.1 2.6 5.7 1.2 9.1 2.3 4.4 1.2 8 1.5 41 11 39 300 5.6 0 5.7 5.5 12/11/2005 03:20:00 6.6 1.2 9.1 3.4 6.3 1.2 9.1 2.3 4.5 1.2 8 1.9 43 13 36 300 5.6 0 5.7 5.5 12/11/2005 03:30:00 6.9 1.1 9.9 4.2 6.7 1.2 9.9 3.4 5.1 1.2 9.5 2.3 46 10 49 300 5.7 0 6 5.7 12/11/2005 03:40:00 7.4 1.2 11.1 4.2 7.3 1.4 11.1 2.6 5.4 1.5 9.5 1.9 50 13 59 300 5.8 0.1 6.2 5.7 12/11/2005 03:50:00 7.4 1.5 11.5 3.4 7 1.5 11.1 3 5.4 1.6 9.5 2.3 44 13 33 300 6.2 0 6.5 6 12/11/2005 04:00:00 7.6 1.4 10.7 3 7.2 1.6 10.7 2.6 5.5 1.5 9.5 1.9 41 11 42 300 6.8 0.1 7 6.5 12/11/2005 04:10:00 7.3 1.4 9.9 3.4 7 1.5 10.3 2.6 5.3 1.3 9.1 1.9 41 11 56 300 6.6 0 6.7 6.2 12/11/2005 04:20:00 7.9 1.1 10.7 4.2 7.4 1.3 11.1 3.8 6 1.3 9.1 3 39 11 60 300 6.7 0 7 6.5 12/11/2005 04:30:00 7.4 1.2 9.9 3.4 7.1 1.4 9.9 2.3 5.6 1.2 8.8 2.3 40 11 40 300 6.7 0 7 6.7 12/11/2005 04:40:00 6.9 1 9.1 4.2 6.5 1.2 9.5 3.4 5.2 1.2 8.4 2.3 41 10 36 300 6.7 0 7 6.7 12/11/2005 04:50:00 6.9 1.2 11.5 4.2 6.6 1.3 11.5 3.4 5.1 1.5 9.9 1.9 45 12 51 300 6.8 0 7 6.7 12/11/2005 05:00:00 6.4 1.2 9.9 3.4 6.1 1.3 9.9 3 4.9 1.2 8.8 1.9 42 12 39 300 6.9 0 7 6.7 12/11/2005 05:10:00 6.3 1.1 9.1 3.8 5.9 1.3 9.1 3 4.8 1.1 8 2.3 39 10 40 300 6.9 0 7 6.7 12/11/2005 05:20:00 7 1.2 9.5 3.8 6.4 1.3 9.5 3 5.2 1.3 8.8 2.3 38 11 31 300 6.9 0 7 7 12/11/2005 05:30:00 6.8 1.3 10.3 2.6 6.5 1.3 9.5 1.9 4.9 1.2 8.4 1.5 43 14 21 300 6.9 0 7 6.7 12/11/2005 05:40:00 6.9 1.1 9.9 4.6 6.3 1.2 9.9 3 5.1 1.1 8.8 2.3 34 11 34 300 6.7 0 7 6.7 12/11/2005 05:50:00 7.1 1.3 10.7 3.4 6.6 1.4 10.3 3 5.6 1.3 9.1 2.3 38 10 37 300 6.6 0 6.7 6.5 12/11/2005 06:00:00 6.8 1.2 9.9 3.8 6.3 1.3 9.5 3 5.1 1.2 8 2.3 35 12 32 300 6.7 0 7 6.7 12/11/2005 06:10:00 7.7 1.3 10.7 3 7.2 1.5 10.7 3.4 5.9 1.3 9.5 2.6 39 9 49 300 6.7 0 7 6.7 12/11/2005 06:20:00 6.3 1 9.1 3.8 5.6 1.1 9.1 3 4.4 1.1 7.6 1.9 32 11 30 300 6.6 0 7 6.5 12/11/2005 06:30:00 6.7 1.2 9.5 3 6.2 1.2 9.5 2.3 4.9 1.2 8.4 0.7 35 11 37 300 6.3 0 6.7 6.2 12/11/2005 06:40:00 5.7 1 8.4 3.4 5.3 1.1 8.4 3 4.1 1 6.8 1.5 41 11 32 300 6.2 0 6.5 6.2 12/11/2005 06:50:00 6.1 0.8 8 3.8 5.6 1 8 2.6 4.5 1 8 2.3 39 10 36 300 6.2 0 6.2 6.2 12/11/2005 07:00:00 6.6 1.1 9.1 3.4 6 1.1 8.8 3 4.7 1 8 2.3 37 9 26 300 6.2 0 6.5 6.2 12/11/2005 07:10:00 5.2 1 8 2.6 5.1 1 8.8 2.3 4.1 1 7.6 1.9 46 11 40 300 6.5 0 6.7 6.2 12/11/2005 07:20:00 6.2 1.5 9.9 2.6 6.1 1.5 9.9 2.3 4.5 1.5 8.4 1.1 47 12 43 300 6.2 0 6.5 6.2 12/11/2005 07:30:00 6.8 1 9.1 4.2 6.4 1.1 9.1 3.4 5.1 1.1 7.6 2.6 39 9 40 300 6.2 0 6.5 6.2 12/11/2005 07:40:00 6.5 1.3 9.5 2.6 6.2 1.3 9.1 2.6 4.9 1.1 8 2.6 44 12 43 300 6.2 0 6.2 6 12/11/2005 07:50:00 6.6 1.4 10.7 3 6.2 1.5 10.3 2.6 4.9 1.4 9.1 1.5 41 12 42 300 6.2 0 6.5 6.2 12/11/2005 08:00:00 6.7 1 9.1 4.2 6.5 1.1 8.8 3.4 5 1.2 8.4 2.3 42 11 43 300 6.3 0 6.5 6.2 12/11/2005 08:10:00 5.9 0.8 8.4 4.2 5.8 0.9 8.4 3.4 4.6 1.1 7.6 1.5 40 9 41 300 6.1 0 6.2 6 12/11/2005 08:20:00 6 1.1 9.1 2.6 5.5 1.1 8 1.9 4.5 1.1 8 1.9 37 10 31 300 5.9 0 6 5.7 12/11/2005 08:30:00 6.9 0.8 8.8 4.2 6.3 1 8.8 3.4 5.3 1 8 3 36 10 47 300 5.7 0 6 5.7 12/11/2005 08:40:00 6.2 1.2 8.8 2.6 5.7 1.3 8.4 2.3 4.7 1.3 9.1 1.9 35 13 36 300 5.7 0 5.7 5.7 12/11/2005 08:50:00 5.4 0.8 7.6 3.4 5.1 0.8 7.6 2.3 4.2 0.9 6.5 2.3 37 11 19 300 5.9 0 6 5.7 12/11/2005 09:00:00 5.1 0.9 7.2 2.6 4.7 1 6.8 2.3 3.8 0.9 7.2 1.1 36 12 41 300 5.7 0 5.7 5.7 12/11/2005 09:10:00 5.1 0.8 7.2 2.3 4.9 0.8 7.2 2.3 3.8 1 6.1 1.5 41 12 42 300 5.7 0 5.7 5.5 12/11/2005 09:20:00 5.1 0.8 7.2 2.3 4.8 0.8 6.8 2.3 3.7 0.9 6.5 1.5 37 12 43 300 5.6 0 5.7 5.5 12/11/2005 09:30:00 4.8 0.7 6.5 3 4.4 0.8 6.5 2.3 3.6 0.8 6.1 1.9 32 10 43 300 5.6 0 5.7 5.5 12/11/2005 09:40:00 3.3 1 5.7 1.1 2.9 1 5.3 0.7 2.3 1 4.9 0.4 38 15 41 300 5.5 0 5.7 5.5 12/11/2005 09:50:00 2.7 0.5 4.2 1.5 2.6 0.6 4.2 0.7 1.9 0.6 3.4 0.7 53 11 68 300 5.3 0 5.5 5 12/11/2005 10:00:00 2.8 1 5.3 1.1 2.6 1 5.3 1.1 2.2 1 5.3 0.4 51 10 54 300 5.4 0 5.5 5.2 12/11/2005 10:10:00 2.5 0.4 3.8 1.5 2.3 0.4 3.4 1.1 1.7 0.5 3 0.4 48 9 52 300 5.2 0 5.5 5 12/11/2005 10:20:00 1.8 0.4 3 0.7 1.6 0.5 3.4 0.4 1.3 0.5 2.3 0.4 65 12 57 300 4.6 0.5 5 3.8 12/11/2005 10:30:00 1.3 0.4 2.6 0.4 1.1 0.5 2.3 0.4 1.4 0.4 2.3 0.4 118 27 105 300 2.9 0.5 3.8 2.1 12/11/2005 10:40:00 1.6 0.4 2.3 0.7 1.4 0.5 2.3 0.4 1.5 0.4 2.3 0.4 145 17 101 300 2 0.1 2.3 1.8 12/11/2005 10:50:00 0.8 0.3 1.5 0.4 0.5 0.2 1.5 0.4 0.5 0.2 1.1 0.4 113 18 135 300 1.8 0 1.8 1.8 12/11/2005 11:00:00 0.9 0.4 1.9 0.4 0.6 0.3 1.5 0.4 0.8 0.4 1.9 0.4 127 38 170 300 1.8 0 1.8 1.6 12/11/2005 11:10:00 0.8 0.3 1.5 0.4 0.5 0.2 1.5 0.4 0.4 0.1 0.7 0.4 75 6 68 300 1.7 0 1.8 1.6 12/11/2005 11:20:00 1.6 0.6 3 0.4 1.4 0.7 3 0.4 0.9 0.5 1.9 0.4 87 4 85 300 1.8 0 2.1 1.6 12/11/2005 11:30:00 2.8 0.3 3.4 1.9 2.7 0.3 3.4 1.9 2.2 0.4 3 1.5 86 9 91 300 2.1 0 2.3 1.8 12/11/2005 11:40:00 2.8 0.4 3.8 1.9 2.7 0.4 3.4 1.9 2.3 0.5 3.4 1.5 94 5 93 300 2.3 0 2.6 2.3 12/11/2005 11:50:00 0.7 0.6 2.3 0.4 0.7 0.6 2.3 0.4 0.5 0.3 1.9 0.4 87 1 92 300 2.4 0 2.6 2.3 12/11/2005 12:00:00 0.7 0.5 1.9 0.4 0.6 0.5 1.9 0.4 1 0.4 1.9 0.4 156 20 165 300 2 0.2 2.3 1.8 12/11/2005 12:10:00 0.9 0.4 1.5 0.4 0.8 0.3 1.5 0.4 0.8 0.3 1.5 0.4 130 19 166 300 1.7 0 1.8 1.6 12/11/2005 12:20:00 0.9 0.4 1.5 0.4 0.6 0.3 1.5 0.4 0.4 0.2 1.1 0.4 123 3 123 300 1.5 0 1.6 1.6 12/11/2005 12:30:00 1.1 0.4 1.9 0.4 0.9 0.4 1.5 0.4 0.4 0.2 1.1 0.4 111 2 112 300 1.6 0 1.8 1.6 12/11/2005 12:40:00 1.8 0.2 2.3 1.1 1.6 0.3 2.3 1.1 0.7 0.2 1.1 0.4 98 11 87 300 2 0 2.3 1.8 12/11/2005 12:50:00 1.2 0.5 2.3 0.4 1 0.6 2.6 0.4 1.2 0.5 2.6 0.4 194 39 205 300 2.2 0 2.3 2.1 12/11/2005 13:00:00 0.9 0.6 2.3 0.4 0.8 0.5 1.9 0.4 1 0.6 2.3 0.4 227 13 233 300 1.9 0.1 2.3 1.8 12/11/2005 13:10:00 0.8 0.5 1.9 0.4 0.7 0.4 1.5 0.4 1.3 0.2 1.5 0.4 219 5 228 300 1.8 0 1.8 1.8 12/11/2005 13:20:00 0.6 0.3 1.5 0.4 0.4 0.1 1.1 0.4 0.7 0.3 1.5 0.4 196 33 224 300 1.8 0 1.8 1.8 12/11/2005 13:30:00 0.6 0.3 1.5 0.4 0.4 0.2 1.1 0.4 0.4 0 0.4 0.4 194 23 208 300 2 0 2.3 1.8 12/11/2005 13:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0.2 1.5 0.4 208 0 300 300 2.3 0 2.3 2.1 12/11/2005 13:50:00 0.4 0.2 1.1 0.4 0.4 0 0.7 0.4 0.6 0.4 1.9 0.4 205 1 207 300 2.2 0 2.3 2.1 12/11/2005 14:00:00 0.5 0.2 1.1 0.4 0.4 0 0.4 0.4 0.4 0.1 0.7 0.4 205 0 204 300 2.1 0 2.3 2.1 12/11/2005 14:10:00 0.4 0.1 1.1 0.4 0.4 0 0.4 0.4 0.4 0 0.7 0.4 205 0 205 300 1.9 0 2.1 1.8 12/11/2005 14:20:00 0.4 0.1 0.7 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 205 0 205 300 1.8 0 1.8 1.6 12/11/2005 14:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 205 0 300 300 1.5 0 1.6 1.4 12/11/2005 14:40:00 0.7 0.4 1.5 0.4 0.5 0.3 1.5 0.4 0.9 0.5 1.9 0.4 202 4 205 300 1.2 0 1.6 1.1 12/11/2005 14:50:00 0.5 0.3 1.9 0.4 0.4 0.2 1.5 0.4 0.7 0.4 1.5 0.4 215 7 215 300 1 0 1.1 0.9 12/11/2005 15:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0.1 1.1 0.4 219 0 300 300 0.8 0 0.9 0.7 12/11/2005 15:10:00 0.5 0.3 1.1 0.4 0.4 0.2 1.1 0.4 0.7 0.4 1.5 0.4 194 4 193 300 0.6 0 0.9 0.4 12/11/2005 15:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 193 0 300 300 0.5 0 0.7 0.2 12/11/2005 15:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 193 0 300 300 0.1 0 0.4 0.2 12/11/2005 15:40:00 0.4 0.1 0.7 0.4 0.4 0 0.4 0.4 0.4 0.1 0.7 0.4 193 0 193 300 0 0 0.2 -0.1 12/11/2005 15:50:00 1.1 0.4 1.9 0.4 0.8 0.4 1.9 0.4 0.7 0.3 1.5 0.4 225 13 222 300 0 0 0.2 -0.1 12/11/2005 16:00:00 1.9 0.5 2.6 0.7 1.8 0.5 2.6 0.4 1.4 0.6 2.3 0.4 217 6 222 300 -0.1 0.2 0.2 -0.5 12/11/2005 16:10:00 2.8 1 4.6 0.7 2.8 0.9 4.2 0.7 2.4 0.8 4.6 0.7 221 10 235 300 -0.1 0.2 0.2 -0.5 12/11/2005 16:20:00 3.2 0.5 4.2 1.9 3 0.5 4.2 1.5 2.6 0.5 3.4 0.7 244 5 237 300 0.2 0 0.4 0.2 12/11/2005 16:30:00 2.4 0.4 3.4 1.1 2.1 0.5 3 0.7 1.9 0.4 2.6 0.7 243 9 245 300 0.4 0 0.7 0.2 12/11/2005 16:40:00 2.8 0.4 3.8 1.9 2.6 0.4 3.4 1.5 2.3 0.5 3.4 1.1 245 8 252 300 0.5 0 0.7 0.4 12/11/2005 16:50:00 2.4 0.3 3 1.5 2.1 0.3 3 1.1 2 0.3 3 1.1 250 5 245 300 0.4 0 0.7 0.4 12/11/2005 17:00:00 1.9 0.4 3 1.1 1.5 0.5 3 0.4 1.5 0.4 2.6 0.7 235 8 233 300 0.3 0 0.7 0.2 12/11/2005 17:10:00 2.5 0.4 3.4 1.9 2.3 0.4 3 1.5 1.9 0.4 2.6 1.1 239 8 242 300 0.2 0 0.4 0.2 12/11/2005 17:20:00 2.5 0.4 3.4 1.5 2.2 0.5 3.4 1.1 2 0.4 3 1.1 245 9 236 300 0.2 0 0.4 0.2 12/11/2005 17:30:00 2.3 0.4 3.4 1.5 2 0.5 3.4 1.1 1.9 0.4 3 1.1 246 8 239 300 0.4 0 0.4 0.2 12/11/2005 17:40:00 2.3 0.5 3.4 1.5 2 0.5 3.4 0.7 1.9 0.4 3 1.1 254 8 246 300 0.3 0 0.4 0.2 12/11/2005 17:50:00 1.1 0.3 1.9 0.4 0.5 0.3 1.5 0.4 0.7 0.3 1.9 0.4 259 9 266 300 -0.1 0.1 0.2 -0.3 12/11/2005 18:00:00 0.6 0.3 1.5 0.4 0.4 0.1 1.1 0.4 0.4 0 0.7 0.4 245 7 227 300 -0.2 0 -0.1 -0.3 12/11/2005 18:10:00 0.4 0 0.7 0.4 0.4 0 0.4 0.4 0.8 0.3 1.5 0.4 311 45 356 300 -0.3 0 -0.1 -0.5 12/11/2005 18:20:00 0.4 0 0.7 0.4 0.4 0 0.4 0.4 0.7 0.2 1.1 0.4 12 22 39 300 -0.3 0 -0.1 -0.5 12/11/2005 18:30:00 0.4 0.2 1.1 0.4 0.4 0.1 0.7 0.4 0.6 0.3 1.5 0.4 87 15 66 300 -0.5 0 -0.3 -0.5 12/11/2005 18:40:00 0.4 0 0.7 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 136 16 142 300 -0.7 0 -0.5 -0.7 12/11/2005 18:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.5 0.3 1.5 0.4 98 56 300 300 -0.7 0 -0.5 -0.7 12/11/2005 19:00:00 0.4 0.1 0.7 0.4 0.4 0 0.7 0.4 0.5 0.2 1.1 0.4 349 47 299 300 -0.9 0.1 -0.5 -1 12/11/2005 19:10:00 0.5 0.2 1.5 0.4 0.4 0 0.7 0.4 0.4 0.1 1.1 0.4 282 14 299 300 -1 0 -0.7 -1.2 12/11/2005 19:20:00 0.8 0.4 1.9 0.4 0.4 0.2 1.5 0.4 0.4 0.1 0.7 0.4 249 11 235 300 -1.2 0 -1 -1.2 12/11/2005 19:30:00 1.3 0.3 1.9 0.4 0.7 0.3 1.5 0.4 0.8 0.3 1.5 0.4 250 5 247 300 -1.4 0.1 -1.2 -1.4 12/11/2005 19:40:00 1.3 0.2 1.9 0.7 0.6 0.2 1.5 0.4 0.8 0.3 1.5 0.4 251 5 247 300 -1.4 0 -1.2 -1.4 12/11/2005 19:50:00 1.1 0.3 1.9 0.4 0.5 0.2 1.1 0.4 0.7 0.2 1.1 0.4 251 8 251 300 -1.6 0 -1.4 -1.7 12/11/2005 20:00:00 1.2 0.3 1.9 0.4 0.6 0.3 1.5 0.4 1 0.3 1.9 0.4 271 7 264 300 -1.6 0 -1.4 -1.4 12/11/2005 20:10:00 1.5 0.2 1.9 1.1 0.9 0.3 1.5 0.4 1.1 0.2 1.5 0.7 266 5 264 300 -1.5 0 -1.2 -1.7 12/11/2005 20:20:00 1.3 0.2 1.5 0.7 0.7 0.2 1.5 0.4 1.1 0.2 1.5 0.7 283 9 268 300 -1.8 0 -1.7 -2.1 12/11/2005 20:30:00 1.3 0.2 1.9 0.7 0.7 0.3 1.5 0.4 1.1 0.2 1.5 0.7 290 5 288 300 -1.7 0 -1.4 -1.9 12/11/2005 20:40:00 0.5 0.2 1.1 0.4 0.4 0 0.4 0.4 0.5 0.2 1.5 0.4 300 0 300 300 -1.7 0.1 -1.2 -1.9 12/11/2005 20:50:00 0.4 0.1 1.1 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 300 0 301 300 -1.7 0.2 -1.4 -2.1 12/11/2005 21:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.5 0.2 1.1 0.4 303 16 300 300 -2 0.1 -1.4 -2.1 12/11/2005 21:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0.1 0.7 0.4 44 0 300 300 -2.1 0 -2.1 -2.1 12/11/2005 21:20:00 0.4 0.1 0.7 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 153 56 169 300 -2.1 0 -1.9 -2.1 12/11/2005 21:30:00 0.4 0 0.7 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 187 0 187 300 -2.2 0 -2.1 -2.4 12/11/2005 21:40:00 0.4 0.1 0.7 0.4 0.4 0 0.4 0.4 0.4 0 0.7 0.4 185 7 160 300 -2.4 0 -2.4 -2.6 12/11/2005 21:50:00 1 0.3 1.5 0.4 0.6 0.3 1.5 0.4 0.6 0.3 1.1 0.4 121 16 117 300 -2.4 0 -2.4 -2.6 12/11/2005 22:00:00 1.6 0.3 2.3 1.1 1.4 0.3 2.3 0.7 1.2 0.2 1.5 0.7 89 10 81 300 -2.4 0 -2.1 -2.4 12/11/2005 22:10:00 2 0.2 2.6 1.5 1.9 0.3 2.6 1.5 1.4 0.3 2.3 0.7 67 6 57 300 -2.4 0 -2.1 -2.6 12/11/2005 22:20:00 2.5 0.3 3 1.5 2.5 0.3 3 1.5 2 0.3 2.6 1.1 59 3 57 300 -2.1 0.1 -1.7 -2.4 12/11/2005 22:30:00 2.3 0.2 2.6 1.9 2.2 0.2 2.6 1.5 2.2 0.2 2.6 1.5 60 3 62 300 -1.6 0 -1.4 -1.7 12/11/2005 22:40:00 2 0.2 2.3 1.5 1.8 0.2 2.3 1.1 1.8 0.5 2.6 0.4 54 3 55 300 -1.4 0 -1.2 -1.4 12/11/2005 22:50:00 0.9 0.6 2.3 0.4 0.7 0.5 1.9 0.4 1.1 0.5 2.3 0.4 55 47 46 300 -0.9 0.2 -0.5 -1.2 12/11/2005 23:00:00 0.6 0.4 1.9 0.4 0.4 0.2 1.5 0.4 0.6 0.3 1.5 0.4 333 36 297 300 -0.8 0 -0.7 -1 12/11/2005 23:10:00 1.3 0.4 2.3 0.4 0.8 0.5 2.3 0.4 1.1 0.4 1.9 0.4 277 12 278 300 -0.6 0 -0.5 -0.7 12/11/2005 23:20:00 1 0.4 1.9 0.4 0.5 0.2 1.5 0.4 0.4 0.2 1.1 0.4 266 8 250 300 -0.7 0.1 -0.5 -0.7 12/11/2005 23:30:00 1 0.3 1.5 0.4 0.4 0.2 1.5 0.4 0.6 0.3 1.1 0.4 247 7 254 300 -0.7 0 -0.5 -0.7 12/11/2005 23:40:00 0.4 0.1 1.1 0.4 0.4 0 0.4 0.4 0.4 0 0.7 0.4 226 2 226 300 -0.6 0 -0.5 -0.7 12/11/2005 23:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.8 0.3 1.5 0.4 280 49 300 300 -0.6 0 -0.5 -0.7 12/12/2005 00:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0.1 1.1 0.4 326 0 300 300 -0.6 0 -0.5 -0.7 12/12/2005 00:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.5 0.2 1.5 0.4 326 0 300 300 -0.6 0 -0.5 -0.7 12/12/2005 00:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 277 27 300 300 -0.6 0 -0.5 -0.7 12/12/2005 00:30:00 0.4 0 0.7 0.4 0.4 0 0.4 0.4 0.4 0.2 1.1 0.4 266 13 316 300 -0.5 0 -0.5 -0.5 12/12/2005 00:40:00 2 0.8 3.4 0.4 1.9 1 3.4 0.4 1.9 0.6 3 0.4 339 12 336 300 -0.5 0 -0.5 -0.7 12/12/2005 00:50:00 2.8 0.4 3.8 1.9 2.8 0.4 3.8 1.9 2.3 0.5 3.4 1.1 338 5 339 300 -0.5 0 -0.5 -0.5 12/12/2005 01:00:00 3 0.4 4.2 1.9 2.9 0.5 4.2 1.5 2.5 0.4 3.8 1.5 321 11 309 300 -0.5 0 -0.5 -0.5 12/12/2005 01:10:00 2.9 0.4 3.8 1.9 2.9 0.5 3.8 1.5 2.2 0.4 3.4 1.1 314 9 302 300 -0.4 0 -0.3 -0.5 12/12/2005 01:20:00 2.7 0.6 4.2 1.1 2.6 0.7 4.2 1.1 2.3 0.5 3.4 1.1 311 9 285 300 -0.2 0 0.2 -0.5 12/12/2005 01:30:00 2.9 0.5 4.2 1.5 2.8 0.6 4.6 1.1 2.3 0.6 3.8 0.7 307 10 295 300 0.2 0 0.4 -0.1 12/12/2005 01:40:00 3.2 0.6 4.9 1.9 3.1 0.6 4.9 1.5 2.8 0.5 4.2 1.5 297 11 295 300 0.6 0 0.9 0.4 12/12/2005 01:50:00 3.2 0.6 4.6 1.5 3.1 0.6 4.6 1.9 2.8 0.6 4.2 1.1 294 9 299 300 0.8 0 0.9 0.7 12/12/2005 02:00:00 3.4 0.7 5.3 1.5 3.3 0.7 5.3 1.1 2.9 0.6 4.9 1.5 283 11 273 300 1.1 0 1.4 0.9 12/12/2005 02:10:00 3 0.7 4.9 1.9 2.9 0.8 4.6 1.5 2.8 0.7 4.9 1.5 271 17 282 300 1.2 0 1.4 1.1 12/12/2005 02:20:00 3.9 0.8 5.7 1.9 3.8 0.8 6.1 1.9 3.6 0.8 5.7 2.3 261 13 256 300 1.2 0 1.4 1.4 12/12/2005 02:30:00 3.1 0.8 5.7 1.5 3 0.8 5.3 1.5 2.9 0.7 4.9 1.5 266 15 234 300 1.2 0 1.4 1.1 12/12/2005 02:40:00 3 0.6 4.6 1.5 2.9 0.6 4.2 1.1 2.8 0.6 4.6 1.1 275 11 274 300 1.1 0 1.4 0.9 12/12/2005 02:50:00 3.5 0.7 5.3 1.9 3.3 0.7 4.9 1.5 3 0.7 4.9 1.5 277 10 264 300 1 0 1.1 0.9 12/12/2005 03:00:00 3.7 0.7 5.3 1.9 3.6 0.7 5.3 1.9 3.5 0.7 5.3 2.3 272 8 280 300 0.9 0 1.1 0.9 12/12/2005 03:10:00 3.6 0.5 4.9 1.9 3.5 0.6 4.9 2.3 3.2 0.5 4.6 2.3 276 10 278 300 0.8 0 0.9 0.7 12/12/2005 03:20:00 3.5 0.6 4.9 1.9 3.3 0.6 4.9 1.9 3.1 0.6 4.9 1.9 272 10 272 300 0.8 0 0.9 0.7 12/12/2005 03:30:00 4 0.7 6.1 2.3 3.9 0.7 6.1 1.9 3.7 0.7 5.7 1.9 265 11 258 300 0.7 0 0.9 0.7 12/12/2005 03:40:00 4.7 0.8 6.8 2.6 4.5 0.8 6.8 2.6 4.1 0.9 6.1 2.3 255 12 251 300 0.7 0 0.7 0.7 12/12/2005 03:50:00 4.3 0.6 5.7 3 4.1 0.6 5.7 2.6 3.8 0.7 5.7 2.3 261 10 265 300 0.7 0 0.7 0.7 12/12/2005 04:00:00 4 0.9 6.1 1.5 3.9 1 5.7 1.1 3.6 0.7 5.3 1.9 254 12 250 300 0.6 0 0.7 0.7 12/12/2005 04:10:00 3.5 0.9 6.1 1.5 3.4 0.9 6.1 1.9 3.2 0.8 5.7 1.9 256 9 244 300 0.5 0 0.7 0.7 12/12/2005 04:20:00 3.7 0.6 5.7 1.9 3.6 0.6 4.9 1.9 3.1 0.7 4.6 1.1 247 13 233 300 0.5 0 0.7 0.4 12/12/2005 04:30:00 3.5 0.6 5.3 1.9 3.3 0.6 4.9 1.5 2.8 0.7 4.6 0.7 241 13 262 300 0.4 0 0.7 0.2 12/12/2005 04:40:00 2.5 0.6 4.2 1.5 2.4 0.6 3.8 1.1 2.1 0.6 3.8 1.1 240 11 244 300 0.2 0 0.2 0.2 12/12/2005 04:50:00 2.2 0.5 3.4 0.7 2 0.5 3 0.4 1.7 0.5 2.6 0.4 237 14 243 300 0.2 0 0.4 0.2 12/12/2005 05:00:00 1.8 0.5 3.4 0.7 1.5 0.6 3 0.4 1.5 0.6 2.6 0.4 253 14 254 300 0.3 0 0.4 0.2 12/12/2005 05:10:00 1.9 0.4 2.6 1.1 1.6 0.5 2.6 0.7 1.8 0.4 2.6 0.7 270 10 259 300 0.2 0 0.4 0.2 12/12/2005 05:20:00 2.2 0.6 3.8 0.7 1.9 0.8 3.4 0.4 2.1 0.6 3.4 0.7 270 15 251 300 0.2 0 0.4 0.2 12/12/2005 05:30:00 3.1 0.7 4.9 1.5 3 0.7 4.9 1.5 2.8 0.8 4.9 1.5 253 15 254 300 0.1 0 0.4 0.2 12/12/2005 05:40:00 3.2 0.6 4.9 1.9 3.1 0.6 4.6 1.9 2.8 0.6 4.6 1.5 253 8 252 300 0.1 0 0.2 -0.1 12/12/2005 05:50:00 3.3 0.5 4.9 1.9 3.2 0.5 4.6 1.9 2.8 0.6 4.2 1.5 251 9 247 300 0.1 0 0.2 -0.1 12/12/2005 06:00:00 3.3 0.9 5.3 1.1 3.2 0.9 4.9 0.7 2.8 0.8 4.9 1.1 243 13 226 300 0.1 0 0.2 -0.1 12/12/2005 06:10:00 3 0.8 4.9 1.1 2.9 0.8 4.6 0.7 2.7 0.7 4.6 0.7 241 14 225 300 -0.1 0 0.2 -0.1 12/12/2005 06:20:00 3.7 0.8 5.7 1.9 3.5 0.8 5.7 1.5 3.3 0.8 5.7 1.1 234 11 239 300 -0.2 0 -0.1 -0.3 12/12/2005 06:30:00 3.5 0.7 4.9 1.9 3.5 0.7 4.9 1.9 3 0.8 4.9 1.1 236 13 232 300 -0.3 0 -0.1 -0.3 12/12/2005 06:40:00 3.7 1 5.7 1.1 3.6 1 5.7 1.1 3.2 0.9 5.7 1.1 242 13 240 300 -0.3 0 -0.1 -0.3 12/12/2005 06:50:00 3.8 0.8 5.7 1.9 3.7 0.8 5.3 1.9 3.4 0.8 5.7 1.1 245 13 245 300 -0.2 0 -0.1 -0.3 12/12/2005 07:00:00 3.6 1.1 6.5 1.1 3.4 1.1 6.1 0.7 3.3 1 5.7 1.1 235 15 236 300 -0.2 0 -0.1 -0.3 12/12/2005 07:10:00 4 0.9 5.7 1.9 3.9 0.8 5.7 1.5 3.5 0.8 5.3 1.5 236 13 236 300 -0.3 0 -0.1 -0.5 12/12/2005 07:20:00 3.8 1.1 6.5 1.5 3.7 1.1 6.1 1.1 3.4 1 5.7 1.5 235 13 240 300 -0.5 0 -0.5 -0.5 12/12/2005 07:30:00 3.3 0.7 6.5 1.9 3.2 0.8 6.1 1.5 3 0.9 6.1 1.1 236 15 217 300 -0.5 0 -0.3 -0.5 12/12/2005 07:40:00 4.3 0.8 6.8 2.3 4.2 0.8 6.5 1.9 3.8 0.9 6.8 1.5 232 11 238 300 -0.5 0 -0.5 -0.5 12/12/2005 07:50:00 3.7 0.8 5.7 1.5 3.6 0.7 5.7 1.5 3.1 0.7 4.9 1.1 229 16 220 300 -0.5 0 -0.5 -0.5 12/12/2005 08:00:00 3.2 0.7 5.3 1.1 3 0.7 4.9 1.1 2.9 0.7 4.6 1.1 231 15 228 300 -0.5 0 -0.3 -0.5 12/12/2005 08:10:00 4.2 1 6.5 1.5 4.1 0.9 6.5 1.9 3.6 1 6.5 1.1 232 12 233 300 -0.5 0 -0.5 -0.5 12/12/2005 08:20:00 3.1 1 5.3 0.4 3 1 4.9 0.4 2.7 0.7 4.6 0.7 231 17 226 300 -0.5 0 -0.5 -0.5 12/12/2005 08:30:00 3 0.8 4.9 0.7 2.9 0.8 4.6 0.7 2.7 0.7 4.9 0.7 227 15 224 300 -0.5 0 -0.3 -0.5 12/12/2005 08:40:00 2.6 0.8 4.6 0.4 2.5 0.8 4.2 0.4 2.2 0.8 4.2 0.4 228 17 261 300 -0.5 0 -0.5 -0.5 12/12/2005 08:50:00 3 1 5.3 1.1 2.9 1 5.3 0.4 2.7 0.8 5.3 0.4 237 16 233 300 -0.5 0 -0.5 -0.5 12/12/2005 09:00:00 3.1 0.7 5.7 1.1 3 0.8 5.3 1.1 2.7 0.8 4.9 1.1 238 16 228 300 -0.6 0 -0.5 -0.7 12/12/2005 09:10:00 3.7 0.8 5.7 1.5 3.6 0.9 5.3 1.1 3.2 0.9 5.3 0.4 247 15 234 300 -0.7 0 -0.5 -0.7 12/12/2005 09:20:00 3.8 0.6 5.3 2.3 3.7 0.6 4.9 2.3 3.3 0.7 5.3 1.5 255 8 249 300 -0.9 0 -0.7 -0.7 12/12/2005 09:30:00 3.3 0.7 5.3 1.5 3.1 0.8 4.9 1.1 2.8 0.6 4.9 1.1 266 9 268 300 -0.9 0 -0.7 -0.7 12/12/2005 09:40:00 1.5 0.6 3 0.4 1.3 0.6 2.6 0.4 1.2 0.6 3 0.4 235 18 237 300 -0.9 0 -0.7 -1 12/12/2005 09:50:00 2.6 0.5 3.8 1.5 2.4 0.5 3.8 1.1 2.1 0.6 3.8 0.7 229 12 236 300 -1 0 -0.7 -1 12/12/2005 10:00:00 2.9 0.5 4.6 1.9 2.7 0.5 4.2 1.5 2.7 0.5 3.8 1.5 261 10 261 300 -1 0 -1 -1.2 12/12/2005 10:10:00 2.2 0.6 3.4 0.7 2 0.6 3.4 0.7 2.1 0.6 3.4 0.7 268 8 275 300 -1 0 -1 -1.2 12/12/2005 10:20:00 1.9 0.8 3.4 0.7 1.6 0.9 3.4 0.4 1.9 0.8 3.4 0.4 266 11 256 300 -1.1 0 -1 -1.2 12/12/2005 10:30:00 1.7 0.7 3 0.4 1.5 0.8 3 0.4 1.9 0.6 3.4 0.7 272 10 272 300 -1.2 0 -1.2 -1.2 12/12/2005 10:40:00 1.7 0.5 2.6 0.4 1.4 0.5 2.6 0.4 1.6 0.4 2.6 0.7 266 10 275 300 -1.3 0 -1.2 -1.2 12/12/2005 10:50:00 2 0.5 3 0.7 1.7 0.5 3 0.4 1.7 0.5 3.4 0.7 271 14 270 300 -1.3 0 -1.2 -1.4 12/12/2005 11:00:00 2.1 0.5 3.4 1.1 1.8 0.6 3.4 0.4 1.9 0.4 3 0.7 275 15 288 300 -1.4 0 -1.2 -1.4 12/12/2005 11:10:00 1.1 0.5 2.6 0.4 0.6 0.5 2.6 0.4 1.1 0.5 2.6 0.4 262 8 263 300 -1.4 0 -1.2 -1.4 12/12/2005 11:20:00 1 0.4 1.9 0.4 0.4 0 0.4 0.4 0.8 0.4 1.9 0.4 244 16 216 300 -1.4 0 -1.2 -1.4 12/12/2005 11:30:00 0.8 0.4 1.9 0.4 0.4 0 0.4 0.4 0.9 0.4 1.9 0.4 205 10 223 300 -1.4 0 -1.2 -1.4 12/12/2005 11:40:00 1.2 0.4 2.3 0.4 0.4 0 0.4 0.4 1.1 0.4 1.9 0.4 214 10 220 300 -1.3 0 -1.2 -1.4 12/12/2005 11:50:00 2.5 0.8 4.6 0.4 2 1.2 4.6 0.4 2.2 0.7 4.2 0.7 225 14 234 300 -1.3 0 -1.2 -1.4 12/12/2005 12:00:00 3.3 0.9 5.3 1.1 3.2 0.9 5.3 1.1 2.8 0.9 4.9 0.7 227 15 232 300 -1.5 0 -1.2 -1.7 12/12/2005 12:10:00 3.6 0.7 5.3 1.5 3.5 0.7 5.3 1.5 2.9 0.8 4.9 1.1 226 16 241 300 -1.7 0 -1.4 -1.9 12/12/2005 12:20:00 4 1.1 6.5 1.5 3.9 1 6.5 1.5 3.5 0.9 5.7 1.1 227 14 235 300 -1.8 0 -1.7 -1.9 12/12/2005 12:30:00 4.3 0.8 6.1 1.9 4.4 0.8 6.1 2.3 3.6 0.8 5.7 1.5 223 13 216 300 -2 0 -1.9 -2.1 12/12/2005 12:40:00 4.4 1.1 6.8 1.9 4.5 1.1 6.5 1.5 3.8 1 6.5 1.5 221 15 219 300 -2.1 0 -1.9 -2.1 12/12/2005 12:50:00 4.1 0.9 6.5 2.3 4.2 0.8 6.5 2.6 3.5 0.8 5.7 1.5 221 13 223 300 -2.1 0 -1.9 -2.1 12/12/2005 13:00:00 4.7 1 6.8 2.3 4.6 1 6.8 2.3 3.9 0.9 6.5 1.9 235 13 231 300 -2.2 0 -2.1 -2.4 12/12/2005 13:10:00 3.9 1 6.1 1.5 4 1 6.1 1.5 3.5 0.9 5.7 1.5 224 15 224 300 -2.4 0 -2.1 -2.4 12/12/2005 13:20:00 4.1 0.9 6.5 1.9 4.4 0.9 6.8 1.9 3.7 1 6.8 1.5 216 16 195 300 -2.2 0 -2.1 -2.4 12/12/2005 13:30:00 4.2 1 7.6 2.3 4.6 1 8 2.3 3.8 1 6.5 1.9 215 15 206 300 -2.4 0 -2.1 -2.4 12/12/2005 13:40:00 4.4 0.8 6.1 1.9 4.9 0.8 6.5 2.6 4 1 7.2 1.9 214 13 220 300 -2.4 0 -2.1 -2.6 12/12/2005 13:50:00 3.6 0.7 5.7 1.5 4.1 0.8 6.5 1.9 3.6 0.7 5.7 1.9 210 13 200 300 -2.5 0 -2.4 -2.6 12/12/2005 14:00:00 3 0.7 4.9 1.5 3.4 0.8 5.3 1.5 2.9 0.8 5.3 1.1 205 12 188 300 -2.6 0 -2.6 -2.6 12/12/2005 14:10:00 3.1 0.7 5.3 1.1 3.7 0.8 5.3 1.5 3.3 0.7 4.9 1.5 206 10 198 300 -2.6 0 -2.6 -2.6 12/12/2005 14:20:00 3.2 0.7 4.9 1.5 3.4 0.7 4.9 1.9 3.1 0.7 4.6 1.1 194 10 195 300 -2.6 0 -2.6 -2.6 12/12/2005 14:30:00 3.5 0.6 4.9 1.9 3.5 0.6 5.3 1.9 3 0.6 4.9 1.5 187 9 200 300 -2.6 0 -2.6 -2.6 12/12/2005 14:40:00 3 0.8 4.6 1.1 3 0.8 4.9 1.1 2.6 0.6 4.2 1.1 184 11 179 300 -2.6 0 -2.6 -2.6 12/12/2005 14:50:00 3.2 0.7 4.9 1.5 3.2 0.7 4.9 1.1 2.7 0.7 4.6 0.7 185 11 181 300 -2.5 0 -2.4 -2.6 12/12/2005 15:00:00 3.3 0.7 5.3 1.5 3.3 0.6 4.9 1.1 2.8 0.6 4.2 1.5 183 9 183 300 -2.6 0 -2.6 -2.6 12/12/2005 15:10:00 3.3 0.5 4.6 1.9 3.2 0.5 4.6 1.9 2.7 0.6 4.2 1.1 176 9 181 300 -2.6 0 -2.6 -2.6 12/12/2005 15:20:00 1.6 0.6 3 0.4 1.5 0.7 3.4 0.4 1.4 0.5 3 0.4 178 11 175 300 -2.6 0 -2.6 -2.8 12/12/2005 15:30:00 1.7 0.5 3 0.4 1.6 0.5 3 0.4 1.3 0.5 2.6 0.4 183 11 179 300 -2.8 0 -2.6 -2.8 12/12/2005 15:40:00 2.4 0.6 4.2 1.1 2.3 0.6 4.2 0.7 2.2 0.7 3.8 0.4 186 8 189 300 -2.8 0 -2.8 -2.8 12/12/2005 15:50:00 1.4 0.4 2.3 0.4 1.2 0.5 2.3 0.4 1.2 0.4 1.9 0.4 171 13 181 300 -3 0 -2.8 -3.3 12/12/2005 16:00:00 0.8 0.4 2.3 0.4 0.6 0.4 1.9 0.4 0.5 0.3 1.5 0.4 146 13 153 300 -3.1 0 -3 -3.3 12/12/2005 16:10:00 0.4 0.2 1.1 0.4 0.4 0.1 0.7 0.4 0.4 0 0.7 0.4 128 17 157 300 -3.1 0 -2.8 -3.3 12/12/2005 16:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0.2 1.1 0.4 128 2 300 300 -3.2 0 -3 -3.3 12/12/2005 16:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.6 0.3 1.5 0.4 101 22 300 300 -3.2 0 -3.3 -3.3 12/12/2005 16:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0.1 0.7 0.4 81 0 300 300 -3.3 0 -3.3 -3.5 12/12/2005 16:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 81 0 300 300 -3.4 0 -3.3 -3.5 12/12/2005 17:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0.1 0.7 0.4 81 0 300 300 -3.4 0 -3.3 -3.5 12/12/2005 17:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 135 24 300 300 -3.4 0 -3.3 -3.5 12/12/2005 17:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.7 0.5 1.9 0.4 118 53 300 300 -3.3 0 -3.3 -3.5 12/12/2005 17:30:00 0.6 0.3 1.5 0.4 0.4 0.1 1.1 0.4 1.4 0.3 2.3 0.7 357 2 352 300 -3.2 0 -3.3 -3.3 12/12/2005 17:40:00 1.9 0.4 2.6 1.1 1.8 0.5 2.6 0.7 1.6 0.5 2.6 0.7 0 12 343 300 -3.2 0 -3.3 -3.3 12/12/2005 17:50:00 2 0.3 2.6 1.1 2 0.3 2.6 1.1 1.3 0.4 2.3 0.7 11 5 9 300 -3.2 0 -3.3 -3.3 12/12/2005 18:00:00 1.9 0.2 2.3 1.5 1.6 0.3 2.3 0.7 1.3 0.3 2.3 0.7 22 6 13 300 -3.2 0 -3.3 -3.3 12/12/2005 18:10:00 2.3 0.3 3 1.9 2.3 0.4 3 1.1 1.7 0.3 2.3 0.7 10 7 10 300 -3.3 0 -3.3 -3.5 12/12/2005 18:20:00 2.5 0.3 3 1.1 2.5 0.4 3 1.1 1.8 0.4 3 0.7 4 5 4 300 -3.5 0 -3.3 -3.5 12/12/2005 18:30:00 2.7 0.3 3.4 1.5 2.8 0.3 3.4 1.5 2 0.4 3 0.7 6 3 2 300 -3.5 0 -3.3 -3.5 12/12/2005 18:40:00 3 0.3 3.8 1.9 3.1 0.3 3.8 1.9 2.3 0.4 3.4 1.1 1 4 358 300 -3.5 0 -3.5 -3.5 12/12/2005 18:50:00 3 0.3 3.8 2.3 3.1 0.3 3.8 2.3 2.3 0.4 3 1.5 4 3 1 300 -3.5 0 -3.5 -3.5 12/12/2005 19:00:00 3.1 0.3 3.4 2.3 3.1 0.2 3.4 2.6 2.4 0.3 3 1.5 359 5 7 300 -3.6 0 -3.5 -3.7 12/12/2005 19:10:00 2.5 0.5 3.4 1.5 2.5 0.5 3.4 1.5 2.2 0.4 3 1.1 342 8 343 300 -3.6 0 -3.5 -3.7 12/12/2005 19:20:00 3.3 0.4 4.2 2.3 3.3 0.4 4.6 2.3 2.5 0.4 3.4 1.5 336 4 338 300 -3.8 0 -3.7 -3.9 12/12/2005 19:30:00 3.5 0.3 4.2 2.6 3.5 0.3 4.2 2.6 2.7 0.4 3.4 1.9 343 4 346 300 -3.8 0 -3.7 -3.9 12/12/2005 19:40:00 3.8 0.3 4.6 2.6 3.9 0.3 4.6 2.6 3 0.3 3.8 1.9 349 2 351 300 -4.1 0.1 -3.9 -4.4 12/12/2005 19:50:00 4.2 0.2 4.6 3.4 4.2 0.2 4.6 3.4 3.2 0.4 4.2 1.9 349 2 352 300 -4.2 0 -3.9 -4.4 12/12/2005 20:00:00 3.8 0.3 4.6 3 3.8 0.3 4.6 3 2.8 0.4 3.8 1.5 348 3 346 300 -4.3 0 -4.2 -4.6 12/12/2005 20:10:00 3.4 0.3 4.2 2.6 3.5 0.3 4.2 2.6 2.4 0.4 3.4 1.5 350 3 352 300 -4.5 0.1 -4.4 -4.6 12/12/2005 20:20:00 3.5 0.3 4.2 2.6 3.5 0.3 4.2 2.3 2.6 0.4 3.4 1.1 348 3 348 300 -4.8 0 -4.6 -5 12/12/2005 20:30:00 2.9 0.7 4.2 1.1 2.9 0.7 4.2 1.1 1.9 0.6 3.4 0.7 356 8 348 300 -4.9 0 -4.8 -5 12/12/2005 20:40:00 1.8 0.7 3 0.4 1.7 0.8 3 0.4 1.1 0.5 2.3 0.4 16 8 3 300 -5.2 0 -4.8 -5.5 12/12/2005 20:50:00 1.9 0.4 2.6 0.7 1.5 0.4 2.3 0.7 1.2 0.5 1.9 0.4 21 3 22 300 -5.4 0 -5.3 -5.5 12/12/2005 21:00:00 2.1 0.2 2.6 1.5 2 0.3 2.6 1.5 1.7 0.2 2.3 1.1 37 3 36 300 -5.8 0.1 -5.5 -5.9 12/12/2005 21:10:00 2.4 0.2 3 1.9 2.2 0.2 2.6 1.5 1.6 0.4 2.3 0.7 31 3 31 300 -6 0 -5.9 -6.1 12/12/2005 21:20:00 2.7 0.2 3.4 2.3 2.3 0.3 3 1.5 1.8 0.3 2.3 1.1 25 3 25 300 -5.9 0 -5.7 -5.9 12/12/2005 21:30:00 2.8 0.2 3.4 2.3 2.7 0.3 3.4 1.9 2.2 0.4 3 1.5 34 5 41 300 -6 0 -5.9 -6.1 12/12/2005 21:40:00 3.5 0.4 4.2 2.3 3.4 0.5 4.6 1.9 2.4 0.5 3.8 1.1 35 5 36 300 -6 0 -5.9 -6.1 12/12/2005 21:50:00 3.6 0.4 4.6 1.9 3.3 0.5 4.2 1.1 1.8 0.5 3 0.4 27 7 14 300 -6 0 -5.9 -6.1 12/12/2005 22:00:00 3.4 0.3 4.2 2.6 3.4 0.3 4.2 2.3 1.9 0.3 3 1.1 39 5 38 300 -5.8 0 -5.5 -5.9 12/12/2005 22:10:00 3.1 0.3 3.8 2.3 3.1 0.3 3.8 1.9 2 0.4 3 1.1 45 5 53 300 -5.5 0.1 -5.5 -5.9 12/12/2005 22:20:00 3.2 0.3 3.8 2.3 3.2 0.3 3.8 1.9 2 0.3 2.6 1.1 42 5 32 300 -5.6 0.2 -5.5 -5.9 12/12/2005 22:30:00 3.3 0.3 4.2 2.6 3.3 0.3 4.2 2.6 2.3 0.4 3.4 1.1 43 6 54 300 -5.4 0 -5.3 -5.5 12/12/2005 22:40:00 3.4 0.4 4.2 1.9 3.4 0.4 4.2 1.9 2.3 0.4 3.4 1.5 44 5 35 300 -5.6 0.1 -5.5 -5.7 12/12/2005 22:50:00 3.6 0.3 4.6 2.6 3.5 0.4 4.6 2.3 2.5 0.5 3.8 1.1 42 5 43 300 -5.8 0 -5.5 -5.9 12/12/2005 23:00:00 4.2 0.4 5.3 3 4.2 0.4 5.3 2.6 3.1 0.4 4.2 1.9 45 5 52 300 -5.7 0 -5.5 -5.9 12/12/2005 23:10:00 4.2 0.4 5.3 3 4.2 0.4 4.9 3.4 2.8 0.5 4.2 1.5 48 6 43 300 -5.9 0 -5.7 -5.9 12/12/2005 23:20:00 3.9 0.5 5.3 2.6 3.9 0.4 5.3 3 2.6 0.5 4.2 1.1 50 6 47 300 -5.9 0 -5.7 -5.9 12/12/2005 23:30:00 4.3 0.5 5.3 3 4.4 0.5 5.3 2.6 2.9 0.6 4.2 1.1 46 6 59 300 -5.9 0 -5.7 -5.9 12/12/2005 23:40:00 4.4 0.5 5.7 3 4.2 0.7 5.7 2.3 2.9 0.6 4.6 1.1 40 8 40 300 -5.6 0 -5.5 -5.7 12/12/2005 23:50:00 4.2 0.8 5.3 1.5 3.8 0.7 5.3 1.5 2.3 0.7 3.8 0.4 27 11 42 300 -5.6 0 -5.5 -5.7 12/13/2005 00:00:00 3.9 0.8 5.7 0.4 3.6 0.9 5.3 0.4 2.1 0.8 3.8 0.4 27 13 28 300 -5.8 0 -5.7 -5.9 12/13/2005 00:10:00 3.9 0.8 5.7 1.9 3.6 0.9 5.7 1.1 1.9 0.8 3.8 0.4 27 15 34 300 -5.6 0 -5.5 -5.7 12/13/2005 00:20:00 3.9 0.7 5.3 2.3 3.5 0.7 5.3 1.9 2.1 0.7 3.8 0.4 27 12 24 300 -5.5 0 -5.5 -5.5 12/13/2005 00:30:00 3.6 0.7 5.3 1.9 3.3 0.7 5.3 1.5 1.9 0.8 3.8 0.4 27 13 33 300 -5.4 0 -5.5 -5.5 12/13/2005 00:40:00 3.8 0.7 5.7 1.9 3.5 0.7 5.3 1.5 1.9 0.7 3.8 0.4 28 12 36 300 -5.6 0 -5.5 -5.7 12/13/2005 00:50:00 3.7 0.6 5.3 2.3 3.3 0.6 4.6 1.5 1.9 0.6 3.8 0.7 27 11 33 300 -5.7 0 -5.5 -5.9 12/13/2005 01:00:00 3.5 0.5 4.6 2.3 3.1 0.5 4.6 1.9 1.9 0.6 3.4 0.7 27 9 46 300 -5.9 0 -5.7 -6.1 12/13/2005 01:10:00 3.5 0.5 4.6 2.3 3.1 0.6 4.6 1.9 1.8 0.7 3.4 0.4 22 10 22 300 -6.2 0 -5.9 -6.4 12/13/2005 01:20:00 3.2 0.8 4.9 0.7 2.9 0.8 4.6 0.7 1.7 0.6 3 0.4 24 13 20 300 -6.2 0.1 -5.9 -6.4 12/13/2005 01:30:00 3.8 0.5 5.3 2.3 3.7 0.6 5.3 2.3 2.2 0.5 3.4 1.1 32 9 45 300 -6.5 0 -6.4 -6.6 12/13/2005 01:40:00 3.9 0.5 5.3 2.6 3.6 0.5 4.9 2.3 2.3 0.5 4.2 1.1 32 8 31 300 -6.5 0 -6.1 -6.6 12/13/2005 01:50:00 4.2 0.6 6.1 2.3 3.9 0.7 5.3 1.9 2.4 0.6 4.2 1.1 32 8 35 300 -6.6 0 -6.6 -6.6 12/13/2005 02:00:00 4.2 0.5 5.7 3 4 0.5 5.7 2.3 2.7 0.6 4.6 1.1 34 8 40 300 -6.5 0 -6.6 -6.6 12/13/2005 02:10:00 4.5 0.5 5.7 3 4.3 0.6 5.7 2.6 2.7 0.6 4.2 1.5 35 8 29 300 -6.5 0 -6.6 -6.8 12/13/2005 02:20:00 4.3 0.5 5.7 2.6 4.1 0.6 5.7 2.3 2.7 0.6 4.2 1.1 40 8 41 300 -6.5 0 -6.6 -6.6 12/13/2005 02:30:00 4.7 0.5 5.7 3 4.6 0.5 5.7 3 3 0.6 4.6 1.5 44 7 43 300 -6.6 0 -6.6 -7 12/13/2005 02:40:00 4.6 0.6 6.1 3 4.5 0.7 6.1 2.6 2.9 0.6 4.6 1.1 40 7 41 300 -7.1 0 -6.8 -7 12/13/2005 02:50:00 4.1 0.6 5.3 2.6 3.7 0.6 5.3 1.9 2.7 0.5 4.6 1.5 35 8 31 300 -6.8 0 -6.6 -7 12/13/2005 03:00:00 3.5 0.5 4.9 2.3 3.1 0.6 4.6 1.5 2.1 0.5 3.8 0.7 30 10 23 300 -7.1 0 -6.8 -7.2 12/13/2005 03:10:00 3.4 0.7 5.3 1.9 3.2 0.6 4.6 1.5 2.1 0.6 4.6 0.7 23 15 29 300 -7.4 0 -7.2 -7.6 12/13/2005 03:20:00 3.4 0.7 4.9 1.1 3.2 0.7 4.9 1.1 1.8 0.7 3.8 0.4 23 16 11 300 -7.6 0 -7.4 -7.6 12/13/2005 03:30:00 3.8 0.6 5.3 2.3 3.5 0.6 5.3 1.9 2.1 0.7 4.6 0.4 24 13 25 300 -7.7 0 -7.6 -7.9 12/13/2005 03:40:00 4.2 0.7 6.1 2.3 3.8 0.7 5.7 1.9 2.1 0.9 4.2 0.4 24 13 22 300 -7.8 0 -7.6 -7.9 12/13/2005 03:50:00 4.3 0.7 5.7 2.6 3.8 0.6 5.7 1.9 2.6 0.6 4.9 1.1 26 10 19 300 -7.7 0 -7.6 -7.9 12/13/2005 04:00:00 4 0.6 6.1 2.3 3.5 0.6 6.1 1.5 2.4 0.7 4.2 0.7 25 10 17 300 -7.9 0 -7.6 -8.1 12/13/2005 04:10:00 3.9 0.8 6.1 1.5 3.5 0.8 5.7 1.1 2.2 0.8 4.9 0.4 25 12 11 300 -7.9 0 -7.6 -8.1 12/13/2005 04:20:00 3.8 0.7 5.7 1.5 3.3 0.7 5.3 1.1 2 0.8 3.8 0.4 24 12 17 300 -7.9 0 -7.6 -7.9 12/13/2005 04:30:00 3.9 0.7 5.7 2.3 3.4 0.7 5.3 1.5 2.2 0.7 4.2 0.4 22 13 18 300 -7.9 0 -7.6 -8.1 12/13/2005 04:40:00 3.3 1 5.3 0.7 3.1 1 5.3 0.7 1.7 0.8 3.8 0.4 16 35 17 300 -7.9 0 -7.6 -8.1 12/13/2005 04:50:00 3.5 0.9 5.7 1.1 3.2 0.9 6.1 0.4 1.8 0.8 3.8 0.4 18 14 15 300 -7.9 0 -7.6 -7.9 12/13/2005 05:00:00 4.4 0.8 6.1 2.3 4.2 1 6.1 1.5 2.7 0.8 5.3 0.7 18 11 16 300 -8 0 -7.6 -8.1 12/13/2005 05:10:00 4.8 0.9 6.8 1.9 4.7 1 6.8 1.5 3.1 1 5.7 0.7 12 12 20 300 -7.8 0 -7.6 -8.1 12/13/2005 05:20:00 4.3 1 6.5 1.9 4.1 1 6.5 1.5 2.8 0.9 4.9 0.7 16 15 16 300 -7.9 0 -7.6 -7.9 12/13/2005 05:30:00 4.5 1.2 6.8 1.9 4.3 1.3 6.8 1.9 3.1 1.1 6.1 1.1 15 12 7 300 -8 0 -7.6 -8.1 12/13/2005 05:40:00 5.5 0.9 7.2 2.6 5.2 1 7.2 2.6 3.9 0.9 6.1 1.5 15 9 19 300 -8 0 -7.9 -8.1 12/13/2005 05:50:00 5.5 0.8 7.2 3.4 5.2 1 7.6 2.6 3.9 0.9 6.8 1.5 17 11 16 300 -7.7 0 -7.6 -7.9 12/13/2005 06:00:00 4.6 0.8 6.5 2.6 4.2 0.9 6.1 1.9 2.9 1 6.1 0.7 17 11 26 300 -7.9 0 -7.6 -7.9 12/13/2005 06:10:00 5 0.7 6.8 3 4.6 0.8 6.5 2.6 3.2 0.9 5.3 0.7 18 10 30 300 -7.9 0 -7.6 -8.1 12/13/2005 06:20:00 5 0.9 6.8 3 4.6 1 7.2 2.3 3.1 1 5.7 0.4 17 12 18 300 -8 0 -7.9 -8.1 12/13/2005 06:30:00 5.4 0.8 7.2 3 5.2 0.9 7.2 3 3.6 0.9 6.1 1.5 14 10 19 300 -7.9 0 -7.6 -8.1 12/13/2005 06:40:00 5.5 0.8 7.6 3.4 5.1 0.9 7.2 2.6 3.6 0.8 6.5 1.5 17 10 14 300 -7.7 0 -7.6 -7.9 12/13/2005 06:50:00 5.2 0.9 7.2 3 4.8 1 7.2 2.6 3.4 1 6.1 1.5 17 11 9 300 -7.6 0 -7.6 -7.6 12/13/2005 07:00:00 5.3 0.8 7.6 3 5.1 1 8 2.3 3.6 0.9 5.7 0.7 14 10 6 300 -7.5 0 -7.4 -7.6 12/13/2005 07:10:00 6 0.8 8 3.8 6 1 8.4 3 4.2 0.9 6.8 1.9 12 9 17 300 -7.4 0 -7.2 -7.6 12/13/2005 07:20:00 5.6 1 7.6 2.3 5.4 1.1 7.6 2.6 4.1 0.9 6.8 2.3 16 9 13 300 -7.3 0 -7.2 -7.4 12/13/2005 07:30:00 5.2 0.6 6.5 3.4 4.5 0.6 5.7 2.6 3.4 0.6 4.9 1.9 23 6 24 300 -7.3 0.1 -7 -7.4 12/13/2005 07:40:00 4.9 0.7 6.5 3 4.2 0.7 6.5 2.6 3.3 0.8 5.7 1.5 24 8 22 300 -7.5 0 -7.2 -7.6 12/13/2005 07:50:00 4.2 0.7 5.7 1.9 3.7 0.7 5.3 1.5 2.7 0.7 4.6 1.1 24 11 17 300 -7.6 0 -7.4 -7.6 12/13/2005 08:00:00 3.9 0.7 5.7 2.3 3.6 0.8 5.7 1.5 2.5 0.8 4.6 0.4 18 12 27 300 -7.5 0 -7.2 -7.6 12/13/2005 08:10:00 3.2 1 5.7 0.4 3 1 5.3 0.4 1.7 0.8 4.2 0.4 12 17 19 300 -7.9 0.1 -7.6 -8.1 12/13/2005 08:20:00 3 0.8 4.9 0.4 2.8 1 5.3 0.4 1.3 0.6 3.4 0.4 14 13 4 300 -8.2 0 -8.1 -8.5 12/13/2005 08:30:00 3.1 0.7 4.9 1.5 2.8 0.8 4.9 1.1 1.6 0.7 4.6 0.4 18 10 26 300 -8.5 0.1 -8.3 -8.7 12/13/2005 08:40:00 4 0.7 6.5 2.6 3.8 0.8 6.1 1.9 2.4 0.7 4.2 0.7 13 7 21 300 -8.9 0 -8.7 -8.9 12/13/2005 08:50:00 4.7 1 7.2 2.3 4.4 1 6.8 1.9 3.2 0.8 5.7 1.5 16 10 15 300 -8.5 0.3 -8.1 -8.9 12/13/2005 09:00:00 6 1 8.4 3.4 5.8 1 8.8 3.4 4.4 1 7.6 1.5 15 9 20 300 -7.7 0.1 -7.6 -8.1 12/13/2005 09:10:00 5.6 1 8 2.6 5.2 1.1 8.4 2.3 3.8 1 6.5 1.1 17 12 13 300 -7.6 0 -7.4 -7.6 12/13/2005 09:20:00 5.2 0.8 7.2 2.6 4.7 0.9 6.8 1.5 3.6 0.8 6.1 1.1 21 9 26 300 -7.6 0 -7.6 -7.6 12/13/2005 09:30:00 4 1.1 6.5 1.1 3.6 1 6.5 0.7 2.5 0.8 4.9 0.7 24 17 13 300 -7.9 0.1 -7.6 -8.1 12/13/2005 09:40:00 3.8 0.7 5.7 1.9 3.4 0.7 5.7 1.9 2.4 0.7 4.2 0.7 31 12 21 300 -8.1 0 -7.9 -8.1 12/13/2005 09:50:00 3.5 0.7 5.3 1.5 3.2 0.7 5.3 1.5 2.2 0.8 4.2 0.4 32 12 36 300 -8.1 0 -7.9 -8.1 12/13/2005 10:00:00 4.3 0.8 6.5 2.6 4 0.8 6.8 1.9 3 0.7 4.9 1.1 35 11 13 300 -7.9 0 -7.6 -7.9 12/13/2005 10:10:00 4.5 0.8 6.8 3 4.1 0.8 6.5 2.3 3.1 0.7 4.6 1.1 34 11 34 300 -7.9 0 -7.6 -7.9 12/13/2005 10:20:00 4.4 0.8 6.5 2.3 4 0.8 6.5 1.9 3 0.8 5.3 1.1 31 11 56 300 -7.6 0 -7.4 -7.9 12/13/2005 10:30:00 4.3 0.8 6.1 2.3 3.8 0.8 6.5 1.9 2.9 0.8 5.3 1.1 27 12 20 300 -7.5 0 -7.2 -7.6 12/13/2005 10:40:00 4.7 0.8 6.5 2.6 4.2 0.8 6.5 2.3 3 0.7 5.7 1.5 23 12 48 300 -7.5 0 -7.2 -7.6 12/13/2005 10:50:00 4.7 0.7 6.5 2.6 4.2 0.7 6.5 2.6 3.1 0.7 5.3 1.9 26 11 24 300 -7.4 0 -7.2 -7.4 12/13/2005 11:00:00 4.8 0.7 6.8 3 4.2 0.7 6.8 2.6 3.3 0.6 4.9 1.5 27 9 38 300 -7.4 0 -7.2 -7.4 12/13/2005 11:10:00 4.6 0.7 6.5 3 4.2 0.7 6.5 2.6 3.3 0.6 5.3 1.9 32 9 35 300 -7.3 0 -7.2 -7.4 12/13/2005 11:20:00 4.8 0.8 6.8 2.3 4.3 0.8 6.5 1.9 3.4 0.8 6.1 1.9 31 9 52 300 -7.2 0 -7 -7.2 12/13/2005 11:30:00 4.3 0.6 6.1 2.6 4.2 0.7 5.7 2.3 2.9 0.8 5.3 1.1 41 9 43 300 -7.1 0 -7 -7 12/13/2005 11:40:00 4.8 0.6 6.5 3 4.4 0.7 5.7 2.6 3.4 0.6 5.3 1.9 35 10 43 300 -7 0 -6.8 -7 12/13/2005 11:50:00 4.6 0.7 6.8 2.6 4.3 0.7 6.1 1.9 3.2 0.7 5.3 1.5 37 9 29 300 -6.8 0 -6.6 -7 12/13/2005 12:00:00 4.7 0.7 6.1 2.6 4.6 0.7 6.5 2.3 3.5 0.7 4.9 1.5 40 8 46 300 -6.6 0 -6.6 -6.8 12/13/2005 12:10:00 4.1 0.7 6.1 1.9 4 0.7 5.7 1.5 2.8 0.7 4.6 0.7 37 9 45 300 -6.4 0 -6.1 -6.6 12/13/2005 12:20:00 4.4 0.6 6.5 2.6 4.2 0.7 6.1 2.3 2.9 0.6 4.6 1.5 38 9 61 300 -6.4 0 -6.1 -6.6 12/13/2005 12:30:00 3.6 0.6 4.9 1.5 3.6 0.7 4.9 1.1 2.5 0.8 4.2 0.4 61 9 65 300 -6.4 0 -6.1 -6.6 12/13/2005 12:40:00 3.3 0.8 5.3 1.9 3.4 0.8 4.9 1.5 2.6 0.7 4.6 0.7 65 11 80 300 -6 0 -5.9 -6.1 12/13/2005 12:50:00 3.3 0.8 4.9 1.1 3.3 0.8 4.9 0.7 2.4 0.9 4.6 0.4 58 13 55 300 -6 0 -5.9 -6.1 12/13/2005 13:00:00 3.6 0.7 5.7 1.9 3.4 0.8 5.7 1.5 2.3 0.8 4.6 0.7 48 15 51 300 -5.8 0 -5.7 -5.9 12/13/2005 13:10:00 2.5 1 5.3 0.4 2.2 1 4.9 0.4 1.8 0.6 3.4 0.4 73 39 40 300 -6.2 0.4 -5.7 -7.4 12/13/2005 13:20:00 1.5 0.5 2.6 0.4 1.3 0.5 2.6 0.4 2.1 0.5 3 0.7 165 26 159 300 -8.2 0.3 -7.2 -8.5 12/13/2005 13:30:00 1.6 0.5 2.6 0.4 1.4 0.6 2.6 0.4 1.5 0.3 2.3 0.7 219 13 217 300 -8.3 0 -8.1 -8.5 12/13/2005 13:40:00 0.8 0.3 1.5 0.4 0.5 0.3 1.1 0.4 0.7 0.4 1.9 0.4 231 7 240 300 -8.1 0 -7.9 -8.1 12/13/2005 13:50:00 1.1 0.5 1.9 0.4 1.1 0.5 1.9 0.4 0.9 0.5 1.9 0.4 201 16 179 300 -7.9 0 -7.9 -8.1 12/13/2005 14:00:00 1 0.8 2.6 0.4 1.2 1 3.8 0.4 1.2 1 3.4 0.4 185 18 196 300 -7.9 0 -7.6 -8.1 12/13/2005 14:10:00 1.9 0.8 4.2 0.4 2 1 4.2 0.4 1.6 0.8 3.4 0.4 210 16 219 300 -7.9 0 -7.6 -7.9 12/13/2005 14:20:00 2.6 0.5 3.8 1.1 2.4 0.5 3.4 0.7 2.4 0.5 3.4 1.1 238 12 234 300 -7.6 0 -7.6 -7.6 12/13/2005 14:30:00 2.6 0.3 3.4 1.5 2.4 0.3 3.4 1.1 2.1 0.4 3 0.7 248 4 245 300 -7.5 0 -7.2 -7.6 12/13/2005 14:40:00 2.4 0.4 3 1.1 2.2 0.4 3 1.1 1.8 0.5 2.6 0.7 236 9 238 300 -7.3 0 -7.2 -7.4 12/13/2005 14:50:00 2.2 0.5 3 0.7 2 0.5 3 0.7 1.7 0.5 2.6 0.4 240 13 228 300 -7.2 0 -7.2 -7.2 12/13/2005 15:00:00 1.9 0.8 3 0.4 1.7 0.7 3 0.4 1.5 0.7 3 0.4 230 8 225 300 -7.2 0 -7.2 -7.4 12/13/2005 15:10:00 1.7 0.7 3 0.4 1.5 0.7 3 0.4 1.5 0.7 3 0.4 246 12 250 300 -7.2 0 -7 -7.2 12/13/2005 15:20:00 3 0.6 4.2 1.5 2.8 0.6 4.2 1.1 2.6 0.7 4.2 1.1 240 9 236 300 -7.3 0 -7.2 -7.4 12/13/2005 15:30:00 2.2 0.5 3.4 1.1 2 0.6 3 0.7 1.9 0.6 3 0.7 257 13 257 300 -7.5 0 -7.2 -7.6 12/13/2005 15:40:00 2.5 0.5 3.4 1.5 2.3 0.5 3.4 1.1 2.4 0.5 3.4 1.1 253 9 254 300 -7.6 0 -7.6 -7.6 12/13/2005 15:50:00 2.7 0.6 3.8 1.5 2.5 0.6 3.8 0.7 2.2 0.6 3.4 0.7 239 10 232 300 -7.6 0 -7.4 -7.6 12/13/2005 16:00:00 2.7 1 4.2 0.4 2.5 1 4.2 0.4 2.1 0.9 3.8 0.4 244 16 241 300 -7.5 0 -7.4 -7.6 12/13/2005 16:10:00 2.7 0.6 4.2 1.1 2.6 0.6 4.2 1.1 2.5 0.6 4.2 0.7 231 16 245 300 -7.5 0 -7.2 -7.4 12/13/2005 16:20:00 2.6 0.5 3.8 1.1 2.5 0.5 3.4 1.5 2.3 0.5 3.4 1.1 222 7 220 300 -7.5 0 -7.2 -7.4 12/13/2005 16:30:00 2.7 0.5 3.8 1.1 2.6 0.5 3.8 1.5 2.3 0.6 3.4 0.7 222 7 223 300 -7.5 0 -7.4 -7.6 12/13/2005 16:40:00 1.6 1 3.4 0.4 1.4 1 3.4 0.4 1.4 1 3.4 0.4 234 17 219 300 -7.5 0 -7.4 -7.6 12/13/2005 16:50:00 1.4 0.7 3.4 0.4 1.3 0.6 3 0.4 1.4 0.5 2.6 0.4 211 10 225 300 -7.5 0 -7.4 -7.6 12/13/2005 17:00:00 2.6 0.6 3.8 0.7 2.4 0.7 3.4 0.4 2.1 0.7 3.4 0.4 236 13 245 300 -7.5 0 -7.4 -7.6 12/13/2005 17:10:00 3.4 0.6 4.9 1.1 3.3 0.6 4.6 1.5 3 0.7 4.6 1.1 224 7 228 300 -7.6 0 -7.4 -7.6 12/13/2005 17:20:00 3.2 0.7 4.9 1.5 3 0.8 4.9 1.1 2.8 0.9 4.6 0.7 236 10 239 300 -7.6 0 -7.4 -7.6 12/13/2005 17:30:00 2.2 0.4 3.4 1.1 2 0.4 3 0.7 1.8 0.5 3.4 0.7 249 8 242 300 -7.6 0 -7.6 -7.6 12/13/2005 17:40:00 3.1 0.6 4.6 1.5 2.9 0.6 4.2 1.1 2.7 0.6 4.2 1.5 232 10 229 300 -7.6 0 -7.4 -7.6 12/13/2005 17:50:00 2.2 0.8 3.8 0.4 2 0.8 3.4 0.4 1.8 0.8 3.8 0.4 225 12 237 300 -7.6 0 -7.6 -7.6 12/13/2005 18:00:00 2.1 0.5 3.4 0.7 1.9 0.5 3 0.7 1.8 0.5 3 0.7 225 12 234 300 -7.6 0 -7.6 -7.6 12/13/2005 18:10:00 1.8 0.6 2.6 0.4 1.5 0.6 2.6 0.4 1.5 0.6 2.6 0.4 229 12 234 300 -7.6 0 -7.6 -7.6 12/13/2005 18:20:00 2.1 0.5 3.4 0.4 1.9 0.5 3 0.4 1.9 0.5 3 0.4 226 10 233 300 -7.6 0 -7.6 -7.6 12/13/2005 18:30:00 2 0.5 3.4 0.4 1.9 0.5 3 0.4 1.8 0.5 3 0.7 221 8 219 300 -7.6 0 -7.6 -7.6 12/13/2005 18:40:00 1.4 0.8 3 0.4 1.2 0.8 2.6 0.4 1.1 0.7 2.6 0.4 232 12 219 300 -7.7 0 -7.6 -7.9 12/13/2005 18:50:00 1.6 0.5 2.6 0.4 1.2 0.5 2.3 0.4 1.1 0.5 2.3 0.4 247 15 251 300 -7.7 0 -7.6 -7.9 12/13/2005 19:00:00 1.4 0.4 2.3 0.4 1.1 0.4 1.9 0.4 1.1 0.4 2.3 0.4 225 8 219 300 -7.7 0 -7.6 -7.6 12/13/2005 19:10:00 1.2 0.7 2.6 0.4 1 0.6 2.6 0.4 1 0.6 2.6 0.4 218 17 222 300 -7.7 0 -7.6 -7.9 12/13/2005 19:20:00 0.8 0.6 2.3 0.4 0.7 0.5 2.3 0.4 0.7 0.4 1.9 0.4 222 18 228 300 -7.8 0 -7.6 -7.9 12/13/2005 19:30:00 1 0.3 1.9 0.4 0.6 0.3 1.5 0.4 0.8 0.3 1.5 0.4 186 8 190 300 -7.9 0 -7.6 -7.9 12/13/2005 19:40:00 1 0.4 1.9 0.4 0.7 0.4 1.5 0.4 1 0.4 1.9 0.4 169 12 194 300 -7.9 0 -7.6 -7.9 12/13/2005 19:50:00 0.6 0.4 1.9 0.4 0.5 0.3 1.5 0.4 0.5 0.3 1.9 0.4 183 5 194 300 -7.9 0 -7.6 -8.1 12/13/2005 20:00:00 0.8 0.3 1.5 0.4 0.5 0.3 1.5 0.4 0.8 0.4 1.5 0.4 188 14 181 300 -7.9 0 -7.6 -8.1 12/13/2005 20:10:00 0.7 0.4 1.9 0.4 0.7 0.4 1.9 0.4 0.8 0.4 1.9 0.4 204 8 193 300 -7.9 0 -7.6 -8.1 12/13/2005 20:20:00 1.1 0.5 1.9 0.4 1.1 0.6 1.9 0.4 1.1 0.6 2.3 0.4 197 8 193 300 -7.9 0 -7.6 -7.9 12/13/2005 20:30:00 0.8 0.4 1.9 0.4 0.6 0.3 1.5 0.4 0.7 0.4 1.5 0.4 205 21 185 300 -7.9 0 -7.9 -8.1 12/13/2005 20:40:00 1.5 0.5 2.6 0.4 1.2 0.5 2.3 0.4 1.3 0.4 1.9 0.4 221 9 232 300 -7.9 0 -7.9 -8.1 12/13/2005 20:50:00 1.3 0.4 2.3 0.4 1.2 0.4 2.3 0.4 1.2 0.4 2.3 0.4 214 10 219 300 -8 0 -7.9 -8.1 12/13/2005 21:00:00 1 0.5 2.3 0.4 0.8 0.5 1.9 0.4 0.8 0.6 2.3 0.4 213 7 222 300 -8 0 -7.9 -8.1 12/13/2005 21:10:00 1.2 0.7 2.6 0.4 1 0.6 2.3 0.4 1.1 0.7 2.3 0.4 210 15 215 300 -8.1 0 -8.1 -8.1 12/13/2005 21:20:00 2 0.5 3 0.7 1.9 0.5 3 0.7 1.7 0.6 3 0.7 225 11 226 300 -8.2 0 -8.1 -8.3 12/13/2005 21:30:00 2.1 0.4 3 1.5 1.9 0.4 3 1.1 1.4 0.6 2.6 0.4 241 12 254 300 -8.2 0 -8.1 -8.3 12/13/2005 21:40:00 1.8 0.5 2.6 0.7 1.6 0.5 2.6 0.4 1.5 0.5 2.6 0.4 231 15 268 300 -8.2 0 -8.1 -8.3 12/13/2005 21:50:00 1.6 0.6 2.6 0.4 1.4 0.6 2.6 0.4 1.4 0.6 2.3 0.4 230 14 226 300 -8.3 0 -8.1 -8.5 12/13/2005 22:00:00 1 0.7 2.6 0.4 0.8 0.6 2.3 0.4 0.7 0.5 1.9 0.4 227 12 236 300 -8.4 0 -8.3 -8.7 12/13/2005 22:10:00 2.3 0.6 3.8 0.7 2.3 0.5 3.4 1.1 2 0.6 3.4 0.7 219 6 224 300 -8.6 0 -8.5 -8.7 12/13/2005 22:20:00 3.5 0.6 4.9 2.3 3.3 0.6 4.6 2.3 2.9 0.6 4.2 1.1 240 9 237 300 -8.6 0.1 -8.3 -8.7 12/13/2005 22:30:00 3.1 0.5 4.2 1.5 2.9 0.5 3.8 1.5 2.7 0.5 3.4 1.1 252 6 254 300 -8.2 0 -8.1 -8.3 12/13/2005 22:40:00 2.4 0.4 3.4 1.1 2.2 0.5 3.4 0.7 1.8 0.5 3 0.7 252 9 253 300 -8.2 0 -8.1 -8.1 12/13/2005 22:50:00 2 0.7 3 0.4 1.7 0.7 3 0.4 1.6 0.8 3 0.4 233 15 222 300 -8.1 0 -8.1 -8.1 12/13/2005 23:00:00 2.1 0.4 3.4 1.1 1.9 0.5 3.4 0.7 1.8 0.4 3 0.7 246 19 248 300 -8.2 0 -8.1 -8.3 12/13/2005 23:10:00 2 0.5 3 0.7 1.7 0.6 3 0.4 1.7 0.6 3 0.4 252 9 256 300 -8.4 0 -8.1 -8.5 12/13/2005 23:20:00 2.4 0.5 3.4 1.1 2.1 0.5 3 1.1 2 0.5 3 1.1 250 10 254 300 -8.2 0 -8.1 -8.5 12/13/2005 23:30:00 2 0.3 2.6 0.7 1.7 0.4 2.6 0.4 1.8 0.3 2.3 0.7 271 10 274 300 -8.2 0 -8.1 -8.3 12/13/2005 23:40:00 2.9 0.4 3.8 2.3 2.7 0.4 3.4 1.9 2.8 0.4 3.8 1.9 250 7 245 300 -8.2 0 -8.1 -8.3 12/13/2005 23:50:00 2.6 0.4 3.4 1.5 2.4 0.5 3.4 1.1 2.4 0.5 3.4 1.1 250 13 248 300 -8.2 0 -8.1 -8.3 12/14/2005 00:00:00 2.8 0.5 4.2 1.5 2.6 0.5 4.2 1.1 2.6 0.4 3.8 1.5 240 9 241 300 -8.2 0 -8.1 -8.3 12/14/2005 00:10:00 2.2 0.7 4.2 0.4 2 0.8 3.8 0.4 1.8 0.7 3.4 0.4 240 27 217 300 -8.2 0 -8.1 -8.1 12/14/2005 00:20:00 1.9 0.5 2.6 0.4 1.6 0.6 2.6 0.4 2 0.6 3.4 0.4 249 22 275 300 -8.2 0 -8.1 -8.3 12/14/2005 00:30:00 2.3 0.4 3 0.7 2.1 0.5 3 0.4 1.9 0.6 2.6 0.4 249 7 247 300 -8.2 0 -8.1 -8.1 12/14/2005 00:40:00 1.5 0.4 2.3 0.4 1.2 0.5 2.3 0.4 1.2 0.5 2.3 0.4 228 20 242 300 -8.1 0 -8.1 -8.1 12/14/2005 00:50:00 1.8 0.5 3 0.7 1.5 0.5 2.6 0.4 1.4 0.6 3 0.4 230 13 234 300 -8 0 -7.9 -8.1 12/14/2005 01:00:00 2.3 0.4 3.4 1.5 2 0.4 3 1.1 1.8 0.4 2.6 1.1 258 8 257 300 -7.9 0 -7.6 -8.1 12/14/2005 01:10:00 1.3 0.6 2.3 0.4 0.9 0.5 2.3 0.4 1.1 0.4 1.9 0.4 281 45 301 300 -7.6 0 -7.6 -7.6 12/14/2005 01:20:00 1.3 0.6 2.6 0.4 1.1 0.6 1.9 0.4 1.5 0.5 2.3 0.4 192 26 179 300 -7.6 0 -7.6 -7.6 12/14/2005 01:30:00 0.8 0.5 2.3 0.4 0.5 0.4 1.9 0.4 0.9 0.4 1.9 0.4 141 35 97 300 -7.6 0 -7.4 -7.6 12/14/2005 01:40:00 0.7 0.4 1.5 0.4 0.5 0.2 1.5 0.4 1 0.6 2.3 0.4 156 39 158 300 -7.5 0 -7.4 -7.6 12/14/2005 01:50:00 0.7 0.4 1.5 0.4 0.4 0.2 1.5 0.4 1 0.5 2.3 0.4 174 61 185 300 -7.5 0 -7.2 -7.6 12/14/2005 02:00:00 1 0.8 3 0.4 0.9 0.8 3 0.4 0.7 0.4 1.9 0.4 296 94 51 300 -7.4 0 -7.2 -7.4 12/14/2005 02:10:00 1.3 0.6 3 0.4 1.1 0.6 3 0.4 1.5 0.5 2.6 0.4 137 39 125 300 -7.3 0 -7.2 -7.4 12/14/2005 02:20:00 1.3 0.8 3.8 0.4 1.1 0.8 4.2 0.4 1 0.8 2.6 0.4 75 51 49 300 -7.3 0 -7 -7.4 12/14/2005 02:30:00 1.6 0.8 3.8 0.4 1.4 0.9 4.2 0.4 1.1 0.6 3 0.4 98 33 80 300 -7.2 0 -7 -7.2 12/14/2005 02:40:00 1.3 0.5 2.6 0.4 1.1 0.6 2.6 0.4 1.4 0.4 2.3 0.7 136 27 91 300 -7.3 0 -7.2 -7.4 12/14/2005 02:50:00 1.1 0.6 3 0.4 0.9 0.6 3 0.4 0.6 0.4 1.9 0.4 97 22 81 300 -7.3 0 -7.2 -7.4 12/14/2005 03:00:00 1.3 0.6 3 0.4 1 0.6 2.6 0.4 1.1 0.5 2.3 0.4 106 22 109 300 -7.2 0 -7 -7.4 12/14/2005 03:10:00 1.8 1.2 5.7 0.4 1.6 1.2 5.7 0.4 1.1 0.9 3.4 0.4 84 35 31 300 -7.1 0.1 -6.8 -7.2 12/14/2005 03:20:00 1.6 0.7 3.4 0.4 1.4 0.8 3.4 0.4 1.8 0.5 3 0.4 134 38 72 300 -7 0 -6.8 -7 12/14/2005 03:30:00 1.6 1 5.7 0.4 1.5 1 5.3 0.4 1.4 0.7 3.4 0.4 117 29 48 300 -7.1 0 -6.8 -7 12/14/2005 03:40:00 2.6 1 5.3 0.7 2.5 1 5.7 0.4 1.9 0.9 4.9 0.4 64 26 56 300 -6.8 0.2 -6.6 -7 12/14/2005 03:50:00 2.9 1 5.3 0.4 2.7 1 5.3 0.4 2 0.8 4.2 0.4 61 22 61 300 -6.5 0 -6.1 -6.6 12/14/2005 04:00:00 2.1 1.1 6.8 0.4 2 1.2 6.5 0.4 2.1 0.8 5.3 0.4 117 41 100 300 -6.2 0.1 -5.9 -6.6 12/14/2005 04:10:00 1.7 0.5 3 0.4 1.7 0.5 3.4 0.4 1.4 0.7 2.6 0.4 104 33 108 300 -6.5 0 -6.4 -6.6 12/14/2005 04:20:00 2.6 0.5 3.4 1.5 2.6 0.5 3.4 1.5 2 0.5 3.4 0.7 106 17 91 300 -6.2 0 -5.9 -6.6 12/14/2005 04:30:00 1.5 0.7 3.4 0.4 1.5 0.7 3.4 0.4 1.4 0.6 3 0.4 120 29 100 300 -6 0 -5.9 -6.1 12/14/2005 04:40:00 1.4 0.5 2.6 0.4 1.3 0.4 2.3 0.4 1.4 0.5 2.6 0.4 145 43 181 300 -6.4 0.1 -6.1 -6.6 12/14/2005 04:50:00 2.5 0.8 4.6 0.7 2.4 0.8 4.6 0.7 1.8 0.6 3.8 0.7 65 19 63 300 -6.2 0.1 -6.1 -6.6 12/14/2005 05:00:00 2 0.9 4.9 0.4 2 1 4.6 0.4 2 0.9 4.9 0.4 99 38 34 300 -6.2 0 -5.9 -6.4 12/14/2005 05:10:00 2.3 1 5.3 0.4 2.3 0.8 4.6 0.4 1.9 0.7 3.8 0.4 93 38 28 300 -6.4 0.1 -5.9 -6.6 12/14/2005 05:20:00 6.4 2.4 11.8 1.9 5.9 2.2 11.1 1.9 5.1 2.1 11.1 1.5 39 21 25 300 -4.3 1.2 -2.6 -6.4 12/14/2005 05:30:00 5.7 2.3 13 1.9 5.4 2.1 12.6 0.7 4.5 1.8 10.7 1.1 71 53 33 300 -3.2 0.8 -2.6 -5.5 12/14/2005 05:40:00 2.9 0.9 5.3 0.4 2.8 0.9 4.9 0.4 2.9 0.8 4.9 1.1 157 29 169 300 -6.4 0.2 -5.5 -6.6 12/14/2005 05:50:00 1.6 1 4.2 0.4 1.5 1 4.2 0.4 1.9 0.9 4.6 0.4 179 28 181 300 -6.4 0 -6.1 -6.6 12/14/2005 06:00:00 2.4 1.3 6.5 0.4 2.1 1.3 6.5 0.4 2.1 1 5.3 0.4 115 102 103 300 -5.7 0.6 -4.4 -6.4 12/14/2005 06:10:00 2.7 1.1 6.1 0.4 2.5 1.2 5.7 0.4 2.5 1.1 6.8 0.4 114 53 103 300 -5.4 0.6 -4.4 -5.9 12/14/2005 06:20:00 2.1 1.2 6.8 0.4 1.9 1.3 8 0.4 1.7 0.8 4.6 0.4 123 51 345 300 -5.7 0.3 -4.8 -5.9 12/14/2005 06:30:00 6.8 2.3 14.1 1.1 6.4 2.1 13.7 1.5 5.4 1.9 11.8 1.1 37 27 26 300 -3.3 0.9 -2.4 -5 12/14/2005 06:40:00 4.9 2.2 12.6 1.1 4.7 2.1 11.5 0.4 4.1 1.8 9.5 0.4 54 39 31 300 -2.8 0.3 -2.1 -3.3 12/14/2005 06:50:00 7.7 1.8 13.3 2.6 7.3 1.8 12.2 2.6 6.2 1.5 11.1 2.6 38 19 21 300 -2.6 0.2 -2.4 -3 12/14/2005 07:00:00 4.9 1.9 11.5 0.7 4.8 1.8 10.7 0.4 4.2 1.6 9.1 0.7 59 41 71 300 -2.6 0.1 -2.4 -3.3 12/14/2005 07:10:00 4.2 1.5 8.8 0.7 4.2 1.5 8.4 1.1 3.8 1.1 6.5 1.1 58 38 48 300 -3.2 0.1 -2.8 -3.5 12/14/2005 07:20:00 6.7 1.8 12.2 1.5 6.4 1.7 12.2 2.6 5.1 1.7 10.3 1.1 41 22 67 300 -2.4 0.2 -2.1 -2.8 12/14/2005 07:30:00 7.6 2.4 13.3 1.9 7.1 2.2 13 1.1 5.6 1.8 10.7 1.5 35 27 17 300 -2.1 0 -2.1 -2.1 12/14/2005 07:40:00 10.6 1.9 16.8 5.7 9.7 1.8 14.1 5.7 8.1 1.7 13 3.8 25 13 35 300 -2.1 0 -2.1 -2.1 12/14/2005 07:50:00 10.9 2.1 16.1 3 9.9 1.9 15.3 2.3 8.3 2 13.7 2.3 27 14 47 300 -2.2 0 -2.1 -2.4 12/14/2005 08:00:00 10.6 2.1 15.3 5.3 9.6 1.9 14.1 3.8 8.1 1.9 13.3 1.5 27 13 18 300 -2.4 0 -2.1 -2.4 12/14/2005 08:10:00 8.2 2.7 13.7 1.5 7.6 2.5 13 2.3 6.2 2.1 12.2 1.9 31 24 26 300 -2.2 0 -2.1 -2.4 12/14/2005 08:20:00 8.6 1.9 14.5 4.2 7.9 1.8 14.1 4.2 6.7 1.8 11.8 1.5 30 17 27 300 -2.1 0 -1.9 -2.1 12/14/2005 08:30:00 9.2 1.8 13.7 4.2 8.5 1.8 13 4.2 7 1.7 12.2 2.6 29 14 35 300 -2.1 0 -2.1 -2.1 12/14/2005 08:40:00 8 2.1 12.6 1.9 7.4 2 12.2 0.7 6.2 1.9 11.1 1.5 35 20 19 300 -2.2 0 -2.1 -2.6 12/14/2005 08:50:00 7.4 2.5 12.6 1.9 6.9 2.3 12.2 1.9 5.7 2.1 12.6 0.7 33 22 30 300 -2.4 0 -2.1 -2.6 12/14/2005 09:00:00 7.5 2.4 13.3 2.3 7 2.2 12.6 2.6 6 2.1 11.8 1.1 35 23 34 300 -2.3 0 -2.1 -2.6 12/14/2005 09:10:00 7.6 2.7 15.3 2.3 7 2.5 15.3 2.3 5.9 2.3 13 0.7 39 28 40 300 -2.2 0 -2.1 -2.4 12/14/2005 09:20:00 6.3 1.9 11.8 2.3 6.1 1.8 11.5 2.3 5.3 1.7 10.3 1.5 43 23 31 300 -2.3 0 -2.1 -2.4 12/14/2005 09:30:00 8.8 2.1 13.7 3 8.1 1.8 12.2 2.6 6.8 2 11.8 1.1 29 16 26 300 -2.1 0 -2.1 -2.1 12/14/2005 09:40:00 9.6 2.2 14.9 4.6 8.8 2.2 14.1 3.4 7.3 2.1 13 2.3 27 16 24 300 -2.2 0 -2.1 -2.4 12/14/2005 09:50:00 10 2.2 14.5 4.9 9.2 2 14.1 4.2 7.6 1.8 12.6 4.2 29 16 27 300 -2.2 0 -2.1 -2.1 12/14/2005 10:00:00 11.5 2.1 16.4 5.3 10.4 1.9 14.9 4.9 9 2 14.9 4.2 26 12 15 300 -2.1 0 -1.9 -2.1 12/14/2005 10:10:00 12.4 2.1 18.3 4.6 11.2 2.1 16.8 4.2 9.7 2 15.3 4.9 23 12 11 300 -2.1 0 -1.9 -2.1 12/14/2005 10:20:00 12 1.7 16.8 7.2 10.9 1.6 16.8 6.1 9.5 1.7 14.1 4.6 23 11 9 300 -2 0 -1.9 -2.1 12/14/2005 10:30:00 11.4 1.9 17.2 6.8 10.4 1.7 14.5 5.7 8.6 1.9 15.6 4.2 25 13 39 300 -1.8 0 -1.7 -1.9 12/14/2005 10:40:00 10.7 2 15.6 5.7 9.7 1.9 15.3 5.3 8.1 1.8 13 3 27 13 35 300 -1.8 0 -1.7 -1.9 12/14/2005 10:50:00 11.3 2.1 16.8 5.7 10.2 2 14.9 4.9 8.6 1.7 13.3 4.2 27 12 34 300 -1.4 0.1 -1.2 -1.7 12/14/2005 11:00:00 10.6 2 15.6 5.7 9.7 2 16.1 4.9 8.2 1.7 14.9 4.2 28 13 21 300 -1.4 0 -1.2 -1.4 12/14/2005 11:10:00 11.1 1.7 16.4 5.3 10.1 1.7 14.1 4.9 8.6 1.5 13 4.2 28 13 28 300 -1.3 0 -1.2 -1.4 12/14/2005 11:20:00 10.9 2.1 16.4 6.1 9.9 1.9 14.5 5.3 8.5 2 14.5 4.2 30 13 20 300 -1 0 -0.7 -1.2 12/14/2005 11:30:00 11 2.1 16.4 5.7 10 2 16.1 6.1 8.6 1.7 13.3 4.9 29 12 30 300 -1 0 -0.7 -1.2 12/14/2005 11:40:00 12.4 2 16.8 5.7 11.3 2 16.1 4.9 9.7 2 15.6 4.6 26 11 20 300 -1 0 -1 -1.2 12/14/2005 11:50:00 11.8 2.2 17.2 5.7 10.7 2.1 16.8 4.9 8.8 2.1 14.9 3.4 27 14 8 300 -1.1 0 -1 -1.2 12/14/2005 12:00:00 11.7 2.4 17.6 5.7 10.7 2.3 17.9 5.3 8.9 2.2 15.6 3.8 24 14 9 300 -1.1 0 -1 -1.2 12/14/2005 12:10:00 11.5 2.2 17.9 5.3 10.5 2.2 17.6 4.6 9.1 2.2 17.9 4.2 22 13 10 300 -1.3 0 -1.2 -1.4 12/14/2005 12:20:00 11.6 2 17.2 6.1 10.5 2 16.8 4.9 9 2 14.5 4.2 24 12 31 300 -1.5 0 -1.2 -1.4 12/14/2005 12:30:00 12.5 2 17.9 6.5 11.3 1.9 16.4 5.7 9.9 1.9 15.3 4.9 24 12 34 300 -1.6 0 -1.4 -1.9 12/14/2005 12:40:00 11.6 2.2 17.6 7.2 10.5 2 16.4 5.3 9.1 2 14.9 4.6 24 12 18 300 -1.7 0 -1.4 -1.9 12/14/2005 12:50:00 10.6 2 15.3 4.9 9.6 2 14.9 4.6 8 2 13 2.3 23 12 22 300 -1.6 0 -1.4 -1.7 12/14/2005 13:00:00 11 2.4 16.8 4.6 10 2.3 16.1 3.8 8.5 2 16.4 3.8 24 12 34 300 -1.4 0 -1.2 -1.4 12/14/2005 13:10:00 12.4 2.2 17.9 6.5 11.2 2.1 17.6 5.7 9.6 1.8 14.5 4.6 27 11 14 300 -1.6 0 -1.4 -1.7 12/14/2005 13:20:00 12.4 2.2 17.9 6.1 11.3 2.1 16.4 5.7 9.5 2 14.9 4.6 26 12 30 300 -1.6 0 -1.4 -1.7 12/14/2005 13:30:00 12.2 1.9 17.6 8 11.2 1.9 16.1 6.8 9.4 2.1 15.6 4.6 24 12 30 300 -1.9 0.1 -1.7 -2.1 12/14/2005 13:40:00 12 2.1 16.4 6.1 10.9 2 15.3 5.7 9.6 2.2 14.1 3.4 24 11 4 300 -2 0.1 -1.9 -2.1 12/14/2005 13:50:00 11.8 2.2 16.8 5.3 10.7 2.1 16.1 5.3 9.2 1.8 14.5 4.2 21 13 17 300 -2.1 0 -1.9 -2.4 12/14/2005 14:00:00 11.7 2.3 17.6 4.9 10.7 2.1 16.4 3.8 9.5 1.9 15.6 4.6 23 13 27 300 -2.1 0 -2.1 -2.1 12/14/2005 14:10:00 12.4 2.1 17.6 6.8 11.3 1.9 17.2 6.1 9.6 2.1 14.9 4.9 23 11 25 300 -2.1 0 -2.1 -2.1 12/14/2005 14:20:00 12.6 2.2 17.9 4.9 11.6 2.2 17.9 4.6 9.9 2.2 15.3 5.3 22 12 8 300 -2.1 0 -2.1 -2.1 12/14/2005 14:30:00 12.7 2.6 20.6 5.3 11.6 2.5 18.7 4.2 10 2.3 16.8 3.8 24 12 24 300 -2 0 -1.9 -2.1 12/14/2005 14:40:00 13.1 2.2 17.9 6.8 11.9 2 17.2 5.7 10.2 1.9 14.9 5.7 22 12 17 300 -1.8 0 -1.4 -1.9 12/14/2005 14:50:00 12 2 17.2 6.8 10.8 1.7 15.6 6.5 9.2 1.8 14.1 4.6 24 13 25 300 -1.7 0 -1.4 -1.9 12/14/2005 15:00:00 12.4 2 17.2 6.1 11.3 1.9 16.4 5.3 9.4 2 15.3 4.6 23 11 27 300 -1.8 0 -1.7 -1.9 12/14/2005 15:10:00 11.7 1.8 16.4 6.8 10.8 1.7 15.6 6.1 9 1.9 14.5 4.2 21 11 14 300 -1.7 0 -1.4 -1.9 12/14/2005 15:20:00 11.7 1.7 16.1 7.6 10.7 1.7 16.1 6.8 9 1.9 15.6 3.8 21 12 11 300 -1.6 0 -1.4 -1.7 12/14/2005 15:30:00 11.6 2.1 16.1 6.5 10.7 2.2 16.4 5.7 9.1 2 14.9 3 19 11 26 300 -1.5 0 -1.2 -1.4 12/14/2005 15:40:00 11.8 1.9 17.2 6.5 10.9 1.9 16.1 6.1 9.1 1.8 14.1 4.2 18 11 27 300 -1.5 0 -1.2 -1.7 12/14/2005 15:50:00 11.5 2 16.4 5.7 10.4 2 16.4 4.2 9 1.8 14.9 4.9 24 12 41 300 -1.4 0.1 -1.2 -1.7 12/14/2005 16:00:00 12.1 2 16.8 7.2 11 1.9 16.1 5.3 9.4 1.9 14.5 4.2 23 11 30 300 -1.2 0 -1.2 -1.4 12/14/2005 16:10:00 12 1.8 16.8 7.6 11 1.9 16.4 6.1 9.6 2 16.4 4.6 21 12 17 300 -1.3 0 -1.2 -1.4 12/14/2005 16:20:00 12 1.9 16.1 7.2 11 2 16.1 6.1 9.5 2.1 15.3 4.2 19 10 18 300 -1.2 0 -1 -1.2 12/14/2005 16:30:00 12.4 1.9 17.2 7.6 11.4 2 16.4 5.7 9.9 2.2 16.8 3.8 20 10 20 300 -1.3 0 -1 -1.4 12/14/2005 16:40:00 11.9 1.9 17.2 6.8 10.7 1.8 15.3 6.5 9.1 1.7 13.7 4.9 22 11 26 300 -1.4 0 -1.2 -1.4 12/14/2005 16:50:00 10.7 1.8 14.9 6.1 9.8 1.9 14.9 5.3 8.4 1.8 14.5 4.9 20 12 13 300 -1.4 0.1 -1.2 -1.4 12/14/2005 17:00:00 10.7 1.9 15.6 6.1 9.8 1.7 13.7 4.9 8.3 1.8 13.3 4.2 21 13 25 300 -1.1 0 -1 -1.2 12/14/2005 17:10:00 11.4 1.9 16.1 6.5 10.3 1.7 14.9 5.7 9 1.7 15.3 4.9 25 12 43 300 -1 0 -0.7 -1.2 12/14/2005 17:20:00 12.6 2 17.6 6.1 11.4 1.8 16.8 5.3 9.6 2 15.3 4.9 26 12 22 300 -0.9 0 -0.7 -1 12/14/2005 17:30:00 12.2 2 16.8 6.5 11 1.9 15.3 6.1 9.4 2 14.5 4.2 25 13 27 300 -1 0 -0.7 -1 12/14/2005 17:40:00 12 2 16.1 6.8 10.8 1.8 15.6 6.5 9.2 1.7 13.7 4.9 27 12 35 300 -1 0 -1 -1.2 12/14/2005 17:50:00 12.3 2.1 17.2 6.8 11.2 1.9 16.1 5.7 9.4 1.8 14.1 5.3 25 12 18 300 -0.9 0.1 -0.5 -1 12/14/2005 18:00:00 12.2 2.1 17.2 7.6 11.1 1.8 16.8 6.1 9.4 1.9 15.3 3.8 22 12 25 300 -0.6 0 -0.5 -0.7 12/14/2005 18:10:00 12.5 2.1 17.6 6.8 11.3 1.9 16.4 6.1 9.6 2.1 14.9 4.6 28 12 32 300 -0.4 0 -0.3 -0.5 12/14/2005 18:20:00 11.9 2 16.4 6.5 10.9 1.9 15.6 6.1 9.2 1.9 14.9 4.2 29 13 27 300 -0.4 0 -0.3 -0.5 12/14/2005 18:30:00 11.2 2.1 16.4 5.7 10.2 2 16.1 4.9 8.7 1.9 13.7 3.8 30 11 34 300 -0.2 0 -0.1 -0.5 12/14/2005 18:40:00 11.3 2.1 15.6 6.1 10.2 1.8 14.5 4.6 8.6 1.9 14.1 4.2 28 11 27 300 -0.1 0 -0.1 -0.3 12/14/2005 18:50:00 10.3 1.9 15.3 6.1 9.4 1.7 14.1 5.3 8 1.7 12.6 3.4 29 13 28 300 0 0 0.2 -0.1 12/14/2005 19:00:00 11.1 1.9 15.6 5.7 10.2 1.7 14.9 5.3 8.6 1.8 13.3 4.2 28 13 43 300 0.2 0 0.4 0.2 12/14/2005 19:10:00 11.8 2 16.4 6.5 11.1 2 16.1 6.1 9.2 1.7 14.1 4.6 34 10 39 300 0.4 0 0.7 0.2 12/14/2005 19:20:00 11.6 1.7 16.1 6.5 10.9 1.8 14.9 5.7 9 1.8 14.9 3 34 12 25 300 0.4 0 0.7 0.2 12/14/2005 19:30:00 11.8 1.8 15.6 3.4 10.6 1.7 15.6 3.8 9.2 1.7 14.1 4.6 28 10 35 300 0.4 0 0.7 0.2 12/14/2005 19:40:00 10.6 1.7 14.1 6.1 9.6 1.7 13.7 4.6 8 1.7 13 3 30 11 24 300 0.4 0 0.7 0.2 12/14/2005 19:50:00 10.5 1.8 14.9 5.7 9.5 1.7 14.1 4.6 7.9 1.8 13.3 3.8 28 13 38 300 0.2 0 0.4 0.2 12/14/2005 20:00:00 10.1 1.5 13.7 6.5 9.1 1.5 13 5.3 7.7 1.4 11.5 3.4 24 12 24 300 0.1 0 0.2 -0.1 12/14/2005 20:10:00 10.4 1.8 14.1 5.7 9.4 1.7 13.7 4.6 8 1.7 14.1 3 26 12 31 300 0.1 0 0.2 -0.1 12/14/2005 20:20:00 10.7 1.7 15.3 6.1 9.6 1.7 14.9 4.9 8.2 1.8 14.1 3 27 12 32 300 -0.2 0.1 0.2 -0.5 12/14/2005 20:30:00 10.1 1.6 13.7 6.1 9.2 1.5 13.3 5.3 7.8 1.6 11.5 4.2 28 12 22 300 -0.2 0 -0.1 -0.3 12/14/2005 20:40:00 10.6 1.7 14.1 5.7 9.5 1.6 13.7 5.3 8 1.7 13 3.4 23 11 22 300 -0.2 0 -0.1 -0.3 12/14/2005 20:50:00 12 1.9 16.4 5.3 10.7 1.7 14.9 4.6 9.1 1.8 14.1 5.3 24 11 16 300 -0.3 0 -0.1 -0.3 12/14/2005 21:00:00 11.8 2 17.2 5.3 10.8 1.9 14.9 5.3 9.1 2 14.5 4.6 21 12 22 300 -0.3 0 -0.1 -0.5 12/14/2005 21:10:00 12.2 2 17.2 6.5 11.2 2 17.2 5.7 9.6 2 14.9 4.9 20 11 26 300 -0.3 0 -0.1 -0.5 12/14/2005 21:20:00 11.8 1.8 16.1 6.1 10.7 1.8 16.4 4.9 9.1 1.9 13.7 4.6 22 12 12 300 -0.3 0 -0.1 -0.5 12/14/2005 21:30:00 11.1 1.8 16.1 6.5 10.2 1.7 15.6 5.3 8.5 1.9 14.5 4.2 23 13 17 300 0 0 0.2 -0.1 12/14/2005 21:40:00 11 1.9 15.6 5.3 9.9 1.9 16.4 4.9 8.4 1.7 13.3 3.8 24 11 10 300 0.2 0.1 0.4 -0.1 12/14/2005 21:50:00 11.3 1.9 16.1 6.1 10.1 1.8 14.9 5.3 8.5 1.6 13 4.6 24 12 28 300 0.4 0 0.7 0.4 12/14/2005 22:00:00 11.1 1.9 16.1 6.5 10.1 1.7 15.3 5.3 8.5 1.7 13.7 3.8 24 12 28 300 0.4 0 0.7 0.2 12/14/2005 22:10:00 11.4 1.9 17.2 6.5 10.3 1.8 17.2 5.3 9.1 1.7 14.1 4.2 26 13 13 300 0.4 0 0.7 0.2 12/14/2005 22:20:00 11.4 1.8 16.4 6.5 10.3 1.7 15.6 6.1 8.8 1.9 14.5 3.8 26 12 16 300 0.4 0 0.7 0.2 12/14/2005 22:30:00 10.7 1.8 15.3 5.7 9.7 1.8 15.3 5.3 8.3 1.7 12.2 3.4 23 12 11 300 0.5 0 0.7 0.4 12/14/2005 22:40:00 10.9 1.9 16.1 6.5 9.9 1.7 15.3 4.9 8.3 1.7 13.3 3.8 22 12 43 300 0.5 0 0.7 0.7 12/14/2005 22:50:00 9.7 1.7 14.9 4.6 9.1 1.9 15.6 4.2 7.5 2 13.3 2.6 18 15 25 300 0.5 0 0.7 0.4 12/14/2005 23:00:00 9.5 1.7 13.3 4.9 8.8 1.8 13.3 4.6 7.5 1.7 12.2 2.6 20 14 16 300 0.7 0 0.7 0.7 12/14/2005 23:10:00 9.7 1.9 14.5 4.9 8.9 2 15.3 4.2 7.5 1.8 12.6 4.2 20 13 16 300 0.7 0 0.9 0.7 12/14/2005 23:20:00 9.6 1.7 14.5 5.3 9.1 1.8 14.5 4.6 7.6 1.8 12.6 1.1 18 12 40 300 0.8 0 1.1 0.7 12/14/2005 23:30:00 9.2 2.1 14.1 2.3 8.4 2 13.7 2.3 7.1 1.9 13 2.3 22 13 28 300 1 0 1.1 0.9 12/14/2005 23:40:00 9.1 1.9 13.7 3.8 8.4 1.8 13.3 3 7.1 1.7 12.2 3.4 25 14 40 300 0.9 0 1.1 0.9 12/14/2005 23:50:00 9.2 1.7 13.7 5.3 8.3 1.7 12.6 3.8 7.1 1.4 11.5 3.8 25 13 36 300 0.8 0 0.9 0.7 12/15/2005 00:00:00 7.2 1.5 11.1 3.4 6.7 1.5 10.7 3.4 5.6 1.5 10.3 1.9 25 17 32 300 0.9 0 0.9 0.9 12/15/2005 00:10:00 6.7 1.7 10.7 3 6.2 1.7 10.3 2.3 5.5 1.5 9.5 2.3 21 17 13 300 0.9 0 1.1 0.9 12/15/2005 00:20:00 6.7 1.8 12.2 0.7 6.2 1.7 11.8 1.1 5.3 1.5 9.9 1.9 25 22 40 300 0.9 0 1.1 0.9 12/15/2005 00:30:00 7.4 1.7 11.8 3 6.8 1.7 11.1 2.6 5.7 1.4 10.3 1.9 25 16 350 300 0.9 0 0.9 0.9 12/15/2005 00:40:00 8.8 1.6 12.6 4.9 8 1.6 11.8 4.2 6.8 1.7 12.2 3 23 13 20 300 1.1 0 1.4 0.9 12/15/2005 00:50:00 8.1 1.5 11.5 4.6 7.3 1.3 10.7 4.2 6.2 1.4 10.3 2.6 30 13 30 300 1.5 0 1.8 1.4 12/15/2005 01:00:00 8 1.8 13.3 4.2 7.3 1.7 12.2 3.4 6.1 1.6 11.5 1.9 28 16 30 300 1.5 0 1.8 1.4 12/15/2005 01:10:00 9 1.7 12.6 3.8 8.2 1.7 12.2 3.4 6.9 1.8 11.1 3 26 15 31 300 1.4 0 1.6 1.4 12/15/2005 01:20:00 10.1 1.8 14.9 6.1 9.2 1.7 14.1 5.3 7.7 1.7 12.6 3 24 12 34 300 1.5 0 1.6 1.4 12/15/2005 01:30:00 9.7 1.7 14.5 5.7 8.7 1.6 13 4.9 7.4 1.6 11.8 3.8 28 12 19 300 1.5 0 1.6 1.4 12/15/2005 01:40:00 8.4 2 12.6 2.3 7.6 2 13 2.3 6.3 1.7 12.2 1.9 25 15 16 300 1.5 0 1.6 1.4 12/15/2005 01:50:00 7.6 1.7 12.6 2.3 7 1.7 11.8 2.3 6.1 1.5 10.3 1.9 25 17 32 300 1.5 0 1.6 1.4 12/15/2005 02:00:00 9.1 1.5 13.3 4.6 8.1 1.6 12.6 4.2 7 1.4 11.5 3.4 26 12 34 300 1.6 0 1.8 1.4 12/15/2005 02:10:00 8.9 1.6 13.3 4.2 8 1.6 12.2 3.4 6.9 1.4 10.7 3 26 13 16 300 1.7 0 1.8 1.6 12/15/2005 02:20:00 8 1.9 13.7 3.4 7.3 1.9 13 3.4 6.2 1.5 11.8 2.3 26 17 42 300 1.5 0 1.6 1.4 12/15/2005 02:30:00 8.1 1.7 13 3.4 7.4 1.6 12.6 2.6 6.5 1.5 11.5 3.4 28 15 17 300 1.4 0 1.6 1.4 12/15/2005 02:40:00 9.1 1.7 13.3 4.2 8.2 1.7 12.6 4.2 6.9 1.5 10.7 3.4 28 13 41 300 1.3 0 1.6 1.4 12/15/2005 02:50:00 9.2 1.5 13.7 5.7 8.3 1.5 13.3 4.9 7 1.7 11.8 2.6 26 13 16 300 1.5 0 1.8 1.4 12/15/2005 03:00:00 7 2 12.6 3 6.5 1.7 11.5 2.6 5.8 1.5 9.9 2.3 37 17 26 300 1.8 0 1.8 1.6 12/15/2005 03:10:00 8 1.5 11.1 4.2 7.4 1.5 11.5 3.4 6.5 1.5 11.5 2.6 35 13 24 300 2 0 2.3 1.8 12/15/2005 03:20:00 6.3 1.5 9.9 2.3 5.9 1.4 10.3 2.3 4.8 1.5 9.1 1.1 40 19 30 300 2.1 0 2.3 2.1 12/15/2005 03:30:00 5.1 1.3 8.8 1.1 5 1.3 8.8 1.1 4.2 1.2 7.6 1.9 56 19 59 300 1.9 0 2.1 1.8 12/15/2005 03:40:00 5.9 1.2 9.1 3 5.7 1.3 9.5 3 4.8 1.3 8 1.5 46 15 53 300 1.8 0 1.8 1.8 12/15/2005 03:50:00 6.3 1.4 9.9 2.3 6.1 1.3 9.1 1.9 4.9 1.3 8.8 1.5 44 15 37 300 1.8 0 1.8 1.6 12/15/2005 04:00:00 6.3 1.5 10.7 1.9 6 1.5 9.9 1.9 5.2 1.3 9.5 1.5 39 17 52 300 1.7 0 1.8 1.6 12/15/2005 04:10:00 7.5 2.2 12.6 2.6 7 2.2 12.6 1.9 5.8 2.1 11.5 1.9 39 16 57 300 1.7 0 1.8 1.6 12/15/2005 04:20:00 8.8 2.1 14.5 3 8 2 13.3 2.3 6.7 1.9 11.5 1.5 30 15 22 300 1.8 0 1.8 1.8 12/15/2005 04:30:00 10.8 1.8 15.3 6.1 9.8 1.7 14.9 5.3 8.3 1.7 13.7 4.2 26 13 31 300 1.8 0 1.8 1.8 12/15/2005 04:40:00 9.6 1.8 14.1 4.2 8.7 1.8 13.7 3.4 7.5 1.7 12.2 3.4 29 12 19 300 1.8 0 1.8 1.8 12/15/2005 04:50:00 10.4 1.7 15.3 5.7 9.4 1.7 15.3 4.2 7.8 1.8 12.6 3.4 26 12 24 300 1.8 0 2.1 1.8 12/15/2005 05:00:00 10.8 2.1 15.3 4.9 9.8 2 14.1 4.6 8.4 1.7 14.1 3.8 27 15 16 300 1.8 0 2.1 1.8 12/15/2005 05:10:00 11.3 2.1 17.6 6.8 10.4 1.9 15.3 5.7 8.9 1.8 14.5 3.8 28 13 18 300 2.1 0 2.3 1.8 12/15/2005 05:20:00 11.6 2.2 16.8 4.9 10.5 2.1 15.3 3.8 9 2 14.9 3.8 24 12 4 300 2.1 0 2.3 2.1 12/15/2005 05:30:00 11.1 1.9 15.3 6.1 10 1.7 14.5 5.3 8.5 1.8 13.7 3.8 24 12 4 300 2.3 0 2.3 2.3 12/15/2005 05:40:00 11.1 2.2 16.4 6.1 10 2 15.6 5.7 8.7 2 14.1 3.8 25 13 13 300 2.3 0 2.3 2.1 12/15/2005 05:50:00 11.2 1.8 16.1 6.8 10 1.6 15.6 6.8 8.7 1.8 13.7 4.2 25 12 31 300 2.5 0 2.8 2.3 12/15/2005 06:00:00 10.7 1.9 15.6 5.7 9.7 1.7 16.1 4.9 8.4 1.9 13.7 3.8 25 12 11 300 2.7 0 2.8 2.6 12/15/2005 06:10:00 9.8 2.2 14.5 4.6 8.9 2 13.7 4.6 7.6 2 12.6 2.3 26 15 41 300 2.7 0 2.8 2.6 12/15/2005 06:20:00 9.7 1.7 14.5 5.7 8.7 1.6 13.3 4.9 7.3 1.5 11.1 3 27 12 27 300 2.9 0 2.8 2.8 12/15/2005 06:30:00 10.3 1.5 14.5 6.1 9.4 1.5 14.5 5.7 7.9 1.7 13.7 3.8 23 13 14 300 2.9 0 3 2.8 12/15/2005 06:40:00 10.7 1.8 14.5 5.7 9.7 1.7 13.7 5.3 8.1 1.7 12.6 3.4 23 12 17 300 2.9 0 3 2.8 12/15/2005 06:50:00 10.2 1.5 14.5 5.3 9.3 1.5 14.5 4.9 8 1.4 13 4.9 23 12 30 300 2.9 0 3.3 2.8 12/15/2005 07:00:00 10.3 1.5 14.1 6.1 9.3 1.5 13 4.9 7.9 1.5 12.2 4.2 23 12 28 300 3.1 0 3.3 3 12/15/2005 07:10:00 10 1.6 13.7 4.6 9.1 1.7 13.3 4.6 7.7 1.5 12.6 3.8 23 12 29 300 3.2 0 3.3 3.3 12/15/2005 07:20:00 9.4 1.7 14.1 4.9 8.5 1.7 13.7 4.6 6.9 1.6 12.2 2.3 23 13 20 300 3.2 0 3.3 3 12/15/2005 07:30:00 9.9 1.5 13.3 4.9 8.9 1.5 13.7 4.2 7.4 1.7 13 3.8 25 13 30 300 3.1 0 3.3 2.8 12/15/2005 07:40:00 10 1.6 14.1 6.1 9.1 1.5 14.5 4.9 7.7 1.7 12.6 2.6 21 12 18 300 3 0 3.3 2.8 12/15/2005 07:50:00 9.6 2.1 14.5 4.2 8.6 1.9 13.7 3 7.5 1.8 12.2 3.4 26 13 27 300 3.2 0 3.3 3 12/15/2005 08:00:00 10 1.5 14.1 6.5 9.2 1.5 13.7 5.3 7.8 1.5 11.8 4.2 20 12 32 300 3.3 0 3.5 3.3 12/15/2005 08:10:00 8.6 1.6 12.2 4.6 8 1.7 12.6 4.2 6.7 1.5 11.1 3.4 20 15 22 300 3.5 0 3.5 3.5 12/15/2005 08:20:00 8.7 1.8 14.9 4.9 8.3 1.9 13.7 4.2 6.6 1.7 12.2 3 14 20 24 300 3.6 0 3.5 3.5 12/15/2005 08:30:00 9.5 2.1 14.5 4.2 9.1 2.3 14.1 3.8 7.1 2.1 13 2.6 14 16 8 300 3.6 0 3.8 3.5 12/15/2005 08:40:00 9.7 2.2 15.3 3.8 8.9 2.1 14.1 3 7.6 1.9 13 3.8 21 14 23 300 3.9 0.1 4.3 3.8 12/15/2005 08:50:00 8.3 1.8 12.6 3.4 7.7 1.8 12.2 3.4 6.4 1.6 10.7 2.6 21 17 5 300 4.3 0 4.5 4.3 12/15/2005 09:00:00 7.2 1.3 11.5 4.2 6.5 1.3 11.5 3.8 5.6 1.3 9.9 2.6 29 16 14 300 4.3 0 4.5 4.3 12/15/2005 09:10:00 6.3 1.7 11.8 2.3 5.8 1.7 11.5 2.3 5 1.5 11.1 1.5 33 18 34 300 4.1 0 4.3 4 12/15/2005 09:20:00 8.6 1.9 13.3 3.8 7.7 1.8 12.6 3.4 6.6 1.7 11.1 2.6 30 14 27 300 4 0 4.3 3.8 12/15/2005 09:30:00 9.6 1.7 14.5 5.7 8.8 1.6 13.3 4.9 7.4 1.5 11.5 3.8 33 13 37 300 3.8 0 4 3.8 12/15/2005 09:40:00 10.4 1.7 14.1 6.1 9.4 1.6 12.6 4.9 7.8 1.6 12.2 3.4 29 13 23 300 3.8 0 3.8 3.5 12/15/2005 09:50:00 10.4 1.5 14.1 6.5 9.3 1.4 13.3 5.7 8 1.5 12.2 3.4 29 12 22 300 3.9 0 4 3.8 12/15/2005 10:00:00 10.3 1.9 14.9 4.9 9.3 1.7 13.3 3.8 8 1.7 13.7 2.6 26 13 25 300 4 0 4 3.8 12/15/2005 10:10:00 10 1.9 14.1 4.9 9.2 1.8 13.3 4.6 7.9 1.8 12.6 2.6 26 15 17 300 4.1 0 4.3 4 12/15/2005 10:20:00 9 2 14.9 4.2 8.3 1.9 15.3 3.8 6.7 2 12.2 2.3 33 17 21 300 4.1 0 4.3 4 12/15/2005 10:30:00 9.3 1.8 13.7 3.8 8.6 1.7 13 3.8 7 1.7 12.2 2.6 33 16 34 300 4.3 0 4.5 4.3 12/15/2005 10:40:00 10.2 1.9 14.9 4.6 9.1 1.7 14.1 4.6 7.7 1.6 12.2 3.4 31 12 26 300 4.3 0 4.5 4.3 12/15/2005 10:50:00 10 1.7 14.5 5.3 9.1 1.5 13.3 4.6 7.7 1.7 12.6 3 30 13 16 300 4.4 0 4.8 4.3 12/15/2005 11:00:00 9.9 1.5 14.1 5.3 9.2 1.5 13.3 4.9 7.6 1.5 11.5 3.8 35 12 7 300 4.8 0 5 4.5 12/15/2005 11:10:00 10.7 1.9 15.3 5.3 9.6 1.8 14.5 5.3 8.3 1.7 13.3 3.8 30 12 39 300 4.9 0 5 5 12/15/2005 11:20:00 9.5 1.9 14.1 4.2 8.6 1.9 13.3 3.4 7.2 1.7 11.5 3 31 13 29 300 5.1 0.1 5.5 4.8 12/15/2005 11:30:00 9.8 1.8 14.1 4.6 8.7 1.7 13.7 3.8 7.3 1.6 11.8 3 26 12 32 300 5.1 0 5.5 5 12/15/2005 11:40:00 9.9 2.2 14.9 4.9 8.9 2 13.3 4.6 7.5 2.2 13.3 1.9 26 15 27 300 5.1 0 5.2 5 12/15/2005 11:50:00 11 2.2 15.3 4.6 9.8 1.9 14.5 4.6 8.1 1.9 13 3.4 26 10 25 300 4.9 0 5 4.8 12/15/2005 12:00:00 11 1.8 15.3 6.1 10 1.8 15.6 5.3 8.8 1.8 14.5 3.4 23 12 29 300 5 0 5 4.8 12/15/2005 12:10:00 10.6 1.7 14.5 6.1 9.7 1.7 15.3 4.9 8 1.7 13 4.2 22 12 13 300 5.1 0 5 5 12/15/2005 12:20:00 9.6 1.8 14.5 4.6 8.8 1.7 14.1 3.8 7.2 1.7 11.8 3 24 15 21 300 5.1 0 5.2 4.8 12/15/2005 12:30:00 8.2 1.6 12.6 3.8 7.5 1.5 13 3.4 6.2 1.6 10.7 1.9 32 15 43 300 5.4 0 5.5 5.2 12/15/2005 12:40:00 7.3 1.7 11.1 3.8 6.7 1.6 10.7 3.4 5.2 1.5 8.8 1.5 32 16 39 300 5.4 0.1 5.7 5.2 12/15/2005 12:50:00 6.4 1.8 11.8 3 6.3 1.9 11.5 2.6 4.9 1.8 10.3 1.5 59 20 70 300 6.6 0.8 8.5 5.7 12/15/2005 13:00:00 7.6 1.8 13.3 4.2 7.5 1.9 13.3 3.4 6.4 1.9 11.8 2.6 63 20 47 300 8.7 0.1 9 8.3 12/15/2005 13:10:00 8.4 1.6 11.8 3.4 8.2 1.7 11.8 3.4 6.4 1.7 11.5 2.3 46 17 45 300 7.6 0.9 9 6.5 12/15/2005 13:20:00 8 1.7 11.5 3.8 7.5 1.7 11.8 3.4 5.8 1.9 11.1 1.9 39 15 36 300 6.3 0.4 6.7 5.7 12/15/2005 13:30:00 7.2 1.7 11.5 3.4 6.7 1.8 11.1 2.6 5.6 1.8 10.7 1.5 42 14 39 300 5.9 0 6 5.7 12/15/2005 13:40:00 5.1 1.6 8.8 0.7 4.7 1.5 8.8 0.7 3.9 1.3 7.6 1.1 31 26 12 300 5.3 0.2 5.7 5 12/15/2005 13:50:00 2.1 1.3 6.1 0.4 1.9 1.3 6.1 0.4 1.5 0.9 4.2 0.4 1 66 7 300 5.1 0 5.2 5 12/15/2005 14:00:00 1.9 1.3 6.8 0.4 1.8 1.2 6.1 0.4 1.6 1 4.6 0.4 348 86 16 300 5.8 0.2 6.2 5.2 12/15/2005 14:10:00 3.1 1.4 7.6 0.7 2.9 1.3 6.8 0.4 2.4 1.1 6.1 0.4 20 29 36 300 6.2 0.1 6.7 6 12/15/2005 14:20:00 6.2 1.5 11.1 2.3 5.7 1.5 10.7 1.5 4.7 1.4 9.5 1.5 30 14 40 300 6.5 0 6.7 6.5 12/15/2005 14:30:00 6.4 1.6 10.7 3 5.7 1.4 9.5 2.3 4.7 1.2 8.4 2.3 27 15 28 300 6.1 0.3 6.7 5.7 12/15/2005 14:40:00 8.3 1.9 13 3 7.8 1.9 12.6 3 6.2 1.8 12.2 1.5 34 15 27 300 5.4 0 5.7 5.2 12/15/2005 14:50:00 7.9 1.8 12.6 3 7.4 2 12.6 2.6 5.8 1.7 10.7 1.5 43 18 51 300 5.2 0.1 5.5 5 12/15/2005 15:00:00 8.7 1.7 12.6 4.6 8.3 1.7 12.6 3.8 6.3 1.6 10.7 2.6 40 14 33 300 5.2 0.1 5.7 5 12/15/2005 15:10:00 9.3 1.6 14.5 4.6 9 1.7 14.1 4.6 6.8 1.6 11.1 3.4 42 15 37 300 5.1 0.4 6 4.5 12/15/2005 15:20:00 8.9 1.9 14.5 3.8 8.8 2 14.9 2.6 6.2 1.7 11.1 3 47 15 44 300 5.7 0.2 6.2 5.5 12/15/2005 15:30:00 8.8 2.3 14.9 3.8 8.8 2.4 14.9 3.8 6.8 2.2 13.7 1.5 59 17 70 300 7.1 0.5 7.5 6.2 12/15/2005 15:40:00 8.7 1.8 13.3 4.6 8.6 1.9 13.7 3.4 6.5 1.7 11.8 2.6 55 15 56 300 6.9 0.2 7.5 6.7 12/15/2005 15:50:00 10 2.2 15.3 4.6 10 2.2 15.6 4.6 7.8 2.3 13.7 3 59 16 64 300 6.7 0 7.3 6.5 12/15/2005 16:00:00 11.8 2.7 19.9 4.9 11.9 2.8 20.2 4.2 9.8 2.7 18.3 4.2 64 15 81 300 7.5 0.2 8 7 12/15/2005 16:10:00 13 2.7 20.2 6.8 13.2 2.8 20.6 6.1 11.6 2.8 20.6 5.7 70 12 95 300 8.3 0.2 8.8 7.8 12/15/2005 16:20:00 13.1 2.5 19.1 5.7 13.3 2.5 18.7 5.7 11.3 2.6 18.3 4.9 73 13 73 300 8.7 0 9 8.5 12/15/2005 16:30:00 13.5 2.6 19.5 6.8 13.7 2.6 19.9 6.8 11.9 2.7 18.7 4.9 73 13 70 300 9 0 9.3 8.8 12/15/2005 16:40:00 13.3 2.9 20.2 6.8 13.4 2.9 21 7.2 11.6 2.7 18.3 5.3 73 13 82 300 9.2 0 9.3 9 12/15/2005 16:50:00 14.3 2.9 21.8 7.6 14.4 3.1 22.1 8 12.5 3.1 20.6 6.1 74 13 79 300 9.2 0 9.3 9 12/15/2005 17:00:00 13.9 2.8 21 5.7 14 2.9 20.2 5.3 12.4 2.9 20.6 4.9 75 13 77 300 9.1 0 9.3 9 12/15/2005 17:10:00 12.7 2.9 21 6.1 12.7 2.9 20.6 5.7 11 2.8 19.9 4.2 72 13 79 300 9 0 9.3 9 12/15/2005 17:20:00 13 2.8 20.6 7.2 13.1 2.8 20.6 6.8 11.7 2.6 19.9 5.3 74 14 65 300 9.2 0 9.3 9 12/15/2005 17:30:00 12 2.5 20.2 4.9 12.1 2.6 20.6 6.1 10.1 2.5 17.6 4.6 72 15 67 300 9 0 9.3 9 12/15/2005 17:40:00 13.1 2.9 20.2 5.3 13.3 2.9 21 4.9 11.5 2.9 17.9 4.2 73 15 75 300 9.2 0 9.3 9 12/15/2005 17:50:00 12 2.7 18.7 6.1 12.2 2.7 18.7 6.5 10.5 2.6 17.9 5.3 71 13 77 300 9.1 0 9.3 9 12/15/2005 18:00:00 12.1 2.6 18.7 5.3 12.3 2.6 18.7 4.9 10.3 2.6 17.6 4.2 69 15 80 300 9 0 9.3 9 12/15/2005 18:10:00 10.2 2.6 17.2 4.2 10.3 2.6 16.8 3.4 8.5 2.7 16.1 3 67 17 71 300 8.9 0 9.3 8.8 12/15/2005 18:20:00 10.1 2.5 16.8 3.8 10.1 2.6 16.4 4.2 8.3 2.4 14.9 3 65 15 73 300 9 0 9 8.8 12/15/2005 18:30:00 9.9 2.3 15.6 4.9 9.8 2.4 16.1 4.6 7.7 2.4 14.1 2.6 60 15 71 300 8.9 0 9 8.8 12/15/2005 18:40:00 11 2.4 17.6 3.8 11 2.5 17.9 4.6 9.4 2.2 17.2 4.9 66 15 77 300 9.2 0 9.3 8.8 12/15/2005 18:50:00 12 2.8 18.7 5.7 12.1 2.8 18.7 5.7 10.2 2.9 17.6 4.2 67 17 72 300 9.3 0 9.6 9 12/15/2005 19:00:00 12.9 2.9 22.9 5.3 13 3.1 22.9 5.7 10.9 3.2 19.1 3.8 69 14 67 300 9.5 0 9.6 9.3 12/15/2005 19:10:00 12.5 2.7 21 5.3 12.5 2.7 21.8 5.3 10.4 2.8 19.1 4.2 63 16 63 300 9.5 0 9.6 9.6 12/15/2005 19:20:00 10.4 2.7 17.6 4.2 10.5 2.8 17.6 4.6 9.1 2.5 16.8 3.8 66 17 57 300 9.5 0 9.6 9.3 12/15/2005 19:30:00 10.2 2.6 17.6 4.2 10.1 2.7 17.9 2.6 8.3 2.8 16.1 2.6 60 18 53 300 9.4 0 9.6 9.3 12/15/2005 19:40:00 9.6 2.8 17.2 2.3 9.5 2.9 17.6 1.9 7.7 2.6 15.3 2.3 58 22 49 300 9.2 0.1 9.6 9 12/15/2005 19:50:00 8.9 2.3 14.9 3.8 8.8 2.3 15.3 4.2 6.9 2.1 12.6 2.3 58 19 48 300 8.9 0 9 8.8 12/15/2005 20:00:00 9.7 2 14.9 4.6 9.8 2 14.5 4.6 7.9 2.3 14.5 2.3 58 16 39 300 8.7 0 9 8.5 12/15/2005 20:10:00 9.5 2.1 14.9 4.6 9.6 2.2 14.9 3.8 7.3 2 13.7 3.4 56 16 63 300 8.4 0 8.8 8.3 12/15/2005 20:20:00 9.4 1.9 14.5 4.6 9 1.9 13.7 3.8 6.9 2.1 12.2 1.9 39 14 40 300 8.1 0.1 8.5 8 12/15/2005 20:30:00 8.5 2 14.9 4.2 8.2 2 14.9 3.8 6.6 1.9 13.3 2.6 44 13 38 300 7.9 0.1 8.3 7.5 12/15/2005 20:40:00 7.9 1.7 12.2 3.8 7.4 1.6 11.8 3.8 6 1.5 11.5 2.6 37 14 40 300 7.6 0.1 7.8 7.3 12/15/2005 20:50:00 7.8 1.7 12.2 3.4 7.6 1.7 11.8 2.6 5.8 1.7 11.1 1.5 45 15 47 300 7.3 0 7.5 7.3 12/15/2005 21:00:00 8.3 1.7 12.6 4.2 8.1 1.9 12.6 3.4 6.4 1.9 11.1 2.6 50 17 55 300 7.1 0 7.3 7 12/15/2005 21:10:00 8.6 1.7 13.7 3.4 8.5 1.7 13.7 3.8 6.7 2.1 12.2 1.1 55 14 57 300 7.1 0 7.3 7 12/15/2005 21:20:00 8.2 1.9 11.8 2.3 8.2 2 12.2 1.9 6.5 2 12.2 0.7 57 15 75 300 7 0 7.3 7 12/15/2005 21:30:00 8.4 2 12.6 2.6 8.2 2 12.6 3.4 6.3 2 11.8 2.3 50 18 41 300 6.7 0 7 6.7 12/15/2005 21:40:00 9 1.7 14.1 3.8 9 1.8 14.1 3.8 7 2 12.6 2.6 53 14 46 300 6.6 0 6.7 6.5 12/15/2005 21:50:00 7.9 1.8 13.3 3.8 7.6 2 12.6 3 5.6 1.8 11.5 2.3 45 17 43 300 6.5 0 6.7 6.5 12/15/2005 22:00:00 9.2 1.5 13.3 4.9 8.9 1.6 13.7 4.2 6.8 1.6 11.8 3 40 13 48 300 6.6 0 6.7 6.5 12/15/2005 22:10:00 10.7 2.1 16.8 5.7 10.3 2.2 16.4 4.9 8.3 2 14.5 3.8 39 10 49 300 6.7 0.1 7 6.5 12/15/2005 22:20:00 12.2 2.2 17.6 6.8 11.8 2.4 17.6 5.7 9.6 2.5 17.9 3.4 38 12 46 300 7 0 7.3 7 12/15/2005 22:30:00 13.3 2.3 19.1 7.2 12.8 2.4 18.3 6.5 10.3 2.5 16.4 5.3 38 12 44 300 7.7 0.2 7.8 7.3 12/15/2005 22:40:00 12.6 2.5 18.3 7.2 11.7 2.5 17.6 6.1 9.5 2.5 15.3 2.6 31 13 25 300 8.1 0.2 8.5 7.8 12/15/2005 22:50:00 10.3 2.5 16.1 4.9 9.8 2.4 15.3 4.2 8 2.4 14.5 3.4 41 17 33 300 8.3 0 8.5 8.3 12/15/2005 23:00:00 12.6 2.5 19.5 3.8 11.4 2.3 17.2 4.2 9.2 2 15.3 4.2 31 13 31 300 8.1 0.2 8.5 7.8 12/15/2005 23:10:00 11.5 2 16.1 4.9 10.4 1.9 16.1 4.9 8.7 2 14.5 4.2 25 12 31 300 7.6 0.1 8 7.5 12/15/2005 23:20:00 9.3 1.5 14.1 5.7 8.6 1.7 13.7 4.6 7.3 1.6 11.8 3.4 27 13 53 300 7.4 0 7.5 7.3 12/15/2005 23:30:00 7.6 1.4 11.5 3.8 7 1.3 11.8 3.8 6 1.3 9.9 3 33 15 17 300 7.3 0 7.5 7.3 12/15/2005 23:40:00 6 1.3 11.5 3 5.7 1.5 12.2 2.3 4.7 1.3 9.1 1.9 48 20 69 300 7.3 0 7.8 7.3 12/15/2005 23:50:00 7.6 2.3 15.6 1.9 7.7 2.4 15.6 1.9 6.8 2.1 13.7 1.9 72 17 87 300 8.5 0.2 8.8 7.8 12/16/2005 00:00:00 7 2.2 13.3 1.9 7 2.3 14.1 1.9 5.7 2 12.2 1.1 63 18 66 300 8.5 0.1 9 8.3 12/16/2005 00:10:00 8.4 1.8 13 3.8 8.4 1.9 13 4.6 6.7 1.8 12.2 2.3 54 13 67 300 8.2 0 8.5 8.3 12/16/2005 00:20:00 9 1.7 13.3 4.2 8.7 1.7 13 4.2 7 2 12.2 3 45 15 46 300 8 0 8.3 7.8 12/16/2005 00:30:00 9 1.7 13.7 3.8 8.3 1.9 13.7 3 6.6 1.8 11.8 3 32 14 38 300 7.4 0.1 7.8 7.3 12/16/2005 00:40:00 9 1.5 13.3 4.2 8.3 1.6 12.2 3.4 7.1 1.5 10.7 3.4 21 11 13 300 7.3 0 7.5 7.3 12/16/2005 00:50:00 8.3 1.6 11.8 4.2 7.8 1.7 12.2 3 6.4 1.6 11.1 3 20 16 359 300 7.3 0 7.5 7.3 12/16/2005 01:00:00 7 1.5 10.7 2.6 6.8 1.5 10.7 2.3 5.6 1.5 9.5 2.3 50 19 40 300 7.6 0.2 7.8 7.3 12/16/2005 01:10:00 8.3 1.6 12.6 4.6 7.8 1.5 12.2 3.8 6.7 1.5 11.1 3 36 13 27 300 8 0 8 7.8 12/16/2005 01:20:00 10.9 1.7 14.5 6.5 10 1.7 13.7 6.1 8.3 1.7 13.7 4.2 26 14 32 300 8.1 0 8.3 8 12/16/2005 01:30:00 10.4 1.9 16.1 4.9 9.4 1.8 14.9 5.3 8 2 14.1 3.8 26 13 27 300 8 0 8.3 7.8 12/16/2005 01:40:00 8.3 2.1 13 3.4 7.8 1.9 12.6 3.4 6.3 1.8 12.2 3 38 17 17 300 7.9 0 8.3 7.8 12/16/2005 01:50:00 6.3 1.2 9.9 3 6 1.2 9.1 3 4.9 1.2 7.6 1.9 42 17 24 300 8 0 8.3 7.8 12/16/2005 02:00:00 8.4 1.8 13.3 3.8 8 2 13 3 6.3 2.1 11.8 1.9 42 15 43 300 8.1 0 8.3 8.3 12/16/2005 02:10:00 7.9 1.5 12.6 3.8 7.4 1.4 11.5 4.2 6.2 1.5 11.1 2.3 42 16 13 300 8.2 0 8.5 8 12/16/2005 02:20:00 8.1 1.5 13.7 4.6 7.8 1.6 13.3 4.6 6.4 1.5 10.7 2.6 44 12 48 300 8 0 8.3 7.8 12/16/2005 02:30:00 8 1.7 14.5 4.2 7.7 1.9 14.5 3.8 6.4 1.8 13 2.6 44 14 41 300 8 0 8.3 7.8 12/16/2005 02:40:00 8.4 1.7 14.1 4.2 7.9 1.9 14.5 3.4 6.3 1.7 12.6 2.3 40 15 64 300 8 0 8.3 7.8 12/16/2005 02:50:00 7.5 1.2 11.1 3.8 7.1 1.4 11.5 3 5.9 1.4 9.5 3 38 13 64 300 7.9 0 8 7.8 12/16/2005 03:00:00 8 1.5 11.8 4.2 7.3 1.6 11.8 3.4 6.1 1.5 10.7 2.6 33 14 18 300 7.8 0 8 7.8 12/16/2005 03:10:00 10.4 2.2 17.9 4.9 9.4 2.2 14.9 3.8 7.8 2 15.6 2.3 31 13 21 300 7.9 0 8 7.8 12/16/2005 03:20:00 9.6 2.3 16.4 4.6 9.3 2.4 16.4 4.2 7.6 2.4 15.6 1.9 45 16 51 300 8 0 8.3 7.8 12/16/2005 03:30:00 8.7 2.2 15.3 3.8 8.3 2.2 14.9 3 6.7 2.1 13.3 2.3 45 18 30 300 8 0 8.3 7.8 12/16/2005 03:40:00 9.8 2.1 15.3 4.6 9.2 2.2 14.5 3.4 7.1 2.1 13.7 1.9 37 17 32 300 8.2 0 8.5 8.3 12/16/2005 03:50:00 10 2.4 16.4 2.6 9.5 2.5 16.1 2.3 7.5 2.4 14.5 3 41 15 44 300 8.3 0 8.5 8.3 12/16/2005 04:00:00 8.3 1.7 14.5 3.4 7.9 1.7 13.7 2.6 6.4 1.7 11.5 2.3 42 15 46 300 8.1 0 8.3 8 12/16/2005 04:10:00 8.2 1.7 12.2 3.4 8 1.8 12.6 2.6 6.4 1.8 10.7 1.9 47 14 73 300 8 0 8.3 7.8 12/16/2005 04:20:00 8.2 1.4 11.5 4.6 7.9 1.5 11.5 3.8 6.6 1.5 10.3 2.3 44 14 40 300 8.1 0 8.3 8 12/16/2005 04:30:00 8.5 2.6 14.9 2.6 8.3 2.7 15.3 2.6 6.8 2.8 14.5 1.5 56 21 76 300 8.1 0.2 8.5 7.8 12/16/2005 04:40:00 9 2.3 14.9 2.6 8.7 2.4 16.1 1.5 6.8 1.9 15.3 2.3 48 17 43 300 8.2 0 8.5 8 12/16/2005 04:50:00 7.8 1.9 13.7 4.2 7.6 2.1 13.7 3 5.8 2.2 11.5 1.5 49 21 43 300 8.1 0 8.3 8 12/16/2005 05:00:00 6.3 2 11.5 2.3 5.9 2 11.1 2.3 4.9 1.8 10.7 1.5 43 21 39 300 8 0 8.3 7.8 12/16/2005 05:10:00 7 2 14.1 2.6 6.7 2.1 14.1 2.6 5.4 2 13 1.1 49 20 69 300 7.8 0 7.8 7.8 12/16/2005 05:20:00 7.6 1.4 11.8 4.2 7.1 1.5 11.5 3.4 5.6 1.3 8.8 1.9 38 17 38 300 7.8 0 8 7.8 12/16/2005 05:30:00 7.8 1.7 13 2.3 7.4 1.8 12.6 2.6 6 1.8 11.5 0.7 43 17 35 300 7.9 0 8 7.8 12/16/2005 05:40:00 8.9 1.8 14.5 4.9 8.5 1.9 14.1 3.8 6.8 2.1 12.6 2.6 40 14 39 300 8 0 8 7.8 12/16/2005 05:50:00 8.7 2.1 13 3.8 8.4 2.2 13 3.8 6.4 2.1 13 1.9 44 17 51 300 8 0 8.3 7.8 12/16/2005 06:00:00 12.3 2.2 20.2 6.1 11.8 2.2 19.1 4.9 9.4 2.3 14.5 3.4 37 12 36 300 8.3 0.2 8.8 8 12/16/2005 06:10:00 10.8 1.8 15.3 4.9 10.3 2 15.3 4.6 8.2 2.1 12.6 2.3 40 15 48 300 8.4 0 8.8 8.3 12/16/2005 06:20:00 10.8 2.2 17.2 5.7 10.4 2.3 17.6 4.9 8.5 2.2 16.8 3.4 41 13 64 300 8.3 0 8.5 8.3 12/16/2005 06:30:00 8.1 1.5 12.2 4.2 7.8 1.7 12.2 3.4 6.3 1.7 10.3 1.5 41 13 61 300 8 0.1 8.3 7.8 12/16/2005 06:40:00 9.1 2.2 14.5 2.3 9 2.4 14.5 1.9 7.5 2.5 14.1 1.9 62 20 84 300 7.7 0 7.8 7.5 12/16/2005 06:50:00 8.5 1.9 13.3 3.8 8.4 2.1 13.7 3.8 6.9 1.9 11.8 1.9 59 19 76 300 7.6 0 7.8 7.5 12/16/2005 07:00:00 9.1 1.9 13.3 4.6 9.1 2 14.9 4.6 7.7 1.8 12.6 3.8 68 18 77 300 7.6 0 7.8 7.5 12/16/2005 07:10:00 9.2 2.5 14.5 3.8 9.2 2.6 15.3 3.4 7.5 2.4 13.3 2.6 66 17 66 300 7.6 0 7.8 7.5 12/16/2005 07:20:00 9.2 2.2 14.1 3.4 9.2 2.3 13.7 2.6 7.6 2.2 13 3 63 16 70 300 7.5 0.2 7.8 7.3 12/16/2005 07:30:00 9.9 2.4 16.8 3.8 9.8 2.5 16.4 3.4 8.1 2.4 16.4 3 63 17 72 300 7.3 0 7.3 7.3 12/16/2005 07:40:00 10.1 2.6 17.9 3.8 10.1 2.7 17.9 3.4 8.5 2.7 17.2 2.3 65 17 67 300 7.3 0 7.3 7 12/16/2005 07:50:00 10 2.4 16.4 3.8 10.2 2.5 16.8 3.8 8.5 2.5 14.9 1.9 70 15 75 300 7 0 7.3 7 12/16/2005 08:00:00 8.9 2.1 14.9 2.6 8.9 2.3 14.9 1.5 7.5 2.3 15.6 3 66 16 75 300 7 0 7.3 7 12/16/2005 08:10:00 8.7 1.9 13.7 3.8 8.7 1.9 13.7 3.4 7.2 1.7 13.3 3.4 65 15 76 300 6.8 0 7 6.7 12/16/2005 08:20:00 9.8 2 15.6 4.6 9.8 2.1 15.6 3.8 7.8 2.1 13.7 3.8 67 17 72 300 7 0 7.3 6.7 12/16/2005 08:30:00 9 2.2 15.6 4.2 9 2.3 15.6 3.4 7.5 2.1 14.9 3 63 18 61 300 6.7 0 7 6.7 12/16/2005 08:40:00 7.7 1.8 15.3 3.8 7.7 1.9 14.9 3.4 6.3 1.8 12.6 2.6 61 17 80 300 6.5 0 6.7 6.5 12/16/2005 08:50:00 8.6 2.1 16.4 3.8 8.7 2.2 16.4 3.4 7.6 2 15.3 3.8 64 17 79 300 6.7 0 6.7 6.5 12/16/2005 09:00:00 9.6 2.4 16.4 2.6 9.6 2.5 16.1 4.2 8 2.6 15.6 1.9 66 17 80 300 6.7 0 7 6.7 12/16/2005 09:10:00 11.1 2.4 16.4 4.9 11.2 2.5 17.2 4.6 9.6 2.3 16.1 4.6 74 13 62 300 6.7 0 7 6.7 12/16/2005 09:20:00 10.9 2.3 16.4 5.3 11 2.3 17.2 5.3 9.4 2.2 16.1 3.8 73 15 74 300 6.7 0 6.7 6.5 12/16/2005 09:30:00 11.3 2.2 16.8 5.3 11.4 2.2 16.4 5.7 9.6 2.3 16.4 4.9 74 13 77 300 6.5 0 6.7 6.5 12/16/2005 09:40:00 11.5 2 16.1 6.1 11.7 2 16.1 6.5 10.1 2.1 15.6 4.9 73 12 82 300 6.4 0 6.7 6.2 12/16/2005 09:50:00 10.7 2.4 16.1 4.2 10.7 2.4 15.6 4.6 9.2 2.3 14.9 3 72 13 61 300 6.4 0 6.5 6.2 12/16/2005 10:00:00 10.8 1.8 15.6 5.7 10.9 1.8 15.6 5.7 9.4 2.1 14.5 4.2 74 13 70 300 6.4 0 6.7 6.2 12/16/2005 10:10:00 11 2.1 16.4 5.7 11.2 2.1 16.8 6.1 9.3 2.2 14.9 3.8 72 12 76 300 6.5 0 6.7 6.2 12/16/2005 10:20:00 11.3 2 15.6 6.5 11.4 2 15.6 6.5 9.9 2.1 14.5 5.7 75 13 84 300 6.4 0 6.7 6.2 12/16/2005 10:30:00 11.6 2.1 16.4 6.8 11.7 2.1 16.4 6.5 9.8 2.1 15.3 4.9 74 13 68 300 6.4 0 6.5 6.2 12/16/2005 10:40:00 11.5 1.8 16.1 6.8 11.6 1.9 16.1 6.5 9.9 2.2 15.3 4.9 74 12 77 300 6.4 0 6.7 6.2 12/16/2005 10:50:00 11.5 2.1 17.2 5.3 11.6 2.2 16.8 6.1 9.8 2.1 14.1 4.9 70 12 72 300 6.4 0 6.7 6.2 12/16/2005 11:00:00 11.4 2.3 17.6 6.1 11.4 2.3 17.6 5.3 9.7 2.2 14.9 4.6 73 13 65 300 6.3 0.1 6.5 6.2 12/16/2005 11:10:00 10.8 2.1 16.4 5.3 10.9 2.1 16.1 5.7 9.3 2.1 15.3 4.9 72 13 66 300 6.4 0 6.7 6.2 12/16/2005 11:20:00 9.6 2.1 14.5 3.8 9.7 2.2 14.9 3.4 8.4 2 13 3 67 15 77 300 6.4 0 6.7 6.2 12/16/2005 11:30:00 8.8 1.9 14.5 4.9 8.9 2 14.9 4.6 7.4 1.8 13 3.8 63 15 77 300 6.3 0 6.5 6.2 12/16/2005 11:40:00 9.8 1.9 14.9 4.2 9.9 2 14.9 3.4 8.3 1.8 13.7 4.2 69 15 82 300 6.3 0 6.5 6.2 12/16/2005 11:50:00 10.1 2.2 14.9 4.6 10.3 2.2 14.9 4.2 8.8 2.2 14.1 3.4 68 14 77 300 6.4 0 6.7 6.2 12/16/2005 12:00:00 10.7 2.2 15.6 4.9 10.8 2.3 15.6 4.9 9.2 2.3 14.5 3.8 69 12 63 300 6.2 0 6.5 6.2 12/16/2005 12:10:00 10.1 2.2 16.1 4.9 10.2 2.3 15.6 4.2 8.7 2.5 14.9 3 68 16 62 300 6.4 0 6.5 6.2 12/16/2005 12:20:00 11 1.8 14.9 6.5 11.1 1.8 14.9 6.5 9 1.9 14.5 4.2 71 13 67 300 6.2 0 6.5 6.2 12/16/2005 12:30:00 10 1.8 14.5 4.6 10.1 1.8 14.9 4.9 8.3 1.7 12.6 4.6 72 14 63 300 6.2 0 6.2 6.2 12/16/2005 12:40:00 10 1.8 14.5 5.3 10.1 1.8 14.9 5.3 8.7 1.9 14.5 4.6 71 14 73 300 6.2 0 6.5 6.2 12/16/2005 12:50:00 9.7 1.8 14.5 5.3 9.7 1.8 14.1 4.6 8.2 1.8 13.3 3 70 15 64 300 6.4 0 6.5 6.2 12/16/2005 13:00:00 9.5 1.8 13.7 5.3 9.6 1.8 13.7 5.3 8 1.8 13 3.8 68 14 67 300 6.2 0 6.5 6.2 12/16/2005 13:10:00 10.8 1.7 15.3 5.7 10.9 1.8 15.3 6.1 9.4 2 14.5 3.8 70 11 73 300 6.2 0 6.2 6.2 12/16/2005 13:20:00 10.3 1.9 15.3 4.6 10.4 1.9 14.9 3.4 8.9 1.8 13.3 4.2 71 12 66 300 6.2 0 6.5 6.2 12/16/2005 13:30:00 9.2 2 14.1 3.8 9.2 2.1 13.7 3.4 7.7 1.9 13.3 3.8 67 15 75 300 6.2 0 6.2 6.2 12/16/2005 13:40:00 8.7 1.7 13.3 3.8 8.7 1.7 13.3 3.4 7.2 1.9 11.8 3.4 66 16 85 300 6.2 0 6.2 6 12/16/2005 13:50:00 8.8 2.1 13.7 3.4 8.8 2.3 13.7 3 7.7 2.1 12.6 1.9 67 17 70 300 6.1 0 6.2 6 12/16/2005 14:00:00 9.2 2.2 14.1 4.6 9.3 2.3 14.1 4.2 7.9 2.3 13.3 3.4 64 15 68 300 6 0 6 6 12/16/2005 14:10:00 9.1 2.1 13.7 3.8 9.1 2.2 13.7 2.6 7.7 2.1 13 3.4 68 16 84 300 5.9 0 6 5.7 12/16/2005 14:20:00 10.1 2.2 15.6 4.9 10.2 2.3 15.6 4.2 8.8 2.3 14.1 3.8 70 15 71 300 5.9 0 6 6 12/16/2005 14:30:00 11.2 1.8 15.3 5.7 11.3 1.9 15.6 6.1 9.8 2.1 15.3 4.9 72 12 72 300 6.1 0 6.2 6 12/16/2005 14:40:00 11.2 1.7 16.8 6.5 11.3 1.8 17.2 6.5 9.5 1.7 13.7 5.3 73 14 68 300 5.9 0 6 5.7 12/16/2005 14:50:00 10.8 2 15.3 5.3 10.9 2 15.6 5.3 9.4 2 15.3 5.3 73 13 70 300 5.9 0 6 5.7 12/16/2005 15:00:00 10.1 1.8 14.5 5.3 10.2 1.9 15.3 4.2 8.7 1.9 14.5 3.8 74 15 59 300 5.8 0 6 5.7 12/16/2005 15:10:00 10.4 1.7 14.9 4.9 10.4 1.7 14.1 5.7 8.9 1.7 13.7 4.6 74 13 103 300 5.8 0 6 5.7 12/16/2005 15:20:00 9.6 1.6 14.1 6.1 9.7 1.6 14.9 5.7 8.2 1.8 12.6 3.8 73 14 54 300 5.8 0 6 5.7 12/16/2005 15:30:00 10 2 14.5 4.2 10.1 2 14.5 3.8 8.5 2 13.7 4.6 71 13 67 300 5.6 0 5.7 5.7 12/16/2005 15:40:00 10.3 1.7 14.1 4.9 10.3 1.7 13.7 4.9 8.7 1.9 13.7 4.2 73 12 96 300 5.7 0 5.7 5.7 12/16/2005 15:50:00 8.9 1.8 13 3.4 9 1.9 13.3 4.2 7.6 1.9 12.2 3.4 70 15 55 300 5.7 0 6 5.5 12/16/2005 16:00:00 9.9 2.3 15.3 4.6 9.9 2.4 15.6 4.6 8.5 2.2 14.1 4.2 72 15 58 300 5.7 0 6 5.7 12/16/2005 16:10:00 10 2 14.9 5.7 10.1 2.1 14.5 4.9 8.7 2.3 13.7 4.2 68 12 60 300 5.7 0 5.7 5.7 12/16/2005 16:20:00 9.5 2.4 15.3 3.8 9.6 2.5 15.3 4.2 8 2.4 14.1 2.6 68 16 79 300 5.7 0 6 5.5 12/16/2005 16:30:00 8.3 1.8 13.7 4.2 8.3 1.8 14.1 3.8 6.9 1.8 13.3 3 63 16 63 300 5.6 0 5.7 5.5 12/16/2005 16:40:00 8.8 2 14.1 3 8.9 2 14.1 4.2 7.2 2.1 12.6 2.3 61 15 58 300 5.6 0 5.7 5.5 12/16/2005 16:50:00 8 1.7 12.2 4.2 8 1.7 13 4.2 6.3 1.7 10.3 2.6 64 16 79 300 5.5 0 5.7 5.5 12/16/2005 17:00:00 8 1.7 13 3.4 8 1.6 13.3 3.8 6.6 2 12.2 2.3 65 16 76 300 5.7 0 6 5.7 12/16/2005 17:10:00 9.3 2 13.7 4.6 9.4 2 14.5 4.6 8.1 2.1 14.9 3.8 67 15 63 300 6.1 0 6.2 6 12/16/2005 17:20:00 8.8 1.8 13.7 4.6 8.9 1.9 13.7 4.6 7.7 1.8 12.6 3 68 16 74 300 6.1 0 6.2 6 12/16/2005 17:30:00 9 2.2 14.5 3.4 9 2.3 14.5 3.8 7.8 2.1 13.3 3.4 65 15 73 300 5.9 0.1 6.2 5.7 12/16/2005 17:40:00 9.9 1.9 14.1 5.3 10 2 14.1 4.6 8.3 1.9 13.3 3.4 70 13 68 300 5.9 0 6 5.7 12/16/2005 17:50:00 9 2.4 14.5 3.8 9 2.4 14.1 3 7.8 2.3 13.3 2.6 66 15 78 300 5.9 0 6 5.7 12/16/2005 18:00:00 8.8 1.7 15.3 3.4 8.9 1.7 15.6 3.4 7.5 1.7 11.8 3.4 71 14 57 300 5.7 0 5.7 5.7 12/16/2005 18:10:00 9 2 13.3 3.4 9 2.1 13.3 3.8 7.9 2 12.6 3 69 15 77 300 5.7 0 6 5.7 12/16/2005 18:20:00 9.3 1.9 14.1 4.9 9.3 1.9 13.7 4.6 7.7 2 13.3 3.4 72 15 91 300 5.9 0 6 5.7 12/16/2005 18:30:00 8.6 1.8 14.1 3.8 8.7 1.9 14.1 3.8 7.5 1.7 12.6 3.4 68 15 78 300 6 0 6 6 12/16/2005 18:40:00 8.1 1.7 12.6 3.4 8.1 1.8 12.2 4.2 6.8 1.8 11.1 3 66 16 70 300 6 0 6.2 6 12/16/2005 18:50:00 9.2 2.1 14.5 3 9.2 2.2 14.1 2.6 7.8 2.2 14.1 3 68 16 82 300 6 0 6.2 6 12/16/2005 19:00:00 8.7 2.1 14.5 3.4 8.7 2.1 14.5 3.4 7.7 2 13 3 71 15 64 300 6.1 0 6.2 6 12/16/2005 19:10:00 9.2 1.9 14.1 3.8 9.2 2 14.1 4.2 7.7 2 13 3 69 15 74 300 5.7 0 6 5.7 12/16/2005 19:20:00 9.7 1.7 14.5 5.7 9.9 1.8 14.5 5.7 8.7 1.9 13.3 4.2 72 14 76 300 5.9 0 6 5.7 12/16/2005 19:30:00 9.4 2 14.9 4.2 9.4 2 14.9 4.9 8.4 2 14.9 4.6 79 13 77 300 6.1 0.1 6.5 6 12/16/2005 19:40:00 9.6 2.1 15.3 4.6 9.7 2.1 15.3 4.2 8.5 2.1 14.9 3.8 79 16 88 300 6.4 0 6.7 6.2 12/16/2005 19:50:00 10.1 2.1 16.4 5.3 10.2 2.1 16.4 5.7 9.1 1.9 14.5 4.9 78 12 84 300 6.6 0 6.7 6.2 12/16/2005 20:00:00 8.3 2 14.1 4.2 8.4 2 14.1 3.8 7.2 1.9 12.6 3.4 71 15 72 300 6.5 0 6.7 6.2 12/16/2005 20:10:00 7.2 1.9 12.2 2.3 7.2 1.9 11.8 2.3 6.1 1.7 11.5 1.9 61 15 82 300 5.9 0.2 6.5 5.7 12/16/2005 20:20:00 8.1 1.7 12.6 3.4 8.1 1.7 13 3.8 6.6 1.9 11.8 2.6 62 15 78 300 5.6 0 5.7 5.5 12/16/2005 20:30:00 8.7 2.1 14.1 4.9 8.7 2.2 14.1 4.6 7.3 2.5 14.9 2.6 63 14 88 300 5.7 0 6 5.5 12/16/2005 20:40:00 7.5 1.3 11.1 3.8 7.4 1.3 11.5 3.4 5.8 1.4 9.9 3 60 15 79 300 5.9 0 6 5.7 12/16/2005 20:50:00 7.6 1.7 11.8 3 7.5 1.7 11.8 2.3 5.8 1.5 9.9 1.9 57 15 55 300 6.1 0 6.2 6 12/16/2005 21:00:00 6.5 1.6 10.7 2.6 6.5 1.7 11.1 3 5.4 1.5 9.1 1.9 63 18 59 300 6.3 0 6.5 6.2 12/16/2005 21:10:00 5.6 1.3 9.1 1.5 5.5 1.5 9.1 1.5 4.5 1.3 8.4 1.5 59 17 45 300 6.5 0 6.7 6.2 12/16/2005 21:20:00 6.5 1.8 11.1 2.3 6.5 1.9 11.8 2.3 5.4 1.7 10.7 1.9 59 17 57 300 7.1 0.2 7.3 6.7 12/16/2005 21:30:00 7.4 1.7 11.8 3 7.4 1.8 11.8 2.6 6.3 1.7 10.7 2.3 63 16 51 300 7.3 0 7.5 7 12/16/2005 21:40:00 7.4 1.7 11.5 3.8 7.3 1.7 11.5 3.4 6 1.7 10.7 2.3 57 15 61 300 6.8 0 7.3 6.7 12/16/2005 21:50:00 7.1 1.6 10.7 3 6.8 1.7 10.7 2.3 5.3 1.6 9.9 1.1 47 15 51 300 6.6 0 6.7 6.5 12/16/2005 22:00:00 7.3 1.5 11.1 2.6 7 1.6 10.7 2.6 4.9 1.5 9.1 1.5 45 15 22 300 6.5 0 6.7 6.2 12/16/2005 22:10:00 7.9 1.3 11.5 4.2 7.6 1.5 11.5 3.8 5.8 1.6 9.9 1.9 45 12 30 300 6.4 0 6.7 6.2 12/16/2005 22:20:00 7.6 2.1 12.6 3 7.5 2.2 12.6 2.3 6.1 1.8 11.8 1.9 52 17 66 300 6.6 0.1 7 6.5 12/16/2005 22:30:00 7.4 1.2 11.5 4.6 7.1 1.4 11.1 3.8 5.6 1.6 10.7 1.5 46 16 66 300 6.6 0 7 6.2 12/16/2005 22:40:00 6.9 1.2 10.7 3.8 6.7 1.3 10.3 3 4.8 1.3 8 1.5 46 14 61 300 6.4 0 6.7 6.2 12/16/2005 22:50:00 7.3 1.5 11.8 3 7.1 1.6 12.2 2.6 5.2 1.7 11.1 1.9 49 17 51 300 6.6 0 6.7 6.5 12/16/2005 23:00:00 7.7 1.3 11.1 3.8 7.6 1.5 10.7 3.4 5.5 1.6 9.9 2.3 53 13 55 300 6.3 0 6.7 6.2 12/16/2005 23:10:00 7.5 1.6 11.8 3 7.4 1.7 12.2 3 5.6 1.5 10.7 2.6 57 14 73 300 6.3 0 6.5 6.2 12/16/2005 23:20:00 7.1 1.5 10.7 3.8 7.1 1.6 10.7 2.6 5.8 1.6 10.3 2.3 65 14 60 300 6.7 0 7 6.5 12/16/2005 23:30:00 5.7 1 8.8 3.4 5.8 1.1 8.8 3 4.9 1 7.6 1.9 62 15 60 300 6.8 0 7 6.7 12/16/2005 23:40:00 5.2 1.3 8.4 2.6 5.2 1.4 8.8 2.6 4.3 1.4 9.5 0.7 60 17 66 300 6.8 0 7 6.7 12/16/2005 23:50:00 5.1 1.3 9.9 2.3 5.2 1.3 9.9 2.3 4.6 1.2 8.8 2.3 75 17 97 300 7.3 0.1 7.5 7 12/17/2005 00:00:00 6.1 1.5 10.7 2.6 6.1 1.5 10.7 2.6 5.3 1.5 10.3 2.3 84 17 94 300 7.9 0.2 8.5 7.5 12/17/2005 00:10:00 4.2 1.3 8.8 1.9 4.1 1.3 8.4 1.5 3.7 1.3 8.4 1.5 131 51 100 300 8.2 0 8.5 8 12/17/2005 00:20:00 3.5 0.6 4.9 1.9 3.4 0.6 4.9 1.9 3.1 0.7 5.3 1.5 262 10 257 300 7.3 0.3 8 6.7 12/17/2005 00:30:00 2 0.6 3.8 0.4 1.8 0.7 3.4 0.4 1.9 0.6 3.4 0.7 276 18 252 300 6.8 0 7 6.7 12/17/2005 00:40:00 2.5 0.6 3.8 0.7 2.3 0.7 3.4 0.4 1.9 0.6 3.4 0.4 6 23 26 300 7 0 7.3 6.7 12/17/2005 00:50:00 1.6 0.7 3.8 0.4 1.4 0.8 3.4 0.4 1.3 0.6 3 0.4 28 28 90 300 7.3 0 7.3 7.3 12/17/2005 01:00:00 2.2 1.2 4.9 0.4 2 1.2 4.6 0.4 2 0.9 4.2 0.4 54 33 57 300 7.3 0 7.5 7.3 12/17/2005 01:10:00 2.1 1.3 5.7 0.4 2 1.3 5.3 0.4 1.6 1.2 4.9 0.4 131 38 97 300 7.1 0.2 7.3 6.7 12/17/2005 01:20:00 4.5 1.3 9.5 2.3 4.4 1.3 9.5 2.3 4 1.3 9.1 1.9 95 15 87 300 7.4 0.2 7.8 7 12/17/2005 01:30:00 2.6 0.8 4.9 0.7 2.6 0.8 4.9 0.7 2.4 0.6 4.2 1.1 83 15 68 300 7.3 0 7.5 7.3 12/17/2005 01:40:00 2.1 0.6 4.2 1.1 2.1 0.6 4.2 0.7 2 0.5 3.8 0.7 89 10 93 300 7 0.3 7.3 6.5 12/17/2005 01:50:00 2.8 0.5 4.2 1.5 2.8 0.5 4.2 1.5 2.6 0.5 4.2 1.5 95 9 94 300 6.7 0 6.7 6.5 12/17/2005 02:00:00 2.6 0.4 3.8 1.5 2.6 0.4 3.8 1.5 2.4 0.4 3.4 1.5 81 9 88 300 6.7 0 6.7 6.5 12/17/2005 02:10:00 2.4 0.3 3 1.5 2.3 0.4 3 0.7 2.1 0.4 3 1.1 98 13 91 300 6.5 0 6.7 6.2 12/17/2005 02:20:00 2.2 0.9 5.3 0.4 2 1 5.3 0.4 2 0.8 4.9 0.4 90 22 108 300 6.2 0 6.5 6.2 12/17/2005 02:30:00 4.1 0.8 6.8 1.5 4 0.9 6.5 1.1 3 1 5.3 0.7 61 14 76 300 6.6 0.1 7 6.2 12/17/2005 02:40:00 2.7 1 4.9 0.4 2.6 1.1 4.9 0.4 2 0.8 4.2 0.4 55 22 54 300 7.2 0.1 7.3 7 12/17/2005 02:50:00 4 1.4 7.6 0.7 3.9 1.5 8.4 0.4 3.2 1.2 7.2 0.4 61 16 57 300 7.3 0 7.5 7.3 12/17/2005 03:00:00 4.3 1.2 7.2 1.5 4.2 1.3 7.2 1.1 3.5 1 6.1 0.7 60 17 55 300 7.4 0 7.5 7.3 12/17/2005 03:10:00 5.8 1.4 10.7 3 5.8 1.5 11.1 3 4.8 1.3 9.5 1.9 71 15 65 300 7.7 0 7.8 7.5 12/17/2005 03:20:00 7.4 1.7 11.8 3 7.5 1.7 11.8 3 6.5 1.7 11.5 1.9 77 13 81 300 8 0 8.3 7.8 12/17/2005 03:30:00 8.4 1.9 14.9 3.8 8.5 1.9 14.9 3.8 7.5 1.8 12.6 3 75 15 76 300 8 0 8 7.8 12/17/2005 03:40:00 9.6 1.7 14.1 4.9 9.7 1.7 13.3 4.9 8.5 1.6 13 4.2 78 13 65 300 8.1 0 8.3 7.8 12/17/2005 03:50:00 9.6 1.7 14.1 4.9 9.7 1.7 14.9 4.9 8.7 1.7 14.1 5.3 81 12 98 300 8.1 0 8.3 8 12/17/2005 04:00:00 9 1.8 13.3 4.2 9 1.8 13.3 4.2 8.1 1.9 13.3 4.2 84 15 86 300 8 0 8.3 7.8 12/17/2005 04:10:00 7.9 1.7 12.2 4.2 7.9 1.7 12.2 4.2 7 1.7 11.8 3.4 78 15 96 300 7.8 0 8 7.8 12/17/2005 04:20:00 7.9 1.8 12.2 4.2 7.9 1.8 12.2 3.8 6.9 1.7 12.2 2.6 74 15 80 300 7.7 0 7.8 7.5 12/17/2005 04:30:00 7.5 1.7 13.3 4.6 7.6 1.7 12.6 4.2 6.6 1.5 12.2 3.4 76 15 100 300 7.8 0 7.8 7.8 12/17/2005 04:40:00 7.5 1.6 12.2 3.8 7.6 1.6 12.6 3.4 6.7 1.6 11.8 3.4 77 15 73 300 8 0.1 8.3 7.8 12/17/2005 04:50:00 7.4 1.3 10.7 3.8 7.5 1.3 10.7 3.4 6.6 1.5 10.7 3 78 13 98 300 8.1 0 8.3 7.8 12/17/2005 05:00:00 6.2 1.7 11.8 2.6 6.3 1.8 11.8 2.3 5.4 1.7 10.7 1.9 76 17 94 300 8.1 0 8.3 8 12/17/2005 05:10:00 4.3 1.3 8 1.5 4.3 1.4 8.8 1.5 3.8 1.2 7.6 1.5 82 22 71 300 8.1 0 8.3 8.3 12/17/2005 05:20:00 2.9 0.8 5.3 0.7 2.7 0.9 5.3 0.7 2.2 0.7 4.2 0.7 62 24 72 300 8 0 8.3 7.8 12/17/2005 05:30:00 2.7 0.7 4.9 1.1 2.5 0.8 5.3 0.7 2 0.6 3.8 0.7 44 28 86 300 7.8 0 7.8 7.5 12/17/2005 05:40:00 3.9 0.8 6.5 1.9 3.5 0.8 5.3 1.1 2.8 0.8 4.6 0.7 32 12 31 300 7.3 0 7.5 7.3 12/17/2005 05:50:00 3.6 0.9 6.1 1.5 3.5 1 6.1 1.5 3 0.9 5.7 1.1 59 17 44 300 7.3 0 7.5 7.3 12/17/2005 06:00:00 3 0.7 4.9 1.5 2.8 0.8 4.6 1.1 2.1 0.9 5.3 0.4 39 17 53 300 7.4 0 7.5 7.3 12/17/2005 06:10:00 3.8 1 6.5 1.5 3.7 1.1 6.8 1.5 3.4 1.2 6.8 0.7 67 20 88 300 7.5 0 7.8 7.3 12/17/2005 06:20:00 4.3 1.6 8.4 0.4 4.3 1.7 8.8 1.1 3.7 1.6 8.4 1.1 71 28 74 300 8.1 0.2 8.5 7.8 12/17/2005 06:30:00 4.1 1 6.8 1.5 3.7 1 6.5 1.1 3 1 5.3 0.7 29 15 34 300 7.6 0.3 8.5 7.3 12/17/2005 06:40:00 2.3 1 4.9 0.4 2.3 1.1 5.3 0.4 1.7 0.9 4.2 0.4 66 26 41 300 7.3 0 7.5 7.3 12/17/2005 06:50:00 2.9 0.9 4.9 0.4 2.8 1 5.3 0.4 2.4 1 4.9 0.4 80 17 91 300 7.7 0.2 8.3 7.3 12/17/2005 07:00:00 3 0.9 5.3 0.7 3 0.9 5.3 0.7 2.7 0.8 4.6 0.7 71 22 121 300 8 0 8.3 7.8 12/17/2005 07:10:00 4.3 1.9 9.5 1.1 4.3 2.1 10.3 0.7 3.8 1.8 8.4 0.7 71 21 98 300 8.1 0.1 8.5 8 12/17/2005 07:20:00 5.5 1.3 10.7 3 5.5 1.5 10.7 3 4.9 1.2 8.8 2.3 77 18 76 300 8.4 0 8.5 8.5 12/17/2005 07:30:00 4.4 1.1 7.2 2.3 4.4 1.2 7.6 1.9 3.5 1.1 6.8 1.5 61 18 59 300 8.4 0 8.5 8.3 12/17/2005 07:40:00 4.2 1 7.6 2.3 4.2 1 7.2 1.5 3.4 1 6.8 1.5 62 18 87 300 8.1 0 8.5 8 12/17/2005 07:50:00 4.5 1 7.2 1.9 4.5 1.2 7.2 1.5 3.6 1.2 6.5 0.7 63 18 73 300 8.1 0 8.3 8 12/17/2005 08:00:00 4.4 1.3 7.6 1.5 4.2 1.4 8 1.1 3.3 1.3 8 0.4 57 21 51 300 8 0 8.3 7.8 12/17/2005 08:10:00 3.8 1.1 6.1 0.7 3.5 1.1 6.1 0.7 2.5 1 5.7 0.7 33 22 26 300 7.7 0.2 8.3 7.3 12/17/2005 08:20:00 3.6 1 6.1 0.4 3.5 1 6.1 0.4 2.8 0.9 5.3 0.7 56 21 40 300 7.3 0 7.5 7.3 12/17/2005 08:30:00 4.6 1.2 8 1.9 4.7 1.2 8 1.9 4 1.1 7.2 1.5 71 17 67 300 7.9 0.2 8.3 7.5 12/17/2005 08:40:00 4.7 1.1 8 1.9 4.6 1.2 8.4 2.3 3.9 1.2 6.8 1.1 67 18 57 300 8.1 0 8.3 8 12/17/2005 08:50:00 4.2 1.1 6.8 1.1 4.1 1.2 6.5 1.1 3.3 1 6.1 1.1 55 17 59 300 8.2 0 8.3 8 12/17/2005 09:00:00 5.1 1.1 8.8 1.9 5 1.2 8.4 1.9 3.9 1.1 7.2 1.9 51 13 51 300 8 0 8.3 8 12/17/2005 09:10:00 5.6 1.1 8.8 2.3 5.6 1.2 9.1 1.9 4.6 1.2 8.4 2.3 63 15 64 300 7.8 0 8.3 7.8 12/17/2005 09:20:00 6.4 1.1 9.1 2.6 6.4 1.1 9.5 3 5 1.3 8.8 1.9 67 13 71 300 7.9 0 8.3 7.8 12/17/2005 09:30:00 6.4 1.3 10.3 3.4 6.5 1.3 10.3 3.4 5.2 1.4 9.1 2.3 67 15 81 300 8.1 0 8.3 8 12/17/2005 09:40:00 6.8 1.5 11.8 3.4 6.8 1.6 11.1 3 5.7 1.6 9.5 2.6 72 15 90 300 8.1 0 8.3 8 12/17/2005 09:50:00 7.8 1.7 12.6 3.8 7.8 1.7 12.2 3.4 6.6 1.7 11.1 2.6 76 13 66 300 8.1 0 8.3 8 12/17/2005 10:00:00 6.9 1.5 11.1 3 7 1.5 11.1 3 5.9 1.5 9.5 2.6 71 13 80 300 8.1 0 8.3 8 12/17/2005 10:10:00 6.6 1.5 10.3 3 6.7 1.5 10.3 3 5.9 1.4 9.9 2.6 78 14 94 300 8.2 0 8.5 8 12/17/2005 10:20:00 6.3 1.7 10.7 3 6.3 1.7 10.7 2.6 5.7 1.5 9.5 2.6 86 13 91 300 8.4 0 8.5 8.3 12/17/2005 10:30:00 6.3 1.3 10.7 3.8 6.3 1.4 10.7 3.8 5.7 1.5 9.9 3 90 12 81 300 8.5 0 8.8 8.5 12/17/2005 10:40:00 5.9 1.1 8.8 3.4 5.9 1.1 8.8 2.6 5.3 1 8.4 3 86 13 87 300 8.5 0 8.8 8.5 12/17/2005 10:50:00 2.8 0.7 5.3 1.5 2.7 0.7 4.6 0.7 2.4 0.7 4.6 0.4 160 35 105 300 6.4 1.2 8.5 4.8 12/17/2005 11:00:00 2 0.7 4.6 0.7 1.8 0.7 4.2 0.4 1.4 0.6 2.6 0.4 140 29 121 300 4.6 0.1 5 4.3 12/17/2005 11:10:00 1.4 0.4 2.6 0.4 1.1 0.5 2.6 0.4 1.1 0.4 1.9 0.4 135 13 157 300 4.3 0.2 4.5 4 12/17/2005 11:20:00 1.2 0.5 2.3 0.4 1 0.5 2.3 0.4 1 0.4 1.9 0.4 119 23 97 300 3.7 0.1 4 3.5 12/17/2005 11:30:00 0.9 0.4 2.3 0.4 0.6 0.4 1.9 0.4 0.7 0.5 2.3 0.4 151 58 151 300 3.6 0 3.8 3.5 12/17/2005 11:40:00 0.7 0.3 1.5 0.4 0.4 0.1 1.1 0.4 0.7 0.3 1.5 0.4 88 56 39 300 3.5 0 3.5 3.5 12/17/2005 11:50:00 1 0.6 2.6 0.4 0.9 0.6 2.6 0.4 1.2 0.5 2.3 0.4 123 53 142 300 3.6 0 3.8 3.5 12/17/2005 12:00:00 1.5 0.7 3.4 0.4 1.2 0.7 3 0.4 1.3 0.7 3.4 0.4 168 58 97 300 3.4 0 3.5 3.3 12/17/2005 12:10:00 1.6 0.5 2.6 0.4 1.4 0.5 2.6 0.4 1.6 0.4 2.6 0.7 174 26 181 300 3.3 0 3.5 3.3 12/17/2005 12:20:00 1.3 0.5 2.3 0.4 1 0.5 1.9 0.4 1.3 0.6 2.3 0.4 128 72 266 300 3.2 0 3.3 3.3 12/17/2005 12:30:00 0.9 0.7 3 0.4 0.8 0.6 3 0.4 0.9 0.6 2.6 0.4 307 64 58 300 3.4 0 3.5 3.3 12/17/2005 12:40:00 1 0.7 2.6 0.4 0.9 0.6 2.6 0.4 1 0.5 2.3 0.4 126 82 85 300 3.5 0 3.8 3.5 12/17/2005 12:50:00 2.3 0.4 3.4 1.5 2.1 0.5 3.4 1.1 1.8 0.5 3 0.7 51 12 64 300 4 0.3 4.5 3.5 12/17/2005 13:00:00 2.2 0.5 3.8 1.5 2 0.6 3.4 0.4 1.6 0.5 3 0.4 52 13 53 300 4.8 0.2 5.2 4.5 12/17/2005 13:10:00 0.8 0.6 2.6 0.4 0.6 0.5 2.3 0.4 1 0.6 2.3 0.4 107 82 34 300 4.9 0.4 5.5 4 12/17/2005 13:20:00 0.6 0.3 1.5 0.4 0.4 0.1 1.1 0.4 0.5 0.3 1.5 0.4 69 58 195 300 3.8 0.1 4.3 3.5 12/17/2005 13:30:00 2.5 0.6 4.6 1.1 2.3 0.7 4.6 0.4 1.8 0.7 4.6 0.4 48 12 64 300 3.6 0.2 4 3.5 12/17/2005 13:40:00 3.1 0.4 4.2 2.3 3 0.4 4.2 1.9 2.3 0.5 3.4 1.1 49 9 45 300 4.3 0.3 4.8 3.8 12/17/2005 13:50:00 3.4 0.6 4.9 1.1 3.3 0.6 4.9 1.5 2.4 0.8 4.2 0.7 54 11 43 300 5.4 0.3 5.7 4.8 12/17/2005 14:00:00 2.7 1 4.9 0.4 2.5 1 4.6 0.4 1.5 0.7 3.8 0.4 65 26 73 300 4.6 0.6 5.7 4 12/17/2005 14:10:00 3.7 1 5.3 0.7 3.6 1 5.3 0.7 2.7 0.9 4.9 0.7 64 13 65 300 4.9 0.7 5.7 3.8 12/17/2005 14:20:00 4.2 0.8 6.5 2.6 4.1 0.8 6.1 1.9 3 0.8 5.3 1.1 53 11 60 300 6 0 6.2 5.7 12/17/2005 14:30:00 4.3 0.8 6.5 2.3 4.2 0.8 6.1 1.9 3 1 6.8 1.1 53 13 57 300 6.3 0.1 6.7 6.2 12/17/2005 14:40:00 4.2 0.8 6.1 1.9 4.1 0.8 6.1 1.9 3.2 1 6.1 0.4 58 16 55 300 6.6 0 6.7 6.5 12/17/2005 14:50:00 3.7 0.8 6.1 1.1 3.6 0.9 5.7 1.1 3.1 0.9 5.3 1.5 76 22 79 300 6.7 0 7 6.7 12/17/2005 15:00:00 4 1.1 7.2 1.5 3.9 1.2 7.2 1.1 2.9 1.1 6.1 0.7 49 15 52 300 6.9 0 7 6.7 12/17/2005 15:10:00 3.8 1.1 8 0.7 3.6 1.2 8 0.4 2.7 1.2 6.8 0.4 45 22 49 300 6.8 0 7 6.7 12/17/2005 15:20:00 5.4 1 8 2.6 5.2 1.1 8.8 1.9 4 1.2 8.4 1.5 49 14 60 300 7.1 0 7.3 7 12/17/2005 15:30:00 4.8 1.1 7.6 1.5 4.7 1.2 7.2 1.5 3.8 1 6.8 1.5 50 15 42 300 7.1 0 7.3 7 12/17/2005 15:40:00 4 0.7 6.1 2.3 3.8 0.8 5.7 1.5 2.8 0.8 5.3 0.7 52 17 40 300 7.2 0 7.3 7 12/17/2005 15:50:00 4.4 1 7.2 1.1 4.2 1 7.2 1.1 3.1 1 5.7 1.1 45 16 48 300 6.9 0 7.3 6.7 12/17/2005 16:00:00 5.5 1.3 9.1 3 5.2 1.4 9.1 2.3 3.9 1.3 7.6 1.1 44 15 51 300 6.8 0 7 6.7 12/17/2005 16:10:00 5.7 1.2 8.4 2.3 5.7 1.2 8.8 2.3 4.3 1.3 8.4 1.5 52 15 56 300 7.1 0 7.3 7 12/17/2005 16:20:00 5.5 1.1 8 2.6 5.3 1.1 8 2.3 3.9 1.3 6.8 0.4 50 13 68 300 7.1 0 7.3 7 12/17/2005 16:30:00 4.9 1.1 8.4 1.9 4.7 1.2 8.4 1.5 3.5 1.1 7.2 1.1 47 17 63 300 7.1 0 7.3 7 12/17/2005 16:40:00 5.6 1.2 8.4 2.3 5.5 1.2 8 1.9 4.2 1.2 7.2 1.5 49 14 39 300 7.3 0 7.3 7 12/17/2005 16:50:00 5.8 1.1 8.8 3 5.6 1.2 8.8 2.6 4.5 1.4 8.4 1.1 51 14 52 300 7.4 0 7.5 7.3 12/17/2005 17:00:00 5.1 1.5 10.7 1.1 4.8 1.5 11.1 0.7 3.8 1.2 8.8 0.7 46 24 54 300 7.4 0.1 7.8 7.3 12/17/2005 17:10:00 4.4 0.7 6.1 1.9 4.3 0.8 6.1 1.1 3.5 0.8 6.1 1.5 48 17 43 300 6.8 0 7.3 6.7 12/17/2005 17:20:00 5 0.8 7.6 3 4.7 0.9 7.6 2.6 3.7 1 6.5 1.5 42 14 46 300 7 0 7.3 6.7 12/17/2005 17:30:00 5.4 1 8 2.3 5.2 1 8 1.5 4 1.2 8 1.1 50 13 48 300 7.1 0 7.3 7 12/17/2005 17:40:00 5.5 1.1 8.4 3 5.4 1.1 8.4 2.6 4.2 1.3 7.6 0.7 55 14 62 300 7.3 0 7.5 7.3 12/17/2005 17:50:00 6.1 1.3 9.5 2.3 6.1 1.3 9.1 2.3 5 1.2 8 2.3 59 14 59 300 7.6 0 7.8 7.3 12/17/2005 18:00:00 5.4 1.3 9.1 2.3 5.2 1.4 9.5 1.9 4.1 1.4 8 1.1 48 17 60 300 7.4 0.3 7.8 6.7 12/17/2005 18:10:00 4.7 1 7.2 2.3 4.5 1 7.2 2.3 3.6 0.9 6.8 1.5 43 15 52 300 6.7 0 7 6.7 12/17/2005 18:20:00 5.1 1.5 8.4 1.5 5 1.6 8.4 1.1 4 1.2 7.6 1.5 54 15 48 300 7 0 7.3 6.7 12/17/2005 18:30:00 5.8 1.7 10.7 2.3 5.8 1.9 10.7 1.9 4.7 1.7 9.9 1.1 69 19 96 300 7.3 0.2 7.8 7 12/17/2005 18:40:00 4.5 1.3 8 1.9 4.3 1.4 8 1.5 3.6 1.1 6.8 1.1 57 23 71 300 7.3 0.1 7.5 6.7 12/17/2005 18:50:00 4.8 0.7 6.8 3 4.4 0.8 6.8 2.6 3.3 0.8 6.1 1.5 34 12 45 300 6.4 0.2 7 6.2 12/17/2005 19:00:00 4.6 0.8 6.8 2.6 4.4 0.8 6.8 2.3 3.4 1 6.1 1.1 45 11 48 300 6.1 0 6.2 6 12/17/2005 19:10:00 4.8 1 7.6 2.3 4.6 1 7.6 1.9 3.6 1 6.5 1.5 44 12 59 300 5.9 0 6 5.7 12/17/2005 19:20:00 5 1.3 7.6 1.5 4.6 1.3 7.6 0.7 3.3 1.1 6.1 0.7 40 17 40 300 6 0 6.2 6 12/17/2005 19:30:00 6 1.2 8.4 2.6 5.5 1.2 8.4 2.6 4.1 1.2 7.2 1.1 39 14 34 300 6 0 6.2 5.7 12/17/2005 19:40:00 6.8 1.1 9.5 3 6.3 1.2 9.1 3 4.5 1.1 8 1.5 40 13 44 300 6.1 0 6.2 6 12/17/2005 19:50:00 7.5 1.2 10.7 4.2 7.2 1.4 10.7 3.4 5.1 1.4 9.1 1.9 43 11 35 300 6.1 0 6.2 6 12/17/2005 20:00:00 6.6 1.1 9.5 3 6.2 1.2 8.8 2.3 4.8 1.3 8.4 2.3 40 11 33 300 6.1 0 6.2 6 12/17/2005 20:10:00 6.9 1.1 9.9 3.8 6.6 1.2 9.9 3.4 4.7 1.2 8.8 1.9 42 11 43 300 5.7 0 6 5.7 12/17/2005 20:20:00 7.2 1.1 9.9 3.8 6.8 1.2 9.5 3 4.8 1.2 8.8 1.9 39 11 30 300 6 0 6.2 5.7 12/17/2005 20:30:00 7 1.2 10.3 3 6.5 1.3 9.9 3 4.8 1.3 8.8 1.5 38 13 37 300 6.2 0 6.2 6.2 12/17/2005 20:40:00 6.9 1.3 10.3 3.8 6.5 1.5 10.3 3 4.9 1.3 8 1.5 38 13 34 300 6.2 0 6.5 6.2 12/17/2005 20:50:00 6.5 1.2 9.5 3 5.8 1.2 8.8 3 4.7 1 7.6 1.9 35 13 28 300 6.2 0 6.5 6 12/17/2005 21:00:00 7.2 1 9.1 4.2 6.2 1 8.8 3.4 4.9 1 7.6 1.9 28 11 33 300 6.1 0 6.2 6 12/17/2005 21:10:00 7.2 1.2 9.9 4.2 6.3 1.1 9.5 3.4 4.9 1.2 8.4 1.9 30 12 45 300 6.1 0 6.2 6 12/17/2005 21:20:00 7 1.2 9.9 3.8 6.2 1.2 9.1 3 4.7 1.2 8 2.3 34 12 33 300 6.2 0 6.2 6 12/17/2005 21:30:00 7.1 1 10.3 4.6 6.3 1.2 9.1 3.4 4.8 1 8 2.6 33 10 24 300 6.3 0 6.5 6.2 12/17/2005 21:40:00 6.8 1.1 9.9 3.4 6 1.2 9.9 2.6 4.7 1 7.6 2.3 34 11 44 300 6.2 0 6.2 6 12/17/2005 21:50:00 6.2 1.1 8.4 2.6 5.6 1.2 8.4 2.3 4.2 1.2 7.2 1.1 38 13 42 300 5.9 0 6.2 5.7 12/17/2005 22:00:00 6.4 1 9.5 3 5.6 1.1 8.4 2.6 4.2 1.1 8 1.1 33 11 38 300 5.9 0 6 5.7 12/17/2005 22:10:00 6.4 0.9 8.8 3.4 6 1 8.8 3.4 4.4 1 7.2 1.9 40 11 37 300 5.9 0 6 5.7 12/17/2005 22:20:00 6.3 1 9.1 3.4 6 1.2 9.1 2.6 4.1 1.2 7.6 1.5 42 10 27 300 6.1 0 6.2 6 12/17/2005 22:30:00 5.5 1 8 2.6 5 1 7.6 1.5 3.8 0.9 6.5 1.9 37 10 31 300 6.2 0 6.2 6 12/17/2005 22:40:00 6 1 8.8 3.4 5.3 1.1 7.6 2.6 4.2 0.9 7.2 1.9 24 9 24 300 6 0 6.2 5.7 12/17/2005 22:50:00 6.4 1.1 8.4 2.3 6 1.2 8.8 1.5 4.7 1.1 7.6 1.9 17 12 42 300 5.7 0 6 5.7 12/17/2005 23:00:00 5.9 1 8 3.4 5.4 1.1 8 2.6 4.5 1 6.8 2.3 17 12 35 300 5.8 0 6 5.7 12/17/2005 23:10:00 6.4 0.8 8.4 4.2 5.5 0.9 8 3 4.4 0.9 7.2 1.9 23 9 16 300 5.7 0 6 5.7 12/17/2005 23:20:00 6 0.9 8 3.4 5.1 0.9 7.6 2.3 4.1 0.9 7.2 1.9 29 9 36 300 5.9 0 6 5.7 12/17/2005 23:30:00 5.1 0.8 7.2 3 4.5 0.8 6.8 2.6 3.6 0.7 5.7 1.5 29 12 16 300 5.8 0 6 5.7 12/17/2005 23:40:00 5.6 0.8 7.2 2.6 5 1 7.2 2.3 4 0.8 6.5 2.3 19 10 10 300 5.8 0 6 5.7 12/17/2005 23:50:00 5.4 0.8 7.2 3 4.7 0.8 7.2 2.3 3.4 0.8 5.3 0.7 22 10 20 300 5.9 0 6 5.7 12/18/2005 00:00:00 5.7 0.8 7.2 3 4.8 0.8 6.8 2.6 3.6 0.9 6.1 1.5 23 10 35 300 5.7 0 6 5.7 12/18/2005 00:10:00 3.7 0.8 6.1 1.9 3.2 0.7 5.7 1.5 2.1 0.8 4.9 0.4 29 14 39 300 5.3 0.1 5.7 5.2 12/18/2005 00:20:00 2.6 1.2 4.9 0.4 2.2 1 4.6 0.4 1.6 0.7 3.4 0.4 39 23 40 300 5.2 0 5.2 5 12/18/2005 00:30:00 1.1 0.6 2.6 0.4 0.9 0.6 2.6 0.4 0.9 0.5 2.3 0.4 304 86 353 300 5.1 0 5.2 5 12/18/2005 00:40:00 1.7 0.7 3.4 0.4 1.6 0.8 3.8 0.4 2 0.6 3.4 0.7 188 8 177 300 4.3 0.5 5.2 3.5 12/18/2005 00:50:00 1.6 0.4 2.6 0.7 1.7 0.5 2.6 0.4 1.5 0.4 2.3 0.4 210 15 214 300 3.1 0.2 3.5 2.8 12/18/2005 01:00:00 1.2 0.3 1.9 0.4 0.8 0.4 1.5 0.4 0.6 0.3 1.1 0.4 249 17 234 300 2.9 0 3.3 2.8 12/18/2005 01:10:00 0.7 0.3 1.1 0.4 0.4 0.1 0.7 0.4 0.6 0.3 1.1 0.4 259 14 278 300 2.7 0 2.8 2.6 12/18/2005 01:20:00 0.6 0.4 1.5 0.4 0.5 0.2 1.1 0.4 0.5 0.2 1.1 0.4 280 19 271 300 2.3 0 2.6 2.3 12/18/2005 01:30:00 0.6 0.3 1.1 0.4 0.4 0.1 1.1 0.4 0.7 0.3 1.5 0.4 7 12 345 300 2.4 0 2.6 2.3 12/18/2005 01:40:00 0.4 0.2 1.1 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 26 20 49 300 2.5 0 2.8 2.3 12/18/2005 01:50:00 1.6 0.7 3 0.4 1.4 0.7 3 0.4 1 0.5 2.3 0.4 50 9 52 300 2.7 0.1 2.8 2.6 12/18/2005 02:00:00 1.5 0.5 2.6 0.4 1.3 0.5 2.6 0.4 0.9 0.4 1.9 0.4 73 17 43 300 2.4 0.2 2.8 1.8 12/18/2005 02:10:00 1.1 0.5 2.3 0.4 0.8 0.6 2.3 0.4 0.7 0.4 1.9 0.4 102 6 94 300 1.7 0 1.8 1.6 12/18/2005 02:20:00 0.9 0.5 1.9 0.4 0.7 0.4 1.9 0.4 0.9 0.4 1.9 0.4 138 61 114 300 1.7 0 1.8 1.6 12/18/2005 02:30:00 2.4 0.5 3 1.1 2.3 0.6 3 0.7 1.7 0.4 2.6 0.7 52 9 48 300 1.8 0 1.8 1.6 12/18/2005 02:40:00 2 0.4 3.4 0.7 1.8 0.5 3 0.7 1.5 0.4 2.6 0.7 114 33 114 300 1.7 0 1.8 1.4 12/18/2005 02:50:00 1.3 0.4 1.9 0.4 1.1 0.4 1.9 0.4 0.8 0.3 1.5 0.4 123 18 104 300 1.5 0 1.6 1.4 12/18/2005 03:00:00 0.4 0.1 1.1 0.4 0.4 0 0.7 0.4 0.4 0.1 0.7 0.4 89 0 90 300 1.4 0 1.4 1.4 12/18/2005 03:10:00 0.8 0.7 3 0.4 0.7 0.6 3 0.4 0.5 0.3 1.1 0.4 69 22 40 300 1.4 0 1.4 1.4 12/18/2005 03:20:00 3.5 0.5 4.6 2.6 3.4 0.5 4.6 2.6 2 0.6 3.8 0.7 47 8 56 300 1.4 0 1.4 1.4 12/18/2005 03:30:00 3.8 1 5.7 0.7 3.7 1 5.7 0.7 2.5 1 4.6 0.4 62 7 52 300 1.7 0.1 1.8 1.4 12/18/2005 03:40:00 2.4 0.5 3.4 0.7 2.2 0.7 3.4 0.4 1 0.6 2.3 0.4 64 12 84 300 1.5 0.1 1.8 1.4 12/18/2005 03:50:00 2.9 0.5 4.2 1.9 2.8 0.5 4.2 1.9 1.8 0.4 3 1.1 79 6 79 300 1.3 0 1.4 1.4 12/18/2005 04:00:00 3.7 0.4 4.9 3 3.7 0.4 4.6 2.6 2.6 0.4 3.8 1.5 66 6 66 300 1.3 0 1.6 1.4 12/18/2005 04:10:00 3.7 0.4 4.6 3 3.7 0.4 4.6 2.6 2.8 0.4 3.8 1.5 57 5 53 300 1.7 0 1.8 1.4 12/18/2005 04:20:00 3.5 0.7 5.3 1.9 3.4 0.7 5.3 1.5 2.3 0.6 3.8 0.7 53 9 43 300 1.8 0 2.1 1.6 12/18/2005 04:30:00 3.1 0.6 4.9 1.9 2.9 0.6 4.9 1.9 2.1 0.4 3.4 0.7 50 10 35 300 2.3 0.2 2.6 1.8 12/18/2005 04:40:00 4.3 0.6 6.1 2.6 3.8 0.7 5.7 1.5 2.9 0.7 4.6 0.7 37 8 35 300 2.9 0.3 3.5 2.3 12/18/2005 04:50:00 2.7 1.2 5.3 0.4 2.4 1.1 4.9 0.4 2 0.6 4.2 0.7 68 49 33 300 3.3 0.6 4.3 2.3 12/18/2005 05:00:00 4.1 1.5 6.8 1.1 3.5 1.2 6.1 0.4 2.6 1.3 5.3 0.4 34 15 28 300 2.7 0.7 4.5 2.3 12/18/2005 05:10:00 5.2 0.8 7.2 2.3 4.6 0.9 6.5 1.9 3.7 0.8 5.7 1.5 21 10 20 300 5.8 0.5 6.2 4.5 12/18/2005 05:20:00 7.1 0.9 9.1 4.6 5.8 0.8 8 3.8 4.7 0.9 8 2.6 23 7 20 300 6.2 0 6.2 6.2 12/18/2005 05:30:00 4.4 1.7 8.8 1.1 3.7 1.5 7.6 0.4 2.8 1.1 5.7 0.4 44 30 23 300 6.1 0.1 6.2 5.5 12/18/2005 05:40:00 1.4 0.9 4.6 0.4 1.3 0.9 4.2 0.4 1.6 0.8 4.2 0.4 129 76 19 300 4 0.7 5.7 3 12/18/2005 05:50:00 3.5 1.2 6.5 0.7 3.1 1.2 6.1 0.4 2.2 1.1 4.9 0.4 37 22 41 300 3.3 0.6 4.8 2.8 12/18/2005 06:00:00 5.4 1.2 9.9 2.6 5 1.2 8.4 2.3 4 1.1 6.8 1.5 44 17 24 300 6 0.5 6.7 4.8 12/18/2005 06:10:00 6 1 8.8 3.4 5.6 1 8.4 3 4.4 1 7.6 1.9 41 13 46 300 7 0.1 7.3 6.7 12/18/2005 06:20:00 6 1.1 9.1 3 5.4 1.1 8.4 2.6 4.4 1 7.6 2.3 31 13 34 300 7.4 0 7.5 7.3 12/18/2005 06:30:00 6.6 1.4 9.9 3 5.9 1.3 9.1 3 4.8 1.3 7.6 1.9 30 13 39 300 7.4 0 7.5 7.3 12/18/2005 06:40:00 6.1 1.3 9.1 2.6 5.6 1.4 9.1 2.3 4.4 1.1 7.6 2.3 38 14 54 300 7.4 0 7.5 7.3 12/18/2005 06:50:00 6.1 1.1 9.5 3 5.3 1.1 9.5 1.9 4.6 1 8.4 2.6 32 11 59 300 7.5 0 7.8 7.3 12/18/2005 07:00:00 6.2 0.8 8 3.8 5.4 0.9 7.6 3 4.5 0.8 7.6 2.3 22 10 32 300 7.3 0 7.5 7.3 12/18/2005 07:10:00 6.4 0.9 9.1 4.2 5.6 1 8.4 3.4 4.7 0.9 7.6 2.3 23 9 14 300 7.1 0 7.3 7 12/18/2005 07:20:00 6 1.1 8.4 3 5.1 1.1 8 2.3 4.3 1 7.6 1.9 26 10 20 300 6.9 0 7 7 12/18/2005 07:30:00 4.6 0.8 6.5 2.3 4.2 0.8 6.1 1.9 3.6 0.8 6.1 1.9 39 11 40 300 7 0 7.3 7 12/18/2005 07:40:00 5.2 1.1 8.4 2.6 4.9 1.1 8.4 2.3 3.8 1.2 7.2 0.7 43 13 37 300 7.1 0 7.3 7 12/18/2005 07:50:00 4.5 1.3 7.6 0.4 4.3 1.2 7.2 0.7 3.3 1.1 6.5 1.1 47 19 15 300 7.3 0 7.5 7.3 12/18/2005 08:00:00 5.1 1.1 7.6 1.9 4.7 1.1 7.6 1.9 3.4 1.3 6.5 0.4 40 17 28 300 7.3 0 7.5 7.3 12/18/2005 08:10:00 6.5 1.2 9.5 4.2 5.7 1.1 8.8 3.4 4.6 1.1 7.2 1.9 29 11 28 300 7.2 0 7.5 7 12/18/2005 08:20:00 7 1.1 9.5 4.2 6.1 1.1 8.8 3 5.2 1.1 8.8 2.3 23 9 39 300 7.3 0 7.3 7.3 12/18/2005 08:30:00 7.2 1 9.5 4.2 6.2 1 9.1 3.4 5.2 1 8.4 2.6 24 10 17 300 7.2 0 7.3 7.3 12/18/2005 08:40:00 7.1 1.1 9.1 4.2 6.3 1 8.8 3.8 5.3 1 7.6 2.3 30 13 31 300 7.2 0 7.3 7 12/18/2005 08:50:00 4.9 1.3 7.6 1.1 4.7 1.3 8 1.1 3.7 1.3 7.2 0.7 47 21 49 300 7.3 0 7.3 7.3 12/18/2005 09:00:00 3.5 1.1 6.5 0.7 3.3 1.2 6.1 0.4 2.5 1.1 5.7 0.4 61 29 64 300 4.9 1.4 7.3 3.5 12/18/2005 09:10:00 2.4 0.6 5.3 0.7 2.4 0.6 4.9 0.4 2.2 0.6 3.8 0.4 159 51 76 300 2.9 0.7 4 1.8 12/18/2005 09:20:00 1.7 0.8 3.4 0.4 1.6 0.8 3.4 0.4 1.7 0.7 3.4 0.4 167 33 193 300 1.7 0 1.8 1.6 12/18/2005 09:30:00 0.8 0.5 2.3 0.4 0.8 0.6 2.6 0.4 0.9 0.6 2.3 0.4 142 66 100 300 1.7 0 1.8 1.6 12/18/2005 09:40:00 0.8 0.5 2.3 0.4 0.7 0.6 2.6 0.4 1 0.7 2.6 0.4 85 98 16 300 1.8 0 1.8 1.6 12/18/2005 09:50:00 0.6 0.4 1.9 0.4 0.5 0.4 1.9 0.4 0.8 0.6 2.6 0.4 286 98 15 300 1.7 0 1.8 1.6 12/18/2005 10:00:00 0.6 0.4 1.9 0.4 0.5 0.3 1.9 0.4 0.7 0.4 2.3 0.4 97 107 10 300 1.7 0 1.8 1.4 12/18/2005 10:10:00 1 0.6 2.6 0.4 0.8 0.6 2.6 0.4 0.6 0.3 1.9 0.4 19 53 31 300 1.4 0 1.6 1.4 12/18/2005 10:20:00 1.4 0.7 3.4 0.4 1.2 0.8 3.4 0.4 1.5 0.8 3.4 0.4 149 36 185 300 1.1 0 1.4 0.9 12/18/2005 10:30:00 1.2 0.6 3 0.4 1 0.6 3 0.4 1.2 0.6 3 0.4 161 39 190 300 0.9 0 0.9 0.9 12/18/2005 10:40:00 1.3 0.7 3 0.4 1.2 0.8 3 0.4 1.2 0.7 2.6 0.4 185 22 185 300 0.9 0 0.9 0.9 12/18/2005 10:50:00 1.6 0.7 3 0.4 1.5 0.8 3 0.4 1.7 0.5 2.6 0.4 188 21 185 300 0.9 0 0.9 0.9 12/18/2005 11:00:00 1.6 0.6 3 0.4 1.5 0.7 3 0.4 1.5 0.4 2.6 0.4 191 13 190 300 0.8 0 0.9 0.9 12/18/2005 11:10:00 2.1 0.5 3.8 1.1 2.1 0.5 3.8 1.1 1.5 0.4 2.6 0.7 205 15 226 300 0.8 0 0.9 0.9 12/18/2005 11:20:00 1.7 1 4.2 0.4 1.5 1 4.2 0.4 1.7 0.8 3.8 0.4 224 69 222 300 1.1 0 1.4 0.9 12/18/2005 11:30:00 1.5 0.8 3.4 0.4 1.3 0.9 3.4 0.4 1.3 0.8 3.8 0.4 109 82 153 300 0.9 0 1.4 0.9 12/18/2005 11:40:00 1.4 0.7 2.6 0.4 1.2 0.6 2.3 0.4 1.1 0.6 2.6 0.4 118 56 32 300 0.9 0 1.1 0.9 12/18/2005 11:50:00 1.2 0.7 2.6 0.4 1.2 0.7 2.6 0.4 1.4 0.6 2.6 0.4 171 36 174 300 0.9 0 1.1 0.9 12/18/2005 12:00:00 0.9 0.5 2.3 0.4 0.8 0.5 1.9 0.4 0.9 0.6 2.3 0.4 188 47 80 300 1.2 0 1.4 0.9 12/18/2005 12:10:00 1.3 0.8 3 0.4 1.2 0.9 3 0.4 1.7 0.8 3 0.4 117 86 215 300 1.1 0 1.4 0.9 12/18/2005 12:20:00 1.2 0.5 2.3 0.4 1 0.5 2.3 0.4 0.7 0.5 2.3 0.4 61 51 74 300 1.2 0 1.4 0.9 12/18/2005 12:30:00 1 0.6 3 0.4 0.9 0.6 2.6 0.4 1.6 0.5 3 0.4 190 26 161 300 1.2 0 1.4 1.1 12/18/2005 12:40:00 1.9 0.8 3.4 0.4 1.8 0.9 3.4 0.4 2.1 0.4 3 0.7 222 7 220 300 1.2 0 1.4 1.4 12/18/2005 12:50:00 2.9 0.4 3.8 1.9 2.8 0.5 3.4 1.5 2.3 0.4 3 1.1 228 7 222 300 1.2 0 1.4 1.4 12/18/2005 13:00:00 1.6 0.5 2.6 0.4 1.3 0.6 2.3 0.4 1.7 0.5 2.6 0.7 260 16 251 300 1.2 0 1.4 1.1 12/18/2005 13:10:00 1.3 0.6 2.3 0.4 1.1 0.6 2.3 0.4 1.6 0.5 2.3 0.4 238 19 239 300 1.3 0 1.6 1.1 12/18/2005 13:20:00 0.6 0.3 1.5 0.4 0.4 0.2 1.5 0.4 1.3 0.4 2.3 0.4 243 11 242 300 1.4 0 1.6 1.4 12/18/2005 13:30:00 2 0.5 3 0.4 2.4 0.7 3.8 0.4 1.8 0.8 3.4 0.4 208 4 208 300 1.4 0 1.6 1.4 12/18/2005 13:40:00 2.1 0.3 3 1.1 2.3 0.4 3.4 1.5 1.6 0.4 2.6 0.4 218 6 214 300 1.4 0 1.6 1.4 12/18/2005 13:50:00 2.2 0.5 3 0.7 2 0.6 3 0.4 1.1 0.6 2.3 0.4 243 13 233 300 1.4 0 1.6 1.4 12/18/2005 14:00:00 1.1 0.6 2.6 0.4 0.8 0.6 2.6 0.4 1.3 0.5 2.6 0.4 265 56 259 300 1.5 0 1.6 1.4 12/18/2005 14:10:00 0.5 0.2 1.5 0.4 0.4 0.1 1.1 0.4 0.4 0.2 1.1 0.4 134 56 149 300 1.5 0 1.6 1.4 12/18/2005 14:20:00 0.4 0.2 1.5 0.4 0.4 0.2 1.1 0.4 0.4 0.2 1.1 0.4 127 21 149 300 1.3 0 1.6 1.4 12/18/2005 14:30:00 0.5 0.3 1.9 0.4 0.4 0.2 1.5 0.4 0.4 0.1 1.1 0.4 134 45 92 300 1.2 0 1.4 1.1 12/18/2005 14:40:00 0.6 0.5 2.3 0.4 0.6 0.5 2.3 0.4 0.4 0 0.7 0.4 126 47 62 300 1.3 0 1.4 1.4 12/18/2005 14:50:00 1.3 0.9 3.8 0.4 1.1 0.8 3.4 0.4 0.7 0.6 3 0.4 55 26 24 300 1.3 0 1.6 1.4 12/18/2005 15:00:00 2.7 0.7 4.9 1.5 2.4 0.8 4.9 1.1 1.5 0.7 3.8 0.4 38 9 52 300 1.6 0.2 2.3 1.4 12/18/2005 15:10:00 3 0.6 5.3 1.5 2.8 0.6 4.9 1.1 1.8 0.5 3.4 0.7 45 15 46 300 2.3 0 2.6 2.1 12/18/2005 15:20:00 3.5 0.8 5.7 1.5 3.2 0.9 5.7 1.1 1.8 0.6 3.8 0.4 41 15 55 300 2.4 0 2.6 2.1 12/18/2005 15:30:00 2.4 1 5.3 0.4 2.2 1 4.6 0.4 1.8 0.8 3.8 0.4 74 49 16 300 2 0.3 2.6 1.4 12/18/2005 15:40:00 2.7 0.8 5.3 0.7 2.3 0.8 4.9 0.7 1 0.6 2.6 0.4 35 20 36 300 1.4 0.1 1.8 1.4 12/18/2005 15:50:00 3.8 1 7.2 1.1 3.5 1.1 7.6 1.5 2.5 1.1 6.1 0.4 22 15 13 300 1.6 0.8 3.8 0.9 12/18/2005 16:00:00 3.7 1.1 6.1 0.7 3.4 1.1 6.1 0.4 3.1 0.8 6.5 0.7 43 30 26 300 4.9 0.8 6 3.3 12/18/2005 16:10:00 3.6 1 6.8 1.9 3.4 0.9 6.1 1.5 2.6 0.8 5.3 0.4 56 21 52 300 2.1 0.4 3.3 1.6 12/18/2005 16:20:00 5.7 1.3 9.1 2.3 5.1 1.3 9.1 1.9 4.1 1.3 8.8 1.5 28 15 41 300 4.3 1.3 6.2 2.6 12/18/2005 16:30:00 5.8 1 8.8 3 5.1 1 8 2.3 4.3 1 7.6 2.3 26 13 18 300 6.6 0 6.7 6.2 12/18/2005 16:40:00 6.5 1 8.8 3 5.8 1 8.8 2.6 4.9 0.9 7.2 2.6 24 11 11 300 6.5 0 6.7 6.5 12/18/2005 16:50:00 5.8 1 8.8 3.4 5.4 0.8 8 3.4 4.6 0.8 6.8 2.3 33 18 23 300 6.7 0 7 6.5 12/18/2005 17:00:00 5.5 1.3 8.4 2.6 5 1.3 8 1.9 4.2 1.1 7.6 1.9 24 15 22 300 6.7 0 7 6.7 12/18/2005 17:10:00 6.9 1.1 9.9 4.2 6.3 1.2 10.3 3.4 5.2 1.2 8.8 2.3 19 10 17 300 6.7 0 7 6.7 12/18/2005 17:20:00 5.9 1 8.4 2.3 5.3 1 8.4 1.9 4.4 1 7.2 1.5 22 12 31 300 6.8 0 7 6.7 12/18/2005 17:30:00 6.1 0.9 8.8 3.4 5.3 0.9 7.6 2.3 4.4 0.9 7.2 2.3 23 9 19 300 6.7 0 7 6.5 12/18/2005 17:40:00 5.9 0.9 8 3.8 5.3 1 8.4 3.4 4.5 0.9 7.2 2.3 26 12 3 300 6.7 0 6.7 6.5 12/18/2005 17:50:00 6 1.1 8.8 3.4 5.3 1.1 8.4 3 4.4 1 7.6 1.9 26 11 24 300 6.6 0 6.7 6.5 12/18/2005 18:00:00 3.9 1.1 7.2 1.1 3.6 1.1 6.8 1.1 2.8 1 6.1 0.4 43 24 44 300 6.1 0.9 6.7 4.3 12/18/2005 18:10:00 2.5 1.2 5.7 0.4 2.4 1.1 5.3 0.4 2.2 0.6 4.2 0.7 84 49 30 300 3.4 1.3 5 1.4 12/18/2005 18:20:00 1.9 0.7 3 0.4 1.8 0.7 3 0.4 2.2 0.5 3.4 0.4 148 32 125 300 0.9 0.2 1.6 0.7 12/18/2005 18:30:00 1.9 0.7 3.8 0.4 2 0.8 3.4 0.4 2.2 0.5 3.4 0.7 200 32 223 300 0.6 0 0.7 0.4 12/18/2005 18:40:00 1.6 0.9 4.2 0.4 1.6 1 4.2 0.4 1.7 0.9 4.2 0.4 259 98 139 300 0.7 0 0.7 0.7 12/18/2005 18:50:00 1.4 0.4 2.3 0.4 1.4 0.5 2.3 0.4 1.6 0.5 3 0.4 186 61 358 300 0.7 0 0.7 0.7 12/18/2005 19:00:00 1.5 0.7 2.6 0.4 1.5 0.6 2.6 0.4 1.7 0.4 2.6 0.7 213 15 226 300 0.6 0 0.7 0.2 12/18/2005 19:10:00 0.9 0.4 1.9 0.4 0.7 0.5 2.3 0.4 0.7 0.5 2.3 0.4 226 35 178 300 0.2 0 0.4 0.2 12/18/2005 19:20:00 0.7 0.4 1.9 0.4 0.7 0.4 1.9 0.4 1 0.4 1.9 0.4 208 36 191 300 0.1 0 0.2 0.2 12/18/2005 19:30:00 1.4 0.3 2.3 0.7 1.3 0.3 1.9 0.7 1.2 0.4 1.9 0.4 216 11 221 300 0.1 0 0.2 -0.1 12/18/2005 19:40:00 1.5 0.3 2.3 0.7 1.6 0.3 2.3 1.1 1.3 0.3 2.3 0.7 214 8 213 300 0 0 0.2 -0.1 12/18/2005 19:50:00 1.8 0.4 2.6 0.7 1.6 0.4 2.3 0.4 1.1 0.3 1.9 0.4 244 15 237 300 -0.2 0 0.2 -0.3 12/18/2005 20:00:00 1.3 0.5 2.3 0.4 1.2 0.4 1.9 0.4 0.9 0.5 2.3 0.4 220 24 270 300 0 0 0.2 -0.1 12/18/2005 20:10:00 1.7 0.4 3 0.7 1.8 0.4 3 1.1 1.5 0.4 2.3 0.4 220 15 226 300 0.1 0 0.2 -0.1 12/18/2005 20:20:00 1 0.7 2.6 0.4 0.8 0.7 2.6 0.4 1.4 0.6 2.6 0.4 240 9 227 300 0.2 0 0.4 0.2 12/18/2005 20:30:00 1.2 0.6 2.6 0.4 1 0.5 2.3 0.4 0.8 0.4 1.9 0.4 25 51 38 300 0.2 0 0.4 0.2 12/18/2005 20:40:00 1.7 0.5 3 0.7 1.6 0.5 3 0.4 0.5 0.2 1.5 0.4 60 17 38 300 0.2 0 0.4 0.2 12/18/2005 20:50:00 2.2 1.5 5.7 0.4 2 1.3 4.9 0.4 1.2 0.9 3.8 0.4 71 41 18 300 0.4 0.1 0.9 0.2 12/18/2005 21:00:00 3.3 0.8 5.7 1.1 2.9 0.8 5.3 0.7 2 0.7 3.8 0.4 37 17 40 300 0.9 0.3 1.8 0.7 12/18/2005 21:10:00 3.1 1.2 6.1 0.4 2.8 1.2 6.8 0.4 2.1 1 4.9 0.4 23 41 41 300 2.6 0.4 3.3 1.8 12/18/2005 21:20:00 3.4 1.3 8 0.7 3.1 1.3 8.4 0.4 2.6 1.1 6.5 0.4 41 30 49 300 3.6 0.6 4.3 2.8 12/18/2005 21:30:00 4.2 1.5 9.1 0.4 3.9 1.5 9.9 0.4 3 1.3 7.2 0.4 38 22 14 300 4.6 0.3 5.2 4.3 12/18/2005 21:40:00 4.8 1.5 8.8 1.1 4.4 1.4 9.1 1.1 3.5 1.1 8 1.1 32 19 6 300 5.3 0 5.5 5 12/18/2005 21:50:00 2.5 0.8 4.6 0.4 2.4 0.8 4.6 0.4 2.4 0.7 4.2 0.7 121 66 37 300 3.2 1.6 5.5 1.1 12/18/2005 22:00:00 2.6 0.9 4.9 0.4 2.5 0.8 5.3 0.4 2.3 0.7 4.2 0.4 108 69 56 300 0.5 0.1 1.1 0.2 12/18/2005 22:10:00 2 0.7 4.2 0.4 1.9 0.8 4.2 0.4 1.7 0.7 4.2 0.4 82 35 104 300 0.5 0.1 0.7 0.2 12/18/2005 22:20:00 2.8 1 4.9 0.4 2.9 1.1 4.9 0.7 2.8 0.6 4.6 1.1 202 23 220 300 0.2 0.1 0.7 0.2 12/18/2005 22:30:00 1.9 0.6 3.4 0.4 1.8 0.6 3.4 0.4 2.3 0.7 3.4 0.4 298 39 226 300 0.4 0.1 0.7 0.2 12/18/2005 22:40:00 0.8 0.5 1.9 0.4 0.7 0.4 1.9 0.4 1.6 0.5 2.6 0.4 266 35 260 300 0.6 0.1 0.9 0.2 12/18/2005 22:50:00 0.9 0.5 2.3 0.4 0.9 0.5 2.3 0.4 1.6 0.5 2.6 0.4 200 18 223 300 0.6 0 0.7 0.2 12/18/2005 23:00:00 0.5 0.3 1.5 0.4 0.4 0.2 1.5 0.4 0.6 0.3 1.5 0.4 104 56 73 300 0.4 0 0.7 0.2 12/18/2005 23:10:00 1.4 0.4 2.3 0.4 1.2 0.5 2.3 0.4 1.4 0.5 2.6 0.4 114 32 151 300 0.2 0 0.4 0.2 12/18/2005 23:20:00 2 0.4 3.4 1.1 2.1 0.4 3 1.1 1.9 0.5 2.6 0.4 186 21 187 300 0.1 0 0.2 -0.1 12/18/2005 23:30:00 1 0.6 2.3 0.4 0.9 0.5 2.6 0.4 1.1 0.4 1.9 0.4 257 69 220 300 0 0 0.2 -0.1 12/18/2005 23:40:00 2.2 1.3 5.3 0.4 1.9 1.2 4.6 0.4 1.1 1 3.4 0.4 26 22 31 300 0 0.1 0.7 -0.1 12/18/2005 23:50:00 3.3 1.1 6.1 1.1 3 1 5.7 0.7 2.1 0.8 4.6 0.7 35 19 24 300 1.3 0.4 1.8 0.7 12/19/2005 00:00:00 2.9 0.6 5.3 1.1 2.9 0.6 4.9 1.1 2.4 0.5 3.8 1.1 75 19 61 300 0.9 0.4 1.8 0.4 12/19/2005 00:10:00 2.8 0.6 4.2 1.5 2.8 0.6 4.2 1.1 2.2 0.7 3.4 0.7 93 36 60 300 0.5 0 0.7 0.2 12/19/2005 00:20:00 1.9 0.4 3.4 1.1 1.8 0.4 3 0.7 2 0.3 2.6 1.1 138 22 82 300 0.3 0 0.4 0.2 12/19/2005 00:30:00 1.5 0.4 2.3 0.4 1.3 0.5 2.3 0.4 1.3 0.6 2.3 0.4 187 21 174 300 0.2 0 0.4 0.2 12/19/2005 00:40:00 0.9 0.7 3.8 0.4 0.7 0.6 3.8 0.4 0.8 0.3 1.5 0.4 291 86 16 300 0.1 0 0.2 -0.1 12/19/2005 00:50:00 3.4 0.9 5.7 1.5 3.1 0.8 5.3 1.5 2 0.8 4.2 0.7 36 7 39 300 0.2 0 0.4 0.2 12/19/2005 01:00:00 3.1 0.9 4.6 0.7 3 0.9 4.9 0.4 2 0.7 3.8 0.4 52 18 44 300 0.4 0 0.7 0.2 12/19/2005 01:10:00 2.9 1.2 5.7 0.4 2.8 1.2 6.1 0.4 2 1 4.9 0.4 56 23 53 300 0.9 0.4 2.3 0.2 12/19/2005 01:20:00 5.8 1.4 9.9 2.6 5.4 1.4 9.5 2.3 4.4 1.3 8.4 1.1 37 15 35 300 4.3 1 5.7 2.3 12/19/2005 01:30:00 6.5 1.2 9.9 3.4 5.8 1.3 10.3 3 5 1 8.4 2.6 35 14 43 300 5.9 0 6.2 5.5 12/19/2005 01:40:00 5.7 1.2 9.1 2.6 5.3 1.3 9.1 1.9 4.1 1.3 8 1.1 42 15 54 300 6.2 0 6.2 6 12/19/2005 01:50:00 3.2 1.2 7.2 0.4 3.2 1 6.5 0.7 2.8 0.7 4.9 1.1 114 76 18 300 4.6 1.4 6.2 2.1 12/19/2005 02:00:00 2.3 0.6 3.8 0.7 2.4 0.6 3.8 0.7 2.5 0.6 3.8 1.1 192 19 198 300 1.4 0.2 2.1 1.1 12/19/2005 02:10:00 1.3 0.8 3 0.4 1.2 0.8 3 0.4 1.1 0.7 3 0.4 89 79 236 300 1.3 0.2 1.8 0.9 12/19/2005 02:20:00 1.1 0.7 2.6 0.4 1.1 0.7 2.6 0.4 1.6 0.7 3.4 0.4 135 66 195 300 1.4 0 1.6 1.4 12/19/2005 02:30:00 2.6 0.5 3.4 1.1 2.7 0.4 3.4 1.1 2.5 0.5 3.4 0.4 192 6 187 300 1.1 0.1 1.4 0.7 12/19/2005 02:40:00 2.6 0.6 3.4 0.4 2.5 0.6 3.4 0.4 1.8 0.7 3.4 0.4 222 4 223 300 0.2 0.2 0.7 -0.1 12/19/2005 02:50:00 2.1 0.5 3 0.4 2 0.5 3 0.4 1.8 0.6 2.6 0.4 252 22 224 300 0 0.1 0.2 -0.1 12/19/2005 03:00:00 1.1 0.5 2.3 0.4 0.9 0.5 2.6 0.4 1.6 0.5 2.6 0.4 238 17 246 300 0 0.1 0.2 -0.3 12/19/2005 03:10:00 1.9 0.4 2.6 1.1 2.2 0.3 3 1.5 2.3 0.3 3 1.5 203 8 189 300 -0.4 0 -0.1 -0.5 12/19/2005 03:20:00 1.4 0.6 2.6 0.4 1.5 0.6 2.6 0.4 1.3 0.6 2.6 0.4 206 26 222 300 -0.8 0.1 -0.5 -1 12/19/2005 03:30:00 1.1 0.5 2.3 0.4 1.1 0.5 2.3 0.4 1.1 0.6 2.6 0.4 176 56 191 300 -0.7 0 -0.5 -1 12/19/2005 03:40:00 2.1 1 4.6 0.4 2.1 1.1 4.6 0.4 2 0.7 4.2 0.4 57 14 55 300 -0.4 0 -0.3 -0.5 12/19/2005 03:50:00 1.9 0.8 3.8 0.4 1.9 0.8 3.8 0.4 1.4 0.4 2.3 0.4 93 41 51 300 -0.4 0 -0.3 -0.5 12/19/2005 04:00:00 1.9 0.7 3.4 0.4 1.8 0.7 3.4 0.4 1 0.5 2.3 0.4 56 24 46 300 -0.4 0 -0.3 -0.5 12/19/2005 04:10:00 2.6 1.1 6.1 0.7 2.5 1 5.3 0.7 1.7 0.8 3.8 0.4 49 11 37 300 -0.3 0.2 0.2 -0.5 12/19/2005 04:20:00 4.5 0.8 6.8 2.6 4.4 0.8 6.8 2.6 3.3 0.8 5.3 1.9 44 10 40 300 1.2 0.9 2.8 0.2 12/19/2005 04:30:00 2.4 1.2 6.5 0.4 2.4 1.1 5.7 0.4 2.2 0.8 4.6 0.4 132 64 30 300 1 1.2 2.8 -0.5 12/19/2005 04:40:00 2.2 0.7 3.8 0.4 2.2 0.7 3.8 0.4 2.6 0.7 4.2 1.1 132 24 161 300 -0.8 0.1 -0.5 -1 12/19/2005 04:50:00 1.5 0.5 2.6 0.4 1.5 0.5 2.6 0.4 2 0.3 2.6 1.5 179 33 179 300 -0.9 0 -0.7 -1 12/19/2005 05:00:00 1.7 0.5 3 0.4 1.8 0.6 2.6 0.4 2 0.3 2.6 1.1 217 9 215 300 -1 0 -0.7 -1.2 12/19/2005 05:10:00 1.3 0.2 1.9 0.7 1.2 0.3 1.9 0.7 0.8 0.5 2.3 0.4 145 35 203 300 -1 0 -0.7 -1.2 12/19/2005 05:20:00 2 0.7 3.8 0.4 2 0.8 3.8 0.4 1 0.6 2.3 0.4 72 22 64 300 -1 0 -0.7 -1.2 12/19/2005 05:30:00 2.1 0.7 3.4 0.7 2 0.8 3.4 0.4 0.8 0.5 2.3 0.4 71 20 64 300 -0.8 0.1 -0.5 -1 12/19/2005 05:40:00 1.1 0.3 1.9 0.4 1 0.4 1.9 0.4 1.3 0.3 1.9 0.4 173 14 160 300 -0.3 0.1 -0.1 -0.5 12/19/2005 05:50:00 1.9 0.6 3 0.4 1.8 0.6 2.6 0.4 1.9 0.6 3 0.4 224 27 245 300 -0.2 0 -0.1 -0.5 12/19/2005 06:00:00 1.4 0.7 3.8 0.4 1.3 0.8 3.8 0.4 1.3 0.5 3 0.4 270 47 256 300 -0.2 0 -0.1 -0.5 12/19/2005 06:10:00 2.3 0.5 3.8 1.5 2.2 0.6 3.8 1.1 2.2 0.3 3 1.5 249 7 261 300 0 0.2 0.4 -0.1 12/19/2005 06:20:00 1.9 0.3 2.6 1.5 1.7 0.3 2.6 1.1 1.5 0.5 2.6 0.4 236 4 241 300 0 0.3 0.4 -0.5 12/19/2005 06:30:00 1.9 0.5 3 0.7 1.8 0.5 3 0.4 1.3 0.5 2.3 0.4 246 17 237 300 -0.6 0 -0.5 -0.7 12/19/2005 06:40:00 1.3 0.8 3 0.4 1.2 0.8 3 0.4 1 0.6 2.6 0.4 228 26 245 300 -1 0.1 -0.7 -1.4 12/19/2005 06:50:00 1.1 0.5 2.3 0.4 1 0.5 2.3 0.4 0.7 0.4 1.9 0.4 256 17 270 300 -1.4 0 -1.2 -1.4 12/19/2005 07:00:00 1.1 0.5 2.3 0.4 1 0.5 1.9 0.4 1.3 0.5 2.3 0.4 262 39 230 300 -1.2 0 -1 -1.2 12/19/2005 07:10:00 0.5 0.3 1.9 0.4 0.5 0.3 1.9 0.4 0.5 0.3 1.5 0.4 62 69 80 300 -1 0 -0.7 -1.4 12/19/2005 07:20:00 1.4 0.6 3 0.4 1.3 0.7 2.6 0.4 0.9 0.6 2.6 0.4 98 13 100 300 -1.3 0 -1.2 -1.4 12/19/2005 07:30:00 2.6 0.5 4.2 1.5 2.6 0.5 4.2 1.5 1.9 0.5 3.4 0.7 84 14 76 300 -1.3 0 -1.2 -1.4 12/19/2005 07:40:00 2.2 0.6 3.8 1.1 2.2 0.7 3.8 1.1 1.5 0.6 2.6 0.7 83 11 72 300 -1.2 0 -1 -1.4 12/19/2005 07:50:00 2.8 0.6 4.2 1.5 2.9 0.6 3.8 1.5 2.1 0.5 3.4 0.7 70 9 51 300 -1 0 -0.7 -1.2 12/19/2005 08:00:00 2.6 0.6 4.2 1.5 2.6 0.6 4.2 1.5 2 0.5 3 1.1 70 11 49 300 -1 0.1 -0.7 -1.2 12/19/2005 08:10:00 2.1 0.5 3.8 1.1 2.1 0.5 3.8 0.7 1.4 0.3 2.3 0.4 68 12 49 300 -0.8 0.1 -0.5 -1 12/19/2005 08:20:00 2.2 0.8 3.8 0.7 2.2 0.7 3.8 0.7 1.7 0.5 3 0.7 65 12 63 300 -1.1 0 -1 -1.2 12/19/2005 08:30:00 3.6 0.6 4.9 1.9 3.5 0.7 4.9 1.5 2.3 0.6 4.2 1.1 47 9 72 300 -0.8 0.1 -0.5 -1.2 12/19/2005 08:40:00 3 0.8 5.7 1.1 2.9 0.8 5.7 1.1 1.8 0.6 3.8 0.4 54 15 51 300 -0.6 0.2 -0.1 -0.7 12/19/2005 08:50:00 2.7 0.9 4.6 0.4 2.7 1 4.9 0.4 2 0.7 4.2 0.4 69 22 42 300 -0.9 0.1 -0.5 -1.4 12/19/2005 09:00:00 2.2 0.5 3 0.7 2.2 0.5 3 0.4 2.5 0.4 3.4 1.5 164 23 171 300 -1.9 0.2 -1.4 -2.1 12/19/2005 09:10:00 1.1 0.5 2.3 0.4 1.2 0.7 2.6 0.4 1.3 0.6 2.3 0.4 178 24 189 300 -2.2 0 -2.1 -2.4 12/19/2005 09:20:00 1.2 0.5 2.3 0.4 1.2 0.5 2.3 0.4 0.4 0.1 0.7 0.4 89 16 79 300 -2.1 0 -1.9 -2.1 12/19/2005 09:30:00 0.8 0.4 2.3 0.4 0.7 0.4 1.9 0.4 0.4 0.1 0.7 0.4 96 17 91 300 -2.1 0 -1.9 -2.1 12/19/2005 09:40:00 1.2 0.6 2.6 0.4 1.2 0.7 2.6 0.4 1.3 0.7 2.3 0.4 156 51 218 300 -1.7 0.1 -1.4 -2.1 12/19/2005 09:50:00 1.1 0.6 2.6 0.4 1 0.7 3 0.4 1.3 0.6 2.6 0.4 219 17 194 300 -1.2 0.2 -0.7 -1.4 12/19/2005 10:00:00 1 0.6 1.9 0.4 0.9 0.5 1.9 0.4 1.3 0.5 2.3 0.4 274 35 237 300 -1.2 0 -1 -1.4 12/19/2005 10:10:00 0.4 0.2 1.5 0.4 0.4 0.1 1.1 0.4 0.4 0.1 0.7 0.4 344 33 45 300 -1.6 0 -1.4 -1.7 12/19/2005 10:20:00 1.1 0.4 1.9 0.4 1.1 0.4 1.9 0.4 0.6 0.2 1.1 0.4 53 8 58 300 -1.6 0.2 -1.2 -1.9 12/19/2005 10:30:00 0.8 0.4 1.5 0.4 0.7 0.4 1.5 0.4 0.6 0.3 1.1 0.4 101 14 73 300 -1.4 0 -1.2 -1.4 12/19/2005 10:40:00 0.4 0.1 1.1 0.4 0.4 0.1 1.1 0.4 0.4 0 0.4 0.4 130 28 144 300 -1.5 0 -1.2 -1.4 12/19/2005 10:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 64 0 300 300 -1.5 0 -1.2 -1.4 12/19/2005 11:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.5 0.3 1.1 0.4 64 0 300 300 -1.7 0 -1.4 -1.9 12/19/2005 11:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0.1 0.7 0.4 64 0 300 300 -1.8 0 -1.7 -1.9 12/19/2005 11:20:00 0.8 0.4 1.5 0.4 0.8 0.4 1.9 0.4 0.5 0.2 1.1 0.4 64 0 64 300 -1.6 0 -1.4 -1.7 12/19/2005 11:30:00 1.4 0.3 2.3 1.1 1.5 0.3 2.3 0.7 0.6 0.2 1.1 0.4 58 2 57 300 -1.6 0 -1.4 -1.4 12/19/2005 11:40:00 1 0.5 2.3 0.4 0.9 0.6 2.6 0.4 0.5 0.2 1.1 0.4 80 22 57 300 -1.6 0 -1.4 -1.7 12/19/2005 11:50:00 0.4 0.1 0.7 0.4 0.4 0 0.4 0.4 0.4 0.1 1.1 0.4 106 0 106 300 -1.7 0 -1.4 -1.9 12/19/2005 12:00:00 0.5 0.3 1.5 0.4 0.4 0.1 1.1 0.4 0.4 0 0.4 0.4 90 27 42 300 -1.1 0.1 -1 -1.4 12/19/2005 12:10:00 2.3 1 4.2 0.4 1.9 0.9 3.4 0.4 0.8 0.4 2.3 0.4 31 7 32 300 -1 0 -0.7 -1.2 12/19/2005 12:20:00 2.6 0.5 3.8 1.5 2.3 0.6 3.4 0.7 0.8 0.6 2.3 0.4 37 6 37 300 -0.5 0.3 0.2 -0.7 12/19/2005 12:30:00 3.1 0.5 4.6 1.9 3 0.6 4.6 1.9 1.6 0.6 2.6 0.4 48 7 45 300 0.5 0.1 0.7 0.2 12/19/2005 12:40:00 1.1 0.7 3.4 0.4 1 0.7 3 0.4 1.3 0.5 2.6 0.4 110 41 43 300 0.1 0 0.4 -0.1 12/19/2005 12:50:00 0.5 0.3 1.5 0.4 0.5 0.3 1.9 0.4 1 0.3 1.5 0.4 94 39 77 300 0.2 0 0.4 0.2 12/19/2005 13:00:00 0.6 0.3 1.1 0.4 0.5 0.2 1.1 0.4 0.7 0.4 1.5 0.4 176 4 182 300 0.6 0.1 0.9 0.2 12/19/2005 13:10:00 1 0.4 1.9 0.4 1 0.4 1.5 0.4 0.9 0.3 1.5 0.4 187 13 183 300 1.1 0 1.4 0.9 12/19/2005 13:20:00 1 0.5 2.3 0.4 1.1 0.4 1.9 0.4 1.4 0.3 1.9 0.7 206 5 215 300 1.7 0.2 2.1 1.4 12/19/2005 13:30:00 1.2 0.4 2.3 0.4 1.1 0.4 2.3 0.4 0.9 0.4 1.9 0.4 220 0 219 300 2 0 2.3 1.8 12/19/2005 13:40:00 0.4 0.2 1.5 0.4 0.4 0.2 1.5 0.4 0.4 0.1 1.1 0.4 218 0 220 300 1.7 0 2.1 1.6 12/19/2005 13:50:00 0.4 0.1 1.1 0.4 0.4 0.1 1.1 0.4 0.4 0.2 1.1 0.4 283 72 6 300 1.5 0 1.8 1.4 12/19/2005 14:00:00 0.4 0.1 1.1 0.4 0.4 0.1 1.1 0.4 0.5 0.2 1.1 0.4 7 1 6 300 1.1 0.1 1.6 0.7 12/19/2005 14:10:00 0.4 0 0.7 0.4 0.4 0 0.4 0.4 0.5 0.2 1.1 0.4 7 0 7 300 0.6 0 0.7 0.4 12/19/2005 14:20:00 0.8 0.5 1.9 0.4 0.8 0.5 1.9 0.4 0.8 0.4 1.5 0.4 35 21 51 300 0.4 0.1 0.7 0.2 12/19/2005 14:30:00 2.4 0.5 3.4 1.5 2.4 0.5 3.4 1.5 1.9 0.3 2.6 1.1 47 3 43 300 -0.1 0.1 0.2 -0.3 12/19/2005 14:40:00 2 1 3.4 0.4 2 1 3.4 0.4 1.4 0.8 3 0.4 60 15 51 300 -0.3 0 -0.1 -0.5 12/19/2005 14:50:00 1.5 0.6 3.4 0.4 1.5 0.7 3.4 0.4 0.9 0.6 2.6 0.4 57 13 49 300 -0.4 0 -0.1 -0.5 12/19/2005 15:00:00 2.7 0.4 3.4 1.9 2.8 0.4 3.4 1.9 2.1 0.4 3 0.7 51 5 52 300 -0.5 0 -0.5 -0.7 12/19/2005 15:10:00 3.4 0.3 3.8 2.6 3.4 0.3 3.8 2.6 2.6 0.3 3.4 1.5 55 2 57 300 -1 0.2 -0.5 -1.4 12/19/2005 15:20:00 3.5 0.2 4.2 3 3.5 0.2 4.2 3 2.2 0.5 3 0.7 55 6 54 300 -1.6 0 -1.2 -1.7 12/19/2005 15:30:00 3.3 0.4 4.2 2.3 3.3 0.4 4.2 2.3 2.6 0.5 3.8 1.1 58 5 63 300 -1.2 0.1 -1 -1.4 12/19/2005 15:40:00 4 0.3 4.9 3.4 4 0.3 4.6 3 3.1 0.4 4.2 1.9 52 4 51 300 -0.9 0 -0.7 -1.2 12/19/2005 15:50:00 4.9 0.4 6.1 3.8 4.8 0.4 5.7 3.8 3.5 0.5 4.6 1.9 47 2 45 300 -1.7 0.2 -1.2 -2.1 12/19/2005 16:00:00 4.3 0.4 5.3 3 4.3 0.4 5.3 3 2.9 0.5 4.2 1.1 50 5 43 300 -1.7 0.1 -1.4 -2.1 12/19/2005 16:10:00 3.3 0.5 4.6 1.9 3.3 0.5 4.6 1.9 2.1 0.6 3.8 0.7 50 9 53 300 -0.8 0.3 -0.3 -1.4 12/19/2005 16:20:00 3.7 0.6 5.3 2.3 3.4 0.7 4.9 1.9 1.9 0.6 3.8 0.4 41 10 38 300 -0.2 0 -0.1 -0.5 12/19/2005 16:30:00 4.3 0.5 5.3 3 4.2 0.5 5.7 2.6 2.7 0.6 4.2 1.1 46 5 46 300 -0.1 0 0.2 -0.1 12/19/2005 16:40:00 4.4 0.5 5.7 2.6 4.3 0.6 5.7 1.9 2.6 0.6 4.2 1.1 44 7 49 300 0.3 0.2 0.9 0.2 12/19/2005 16:50:00 3.8 0.5 5.7 2.6 3.5 0.5 4.9 1.9 2.4 0.5 3.8 1.1 39 7 23 300 0.8 0 0.9 0.7 12/19/2005 17:00:00 4.3 0.7 6.1 2.3 4 0.8 5.7 2.3 2.7 0.6 4.2 1.1 39 7 35 300 1 0 1.4 0.7 12/19/2005 17:10:00 4 0.6 5.7 2.6 3.5 0.6 5.7 1.9 2.4 0.6 4.2 0.7 32 10 50 300 1.2 0.1 1.6 0.9 12/19/2005 17:20:00 4.4 0.8 6.5 1.9 3.8 0.8 5.7 1.1 2.8 0.6 4.9 1.1 29 9 13 300 2.1 0.3 2.6 1.6 12/19/2005 17:30:00 1.4 0.8 4.6 0.4 1.1 0.7 3.8 0.4 0.9 0.5 2.6 0.4 58 29 14 300 0.5 1.1 2.6 -0.7 12/19/2005 17:40:00 1.8 0.9 3.4 0.4 1.8 1.1 3.8 0.4 1.9 0.9 3.4 0.4 149 72 207 300 -1.6 0.4 -0.7 -2.1 12/19/2005 17:50:00 2.6 0.5 3.8 1.9 2.9 0.4 3.8 2.3 2.4 0.4 3.4 1.5 216 6 223 300 -2.4 0 -2.1 -2.6 12/19/2005 18:00:00 3.2 0.4 4.2 2.3 3 0.4 4.2 1.9 2.4 0.5 3.4 1.1 236 5 237 300 -2.5 0.1 -2.1 -2.6 12/19/2005 18:10:00 3 0.5 4.2 1.9 2.8 0.5 4.2 1.5 2.1 0.5 3.4 0.7 241 5 241 300 -2.3 0 -2.1 -2.6 12/19/2005 18:20:00 3.4 0.4 4.2 2.3 3.2 0.4 4.2 2.3 2.6 0.4 3.4 1.5 245 4 238 300 -2.1 0 -2.1 -2.4 12/19/2005 18:30:00 2.7 0.5 3.8 0.7 2.5 0.5 3.4 0.4 2 0.6 3.4 0.4 259 18 241 300 -2.1 0 -1.9 -2.4 12/19/2005 18:40:00 2.4 0.4 3 1.1 2.1 0.5 3 0.7 1.8 0.4 2.6 0.7 248 6 259 300 -2 0.1 -1.9 -2.4 12/19/2005 18:50:00 2.4 0.5 3.4 1.1 2.1 0.5 3 1.1 1.7 0.5 2.6 0.7 243 4 240 300 -1.9 0.1 -1.7 -2.1 12/19/2005 19:00:00 2 0.7 3.8 0.7 1.7 0.8 3.4 0.4 1.2 0.8 3 0.4 238 5 229 300 -2 0.2 -1.4 -2.4 12/19/2005 19:10:00 2.6 0.5 3.8 1.5 2.5 0.5 3.4 1.1 1.6 0.5 3 0.4 241 6 232 300 -2.1 0 -1.4 -2.1 12/19/2005 19:20:00 2.2 0.7 3.4 0.7 2 0.7 3.4 0.4 1.6 0.5 2.6 0.4 233 8 238 300 -2.2 0 -2.1 -2.4 12/19/2005 19:30:00 1.3 0.3 1.9 0.7 1.3 0.3 1.9 0.7 1.2 0.3 1.9 0.7 211 5 219 300 -2.8 0.2 -2.1 -3 12/19/2005 19:40:00 2.5 0.6 3.4 1.1 2.4 0.5 3.4 1.5 1.8 0.3 2.6 1.1 222 13 227 300 -3.1 0 -2.8 -3.3 12/19/2005 19:50:00 1.8 0.3 2.6 1.1 1.5 0.3 2.3 0.4 1 0.3 1.9 0.4 249 5 240 300 -3.2 0 -3 -3.3 12/19/2005 20:00:00 2 0.4 3 1.1 1.8 0.4 3 0.7 1.2 0.4 2.3 0.4 269 6 271 300 -3.2 0 -3 -3.3 12/19/2005 20:10:00 1.2 0.6 2.6 0.4 0.9 0.6 2.3 0.4 1 0.4 2.3 0.4 282 9 277 300 -3.1 0 -3 -3.3 12/19/2005 20:20:00 0.7 0.2 1.1 0.4 0.4 0 0.4 0.4 0.9 0.3 1.5 0.4 259 11 275 300 -3.3 0.1 -3 -3.5 12/19/2005 20:30:00 0.6 0.3 1.5 0.4 0.4 0.2 1.5 0.4 0.5 0.3 1.1 0.4 235 22 208 300 -3.3 0 -3 -3.5 12/19/2005 20:40:00 1.6 0.5 2.3 0.4 1.3 0.5 2.3 0.4 0.8 0.4 1.9 0.4 223 4 219 300 -3.5 0 -3.3 -3.5 12/19/2005 20:50:00 2 0.5 3 1.1 1.7 0.5 2.6 0.7 1.2 0.5 2.3 0.4 240 6 241 300 -3.6 0 -3.5 -3.7 12/19/2005 21:00:00 1.6 0.3 2.6 1.1 1.2 0.3 2.6 0.4 1.1 0.3 1.5 0.4 256 6 246 300 -3.3 0.2 -2.8 -3.5 12/19/2005 21:10:00 0.9 0.5 1.9 0.4 0.6 0.4 1.9 0.4 0.7 0.4 1.9 0.4 251 2 254 300 -3.3 0 -3 -3.5 12/19/2005 21:20:00 0.6 0.3 1.5 0.4 0.4 0 0.4 0.4 0.5 0.3 1.5 0.4 233 20 225 300 -4.1 0.2 -3.5 -4.4 12/19/2005 21:30:00 1.2 0.5 1.9 0.4 0.8 0.5 1.5 0.4 0.8 0.3 1.5 0.4 230 8 225 300 -4.1 0 -3.9 -4.4 12/19/2005 21:40:00 0.7 0.4 1.5 0.4 0.4 0.1 1.1 0.4 0.5 0.3 1.5 0.4 268 53 240 300 -3.9 0.1 -3.7 -4.4 12/19/2005 21:50:00 0.7 0.4 1.5 0.4 0.4 0.2 1.1 0.4 0.9 0.4 1.9 0.4 18 22 35 300 -4.3 0 -3.9 -4.6 12/19/2005 22:00:00 1.7 0.3 2.6 1.1 1.6 0.3 2.3 0.7 1.4 0.4 2.3 0.4 48 9 45 300 -4.3 0 -4.4 -4.6 12/19/2005 22:10:00 2.3 0.3 3 1.5 2.3 0.3 3 1.5 1.7 0.5 2.6 0.7 46 4 43 300 -4.2 0.1 -3.9 -4.4 12/19/2005 22:20:00 2 0.3 2.6 1.5 2 0.3 2.6 1.1 1.1 0.4 1.9 0.4 47 3 44 300 -4.3 0.2 -3.9 -4.6 12/19/2005 22:30:00 2.4 0.2 3 1.9 2.4 0.2 3 1.9 1.5 0.3 2.3 0.7 53 5 51 300 -4.5 0 -4.4 -4.6 12/19/2005 22:40:00 2 0.3 2.6 1.1 1.9 0.3 2.6 1.1 1.1 0.3 1.9 0.4 61 11 53 300 -4.7 0.1 -4.4 -4.8 12/19/2005 22:50:00 1.5 0.4 2.3 0.7 1.4 0.6 2.6 0.4 0.7 0.4 1.5 0.4 75 0 76 300 -4.7 0.1 -4.4 -4.8 12/19/2005 23:00:00 1.7 0.4 3 1.1 1.6 0.5 3 0.7 1.1 0.4 2.3 0.4 63 9 47 300 -4.8 0 -4.6 -5 12/19/2005 23:10:00 2.8 0.3 3.4 2.3 2.8 0.4 3.4 2.3 2.2 0.3 3 1.1 50 5 56 300 -4.7 0.5 -3.7 -5 12/19/2005 23:20:00 3.4 0.2 3.8 2.6 3.4 0.2 3.8 2.6 2.6 0.3 3.4 1.9 51 2 49 300 -4.3 0.2 -3.7 -4.6 12/19/2005 23:30:00 3.3 0.2 3.8 3 3.4 0.2 3.8 3 2.4 0.2 3 1.9 54 2 55 300 -4.2 0.1 -3.9 -4.4 12/19/2005 23:40:00 3.7 0.2 4.2 3 3.7 0.2 4.2 3 2.6 0.2 3.4 1.5 56 2 57 300 -4 0.1 -3.7 -4.4 12/19/2005 23:50:00 2.8 0.6 4.2 1.5 2.8 0.6 4.2 1.9 1.7 0.6 3 0.4 56 3 57 300 -3.9 0.1 -3.5 -4.2 12/20/2005 00:00:00 2.4 0.3 3 1.9 2.4 0.3 3 1.9 1.7 0.2 2.3 1.1 55 4 62 300 -3.7 0.1 -3.5 -4.2 12/20/2005 00:10:00 2.7 0.2 3 2.3 2.7 0.2 3 1.9 1.8 0.2 2.3 1.1 64 2 62 300 -4 0.2 -3.5 -4.4 12/20/2005 00:20:00 3 0.4 3.8 2.3 3 0.4 3.8 2.3 2.1 0.3 2.6 1.5 72 4 76 300 -4.3 0 -4.2 -4.4 12/20/2005 00:30:00 2.5 0.6 4.2 1.9 2.5 0.6 4.2 1.9 1.9 0.3 2.6 1.5 73 5 80 300 -4.1 0.4 -3.3 -4.6 12/20/2005 00:40:00 2.5 0.5 3.4 1.5 2.5 0.5 3.4 1.9 1.6 0.2 1.9 1.1 70 3 70 300 -3.4 0 -3.3 -3.5 12/20/2005 00:50:00 3.6 0.4 4.2 2.6 3.6 0.4 4.2 1.9 2.2 0.4 3 1.1 49 9 55 300 -3.6 0.1 -3.3 -3.9 12/20/2005 01:00:00 3.1 0.2 3.8 2.6 3.1 0.2 3.8 2.6 1.9 0.3 2.6 1.1 47 6 38 300 -3.8 0 -3.7 -3.9 12/20/2005 01:10:00 2.4 0.4 3.4 1.5 2.4 0.4 3.4 1.5 1.6 0.4 2.6 1.1 51 7 64 300 -3.7 0.1 -3.5 -3.9 12/20/2005 01:20:00 2.4 0.3 3.4 1.5 2.4 0.3 3.4 1.5 1.4 0.4 2.3 0.4 43 3 43 300 -4.2 0.4 -3.5 -4.6 12/20/2005 01:30:00 2.9 0.3 3.4 2.3 2.8 0.3 3.4 2.3 1.4 0.3 2.3 0.7 33 6 44 300 -4.7 0.1 -4.4 -4.8 12/20/2005 01:40:00 3.1 0.3 3.8 2.3 3 0.3 3.8 1.9 1.9 0.3 2.6 1.1 38 3 42 300 -4.3 0 -3.9 -4.4 12/20/2005 01:50:00 2.5 0.6 3.4 1.1 2.4 0.5 3.4 1.1 1.4 0.5 2.3 0.4 37 5 34 300 -4.5 0.2 -4.4 -4.8 12/20/2005 02:00:00 1.4 0.5 2.6 0.4 1.4 0.5 2.6 0.4 0.8 0.6 2.3 0.4 47 4 53 300 -4.3 0 -4.2 -4.4 12/20/2005 02:10:00 2.1 0.7 3 0.4 2.1 0.7 3 0.4 1.4 0.6 2.3 0.4 76 9 72 300 -4.3 0 -3.9 -4.6 12/20/2005 02:20:00 1.6 0.4 2.3 0.7 1.6 0.5 2.3 0.7 0.5 0.2 1.1 0.4 70 17 63 300 -4.9 0.2 -4.6 -5.3 12/20/2005 02:30:00 2.9 0.4 3.8 2.3 2.9 0.4 3.8 2.3 1.9 0.5 2.6 0.7 49 3 48 300 -4.8 0.3 -4.4 -5.5 12/20/2005 02:40:00 2.7 0.4 3.4 1.9 2.6 0.4 3.4 1.5 1.6 0.5 2.6 0.4 32 7 46 300 -4.7 0 -4.4 -4.8 12/20/2005 02:50:00 2.1 0.3 3 1.1 2 0.4 3 1.1 1.3 0.4 1.9 0.4 14 7 0 300 -4.2 0.1 -3.9 -4.6 12/20/2005 03:00:00 0.8 0.6 2.3 0.4 0.8 0.6 2.3 0.4 0.7 0.4 1.5 0.4 14 11 2 300 -4 0.3 -3.5 -4.8 12/20/2005 03:10:00 0.4 0.2 1.1 0.4 0.4 0.1 1.1 0.4 0.7 0.3 1.5 0.4 326 51 21 300 -5.6 0.4 -4.8 -6.4 12/20/2005 03:20:00 1.1 0.4 2.3 0.4 1.2 0.5 2.3 0.4 1.8 0.4 2.6 0.7 205 12 205 300 -6.5 0 -6.4 -6.6 12/20/2005 03:30:00 1.8 0.3 2.3 0.7 1.6 0.3 2.3 0.7 1.4 0.5 2.3 0.4 232 5 229 300 -6.6 0 -6.6 -6.8 12/20/2005 03:40:00 2.6 0.7 3.8 1.5 2.4 0.7 3.4 1.1 1.9 0.6 3 0.7 240 6 237 300 -6.7 0 -6.6 -6.8 12/20/2005 03:50:00 2.2 0.5 3.4 1.1 2 0.5 3.4 0.7 1.3 0.6 3 0.4 249 5 241 300 -6.5 0 -6.1 -6.6 12/20/2005 04:00:00 2.2 0.5 3 1.1 2 0.5 3 1.1 1.1 0.5 2.3 0.4 245 7 244 300 -6.4 0 -6.1 -6.6 12/20/2005 04:10:00 2.6 0.3 3.4 1.9 2.4 0.3 3 1.5 1.9 0.3 2.6 1.1 237 6 236 300 -6 0 -5.9 -6.1 12/20/2005 04:20:00 2.1 0.4 3 1.1 2 0.4 2.6 0.7 1.4 0.2 1.9 0.7 252 6 253 300 -6 0.1 -5.7 -6.1 12/20/2005 04:30:00 2.4 0.4 3.4 1.5 2.2 0.4 3 1.5 1.5 0.3 2.3 0.7 255 10 258 300 -5.9 0 -5.7 -5.9 12/20/2005 04:40:00 2.5 0.3 3 1.9 2.3 0.3 3 1.9 1.3 0.4 2.3 0.4 253 6 256 300 -6 0 -5.9 -6.1 12/20/2005 04:50:00 2.6 0.2 3 1.9 2.4 0.2 3 1.9 1.3 0.4 2.3 0.4 253 4 251 300 -6.4 0.1 -6.1 -6.6 12/20/2005 05:00:00 2 0.4 2.6 0.7 1.7 0.5 2.6 0.4 0.7 0.4 1.5 0.4 256 2 260 300 -6.5 0 -6.6 -6.6 12/20/2005 05:10:00 2 0.4 3 0.7 1.8 0.4 2.6 0.7 0.8 0.5 1.9 0.4 264 6 267 300 -6.7 0 -6.6 -6.8 12/20/2005 05:20:00 1.4 0.5 2.6 0.7 1 0.6 2.6 0.4 0.6 0.4 1.9 0.4 262 7 271 300 -7 0 -6.6 -7.2 12/20/2005 05:30:00 1.2 0.5 2.3 0.4 0.9 0.5 1.9 0.4 0.4 0.1 0.7 0.4 271 12 271 300 -7.3 0 -7 -7.2 12/20/2005 05:40:00 1 0.4 1.9 0.4 0.6 0.4 1.5 0.4 0.5 0.2 1.5 0.4 233 6 229 300 -7.2 0 -7 -7.2 12/20/2005 05:50:00 0.4 0.2 1.5 0.4 0.4 0.1 1.1 0.4 0.4 0 0.4 0.4 228 0 229 300 -7.3 0 -7 -7.2 12/20/2005 06:00:00 0.6 0.3 1.5 0.4 0.4 0.2 1.1 0.4 0.4 0.1 0.7 0.4 228 0 229 300 -7.5 0.1 -7.2 -7.6 12/20/2005 06:10:00 0.9 0.4 1.9 0.4 0.7 0.3 1.5 0.4 0.4 0.1 0.7 0.4 257 28 275 300 -7.3 0 -7 -7.4 12/20/2005 06:20:00 0.6 0.3 1.5 0.4 0.4 0.2 1.1 0.4 0.7 0.4 1.9 0.4 304 35 269 300 -7.2 0 -7.2 -7.2 12/20/2005 06:30:00 0.8 0.3 1.5 0.4 0.5 0.2 1.1 0.4 0.7 0.3 1.5 0.4 313 16 297 300 -7.2 0 -7.2 -7.2 12/20/2005 06:40:00 1.6 0.4 2.3 0.4 1.4 0.4 2.3 0.4 1.1 0.3 1.5 0.4 293 2 295 300 -7.3 0 -7.2 -7.2 12/20/2005 06:50:00 1.3 0.4 2.3 0.4 1.1 0.4 1.9 0.4 0.4 0.2 1.1 0.4 268 15 280 300 -7.4 0.1 -7.2 -7.4 12/20/2005 07:00:00 0.6 0.3 1.1 0.4 0.4 0.1 1.1 0.4 0.4 0.1 0.7 0.4 229 22 251 300 -7.6 0 -7.4 -7.6 12/20/2005 07:10:00 0.8 0.4 1.5 0.4 0.6 0.3 1.5 0.4 0.4 0.1 0.7 0.4 272 12 271 300 -7.6 0 -7.4 -7.6 12/20/2005 07:20:00 0.5 0.2 1.1 0.4 0.4 0.1 0.7 0.4 0.7 0.4 1.5 0.4 255 30 218 300 -7.5 0.1 -7.2 -7.6 12/20/2005 07:30:00 0.4 0.1 1.1 0.4 0.4 0 0.4 0.4 0.5 0.3 1.5 0.4 218 0 218 300 -7.4 0 -7.2 -7.4 12/20/2005 07:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0.2 1.1 0.4 218 0 300 300 -7.4 0 -7.2 -7.4 12/20/2005 07:50:00 0.5 0.2 1.1 0.4 0.4 0.1 1.1 0.4 0.9 0.3 1.5 0.4 240 66 218 300 -7.5 0 -7.2 -7.6 12/20/2005 08:00:00 0.4 0.2 1.5 0.4 0.4 0.2 1.1 0.4 0.6 0.4 1.5 0.4 100 38 41 300 -7.6 0 -7.4 -7.6 12/20/2005 08:10:00 1.3 0.5 2.3 0.4 1.2 0.5 2.3 0.4 1.5 0.3 2.3 0.7 42 4 48 300 -7.6 0 -7.4 -7.6 12/20/2005 08:20:00 1.8 0.2 2.3 1.1 1.8 0.2 2.3 1.1 1.4 0.2 1.9 0.7 65 8 53 300 -7.7 0 -7.6 -7.9 12/20/2005 08:30:00 1.7 0.2 2.3 1.1 1.7 0.2 2.3 1.1 1.1 0.3 1.9 0.4 67 5 73 300 -7.7 0 -7.6 -7.9 12/20/2005 08:40:00 2 0.3 2.6 1.1 2 0.3 2.6 1.1 1.6 0.3 2.3 1.1 51 5 48 300 -7.9 0 -7.6 -8.1 12/20/2005 08:50:00 1.3 0.7 2.6 0.4 1.2 0.7 2.6 0.4 2.1 0.2 2.6 1.5 52 12 35 300 -7.1 0.3 -6.8 -7.9 12/20/2005 09:00:00 1.4 0.4 2.3 0.4 1.4 0.5 2.3 0.4 1.8 0.3 2.6 0.7 48 11 51 300 -6.9 0.1 -6.6 -7.2 12/20/2005 09:10:00 1.6 0.3 2.3 0.7 1.5 0.4 2.3 0.7 1.5 0.2 2.3 0.7 62 22 35 300 -7.4 0 -7.2 -7.6 12/20/2005 09:20:00 1 0.4 1.9 0.4 0.9 0.4 1.9 0.4 1.5 0.3 1.9 0.7 74 17 46 300 -7.5 0.1 -7.2 -7.6 12/20/2005 09:30:00 0.4 0.2 1.1 0.4 0.4 0.2 1.1 0.4 1.5 0.2 1.9 1.1 64 7 60 300 -7.4 0.1 -7 -7.6 12/20/2005 09:40:00 0.5 0.3 1.5 0.4 0.5 0.3 1.5 0.4 0.6 0.3 1.5 0.4 49 14 37 300 -7.5 0.3 -7 -8.1 12/20/2005 09:50:00 0.4 0 0.7 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 62 9 65 300 -7.9 0 -7.6 -8.1 12/20/2005 10:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0.1 0.7 0.4 65 0 300 300 -7.7 0.1 -7.6 -8.1 12/20/2005 10:10:00 0.4 0.1 1.1 0.4 0.4 0.1 1.1 0.4 0.5 0.4 1.9 0.4 320 94 189 300 -7.9 0.1 -7.6 -8.1 12/20/2005 10:20:00 0.5 0.2 1.1 0.4 0.4 0.2 1.1 0.4 0.7 0.5 1.9 0.4 210 11 191 300 -8.3 0 -8.1 -8.5 12/20/2005 10:30:00 0.4 0.2 1.1 0.4 0.4 0 0.4 0.4 0.5 0.2 1.1 0.4 240 24 272 300 -8.2 0 -8.1 -8.3 12/20/2005 10:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 1 0.3 1.5 0.4 292 7 300 300 -8.1 0.1 -7.9 -8.1 12/20/2005 10:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.5 0.2 1.1 0.4 58 58 300 300 -8 0 -7.9 -8.1 12/20/2005 11:00:00 0.6 0.3 1.1 0.4 0.4 0.1 1.1 0.4 0.8 0.4 1.5 0.4 262 27 231 300 -8.2 0 -8.1 -8.3 12/20/2005 11:10:00 0.6 0.3 1.1 0.4 0.4 0.1 1.1 0.4 0.6 0.2 1.1 0.4 225 33 189 300 -8.3 0 -8.3 -8.5 12/20/2005 11:20:00 0.4 0.1 1.1 0.4 0.4 0.1 0.7 0.4 0.4 0.1 0.7 0.4 190 0 190 300 -8.3 0 -8.1 -8.3 12/20/2005 11:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 190 0 300 300 -8.2 0 -8.1 -8.3 12/20/2005 11:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 190 0 300 300 -8.1 0 -7.9 -8.1 12/20/2005 11:50:00 0.4 0 0.7 0.4 0.4 0 0.4 0.4 0.6 0.3 1.1 0.4 139 72 36 300 -8.1 0 -7.9 -8.1 12/20/2005 12:00:00 1.3 0.5 1.9 0.4 1.2 0.5 1.9 0.4 1.3 0.4 2.3 0.4 39 4 37 300 -8 0 -7.9 -8.1 12/20/2005 12:10:00 1.8 0.3 2.6 1.5 1.8 0.3 2.3 1.5 1.7 0.2 2.3 1.1 62 6 53 300 -8 0 -7.9 -8.1 12/20/2005 12:20:00 1.7 0.2 2.3 1.1 1.7 0.2 2.3 1.1 1.8 0.2 2.3 1.1 70 4 70 300 -7.5 0.3 -6.8 -8.1 12/20/2005 12:30:00 1.8 0.2 2.3 1.5 1.7 0.2 2.3 1.5 1.9 0.3 2.6 1.1 58 6 53 300 -6.5 0.2 -6.1 -6.8 12/20/2005 12:40:00 1.6 0.2 2.3 1.1 1.4 0.3 1.9 0.7 1.5 0.2 1.9 1.1 78 6 82 300 -6 0 -5.9 -6.1 12/20/2005 12:50:00 2 0.2 2.6 1.5 1.9 0.2 2.3 1.5 2 0.3 2.6 1.1 71 12 60 300 -6 0 -5.9 -6.1 12/20/2005 13:00:00 1.8 0.4 2.6 0.7 1.7 0.3 2.6 0.7 1.6 0.3 2.3 0.7 50 13 22 300 -6 0 -5.9 -6.1 12/20/2005 13:10:00 2 0.2 2.6 1.5 1.8 0.2 2.3 1.1 1.3 0.3 2.3 0.7 34 6 25 300 -5.5 0.2 -5 -5.9 12/20/2005 13:20:00 1.5 0.3 2.3 0.7 1.3 0.4 1.9 0.4 0.8 0.4 1.5 0.4 55 9 38 300 -4.6 0.4 -3.9 -5.3 12/20/2005 13:30:00 0.5 0.2 1.1 0.4 0.4 0.1 1.1 0.4 0.5 0.2 1.1 0.4 115 27 85 300 -4.7 0.2 -4.2 -4.8 12/20/2005 13:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 112 47 300 300 -4.6 0 -4.4 -4.6 12/20/2005 13:50:00 0.8 0.3 1.5 0.4 0.4 0 0.4 0.4 0.9 0.4 1.5 0.4 58 0 57 300 -4.8 0 -4.6 -4.8 12/20/2005 14:00:00 1.9 0.4 2.6 1.1 0.4 0 0.4 0.4 1.7 0.3 2.6 1.1 58 0 58 300 -5.1 0.2 -4.8 -5.7 12/20/2005 14:10:00 1.6 0.4 2.6 0.7 0.4 0 0.4 0.4 1.4 0.4 2.3 0.4 58 0 57 300 -5.6 0 -5.5 -5.7 12/20/2005 14:20:00 1.4 0.4 2.6 0.7 0.6 0.6 2.6 0.4 1.1 0.4 2.3 0.4 58 0 57 300 -5.6 0 -5.5 -5.7 12/20/2005 14:30:00 1.8 0.4 2.6 1.1 1.6 0.4 2.6 0.7 1.1 0.4 2.3 0.4 58 0 58 300 -5.7 0 -5.5 -5.7 12/20/2005 14:40:00 2.4 0.3 3 1.5 2.1 0.4 3 1.1 1.4 0.3 2.6 0.7 58 0 58 300 -5.4 0.2 -4.8 -5.7 12/20/2005 14:50:00 2.4 0.3 3.4 1.5 2.3 0.3 3 1.5 1.5 0.3 2.3 0.4 58 0 57 300 -5.1 0.2 -4.8 -5.5 12/20/2005 15:00:00 2.8 0.7 3.8 1.5 2.8 0.7 3.8 1.5 1.8 0.4 3 1.1 58 0 57 300 -5.4 0 -5.3 -5.5 12/20/2005 15:10:00 1.1 0.9 3.8 0.4 1.1 1 3.8 0.4 0.9 0.5 2.6 0.4 58 0 57 300 -5.5 0.2 -5 -5.9 12/20/2005 15:20:00 0.7 0.5 1.9 0.4 0.7 0.5 2.3 0.4 1.3 0.7 2.6 0.4 58 0 58 300 -6.4 0.3 -5.9 -6.8 12/20/2005 15:30:00 1.1 0.4 1.9 0.4 1 0.5 2.3 0.4 1.3 0.4 2.3 0.4 58 0 58 300 -7 0 -6.8 -7 12/20/2005 15:40:00 0.7 0.3 1.5 0.4 0.4 0.2 1.1 0.4 1.1 0.4 1.5 0.4 58 0 57 300 -7.1 0 -7 -7.2 12/20/2005 15:50:00 1.1 0.5 1.9 0.4 1 0.5 1.9 0.4 1.2 0.5 1.9 0.4 58 0 58 300 -7.3 0.2 -7 -7.6 12/20/2005 16:00:00 0.8 0.5 1.5 0.4 0.6 0.4 1.5 0.4 0.8 0.3 1.5 0.4 58 0 57 300 -7.5 0 -7.4 -7.6 12/20/2005 16:10:00 1 0.4 1.9 0.4 0.6 0.4 1.9 0.4 0.7 0.4 1.5 0.4 58 0 58 300 -7.6 0 -7.6 -7.6 12/20/2005 16:20:00 0.8 0.3 1.5 0.4 0.4 0.1 1.1 0.4 0.5 0.2 1.1 0.4 58 0 57 300 -7.7 0 -7.6 -7.9 12/20/2005 16:30:00 0.5 0.3 1.1 0.4 0.4 0.1 0.7 0.4 0.5 0.2 1.1 0.4 58 0 58 300 -8 0.1 -7.6 -8.1 12/20/2005 16:40:00 0.6 0.3 1.5 0.4 0.4 0.2 1.1 0.4 0.5 0.3 1.1 0.4 58 0 57 300 -8.1 0 -8.1 -8.1 12/20/2005 16:50:00 0.5 0.2 1.5 0.4 0.4 0.1 1.1 0.4 0.6 0.3 1.5 0.4 58 0 57 300 -7.9 0 -7.9 -8.1 12/20/2005 17:00:00 1 0.5 2.3 0.4 0.9 0.5 1.9 0.4 1.2 0.4 2.3 0.4 58 0 58 300 -8.1 0 -7.9 -8.3 12/20/2005 17:10:00 1.1 0.4 2.3 0.4 1 0.4 2.3 0.4 1 0.4 1.9 0.4 58 0 57 300 -8.3 0 -8.1 -8.5 12/20/2005 17:20:00 0.5 0.2 1.1 0.4 0.4 0.1 1.1 0.4 0.4 0.2 1.1 0.4 58 0 58 300 -8.5 0 -8.3 -8.5 12/20/2005 17:30:00 0.7 0.3 1.5 0.4 0.4 0.2 1.1 0.4 0.4 0.2 1.1 0.4 58 0 57 300 -8.4 0 -8.1 -8.5 12/20/2005 17:40:00 0.9 0.4 1.5 0.4 0.7 0.4 1.5 0.4 0.8 0.4 1.5 0.4 58 0 57 300 -8.3 0 -8.1 -8.5 12/20/2005 17:50:00 0.8 0.3 1.5 0.4 0.5 0.3 1.5 0.4 0.5 0.2 1.1 0.4 58 0 58 300 -8.4 0.1 -8.3 -8.7 12/20/2005 18:00:00 0.5 0.2 1.5 0.4 0.4 0.1 1.1 0.4 1.4 0.4 2.3 0.4 58 0 57 300 -8.5 0 -8.5 -8.7 12/20/2005 18:10:00 0.9 0.5 2.6 0.4 0.8 0.5 2.6 0.4 0.8 0.5 1.9 0.4 58 0 57 300 -8.7 0 -8.5 -8.9 12/20/2005 18:20:00 0.4 0.2 1.1 0.4 0.4 0.1 1.1 0.4 0.7 0.3 1.1 0.4 58 0 57 300 -8.9 0 -8.7 -8.9 12/20/2005 18:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.7 0.4 58 0 300 300 -9 0 -8.9 -9.1 12/20/2005 18:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0.1 0.7 0.4 58 0 300 300 -8.9 0 -8.7 -8.9 12/20/2005 18:50:00 0.7 0.5 1.9 0.4 0.6 0.5 1.9 0.4 0.4 0.1 1.1 0.4 58 0 57 300 -9.1 0 -8.9 -9.1 12/20/2005 19:00:00 0.7 0.6 2.3 0.4 0.7 0.6 2.3 0.4 0.7 0.5 2.3 0.4 58 0 57 300 -9.3 0 -8.9 -9.3 12/20/2005 19:10:00 0.5 0.2 1.1 0.4 0.5 0.2 1.1 0.4 0.4 0 0.4 0.4 58 0 57 300 -9.3 0 -9.3 -9.3 12/20/2005 19:20:00 0.7 0.3 1.9 0.4 0.7 0.3 1.9 0.4 0.6 0.3 1.1 0.4 58 0 58 300 -9.2 0 -9.1 -9.3 12/20/2005 19:30:00 0.5 0.3 1.5 0.4 0.4 0.2 1.5 0.4 1.3 0.3 1.9 0.4 58 0 57 300 -9.1 0.1 -8.9 -9.3 12/20/2005 19:40:00 0.6 0.4 1.9 0.4 0.6 0.4 1.9 0.4 1.4 0.2 1.9 0.7 58 0 58 300 -8.9 0 -8.7 -9.1 12/20/2005 19:50:00 1.7 0.3 2.3 0.7 1.5 0.4 2.3 0.4 1 0.4 1.9 0.4 58 0 58 300 -9.2 0 -8.9 -9.3 12/20/2005 20:00:00 1.4 0.3 1.9 0.4 1.2 0.3 1.9 0.4 0.9 0.3 1.5 0.4 58 0 58 300 -9.3 0 -9.3 -9.3 12/20/2005 20:10:00 1.2 0.3 1.9 0.7 0.9 0.4 1.5 0.4 0.6 0.2 1.1 0.4 58 0 57 300 -9.3 0 -9.3 -9.3 12/20/2005 20:20:00 1.1 0.3 1.9 0.4 0.7 0.4 1.5 0.4 0.4 0 0.7 0.4 58 0 58 300 -9.3 0 -9.3 -9.3 12/20/2005 20:30:00 0.7 0.3 1.5 0.4 0.4 0.2 1.1 0.4 0.4 0 0.4 0.4 58 0 57 300 -9.3 0 -9.3 -9.5 12/20/2005 20:40:00 0.7 0.4 1.5 0.4 0.6 0.3 1.5 0.4 0.4 0.1 1.1 0.4 58 0 57 300 -9.5 0 -9.3 -9.7 12/20/2005 20:50:00 0.6 0.3 1.5 0.4 0.4 0.2 1.1 0.4 0.4 0 0.4 0.4 58 0 58 300 -9.4 0 -9.3 -9.5 12/20/2005 21:00:00 1.1 0.4 1.9 0.4 0.8 0.4 1.9 0.4 0.4 0.2 1.1 0.4 58 0 57 300 -9.3 0 -9.3 -9.3 12/20/2005 21:10:00 1.8 0.3 2.6 1.1 1.6 0.3 2.3 1.1 1 0.3 1.9 0.4 58 0 57 300 -9.4 0 -9.3 -9.5 12/20/2005 21:20:00 2.1 0.2 2.6 1.5 2 0.2 2.6 1.5 1.6 0.3 2.3 0.7 58 0 58 300 -9.2 0 -8.9 -9.3 12/20/2005 21:30:00 2.2 0.3 3 1.5 2 0.3 2.6 1.5 1.6 0.4 2.3 0.4 58 0 57 300 -8.9 0.2 -8.3 -9.3 12/20/2005 21:40:00 1.9 0.4 3 0.7 1.9 0.4 2.6 1.1 1.2 0.4 2.3 0.4 58 0 58 300 -8.7 0 -8.3 -8.9 12/20/2005 21:50:00 1.5 0.4 2.3 0.7 1.3 0.4 1.9 0.4 0.5 0.2 1.1 0.4 58 0 57 300 -8.7 0 -8.5 -8.9 12/20/2005 22:00:00 1.3 0.5 2.6 0.4 1.1 0.5 2.3 0.4 0.4 0.1 1.1 0.4 58 0 57 300 -8.6 0 -8.5 -8.7 12/20/2005 22:10:00 1.5 0.6 2.6 0.4 1.2 0.6 2.6 0.4 0.6 0.4 1.9 0.4 58 0 57 300 -8.6 0 -8.5 -8.7 12/20/2005 22:20:00 1.8 0.6 3 0.4 1.7 0.7 2.6 0.4 1.3 0.6 2.3 0.4 58 0 58 300 -8.4 0 -8.3 -8.5 12/20/2005 22:30:00 1.9 0.3 2.6 1.1 1.7 0.3 2.3 1.1 1.5 0.4 2.3 0.7 58 0 57 300 -8.3 0 -8.1 -8.5 12/20/2005 22:40:00 1.7 0.2 2.3 1.1 1.4 0.2 2.3 1.1 1.2 0.3 1.9 0.7 58 0 57 300 -8.1 0 -7.9 -8.3 12/20/2005 22:50:00 2 0.3 2.6 1.5 1.8 0.3 2.6 1.1 1.5 0.3 2.3 0.4 58 0 57 300 -7.9 0 -7.6 -8.1 12/20/2005 23:00:00 1.9 0.4 2.6 0.7 1.7 0.4 2.3 0.4 1.7 0.4 2.6 0.7 58 0 58 300 -7.3 0.2 -7 -8.1 12/20/2005 23:10:00 0.6 0.3 1.5 0.4 0.5 0.2 1.5 0.4 0.7 0.4 1.9 0.4 58 0 57 300 -6.9 0.2 -6.6 -7 12/20/2005 23:20:00 1.5 0.6 2.6 0.4 1.3 0.6 2.6 0.4 1.2 0.4 1.9 0.4 58 0 57 300 -6.6 0.1 -6.4 -6.8 12/20/2005 23:30:00 1.9 0.3 2.3 1.1 1.6 0.3 2.3 0.7 1.1 0.4 2.3 0.4 58 0 57 300 -7 0.2 -6.8 -7.4 12/20/2005 23:40:00 1.7 0.2 2.3 1.1 1.5 0.2 1.9 0.7 0.7 0.3 1.5 0.4 58 0 57 300 -7.7 0.1 -7.4 -8.1 12/20/2005 23:50:00 1.7 0.5 2.3 0.4 1.6 0.5 2.3 0.4 0.7 0.4 1.5 0.4 58 0 57 300 -8 0 -7.9 -8.1 12/21/2005 00:00:00 1.1 0.6 2.3 0.4 0.9 0.5 1.9 0.4 0.8 0.5 2.6 0.4 58 0 57 300 -7.9 0 -7.6 -8.1 12/21/2005 00:10:00 0.5 0.2 1.1 0.4 0.4 0.1 1.1 0.4 0.5 0.2 1.1 0.4 58 0 57 300 -7.7 0 -7.6 -7.9 12/21/2005 00:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.7 0.4 58 0 300 300 -7.5 0 -7.4 -7.6 12/21/2005 00:30:00 0.4 0 0.7 0.4 0.4 0 0.4 0.4 0.4 0.1 1.1 0.4 58 0 57 300 -7.5 0 -7.2 -7.4 12/21/2005 00:40:00 0.4 0 0.7 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 58 0 57 300 -7.4 0 -7.2 -7.4 12/21/2005 00:50:00 0.7 0.3 1.5 0.4 0.5 0.3 1.5 0.4 0.4 0.1 0.7 0.4 58 0 57 300 -7.2 0 -7.2 -7.4 12/21/2005 01:00:00 0.8 0.3 1.5 0.4 0.5 0.2 1.1 0.4 0.4 0 0.4 0.4 58 0 57 300 -7.2 0 -7.2 -7.2 12/21/2005 01:10:00 1.3 0.3 1.9 0.4 1.1 0.4 1.9 0.4 0.5 0.2 1.1 0.4 58 0 57 300 -7.2 0 -7 -7.2 12/21/2005 01:20:00 0.8 0.4 1.9 0.4 0.5 0.3 1.5 0.4 0.4 0.2 1.1 0.4 58 0 57 300 -7.1 0 -7 -7.2 12/21/2005 01:30:00 0.5 0.2 1.1 0.4 0.4 0.1 1.1 0.4 0.6 0.3 1.1 0.4 58 0 57 300 -7.2 0 -7 -7.2 12/21/2005 01:40:00 0.7 0.3 1.5 0.4 0.4 0.2 1.1 0.4 0.4 0 0.4 0.4 58 0 57 300 -7.1 0 -7 -7.2 12/21/2005 01:50:00 0.6 0.2 1.1 0.4 0.4 0.1 0.7 0.4 0.4 0 0.4 0.4 58 0 57 300 -7 0 -6.8 -7 12/21/2005 02:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 58 0 300 300 -6.7 0 -6.6 -6.8 12/21/2005 02:10:00 0.5 0.3 1.5 0.4 0.5 0.2 1.1 0.4 0.6 0.3 1.5 0.4 58 0 57 300 -6.7 0 -6.6 -6.8 12/21/2005 02:20:00 0.6 0.3 1.5 0.4 0.5 0.2 1.1 0.4 0.6 0.3 1.5 0.4 58 0 57 300 -6.6 0 -6.6 -6.8 12/21/2005 02:30:00 0.5 0.2 1.1 0.4 0.4 0.2 1.1 0.4 0.4 0.2 0.7 0.4 58 0 57 300 -6.5 0 -6.6 -6.6 12/21/2005 02:40:00 0.5 0.2 1.1 0.4 0.5 0.2 1.1 0.4 0.4 0.1 1.1 0.4 58 0 57 300 -6.5 0 -6.4 -6.6 12/21/2005 02:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 58 0 300 300 -6.5 0 -6.4 -6.6 12/21/2005 03:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 58 0 300 300 -6.3 0 -6.1 -6.6 12/21/2005 03:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 58 0 300 300 -6.2 0 -6.1 -6.1 12/21/2005 03:20:00 0.4 0.2 1.5 0.4 0.4 0.2 1.5 0.4 0.4 0.2 1.1 0.4 58 0 57 300 -6.1 0 -5.9 -6.1 12/21/2005 03:30:00 0.5 0.3 1.1 0.4 0.5 0.2 1.5 0.4 0.4 0.2 1.1 0.4 58 0 57 300 -6 0 -5.9 -6.1 12/21/2005 03:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 58 0 300 300 -6 0 -5.9 -6.1 12/21/2005 03:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 58 0 300 300 -6 0 -5.9 -6.1 12/21/2005 04:00:00 0.4 0.1 0.7 0.4 0.4 0.1 0.7 0.4 0.4 0.1 0.7 0.4 58 0 57 300 -6 0 -5.7 -6.1 12/21/2005 04:10:00 0.4 0 0.7 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 58 0 57 300 -5.9 0 -5.7 -5.9 12/21/2005 04:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 58 0 300 300 -5.8 0 -5.7 -5.9 12/21/2005 04:30:00 0.4 0 0.4 0.4 0.4 0 0.7 0.4 0.4 0 0.4 0.4 58 0 300 300 -5.7 0 -5.7 -5.7 12/21/2005 04:40:00 0.4 0.1 0.7 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 58 0 57 300 -5.6 0 -5.5 -5.7 12/21/2005 04:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.7 0.4 58 0 300 300 -5.5 0 -5.5 -5.7 12/21/2005 05:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 58 0 300 300 -5.4 0 -5.3 -5.5 12/21/2005 05:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 58 0 300 300 -5.4 0 -5.3 -5.5 12/21/2005 05:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 58 0 300 300 -5.3 0 -5.3 -5.5 12/21/2005 05:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 58 0 300 300 -5.3 0 -5 -5.3 12/21/2005 05:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 58 0 300 300 -5.1 0 -5 -5.3 12/21/2005 05:50:00 0.4 0.1 1.1 0.4 0.4 0.1 1.1 0.4 0.4 0.1 1.1 0.4 58 0 57 300 -5 0 -4.8 -5 12/21/2005 06:00:00 0.9 0.3 1.5 0.4 0.7 0.3 1.5 0.4 0.6 0.3 1.5 0.4 58 0 57 300 -4.9 0 -4.8 -5 12/21/2005 06:10:00 0.8 0.3 1.5 0.4 0.6 0.3 1.5 0.4 0.6 0.3 1.1 0.4 58 0 57 300 -4.9 0 -4.6 -4.8 12/21/2005 06:20:00 0.5 0.3 1.9 0.4 0.5 0.3 1.5 0.4 0.4 0.2 1.5 0.4 58 0 58 300 -4.8 0 -4.6 -4.8 12/21/2005 06:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 58 0 300 300 -4.7 0 -4.6 -4.8 12/21/2005 06:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 58 0 300 300 -4.6 0 -4.6 -4.6 12/21/2005 06:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 58 0 300 300 -4.5 0 -4.4 -4.6 12/21/2005 07:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 58 0 300 300 -4.5 0 -4.4 -4.6 12/21/2005 07:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 58 0 300 300 -4.4 0 -4.4 -4.6 12/21/2005 07:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 58 0 300 300 -4.3 0 -4.4 -4.4 12/21/2005 07:30:00 0.4 0.1 0.7 0.4 0.4 0.1 1.1 0.4 0.4 0.2 1.1 0.4 58 0 57 300 -4.3 0 -4.4 -4.4 12/21/2005 07:40:00 0.4 0.1 0.7 0.4 0.4 0 0.4 0.4 0.4 0.1 1.1 0.4 58 0 58 300 -4.3 0 -4.4 -4.4 12/21/2005 07:50:00 0.4 0.1 0.7 0.4 0.4 0 0.7 0.4 0.4 0 0.7 0.4 58 0 57 300 -4.3 0 -4.4 -4.4 12/21/2005 08:00:00 0.4 0 0.7 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 58 0 57 300 -4.3 0 -4.2 -4.4 12/21/2005 08:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 58 0 300 300 -4.2 0 -4.2 -4.4 12/21/2005 08:20:00 0.7 0.4 1.5 0.4 0.5 0.2 1.5 0.4 0.5 0.2 1.1 0.4 58 0 57 300 -4.2 0 -3.9 -4.4 12/21/2005 08:30:00 0.7 0.3 1.5 0.4 0.5 0.2 1.1 0.4 0.4 0.2 1.5 0.4 58 0 57 300 -4 0 -3.9 -4.4 12/21/2005 08:40:00 0.8 0.3 1.5 0.4 0.6 0.3 1.5 0.4 0.5 0.3 1.1 0.4 58 0 57 300 -4 0 -3.9 -3.9 12/21/2005 08:50:00 0.7 0.3 1.5 0.4 0.6 0.3 1.5 0.4 0.6 0.2 1.1 0.4 58 0 58 300 -3.9 0 -3.7 -3.9 12/21/2005 09:00:00 0.8 0.4 1.9 0.4 0.6 0.3 1.5 0.4 0.6 0.3 1.5 0.4 58 0 57 300 -3.9 0 -3.7 -3.9 12/21/2005 09:10:00 0.6 0.3 1.5 0.4 0.4 0.2 1.1 0.4 0.5 0.2 1.1 0.4 58 0 58 300 -3.8 0 -3.7 -3.9 12/21/2005 09:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 58 0 300 300 -3.8 0 -3.7 -3.9 12/21/2005 09:30:00 0.4 0.1 1.1 0.4 0.4 0 0.4 0.4 0.4 0.1 0.7 0.4 58 0 57 300 -3.8 0 -3.7 -3.7 12/21/2005 09:40:00 0.7 0.3 1.1 0.4 0.6 0.3 1.1 0.4 0.6 0.2 1.1 0.4 58 0 57 300 -3.8 0 -3.7 -3.7 12/21/2005 09:50:00 0.7 0.3 1.5 0.4 0.5 0.2 1.1 0.4 0.5 0.2 1.1 0.4 58 0 57 300 -3.8 0 -3.7 -3.7 12/21/2005 10:00:00 0.4 0.2 1.1 0.4 0.4 0.1 1.1 0.4 0.4 0.1 0.7 0.4 58 0 58 300 -3.8 0 -3.5 -3.7 12/21/2005 10:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 58 0 300 300 -3.7 0 -3.5 -3.7 12/21/2005 10:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 58 0 300 300 -3.6 0 -3.5 -3.7 12/21/2005 10:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 58 0 300 300 -3.6 0 -3.5 -3.5 12/21/2005 10:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 58 0 300 300 -3.6 0 -3.5 -3.5 12/21/2005 10:50:00 0.4 0 0.7 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 58 0 57 300 -3.5 0 -3.5 -3.5 12/21/2005 11:00:00 0.4 0 0.7 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 58 0 58 300 -3.5 0 -3.5 -3.5 12/21/2005 11:10:00 0.6 0.3 1.1 0.4 0.5 0.2 1.1 0.4 0.5 0.2 1.1 0.4 58 0 57 300 -3.5 0 -3.5 -3.5 12/21/2005 11:20:00 0.7 0.3 1.1 0.4 0.6 0.3 1.5 0.4 0.5 0.2 1.1 0.4 58 0 57 300 -3.4 0 -3.3 -3.5 12/21/2005 11:30:00 0.6 0.3 1.1 0.4 0.5 0.3 1.5 0.4 0.5 0.3 1.1 0.4 58 0 57 300 -3.4 0 -3.3 -3.5 12/21/2005 11:40:00 0.4 0.2 1.1 0.4 0.4 0.1 1.1 0.4 0.4 0.2 0.7 0.4 58 0 58 300 -3.4 0 -3.3 -3.5 12/21/2005 11:50:00 0.4 0 0.7 0.4 0.4 0 0.4 0.4 0.4 0 0.7 0.4 58 0 57 300 -3.2 0 -3.3 -3.3 12/21/2005 12:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 58 0 300 300 -3.2 0 -3.3 -3.3 12/21/2005 12:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 58 0 300 300 -3.2 0 -3.3 -3.3 12/21/2005 12:20:00 0.4 0 0.7 0.4 0.4 0 0.4 0.4 0.4 0 0.7 0.4 58 0 58 300 -3.2 0 -3.3 -3.3 12/21/2005 12:30:00 0.4 0.1 1.1 0.4 0.4 0 0.4 0.4 0.4 0.1 0.7 0.4 58 0 58 300 -3.2 0 -3 -3.3 12/21/2005 12:40:00 0.6 0.3 1.1 0.4 0.4 0.2 1.1 0.4 0.5 0.2 1.1 0.4 58 0 58 300 -3.2 0 -3 -3.3 12/21/2005 12:50:00 0.4 0.2 1.1 0.4 0.4 0 0.4 0.4 0.4 0.1 1.1 0.4 58 0 58 300 -3.1 0 -3 -3.3 12/21/2005 13:00:00 0.4 0.2 1.1 0.4 0.4 0 0.7 0.4 0.4 0.2 0.7 0.4 58 0 57 300 -3.1 0 -3 -3.3 12/21/2005 13:10:00 0.5 0.2 1.1 0.4 0.4 0.1 0.7 0.4 0.5 0.2 1.1 0.4 58 0 58 300 -3.1 0 -2.8 -3.3 12/21/2005 13:20:00 0.7 0.3 1.5 0.4 0.7 0.3 1.5 0.4 0.7 0.3 1.5 0.4 58 0 58 300 -3 0 -2.8 -3 12/21/2005 13:30:00 0.6 0.3 1.5 0.4 0.5 0.2 1.1 0.4 0.5 0.2 1.1 0.4 58 0 58 300 -3 0 -2.8 -3 12/21/2005 13:40:00 0.8 0.3 1.5 0.4 0.5 0.2 1.1 0.4 0.5 0.2 1.1 0.4 58 0 58 300 -3 0 -2.8 -3 12/21/2005 13:50:00 0.9 0.4 1.9 0.4 0.7 0.4 1.5 0.4 0.7 0.3 1.5 0.4 58 0 58 300 -3 0 -2.8 -3 12/21/2005 14:00:00 0.6 0.4 1.5 0.4 0.5 0.3 1.5 0.4 0.5 0.2 1.1 0.4 58 0 58 300 -2.8 0 -2.8 -2.8 12/21/2005 14:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 58 0 300 300 -2.8 0 -2.6 -2.8 12/21/2005 14:20:00 0.7 0.3 1.5 0.4 0.6 0.3 1.5 0.4 0.5 0.2 1.1 0.4 58 0 58 300 -2.8 0 -2.6 -2.8 12/21/2005 14:30:00 1 0.2 1.5 0.4 0.9 0.3 1.5 0.4 0.8 0.3 1.5 0.4 58 0 58 300 -2.6 0 -2.6 -2.8 12/21/2005 14:40:00 0.6 0.3 1.5 0.4 0.5 0.3 1.5 0.4 0.5 0.3 1.1 0.4 58 0 59 300 -2.7 0 -2.6 -2.8 12/21/2005 14:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 58 0 300 300 -2.6 0 -2.6 -2.8 12/21/2005 15:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 58 0 300 300 -2.6 0 -2.6 -2.8 12/21/2005 15:10:00 0.6 0.3 1.5 0.4 0.5 0.3 1.5 0.4 0.6 0.3 1.5 0.4 58 0 58 300 -2.6 0 -2.6 -2.6 12/21/2005 15:20:00 0.4 0.1 1.1 0.4 0.4 0 0.7 0.4 0.4 0.1 1.1 0.4 58 0 58 300 -2.6 0 -2.6 -2.6 12/21/2005 15:30:00 0.4 0 0.7 0.4 0.4 0 0.4 0.4 0.4 0.1 0.7 0.4 58 0 59 300 -2.6 0 -2.6 -2.6 12/21/2005 15:40:00 0.4 0.1 0.7 0.4 0.4 0 0.4 0.4 0.4 0.1 0.7 0.4 58 0 58 300 -2.6 0 -2.6 -2.6 12/21/2005 15:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 58 0 300 300 -2.6 0 -2.6 -2.8 12/21/2005 16:00:00 0.4 0 0.7 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 58 0 58 300 -2.6 0 -2.6 -2.8 12/21/2005 16:10:00 0.6 0.4 1.9 0.4 0.5 0.3 1.5 0.4 0.5 0.3 1.5 0.4 58 0 58 300 -2.6 0 -2.6 -2.8 12/21/2005 16:20:00 1.2 0.5 1.9 0.4 1.1 0.5 1.9 0.4 0.9 0.4 1.9 0.4 58 0 58 300 -2.6 0 -2.6 -2.6 12/21/2005 16:30:00 0.9 0.4 1.9 0.4 0.8 0.4 1.9 0.4 0.7 0.3 1.5 0.4 58 0 59 300 -2.6 0 -2.6 -2.8 12/21/2005 16:40:00 0.7 0.4 1.9 0.4 0.7 0.5 1.9 0.4 0.6 0.4 1.9 0.4 58 0 58 300 -2.6 0 -2.6 -2.8 12/21/2005 16:50:00 1.5 0.3 2.3 0.7 1.3 0.4 2.3 0.4 0.9 0.4 1.9 0.4 58 0 58 300 -2.7 0 -2.6 -2.8 12/21/2005 17:00:00 0.9 0.4 1.9 0.4 0.8 0.4 1.5 0.4 0.5 0.2 1.1 0.4 58 0 57 300 -2.7 0 -2.6 -2.8 12/21/2005 17:10:00 0.8 0.4 1.5 0.4 0.8 0.4 1.5 0.4 0.6 0.4 1.5 0.4 58 0 57 300 -2.7 0 -2.6 -2.8 12/21/2005 17:20:00 0.4 0.2 1.1 0.4 0.4 0.1 1.1 0.4 0.4 0.1 1.1 0.4 58 0 57 300 -2.7 0 -2.6 -2.8 12/21/2005 17:30:00 0.9 0.3 1.5 0.4 0.8 0.3 1.5 0.4 0.6 0.3 1.5 0.4 58 0 58 300 -2.7 0 -2.6 -2.8 12/21/2005 17:40:00 0.6 0.2 1.1 0.4 0.6 0.3 1.1 0.4 0.4 0.1 0.7 0.4 58 0 58 300 -2.8 0 -2.6 -2.8 12/21/2005 17:50:00 0.8 0.5 1.9 0.4 0.8 0.4 1.9 0.4 0.6 0.4 1.9 0.4 58 0 58 300 -2.8 0 -2.6 -2.8 12/21/2005 18:00:00 0.6 0.3 1.5 0.4 0.6 0.3 1.5 0.4 0.4 0.2 1.1 0.4 58 0 58 300 -2.7 0 -2.6 -2.8 12/21/2005 18:10:00 0.9 0.3 1.5 0.4 0.9 0.3 1.5 0.4 0.6 0.2 1.1 0.4 58 0 58 300 -2.7 0 -2.6 -2.8 12/21/2005 18:20:00 0.6 0.3 1.5 0.4 0.6 0.3 1.5 0.4 0.4 0.1 1.1 0.4 58 0 58 300 -2.6 0 -2.6 -2.8 12/21/2005 18:30:00 0.7 0.3 1.1 0.4 0.6 0.4 1.5 0.4 0.4 0.2 1.1 0.4 58 0 58 300 -2.6 0 -2.6 -2.8 12/21/2005 18:40:00 1 0.4 1.9 0.4 0.9 0.5 1.9 0.4 0.5 0.3 1.1 0.4 58 0 59 300 -2.6 0 -2.6 -2.6 12/21/2005 18:50:00 0.9 0.5 1.9 0.4 0.9 0.5 2.3 0.4 0.5 0.3 1.5 0.4 58 0 58 300 -2.6 0 -2.6 -2.6 12/21/2005 19:00:00 0.8 0.4 1.9 0.4 0.7 0.4 1.9 0.4 0.7 0.4 1.5 0.4 58 0 58 300 -2.6 0 -2.6 -2.6 12/21/2005 19:10:00 0.7 0.4 1.5 0.4 0.6 0.4 1.5 0.4 0.6 0.4 1.5 0.4 58 0 59 300 -2.6 0 -2.6 -2.6 12/21/2005 19:20:00 0.4 0.1 0.7 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 58 0 58 300 -2.5 0 -2.4 -2.6 12/21/2005 19:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 58 0 300 300 -2.4 0 -2.4 -2.6 12/21/2005 19:40:00 0.7 0.4 1.9 0.4 0.8 0.4 1.9 0.4 0.7 0.4 1.5 0.4 58 0 58 300 -2.4 0 -2.4 -2.6 12/21/2005 19:50:00 0.7 0.3 1.5 0.4 0.5 0.2 1.1 0.4 0.5 0.2 1.1 0.4 58 0 58 300 -2.4 0 -2.4 -2.6 12/21/2005 20:00:00 0.4 0.1 0.7 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 58 0 58 300 -2.5 0 -2.4 -2.6 12/21/2005 20:10:00 0.6 0.3 1.1 0.4 0.4 0.1 1.1 0.4 0.4 0.1 0.7 0.4 59 0 58 300 -2.5 0 -2.4 -2.6 12/21/2005 20:20:00 0.5 0.2 1.1 0.4 0.4 0.2 1.1 0.4 0.4 0.1 1.1 0.4 59 0 59 300 -2.5 0 -2.4 -2.6 12/21/2005 20:30:00 0.4 0.2 1.1 0.4 0.4 0.2 1.5 0.4 0.5 0.3 1.5 0.4 59 0 59 300 -2.5 0 -2.4 -2.6 12/21/2005 20:40:00 0.7 0.4 1.5 0.4 0.7 0.4 1.5 0.4 0.9 0.3 1.5 0.4 59 0 59 300 -2.4 0 -2.4 -2.6 12/21/2005 20:50:00 0.6 0.3 1.5 0.4 0.5 0.2 1.1 0.4 0.5 0.2 1.1 0.4 59 0 59 300 -2.4 0 -2.4 -2.6 12/21/2005 21:00:00 0.9 0.3 1.5 0.4 0.8 0.4 1.5 0.4 0.5 0.2 1.1 0.4 59 0 58 300 -2.4 0 -2.4 -2.6 12/21/2005 21:10:00 1.1 0.3 1.9 0.4 1 0.3 1.9 0.4 0.7 0.3 1.5 0.4 59 0 59 300 -2.4 0 -2.4 -2.6 12/21/2005 21:20:00 1.4 0.4 2.3 0.4 1.4 0.4 2.3 0.4 0.9 0.3 1.5 0.4 59 0 59 300 -2.4 0 -2.4 -2.6 12/21/2005 21:30:00 1.3 0.4 2.3 0.4 1.3 0.4 2.3 0.4 0.8 0.3 1.5 0.4 59 0 59 300 -2.5 0 -2.4 -2.6 12/21/2005 21:40:00 1.2 0.3 1.9 0.7 1.2 0.4 1.9 0.4 0.9 0.4 1.9 0.4 59 0 59 300 -2.5 0 -2.4 -2.6 12/21/2005 21:50:00 0.9 0.3 1.5 0.4 0.8 0.4 1.5 0.4 0.7 0.2 1.1 0.4 59 0 59 300 -2.4 0 -2.4 -2.6 12/21/2005 22:00:00 0.5 0.2 1.1 0.4 0.4 0.1 1.1 0.4 0.7 0.2 1.1 0.4 59 0 59 300 -2.4 0 -2.4 -2.6 12/21/2005 22:10:00 0.4 0.2 1.1 0.4 0.4 0.1 0.7 0.4 0.7 0.3 1.1 0.4 59 0 59 300 -2.4 0 -2.4 -2.6 12/21/2005 22:20:00 0.5 0.2 1.1 0.4 0.5 0.2 1.1 0.4 0.5 0.2 1.1 0.4 59 0 59 300 -2.5 0 -2.4 -2.6 12/21/2005 22:30:00 0.6 0.4 1.9 0.4 0.5 0.4 1.9 0.4 0.7 0.3 1.5 0.4 59 0 59 300 -2.4 0 -2.4 -2.6 12/21/2005 22:40:00 0.6 0.3 1.5 0.4 0.5 0.3 1.5 0.4 0.5 0.2 1.1 0.4 59 0 59 300 -2.4 0 -2.4 -2.6 12/21/2005 22:50:00 0.7 0.3 1.5 0.4 0.6 0.3 1.5 0.4 0.5 0.2 1.1 0.4 59 0 59 300 -2.5 0 -2.4 -2.6 12/21/2005 23:00:00 0.7 0.4 1.5 0.4 0.6 0.4 1.5 0.4 0.4 0.2 1.1 0.4 59 0 59 300 -2.6 0 -2.4 -2.6 12/21/2005 23:10:00 0.7 0.3 1.5 0.4 0.6 0.3 1.5 0.4 0.4 0 0.4 0.4 59 0 59 300 -2.6 0 -2.6 -2.6 12/21/2005 23:20:00 0.6 0.2 1.1 0.4 0.4 0.2 1.1 0.4 0.4 0.1 0.7 0.4 59 0 59 300 -2.6 0 -2.6 -2.6 12/21/2005 23:30:00 0.9 0.3 1.5 0.4 0.9 0.3 1.5 0.4 0.4 0.2 1.1 0.4 59 0 59 300 -2.7 0 -2.6 -2.8 12/21/2005 23:40:00 0.4 0.1 0.7 0.4 0.4 0.1 0.7 0.4 0.4 0 0.7 0.4 59 0 59 300 -2.8 0 -2.6 -2.8 12/21/2005 23:50:00 0.6 0.3 1.1 0.4 0.5 0.3 1.5 0.4 0.4 0 0.4 0.4 59 0 59 300 -2.6 0 -2.6 -2.8 12/22/2005 00:00:00 0.9 0.4 1.5 0.4 0.9 0.4 1.5 0.4 0.4 0.1 1.1 0.4 59 0 59 300 -2.6 0 -2.6 -2.8 12/22/2005 00:10:00 1.7 0.4 2.3 0.7 1.7 0.4 2.3 0.7 0.8 0.4 1.9 0.4 59 0 60 300 -2.8 0 -2.6 -2.8 12/22/2005 00:20:00 1.7 0.6 2.6 0.4 1.7 0.6 2.6 0.4 1 0.5 1.9 0.4 60 0 60 300 -2.8 0 -2.6 -2.8 12/22/2005 00:30:00 0.5 0.3 1.1 0.4 0.5 0.2 1.5 0.4 0.4 0 0.4 0.4 60 0 60 300 -3 0 -2.8 -3 12/22/2005 00:40:00 1 0.3 1.5 0.4 0.9 0.4 1.9 0.4 0.6 0.3 1.5 0.4 60 0 60 300 -2.9 0 -2.8 -3 12/22/2005 00:50:00 0.5 0.3 1.5 0.4 0.5 0.2 1.1 0.4 0.4 0.2 1.1 0.4 60 0 60 300 -2.9 0 -2.8 -3.3 12/22/2005 01:00:00 1 0.4 1.9 0.4 0.9 0.4 1.9 0.4 0.8 0.4 1.9 0.4 60 0 60 300 -3.1 0 -2.8 -3.3 12/22/2005 01:10:00 0.9 0.4 1.5 0.4 0.6 0.3 1.5 0.4 0.7 0.3 1.5 0.4 60 0 60 300 -3.1 0 -3 -3.3 12/22/2005 01:20:00 1.4 0.6 2.3 0.4 1.2 0.6 2.3 0.4 1 0.5 1.9 0.4 60 0 60 300 -3.1 0 -2.8 -3.3 12/22/2005 01:30:00 1.3 0.4 2.3 0.7 1.2 0.4 1.9 0.4 1 0.3 1.5 0.4 60 0 60 300 -3.1 0 -2.8 -3.3 12/22/2005 01:40:00 1.2 0.4 1.9 0.4 0.9 0.4 1.5 0.4 0.8 0.3 1.5 0.4 60 0 60 300 -3.3 0 -3 -3.5 12/22/2005 01:50:00 1 0.5 2.3 0.4 0.8 0.5 1.9 0.4 0.7 0.4 1.5 0.4 277 47 60 300 -3.3 0 -3.3 -3.5 12/22/2005 02:00:00 0.5 0.3 1.5 0.4 0.4 0.2 1.1 0.4 0.5 0.2 1.1 0.4 304 28 243 300 -3.5 0.2 -3.3 -3.7 12/22/2005 02:10:00 0.9 0.5 1.9 0.4 0.7 0.4 1.5 0.4 0.6 0.3 1.5 0.4 241 12 249 300 -3.5 0 -3.3 -3.7 12/22/2005 02:20:00 0.8 0.6 2.3 0.4 0.7 0.5 2.3 0.4 0.6 0.3 1.5 0.4 238 2 238 300 -3.5 0.1 -3.3 -3.7 12/22/2005 02:30:00 2.6 0.5 3.4 0.7 2.5 0.4 3 1.1 2 0.6 2.6 0.4 237 8 225 300 -3.7 0 -3.5 -3.7 12/22/2005 02:40:00 1.9 0.7 3 0.4 1.8 0.7 3 0.4 1.2 0.7 2.6 0.4 249 14 263 300 -3.4 0.2 -3.3 -3.7 12/22/2005 02:50:00 2 0.6 3 0.4 1.8 0.6 3 0.4 1.3 0.4 2.3 0.4 263 17 266 300 -3.4 0.1 -3.3 -3.5 12/22/2005 03:00:00 2.2 0.4 3 1.1 2 0.5 3 1.1 1.5 0.5 2.6 0.4 236 6 229 300 -3.3 0 -3 -3.9 12/22/2005 03:10:00 2.5 0.4 3.8 1.9 2.4 0.4 3.4 1.5 1.6 0.4 2.3 0.7 255 7 261 300 -3.2 0.1 -2.8 -3.5 12/22/2005 03:20:00 2.5 0.4 3.8 1.5 2.4 0.4 3.4 1.5 1.8 0.4 3 1.1 259 6 260 300 -2.8 0 -2.6 -3 12/22/2005 03:30:00 3.1 0.8 5.3 1.5 3 0.8 5.3 1.5 2.4 0.8 4.6 0.7 248 11 257 300 -2.4 0.2 -2.1 -2.6 12/22/2005 03:40:00 2.7 0.5 4.2 1.1 2.5 0.6 3.8 1.1 1.9 0.5 3.4 0.4 253 14 251 300 -2.1 0 -2.1 -2.1 12/22/2005 03:50:00 2.7 0.4 3.4 1.9 2.5 0.4 3.4 1.5 1.9 0.5 3 0.4 255 10 256 300 -2.1 0 -1.9 -2.1 12/22/2005 04:00:00 2.2 0.5 3.4 1.1 2 0.6 3.4 0.7 1.5 0.4 2.6 0.7 271 9 268 300 -2 0 -1.9 -2.1 12/22/2005 04:10:00 1.2 0.6 2.6 0.4 1.1 0.6 2.6 0.4 0.7 0.4 1.5 0.4 297 11 299 300 -2 0 -1.9 -2.1 12/22/2005 04:20:00 2 0.3 2.6 1.5 2 0.4 3 0.7 1.5 0.3 2.3 0.7 339 19 328 300 -2.1 0 -2.1 -2.1 12/22/2005 04:30:00 2.9 0.6 4.6 1.5 2.8 0.5 4.6 1.5 1.6 0.5 2.6 0.4 11 13 21 300 -2.1 0 -2.1 -2.1 12/22/2005 04:40:00 4.7 0.8 6.8 2.6 4.4 0.9 6.8 2.3 2.5 0.7 4.9 1.1 37 11 33 300 -2.1 0.1 -1.7 -2.4 12/22/2005 04:50:00 5.3 1 7.6 2.3 5.1 1 7.6 1.9 3.2 1 5.7 0.7 45 10 43 300 -1.4 0.1 -1.2 -1.7 12/22/2005 05:00:00 2.1 0.9 4.9 0.4 2 1 4.6 0.4 1.7 0.5 3.8 0.4 88 41 33 300 -1.3 0 -1.2 -1.4 12/22/2005 05:10:00 2 0.5 3 0.7 2.1 0.5 3 0.7 2.1 0.5 3 0.4 190 11 181 300 -1.8 0.2 -1.4 -2.1 12/22/2005 05:20:00 1.4 0.6 2.6 0.4 1.2 0.6 2.6 0.4 1.2 0.5 2.3 0.4 240 15 256 300 -2.1 0 -1.9 -2.1 12/22/2005 05:30:00 2.4 0.5 3.8 1.5 2.3 0.6 3.4 1.5 2 0.5 3 0.7 260 11 264 300 -1.9 0 -1.7 -2.1 12/22/2005 05:40:00 2.5 0.5 3.4 1.5 2.4 0.5 3.4 1.1 2.1 0.5 3 0.7 280 9 264 300 -1.5 0 -1.2 -1.7 12/22/2005 05:50:00 1 0.6 2.6 0.4 0.9 0.6 2.6 0.4 1 0.6 2.6 0.4 323 14 314 300 -1.3 0 -1.2 -1.4 12/22/2005 06:00:00 1.5 1.1 4.2 0.4 1.2 1 3.8 0.4 0.7 0.5 2.6 0.4 18 23 21 300 -1.3 0 -1.2 -1.4 12/22/2005 06:10:00 2 1 4.6 0.4 1.7 0.9 4.6 0.4 1.1 0.6 2.6 0.4 45 22 17 300 -1.6 0 -1.2 -1.7 12/22/2005 06:20:00 1.6 0.9 3.4 0.4 1.4 0.8 3.4 0.4 0.6 0.4 2.3 0.4 38 17 27 300 -1.6 0 -1.4 -1.7 12/22/2005 06:30:00 3.9 0.7 5.7 1.9 3.3 0.7 4.9 1.1 2 0.5 3.8 0.7 28 13 38 300 -1.3 0 -1.2 -1.4 12/22/2005 06:40:00 4 0.7 5.7 1.5 3.6 0.7 5.7 1.5 2.5 0.7 4.6 1.1 22 12 20 300 -0.3 0.4 0.2 -1.2 12/22/2005 06:50:00 4.2 0.9 6.8 2.3 3.8 0.9 6.8 1.9 2.7 0.9 5.7 0.4 22 11 19 300 0.4 0.2 0.9 0.2 12/22/2005 07:00:00 5 0.9 7.6 3 4.4 0.9 6.8 2.3 3.4 0.9 6.8 1.5 24 12 20 300 1.1 0 1.4 0.9 12/22/2005 07:10:00 3.9 0.9 6.5 1.9 3.6 0.8 6.1 1.5 2.8 0.9 5.7 1.1 27 15 27 300 1.3 0 1.6 1.4 12/22/2005 07:20:00 1.7 0.9 4.6 0.4 1.5 0.9 4.2 0.4 1.3 0.6 3 0.4 79 72 33 300 0.8 0.6 1.6 -0.5 12/22/2005 07:30:00 0.7 0.5 2.6 0.4 0.7 0.5 2.3 0.4 0.8 0.6 2.6 0.4 85 56 3 300 -1 0.2 -0.5 -1.2 12/22/2005 07:40:00 0.8 0.5 2.6 0.4 0.7 0.5 2.6 0.4 0.9 0.6 2.6 0.4 97 64 180 300 -1.2 0 -1 -1.4 12/22/2005 07:50:00 0.7 0.4 2.6 0.4 0.5 0.4 2.3 0.4 0.6 0.4 1.9 0.4 13 39 319 300 -1 0.1 -0.7 -1.2 12/22/2005 08:00:00 0.8 0.7 3.4 0.4 0.7 0.6 3 0.4 0.5 0.3 1.9 0.4 335 76 30 300 -0.6 0.1 -0.5 -0.7 12/22/2005 08:10:00 0.5 0.3 1.9 0.4 0.4 0.2 1.9 0.4 0.4 0.1 1.1 0.4 141 102 100 300 -0.2 0.2 0.2 -0.5 12/22/2005 08:20:00 0.9 0.6 2.3 0.4 0.9 0.7 2.3 0.4 1.5 0.7 2.6 0.4 151 69 200 300 -0.5 0.3 0.2 -1 12/22/2005 08:30:00 0.8 0.4 1.9 0.4 0.9 0.5 1.9 0.4 1 0.4 1.9 0.4 196 19 199 300 -1 0 -0.7 -1.2 12/22/2005 08:40:00 1.8 0.7 3 0.4 1.7 0.7 3 0.4 1.5 0.6 2.6 0.4 183 7 189 300 -1 0 -0.7 -1.2 12/22/2005 08:50:00 1.5 0.4 2.3 0.7 1.7 0.4 2.6 0.7 1.3 0.4 2.3 0.4 194 14 202 300 -1.2 0 -1 -1.2 12/22/2005 09:00:00 1 0.4 1.9 0.4 0.9 0.5 1.9 0.4 0.9 0.5 1.9 0.4 187 10 172 300 -1.3 0 -1.2 -1.4 12/22/2005 09:10:00 0.6 0.3 1.5 0.4 0.5 0.2 1.5 0.4 0.4 0.2 1.1 0.4 115 72 49 300 -1.3 0 -1.2 -1.4 12/22/2005 09:20:00 1.1 0.7 3.4 0.4 0.9 0.8 3.8 0.4 0.8 0.5 2.6 0.4 40 22 82 300 -1 0 -1 -1.2 12/22/2005 09:30:00 1.4 0.5 2.6 0.4 1.3 0.6 2.6 0.4 0.9 0.5 2.6 0.4 44 16 39 300 -1 0 -0.7 -1.2 12/22/2005 09:40:00 1.3 0.7 3 0.4 1.2 0.7 3.4 0.4 0.9 0.5 2.3 0.4 78 18 100 300 -0.8 0 -0.5 -1 12/22/2005 09:50:00 2.2 0.6 4.2 1.1 2.1 0.6 3.8 0.7 1.5 0.5 3 0.4 44 15 34 300 -0.6 0.2 -0.3 -1 12/22/2005 10:00:00 2.3 0.6 4.2 1.1 2.1 0.7 4.2 0.7 1.6 0.7 3.8 0.4 36 8 40 300 -0.3 0 -0.1 -0.5 12/22/2005 10:10:00 2.8 0.6 4.2 1.1 2.5 0.6 3.8 0.7 1.9 0.6 3.4 0.4 32 9 36 300 -0.2 0 -0.1 -0.3 12/22/2005 10:20:00 1.8 0.6 3 0.4 1.6 0.8 3.4 0.4 1.1 0.6 2.6 0.4 39 13 39 300 -0.2 0 -0.1 -0.3 12/22/2005 10:30:00 0.7 0.4 1.9 0.4 0.6 0.4 1.9 0.4 0.4 0.2 1.1 0.4 32 36 45 300 -0.5 0 -0.3 -0.7 12/22/2005 10:40:00 2 0.5 3 0.7 1.8 0.6 3.4 0.4 1.2 0.5 3 0.4 27 13 8 300 -0.4 0.2 -0.1 -0.7 12/22/2005 10:50:00 2.2 0.6 3.8 0.7 2 0.6 3.4 0.7 1.3 0.6 3 0.4 22 9 23 300 -0.1 0 0.2 -0.1 12/22/2005 11:00:00 1.2 0.5 2.6 0.4 1 0.6 2.6 0.4 1 0.5 2.3 0.4 5 9 357 300 0.1 0 0.2 -0.3 12/22/2005 11:10:00 0.6 0.3 1.5 0.4 0.5 0.2 1.5 0.4 0.4 0.1 1.1 0.4 357 8 355 300 0.2 0 0.2 0.2 12/22/2005 11:20:00 0.6 0.3 1.5 0.4 0.4 0.2 1.5 0.4 0.4 0.1 1.1 0.4 337 13 355 300 0.4 0 0.4 0.2 12/22/2005 11:30:00 0.8 0.4 1.9 0.4 0.7 0.4 1.9 0.4 0.6 0.4 1.9 0.4 359 18 356 300 0.5 0 0.7 0.4 12/22/2005 11:40:00 0.6 0.3 1.5 0.4 0.4 0.2 1.1 0.4 0.5 0.3 1.5 0.4 10 7 12 300 0.7 0 0.7 0.7 12/22/2005 11:50:00 0.5 0.2 1.1 0.4 0.4 0.1 1.1 0.4 0.4 0.1 1.1 0.4 44 8 46 300 0.7 0 0.7 0.7 12/22/2005 12:00:00 0.6 0.3 1.1 0.4 0.4 0.2 1.1 0.4 0.5 0.2 1.1 0.4 46 0 46 300 0.6 0 0.7 0.4 12/22/2005 12:10:00 0.6 0.2 1.1 0.4 0.4 0.2 1.1 0.4 0.5 0.2 1.1 0.4 46 0 46 300 0.2 0.1 0.7 -0.1 12/22/2005 12:20:00 0.4 0.1 0.7 0.4 0.4 0 0.4 0.4 0.4 0.2 1.1 0.4 46 0 46 300 -0.2 0 -0.1 -0.3 12/22/2005 12:30:00 0.4 0.2 1.1 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 46 0 46 300 -0.2 0 -0.1 -0.3 12/22/2005 12:40:00 0.5 0.2 1.1 0.4 0.4 0.1 0.7 0.4 0.4 0 0.4 0.4 46 0 46 300 -0.1 0 -0.1 -0.1 12/22/2005 12:50:00 0.5 0.2 1.1 0.4 0.4 0.1 0.7 0.4 0.4 0 0.4 0.4 46 0 47 300 0 0 0.2 -0.1 12/22/2005 13:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 46 0 300 300 0.4 0.2 0.9 0.2 12/22/2005 13:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 46 0 300 300 0.7 0 0.9 0.7 12/22/2005 13:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 46 0 300 300 0.5 0 0.7 0.4 12/22/2005 13:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 46 0 300 300 0.4 0 0.7 0.2 12/22/2005 13:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 46 0 300 300 0.4 0 0.4 0.2 12/22/2005 13:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 46 0 300 300 0.2 0 0.4 0.2 12/22/2005 14:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 46 0 300 300 0.1 0 0.2 -0.1 12/22/2005 14:10:00 0.4 0.2 1.1 0.4 0.4 0 0.4 0.4 0.7 0.3 1.1 0.4 46 0 46 300 -0.1 0 0.2 -0.1 12/22/2005 14:20:00 0.6 0.3 1.5 0.4 0.5 0.2 1.1 0.4 0.8 0.3 1.5 0.4 46 0 46 300 -0.2 0 -0.1 -0.3 12/22/2005 14:30:00 0.5 0.3 1.1 0.4 0.4 0.2 1.1 0.4 0.8 0.3 1.5 0.4 44 3 46 300 -0.3 0 -0.1 -0.5 12/22/2005 14:40:00 0.4 0.1 0.7 0.4 0.4 0 0.7 0.4 0.4 0.2 1.1 0.4 41 0 41 300 -0.5 0 -0.5 -0.5 12/22/2005 14:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 41 0 300 300 -0.8 0.1 -0.5 -1 12/22/2005 15:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 41 0 300 300 -1 0 -0.7 -1.2 12/22/2005 15:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 41 0 300 300 -1.3 0.1 -1 -1.4 12/22/2005 15:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 41 0 300 300 -1.4 0 -1.2 -1.4 12/22/2005 15:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 41 0 300 300 -1.5 0 -1.2 -1.4 12/22/2005 15:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 41 0 300 300 -1.4 0 -1.2 -1.4 12/22/2005 15:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 41 0 300 300 -1.6 0 -1.4 -1.4 12/22/2005 16:00:00 0.4 0.1 0.7 0.4 0.4 0 0.4 0.4 0.4 0.2 1.1 0.4 41 0 41 300 -1.6 0 -1.4 -1.4 12/22/2005 16:10:00 0.4 0.1 0.7 0.4 0.4 0 0.7 0.4 0.4 0.1 0.7 0.4 41 0 41 300 -1.8 0.1 -1.4 -2.1 12/22/2005 16:20:00 0.7 0.2 1.1 0.4 0.5 0.2 1.1 0.4 0.4 0.1 0.7 0.4 41 0 41 300 -2.1 0 -1.9 -2.1 12/22/2005 16:30:00 1.1 0.2 1.5 0.7 1 0.2 1.5 0.7 0.7 0.3 1.1 0.4 48 6 41 300 -2.3 0 -2.1 -2.6 12/22/2005 16:40:00 1.5 0.4 2.3 0.7 1.4 0.4 2.3 0.7 1.1 0.3 1.9 0.4 44 7 38 300 -2.5 0 -2.4 -2.6 12/22/2005 16:50:00 2.1 0.3 3 1.5 2 0.3 2.6 1.5 1.6 0.3 2.3 0.7 35 0 36 300 -2.5 0 -2.4 -2.6 12/22/2005 17:00:00 2.7 0.2 3.4 2.3 2.7 0.2 3.4 2.3 2.1 0.4 3 1.1 42 3 43 300 -2.8 0 -2.6 -2.8 12/22/2005 17:10:00 2.3 0.2 2.6 1.9 2.3 0.2 2.6 1.5 1.3 0.3 1.9 0.7 37 5 36 300 -2.7 0 -2.6 -2.8 12/22/2005 17:20:00 2.6 0.3 3 1.5 2.5 0.4 3 1.5 1.7 0.4 2.3 0.7 41 4 38 300 -2.7 0 -2.6 -3 12/22/2005 17:30:00 2.4 0.3 3 1.5 2.4 0.4 3 1.1 1.6 0.3 2.3 0.7 40 4 35 300 -3.1 0 -2.8 -3.3 12/22/2005 17:40:00 2 0.3 2.6 1.5 2 0.3 2.6 1.1 1.3 0.2 1.9 0.7 50 4 54 300 -3.3 0 -3.3 -3.5 12/22/2005 17:50:00 2.6 0.3 3 1.9 2.6 0.2 3 1.9 2 0.2 2.3 1.5 52 2 51 300 -3.4 0.1 -3.3 -3.5 12/22/2005 18:00:00 2.7 0.2 3 2.3 2.7 0.2 3 2.3 1.8 0.3 2.3 1.1 42 5 40 300 -3.1 0.2 -2.8 -3.5 12/22/2005 18:10:00 2.8 0.2 3.4 2.3 2.8 0.2 3.4 2.3 1.9 0.3 2.6 1.1 41 2 43 300 -2.8 0 -2.6 -3 12/22/2005 18:20:00 2.9 0.2 3.4 2.6 2.8 0.2 3.4 2.3 1.7 0.3 2.3 1.1 37 2 34 300 -3.3 0.1 -3 -3.5 12/22/2005 18:30:00 3 0.2 3.4 2.6 3 0.2 3.4 2.6 1.9 0.4 2.6 1.1 38 3 33 300 -2.6 0.2 -2.4 -3 12/22/2005 18:40:00 2.9 0.2 3.4 2.3 2.8 0.2 3.4 2.3 1.9 0.4 2.6 1.1 41 6 40 300 -2.4 0.1 -2.1 -2.6 12/22/2005 18:50:00 3.2 0.2 3.8 2.6 3.2 0.2 3.8 2.6 1.8 0.3 2.6 1.1 35 1 35 300 -2.8 0 -2.6 -3 12/22/2005 19:00:00 3.4 0.2 3.8 3 3.4 0.2 3.8 3 2.1 0.3 2.6 1.5 37 2 35 300 -2.9 0 -2.6 -3 12/22/2005 19:10:00 3.4 0.2 3.8 2.6 3.3 0.2 3.8 2.6 2.3 0.3 3 1.5 40 2 43 300 -3.5 0.4 -2.8 -4.2 12/22/2005 19:20:00 3.2 0.2 3.8 2.3 3.1 0.3 3.8 2.3 1.9 0.3 2.6 1.1 33 3 37 300 -3.6 0.3 -3 -3.9 12/22/2005 19:30:00 3.3 0.2 3.8 2.6 3.1 0.2 3.8 2.6 1.8 0.3 2.6 1.1 30 2 35 300 -3 0 -2.8 -3 12/22/2005 19:40:00 3.4 0.2 4.2 3 3.2 0.2 3.8 2.6 1.9 0.3 2.6 1.1 29 2 30 300 -3.1 0 -2.8 -3.3 12/22/2005 19:50:00 3.1 0.2 3.8 2.6 3 0.2 3.4 2.3 1.8 0.2 2.3 1.1 31 2 31 300 -3.1 0 -3 -3.3 12/22/2005 20:00:00 3.1 0.2 3.4 2.6 2.9 0.2 3.4 2.3 1.7 0.3 2.3 1.1 28 2 33 300 -3 0 -2.8 -3 12/22/2005 20:10:00 2.9 0.2 3.4 2.3 2.5 0.3 3 1.9 1.6 0.2 2.3 0.7 24 1 29 300 -2.9 0.1 -2.8 -3.3 12/22/2005 20:20:00 3.1 0.2 3.4 2.6 2.9 0.2 3.4 2.3 1.9 0.3 2.6 1.1 28 3 27 300 -3.4 0.2 -3 -3.5 12/22/2005 20:30:00 3.3 0.2 3.8 2.6 3.2 0.3 3.8 2.3 2.1 0.3 2.6 1.1 32 2 28 300 -4.2 0.2 -3.5 -4.4 12/22/2005 20:40:00 3.6 0.3 4.2 3 3.4 0.3 4.2 2.6 2 0.3 3 1.1 29 3 32 300 -3.8 0.1 -3.5 -4.4 12/22/2005 20:50:00 3.7 0.2 4.2 3 3.5 0.3 4.2 2.6 2.1 0.3 3 1.5 28 4 27 300 -3.3 0 -3 -3.5 12/22/2005 21:00:00 3.5 0.2 4.2 3 3.2 0.3 3.8 2.6 2.1 0.3 3 1.5 28 4 25 300 -2.9 0 -2.6 -3.3 12/22/2005 21:10:00 3.5 0.2 4.2 3 3.3 0.2 3.8 2.6 2 0.3 3 1.1 31 6 22 300 -2.9 0.1 -2.6 -3 12/22/2005 21:20:00 3.2 0.2 3.4 2.6 3.1 0.2 3.4 2.6 1.9 0.3 2.6 1.1 37 6 33 300 -2.7 0.2 -2.6 -3 12/22/2005 21:30:00 3 0.2 3.4 2.6 2.9 0.2 3.4 2.3 2.1 0.5 3 1.5 29 5 22 300 -2.7 0 -2.6 -2.8 12/22/2005 21:40:00 3.4 0.2 4.2 2.6 3.4 0.4 4.2 2.3 2.5 0.4 3.4 1.1 14 5 13 300 -3 0.1 -2.8 -3.3 12/22/2005 21:50:00 3.3 0.2 3.8 2.6 3 0.3 3.8 2.6 2.3 0.4 3 1.1 20 4 15 300 -3.1 0 -3 -3.3 12/22/2005 22:00:00 3.1 0.2 3.8 2.6 3 0.3 3.4 2.3 2.2 0.4 3 1.1 21 6 21 300 -3.1 0 -3 -3.3 12/22/2005 22:10:00 2.9 0.2 3.4 2.3 2.7 0.3 3.4 2.3 2.2 0.3 2.6 1.1 28 7 27 300 -2.9 0.1 -2.6 -3.3 12/22/2005 22:20:00 3.1 0.2 3.4 2.6 2.8 0.3 3.4 2.3 2.1 0.3 3 1.1 24 4 24 300 -2.8 0.1 -2.6 -3 12/22/2005 22:30:00 3 0.2 3.4 2.3 2.8 0.3 3.4 1.9 2.1 0.4 3 1.1 19 5 20 300 -3.1 0 -3 -3.3 12/22/2005 22:40:00 3.4 0.2 3.8 3 3.1 0.3 3.8 2.3 2.1 0.4 3 1.1 26 6 31 300 -3.4 0.1 -3 -3.5 12/22/2005 22:50:00 3.1 0.3 3.8 2.3 2.9 0.3 3.4 1.9 2.1 0.4 3 1.1 22 7 28 300 -3.3 0 -3 -3.5 12/22/2005 23:00:00 3 0.2 3.4 2.3 2.7 0.3 3.4 1.9 1.8 0.4 3 1.1 25 5 22 300 -2.8 0 -2.6 -3.3 12/22/2005 23:10:00 3.3 0.3 4.2 2.6 3.3 0.3 4.2 2.6 2.2 0.4 3.4 1.5 12 4 10 300 -3.3 0.2 -2.8 -3.5 12/22/2005 23:20:00 3.4 0.3 4.2 2.3 3 0.4 4.2 2.3 2.1 0.5 3.4 0.7 19 5 14 300 -3.2 0 -3 -3.3 12/22/2005 23:30:00 3.3 0.2 3.8 2.6 2.9 0.2 3.4 1.9 1.9 0.4 3 0.7 22 3 24 300 -3 0.1 -2.6 -3.3 12/22/2005 23:40:00 3 0.3 3.8 2.3 2.9 0.4 3.8 1.9 1.9 0.4 2.6 0.7 16 4 17 300 -2.6 0 -2.6 -2.8 12/22/2005 23:50:00 3 0.3 3.8 2.3 2.7 0.3 3.4 1.5 1.6 0.3 2.3 1.1 21 4 27 300 -2.4 0 -2.1 -2.6 12/23/2005 00:00:00 2.7 0.4 3.4 1.5 2.5 0.3 3.4 1.5 1.5 0.4 2.3 0.7 18 4 26 300 -1.9 0 -1.7 -2.4 12/23/2005 00:10:00 1.3 0.5 2.3 0.4 1.2 0.5 2.6 0.4 0.5 0.2 1.1 0.4 14 4 12 300 -1.9 0 -1.7 -2.1 12/23/2005 00:20:00 1.3 0.4 2.3 0.4 1 0.4 2.3 0.4 0.4 0.2 1.1 0.4 27 6 25 300 -2.1 0.2 -1.9 -2.6 12/23/2005 00:30:00 0.9 0.4 1.5 0.4 0.7 0.4 1.5 0.4 0.4 0.1 1.1 0.4 33 4 22 300 -2.8 0.2 -2.6 -3.3 12/23/2005 00:40:00 0.5 0.3 1.5 0.4 0.4 0.2 1.5 0.4 1.1 0.4 1.9 0.4 282 66 236 300 -3.3 0 -3 -3.5 12/23/2005 00:50:00 1.9 0.4 2.6 0.7 1.7 0.4 2.3 0.7 1.5 0.4 2.3 0.7 244 4 245 300 -3.5 0 -3.3 -3.5 12/23/2005 01:00:00 1.7 0.3 2.3 1.1 1.4 0.3 1.9 0.7 1.1 0.3 1.5 0.4 244 5 239 300 -3.4 0 -3.3 -3.5 12/23/2005 01:10:00 1.5 0.2 1.9 1.1 1.3 0.2 1.9 0.7 1.2 0.2 1.5 0.7 246 6 250 300 -3.2 0 -3 -3.3 12/23/2005 01:20:00 2 0.4 2.6 1.5 1.8 0.5 2.6 1.1 1.6 0.4 2.6 0.7 238 10 229 300 -3 0 -2.8 -3.3 12/23/2005 01:30:00 2 0.5 2.6 0.7 1.8 0.6 2.6 0.4 1.4 0.6 2.6 0.4 258 17 237 300 -3 0 -2.8 -3 12/23/2005 01:40:00 1.2 0.3 1.9 0.7 1 0.4 1.5 0.4 0.8 0.3 1.5 0.4 307 10 315 300 -3 0 -2.8 -3 12/23/2005 01:50:00 0.9 0.5 1.9 0.4 0.7 0.4 1.9 0.4 0.5 0.2 1.1 0.4 313 3 311 300 -3.1 0 -3 -3.3 12/23/2005 02:00:00 0.5 0.2 1.1 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 296 9 300 300 -3.2 0 -3 -3.3 12/23/2005 02:10:00 0.6 0.3 1.1 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 248 6 265 300 -3.1 0 -3 -3.3 12/23/2005 02:20:00 0.4 0.1 0.7 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 246 0 246 300 -3.1 0 -3 -3.3 12/23/2005 02:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 246 0 300 300 -3.1 0 -3 -3.3 12/23/2005 02:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.7 0.4 246 0 300 300 -3.2 0 -3 -3.3 12/23/2005 02:50:00 0.7 0.3 1.1 0.4 0.6 0.2 1.1 0.4 0.4 0.2 1.1 0.4 216 23 209 300 -3.2 0 -3.3 -3.3 12/23/2005 03:00:00 0.5 0.2 1.1 0.4 0.5 0.2 1.1 0.4 0.4 0.1 1.1 0.4 195 0 194 300 -3 0.1 -2.8 -3.3 12/23/2005 03:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0.1 1.1 0.4 195 0 300 300 -2.8 0 -2.6 -2.8 12/23/2005 03:20:00 0.6 0.3 1.1 0.4 0.5 0.2 1.1 0.4 0.5 0.2 1.1 0.4 121 51 89 300 -2.8 0 -2.6 -2.8 12/23/2005 03:30:00 0.7 0.2 1.1 0.4 0.6 0.2 1.1 0.4 0.4 0.1 0.7 0.4 76 0 77 300 -2.8 0 -2.6 -2.8 12/23/2005 03:40:00 1.2 0.6 2.6 0.4 1.2 0.7 2.6 0.4 0.9 0.5 1.9 0.4 68 7 60 300 -2.6 0 -2.6 -2.8 12/23/2005 03:50:00 2.6 0.3 3 2.3 2.6 0.3 3 2.3 2.2 0.3 3 1.5 57 4 59 300 -2.6 0 -2.6 -2.6 12/23/2005 04:00:00 3.1 0.2 3.4 2.6 3.1 0.2 3.4 2.6 2.7 0.2 3 2.3 52 2 52 300 -2.5 0.1 -2.1 -2.6 12/23/2005 04:10:00 3.3 0.2 3.8 2.6 3.3 0.2 3.8 2.6 2.5 0.3 3 1.5 49 2 50 300 -1.8 0 -1.7 -2.1 12/23/2005 04:20:00 1.5 1 3.4 0.4 1.5 1 3.4 0.4 0.8 0.6 2.6 0.4 59 20 45 300 -1.6 0 -1.4 -1.7 12/23/2005 04:30:00 0.9 0.5 1.9 0.4 0.9 0.5 1.9 0.4 0.5 0.3 1.5 0.4 88 21 103 300 -1.6 0 -1.4 -1.4 12/23/2005 04:40:00 1.5 0.4 2.6 0.7 1.4 0.4 2.6 0.4 0.5 0.2 1.5 0.4 82 8 77 300 -1.6 0 -1.4 -1.9 12/23/2005 04:50:00 1.8 0.3 2.6 1.1 1.8 0.4 2.6 0.7 1.1 0.5 1.9 0.4 82 8 86 300 -2 0 -1.9 -2.1 12/23/2005 05:00:00 1.8 0.3 2.6 1.1 1.8 0.3 2.6 1.1 1 0.2 1.5 0.4 61 6 62 300 -1.9 0 -1.9 -2.1 12/23/2005 05:10:00 1.1 0.6 1.9 0.4 1 0.6 1.9 0.4 0.4 0.2 1.1 0.4 66 7 56 300 -1.8 0 -1.7 -1.9 12/23/2005 05:20:00 0.4 0 0.7 0.4 0.4 0 0.7 0.4 0.6 0.4 1.9 0.4 85 41 209 300 -1.7 0 -1.4 -1.9 12/23/2005 05:30:00 1 0.3 1.5 0.4 0.8 0.3 1.1 0.4 1.3 0.2 1.5 0.7 222 9 214 300 -1.8 0 -1.7 -1.9 12/23/2005 05:40:00 1.3 0.2 1.9 0.7 1.1 0.2 1.5 0.7 1.5 0.2 1.9 1.1 244 9 251 300 -2 0 -1.9 -2.1 12/23/2005 05:50:00 1.3 0.2 1.9 0.7 1 0.3 1.5 0.7 1.2 0.3 1.9 0.7 267 1 261 300 -1.9 0 -1.9 -2.1 12/23/2005 06:00:00 1 0.2 1.5 0.4 0.7 0.3 1.1 0.4 1 0.2 1.5 0.4 268 0 268 300 -1.7 0 -1.7 -1.9 12/23/2005 06:10:00 0.9 0.2 1.1 0.4 0.5 0.2 1.1 0.4 0.9 0.2 1.5 0.4 268 0 268 300 -1.6 0 -1.4 -1.7 12/23/2005 06:20:00 0.8 0.4 1.5 0.4 0.6 0.4 1.5 0.4 0.6 0.3 1.1 0.4 273 7 270 300 -1.6 0 -1.4 -1.7 12/23/2005 06:30:00 0.8 0.3 1.5 0.4 0.5 0.3 1.5 0.4 0.5 0.2 1.1 0.4 294 1 291 300 -1.7 0 -1.4 -1.9 12/23/2005 06:40:00 0.5 0.2 0.7 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 293 1 295 300 -1.8 0 -1.9 -1.9 12/23/2005 06:50:00 0.9 0.4 1.9 0.4 0.6 0.4 1.5 0.4 0.6 0.4 1.5 0.4 277 13 259 300 -1.8 0 -1.7 -1.9 12/23/2005 07:00:00 1.5 0.3 1.9 0.7 1.3 0.3 1.9 0.7 0.7 0.4 1.5 0.4 253 4 257 300 -1.8 0 -1.7 -1.9 12/23/2005 07:10:00 1.2 0.5 2.3 0.4 1.1 0.5 2.3 0.4 1 0.6 1.9 0.4 224 27 189 300 -1.8 0 -1.7 -1.9 12/23/2005 07:20:00 1.7 0.4 2.6 0.4 1.9 0.4 2.6 0.4 1.8 0.4 2.3 0.4 192 10 183 300 -2 0 -1.9 -2.1 12/23/2005 07:30:00 1 0.4 1.9 0.4 1 0.4 1.9 0.4 0.7 0.3 1.5 0.4 211 13 227 300 -2.1 0 -1.9 -2.1 12/23/2005 07:40:00 1.2 0.4 2.3 0.4 0.9 0.5 1.9 0.4 0.8 0.4 1.5 0.4 233 3 233 300 -2.1 0 -1.9 -2.1 12/23/2005 07:50:00 1 0.4 1.9 0.4 0.8 0.4 1.5 0.4 0.4 0.2 1.1 0.4 252 9 257 300 -2.1 0 -1.9 -2.1 12/23/2005 08:00:00 0.9 0.6 1.9 0.4 0.8 0.5 1.9 0.4 0.6 0.3 1.9 0.4 224 12 229 300 -2.1 0 -1.9 -2.1 12/23/2005 08:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 222 0 300 300 -2 0 -1.9 -2.1 12/23/2005 08:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 222 0 300 300 -1.8 0 -1.9 -1.9 12/23/2005 08:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 222 0 300 300 -1.8 0 -1.9 -1.9 12/23/2005 08:40:00 0.4 0.2 1.1 0.4 0.4 0 0.4 0.4 0.4 0.2 1.1 0.4 207 13 194 300 -1.8 0 -1.9 -1.9 12/23/2005 08:50:00 0.4 0 0.7 0.4 0.4 0 0.4 0.4 0.4 0.1 0.7 0.4 194 0 194 300 -1.8 0 -1.9 -1.9 12/23/2005 09:00:00 0.4 0.1 0.7 0.4 0.4 0 0.4 0.4 0.4 0.1 0.7 0.4 194 0 193 300 -1.8 0 -1.9 -1.9 12/23/2005 09:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 194 0 300 300 -1.8 0 -1.7 -1.9 12/23/2005 09:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 194 0 300 300 -1.8 0 -1.7 -1.9 12/23/2005 09:30:00 0.4 0.1 0.7 0.4 0.4 0 0.4 0.4 0.4 0 0.7 0.4 194 0 193 300 -1.8 0 -1.9 -1.9 12/23/2005 09:40:00 0.4 0.1 0.7 0.4 0.4 0.1 1.1 0.4 0.4 0 0.4 0.4 194 0 194 300 -1.8 0 -1.7 -1.9 12/23/2005 09:50:00 0.4 0.1 0.7 0.4 0.4 0 0.7 0.4 0.4 0 0.4 0.4 194 0 194 300 -1.8 0 -1.7 -1.9 12/23/2005 10:00:00 0.4 0.1 0.7 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 197 2 194 300 -1.7 0 -1.7 -1.9 12/23/2005 10:10:00 0.6 0.2 1.1 0.4 0.4 0.1 1.1 0.4 0.5 0.2 0.7 0.4 280 24 299 300 -1.7 0 -1.4 -1.9 12/23/2005 10:20:00 0.9 0.3 1.5 0.4 0.6 0.3 1.1 0.4 0.4 0.2 1.1 0.4 268 9 261 300 -1.6 0 -1.4 -1.7 12/23/2005 10:30:00 1 0.4 1.5 0.4 0.8 0.4 1.5 0.4 0.8 0.4 1.5 0.4 263 3 263 300 -1.6 0 -1.4 -1.4 12/23/2005 10:40:00 1.3 0.4 2.3 0.4 1 0.4 1.9 0.4 0.8 0.4 1.5 0.4 264 8 249 300 -1.6 0 -1.4 -1.4 12/23/2005 10:50:00 1.2 0.2 1.5 0.7 1 0.3 1.5 0.4 0.8 0.2 1.5 0.4 278 8 264 300 -1.5 0 -1.4 -1.4 12/23/2005 11:00:00 0.9 0.2 1.5 0.4 0.7 0.2 1.1 0.4 0.6 0.2 1.1 0.4 296 5 291 300 -1.4 0 -1.2 -1.4 12/23/2005 11:10:00 1.7 0.4 2.3 1.1 1.5 0.4 2.3 0.7 1.4 0.3 1.9 0.7 284 6 289 300 -1.3 0 -1.2 -1.4 12/23/2005 11:20:00 1.4 0.6 2.3 0.4 1.1 0.5 1.9 0.4 0.8 0.4 1.9 0.4 269 24 265 300 -1 0 -1 -1.2 12/23/2005 11:30:00 0.6 0.3 1.5 0.4 0.5 0.2 1.1 0.4 0.4 0.1 1.1 0.4 278 15 305 300 -1 0 -0.7 -1 12/23/2005 11:40:00 1.1 0.3 1.9 0.4 0.8 0.4 1.5 0.4 0.6 0.2 1.1 0.4 267 2 265 300 -0.9 0 -0.7 -1 12/23/2005 11:50:00 0.4 0.1 1.1 0.4 0.4 0 0.7 0.4 0.4 0 0.4 0.4 266 0 267 300 -0.9 0 -0.7 -0.7 12/23/2005 12:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 265 0 300 300 -0.9 0 -0.7 -0.7 12/23/2005 12:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 265 0 300 300 -0.8 0 -0.7 -0.7 12/23/2005 12:20:00 0.4 0 0.7 0.4 0.4 0 0.4 0.4 0.4 0.1 0.7 0.4 265 0 266 300 -0.7 0 -0.5 -0.7 12/23/2005 12:30:00 0.4 0.1 0.7 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 134 72 267 300 -0.7 0 -0.5 -0.7 12/23/2005 12:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 93 0 300 300 -0.6 0 -0.5 -0.7 12/23/2005 12:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 93 0 300 300 -0.7 0 -0.5 -0.7 12/23/2005 13:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 93 0 300 300 -0.7 0 -0.5 -0.7 12/23/2005 13:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 93 0 300 300 -0.6 0 -0.5 -0.7 12/23/2005 13:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 93 0 300 300 -0.6 0 -0.5 -0.5 12/23/2005 13:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 93 0 300 300 -0.6 0 -0.5 -0.7 12/23/2005 13:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 93 0 300 300 -0.6 0 -0.5 -0.7 12/23/2005 13:50:00 0.4 0.1 0.7 0.4 0.4 0 0.4 0.4 0.4 0 0.7 0.4 77 13 93 300 -0.6 0 -0.5 -0.7 12/23/2005 14:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 65 0 300 300 -0.6 0 -0.5 -0.5 12/23/2005 14:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 65 0 300 300 -0.5 0 -0.5 -0.5 12/23/2005 14:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 65 0 300 300 -0.5 0 -0.3 -0.5 12/23/2005 14:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 65 0 300 300 -0.5 0 -0.3 -0.5 12/23/2005 14:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 65 0 300 300 -0.5 0 -0.5 -0.5 12/23/2005 14:50:00 0.4 0.1 0.7 0.4 0.4 0 0.4 0.4 0.5 0.2 1.1 0.4 166 47 188 300 -0.5 0 -0.5 -0.5 12/23/2005 15:00:00 0.4 0.1 1.1 0.4 0.4 0.1 1.1 0.4 0.4 0.2 1.1 0.4 188 3 187 300 -0.5 0 -0.5 -0.5 12/23/2005 15:10:00 0.5 0.2 1.1 0.4 0.4 0.1 1.1 0.4 0.6 0.3 1.1 0.4 204 0 203 300 -0.6 0 -0.5 -0.7 12/23/2005 15:20:00 0.4 0.2 1.1 0.4 0.4 0 0.4 0.4 0.5 0.2 1.1 0.4 204 0 204 300 -0.6 0 -0.5 -0.7 12/23/2005 15:30:00 0.4 0 0.7 0.4 0.4 0 0.4 0.4 0.4 0.1 0.7 0.4 204 0 204 300 -0.6 0 -0.5 -0.7 12/23/2005 15:40:00 0.4 0.1 1.1 0.4 0.4 0 0.4 0.4 0.4 0.1 1.1 0.4 207 1 204 300 -0.6 0 -0.5 -0.7 12/23/2005 15:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 207 0 300 300 -0.6 0 -0.5 -0.7 12/23/2005 16:00:00 0.8 0.4 1.5 0.4 0.7 0.4 1.5 0.4 0.9 0.4 1.5 0.4 192 9 187 300 -0.6 0 -0.5 -0.7 12/23/2005 16:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 205 10 300 300 -0.6 0 -0.5 -0.7 12/23/2005 16:20:00 0.5 0.2 1.1 0.4 0.4 0.1 1.1 0.4 0.4 0 0.4 0.4 228 23 259 300 -0.6 0 -0.5 -0.7 12/23/2005 16:30:00 0.4 0.1 1.1 0.4 0.4 0 0.4 0.4 0.5 0.3 1.1 0.4 201 36 178 300 -0.6 0 -0.5 -0.7 12/23/2005 16:40:00 0.4 0.1 0.7 0.4 0.4 0 0.7 0.4 0.4 0 0.4 0.4 177 0 177 300 -0.6 0 -0.5 -0.7 12/23/2005 16:50:00 0.8 0.3 1.1 0.4 0.6 0.3 1.1 0.4 0.7 0.3 1.1 0.4 177 0 177 300 -0.7 0 -0.5 -0.7 12/23/2005 17:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.7 0.4 177 0 300 300 -0.7 0 -0.5 -0.7 12/23/2005 17:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 177 0 300 300 -0.7 0 -0.5 -0.7 12/23/2005 17:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 177 0 300 300 -0.7 0 -0.5 -0.7 12/23/2005 17:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 177 0 300 300 -0.7 0 -0.5 -0.7 12/23/2005 17:40:00 0.4 0.1 0.7 0.4 0.4 0 0.4 0.4 0.5 0.2 1.1 0.4 347 39 354 300 -0.7 0 -0.5 -0.7 12/23/2005 17:50:00 0.6 0.3 1.1 0.4 0.5 0.2 1.1 0.4 0.8 0.2 1.1 0.4 20 0 20 300 -0.6 0 -0.5 -0.7 12/23/2005 18:00:00 1 0.5 1.9 0.4 0.8 0.4 1.9 0.4 1.1 0.2 1.5 0.7 20 1 20 300 -0.6 0 -0.5 -0.5 12/23/2005 18:10:00 2 0.4 3 1.1 2 0.5 2.6 0.7 1.6 0.4 2.3 0.7 34 7 37 300 -0.5 0 -0.5 -0.5 12/23/2005 18:20:00 1.4 0.6 2.3 0.4 1.3 0.6 2.3 0.4 0.9 0.5 2.3 0.4 59 17 52 300 -0.5 0 -0.5 -0.5 12/23/2005 18:30:00 1.2 0.5 2.3 0.4 1.1 0.5 2.3 0.4 1 0.4 2.3 0.4 74 5 67 300 -0.5 0 -0.5 -0.5 12/23/2005 18:40:00 1.5 0.3 2.3 0.7 1.5 0.3 2.3 0.7 1.1 0.5 2.3 0.4 66 3 70 300 -0.5 0 -0.5 -0.5 12/23/2005 18:50:00 0.9 0.5 1.9 0.4 0.8 0.5 1.9 0.4 0.8 0.4 1.5 0.4 75 13 93 300 -0.5 0 -0.5 -0.5 12/23/2005 19:00:00 0.7 0.5 1.9 0.4 0.7 0.5 1.9 0.4 0.7 0.5 1.9 0.4 79 7 78 300 -0.5 0 -0.5 -0.5 12/23/2005 19:10:00 0.5 0.2 1.1 0.4 0.4 0.2 1.1 0.4 0.4 0.1 1.1 0.4 68 2 65 300 -0.5 0 -0.3 -0.5 12/23/2005 19:20:00 0.6 0.3 1.1 0.4 0.5 0.2 1.1 0.4 0.5 0.2 1.1 0.4 68 3 69 300 -0.5 0 -0.3 -0.5 12/23/2005 19:30:00 1 0.3 1.5 0.4 0.9 0.4 1.5 0.4 0.8 0.3 1.5 0.4 54 5 55 300 -0.4 0 -0.3 -0.5 12/23/2005 19:40:00 1.4 0.3 1.9 0.7 1.3 0.3 1.9 0.4 1.1 0.3 1.5 0.4 45 9 56 300 -0.4 0 -0.3 -0.5 12/23/2005 19:50:00 1.5 0.4 2.3 0.4 1.3 0.4 2.3 0.4 1 0.3 1.5 0.4 36 7 33 300 -0.4 0 -0.3 -0.5 12/23/2005 20:00:00 1.7 0.3 2.6 0.7 1.6 0.3 2.3 0.7 1.2 0.4 2.3 0.4 48 5 52 300 -0.3 0 -0.3 -0.5 12/23/2005 20:10:00 1.6 0.2 2.3 1.1 1.6 0.2 1.9 1.1 1.2 0.4 1.9 0.4 45 6 50 300 -0.3 0 -0.1 -0.3 12/23/2005 20:20:00 1.7 0.2 2.3 1.1 1.6 0.2 2.3 1.1 1.4 0.2 1.9 0.7 54 5 53 300 -0.3 0 -0.1 -0.3 12/23/2005 20:30:00 1.8 0.3 2.3 1.1 1.8 0.4 2.6 0.7 1.4 0.3 2.3 0.7 52 6 70 300 -0.3 0 -0.1 -0.3 12/23/2005 20:40:00 1.1 0.3 1.9 0.4 1 0.3 1.5 0.4 0.8 0.2 1.5 0.4 57 6 56 300 -0.3 0 -0.1 -0.3 12/23/2005 20:50:00 0.9 0.5 1.9 0.4 0.8 0.4 1.9 0.4 0.6 0.3 1.5 0.4 45 13 39 300 -0.3 0 -0.1 -0.3 12/23/2005 21:00:00 0.4 0.1 0.7 0.4 0.4 0 0.7 0.4 0.4 0 0.4 0.4 44 9 57 300 -0.3 0 -0.3 -0.5 12/23/2005 21:10:00 0.4 0.1 0.7 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 57 0 57 300 -0.4 0 -0.3 -0.5 12/23/2005 21:20:00 0.6 0.3 1.5 0.4 0.5 0.2 1.1 0.4 0.4 0.1 1.1 0.4 92 24 112 300 -0.4 0 -0.3 -0.5 12/23/2005 21:30:00 0.4 0 0.7 0.4 0.4 0 0.7 0.4 0.4 0 0.4 0.4 112 0 112 300 -0.5 0 -0.3 -0.5 12/23/2005 21:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 112 0 300 300 -0.5 0 -0.5 -0.5 12/23/2005 21:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0.1 0.7 0.4 112 0 300 300 -0.3 0 -0.3 -0.5 12/23/2005 22:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.5 0.2 1.1 0.4 112 0 300 300 -0.3 0 -0.1 -0.5 12/23/2005 22:10:00 0.4 0 0.7 0.4 0.4 0 0.4 0.4 0.4 0.1 0.7 0.4 138 64 285 300 -0.3 0 -0.1 -0.3 12/23/2005 22:20:00 0.6 0.3 1.5 0.4 0.5 0.2 1.1 0.4 0.5 0.3 1.1 0.4 272 15 250 300 -0.2 0 -0.1 -0.3 12/23/2005 22:30:00 1.3 0.2 1.9 0.7 1 0.2 1.5 0.4 0.9 0.3 1.5 0.4 250 0 250 300 -0.4 0 -0.1 -0.5 12/23/2005 22:40:00 1.5 0.3 2.3 0.7 1.3 0.3 1.9 0.7 0.9 0.3 1.9 0.4 250 4 246 300 -0.4 0 -0.3 -0.5 12/23/2005 22:50:00 1.7 0.3 2.3 1.1 1.4 0.3 2.3 0.7 1.2 0.3 1.9 0.4 253 5 247 300 -0.5 0 -0.3 -0.5 12/23/2005 23:00:00 1.7 0.4 2.3 0.7 1.5 0.4 2.3 0.4 1.3 0.4 2.3 0.4 247 9 260 300 -0.5 0 -0.3 -0.5 12/23/2005 23:10:00 1.1 0.4 2.3 0.4 0.8 0.4 2.3 0.4 0.9 0.4 1.9 0.4 249 7 245 300 -0.3 0 -0.3 -0.5 12/23/2005 23:20:00 1.5 0.5 2.3 0.4 1.3 0.5 1.9 0.4 1 0.5 1.9 0.4 230 7 238 300 -0.3 0 -0.1 -0.3 12/23/2005 23:30:00 1.5 0.4 2.3 0.7 1.6 0.3 2.3 1.1 1.2 0.3 1.9 0.4 215 5 223 300 -0.4 0 -0.3 -0.5 12/23/2005 23:40:00 1.8 0.4 2.6 0.7 1.8 0.3 2.6 0.7 1.2 0.5 2.6 0.4 218 5 224 300 -0.5 0 -0.5 -0.5 12/23/2005 23:50:00 2.5 0.5 3.4 1.1 2.5 0.3 3.4 1.9 2.1 0.3 2.6 1.5 221 9 229 300 -0.6 0 -0.5 -0.7 12/24/2005 00:00:00 2.6 0.4 3.4 1.5 2.5 0.4 3.4 1.5 2 0.4 3 1.1 238 9 232 300 -0.6 0 -0.5 -0.7 12/24/2005 00:10:00 2 0.5 3 0.7 1.8 0.6 3 0.4 1.6 0.5 3 0.4 239 10 237 300 -0.6 0 -0.5 -0.7 12/24/2005 00:20:00 1.9 0.4 2.6 0.7 1.7 0.5 2.6 0.4 1.5 0.5 2.6 0.4 255 7 246 300 -0.6 0 -0.5 -0.7 12/24/2005 00:30:00 1.7 0.4 2.6 0.7 1.5 0.4 2.3 0.4 1.4 0.4 2.3 0.4 256 3 259 300 -0.5 0 -0.5 -0.7 12/24/2005 00:40:00 1.4 0.4 2.3 0.4 1.2 0.5 2.3 0.4 1 0.5 1.9 0.4 262 10 254 300 -0.5 0 -0.5 -0.5 12/24/2005 00:50:00 2.2 0.5 3 0.4 2 0.6 3 0.4 1.9 0.5 2.6 0.7 264 8 261 300 -0.5 0 -0.5 -0.5 12/24/2005 01:00:00 2.2 0.3 3 1.5 2 0.3 2.6 1.1 1.8 0.3 2.6 1.1 267 8 264 300 -0.4 0 -0.3 -0.5 12/24/2005 01:10:00 2.1 0.4 3 1.1 1.9 0.4 2.6 1.1 1.7 0.5 2.6 0.4 256 8 267 300 -0.3 0 -0.3 -0.5 12/24/2005 01:20:00 2 0.3 2.6 1.5 1.8 0.3 2.6 1.1 1.7 0.3 2.3 0.7 261 6 268 300 -0.4 0 -0.3 -0.5 12/24/2005 01:30:00 1.3 0.3 2.3 0.7 1 0.4 2.3 0.4 1 0.4 1.9 0.4 259 8 256 300 -0.5 0 -0.5 -0.5 12/24/2005 01:40:00 1.6 0.5 2.3 0.7 1.3 0.5 2.3 0.4 1.5 0.5 2.3 0.7 277 10 263 300 -0.5 0 -0.5 -0.5 12/24/2005 01:50:00 1.8 0.2 2.3 1.1 1.5 0.2 2.3 1.1 1.4 0.3 1.9 0.7 282 10 271 300 -0.6 0 -0.5 -0.7 12/24/2005 02:00:00 1.9 0.3 2.3 0.7 1.6 0.3 2.3 0.7 1.3 0.3 1.9 0.4 272 13 253 300 -0.6 0 -0.5 -0.7 12/24/2005 02:10:00 1.7 0.4 2.3 0.4 1.4 0.5 2.3 0.4 1.3 0.4 2.3 0.4 301 11 268 300 -0.7 0 -0.5 -0.7 12/24/2005 02:20:00 1.7 0.4 2.6 0.7 1.5 0.4 2.3 0.4 1.4 0.3 2.3 0.7 302 14 288 300 -0.7 0 -0.5 -0.7 12/24/2005 02:30:00 1.7 0.3 2.3 1.1 1.4 0.4 2.3 0.4 1.5 0.5 2.3 0.4 306 8 299 300 -0.6 0 -0.5 -0.7 12/24/2005 02:40:00 2 0.5 3 0.7 1.9 0.6 3 0.7 1.7 0.7 2.6 0.4 307 17 329 300 -0.6 0 -0.5 -0.7 12/24/2005 02:50:00 1.8 0.3 2.6 0.7 1.7 0.4 2.3 0.7 1.3 0.5 2.3 0.4 309 18 339 300 -0.6 0 -0.5 -0.7 12/24/2005 03:00:00 1.6 0.3 2.3 1.1 1.5 0.3 2.3 0.7 0.9 0.4 1.9 0.4 311 11 311 300 -0.6 0 -0.5 -0.7 12/24/2005 03:10:00 1.7 0.3 2.3 0.7 1.5 0.4 2.3 0.4 0.9 0.4 1.9 0.4 320 9 321 300 -0.6 0 -0.5 -0.7 12/24/2005 03:20:00 0.6 0.3 1.5 0.4 0.4 0.2 1.5 0.4 0.4 0 0.4 0.4 327 4 331 300 -0.7 0 -0.5 -0.7 12/24/2005 03:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0.1 0.7 0.4 326 0 300 300 -0.7 0 -0.5 -0.7 12/24/2005 03:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 326 0 300 300 -0.8 0 -0.5 -0.7 12/24/2005 03:50:00 0.4 0.1 0.7 0.4 0.4 0 0.4 0.4 0.5 0.2 1.1 0.4 31 64 326 300 -0.8 0 -0.7 -0.7 12/24/2005 04:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.5 0.2 1.1 0.4 93 0 300 300 -0.7 0 -0.3 -0.7 12/24/2005 04:10:00 0.4 0.1 1.1 0.4 0.4 0 0.4 0.4 0.5 0.2 1.1 0.4 94 0 94 300 -0.8 0 -0.7 -0.7 12/24/2005 04:20:00 0.4 0.1 0.7 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 93 0 94 300 -0.9 0 -0.7 -1 12/24/2005 04:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.7 0.4 93 0 300 300 -0.9 0 -0.7 -1 12/24/2005 04:40:00 0.4 0.2 1.5 0.4 0.4 0.2 1.1 0.4 0.5 0.3 1.5 0.4 68 33 3 300 -0.9 0 -0.7 -1 12/24/2005 04:50:00 0.7 0.2 1.1 0.4 0.4 0.2 1.1 0.4 0.8 0.3 1.5 0.4 3 0 4 300 -0.9 0 -0.7 -1 12/24/2005 05:00:00 0.4 0.1 0.7 0.4 0.4 0 0.4 0.4 0.4 0.2 1.1 0.4 3 0 4 300 -0.9 0 -0.7 -1 12/24/2005 05:10:00 0.4 0 0.7 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 3 0 4 300 -1 0 -0.7 -1 12/24/2005 05:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 3 0 300 300 -1 0 -0.7 -1 12/24/2005 05:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 3 0 300 300 -1 0 -1 -1 12/24/2005 05:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 3 0 300 300 -1 0 -1 -1.2 12/24/2005 05:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 3 0 300 300 -1 0 -1 -1.2 12/24/2005 06:00:00 0.4 0.1 1.1 0.4 0.4 0.1 0.7 0.4 0.4 0.2 1.1 0.4 8 11 34 300 -1.1 0 -1 -1.2 12/24/2005 06:10:00 1.3 0.6 2.3 0.4 1 0.7 2.3 0.4 1 0.4 1.9 0.4 30 5 25 300 -1.2 0 -1.2 -1.2 12/24/2005 06:20:00 2.5 0.2 3 1.9 2.4 0.2 3 1.9 1.8 0.4 2.6 0.7 37 6 37 300 -1.3 0 -1.2 -1.2 12/24/2005 06:30:00 2.3 0.3 3 1.9 2.3 0.3 3 1.5 1.8 0.3 2.6 1.1 52 6 49 300 -1.2 0 -1 -1.2 12/24/2005 06:40:00 2.4 0.2 3 1.5 2.4 0.3 3 1.1 1.6 0.3 2.3 0.7 39 4 38 300 -1.3 0 -1 -1.4 12/24/2005 06:50:00 2.7 0.3 3.4 1.9 2.6 0.3 3.4 1.5 1.6 0.3 2.6 0.7 37 3 35 300 -0.9 0 -0.7 -1 12/24/2005 07:00:00 2.5 0.5 3.4 1.1 2.3 0.5 3.4 0.7 1.5 0.5 2.6 0.4 38 4 41 300 -0.9 0 -0.7 -1 12/24/2005 07:10:00 2.2 0.4 3 1.1 1.9 0.4 3 1.1 1.1 0.3 1.9 0.4 27 6 30 300 -1 0 -0.7 -1 12/24/2005 07:20:00 0.8 0.8 3 0.4 0.7 0.7 2.6 0.4 0.9 0.4 1.9 0.4 289 117 28 300 -1.2 0.2 -1 -1.4 12/24/2005 07:30:00 0.9 0.6 2.3 0.4 0.9 0.6 2.3 0.4 1 0.5 2.3 0.4 74 39 51 300 -1.5 0 -1.2 -1.4 12/24/2005 07:40:00 2.2 0.4 3.4 1.1 2.2 0.5 3.4 1.1 1.7 0.2 2.3 1.1 55 22 42 300 -1.6 0 -1.4 -1.9 12/24/2005 07:50:00 1.4 0.6 3 0.4 1.3 0.6 2.6 0.4 1.1 0.4 2.3 0.4 135 9 127 300 -1.8 0 -1.7 -1.9 12/24/2005 08:00:00 1.5 0.6 2.6 0.4 1.5 0.6 2.6 0.4 1.2 0.6 2.3 0.4 80 29 52 300 -1.7 0 -1.4 -1.9 12/24/2005 08:10:00 2.3 0.3 3 1.5 2.3 0.3 3 1.1 1.8 0.4 2.6 0.7 44 7 41 300 -1.7 0 -1.4 -1.9 12/24/2005 08:20:00 1 0.6 2.6 0.4 0.9 0.6 2.6 0.4 0.8 0.4 2.3 0.4 52 8 53 300 -1.7 0 -1.4 -1.7 12/24/2005 08:30:00 1.5 0.6 2.6 0.4 1.3 0.6 2.6 0.4 1 0.5 2.3 0.4 28 3 26 300 -1.7 0 -1.4 -1.9 12/24/2005 08:40:00 2.6 0.3 3.4 1.5 2.3 0.4 3.4 1.1 1.6 0.4 2.3 0.7 29 7 34 300 -1.7 0 -1.7 -1.9 12/24/2005 08:50:00 2.4 0.4 3 1.1 2.3 0.5 3 0.7 1.5 0.4 2.3 0.4 45 12 40 300 -1.6 0 -1.4 -1.7 12/24/2005 09:00:00 2.2 0.4 3 1.1 2.2 0.4 3 1.5 1.5 0.3 2.3 1.1 59 8 53 300 -1.6 0 -1.4 -1.9 12/24/2005 09:10:00 1.4 0.7 3 0.4 1.4 0.7 3 0.4 1 0.5 1.9 0.4 75 26 50 300 -2 0.1 -1.7 -2.1 12/24/2005 09:20:00 0.8 0.4 1.5 0.4 0.7 0.4 1.5 0.4 0.7 0.4 1.5 0.4 80 18 101 300 -2 0 -1.9 -2.1 12/24/2005 09:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 68 0 300 300 -2.1 0 -2.1 -2.1 12/24/2005 09:40:00 0.4 0.1 1.1 0.4 0.4 0.1 1.1 0.4 0.4 0 0.4 0.4 68 0 68 300 -2.2 0 -2.1 -2.4 12/24/2005 09:50:00 0.5 0.3 1.5 0.4 0.5 0.2 1.1 0.4 0.5 0.3 1.1 0.4 47 35 67 300 -2.2 0 -2.1 -2.4 12/24/2005 10:00:00 0.4 0.1 0.7 0.4 0.4 0 0.4 0.4 0.5 0.3 1.1 0.4 294 18 287 300 -2.1 0 -2.1 -2.1 12/24/2005 10:10:00 1.4 0.5 2.6 0.4 1.3 0.6 2.6 0.4 0.7 0.4 1.9 0.4 41 20 50 300 -2.1 0 -1.9 -2.1 12/24/2005 10:20:00 1.9 0.6 3 0.7 1.8 0.6 3 0.7 0.8 0.4 1.9 0.4 47 7 44 300 -2.1 0 -1.9 -2.1 12/24/2005 10:30:00 2 0.6 3.4 1.1 2 0.6 3 0.7 0.9 0.3 1.5 0.4 52 8 44 300 -2.1 0 -2.1 -2.1 12/24/2005 10:40:00 2.3 0.4 3 1.5 2.1 0.5 3 0.7 1 0.3 1.9 0.4 35 7 47 300 -2.1 0 -2.1 -2.1 12/24/2005 10:50:00 1.6 0.4 3 0.4 1.5 0.5 3 0.4 0.7 0.3 1.5 0.4 42 8 36 300 -2.1 0 -2.1 -2.1 12/24/2005 11:00:00 2.5 0.8 3.8 0.4 2.4 0.9 3.8 0.4 1.5 0.7 3 0.4 47 9 47 300 -2.1 0 -2.1 -2.4 12/24/2005 11:10:00 3.6 0.3 4.2 3 3.6 0.3 4.6 3 2.7 0.2 3 2.3 47 6 41 300 -2.1 0 -1.9 -2.1 12/24/2005 11:20:00 4.3 0.4 5.3 3 3.9 0.5 4.9 2.3 2.6 0.5 3.8 1.5 34 4 41 300 -2 0 -1.7 -2.1 12/24/2005 11:30:00 4.2 0.5 5.7 3 3.7 0.6 5.7 2.3 2.7 0.5 5.3 1.5 30 8 24 300 -1.4 0.2 -0.7 -1.9 12/24/2005 11:40:00 4.7 0.7 6.5 2.6 4.4 0.8 6.1 2.3 3.1 0.8 4.9 1.1 37 10 36 300 -0.2 0.3 0.2 -0.7 12/24/2005 11:50:00 4.4 0.5 5.7 3.4 4.2 0.5 5.7 2.3 3.1 0.6 4.9 1.5 40 6 44 300 0.1 0 0.2 -0.1 12/24/2005 12:00:00 3.8 0.8 6.1 1.9 3.6 0.8 6.1 1.5 2.6 0.7 4.6 1.1 42 11 39 300 0.5 0.2 0.9 0.2 12/24/2005 12:10:00 1.5 0.8 4.2 0.4 1.5 0.8 4.2 0.4 1.5 0.6 4.2 0.4 95 28 70 300 0.2 0.7 1.1 -0.7 12/24/2005 12:20:00 2 0.5 3 1.1 1.9 0.5 3 0.7 2.1 0.5 3 0.7 131 26 166 300 -1.3 0.2 -0.7 -1.4 12/24/2005 12:30:00 0.7 0.4 1.9 0.4 0.6 0.4 1.9 0.4 0.7 0.4 1.5 0.4 67 4 85 300 -1.4 0 -1.2 -1.4 12/24/2005 12:40:00 0.6 0.3 1.5 0.4 0.6 0.3 1.5 0.4 0.6 0.4 1.5 0.4 156 32 174 300 -1.3 0 -1.2 -1.4 12/24/2005 12:50:00 0.4 0.2 1.5 0.4 0.4 0.2 1.9 0.4 0.4 0.1 0.7 0.4 86 6 67 300 -1.3 0 -1.2 -1.4 12/24/2005 13:00:00 1.7 0.5 2.6 0.4 1.6 0.6 2.6 0.4 1 0.4 1.9 0.4 37 14 52 300 -1.3 0 -1 -1.4 12/24/2005 13:10:00 2.4 0.3 3 1.5 2.3 0.3 3 1.1 1.3 0.4 2.3 0.4 44 8 32 300 -1 0 -0.7 -1.2 12/24/2005 13:20:00 2.8 0.5 4.2 1.9 2.8 0.4 4.2 1.9 1.5 0.3 2.6 0.7 50 7 35 300 -0.9 0 -0.7 -0.7 12/24/2005 13:30:00 4.4 0.5 5.7 3 4.3 0.6 5.7 3 2.7 0.5 4.2 1.5 44 4 45 300 -0.6 0.2 -0.1 -0.7 12/24/2005 13:40:00 2.5 1.1 4.9 0.4 2.4 1.2 5.3 0.4 1.7 0.7 3.8 0.4 101 56 42 300 -0.1 0.3 0.2 -0.7 12/24/2005 13:50:00 1.5 0.5 2.6 0.7 1.7 0.4 3 1.1 1.6 0.5 2.6 0.4 197 8 191 300 -1 0 -0.5 -1.2 12/24/2005 14:00:00 1.1 0.5 2.3 0.4 1.1 0.6 2.3 0.4 0.8 0.5 2.3 0.4 197 2 200 300 -1.2 0 -1 -1.2 12/24/2005 14:10:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 195 0 300 300 -1.2 0 -1.2 -1.2 12/24/2005 14:20:00 0.5 0.3 1.9 0.4 0.5 0.3 1.5 0.4 0.4 0.2 1.1 0.4 44 32 20 300 -1.1 0 -1 -1.2 12/24/2005 14:30:00 0.5 0.3 1.5 0.4 0.4 0.2 1.5 0.4 0.5 0.3 1.5 0.4 85 56 151 300 -1 0 -1 -1.2 12/24/2005 14:40:00 0.6 0.3 1.5 0.4 0.5 0.3 1.5 0.4 0.4 0.2 1.1 0.4 121 22 100 300 -1 0 -1 -1.2 12/24/2005 14:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.6 0.2 1.1 0.4 158 0 300 300 -1.2 0 -1.2 -1.2 12/24/2005 15:00:00 0.4 0.1 0.7 0.4 0.4 0.1 0.7 0.4 0.5 0.2 1.1 0.4 185 18 158 300 -1.4 0.1 -1.2 -1.4 12/24/2005 15:10:00 0.4 0.1 0.7 0.4 0.4 0.1 0.7 0.4 0.4 0.1 0.7 0.4 197 0 198 300 -1.6 0 -1.4 -1.4 12/24/2005 15:20:00 0.4 0.1 0.7 0.4 0.4 0 0.4 0.4 0.4 0.2 1.1 0.4 202 9 198 300 -1.6 0 -1.4 -1.7 12/24/2005 15:30:00 0.6 0.2 1.5 0.4 0.4 0.2 1.1 0.4 0.6 0.3 1.1 0.4 344 26 337 300 -1.7 0 -1.4 -1.9 12/24/2005 15:40:00 1.8 0.8 3.4 0.4 1.7 0.8 3.4 0.4 0.5 0.3 1.5 0.4 44 22 60 300 -2 0 -1.9 -2.1 12/24/2005 15:50:00 2.9 0.8 4.6 1.1 2.9 0.8 4.6 0.7 1.3 0.6 2.6 0.4 59 7 55 300 -2.2 0 -2.1 -2.6 12/24/2005 16:00:00 4.5 0.5 6.1 2.6 4.5 0.5 6.1 2.6 2.7 0.6 4.6 1.1 58 8 58 300 -2.1 0.2 -1.7 -2.6 12/24/2005 16:10:00 2.4 1.5 4.6 0.4 2.2 1.4 4.9 0.4 1.2 0.5 2.6 0.4 81 58 49 300 -2.4 0.3 -1.7 -2.8 12/24/2005 16:20:00 1.2 0.5 2.3 0.4 1.1 0.5 2.6 0.4 0.4 0.2 1.5 0.4 55 36 35 300 -2.7 0 -2.6 -2.8 12/24/2005 16:30:00 3.5 0.7 5.3 1.5 3.3 0.7 5.7 1.5 2.4 0.9 4.6 0.4 19 9 19 300 -2.6 0.1 -2.1 -2.8 12/24/2005 16:40:00 2.4 0.6 4.6 1.5 2.3 0.5 4.2 1.1 1.5 0.5 2.6 0.4 40 10 29 300 -2 0.3 -1.4 -2.6 12/24/2005 16:50:00 2.2 0.5 3.8 1.1 2.1 0.6 3.8 0.7 1.4 0.6 2.6 0.4 50 17 37 300 -2.6 0 -2.4 -2.6 12/24/2005 17:00:00 3.1 0.6 4.6 1.5 3.1 0.6 4.9 1.5 2.2 0.7 3.8 0.4 47 8 71 300 -2 0.3 -1.4 -2.6 12/24/2005 17:10:00 1.2 0.8 3.8 0.4 1.2 0.9 3.4 0.4 1 0.6 2.6 0.4 68 26 77 300 -2 0.4 -1.4 -2.6 12/24/2005 17:20:00 1 0.8 2.6 0.4 1 0.8 2.6 0.4 1.3 0.9 3 0.4 122 58 180 300 -2.8 0.3 -2.4 -3.3 12/24/2005 17:30:00 0.4 0.1 1.1 0.4 0.4 0.1 1.1 0.4 0.5 0.2 1.1 0.4 123 33 145 300 -3.5 0.1 -3.3 -3.7 12/24/2005 17:40:00 1 0.6 2.3 0.4 0.9 0.6 2.3 0.4 1 0.5 2.3 0.4 158 17 187 300 -3.8 0 -3.5 -3.9 12/24/2005 17:50:00 0.8 0.5 1.9 0.4 0.7 0.5 1.9 0.4 1 0.6 1.9 0.4 193 13 195 300 -4.1 0.1 -3.9 -4.4 12/24/2005 18:00:00 0.4 0.1 0.7 0.4 0.4 0 0.4 0.4 0.4 0.1 1.1 0.4 170 0 169 300 -4 0 -3.7 -4.4 12/24/2005 18:10:00 0.8 0.4 1.5 0.4 0.6 0.4 1.5 0.4 0.4 0.1 0.7 0.4 156 15 154 300 -3.8 0 -3.7 -3.9 12/24/2005 18:20:00 0.5 0.2 1.1 0.4 0.4 0.2 1.1 0.4 0.5 0.2 1.1 0.4 153 33 131 300 -3.9 0.1 -3.7 -4.2 12/24/2005 18:30:00 0.5 0.2 1.1 0.4 0.4 0.2 1.1 0.4 0.6 0.3 1.1 0.4 215 0 216 300 -3.8 0 -3.5 -3.9 12/24/2005 18:40:00 1.1 0.6 2.3 0.4 1.1 0.5 2.3 0.4 1.1 0.4 1.9 0.4 201 15 189 300 -3.7 0 -3.5 -3.7 12/24/2005 18:50:00 1.3 0.3 1.9 0.7 1.2 0.3 1.9 0.7 1.3 0.2 1.9 0.7 211 22 191 300 -3.7 0 -3.5 -3.9 12/24/2005 19:00:00 0.7 0.4 1.5 0.4 0.6 0.3 1.1 0.4 1 0.2 1.5 0.4 253 3 245 300 -3.5 0.2 -3 -3.9 12/24/2005 19:10:00 0.4 0.1 0.7 0.4 0.4 0 0.7 0.4 0.7 0.3 1.5 0.4 242 18 230 300 -3.2 0 -2.8 -3.5 12/24/2005 19:20:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 1 0.3 1.9 0.4 254 38 300 300 -2.9 0 -2.8 -3 12/24/2005 19:30:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0.1 0.7 0.4 299 0 300 300 -3.2 0 -3 -3.3 12/24/2005 19:40:00 0.5 0.2 1.1 0.4 0.4 0.2 1.1 0.4 0.6 0.3 1.5 0.4 340 19 329 300 -3 0.1 -2.6 -3.3 12/24/2005 19:50:00 0.4 0.1 0.7 0.4 0.4 0 0.4 0.4 0.5 0.3 1.5 0.4 0 0 0 300 -2.6 0.1 -2.4 -2.8 12/24/2005 20:00:00 1.1 0.6 1.9 0.4 1 0.5 1.9 0.4 1.4 0.2 1.9 0.7 255 64 221 300 -2.6 0 -2.6 -2.8 12/24/2005 20:10:00 2.1 0.2 2.6 1.5 2 0.2 2.3 1.5 1.7 0.2 2.3 1.1 245 8 234 300 -2.8 0 -2.6 -2.8 12/24/2005 20:20:00 2.4 0.3 3 1.9 2.2 0.2 2.6 1.5 1.9 0.4 2.6 0.4 249 3 251 300 -2.6 0.1 -2.1 -2.8 12/24/2005 20:30:00 1.8 0.5 3 0.7 1.7 0.4 2.6 0.7 1.4 0.4 2.3 0.4 237 17 258 300 -2.1 0 -1.9 -2.6 12/24/2005 20:40:00 1.8 0.6 3 0.4 1.7 0.5 3 0.4 1.5 0.4 2.3 0.4 214 17 222 300 -2.8 0 -2.4 -3 12/24/2005 20:50:00 1.3 0.7 3 0.4 1.2 0.7 2.6 0.4 0.8 0.5 2.3 0.4 243 18 226 300 -2.8 0 -2.6 -2.8 12/24/2005 21:00:00 1.7 0.7 3 0.4 1.5 0.7 2.6 0.4 1.3 0.6 3 0.4 257 38 220 300 -2.8 0 -2.6 -3 12/24/2005 21:10:00 0.8 0.5 1.9 0.4 0.7 0.5 1.9 0.4 0.6 0.3 1.9 0.4 217 29 219 300 -2.5 0 -2.4 -2.6 12/24/2005 21:20:00 1.9 0.4 2.6 0.4 1.7 0.4 2.6 0.4 1.3 0.5 2.3 0.4 240 10 235 300 -2.6 0 -2.6 -2.6 12/24/2005 21:30:00 1.1 0.5 2.3 0.4 1 0.5 1.9 0.4 0.8 0.4 1.9 0.4 225 4 227 300 -2.4 0 -2.1 -2.6 12/24/2005 21:40:00 1 0.4 1.9 0.4 0.8 0.4 1.9 0.4 0.5 0.3 1.5 0.4 220 11 225 300 -2.5 0 -2.4 -2.6 12/24/2005 21:50:00 0.5 0.3 1.5 0.4 0.4 0.3 1.9 0.4 0.4 0.1 0.7 0.4 157 79 64 300 -2.6 0 -2.4 -2.6 12/24/2005 22:00:00 1 0.6 2.6 0.4 0.9 0.5 2.6 0.4 0.9 0.6 1.9 0.4 126 45 85 300 -2.4 0 -2.1 -2.6 12/24/2005 22:10:00 2 0.5 3 0.7 1.9 0.4 3 0.4 1.6 0.4 2.3 0.7 179 11 189 300 -2.2 0 -2.1 -2.6 12/24/2005 22:20:00 1 0.6 3 0.4 0.9 0.7 3 0.4 0.7 0.6 2.6 0.4 188 20 220 300 -2.1 0 -1.9 -2.1 12/24/2005 22:30:00 0.7 0.3 1.5 0.4 0.5 0.3 1.5 0.4 0.5 0.2 1.1 0.4 162 17 146 300 -2.1 0 -2.1 -2.1 12/24/2005 22:40:00 0.7 0.5 2.3 0.4 0.6 0.5 2.3 0.4 0.6 0.4 1.9 0.4 141 94 196 300 -2.1 0 -2.1 -2.1 12/24/2005 22:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.4 0 0.4 0.4 226 11 300 300 -2.2 0 -2.1 -2.4 12/24/2005 23:00:00 0.5 0.3 1.5 0.4 0.4 0.2 1.1 0.4 0.5 0.3 1.5 0.4 232 41 217 300 -2.2 0 -2.1 -2.4 12/24/2005 23:10:00 0.5 0.2 1.5 0.4 0.4 0.2 1.1 0.4 0.5 0.3 1.5 0.4 78 61 357 300 -2.4 0 -2.1 -2.4 12/24/2005 23:20:00 0.5 0.3 1.5 0.4 0.4 0.2 1.5 0.4 0.5 0.2 1.1 0.4 119 26 89 300 -2.4 0 -2.4 -2.6 12/24/2005 23:30:00 1.5 0.4 2.6 0.4 1.4 0.5 2.6 0.4 1.5 0.3 2.3 0.7 89 15 94 300 -2.5 0 -2.4 -2.6 12/24/2005 23:40:00 0.9 0.4 1.9 0.4 0.7 0.4 1.5 0.4 1 0.3 1.9 0.4 108 32 146 300 -2.2 0 -2.1 -2.6 12/24/2005 23:50:00 1.6 0.3 2.6 1.1 1.5 0.3 2.6 1.1 1.2 0.3 1.9 0.4 75 9 80 300 -2 0 -1.9 -2.1 12/25/2005 00:00:00 1.3 0.4 2.3 0.4 1.2 0.5 2.3 0.4 0.9 0.5 1.5 0.4 82 10 91 300 -2 0 -1.9 -2.1 12/25/2005 00:10:00 2.1 0.7 3.4 0.7 2.2 0.7 3.4 0.7 1.1 0.5 2.3 0.4 74 10 75 300 -2.1 0 -1.9 -2.1 12/25/2005 00:20:00 1.3 0.8 2.6 0.4 1.2 0.8 2.6 0.4 0.7 0.4 1.9 0.4 86 47 65 300 -2.1 0 -1.9 -2.1 12/25/2005 00:30:00 0.6 0.4 1.9 0.4 0.6 0.4 1.9 0.4 0.4 0.2 1.1 0.4 120 41 85 300 -2.2 0 -2.1 -2.4 12/25/2005 00:40:00 1.1 0.5 2.3 0.4 1.1 0.5 1.9 0.4 1 0.6 2.3 0.4 169 39 216 300 -2.2 0 -2.1 -2.4 12/25/2005 00:50:00 0.8 0.4 1.5 0.4 0.7 0.3 1.5 0.4 0.4 0.2 1.1 0.4 174 5 166 300 -2.1 0 -2.1 -2.1 12/25/2005 01:00:00 0.6 0.4 1.5 0.4 0.5 0.3 1.5 0.4 0.5 0.2 1.1 0.4 178 17 176 300 -2 0 -1.9 -2.1 12/25/2005 01:10:00 1 0.3 1.5 0.4 0.8 0.4 1.5 0.4 0.7 0.3 1.5 0.4 201 22 200 300 -2.1 0 -1.9 -2.1 12/25/2005 01:20:00 0.8 0.4 1.5 0.4 0.8 0.3 1.5 0.4 0.6 0.3 1.5 0.4 203 13 183 300 -2.4 0 -2.1 -2.6 12/25/2005 01:30:00 0.4 0.2 1.1 0.4 0.4 0.2 1.1 0.4 0.6 0.3 1.1 0.4 266 58 227 300 -2.2 0 -2.1 -2.6 12/25/2005 01:40:00 0.4 0.2 1.1 0.4 0.4 0.1 0.7 0.4 0.7 0.3 1.5 0.4 336 4 345 300 -2.1 0 -1.9 -2.4 12/25/2005 01:50:00 1.4 0.8 3 0.4 1.2 0.7 2.6 0.4 1.1 0.6 2.3 0.4 7 26 33 300 -1.8 0 -1.4 -2.1 12/25/2005 02:00:00 1.8 1.1 4.6 0.4 1.6 1.1 4.6 0.4 1 0.7 3.4 0.4 39 15 43 300 -2.1 0 -1.9 -2.1 12/25/2005 02:10:00 3.7 1.2 6.1 0.4 3.6 1.3 6.1 0.4 2 1.1 4.9 0.4 42 11 43 300 -2.1 0 -1.9 -2.4 12/25/2005 02:20:00 4.5 0.8 6.5 2.6 4.4 0.8 6.5 2.6 2.3 0.9 4.2 0.4 47 9 40 300 -2 0.2 -1.4 -2.4 12/25/2005 02:30:00 3.9 0.5 5.3 2.6 3.8 0.5 5.3 2.6 2.4 0.6 3.8 1.1 43 9 36 300 -1 0.2 -0.7 -1.4 12/25/2005 02:40:00 4.9 0.8 7.2 3 4.5 0.8 7.2 2.6 3.2 0.7 6.1 1.5 33 9 40 300 0 0.3 0.7 -0.7 12/25/2005 02:50:00 5.2 1 7.6 2.3 4.8 1.1 7.6 1.9 3.4 1.2 6.5 0.4 37 11 38 300 0.9 0.1 1.4 0.4 12/25/2005 03:00:00 5.3 1.1 8 3 4.8 1.1 7.6 2.3 3.3 1.1 7.2 0.7 39 15 32 300 1.4 0.1 1.8 0.9 12/25/2005 03:10:00 6.5 1 9.9 3.8 5.9 1.1 9.1 3 4.5 1.1 8 1.9 38 12 35 300 2.6 0.4 3 1.8 12/25/2005 03:20:00 6.5 1 9.1 3.8 6 1.1 8.8 2.6 4.5 1.2 7.6 1.1 38 12 45 300 3.3 0.2 3.5 2.8 12/25/2005 03:30:00 6.7 0.9 8.4 3.8 6.3 1 8.4 3.8 5 1 8 2.6 38 9 46 300 3.6 0 3.8 3.5 12/25/2005 03:40:00 7 1.3 9.5 3.4 6.7 1.3 8.8 3 5.3 1.2 8.4 2.6 44 11 25 300 3.8 0 3.8 3.8 12/25/2005 03:50:00 5.9 1 8.8 3.4 5.9 1 8.8 3.4 5 1.1 8.4 1.9 59 11 48 300 3.9 0 4 3.8 12/25/2005 04:00:00 7.1 1.2 10.3 4.2 7 1.2 10.3 4.2 5.7 1.3 8.8 2.6 46 10 49 300 4 0 4.3 4 12/25/2005 04:10:00 6.4 1 8.8 3.8 6.1 1 8.8 3.8 4.8 1 7.2 2.3 43 13 32 300 4.3 0 4.5 4 12/25/2005 04:20:00 6.5 1.3 9.5 3.4 5.8 1.2 9.1 2.6 4.6 1 7.2 2.3 33 11 36 300 4.1 0 4.3 4 12/25/2005 04:30:00 5.7 1 9.5 3 5.1 1.1 8.8 2.6 4.3 1 8.4 1.9 30 13 36 300 4 0 4 3.8 12/25/2005 04:40:00 6.5 0.9 8.4 3.8 5.8 1 8.4 3 4.8 0.9 7.2 2.3 31 11 27 300 4 0 4.3 3.8 12/25/2005 04:50:00 6.1 1 9.1 3.8 5.6 1 8.8 3 4.5 1.1 7.6 2.3 36 10 18 300 4.1 0 4.3 4 12/25/2005 05:00:00 6.4 1 8.8 3 5.7 1 8.8 3 4.6 1.1 8.4 1.9 33 10 44 300 4.3 0 4.5 4 12/25/2005 05:10:00 6.1 1.3 8.8 2.6 5.5 1.3 8.8 2.3 4.6 1.2 8 1.1 26 13 17 300 4.3 0.1 4.5 4 12/25/2005 05:20:00 6.7 1.1 9.1 3.4 5.9 1 8.4 3 4.7 0.9 7.2 2.6 27 11 25 300 4 0 4.3 4 12/25/2005 05:30:00 5.7 1.2 8.8 3 5.2 1.1 8.8 3 4.3 1.1 8 1.9 27 13 33 300 3.9 0 4 3.8 12/25/2005 05:40:00 4.7 0.8 6.8 2.6 4.3 0.9 7.2 2.3 3.5 0.8 5.7 1.5 34 11 38 300 3.8 0 4 3.8 12/25/2005 05:50:00 4.3 0.8 7.2 1.9 3.9 0.8 6.5 1.9 2.9 0.8 5.7 1.1 32 13 21 300 3.6 0 3.8 3.5 12/25/2005 06:00:00 5.3 1 8 3 4.8 1 7.6 2.3 4 1 6.1 1.9 33 13 25 300 3.9 0.1 4.3 3.8 12/25/2005 06:10:00 6.3 1.1 9.1 3.4 5.5 1 8 3 4.5 1 7.6 2.3 28 10 19 300 4 0 4.3 4 12/25/2005 06:20:00 6.2 1.1 9.1 3.4 5.4 1.1 8 2.6 4.5 1 7.2 1.9 26 11 31 300 4 0 4 3.8 12/25/2005 06:30:00 6.6 1 9.1 4.2 5.7 1 8.4 3 4.6 1 8 2.3 27 11 17 300 4 0 4 3.8 12/25/2005 06:40:00 6.9 1.1 9.5 3.4 6 1.1 8.8 3 5 1 7.6 2.3 23 10 30 300 3.8 0 4 3.8 12/25/2005 06:50:00 7 0.9 9.1 4.2 6 0.9 9.1 3.4 5 1 8.4 2.6 22 9 20 300 3.7 0 3.8 3.5 12/25/2005 07:00:00 6.2 1 9.1 3 5.5 0.9 8.4 2.6 4.4 1 6.8 1.1 21 9 29 300 3.6 0 3.8 3.5 12/25/2005 07:10:00 6.6 1.3 9.1 2.6 5.7 1.3 9.1 2.3 4.6 1.2 8.4 1.9 27 13 19 300 3.5 0 3.8 3.5 12/25/2005 07:20:00 7.1 1.2 9.9 3.8 6.2 1.2 9.9 3.4 5 1.1 8 1.9 29 13 36 300 3.8 0 4.3 3.5 12/25/2005 07:30:00 6.6 1 9.1 3.8 5.9 1 8.8 3 5 1 8.8 2.3 23 10 30 300 3.9 0 4 3.8 12/25/2005 07:40:00 6.1 1.3 8.8 2.6 5.3 1.2 8.8 1.9 4.5 1.1 8 1.9 29 12 9 300 3.6 0 3.8 3.5 12/25/2005 07:50:00 5.2 0.9 8 2.3 5.1 1 7.2 1.9 4.3 1 7.6 1.9 49 15 41 300 3.6 0 3.8 3.5 12/25/2005 08:00:00 5.4 1.2 8.8 2.3 4.9 1.2 8.4 2.3 4 1 7.6 1.1 30 18 25 300 3.5 0 3.8 3.3 12/25/2005 08:10:00 3.7 1 6.5 1.5 3.4 1 6.1 1.1 2.8 0.9 5.7 0.7 34 20 11 300 3.1 0.1 3.5 2.8 12/25/2005 08:20:00 3.7 1 6.8 1.1 3.6 1 6.5 0.7 3.1 1 6.1 0.7 45 26 359 300 2.9 0 2.8 2.8 12/25/2005 08:30:00 5.1 1.3 8.4 1.1 5.1 1.3 8.4 1.5 4.2 1.4 7.6 1.1 52 16 43 300 2.8 0 2.8 2.6 12/25/2005 08:40:00 6.9 1 9.9 4.6 6.2 1 9.5 3.8 5.1 0.9 8 3 33 11 31 300 2.8 0 3 2.6 12/25/2005 08:50:00 6.7 1 9.5 3.8 6.1 1 9.1 3.4 5.1 1 8.8 2.6 34 9 35 300 2.9 0 2.8 2.8 12/25/2005 09:00:00 4.9 1 8.4 1.9 4.8 1.1 8.4 1.9 4.3 1.1 7.2 1.9 47 16 38 300 2.9 0 3 2.8 12/25/2005 09:10:00 4.7 1.1 7.6 1.5 4.4 1.2 7.6 1.1 3.7 1.2 7.6 1.1 38 17 54 300 2.8 0 2.8 2.8 12/25/2005 09:20:00 5.3 1.3 9.5 2.3 5 1.3 9.5 2.3 3.9 1.3 8.4 1.1 36 17 40 300 2.9 0 2.8 2.8 12/25/2005 09:30:00 7.2 1.1 9.5 4.2 6.4 1.1 9.1 3.8 5.4 1 8.8 2.6 30 9 31 300 2.7 0 2.8 2.8 12/25/2005 09:40:00 6.7 1.2 9.5 3.8 6.1 1.2 9.1 3.4 5.3 1 8.4 3 31 13 28 300 2.7 0 2.8 2.6 12/25/2005 09:50:00 6.9 1.2 9.1 3.8 6.2 1.2 9.5 3 5.1 1.3 8.4 1.9 30 13 45 300 2.8 0 2.8 2.8 12/25/2005 10:00:00 6.3 1.5 9.9 3 5.7 1.3 8.8 2.3 4.7 1.3 8.4 1.9 33 14 22 300 2.9 0 2.8 2.8 12/25/2005 10:10:00 6.3 1.2 9.5 3.4 5.7 1.1 8.8 2.6 4.5 1 7.2 1.9 33 13 13 300 2.8 0 2.8 2.8 12/25/2005 10:20:00 6.7 1.2 9.9 3.4 5.9 1.1 8.4 3 4.8 1.1 7.6 1.9 26 12 26 300 2.8 0 2.8 2.6 12/25/2005 10:30:00 6.3 1.1 9.1 3.4 5.4 1 8 3 4.5 1 7.6 1.5 28 12 32 300 2.7 0 2.8 2.6 12/25/2005 10:40:00 5.2 1.5 8.4 0.7 4.6 1.3 8 1.5 3.6 1.2 7.2 0.7 34 17 31 300 2.7 0 2.8 2.6 12/25/2005 10:50:00 3.2 1.5 6.8 0.4 3.1 1.3 6.5 0.4 2.4 0.9 5.3 0.7 52 28 27 300 1.6 0.7 2.8 0.7 12/25/2005 11:00:00 5.1 1 8 2.3 4.6 1 7.6 1.9 3.3 1 6.5 1.1 35 14 25 300 2.1 0.1 2.3 1.6 12/25/2005 11:10:00 6.5 1.5 10.7 2.6 5.9 1.3 9.5 2.6 4.7 1.2 7.6 1.5 31 15 24 300 2.6 0 2.8 2.3 12/25/2005 11:20:00 5.2 1.3 9.1 2.6 4.8 1.2 8.8 2.3 3.8 1.1 8 1.5 36 17 62 300 2.6 0 2.8 2.3 12/25/2005 11:30:00 5.8 1.2 8.4 3 5.3 1.2 8.4 2.6 4.2 1.2 7.2 1.1 36 15 43 300 2.3 0 2.6 2.3 12/25/2005 11:40:00 6.4 1.1 10.3 3.4 5.9 1.1 9.9 3 4.8 1.1 8.4 2.3 34 12 36 300 2.3 0 2.6 2.3 12/25/2005 11:50:00 6.2 1 8.8 3.8 5.6 1.1 8.8 3 4.8 1 8.4 2.6 31 12 27 300 2.4 0 2.6 2.3 12/25/2005 12:00:00 6.1 1 9.1 4.2 5.4 1 8.4 3 4.7 1 7.6 1.9 27 11 28 300 2.4 0 2.6 2.3 12/25/2005 12:10:00 5.2 1.3 9.1 1.9 4.7 1.2 8.4 1.9 3.9 1.2 8 0.7 26 15 16 300 2.4 0 2.6 2.3 12/25/2005 12:20:00 4.2 1.2 7.6 1.5 4.1 1.2 7.6 1.1 3.7 1.1 6.5 1.1 50 22 33 300 2.5 0 2.6 2.6 12/25/2005 12:30:00 4.5 1.5 7.6 1.1 4.2 1.4 7.2 1.5 3.5 1.2 6.8 0.4 41 22 10 300 2.5 0 2.8 2.3 12/25/2005 12:40:00 7.2 1 9.5 3.8 6.3 1.1 9.1 3.4 5.1 1.1 8 2.3 27 11 20 300 2.8 0 2.8 2.6 12/25/2005 12:50:00 6.9 1.3 10.3 3.4 6.4 1.3 10.7 2.3 5.1 1.2 8.4 2.3 36 12 35 300 2.9 0 2.8 2.8 12/25/2005 13:00:00 5.1 1.7 8.8 0.7 4.7 1.7 8.8 1.1 3.6 1.5 6.8 0.4 42 28 30 300 2.8 0 2.8 2.6 12/25/2005 13:10:00 2.5 1.4 6.5 0.4 2.4 1.3 6.5 0.4 1.9 1 4.9 0.4 52 56 36 300 2.4 0.3 2.8 1.4 12/25/2005 13:20:00 4.2 1.5 7.2 0.7 3.9 1.3 6.8 0.7 3 1.3 6.5 0.4 28 21 30 300 1.6 0.4 2.3 0.9 12/25/2005 13:30:00 3.7 1.3 7.6 1.1 3.5 1.2 7.2 1.1 2.4 1 6.1 0.4 42 30 7 300 2 0.2 2.3 1.6 12/25/2005 13:40:00 4.1 1.3 7.2 1.1 4 1.2 6.8 0.7 3.2 1.1 6.1 0.7 44 19 45 300 1.7 0.3 2.3 1.4 12/25/2005 13:50:00 3.2 1.3 7.2 0.4 3.1 1.2 7.6 0.4 2.5 1 6.5 0.4 46 29 33 300 2 0.1 2.3 1.4 12/25/2005 14:00:00 2.9 1 5.7 0.7 2.9 1 5.3 0.4 2.3 1.2 5.7 0.4 43 24 54 300 0.9 0.3 1.8 0.7 12/25/2005 14:10:00 3.8 1.5 7.2 0.7 3.5 1.3 6.8 0.4 2.9 1.2 6.5 0.4 59 41 37 300 1.4 0.7 2.1 -0.1 12/25/2005 14:20:00 4 1.1 7.2 1.5 3.8 1.1 6.8 1.1 2.7 1 6.5 0.4 35 21 20 300 0.4 0.6 1.6 -0.3 12/25/2005 14:30:00 5 1.3 8.4 1.9 4.5 1.2 7.6 1.9 3.6 1.1 6.5 0.7 30 17 38 300 1.8 0 1.8 1.6 12/25/2005 14:40:00 5.2 1.1 7.6 2.3 4.8 1.1 7.6 1.9 4.1 0.9 6.5 1.9 24 16 31 300 2 0 2.1 1.8 12/25/2005 14:50:00 5.6 1 7.6 3.4 5.1 1.1 8 2.6 4.4 1.1 7.6 1.1 23 14 15 300 2.1 0 2.3 1.8 12/25/2005 15:00:00 6.2 1.1 9.1 3 5.6 1.1 9.5 3 4.7 1.2 8.4 2.3 25 13 54 300 2 0 2.1 1.8 12/25/2005 15:10:00 6.7 1 9.1 3.4 6.2 1.1 9.5 3.4 5.1 1.2 8 1.5 17 11 36 300 2.1 0 2.3 1.8 12/25/2005 15:20:00 6.7 1.1 9.5 3.8 6 1.1 8.8 3 5 1.2 9.1 2.3 20 12 18 300 2 0 2.3 1.8 12/25/2005 15:30:00 6.5 1.1 8.8 4.2 5.7 1.1 8.8 3.4 4.5 1.3 8.4 1.1 24 12 22 300 2 0 2.1 1.8 12/25/2005 15:40:00 6.7 1.1 9.5 3.8 6 1.1 9.9 3.4 5 1 7.6 2.3 28 12 16 300 1.9 0 2.1 1.8 12/25/2005 15:50:00 7.3 1.3 10.3 3.4 6.6 1.3 10.7 3 5.5 1.2 9.5 3 21 11 28 300 2.1 0 2.3 1.8 12/25/2005 16:00:00 8 1.3 10.7 3.8 7.2 1.4 10.7 3.8 6.1 1.3 9.5 3 23 10 30 300 2.2 0 2.3 2.1 12/25/2005 16:10:00 8 1.3 10.7 4.9 7.3 1.3 10.7 4.6 6.3 1.3 9.9 3 20 11 12 300 2.1 0 2.3 1.8 12/25/2005 16:20:00 7.8 1.3 11.5 4.6 7 1.3 10.7 3.8 6 1.2 9.1 3 23 13 25 300 2.1 0 2.3 2.1 12/25/2005 16:30:00 6.9 1.3 10.3 3.8 6.1 1.3 9.1 3 5.1 1.2 9.1 2.3 24 11 34 300 2.3 0 2.6 2.3 12/25/2005 16:40:00 7.6 1.3 11.5 4.9 6.8 1.3 10.3 3.8 5.8 1.5 10.3 2.6 25 12 33 300 2.4 0 2.6 2.3 12/25/2005 16:50:00 7.8 1.2 10.7 4.2 6.9 1.3 10.7 3.4 5.7 1.2 8.8 1.5 25 13 34 300 2.5 0 2.6 2.6 12/25/2005 17:00:00 8 1.1 10.7 4.9 7.2 1.1 9.9 4.6 6.1 1.2 9.1 3.4 30 12 28 300 2.5 0 2.8 2.6 12/25/2005 17:10:00 7.6 1.4 10.7 3.4 7 1.3 11.1 3 6.1 1.3 10.7 2.6 34 14 33 300 2.4 0 2.6 2.3 12/25/2005 17:20:00 7.1 1.3 10.7 3.8 6.6 1.3 10.3 3.4 5.6 1.3 10.3 2.6 34 13 30 300 2.3 0 2.6 2.3 12/25/2005 17:30:00 7.1 1.3 10.7 3.8 6.6 1.3 9.9 2.6 5.7 1.2 8.8 2.6 36 14 32 300 2.3 0 2.6 2.3 12/25/2005 17:40:00 7.3 1.2 10.7 3.8 6.9 1.3 11.1 3.4 5.7 1.2 8.8 2.6 39 14 41 300 2.4 0 2.6 2.3 12/25/2005 17:50:00 7.4 1.3 10.7 3 6.9 1.3 10.3 2.6 6 1.3 10.3 3 37 13 17 300 2.3 0 2.6 2.3 12/25/2005 18:00:00 7.1 1.1 9.9 4.2 6.4 1.2 9.9 3.4 5.4 1.3 8.8 2.3 33 11 36 300 2.4 0 2.6 2.3 12/25/2005 18:10:00 6.8 1 9.9 4.6 6.3 1.1 9.1 3.8 5.3 1.2 9.1 2.3 32 12 43 300 2.5 0 2.6 2.3 12/25/2005 18:20:00 7.2 1.1 10.3 4.2 6.4 1.1 9.9 3.8 5.5 1 8.8 3 29 10 41 300 2.5 0 2.6 2.6 12/25/2005 18:30:00 7.3 1.1 10.3 4.6 6.7 1.1 9.5 3.4 5.8 1.1 8.4 2.6 33 11 21 300 2.5 0 2.6 2.3 12/25/2005 18:40:00 7.4 1.3 10.3 4.9 6.6 1.3 9.9 3.4 5.5 1.2 9.1 3 26 13 38 300 2.3 0 2.6 2.3 12/25/2005 18:50:00 7.4 1 10.7 4.9 6.6 1.1 9.9 3.4 5.6 1.1 8.8 3 29 11 15 300 2.3 0 2.6 2.3 12/25/2005 19:00:00 7.7 1.2 10.7 4.2 6.8 1.2 10.7 3.8 5.8 1.1 9.1 3.4 26 11 28 300 2.3 0 2.3 2.3 12/25/2005 19:10:00 7.7 1.2 10.3 4.9 6.8 1.2 9.9 3.8 5.9 1.1 9.5 3 25 10 22 300 2.4 0 2.6 2.3 12/25/2005 19:20:00 8 1.3 11.5 3.4 7 1.3 11.1 3.8 5.8 1.1 9.5 3.4 27 11 38 300 2.6 0 2.8 2.6 12/25/2005 19:30:00 8.1 1.3 11.5 4.6 7.3 1.4 11.5 3.4 5.9 1.3 9.5 2.3 32 11 28 300 2.7 0 2.8 2.8 12/25/2005 19:40:00 7.6 1.2 11.1 4.6 6.9 1.3 11.1 3.8 5.9 1.3 9.9 3.4 33 13 32 300 2.9 0 2.8 2.8 12/25/2005 19:50:00 8 1.3 11.1 4.2 7.4 1.3 10.7 4.2 6.2 1.4 10.3 2.6 35 12 36 300 2.9 0 2.8 2.8 12/25/2005 20:00:00 7.8 1.2 10.3 4.9 7.1 1.2 9.9 4.2 5.8 1.2 9.1 3.4 33 11 34 300 2.9 0 3 2.8 12/25/2005 20:10:00 7.8 1.2 10.3 3.8 7.1 1.2 10.3 3.4 5.8 1.4 9.1 2.3 34 12 38 300 2.9 0 3 2.8 12/25/2005 20:20:00 8 1.1 10.7 4.2 7.4 1.2 10.3 4.6 5.9 1.3 9.1 3 37 12 47 300 3 0 3.3 2.8 12/25/2005 20:30:00 7.2 1.3 10.3 3.4 6.6 1.3 9.9 2.6 5.5 1.2 9.9 2.6 34 15 26 300 2.9 0 3 2.8 12/25/2005 20:40:00 8.3 1.2 11.8 4.9 7.6 1.3 11.1 4.2 6.4 1.5 10.7 3 35 11 30 300 2.9 0 3.3 2.8 12/25/2005 20:50:00 7.7 1.3 10.7 3.8 6.9 1.2 9.9 3 5.8 1.3 9.1 3 31 13 20 300 3.1 0 3.3 3 12/25/2005 21:00:00 8.1 1.2 11.5 5.3 7.3 1.2 10.7 4.6 6.1 1.1 10.3 3.4 30 12 28 300 3.1 0 3.3 3 12/25/2005 21:10:00 7.9 1.5 11.5 3.8 7 1.4 10.7 3.4 5.9 1.4 9.9 2.3 30 12 25 300 3 0 3.3 2.8 12/25/2005 21:20:00 8.2 1.2 11.5 5.3 7.3 1.2 10.7 4.6 6.2 1.3 9.5 3.4 29 11 36 300 3.2 0 3.3 3 12/25/2005 21:30:00 8.8 1.3 11.8 4.6 7.7 1.2 10.7 3.8 6.4 1.4 11.1 2.6 25 10 38 300 3.2 0 3.5 3.3 12/25/2005 21:40:00 9.1 1.5 14.5 5.3 8.1 1.5 13 4.6 6.7 1.3 10.7 3.8 26 12 37 300 3.1 0 3.3 2.8 12/25/2005 21:50:00 8.2 1.9 13 4.2 7.4 1.8 12.6 3.8 6.4 1.6 11.1 2.3 25 13 24 300 2.9 0 3 2.8 12/25/2005 22:00:00 7.3 1.6 11.5 3.4 6.8 1.6 11.8 3.4 5.7 1.5 10.7 2.6 31 17 30 300 2.7 0 2.8 2.6 12/25/2005 22:10:00 8.1 1.5 11.5 2.6 7.3 1.4 11.8 2.6 6.2 1.2 10.7 3.4 23 13 22 300 2.6 0 2.8 2.6 12/25/2005 22:20:00 8.1 1.5 11.8 4.6 7.2 1.4 11.1 3.8 6.3 1.3 10.3 3 24 13 31 300 2.6 0 2.8 2.6 12/25/2005 22:30:00 7.8 1.4 11.1 3.4 7 1.3 10.3 3.4 5.8 1.3 9.9 3 24 11 26 300 2.9 0 2.8 2.8 12/25/2005 22:40:00 6.5 1.2 9.9 3.4 6 1.2 9.9 3 5 1.2 8.4 2.3 24 15 17 300 3 0.1 3.3 2.8 12/25/2005 22:50:00 6.5 1.4 9.1 3.4 6 1.3 9.1 3.4 5 1.3 8 1.9 31 15 21 300 3.3 0 3.5 3.3 12/25/2005 23:00:00 8.2 1.7 11.5 3.8 7.3 1.6 11.1 3.8 6.2 1.5 11.1 2.6 24 12 31 300 3.4 0 3.5 3.3 12/25/2005 23:10:00 9 1.3 11.5 5.3 8.2 1.3 11.8 4.2 6.9 1.3 10.7 3 20 11 25 300 3.2 0 3.5 3 12/25/2005 23:20:00 7.9 1.4 10.7 3.8 7.7 1.6 11.5 3.8 6.4 1.5 9.9 3.4 13 11 12 300 2.9 0 3.3 2.8 12/25/2005 23:30:00 7.6 1.5 11.8 3.8 7.1 1.6 12.2 3.8 6.1 1.5 10.3 2.3 17 12 16 300 2.7 0 2.8 2.6 12/25/2005 23:40:00 6.5 1.1 9.5 4.2 6 1.2 9.5 3.4 5.2 1.1 8.4 3 28 14 15 300 2.7 0 2.8 2.8 12/25/2005 23:50:00 7.7 1.6 11.5 3.8 6.9 1.6 11.5 3.4 5.8 1.4 9.1 2.6 23 13 23 300 2.9 0 2.8 2.8 12/26/2005 00:00:00 8.7 1.5 12.2 4.6 7.9 1.5 12.2 3.8 6.8 1.4 9.9 3.4 21 11 20 300 3 0.1 3.3 2.8 12/26/2005 00:10:00 9.5 1.4 13 5.3 8.9 1.5 13 4.2 7.3 1.5 11.8 3.8 19 11 35 300 3 0 3.3 2.8 12/26/2005 00:20:00 9.8 1.5 14.1 6.1 8.7 1.5 12.2 5.3 7.4 1.4 11.8 3.8 23 10 24 300 2.9 0 3.3 2.8 12/26/2005 00:30:00 8.9 1.5 12.6 4.6 8.2 1.5 12.2 3.4 6.8 1.5 10.3 3 18 11 32 300 2.9 0 3 2.8 12/26/2005 00:40:00 10.1 1.7 13.7 5.3 9.3 1.7 14.5 4.6 7.9 1.6 13 4.2 21 12 7 300 3 0 3.3 2.8 12/26/2005 00:50:00 9.4 1.6 13 4.9 8.5 1.5 13.7 4.6 7.5 1.7 11.5 3.8 23 12 30 300 3 0 3.3 2.8 12/26/2005 01:00:00 9.8 1.5 13.7 5.7 8.8 1.6 12.6 4.9 7.4 1.5 12.2 3.8 23 11 24 300 3.2 0 3.5 2.8 12/26/2005 01:10:00 9.3 1.5 13.3 6.1 8.4 1.4 12.6 5.3 7.1 1.5 11.8 3 30 13 23 300 3.5 0.1 3.8 3.3 12/26/2005 01:20:00 9.1 1.5 13.3 4.2 8.3 1.5 12.6 3.8 7.1 1.5 12.2 3.4 32 13 25 300 3.5 0 3.5 3.5 12/26/2005 01:30:00 9.2 1.6 13 3.8 8.3 1.6 12.2 3.8 6.9 1.5 11.5 3 27 11 30 300 3.3 0 3.5 3.3 12/26/2005 01:40:00 8.8 1.6 12.6 4.9 7.9 1.5 12.6 4.2 6.8 1.5 10.7 2.3 27 13 27 300 3.2 0 3.5 3.3 12/26/2005 01:50:00 9.1 1.5 13.3 5.3 8.1 1.4 12.2 4.6 6.9 1.3 10.3 3.4 29 12 25 300 3.2 0 3.5 3.3 12/26/2005 02:00:00 9.4 1.6 13.3 4.6 8.4 1.5 12.2 3.8 7 1.5 11.5 3.4 23 12 28 300 3.2 0 3.5 3.3 12/26/2005 02:10:00 9.3 1.5 12.6 5.3 8.3 1.5 12.2 4.6 6.8 1.4 11.1 3 23 11 26 300 3.3 0 3.5 3.3 12/26/2005 02:20:00 8.4 1.5 12.6 4.2 7.7 1.5 12.2 3.4 6.7 1.6 11.8 2.3 25 13 18 300 3.3 0 3.5 3.3 12/26/2005 02:30:00 7.7 1.5 11.5 3.4 6.9 1.3 10.7 3.8 5.8 1.3 9.5 3 27 12 27 300 3.2 0 3.5 3.3 12/26/2005 02:40:00 8.7 1.1 11.8 5.7 7.8 1.1 11.1 5.3 6.4 1 9.5 3.4 27 11 27 300 3.5 0.1 3.8 3.3 12/26/2005 02:50:00 8.3 1.5 11.5 4.6 7.6 1.5 11.8 3.8 6.6 1.4 10.7 3 21 12 25 300 3.6 0 3.8 3.5 12/26/2005 03:00:00 9.6 1.5 13 5.7 8.6 1.5 13.3 4.6 7.2 1.5 11.1 3 22 11 17 300 3.5 0 3.8 3.5 12/26/2005 03:10:00 9.3 1.4 13 5.7 8.2 1.2 11.8 4.6 6.7 1.2 9.9 3.8 28 12 31 300 3.7 0 3.8 3.5 12/26/2005 03:20:00 8.9 1.6 12.6 4.2 7.9 1.5 11.5 3.8 6.7 1.5 11.8 3 25 10 24 300 3.7 0 3.8 3.5 12/26/2005 03:30:00 7.5 1.3 11.5 3.8 6.8 1.3 9.9 3.4 5.9 1.2 9.9 3.4 33 13 28 300 3.8 0 4 3.8 12/26/2005 03:40:00 8 1.4 11.5 4.2 7.2 1.3 10.7 3.4 6.1 1.3 10.3 3 29 11 15 300 4 0 4 3.8 12/26/2005 03:50:00 6.6 1.1 9.1 3.4 6.2 1.2 8.8 2.6 5.3 1.3 8.8 2.3 35 13 45 300 4 0 4.3 4 12/26/2005 04:00:00 6.5 1.5 9.9 2.3 6 1.3 9.5 2.3 5 1.3 9.1 2.3 32 15 21 300 4 0 4 3.8 12/26/2005 04:10:00 6.5 1.5 10.3 1.9 5.9 1.5 9.5 2.3 4.9 1.3 8.8 2.3 25 15 28 300 4 0 4 3.8 12/26/2005 04:20:00 5.5 1.3 9.1 2.6 5.1 1.2 8 2.3 4.3 1.4 8.4 1.5 31 15 18 300 3.9 0 4 3.8 12/26/2005 04:30:00 4.3 1 6.8 1.1 4.2 1 6.5 1.5 3.6 1 6.1 1.1 49 15 48 300 3.7 0.1 3.8 3.5 12/26/2005 04:40:00 4.4 1.3 8.4 0.7 4.2 1.3 8.8 0.7 3.5 1.2 7.2 1.1 41 20 72 300 3.6 0 3.8 3.5 12/26/2005 04:50:00 6.3 1.3 9.9 3.4 6 1.3 9.9 3 4.9 1.4 8.8 1.5 37 16 14 300 3.5 0 3.5 3.5 12/26/2005 05:00:00 6.1 1.2 9.1 3 5.8 1.2 9.1 2.6 4.9 1.5 8.4 1.5 43 15 24 300 3.4 0 3.5 3.3 12/26/2005 05:10:00 7.1 1.6 11.8 3 6.4 1.4 10.3 2.3 5.3 1.3 8.4 1.9 33 15 31 300 3.4 0 3.5 3.3 12/26/2005 05:20:00 7.8 1.5 11.8 3.8 7.2 1.3 11.1 4.2 5.8 1.3 10.3 3 30 16 27 300 3.2 0 3.5 3 12/26/2005 05:30:00 7.7 1.7 11.8 3.4 7 1.6 11.1 3 6 1.5 9.5 2.6 32 15 34 300 3.1 0 3.3 3 12/26/2005 05:40:00 7.7 1.5 11.8 4.2 6.9 1.5 10.7 3.8 5.9 1.3 10.7 3 29 12 36 300 3.2 0 3.5 3.3 12/26/2005 05:50:00 8.5 1.3 12.6 5.7 7.6 1.2 11.5 4.6 6.7 1.3 9.9 3.8 29 12 20 300 3.4 0 3.5 3.3 12/26/2005 06:00:00 8.5 1.3 11.5 4.9 7.6 1.3 11.1 4.6 6.4 1.2 9.9 3.4 26 13 10 300 3.3 0 3.5 3.3 12/26/2005 06:10:00 8 1.5 11.8 4.2 7.2 1.5 10.7 4.2 6.1 1.3 9.5 3.4 22 11 24 300 3.2 0 3.3 3.3 12/26/2005 06:20:00 8.3 1.4 11.8 4.6 7.5 1.5 12.2 4.2 6.3 1.3 10.7 3 25 12 17 300 3.3 0 3.5 3.3 12/26/2005 06:30:00 8.4 1.3 11.8 4.6 7.7 1.5 11.1 3.8 6.4 1.5 11.1 2.3 22 12 26 300 3.5 0 3.5 3.5 12/26/2005 06:40:00 8.8 1.9 12.6 3.8 8.5 2.2 12.6 3 7.1 2 11.8 2.3 14 13 2 300 3.6 0 3.8 3.5 12/26/2005 06:50:00 8.7 1.5 11.8 4.2 8.4 1.7 12.6 3.8 6.9 1.6 11.1 3.4 12 13 24 300 3.5 0 3.5 3.5 12/26/2005 07:00:00 8.7 1.7 12.6 3.4 8.3 2 13 3 6.9 1.9 11.8 2.6 14 13 20 300 3.5 0 3.5 3.3 12/26/2005 07:10:00 8.8 1.7 12.6 4.2 8.4 1.7 13 3.8 6.7 1.9 13 2.6 12 15 26 300 3.3 0 3.5 3.3 12/26/2005 07:20:00 8.8 1.7 12.6 4.6 8.3 1.9 13.3 3.8 6.9 1.8 11.8 2.6 16 13 17 300 3.3 0 3.5 3.3 12/26/2005 07:30:00 8.5 1.5 11.8 4.9 7.7 1.5 11.5 3.8 6.3 1.3 9.5 2.6 22 12 14 300 3.4 0 3.5 3.3 12/26/2005 07:40:00 8.8 1.2 11.8 5.7 8 1.2 11.5 4.9 6.5 1.3 10.3 2.3 18 10 13 300 3.4 0 3.5 3.3 12/26/2005 07:50:00 7.8 1.7 11.1 3 7 1.7 11.1 2.6 5.9 1.6 11.1 1.9 23 12 19 300 3.3 0 3.5 3.3 12/26/2005 08:00:00 7.6 1.4 11.8 4.2 6.8 1.4 11.8 3 5.8 1.4 9.1 2.6 24 14 16 300 3.4 0 3.5 3.5 12/26/2005 08:10:00 8.5 1.4 12.2 4.6 7.8 1.5 12.2 4.2 6.5 1.4 11.5 3 18 12 31 300 3.4 0 3.5 3.5 12/26/2005 08:20:00 8.7 1.5 12.2 4.2 8 1.5 11.5 4.6 6.6 1.3 10.3 3 19 12 20 300 3.6 0 3.8 3.5 12/26/2005 08:30:00 7.8 1.7 11.5 3.4 7.3 1.7 11.5 3 5.9 1.6 10.7 2.3 27 17 26 300 3.5 0 3.5 3.5 12/26/2005 08:40:00 7.5 1.8 12.2 3.4 6.7 1.7 11.8 3.4 5.9 1.5 11.5 2.6 25 15 27 300 3.7 0 3.8 3.5 12/26/2005 08:50:00 7 1.3 11.1 4.2 6.6 1.3 10.7 3.4 5.5 1.3 9.5 1.9 36 14 28 300 3.6 0 3.8 3.5 12/26/2005 09:00:00 7.9 1.4 11.8 4.2 7.1 1.2 10.3 3.8 5.8 1.3 8.8 2.6 28 12 11 300 3.6 0 3.8 3.5 12/26/2005 09:10:00 8.5 1.6 13.7 4.6 7.7 1.5 13 3.4 6.6 1.7 11.8 3 31 14 38 300 3.8 0 4 3.8 12/26/2005 09:20:00 8.7 1.5 13 4.6 8.1 1.5 13 4.2 6.7 1.6 10.7 1.5 35 13 42 300 3.8 0 4 3.8 12/26/2005 09:30:00 9.7 1.5 13.3 6.1 8.7 1.5 12.6 4.9 7.3 1.5 12.6 3 29 12 24 300 3.6 0 3.8 3.5 12/26/2005 09:40:00 9.2 1.6 13 4.9 8.3 1.5 13.3 4.2 7 1.5 11.5 3.4 28 13 45 300 3.8 0 3.8 3.5 12/26/2005 09:50:00 8.5 1.7 12.6 4.2 7.7 1.5 12.2 4.2 6.7 1.5 11.5 3 29 15 33 300 3.8 0 4 3.8 12/26/2005 10:00:00 9.7 1.5 13.3 5.3 8.5 1.5 12.2 4.6 7.3 1.4 11.5 3 26 11 30 300 4 0 4 4 12/26/2005 10:10:00 10 1.7 13.3 4.9 8.8 1.6 12.6 4.6 7.5 1.5 11.8 3 27 10 25 300 4 0 4 4 12/26/2005 10:20:00 9.6 1.7 13.7 4.6 8.6 1.7 12.6 4.6 7.3 1.5 12.2 3.4 28 12 27 300 4 0 4.3 4 12/26/2005 10:30:00 9.8 1.5 13.3 4.9 8.7 1.4 12.2 3.4 7.4 1.5 12.2 3 27 10 37 300 4 0 4.3 4 12/26/2005 10:40:00 9.3 1.5 12.2 4.9 8.2 1.4 11.8 3.8 6.8 1.4 11.1 3.8 27 11 20 300 4 0 4.5 3.8 12/26/2005 10:50:00 8.9 1.5 12.2 4.9 8 1.5 13 4.6 7 1.4 11.5 3.4 26 13 31 300 4.4 0 4.5 4.3 12/26/2005 11:00:00 8.8 1.6 13.3 4.6 7.9 1.5 13 3.8 6.8 1.4 11.1 2.6 25 11 37 300 4 0 4.3 4 12/26/2005 11:10:00 8.3 1.2 11.5 5.3 7.5 1.3 11.5 4.6 6.5 1.4 10.7 3.4 21 11 13 300 4 0 4.3 4 12/26/2005 11:20:00 8.1 1.2 11.8 4.6 7.3 1.2 11.8 4.2 6.1 1.3 9.9 1.9 22 13 50 300 4.1 0 4.3 4 12/26/2005 11:30:00 8.3 1.5 12.6 4.9 7.4 1.5 12.2 4.2 6.5 1.4 11.1 3.4 24 10 35 300 4.1 0 4.5 4 12/26/2005 11:40:00 8.7 1.5 12.6 4.6 7.7 1.5 12.2 4.2 6.6 1.3 10.3 3.4 26 11 23 300 4.2 0 4.3 4 12/26/2005 11:50:00 9.1 1.1 11.5 5.7 8 1.2 11.5 4.9 6.4 1.1 9.9 3.4 26 9 20 300 4.4 0 4.8 4.3 12/26/2005 12:00:00 10.2 1.1 12.6 6.1 8.8 1.1 12.2 4.6 7.3 1.3 11.5 3.8 26 8 27 300 4.5 0 4.8 4.5 12/26/2005 12:10:00 9.8 1.3 13 4.9 8.7 1.3 13 4.9 7.2 1.3 11.8 3.8 30 10 40 300 4.6 0 5 4.5 12/26/2005 12:20:00 9.6 1.5 13 3.8 8.8 1.4 12.6 3.8 7 1.3 11.5 3 33 12 35 300 5.1 0 5.2 4.8 12/26/2005 12:30:00 9.8 1.2 12.6 6.5 8.7 1.3 11.8 4.9 7.2 1.3 10.7 3.4 31 10 28 300 5 0 5.2 5 12/26/2005 12:40:00 9.1 1.2 12.2 6.1 8.5 1.3 12.2 4.9 6.7 1.4 10.7 3.4 37 11 48 300 4.9 0 5 4.8 12/26/2005 12:50:00 8.8 1.3 11.8 5.3 8 1.4 11.8 4.2 6.6 1.5 11.5 3.4 32 13 27 300 5.1 0 5.2 5 12/26/2005 13:00:00 9.1 1.5 12.2 4.2 8.2 1.5 12.6 3.8 6.8 1.5 11.5 3.4 29 11 24 300 4.8 0 5 4.5 12/26/2005 13:10:00 8.8 1.5 12.2 4.2 8 1.4 11.8 3.4 6.7 1.3 11.1 3 32 12 43 300 4.8 0.1 5 4.5 12/26/2005 13:20:00 8.7 1.3 11.5 4.9 7.8 1.3 11.5 3.8 6.5 1.3 9.9 2.6 26 12 32 300 4.6 0 4.8 4.5 12/26/2005 13:30:00 8.4 1.3 11.1 4.9 7.5 1.3 11.1 4.2 6.4 1.3 9.9 3.4 26 11 31 300 4.9 0 5 4.8 12/26/2005 13:40:00 8.5 1.3 11.1 4.9 7.5 1.3 11.5 4.2 6.1 1.3 10.3 1.9 26 12 9 300 4.9 0 5 4.8 12/26/2005 13:50:00 8.6 1.4 11.5 3.8 7.6 1.4 11.1 3.8 6.3 1.3 10.3 3 29 10 28 300 4.9 0 5.2 4.8 12/26/2005 14:00:00 7.4 1.1 10.3 4.6 6.6 1.1 9.1 3.8 5.5 1 9.1 3 23 10 26 300 5.1 0 5 5 12/26/2005 14:10:00 7.8 1.2 10.3 3.8 6.9 1.2 9.9 3.4 5.7 1.2 9.5 2.3 23 9 18 300 5.2 0 5.2 5 12/26/2005 14:20:00 7.2 1.3 10.7 2.6 6.4 1.3 10.7 2.3 5.4 1.1 9.1 3 27 11 34 300 5.1 0 5 5 12/26/2005 14:30:00 8 1.3 11.5 4.2 7.1 1.3 11.1 3.8 6.1 1.2 9.5 2.6 27 12 32 300 4.8 0 5 4.8 12/26/2005 14:40:00 8.2 1.3 11.8 3.8 7.2 1.3 12.2 4.2 6.1 1.2 11.1 2.6 24 9 24 300 4.6 0 4.8 4.5 12/26/2005 14:50:00 7.9 1.3 10.7 4.9 7.4 1.4 10.7 3.8 6.1 1.5 10.3 2.6 16 12 17 300 4.6 0 4.8 4.5 12/26/2005 15:00:00 8.3 1.3 10.7 4.6 7.6 1.3 11.5 3.8 6.3 1.3 10.7 2.6 21 11 7 300 4.3 0 4.5 4.3 12/26/2005 15:10:00 7.1 1.7 11.5 3.4 6.5 1.5 11.1 2.6 5.4 1.4 10.3 2.3 22 13 30 300 4.3 0 4.5 4.3 12/26/2005 15:20:00 6.5 1.5 9.9 3 6 1.5 10.3 2.3 5 1.3 9.5 1.9 21 14 37 300 4.2 0 4.5 4 12/26/2005 15:30:00 6.2 1.2 9.1 2.6 5.7 1.2 9.1 2.6 4.7 1.1 8.4 1.9 24 13 14 300 4 0 4.3 3.8 12/26/2005 15:40:00 5.8 1 9.1 3.4 5.2 1.1 9.1 2.6 4.4 1 8 1.9 23 12 0 300 3.7 0.1 4 3.5 12/26/2005 15:50:00 5.7 1.3 8.4 2.6 5.2 1.3 9.1 2.6 4.4 1.2 7.2 1.9 30 14 17 300 3.5 0 3.5 3.5 12/26/2005 16:00:00 6.7 1.1 9.1 3.4 6 1.1 9.1 2.6 5.1 1.1 8.4 2.3 32 11 24 300 3.5 0 3.5 3.5 12/26/2005 16:10:00 5.3 1.5 8.8 1.5 4.8 1.4 8.4 1.5 4 1.3 7.2 1.1 30 17 23 300 3.3 0 3.5 3.3 12/26/2005 16:20:00 5.6 1.4 10.3 2.6 5.2 1.3 9.5 2.3 4.4 1.2 8 1.9 36 17 31 300 3.1 0 3.3 2.8 12/26/2005 16:30:00 6.6 1.1 9.9 4.2 6.2 1.1 9.5 3.4 5.3 1.2 8.8 2.3 38 12 40 300 3 0 3.3 2.8 12/26/2005 16:40:00 7.2 1.3 10.3 3.8 6.7 1.3 9.9 3 5.5 1.5 9.5 2.3 35 14 40 300 3.2 0 3.3 3 12/26/2005 16:50:00 5.5 1.1 8.8 2.6 5.3 1.1 8.4 2.6 4.4 1.3 8.4 1.5 38 15 34 300 3.1 0 3.3 2.8 12/26/2005 17:00:00 6.2 1 8.4 3 5.7 1 8.4 2.6 4.6 1 7.2 1.9 32 11 34 300 3 0 3.3 2.8 12/26/2005 17:10:00 5.9 1 8.4 3.4 5.4 1 8 3 4.4 0.9 7.2 1.9 24 13 29 300 3.1 0 3.3 3 12/26/2005 17:20:00 5.9 1.1 8.8 3.4 5.3 1 8 2.6 4.3 1 7.2 1.9 29 13 32 300 3.2 0 3.3 3.3 12/26/2005 17:30:00 6.5 1.2 9.5 3.8 5.8 1.1 8.4 3 4.9 1.1 7.6 2.3 27 12 7 300 3.2 0 3.5 3.3 12/26/2005 17:40:00 7.3 1 9.5 4.2 6.5 1 9.1 3.8 5.4 1 8.8 3 22 10 34 300 3.2 0 3.3 3.3 12/26/2005 17:50:00 7.4 1.2 10.3 4.2 6.6 1.3 10.7 3.8 5.3 1.1 8.8 3 23 11 13 300 3 0 3.3 2.8 12/26/2005 18:00:00 7.8 1.2 11.1 4.9 6.9 1.2 10.3 3.8 5.7 1.1 8.8 2.6 29 11 33 300 3.2 0 3.3 3 12/26/2005 18:10:00 7.4 1.4 10.7 2.6 6.6 1.3 9.5 2.3 5.3 1.2 8 1.9 26 12 25 300 3 0 3.3 2.8 12/26/2005 18:20:00 6.2 1.3 9.1 2.6 5.6 1.2 8.8 2.3 4.7 1.1 8 1.5 28 14 25 300 2.9 0 3 2.8 12/26/2005 18:30:00 5.6 1.2 8.4 2.6 5.2 1.2 8 2.3 4.2 1.2 8 1.1 27 17 14 300 2.7 0 2.8 2.6 12/26/2005 18:40:00 5.7 1.2 8.8 2.6 5.3 1.1 8 2.3 4.4 0.9 6.5 2.3 29 14 37 300 2.6 0 2.8 2.6 12/26/2005 18:50:00 6.8 1.2 9.9 3.4 6 1.2 9.5 3 5.1 1.1 8.8 2.3 27 11 33 300 2.7 0 2.8 2.6 12/26/2005 19:00:00 6.1 1.2 9.1 3 5.5 1.1 8.8 2.6 4.6 0.8 7.2 2.6 25 11 27 300 2.9 0 2.8 2.8 12/26/2005 19:10:00 6.4 1.2 9.1 3.8 5.7 1.2 9.9 3 4.8 1.2 8.8 2.6 25 12 22 300 2.9 0 2.8 2.8 12/26/2005 19:20:00 5.7 1 9.1 3 5.1 1.1 8.8 2.3 4.5 1 7.6 2.3 26 14 28 300 2.9 0 3 2.8 12/26/2005 19:30:00 6.1 1.2 9.5 3.4 5.5 1.1 8.8 2.6 4.7 1.1 7.6 1.9 25 13 31 300 2.9 0 3.3 2.8 12/26/2005 19:40:00 5.5 1.3 8.8 3 5.1 1.2 8.8 2.6 4.4 1.2 7.6 1.5 30 13 28 300 3 0 3.3 2.8 12/26/2005 19:50:00 4.7 1 7.6 1.9 4.4 1 7.6 1.9 3.7 1 6.1 1.5 33 13 30 300 2.9 0 3.3 2.8 12/26/2005 20:00:00 6 1.2 8.8 3 5.4 1.1 8.4 3 4.4 1 7.2 2.3 26 13 25 300 3.2 0.1 3.5 2.8 12/26/2005 20:10:00 6.2 1.3 10.3 3.4 5.6 1.2 9.5 2.3 4.7 1.3 7.6 0.7 28 15 24 300 3.3 0 3.5 3.3 12/26/2005 20:20:00 6 1 9.1 3.4 5.5 1 8.8 2.6 4.7 1 7.6 2.3 32 14 10 300 3 0.1 3.3 2.8 12/26/2005 20:30:00 5.9 1.3 9.9 3 5.4 1.2 9.5 3 4.4 1.2 8 2.3 32 15 33 300 2.8 0 2.8 2.6 12/26/2005 20:40:00 4.1 1.2 7.6 1.5 4 1.2 7.6 1.1 3.5 1.2 6.8 1.1 46 21 37 300 2.7 0 2.8 2.6 12/26/2005 20:50:00 2.8 1 5.7 0.4 2.8 1 6.1 0.4 2.6 1 5.3 0.4 71 30 61 300 2.3 0.2 2.6 1.8 12/26/2005 21:00:00 2.8 1 6.5 0.4 2.8 1 6.5 0.7 2.3 1 6.5 0.4 67 29 52 300 1.2 0.5 1.8 0.2 12/26/2005 21:10:00 2.2 1.2 5.7 0.4 2.2 1.2 5.7 0.4 1.9 1.1 5.7 0.4 64 32 48 300 0.7 0.1 1.4 0.4 12/26/2005 21:20:00 4.1 1.3 7.2 1.1 3.9 1.3 7.2 1.1 3.5 1.1 7.6 1.5 41 21 35 300 2 0.4 2.6 1.4 12/26/2005 21:30:00 3 1 5.7 0.7 3 1 5.7 0.4 2.8 0.8 4.6 0.4 66 32 47 300 1.8 0.9 2.8 -0.1 12/26/2005 21:40:00 2.6 0.8 4.6 1.1 2.7 0.8 4.6 0.7 2.2 0.8 4.6 0.4 60 22 62 300 0.3 0.2 0.9 -0.1 12/26/2005 21:50:00 3.2 1 5.7 0.7 3.3 1 5.7 1.1 2.9 0.9 5.3 0.7 79 22 86 300 0.8 0.2 1.4 -0.1 12/26/2005 22:00:00 2.4 0.6 4.2 0.7 2.5 0.7 4.2 0.7 2.2 0.5 3.8 1.1 83 16 104 300 -0.8 0.2 -0.1 -1 12/26/2005 22:10:00 2.4 0.7 4.6 0.7 2.5 0.7 4.2 0.7 1.9 0.5 3.8 0.7 87 35 88 300 -0.8 0 -0.5 -1 12/26/2005 22:20:00 2.3 1.1 4.9 0.4 2.2 1 4.6 0.4 1.6 0.8 4.6 0.4 55 33 18 300 -0.9 0.3 -0.3 -1.2 12/26/2005 22:30:00 3.9 1.2 6.8 1.1 3.9 1.2 6.8 1.1 3 1 5.7 0.4 50 16 43 300 0.2 0.3 0.9 -0.3 12/26/2005 22:40:00 4.2 1.2 7.6 1.5 4.1 1.2 8 1.5 3.3 1.2 7.2 0.7 49 16 37 300 1.4 0.2 1.6 0.9 12/26/2005 22:50:00 4.8 1.3 8 0.7 4.6 1.3 8 1.1 3.7 1.2 7.6 1.5 40 17 11 300 1.7 0 2.1 1.6 12/26/2005 23:00:00 4.9 1.2 8.4 1.9 4.6 1.2 7.6 1.5 3.9 1.2 7.6 1.5 37 17 34 300 1.8 0 2.1 1.8 12/26/2005 23:10:00 5.8 1.3 9.5 3 5.3 1.2 9.1 2.3 4.3 1.1 8 2.3 33 13 30 300 1.9 0.1 2.3 1.8 12/26/2005 23:20:00 5.6 1.1 8.8 3 5.2 1 8.4 3 4.2 1.1 8.4 1.9 31 13 42 300 2.1 0 2.3 2.1 12/26/2005 23:30:00 6.3 1.5 10.3 2.6 5.7 1.3 9.5 2.3 4.7 1.2 7.6 1.1 29 13 23 300 2.3 0 2.6 2.3 12/26/2005 23:40:00 7.2 1.6 11.1 2.3 6.5 1.5 9.9 2.6 5.6 1.3 10.7 2.3 27 14 25 300 2.4 0 2.6 2.3 12/26/2005 23:50:00 7.5 1.6 11.5 3.8 6.8 1.5 11.1 3.4 5.8 1.2 9.5 3 30 16 38 300 2.6 0 2.8 2.6 12/27/2005 00:00:00 7.7 1.6 11.8 4.2 7.2 1.5 12.2 3.8 5.9 1.3 9.9 2.6 34 15 47 300 2.7 0 2.8 2.6 12/27/2005 00:10:00 7.6 1.3 11.5 3.4 7 1.4 10.7 3.8 5.7 1.3 9.1 3 34 12 45 300 2.7 0 2.8 2.6 12/27/2005 00:20:00 7.3 1.2 10.3 4.2 6.6 1.2 10.3 3.8 5.5 1.2 8.8 1.9 31 12 36 300 2.7 0 2.8 2.6 12/27/2005 00:30:00 6.8 1.2 9.9 3.4 6.2 1.2 9.5 3 5.2 1.1 8.8 2.3 34 12 42 300 2.9 0 3 2.8 12/27/2005 00:40:00 6.7 1.2 9.9 3.4 6.2 1.3 9.1 3 5.1 1.2 9.1 2.3 37 12 34 300 3.2 0 3.5 2.8 12/27/2005 00:50:00 5.9 1 9.1 3.4 5.4 1 8.4 3 4.5 1 8 1.9 34 12 36 300 3.2 0 3.5 3 12/27/2005 01:00:00 5.5 0.9 8.4 3.4 5.1 1 8.4 2.6 4.2 1 7.2 1.1 35 11 44 300 3 0 3.3 2.8 12/27/2005 01:10:00 6.3 1.2 8.8 2.6 5.8 1.2 8.8 2.6 5 1.1 8 1.9 34 12 20 300 2.9 0 3 2.8 12/27/2005 01:20:00 6 1 8.8 4.2 5.4 1 8.8 3.4 4.6 1 8 2.3 29 11 43 300 2.7 0 2.8 2.6 12/27/2005 01:30:00 5.9 1.2 9.5 2.6 5.4 1.2 9.1 3 4.4 1 8 1.5 33 13 53 300 2.6 0 2.8 2.6 12/27/2005 01:40:00 7.2 1.2 10.3 4.2 6.7 1.3 9.9 3.4 5.6 1.2 9.5 2.6 36 11 34 300 2.6 0 2.8 2.6 12/27/2005 01:50:00 7.8 1.2 10.7 4.6 7 1.2 10.3 3.8 5.8 1.2 9.5 3 29 12 25 300 2.7 0 2.8 2.6 12/27/2005 02:00:00 7.8 1.3 11.1 4.2 7 1.3 10.3 3.8 5.8 1.2 9.9 2.3 28 12 34 300 2.6 0 2.8 2.6 12/27/2005 02:10:00 7.8 1.5 11.1 4.6 7 1.3 10.3 4.2 6.1 1.3 11.1 2.6 29 12 24 300 2.9 0 3 2.8 12/27/2005 02:20:00 7 1.5 11.8 3.8 6.3 1.5 10.7 3 5.3 1.4 8.8 1.5 30 13 31 300 3 0 3.3 2.8 12/27/2005 02:30:00 6.2 1.2 9.1 3 5.7 1.2 8.4 2.6 4.7 1.2 8.4 1.9 29 13 33 300 2.9 0 3.3 2.8 12/27/2005 02:40:00 5.9 1.1 8.4 3 5.4 1.1 8 2.6 4.5 1.1 8 1.5 32 11 39 300 3.1 0 3.3 2.8 12/27/2005 02:50:00 5.4 1.3 9.5 2.6 5 1.3 9.1 2.3 4.1 1.3 7.6 1.5 34 14 45 300 3.2 0 3.5 3.3 12/27/2005 03:00:00 5.5 1 8 3.4 5 1 8 2.6 3.9 1 7.2 1.5 29 12 15 300 3.1 0 3.3 3 12/27/2005 03:10:00 5.4 1.1 8.4 2.3 5.1 1.2 8.4 2.3 4 1.1 7.2 1.9 41 12 45 300 2.9 0 3.3 2.8 12/27/2005 03:20:00 6.1 1.1 8.8 3.4 5.6 1 8.4 3 4.3 1.1 7.2 1.1 35 11 35 300 2.9 0 2.8 2.8 12/27/2005 03:30:00 6.2 1.1 8.4 3 5.5 1 8 2.6 4.7 1 7.2 2.3 26 11 27 300 2.9 0 2.8 2.8 12/27/2005 03:40:00 6 0.9 8 3.4 5.4 0.9 8 3 4.6 0.8 6.8 2.6 27 11 14 300 2.9 0 2.8 2.8 12/27/2005 03:50:00 5.8 0.9 7.6 3.4 5.1 0.9 8 2.6 4.3 0.9 6.5 1.9 27 10 34 300 2.9 0 2.8 2.8 12/27/2005 04:00:00 6.2 0.9 8 3 5.5 0.8 7.6 3 4.4 0.9 6.8 2.3 24 9 22 300 2.7 0 2.8 2.8 12/27/2005 04:10:00 6.9 0.8 9.5 4.6 6 0.8 8.8 3.8 5 0.8 7.2 2.6 24 8 30 300 2.9 0 3 2.8 12/27/2005 04:20:00 6.7 1.1 9.5 3.8 6 1.1 8.8 3 4.9 1 8 2.6 22 10 20 300 3.1 0 3.5 2.8 12/27/2005 04:30:00 6.5 1 9.1 4.2 5.8 1.1 8.4 3 4.9 1 8 2.3 28 9 36 300 3.3 0 3.5 3.3 12/27/2005 04:40:00 6.4 1.1 8.8 3.4 5.8 1 7.6 3 4.6 1.1 7.6 2.3 34 12 24 300 3.3 0 3.5 3.3 12/27/2005 04:50:00 7.2 1.3 10.3 3.4 7 1.4 10.3 3 5.4 1.3 9.5 3 42 13 38 300 3.4 0 3.5 3.3 12/27/2005 05:00:00 6.9 1.6 11.1 2.3 6.7 1.7 11.1 1.9 5.2 1.7 9.9 0.4 47 17 38 300 3.3 0 3.5 3.3 12/27/2005 05:10:00 8.5 2.1 13.7 3.8 8.2 2.1 13.7 3.8 6.6 2.1 12.2 2.6 41 15 44 300 3.3 0 3.5 3.3 12/27/2005 05:20:00 8.5 1.5 12.6 4.2 7.8 1.5 12.6 3.4 6.6 1.5 10.7 1.9 34 13 37 300 3.3 0 3.5 3.3 12/27/2005 05:30:00 6.9 1.2 9.9 3.8 6.6 1.2 9.9 3 5.3 1.4 8.8 1.9 40 14 43 300 3.1 0 3.3 3 12/27/2005 05:40:00 5.6 1.1 8.4 2.3 5.2 1.1 8 1.9 4.3 1.1 7.6 2.3 37 12 37 300 3 0 3.3 2.8 12/27/2005 05:50:00 6.5 1.4 9.9 3 5.9 1.3 9.5 3 4.9 1.2 9.1 1.9 26 12 27 300 3.3 0 3.5 3.3 12/27/2005 06:00:00 6.2 1.4 9.5 3 5.7 1.3 8.8 2.6 4.7 1.2 8.8 2.3 31 13 33 300 3.3 0 3.5 3.3 12/27/2005 06:10:00 5.5 1.1 9.5 2.6 5.2 1.1 8.8 2.6 4.2 1.1 9.1 1.9 37 12 36 300 3.3 0 3.5 3.3 12/27/2005 06:20:00 4.9 1.1 7.6 1.1 4.5 1 6.8 1.5 3.9 1 6.1 0.4 33 13 23 300 3.4 0 3.5 3.3 12/27/2005 06:30:00 4.2 0.9 6.1 1.5 4 0.9 5.7 1.9 2.9 0.8 5.3 1.1 42 17 19 300 3 0.1 3.3 2.8 12/27/2005 06:40:00 5 0.7 6.8 2.6 5 0.8 6.5 2.6 3.8 0.9 6.5 1.5 42 9 51 300 2.9 0 3 2.8 12/27/2005 06:50:00 5.6 0.9 8 3 5.3 0.9 7.6 2.6 4.3 1 7.2 2.3 34 11 17 300 3 0 3.3 2.8 12/27/2005 07:00:00 6.2 1 8.8 3.4 5.6 1.1 8 2.6 4.7 1 8 2.6 25 10 21 300 3 0 3.3 2.8 12/27/2005 07:10:00 6.3 1 9.1 3.8 5.7 1 9.1 3.4 4.8 0.8 7.6 2.3 25 11 32 300 2.9 0 3.3 2.8 12/27/2005 07:20:00 6.3 1 9.1 3.4 5.6 1 8.4 3 4.7 0.9 7.2 2.3 24 10 23 300 2.9 0 2.8 2.8 12/27/2005 07:30:00 6.8 1.3 10.7 3.8 6.1 1.2 9.9 3.4 5.2 1.2 8.4 1.9 26 11 22 300 3 0 3.3 2.8 12/27/2005 07:40:00 5.3 1.7 9.1 1.9 4.9 1.5 8.4 1.5 4.2 1.3 8.8 1.5 40 22 19 300 3.1 0 3.3 2.8 12/27/2005 07:50:00 2.4 1 5.7 0.4 2.4 1 5.7 0.4 2.3 0.7 4.6 0.7 125 53 69 300 0.2 1.4 2.8 -1.9 12/27/2005 08:00:00 2.3 1 4.9 0.4 2.3 0.9 4.6 0.4 1.4 0.5 3.4 0.4 68 33 59 300 -2 0 -1.9 -2.1 12/27/2005 08:10:00 2 1 4.9 0.4 2 1 4.9 0.4 1.5 0.7 3.8 0.4 68 35 17 300 -2 0 -1.9 -2.1 12/27/2005 08:20:00 1.5 0.7 3.4 0.4 1.6 0.7 3.4 0.4 1 0.6 2.6 0.4 71 29 67 300 -2 0 -1.9 -2.1 12/27/2005 08:30:00 1.1 0.5 2.3 0.4 1.1 0.5 2.3 0.4 1.7 0.6 2.6 0.4 175 41 128 300 -2.2 0.1 -2.1 -2.6 12/27/2005 08:40:00 0.6 0.6 3.4 0.4 0.6 0.5 3 0.4 1.3 0.5 2.6 0.4 255 72 8 300 -2.5 0 -2.4 -2.6 12/27/2005 08:50:00 0.9 0.5 2.6 0.4 1 0.6 3 0.4 1.1 0.5 2.6 0.4 116 64 44 300 -2.5 0 -2.4 -2.6 12/27/2005 09:00:00 1.4 0.7 3.4 0.4 1.4 0.7 3.8 0.4 1.2 0.5 3 0.4 105 30 52 300 -2.6 0 -2.6 -2.6 12/27/2005 09:10:00 2.1 0.5 4.2 0.7 2.2 0.4 4.2 0.7 2 0.4 3 0.7 141 41 67 300 -2.6 0 -2.6 -2.8 12/27/2005 09:20:00 1.8 0.7 3.4 0.4 2.1 0.8 3.4 0.4 2.2 0.5 3.4 1.1 215 21 219 300 -2.6 0 -2.6 -2.8 12/27/2005 09:30:00 1.2 0.8 4.6 0.4 1.2 0.8 4.6 0.4 0.9 0.5 2.3 0.4 93 79 89 300 -2.8 0 -2.6 -2.8 12/27/2005 09:40:00 1.9 0.5 3.4 0.7 2 0.5 3.4 0.7 1.4 0.4 2.6 0.4 75 23 59 300 -2.8 0 -2.6 -2.8 12/27/2005 09:50:00 0.9 0.5 2.3 0.4 1 0.5 2.3 0.4 1.8 0.3 2.6 0.7 150 29 121 300 -2.8 0 -2.6 -3 12/27/2005 10:00:00 1.3 0.7 3.4 0.4 1.6 0.7 3.4 0.4 1.8 0.6 2.6 0.4 188 58 25 300 -2.9 0 -2.6 -3 12/27/2005 10:10:00 0.5 0.3 1.9 0.4 0.6 0.4 1.9 0.4 1.4 0.4 2.6 0.4 243 76 339 300 -2.8 0 -2.6 -2.8 12/27/2005 10:20:00 0.7 0.5 2.3 0.4 0.8 0.6 2.6 0.4 0.8 0.5 2.3 0.4 135 86 62 300 -3 0.1 -2.8 -3.3 12/27/2005 10:30:00 2.2 0.8 3.8 0.4 2.3 0.8 4.6 0.7 2 1 3.8 0.4 116 51 67 300 -3.1 0 -2.8 -3.3 12/27/2005 10:40:00 2.8 0.7 4.6 0.4 3.3 0.7 4.6 0.7 3.3 0.7 4.9 1.1 205 16 198 300 -3 0 -2.8 -3.3 12/27/2005 10:50:00 2.6 0.8 4.9 1.1 3 0.8 5.7 1.5 3 0.9 5.3 0.4 213 12 216 300 -2.9 0 -2.8 -3 12/27/2005 11:00:00 1.9 0.8 3.4 0.4 2.2 0.9 3.8 0.4 2.2 0.7 3.8 0.4 185 56 205 300 -2.7 0 -2.6 -2.8 12/27/2005 11:10:00 1.7 0.5 3 0.4 1.9 0.5 3 0.4 2 0.4 3 1.1 181 38 184 300 -2.6 0 -2.6 -2.8 12/27/2005 11:20:00 1.8 0.5 4.2 0.7 2 0.5 3.8 0.7 2 0.4 3 0.7 151 24 103 300 -2.9 0 -2.6 -3 12/27/2005 11:30:00 0.9 0.6 2.3 0.4 1 0.7 2.6 0.4 0.9 0.6 1.9 0.4 85 26 108 300 -3 0 -2.8 -3 12/27/2005 11:40:00 1.5 0.6 3 0.4 1.7 0.5 3 0.4 0.8 0.4 1.9 0.4 51 10 39 300 -3 0 -2.8 -3 12/27/2005 11:50:00 2.5 0.4 3.8 1.5 2.7 0.4 4.2 1.5 1.9 0.5 3 0.7 73 13 70 300 -2.7 0 -2.6 -2.8 12/27/2005 12:00:00 2.1 0.6 3.8 0.7 2.2 0.6 3.4 0.7 1.4 0.7 3 0.4 90 13 107 300 -2.6 0 -2.6 -2.6 12/27/2005 12:10:00 0.7 0.3 1.5 0.4 0.9 0.3 1.9 0.4 1.1 0.3 1.9 0.4 111 17 98 300 -2.6 0 -2.6 -2.8 12/27/2005 12:20:00 0.7 0.4 1.5 0.4 0.9 0.4 1.5 0.4 0.9 0.5 1.9 0.4 147 22 161 300 -2.9 0.1 -2.6 -3 12/27/2005 12:30:00 1.2 0.3 1.9 0.4 1.4 0.2 1.9 0.7 1.3 0.4 2.3 0.4 182 3 184 300 -3.1 0 -3 -3.3 12/27/2005 12:40:00 0.4 0.2 1.5 0.4 0.6 0.4 1.9 0.4 0.4 0.2 1.1 0.4 202 7 206 300 -3.4 0 -3.3 -3.5 12/27/2005 12:50:00 0.9 0.4 1.9 0.4 1 0.5 1.9 0.4 1.1 0.3 1.9 0.4 173 12 181 300 -3.4 0 -3.3 -3.5 12/27/2005 13:00:00 0.4 0.2 1.9 0.4 0.4 0.3 1.9 0.4 1 0.5 2.3 0.4 148 47 45 300 -3.3 0.1 -3 -3.5 12/27/2005 13:10:00 0.8 0.4 1.9 0.4 0.9 0.4 1.9 0.4 1.5 0.4 2.3 0.4 66 22 45 300 -3 0 -2.8 -3.3 12/27/2005 13:20:00 1.4 0.3 1.9 0.7 1.5 0.3 2.3 1.1 1.7 0.3 2.3 1.1 62 9 77 300 -2.8 0 -2.6 -2.8 12/27/2005 13:30:00 2.4 0.3 3 1.5 2.5 0.3 3 1.9 2.4 0.3 3 1.5 47 3 47 300 -2.6 0 -2.6 -2.8 12/27/2005 13:40:00 1.8 0.4 2.6 0.7 1.9 0.4 3 0.7 2 0.3 2.6 1.1 59 13 46 300 -2.6 0 -2.6 -2.6 12/27/2005 13:50:00 1.3 0.4 2.3 0.4 1.5 0.4 2.3 0.7 1.6 0.4 2.3 0.7 83 20 92 300 -2.5 0 -2.4 -2.6 12/27/2005 14:00:00 1 0.3 1.5 0.4 1.2 0.3 1.9 0.4 1 0.4 1.9 0.4 90 11 85 300 -2.5 0 -2.4 -2.8 12/27/2005 14:10:00 0.6 0.3 1.5 0.4 0.8 0.4 1.9 0.4 1.1 0.3 1.9 0.4 89 10 66 300 -2.5 0 -2.4 -2.6 12/27/2005 14:20:00 1.6 0.4 2.3 0.7 1.8 0.4 2.6 0.7 2 0.3 2.6 1.5 54 11 44 300 -2.3 0.1 -2.1 -2.6 12/27/2005 14:30:00 1.9 0.3 2.6 1.5 2 0.3 2.6 1.5 1.6 0.3 2.3 1.1 90 15 109 300 -2.4 0.1 -2.1 -2.6 12/27/2005 14:40:00 1.5 0.4 2.6 0.4 1.7 0.4 2.6 0.7 1.2 0.5 2.3 0.4 90 11 87 300 -2.1 0 -2.1 -2.1 12/27/2005 14:50:00 1.2 0.4 2.3 0.4 1.4 0.4 2.3 0.4 1.1 0.4 1.9 0.4 93 17 59 300 -2.3 0 -2.1 -2.6 12/27/2005 15:00:00 1.1 0.3 1.9 0.4 1.3 0.3 2.3 0.4 0.8 0.3 1.5 0.4 79 17 59 300 -2.4 0 -2.4 -2.6 12/27/2005 15:10:00 1.5 0.5 2.6 0.4 1.7 0.5 3 0.7 1.1 0.4 2.3 0.4 81 17 84 300 -2.5 0 -2.4 -2.6 12/27/2005 15:20:00 1.1 0.4 1.9 0.4 1.4 0.4 2.3 0.4 0.7 0.4 1.5 0.4 87 13 98 300 -2.6 0 -2.6 -2.6 12/27/2005 15:30:00 1.9 0.6 3.4 0.7 2.1 0.6 3.4 1.1 1.3 0.5 2.6 0.4 94 6 98 300 -2.6 0 -2.4 -2.8 12/27/2005 15:40:00 2 0.6 3.4 0.7 2.2 0.6 3.8 0.7 1.4 0.5 2.6 0.4 109 17 100 300 -2.3 0 -2.1 -2.6 12/27/2005 15:50:00 1.8 0.5 3 0.4 2 0.5 3 0.7 1.1 0.4 2.3 0.4 119 10 125 300 -2.4 0 -2.1 -2.6 12/27/2005 16:00:00 1.5 0.5 2.6 0.4 1.7 0.4 2.6 0.7 0.8 0.4 1.5 0.4 113 10 116 300 -2.6 0 -2.6 -2.8 12/27/2005 16:10:00 2.4 0.7 3.8 1.1 2.5 0.6 3.8 1.1 1.3 0.8 2.6 0.4 78 22 48 300 -2.5 0 -2.4 -2.6 12/27/2005 16:20:00 4.1 0.6 6.1 2.6 4.2 0.6 6.5 2.6 3.2 0.6 4.9 1.5 55 7 54 300 -2.4 0 -2.1 -2.6 12/27/2005 16:30:00 4.1 0.4 4.9 3 4.2 0.4 5.3 3.4 3.3 0.5 4.6 1.9 66 7 63 300 -2.1 0.3 -1.4 -2.6 12/27/2005 16:40:00 4 0.6 6.1 1.9 4.1 0.5 6.5 2.3 3.2 0.6 5.3 1.5 64 9 49 300 -1.4 0.3 -0.7 -1.9 12/27/2005 16:50:00 4 0.8 6.5 1.9 4 0.9 6.8 1.9 3.1 0.8 5.7 0.7 53 17 39 300 0.1 0.6 1.4 -0.7 12/27/2005 17:00:00 4.7 1.8 9.9 1.1 4.6 1.7 9.9 1.1 3.8 1.7 8.8 0.4 52 28 39 300 1.8 0.7 3 0.9 12/27/2005 17:10:00 3.3 1.8 9.5 0.4 3.2 1.8 9.9 0.4 2.7 1.4 8.4 0.7 72 61 43 300 0.3 1.5 2.8 -1.7 12/27/2005 17:20:00 2.7 0.7 4.2 0.4 2.8 0.7 4.6 1.1 2.9 0.6 4.9 1.5 130 32 112 300 -2.4 0.2 -1.4 -2.6 12/27/2005 17:30:00 3.2 0.9 7.2 0.7 3.2 0.9 7.6 1.1 3.1 0.5 4.6 1.9 145 22 118 300 -2.7 0 -2.6 -2.8 12/27/2005 17:40:00 2.9 0.8 5.7 0.4 3 0.9 5.3 0.7 3.1 0.5 4.9 1.5 121 28 111 300 -2.8 0 -2.6 -3 12/27/2005 17:50:00 2.6 0.6 4.2 1.1 2.7 0.6 4.2 1.1 2.8 0.6 4.6 1.1 122 23 151 300 -2.6 0 -2.6 -2.8 12/27/2005 18:00:00 2.7 0.7 5.3 1.1 2.8 0.7 4.9 1.5 2.4 0.7 4.2 0.4 99 29 8 300 -2.6 0 -2.6 -2.8 12/27/2005 18:10:00 3 0.7 4.6 1.1 3.2 0.7 4.9 1.1 2.7 0.6 4.6 0.7 106 27 103 300 -3 0 -2.8 -3 12/27/2005 18:20:00 3.5 1.1 7.2 0.7 3.4 1.1 7.2 1.1 2.9 0.7 4.9 0.7 75 38 59 300 -1.4 0.9 -0.5 -3 12/27/2005 18:30:00 3.4 1.5 8 0.7 3.3 1.4 8 0.7 2.4 0.8 6.5 0.4 79 49 48 300 -2 0.3 -1.2 -2.6 12/27/2005 18:40:00 6.8 1.8 11.5 1.9 6.4 1.7 11.5 1.5 5.1 1.5 9.5 1.9 33 18 28 300 2.4 1.6 4.5 -1.2 12/27/2005 18:50:00 4.8 1.9 11.1 1.1 4.6 1.7 11.1 1.5 3.4 1.5 9.1 0.7 60 43 88 300 1.4 2.2 4.5 -1.4 12/27/2005 19:00:00 5.1 2 10.7 0.7 4.8 1.8 11.1 1.1 4 1.6 9.9 0.7 47 35 51 300 -0.1 1.4 2.8 -1.4 12/27/2005 19:10:00 8.4 1.7 13 3 7.7 1.7 12.2 2.6 6.5 1.6 10.7 1.9 25 15 24 300 4.3 0.5 4.8 2.8 12/27/2005 19:20:00 8.5 1.8 12.2 4.2 7.7 1.6 13 3.8 6.2 1.6 11.5 3.4 28 14 45 300 4.8 0 5 4.8 12/27/2005 19:30:00 7.5 1.6 11.1 3 6.8 1.5 10.7 3 5.7 1.5 9.5 2.3 30 13 23 300 4.9 0 5 4.8 12/27/2005 19:40:00 7.2 1.5 10.3 3.8 6.6 1.4 10.3 3.4 5.4 1.3 9.5 2.3 31 14 25 300 5 0 5 5 12/27/2005 19:50:00 6 1.3 9.1 1.9 5.6 1.3 9.1 1.9 4.5 1.2 8.4 1.5 34 16 33 300 4.9 0 5 4.8 12/27/2005 20:00:00 7.7 1.5 11.5 3.8 6.9 1.5 11.1 3 5.9 1.5 9.9 2.3 30 12 17 300 5.1 0 5 5 12/27/2005 20:10:00 7.4 1.3 10.7 4.2 6.8 1.3 10.3 3.4 5.6 1.3 9.9 2.3 34 13 36 300 4.9 0.1 5 4.8 12/27/2005 20:20:00 7.5 1.3 11.5 4.2 7 1.3 10.7 3 5.5 1.3 9.1 2.3 37 13 35 300 4.7 0.1 5 4.5 12/27/2005 20:30:00 8.2 1.7 12.6 4.2 7.5 1.6 11.8 4.2 6.5 1.5 10.7 3 33 13 38 300 4.6 0 4.8 4.5 12/27/2005 20:40:00 8.7 1.7 14.5 4.6 7.8 1.5 12.2 4.2 6.6 1.6 11.1 3 27 13 36 300 4.5 0 4.5 4.5 12/27/2005 20:50:00 8.4 2.2 15.3 4.2 7.9 1.9 13.7 3.8 6.5 1.8 12.6 1.1 33 17 35 300 4.5 0 4.5 4.5 12/27/2005 21:00:00 10.3 1.8 14.9 5.3 9.4 1.7 14.1 4.9 7.9 1.7 12.6 3.8 26 13 30 300 4.5 0 4.5 4.5 12/27/2005 21:10:00 10.1 1.7 15.3 5.7 9.1 1.7 13.7 5.3 7.8 1.9 12.6 2.3 29 12 30 300 4.6 0 4.8 4.5 12/27/2005 21:20:00 9.4 1.7 13.7 5.3 8.5 1.4 13 4.2 7.2 1.5 11.1 3.4 31 12 32 300 4.6 0 4.8 4.5 12/27/2005 21:30:00 10.3 1.7 15.3 5.7 9.3 1.7 15.6 5.3 7.8 1.7 12.2 3.8 27 11 15 300 4.3 0 4.5 4.3 12/27/2005 21:40:00 9.6 1.8 13.3 4.2 8.7 1.7 14.1 3.4 7.2 1.7 11.8 3.4 26 13 28 300 4.1 0 4.5 4 12/27/2005 21:50:00 10.1 1.9 14.9 5.3 9.1 1.7 13.7 5.3 7.7 1.7 11.8 3 27 12 38 300 4 0 4.3 4 12/27/2005 22:00:00 10.2 2 14.9 4.9 9.3 1.9 14.5 4.9 7.8 2 13 3.4 24 13 26 300 4 0 4.3 4 12/27/2005 22:10:00 10.2 2.1 14.9 6.1 9.2 1.9 14.9 4.9 7.7 1.8 14.1 3 26 13 19 300 4 0 4 4 12/27/2005 22:20:00 9.6 2.2 14.5 3.8 8.6 2 13.7 3.4 7.3 2 11.8 2.3 28 13 31 300 4 0 4.3 4 12/27/2005 22:30:00 10.4 1.9 14.5 4.6 9.4 1.7 13.7 4.2 8 1.7 13.7 3.8 28 12 28 300 4 0 4.3 4 12/27/2005 22:40:00 10.1 1.7 14.1 6.5 9.2 1.7 14.1 5.7 7.7 1.7 12.6 3 28 12 27 300 4 0 4.3 4 12/27/2005 22:50:00 10.8 2 16.8 5.7 9.7 1.8 14.5 5.3 8.1 1.7 13.7 3.8 27 12 28 300 4.1 0 4.3 4 12/27/2005 23:00:00 9.4 1.9 14.5 4.9 8.6 1.8 14.1 4.2 7.1 1.7 11.8 3 31 14 16 300 4 0 4.3 3.8 12/27/2005 23:10:00 10.4 1.7 14.5 6.1 9.3 1.6 13.3 5.3 8.1 1.6 12.6 4.2 29 12 21 300 3.7 0.1 4 3.5 12/27/2005 23:20:00 9.2 1.7 13.7 4.2 8.7 1.7 14.5 3.4 7.3 1.8 13.3 2.6 24 17 13 300 3.6 0 3.8 3.5 12/27/2005 23:30:00 9.7 2.2 14.5 4.6 8.8 1.7 14.1 4.2 7.2 1.8 12.6 2.6 28 16 32 300 3.5 0 3.8 3.5 12/27/2005 23:40:00 9.9 1.7 14.1 5.3 8.9 1.5 13 5.3 7.8 1.4 11.8 3.8 29 12 26 300 3.5 0 3.8 3.5 12/27/2005 23:50:00 10 1.7 13.7 5.3 9.1 1.6 14.1 5.3 7.5 1.6 13 3.8 30 12 22 300 3.5 0 3.5 3.5 12/28/2005 00:00:00 9.3 1.4 13.3 4.6 8.5 1.5 12.2 4.2 7.1 1.2 10.7 3.8 31 12 22 300 3.5 0 3.5 3.5 12/28/2005 00:10:00 10.3 1.5 14.5 6.8 9.2 1.4 12.6 5.3 7.6 1.5 11.8 3.8 29 11 13 300 3.6 0 3.8 3.5 12/28/2005 00:20:00 10.3 1.5 14.9 6.5 9.1 1.5 13.3 5.3 7.8 1.5 13 3.8 27 11 49 300 3.7 0 3.8 3.5 12/28/2005 00:30:00 9.6 1.5 13.3 5.7 8.7 1.5 12.6 4.6 7.3 1.5 11.1 4.2 23 11 22 300 4 0 4 3.8 12/28/2005 00:40:00 9.3 1.4 13.3 5.3 8.4 1.5 14.1 4.9 7.2 1.5 11.8 3 24 12 22 300 3.7 0 4 3.5 12/28/2005 00:50:00 9.5 1.5 13.3 5.7 8.6 1.5 12.6 4.9 7.3 1.3 11.8 4.6 27 12 17 300 3.6 0 3.8 3.5 12/28/2005 01:00:00 9 1.5 12.6 5.3 8 1.5 11.5 4.2 6.8 1.4 11.1 3.4 27 11 21 300 3.6 0 3.8 3.5 12/28/2005 01:10:00 8.7 1.5 13 5.3 8 1.5 12.2 4.6 6.8 1.5 11.8 2.6 30 14 16 300 3.6 0 3.8 3.5 12/28/2005 01:20:00 8.3 1.2 11.1 3.8 7.6 1.2 10.7 3.4 6.5 1.3 9.5 3.4 36 11 25 300 3.6 0 3.8 3.5 12/28/2005 01:30:00 8.8 1.5 12.2 4.2 7.9 1.5 12.2 3.8 6.8 1.4 11.1 2.3 27 12 26 300 3.6 0 3.8 3.5 12/28/2005 01:40:00 8.2 1.4 11.5 4.2 7.5 1.5 11.1 3.8 6.3 1.4 10.7 2.6 27 14 10 300 3.4 0 3.5 3.3 12/28/2005 01:50:00 8.2 1.5 12.2 4.2 7.5 1.4 11.1 3.8 6.4 1.3 9.5 3.4 28 15 19 300 3 0.1 3.3 2.8 12/28/2005 02:00:00 10 1.7 14.5 5.7 9 1.7 13.7 4.6 7.5 1.5 12.2 3.8 24 13 48 300 2.9 0 2.8 2.8 12/28/2005 02:10:00 10.6 1.7 14.5 5.7 9.7 1.6 14.5 5.7 8.2 1.6 13 4.6 25 11 31 300 3 0 3.3 2.8 12/28/2005 02:20:00 10 1.7 15.3 3 9 1.7 14.9 3 7.7 1.6 14.5 3.4 28 12 7 300 3 0 3.3 2.8 12/28/2005 02:30:00 10 1.7 13.3 5.7 8.9 1.6 12.6 4.9 7.5 1.6 12.2 3 25 11 24 300 3 0 3.3 2.8 12/28/2005 02:40:00 9.1 1.6 13.3 5.3 8.2 1.5 12.6 4.6 6.9 1.4 11.1 3.4 26 12 21 300 3 0 3.3 2.8 12/28/2005 02:50:00 10.4 1.9 15.3 5.3 9.3 1.6 14.5 4.9 7.9 1.7 12.6 3 26 13 33 300 3 0 3.3 2.8 12/28/2005 03:00:00 9.3 1.3 12.6 4.9 8.3 1.5 12.6 3.8 7.2 1.5 11.5 3 28 12 20 300 3 0 3.3 2.8 12/28/2005 03:10:00 9.2 1.2 13 5.7 8.2 1.3 11.8 5.3 7 1.2 10.7 4.6 28 10 22 300 3 0 3.3 2.8 12/28/2005 03:20:00 10.2 1.7 15.3 5.7 9.2 1.7 14.1 5.3 7.5 1.7 13 3 23 11 22 300 3 0 3.3 2.8 12/28/2005 03:30:00 10.2 1.6 13.7 5.7 9.3 1.6 13.3 4.2 7.7 1.6 13 2.6 29 12 11 300 2.9 0 3 2.8 12/28/2005 03:40:00 10.8 1.7 14.9 6.5 9.7 1.5 12.6 5.7 8.2 1.5 12.2 3.4 26 10 20 300 2.7 0 2.8 2.6 12/28/2005 03:50:00 10.6 1.6 14.1 6.1 9.5 1.5 13.3 4.9 8.1 1.6 12.2 4.9 23 10 19 300 2.7 0 2.8 2.6 12/28/2005 04:00:00 10.9 1.6 15.3 5.7 9.8 1.5 15.3 5.7 8.2 1.6 13.7 4.2 26 12 14 300 2.8 0 2.8 2.6 12/28/2005 04:10:00 10.4 1.6 13.7 4.2 9.3 1.6 14.1 3.8 7.8 1.6 11.5 3.4 26 12 33 300 2.6 0 2.8 2.6 12/28/2005 04:20:00 9.4 1.6 13.3 4.9 8.5 1.6 12.6 4.6 6.9 1.6 11.1 3.4 30 13 11 300 2.7 0 2.8 2.6 12/28/2005 04:30:00 10.4 1.5 14.9 6.1 9.3 1.5 14.5 5.3 7.7 1.5 12.6 3.8 27 11 45 300 2.4 0 2.8 2.3 12/28/2005 04:40:00 11.1 1.7 14.5 6.5 9.7 1.5 13.3 6.1 8 1.6 13.3 3 26 10 26 300 2.1 0 2.3 2.1 12/28/2005 04:50:00 10.8 1.6 14.1 5.3 9.5 1.5 13.7 4.9 7.8 1.6 13 4.2 26 11 20 300 2 0 2.3 1.8 12/28/2005 05:00:00 11.5 1.6 16.1 6.8 10.3 1.5 14.5 6.8 8.6 1.7 13 3.8 25 11 28 300 1.8 0 1.8 1.8 12/28/2005 05:10:00 10.4 1.8 14.5 4.9 9.3 1.6 13.7 4.6 7.7 1.6 12.2 3.4 26 14 31 300 1.8 0 1.8 1.8 12/28/2005 05:20:00 11 1.6 14.1 6.1 9.8 1.5 13.3 5.7 8.3 1.5 12.2 3.8 28 11 24 300 2 0 2.3 1.8 12/28/2005 05:30:00 9.9 1.7 14.5 4.9 9 1.7 13 4.2 7.3 1.7 13.3 3 31 13 36 300 2.3 0 2.3 2.1 12/28/2005 05:40:00 9.5 1.5 13.3 5.3 8.6 1.5 13.7 4.6 7 1.5 11.5 3.4 32 13 49 300 2.6 0 2.8 2.3 12/28/2005 05:50:00 9.5 1.5 13.7 5.3 8.6 1.5 12.6 4.2 7.3 1.5 13 3.4 31 12 26 300 2.6 0.1 2.8 2.3 12/28/2005 06:00:00 10.4 1.5 13.7 5.7 9.1 1.5 12.2 4.6 7.7 1.3 11.8 4.6 28 10 25 300 2.3 0 2.3 2.1 12/28/2005 06:10:00 10.7 1.7 14.5 5.7 9.6 1.7 13.7 4.2 7.9 1.5 12.6 3.4 25 12 24 300 2 0 2.3 1.8 12/28/2005 06:20:00 10.2 1.7 13.7 4.6 9.1 1.5 13 4.2 7.7 1.5 12.2 4.2 27 11 22 300 1.8 0 2.1 1.8 12/28/2005 06:30:00 10.5 1.7 16.1 4.9 9.4 1.7 13.3 4.6 8 1.7 12.6 3.4 25 11 26 300 1.8 0 1.8 1.8 12/28/2005 06:40:00 10.1 1.7 14.1 5.3 9.2 1.7 13.3 4.6 7.7 1.7 12.6 3.8 23 12 31 300 1.9 0 2.1 1.8 12/28/2005 06:50:00 9.3 1.7 13.7 4.9 8.6 1.7 12.6 4.2 7 1.7 11.1 2.6 20 13 34 300 1.8 0 1.8 1.8 12/28/2005 07:00:00 8.7 1.7 12.6 4.6 7.7 1.5 11.1 3.8 6.6 1.5 10.3 2.6 26 13 34 300 1.8 0 1.8 1.8 12/28/2005 07:10:00 9 1.5 12.2 4.6 8.2 1.4 11.8 4.2 6.9 1.3 10.3 2.6 24 13 30 300 1.8 0 2.1 1.8 12/28/2005 07:20:00 8.3 1.7 12.6 3.4 7.5 1.5 11.5 3.4 6.4 1.6 11.1 2.6 29 14 22 300 1.8 0 2.1 1.6 12/28/2005 07:30:00 9.9 1.8 14.5 5.3 9 1.7 13.7 4.9 7.6 1.7 13.3 3 27 13 18 300 1.4 0.1 1.8 1.1 12/28/2005 07:40:00 9.2 1.5 13 5.3 8.3 1.6 13 3.8 7.1 1.6 12.6 3.8 25 13 35 300 0.9 0.1 1.1 0.9 12/28/2005 07:50:00 10.4 1.6 15.3 5.7 9.5 1.7 14.9 4.9 8 1.7 12.2 3.8 21 12 18 300 0.7 0 0.9 0.7 12/28/2005 08:00:00 10 1.5 14.1 5.3 9 1.5 13.3 5.3 7.7 1.5 11.8 3 22 11 34 300 0.8 0.1 0.9 0.7 12/28/2005 08:10:00 9.4 1.9 15.3 4.6 8.6 1.9 14.5 4.2 6.9 1.7 12.6 3.4 21 12 18 300 1.1 0 1.4 0.9 12/28/2005 08:20:00 8.9 1.5 13.7 5.3 8.3 1.5 12.6 4.6 6.9 1.5 12.6 3.4 20 13 348 300 1.2 0 1.4 1.1 12/28/2005 08:30:00 9.8 1.3 13 6.1 9 1.4 13.7 5.7 7.7 1.4 11.1 4.6 21 12 32 300 1.2 0 1.4 1.1 12/28/2005 08:40:00 10.6 1.5 14.9 6.8 9.7 1.5 14.9 5.7 8.2 1.5 13 4.9 21 11 39 300 1.1 0 1.4 0.9 12/28/2005 08:50:00 9.6 1.7 14.1 4.9 8.8 1.7 14.1 4.2 7.6 1.7 13 3.4 23 13 8 300 0.8 0 0.9 0.7 12/28/2005 09:00:00 9.8 1.8 14.1 5.3 8.9 1.7 13 4.6 7.5 1.7 13.3 3.4 22 14 36 300 0.8 0 0.9 0.7 12/28/2005 09:10:00 10 1.6 14.9 5.3 9.2 1.6 14.1 5.3 7.8 1.7 12.6 3.4 21 12 28 300 0.9 0 0.9 0.9 12/28/2005 09:20:00 9.2 1.7 14.5 5.3 8.4 1.7 13.3 4.2 7.1 1.6 13.7 3.4 21 13 18 300 1.1 0 1.4 0.9 12/28/2005 09:30:00 9.8 1.5 14.5 5.7 9.1 1.5 13.7 5.3 7.8 1.7 13.7 3.4 19 12 20 300 1.2 0 1.4 1.1 12/28/2005 09:40:00 9.1 1.5 13 4.2 8.4 1.6 13 4.2 7 1.5 11.1 3 20 13 19 300 1.2 0 1.4 1.1 12/28/2005 09:50:00 8.1 1.8 12.6 3.8 7.4 1.7 12.2 3 6.3 1.5 11.1 2.6 25 15 26 300 1.4 0 1.6 1.4 12/28/2005 10:00:00 8.7 1.4 12.2 4.9 7.9 1.3 11.5 3.8 6.7 1.5 10.7 3.4 29 12 14 300 1.2 0 1.4 0.9 12/28/2005 10:10:00 9.4 1.9 14.5 5.3 8.5 1.7 13 4.6 7.3 1.7 11.8 3 24 12 31 300 1.2 0 1.4 1.1 12/28/2005 10:20:00 9.5 1.7 13.3 3.4 8.7 1.7 13.3 3.4 7.5 1.7 13.3 2.6 22 12 23 300 1.1 0 1.4 0.9 12/28/2005 10:30:00 9.2 1.8 13.3 4.6 8.4 1.7 13 4.6 7 1.5 12.6 1.9 24 12 34 300 1.1 0 1.4 0.9 12/28/2005 10:40:00 9.9 1.7 14.9 5.7 9 1.7 13.3 5.3 7.7 1.7 14.1 3.8 22 12 25 300 1.2 0 1.4 1.1 12/28/2005 10:50:00 9.4 2 14.5 4.6 8.6 2 15.3 3.8 7.5 1.8 12.6 3 25 12 6 300 1.4 0 1.6 1.4 12/28/2005 11:00:00 8.7 1.6 12.6 4.6 8.2 1.7 12.2 4.9 6.9 1.7 12.6 3.4 32 15 31 300 1.5 0 1.6 1.4 12/28/2005 11:10:00 8.8 1.9 13.3 3.8 8.2 1.9 13 3.4 6.9 2 12.2 2.3 33 14 31 300 1.7 0 1.8 1.6 12/28/2005 11:20:00 8.8 1.7 13 3.8 8.1 1.7 13 3.8 6.7 1.6 11.8 2.6 30 15 33 300 1.8 0 2.1 1.6 12/28/2005 11:30:00 8.8 1.7 13 4.6 8.1 1.7 13 4.2 6.8 1.7 12.2 3 33 15 42 300 2.2 0 2.6 2.1 12/28/2005 11:40:00 8.9 1.7 13.3 4.2 8.6 1.7 12.2 4.2 7.1 1.7 12.2 3 41 14 31 300 2.5 0 2.6 2.3 12/28/2005 11:50:00 10.4 2.3 16.1 5.3 10.1 2.3 15.6 4.6 8.4 2.3 14.5 3.4 41 13 60 300 2.8 0.1 3.3 2.6 12/28/2005 12:00:00 10 2 16.4 6.1 9.5 1.9 14.9 4.9 7.8 1.9 13 3.4 35 13 36 300 2.9 0 3.3 2.8 12/28/2005 12:10:00 8.4 1.7 12.2 3 7.6 1.7 12.2 2.6 6.4 1.5 11.1 3 31 13 5 300 2.9 0 3 2.8 12/28/2005 12:20:00 7.2 1.4 9.9 3.8 6.6 1.3 9.9 3.4 5.8 1.3 9.9 2.6 33 12 18 300 2.9 0 3 2.8 12/28/2005 12:30:00 6.9 1.3 10.3 3.4 6.3 1.2 9.5 3 5.4 1.2 9.9 3 33 13 16 300 2.7 0 2.8 2.6 12/28/2005 12:40:00 7.8 1.5 11.1 3.8 7 1.4 10.7 3 6.1 1.3 10.7 2.6 28 13 28 300 2.8 0 2.8 2.8 12/28/2005 12:50:00 8.6 1.5 13 3.8 7.8 1.4 11.8 3.4 6.6 1.5 10.3 2.3 24 13 19 300 3 0.1 3.3 2.8 12/28/2005 13:00:00 8.5 1.6 13.7 3.4 7.7 1.5 11.8 3.4 6.2 1.6 11.5 1.1 27 13 24 300 3.3 0 3.5 3.3 12/28/2005 13:10:00 8 1.5 11.8 3.8 7.3 1.3 11.1 4.2 6.3 1.4 11.1 3.4 30 13 28 300 3.5 0.1 3.8 3.5 12/28/2005 13:20:00 8.3 1.5 11.8 4.2 7.6 1.5 11.5 3.8 6.6 1.5 11.1 3 27 12 27 300 4 0 4 3.8 12/28/2005 13:30:00 8.8 1.5 13 4.9 8 1.5 11.8 4.2 6.7 1.5 11.1 3.4 29 13 29 300 3.8 0 4 3.8 12/28/2005 13:40:00 9.3 1.6 13.3 4.6 8.6 1.5 12.6 4.6 7 1.5 11.1 2.6 34 12 48 300 4 0 4.3 3.8 12/28/2005 13:50:00 9.3 1.7 13.7 4.6 8.6 1.7 13.3 3.8 7.1 1.6 11.8 3.8 31 13 18 300 3.8 0 3.8 3.5 12/28/2005 14:00:00 9 1.5 13.7 4.9 8.2 1.5 13.3 3.8 7 1.5 12.2 2.3 26 13 41 300 3.6 0.1 3.8 3.3 12/28/2005 14:10:00 9.4 1.3 13 5.7 8.5 1.3 12.2 5.3 7.2 1.3 11.8 3.8 26 11 28 300 3.1 0 3.5 3 12/28/2005 14:20:00 9.7 1.5 13.3 5.3 8.7 1.5 13 5.3 7.3 1.5 11.1 3.4 27 11 26 300 3.2 0 3.3 3 12/28/2005 14:30:00 9 1.7 13.3 4.2 8.1 1.7 12.6 4.2 6.8 1.5 12.2 3.4 30 13 42 300 3.3 0 3.5 3.3 12/28/2005 14:40:00 9.4 1.5 13 5.7 8.5 1.4 13.3 4.6 7.4 1.6 13.3 3.8 31 12 29 300 3.6 0 3.8 3.5 12/28/2005 14:50:00 8 1.5 11.5 3.8 7.3 1.4 11.1 3.8 6.1 1.4 10.7 2.6 29 13 14 300 3.9 0 4 3.8 12/28/2005 15:00:00 7.5 1.4 11.5 3.8 6.8 1.4 11.5 3.4 6 1.3 9.9 2.6 28 12 22 300 4 0 4 3.8 12/28/2005 15:10:00 8.3 1.3 11.5 3.8 7.4 1.3 11.1 3.8 6.4 1.3 10.7 3.4 28 12 31 300 3.9 0 4 3.8 12/28/2005 15:20:00 8.2 1.5 11.1 4.2 7.3 1.4 10.7 3.4 5.9 1.3 9.9 2.6 28 11 25 300 4 0 4 3.8 12/28/2005 15:30:00 6.6 1.5 10.7 2.6 6.1 1.4 9.5 2.3 5.1 1.4 8.8 1.5 32 14 27 300 4 0 4.3 4 12/28/2005 15:40:00 6.2 1.3 9.5 2.3 6 1.4 8.8 1.9 4.8 1.3 8.8 1.5 43 13 35 300 4 0 4.3 4 12/28/2005 15:50:00 8.7 1.5 13 4.9 8.1 1.6 13 4.2 6.9 1.6 11.1 3 36 13 46 300 4.3 0 4.5 4.3 12/28/2005 16:00:00 8 1.5 11.8 3 7.5 1.5 11.8 2.6 6.2 1.6 9.9 2.3 38 13 39 300 4.3 0 4.5 4.3 12/28/2005 16:10:00 8.6 1.5 13 5.3 7.9 1.4 12.6 4.6 6.6 1.4 10.7 3.4 32 11 34 300 4.4 0 4.5 4.3 12/28/2005 16:20:00 8.7 1.3 12.2 5.7 7.8 1.2 11.1 4.9 6.5 1.2 9.5 3.8 30 12 25 300 4.6 0 4.8 4.5 12/28/2005 16:30:00 8.6 1.6 12.2 3.8 7.8 1.4 11.1 3 6.7 1.5 12.6 2.3 29 11 26 300 4.7 0 4.8 4.5 12/28/2005 16:40:00 7.5 1.4 11.5 2.6 6.8 1.3 11.5 2.3 5.8 1.3 9.5 2.3 30 14 16 300 4.8 0 4.8 4.8 12/28/2005 16:50:00 8.4 1.3 12.2 4.9 7.6 1.5 12.6 4.2 6.4 1.4 10.7 3 22 12 14 300 4.6 0 4.8 4.5 12/28/2005 17:00:00 8.9 1.5 12.6 4.9 8.2 1.6 11.8 4.2 6.9 1.3 11.1 3.4 19 10 19 300 4.5 0 4.5 4.5 12/28/2005 17:10:00 9.2 1.5 12.2 4.9 8.2 1.5 12.2 3.8 6.7 1.3 11.1 3.8 21 10 28 300 4.6 0 4.8 4.5 12/28/2005 17:20:00 8.3 1.2 11.5 4.6 7.7 1.3 11.1 3.8 6.3 1.5 9.9 2.6 19 10 20 300 4.6 0 4.8 4.5 12/28/2005 17:30:00 8.5 1.2 11.1 4.9 7.9 1.3 11.1 4.6 6.5 1.3 10.3 3.4 18 10 22 300 4.5 0 4.8 4.5 12/28/2005 17:40:00 7.6 1.6 11.1 3.8 7.3 1.7 11.8 3 6.1 1.6 10.3 2.6 15 12 8 300 4.6 0 4.8 4.5 12/28/2005 17:50:00 6.5 1.3 9.5 3 6.1 1.4 9.1 2.6 5.1 1.3 9.5 1.9 21 13 15 300 4.6 0 4.8 4.3 12/28/2005 18:00:00 6.6 1.8 11.1 2.3 6.1 1.8 11.5 1.9 5.1 1.6 8.8 1.1 27 17 27 300 4.4 0 4.5 4.3 12/28/2005 18:10:00 6.4 1.1 9.1 3.4 6.2 1.1 8.8 2.6 5.2 1.2 8.4 1.5 41 10 31 300 4.3 0 4.5 4.3 12/28/2005 18:20:00 6.5 1 8.8 3.8 6.4 1.1 8.4 3.4 5.1 1.1 8 1.9 43 10 38 300 4.4 0 4.5 4.3 12/28/2005 18:30:00 6.8 1.2 9.9 3.4 6.7 1.2 9.5 3.4 5 1.3 8.8 2.3 48 13 43 300 4.6 0 4.8 4.5 12/28/2005 18:40:00 7.5 1.7 11.5 3.8 6.9 1.5 11.5 3.4 5.8 1.5 10.3 2.6 36 11 26 300 4.6 0 4.8 4.5 12/28/2005 18:50:00 8 1.3 11.5 4.2 7.3 1.3 10.7 3.8 6.2 1.3 10.7 3 34 11 35 300 4.3 0 4.5 4 12/28/2005 19:00:00 8.1 1.3 11.1 3.8 7.3 1.2 10.7 4.2 6.3 1.3 9.9 3 32 11 40 300 4 0 4.3 3.8 12/28/2005 19:10:00 8.7 1.4 11.8 4.9 7.7 1.3 11.8 4.6 6.5 1.3 11.1 3.4 28 11 32 300 3.9 0 4 3.8 12/28/2005 19:20:00 9.3 1.3 12.2 5.3 8.2 1.2 11.8 4.6 6.8 1.2 10.3 3.4 27 10 25 300 3.8 0 4 3.8 12/28/2005 19:30:00 9.6 1.3 13 5.3 8.5 1.3 11.8 4.6 6.9 1.5 11.1 3 26 10 28 300 3.6 0 3.8 3.5 12/28/2005 19:40:00 9.4 1.7 13 3.4 8.2 1.6 12.2 2.6 6.7 1.5 11.1 2.6 24 10 26 300 3.5 0 3.5 3.5 12/28/2005 19:50:00 9.8 1.4 13 4.6 8.6 1.4 12.2 3.8 7.3 1.2 11.1 3.8 28 9 19 300 3.3 0 3.5 3.3 12/28/2005 20:00:00 9.2 1.5 12.6 4.6 8.1 1.5 11.8 4.2 6.8 1.3 11.1 3.4 29 10 18 300 3.3 0 3.5 3.3 12/28/2005 20:10:00 8.9 1.5 13 4.9 8.1 1.5 12.6 3.4 7 1.7 12.2 3 31 11 25 300 3.4 0 3.5 3.3 12/28/2005 20:20:00 9.1 1.3 12.2 5.3 8.3 1.4 11.8 4.9 7 1.4 11.1 3.4 34 11 18 300 3.5 0 3.5 3.5 12/28/2005 20:30:00 9.3 1.5 12.6 3.8 8.4 1.4 12.2 3.8 6.9 1.5 11.1 3 34 20 31 300 3.5 0 3.5 3.5 12/28/2005 20:40:00 9.2 1.3 11.8 5.3 8.3 1.3 12.2 4.2 6.9 1.3 9.9 3 31 10 37 300 3.5 0 3.5 3.5 12/28/2005 20:50:00 8.9 1.5 11.8 4.2 8 1.4 11.5 4.2 6.9 1.5 11.1 3.4 30 13 31 300 3.4 0 3.5 3.3 12/28/2005 21:00:00 9.1 1.5 13.7 4.6 8.1 1.3 11.5 4.6 6.7 1.2 11.8 3.8 31 11 33 300 3.2 0 3.5 3.3 12/28/2005 21:10:00 8.5 1.5 12.2 4.6 7.7 1.4 11.8 4.2 6.4 1.4 10.3 3 31 12 29 300 3.2 0 3.3 3.3 12/28/2005 21:20:00 7.7 1.3 11.8 3.8 7.1 1.3 11.5 3.4 6 1.3 10.7 2.6 31 13 40 300 3.2 0 3.5 3.3 12/28/2005 21:30:00 8.8 1.3 12.6 4.9 7.7 1.2 12.2 4.2 6.5 1.2 10.3 2.6 29 9 22 300 3.4 0 3.5 3.3 12/28/2005 21:40:00 9.1 1.6 13 4.6 7.9 1.5 12.2 4.2 6.5 1.6 11.1 2.6 22 9 24 300 3.5 0 3.5 3.5 12/28/2005 21:50:00 8 1.3 11.1 4.6 7.2 1.3 11.1 4.2 5.9 1.3 10.3 3 30 11 28 300 3.5 0 3.5 3.5 12/28/2005 22:00:00 8.2 1.6 11.1 3.8 7.3 1.5 11.1 3.4 6.1 1.2 9.1 2.6 29 11 17 300 3.5 0 3.5 3.5 12/28/2005 22:10:00 8.2 1.4 10.7 3.8 7.3 1.3 10.3 3.8 6.1 1.3 9.5 1.5 27 11 30 300 3.5 0 3.5 3.5 12/28/2005 22:20:00 7.6 1.4 11.5 4.2 6.9 1.3 10.7 3.4 6 1.3 9.5 2.6 31 13 26 300 3.5 0 3.5 3.5 12/28/2005 22:30:00 8.2 1.3 11.8 4.9 7.3 1.2 11.1 4.2 6.2 1.3 9.9 2.3 29 13 29 300 3.5 0 3.8 3.5 12/28/2005 22:40:00 8 1.3 10.7 3.8 7.2 1.2 11.1 3.8 6.1 1.2 10.3 3 32 12 40 300 3.4 0 3.5 3.5 12/28/2005 22:50:00 8.7 1.4 12.2 4.9 7.9 1.3 11.1 4.6 6.6 1.3 10.3 3 34 11 18 300 3.4 0 3.5 3.5 12/28/2005 23:00:00 8.2 1.3 11.1 3.8 7.3 1.2 10.7 3.4 6.2 1.2 9.5 3 31 10 29 300 3.3 0 3.5 3.3 12/28/2005 23:10:00 8.3 1.3 11.1 4.6 7.4 1.2 10.3 3.8 5.9 1.2 9.1 2.6 30 13 43 300 3.3 0 3.5 3.3 12/28/2005 23:20:00 8 1.5 11.8 4.6 7.3 1.3 10.3 3.4 5.9 1.3 9.1 2.3 29 13 40 300 3.4 0 3.5 3.3 12/28/2005 23:30:00 8 1.5 11.8 3.4 7.1 1.3 10.3 3 6.1 1.2 9.5 3.8 28 12 41 300 3.5 0 3.5 3.5 12/28/2005 23:40:00 8.2 1.5 11.5 4.6 7.4 1.5 11.1 3.4 6.3 1.3 10.3 3.4 26 13 18 300 3.8 0 4 3.5 12/28/2005 23:50:00 8.4 1.5 11.5 4.2 7.5 1.4 11.1 4.2 6.5 1.3 9.9 3 21 12 24 300 4 0 4.3 4 12/29/2005 00:00:00 8.7 1.3 11.8 4.9 7.8 1.3 11.8 4.6 6.5 1.3 10.3 3.4 27 12 16 300 4.3 0 4.5 4.3 12/29/2005 00:10:00 8.7 1.5 12.2 3.8 7.6 1.4 11.1 3.8 6.3 1.3 11.1 3.8 26 10 34 300 4.4 0 4.5 4.3 12/29/2005 00:20:00 8 1.2 10.7 4.6 7.3 1.2 10.7 4.2 6.3 1.2 10.3 3 21 11 14 300 4.4 0 4.5 4.3 12/29/2005 00:30:00 9 1.2 11.8 4.9 8.2 1.3 11.5 4.6 6.8 1.3 10.7 3 21 11 10 300 4.1 0 4.3 4 12/29/2005 00:40:00 8.5 1.4 11.8 4.6 7.7 1.3 12.2 3.8 6.5 1.3 9.5 3 22 13 12 300 4 0 4.3 3.8 12/29/2005 00:50:00 9.3 1.4 12.6 5.7 8.6 1.4 13 5.7 7 1.4 10.7 3.4 22 12 16 300 4 0 4 3.8 12/29/2005 01:00:00 9.5 1.4 13.3 6.1 8.5 1.4 12.2 4.6 7 1.4 11.1 3.4 24 11 20 300 4 0 4 4 12/29/2005 01:10:00 9.2 1.4 12.2 4.9 8.2 1.3 12.2 4.2 7 1.2 10.7 3.8 24 10 27 300 4 0 4 3.8 12/29/2005 01:20:00 10 1.8 14.5 5.3 8.9 1.7 13 4.2 7.5 1.7 12.2 3.4 23 11 21 300 3.6 0.1 4 3.5 12/29/2005 01:30:00 9.9 1.2 12.6 6.1 8.7 1.2 12.2 5.7 7.5 1.3 11.1 3.8 23 10 23 300 3.5 0 3.8 3.5 12/29/2005 01:40:00 9.5 1.5 12.6 5.7 8.6 1.6 13 4.6 7.3 1.4 11.8 4.6 23 12 15 300 3.6 0 3.8 3.5 12/29/2005 01:50:00 9.2 1.7 13.3 4.2 8.4 1.7 13 3.8 7.1 1.7 11.8 2.3 25 13 23 300 3.8 0 4 3.8 12/29/2005 02:00:00 9.6 1.7 13.7 4.2 8.7 1.8 14.1 3.8 7.4 1.7 12.6 4.2 23 12 19 300 4 0 4.3 3.8 12/29/2005 02:10:00 9.8 1.6 13.3 4.9 8.6 1.4 12.2 4.2 7.3 1.3 10.3 4.2 25 11 17 300 4.1 0 4.3 4 12/29/2005 02:20:00 9.6 1.4 12.2 5.7 8.5 1.4 12.6 4.6 7.1 1.2 11.1 4.2 26 10 21 300 4.3 0 4.5 4.3 12/29/2005 02:30:00 8.9 1.5 11.8 4.2 7.8 1.3 11.1 3.4 6.5 1.4 10.3 3 25 11 18 300 4.3 0 4.5 4.3 12/29/2005 02:40:00 8.8 1.3 12.2 4.6 7.9 1.3 11.5 4.2 6.6 1.3 10.7 1.9 27 12 21 300 4.2 0 4.3 4 12/29/2005 02:50:00 8.7 1.3 11.5 3.8 7.6 1.2 11.1 3.8 6.5 1.3 10.3 3.4 26 10 38 300 4.2 0 4.3 4.3 12/29/2005 03:00:00 8.6 1.2 11.5 5.3 7.5 1.2 10.7 4.2 6.4 1.2 10.7 3.8 27 10 29 300 4.3 0 4.5 4.3 12/29/2005 03:10:00 9.4 1.5 12.2 5.3 8.2 1.3 10.7 4.6 6.8 1.3 10.3 3.8 27 9 34 300 4.1 0 4.3 4 12/29/2005 03:20:00 8.6 1.4 12.2 5.3 7.7 1.3 11.8 4.6 6.5 1.3 10.3 3.4 31 11 36 300 4 0 4 3.8 12/29/2005 03:30:00 8.5 1.3 11.8 4.6 7.8 1.2 11.1 4.6 6.4 1.3 10.7 3.4 32 11 32 300 4 0 4.3 3.8 12/29/2005 03:40:00 8.3 1.4 12.6 4.6 7.4 1.3 10.7 4.2 6.1 1.2 9.1 3.4 26 10 31 300 4 0 4.3 3.8 12/29/2005 03:50:00 7.4 1.3 11.1 3 6.8 1.3 10.3 3.4 5.8 1.2 8.8 3 23 14 33 300 4 0 4.3 3.8 12/29/2005 04:00:00 8.2 1.3 11.8 4.9 7.3 1.2 11.1 4.2 6.1 1.1 8.8 2.6 27 11 37 300 3.8 0 4 3.8 12/29/2005 04:10:00 8.8 1.3 11.8 4.9 7.8 1.2 10.7 4.2 6.6 1.3 11.5 3 27 10 42 300 3.8 0 4 3.8 12/29/2005 04:20:00 8.9 1.5 12.2 4.2 7.9 1.3 11.8 4.6 6.6 1.1 9.1 3.4 27 11 35 300 3.8 0 4 3.8 12/29/2005 04:30:00 7.2 1.4 11.1 3.8 6.6 1.3 9.5 2.6 5.3 1.1 8.4 3 29 13 39 300 4 0 4 3.8 12/29/2005 04:40:00 6.9 1.4 11.5 2.6 6.4 1.3 10.3 3 5.3 1.2 9.1 2.3 33 16 16 300 4 0 4 4 12/29/2005 04:50:00 7.9 1.6 11.8 4.2 7.2 1.5 11.5 4.2 5.9 1.5 11.1 2.3 27 13 32 300 4 0 4.3 3.8 12/29/2005 05:00:00 9.4 1.3 12.2 4.6 8.6 1.4 12.2 3.8 7.3 1.5 11.8 3.8 20 10 19 300 4 0 4.3 3.8 12/29/2005 05:10:00 8.1 1.5 10.7 3.8 7.5 1.5 11.5 3.4 6.1 1.6 10.3 2.6 20 13 12 300 3.5 0.1 3.8 3.3 12/29/2005 05:20:00 5.9 1.5 9.9 1.9 5.5 1.4 9.5 1.5 4.5 1.1 8 2.3 24 15 21 300 3.2 0 3.5 3.3 12/29/2005 05:30:00 6.5 1.2 9.1 3.4 6.3 1.3 9.9 3.4 5.3 1.2 9.5 2.3 15 13 14 300 3.3 0 3.5 3.3 12/29/2005 05:40:00 6.7 1.3 9.9 3 6.7 1.5 10.3 3.4 5.4 1.3 8.4 2.6 12 13 9 300 3.3 0 3.5 3.3 12/29/2005 05:50:00 7.3 1.3 10.7 3.8 7.3 1.5 11.1 3 5.8 1.5 9.5 3 9 11 344 300 3.4 0 3.5 3.3 12/29/2005 06:00:00 7.7 1.1 10.7 4.9 7.6 1.3 11.1 4.2 6.2 1.4 10.3 3 14 10 22 300 3.6 0 3.8 3.5 12/29/2005 06:10:00 6.8 1.3 9.5 3 6.5 1.4 10.3 2.6 5.3 1.3 8.8 1.9 17 13 9 300 3.5 0 3.8 3.3 12/29/2005 06:20:00 7.3 1.3 11.1 3.4 7 1.4 11.1 3.4 5.8 1.3 9.1 2.6 16 12 23 300 3.5 0 3.5 3.3 12/29/2005 06:30:00 8 1.3 11.1 3.8 7.3 1.3 10.7 4.2 6 1.1 10.3 3.4 23 13 8 300 3.6 0 3.8 3.5 12/29/2005 06:40:00 7.7 1.2 10.7 3.8 7 1.3 10.7 3.8 5.7 1.3 9.5 2.3 22 11 17 300 3.7 0 3.8 3.5 12/29/2005 06:50:00 7.8 1.2 10.7 4.9 6.9 1.1 10.3 4.2 5.6 1 8 3 23 10 30 300 3.8 0 4 3.5 12/29/2005 07:00:00 7.4 1.2 10.7 3.8 6.6 1.1 9.9 3.4 5.6 1 8.4 2.3 28 10 25 300 3.8 0 4 3.8 12/29/2005 07:10:00 7.5 1.5 11.5 4.2 7 1.6 11.8 3.8 5.7 1.3 9.9 3 34 13 36 300 4.2 0.2 4.5 4 12/29/2005 07:20:00 8.5 1.7 13.3 4.2 7.8 1.6 12.6 3.4 6.3 1.4 10.3 2.6 32 12 34 300 4.5 0 4.5 4.5 12/29/2005 07:30:00 8.3 1.3 11.1 4.6 7.5 1.3 10.7 3.4 6.2 1.3 9.9 2.6 29 12 22 300 4.4 0 4.5 4.3 12/29/2005 07:40:00 8.3 1.5 11.8 4.9 7.4 1.5 11.5 3.8 6.2 1.3 9.5 3 26 11 27 300 4.2 0 4.5 4 12/29/2005 07:50:00 7.3 1.2 9.9 4.2 6.6 1.2 9.5 3.8 5.7 1.2 8.8 2.6 27 11 38 300 4.3 0 4.5 4.3 12/29/2005 08:00:00 6.8 1.3 10.7 3.4 6.3 1.2 9.1 3.8 5.3 1.2 8.8 2.3 28 13 18 300 4.3 0 4.5 4.3 12/29/2005 08:10:00 7.4 1.2 10.7 3.4 6.8 1.2 9.9 3 5.7 1.2 9.1 2.6 32 11 21 300 4.5 0 4.8 4.3 12/29/2005 08:20:00 7.4 1.2 10.3 4.2 7 1.2 9.9 3.8 5.6 1.3 9.1 2.6 36 12 31 300 4.6 0 4.8 4.5 12/29/2005 08:30:00 7.6 1.5 11.1 3 7.1 1.3 11.1 3 6.1 1.4 9.1 2.3 30 14 16 300 4.1 0.2 4.5 3.8 12/29/2005 08:40:00 7.6 1.4 10.7 3.4 6.9 1.3 9.9 3 5.8 1.3 10.3 3 25 15 31 300 3.5 0 3.8 3.3 12/29/2005 08:50:00 8.9 1.5 12.6 4.6 7.9 1.3 11.8 4.2 6.7 1.4 11.8 2.6 22 11 24 300 3.3 0 3.5 3.3 12/29/2005 09:00:00 9.2 1.7 12.6 4.9 8.1 1.5 12.2 4.6 6.9 1.3 11.5 3.4 28 11 27 300 3.2 0 3.5 3 12/29/2005 09:10:00 9.4 1 11.8 6.5 8.9 1.2 11.8 5.3 6.9 1.3 10.7 3.4 37 8 52 300 3.1 0 3.3 3 12/29/2005 09:20:00 8.8 1.8 13 3.4 8.5 1.9 13 3 6.3 1.9 11.1 1.9 40 13 54 300 3.8 0.2 4.3 3.3 12/29/2005 09:30:00 7.6 1.1 10.3 4.2 7.3 1.3 9.9 3.4 5.5 1.2 8.4 1.9 40 11 36 300 4 0 4 4 12/29/2005 09:40:00 7.6 1.3 10.7 3.8 6.8 1.2 10.3 3 5.3 1.2 8.8 2.6 33 12 26 300 3.8 0.2 4 3.5 12/29/2005 09:50:00 6.6 1.1 9.1 3.4 6.1 1.1 9.1 3 5 1.1 8 2.3 35 11 32 300 3.4 0 3.5 3.3 12/29/2005 10:00:00 8 1.5 11.5 4.2 7.1 1.3 9.9 3.4 5.7 1.3 8.8 2.3 31 10 22 300 3.5 0 3.5 3.3 12/29/2005 10:10:00 9.1 1.3 11.8 4.6 7.8 1.2 11.5 3.8 6.3 1.2 9.1 2.6 28 9 29 300 3.4 0 3.5 3.3 12/29/2005 10:20:00 8 1.5 11.1 4.6 7.1 1.3 10.3 3.8 5.7 1.3 10.3 3 30 12 29 300 3.5 0 3.5 3.5 12/29/2005 10:30:00 8.2 1.3 11.1 3.4 7.3 1.3 10.7 2.6 5.9 1.2 9.1 3 32 11 27 300 3.8 0.1 4 3.5 12/29/2005 10:40:00 7.6 1.1 10.7 4.6 6.9 1 9.5 4.2 5.7 1 8.8 3 31 11 28 300 3.9 0 4 3.8 12/29/2005 10:50:00 7.9 1 11.1 4.2 7.2 1.1 10.7 3.4 5.9 1.1 8.8 3 34 10 35 300 3.6 0 3.8 3.5 12/29/2005 11:00:00 7.9 1.1 11.5 4.6 7.5 1.2 10.7 4.6 6 1.2 9.5 3 38 9 29 300 3.9 0 4.3 3.8 12/29/2005 11:10:00 8.1 1.2 10.7 4.9 7.5 1.2 10.3 4.6 5.9 1.3 9.1 2.3 34 11 56 300 4.3 0.1 4.5 4 12/29/2005 11:20:00 7.7 1.3 11.1 3.4 6.7 1.2 10.7 3.4 5.6 1.4 9.9 1.1 29 11 30 300 4.3 0 4.5 4.3 12/29/2005 11:30:00 6.9 1.4 10.7 3 6.3 1.5 9.9 2.3 5.1 1.3 8.4 1.9 34 12 33 300 4.3 0 4.5 4.3 12/29/2005 11:40:00 6.9 1.2 9.9 3.4 6.2 1.2 9.5 3 5.2 1.1 8 1.9 31 12 45 300 4.1 0 4.5 4 12/29/2005 11:50:00 6.3 1.4 9.1 2.3 5.7 1.2 8.8 2.3 4.9 1.1 7.6 2.6 32 15 22 300 3.8 0.1 4 3.5 12/29/2005 12:00:00 4.9 1.7 9.1 1.5 4.6 1.6 9.5 1.5 3.7 1.4 7.2 0.4 36 17 39 300 3.6 0 3.8 3.5 12/29/2005 12:10:00 6 1.1 9.9 3.4 5.7 1.1 8.4 3 4.9 1.1 8.8 2.3 36 12 19 300 3.6 0 3.8 3.5 12/29/2005 12:20:00 6.5 1.1 9.9 3.8 6 1.1 9.5 3.4 5.1 1 8.4 2.6 31 10 16 300 3.6 0 3.8 3.5 12/29/2005 12:30:00 7.6 1.3 10.7 3.4 6.8 1.2 9.9 3.8 5.7 1.1 9.5 3 23 11 22 300 3.8 0 3.8 3.5 12/29/2005 12:40:00 7.9 1.3 11.5 4.6 7.1 1.2 9.9 4.2 5.8 1.3 9.1 1.9 26 13 29 300 3.8 0 4 3.8 12/29/2005 12:50:00 7.8 1.4 11.1 4.6 6.9 1.3 10.3 3.8 5.9 1.2 10.3 3.4 27 11 9 300 4 0 4 3.8 12/29/2005 13:00:00 8.1 1.2 11.1 4.6 7.1 1.1 9.9 3.8 6 1.1 9.9 3.4 24 9 31 300 4.1 0 4.5 4 12/29/2005 13:10:00 6.5 1.3 9.9 3.4 6.2 1.4 10.3 3 5.3 1.2 8.8 2.6 19 13 10 300 3.8 0 4 3.8 12/29/2005 13:20:00 7.1 1.4 10.3 4.2 6.5 1.3 10.3 3.8 5.3 1.2 9.1 2.3 29 13 12 300 3.8 0 3.8 3.8 12/29/2005 13:30:00 7.1 1.5 10.3 3.8 6.3 1.3 10.7 3.4 5.3 1.3 8.8 2.3 28 14 14 300 3.8 0 4 3.8 12/29/2005 13:40:00 6.8 1.5 10.7 3.4 6.3 1.5 10.7 2.6 5.2 1.3 8.8 2.3 24 15 16 300 3.5 0 3.8 3.3 12/29/2005 13:50:00 7.5 1.4 11.1 4.2 7.3 1.5 11.5 3.8 6.2 1.4 11.1 3 14 11 14 300 3.3 0 3.5 3.3 12/29/2005 14:00:00 7.2 1.3 11.5 3.8 7 1.5 12.2 3.8 5.7 1.5 9.5 1.9 13 13 10 300 3.3 0 3.5 3.3 12/29/2005 14:10:00 6.8 1.3 10.7 3.4 6.5 1.4 11.1 3.4 5.2 1.2 9.1 2.3 17 13 7 300 3.2 0 3.5 3.3 12/29/2005 14:20:00 7.5 1.5 10.7 3.8 7 1.7 11.1 3 5.9 1.7 10.3 2.3 20 12 2 300 3.3 0 3.5 3.3 12/29/2005 14:30:00 6.5 1.2 9.9 3.4 6.1 1.3 9.9 3 5 1.1 8.8 2.3 25 13 359 300 3.5 0 3.5 3.5 12/29/2005 14:40:00 6.2 1.3 9.1 2.6 5.6 1.2 8.4 2.6 4.6 1.2 8 2.3 31 15 31 300 3.6 0 3.8 3.5 12/29/2005 14:50:00 7.9 1.5 11.8 4.2 7.1 1.4 11.1 3.4 5.4 1.5 9.1 1.9 32 12 27 300 4.3 0 4.5 3.8 12/29/2005 15:00:00 7.6 1.5 11.5 3 6.9 1.4 11.1 3 5.2 1.6 11.5 1.1 35 17 27 300 4.1 0.1 4.5 4 12/29/2005 15:10:00 6.6 1.5 10.3 2.3 6.4 1.5 10.3 2.3 4.9 1.5 9.1 1.9 43 15 31 300 3.9 0 4 3.8 12/29/2005 15:20:00 7.5 1.6 11.8 2.3 7.5 1.6 11.5 2.3 5.7 1.6 9.9 2.3 53 18 65 300 5 0.7 6 3.8 12/29/2005 15:30:00 7.5 1.7 11.8 3 7.4 1.7 11.8 3.4 5.6 1.8 11.1 1.9 49 15 66 300 6.1 0 6.2 6 12/29/2005 15:40:00 8.1 2.1 15.3 2.3 8 2.2 15.3 2.6 6.2 1.9 12.6 1.9 51 20 97 300 6.4 0 6.7 6.2 12/29/2005 15:50:00 8 2.1 13.7 1.9 8.1 2.1 13 1.9 6.6 2 11.8 2.3 58 19 70 300 6.6 0 6.7 6.2 12/29/2005 16:00:00 8.1 1.7 13 2.3 8.2 1.7 13 2.3 6.6 1.9 11.8 2.6 59 13 66 300 6.2 0 6.5 6 12/29/2005 16:10:00 7.9 1.5 14.1 4.2 8 1.5 14.5 4.6 6.2 1.6 11.1 3 58 13 75 300 6.4 0.1 6.7 6.2 12/29/2005 16:20:00 6.4 1.3 9.5 3 5.8 1.1 8.4 2.6 4.6 1.1 8 1.9 32 14 23 300 4.9 1 6.2 3.5 12/29/2005 16:30:00 6.4 1.3 9.5 1.5 5.9 1.3 8.8 2.3 4.6 1.2 7.6 1.5 30 17 23 300 3 0.2 3.5 2.8 12/29/2005 16:40:00 6.9 1.3 9.9 3.4 6.3 1.3 9.5 2.6 4.8 1.2 8 1.9 33 13 31 300 3.2 0 3.5 3 12/29/2005 16:50:00 7.5 1.4 10.7 3 7.2 1.5 10.7 3.4 5.3 1.3 9.1 2.3 40 11 53 300 3.8 0.4 4.8 3.3 12/29/2005 17:00:00 7 1.6 11.5 3 7.1 1.6 11.5 3 5.2 1.5 9.9 1.9 59 16 69 300 5.4 0.5 6.2 4.5 12/29/2005 17:10:00 6.7 1.4 9.9 3 6.6 1.5 11.1 2.6 5.2 1.4 9.5 2.3 42 24 18 300 6.2 0.4 6.7 5 12/29/2005 17:20:00 7.5 1.7 11.8 3.4 7.2 2.1 12.2 3 6.1 1.6 10.7 2.6 13 13 17 300 3.5 0.5 4.8 3.3 12/29/2005 17:30:00 8.8 1.2 11.8 4.9 8.1 1.5 12.6 4.6 6.8 1.4 10.7 3.4 17 9 20 300 3.2 0 3.3 3.3 12/29/2005 17:40:00 8 1.2 11.1 4.9 7.1 1.1 10.3 4.2 5.9 1.2 10.3 2.3 22 11 24 300 3.2 0 3.3 3.3 12/29/2005 17:50:00 7 1.5 11.1 3.4 6.7 1.6 10.3 3.4 5.6 1.4 10.3 2.6 15 13 15 300 3 0 3.3 2.8 12/29/2005 18:00:00 8.1 1.3 11.5 4.6 7.7 1.4 11.8 4.2 6.3 1.2 10.3 3.8 14 12 16 300 3 0.1 3.3 2.8 12/29/2005 18:10:00 8.1 1.3 11.1 3.4 7.4 1.4 11.5 3 6.1 1.4 10.3 2.3 20 12 8 300 3.3 0 3.5 3.3 12/29/2005 18:20:00 7.2 1.3 10.3 3.4 6.5 1.3 10.7 2.6 5.5 1.2 10.7 2.6 24 11 19 300 3.4 0 3.5 3.3 12/29/2005 18:30:00 7.4 1.2 9.9 4.2 6.9 1.2 9.9 3.4 5.8 1.2 9.5 3.4 23 13 13 300 3.3 0 3.5 3.3 12/29/2005 18:40:00 7.4 1.3 11.5 4.2 6.7 1.3 11.5 3.8 5.6 1.1 9.1 2.6 29 12 22 300 3.2 0 3.3 3.3 12/29/2005 18:50:00 7.7 1.5 11.5 3.8 7.2 1.5 11.1 3.4 5.9 1.4 9.9 2.6 18 12 14 300 3.1 0 3.3 2.8 12/29/2005 19:00:00 8.2 1.2 11.1 4.9 7.5 1.3 11.8 4.9 6.2 1.3 9.9 1.9 21 11 16 300 2.9 0 3 2.8 12/29/2005 19:10:00 8.2 1.2 10.7 4.6 7.6 1.3 10.7 3.4 6.2 1.3 9.5 2.3 19 11 22 300 3 0 3.3 2.8 12/29/2005 19:20:00 8.2 1.2 10.7 4.6 7.6 1.3 11.1 4.2 6.2 1.3 9.9 3 18 10 31 300 3.1 0 3.3 3 12/29/2005 19:30:00 7.3 1.2 10.7 4.6 6.9 1.3 11.5 3.4 5.8 1.2 8.8 2.3 18 11 12 300 3 0.1 3.3 2.8 12/29/2005 19:40:00 7.5 1.3 11.1 4.2 7.1 1.3 11.1 3.8 5.7 1.3 9.5 2.6 18 10 18 300 2.9 0 3 2.8 12/29/2005 19:50:00 7.2 1.1 9.5 3.4 6.7 1.2 9.9 3.8 5.7 1.2 9.1 2.3 22 12 22 300 2.7 0 2.8 2.6 12/29/2005 20:00:00 7.6 1.2 11.1 4.2 7 1.3 10.3 4.2 6 1.2 9.5 3 20 12 17 300 2.7 0 2.8 2.6 12/29/2005 20:10:00 7.1 1.4 10.3 4.2 6.5 1.4 10.7 3.4 5.5 1.3 10.3 2.6 19 11 21 300 2.9 0 2.8 2.8 12/29/2005 20:20:00 7.3 1.2 9.9 4.2 6.7 1.2 9.5 3.8 5.6 1.1 9.1 3 21 12 11 300 2.9 0 3 2.8 12/29/2005 20:30:00 7.3 1.2 10.3 4.2 6.7 1.2 10.3 3.8 5.6 1.1 9.9 3 22 12 10 300 2.9 0 3 2.8 12/29/2005 20:40:00 7.1 1.2 10.3 3.4 6.6 1.3 10.7 3 5.4 1.2 9.5 1.9 19 12 22 300 2.9 0 2.8 2.8 12/29/2005 20:50:00 7.3 1.5 10.7 3 6.9 1.5 11.1 3 5.8 1.3 10.3 1.9 19 11 31 300 2.9 0 2.8 2.8 12/29/2005 21:00:00 7.2 1.5 10.7 3.4 6.8 1.5 10.7 3 5.6 1.4 10.7 2.6 21 13 32 300 2.9 0 3 2.8 12/29/2005 21:10:00 8 1.3 11.5 3 7.3 1.4 11.5 2.6 6.2 1.3 10.3 3 20 11 17 300 3 0 3.3 2.8 12/29/2005 21:20:00 7.8 1.4 11.8 4.6 7.1 1.4 11.5 3.8 5.9 1.5 11.1 2.6 23 13 30 300 2.9 0 3.3 2.8 12/29/2005 21:30:00 8.5 1.3 11.1 4.9 7.9 1.5 11.8 4.9 6.5 1.2 11.1 3.4 19 11 5 300 3.1 0 3.3 3 12/29/2005 21:40:00 8 1.5 11.8 4.6 7.4 1.7 12.2 3.8 6.1 1.5 11.1 3 19 13 16 300 3.1 0 3.3 2.8 12/29/2005 21:50:00 7.7 1.2 10.7 4.2 7 1.3 10.3 3.4 5.8 1.2 9.9 3 20 10 32 300 2.9 0 3.3 2.8 12/29/2005 22:00:00 7.6 1.4 11.1 3.8 6.9 1.3 10.7 3.4 5.7 1.3 9.9 2.6 24 12 18 300 2.9 0 2.8 2.8 12/29/2005 22:10:00 7.7 1.4 11.8 4.2 7.1 1.3 11.5 3.4 5.8 1.3 9.5 2.6 24 13 40 300 2.8 0 2.8 2.8 12/29/2005 22:20:00 7.8 1.4 11.1 4.2 7.1 1.3 11.5 4.2 6.1 1.2 9.9 3 21 12 24 300 2.7 0 2.8 2.8 12/29/2005 22:30:00 8 1.3 11.5 3.8 7.2 1.2 10.3 3.8 6.1 1.3 9.9 2.3 24 11 25 300 2.8 0 2.8 2.8 12/29/2005 22:40:00 7.9 1.5 11.5 4.6 7.3 1.3 11.5 4.2 6.1 1.3 11.1 2.6 25 13 30 300 2.7 0 2.8 2.8 12/29/2005 22:50:00 6.8 1.3 10.7 3.4 6.2 1.2 10.3 3.4 5.1 1.2 8.4 2.3 27 14 31 300 2.7 0 2.8 2.6 12/29/2005 23:00:00 6 1 8.4 3.4 5.5 1 8.4 3 4.6 1 7.2 2.3 27 13 24 300 2.9 0 2.8 2.8 12/29/2005 23:10:00 5.1 0.9 7.2 3 4.8 0.9 6.8 2.6 3.8 0.9 6.1 1.9 32 12 20 300 2.7 0 2.8 2.6 12/29/2005 23:20:00 4.5 0.9 6.8 2.3 4.3 0.9 6.8 2.3 3.7 1 7.2 1.1 30 13 39 300 2.7 0 2.8 2.6 12/29/2005 23:30:00 5.4 1.2 8.4 2.6 5 1.2 8.4 2.3 4.3 1.1 8 1.9 27 13 16 300 2.7 0 2.8 2.6 12/29/2005 23:40:00 6.1 1.2 9.1 3 5.6 1.2 8.8 2.6 4.8 1 8.4 2.3 28 12 34 300 2.6 0 2.8 2.3 12/29/2005 23:50:00 6.7 1.1 10.3 3.8 6.1 1.1 9.5 3.4 5.1 1.1 8.8 2.6 26 11 31 300 2.3 0 2.6 2.3 12/30/2005 00:00:00 6.3 1.1 9.5 3 5.9 1.1 9.5 3 5 1 8 2.3 25 13 52 300 2.3 0 2.3 2.3 12/30/2005 00:10:00 7.2 1.4 10.3 3.8 6.4 1.3 9.9 3.4 5.4 1.2 9.5 2.3 24 12 25 300 2.3 0 2.6 2.3 12/30/2005 00:20:00 8.2 1.7 12.6 3.8 7.5 1.6 12.2 4.2 6.2 1.4 9.9 3 24 13 22 300 2.4 0 2.6 2.3 12/30/2005 00:30:00 8.9 1.5 12.2 4.6 8.1 1.5 13 4.6 6.9 1.3 10.3 3.8 25 11 30 300 2.3 0 2.6 2.3 12/30/2005 00:40:00 9.2 1.7 14.5 4.2 8.4 1.5 12.6 4.6 7.2 1.6 13 3.4 29 13 41 300 2.5 0 2.6 2.3 12/30/2005 00:50:00 9.2 1.5 13 5.3 8.4 1.5 11.8 4.6 6.8 1.5 10.3 3 29 13 23 300 2.5 0 2.8 2.3 12/30/2005 01:00:00 9.9 1.7 14.1 5.3 9.2 1.7 13.3 4.9 7.7 1.7 13 3.8 34 12 33 300 2.7 0 2.8 2.6 12/30/2005 01:10:00 9 1.7 13 2.6 8.4 1.6 13 3 7.1 1.7 12.6 2.6 33 14 38 300 2.6 0.1 2.8 2.6 12/30/2005 01:20:00 8.8 1.7 13 4.2 8.3 1.7 12.2 4.2 7 1.7 11.1 2.6 36 15 46 300 2.7 0 2.8 2.6 12/30/2005 01:30:00 8.8 1.6 13.7 4.9 8.1 1.5 12.6 4.6 6.9 1.5 12.6 3.8 31 13 26 300 2.7 0 2.8 2.6 12/30/2005 01:40:00 8.7 1.5 12.6 4.2 7.8 1.3 11.1 4.6 6.6 1.5 12.2 3.4 29 12 27 300 2.8 0 2.8 2.6 12/30/2005 01:50:00 8.3 1.5 12.2 4.2 7.6 1.4 11.1 3.8 6.5 1.5 11.5 2.6 30 12 18 300 2.6 0 2.8 2.6 12/30/2005 02:00:00 8.7 1.6 12.2 4.6 8.1 1.6 12.2 4.2 6.9 1.6 11.5 2.6 33 13 30 300 2.6 0 2.8 2.3 12/30/2005 02:10:00 8.7 1.7 13.7 3.8 8.1 1.6 12.2 3 6.9 1.7 11.5 3.4 33 12 31 300 2.6 0 2.8 2.3 12/30/2005 02:20:00 7.3 1.7 11.5 3.4 6.7 1.6 11.1 3 5.8 1.4 10.7 2.6 31 13 30 300 2.7 0 2.8 2.6 12/30/2005 02:30:00 7.9 1.3 12.2 3.8 7.5 1.3 11.8 4.2 6.2 1.3 11.1 3 35 13 18 300 2.7 0 2.8 2.6 12/30/2005 02:40:00 7.7 1.4 10.7 3.4 7.2 1.4 10.7 3.4 6 1.5 10.7 1.9 38 12 24 300 2.8 0 2.8 2.6 12/30/2005 02:50:00 7.4 1.5 12.2 3.8 7 1.5 12.2 3.4 5.8 1.3 11.5 3 37 15 41 300 2.9 0 2.8 2.8 12/30/2005 03:00:00 7.2 1.3 11.5 3.8 6.7 1.3 11.1 3.4 5.6 1.3 10.7 3 34 14 29 300 2.7 0 2.8 2.6 12/30/2005 03:10:00 7.4 1.7 11.5 2.6 6.9 1.7 11.5 1.9 5.6 1.5 9.1 1.9 36 12 35 300 2.6 0.1 2.8 2.6 12/30/2005 03:20:00 8 1.4 11.8 3.8 7.5 1.5 11.5 3.4 6.1 1.4 10.3 2.6 37 12 47 300 2.7 0 2.8 2.6 12/30/2005 03:30:00 6.4 1.4 10.3 3 6.1 1.4 9.9 3 4.9 1.3 8.4 1.5 37 12 44 300 2.6 0.1 2.8 2.3 12/30/2005 03:40:00 6.1 1.2 9.1 3.4 5.8 1.2 9.1 2.6 4.9 1.1 9.1 2.6 36 12 36 300 2.3 0 2.6 2.3 12/30/2005 03:50:00 5.4 1.1 8 2.6 5.2 1 7.6 2.6 4 1.3 7.6 1.1 41 13 28 300 2.3 0 2.6 2.1 12/30/2005 04:00:00 3.9 0.8 6.1 1.9 4 0.9 6.1 1.5 2.6 1 4.9 0.4 53 15 57 300 1.8 0 2.1 1.6 12/30/2005 04:10:00 3 0.6 4.6 1.5 3.1 0.6 4.9 1.9 2.2 0.8 4.6 0.7 52 9 59 300 1.7 0 1.8 1.4 12/30/2005 04:20:00 2.7 0.5 4.6 1.5 2.5 0.6 4.9 1.1 1.5 0.6 3.8 0.4 31 9 38 300 1 0.2 1.6 0.7 12/30/2005 04:30:00 2.6 0.5 3.8 1.5 2.6 0.4 3.8 1.5 2 0.5 3.4 1.1 44 11 31 300 0.7 0 0.9 0.7 12/30/2005 04:40:00 2.5 0.5 3.8 0.7 2.5 0.5 4.2 1.1 1.7 0.5 3.8 0.7 43 13 57 300 0.9 0 1.1 0.7 12/30/2005 04:50:00 2.3 0.8 4.2 0.7 2.3 0.8 4.2 0.4 1.5 0.6 3 0.4 43 14 60 300 0.8 0 0.9 0.7 12/30/2005 05:00:00 2.3 0.9 4.6 0.7 2.4 0.9 4.6 0.4 1.5 0.8 3.4 0.4 56 16 41 300 0.4 0.2 0.7 -0.1 12/30/2005 05:10:00 0.7 0.4 1.9 0.4 0.8 0.4 1.9 0.4 0.6 0.3 1.5 0.4 26 24 20 300 -0.5 0 -0.1 -0.7 12/30/2005 05:20:00 0.4 0.1 1.5 0.4 0.4 0.2 1.5 0.4 0.8 0.4 1.9 0.4 92 72 176 300 -0.9 0 -0.7 -1.2 12/30/2005 05:30:00 0.6 0.4 1.5 0.4 0.6 0.4 1.9 0.4 0.8 0.4 1.9 0.4 183 17 171 300 -1.2 0.1 -1 -1.4 12/30/2005 05:40:00 0.5 0.3 1.5 0.4 0.5 0.3 1.5 0.4 1 0.4 1.9 0.4 205 9 217 300 -1.8 0.2 -1.2 -2.1 12/30/2005 05:50:00 0.6 0.3 1.1 0.4 0.6 0.3 1.1 0.4 0.7 0.3 1.5 0.4 269 17 239 300 -2.3 0.1 -2.1 -2.6 12/30/2005 06:00:00 0.9 0.3 1.9 0.4 0.9 0.3 1.9 0.4 0.6 0.3 1.5 0.4 9 20 20 300 -2.6 0 -2.4 -2.6 12/30/2005 06:10:00 0.4 0.2 1.1 0.4 0.4 0.1 1.1 0.4 0.7 0.3 1.5 0.4 17 0 17 300 -2.3 0 -2.1 -2.6 12/30/2005 06:20:00 0.8 0.5 1.9 0.4 1 0.7 2.6 0.4 1.3 0.5 2.3 0.4 140 76 195 300 -2.2 0 -2.1 -2.4 12/30/2005 06:30:00 0.8 0.3 1.5 0.4 0.8 0.4 1.5 0.4 1.1 0.4 1.9 0.4 181 12 164 300 -2.4 0.1 -2.1 -2.6 12/30/2005 06:40:00 1.6 0.3 2.3 0.7 2 0.3 3 1.1 1.4 0.4 2.3 0.4 206 7 196 300 -2.6 0 -2.6 -2.8 12/30/2005 06:50:00 1.1 0.3 1.9 0.4 1 0.4 2.3 0.4 0.6 0.3 1.5 0.4 238 19 210 300 -2.7 0 -2.6 -2.8 12/30/2005 07:00:00 0.7 0.3 1.5 0.4 0.6 0.3 1.5 0.4 0.9 0.3 1.5 0.4 271 13 245 300 -2.6 0 -2.4 -2.6 12/30/2005 07:10:00 0.4 0.2 1.1 0.4 0.4 0.1 1.1 0.4 0.6 0.2 1.1 0.4 281 26 271 300 -2.4 0 -2.1 -2.6 12/30/2005 07:20:00 0.9 0.4 1.9 0.4 0.8 0.4 1.9 0.4 0.8 0.4 1.5 0.4 88 39 113 300 -2.4 0 -2.1 -2.6 12/30/2005 07:30:00 0.7 0.4 1.9 0.4 0.8 0.4 1.9 0.4 1 0.3 1.5 0.4 177 15 180 300 -2.8 0 -2.6 -2.8 12/30/2005 07:40:00 1 0.3 1.9 0.4 1.1 0.3 1.9 0.4 1.1 0.4 1.9 0.4 206 6 212 300 -2.9 0 -2.6 -3 12/30/2005 07:50:00 1.9 0.2 2.3 1.1 1.8 0.2 2.3 1.1 1.4 0.3 1.9 0.7 234 13 218 300 -3 0 -2.8 -3 12/30/2005 08:00:00 1.9 0.3 2.3 1.5 1.8 0.2 2.3 1.1 1.1 0.2 1.5 0.4 236 10 254 300 -2.8 0 -2.6 -2.8 12/30/2005 08:10:00 1.8 0.5 2.6 0.7 1.7 0.5 2.6 0.4 1.2 0.5 2.3 0.4 240 8 239 300 -2.9 0 -2.6 -3 12/30/2005 08:20:00 1.6 0.3 2.3 0.7 1.6 0.4 2.3 0.7 1.4 0.4 2.3 0.7 257 3 259 300 -2.8 0 -2.6 -3 12/30/2005 08:30:00 2.5 0.4 3.4 1.9 2.5 0.4 3.4 1.9 2.3 0.5 3.4 1.1 249 12 254 300 -2.7 0 -2.6 -2.8 12/30/2005 08:40:00 2.6 0.3 3.4 1.5 2.6 0.3 3.8 1.5 2.4 0.4 3 1.5 255 7 256 300 -2.8 0 -2.6 -2.8 12/30/2005 08:50:00 1.9 0.4 3 1.1 1.9 0.4 3 1.1 1.7 0.3 2.6 1.1 253 15 234 300 -2.7 0 -2.6 -2.8 12/30/2005 09:00:00 1.4 0.3 1.9 0.7 1.4 0.3 1.9 0.7 1.3 0.3 2.3 0.7 261 8 251 300 -2.8 0 -2.6 -2.8 12/30/2005 09:10:00 1.7 0.4 2.3 0.4 1.7 0.4 2.3 0.4 1.6 0.5 2.3 0.4 280 15 280 300 -2.8 0 -2.8 -2.8 12/30/2005 09:20:00 1.1 0.4 1.9 0.4 1.1 0.4 1.9 0.4 1.2 0.3 1.9 0.4 268 15 258 300 -2.8 0 -2.6 -2.8 12/30/2005 09:30:00 1.4 0.5 2.3 0.4 1.5 0.5 2.6 0.4 1.2 0.4 2.3 0.4 222 10 227 300 -2.9 0.1 -2.6 -3 12/30/2005 09:40:00 0.9 0.5 1.9 0.4 1 0.5 1.9 0.4 0.8 0.4 2.3 0.4 257 22 197 300 -3 0 -2.8 -3.3 12/30/2005 09:50:00 0.6 0.4 1.9 0.4 0.6 0.4 1.9 0.4 0.7 0.3 1.5 0.4 246 22 184 300 -3 0 -2.8 -3 12/30/2005 10:00:00 0.9 0.5 1.9 0.4 1 0.5 1.9 0.4 0.9 0.5 2.3 0.4 211 23 236 300 -2.9 0 -2.8 -3.3 12/30/2005 10:10:00 0.9 0.4 1.9 0.4 1.1 0.5 2.3 0.4 0.9 0.5 1.9 0.4 230 17 245 300 -3 0.1 -2.8 -3.3 12/30/2005 10:20:00 1.2 0.4 1.9 0.4 1.4 0.4 1.9 0.7 1.3 0.3 1.9 0.7 221 9 211 300 -3.2 0 -3 -3.3 12/30/2005 10:30:00 1.8 0.5 3 0.4 1.8 0.5 3 0.4 1.5 0.5 2.6 0.4 230 13 237 300 -3.1 0 -3 -3.3 12/30/2005 10:40:00 1.9 0.4 2.6 1.1 1.9 0.4 2.6 1.1 1.6 0.5 2.6 0.7 252 12 249 300 -3 0 -3 -3.3 12/30/2005 10:50:00 1.6 0.3 2.3 0.7 1.6 0.3 2.3 0.7 1.3 0.3 1.9 0.4 275 8 288 300 -3 0 -2.8 -3.3 12/30/2005 11:00:00 1.4 0.4 2.3 0.4 1.4 0.4 2.3 0.4 1.3 0.5 2.3 0.4 268 10 271 300 -2.9 0 -2.8 -3 12/30/2005 11:10:00 1 0.5 2.3 0.4 1.1 0.5 1.9 0.4 0.7 0.5 1.9 0.4 234 7 237 300 -2.8 0 -2.8 -2.8 12/30/2005 11:20:00 0.7 0.4 1.9 0.4 0.8 0.5 2.3 0.4 0.4 0.2 1.5 0.4 220 3 222 300 -2.7 0 -2.6 -2.8 12/30/2005 11:30:00 0.4 0.1 0.7 0.4 0.4 0.2 1.1 0.4 0.4 0.2 1.1 0.4 211 1 212 300 -2.6 0 -2.6 -2.8 12/30/2005 11:40:00 0.4 0 0.7 0.4 0.4 0.2 1.1 0.4 0.6 0.3 1.5 0.4 174 33 143 300 -2.6 0 -2.6 -2.6 12/30/2005 11:50:00 0.9 0.5 2.3 0.4 1 0.5 2.3 0.4 1.6 0.3 2.6 1.1 96 14 108 300 -2.4 0 -2.1 -2.6 12/30/2005 12:00:00 1.6 0.5 2.6 0.4 1.8 0.5 3 0.7 1.3 0.5 2.6 0.4 97 19 79 300 -1.7 0.3 -1.2 -2.1 12/30/2005 12:10:00 1 0.6 3.4 0.4 1.1 0.6 3 0.4 1 0.5 2.3 0.4 127 47 99 300 -1.5 0.1 -1.2 -1.9 12/30/2005 12:20:00 1.2 0.6 2.6 0.4 1.3 0.6 3 0.4 1.6 0.4 2.6 0.4 172 17 163 300 -2 0 -1.9 -2.1 12/30/2005 12:30:00 0.6 0.4 1.9 0.4 0.7 0.4 1.9 0.4 1.2 0.5 2.3 0.4 170 39 191 300 -1.6 0 -1.4 -1.9 12/30/2005 12:40:00 1.6 0.7 4.9 0.4 1.7 0.7 4.9 0.4 1.5 0.4 3 0.4 126 35 81 300 -1.3 0 -1.2 -1.4 12/30/2005 12:50:00 1.3 0.7 3 0.4 1.4 0.7 3.4 0.4 1.5 0.4 2.3 0.4 162 35 116 300 -1.2 0 -1 -1.2 12/30/2005 13:00:00 1.7 0.6 3 0.4 1.8 0.6 3.4 0.4 1.2 0.6 2.6 0.4 110 23 96 300 -1.2 0 -0.7 -1.2 12/30/2005 13:10:00 1.7 0.5 2.6 0.4 1.8 0.5 3 0.4 1.3 0.7 2.6 0.4 126 43 78 300 -0.6 0.1 -0.5 -1 12/30/2005 13:20:00 3.2 1.5 7.2 0.4 3.3 1.4 7.2 0.4 2.1 0.8 5.3 0.7 83 33 45 300 -0.7 0.2 -0.3 -1 12/30/2005 13:30:00 2.4 1 4.6 0.4 2.5 1 4.9 0.4 2.2 0.6 3.8 0.4 110 38 55 300 -0.5 0.3 -0.1 -1.2 12/30/2005 13:40:00 2.9 1 4.9 0.7 2.9 1.1 4.9 0.4 2.7 0.8 4.6 1.1 120 32 98 300 -0.6 0.5 0.2 -1.2 12/30/2005 13:50:00 2.2 0.8 4.6 0.7 2.2 0.9 4.6 0.4 1.6 0.6 3 0.4 101 35 77 300 -0.5 0 -0.1 -0.7 12/30/2005 14:00:00 3.2 0.6 4.6 1.9 3.2 0.6 4.6 1.5 2.5 0.4 3.8 1.1 103 15 113 300 -0.9 0 -0.5 -1.2 12/30/2005 14:10:00 3 1 6.8 1.1 3 0.9 6.5 1.1 1.5 0.8 4.2 0.4 57 20 43 300 -1 0 -1 -1.2 12/30/2005 14:20:00 3.6 1.4 8 0.4 3.4 1.3 8 0.4 3.1 0.8 6.1 1.1 69 51 48 300 0.2 0.8 1.8 -1 12/30/2005 14:30:00 3.9 1.5 8.8 0.4 3.9 1.4 8.4 1.5 2.9 1.2 8 0.4 51 27 40 300 -0.3 1 1.8 -1.2 12/30/2005 14:40:00 3.1 1.4 8.8 0.4 2.9 1.4 8.4 0.4 2.4 1 6.1 0.4 83 47 24 300 -0.6 1 1.8 -1.9 12/30/2005 14:50:00 2.4 0.8 4.9 0.4 2.4 0.8 4.9 0.4 2.2 0.7 3.8 0.4 107 51 39 300 -2.1 0 -1.7 -2.1 12/30/2005 15:00:00 2.3 1.2 7.2 0.4 2.2 1.1 7.6 0.4 1.6 0.8 5.7 0.4 96 69 67 300 -2.4 0 -2.1 -2.6 12/30/2005 15:10:00 6.2 2 10.7 1.5 5.8 1.7 10.3 1.5 4.2 1.7 10.3 0.7 38 22 28 300 -0.5 1.5 1.8 -2.6 12/30/2005 15:20:00 8 1.7 11.1 3.4 7.3 1.6 11.1 3 5.8 1.5 9.9 1.5 35 15 39 300 3.8 0.9 4.8 1.8 12/30/2005 15:30:00 8.1 1.3 11.5 4.6 7.2 1.1 11.5 4.2 6.1 1.3 9.5 2.6 29 11 32 300 4.8 0 4.8 4.5 12/30/2005 15:40:00 5.8 2 10.3 1.1 5.2 1.7 9.1 1.1 4.3 1.5 7.6 0.7 35 23 33 300 4.3 0.7 4.8 1.8 12/30/2005 15:50:00 2.6 0.9 4.9 0.4 2.7 0.9 4.6 0.4 2.8 0.6 4.2 0.7 151 36 138 300 -0.8 0.9 1.8 -1.9 12/30/2005 16:00:00 1.4 0.8 3.8 0.4 1.4 0.7 3.4 0.4 1.5 0.7 3.4 0.4 106 41 67 300 -1.9 0.1 -1.7 -2.1 12/30/2005 16:10:00 1.8 0.9 4.2 0.4 1.8 0.9 4.2 0.4 1.2 0.6 2.6 0.4 52 26 355 300 -2.1 0 -1.9 -2.1 12/30/2005 16:20:00 2.7 0.9 5.3 0.7 2.7 0.8 5.3 0.7 2.1 0.7 4.6 0.4 48 19 28 300 -1.7 0.3 -1 -2.1 12/30/2005 16:30:00 2 0.8 4.2 0.4 2.1 0.9 4.6 0.4 2 0.6 4.2 0.7 84 39 41 300 -2.2 0 -1.9 -2.6 12/30/2005 16:40:00 2.4 1 5.3 0.4 2.4 1 6.1 0.4 1.7 0.8 3.8 0.4 65 30 24 300 -2.4 0.2 -1.9 -2.6 12/30/2005 16:50:00 2.5 0.8 5.7 0.4 2.6 0.8 6.1 0.4 2.4 0.8 4.9 0.4 101 36 38 300 -2.4 0.1 -2.1 -2.6 12/30/2005 17:00:00 2.4 0.7 4.6 0.7 2.5 0.7 4.9 0.7 2.3 0.6 3.8 0.7 88 26 93 300 -2.7 0 -2.6 -2.8 12/30/2005 17:10:00 2.1 0.9 6.5 0.4 2.2 1 6.1 0.4 2.4 0.6 3.8 0.4 113 35 38 300 -2.9 0 -2.6 -3 12/30/2005 17:20:00 1 0.7 3.4 0.4 1.2 0.7 3 0.4 1.2 0.7 3 0.4 96 41 37 300 -2.9 0 -2.8 -3 12/30/2005 17:30:00 2.7 1.7 6.5 0.4 2.7 1.6 6.5 0.4 1.8 1.5 6.1 0.4 42 15 38 300 -2.8 0.5 -1.4 -3 12/30/2005 17:40:00 4.9 1 8 2.6 4.8 1.1 8.4 2.6 3.7 1.1 7.2 1.5 43 12 32 300 0.3 0.7 1.4 -1.4 12/30/2005 17:50:00 2.4 1 5.3 0.4 2.5 0.9 5.3 0.4 2 0.7 4.6 0.4 68 27 42 300 -1 1.1 1.1 -2.1 12/30/2005 18:00:00 2.1 0.7 4.2 0.4 2.2 0.6 4.2 0.4 2.1 0.6 3.4 0.4 92 30 75 300 -2.5 0.2 -2.1 -2.8 12/30/2005 18:10:00 2.3 0.8 4.2 0.7 2.4 0.8 4.2 0.4 1.8 0.7 4.2 0.4 69 18 77 300 -2.7 0 -2.6 -2.8 12/30/2005 18:20:00 4.3 1.5 8 1.1 4.1 1.5 8 1.1 3.3 1.3 7.2 1.1 41 15 49 300 -1.2 1.2 0.9 -2.8 12/30/2005 18:30:00 5.3 1.1 8.4 2.3 5 1.1 8.4 2.6 4 1.1 7.2 1.5 32 15 16 300 2 0.4 2.6 1.1 12/30/2005 18:40:00 4.9 1.4 8 0.4 4.7 1.3 8 1.5 3.8 1.3 8.4 0.7 40 21 26 300 2.8 0 2.8 2.6 12/30/2005 18:50:00 5.1 1.5 9.5 1.1 4.9 1.5 9.5 0.7 4 1.4 9.1 1.5 42 18 39 300 2.9 0 3.3 2.8 12/30/2005 19:00:00 5.3 1.1 8.4 2.3 5.2 1.2 8.8 2.6 4.4 1.2 8.8 1.1 40 15 36 300 3.1 0 3.3 3 12/30/2005 19:10:00 5.2 1.2 8 1.9 5.1 1.2 7.6 1.9 4.1 1.1 6.8 1.1 40 18 28 300 3.2 0 3.3 3 12/30/2005 19:20:00 4.9 1.2 8.4 1.9 4.8 1.1 7.6 1.1 3.8 1.3 6.5 1.1 42 19 40 300 3.2 0 3.3 3.3 12/30/2005 19:30:00 3.9 1.3 7.2 0.7 3.8 1.3 7.2 1.1 3 1.3 6.5 0.4 44 20 49 300 2.9 0.1 3.3 2.6 12/30/2005 19:40:00 4.8 1.1 7.6 1.9 4.7 1.1 7.6 1.5 4 1 7.6 1.1 41 14 40 300 3 0.1 3.3 2.8 12/30/2005 19:50:00 4.4 1.2 8.8 1.5 4.3 1.2 9.1 1.5 3.6 1.2 7.2 1.1 45 16 36 300 3.2 0 3.3 3.3 12/30/2005 20:00:00 4.9 1.2 9.1 2.3 4.7 1.1 9.5 1.9 3.8 1.1 8.8 1.9 37 16 44 300 3.3 0 3.5 3.3 12/30/2005 20:10:00 6.1 1.5 9.9 2.3 5.8 1.5 9.9 2.3 4.8 1.5 9.5 1.5 37 16 37 300 3.5 0 3.5 3.5 12/30/2005 20:20:00 7.7 1.7 11.5 3.8 7.3 1.5 10.7 3.8 6 1.4 11.1 3 36 16 22 300 3.4 0 3.5 3.3 12/30/2005 20:30:00 8.2 1.5 12.2 4.6 7.7 1.5 11.5 4.2 6.3 1.4 10.3 3 34 14 30 300 3.3 0 3.5 3.3 12/30/2005 20:40:00 6.8 1.5 11.1 3 6.4 1.5 11.5 2.6 5.6 1.3 9.5 2.6 36 15 31 300 3.3 0 3.5 3.3 12/30/2005 20:50:00 6.7 1.5 11.5 3 6.4 1.5 11.5 2.3 5.4 1.5 11.5 1.5 36 14 46 300 3.5 0 3.5 3.5 12/30/2005 21:00:00 6 1.5 9.1 2.3 5.8 1.5 9.1 2.3 4.8 1.2 8 2.3 39 16 46 300 3.5 0 3.8 3.5 12/30/2005 21:10:00 6.2 1.3 9.5 2.6 5.8 1.3 9.1 2.3 4.7 1.3 8.8 1.5 34 17 25 300 3.5 0 3.5 3.5 12/30/2005 21:20:00 5.9 1.2 9.1 1.9 5.7 1.2 8.8 2.6 4.7 1.3 8.4 1.5 39 18 36 300 3.5 0 3.5 3.5 12/30/2005 21:30:00 6.7 1.6 10.7 2.3 6.3 1.4 10.3 2.3 5.4 1.2 10.3 2.6 34 17 28 300 3.6 0 3.8 3.5 12/30/2005 21:40:00 7.6 1.9 13 2.6 7.1 1.8 12.2 2.6 6 1.7 10.3 2.3 35 15 35 300 3.5 0 3.8 3.5 12/30/2005 21:50:00 8.3 1.7 12.6 4.2 7.7 1.6 11.5 4.2 6.3 1.7 11.8 2.6 31 14 25 300 3.3 0 3.5 3.3 12/30/2005 22:00:00 7.7 1.8 12.6 3.4 7.1 1.7 12.2 3.4 5.9 1.5 9.9 2.6 33 17 30 300 3.2 0 3.3 3.3 12/30/2005 22:10:00 5.9 1.7 10.7 1.9 5.6 1.6 10.3 1.9 4.7 1.5 9.9 0.7 36 21 35 300 3.2 0 3.3 3 12/30/2005 22:20:00 4.9 1.5 9.1 0.7 5 1.5 9.5 1.1 4.4 1.3 8 1.1 50 23 54 300 3 0 3.3 2.8 12/30/2005 22:30:00 6.5 1.2 9.9 3 6.2 1.1 9.1 3.4 5.2 1.2 8.8 2.6 35 14 21 300 3 0 3.3 2.8 12/30/2005 22:40:00 5.9 1.5 9.5 2.6 5.5 1.5 9.5 1.9 4.7 1.3 8.4 1.5 35 18 18 300 3 0 3.3 2.8 12/30/2005 22:50:00 6.1 1.2 9.5 3.4 5.7 1.2 9.5 3 5 1.2 8.4 2.3 31 15 20 300 2.9 0 3 2.8 12/30/2005 23:00:00 6.5 1.5 10.3 2.6 6.1 1.5 10.3 2.6 5.3 1.4 9.9 1.9 36 17 33 300 2.9 0 3.3 2.8 12/30/2005 23:10:00 6.5 1.9 11.5 2.3 6.1 1.7 10.7 2.6 5.3 1.5 9.9 1.9 36 17 24 300 2.8 0 2.8 2.8 12/30/2005 23:20:00 7.5 1.6 11.5 3.8 6.8 1.3 10.3 3.4 5.6 1.4 9.5 1.9 34 13 26 300 2.9 0 2.8 2.8 12/30/2005 23:30:00 6.7 1.5 9.9 2.6 6.3 1.4 9.9 2.6 5.1 1.5 9.1 1.9 36 16 7 300 2.9 0 2.8 2.8 12/30/2005 23:40:00 4.4 1.4 8.8 1.1 4.4 1.5 8.8 1.1 3.4 1.5 7.6 0.7 47 20 28 300 2.8 0 2.8 2.6 12/30/2005 23:50:00 3.1 1.2 6.8 0.4 3.2 1.1 6.8 1.1 2.6 0.9 6.1 0.7 84 47 32 300 0.6 1.3 2.6 -1.2 12/31/2005 00:00:00 2.9 0.6 4.9 1.5 3 0.6 4.6 1.5 2.8 0.5 4.2 0.7 124 38 126 300 -1.6 0 -1.2 -1.7 12/31/2005 00:10:00 1.9 0.8 3.8 0.4 2.1 0.8 4.2 0.4 1.8 0.5 3.4 0.7 81 30 83 300 -1.5 0 -1.4 -1.7 12/31/2005 00:20:00 1.1 0.5 2.3 0.4 1.3 0.6 2.3 0.4 1.5 0.5 2.6 0.4 139 58 203 300 -1.7 0 -1.4 -1.9 12/31/2005 00:30:00 0.8 0.5 1.9 0.4 1.1 0.6 2.3 0.4 1.6 0.5 2.6 0.4 175 28 183 300 -1.8 0 -1.7 -1.9 12/31/2005 00:40:00 0.7 0.4 2.3 0.4 0.8 0.6 2.6 0.4 1 0.5 2.3 0.4 158 58 55 300 -2 0 -1.9 -2.1 12/31/2005 00:50:00 2.2 1 5.3 0.4 2.4 1 5.7 0.4 1.6 0.9 3.8 0.4 58 22 54 300 -2 0 -1.4 -2.1 12/31/2005 01:00:00 3.2 0.9 5.7 1.1 3.1 1 6.1 1.1 2.2 0.9 6.1 0.4 43 16 65 300 -1.4 0.3 -0.7 -1.9 12/31/2005 01:10:00 4.2 1.3 8 1.5 4.1 1.2 8 1.5 3.5 1 6.8 1.1 41 17 9 300 0.8 0.7 1.8 -0.7 12/31/2005 01:20:00 3.1 1.3 7.6 0.4 3.1 1.3 7.2 0.4 2.9 1.2 5.7 0.4 69 36 43 300 0.4 0.9 1.8 -0.7 12/31/2005 01:30:00 2.7 1 5.7 0.7 2.8 1 6.1 1.1 2.2 0.8 4.9 0.4 92 39 55 300 -1.3 0.3 -0.7 -2.1 12/31/2005 01:40:00 1.7 0.8 3.8 0.4 1.8 0.8 4.2 0.4 2.4 0.7 4.6 0.7 156 29 183 300 -2.4 0.2 -1.9 -2.6 12/31/2005 01:50:00 1.8 0.5 3 0.7 2.3 0.5 3.4 1.1 2 0.4 3 0.4 197 10 196 300 -2.8 0.1 -2.6 -3 12/31/2005 02:00:00 1.6 0.8 3 0.4 1.9 0.9 3 0.4 1.8 0.8 3 0.4 193 8 189 300 -3 0 -2.8 -3 12/31/2005 02:10:00 1.1 0.6 2.6 0.4 1.4 0.7 3 0.4 1.2 0.6 2.6 0.4 193 13 183 300 -3.1 0 -3 -3.3 12/31/2005 02:20:00 1 0.5 2.6 0.4 1.4 0.5 3 0.4 1.5 0.7 3 0.4 209 21 195 300 -3.2 0 -3.3 -3.3 12/31/2005 02:30:00 1.4 0.8 3 0.4 1.7 0.9 3.8 0.4 1.6 1 3.4 0.4 239 47 196 300 -3.1 0 -3 -3.3 12/31/2005 02:40:00 1.9 0.8 3.4 0.4 2.5 1 3.8 0.4 2.5 0.7 3.4 0.7 205 9 212 300 -3.2 0 -3 -3.3 12/31/2005 02:50:00 2.1 0.6 3.8 0.7 2.3 0.6 4.2 1.1 2 0.7 3.4 0.4 217 15 227 300 -3.4 0 -3.3 -3.5 12/31/2005 03:00:00 1.9 0.4 2.6 0.4 1.9 0.4 2.6 0.7 1.9 0.5 3 0.7 234 13 227 300 -3.3 0 -3.3 -3.5 12/31/2005 03:10:00 1.2 0.6 3 0.4 1.4 0.7 3 0.4 1.7 0.7 3 0.4 225 22 191 300 -3.2 0 -3.3 -3.5 12/31/2005 03:20:00 1.2 0.6 2.6 0.4 1.5 0.6 3 0.4 2 0.6 3 0.4 196 19 190 300 -3.5 0 -3.3 -3.5 12/31/2005 03:30:00 0.9 0.6 2.3 0.4 0.9 0.6 2.6 0.4 1 0.6 2.3 0.4 137 76 219 300 -3.7 0 -3.5 -3.7 12/31/2005 03:40:00 2.2 0.6 3.4 0.4 2.5 0.5 3.4 0.7 2.6 0.4 3.4 1.5 183 22 193 300 -3.8 0 -3.5 -3.7 12/31/2005 03:50:00 1.9 0.6 3.4 0.4 2.3 0.6 3.8 0.7 2.1 0.8 3.4 0.4 217 49 221 300 -3.8 0 -3.7 -3.9 12/31/2005 04:00:00 1.5 0.7 3.4 0.4 1.7 0.7 3.4 0.4 1.9 0.9 3.4 0.4 212 13 193 300 -3.8 0 -3.5 -3.9 12/31/2005 04:10:00 2.1 0.3 3 1.5 2.3 0.3 3 1.5 2.1 0.4 2.6 0.7 217 6 211 300 -3.8 0 -3.7 -3.9 12/31/2005 04:20:00 1.5 0.3 2.3 0.7 1.8 0.3 2.6 1.1 1.6 0.4 2.3 0.7 212 10 222 300 -4 0 -3.9 -4.2 12/31/2005 04:30:00 1 0.5 2.3 0.4 1.3 0.5 2.3 0.4 1 0.5 1.9 0.4 220 7 224 300 -4.1 0 -3.9 -4.2 12/31/2005 04:40:00 1.2 0.5 2.6 0.4 1.6 0.5 2.6 0.4 1.4 0.6 2.6 0.4 210 7 194 300 -4.4 0 -3.9 -4.6 12/31/2005 04:50:00 0.5 0.3 1.9 0.4 0.6 0.3 1.5 0.4 1 0.5 2.3 0.4 188 47 230 300 -4.5 0 -4.4 -4.6 12/31/2005 05:00:00 0.9 0.6 2.6 0.4 1.1 0.7 2.6 0.4 1 0.7 2.3 0.4 198 15 187 300 -4.5 0 -4.4 -4.6 12/31/2005 05:10:00 1 0.5 3 0.4 1.1 0.5 3 0.4 0.9 0.5 2.3 0.4 228 14 220 300 -4.7 0 -4.6 -4.8 12/31/2005 05:20:00 1.4 0.3 2.3 0.4 1.5 0.3 2.3 0.7 1 0.5 2.3 0.4 251 9 244 300 -4.5 0 -4.4 -4.6 12/31/2005 05:30:00 1.8 0.4 2.6 1.1 1.8 0.3 2.6 1.1 1.6 0.3 2.3 0.7 234 9 229 300 -4.6 0 -4.4 -4.6 12/31/2005 05:40:00 2.3 0.5 3.4 0.7 2.3 0.4 3.4 1.1 1.8 0.5 3 0.4 228 11 229 300 -4.8 0 -4.6 -4.8 12/31/2005 05:50:00 1.8 0.6 2.6 0.4 2 0.6 3 0.4 1.4 0.7 2.6 0.4 244 18 220 300 -4.8 0 -4.6 -4.8 12/31/2005 06:00:00 1.4 0.6 2.6 0.4 1.5 0.6 2.3 0.4 1.1 0.5 2.3 0.4 242 15 208 300 -4.8 0 -4.6 -5 12/31/2005 06:10:00 0.6 0.4 1.9 0.4 0.6 0.4 1.9 0.4 0.8 0.5 1.9 0.4 313 69 66 300 -4.7 0.1 -4.4 -4.8 12/31/2005 06:20:00 1.2 0.6 3.4 0.4 1.3 0.6 3.4 0.4 1.1 0.4 2.6 0.4 51 36 54 300 -4.7 0 -4.6 -4.8 12/31/2005 06:30:00 2.4 0.5 3.8 1.1 2.6 0.6 4.2 1.5 2.3 0.8 3.8 0.4 210 26 181 300 -4.9 0 -4.6 -5 12/31/2005 06:40:00 1.4 0.7 2.6 0.4 1.5 0.7 3 0.4 1.3 0.5 2.3 0.4 222 21 224 300 -4.9 0 -4.8 -5 12/31/2005 06:50:00 1.1 0.4 1.9 0.4 1.4 0.4 2.3 0.4 1 0.4 1.5 0.4 206 8 210 300 -5 0 -4.8 -5 12/31/2005 07:00:00 1.3 0.6 2.6 0.4 1.4 0.6 2.3 0.4 1.3 0.5 2.3 0.4 219 9 222 300 -5.2 0 -5 -5.3 12/31/2005 07:10:00 1 0.4 1.9 0.4 1.4 0.5 2.3 0.4 1.4 0.5 2.3 0.4 200 24 213 300 -5 0 -5 -5.3 12/31/2005 07:20:00 1.6 0.5 2.6 0.4 1.8 0.5 2.6 0.4 1.9 0.3 2.6 1.1 187 13 183 300 -4.9 0 -4.8 -5 12/31/2005 07:30:00 0.9 0.6 2.6 0.4 1 0.6 2.6 0.4 1.4 0.5 2.6 0.4 181 17 190 300 -5.2 0.1 -4.8 -5.3 12/31/2005 07:40:00 0.6 0.4 1.5 0.4 0.9 0.6 1.9 0.4 1.4 0.4 2.3 0.7 194 30 209 300 -5.2 0 -5 -5.3 12/31/2005 07:50:00 0.4 0.1 1.1 0.4 0.4 0.2 1.1 0.4 1 0.4 1.9 0.4 115 43 147 300 -5.3 0 -5 -5.5 12/31/2005 08:00:00 1.4 0.6 3 0.4 1.5 0.6 2.6 0.4 1.4 1 3.4 0.4 123 56 174 300 -5.2 0.1 -4.8 -5.9 12/31/2005 08:10:00 1.6 1.1 4.9 0.4 1.7 1 4.6 0.4 1.3 0.8 4.6 0.4 88 53 25 300 -4.9 0.1 -4.4 -5 12/31/2005 08:20:00 2.1 1 5.3 0.4 2.1 0.9 4.6 0.4 2 0.7 3.8 0.4 88 39 53 300 -4.2 0.3 -3.7 -4.6 12/31/2005 08:30:00 1.3 0.7 3 0.4 1.4 0.8 3.4 0.4 1.7 0.9 3 0.4 124 51 105 300 -4.8 0 -4.6 -5 12/31/2005 08:40:00 1.9 0.4 3 0.7 2.3 0.5 3 0.7 2.2 0.4 3 1.1 205 9 218 300 -5 0 -4.8 -5.3 12/31/2005 08:50:00 1.8 0.7 3 0.4 2 0.8 3.4 0.4 1.4 0.7 3 0.4 215 8 219 300 -5.4 0 -5 -5.5 12/31/2005 09:00:00 0.7 0.4 1.9 0.4 0.8 0.5 1.9 0.4 0.8 0.5 1.9 0.4 218 13 213 300 -5.2 0 -5 -5.5 12/31/2005 09:10:00 0.6 0.3 1.5 0.4 0.6 0.3 1.5 0.4 0.7 0.5 1.9 0.4 298 79 223 300 -5 0 -4.8 -5 12/31/2005 09:20:00 1.8 0.8 3.8 0.4 1.9 0.8 4.2 0.4 1.2 0.6 2.3 0.4 69 17 57 300 -4.9 0 -4.8 -5 12/31/2005 09:30:00 2.1 0.7 4.9 0.7 2.2 0.7 4.6 0.7 1.5 0.5 2.6 0.4 77 23 83 300 -4.8 0.1 -4.2 -5 12/31/2005 09:40:00 2.4 0.7 4.6 0.4 2.4 0.7 4.6 0.4 1.8 0.7 3.8 0.4 68 27 96 300 -4.1 0.2 -3.7 -4.4 12/31/2005 09:50:00 1.8 0.6 3.4 0.4 1.9 0.5 3.4 0.4 2 0.4 3 0.7 116 28 86 300 -4.2 0.1 -3.9 -4.4 12/31/2005 10:00:00 1.7 0.6 3 0.4 1.8 0.5 3 0.4 1.8 0.5 3 0.7 124 35 138 300 -4.4 0 -3.9 -4.6 12/31/2005 10:10:00 1.3 0.7 2.6 0.4 1.4 0.7 2.6 0.4 1.4 0.6 2.6 0.4 124 49 69 300 -4.7 0.1 -4.4 -4.8 12/31/2005 10:20:00 0.8 0.6 3 0.4 0.9 0.6 2.6 0.4 1.5 0.8 3 0.4 147 47 185 300 -4.9 0 -4.8 -5 12/31/2005 10:30:00 1.5 0.7 3.4 0.4 1.7 0.9 3.4 0.4 2.1 0.7 3.8 0.7 164 53 202 300 -4.9 0 -4.8 -5 12/31/2005 10:40:00 0.7 0.5 2.3 0.4 0.8 0.7 3 0.4 1.1 0.6 3 0.4 259 58 213 300 -5 0 -4.8 -5 12/31/2005 10:50:00 1.2 0.8 3.4 0.4 1.2 0.8 3.8 0.4 0.8 0.5 2.3 0.4 75 58 15 300 -5 0 -5 -5.3 12/31/2005 11:00:00 3.3 1 5.7 1.1 3.3 1 6.1 1.1 2.4 0.9 4.9 0.4 46 16 41 300 -4.1 0.8 -2.4 -5 12/31/2005 11:10:00 3.9 1.5 8 0.7 3.7 1.4 7.6 0.7 2.7 1.1 5.7 0.7 53 28 19 300 -1.4 0.4 -1 -2.4 12/31/2005 11:20:00 2.2 1.1 4.6 0.4 2.2 1 4.6 0.4 1.6 0.8 3.4 0.4 69 43 8 300 -2.8 0.4 -1.9 -3.5 12/31/2005 11:30:00 3.6 1.7 7.6 0.7 3.5 1.7 8 0.7 2.8 1.3 6.5 0.4 46 17 68 300 -2.7 0.7 -1 -3.5 12/31/2005 11:40:00 5.7 1.1 8.4 1.9 5.3 1.1 8 1.5 4.4 1.2 8.4 1.5 37 14 28 300 0.5 0.5 1.4 -1 12/31/2005 11:50:00 6.3 1.2 9.1 3 5.8 1.2 8.8 2.6 4.8 1.2 8.4 2.6 31 13 24 300 1.3 0.1 1.6 0.9 12/31/2005 12:00:00 6.3 1.1 9.5 3 5.8 1.1 8.8 2.3 4.5 1.3 8.4 1.5 32 14 32 300 1.4 0 1.6 1.4 12/31/2005 12:10:00 5.8 1.1 8.4 3 5.6 1.1 8.4 2.6 4.6 1.1 7.2 1.5 40 12 34 300 1.4 0 1.6 1.4 12/31/2005 12:20:00 6.1 1.2 9.5 3.4 5.6 1 9.1 3 4.9 1.1 8.4 2.3 32 12 359 300 1.4 0 1.6 1.4 12/31/2005 12:30:00 6.2 1.1 8.8 3.8 5.7 1 8.4 3.4 4.8 1.1 8 2.3 30 14 21 300 1.4 0 1.6 1.4 12/31/2005 12:40:00 7.2 1.3 10.3 4.2 6.4 1.2 9.9 3.8 5.4 1.1 8.8 2.6 28 11 353 300 1.5 0 1.6 1.6 12/31/2005 12:50:00 6.7 1.3 10.7 3.8 6.1 1.2 10.7 2.6 5 1.1 8.4 2.6 29 13 11 300 1.5 0 1.6 1.6 12/31/2005 13:00:00 6.8 1.2 9.5 4.2 6.3 1.2 9.1 3.8 5 1.2 8.4 2.6 28 13 24 300 1.5 0 1.6 1.4 12/31/2005 13:10:00 6.4 1.3 9.5 2.3 5.9 1.3 9.1 2.3 4.9 1.1 8.4 2.6 25 12 30 300 1.4 0 1.6 1.4 12/31/2005 13:20:00 6.1 1.1 8.4 3 5.5 1.1 8 2.3 4.6 1 7.2 1.9 27 12 29 300 1.5 0 1.6 1.4 12/31/2005 13:30:00 6.9 1.3 10.3 3.8 6.2 1.2 9.5 3 5.2 1.1 8.8 2.6 25 13 38 300 1.8 0 1.8 1.6 12/31/2005 13:40:00 6.8 1.2 10.3 3.8 6.3 1.2 9.1 3 5 1.1 8 2.3 28 15 33 300 1.7 0 1.8 1.6 12/31/2005 13:50:00 6.3 1.2 9.5 3.8 5.9 1.2 9.9 3.4 4.9 1.1 7.2 1.9 26 15 32 300 1.7 0 1.8 1.6 12/31/2005 14:00:00 5.5 1.4 9.1 1.9 5 1.4 8.4 1.5 4.1 1.2 7.2 1.5 24 15 52 300 1.7 0 1.8 1.6 12/31/2005 14:10:00 6.3 1.8 10.7 2.3 5.8 1.7 11.1 2.3 4.9 1.4 9.5 1.9 27 17 26 300 1.7 0 1.8 1.6 12/31/2005 14:20:00 7.1 1.4 10.7 3 6.5 1.3 10.3 3.4 5.6 1.3 10.3 2.3 24 14 32 300 1.7 0 1.8 1.6 12/31/2005 14:30:00 7.7 1.5 11.5 4.2 6.9 1.4 11.1 3.8 6 1.3 9.5 3 27 12 28 300 1.6 0 1.8 1.6 12/31/2005 14:40:00 8.3 1.4 11.1 3.8 7.3 1.3 9.9 3.8 6.1 1.5 10.7 1.9 29 12 28 300 1.7 0 1.8 1.6 12/31/2005 14:50:00 7.2 1.4 10.3 4.2 6.5 1.2 9.9 3.8 5.3 1.3 8.8 1.9 28 15 25 300 1.7 0 1.8 1.6 12/31/2005 15:00:00 5.2 1.2 8.4 1.9 5.1 1.2 8 1.9 4.1 1 6.8 1.9 39 17 39 300 1.7 0 1.6 1.6 12/31/2005 15:10:00 5.7 1 8 2.3 5.5 1 8 2.3 4.5 1 7.2 2.3 37 12 41 300 1.7 0 1.8 1.6 12/31/2005 15:20:00 7 1.3 9.9 3.4 6.3 1.1 9.1 3 5.2 1.1 8.8 1.9 30 10 36 300 1.7 0 1.8 1.6 12/31/2005 15:30:00 6.8 1.3 10.7 3 6.2 1.2 9.9 3 5.1 1.1 8 1.9 23 12 16 300 1.7 0 1.8 1.6 12/31/2005 15:40:00 7.7 1.2 10.7 4.6 7 1.2 10.3 3.8 5.7 1.2 9.1 2.6 23 12 20 300 1.5 0 1.6 1.4 12/31/2005 15:50:00 7.3 1.5 10.7 3.8 6.7 1.3 9.9 3.4 5.7 1.2 9.1 3 22 15 27 300 1.3 0 1.6 1.4 12/31/2005 16:00:00 6.6 1.4 10.7 3 6.1 1.3 10.7 3 5 1.2 8.4 2.6 24 14 16 300 1.2 0 1.4 1.4 12/31/2005 16:10:00 6.5 1.3 9.9 3.4 6 1.1 8.8 3 5.3 1.1 8.8 2.6 33 12 25 300 1.4 0 1.6 1.4 12/31/2005 16:20:00 6.7 1.4 11.5 3.8 6.1 1.2 9.1 3.4 5.1 1.2 8.4 2.6 30 13 22 300 1.4 0 1.6 1.4 12/31/2005 16:30:00 7.1 1.1 9.9 3.4 6.4 1.2 9.5 2.6 5.4 1.1 8 2.6 29 11 19 300 1.6 0 1.8 1.6 12/31/2005 16:40:00 7.8 1.5 11.5 3 7 1.4 10.7 2.6 5.5 1.5 9.5 1.5 25 13 26 300 1.5 0 1.6 1.4 12/31/2005 16:50:00 7.5 1.2 9.9 4.2 6.7 1.2 9.5 3.4 5.6 1.2 8.8 3 30 12 27 300 1.6 0 1.6 1.6 12/31/2005 17:00:00 7.2 1.3 11.1 4.2 6.4 1.2 9.5 3.8 5.3 1.2 9.5 1.9 30 14 28 300 1.6 0 1.6 1.6 12/31/2005 17:10:00 6.3 1.3 10.3 2.3 5.8 1.1 9.5 2.6 4.9 1.2 8 2.6 35 17 62 300 1.4 0 1.6 1.4 12/31/2005 17:20:00 5.6 1.4 9.5 2.6 5.3 1.3 8.8 2.3 4.6 1.2 8.8 2.3 32 17 16 300 1.4 0 1.4 1.4 12/31/2005 17:30:00 6.1 1.2 9.1 3 5.7 1.2 8.8 2.3 4.6 1.1 8 1.5 28 16 24 300 1.3 0 1.4 1.4 12/31/2005 17:40:00 6.6 1.3 9.9 3.4 6.1 1.4 9.9 3 4.9 1.2 8 2.6 24 15 10 300 1.3 0 1.4 1.4 12/31/2005 17:50:00 5.9 1.3 9.5 3 5.5 1.3 9.5 2.6 4.5 1.2 8.8 1.5 24 17 10 300 1.2 0 1.4 1.4 12/31/2005 18:00:00 5.7 1.4 9.1 2.3 5.3 1.3 8.8 1.5 4.4 1.3 8 0.4 32 17 31 300 1.2 0 1.4 1.1 12/31/2005 18:10:00 5.3 1.3 8.4 1.9 4.9 1.2 7.6 2.3 4.1 1.1 7.6 1.9 34 16 30 300 1.2 0 1.4 1.4 12/31/2005 18:20:00 3.8 1.5 8.4 0.4 3.7 1.5 8.4 0.4 3.2 1.2 7.6 0.7 44 24 17 300 1.3 0 1.4 1.4 12/31/2005 18:30:00 3.8 1 6.8 1.5 3.8 1 6.5 1.5 3 1 5.7 1.1 44 20 42 300 1.4 0 1.6 1.4 12/31/2005 18:40:00 5.5 1.4 9.1 2.6 5.1 1.3 8.4 2.3 4.3 1.3 7.6 1.1 31 17 28 300 1.5 0 1.6 1.4 12/31/2005 18:50:00 5.3 1.2 8.4 1.5 5 1.2 8 1.9 4.3 1.2 8 1.9 39 17 32 300 1.4 0 1.6 1.4 12/31/2005 19:00:00 4.9 1.3 8.4 1.5 4.7 1.3 8.8 1.5 4.1 1.3 7.6 0.7 37 19 37 300 1.2 0 1.4 1.1 12/31/2005 19:10:00 4.5 1.1 7.6 1.5 4.3 1 8 1.5 3.7 1.2 7.6 1.5 40 20 57 300 1.2 0 1.4 1.1 12/31/2005 19:20:00 5.3 1.2 8 2.3 4.8 1.2 8.8 2.3 3.5 1.2 7.6 1.1 27 19 17 300 1.4 0 1.6 1.4 12/31/2005 19:30:00 5.4 1.2 8.4 2.3 5 1.2 8.4 1.9 4.1 1.2 7.2 1.1 33 16 19 300 1.4 0 1.6 1.4 12/31/2005 19:40:00 5.5 1.3 9.1 2.6 5.5 1.2 8.4 2.6 4.6 1.3 7.6 1.5 43 15 30 300 1.4 0 1.6 1.4 12/31/2005 19:50:00 7.5 1.3 10.7 3.4 6.8 1.1 9.5 3.4 5.6 1.2 9.1 1.9 34 11 28 300 1.6 0 1.8 1.6 12/31/2005 20:00:00 5.5 1.8 9.5 1.1 5 1.6 9.1 1.1 3.9 1.5 8 0.7 35 22 24 300 1.7 0 1.8 1.6 12/31/2005 20:10:00 5.1 1.2 8.4 1.5 4.7 1.2 7.6 1.9 4.1 1.1 7.2 1.5 33 16 31 300 1.7 0 1.8 1.6 12/31/2005 20:20:00 6.1 1.1 8.8 3 5.6 1.1 8.8 3 4.7 1 7.6 1.9 33 13 28 300 1.7 0 1.8 1.6 12/31/2005 20:30:00 5.1 1.1 7.6 1.5 4.8 1.1 7.2 1.9 3.9 1.1 6.5 1.5 34 17 31 300 1.7 0 1.8 1.6 12/31/2005 20:40:00 4.1 1.3 8 1.1 4 1.2 7.6 1.1 3.3 1 6.1 1.1 46 17 26 300 1.5 0 1.8 1.4 12/31/2005 20:50:00 1.7 0.9 3.8 0.4 1.7 0.9 3.8 0.4 1.8 0.6 3.8 0.4 95 49 66 300 -0.6 1.1 1.6 -1.9 12/31/2005 21:00:00 0.8 0.5 1.9 0.4 0.8 0.4 1.9 0.4 1.1 0.4 1.9 0.4 158 53 177 300 -2.2 0 -1.9 -2.4 12/31/2005 21:10:00 1.5 1 3.8 0.4 1.5 1 3.4 0.4 1.1 0.7 3 0.4 76 61 3 300 -2.1 0 -1.9 -2.4 12/31/2005 21:20:00 3.9 0.9 6.1 1.9 3.7 1 6.1 1.9 3 1 5.7 1.1 40 10 17 300 -0.5 0.9 0.7 -1.9 12/31/2005 21:30:00 4.9 1 8 2.3 4.7 1.1 7.6 1.5 4 0.9 7.2 1.5 39 13 23 300 1 0.1 1.4 0.7 12/31/2005 21:40:00 5.3 1.5 9.5 2.3 5.1 1.5 9.1 1.5 4.1 1.5 9.1 1.1 42 16 31 300 1.2 0 1.4 1.1 12/31/2005 21:50:00 6 1.2 8.4 2.3 5.6 1.2 8.8 2.3 4.6 1.2 9.1 1.9 36 13 30 300 1.3 0 1.4 1.4 12/31/2005 22:00:00 5.8 1.4 9.5 2.6 5.4 1.3 8.8 1.9 4.5 1.3 8.4 1.9 33 18 13 300 1.5 0 1.8 1.4 12/31/2005 22:10:00 4.9 1.4 8.4 1.5 4.6 1.3 8.4 1.5 4 1.2 6.8 0.7 40 21 31 300 1.7 0 1.8 1.6 12/31/2005 22:20:00 4.1 1 7.2 1.5 3.9 1.1 7.2 1.1 3.1 1 5.7 0.7 42 22 23 300 1.8 0 1.8 1.8 12/31/2005 22:30:00 4 1.3 7.2 0.7 3.9 1.2 7.2 1.1 3.1 1.2 7.2 0.7 44 20 22 300 1.5 0.4 1.8 0.7 12/31/2005 22:40:00 3.4 1 5.7 0.7 3.3 1.1 5.7 0.7 2.3 0.9 4.9 0.4 47 20 50 300 0.8 0.2 1.4 0.2 12/31/2005 22:50:00 4.2 1.5 7.6 0.4 4 1.5 7.6 0.4 3 1.2 6.8 0.7 35 22 59 300 0.9 0.5 1.6 0.2 12/31/2005 23:00:00 4.8 1.2 8 1.9 4.5 1.2 7.6 1.9 3.7 1.1 6.8 1.5 36 14 28 300 1.7 0 1.8 1.6 12/31/2005 23:10:00 5.8 1.3 9.9 2.3 5.3 1.2 8.8 1.5 4.3 1 7.6 1.5 31 13 29 300 1.8 0 1.8 1.8 12/31/2005 23:20:00 5.4 1.4 9.1 1.9 5.2 1.5 9.5 1.9 4.2 1.3 8 1.5 39 15 36 300 2 0 2.1 1.8 12/31/2005 23:30:00 4.4 1.2 8 1.5 4.2 1.3 7.6 1.5 3.5 1.1 7.6 1.1 44 20 50 300 2 0 2.1 1.8 12/31/2005 23:40:00 3.7 1.1 6.8 1.1 3.6 1.2 6.8 1.1 2.9 1.1 6.5 0.7 49 23 47 300 1.7 0.2 2.1 1.4 12/31/2005 23:50:00 2.8 1.2 6.1 0.4 2.7 1.2 6.5 0.4 2.3 0.9 5.7 0.4 77 53 72 300 1.2 0.6 1.6 -0.5 01/01/2006 00:00:00 2.5 0.5 3.8 1.1 2.5 0.5 3.8 1.1 2.4 0.5 4.2 1.1 137 19 130 300 -1.7 0.4 -0.5 -2.1 01/01/2006 00:10:00 1.7 0.5 3.4 0.4 1.7 0.5 3 0.4 1.6 0.4 2.6 0.7 107 27 126 300 -2.1 0 -2.1 -2.4 01/01/2006 00:20:00 1.1 0.6 2.3 0.4 1.1 0.6 2.3 0.4 1.4 0.4 2.3 0.4 130 32 89 300 -2.4 0 -2.1 -2.6 01/01/2006 00:30:00 1 0.6 2.6 0.4 1 0.6 2.6 0.4 1.2 0.4 2.3 0.7 166 26 233 300 -2.5 0 -2.4 -2.6 01/01/2006 00:40:00 2.6 0.4 3 1.1 2.5 0.4 3 1.1 2.5 0.4 3.4 1.5 243 5 244 300 -2.6 0 -2.4 -2.6 01/01/2006 00:50:00 0.7 0.5 2.3 0.4 0.7 0.4 1.9 0.4 0.9 0.5 2.3 0.4 313 56 249 300 -2.2 0.2 -1.9 -2.6 01/01/2006 01:00:00 0.9 0.6 3 0.4 0.8 0.6 3 0.4 0.5 0.3 1.9 0.4 33 26 60 300 -2.1 0 -1.9 -2.1 01/01/2006 01:10:00 0.7 0.6 2.3 0.4 0.7 0.6 2.3 0.4 1.3 0.7 2.6 0.4 282 98 226 300 -2 0 -1.9 -2.1 01/01/2006 01:20:00 0.6 0.4 1.9 0.4 0.6 0.4 1.9 0.4 0.8 0.5 2.3 0.4 83 82 23 300 -2.4 0.1 -2.1 -2.6 01/01/2006 01:30:00 1.8 0.9 4.2 0.4 1.7 0.9 4.6 0.4 1.1 0.6 2.6 0.4 59 47 35 300 -2.3 0 -2.1 -2.6 01/01/2006 01:40:00 3 0.8 4.9 1.1 3 0.8 4.9 1.1 2.4 0.6 4.2 0.7 52 10 70 300 -2.2 0 -2.1 -2.4 01/01/2006 01:50:00 2.9 0.6 4.6 0.7 2.9 0.7 4.6 0.7 2.1 0.5 3.8 0.7 54 11 50 300 -1.7 0.3 -1.2 -2.1 01/01/2006 02:00:00 1.4 0.6 3 0.4 1.4 0.6 3.4 0.4 1.2 0.6 3 0.4 83 39 97 300 -2.1 0.2 -1.4 -2.6 01/01/2006 02:10:00 1.3 0.7 4.6 0.4 1.2 0.7 4.2 0.4 1.1 0.4 2.6 0.4 66 20 34 300 -2.6 0 -2.4 -2.6 01/01/2006 02:20:00 0.5 0.2 1.5 0.4 0.4 0.2 1.5 0.4 0.9 0.4 1.9 0.4 112 39 57 300 -2.6 0 -2.6 -2.8 01/01/2006 02:30:00 1.6 0.8 3.4 0.4 1.6 0.8 3 0.4 0.5 0.2 1.1 0.4 48 15 43 300 -2.6 0 -2.6 -2.8 01/01/2006 02:40:00 2.7 0.4 3.4 1.5 2.3 0.4 3.4 1.1 0.9 0.5 2.3 0.4 36 6 43 300 -2.5 0 -2.4 -2.6 01/01/2006 02:50:00 0.8 0.7 3 0.4 0.7 0.5 2.6 0.4 1 0.5 1.9 0.4 70 58 28 300 -2.3 0 -2.1 -2.6 01/01/2006 03:00:00 0.5 0.3 2.3 0.4 0.5 0.3 2.3 0.4 1.2 0.5 1.9 0.4 137 72 82 300 -2.3 0 -2.1 -2.6 01/01/2006 03:10:00 0.5 0.3 1.9 0.4 0.5 0.3 1.9 0.4 1 0.7 2.3 0.4 90 82 7 300 -2.1 0 -2.1 -2.4 01/01/2006 03:20:00 1 0.6 2.6 0.4 1 0.7 2.6 0.4 1.8 0.6 3 0.4 143 58 191 300 -2.3 0 -2.1 -2.6 01/01/2006 03:30:00 1 0.6 2.6 0.4 1 0.6 3.4 0.4 1.8 0.7 3 0.4 245 69 208 300 -2.2 0 -2.1 -2.4 01/01/2006 03:40:00 0.7 0.5 2.3 0.4 0.6 0.5 2.3 0.4 0.5 0.3 1.9 0.4 324 61 37 300 -2.1 0 -1.9 -2.4 01/01/2006 03:50:00 1.1 0.5 2.3 0.4 1 0.5 2.6 0.4 1 0.7 2.6 0.4 92 51 67 300 -2.1 0 -2.1 -2.4 01/01/2006 04:00:00 0.8 0.6 2.6 0.4 0.8 0.5 2.3 0.4 1.8 0.5 3 0.4 185 43 189 300 -2.2 0 -2.1 -2.6 01/01/2006 04:10:00 1.2 0.8 2.6 0.4 1.2 0.8 2.6 0.4 2.1 0.3 2.6 1.1 215 16 215 300 -2.1 0 -2.1 -2.4 01/01/2006 04:20:00 0.8 0.5 2.3 0.4 0.7 0.5 1.9 0.4 1.2 0.5 2.3 0.4 236 47 222 300 -2.1 0 -1.9 -2.4 01/01/2006 04:30:00 0.4 0.2 2.3 0.4 0.4 0.2 2.3 0.4 1 0.4 1.9 0.4 323 94 33 300 -2.1 0 -2.1 -2.4 01/01/2006 04:40:00 0.5 0.3 1.5 0.4 0.5 0.3 1.5 0.4 1.5 0.3 1.9 0.7 206 23 208 300 -2.2 0 -2.1 -2.6 01/01/2006 04:50:00 0.8 0.4 1.9 0.4 0.9 0.6 2.3 0.4 1.3 0.4 2.3 0.4 210 17 193 300 -2.5 0 -2.1 -2.8 01/01/2006 05:00:00 1.3 0.6 2.6 0.4 1.3 0.7 3 0.4 1.4 0.6 2.6 0.4 208 13 215 300 -2.7 0 -2.6 -3 01/01/2006 05:10:00 1.5 0.4 2.3 0.4 1.6 0.5 2.3 0.4 1.4 0.6 2.3 0.4 212 11 220 300 -2.8 0 -2.6 -3 01/01/2006 05:20:00 1 0.5 1.9 0.4 0.9 0.5 1.9 0.4 1 0.5 1.9 0.4 224 8 237 300 -2.9 0 -2.6 -3 01/01/2006 05:30:00 1.1 0.7 2.3 0.4 1 0.7 2.3 0.4 1.3 0.6 2.6 0.4 232 7 223 300 -2.9 0 -2.8 -3 01/01/2006 05:40:00 1.3 0.7 2.6 0.4 1.3 0.7 2.3 0.4 1.4 0.6 2.3 0.4 222 10 223 300 -3.3 0.1 -2.8 -3.5 01/01/2006 05:50:00 1.1 0.6 2.3 0.4 1 0.6 2.3 0.4 1.2 0.7 2.6 0.4 217 21 184 300 -3.2 0 -3.3 -3.5 01/01/2006 06:00:00 0.4 0 0.7 0.4 0.4 0 0.4 0.4 0.6 0.3 1.5 0.4 302 82 226 300 -3.3 0 -3 -3.5 01/01/2006 06:10:00 1 0.6 3.4 0.4 0.9 0.6 3.4 0.4 0.8 0.4 2.3 0.4 0 29 27 300 -3.5 0 -3.5 -3.5 01/01/2006 06:20:00 2 0.6 3.4 0.4 1.8 0.6 3.4 0.4 1.2 0.5 3.4 0.4 35 14 15 300 -3.4 0.2 -2.8 -3.5 01/01/2006 06:30:00 0.6 0.5 2.6 0.4 0.6 0.5 2.3 0.4 1.5 0.8 3 0.4 122 51 192 300 -3 0.1 -2.6 -3 01/01/2006 06:40:00 2.3 0.3 3 1.5 2.5 0.2 3 1.9 2.2 0.5 3.4 1.1 218 9 225 300 -3.1 0 -2.8 -3.3 01/01/2006 06:50:00 2.6 0.3 3 1.5 2.5 0.3 3 1.5 1.9 0.4 2.6 1.1 231 7 226 300 -3.3 0 -3.3 -3.3 01/01/2006 07:00:00 1.3 0.4 2.6 0.4 1.3 0.4 2.3 0.4 1 0.5 1.9 0.4 234 15 245 300 -3.2 0 -3 -3.7 01/01/2006 07:10:00 1.2 0.4 1.9 0.4 1.1 0.4 1.9 0.4 0.7 0.3 1.5 0.4 228 3 227 300 -3.3 0 -3.3 -3.5 01/01/2006 07:20:00 1.5 0.3 2.3 0.7 1.4 0.2 1.9 0.7 1.1 0.3 1.9 0.4 232 3 233 300 -3.2 0 -3 -3.3 01/01/2006 07:30:00 1.6 0.4 2.6 0.7 1.6 0.4 2.6 0.7 1.4 0.4 2.3 0.7 223 5 218 300 -3.2 0 -3 -3.5 01/01/2006 07:40:00 2.5 0.3 3.4 1.5 2.4 0.3 3.4 1.5 1.8 0.3 2.6 0.7 241 7 231 300 -3.4 0 -3.3 -3.7 01/01/2006 07:50:00 1.7 0.6 3 0.4 1.5 0.6 2.6 0.4 1.3 0.7 2.6 0.4 245 9 237 300 -3.4 0 -3.3 -3.7 01/01/2006 08:00:00 0.4 0.2 1.5 0.4 0.4 0.2 1.1 0.4 0.7 0.4 2.3 0.4 266 5 246 300 -3.5 0.2 -3 -3.9 01/01/2006 08:10:00 0.4 0.2 1.5 0.4 0.4 0.1 1.5 0.4 0.4 0.2 1.1 0.4 253 58 349 300 -3.8 0 -3.5 -4.4 01/01/2006 08:20:00 0.4 0.2 1.5 0.4 0.4 0.1 1.1 0.4 0.5 0.2 1.5 0.4 158 43 155 300 -3.9 0 -3.7 -4.4 01/01/2006 08:30:00 0.6 0.4 2.3 0.4 0.5 0.4 2.3 0.4 0.5 0.3 1.9 0.4 63 24 61 300 -3.8 0 -3.7 -4.4 01/01/2006 08:40:00 1.2 0.5 2.3 0.4 1.2 0.5 2.3 0.4 1.2 0.3 2.3 0.4 103 27 70 300 -3.7 0 -3.5 -4.2 01/01/2006 08:50:00 1.3 0.5 3 0.4 1.3 0.5 2.6 0.4 1 0.4 1.9 0.4 70 18 57 300 -3.6 0.1 -3.5 -3.9 01/01/2006 09:00:00 1 0.5 2.6 0.4 0.9 0.5 2.6 0.4 0.6 0.3 1.5 0.4 81 17 67 300 -3.8 0 -3.5 -4.2 01/01/2006 09:10:00 0.7 0.4 2.6 0.4 0.6 0.4 2.3 0.4 1.1 0.5 1.9 0.4 146 35 109 300 -3.8 0 -3.5 -4.4 01/01/2006 09:20:00 0.4 0.1 1.1 0.4 0.4 0.2 1.1 0.4 1 0.3 1.9 0.4 173 19 211 300 -4 0 -3.7 -4.4 01/01/2006 09:30:00 0.9 0.7 3.4 0.4 0.8 0.6 3 0.4 0.6 0.4 2.3 0.4 67 39 45 300 -4.2 0.1 -3.9 -4.6 01/01/2006 09:40:00 2 0.6 3.4 0.7 1.9 0.6 3.4 0.4 1.6 0.5 3 0.4 64 28 66 300 -4.2 0.2 -3.7 -4.8 01/01/2006 09:50:00 1.1 0.6 2.6 0.4 1.2 0.7 3 0.4 2 0.6 2.6 0.4 184 45 192 300 -4 0.1 -3.7 -4.4 01/01/2006 10:00:00 1.8 0.3 3 1.1 1.9 0.5 3 1.1 1.8 0.5 2.6 0.7 222 12 216 300 -4.3 0 -3.9 -4.4 01/01/2006 10:10:00 1.1 0.4 1.9 0.4 1.1 0.4 1.9 0.4 1.3 0.4 1.9 0.4 239 9 237 300 -4.3 0 -4.2 -4.4 01/01/2006 10:20:00 1.1 0.4 1.9 0.4 1.3 0.3 1.9 0.7 0.9 0.3 1.5 0.4 212 8 226 300 -4.3 0 -4.4 -4.4 01/01/2006 10:30:00 1.2 0.4 2.3 0.4 1.4 0.4 2.3 0.4 1 0.4 1.9 0.4 212 9 220 300 -4.3 0 -4.4 -4.4 01/01/2006 10:40:00 0.6 0.4 1.9 0.4 0.6 0.4 1.9 0.4 0.6 0.4 1.9 0.4 158 43 123 300 -4.3 0 -4.2 -4.4 01/01/2006 10:50:00 1 0.7 3 0.4 1 0.8 2.6 0.4 0.9 0.6 2.6 0.4 70 20 84 300 -3.9 0.1 -3.7 -4.4 01/01/2006 11:00:00 0.4 0 0.7 0.4 0.4 0 0.4 0.4 0.4 0 0.7 0.4 48 0 46 300 -3.6 0.1 -3.5 -3.9 01/01/2006 11:10:00 0.9 0.5 1.9 0.4 1 0.5 1.9 0.4 0.8 0.4 1.9 0.4 68 12 80 300 -3.3 0 -3 -3.5 01/01/2006 11:20:00 2 0.5 3 0.7 2 0.5 3 0.7 1.9 0.4 3 0.7 83 9 97 300 -3.1 0.1 -2.8 -3.3 01/01/2006 11:30:00 1.9 0.3 2.3 1.1 2 0.3 2.6 1.1 1.6 0.2 2.3 1.1 80 6 84 300 -2.8 0.2 -2.6 -3.3 01/01/2006 11:40:00 1.2 0.4 1.9 0.4 1.3 0.4 2.3 0.4 1.1 0.3 1.5 0.4 76 17 59 300 -2.6 0 -2.6 -2.8 01/01/2006 11:50:00 0.9 0.5 2.3 0.4 0.9 0.6 2.3 0.4 0.9 0.5 2.3 0.4 106 15 109 300 -2.8 0.1 -2.6 -3.3 01/01/2006 12:00:00 0.4 0 0.7 0.4 0.4 0.1 0.7 0.4 0.5 0.3 1.5 0.4 310 127 21 300 -3.1 0 -2.8 -3.3 01/01/2006 12:10:00 0.5 0.4 1.9 0.4 0.6 0.4 1.9 0.4 1.1 0.4 1.9 0.4 128 47 164 300 -3.1 0 -3 -3.5 01/01/2006 12:20:00 1.7 0.7 2.6 0.4 1.7 0.7 2.6 0.4 1.8 0.6 2.6 0.4 158 3 158 300 -3.2 0 -3 -3.5 01/01/2006 12:30:00 0.5 0.3 1.5 0.4 0.6 0.3 1.5 0.4 0.7 0.3 1.5 0.4 167 13 155 300 -3.1 0.1 -2.8 -3.5 01/01/2006 12:40:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.5 0.3 1.5 0.4 183 0 300 300 -2.9 0 -2.8 -3.5 01/01/2006 12:50:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.9 0.4 1.5 0.4 103 45 300 300 -2.8 0 -2.6 -2.8 01/01/2006 13:00:00 0.4 0.2 1.1 0.4 0.5 0.3 1.1 0.4 0.5 0.2 1.1 0.4 157 41 137 300 -2.6 0 -2.6 -3 01/01/2006 13:10:00 0.4 0 0.4 0.4 0.4 0 0.7 0.4 0.4 0.2 1.1 0.4 193 14 300 300 -2.6 0 -2.6 -3 01/01/2006 13:20:00 0.4 0.1 1.1 0.4 0.4 0.2 1.1 0.4 0.5 0.3 1.5 0.4 170 4 181 300 -2.5 0 -2.4 -2.8 01/01/2006 13:30:00 1.2 0.4 1.9 0.4 1.5 0.4 2.3 0.4 1.2 0.3 1.9 0.4 195 12 182 300 -2.5 0 -2.4 -2.6 01/01/2006 13:40:00 1.5 0.2 1.9 0.7 1.4 0.2 1.9 0.7 1.2 0.4 1.9 0.4 230 13 212 300 -2.5 0 -2.4 -2.8 01/01/2006 13:50:00 0.7 0.4 1.5 0.4 0.7 0.4 1.5 0.4 0.8 0.3 1.5 0.4 254 3 246 300 -2.6 0 -2.6 -2.8 01/01/2006 14:00:00 0.4 0 0.4 0.4 0.4 0 0.4 0.4 0.5 0.2 1.1 0.4 256 0 300 300 -2.5 0.1 -2.4 -2.8 01/01/2006 14:10:00 0.5 0.3 1.1 0.4 0.7 0.4 1.5 0.4 0.6 0.3 1.5 0.4 222 21 203 300 -2.4 0 -2.4 -2.8 01/01/2006 14:20:00 0.5 0.2 1.1 0.4 0.5 0.2 1.1 0.4 0.7 0.3 1.5 0.4 212 0 211 300 -2.5 0 -2.4 -2.6 01/01/2006 14:30:00 0.6 0.4 1.9 0.4 0.7 0.5 2.3 0.4 1.2 0.5 2.3 0.4 212 0 213 300 -2.5 0 -2.4 -2.6 01/01/2006 14:40:00 1.1 0.3 1.5 0.4 1.5 0.4 2.3 0.4 1.3 0.5 2.3 0.4 212 5 211 300 -2.5 0 -2.4 -2.6 01/01/2006 14:50:00 0.7 0.3 1.1 0.4 0.6 0.2 1.1 0.4 0.7 0.3 1.5 0.4 248 9 239 300 -2.6 0 -2.4 -2.6 01/01/2006 15:00:00 0.5 0.2 1.1 0.4 0.5 0.3 1.5 0.4 0.4 0.1 0.7 0.4 320 66 47 300 -2.6 0 -2.6 -2.6 01/01/2006 15:10:00 0.4 0.2 1.1 0.4 0.5 0.2 1.1 0.4 0.6 0.4 1.9 0.4 85 39 48 300 -2.6 0 -2.6 -2.8 01/01/2006 15:20:00 0.4 0.1 1.1 0.4 0.4 0.1 1.1 0.4 0.4 0 0.4 0.4 128 17 131 300 -2.8 0 -2.8 -2.8 01/01/2006 15:30:00 0.8 0.5 2.3 0.4 0.8 0.5 2.3 0.4 0.8 0.5 2.3 0.4 110 20 134 300 -2.9 0 -2.8 -3 01/01/2006 15:40:00 1.2 0.8 3.8 0.4 1.2 0.8 3.4 0.4 0.8 0.4 2.3 0.4 86 17 65 300 -2.9 0 -2.6 -3 01/01/2006 15:50:00 2.3 0.4 3.4 1.5 2.4 0.4 3.4 1.5 1.5 0.4 2.3 0.7 70 6 43 300 -3 0 -2.8 -3.3 01/01/2006 16:00:00 2.2 0.5 3.4 1.1 2.2 0.4 3.4 1.1 0.9 0.4 1.9 0.4 74 8 61 300 -3 0 -2.8 -3 01/01/2006 16:10:00 1.7 0.4 2.3 0.7 1.8 0.4 2.6 0.4 1.2 0.5 2.3 0.4 84 9 85 300 -2.9 0.1 -2.8 -3 01/01/2006 16:20:00 2 0.4 3.4 1.5 2.1 0.4 3.4 1.1 1.5 0.2 2.3 1.1 80 16 45 300 -3.1 0 -3 -3.5 01/01/2006 16:30:00 3.3 0.3 4.2 2.3 3.3 0.3 4.2 2.3 2.2 0.4 3 0.7 46 4 38 300 -3.1 0 -3 -3.3 01/01/2006 16:40:00 2.7 0.6 4.2 1.1 2.6 0.6 3.8 0.7 1.2 0.8 3 0.4 50 7 48 300 -3.1 0 -3 -3.3 01/01/2006 16:50:00 2.7 0.7 4.6 1.1 2.7 0.7 4.6 0.7 1.4 0.8 3 0.4 47 10 35 300 -3.4 0 -3.3 -3.5 01/01/2006 17:00:00 3.8 0.5 4.9 2.6 3.5 0.6 5.3 1.9 2.7 0.5 4.6 1.5 32 9 36 300 -2.9 0.5 -1.9 -3.7 01/01/2006 17:10:00 4 0.8 6.5 1.9 3.7 0.9 6.5 1.9 2.8 0.7 4.9 1.1 36 13 52 300 -1.2 0.3 -0.7 -1.9 01/01/2006 17:20:00 2.5 1 4.6 0.4 2.3 0.9 4.6 0.4 1.3 0.8 3.8 0.4 39 29 46 300 -2.3 0.7 -0.7 -3.3 01/01/2006 17:30:00 3.6 0.8 6.1 1.9 3.4 0.9 5.7 1.1 2.6 0.8 4.9 1.1 39 15 34 300 -2.1 0.6 -1.2 -3.3 01/01/2006 17:40:00 2.1 1 4.9 0.4 2 1 5.3 0.4 1.5 0.6 3.4 0.4 55 22 359 300 -2.1 0.3 -1.2 -2.6 01/01/2006 17:50:00 2.5 0.5 4.2 1.1 2.5 0.5 4.2 1.1 2.1 0.5 4.2 1.1 70 9 57 300 -2.3 0.2 -1.9 -2.8 01/01/2006 18:00:00 3 0.4 4.2 1.9 3 0.5 4.2 1.1 1.9 0.7 3.4 0.4 55 12 27 300 -2.5 0.1 -2.1 -3 01/01/2006 18:10:00 1.6 0.8 3.8 0.4 1.6 0.8 3 0.4 1.4 0.8 2.6 0.4 99 58 39 300 -2.6 0.2 -2.1 -3 01/01/2006 18:20:00 1.4 0.5 2.6 0.4 1.4 0.5 2.6 0.4 1 0.7 2.3 0.4 84 30 149 300 -3.1 0 -2.8 -3.5 01/01/2006 18:30:00 1.9 1 4.6 0.4 1.8 1 4.6 0.4 0.8 0.6 3.8 0.4 39 21 37 300 -3.2 0 -3 -3.3 01/01/2006 18:40:00 3.5 0.7 5.7 1.5 3.3 0.7 4.9 1.1 2.6 0.6 4.6 1.1 38 10 20 300 -2.3 0.6 -1.2 -3.5 01/01/2006 18:50:00 3.6 0.8 6.1 1.9 3.5 0.8 5.7 1.5 2.7 0.8 5.7 1.1 42 12 36 300 -0.3 0.6 0.4 -1.4 01/01/2006 19:00:00 2.6 1 6.1 0.4 2.5 1 6.1 0.4 2 0.7 4.2 0.7 61 28 34 300 -1 0.7 0.4 -1.9 01/01/2006 19:10:00 1.9 0.6 4.6 0.4 1.8 0.7 4.9 0.4 1.6 0.5 3 0.4 64 19 41 300 -2.3 0.2 -1.9 -2.6 01/01/2006 19:20:00 2.3 0.9 4.9 0.4 2.3 0.8 4.9 0.4 1.6 0.6 3.8 0.4 59 22 38 300 -2.8 0 -2.4 -2.8 01/01/2006 19:30:00 2.8 0.8 5.7 0.7 2.7 0.8 5.7 0.4 2.2 0.8 4.6 0.7 57 19 48 300 -1.9 0.1 -1.4 -2.4 01/01/2006 19:40:00 2.3 0.6 3.8 0.7 2.3 0.6 4.2 0.7 1.9 0.6 4.2 0.4 66 13 40 300 -0.8 0.4 -0.1 -1.7 01/01/2006 19:50:00 1.5 0.6 3.4 0.4 1.4 0.7 3.4 0.4 1.3 0.6 2.6 0.4 82 27 87 300 -1.4 0.9 0.2 -2.6 01/01/2006 20:00:00 1.5 0.7 3.8 0.4 1.5 0.7 3.8 0.4 1.5 0.5 2.6 0.4 92 22 80 300 -2.9 0.1 -2.6 -3 01/01/2006 20:10:00 1.4 0.5 2.6 0.4 1.5 0.6 3 0.4 2 0.4 3 1.1 190 20 140 300 -2.9 0 -2.8 -3 01/01/2006 20:20:00 1.3 0.4 2.3 0.4 1.7 0.4 2.6 0.7 1.5 0.5 2.6 0.4 202 6 198 300 -3 0 -2.8 -3 01/01/2006 20:30:00 1.3 0.4 1.9 0.4 1.4 0.4 2.3 0.4 1.5 0.5 2.6 0.4 209 10 210 300 -3 0 -2.8 -3 01/01/2006 20:40:00 1.7 0.4 2.6 0.4 1.7 0.5 2.3 0.4 1.5 0.4 2.3 0.4 221 15 224 300 -2.8 0 -2.6 -2.8 01/01/2006 20:50:00 1.5 0.3 2.3 0.7 1.4 0.3 2.3 0.4 1.3 0.5 2.3 0.4 231 14 237 300 -2.6 0 -2.6 -2.6 01/01/2006 21:00:00 1.4 0.7 3 0.4 1.6 1 3.4 0.4 1.6 0.8 3 0.4 209 16 213 300 -2.5 0 -2.4 -2.6 01/01/2006 21:10:00 1.9 0.5 3 0.7 1.9 0.5 3 0.4 1.8 0.5 2.6 0.7 224 9 219 300 -2.6 0 -2.6 -2.8 01/01/2006 21:20:00 2.4 0.4 3.4 1.5 2.4 0.4 3.4 1.1 1.8 0.5 2.6 0.4 228 9 233 300 -2.6 0 -2.6 -2.8 01/01/2006 21:30:00 2 0.8 3.8 0.4 2.1 0.7 3.4 0.4 2.1 0.6 3.4 0.4 213 41 97 300 -2.7 0 -2.6 -2.8 01/01/2006 21:40:00 1.9 0.4 3 0.7 1.8 0.4 3 0.7 1.6 0.7 3.8 0.7 233 11 231 300 -2.6 0 -2.4 -3 01/01/2006 21:50:00 0.8 0.5 1.9 0.4 0.7 0.5 2.3 0.4 0.8 0.5 1.9 0.4 239 21 256 300 -2.5 0 -2.4 -2.6 01/01/2006 22:00:00 1 0.4 2.3 0.4 0.9 0.4 1.9 0.4 1.1 0.4 2.3 0.4 227 24 226 300 -2.6 0 -2.4 -3 01/01/2006 22:10:00 0.9 0.5 1.9 0.4 0.8 0.5 2.3 0.4 1.2 0.5 2.3 0.4 254 56 241 300 -2.6 0 -2.6 -3 01/01/2006 22:20:00 1.5 0.8 3 0.4 1.4 0.7 3 0.4 1.9 0.4 3 0.7 246 58 227 300 -2.6 0 -2.4 -3 01/01/2006 22:30:00 1.6 0.9 5.3 0.4 1.5 0.9 4.9 0.4 1.8 0.7 3.4 0.4 246 49 349 300 -2.4 0 -2.4 -2.6 01/01/2006 22:40:00 1.2 0.7 3 0.4 1.2 0.8 3.4 0.4 1.8 0.5 3 0.7 152 64 152 300 -2.5 0 -2.4 -2.8 01/01/2006 22:50:00 1.5 0.4 2.3 0.4 1.6 0.5 3 0.4 1.7 0.6 3 0.4 211 24 218 300 -2.4 0 -2.4 -2.6 01/01/2006 23:00:00 1.1 0.6 2.3 0.4 1.1 0.6 2.3 0.4 1.3 0.6 2.6 0.4 220 8 220 300 -2.6 0 -2.4 -2.8 01/01/2006 23:10:00 1.5 1.1 4.9 0.4 1.4 1.1 4.9 0.4 1.7 0.7 3 0.4 281 90 37 300 -2.3 0 -2.1 -2.8 01/01/2006 23:20:00 2 0.9 4.6 0.4 2 0.8 4.9 0.4 1.7 0.6 3 0.4 87 56 352 300 -2.5 0.2 -2.1 -3 01/01/2006 23:30:00 1.5 0.6 2.6 0.4 1.6 0.6 3.4 0.4 1.7 0.5 3 0.7 136 36 140 300 -2.6 0.3 -1.9 -3 01/01/2006 23:40:00 1.1 0.7 3 0.4 1 0.7 2.6 0.4 0.9 0.6 3 0.4 68 30 32 300 -2.3 0 -2.1 -2.6 01/01/2006 23:50:00 4 1.4 8.4 1.5 3.9 1.3 8.4 1.5 3.3 1.3 7.6 0.7 44 19 57 300 -1.4 0.7 -0.3 -2.4 01/02/2006 00:00:00 4.4 1 7.2 1.9 4.1 1 7.2 1.5 3.3 1 6.5 1.5 34 15 25 300 0.5 0.2 0.9 -0.5 01/02/2006 00:10:00 5.2 1.5 9.1 1.9 4.9 1.5 8.8 1.5 4.1 1.2 7.2 0.4 39 17 25 300 1.1 0.1 1.4 0.9 01/02/2006 00:20:00 5.3 1.3 8.8 0.7 5.1 1.3 8.8 0.4 4.3 1.4 8 1.1 42 21 49 300 1.4 0 1.6 1.4 01/02/2006 00:30:00 5.1 1.3 9.1 1.5 4.9 1.3 8 1.9 4 1.3 8.4 0.7 37 19 25 300 1.5 0 1.8 1.4 01/02/2006 00:40:00 3.9 1.1 6.5 1.5 3.9 1.1 6.5 1.5 3.2 1.1 6.5 0.7 49 21 38 300 1.3 0.2 1.6 0.7 01/02/2006 00:50:00 3.3 1 4.9 1.1 3.3 1 5.3 0.7 2.6 0.9 5.3 0.4 52 17 48 300 0.5 0.1 0.7 -0.1 01/02/2006 01:00:00 2.7 0.7 4.6 0.7 2.6 0.7 4.2 0.4 1.7 0.5 3 0.4 42 16 20 300 -1.8 0.8 -0.1 -2.6 01/02/2006 01:10:00 3.4 0.7 5.3 1.9 3.2 0.6 5.3 1.5 2.7 0.7 4.9 1.5 41 13 47 300 -0.9 1 0.7 -2.4 01/02/2006 01:20:00 3.4 0.7 4.9 1.5 3.3 0.7 5.3 1.1 2.6 0.6 4.6 1.1 41 10 35 300 0.7 0 0.9 0.7 01/02/2006 01:30:00 4 0.7 5.7 2.6 3.9 0.8 5.7 2.3 3.2 0.8 5.3 1.5 38 11 16 300 1 0 1.4 0.9 01/02/2006 01:40:00 3 0.9 4.9 0.7 2.9 0.8 4.9 0.7 2.4 0.7 4.2 0.7 51 18 55 300 0.9 0.3 1.4 -0.3 01/02/2006 01:50:00 3 1.1 7.2 0.7 3 1.1 6.8 0.4 2.2 1 5.3 0.4 57 22 26 300 -1.7 0.5 -0.3 -2.1 01/02/2006 02:00:00 5.2 1.3 8.8 2.3 4.8 1.2 8.4 1.9 4 1.2 7.2 0.7 35 17 18 300 0.2 0.6 1.1 -1.2 01/02/2006 02:10:00 4.6 1 7.6 1.9 4.4 1 7.2 1.5 3.6 1 6.5 0.7 37 15 37 300 1 0 1.4 0.9 01/02/2006 02:20:00 3.8 1.1 6.5 1.5 3.7 1.1 6.5 1.1 2.9 1 6.1 0.7 47 17 53 300 0.9 0 1.4 0.7 01/02/2006 02:30:00 3.4 1 6.1 1.1 3.3 1 6.1 1.1 2.8 0.9 4.9 0.7 38 18 29 300 0.7 0 0.9 0.7 01/02/2006 02:40:00 4.5 0.7 6.5 3 4.2 0.8 6.5 1.9 3.5 0.7 5.7 1.9 36 10 42 300 0.8 0 0.9 0.7 01/02/2006 02:50:00 4.4 0.9 6.8 1.9 4.2 1 6.8 1.9 3.3 1 5.3 1.1 39 14 46 300 0.9 0 0.9 0.7 01/02/2006 03:00:00 3.7 0.9 6.5 1.5 3.4 0.9 6.5 1.9 2.6 0.9 5.7 0.7 40 13 57 300 0.7 0 0.9 0.7 01/02/2006 03:10:00 3.9 0.7 5.7 1.9 3.8 0.8 5.7 1.1 2.8 0.8 4.9 0.7 44 11 45 300 0.2 0.1 0.7 0.2 01/02/2006 03:20:00 2.8 1.1 6.1 0.4 2.7 1.1 6.1 0.4 2.1 0.8 4.2 0.4 48 21 43 300 -0.1 0.3 0.4 -0.7 01/02/2006 03:30:00 2.5 1.1 4.9 0.4 2.4 1.1 4.9 0.4 2 0.9 4.9 0.4 30 18 48 300 -0.5 0.3 0.2 -0.7 01/02/2006 03:40:00 4.3 1.2 7.2 2.3 4.1 1.2 7.6 1.9 3.3 1.1 7.2 1.1 36 13 20 300 0.1 0 0.2 0.2 01/02/2006 03:50:00 5.1 1 8 3 4.7 1 8 2.3 4 1 6.5 1.5 32 13 8 300 0.3 0 0.4 0.2 01/02/2006 04:00:00 4.8 1.2 8 1.9 4.6 1.2 8 1.5 3.9 1.1 6.8 1.1 32 11 36 300 0.4 0 0.7 0.2 01/02/2006 04:10:00 5.5 1.2 8.8 2.6 5.1 1.1 8.8 2.6 4.2 1.2 7.6 1.5 34 13 47 300 0.5 0 0.7 0.2 01/02/2006 04:20:00 5.7 1.2 8.8 3 5.2 1.1 8.8 2.6 4.6 1.2 8 1.5 31 12 46 300 0.4 0 0.7 0.2 01/02/2006 04:30:00 7 1.5 10.3 3.4 6.4 1.4 9.5 3.4 5.5 1.3 9.1 2.3 25 14 16 300 0.4 0 0.4 0.2 01/02/2006 04:40:00 6.5 1.5 10.3 3 6.1 1.5 11.1 2.6 5 1.3 8.8 2.6 22 14 7 300 0.2 0 0.7 0.2 01/02/2006 04:50:00 7 1.3 9.9 3.8 6.4 1.2 9.1 3 5.3 1.1 8.8 2.6 25 12 22 300 0.1 0 0.4 -0.1 01/02/2006 05:00:00 7.1 1.4 9.9 2.6 6.5 1.3 9.9 3 5.4 1.1 9.1 2.6 27 13 35 300 -0.2 0 0.2 -0.3 01/02/2006 05:10:00 6.4 1.3 10.7 3 6 1.2 9.5 2.6 5 1.1 8.4 2.3 30 15 40 300 -0.2 0 -0.1 -0.3 01/02/2006 05:20:00 5.2 1.3 8.8 2.3 4.8 1.3 8.8 1.9 3.9 1.2 7.2 1.5 32 15 37 300 -0.1 0 -0.1 -0.1 01/02/2006 05:30:00 5.6 1.2 9.1 2.3 5.2 1.2 8.8 2.3 4.4 1.2 7.6 1.1 27 15 23 300 -0.2 0 -0.1 -0.3 01/02/2006 05:40:00 3.8 0.9 6.8 1.5 3.7 0.9 5.7 1.5 3.2 0.9 5.7 1.5 40 17 22 300 -0.4 0 -0.1 -0.5 01/02/2006 05:50:00 4.8 1 8 2.6 4.5 0.9 7.2 2.3 3.7 0.9 6.8 1.9 32 12 28 300 -0.5 0 -0.5 -0.5 01/02/2006 06:00:00 5.9 1 9.1 3.8 5.3 1 8.4 3 4.4 0.9 7.2 2.6 24 10 21 300 -0.5 0 -0.5 -0.5 01/02/2006 06:10:00 5 1.2 8 2.3 4.7 1.2 8 1.9 3.9 1.1 7.2 0.7 25 14 31 300 -0.3 0 -0.3 -0.5 01/02/2006 06:20:00 4.3 1.1 6.8 1.9 3.9 1.1 6.5 1.5 3.5 0.9 6.1 1.1 30 13 35 300 -0.5 0 -0.3 -0.5 01/02/2006 06:30:00 5 1.1 8 3 4.6 1.1 8 2.3 3.9 1.1 7.2 1.5 29 13 13 300 -0.5 0 -0.5 -0.7 01/02/2006 06:40:00 5.5 1.4 10.7 2.3 5.1 1.3 9.1 2.6 4.3 1.2 8.4 1.9 29 15 24 300 -0.6 0 -0.5 -0.7 01/02/2006 06:50:00 5.6 1.2 9.1 2.6 5.1 1.2 8 2.3 4.5 1.2 8.8 1.5 30 13 18 300 -0.5 0 -0.5 -0.7 01/02/2006 07:00:00 6.4 1.2 9.5 3.4 5.9 1.1 9.1 2.6 5 1 8.4 2.3 29 12 21 300 -0.5 0 -0.5 -0.7 01/02/2006 07:10:00 5.6 1.3 9.1 2.6 5.3 1.2 8.8 2.3 4.4 1.2 7.6 1.5 34 15 41 300 -0.6 0 -0.5 -0.7 01/02/2006 07:20:00 6.9 1.2 9.9 3.8 6.2 1.1 9.1 3.8 5.3 1.1 8 2.6 28 11 26 300 -0.7 0 -0.5 -0.7 01/02/2006 07:30:00 7.8 1.2 10.7 4.6 7 1.3 10.3 3.8 5.7 1.3 9.9 3 21 10 18 300 -0.8 0 -0.5 -0.7 01/02/2006 07:40:00 7.6 1.5 10.7 3.8 7.1 1.6 11.1 3.4 5.9 1.5 9.9 2.6 17 10 20 300 -1 0 -0.7 -1 01/02/2006 07:50:00 6.7 1.2 9.5 3.8 6.1 1.2 9.1 3.4 5 1.1 8 2.3 23 12 14 300 -1.1 0 -0.7 -1.2 01/02/2006 08:00:00 7.4 1.1 9.9 4.6 6.7 1.2 9.9 3.4 5.3 1.3 9.9 2.3 21 11 10 300 -1 0 -0.7 -1.2 01/02/2006 08:10:00 7.2 1.1 9.9 4.2 6.9 1.2 10.3 3.8 5.5 1.2 9.5 1.9 15 10 17 300 -1 0 -1 -1.2 01/02/2006 08:20:00 7.1 1.2 10.3 3 6.3 1.2 10.3 3 5.1 1.1 8.8 2.6 25 12 19 300 -1 0 -1 -1.4 01/02/2006 08:30:00 6.2 1.5 9.5 2.3 5.6 1.3 9.1 2.3 4.5 1.3 8 1.1 26 13 22 300 -1.1 0 -1 -1.2 01/02/2006 08:40:00 5.3 1.2 8 2.3 4.9 1.2 8 1.9 4 1.2 6.8 1.1 31 15 45 300 -1.2 0 -1 -1.4 01/02/2006 08:50:00 3.7 1.4 7.2 1.1 3.5 1.3 7.2 0.7 2.9 1.2 6.1 0.4 35 22 39 300 -1.3 0.1 -1.2 -1.4 01/02/2006 09:00:00 4.3 1.2 7.2 1.1 4.1 1.2 7.2 1.1 3.2 1 6.5 0.4 35 17 20 300 -1.4 0 -1.2 -1.4 01/02/2006 09:10:00 5.4 1.2 8.8 2.6 5 1.2 8.8 2.3 4.2 1.1 7.6 1.9 31 15 27 300 -1.4 0 -1.2 -1.4 01/02/2006 09:20:00 5.9 1 8.4 3 5.3 0.9 7.6 3 4.7 0.9 7.6 2.6 31 12 25 300 -1.4 0 -1.2 -1.4 01/02/2006 09:30:00 5.9 1.2 8.8 2.3 5.3 1.1 8.4 2.3 4.2 1 6.5 1.9 28 12 21 300 -1.6 0 -1.4 -1.4 01/02/2006 09:40:00 5.2 1.2 8 2.3 4.8 1.2 8.4 1.9 4.1 1 7.2 1.9 28 15 16 300 -1.6 0 -1.4 -1.7 01/02/2006 09:50:00 6.4 1.3 9.5 3.4 5.9 1.4 9.5 2.3 4.8 1.3 8.8 1.9 23 14 31 300 -1.7 0 -1.4 -1.9 01/02/2006 10:00:00 6.5 1.2 9.9 3.4 6 1.2 9.9 3 4.8 1.1 8.4 1.5 21 13 11 300 -1.6 0 -1.4 -1.9 01/02/2006 10:10:00 5.5 1 8.4 3 5.1 1 8.8 3 4.2 1.1 7.6 1.5 27 15 24 300 -1.6 0 -1.4 -1.7 01/02/2006 10:20:00 5 1 8 2.3 4.6 1.1 7.6 2.3 3.7 1 6.5 1.5 24 13 26 300 -1.6 0 -1.4 -1.7 01/02/2006 10:30:00 3.9 1.1 6.5 1.1 3.5 1.1 6.5 0.7 3 0.9 6.1 1.1 27 18 24 300 -1.6 0 -1.4 -1.4 01/02/2006 10:40:00 4 0.9 6.8 1.5 3.6 0.9 6.5 1.5 3 0.9 5.7 1.1 27 14 15 300 -1.6 0 -1.4 -1.7 01/02/2006 10:50:00 4 1 7.2 1.9 3.7 1 6.5 1.5 3.1 1 6.1 0.7 34 15 28 300 -1.6 0 -1.4 -1.7 01/02/2006 11:00:00 2.5 1 4.6 0.4 2.3 1 4.6 0.4 1.9 0.8 4.6 0.4 37 22 39 300 -1.8 0 -1.4 -2.1 01/02/2006 11:10:00 2.9 1 5.7 0.4 2.6 1 5.3 0.4 2.3 1 5.3 0.4 25 15 21 300 -1.7 0 -1.4 -2.1 01/02/2006 11:20:00 3.7 1 5.7 1.5 3.4 0.9 5.7 0.7 2.7 0.9 4.9 0.4 30 15 28 300 -1.7 0 -1.4 -2.1 01/02/2006 11:30:00 1.9 1.1 4.9 0.4 1.7 1.1 4.9 0.4 1.5 0.8 5.7 0.4 59 41 12 300 -1.8 0.1 -1.4 -2.1 01/02/2006 11:40:00 2.9 1 4.9 0.4 2.6 1 4.9 0.4 2.1 0.9 4.6 0.4 28 18 30 300 -2.1 0 -1.9 -2.6 01/02/2006 11:50:00 4.3 0.7 6.1 2.6 3.9 0.8 6.1 2.3 3.1 0.8 4.9 1.5 27 13 28 300 -1.7 0 -1.4 -1.9 01/02/2006 12:00:00 4.5 1 7.2 1.5 4 0.9 6.5 1.1 3.3 0.9 6.1 1.1 30 13 15 300 -1.2 0.3 -0.7 -1.9 01/02/2006 12:10:00 3.7 1.1 7.2 1.1 3.4 1 6.8 1.1 2.7 0.9 5.3 0.7 41 23 29 300 -0.7 0 -0.5 -1.2 01/02/2006 12:20:00 4.1 1.1 7.2 0.7 3.8 1.1 7.2 0.4 3 1 5.3 0.4 32 20 14 300 -0.5 0 -0.5 -1 01/02/2006 12:30:00 3.8 0.8 6.1 1.5 3.7 0.8 5.7 1.9 3.1 0.8 5.3 1.1 32 15 48 300 -0.3 0 -0.1 -0.5 01/02/2006 12:40:00 3.4 1 6.5 1.1 3.3 1 6.8 0.7 2.9 0.9 4.9 0.7 32 18 16 300 -0.2 0 -0.1 -0.3 01/02/2006 12:50:00 3.3 1.2 6.8 0.7 3.2 1.2 6.5 0.4 2.7 0.8 4.9 1.1 42 32 52 300 -0.2 0 -0.1 -0.5 01/02/2006 13:00:00 2.4 1 5.3 0.4 2.3 1 5.3 0.4 1.9 0.9 4.9 0.4 50 32 58 300 -0.1 0 0.2 -0.3 01/02/2006 13:10:00 2.6 0.8 4.9 0.7 2.5 0.9 4.6 0.4 2.2 0.9 4.6 0.4 43 19 28 300 0.1 0 0.2 -0.1 01/02/2006 13:20:00 2.7 0.9 5.7 0.7 2.6 0.9 6.1 0.4 2.3 0.8 4.2 0.4 42 22 34 300 0.1 0 0.2 -0.1 01/02/2006 13:30:00 2.7 0.8 5.7 0.7 2.6 0.8 5.3 0.4 2 0.9 4.6 0.4 43 20 45 300 0.1 0 0.2 -0.1 01/02/2006 13:40:00 2.1 0.9 4.2 0.4 1.9 0.9 3.8 0.4 1.6 0.7 3.4 0.4 43 22 49 300 0.1 0 0.4 -0.1 01/02/2006 13:50:00 2.3 0.7 4.9 0.7 2.2 0.7 4.6 0.4 1.9 0.7 3.8 0.7 52 22 49 300 0.3 0 0.4 0.2 01/02/2006 14:00:00 2.7 1.1 6.1 0.4 2.5 1.1 5.3 0.4 2 1 4.9 0.4 41 17 27 300 0.2 0 0.4 0.2 01/02/2006 14:10:00 2.9 0.8 4.9 1.1 2.7 0.8 4.9 0.7 2.4 0.8 4.6 0.7 39 19 79 300 0 0 0.2 -0.1 01/02/2006 14:20:00 3 1.2 5.7 0.4 2.8 1.2 5.7 0.4 2.3 1 5.3 0.4 33 23 48 300 -0.4 0 -0.1 -0.5 01/02/2006 14:30:00 2.5 0.8 4.6 0.4 2.3 0.8 4.2 0.4 1.8 0.7 3.8 0.4 38 24 4 300 -0.6 0 -0.5 -0.7 01/02/2006 14:40:00 1.3 0.8 3.4 0.4 1.3 0.9 3.8 0.4 1.3 0.7 3.4 0.4 65 49 35 300 -0.6 0 -0.5 -0.7 01/02/2006 14:50:00 1.7 1.2 4.9 0.4 1.6 1.2 4.9 0.4 1.3 0.9 4.2 0.4 36 30 21 300 -0.8 0 -0.7 -0.7 01/02/2006 15:00:00 2.5 0.6 4.2 1.1 2.3 0.7 4.6 1.1 1.8 0.7 3.4 0.4 36 19 43 300 -0.7 0 -0.7 -0.7 01/02/2006 15:10:00 2.3 0.8 4.6 0.4 2.1 0.8 4.6 0.4 1.9 0.7 3.8 0.7 39 15 45 300 -0.7 0 -0.5 -0.7 01/02/2006 15:20:00 3.9 0.7 6.5 1.9 3.6 0.8 5.7 1.9 2.8 0.7 5.3 1.5 33 12 24 300 -0.7 0 -0.7 -0.7 01/02/2006 15:30:00 4 0.8 6.1 1.9 3.7 0.8 6.5 1.9 3.1 0.8 5.7 1.5 35 13 25 300 -0.7 0 -0.5 -0.7 01/02/2006 15:40:00 3.8 0.9 6.1 1.5 3.6 1 6.1 1.5 2.9 0.9 4.9 0.7 37 13 28 300 -0.6 0 -0.5 -0.7 01/02/2006 15:50:00 3.5 0.9 6.8 1.5 3.4 0.9 6.8 1.1 2.8 0.9 5.3 0.4 39 14 25 300 -0.5 0 -0.5 -0.5 01/02/2006 16:00:00 3.4 1 5.3 0.7 3.1 1 5.7 0.7 2.5 1 4.6 0.4 38 16 28 300 -0.5 0 -0.5 -0.5 01/02/2006 16:10:00 3.2 0.7 4.9 1.5 3.1 0.8 5.3 1.5 2.3 0.8 4.6 0.7 43 15 39 300 -0.5 0 -0.5 -0.5 01/02/2006 16:20:00 2.3 0.8 4.6 0.4 2.1 0.8 4.2 0.4 1.7 0.6 3.4 0.4 45 19 33 300 -0.5 0 -0.5 -0.7 01/02/2006 16:30:00 2.1 0.7 3.8 0.7 1.8 0.7 3.8 0.4 1.5 0.6 3.4 0.4 29 13 36 300 -0.5 0 -0.5 -0.5 01/02/2006 16:40:00 3.6 0.8 6.1 1.9 3.2 0.9 6.1 1.5 2.6 0.7 5.7 1.1 26 10 30 300 -0.5 0 -0.5 -0.5 01/02/2006 16:50:00 4.1 0.7 5.7 2.3 3.8 0.7 6.1 1.9 3.1 0.8 5.3 1.1 29 13 35 300 -0.3 0 -0.3 -0.5 01/02/2006 17:00:00 3.8 0.8 5.7 1.5 3.6 0.8 5.7 1.1 3.1 0.9 4.9 0.7 35 15 46 300 -0.3 0 -0.3 -0.5 01/02/2006 17:10:00 4.2 0.7 5.7 2.3 3.9 0.7 5.7 1.9 3.2 0.8 5.7 1.5 33 11 26 300 -0.3 0 -0.3 -0.5 01/02/2006 17:20:00 3.9 0.9 6.8 1.9 3.8 0.9 6.8 1.9 3.1 0.9 5.7 1.1 37 13 9 300 -0.3 0 -0.3 -0.5 01/02/2006 17:30:00 4.3 0.8 6.1 1.9 3.9 0.8 6.1 1.9 3.2 1 5.7 1.1 34 9 28 300 -0.5 0 -0.5 -0.7 01/02/2006 17:40:00 3.5 0.8 5.7 1.1 3.2 0.9 5.7 1.1 2.3 0.8 4.6 0.4 29 13 29 300 -0.7 0 -0.5 -0.7 01/02/2006 17:50:00 3.3 0.8 4.9 1.5 2.9 0.8 4.9 1.1 2.5 0.8 4.6 0.7 30 13 21 300 -0.9 0 -0.7 -1 01/02/2006 18:00:00 3.9 0.8 6.1 1.5 3.6 0.8 5.7 1.1 2.9 0.8 5.3 0.7 23 11 37 300 -1 0 -0.7 -1.2 01/02/2006 18:10:00 4 0.9 6.1 1.5 3.7 1 6.5 1.1 3.1 0.9 5.7 0.7 32 18 34 300 -1 0 -0.7 -1.2 01/02/2006 18:20:00 2.8 0.9 6.1 0.7 2.6 1 6.1 0.4 1.9 0.7 4.2 0.7 43 17 47 300 -1.2 0 -0.7 -1.4 01/02/2006 18:30:00 3.8 1 6.1 1.1 3.5 1 5.7 0.7 2.7 0.9 4.6 0.4 34 15 36 300 -1.2 0 -1 -1.2 01/02/2006 18:40:00 2.8 0.8 4.9 1.1 2.6 0.9 4.6 0.7 2.1 0.9 4.6 0.4 39 15 31 300 -1.2 0.1 -1 -1.4 01/02/2006 18:50:00 3.3 0.8 4.9 1.1 2.9 0.9 4.9 0.4 2.3 0.8 4.6 0.4 33 12 24 300 -1.6 0 -1.2 -1.7 01/02/2006 19:00:00 1.6 0.8 3.4 0.4 1.5 0.7 3.8 0.4 1.3 0.7 3.4 0.4 37 14 37 300 -1.6 0 -1.4 -1.9 01/02/2006 19:10:00 1 0.6 2.6 0.4 0.9 0.6 2.6 0.4 0.8 0.5 2.3 0.4 47 18 64 300 -2.7 0.4 -1.9 -3.5 01/02/2006 19:20:00 0.9 0.5 2.3 0.4 0.8 0.4 1.9 0.4 0.7 0.3 1.5 0.4 47 17 19 300 -3.9 0 -3.5 -4.2 01/02/2006 19:30:00 0.9 0.6 2.6 0.4 0.8 0.5 2.3 0.4 0.6 0.3 1.5 0.4 40 13 32 300 -3.6 0 -3.5 -3.7 01/02/2006 19:40:00 0.8 0.5 2.3 0.4 0.7 0.4 2.3 0.4 0.5 0.3 1.9 0.4 33 11 40 300 -4.1 0.2 -3.7 -4.4 01/02/2006 19:50:00 1.8 0.5 3 0.4 1.6 0.5 2.6 0.4 1.1 0.4 1.9 0.4 28 11 23 300 -3.9 0.1 -3.7 -4.4 01/02/2006 20:00:00 0.7 0.4 1.9 0.4 0.7 0.4 1.9 0.4 0.5 0.2 1.1 0.4 48 12 49 300 -3.3 0.2 -2.8 -4.4 01/02/2006 20:10:00 1.5 0.9 3.8 0.4 1.4 0.8 3 0.4 1.2 0.6 3 0.4 42 9 36 300 -3.5 0.2 -3 -4.2 01/02/2006 20:20:00 3.3 0.6 4.9 1.5 3 0.5 4.2 1.5 2.1 0.5 3.8 1.1 34 8 24 300 -3.7 0 -3.5 -4.2 01/02/2006 20:30:00 4.2 0.4 5.3 3 3.7 0.5 5.3 2.6 2.7 0.6 4.6 1.1 22 6 30 300 -3.8 0.2 -3.3 -4.4 01/02/2006 20:40:00 4.3 0.4 5.3 3 3.9 0.5 5.7 2.6 2.9 0.6 4.6 1.9 19 6 20 300 -2.9 0.2 -2.6 -3.5 01/02/2006 20:50:00 3.8 0.6 4.9 1.9 3.4 0.7 4.9 1.5 2.6 0.6 4.2 1.1 18 7 21 300 -2.5 0.1 -2.4 -2.8 01/02/2006 21:00:00 3 0.5 4.2 1.5 2.7 0.5 4.2 1.5 2 0.5 3.8 0.7 21 7 20 300 -2.7 0 -2.4 -3.3 01/02/2006 21:10:00 2.8 0.6 4.2 0.7 2.4 0.6 4.2 0.4 1.8 0.6 3.4 0.4 23 9 33 300 -2.8 0 -2.6 -3 01/02/2006 21:20:00 2.5 0.5 3.4 1.1 2.2 0.5 3.4 0.7 1.6 0.5 3 0.4 35 12 34 300 -2.9 0 -2.8 -3 01/02/2006 21:30:00 3.1 0.6 4.9 1.5 2.7 0.6 4.2 1.1 2.2 0.6 3.8 0.7 30 8 29 300 -3.1 0 -2.8 -3.3 01/02/2006 21:40:00 3.8 0.5 5.3 2.3 3.4 0.5 4.9 1.9 2.5 0.5 4.6 1.5 21 8 26 300 -3.1 0 -2.8 -3.5 01/02/2006 21:50:00 3.5 0.5 4.6 2.3 3.1 0.5 4.6 1.9 2.4 0.5 4.2 1.1 23 7 13 300 -2.8 0 -2.6 -3 01/02/2006 22:00:00 4.1 0.6 5.7 2.6 3.7 0.7 5.7 1.9 2.8 0.6 4.6 1.5 19 6 22 300 -2.8 0 -2.6 -3.3 01/02/2006 22:10:00 4.1 0.6 5.7 1.9 3.9 0.7 5.7 1.9 3.1 0.6 4.9 1.5 15 8 16 300 -2.6 0 -2.6 -3 01/02/2006 22:20:00 4.1 0.6 5.7 2.3 3.7 0.7 5.7 1.5 3 0.7 4.9 1.5 20 8 17 300 -2.6 0 -2.6 -3 01/02/2006 22:30:00 4.1 0.8 5.7 2.3 3.6 0.8 5.7 1.5 2.8 0.7 5.7 1.1 21 10 14 300 -2.6 0 -2.6 -2.8 01/02/2006 22:40:00 4.1 0.7 5.7 1.9 3.6 0.8 5.7 1.1 2.8 0.7 4.9 1.1 21 10 35 300 -2.8 0 -2.6 -2.8 01/02/2006 22:50:00 4.3 0.7 6.1 2.6 3.8 0.8 5.7 2.3 3.1 0.8 4.9 0.4 19 10 20 300 -2.6 0 -2.6 -2.8 01/02/2006 23:00:00 3.9 0.6 5.3 2.3 3.5 0.7 5.3 1.5 2.8 0.7 4.9 1.5 20 9 16 300 -2.5 0 -2.4 -2.6 01/02/2006 23:10:00 3.9 0.6 5.3 2.3 3.4 0.7 5.7 1.5 2.7 0.6 4.9 1.5 23 9 27 300 -2.5 0 -2.4 -2.6 01/02/2006 23:20:00 4.1 0.7 5.3 2.3 3.5 0.7 4.9 1.9 2.7 0.6 4.6 1.5 27 10 13 300 -2.5 0 -2.4 -2.6 01/02/2006 23:30:00 4.3 0.6 6.1 3 3.8 0.7 6.1 1.9 3 0.7 5.3 0.7 22 10 15 300 -2.6 0 -2.4 -2.6 01/02/2006 23:40:00 3.8 0.7 5.7 1.9 3.3 0.8 5.3 1.5 2.7 0.8 4.9 1.1 22 10 20 300 -2.5 0 -2.4 -2.6 01/02/2006 23:50:00 3.3 0.7 5.3 1.9 2.9 0.7 4.9 1.1 2.3 0.6 4.2 1.1 26 11 30 300 -2.6 0 -2.6 -2.6 01/03/2006 00:00:00 3.9 0.6 5.3 2.3 3.5 0.7 5.3 1.9 2.9 0.6 4.6 1.5 26 11 19 300 -2.5 0 -2.4 -2.6 01/03/2006 00:10:00 3.7 0.8 6.1 1.9 3.3 0.7 5.3 1.5 2.6 0.7 4.6 1.1 29 11 30 300 -2.5 0 -2.4 -2.6 01/03/2006 00:20:00 3.5 0.7 5.7 1.9 3.1 0.7 5.3 1.5 2.6 0.6 4.6 1.1 31 10 24 300 -2.5 0 -2.4 -2.6 01/03/2006 00:30:00 3.3 0.6 5.3 1.9 2.8 0.7 4.6 1.5 2.4 0.6 4.9 0.7 28 8 30 300 -2.5 0.1 -2.4 -2.6 01/03/2006 00:40:00 3.1 0.6 4.6 1.5 2.6 0.6 4.6 1.1 2.2 0.5 3.8 0.7 25 11 20 300 -2.6 0 -2.4 -2.6 01/03/2006 00:50:00 3.6 0.6 5.3 1.5 3.2 0.7 4.9 1.5 2.4 0.7 4.6 0.4 20 11 17 300 -2.6 0 -2.6 -2.8 01/03/2006 01:00:00 3.9 0.8 6.1 1.9 3.4 0.8 5.3 1.5 2.8 0.8 4.6 1.1 25 12 33 300 -2.7 0 -2.6 -3 01/03/2006 01:10:00 4.1 0.7 6.8 2.3 3.6 0.8 6.5 1.9 2.9 0.8 4.9 0.7 26 10 36 300 -2.5 0 -2.4 -2.6 01/03/2006 01:20:00 4.2 0.8 6.5 2.3 3.7 0.8 6.1 1.9 3 0.7 4.9 0.7 23 12 22 300 -2.4 0 -2.1 -2.6 01/03/2006 01:30:00 4.6 0.8 6.8 2.6 4 0.8 6.5 2.3 3.3 0.8 5.3 0.7 25 10 41 300 -2.3 0 -2.1 -2.6 01/03/2006 01:40:00 4.6 0.7 6.5 3 4 0.8 6.1 1.5 3.4 0.7 5.3 1.5 26 10 28 300 -2.1 0 -2.1 -2.1 01/03/2006 01:50:00 4.3 0.8 6.5 2.3 3.8 0.8 6.1 1.5 3 0.8 5.3 1.1 29 11 24 300 -2.1 0 -2.1 -2.1 01/03/2006 02:00:00 4 0.8 6.1 2.3 3.6 0.8 6.5 1.5 2.9 0.8 6.1 0.7 30 14 6 300 -2.2 0 -2.1 -2.6 01/03/2006 02:10:00 4.8 0.9 6.8 2.3 4.2 0.8 6.1 1.9 3.5 1 6.1 1.1 28 11 25 300 -2.2 0 -2.1 -2.4 01/03/2006 02:20:00 4.1 1 6.1 1.5 3.6 1 5.7 1.1 2.9 0.8 4.9 0.7 30 13 23 300 -2.1 0 -2.1 -2.4 01/03/2006 02:30:00 3.9 0.9 6.1 1.9 3.4 0.9 6.1 1.1 2.7 0.8 4.9 0.4 27 13 41 300 -2.2 0 -2.1 -2.6 01/03/2006 02:40:00 4.7 0.8 6.8 2.6 4.2 0.8 6.8 1.9 3.5 0.7 5.7 1.5 24 10 18 300 -2.3 0 -2.1 -2.6 01/03/2006 02:50:00 4.5 0.8 6.8 2.6 4 1 6.5 1.9 3.3 0.8 5.3 1.1 23 11 13 300 -2.1 0 -2.1 -2.1 01/03/2006 03:00:00 3.1 0.8 5.3 1.5 2.7 0.8 5.3 0.7 2.3 0.8 4.2 0.7 34 14 65 300 -2.1 0 -1.9 -2.1 01/03/2006 03:10:00 4.2 0.8 6.5 2.6 3.7 0.8 6.1 1.5 3 0.7 4.9 1.5 30 12 22 300 -2.2 0 -2.1 -2.4 01/03/2006 03:20:00 4.9 1.1 9.1 1.9 4.3 1.1 8.4 1.1 3.8 0.8 6.8 1.5 28 12 34 300 -2 0 -1.9 -2.1 01/03/2006 03:30:00 5.1 1 7.2 2.6 4.5 0.9 7.2 2.3 3.8 0.9 6.5 1.5 29 12 31 300 -2 0 -1.9 -2.1 01/03/2006 03:40:00 5 0.9 7.2 2.6 4.3 0.8 6.5 1.9 3.7 0.8 6.1 1.9 25 11 15 300 -2 0 -1.9 -2.1 01/03/2006 03:50:00 4.8 0.9 6.8 2.6 4.3 0.9 7.2 1.9 3.5 0.8 6.1 1.1 26 11 30 300 -1.9 0 -1.9 -1.9 01/03/2006 04:00:00 4.8 0.9 6.8 2.6 4.2 0.9 6.5 2.3 3.6 0.7 5.7 1.9 27 11 34 300 -2 0 -1.9 -2.1 01/03/2006 04:10:00 5 0.8 6.8 3 4.4 0.8 6.5 2.3 3.7 0.7 6.1 1.9 24 10 22 300 -2.1 0 -1.9 -2.1 01/03/2006 04:20:00 4.3 0.8 6.5 2.3 3.8 0.8 6.1 1.9 3.3 0.8 5.3 1.5 24 11 24 300 -2.1 0 -1.9 -2.1 01/03/2006 04:30:00 3.7 0.7 6.5 1.9 3.3 0.8 5.7 1.5 2.8 0.6 4.6 1.5 22 12 33 300 -2.1 0 -1.9 -2.4 01/03/2006 04:40:00 4.1 0.7 5.7 2.3 3.6 0.7 5.3 1.9 2.9 0.7 4.9 1.1 23 10 18 300 -2.1 0 -1.9 -2.1 01/03/2006 04:50:00 3.9 0.7 6.1 2.3 3.4 0.8 6.1 1.5 2.9 0.6 5.3 1.5 28 10 19 300 -2 0 -1.9 -2.1 01/03/2006 05:00:00 3.3 0.8 5.7 1.5 2.9 0.9 5.3 0.4 2.3 0.8 4.9 0.4 34 12 27 300 -2.1 0 -1.9 -2.1 01/03/2006 05:10:00 2.4 0.9 4.2 0.4 2 0.9 4.2 0.4 1.3 0.8 3 0.4 38 27 46 300 -2.5 0.1 -2.1 -3 01/03/2006 05:20:00 2.3 0.6 4.2 0.7 1.9 0.8 4.2 0.4 1.2 0.6 3 0.4 39 18 54 300 -3.7 0.2 -2.8 -4.2 01/03/2006 05:30:00 2.1 0.7 4.6 0.7 1.8 0.8 4.2 0.4 1.2 0.5 3 0.4 41 17 10 300 -3.8 0 -3.5 -3.9 01/03/2006 05:40:00 2.8 0.8 4.9 1.5 2.4 0.8 4.2 0.7 1.9 0.7 3.4 0.4 34 15 14 300 -3.2 0.3 -2.6 -3.7 01/03/2006 05:50:00 4.6 1 6.8 2.3 4 0.9 6.5 1.9 3.4 0.8 6.1 1.9 26 12 18 300 -2.5 0 -2.1 -2.6 01/03/2006 06:00:00 5 0.9 8 1.9 4.4 1 7.2 1.9 3.5 0.9 6.1 1.1 23 11 23 300 -2.4 0 -2.1 -2.6 01/03/2006 06:10:00 5.4 0.9 6.8 2.6 4.9 1 6.8 2.3 4 0.8 6.1 1.9 19 10 17 300 -2.4 0 -2.1 -2.4 01/03/2006 06:20:00 5.1 0.8 6.8 3 4.7 0.8 6.8 2.3 3.9 0.9 6.5 2.3 18 9 22 300 -2.4 0 -2.1 -2.6 01/03/2006 06:30:00 4.9 0.9 6.8 2.3 4.4 1 6.5 1.5 3.6 0.8 6.1 1.9 19 9 22 300 -2.4 0 -2.1 -2.6 01/03/2006 06:40:00 5.3 1 7.6 2.6 4.7 1 7.2 2.3 4.1 1 7.2 1.5 22 9 21 300 -2.3 0 -2.1 -2.6 01/03/2006 06:50:00 5.5 0.9 7.2 2.6 4.8 1 7.2 1.9 4.1 0.8 6.5 1.5 24 11 9 300 -2.1 0 -2.1 -2.1 01/03/2006 07:00:00 4.8 0.8 6.8 2.6 4.2 0.8 7.2 2.3 3.6 0.8 6.1 1.1 23 10 36 300 -2.1 0 -2.1 -2.4 01/03/2006 07:10:00 4.7 0.8 6.5 2.3 4.1 0.8 6.1 1.9 3.3 0.8 6.1 1.5 24 11 33 300 -2.3 0 -2.1 -2.4 01/03/2006 07:20:00 4.9 0.8 7.2 3 4.3 0.8 6.8 2.3 3.5 0.8 5.3 1.5 23 10 29 300 -2.4 0 -2.1 -2.6 01/03/2006 07:30:00 4.5 0.8 6.5 1.9 4.1 0.9 6.8 1.9 3.3 0.8 6.1 1.1 21 10 20 300 -2.3 0 -2.1 -2.4 01/03/2006 07:40:00 4.6 0.8 6.8 2.3 4 0.8 6.1 1.9 3.4 0.7 4.9 1.5 26 12 33 300 -2.1 0 -2.1 -2.4 01/03/2006 07:50:00 4.7 0.8 7.2 2.3 4.1 0.9 6.8 1.5 3.5 0.8 6.1 1.5 30 11 34 300 -2.1 0 -2.1 -2.1